56178 Catalog
10205-Catalog 10205-Catalog 10205-Catalog 782520 Batch5 unilog cesco-content
56178-Catalog 56178-Catalog 56178-Catalog 782520 Batch12 unilog cesco-content
2014-11-11
: Pdf 56178-Catalog 56178-Catalog Batch12 unilog
Open the PDF directly: View PDF .
Page Count: 112
Download | |
Open PDF In Browser | View PDF |
To be an innovator, first you have to listen to what your customers say. I nnovation doesn’t happen by chance. Yes, it takes experience... dedication to quality... and a willingness to think “outside the box.” But if you’re going to continually set industry standards, that thinking had better reflect what your customers expect. Which is why at Dual-Lite, innovation begins with listening carefully to our customers. About Our Products All our latest products began with nationwide customer interviews to find out what you want and need...and what you think. We then took this product-shaping feedback, factored in our own high standards for quality, and developed products by which others are now measured. As you review our product offerings, you’ll see that this strong tradition of excellence continues today with exit signs and emergency lighting that include the latest advances and the highest level of performance. About Our Quality Quality is the key reason why Dual-Lite remains the industry’s most asked-for brand. You’ll see it in our construction, components, design and engineering, all of which combine to deliver the highest level of customer satisfaction, and the industry’s best safety record. Number One Brand It’s our unique “listen-to-learn” business philosophy that’s made Dual-Lite the industry’s Number One brand ...and why our name still remains synonymous with life safety excellence after more than 65 years. 2 A Tradition Of Excellence Sleek lines... low-profile silhouette... innovative design... Only one line of life safety equipment fits this description —the Liteforms® Collection by Dual-Lite. Our unique styling is backed up by the substance of high-quality, high-performance components and sturdy construction features that helps ensure long-life, worryfree operation and lower maintenance expense. Plus, with our extensive product offering, you’ll find a Liteforms exit sign or emergency lighting unit for nearly every commercial, industrial or institutional application. That’s the LiteForms tradition of excellence LiteForms, delivering the perfect solutions to all your life safety product needs. Collection Focused On Value For many, value equates to cost-effective products that perform reliably. For others, value means lowering transaction costs and minimizing returns. For everyone, value is simply having your expectations met or exceeded every time. Everything about Dual-Lite’s Clearview Collection is focused on delivering the type of value and high output performance that our customers have come to expect. Additionally, Clearview Collection products share a “family” style that results in a unified designer look when they are installed together. With Clearview products, you can create life safety lighting systems with eye appeal. Value... Performance... Style... That’s the Clearview difference. Protection From Severe Conditions Whether your need is a vandalresistant exit sign, explosion-proof emergency lighting, or units that can withstand damp, exposed or hazardous conditions, the solution is the Ultrex line, from Dual-Lite. Ultrex features products for almost every severe condition you’ll encounter. Each Ultrex unit is designed to provide unsurpassed, worry-free performance and lower maintenance — also lowering costs. Ultrex Choices Dual-Lite offers a broad choice of products for severe condition applications, including: Emergency Lighting Units • EZ-2 Damp Series • LZ Damp Series • LM Damp Series • N4X Series • IPS Series • XPB Series • Lampak Series Exit Signs LX Series • LT Series • LN4X Series • Sempra SC Series • Sempra SC WL Series • Freedom LED Series • LEDS Series • Remote Lighting Heads GNX Series • OMS Series • Features • Meets UL 924 standards for self-testing/self diagnostic models. Self-Testing/Self-Diagnostic Electronics System • Provides automatic self-diagnostic monitoring and testing of unit operation. • Automatically performs routine maintenance and assures operational readiness at all times. • Monitors charger and lamp operation. • Routine discharge cycles insure optimum battery performance and maximum useful life. • Automatic self-test every 28 days and extended operation self-test every 6 months. • Automatic low voltage disconnect. • Automatic unit transfer in brownout conditions. • Automatic 15-minute retransfer delay (units). Technologically advanced self-testing, self-diagnostic electronics provide increased reliability and decreased maintenance. All Dual-Lite models ordered with the Spectron option provide: • Visual indication of AC power status • Visual Indication of all self-diagnostic test cycles • Visual indication of unit malfunctions including: • Battery disconnected • Battery fault • Charger fault • Transfer fault • Lamp fault • Automatic AC lockout circuit. • Flashing LED indication of unit malfunction. • All detected malfunctions retained in memory until corrected and retested. • Test switch allows a system check at any time. • Supports exit sign flashing options Test Intervals The Spectron self-testing/self-diagnostic system conducts tests to verify proper operation continuously and on monthly, and semiannual intervals. Manual tests may also be performed at any time. A malfunction during any self test will be indicated by the external status indicators . Emergency Lighting Units LiteForms Emergency Lighting Units LiteScape Series EZ-2 Series LZ Series LZ (HC) Series LM Series EZ-2R Series T-Grid Series EXT Series Lite2 Series Delite Series N4X Series AS Series IPS Series XPB Series Lampak Series Exit Signs Emergency Lighting Emergency Lighting Guaranteed Code Compliant Emergency Lights.................................................. 14, 15 Commercial Emergency Lights..................................................................................16 Designer Emergency Lights.................................................................................................. 17 High Capacity Designer Emergency Lights.......................................................... 18, 19 High Capacity Emergency Lights........................................................................ 20, 21 Recessed Emergency Lights.................................................................................................. 22 Recessed T-Grid Emergency Lights. ...........................................................................23 Recessed Gimbal Emergency Light............................................................................24 Emergency Lighting Square Units.................................................................... 25 Emergency Lighting Cylinder Units...........................................................................26 Harsh Environment Emergency Lights.......................................................................27 Industrial Emergency Lights.............................................................................. 28, 29 Wet Location Emergency Lights. ....................................................................... 30, 31 Explosion-Proof Emergency Lights..................................................................... 32, 33 Fluorescent Power Packs. .....................................................................34 to 38 LiteForms Exit Signs LX Series DK Series LT Series NYXC Series SMC Series Sempra Series Sempra MR Series Sempra SC Series Sempra SCWL Series Sempra SERS Series NYDC Series LN4X Series Freedom LED Series LEDS Series NYX Series CMX Series LE Series LES Series NYE Series NYES Series DEX Series Designer LED Exit Signs........................................................................................................ 40 AC Incandescent Exit Signs................................................................................................... 41 Designer Tandem Units..................................................................................... 42, 43 New York Tandem Units. .........................................................................................44 Tandem Units with Side Mounted Heads...................................................................45 Diecast LED Exit Signs.................................................................................................... 46, 47 Master/Remote Diecast LED Exit Signs......................................................................... 48, 49 Severe Conditions Diecast LED Exit Signs..................................................................... 50, 51 Wet Location Diecast LED Exit Signs.................................................................................... 52 Recessed Diecast LED Exit Signs........................................................................................... 53 New York Diecast LED Exit Signs......................................................................................... 54 Wet Location LED Exit Signs.....................................................................................55 Aluminum LED Exit Signs..................................................................................................... 56 Low-Profile Aluminum LED Exit Signs. ......................................................................57 New York LED Exit Signs..........................................................................................58 Chicago Exit Signs ...................................................................................................59 Recessed Mounting Edge-Lit LED Exit Signs................................................................ 60, 61 Surface Mounting AC Edge-Lit LED Exit Signs............................................................. 62, 63 New York Recessed Mounting Edge-Lit LED Exit Signs...................................................... 64 New York Surface Mounting Edge-Lit LED Exit Signs......................................................... 65 Special Wording Incandescent Exit Signs...................................................................66 Clearview Emergency Lighting Products Remote Heads, Fixtures and Accessories SlimLite Series CV Series CVEC Series CV3 Series CVT Series CVD Series CVER Series Fixed Lens Emergency Lights...................................................................................68 Emergency Lights....................................................................................................69 High Capacity Emergency Lights...............................................................................70 LED Exit Signs........................................................................................................................ 71 Tandem Units..........................................................................................................72 Diecast LED Exit Signs........................................................................................................... 73 Recessed Mounting Edge-Lit LED Exit Signs....................................................................... 74 Remote Fixtures, Accessories & General Information Inverter Power Systems Remote Heads and Fixtures . .................................................................................................76 to 78 Lamp Selector Guide ....................................................................................................................... 79 Voltage Drop Tables ....................................................................................................................... 80 Unit Accessories . .............................................................................................................................................81 National Electric Code ............................................................................................................................. 82, 83 NFPA 101 Life Safety Code . ................................................................................................................... 84, 85 Limited Warranty ............................................................................................................................ 86 Inverter Power Systems Synchron Series Single-Phase Inverters ......................................................................................... 88 to 91 Spectron LSN Series Single-Phase Inverters ................................................................................92 to 101 Trident Series Three-Phase Inverters ...................................................................................................... 103 to 106 Auxiliary Transfer Switching Device ...................................................................................................................... 107 The following guide provides a fast, easy method of selecting products for most applications. Refer to catalog pages for additional product and ordering information. Emergency Lighting Units Catalog Page Number(s) Product Series 14, 15 LiteScape™ Series Commercial Units 16 EZ-2™ Series Commercial Units 17 LZ Series Low-Profile Halogen Lamp Model Number Unit Voltage Watts For 11/2 Hrs. Battery Type Power Warranty Consumption Battery (Max.)(1) Equipment Full/Pro-Rata LSC LSCN LSCI LSCNI GUARANTEED CODE-COMPLIANCE 6 6 6 6 20 20 20 20 Lead-Calcium Nickel-Cadmium Lead-Calcium Nickel-Cadmium 2 Watts 2 Watts 2 Watts 2 Watts 1 Years 1 Years 5 Years 5 Years EZ-2 EZ-2V EZ-2I 4 4 6 10.8 10.8 14.4 Lead-Calcium “ “ 15 Watts 15 Watts 15 Watts 3 Years 3/3 Years 3 Years 3/3 Years 5 Years 5/5 Years Damp Location Model EZ-2D 4 10.8 Lead-Calcium 15 Watts 3 Years LZ2, LZ2D LZ15 6 6 10 15 Lead-Calcium ” 3.5 Watts ” 1 Year 1/5 Years ” ” Standard Models LZ30 LZ35-12V LZ65 LZ65-12V LZ20N LZ25N-12V 6 12 6 12 6 12 30 35 65 65 20 25 Lead-Calcium 14 Watts ” ” ” ” ” ” Nickel-Cadmium 11.2 Watts ” ” 1 Year 1/5 Years ” ” ” ” ” ” 3 Years 1/9 ” ” Damp Location Models LZ25D LZ30D-12V LZ55D LZ55D-12V LZ15ND LZ20ND-12V 6 12 6 12 6 12 25 30 55 55 15 20 Lead-Calcium 14 Watts ” ” ” ” ” ” Nickel-Cadmium 11.2 Watts ” ” 1 Year 1/5 Years ” ” ” ” ” ” 3 Years 1/9 ” ” 6, 12 6, 12 — — — — — — Standard Models LM2 LM16 LM33 LM40 LM66 LM80 LM130 LM40-12V LM66-12V LM80-12V LM130-12V 6 6 6 6 6 6 6 12 12 12 12 14.4 16 33 40 66 80 130 40 66 80 130 Lead-Calcium “ “ “ “ “ “ “ “ “ “ 15 Watts “ “ “ “ “ “ “ “ “ “ 1 Year 1/5 Years “ “ “ “ “ “ “ “ “ “ “ “ “ “ “ “ “ “ “ “ Damp Location Models LM28D LM34D LM56D LM68D LM112D LM34D-12V LM56D-12V LM68D-12V LM112D-12V 6 6 6 6 6 12 12 12 12 28 34 56 68 112 34 56 68 112 Lead-Calcium “ “ “ “ “ “ “ “ 15 Watts “ “ “ “ “ “ “ “ 1 Year 1/5 Years “ “ “ “ “ “ “ “ “ “ “ “ “ “ “ “ 1/5 Years 1/9 Years 2/4 Years 2/4 Years 3/3 Year Units 18, 19 LZ Series High Capacity Halogen Lamp Units • Choice of battery types • 6- and 12-volt models • Capacities up to 65 watts Remote Lighting Fixtures Single Lamp Models Tandem Lamp Models 20, 21 LM Series Compact, Traditional Design Units • Rugged metal housing • 6- and 12-volt models • Capacities up to 130 watts • Lighting heads may be top or side mounted 1 Year 1 Year — — (1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power consumption ratings on specific models. Quick Selector Guide Emergency Lighting Units Catalog Page Number(s) Product Series Model Number Unit Voltage Watts For 11/2 Hrs. 20, 21 LM Series Special Application NiCad Battery Models 14.4 Models LM15N 6 LM30N 6 30 LM50N 6 50 LM50N-12V 12 50 LM100N-12V 12 100 • Rugged metal housing • 6- and 12-volt models • Capacities up to 100 watts Battery Type Power Warranty Consumption Battery (Max.)(1) Equipment Full/Pro-Rata Nickel-Cadmium “ “ “ “ 15 Watts “ “ “ “ 3 Years 1/9 Years “ “ “ “ “ “ “ City of Chicago Models LM24CH LM36CH LM36CH-12V 6 6 12 24 36 36 Lead-Calcium “ “ 15 Watts “ “ 1 Year 1/5 Years “ “ “ “ EZ-2R EZ-2RI 6 6 10.8 14.4 Lead-Calcium “ 15 Watts 15 Watts 3 Years 3/3 Years 5 Years 5/5 Years TG15 TG30 TG50-12V TG15N TG30N TG50N-12V 6 6 12 6 6 12 15 30 50 15 30 50 Lead-Calcium ” ” Nickel-Cadmium ” ” 15 Watts 75 Watts ” 15 Watts 75 Watts ” 3 Years 3/3 Years ” ” ” ” 3 Years 1/9 Years ” ” ” ” EXT-122-EM-K 6 8 Lead-Calcium 15 Watts 1 Year 1/5 Years 25 LITE2™ Series Square Units urface, semi-recessed • Sand fully-recessed models EDS EDS-2 ERS ERS-3 ERS-2-2 ESS-I ESS-I-2 ERS-I ERS-3I ERS-2I-2 6 6 6 6 6 6 6 6 6 6 10 14.4 20 30 30 10 14.4 20 30 30 Lead-Calcium ” ” ” ” Lead-Calcium ” ” ” ” 12 Watts ” ” ” ” 12 Watts ” ” ” ” 3 Years 3/3 Years ” ” ” ” ” ” ” ” 5 Years 5/5 Years ” ” ” ” ” ” ” ” 26 DELITE® Series Cylinder Units ESC-2-0 6 12 Lead-Calcium 15 Watts 1 Years 1/5 Years N4X2 N4X4 N4X7 N4X14 6 6 6 6 15.6 31.2 50.4 100 Lead-Calcium ” ” ” 75 Watts ” ” ” 3 Years 3/3 Years ” ” ” ” ” ” N4X7-12V N4X14-12V 12 12 50.4 100 ” ” ” ” • Lighting heads may be top or side mounted • Chicago Models 22 EZ-2R™ Series Recessed Mounting Units • Ceiling or wall mount 23 T-Grid™ Series Recessed Troffer Units • Suspended ceiling mount 24 EXT™ Series Recessed Gimbal Unit 27 N4X Series Sealed, Harsh Environment Unit • Dust-tight, moisture and corrosion resistant ” ” ” ” (1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power consumption ratings on specific models. Emergency Lighting Units Catalog Page Number(s) Product Series 28, 29 AS Series Traditional Model Number AS-80 AS-130 Voltage 6 6 AS-180-12V AS-270--12V AS-360-12V 12 12 12 180 270 360 ” ” ” ” ” ” ” ” ” ” ” ” • Maintenance-free batteries AS-180-24V AS-270-24V AS-360-24V 24 24 24 180 270 360 ” ” ” ” ” ” ” ” ” ” ” ” 28, 29 ALC-X/EDC-X Series Traditional Units ALC-X-30 ALC-X-60 ALC-X-100 6 6 6 78 144 162 Wet-Cell Lead-Calcium ” 75 Watts ” ” 12EDC-X-36S 12EDC-X-60S 12EDC-X-120S 12 12 12 200 240 350 ” ” ” ” ” ” AS-75 AS-145 AS-210 6 6 6 75 110 145 Wet-Cell Nickel-Cadmium ” 75 Watts ” ” • Longest life, 12EDN-10S 12EDN-18S 12EDN-30S 12 12 12 48 100 150 ” ” ” ” ” ” ” ” ” ” ” ” 30, 31 IPS Series NEC Class I, C1D2-6V36 C1D2-6V72 6 6 36 72 Pure-Lead “ 25 Watts “ 3 “ 3/3 “ • Suitable for C1D2-12V36 C1D2-12V72 12 12 36 72 “ “ “ “ “ “ “ “ 32, 33 XPB Series ExplosionProof Units XPB-75P 12XPB-75P 6 12 75 75 Pure-Lead ” 75 Watts ” Units • Wet-cell lead-calcium batteries 28, 29 AS/EDN Series Traditional Units wet locations Watts Power Warranty For Battery Consumption Battery 11/2 Hrs. Type (Max.)(1) Equipment Full/Pro-Rata 80 Lead-Calcium 75 Watts 1 Year 1/5 Years 130 ” ” ” ” 1 Year 1/9 Years ” ” ” ” ” ” ” ” ” ” Note: 12EDC-X models supplied without lighting heads. wet-cell nickel-cadmium Note: 12EDN models supplied batteries without lighting heads. Division 2 Units Unit 1 Year 1/14 Years ” ” ” ” 3 Years 3/3 Years ” ” • NEC Class I and II operation • Unit mounted and remote fixtures (1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power consumption ratings on specific models. Fluorescent Power Packs Catalog Page Number(s) Product Series 34 LAMPAK® Series Fluorescent Packs • Models standard for fluorescent lamps Model Number UFO-3AW UFO-4W UFO-5W UFO-5AW UFO-6W UFO-6WI UFO-6W-CLD 35 LAMPAK® Series Fluorescent Packs UFO-7W UFO-7WI • High lumen output models Operates Lamp Type Std. Fluor. Std. Fluor. Std. Fluor. Std. Fluor. Std. Fluor. Std. Fluor. Std. Fluor. Rating I n Battery Lumens Type 350-450 Nickel-Cadmium 500-600 ” 600-700 ” 600-700 ” 1100-1400 ” 1100-1400 ” 600-750 ” Std. Fluor. 1450-3500 Nickel-Cadmium Std. Fluor. 1800-3500 “ Number Warranty Of Lamps Battery Operated Equipment Full/Pro-Rata 1 1 Year 1 Year 1 ” ” 1 ” ” 1 or 2 ” ” 1 or 2 ” ” 1 or 2 ” ” 1 or 2 ” ” 1 or 2 1 or 2 1 Year “ 1 Year “ Quick Selector Guide Fluorescent Power Packs Catalog Page Number(s) Product Series Model Number Operates Lamp Type Rating I n Lumens Battery Type Number Warranty Of Lamps Battery Operated Equipment Full/Pro-Rata 36 LAMPAK® Series UFO-12W Fluorescent Packs • For compact fluorescent lamps 13 to 42W 300-750 Nickel-Cadmium Compact Fluor. Lamps 1 or 2 1 Year 1 Year LAMPAK® Series UFO-LP1 37 Fluorescent UFO-LP2 Packs • For low-profile T5 and T8 390-700 Nickel-Cadmium Fluor. 650-1325 “ Lamps 1 1 1 Year “ 1 Year “ 38 LAMPAK® Series HID Back-up Ballast • For metal- Metal- 20 to 30% Nickel-Cadmium Halide Normal “ HID Lamps Output “ 1 1 1 1 Year “ “ 1 Year “ “ fluorescent fixtures UFO-MH175 UFO-MH250 UFO-MH400 halide HID lamps Exit Signs Catalog Page Number(s) Product Series AC Lamp Type AC Lamp Wattage DC Lamp Type Battery Type Power Warranty Consumption Battery (Emerg. Max.)(1) Equipment Full/Pro-Rata 40 LX Series LED Red – 2.6W LED Nickel-Cadmium 3.8 Watts Thermoplastic Green – 2.1W LED Exit Signs 5 Years 1/9 Years • All models Damp Location Listed 41 DK Series Incandescent 15W (2) — — 30 Watts Thermoplastic Incandescent Exit Signs 3 Years Excluding AC Lamps — 42, 43 LT Series LED Red – 2.6W Halogen Lead-Calcium 5.0 Watts 5 Years 1/5 Years Combination Green – 2.1W and Emergency LED Unit/LED Exit Signs • Damp Location and Remote Capacity models 44 NYXC Series LED Red –3.5W LED Lead-Calcium 7.0 Watts Combination Green – 3.0W Emergency Unit/LED Exit 5 Years 1/5 Years Signs • Meets NY City requirements 45 SMC Series LED Red – 2.6W LED Lead-Calcium 12 Watts Combination Green – 2.1W Emergency Unit/LED Exit 3 Years 1/5 Years Signs • Low-profile side mounted lighting heads (1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power consumption ratings on specific models. Exit Signs Catalog Page Number(s) Product Series AC Lamp Type AC Lamp Wattage DC Lamp Type Battery Type Power Warranty Consumption Battery (Emerg. Max.)(1) Equipment Full/Pro-Rata 46, 47 Sempra® Series LED Red – 2.6W LED Nickel-Cadmium 3.8 Watts Cast Aluminum Green – 2.1W LED Exit Signs 5 Years 1/9 Years (Lifetime on LED strip) • Lifetime warranty on LED lamp strip Sempra® MR Series LED Red – 2.6W (2) LED Nickel-Cadmium 3.8 Watts 48, 49 Master/Remote Green – 2.1W (2) Cast Aluminum LED Exit Signs 5 Years 1/9 Years (Lifetime on LED strip) • Supplied as 2-sign sets • Low-profile Remote exit • Lifetime warranty on LED lamp strip Sempra® SC Series LED Red – 2.6W LED Nickel-Cadmium 3.8 Watts 50, 51 Severe Conditions Green – 2.1W Cast Aluminum LED Exit Signs 5 Years 1/9 Years (Lifetime on LED strip) • Lifetime warranty on LED lamp strip 52 Sempra® SCWL Series LED Red – 2.6W LED Nickel-Cadmium 3.8 Watts Wet Location Cast Green – 2.1W Aluminum LED Exit Signs 5 Years 1/9 Years (Lifetime on LED strip) • Completely sealed and gasketed • Lifetime warranty on LED lamp strip 53 Sempra® SERS Series LED Red – 2.6W LED Nickel-Cadmium 3.8 Watts Recessed Cast Green – 2.1W Aluminum LED Exit Signs 5 Years 1/9 Years (Lifetime on LED strip) • Lifetime warranty on LED lamp strip 54 NYDC Series LED Cast Aluminum LED Exit Signs Red – 2.5W LED Nickel-Cadmium 3.5 Watts 5 Years 1/9 Years • Meets NY City requirements 55 LN4X Series LED Red – 2.6W LED Nickel-Cadmium 3.8 Watts 5 Years 1/9 Years Wet Location Green – 2.1W LED Exit Signs • Suitable for damp, wet and corrosive environments Single Face 56 Freedom® LED Series LED LED Lead-Acid 7.7 Watts 5 Years 1/4 Years Red – 4.5W Aluminum LED Exit Signs Green – 4.7W Double Face Red – 6.8W Green – 6.7W • Up to 12 hours of emergency operation • All models Damp Location Listed (1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power consumption ratings on specific models. 10 Quick Selector Guide Exit Signs Catalog Page Number(s) Product Series AC Lamp Type AC Lamp Wattage DC Lamp Type Battery Type Power Warranty Consumption Battery (Emerg. Max.)(1) Equipment Full/Pro-Rata 57 LEDS Series LED Red – 3.2W LED Nickel-Cadmium 3.3 Watts Low-Profile Green – 2.9W Aluminum LED Exit Signs • All models Damp Location Listed NYX Series LED Red – 2.4W LED Nickel-Cadmium 3.5 Watts 58 New York City LED Exit Signs 5 Years 1/9 Years • Meets NY City requirements 59 CMX Series Chicago Exit Signs 5 Years 1/9 Years Incandescent Incand.– 20W (2) 5W (2) Lead-Calcium Incand.– 50W or Fluor.– 9W (2) Fluor.– 28W Fluorescent 5 Years 1/9 Years • City of Chicago approval No. 9823 Single Face 60, 61 LE Series LED LED Nickel-Cadmium 3.8 Watts Recessed Edge-Lit Red – 2.2W LED Exit Signs Green – 2.5W 5 Years 1/9 Years Double Face Red – 3.4W Green – 4.0W • Choice of six • Universal recess rough-in kit decorator finishes Single Face 62, 63 LES Series LED — — Red – 2.2W Surface Mount Edge-Lit LED Green – 2.5W AC Exit Signs • Wall-, ceiling- and end-mount models 4.0 Watts 5 Years 1/9 Years Double Face Red – 3.4W Green – 4.0W • Choice of six decorator finishes NYE Series LED Red – 3.2W LED Nickel-Cadmium 4.0 Watts 64 NYC Recessed Edge-Lit LED Exit Signs 5 Years 1/9 Years • Ceiling or wall recess installation • Meets NY City requirements NYES Series LED Red – 3.2W — Nickel-Cadmium 65 NYC Surface Mount Edge- 4.0 Watts 5 Years 1/9 Years 66 DEX Series Incandescent 15W (2) 3.7W (2) Lead-Calcium 35 Watts Special Wording Incandescent Incandescent Exit Signs 3 Years 1/5 Years Excluding AC Lamps Lit LED Exit Signs • Wall-, ceiling- and end-mount models • Meets NY City requirements (1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power consumption ratings on specific models. 11 Quick Selector Guide Emergency Lighting Products Catalog Page Number(s) Product Series 68 SlimLite Series Contemporary Unit 69 CV Series Designer Units • Standard and damp location models 70 CVEC Series Commercial Units • 6- and 12-volt models • Capacities up to 100 watts • Lighting heads may be top or side mounted Catalog Page Number(s) Product Series Model Number SL1, SL1-V Unit Voltage Watts For 11/2 Hrs. Battery Type Power Warranty Consumption Battery (Max.)(1) Equipment Full/Pro-Rata 6 12 Lead-Calcium 3.5 Watts 1 Year 1/5 Years Standard Models CV2 CV3 CV5 Damp Location Models CV2D CV3D CV5D 6 6 6 12 18 30 Lead-Calcium ” “ 4 Watts ” 14 Watts 1 Year 1/5 Years ” ” “ “ 6 6 6 12 18 30 Lead-Calcium ” “ 4 Watts ” 14 Watts 1 Year 1/5 Years ” ” “ “ CVEC15 CVEC30 CVEC50 CVEC50-12V CVEC100-12V 6 6 6 6 6 15 30 50 50 100 Lead-Calcium ” “ ” “ 9 Watts 9 Watts 20 Watts 14 Watts 39 Watts 1 Year 1/5 Years ” ” “ “ ” ” “ “ AC Lamp Type AC Lamp Wattage DC Lamp Type Battery Type Power Warranty Consumption Battery (Emerg. Max.)(1) Equipment Full/Pro-Rata 71 CV3 Series LED Red – 2.6W LED Nickel-Cadmium 3.8 Watts Thermoplastic Green – 2.1W LED Exit Signs 5 Years 1/9 Years 72 CVT Series LED Red – 2.6W Halogen Lead-Calcium 5.0 Watts Combination Green – 2.1W and Emergency LED Unit/LED Exit Signs 5 Years 1/9 Years Excluding AC Lamps 73 CVD Series LED Cast Aluminum LED Exit Signs Red – 2.6W LED Nickel-Cadmium 3.8 Watts Green – 2.1W 5 Years 1/9 Years 74 CVER Series LED Red –2.5W LED Nickel-Cadmium 5.2 Watts Recessed Green – 3.0W Mount Edge Lit LED Exit Signs 5 Years 1/9 Years (1) Maximum power consumption specification shown for circuit-sizing purposes only. Normal operating power requirements are significantly lower. Consult factory for normal operating power consumption ratings on specific models. Inverter Power Systems Catalog Page Number(s) Product Series 88 to 91 92 to 101 103 to 104 105 to 106 12 Synchron Series Spectron LSN Trident TRX Series Trident TRN Series System Type System Output Capacities Single Phase 400 to 2100VA Single Phase 1.0 to 17.5kVA Three Phase 10 to 30kVA Three Phase 30 to 130kVA Emergency Lighting Units LiteScape Series EZ-2 Series LZ Series LZ (HC) Series LM Series EZ-2R Series T-Grid Series EXT Series Lite2 Series Delite Series N4X Series AS Series IPS Series XPB Series Lampak Series Guaranteed Code Compliant Emergency Lights................. 14, 15 Commercial Emergency Lights. ............................................... 16 Designer Emergency Lights.............................................................17 High Capacity Designer Emergency Lights......................... 18, 19 21 Recessed Emergency Lights.............................................................22 Recessed T-Grid Emergency Lights........................................... 23 Recessed Gimbal Emergency Light........................................... 24 Emergency Lighting Square Units. ..................................... 25 Emergency Lighting Cylinder Units.......................................... 26 Harsh Environment Emergency Lights...................................... 27 Industrial Emergency Lights............................................. 28, 29 Wet Location Emergency Lights. ...................................... 30, 31 Explosion-Proof Emergency Lights.................................... 32, 33 Fluorescent Power Packs.............................................. 34 to 38 High Capacity Emergency Lights....................................... 20, 13 LiteScape Commercial Emergency Light Features • Factory guaranteed NFPA-101 code-compliant illumination W Field adjustable 3 ft. x 40 ft. or • NE 6 ft. x 30 ft. egress illumination patterns • SurePath® technology delivers bright, continuous illumination • Low-profile silhouette • Fast, easy installation • High-output, 6 volt, 10-watt halogen lamps • Impact resistant, UV stable polycarbonate construction GUARANTEED CODE• Unit housing is paintable COMPLIANT ILLUMINATION • Lead-acid or nickel-cadmium rdering nformationbattery models O I 20W • Universal 120/277VAC operation • AC lockout • Available with Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard • Low-voltage battery disconnect • Test switch and AC-On indicator • Temperature range: Lead-acid models = 20°C to 30°C (68°F to 86°F) Nickel-Cadmium models = 0°C to 40°C (32°F to 104°F) • UL 924 Listed (Emergency Lighting) • UL Damp Location Listed (Nickel-Cadmium models only) Ordering Information Nickel-Cadmium Standard Model Nickel-Cadmium Model Spectron Self-Testing Model Spectron Self-Testing Model ptions (Add suffix to model) ccessories (Order Separately) LSC LSCN LSCI LSCNI O A Options -24K -AA (Add suffix to model) 220/240VAC, 60Hz. operation Audible alarm (1) (1) For use with LSCI and LSCNI self-testing/self-diagnostic models only. Patented reflector design produces bright, evenly illuminated “SurePath™” egress lighting pattern SurePathTM Technology The heart of LiteScape’s SurePath technology is the patent pending reflector design created exclusively for Dual-Lite by Breault Research Organization, the company selected to correct the optics for the Hubble space telescope. This unique reflector design coupled with the unit’s two high-output, 10-watt halogen lamps provide an incredibly bright and evenly distributed illumination pattern. Additionally, a user-selectable reflector adjustment allows a choice of the 3’ or 6’ wide SurePath illumination patterns. The long, broad and even nature of the SurePath illumination pattern makes it the optimum method of lighting interior paths of egress during emergency conditions. Dimensions 81/2” Housing is field paintable to match wall decor. 11” 14 1 2” 3/ LiteScape The LiteScape Performance Guarantee Dual-Lite guarantees the LiteScape unit will fully meet the 2003 edition of the NFPA 101 Life Safety Code emergency lighting requirements by providing an average of one footcandle of illumination along the path of egress as defined in the illustration below. Center to Center Mounting Information 7.5 ft. 3-Foot Wide Standard Illumination Path Setting = 40 Foot Centers 6-Foot Wide Optional Illumination Path Setting = 30 Foot Centers NOTE: The LiteScape unit must be installed per factory instructions provided and properly maintained. In addition, the pathway to be illuminated must meet the minimum surface reflectance values shown at right to qualify for guaranteed illumination performance. Minimum Reflectance Values Required: Ceiling: 80% Walls: 50% Floor: 20% The LiteScape Performance Guarantee applies solely to units mounted 7.5 feet above the floor surface. For information on lighting performance at other mounting heights, refer to LiteScape Series Mounting Guide on the LiteScape product page in the Dual-Lite web site’s on-line catalog. The LiteScape Performance Guarantee is subject to all conditions as outlined in the Product Warranty Statement on the Dual-Lite public web site (www.dual-lite.com) and applies only to the installation’s initial emergency lighting inspection by the authority having jurisdiction. Photometrics 3-Foot Standard Illumination Path Setting (40-Foot Mounting Centers) 6-Foot Optional Illumination Path Setting (30-Foot Mounting Centers) 1) Photometric illustrations based on data provided by Independent Testing Laboratories (ITL), Boulder, Colorado. 2) Photometrics shown based on 7.5-foot mounting height and minimum 80-50-20 reflectance values. 3) The white rectangular area in photometric illustrations represents normal center to center SurePath egress illumination pattern provided. Independent Verification The photometric data shown above was generated and verified by Independent Testing Laboratories (ITL) of Boulder, Colorado. LiteScape IES photometric files can be downloaded from the LiteScape product page at www.dual-lite.com. LiteScape illumination data has also been incorporated into the Hubbell LitePro® lighting design application software. 15 EZ-2 Commercial Emergency Lights Features An Damp Severe Conditions Product • Easy to install • Compact, low-profile design • Flame-rated, UV-stable thermoplastic housing • Textured, bright white finish • Universal mounting plate • Glare-free, adjustable lampheads • Maintenance-free battery • Universal 120/277VAC operation • Low power consumption • Fully-automatic charger • AC lockout 10.8W, 14.4W • Low-voltage battery disconnect • Transformer isolation protection • Test switch and AC-On light • Available with Spectron® selftesting/self-diagnostic electronics with time-delay relay (TDR) standard • Damp location model available • Temperature range: 20°C to 30°C (68°F to 86°F) Damp location EZ-2D: 0°C - 40°C (32°F to 104°F) • UL 924 Listed (Damp Location Model EZ-2D) Ordering Information Standard Model EZ-2 Options -A21 Damp Location Model EZ-2-D (Add Voltmeter Model EZ-2-V Spectron Self-Testing Model EZ-2I Accessories suffix to model) (Order Separately) Vandal resistant shield VRS WGEL Wire guard Auxiliary 2-conductor AC line cord (120V only) Product Selector Guide Electrical Base Catalog Number Output Watts Output 1.5 2 3 4 Volts Hours Hours Hours Hours AC Input Standard Remote Volts Amps Watts Lamp Capability EZ-2, EZ-2-D 6 10.8 -- -- - and EZ-2-V 120 .080 8.4 277 .030 8.8 120 .080 8.4 277 .030 8.8 14.4 -- -- - EZ-2I* 6 5.4W No 7.2W No * Includes Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard Photometrics Horizontal Isofootcandle Distribution 6 Volt, 5.4 Watt SBT Lamp 6 Volt, 7.2 Watt SBT Lamp Dimensions 14” (35.5 cm) 5” (12.7 cm) 5” (12.7 cm) 16 Designer Emergency Lights Features • Easy to install • Flame-rated, UV-stable thermoplastic housing • White or black finishes • Slim, low-profile snap-together design • Standard and damp location models • Low profile, adjustable lampheads • High-output halogen lamps • Clear glass protective lamp lens • Matching remote fixtures • 120/277VAC operation standard • Fully-automatic charger LZ 10W • Maintenance-free battery • 90 minute operation • Low-voltage battery disconnect • Transformer isolation protection • Test switch and AC-On light • Available with Spectron® selftesting/self-diagnostic electronics with time-delay relay (TDR) standard • Temperature range: 20°C to 30°C (68°F to 86°F) Damp location model: 10°C to 40°C (50°F to 104°F) • UL 924 Listed Ordering Information See Product Selector Guide below for available models Matching remote lighting head Outdoor lighting head Options (Add Accessories suffix to model) I -B -V -24K -A21 Spectron self-testing/self-diagnostic electronics Black finish Voltmeter 220-240VAC, 60 Hz. operation Auxiliary 2-conductor line cord (120V only) (1) -A31 Auxiliary 3-conductor line cord (120V only) (2) (3) VRS WGLZ PMLZTW PMLZTB LZRSW0605 LZRSB0605 OMSSW0605 OMSSB0605 (1) Not for use with LZ15 model. (2) For use with LZ15 model only. (3) Not available with LZ2 model. (Order Separately) Vandal resistant shield Wire guard 121/2” Pendant mounting kit - white 121/2” Pendant mounting kit - black Matching remote lighting head - white Matching remote lighting head - black Outdoor lighting head - 6 Volt, 5 Watt sealed beam type lamp - White finish Outdoor lighting head - 6 Volt, 5 Watt sealed beam type lamp - Black finish Product Selector Guide Base Catalog Numbers Output Volts LZ2 LZ2D* LZ15 6 6 6 Electrical O utput Watts 1.5 2 3 4 Hours Hours Hours Hours 10 10 15 -- -- 12 -- -- -- -- -- -- Standard Lamp Remote Capability 5W Hal. 5W Hal. 5W Hal. No No Yes Photometrics Dimensions High-Output Halogen Lamp Also available in black finish Horizontal Isofootcandle Distribution 3 5/8” (9.2cm) 17 LZ Designer Emergency Lights Features High Capacity An Severe Conditions Product Line Damp (Damp Location Models) • Easy to install • Capacities up to 65 watts • 6- and 12-volt models • Flame-rated, UV-stable thermoplastic housing • White or black finishes • Snap-together design • Standard and damp location models • Low profile lampheads • High-output halogen lamps • Clear glass protective lamp lens • Matching remote fixtures • 120/277VAC operation standard 15W to 65W • Fully automatic charger • Choice of maintenance-free battery types • Low-voltage battery disconnect • Transformer isolation protection • Test switch and AC-On light • Available with Spectron® selftesting/self-diagnostic electronics with time-delay relay (TDR) standard • Temperature range: 20°C to 30°C (68°F to 86°F) Damp location model: 10°C to 40°C (50°F to 104°F) • UL 924 Listed Ordering Information See Product Selector Guide for available models Options I -B -V -10W -0 -24K -A31 (Add Accessories suffix to model) Spectron self-testing/self-diagnostic electronics Black finish Voltmeter 10-watt halogen lamps (1) Unit supplied without lampheads 220-240VAC, 60 Hz. operation Auxiliary 3-conductor line cord (120V only) (1) Available on units with capacities of 20 watts or more. (Order Separately) VRS Vandal resistant shield WGEL Wire guard LZRSW0605 Matching remote lighting head - white LZRDSB0605 Matching remote lighting head - black OMSSW0605 Outdoor lighting head - 6 Volt, 5 Watt sealed beam type lamp - White finish OMSSB0605 Outdoor lighting head - 6 Volt, 5 Watt sealed beam type lamp - Black finish OMSSW1205 Outdoor lighting head - 12 Volt, 5 Watt sealed beam type lamp - White finish OMSSB1205 Outdoor lighting head - 12 Volt, 5 Watt sealed beam type lamp - Black finish Outdoor Lighting Heads Matching Remote Lighting Heads Also available in black finish Matching Remote Fixtures Photometrics High-Output Halogen Lamp Horizontal Isofootcandle Distribution Standard 5W MR-16 Lamp Optional 10W MR-16 Lamp A complete line of 6- and 12-volt matching remote fixtures in single and tandem lamp configurations is available for use with LZ Series high-capacity units or any other 6- or 12-volt DC emergency lighting remote power sources. All remote fixtures are offered in black and white textured finishes with a choice of 5- or 10-watt halogen lamps. White Black 18 Single Tandem Single Tandem Volts Watts LZRSW0605 LZRDW0605 LZRSB0605 LZRDB0605 6 5 LZRSW0610 LZRDW0610 LZRSB0610 LZRDB0610 6 10 LZRSW1205 LZRDW1205 LZRSB1205 LZRDB1205 12 5 LZRSW1210 LZRDW1210 LZRSB1210 LZRDB1210 12 10 LZ Product Selector Guide High Capacity Standard Models Electrical Base Catalog Numbers LZ30 LZ35-12V LZ65 LZ65-12V LZ20N LZ25N-12V Output Volts Battery Type 6 12 6 12 6 12 Lead-Calcium Lead-Calcium Lead-Calcium Lead-Calcium Nickel-Cadmium Nickel-Cadmium Output Watts 1.5 2 3 4 Standard Hours Hours Hours Hours Lamp 30 35 65 65 20 25 24 26 49 49 15 19 15 18 33 33 10 13 12 14 26 26 8 10 5W Hal. 5W Hal. 5W Hal. 5W Hal. 5W Hal. 5W Hal. Remote Capability Yes Yes Yes Yes Yes Yes Damp Location Models Electrical Base Catalog Numbers Output Volts LZ25D LZ30D-12V LZ55D LZ55D-12V LZ15ND LZ20ND-12V 6 12 6 12 6 12 Battery Type Lead-Calcium Lead-Calcium Lead-Calcium Lead-Calcium Nickel-Cadmium Nickel-Cadmium Output Watts 1.5 2 3 4 Standard Hours Hours Hours Hours Lamp 25 30 55 55 15 20 19 24 42 42 11 15 13 15 28 28 8 10 10 12 22 22 6 8 5W Hal. 5W Hal. 5W Hal. 5W Hal. 5W Hal. 5W Hal. Remote Capability Yes Yes Yes Yes Yes Yes Dimensions 5 1/8” (13 cm) 19 LM High Capacity Emergency Lights Features • Easy to install • Universal wall mounting pattern • White, corrosion-resistant metal housing and front-loading cover • Maintenance-free battery • 6- & 12-volt models • Damp location models available • Glare-free lampheads • Lampheads may be top or side mounted An • Available with 3 or 4 lampheads • Available without lampheads Severe Conditions Product Line • Matching remote fixtures (1) Damp Location • 120/277VAC operation standard Models Only (1) (220-240VAC, 60 Hz. optional) (2) Damp Hot Cold(2) (2) NiCad Models Only rdering nformation O I Example: LM130-3 14W to 130W • Fully automatic, solid-state charger • Low-voltage battery disconnect • Transformer isolation protection • Test switch and AC-On light • Available with Spectron® selftesting/self-diagnostic electronics with time-delay relay (TDR) standard • 90 minute operation • Temperature range: 20°C to 30°C (68°F to 86°F) NiCad models: 20°C - 30°C (68°F to 86°F) Damp location models: 10°C to 40°C (50°F to 104°F) • UL 924 Listed Ordering Information See Product Selector Guide for available models Options Options I -V -3 -4 -0 -A31 -A32 -24K (Add suffix to model) (Add suffix to model) Accessories Accessories (Order Separately) (Order Separately) Spectron self-testing/self-diagnostic electronics( 1)(5) 40G Wire guard (Top mounted heads only) Voltmeter SRHSW Single matching remote head - white * (1)(2) Unit supplied with three lampheads SRHDW Twin matching remote head - white * (1)(2) * Supplied with round mounting plate. Specify voltage and wattage when Unit supplied with four lampheads ordering. Example: SRHDW1212. See “Remote Heads and Fixtures” section for available lamps. Unit supplied without lampheads (1)(2)(3) Auxiliary 3-conductor AC line cord (120V) Auxiliary 3-conductor AC line cord (277V) 220-240VAC, 60Hz. operation (4) (1) Not available with LM2 model. (2) Not available with LM16 model. (3) NOTE: Spectron models with over 80 watts of capacity require a minimum load of 35 watts for accurate lamp failure indications. (4) Not available on units with capacities over 80 watts for 1.5 hours. SRH Series Matching Remote Lighting Heads (5) Spectron not available with Nickel-Cadmium battery models. Optional Lamps To order two nonstandard lamps on the fixture, suffix catalog number. See “Remote Heads and Fixtures” section for available lamps. Example: LM33-SRHSW0612. Dimensions F E C Photometrics B Horizontal Isofootcandle Distribution 6 Volt, 7.2 Watt SBT Lamp D 12 Volt, 7.2 Watt SBT Lamp Enclosure Style A 20 7 A B C D E 3 1 1 F 3 1 3 /8” 5 /4” 11 /2” 13 /2” 15 /4” 25” 9.8 cm 14.6 cm 29.3 cm 34.3 cm 40.0 cm 63.5 cm 2 4 3/4” 7 3/4” 13 1/2” 15 3/4” 18” 27 1/4” 12.1 cm 19.7 cm 34.3 cm 40.0 cm 45.7 cm 69.2 cm LM Product Selector Guide Standard Models (1) Catalog Numbers LM2 LM16 LM33 LM40 LM66 LM80 LM130 LM40-12V LM66-12V LM80-12V LM130-12V Enclosure Style Output Volts 1 1 1 1 2 2 2 1 2 2 2 6 6 6 6 6 6 6 12 12 12 12 Electrical Output Watts 1.5 2 3 4 Hours Hours Hours Hours 14.4 16 33 40 66 80 130 40 66 80 130 — — 25 31 51 62 101 31 51 62 101 — — 17 21 35 43 70 21 35 43 70 — — 13 16 27 33 54 16 27 33 54 Standard Remote Lamp Capability 7.2W 7.2W 7.2W 7.2W 7.2W 7.2W 7.2W 7.2W 7.2W 7.2W 7.2W No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Standard Lamp Remote Capability 7.2W 7.2W 7.2W 7.2W 7.2W No Yes Yes Yes Yes Standard Lamp Remote Capability 7.2W 7.2W 7.2W 7.2W 7.2W 7.2W 7.2W 7.2W 7.2W Yes Yes Yes Yes Yes Yes Yes Yes Yes Standard Lamp Remote Capability 12W 12W 12W No Yes Yes (1) Meets New York City Requirements Nickel-Cadmium Models (1) Catalog Numbers LM15N LM30N LM50N LM50N-12V LM100N-12V Enclosure Style Output Volts 1 1 1 1 1 6 6 6 12 12 Electrical Output Watts 1.5 2 3 4 Hours Hours Hours Hours 14.4 30 50 50 100 -- 25 42 42 85 -- 17 29 29 59 -- 13 22 22 46 (1) Meets New York City Requirements Damp Location Models (1) Catalog Numbers LM28D LM34D LM56D LM68D LM112D LM34D-12V LM56D-12V LM68D-12V LM112D-12V Enclosure Style Output Volts 1 1 2 2 2 1 2 2 2 6 6 6 6 6 12 12 12 12 Electrical Output Watts 1.5 2 3 4 Hours Hours Hours Hours 28 34 56 68 112 34 56 68 112 21 26 43 53 87 26 43 53 87 15 18 30 36 60 18 30 36 60 11 14 23 28 47 14 23 28 47 (1) Meets New York City Requirements All Metal City Of Chicago Models (2) Catalog Numbers LM24CH LM36CH LM36CH-12V Enclosure Style Output Volts 1 1 1 6 6 12 Electrical Output Watts 1.5 2 3 4 Hours Hours Hours Hours 24 36 36 -- 26 26 -- -- -- -- -- -- (2) 2000 Chicago Building Code compliant 21 EZ-2R Recessed Emergency Lights Features • Easy installation in wall or ceiling • Compact, low-profile design • All metal recessed housing • Flame-rated, thermoplastic lamp housing and mounting plate • Maintenance-free battery • Glare-free lampheads • 120/277VAC operation standard • Fully automatic, solid-state charger 10.8W, 14.4W • Low-voltage battery disconnect • Transformer isolation protection • Test switch and AC-On light • Available with Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard • 90 minute operation • Temperature range: 20°C to 30°C (68°F to 86°F) • UL 924 Listed Ordering Information Standard Model EZ-2R Spectron Self-Testing Model EZ-2RI A (Orderto Separately Occessories ptions (Add suffix model) ) Wall mounted EZ-2R unit Accessories (Order Separately) F-CBM Troffer mounting kit (suspended ceilings) WGEL Wire guard EZ-2R suspended ceiling installation using F-CBM accessory kit Product Selector Guide Electrical Base Catalog Number EZ-2R Output Volts Output Watts 1.5 2 3 Hours Hours Hours 6 10.8 — 4 Hours Standard Lamp Remote Capability — 5.4W No 7.2W No — 14.4 — — — EZ-2RI* 6 * Includes Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard Dimensions Photometrics E D G F Horizontal Isofootcandle Distribution 6 Volt, 5.4 Watt SBT Lamp A 5 3/4” (14.6 cm) B 11” (27.9 cm) C 3 7/8” (9.8 cm) D 7 3/4” (19.7 cm) E 9 1/8” (23.2 cm) F 5” (12.7 cm) G 6 1/8” (15.6 cm) C 6 Volt, 7.2 Watt SBT Lamp A B Photometrics measured by independent testing laboratory 22 Recessed T-Grid Emergency Lights Features • Easy to install T-Grid lay-in design • Maintenance-free battery • 6 and 12 volt models • Heavy 20 gauge steel housing • Standard white finish • Standard with two glare-free lampheads • Dual voltage – 120V/277VAC • Fully automatic, solid-state charger • Thermally compensated charger • Regulated charge voltage T-Grid 15W to 50W • Automatic low voltage disconnect • Reverse polarity protection • Filtered charger output • Short circuit protection • AC lockout • Test switch and AC-On light • Available with Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard • Temperature range: 20°C to 30°C (68°F to 86°F) • UL 924 Listed Ordering Information Standard Models NiCad Battery Models Options I -V -3 -0 (Add TG15 TG15N TG30 TG50-12V TG30N TG50N-12V Accessories suffix to model) (Order Separately) SRHSW Matching remote head - single * SRHDW Matching remote head - twin * (1) Spectron self-testing electronics Voltmeter Unit supplied with three lighting heads (2) Unit supplied with no lighting heads * Supplied with round mounting plate. Specify voltage and wattage when ordering. Example: SRHSW1212. See “Remote Heads and Fixtures” section for available lamps. (1) Spectron not available with NiCad battery models. (2) Not available on TG15 and TG15N models. SRH Series Matching Remote Lighting Heads Optional Lamps To order two nonstandard lamps on the fixture, suffix catalog number. See “Remote Heads and Fixtures” section for available lamps. Example: TG30-SRHSW0612. Product Selector Guide Electrical NiCad Output Watts Standard Battery Output 1.5 2 3 4 Models Models Volts Hours Hours Hours Hours TG15 TG15N 6 15 11 8 6 TG30 TG30N 6 30 22 15 12 TG50-12V TG50N-12V 12 50 38 25 20 AC Input* Volts Amps Watts 120 277 120 277 120 277 .064 (.070) .029 (.032) .064 (.114) .029 (.051) .120 (.250) .051 (.108) 7.0 (7.6) 7.4 (8.0) 7.0 (12.3) 7.4 (12.7) 12.6 (27.0) 12.9 (26.9) Standard Remote Lamp Capability 7.2W No 7.2W Yes 7.2W Yes * AC Input figures in parenthesis are for NiCad battery models. Photometrics Dimensions 233/4” (9.5 cm) 3 3/4” Horizontal Isofootcandle Distribution 6 Volt, 7.2 Watt SBT Lamp 12 Volt, 7.2 Watt SBT Lamp (60.3 cm) 7 1/4” (18.4 cm) 51/4” (13.3 cm) 23 EXT Recessed Gimbal Emergency Light Features • Easy recessed installation in suspended ceilings • Built-in hanger bar • Compact, low-profile design • All metal housing and gimbal assembly • Ceiling white trim ring • Lamp adjusts in two planes to 26˚ • High-output, 8 watt halogen lamphead • Maintenance-free battery 8W • 120/277VAC operation standard • Fully automatic, solid-state charger • Low-voltage battery disconnect • Transformer isolation protection • Test switch and AC-On light • 90 minute operation • Temperature range: 20°C to 30°C (68°F to 86°F) • UL 924 Listed Ordering Information EXT-122-EM-K Aptions ccessories (Order Separately O (Add suffix to model) ) Accessories (Order Separately) WGLX Wire guard EXT-122-EM-K unit shown installed using built-in hanger bars Product Selector Guide Electrical Base Catalog Numbers Output Volts EXT-122-EM-K 6 Output Watts 1.5 2 3 Hours Hours Hours 8 — 4 Hours Standard Lamp Remote Capability — 8W Hal. No — Dimensions 6 1/8” (16.5 cm) Diameter 1 24 14” ( /2” 35.5 (62 7 1/2” .2 (19.0 cm) Photometrics Horizontal Isofootcandle Distribution (17 (m (m in.) ax .) 7” .7 6 Volt, 8 Watt Halogen SBT Lamp cm ) cm ) cm ) 1 /2” ) 10 .6 cm 8 1/2” (21.6 cm) 24 (26 Emergency Lighting Square Units Features Lite2 10W to 30W • 120/277VAC operation standard • Fully automatic, solid-state charger • Low-voltage battery disconnect • Transformer isolation protection • Test switch and AC-On light • Available with Spectron® self-testing/ self-diagnostic electronics with timedelay relay (TDR) standard • 90 minute operation • Temperature range: 20°C to 30°C (68°F to 86°F) • UL 924 Listed • Easy to install • Matte-white frame and satinblack housing • Available in single and twin lamp models • Maintenance-free battery • Prismatic lens for uniform illumination • Polished alzak reflector • Remote capability (ERS models only) • Matching remote fixtures Ordering Information Standard Models Spectron Self-Testing Models EDS ERS Single lamp unit ERS-2-2 Twin lamp unit ERS-3 Single lamp unit ptions (Add suffix to model) Single lamp unit O Options (Add EDS-2 Twin lamp unit ESS-I Single lamp unit ERS-I Single lamp unit ERS-3I Single lamp unit Accessories Accessories suffix to model) Voltmeter * Fully recessed option -V -FRM ESS-I-2 Twin lamp unit ERS-2I-2 Twin lamp unit F-SRM WG-MLT RERS-1-0609 RERS-2-0607 * Not available with fully recessed models. (Order Separately) (Order Separately) Semi-recessed mounting kit Wire guard Matching remote fixture - single lamp Matching remote fixture - twin lamps Product Selector Guide Electrical Catalog Numbers Output Watts Output 1.5 2 3 Volts Hours Hours Hours 4 Hours No. Lamps Standard Lamps Remote Capability EDS, ESS-I* 6 10 — — — 1 9W No ERS, ERS-I* 6 20 10 — — 1 9W Yes ERS-3, ERS-3I* 6 30 22 15 — 1 9W Yes EDS-2, ESS-I-2* 6 14.4 — — — 2 7.2W No ERS-2-2, ERS-2I-2* 6 30 22 15 — 2 7.2W Yes * Includes Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard Dimensions (Fully-Recessed) 4” (10.1 cm) Semi-recessed model 11 9/16” sq. (29.4 cm) (Semi-Recessed) (Surface Mounted) 4” 2 1/4” (10.1 cm) Fully-recessed model (5.7 cm) 9” sq. (22.9 cm) 9” sq. (22.9 cm) 25 Delite Emergency Lighting Cylinder Units Features 12W, 31W • Low-voltage battery disconnect • Transformer isolation protection • Test switch and AC-On light • 90 minute operation • Temperature range: 20°C to 30°C (68°F to 86°F) • UL 924 Listed • Easy to install • Attractive matte-white cylinders on contrasting black swivel • Brushed aluminum base plate • Multidirectional swivel lighting heads • Maintenance-free battery • Matching remote fixture • 120/277VAC operation standard • Fully automatic solid-state charger Ordering Information ESC2-0 Options (Add Accessories suffix to model) (Order Separately) Ceiling recess mounting kit Wire guard F-TMK 41G Product Selector Guide Base Catalog Numbers Output Volts ESC2-0 6 Electrical Output Watts 3 4 Hours Hours 1.5 2 Hours Hours 12 — — No. Cyls. Standard Lamp(s) Remote Capability 2 6W Halogen No — Dimensions C F A B D Photometrics Horizontal Isofootcandle Distribution 6 Volt, 6 Watt Halogen SBT Lamp 10 10 Feet Left Feet Left LAMP AXIS 0 IFC 0.5 0.3 26 IFC Feet Right Feet Right 10 LAMP AXIS 0 0.1 0.2 0 10 20 30 40 50 Feet From Lamp (measured on axis) 60 E Vertical Distribution Horizontal Distribution 70 10 Unit Model Number 0.5 ESC2-0 0.3 0.2 10” 0 10 20 A 0.1 Dimensions B C D 4 3/4” 10 1/2” 8 1/2” E F 5” 22” 25.4 cm 12.0 cm 26.7 cm 21.6 cm 12.7 cm 55.9 cm 30 40 50 60 70 Dotted lines show heads in maximum horizontal position. Feet From Lamp (measured on axis) Harsh Environment Emergency Lights Features • Gasketed construction • Low-voltage battery disconnect • Corrosion resistant hardware • Transformer isolation protection • Charcoal grey thermoplastic case • Test switch and AC-On light • Available in 6- or 12-volt versions • Maintenance-free battery • Available with Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard • Capacities up to 100W • 90 minute operation • Matching remote fixture • Temperature range: 10°C to 40°C (50°F to 104°F) • Fully adjustable lampheads • 120/277VAC operation standard • Fully automatic, solid-state charger • UL 924 Listed An • UL 924 Damp Location Listed Severe Conditions Product Line Ordering Information N4X2 N4X4 Options N4X7 (Add N4X7-12V N4X14 N4X14-12V (Order Separately) A (a) Supplied with mounting plate. Specify voltage and wattage when ordering. Example: GNXSB0618. See “Remote Heads and Fixtures” section for available lamps. (1) Not available on N4X2 model. Lamps With Optional Shatter Containment Feature Protective lamp cover safely contains glass lamp fragments in the event of accidental breakage in sensitive areas such as food preparation or hospitals. To order N4X unit with shatter containment option, suffix the catalog number. See “Remote Heads and Fixtures” section for available lamps (1). Example: N4X4-GNXSB0608-L. Optional Lamps To order two nonstandard lamps on the fixture, suffix catalog number. See “Remote Heads and Fixtures” section for available lamps. Example: N4X4-GNXSB0612. (1) Excludes 6V, 7.2W and 12V, 9W lamps. Product Selector Guide Damp(1) 40G Wire guard GNXSB Matching remote head - single (a) (a) ccessories (O rder Separately ) GNXDB Matching remote head - twin O Electrical Base Catalog Numbers N4X2 N4X4 N4X7 N4X7-12V N4X14 N4X14-12V Output Volts 1.5 Hours 6 6 6 12 6 12 15 31 50 50 100 100 Output Watts 2 3 Hours Hours — 22 36 36 79 79 — 15 29 29 61 61 4 Hours Standard Lamps Remote Capability — — 22 22 44 44 7.2W 7.2W 7.2W 9W 7.2W 9W No Yes Yes Yes Yes Yes Dimensions 5/8” Diam. Photometrics Horizontal Isofootcandle Distribution 6 Volt, 7.2 Watt SBT Lamp 12 3/4” (32.4 cm) 13 5/8” (34.6 cm) 16 1/4” (41.3 cm) Corrosive Accessories suffix to model) I Spectron self-testing/self-diagnostic electronics -0 Unit supplied without lighting heads (1) (1) (Add to head model ) -1 ptions Unit supplied withsuffix one lighting -A31 Auxiliary 3-conductor AC line cord (120V) -A32 Auxiliary 3-conductor AC line cord (277V) N4X 15W to 100W 6” 10 1/4” 12 Volt, 9 Watt SBT Lamp 4 7/8” 11” Max. 27 AS Industrial Emergency Lights Features • Easy to install • NEMA 1 steel cabinet with dark brown enamel finish • 1/2” and 3/4” wiring KOs provided • Wet-cell and maintenance-free battery models • 6-, 12- and 24-volt models • 12- and 24-volt models allow longer wiring runs • Glare-free lampheads • Available with third lamphead • Available without lampheads • Matching remote fixtures 75W to 360W • 120/277VAC operation standard • Fully automatic, solid-state charger • Low-voltage battery disconnect • Transformer isolation protection • Test switch and AC-On light • Available with Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard • 90 minute operation • Temperature range: 20°C to 30°C (68°F to 86°F) • UL 924 Listed Ordering Information See Product Selector Guide for available models SRH Series Matching Remote Lighting Head Options I -V -C -0 -1 -2 -3 -A31 -A32 (Add Accessories suffix to model) Spectron self-testing/self-diagnostic electronics Voltmeter Ammeter (1) Unit supplied without lampheads Unit supplied with one lamphead Unit supplied with two lampheads (2) Unit supplied with three lampheads Auxiliary 3-conductor AC line cord (120V) Auxiliary 3-conductor AC line cord (277V) (1) Not available with all models. Consult factory. (2) Available for use with 12EDC and 12EDN models only. All other models are supplied standard with two lampheads. Photometrics (1) WB-6 6000 L-6 L-12-S 40G 41G SRHSB SRHDB (Order Separately) Wall mounting hanger bracket (all models) Heavy-duty mounting shelf (Enclosure 1 models) Mounting shelf (Enclosure 1 models) Mounting shelf (Enclosure 2 models) Wire guard (Enclosure 1 models) Wire guard (Enclosure 2 models) Matching remote lighting head - single * Matching remote lighting head - twin * * Supplied with round mounting plate. Specify voltage and wattage when ordering. Example: SRHSB0612. See “Remote Heads and Fixtures” section for available lamps. Optional Lamps To order two nonstandard lamps on the fixture, suffix catalog number. See “Remote Heads and Fixtures” section for available lamps. Example: AS130-SRHSB0612. Dimensions Horizontal Isofootcandle Distribution 6 Volt, 7.2 Watt SBT Lamp 12 Volt, 7.2 Watt SBT Lamp D C 6 Volt, 25 Watt SB Lamp 24Volt, 7.2Watt SB Lamp B A Enclosure Enclosure Style Ga. A B 14” 8” 111/2” 18 3/4” 8” 111/2” 18 3/4” 1 20 Ga. (.036”) 35.5 cm 16” 2 20 Ga. (.036”) 40.6 cm 28 C D 20.3 cm 29.2 cm 47.6 cm 20.3 cm 29.2 cm 47.6 cm AS Product Selector Guide Maintenance-Free Battery Models Base Catalog Numbers Electrical Enclosure Style Output Volts AS80 1 6 80 62 AS130 1 6 130 AS180-12V 1 12 AS270-12V 1 AS360-12V 1.5 Hours Output Watts 2 3 Hours Hours 4 Hours Standard Lamp Remote Capability 43 33 7.2W Yes 101 70 54 7.2W Yes 180 144 112 77 7.2W Yes 12 270 227 168 116 7.2W Yes 1 12 360 288 230 172 7.2W Yes AS180-24V 1 24 180 144 112 77 9.0W Yes AS270-24V 1 24 270 227 168 116 9.0W Yes AS360-24V 1 24 360 288 230 172 9.0W Yes 4 Hours Standard Lamp Remote Capability NOTE: Batteries for all Maintenance-Free models are shipped with the units. Wet-Cell Lead-Calcium Battery Models Base Catalog Numbers Electrical Enclosure Style Output Volts ALC-X-30 1 6 78 57 42 28 25W Yes ALC-X-60 1 6 144 108 81 54 25W Yes ALC-X-100 1 6 162 121 91 61 25W Yes 12EDC-X-36S 2 12 200 165 125 86 (*) Yes 12EDC-X-60S 2 12 240 192 153 115 (*) Yes 12EDC-X-120S 2 12 350 280 224 168 (*) Yes 4 Hours Standard Lamp Remote Capability 1.5 Hours Output Watts 2 3 Hours Hours (*) These models supplied standard without lampheads NOTE: Batteries for all Wet-Cell Lead-Calcium models are shipped separately. Wet-Cell Nickel-Cadmium Battery Models Base Catalog Numbers Electrical Enclosure Style Output Volts AS75 1 6 75 57 42 28 25W Yes AS145 1 6 110 85 59 46 25W Yes AS210 1 6 145 112 84 54 25W Yes 12EDN-10S 2 12 48 38 25 20 (*) Yes 12EDN-18S 2 12 100 76 54 44 (*) Yes 12EDN-30S 2 12 150 115 86 57 (*) Yes 1.5 Hours Output Watts 2 3 Hours Hours (*) These models supplied standard without lampheads NOTE: Batteries for all Wet-Cell Nickel-Cadmium models are shipped separately. 29 IPS Wet Location Emergency Lights Features • Suitable for wet or damp applications • Designed for Class I, Div 2 locations • Compact, factory assembled system • Sealed and gasketed NEMA 3R construction • Corrosion resistant hardware • Black thermoplastic case with battery vent • Available in 6- or 12-volt versions • Fully adjustable 8 watt halogen sealed beam lampheads • Maintenance-free battery • Matching remote fixtures An Severe Conditions Product Line 36W, 72W • 120/220/240/277VAC operation standard • Fully automatic, solid-state charger • Automatic 15-minute retransfer delay • Low-voltage battery disconnect • Transformer isolation protection • Test switch and AC-On light • T-6 100°C (212°F) lamphead rating • 120 minute operation • Temperature range: 0°C to 40°C (32°F to 104°F) • UL Listed to Standard 924 and Standard 844 (Hazardous Locations) Ordering Information 844 NEMA 3R Enclosures (NEMA Standards 250) Hazardous Damp Corrosive Wet Enclosures are intended for outdoor use primarily to provide a degree of protection against falling rain and sleet, undamaged by the formation of ice on the enclosure. Ordering Information Options (Add suffixC1D2-12V36 to model) C1D2-12V72 Accessories C1D2-6V36 C1D2-6V72 (Order Separately) Options -0 -1 -12 (Add suffix to model) Unit supplied without lampheads Unit supplied with one lamphead Unit supplied with 12 watt halogen lamps Product Selector Guide Base Catalog Numbers C1D2-6V36 C1D2-6V72 C1D2-12V36 C1D2-12V72 Electrical Output Volts 2 Hours 6 6 12 12 36 72 36 72 Output Watts 3 Hours 24 50 24 50 Photometrics Horizontal Isofootcandle Dist. 6 Volt, 8 Watt Halogen SB Lamp Photometrics measured by independent testing laboratory 30 12 Volt, 8 Watt Halogen SB Lamp 4 Hours Standard Lamps Remote Capability 19 39 19 39 8W Hal. 8W Hal. 8W Hal. 8W Hal. Yes Yes Yes Yes Accessories IPS (Order Separately) Remote Lighting Heads Lamp Volts Watts Matching single and twin head remote lighting fixtures Single-Head Model Numbers Hub Left Side Hub Right Side Hub Both Sides 6 8 C1D2R-6V8W C1D2R-6V8WR C1D2R-6V8WF 6 12 C1D2R-6V12W C1D2R-6V12WR C1D2R-6V12WF 12 8 C1D2R-12V8W C1D2R-12V8WR C1D2R-12V8WF 12 12 C1D2R-12V12W C1D2R-12V12WR C1D2R-12V12WF Lamps Volts Watts Twin-Head Model Numbers Hub Left Side Hub Right Side Hub Both Sides 6 8 C1D2TR-6V8W C1D2TR-6V8WR C1D2TR-6V8WF 6 12 C1D2TR-6V12W C1D2TR-6V12WR C1D2TR-6V12WF 12 8 C1D2TR-12V8W C1D2TR-12V8WR C1D2TR-12V8WF 12 12 C1D2TR-12V12W C1D2TR-12V12WR C1D2TR-12V12WF * PAR 36 Halogen sealed beam lamps. Dimensions 11/2” (3.8 cm) 1.9 cm 17” (43.1 cm) 12 1/2” (31.7 cm) 11 1/4” (28.6 cm) 12” (30.5 cm) 6 3/4” (17.1 cm) 13 1/4” (33.7 cm) 95/8” 9 5/8” (24.4 cm) Mounting holes 41/4” 7 227//88”” (7.3 cm) 7711//22” (1981cm) /8” 8 1/8” (20.6 cm) 3 /4” Hub 1.9 cm 4 1/4” (10.8 cm) 1111//44”” (3.25 cm) 4 /8” 5 4 /8” (14.3 cm) Mounting holes 7 2 7/8” 2 /8” (7.3 cm) 3 /4” Hub 1.9 cm 12” 12” (30.5 cm) 125/8” 12 5/8” (32.1 cm) 31 XPB Explosion-Proof Emergency Lights Features • Suitable for Class I, Div. I & II applications • High-strength, copper-free aluminum housing • Quick access thread-on cover • Test switch included • AC-On indicator light • Maintenance-free battery • 6- and 12-volt models An Corrosive Severe Conditions Product Line 75W • Capacity for remote fixtures • 120/277VAC operation standard • Fully automatic, solid-state charger • Low-voltage battery disconnect • Transformer isolation protection • Optional fixtures available for a wide range of hazardous environments • 90 minute operation • Temperature range: 20°C to 30°C (68°F to 86°F) • UL Listed to Standard 924 and Standard 844 (Hazardous Locations) Ordering Information Ordering Information (Class I, Divisions I & II, Groups C through G) Explosion-Proof XPB-75P 12XPB-75P Options -TDR (Add Accessories suffix to model) (Order Separately) 15-minute retransfer delay (120VAC only) Product Selector Guide Electrical Base Output Watts Output 1.5 2 3 4 Catalog Numbers Volts Hours Hours Hours Hours XPB-75P 12XPB-75P Standard Lamp Remote Capability 6 75 57 42 28 (*) Yes 12 75 57 42 28 (*) Yes (*) Unit is supplied without lighting fixtures. Unit must operate at least one lighting fixture (unit mounted or remote) to meet UL Standard 924 requirements. See following page for explosion-proof lighting fixtures and accessories. Dimensions 10 3/4” 12” (27.3 cm) 6 3/16” (30.5 cm) (15.7 cm) XPB-75P shown with EX-1CD unit-mounted lighting fixtures 14 1/2” (36.8 cm) Depth = 8” (20.3 cm) 32 3” (7.6 cm) Depth = 5 9/16” (14.1 cm) Explosion-Proof Fixtures (1) Fixtures for direct mounting to XPB Series Unit EX-1CD All fittings required for unit mounting supplied standard. Up to three fixtures may be connected (unit mounted and/or remote). Catalog Number EX-1CD618 EX-1CD628 EX-1CD Lamp Lamp Voltage Wattage 6 6 18 28 Catalog Number EX-1CD1218 EX-1CD1228 Lamp Lamp Voltage Wattage 12 12 18 28 Fixtures for remote mounting REX1CDP* Fixture for pendant mounting; one 1/2” hub, rigid or flexible mounting. Catalog Number REX1CDP Lamp Lamp Voltage Wattage Catalog Number Lamp Lamp Voltage Wattage REX1CDP618 6 18 REX1CDP1218 12 18 REX1CDP628 6 28 REX1CDP1228 12 28 REX1CDC* Fixture for ceiling mounting; four 1/2” hubs, three close-up plugs. Catalog Number REX1CDC Lamp Lamp Voltage Wattage Catalog Number Lamp Lamp Voltage Wattage REX1CDC618 6 18 REX1CDC1218 12 18 REX1CDC628 6 28 REX1CDC1228 12 28 REX1CDW* Fixture for wall mounting; four 1/2” hubs, three close-up plugs. Catalog Number REX1CDW Lamp Lamp Voltage Wattage Catalog Number Lamp Lamp Voltage Wattage REX1CDW618 6 18 REX1CDW1218 12 18 REX1CDW628 6 28 REX1CDW1228 12 28 REX1CDA* Fixture for angled (15°) wall mounting; two 1/2” hubs, one close-up plug. Catalog Number REX1CDA Fixture Accessories XWG XWG EX100CD REX-SDR REX-AR REX1CDA618 REX1CDA628 Lamp Lamp Voltage Wattage 6 6 18 28 Catalog Number REX1CDA1218 REX1CDA1228 Lamp Lamp Voltage Wattage 12 18 12 28 * Fixtures shown with optional “XWG” globe guards. (1) When connected to XPB emergency units, lighting fixtures will operate in the “normally-off” mode. EX100CD REX-SDR REX-AR Aluminum (copper-free) globe guard. Protects fixture lens from accidental impact damage. Two-coat, baked epoxy, medium-gray enamel finish. Auxiliary housing with “EXIT” legend for “normally off” operation only. Housing constructed of 18-gauge sheet metal; medium-gray enamel finish. Glass face with 6” high, 3/4” stroke red letters on white background. (Lighting fixture not included). Standard dome reflector. Steel, with white porcelain enamel finish. Angled (30°) reflector. Steel, with white porcelain enamel finish. 33 Lampak Fluorescent Power Packs Features UFO-3, 4, 5, 6 W NE An Severe Conditions Product Line Damp • Battery case made of heavy 22gauge steel • Reliable, high-frequency inverter • Sealed nickel-cadmium battery • Universal 120/277VAC operation • Test switch and LED charge indicator light supplied standard • Provides 90 minutes of emergency lighting • Low power consumption • Temperature range: 0°C to 50°C (32°F to 122°F) • UL 924 Listed (Emergency Lighting) • UL 924 Damp Location Listed • Compatible with electronic, standard magnetic, energy saving, and dimming AC ballasts • Compatible with most standard T8, T10 or T12, energy-saving or rapid start, (4-pin) long compact fluorescent lamp • Easy installation with versatile mounting capability inside of ballast channel, on top of or remote from fixture • Operates one or two lamps in emergency mode • Can be used with switched or unswitched lighting fixtures Ordering Information Standard Models UFO-3AW, UFO-4W, UFO-5W, UFO-5AW, UFO-6W Self-Testing Spectron Model UFO-6WI ptions (Add suffix to model) O Accessories (Order Separately) F-WC Wire bundle cover (1) SPRTS Remote test switch/charge indicator ccessories (Order Separately) module (2) A (1) Encloses exposed wiring harness when power pack is externally mounted on the lighting fixture. One required per fixture. Extended Temperature Model* UFO-6W-CLD (2) Fits single-gang box. * Extends temperature range to -20°C to 55°C (-4°F to 131°F) Product Selector Guide Catalog Number Output Wattage Initial Lumens Electrical Number of Lamps Operated UFO-3AW UFO-4W UFO-5W UFO-5AW UFO-6W, UFO-6WI UFO-6W-CLD 9.6 14.4 14.4 14.4 24.0 24.0 350-450 500-600 600-700 600-700 1100-1400 Up to 1200 1 1 1 1 or 2 1 or 2 1 or 2 Base Lamp Sizes Input Wattage 2’-4’ 2’-4’ 2’-8’ 2’-8’ 2’-8’ 2’-8’ 3.5 3.5 3.5 3.5 4.0 4.0 Installation Lampak UFO 3, 4, 5 and 6 emergency power packs do not affect normal fixture operation and may be used with either switched or unswitched fixtures. UFO-3, 4, 5 and 6 packs may be installed inside, on top of, or remote from the fixture. The fluorescent pack may be remotely installed up to half the distance from the lamp the AC ballast manufacturer recommends, or up to 50 feet, whichever is less. UFO-3, 4, 5 and 6 packs are not suitable for installation in heated air outlet fixtures and wet or hazardous location fixtures. Installation is not recommended with fixtures where the ambient temperature may fall below 0°C (32°F ). Dimensions B A C Model 34 A B C UFO-3AW, 4W, 5W, 5AW 9 3/8” (23.8 cm) 11/2” (3.8 cm) 2 3/8” (6.0 cm) UFO-6W, -6WI & -6-CLD 13 3/8” (33.9 cm) 1 1/2” (3.8 cm) 2 3/8” (6.0 cm) Lampak High Lumen Fluorescent Power Packs Features • Standard and Spectron self-testing/ self-diagnostic models offered. • Compatible with electronic, standard magnetic, energy saving, and dimming AC ballasts • Compatible with most standard 2 - 8 foot, T8, T9, T10 or T12 and rapid-start (4-pin) long compact fluorescent lamps • Easy installation on top of or remote from fixture • Operates one or two lamps depending on fixture • Can be used with switched or unswitched lighting fixtures UFO-7 • Battery case made of 22-gauge steel • Reliable, high-frequency inverter • Premium sealed nickel-cadmium battery • Universal 120/277VAC operation • Test switch and LED charge indicator light supplied standard • 90 minutes emergency operation • Low power consumption • Temperature range: 0°C to 40°C (32°F to 104°F) • UL 924 Listed (Emergency Lighting) • UFO-7WI Model UL 924 Damp Location Listed W NE An Severe Conditions Product Line Ordering Information UFO-7W (Standard Model) UFO-7WI (Self-Testing Model) Options (Add Damp * UFO-7WI Model Only Accessories (Order Separately) F-WC Wire bundle cover (1) SPRTS Remote test switch/charge indicator ccessories (Order Separately) module (2) A suffix to model) (1) Encloses exposed wiring harness when power pack is externally mounted on the lighting fixture. One required per fixture. (2) Fits single-gang box. Product Selector Guide Catalog Number UFO-7W UFO-7WI Base Output Wattage Initial Lumens Electrical Number of Lamps Operated Lamp Sizes Input Wattage 57.6 57.6 1450-3500 1800-3500 1 or 2 1 or 2 2’-8’ 2’-8’ 8.0 8.0 Table 1 (Models UFO-7W, UFO-7WI)* Lamp Base Type Diameter Power (Length) No. of Lamps Operated (Emerg.) Single or Bipin 4-Pin (2G11) 17 - 40W (2’ to 4’) 40 - 215W (5’ to 8’) 18 - 39W 40 - 55W 1 or 2 1 1 or 2 1 4-Pin (G24q, GX24q) 18 - 42W 1 or 2 (1”, 11/8”,11/4”,11/2”) T8, T9, T10, T12 Long Compact Compact * Partial listing of lamps operated Table 2* Lamp Type FO25, FBO24 T8 FO32, FBO31 T8 FO40 T8 FO96 T8 F40 T12, F40/U F40 T12ES (34W) F48 T12/HO F96 T12 F96 T12/HO F96 T12/VHO Lumens 1 Lamp 2 Lamps 2250 2600 3000 3000 2400 -3000 -3000 3000 2700 2700 3000 -2800 -2900 -3300 -- Table 2* (Continued) Lamp Type PL-L 24W, F27/24BX Dulux L 27W PL-L 36W, F39/36BX Dulux L 39W PL-T 42W/4P PL-L 40W, F40/30BX F50BX, Dulux L 55W F28 2D/4P F38 2D/4P Lumens 1 Lamp 2 Lamps 1800 2300 2900 3500 3200 1800 3500 -- 2050 1450 2800 2800 Installation LAMPAK UFO-7W Series emergency power packs do not affect normal fixture operation and may be used with either switched or unswitched fixtures. UFO-7W Series models may be installed on top of, or remote from the fixture. The emergency ballast may be remotely installed up to half the distance from the lamp the AC ballast manufacturer recommends, or up to 50 feet, whichever is less. UFO-7W Series emergency power packs are not suitable for installation in heated air outlet fixtures and wet or hazardous location fixtures. Installation is not recommended with fixtures where the ambient temperature may fall below 0°C (32°F ). Dimensions 16.3” 1.7” 41.4cm 4.4cm 5.5” 13.8cm * Partial listing of lamps operated. Initial lumen output measured at 25°C ambient temperature. 35 Lampak Compact Fluorescent Power Packs Features UFO-12 W NE An Severe Conditions Product Line Damp • Compatible with electronic, standard magnetic, energy saving, and dimming AC ballasts • Compatible with most 13W to 42W rapid start, 4-pin compact twin, quad or triple twin tube fluorescent lamps • Easy installation on top of or remote from fixture • Operates one or two lamps in emergency mode • Can be used with switched or unswitched lighting fixtures • Battery case made of heavy 22gauge steel • Reliable, high-frequency inverter • Premium sealed nickel-cadmium battery • Universal 120/277VAC operation • Test switch and LED charge indicator light supplied standard • 90 minute operation • Low power consumption • Temperature range: 0°C to 50°C (32°F to 122°F) • UL 924 Listed (Emergency Lighting) • UL 924 Damp Location Listed Ordering Information UFO-12W Accessories Options (Add (Order Separately) F-WC Wire bundle cover (1) SPRTS Remote test switch/charge indicator module (2) ccessories rder eparately ) (1) Encloses exposed wiring harness(O when power S pack is externally A suffix to model) mounted on the lighting fixture. One required per fixture. (2) Fits single-gang box. Product Selector Guide Electrical Base Catalog Number UFO-12W Ballast Compat. Number Initial of Lamps Lumens Operated Magnetic, See See Electronic, Table 1 Table 1 Energy Saving & Dimming Lamp Type 13W through 42W quad and triple tube lamps without G24q-2, G24q-3 integral starters (4-pin lamps) GX24q-3, GX24q-2 Table 1* Lamp Type (4-Pin) PL-T 42W/4P, Dulux T/E 42W PL-T 32W/4P, Dulux T/E 32W PL-T 26W/4P, Dulux T/E 26W, F26TBX/4P PL-T 18W/4P, Dulux T/E 18W, F18TBX/4P PL-C 26W/4P, Dulux D/E 26W, F26DBX/4P PL-C 18W/4P, Dulux D/E 18W, F18DBX/4P PL-C 13W/4P, Dulux D/E 13W, F13DBX/4P PL-L 40W, Dulux L 40W, F40/30 BX/4P PL-L 36W, Dulux L 39W, F39/36 BX/4P PL-L 24W, Dulux L 27W, F27/24 BX/4P PL-L 18W, Dulux L 18W, F18 BX F3 82D/4P FO25, FBO24 T8 FQL 28 FO17, FBO16 T8 Base Types Lumens 1 Lamp 2 Lamps 750 -575 750 450 725 300 525 600 700 475 575 350 425 650 -575 750 475 550 300 400 525 650 525 700 600 700 425 500 Input Wattage 3.5 Application LAMPAK Series UFO-12W emergency power pack does not affect normal fixture operation and may be used with either a switched or unswitched fixture. The UFO12W may be installed on top of, or remote from the fixture. The emergency ballast may be remotely installed up to half the distance from the lamp the AC ballast manufacturer recommends, or up to 50 feet, whichever is less. UFO-12W emergency power packs are not suitable for installation in heated air outlet fixtures and wet or hazardous location fixtures. Installation is not recommended with fixtures where the ambient temperature may fall below 0°C (32°F ). Dimensions * Partial listing of lamps operated Initial lumen output measured at 25°C ambient temperature. 1.5” 3.8cm 9.4” 23.8cm 2.4” 6.0cm 36 Lampak Low-Profile Fluorescent Power Packs Features • Low profile design • Compatible with electronic (including those containing end-of-life shutdown circuits), standard magnetic, energy saving, and dimming AC ballasts • Compatible with most standard and HO T5 miniature bipin, T8 bipin and rapid-start (4-pin) long compact lamps • Easy ballast channel installation • Operates one lamp • Can be used with switched or unswitched lighting fixtures UFO-LP • Compact battery case • Reliable, high-frequency inverter • Premium sealed nickel-cadmium battery • Universal 120/277VAC operation • Test switch and LED charge indicator light supplied standard • Provides 90 minutes of emergency lighting • Low power consumption • Temperature range: 0°C to 50°C (32°F to 122°F) • UL 924 Listed (Emergency Lighting) W NE Ordering Information UFO-LP1 (Standard Output Model) UFO-LP2 (High Output Model) Options (Add Accessories (Order Separately) SPRTS Remote test switch/charge indicator module (1) (1) Fits single-gang box. ccessories (Order Separately) A suffix to model) Product Selector Guide Electrical Base Catalog Number Lumen Output Number of Lamps Operated UFO-LP1 UFO-LP2 See Table 1 See table 2 1 1 Lamp Type Lumens 700 FP54, F54 T5/HO FP39, F39 T5/HO 620 FP24, F24 T5/HO 390 FP28, F28 T5 700 FP21, F21 T5 620 FP14, F14 T5 430 F32 T8 (4’) 635 F40 T8 (5’) 570 F48 T8/HO (4’) (44W) 470 PL-L 50W, F50BX/RS, Dulux L 55W 510 PL-L 40W, F40/30BX, Dulux L 55W 625 PL-L 36W, F39/36BX, Dulux L 55W 610 T5 HO, T5, T8 HO, T8, 4-pin Compact T5 HO, T5, T8 HO, T8, 4-pin Compact Input Wattage 3.2 3.0 Table 2 (UFO-LP2)* Table 1 (UFO-LP1)* Lamp Types * Partial listing of lamps operated. Initial lumen output measured at 25°C ambient temperature. Lamp Type Lumens 1250 FP54, F54 T5/HO FP39, F39 T5/HO 1125 FP24, F24 T5/HO 725 FP28, F28 T5 1325 FP21, F21 T5 1025 FP14, F14 T5 750 F17 T8 650 F25 T8 750 F32 T8 (4’) 1100 F40 T8 (5’) 1325 F48 T8/HO (4’) (44W) 1100 F60 T8/HO (5’) (55W) 1275 PL-L 50W, F50BX/RS, FT55DL 1050 PL-L 40W/RS, F40/30BX, FT40DL/RS 925 PL-L 36W, F39/36BX, FT36DL 900 Dimensions 1.18” (3.0cm) Application Dual-Lite Lampak UFO-LP Series low-profile fluorescent emergency ballasts work in conjunction with a low-profile or standard-size electronic AC ballast containing an end-of-life shut down circuit to convert new or existing standard or high output T5 fluorescent fixtures into unobtrusive emergency lighting. Model UFO-LP1 can be used with one 14 - 28W standard or 24 - 54W high output T5; one 32W (4’), 40W (5’) and 44W H0 (4’) T8 fluorescent lamp; or one 36 - 55W (4-pin) long compact fluorescent lamp (see Table 1). Model UFOLP2 can be used with one 14 - 54W (2’ - 4’) standard or high output T5, 17 -55W (2’ - 5’) standard or high output T8, 36 - 55W (4-pin) long compact fluorescent lamp (see Table 2). UFO-LP Series models are also compatible with most 1, 2, 3, and 4-lamp electronic (including those containing end-of-life shutdown circuits), standard, energy saving, and dimming AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. UFO-LP Series models are suitable for use in indoordry locations except air handling heated air outlet fixtures, and wet, damp, or hazardous location fixtures. For information about specific lamp and ballast compatibility, please contact the factory. UFO-LP1 = 18.5” (41.4cm) UFO-LP2 = 21.5” (54.6cm) 1.18” (3.0cm) 37 Lampak HID Backup Ballast Features UFO-MH W NE An Severe Conditions Product Line Damp • Catches and maintains the arc of metal halide HID lamps • Provides two minutes of continuous arc maintenance • Maintains lamp at 20-30% normal operating power • Multiple catches from one recharging • Works with standard constant wattage autotransformer (CWA) magnetic ballasts • Compatible with most standard 150 to 400 watt probe-start metal halide M57, M58 and M59 HID lamps • Easy remote installation • Battery case made of heavy 22gauge steel • Reliable, high-frequency inverter • Premium sealed nickel-cadmium battery • Universal 120/277VAC operation • LED charge indicator light • Low power consumption • Temperature range: 0°C to 55°C (32°F to 131°F) • UL 924 Listed (Auxiliary Lighting) • UL Damp Location Listed Ordering Information UFO-MH175 UFO-MH250 UFO-MH400 Options (Add suffix to model) Product Selector Guide Base Catalog Number Maximum Distance From Lamp Maintenance Period UFO-MH175 UFO-MH250 UFO-MH400 30 Feet 50 Feet 80 Feet 2 Minutes 2 Minutes 2 Minutes Arc Accessories (Order Separately) Electrical Lamp Types Operated 175W or 150W energy saving MH (M57) 250W or 225W energy saving MH (M58) 400W or 360W energy saving MH (M59) Input Wattage 6W @ 120VAC 6W @ 120VAC 10W @ 277VAC 10W @ 277VAC Application The Dual-Lite Lampak UFO-MH Series devices are battery-operated backup ballasts that catch and maintain the arc of one metal halide HID lamp during AC power sags, interruptions or failures. The UFO-MH Series device works in conjunction with standard constant wattage autotransformer (CWA) magnetic ballasts. The UFO-MH device detects AC power line disturbances and operates the HID lamp with sufficient power to keep the lamp arc from extinguishing during power line disturbances. The lamp arc, in a typical HID lamp, will extinguish if an AC power failure persists for more than four milliseconds. The UFO-MH unit detects AC power line disturbances, then supplies supplemental power to the lamp within approximately two milliseconds, thereby maintaining the lamp arc. The UFO-MH Series is suitable for damp location use. It is also for use with listed indoor fixtures EXCEPT air handling heated air outlets and wet or hazardous location fixtures. The UFO-MH Series may be used with an auxiliary generator or inverter power system and the unit’s two-minute time limit allows more than ample time for an auxiliary generator to pick up and support the metal halide lamp for emergency lighting purposes. 38 Dimensions 12.25” 31.1cm 1.75” 4.4cm 7.25” 18.4cm Exit Signs LX Series DK Series LT Series NYXC Series SMC Series Sempra Series Sempra MR Sempra SC Sempra SCWL Sempra SERS NYDC Series LN4X Series Freedom LED LEDS Series NYX Series CMX Series LE Series LES Series NYE Series NYES Series DEX Series Designer LED Exit Signs...................................................................40 AC Incandescent Exit Signs..............................................................41 Designer Tandem Units. .................................................. 42, 43 New York Tandem Units......................................................... 44 Tandem Units with Side Mounted Heads. ................................ 45 Diecast LED Exit Signs.................................................................... 47 Master/Remote Diecast LED Exit Signs.................................... 48, 49 Severe Conditions Diecast LED Exit Signs............................... 50, 51 Wet Location Diecast LED Exit Signs...............................................52 Recessed Diecast LED Exit Signs......................................................53 New York Diecast LED Exit Signs.....................................................54 Wet Location LED Exit Signs.................................................... 55 Aluminum LED Exit Signs.................................................................56 Low-Profile Aluminum LED Exit Signs...................................... 57 New York LED Exit Signs......................................................... 58 Chicago Exit Signs.................................................................. 59 Recessed Mounting Edge-Lit LED Exit Signs........................... 60, 61 Surface Mounting AC Edge-Lit LED Exit Signs....................... 62, 63 New York Recess Mounted Edge-Lit LED Exit Signs.......................64 New York Surface Mounted Edge-Lit LED Exit Signs.....................65 Special Wording Incandescent Exit Signs.................................. 66 39 LX Designer LED Exit Signs Features All Models • UV-stable thermoplastic housing • Compact, low-profile design • Easy to install • Long-life LED lamps • Bright, even illumination • Red and green letters • Universal single/double face • White and black models offered • Push-in wiring connectors • Universal end/ceiling/wall mount • Universal snap-in, chevron arrows An Damp Severe Conditions Product Line Ordering Information LX U R W • Damp location listed • 120/277VAC, 60 Hz operation Emergency Models • Solid-state charger with low voltage disconnect • Maintenance-free NiCad battery • 2 hour emergency operation • Test switch and AC-On light • Available with Spectron® self-testing/self-diagnostic electronics with time-delay relay (TDR) standard • Temperature range: 10°C to 40°C (50°F to 104°F) • UL 924 Listed E -FAP Series Options Operation Faces Blank - AC Only E - Emergency U - Universal Single/Double Face Letter Color Also available in black finish Housing Finish R - Red G - Green W - White B - Black Options I -2C -FAP -FM -AF -DC -24K -SA (Add suffix to model) Spectron self-testing/self-diagnostic electronics 2-circuit operation (2)(6) Fire alarm panel interface (3)(5)(6) Flasher module (1)(5) Audible/Flasher module (1)(5) Remote DC operation (2)(4)(5) 220-240VAC, 60 Hz. operation “SALIDA” stencil face (1) (2) (3) (4) For specification with emergency models only. For use with AC models only. Operates with 24-volt AC or DC fire alarm panels. For emergency illumination of sign from remote 6-24 VDC power sources. (5) -FAP, -FM, -AF or -DC options may not be specified together. (6) -2C and -FAP options may be specified together. Power Consumption 40 120VAC 277VAC Red AC Only Models 2.6 watts 2.6 watts Green AC Only Models 2.1 watts 2.1 watts Red Emergency Models 3.8 watts 3.8 watts Green Emergency Models Power factor, average: .8 (lagging) 3.5 watts 3.5 watts Accessories FX2-E FX-E PMLXW PMLXB WGLX WG-MLT WGLXC WGLXE VRS3 (Order Separately) Emergency operation conversion module (red) Emergency operation conversion module (green) 121/2” Pendant mounting kit (white) 121/2” Pendant mounting kit (black) Wire guard (Wall mount) Wire guard (Wall mount) Wire guard (Ceiling mount) Wire guard (End mount) Vandal resistant shield Dimensions DK Incandescent Exit Sign Features • High impact thermoplastic housing with steel faceplate • Universal directional chevron arrow knockouts • Tamper resistant screws supplied • AC illumination provided by two 145V, 15T6 incandescent lamps • May be wall, ceiling or end mounted • Universal single/double face • White finish • Red letter models • 120V standard • Suitable for damp locations • Temperature range: 20°C to 30°C (68°F to 86°F) • UL 924 Listed An Severe Conditions Product Line Damp Ordering Information Model Number Description DKURW DKURWE 120V, AC-Only, single or twin face – universal mount, white finish 120/277V, emergency, single or twin face – universal mount, white finish Options (Add Accessories suffix to model) PMEXW WG-MLT WGLXC VRS3 (Order Separately) 12” pendant stem and canopy kit – white Wire guard (wall mount) Wire guard (ceiling or end mount) Vandal resistant shield Emergency model with power pack Dimensions 11” (27.9 cm) 5” (12.7 cm) CANOPY 1 /2” (1.3 cm) Power Pack 4 3/4” (12.0 cm) 11” (27.9 cm) 21/2” 1 /2” (1.3 cm) 8” (6.4 cm) (20.4 cm) 7 1/2” (19.1 cm) 31/4” (8.3 cm) (DKURWE model) 51/2” (14.0 cm) 111/4”(28.6 cm) with power pack 3 2 /8” (6.0 cm) 1 11 /2” (29.2 cm) 41 LT Designer Tandem Units Features • Factory assembled emergency unit/LED exit sign • UV-stable thermoplastic housing • Eyeball style lighting heads • High-output halogen lamps • White or black finishes offered • Remote capacity and damp location listed models available • 120/277VAC, 60 Hz operation • Solid-state charger • Maintenance-free battery • Low-voltage disconnect • Test switch and AC-On light • Available with Spectron® self-testing/self-diagnostic An Damp Severe Conditions Product Line electronics with time-delay relay (TDR) standard • Long-life LED lamps • Bright, even illumination • Universal single/double face • Red and green letter models • Snap-in, chevron arrows • Ceiling or wall mount models standard. Optional side mounting requires accessory kit • Temperature range: 20°C to 30°C (68°F to 86°F) (Damp location models: 10°C to 40°C (50°F to 104°F) • UL 924 Listed Ordering Information LT U R B D -AF Series Options Application Faces Blank - Standard model - Remote capacity model 3 - Damp location model D U - Universal Single/Double Face Letter Color Housing Finish R - Red G - Green Also available in black finish W - White B - Black Options (Add suffix to model) Accessories (Order Separately) Power Consumption 120VAC 277VAC Red Emergency Models 5.0 watts 5.0 watts Green Emergency Models 5.0 watts 5.0 watts Dimensions 3 5/8" (9.2 cm) Power factor, average: .8 (lagging) Photometrics High-Output Halogen Lamp Horizontal Isofootcandle Distribution 5W MR-16 Lamp • Standard Lamp for LT unit • 5W Lamp for LZR Remote Fixtures 10W MR-16 Lamp • 10W Lamp for LZR Remote Fixtures 14 1/4" (36.2 cm) 17/8" (4.7 5 cm) 13" (33 cm) 42 LT Product Selector Guide Remote Damp Colors Standard Capacity Location Exit Stencil Models Models(1) Models Letters Housing Face(s) Description LTURW LTURW3 LTURWD Red White White Single/double face tandem unit LTURB LTURB3 LTURBD Red Black Black Single/double face tandem unit LTUGW LTUGW3 LTUGWD Green White White Single/double face tandem unit LTUGB LTUGB3 LTUGBD Green Black Black Single/double face tandem unit (1) Operates the integral unit heads plus one additional 5 watt lighting fixture or exit sign. Options (Add Accessories suffix to model) I -0 -FAP Spectron self-testing/self-diagnostic electronics (4) Unit supplied without lighting heads (3) Fire alarm panel interface (1)(2) -FM -AF -24K -SA Flasher module (2) Audible/Flasher module (2) 220-240VAC, 60 Hz operation “SALIDA” stencil face (1) Operates with 24-volt AC or DC fire alarm panels. (2) -FAP, -FM, or -AF options may not be specified together. (3) Available with remote capacity (LTXXX3) models only. (4) Only available on remote capacity and damp location models. FTSMKW FTSMKB PMLZTW PMLZTB (Order Separately) Side mount field kit (white) (a) Side mount field kit (black) (a) 121/2” Pendant mounting kit (white) 121/2” Pendant mounting kit (black) WGTW WGTCE VRS2 OMSSW0605 Wire guard (Wall mount) Wire guard (Ceiling or end mount) Vandal resistant shield (b) Outdoor remote lighting head - 6 Volt, 5 Watt sealed-beam type lamp White finish OMSSB0605 Outdoor remote lighting head - 6 Volt, 5 Watt sealed-beam type lamp Black Finish (a) FTSMKW and FTSMKB field kits are required for side mounting on all models. Accommodates left side mounting only. (b) For use with wall mounted units only. OMS Series outdoor lighting heads Matching Remote Fixtures A complete line of 6- and 12-volt matching remote fixtures in single and tandem lamp configurations is available for use with LZ Series high-capacity units or any other 6- or 12volt DC emergency lighting remote power sources. All remote fixtures are offered in black and white textured finishes with a choice of 5- or 10-watt halogen lamps. White Black Single Single Volts Watts LZRSW0605 LZRSB0605 6 5 LZRSW0610 LZRSB0610 6 10 LZRSW1205 LZRSB1205 12 5 LZRSW1210 LZRSB1210 12 10 43 NYXC New York City Tandem Unit Features • Designed to meet New York City specifications • Heavy 20 gauge metal enclosure with white or black finish • Exit plaques secured by channels • Single face eight inch high letters • Knockout directional chevron arrows • Available with two or three fully adjustable and lockable 7.2 watt thermoplastic lighting heads • High output LED lamps • Universal 120/277VAC operation W NE • • • • Wall mounting Completely self-contained 90-Minute emergency operation Environmentally coated, fully automatic solid state charger • Automatic low voltage battery disconnect • Charge rate indicator and test switch • Maintenance free battery • Temperature range: 0°C to 40°C (32°F to 104°F) • Listed to UL 924 Ordering Information NYXC S R B E 2 Options Series Operation Faces E - Emergency S - Single D - Double W - White B - Black R - Red Options Number of Lighting Heads Housing Finish Letter Color -0612 -TR (Add 12 watt lamps 2 - Two 3 - Three suffix to model) (1) Tamper resistant Options (Addoption suffix to model) (2) -TR Accessories (Order Separately) (1) 12 watt high-output lamps available on two-headed models only. (2) Provides two stainless steel tamper resistant locking screws. Accessories 40G (Order Separately) Wire guard (wall mount) Dimensions Power Consumption All Models 120VAC 7.0W 277VAC 7.2W * Wattage figures include LED lamps, transformers and electronics power requirements. Photometrics Horizontal Isofootcandle Distribution Standard 6V, 7.2W SBT Lamp B A C A B C D 15 1/2” 15” 4 1/4” 9 5/8” 24.4 cm 39.4 cm 38.1 cm 10.8 cm 44 D SMC Combination LED Exit/Emergency Light Features • Combines emergency light with energy saving LED exit • Adjustable 5.4 watt incandescent lampheads • Maintenance-free battery • Dual voltage – 120V/277VAC • Fast, easy installation • Snap together, modular construction • All components are integral to the exit housing, including battery • Accessible compartments add to ease of maintenance • Consumes as little as 4 watts for either a single or twin face sign • Uniform illumination of exit legend • Snap-out directional chevrons • Temperature range: 20°C to 30°C (68°F to 86°F) • UL 924 Listed W NE Ordering Information SMC 3 R Series E CB W Housing Finish Operation E - Emergency W - White B - Black Faces 3 - Universal Single or Double Mounting CB - Ceiling/Back E - End Letter Color R - Red G - Green Available March 1, 2006 Options (Add Accessories 41G suffix to model) Accessories (Order Separately) (Order Separately) Wire guard (wall or ceiling mount) Dimensions End Mount 13 3/8” (34 cm) 12 1/2” Ceiling or Back Mount 21 1/2” max. 1 4 /2” (54.6 cm) (11.4 cm) max. 12 1/2” (31.8 m) (31.8 cm) 10 1/8” (13.3 cm) 45 Sempra Diecast LED Exit Sign Features All Models • High-strength cast aluminum • Low-profile architectural styling • 5-minute installation • Long-life LED lamps • Bright, even illumination • Red and green letters • Single and double face models • White, black and black or white with brushed face finishes • Push-in wiring connectors • Universal end/ceiling/wall mount • Break-out, chevron arrows and TY ON mounting KOs N A R AR S L W E E • 120/277VAC, 60 Hz operation rdering nformation OD TIM OLIFE IM N CTRO LL SPE Emergency Models • Solid-state charger with low voltage disconnect • Maintenance-free NiCad battery • 2-hour emergency operation • Test switch and AC-On indicator • Available with Spectron® selftesting/self-diagnostic electronics with time-delay relay (TDR) standard • Lifetime warranty on LED strip, electronics and battery with Spectron® self-testing/selfdiagnostic models • Temperature range: 20°C to 30°C (68°F to 86°F) • UL 924 Listed A Ordering Information See Product Selector Guide for available models Special Wording Diffus- Options (Add suffix to model) Lifetime Warranty Sempra cast-aluminum emergency exit signs with the Spectron self-testing/self-diagnostic electronics system are guaranteed by Dual-Lite under normal and proper use, against defects in material and workmanship for the life of the product. The warranty covers all electronics, LED light strip and battery. ccessories (Ounit rder Separately) A Special Wording Open Face Diffuser Table* Option No. -SW1 -SW2 -SW3 -SW4 -SW5 -SW6 -SW7 -SW8 -SW9 -SW10 -SW11 Description TO EXIT NOT AN EXIT IN USE XRAY IN USE DARKROOM IN USE CAUTION DO NOT ENTER TEST IN PROGRESS ON AIR AREA OF REFUGE AREA OF REFUGE (w/wheelchair symbol) Option No. -SW12 -SW13 -SW14 -SW15 -SW16 -SW17 -SW18 -SW19 Description AREA OF RESCUE ASSISTANCE AREA OF RESCUE ASSISTANCE (w/wheelchair symbol) ELEVATOR RESTROOMS MEN MEN (w/symbol) WOMEN WOMEN (w/symbol) Other special wording diffusers available, consult factory. * To order special wording diffusers, add Option Number suffix to model number. Ex: SEDRWE-SW(10) Power Consumption Red AC Only Models: Green AC Only Models: Red Emergency Models: Green Emergency Models: 120VAC 2.6 watts 2.1 watts 3.8 watts 3.5 watts 277VAC 2.6 watts 2.1 watts 3.8 watts 3.5 watts *Wattage figures include LED lamps, transformer and electronics power requirements. LED lamp assemblies (red or green) consume less than 1 watt. Power factor, average: .8 (lagging) 46 Push-in quick-connect AC terminals Universal wall mounting KO pattern Wiring channel LED illumination strip Isolated, grounded 120/277VAC transformer Break-out chevron-style directional indicators Charger/transfer module Sealed nickel-cadmium battery Sempra Product Selector Guide AC Emergency Number Colors Model Model of Exit Stencil Numbers Numbers Faces Letters Housing Face(s) SESRW SESRWE Single Red White White SESGW SESGWE Single Green White White SESRWN SESRWNE Single Red White Brushed SESGWN SESGWNE Single Green White Brushed SESRB SESRBE Single Red Black Black SESGB SESGBE Single Green Black Black SESRBN SESRBNE Single Red Black Brushed SESGBN SESGBNE Single Green Black Brushed SEDRW SEDRWE Double Red White White SEDGW SEDGWE Double Green White White SEDRWN SEDRWNE Double Red White Brushed SEDGWN SEDGWNE Double Green White Brushed SEDRB SEDRBE Double Red Black Black SEDGB SEDGBE Double Green Black Black SEDRBN SEDRBNE Double Red Black Brushed SEDGBN SEDGBNE Double Green Black Brushed Options I -DC -2C -FAP -FM -AF -24K (Add suffix to model) Spectron self-testing/self-diagnostic electronics Remote DC operation (1)(4)(5) 2-circuit operation (1)(5) Fire alarm panel interface (3)(5) Flasher module (2)(5) Audible/Flasher module (2)(5) 220/240VAC, 60 Hz. operation (1) For use with AC models only. (2) For use with emergency models only. (3) Operates with 24-volt AC or DC fire alarm panels. (4) For emergency illumination of sign from remote 6-24 VDC power sources. (5) -DC, -2C, -FAP, -FM, -AF options may not be specified together. Accessories SER-E SEG-E PMCW PMCB WGLX WG-MLT WGLXC WGLXE (Order Separately) Emergency operation module (red models) * Emergency operation module (green models) * 121/2” Pendant mounting kit (white) 121/2” Pendant mounting kit (black) Wire guard (Wall mount) Wire guard (Wall mount) Wire guard (Ceiling mount) Wire guard (End mount) * For factory-equipped emergency models, see Product Selector Guide above. Dimensions 9 1/8” (23 cm) 10” (25.5 cm) 11 3/4” (30 cm) 12 5/8” (32 cm) 1 5/8” (4.14 cm) 47 Sempra MR Master/Remote Diecast LED Exit Signs Features All Models • High-strength, low-profile cast aluminum housing • Supplied as 2-sign, Master/Remote sets • 5-minute installation • Long-life LED lamps • Bright, even illumination • Red or green letters • Single and double face models N NTY O A • White, black and black or white R R E WA MODELS M with brushed face finishes I T E N LIF RIOnformation Ordering T C E P • Push-in wiring connectors ALL S • Universal end/ceiling/wall mount • Break-out, chevron arrows • 120/277VAC, 60 Hz operation Master Signs • Solid-state charger with low voltage disconnect • Maintenance-free NiCad battery • 90 minute emergency operation • Test switch and AC-On indicator • Available with Spectron® selftesting/self-diagnostic electronics with time-delay relay (TDR) standard • Lifetime warranty on LED strip, electronics and battery with Spectron® self-testing/self- diagnostic models • Temperature range: 20°C to 30°C (68°F to 86°F) • UL 924 Listed Remote Signs • Surface mounts to standard electrical boxes • Connects to Master sign using conventional wiring methods Ordering Information SEMR S R W E -FAP Series Options Operation Faces Blank - AC Only E - Emergency S - Single D - Double OLetter ptions Color R - Red G - Green (Add suffix to model) Housing Finish W - White B - Black WN - White with brushed face BN - Black with brushed face Lifetime Warranty Sempra cast-aluminum emergency exit signs with the Spectron self-testing/self-diagnostic electronics system are guaranteed by Dual-Lite under normal and proper use, against defects in material and workmanship for the life of the product. The covers all ccessories (Owarranty rder Separately ) electronics, LED light strip and unit battery. A Dimensions Master Signs 9 1/8” (23 cm) 10” (25.5 cm) 11 3/4” (30 cm) 12 5/8” (32 cm) 1 5/8” (4.14 cm) 12 3/8” (31.4 cm) Remote Signs 5 /8” (1.6 cm) 9 5/8” (24.4 cm) 48 Sempra MR Product Selector Guide AC Emergency Number Colors Model Model of Exit Stencil Numbers Numbers Faces Letters Housing Face(s) SEMRSRW SEMRSGW SEMRSRWN SEMRSGWN SEMRSRB SEMRSGB SEMRSRBN SEMRSGBN SEMRDRW SEMRDGW SEMRDRWN SEMRDGWN SEMRDRB SEMRDGB SEMRDRBN SEMRSRWE SEMRSGWE SEMRSRWNE SEMRSGWNE SEMRSRBE SEMRSGBE SEMRSRBNE SEMRSGBNE SEMRDRWE SEMRDGWE SEMRDRWNE SEMRDGWNE SEMRDRBE SEMRDGBE SEMRDRBNE Single Single Single Single Single Single Single Single Double Double Double Double Double Double Double Red Green Red Green Red Green Red Green Red Green Red Green Red Green Red White White White White Black Black Black Black White White White White Black Black Black White White Brushed Brushed Black Black Brushed Brushed White White Brushed Brushed Black Black Brushed SEMRDGBN SEMRDGBNE Double Green Black Brushed Options I -DC -2C -FAP -FM -AF -24K -VTR (Add suffix to model) Spectron self-testing/self-diagnostic electronics Remote DC operation (1)(4)(5) 2-circuit operation (1)(5) Fire alarm panel interface (3)(5) Flasher module (2)(5) Audible/Flasher module (2)(5) 220/240VAC, 60 Hz. operation Vandal/tamper resistant option (6) Accessories PMCW PMCB WGLX WG-MLT WGLXC WGLXE (Order Separately) Pendant mounting kit (white) (a) Pendant mounting kit (black) (a) Wire guard (Wall mount) (a) Wire guard (Wall mount) (a) Wire guard (Ceiling mount) (a) Wire guard (End mount) (a) (a) For use with Master exit signs only. (1) For use with AC models only. (2) For use with emergency models only. (3) Operates with 24-volt AC or DC fire alarm panels. (4) For emergency illumination of sign from remote 6-24 VDC power sources. (5) -DC, -2C, -FAP, -FM, -AF options may not be specified together. (6) Provides polycarbonate face shield and tamper-proof screws. Meets UL listing requirements for floor proximity use. Beveled, low-profile design on Remote signs meet ADA requirements and UL Listing requirements for floor proximity use with -VTR option Power Consumption Sempra MR signs equipped with -VTR vandal/tamper resistant option shield and hardware. Red AC Only Models: Green AC Only Models: Red Emergency Models: Green Emergency Models: 120VAC 2.6 watts 2.1 watts 3.8 watts 3.5 watts 277VAC 2.6 watts 2.1 watts 3.8 watts 3.5 watts *Wattage figures include LED lamps, transformer and electronics power requirements. LED lamp assemblies (red or green) consume less than 1 watt. Power factor, average: .8 (lagging) 49 Sempra SC An Severe Conditions Diecast LED Exit Signs Features All Models • High-strength cast aluminum • Low-profile architectural styling • 5-minute installation • Polycarbonate face shield provides additional protection against vandalism • Tamper-resistent screws prevent entry by unauthorized personnel • Long-life LED lamps • Bright, even illumination • Red and green letters • Single and double face models • White, black and black or white Severe Conditions Product Line with brushed face finishes rdering nformation • Push-in wiring connectors VandalTampering Damp Hot Cold • Universal end/ceiling/wall mount • Break-out, chevron arrows and TY ON mounting KOs N A R LS WAR E E • UL Damp Location listed D M O I LIFET ON M R • 120/277VAC, 60 Hz operation T C E P O I ALL S Emergency Models • Solid-state charger with low voltage disconnect • Maintenance-free NiCad battery • 90 minute emergency operation • Test switch and AC-On indicator • Available with Spectron® selftesting/self-diagnostic electronics with time-delay relay (TDR) standard • Lifetime warranty on LED strip, electronics and battery with Spectron® self-testing/self- diagnostic models • Temperature ranges: AC models: -20°C to 50°C (-4°F to 122°F) Emergency models: 0°C to 40°C (32°F to 104°F) Emergency models with -XTR option: -20°C to 50°C (-4°F to 122°F) • UL 924 Listed Ordering Information See Product Selector Guide for available models Lifetime Warranty Options (Add suffix to model) Sempra SC cast-aluminum emergency exit signs with the Spectron self-testing/self-diagnostic electronics system are guaranteed by Dual-Lite under normal and proper use, ccessories (Order Separately against defects in material and workmanship for the life of ) the product. The warranty covers all electronics, LED light strip and unit battery. A Push-in quick-connect AC terminals Universal wall mounting KO pattern Wiring channel LED illumination strip Polycarbonate face shield provided standard on all Sempra SC models Isolated, grounded 120/277VAC transformer Power Consumption Red AC Only Models: Green AC Only Models: Red Emergency Models: Green Emergency Models: 120VAC 2.6 watts 2.1 watts 3.8 watts 3.5 watts 277VAC 2.6 watts 2.1 watts 3.8 watts 3.5 watts *Wattage figures include LED lamps, transformer and electronics power requirements. LED lamp assemblies (red or green) consume less than 1 watt. Power factor, average: .8 (lagging) 50 Break-out chevron-style directional indicators Charger/transfer module Sealed nickel-cadmium battery Sempra SC Product Selector Guide AC Emergency Number Colors Model Model of Exit Stencil Numbers Numbers Faces Letters Housing Face(s) SCSRW SCSRWE Single Red White White SCSGW SCSGWE Single Green White White SCSRWN SCSRWNE Single Red White Brushed SCSGWN SCSGWNE Single Green White Brushed SCSRB SCSRBE Single Red Black Black SCSGB SCSGBE Single Green Black Black SCSRBN SCSRBNE Single Red Black Brushed SCSGBN SCSGBNE Single Green Black Brushed SCDRW SCDRWE Double Red White White SCDGW SCDGWE Double Green White White SCDRWN SCDRWNE Double Red White Brushed SCDGWN SCDGWNE Double Green White Brushed SCDRB SCDRBE Double Red Black Black SCDGB SCDGBE Double Green Black Black SCDRBN SCDRBNE Double Red Black Brushed SCDGBN SCDGBNE Double Green Black Brushed Options I -DC -2C -FAP -FM -AF -24K -XTR (Add suffix to model) Spectron self-testing/self-diagnostic electronics Remote DC operation (1)(4)(5) 2-circuit operation (1)(5) Fire alarm panel interface (3)(5) Flasher module (2)(5) Audible/Flasher module (2)(5) 220/240VAC, 60 Hz. operation Extreme temperature operation (2)(6) Accessories PMCW PMCB WGLX WG-MLT WGLXC WGLXE (Order Separately) 121/2” Pendant mounting kit (white) 121/2” Pendant mounting kit (black) Wire guard (Wall mount) Wire guard (Wall mount) Wire guard (Ceiling mount) Wire guard (End mount) (1) For use with AC models only. (2) For use with emergency models only. (3) Operates with 24-volt AC or DC fire alarm panels. (4) For emergency illumination of sign from remote 6-24 VDC power sources. (5) -DC, -2C, -FAP, -FM, -AF options may not be specified together. (6) For use with Sempra SC emergency models only (Spectron models excluded). Dimensions 9 1/8” (23 cm) 10” (25.5 cm) 11 3/4” (30 cm) 12 5/8” (32 cm) 1 5/8” (4.14 cm) 51 Sempra SC Wet Location Environmental LED Exit Sign Features Wet Location W NE All Models • Designed for wet location and high abuse applications • Full neoprene gasket • Durable cast aluminum housing in black finish • Polycarbonate face shields secured with stainless hardware • Universal ceiling, end or wall surface mounting • 120/277VAC operation standard • Bright, even illumination An • Red and green letter models • Snap-out chevron arrows Severe Conditions Product Line • High output, long-life LED lamps rdering nformation • Temperature range: 0°C to 45°C (32°F to 114°F) Damp Corrosive Wet Cold* O I *With Heater Option Emergency Models • Completely self-contained • Fully automatic, environmentally coated charger • Maintenance-free NiCad battery • Low voltage disconnect • Test switch and AC-On indicator • 90 minute operation • Optional 120 minute operation • Temperature range: 0°C to 45°C (32°F to 114°F) • Temperature range with heater -40°C to 45°C option: (-40°F to 114°F) • Vandal-resistant housing with tamper-resistant screws • Listed to UL 924 Availability To Be Announced Ordering Information SCWL S Series R B E Operation Faces Options Blank - AC Only E - Emergency S - Single D - Double Letter Color R - Red G - Green Options U -AA (Add Mounting Exit Housing Color U - Universal A (OrdertoSeparately Occessories ptions (Add suffix model) ) - Black suffix Bto model) W - White -AA -FM -AR120 -HTR1 -HTR2 Dimensions (1) -AA, -FM, -HTR1, and -HTR2 options may not be specified together. (2) For use with emergency models only. A B C C D E 4” 10” 6.2” 9” 9” 14” 10.2 cm 25.4 cm 15.8 cm 22.9 cm 35.6 cm Accessories PMSWL E 52 B (Order Separately) 12” Pendant mounting kit C D A Audible alarm (1)(2) Flasher module (1)(2) 120 minute emergency operation (2) Internal heater - 120VAC (1)(2) Internal heater - 277VAC (1)(2) Sempra SERS Recessed Cast Aluminum LED Exit Sign Features All Models • High-strength cast aluminum • Compact, low-profile style • Fast, easy installation • Long-life LED lamps • Bright, even illumination • Red and green letters • Rigid, high impact acrylic letter panel • White, black and black or white with brushed face finishes • Plug-together wiring connectors • Break-out, chevron arrows and mounting KOs • 120/277VAC, 60 Hz operation Emergency Models • Solid-state charger with low voltage disconnect • Maintenance-free NiCad battery • 2-hour emergency operation • Test switch and AC-On indicator • Available with Spectron® selftesting/self-diagnostic electronics with time-delay relay (TDR) standard • Lifetime warranty on LED strip, electronics and battery with Spectron® self-testing/selfdiagnostic models • Temperature range: 20°C to 30°C (68°F to 86°F) nformation • UL 924 Listed Ordering I N NTY O A R R A DELS ME W LIFETI CTRON MO E ALL SP Ordering Information SERS R WN E -AF Series Options Letter Color Lifetime Warranty Operation R - Red G - Green Blank - AC Only E - Emergency Sempra cast-aluminum emergency exit signs with the Spectron self-testing/self-diagnostic electronics system are guaranteed by Dual-Lite under normal and proper use, against defects in material and workmanship for the life of the product. The warranty covers all electronics, LED light strip and unit battery. Housing Finish W - White B - Black WN - White with brushed face BN - Black with brushed face Options I -DC -2C -FAP -FM -AF -VTR -LRBB (Add suffix to model) Spectron self-testing/self-diagnostic electronics Remote DC operation (1)(4)(5) 2-circuit operation (1)(5) Fire alarm panel interface (3)(5) Flasher module (2)(5) Audible/Flasher module (2)(5) Vandal/tamper resistant option (6) Sign assembly less rough-in back box (7) (1) For use with AC models only. (2) For use with emergency models only. (3) Operates with 24-volt AC or DC fire alarm panels. (4) For emergency illumination of sign from remote 6-24 VDC power sources. (5) -DC, -2C, -FAP, -FM, -AF options may not be specified together. (6) Provides polycarbonate face shield and tamper-resistant screws. Meets UL listing requirements for floor proximity use. (7) Allows ordering of rough-in back box separately for installation prior to sign shipment. Add “-LRBB” suffix to exit model number if RBB accessory kit is to be ordered separately. Accessories (Order Separately) RBB Rough-in back box kit WGLX Wire guard (Wall mount) WG-MLT Wire guard (Wall mount) Dimensions Rough-In Back Box Power Consumption Red AC Only Models: Green AC Only Models: Red Emergency Models: Green Emergency Models: 120VAC 2.6 watts 2.1 watts 3.8 watts 3.5 watts 277VAC 2.6 watts 2.1 watts 3.8 watts 3.5 watts 9 5/8” (24.4 cm) *Wattage figures include LED lamps, transformer and electronics power requirements. LED lamp assemblies (red or green) consume less than 1 watt. Power factor, average: .8 (lagging) 53 NYDC New York City Cast Aluminum LED Exit Features AC Models • Designed to meet New York City specifications • All diecast aluminum construction • White, black and black with brushed face finishes • Break-out directional chevrons • Single and double face models with eight inch letters • Wall/ceiling/end mounting • Dual voltage – 120/277VAC • Bright and even illumination • Long-life LED lamps W NE Emergency Models • Long life NiCad battery • 90 minute emergency operation • Test switch and AC-On indicator • Environmentally coated, fully automatic charger • Temperature range: 0°C to 45°C (32°F to 113°F) • Listed to UL 924 Ordering Information NYDC S R B A -FM Options Series Operation Faces A - AC Only E - Emergency S - Single D - Double Housing Finish Letter Color W - White B - Black BN - Black with brushed face R - Red Options (Add suffix to model) O (Add suffix to model) -FM ptions Flasher module (1)(2) -AA Audible alarm module Available in white, black and black with brushed face finishes Accessories (Order Separately) (1)(2) (1) For use with emergency models only. (2) -FM and -AA options may not be specified together. Accessories PMNYW PMNYB WGTW WGTCE (Order Separately) Dimensions Pendant mounting kit (white) Pendant mounting kit (black) Wire guard (Wall mount) Wire guard (Ceiling mount) B* A* C Power Consumption * Add 1“ (2.5 cm) for mounting canopy on ceiling or end mounted models 120VAC 277VAC AC Only Models 2.4W 2.4W Emergency Models 3.4W 3.5W * Wattage figures include LED lamps, transformers and electronics power requirements. 54 A B C 2 5/8” 11” 161/4” 27.9 cm 41.3 cm 6.7 cm LN4X Wet Location LED Exit Signs Features AC Models • UL type 4X enclosure for indoor/outdoor use • Easily installed to wall surfaces • Suitable for use in damp, wet, hose-down and corrosive locations • Polycarbonate housing • 120/277VAC operation standard • Bright, even illumination • Red and green letter models • Snap-in chevron arrows • Long-life LED lamps • Temperature range: 0°C to 40°C (32°F to 104°F) Emergency Models • Suitable for use in damp, wet and corrosive locations • Completely self-contained • Fully automatic, solid-state charger • Maintenance-free NiCad battery • Low voltage disconnect • Test switch and AC-On light • Available with Spectron® selftesting/self-diagnostic electronics with time-delay relay (TDR) standard • 120 minute operation • Temperature range: 10°C to 40°C (50°F to 104°F) nformation • UL 924 Listed An Severe Conditions Product Line Ordering I Damp Wet Vandal & Tampering Cold Corrosive Ordering Information LN4X R W Series E -FAP Operation Blank - AC Only E - Emergency Letter Color R - Red G - Green Exit Face Color Options W - White Accessories suffix to model) (Order Separately) (1)(2) 120VAC 277VAC Red AC Only Models 2.6 watts 2.6 watts Green AC Only Models 2.1 watts 2.1 watts Red Emergency Models 3.8 watts 3.8 watts Green Emergency Models 3.5 watts 3.0 watts Power factor, average: .8 (lagging) Dimensions ➤ (1) Add “I” Spectron self-testing/self-diagnostic option suffix immediately after base model number. Example: LN4XRWEI (2) For specification with emergency models only. (3) For use with AC models only. (4) Operates with 24-volt AC or DC fire alarm panels. (5) For emergency illumination of sign from remote 6-24 VDC power sources. (6) -FAP, -XTRFAP, -FM or -DC options may not be specified together. (7) -2C and -XTRFAP or -FAP options may be specified together. (8) Not for use with self-testing Spectron models. (9) Provides an operating temperature range of -20°C to 50°C (-4°F to 122°F) Power Consumption 11 3/4” (29.8 cm) ➤ 15 3/4” ➤ Spectron self-testing/self-diagnostic electronics Extreme temperature operation (2)(8)(9) 2-circuit operation (3)(7) Fire alarm panel interface (4)(6)(7) Extreme temperature operation fire alarm panel interface (2)(4)(6)(7)(8)(9) Flasher module (2)(6) Remote DC operation (3)(5)(6) Tamper-proof cover screws (includes tool) ➤ I -XTR -2C -FAP -XTRFAP -FM -DC -TR (Add (40 cm) 5 16 /8” (42.2 cm) ➤ ➤ ➤ Options 5 1/4” ➤ (13.3 cm) 55 Freedom LED Aluminum LED Exit Signs Features Emergency Models • Solid-state charger with low voltage disconnect • 6-volt, maintenance-free battery • User-selectable constant on or flashing emergency illumination • Up to 12 hour operation • Test switch, AC-On and charge indicator lights • Temperature range: 10°C to 40°C (50°F to 104°F) • Damp location listed • UL 924 Listed All Models • Vinyl-clad aluminum housing • Polycarbonate face shield standard • Easy to install • Long-life LED lamps • Red and green letters • Single and double face models • Six decorator finishes offered • End, ceiling or wall mount • Snap-out, chevron arrows • Damp location listed • 120/277VAC, 60 Hz operation An Damp Severe Conditions Product Line Ordering Information LED 2 EM Series R WW -TR R - Red G - Green Available Colors WW - White WA - White with Brushed Aluminum Face BB - Black BA - Black with Brushed Aluminum Face TT - Brass ZZ - Antique Brass Operation AC - AC Only EM - Emergency Options Single Double Face Face 12 Hours 8 Hours 6 Hours 4 Hours Housing Finish 1 - Single Face 2 - Double Face -TR -2C -FAP -BPR Flashing Mode Constant On Mode Options Letter Color Faces -DC Discharge Times (Add Antique Brass Black Black/Brushed Face Brass White White/Brushed Face Accessories suffix to model) Remote DC operation(2)(3)(5) Tamper resistent screws 2-circuit operation(2)(3)(6) Fire alarm panel interface (flasher)(4)(5)(6) Beeper module(1)(6) (Order Separately) VRS3 Vandal resistant shield WGTCE Wire guard (Ceiling/End mount) WGTW Wire guard (Wall mount) (1) For specification with emergency models only. (2) For use with AC models only. (3) For emergency illumination of sign from remote 12 through 48 VDC power sources. (4) Operates with 24-volt AC or DC fire alarm panels. (5) -FAP, and -DC options may not be specified together. (6) -2C, -BPR and -FAP options may be specified together. Dimensions Power Consumption 56 Single Face Models 120VAC 277VAC Double Face Models Red AC Only Models 4.47 watts 4.47 watts 6.80 watts 6.80 watts 120VAC 277VAC Green AC Only Models 4.68 watts 4.64 watts 6.70 watts 6.70 watts Red Emergency Models 4.99 watts 4.99 watts 7.27 watts 7.22 watts A B C Green Emergency Models 4.96 watts 4.93 watts 7.65 watts 7.67 watts 7 1/2” 8.0” 31/8” Power factor, average: .8 (lagging) 19 cm 20 cm 7.9 cm 30.8 cm 32.1 cm 1.3 cm 15.2 cm 10.8 cm D E 121/8” 12 5/8” F G H 1/ 2” 6.0” 41/4” LEDS Low-Profile Aluminum LED Exit Signs Features Emergency Models • Solid-state charger with low voltage disconnect • Maintenance-free Ni-Cad battery • 90-minute emergency operation • Test switch and AC-On indicator light • Temperature range: 10°C to 40°C (50°F to 104°F) • Damp location listed • UL 924 Listed All Models • Vinyl-clad aluminum housing • Compact, low-profile style • Easy to install • Long-life LED lamps • Red and green letters • Single, double and universal single/double face models • Six decorator finishes offered • End, ceiling or wall mount • Snap-out, chevron arrows • Damp location listed • 120/277VAC, 60 Hz operation An Damp Severe Conditions Product Line Ordering Information LEDS U AC Series R Options Letter Color R - Red G - Green Faces WW - White WA - White with Brushed Aluminum Face BB - Black BA - Black with Brushed Aluminum Face TT - Brass ZZ - Antique Brass Operation AC - AC Only EM - Emergency Options (Add Antique Brass Black Black/Brushed Face Brass White White/Brushed Face Housing Finish 1 - Single Face 2 - Double Face U - Universal Single/Double Face -TR Available Colors BA -TR Accessories suffix to model) Tamper resistent screws VRS3 WGLX WGLXC WGLXE (Order Separately) Vandal resistant shield Wire guard (Wall mount) Wire guard (Ceiling mount) Wire guard (End mount) Dimensions A B C D E F G H 6.0” 4 1/4” 7 1/ 2” 8.0” 1 5/8” 12 1/8” 12 5/8” 1/ 2” 19 cm 20 cm 4.1 cm 30.8 cm 32.1 cm 1.3 cm 15.2 cm 10.8 cm 57 NYX New York City LED Exit Sign Features AC Models • Designed to meet New York City specifications • 20 gauge metal enclosure • White or black finish • Break-out directional chevrons • Universal single/double face models with eight inch letters • Wall/ceiling/end mounting • Dual voltage – 120/277VAC • Bright and even illumination • Long-life LED lamps W NE Emergency Models • Long life NiCad battery • 90 minute emergency operation • Test switch and AC-On indicator • Environmentally coated, fully automatic charger • Temperature range: 0°C to 45°C (32°F to 113°F) • Listed to UL 924 Ordering Information NYX U R W E -FM Options Series Operation Faces A - AC Only E - Emergency U - Universal single/double face Housing Finish Letter Color W B R - Red Options -FM -AA -TR (Add - White - Black suffix to model) (1)(2) Flasher module Audible alarm module (1)(2) Tamper resistant option (3) Accessories PMNYW PMNYB WGTW (1) For use with emergency models only. (2) -FM and -AA options may not be specified together. (3) Provides two tamper-resistant locking screws. (Order Separately) Pendant mounting kit (white) Pendant mounting kit (black) Wire guard (Wall mount) Dimensions B* A* Power Consumption AC Only Models Emergency Models 120VAC 2.4W 3.4W 277VAC 2.4W 3.5W * Wattage figures include LED lamps, transformers and electronics power requirements. 58 C * Add 1“ (2.5 cm) for mounting canopy on ceiling or end mounted models A B C 23/8” 101/2” 141/2” 26.7 cm 36.8 cm 6.0 cm CMX Chicago Low Profile Exit Sign Features All Models • City of Chicago approved • 22-gauge metal enclosure with white or black finish • Translucent glass diffuser • Six-inch letters • Full length, silkscreened directional arrows • Standard, incandescent AC lamps (Fluorescent lamps optional) • Standard 120 VAC (277 VAC optional on AC models) • Wall, end or ceiling mounting • Downlighting aperture Emergency Models • Completely self-contained emergency power pack • 120-minute operation • Fully automatic, solid-state charger • Automatic, low-voltage battery disconnect • AC-On indicator and test switch • Maintenance-free long-life leadacid battery • Universal 120/277VAC operation • UL Listed W NE City of Chicago Approval No. 9823 Ordering Information CMX S E 6 -AF Options Series Faces S - Single Face D - Double Face Exit Legend Single face models 3 - “EXIT” (no arrows) 6 - “EXIT” (right arrow) 9 - “EXIT” (left arrow) 12 - “EXIT” (double arrow) 2 - “STAIRS” (no arrows) 5 - “STAIRS” (right arrow) 8 - “STAIRS” (left arrow) 11 - “STAIRS” (double arrow) Operation Blank - AC Only E - Emergency Options -277V -DC6 -DC12 -B -FL -FAP -AF -PH (1) (2) (3) (4) (5) (Add suffix to model) (1) 277 VAC operation 6 VDC emergency socket and lamp (1) 12 VDC emergency socket and lamp (1) Black finish 7 watt fluorescent AC lamps Fire alarm panel interface (2)(3)(4) Audible flasher alarm (3)(4)(5) Phosphorescent glass diffuser panel For use with AC models only. Operates with 24-volt AC or DC fire alarm panels. -FAP and -AF options may not be specified together. -FAP and -AF options not available with fluorescent lamp models. -AF option for use with emergency models only. Double face models 18 - “EXIT” (no arrows) 21 - “EXIT” (right/left arrow) 24 - “EXIT” (double arrow) 17 - “STAIRS” (no arrows) 20 - “STAIRS” (right/left arrow) 23 - “STAIRS” (double arrow) Accessories CKW CKB PMKW PMKB WGMLT WGTW WGTCE VRS2 (Order Separately) Canopy mounting kit (white) Canopy mounting kit (black) Pendant mounting kit (white) Pendant mounting kit (black) Wire guard (wall mount - AC models) Wire guard (wall mount - emergency models) Wire guard (ceiling/end mount - AC and emergency models) Vandal resistant shield (fits all models) Dimensions Power Consumption AC Only Exits Emergency Exits Incandescent Models Fluorescent Models 120/277VAC 40 watts 120/277VAC 18 watts 50 watts 28 watts C B A A B C 91/2” 141/2” 12 3/4” 32.4 cm 24.1 cm 36.8 cm D D 21/2” 6.4 cm 59 LE Recessed Mounting Edge-Lit LED Exit Signs Features AC Models • Ceiling, wall or end mounted models for recessed installations • Extruded aluminum construction • Available in six color finishes • Molded acrylic plaque • Red and green letter models • Clear, white or mirror background • Silkscreened chevron arrows • Long life LED lamps • Bright, even letter illumination • Energy-saving operation • Universal rough-in box • Easy to install • 120/277VAC, 60 Hz operation Emergency Models • Solid-state charger • Maintenance-free NiCad battery • Low voltage disconnect • Test switch and AC-On light • Available with Spectron® selftesting/self-diagnostic electronics with time-delay relay (TDR) standard • Temperature range: 20°C to 30°C (68°F to 86°F) • UL 924 Listed Ordering Information LE C D Series R C N Directional Arrows LE - Recessed mount X - No arrows EXIT R - Right arrow* EXIT> L - Left arrow*C - L/R arrows** Mounting C - Ceiling mount W - Wall mount E - End mount * Not for use with double face models. Use “C” L/R arrow designator ** Double face models only. Provides reversible right or left arrow indicator Faces S - Single D - Double* Options (Add * Not for use with wall mounted models suffix to model) E -FM Operation A - AC only E - Emergency Options See “Options” section Standard Plaque Backgrounds Single face models = clear Double face models = mirror - Satin Aluminum - White See “Options” for alternate - Chrome backgrounds. - Black ccessories (Order Separately) - Satin brass Trim/Housing Finish N W C B S Z - Dark Bronze A Letter Color R - Red G - Green Satin Aluminum White Chrome Black Satin Brass Dark Bronze Wall mount model Power Consumption Single Double Face Face Red AC Only Models 2.2W 3.7W Green AC Only Models 2.5W 4.4W Red Emergency Models Green Emergency Models 3.3W 3.6W 4.7W 5.2W * Wattage figures include LED lamps, transformers and electronics 60 End mount model Options I -XK -W -M -8L -2C -FAP -FM -AF -DC -24K (Add suffix to model) Spectron self-testing/self-diagnostic electronics Recessed mount exit sign less rough-in kit (1) White plaque background Mirror plaque background (2) 8 inch letter plaque (red letters only) (10)(11) 2-circuit operation (3)(8) Fire alarm panel interface (5)(7)(8) Flasher module (4)(7) Audible/flasher module (4)(7) Remote DC operation (3)(6)(7) 220/240VAC, 60 Hz operation (9) (1) Allows ordering of rough-in kit separately for recessed mount (LE) models. See “Accessories”. (2) For use with single face models only. Standard on double face models. (3) For use with AC models only. (4) For specification with emergency models only. (5) Operates with 24-volt AC or DC fire alarm panels. (6) For emergency illumination of sign from remote 6-24 VDC power sources. (7) -FAP, -FM, -AF or -DC options may not be specified together. (8) -2C and -FAP options may be specified together. (9) Rough-in kit may not be ordered separately on models specified with -24K option. (10) LE exit models with 8” plaques registered under NYC-BEC Calendar Number 42135 for use in New York City. (11) Single face LE exit signs specified with the -8L option are supplied without backgrounds. Double face models specified with the -8L option are supplied with mirror backgrounds. Accessories LE (Order Separately) URK Universal rough-in kit (b) URK2C Universal 2-circuit rough-in kit (a)(b)(c) (a) For use with AC models only. (b) Rough-in kit may not be ordered separately on models specified with -24K option. (c) Must be ordered in conjunction with -2C option on exit sign To Order Rough-In Kit Separately To order rough-in kit only for early installation, add “-XK” option suffix to exit model number and order “URK” or “URK2C” kit separately. Universal Rough-In Kit Dimensions Rough-In Kit Ceiling Mount Application End Mount Application Wall Mount Application 61 LES Surface Mounting AC Edge-Lit LED Exit Signs Features • Long life LED lamps • Bright, even letter illumination • Energy-saving operation • Easy to install • 120/277VAC, 60 Hz operation • Temperature range: 20°C to 30°C (68°F to 86°F) • UL Listed AC Models • Ceiling, wall or end mounted models for surface installations • Extruded aluminum construction • Available in six color finishes • Molded acrylic plaque • Red and green letter models • Clear, white or mirror background • Silkscreened chevron arrows Ordering Information LES C S Series C N Directional Arrows LES - Surface mount Mounting * Not for use with double face models. Use “C” L/R arrow designator ** Double face models only. Provides reversible right or left arrow indicator Faces Options A -M Operation A - AC only X - No arrows EXIT R - Right arrow* EXIT> L - Left arrow* C - L/R arrows** C - Ceiling mount W - Wall mount E - End mount S - Single D - Double* R (Add * Not for use with wall mounted models suffix to model) Options See “Options” section Standard Plaque Backgrounds Single face models = clear Double face models = mirror - Satin aluminum - White See “Options” for alternate back- Chrome grounds. - Black ccessories (Order Separately) - Satin Brass Trim/Housing Finish N W C B S Z - Dark bronze A Letter Color R - Red G - Green Satin Aluminum White Chrome Black Satin Brass Dark Bronze Power Consumption Single Double Face Face Red AC Only Models 2.5W 4.0W Green AC Only Models 2.6W 4.5W * Wattage figures include LED lamps, transformers and electronics power requirements. 62 End mount model Options -W -M -8L (Add LES suffix to model) White plaque background Mirror plaque background (1) 8 inch letter plaque (red letters only) (2)(3) (1) For use with single face models only. Standard on double face models. (2) LES exit models with 8” plaques registered under NYC-BEC Calendar Number 42135 for use in New York City. (3) Single face LES exit signs specified with the -8L option are supplied without backgrounds. Double face models specified with the -8L option are supplied with mirror backgrounds. Ceiling mount model Dimensions Ceiling Mount Application Wall Mount Application End Mount Application 63 NYE New York City Recessed Edge-Lit Exit Features AC Models • Designed to meet New York City specifications • Recessed ceiling or wall mount models • Extruded aluminum construction • Available in two color finishes • Acrylic plaque • Eight-inch red letter models • Clear, white or mirror background • Applique chevron arrows • Long life LED lamps W NE • Bright, even letter illumination • Energy-saving operation • Easy to install • 120/277VAC, 60 Hz operation Emergency Models • Environmentally coated, fully automatic charger • Maintenance-free NiCad battery • Low voltage disconnect • Test switch and AC-On indicator • Temperature range: 0°C to 45°C (32°F to 113°F) • Listed to UL 924 Ordering Information NYE C D R N E -W Operation Series A - AC only E - Emergency NYE - Recessed mount Mounting C - Ceiling W - Wall Trim/Housing Finish Options See “Options” section N - Satin aluminum W - White Faces S - Single D - Double* * Not for use with wall mounted models Letter Color R - Red Options (Add suffix to model) Options (Add (Order Separately) suffix to model) -LRBB -W -M Recessed mount exit sign less rough-in backbox (1) White exit face background Mirrored exit face background (1) Allows ordering of rough-in backbox separately. See “Accessories”. Accessories Accessories Dimensions D (Order Separately) NYC-RBB Rough-in backbox E F Power Consumption 120VAC 277VAC AC Only Models 3.2W 3.2W Emergency Models 4.0W 3.9W B A * Wattage figures include LED lamps, transformers and electronics C A B C D E F G H 131/2” 14” 165/8” 173/8” 193/16” 305/8” 23/4” 93/4” 24.8 cm 34.2 cm 35.6 cm 42.2 cm 44.1 cm 48.8 cm 77.8 cm 7.0 cm 64 NYES New York City Surface Edge-Lit Exit Features AC Models • Designed to meet New York City specifications • Surface mount design • Wall, ceiling or end mounted models • Extruded aluminum construction • Available in two color finishes • Acrylic plaque • Eight-inch red letter models • Clear, white or mirror background • Applique chevron arrows • Long life LED lamps • Bright, even letter illumination • Energy-saving operation • Easy to install • 120/277VAC, 60 Hz operation Emergency Models • Environmentally coated, fully automatic charger • Maintenance-free NiCad battery • Low voltage disconnect • Test switch and AC-On indicator • Temperature range: 0°C to 45°C (32°F to 113°F) • Listed to UL 924 W NE Ordering Information NYES C D R N E -W Operation Series A - AC only E - Emergency NYES - Surface mount Mounting C - Ceiling W - Wall E - End Trim/Housing Finish Options N - Satin aluminum W - White Faces See “Options” section S - Single D - Double* * Not for use with wall mounted models Letter Color R - Red Options (Add suffix to model) Options -W -M (Add Accessories (Order Separately) Dimensions suffix to model) White exit face background Mirrored exit face background D E F B A Power Consumption 120VAC 277VAC AC Only Models 3.2W 3.2W Emergency Models 4.0W 3.9W * Wattage figures include LED lamps, transformers and electronics C A B C D E F 14” 17” 165/8” 21/4” 10” 131/2” 25.4 cm 34.3 cm 35.6 cm 43.2 cm 42.2 cm 5.7 cm 65 DEX Special Wording Incandescent Signs Features AC Models • Thermoplastic housing • Steel faceplate • Polyester fiberglass special wording open face diffuser • Acrylic downlight lens • Canopy for ceiling or end mount • Universal directional chevron arrow knockouts • Tamper resistant screws supplied • 120V standard • AC illumination provided by two 145V, 15T6 incandescent lamps • Suitable for damp locations (AC models only) Emergency Models • Maintenance-free battery • High impact housing • Dual voltage – 120V/277VAC • Two 6V, 3.7W DC lamps for emergency operation • Temperature range: 20°C to 30°C (68°F to 86°F) Ordering Information DEX 1 EMFA R Series Background Color R – Red G – Green W – White Faces 1 - Single 2 - Double Special Wording Option No. Operation Letter Color Blank – AC-Only 120VAC EMFA – Emergency 120/277VAC R G W B Options (Add See table at right – Red – Green – White – Blue Option No.* -SW1 -SW2 -SW3 -SW4 -SW5 -SW6 -SW7 -SW8 -SW9 -SW10 -SW11 -SW12 -SW13 -SW14 -SW15 -SW16 -SW17 -SW18 -SW19 Description TO EXIT NOT AN EXIT IN USE XRAY IN USE DARKROOM IN USE CAUTION DO NOT ENTER TEST IN PROGRESS ON AIR AREA OF REFUGE AREA OF REFUGE (w/wheelchair symbol) AREA OF RESCUE ASSISTANCE AREA OF RESCUE ASSISTANCE (w/wheelchair symbol) ELEVATOR RESTROOMS MEN MEN (w/symbol) WOMEN WOMEN (w/symbol) rder Accessories suffix to model) Accessories WG-MLT WGLXC WGTCE PMEXW PMEXB VRS3 Special Wording Table W -SW3 (O Separately) Other Special Wording models available. Consult Factory. * To order special wording diffusers, add Option Number suffix to model number. Ex: DEX1EMFARW-SW10 (Order Separately) Wire guard (wall mount - all models) Wire guard (ceiling mount - AC models only) Wire guard (end mount - all models) 12” pendant stem and canopy kit – white 12” pendant stem and canopy kit – black Vandal resistant shield Dimensions 11” (279 mm) 5” (127 mm) CANOPY 1 /2” (13 mm) 4 3/4” (120 mm) Power Pack 11” (279 mm) 2 1/2” (64 mm) 8” (204 mm) 7 1/2” (191 mm) 5 1/2” (140 mm) 11 1/2” (292 mm) 66 3 1/4” (83 mm) (EMFA models) 3 2 /8” (60 mm) 1 /2” (13 mm) SlimLite Series CV Series CVEC Series CV3 Series CVT Series CVD Series CVER Series Fixed Lens Emergency Lights................................................... 68 Emergency Lights................................................................... 69 High Capacity Emergency Lights.............................................. 70 LED Exit Signs..................................................................................71 Tandem Units. ....................................................................... 72 Diecast LED Exit Signs......................................................................73 67 Recessed Mounting Edge-Lit LED Exit Signs...................................74 SlimLite Contemporary Emergency Light Features • Easy to install • Sleek, low profile design • Flame rated, UV stable thermoplastic housing • Bright white finish • 6 volt, T-5 incandescent lamps • Acrylic fresnel lens provides a focused beam pattern • Adjustable lamp socket • Maintenance-free battery • Universal 120/277VAC operation 12W • Fully-automatic, temperature- compensated, solid-state charger • Reverse polarity and short circuit protection • AC lockout • Low-voltage battery disconnect • Test switch and AC-On light • Temperature range: 20°C to 30°C (68°F to 86°F) • Meets ADA specifications • UL 924 Listed Ordering Information Standard Model SL1 Voltmeter Model SL1-V Also available in black finish Options (Add suffix catalogto number) O ptions (A dd to suffix model) -B -6H Accessories (Order Separately) Vandal resistant shield VRS WGLZ Wire guard Black housing 6 watt halogen lamps Product Selector Options (Add suffix to model) Accessories Electrical (Order Separately) Base Output Watts AC Input Catalog Output 1.5 2 3 4 Standard Remote Number Volts Hours Hours Hours Hours Volts Amps Watts Lamp Capability SL1, SL1-V 6 12.0 -- -- - 120 .050 6.0 277 .020 6.0 5.4W No Dimensions 5 1/8” (13 cm) TEST/ESSAI CHARGE 11 3/4” (30 cm) 68 2 1/4” (5.7cm) Designer Emergency Light Features • Fast, easy installation • Snap-together design • Compact, low-profile style • Injection molded high impact, UV stabilized thermoplastic • White finish • Standard and damp location models • Remote capacity models • High output incandescent lamps • Maintenance-free battery • Dual voltage – 120/277VAC • Fully automatic charger • Automatic low-voltage battery disconnect and transformer isolation protection • Universal mounting plate • Test switch and LED AC-On light • Temperature range: 20°C to 30°C (68°F to 86°F) Damp location models: 10°C to 40°C (50°F to 104°F) • UL 924 Listed Ordering Information Standard Models: Information CV2 (6V, 12W) CV3 (6V, 18W) Ordering Example: EDS4-EV1 Damp Location Models: Options -V CV2D (6V, 12W) (Add CV 11W to 30W CV3D (6V, 18W) W NE CV5 (6V, 30W) CV5D (6V, 30W) Accessories suffix to model) Voltmeter (Order Separately) SRHSW0605 Matching remote head - single (white) SRHDW0605 Matching remote head - twin (white) OMSSB0605 Single outdoor lighting head (black) OMSDB0605 Twin outdoor lighting head (black) PMLZTW Pendant mounting kit (white) (a) PMLZTB Pendant mounting kit (black) (a) WGEL Wire guard (a) Not available for use with CV5 and CV5D models. Options (Add Matching remote head Accessories suffix to model) Outdoor lighting head (Order Separately) Product Selector Base Catalog Output Number Volts 1.5 Hrs. Electrical Output Watts 2 Hrs. 3 Hrs. 4 Hrs. Input Amps Input Watts Standard Remote 120V 277V 120/277V Lamp Capability CV2 6 12 -- -- -- .040 .020 4.0 5.4W No CV3 6 18 13 -- -- .040 .020 4.0 5.4W Yes CV5 6 30 22 15 12 .130 .060 14.0 5.4W Yes CV2D 6 11 -- -- -- .040 .020 4.0 5.4W No CV3D CV5D 6 6 17 27 12 20 -- 13 -- -- .040 .130 .020 .060 4.0 14.0 5.4W 5.4W Yes Yes Photometrics Dimensions Horizontal Isofootcandle Distribution 15 7/8”-Min. 19 3/4”-Max. 4 3/4”-Min. 6 3/4”-Max. (40.3 cm)-Min. (50.2 cm)-Max. (12.1 cm)-Min. (17.1 cm)-Max. 6 Volt, 5.4 Watt SBT Lamp 5 3/8” (13.7 cm) 69 CVEC Commercial Emergency Light Features • Injection molded high impact, UV stabilized thermoplastic • Standard white housing • T-5 incandescent lamps • Lampheads may be top or side mounted • Most models capable of powering remote lampheads • Maintenance-free battery • Dual voltage – 120/277VAC • Automatic low voltage disconnect • Thermally compensated charger W NE 15W to 100W • Regulated charge voltage • Automatic low voltage disconnect • Reverse polarity protection • Filtered charger output • Universal wall mounting plate • Short circuit protection • AC lockout • Test switch and AC-On light • Temperature range: 20°C to 30°C (68°F to 86°F) • UL 924 Listed Ordering Information Standard Models: Options -V CVEC15 (Add CVEC30 CVEC 50 CVEC50-12V CVEC100-12V Accessories suffix to model) Voltmeter (Order Separately) Wire guard (a) Wire guard (b) Matching 6-volt remote head - single Matching 6-volt remote head - twin Matching 12-volt remote head - single Matching 12-volt remote head - twin 40G 41G SRHSW0607 SRHDW0607 SRHSW1207 SRHDW1207 (a) For top mounted heads on CVEC 15 and 30 watt models (b) For top mounted heads on CVEC 50 and 100 watt models and side mounted heads on CVEC 15 and 30 watt models. Options (Add Accessories suffix to model) (Order Separately) Product Selector Electrical Standard Output Output Watts Input Amps Input Watts Standard Remote Models Volts 1.5 Hrs. 2 Hrs. 3 Hrs. 4 Hrs. 120V 277V 120 277V Lamp Capability CVEC15 6 15 -- -- -- .07 .03 8.4 8.8 7.2W No CVEC30 6 30 22 15 12 .07 .03 8.4 8.8 7.2W Yes CVEC50 6 50 38 25 20 .17 .08 20 20 7.2W Yes CVEC50-12V 12 50 38 25 20 .11 .05 13 14 9.0W Yes CVEC100-12V 12 100 76 54 44 .32 .14 39 28 9.0W Yes Photometrics Horizontal Isofootcandle Distribution 6 Volt, 7.2 Watt SBT Lamp 70 12 Volt, 7.2 Watt SBT Lamp Dimensions 15 and 30W Models 50 and 100W Models CV3 Thermoplastic LED Exit Sign Features • Damp location listed • 120/277VAC, 60 Hz operation Emergency Models • Solid-state charger with low voltage disconnect • Maintenance-free NiCad battery • 2 hour emergency operation • Test switch and AC-On light • Temperature range: 0°C to 40°C (32°F to 104°F) • UL 924 Listed All Models • UV-stable thermoplastic housing • Compact, low-profile design • Easy to install • Long-life LED lamps • Bright, even illumination • Red and green letters • Universal single/double face • White finish • Push-in wiring connectors • Universal end/ceiling/wall mount • Universal snap-in, chevron arrows W NE Ordering Information CV 3 R E W -2C Series Options Housing Finish Faces 3 - Universal Single/Double Face W - White Letter Color Options Operation R - Red G - Green A - AC Only E - Emergency Options (Add -2C -DC suffix to model) Dimensions 7” 5 3/16” (17.8 cm) (13.2 cm) (Add suffix to model) 2-circuit operation (1)(3) Remote DC operation (1)(2)(3) (1) For use with AC models only. (2) For emergency illumination of sign from remote 6-24 VDC power sources. eparately (3) -2C and -DC options may not be specified rder together. Accessories (O Accessories (Order Separately) PMLXW WGLX WG-MLT WGLXC WGLXE VRS3 S ) Pendant mounting kit (white) Wire guard (Wall mount) Wire guard (Wall mount) Wire guard (Ceiling mount) Wire guard (End mount) Vandal resistant shield 9 3/4” (24.8 cm) 9” (22.8 cm) Power Consumption 13” (33.0 cm) 1 3/4” (4.4 cm) 120VAC 277VAC Red AC Only Models 2.7 watts 2.7 watts Green AC Only Models 2.3 watts 2.3 watts Red Emergency Models 3.8 watts 3.8 watts Green Emergency Models 3.5 watts 3.5 watts Power factor, average: .8 (lagging) 71 CVT Thermoplastic Tandem Unit Features • Factory assembled emergency unit/LED exit sign • UV-stable thermoplastic housing • High-output lighting heads • White finish • Damp location listed models available • 120/277VAC, 60 Hz operation • Solid-state charger with lowvoltage disconnect • Maintenance-free battery • Test switch and LED AC-On light W NE • Long-life LED lamps • Bright, even illumination • Universal single/double face • Red and green letter models • Snap-in, chevron arrows • Ceiling or wall mounting • Temperature range: 20°C to 30°C (68°F to 86°F) Damp location models: 10°C to 40°C (50°F to 104°F) • UL 924 Listed Ordering Information CVT 3 R W 5 D Series Faces 3 - Universal Single or Double Blank - Standard model - Damp location model* D * Only available on 3-head models W - White Letter Color Remote Heads R - Red G - Green Blank - No remote capability - Operates one additional 3 5.4 watt remote head 5 - Operates up to three additional 5.4 watt remote heads Options Input Amps Input Watts Application Housing Finish (Add suffix to model) 120VAC 277VAC .05 .02 5.0 5.0 Accessories (Order Separately) SRHSW0605 Matching remote head - single (white) SRHDW0605 Matching remote head - twin (white) ccessories (Order Separately) OMSSB0605 Single outdoor lighting head (black) OMSDB0605 Twin outdoor lighting head (black) PMLZTW Pendant mounting kit (white) (a) WGTW Wire guard (Wall mount) WGTCE Wire guard (Ceiling mount) A (a) Not available for use with 5-head models Dimensions 15 7/8”-Min. 19 3/4”-Max. 4 3/4”-Min. 6 3/4”-Max. (40.3 cm)-Min. (50.2 cm)-Max. (12.1 cm)-Min. (17.1 cm)-Max. Photometrics Horizontal Isofootcandle Distribution 6 Volt, 5.4 Watt SBT Lamp 14 3/8” (36.5 cm) 9” (22.8 cm) 13” (33.0 cm) 1 3/4” (4.4 cm) 72 CVD Cast Aluminum LED Exit Sign Features AC Models • All diecast aluminum construction • Soft edges and corners • White and black with brushed face finishes • Break-out directional chevrons • Universal mounting KO pattern • Back/ceiling/end mounting • Dual voltage – 120/277VAC • Bright and even illumination • Long-life LED lamps Emergency Models • Long life NiCad battery • 90 minute emergency operation • Test switch and AC-On indicator • Reverse polarity, short circuit and brownout protection • Thermally compensated charger • AC lockout • Temperature range: 20°C to 30°C (68°F to 86°F) • UL 924 Listed W NE Ordering Information CVD 1 R Series A BN -2C Options Operation A - AC Only E - Emergency Faces 1 - Single 2 - Double -DC -2C Letter Color (Add suffix to model) Remote DC operation (1) 2-circuit operation (1) (1) For use with AC models only. Housing Finish W - White BN - Black with brushed face R - Red G - Green Options Accessories (Order Separately) 121/2” Options (Add suffix to model) PMCW Pendant mounting kit (white) PMCB 121/2” Pendant mounting kit (black) WGLX Wire guard (Wall mount) WG-MLT Wire guard (Wall mount) ccessories (Order WGLXC Wire guard (Ceiling mount) Separately) WGLXE Wire guard (End mount) A Dimensions Power Consumption 9 1/8” (23 cm) 10” (25.5 cm) 11 3/4” (30 cm) 12 5/8” (32 cm) 1 5/8” (4.14 cm) Red AC Only Models: Green AC Only Models: Red Emergency Models: Green Emergency Models: 120VAC 2.6 watts 2.1 watts 3.8 watts 3.5 watts 277VAC 2.6 watts 2.1 watts 3.8 watts 3.5 watts *Wattage figures include LED lamps, transformer and electronics power requirements. LED lamp assemblies (red or green) consume less than 1 watt. Power factor, average: .8 (lagging) 73 CVER Recessed Mount Edge-Lit LED Exit Sign Features AC Models • Ceiling mounted models for recessed installation • Metal construction • Available in two color finishes • Clear acrylic plaque • Red and green letter models • Applique chevron arrows • Long life LED lamps • Bright, even letter illumination • Energy-saving operation W NE Ordering Information CVER 1 R N • Easy to install • 120/277VAC, 60 Hz operation Emergency Models • Fully automatic charger • Maintenance-free NiCad battery • Low voltage disconnect • Test switch and AC-On light • Temperature range: 20°C to 30°C (68°F to 86°F) • ETL Listed Availability To Be Announced E Operation Series A - AC only E - Emergency CVER - Recessed mount Faces 1 - Single 2 - Double* * Provided standard with mirror background. Fully-adjustable universal mounting bar system allows installations in standard construction and suspended ceiling applications. Trim/Housing Finish Letter Color N - Satin aluminum W - White R - Red G - Green Options (Add suffix to model) Accessories (Order Separately) Dimensions D E F Field installable chevrons provide for all possible directional arrow requirements. Power Consumption Red AC Only Models Green AC Only Models Red Emergency Models Green Emergency Models 120VAC 2.2W 2.5W 3.3W 3.6W 277VAC 3.7W 4.4W 4.7W 5.2W * Wattage figures include LED lamps, transformers and electronics power requirements. 74 A C A 7 7/8” B 11” C 12 5/8” D 15” E 14 3/8” F 4 1/8” 20.0 cm 27.9 cm 32.1 cm 38.1 cm 36.5 cm 10.5 cm B Features Ordering Information Options (Add suffix to model) Accessories (Order Separately) Remote Heads and Fixtures . ..........................................................76 to 78 Lamp Selector Guide .......................................................................................... 79 Voltage Drop Tables ................................................................................ 80 Unit Accessories . ................................................................................................. 81 National Electric Code ................................................................................. 82, 83 NFPA 101 Life Safety Code . ....................................................................... 84, 85 Limited Warranty ................................................................................................ 86 75 Remote Heads and Fixtures Standard Remote Lighting Heads SRH Series Injection molded thermoplastic lamphead/round mounting plate assemblies. Mounts to 31/2” octagonal or single gang boxes. For use with most commercial or industrial emergency fixtures. Standard finish is available in white or black. Single and twin lamp fixtures with a choice of incandescent or halogen PAR 36 lamps. Lamp photometrics and IES files available on the web at www.dual-lite.com White Black Halogen PAR 36 Incandescent PAR 36 Sealed Beam Sealed Beam Single Head With Twin Head With Single Head With Twin Head With Lamp Lamp Lamp Mounting Plate Mounting Plate Mounting Plate Mounting Plate Voltage Wattage Part No. SRHSW0605 SRHDW0605 SRHSB0605 SRHDB0605 6 5.4 0110258* SRHSW0607 SRHDW0607 SRHSB0607 SRHDB0607 6 7.2 0110213* SRHSW0618 SRHDW0618 SRHSB0618 SRHDB0618 6 18 0110127 SRHSW0625 SRHDW0625 SRHSB0625 SRHDB0625 6 25 0110041 SRHSW1207 SRHDW1207 SRHSB1207 SRHDB1207 12 7.2 0110289* SRHSW1218 SRHDW1218 SRHSB1218 SRHDB1218 12 18 0110128 SRHSW1225 SRHDW1225 SRHSB1225 SRHDB1225 12 25 0110132 SRHSW1235 SRHDW1235 SRHSB1235 SRHDB1235 12 35 0110233 SRHSW2409 SRHDW2409 SRHSB2409 SRHDB2409 24 9 0110230* SRHSW0608 SRHDW0608 SRHSB0608 SRHDB0608 6 8 0110162 SRHSW0612 SRHDW0612 SRHSB0612 SRHDB0612 6 12 0110159 SRHSW0620 SRHDW0620 SRHSB0620 SRHDB0620 6 20 0110157 SRHSW1208 SRHDW1208 SRHSB1208 SRHDB1208 12 8 0110189 SRHSW1212 SRHDW1212 SRHSB1212 SRHDB1212 12 12 0110190 * Sealed Beam type lamp Outdoor Remote Lighting Heads OMS Series Outdoor aluminum spot with sealed lamp and swivel assembly. Furnished with round gasketed aluminum mounting plate. Mounts to 31⁄ 2” octagonal boxes. Lamp photometrics and IES files available on the web at www.dual-lite.com White Black Halogen PAR 36 Incandescent PAR 36 Sealed Beam Sealed Beam Single Head With Twin Head With Single Head With Twin Head With Lamp Lamp Lamp Mounting Plate Mounting Plate Mounting Plate Mounting Plate OMSSW0605 OMSDW0605 OMSSB0605 OMSDB0605 6 5.4 0110258* OMSSW0607 OMSDW0607 OMSSB0607 OMSDB0607 6 7.2 0110213* OMSSW0618 OMSDW0618 OMSSB0618 OMSDB0618 6 18 0110127 OMSSW0625 OMSDW0625 OMSSB0625 OMSDB0625 6 25 0110041 OMSSW1207 OMSDW1207 OMSSB1207 OMSDB1207 12 7.2 0110289* OMSSW1218 OMSDW1218 OMSSB1218 OMSDB1218 12 18 0110128 OMSSW1225 OMSDW1225 OMSSB1225 OMSDB1225 12 25 0110132 OMSSW1235 OMSDW1235 OMSSB1235 OMSDB1235 12 35 0110233 OMSSW0608 OMSDW0608 OMSSB0608 OMSDB0608 6 8 0110162 OMSSW0612 OMSDW0612 OMSSB0612 OMSDB0612 6 12 0110159 OMSSW0620 OMSDW0620 OMSSB0620 OMSDB0620 6 20 0110157 OMSSW1208 OMSDW1208 OMSSB1208 OMSDB1208 12 8 0110189 OMSSW1212 OMSDW1212 OMSSB1212 OMSDB1212 12 12 0110190 * Sealed Beam type lamp 76 Voltage Wattage Part No. All Metal Remote Lighting Heads Remote Heads and Fixtures AHD Stamped aluminum housing with metal swivel. Standard finish available in white or black. Choice of incandescent or halogen PAR 36 lamps. Lamp photometrics and IES files available on the web at www.dual-lite.com White Black Single Head With Twin Head With Single Head With Twin Head With Lamp Lamp Lamp Halogen PAR 36 Sealed Beam Incandescent PAR 36 Sealed Beam Mounting Plate Mounting Plate Mounting Plate Mounting Plate Voltage Wattage Part No. AHDSW0605 AHDDW0605 AHDSB0605 AHDDB0605 6 5.4 0110258* AHDSW0607 AHDDW0607 AHDSB0607 AHDDB0607 6 7.2 0110213* AHDSW0618 AHDDW0618 AHDSB0618 AHDDB0618 6 18 0110127 AHDSW0625 AHDDW0625 AHDSB0625 AHDDB0625 6 25 0110041 AHDSW1207 AHDDW1207 AHDSB1207 AHDDB1207 12 7.2 0110289* AHDSW1218 AHDDW1218 AHDSB1218 AHDDB1218 12 18 0110128 AHDSW1225 AHDDW1225 AHDSB1225 AHDDB1225 12 25 0110132 AHDSW1235 AHDDW1235 AHDSB1235 AHDDB1235 12 35 0110233 AHDSW2407 AHDDW2407 AHDSB2407 AHDDB2407 24 7.2 0110212* AHDSW2413 AHDDW2413 AHDSB2413 AHDDB2413 24 13 0110009* AHDSW2418 AHDDW2418 AHDSB2418 AHDDB2418 24 18 0110010* AHDSW2428 AHDDW2428 AHDSB2428 AHDDB2428 24 28 0110011* AHDSWLV30 AHDDWLV30 AHDSBLV30 AHDDBLV30 120 30 0110021* AHDSW0608 AHDDW0608 AHDSB0608 AHDDB0608 6 8 0110162 AHDSW0612 (1) AHDDW0612 (1) AHDSB0612 AHDDB0612 6 12 0110159 AHDSW0620 AHDDW0620 AHDSB0620 AHDDB0620 6 20 0110157 AHDSW1208 AHDDW1208 AHDSB1208 AHDDB1208 12 8 0110189 AHDSB1212 AHDDB1212 12 12 0110190 (1) AHDSW1212 (1) AHDDW1212 * Sealed Beam type lamp (1) Matches LM City of Chicago models. Lamp photometrics and IES files available on the web at www.dual-lite.com GNX Series Moisture resistant thermoplastic head in black finish with coated lamp terminals and sealed swivel assembly. Furnished with mounting plate. Available with a choice of incandescent or halogen PAR 36 lamps. Matches N4X series units. Available with shatter containment option. Add “-L” to model number for Sealed Beam Lamps PAR36 only. Example: GNXSB0625-L N4X Remote Head Models Lamp Lamp Lamp Single Twin Volts Watts Part No. GNXSB0605 GNXDB0605 6 5.4 0110258* GNXSB0607 GNXDB0607 6 7.2 0110213* GNXSB0618 GNXDB0618 6 18 0110127 GNXSB0625 GNXDB0625 6 25 0110041 GNXSB1209 GNXDB1209 12 9 0110202* GNXSB1218 GNXDB1218 12 18 0110128 GNXSB1225 GNXDB1225 12 25 0110132 GNXSB1235 GNXDB1235 12 35 0110233 GNXSB0608 GNXDB0608 6 8 0110162 GNXSB0612 GNXDB0612 6 12 0110159 GNXSB0620 GNXDB0620 6 20 0110157 GNXSB1208 GNXDB1208 12 8 0110189 GNXSB1212 GNXDB1212 12 12 0110190 Halogen PAR 36 Incandescent PAR 36 Sealed Beam Sealed Beam Environmental Lighting Head * Sealed Beam Type lamp 77 Remote Heads and Fixtures RERS Injection molded housing. Surface mounted. Semi-recessed or recessed mounting available with kit. Black box, white trim. Single (RERS-1) and twin (RERS-2) lamp models. Dimensions and mounting kits same as Lite2. Square Catalog No. Recessed Rectangle Catalog No. Recessed Eyeball Lamp Part No. 124R-0628 124R-1228 0110003 0110007 Lamp Part No. RERS-1-0609 0110163 RERS-2-0607 0110213 F-SRM Semi-recessed mounting kit -FRM 124R Recessed mounted fixture with frosted lens. White trim. Dimensions: 83⁄16” x 41⁄2” x 4”. Gimbal Fully-recessed option 133 Adjustable to 42° and rotated through 358°. White standard, other finishes upon request. Dimensions: Trim ring: 47⁄ 8” dia. Back box: 43⁄ 16” deep x 4” dia. Catalog No. 133-0618 133-1218 122 Adjustable (60° max.) recessed mounted fixture. Matte white trim. Dimensions: 81⁄ 2” dia. x 41⁄ 2”. Incandescent PAR 36 Lamp Models Catalog No. Lamp Part no. 122SB-0625 122SB-1225 0110041 0110132 Halogen PAR 36 Lamp Models Catalog No Lamp Part No. 122SB-T-0608 122SB-T-0612 122SB-T-0620 122SB-T-1208 122SB-T-1212 Lamp Part No. 0110002 0110006 0110162 0110159 0110157 0110189 0110190 Bayonet Base Lamp Models Catalog No. Lamp Part No. 122-2407 122-2413 122-2418 122-2428 LZ Series Matching Remote Lighting Heads 0110212 0110009 0110010 0110011 Single Remote Single Remote Lamp Lamp Lamp LZR Head -White Architectural/commercial design. High performance MR-16 halogen lamps standard. Mounts to standard electrical boxes using universal mounting plate provided. Fixture housing mounts to back plate in a choice of four mounting positions. Housings secured using locking screws provided. Head - Black Volts Watts Part No. LZRSW0605 LZRSB0605 6 5 0110256 LZRSW0610 LZRSB0610 6 10 0110261 LZRSW1205 LZRSB1205 12 5 0110263 LZRSW1210 LZRSB1210 12 10 0110264 Twin Remote Twin Remote Lamp Lamp Lamp Head -White Head - Black Volts Watts Part No. LZRDW0605 LZRDB0605 6 5 0110256 LZRDW0610 LZRDB0610 6 10 0110261 LZRDW1205 LZRDB1205 12 5 0110263 LZRDW1210 LZRDB1210 12 10 0110264 Lamp photometrics and IES files available on the web at www.dual-lite.com IPS Series Matching Remote Lighting Heads C1D2R/C1D2TR Suitable for wet and damp location applications. Rated for NEC Class I, Division 2, Groups B, C and D as well as Class I, Zone 2, Group IIB + H2 environments. Black housing and head assemblies. Single (C1D2R) and twin (C1D2TR) head models. Model Numbers Lamps * Single Head Twin Head Volts Watts Hub Left Side(1)(2) Hub Left Side(1)(2) 6 8 C1D2R-6V8W C1D2TR-6V8W 6 12 C1D2R-6V12W C1D2TR-6V12W 12 8 C1D2R-12V8W C1D2TR-12V8W 12 12 C1D2R-12V12W C1D2TR-12V12W 3R Listed * PAR 36 Halogen sealed beam lamps. (1) Hub Right Side - add “R” to end of model number. Example C1D2R-6V8WR. (2) Hubs Both Sides - add “F” to end of model number. Example C1D2R- Consult factory for additional voltage and wattage configurations for remote fixtures. 78 Lamp Selector Guide MR16 Lamps Dual-Lite Part Number Lamp Number Lamp Type Lamp Volts Lamp Watts 0110256 MR16 6V5W Halogen 6 5 0110261 MR16 6V10W Halogen 6 10 0110263 MR16 12V5W Halogen 12 5 0110264 MR16 12V10W Halogen 12 10 PAR 36 Sealed Beam Lamps Dual-Lite Part Number Lamp Number Lamp Type Lamp Volts Lamp Watts 0110127 4014 Incandescent 6 18 Incandescent 6 25 0110041 4510 Incandescent 12 18 0110128 4414 0110132 4446 Incandescent 12 25 0110233 4411 Incandescent 12 35 Halogen 6 8 0110162 H7551 Halogen 6 12 0110159 H7553 Halogen 6 20 0110157 H7554 0110189 H7555 Halogen 12 8 0110190 H7557 Halogen 12 12 Double Contact Bayonet Base Lamps Dual-Lite Part Number Lamp Number Lamp Type Lamp Volts Lamp Watts 0110212 304 Incandescent 24 7.2 0110009 1692 Incandescent 24 13 0110010 308 Incandescent 24 18 0110011 310 Incandescent 24 28 0110021 30S11/93 Incandescent 125 30 Wedge Base Lamps Dual-Lite Part Number Lamp Number Lamp Type Lamp Volts Lamp Watts 0110258 939 Incandescent 6 5.4 0110213 927 Incandescent 6 7.2 KB-AN Incandescent 12 7.2 0110289 915 Incandescent 12 9 0110202 0110230 - Incandescent 24 9 79 Voltage Drop Tables The National Electrical Code limits voltage drop to a maximum of 5% of nominal. Circuit runs must be of sufficient capacity to maintain operating voltage when remote fixtures and/or exit signs are connected to the emergency lighting TABLE A - Important Electrical Installation Information 12 Volt System 6 Volt System Wire Gauge Wire Gauge Total Watts #12 #10 #8 #6 Total Watts #12 #10 #8 on Wire Run Max. Length of Wire Run (Feet) on Wire Run Max. Length of Wire Run (Feet) #6 379 325 284 227 178 162 134 119 114 108 95 86 76 63 53 44 43 29 21 17 14 12 10 10 9 6 7 8 10 12 14 16 18 20 21 24 25 30 35 40 48 50 75 100 125 150 175 200 225 250 378 324 283 226 178 162 133 119 113 108 89 86 75 65 53 44 43 28 21 17 14 12 10 10 9 600 515 450 360 283 257 212 189 180 171 141 136 120 103 85 70 68 45 34 27 23 19 16 16 14 955 818 716 570 450 409 338 300 286 273 225 216 190 164 135 112 108 72 54 43 36 31 27 25 22 1518 1301 1138 910 715 650 538 477 455 434 357 344 303 260 214 178 172 115 86 69 57 49 42 40 36 6 7 8 10 12 14 16 18 20 21 24 25 30 35 40 48 50 75 100 125 150 175 200 225 250 94 81 70 56 44 40 33 30 28 27 24 21 19 15 13 11 11 7 5 4 3 3 2 2 2 150 129 112 90 70 64 53 47 45 43 38 34 30 25 21 17 17 11 8 7 5 5 4 4 3 238 204 179 143 112 102 84 75 71 68 60 54 48 39 33 28 27 18 14 11 9 8 6 6 5 Values not shown in Table A may be calculated using the following formulas: Length (Feet) = I. Maximum Example: Table B Constant Value Maximum Load (Watts) Find the maximum circuit length for #8 wire on a 24 volt system with an 80 watt load. Maximum Length (Feet) = 21613 ÷ 80 = 270 feet. Table B Constant Value II. Maximum Load (Watts) = Maximum Length (Feet) Example: Find the maximum circuit load for 540 feet of #12 wire on a 32 volt system. Maximum Load (Watts) = 15197 ÷ 540 = 28 watts. Table B Constant Values per Voltage System Wire Size (Maximum Voltage Drop 5%) System Wire Size #12 Constant 534 System Wire Size #12 Constant 6 Volt #10 #8 849 #10 #6 350 #12 #10 #8 2148 32 Volt #8 #6 2137 #4 #12 3397 #10 5403 48 Volt #8 #6 12 Volt #4 8590 #6 13660 #4 #12 #12 #10 #8 8548 #10 13588 #6 21613 110 Volt #8 #6 24 Volt #4 34363 54641 #4 #2 15197 24157 38423 61090 97140 34193 54353 86452 137454 218565 179575 285450 454025 721875 1147850 1824900 Uniform Loads The maximum circuit length data in Table A (and derived from Table B) assumes that 100% of the load is concentrated at the end of the run. If equally sized loads can be equally spaced along the run, maximum circuit length can be increased by the multipliers shown in Table C. Table C Multipliers for Equally Sized, Equally Spaced Loads (Maximum Voltage Drop 5%) Number of Fixtures Multiply Distance By 80 2 3 4 5 6 7 8 9 10 n 1.333 1.500 1.600 1.670 1.714 1.750 1.777 1.800 1.818 2n/(n+1) Unit Accessories Wire Guards Mounting Brackets and Shelves Offered for most Dual-Lite emergency lights and exits. Constructed of heavy gauge steel, all wire guards are standard with chrome plating. Order as separate line item. For mounting of AS Series industrial emergency lighting units. WB-6 6000 L-6 & L-12-S mounting BrACkets And sHelVes Wire guArds CAt. no. WGLZ S6WG WGEL 40G 41G WGLX WGLXC WGLXE WGTW WGTCE WG-MLT CAt. no. WB-6 6000 L-6 L-12-S for use WitH All enclosure 1 & 2 models Enclosure 1 models only Enclosure 1 models only Enclosure 2 models only type Bracket Shelf Shelf Shelf dimensions -11” H x 14” L x 81⁄8” D 11” H x 14” L x 81⁄8” D 11” H x 16” L x 81⁄8” D for use WitH LZ Series (except High-Capacity models) Remote heads EZ-2, EZ-2R and LZ High-Capacity Series, Remote heads, CV Series dimensions (inside) 61⁄4” H x 14” L x 41⁄4” D 8” H x 8” L x 8” D 8” H x 20” L x 8” D LM Series with top mounted heads, AS Series (enclosure 1 models), N4X Series, CVEC Series (15 and 30 watt models) and NYXC tandem units 181⁄2” H x 20” L x 12” D AS Series (enclosure 2 models), Delite Cylinder Series, SMC exits and CVEC Series (50 and 100 watt models) EXT-122-EM-K, Wall mount LX, LED and Sempra Series exits, Wall Mount CV3 Series Ceiling mount LX, LED, Sempra and CV3 Series exits 21” H x 23” L x 15” D Vandal Resistant Shields 10” H x 14” L x 21⁄4” D For protection against vandalism or accidental damage. Prevents tampering with mountings and lamps. End mount LX, LED and Sempra, CV3 and CVD Series exits Wall mount LT, Freedom LED, CVT NYDC and NYX Series exits 101⁄ 2” H x 141⁄ 2” L x 31⁄ 2” D Ceiling or end mount LT, CVD, CVT and Freedom LED Series exits. Ceiling mount NYDC and NYX Series exits Lite2 Series, Wall mount LX, DK, Sempra DEX, CV3 and CVD Series exits 20” H x 167⁄ 8” L x 8” D 101⁄4” H x 133⁄4” L x 31⁄ 2” D 16” H x 20” L x 77⁄ 8” D 115⁄ 8” H x 135⁄ 8” L x 7” D VRS/VRS-4X VRS2 VRS3 VAndAl sHields CAt. no. for use WitH VRS EZ-2, LZ, LZ High Capacity, EXT-122-EM-K, VRS-4X* EZ-2R Series and CV Series VRS2 Lite2 Series, LT Series exits VRS3 LX, DK, Sempra and CV3 Series exits * VRS-4X supplied with a neoprene wall gasket dimensions (outside) 20” L x 101⁄ 2” H x 7 3⁄ 4” D 211⁄ 4” L x 19 3⁄ 4” H x 6 1⁄ 4” D 15 1⁄ 2” L x 111⁄ 2” H x 4 1⁄ 2” D 81 National Electric Code NEC (NFPA 70) - 2005 I. General 700.1 Scope. The provisions of this article apply to the electrical safety of the installation, operation, and maintenance of emergency systems consisting of circuits and equipment intended to supply, distribute, and control electricity for illumination, power, or both, to required facilities when the normal electrical supply or system is interrupted. Emergency systems are those systems legally required and classed as emergency by municipal, state, federal, or other codes, or by any governmental agency having jurisdiction. These systems are intended to automatically supply illumination, power, or both, to designated areas and equipment in the event of failure of the normal supply or in the event of accident to elements of a system intended to supply, distribute, and control power and illumination essential for safety to human life. FPN No. 1: For further information regarding wiring and installation of emergency systems in health care facilities, see Article 517. FPN No. 2: For further information regarding performance and maintenance of emergency systems in health care facilities, see NFPA 99-2002, Standard for Health Care Facilities. FPN No. 3: Emergency systems are generally installed in places of assembly where artificial illumination is required for safe exiting and for panic control in buildings subject to occupancy by large numbers of persons, such as hotels, theaters, sports arenas, health care facilities, and similar institutions. Emergency systems may also provide power for such functions as ventilation where essential to maintain life, fire detection and alarm systems, elevators, fire pumps, public safety communications systems, industrial processes where current interruption would produce serious life safety or health hazards, and similar functions. FPN No. 4: For specification of locations where emergency lighting is considered essential to life safety, see NFPA 101®-2003, Life Safety Code®. FPN No. 5: For further information regarding performance of emergency and standby power systems, see NFPA 110®- 2002, Standard for Emergency and Standby Power Systems. 700.2 Application of Other Articles. Except as modified by this article, all applicable articles of this Code shall apply. 700.3 Equipment Approval. All equipment shall be approved for use on emergency systems. 700.4 Tests and Maintenance. (A) Conduct or Witness Test. The authority having jurisdiction shall conduct or witness a test of the complete system upon installation and periodically afterward. (B) Tested Periodically. Systems shall be tested periodically on a schedule acceptable to the authority having jurisdiction to ensure the systems are maintained in proper operating condition. (C) Battery Systems Maintenance. Where battery systems or unit equipments are involved, including batteries used for starting, control, or ignition in auxiliary engines, the authority having jurisdiction shall require periodic maintenance. (D) Written Record. A written record shall be kept of such tests and maintenance. (E) Testing Under Load. Means for testing all emergency lighting and power systems during maximum anticipated load conditions shall be provided. FPN: For testing and maintenance procedures of emergency power supply systems (EPSSs), see NFPA 110-2002, Standard for Emergency and Standby Power Systems. 700.5 Capacity. (A) Capacity and Rating. An emergency system shall have adequate capacity and rating for all loads to be operated simultaneously. The emergency system equipment shall be suitable for the maximum available fault current at its terminals. (B) Selective Load Pickup, Load Shedding, and Peak Load Shaving. The alternate power source shall be permitted to supply emergency, legally required standby, and optional standby system loads where the source has adequate capacity or where automatic selective load pickup and load shedding is provided as needed to ensure adequate power to (1) the emergency circuits, (2) the legally required standby circuits, and (3) the optional standby circuits, in that order of priority. The alternate power source shall be permitted to be used for peak load shaving, provided these conditions are met. Peak load-shaving operation shall be permitted for satisfying the test requirement of 700.4(B), provided all other conditions of 700.4 are met. A portable or temporary alternate source shall be available whenever the emergency generator is out of service for major maintenance or repair. 700.6 Transfer Equipment. (A) General. Transfer equipment, including automatic transfer switches, shall be automatic, identified for emergency use, and approved by the authority having jurisdiction. Transfer equipment shall be designed and installed to prevent the inadvertent interconnection of normal and emergency sources of supply in any operation of the transfer equipment. Transfer equipment and electric power production systems installed to permit operation in parallel with the normal source shall meet the requirements of Article 705. (B) Bypass Isolation Switches. Means shall be permitted to bypass and isolate the transfer equipment. Where bypass isolation switches are used, inadvertent parallel operation shall be avoided. (C) Automatic Transfer Switches. Automatic transfer switches shall be electrically operated and mechanically held. (D) Use. Transfer equipment shall supply only emergency loads. 700.7 Signals. Audible and visual signal devices shall be provided, where practicable, for the purpose described in 700.7(A) through 700.7(D). (A) Derangement. To indicate derangement of the emergency source. (B) Carrying Load. To indicate that the battery is carrying load. (C) Not Functioning. To indicate that the battery charger is not functioning. (D) Ground Fault. To indicate a ground fault in solidly grounded wye emergency 82 systems of more than 150 volts to ground and circuit-protective devices rated 1000 amperes or more. The sensor for the ground-fault signal dewwwvices shall be located at, or ahead of, the main system disconnecting means for the emergency source, and the maximum setting of the signal devices shall be for a ground-fault current of 1200 amperes. Instructions on the course of action to be taken in event of indicated ground fault shall be located at or near the sensor location. FPN: For signals for generator sets, see NFPA 110-2002,Standard for Emergency and Standby Power Systems. 700.8 Signs. (A) Emergency Sources. A sign shall be placed at the service entrance equipment, indicating type and location of on-site emergency power sources. Exception: A sign shall not be required for individual unit equipment as specified in 700.12(F). (B) Grounding. Where the grounded circuit conductor connected to the emergency source is connected to a grounding electrode conductor at a location remote from the emergency source, there shall be a sign at the grounding location that shall identify all emergency and normal sources connected at that location. II. Circuit Wiring 700.9 Wiring, Emergency System. (A) Identification. All boxes and enclosures (including transfer switches, generators, and power panels) for emergency circuits shall be permanently marked so they will be readily identified as a component of an emergency circuit or system. (B) Wiring. Wiring of two or more emergency circuits supplied from the same source shall be permitted in the same raceway, cable, box, or cabinet. Wiring from an emergency source or emergency source distribution overcurrent protection to emergency loads shall be kept entirely independent of all other wiring and equipment, unless otherwise permitted in (1) through (4): (1) Wiring from the normal power source located in transfer equipment enclosures (2) Wiring supplied from two sources in exit or emergency luminaires (lighting fixtures) (3) Wiring from two sources in a common junction box, attached to exit or emergency luminaires (lighting fixtures) (4) Wiring within a common junction box attached to unit equipment, containing only the branch circuit supplying the unit equipment and the emergency circuit supplied by the unit equipment (C) Wiring Design and Location. Emergency wiring circuits shall be designed and located so as to minimize the hazards that might cause failure due to flooding, fire, icing, vandalism, and other adverse conditions. (D) Fire Protection. Emergency systems shall meet the additional requirements in 700.9(D)(l) and (D)(2) assembly occupancies for not less than 1000 persons or in buildings above 23 m (75 ft) in height with any of the following occupancy classes: assembly, educational, residential, detention and correctional, business, and mercantile. (1) Feeder-Circuit Wiring. Feeder-circuit wiring shall meet one of the following conditions: (1) Be installed in spaces or areas that are fully protected by an approved automatic fire suppression system (2) Be a listed electrical circuit protective system with a minimum l-hour fire rating (3) Be protected by a listed thermal barrier system for electrical system components (4) Be protected by a fire-rated assembly listed to achieve a minimum fire rating of 1 hour (5) Be embedded in not less than 50 mm (2 in.) of concrete (6) Be a cable listed to maintain circuit integrity for not less than 1 hour when installed in accordance with the listing requirements (2) Feeder-Circuit Equipment. Equipment for feeder circuits (including transfer switches, transformers, and panel boards) shall be located either in spaces fully protected by approved automatic fire suppression systems (including sprinklers, carbon dioxide systems) or in spaces with a 1-hour fire resistance rating. FPN: For the definition of occupancy classification, see Section 6.1 of NFPA 1012003, Life Safety Code. III. Sources of Power 700.12 General Requirements. Current supply shall be such that, in the event of failure of the normal supply to, or within, the building or group of buildings concerned, emergency lighting, emergency power, or both shall be available within the time required for the application but not to exceed 10 seconds. The supply system for emergency purposes, in addition to the normal services to the building and meeting the general requirements of this section, shall be one or more of the types of systems described in 700.12(A) through 700.12(E). Unit equipment in accordance with 700.12(F) shall satisfy the applicable requirements of this article. In selecting an emergency source of power, consideration shall be given to the occupancy and the type of service to be rendered, whether of minimum duration, as for evacuation of a theater, or longer duration, as for supplying emergency power and lighting due to an indefinite period of current failure from trouble either inside or outside the building. Equipment shall be designed and located so as to minimize the hazards that might cause complete failure due to flooding, fires, icing, and vandalism. Equipment for sources of power as described in 700.12(A) through 700.12(E) where located within assembly occupancies for greater than 1000 persons or in buildings above 23 m (75 ft) in height with any of the following occupancy classes — assembly, educational, residential, detention and correctional, business, and mercantile — shall be installed either in spaces fully protected by approved automatic fire suppression systems (sprinklers, carbon dioxide systems, and so forth) or in spaces with a 1-hour fire rating. National Electric Code NEC (NFPA 70) - 2005 FPN No. 1: For the definition of occupancy classification, see Section 6.1 of NFPA 101-2003, Life Safety Code. FPN No. 2: Assignment of degree of reliability of the recognized emergency supply system depends on the careful evaluation of the variables at each particular installation. (A) Storage Battery. Storage batteries used as a source of power for emergency systems shall be of suitable rating and capacity to supply and maintain the total load for a minimum period of 1 1/2 hours, without the voltage applied to the load falling below 87-1/2 percent of normal. Batteries, whether of the acid or alkali type, shall be designed and constructed to meet the requirements of emergency service and shall be compatible with the charger for that particular installation. For a sealed battery, the container shall not be required to be transparent. However, for the lead acid battery that requires water additions, transparent or translucent jars shall be furnished. Automotive-type batteries shall not be used. An automatic battery charging means shall be provided. (B) Generator Set. (1) Prime Mover-Driven. For a generator set driven by a prime mover acceptable to the authority having jurisdiction and sized in accordance with 700.5, means shall be provided for automatically starting the prime mover on failure of the normal service and for automatic transfer and operation of all required electrical circuits. A time-delay feature permitting a 15-minute setting shall be provided to avoid retransfer in case of short-time reestablishment of the normal source. (2) Internal Combustion as Prime Movers. Where internal combustion engines are used as the prime mover, an on-site fuel supply shall be provided with an onpremise fuel supply sufficient for not less than 2 hours’ full-demand operation of the system. Where power is needed for the operation of the fuel transfer pumps to deliver fuel to a generator set day tank, this pump shall be connected to the emergency power system. (3) Dual Supplies. Prime movers shall not be solely dependent on a public utility gas system for their fuel supply or municipal water supply for their cooling systems. Means shall be provided for automatically transferring from one fuel supply to another where dual fuel supplies are used. Exception: Where acceptable to the authority having jurisdiction, the use of other than on-site fuels shall be permitted where there is a low probability of a simultaneous failure of both the off-site fuel delivery system and power from the outside electrical utility company. (4) Battery Power and Dampers. Where a storage battery is used for control or signal power or as the means of starting the prime mover, it shall be suitable for the purpose and shall be equipped with an automatic charging means independent of the generator set. Where the battery charger is required for the operation of the generator set, it shall be connected to the emergency system. Where power is required for the operation of dampers used to ventilate the generator set, the dampers shall be connected to the emergency system. (5) Auxiliary Power Supply. Generator sets that require more than 10 seconds to develop power shall be permitted if an auxiliary power supply energizes the emergency system until the generator can pick up the load. (6) Outdoor Generator Sets. Where an outdoor housed generator set is equipped with a readily accessible disconnecting means located within sight of the building or structure supplied, an additional disconnecting means shall not be required where ungrounded conductors serve or pass through the building or structure. (C) Uninterruptible Power Supplies. Uninterruptible power supplies used to provide power for emergency systems shall comply with the applicable provisions of 700.12(A) and 700. 12(B) (D) Separate Service. Where acceptable to the authority having jurisdiction as suitable for use as an emergency source of power, an additional service shall be permitted. This service shall be in accordance with the applicable provisions of Article 230 and the following additional requirements: (1) Separate service drop or service lateral (2) Service conductors sufficiently remote electrically and physically from any other service conductors to minimize the possibility of simultaneous interruption of supply (E) Fuel Cell System. Fuel cell systems used as a source of power for emergency systems shall be of suitable rating and capacity to supply and maintain the total load for not less than 2 hours of full-demand operation. Installation of a fuel cell system shall meet the requirements of Parts II through VIII of Article 692. Where a single fuel cell system serves as the normal supply for the building or group of buildings concerned, it shall not serve as the sole source of power for the emergency standby system. (F) Unit Equipment. Individual unit equipment for emergency illumination shall consist of the following: (1) A rechargeable battery (2) A battery charging means (3) Provisions for one or more lamps mounted on the equipment, or shall be permitted to have terminals for remote lamps, or both (4) A relaying device arranged to energize the lamps automatically upon failure of the supply to the unit equipment The batteries shall be of suitable rating and capacity to supply and maintain at not less than 87-1/2 percent of the nominal battery voltage for the total lamp load associated with the unit for a period of at least l l/2 hours, or the unit equipment shall supply and maintain not less than 60 per cent of the initial emergency illumination for a period of at least 11/2 hours. Storage batteries, whether of the acid or alkali type, shall be designed and constructed to meet the requirements of emergency service. Unit equipment shall be permanently fixed in place (i.e., not portable) and shall have all wiring to each unit installed in accordance with the requirements of any of the wiring methods in Chapter 3. Flexible cord-and-plug connection shall be permitted, provided that the cord does not exceed 900 mm (3 ft) in length. The branch circuit feeding the unit equipment shall be the same branch circuit as that serving the normal lighting in the area and connected ahead of any local switches. The branch circuit that feeds unit equipment shall be clearly identified at the distribution panel. Emergency luminaires (illumination fixtures) that obtain power from a unit equipment and are not part of the unit equipment shall be wired to the unit equipment as required by 700.9 and by one of the wiring methods of Chapter 3. Exception: In a separate and uninterrupted area supplied by a minimum of three normal lighting circuits, a separate branch circuit for unit equipment shall be permitted if it originates from the same panelboard as that of the normal lighting circuits and is provided with a lock-on feature. IV. Emergency System Circuits for Lighting and Power 700.15 Loads on Emergency Branch Circuits. No appliances and no lamps, other than those specified as required for emergency use, shall be supplied by emergency lighting circuits. 700.16 Emergency Illumination. Emergency illumination shall include all required means of egress lighting, illuminated exit signs, and all other lights specified as necessary to provide required illumination. Emergency lighting systems shall be designed and installed so that the failure of any individual lighting element, such as the burning out of a light bulb, cannot leave in total darkness any space that requires emergency illumination. Where high-intensity discharge lighting such as high and low-pressure sodium, mercury vapor, and metal halide is used as the sole source of normal illumination, the emergency lighting system shall be required to operate until normal illumination has been restored. Exception: Alternative means that ensure emergency lighting illumination level is maintained shall be permitted. 700.17 Circuits for Emergency Lighting. Branch circuits that supply emergency lighting shall be installed to provide service from a source complying with 700.12 when the normal supply for lighting is interrupted. Such installations shall provide either of the following: (l) An emergency lighting supply, independent of the general lighting supply, with provisions for automatically transferring the emergency lights upon the event of failure of the general lighting system supply (2) Two or more separate and complete systems with independent power supply, each system providing sufficient current for emergency lighting purposes unless both systems are used for regular lighting purposes and are both kept lighted, means shall be provided for automatically energizing either system upon failure of the other. Either or both systems shall be permitted to be a part of the general lighting system of the protected occupancy if circuits supplying lights for emergency illumination are installed in accordance with other sections of this article. 700.18 Circuits for Emergency Power. For branch circuits that supply equipment classed as emergency, there shall be an emergency supply source to which the load will be transferred automatically upon the failure of the normal supply. V. Control—Emergency Lighting Circuits 700.20 Switch Requirements. The switch or switches installed in emergency lighting circuits shall be arranged so that only authorized persons have control of emergency lighting. Exception No. 1: Where two or more single-throw switches are connected in parallel to control a single circuit, at least one of these switches shall be accessible only to authorized persons. Exception No. 2: Additional switches that act only to put emergency lights into operation but not disconnect them shall be permissible. Switches connected in series or 3- and 4-way switches shall not be used. 700.21 Switch Location. All manual switches for controlling emergency circuits shall be in locations convenient to authorized persons responsible for their actuation. In facilities covered by Articles 518 and 520, a switch for controlling emergency lighting systems shall be located in the lobby or at a place conveniently accessible thereto. In no case shall a control switch for emergency lighting to be placed in a motion-picture projection booth or on a stage or platform. Exception: Where multiple switches are provided, one such switch shall be permitted in such locations where arranged so that it can only energize the circuit, but cannot de-energize the circuit. 700.22 Exterior Lights. Those lights on the exterior of a building that are not required for illumination when there is sufficient daylight shall be permitted to be controlled by an automatic light-actuated device. VI. Overcurrent Protection 700.25 Accessibility. The branch-circuit overcurrent devices in emergency circuits shall be accessible to authorized persons only. 700.26 Ground-Fault Protection of Equipment. The alternate source for emergency systems shall not be required to have ground-fault protection of equipment with automatic disconnecting means. Ground-fault indication of the emergency source shall be provided per 700.7(D). 700.27 Coordination. Emergency system(s) overcurrent devices shall be selectively coordinated with all supply side overcurrent protective devices. 83 National Fire Protection Assn. LIFE SAFETY CODE (NFPA 101) - 2003 Section 4.6 General Requirements 4.6.13 Maintenance and Testing. 4.6.13.1 Whenever or wherever any device, equipment, system, condition, arrangement, level of protection, or any other feature is required for compliance with the provisions of this Code, such device, equipment, system, condition, arrangement, level of protection, or other feature shall thereafter be continuously maintained in accordance with applicable NFPA requirements or as directed by the authority having jurisdiction. 4.6.13.2* Existing life safety features obvious to the public, if not required by the Code, shall be either maintained or removed. 4.6.13.3 Equipment requiring periodic testing or operation to ensure its maintenance shall be tested or operated as specified elsewhere in this Code or as directed by the authority having jurisdiction. 4.6.13.4 Maintenance and testing shall be performed under the supervision of a responsible person who shall ensure that testing and maintenance are made at specified intervals in accordance with applicable NFPA standards or as directed by the authority having jurisdiction. 7.8 Illumination of Means of Egress. 7.8.1 General 7.8.1.1* Illumination of means of egress shall be provided in accordance with Section 7.8 for every building and structure where required in Chapter 11 through Chapter 42. For the purposes of this requirement, exit access shall include only designated stairs, aisles, corridors, ramps, escalators, and passageways leading to an exit. For the purposes of this requirement, exit discharge shall include only designated stairs, aisles, corridors, ramps, escalators, walkways, and exit passage ways leading to a public way. 7.8.1.2 Illumination of means of egress shall be continuous during the time that the conditions of occupancy require that the means of egress be available for use, unless otherwise provided in 7.8.1.2.2. 7.8.1.2.1 Artificial lighting shall be employed at such locations and for such periods of time as are necessary to maintain the illumination to the minimum criteria values herein specified. 7.8.1.2.2 Automatic, motion sensor-type lighting switches shall be permitted within the means of egress, provided that the switch controllers are equipped for fail-safe operation, the illumination timers are set for a minimum 15-minute duration, and the motion sensor is activated by any occupant movement in the area served by the lighting units. 7.8.1.3* The floors and other walking surfaces within an exit and within the portions of the exit access and exit discharge designated in 7.8.1.1 shall be illuminated as follows: (1) During conditions of stair use, the minimum illumination for new stairs shall be at least 108 lux (10 ft-candle), measured at the walking surfaces. (2) The minimum illumination for floors and walking surfaces, other than new stairs, shall be to values of at least 10.8 lux (1 ft-candle), measured at the floor. (3) In assembly occupancies, the illumination of the floors of exit access shall be at least 2.2 lux (0.2 ft-candle) during periods of performances or projections involving directed light. (4) * The minimum illumination requirements shall not apply where operations or processes require low lighting levels. 7.8.1.4* Required illumination shall be arranged so that the failure of any single lighting unit does not result in an illumination level of less than 2.2 lux (0.2 ftcandle) in any designated area. 7.8.1.5 The equipment or units installed to meet the requirements of Section 7.10 also shall be permitted to serve the function of illumination of means of egress, provided that all requirements of Section 7.8 for such illumination are met. 7.8.2 Sources of Illumination. 7.8.2.1* Illumination of means of egress shall be from a source considered reliable by the authority having jurisdiction. 7.8.2.2 Battery-operated electric lights and other types of portable lamps or lanterns shall not be used for primary illumination of means of egress. Battery-operated electric lights shall be permitted to be used as an emergency source to the extent permitted under Section 7.9. 7.9.2 Performance of System. 7.9.2.1* Emergency illumination shall be provided for not less than 1 1/2 hours in the event of failure of normal lighting. Emergency lighting facilities shall be arranged to provide initial illumination that is not less than an average of 10.8 lux (1 ft-candle) and, at any point, not less than 1.1 lux (0.1 ft-candle), measured along the path of egress at floor level. Illumination levels shall be permitted to decline to not less than an average of 6.5 lux (0.6 ft candle) and, at any point, not less than 6.5 lux (0.06 ft-candle) at the end of the 1 1/2 hours. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. 7.9.2.2* The emergency lighting system shall be arranged to provide the required illumination automatically in the event of any interruption of normal lighting due to any of the following: (1) Failure of a public utility or other outside electrical power supply (2) Opening of a circuit breaker or fuse (3) Manual act(s), including accidental opening of a switch controlling normal lighting facilities 7.9.2.3 Emergency generators providing power to emergency lighting systems shall be installed, tested, and maintained in accordance with NFPA 110, Standard for Emergency and Standby Power Systems. Stored electrical energy systems, where required in this Code, shall be installed and tested in accordance with NFPA 111, Standard on Stored Electrical Energy Emergency and Standby Power Systems. 7.9.2.4* Battery-operated emergency lights shall use only reliable types of rechargeable batteries provided with suitable facilities for maintaining them in properly charged condition. Batteries used in such lights or units shall be approved for their intended use and shall comply with NFPA 70, National Electrical Code®. 7.9.2.5 The emergency lighting system shall be either continuously in operation or shall be capable of repeated automatic operation without manual intervention. 7.9.3 Periodic Testing of Emergency Lighting Equipment. 7.9.3.1 Required emergency lighting systems shall be tested in accordance with one of the three options offered by 7.9.3.1.1, 7.9.3.1.2, or 7.9.3.1.3. 7.9.3.1.1 Testing of required emergency lighting systems | shall be permitted to be conducted as follows: (1) Functional testing shall be conducted at 30-day intervals for not less than 30 seconds. (2) Functional testing shall be conducted annually for not less than 1 1/2 hours if the emergency lighting system is battery powered. (3) The emergency lighting equipment shall be fully operational for the duration of the tests required by 7.9.3.1.1 ( 1 ) and 7.9.3.1.1 (2). (4) Written records of visual inspections and tests shall be kept by the owner for inspection by the authority having jurisdiction. 7.9.3.1.2 Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall be provided. (2) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall automatically perform not less than once every 30 days a test for not less than 30 seconds and a diagnostic routine. (3) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall indicate failures by a status indicator. (4) A visual inspection shall be performed at intervals not exceeding 30 days. (5) Functional testing shall be conducted annually for not less than 1 1/2 hours. (6) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall be fully operational for the duration of the 1 1/2 hour test. (7) Written records of visual inspections and tests shall be kept by the owner for inspection by the authority having jurisdiction. 7.9.3.1.3 Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Computer-based, self-testing/self-diagnostic battery-operated emergency lighting equipment shall be provided. (2) The emergency lighting equipment shall automatically perform not less than once every 30 days a test for not less than 30 seconds and a diagnostic routine. (3) The emergency lighting equipment shall automatically perform annually a test for not less than 11/2 hours. (4) The emergency lighting equipment shall be fully operational for the duration of the tests required by 7.9.3.1.3(2) and 7.9.3.1.3(3). (5) The computer-based system shall be capable of providing a report of the history of tests and failures at all times. 7.9 Emergency Lighting. 7.9. 1 General. 7.9.1.1* Emergency lighting facilities for means of egress shall be provided in accordance with Section 7.9 for the following: (1) Buildings or structures where required in Chapter 11 through Chapter 42 (2) Underground and limited access structures as addressed in Section 11.7 (3) High-rise buildings as required by other sections of this Code (4) Doors equipped with delayed-egress locks (5) Stair shaft and vestibule of smokeproof enclosures, for which the following also apply: (a) The stair shaft and vestibule shall be permitted to include a standby generator that is installed for the smokeproof enclosure mechanical ventilation equipment. (b) The standby generator shall be permitted to be used for the stair shaft and vestibule emergency lighting power supply. 7.9.1.2 For the purposes of 7.9.1.1, exit access shall include only designated stairs, aisles, corridors, ramps, escalators, and passageways leading to an exit. For the purposes of 7.9.1.1, exit discharge shall include only designated stairs, ramps, aisles, walkways, and escalators leading to a public way. 7.9.1.3 Where maintenance of illumination depends on changing from one energy source to another, a delay of not more than 10 seconds shall be permitted. 84 7.10 Marking of Means of Egress. 7.10.1 General. 7.10.1.1 Where Required. Means of egress shall be marked in accordance with Section 7.10 where required in Chapter 11 through Chapter 42. 7.10.1.2* Exits. Exits, other than main exterior exit doors that obviously and clearly are identifiable as exits, shall be marked by an approved sign that is readily visible from any direction of exit access. 7.10.1.3 Exit Stair Door Tactile Signage. Tactile signage shall be provided to meet the following criteria, unless otherwise provided in 7.10.1.4: (1) Tactile signage shall be located at each exit door requiring an exit sign. (2) Tactile signage shall read as follows: EXIT (3) Tactile signage shall comply with ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities. 7.10.1.4 Existing Exemption. The requirements of 7.10.1.3 shall not apply to existing buildings, provided that the occupancy classification does not change. 7.10.1.5 Exit Access. 7.10.1.5.1 Access to exits shall be marked by approved, readily visible signs in all cases where the exit or way to reach the exit is not readily apparent to National Fire Protection Assn. LIFE SAFETY CODE (NFPA 101) - 2003 the occupants. 7.10.1.5.2* New sign placement shall be such that no point in an exit access corridor is in excess of the rated viewing distance or 30 m (100 ft), whichever is less, from the nearest sign. 7.10.1.6* Floor Proximity Exit Signs. Where floor proximity exit signs are required in Chapter 11 through Chapter 42, such signs shall be located near the floor level in addition to those signs required for doors or corridors. The signs shall be illuminated in accordance with 7.10.5. Externally illuminated signs shall be sized in accordance with 7.10.6.1. The bottom of the sign shall be not less than 150 mm (6 in.) but not more than 455 mm (18 in. ) above the floor. For exit doors, the sign shall be mounted on the door or adjacent to the door, with the nearest edge of the sign within 100 mm (4 in.) of the door frame. 7.10.1.7* Floor Proximity Egress Path Marking. Where floor proximity egress path marking is required in Chapter 11 through Chapter 42, a listed and approved floor proximity egress path marking system that is internally illuminated shall be installed within 455 mm (18 in.) of the floor. The system shall provide a visible delineation of the path of travel along the designated exit access and shall be essentially continuous, except as interrupted by doorways, hallways, corridors, or other such architectural features. The system shall operate continuously or at any time the building fire alarm system is activated. The activation, duration, and continuity of operation of the system shall be accordance with 7.9.2. 7.10.1.8* Visibility. Every sign required in Section 7.10 shall be located and of such size, distinctive color, and design that it is readily visible and shall provide contrast with decorations, interior finish, or other signs. No decorations, furnishings, or equipment that impairs visibility of a sign shall be permitted. No brightly illuminated sign (for other than exit purposes), display, or object in or near the line of vision of the required exit sign that could detract attention from the exit sign shall be permitted. 7.10.1.9 Mounting Location. The bottom of new egress markings shall be located at a vertical distance of not more than 2030 mm (80 in.) above the top edge of the egress opening intended for designation by that marking. Egress markings shall be located at a horizontal distance of not more than the required width of the egress opening, as measured from the edge of the egress opening intended for designation by that marking to the nearest edge of the marking. 7.10.2* Directional Signs. A sign complying with 7.10.3 with a directional indicator showing the direction of travel shall be placed in every location where the direction of travel to reach the nearest exit is not apparent. 7.10.3* Sign Legend. 7.10.3.1 Signs required by 7.10.1 and 7.10.2 shall read as follows in plainly legible letters, or other appropriate wording shall be used: EXIT 7.10.3.2* Where approved by the authority having jurisdiction, pictograms shall be permitted. 7.10.4* Power Source. Where emergency lighting facilities are required by the applicable provisions of Chapter 11 through Chapter 42 for individual occupancies, the signs, other than approved self luminous signs, shall be illuminated by the emergency lighting facilities. The level of illumination of the signs shall be in accordance with 7.10.6.3 or 7.10.7 for the required emergency lighting duration as specified in 7.9.2.1. However, the level of illumination shall be permitted to decline to 60 percent at the end of the emergency lighting duration. 7.10.5 Illumination of Signs. 7.10.5.1* General. Every sign required by 7.10.1.2 or 7.10.1.5, other than where operations or processes require low lighting levels, shall be suitably illuminated by a reliable light source. Externally and internally illuminated signs shall be legible in both the normal and emergency lighting mode. 7.10.5.2* Continuous Illumination. 7.10.5.2.1 Every sign required to be illuminated by 7.10.6.3 and 7.10.7 shall be continuously illuminated as required under the provisions of Section 7.8 unless otherwise provided in 7.10.5.2.2. 7.10.5.2.2* Illumination for signs shall be permitted to flash on and off upon activation of the fire alarm system. 7.10.6 Externally Illuminated Signs. 7.10.6.1* Size of Signs. 7.10.6.1.1 Externally illuminated signs required by 7.10.1 and 7.10.2, other than approved existing signs, unless otherwise provided in 7.10.6.1.2, shall read EXIT, or other appropriate wording shall be used, in plainly legible letters sized as follows: (1) For new signs, the letters shall be not less than 150 mm (6 in.) high, with the principal strokes of letters not less than 19 mm (3/4 in.) wide. (2) For existing signs, the required wording shall be permitted to be in plainly legible letters not less than 100 mm (4 in.) high. (3) The word EXIT shall be in letters of a width not less than 51 mm (2 in.), except the letter I, and the minimum spacing between letters shall be not less than 9.5 mm ( /8 in. ) . (4) Sign legend elements larger than the minimum established in 7.10.6.1.1(1) through 7.10.6.1.1(3) shall use letter widths, strokes, and spacing in proportion to their height. 7.10.6.1.2 The requirements of 7.10.6.1.1 shall not apply to marking required by 7.10.1.3 and 7.10.1.6. 7.10.6.2* Size and Location of Directional Indicator. 7.10.6.2.1 Directional indicators, unless otherwise provided in 7.10.6.2.2, shall comply with the following: (1) The directional indicator shall be located outside of the EXIT legend, not less than 9.5 mm (3/8 in.) from any letter. (2) The directional indicator shall be of a chevron type, as shown in Figure 7.10.6.2.1. (3) The directional indicator shall be identifiable as a directional indicator at a distance of 12m (40 ft). (4) A directional indicator larger than the minimum established for compliance with 7.10.6.2.1(3) shall be proportionately increased in height, width and stroke. (5) The directional indicator shall be located at the end of the sign for the direction indicated. FIGURE 7.10.6.2.1 Chevron-Type Indicator. 7.10.6.2.2 The requirements of 7.10.6.2.1 shall not apply to approved existing signs. 7.10.6.3* Level of Illumination. Externally illuminated signs shall be illuminated by not less than 54 lux (5 ft-candles) at the illuminated surface and shall have a contrast ratio of not less than 0.5. 7.10.7 Internally Illuminated Signs. 7.10.7.1 Listing. Internally illuminated signs shall be listed in accordance with UL 924, Standard for Safety Emergency Lighting and Power Equipment, unless they meet one of the following criteria: (1) They are approved existing signs. (2) They are existing signs having the required wording in legible letters not less than 100mm (4 in.) high. (3) They are signs that are in accordance with 7.10.1.3 and 7.10.1.6. 7.10.7.2* Photoluminescent Signs. The face of a photoluminescent sign shall be continually illuminated while the building is occupied. The illumination levels on the face of the photoluminescent sign shall be in accordance with its listing. The charging illumination shall be a reliable light source as determined by the authority having jurisdiction. The charging light source shall be of a type specified in the product markings. 7.10.8 Special Signs. 7.10.8.1 Sign Illumination. 7.10.8.1.1 Where required by other provisions of this Code, special signs shall be illuminated. 7.10.8.1.2 Where emergency lighting facilities are required by the applicable provisions of Chapter 12 through Chapter 42, the required illumination of special signs shall additionally be provided under emergency lighting conditions. 7.10.8.2 Characters. Special signs, where required by other provisions of this Code, shall comply with the visual character requirements of ICC/ANSI A117. 1 American National Standard | for Accessible and Usable Buildings and Facilities. 7.10.8.3* No Exit. 7.10.8.3.1 Any door, passage, or stairway that is neither an exit nor a way of exit access and that is located or arranged so that it is likely to be mistaken for an exit shall be identified by a sign that reads as follows: NO EXIT 7.10.8.3.2 The NO EXIT sign shall have the word NO in letters 51 mm (2 in.) high, with a stroke width of 9.5 mm (3/8 in.), and the word EXIT in letters 25 mm (1 in.) high, with the word EXIT below the word NO, unless such sign is an approved existing sign. 7.10.8.4 Elevator Signs. Elevators that are a part of a means of egress (see 7.2.13.1) shall have signs with a minimum letter height of 16 mm (5/8 in.) posted in every elevator lobby as follows: (1) *Signs that indicate that the elevator can be used for egress, including any restrictions on use (2) *Signs that indicate the operational status of elevators 7.10.9 Testing and Maintenance. 7.10.9.1 Inspection. Exit signs shall be visually inspected for operation of the illumination sources at intervals not to exceed 30 days, or shall be periodically monitored in accordance with 7.9.3.1.3. 7.10.9.2 Testing. Exit signs connected to or provided with a battery-operated emergency illumination source, where required in 7.10.4, shall be tested and maintained in accordance with 7.9.3. 85 Limited Warranty Product Unit Warranty (Years) Battery Warranty Full (Years) Pro-Rata (Years) Liteforms Emergency Lighting Units LiteScape Series with Spectron option nicad battery models nicad with Spectron option EZ-2 Series with Spectron option LZ Series with Spectron option LZ High Capacity Series with Spectron option nicad battery models nicad with Spectron option LM Series lead-calcium battery models lead-calc. with Spectron option nicad battery models nicad with Spectron option EZ-2R Series with Spectron option T-Grid Series with Spectron option EXT-122-EM Series Lite2 Series with Spectron option Delite Series N4X Series with Spectron option AS Series with Spectron option wet lead-acid battery models wet lead-acid with Spectron option wet nicad battery models wet nicad with Spectron option IPS Series XPB Series UFO-3AW, UFO-4W models UFO-5W, UFO-12W models UFO-5AW models UFO-6W, UFO-6WI, UFO-6W-CLD, UFO-7W, UFO-7WI, UFO-LP and UFO-MH models LX LED exit AC-Only models Emergency models Emergency Spectron models DK incandescent exit AC-Only models Emergency models LT combo exit Spectron models NYXC combo exit SMC combo exit Sempra cast LED exit* AC-Only models Emergency models Emergency Spectron models NYDC cast LED exit AC-Only models Emergency models LN4X wet location LED exit AC-Only models Emergency models Emergency Spectron models Freedom LED aluminum exit AC-Only models Emergency models LEDS aluminum LED exit AC-Only models Emergency models 1 5 1 5 3 5 1 5 1 5 3 5 1 2 1 2 3 5 1 5 1 2 1 2 5 4 9 4 3 5 5 5 5 4 9 8 1 5 3 5 3 5 3 5 1 3 5 1 3 5 1 5 1 5 1 5 3 3 1 2 3 5 “ “ “ 1 2 1 2 3 5 3 5 1 3 5 1 3 5 1 2 1 2 1 2 3 3 1 2 3 5 “ “ “ 5 4 9 8 3 5 3 5 5 3 5 5 3 5 5 4 9 8 14 13 3 3 – – – – – – – 5 5 5 – 1 2 – 9 8 3 5 5 5 5 5 – 1 1 2 1 1 – 9 5 4 5 5 Liteforms Exit Signs 5 – – 5 1 9 5 Lifetime 5 5 – 1 – 9 5 5 5 – 1 2 – 9 8 5 5 – 1 – 4 5 5 – 1 – 9 * Includes Sempra, Sempra SC, SC-WL, MR and SERS Series exit signs. 86 Unit Warranty Product (Years) Battery Warranty Full (Years) Pro-Rata (Years) 5 5 – 1 – 9 5 5 – 1 – 9 5 5 5 – 1 2 – 9 8 5 – – 5 5 – 1 – 9 5 5 – 1 – 9 3 3 – 1 – 5 Liteforms Exit Signs NYX LED exit AC-Only models Emergency models CMX exit AC-Only models Emergency models LE edge-lit LED exit AC-Only models Emergency models Emergency Spectron models LES edge-lit LED exit AC-Only models NYE edge-lit LED exit AC-Only models Emergency models NYES edge-lit LED exit AC-Only models Emergency models DEX special wording exit AC-Only models Emergency models SlimLite Series CV Series CVEC Series CV3 LED exit AC-Only models Emergency models CVT Tandem LED exit CVD cast LED exit AC-Only models Emergency models CVER edge-lit LED exit AC-Only models Emergency models Clearview Life Safety Products 1 1 1 1 1 1 5 5 5 5 5 5 – 1 1 – 9 9 5 5 – 1 – 9 5 5 – 1 – 9 Consult factory for warranties available with AC Inverter Systems. Emergency Lighting Units and Batteries Dual-Lite warrants to the purchaser that its products have been carefully manufactured and inspected, and are warranted to be free from defect of workmanship and materials when used as intended. See chart at left for duration of warranties for units and batteries (fuses and lamps are excluded from all warranties). Batteries must be placed in service or recharged within nine (9) months from invoice date or ninety (90) days from recommended recharge date stamped on carton, whichever is longer (NiCad batteries excluded). The warranties are subject to proper installation and maintenance in accordance with the instructions supplied. Any abuse or misuse contrary to normal operation shall void this warranty. This warranty does not cover damages caused by installation in areas with other than normal temperatures and environmental conditions per application specifications. Dual-Lite assumes no responsibility for any damage to people, property, apparatus or otherwise resulting from improper installation or maintenance of its emergency lighting units. Warranty coverage shall not apply to any equipment of another manufacturer used in conjunction with Dual-Lite systems. Warranty does not cover damages caused by abuse, fire or acts of God. To obtain prior written approval to return defective items, please contact your local manufacturer’s representative. After prior written notification has been given and approval obtained for the return, merchandise may be returned, freight prepaid, to Dual-Lite. Customer is responsible for secure packaging of returned materials to provide best possible assurance against breakage in shipment. If, upon inspection, the merchandise is found to be defective replacement or repair shall be made. Dual-Lite’s sole obligation under this limited warranty is to repair or replace the defective parts or products, at its discretion, providing such defective parts or products are brought to its attention within the specified warranty time period, and does not include any other costs such as removal of defective parts or product, installation, labor or consequential damages of any kind, the exclusive remedy being to require such new parts or products to be furnished. All other warranties, expressed or implied, including warranties of merchantability or warranties of fitness for any particular purpose we hereby disclaim. Dual-Lite Distributors and Representatives have no authority to change this warranty without written permission from Dual-Lite. Dual-Lite reserves the right to determine the best method of correcting warranty problems. All specifications subject to change without notice. Some states do not allow the exclusion of limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Synchron Series Single-Phase Inverters ............................................. 88 to 91 Spectron LSN Series Single-Phase Inverters .................................... 92 to 101 Trident Series Three-Phase Inverters .................................................... 103 to 106 Auxiliary Transfer Switching Device ................................................................... 107 87 Single Phase Systems 88 Single Phase Systems 89 Single Phase Systems 90 Single Phase Systems 91 Single Phase Systems 92 Single Phase Systems 93 Single Phase Systems 94 Single Phase Systems 95 Single Phase Systems 96 Single Phase Systems 97 Single Phase Systems 98 Single Phase Systems Note: Batteries for all Spectron LSN inverter systems are shipped separately. Batteries must be installed and energized within six months of shipment or warranty is void. 99 Single Phase Systems 100 Single Phase Systems 101 Three Phase Systems 102 TRX Three Phase Systems 3-Phase rident Inverter Power Systems GENERAL SPECIFICATIONS INPUT Voltage: 120/208VAC, 60Hz 3-phase, 4-wire plus ground Voltage Range: +10%, -20% Frequency Range: 47-63Hz. User Interface Panel Current Distortion: 4% maximum reflected THD at full load Current Limit: 125% of full load input current Walk-ln: 20 seconds to full load Power Factor: 0.99 lagging minimum at full load Surge Protection: Sustains input surges without damage, per criteria listed in IEC 1000-4-5 ENVIRONMENTAL Operating Temperature: UPS: 32°F to 104°F (0°C to 40°C) Battery: 68°F to 86°F (20°C to 30°C) Relative Humidity: 0-95% non-condensing TRX Series 10 to 30 kVA, 3-Phase UPS Flexibility In Application The Dual-Lite Trident TRX Series’ quiet operation, small footprint and lightweight design is perfect for installation in computer rooms, yet the Trident TRX Series is rugged enough for factory floors or maintenance rooms. Precisely controlled system output is suitable for any lighting or critical life safety loads up to the full rated output capacity. Outstanding Features • Unmatched reliability • Smallest system footprint • Excellent efficiency with nonlinear and partial loads • Outstanding dynamic response • All-digital ActiveStar controls and graphical user interface • Power factor corrected • Harmonic current cancellation Operating Altitude: Up to 3,300 ft. (1,000m) without derating Acoustical Noise: Less than 54 dBA typical, measured 3.3 ft. (1 m) from the unit OUTPUT Voltage: 120/208VAC, 60Hz., 3-phase, 4-wire plus ground Voltage Adjustment Range: ±5% Voltage Regulation: 1% for balanced load 2% for 100% unbalanced load Dynamic Regulation: ±4% deviation for 100% load step ±1% for loss or return of AC input Transient Response Time: Recover to ±1% of steady state within 1 cycle Voltage Distortion: For linear loads, 1% THD. Less than 4% THD for 100% nonlinear loads without kVA/kW derating Phasing Balance: 120° ±0.5° for balanced load 120° ±1° for 100% unbalanced load Frequency Regulation: ±0.1% Load Power Factor Range: 0.70 lagging to 0.95 leading without derating Overload: 125% of full load for 10 minutes 150% for one minute, with true sinusoidal waveform Outstanding Support Assistance is available from the largest Customer service and Support network in the country. Standards Complies with UL 1778 (UPS) and UL 924 (Emergency) standards, and is CSA certified. 103 TRX Three Phase Systems Product Selector Size kVA/kW UPS Cabinet No. Battery Cabinet No. (1) 10/8 TRXSAA10114 TRXBATAR141BNR 15/12 TRXSAB10114 TRXBATBR271BNR 20/16 TRXSAC10114 TRXBATCR371BNR 30/24 TRXSAD10114 TRXBATDR311BNR(2) (1) 90 minute run time. Contact factory for other run times. (2) Two battery cabinets required on 30 kVA models Options 480 VAC Operation (Contact factory for proper configuration) Intellislot Relay Board Seismic Floor Kit Site Planning Data Trident UPS - 90 Minute Operation Battery System AC AC Input (1) Rating Voltage Current Nom. Battery Max. kVA kW Input Output Nom. Max. OCPD VDC kW Discharge 10-30 kVA, 3-Phase, 60 Hz. AC Output Mechanical Data Current No. Of Dimensions - WxDxH Weight Heat Dis Nom. OCPD Cabinets inches (mm) Ibs. (kg) BTU/hr (kWH) 10 8 208 208 28 35 50 288 9 37A 28 50 2 51x32.5x63 (1,295x826x1,600) 2,800 (1,275) 2,800 (0.82) 15 12 208 208 42 53 60 288 13 55A 42 60 2 51x32.5x63 (1,295x826x1,600) 3,350 (1,526) 4,200 (1.23) 20 16 208 208 56 70 80 288 18 73A 56 80 2 83x32.5x63 (2,057x826x1,600) 4,150 (1,890) 5,500 (1.61) 30 24 208 208 83 104 125 288 26 110A 83 125 3 142x32.5x63 (1,981x826x1,600) 6,650 (3,028) 8,300 (2.43) -- 1,3,7 -- -- -- 1,3,7 See Notes For Table (Below): 1,3,7 6 -- -- -- -- (1) Contact factory for 480 VAC applications. Cabinet Configurations 10 and 15 kVA Models 20 kVA Models 30 kVA Models NOTES FOR TABLE: 1. UPS input and bypass cables must be run in separate conduit from output cables 2. Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized ground conductors are recommended. Neutral conductors to be sized for full capacity per NEC 310-15 (b)(4). References are per NEC 1999. 3. Wiring requirements: AC Input: 3-phase, 4-wire, plus ground AC Output: 3-phase, 3- or 4-wire, plus ground 4. All wiring is to be in accordance with national and local electric codes. 5. Minimum access clearance is 3 ft. (0.9m) front and 18 in. (457mm) above the UPS. 6. Top or bottom cable entry through removable access plates. Punch plate to suit conduit size, then replace. 7. Control wiring and power wiring must be run in separate conduit. ADDITIONAL NOTES: • If site configuration includes a backup emergency generator, it is recommended that the engine generator set be properly sized and equipped for a UPS application. Generator options would typically include an isochronous governor (generator frequency regulation) and a UPS-compatible regulator (generator voltage regulation). Consult generator manufacturer for required generator options and sizing. • If site configuration includes an automatic transfer switch, refer to Power Line titled “Criteria for Application of Automatic Transfer Switches (ATS) With Uninterruptible Power Supply (UPS) Systems,” publication 91K-PLT-48-02. It is also recommended that the transfer switch be equipped with auxiliary contacts for UPS “on generator” current limit. Consult transfer switch manufacturer for required transfer switch options and sizing. • If site configuration requires an external isolated maintenance bypass circuit, it should be noted that utility AC input might not be in phase with the UPS AC output. Consult a Dual-Lite sales representative or applications engineer. 104 TRN Three Phase Systems 3-Phase rident Inverter Power Systems GENERAL SPECIFICATIONS INPUT Voltage: 208 or 480 VAC, 60 Hz (3-phase, 3-or 4-wire plus ground) Voltage Range: +10, -15% (no battery discharge at-20%) Frequency Range: 60 Hz, ± 5 Current Distortion: 10% maximum reflected THD at full load with optional input filter. 30% THD without filter Current Limit: 115% of full load input current Current Walk-in: 20 seconds to full load Power Factor: 0.80 lagging minimum at full load. Up to 0.96 lagging at full load with optional input filter Surge Protection: Sustains input surges without damage, per criteria listed in ANSI C62.41-1980 (IEEE 587) TRN Series 30 to 130 kVA, 3-Phase UPS • Unmatched heritage of reliability and availability • Smallest system footprint • Excellent efficiency with nonlinear loads and partial loads • Outstanding dynamic response • All-digital controls and graphical user interface Dual-Lite has reinvented the dualconversion UPS. The TridentTM Series is the result of an international design collaboration and more than a decade of advanced research. Every aspect of the TridentTM Series shows careful design and attention to detail. The rugged power train and advanced DSP controls were subjected to computer simulations and thermal analysis to ensure reliable performance in every environment. Even the physical packaging is uniquely efficient, to make fully configured systems more compact than our competitors. Best of all, it’s a Dual-Lite product designed to deliver an impressive millionhour critical bus MTBF. Voltage Distortion: For linear loads, 1% THD. Less than 2.5% THD for 100% nonlinear loads without kVA/kW derating Phasing Balance: 120° ±0.5° for balanced load. 120° ±1° for 100% unbalanced load Frequency Regulation: ±0.1% Load Power Factor Range: 1.0 to 0.7 lagging without derating Overload: 125% of full load for ten minutes. 150% for one minute, with true sinusoidal waveform STANDARDS Complies with UL 1778 (UPS) and UL 924 (Emergency) standards, and is CSA certified. ENVIRONMENTAL Operating Temperature: 0° to 40°C (UPS), 20° to 30°C (battery) Non-Operating Temperature: -20°C to 70°C Relative Humidity: 0-95% non-condensing Operating Altitude: Up to 6,600 feet (2000 meters) without derating Acoustical Noise: Less than 65 dBA 1 meter from unit (typical) OUTPUT Voltage: 208 or 480 VAC (3-phase, 4-wire plus ground) Voltage Adjustment Range: ±5% Voltage Regulation: ±0.5% for balanced load ±1.0% for 100% unbalanced load Dynamic Regulation: ±2.5% deviation for 100% load step. ±1% for loss or return of AC input Transient Response: Recover to ±1% of steady state within 1 cycle Slim-Line Distribution Cabinet kVA All Dimensions (In.) (WxDxH) 10 x 32.5 x 71 Weight (Ib) 250 Maintenance Bypass Cabinets Model L N P Q Dimensions (In.) (WxDxH) 25 x 32.5 x 71 25 x 32.5 x 71 31.7 x 32.5 x 71 31.7 x 32.5 x 71 Weight (Ib) 15-50 kVA 660 660 1,210 1,210 Weight (Ib) 65-80 kVA 750 750 1,320 1,320 Weight (Ib) 100-130 kVA 800 800 1,540 1,540 105 TRN Three Phase Systems Product Selector Size kVA/kW 30/24 40/32 50/40 65/52 80/64 100/80 130/104 UPS Cabinet No. (480/480) TRNSAD2026B TRNSAE2026B TRNSAF2026B TRNSAG2026B TRNSAH2026B TRNSAI2026B TRNSAJ2026B UPS Cabinet No. (208/208) TRNSAD1016B TRNSAE1016B TRNSAF1016B TRNSAG1016B TRNSAH1016B TRNSAI1016B TRNSAJ1016B Battery Pack No.* TRNBATDX471BNL TRNBATEX312BNL TRNBATFX372BNL TRNBATGX472BNL TRNBATHX274BNL TRNBATIX473BNL TRNBATJX474BNL * 90 minute run time. Contact factory for other run times. Options Programmable Relay Board Internal Modem Network Interface Card AS/400 Signal Cable Remote Alarm Status Panel Cabinet Configurations 30 kVA Models 40 - 50 kVA Models 65 kVA Models Site Planning Data 80 kVA Models Trident UPS - 90 Minute Operation Battery System AC AC Input Rating Voltage Current Nom. Battery Max. kVA kW Input Output Nom. Max. OCPD VDC kW Discharge 30 24 208 208 80 92 150 480 26 66A 30-130 kVA, 3-Phase, 60 Hz. AC Output Mechanical Data Current No. Of Dimensions - WxDxH Weight Heat Dis Nom. OCPD Cabinets inches (mm) Ibs. (kg) BTU/hr (kWH) 83 125 2 80.7x32.5x71 (2,050x826x1,803) 7,250 (3,303) 8,500 (2.49) 30 24 480 208 33 38 60 480 26 66A 83 125 2 80.7x32.5x71 (2,050x826x1,803) 7,150 (3,257) 30 24 480 480 33 38 60 480 26 66A 36 50 2 80.7x32.5x71 (2,050x826x1,803) 6,950 (3,166) 11,000 (3.22) 7,500 (2.19) 40 32 208 208 106 122 175 480 34 88A 111 150 3 130x32.5x71 (3,294x826x1,803) 9,600 (4,373) 11,000 (3.22) 40 32 480 208 44 51 80 480 34 88A 111 150 3 130x32.5x71 (3,294x826x1,803) 9,500 (4,328) 10,000 (2.93) 40 32 480 480 44 51 80 480 34 88A 48 60 3 130x32.5x71 (3,294x826x1,803) 9,300 (4,237) 10,000 (2.93) 50 40 208 208 133 153 225 480 43 109A 139 175 3 130x32.5x71 (3,294x826x1,803) 10,200 (4647) 14,000 (4.10) 50 40 480 208 55 63 90 480 43 109A 139 175 3 130x32.5x71 (3,294x826x1,803) 10,100 (4601) 12,000 (3.51) 50 40 480 480 55 63 90 480 43 109A 60 80 3 65 52 208 208 171 196 300 480 55 141A 180 25 3 137.4x32.5x71 (3,490x826x1,803) 12,800 (5831) 18,000 (5.27) 65 52 480 208 70 81 125 480 55 141A 180 225 3 137.4x32.5x71 (3,490x826x1,803) 12,600 (5740) 15,000 (4.39) 65 52 480 480 70 81 125 480 55 141A 78 100 3 137.4x32.5x71 (3,490x826x1,803) 12,400 (5649) 15,000 (4.39) 80 64 208 208 210 241 350 480 68 174A 222 300 5 139.4x32.5x71 (3,541x826x1,803) 14,700 (6697) 22,000 (6.44) 80 64 480 208 87 100 150 480 68 174A 222 300 5 139.4x32.5x71 (3,541x826x1,803) 14,500 (6606) 18,000 (5.27) 80 64 480 480 87 100 150 480 68 174A 96 125 5 139.4x32.5x71 (3,541x826x1,803) 14,300 (6515) 18,000 (5.27) 100 80 208 208 261 300 500 480 85 218A 278 350 4 196.2x32.5x71 (3,713x826x1,803) 18,950 (8633) 26,000 (7.61) 100 80 480 208 108 124 200 480 85 218A 278 350 4 196.2x32.5x71 (3,713x826x1,803) 18,750 (8542) 21,000 (6.14) 100 80 130x32.5x71 (3,294x826x1,803) 9,900 (4510) 12,000 (3.51) 480 480 108 124 200 480 85 218A 120 150 4 196.2x32.5x71 (3,713x826x1,803) 18,550 (8451) 21,000 (6.14) 130 104 208 208 339 390 600 480 111 283A 361 450 5 245.2x32.5x71 (6,228x826x1,803) 24,000 (10934) 33,000 (9.66) 130 104 480 208 140 161 250 480 111 283A 361 450 5 245.2x32.5x71 (6,228x826x1,803) 23,800 (10843) 27,000 (7.90) 130 104 480 480 140 161 250 480 111 283A 156 200 5 245.2x32.5x71 (6,228x826x1,803) 23,600 (10751) 27,000 (7.90) -- -- -- 1,3,7 1,3,7 -- See Notes For Table (Below): -- 1,3,7 NOTES FOR TABLE: 1. The unit’s input and bypass cables must be run in separate conduit from output cables. 2. Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized ground conductors are recommended. Neutral conductors to be sized for full capacity per NEC 310-15(b)(4). References are per NEC 1999. 3. Wiring requirements: AC Input: 3-phase, 3-wire plus ground or 3-phase, 4-wire plus ground AC Output: 3-phase, 4-wire plus ground DC Input: 2-wire (positive and negative), plus ground 4. All wiring is to be in accordance with national and local electrical codes. 5. Minimum access clearance is 3 feet front and 1 foot above the unit. 6. Top or bottom cable entry through removable access plates. Cut plate to suit conduit size then replace. 7. Control wiring and power wiring must be run in separate conduit. 8. Weights and dimensions shown include battery cabinets. 9. OCPD-Overcurrent Protection Device. 106 130 kVA Models 100 kVA Models -- 8 8 -- ADDITIONAL NOTES: • If site configuration includes a back-up emergency generator, it is recommended that the engine generator set be properly sized and equipped for the unit’s application. Generator options would typically include an isochronous governor (generator frequency regulation) and a UPS-compatible regulator (generator voltage regulation). Consult generator manufacturer for required generator options and sizing. • If site configuration includes an automatic transfer switch, refer to the Power Line titled “Criteria for Application of Automatic Transfer Switches (ATS) with Uninterruptible Power Supply (UPS) Systems” publication 91K-PLT-48-02. It is also recommended that the transfer switch be equipped with auxiliary contacts for the unit’s “on generator“ current limit. Consult transfer switch manufacturer for required transfer switch options and sizing. • If site configuration requires an external isolated maintenance bypass circuit, it should be noted that utility AC input may not be in phase with the unit’s AC output. Consult local sales representative or applications engineer. ATSD Auxiliary Transfer Switching Device Features • Device allows generator or inverter supplied egress lighting fixtures to be switched • For factory or field installation • Compatible with all fluorescent fixtures • Easy installation inside of ballast channel • For use with switched fluorescent lighting fixtures • • • • Battery case made of galvanized steel Universal 120/277VAC operation Low power consumption Temperature range: 0°C to 50°C (32°F to 122°F) • UL Listed Ordering Information ATSD Installation The ATSD auxiliary transfer device does not affect normal fixture operation and comes fully assembled to mount in the fixture ballast channel. In addition to available wiring, the device requires a direct, unswitched connection to a generator- or invertersupplied emergency panel and an unswitched source on the same branch circuit as the switched supply (see diagram below). Application Dimensions 8.0” 20.4cm 1.18” 3.0cm 1.18” 3.0cm The ATSD auxiliary transfer switching device works in conjunction with an auxiliary generator or inverter power system to power existing fluorescent fixtures for egress lighting regardless of fixture wall switch position. The device consists of relay switching circuitry and fusing in one compact galvanized steel case. One auxiliary transfer switch device per fixture can be used to bypass fixture wall switch allowing the building’s generator to bring on switchable fixtures and not just those on “night-light” circuits. The auxiliary transfer switch device is suitable for use in indoordry or damp location fixtures. Recommended applications include: auditoriums, classrooms, or any other location with generator- or invertersupplied emergency lighting. 107 Notes 108 Notes 109 Notes 110 Dual-Lite • A Hubbell Lighting, Inc. Life Safety Products Brand • www.dual-lite.com Copyright© Hubbell Lighting, Inc., All Rights Reserved • Specifications subject to change without notice. • Printed in U.S.A. 0603254 3/06
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23 Instance ID : uuid:431f8474-c5b6-4aff-9ce1-d1a4a38b0921 Document ID : adobe:docid:indd:d4117685-aeb2-11da-8710-e2d54255d799 Rendition Class : proof:pdf Derived From Instance ID : d4117684-aeb2-11da-8710-e2d54255d799 Derived From Document ID : adobe:docid:indd:c20d943a-ae8b-11da-8710-e2d54255d799 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches Manifest Reference Document ID : adobe:docid:photoshop:fad6cb1b-0412-11da-ac88-afb10cd33dca, adobe:docid:photoshop:5adc27cf-149c-11da-bef5-fe11c0148134, adobe:docid:photoshop:0dc90bbc-0c4e-11d8-900f-cb75de43c9a9, adobe:docid:photoshop:ffebb212-3b6b-11d8-8729-8425211b5967 Create Date : 2007:06:19 17:00:38-04:00 Modify Date : 2007:06:19 18:06:52-04:00 Metadata Date : 2007:06:19 18:06:52-04:00 Creator Tool : Adobe InDesign CS2 (4.0.5) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 7675 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 7.0 Trapped : False Has XFA : No Page Count : 112 Creator : Adobe InDesign CS2 (4.0.5)EXIF Metadata provided by EXIF.tools