56178 Catalog

10205-Catalog 10205-Catalog 10205-Catalog 782520 Batch5 unilog cesco-content

56178-Catalog 56178-Catalog 56178-Catalog 782520 Batch12 unilog cesco-content

2014-11-11

: Pdf 56178-Catalog 56178-Catalog Batch12 unilog

Open the PDF directly: View PDF PDF.
Page Count: 112

Download56178-Catalog
Open PDF In BrowserView PDF
To be an

innovator,

first you have to
listen
to what
your
customers

say.

I

nnovation doesn’t happen by
chance. Yes, it takes experience...
dedication to quality... and a
willingness to think “outside the box.”
But if you’re going to continually
set industry standards, that thinking
had better reflect what your
customers expect.
Which is why at Dual-Lite,
innovation begins with listening
carefully to our customers.

About Our Products
All our latest products began with nationwide customer interviews to find out what you want and need...and
what you think. We then took this product-shaping feedback, factored in our own high standards for quality,
and developed products by which others are now measured. As you review our product offerings, you’ll see that
this strong tradition of excellence continues today with exit signs and emergency lighting that include the latest
advances and the highest level of performance.
About Our Quality
Quality is the key reason why Dual-Lite remains the industry’s most asked-for brand. You’ll see it in our construction, components, design and engineering, all of which combine to deliver the highest level of customer satisfaction, and the industry’s best safety record.
Number One Brand
It’s our unique “listen-to-learn” business philosophy that’s made Dual-Lite the industry’s Number One brand ...and
why our name still remains synonymous with life safety excellence after more than 65 years.

2

A Tradition Of Excellence
Sleek lines... low-profile silhouette... innovative design...
Only one line of life safety equipment fits this description
—the Liteforms® Collection by Dual-Lite.
Our unique styling is backed up by the substance of
high-quality, high-performance components and sturdy
construction features that helps ensure long-life, worryfree operation and lower maintenance expense. Plus,
with our extensive product offering, you’ll find a
Liteforms exit sign or emergency lighting unit for nearly
every commercial, industrial or institutional application.
That’s the LiteForms tradition of excellence
LiteForms, delivering the perfect solutions to all your life
safety product needs.

Collection

Focused On Value
For many, value equates to cost-effective products that
perform reliably.
For others, value means lowering transaction costs and
minimizing returns.
For everyone, value is simply having your expectations met
or exceeded every time.
Everything about Dual-Lite’s Clearview Collection is
focused on delivering the type of value and high output
performance that our customers have come to expect.
Additionally, Clearview Collection products share a “family”
style that results in a unified designer look when they are
installed together. With Clearview products, you can create
life safety lighting systems with eye appeal.
Value... Performance... Style...
That’s the Clearview difference.



Protection From Severe
Conditions
Whether your need is a vandalresistant exit sign, explosion-proof
emergency lighting, or units that can
withstand damp, exposed or hazardous
conditions, the solution is the Ultrex
line, from Dual-Lite.
Ultrex features products for almost
every severe condition you’ll
encounter.
Each Ultrex unit is designed to provide
unsurpassed, worry-free performance
and lower maintenance —
also lowering

costs.

Ultrex Choices

Dual-Lite offers a broad choice
of products for severe condition
applications, including:
Emergency Lighting Units
•	 EZ-2  Damp Series
• 	 LZ  Damp Series
• 	 LM Damp Series
• 	 N4X Series
•	 IPS Series
• 	 XPB Series
• 	 Lampak Series
Exit Signs
	 LX Series
• 	 LT Series
• 	 LN4X Series
• 	 Sempra SC Series
• 	 Sempra SC WL Series
• 	 Freedom LED Series
• 	 LEDS Series
•

Remote Lighting Heads
	 GNX Series
• 	 OMS Series
•

Features
•	Meets UL 924 standards for self-testing/self diagnostic

models.

Self-Testing/Self-Diagnostic
Electronics System

•	Provides automatic self-diagnostic monitoring and

testing of unit operation.
•	Automatically performs routine maintenance and

assures operational readiness at all times.
•	Monitors charger and lamp operation.
•	Routine discharge cycles insure optimum battery

performance and maximum useful life.
•	Automatic self-test every 28 days and extended

operation self-test every 6 months.
•	Automatic low voltage disconnect.
•	Automatic unit transfer in brownout conditions.
•	Automatic 15-minute retransfer delay (units).

Technologically advanced self-testing, self-diagnostic
electronics provide increased reliability and decreased
maintenance.
All Dual-Lite models ordered with the Spectron
option provide:
	 •	Visual indication of AC power status
	 • Visual Indication of all self-diagnostic test cycles
	 • Visual indication of unit malfunctions including:
			 • Battery disconnected
			 • Battery fault
      	 	 	 • Charger fault
      	 	 	 • Transfer fault
      	 	 	 • Lamp fault



•	Automatic AC lockout circuit.
•	Flashing LED indication of unit malfunction.
•	All detected malfunctions retained in memory until

corrected and retested.
•	Test switch allows a system check at any time.
•	Supports exit sign flashing options

Test Intervals

The Spectron self-testing/self-diagnostic system conducts
tests to verify proper operation continuously and on
monthly, and semiannual intervals. Manual tests may also
be performed at any time. A malfunction during any self
test will be indicated by the external status indicators .

Emergency
Lighting Units

LiteForms Emergency Lighting Units
LiteScape Series	
EZ-2 Series 	
LZ Series	
LZ (HC) Series	
LM Series	
EZ-2R Series 	
T-Grid Series	
EXT Series	
Lite2 Series	
Delite Series	
N4X Series	
AS Series	
IPS Series	
XPB Series	
Lampak Series	

Exit
Signs

Emergency
Lighting
Emergency
Lighting

Guaranteed Code Compliant Emergency Lights.................................................. 14, 15
Commercial Emergency Lights..................................................................................16
Designer Emergency Lights.................................................................................................. 17
High Capacity Designer Emergency Lights.......................................................... 18, 19
High Capacity Emergency Lights........................................................................ 20, 21
Recessed Emergency Lights.................................................................................................. 22
Recessed T-Grid Emergency Lights. ...........................................................................23
Recessed Gimbal Emergency Light............................................................................24
Emergency Lighting Square Units.................................................................... 25
Emergency Lighting Cylinder Units...........................................................................26
Harsh Environment Emergency Lights.......................................................................27
Industrial Emergency Lights.............................................................................. 28, 29
Wet Location Emergency Lights. ....................................................................... 30, 31
Explosion-Proof Emergency Lights..................................................................... 32, 33
Fluorescent Power Packs. .....................................................................34 to 38

LiteForms Exit Signs
LX Series 	
DK Series 	
LT Series	
NYXC Series	
SMC Series	
Sempra Series 	
Sempra MR Series 	
Sempra SC Series 	
Sempra SCWL Series 	
Sempra SERS Series 	
NYDC Series 	
LN4X Series	
Freedom LED Series	
LEDS Series	
NYX Series	
CMX Series	
LE Series	
LES Series	
NYE Series	
NYES Series	
DEX Series 	

Designer LED Exit Signs........................................................................................................ 40
AC Incandescent Exit Signs................................................................................................... 41
Designer Tandem Units..................................................................................... 42, 43
New York Tandem Units. .........................................................................................44
Tandem Units with Side Mounted Heads...................................................................45
Diecast LED Exit Signs.................................................................................................... 46, 47
Master/Remote Diecast LED Exit Signs......................................................................... 48, 49
Severe Conditions Diecast LED Exit Signs..................................................................... 50, 51
Wet Location Diecast LED Exit Signs.................................................................................... 52
Recessed Diecast LED Exit Signs........................................................................................... 53
New York Diecast LED Exit Signs......................................................................................... 54
Wet Location LED Exit Signs.....................................................................................55
Aluminum LED Exit Signs..................................................................................................... 56
Low-Profile Aluminum LED Exit Signs. ......................................................................57
New York LED Exit Signs..........................................................................................58
Chicago Exit Signs	...................................................................................................59
Recessed Mounting Edge-Lit LED Exit Signs................................................................ 60, 61
Surface Mounting AC Edge-Lit LED Exit Signs............................................................. 62, 63
New York Recessed Mounting Edge-Lit LED Exit Signs...................................................... 64
New York Surface Mounting Edge-Lit LED Exit Signs......................................................... 65
Special Wording Incandescent Exit Signs...................................................................66

Clearview Emergency Lighting Products
Remote Heads,
Fixtures and
Accessories

SlimLite Series 	
CV Series 	
CVEC Series	
CV3 Series 	
CVT Series	
CVD Series 	
CVER Series	

Fixed Lens  Emergency Lights...................................................................................68
Emergency Lights....................................................................................................69
High Capacity Emergency Lights...............................................................................70
LED Exit Signs........................................................................................................................ 71
Tandem Units..........................................................................................................72
Diecast LED Exit Signs........................................................................................................... 73
Recessed Mounting Edge-Lit LED Exit Signs....................................................................... 74

Remote Fixtures, Accessories & General Information

Inverter Power
Systems

Remote Heads and Fixtures . .................................................................................................76 to 78
Lamp Selector Guide ....................................................................................................................... 79
Voltage Drop Tables ....................................................................................................................... 80
Unit Accessories . .............................................................................................................................................81
National Electric Code ............................................................................................................................. 82, 83
NFPA 101 Life Safety Code . ................................................................................................................... 84, 85
Limited Warranty ............................................................................................................................ 86

Inverter Power Systems
Synchron Series Single-Phase Inverters ......................................................................................... 88 to 91
Spectron LSN Series Single-Phase Inverters ................................................................................92 to 101
Trident Series Three-Phase Inverters ...................................................................................................... 103 to 106
Auxiliary Transfer Switching Device  ...................................................................................................................... 107



The following guide provides a fast, easy method of selecting
products for most applications.  Refer to catalog pages for
additional product and ordering information.
Emergency Lighting Units
	 Catalog	 	
	
Page	
	
	 Number(s)	 Product Series	
	 14, 15	
LiteScape™ Series 	
	
		Commercial
Units
			
	
		
	
		
	
16	
EZ-2™ Series 	
Commercial
		
	
Units
	
		
			
		
	
	
	

17	
LZ Series 	
		Low-Profile
Halogen Lamp

	
Model	
Number 	

	
Unit	
Voltage	

Watts	
For	
11/2 Hrs.	

	
Battery	
Type	

Power	                           Warranty
Consumption	
	
	 Battery
(Max.)(1)	
Equipment	 	Full/Pro-Rata

LSC	
LSCN	
LSCI	
LSCNI	
GUARANTEED
CODE-COMPLIANCE

6	
6	
6	
6	

20	
20	
20	
20	

Lead-Calcium	
Nickel-Cadmium	
Lead-Calcium	
Nickel-Cadmium	

2 Watts	
2 Watts	
2 Watts	
2 Watts	

1 Years		
1 Years		
5 Years		
5 Years		

EZ-2	
EZ-2V	
EZ-2I	

4	
4	
6	

10.8	
10.8	
14.4	

Lead-Calcium	
“	
“	

15 Watts	
15 Watts	
15 Watts	

3 Years		 3/3 Years	
3 Years		 3/3 Years	
5 Years		 5/5 Years

Damp Location Model
EZ-2D	

4	

10.8	

Lead-Calcium	

15 Watts	

3 Years		

LZ2, LZ2D	
LZ15	

6	
6	

10	
15	

Lead-Calcium	
”	

3.5 Watts	
”	

1 Year		 1/5 Years
”		
”	

Standard Models
LZ30	
LZ35-12V	
LZ65	
LZ65-12V	
LZ20N	
LZ25N-12V	

6	
12	
6	
12	
6	
12	

30	
35	
65	
65	
20	
25	

Lead-Calcium	 14 Watts	
”	
”	
”	
”	
”	
”	
Nickel-Cadmium	 11.2 Watts	
”	
”	

1 Year		 1/5 Years
”		
”
”		
”
”		
”
3 Years		
1/9
”		
”

Damp Location Models	
LZ25D	
LZ30D-12V	
LZ55D	
LZ55D-12V	
LZ15ND	
LZ20ND-12V	

6	
12	
6	
12	
6	
12	

25	
30	
55	
55	
15	
20	

Lead-Calcium	 14 Watts	
”	
”	
”	
”	
”	
”	
Nickel-Cadmium	 11.2 Watts	
”	
”	

1 Year		 1/5 Years
”		
”
”		
”
”		
”
3 Years		
1/9
”		
”

6, 12	
6, 12	

—	
—	

—	
—	

—	
—	

Standard Models	
LM2	
LM16	
LM33	
LM40	
LM66	
LM80	
LM130	
LM40-12V	
LM66-12V	
LM80-12V	
LM130-12V	

6	
6	
6	
6	
6	
6	
6	
12	
12	
12	
12	

14.4	
16	
33	
40	
66	
80	
130	
40	
66	
80	
130	

Lead-Calcium	
“	
“	
“	
“	
“	
“	
“	
“	
“	
“	

15 Watts	
“	
“	
“	
“	
“	
“	
“	
“	
“	
“	

1 Year		 1/5 Years
“		
“
“		
“
“		
“
“		
“
“		
“
“		
“
“		
“
“		
“
“		
“
“		
“

Damp Location Models
LM28D	
LM34D	
LM56D	
LM68D	
LM112D	
LM34D-12V	
LM56D-12V	
LM68D-12V	
LM112D-12V	

6	
6	
6	
6	
6	
12	
12	
12	
12	

28	
34	
56	
68	
112	
34	
56	
68	
112	

Lead-Calcium	
“	
“	
“	
“	
“	
“	
“	
“	

15 Watts	
“	
“	
“	
“	
“	
“	
“	
“	

1 Year		 1/5 Years
“		
“
“		
“
“		
“
“		
“
“		
“
“		
“
“		
“
“		
“

1/5 Years	
1/9 Years
2/4 Years	
2/4 Years

3/3 Year

Units

	 18, 19	
LZ Series	
High
		
	 Capacity
Halogen Lamp
	
		Units
	
		
	
		
	
		
	
		
			
			• 	Choice of battery types
			• 	6- and 12-volt models
			• 	Capacities up to
				 65 watts
			
			

				
Remote Lighting Fixtures
			
			
Single Lamp Models	
			
Tandem Lamp Models	
	 20, 21	
LM Series	
Compact,
			Traditional
			Design Units
			
			
			
			
			
			
			
• 	Rugged metal housing
			
•		6- and 12-volt models
		
• 	Capacities up to 130

			 watts
			
• 	Lighting heads may be
			 top or side mounted
			
			
			
			
			
			
			

1 Year		
1 Year		

—
—

(1) Maximum power consumption specification shown for circuit-sizing purposes only.  Normal operating power requirements are significantly lower.  Consult factory for normal operating power
consumption ratings on specific models.



Quick Selector Guide
Emergency Lighting Units
	 Catalog	 	
	
Page	
	
	 Number(s)	 Product Series	

	
Model	
Number 	

	
Unit	
Voltage	

Watts	
For	
11/2 Hrs.	

	 20, 21	
LM Series				
Special
			Application
NiCad Battery Models
14.4	
			Models
LM15N	
6	
			
LM30N	
6	
30	
			
LM50N	
6	
50	
			
LM50N-12V	
12	
50	
			
LM100N-12V	
12	
100	
• 	Rugged metal housing

			
			• 	6- and 12-volt models
			• 	Capacities up to
	 100 watts
			

	
Battery	
Type	

Power	                           Warranty
Consumption	
	
	 Battery
(Max.)(1)	
Equipment	 	Full/Pro-Rata

Nickel-Cadmium	
“	
“	
“	
“	

15 Watts	
“	
“	
“	
“	

3 Years		 1/9 Years
“		
“
“		
“
“		
“
“		

City of Chicago Models
LM24CH	
LM36CH	
LM36CH-12V	

6	
6	
12	

24	
36	
36	

Lead-Calcium	
“	
“	

15 Watts	
“	
“	

1 Year		 1/5 Years
“		
“
“		
“

EZ-2R	
EZ-2RI	

6	
6	

10.8	
14.4	

Lead-Calcium	
“	

15 Watts	
15 Watts	

3 Years		 3/3 Years
5 Years		 5/5 Years

TG15	
TG30	
TG50-12V	
TG15N	
TG30N	
TG50N-12V	

6	
6	
12	
6	
6	
12	

15	
30	
50	
15	
30	
50	

Lead-Calcium	
”	
”	
Nickel-Cadmium	
”	
”	

15 Watts	
75 Watts	
”	
15 Watts	
75 Watts	
”	

3 Years		 3/3 Years
”		
”
”		
”
3 Years		 1/9 Years
”		
”
”		
”

EXT-122-EM-K	

6	

8	

Lead-Calcium	

15 Watts	

1 Year		 1/5 Years

	
25	
LITE2™ Series	
	
		Square
Units
	
		
			
	
		
			
	
		
	
		
urface, semi-recessed
				• 	Sand
fully-recessed models	
	
		

EDS	
EDS-2	
ERS	
ERS-3	
ERS-2-2	
ESS-I	
ESS-I-2	
ERS-I	
ERS-3I	
ERS-2I-2	

6	
6	
6	
6	
6	
6	
6	
6	
6	
6	

10	
14.4	
20	
30	
30	
10	
14.4	
20	
30	
30	

Lead-Calcium	
”	
”	
”	
”	
Lead-Calcium	
”	
”	
”	
”	

12 Watts	
”	
”	
”	
”	
12 Watts	
”	
”	
”	
”	

3 Years		 3/3 Years
”		
”
”		
”
”		
”
”		
”
5 Years		 5/5 Years
”		
”
”		
”
”		
”
”		
”

	
26	
DELITE® Series	
	
		Cylinder
Units
			
	
		

ESC-2-0	

6	

12	

Lead-Calcium	

15 Watts	

1 Years		 1/5 Years

	
	
	
	

N4X2	
N4X4	
N4X7	
N4X14	

6	
6	
6	
6	

15.6	
31.2	
50.4	
100	

Lead-Calcium	
”	
”	
”	

75 Watts	
”	
”	
”	

3 Years		 3/3 Years
”		
”
”		
”
”		
”

N4X7-12V	
N4X14-12V	

12	
12	

50.4	
100	

”	
”	

”	
”	

• 	Lighting heads may be
top or side mounted
• 	Chicago Models

	
	

22	
EZ-2R™ Series	
		Recessed
Mounting
Units

• 	Ceiling or wall mount

	
23	
T-Grid™ Series	
	
		Recessed
Troffer
			Units
			
	
		
			

• 	Suspended ceiling mount

	

24	

EXT™ Series	
Recessed
Gimbal
Unit

	
	

27	
N4X Series	
		Sealed, Harsh
Environment
		Unit
		
		
		

• 	Dust-tight, moisture
	 and corrosion resistant

”		
”		

”
”

(1) Maximum power consumption specification shown for circuit-sizing purposes only.  Normal operating power requirements are significantly lower.  Consult factory for normal operating power
consumption ratings on specific models.



Emergency Lighting Units
	 Catalog	 	
	
Page	
	
	 Number(s)	 Product Series	
	 28, 29	
AS Series	
	
		Traditional

	
Model	
Number 	
AS-80	
AS-130	

Voltage	
6	
6	

	
		
			
			

AS-180-12V	
AS-270--12V	
AS-360-12V	

12	
12	
12	

180	
270	
360	

”	
”	
”	

”	
”	
”	

”		
”		
”		

”
”
”

			
			• 	Maintenance-free      
batteries
			

AS-180-24V	
AS-270-24V	
AS-360-24V	

24	
24	
24	

180	
270	
360	

”	
”	
”	

”	
”	
”	

”		
”		
”		

”
”
”

	 28, 29	
ALC-X/EDC-X Series	
			Traditional
Units
			

ALC-X-30	
ALC-X-60	
ALC-X-100	

6	
6	
6	

78	
144	
162	

Wet-Cell	
Lead-Calcium	
”	

75 Watts	
”	
”	

12EDC-X-36S	
12EDC-X-60S	
12EDC-X-120S	

12	
12	
12	

200	
240	
350	

”	
”	
”	

”	
”	
”	

AS-75	
AS-145	
AS-210	

6	
6	
6	

75	
110	
145	

Wet-Cell	
Nickel-Cadmium	
”	

75 Watts	
”	
”	

	
		
	
		
			• 	Longest life,

12EDN-10S	
12EDN-18S	
12EDN-30S	

12	
12	
12	

48	
100	
150	

”	
”	
”	

”	
”	
”	

”		
”		
”		

”
”
”

	30, 31	
IPS Series	
			NEC Class I,

C1D2-6V36	
C1D2-6V72	

6	
6	

36	
72	

Pure-Lead	
“	

25 Watts	
“	

3		
“		

3/3
“

			
			• 	Suitable for

C1D2-12V36	
C1D2-12V72	

12	
12	

36	
72	

“	
“	

“	
“	

“		
“		

“
“

	32, 33	
XPB Series	
	
		ExplosionProof Units

XPB-75P	
12XPB-75P	

6	
12	

75	
75	

Pure-Lead	
”	

75 Watts	
”	

Units

			
			
			

• 	Wet-cell
	 lead-calcium batteries

	
	
	

28, 29	
AS/EDN Series	
		Traditional
Units
		

	 wet locations

Watts	
	
Power	                           Warranty
For	
Battery	
Consumption	
	
	 Battery
11/2 Hrs.	
Type	
(Max.)(1)	
Equipment	 	Full/Pro-Rata
80	
Lead-Calcium	 75 Watts	
1 Year		 1/5 Years
130	
”	
”	
”		
”

1 Year		 1/9 Years
”		
”
”		
”
”		
”		
”		

”
”
”

Note: 12EDC-X models supplied
without lighting heads.

	 wet-cell nickel-cadmium Note: 12EDN models supplied
batteries
without lighting heads.

Division 2
Units

	
Unit	

1 Year		 1/14 Years
”		
”
”		
”

3 Years		 3/3 Years
”		
”

• 	NEC Class I
	 and II operation
• 	Unit mounted and
remote fixtures
(1) Maximum power consumption specification shown for circuit-sizing purposes only.  Normal operating power requirements are significantly lower.  Consult factory for normal operating power
consumption ratings on specific models.

Fluorescent Power Packs
	 Catalog	 	
	
Page	
	
	 Number(s)	 Product Series	
34	
LAMPAK® Series	
	
	
		Fluorescent
Packs
			
			• 	Models
standard
					 for
fluorescent lamps
			
		
	

	
Model	
Number 	
UFO-3AW	
UFO-4W	
UFO-5W	
UFO-5AW	
UFO-6W	
UFO-6WI	
UFO-6W-CLD	

	35	
LAMPAK® Series	
			Fluorescent
Packs

UFO-7W	
UFO-7WI	

• 	High lumen output
models
	



Operates	
Lamp	
Type	
Std. Fluor.	
Std. Fluor.	
Std. Fluor.	
Std. Fluor.	
Std. Fluor.	
Std. Fluor.	
Std. Fluor.	

Rating	
	
I n	
Battery	
Lumens	
Type	
350-450	 Nickel-Cadmium	
500-600	
”	
600-700	
”	
600-700	
”	
1100-1400	
”	
1100-1400	
”	
600-750	
”	

Std. Fluor.	 1450-3500	Nickel-Cadmium	
Std. Fluor.	 1800-3500	
“	

Number	                           Warranty
Of Lamps	
	
	 Battery
Operated	
Equipment	 	Full/Pro-Rata
1	
1 Year		 1 Year
1	
”		
”
1	
”		
”
1 or 2	
”		
”
1 or 2	
”		
”
1 or 2	
”		
”
1 or 2	
”		
”
1 or 2	
1 or 2	

1 Year		
“		

1 Year
“

Quick Selector Guide
Fluorescent Power Packs
	 Catalog	 	
	
Page	
	
	 Number(s)	 Product Series	

	
Model	
Number 	

Operates	
Lamp	
Type	

Rating	
I n	
Lumens	

	
Battery	
Type	

Number	                           Warranty
Of Lamps	
	
	 Battery
Operated	
Equipment	 	Full/Pro-Rata

	36	
LAMPAK® Series	
UFO-12W	
	
		Fluorescent
	
Packs
				
• 	For compact
	 fluorescent lamps
				

13 to 42W	 300-750	 Nickel-Cadmium	
Compact
Fluor.
Lamps

1 or 2	

1 Year		

1 Year

LAMPAK® Series	
UFO-LP1	
	37	
			Fluorescent
UFO-LP2	
Packs
				
• 	For low-profile

T5 and T8	 390-700	 Nickel-Cadmium	
Fluor.	
650-1325	
“	
Lamps

1	
1	

1 Year		
“		

1 Year
“

	38	
LAMPAK® Series	
			HID Back-up
Ballast
			• 	For metal-

Metal-	 20 to 30%	Nickel-Cadmium	
Halide	
Normal	
“	
HID Lamps	 Output	
“	

1	
1	
1	

1 Year		
“		
“		

1 Year
“
“

	 fluorescent fixtures
	

UFO-MH175	
UFO-MH250	
UFO-MH400	

	 halide HID lamps

Exit Signs
	 Catalog	 	
	
Page	
	
	 Number(s)	 Product Series	
	
	
	

	
AC Lamp	
Type	

	
AC Lamp	
Wattage	

	
DC Lamp	
Type	

	
Battery	
Type	

Power	                            Warranty
Consumption	
	
	 Battery
(Emerg. Max.)(1)	
Equipment	 	Full/Pro-Rata

40	
LX Series	
LED	
Red – 2.6W	
LED	
Nickel-Cadmium	
3.8 Watts	
Thermoplastic
			
Green – 2.1W 				
LED Exit Signs
							

	
	

5 Years		 1/9 Years	

• 	All models
	 Damp Location Listed

	41	
DK Series	
Incandescent	
15W (2)	
—	
—	
30 Watts	
Thermoplastic
		
						
Incandescent
	
							
Exit Signs

3 Years		
Excluding	
AC Lamps

—	

	42, 43	
LT Series	
LED	
Red – 2.6W	
Halogen	 Lead-Calcium	
5.0 Watts	
5 Years		 1/5 Years
Combination
	
			
Green
–
2.1W
	
and			
Emergency
					
LED				
Unit/LED Exit
Signs

• 	Damp Location  
	 and Remote
	 Capacity models

	
44	
NYXC Series	
LED	
Red –3.5W	
LED	
Lead-Calcium	
7.0 Watts	
Combination
				
Green
–
3.0W
				
Emergency
								
Unit/LED Exit

5 Years		 1/5 Years

Signs

	

• 	Meets NY City
							
	 requirements

	
45	
SMC Series	
LED	
Red – 2.6W	
LED	
Lead-Calcium	
12 Watts	
Combination
				
Green – 2.1W 				
Emergency
								
Unit/LED Exit

3 Years		 1/5 Years

Signs

	
	

							
• 	Low-profile
	 side mounted
	 lighting heads

(1) Maximum power consumption specification shown for circuit-sizing purposes only.  Normal operating power requirements are significantly lower.  Consult factory for normal operating power
consumption ratings on specific models.



Exit Signs
	 Catalog	 	
	
Page	
	
	 Number(s)	 Product Series	

	
AC Lamp	
Type	

	
AC Lamp	
Wattage	

	
DC Lamp	
Type	

	
Battery	
Type	

Power	                             Warranty
Consumption	
	
	 Battery
(Emerg. Max.)(1)	
Equipment	 	Full/Pro-Rata

	 46, 47	
Sempra® Series	
LED	
Red – 2.6W	
LED	
Nickel-Cadmium	
3.8 Watts	
Cast Aluminum
				
Green – 2.1W 				
LED Exit Signs
								
	
							

5 Years		 1/9 Years
(Lifetime on
LED strip)

• 	Lifetime warranty
	 on LED lamp strip

Sempra® MR Series	
LED	
Red – 2.6W (2)	
LED	
Nickel-Cadmium	
3.8 Watts	
	 48, 49	
Master/Remote
				
Green – 2.1W (2)				
Cast Aluminum
LED Exit Signs
								

5 Years		 1/9 Years
(Lifetime on
LED strip)

• 	Supplied as
	 2-sign sets

	

• 	Low-profile
	 Remote exit
• 	Lifetime warranty
	 on LED lamp strip

Sempra® SC Series	
LED	
Red – 2.6W	
LED	
Nickel-Cadmium	
3.8 Watts	
	50, 51	
Severe Conditions
				
Green – 2.1W 				
Cast Aluminum
								
LED Exit Signs

5 Years		 1/9 Years
(Lifetime on
LED strip)

• 	Lifetime warranty
	 on LED lamp strip

	52	
Sempra® SCWL Series	
LED	
Red – 2.6W	
LED	
Nickel-Cadmium	
3.8 Watts	
Wet Location Cast
				
Green – 2.1W 				
Aluminum LED
								
Exit Signs

5 Years		 1/9 Years
(Lifetime on
LED strip)

• 	Completely
	 sealed and
	 gasketed
• 	Lifetime warranty
	 on LED lamp strip

	
53	
Sempra® SERS Series	
LED	
Red – 2.6W	
LED	
Nickel-Cadmium	
3.8 Watts	
Recessed Cast
	
			
Green – 2.1W 				
Aluminum LED
								
Exit Signs
	
	

5 Years		 1/9 Years	
(Lifetime on			
LED strip)

							
	
• 	Lifetime warranty
	 on LED lamp strip

	
54	
NYDC Series	
LED	
Cast Aluminum
				
LED Exit Signs

Red – 2.5W	
LED	
Nickel-Cadmium	
3.5 Watts	
				

5 Years		 1/9 Years

• 	Meets NY City
	 requirements

	
							
	55	
LN4X Series	
LED	
Red – 2.6W	
LED	
Nickel-Cadmium	
3.8 Watts	
5 Years		 1/9 Years	
Wet Location
	
			
Green
–
2.1W
							
LED Exit Signs
								
• 	Suitable for damp, wet
and corrosive environments

Single Face
	56	
Freedom® LED Series	
LED		
LED	
Lead-Acid	
7.7 Watts	
5 Years		 1/4 Years
Red – 4.5W
Aluminum LED
	
			
				
Exit Signs
Green – 4.7W
									
Double Face
Red – 6.8W
Green – 6.7W
	

• 	Up to 12 hours of
emergency operation

							
• 	All models
	 Damp Location Listed

(1) Maximum power consumption specification shown for circuit-sizing purposes only.  Normal operating power requirements are significantly lower.  Consult factory for normal operating power
consumption ratings on specific models.

10

Quick Selector Guide
Exit Signs
	 Catalog	 	
	
Page	
	
	 Number(s)	 Product Series	

	
AC Lamp	
Type	

	
AC Lamp	
Wattage	

	
DC Lamp	
Type	

	
Battery	
Type	

Power	                            Warranty
Consumption	
	
	 Battery
(Emerg. Max.)(1)	
Equipment	 	Full/Pro-Rata

	
57	
LEDS Series	
LED	
Red – 3.2W	
LED	
Nickel-Cadmium	
3.3 Watts	
Low-Profile  
				
Green – 2.9W 				
Aluminum LED
								
Exit Signs
	

							
• 	All models
	 Damp Location Listed

NYX Series	
LED	
Red – 2.4W	
LED	
Nickel-Cadmium	
3.5 Watts	
	
58	
New York City
				
				
LED Exit Signs
								
	

5 Years		 1/9 Years

							
• 	Meets NY City
	 requirements

	
59	
CMX Series	
			Chicago
Exit Signs
			

	

5 Years		 1/9 Years

Incandescent	 Incand.– 20W (2)	 5W (2)	
Lead-Calcium	
Incand.– 50W	
or	
Fluor.– 9W (2) 			
Fluor.– 28W 	
Fluorescent					

5 Years		 1/9 Years

• 	City of Chicago

							
	 approval No.
	 9823

Single Face
	 60, 61	
LE Series	
LED		
LED	
Nickel-Cadmium	
3.8 Watts	
Recessed Edge-Lit
Red – 2.2W
				
				
LED Exit Signs
Green – 2.5W
								

5 Years		 1/9 Years

Double Face
Red – 3.4W
							
Green – 4.0W
• 	Choice of six
• 	Universal recess
rough-in kit

	

	 decorator finishes

Single Face
	 62, 63	
LES Series	
LED		
—	
—	
Red – 2.2W
Surface Mount
							
Edge-Lit  LED
Green – 2.5W
AC Exit Signs
• 	Wall-, ceiling- and
end-mount models

4.0 Watts	

5 Years		 1/9 Years

Double Face
Red – 3.4W
Green – 4.0W

• 	Choice of six           

decorator finishes
	
NYE Series	
LED	
Red – 3.2W	
LED	
Nickel-Cadmium	
4.0 Watts	
	
64	
NYC Recessed
				
				
Edge-Lit LED Exit
								
Signs

5 Years		 1/9 Years

• 	Ceiling or wall
	 recess installation

	

							
• 	Meets NY City requirements

NYES Series	
LED	
Red – 3.2W	
—	
Nickel-Cadmium	
	
65	
NYC Surface
							
Mount Edge-

4.0 Watts	

5 Years		 1/9 Years

	
66	
DEX Series	
Incandescent	
15W (2)	
3.7W (2)	 Lead-Calcium	
35 Watts	
Special
Wording
Incandescent			
		
			
Incandescent
	
							
Exit Signs

3 Years		 1/5 Years	
Excluding	
AC Lamps

Lit  LED Exit
Signs

• 	Wall-, ceiling- and
end-mount models
• 	Meets NY City requirements

(1) Maximum power consumption specification shown for circuit-sizing purposes only.  Normal operating power requirements are significantly lower.  Consult factory for normal operating power
consumption ratings on specific models.

11

Quick Selector Guide
Emergency Lighting Products
	 Catalog	 	
	
Page	
	
	 Number(s)	 Product Series	
	
	

68	
SlimLite Series 	
		Contemporary
Unit

	
69	
CV Series	
Designer
		
	
Units
	
		
	
		
	
		• 	Standard and damp
location models
			
			
			
	
	
	
	
	

70	
CVEC Series	
		Commercial
Units
		• 	6- and 12-volt
	
		 models
		• 	Capacities up to 100

watts
• 	Lighting heads may be
top or side mounted

	 Catalog	 	
	
Page	
	
	 Number(s)	 Product Series	
	
	
	

	
Model	
Number 	
SL1, SL1-V	

	
Unit	
Voltage	

Watts	
For	
11/2 Hrs.	

	
Battery	
Type	

Power	                          Warranty
Consumption	
	
	 Battery
(Max.)(1)	
Equipment	 	Full/Pro-Rata

6	

12	

Lead-Calcium	

3.5 Watts	

1 Year		 1/5 Years

Standard Models
CV2	
CV3	
CV5	
Damp Location Models	
CV2D	
CV3D	
CV5D	

6	
6	
6	

12	
18	
30	

Lead-Calcium	
”	
“	

4 Watts	
”	
14 Watts	

1 Year		 1/5 Years
”		
”
“		
“

6	
6	
6	

12	
18	
30	

Lead-Calcium	
”	
“	

4 Watts	
”	
14 Watts	

1 Year		 1/5 Years
”		
”
“		
“

CVEC15	
CVEC30	
CVEC50	
CVEC50-12V	
CVEC100-12V	

6	
6	
6	
6	
6	

15	
30	
50	
50	
100	

Lead-Calcium	
”	
“	
”	
“	

9 Watts	
9 Watts	
20 Watts	
14 Watts	
39 Watts	

1 Year		 1/5 Years
”		
”
“		
“
”		
”
“		
“

	
AC Lamp	
Type	

	
AC Lamp	
Wattage	

	
DC Lamp	
Type	

	
Battery	
Type	

Power	                            Warranty
Consumption	
	
	 Battery
(Emerg. Max.)(1)	
Equipment	 	Full/Pro-Rata

71	
CV3 Series	
LED	
Red – 2.6W	
LED	
Nickel-Cadmium	
3.8 Watts	
Thermoplastic
			
Green – 2.1W 				
LED Exit Signs
							

5 Years		 1/9 Years	

	
72	
CVT Series	
LED	
Red – 2.6W	
Halogen	 Lead-Calcium	
5.0 Watts	
Combination
	
			
Green
–
2.1W
	
and			
Emergency
					
LED		
	
Unit/LED Exit
Signs
	
							

5 Years		 1/9 Years
Excluding
AC Lamps	

	

	
73	
CVD Series	
LED	
Cast Aluminum
				
LED Exit Signs

Red – 2.6W	
LED	
Nickel-Cadmium	
3.8 Watts	
Green – 2.1W 				

5 Years		 1/9 Years	

									
	
74	
CVER Series	
LED	
Red –2.5W	
LED	
Nickel-Cadmium	
5.2 Watts	
Recessed
				
Green – 3.0W 		
Mount Edge		
Lit LED Exit
Signs
								

5 Years		 1/9 Years

(1) Maximum power consumption specification shown for circuit-sizing purposes only.  Normal operating power requirements are significantly lower.  Consult factory for normal operating power
consumption ratings on specific models.

Inverter Power Systems
	 Catalog	 	
	
Page	
	
	 Number(s)	 Product Series	
	 88 to 91	
	 92 to 101	
	 103 to 104	
	 105 to 106	

12

	
	
	

Synchron Series		
Spectron LSN		
Trident TRX Series		
Trident TRN Series		

	
	
	

	
	
	

	
	
	

	
	
	

				
				
				
				

	
System	
Type	

	 System
	 Output
	 Capacities

Single Phase		400 to 2100VA
Single Phase		1.0 to 17.5kVA
Three Phase		 10 to 30kVA
Three Phase		30 to 130kVA	

Emergency Lighting Units
LiteScape Series	
EZ-2 Series 	
LZ Series	
LZ (HC) Series	
LM Series	
EZ-2R Series 	
T-Grid Series	
EXT Series	
Lite2 Series	
Delite Series	
N4X Series	
AS Series	
IPS Series	
XPB Series	
Lampak Series	

Guaranteed Code Compliant Emergency Lights................. 14,

15

Commercial Emergency Lights. ............................................... 16
Designer Emergency Lights.............................................................17
High Capacity Designer Emergency Lights......................... 18,

19
21
Recessed Emergency Lights.............................................................22
Recessed T-Grid Emergency Lights........................................... 23
Recessed Gimbal Emergency Light........................................... 24
Emergency Lighting Square Units. ..................................... 25
Emergency Lighting Cylinder Units.......................................... 26
Harsh Environment Emergency Lights...................................... 27
Industrial Emergency Lights............................................. 28, 29
Wet Location Emergency Lights. ...................................... 30, 31
Explosion-Proof Emergency Lights.................................... 32, 33
Fluorescent Power Packs.............................................. 34 to 38
High Capacity Emergency Lights....................................... 20,

13

LiteScape

Commercial Emergency Light
Features

•	 Factory guaranteed NFPA-101
code-compliant illumination
W
Field
adjustable 3 ft. x 40 ft. or
•	
NE
6 ft. x 30 ft. egress illumination
patterns
•	 SurePath® technology delivers
bright, continuous illumination
•	 Low-profile silhouette
•	 Fast, easy installation
•	 High-output, 6 volt, 10-watt
halogen lamps
•	 Impact resistant, UV stable
polycarbonate construction
GUARANTEED CODE•	 Unit housing is paintable
COMPLIANT ILLUMINATION
•	 Lead-acid or nickel-cadmium
rdering nformationbattery models

O

I

20W

•	 Universal 120/277VAC operation
•	 AC lockout
•	 Available with Spectron®
self-testing/self-diagnostic
electronics with time-delay relay
(TDR) standard
•	 Low-voltage battery disconnect
•	 Test switch and AC-On indicator
•	 Temperature range:
	 Lead-acid models = 	20°C to 30°C 	
	
(68°F to 86°F)
	 Nickel-Cadmium models = 0°C to 40°C 	
	
(32°F to 104°F)
•	 UL 924 Listed (Emergency Lighting)
•	 UL Damp Location Listed
	 (Nickel-Cadmium models only)

Ordering Information
				
Nickel-Cadmium
Standard Model	
Nickel-Cadmium Model	
Spectron Self-Testing Model	 Spectron Self-Testing Model
ptions
(Add suffix to
model)
ccessories
(Order
 Separately)
	
LSC	
LSCN	
LSCI	
LSCNI

O

A

Options
-24K	
-AA	

(Add

suffix to model)

220/240VAC, 60Hz. operation
Audible alarm (1)

(1)  	For use with LSCI and LSCNI self-testing/self-diagnostic 	
	 models only.
Patented reflector design
produces bright, evenly illuminated
“SurePath™” egress lighting pattern

SurePathTM Technology

The heart of LiteScape’s SurePath technology is the patent pending reflector design created exclusively for Dual-Lite by
Breault Research Organization, the company selected to correct the optics for the Hubble space telescope. This unique
reflector design coupled with the unit’s two high-output, 10-watt halogen lamps provide an incredibly bright and
evenly distributed illumination pattern. Additionally, a user-selectable reflector adjustment allows a choice of the 3’ or
6’ wide SurePath illumination patterns. The long, broad and even nature of the SurePath illumination pattern makes it
the optimum method of lighting interior paths of egress during emergency conditions.

Dimensions

81/2”

Housing is field paintable
to match wall decor.

11”

14

1 2”

3/

	

LiteScape
The LiteScape Performance Guarantee
Dual-Lite guarantees the LiteScape unit will fully meet the 2003 edition of the NFPA 101
Life Safety Code emergency lighting requirements by providing an average of one footcandle of
illumination along the path of egress as defined in the illustration below.
Center to Center Mounting Information

7.5 ft.

3-Foot Wide Standard Illumination Path Setting = 40 Foot Centers
6-Foot Wide Optional Illumination Path Setting = 30 Foot Centers
NOTE:	
	
	
	

The LiteScape unit must be installed per factory instructions provided
and properly maintained. In addition, the pathway to be illuminated
must meet the minimum surface reflectance values shown at right to
qualify for guaranteed illumination performance.

Minimum Reflectance Values Required:
Ceiling: 80% Walls: 50% Floor: 20%

The LiteScape Performance Guarantee applies solely to units mounted 7.5 feet above the floor surface.  For information on lighting performance
at other mounting heights, refer to LiteScape Series Mounting Guide on the LiteScape product page in the Dual-Lite web site’s on-line catalog.
The LiteScape Performance Guarantee is subject to all conditions as outlined in the Product Warranty Statement on the Dual-Lite public web site
(www.dual-lite.com) and applies only to the installation’s initial emergency lighting inspection by the authority having jurisdiction.  

Photometrics
3-Foot Standard Illumination Path Setting (40-Foot Mounting Centers)

6-Foot Optional Illumination Path Setting (30-Foot Mounting Centers)

1) 	 Photometric illustrations based on data provided by Independent Testing Laboratories (ITL), Boulder, Colorado.
2) 	 Photometrics shown based on 7.5-foot mounting height and minimum 80-50-20 reflectance values.
3) 	 The white rectangular area in photometric illustrations represents normal center to center SurePath egress illumination pattern provided.

Independent Verification
The photometric data shown above was generated and verified by Independent Testing Laboratories (ITL) of Boulder,
Colorado. LiteScape IES photometric files can be downloaded from the LiteScape product page at www.dual-lite.com.
LiteScape illumination data has also been incorporated into the Hubbell LitePro® lighting design application software.

15

EZ-2

Commercial Emergency Lights
Features

An
Damp

Severe Conditions Product

•	 Easy to install
•	 Compact, low-profile design
•	 Flame-rated, UV-stable
thermoplastic housing
•	 Textured, bright white finish
•	 Universal mounting plate
•	 Glare-free, adjustable lampheads
•	 Maintenance-free battery
•	 Universal 120/277VAC operation
•	 Low power consumption
•	 Fully-automatic charger
•	 AC lockout

10.8W, 14.4W

•	 Low-voltage battery disconnect
•	 Transformer isolation protection
•	 Test switch and AC-On light
•	 Available with Spectron® selftesting/self-diagnostic electronics
	 with time-delay relay
	 (TDR) standard
•	 Damp location model available
•	 Temperature range: 	20°C to 30°C
		
(68°F to 86°F)
Damp location EZ-2D: 0°C - 40°C
		
(32°F to 104°F)
•	 UL 924 Listed

(Damp Location Model EZ-2D)

Ordering Information
	Standard Model	
	
EZ-2 	

Options
-A21	

Damp Location Model	
EZ-2-D	

(Add

Voltmeter Model	
EZ-2-V	

Spectron Self-Testing Model
EZ-2I

Accessories

suffix to model)

(Order Separately)

Vandal resistant shield
VRS	
WGEL	 Wire guard

Auxiliary 2-conductor AC line cord (120V only)

Product Selector Guide
Electrical

		

	
	
	

 Base	

Catalog	
Number	

Output Watts	
Output	 1.5	
2	
3	
4	
Volts	 Hours	 Hours	 Hours	 Hours	

	

   AC Input	
	
	
Standard	  Remote
Volts	     Amps	   Watts	
Lamp	 Capability
	

	
EZ-2, EZ-2-D 	
6	
10.8	
--	
--	
-	 and EZ-2-V						

120	

.080	

8.4 	

277	

.030	

8.8	

	

120	

.080	

8.4 	

277	

.030	

8.8

14.4	
--	
--	
-	
EZ-2I*	
6	
							

5.4W	

No

7.2W	

No

* Includes Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard

Photometrics

Horizontal Isofootcandle Distribution
6 Volt, 5.4 Watt SBT Lamp 	

6 Volt, 7.2 Watt SBT Lamp

Dimensions
14” (35.5 cm)
5” (12.7 cm)

5” (12.7 cm)

16

Designer Emergency Lights
Features
•	 Easy to install
•	 Flame-rated, UV-stable
thermoplastic housing
•	 White or black finishes
•	 Slim, low-profile snap-together
design
•	 Standard and damp location 		
models
•	 Low profile, adjustable lampheads
•	 High-output halogen lamps
•	 Clear glass protective lamp lens
•	 Matching remote fixtures
•	 120/277VAC operation standard
•	 Fully-automatic charger

LZ

10W

•	 Maintenance-free battery
•	 90 minute operation
•	 Low-voltage battery disconnect
•	 Transformer isolation protection
•	 Test switch and AC-On light
•	 Available with Spectron® selftesting/self-diagnostic electronics
with time-delay relay
	 (TDR) standard
•	 Temperature range: 	 20°C to 30°C
		
(68°F to 86°F)
Damp location model:	10°C to 40°C
		
(50°F to 104°F)
•	 UL 924 Listed

Ordering Information
See Product Selector Guide below for available models

Matching remote
lighting head
Outdoor lighting
head

Options

(Add

Accessories

suffix to model)

I		
-B 		
-V 	
-24K	
-A21	

Spectron self-testing/self-diagnostic electronics
Black finish
Voltmeter	
220-240VAC, 60 Hz. operation
Auxiliary 2-conductor line cord (120V only) (1)

-A31	

Auxiliary 3-conductor line cord (120V only) (2)

(3)

VRS 			
WGLZ 			
PMLZTW 		
PMLZTB 		
LZRSW0605 	
LZRSB0605 	
OMSSW0605 	
				
OMSSB0605 	
				

(1)	 Not for use with LZ15 model.
(2)	 For use with LZ15 model only.
(3)	 Not available with LZ2 model.

(Order Separately)

Vandal resistant shield
Wire guard
121­­/2” Pendant mounting kit - white
121/2” Pendant mounting kit - black
Matching remote lighting head - white
Matching remote lighting head - black
Outdoor lighting head - 6 Volt, 5 Watt 	
sealed beam type lamp - White finish
Outdoor lighting head - 6 Volt, 5 Watt 	
sealed beam type lamp - Black finish

Product Selector Guide
	

	

	
	
       	
	
	
	

Base	

	

Catalog	
Numbers	

Output	
Volts	

LZ2	
LZ2D* 	
LZ15	

6	
6	
6	

Electrical
	
                  O
utput Watts
1.5	
2	
3	
4	
Hours 	
Hours 	
Hours	
Hours	
10	
10 	
15	

--	
-- 	
12	

--	
-- 	
--	

--	
--	
--	

Standard	
Lamp	

Remote
Capability

5W Hal.	
5W Hal.	
5W Hal.	

No
No
Yes

Photometrics

Dimensions

High-Output Halogen Lamp
Also available in black finish

Horizontal Isofootcandle Distribution

3 5/8” (9.2cm)

17

LZ

Designer Emergency Lights
Features

High Capacity

An
Severe Conditions Product Line

Damp

(Damp Location Models)

•	 Easy to install
•	 Capacities up to 65 watts
•	 6- and 12-volt models
•	 Flame-rated, UV-stable
thermoplastic housing
•	 White or black finishes
•	 Snap-together design
•	 Standard and damp location 		
models
•	 Low profile lampheads
•	 High-output halogen lamps
•	 Clear glass protective lamp lens
•	 Matching remote fixtures
•	 120/277VAC operation standard

15W to 65W

•	 Fully automatic charger
•	 Choice of maintenance-free battery
types
•	 Low-voltage battery disconnect
•	 Transformer isolation protection
•	 Test switch and AC-On light
•	 Available with Spectron® selftesting/self-diagnostic electronics
	 with time-delay relay
(TDR) standard
•	 Temperature range: 	 20°C to 30°C
		
(68°F to 86°F)
Damp location model:	10°C to 40°C
		
(50°F to 104°F)
•	 UL 924 Listed

Ordering Information
See Product Selector Guide for available models

Options
I		
-B 		
-V 	
-10W	
-0		
-24K	
-A31	

(Add

Accessories

suffix to model)

Spectron self-testing/self-diagnostic electronics
Black finish
Voltmeter	
			
10-watt halogen lamps (1)
Unit supplied without lampheads
220-240VAC, 60 Hz. operation 	 	
Auxiliary 3-conductor line cord (120V only)

(1)	 Available on units with capacities of 20 watts or more.

(Order Separately)

VRS 			 Vandal resistant shield
WGEL			 Wire guard
LZRSW0605	 Matching remote lighting head - white
LZRDSB0605 	Matching remote lighting head - black
OMSSW0605 	Outdoor lighting head - 6 Volt, 5 Watt 	
				 sealed beam type lamp - White finish
OMSSB0605 	 Outdoor lighting head - 6 Volt, 5 Watt 	
				 sealed beam type lamp - Black finish
OMSSW1205 	Outdoor lighting head - 12 Volt, 5 Watt 	
				 sealed beam type lamp - White finish
OMSSB1205 	 Outdoor lighting head - 12 Volt, 5 Watt 	
				 sealed beam type lamp - Black finish

Outdoor
Lighting Heads
Matching
Remote Lighting
Heads

Also available in black finish

Matching Remote Fixtures

Photometrics

High-Output Halogen Lamp
Horizontal Isofootcandle Distribution
Standard 5W MR-16 Lamp 	

	

Optional 10W MR-16 Lamp

A complete line of 6- and 12-volt matching remote fixtures
in single and tandem lamp configurations is available for use
with LZ Series high-capacity units or any other 6- or 12-volt DC
emergency lighting remote power sources.
All remote fixtures are offered in black and white textured
finishes with a choice of 5- or 10-watt halogen lamps.
			 White	 	
	 Black
	

18

Single	

	 Tandem	

Single	

	 Tandem	

Volts	 Watts

		 LZRSW0605		 LZRDW0605	

LZRSB0605		 LZRDB0605	

6	

5

		 LZRSW0610		 LZRDW0610	

LZRSB0610		 LZRDB0610	

6	

10

		 LZRSW1205		 LZRDW1205	

LZRSB1205		 LZRDB1205	

12	

5

		 LZRSW1210		 LZRDW1210	

LZRSB1210		 LZRDB1210	

12	

10

LZ

Product Selector Guide

High Capacity

Standard Models	 			
	

                  Electrical

	

	

	
	
	

	

	

	
Base Catalog Numbers	

	
	
	
	
	
	

LZ30 	
LZ35-12V 	
LZ65	
LZ65-12V	
LZ20N	
LZ25N-12V	

	

	

	

Output	
Volts	

Battery	
Type	

6	
12 	
6	
12	
6	
12	

Lead-Calcium 	
Lead-Calcium 	
Lead-Calcium 	
Lead-Calcium	
Nickel-Cadmium	
Nickel-Cadmium	

              Output Watts
1.5	
2	
3	
4	
Standard	
Hours 	 Hours 	 Hours	 Hours	
Lamp	
30 	
35 	
65 	
65 	
20	
25	

24 	
26 	
49 	
49 	
15	
19	

15 	
18 	
33 	
33	
10	
13	

12	
14	
26	
26	
8	
10	

5W Hal.	
5W Hal.	
5W Hal.	
5W Hal.	
5W Hal.	
5W Hal.	

Remote
Capability
Yes
Yes
Yes
Yes
Yes
Yes

Damp Location Models				
                    Electrical

		

	
	
	

	

	

	

Base Catalog Numbers	

	
Output	
Volts	

	
	
	
	
	
	

LZ25D 	
LZ30D-12V 	
LZ55D 	
LZ55D-12V	
LZ15ND 	
LZ20ND-12V 	

6	
12 	
6	
12 	
6	
12	

	

	

	
Battery	
Type	

Lead-Calcium 	
Lead-Calcium 	
Lead-Calcium 	
Lead-Calcium 	
Nickel-Cadmium 	
Nickel-Cadmium 	

               Output Watts
1.5	
2	
3	
4	
Standard	
Hours 	 Hours 	 Hours	 Hours	
Lamp	
25 	
30 	
55 	
55 	
15 	
20 	

19 	
24 	
42 	
42 	
11 	
15 	

13 	
15 	
28 	
28 	
8	
10 	

10	
12	
22	
22 	
6	
8	

5W Hal.	
5W Hal.	
5W Hal.	
5W Hal.	
5W Hal.	
5W Hal.	

Remote
Capability
Yes
Yes
Yes
Yes
Yes
Yes

Dimensions

5 1/8” (13 cm)

19

LM

High Capacity Emergency Lights
Features

•	 Easy to install
•	 Universal wall mounting pattern
•	 White, corrosion-resistant metal 	
housing and front-loading cover
•	 Maintenance-free battery
•	 6- & 12-volt models
•	 Damp location models available
•	 Glare-free lampheads
•	 Lampheads may be top or 	
side mounted
An
•	 Available with 3 or 4 lampheads
•	 Available without lampheads
Severe Conditions Product Line
•	 Matching remote fixtures
(1) Damp Location 	
•	 120/277VAC operation standard 	
Models Only
(1)
(220-240VAC, 60 Hz. optional)
(2)
Damp
Hot
Cold(2)
(2) NiCad Models Only
rdering
nformation

O

I

	 Example: LM130-3

14W to 130W

•	 Fully automatic, solid-state charger
•	 Low-voltage battery disconnect
•	 Transformer isolation protection
•	 Test switch and AC-On light
•	 Available with Spectron® selftesting/self-diagnostic electronics
	 with time-delay relay
(TDR) standard
•	 90 minute operation
•	 Temperature range: 	 20°C to 30°C
		
(68°F to 86°F)
	 NiCad models:	
20°C - 30°C
		
(68°F to 86°F)
	 Damp location models:	10°C to 40°C
		
(50°F to 104°F)
•	 UL 924 Listed

Ordering Information
See Product Selector Guide for available models

Options
Options
I			
-V 		
-3			
-4			
-0			
-A31	
	
-A32	
	
-24K		

(Add

suffix to model)

(Add

suffix to model)

Accessories
Accessories

(Order Separately)
(Order Separately)

Spectron self-testing/self-diagnostic electronics( 1)(5)	 40G		 Wire guard (Top mounted heads only)	
Voltmeter
SRHSW		 Single matching remote head - white *	
(1)(2)
Unit supplied with three lampheads
SRHDW		 Twin matching remote head - white *
(1)(2)
*	 Supplied with round mounting plate.  Specify voltage and wattage when
Unit supplied with four lampheads
	
ordering.  Example:  SRHDW1212.  See “Remote Heads and Fixtures”
	 section for available lamps.	
Unit supplied without lampheads (1)(2)(3)
Auxiliary 3-conductor AC line cord (120V)
Auxiliary 3-conductor AC line cord (277V)
220-240VAC, 60Hz. operation (4) 	

(1)	 Not available with LM2 model.
(2)	 Not available with LM16 model.
(3)	 NOTE: Spectron models with over 80 watts of capacity require a minimum
load of 35 watts for accurate lamp failure indications.
(4)	 Not available on units with capacities over 80 watts for 1.5 hours.

SRH Series Matching
Remote Lighting Heads

(5)	 Spectron not available with Nickel-Cadmium battery models.

Optional Lamps
To order two nonstandard lamps on the fixture, suffix
catalog number. See “Remote Heads and Fixtures” section for available lamps. Example: LM33-SRHSW0612.

Dimensions
F
E

C

Photometrics

B

Horizontal Isofootcandle Distribution
6 Volt, 7.2 Watt SBT Lamp 	

D

12 Volt, 7.2 Watt SBT Lamp

	 Enclosure	
	Style	A	

20

7

A

B	

C	

D	E	

3

1

1

F

3

	
1	
		

3 /8”	
5 /4”	 11 /2”	 13 /2”	 15 /4”	
25”
9.8 cm	 14.6 cm	 29.3 cm	 34.3 cm	 40.0 cm	 63.5 cm

	
2	
		

4 3/4”	
7 3/4”	 13 1/2”	 15 3/4”	
18”	
27 1/4”
12.1 cm	 19.7 cm	 34.3 cm	 40.0 cm	 45.7 cm	 69.2 cm

LM

Product Selector Guide
Standard Models (1)	
	
	
	
Catalog	
Numbers	

			

	
	

LM2	
LM16	
LM33	
LM40	
LM66	
LM80	
LM130	
LM40-12V	
LM66-12V	
LM80-12V	
LM130-12V	

	

	

Enclosure	
Style	

Output	
Volts	

1	
1	
1	
1	
2	
2	
2	
1	
2	
2	
2	

6	
6	
6	
6	
6	
6	
6	
12	
12	
12	
12	

                              Electrical
              Output Watts
1.5	
2	
3	
4	
Hours 	
Hours 	
Hours	
Hours	
	

14.4	
16	
33	
40	
66	
80	
130	
40	
66	
80	
130	

—	
—	
25	
31	
51	
62	
101	
31	
51	
62	
101	

—	
—	
17	
21	
35	
43	
70	
21	
35	
43	
70	

—	
—	
13	
16	
27	
33	
54	
16	
27	
33	
54	

Standard	 Remote
Lamp	
Capability
7.2W 	
7.2W 	
7.2W 	
7.2W 	
7.2W 	
7.2W 	
7.2W 	
7.2W 	
7.2W 	
7.2W 	
7.2W 	

No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Standard	
Lamp	

Remote
Capability

7.2W 	
7.2W 	
7.2W 	
7.2W 	
7.2W 	

No
Yes
Yes
Yes
Yes

Standard	
Lamp	

Remote
Capability

7.2W 	
7.2W 	
7.2W 	
7.2W 	
7.2W 	
7.2W 	
7.2W 	
7.2W 	
7.2W 	

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Standard	
Lamp	

Remote
Capability

12W	
12W	
12W 	

No
Yes
Yes

(1) Meets New York City Requirements

Nickel-Cadmium Models (1)			
		
	
		
Catalog	
Numbers	

	

LM15N	 	
LM30N		
LM50N	 	
LM50N-12V	
LM100N-12V	

	

	

Enclosure	
Style	

Output	
Volts	

1	
1	
1	
1	
1	

6	
6	
6	
12	
12	

                              Electrical
              	             Output Watts
1.5	
2	
3	
4	
Hours 	
Hours 	
Hours	
Hours	
14.4	
30	
50	
50	
100	

--	
25	
42	
42	
85	

--	
17	
29	
29	
59	

--	
13	
22	
22	
46	

(1) Meets New York City Requirements

Damp Location Models (1)	 			
		
	
	
Catalog	
Numbers	

	

LM28D	
LM34D	
LM56D	
LM68D	
LM112D	
LM34D-12V	
LM56D-12V	
LM68D-12V	
LM112D-12V	

	

	

Enclosure	
Style	

Output	
Volts	

1	
1	
2	
2	
2	
1	
2	
2	
2	

6	
6	
6	
6	
6	
12	
12	
12	
12	

                             Electrical
              Output Watts
1.5	
2	
3	
4	
Hours 	
Hours 	
Hours	
Hours	
	

28	
34	
56	
68	
112	
34	
56	
68	
112	

21	
26	
43	
53	
87	
26	
43	
53	
87	

15	
18	
30	
36	
60	
18	
30	
36	
60	

11	
14	
23	
28	
47	
14	
23	
28	
47	

(1) Meets New York City Requirements

All Metal City Of Chicago Models (2)			
	 	
	
		
Catalog	
Numbers	
LM24CH		
LM36CH		
LM36CH-12V	

	

	
Enclosure	
Style	

	
Output	
Volts	

1	
1	
1	

6	
6	
12	

                             Electrical
              	             Output Watts
1.5	
2	
3	
4	
Hours 	
Hours 	
Hours	
Hours	
24	
36	
36	

--	
26	
26	

--	
--	
--	

-- 	
-- 	
--	

(2) 2000 Chicago Building Code compliant

21

EZ-2R

Recessed Emergency Lights
Features
•	 Easy installation in wall or
ceiling
•	 Compact, low-profile design
•	 All metal recessed housing
•	 Flame-rated, thermoplastic
lamp housing and
mounting plate
•	 Maintenance-free battery
•	 Glare-free lampheads
•	 120/277VAC operation standard
•	 Fully automatic, solid-state
charger

10.8W, 14.4W

•	 Low-voltage battery disconnect
•	 Transformer isolation protection
•	 Test switch and AC-On light
•	 Available with Spectron®
self-testing/self-diagnostic
electronics with time-delay relay
(TDR) standard
•	 90 minute operation
•	 Temperature range: 	20°C to 30°C
		
(68°F to 86°F)
•	 UL 924 Listed

Ordering Information
	
	

Standard Model	
EZ-2R	

Spectron Self-Testing Model
EZ-2RI

A
(Orderto
 Separately
Occessories
ptions (Add suffix
model) )

Wall mounted EZ-2R unit

Accessories

(Order Separately)

F-CBM		 Troffer mounting kit (suspended ceilings)
WGEL		 Wire guard

EZ-2R suspended ceiling installation
using F-CBM accessory kit

Product Selector Guide

			

	

Electrical

  	
	
Base	
	 Catalog	
	 Number	
	

EZ-2R	

	
Output	
Volts	

	                   Output Watts
1.5	
2	
3	
Hours 	
Hours 	
Hours	

6	

10.8	

—	

4	
Hours	

Standard	
Lamp	

Remote
Capability

—	

5.4W 	

No

7.2W 	

No

—	

14.4	
—	
—	
—	
	
EZ-2RI*	
6	
* Includes Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard

Dimensions
Photometrics

E
D

G
F

Horizontal Isofootcandle Distribution
6 Volt, 5.4 Watt SBT Lamp	

A

5 3/4”
(14.6 cm)

B

11”
(27.9 cm)

C

3 7/8”
(9.8 cm)

D

7 3/4”
(19.7 cm)

E

9 1/8”
(23.2 cm)

F

5”
(12.7 cm)

G	

6 1/8”
(15.6 cm)

C

6 Volt, 7.2 Watt SBT Lamp

A

B

Photometrics measured by independent testing laboratory

22

Recessed T-Grid Emergency Lights
Features
•	 Easy to install T-Grid lay-in
design
•	 Maintenance-free battery
•	 6 and 12 volt models
•	 Heavy 20 gauge steel housing 	
•	 Standard white finish
•	 Standard with two glare-free
lampheads
•	 Dual voltage – 120V/277VAC
•	 Fully automatic, solid-state
charger
•	 Thermally compensated charger
•	 Regulated charge voltage

T-Grid

15W to 50W

•	 Automatic low voltage disconnect
•	 Reverse polarity protection
•	 Filtered charger output
•	 Short circuit protection
•	 AC lockout
•	 Test switch and AC-On light
•	 Available with Spectron®
self-testing/self-diagnostic
electronics with time-delay relay
(TDR) standard
•	 Temperature range: 	20°C to 30°C
		
(68°F to 86°F)
•	 UL 924 Listed

Ordering Information
Standard Models	
NiCad Battery Models	

Options
I	 	
-V	 	
-3	 	
-0	 	

(Add

TG15	
TG15N	

TG30 	
TG50-12V
TG30N 	 TG50N-12V

Accessories

suffix to model)

(Order Separately)

SRHSW		 Matching remote head - single *	
SRHDW		 Matching remote head - twin *

(1)

Spectron self-testing electronics
Voltmeter
Unit supplied with three lighting heads (2)
Unit supplied with no lighting heads

*	Supplied with round mounting plate.  Specify voltage and wattage
	 when ordering.
	 Example:  SRHSW1212.  See “Remote Heads and Fixtures” section for
	 available lamps.	

(1)	 Spectron not available with NiCad battery models.
(2)	 Not available on TG15 and TG15N models.

SRH Series
Matching Remote
Lighting Heads

Optional Lamps
To order two nonstandard lamps on the fixture, suffix
catalog number. See “Remote Heads and Fixtures” section for available lamps. Example: TG30-SRHSW0612.

Product Selector Guide
	

	

Electrical

	
 NiCad	
        Output Watts       	
	Standard	 Battery	 Output	 1.5 	
2	
3	
4	
	 Models	 Models	 Volts	 Hours	 Hours	Hours	 Hours	
	
	
TG15	
TG15N	
6	
15	
11	
8	
6
								
	
	 TG30	
TG30N	
6	
30	
22	
15	
12
								
	
	 TG50-12V	 TG50N-12V	
12	
50	
38	
25	
20
								

      AC Input*	
	
	
Volts	
Amps	
Watts	
	

120	
277	
120	
277	
120	
277	

.064 (.070)	
.029 (.032)	
.064 (.114)	
.029 (.051)	
.120 (.250)	
.051 (.108)	

7.0 (7.6)	
7.4 (8.0)	
7.0 (12.3)	
7.4 (12.7)	
12.6 (27.0)	
12.9 (26.9)	

Standard	 Remote
Lamp	 Capability
7.2W	

No

7.2W	

Yes

7.2W	

Yes

* AC Input figures in parenthesis are for NiCad battery models.

Photometrics

Dimensions
233/4”

(9.5 cm)

3 3/4”

Horizontal Isofootcandle Distribution
6 Volt, 7.2 Watt SBT Lamp

12 Volt, 7.2 Watt SBT Lamp

(60.3 cm)

7 1/4”
(18.4 cm)

51/4”
(13.3 cm)

23

EXT

Recessed Gimbal Emergency Light
Features
•	 Easy recessed installation in 	
suspended ceilings
•	 Built-in hanger bar
•	 Compact, low-profile design
•	 All metal housing and
gimbal assembly
•	 Ceiling white trim ring
•	 Lamp adjusts in two planes to 26˚
•	 High-output, 8 watt halogen
lamphead
•	 Maintenance-free battery

8W

•	 120/277VAC operation standard
•	 Fully automatic, solid-state
charger
•	 Low-voltage battery disconnect
•	 Transformer isolation protection
•	 Test switch and AC-On light
•	 90 minute operation
•	 Temperature range: 	20°C to 30°C
		
(68°F to 86°F)
•	 UL 924 Listed

Ordering Information
EXT-122-EM-K

Aptions
ccessories
(Order
 Separately
O
(Add suffix
to
model) )

Accessories

(Order Separately)

WGLX		 Wire guard

EXT-122-EM-K unit shown installed
using built-in hanger bars

Product Selector Guide

			

	

Electrical

  	
	
Base	
	 Catalog	
	 Numbers	

	

	

	

Output	
Volts	

	EXT-122-EM-K	

6	

              Output Watts
1.5	
2	
3	
Hours 	
Hours 	
Hours	
8	

—	

4	
Hours	

Standard	
Lamp	

Remote
Capability

—	

8W Hal.	

No

—	

Dimensions
6 1/8” (16.5 cm) Diameter

1
24 14” (
/2” 35.5
(62

7 1/2”

.2

(19.0 cm)

Photometrics
Horizontal Isofootcandle Distribution
(17

(m
(m in.)
ax
.)

7”

.7

6 Volt, 8 Watt Halogen SBT Lamp

cm
)
cm
)

cm

)

1 /2”
)
10 .6 cm

8 1/2”

(21.6 cm)

24

(26

Emergency Lighting Square Units
Features

Lite2

10W to 30W

•	 120/277VAC operation standard
•	 Fully automatic, solid-state charger
•	 Low-voltage battery disconnect
•	 Transformer isolation protection
•	 Test switch and AC-On light
•	 Available with Spectron® self-testing/
self-diagnostic electronics with timedelay relay (TDR) standard
•	 90 minute operation
•	 Temperature range: 	20°C to 30°C
		
(68°F to 86°F)
•	 UL 924 Listed

•	 Easy to install
•	 Matte-white frame and satinblack housing
•	 Available in single and twin
lamp models
•	 Maintenance-free battery
•	 Prismatic lens for uniform 	
illumination
•	 Polished alzak reflector
•	 Remote capability (ERS models
only)
•	 Matching remote fixtures

Ordering Information
			

Standard Models	

	

Spectron Self-Testing Models

	

EDS 	

	
	

ERS 	 Single lamp unit	 	
ERS-2-2	 Twin lamp unit	
ERS-3 	 Single lamp unit 				
ptions (Add suffix to model)

Single lamp unit	 	

O
Options

(Add

EDS-2	

Twin lamp unit	

ESS-I 	 Single lamp unit	 	
ERS-I 	 Single lamp unit	 	
ERS-3I 	Single lamp unit

Accessories
Accessories

suffix to model)

Voltmeter *
Fully recessed option

-V		
-FRM	

ESS-I-2	 Twin lamp unit
ERS-2I-2	 Twin lamp unit

F-SRM	 			
WG-MLT				
RERS-1-0609		
RERS-2-0607		

*  Not available with fully recessed models.

(Order Separately)
(Order Separately)

Semi-recessed mounting kit
Wire guard
Matching remote fixture - single lamp
Matching remote fixture - twin lamps

Product Selector Guide

			

	

  	

Electrical

	
	 	
	 Catalog	
	 Numbers	

	

              		
    Output Watts
Output	
1.5	
2	
3	
Volts	
Hours 	 Hours 	 Hours	

4	
Hours	

No.	
Lamps	

Standard	
Lamps	

Remote
Capability

EDS, ESS-I*	

6	

10	

—	

—	

—	

1	

9W	

No

ERS, ERS-I*	

6	

20	

10	

—	

—	

1	

9W	

Yes

	ERS-3, ERS-3I*	

6	

30	

22	

15	

—	

1	

9W	

Yes

	EDS-2, ESS-I-2*	

6	

14.4	

—	

—	

—	

2	

7.2W 	

No

	ERS-2-2, ERS-2I-2*	

6	

30	

22	

15	

—	

2	

7.2W 	

Yes

* Includes Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard

Dimensions
(Fully-Recessed)
4”

(10.1 cm)

Semi-recessed model

11 9/16” sq.

(29.4 cm)

(Semi-Recessed)

(Surface Mounted)
4”

2 1/4”

(10.1 cm)

Fully-recessed model

(5.7 cm)

9” sq.

(22.9 cm)

9” sq.

(22.9 cm)

25

Delite

Emergency Lighting Cylinder Units
Features

12W, 31W

•	 Low-voltage battery disconnect
•	 Transformer isolation protection
•	 Test switch and AC-On light
•	 90 minute operation
•	 Temperature range: 	20°C to 30°C
		
(68°F to 86°F)
•	 UL 924 Listed

•	 Easy to install
•	 Attractive matte-white cylinders
on contrasting black swivel
•	 Brushed aluminum base plate
•	 Multidirectional swivel lighting 	
heads
•	 Maintenance-free battery
•	 Matching remote fixture
•	 120/277VAC operation standard
•	 Fully automatic solid-state
charger

Ordering Information
ESC2-0

Options

(Add

Accessories

suffix to model)

(Order Separately)

Ceiling recess mounting kit
Wire guard

F-TMK	 		
41G			

Product Selector Guide
	

  	
	 Base	
	 Catalog	
	 Numbers	

	
Output	
Volts	

	 ESC2-0	

6	

	

Electrical
Output Watts
3	
4	
Hours	
Hours	

              		
1.5	
2	
Hours 	
Hours 	
12	

—	

—	

No.	
Cyls.	

Standard	
Lamp(s)	

Remote
Capability

2	

6W Halogen 	

No

—	

Dimensions
C
F
A
B
D

Photometrics
Horizontal Isofootcandle Distribution
6 Volt, 6 Watt Halogen SBT Lamp

10

10

Feet
Left

Feet
Left
LAMP
AXIS

0

IFC

0.5

0.3

26

IFC

Feet
Right

Feet
Right

10

LAMP
AXIS

0

0.1

0.2

0

10

20

30

40

50

Feet From Lamp (measured on axis)

60

E

Vertical Distribution

Horizontal Distribution

70

10

Unit Model	
  Number	
0.5

ESC2-0	

0.3

0.2

10”	

	
0

10

20

	
A	

0.1

        Dimensions
B	
C	
D	
4 3/4”	

10 1/2”	

8 1/2”	

E	

F

5”	

22”

25.4 cm	 12.0 cm	 26.7 cm	 21.6 cm	 12.7 cm	 55.9 cm
30

40

50

60
70
Dotted lines show heads
in maximum
horizontal position.

Feet From Lamp (measured on axis)

Harsh Environment Emergency Lights
Features
•	 Gasketed construction

•	 Low-voltage battery disconnect

•	 Corrosion resistant hardware

•	 Transformer isolation protection

•	 Charcoal grey thermoplastic case

•	 Test switch and AC-On light

•	 Available in 6- or 12-volt versions
•	 Maintenance-free battery

•	 Available with Spectron®
self-testing/self-diagnostic
electronics with time-delay relay
(TDR) standard

•	 Capacities up to 100W

•	 90 minute operation

•	 Matching remote fixture

•	 Temperature range: 	10°C to 40°C
		
(50°F to 104°F)

•	 Fully adjustable lampheads

•	 120/277VAC operation standard
•	 Fully automatic, solid-state
charger

•	 UL 924 Listed

An

•	 UL 924 Damp Location Listed

Severe Conditions Product Line

Ordering Information
N4X2		

N4X4	

Options

N4X7	

(Add

N4X7-12V	 	

N4X14	

N4X14-12V

(Order Separately)

A

(a)	 Supplied with mounting plate.  
	 Specify voltage and wattage when ordering.  
	 Example:  GNXSB0618.  
	 See “Remote Heads and Fixtures” section for
	 available lamps.

(1)	 Not available on N4X2 model.

Lamps With Optional Shatter Containment Feature
Protective lamp cover safely contains glass lamp fragments in the
event of accidental breakage in sensitive areas such as food preparation or hospitals. To order N4X unit with shatter containment option,
suffix the catalog number. See “Remote Heads and Fixtures” section
for available lamps (1). Example: N4X4-GNXSB0608-L.

Optional Lamps
To order two nonstandard lamps on the fixture,
suffix catalog number. See “Remote Heads and
Fixtures” section for available lamps. Example:
N4X4-GNXSB0612.

(1)	 Excludes 6V, 7.2W and 12V, 9W lamps.

Product Selector Guide
  	

Damp(1)

40G		 Wire guard
GNXSB		 Matching remote head - single (a)
(a)
ccessories
(O
rder
 Separately
)
GNXDB		
Matching remote
head
- twin
	

O

      Electrical

	 Base	
	 Catalog	
	 Numbers	
	 N4X2	
	 N4X4	
	 N4X7	
	 N4X7-12V	
	 N4X14	
	N4X14-12V	

	
Output	
Volts	

	

	
1.5	
Hours 	

6	
6	
6	
12	
6	
12	

15	
31	
50	
50	
100	
100	

          Output Watts
2	
3	
Hours 	
Hours	
—	
22	
36	
36	
79	
79	

—	
15	
29	
29	
61	
61	

4	
Hours	

Standard	
Lamps	

Remote
Capability

—	
—	
22	
22	
44	
44	

7.2W 	
7.2W 	
7.2W 	
9W 	
7.2W	
9W 	

No
Yes
Yes
Yes
Yes
Yes

Dimensions
5/8”

Diam.

Photometrics
Horizontal Isofootcandle Distribution
6 Volt, 7.2 Watt SBT Lamp

12 3/4” (32.4 cm)
13 5/8” (34.6 cm)
16 1/4” (41.3 cm)

	

Corrosive

Accessories

suffix to model)

I		
Spectron self-testing/self-diagnostic electronics	
-0		
Unit supplied without lighting heads (1)
(1)
(Add
to head
model
)
-1		 ptions
Unit supplied
withsuffix
one lighting
-A31	
Auxiliary 3-conductor AC line cord (120V)
-A32	
Auxiliary 3-conductor AC line cord (277V)

			

N4X

15W to 100W

6”
10 1/4”

12 Volt, 9 Watt SBT Lamp

4 7/8”
11” Max.

27

AS

Industrial Emergency Lights
Features
•	 Easy to install
•	 NEMA 1 steel cabinet with dark
brown enamel finish
•	 1/2” and 3/4” wiring KOs
provided
•	 Wet-cell and maintenance-free 	
battery models
•	 6-, 12- and 24-volt models
•	 12- and 24-volt models allow 	
longer wiring runs
•	 Glare-free lampheads
•	 Available with third lamphead
•	 Available without lampheads
•	 Matching remote fixtures

75W to 360W

•	 120/277VAC operation standard
•	 Fully automatic, solid-state charger
•	 Low-voltage battery disconnect
•	 Transformer isolation protection
•	 Test switch and AC-On light
•	 Available with Spectron®
self-testing/self-diagnostic
electronics with time-delay relay
(TDR) standard
•	 90 minute operation
•	 Temperature range: 	20°C to 30°C
		
(68°F to 86°F)
•	 UL 924 Listed

Ordering Information
See Product Selector Guide for available models
SRH Series
Matching Remote
Lighting Head

Options
I			
-V 			
-C 			
-0			
-1	 		
-2	 		
-3	 		
-A31		
-A32	 	

(Add

Accessories

suffix to model)

Spectron self-testing/self-diagnostic electronics
Voltmeter
Ammeter (1)
Unit supplied without lampheads
Unit supplied with one lamphead
Unit supplied with two lampheads (2)
Unit supplied with three lampheads
Auxiliary 3-conductor AC line cord (120V)
Auxiliary 3-conductor AC line cord (277V)

(1)	 Not available with all models.  Consult factory.
(2)	 Available for use with 12EDC
	 and 12EDN models only.  All other
	 models are supplied standard with
	 two lampheads.

Photometrics

(1)

WB-6		
6000		
			
L-6		
L-12-S		
40G		
41G		
SRHSB		
SRHDB		

(Order Separately)

Wall mounting hanger bracket (all models)
Heavy-duty mounting shelf (Enclosure 1 	
models)
Mounting shelf (Enclosure 1 models)
Mounting shelf (Enclosure 2 models)
Wire guard (Enclosure 1 models)
Wire guard (Enclosure 2 models)
Matching remote lighting head - single *	
Matching remote lighting head - twin *

*	 Supplied with round mounting plate.  Specify voltage and wattage
when ordering.  Example:  SRHSB0612.  See “Remote Heads and
Fixtures” section for available lamps.	

Optional Lamps
To order two nonstandard lamps on the fixture, suffix
catalog number. See “Remote Heads and Fixtures” section for available lamps. Example: AS130-SRHSB0612.

Dimensions

Horizontal Isofootcandle Distribution
6 Volt, 7.2 Watt SBT Lamp	

12 Volt, 7.2 Watt SBT Lamp

D
C

6 Volt, 25 Watt SB Lamp	

24Volt, 7.2Watt SB Lamp

B

A

	Enclosure	 Enclosure

	

Style	

Ga.	

A	

B	

14”	

8”	

111/2”	 18 3/4”

8”	

111/2”	 18 3/4”

				
1	
20 Ga. (.036”)	 35.5 cm	
16”	
				
2	
20 Ga. (.036”)	 40.6
cm	

28

C	

D

20.3 cm	 29.2 cm	 47.6 cm
20.3 cm	 29.2 cm	 47.6 cm

AS

Product Selector Guide
Maintenance-Free Battery Models		
	

		

  	
	
Base	
	 Catalog	
	 Numbers	

Electrical
	

	
Enclosure	
Style	

	
Output	
Volts	

	

AS80	 	

1	

6	

80	

62	

AS130		

1	

6	

130	

AS180-12V	

1	

12	

AS270-12V	

1	

AS360-12V	

1.5	
Hours 	

           Output Watts
2	
3	
Hours 	
Hours	

4	
Hours	

Standard	
Lamp	

Remote
Capability

43	

33	

7.2W 	

Yes

101	

70	

54	

7.2W 	

Yes

180	

144	

112	

77	

7.2W 	

Yes

12	

270	

227	

168	

116	

7.2W	

Yes

1	

12	

360	

288	

230	

172	

7.2W	

Yes

AS180-24V	

1	

24	

180	

144	

112	

77	

9.0W 	

Yes

AS270-24V	

1	

24	

270	

227	

168	

116	

9.0W 	

Yes

AS360-24V	

1	

24	

360	

288	

230	

172	

9.0W	

Yes

4	
Hours	

Standard	
Lamp	

Remote
Capability

NOTE: 	 Batteries for all Maintenance-Free models are shipped with the units.

Wet-Cell Lead-Calcium Battery Models		
	

		

  	
	
Base	
	 Catalog	
	 Numbers	

Electrical
	

	
Enclosure	
Style	

	
Output	
Volts	

	

ALC-X-30	

1	

6	

78	

57	

42	

28	

25W 	

Yes

ALC-X-60	

1	

6	

144	

108	

81	

54	

25W 	

Yes

ALC-X-100	

1	

6	

162	

121	

91	

61	

25W 	

Yes

12EDC-X-36S	

2	

12	

200	

165	

125	

86	

(*)	

Yes

12EDC-X-60S	

2	

12	

240	

192	

153	

115	

(*)	

Yes

12EDC-X-120S	

2	

12	

350	

280	

224	

168	

(*)	

Yes

4	
Hours	

Standard	
Lamp	

Remote
Capability

1.5	
Hours 	

           Output Watts
2	
3	
Hours 	
Hours	

(*) These models supplied standard without lampheads

NOTE: 	 Batteries for all Wet-Cell Lead-Calcium models are shipped separately.

Wet-Cell Nickel-Cadmium Battery Models		
	

  	
	
Base	
	 Catalog	
	 Numbers	

		
Electrical

	

	
Enclosure	
Style	

	
Output	
Volts	

	

AS75		

1	

6	

75	

57	

42	

28	

25W 	

Yes

AS145		

1	

6	

110	

85	

59	

46	

25W 	

Yes

AS210		

1	

6	

145	

112	

84	

54	

25W 	

Yes

12EDN-10S	

2	

12	

48	

38	

25	

20	

(*)	

Yes

12EDN-18S	

2	

12	

100	

76	

54	

44	

(*)	

Yes

12EDN-30S	

2	

12	

150	

115	

86	

57	

(*)	

Yes

1.5	
Hours 	

           Output Watts
2	
3	
Hours 	
Hours	

(*) 	These models supplied standard without lampheads

NOTE: 	 Batteries for all Wet-Cell Nickel-Cadmium models are shipped separately.

29

IPS

Wet Location Emergency Lights
Features
•	 Suitable for wet or damp
applications
•	 Designed for Class I, Div 2 locations
•	 Compact, factory assembled system
•	 Sealed and gasketed NEMA 3R
construction
•	 Corrosion resistant hardware
•	 Black thermoplastic case with
battery vent
•	 Available in 6- or 12-volt versions
•	 Fully adjustable 8 watt halogen
sealed beam lampheads
•	 Maintenance-free battery
•	 Matching remote fixtures

An
Severe Conditions Product Line

36W, 72W

•	 120/220/240/277VAC operation
standard
•	 Fully automatic, solid-state charger
•	 Automatic 15-minute retransfer
delay
•	 Low-voltage battery disconnect
•	 Transformer isolation protection
•	 Test switch and AC-On light
•	 T-6 100°C (212°F) lamphead rating
•	 120 minute operation
•	 Temperature range: 	0°C to 40°C
		
(32°F to 104°F)
•	 UL Listed to Standard 924 and 		
Standard 844 (Hazardous Locations)

Ordering
Information
844
NEMA 3R Enclosures (NEMA Standards 250)
Hazardous

Damp

Corrosive

Wet

Enclosures are intended for outdoor use primarily to provide a degree of
protection against falling rain and sleet, undamaged by the formation of
ice on the enclosure.

Ordering Information
Options
(Add	 suffixC1D2-12V36	
to model) C1D2-12V72	 Accessories
C1D2-6V36		
C1D2-6V72

(Order Separately)

		

Options
-0		
-1		
-12	

(Add

suffix to model)

Unit supplied without lampheads
Unit supplied with one lamphead
Unit supplied with 12 watt halogen lamps

Product Selector Guide

			

	

  	

	 Base	
	 Catalog	
	 Numbers	
	C1D2-6V36	
	C1D2-6V72	
	C1D2-12V36	
	C1D2-12V72	

            Electrical
	

	

	

Output	
Volts	

2	
Hours 	

6	
6	
12	
12	

36	
72	
36	
72	

            Output Watts
3	
Hours 	
24	
50	
24	
50	

Photometrics
Horizontal Isofootcandle Dist.
6 Volt, 8 Watt Halogen SB Lamp

Photometrics measured by independent
testing laboratory

30

12 Volt, 8 Watt Halogen SB Lamp

4	
Hours	

Standard	
Lamps	

Remote
Capability

19	
39	
19	
39	

8W Hal. 	
8W Hal. 	
8W Hal. 	
8W Hal. 	

Yes
Yes
Yes
Yes

Accessories

IPS

(Order Separately)
Remote Lighting Heads

	 	 Lamp	 	
	 Volts	 	Watts	

Matching single and twin head
remote lighting fixtures

	
Single-Head Model Numbers	
Hub Left Side	
Hub Right Side	
Hub Both Sides	

	

6		

8	

C1D2R-6V8W	

C1D2R-6V8WR	

C1D2R-6V8WF

	

6		

12	

C1D2R-6V12W	

C1D2R-6V12WR	

C1D2R-6V12WF

	

12		

8	

C1D2R-12V8W	

C1D2R-12V8WR	

C1D2R-12V8WF

	

12		

12	

C1D2R-12V12W	

C1D2R-12V12WR	

C1D2R-12V12WF

	 	 Lamps	 	
	 Volts	 	Watts	

	
Twin-Head Model Numbers	
Hub Left Side	
Hub Right Side	
Hub Both Sides	

	

6		

8	

C1D2TR-6V8W	

C1D2TR-6V8WR	

C1D2TR-6V8WF

	

6		

12	

C1D2TR-6V12W	

C1D2TR-6V12WR	

C1D2TR-6V12WF

	

12		

8	

C1D2TR-12V8W	

C1D2TR-12V8WR	

C1D2TR-12V8WF

	

12		

12	

C1D2TR-12V12W	

C1D2TR-12V12WR	

C1D2TR-12V12WF

*  PAR 36 Halogen sealed beam lamps.

Dimensions
11/2”
(3.8 cm)
1.9 cm

17”
(43.1 cm)

12 1/2”
(31.7 cm)
11 1/4”
(28.6 cm)

12”
(30.5 cm)

6 3/4”
(17.1 cm)

13 1/4”
(33.7 cm)

95/8”

9 5/8”
(24.4 cm)

Mounting holes

41/4”

7

227//88””
(7.3 cm)

7711//22”
(1981cm)
/8”
8 1/8”
(20.6 cm)

3

/4” Hub
1.9 cm

4 1/4”
(10.8 cm)

1111//44””
(3.25 cm)
4 /8”

5

4 /8”
(14.3 cm)

Mounting
holes

7

2 7/8”
2 /8”
(7.3 cm)

3
/4” Hub
1.9 cm

12”
12”
(30.5
cm)
125/8”
12 5/8”
(32.1 cm)

31

XPB

Explosion-Proof Emergency Lights
Features
•	 Suitable for Class I, Div. I & II
applications
•	 High-strength, copper-free
aluminum housing
•	 Quick access thread-on cover
•	 Test switch included
•	 AC-On indicator light
•	 Maintenance-free battery
•	 6- and 12-volt models

An
Corrosive

Severe Conditions Product Line

75W

•	 Capacity for remote fixtures
•	 120/277VAC operation standard
•	 Fully automatic, solid-state charger
•	 Low-voltage battery disconnect
•	 Transformer isolation protection
•	 Optional fixtures available for
a wide range of hazardous
environments
•	 90 minute operation
•	 Temperature range: 	20°C to 30°C
		
(68°F to 86°F)
•	 UL Listed to Standard 924
and Standard 844 (Hazardous
Locations)

Ordering Information
Ordering Information

(Class I, Divisions I & II, Groups C through G)

Explosion-Proof

XPB-75P		 12XPB-75P

Options
-TDR 		

(Add

Accessories

suffix to model)

(Order Separately)

15-minute retransfer delay (120VAC only)

Product Selector Guide

			
	
	

Electrical

	
Base			
Output Watts
Output	
1.5	2	3	4	
	 Catalog	
	 Numbers	
Volts	
Hours 	
Hours 	
Hours	
Hours	
	

XPB-75P	

	 12XPB-75P	

Standard	
Lamp	

Remote
Capability

6	

75	

57	

42	

28	

(*)	

Yes

12	

75	

57	

42	

28	

(*)	

Yes

(*) Unit is supplied without lighting fixtures.  Unit must operate at least one lighting fixture (unit mounted or remote)
to meet UL Standard 924 requirements.  See following page for explosion-proof lighting fixtures and accessories.

Dimensions
10 3/4”

12”

(27.3 cm)

6 3/16”

(30.5 cm)

(15.7 cm)

XPB-75P shown with EX-1CD
unit-mounted lighting fixtures
14 1/2”
(36.8 cm)

Depth = 8” (20.3 cm)

32

3”
(7.6 cm)

Depth = 5 9/16” (14.1 cm)

Explosion-Proof Fixtures (1)
Fixtures for direct mounting to XPB Series Unit
EX-1CD
All fittings required for unit mounting supplied standard. Up to three
fixtures may be connected (unit mounted and/or remote).

Catalog	
Number	
EX-1CD618	
EX-1CD628	
EX-1CD

Lamp	
Lamp	
Voltage	 Wattage	
6	
6	

18	
28	

Catalog	
Number	
EX-1CD1218	
EX-1CD1228	

Lamp	
Lamp
Voltage	 Wattage
12	
12	

18
28

Fixtures for remote mounting
REX1CDP*
Fixture for pendant mounting; one 1/2” hub, rigid or flexible mounting.

Catalog	
Number	
REX1CDP

Lamp	
Lamp	
Voltage	 Wattage	

Catalog	
Number	

Lamp	
Lamp
Voltage	 Wattage

REX1CDP618	

6	

18	

REX1CDP1218	

12	

18

REX1CDP628	

6	

28	

REX1CDP1228	

12	

28

REX1CDC*
Fixture for ceiling mounting; four 1/2” hubs, three close-up plugs.

Catalog	
Number	
REX1CDC

Lamp	
Lamp	
Voltage	 Wattage	

Catalog	
Number	

Lamp	
Lamp
Voltage	 Wattage

REX1CDC618	

6	

18	

REX1CDC1218	

12	

18

REX1CDC628	

6	

28	

REX1CDC1228	

12	

28

REX1CDW*
Fixture for wall mounting; four 1/2” hubs, three close-up plugs.

Catalog	
Number	
REX1CDW

Lamp	
Lamp	
Voltage	 Wattage	

Catalog	
Number	

Lamp	
Lamp
Voltage	 Wattage

REX1CDW618	

6	

18	

REX1CDW1218	

12	

18

REX1CDW628	

6	

28	

REX1CDW1228	

12	

28

REX1CDA*
Fixture for angled (15°) wall mounting; two 1/2” hubs, one close-up plug.

Catalog	
Number	
REX1CDA

Fixture Accessories

XWG
XWG	
EX100CD	
	
REX-SDR	
REX-AR	

REX1CDA618	
REX1CDA628	

Lamp	
Lamp	
Voltage	 Wattage	
6	
6	

18	
28	

Catalog	

Number	
REX1CDA1218	
REX1CDA1228	

Lamp	

Lamp

Voltage	 Wattage
12	
18
12	
28

*  Fixtures shown with optional “XWG” globe guards.
(1)	 When connected to XPB emergency units, lighting fixtures will operate in the
“normally-off” mode.

EX100CD

REX-SDR

REX-AR

Aluminum (copper-free) globe guard. Protects fixture lens from accidental impact damage. Two-coat, baked
epoxy, medium-gray enamel finish.
Auxiliary housing with “EXIT” legend for “normally off” operation only. Housing constructed of 18-gauge
sheet metal; medium-gray enamel finish. Glass face with 6” high, 3/4” stroke red letters on white
background. (Lighting fixture not included).
Standard dome reflector. Steel, with white porcelain enamel finish.
Angled (30°) reflector. Steel, with white porcelain enamel finish.

33

Lampak

Fluorescent Power Packs
Features

UFO-3, 4, 5, 6
W

NE

An
Severe Conditions Product Line

Damp

• Battery case made of heavy 22gauge steel
•	 Reliable, high-frequency inverter
•	 Sealed nickel-cadmium battery
•	 Universal 120/277VAC operation
• 	Test switch and LED charge
	 indicator light supplied standard
• Provides 90 minutes of
	 emergency lighting
• Low power consumption
•	 Temperature range: 	0°C to 50°C 	
	
(32°F to 122°F)
• 	UL 924 Listed (Emergency Lighting)
• 	UL 924 Damp Location Listed

•	 Compatible with electronic,
standard magnetic, energy
	 saving, and dimming AC ballasts
• 	Compatible with most standard
T8, T10 or T12, energy-saving or
rapid start, (4-pin) long compact
fluorescent lamp
• Easy installation with versatile
mounting capability inside of
ballast channel, on top of or
remote from fixture
• 	Operates one or two lamps in
emergency mode
•	 Can be used with switched or
unswitched lighting fixtures

Ordering Information
Standard Models
UFO-3AW, UFO-4W, UFO-5W, UFO-5AW, UFO-6W
Self-Testing Spectron Model
UFO-6WI
ptions (Add suffix to model)

O

Accessories

(Order Separately)

F-WC		 Wire bundle cover (1)
SPRTS		 Remote test switch/charge indicator 		
ccessories (Order Separately)
			 module (2)

A

(1)	 Encloses exposed wiring harness when power pack is externally
mounted on the lighting fixture.  One required per fixture.

Extended Temperature Model*
UFO-6W-CLD

(2)	 Fits single-gang box.

* Extends temperature range to -20°C to 55°C  (-4°F to 131°F)

Product Selector Guide
Catalog	
Number	

Output	
Wattage	

Initial	
Lumens	

Electrical
Number
of Lamps	
Operated	

	 UFO-3AW	
	 UFO-4W	
	 UFO-5W	
	 UFO-5AW	
	 UFO-6W, UFO-6WI	
	 UFO-6W-CLD	

9.6	
14.4	
14.4	
14.4	
24.0	
24.0	

350-450	
500-600	
600-700	
600-700	
1100-1400	
Up to 1200	

1	
1	
1	
1 or 2	
1 or 2	
1 or 2	

	

	
	
	

Base	

	

	

Lamp	
Sizes	

Input
Wattage

2’-4’	
2’-4’	
2’-8’	
2’-8’	
2’-8’	
2’-8’	

3.5
3.5
3.5
3.5
4.0
4.0

Installation
Lampak UFO 3, 4, 5 and 6 emergency power
packs do not affect normal fixture operation and
may be used with either switched or unswitched
fixtures. UFO-3, 4, 5 and 6 packs may be installed
inside, on top of, or remote from the fixture. The
fluorescent pack may be remotely installed up to
half the distance from the lamp the AC
ballast manufacturer recommends, or up to 50
feet, whichever is less. UFO-3, 4, 5 and 6 packs are
not suitable for installation in heated air outlet
fixtures and wet or hazardous location fixtures.
Installation is not recommended with fixtures where
the ambient temperature may fall below 0°C (32°F ).

Dimensions
B
A
C

	 Model	

34

A	

B	

C

	 UFO-3AW, 4W, 5W, 5AW	

9 3/8” (23.8 cm)	 11/2” (3.8 cm) 	 2 3/8” (6.0 cm)

	 UFO-6W, -6WI & -6-CLD	

13 3/8” (33.9 cm)	 1 1/2” (3.8 cm) 	 2 3/8” (6.0 cm)

Lampak

High Lumen Fluorescent Power Packs
Features
• Standard and Spectron self-testing/
self-diagnostic models offered.
• Compatible with electronic,
standard magnetic, energy
	 saving, and dimming AC ballasts
• Compatible with most standard
2 - 8 foot, T8, T9, T10 or T12 and
rapid-start (4-pin) long compact
fluorescent lamps
• Easy installation on top of or
remote from fixture
• Operates one or two lamps
depending on fixture
• Can be used with switched or
unswitched lighting fixtures

UFO-7

• Battery case made of 22-gauge steel
• Reliable, high-frequency inverter
• Premium sealed nickel-cadmium
battery
• Universal 120/277VAC operation
• Test switch and LED charge indicator
light supplied standard
• 90 minutes emergency operation
• Low power consumption
• Temperature range: 	0°C to 40°C
		
(32°F to 104°F)
• UL 924 Listed (Emergency Lighting)
• UFO-7WI Model UL 924 Damp
Location Listed

W

NE

An
Severe Conditions Product Line

Ordering Information
UFO-7W (Standard Model)	
UFO-7WI (Self-Testing Model)

Options

(Add

Damp

* UFO-7WI Model Only

Accessories

(Order Separately)

F-WC		 Wire bundle cover (1)
SPRTS		 Remote test switch/charge indicator 		
ccessories
(Order Separately)
			
module (2)

A

suffix to model)

(1)	 Encloses exposed wiring harness when power pack is externally
mounted on the lighting fixture.  One required per fixture.
(2)	 Fits single-gang box.

Product Selector Guide
	
	
	
	

Catalog	
Number	

	
	

UFO-7W	
UFO-7WI	

Base	

Output	
Wattage	

	

Initial	
Lumens	

Electrical
Number
of Lamps	
Operated	

Lamp	
Sizes	

Input
Wattage

57.6	
57.6	

1450-3500	
1800-3500	

1 or 2	
1 or 2	

2’-8’	
2’-8’	

8.0
8.0

	

Table 1 (Models UFO-7W, UFO-7WI)*
	
	

Lamp	
Base Type	
Diameter		

Power	
(Length)	

No. of Lamps
Operated (Emerg.)

Single or	
Bipin	
4-Pin	
(2G11)	

17 - 40W (2’ to 4’)	
40 - 215W (5’ to 8’)	
18 - 39W	
40 - 55W	

1 or 2
1
1 or 2
1

4-Pin	
(G24q, GX24q)

18 - 42W	

1 or 2

	(1”, 11/8”,11/4”,11/2”)	
	 T8, T9, T10, T12	
	
Long	
	
Compact	
	
Compact	
		

* Partial listing of lamps operated

Table 2*
	
Lamp	
	
Type	
	 FO25, FBO24 T8	
	 FO32, FBO31 T8	
	
FO40 T8	
	
FO96 T8	
	 F40 T12, F40/U	
	 F40 T12ES (34W)	
	
F48 T12/HO	
	
F96 T12	
	
F96 T12/HO	
	 F96 T12/VHO	

Lumens
1 Lamp 	2 Lamps
2250	
2600
3000	
3000
2400	
-3000	
-3000	
3000
2700	
2700
3000	
-2800	
-2900	
-3300	
--

Table 2* (Continued)
	
Lamp	
	
Type	
	 PL-L 24W, F27/24BX	
	 Dulux L 27W
	 PL-L 36W, F39/36BX	
	 Dulux L 39W
	
PL-T 42W/4P	
	 PL-L 40W, F40/30BX	
	 F50BX, Dulux L 55W
	
F28 2D/4P	
	
F38 2D/4P	

Lumens
1 Lamp 	2 Lamps
1800	
2300
2900	

3500

3200	
1800	

3500
--

2050	
1450	

2800
2800

Installation
LAMPAK UFO-7W Series emergency power packs do not
affect normal fixture operation and may be used with
either switched or unswitched fixtures. UFO-7W Series
models may be installed on top of, or remote from the
fixture. The emergency ballast may be remotely installed
up to half the distance from the lamp the AC ballast
manufacturer recommends, or up to 50 feet, whichever
is less.
UFO-7W Series emergency power packs are not suitable
for installation in heated air outlet fixtures and wet or
hazardous location fixtures. Installation is not recommended with fixtures where the ambient temperature
may fall below 0°C (32°F ).

Dimensions
16.3”

1.7”

41.4cm

4.4cm

5.5”

13.8cm

* Partial listing of lamps operated.
Initial lumen output measured at 25°C
ambient temperature.

35

Lampak

Compact Fluorescent Power Packs
Features

UFO-12
W

NE

An
Severe Conditions Product Line

Damp

•	 Compatible with electronic,
	 standard magnetic, energy saving,
and dimming AC ballasts
•	 Compatible with most 13W to
42W rapid start, 4-pin compact
twin, quad or triple twin tube
fluorescent lamps
• 	Easy installation on top of or
remote from fixture
• 	Operates one or two lamps in
emergency mode
• Can be used with switched or
unswitched lighting fixtures
• Battery case made of heavy 22gauge steel

• Reliable, high-frequency
	 inverter
• Premium sealed nickel-cadmium
battery
• Universal 120/277VAC operation
• 	Test switch and LED charge
	 indicator light supplied standard
•	 90 minute operation
•	 Low power consumption
•	 Temperature range:	 0°C to 50°C 	
	
(32°F to 122°F)
• 	UL 924 Listed (Emergency Lighting)
• 	UL 924 Damp Location Listed

Ordering Information
UFO-12W

Accessories

Options

(Add

(Order Separately)

F-WC		 Wire bundle cover (1)
SPRTS		 Remote test switch/charge indicator 		
			 module (2)
ccessories
rder
eparately
)
(1)	 Encloses
exposed wiring harness(O
when
power S
pack
is externally

A

suffix to model)

mounted on the lighting fixture.  One required per fixture.
(2)	 Fits single-gang box.

Product Selector Guide
	

Electrical

	
Base	
	 Catalog	
	 Number	
		
	 UFO-12W	
		
		

	
Ballast	
Compat.	

	
Number
Initial	 of Lamps	
Lumens	 Operated	

Magnetic,	
See	
See	
Electronic,	
Table 1	
Table 1	
Energy Saving			
& Dimming			

Lamp	
Type	

13W through 42W quad and 		
triple tube lamps without 	
G24q-2, G24q-3	
integral starters (4-pin lamps) 	
GX24q-3, GX24q-2

Table 1*
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	

Lamp	
Type (4-Pin)	
PL-T 42W/4P, Dulux T/E 42W	
PL-T 32W/4P, Dulux T/E 32W	
PL-T 26W/4P, Dulux T/E 26W, F26TBX/4P	
PL-T 18W/4P, Dulux T/E 18W, F18TBX/4P	
PL-C 26W/4P, Dulux D/E 26W, F26DBX/4P	
PL-C 18W/4P, Dulux D/E 18W, F18DBX/4P	
PL-C 13W/4P, Dulux D/E 13W, F13DBX/4P	
PL-L 40W, Dulux L 40W, F40/30 BX/4P	
PL-L 36W, Dulux L 39W, F39/36 BX/4P	
PL-L 24W, Dulux L 27W, F27/24 BX/4P	
PL-L 18W, Dulux L 18W, F18 BX	
F3 82D/4P	
FO25, FBO24 T8	
FQL 28	
FO17, FBO16 T8	

Base	
Types	

Lumens
1 Lamp	2 Lamps
750	
-575	
750
450	
725
300	
525
600	
700
475	
575
350	
425
650	
-575	
750
475	
550
300	
400
525	
650
525	
700
600	
700
425	
500

Input
Wattage
3.5

Application
LAMPAK Series UFO-12W emergency power pack does
not affect normal fixture operation and may be used
with either a switched or unswitched fixture. The UFO12W may be installed on top of, or remote from the
fixture. The emergency ballast may be remotely installed
up to half the distance from the lamp the AC ballast
manufacturer recommends, or up to 50 feet, whichever
is less. UFO-12W emergency power packs are not suitable for installation in heated air outlet fixtures and wet
or hazardous location fixtures. Installation is not recommended with fixtures where the ambient temperature
may fall below 0°C (32°F ).

Dimensions

* Partial listing of lamps operated
Initial lumen output measured at 25°C ambient temperature.

1.5”

3.8cm

9.4”

23.8cm

2.4”

6.0cm

36

Lampak

Low-Profile Fluorescent Power Packs
Features
•	 Low profile design
•	 Compatible with electronic
(including those containing
end-of-life shutdown circuits),
standard magnetic, energy saving,
and dimming AC ballasts
•	 Compatible with most standard
and HO T5 miniature bipin, T8
bipin and rapid-start (4-pin)
long compact lamps
•	 Easy ballast channel installation
•	 Operates one lamp
•	 Can be used with switched or
unswitched lighting fixtures

UFO-LP

• Compact battery case
• Reliable, high-frequency inverter
• Premium sealed nickel-cadmium
battery
• Universal 120/277VAC operation
• 	Test switch and LED charge indicator
light supplied standard
• Provides 90 minutes of emergency
lighting
• Low power consumption
•	 Temperature range: 	0°C to 50°C 	
	
(32°F to 122°F)
• 	UL 924 Listed (Emergency Lighting)

W

NE

Ordering Information
UFO-LP1 (Standard Output Model)	
UFO-LP2 (High Output Model)

Options

(Add

Accessories

(Order Separately)

SPRTS		 Remote test switch/charge indicator 		
			 module (1)
(1)	 Fits
single-gang box.
ccessories
(Order Separately)

A

suffix to model)

Product Selector Guide
	
	
	
	
	
	

Electrical
Base	

Catalog	
Number	

	

Lumen	
Output	

Number
of Lamps	
Operated	

UFO-LP1	
UFO-LP2	

See Table 1	
See table 2	

1	
1	

	

Lamp Type	
Lumens
700
FP54, F54 T5/HO	
FP39, F39 T5/HO	
620
FP24, F24 T5/HO	
390
FP28, F28 T5	
700
FP21, F21 T5	
620
FP14, F14 T5	
430
F32 T8 (4’)	
635
F40 T8 (5’)	
570
F48 T8/HO (4’) (44W)	
470
PL-L 50W, F50BX/RS, Dulux L 55W	 510
PL-L 40W, F40/30BX, Dulux L 55W	 625
PL-L 36W, F39/36BX, Dulux L 55W	 610

T5 HO, T5, T8 HO, T8, 4-pin Compact	
T5 HO, T5, T8 HO, T8, 4-pin Compact	

Input
Wattage
3.2
3.0

Table 2 (UFO-LP2)*

Table 1 (UFO-LP1)*
	
	
	
	
	
	
	
	
	
	
	
	

Lamp	
Types	

	

	
	
	
	
	
	
	
	
	
	
	
	
	
* Partial listing of lamps operated.
Initial lumen output measured at 25°C 	
ambient temperature.
	

Lamp Type	
Lumens
1250
FP54, F54 T5/HO	
FP39, F39 T5/HO	
1125
FP24, F24 T5/HO	
725
FP28, F28 T5	
1325
FP21, F21 T5	
1025
FP14, F14 T5	
750
F17 T8 	
650
F25 T8 	
750
F32 T8 (4’)	
1100
F40 T8 (5’)	
1325
F48 T8/HO (4’) (44W)	
1100
F60 T8/HO (5’) (55W)	
1275
PL-L 50W, F50BX/RS, FT55DL	
1050
PL-L 40W/RS, F40/30BX, FT40DL/RS	 925
PL-L 36W, F39/36BX, FT36DL	
900

Dimensions
1.18” (3.0cm)

Application
Dual-Lite Lampak UFO-LP Series low-profile fluorescent
emergency ballasts work in conjunction with a low-profile or
standard-size electronic AC ballast containing an end-of-life
shut down circuit to convert new or existing standard or high
output T5 fluorescent fixtures into unobtrusive emergency
lighting. Model UFO-LP1 can be used with one 14 - 28W
standard or 24 - 54W high output T5; one 32W (4’), 40W (5’)
and 44W H0 (4’) T8 fluorescent lamp; or one 36 - 55W (4-pin)
long compact fluorescent lamp (see Table 1). Model UFOLP2 can be used with one 14 - 54W (2’ - 4’) standard or high
output T5, 17 -55W (2’ - 5’) standard or high output T8, 36
- 55W (4-pin) long compact fluorescent lamp (see Table 2).
UFO-LP Series models are also compatible with most 1, 2, 3,
and 4-lamp electronic (including those containing end-of-life
shutdown circuits), standard, energy saving, and dimming AC
ballasts. If used in an emergency-only fixture, no AC ballast is
necessary. UFO-LP Series models are suitable for use in indoordry locations except air handling heated air outlet fixtures,
and wet, damp, or hazardous location fixtures. For information
about specific lamp and ballast compatibility, please contact
the factory.

UFO-LP1 = 18.5” (41.4cm)
UFO-LP2 = 21.5” (54.6cm)
1.18” (3.0cm)

37

Lampak

HID Backup Ballast
Features

UFO-MH
W

NE

An
Severe Conditions Product Line

Damp

• Catches and maintains the arc of
metal halide HID lamps
• Provides two minutes of continuous
arc maintenance
• Maintains lamp at 20-30% normal
operating power
• Multiple catches from one
recharging
• Works with standard constant
wattage autotransformer (CWA)
magnetic ballasts
• 	Compatible with most standard
150 to 400 watt probe-start metal
halide M57, M58 and M59 HID
lamps

• Easy remote installation
• Battery case made of heavy 22gauge steel
• Reliable, high-frequency inverter
• Premium sealed nickel-cadmium
battery
• Universal 120/277VAC operation
• 	LED charge indicator light
• Low power consumption
•	 Temperature range: 	0°C to 55°C 	
	
(32°F to 131°F)
• 	UL 924 Listed (Auxiliary Lighting)
• 	UL Damp Location Listed

Ordering Information
UFO-MH175
UFO-MH250
UFO-MH400

Options (Add suffix to model)
Product Selector Guide
	
	
	
	

Base	

Catalog	
Number	

Maximum	
Distance From	
Lamp	

Maintenance	
Period	

	
	
	

UFO-MH175	
UFO-MH250	
UFO-MH400	

30 Feet	
50 Feet	
80 Feet	

2 Minutes	
2 Minutes	
2 Minutes	

Arc

Accessories

(Order Separately)

Electrical
Lamp Types	
Operated	
175W or 150W energy saving MH (M57)	
250W or 225W energy saving MH (M58)	
400W or 360W energy saving MH (M59)

Input
Wattage
6W @ 120VAC

6W @ 120VAC
10W @ 277VAC
10W @ 277VAC

Application
The Dual-Lite Lampak UFO-MH Series devices are
battery-operated backup ballasts that catch and
maintain the arc of one metal halide HID lamp
during AC power sags, interruptions or failures.
The UFO-MH Series device works in conjunction
with standard constant wattage autotransformer
(CWA) magnetic ballasts. The UFO-MH device
detects AC power line disturbances and operates
the HID lamp with sufficient power to keep
the lamp arc from extinguishing during power
line disturbances. The lamp arc, in a typical HID
lamp, will extinguish if an AC power failure
persists for more than four milliseconds. The
UFO-MH unit detects AC power line disturbances,
then supplies supplemental power to the lamp
within approximately two milliseconds, thereby
maintaining the lamp arc. The UFO-MH Series is
suitable for damp location use. It is also for use
with listed indoor fixtures EXCEPT air handling
heated air outlets and wet or hazardous location
fixtures. The UFO-MH Series may be used with an
auxiliary generator or inverter power system and
the unit’s two-minute time limit allows more than
ample time for an auxiliary generator to pick up
and support the metal halide lamp for emergency
lighting purposes.

38

Dimensions
12.25”
31.1cm

1.75”
4.4cm

7.25”

18.4cm

Exit Signs
LX Series 	
DK Series 	
LT Series	
NYXC Series	
SMC Series	
Sempra Series 	
Sempra MR 	
Sempra SC 	
Sempra SCWL 	
Sempra SERS 	
NYDC Series 	
LN4X Series	
Freedom LED 	
LEDS Series	
NYX Series	
CMX Series	
LE Series	
LES Series	
NYE Series	
NYES Series	
DEX Series 	

Designer LED Exit Signs...................................................................40
AC Incandescent Exit Signs..............................................................41
Designer Tandem Units. .................................................. 42, 43
New York Tandem Units......................................................... 44
Tandem Units with Side Mounted Heads. ................................ 45
Diecast LED Exit Signs.................................................................... 47
Master/Remote Diecast LED Exit Signs.................................... 48, 49
Severe Conditions Diecast LED Exit Signs............................... 50, 51
Wet Location Diecast LED Exit Signs...............................................52
Recessed Diecast LED Exit Signs......................................................53
New York Diecast LED Exit Signs.....................................................54
Wet Location LED Exit Signs.................................................... 55
Aluminum LED Exit Signs.................................................................56
Low-Profile Aluminum LED Exit Signs...................................... 57
New York LED Exit Signs......................................................... 58
Chicago Exit Signs.................................................................. 59
Recessed Mounting Edge-Lit LED Exit Signs........................... 60, 61
Surface Mounting AC Edge-Lit LED Exit Signs....................... 62, 63
New York Recess Mounted Edge-Lit LED Exit Signs.......................64
New York Surface Mounted Edge-Lit LED Exit Signs.....................65
Special Wording Incandescent Exit Signs.................................. 66

39

LX

Designer LED Exit Signs
Features
All Models
•	 UV-stable thermoplastic housing
•	 Compact, low-profile design
•	 Easy to install
•	 Long-life LED lamps
•	 Bright, even illumination
•	 Red and green letters
•	 Universal single/double face
•	 White and black models offered
•	 Push-in wiring connectors
•	 Universal end/ceiling/wall mount
•	 Universal snap-in, chevron
arrows

An
Damp

Severe Conditions Product Line

Ordering Information

LX	

U		 R	

W	

•	 Damp location listed
•	 120/277VAC, 60 Hz operation
Emergency Models
•	 Solid-state charger with low
voltage disconnect
•	 Maintenance-free NiCad battery
•	 2 hour emergency operation
•	 Test switch and AC-On light
•	 Available with Spectron®
self-testing/self-diagnostic
electronics with time-delay relay                  
(TDR) standard
•	 Temperature range: 	10°C to 40°C       
	 	
(50°F to 104°F)
•	 UL 924 Listed

E		-FAP

Series

Options
Operation

Faces

Blank	 -	 AC Only
E	
-	 Emergency

U	-	 Universal Single/Double Face

Letter Color
Also available in black finish

Housing
Finish

R	-	 Red
G	-	 Green

W	 -	 White
B	 -	 Black

Options
I	 	
-2C	
-FAP  	
-FM	
-AF 	
-DC 	
-24K	
-SA	

(Add

suffix to model)

Spectron self-testing/self-diagnostic electronics
2-circuit operation (2)(6)
Fire alarm panel interface (3)(5)(6)
Flasher module (1)(5)
Audible/Flasher module (1)(5)	
	
Remote DC operation (2)(4)(5)	
	
220-240VAC, 60 Hz. operation
“SALIDA” stencil face

(1)
(2)
(3)
(4)

	For specification with emergency models only.
	For use with AC models only.
	Operates with 24-volt AC or DC fire alarm panels.
	For emergency illumination of sign from remote 6-24 VDC 		
power sources.
(5) 	 -FAP, -FM, -AF or -DC options may not be specified together.
(6) 	-2C and -FAP options may be specified together.

Power Consumption

40

		

120VAC	

277VAC

	 Red AC Only Models	

2.6 watts	

2.6 watts

	 Green AC Only Models	

2.1 watts	

2.1 watts

	 Red Emergency Models	

3.8 watts	

3.8 watts

	 Green Emergency Models	
Power factor, average: .8 (lagging)

3.5 watts	

3.5 watts

Accessories
FX2-E  	 	
FX-E  	 	
PMLXW		
PMLXB	 	
WGLX	 	
WG-MLT		
WGLXC	 	
WGLXE	 	
VRS3	 	

(Order Separately)

Emergency operation conversion module (red)
Emergency operation conversion module (green)
121­­/2” Pendant mounting kit (white)
121­­/2” Pendant mounting kit (black)	
Wire guard (Wall mount)
Wire guard (Wall mount)	
Wire guard (Ceiling mount)	
Wire guard (End mount)
Vandal resistant shield

Dimensions

DK

Incandescent Exit Sign
Features
•	 High impact thermoplastic
housing with steel faceplate
•	 Universal directional chevron
arrow knockouts
•	 Tamper resistant screws supplied
•	 AC illumination provided by two
145V, 15T6 incandes­cent  lamps
•	 May be wall, ceiling or end
mounted
•	 Universal single/double face

•	 White finish
•	 Red letter models
•	 120V standard
•	 Suitable for damp locations
•	 Temperature range:  20°C to 30°C       
	 	
(68°F to 86°F)
•	 UL 924 Listed

An
Severe Conditions Product Line

Damp

Ordering Information
Model Number	

Description	

DKURW	
DKURWE	

120V, AC-Only, single or twin face – universal mount, white finish
120/277V, emergency, single or twin face – universal mount, white finish

Options

(Add

Accessories

suffix to model)

PMEXW	
WG-MLT	
WGLXC	
VRS3	

(Order Separately)

12” pendant stem and canopy kit – white
Wire guard (wall mount)
Wire guard (ceiling or end mount)
Vandal resistant shield

Emergency model with power pack

Dimensions
11” (27.9 cm)
5”
(12.7 cm)

CANOPY
1
/2”
(1.3 cm)

Power Pack

4 3/4”

(12.0 cm)

11” (27.9 cm)

21/2”

1
/2”
(1.3 cm)

8”

(6.4 cm)

(20.4 cm)

7 1/2”
(19.1 cm)

31/4”
(8.3 cm)

(DKURWE model)
51/2”

(14.0 cm)

111/4”(28.6 cm) with power pack
3

2 /8”

(6.0 cm)

1

11 /2” (29.2 cm)

41

LT

Designer Tandem Units
Features
•  Factory assembled emergency
unit/LED exit sign
•  UV-stable thermoplastic housing
•  Eyeball style lighting heads
•  High-output halogen lamps
•  White or black finishes offered
•  Remote capacity and damp
location listed models available
•  120/277VAC, 60 Hz operation
•  Solid-state charger
•  Maintenance-free battery
•  Low-voltage disconnect
•  Test switch and AC-On light
•	 Available with Spectron®
self-testing/self-diagnostic

An
Damp

Severe Conditions Product Line

electronics with time-delay relay                  
(TDR) standard
•	 Long-life LED lamps
•  Bright, even illumination
•  Universal single/double face
•  Red and green letter models
•  Snap-in, chevron arrows
•	 Ceiling or wall mount models
standard. Optional side mounting
requires accessory kit
•	 Temperature range: 20°C to 30°C       
	 	
(68°F to 86°F)
(Damp location models: 10°C to 40°C 	
	
(50°F to 104°F)
•	 UL 924 Listed

Ordering Information

LT	

U		 R	

B	

D		-AF

Series

Options
Application

Faces

Blank	 -	 Standard model
-	 Remote capacity model
3	
- Damp location model
D	

U	-	 Universal Single/Double Face

Letter Color
Housing
Finish

R	-	 Red
G	-	 Green

Also available in black finish

W	 -	 White
B	 -	 Black

Options

(Add

suffix to model)

Accessories

(Order Separately)

Power Consumption
		

120VAC	

277VAC

	 Red Emergency Models	

5.0 watts	

5.0 watts

	 Green Emergency Models	

5.0 watts	

5.0 watts

Dimensions
3 5/8"
(9.2 cm)

Power factor, average: .8 (lagging)

Photometrics

High-Output Halogen Lamp
Horizontal Isofootcandle Distribution
      5W MR-16 Lamp		
      • Standard Lamp for LT unit		
      • 5W Lamp for LZR Remote Fixtures	

10W MR-16 Lamp
• 10W Lamp for
LZR Remote Fixtures	

14 1/4"
(36.2 cm)

17/8" (4.7

5 cm)

13"
(33 cm)

42

LT

Product Selector Guide
		Remote	Damp		
Colors	
	Standard	
Capacity	Location	Exit		Stencil				
	Models	Models(1)	Models	Letters	 Housing	Face(s)	Description
	 LTURW	

LTURW3	

LTURWD	

Red	

White	

White	

Single/double face tandem unit

	 LTURB	

LTURB3	

LTURBD	

Red	

Black	

Black	

Single/double face tandem unit

	 LTUGW	

LTUGW3	

LTUGWD	

Green	

White	

White	

Single/double face tandem unit

	 LTUGB	

LTUGB3	

LTUGBD	

Green	

Black	

Black	

Single/double face tandem unit

(1)	 Operates the integral unit heads plus one additional 5 watt lighting fixture or exit sign.

Options

(Add

Accessories

suffix to model)

I	 	
-0		
-FAP  	

Spectron self-testing/self-diagnostic electronics (4)
Unit supplied without lighting heads (3)
Fire alarm panel interface (1)(2)

-FM	
-AF 	
-24K	
-SA	

Flasher module (2)
Audible/Flasher module (2)	
220-240VAC, 60 Hz operation
“SALIDA” stencil face

	

(1) 	Operates with 24-volt AC or DC fire alarm panels.
(2) 	 -FAP, -FM, or -AF options may not be specified together.
(3)	 Available with remote capacity (LTXXX3) models only.
(4)	 Only available on remote capacity and damp location models.

FTSMKW	
FTSMKB		
PMLZTW	
PMLZTB		

	
	
	
	

(Order Separately)

Side mount field kit (white) (a)
Side mount field kit (black) (a)	
121­­/2” Pendant mounting kit (white)
121­­/2” Pendant mounting kit (black)	

WGTW	 	 	
WGTCE	 	 	
VRS2	 	 	
OMSSW0605	
	 	
	 	
	 	
	 	

Wire guard (Wall mount)	
Wire guard (Ceiling or end mount)	
Vandal resistant shield (b)
Outdoor remote lighting head -  	 	
6 Volt, 5 Watt sealed-beam type lamp White finish

OMSSB0605	
	 	
	 	
	 	
	 	

Outdoor remote lighting head -  	 	
6 Volt, 5 Watt sealed-beam type lamp Black Finish

(a)	 FTSMKW and FTSMKB field kits are required for side mounting on all
models. Accommodates left side mounting only.
(b) 	For use with wall mounted units only.

OMS Series outdoor lighting
heads

Matching Remote Fixtures
A complete line of 6- and 12-volt matching remote fixtures
in single and tandem lamp configurations is available for
use with LZ Series high-capacity units or any other 6- or 12volt DC emergency lighting remote power sources.  
All remote fixtures are offered in black and white textured
finishes with a choice of 5- or 10-watt halogen lamps.
	

	 White			 Black
		Single			Single			

Volts	 Watts

	

LZRSW0605	 	

LZRSB0605	 	

6	

5

	

LZRSW0610	 	

LZRSB0610	 	

6	

10

	

LZRSW1205	 	

LZRSB1205	 	

12	

5

	

LZRSW1210	 	

LZRSB1210	 	

12	

10

43

NYXC

New York City Tandem Unit
Features
•	 Designed to meet New York City
specifications
•	 Heavy 20 gauge metal enclosure
with white or black finish
•	 Exit plaques secured by channels
•	 Single face eight inch high letters
•	 Knockout directional chevron
arrows
•	 Available with two or three fully
adjustable and lockable 7.2 watt
thermoplastic lighting heads
•	 High output LED lamps
•	 Universal 120/277VAC operation

W

NE

•	
•	
•	
•	

Wall mounting
Completely self-contained
90-Minute emergency operation
Environmentally coated, fully
automatic solid state charger
•	 Automatic low voltage battery
disconnect
•	 Charge rate indicator and test
switch
•	 Maintenance free battery
•	 Temperature range: 0°C to 40°C       
	 	
(32°F to 104°F)
•	 Listed to UL 924

Ordering Information

NYXC	 S		 R	

B	

E		

2

Options

Series
Operation

Faces

E	-	 Emergency

S	-	 Single
D	-	 Double

W	 -	 White
B	 -	 Black

R	-	 Red

Options

Number of
Lighting
Heads

Housing
Finish

Letter Color

-0612	

-TR

(Add

12 watt lamps

2	 -	 Two
3	 -	 Three

suffix to model)

(1)

Tamper resistant
Options
(Addoption
suffix to model)
(2)

-TR	

Accessories

(Order Separately)

(1)	 12 watt high-output lamps available on two-headed models only.
(2) Provides two stainless steel tamper resistant locking screws.

Accessories
40G	

(Order Separately)

Wire guard (wall mount)

Dimensions

Power Consumption
	
All Models	

120VAC	
7.0W	

277VAC
7.2W

*	 Wattage figures include LED lamps, transformers and electronics 	
	 power requirements.

Photometrics

Horizontal Isofootcandle Distribution
      Standard 6V, 7.2W SBT Lamp 	

B
A

	

C

A	
B	
C	
D
15 1/2”	
15”	
4 1/4”
	 9 5/8”	
	 24.4 cm	 39.4 cm	 38.1 cm	 10.8 cm
	

44

D

SMC

Combination LED Exit/Emergency Light
Features
•	 Combines emergency light with
energy saving LED exit
•	 Adjustable 5.4 watt incandescent
lampheads
•	 Maintenance-free battery
•	 Dual voltage – 120V/277VAC
•	 Fast, easy installation
•	 Snap together, modular
construction
•	 All components are integral
to the exit housing, including
battery

•	 Accessible compartments add to
ease of maintenance
•	 Consumes as little as 4 watts for
either a single or twin face sign
•	 Uniform illumination of
	 exit legend
•	 Snap-out directional chevrons
•	 Temperature range:
	 20°C to 30°C       
	 (68°F to 86°F)
•	 UL 924 Listed

W

NE

Ordering Information

SMC	 3		 R	
Series

E	

CB		 W
Housing
Finish

Operation
E	 -	 Emergency

W	 -	 White
B	 -	 Black

Faces
3	-	 Universal Single or Double

Mounting
CB	 -	 Ceiling/Back
E	 -	 End

Letter Color
R	-	 Red
G	-	 Green

Available March 1, 2006
Options

(Add

Accessories
41G	

suffix to model)

Accessories

(Order Separately)

(Order Separately)

	 Wire guard (wall or ceiling mount)

Dimensions
End Mount
13 3/8”
(34 cm)

12 1/2”

Ceiling or Back Mount
21 1/2” max.

1

4 /2”

(54.6 cm)

(11.4 cm)

max.

12 1/2”

(31.8 m)

(31.8 cm)

10 1/8”
(13.3 cm)

45

Sempra

Diecast LED Exit Sign
Features

All Models
•	 High-strength cast aluminum
•	 Low-profile architectural styling
•	 5-minute installation
•	 Long-life LED lamps
•	 Bright, even illumination
•	 Red and green letters
•	 Single and double face models
•	 White, black and black or white
with brushed face finishes
•	 Push-in wiring connectors
•	 Universal end/ceiling/wall mount
•	 Break-out, chevron arrows and
TY ON
mounting KOs
N
A
R
AR
S
L
W
E
E
•	 120/277VAC, 60 Hz operation
rdering
nformation
OD
TIM

OLIFE

IM
N

CTRO
LL SPE

Emergency Models
•	 Solid-state charger with low voltage
disconnect
•	 Maintenance-free NiCad battery
•	 2-hour emergency operation
•	 Test switch and AC-On indicator
•	 Available with Spectron® selftesting/self-diagnostic electronics
	 with time-delay relay                  
(TDR) standard
•	 Lifetime warranty on LED strip,
electronics and battery with
Spectron® self-testing/selfdiagnostic models
•	 Temperature range: 	20°C to 30°C       
	 	
(68°F to 86°F)
•	 UL 924 Listed

A

Ordering Information
See Product Selector Guide for available models

Special Wording Diffus-

Options

(Add

suffix to model)

Lifetime Warranty
Sempra cast-aluminum emergency exit signs with the
Spectron self-testing/self-diagnostic electronics system
are guaranteed by Dual-Lite under normal and proper
use, against defects in material and workmanship
for the life of the product. The warranty covers all
electronics,
LED light strip and
battery.
ccessories
(Ounit
rder
Separately)

A

Special Wording Open Face Diffuser Table*
	 Option No.	
	 -SW1	
	 -SW2	
	 -SW3	
	 -SW4	
	 -SW5	
	 -SW6	
	 -SW7	
	 -SW8	
	 -SW9	
	 -SW10	
	 -SW11	
	
	

Description	
TO EXIT	
NOT AN EXIT	
IN USE	
XRAY IN USE	
DARKROOM IN USE	
CAUTION	
DO NOT ENTER	
TEST IN PROGRESS	
ON AIR	
AREA OF REFUGE	
AREA OF REFUGE
(w/wheelchair symbol)

Option No.	
-SW12	
-SW13	
	
-SW14	
-SW15	
-SW16	
-SW17	
-SW18	
-SW19	

Description
AREA OF RESCUE ASSISTANCE
AREA OF RESCUE ASSISTANCE
(w/wheelchair symbol)
ELEVATOR
RESTROOMS	
MEN
MEN (w/symbol)
WOMEN
WOMEN (w/symbol)	

Other special wording diffusers
available, consult factory.

*	 To order special wording diffusers, add Option Number suffix to model number.
Ex: SEDRWE-SW(10)

Power Consumption
	
Red AC Only Models: 	
Green AC Only Models: 	
Red Emergency Models: 	
Green Emergency Models:  	

120VAC	
2.6 watts	
2.1 watts	
3.8 watts	
3.5 watts	

277VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts

*Wattage figures include LED lamps, transformer and electronics power
requirements. LED lamp assemblies (red or green) consume less than 1 watt.
Power factor, average: .8 (lagging)

46

Push-in quick-connect
AC terminals

Universal
wall mounting
KO pattern
Wiring
channel

LED
illumination
strip
Isolated,
grounded
120/277VAC
transformer

Break-out
chevron-style
directional indicators

Charger/transfer
module

Sealed
nickel-cadmium
battery

Sempra

Product Selector Guide

	
AC	Emergency	Number		
Colors	
	Model	Model	
of	Exit		Stencil		
	Numbers	Numbers	Faces	Letters	
Housing	Face(s)
	

SESRW	

SESRWE	

Single	

Red	

White	

White

	

SESGW	

SESGWE	

Single	

Green	

White	

White

	

SESRWN	

SESRWNE	

Single	

Red	

White	

Brushed

	

SESGWN	

SESGWNE	

Single	

Green	

White	

Brushed

	

SESRB	

SESRBE	

Single	

Red	

Black	

Black

	

SESGB	

SESGBE	

Single	

Green	

Black	

Black

	

SESRBN	

SESRBNE	

Single	

Red	

Black	

Brushed

	

SESGBN	

SESGBNE	

Single	

Green	

Black	

Brushed

	

SEDRW	

SEDRWE	

Double	

Red	

White	

White

	

SEDGW	

SEDGWE	

Double	

Green	

White	

White

	

SEDRWN	

SEDRWNE	

Double	

Red	

White	

Brushed

	

SEDGWN	

SEDGWNE	

Double	

Green	

White	

Brushed

	

SEDRB	

SEDRBE	

Double	

Red	

Black	

Black

	

SEDGB	

SEDGBE	

Double	

Green	

Black	

Black

	

SEDRBN	

SEDRBNE	

Double	

Red	

Black	

Brushed

	

SEDGBN	

SEDGBNE	

Double	

Green	

Black	

Brushed

Options
I	
-DC	
-2C	
-FAP	
-FM	
-AF	
-24K	

(Add

suffix to model)

Spectron self-testing/self-diagnostic electronics
Remote DC operation (1)(4)(5)	
2-circuit operation (1)(5)	
Fire alarm panel interface (3)(5)	
	
Flasher module (2)(5)	
Audible/Flasher module (2)(5)	
220/240VAC, 60 Hz. operation	

(1) 	For use with AC models only.
(2) 	For use with emergency models only.
(3) 	Operates with 24-volt AC or DC fire alarm panels.
(4) 	For emergency illumination of sign from remote 6-24 VDC power sources.
(5) 	-DC, -2C, -FAP, -FM, -AF options may not be specified together.

Accessories
SER-E	
SEG-E	
PMCW	
PMCB	
WGLX	
WG-MLT	
WGLXC	
WGLXE	

(Order Separately)

Emergency operation module (red models) *	
Emergency operation module (green models) *
121­­/2” Pendant mounting kit (white)
121­­/2” Pendant mounting kit (black)
Wire guard (Wall mount)
Wire guard (Wall mount)	
Wire guard (Ceiling mount)	
Wire guard (End mount)

* For factory-equipped emergency models, see Product Selector Guide above.

Dimensions

9 1/8”

(23 cm)

10”

(25.5 cm)

11 3/4” (30 cm)
12 5/8” (32 cm)

1 5/8” (4.14 cm)

47

Sempra MR

Master/Remote Diecast LED Exit Signs
Features
All Models
•	 High-strength, low-profile cast
aluminum housing
•	 Supplied as 2-sign,
	 Master/Remote sets
•	 5-minute installation
•	 Long-life LED lamps
•	 Bright, even illumination
•	 Red or green letters
•	 Single and double face models

N
NTY O
A
•	 White, black and black or white
R
R
E WA MODELS
M
with brushed face finishes
I
T
E
N
LIF
RIOnformation
Ordering
T
C
E
P
•	 Push-in wiring connectors
ALL S
•	 Universal end/ceiling/wall mount
•	 Break-out, chevron arrows
•	 120/277VAC, 60 Hz operation

Master Signs
•	 Solid-state charger with low   
voltage disconnect
•	 Maintenance-free NiCad battery
•	 90 minute emergency operation
•	 Test switch and AC-On indicator
•	 Available with Spectron® selftesting/self-diagnostic electronics
	 with time-delay relay                  
(TDR) standard
•	 Lifetime warranty on LED strip,
electronics and battery with
Spectron® self-testing/self-  
diagnostic models
•	 Temperature range: 20°C to 30°C       
	 	
(68°F to 86°F)
•	 UL 924 Listed
Remote Signs
•	 Surface mounts to standard
electrical boxes
•	 Connects to Master sign using
conventional wiring methods

Ordering Information

SEMR	 S		 R	

W	

E		-FAP

Series

Options
Operation

Faces

Blank	 -	 AC Only
E	
-	 Emergency

S	-	 Single
D	-	 Double

OLetter
ptions
Color

R	-	 Red
G	-	 Green

(Add

suffix to model)
Housing
Finish
W	 -	 White
B	 -	 Black
WN	-	 White with brushed face
BN	 -	 Black with brushed face

Lifetime Warranty
Sempra cast-aluminum emergency exit signs with the
Spectron self-testing/self-diagnostic electronics system
are guaranteed by Dual-Lite under normal and proper
use, against defects in material and workmanship
for the
life of the product. The
covers all
ccessories
(Owarranty
rder Separately
)
electronics, LED light strip and unit battery.

A

Dimensions
Master
Signs
9 1/8”

(23 cm)

10”

(25.5 cm)

11 3/4” (30 cm)
12 5/8” (32 cm)

1 5/8”

(4.14 cm)

12 3/8” (31.4 cm)

Remote Signs
5

/8”

(1.6 cm)

9 5/8”

(24.4 cm)

48

Sempra MR

Product Selector Guide

	
AC	Emergency	Number		
Colors	
	Model	Model	
of	Exit		Stencil		
	Numbers	Numbers	Faces	Letters	
Housing	Face(s)
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	

SEMRSRW	
SEMRSGW	
SEMRSRWN	
SEMRSGWN	
SEMRSRB	
SEMRSGB	
SEMRSRBN	
SEMRSGBN	
SEMRDRW	
SEMRDGW	
SEMRDRWN	
SEMRDGWN	
SEMRDRB	
SEMRDGB	
SEMRDRBN	

SEMRSRWE	
SEMRSGWE	
SEMRSRWNE	
SEMRSGWNE	
SEMRSRBE	
SEMRSGBE	
SEMRSRBNE	
SEMRSGBNE	
SEMRDRWE	
SEMRDGWE	
SEMRDRWNE	
SEMRDGWNE	
SEMRDRBE	
SEMRDGBE	
SEMRDRBNE	

Single	
Single	
Single	
Single	
Single	
Single	
Single	
Single	
Double	
Double	
Double	
Double	
Double	
Double	
Double	

Red	
Green	
Red	
Green	
Red	
Green	
Red	
Green	
Red	
Green	
Red	
Green	
Red	
Green	
Red	

White	
White	
White	
White	
Black	
Black	
Black	
Black	
White	
White	
White	
White	
Black	
Black	
Black	

White
White
Brushed
Brushed
Black
Black
Brushed
Brushed
White
White
Brushed
Brushed
Black
Black
Brushed

	

SEMRDGBN	

SEMRDGBNE	

Double	

Green	

Black	

Brushed

Options
I	
-DC	
-2C	
-FAP	
-FM	
-AF	
-24K	
-VTR	

(Add

suffix to model)

Spectron self-testing/self-diagnostic electronics
Remote DC operation (1)(4)(5)
2-circuit operation (1)(5)
Fire alarm panel interface (3)(5)
Flasher module (2)(5)
Audible/Flasher module (2)(5)
220/240VAC, 60 Hz. operation
Vandal/tamper resistant option (6)

Accessories
PMCW	
PMCB	
WGLX	 	
WG-MLT		
WGLXC	 	
WGLXE	 	

(Order Separately)

Pendant mounting kit (white) (a)
Pendant mounting kit (black) (a)
Wire guard (Wall mount) (a)
Wire guard (Wall mount) (a)	
Wire guard (Ceiling mount) (a)	
Wire guard (End mount) (a)

(a) 	For use with Master exit signs only.

(1) 	For use with AC models only.
(2) 	For use with emergency models only.
(3) 	Operates with 24-volt AC or DC fire alarm panels.
(4) 	For emergency illumination of sign from remote 6-24 VDC power sources.
(5) 	-DC, -2C, -FAP, -FM, -AF options may not be specified together.
(6)	 Provides polycarbonate face shield and tamper-proof screws. Meets UL listing
requirements for floor proximity use.

Beveled, low-profile design
on Remote signs meet ADA
requirements and UL Listing
requirements for floor
proximity use with -VTR option

Power Consumption

Sempra MR signs equipped with -VTR
vandal/tamper resistant option shield
and hardware.

	
Red AC Only Models: 	
Green AC Only Models: 	
Red Emergency Models: 	
Green Emergency Models:  	

120VAC	
2.6 watts	
2.1 watts	
3.8 watts	
3.5 watts	

277VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts

*Wattage figures include LED lamps, transformer and electronics power
requirements. LED lamp assemblies (red or green) consume less than 1 watt.
Power factor, average: .8 (lagging)

49

Sempra SC

An

Severe Conditions Diecast LED Exit Signs
Features

All Models
•	 High-strength cast aluminum
•	 Low-profile architectural styling
•	 5-minute installation
•	 Polycarbonate face shield
provides additional protection
against vandalism
•	 Tamper-resistent screws prevent
entry by unauthorized personnel
•	 Long-life LED lamps
•	 Bright, even illumination
•	 Red and green letters
•	 Single and double face models
•	 White, black and black or white
Severe Conditions Product Line
with brushed face finishes
rdering nformation
•	
Push-in wiring connectors
VandalTampering
Damp
Hot
Cold
•	 Universal end/ceiling/wall mount
•	 Break-out, chevron arrows and
TY ON
mounting KOs
N
A
R
LS
WAR
E
E
•	
UL Damp Location listed
D
M
O
I
LIFET
ON M
R
•	
120/277VAC, 60 Hz operation
T
C
E
P

O

I

ALL S

Emergency Models
•	 Solid-state charger with low    
voltage disconnect
•	 Maintenance-free NiCad battery
•	 90 minute emergency operation
•	 Test switch and AC-On indicator
•	 Available with Spectron® selftesting/self-diagnostic electronics
	 with time-delay relay                  
(TDR) standard
•	 Lifetime warranty on LED strip,
electronics and battery with
Spectron® self-testing/self-  
diagnostic models
•	 Temperature ranges:	
	 AC models:	
-20°C to 50°C       
	 	
(-4°F to 122°F)
	 Emergency models: 	 0°C to 40°C       
	 	
(32°F to 104°F)
	 Emergency models
	 with -XTR option: 	 -20°C to 50°C
	 	
(-4°F to 122°F)
•	 UL 924 Listed

Ordering Information
See Product Selector Guide for available models

Lifetime Warranty
Options

(Add

suffix to model)

Sempra SC cast-aluminum emergency exit signs with the
Spectron self-testing/self-diagnostic electronics system are
guaranteed by Dual-Lite under normal and proper use,
ccessories
(Order Separately
against defects
in material and workmanship
for the life of )
the product. The warranty covers all electronics, LED light
strip and unit battery.

A

Push-in quick-connect
AC terminals

Universal wall mounting
KO pattern
Wiring
channel

LED
illumination
strip

Polycarbonate face shield provided
standard on all Sempra SC models

Isolated,
grounded
120/277VAC
transformer

Power Consumption
	
Red AC Only Models: 	
Green AC Only Models: 	
Red Emergency Models: 	
Green Emergency Models:  	

120VAC	
2.6 watts	
2.1 watts	
3.8 watts	
3.5 watts	

277VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts

*Wattage figures include LED lamps, transformer and electronics power
requirements. LED lamp assemblies (red or green) consume less than 1 watt.
Power factor, average: .8 (lagging)

50

Break-out
chevron-style
directional
indicators

Charger/transfer module

Sealed
nickel-cadmium
battery

Sempra SC

Product Selector Guide

	
AC	Emergency	Number		
Colors	
	Model	Model	
of	Exit		Stencil		
	Numbers	Numbers	Faces	Letters	
Housing	Face(s)
	

SCSRW	

SCSRWE	

Single	

Red	

	

White	

White

SCSGW	

SCSGWE	

Single	

Green	

White	

White

	

SCSRWN	

SCSRWNE	

Single	

Red	

White	

Brushed

	

SCSGWN	

SCSGWNE	

Single	

Green	

White	

Brushed

	

SCSRB	

SCSRBE	

Single	

Red	

Black	

Black

	

SCSGB	

SCSGBE	

Single	

Green	

Black	

Black

	

SCSRBN	

SCSRBNE	

Single	

Red	

Black	

Brushed

	

SCSGBN	

SCSGBNE	

Single	

Green	

Black	

Brushed

	

SCDRW	

SCDRWE	

Double	

Red	

White	

White

	

SCDGW	

SCDGWE	

Double	

Green	

White	

White

	

SCDRWN	

SCDRWNE	

Double	

Red	

White	

Brushed

	

SCDGWN	

SCDGWNE	

Double	

Green	

White	

Brushed

	

SCDRB	

SCDRBE	

Double	

Red	

Black	

Black

	

SCDGB	

SCDGBE	

Double	

Green	

Black	

Black

	

SCDRBN	

SCDRBNE	

Double	

Red	

Black	

Brushed

	

SCDGBN	

SCDGBNE	

Double	

Green	

Black	

Brushed

Options
I	
-DC	
-2C	
-FAP	
-FM	
-AF	
-24K	
-XTR	

(Add

suffix to model)

Spectron self-testing/self-diagnostic electronics
Remote DC operation (1)(4)(5)	
2-circuit operation (1)(5)	
Fire alarm panel interface (3)(5)	
Flasher module (2)(5)	
Audible/Flasher module (2)(5)	
220/240VAC, 60 Hz. operation	
Extreme temperature operation (2)(6)	

Accessories
PMCW	
PMCB	
WGLX	 	
WG-MLT		
WGLXC	 	
WGLXE	 	

(Order Separately)

121­­/2” Pendant mounting kit (white)
121­­/2” Pendant mounting kit (black)
Wire guard (Wall mount)
Wire guard (Wall mount)	
Wire guard (Ceiling mount)	
Wire guard (End mount)

(1) 	For use with AC models only.
(2) 	For use with emergency models only.
(3) 	Operates with 24-volt AC or DC fire alarm panels.
(4) 	For emergency illumination of sign from remote 6-24 VDC power sources.
(5) 	-DC, -2C, -FAP, -FM, -AF options may not be specified together.
(6) 	For use with Sempra SC emergency models only (Spectron models excluded).

Dimensions

9 1/8”
(23 cm)

10”
(25.5 cm)

11 3/4” (30 cm)
12 5/8” (32 cm)

1 5/8” (4.14 cm)

51

Sempra SC

Wet Location Environmental LED Exit Sign
Features

Wet Location

W

NE

All Models
•	 Designed for wet location and
high abuse applications
•	 Full neoprene gasket
•	 Durable cast aluminum housing in
black finish
•	 Polycarbonate face shields secured
with stainless hardware
•	 Universal ceiling, end or wall                
surface mounting
•	 120/277VAC operation standard
•	 Bright, even illumination
An
•	 Red and green letter models
•	 Snap-out chevron arrows
Severe Conditions Product Line
•	 High output, long-life LED lamps
rdering nformation
•	 Temperature range:	 0°C to 45°C       
	 	
(32°F to 114°F)
Damp
Corrosive
Wet
Cold*

O

I

*With Heater
Option

Emergency Models
•	 Completely self-contained
•	 Fully automatic, environmentally
coated charger
•	 Maintenance-free NiCad battery
•	 Low voltage disconnect
•	 Test switch and AC-On indicator
•	 90 minute operation
•	 Optional 120 minute operation
•	 Temperature range:  0°C to 45°C       
	 	
(32°F to 114°F)
•	 Temperature range with heater
-40°C to 45°C       
option:	
	 	
(-40°F to 114°F)
•	 Vandal-resistant housing with
tamper-resistant screws
•	 Listed to UL 924

Availability To Be Announced

Ordering Information

SCWL 	 S	
Series

R	

B		

E	
Operation

Faces

Options

Blank	 -	 AC Only
E		 	 -	 Emergency

S	-	 Single
D	-	 Double

Letter Color
R	-	 Red
G	-	 Green

Options

U		-AA

(Add

Mounting
Exit Housing
Color

U -	 Universal

A
(OrdertoSeparately
Occessories
ptions (Add suffix
model) )

-	 Black
suffix Bto
model)
W -	White

-AA	
-FM	
-AR120	
-HTR1	
-HTR2	

Dimensions

(1) 	 -AA, -FM, -HTR1, and -HTR2 options may not be specified together.
(2) 	 For use with emergency models only.

A	
B	
C
	
C	
D	
E
	 4”	
10”	 	 6.2”
9”	
9”	
14”
	 10.2 cm	 25.4 cm	 	 15.8 	cm 22.9 cm	 35.6 cm

	

Accessories
PMSWL	

E

52

B

(Order Separately)

12” Pendant mounting kit

C

D
A

Audible alarm (1)(2)
Flasher module (1)(2)
120 minute emergency operation (2)
Internal heater - 120VAC (1)(2)
Internal heater - 277VAC (1)(2)

Sempra SERS

Recessed Cast Aluminum LED Exit Sign
Features
All Models
•	 High-strength cast aluminum
•	 Compact, low-profile style
•	 Fast, easy installation
•	 Long-life LED lamps
•	 Bright, even illumination
•	 Red and green letters
•	 Rigid, high impact acrylic letter
panel
•	 White, black and black or white
with brushed face finishes
•	 Plug-together wiring connectors
•	 Break-out, chevron arrows and
mounting KOs
•	 120/277VAC, 60 Hz operation

Emergency Models
•	 Solid-state charger with low
voltage disconnect
•	 Maintenance-free NiCad battery
•	 2-hour emergency operation
•	 Test switch and AC-On indicator
•	 Available with Spectron® selftesting/self-diagnostic electronics
	 with time-delay relay                  
(TDR) standard
•	 Lifetime warranty on LED strip,
electronics and battery with
Spectron® self-testing/selfdiagnostic models
•	 Temperature range: 20°C to 30°C       
	 	
(68°F to 86°F)
nformation
•	 UL 924 Listed

Ordering I

N
NTY O
A
R
R
A
DELS
ME W
LIFETI CTRON MO
E
ALL SP

Ordering Information

SERS	 R		 WN	

E	 -AF

Series

Options
Letter Color

Lifetime Warranty

Operation

R	-	 Red
G	-	 Green

Blank	 -	 AC Only
E	
-	 Emergency

Sempra cast-aluminum emergency exit signs with the
Spectron self-testing/self-diagnostic electronics system
are guaranteed by Dual-Lite under normal and proper
use, against defects in material and workmanship
for the life of the product. The warranty covers all
electronics, LED light strip and unit battery.

Housing Finish
W	 -	 White
B	 -	 Black
WN	-	 White with brushed face
BN	 -	 Black with brushed face

Options

I	
-DC	
-2C	
-FAP	
-FM	
-AF	
-VTR	
-LRBB	

(Add

suffix to model)

Spectron self-testing/self-diagnostic electronics
Remote DC operation (1)(4)(5)
2-circuit operation (1)(5)
Fire alarm panel interface (3)(5)
Flasher module (2)(5)
Audible/Flasher module (2)(5)
Vandal/tamper resistant option (6)
Sign assembly less rough-in back box (7)

(1) 	For use with AC models only.
(2) 	For use with emergency models only.
(3) 	Operates with 24-volt AC or DC fire alarm panels.
(4) 	For emergency illumination of sign from remote 6-24 VDC power sources.
(5) 	-DC, -2C, -FAP, -FM, -AF options may not be specified together.
(6)	 Provides polycarbonate face shield and tamper-resistant screws. Meets UL
listing requirements for floor proximity use.
(7)	 Allows ordering of rough-in back box separately for installation prior to sign
shipment. Add “-LRBB” suffix to exit model number if RBB accessory kit is to
be ordered separately.

Accessories

(Order Separately)

RBB	
Rough-in back box kit
WGLX	 	 Wire guard (Wall mount)
WG-MLT		 Wire guard (Wall mount)

Dimensions
Rough-In
Back Box

Power Consumption
	
Red AC Only Models: 	
Green AC Only Models: 	
Red Emergency Models: 	
Green Emergency Models:  	

120VAC	
2.6 watts	
2.1 watts	
3.8 watts	
3.5 watts	

277VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts

9 5/8”
(24.4 cm)

*Wattage figures include LED lamps, transformer and electronics power
requirements. LED lamp assemblies (red or green) consume less than 1 watt.
Power factor, average: .8 (lagging)

53

NYDC

New York City Cast Aluminum LED Exit
Features
AC Models
•	 Designed to meet New York City
specifications
•	 All diecast aluminum construction
•	 White, black and black with
brushed face finishes
•	 Break-out directional chevrons
•	 Single and double face models
with eight inch letters
•	 Wall/ceiling/end mounting
•	 Dual voltage – 120/277VAC
•	 Bright and even illumination
•	 Long-life LED lamps

W

NE

Emergency Models
•	 Long life NiCad battery
•	 90 minute emergency operation
•	 Test switch and AC-On indicator
•	 Environmentally coated, fully
automatic charger
•	 Temperature range: 0°C to 45°C
	 	
	
         (32°F to 113°F)
•	 Listed to UL 924

Ordering Information

NYDC	 S		 R	

B	

A		 -FM
Options

Series
Operation

Faces

A	 -	 AC Only
E	 -	 Emergency

S	-	 Single
D	-	 Double

Housing
Finish

Letter Color

W	 -	 White
B	
-	 Black
BN	 -	 Black with brushed face

R	-	 Red

Options (Add suffix to model)
O
(Add suffix to model)
-FM	ptions
Flasher module
(1)(2)

-AA	

Audible alarm module

Available in white, black and
black with brushed face finishes

Accessories

(Order Separately)

(1)(2)

(1) 	For use with emergency models only.
(2) 	-FM and -AA options may not be specified together.

Accessories
PMNYW	
PMNYB	
WGTW	
WGTCE	

(Order Separately)

Dimensions

Pendant mounting kit (white)
Pendant mounting kit (black)
Wire guard (Wall mount)
Wire guard (Ceiling mount)

B*

A*

C

Power Consumption

* Add 1“ (2.5 cm) for mounting
canopy on ceiling or end mounted models

120VAC	

277VAC

AC Only Models	

2.4W	

2.4W

Emergency Models	

3.4W	

3.5W

	

*	 Wattage figures include LED lamps, transformers and electronics 	
	 power requirements.

54

	

A	

B	

C

2 5/8”
	 11”	
161/4”	
	 27.9 cm	 41.3 cm	 6.7 cm

LN4X

Wet Location LED Exit Signs
Features
AC Models
•	 UL type 4X enclosure for
	 indoor/outdoor use
•	 Easily installed to wall surfaces
•	 Suitable for use in damp, wet,
hose-down and corrosive locations
•	 Polycarbonate housing
•	 120/277VAC operation standard
•	 Bright, even illumination
•	 Red and green letter models
•	 Snap-in chevron arrows
•	 Long-life LED lamps
•	 Temperature range:	 0°C to 40°C       
	 	
(32°F to 104°F)

Emergency Models
•	 Suitable for use in damp, wet and
corrosive locations
•	 Completely self-contained
•	 Fully automatic, solid-state charger
•	 Maintenance-free NiCad battery
•	 Low voltage disconnect
•	 Test switch and AC-On light
•	 Available with Spectron® selftesting/self-diagnostic electronics
	 with time-delay relay                  
(TDR) standard
•	 120 minute operation
•	 Temperature range:	 10°C to 40°C       
	 	
(50°F to 104°F)
nformation
•	 UL 924 Listed

An
Severe Conditions Product Line

Ordering I

Damp

Wet

Vandal &
Tampering

Cold

Corrosive

Ordering Information

LN4X	 R		 W	
Series

E	 -FAP
Operation

Blank	 -	 AC Only
E	
-	 Emergency

Letter Color
R	-	 Red
G	-	 Green

Exit Face
Color

Options

W -	White

Accessories

suffix to model)

(Order Separately)

(1)(2)

		

120VAC	

277VAC

	 Red AC Only Models	

2.6 watts	

2.6 watts

	 Green AC Only Models	

2.1 watts	

2.1 watts

	 Red Emergency Models	

3.8 watts	

3.8 watts

	 Green Emergency Models	

3.5 watts	

3.0 watts

Power factor, average: .8 (lagging)

Dimensions
➤

(1)	 Add “I” Spectron self-testing/self-diagnostic option suffix immediately after base
model number. Example: LN4XRWEI
(2) 	For specification with emergency models only.
(3) 	For use with AC models only.
(4) 	Operates with 24-volt AC or DC fire alarm panels.
(5) 	For emergency illumination of sign from remote 6-24 VDC power sources.
(6) 	 -FAP, -XTRFAP, -FM or -DC options may not be specified together.
(7) 	-2C and -XTRFAP or -FAP options may be specified together.
(8)	 Not for use with self-testing Spectron models.
(9)	 Provides an operating temperature range of -20°C to 50°C (-4°F to 122°F)

Power Consumption

11 3/4”
(29.8 cm)

➤
15 3/4”
➤

Spectron self-testing/self-diagnostic electronics
Extreme temperature operation (2)(8)(9)
2-circuit operation (3)(7)
Fire alarm panel interface (4)(6)(7)
Extreme temperature operation fire alarm          	 	
panel interface (2)(4)(6)(7)(8)(9)
Flasher module (2)(6)
Remote DC operation (3)(5)(6)
Tamper-proof cover screws (includes tool)

➤

I	 	
-XTR	
-2C	
-FAP	
-XTRFAP	
	 	
-FM	
-DC	
-TR	

(Add

(40 cm)
5

16 /8”
(42.2 cm)

➤
➤

➤

Options

5 1/4” ➤

(13.3 cm)

55

Freedom LED

Aluminum LED Exit Signs
Features
Emergency Models
•	 Solid-state charger with low
voltage disconnect
•	 6-volt, maintenance-free battery
•	 User-selectable constant on or
flashing emergency illumination
•	 Up to 12 hour operation
•	 Test switch, AC-On and charge
indicator lights
•	 Temperature range: 	10°C to 40°C       
	 	
(50°F to 104°F)
•	 Damp location listed
•	 UL 924 Listed

All Models
•	 Vinyl-clad aluminum housing
•	 Polycarbonate face shield
standard
•	 Easy to install
•	 Long-life LED lamps
•	 Red and green letters
•	 Single and double face models
•	 Six decorator finishes offered
•	 End, ceiling or wall mount
•	 Snap-out, chevron arrows
•	 Damp location listed
•	 120/277VAC, 60 Hz operation

An
Damp

Severe Conditions Product Line

Ordering Information

LED	

2		 EM	

Series

R	 WW		 -TR

R	-	 Red
G	-	 Green

Available Colors
WW	-	 White
WA	 -	 White with Brushed Aluminum Face
BB	 -	 Black
BA	 -	 Black with Brushed Aluminum Face
TT	 -	 Brass
ZZ	 -	 Antique Brass

Operation
AC	 -	 AC Only
EM	 -	 Emergency

Options

Single 	Double
Face	Face
12 Hours	 8 Hours
6 Hours	 4 Hours

Housing
Finish

1	-	 Single Face
2	-	 Double Face

-TR	
-2C	
-FAP  	
-BPR 	

	
Flashing Mode	
Constant On Mode	

Options

Letter Color

Faces

-DC 	

Discharge Times	

(Add

	

Antique Brass	

Black	

Black/Brushed Face

	

Brass	

White	

White/Brushed Face

Accessories

suffix to model)

Remote DC operation(2)(3)(5)
Tamper resistent screws
2-circuit operation(2)(3)(6)
Fire alarm panel interface (flasher)(4)(5)(6)
Beeper module(1)(6)	
	

(Order Separately)

VRS3	 	 Vandal resistant shield
WGTCE	 	 Wire guard (Ceiling/End mount)	
WGTW	 	 Wire guard (Wall mount)

(1) 	For specification with emergency models only.
(2) 	For use with AC models only.
(3) 	For emergency illumination of sign from remote 12 through 48 VDC 		
power sources.
(4) 	Operates with 24-volt AC or DC fire alarm panels.
(5) 	 -FAP, and -DC options may not be specified together.
(6) 	-2C, -BPR and -FAP options may be specified together.

Dimensions

Power Consumption
		

56

Single Face Models 	
120VAC	

277VAC	

Double Face Models	

		
	 Red AC Only Models	

4.47 watts	 4.47 watts	 6.80 watts	 6.80 watts

120VAC	

277VAC

	 Green AC Only Models	

4.68 watts	 4.64 watts	 6.70 watts	 6.70 watts

	 Red Emergency Models	

4.99 watts	 4.99 watts	 7.27 watts	 7.22 watts

A	

B	

C	

	 Green Emergency Models	 4.96 watts	 4.93 watts	 7.65 watts	 7.67 watts

	 7 1/2”	

8.0”	

31/8”	

Power factor, average: .8 (lagging)

	19 cm	 20 cm	 7.9 cm	 30.8 cm	 32.1 cm	 1.3 cm	 15.2 cm	 10.8 cm

	

D	

E	

121/8”	 12 5/8”	

F	

G	

H

1/ 2”	

6.0”	

41/4”

LEDS

Low-Profile Aluminum LED Exit Signs
Features
Emergency Models
•	 Solid-state charger with low
voltage disconnect
•	 Maintenance-free Ni-Cad battery
•	 90-minute emergency operation
•	 Test switch and AC-On indicator
light
•	 Temperature range: 	10°C to 40°C       
	 	
(50°F to 104°F)
•	 Damp location listed
•	 UL 924 Listed

All Models
•	 Vinyl-clad aluminum housing
•	 Compact, low-profile style
•	 Easy to install
•	 Long-life LED lamps
•	 Red and green letters
•	 Single, double and universal
single/double face models
•	 Six decorator finishes offered
•	 End, ceiling or wall mount
•	 Snap-out, chevron arrows
•	 Damp location listed
•	 120/277VAC, 60 Hz operation

An
Damp

Severe Conditions Product Line

Ordering Information

LEDS	 U		 AC	
Series

R	

Options

Letter Color
R	-	 Red
G	-	 Green

Faces

WW	-	 White
WA	 -	 White with Brushed Aluminum Face
BB	 -	 Black
BA	 -	 Black with Brushed Aluminum Face
TT	 -	 Brass
ZZ	 -	 Antique Brass

Operation
AC	 -	 AC Only
EM	 -	 Emergency

Options

(Add

	

Antique Brass	

Black	

Black/Brushed Face

	

Brass	

White	

White/Brushed Face

Housing
Finish

1	-	 Single Face
2	-	 Double Face
U	-	 Universal Single/Double Face

-TR	

Available Colors

BA		 -TR

Accessories

suffix to model)

Tamper resistent screws

VRS3	 	
WGLX	 	
WGLXC	 	
WGLXE	 	

(Order Separately)

Vandal resistant shield
Wire guard (Wall mount)
Wire guard (Ceiling mount)	
Wire guard (End mount)

Dimensions
A	
B	
C	
D	
E	
F	
G	
H
6.0”	
4 1/4”
  	7 1/ 2”	 8.0”	 1 5/8”	 12 1/8”	 12 5/8”	 1/ 2”	
	19 cm	 20 cm	 4.1 cm	 30.8 cm	 32.1 cm	 1.3 cm	 15.2 cm	 10.8 cm
	

57

NYX

New York City LED Exit Sign
Features
AC Models
•	 Designed to meet New York City
specifications
•	 20 gauge metal enclosure
•	 White or black finish
•	 Break-out directional chevrons
•	 Universal single/double face
models with eight inch letters
•	 Wall/ceiling/end mounting
•	 Dual voltage – 120/277VAC
•	 Bright and even illumination
•	 Long-life LED lamps

W

NE

Emergency Models
•	 Long life NiCad battery
•	 90 minute emergency operation
•	 Test switch and AC-On indicator
•	 Environmentally coated, fully
automatic charger
•	 Temperature range: 0°C to 45°C
	          	
(32°F to 113°F)
•	 Listed to UL 924

Ordering Information

NYX	

U		 R	

W	

E		 -FM
Options

Series
Operation

Faces

A	 -	 AC Only
E	 -	 Emergency

U	-	 Universal single/double face

Housing
Finish

Letter Color
W	
B	

R	-	 Red

Options
-FM	
-AA	
-TR	

(Add

-	 White
-	 Black

suffix to model)

(1)(2)

Flasher module
Audible alarm module (1)(2)
Tamper resistant option (3)

Accessories
PMNYW	
PMNYB	
WGTW	

(1) 	For use with emergency models only.
(2) 	-FM and -AA options may not be specified together.
(3)	 Provides two tamper-resistant locking screws.

(Order Separately)

Pendant mounting kit (white)
Pendant mounting kit (black)
Wire guard (Wall mount)

Dimensions
B*

A*

Power Consumption
	
AC Only Models	
Emergency Models	

120VAC	
2.4W	
3.4W	

277VAC
2.4W
3.5W

*	 Wattage figures include LED lamps, transformers and electronics 	
	 power requirements.

58

C
* Add 1“ (2.5 cm) for mounting
canopy on ceiling or end mounted models
A	
B	
C
23/8”
	 101/2”	 141/2”	
	 26.7 cm	 36.8 cm	 6.0 cm

	

CMX

Chicago Low Profile Exit Sign
Features
All Models
• 	City of Chicago approved
•	 22-gauge metal enclosure with
white or black finish
• 	Translucent glass diffuser
• 	Six-inch letters
• 	Full length, silkscreened
directional arrows
• 	Standard, incandescent AC lamps
(Fluorescent lamps optional)
• 	Standard 120 VAC (277 VAC
optional on AC models)
• 	Wall, end or ceiling mounting
• 	Downlighting aperture

Emergency Models
•	 Completely self-contained
emergency power pack
• 	120-minute operation
• 	Fully automatic, solid-state charger
• 	Automatic, low-voltage          
battery disconnect
• 	AC-On indicator and test switch
• 	Maintenance-free long-life leadacid battery
• 	Universal 120/277VAC operation
• 	UL Listed

W

NE

City of Chicago Approval No. 9823

Ordering Information

CMX	 S		 E	

6	 -AF
Options

Series
Faces
S	-	 Single Face
D	-	 Double Face

Exit Legend
Single face models
3	 -	 “EXIT” (no arrows)
6	 -	 “EXIT” (right arrow)
9	 -	 “EXIT” (left arrow)
12	 -	 “EXIT” (double arrow)
2	 -	 “STAIRS” (no arrows)
5	 -	 “STAIRS” (right arrow)
8	 -	 “STAIRS” (left arrow)
11	 -	 “STAIRS” (double arrow)

Operation
Blank	-  AC Only
E	 -	    Emergency

Options
-277V	
-DC6	
-DC12	
-B	
-FL	
-FAP 	
-AF	
-PH	
(1)
(2)
(3)
(4)
(5)

(Add

suffix to model)
(1)

277 VAC operation
6 VDC emergency socket and lamp (1)
12 VDC emergency socket and lamp (1)
Black finish
7 watt fluorescent AC lamps
Fire alarm panel interface (2)(3)(4)
Audible flasher alarm (3)(4)(5)
Phosphorescent glass diffuser panel

For use with AC models only.
Operates with 24-volt AC or DC fire alarm panels.
-FAP and -AF options may not be specified together.
-FAP and -AF options not available with fluorescent lamp models.
-AF option for use with emergency models only.

Double face models
18	 -	 “EXIT” (no arrows)
21	 -	 “EXIT” (right/left arrow)
24	 -	 “EXIT” (double arrow)
17	 -	 “STAIRS” (no arrows)
20	 -	 “STAIRS” (right/left arrow)
23	 -	 “STAIRS” (double arrow)

Accessories
CKW	
CKB	
PMKW	
PMKB	
WGMLT	
WGTW	
WGTCE	
	
VRS2	

(Order Separately)

Canopy mounting kit (white)
Canopy mounting kit (black)
Pendant mounting kit (white)
Pendant mounting kit (black)
Wire guard (wall mount - AC models)
Wire guard (wall mount - emergency models)
Wire guard (ceiling/end mount - AC and 	
	
emergency models)
Vandal resistant shield (fits all models)

Dimensions

Power Consumption
		
		
	 AC Only Exits	
	 Emergency Exits	

Incandescent Models 	

Fluorescent Models

120/277VAC	
40 watts	

120/277VAC
18 watts

50 watts	

28 watts

C
B

A
A	
B	
C	
91/2”	
141/2”	
	 12 3/4”	
	32.4 cm	 24.1 cm	 36.8 cm	
	

D
D
21/2”
6.4 cm

59

LE

Recessed Mounting Edge-Lit LED Exit Signs
Features
AC Models
•	 Ceiling, wall or end mounted
models for recessed installations
•	 Extruded aluminum construction
•	 Available in six color finishes
•	 Molded acrylic plaque
•	 Red and green letter models
•	 Clear, white or mirror
background
•	 Silkscreened chevron arrows
•	 Long life LED lamps
•	 Bright, even letter illumination
•	 Energy-saving operation
•	 Universal rough-in box

•	 Easy to install
•	 120/277VAC, 60 Hz operation
Emergency Models
•	 Solid-state charger
•	 Maintenance-free NiCad battery
•	 Low voltage disconnect
•	 Test switch and AC-On light
•	 Available with Spectron® selftesting/self-diagnostic electronics
	 with time-delay relay                  
(TDR) standard
•	 Temperature range: 20°C to 30°C       
	 	
(68°F to 86°F)
•	 UL 924 Listed

Ordering Information

	 LE	

C		 D	

Series

R	

C		 N	
Directional
Arrows

LE	 -	 Recessed 	
	
	 mount
	
	

X	-	 No arrows EXIT
R	-	 Right arrow* 		
		 EXIT>
L	 -	 Left arrow* 
C	-	 L/R arrows**
	 	

Mounting
C	 -	 Ceiling mount
W	 -	 Wall mount
E	 -	 End mount

* Not for use with double
face models. Use “C” L/R
arrow designator
** Double face models only.
Provides reversible right
or left arrow indicator

Faces
S	-	 Single
D	-	 Double*

Options

(Add

* Not for use with wall mounted models

suffix to model)

E		-FM	
Operation

A	 -	 AC only
E	 -	 Emergency

Options
See “Options” section

Standard Plaque Backgrounds
Single face models = clear
Double face models = mirror
-	 Satin Aluminum
-	 White
See “Options” for alternate   
-	 Chrome
backgrounds.
-	 Black
ccessories (Order Separately)
-	 Satin brass

Trim/Housing
Finish

N	
W	
C	
B	
S	
Z	 -	 Dark Bronze

A

Letter Color
R	-	 Red
G	-	 Green

Satin Aluminum

White

Chrome

Black

Satin Brass

Dark Bronze

Wall mount model

Power Consumption
	
Single 	Double
	Face	Face
Red AC Only Models	
2.2W	
3.7W
Green AC Only Models	

2.5W	

4.4W

Red Emergency Models	
Green Emergency Models 	

3.3W	
3.6W	

4.7W
5.2W

*	 Wattage figures include LED lamps, transformers and electronics 	

60

End mount model

Options
I	 	
-XK	
-W	
-M	
-8L	
-2C	
-FAP	
-FM	
-AF	
-DC	
-24K	

(Add

suffix to model)

Spectron self-testing/self-diagnostic electronics
Recessed mount exit sign less rough-in kit (1)	
White plaque background	
Mirror plaque background (2)
8 inch letter plaque (red letters only) (10)(11)	
2-circuit operation (3)(8)
Fire alarm panel interface (5)(7)(8)	
Flasher module (4)(7)
Audible/flasher module (4)(7)
Remote DC operation (3)(6)(7)	
220/240VAC, 60 Hz operation (9)	

(1) 	 Allows ordering of rough-in kit separately for recessed mount (LE) models.
See “Accessories”.
(2) 	 For use with single face models only. Standard on double face models.
(3) 	 For use with AC models only.
(4) 	 For specification with emergency models only.
(5) 	 Operates with 24-volt AC or DC fire alarm panels.
(6) 	 For emergency illumination of sign from remote 6-24 VDC power sources.
(7) 	 -FAP, -FM, -AF or -DC options may not be specified together.
(8) 	 -2C and -FAP options may be specified together.
(9) 	 Rough-in kit may not be ordered separately on models specified with -24K
option.
(10)	 LE exit models with 8” plaques registered under NYC-BEC Calendar Number
42135 for use in New York City.
(11)	 Single face LE exit signs specified with the -8L option are supplied without
backgrounds. Double face models specified with the -8L option are supplied
with mirror backgrounds.	

Accessories

LE

(Order Separately)

URK	
Universal rough-in kit (b)  
URK2C	 Universal 2-circuit rough-in kit (a)(b)(c)

(a) 	 For use with AC models only.
(b) 	 Rough-in kit may not be ordered separately on models specified
with -24K option.
(c) 	 Must be ordered in conjunction with -2C option on exit sign

To Order Rough-In Kit Separately
To order rough-in kit only for early installation, add
“-XK” option suffix to exit model number and order
“URK” or “URK2C” kit separately.
		

Universal Rough-In Kit

Dimensions
Rough-In Kit

Ceiling Mount Application

End Mount Application

Wall Mount Application

61

LES

Surface Mounting AC Edge-Lit LED Exit Signs
Features
•	 Long life LED lamps
•	 Bright, even letter illumination
•	 Energy-saving operation
•	 Easy to install
•	 120/277VAC, 60 Hz operation
•	 Temperature range: 20°C to 30°C       
	 	
(68°F to 86°F)
•	 UL Listed

AC Models
•	 Ceiling, wall or end mounted
models for surface installations
•	 Extruded aluminum construction
•	 Available in six color finishes
•	 Molded acrylic plaque
•	 Red and green letter models
•	 Clear, white or mirror
background
•	 Silkscreened chevron arrows

Ordering Information

LES	

C		 S	

Series

C		 N	
Directional
Arrows

LES	 -	 Surface 	
	
	 mount 	
	
	

Mounting

* Not for use with double
face models. Use “C” L/R
arrow designator
** Double face models only.
Provides reversible right
or left arrow indicator

Faces

Options

A		 -M	
Operation

A	 -	 AC only

X	-	 No arrows EXIT
R	-	 Right arrow* 		
		 EXIT>
L	 -	 Left arrow* 
C	-	 L/R arrows**
	 	

C	 -	 Ceiling mount
W	 -	 Wall mount
E	 -	 End mount

S	-	 Single
D	-	 Double*

R	

(Add

* Not for use with wall mounted models

suffix to model)

Options
See “Options” section

Standard Plaque Backgrounds
Single face models = clear
Double face models = mirror
-	 Satin aluminum
-	 White
See “Options” for alternate back-	 Chrome
grounds.
-	 Black
ccessories (Order Separately)
-	 Satin Brass

Trim/Housing
Finish

N	
W	
C	
B	
S	
Z	 -	 Dark bronze

A

Letter Color
R	-	 Red
G	-	 Green

Satin Aluminum

White

Chrome

Black

Satin Brass

Dark Bronze

Power Consumption
	
Single 	Double
	Face	Face
Red AC Only Models	
2.5W	
4.0W
Green AC Only Models	
2.6W	
4.5W
*	 Wattage figures include LED lamps, transformers and electronics 	
	 power requirements.

62

End mount model

Options
-W	
-M	
-8L	

(Add

LES

suffix to model)

White plaque background	
Mirror plaque background (1)
8 inch letter plaque (red letters only) (2)(3)	

(1) For use with single face models only. Standard on double
face models.
(2)	LES exit models with 8” plaques registered under NYC-BEC Calendar
Number 42135 for use in New York City.
(3)	Single face LES exit signs specified with the -8L option are supplied
without backgrounds. Double face models specified with the -8L option are supplied with mirror backgrounds.
	

Ceiling mount model

Dimensions

Ceiling Mount Application

Wall Mount Application

End Mount Application

63

NYE

New York City Recessed Edge-Lit Exit
Features
AC Models
•	 Designed to meet New York City
specifications
•	 Recessed ceiling or wall mount
models
•	 Extruded aluminum construction
•	 Available in two color finishes
•	 Acrylic plaque
•	 Eight-inch red letter models
•	 Clear, white or mirror
background
•	 Applique chevron arrows
•	 Long life LED lamps

W

NE

•	 Bright, even letter illumination
•	 Energy-saving operation
•	 Easy to install
•	 120/277VAC, 60 Hz operation
Emergency Models
•	 Environmentally coated, fully
automatic charger
•	 Maintenance-free NiCad battery
•	 Low voltage disconnect
•	 Test switch and AC-On indicator
•	 Temperature range: 	0°C to 45°C       
	 	
(32°F to 113°F)
•	 Listed to UL 924

Ordering Information

	NYE 	 C 	

	 D	

R	 N	

E	 -W	

Operation

Series

A	 -	 AC only
E	 -	 Emergency

NYE	-	 Recessed 	
	
	 mount 	
Mounting
	
	
C	 -	 Ceiling
W	 -	 Wall

Trim/Housing
Finish

Options
See “Options” section

N	 -	 Satin aluminum
W	 -	 White

Faces
S	-	 Single
D	-	 Double*
* Not for use with wall mounted models

Letter Color
R	-	 Red
Options
(Add suffix to model)

Options

(Add

(Order Separately)

suffix to model)

-LRBB	
-W	
-M	

Recessed mount exit sign less rough-in backbox (1)
White exit face background
Mirrored exit face background

(1) 	

Allows ordering of rough-in backbox separately. See “Accessories”. 	

Accessories

Accessories
Dimensions

D

(Order Separately)

NYC-RBB	 Rough-in backbox

E
F

Power Consumption
	

120VAC	

277VAC

AC Only Models	

3.2W	

3.2W

Emergency Models	

4.0W	

3.9W

B
A

*	 Wattage figures include LED lamps, transformers and electronics 	

C
	
A	
B	
C	
D	
E	
F	
G
H
131/2”	
14”	
165/8”	 173/8”	      193/16”      305/8”      23/4”
	
93/4”	
	 24.8 cm	 34.2 cm	 35.6 cm	 42.2 cm	 44.1 cm	 48.8 cm	 77.8 cm 7.0 cm

64

NYES

New York City Surface Edge-Lit Exit
Features
AC Models
•	 Designed to meet New York    
City specifications
•	 Surface mount design
•	 Wall, ceiling or end           
mounted models
•	 Extruded aluminum construction
•	 Available in two color finishes
•	 Acrylic plaque
•	 Eight-inch red letter models
•	 Clear, white or                       
mirror background
•	 Applique chevron arrows
•	 Long life LED lamps

•	 Bright, even letter illumination
•	 Energy-saving operation
•	 Easy to install
•	 120/277VAC, 60 Hz operation
Emergency Models
•	 Environmentally coated, fully
automatic charger
•	 Maintenance-free NiCad battery
•	 Low voltage disconnect
•	 Test switch and AC-On indicator
•	 Temperature range: 	0°C to 45°C       
	 	
(32°F to 113°F)
•	 Listed to UL 924

W

NE

Ordering Information

	NYES 	 C 	

D	 R	

N	

E	

-W	

Operation

Series

A	 -	 AC only
E	 -	 Emergency

NYES	 -	 Surface 	
	
	 mount 	
	
	

Mounting

C	 -	 Ceiling
W	 -	 Wall
E	 -	 End

Trim/Housing
Finish

Options

N	 -	 Satin aluminum
W	 -	 White

Faces

See “Options” section

S	-	 Single
D	-	 Double*
* Not for use with wall mounted models

Letter Color
R	-	 Red
Options
(Add suffix to model)

Options
-W	
-M	

(Add

Accessories

(Order Separately)

Dimensions

suffix to model)

White exit face background
Mirrored exit face background

D
E

F
B
A

Power Consumption
	

120VAC	

277VAC

AC Only Models	

3.2W	

3.2W

Emergency Models	

4.0W	

3.9W

*	 Wattage figures include LED lamps, transformers and electronics 	

C
A	
B	
C	
D	
E	
F
14”	
17”	
165/8”	   21/4”
       10”	
131/2”	
	 25.4 cm	 34.3 cm	 35.6 cm	 43.2 cm	 42.2 cm	 5.7 cm

65

DEX

Special Wording Incandescent Signs
Features
AC Models
•	 Thermoplastic housing
•	 Steel faceplate
•	 Polyester fiberglass special    
wording open face diffuser
•	 Acrylic downlight lens
•	 Canopy for ceiling or end mount
•	 Universal directional chevron
arrow knockouts
•	 Tamper resistant screws supplied
•	 120V standard
•	 AC illumination provided by two
145V, 15T6 incandes­cent  lamps

•	 Suitable for damp locations (AC
models only)
Emergency Models
•	 Maintenance-free battery
•	 High impact housing
•	 Dual voltage – 120V/277VAC
•	 Two 6V, 3.7W DC lamps for
emergency operation
•	 Temperature range: 20°C to 30°C       
	 	
(68°F to 86°F)

Ordering Information

DEX	 1		EMFA	 R	
Series

Background
Color
R	 – Red
G	 – Green
W	 – White

Faces
1	-	 Single
2	-	 Double

Special
Wording
Option No.

Operation
Letter
Color

Blank	 – AC-Only 120VAC
EMFA	 – Emergency 120/277VAC
R	
G	
W	
B	

Options

(Add

See table at
right

– Red
– Green
– White
– Blue

	 Option
	 No.*	
	 -SW1 	
	 -SW2 	
	 -SW3 	
	 -SW4	
	 -SW5	
	 -SW6 	
	 -SW7 	
	 -SW8	
	 -SW9 	
	 -SW10	
	 -SW11	
	
	
	 -SW12 	
	 -SW13	
	 	
	 -SW14	
	 -SW15	
	 -SW16	
	 -SW17	
	 -SW18	
	 -SW19	

Description
TO EXIT
NOT AN EXIT
IN USE
XRAY IN USE
DARKROOM IN USE
CAUTION
DO NOT ENTER
TEST IN PROGRESS
ON AIR
AREA OF REFUGE
AREA OF REFUGE
(w/wheelchair symbol)
AREA OF RESCUE ASSISTANCE
AREA OF RESCUE  ASSISTANCE
(w/wheelchair symbol)
ELEVATOR
RESTROOMS
MEN
MEN (w/symbol)
WOMEN
WOMEN (w/symbol) rder

Accessories

suffix to model)

Accessories
WG-MLT	
WGLXC	
WGTCE	
PMEXW	
PMEXB	
VRS3	

Special Wording Table

W		-SW3

(O

Separately)

Other Special Wording models available.  Consult Factory.
*	 To order special wording diffusers, add Option Number suffix
to model number. Ex: DEX1EMFARW-SW10

(Order Separately)

Wire guard (wall mount - all models)
Wire guard (ceiling mount - AC models only)
Wire guard (end mount - all models)
12” pendant stem and canopy kit – white
12” pendant stem and canopy kit – black
Vandal resistant shield

Dimensions
11” (279 mm)
5”
(127 mm)

CANOPY
1
/2”
(13 mm)

4 3/4”
(120 mm)

Power Pack
11” (279 mm)

2 1/2”
(64 mm)

8”
(204 mm)
7 1/2”
(191 mm)

5 1/2”
(140 mm)
11 1/2” (292 mm)

66

3 1/4”
(83 mm)

(EMFA models)
3

2 /8”
(60 mm)

1
/2”
(13 mm)

SlimLite Series 	
CV Series 	
CVEC Series	
CV3 Series 	
CVT Series	
CVD Series 	
CVER Series	

Fixed Lens Emergency Lights................................................... 68
Emergency Lights................................................................... 69
High Capacity Emergency Lights.............................................. 70
LED Exit Signs..................................................................................71
Tandem Units. ....................................................................... 72
Diecast LED Exit Signs......................................................................73

67

Recessed Mounting Edge-Lit LED Exit Signs...................................74

SlimLite

Contemporary Emergency Light
Features
•	 Easy to install
•	 Sleek, low profile design
•	 Flame rated, UV stable
thermoplastic housing
•	 Bright white finish
•	 6 volt, T-5 incandescent lamps
•	 Acrylic fresnel lens provides a
	 focused beam pattern
•	 Adjustable lamp socket  
•	 Maintenance-free battery
•	 Universal 120/277VAC operation

12W

•	 Fully-automatic, temperature-	 	
compensated, solid-state charger
•	 Reverse polarity and short circuit
protection
•	 AC lockout
•	 Low-voltage battery disconnect
•	 Test switch and AC-On light
•	 Temperature range: 	20°C to 30°C       
	 	
(68°F to 86°F)
•	 Meets ADA specifications
•	 UL 924 Listed

Ordering Information
	 Standard Model	
	 	
SL1			

Voltmeter Model
SL1-V

Also available in black finish

Options
(Add
suffix
catalogto
number)
O
ptions
(A
dd to
suffix
model)
-B		
-6H 	

Accessories

(Order Separately)

	 Vandal resistant shield
VRS 	
WGLZ 	 	 Wire guard

Black housing
6 watt halogen lamps

Product Selector
Options (Add suffix to model)

Accessories

		Electrical

(Order Separately)

	 Base	Output Watts	
AC Input	
	 Catalog	Output	
1.5	
2	
3	
4				Standard	Remote
	Number	
Volts	
Hours	 Hours	 Hours	 Hours	
Volts	
Amps	
Watts	Lamp	 Capability
	SL1, SL1-V	
	
	

6	
	

12.0	
	

--	
	

--	
	

	
-	

120	

.050	

6.0	

277	

.020	

6.0	

5.4W	

No

Dimensions
5 1/8”
(13 cm)

TEST/ESSAI
CHARGE

11 3/4”
(30 cm)

68

2 1/4” (5.7cm)

Designer Emergency Light
Features
•	 Fast, easy installation
•	 Snap-together design
•	 Compact, low-profile style
•	 Injection molded high impact, UV  	
stabilized thermoplastic
•	 White finish
•	 Standard and damp location
models
•	 Remote capacity models
•	 High output incandescent lamps
•	 Maintenance-free battery

•	 Dual voltage – 120/277VAC
•	 Fully automatic charger
•	 Automatic low-voltage battery
disconnect and transformer
isolation protection
•	 Universal mounting plate
•	 Test switch and LED AC-On light
•	 Temperature range: 	20°C to 30°C       
	 	
(68°F to 86°F)
	 Damp location models: 	 10°C to 40°C       
	 	
(50°F to 104°F)
•	 UL 924 Listed

Ordering Information
Standard
Models:		Information
CV2 (6V, 12W)
		
CV3
(6V, 18W)	
Ordering
Example:
EDS4-EV1
Damp Location Models:	

Options
-V		

CV2D (6V, 12W)	

(Add

CV

11W to 30W

CV3D (6V, 18W)	

W

NE

CV5 (6V, 30W)
CV5D (6V, 30W)	

Accessories

suffix to model)

Voltmeter

(Order Separately)

SRHSW0605	 Matching remote head - single (white)	
SRHDW0605	 Matching remote head - twin (white)
OMSSB0605	 Single outdoor lighting head (black)
OMSDB0605	 Twin outdoor lighting head (black)
PMLZTW	 	
Pendant mounting kit (white) (a)
PMLZTB		 Pendant mounting kit (black) (a)
WGEL	 	 	
Wire guard
(a) 	Not available for use with CV5 and CV5D models.

Options

(Add

Matching
remote head

Accessories

suffix to model)

Outdoor
lighting head

(Order Separately)

Product Selector
	
Base	
	 Catalog 	Output		
	Number	
Volts	 1.5 Hrs.	

Electrical
Output Watts		
2 Hrs.	
3 Hrs.	
4 Hrs.	

Input Amps	Input Watts	Standard	Remote
120V	 277V	 120/277V	Lamp	
Capability

	

CV2	

6	

12	

--	

--	

--	

.040	

.020	

4.0	

5.4W	

No

	

CV3	

6	

18	

13	

--	

--	

.040	

.020	

4.0	

5.4W	

Yes

	

CV5	

6	

30	

22	

15	

12	

.130	

.060	

14.0	

5.4W	

Yes

	

CV2D	

6	

11	

--	

--	

--	

.040	

.020	

4.0	

5.4W	

No

	
	

CV3D	
CV5D	

6	
6	

17	
27	

12	
20	

--	
13	

--	
--	

.040	
.130	

.020	
.060	

4.0	
14.0	

5.4W	
5.4W	

Yes
Yes

Photometrics

Dimensions

Horizontal Isofootcandle Distribution
15 7/8”-Min.
19 3/4”-Max.

4 3/4”-Min.
6 3/4”-Max.

(40.3 cm)-Min.
(50.2 cm)-Max.

(12.1 cm)-Min.
(17.1 cm)-Max.

6 Volt, 5.4 Watt SBT Lamp 	

5 3/8”
(13.7 cm)

69

CVEC

Commercial Emergency Light
Features
•	 Injection molded high impact, 	 	
UV stabilized thermoplastic
•	 Standard white housing
•	 T-5 incandescent lamps
•	 Lampheads may be top or side
mounted
•	 Most models capable of powering
remote lampheads
•	 Maintenance-free battery
•	 Dual voltage – 120/277VAC
•	 Automatic low voltage disconnect
•	 Thermally compensated charger

W

NE

15W to 100W

•	 Regulated charge voltage
•	 Automatic low voltage disconnect
•	 Reverse polarity protection
•	 Filtered charger output
•	 Universal wall mounting plate
•	 Short circuit protection
•	 AC lockout
•	 Test switch and AC-On light
•	 Temperature range: 	20°C to 30°C       
	 	
(68°F to 86°F)
•	 UL 924 Listed

Ordering Information
Standard Models:

Options
-V		

CVEC15

(Add

CVEC30

CVEC 50

CVEC50-12V

CVEC100-12V

Accessories

suffix to model)

Voltmeter

(Order Separately)

Wire guard (a)
Wire guard (b)
Matching 6-volt remote head - single
Matching 6-volt remote head - twin
Matching 12-volt remote head - single
Matching 12-volt remote head - twin

40G 	
	 	
41G 	
	 	
SRHSW0607	
SRHDW0607	
SRHSW1207	

	
	
	
	
	
SRHDW1207	 	

(a)	 For top mounted heads on CVEC 15 and 30 watt models
(b)	 For top mounted heads on CVEC 50 and 100 watt models and side mounted
heads on CVEC 15 and 30 watt models.

Options

(Add

Accessories

suffix to model)

(Order Separately)

Product Selector
			
Electrical
	Standard 	 	Output		
Output Watts		
Input Amps	 Input Watts	Standard	Remote
	Models		 Volts	 1.5 Hrs.	 2 Hrs.	 3 Hrs.	 4 Hrs.	 120V	 277V	 120	 277V	Lamp	
Capability
	

CVEC15		

6	

15	

--	

--	

--	

.07	

.03	

8.4	

8.8	

7.2W	

No

	

CVEC30		

6	

30	

22	

15	

12	

.07	

.03	

8.4 	

8.8	

7.2W	

Yes

	

CVEC50		

6	

50	

38	

25	

20	

.17	

.08	

20 	

20	

7.2W	

Yes

	

CVEC50-12V		

12	

50	

38	

25	

20	

.11	

.05	

13	

14	

9.0W	

Yes

	

CVEC100-12V		

12	

100	

76	

54	

44	

.32	

.14	

39	

28	

9.0W	

Yes

Photometrics

Horizontal Isofootcandle Distribution
6 Volt, 7.2 Watt SBT Lamp

70

12 Volt, 7.2 Watt SBT Lamp 	

Dimensions
15 and 30W Models
50 and 100W Models

CV3

Thermoplastic LED Exit Sign
Features
•	 Damp location listed
•	 120/277VAC, 60 Hz operation
Emergency Models
•	 Solid-state charger with low
voltage disconnect
•	 Maintenance-free NiCad battery
•	 2 hour emergency operation
•	 Test switch and AC-On light
•	 Temperature range: 	0°C to 40°C       
	 	
(32°F to 104°F)
•	 UL 924 Listed

All Models
•	 UV-stable thermoplastic housing
•	 Compact, low-profile design
•	 Easy to install
•	 Long-life LED lamps
•	 Bright, even illumination
•	 Red and green letters
•	 Universal single/double face
•	 White finish
•	 Push-in wiring connectors
•	 Universal end/ceiling/wall mount
•	 Universal snap-in,              
chevron arrows

W

NE

Ordering Information

CV	

3		 R	

E	

W		 -2C

Series

Options
Housing
Finish

Faces
3	-	 Universal Single/Double Face

W	 -	 White

Letter Color

Options

Operation

R	-	 Red
G	-	 Green

A	 -	 AC Only
E	 -	 Emergency

Options

(Add

-2C	
-DC 	

suffix to model)

Dimensions
7”

5 3/16”

(17.8 cm)

(13.2 cm)

(Add

suffix to model)
2-circuit operation (1)(3)
Remote DC operation (1)(2)(3)	
	

(1) 	For use with AC models only.
(2) 	For emergency illumination of sign from remote 6-24 VDC 		
power sources.
eparately
(3) -2C and -DC options may not be specified rder
together.

Accessories

(O

Accessories

(Order Separately)

PMLXW		
WGLX	 	
WG-MLT	 	
WGLXC	 	
WGLXE	 	
VRS3	 	

S

)

Pendant mounting kit (white)
Wire guard (Wall mount)
Wire guard (Wall mount)	
Wire guard (Ceiling mount)	
Wire guard (End mount)
Vandal resistant shield

9 3/4”
(24.8 cm)

9”
(22.8 cm)

Power Consumption

13”
(33.0 cm)

1 3/4”
(4.4 cm)

		

120VAC	

277VAC

	 Red AC Only Models	

2.7 watts	

2.7 watts

	 Green AC Only Models	

2.3 watts	

2.3 watts

	 Red Emergency Models	

3.8 watts	

3.8 watts

	 Green Emergency Models	

3.5 watts	

3.5 watts

Power factor, average: .8 (lagging)

71

CVT

Thermoplastic Tandem Unit
Features
•  Factory assembled emergency
unit/LED exit sign
•  UV-stable thermoplastic housing
•  High-output lighting heads
•  White finish
•  Damp location listed           
models available
•  120/277VAC, 60 Hz operation
•  Solid-state charger with lowvoltage disconnect
•  Maintenance-free battery
•  Test switch and LED AC-On light

W

NE

•	 Long-life LED lamps
•  Bright, even illumination
•  Universal single/double face
•  Red and green letter models
•  Snap-in, chevron arrows
•	 Ceiling or wall mounting
•	 Temperature range: 	20°C to 30°C       
	 	
(68°F to 86°F)
	 Damp location models: 10°C to 40°C
	 	
(50°F to 104°F)
•	 UL 924 Listed

Ordering Information

CVT	 3		 R	

W	

5		 D

Series
Faces
3	-	 Universal Single or Double

Blank	 -	 Standard model
- Damp location model*
D	
* Only available on 3-head models

W	 -	 White

Letter Color

Remote Heads

R	-	 Red
G	-	 Green

Blank 	 - No remote capability
- Operates one additional  	
3	
	
  5.4 watt remote head
5	
- Operates up to three 	 	
  additional 5.4 watt
	
                remote heads

Options
	
Input Amps	
Input Watts	

Application

Housing
Finish

(Add

suffix to model)
120VAC	 277VAC
.05	
.02
5.0
5.0	

Accessories

(Order Separately)

SRHSW0605	 	 Matching remote head - single (white)	
SRHDW0605	 	 Matching remote head - twin (white)
ccessories (Order Separately)
OMSSB0605	 	 Single outdoor lighting head (black)
OMSDB0605	 	 Twin outdoor lighting head (black)
PMLZTW	 	 	 Pendant mounting kit (white) (a)
WGTW	 	 	 	 Wire guard (Wall mount)	
WGTCE	 	 	 	 Wire guard (Ceiling mount)	

A

(a) 	Not available for use with 5-head models

Dimensions
15 7/8”-Min.
19 3/4”-Max.

4 3/4”-Min.
6 3/4”-Max.

(40.3 cm)-Min.
(50.2 cm)-Max.

(12.1 cm)-Min.
(17.1 cm)-Max.

Photometrics

Horizontal Isofootcandle Distribution
6 Volt, 5.4 Watt SBT Lamp 	

14 3/8”
(36.5 cm)

9”
(22.8 cm)

13”
(33.0 cm)

1 3/4”
(4.4 cm)

72

CVD

Cast Aluminum LED Exit Sign
Features
AC Models
•	 All diecast aluminum construction
•	 Soft edges and corners
•	 White and black with brushed
face finishes
•	 Break-out directional chevrons
•	 Universal mounting KO pattern
•	 Back/ceiling/end mounting
•	 Dual voltage – 120/277VAC
•	 Bright and even illumination
•	 Long-life LED lamps

Emergency Models
•	 Long life NiCad battery
•	 90 minute emergency operation
•	 Test switch and AC-On indicator
•	 Reverse polarity, short circuit and
brownout protection
•	 Thermally compensated charger
•	 AC lockout
•	 Temperature range: 20°C to 30°C
	 	
	
         (68°F to 86°F)
•	 UL 924 Listed

W

NE

Ordering Information

CVD	 1		 R	
Series

A	 BN		 -2C
Options

Operation
A	 -	 AC Only
E	 -	 Emergency

Faces
1	-	 Single
2	-	 Double

-DC	
-2C	

Letter Color

(Add

suffix to model)

Remote DC operation (1)	
2-circuit operation (1)

(1) 	For use with AC models only.

Housing
Finish
W	 -	 White
BN	 -	 Black with brushed face

R	-	 Red
G	-	 Green

Options

Accessories

(Order Separately)

121­­/2”

Options

(Add

suffix to model)

PMCW	
Pendant mounting kit (white)
PMCB	
121­­/2” Pendant mounting kit (black)
WGLX	
Wire guard (Wall mount)
WG-MLT	 Wire guard (Wall mount)
ccessories
(Order
WGLXC	
Wire guard (Ceiling
mount) Separately)
WGLXE	
Wire guard (End mount)

A

Dimensions
Power Consumption
9 1/8”
(23 cm)
10”

(25.5 cm)

11 3/4” (30 cm)
12 5/8” (32 cm)

1 5/8” (4.14 cm)

	
Red AC Only Models: 	
Green AC Only Models: 	
Red Emergency Models: 	
Green Emergency Models:  	

120VAC	
2.6 watts	
2.1 watts	
3.8 watts	
3.5 watts	

277VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts

*Wattage figures include LED lamps, transformer and electronics power
requirements. LED lamp assemblies (red or green) consume less than 1 watt.
Power factor, average: .8 (lagging)

73

CVER

Recessed Mount Edge-Lit LED Exit Sign
Features
AC Models
•	 Ceiling mounted models for
recessed installation
•	 Metal construction
•	 Available in two color finishes
•	 Clear acrylic plaque
•	 Red and green letter models
•	 Applique chevron arrows
•	 Long life LED lamps
•	 Bright, even letter illumination
•	 Energy-saving operation

W

NE

Ordering Information

	CVER 	 1		 R	

N	

•	 Easy to install
•	 120/277VAC, 60 Hz operation
Emergency Models
•	 Fully automatic charger
•	 Maintenance-free NiCad battery
•	 Low voltage disconnect
•	 Test switch and AC-On light
•	 Temperature range: 	20°C to 30°C       
	 	
(68°F to 86°F)
•	 ETL Listed

Availability To Be Announced

E		

	

Operation

Series

A	 -	 AC only
E	 -	 Emergency

CVER	 -  Recessed 	
	
	 mount
	
	

Faces
1	-	 Single
2	-	 Double*

* Provided standard with mirror
background.

Fully-adjustable universal mounting bar system
allows installations in standard construction
and suspended ceiling applications.

Trim/Housing
Finish

Letter Color

N	 -	 Satin aluminum
W	 -	 White

R	-	 Red
G	-	 Green

Options

(Add

suffix to model)

Accessories

(Order Separately)

Dimensions
D
E

F

Field installable chevrons provide for all possible
directional arrow requirements.

	 Power

Consumption

	
Red AC Only Models	
Green AC Only Models	
Red Emergency Models	
Green Emergency Models 	

120VAC	
2.2W	
2.5W	
3.3W	
3.6W	

277VAC
3.7W
4.4W
4.7W
5.2W

*	 Wattage figures include LED lamps, transformers and electronics 	
	 power requirements.

74

A

C

	

	

A	
7 7/8”	

B	
11”	

C	
12 5/8”	

D	
15”	

E	
14 3/8”	

F
4 1/8”

	 20.0 cm	 27.9 cm	 32.1 cm	 38.1 cm	 36.5 cm	 10.5 cm

B

Features

Ordering Information

Options

(Add

suffix to model)

Accessories

(Order Separately)

Remote Heads and Fixtures . ..........................................................76 to 78
Lamp Selector Guide .......................................................................................... 79
Voltage Drop Tables ................................................................................ 80
Unit Accessories . ................................................................................................. 81
National Electric Code ................................................................................. 82, 83
NFPA 101 Life Safety Code . ....................................................................... 84, 85
Limited Warranty ................................................................................................ 86

75

Remote Heads and Fixtures
Standard Remote
Lighting Heads

SRH Series

Injection molded thermoplastic lamphead/round mounting
plate assemblies. Mounts to 31/2” octagonal or single gang
boxes. For use with most commercial or industrial emergency fixtures. Standard finish is available in white or black.
Single and twin lamp fixtures with a choice of incandescent
or halogen PAR 36 lamps.
Lamp photometrics and IES files available on the web at www.dual-lite.com

	

White	

Black

Halogen PAR 36
Incandescent PAR 36
Sealed Beam	Sealed Beam	

	Single Head With	Twin Head With	Single Head With	Twin Head With	Lamp	Lamp	Lamp	
	Mounting Plate	
Mounting Plate	
Mounting Plate	
Mounting Plate	
Voltage	 Wattage	Part No.
	

SRHSW0605	

SRHDW0605	

SRHSB0605	

SRHDB0605	

6	

5.4	

0110258*

	

SRHSW0607	

SRHDW0607	

SRHSB0607	

SRHDB0607	

6	

7.2	

0110213*

	

SRHSW0618	

SRHDW0618	

SRHSB0618	

SRHDB0618	

6	

18	

0110127

	

SRHSW0625	

SRHDW0625	

SRHSB0625	

SRHDB0625	

6	

25	

0110041

	

SRHSW1207	

SRHDW1207	

SRHSB1207	

SRHDB1207	

12	

7.2	

0110289*

	

SRHSW1218	

SRHDW1218	

SRHSB1218	

SRHDB1218	

12	

18	

0110128

	

SRHSW1225	

SRHDW1225	

SRHSB1225	

SRHDB1225	

12	

25	

0110132

	

SRHSW1235	

SRHDW1235	

SRHSB1235	

SRHDB1235	

12	

35	

0110233

	

SRHSW2409	

SRHDW2409	

SRHSB2409	

SRHDB2409	

24	

9	

0110230*

	

SRHSW0608	

SRHDW0608	

SRHSB0608	

SRHDB0608	

6	

8	

0110162

	

SRHSW0612	

SRHDW0612	

SRHSB0612	

SRHDB0612	

6	

12	

0110159

	

SRHSW0620	

SRHDW0620	

SRHSB0620	

SRHDB0620	

6	

20	

0110157

	

SRHSW1208	

SRHDW1208	

SRHSB1208	

SRHDB1208	

12	

8	

0110189

	

SRHSW1212	

SRHDW1212	

SRHSB1212	

SRHDB1212	

12	

12	

0110190

* Sealed Beam type lamp

Outdoor Remote Lighting Heads
OMS Series
Outdoor aluminum spot with sealed lamp and swivel
assembly.  Furnished with round gasketed aluminum
mounting plate.  Mounts to 31⁄ 2” octagonal boxes.  
Lamp photometrics and IES files available on the web at www.dual-lite.com

	

White	

Black

Halogen PAR 36
Incandescent PAR 36
Sealed Beam	Sealed Beam	

	Single Head With	Twin Head With	Single Head With	Twin Head With	Lamp	Lamp	Lamp	
	Mounting Plate	

Mounting Plate	

Mounting Plate	

Mounting Plate	

	

OMSSW0605	

OMSDW0605	

OMSSB0605	

OMSDB0605	

6	

5.4	

0110258*

	

OMSSW0607	

OMSDW0607	

OMSSB0607	

OMSDB0607	

6	

7.2	

0110213*

	

OMSSW0618	

OMSDW0618	

OMSSB0618	

OMSDB0618	

6	

18	

0110127

	

OMSSW0625	

OMSDW0625	

OMSSB0625	

OMSDB0625	

6	

25	

0110041

	

OMSSW1207	

OMSDW1207	

OMSSB1207	

OMSDB1207	

12	

7.2	

0110289*

	

OMSSW1218	

OMSDW1218	

OMSSB1218	

OMSDB1218	

12	

18	

0110128

	

OMSSW1225	

OMSDW1225	

OMSSB1225	

OMSDB1225	

12	

25	

0110132

	

OMSSW1235	

OMSDW1235	

OMSSB1235	

OMSDB1235	

12	

35	

0110233

	

OMSSW0608	

OMSDW0608	

OMSSB0608	

OMSDB0608	

6	

8	

0110162

	

OMSSW0612	

OMSDW0612	

OMSSB0612	

OMSDB0612	

6	

12	

0110159

	

OMSSW0620	

OMSDW0620	

OMSSB0620	

OMSDB0620	

6	

20	

0110157

	

OMSSW1208	

OMSDW1208	

OMSSB1208	

OMSDB1208	

12	

8	

0110189

	

OMSSW1212	

OMSDW1212	

OMSSB1212	

OMSDB1212	

12	

12	

0110190

* Sealed Beam type lamp

76

Voltage	 Wattage	Part No.

All Metal Remote
Lighting Heads

Remote Heads and Fixtures

AHD

Stamped aluminum housing with metal
swivel. Standard finish available in white
or black.  Choice of incandescent or       
halogen PAR 36 lamps.  

Lamp photometrics and IES files available on the web at www.dual-lite.com

	

White	

Black

	Single Head With	Twin Head With	Single Head With	Twin Head With	Lamp	Lamp	Lamp	

Halogen PAR 36
Sealed Beam

Incandescent PAR 36
	Sealed Beam	

	Mounting Plate	

Mounting Plate	

Mounting Plate	

Mounting Plate	

Voltage	 Wattage	Part No.

	

AHDSW0605	

AHDDW0605	

AHDSB0605	

AHDDB0605	

6	

5.4	

0110258*

	

AHDSW0607	

AHDDW0607	

AHDSB0607	

AHDDB0607	

6	

7.2	

0110213*

	

AHDSW0618	

AHDDW0618	

AHDSB0618	

AHDDB0618	

6	

18	

0110127

	

AHDSW0625	

AHDDW0625	

AHDSB0625	

AHDDB0625	

6	

25	

0110041

	

AHDSW1207	

AHDDW1207	

AHDSB1207	

AHDDB1207	

12	

7.2	

0110289*

	

AHDSW1218	

AHDDW1218	

AHDSB1218	

AHDDB1218	

12	

18	

0110128

	

AHDSW1225	

AHDDW1225	

AHDSB1225	

AHDDB1225	

12	

25	

0110132

	

AHDSW1235	

AHDDW1235	

AHDSB1235	

AHDDB1235	

12	

35	

0110233

	

AHDSW2407	

AHDDW2407	

AHDSB2407	

AHDDB2407	

24	

7.2	

0110212*

	

AHDSW2413	

AHDDW2413	

AHDSB2413	

AHDDB2413	

24	

13	

0110009*

	

AHDSW2418	

AHDDW2418	

AHDSB2418	

AHDDB2418	

24	

18	

0110010*

	

AHDSW2428	

AHDDW2428	

AHDSB2428	

AHDDB2428	

24	

28	

0110011*

	

AHDSWLV30	

AHDDWLV30	

AHDSBLV30	

AHDDBLV30	

120	

30	

0110021*

	

AHDSW0608	

AHDDW0608	

AHDSB0608	

AHDDB0608	

6	

8	

0110162

	

AHDSW0612 (1)	

AHDDW0612 (1)	

AHDSB0612	

AHDDB0612	

6	

12	

0110159

	

AHDSW0620	

AHDDW0620	

AHDSB0620	

AHDDB0620	

6	

20	

0110157

	

AHDSW1208	

AHDDW1208	

AHDSB1208	

AHDDB1208	

12	

8	

0110189

AHDSB1212	

AHDDB1212	

12	

12	

0110190

	

(1)

AHDSW1212 	

(1)

AHDDW1212 	

* Sealed Beam type lamp
(1) Matches LM City of Chicago models.

Lamp photometrics and IES files available on the web at www.dual-lite.com

GNX Series
Moisture resistant thermoplastic head in black finish with
coated lamp terminals and
sealed swivel assembly.  Furnished with mounting plate.  
Available with a choice of
incandescent or halogen PAR
36 lamps.  Matches N4X series
units.

Available with shatter containment option.
Add “-L” to model number for Sealed Beam
Lamps PAR36 only. Example: GNXSB0625-L

	 N4X Remote Head Models	Lamp	Lamp	Lamp	
	Single	Twin	
Volts	 Watts	Part No.
	 GNXSB0605	

GNXDB0605	

6	

5.4	

0110258*

	 GNXSB0607	

GNXDB0607	

6	

7.2	

0110213*

	 GNXSB0618	

GNXDB0618	

6	

18	

0110127

	 GNXSB0625	

GNXDB0625	

6	

25	

0110041

	 GNXSB1209	

GNXDB1209	

12	

9	

0110202*

	 GNXSB1218	

GNXDB1218	

12	

18	

0110128

	 GNXSB1225	

GNXDB1225	

12	

25	

0110132

	 GNXSB1235	

GNXDB1235	

12	

35	

0110233

	 GNXSB0608	

GNXDB0608	

6	

8	

0110162

	 GNXSB0612	

GNXDB0612	

6	

12	

0110159

	 GNXSB0620	

GNXDB0620	

6	

20	

0110157

	 GNXSB1208	

GNXDB1208	

12	

8	

0110189

	 GNXSB1212	

GNXDB1212	

12	

12	

0110190

Halogen PAR 36 Incandescent PAR 36
Sealed Beam
	Sealed Beam	

Environmental
Lighting Head

* Sealed Beam Type lamp

77

Remote Heads and Fixtures
RERS
Injection molded housing. Surface mounted. Semi-recessed or
recessed mounting available with
kit. Black box, white trim.  Single
(RERS-1) and twin (RERS-2) lamp
models. Dimensions and mounting
kits same as Lite2.

Square

Catalog No.	

Recessed
Rectangle

Catalog No.	

Recessed
Eyeball

Lamp Part No.

124R-0628	
124R-1228	

0110003
0110007

Lamp Part No.

RERS-1-0609	
0110163
RERS-2-0607	
0110213
F-SRM	 Semi-recessed mounting kit
-FRM	

124R
Recessed mounted fixture with
frosted lens. White trim.  
Dimensions: 83⁄16” x 41⁄2” x 4”.

Gimbal

Fully-recessed option

133
Adjustable to 42° and rotated
through 358°. White standard,
other finishes upon request.
Dimensions: Trim ring: 47⁄ 8” dia.
Back box: 43⁄ 16” deep x 4” dia.
Catalog No.	

133-0618	
133-1218	

122
Adjustable (60° max.) recessed
mounted fixture. Matte white trim.
Dimensions: 81⁄ 2” dia. x 41⁄ 2”.
Incandescent PAR 36 Lamp Models
Catalog No.	

Lamp Part no.

122SB-0625	
122SB-1225	

0110041
0110132

Halogen PAR 36 Lamp Models
Catalog No	

Lamp Part No.

122SB-T-0608	
122SB-T-0612	
122SB-T-0620	
122SB-T-1208	
122SB-T-1212	

Lamp Part No.

0110002
0110006

0110162
0110159
0110157
0110189
0110190

Bayonet Base Lamp Models
Catalog No.	

Lamp Part No.

122-2407	
122-2413	
122-2418	
122-2428	

LZ Series Matching
Remote Lighting Heads

0110212
0110009
0110010
0110011

	 Single Remote	Single Remote	Lamp	Lamp	Lamp		

LZR

	 Head -White	

Architectural/commercial                   
design. High performance MR-16
halogen lamps standard.  Mounts to             
standard electrical boxes using
universal mounting plate provided.  
Fixture housing mounts to back plate
in a choice of four mounting
positions.  Housings secured using
locking screws provided.  

Head - Black	

Volts	 Watts	Part No.

	

LZRSW0605	

LZRSB0605	

6	

5	

0110256

	

LZRSW0610	

LZRSB0610	

6	

10	

0110261

	

LZRSW1205	

LZRSB1205	

12	

5	

0110263

	

LZRSW1210	

LZRSB1210	

12	

10	

0110264

	 Twin Remote	Twin Remote	Lamp	Lamp	Lamp		
	 Head -White	 Head - Black	 Volts	 Watts	Part No.
	

LZRDW0605	

LZRDB0605	

6	

5	

0110256

	

LZRDW0610	

LZRDB0610	

6	

10	

0110261

	

LZRDW1205	

LZRDB1205	

12	

5	

0110263

	

LZRDW1210	

LZRDB1210	

12	

10	

0110264

Lamp photometrics and IES files available on the web at www.dual-lite.com

IPS Series Matching
Remote Lighting Heads
C1D2R/C1D2TR
Suitable for wet and damp location
applications.  Rated for NEC Class I,
Division 2, Groups B, C and D as well 	
as Class I, Zone 2, Group IIB + H2  
environments. Black housing and
head assemblies.  Single (C1D2R)
and twin (C1D2TR) head models.

	
	
	
	
	
Model Numbers	
		Lamps	 *		Single Head		Twin Head
	 Volts		 Watts		 Hub Left Side(1)(2)	 	 Hub Left Side(1)(2)	
	 6	 	 8	
	 C1D2R-6V8W	 	 C1D2TR-6V8W
	 6	 	 12	 	 C1D2R-6V12W		 C1D2TR-6V12W
	 12	 	 8	
	 C1D2R-12V8W		 C1D2TR-12V8W
	 12	 	 12	 	 C1D2R-12V12W		 C1D2TR-12V12W

3R Listed

* PAR 36 Halogen sealed beam lamps.
(1)		Hub Right Side - add “R” to end of model number. Example C1D2R-6V8WR.
(2)	 	Hubs Both Sides - add “F” to end of model number. Example C1D2R-

Consult factory for additional voltage and wattage configurations for remote fixtures.

78

Lamp Selector Guide
		

MR16 Lamps

Dual-Lite	
Part Number	Lamp Number	Lamp Type	Lamp Volts	Lamp Watts
0110256	
MR16 6V5W	
Halogen	
6	
5
0110261	
MR16 6V10W	
Halogen	
6	
10
0110263	
MR16 12V5W	
Halogen	
12	
5
0110264	
MR16 12V10W	
Halogen	
12	
10

		

PAR 36 Sealed Beam Lamps

Dual-Lite	
Part Number	Lamp Number	Lamp Type	Lamp Volts	Lamp Watts
0110127	
4014  	
Incandescent	
6	
18
Incandescent	
6	
25
0110041	
4510  	
Incandescent	
12	
18
0110128	
4414  	
0110132	
4446	
Incandescent	
12	
25
0110233	
4411	
Incandescent	
12	
35
Halogen	
6	
8
0110162	
H7551  	
Halogen	
6	
12
0110159	
H7553  	
Halogen	
6	
20
0110157	
H7554  	
0110189	
H7555	
Halogen	
12	
8
0110190	
H7557	
Halogen	
12	
12

		

Double Contact Bayonet Base Lamps

Dual-Lite	
Part Number	Lamp Number	Lamp Type	Lamp Volts	Lamp Watts
0110212	
304	
Incandescent	
24	
7.2
0110009	
1692	
Incandescent	
24	
13
0110010	
308	
Incandescent	
24	
18
0110011	
310	
Incandescent	
24	
28
0110021	
30S11/93	
Incandescent	
125	
30

		

Wedge Base Lamps

Dual-Lite	
Part Number	Lamp Number	Lamp Type	Lamp Volts	Lamp Watts
0110258	
939	
Incandescent	
6	
5.4
0110213	
927	
Incandescent	
6	
7.2
KB-AN	
Incandescent	
12	
7.2
0110289	
915	
Incandescent	
12	
9
0110202	
0110230	
-	
Incandescent	
24	
9	

79

Voltage Drop Tables
The National Electrical Code limits voltage drop to a maximum of 5% of nominal. Circuit runs must be of sufficient     
capacity to maintain operating voltage when remote fixtures and/or exit signs are connected to the emergency lighting

TABLE A - Important Electrical Installation Information

	

		

12 Volt System		

6 Volt System

		
Wire Gauge		
Wire Gauge
	Total Watts	
#12	
#10	
#8	
#6	Total Watts	
#12	
#10	
#8	
	 on Wire Run		Max. Length of Wire Run (Feet)		
on Wire Run		Max. Length of Wire Run (Feet)

#6	

	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	

379
325
284
227
178
162
134
119
114
108
95
86
76
63
53
44
43
29
21
17
14
12
10
10
9

6	
7	
8	
10	
12	
14	
16	
18	
20	
21	
24	
25	
30	
35	
40	
48	
50	
75	
100	
125	
150	
175	
200	
225	
250	

378	
324	
283	
226	
178	
162	
133	
119	
113	
108	
89	
86	
75	
65	
53	
44	
43	
28	
21	
17	
14	
12	
10	
10	
9	

600	
515	
450	
360	
283	
257	
212	
189	
180	
171	
141	
136	
120	
103	
85	
70	
68	
45	
34	
27	
23	
19	
16	
16	
14	

955	
818	
716	
570	
450	
409	
338	
300	
286	
273	
225	
216	
190	
164	
135	
112	
108	
72	
54	
43	
36	
31	
27	
25	
22	

1518	
1301	
1138	
910	
715	
650	
538	
477	
455	
434	
357	
344	
303	
260	
214	
178	
172	
115	
86	
69	
57	
49	
42	
40	
36	

6	
7	
8	
10	
12	
14	
16	
18	
20	
21	
24	
25	
30	
35	
40	
48	
50	
75	
100	
125	
150	
175	
200	
225	
250	

94	
81	
70	
56	
44	
40	
33	
30	
28	
27	
24	
21	
19	
15	
13	
11	
11	
7	
5	
4	
3	
3	
2	
2	
2	

150	
129	
112	
90	
70	
64	
53	
47	
45	
43	
38	
34	
30	
25	
21	
17	
17	
11	
8	
7	
5	
5	
4	
4	
3	

238	
204	
179	
143	
112	
102	
84	
75	
71	
68	
60	
54	
48	
39	
33	
28	
27	
18	
14	
11	
9	
8	
6	
6	
5	

Values not shown in Table A may be calculated using the following formulas:
	 Length (Feet) =
I. Maximum
Example: 	
	

Table B Constant Value
	
Maximum Load (Watts)
Find the maximum circuit length for #8 wire on a 24 volt system with an 80 watt load.
Maximum Length (Feet) = 21613 ÷ 80 = 270 feet.

Table B Constant Value
II. Maximum Load (Watts) = 	
	
Maximum Length (Feet)
Example:	
Find the maximum circuit load for 540 feet of #12 wire on a 32 volt system.
	
Maximum Load (Watts) = 15197 ÷ 540 = 28 watts.

Table B

Constant Values per Voltage System Wire Size (Maximum Voltage Drop 5%)
System
Wire Size	

		
#12	

Constant 	

534	

System	
Wire Size	

#12	

Constant	

6 Volt
#10	
#8	
849	

#10	

#6	

350	

					
#12	
#10	
#8	

2148	

32 Volt	
#8	
#6	

2137	

#4	

#12	

3397	

#10	

5403	
48 Volt	
#8	

#6	

12 Volt
#4	

8590	

#6	

13660	

#4	

#12	

					
#12	
#10	
#8	
8548	

#10	

13588	

#6	

21613	

110 Volt
#8	
#6	

24 Volt
#4

34363	

54641

#4	

#2

15197	 24157	 38423	 61090	 97140	 34193	 54353	 86452	 137454	 218565	 179575	 285450	 454025	 721875	 1147850	 1824900

Uniform Loads
The maximum circuit length data in Table A (and derived from Table B) assumes that 100% of the load is concentrated at the end of the run. If
equally sized loads can be equally spaced along the run, maximum circuit length can be increased by the multipliers shown in Table C.

Table C

Multipliers for Equally Sized, Equally Spaced Loads (Maximum Voltage Drop 5%)
Number of Fixtures
Multiply Distance By	

80

	

2	

3	

4	

5	

6	

7	

8	

9	

10	

n

1.333	

1.500	

1.600	

1.670	

1.714	

1.750	

1.777	

1.800	

1.818	

2n/(n+1)

Unit	Accessories
Wire Guards

Mounting Brackets and Shelves

Offered	for	most	Dual-Lite	emergency	lights	and	exits.	
Constructed	of	heavy	gauge	steel,	all	wire	guards	are	
standard	with	chrome	plating.	Order	as	separate	line	item.

For	mounting	of	AS	Series	industrial	emergency	lighting	
units.

WB-6

6000

L-6 & L-12-S
mounting BrACkets And sHelVes

Wire guArds
CAt. no.
	 WGLZ	
	 S6WG	
	 WGEL	
	 	
	 40G
	 	
	 	
	 	
	 41G	
	 	
	 	
	 WGLX
	 	
WGLXC
	 	
WGLXE
	 	
WGTW
	 	
WGTCE
	 	
	 	
WG-MLT
	 	

CAt. no.
WB-6	
6000	
L-6	
L-12-S

for use WitH
All	enclosure	1	&	2	models	
Enclosure	1	models	only	
Enclosure	1	models	only	
Enclosure	2	models	only	

type
Bracket	
Shelf	
Shelf	
Shelf	

dimensions
-11”	H	x	14”	L	x	81⁄8”	D
11”	H	x	14”	L	x	81⁄8”	D
11”	H	x	16”	L	x	81⁄8”	D

for use WitH
LZ	Series	(except	High-Capacity	models)	
Remote	heads	
EZ-2,	EZ-2R	and	LZ	High-Capacity	Series,	
Remote	heads,	CV	Series

dimensions (inside)
61⁄4”	H	x	14”	L	x	41⁄4”	D
8”	H	x	8”	L	x	8”	D
8”	H	x	20”	L	x	8”	D

LM	Series	with	top	mounted	heads,		
AS	Series	(enclosure	1	models),	N4X	Series,
CVEC	Series	(15	and	30	watt	models)	and	
NYXC	tandem	units

181⁄2”	H	x	20”	L	x	12”	D

AS	Series	(enclosure	2	models),	
Delite	Cylinder	Series,	SMC	exits	and
CVEC	Series	(50	and	100	watt	models)
EXT-122-EM-K,	Wall	mount	LX,	LED	and		
Sempra	Series	exits,	Wall	Mount	CV3	Series
Ceiling	mount	LX,	LED,	Sempra		and	
CV3	Series	exits	

21”	H	x	23”	L	x	15”	D

Vandal Resistant Shields

10”	H	x	14”	L	x	21⁄4”	D

For	protection	against	vandalism	or	accidental	damage.	
Prevents	tampering	with	mountings	and	lamps.	

End	mount	LX,	LED	and	Sempra,	CV3	and		
CVD	Series	exits
Wall	mount	LT,		Freedom	LED,	CVT		
NYDC	and	NYX	Series	exits

101⁄ 2”	H	x	141⁄ 2”	L	x	31⁄ 2”	D

Ceiling	or	end	mount	LT,	CVD,	CVT			
and	Freedom	LED	Series	exits.		Ceiling
mount	NYDC	and	NYX	Series	exits	
Lite2	Series,	Wall	mount	LX,	DK,	Sempra	
DEX,	CV3	and	CVD	Series	exits	

20”	H	x	167⁄ 8”	L	x	8”	D

101⁄4”	H	x	133⁄4”	L	x	31⁄ 2”	D

16”	H	x	20”	L	x	77⁄ 8”	D

115⁄ 8”	H	x	135⁄ 8”	L	x	7”	D

VRS/VRS-4X
VRS2

VRS3

VAndAl sHields
CAt. no.
for use WitH
VRS	
EZ-2,	LZ,	LZ	High	Capacity,	EXT-122-EM-K,			
	 VRS-4X*	
EZ-2R	Series	and	CV	Series	
VRS2	
Lite2	Series,	LT	Series	exits		
	 VRS3	
LX,	DK,	Sempra	and	CV3	Series	exits		
		
* VRS-4X supplied with a neoprene wall gasket

dimensions (outside)
20”	L		x	101⁄ 2”	H		x	7 3⁄ 4”	D
211⁄ 4”	L		x	19 3⁄ 4”	H		x	6 1⁄ 4”	D
15 1⁄ 2”	L		x	111⁄ 2”	H		x	4 1⁄ 2”	D

81

National Electric Code
NEC (NFPA 70) - 2005
I. General
700.1 Scope. The provisions of this article apply to the electrical safety of the
installation, operation, and maintenance of emergency systems consisting of
circuits and equipment intended to supply, distribute, and control electricity for
illumination, power, or both, to required facilities when the normal electrical
supply or system is interrupted. Emergency systems are those systems legally
required and classed as emergency by municipal, state, federal, or other codes,
or by any governmental agency having jurisdiction. These systems are intended
to automatically supply illumination, power, or both, to designated areas and
equipment in the event of failure of the normal supply or in the event of accident
to elements of a system intended to supply, distribute, and control power and
illumination essential for safety to human life.
FPN No. 1: For further information regarding wiring and installation of
emergency systems in health care facilities, see Article 517.
FPN No. 2: For further information regarding performance and maintenance
of emergency systems in health care facilities, see NFPA 99-2002, Standard for
Health Care Facilities.
FPN No. 3: Emergency systems are generally installed in places of assembly
where artificial illumination is required for safe exiting and for panic control
in buildings subject to occupancy by large numbers of persons, such as
hotels, theaters, sports arenas, health care facilities, and similar institutions.
Emergency systems may also provide power for such functions as ventilation
where essential to maintain life, fire detection and alarm systems, elevators,
fire pumps, public safety communications systems, industrial processes where
current interruption would produce serious life safety or health hazards, and
similar functions.
FPN No. 4: For specification of locations where emergency lighting is considered
essential to life safety, see  NFPA 101®-2003, Life Safety Code®.
FPN No. 5: For further information regarding performance of emergency and
standby power systems, see NFPA 110®- 2002, Standard for Emergency and
Standby Power Systems.
700.2 Application of Other Articles. Except as modified by this article, all
applicable articles of this Code shall apply.

700.3 Equipment Approval. All equipment shall be approved for use on

emergency systems.

700.4 Tests and Maintenance.
(A) Conduct or Witness Test. The authority having jurisdiction shall conduct or

witness a test of the complete system upon installation and periodically afterward.
(B) Tested Periodically. Systems shall be tested periodically on a schedule
acceptable to the authority having jurisdiction to ensure the systems are
maintained in proper operating condition.
(C) Battery Systems Maintenance. Where battery systems or unit equipments
are involved, including batteries used for starting, control, or ignition in auxiliary
engines, the authority having jurisdiction shall require periodic maintenance.
(D) Written Record. A written record shall be kept of such tests and maintenance.
(E) Testing Under Load. Means for testing all emergency lighting and power
systems during maximum anticipated load conditions shall be provided.
FPN: For testing and maintenance procedures of emergency power supply
systems (EPSSs), see NFPA 110-2002, Standard for Emergency and Standby Power
Systems.

700.5 Capacity.
(A) Capacity and Rating. An emergency system shall have adequate capacity

and rating for all loads to be operated simultaneously. The emergency system
equipment shall be suitable for the maximum available fault current at its
terminals.
(B) Selective Load Pickup, Load Shedding, and Peak Load Shaving. The
alternate power source shall be permitted to supply emergency, legally required
standby, and optional standby system loads where the source has adequate
capacity or where automatic selective load pickup and load shedding is provided as
needed to ensure adequate power to
(1) the emergency circuits, (2) the legally required standby circuits, and (3) the
optional standby circuits, in that order of priority. The alternate power source shall
be permitted to be used for peak load shaving, provided these conditions are met.    
Peak load-shaving operation shall be permitted for satisfying the test requirement
of 700.4(B), provided all other conditions of 700.4 are met.  A portable or
temporary alternate source shall be available whenever the emergency generator
is out of service for major maintenance or repair.

700.6 Transfer Equipment.
(A) General. Transfer equipment, including automatic transfer switches, shall be

automatic, identified for emergency use, and approved by the authority having
jurisdiction. Transfer equipment shall be designed and installed to prevent the
inadvertent interconnection of normal and emergency sources of supply in any
operation of the transfer equipment. Transfer equipment and electric power
production systems installed to permit operation in parallel with the normal source
shall meet the requirements of Article 705.
(B) Bypass Isolation Switches. Means shall be permitted to bypass and isolate the
transfer equipment. Where bypass isolation switches are used, inadvertent parallel
operation shall be avoided.
(C) Automatic Transfer Switches. Automatic transfer switches shall be electrically
operated and mechanically held.
(D) Use. Transfer equipment shall supply only emergency loads.
700.7 Signals. Audible and visual signal devices shall be provided, where
practicable, for the purpose described in 700.7(A) through 700.7(D).
(A) Derangement. To indicate derangement of the emergency source.
(B) Carrying Load. To indicate that the battery is carrying load.
(C) Not Functioning. To indicate that the battery charger is not functioning.
(D) Ground Fault. To indicate a ground fault in solidly grounded wye emergency

82

systems of more than 150 volts to ground and circuit-protective devices rated 1000
amperes or more. The sensor for the ground-fault signal dewwwvices shall be
located at, or ahead of, the main system disconnecting means for the emergency
source, and the maximum setting of the signal devices shall be for a ground-fault
current of 1200 amperes. Instructions on the course of action to be taken in event
of indicated ground fault shall be located at or near the sensor location.
FPN: For signals for generator sets, see NFPA 110-2002,Standard for Emergency
and Standby Power Systems.

700.8 Signs.
(A) Emergency Sources. A sign shall be placed at the service entrance
equipment, indicating type and location of on-site emergency power sources.

Exception: A sign shall not be required for individual unit equipment as specified
in 700.12(F).

(B) Grounding. Where the grounded circuit conductor connected to the

emergency source is connected to a grounding electrode conductor at a location
remote from the emergency source, there shall be a sign at the grounding location
that shall identify all emergency and normal sources connected at that location.

II. Circuit Wiring
700.9 Wiring, Emergency System.
(A) Identification. All boxes and enclosures (including transfer switches,

generators, and power panels) for emergency circuits shall be permanently marked
so they will be readily identified as a component of an emergency circuit or system.
(B) Wiring. Wiring of two or more emergency circuits supplied from the same
source shall be permitted in the same raceway, cable, box, or cabinet. Wiring from
an emergency source or emergency source distribution overcurrent protection
to emergency loads shall be kept entirely independent of all other wiring and
equipment, unless otherwise permitted in (1) through (4):
(1) Wiring from the normal power source located in transfer equipment enclosures
(2) Wiring supplied from two sources in exit or emergency luminaires (lighting
fixtures)
(3) Wiring from two sources in a common junction box, attached to exit or
emergency luminaires (lighting fixtures)
(4) Wiring within a common junction box attached to unit equipment, containing
only the branch circuit supplying the unit equipment and the emergency circuit
supplied by the unit equipment
(C) Wiring Design and Location. Emergency wiring circuits shall be designed and
located so as to minimize the hazards that might cause failure due to flooding,
fire, icing, vandalism, and other adverse conditions.
(D) Fire Protection. Emergency systems shall meet the additional requirements
in 700.9(D)(l) and (D)(2) assembly occupancies for not less than 1000 persons or
in buildings above 23 m (75 ft) in height with any of the following occupancy
classes: assembly, educational, residential, detention and correctional, business,
and mercantile.

(1) Feeder-Circuit Wiring. Feeder-circuit wiring shall meet one of the
following conditions:

(1) Be installed in spaces or areas that are fully protected by an approved
automatic fire suppression system
(2) Be a listed electrical circuit protective system with a minimum l-hour fire rating
(3) Be protected by a listed thermal barrier system for electrical system components
(4) Be protected by a fire-rated assembly listed to achieve a minimum fire rating
of 1 hour
(5) Be embedded in not less than 50 mm (2 in.) of concrete
(6) Be a cable listed to maintain circuit integrity for not less than 1 hour when
installed in accordance with the listing requirements
(2) Feeder-Circuit Equipment. Equipment for feeder circuits (including transfer
switches, transformers, and panel boards) shall be located either in spaces fully
protected by approved automatic fire suppression systems (including sprinklers,
carbon dioxide systems) or in spaces with a 1-hour fire resistance rating.
FPN: For the definition of occupancy classification, see Section 6.1 of NFPA 1012003, Life Safety Code.

III. Sources of Power

700.12 General Requirements. Current supply shall be such that, in the event
of failure of the normal supply to, or within, the building or group of buildings
concerned, emergency lighting, emergency power, or both shall be available
within the time required for the application but not to exceed 10 seconds. The
supply system for emergency purposes, in addition to the normal services to
the building and meeting the general requirements of this section, shall be one
or more of the types of systems described in 700.12(A) through 700.12(E). Unit
equipment in accordance with 700.12(F) shall satisfy the applicable requirements
of this article.    In selecting an emergency source of power, consideration shall
be given to the occupancy and the type of service to be rendered, whether of
minimum duration, as for evacuation of a theater, or longer duration, as for
supplying emergency power and lighting due to an indefinite period of current
failure from trouble either inside or outside the building.    Equipment shall be
designed and located so as to minimize the hazards that might cause complete
failure due to flooding, fires, icing, and vandalism.    Equipment for sources of
power as described in 700.12(A) through 700.12(E) where located within assembly
occupancies for greater than 1000 persons or in buildings above 23 m (75 ft) in
height with any of the following occupancy classes — assembly, educational,
residential, detention and correctional, business, and mercantile — shall be
installed either in spaces fully protected by approved automatic fire suppression
systems (sprinklers, carbon dioxide systems, and so forth) or in spaces with a 1-hour
fire rating.

National Electric Code
NEC (NFPA 70) - 2005

FPN No. 1: For the definition of occupancy classification, see Section 6.1 of NFPA
101-2003, Life Safety Code.
FPN No. 2: Assignment of degree of reliability of the recognized emergency
supply system depends on the careful evaluation of the variables at each
particular installation.
(A) Storage Battery. Storage batteries used as a source of power for emergency
systems shall be of suitable rating and capacity to supply and maintain the total
load for a minimum period of 1 1/2 hours, without the voltage applied to the load
falling below 87-1/2 percent of normal.  Batteries, whether of the acid or alkali
type, shall be designed and constructed to meet the requirements of emergency
service and shall be compatible with the charger for that particular installation.    
For a sealed battery, the container shall not be required to be transparent.
However, for the lead acid battery that requires water additions, transparent or
translucent jars shall be furnished. Automotive-type batteries shall not be used.  
An automatic battery charging means shall be provided.

(B) Generator Set.
(1) Prime Mover-Driven. For a generator set driven by a prime mover acceptable

to the authority having jurisdiction and sized in accordance with 700.5, means shall
be provided for automatically starting the prime mover on failure of the normal
service and for automatic transfer and operation of all required electrical circuits.
A time-delay feature permitting a 15-minute setting shall be provided to avoid
retransfer in case of short-time reestablishment of the normal source.
(2) Internal Combustion as Prime Movers. Where internal combustion engines
are used as the prime mover, an on-site fuel supply shall be provided with an onpremise fuel supply sufficient for not less than 2 hours’ full-demand operation of
the system. Where power is needed for the operation of the fuel transfer pumps
to deliver fuel to a generator set day tank, this pump shall be connected to the
emergency power system.
(3) Dual Supplies. Prime movers shall not be solely dependent on a public utility
gas system for their fuel supply or municipal water supply for their cooling systems.
Means shall be provided for automatically transferring from one fuel supply to
another where dual fuel supplies are used.
Exception: Where acceptable to the authority having jurisdiction, the use of
other than on-site fuels shall be permitted where there is a low probability of a
simultaneous failure of both the off-site fuel delivery system and power from the
outside electrical utility company.
(4) Battery Power and Dampers. Where a storage battery is used for control
or signal power or as the means of starting the prime mover, it shall be suitable
for the purpose and shall be equipped with an automatic charging means
independent of the generator set. Where the battery charger is required for the
operation of the generator set, it shall be connected to the emergency system.
Where power is required for the operation of dampers used to ventilate the
generator set, the dampers shall be connected to the emergency system.
(5) Auxiliary Power Supply. Generator sets that require more than 10 seconds
to develop power shall be permitted if an auxiliary power supply energizes the
emergency system until the generator can pick up the load.
(6) Outdoor Generator Sets. Where an outdoor housed generator set is equipped
with a readily accessible disconnecting means located within sight of the building
or structure supplied, an additional disconnecting means shall not be required
where ungrounded conductors serve or pass through the building or structure.
(C) Uninterruptible Power Supplies. Uninterruptible power supplies used to
provide power for emergency systems shall comply with the applicable provisions
of 700.12(A) and 700. 12(B)
(D) Separate Service. Where acceptable to the authority having jurisdiction as
suitable for use as an emergency source of power, an additional service shall be
permitted. This service shall be in accordance with the applicable provisions of
Article 230 and the following additional requirements:
(1) Separate service drop or service lateral
(2) Service conductors sufficiently remote electrically and physically from any other
service conductors to minimize the possibility of simultaneous interruption          
of supply
(E) Fuel Cell System. Fuel cell systems used as a source of power for emergency
systems shall be of suitable rating and capacity to supply and maintain the total
load for not less than 2 hours of full-demand operation.    Installation of a fuel cell
system shall meet the requirements of Parts II through VIII of Article 692.    Where
a single fuel cell system serves as the normal supply for the building or group
of buildings concerned, it shall not serve as the sole source of power for the
emergency standby system.
(F) Unit Equipment. Individual unit equipment for emergency illumination shall
consist of the following:
(1) A rechargeable battery
(2) A battery charging means
(3)	Provisions for one or more lamps mounted on the equipment, or shall be
permitted to have terminals for remote lamps, or both
(4) A relaying device arranged to energize the lamps automatically upon failure of
the supply to the unit equipment
The batteries shall be of suitable rating and capacity to supply and maintain at
not less than 87-1/2 percent of the nominal battery voltage for the total lamp load
associated with the unit for a period of at least l l/2 hours, or the unit equipment
shall supply and maintain not less than 60 per cent of the initial emergency
illumination for a period of at least 11/2 hours. Storage batteries, whether of the
acid or alkali type, shall be designed and constructed to meet the requirements of
emergency service.    Unit equipment shall be permanently fixed in place (i.e., not
portable) and shall have all wiring to each unit installed in accordance with the
requirements of any of the wiring methods in Chapter 3. Flexible cord-and-plug
connection shall be permitted, provided that the cord does not exceed 900 mm
(3 ft) in length. The branch circuit feeding the unit equipment shall be the same
branch circuit as that serving the normal lighting in the area and connected ahead
of any local switches. The branch circuit that feeds unit equipment shall be clearly
identified at the distribution panel. Emergency luminaires (illumination fixtures)
that obtain power from a unit equipment and are not part of the unit equipment

shall be wired to the unit equipment as required by 700.9 and by one of the wiring
methods of Chapter 3.
Exception: In a separate and uninterrupted area supplied by a minimum of three
normal lighting circuits, a separate branch circuit for unit equipment shall be
permitted if it originates from the same panelboard as that of the normal lighting
circuits and is provided with a lock-on feature.

IV. Emergency System Circuits for Lighting
and Power
700.15 Loads on Emergency Branch Circuits. No appliances and no lamps, other

than those specified as required for emergency use, shall be supplied by emergency
lighting circuits.

700.16 Emergency Illumination. Emergency illumination shall include all required
means of egress lighting, illuminated exit signs, and all other lights specified as
necessary to provide required illumination.  Emergency lighting systems shall be
designed and installed so that the failure of any individual lighting element, such
as the burning out of a light bulb, cannot leave in total darkness any space that
requires emergency illumination.    Where high-intensity discharge lighting such as
high and low-pressure sodium, mercury vapor, and metal halide is used as the sole
source of normal illumination, the emergency lighting system shall be required to
operate until normal illumination has been restored.
Exception: Alternative means that ensure emergency lighting illumination level is
maintained shall be permitted.
700.17 Circuits for Emergency Lighting. Branch circuits that supply emergency

lighting shall be installed to provide service from a source complying with 700.12
when the normal supply for lighting is interrupted. Such installations shall provide
either of the following:
(l) An emergency lighting supply, independent of the general lighting supply, with
provisions for automatically transferring the emergency lights upon the event of
failure of the general lighting system supply
(2) Two or more separate and complete systems with independent power supply,
each system providing sufficient current for emergency lighting purposes unless
both systems are used for regular lighting purposes and are both kept lighted,
means shall be provided for automatically energizing either system upon failure
of the other. Either or both systems shall be permitted to be a part of the general
lighting system of the protected occupancy if circuits supplying lights for emergency
illumination are installed in accordance with other sections of this article.

700.18 Circuits for Emergency Power. For branch circuits that supply equipment
classed as emergency, there shall be an emergency supply source to which the load
will be transferred automatically upon the failure of the normal supply.

V. Control—Emergency Lighting Circuits
700.20 Switch Requirements. The switch or switches installed in emergency

lighting circuits shall be arranged so that only authorized persons have control of
emergency lighting.
Exception No. 1: Where two or more single-throw switches are connected in parallel
to control a single circuit, at least one of these switches shall be accessible only to
authorized persons.
Exception No. 2: Additional switches that act only to put emergency lights into
operation but not disconnect them shall be permissible.
Switches connected in series or 3- and 4-way switches shall not be used.

700.21 Switch Location. All manual switches for controlling emergency circuits
shall be in locations convenient to authorized persons responsible for their
actuation. In facilities covered by Articles 518 and 520, a switch for controlling
emergency lighting systems shall be located in the lobby or at a place conveniently
accessible thereto.     In no case shall a control switch for emergency lighting to be
placed in a motion-picture projection booth or on a stage or platform.
Exception: Where multiple switches are provided, one such switch shall be permitted
in such locations where arranged so that it can only energize the circuit, but cannot
de-energize the circuit.
700.22 Exterior Lights. Those lights on the exterior of a building that are not

required for illumination when there is sufficient daylight shall be permitted to be
controlled by an automatic light-actuated device.

VI. Overcurrent Protection

700.25 Accessibility. The branch-circuit overcurrent devices in emergency circuits
shall be accessible to authorized persons only.

700.26 Ground-Fault Protection of Equipment. The alternate source for

emergency systems shall not be required to have ground-fault protection of
equipment with automatic disconnecting means. Ground-fault indication of the
emergency source shall be provided per 700.7(D).

700.27 Coordination. Emergency system(s) overcurrent devices shall be selectively
coordinated with all supply side overcurrent protective devices.

83

National
Fire
Protection
Assn.
LIFE SAFETY CODE
(NFPA 101) - 2003
Section 4.6 General Requirements
4.6.13 Maintenance and Testing.

4.6.13.1 Whenever or wherever any device, equipment, system, condition,
arrangement, level of protection, or any other feature is required for compliance
with the provisions of this Code, such device, equipment, system, condition,
arrangement, level of protection, or other feature shall thereafter be continuously
maintained in accordance with applicable NFPA requirements or as directed by the
authority having jurisdiction.
4.6.13.2* Existing life safety features obvious to the public, if not required by the
Code, shall be either maintained or removed.
4.6.13.3 Equipment requiring periodic testing or operation to ensure its
maintenance shall be tested or operated as specified elsewhere in this Code or as
directed by the authority having jurisdiction.
4.6.13.4 Maintenance and testing shall be performed under the supervision of a
responsible person who shall ensure that testing and maintenance are made at
specified intervals in accordance with applicable NFPA standards or as directed by
the authority having jurisdiction.

7.8 Illumination of Means of Egress.
7.8.1 General
7.8.1.1* Illumination of means of egress shall be provided in accordance with
Section 7.8 for every building and structure where required in Chapter 11 through
Chapter 42. For the purposes of this requirement, exit access shall include only
designated stairs, aisles, corridors, ramps, escalators, and passageways leading
to an exit. For the purposes of this requirement, exit discharge shall include only
designated stairs, aisles, corridors, ramps, escalators, walkways, and exit passage
ways leading to a public way.
7.8.1.2 Illumination of means of egress shall be continuous during the time that the
conditions of occupancy require that the means of egress be available for use, unless
otherwise provided in 7.8.1.2.2.
7.8.1.2.1 Artificial lighting shall be employed at such locations and for such periods
of time as are necessary to maintain the illumination to the minimum criteria values
herein specified.
7.8.1.2.2 Automatic, motion sensor-type lighting switches shall be permitted within
the means of egress, provided that the switch controllers are equipped for fail-safe
operation, the illumination timers are set for a minimum 15-minute duration, and
the motion sensor is activated by any occupant movement in the area served by the
lighting units.
7.8.1.3* The floors and other walking surfaces within an exit and within the
portions of the exit access and exit discharge designated in 7.8.1.1 shall be
illuminated as follows:
(1) 	 During conditions of stair use, the minimum illumination for new stairs shall be
at least 108 lux (10 ft-candle), measured at the walking surfaces.
(2) 	 The minimum illumination for floors and walking surfaces, other than new
stairs, shall be to values of at least 10.8 lux (1 ft-candle), measured at the floor.
(3) 	 In assembly occupancies, the illumination of the floors of exit access shall be
at least 2.2 lux (0.2 ft-candle) during periods of performances or projections
involving directed light.
(4) 	 * The minimum illumination requirements shall not apply where operations or
processes require low lighting levels.
7.8.1.4* Required illumination shall be arranged so that the failure of any single
lighting unit does not result in an illumination level of less than 2.2 lux (0.2 ftcandle) in any designated area.
7.8.1.5 The equipment or units installed to meet the requirements of Section 7.10
also shall be permitted to serve the function of illumination of means of egress,
provided that all requirements of Section 7.8 for such illumination are met.

7.8.2 Sources of Illumination.
7.8.2.1* Illumination of means of egress shall be from a source considered reliable
by the authority having jurisdiction.
7.8.2.2 Battery-operated electric lights and other types of portable lamps or lanterns
shall not be used for primary illumination of means of egress. Battery-operated
electric lights shall be permitted to be used as an emergency source to the extent
permitted under Section 7.9.

7.9.2 Performance of System.

7.9.2.1* Emergency illumination shall be provided for not less than 1 1/2 hours
in the event of failure of normal lighting. Emergency lighting facilities shall be
arranged to provide initial illumination that is not less than an average of 10.8 lux
(1 ft-candle) and, at any point, not less than 1.1 lux (0.1 ft-candle), measured along
the path of egress at floor level. Illumination levels shall be permitted to decline to
not less than an average of 6.5 lux (0.6 ft candle) and, at any point, not less than
6.5 lux (0.06 ft-candle) at the end of the 1 1/2 hours. A maximum-to-minimum
illumination uniformity ratio of 40 to 1 shall not be exceeded.
7.9.2.2* The emergency lighting system shall be arranged to provide the required
illumination automatically in the event of any interruption of normal lighting due
to any of the following:
(1) 	 Failure of a public utility or other outside electrical power supply
(2) 	 Opening of a circuit breaker or fuse
(3) 	 Manual act(s), including accidental opening of a switch controlling normal
lighting facilities
7.9.2.3 Emergency generators providing power to emergency lighting systems shall
be installed, tested, and maintained in accordance with NFPA 110,
Standard for Emergency and Standby Power Systems. Stored electrical energy
systems, where required in this Code, shall be installed and tested in accordance
with NFPA 111, Standard on Stored Electrical Energy Emergency and Standby
Power Systems.
7.9.2.4* Battery-operated emergency lights shall use only reliable types of
rechargeable batteries provided with suitable facilities for maintaining them in
properly charged condition.
Batteries used in such lights or units shall be approved for their intended use and
shall comply with NFPA 70, National Electrical Code®.
7.9.2.5  The emergency lighting system shall be either continuously in operation or
shall be capable of repeated automatic operation without manual intervention.

7.9.3 Periodic Testing of Emergency Lighting Equipment.

7.9.3.1  Required emergency lighting systems shall be tested  in accordance with
one of the three options offered by 7.9.3.1.1, 7.9.3.1.2, or 7.9.3.1.3.
7.9.3.1.1   Testing of required emergency lighting systems | shall be permitted to
be conducted as follows:
(1) 	 Functional testing shall be conducted at 30-day intervals for not less than 30
seconds.
(2) 	 Functional testing shall be conducted annually for not less than 1 1/2 hours if
the emergency lighting system is battery powered.
(3) 	 The emergency lighting equipment shall be fully operational for the duration
of the tests required by 7.9.3.1.1 ( 1 ) and 7.9.3.1.1 (2).  
(4) 	 Written records of visual inspections and tests shall be kept by the owner for
inspection by the authority having jurisdiction.
7.9.3.1.2   Testing of required emergency lighting systems shall be permitted to be
conducted as follows:
(1) 	 Self-testing/self-diagnostic battery-operated emergency lighting equipment
shall be provided.
(2) 	 Self-testing/self-diagnostic battery-operated emergency lighting equipment
shall automatically perform not less than once every 30 days a test for not less
than 30 seconds and a diagnostic routine.
(3) 	 Self-testing/self-diagnostic battery-operated emergency lighting equipment
shall indicate failures by a status indicator.
(4) 	 A visual inspection shall be performed at intervals not exceeding 30 days.
(5) 	 Functional testing shall be conducted annually for not less than 1 1/2 hours.
(6) 	 Self-testing/self-diagnostic battery-operated emergency lighting equipment
shall be fully operational for the duration of the 1 1/2 hour test.
(7) 	 Written records of visual inspections and tests shall be kept by the owner for
inspection by the authority having jurisdiction.
7.9.3.1.3   Testing of required emergency lighting systems shall be permitted to be
conducted as follows:
(1) 	 Computer-based, self-testing/self-diagnostic battery-operated emergency
lighting equipment shall be provided.
(2) 	 The emergency lighting equipment shall automatically perform not less than
once every 30 days a test for not less than 30 seconds and a diagnostic routine.
(3) 	 The emergency lighting equipment shall automatically perform annually a test
for not less than 11/2 hours.
(4) 	 The emergency lighting equipment shall be fully operational for the duration
of the tests required by 7.9.3.1.3(2) and 7.9.3.1.3(3).
(5)	 The computer-based system shall be capable of providing a report of the
history of tests and failures at all times.

7.9 Emergency Lighting.
7.9. 1 General.

7.9.1.1* Emergency lighting facilities for means of egress shall be provided in
accordance with Section 7.9 for the following:
(1) 	 Buildings or structures where required in Chapter 11 through Chapter 42
(2) 	 Underground and limited access structures as addressed in Section 11.7
(3) 	 High-rise buildings as required by other sections of this Code
(4) 	 Doors equipped with delayed-egress locks
(5) 	 Stair shaft and vestibule of smokeproof enclosures, for which the following also
apply:
	
(a) 	 The stair shaft and vestibule shall be permitted to include a standby
generator that is installed for the smokeproof enclosure mechanical
ventilation equipment.     
	
(b) 	The standby generator shall be permitted to be used for the stair shaft
and vestibule emergency lighting power supply.
7.9.1.2 For the purposes of 7.9.1.1, exit access shall include only designated stairs,
aisles, corridors, ramps, escalators, and passageways leading to an exit. For the
purposes of 7.9.1.1, exit discharge shall include only designated stairs, ramps, aisles,
walkways, and escalators leading to a public way.
7.9.1.3 Where maintenance of illumination depends on changing from one energy
source to another, a delay of not more than 10 seconds shall be permitted.

84

7.10 Marking of Means of Egress.
7.10.1 General.

7.10.1.1 Where Required. Means of egress shall be marked in accordance with
Section 7.10 where required in Chapter 11 through Chapter 42.
7.10.1.2* Exits. Exits, other than main exterior exit doors that obviously and clearly
are identifiable as exits, shall be marked by an approved sign that is readily visible
from any direction of exit access.
7.10.1.3 Exit Stair Door Tactile Signage. Tactile signage shall be provided to meet
the following criteria, unless otherwise provided in 7.10.1.4:
(1) 	 Tactile signage shall be located at each exit door requiring an exit sign.
(2) 	 Tactile signage shall read as follows: EXIT
(3) 	 Tactile signage shall comply with ICC/ANSI A117.1, American National Standard
for Accessible and Usable Buildings and Facilities.
7.10.1.4 Existing Exemption. The requirements of 7.10.1.3 shall not apply to
existing buildings, provided that the occupancy classification does not change.
7.10.1.5 Exit Access.
7.10.1.5.1 Access to exits shall be marked by approved, readily visible signs
in all cases where the exit or way to reach the exit is not readily apparent to                  

National Fire Protection
Assn.
LIFE SAFETY CODE
(NFPA 101) - 2003
the occupants.
7.10.1.5.2* New sign placement shall be such that no point in an exit access
corridor is in excess of the rated viewing distance or 30 m (100 ft), whichever is less,
from the nearest sign.
7.10.1.6* Floor Proximity Exit Signs. Where floor proximity exit signs are required
in Chapter 11 through Chapter 42, such signs shall be located near the floor
level in addition to those signs required for doors or corridors. The signs shall be
illuminated in accordance with 7.10.5. Externally illuminated signs shall be sized
in accordance with 7.10.6.1. The bottom of the sign shall be not less than 150 mm
(6 in.) but not more than 455 mm (18 in. ) above the floor. For exit doors, the sign
shall be mounted on the door or adjacent to the door, with the nearest edge of
the sign within 100 mm (4 in.) of the door frame.
7.10.1.7* Floor Proximity Egress Path Marking. Where floor proximity egress path
marking is required in Chapter 11 through Chapter 42, a listed and approved
floor proximity egress path marking system that is internally illuminated shall be
installed within 455 mm (18 in.) of the floor. The system shall provide a visible
delineation of the path of travel along the designated exit access and shall be
essentially continuous, except as interrupted by doorways, hallways, corridors,
or other such architectural features. The system shall operate continuously or at
any time the building fire alarm system is activated. The activation, duration, and
continuity of operation of the system shall be accordance with 7.9.2.
7.10.1.8* Visibility. Every sign required in Section 7.10 shall be located and of such
size, distinctive color, and design that it is readily visible and shall provide contrast
with decorations, interior finish, or other signs. No decorations, furnishings,
or equipment that impairs visibility of a sign shall be permitted. No brightly
illuminated sign (for other than exit purposes), display, or object in or near the line
of vision of the required exit sign that could detract attention from the exit sign
shall be permitted.
7.10.1.9 Mounting Location. The bottom of new egress markings shall be located
at a vertical distance of not more than 2030 mm (80 in.) above the top edge of the
egress opening intended for designation by that marking. Egress markings shall
be located at a horizontal distance of not more than the required width of the
egress opening, as measured from the edge of the egress opening intended for
designation by that marking to the nearest edge of the marking.

7.10.2* Directional Signs. A sign complying with 7.10.3 with a directional
indicator showing the direction of travel shall be placed in every location where
the direction of travel to reach the nearest exit is not apparent.
7.10.3* Sign Legend.

7.10.3.1 Signs required by 7.10.1 and 7.10.2 shall read as follows in plainly legible
letters, or other appropriate wording shall be used:
                              
EXIT
7.10.3.2* Where approved by the authority having jurisdiction, pictograms shall be
permitted.

7.10.4* Power Source. Where emergency lighting facilities are required by the

applicable provisions of Chapter 11 through Chapter 42 for individual occupancies,
the signs, other than approved self luminous signs, shall be illuminated by the
emergency lighting facilities. The level of illumination of the signs shall be in
accordance with 7.10.6.3 or 7.10.7 for the required emergency lighting duration as
specified in 7.9.2.1. However, the level of illumination shall be permitted to decline
to 60 percent at the end of the emergency lighting duration.

7.10.5 Illumination of Signs.

7.10.5.1* General. Every sign required by 7.10.1.2 or 7.10.1.5, other than where
operations or processes require low lighting levels, shall be suitably illuminated by
a reliable light source. Externally and internally illuminated signs shall be legible in
both the normal and emergency lighting mode.
7.10.5.2* Continuous Illumination.
7.10.5.2.1 Every sign required to be illuminated by 7.10.6.3 and 7.10.7 shall be
continuously illuminated as required under the provisions of Section 7.8 unless
otherwise provided in 7.10.5.2.2.
7.10.5.2.2* Illumination for signs shall be permitted to flash on and off upon
activation of the fire alarm system.

7.10.6 Externally Illuminated Signs.
7.10.6.1* Size of Signs.
7.10.6.1.1 Externally illuminated signs required by 7.10.1 and 7.10.2, other than
approved existing signs, unless otherwise provided in 7.10.6.1.2, shall read EXIT, or
other appropriate wording shall be used, in plainly legible letters sized as follows:
(1) 	 For new signs, the letters shall be not less than 150 mm (6 in.) high, with the
principal strokes of letters not less than 19 mm (3/4 in.) wide.
(2) 	 For existing signs, the required wording shall be permitted to be in plainly
legible letters not less than 100 mm (4 in.) high.
(3) 	 The word EXIT shall be in letters of a width not less than 51 mm (2 in.), except
the letter I, and the minimum spacing between letters shall be not less than
9.5 mm ( /8 in. ) .
(4) 	 Sign legend elements larger than the minimum established in 7.10.6.1.1(1)
through 7.10.6.1.1(3) shall use letter widths, strokes, and spacing in proportion
to their height.
7.10.6.1.2 The requirements of 7.10.6.1.1 shall not apply to marking required by
7.10.1.3 and 7.10.1.6.
7.10.6.2* Size and Location of Directional Indicator.
7.10.6.2.1 Directional indicators, unless otherwise provided in 7.10.6.2.2, shall
comply with the following:
(1) 	 The directional indicator shall be located outside of the EXIT legend, not less
than 9.5 mm (3/8 in.) from any letter.
(2) 	 The directional indicator shall be of a chevron type, as shown in Figure
7.10.6.2.1.

(3) 	 The directional indicator shall be identifiable as a directional indicator at a
distance of 12m (40 ft).
(4) 	 A directional indicator larger than the minimum established for compliance with
7.10.6.2.1(3) shall be proportionately increased in height, width and stroke.
(5) 	 The directional indicator shall be located at the end of the sign for the direction
indicated.

FIGURE 7.10.6.2.1 Chevron-Type Indicator.
7.10.6.2.2 The requirements of 7.10.6.2.1 shall not apply to approved existing signs.
7.10.6.3* Level of Illumination. Externally illuminated signs shall be illuminated by
not less than 54 lux (5 ft-candles) at the illuminated surface and shall have a contrast
ratio of not less than 0.5.

7.10.7 Internally Illuminated Signs.

7.10.7.1 Listing. Internally illuminated signs shall be listed in accordance with UL 924,
Standard for Safety Emergency Lighting and Power Equipment, unless they meet one
of the following criteria:
(1) 	 They are approved existing signs.
(2) 	 They are existing signs having the required wording in legible letters not less
than 100mm (4 in.) high.
(3) 	 They are signs that are in accordance with 7.10.1.3 and 7.10.1.6.
7.10.7.2* Photoluminescent Signs.
The face of a photoluminescent sign shall be continually illuminated while the
building is occupied. The illumination levels on the face of the photoluminescent
sign shall be in accordance with its listing. The charging illumination shall be a
reliable light source as determined by the authority having jurisdiction. The charging
light source shall be of a type specified in the product markings.

7.10.8 Special Signs.
7.10.8.1 Sign Illumination.
7.10.8.1.1 Where required by other provisions of this Code, special signs shall be
illuminated.
7.10.8.1.2 Where emergency lighting facilities are required by the applicable
provisions of Chapter 12 through Chapter 42, the required illumination of special
signs shall additionally be provided under emergency lighting conditions.
7.10.8.2 Characters. Special signs, where required by other provisions of this Code,
shall comply with the visual character requirements of ICC/ANSI A117. 1 American
National Standard | for Accessible and Usable Buildings and Facilities.
7.10.8.3* No Exit.
7.10.8.3.1 Any door, passage, or stairway that is neither an exit nor a way of exit
access and that is located or arranged so that it is likely to be mistaken for an exit
shall be identified by a sign that reads as follows:                                              

NO

EXIT
7.10.8.3.2 The NO EXIT sign shall have the word NO in letters 51 mm (2 in.) high,
with a stroke width of 9.5 mm (3/8 in.), and the word EXIT in letters 25 mm (1 in.)
high, with the word EXIT below the word NO, unless such sign is an approved
existing sign.
7.10.8.4 Elevator Signs. Elevators that are a part of a means of egress (see 7.2.13.1)
shall have signs with a minimum letter height of 16 mm (5/8 in.) posted in every
elevator lobby as follows:
(1)	 *Signs that indicate that the elevator can be used for egress, including any
restrictions on use
(2)	 *Signs that indicate the operational status of elevators

7.10.9 Testing and Maintenance.

7.10.9.1 Inspection. Exit signs shall be visually inspected for operation of the
illumination sources at intervals not to exceed 30 days, or shall be periodically
monitored in accordance with 7.9.3.1.3.
7.10.9.2 Testing.
Exit signs connected to or provided with a battery-operated emergency illumination
source, where required in 7.10.4, shall be tested and maintained in accordance with
7.9.3.

85

Limited Warranty
		
	 	
		
	 Product	

Unit
Warranty	
(Years)	

Battery Warranty
Full	
(Years)	

Pro-Rata
(Years)

Liteforms Emergency Lighting Units

	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	

LiteScape Series	
with Spectron option	
nicad battery models	
nicad with Spectron option	
EZ-2 Series	
with Spectron option	
LZ Series	
with Spectron option	
LZ High Capacity Series	
with Spectron option	
nicad battery models	
nicad with Spectron option	
LM Series
lead-calcium battery models	
lead-calc. with Spectron option	
nicad battery models	
nicad with Spectron option	
EZ-2R Series	
with Spectron option	
T-Grid Series	
with Spectron option	
EXT-122-EM Series	
Lite2 Series	
with Spectron option	
Delite Series	
N4X Series	
with Spectron option	
AS Series	
with Spectron option	
wet lead-acid battery models	
wet lead-acid with Spectron option	
wet nicad battery models	
wet nicad with Spectron option	
IPS Series	
XPB Series	
UFO-3AW, UFO-4W models	
UFO-5W, UFO-12W models	
UFO-5AW models	
UFO-6W, UFO-6WI,	
UFO-6W-CLD, UFO-7W, 	
UFO-7WI, UFO-LP 	
and UFO-MH models 	

	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	

LX LED exit 	
AC-Only models	
Emergency models	
Emergency Spectron models	
DK incandescent exit
AC-Only models	
Emergency models	
LT combo exit 	
Spectron models	
NYXC combo exit 	
SMC combo exit 	
Sempra cast LED exit* 	
AC-Only models	
Emergency models	
Emergency Spectron models	
NYDC cast LED exit 	
AC-Only models	
Emergency models	
LN4X wet location LED exit 	
AC-Only models	
Emergency models	
Emergency Spectron models	
Freedom LED aluminum exit
AC-Only models	
Emergency models	
LEDS aluminum LED exit
AC-Only models	
Emergency models	

1	
5	
1	
5	
3	
5	
1	
5	
1	
5	
3	
5	

1	
2	
1	
2	
3	
5	
1	
5	
1	
2	
1	
2	

5
4
9
4
3
5
5
5
5
4
9
8

1	
5	
3	
5	
3	
5	
3	
5	
1	
3	
5	
1	
3	
5	
1	
5	
1	
5	
1	
5	
3	
3	
1	
2	
3	
5	
“	
“	
“	

1	
2	
1	
2	
3	
5	
3	
5	
1	
3	
5	
1	
3	
5	
1	
2	
1	
2	
1	
2	
3	
3	
1	
2	
3	
5	
“	
“	
“	

5
4
9
8
3
5
3
5
5
3
5
5
3
5
5
4
9
8
14
13
3
3
–
–
–
–
–
–
–

5	
5	
5	

–	
1	
2	

–
9
8

3	
5	
5	
5	
5	
5	

–	
1	
1	
2	
1	
1	

–
9
5
4
5
5

Liteforms Exit Signs

5	
–	
–
5	
1	
9
5	                   Lifetime
5	
5	

–	
1	

–
9

5	
5	
5	

–	
1	
2	

–
9
8

5	
5	

–	
1	

–
4

5	
5	

–	
1	

–	
9

	 * Includes Sempra, Sempra SC, SC-WL, MR and SERS Series exit signs.
	

86

	 		
		
Unit
		
Warranty	
	 Product	
(Years)	

Battery Warranty
Full	
(Years)	

Pro-Rata
(Years)

5	
5	

–	
1	

–	
9

5	
5	

–	
1	

–	
9

5	
5	
5	

–	
1	
2	

–	
9
8

5	

–	

–

5	
5	

–	
1	

–
9

5	
5	

–	
1	

–
9

3	
3	

–	
1	

–
5

Liteforms Exit Signs

	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	

NYX LED exit
AC-Only models	
Emergency models	
CMX exit
AC-Only models	
Emergency models	
LE edge-lit LED exit
AC-Only models	
Emergency models	
Emergency Spectron models	
LES edge-lit LED exit 	
AC-Only models	
NYE edge-lit LED exit 	
AC-Only models	
Emergency models	
NYES edge-lit LED exit 	
AC-Only models	
Emergency models	
DEX special wording exit 	
AC-Only models	
Emergency models	

	
	
	
	
	
	
	
	
	
	
	
	
	

SlimLite Series	
CV Series	
CVEC Series	
CV3 LED exit 	
AC-Only models	
Emergency models	
CVT Tandem LED exit 	
CVD cast LED exit 	
AC-Only models	
Emergency models	
CVER edge-lit LED exit 	
AC-Only models	
Emergency models	

Clearview Life Safety Products
1	
1	
1	

1	
1	
1	

5
5
5

5	
5	
5	

–	
1	
1	

–
9
9

5	
5	

–	
1	

–
9

5	
5	

–	
1	

–
9

Consult factory for warranties available with AC Inverter Systems.

Emergency Lighting Units and Batteries

Dual-Lite warrants to the purchaser that its products have been carefully manufactured and
inspected, and are warranted to be free from defect of workmanship and materials when used
as intended. See chart at left for duration of warranties for units and batteries (fuses and lamps
are excluded from all warranties).
Batteries must be placed in service or recharged within nine (9) months from invoice date or
ninety (90) days from recommended recharge date stamped on carton, whichever is longer
(NiCad batteries excluded).
The warranties are subject to proper installation and maintenance in accordance with the
instructions supplied. Any abuse or misuse contrary to normal operation shall void this
warranty.
This warranty does not cover damages caused by installation in areas with other than normal
temperatures and environmental conditions per application specifications. Dual-Lite assumes
no responsibility for any damage to people, property, apparatus or otherwise resulting from
improper installation or maintenance of its emergency lighting units.
Warranty coverage shall not apply to any equipment of another manufacturer used in conjunction
with Dual-Lite systems.
Warranty does not cover damages caused by abuse, fire or acts of God.
To obtain prior written approval to return defective items, please contact your local manufacturer’s
representative. After prior written notification has been given and approval obtained for the
return, merchandise may be returned, freight prepaid, to Dual-Lite.
Customer is responsible for secure packaging of returned materials to provide best possible
assurance against breakage in shipment.
If, upon inspection, the merchandise is found to be defective replacement or repair shall be
made. Dual-Lite’s sole obligation under this limited warranty is to repair or replace the defective
parts or products, at its discretion, providing such defective parts or products are brought to
its attention within the specified warranty time period, and does not include any other costs
such as removal of defective parts or product, installation, labor or consequential damages of
any kind, the exclusive remedy being to require such new parts or products to be furnished. All
other warranties, expressed or implied, including warranties of merchantability or warranties
of fitness for any particular purpose we hereby disclaim.
Dual-Lite Distributors and Representatives have no authority to change this warranty without
written permission from Dual-Lite.
Dual-Lite reserves the right to determine the best method of correcting warranty problems.
All specifications subject to change without notice.
Some states do not allow the exclusion of limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you. This warranty gives you specific legal
rights, and you may also have other rights which vary from state to state.

Synchron Series Single-Phase Inverters ............................................. 88 to 91
Spectron LSN Series Single-Phase Inverters .................................... 92 to 101
Trident Series Three-Phase Inverters .................................................... 103 to 106
Auxiliary Transfer Switching Device ................................................................... 107

87

Single Phase Systems

88

Single Phase Systems

89

Single Phase Systems

90

Single Phase Systems

91

Single Phase Systems

92

Single Phase Systems

93

Single Phase Systems

94

Single Phase Systems

95

Single Phase Systems

96

Single Phase Systems

97

Single Phase Systems

98

Single Phase Systems
Note: Batteries for all Spectron LSN inverter
systems are shipped separately.
Batteries must be installed and energized within six
months of shipment or warranty is void.

99

Single Phase Systems

100

Single Phase Systems

101

Three Phase Systems

102

TRX Three Phase Systems
3-Phase
rident
Inverter Power Systems

GENERAL SPECIFICATIONS
INPUT

Voltage:
120/208VAC, 60Hz 3-phase, 4-wire
plus ground
Voltage Range: +10%, -20%
Frequency Range: 47-63Hz.

User Interface Panel

Current Distortion:
4% maximum reflected THD at
full load
Current Limit:
125% of full load input current
Walk-ln: 20 seconds to full load
Power Factor:
0.99 lagging minimum at full load
Surge Protection:
Sustains input surges without damage,
per criteria listed in IEC 1000-4-5

ENVIRONMENTAL
Operating Temperature:
UPS: 32°F to 104°F (0°C to 40°C)
Battery: 68°F to 86°F (20°C to 30°C)
Relative Humidity:
0-95% non-condensing

TRX Series
10 to 30 kVA, 3-Phase UPS
Flexibility In Application
The Dual-Lite Trident TRX Series’
quiet operation, small footprint
and lightweight design is perfect
for installation in computer rooms,
yet the Trident TRX Series is
rugged enough for factory floors
or maintenance rooms. Precisely
controlled system output is suitable
for any lighting or critical life safety
loads up to the full rated output
capacity.
Outstanding Features
• 	 Unmatched reliability
• 	 Smallest system footprint
• 	 Excellent efficiency with nonlinear
and partial loads
• 	 Outstanding dynamic response
• 	 All-digital ActiveStar controls and
graphical user interface
• 	 Power factor corrected
• 	 Harmonic current cancellation

Operating Altitude:
Up to 3,300 ft. (1,000m)
without derating
Acoustical Noise:
Less than 54 dBA typical, measured 3.3
ft. (1 m) from the unit

OUTPUT
Voltage:
120/208VAC, 60Hz., 3-phase, 4-wire
plus ground
Voltage Adjustment Range: ±5%
Voltage Regulation:
1% for balanced load
2% for 100% unbalanced load
Dynamic Regulation:
±4% deviation for 100% load step
±1% for loss or return of AC input
Transient Response Time:
Recover to ±1% of steady state within
1 cycle
Voltage Distortion:
For linear loads, 1% THD. Less than
4% THD for 100% nonlinear loads
without kVA/kW derating
Phasing Balance:
120° ±0.5° for balanced load
120° ±1° for 100% unbalanced load
Frequency Regulation: ±0.1%
Load Power Factor Range:
0.70 lagging to 0.95 leading without
derating
Overload:
125% of full load for 10 minutes
150% for one minute, with true
sinusoidal waveform
Outstanding Support
Assistance is available from the
largest Customer service and Support
network in the country.
Standards
Complies with UL 1778 (UPS) and UL
924 (Emergency) standards, and is
CSA certified.

103

TRX Three Phase Systems
Product Selector
Size kVA/kW	

UPS Cabinet No.	

Battery Cabinet No. (1)

	

10/8	

TRXSAA10114	

TRXBATAR141BNR

	

15/12	

TRXSAB10114	

TRXBATBR271BNR

	

20/16	

TRXSAC10114	

TRXBATCR371BNR

	

30/24	

TRXSAD10114	

TRXBATDR311BNR(2)

(1) 90 minute run time. Contact factory for other run times.
(2) Two battery cabinets required on 30 kVA models

Options

480 VAC Operation (Contact factory for proper configuration)
Intellislot Relay Board
Seismic Floor Kit

Site Planning Data	

Trident UPS - 90 Minute Operation

	          Battery	
	
	 System	
	 AC		
	
	 AC Input	 	
(1)
   	 Rating	
	Voltage       	
	
	 Current	 	
Nom.	 Battery	
Max.	
	 kVA	 	 kW	 Input	 	Output	   Nom.	 	 Max.	 OCPD	 VDC	 kW	
Discharge	

10-30 kVA, 3-Phase, 60 Hz.

AC Output	
	
Mechanical Data
	 Current	 	         No. Of           Dimensions - WxDxH	Weight	
Heat Dis
Nom.	 	 OCPD  	 Cabinets	
inches (mm)	
Ibs. (kg)	

BTU/hr (kWH)

	 10		 8	

208		 208	

28		

35	

50	

288	

9	

37A	

28		 50	

2	

51x32.5x63 (1,295x826x1,600)	 2,800 (1,275)	

2,800 (0.82)

	 15		 12	

208		 208	

42		

53	

60	

288	

13	

55A	

42		 60	

2	

51x32.5x63 (1,295x826x1,600)	 3,350 (1,526)	

4,200 (1.23)

	 20		 16	

208		 208	

56		

70	

80	

288	

18	

73A	

56		 80	

2	

83x32.5x63 (2,057x826x1,600)	 4,150 (1,890)	

5,500 (1.61)

	 30		 24	

208		 208	

83		 104	

125	

288	

26	

110A	

83		 125	

3	

142x32.5x63 (1,981x826x1,600)	 6,650 (3,028)	

8,300 (2.43)

--		 1,3,7	

--	

--	

-- 	

1,3,7	

See Notes For Table (Below): 	

1,3,7		

6	

--	

--	

--	

--

(1) Contact factory for 480 VAC applications.

Cabinet Configurations

	 10 and 15 kVA Models	

20 kVA Models	

30 kVA Models

NOTES FOR TABLE:

1. 	 UPS input and bypass cables must be run in separate conduit from output cables
2. 	 Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized ground conductors are recommended. Neutral conductors to be sized for full capacity per
NEC 310-15 (b)(4). References are per NEC 1999.
3. 	 Wiring requirements:
		
AC Input: 3-phase, 4-wire, plus ground
		
AC Output: 3-phase, 3- or 4-wire, plus ground
4.	 All wiring is to be in accordance with national and local electric codes.
5. 	 Minimum access clearance is 3 ft. (0.9m) front and 18 in. (457mm) above the UPS.
6. 	 Top or bottom cable entry through removable access plates. Punch plate to suit conduit size, then replace.
7. 	 Control wiring and power wiring must be run in separate conduit.

ADDITIONAL NOTES:

• 	 If site configuration includes a backup emergency generator, it is recommended that the engine generator set be properly sized and equipped for a UPS application.
Generator options would typically include an isochronous governor (generator frequency regulation) and a UPS-compatible regulator (generator voltage regulation).
Consult generator manufacturer for required generator options and sizing.
• 	 If site configuration includes an automatic transfer switch, refer to Power Line titled “Criteria for Application of Automatic Transfer Switches (ATS) With Uninterruptible
Power Supply (UPS) Systems,” publication 91K-PLT-48-02. It is also recommended that the transfer switch be equipped with auxiliary contacts for UPS “on generator”
current limit. Consult transfer switch manufacturer for required transfer switch options and sizing.
• 	 If site configuration requires an external isolated maintenance bypass circuit, it should be noted that utility AC input might not be in phase with the UPS AC output.
Consult a Dual-Lite sales representative or applications engineer.

104

TRN Three Phase Systems
3-Phase
rident
Inverter Power Systems

GENERAL SPECIFICATIONS

INPUT
Voltage: 208 or 480 VAC, 60 Hz (3-phase,
3-or 4-wire plus ground)
Voltage Range: +10, -15% (no battery
discharge at-20%)
Frequency Range: 60 Hz, ± 5
Current Distortion: 10% maximum
reflected THD at full load with optional
input filter. 30% THD without filter
Current Limit: 115% of full load
input current
Current Walk-in: 20 seconds to full load
Power Factor: 0.80 lagging minimum at
full load. Up to 0.96 lagging at full load
with optional input filter
Surge Protection: Sustains input surges
without damage, per criteria 		
listed in ANSI C62.41-1980 (IEEE 587)

TRN Series
30 to 130 kVA, 3-Phase UPS
•	 Unmatched heritage of 	
	
	 reliability and availability
•	 Smallest system footprint
•	 Excellent efficiency with 	
	
	 nonlinear loads and partial loads
• 	Outstanding dynamic response
• 	All-digital controls and graphical 	
	 user interface
Dual-Lite has reinvented the dualconversion UPS. The TridentTM Series is
the result of an international design
collaboration and more than a decade of
advanced research.
Every aspect of the TridentTM Series shows
careful design and attention to detail.
The rugged power train and advanced
DSP controls were subjected to computer
simulations and thermal analysis to
ensure reliable performance in every
environment.
Even the physical packaging is uniquely
efficient, to make fully configured systems
more compact than our competitors.
Best of all, it’s a Dual-Lite product designed to deliver an impressive millionhour critical bus MTBF.

Voltage Distortion: For linear loads,
1% THD. Less than 2.5% THD for 100%
nonlinear loads without kVA/kW derating
Phasing Balance: 120° ±0.5° for balanced
load. 120° ±1° for 100% unbalanced load
Frequency Regulation: ±0.1%
Load Power Factor Range: 1.0 to 0.7
lagging without derating
Overload: 125% of full load for ten
minutes. 150% for one minute, with true
sinusoidal waveform
STANDARDS
Complies with UL 1778 (UPS) and UL 924
(Emergency) standards, and is CSA certified.

ENVIRONMENTAL
Operating Temperature: 0° to 40°C (UPS),
20° to 30°C (battery)
Non-Operating Temperature: -20°C
to 70°C
Relative Humidity: 0-95% non-condensing
Operating Altitude: Up to 6,600 feet
(2000 meters) without derating
Acoustical Noise: Less than 65 dBA 1
meter from unit (typical)
OUTPUT
Voltage: 208 or 480 VAC (3-phase, 4-wire
plus ground)
Voltage Adjustment Range: ±5%
Voltage Regulation:
	
±0.5% for balanced load
	
±1.0% for 100% unbalanced load
Dynamic Regulation: ±2.5% deviation for
100% load step.
	
±1% for loss or return of AC input
Transient Response: Recover to ±1% of
steady state within 1 cycle

Slim-Line Distribution Cabinet
	 kVA	
	
	
	 All	

Dimensions (In.)	
(WxDxH)	
10 x 32.5 x 71	

Weight
(Ib)
250

Maintenance Bypass Cabinets
	 Model	
	
	
	
L	
	
N	
	
P	
	
Q	

Dimensions (In.) 	
(WxDxH)	
25 x 32.5 x 71	
25 x 32.5 x 71	
31.7 x 32.5 x 71	
31.7 x 32.5 x 71	

Weight (Ib) 	
15-50 kVA	
660	
660	
1,210	
1,210	

Weight (Ib) 	
65-80 kVA	
750	
750	
1,320	
1,320	

Weight (Ib)
100-130 kVA
800
800
1,540
1,540

105

TRN Three Phase Systems
Product Selector
Size kVA/kW	
	 30/24	
	 40/32	
	 50/40	
	 65/52	
	 80/64	
	 100/80	
	 130/104	

UPS Cabinet No. (480/480)	
TRNSAD2026B	
TRNSAE2026B	
TRNSAF2026B	
TRNSAG2026B	
TRNSAH2026B	
TRNSAI2026B	
TRNSAJ2026B	

UPS Cabinet No. (208/208)	
TRNSAD1016B	
TRNSAE1016B	
TRNSAF1016B	
TRNSAG1016B	
TRNSAH1016B	
TRNSAI1016B	
TRNSAJ1016B	

Battery Pack No.*
TRNBATDX471BNL
TRNBATEX312BNL
TRNBATFX372BNL
TRNBATGX472BNL
TRNBATHX274BNL
TRNBATIX473BNL
TRNBATJX474BNL

* 90 minute run time. Contact factory for other run times.

Options

Programmable Relay Board
Internal Modem
Network Interface Card
AS/400 Signal Cable
Remote Alarm Status Panel

Cabinet Configurations
30 kVA Models

40 - 50 kVA Models

65 kVA Models

Site Planning Data

80 kVA Models

Trident UPS - 90 Minute Operation

	      Battery	
	
System	               AC		
	
	 AC Input	 	
     Rating	
	Voltage       	 	
	 Current	 	
Nom.	 Battery	
Max.	
	 kVA	 	 kW	 Input	 	Output	   Nom.	 	 Max.	 OCPD	 VDC	 kW	
Discharge	
	 30		 24	 208		 208	
80		 92	
150	 480	
26	
66A	

30-130 kVA, 3-Phase, 60 Hz.

AC Output	
	
Mechanical Data
	 Current	 	           No. Of           Dimensions - WxDxH    Weight            Heat Dis
Nom.	 	  OCPD  	 Cabinets	
inches (mm)	
Ibs. (kg)	
BTU/hr (kWH)
83		 125	
2	
80.7x32.5x71 (2,050x826x1,803)	 7,250 (3,303)	 8,500 (2.49)

	 30		 24	

480		 208	

33		

38	

60	

480	

26	

66A	

83		 125	

2	

80.7x32.5x71 (2,050x826x1,803)	 7,150 (3,257)	

	 30		 24	

480		 480	

33		

38	

60	

480	

26	

66A	

36		 50	

2	

80.7x32.5x71 (2,050x826x1,803)	 6,950 (3,166)	 11,000 (3.22)

7,500 (2.19)

	 40		 32	

208		 208	

106		 122	

175	

480	

34	

88A	

111		 150	

3	

130x32.5x71 (3,294x826x1,803)	 9,600 (4,373)	 11,000 (3.22)

	 40		 32	

480		 208	

44		

51	

80	

480	

34	

88A	

111		 150	

3	

130x32.5x71 (3,294x826x1,803)	 9,500 (4,328)	 10,000 (2.93)

	 40		 32	

480		 480	

44		

51	

80	

480	

34	

88A	

48		 60	

3	

130x32.5x71 (3,294x826x1,803)	 9,300 (4,237)	 10,000 (2.93)

	 50		 40	

208		 208	

133		 153	

225	

480	

43	

109A	

139		 175	

3	

130x32.5x71 (3,294x826x1,803)	 10,200 (4647)	 14,000 (4.10)

	 50		 40	

480		 208	

55		

63	

90	

480	

43	

109A	

139		 175	

3	

130x32.5x71 (3,294x826x1,803)	 10,100 (4601)	 12,000 (3.51)

	 50		 40	

480		 480	

55		

63	

90	

480	

43	

109A	

60		 80	

3	

	 65		 52	

208		 208	

171		 196	

300	

480	

55	

141A	

180		 25	

3	

137.4x32.5x71 (3,490x826x1,803)	 12,800 (5831)	 18,000 (5.27)

	 65		 52	

480		 208	

70		

81	

125	

480	

55	

141A	

180		 225	

3	

137.4x32.5x71 (3,490x826x1,803)	 12,600 (5740)	 15,000 (4.39)

	 65		 52	

480		 480	

70		

81	

125	

480	

55	

141A	

78		 100	

3	

137.4x32.5x71 (3,490x826x1,803)	 12,400 (5649)	 15,000 (4.39)

	 80		 64	

208		 208	

210		 241	

350	

480	

68	

174A	

222		 300	

5	

139.4x32.5x71 (3,541x826x1,803)	 14,700 (6697)	 22,000 (6.44)

	 80		 64	

480		 208	

87		 100	

150	

480	

68	

174A	

222		 300	

5	

139.4x32.5x71 (3,541x826x1,803)	 14,500 (6606)	 18,000 (5.27)

	 80		 64	

480		 480	

87		 100	

150	

480	

68	

174A	

96		 125	

5	

139.4x32.5x71 (3,541x826x1,803)	 14,300 (6515)	 18,000 (5.27)

	 100		 80	

208		 208	

261		 300	

500	

480	

85	

218A	

278		 350	

4	

196.2x32.5x71 (3,713x826x1,803)	 18,950 (8633)	 26,000 (7.61)

	 100		 80	

480		 208	

108		 124	

200	

480	

85	

218A	

278		 350	

4	

196.2x32.5x71 (3,713x826x1,803)	 18,750 (8542)	 21,000 (6.14)

	 100		 80	

130x32.5x71 (3,294x826x1,803)	 9,900 (4510)	

12,000 (3.51)

480		 480	

108		 124	

200	

480	

85	

218A	

120		 150	

4	

196.2x32.5x71 (3,713x826x1,803)	 18,550 (8451)	 21,000 (6.14)

	 130		 104	 208		 208	

339		 390	

600	

480	

111	

283A	

361		 450	

5	

245.2x32.5x71 (6,228x826x1,803)	 24,000 (10934)	 33,000 (9.66)

	 130		 104	 480		 208	

140		 161	

250	

480	

111	

283A	

361		 450	

5	

245.2x32.5x71 (6,228x826x1,803)	 23,800 (10843)	 27,000 (7.90)

	 130		 104	 480		 480	

140		 161	

250	

480	

111	

283A	

156		 200	

5	

245.2x32.5x71 (6,228x826x1,803)	 23,600 (10751)	 27,000 (7.90)

--	

--	

-- 	

1,3,7	

1,3,7		

--	

See Notes For Table (Below): 	

--		 1,3,7	

NOTES FOR TABLE:
1. 	 The unit’s input and bypass cables must be run in separate conduit from
output cables.
2. 	 Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized
ground conductors are recommended. Neutral conductors to be sized for full
capacity per NEC 310-15(b)(4). References are per NEC 1999.
3. 	 Wiring requirements:
	 AC Input: 	
3-phase, 3-wire plus ground or 3-phase, 4-wire plus ground
	 AC Output:	
3-phase, 4-wire plus ground
	 DC Input: 	
2-wire (positive and negative), plus ground
4. 	 All wiring is to be in accordance with national and local electrical codes.
5. 	 Minimum access clearance is 3 feet front and 1 foot above the unit.
6. 	 Top or bottom cable entry through removable access plates. Cut plate to suit
conduit size then replace.
7. 	 Control wiring and power wiring must be run in separate conduit.
8. 	 Weights and dimensions shown include battery cabinets.
9.	 OCPD-Overcurrent Protection Device.

106

130 kVA Models

100 kVA Models

--	

8	

8	

--

ADDITIONAL NOTES:
• 	 If site configuration includes a back-up emergency generator, it is recommended
that the engine generator set be properly sized and equipped for the unit’s
application. Generator options would typically include an isochronous governor
(generator frequency regulation) and a UPS-compatible regulator (generator
voltage regulation). Consult generator manufacturer for required generator
options and sizing.
• 	 If site configuration includes an automatic transfer switch, refer to the Power
Line titled “Criteria for Application of Automatic Transfer Switches (ATS) with
Uninterruptible Power Supply (UPS) Systems” publication 91K-PLT-48-02. It is also
recommended that the transfer switch be equipped with auxiliary contacts for
the unit’s “on generator“ current limit. Consult transfer switch manufacturer for
required transfer switch options and sizing.
• 	 If site configuration requires an external isolated maintenance bypass circuit,
it should be noted that utility AC input may not be in phase with the unit’s AC
output. Consult local sales representative or applications engineer.

ATSD

Auxiliary Transfer Switching Device
Features
• Device allows generator or inverter
supplied egress lighting fixtures to
be switched
• For factory or field installation
• Compatible with all
	 fluorescent fixtures
• Easy installation inside of
	 ballast channel
• For use with switched fluorescent
lighting fixtures

•
	
•
•
•

Battery case made of
galvanized steel
Universal 120/277VAC operation
Low power consumption
Temperature range: 0°C to 50°C 	
		
(32°F to 122°F)

• UL Listed

Ordering Information
ATSD

Installation
The ATSD auxiliary transfer device does not affect normal fixture operation and comes fully assembled to mount in the fixture
ballast channel. In addition to available wiring, the device requires a direct, unswitched connection to a generator- or invertersupplied emergency panel and an unswitched source on the same branch circuit as the switched supply (see diagram below).

Application

Dimensions

8.0”
20.4cm

1.18”
3.0cm

1.18”
3.0cm

The ATSD auxiliary transfer switching device
works in conjunction with an auxiliary generator
or inverter power system to power existing
fluorescent fixtures for egress lighting regardless
of fixture wall switch position. The device consists
of relay switching circuitry and fusing in one
compact galvanized steel case. One auxiliary
transfer switch device per fixture can be used to
bypass fixture wall switch allowing the building’s
generator to bring on switchable fixtures and not
just those on “night-light” circuits. The auxiliary
transfer switch device is suitable for use in indoordry or damp location fixtures. Recommended
applications include: auditoriums, classrooms, or
any other location with generator- or invertersupplied emergency lighting.

107

Notes

108

Notes

109

Notes

110

Dual-Lite • A Hubbell Lighting, Inc. Life Safety Products Brand • www.dual-lite.com
Copyright© Hubbell Lighting, Inc., All Rights Reserved • Specifications subject to change without notice. • Printed in U.S.A.	

0603254

3/06



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23
Instance ID                     : uuid:431f8474-c5b6-4aff-9ce1-d1a4a38b0921
Document ID                     : adobe:docid:indd:d4117685-aeb2-11da-8710-e2d54255d799
Rendition Class                 : proof:pdf
Derived From Instance ID        : d4117684-aeb2-11da-8710-e2d54255d799
Derived From Document ID        : adobe:docid:indd:c20d943a-ae8b-11da-8710-e2d54255d799
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches
Manifest Reference Document ID  : adobe:docid:photoshop:fad6cb1b-0412-11da-ac88-afb10cd33dca, adobe:docid:photoshop:5adc27cf-149c-11da-bef5-fe11c0148134, adobe:docid:photoshop:0dc90bbc-0c4e-11d8-900f-cb75de43c9a9, adobe:docid:photoshop:ffebb212-3b6b-11d8-8729-8425211b5967
Create Date                     : 2007:06:19 17:00:38-04:00
Modify Date                     : 2007:06:19 18:06:52-04:00
Metadata Date                   : 2007:06:19 18:06:52-04:00
Creator Tool                    : Adobe InDesign CS2 (4.0.5)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 7675 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Has XFA                         : No
Page Count                      : 112
Creator                         : Adobe InDesign CS2 (4.0.5)
EXIF Metadata provided by EXIF.tools

Navigation menu