SS 2000 INSTALL Installation Directions
2014-07-04
: Pdf 583235-Installationsheet 583235-InstallationSheet 009456 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Safety Technology International, Inc. Safety Technology International (Europe) Ltd. 2306 Airport Road • Waterford, Michigan 48327-1209 Phone: 248-673-9898 • Fax: 248-673-1246 Toll Free: 800-888-4784 • E-mail: info@sti-usa.com Web: www.sti-usa.com Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only) E-mail: info@sti-europe.com • Web: www.sti-europe.com EXISTING STANDARD SINGLE GANGBOX HOUSING INDEXING SLOTS 02050 BACKPLATE ASSEMBLY (SEE REVERSE SIDE) OCTAGON KEY RESET BUTTON (#0) RED, GREEN, YELLOW, WHITE AND BLUE SH PU 10102 KEY RESET SWITCH RE HE 102722 SPACER RED, GREEN, YELLOW, WHITE AND BLUE. STI RECOMMENDS THE USE OF THIS SPACER FOR SWITCH CLEARANCE ON STANDARD SINGLE GANG BOXES. ASSIGNED A 5VA FLAMMABILITY RATING. SEE NOTE IN PRODUCT DIMENSION VIEW. 10271 STATION HOUSING RED, GREEN, YELLOW, WHITE AND BLUE 10100 PUSH/TURN RESET BUTTON (#1) 10274 OCTAGON SHELL RED, GREEN, YELLOW, WHITE AND BLUE STATION LABEL *NOTE: TO PROVIDE ADEQUATE CLEARANCE FOR INSTALLATION, 19001 SCREW (1) PROVIDED MAY REQUIRE: SUB-102722 SPACER, OR RACO #660 W/1/2" K.O. AND RACO #653 EXTENSION RING. ALSO RACO #696 MASONRY BOX. PRODUCT DIMENSIONS P SH 10105 MOMENTARY BUTTON (#4)* 1.62 in. (41mm) 4.87 in. (124mm) 10104 KEY BUTTON (#3) KEY REQUIRED TO ACTIVATE - IN ACTIVATE MODE KEY CAN BE REMOVED PU 3.25 in. (82mm) KEYS (2) PROVIDED KEYS (2) PROVIDED *SS-2**4 and LT1-UL NOTES: For access control installations, power for the LT-1UL Timer must be supplied by a power source listed to UL294. When used for access control, this device shall be used as part of an access controlled egress door system. It is up to the local AHJ to allow use of this device in place of an automatic sensor. For higher security installations, lower time limits should be used. For SS-2**4 and LT1-UL the enclosed timer is to be used and installed per the enclosed LT-1UL installation sheet. *SS-2**4 and LT1-UL maximum rating 30 VDC 3A. REMARQUES POUR *SS-2**4 et LT1-UL: Pour les installations de contrôle d’accès, l’alimentation de la minuterie LT-1UL doit être fournie par une source homologuée UL294. Lorsque cet appareil est utilisé aux fins de contrôle d’accès, il doit faire partie d’un système de porte de sortie à accès contrôlé. Il incombe donc à l’AHJ local d’autoriser l’utilisation de cet appareil au lieu d’un capteur automatique. Pour les installations de sécurité plus renforcée, des délais inférieurs doivent être utilisés. Pour les modèles SS-2**4 et LT1-UL, la minuterie intégrée doit être installée et utilisée suivant la fiche d’installation LT-1UL fournie. La cote maximale des modèles *SS-2** 4 et LT1-UL est de 30 VCC 3A. Electronic warranty form at www.sti-usa.com/wc14 INSTALLATION OF SS-2000 SERIES STOPPER® STATION All specifications and information shown were current as of publication, and are subject to change without notice. 1027IS MAY2011 2.25 in. (57mm) Safety Technology International, Inc. Safety Technology International (Europe) Ltd. 2306 Airport Road • Waterford, Michigan 48327-1209 Phone: 248-673-9898 • Fax: 248-673-1246 Toll Free: 800-888-4784 • E-mail: info@sti-usa.com Web: www.sti-usa.com Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only) E-mail: info@sti-europe.com • Web: www.sti-europe.com STRIP 1/4 in. OF WIRE INSULATION INSERT IN TERMINAL (AS SHOWN) THEN USING A PHILLIPS SCREWDRIVER TURN CLOCKWISE UNTIL TIGHT. OU TG OIN G 10196 NO (1) PROVIDED TERMINAL BLOCK 10198 NC (1) PROVIDED SEE VIEW IN DIRECTION OF ARROW FOR CONTACT INDENTIFIER LOCATIONS UP TO (3) TERMINALS MAY BE USED FOR EACH STATION ASSEMBLY. 19010 SCREWS #6-32 x 1 OUTLET BOX (2) PROVIDED. SCREWS #6-32 x 1.50 WHEN USING 102722 SPACER (SEE REVERS SIDE). A 19021 GROUND LUG (1) PROVIDED VIEW IN DIRECTION OF ARROW A INSTALLATION OF ELECTRICAL WIRE INTO TERMINAL BLOCK INC OM ING SEPARATION OF TERMINAL ASSEMBLY. FROM BUTTON ASSEMBLY IS AS FOLLOWS: GRASP TERMINAL HOUSING AND USING THUMB APPLY PRESSURE DOWNWARD, REMOVE TERMINAL. BUTTON LOCK NUT TERMINAL BLOCK RELEASE LEVER MUST FACE UPWARD AS SHOWN FOR SWITCH TO FUNCTION CORRECTLY. REMOVAL OF TERMINAL BLOCK FROM TERMINAL HOUSING: INSERT SMALL SCREWDRIVER (AS SHOWN) AND PRY UPWARD, REMOVE TERMINAL. NO 1 ELECTRICAL TERMINAL BLOCK UP TO 3 TERMINALS MAY BE USED NC 3 10272 BACKPLATE GREEN, YELLOW, WHITE AND BLUE 4 2 INSERT NOTCH, AS SHOWN THEN ROTATE UPWARD VIEW IN DIRECTION OF ARROW A INSTALLATION AND REMOVAL OF TERMINAL BLOCKS AND TERMINAL BLOCK ASSEMBLY FROM BUTTON ASSEMBLY TERMINAL BLOCK LEGEND ALL TERMINALS ACCEPT TWO 12 TO 18 (AWG) NO — NORMALLY OPEN VOLTAGE RATED AVERAGE CURRENT NC — NORMALLY CLOSED 250 VDC 1 AMP C — COMMON 600 VAC 3 AMP NOTE: SS-2XX4/LT CONTACTS ON FORM C TIMER RATED: INSTALLATION OF SS-2000 SERIES STOPPER® STATION All specifications and information shown were current as of publication, and are subject to change without notice. 1027IS MAY2011 120 VAC, 3A 28 VDC, 3A
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 Create Date : 2014:06:11 08:17:20-05:00 Producer : QuarkXPress(R) 8.12 Modify Date : 2014:06:11 08:17:20-05:00 X Press Private : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments Title : SS-2000 INSTALL Creator : QuarkXPress(R) 8.12EXIF Metadata provided by EXIF.tools