56178 Catalog
10205-Catalog 10205-Catalog 10205-Catalog 782520 Batch5 unilog cesco-content
56178-Catalog 56178-Catalog 56178-Catalog 782520 Batch12 unilog cesco-content
2014-11-11
: Pdf 56178-Catalog 56178-Catalog Batch12 unilog
Open the PDF directly: View PDF
.
Page Count: 112
| Download | |
| Open PDF In Browser | View PDF |
To be an
innovator,
first you have to
listen
to what
your
customers
say.
I
nnovation doesn’t happen by
chance. Yes, it takes experience...
dedication to quality... and a
willingness to think “outside the box.”
But if you’re going to continually
set industry standards, that thinking
had better reflect what your
customers expect.
Which is why at Dual-Lite,
innovation begins with listening
carefully to our customers.
About Our Products
All our latest products began with nationwide customer interviews to find out what you want and need...and
what you think. We then took this product-shaping feedback, factored in our own high standards for quality,
and developed products by which others are now measured. As you review our product offerings, you’ll see that
this strong tradition of excellence continues today with exit signs and emergency lighting that include the latest
advances and the highest level of performance.
About Our Quality
Quality is the key reason why Dual-Lite remains the industry’s most asked-for brand. You’ll see it in our construction, components, design and engineering, all of which combine to deliver the highest level of customer satisfaction, and the industry’s best safety record.
Number One Brand
It’s our unique “listen-to-learn” business philosophy that’s made Dual-Lite the industry’s Number One brand ...and
why our name still remains synonymous with life safety excellence after more than 65 years.
2
A Tradition Of Excellence
Sleek lines... low-profile silhouette... innovative design...
Only one line of life safety equipment fits this description
—the Liteforms® Collection by Dual-Lite.
Our unique styling is backed up by the substance of
high-quality, high-performance components and sturdy
construction features that helps ensure long-life, worryfree operation and lower maintenance expense. Plus,
with our extensive product offering, you’ll find a
Liteforms exit sign or emergency lighting unit for nearly
every commercial, industrial or institutional application.
That’s the LiteForms tradition of excellence
LiteForms, delivering the perfect solutions to all your life
safety product needs.
Collection
Focused On Value
For many, value equates to cost-effective products that
perform reliably.
For others, value means lowering transaction costs and
minimizing returns.
For everyone, value is simply having your expectations met
or exceeded every time.
Everything about Dual-Lite’s Clearview Collection is
focused on delivering the type of value and high output
performance that our customers have come to expect.
Additionally, Clearview Collection products share a “family”
style that results in a unified designer look when they are
installed together. With Clearview products, you can create
life safety lighting systems with eye appeal.
Value... Performance... Style...
That’s the Clearview difference.
Protection From Severe
Conditions
Whether your need is a vandalresistant exit sign, explosion-proof
emergency lighting, or units that can
withstand damp, exposed or hazardous
conditions, the solution is the Ultrex
line, from Dual-Lite.
Ultrex features products for almost
every severe condition you’ll
encounter.
Each Ultrex unit is designed to provide
unsurpassed, worry-free performance
and lower maintenance —
also lowering
costs.
Ultrex Choices
Dual-Lite offers a broad choice
of products for severe condition
applications, including:
Emergency Lighting Units
• EZ-2 Damp Series
• LZ Damp Series
• LM Damp Series
• N4X Series
• IPS Series
• XPB Series
• Lampak Series
Exit Signs
LX Series
• LT Series
• LN4X Series
• Sempra SC Series
• Sempra SC WL Series
• Freedom LED Series
• LEDS Series
•
Remote Lighting Heads
GNX Series
• OMS Series
•
Features
• Meets UL 924 standards for self-testing/self diagnostic
models.
Self-Testing/Self-Diagnostic
Electronics System
• Provides automatic self-diagnostic monitoring and
testing of unit operation.
• Automatically performs routine maintenance and
assures operational readiness at all times.
• Monitors charger and lamp operation.
• Routine discharge cycles insure optimum battery
performance and maximum useful life.
• Automatic self-test every 28 days and extended
operation self-test every 6 months.
• Automatic low voltage disconnect.
• Automatic unit transfer in brownout conditions.
• Automatic 15-minute retransfer delay (units).
Technologically advanced self-testing, self-diagnostic
electronics provide increased reliability and decreased
maintenance.
All Dual-Lite models ordered with the Spectron
option provide:
• Visual indication of AC power status
• Visual Indication of all self-diagnostic test cycles
• Visual indication of unit malfunctions including:
• Battery disconnected
• Battery fault
• Charger fault
• Transfer fault
• Lamp fault
• Automatic AC lockout circuit.
• Flashing LED indication of unit malfunction.
• All detected malfunctions retained in memory until
corrected and retested.
• Test switch allows a system check at any time.
• Supports exit sign flashing options
Test Intervals
The Spectron self-testing/self-diagnostic system conducts
tests to verify proper operation continuously and on
monthly, and semiannual intervals. Manual tests may also
be performed at any time. A malfunction during any self
test will be indicated by the external status indicators .
Emergency
Lighting Units
LiteForms Emergency Lighting Units
LiteScape Series
EZ-2 Series
LZ Series
LZ (HC) Series
LM Series
EZ-2R Series
T-Grid Series
EXT Series
Lite2 Series
Delite Series
N4X Series
AS Series
IPS Series
XPB Series
Lampak Series
Exit
Signs
Emergency
Lighting
Emergency
Lighting
Guaranteed Code Compliant Emergency Lights.................................................. 14, 15
Commercial Emergency Lights..................................................................................16
Designer Emergency Lights.................................................................................................. 17
High Capacity Designer Emergency Lights.......................................................... 18, 19
High Capacity Emergency Lights........................................................................ 20, 21
Recessed Emergency Lights.................................................................................................. 22
Recessed T-Grid Emergency Lights. ...........................................................................23
Recessed Gimbal Emergency Light............................................................................24
Emergency Lighting Square Units.................................................................... 25
Emergency Lighting Cylinder Units...........................................................................26
Harsh Environment Emergency Lights.......................................................................27
Industrial Emergency Lights.............................................................................. 28, 29
Wet Location Emergency Lights. ....................................................................... 30, 31
Explosion-Proof Emergency Lights..................................................................... 32, 33
Fluorescent Power Packs. .....................................................................34 to 38
LiteForms Exit Signs
LX Series
DK Series
LT Series
NYXC Series
SMC Series
Sempra Series
Sempra MR Series
Sempra SC Series
Sempra SCWL Series
Sempra SERS Series
NYDC Series
LN4X Series
Freedom LED Series
LEDS Series
NYX Series
CMX Series
LE Series
LES Series
NYE Series
NYES Series
DEX Series
Designer LED Exit Signs........................................................................................................ 40
AC Incandescent Exit Signs................................................................................................... 41
Designer Tandem Units..................................................................................... 42, 43
New York Tandem Units. .........................................................................................44
Tandem Units with Side Mounted Heads...................................................................45
Diecast LED Exit Signs.................................................................................................... 46, 47
Master/Remote Diecast LED Exit Signs......................................................................... 48, 49
Severe Conditions Diecast LED Exit Signs..................................................................... 50, 51
Wet Location Diecast LED Exit Signs.................................................................................... 52
Recessed Diecast LED Exit Signs........................................................................................... 53
New York Diecast LED Exit Signs......................................................................................... 54
Wet Location LED Exit Signs.....................................................................................55
Aluminum LED Exit Signs..................................................................................................... 56
Low-Profile Aluminum LED Exit Signs. ......................................................................57
New York LED Exit Signs..........................................................................................58
Chicago Exit Signs ...................................................................................................59
Recessed Mounting Edge-Lit LED Exit Signs................................................................ 60, 61
Surface Mounting AC Edge-Lit LED Exit Signs............................................................. 62, 63
New York Recessed Mounting Edge-Lit LED Exit Signs...................................................... 64
New York Surface Mounting Edge-Lit LED Exit Signs......................................................... 65
Special Wording Incandescent Exit Signs...................................................................66
Clearview Emergency Lighting Products
Remote Heads,
Fixtures and
Accessories
SlimLite Series
CV Series
CVEC Series
CV3 Series
CVT Series
CVD Series
CVER Series
Fixed Lens Emergency Lights...................................................................................68
Emergency Lights....................................................................................................69
High Capacity Emergency Lights...............................................................................70
LED Exit Signs........................................................................................................................ 71
Tandem Units..........................................................................................................72
Diecast LED Exit Signs........................................................................................................... 73
Recessed Mounting Edge-Lit LED Exit Signs....................................................................... 74
Remote Fixtures, Accessories & General Information
Inverter Power
Systems
Remote Heads and Fixtures . .................................................................................................76 to 78
Lamp Selector Guide ....................................................................................................................... 79
Voltage Drop Tables ....................................................................................................................... 80
Unit Accessories . .............................................................................................................................................81
National Electric Code ............................................................................................................................. 82, 83
NFPA 101 Life Safety Code . ................................................................................................................... 84, 85
Limited Warranty ............................................................................................................................ 86
Inverter Power Systems
Synchron Series Single-Phase Inverters ......................................................................................... 88 to 91
Spectron LSN Series Single-Phase Inverters ................................................................................92 to 101
Trident Series Three-Phase Inverters ...................................................................................................... 103 to 106
Auxiliary Transfer Switching Device ...................................................................................................................... 107
The following guide provides a fast, easy method of selecting
products for most applications. Refer to catalog pages for
additional product and ordering information.
Emergency Lighting Units
Catalog
Page
Number(s) Product Series
14, 15
LiteScape™ Series
Commercial
Units
16
EZ-2™ Series
Commercial
Units
17
LZ Series
Low-Profile
Halogen Lamp
Model
Number
Unit
Voltage
Watts
For
11/2 Hrs.
Battery
Type
Power Warranty
Consumption
Battery
(Max.)(1)
Equipment Full/Pro-Rata
LSC
LSCN
LSCI
LSCNI
GUARANTEED
CODE-COMPLIANCE
6
6
6
6
20
20
20
20
Lead-Calcium
Nickel-Cadmium
Lead-Calcium
Nickel-Cadmium
2 Watts
2 Watts
2 Watts
2 Watts
1 Years
1 Years
5 Years
5 Years
EZ-2
EZ-2V
EZ-2I
4
4
6
10.8
10.8
14.4
Lead-Calcium
“
“
15 Watts
15 Watts
15 Watts
3 Years 3/3 Years
3 Years 3/3 Years
5 Years 5/5 Years
Damp Location Model
EZ-2D
4
10.8
Lead-Calcium
15 Watts
3 Years
LZ2, LZ2D
LZ15
6
6
10
15
Lead-Calcium
”
3.5 Watts
”
1 Year 1/5 Years
”
”
Standard Models
LZ30
LZ35-12V
LZ65
LZ65-12V
LZ20N
LZ25N-12V
6
12
6
12
6
12
30
35
65
65
20
25
Lead-Calcium 14 Watts
”
”
”
”
”
”
Nickel-Cadmium 11.2 Watts
”
”
1 Year 1/5 Years
”
”
”
”
”
”
3 Years
1/9
”
”
Damp Location Models
LZ25D
LZ30D-12V
LZ55D
LZ55D-12V
LZ15ND
LZ20ND-12V
6
12
6
12
6
12
25
30
55
55
15
20
Lead-Calcium 14 Watts
”
”
”
”
”
”
Nickel-Cadmium 11.2 Watts
”
”
1 Year 1/5 Years
”
”
”
”
”
”
3 Years
1/9
”
”
6, 12
6, 12
—
—
—
—
—
—
Standard Models
LM2
LM16
LM33
LM40
LM66
LM80
LM130
LM40-12V
LM66-12V
LM80-12V
LM130-12V
6
6
6
6
6
6
6
12
12
12
12
14.4
16
33
40
66
80
130
40
66
80
130
Lead-Calcium
“
“
“
“
“
“
“
“
“
“
15 Watts
“
“
“
“
“
“
“
“
“
“
1 Year 1/5 Years
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Damp Location Models
LM28D
LM34D
LM56D
LM68D
LM112D
LM34D-12V
LM56D-12V
LM68D-12V
LM112D-12V
6
6
6
6
6
12
12
12
12
28
34
56
68
112
34
56
68
112
Lead-Calcium
“
“
“
“
“
“
“
“
15 Watts
“
“
“
“
“
“
“
“
1 Year 1/5 Years
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1/5 Years
1/9 Years
2/4 Years
2/4 Years
3/3 Year
Units
18, 19
LZ Series
High
Capacity
Halogen Lamp
Units
• Choice of battery types
• 6- and 12-volt models
• Capacities up to
65 watts
Remote Lighting Fixtures
Single Lamp Models
Tandem Lamp Models
20, 21
LM Series
Compact,
Traditional
Design Units
• Rugged metal housing
• 6- and 12-volt models
• Capacities up to 130
watts
• Lighting heads may be
top or side mounted
1 Year
1 Year
—
—
(1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power
consumption ratings on specific models.
Quick Selector Guide
Emergency Lighting Units
Catalog
Page
Number(s) Product Series
Model
Number
Unit
Voltage
Watts
For
11/2 Hrs.
20, 21
LM Series
Special
Application
NiCad Battery Models
14.4
Models
LM15N
6
LM30N
6
30
LM50N
6
50
LM50N-12V
12
50
LM100N-12V
12
100
• Rugged metal housing
• 6- and 12-volt models
• Capacities up to
100 watts
Battery
Type
Power Warranty
Consumption
Battery
(Max.)(1)
Equipment Full/Pro-Rata
Nickel-Cadmium
“
“
“
“
15 Watts
“
“
“
“
3 Years 1/9 Years
“
“
“
“
“
“
“
City of Chicago Models
LM24CH
LM36CH
LM36CH-12V
6
6
12
24
36
36
Lead-Calcium
“
“
15 Watts
“
“
1 Year 1/5 Years
“
“
“
“
EZ-2R
EZ-2RI
6
6
10.8
14.4
Lead-Calcium
“
15 Watts
15 Watts
3 Years 3/3 Years
5 Years 5/5 Years
TG15
TG30
TG50-12V
TG15N
TG30N
TG50N-12V
6
6
12
6
6
12
15
30
50
15
30
50
Lead-Calcium
”
”
Nickel-Cadmium
”
”
15 Watts
75 Watts
”
15 Watts
75 Watts
”
3 Years 3/3 Years
”
”
”
”
3 Years 1/9 Years
”
”
”
”
EXT-122-EM-K
6
8
Lead-Calcium
15 Watts
1 Year 1/5 Years
25
LITE2™ Series
Square
Units
urface, semi-recessed
• Sand
fully-recessed models
EDS
EDS-2
ERS
ERS-3
ERS-2-2
ESS-I
ESS-I-2
ERS-I
ERS-3I
ERS-2I-2
6
6
6
6
6
6
6
6
6
6
10
14.4
20
30
30
10
14.4
20
30
30
Lead-Calcium
”
”
”
”
Lead-Calcium
”
”
”
”
12 Watts
”
”
”
”
12 Watts
”
”
”
”
3 Years 3/3 Years
”
”
”
”
”
”
”
”
5 Years 5/5 Years
”
”
”
”
”
”
”
”
26
DELITE® Series
Cylinder
Units
ESC-2-0
6
12
Lead-Calcium
15 Watts
1 Years 1/5 Years
N4X2
N4X4
N4X7
N4X14
6
6
6
6
15.6
31.2
50.4
100
Lead-Calcium
”
”
”
75 Watts
”
”
”
3 Years 3/3 Years
”
”
”
”
”
”
N4X7-12V
N4X14-12V
12
12
50.4
100
”
”
”
”
• Lighting heads may be
top or side mounted
• Chicago Models
22
EZ-2R™ Series
Recessed
Mounting
Units
• Ceiling or wall mount
23
T-Grid™ Series
Recessed
Troffer
Units
• Suspended ceiling mount
24
EXT™ Series
Recessed
Gimbal
Unit
27
N4X Series
Sealed, Harsh
Environment
Unit
• Dust-tight, moisture
and corrosion resistant
”
”
”
”
(1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power
consumption ratings on specific models.
Emergency Lighting Units
Catalog
Page
Number(s) Product Series
28, 29
AS Series
Traditional
Model
Number
AS-80
AS-130
Voltage
6
6
AS-180-12V
AS-270--12V
AS-360-12V
12
12
12
180
270
360
”
”
”
”
”
”
”
”
”
”
”
”
• Maintenance-free
batteries
AS-180-24V
AS-270-24V
AS-360-24V
24
24
24
180
270
360
”
”
”
”
”
”
”
”
”
”
”
”
28, 29
ALC-X/EDC-X Series
Traditional
Units
ALC-X-30
ALC-X-60
ALC-X-100
6
6
6
78
144
162
Wet-Cell
Lead-Calcium
”
75 Watts
”
”
12EDC-X-36S
12EDC-X-60S
12EDC-X-120S
12
12
12
200
240
350
”
”
”
”
”
”
AS-75
AS-145
AS-210
6
6
6
75
110
145
Wet-Cell
Nickel-Cadmium
”
75 Watts
”
”
• Longest life,
12EDN-10S
12EDN-18S
12EDN-30S
12
12
12
48
100
150
”
”
”
”
”
”
”
”
”
”
”
”
30, 31
IPS Series
NEC Class I,
C1D2-6V36
C1D2-6V72
6
6
36
72
Pure-Lead
“
25 Watts
“
3
“
3/3
“
• Suitable for
C1D2-12V36
C1D2-12V72
12
12
36
72
“
“
“
“
“
“
“
“
32, 33
XPB Series
ExplosionProof Units
XPB-75P
12XPB-75P
6
12
75
75
Pure-Lead
”
75 Watts
”
Units
• Wet-cell
lead-calcium batteries
28, 29
AS/EDN Series
Traditional
Units
wet locations
Watts
Power Warranty
For
Battery
Consumption
Battery
11/2 Hrs.
Type
(Max.)(1)
Equipment Full/Pro-Rata
80
Lead-Calcium 75 Watts
1 Year 1/5 Years
130
”
”
”
”
1 Year 1/9 Years
”
”
”
”
”
”
”
”
”
”
Note: 12EDC-X models supplied
without lighting heads.
wet-cell nickel-cadmium Note: 12EDN models supplied
batteries
without lighting heads.
Division 2
Units
Unit
1 Year 1/14 Years
”
”
”
”
3 Years 3/3 Years
”
”
• NEC Class I
and II operation
• Unit mounted and
remote fixtures
(1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power
consumption ratings on specific models.
Fluorescent Power Packs
Catalog
Page
Number(s) Product Series
34
LAMPAK® Series
Fluorescent
Packs
• Models
standard
for
fluorescent lamps
Model
Number
UFO-3AW
UFO-4W
UFO-5W
UFO-5AW
UFO-6W
UFO-6WI
UFO-6W-CLD
35
LAMPAK® Series
Fluorescent
Packs
UFO-7W
UFO-7WI
• High lumen output
models
Operates
Lamp
Type
Std. Fluor.
Std. Fluor.
Std. Fluor.
Std. Fluor.
Std. Fluor.
Std. Fluor.
Std. Fluor.
Rating
I n
Battery
Lumens
Type
350-450 Nickel-Cadmium
500-600
”
600-700
”
600-700
”
1100-1400
”
1100-1400
”
600-750
”
Std. Fluor. 1450-3500 Nickel-Cadmium
Std. Fluor. 1800-3500
“
Number Warranty
Of Lamps
Battery
Operated
Equipment Full/Pro-Rata
1
1 Year 1 Year
1
”
”
1
”
”
1 or 2
”
”
1 or 2
”
”
1 or 2
”
”
1 or 2
”
”
1 or 2
1 or 2
1 Year
“
1 Year
“
Quick Selector Guide
Fluorescent Power Packs
Catalog
Page
Number(s) Product Series
Model
Number
Operates
Lamp
Type
Rating
I n
Lumens
Battery
Type
Number Warranty
Of Lamps
Battery
Operated
Equipment Full/Pro-Rata
36
LAMPAK® Series
UFO-12W
Fluorescent
Packs
• For compact
fluorescent lamps
13 to 42W 300-750 Nickel-Cadmium
Compact
Fluor.
Lamps
1 or 2
1 Year
1 Year
LAMPAK® Series
UFO-LP1
37
Fluorescent
UFO-LP2
Packs
• For low-profile
T5 and T8 390-700 Nickel-Cadmium
Fluor.
650-1325
“
Lamps
1
1
1 Year
“
1 Year
“
38
LAMPAK® Series
HID Back-up
Ballast
• For metal-
Metal- 20 to 30% Nickel-Cadmium
Halide
Normal
“
HID Lamps Output
“
1
1
1
1 Year
“
“
1 Year
“
“
fluorescent fixtures
UFO-MH175
UFO-MH250
UFO-MH400
halide HID lamps
Exit Signs
Catalog
Page
Number(s) Product Series
AC Lamp
Type
AC Lamp
Wattage
DC Lamp
Type
Battery
Type
Power Warranty
Consumption
Battery
(Emerg. Max.)(1)
Equipment Full/Pro-Rata
40
LX Series
LED
Red – 2.6W
LED
Nickel-Cadmium
3.8 Watts
Thermoplastic
Green – 2.1W
LED Exit Signs
5 Years 1/9 Years
• All models
Damp Location Listed
41
DK Series
Incandescent
15W (2)
—
—
30 Watts
Thermoplastic
Incandescent
Exit Signs
3 Years
Excluding
AC Lamps
—
42, 43
LT Series
LED
Red – 2.6W
Halogen Lead-Calcium
5.0 Watts
5 Years 1/5 Years
Combination
Green
–
2.1W
and
Emergency
LED
Unit/LED Exit
Signs
• Damp Location
and Remote
Capacity models
44
NYXC Series
LED
Red –3.5W
LED
Lead-Calcium
7.0 Watts
Combination
Green
–
3.0W
Emergency
Unit/LED Exit
5 Years 1/5 Years
Signs
• Meets NY City
requirements
45
SMC Series
LED
Red – 2.6W
LED
Lead-Calcium
12 Watts
Combination
Green – 2.1W
Emergency
Unit/LED Exit
3 Years 1/5 Years
Signs
• Low-profile
side mounted
lighting heads
(1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power
consumption ratings on specific models.
Exit Signs
Catalog
Page
Number(s) Product Series
AC Lamp
Type
AC Lamp
Wattage
DC Lamp
Type
Battery
Type
Power Warranty
Consumption
Battery
(Emerg. Max.)(1)
Equipment Full/Pro-Rata
46, 47
Sempra® Series
LED
Red – 2.6W
LED
Nickel-Cadmium
3.8 Watts
Cast Aluminum
Green – 2.1W
LED Exit Signs
5 Years 1/9 Years
(Lifetime on
LED strip)
• Lifetime warranty
on LED lamp strip
Sempra® MR Series
LED
Red – 2.6W (2)
LED
Nickel-Cadmium
3.8 Watts
48, 49
Master/Remote
Green – 2.1W (2)
Cast Aluminum
LED Exit Signs
5 Years 1/9 Years
(Lifetime on
LED strip)
• Supplied as
2-sign sets
• Low-profile
Remote exit
• Lifetime warranty
on LED lamp strip
Sempra® SC Series
LED
Red – 2.6W
LED
Nickel-Cadmium
3.8 Watts
50, 51
Severe Conditions
Green – 2.1W
Cast Aluminum
LED Exit Signs
5 Years 1/9 Years
(Lifetime on
LED strip)
• Lifetime warranty
on LED lamp strip
52
Sempra® SCWL Series
LED
Red – 2.6W
LED
Nickel-Cadmium
3.8 Watts
Wet Location Cast
Green – 2.1W
Aluminum LED
Exit Signs
5 Years 1/9 Years
(Lifetime on
LED strip)
• Completely
sealed and
gasketed
• Lifetime warranty
on LED lamp strip
53
Sempra® SERS Series
LED
Red – 2.6W
LED
Nickel-Cadmium
3.8 Watts
Recessed Cast
Green – 2.1W
Aluminum LED
Exit Signs
5 Years 1/9 Years
(Lifetime on
LED strip)
• Lifetime warranty
on LED lamp strip
54
NYDC Series
LED
Cast Aluminum
LED Exit Signs
Red – 2.5W
LED
Nickel-Cadmium
3.5 Watts
5 Years 1/9 Years
• Meets NY City
requirements
55
LN4X Series
LED
Red – 2.6W
LED
Nickel-Cadmium
3.8 Watts
5 Years 1/9 Years
Wet Location
Green
–
2.1W
LED Exit Signs
• Suitable for damp, wet
and corrosive environments
Single Face
56
Freedom® LED Series
LED
LED
Lead-Acid
7.7 Watts
5 Years 1/4 Years
Red – 4.5W
Aluminum LED
Exit Signs
Green – 4.7W
Double Face
Red – 6.8W
Green – 6.7W
• Up to 12 hours of
emergency operation
• All models
Damp Location Listed
(1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power
consumption ratings on specific models.
10
Quick Selector Guide
Exit Signs
Catalog
Page
Number(s) Product Series
AC Lamp
Type
AC Lamp
Wattage
DC Lamp
Type
Battery
Type
Power Warranty
Consumption
Battery
(Emerg. Max.)(1)
Equipment Full/Pro-Rata
57
LEDS Series
LED
Red – 3.2W
LED
Nickel-Cadmium
3.3 Watts
Low-Profile
Green – 2.9W
Aluminum LED
Exit Signs
• All models
Damp Location Listed
NYX Series
LED
Red – 2.4W
LED
Nickel-Cadmium
3.5 Watts
58
New York City
LED Exit Signs
5 Years 1/9 Years
• Meets NY City
requirements
59
CMX Series
Chicago
Exit Signs
5 Years 1/9 Years
Incandescent Incand.– 20W (2) 5W (2)
Lead-Calcium
Incand.– 50W
or
Fluor.– 9W (2)
Fluor.– 28W
Fluorescent
5 Years 1/9 Years
• City of Chicago
approval No.
9823
Single Face
60, 61
LE Series
LED
LED
Nickel-Cadmium
3.8 Watts
Recessed Edge-Lit
Red – 2.2W
LED Exit Signs
Green – 2.5W
5 Years 1/9 Years
Double Face
Red – 3.4W
Green – 4.0W
• Choice of six
• Universal recess
rough-in kit
decorator finishes
Single Face
62, 63
LES Series
LED
—
—
Red – 2.2W
Surface Mount
Edge-Lit LED
Green – 2.5W
AC Exit Signs
• Wall-, ceiling- and
end-mount models
4.0 Watts
5 Years 1/9 Years
Double Face
Red – 3.4W
Green – 4.0W
• Choice of six
decorator finishes
NYE Series
LED
Red – 3.2W
LED
Nickel-Cadmium
4.0 Watts
64
NYC Recessed
Edge-Lit LED Exit
Signs
5 Years 1/9 Years
• Ceiling or wall
recess installation
• Meets NY City requirements
NYES Series
LED
Red – 3.2W
—
Nickel-Cadmium
65
NYC Surface
Mount Edge-
4.0 Watts
5 Years 1/9 Years
66
DEX Series
Incandescent
15W (2)
3.7W (2) Lead-Calcium
35 Watts
Special
Wording
Incandescent
Incandescent
Exit Signs
3 Years 1/5 Years
Excluding
AC Lamps
Lit LED Exit
Signs
• Wall-, ceiling- and
end-mount models
• Meets NY City requirements
(1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power
consumption ratings on specific models.
11
Quick Selector Guide
Emergency Lighting Products
Catalog
Page
Number(s) Product Series
68
SlimLite Series
Contemporary
Unit
69
CV Series
Designer
Units
• Standard and damp
location models
70
CVEC Series
Commercial
Units
• 6- and 12-volt
models
• Capacities up to 100
watts
• Lighting heads may be
top or side mounted
Catalog
Page
Number(s) Product Series
Model
Number
SL1, SL1-V
Unit
Voltage
Watts
For
11/2 Hrs.
Battery
Type
Power Warranty
Consumption
Battery
(Max.)(1)
Equipment Full/Pro-Rata
6
12
Lead-Calcium
3.5 Watts
1 Year 1/5 Years
Standard Models
CV2
CV3
CV5
Damp Location Models
CV2D
CV3D
CV5D
6
6
6
12
18
30
Lead-Calcium
”
“
4 Watts
”
14 Watts
1 Year 1/5 Years
”
”
“
“
6
6
6
12
18
30
Lead-Calcium
”
“
4 Watts
”
14 Watts
1 Year 1/5 Years
”
”
“
“
CVEC15
CVEC30
CVEC50
CVEC50-12V
CVEC100-12V
6
6
6
6
6
15
30
50
50
100
Lead-Calcium
”
“
”
“
9 Watts
9 Watts
20 Watts
14 Watts
39 Watts
1 Year 1/5 Years
”
”
“
“
”
”
“
“
AC Lamp
Type
AC Lamp
Wattage
DC Lamp
Type
Battery
Type
Power Warranty
Consumption
Battery
(Emerg. Max.)(1)
Equipment Full/Pro-Rata
71
CV3 Series
LED
Red – 2.6W
LED
Nickel-Cadmium
3.8 Watts
Thermoplastic
Green – 2.1W
LED Exit Signs
5 Years 1/9 Years
72
CVT Series
LED
Red – 2.6W
Halogen Lead-Calcium
5.0 Watts
Combination
Green
–
2.1W
and
Emergency
LED
Unit/LED Exit
Signs
5 Years 1/9 Years
Excluding
AC Lamps
73
CVD Series
LED
Cast Aluminum
LED Exit Signs
Red – 2.6W
LED
Nickel-Cadmium
3.8 Watts
Green – 2.1W
5 Years 1/9 Years
74
CVER Series
LED
Red –2.5W
LED
Nickel-Cadmium
5.2 Watts
Recessed
Green – 3.0W
Mount Edge
Lit LED Exit
Signs
5 Years 1/9 Years
(1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power
consumption ratings on specific models.
Inverter Power Systems
Catalog
Page
Number(s) Product Series
88 to 91
92 to 101
103 to 104
105 to 106
12
Synchron Series
Spectron LSN
Trident TRX Series
Trident TRN Series
System
Type
System
Output
Capacities
Single Phase 400 to 2100VA
Single Phase 1.0 to 17.5kVA
Three Phase 10 to 30kVA
Three Phase 30 to 130kVA
Emergency Lighting Units
LiteScape Series
EZ-2 Series
LZ Series
LZ (HC) Series
LM Series
EZ-2R Series
T-Grid Series
EXT Series
Lite2 Series
Delite Series
N4X Series
AS Series
IPS Series
XPB Series
Lampak Series
Guaranteed Code Compliant Emergency Lights................. 14,
15
Commercial Emergency Lights. ............................................... 16
Designer Emergency Lights.............................................................17
High Capacity Designer Emergency Lights......................... 18,
19
21
Recessed Emergency Lights.............................................................22
Recessed T-Grid Emergency Lights........................................... 23
Recessed Gimbal Emergency Light........................................... 24
Emergency Lighting Square Units. ..................................... 25
Emergency Lighting Cylinder Units.......................................... 26
Harsh Environment Emergency Lights...................................... 27
Industrial Emergency Lights............................................. 28, 29
Wet Location Emergency Lights. ...................................... 30, 31
Explosion-Proof Emergency Lights.................................... 32, 33
Fluorescent Power Packs.............................................. 34 to 38
High Capacity Emergency Lights....................................... 20,
13
LiteScape
Commercial Emergency Light
Features
• Factory guaranteed NFPA-101
code-compliant illumination
W
Field
adjustable 3 ft. x 40 ft. or
•
NE
6 ft. x 30 ft. egress illumination
patterns
• SurePath® technology delivers
bright, continuous illumination
• Low-profile silhouette
• Fast, easy installation
• High-output, 6 volt, 10-watt
halogen lamps
• Impact resistant, UV stable
polycarbonate construction
GUARANTEED CODE• Unit housing is paintable
COMPLIANT ILLUMINATION
• Lead-acid or nickel-cadmium
rdering nformationbattery models
O
I
20W
• Universal 120/277VAC operation
• AC lockout
• Available with Spectron®
self-testing/self-diagnostic
electronics with time-delay relay
(TDR) standard
• Low-voltage battery disconnect
• Test switch and AC-On indicator
• Temperature range:
Lead-acid models = 20°C to 30°C
(68°F to 86°F)
Nickel-Cadmium models = 0°C to 40°C
(32°F to 104°F)
• UL 924 Listed (Emergency Lighting)
• UL Damp Location Listed
(Nickel-Cadmium models only)
Ordering Information
Nickel-Cadmium
Standard Model
Nickel-Cadmium Model
Spectron Self-Testing Model Spectron Self-Testing Model
ptions
(Add suffix to
model)
ccessories
(Order
Separately)
LSC
LSCN
LSCI
LSCNI
O
A
Options
-24K
-AA
(Add
suffix to model)
220/240VAC, 60Hz. operation
Audible alarm (1)
(1) For use with LSCI and LSCNI self-testing/self-diagnostic
models only.
Patented reflector design
produces bright, evenly illuminated
“SurePath™” egress lighting pattern
SurePathTM Technology
The heart of LiteScape’s SurePath technology is the patent pending reflector design created exclusively for Dual-Lite by
Breault Research Organization, the company selected to correct the optics for the Hubble space telescope. This unique
reflector design coupled with the unit’s two high-output, 10-watt halogen lamps provide an incredibly bright and
evenly distributed illumination pattern. Additionally, a user-selectable reflector adjustment allows a choice of the 3’ or
6’ wide SurePath illumination patterns. The long, broad and even nature of the SurePath illumination pattern makes it
the optimum method of lighting interior paths of egress during emergency conditions.
Dimensions
81/2”
Housing is field paintable
to match wall decor.
11”
14
1 2”
3/
LiteScape
The LiteScape Performance Guarantee
Dual-Lite guarantees the LiteScape unit will fully meet the 2003 edition of the NFPA 101
Life Safety Code emergency lighting requirements by providing an average of one footcandle of
illumination along the path of egress as defined in the illustration below.
Center to Center Mounting Information
7.5 ft.
3-Foot Wide Standard Illumination Path Setting = 40 Foot Centers
6-Foot Wide Optional Illumination Path Setting = 30 Foot Centers
NOTE:
The LiteScape unit must be installed per factory instructions provided
and properly maintained. In addition, the pathway to be illuminated
must meet the minimum surface reflectance values shown at right to
qualify for guaranteed illumination performance.
Minimum Reflectance Values Required:
Ceiling: 80% Walls: 50% Floor: 20%
The LiteScape Performance Guarantee applies solely to units mounted 7.5 feet above the floor surface. For information on lighting performance
at other mounting heights, refer to LiteScape Series Mounting Guide on the LiteScape product page in the Dual-Lite web site’s on-line catalog.
The LiteScape Performance Guarantee is subject to all conditions as outlined in the Product Warranty Statement on the Dual-Lite public web site
(www.dual-lite.com) and applies only to the installation’s initial emergency lighting inspection by the authority having jurisdiction.
Photometrics
3-Foot Standard Illumination Path Setting (40-Foot Mounting Centers)
6-Foot Optional Illumination Path Setting (30-Foot Mounting Centers)
1) Photometric illustrations based on data provided by Independent Testing Laboratories (ITL), Boulder, Colorado.
2) Photometrics shown based on 7.5-foot mounting height and minimum 80-50-20 reflectance values.
3) The white rectangular area in photometric illustrations represents normal center to center SurePath egress illumination pattern provided.
Independent Verification
The photometric data shown above was generated and verified by Independent Testing Laboratories (ITL) of Boulder,
Colorado. LiteScape IES photometric files can be downloaded from the LiteScape product page at www.dual-lite.com.
LiteScape illumination data has also been incorporated into the Hubbell LitePro® lighting design application software.
15
EZ-2
Commercial Emergency Lights
Features
An
Damp
Severe Conditions Product
• Easy to install
• Compact, low-profile design
• Flame-rated, UV-stable
thermoplastic housing
• Textured, bright white finish
• Universal mounting plate
• Glare-free, adjustable lampheads
• Maintenance-free battery
• Universal 120/277VAC operation
• Low power consumption
• Fully-automatic charger
• AC lockout
10.8W, 14.4W
• Low-voltage battery disconnect
• Transformer isolation protection
• Test switch and AC-On light
• Available with Spectron® selftesting/self-diagnostic electronics
with time-delay relay
(TDR) standard
• Damp location model available
• Temperature range: 20°C to 30°C
(68°F to 86°F)
Damp location EZ-2D: 0°C - 40°C
(32°F to 104°F)
• UL 924 Listed
(Damp Location Model EZ-2D)
Ordering Information
Standard Model
EZ-2
Options
-A21
Damp Location Model
EZ-2-D
(Add
Voltmeter Model
EZ-2-V
Spectron Self-Testing Model
EZ-2I
Accessories
suffix to model)
(Order Separately)
Vandal resistant shield
VRS
WGEL Wire guard
Auxiliary 2-conductor AC line cord (120V only)
Product Selector Guide
Electrical
Base
Catalog
Number
Output Watts
Output 1.5
2
3
4
Volts Hours Hours Hours Hours
AC Input
Standard Remote
Volts Amps Watts
Lamp Capability
EZ-2, EZ-2-D
6
10.8
--
--
- and EZ-2-V
120
.080
8.4
277
.030
8.8
120
.080
8.4
277
.030
8.8
14.4
--
--
-
EZ-2I*
6
5.4W
No
7.2W
No
* Includes Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard
Photometrics
Horizontal Isofootcandle Distribution
6 Volt, 5.4 Watt SBT Lamp
6 Volt, 7.2 Watt SBT Lamp
Dimensions
14” (35.5 cm)
5” (12.7 cm)
5” (12.7 cm)
16
Designer Emergency Lights
Features
• Easy to install
• Flame-rated, UV-stable
thermoplastic housing
• White or black finishes
• Slim, low-profile snap-together
design
• Standard and damp location
models
• Low profile, adjustable lampheads
• High-output halogen lamps
• Clear glass protective lamp lens
• Matching remote fixtures
• 120/277VAC operation standard
• Fully-automatic charger
LZ
10W
• Maintenance-free battery
• 90 minute operation
• Low-voltage battery disconnect
• Transformer isolation protection
• Test switch and AC-On light
• Available with Spectron® selftesting/self-diagnostic electronics
with time-delay relay
(TDR) standard
• Temperature range: 20°C to 30°C
(68°F to 86°F)
Damp location model: 10°C to 40°C
(50°F to 104°F)
• UL 924 Listed
Ordering Information
See Product Selector Guide below for available models
Matching remote
lighting head
Outdoor lighting
head
Options
(Add
Accessories
suffix to model)
I
-B
-V
-24K
-A21
Spectron self-testing/self-diagnostic electronics
Black finish
Voltmeter
220-240VAC, 60 Hz. operation
Auxiliary 2-conductor line cord (120V only) (1)
-A31
Auxiliary 3-conductor line cord (120V only) (2)
(3)
VRS
WGLZ
PMLZTW
PMLZTB
LZRSW0605
LZRSB0605
OMSSW0605
OMSSB0605
(1) Not for use with LZ15 model.
(2) For use with LZ15 model only.
(3) Not available with LZ2 model.
(Order Separately)
Vandal resistant shield
Wire guard
121/2” Pendant mounting kit - white
121/2” Pendant mounting kit - black
Matching remote lighting head - white
Matching remote lighting head - black
Outdoor lighting head - 6 Volt, 5 Watt
sealed beam type lamp - White finish
Outdoor lighting head - 6 Volt, 5 Watt
sealed beam type lamp - Black finish
Product Selector Guide
Base
Catalog
Numbers
Output
Volts
LZ2
LZ2D*
LZ15
6
6
6
Electrical
O
utput Watts
1.5
2
3
4
Hours
Hours
Hours
Hours
10
10
15
--
--
12
--
--
--
--
--
--
Standard
Lamp
Remote
Capability
5W Hal.
5W Hal.
5W Hal.
No
No
Yes
Photometrics
Dimensions
High-Output Halogen Lamp
Also available in black finish
Horizontal Isofootcandle Distribution
3 5/8” (9.2cm)
17
LZ
Designer Emergency Lights
Features
High Capacity
An
Severe Conditions Product Line
Damp
(Damp Location Models)
• Easy to install
• Capacities up to 65 watts
• 6- and 12-volt models
• Flame-rated, UV-stable
thermoplastic housing
• White or black finishes
• Snap-together design
• Standard and damp location
models
• Low profile lampheads
• High-output halogen lamps
• Clear glass protective lamp lens
• Matching remote fixtures
• 120/277VAC operation standard
15W to 65W
• Fully automatic charger
• Choice of maintenance-free battery
types
• Low-voltage battery disconnect
• Transformer isolation protection
• Test switch and AC-On light
• Available with Spectron® selftesting/self-diagnostic electronics
with time-delay relay
(TDR) standard
• Temperature range: 20°C to 30°C
(68°F to 86°F)
Damp location model: 10°C to 40°C
(50°F to 104°F)
• UL 924 Listed
Ordering Information
See Product Selector Guide for available models
Options
I
-B
-V
-10W
-0
-24K
-A31
(Add
Accessories
suffix to model)
Spectron self-testing/self-diagnostic electronics
Black finish
Voltmeter
10-watt halogen lamps (1)
Unit supplied without lampheads
220-240VAC, 60 Hz. operation
Auxiliary 3-conductor line cord (120V only)
(1) Available on units with capacities of 20 watts or more.
(Order Separately)
VRS Vandal resistant shield
WGEL Wire guard
LZRSW0605 Matching remote lighting head - white
LZRDSB0605 Matching remote lighting head - black
OMSSW0605 Outdoor lighting head - 6 Volt, 5 Watt
sealed beam type lamp - White finish
OMSSB0605 Outdoor lighting head - 6 Volt, 5 Watt
sealed beam type lamp - Black finish
OMSSW1205 Outdoor lighting head - 12 Volt, 5 Watt
sealed beam type lamp - White finish
OMSSB1205 Outdoor lighting head - 12 Volt, 5 Watt
sealed beam type lamp - Black finish
Outdoor
Lighting Heads
Matching
Remote Lighting
Heads
Also available in black finish
Matching Remote Fixtures
Photometrics
High-Output Halogen Lamp
Horizontal Isofootcandle Distribution
Standard 5W MR-16 Lamp
Optional 10W MR-16 Lamp
A complete line of 6- and 12-volt matching remote fixtures
in single and tandem lamp configurations is available for use
with LZ Series high-capacity units or any other 6- or 12-volt DC
emergency lighting remote power sources.
All remote fixtures are offered in black and white textured
finishes with a choice of 5- or 10-watt halogen lamps.
White
Black
18
Single
Tandem
Single
Tandem
Volts Watts
LZRSW0605 LZRDW0605
LZRSB0605 LZRDB0605
6
5
LZRSW0610 LZRDW0610
LZRSB0610 LZRDB0610
6
10
LZRSW1205 LZRDW1205
LZRSB1205 LZRDB1205
12
5
LZRSW1210 LZRDW1210
LZRSB1210 LZRDB1210
12
10
LZ
Product Selector Guide
High Capacity
Standard Models
Electrical
Base Catalog Numbers
LZ30
LZ35-12V
LZ65
LZ65-12V
LZ20N
LZ25N-12V
Output
Volts
Battery
Type
6
12
6
12
6
12
Lead-Calcium
Lead-Calcium
Lead-Calcium
Lead-Calcium
Nickel-Cadmium
Nickel-Cadmium
Output Watts
1.5
2
3
4
Standard
Hours Hours Hours Hours
Lamp
30
35
65
65
20
25
24
26
49
49
15
19
15
18
33
33
10
13
12
14
26
26
8
10
5W Hal.
5W Hal.
5W Hal.
5W Hal.
5W Hal.
5W Hal.
Remote
Capability
Yes
Yes
Yes
Yes
Yes
Yes
Damp Location Models
Electrical
Base Catalog Numbers
Output
Volts
LZ25D
LZ30D-12V
LZ55D
LZ55D-12V
LZ15ND
LZ20ND-12V
6
12
6
12
6
12
Battery
Type
Lead-Calcium
Lead-Calcium
Lead-Calcium
Lead-Calcium
Nickel-Cadmium
Nickel-Cadmium
Output Watts
1.5
2
3
4
Standard
Hours Hours Hours Hours
Lamp
25
30
55
55
15
20
19
24
42
42
11
15
13
15
28
28
8
10
10
12
22
22
6
8
5W Hal.
5W Hal.
5W Hal.
5W Hal.
5W Hal.
5W Hal.
Remote
Capability
Yes
Yes
Yes
Yes
Yes
Yes
Dimensions
5 1/8” (13 cm)
19
LM
High Capacity Emergency Lights
Features
• Easy to install
• Universal wall mounting pattern
• White, corrosion-resistant metal
housing and front-loading cover
• Maintenance-free battery
• 6- & 12-volt models
• Damp location models available
• Glare-free lampheads
• Lampheads may be top or
side mounted
An
• Available with 3 or 4 lampheads
• Available without lampheads
Severe Conditions Product Line
• Matching remote fixtures
(1) Damp Location
• 120/277VAC operation standard
Models Only
(1)
(220-240VAC, 60 Hz. optional)
(2)
Damp
Hot
Cold(2)
(2) NiCad Models Only
rdering
nformation
O
I
Example: LM130-3
14W to 130W
• Fully automatic, solid-state charger
• Low-voltage battery disconnect
• Transformer isolation protection
• Test switch and AC-On light
• Available with Spectron® selftesting/self-diagnostic electronics
with time-delay relay
(TDR) standard
• 90 minute operation
• Temperature range: 20°C to 30°C
(68°F to 86°F)
NiCad models:
20°C - 30°C
(68°F to 86°F)
Damp location models: 10°C to 40°C
(50°F to 104°F)
• UL 924 Listed
Ordering Information
See Product Selector Guide for available models
Options
Options
I
-V
-3
-4
-0
-A31
-A32
-24K
(Add
suffix to model)
(Add
suffix to model)
Accessories
Accessories
(Order Separately)
(Order Separately)
Spectron self-testing/self-diagnostic electronics( 1)(5) 40G Wire guard (Top mounted heads only)
Voltmeter
SRHSW Single matching remote head - white *
(1)(2)
Unit supplied with three lampheads
SRHDW Twin matching remote head - white *
(1)(2)
* Supplied with round mounting plate. Specify voltage and wattage when
Unit supplied with four lampheads
ordering. Example: SRHDW1212. See “Remote Heads and Fixtures”
section for available lamps.
Unit supplied without lampheads (1)(2)(3)
Auxiliary 3-conductor AC line cord (120V)
Auxiliary 3-conductor AC line cord (277V)
220-240VAC, 60Hz. operation (4)
(1) Not available with LM2 model.
(2) Not available with LM16 model.
(3) NOTE: Spectron models with over 80 watts of capacity require a minimum
load of 35 watts for accurate lamp failure indications.
(4) Not available on units with capacities over 80 watts for 1.5 hours.
SRH Series Matching
Remote Lighting Heads
(5) Spectron not available with Nickel-Cadmium battery models.
Optional Lamps
To order two nonstandard lamps on the fixture, suffix
catalog number. See “Remote Heads and Fixtures” section for available lamps. Example: LM33-SRHSW0612.
Dimensions
F
E
C
Photometrics
B
Horizontal Isofootcandle Distribution
6 Volt, 7.2 Watt SBT Lamp
D
12 Volt, 7.2 Watt SBT Lamp
Enclosure
Style A
20
7
A
B
C
D E
3
1
1
F
3
1
3 /8”
5 /4” 11 /2” 13 /2” 15 /4”
25”
9.8 cm 14.6 cm 29.3 cm 34.3 cm 40.0 cm 63.5 cm
2
4 3/4”
7 3/4” 13 1/2” 15 3/4”
18”
27 1/4”
12.1 cm 19.7 cm 34.3 cm 40.0 cm 45.7 cm 69.2 cm
LM
Product Selector Guide
Standard Models (1)
Catalog
Numbers
LM2
LM16
LM33
LM40
LM66
LM80
LM130
LM40-12V
LM66-12V
LM80-12V
LM130-12V
Enclosure
Style
Output
Volts
1
1
1
1
2
2
2
1
2
2
2
6
6
6
6
6
6
6
12
12
12
12
Electrical
Output Watts
1.5
2
3
4
Hours
Hours
Hours
Hours
14.4
16
33
40
66
80
130
40
66
80
130
—
—
25
31
51
62
101
31
51
62
101
—
—
17
21
35
43
70
21
35
43
70
—
—
13
16
27
33
54
16
27
33
54
Standard Remote
Lamp
Capability
7.2W
7.2W
7.2W
7.2W
7.2W
7.2W
7.2W
7.2W
7.2W
7.2W
7.2W
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Standard
Lamp
Remote
Capability
7.2W
7.2W
7.2W
7.2W
7.2W
No
Yes
Yes
Yes
Yes
Standard
Lamp
Remote
Capability
7.2W
7.2W
7.2W
7.2W
7.2W
7.2W
7.2W
7.2W
7.2W
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Standard
Lamp
Remote
Capability
12W
12W
12W
No
Yes
Yes
(1) Meets New York City Requirements
Nickel-Cadmium Models (1)
Catalog
Numbers
LM15N
LM30N
LM50N
LM50N-12V
LM100N-12V
Enclosure
Style
Output
Volts
1
1
1
1
1
6
6
6
12
12
Electrical
Output Watts
1.5
2
3
4
Hours
Hours
Hours
Hours
14.4
30
50
50
100
--
25
42
42
85
--
17
29
29
59
--
13
22
22
46
(1) Meets New York City Requirements
Damp Location Models (1)
Catalog
Numbers
LM28D
LM34D
LM56D
LM68D
LM112D
LM34D-12V
LM56D-12V
LM68D-12V
LM112D-12V
Enclosure
Style
Output
Volts
1
1
2
2
2
1
2
2
2
6
6
6
6
6
12
12
12
12
Electrical
Output Watts
1.5
2
3
4
Hours
Hours
Hours
Hours
28
34
56
68
112
34
56
68
112
21
26
43
53
87
26
43
53
87
15
18
30
36
60
18
30
36
60
11
14
23
28
47
14
23
28
47
(1) Meets New York City Requirements
All Metal City Of Chicago Models (2)
Catalog
Numbers
LM24CH
LM36CH
LM36CH-12V
Enclosure
Style
Output
Volts
1
1
1
6
6
12
Electrical
Output Watts
1.5
2
3
4
Hours
Hours
Hours
Hours
24
36
36
--
26
26
--
--
--
--
--
--
(2) 2000 Chicago Building Code compliant
21
EZ-2R
Recessed Emergency Lights
Features
• Easy installation in wall or
ceiling
• Compact, low-profile design
• All metal recessed housing
• Flame-rated, thermoplastic
lamp housing and
mounting plate
• Maintenance-free battery
• Glare-free lampheads
• 120/277VAC operation standard
• Fully automatic, solid-state
charger
10.8W, 14.4W
• Low-voltage battery disconnect
• Transformer isolation protection
• Test switch and AC-On light
• Available with Spectron®
self-testing/self-diagnostic
electronics with time-delay relay
(TDR) standard
• 90 minute operation
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL 924 Listed
Ordering Information
Standard Model
EZ-2R
Spectron Self-Testing Model
EZ-2RI
A
(Orderto
Separately
Occessories
ptions (Add suffix
model) )
Wall mounted EZ-2R unit
Accessories
(Order Separately)
F-CBM Troffer mounting kit (suspended ceilings)
WGEL Wire guard
EZ-2R suspended ceiling installation
using F-CBM accessory kit
Product Selector Guide
Electrical
Base
Catalog
Number
EZ-2R
Output
Volts
Output Watts
1.5
2
3
Hours
Hours
Hours
6
10.8
—
4
Hours
Standard
Lamp
Remote
Capability
—
5.4W
No
7.2W
No
—
14.4
—
—
—
EZ-2RI*
6
* Includes Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard
Dimensions
Photometrics
E
D
G
F
Horizontal Isofootcandle Distribution
6 Volt, 5.4 Watt SBT Lamp
A
5 3/4”
(14.6 cm)
B
11”
(27.9 cm)
C
3 7/8”
(9.8 cm)
D
7 3/4”
(19.7 cm)
E
9 1/8”
(23.2 cm)
F
5”
(12.7 cm)
G
6 1/8”
(15.6 cm)
C
6 Volt, 7.2 Watt SBT Lamp
A
B
Photometrics measured by independent testing laboratory
22
Recessed T-Grid Emergency Lights
Features
• Easy to install T-Grid lay-in
design
• Maintenance-free battery
• 6 and 12 volt models
• Heavy 20 gauge steel housing
• Standard white finish
• Standard with two glare-free
lampheads
• Dual voltage – 120V/277VAC
• Fully automatic, solid-state
charger
• Thermally compensated charger
• Regulated charge voltage
T-Grid
15W to 50W
• Automatic low voltage disconnect
• Reverse polarity protection
• Filtered charger output
• Short circuit protection
• AC lockout
• Test switch and AC-On light
• Available with Spectron®
self-testing/self-diagnostic
electronics with time-delay relay
(TDR) standard
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL 924 Listed
Ordering Information
Standard Models
NiCad Battery Models
Options
I
-V
-3
-0
(Add
TG15
TG15N
TG30
TG50-12V
TG30N TG50N-12V
Accessories
suffix to model)
(Order Separately)
SRHSW Matching remote head - single *
SRHDW Matching remote head - twin *
(1)
Spectron self-testing electronics
Voltmeter
Unit supplied with three lighting heads (2)
Unit supplied with no lighting heads
* Supplied with round mounting plate. Specify voltage and wattage
when ordering.
Example: SRHSW1212. See “Remote Heads and Fixtures” section for
available lamps.
(1) Spectron not available with NiCad battery models.
(2) Not available on TG15 and TG15N models.
SRH Series
Matching Remote
Lighting Heads
Optional Lamps
To order two nonstandard lamps on the fixture, suffix
catalog number. See “Remote Heads and Fixtures” section for available lamps. Example: TG30-SRHSW0612.
Product Selector Guide
Electrical
NiCad
Output Watts
Standard Battery Output 1.5
2
3
4
Models Models Volts Hours Hours Hours Hours
TG15
TG15N
6
15
11
8
6
TG30
TG30N
6
30
22
15
12
TG50-12V TG50N-12V
12
50
38
25
20
AC Input*
Volts
Amps
Watts
120
277
120
277
120
277
.064 (.070)
.029 (.032)
.064 (.114)
.029 (.051)
.120 (.250)
.051 (.108)
7.0 (7.6)
7.4 (8.0)
7.0 (12.3)
7.4 (12.7)
12.6 (27.0)
12.9 (26.9)
Standard Remote
Lamp Capability
7.2W
No
7.2W
Yes
7.2W
Yes
* AC Input figures in parenthesis are for NiCad battery models.
Photometrics
Dimensions
233/4”
(9.5 cm)
3 3/4”
Horizontal Isofootcandle Distribution
6 Volt, 7.2 Watt SBT Lamp
12 Volt, 7.2 Watt SBT Lamp
(60.3 cm)
7 1/4”
(18.4 cm)
51/4”
(13.3 cm)
23
EXT
Recessed Gimbal Emergency Light
Features
• Easy recessed installation in
suspended ceilings
• Built-in hanger bar
• Compact, low-profile design
• All metal housing and
gimbal assembly
• Ceiling white trim ring
• Lamp adjusts in two planes to 26˚
• High-output, 8 watt halogen
lamphead
• Maintenance-free battery
8W
• 120/277VAC operation standard
• Fully automatic, solid-state
charger
• Low-voltage battery disconnect
• Transformer isolation protection
• Test switch and AC-On light
• 90 minute operation
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL 924 Listed
Ordering Information
EXT-122-EM-K
Aptions
ccessories
(Order
Separately
O
(Add suffix
to
model) )
Accessories
(Order Separately)
WGLX Wire guard
EXT-122-EM-K unit shown installed
using built-in hanger bars
Product Selector Guide
Electrical
Base
Catalog
Numbers
Output
Volts
EXT-122-EM-K
6
Output Watts
1.5
2
3
Hours
Hours
Hours
8
—
4
Hours
Standard
Lamp
Remote
Capability
—
8W Hal.
No
—
Dimensions
6 1/8” (16.5 cm) Diameter
1
24 14” (
/2” 35.5
(62
7 1/2”
.2
(19.0 cm)
Photometrics
Horizontal Isofootcandle Distribution
(17
(m
(m in.)
ax
.)
7”
.7
6 Volt, 8 Watt Halogen SBT Lamp
cm
)
cm
)
cm
)
1 /2”
)
10 .6 cm
8 1/2”
(21.6 cm)
24
(26
Emergency Lighting Square Units
Features
Lite2
10W to 30W
• 120/277VAC operation standard
• Fully automatic, solid-state charger
• Low-voltage battery disconnect
• Transformer isolation protection
• Test switch and AC-On light
• Available with Spectron® self-testing/
self-diagnostic electronics with timedelay relay (TDR) standard
• 90 minute operation
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL 924 Listed
• Easy to install
• Matte-white frame and satinblack housing
• Available in single and twin
lamp models
• Maintenance-free battery
• Prismatic lens for uniform
illumination
• Polished alzak reflector
• Remote capability (ERS models
only)
• Matching remote fixtures
Ordering Information
Standard Models
Spectron Self-Testing Models
EDS
ERS Single lamp unit
ERS-2-2 Twin lamp unit
ERS-3 Single lamp unit
ptions (Add suffix to model)
Single lamp unit
O
Options
(Add
EDS-2
Twin lamp unit
ESS-I Single lamp unit
ERS-I Single lamp unit
ERS-3I Single lamp unit
Accessories
Accessories
suffix to model)
Voltmeter *
Fully recessed option
-V
-FRM
ESS-I-2 Twin lamp unit
ERS-2I-2 Twin lamp unit
F-SRM
WG-MLT
RERS-1-0609
RERS-2-0607
* Not available with fully recessed models.
(Order Separately)
(Order Separately)
Semi-recessed mounting kit
Wire guard
Matching remote fixture - single lamp
Matching remote fixture - twin lamps
Product Selector Guide
Electrical
Catalog
Numbers
Output Watts
Output
1.5
2
3
Volts
Hours Hours Hours
4
Hours
No.
Lamps
Standard
Lamps
Remote
Capability
EDS, ESS-I*
6
10
—
—
—
1
9W
No
ERS, ERS-I*
6
20
10
—
—
1
9W
Yes
ERS-3, ERS-3I*
6
30
22
15
—
1
9W
Yes
EDS-2, ESS-I-2*
6
14.4
—
—
—
2
7.2W
No
ERS-2-2, ERS-2I-2*
6
30
22
15
—
2
7.2W
Yes
* Includes Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard
Dimensions
(Fully-Recessed)
4”
(10.1 cm)
Semi-recessed model
11 9/16” sq.
(29.4 cm)
(Semi-Recessed)
(Surface Mounted)
4”
2 1/4”
(10.1 cm)
Fully-recessed model
(5.7 cm)
9” sq.
(22.9 cm)
9” sq.
(22.9 cm)
25
Delite
Emergency Lighting Cylinder Units
Features
12W, 31W
• Low-voltage battery disconnect
• Transformer isolation protection
• Test switch and AC-On light
• 90 minute operation
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL 924 Listed
• Easy to install
• Attractive matte-white cylinders
on contrasting black swivel
• Brushed aluminum base plate
• Multidirectional swivel lighting
heads
• Maintenance-free battery
• Matching remote fixture
• 120/277VAC operation standard
• Fully automatic solid-state
charger
Ordering Information
ESC2-0
Options
(Add
Accessories
suffix to model)
(Order Separately)
Ceiling recess mounting kit
Wire guard
F-TMK
41G
Product Selector Guide
Base
Catalog
Numbers
Output
Volts
ESC2-0
6
Electrical
Output Watts
3
4
Hours
Hours
1.5
2
Hours
Hours
12
—
—
No.
Cyls.
Standard
Lamp(s)
Remote
Capability
2
6W Halogen
No
—
Dimensions
C
F
A
B
D
Photometrics
Horizontal Isofootcandle Distribution
6 Volt, 6 Watt Halogen SBT Lamp
10
10
Feet
Left
Feet
Left
LAMP
AXIS
0
IFC
0.5
0.3
26
IFC
Feet
Right
Feet
Right
10
LAMP
AXIS
0
0.1
0.2
0
10
20
30
40
50
Feet From Lamp (measured on axis)
60
E
Vertical Distribution
Horizontal Distribution
70
10
Unit Model
Number
0.5
ESC2-0
0.3
0.2
10”
0
10
20
A
0.1
Dimensions
B
C
D
4 3/4”
10 1/2”
8 1/2”
E
F
5”
22”
25.4 cm 12.0 cm 26.7 cm 21.6 cm 12.7 cm 55.9 cm
30
40
50
60
70
Dotted lines show heads
in maximum
horizontal position.
Feet From Lamp (measured on axis)
Harsh Environment Emergency Lights
Features
• Gasketed construction
• Low-voltage battery disconnect
• Corrosion resistant hardware
• Transformer isolation protection
• Charcoal grey thermoplastic case
• Test switch and AC-On light
• Available in 6- or 12-volt versions
• Maintenance-free battery
• Available with Spectron®
self-testing/self-diagnostic
electronics with time-delay relay
(TDR) standard
• Capacities up to 100W
• 90 minute operation
• Matching remote fixture
• Temperature range: 10°C to 40°C
(50°F to 104°F)
• Fully adjustable lampheads
• 120/277VAC operation standard
• Fully automatic, solid-state
charger
• UL 924 Listed
An
• UL 924 Damp Location Listed
Severe Conditions Product Line
Ordering Information
N4X2
N4X4
Options
N4X7
(Add
N4X7-12V
N4X14
N4X14-12V
(Order Separately)
A
(a) Supplied with mounting plate.
Specify voltage and wattage when ordering.
Example: GNXSB0618.
See “Remote Heads and Fixtures” section for
available lamps.
(1) Not available on N4X2 model.
Lamps With Optional Shatter Containment Feature
Protective lamp cover safely contains glass lamp fragments in the
event of accidental breakage in sensitive areas such as food preparation or hospitals. To order N4X unit with shatter containment option,
suffix the catalog number. See “Remote Heads and Fixtures” section
for available lamps (1). Example: N4X4-GNXSB0608-L.
Optional Lamps
To order two nonstandard lamps on the fixture,
suffix catalog number. See “Remote Heads and
Fixtures” section for available lamps. Example:
N4X4-GNXSB0612.
(1) Excludes 6V, 7.2W and 12V, 9W lamps.
Product Selector Guide
Damp(1)
40G Wire guard
GNXSB Matching remote head - single (a)
(a)
ccessories
(O
rder
Separately
)
GNXDB
Matching remote
head
- twin
O
Electrical
Base
Catalog
Numbers
N4X2
N4X4
N4X7
N4X7-12V
N4X14
N4X14-12V
Output
Volts
1.5
Hours
6
6
6
12
6
12
15
31
50
50
100
100
Output Watts
2
3
Hours
Hours
—
22
36
36
79
79
—
15
29
29
61
61
4
Hours
Standard
Lamps
Remote
Capability
—
—
22
22
44
44
7.2W
7.2W
7.2W
9W
7.2W
9W
No
Yes
Yes
Yes
Yes
Yes
Dimensions
5/8”
Diam.
Photometrics
Horizontal Isofootcandle Distribution
6 Volt, 7.2 Watt SBT Lamp
12 3/4” (32.4 cm)
13 5/8” (34.6 cm)
16 1/4” (41.3 cm)
Corrosive
Accessories
suffix to model)
I
Spectron self-testing/self-diagnostic electronics
-0
Unit supplied without lighting heads (1)
(1)
(Add
to head
model
)
-1 ptions
Unit supplied
withsuffix
one lighting
-A31
Auxiliary 3-conductor AC line cord (120V)
-A32
Auxiliary 3-conductor AC line cord (277V)
N4X
15W to 100W
6”
10 1/4”
12 Volt, 9 Watt SBT Lamp
4 7/8”
11” Max.
27
AS
Industrial Emergency Lights
Features
• Easy to install
• NEMA 1 steel cabinet with dark
brown enamel finish
• 1/2” and 3/4” wiring KOs
provided
• Wet-cell and maintenance-free
battery models
• 6-, 12- and 24-volt models
• 12- and 24-volt models allow
longer wiring runs
• Glare-free lampheads
• Available with third lamphead
• Available without lampheads
• Matching remote fixtures
75W to 360W
• 120/277VAC operation standard
• Fully automatic, solid-state charger
• Low-voltage battery disconnect
• Transformer isolation protection
• Test switch and AC-On light
• Available with Spectron®
self-testing/self-diagnostic
electronics with time-delay relay
(TDR) standard
• 90 minute operation
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL 924 Listed
Ordering Information
See Product Selector Guide for available models
SRH Series
Matching Remote
Lighting Head
Options
I
-V
-C
-0
-1
-2
-3
-A31
-A32
(Add
Accessories
suffix to model)
Spectron self-testing/self-diagnostic electronics
Voltmeter
Ammeter (1)
Unit supplied without lampheads
Unit supplied with one lamphead
Unit supplied with two lampheads (2)
Unit supplied with three lampheads
Auxiliary 3-conductor AC line cord (120V)
Auxiliary 3-conductor AC line cord (277V)
(1) Not available with all models. Consult factory.
(2) Available for use with 12EDC
and 12EDN models only. All other
models are supplied standard with
two lampheads.
Photometrics
(1)
WB-6
6000
L-6
L-12-S
40G
41G
SRHSB
SRHDB
(Order Separately)
Wall mounting hanger bracket (all models)
Heavy-duty mounting shelf (Enclosure 1
models)
Mounting shelf (Enclosure 1 models)
Mounting shelf (Enclosure 2 models)
Wire guard (Enclosure 1 models)
Wire guard (Enclosure 2 models)
Matching remote lighting head - single *
Matching remote lighting head - twin *
* Supplied with round mounting plate. Specify voltage and wattage
when ordering. Example: SRHSB0612. See “Remote Heads and
Fixtures” section for available lamps.
Optional Lamps
To order two nonstandard lamps on the fixture, suffix
catalog number. See “Remote Heads and Fixtures” section for available lamps. Example: AS130-SRHSB0612.
Dimensions
Horizontal Isofootcandle Distribution
6 Volt, 7.2 Watt SBT Lamp
12 Volt, 7.2 Watt SBT Lamp
D
C
6 Volt, 25 Watt SB Lamp
24Volt, 7.2Watt SB Lamp
B
A
Enclosure Enclosure
Style
Ga.
A
B
14”
8”
111/2” 18 3/4”
8”
111/2” 18 3/4”
1
20 Ga. (.036”) 35.5 cm
16”
2
20 Ga. (.036”) 40.6
cm
28
C
D
20.3 cm 29.2 cm 47.6 cm
20.3 cm 29.2 cm 47.6 cm
AS
Product Selector Guide
Maintenance-Free Battery Models
Base
Catalog
Numbers
Electrical
Enclosure
Style
Output
Volts
AS80
1
6
80
62
AS130
1
6
130
AS180-12V
1
12
AS270-12V
1
AS360-12V
1.5
Hours
Output Watts
2
3
Hours
Hours
4
Hours
Standard
Lamp
Remote
Capability
43
33
7.2W
Yes
101
70
54
7.2W
Yes
180
144
112
77
7.2W
Yes
12
270
227
168
116
7.2W
Yes
1
12
360
288
230
172
7.2W
Yes
AS180-24V
1
24
180
144
112
77
9.0W
Yes
AS270-24V
1
24
270
227
168
116
9.0W
Yes
AS360-24V
1
24
360
288
230
172
9.0W
Yes
4
Hours
Standard
Lamp
Remote
Capability
NOTE: Batteries for all Maintenance-Free models are shipped with the units.
Wet-Cell Lead-Calcium Battery Models
Base
Catalog
Numbers
Electrical
Enclosure
Style
Output
Volts
ALC-X-30
1
6
78
57
42
28
25W
Yes
ALC-X-60
1
6
144
108
81
54
25W
Yes
ALC-X-100
1
6
162
121
91
61
25W
Yes
12EDC-X-36S
2
12
200
165
125
86
(*)
Yes
12EDC-X-60S
2
12
240
192
153
115
(*)
Yes
12EDC-X-120S
2
12
350
280
224
168
(*)
Yes
4
Hours
Standard
Lamp
Remote
Capability
1.5
Hours
Output Watts
2
3
Hours
Hours
(*) These models supplied standard without lampheads
NOTE: Batteries for all Wet-Cell Lead-Calcium models are shipped separately.
Wet-Cell Nickel-Cadmium Battery Models
Base
Catalog
Numbers
Electrical
Enclosure
Style
Output
Volts
AS75
1
6
75
57
42
28
25W
Yes
AS145
1
6
110
85
59
46
25W
Yes
AS210
1
6
145
112
84
54
25W
Yes
12EDN-10S
2
12
48
38
25
20
(*)
Yes
12EDN-18S
2
12
100
76
54
44
(*)
Yes
12EDN-30S
2
12
150
115
86
57
(*)
Yes
1.5
Hours
Output Watts
2
3
Hours
Hours
(*) These models supplied standard without lampheads
NOTE: Batteries for all Wet-Cell Nickel-Cadmium models are shipped separately.
29
IPS
Wet Location Emergency Lights
Features
• Suitable for wet or damp
applications
• Designed for Class I, Div 2 locations
• Compact, factory assembled system
• Sealed and gasketed NEMA 3R
construction
• Corrosion resistant hardware
• Black thermoplastic case with
battery vent
• Available in 6- or 12-volt versions
• Fully adjustable 8 watt halogen
sealed beam lampheads
• Maintenance-free battery
• Matching remote fixtures
An
Severe Conditions Product Line
36W, 72W
• 120/220/240/277VAC operation
standard
• Fully automatic, solid-state charger
• Automatic 15-minute retransfer
delay
• Low-voltage battery disconnect
• Transformer isolation protection
• Test switch and AC-On light
• T-6 100°C (212°F) lamphead rating
• 120 minute operation
• Temperature range: 0°C to 40°C
(32°F to 104°F)
• UL Listed to Standard 924 and
Standard 844 (Hazardous Locations)
Ordering
Information
844
NEMA 3R Enclosures (NEMA Standards 250)
Hazardous
Damp
Corrosive
Wet
Enclosures are intended for outdoor use primarily to provide a degree of
protection against falling rain and sleet, undamaged by the formation of
ice on the enclosure.
Ordering Information
Options
(Add suffixC1D2-12V36
to model) C1D2-12V72 Accessories
C1D2-6V36
C1D2-6V72
(Order Separately)
Options
-0
-1
-12
(Add
suffix to model)
Unit supplied without lampheads
Unit supplied with one lamphead
Unit supplied with 12 watt halogen lamps
Product Selector Guide
Base
Catalog
Numbers
C1D2-6V36
C1D2-6V72
C1D2-12V36
C1D2-12V72
Electrical
Output
Volts
2
Hours
6
6
12
12
36
72
36
72
Output Watts
3
Hours
24
50
24
50
Photometrics
Horizontal Isofootcandle Dist.
6 Volt, 8 Watt Halogen SB Lamp
Photometrics measured by independent
testing laboratory
30
12 Volt, 8 Watt Halogen SB Lamp
4
Hours
Standard
Lamps
Remote
Capability
19
39
19
39
8W Hal.
8W Hal.
8W Hal.
8W Hal.
Yes
Yes
Yes
Yes
Accessories
IPS
(Order Separately)
Remote Lighting Heads
Lamp
Volts Watts
Matching single and twin head
remote lighting fixtures
Single-Head Model Numbers
Hub Left Side
Hub Right Side
Hub Both Sides
6
8
C1D2R-6V8W
C1D2R-6V8WR
C1D2R-6V8WF
6
12
C1D2R-6V12W
C1D2R-6V12WR
C1D2R-6V12WF
12
8
C1D2R-12V8W
C1D2R-12V8WR
C1D2R-12V8WF
12
12
C1D2R-12V12W
C1D2R-12V12WR
C1D2R-12V12WF
Lamps
Volts Watts
Twin-Head Model Numbers
Hub Left Side
Hub Right Side
Hub Both Sides
6
8
C1D2TR-6V8W
C1D2TR-6V8WR
C1D2TR-6V8WF
6
12
C1D2TR-6V12W
C1D2TR-6V12WR
C1D2TR-6V12WF
12
8
C1D2TR-12V8W
C1D2TR-12V8WR
C1D2TR-12V8WF
12
12
C1D2TR-12V12W
C1D2TR-12V12WR
C1D2TR-12V12WF
* PAR 36 Halogen sealed beam lamps.
Dimensions
11/2”
(3.8 cm)
1.9 cm
17”
(43.1 cm)
12 1/2”
(31.7 cm)
11 1/4”
(28.6 cm)
12”
(30.5 cm)
6 3/4”
(17.1 cm)
13 1/4”
(33.7 cm)
95/8”
9 5/8”
(24.4 cm)
Mounting holes
41/4”
7
227//88””
(7.3 cm)
7711//22”
(1981cm)
/8”
8 1/8”
(20.6 cm)
3
/4” Hub
1.9 cm
4 1/4”
(10.8 cm)
1111//44””
(3.25 cm)
4 /8”
5
4 /8”
(14.3 cm)
Mounting
holes
7
2 7/8”
2 /8”
(7.3 cm)
3
/4” Hub
1.9 cm
12”
12”
(30.5
cm)
125/8”
12 5/8”
(32.1 cm)
31
XPB
Explosion-Proof Emergency Lights
Features
• Suitable for Class I, Div. I & II
applications
• High-strength, copper-free
aluminum housing
• Quick access thread-on cover
• Test switch included
• AC-On indicator light
• Maintenance-free battery
• 6- and 12-volt models
An
Corrosive
Severe Conditions Product Line
75W
• Capacity for remote fixtures
• 120/277VAC operation standard
• Fully automatic, solid-state charger
• Low-voltage battery disconnect
• Transformer isolation protection
• Optional fixtures available for
a wide range of hazardous
environments
• 90 minute operation
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL Listed to Standard 924
and Standard 844 (Hazardous
Locations)
Ordering Information
Ordering Information
(Class I, Divisions I & II, Groups C through G)
Explosion-Proof
XPB-75P 12XPB-75P
Options
-TDR
(Add
Accessories
suffix to model)
(Order Separately)
15-minute retransfer delay (120VAC only)
Product Selector Guide
Electrical
Base
Output Watts
Output
1.5 2 3 4
Catalog
Numbers
Volts
Hours
Hours
Hours
Hours
XPB-75P
12XPB-75P
Standard
Lamp
Remote
Capability
6
75
57
42
28
(*)
Yes
12
75
57
42
28
(*)
Yes
(*) Unit is supplied without lighting fixtures. Unit must operate at least one lighting fixture (unit mounted or remote)
to meet UL Standard 924 requirements. See following page for explosion-proof lighting fixtures and accessories.
Dimensions
10 3/4”
12”
(27.3 cm)
6 3/16”
(30.5 cm)
(15.7 cm)
XPB-75P shown with EX-1CD
unit-mounted lighting fixtures
14 1/2”
(36.8 cm)
Depth = 8” (20.3 cm)
32
3”
(7.6 cm)
Depth = 5 9/16” (14.1 cm)
Explosion-Proof Fixtures (1)
Fixtures for direct mounting to XPB Series Unit
EX-1CD
All fittings required for unit mounting supplied standard. Up to three
fixtures may be connected (unit mounted and/or remote).
Catalog
Number
EX-1CD618
EX-1CD628
EX-1CD
Lamp
Lamp
Voltage Wattage
6
6
18
28
Catalog
Number
EX-1CD1218
EX-1CD1228
Lamp
Lamp
Voltage Wattage
12
12
18
28
Fixtures for remote mounting
REX1CDP*
Fixture for pendant mounting; one 1/2” hub, rigid or flexible mounting.
Catalog
Number
REX1CDP
Lamp
Lamp
Voltage Wattage
Catalog
Number
Lamp
Lamp
Voltage Wattage
REX1CDP618
6
18
REX1CDP1218
12
18
REX1CDP628
6
28
REX1CDP1228
12
28
REX1CDC*
Fixture for ceiling mounting; four 1/2” hubs, three close-up plugs.
Catalog
Number
REX1CDC
Lamp
Lamp
Voltage Wattage
Catalog
Number
Lamp
Lamp
Voltage Wattage
REX1CDC618
6
18
REX1CDC1218
12
18
REX1CDC628
6
28
REX1CDC1228
12
28
REX1CDW*
Fixture for wall mounting; four 1/2” hubs, three close-up plugs.
Catalog
Number
REX1CDW
Lamp
Lamp
Voltage Wattage
Catalog
Number
Lamp
Lamp
Voltage Wattage
REX1CDW618
6
18
REX1CDW1218
12
18
REX1CDW628
6
28
REX1CDW1228
12
28
REX1CDA*
Fixture for angled (15°) wall mounting; two 1/2” hubs, one close-up plug.
Catalog
Number
REX1CDA
Fixture Accessories
XWG
XWG
EX100CD
REX-SDR
REX-AR
REX1CDA618
REX1CDA628
Lamp
Lamp
Voltage Wattage
6
6
18
28
Catalog
Number
REX1CDA1218
REX1CDA1228
Lamp
Lamp
Voltage Wattage
12
18
12
28
* Fixtures shown with optional “XWG” globe guards.
(1) When connected to XPB emergency units, lighting fixtures will operate in the
“normally-off” mode.
EX100CD
REX-SDR
REX-AR
Aluminum (copper-free) globe guard. Protects fixture lens from accidental impact damage. Two-coat, baked
epoxy, medium-gray enamel finish.
Auxiliary housing with “EXIT” legend for “normally off” operation only. Housing constructed of 18-gauge
sheet metal; medium-gray enamel finish. Glass face with 6” high, 3/4” stroke red letters on white
background. (Lighting fixture not included).
Standard dome reflector. Steel, with white porcelain enamel finish.
Angled (30°) reflector. Steel, with white porcelain enamel finish.
33
Lampak
Fluorescent Power Packs
Features
UFO-3, 4, 5, 6
W
NE
An
Severe Conditions Product Line
Damp
• Battery case made of heavy 22gauge steel
• Reliable, high-frequency inverter
• Sealed nickel-cadmium battery
• Universal 120/277VAC operation
• Test switch and LED charge
indicator light supplied standard
• Provides 90 minutes of
emergency lighting
• Low power consumption
• Temperature range: 0°C to 50°C
(32°F to 122°F)
• UL 924 Listed (Emergency Lighting)
• UL 924 Damp Location Listed
• Compatible with electronic,
standard magnetic, energy
saving, and dimming AC ballasts
• Compatible with most standard
T8, T10 or T12, energy-saving or
rapid start, (4-pin) long compact
fluorescent lamp
• Easy installation with versatile
mounting capability inside of
ballast channel, on top of or
remote from fixture
• Operates one or two lamps in
emergency mode
• Can be used with switched or
unswitched lighting fixtures
Ordering Information
Standard Models
UFO-3AW, UFO-4W, UFO-5W, UFO-5AW, UFO-6W
Self-Testing Spectron Model
UFO-6WI
ptions (Add suffix to model)
O
Accessories
(Order Separately)
F-WC Wire bundle cover (1)
SPRTS Remote test switch/charge indicator
ccessories (Order Separately)
module (2)
A
(1) Encloses exposed wiring harness when power pack is externally
mounted on the lighting fixture. One required per fixture.
Extended Temperature Model*
UFO-6W-CLD
(2) Fits single-gang box.
* Extends temperature range to -20°C to 55°C (-4°F to 131°F)
Product Selector Guide
Catalog
Number
Output
Wattage
Initial
Lumens
Electrical
Number
of Lamps
Operated
UFO-3AW
UFO-4W
UFO-5W
UFO-5AW
UFO-6W, UFO-6WI
UFO-6W-CLD
9.6
14.4
14.4
14.4
24.0
24.0
350-450
500-600
600-700
600-700
1100-1400
Up to 1200
1
1
1
1 or 2
1 or 2
1 or 2
Base
Lamp
Sizes
Input
Wattage
2’-4’
2’-4’
2’-8’
2’-8’
2’-8’
2’-8’
3.5
3.5
3.5
3.5
4.0
4.0
Installation
Lampak UFO 3, 4, 5 and 6 emergency power
packs do not affect normal fixture operation and
may be used with either switched or unswitched
fixtures. UFO-3, 4, 5 and 6 packs may be installed
inside, on top of, or remote from the fixture. The
fluorescent pack may be remotely installed up to
half the distance from the lamp the AC
ballast manufacturer recommends, or up to 50
feet, whichever is less. UFO-3, 4, 5 and 6 packs are
not suitable for installation in heated air outlet
fixtures and wet or hazardous location fixtures.
Installation is not recommended with fixtures where
the ambient temperature may fall below 0°C (32°F ).
Dimensions
B
A
C
Model
34
A
B
C
UFO-3AW, 4W, 5W, 5AW
9 3/8” (23.8 cm) 11/2” (3.8 cm) 2 3/8” (6.0 cm)
UFO-6W, -6WI & -6-CLD
13 3/8” (33.9 cm) 1 1/2” (3.8 cm) 2 3/8” (6.0 cm)
Lampak
High Lumen Fluorescent Power Packs
Features
• Standard and Spectron self-testing/
self-diagnostic models offered.
• Compatible with electronic,
standard magnetic, energy
saving, and dimming AC ballasts
• Compatible with most standard
2 - 8 foot, T8, T9, T10 or T12 and
rapid-start (4-pin) long compact
fluorescent lamps
• Easy installation on top of or
remote from fixture
• Operates one or two lamps
depending on fixture
• Can be used with switched or
unswitched lighting fixtures
UFO-7
• Battery case made of 22-gauge steel
• Reliable, high-frequency inverter
• Premium sealed nickel-cadmium
battery
• Universal 120/277VAC operation
• Test switch and LED charge indicator
light supplied standard
• 90 minutes emergency operation
• Low power consumption
• Temperature range: 0°C to 40°C
(32°F to 104°F)
• UL 924 Listed (Emergency Lighting)
• UFO-7WI Model UL 924 Damp
Location Listed
W
NE
An
Severe Conditions Product Line
Ordering Information
UFO-7W (Standard Model)
UFO-7WI (Self-Testing Model)
Options
(Add
Damp
* UFO-7WI Model Only
Accessories
(Order Separately)
F-WC Wire bundle cover (1)
SPRTS Remote test switch/charge indicator
ccessories
(Order Separately)
module (2)
A
suffix to model)
(1) Encloses exposed wiring harness when power pack is externally
mounted on the lighting fixture. One required per fixture.
(2) Fits single-gang box.
Product Selector Guide
Catalog
Number
UFO-7W
UFO-7WI
Base
Output
Wattage
Initial
Lumens
Electrical
Number
of Lamps
Operated
Lamp
Sizes
Input
Wattage
57.6
57.6
1450-3500
1800-3500
1 or 2
1 or 2
2’-8’
2’-8’
8.0
8.0
Table 1 (Models UFO-7W, UFO-7WI)*
Lamp
Base Type
Diameter
Power
(Length)
No. of Lamps
Operated (Emerg.)
Single or
Bipin
4-Pin
(2G11)
17 - 40W (2’ to 4’)
40 - 215W (5’ to 8’)
18 - 39W
40 - 55W
1 or 2
1
1 or 2
1
4-Pin
(G24q, GX24q)
18 - 42W
1 or 2
(1”, 11/8”,11/4”,11/2”)
T8, T9, T10, T12
Long
Compact
Compact
* Partial listing of lamps operated
Table 2*
Lamp
Type
FO25, FBO24 T8
FO32, FBO31 T8
FO40 T8
FO96 T8
F40 T12, F40/U
F40 T12ES (34W)
F48 T12/HO
F96 T12
F96 T12/HO
F96 T12/VHO
Lumens
1 Lamp 2 Lamps
2250
2600
3000
3000
2400
-3000
-3000
3000
2700
2700
3000
-2800
-2900
-3300
--
Table 2* (Continued)
Lamp
Type
PL-L 24W, F27/24BX
Dulux L 27W
PL-L 36W, F39/36BX
Dulux L 39W
PL-T 42W/4P
PL-L 40W, F40/30BX
F50BX, Dulux L 55W
F28 2D/4P
F38 2D/4P
Lumens
1 Lamp 2 Lamps
1800
2300
2900
3500
3200
1800
3500
--
2050
1450
2800
2800
Installation
LAMPAK UFO-7W Series emergency power packs do not
affect normal fixture operation and may be used with
either switched or unswitched fixtures. UFO-7W Series
models may be installed on top of, or remote from the
fixture. The emergency ballast may be remotely installed
up to half the distance from the lamp the AC ballast
manufacturer recommends, or up to 50 feet, whichever
is less.
UFO-7W Series emergency power packs are not suitable
for installation in heated air outlet fixtures and wet or
hazardous location fixtures. Installation is not recommended with fixtures where the ambient temperature
may fall below 0°C (32°F ).
Dimensions
16.3”
1.7”
41.4cm
4.4cm
5.5”
13.8cm
* Partial listing of lamps operated.
Initial lumen output measured at 25°C
ambient temperature.
35
Lampak
Compact Fluorescent Power Packs
Features
UFO-12
W
NE
An
Severe Conditions Product Line
Damp
• Compatible with electronic,
standard magnetic, energy saving,
and dimming AC ballasts
• Compatible with most 13W to
42W rapid start, 4-pin compact
twin, quad or triple twin tube
fluorescent lamps
• Easy installation on top of or
remote from fixture
• Operates one or two lamps in
emergency mode
• Can be used with switched or
unswitched lighting fixtures
• Battery case made of heavy 22gauge steel
• Reliable, high-frequency
inverter
• Premium sealed nickel-cadmium
battery
• Universal 120/277VAC operation
• Test switch and LED charge
indicator light supplied standard
• 90 minute operation
• Low power consumption
• Temperature range: 0°C to 50°C
(32°F to 122°F)
• UL 924 Listed (Emergency Lighting)
• UL 924 Damp Location Listed
Ordering Information
UFO-12W
Accessories
Options
(Add
(Order Separately)
F-WC Wire bundle cover (1)
SPRTS Remote test switch/charge indicator
module (2)
ccessories
rder
eparately
)
(1) Encloses
exposed wiring harness(O
when
power S
pack
is externally
A
suffix to model)
mounted on the lighting fixture. One required per fixture.
(2) Fits single-gang box.
Product Selector Guide
Electrical
Base
Catalog
Number
UFO-12W
Ballast
Compat.
Number
Initial of Lamps
Lumens Operated
Magnetic,
See
See
Electronic,
Table 1
Table 1
Energy Saving
& Dimming
Lamp
Type
13W through 42W quad and
triple tube lamps without
G24q-2, G24q-3
integral starters (4-pin lamps)
GX24q-3, GX24q-2
Table 1*
Lamp
Type (4-Pin)
PL-T 42W/4P, Dulux T/E 42W
PL-T 32W/4P, Dulux T/E 32W
PL-T 26W/4P, Dulux T/E 26W, F26TBX/4P
PL-T 18W/4P, Dulux T/E 18W, F18TBX/4P
PL-C 26W/4P, Dulux D/E 26W, F26DBX/4P
PL-C 18W/4P, Dulux D/E 18W, F18DBX/4P
PL-C 13W/4P, Dulux D/E 13W, F13DBX/4P
PL-L 40W, Dulux L 40W, F40/30 BX/4P
PL-L 36W, Dulux L 39W, F39/36 BX/4P
PL-L 24W, Dulux L 27W, F27/24 BX/4P
PL-L 18W, Dulux L 18W, F18 BX
F3 82D/4P
FO25, FBO24 T8
FQL 28
FO17, FBO16 T8
Base
Types
Lumens
1 Lamp 2 Lamps
750
-575
750
450
725
300
525
600
700
475
575
350
425
650
-575
750
475
550
300
400
525
650
525
700
600
700
425
500
Input
Wattage
3.5
Application
LAMPAK Series UFO-12W emergency power pack does
not affect normal fixture operation and may be used
with either a switched or unswitched fixture. The UFO12W may be installed on top of, or remote from the
fixture. The emergency ballast may be remotely installed
up to half the distance from the lamp the AC ballast
manufacturer recommends, or up to 50 feet, whichever
is less. UFO-12W emergency power packs are not suitable for installation in heated air outlet fixtures and wet
or hazardous location fixtures. Installation is not recommended with fixtures where the ambient temperature
may fall below 0°C (32°F ).
Dimensions
* Partial listing of lamps operated
Initial lumen output measured at 25°C ambient temperature.
1.5”
3.8cm
9.4”
23.8cm
2.4”
6.0cm
36
Lampak
Low-Profile Fluorescent Power Packs
Features
• Low profile design
• Compatible with electronic
(including those containing
end-of-life shutdown circuits),
standard magnetic, energy saving,
and dimming AC ballasts
• Compatible with most standard
and HO T5 miniature bipin, T8
bipin and rapid-start (4-pin)
long compact lamps
• Easy ballast channel installation
• Operates one lamp
• Can be used with switched or
unswitched lighting fixtures
UFO-LP
• Compact battery case
• Reliable, high-frequency inverter
• Premium sealed nickel-cadmium
battery
• Universal 120/277VAC operation
• Test switch and LED charge indicator
light supplied standard
• Provides 90 minutes of emergency
lighting
• Low power consumption
• Temperature range: 0°C to 50°C
(32°F to 122°F)
• UL 924 Listed (Emergency Lighting)
W
NE
Ordering Information
UFO-LP1 (Standard Output Model)
UFO-LP2 (High Output Model)
Options
(Add
Accessories
(Order Separately)
SPRTS Remote test switch/charge indicator
module (1)
(1) Fits
single-gang box.
ccessories
(Order Separately)
A
suffix to model)
Product Selector Guide
Electrical
Base
Catalog
Number
Lumen
Output
Number
of Lamps
Operated
UFO-LP1
UFO-LP2
See Table 1
See table 2
1
1
Lamp Type
Lumens
700
FP54, F54 T5/HO
FP39, F39 T5/HO
620
FP24, F24 T5/HO
390
FP28, F28 T5
700
FP21, F21 T5
620
FP14, F14 T5
430
F32 T8 (4’)
635
F40 T8 (5’)
570
F48 T8/HO (4’) (44W)
470
PL-L 50W, F50BX/RS, Dulux L 55W 510
PL-L 40W, F40/30BX, Dulux L 55W 625
PL-L 36W, F39/36BX, Dulux L 55W 610
T5 HO, T5, T8 HO, T8, 4-pin Compact
T5 HO, T5, T8 HO, T8, 4-pin Compact
Input
Wattage
3.2
3.0
Table 2 (UFO-LP2)*
Table 1 (UFO-LP1)*
Lamp
Types
* Partial listing of lamps operated.
Initial lumen output measured at 25°C
ambient temperature.
Lamp Type
Lumens
1250
FP54, F54 T5/HO
FP39, F39 T5/HO
1125
FP24, F24 T5/HO
725
FP28, F28 T5
1325
FP21, F21 T5
1025
FP14, F14 T5
750
F17 T8
650
F25 T8
750
F32 T8 (4’)
1100
F40 T8 (5’)
1325
F48 T8/HO (4’) (44W)
1100
F60 T8/HO (5’) (55W)
1275
PL-L 50W, F50BX/RS, FT55DL
1050
PL-L 40W/RS, F40/30BX, FT40DL/RS 925
PL-L 36W, F39/36BX, FT36DL
900
Dimensions
1.18” (3.0cm)
Application
Dual-Lite Lampak UFO-LP Series low-profile fluorescent
emergency ballasts work in conjunction with a low-profile or
standard-size electronic AC ballast containing an end-of-life
shut down circuit to convert new or existing standard or high
output T5 fluorescent fixtures into unobtrusive emergency
lighting. Model UFO-LP1 can be used with one 14 - 28W
standard or 24 - 54W high output T5; one 32W (4’), 40W (5’)
and 44W H0 (4’) T8 fluorescent lamp; or one 36 - 55W (4-pin)
long compact fluorescent lamp (see Table 1). Model UFOLP2 can be used with one 14 - 54W (2’ - 4’) standard or high
output T5, 17 -55W (2’ - 5’) standard or high output T8, 36
- 55W (4-pin) long compact fluorescent lamp (see Table 2).
UFO-LP Series models are also compatible with most 1, 2, 3,
and 4-lamp electronic (including those containing end-of-life
shutdown circuits), standard, energy saving, and dimming AC
ballasts. If used in an emergency-only fixture, no AC ballast is
necessary. UFO-LP Series models are suitable for use in indoordry locations except air handling heated air outlet fixtures,
and wet, damp, or hazardous location fixtures. For information
about specific lamp and ballast compatibility, please contact
the factory.
UFO-LP1 = 18.5” (41.4cm)
UFO-LP2 = 21.5” (54.6cm)
1.18” (3.0cm)
37
Lampak
HID Backup Ballast
Features
UFO-MH
W
NE
An
Severe Conditions Product Line
Damp
• Catches and maintains the arc of
metal halide HID lamps
• Provides two minutes of continuous
arc maintenance
• Maintains lamp at 20-30% normal
operating power
• Multiple catches from one
recharging
• Works with standard constant
wattage autotransformer (CWA)
magnetic ballasts
• Compatible with most standard
150 to 400 watt probe-start metal
halide M57, M58 and M59 HID
lamps
• Easy remote installation
• Battery case made of heavy 22gauge steel
• Reliable, high-frequency inverter
• Premium sealed nickel-cadmium
battery
• Universal 120/277VAC operation
• LED charge indicator light
• Low power consumption
• Temperature range: 0°C to 55°C
(32°F to 131°F)
• UL 924 Listed (Auxiliary Lighting)
• UL Damp Location Listed
Ordering Information
UFO-MH175
UFO-MH250
UFO-MH400
Options (Add suffix to model)
Product Selector Guide
Base
Catalog
Number
Maximum
Distance From
Lamp
Maintenance
Period
UFO-MH175
UFO-MH250
UFO-MH400
30 Feet
50 Feet
80 Feet
2 Minutes
2 Minutes
2 Minutes
Arc
Accessories
(Order Separately)
Electrical
Lamp Types
Operated
175W or 150W energy saving MH (M57)
250W or 225W energy saving MH (M58)
400W or 360W energy saving MH (M59)
Input
Wattage
6W @ 120VAC
6W @ 120VAC
10W @ 277VAC
10W @ 277VAC
Application
The Dual-Lite Lampak UFO-MH Series devices are
battery-operated backup ballasts that catch and
maintain the arc of one metal halide HID lamp
during AC power sags, interruptions or failures.
The UFO-MH Series device works in conjunction
with standard constant wattage autotransformer
(CWA) magnetic ballasts. The UFO-MH device
detects AC power line disturbances and operates
the HID lamp with sufficient power to keep
the lamp arc from extinguishing during power
line disturbances. The lamp arc, in a typical HID
lamp, will extinguish if an AC power failure
persists for more than four milliseconds. The
UFO-MH unit detects AC power line disturbances,
then supplies supplemental power to the lamp
within approximately two milliseconds, thereby
maintaining the lamp arc. The UFO-MH Series is
suitable for damp location use. It is also for use
with listed indoor fixtures EXCEPT air handling
heated air outlets and wet or hazardous location
fixtures. The UFO-MH Series may be used with an
auxiliary generator or inverter power system and
the unit’s two-minute time limit allows more than
ample time for an auxiliary generator to pick up
and support the metal halide lamp for emergency
lighting purposes.
38
Dimensions
12.25”
31.1cm
1.75”
4.4cm
7.25”
18.4cm
Exit Signs
LX Series
DK Series
LT Series
NYXC Series
SMC Series
Sempra Series
Sempra MR
Sempra SC
Sempra SCWL
Sempra SERS
NYDC Series
LN4X Series
Freedom LED
LEDS Series
NYX Series
CMX Series
LE Series
LES Series
NYE Series
NYES Series
DEX Series
Designer LED Exit Signs...................................................................40
AC Incandescent Exit Signs..............................................................41
Designer Tandem Units. .................................................. 42, 43
New York Tandem Units......................................................... 44
Tandem Units with Side Mounted Heads. ................................ 45
Diecast LED Exit Signs.................................................................... 47
Master/Remote Diecast LED Exit Signs.................................... 48, 49
Severe Conditions Diecast LED Exit Signs............................... 50, 51
Wet Location Diecast LED Exit Signs...............................................52
Recessed Diecast LED Exit Signs......................................................53
New York Diecast LED Exit Signs.....................................................54
Wet Location LED Exit Signs.................................................... 55
Aluminum LED Exit Signs.................................................................56
Low-Profile Aluminum LED Exit Signs...................................... 57
New York LED Exit Signs......................................................... 58
Chicago Exit Signs.................................................................. 59
Recessed Mounting Edge-Lit LED Exit Signs........................... 60, 61
Surface Mounting AC Edge-Lit LED Exit Signs....................... 62, 63
New York Recess Mounted Edge-Lit LED Exit Signs.......................64
New York Surface Mounted Edge-Lit LED Exit Signs.....................65
Special Wording Incandescent Exit Signs.................................. 66
39
LX
Designer LED Exit Signs
Features
All Models
• UV-stable thermoplastic housing
• Compact, low-profile design
• Easy to install
• Long-life LED lamps
• Bright, even illumination
• Red and green letters
• Universal single/double face
• White and black models offered
• Push-in wiring connectors
• Universal end/ceiling/wall mount
• Universal snap-in, chevron
arrows
An
Damp
Severe Conditions Product Line
Ordering Information
LX
U R
W
• Damp location listed
• 120/277VAC, 60 Hz operation
Emergency Models
• Solid-state charger with low
voltage disconnect
• Maintenance-free NiCad battery
• 2 hour emergency operation
• Test switch and AC-On light
• Available with Spectron®
self-testing/self-diagnostic
electronics with time-delay relay
(TDR) standard
• Temperature range: 10°C to 40°C
(50°F to 104°F)
• UL 924 Listed
E -FAP
Series
Options
Operation
Faces
Blank - AC Only
E
- Emergency
U - Universal Single/Double Face
Letter Color
Also available in black finish
Housing
Finish
R - Red
G - Green
W - White
B - Black
Options
I
-2C
-FAP
-FM
-AF
-DC
-24K
-SA
(Add
suffix to model)
Spectron self-testing/self-diagnostic electronics
2-circuit operation (2)(6)
Fire alarm panel interface (3)(5)(6)
Flasher module (1)(5)
Audible/Flasher module (1)(5)
Remote DC operation (2)(4)(5)
220-240VAC, 60 Hz. operation
“SALIDA” stencil face
(1)
(2)
(3)
(4)
For specification with emergency models only.
For use with AC models only.
Operates with 24-volt AC or DC fire alarm panels.
For emergency illumination of sign from remote 6-24 VDC
power sources.
(5) -FAP, -FM, -AF or -DC options may not be specified together.
(6) -2C and -FAP options may be specified together.
Power Consumption
40
120VAC
277VAC
Red AC Only Models
2.6 watts
2.6 watts
Green AC Only Models
2.1 watts
2.1 watts
Red Emergency Models
3.8 watts
3.8 watts
Green Emergency Models
Power factor, average: .8 (lagging)
3.5 watts
3.5 watts
Accessories
FX2-E
FX-E
PMLXW
PMLXB
WGLX
WG-MLT
WGLXC
WGLXE
VRS3
(Order Separately)
Emergency operation conversion module (red)
Emergency operation conversion module (green)
121/2” Pendant mounting kit (white)
121/2” Pendant mounting kit (black)
Wire guard (Wall mount)
Wire guard (Wall mount)
Wire guard (Ceiling mount)
Wire guard (End mount)
Vandal resistant shield
Dimensions
DK
Incandescent Exit Sign
Features
• High impact thermoplastic
housing with steel faceplate
• Universal directional chevron
arrow knockouts
• Tamper resistant screws supplied
• AC illumination provided by two
145V, 15T6 incandescent lamps
• May be wall, ceiling or end
mounted
• Universal single/double face
• White finish
• Red letter models
• 120V standard
• Suitable for damp locations
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL 924 Listed
An
Severe Conditions Product Line
Damp
Ordering Information
Model Number
Description
DKURW
DKURWE
120V, AC-Only, single or twin face – universal mount, white finish
120/277V, emergency, single or twin face – universal mount, white finish
Options
(Add
Accessories
suffix to model)
PMEXW
WG-MLT
WGLXC
VRS3
(Order Separately)
12” pendant stem and canopy kit – white
Wire guard (wall mount)
Wire guard (ceiling or end mount)
Vandal resistant shield
Emergency model with power pack
Dimensions
11” (27.9 cm)
5”
(12.7 cm)
CANOPY
1
/2”
(1.3 cm)
Power Pack
4 3/4”
(12.0 cm)
11” (27.9 cm)
21/2”
1
/2”
(1.3 cm)
8”
(6.4 cm)
(20.4 cm)
7 1/2”
(19.1 cm)
31/4”
(8.3 cm)
(DKURWE model)
51/2”
(14.0 cm)
111/4”(28.6 cm) with power pack
3
2 /8”
(6.0 cm)
1
11 /2” (29.2 cm)
41
LT
Designer Tandem Units
Features
• Factory assembled emergency
unit/LED exit sign
• UV-stable thermoplastic housing
• Eyeball style lighting heads
• High-output halogen lamps
• White or black finishes offered
• Remote capacity and damp
location listed models available
• 120/277VAC, 60 Hz operation
• Solid-state charger
• Maintenance-free battery
• Low-voltage disconnect
• Test switch and AC-On light
• Available with Spectron®
self-testing/self-diagnostic
An
Damp
Severe Conditions Product Line
electronics with time-delay relay
(TDR) standard
• Long-life LED lamps
• Bright, even illumination
• Universal single/double face
• Red and green letter models
• Snap-in, chevron arrows
• Ceiling or wall mount models
standard. Optional side mounting
requires accessory kit
• Temperature range: 20°C to 30°C
(68°F to 86°F)
(Damp location models: 10°C to 40°C
(50°F to 104°F)
• UL 924 Listed
Ordering Information
LT
U R
B
D -AF
Series
Options
Application
Faces
Blank - Standard model
- Remote capacity model
3
- Damp location model
D
U - Universal Single/Double Face
Letter Color
Housing
Finish
R - Red
G - Green
Also available in black finish
W - White
B - Black
Options
(Add
suffix to model)
Accessories
(Order Separately)
Power Consumption
120VAC
277VAC
Red Emergency Models
5.0 watts
5.0 watts
Green Emergency Models
5.0 watts
5.0 watts
Dimensions
3 5/8"
(9.2 cm)
Power factor, average: .8 (lagging)
Photometrics
High-Output Halogen Lamp
Horizontal Isofootcandle Distribution
5W MR-16 Lamp
• Standard Lamp for LT unit
• 5W Lamp for LZR Remote Fixtures
10W MR-16 Lamp
• 10W Lamp for
LZR Remote Fixtures
14 1/4"
(36.2 cm)
17/8" (4.7
5 cm)
13"
(33 cm)
42
LT
Product Selector Guide
Remote Damp
Colors
Standard
Capacity Location Exit Stencil
Models Models(1) Models Letters Housing Face(s) Description
LTURW
LTURW3
LTURWD
Red
White
White
Single/double face tandem unit
LTURB
LTURB3
LTURBD
Red
Black
Black
Single/double face tandem unit
LTUGW
LTUGW3
LTUGWD
Green
White
White
Single/double face tandem unit
LTUGB
LTUGB3
LTUGBD
Green
Black
Black
Single/double face tandem unit
(1) Operates the integral unit heads plus one additional 5 watt lighting fixture or exit sign.
Options
(Add
Accessories
suffix to model)
I
-0
-FAP
Spectron self-testing/self-diagnostic electronics (4)
Unit supplied without lighting heads (3)
Fire alarm panel interface (1)(2)
-FM
-AF
-24K
-SA
Flasher module (2)
Audible/Flasher module (2)
220-240VAC, 60 Hz operation
“SALIDA” stencil face
(1) Operates with 24-volt AC or DC fire alarm panels.
(2) -FAP, -FM, or -AF options may not be specified together.
(3) Available with remote capacity (LTXXX3) models only.
(4) Only available on remote capacity and damp location models.
FTSMKW
FTSMKB
PMLZTW
PMLZTB
(Order Separately)
Side mount field kit (white) (a)
Side mount field kit (black) (a)
121/2” Pendant mounting kit (white)
121/2” Pendant mounting kit (black)
WGTW
WGTCE
VRS2
OMSSW0605
Wire guard (Wall mount)
Wire guard (Ceiling or end mount)
Vandal resistant shield (b)
Outdoor remote lighting head -
6 Volt, 5 Watt sealed-beam type lamp White finish
OMSSB0605
Outdoor remote lighting head -
6 Volt, 5 Watt sealed-beam type lamp Black Finish
(a) FTSMKW and FTSMKB field kits are required for side mounting on all
models. Accommodates left side mounting only.
(b) For use with wall mounted units only.
OMS Series outdoor lighting
heads
Matching Remote Fixtures
A complete line of 6- and 12-volt matching remote fixtures
in single and tandem lamp configurations is available for
use with LZ Series high-capacity units or any other 6- or 12volt DC emergency lighting remote power sources.
All remote fixtures are offered in black and white textured
finishes with a choice of 5- or 10-watt halogen lamps.
White Black
Single Single
Volts Watts
LZRSW0605
LZRSB0605
6
5
LZRSW0610
LZRSB0610
6
10
LZRSW1205
LZRSB1205
12
5
LZRSW1210
LZRSB1210
12
10
43
NYXC
New York City Tandem Unit
Features
• Designed to meet New York City
specifications
• Heavy 20 gauge metal enclosure
with white or black finish
• Exit plaques secured by channels
• Single face eight inch high letters
• Knockout directional chevron
arrows
• Available with two or three fully
adjustable and lockable 7.2 watt
thermoplastic lighting heads
• High output LED lamps
• Universal 120/277VAC operation
W
NE
•
•
•
•
Wall mounting
Completely self-contained
90-Minute emergency operation
Environmentally coated, fully
automatic solid state charger
• Automatic low voltage battery
disconnect
• Charge rate indicator and test
switch
• Maintenance free battery
• Temperature range: 0°C to 40°C
(32°F to 104°F)
• Listed to UL 924
Ordering Information
NYXC S R
B
E
2
Options
Series
Operation
Faces
E - Emergency
S - Single
D - Double
W - White
B - Black
R - Red
Options
Number of
Lighting
Heads
Housing
Finish
Letter Color
-0612
-TR
(Add
12 watt lamps
2 - Two
3 - Three
suffix to model)
(1)
Tamper resistant
Options
(Addoption
suffix to model)
(2)
-TR
Accessories
(Order Separately)
(1) 12 watt high-output lamps available on two-headed models only.
(2) Provides two stainless steel tamper resistant locking screws.
Accessories
40G
(Order Separately)
Wire guard (wall mount)
Dimensions
Power Consumption
All Models
120VAC
7.0W
277VAC
7.2W
* Wattage figures include LED lamps, transformers and electronics
power requirements.
Photometrics
Horizontal Isofootcandle Distribution
Standard 6V, 7.2W SBT Lamp
B
A
C
A
B
C
D
15 1/2”
15”
4 1/4”
9 5/8”
24.4 cm 39.4 cm 38.1 cm 10.8 cm
44
D
SMC
Combination LED Exit/Emergency Light
Features
• Combines emergency light with
energy saving LED exit
• Adjustable 5.4 watt incandescent
lampheads
• Maintenance-free battery
• Dual voltage – 120V/277VAC
• Fast, easy installation
• Snap together, modular
construction
• All components are integral
to the exit housing, including
battery
• Accessible compartments add to
ease of maintenance
• Consumes as little as 4 watts for
either a single or twin face sign
• Uniform illumination of
exit legend
• Snap-out directional chevrons
• Temperature range:
20°C to 30°C
(68°F to 86°F)
• UL 924 Listed
W
NE
Ordering Information
SMC 3 R
Series
E
CB W
Housing
Finish
Operation
E - Emergency
W - White
B - Black
Faces
3 - Universal Single or Double
Mounting
CB - Ceiling/Back
E - End
Letter Color
R - Red
G - Green
Available March 1, 2006
Options
(Add
Accessories
41G
suffix to model)
Accessories
(Order Separately)
(Order Separately)
Wire guard (wall or ceiling mount)
Dimensions
End Mount
13 3/8”
(34 cm)
12 1/2”
Ceiling or Back Mount
21 1/2” max.
1
4 /2”
(54.6 cm)
(11.4 cm)
max.
12 1/2”
(31.8 m)
(31.8 cm)
10 1/8”
(13.3 cm)
45
Sempra
Diecast LED Exit Sign
Features
All Models
• High-strength cast aluminum
• Low-profile architectural styling
• 5-minute installation
• Long-life LED lamps
• Bright, even illumination
• Red and green letters
• Single and double face models
• White, black and black or white
with brushed face finishes
• Push-in wiring connectors
• Universal end/ceiling/wall mount
• Break-out, chevron arrows and
TY ON
mounting KOs
N
A
R
AR
S
L
W
E
E
• 120/277VAC, 60 Hz operation
rdering
nformation
OD
TIM
OLIFE
IM
N
CTRO
LL SPE
Emergency Models
• Solid-state charger with low voltage
disconnect
• Maintenance-free NiCad battery
• 2-hour emergency operation
• Test switch and AC-On indicator
• Available with Spectron® selftesting/self-diagnostic electronics
with time-delay relay
(TDR) standard
• Lifetime warranty on LED strip,
electronics and battery with
Spectron® self-testing/selfdiagnostic models
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL 924 Listed
A
Ordering Information
See Product Selector Guide for available models
Special Wording Diffus-
Options
(Add
suffix to model)
Lifetime Warranty
Sempra cast-aluminum emergency exit signs with the
Spectron self-testing/self-diagnostic electronics system
are guaranteed by Dual-Lite under normal and proper
use, against defects in material and workmanship
for the life of the product. The warranty covers all
electronics,
LED light strip and
battery.
ccessories
(Ounit
rder
Separately)
A
Special Wording Open Face Diffuser Table*
Option No.
-SW1
-SW2
-SW3
-SW4
-SW5
-SW6
-SW7
-SW8
-SW9
-SW10
-SW11
Description
TO EXIT
NOT AN EXIT
IN USE
XRAY IN USE
DARKROOM IN USE
CAUTION
DO NOT ENTER
TEST IN PROGRESS
ON AIR
AREA OF REFUGE
AREA OF REFUGE
(w/wheelchair symbol)
Option No.
-SW12
-SW13
-SW14
-SW15
-SW16
-SW17
-SW18
-SW19
Description
AREA OF RESCUE ASSISTANCE
AREA OF RESCUE ASSISTANCE
(w/wheelchair symbol)
ELEVATOR
RESTROOMS
MEN
MEN (w/symbol)
WOMEN
WOMEN (w/symbol)
Other special wording diffusers
available, consult factory.
* To order special wording diffusers, add Option Number suffix to model number.
Ex: SEDRWE-SW(10)
Power Consumption
Red AC Only Models:
Green AC Only Models:
Red Emergency Models:
Green Emergency Models:
120VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts
277VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts
*Wattage figures include LED lamps, transformer and electronics power
requirements. LED lamp assemblies (red or green) consume less than 1 watt.
Power factor, average: .8 (lagging)
46
Push-in quick-connect
AC terminals
Universal
wall mounting
KO pattern
Wiring
channel
LED
illumination
strip
Isolated,
grounded
120/277VAC
transformer
Break-out
chevron-style
directional indicators
Charger/transfer
module
Sealed
nickel-cadmium
battery
Sempra
Product Selector Guide
AC Emergency Number
Colors
Model Model
of Exit Stencil
Numbers Numbers Faces Letters
Housing Face(s)
SESRW
SESRWE
Single
Red
White
White
SESGW
SESGWE
Single
Green
White
White
SESRWN
SESRWNE
Single
Red
White
Brushed
SESGWN
SESGWNE
Single
Green
White
Brushed
SESRB
SESRBE
Single
Red
Black
Black
SESGB
SESGBE
Single
Green
Black
Black
SESRBN
SESRBNE
Single
Red
Black
Brushed
SESGBN
SESGBNE
Single
Green
Black
Brushed
SEDRW
SEDRWE
Double
Red
White
White
SEDGW
SEDGWE
Double
Green
White
White
SEDRWN
SEDRWNE
Double
Red
White
Brushed
SEDGWN
SEDGWNE
Double
Green
White
Brushed
SEDRB
SEDRBE
Double
Red
Black
Black
SEDGB
SEDGBE
Double
Green
Black
Black
SEDRBN
SEDRBNE
Double
Red
Black
Brushed
SEDGBN
SEDGBNE
Double
Green
Black
Brushed
Options
I
-DC
-2C
-FAP
-FM
-AF
-24K
(Add
suffix to model)
Spectron self-testing/self-diagnostic electronics
Remote DC operation (1)(4)(5)
2-circuit operation (1)(5)
Fire alarm panel interface (3)(5)
Flasher module (2)(5)
Audible/Flasher module (2)(5)
220/240VAC, 60 Hz. operation
(1) For use with AC models only.
(2) For use with emergency models only.
(3) Operates with 24-volt AC or DC fire alarm panels.
(4) For emergency illumination of sign from remote 6-24 VDC power sources.
(5) -DC, -2C, -FAP, -FM, -AF options may not be specified together.
Accessories
SER-E
SEG-E
PMCW
PMCB
WGLX
WG-MLT
WGLXC
WGLXE
(Order Separately)
Emergency operation module (red models) *
Emergency operation module (green models) *
121/2” Pendant mounting kit (white)
121/2” Pendant mounting kit (black)
Wire guard (Wall mount)
Wire guard (Wall mount)
Wire guard (Ceiling mount)
Wire guard (End mount)
* For factory-equipped emergency models, see Product Selector Guide above.
Dimensions
9 1/8”
(23 cm)
10”
(25.5 cm)
11 3/4” (30 cm)
12 5/8” (32 cm)
1 5/8” (4.14 cm)
47
Sempra MR
Master/Remote Diecast LED Exit Signs
Features
All Models
• High-strength, low-profile cast
aluminum housing
• Supplied as 2-sign,
Master/Remote sets
• 5-minute installation
• Long-life LED lamps
• Bright, even illumination
• Red or green letters
• Single and double face models
N
NTY O
A
• White, black and black or white
R
R
E WA MODELS
M
with brushed face finishes
I
T
E
N
LIF
RIOnformation
Ordering
T
C
E
P
• Push-in wiring connectors
ALL S
• Universal end/ceiling/wall mount
• Break-out, chevron arrows
• 120/277VAC, 60 Hz operation
Master Signs
• Solid-state charger with low
voltage disconnect
• Maintenance-free NiCad battery
• 90 minute emergency operation
• Test switch and AC-On indicator
• Available with Spectron® selftesting/self-diagnostic electronics
with time-delay relay
(TDR) standard
• Lifetime warranty on LED strip,
electronics and battery with
Spectron® self-testing/self-
diagnostic models
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL 924 Listed
Remote Signs
• Surface mounts to standard
electrical boxes
• Connects to Master sign using
conventional wiring methods
Ordering Information
SEMR S R
W
E -FAP
Series
Options
Operation
Faces
Blank - AC Only
E
- Emergency
S - Single
D - Double
OLetter
ptions
Color
R - Red
G - Green
(Add
suffix to model)
Housing
Finish
W - White
B - Black
WN - White with brushed face
BN - Black with brushed face
Lifetime Warranty
Sempra cast-aluminum emergency exit signs with the
Spectron self-testing/self-diagnostic electronics system
are guaranteed by Dual-Lite under normal and proper
use, against defects in material and workmanship
for the
life of the product. The
covers all
ccessories
(Owarranty
rder Separately
)
electronics, LED light strip and unit battery.
A
Dimensions
Master
Signs
9 1/8”
(23 cm)
10”
(25.5 cm)
11 3/4” (30 cm)
12 5/8” (32 cm)
1 5/8”
(4.14 cm)
12 3/8” (31.4 cm)
Remote Signs
5
/8”
(1.6 cm)
9 5/8”
(24.4 cm)
48
Sempra MR
Product Selector Guide
AC Emergency Number
Colors
Model Model
of Exit Stencil
Numbers Numbers Faces Letters
Housing Face(s)
SEMRSRW
SEMRSGW
SEMRSRWN
SEMRSGWN
SEMRSRB
SEMRSGB
SEMRSRBN
SEMRSGBN
SEMRDRW
SEMRDGW
SEMRDRWN
SEMRDGWN
SEMRDRB
SEMRDGB
SEMRDRBN
SEMRSRWE
SEMRSGWE
SEMRSRWNE
SEMRSGWNE
SEMRSRBE
SEMRSGBE
SEMRSRBNE
SEMRSGBNE
SEMRDRWE
SEMRDGWE
SEMRDRWNE
SEMRDGWNE
SEMRDRBE
SEMRDGBE
SEMRDRBNE
Single
Single
Single
Single
Single
Single
Single
Single
Double
Double
Double
Double
Double
Double
Double
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
White
White
White
White
Black
Black
Black
Black
White
White
White
White
Black
Black
Black
White
White
Brushed
Brushed
Black
Black
Brushed
Brushed
White
White
Brushed
Brushed
Black
Black
Brushed
SEMRDGBN
SEMRDGBNE
Double
Green
Black
Brushed
Options
I
-DC
-2C
-FAP
-FM
-AF
-24K
-VTR
(Add
suffix to model)
Spectron self-testing/self-diagnostic electronics
Remote DC operation (1)(4)(5)
2-circuit operation (1)(5)
Fire alarm panel interface (3)(5)
Flasher module (2)(5)
Audible/Flasher module (2)(5)
220/240VAC, 60 Hz. operation
Vandal/tamper resistant option (6)
Accessories
PMCW
PMCB
WGLX
WG-MLT
WGLXC
WGLXE
(Order Separately)
Pendant mounting kit (white) (a)
Pendant mounting kit (black) (a)
Wire guard (Wall mount) (a)
Wire guard (Wall mount) (a)
Wire guard (Ceiling mount) (a)
Wire guard (End mount) (a)
(a) For use with Master exit signs only.
(1) For use with AC models only.
(2) For use with emergency models only.
(3) Operates with 24-volt AC or DC fire alarm panels.
(4) For emergency illumination of sign from remote 6-24 VDC power sources.
(5) -DC, -2C, -FAP, -FM, -AF options may not be specified together.
(6) Provides polycarbonate face shield and tamper-proof screws. Meets UL listing
requirements for floor proximity use.
Beveled, low-profile design
on Remote signs meet ADA
requirements and UL Listing
requirements for floor
proximity use with -VTR option
Power Consumption
Sempra MR signs equipped with -VTR
vandal/tamper resistant option shield
and hardware.
Red AC Only Models:
Green AC Only Models:
Red Emergency Models:
Green Emergency Models:
120VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts
277VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts
*Wattage figures include LED lamps, transformer and electronics power
requirements. LED lamp assemblies (red or green) consume less than 1 watt.
Power factor, average: .8 (lagging)
49
Sempra SC
An
Severe Conditions Diecast LED Exit Signs
Features
All Models
• High-strength cast aluminum
• Low-profile architectural styling
• 5-minute installation
• Polycarbonate face shield
provides additional protection
against vandalism
• Tamper-resistent screws prevent
entry by unauthorized personnel
• Long-life LED lamps
• Bright, even illumination
• Red and green letters
• Single and double face models
• White, black and black or white
Severe Conditions Product Line
with brushed face finishes
rdering nformation
•
Push-in wiring connectors
VandalTampering
Damp
Hot
Cold
• Universal end/ceiling/wall mount
• Break-out, chevron arrows and
TY ON
mounting KOs
N
A
R
LS
WAR
E
E
•
UL Damp Location listed
D
M
O
I
LIFET
ON M
R
•
120/277VAC, 60 Hz operation
T
C
E
P
O
I
ALL S
Emergency Models
• Solid-state charger with low
voltage disconnect
• Maintenance-free NiCad battery
• 90 minute emergency operation
• Test switch and AC-On indicator
• Available with Spectron® selftesting/self-diagnostic electronics
with time-delay relay
(TDR) standard
• Lifetime warranty on LED strip,
electronics and battery with
Spectron® self-testing/self-
diagnostic models
• Temperature ranges:
AC models:
-20°C to 50°C
(-4°F to 122°F)
Emergency models: 0°C to 40°C
(32°F to 104°F)
Emergency models
with -XTR option: -20°C to 50°C
(-4°F to 122°F)
• UL 924 Listed
Ordering Information
See Product Selector Guide for available models
Lifetime Warranty
Options
(Add
suffix to model)
Sempra SC cast-aluminum emergency exit signs with the
Spectron self-testing/self-diagnostic electronics system are
guaranteed by Dual-Lite under normal and proper use,
ccessories
(Order Separately
against defects
in material and workmanship
for the life of )
the product. The warranty covers all electronics, LED light
strip and unit battery.
A
Push-in quick-connect
AC terminals
Universal wall mounting
KO pattern
Wiring
channel
LED
illumination
strip
Polycarbonate face shield provided
standard on all Sempra SC models
Isolated,
grounded
120/277VAC
transformer
Power Consumption
Red AC Only Models:
Green AC Only Models:
Red Emergency Models:
Green Emergency Models:
120VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts
277VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts
*Wattage figures include LED lamps, transformer and electronics power
requirements. LED lamp assemblies (red or green) consume less than 1 watt.
Power factor, average: .8 (lagging)
50
Break-out
chevron-style
directional
indicators
Charger/transfer module
Sealed
nickel-cadmium
battery
Sempra SC
Product Selector Guide
AC Emergency Number
Colors
Model Model
of Exit Stencil
Numbers Numbers Faces Letters
Housing Face(s)
SCSRW
SCSRWE
Single
Red
White
White
SCSGW
SCSGWE
Single
Green
White
White
SCSRWN
SCSRWNE
Single
Red
White
Brushed
SCSGWN
SCSGWNE
Single
Green
White
Brushed
SCSRB
SCSRBE
Single
Red
Black
Black
SCSGB
SCSGBE
Single
Green
Black
Black
SCSRBN
SCSRBNE
Single
Red
Black
Brushed
SCSGBN
SCSGBNE
Single
Green
Black
Brushed
SCDRW
SCDRWE
Double
Red
White
White
SCDGW
SCDGWE
Double
Green
White
White
SCDRWN
SCDRWNE
Double
Red
White
Brushed
SCDGWN
SCDGWNE
Double
Green
White
Brushed
SCDRB
SCDRBE
Double
Red
Black
Black
SCDGB
SCDGBE
Double
Green
Black
Black
SCDRBN
SCDRBNE
Double
Red
Black
Brushed
SCDGBN
SCDGBNE
Double
Green
Black
Brushed
Options
I
-DC
-2C
-FAP
-FM
-AF
-24K
-XTR
(Add
suffix to model)
Spectron self-testing/self-diagnostic electronics
Remote DC operation (1)(4)(5)
2-circuit operation (1)(5)
Fire alarm panel interface (3)(5)
Flasher module (2)(5)
Audible/Flasher module (2)(5)
220/240VAC, 60 Hz. operation
Extreme temperature operation (2)(6)
Accessories
PMCW
PMCB
WGLX
WG-MLT
WGLXC
WGLXE
(Order Separately)
121/2” Pendant mounting kit (white)
121/2” Pendant mounting kit (black)
Wire guard (Wall mount)
Wire guard (Wall mount)
Wire guard (Ceiling mount)
Wire guard (End mount)
(1) For use with AC models only.
(2) For use with emergency models only.
(3) Operates with 24-volt AC or DC fire alarm panels.
(4) For emergency illumination of sign from remote 6-24 VDC power sources.
(5) -DC, -2C, -FAP, -FM, -AF options may not be specified together.
(6) For use with Sempra SC emergency models only (Spectron models excluded).
Dimensions
9 1/8”
(23 cm)
10”
(25.5 cm)
11 3/4” (30 cm)
12 5/8” (32 cm)
1 5/8” (4.14 cm)
51
Sempra SC
Wet Location Environmental LED Exit Sign
Features
Wet Location
W
NE
All Models
• Designed for wet location and
high abuse applications
• Full neoprene gasket
• Durable cast aluminum housing in
black finish
• Polycarbonate face shields secured
with stainless hardware
• Universal ceiling, end or wall
surface mounting
• 120/277VAC operation standard
• Bright, even illumination
An
• Red and green letter models
• Snap-out chevron arrows
Severe Conditions Product Line
• High output, long-life LED lamps
rdering nformation
• Temperature range: 0°C to 45°C
(32°F to 114°F)
Damp
Corrosive
Wet
Cold*
O
I
*With Heater
Option
Emergency Models
• Completely self-contained
• Fully automatic, environmentally
coated charger
• Maintenance-free NiCad battery
• Low voltage disconnect
• Test switch and AC-On indicator
• 90 minute operation
• Optional 120 minute operation
• Temperature range: 0°C to 45°C
(32°F to 114°F)
• Temperature range with heater
-40°C to 45°C
option:
(-40°F to 114°F)
• Vandal-resistant housing with
tamper-resistant screws
• Listed to UL 924
Availability To Be Announced
Ordering Information
SCWL S
Series
R
B
E
Operation
Faces
Options
Blank - AC Only
E - Emergency
S - Single
D - Double
Letter Color
R - Red
G - Green
Options
U -AA
(Add
Mounting
Exit Housing
Color
U - Universal
A
(OrdertoSeparately
Occessories
ptions (Add suffix
model) )
- Black
suffix Bto
model)
W - White
-AA
-FM
-AR120
-HTR1
-HTR2
Dimensions
(1) -AA, -FM, -HTR1, and -HTR2 options may not be specified together.
(2) For use with emergency models only.
A
B
C
C
D
E
4”
10” 6.2”
9”
9”
14”
10.2 cm 25.4 cm 15.8 cm 22.9 cm 35.6 cm
Accessories
PMSWL
E
52
B
(Order Separately)
12” Pendant mounting kit
C
D
A
Audible alarm (1)(2)
Flasher module (1)(2)
120 minute emergency operation (2)
Internal heater - 120VAC (1)(2)
Internal heater - 277VAC (1)(2)
Sempra SERS
Recessed Cast Aluminum LED Exit Sign
Features
All Models
• High-strength cast aluminum
• Compact, low-profile style
• Fast, easy installation
• Long-life LED lamps
• Bright, even illumination
• Red and green letters
• Rigid, high impact acrylic letter
panel
• White, black and black or white
with brushed face finishes
• Plug-together wiring connectors
• Break-out, chevron arrows and
mounting KOs
• 120/277VAC, 60 Hz operation
Emergency Models
• Solid-state charger with low
voltage disconnect
• Maintenance-free NiCad battery
• 2-hour emergency operation
• Test switch and AC-On indicator
• Available with Spectron® selftesting/self-diagnostic electronics
with time-delay relay
(TDR) standard
• Lifetime warranty on LED strip,
electronics and battery with
Spectron® self-testing/selfdiagnostic models
• Temperature range: 20°C to 30°C
(68°F to 86°F)
nformation
• UL 924 Listed
Ordering I
N
NTY O
A
R
R
A
DELS
ME W
LIFETI CTRON MO
E
ALL SP
Ordering Information
SERS R WN
E -AF
Series
Options
Letter Color
Lifetime Warranty
Operation
R - Red
G - Green
Blank - AC Only
E
- Emergency
Sempra cast-aluminum emergency exit signs with the
Spectron self-testing/self-diagnostic electronics system
are guaranteed by Dual-Lite under normal and proper
use, against defects in material and workmanship
for the life of the product. The warranty covers all
electronics, LED light strip and unit battery.
Housing Finish
W - White
B - Black
WN - White with brushed face
BN - Black with brushed face
Options
I
-DC
-2C
-FAP
-FM
-AF
-VTR
-LRBB
(Add
suffix to model)
Spectron self-testing/self-diagnostic electronics
Remote DC operation (1)(4)(5)
2-circuit operation (1)(5)
Fire alarm panel interface (3)(5)
Flasher module (2)(5)
Audible/Flasher module (2)(5)
Vandal/tamper resistant option (6)
Sign assembly less rough-in back box (7)
(1) For use with AC models only.
(2) For use with emergency models only.
(3) Operates with 24-volt AC or DC fire alarm panels.
(4) For emergency illumination of sign from remote 6-24 VDC power sources.
(5) -DC, -2C, -FAP, -FM, -AF options may not be specified together.
(6) Provides polycarbonate face shield and tamper-resistant screws. Meets UL
listing requirements for floor proximity use.
(7) Allows ordering of rough-in back box separately for installation prior to sign
shipment. Add “-LRBB” suffix to exit model number if RBB accessory kit is to
be ordered separately.
Accessories
(Order Separately)
RBB
Rough-in back box kit
WGLX Wire guard (Wall mount)
WG-MLT Wire guard (Wall mount)
Dimensions
Rough-In
Back Box
Power Consumption
Red AC Only Models:
Green AC Only Models:
Red Emergency Models:
Green Emergency Models:
120VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts
277VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts
9 5/8”
(24.4 cm)
*Wattage figures include LED lamps, transformer and electronics power
requirements. LED lamp assemblies (red or green) consume less than 1 watt.
Power factor, average: .8 (lagging)
53
NYDC
New York City Cast Aluminum LED Exit
Features
AC Models
• Designed to meet New York City
specifications
• All diecast aluminum construction
• White, black and black with
brushed face finishes
• Break-out directional chevrons
• Single and double face models
with eight inch letters
• Wall/ceiling/end mounting
• Dual voltage – 120/277VAC
• Bright and even illumination
• Long-life LED lamps
W
NE
Emergency Models
• Long life NiCad battery
• 90 minute emergency operation
• Test switch and AC-On indicator
• Environmentally coated, fully
automatic charger
• Temperature range: 0°C to 45°C
(32°F to 113°F)
• Listed to UL 924
Ordering Information
NYDC S R
B
A -FM
Options
Series
Operation
Faces
A - AC Only
E - Emergency
S - Single
D - Double
Housing
Finish
Letter Color
W - White
B
- Black
BN - Black with brushed face
R - Red
Options (Add suffix to model)
O
(Add suffix to model)
-FM ptions
Flasher module
(1)(2)
-AA
Audible alarm module
Available in white, black and
black with brushed face finishes
Accessories
(Order Separately)
(1)(2)
(1) For use with emergency models only.
(2) -FM and -AA options may not be specified together.
Accessories
PMNYW
PMNYB
WGTW
WGTCE
(Order Separately)
Dimensions
Pendant mounting kit (white)
Pendant mounting kit (black)
Wire guard (Wall mount)
Wire guard (Ceiling mount)
B*
A*
C
Power Consumption
* Add 1“ (2.5 cm) for mounting
canopy on ceiling or end mounted models
120VAC
277VAC
AC Only Models
2.4W
2.4W
Emergency Models
3.4W
3.5W
* Wattage figures include LED lamps, transformers and electronics
power requirements.
54
A
B
C
2 5/8”
11”
161/4”
27.9 cm 41.3 cm 6.7 cm
LN4X
Wet Location LED Exit Signs
Features
AC Models
• UL type 4X enclosure for
indoor/outdoor use
• Easily installed to wall surfaces
• Suitable for use in damp, wet,
hose-down and corrosive locations
• Polycarbonate housing
• 120/277VAC operation standard
• Bright, even illumination
• Red and green letter models
• Snap-in chevron arrows
• Long-life LED lamps
• Temperature range: 0°C to 40°C
(32°F to 104°F)
Emergency Models
• Suitable for use in damp, wet and
corrosive locations
• Completely self-contained
• Fully automatic, solid-state charger
• Maintenance-free NiCad battery
• Low voltage disconnect
• Test switch and AC-On light
• Available with Spectron® selftesting/self-diagnostic electronics
with time-delay relay
(TDR) standard
• 120 minute operation
• Temperature range: 10°C to 40°C
(50°F to 104°F)
nformation
• UL 924 Listed
An
Severe Conditions Product Line
Ordering I
Damp
Wet
Vandal &
Tampering
Cold
Corrosive
Ordering Information
LN4X R W
Series
E -FAP
Operation
Blank - AC Only
E
- Emergency
Letter Color
R - Red
G - Green
Exit Face
Color
Options
W - White
Accessories
suffix to model)
(Order Separately)
(1)(2)
120VAC
277VAC
Red AC Only Models
2.6 watts
2.6 watts
Green AC Only Models
2.1 watts
2.1 watts
Red Emergency Models
3.8 watts
3.8 watts
Green Emergency Models
3.5 watts
3.0 watts
Power factor, average: .8 (lagging)
Dimensions
➤
(1) Add “I” Spectron self-testing/self-diagnostic option suffix immediately after base
model number. Example: LN4XRWEI
(2) For specification with emergency models only.
(3) For use with AC models only.
(4) Operates with 24-volt AC or DC fire alarm panels.
(5) For emergency illumination of sign from remote 6-24 VDC power sources.
(6) -FAP, -XTRFAP, -FM or -DC options may not be specified together.
(7) -2C and -XTRFAP or -FAP options may be specified together.
(8) Not for use with self-testing Spectron models.
(9) Provides an operating temperature range of -20°C to 50°C (-4°F to 122°F)
Power Consumption
11 3/4”
(29.8 cm)
➤
15 3/4”
➤
Spectron self-testing/self-diagnostic electronics
Extreme temperature operation (2)(8)(9)
2-circuit operation (3)(7)
Fire alarm panel interface (4)(6)(7)
Extreme temperature operation fire alarm
panel interface (2)(4)(6)(7)(8)(9)
Flasher module (2)(6)
Remote DC operation (3)(5)(6)
Tamper-proof cover screws (includes tool)
➤
I
-XTR
-2C
-FAP
-XTRFAP
-FM
-DC
-TR
(Add
(40 cm)
5
16 /8”
(42.2 cm)
➤
➤
➤
Options
5 1/4” ➤
(13.3 cm)
55
Freedom LED
Aluminum LED Exit Signs
Features
Emergency Models
• Solid-state charger with low
voltage disconnect
• 6-volt, maintenance-free battery
• User-selectable constant on or
flashing emergency illumination
• Up to 12 hour operation
• Test switch, AC-On and charge
indicator lights
• Temperature range: 10°C to 40°C
(50°F to 104°F)
• Damp location listed
• UL 924 Listed
All Models
• Vinyl-clad aluminum housing
• Polycarbonate face shield
standard
• Easy to install
• Long-life LED lamps
• Red and green letters
• Single and double face models
• Six decorator finishes offered
• End, ceiling or wall mount
• Snap-out, chevron arrows
• Damp location listed
• 120/277VAC, 60 Hz operation
An
Damp
Severe Conditions Product Line
Ordering Information
LED
2 EM
Series
R WW -TR
R - Red
G - Green
Available Colors
WW - White
WA - White with Brushed Aluminum Face
BB - Black
BA - Black with Brushed Aluminum Face
TT - Brass
ZZ - Antique Brass
Operation
AC - AC Only
EM - Emergency
Options
Single Double
Face Face
12 Hours 8 Hours
6 Hours 4 Hours
Housing
Finish
1 - Single Face
2 - Double Face
-TR
-2C
-FAP
-BPR
Flashing Mode
Constant On Mode
Options
Letter Color
Faces
-DC
Discharge Times
(Add
Antique Brass
Black
Black/Brushed Face
Brass
White
White/Brushed Face
Accessories
suffix to model)
Remote DC operation(2)(3)(5)
Tamper resistent screws
2-circuit operation(2)(3)(6)
Fire alarm panel interface (flasher)(4)(5)(6)
Beeper module(1)(6)
(Order Separately)
VRS3 Vandal resistant shield
WGTCE Wire guard (Ceiling/End mount)
WGTW Wire guard (Wall mount)
(1) For specification with emergency models only.
(2) For use with AC models only.
(3) For emergency illumination of sign from remote 12 through 48 VDC
power sources.
(4) Operates with 24-volt AC or DC fire alarm panels.
(5) -FAP, and -DC options may not be specified together.
(6) -2C, -BPR and -FAP options may be specified together.
Dimensions
Power Consumption
56
Single Face Models
120VAC
277VAC
Double Face Models
Red AC Only Models
4.47 watts 4.47 watts 6.80 watts 6.80 watts
120VAC
277VAC
Green AC Only Models
4.68 watts 4.64 watts 6.70 watts 6.70 watts
Red Emergency Models
4.99 watts 4.99 watts 7.27 watts 7.22 watts
A
B
C
Green Emergency Models 4.96 watts 4.93 watts 7.65 watts 7.67 watts
7 1/2”
8.0”
31/8”
Power factor, average: .8 (lagging)
19 cm 20 cm 7.9 cm 30.8 cm 32.1 cm 1.3 cm 15.2 cm 10.8 cm
D
E
121/8” 12 5/8”
F
G
H
1/ 2”
6.0”
41/4”
LEDS
Low-Profile Aluminum LED Exit Signs
Features
Emergency Models
• Solid-state charger with low
voltage disconnect
• Maintenance-free Ni-Cad battery
• 90-minute emergency operation
• Test switch and AC-On indicator
light
• Temperature range: 10°C to 40°C
(50°F to 104°F)
• Damp location listed
• UL 924 Listed
All Models
• Vinyl-clad aluminum housing
• Compact, low-profile style
• Easy to install
• Long-life LED lamps
• Red and green letters
• Single, double and universal
single/double face models
• Six decorator finishes offered
• End, ceiling or wall mount
• Snap-out, chevron arrows
• Damp location listed
• 120/277VAC, 60 Hz operation
An
Damp
Severe Conditions Product Line
Ordering Information
LEDS U AC
Series
R
Options
Letter Color
R - Red
G - Green
Faces
WW - White
WA - White with Brushed Aluminum Face
BB - Black
BA - Black with Brushed Aluminum Face
TT - Brass
ZZ - Antique Brass
Operation
AC - AC Only
EM - Emergency
Options
(Add
Antique Brass
Black
Black/Brushed Face
Brass
White
White/Brushed Face
Housing
Finish
1 - Single Face
2 - Double Face
U - Universal Single/Double Face
-TR
Available Colors
BA -TR
Accessories
suffix to model)
Tamper resistent screws
VRS3
WGLX
WGLXC
WGLXE
(Order Separately)
Vandal resistant shield
Wire guard (Wall mount)
Wire guard (Ceiling mount)
Wire guard (End mount)
Dimensions
A
B
C
D
E
F
G
H
6.0”
4 1/4”
7 1/ 2” 8.0” 1 5/8” 12 1/8” 12 5/8” 1/ 2”
19 cm 20 cm 4.1 cm 30.8 cm 32.1 cm 1.3 cm 15.2 cm 10.8 cm
57
NYX
New York City LED Exit Sign
Features
AC Models
• Designed to meet New York City
specifications
• 20 gauge metal enclosure
• White or black finish
• Break-out directional chevrons
• Universal single/double face
models with eight inch letters
• Wall/ceiling/end mounting
• Dual voltage – 120/277VAC
• Bright and even illumination
• Long-life LED lamps
W
NE
Emergency Models
• Long life NiCad battery
• 90 minute emergency operation
• Test switch and AC-On indicator
• Environmentally coated, fully
automatic charger
• Temperature range: 0°C to 45°C
(32°F to 113°F)
• Listed to UL 924
Ordering Information
NYX
U R
W
E -FM
Options
Series
Operation
Faces
A - AC Only
E - Emergency
U - Universal single/double face
Housing
Finish
Letter Color
W
B
R - Red
Options
-FM
-AA
-TR
(Add
- White
- Black
suffix to model)
(1)(2)
Flasher module
Audible alarm module (1)(2)
Tamper resistant option (3)
Accessories
PMNYW
PMNYB
WGTW
(1) For use with emergency models only.
(2) -FM and -AA options may not be specified together.
(3) Provides two tamper-resistant locking screws.
(Order Separately)
Pendant mounting kit (white)
Pendant mounting kit (black)
Wire guard (Wall mount)
Dimensions
B*
A*
Power Consumption
AC Only Models
Emergency Models
120VAC
2.4W
3.4W
277VAC
2.4W
3.5W
* Wattage figures include LED lamps, transformers and electronics
power requirements.
58
C
* Add 1“ (2.5 cm) for mounting
canopy on ceiling or end mounted models
A
B
C
23/8”
101/2” 141/2”
26.7 cm 36.8 cm 6.0 cm
CMX
Chicago Low Profile Exit Sign
Features
All Models
• City of Chicago approved
• 22-gauge metal enclosure with
white or black finish
• Translucent glass diffuser
• Six-inch letters
• Full length, silkscreened
directional arrows
• Standard, incandescent AC lamps
(Fluorescent lamps optional)
• Standard 120 VAC (277 VAC
optional on AC models)
• Wall, end or ceiling mounting
• Downlighting aperture
Emergency Models
• Completely self-contained
emergency power pack
• 120-minute operation
• Fully automatic, solid-state charger
• Automatic, low-voltage
battery disconnect
• AC-On indicator and test switch
• Maintenance-free long-life leadacid battery
• Universal 120/277VAC operation
• UL Listed
W
NE
City of Chicago Approval No. 9823
Ordering Information
CMX S E
6 -AF
Options
Series
Faces
S - Single Face
D - Double Face
Exit Legend
Single face models
3 - “EXIT” (no arrows)
6 - “EXIT” (right arrow)
9 - “EXIT” (left arrow)
12 - “EXIT” (double arrow)
2 - “STAIRS” (no arrows)
5 - “STAIRS” (right arrow)
8 - “STAIRS” (left arrow)
11 - “STAIRS” (double arrow)
Operation
Blank - AC Only
E - Emergency
Options
-277V
-DC6
-DC12
-B
-FL
-FAP
-AF
-PH
(1)
(2)
(3)
(4)
(5)
(Add
suffix to model)
(1)
277 VAC operation
6 VDC emergency socket and lamp (1)
12 VDC emergency socket and lamp (1)
Black finish
7 watt fluorescent AC lamps
Fire alarm panel interface (2)(3)(4)
Audible flasher alarm (3)(4)(5)
Phosphorescent glass diffuser panel
For use with AC models only.
Operates with 24-volt AC or DC fire alarm panels.
-FAP and -AF options may not be specified together.
-FAP and -AF options not available with fluorescent lamp models.
-AF option for use with emergency models only.
Double face models
18 - “EXIT” (no arrows)
21 - “EXIT” (right/left arrow)
24 - “EXIT” (double arrow)
17 - “STAIRS” (no arrows)
20 - “STAIRS” (right/left arrow)
23 - “STAIRS” (double arrow)
Accessories
CKW
CKB
PMKW
PMKB
WGMLT
WGTW
WGTCE
VRS2
(Order Separately)
Canopy mounting kit (white)
Canopy mounting kit (black)
Pendant mounting kit (white)
Pendant mounting kit (black)
Wire guard (wall mount - AC models)
Wire guard (wall mount - emergency models)
Wire guard (ceiling/end mount - AC and
emergency models)
Vandal resistant shield (fits all models)
Dimensions
Power Consumption
AC Only Exits
Emergency Exits
Incandescent Models
Fluorescent Models
120/277VAC
40 watts
120/277VAC
18 watts
50 watts
28 watts
C
B
A
A
B
C
91/2”
141/2”
12 3/4”
32.4 cm 24.1 cm 36.8 cm
D
D
21/2”
6.4 cm
59
LE
Recessed Mounting Edge-Lit LED Exit Signs
Features
AC Models
• Ceiling, wall or end mounted
models for recessed installations
• Extruded aluminum construction
• Available in six color finishes
• Molded acrylic plaque
• Red and green letter models
• Clear, white or mirror
background
• Silkscreened chevron arrows
• Long life LED lamps
• Bright, even letter illumination
• Energy-saving operation
• Universal rough-in box
• Easy to install
• 120/277VAC, 60 Hz operation
Emergency Models
• Solid-state charger
• Maintenance-free NiCad battery
• Low voltage disconnect
• Test switch and AC-On light
• Available with Spectron® selftesting/self-diagnostic electronics
with time-delay relay
(TDR) standard
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL 924 Listed
Ordering Information
LE
C D
Series
R
C N
Directional
Arrows
LE - Recessed
mount
X - No arrows EXIT
R - Right arrow*
EXIT>
L - Left arrow*
C - L/R arrows**
Mounting
C - Ceiling mount
W - Wall mount
E - End mount
* Not for use with double
face models. Use “C” L/R
arrow designator
** Double face models only.
Provides reversible right
or left arrow indicator
Faces
S - Single
D - Double*
Options
(Add
* Not for use with wall mounted models
suffix to model)
E -FM
Operation
A - AC only
E - Emergency
Options
See “Options” section
Standard Plaque Backgrounds
Single face models = clear
Double face models = mirror
- Satin Aluminum
- White
See “Options” for alternate
- Chrome
backgrounds.
- Black
ccessories (Order Separately)
- Satin brass
Trim/Housing
Finish
N
W
C
B
S
Z - Dark Bronze
A
Letter Color
R - Red
G - Green
Satin Aluminum
White
Chrome
Black
Satin Brass
Dark Bronze
Wall mount model
Power Consumption
Single Double
Face Face
Red AC Only Models
2.2W
3.7W
Green AC Only Models
2.5W
4.4W
Red Emergency Models
Green Emergency Models
3.3W
3.6W
4.7W
5.2W
* Wattage figures include LED lamps, transformers and electronics
60
End mount model
Options
I
-XK
-W
-M
-8L
-2C
-FAP
-FM
-AF
-DC
-24K
(Add
suffix to model)
Spectron self-testing/self-diagnostic electronics
Recessed mount exit sign less rough-in kit (1)
White plaque background
Mirror plaque background (2)
8 inch letter plaque (red letters only) (10)(11)
2-circuit operation (3)(8)
Fire alarm panel interface (5)(7)(8)
Flasher module (4)(7)
Audible/flasher module (4)(7)
Remote DC operation (3)(6)(7)
220/240VAC, 60 Hz operation (9)
(1) Allows ordering of rough-in kit separately for recessed mount (LE) models.
See “Accessories”.
(2) For use with single face models only. Standard on double face models.
(3) For use with AC models only.
(4) For specification with emergency models only.
(5) Operates with 24-volt AC or DC fire alarm panels.
(6) For emergency illumination of sign from remote 6-24 VDC power sources.
(7) -FAP, -FM, -AF or -DC options may not be specified together.
(8) -2C and -FAP options may be specified together.
(9) Rough-in kit may not be ordered separately on models specified with -24K
option.
(10) LE exit models with 8” plaques registered under NYC-BEC Calendar Number
42135 for use in New York City.
(11) Single face LE exit signs specified with the -8L option are supplied without
backgrounds. Double face models specified with the -8L option are supplied
with mirror backgrounds.
Accessories
LE
(Order Separately)
URK
Universal rough-in kit (b)
URK2C Universal 2-circuit rough-in kit (a)(b)(c)
(a) For use with AC models only.
(b) Rough-in kit may not be ordered separately on models specified
with -24K option.
(c) Must be ordered in conjunction with -2C option on exit sign
To Order Rough-In Kit Separately
To order rough-in kit only for early installation, add
“-XK” option suffix to exit model number and order
“URK” or “URK2C” kit separately.
Universal Rough-In Kit
Dimensions
Rough-In Kit
Ceiling Mount Application
End Mount Application
Wall Mount Application
61
LES
Surface Mounting AC Edge-Lit LED Exit Signs
Features
• Long life LED lamps
• Bright, even letter illumination
• Energy-saving operation
• Easy to install
• 120/277VAC, 60 Hz operation
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL Listed
AC Models
• Ceiling, wall or end mounted
models for surface installations
• Extruded aluminum construction
• Available in six color finishes
• Molded acrylic plaque
• Red and green letter models
• Clear, white or mirror
background
• Silkscreened chevron arrows
Ordering Information
LES
C S
Series
C N
Directional
Arrows
LES - Surface
mount
Mounting
* Not for use with double
face models. Use “C” L/R
arrow designator
** Double face models only.
Provides reversible right
or left arrow indicator
Faces
Options
A -M
Operation
A - AC only
X - No arrows EXIT
R - Right arrow*
EXIT>
L - Left arrow*
C - L/R arrows**
C - Ceiling mount
W - Wall mount
E - End mount
S - Single
D - Double*
R
(Add
* Not for use with wall mounted models
suffix to model)
Options
See “Options” section
Standard Plaque Backgrounds
Single face models = clear
Double face models = mirror
- Satin aluminum
- White
See “Options” for alternate back- Chrome
grounds.
- Black
ccessories (Order Separately)
- Satin Brass
Trim/Housing
Finish
N
W
C
B
S
Z - Dark bronze
A
Letter Color
R - Red
G - Green
Satin Aluminum
White
Chrome
Black
Satin Brass
Dark Bronze
Power Consumption
Single Double
Face Face
Red AC Only Models
2.5W
4.0W
Green AC Only Models
2.6W
4.5W
* Wattage figures include LED lamps, transformers and electronics
power requirements.
62
End mount model
Options
-W
-M
-8L
(Add
LES
suffix to model)
White plaque background
Mirror plaque background (1)
8 inch letter plaque (red letters only) (2)(3)
(1) For use with single face models only. Standard on double
face models.
(2) LES exit models with 8” plaques registered under NYC-BEC Calendar
Number 42135 for use in New York City.
(3) Single face LES exit signs specified with the -8L option are supplied
without backgrounds. Double face models specified with the -8L option are supplied with mirror backgrounds.
Ceiling mount model
Dimensions
Ceiling Mount Application
Wall Mount Application
End Mount Application
63
NYE
New York City Recessed Edge-Lit Exit
Features
AC Models
• Designed to meet New York City
specifications
• Recessed ceiling or wall mount
models
• Extruded aluminum construction
• Available in two color finishes
• Acrylic plaque
• Eight-inch red letter models
• Clear, white or mirror
background
• Applique chevron arrows
• Long life LED lamps
W
NE
• Bright, even letter illumination
• Energy-saving operation
• Easy to install
• 120/277VAC, 60 Hz operation
Emergency Models
• Environmentally coated, fully
automatic charger
• Maintenance-free NiCad battery
• Low voltage disconnect
• Test switch and AC-On indicator
• Temperature range: 0°C to 45°C
(32°F to 113°F)
• Listed to UL 924
Ordering Information
NYE C
D
R N
E -W
Operation
Series
A - AC only
E - Emergency
NYE - Recessed
mount
Mounting
C - Ceiling
W - Wall
Trim/Housing
Finish
Options
See “Options” section
N - Satin aluminum
W - White
Faces
S - Single
D - Double*
* Not for use with wall mounted models
Letter Color
R - Red
Options
(Add suffix to model)
Options
(Add
(Order Separately)
suffix to model)
-LRBB
-W
-M
Recessed mount exit sign less rough-in backbox (1)
White exit face background
Mirrored exit face background
(1)
Allows ordering of rough-in backbox separately. See “Accessories”.
Accessories
Accessories
Dimensions
D
(Order Separately)
NYC-RBB Rough-in backbox
E
F
Power Consumption
120VAC
277VAC
AC Only Models
3.2W
3.2W
Emergency Models
4.0W
3.9W
B
A
* Wattage figures include LED lamps, transformers and electronics
C
A
B
C
D
E
F
G
H
131/2”
14”
165/8” 173/8” 193/16” 305/8” 23/4”
93/4”
24.8 cm 34.2 cm 35.6 cm 42.2 cm 44.1 cm 48.8 cm 77.8 cm 7.0 cm
64
NYES
New York City Surface Edge-Lit Exit
Features
AC Models
• Designed to meet New York
City specifications
• Surface mount design
• Wall, ceiling or end
mounted models
• Extruded aluminum construction
• Available in two color finishes
• Acrylic plaque
• Eight-inch red letter models
• Clear, white or
mirror background
• Applique chevron arrows
• Long life LED lamps
• Bright, even letter illumination
• Energy-saving operation
• Easy to install
• 120/277VAC, 60 Hz operation
Emergency Models
• Environmentally coated, fully
automatic charger
• Maintenance-free NiCad battery
• Low voltage disconnect
• Test switch and AC-On indicator
• Temperature range: 0°C to 45°C
(32°F to 113°F)
• Listed to UL 924
W
NE
Ordering Information
NYES C
D R
N
E
-W
Operation
Series
A - AC only
E - Emergency
NYES - Surface
mount
Mounting
C - Ceiling
W - Wall
E - End
Trim/Housing
Finish
Options
N - Satin aluminum
W - White
Faces
See “Options” section
S - Single
D - Double*
* Not for use with wall mounted models
Letter Color
R - Red
Options
(Add suffix to model)
Options
-W
-M
(Add
Accessories
(Order Separately)
Dimensions
suffix to model)
White exit face background
Mirrored exit face background
D
E
F
B
A
Power Consumption
120VAC
277VAC
AC Only Models
3.2W
3.2W
Emergency Models
4.0W
3.9W
* Wattage figures include LED lamps, transformers and electronics
C
A
B
C
D
E
F
14”
17”
165/8” 21/4”
10”
131/2”
25.4 cm 34.3 cm 35.6 cm 43.2 cm 42.2 cm 5.7 cm
65
DEX
Special Wording Incandescent Signs
Features
AC Models
• Thermoplastic housing
• Steel faceplate
• Polyester fiberglass special
wording open face diffuser
• Acrylic downlight lens
• Canopy for ceiling or end mount
• Universal directional chevron
arrow knockouts
• Tamper resistant screws supplied
• 120V standard
• AC illumination provided by two
145V, 15T6 incandescent lamps
• Suitable for damp locations (AC
models only)
Emergency Models
• Maintenance-free battery
• High impact housing
• Dual voltage – 120V/277VAC
• Two 6V, 3.7W DC lamps for
emergency operation
• Temperature range: 20°C to 30°C
(68°F to 86°F)
Ordering Information
DEX 1 EMFA R
Series
Background
Color
R – Red
G – Green
W – White
Faces
1 - Single
2 - Double
Special
Wording
Option No.
Operation
Letter
Color
Blank – AC-Only 120VAC
EMFA – Emergency 120/277VAC
R
G
W
B
Options
(Add
See table at
right
– Red
– Green
– White
– Blue
Option
No.*
-SW1
-SW2
-SW3
-SW4
-SW5
-SW6
-SW7
-SW8
-SW9
-SW10
-SW11
-SW12
-SW13
-SW14
-SW15
-SW16
-SW17
-SW18
-SW19
Description
TO EXIT
NOT AN EXIT
IN USE
XRAY IN USE
DARKROOM IN USE
CAUTION
DO NOT ENTER
TEST IN PROGRESS
ON AIR
AREA OF REFUGE
AREA OF REFUGE
(w/wheelchair symbol)
AREA OF RESCUE ASSISTANCE
AREA OF RESCUE ASSISTANCE
(w/wheelchair symbol)
ELEVATOR
RESTROOMS
MEN
MEN (w/symbol)
WOMEN
WOMEN (w/symbol) rder
Accessories
suffix to model)
Accessories
WG-MLT
WGLXC
WGTCE
PMEXW
PMEXB
VRS3
Special Wording Table
W -SW3
(O
Separately)
Other Special Wording models available. Consult Factory.
* To order special wording diffusers, add Option Number suffix
to model number. Ex: DEX1EMFARW-SW10
(Order Separately)
Wire guard (wall mount - all models)
Wire guard (ceiling mount - AC models only)
Wire guard (end mount - all models)
12” pendant stem and canopy kit – white
12” pendant stem and canopy kit – black
Vandal resistant shield
Dimensions
11” (279 mm)
5”
(127 mm)
CANOPY
1
/2”
(13 mm)
4 3/4”
(120 mm)
Power Pack
11” (279 mm)
2 1/2”
(64 mm)
8”
(204 mm)
7 1/2”
(191 mm)
5 1/2”
(140 mm)
11 1/2” (292 mm)
66
3 1/4”
(83 mm)
(EMFA models)
3
2 /8”
(60 mm)
1
/2”
(13 mm)
SlimLite Series
CV Series
CVEC Series
CV3 Series
CVT Series
CVD Series
CVER Series
Fixed Lens Emergency Lights................................................... 68
Emergency Lights................................................................... 69
High Capacity Emergency Lights.............................................. 70
LED Exit Signs..................................................................................71
Tandem Units. ....................................................................... 72
Diecast LED Exit Signs......................................................................73
67
Recessed Mounting Edge-Lit LED Exit Signs...................................74
SlimLite
Contemporary Emergency Light
Features
• Easy to install
• Sleek, low profile design
• Flame rated, UV stable
thermoplastic housing
• Bright white finish
• 6 volt, T-5 incandescent lamps
• Acrylic fresnel lens provides a
focused beam pattern
• Adjustable lamp socket
• Maintenance-free battery
• Universal 120/277VAC operation
12W
• Fully-automatic, temperature-
compensated, solid-state charger
• Reverse polarity and short circuit
protection
• AC lockout
• Low-voltage battery disconnect
• Test switch and AC-On light
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• Meets ADA specifications
• UL 924 Listed
Ordering Information
Standard Model
SL1
Voltmeter Model
SL1-V
Also available in black finish
Options
(Add
suffix
catalogto
number)
O
ptions
(A
dd to
suffix
model)
-B
-6H
Accessories
(Order Separately)
Vandal resistant shield
VRS
WGLZ Wire guard
Black housing
6 watt halogen lamps
Product Selector
Options (Add suffix to model)
Accessories
Electrical
(Order Separately)
Base Output Watts
AC Input
Catalog Output
1.5
2
3
4 Standard Remote
Number
Volts
Hours Hours Hours Hours
Volts
Amps
Watts Lamp Capability
SL1, SL1-V
6
12.0
--
--
-
120
.050
6.0
277
.020
6.0
5.4W
No
Dimensions
5 1/8”
(13 cm)
TEST/ESSAI
CHARGE
11 3/4”
(30 cm)
68
2 1/4” (5.7cm)
Designer Emergency Light
Features
• Fast, easy installation
• Snap-together design
• Compact, low-profile style
• Injection molded high impact, UV
stabilized thermoplastic
• White finish
• Standard and damp location
models
• Remote capacity models
• High output incandescent lamps
• Maintenance-free battery
• Dual voltage – 120/277VAC
• Fully automatic charger
• Automatic low-voltage battery
disconnect and transformer
isolation protection
• Universal mounting plate
• Test switch and LED AC-On light
• Temperature range: 20°C to 30°C
(68°F to 86°F)
Damp location models: 10°C to 40°C
(50°F to 104°F)
• UL 924 Listed
Ordering Information
Standard
Models: Information
CV2 (6V, 12W)
CV3
(6V, 18W)
Ordering
Example:
EDS4-EV1
Damp Location Models:
Options
-V
CV2D (6V, 12W)
(Add
CV
11W to 30W
CV3D (6V, 18W)
W
NE
CV5 (6V, 30W)
CV5D (6V, 30W)
Accessories
suffix to model)
Voltmeter
(Order Separately)
SRHSW0605 Matching remote head - single (white)
SRHDW0605 Matching remote head - twin (white)
OMSSB0605 Single outdoor lighting head (black)
OMSDB0605 Twin outdoor lighting head (black)
PMLZTW
Pendant mounting kit (white) (a)
PMLZTB Pendant mounting kit (black) (a)
WGEL
Wire guard
(a) Not available for use with CV5 and CV5D models.
Options
(Add
Matching
remote head
Accessories
suffix to model)
Outdoor
lighting head
(Order Separately)
Product Selector
Base
Catalog Output
Number
Volts 1.5 Hrs.
Electrical
Output Watts
2 Hrs.
3 Hrs.
4 Hrs.
Input Amps Input Watts Standard Remote
120V 277V 120/277V Lamp
Capability
CV2
6
12
--
--
--
.040
.020
4.0
5.4W
No
CV3
6
18
13
--
--
.040
.020
4.0
5.4W
Yes
CV5
6
30
22
15
12
.130
.060
14.0
5.4W
Yes
CV2D
6
11
--
--
--
.040
.020
4.0
5.4W
No
CV3D
CV5D
6
6
17
27
12
20
--
13
--
--
.040
.130
.020
.060
4.0
14.0
5.4W
5.4W
Yes
Yes
Photometrics
Dimensions
Horizontal Isofootcandle Distribution
15 7/8”-Min.
19 3/4”-Max.
4 3/4”-Min.
6 3/4”-Max.
(40.3 cm)-Min.
(50.2 cm)-Max.
(12.1 cm)-Min.
(17.1 cm)-Max.
6 Volt, 5.4 Watt SBT Lamp
5 3/8”
(13.7 cm)
69
CVEC
Commercial Emergency Light
Features
• Injection molded high impact,
UV stabilized thermoplastic
• Standard white housing
• T-5 incandescent lamps
• Lampheads may be top or side
mounted
• Most models capable of powering
remote lampheads
• Maintenance-free battery
• Dual voltage – 120/277VAC
• Automatic low voltage disconnect
• Thermally compensated charger
W
NE
15W to 100W
• Regulated charge voltage
• Automatic low voltage disconnect
• Reverse polarity protection
• Filtered charger output
• Universal wall mounting plate
• Short circuit protection
• AC lockout
• Test switch and AC-On light
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL 924 Listed
Ordering Information
Standard Models:
Options
-V
CVEC15
(Add
CVEC30
CVEC 50
CVEC50-12V
CVEC100-12V
Accessories
suffix to model)
Voltmeter
(Order Separately)
Wire guard (a)
Wire guard (b)
Matching 6-volt remote head - single
Matching 6-volt remote head - twin
Matching 12-volt remote head - single
Matching 12-volt remote head - twin
40G
41G
SRHSW0607
SRHDW0607
SRHSW1207
SRHDW1207
(a) For top mounted heads on CVEC 15 and 30 watt models
(b) For top mounted heads on CVEC 50 and 100 watt models and side mounted
heads on CVEC 15 and 30 watt models.
Options
(Add
Accessories
suffix to model)
(Order Separately)
Product Selector
Electrical
Standard Output
Output Watts
Input Amps Input Watts Standard Remote
Models Volts 1.5 Hrs. 2 Hrs. 3 Hrs. 4 Hrs. 120V 277V 120 277V Lamp
Capability
CVEC15
6
15
--
--
--
.07
.03
8.4
8.8
7.2W
No
CVEC30
6
30
22
15
12
.07
.03
8.4
8.8
7.2W
Yes
CVEC50
6
50
38
25
20
.17
.08
20
20
7.2W
Yes
CVEC50-12V
12
50
38
25
20
.11
.05
13
14
9.0W
Yes
CVEC100-12V
12
100
76
54
44
.32
.14
39
28
9.0W
Yes
Photometrics
Horizontal Isofootcandle Distribution
6 Volt, 7.2 Watt SBT Lamp
70
12 Volt, 7.2 Watt SBT Lamp
Dimensions
15 and 30W Models
50 and 100W Models
CV3
Thermoplastic LED Exit Sign
Features
• Damp location listed
• 120/277VAC, 60 Hz operation
Emergency Models
• Solid-state charger with low
voltage disconnect
• Maintenance-free NiCad battery
• 2 hour emergency operation
• Test switch and AC-On light
• Temperature range: 0°C to 40°C
(32°F to 104°F)
• UL 924 Listed
All Models
• UV-stable thermoplastic housing
• Compact, low-profile design
• Easy to install
• Long-life LED lamps
• Bright, even illumination
• Red and green letters
• Universal single/double face
• White finish
• Push-in wiring connectors
• Universal end/ceiling/wall mount
• Universal snap-in,
chevron arrows
W
NE
Ordering Information
CV
3 R
E
W -2C
Series
Options
Housing
Finish
Faces
3 - Universal Single/Double Face
W - White
Letter Color
Options
Operation
R - Red
G - Green
A - AC Only
E - Emergency
Options
(Add
-2C
-DC
suffix to model)
Dimensions
7”
5 3/16”
(17.8 cm)
(13.2 cm)
(Add
suffix to model)
2-circuit operation (1)(3)
Remote DC operation (1)(2)(3)
(1) For use with AC models only.
(2) For emergency illumination of sign from remote 6-24 VDC
power sources.
eparately
(3) -2C and -DC options may not be specified rder
together.
Accessories
(O
Accessories
(Order Separately)
PMLXW
WGLX
WG-MLT
WGLXC
WGLXE
VRS3
S
)
Pendant mounting kit (white)
Wire guard (Wall mount)
Wire guard (Wall mount)
Wire guard (Ceiling mount)
Wire guard (End mount)
Vandal resistant shield
9 3/4”
(24.8 cm)
9”
(22.8 cm)
Power Consumption
13”
(33.0 cm)
1 3/4”
(4.4 cm)
120VAC
277VAC
Red AC Only Models
2.7 watts
2.7 watts
Green AC Only Models
2.3 watts
2.3 watts
Red Emergency Models
3.8 watts
3.8 watts
Green Emergency Models
3.5 watts
3.5 watts
Power factor, average: .8 (lagging)
71
CVT
Thermoplastic Tandem Unit
Features
• Factory assembled emergency
unit/LED exit sign
• UV-stable thermoplastic housing
• High-output lighting heads
• White finish
• Damp location listed
models available
• 120/277VAC, 60 Hz operation
• Solid-state charger with lowvoltage disconnect
• Maintenance-free battery
• Test switch and LED AC-On light
W
NE
• Long-life LED lamps
• Bright, even illumination
• Universal single/double face
• Red and green letter models
• Snap-in, chevron arrows
• Ceiling or wall mounting
• Temperature range: 20°C to 30°C
(68°F to 86°F)
Damp location models: 10°C to 40°C
(50°F to 104°F)
• UL 924 Listed
Ordering Information
CVT 3 R
W
5 D
Series
Faces
3 - Universal Single or Double
Blank - Standard model
- Damp location model*
D
* Only available on 3-head models
W - White
Letter Color
Remote Heads
R - Red
G - Green
Blank - No remote capability
- Operates one additional
3
5.4 watt remote head
5
- Operates up to three
additional 5.4 watt
remote heads
Options
Input Amps
Input Watts
Application
Housing
Finish
(Add
suffix to model)
120VAC 277VAC
.05
.02
5.0
5.0
Accessories
(Order Separately)
SRHSW0605 Matching remote head - single (white)
SRHDW0605 Matching remote head - twin (white)
ccessories (Order Separately)
OMSSB0605 Single outdoor lighting head (black)
OMSDB0605 Twin outdoor lighting head (black)
PMLZTW Pendant mounting kit (white) (a)
WGTW Wire guard (Wall mount)
WGTCE Wire guard (Ceiling mount)
A
(a) Not available for use with 5-head models
Dimensions
15 7/8”-Min.
19 3/4”-Max.
4 3/4”-Min.
6 3/4”-Max.
(40.3 cm)-Min.
(50.2 cm)-Max.
(12.1 cm)-Min.
(17.1 cm)-Max.
Photometrics
Horizontal Isofootcandle Distribution
6 Volt, 5.4 Watt SBT Lamp
14 3/8”
(36.5 cm)
9”
(22.8 cm)
13”
(33.0 cm)
1 3/4”
(4.4 cm)
72
CVD
Cast Aluminum LED Exit Sign
Features
AC Models
• All diecast aluminum construction
• Soft edges and corners
• White and black with brushed
face finishes
• Break-out directional chevrons
• Universal mounting KO pattern
• Back/ceiling/end mounting
• Dual voltage – 120/277VAC
• Bright and even illumination
• Long-life LED lamps
Emergency Models
• Long life NiCad battery
• 90 minute emergency operation
• Test switch and AC-On indicator
• Reverse polarity, short circuit and
brownout protection
• Thermally compensated charger
• AC lockout
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• UL 924 Listed
W
NE
Ordering Information
CVD 1 R
Series
A BN -2C
Options
Operation
A - AC Only
E - Emergency
Faces
1 - Single
2 - Double
-DC
-2C
Letter Color
(Add
suffix to model)
Remote DC operation (1)
2-circuit operation (1)
(1) For use with AC models only.
Housing
Finish
W - White
BN - Black with brushed face
R - Red
G - Green
Options
Accessories
(Order Separately)
121/2”
Options
(Add
suffix to model)
PMCW
Pendant mounting kit (white)
PMCB
121/2” Pendant mounting kit (black)
WGLX
Wire guard (Wall mount)
WG-MLT Wire guard (Wall mount)
ccessories
(Order
WGLXC
Wire guard (Ceiling
mount) Separately)
WGLXE
Wire guard (End mount)
A
Dimensions
Power Consumption
9 1/8”
(23 cm)
10”
(25.5 cm)
11 3/4” (30 cm)
12 5/8” (32 cm)
1 5/8” (4.14 cm)
Red AC Only Models:
Green AC Only Models:
Red Emergency Models:
Green Emergency Models:
120VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts
277VAC
2.6 watts
2.1 watts
3.8 watts
3.5 watts
*Wattage figures include LED lamps, transformer and electronics power
requirements. LED lamp assemblies (red or green) consume less than 1 watt.
Power factor, average: .8 (lagging)
73
CVER
Recessed Mount Edge-Lit LED Exit Sign
Features
AC Models
• Ceiling mounted models for
recessed installation
• Metal construction
• Available in two color finishes
• Clear acrylic plaque
• Red and green letter models
• Applique chevron arrows
• Long life LED lamps
• Bright, even letter illumination
• Energy-saving operation
W
NE
Ordering Information
CVER 1 R
N
• Easy to install
• 120/277VAC, 60 Hz operation
Emergency Models
• Fully automatic charger
• Maintenance-free NiCad battery
• Low voltage disconnect
• Test switch and AC-On light
• Temperature range: 20°C to 30°C
(68°F to 86°F)
• ETL Listed
Availability To Be Announced
E
Operation
Series
A - AC only
E - Emergency
CVER - Recessed
mount
Faces
1 - Single
2 - Double*
* Provided standard with mirror
background.
Fully-adjustable universal mounting bar system
allows installations in standard construction
and suspended ceiling applications.
Trim/Housing
Finish
Letter Color
N - Satin aluminum
W - White
R - Red
G - Green
Options
(Add
suffix to model)
Accessories
(Order Separately)
Dimensions
D
E
F
Field installable chevrons provide for all possible
directional arrow requirements.
Power
Consumption
Red AC Only Models
Green AC Only Models
Red Emergency Models
Green Emergency Models
120VAC
2.2W
2.5W
3.3W
3.6W
277VAC
3.7W
4.4W
4.7W
5.2W
* Wattage figures include LED lamps, transformers and electronics
power requirements.
74
A
C
A
7 7/8”
B
11”
C
12 5/8”
D
15”
E
14 3/8”
F
4 1/8”
20.0 cm 27.9 cm 32.1 cm 38.1 cm 36.5 cm 10.5 cm
B
Features
Ordering Information
Options
(Add
suffix to model)
Accessories
(Order Separately)
Remote Heads and Fixtures . ..........................................................76 to 78
Lamp Selector Guide .......................................................................................... 79
Voltage Drop Tables ................................................................................ 80
Unit Accessories . ................................................................................................. 81
National Electric Code ................................................................................. 82, 83
NFPA 101 Life Safety Code . ....................................................................... 84, 85
Limited Warranty ................................................................................................ 86
75
Remote Heads and Fixtures
Standard Remote
Lighting Heads
SRH Series
Injection molded thermoplastic lamphead/round mounting
plate assemblies. Mounts to 31/2” octagonal or single gang
boxes. For use with most commercial or industrial emergency fixtures. Standard finish is available in white or black.
Single and twin lamp fixtures with a choice of incandescent
or halogen PAR 36 lamps.
Lamp photometrics and IES files available on the web at www.dual-lite.com
White
Black
Halogen PAR 36
Incandescent PAR 36
Sealed Beam Sealed Beam
Single Head With Twin Head With Single Head With Twin Head With Lamp Lamp Lamp
Mounting Plate
Mounting Plate
Mounting Plate
Mounting Plate
Voltage Wattage Part No.
SRHSW0605
SRHDW0605
SRHSB0605
SRHDB0605
6
5.4
0110258*
SRHSW0607
SRHDW0607
SRHSB0607
SRHDB0607
6
7.2
0110213*
SRHSW0618
SRHDW0618
SRHSB0618
SRHDB0618
6
18
0110127
SRHSW0625
SRHDW0625
SRHSB0625
SRHDB0625
6
25
0110041
SRHSW1207
SRHDW1207
SRHSB1207
SRHDB1207
12
7.2
0110289*
SRHSW1218
SRHDW1218
SRHSB1218
SRHDB1218
12
18
0110128
SRHSW1225
SRHDW1225
SRHSB1225
SRHDB1225
12
25
0110132
SRHSW1235
SRHDW1235
SRHSB1235
SRHDB1235
12
35
0110233
SRHSW2409
SRHDW2409
SRHSB2409
SRHDB2409
24
9
0110230*
SRHSW0608
SRHDW0608
SRHSB0608
SRHDB0608
6
8
0110162
SRHSW0612
SRHDW0612
SRHSB0612
SRHDB0612
6
12
0110159
SRHSW0620
SRHDW0620
SRHSB0620
SRHDB0620
6
20
0110157
SRHSW1208
SRHDW1208
SRHSB1208
SRHDB1208
12
8
0110189
SRHSW1212
SRHDW1212
SRHSB1212
SRHDB1212
12
12
0110190
* Sealed Beam type lamp
Outdoor Remote Lighting Heads
OMS Series
Outdoor aluminum spot with sealed lamp and swivel
assembly. Furnished with round gasketed aluminum
mounting plate. Mounts to 31⁄ 2” octagonal boxes.
Lamp photometrics and IES files available on the web at www.dual-lite.com
White
Black
Halogen PAR 36
Incandescent PAR 36
Sealed Beam Sealed Beam
Single Head With Twin Head With Single Head With Twin Head With Lamp Lamp Lamp
Mounting Plate
Mounting Plate
Mounting Plate
Mounting Plate
OMSSW0605
OMSDW0605
OMSSB0605
OMSDB0605
6
5.4
0110258*
OMSSW0607
OMSDW0607
OMSSB0607
OMSDB0607
6
7.2
0110213*
OMSSW0618
OMSDW0618
OMSSB0618
OMSDB0618
6
18
0110127
OMSSW0625
OMSDW0625
OMSSB0625
OMSDB0625
6
25
0110041
OMSSW1207
OMSDW1207
OMSSB1207
OMSDB1207
12
7.2
0110289*
OMSSW1218
OMSDW1218
OMSSB1218
OMSDB1218
12
18
0110128
OMSSW1225
OMSDW1225
OMSSB1225
OMSDB1225
12
25
0110132
OMSSW1235
OMSDW1235
OMSSB1235
OMSDB1235
12
35
0110233
OMSSW0608
OMSDW0608
OMSSB0608
OMSDB0608
6
8
0110162
OMSSW0612
OMSDW0612
OMSSB0612
OMSDB0612
6
12
0110159
OMSSW0620
OMSDW0620
OMSSB0620
OMSDB0620
6
20
0110157
OMSSW1208
OMSDW1208
OMSSB1208
OMSDB1208
12
8
0110189
OMSSW1212
OMSDW1212
OMSSB1212
OMSDB1212
12
12
0110190
* Sealed Beam type lamp
76
Voltage Wattage Part No.
All Metal Remote
Lighting Heads
Remote Heads and Fixtures
AHD
Stamped aluminum housing with metal
swivel. Standard finish available in white
or black. Choice of incandescent or
halogen PAR 36 lamps.
Lamp photometrics and IES files available on the web at www.dual-lite.com
White
Black
Single Head With Twin Head With Single Head With Twin Head With Lamp Lamp Lamp
Halogen PAR 36
Sealed Beam
Incandescent PAR 36
Sealed Beam
Mounting Plate
Mounting Plate
Mounting Plate
Mounting Plate
Voltage Wattage Part No.
AHDSW0605
AHDDW0605
AHDSB0605
AHDDB0605
6
5.4
0110258*
AHDSW0607
AHDDW0607
AHDSB0607
AHDDB0607
6
7.2
0110213*
AHDSW0618
AHDDW0618
AHDSB0618
AHDDB0618
6
18
0110127
AHDSW0625
AHDDW0625
AHDSB0625
AHDDB0625
6
25
0110041
AHDSW1207
AHDDW1207
AHDSB1207
AHDDB1207
12
7.2
0110289*
AHDSW1218
AHDDW1218
AHDSB1218
AHDDB1218
12
18
0110128
AHDSW1225
AHDDW1225
AHDSB1225
AHDDB1225
12
25
0110132
AHDSW1235
AHDDW1235
AHDSB1235
AHDDB1235
12
35
0110233
AHDSW2407
AHDDW2407
AHDSB2407
AHDDB2407
24
7.2
0110212*
AHDSW2413
AHDDW2413
AHDSB2413
AHDDB2413
24
13
0110009*
AHDSW2418
AHDDW2418
AHDSB2418
AHDDB2418
24
18
0110010*
AHDSW2428
AHDDW2428
AHDSB2428
AHDDB2428
24
28
0110011*
AHDSWLV30
AHDDWLV30
AHDSBLV30
AHDDBLV30
120
30
0110021*
AHDSW0608
AHDDW0608
AHDSB0608
AHDDB0608
6
8
0110162
AHDSW0612 (1)
AHDDW0612 (1)
AHDSB0612
AHDDB0612
6
12
0110159
AHDSW0620
AHDDW0620
AHDSB0620
AHDDB0620
6
20
0110157
AHDSW1208
AHDDW1208
AHDSB1208
AHDDB1208
12
8
0110189
AHDSB1212
AHDDB1212
12
12
0110190
(1)
AHDSW1212
(1)
AHDDW1212
* Sealed Beam type lamp
(1) Matches LM City of Chicago models.
Lamp photometrics and IES files available on the web at www.dual-lite.com
GNX Series
Moisture resistant thermoplastic head in black finish with
coated lamp terminals and
sealed swivel assembly. Furnished with mounting plate.
Available with a choice of
incandescent or halogen PAR
36 lamps. Matches N4X series
units.
Available with shatter containment option.
Add “-L” to model number for Sealed Beam
Lamps PAR36 only. Example: GNXSB0625-L
N4X Remote Head Models Lamp Lamp Lamp
Single Twin
Volts Watts Part No.
GNXSB0605
GNXDB0605
6
5.4
0110258*
GNXSB0607
GNXDB0607
6
7.2
0110213*
GNXSB0618
GNXDB0618
6
18
0110127
GNXSB0625
GNXDB0625
6
25
0110041
GNXSB1209
GNXDB1209
12
9
0110202*
GNXSB1218
GNXDB1218
12
18
0110128
GNXSB1225
GNXDB1225
12
25
0110132
GNXSB1235
GNXDB1235
12
35
0110233
GNXSB0608
GNXDB0608
6
8
0110162
GNXSB0612
GNXDB0612
6
12
0110159
GNXSB0620
GNXDB0620
6
20
0110157
GNXSB1208
GNXDB1208
12
8
0110189
GNXSB1212
GNXDB1212
12
12
0110190
Halogen PAR 36 Incandescent PAR 36
Sealed Beam
Sealed Beam
Environmental
Lighting Head
* Sealed Beam Type lamp
77
Remote Heads and Fixtures
RERS
Injection molded housing. Surface mounted. Semi-recessed or
recessed mounting available with
kit. Black box, white trim. Single
(RERS-1) and twin (RERS-2) lamp
models. Dimensions and mounting
kits same as Lite2.
Square
Catalog No.
Recessed
Rectangle
Catalog No.
Recessed
Eyeball
Lamp Part No.
124R-0628
124R-1228
0110003
0110007
Lamp Part No.
RERS-1-0609
0110163
RERS-2-0607
0110213
F-SRM Semi-recessed mounting kit
-FRM
124R
Recessed mounted fixture with
frosted lens. White trim.
Dimensions: 83⁄16” x 41⁄2” x 4”.
Gimbal
Fully-recessed option
133
Adjustable to 42° and rotated
through 358°. White standard,
other finishes upon request.
Dimensions: Trim ring: 47⁄ 8” dia.
Back box: 43⁄ 16” deep x 4” dia.
Catalog No.
133-0618
133-1218
122
Adjustable (60° max.) recessed
mounted fixture. Matte white trim.
Dimensions: 81⁄ 2” dia. x 41⁄ 2”.
Incandescent PAR 36 Lamp Models
Catalog No.
Lamp Part no.
122SB-0625
122SB-1225
0110041
0110132
Halogen PAR 36 Lamp Models
Catalog No
Lamp Part No.
122SB-T-0608
122SB-T-0612
122SB-T-0620
122SB-T-1208
122SB-T-1212
Lamp Part No.
0110002
0110006
0110162
0110159
0110157
0110189
0110190
Bayonet Base Lamp Models
Catalog No.
Lamp Part No.
122-2407
122-2413
122-2418
122-2428
LZ Series Matching
Remote Lighting Heads
0110212
0110009
0110010
0110011
Single Remote Single Remote Lamp Lamp Lamp
LZR
Head -White
Architectural/commercial
design. High performance MR-16
halogen lamps standard. Mounts to
standard electrical boxes using
universal mounting plate provided.
Fixture housing mounts to back plate
in a choice of four mounting
positions. Housings secured using
locking screws provided.
Head - Black
Volts Watts Part No.
LZRSW0605
LZRSB0605
6
5
0110256
LZRSW0610
LZRSB0610
6
10
0110261
LZRSW1205
LZRSB1205
12
5
0110263
LZRSW1210
LZRSB1210
12
10
0110264
Twin Remote Twin Remote Lamp Lamp Lamp
Head -White Head - Black Volts Watts Part No.
LZRDW0605
LZRDB0605
6
5
0110256
LZRDW0610
LZRDB0610
6
10
0110261
LZRDW1205
LZRDB1205
12
5
0110263
LZRDW1210
LZRDB1210
12
10
0110264
Lamp photometrics and IES files available on the web at www.dual-lite.com
IPS Series Matching
Remote Lighting Heads
C1D2R/C1D2TR
Suitable for wet and damp location
applications. Rated for NEC Class I,
Division 2, Groups B, C and D as well
as Class I, Zone 2, Group IIB + H2
environments. Black housing and
head assemblies. Single (C1D2R)
and twin (C1D2TR) head models.
Model Numbers
Lamps * Single Head Twin Head
Volts Watts Hub Left Side(1)(2) Hub Left Side(1)(2)
6 8
C1D2R-6V8W C1D2TR-6V8W
6 12 C1D2R-6V12W C1D2TR-6V12W
12 8
C1D2R-12V8W C1D2TR-12V8W
12 12 C1D2R-12V12W C1D2TR-12V12W
3R Listed
* PAR 36 Halogen sealed beam lamps.
(1) Hub Right Side - add “R” to end of model number. Example C1D2R-6V8WR.
(2) Hubs Both Sides - add “F” to end of model number. Example C1D2R-
Consult factory for additional voltage and wattage configurations for remote fixtures.
78
Lamp Selector Guide
MR16 Lamps
Dual-Lite
Part Number Lamp Number Lamp Type Lamp Volts Lamp Watts
0110256
MR16 6V5W
Halogen
6
5
0110261
MR16 6V10W
Halogen
6
10
0110263
MR16 12V5W
Halogen
12
5
0110264
MR16 12V10W
Halogen
12
10
PAR 36 Sealed Beam Lamps
Dual-Lite
Part Number Lamp Number Lamp Type Lamp Volts Lamp Watts
0110127
4014
Incandescent
6
18
Incandescent
6
25
0110041
4510
Incandescent
12
18
0110128
4414
0110132
4446
Incandescent
12
25
0110233
4411
Incandescent
12
35
Halogen
6
8
0110162
H7551
Halogen
6
12
0110159
H7553
Halogen
6
20
0110157
H7554
0110189
H7555
Halogen
12
8
0110190
H7557
Halogen
12
12
Double Contact Bayonet Base Lamps
Dual-Lite
Part Number Lamp Number Lamp Type Lamp Volts Lamp Watts
0110212
304
Incandescent
24
7.2
0110009
1692
Incandescent
24
13
0110010
308
Incandescent
24
18
0110011
310
Incandescent
24
28
0110021
30S11/93
Incandescent
125
30
Wedge Base Lamps
Dual-Lite
Part Number Lamp Number Lamp Type Lamp Volts Lamp Watts
0110258
939
Incandescent
6
5.4
0110213
927
Incandescent
6
7.2
KB-AN
Incandescent
12
7.2
0110289
915
Incandescent
12
9
0110202
0110230
-
Incandescent
24
9
79
Voltage Drop Tables
The National Electrical Code limits voltage drop to a maximum of 5% of nominal. Circuit runs must be of sufficient
capacity to maintain operating voltage when remote fixtures and/or exit signs are connected to the emergency lighting
TABLE A - Important Electrical Installation Information
12 Volt System
6 Volt System
Wire Gauge
Wire Gauge
Total Watts
#12
#10
#8
#6 Total Watts
#12
#10
#8
on Wire Run Max. Length of Wire Run (Feet)
on Wire Run Max. Length of Wire Run (Feet)
#6
379
325
284
227
178
162
134
119
114
108
95
86
76
63
53
44
43
29
21
17
14
12
10
10
9
6
7
8
10
12
14
16
18
20
21
24
25
30
35
40
48
50
75
100
125
150
175
200
225
250
378
324
283
226
178
162
133
119
113
108
89
86
75
65
53
44
43
28
21
17
14
12
10
10
9
600
515
450
360
283
257
212
189
180
171
141
136
120
103
85
70
68
45
34
27
23
19
16
16
14
955
818
716
570
450
409
338
300
286
273
225
216
190
164
135
112
108
72
54
43
36
31
27
25
22
1518
1301
1138
910
715
650
538
477
455
434
357
344
303
260
214
178
172
115
86
69
57
49
42
40
36
6
7
8
10
12
14
16
18
20
21
24
25
30
35
40
48
50
75
100
125
150
175
200
225
250
94
81
70
56
44
40
33
30
28
27
24
21
19
15
13
11
11
7
5
4
3
3
2
2
2
150
129
112
90
70
64
53
47
45
43
38
34
30
25
21
17
17
11
8
7
5
5
4
4
3
238
204
179
143
112
102
84
75
71
68
60
54
48
39
33
28
27
18
14
11
9
8
6
6
5
Values not shown in Table A may be calculated using the following formulas:
Length (Feet) =
I. Maximum
Example:
Table B Constant Value
Maximum Load (Watts)
Find the maximum circuit length for #8 wire on a 24 volt system with an 80 watt load.
Maximum Length (Feet) = 21613 ÷ 80 = 270 feet.
Table B Constant Value
II. Maximum Load (Watts) =
Maximum Length (Feet)
Example:
Find the maximum circuit load for 540 feet of #12 wire on a 32 volt system.
Maximum Load (Watts) = 15197 ÷ 540 = 28 watts.
Table B
Constant Values per Voltage System Wire Size (Maximum Voltage Drop 5%)
System
Wire Size
#12
Constant
534
System
Wire Size
#12
Constant
6 Volt
#10
#8
849
#10
#6
350
#12
#10
#8
2148
32 Volt
#8
#6
2137
#4
#12
3397
#10
5403
48 Volt
#8
#6
12 Volt
#4
8590
#6
13660
#4
#12
#12
#10
#8
8548
#10
13588
#6
21613
110 Volt
#8
#6
24 Volt
#4
34363
54641
#4
#2
15197 24157 38423 61090 97140 34193 54353 86452 137454 218565 179575 285450 454025 721875 1147850 1824900
Uniform Loads
The maximum circuit length data in Table A (and derived from Table B) assumes that 100% of the load is concentrated at the end of the run. If
equally sized loads can be equally spaced along the run, maximum circuit length can be increased by the multipliers shown in Table C.
Table C
Multipliers for Equally Sized, Equally Spaced Loads (Maximum Voltage Drop 5%)
Number of Fixtures
Multiply Distance By
80
2
3
4
5
6
7
8
9
10
n
1.333
1.500
1.600
1.670
1.714
1.750
1.777
1.800
1.818
2n/(n+1)
Unit Accessories
Wire Guards
Mounting Brackets and Shelves
Offered for most Dual-Lite emergency lights and exits.
Constructed of heavy gauge steel, all wire guards are
standard with chrome plating. Order as separate line item.
For mounting of AS Series industrial emergency lighting
units.
WB-6
6000
L-6 & L-12-S
mounting BrACkets And sHelVes
Wire guArds
CAt. no.
WGLZ
S6WG
WGEL
40G
41G
WGLX
WGLXC
WGLXE
WGTW
WGTCE
WG-MLT
CAt. no.
WB-6
6000
L-6
L-12-S
for use WitH
All enclosure 1 & 2 models
Enclosure 1 models only
Enclosure 1 models only
Enclosure 2 models only
type
Bracket
Shelf
Shelf
Shelf
dimensions
-11” H x 14” L x 81⁄8” D
11” H x 14” L x 81⁄8” D
11” H x 16” L x 81⁄8” D
for use WitH
LZ Series (except High-Capacity models)
Remote heads
EZ-2, EZ-2R and LZ High-Capacity Series,
Remote heads, CV Series
dimensions (inside)
61⁄4” H x 14” L x 41⁄4” D
8” H x 8” L x 8” D
8” H x 20” L x 8” D
LM Series with top mounted heads,
AS Series (enclosure 1 models), N4X Series,
CVEC Series (15 and 30 watt models) and
NYXC tandem units
181⁄2” H x 20” L x 12” D
AS Series (enclosure 2 models),
Delite Cylinder Series, SMC exits and
CVEC Series (50 and 100 watt models)
EXT-122-EM-K, Wall mount LX, LED and
Sempra Series exits, Wall Mount CV3 Series
Ceiling mount LX, LED, Sempra and
CV3 Series exits
21” H x 23” L x 15” D
Vandal Resistant Shields
10” H x 14” L x 21⁄4” D
For protection against vandalism or accidental damage.
Prevents tampering with mountings and lamps.
End mount LX, LED and Sempra, CV3 and
CVD Series exits
Wall mount LT, Freedom LED, CVT
NYDC and NYX Series exits
101⁄ 2” H x 141⁄ 2” L x 31⁄ 2” D
Ceiling or end mount LT, CVD, CVT
and Freedom LED Series exits. Ceiling
mount NYDC and NYX Series exits
Lite2 Series, Wall mount LX, DK, Sempra
DEX, CV3 and CVD Series exits
20” H x 167⁄ 8” L x 8” D
101⁄4” H x 133⁄4” L x 31⁄ 2” D
16” H x 20” L x 77⁄ 8” D
115⁄ 8” H x 135⁄ 8” L x 7” D
VRS/VRS-4X
VRS2
VRS3
VAndAl sHields
CAt. no.
for use WitH
VRS
EZ-2, LZ, LZ High Capacity, EXT-122-EM-K,
VRS-4X*
EZ-2R Series and CV Series
VRS2
Lite2 Series, LT Series exits
VRS3
LX, DK, Sempra and CV3 Series exits
* VRS-4X supplied with a neoprene wall gasket
dimensions (outside)
20” L x 101⁄ 2” H x 7 3⁄ 4” D
211⁄ 4” L x 19 3⁄ 4” H x 6 1⁄ 4” D
15 1⁄ 2” L x 111⁄ 2” H x 4 1⁄ 2” D
81
National Electric Code
NEC (NFPA 70) - 2005
I. General
700.1 Scope. The provisions of this article apply to the electrical safety of the
installation, operation, and maintenance of emergency systems consisting of
circuits and equipment intended to supply, distribute, and control electricity for
illumination, power, or both, to required facilities when the normal electrical
supply or system is interrupted. Emergency systems are those systems legally
required and classed as emergency by municipal, state, federal, or other codes,
or by any governmental agency having jurisdiction. These systems are intended
to automatically supply illumination, power, or both, to designated areas and
equipment in the event of failure of the normal supply or in the event of accident
to elements of a system intended to supply, distribute, and control power and
illumination essential for safety to human life.
FPN No. 1: For further information regarding wiring and installation of
emergency systems in health care facilities, see Article 517.
FPN No. 2: For further information regarding performance and maintenance
of emergency systems in health care facilities, see NFPA 99-2002, Standard for
Health Care Facilities.
FPN No. 3: Emergency systems are generally installed in places of assembly
where artificial illumination is required for safe exiting and for panic control
in buildings subject to occupancy by large numbers of persons, such as
hotels, theaters, sports arenas, health care facilities, and similar institutions.
Emergency systems may also provide power for such functions as ventilation
where essential to maintain life, fire detection and alarm systems, elevators,
fire pumps, public safety communications systems, industrial processes where
current interruption would produce serious life safety or health hazards, and
similar functions.
FPN No. 4: For specification of locations where emergency lighting is considered
essential to life safety, see NFPA 101®-2003, Life Safety Code®.
FPN No. 5: For further information regarding performance of emergency and
standby power systems, see NFPA 110®- 2002, Standard for Emergency and
Standby Power Systems.
700.2 Application of Other Articles. Except as modified by this article, all
applicable articles of this Code shall apply.
700.3 Equipment Approval. All equipment shall be approved for use on
emergency systems.
700.4 Tests and Maintenance.
(A) Conduct or Witness Test. The authority having jurisdiction shall conduct or
witness a test of the complete system upon installation and periodically afterward.
(B) Tested Periodically. Systems shall be tested periodically on a schedule
acceptable to the authority having jurisdiction to ensure the systems are
maintained in proper operating condition.
(C) Battery Systems Maintenance. Where battery systems or unit equipments
are involved, including batteries used for starting, control, or ignition in auxiliary
engines, the authority having jurisdiction shall require periodic maintenance.
(D) Written Record. A written record shall be kept of such tests and maintenance.
(E) Testing Under Load. Means for testing all emergency lighting and power
systems during maximum anticipated load conditions shall be provided.
FPN: For testing and maintenance procedures of emergency power supply
systems (EPSSs), see NFPA 110-2002, Standard for Emergency and Standby Power
Systems.
700.5 Capacity.
(A) Capacity and Rating. An emergency system shall have adequate capacity
and rating for all loads to be operated simultaneously. The emergency system
equipment shall be suitable for the maximum available fault current at its
terminals.
(B) Selective Load Pickup, Load Shedding, and Peak Load Shaving. The
alternate power source shall be permitted to supply emergency, legally required
standby, and optional standby system loads where the source has adequate
capacity or where automatic selective load pickup and load shedding is provided as
needed to ensure adequate power to
(1) the emergency circuits, (2) the legally required standby circuits, and (3) the
optional standby circuits, in that order of priority. The alternate power source shall
be permitted to be used for peak load shaving, provided these conditions are met.
Peak load-shaving operation shall be permitted for satisfying the test requirement
of 700.4(B), provided all other conditions of 700.4 are met. A portable or
temporary alternate source shall be available whenever the emergency generator
is out of service for major maintenance or repair.
700.6 Transfer Equipment.
(A) General. Transfer equipment, including automatic transfer switches, shall be
automatic, identified for emergency use, and approved by the authority having
jurisdiction. Transfer equipment shall be designed and installed to prevent the
inadvertent interconnection of normal and emergency sources of supply in any
operation of the transfer equipment. Transfer equipment and electric power
production systems installed to permit operation in parallel with the normal source
shall meet the requirements of Article 705.
(B) Bypass Isolation Switches. Means shall be permitted to bypass and isolate the
transfer equipment. Where bypass isolation switches are used, inadvertent parallel
operation shall be avoided.
(C) Automatic Transfer Switches. Automatic transfer switches shall be electrically
operated and mechanically held.
(D) Use. Transfer equipment shall supply only emergency loads.
700.7 Signals. Audible and visual signal devices shall be provided, where
practicable, for the purpose described in 700.7(A) through 700.7(D).
(A) Derangement. To indicate derangement of the emergency source.
(B) Carrying Load. To indicate that the battery is carrying load.
(C) Not Functioning. To indicate that the battery charger is not functioning.
(D) Ground Fault. To indicate a ground fault in solidly grounded wye emergency
82
systems of more than 150 volts to ground and circuit-protective devices rated 1000
amperes or more. The sensor for the ground-fault signal dewwwvices shall be
located at, or ahead of, the main system disconnecting means for the emergency
source, and the maximum setting of the signal devices shall be for a ground-fault
current of 1200 amperes. Instructions on the course of action to be taken in event
of indicated ground fault shall be located at or near the sensor location.
FPN: For signals for generator sets, see NFPA 110-2002,Standard for Emergency
and Standby Power Systems.
700.8 Signs.
(A) Emergency Sources. A sign shall be placed at the service entrance
equipment, indicating type and location of on-site emergency power sources.
Exception: A sign shall not be required for individual unit equipment as specified
in 700.12(F).
(B) Grounding. Where the grounded circuit conductor connected to the
emergency source is connected to a grounding electrode conductor at a location
remote from the emergency source, there shall be a sign at the grounding location
that shall identify all emergency and normal sources connected at that location.
II. Circuit Wiring
700.9 Wiring, Emergency System.
(A) Identification. All boxes and enclosures (including transfer switches,
generators, and power panels) for emergency circuits shall be permanently marked
so they will be readily identified as a component of an emergency circuit or system.
(B) Wiring. Wiring of two or more emergency circuits supplied from the same
source shall be permitted in the same raceway, cable, box, or cabinet. Wiring from
an emergency source or emergency source distribution overcurrent protection
to emergency loads shall be kept entirely independent of all other wiring and
equipment, unless otherwise permitted in (1) through (4):
(1) Wiring from the normal power source located in transfer equipment enclosures
(2) Wiring supplied from two sources in exit or emergency luminaires (lighting
fixtures)
(3) Wiring from two sources in a common junction box, attached to exit or
emergency luminaires (lighting fixtures)
(4) Wiring within a common junction box attached to unit equipment, containing
only the branch circuit supplying the unit equipment and the emergency circuit
supplied by the unit equipment
(C) Wiring Design and Location. Emergency wiring circuits shall be designed and
located so as to minimize the hazards that might cause failure due to flooding,
fire, icing, vandalism, and other adverse conditions.
(D) Fire Protection. Emergency systems shall meet the additional requirements
in 700.9(D)(l) and (D)(2) assembly occupancies for not less than 1000 persons or
in buildings above 23 m (75 ft) in height with any of the following occupancy
classes: assembly, educational, residential, detention and correctional, business,
and mercantile.
(1) Feeder-Circuit Wiring. Feeder-circuit wiring shall meet one of the
following conditions:
(1) Be installed in spaces or areas that are fully protected by an approved
automatic fire suppression system
(2) Be a listed electrical circuit protective system with a minimum l-hour fire rating
(3) Be protected by a listed thermal barrier system for electrical system components
(4) Be protected by a fire-rated assembly listed to achieve a minimum fire rating
of 1 hour
(5) Be embedded in not less than 50 mm (2 in.) of concrete
(6) Be a cable listed to maintain circuit integrity for not less than 1 hour when
installed in accordance with the listing requirements
(2) Feeder-Circuit Equipment. Equipment for feeder circuits (including transfer
switches, transformers, and panel boards) shall be located either in spaces fully
protected by approved automatic fire suppression systems (including sprinklers,
carbon dioxide systems) or in spaces with a 1-hour fire resistance rating.
FPN: For the definition of occupancy classification, see Section 6.1 of NFPA 1012003, Life Safety Code.
III. Sources of Power
700.12 General Requirements. Current supply shall be such that, in the event
of failure of the normal supply to, or within, the building or group of buildings
concerned, emergency lighting, emergency power, or both shall be available
within the time required for the application but not to exceed 10 seconds. The
supply system for emergency purposes, in addition to the normal services to
the building and meeting the general requirements of this section, shall be one
or more of the types of systems described in 700.12(A) through 700.12(E). Unit
equipment in accordance with 700.12(F) shall satisfy the applicable requirements
of this article. In selecting an emergency source of power, consideration shall
be given to the occupancy and the type of service to be rendered, whether of
minimum duration, as for evacuation of a theater, or longer duration, as for
supplying emergency power and lighting due to an indefinite period of current
failure from trouble either inside or outside the building. Equipment shall be
designed and located so as to minimize the hazards that might cause complete
failure due to flooding, fires, icing, and vandalism. Equipment for sources of
power as described in 700.12(A) through 700.12(E) where located within assembly
occupancies for greater than 1000 persons or in buildings above 23 m (75 ft) in
height with any of the following occupancy classes — assembly, educational,
residential, detention and correctional, business, and mercantile — shall be
installed either in spaces fully protected by approved automatic fire suppression
systems (sprinklers, carbon dioxide systems, and so forth) or in spaces with a 1-hour
fire rating.
National Electric Code
NEC (NFPA 70) - 2005
FPN No. 1: For the definition of occupancy classification, see Section 6.1 of NFPA
101-2003, Life Safety Code.
FPN No. 2: Assignment of degree of reliability of the recognized emergency
supply system depends on the careful evaluation of the variables at each
particular installation.
(A) Storage Battery. Storage batteries used as a source of power for emergency
systems shall be of suitable rating and capacity to supply and maintain the total
load for a minimum period of 1 1/2 hours, without the voltage applied to the load
falling below 87-1/2 percent of normal. Batteries, whether of the acid or alkali
type, shall be designed and constructed to meet the requirements of emergency
service and shall be compatible with the charger for that particular installation.
For a sealed battery, the container shall not be required to be transparent.
However, for the lead acid battery that requires water additions, transparent or
translucent jars shall be furnished. Automotive-type batteries shall not be used.
An automatic battery charging means shall be provided.
(B) Generator Set.
(1) Prime Mover-Driven. For a generator set driven by a prime mover acceptable
to the authority having jurisdiction and sized in accordance with 700.5, means shall
be provided for automatically starting the prime mover on failure of the normal
service and for automatic transfer and operation of all required electrical circuits.
A time-delay feature permitting a 15-minute setting shall be provided to avoid
retransfer in case of short-time reestablishment of the normal source.
(2) Internal Combustion as Prime Movers. Where internal combustion engines
are used as the prime mover, an on-site fuel supply shall be provided with an onpremise fuel supply sufficient for not less than 2 hours’ full-demand operation of
the system. Where power is needed for the operation of the fuel transfer pumps
to deliver fuel to a generator set day tank, this pump shall be connected to the
emergency power system.
(3) Dual Supplies. Prime movers shall not be solely dependent on a public utility
gas system for their fuel supply or municipal water supply for their cooling systems.
Means shall be provided for automatically transferring from one fuel supply to
another where dual fuel supplies are used.
Exception: Where acceptable to the authority having jurisdiction, the use of
other than on-site fuels shall be permitted where there is a low probability of a
simultaneous failure of both the off-site fuel delivery system and power from the
outside electrical utility company.
(4) Battery Power and Dampers. Where a storage battery is used for control
or signal power or as the means of starting the prime mover, it shall be suitable
for the purpose and shall be equipped with an automatic charging means
independent of the generator set. Where the battery charger is required for the
operation of the generator set, it shall be connected to the emergency system.
Where power is required for the operation of dampers used to ventilate the
generator set, the dampers shall be connected to the emergency system.
(5) Auxiliary Power Supply. Generator sets that require more than 10 seconds
to develop power shall be permitted if an auxiliary power supply energizes the
emergency system until the generator can pick up the load.
(6) Outdoor Generator Sets. Where an outdoor housed generator set is equipped
with a readily accessible disconnecting means located within sight of the building
or structure supplied, an additional disconnecting means shall not be required
where ungrounded conductors serve or pass through the building or structure.
(C) Uninterruptible Power Supplies. Uninterruptible power supplies used to
provide power for emergency systems shall comply with the applicable provisions
of 700.12(A) and 700. 12(B)
(D) Separate Service. Where acceptable to the authority having jurisdiction as
suitable for use as an emergency source of power, an additional service shall be
permitted. This service shall be in accordance with the applicable provisions of
Article 230 and the following additional requirements:
(1) Separate service drop or service lateral
(2) Service conductors sufficiently remote electrically and physically from any other
service conductors to minimize the possibility of simultaneous interruption
of supply
(E) Fuel Cell System. Fuel cell systems used as a source of power for emergency
systems shall be of suitable rating and capacity to supply and maintain the total
load for not less than 2 hours of full-demand operation. Installation of a fuel cell
system shall meet the requirements of Parts II through VIII of Article 692. Where
a single fuel cell system serves as the normal supply for the building or group
of buildings concerned, it shall not serve as the sole source of power for the
emergency standby system.
(F) Unit Equipment. Individual unit equipment for emergency illumination shall
consist of the following:
(1) A rechargeable battery
(2) A battery charging means
(3) Provisions for one or more lamps mounted on the equipment, or shall be
permitted to have terminals for remote lamps, or both
(4) A relaying device arranged to energize the lamps automatically upon failure of
the supply to the unit equipment
The batteries shall be of suitable rating and capacity to supply and maintain at
not less than 87-1/2 percent of the nominal battery voltage for the total lamp load
associated with the unit for a period of at least l l/2 hours, or the unit equipment
shall supply and maintain not less than 60 per cent of the initial emergency
illumination for a period of at least 11/2 hours. Storage batteries, whether of the
acid or alkali type, shall be designed and constructed to meet the requirements of
emergency service. Unit equipment shall be permanently fixed in place (i.e., not
portable) and shall have all wiring to each unit installed in accordance with the
requirements of any of the wiring methods in Chapter 3. Flexible cord-and-plug
connection shall be permitted, provided that the cord does not exceed 900 mm
(3 ft) in length. The branch circuit feeding the unit equipment shall be the same
branch circuit as that serving the normal lighting in the area and connected ahead
of any local switches. The branch circuit that feeds unit equipment shall be clearly
identified at the distribution panel. Emergency luminaires (illumination fixtures)
that obtain power from a unit equipment and are not part of the unit equipment
shall be wired to the unit equipment as required by 700.9 and by one of the wiring
methods of Chapter 3.
Exception: In a separate and uninterrupted area supplied by a minimum of three
normal lighting circuits, a separate branch circuit for unit equipment shall be
permitted if it originates from the same panelboard as that of the normal lighting
circuits and is provided with a lock-on feature.
IV. Emergency System Circuits for Lighting
and Power
700.15 Loads on Emergency Branch Circuits. No appliances and no lamps, other
than those specified as required for emergency use, shall be supplied by emergency
lighting circuits.
700.16 Emergency Illumination. Emergency illumination shall include all required
means of egress lighting, illuminated exit signs, and all other lights specified as
necessary to provide required illumination. Emergency lighting systems shall be
designed and installed so that the failure of any individual lighting element, such
as the burning out of a light bulb, cannot leave in total darkness any space that
requires emergency illumination. Where high-intensity discharge lighting such as
high and low-pressure sodium, mercury vapor, and metal halide is used as the sole
source of normal illumination, the emergency lighting system shall be required to
operate until normal illumination has been restored.
Exception: Alternative means that ensure emergency lighting illumination level is
maintained shall be permitted.
700.17 Circuits for Emergency Lighting. Branch circuits that supply emergency
lighting shall be installed to provide service from a source complying with 700.12
when the normal supply for lighting is interrupted. Such installations shall provide
either of the following:
(l) An emergency lighting supply, independent of the general lighting supply, with
provisions for automatically transferring the emergency lights upon the event of
failure of the general lighting system supply
(2) Two or more separate and complete systems with independent power supply,
each system providing sufficient current for emergency lighting purposes unless
both systems are used for regular lighting purposes and are both kept lighted,
means shall be provided for automatically energizing either system upon failure
of the other. Either or both systems shall be permitted to be a part of the general
lighting system of the protected occupancy if circuits supplying lights for emergency
illumination are installed in accordance with other sections of this article.
700.18 Circuits for Emergency Power. For branch circuits that supply equipment
classed as emergency, there shall be an emergency supply source to which the load
will be transferred automatically upon the failure of the normal supply.
V. Control—Emergency Lighting Circuits
700.20 Switch Requirements. The switch or switches installed in emergency
lighting circuits shall be arranged so that only authorized persons have control of
emergency lighting.
Exception No. 1: Where two or more single-throw switches are connected in parallel
to control a single circuit, at least one of these switches shall be accessible only to
authorized persons.
Exception No. 2: Additional switches that act only to put emergency lights into
operation but not disconnect them shall be permissible.
Switches connected in series or 3- and 4-way switches shall not be used.
700.21 Switch Location. All manual switches for controlling emergency circuits
shall be in locations convenient to authorized persons responsible for their
actuation. In facilities covered by Articles 518 and 520, a switch for controlling
emergency lighting systems shall be located in the lobby or at a place conveniently
accessible thereto. In no case shall a control switch for emergency lighting to be
placed in a motion-picture projection booth or on a stage or platform.
Exception: Where multiple switches are provided, one such switch shall be permitted
in such locations where arranged so that it can only energize the circuit, but cannot
de-energize the circuit.
700.22 Exterior Lights. Those lights on the exterior of a building that are not
required for illumination when there is sufficient daylight shall be permitted to be
controlled by an automatic light-actuated device.
VI. Overcurrent Protection
700.25 Accessibility. The branch-circuit overcurrent devices in emergency circuits
shall be accessible to authorized persons only.
700.26 Ground-Fault Protection of Equipment. The alternate source for
emergency systems shall not be required to have ground-fault protection of
equipment with automatic disconnecting means. Ground-fault indication of the
emergency source shall be provided per 700.7(D).
700.27 Coordination. Emergency system(s) overcurrent devices shall be selectively
coordinated with all supply side overcurrent protective devices.
83
National
Fire
Protection
Assn.
LIFE SAFETY CODE
(NFPA 101) - 2003
Section 4.6 General Requirements
4.6.13 Maintenance and Testing.
4.6.13.1 Whenever or wherever any device, equipment, system, condition,
arrangement, level of protection, or any other feature is required for compliance
with the provisions of this Code, such device, equipment, system, condition,
arrangement, level of protection, or other feature shall thereafter be continuously
maintained in accordance with applicable NFPA requirements or as directed by the
authority having jurisdiction.
4.6.13.2* Existing life safety features obvious to the public, if not required by the
Code, shall be either maintained or removed.
4.6.13.3 Equipment requiring periodic testing or operation to ensure its
maintenance shall be tested or operated as specified elsewhere in this Code or as
directed by the authority having jurisdiction.
4.6.13.4 Maintenance and testing shall be performed under the supervision of a
responsible person who shall ensure that testing and maintenance are made at
specified intervals in accordance with applicable NFPA standards or as directed by
the authority having jurisdiction.
7.8 Illumination of Means of Egress.
7.8.1 General
7.8.1.1* Illumination of means of egress shall be provided in accordance with
Section 7.8 for every building and structure where required in Chapter 11 through
Chapter 42. For the purposes of this requirement, exit access shall include only
designated stairs, aisles, corridors, ramps, escalators, and passageways leading
to an exit. For the purposes of this requirement, exit discharge shall include only
designated stairs, aisles, corridors, ramps, escalators, walkways, and exit passage
ways leading to a public way.
7.8.1.2 Illumination of means of egress shall be continuous during the time that the
conditions of occupancy require that the means of egress be available for use, unless
otherwise provided in 7.8.1.2.2.
7.8.1.2.1 Artificial lighting shall be employed at such locations and for such periods
of time as are necessary to maintain the illumination to the minimum criteria values
herein specified.
7.8.1.2.2 Automatic, motion sensor-type lighting switches shall be permitted within
the means of egress, provided that the switch controllers are equipped for fail-safe
operation, the illumination timers are set for a minimum 15-minute duration, and
the motion sensor is activated by any occupant movement in the area served by the
lighting units.
7.8.1.3* The floors and other walking surfaces within an exit and within the
portions of the exit access and exit discharge designated in 7.8.1.1 shall be
illuminated as follows:
(1) During conditions of stair use, the minimum illumination for new stairs shall be
at least 108 lux (10 ft-candle), measured at the walking surfaces.
(2) The minimum illumination for floors and walking surfaces, other than new
stairs, shall be to values of at least 10.8 lux (1 ft-candle), measured at the floor.
(3) In assembly occupancies, the illumination of the floors of exit access shall be
at least 2.2 lux (0.2 ft-candle) during periods of performances or projections
involving directed light.
(4) * The minimum illumination requirements shall not apply where operations or
processes require low lighting levels.
7.8.1.4* Required illumination shall be arranged so that the failure of any single
lighting unit does not result in an illumination level of less than 2.2 lux (0.2 ftcandle) in any designated area.
7.8.1.5 The equipment or units installed to meet the requirements of Section 7.10
also shall be permitted to serve the function of illumination of means of egress,
provided that all requirements of Section 7.8 for such illumination are met.
7.8.2 Sources of Illumination.
7.8.2.1* Illumination of means of egress shall be from a source considered reliable
by the authority having jurisdiction.
7.8.2.2 Battery-operated electric lights and other types of portable lamps or lanterns
shall not be used for primary illumination of means of egress. Battery-operated
electric lights shall be permitted to be used as an emergency source to the extent
permitted under Section 7.9.
7.9.2 Performance of System.
7.9.2.1* Emergency illumination shall be provided for not less than 1 1/2 hours
in the event of failure of normal lighting. Emergency lighting facilities shall be
arranged to provide initial illumination that is not less than an average of 10.8 lux
(1 ft-candle) and, at any point, not less than 1.1 lux (0.1 ft-candle), measured along
the path of egress at floor level. Illumination levels shall be permitted to decline to
not less than an average of 6.5 lux (0.6 ft candle) and, at any point, not less than
6.5 lux (0.06 ft-candle) at the end of the 1 1/2 hours. A maximum-to-minimum
illumination uniformity ratio of 40 to 1 shall not be exceeded.
7.9.2.2* The emergency lighting system shall be arranged to provide the required
illumination automatically in the event of any interruption of normal lighting due
to any of the following:
(1) Failure of a public utility or other outside electrical power supply
(2) Opening of a circuit breaker or fuse
(3) Manual act(s), including accidental opening of a switch controlling normal
lighting facilities
7.9.2.3 Emergency generators providing power to emergency lighting systems shall
be installed, tested, and maintained in accordance with NFPA 110,
Standard for Emergency and Standby Power Systems. Stored electrical energy
systems, where required in this Code, shall be installed and tested in accordance
with NFPA 111, Standard on Stored Electrical Energy Emergency and Standby
Power Systems.
7.9.2.4* Battery-operated emergency lights shall use only reliable types of
rechargeable batteries provided with suitable facilities for maintaining them in
properly charged condition.
Batteries used in such lights or units shall be approved for their intended use and
shall comply with NFPA 70, National Electrical Code®.
7.9.2.5 The emergency lighting system shall be either continuously in operation or
shall be capable of repeated automatic operation without manual intervention.
7.9.3 Periodic Testing of Emergency Lighting Equipment.
7.9.3.1 Required emergency lighting systems shall be tested in accordance with
one of the three options offered by 7.9.3.1.1, 7.9.3.1.2, or 7.9.3.1.3.
7.9.3.1.1 Testing of required emergency lighting systems | shall be permitted to
be conducted as follows:
(1) Functional testing shall be conducted at 30-day intervals for not less than 30
seconds.
(2) Functional testing shall be conducted annually for not less than 1 1/2 hours if
the emergency lighting system is battery powered.
(3) The emergency lighting equipment shall be fully operational for the duration
of the tests required by 7.9.3.1.1 ( 1 ) and 7.9.3.1.1 (2).
(4) Written records of visual inspections and tests shall be kept by the owner for
inspection by the authority having jurisdiction.
7.9.3.1.2 Testing of required emergency lighting systems shall be permitted to be
conducted as follows:
(1) Self-testing/self-diagnostic battery-operated emergency lighting equipment
shall be provided.
(2) Self-testing/self-diagnostic battery-operated emergency lighting equipment
shall automatically perform not less than once every 30 days a test for not less
than 30 seconds and a diagnostic routine.
(3) Self-testing/self-diagnostic battery-operated emergency lighting equipment
shall indicate failures by a status indicator.
(4) A visual inspection shall be performed at intervals not exceeding 30 days.
(5) Functional testing shall be conducted annually for not less than 1 1/2 hours.
(6) Self-testing/self-diagnostic battery-operated emergency lighting equipment
shall be fully operational for the duration of the 1 1/2 hour test.
(7) Written records of visual inspections and tests shall be kept by the owner for
inspection by the authority having jurisdiction.
7.9.3.1.3 Testing of required emergency lighting systems shall be permitted to be
conducted as follows:
(1) Computer-based, self-testing/self-diagnostic battery-operated emergency
lighting equipment shall be provided.
(2) The emergency lighting equipment shall automatically perform not less than
once every 30 days a test for not less than 30 seconds and a diagnostic routine.
(3) The emergency lighting equipment shall automatically perform annually a test
for not less than 11/2 hours.
(4) The emergency lighting equipment shall be fully operational for the duration
of the tests required by 7.9.3.1.3(2) and 7.9.3.1.3(3).
(5) The computer-based system shall be capable of providing a report of the
history of tests and failures at all times.
7.9 Emergency Lighting.
7.9. 1 General.
7.9.1.1* Emergency lighting facilities for means of egress shall be provided in
accordance with Section 7.9 for the following:
(1) Buildings or structures where required in Chapter 11 through Chapter 42
(2) Underground and limited access structures as addressed in Section 11.7
(3) High-rise buildings as required by other sections of this Code
(4) Doors equipped with delayed-egress locks
(5) Stair shaft and vestibule of smokeproof enclosures, for which the following also
apply:
(a) The stair shaft and vestibule shall be permitted to include a standby
generator that is installed for the smokeproof enclosure mechanical
ventilation equipment.
(b) The standby generator shall be permitted to be used for the stair shaft
and vestibule emergency lighting power supply.
7.9.1.2 For the purposes of 7.9.1.1, exit access shall include only designated stairs,
aisles, corridors, ramps, escalators, and passageways leading to an exit. For the
purposes of 7.9.1.1, exit discharge shall include only designated stairs, ramps, aisles,
walkways, and escalators leading to a public way.
7.9.1.3 Where maintenance of illumination depends on changing from one energy
source to another, a delay of not more than 10 seconds shall be permitted.
84
7.10 Marking of Means of Egress.
7.10.1 General.
7.10.1.1 Where Required. Means of egress shall be marked in accordance with
Section 7.10 where required in Chapter 11 through Chapter 42.
7.10.1.2* Exits. Exits, other than main exterior exit doors that obviously and clearly
are identifiable as exits, shall be marked by an approved sign that is readily visible
from any direction of exit access.
7.10.1.3 Exit Stair Door Tactile Signage. Tactile signage shall be provided to meet
the following criteria, unless otherwise provided in 7.10.1.4:
(1) Tactile signage shall be located at each exit door requiring an exit sign.
(2) Tactile signage shall read as follows: EXIT
(3) Tactile signage shall comply with ICC/ANSI A117.1, American National Standard
for Accessible and Usable Buildings and Facilities.
7.10.1.4 Existing Exemption. The requirements of 7.10.1.3 shall not apply to
existing buildings, provided that the occupancy classification does not change.
7.10.1.5 Exit Access.
7.10.1.5.1 Access to exits shall be marked by approved, readily visible signs
in all cases where the exit or way to reach the exit is not readily apparent to
National Fire Protection
Assn.
LIFE SAFETY CODE
(NFPA 101) - 2003
the occupants.
7.10.1.5.2* New sign placement shall be such that no point in an exit access
corridor is in excess of the rated viewing distance or 30 m (100 ft), whichever is less,
from the nearest sign.
7.10.1.6* Floor Proximity Exit Signs. Where floor proximity exit signs are required
in Chapter 11 through Chapter 42, such signs shall be located near the floor
level in addition to those signs required for doors or corridors. The signs shall be
illuminated in accordance with 7.10.5. Externally illuminated signs shall be sized
in accordance with 7.10.6.1. The bottom of the sign shall be not less than 150 mm
(6 in.) but not more than 455 mm (18 in. ) above the floor. For exit doors, the sign
shall be mounted on the door or adjacent to the door, with the nearest edge of
the sign within 100 mm (4 in.) of the door frame.
7.10.1.7* Floor Proximity Egress Path Marking. Where floor proximity egress path
marking is required in Chapter 11 through Chapter 42, a listed and approved
floor proximity egress path marking system that is internally illuminated shall be
installed within 455 mm (18 in.) of the floor. The system shall provide a visible
delineation of the path of travel along the designated exit access and shall be
essentially continuous, except as interrupted by doorways, hallways, corridors,
or other such architectural features. The system shall operate continuously or at
any time the building fire alarm system is activated. The activation, duration, and
continuity of operation of the system shall be accordance with 7.9.2.
7.10.1.8* Visibility. Every sign required in Section 7.10 shall be located and of such
size, distinctive color, and design that it is readily visible and shall provide contrast
with decorations, interior finish, or other signs. No decorations, furnishings,
or equipment that impairs visibility of a sign shall be permitted. No brightly
illuminated sign (for other than exit purposes), display, or object in or near the line
of vision of the required exit sign that could detract attention from the exit sign
shall be permitted.
7.10.1.9 Mounting Location. The bottom of new egress markings shall be located
at a vertical distance of not more than 2030 mm (80 in.) above the top edge of the
egress opening intended for designation by that marking. Egress markings shall
be located at a horizontal distance of not more than the required width of the
egress opening, as measured from the edge of the egress opening intended for
designation by that marking to the nearest edge of the marking.
7.10.2* Directional Signs. A sign complying with 7.10.3 with a directional
indicator showing the direction of travel shall be placed in every location where
the direction of travel to reach the nearest exit is not apparent.
7.10.3* Sign Legend.
7.10.3.1 Signs required by 7.10.1 and 7.10.2 shall read as follows in plainly legible
letters, or other appropriate wording shall be used:
EXIT
7.10.3.2* Where approved by the authority having jurisdiction, pictograms shall be
permitted.
7.10.4* Power Source. Where emergency lighting facilities are required by the
applicable provisions of Chapter 11 through Chapter 42 for individual occupancies,
the signs, other than approved self luminous signs, shall be illuminated by the
emergency lighting facilities. The level of illumination of the signs shall be in
accordance with 7.10.6.3 or 7.10.7 for the required emergency lighting duration as
specified in 7.9.2.1. However, the level of illumination shall be permitted to decline
to 60 percent at the end of the emergency lighting duration.
7.10.5 Illumination of Signs.
7.10.5.1* General. Every sign required by 7.10.1.2 or 7.10.1.5, other than where
operations or processes require low lighting levels, shall be suitably illuminated by
a reliable light source. Externally and internally illuminated signs shall be legible in
both the normal and emergency lighting mode.
7.10.5.2* Continuous Illumination.
7.10.5.2.1 Every sign required to be illuminated by 7.10.6.3 and 7.10.7 shall be
continuously illuminated as required under the provisions of Section 7.8 unless
otherwise provided in 7.10.5.2.2.
7.10.5.2.2* Illumination for signs shall be permitted to flash on and off upon
activation of the fire alarm system.
7.10.6 Externally Illuminated Signs.
7.10.6.1* Size of Signs.
7.10.6.1.1 Externally illuminated signs required by 7.10.1 and 7.10.2, other than
approved existing signs, unless otherwise provided in 7.10.6.1.2, shall read EXIT, or
other appropriate wording shall be used, in plainly legible letters sized as follows:
(1) For new signs, the letters shall be not less than 150 mm (6 in.) high, with the
principal strokes of letters not less than 19 mm (3/4 in.) wide.
(2) For existing signs, the required wording shall be permitted to be in plainly
legible letters not less than 100 mm (4 in.) high.
(3) The word EXIT shall be in letters of a width not less than 51 mm (2 in.), except
the letter I, and the minimum spacing between letters shall be not less than
9.5 mm ( /8 in. ) .
(4) Sign legend elements larger than the minimum established in 7.10.6.1.1(1)
through 7.10.6.1.1(3) shall use letter widths, strokes, and spacing in proportion
to their height.
7.10.6.1.2 The requirements of 7.10.6.1.1 shall not apply to marking required by
7.10.1.3 and 7.10.1.6.
7.10.6.2* Size and Location of Directional Indicator.
7.10.6.2.1 Directional indicators, unless otherwise provided in 7.10.6.2.2, shall
comply with the following:
(1) The directional indicator shall be located outside of the EXIT legend, not less
than 9.5 mm (3/8 in.) from any letter.
(2) The directional indicator shall be of a chevron type, as shown in Figure
7.10.6.2.1.
(3) The directional indicator shall be identifiable as a directional indicator at a
distance of 12m (40 ft).
(4) A directional indicator larger than the minimum established for compliance with
7.10.6.2.1(3) shall be proportionately increased in height, width and stroke.
(5) The directional indicator shall be located at the end of the sign for the direction
indicated.
FIGURE 7.10.6.2.1 Chevron-Type Indicator.
7.10.6.2.2 The requirements of 7.10.6.2.1 shall not apply to approved existing signs.
7.10.6.3* Level of Illumination. Externally illuminated signs shall be illuminated by
not less than 54 lux (5 ft-candles) at the illuminated surface and shall have a contrast
ratio of not less than 0.5.
7.10.7 Internally Illuminated Signs.
7.10.7.1 Listing. Internally illuminated signs shall be listed in accordance with UL 924,
Standard for Safety Emergency Lighting and Power Equipment, unless they meet one
of the following criteria:
(1) They are approved existing signs.
(2) They are existing signs having the required wording in legible letters not less
than 100mm (4 in.) high.
(3) They are signs that are in accordance with 7.10.1.3 and 7.10.1.6.
7.10.7.2* Photoluminescent Signs.
The face of a photoluminescent sign shall be continually illuminated while the
building is occupied. The illumination levels on the face of the photoluminescent
sign shall be in accordance with its listing. The charging illumination shall be a
reliable light source as determined by the authority having jurisdiction. The charging
light source shall be of a type specified in the product markings.
7.10.8 Special Signs.
7.10.8.1 Sign Illumination.
7.10.8.1.1 Where required by other provisions of this Code, special signs shall be
illuminated.
7.10.8.1.2 Where emergency lighting facilities are required by the applicable
provisions of Chapter 12 through Chapter 42, the required illumination of special
signs shall additionally be provided under emergency lighting conditions.
7.10.8.2 Characters. Special signs, where required by other provisions of this Code,
shall comply with the visual character requirements of ICC/ANSI A117. 1 American
National Standard | for Accessible and Usable Buildings and Facilities.
7.10.8.3* No Exit.
7.10.8.3.1 Any door, passage, or stairway that is neither an exit nor a way of exit
access and that is located or arranged so that it is likely to be mistaken for an exit
shall be identified by a sign that reads as follows:
NO
EXIT
7.10.8.3.2 The NO EXIT sign shall have the word NO in letters 51 mm (2 in.) high,
with a stroke width of 9.5 mm (3/8 in.), and the word EXIT in letters 25 mm (1 in.)
high, with the word EXIT below the word NO, unless such sign is an approved
existing sign.
7.10.8.4 Elevator Signs. Elevators that are a part of a means of egress (see 7.2.13.1)
shall have signs with a minimum letter height of 16 mm (5/8 in.) posted in every
elevator lobby as follows:
(1) *Signs that indicate that the elevator can be used for egress, including any
restrictions on use
(2) *Signs that indicate the operational status of elevators
7.10.9 Testing and Maintenance.
7.10.9.1 Inspection. Exit signs shall be visually inspected for operation of the
illumination sources at intervals not to exceed 30 days, or shall be periodically
monitored in accordance with 7.9.3.1.3.
7.10.9.2 Testing.
Exit signs connected to or provided with a battery-operated emergency illumination
source, where required in 7.10.4, shall be tested and maintained in accordance with
7.9.3.
85
Limited Warranty
Product
Unit
Warranty
(Years)
Battery Warranty
Full
(Years)
Pro-Rata
(Years)
Liteforms Emergency Lighting Units
LiteScape Series
with Spectron option
nicad battery models
nicad with Spectron option
EZ-2 Series
with Spectron option
LZ Series
with Spectron option
LZ High Capacity Series
with Spectron option
nicad battery models
nicad with Spectron option
LM Series
lead-calcium battery models
lead-calc. with Spectron option
nicad battery models
nicad with Spectron option
EZ-2R Series
with Spectron option
T-Grid Series
with Spectron option
EXT-122-EM Series
Lite2 Series
with Spectron option
Delite Series
N4X Series
with Spectron option
AS Series
with Spectron option
wet lead-acid battery models
wet lead-acid with Spectron option
wet nicad battery models
wet nicad with Spectron option
IPS Series
XPB Series
UFO-3AW, UFO-4W models
UFO-5W, UFO-12W models
UFO-5AW models
UFO-6W, UFO-6WI,
UFO-6W-CLD, UFO-7W,
UFO-7WI, UFO-LP
and UFO-MH models
LX LED exit
AC-Only models
Emergency models
Emergency Spectron models
DK incandescent exit
AC-Only models
Emergency models
LT combo exit
Spectron models
NYXC combo exit
SMC combo exit
Sempra cast LED exit*
AC-Only models
Emergency models
Emergency Spectron models
NYDC cast LED exit
AC-Only models
Emergency models
LN4X wet location LED exit
AC-Only models
Emergency models
Emergency Spectron models
Freedom LED aluminum exit
AC-Only models
Emergency models
LEDS aluminum LED exit
AC-Only models
Emergency models
1
5
1
5
3
5
1
5
1
5
3
5
1
2
1
2
3
5
1
5
1
2
1
2
5
4
9
4
3
5
5
5
5
4
9
8
1
5
3
5
3
5
3
5
1
3
5
1
3
5
1
5
1
5
1
5
3
3
1
2
3
5
“
“
“
1
2
1
2
3
5
3
5
1
3
5
1
3
5
1
2
1
2
1
2
3
3
1
2
3
5
“
“
“
5
4
9
8
3
5
3
5
5
3
5
5
3
5
5
4
9
8
14
13
3
3
–
–
–
–
–
–
–
5
5
5
–
1
2
–
9
8
3
5
5
5
5
5
–
1
1
2
1
1
–
9
5
4
5
5
Liteforms Exit Signs
5
–
–
5
1
9
5 Lifetime
5
5
–
1
–
9
5
5
5
–
1
2
–
9
8
5
5
–
1
–
4
5
5
–
1
–
9
* Includes Sempra, Sempra SC, SC-WL, MR and SERS Series exit signs.
86
Unit
Warranty
Product
(Years)
Battery Warranty
Full
(Years)
Pro-Rata
(Years)
5
5
–
1
–
9
5
5
–
1
–
9
5
5
5
–
1
2
–
9
8
5
–
–
5
5
–
1
–
9
5
5
–
1
–
9
3
3
–
1
–
5
Liteforms Exit Signs
NYX LED exit
AC-Only models
Emergency models
CMX exit
AC-Only models
Emergency models
LE edge-lit LED exit
AC-Only models
Emergency models
Emergency Spectron models
LES edge-lit LED exit
AC-Only models
NYE edge-lit LED exit
AC-Only models
Emergency models
NYES edge-lit LED exit
AC-Only models
Emergency models
DEX special wording exit
AC-Only models
Emergency models
SlimLite Series
CV Series
CVEC Series
CV3 LED exit
AC-Only models
Emergency models
CVT Tandem LED exit
CVD cast LED exit
AC-Only models
Emergency models
CVER edge-lit LED exit
AC-Only models
Emergency models
Clearview Life Safety Products
1
1
1
1
1
1
5
5
5
5
5
5
–
1
1
–
9
9
5
5
–
1
–
9
5
5
–
1
–
9
Consult factory for warranties available with AC Inverter Systems.
Emergency Lighting Units and Batteries
Dual-Lite warrants to the purchaser that its products have been carefully manufactured and
inspected, and are warranted to be free from defect of workmanship and materials when used
as intended. See chart at left for duration of warranties for units and batteries (fuses and lamps
are excluded from all warranties).
Batteries must be placed in service or recharged within nine (9) months from invoice date or
ninety (90) days from recommended recharge date stamped on carton, whichever is longer
(NiCad batteries excluded).
The warranties are subject to proper installation and maintenance in accordance with the
instructions supplied. Any abuse or misuse contrary to normal operation shall void this
warranty.
This warranty does not cover damages caused by installation in areas with other than normal
temperatures and environmental conditions per application specifications. Dual-Lite assumes
no responsibility for any damage to people, property, apparatus or otherwise resulting from
improper installation or maintenance of its emergency lighting units.
Warranty coverage shall not apply to any equipment of another manufacturer used in conjunction
with Dual-Lite systems.
Warranty does not cover damages caused by abuse, fire or acts of God.
To obtain prior written approval to return defective items, please contact your local manufacturer’s
representative. After prior written notification has been given and approval obtained for the
return, merchandise may be returned, freight prepaid, to Dual-Lite.
Customer is responsible for secure packaging of returned materials to provide best possible
assurance against breakage in shipment.
If, upon inspection, the merchandise is found to be defective replacement or repair shall be
made. Dual-Lite’s sole obligation under this limited warranty is to repair or replace the defective
parts or products, at its discretion, providing such defective parts or products are brought to
its attention within the specified warranty time period, and does not include any other costs
such as removal of defective parts or product, installation, labor or consequential damages of
any kind, the exclusive remedy being to require such new parts or products to be furnished. All
other warranties, expressed or implied, including warranties of merchantability or warranties
of fitness for any particular purpose we hereby disclaim.
Dual-Lite Distributors and Representatives have no authority to change this warranty without
written permission from Dual-Lite.
Dual-Lite reserves the right to determine the best method of correcting warranty problems.
All specifications subject to change without notice.
Some states do not allow the exclusion of limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you. This warranty gives you specific legal
rights, and you may also have other rights which vary from state to state.
Synchron Series Single-Phase Inverters ............................................. 88 to 91
Spectron LSN Series Single-Phase Inverters .................................... 92 to 101
Trident Series Three-Phase Inverters .................................................... 103 to 106
Auxiliary Transfer Switching Device ................................................................... 107
87
Single Phase Systems
88
Single Phase Systems
89
Single Phase Systems
90
Single Phase Systems
91
Single Phase Systems
92
Single Phase Systems
93
Single Phase Systems
94
Single Phase Systems
95
Single Phase Systems
96
Single Phase Systems
97
Single Phase Systems
98
Single Phase Systems
Note: Batteries for all Spectron LSN inverter
systems are shipped separately.
Batteries must be installed and energized within six
months of shipment or warranty is void.
99
Single Phase Systems
100
Single Phase Systems
101
Three Phase Systems
102
TRX Three Phase Systems
3-Phase
rident
Inverter Power Systems
GENERAL SPECIFICATIONS
INPUT
Voltage:
120/208VAC, 60Hz 3-phase, 4-wire
plus ground
Voltage Range: +10%, -20%
Frequency Range: 47-63Hz.
User Interface Panel
Current Distortion:
4% maximum reflected THD at
full load
Current Limit:
125% of full load input current
Walk-ln: 20 seconds to full load
Power Factor:
0.99 lagging minimum at full load
Surge Protection:
Sustains input surges without damage,
per criteria listed in IEC 1000-4-5
ENVIRONMENTAL
Operating Temperature:
UPS: 32°F to 104°F (0°C to 40°C)
Battery: 68°F to 86°F (20°C to 30°C)
Relative Humidity:
0-95% non-condensing
TRX Series
10 to 30 kVA, 3-Phase UPS
Flexibility In Application
The Dual-Lite Trident TRX Series’
quiet operation, small footprint
and lightweight design is perfect
for installation in computer rooms,
yet the Trident TRX Series is
rugged enough for factory floors
or maintenance rooms. Precisely
controlled system output is suitable
for any lighting or critical life safety
loads up to the full rated output
capacity.
Outstanding Features
• Unmatched reliability
• Smallest system footprint
• Excellent efficiency with nonlinear
and partial loads
• Outstanding dynamic response
• All-digital ActiveStar controls and
graphical user interface
• Power factor corrected
• Harmonic current cancellation
Operating Altitude:
Up to 3,300 ft. (1,000m)
without derating
Acoustical Noise:
Less than 54 dBA typical, measured 3.3
ft. (1 m) from the unit
OUTPUT
Voltage:
120/208VAC, 60Hz., 3-phase, 4-wire
plus ground
Voltage Adjustment Range: ±5%
Voltage Regulation:
1% for balanced load
2% for 100% unbalanced load
Dynamic Regulation:
±4% deviation for 100% load step
±1% for loss or return of AC input
Transient Response Time:
Recover to ±1% of steady state within
1 cycle
Voltage Distortion:
For linear loads, 1% THD. Less than
4% THD for 100% nonlinear loads
without kVA/kW derating
Phasing Balance:
120° ±0.5° for balanced load
120° ±1° for 100% unbalanced load
Frequency Regulation: ±0.1%
Load Power Factor Range:
0.70 lagging to 0.95 leading without
derating
Overload:
125% of full load for 10 minutes
150% for one minute, with true
sinusoidal waveform
Outstanding Support
Assistance is available from the
largest Customer service and Support
network in the country.
Standards
Complies with UL 1778 (UPS) and UL
924 (Emergency) standards, and is
CSA certified.
103
TRX Three Phase Systems
Product Selector
Size kVA/kW
UPS Cabinet No.
Battery Cabinet No. (1)
10/8
TRXSAA10114
TRXBATAR141BNR
15/12
TRXSAB10114
TRXBATBR271BNR
20/16
TRXSAC10114
TRXBATCR371BNR
30/24
TRXSAD10114
TRXBATDR311BNR(2)
(1) 90 minute run time. Contact factory for other run times.
(2) Two battery cabinets required on 30 kVA models
Options
480 VAC Operation (Contact factory for proper configuration)
Intellislot Relay Board
Seismic Floor Kit
Site Planning Data
Trident UPS - 90 Minute Operation
Battery
System
AC
AC Input
(1)
Rating
Voltage
Current
Nom. Battery
Max.
kVA kW Input Output Nom. Max. OCPD VDC kW
Discharge
10-30 kVA, 3-Phase, 60 Hz.
AC Output
Mechanical Data
Current No. Of Dimensions - WxDxH Weight
Heat Dis
Nom. OCPD Cabinets
inches (mm)
Ibs. (kg)
BTU/hr (kWH)
10 8
208 208
28
35
50
288
9
37A
28 50
2
51x32.5x63 (1,295x826x1,600) 2,800 (1,275)
2,800 (0.82)
15 12
208 208
42
53
60
288
13
55A
42 60
2
51x32.5x63 (1,295x826x1,600) 3,350 (1,526)
4,200 (1.23)
20 16
208 208
56
70
80
288
18
73A
56 80
2
83x32.5x63 (2,057x826x1,600) 4,150 (1,890)
5,500 (1.61)
30 24
208 208
83 104
125
288
26
110A
83 125
3
142x32.5x63 (1,981x826x1,600) 6,650 (3,028)
8,300 (2.43)
-- 1,3,7
--
--
--
1,3,7
See Notes For Table (Below):
1,3,7
6
--
--
--
--
(1) Contact factory for 480 VAC applications.
Cabinet Configurations
10 and 15 kVA Models
20 kVA Models
30 kVA Models
NOTES FOR TABLE:
1. UPS input and bypass cables must be run in separate conduit from output cables
2. Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized ground conductors are recommended. Neutral conductors to be sized for full capacity per
NEC 310-15 (b)(4). References are per NEC 1999.
3. Wiring requirements:
AC Input: 3-phase, 4-wire, plus ground
AC Output: 3-phase, 3- or 4-wire, plus ground
4. All wiring is to be in accordance with national and local electric codes.
5. Minimum access clearance is 3 ft. (0.9m) front and 18 in. (457mm) above the UPS.
6. Top or bottom cable entry through removable access plates. Punch plate to suit conduit size, then replace.
7. Control wiring and power wiring must be run in separate conduit.
ADDITIONAL NOTES:
• If site configuration includes a backup emergency generator, it is recommended that the engine generator set be properly sized and equipped for a UPS application.
Generator options would typically include an isochronous governor (generator frequency regulation) and a UPS-compatible regulator (generator voltage regulation).
Consult generator manufacturer for required generator options and sizing.
• If site configuration includes an automatic transfer switch, refer to Power Line titled “Criteria for Application of Automatic Transfer Switches (ATS) With Uninterruptible
Power Supply (UPS) Systems,” publication 91K-PLT-48-02. It is also recommended that the transfer switch be equipped with auxiliary contacts for UPS “on generator”
current limit. Consult transfer switch manufacturer for required transfer switch options and sizing.
• If site configuration requires an external isolated maintenance bypass circuit, it should be noted that utility AC input might not be in phase with the UPS AC output.
Consult a Dual-Lite sales representative or applications engineer.
104
TRN Three Phase Systems
3-Phase
rident
Inverter Power Systems
GENERAL SPECIFICATIONS
INPUT
Voltage: 208 or 480 VAC, 60 Hz (3-phase,
3-or 4-wire plus ground)
Voltage Range: +10, -15% (no battery
discharge at-20%)
Frequency Range: 60 Hz, ± 5
Current Distortion: 10% maximum
reflected THD at full load with optional
input filter. 30% THD without filter
Current Limit: 115% of full load
input current
Current Walk-in: 20 seconds to full load
Power Factor: 0.80 lagging minimum at
full load. Up to 0.96 lagging at full load
with optional input filter
Surge Protection: Sustains input surges
without damage, per criteria
listed in ANSI C62.41-1980 (IEEE 587)
TRN Series
30 to 130 kVA, 3-Phase UPS
• Unmatched heritage of
reliability and availability
• Smallest system footprint
• Excellent efficiency with
nonlinear loads and partial loads
• Outstanding dynamic response
• All-digital controls and graphical
user interface
Dual-Lite has reinvented the dualconversion UPS. The TridentTM Series is
the result of an international design
collaboration and more than a decade of
advanced research.
Every aspect of the TridentTM Series shows
careful design and attention to detail.
The rugged power train and advanced
DSP controls were subjected to computer
simulations and thermal analysis to
ensure reliable performance in every
environment.
Even the physical packaging is uniquely
efficient, to make fully configured systems
more compact than our competitors.
Best of all, it’s a Dual-Lite product designed to deliver an impressive millionhour critical bus MTBF.
Voltage Distortion: For linear loads,
1% THD. Less than 2.5% THD for 100%
nonlinear loads without kVA/kW derating
Phasing Balance: 120° ±0.5° for balanced
load. 120° ±1° for 100% unbalanced load
Frequency Regulation: ±0.1%
Load Power Factor Range: 1.0 to 0.7
lagging without derating
Overload: 125% of full load for ten
minutes. 150% for one minute, with true
sinusoidal waveform
STANDARDS
Complies with UL 1778 (UPS) and UL 924
(Emergency) standards, and is CSA certified.
ENVIRONMENTAL
Operating Temperature: 0° to 40°C (UPS),
20° to 30°C (battery)
Non-Operating Temperature: -20°C
to 70°C
Relative Humidity: 0-95% non-condensing
Operating Altitude: Up to 6,600 feet
(2000 meters) without derating
Acoustical Noise: Less than 65 dBA 1
meter from unit (typical)
OUTPUT
Voltage: 208 or 480 VAC (3-phase, 4-wire
plus ground)
Voltage Adjustment Range: ±5%
Voltage Regulation:
±0.5% for balanced load
±1.0% for 100% unbalanced load
Dynamic Regulation: ±2.5% deviation for
100% load step.
±1% for loss or return of AC input
Transient Response: Recover to ±1% of
steady state within 1 cycle
Slim-Line Distribution Cabinet
kVA
All
Dimensions (In.)
(WxDxH)
10 x 32.5 x 71
Weight
(Ib)
250
Maintenance Bypass Cabinets
Model
L
N
P
Q
Dimensions (In.)
(WxDxH)
25 x 32.5 x 71
25 x 32.5 x 71
31.7 x 32.5 x 71
31.7 x 32.5 x 71
Weight (Ib)
15-50 kVA
660
660
1,210
1,210
Weight (Ib)
65-80 kVA
750
750
1,320
1,320
Weight (Ib)
100-130 kVA
800
800
1,540
1,540
105
TRN Three Phase Systems
Product Selector
Size kVA/kW
30/24
40/32
50/40
65/52
80/64
100/80
130/104
UPS Cabinet No. (480/480)
TRNSAD2026B
TRNSAE2026B
TRNSAF2026B
TRNSAG2026B
TRNSAH2026B
TRNSAI2026B
TRNSAJ2026B
UPS Cabinet No. (208/208)
TRNSAD1016B
TRNSAE1016B
TRNSAF1016B
TRNSAG1016B
TRNSAH1016B
TRNSAI1016B
TRNSAJ1016B
Battery Pack No.*
TRNBATDX471BNL
TRNBATEX312BNL
TRNBATFX372BNL
TRNBATGX472BNL
TRNBATHX274BNL
TRNBATIX473BNL
TRNBATJX474BNL
* 90 minute run time. Contact factory for other run times.
Options
Programmable Relay Board
Internal Modem
Network Interface Card
AS/400 Signal Cable
Remote Alarm Status Panel
Cabinet Configurations
30 kVA Models
40 - 50 kVA Models
65 kVA Models
Site Planning Data
80 kVA Models
Trident UPS - 90 Minute Operation
Battery
System AC
AC Input
Rating
Voltage
Current
Nom. Battery
Max.
kVA kW Input Output Nom. Max. OCPD VDC kW
Discharge
30 24 208 208
80 92
150 480
26
66A
30-130 kVA, 3-Phase, 60 Hz.
AC Output
Mechanical Data
Current No. Of Dimensions - WxDxH Weight Heat Dis
Nom. OCPD Cabinets
inches (mm)
Ibs. (kg)
BTU/hr (kWH)
83 125
2
80.7x32.5x71 (2,050x826x1,803) 7,250 (3,303) 8,500 (2.49)
30 24
480 208
33
38
60
480
26
66A
83 125
2
80.7x32.5x71 (2,050x826x1,803) 7,150 (3,257)
30 24
480 480
33
38
60
480
26
66A
36 50
2
80.7x32.5x71 (2,050x826x1,803) 6,950 (3,166) 11,000 (3.22)
7,500 (2.19)
40 32
208 208
106 122
175
480
34
88A
111 150
3
130x32.5x71 (3,294x826x1,803) 9,600 (4,373) 11,000 (3.22)
40 32
480 208
44
51
80
480
34
88A
111 150
3
130x32.5x71 (3,294x826x1,803) 9,500 (4,328) 10,000 (2.93)
40 32
480 480
44
51
80
480
34
88A
48 60
3
130x32.5x71 (3,294x826x1,803) 9,300 (4,237) 10,000 (2.93)
50 40
208 208
133 153
225
480
43
109A
139 175
3
130x32.5x71 (3,294x826x1,803) 10,200 (4647) 14,000 (4.10)
50 40
480 208
55
63
90
480
43
109A
139 175
3
130x32.5x71 (3,294x826x1,803) 10,100 (4601) 12,000 (3.51)
50 40
480 480
55
63
90
480
43
109A
60 80
3
65 52
208 208
171 196
300
480
55
141A
180 25
3
137.4x32.5x71 (3,490x826x1,803) 12,800 (5831) 18,000 (5.27)
65 52
480 208
70
81
125
480
55
141A
180 225
3
137.4x32.5x71 (3,490x826x1,803) 12,600 (5740) 15,000 (4.39)
65 52
480 480
70
81
125
480
55
141A
78 100
3
137.4x32.5x71 (3,490x826x1,803) 12,400 (5649) 15,000 (4.39)
80 64
208 208
210 241
350
480
68
174A
222 300
5
139.4x32.5x71 (3,541x826x1,803) 14,700 (6697) 22,000 (6.44)
80 64
480 208
87 100
150
480
68
174A
222 300
5
139.4x32.5x71 (3,541x826x1,803) 14,500 (6606) 18,000 (5.27)
80 64
480 480
87 100
150
480
68
174A
96 125
5
139.4x32.5x71 (3,541x826x1,803) 14,300 (6515) 18,000 (5.27)
100 80
208 208
261 300
500
480
85
218A
278 350
4
196.2x32.5x71 (3,713x826x1,803) 18,950 (8633) 26,000 (7.61)
100 80
480 208
108 124
200
480
85
218A
278 350
4
196.2x32.5x71 (3,713x826x1,803) 18,750 (8542) 21,000 (6.14)
100 80
130x32.5x71 (3,294x826x1,803) 9,900 (4510)
12,000 (3.51)
480 480
108 124
200
480
85
218A
120 150
4
196.2x32.5x71 (3,713x826x1,803) 18,550 (8451) 21,000 (6.14)
130 104 208 208
339 390
600
480
111
283A
361 450
5
245.2x32.5x71 (6,228x826x1,803) 24,000 (10934) 33,000 (9.66)
130 104 480 208
140 161
250
480
111
283A
361 450
5
245.2x32.5x71 (6,228x826x1,803) 23,800 (10843) 27,000 (7.90)
130 104 480 480
140 161
250
480
111
283A
156 200
5
245.2x32.5x71 (6,228x826x1,803) 23,600 (10751) 27,000 (7.90)
--
--
--
1,3,7
1,3,7
--
See Notes For Table (Below):
-- 1,3,7
NOTES FOR TABLE:
1. The unit’s input and bypass cables must be run in separate conduit from
output cables.
2. Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized
ground conductors are recommended. Neutral conductors to be sized for full
capacity per NEC 310-15(b)(4). References are per NEC 1999.
3. Wiring requirements:
AC Input:
3-phase, 3-wire plus ground or 3-phase, 4-wire plus ground
AC Output:
3-phase, 4-wire plus ground
DC Input:
2-wire (positive and negative), plus ground
4. All wiring is to be in accordance with national and local electrical codes.
5. Minimum access clearance is 3 feet front and 1 foot above the unit.
6. Top or bottom cable entry through removable access plates. Cut plate to suit
conduit size then replace.
7. Control wiring and power wiring must be run in separate conduit.
8. Weights and dimensions shown include battery cabinets.
9. OCPD-Overcurrent Protection Device.
106
130 kVA Models
100 kVA Models
--
8
8
--
ADDITIONAL NOTES:
• If site configuration includes a back-up emergency generator, it is recommended
that the engine generator set be properly sized and equipped for the unit’s
application. Generator options would typically include an isochronous governor
(generator frequency regulation) and a UPS-compatible regulator (generator
voltage regulation). Consult generator manufacturer for required generator
options and sizing.
• If site configuration includes an automatic transfer switch, refer to the Power
Line titled “Criteria for Application of Automatic Transfer Switches (ATS) with
Uninterruptible Power Supply (UPS) Systems” publication 91K-PLT-48-02. It is also
recommended that the transfer switch be equipped with auxiliary contacts for
the unit’s “on generator“ current limit. Consult transfer switch manufacturer for
required transfer switch options and sizing.
• If site configuration requires an external isolated maintenance bypass circuit,
it should be noted that utility AC input may not be in phase with the unit’s AC
output. Consult local sales representative or applications engineer.
ATSD
Auxiliary Transfer Switching Device
Features
• Device allows generator or inverter
supplied egress lighting fixtures to
be switched
• For factory or field installation
• Compatible with all
fluorescent fixtures
• Easy installation inside of
ballast channel
• For use with switched fluorescent
lighting fixtures
•
•
•
•
Battery case made of
galvanized steel
Universal 120/277VAC operation
Low power consumption
Temperature range: 0°C to 50°C
(32°F to 122°F)
• UL Listed
Ordering Information
ATSD
Installation
The ATSD auxiliary transfer device does not affect normal fixture operation and comes fully assembled to mount in the fixture
ballast channel. In addition to available wiring, the device requires a direct, unswitched connection to a generator- or invertersupplied emergency panel and an unswitched source on the same branch circuit as the switched supply (see diagram below).
Application
Dimensions
8.0”
20.4cm
1.18”
3.0cm
1.18”
3.0cm
The ATSD auxiliary transfer switching device
works in conjunction with an auxiliary generator
or inverter power system to power existing
fluorescent fixtures for egress lighting regardless
of fixture wall switch position. The device consists
of relay switching circuitry and fusing in one
compact galvanized steel case. One auxiliary
transfer switch device per fixture can be used to
bypass fixture wall switch allowing the building’s
generator to bring on switchable fixtures and not
just those on “night-light” circuits. The auxiliary
transfer switch device is suitable for use in indoordry or damp location fixtures. Recommended
applications include: auditoriums, classrooms, or
any other location with generator- or invertersupplied emergency lighting.
107
Notes
108
Notes
109
Notes
110
Dual-Lite • A Hubbell Lighting, Inc. Life Safety Products Brand • www.dual-lite.com
Copyright© Hubbell Lighting, Inc., All Rights Reserved • Specifications subject to change without notice. • Printed in U.S.A.
0603254
3/06
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23 Instance ID : uuid:431f8474-c5b6-4aff-9ce1-d1a4a38b0921 Document ID : adobe:docid:indd:d4117685-aeb2-11da-8710-e2d54255d799 Rendition Class : proof:pdf Derived From Instance ID : d4117684-aeb2-11da-8710-e2d54255d799 Derived From Document ID : adobe:docid:indd:c20d943a-ae8b-11da-8710-e2d54255d799 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches Manifest Reference Document ID : adobe:docid:photoshop:fad6cb1b-0412-11da-ac88-afb10cd33dca, adobe:docid:photoshop:5adc27cf-149c-11da-bef5-fe11c0148134, adobe:docid:photoshop:0dc90bbc-0c4e-11d8-900f-cb75de43c9a9, adobe:docid:photoshop:ffebb212-3b6b-11d8-8729-8425211b5967 Create Date : 2007:06:19 17:00:38-04:00 Modify Date : 2007:06:19 18:06:52-04:00 Metadata Date : 2007:06:19 18:06:52-04:00 Creator Tool : Adobe InDesign CS2 (4.0.5) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 7675 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 7.0 Trapped : False Has XFA : No Page Count : 112 Creator : Adobe InDesign CS2 (4.0.5)EXIF Metadata provided by EXIF.tools