Installation Directions

2014-09-04

: Pdf 57757-Installationsheet 57757-InstallationSheet 006187 Batch7 unilog

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadInstallation Directions
Open PDF In BrowserView PDF
(2-foot)

(3-foot)

(latest
LED24T8SM-96X2-xxx-x01Wxx LED36T8SM-144X2-xxx-x01Wxx
generation)
(previous LED24T8SM-144-xxx-001Wxx
generation)

(4-foot)

(5-foot)

PAGE 1 of 2

23105 Kashiwa Court, Torrance, CA 90505
Phone: (800) 579.4875 / (310) 534.1505
Fax: (310) 534.1424
E-mail: info@ledtronics.com
Website: ledtronics.com

LED48T8SM-192X2-xxx-x01Wxx LED60T8SM-240X2-xxx-x01Wxx
LED48T8SM-276-xxx-001Wxx

LED60T8SM-576-xxx-001Wxx

SEE PAGE 2 FOR MORE INSTALLATION INSTRUCTIONS
READ AND FOLLOW ALL PRECAUTIONS AND INSTALLATION INSTRUCTIONS PRIOR TO INSTALLING LUMINAIRE
PACKAGE INCLUDES: LED Tube(s) + Caution Label + Installation Instructions

w w w.LE D t r o n i c s.co m

Installation Instructions
LED Tube Lights, Two Pins at Each End (G13 Bipin Bases)
AC Line Voltage

UNPACKING After unpacking and saving packing materials, examine the Light Tube and check for any possible damage that
THE LEDTRONICS LED T8 LIGHT TUBE could have resulted from transport. If damaged, notify LEDtronics and return the tube(s) in the packaging.

 Use of the ETL-listed T8 lamps in conjunction with bypassing the ballast does not effect the overall
Certification status, since the fixture is covered by the Listing of the lamp and its installation instructions.

DANGER – RISK OF SHOCK: Disconnect Power Before Installation
ENSURE THAT POWER IS OFF WHEN INSTALLING, REMOVING OR CHANGING LEDT8 TUBE LAMPS.
DO NOT TOUCH/HANDLE TUBES WITH POWER APPLIED (ON).

Important Safety Instructions
■■ WARNING - Risk of fire or electric shock. The electrical rating
of these products is 90-290 VAC; the installer must determine
whether they have 90-290 V at the luminaire before installation.
■■ WARNING - Risk of fire or electric shock. Reflector kit installation
requires knowledge of fluorescent lighting luminaire electrical
systems. If not qualified, do not attempt installation–Contact a
qualified electrician.
■■ WARNING - Risk of fire or electric shock. Install this kit only in
luminaires that have the construction features and dimensions
shown in the photographs and/or drawings.
■■ WARNING - To prevent wiring damage or abrasion, do not expose
wiring to edges of sheet metal or other sharp objects.

■■ Do not make or alter any open holes in an enclosure of wiring or
electrical components during kit installation.
■■ THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF
A FLUORESCENT LUMINAIRE WHERE THE SUITABILITY OF THE
COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES
HAVING JURISDICTION.
■■ For lamp replacement, contact Ledtronics and use only LEDtronics
LED Tube lamps (G13 Base).
■■ Not for use with light dimmers.
■■ This device is not intended for use with emergency exit fixtures or
emergency exit lights.
■■ LEDtronics suggests installing a luminaire disconnect for protection
when servicing fluorescent lights.

The instructions in these guidelines cannot anticipate all conceivable wiring situations.
ISO

9001:2008
CERTIFIED by DNV

© 2013 LEDtronics, Inc.

INSTR-LEDXXT8SM-0001-E / Rev. D 10/2013

■■ THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE
APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH
THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.

If the fluorescent tube fixture HAS A BALLAST (and starter, if separate)
starter
1 Make certain that the (electronic
3
ballasts do not have a
ballast
separate starter)
fixture’s line voltage is
compatible with the
LEDtronics tube [90–290VAC].
LIGHTING FIXTURE
6

2 Remove the old T8 fluorescent tube from the fixture

2

OLD TUBE
4
5

pictured.)

6 Install LED tube with LEDs
LEDTRONICS
directed to beam their light out
lens
4
protective TUBE
of the fixture.
film
7 Place cautionary label in a location inside the fixture
where the next bulb installer will see it.

* WIRING EXCEPTION when bypassing a fluorescent instant-on ballast:

If the fixture’s bipin sockets are shunted**, then connect a wire at each end.
(Connect hot wire to a pin of the socket at ONE END, and connect cold wire to a pin of the socket at the OTHER END.)
DO NOT connect both power wires at the same shunted bipin socket end.

If the fluorescent tube fixture has NO BALLAST

** Shunted sockets have a jumper wire connecting the bipins within
the socket, and are used in “instant-on” fluorescent fixtures. This
wiring exception pertains to converting instant-on ballasted
fluorescent fixtures to LED ballast-free fixtures.

. . . Then the fixture should have a cautionary label identifying it as having
been rewired for LED lamps, and to never install fluorescent lamps in it.

Affix the LEDtronics cautionary label to the fixture if one is not present, and if the fixture already uses LED tube lights,
or the installer knows the fixture does not use a ballast.

90VAC to
290VAC
Input

SIMPLIFIED WIRING

As illustrated above: Before installation,
remove the protective pin guards.
Before applying power, remove
the lens protector film from the
LEDtronics LED tube light .

1

(The appearance of your
lamp’s pinguards may
vary from that pictured.)

Hot Wire to any pin
on one end.

w w w.LE D t r o n i c s.co m

4 Remove the protective
pin guard caps from the
LEDtronics tube, and. . .
5 Peel the lens protecguard caps
tive plastic film from the (Pin
may vary in
appearance
LEDtronics tube lens.
from that

3 Remove or bypass ballast *
(and starter, if present)

3

PAGE 2 of 2

DANGER – RISK OF SHOCK: Disconnect Power Before Installation

(Type with 1 hot wire, 1 cold wire,
with or without ground wire)

2

Cold Wire to any other pin*

LEDTRONICS LED T8 TUBE WITH BI-PIN BASE

When installing, be
certain the tube lamp’s LEDs
and their light beams are
directed away from the fixture.

The hot wire (line/black) can connect to ANY one of the pins at one end.
The cold wire (neutral/white) connects to ANY ONE of the other three
pins at either end.*

Wiring for fixtures with MULTIPLE TUBES (2, 3 or 4-tube fixtures)
Protective end
caps need to be
removed before
tube installation.

The protective film
covering the tube lens
needs to be peeled off
before turning the
lamp on.

WIRING WILL
BYPASS
BALLAST
(If present
on fixture)
STARTER
WIRING WILL
BYPASS
STARTER
(If present
on fixture)

SIMPLIFIED WIRING
Hot Wire to any pin
on one end.

90VAC to
290VAC
Input

(Type with 1 hot wire, 1 cold wire,
with or without ground wire)

Cold Wire to any other pin *

LEDTRONICS LED T8 TUBE WITH BI-PIN BASES
The hot wire (line/black) can sequentially link by ANY ONE
of the pins on the LED tubes.
The cold wire (neutral/white) can sequentially link by
ANY OF THE OTHER THREE pins on the LED tube.*
LEDTRONICS LED T8 TUBE WITH BI-PIN BASES

LEDTRONICS LED T8 TUBE WITH BI-PIN BASES

Be certain the tube lamp’s LEDs and their
light beams are directed outward
from the fixture.

LEDTRONICS LED T8 TUBE WITH BI-PIN BASES
Adhesive label included with LEDtronics tubes explains this fixture has been modified
for LED tube lights and no longer accepts fluorescent bulbs requiring a ballast.
> Place the provided label in a visible location inside the fixture.

ISO

9001:2008
CERTIFIED by DNV

© 2013 LEDtronics, Inc.

INSTR-LEDXXT8SM-0001-E / Rev. D 10/2013

BALLAST



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Instance ID                     : uuid:cdcad603-6b27-4a71-9ba1-4813424ae771
Original Document ID            : adobe:docid:indd:9fe7278d-a8e9-11e0-8aff-bf3b91d0c747
Document ID                     : xmp.id:2AD8E06C8936E3118B71FF641734A32A
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:C213C081FF31E311B72DA5C772D9F311
Derived From Document ID        : adobe:docid:indd:9fe7278d-a8e9-11e0-8aff-bf3b91d0c747
Derived From Original Document ID: adobe:docid:indd:9fe7278d-a8e9-11e0-8aff-bf3b91d0c747
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2013:10:16 10:36:01-07:00
Metadata Date                   : 2013:10:16 10:36:02-07:00
Modify Date                     : 2013:10:16 10:36:02-07:00
Create Date                     : 2013:10:16 10:36:01-07:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu