Installation Directions
2014-09-04
: Pdf 57757-Installationsheet 57757-InstallationSheet 006187 Batch7 unilog
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
(2-foot) (3-foot) (latest LED24T8SM-96X2-xxx-x01Wxx LED36T8SM-144X2-xxx-x01Wxx generation) (previous LED24T8SM-144-xxx-001Wxx generation) (4-foot) (5-foot) PAGE 1 of 2 23105 Kashiwa Court, Torrance, CA 90505 Phone: (800) 579.4875 / (310) 534.1505 Fax: (310) 534.1424 E-mail: info@ledtronics.com Website: ledtronics.com LED48T8SM-192X2-xxx-x01Wxx LED60T8SM-240X2-xxx-x01Wxx LED48T8SM-276-xxx-001Wxx LED60T8SM-576-xxx-001Wxx SEE PAGE 2 FOR MORE INSTALLATION INSTRUCTIONS READ AND FOLLOW ALL PRECAUTIONS AND INSTALLATION INSTRUCTIONS PRIOR TO INSTALLING LUMINAIRE PACKAGE INCLUDES: LED Tube(s) + Caution Label + Installation Instructions w w w.LE D t r o n i c s.co m Installation Instructions LED Tube Lights, Two Pins at Each End (G13 Bipin Bases) AC Line Voltage UNPACKING After unpacking and saving packing materials, examine the Light Tube and check for any possible damage that THE LEDTRONICS LED T8 LIGHT TUBE could have resulted from transport. If damaged, notify LEDtronics and return the tube(s) in the packaging. Use of the ETL-listed T8 lamps in conjunction with bypassing the ballast does not effect the overall Certification status, since the fixture is covered by the Listing of the lamp and its installation instructions. DANGER – RISK OF SHOCK: Disconnect Power Before Installation ENSURE THAT POWER IS OFF WHEN INSTALLING, REMOVING OR CHANGING LEDT8 TUBE LAMPS. DO NOT TOUCH/HANDLE TUBES WITH POWER APPLIED (ON). Important Safety Instructions ■■ WARNING - Risk of fire or electric shock. The electrical rating of these products is 90-290 VAC; the installer must determine whether they have 90-290 V at the luminaire before installation. ■■ WARNING - Risk of fire or electric shock. Reflector kit installation requires knowledge of fluorescent lighting luminaire electrical systems. If not qualified, do not attempt installation–Contact a qualified electrician. ■■ WARNING - Risk of fire or electric shock. Install this kit only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings. ■■ WARNING - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. ■■ Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. ■■ THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A FLUORESCENT LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION. ■■ For lamp replacement, contact Ledtronics and use only LEDtronics LED Tube lamps (G13 Base). ■■ Not for use with light dimmers. ■■ This device is not intended for use with emergency exit fixtures or emergency exit lights. ■■ LEDtronics suggests installing a luminaire disconnect for protection when servicing fluorescent lights. The instructions in these guidelines cannot anticipate all conceivable wiring situations. ISO 9001:2008 CERTIFIED by DNV © 2013 LEDtronics, Inc. INSTR-LEDXXT8SM-0001-E / Rev. D 10/2013 ■■ THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. If the fluorescent tube fixture HAS A BALLAST (and starter, if separate) starter 1 Make certain that the (electronic 3 ballasts do not have a ballast separate starter) fixture’s line voltage is compatible with the LEDtronics tube [90–290VAC]. LIGHTING FIXTURE 6 2 Remove the old T8 fluorescent tube from the fixture 2 OLD TUBE 4 5 pictured.) 6 Install LED tube with LEDs LEDTRONICS directed to beam their light out lens 4 protective TUBE of the fixture. film 7 Place cautionary label in a location inside the fixture where the next bulb installer will see it. * WIRING EXCEPTION when bypassing a fluorescent instant-on ballast: If the fixture’s bipin sockets are shunted**, then connect a wire at each end. (Connect hot wire to a pin of the socket at ONE END, and connect cold wire to a pin of the socket at the OTHER END.) DO NOT connect both power wires at the same shunted bipin socket end. If the fluorescent tube fixture has NO BALLAST ** Shunted sockets have a jumper wire connecting the bipins within the socket, and are used in “instant-on” fluorescent fixtures. This wiring exception pertains to converting instant-on ballasted fluorescent fixtures to LED ballast-free fixtures. . . . Then the fixture should have a cautionary label identifying it as having been rewired for LED lamps, and to never install fluorescent lamps in it. Affix the LEDtronics cautionary label to the fixture if one is not present, and if the fixture already uses LED tube lights, or the installer knows the fixture does not use a ballast. 90VAC to 290VAC Input SIMPLIFIED WIRING As illustrated above: Before installation, remove the protective pin guards. Before applying power, remove the lens protector film from the LEDtronics LED tube light . 1 (The appearance of your lamp’s pinguards may vary from that pictured.) Hot Wire to any pin on one end. w w w.LE D t r o n i c s.co m 4 Remove the protective pin guard caps from the LEDtronics tube, and. . . 5 Peel the lens protecguard caps tive plastic film from the (Pin may vary in appearance LEDtronics tube lens. from that 3 Remove or bypass ballast * (and starter, if present) 3 PAGE 2 of 2 DANGER – RISK OF SHOCK: Disconnect Power Before Installation (Type with 1 hot wire, 1 cold wire, with or without ground wire) 2 Cold Wire to any other pin* LEDTRONICS LED T8 TUBE WITH BI-PIN BASE When installing, be certain the tube lamp’s LEDs and their light beams are directed away from the fixture. The hot wire (line/black) can connect to ANY one of the pins at one end. The cold wire (neutral/white) connects to ANY ONE of the other three pins at either end.* Wiring for fixtures with MULTIPLE TUBES (2, 3 or 4-tube fixtures) Protective end caps need to be removed before tube installation. The protective film covering the tube lens needs to be peeled off before turning the lamp on. WIRING WILL BYPASS BALLAST (If present on fixture) STARTER WIRING WILL BYPASS STARTER (If present on fixture) SIMPLIFIED WIRING Hot Wire to any pin on one end. 90VAC to 290VAC Input (Type with 1 hot wire, 1 cold wire, with or without ground wire) Cold Wire to any other pin * LEDTRONICS LED T8 TUBE WITH BI-PIN BASES The hot wire (line/black) can sequentially link by ANY ONE of the pins on the LED tubes. The cold wire (neutral/white) can sequentially link by ANY OF THE OTHER THREE pins on the LED tube.* LEDTRONICS LED T8 TUBE WITH BI-PIN BASES LEDTRONICS LED T8 TUBE WITH BI-PIN BASES Be certain the tube lamp’s LEDs and their light beams are directed outward from the fixture. LEDTRONICS LED T8 TUBE WITH BI-PIN BASES Adhesive label included with LEDtronics tubes explains this fixture has been modified for LED tube lights and no longer accepts fluorescent bulbs requiring a ballast. > Place the provided label in a visible location inside the fixture. ISO 9001:2008 CERTIFIED by DNV © 2013 LEDtronics, Inc. INSTR-LEDXXT8SM-0001-E / Rev. D 10/2013 BALLAST
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Instance ID : uuid:cdcad603-6b27-4a71-9ba1-4813424ae771 Original Document ID : adobe:docid:indd:9fe7278d-a8e9-11e0-8aff-bf3b91d0c747 Document ID : xmp.id:2AD8E06C8936E3118B71FF641734A32A Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:C213C081FF31E311B72DA5C772D9F311 Derived From Document ID : adobe:docid:indd:9fe7278d-a8e9-11e0-8aff-bf3b91d0c747 Derived From Original Document ID: adobe:docid:indd:9fe7278d-a8e9-11e0-8aff-bf3b91d0c747 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2013:10:16 10:36:01-07:00 Metadata Date : 2013:10:16 10:36:02-07:00 Modify Date : 2013:10:16 10:36:02-07:00 Create Date : 2013:10:16 10:36:01-07:00 Creator Tool : Adobe InDesign CS6 (Windows) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools