Product Detail Manual
2014-10-17
: Pdf 58537-Attachment 58537-Attachment 782113 Batch10 unilog
Open the PDF directly: View PDF
.
Page Count: 55
| Download | |
| Open PDF In Browser | View PDF |
IEC Contactors and Overload Relays Technical Solutions Mini Series Contactors and Overload Relays Freedom Series Contactors and Overload Relays Modular Series Contactors and Overload Relays Mini Series Contactors and Overload Relays Contactors 2 Contactors – reversing 2 Accessories 3 Technical data 4 Lighting circuit switching 6 Overload relay 7 Technical data 7 Dimensions 8 Freedom Series Contactors and Overload Relays Contactors 10 Accessories 11 Thermal overload relays 14 Type 2 Co-ordination Selection procedure 16 Technical data 18 Dimensions 33 Modular Series Contactors and Overload Relays Contactors 38 Accessories 40 Technical data 42 Dimensions 47 Thermal overload relays 49 Technical data 50 Dimensions 54 Mini Series Contactors and Overload Relays 2 April 2005 Mini Series – 4 and 5.5kW Catalogue numbers Contactors AC3 rating 3ph 400/440V Number of contacts Main Auxiliary Catalogue numbers 3 N.O. 3 N.O. 4 N.O. 1 N.O. 1 N.C. CE12BNC310* CE12BNC301* CE12BNC400* 3 N.O. 3 N.O. 4 N.O. 1 N.O. 1 N.C. CE12CNC310* CE12CNC301* CE12CNC400* 4kW 5.5kW Contactors – Reversing AC3 rating 3ph 400/440V Number of contacts Main Auxiliary Catalogue numbers 3 N.O. 3 N.O. 1 N.O. 1 N.C. CE52BNC310* CE52BNC301* 3 N.O. 3 N.O. 1 N.O. 1 N.C. CE52CNC310* CE52CNC301* 4kW 5.5kW * Add suffix for coil voltage from the tables below A.C. operating coils - 3.5VA Coil voltage 40 to 450Hz 24 48 110 - 127 220 - 240 277 380 - 415 Suffix T W A B H L D.C. low power consumption operating coils for non-reversing contactors Coil voltage Suffix 24 (1.4 watts) 24 (1.7 watts with surge suppressor) 17 - 32 (2.4 watts) 17 - 32 (2.8 watts with surge suppressor) T2 T3 V2 V3 Can not be used when auxiliary contacts are fitted. D.C. operating coils - 3.5 watts Coil voltage 12 24 48 110 - 125 220 - 240 Suffix R1 T1 W1 A1 B1 www.eatonelectrical.com TDO3400001U Mini Series Contactors and Overload Relays April 2005 Mini Series – 4 and 5.5kW Catalogue numbers - Accessories Auxiliary Contacts ➀ Description Contact configuration Catalogue numbers Side mounting 1 N.O. 1 N.C. C320MCS11 Top mounting 1 N.O. 1 N.C. 2 N.O. 2 N.C. C320MCF11 C320MCF20 C320MCF02 Description Voltage Catalogue numbers Supressors 24 - 60Vdc 50 - 250Vdc 200 - 420Vdc C320MSS1 C320MSS2 C320MSS3 ➀ Top and side mounted auxiliary contact blocks can not be used together. Accessories Identification markers TDO3400001U C320MCM1 www.eatonelectrical.com 3 Mini Series Contactors and Overload Relays 4 April 2005 Mini Series – 4 and 5.5kW Technical data – Contactors Contactor CE12BN & CE52BN CE12CN & CE52CN Specifications IEC 947-4-1, IEC947-5-1 IEC947-4-1 Rated insulation voltage Ui 690V 500V Air temperature (close to contactor) Fitted with a thermal O/L relay 25 to +50¡C 25 to +50¡C Without thermal O/L relay 25 to +55¡ 25 to +55¡C For storage 40 to +80¡C 40 to +80¡C Climatic withstand Acc. to DIN 50 017 Acc. to UTE C 63-100 Humidity in alternative climate 30 cycles, specification 1 Humidity in alternative climate KFW 30 cycles, specification 1 Mounting positions All positions All positions Mechanical durability Operating cycles 10 million 10 million Maximum switching frequency AC-1 300 cycles/h 300 cycles/h DC-1, DC-3, DC-5, AC-2, AC-3, AC-15, DC-13 600 cycles/h Rated operational voltage Ue 12 - 500V ac Rated operational current Ie/AC-1, AC-3 Rated operational power at: AC-1/Ie (A) 55¡C 40¡C AC-2, AC-3 Ie (A) P (kW) AC-1/Ie (A) 55¡C 40¡C AC-2, AC-3 Ie (A) P (kW) 16 16 12 9 9/8 5.5 16 16 12 12/11 12/11 7.0 220/240V 380/440V 500V 12 - 500V ac 20 20 12 2.2 4.0 3.0 20 20 12 3 5.5 4 1/ sinusoidal shock for 10ms: 2 no change in contact position 1/ sinusoidal shock for 10ms: 2 no change in contact position Shock directions A B1 B2 C1 C2 A B1 B2 C1 C2 Making position Breaking position 20g 10g 20g 20g 20g 20g 20g 20g 20g 20g 20g 10g 20g 20g 20g 20g 20g 20g 20g 20g Shock withstand Standard mounting position: position 1 Operating time Between coil energisation and: N.O. contact closing/N.C. contact opening B6 14 - 26 BC6 (ms) 14 - 26 K6 (ms) 14 - 26 KC6 (ms) 14 - 26 B7 (ms) 14 - 26 BC7 (ms) (ms) 14 - 26 Between coil de-energisation and: N.O. contact opening/N.C. contact closing 16 - 40 4 - 10 16 - 40 4 - 10 16 - 40 4 - 10 Heat dissipation per pole 2W at 20A 2W at 20A Short-circuit protection (for contactors without add-on thermal O/L relay) Type fuses gG (gl) - co-ordination: Type 1 Type 2 20A 20A 25A 20A Coil consumption (average value) ac pull-in/holding dc pull-in/holding 3.5VA 3.5W 3.5VA 3.5W Technical data – Built-in or add-on auxiliary contact blocks Rated operational voltage Ue 12 - 240V dc 12 - 500V ac Conventional free air thermal current Ith 6A Short-circuit protection, type fuses gG (gl) 10A Rated operational current Ie / AC-15 220/240V 380/440V 500V 4A 3A 2A Rated operational current Ie / DC-13 24V 60V 110V 220/240V 1.5A 0.5A 0.4A 0.04 Min. switching capacity of auxiliary contacts ⊕ 17V and ⊕ 5mA www.eatonelectrical.com TDO3400001U Mini Series Contactors and Overload Relays 5 April 2005 Mini Series – 4 and 5.5kW Technical data AC Electrical endurance curves 4kW contactors – AC1 & AC3 duty 4kW contactors – AC4 duty 5.5kW contactors – AC1 & AC3 duty 5.5kW contactors – AC4 duty Electrical durability curves for DC-1, DC-3 & DC-5 DC power circuit switching The curves below take into account the time constant L/R for each utilisation category and show the electrical drability of the contactors during DC-1, DC-3 and DC-5 use for three poles connected in series. Utilisation category + – 24V 48V 60V 110V 220V 16A 16A 16A 7.0A 0.8A 16A 8.0A 4.0A 1.5A 0.25A 16A 2.0A 1.25A 0.4A 0.2A + – 24V 48V 60V 110V 220V 16A 16A 16A 16A 5.0A 16A 16A 15A 7.0A 1.5A 16A 16A 12A 2.0A 0.5A 24V 48V 60V 110V 220V 16A 16A 16A 16A 14A 16A 16A 16A 15A 4.0A 16A 16A 16A 8.0A 2.0A If one single pole is used, the corresponding breaking capacity (W) is reduced to 1/3 and for two poles connected in series it is reduced to 2/3. A = DC-1 3 poles in series B = DC-3 3 poles in series C = DC- 5 3 poles in series + TDO3400001U DC-1 DC-3 DC-5 L/R ⊕ 1ms L/R ⊕ 2ms L/R ⊕ 7.5ms www.eatonelectrical.com – 6 Mini Series Contactors and Overload Relays April 2005 Mini Series – 4 and 5.5kW Lighting circuit switching The table below shows the number of lamps per phase in 230V 50Hz for the main poles (terminals marked 1 to 8): Note that overshooting of the announced capacitive loads may generate on energisation unacceptable current peaks. Other factors may influence peak amplitude on energisation. ● ● ● Lengths and cross sections of installation conductors Electronic arcing devices Lamp maufacture For these reasons, the values in the following tables are given for information only. Type of lamps Characteristics In (W) (A) Number of lamps per phase (230V, 50Hz) Incandescent lamps 60 10 200 300 500 1000 20 12 6 4 2 1 Flourescent lamps Without compensation and series compensation 15 0.35 25 20 0.37 23 40 0.43 20 58 0.67 16 65 0.67 12 115 1.5 5 140 1.5 5 0.26 0.43 0.87 1.30 2.17 4.35 Two lamp circuit 2 x 20 1 x 0.13 2 x 40 1 x 0.22 2 x 58 1 x 0.32 2 x 65 1 x 0.34 2 x 115 1 x 0.65 2 x 140 1 x 0.75 2 x 26 2 x 20 2 x 16 2 x 12 2x5 2x5 Parallel compensation 15 0.11 7 20 0.13 6 40 0.22 7 58 0.32 5 65 0.34 4 115 1.65 1 140 1.75 1 High pressure mercury vapour lamps eg HQL, HPL 1 x 18 2 x 18 1 x 36 2 x 36 1 x 56 2 x 58 Type of lamps Characteristics In (W) (A) Metal Iodide lamps eg HGI, HPI Without compensation 35 0.53 10 70 1.0 5 150 1.8 3 250 3.0 2 400 3.5 1 4.5 4.5 4.5 7 7 18 18 7 8 10 18 25 45 60 Number of lamps per phase (230V, 50Hz) Parallel compensation 35 0.25 6 70 0.45 3 150 0.75 1 250 1.5 1 400 2.5 1 low pressure sodium lamps Dual mounting Without compensation 50 0.61 10 80 0.8 7 125 1.15 5 250 2.15 3 400 3.25 2 700 5.40 1 Parallel compensation 50 0.28 10 80 0.41 7 125 0.65 5 250 1.22 3 400 1.95 2 700 3.45 1000 4.8 Lamps with electronic ignition device Capacitive load in µF 17 8 11 6 11 6 www.eatonelectrical.com 20 20 30 45 40 40 25 Without compensation 150 1.8 3 250 3.0 2 330 3.7 2 400 4.7 1 Parallel compensation 150 0.83 250 1.5 330 2.0 400 2.4 1000 6.3 Transformers for low voltage halogen lamps 6 12 20 33 35 Without compensation 35 1.5 4 55 1.5 4 90 2.4 2 135 3.5 2 150 1.0 2 180 3.3 2 200 2.3 2 Parallel compensation 35 0.31 55 0.42 90 0.63 135 0.94 150 1.0 180 1.16 200 1.32 High pressure sodium lamps Capacitive load in µF 20 33 40 48 106 Transformer power (W) Number of transformers per phase (230V, 50Hz) 20 50 75 100 150 200 300 40 20 13 10 7 5 3 TDO3400001U Mini Series Contactors and Overload Relays April 2005 Mini Series – Overload Relay Catalogue numbers Motor FLA in Amperes .10 – .16 .16 – .24 .24 – .40 .40 – .60 .60 – 1.00 1.00 – 1.60 1.60 – 2.40 2.40 – 4.0 4.0 – 6.0 6.0 – 9.0 9.0 – 12.0 Catalogue Number C312AN3A C312AN3B C312AN3C C312AN3D C312AN3E C312AN3F C312AN3G C312AN3H C312AN3J C312AN3K C312AN3L Overload relays to be used with Pressure Plate Terminal type Mini Contactors only. Technical data ¥ ¥ Thermal Overload Relay C312 — Conformity to Standards ¥ IEC 947-4-1, 947-5-1, CE ¥ UL 508, CSA 22.2 ¥ Thermal (Bimetallic) Overload Relay, C312 OL Relay ¥ Insulation Voltage (Ui): 690V AC ¥ Rated Operational Voltage (Ue): 690V AC ¥ Ambient Temperature: -13° to 122°F (-25° to +50°C) temperature compensated ¥ Storage: -40° to 158°F (-40° to +70°C) ¥ ¥ ¥ ¥ ¥ Impulse Withstand Voltage (Uimp): 6 kV Climatic Resistance — ¥ Acc. to DIN 50 017 ¥ Acc. to UTE C 63 – 100: IEC 68-2-3, IEC 68-2-30 Mounting Position: ± 30 from vertical position, not horizontal, not upside down, 5 mm side by side mounting distance Switching Frequency with Avoidance of Nuisance Trippings — max. ops./h: 15 40% ED — max. ops./h: 60 (if 6X in startup time 1 s) Overvoltage Category/Pollution Degree: III/3 Safe Isolation to IEC 536: 300V AC Conventional Free Air Thermal Current (Ith): 6.0A Terminal Capacities Description Solid Flexible with Ferrule Solid or Stranded Specification mm 2X (.75X – 2.5) mm mm 2X (.5X – 1.5) mm AWG 2X (18X –12) Trip Contact Ratings AC-15 Operating Voltage (Ue) Rated Operational Current (Ie) Contacts 95 – 96 — NC (Break) Contacts 97 – 98 — NO (Make) 120V 220/240V 380/415V 500V – – 1.5A 1.5A .7A .5A .5A .3A 24V DC 60V DC 110V DC 220V DC .9A .9A .5A .5A .3A .3A .1A .1A Trip Contact Ratings DC-13 Operating Voltage (Ue) Rated Operational Current (Ie) Contacts 95 – 96 — NC (Break) Contacts 97 – 98 — NO (Make) Setting Variances TDO3400001U www.eatonelectrical.com 7 8 Mini Series Contactors and Overload Relays April 2005 Mini Series – 4 and 5.5kW Dimensions (mm) Contactor Reversing contactors Contactor with side mounted auxiliary Contactor with top mounted auxiliary Mounting dimensions www.eatonelectrical.com TDO3400001U Mini Series Contactors and Overload Relays April 2005 Mini Series – 4 and 5.5kW Dimensions (mm) Mini contactor and overload relay Side mounted auxiliary contact TDO3400001U Top mounted auxiliary contact www.eatonelectrical.com 9 10 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Catalogue numbers – Contactors AC3 rating 3 ph 380/440V (kW) Number of contacts Main Auxiliary Catalogue numbers AC operated DC operated 2.2 3 N.O. 3 N.O. 4 N.O. 1 N.O. 1 N.C. CE15ANS3* CE15ANC3* CE15AN4* – – – 4 3 N.O. 3 N.O. 4 N.O. 1 N.O. 1 N.C. CE15BNS3* CE15BNC3* CE15BN4* CE15BNS3* – – 5.5 3 N.O. 3 N.O. 4 N.O. 1 N.O. 1 N.C. CE15CNS3* CE15CNC3* CE15CN4* CE15CNS3* – – 7.5 11 15 3 N.O. 3 N.O. 3 N.O. CE15DN3* CE15EN3* CE15FN3* CE15DNS3* CE15ENS3* CE15FNS3* 18.5 22 30 37 3 N.O. 3 N.O. 3 N.O. 3 N.O. CE15GN3* CE15HN3* CE15JN3* CE15KN3* CE15GNS3* CE15HNS3* CE15JNS3* CE15KNS3* 45 55 75 3 N.O. 3 N.O. 3 N.O. 1 N.O. 1 N.O. 1 N.O. CE15LN3* CE15MN3* CE15NN3* CE15LNS3* CE15MNS3* CE15NNS3* 90 110 160 3 N.O. 3 N.O. 3 N.O. 1 N.O. 1 N.C. 1 N.O. 1 N.C. 1 N.O. 1 N.C. MCE15PN3* MCE15RN3* MCE15SN3* MCE15PNS3* MCE15RNS3* MCE15SNS3* * Add suffix from tables on page 11 to select coil voltage required. For voltages not shown contact Head Office. Mounting positions of auxiliary contacts Contactors CE15LN to NN are supplied with R1 fitted. Contactors CE15PN to SN with ac coils are supplied with L1 fitted. With dc coils L1 and L2 are fitted. By attaching combinations of top and side mounted auxiliary contact blocks up to 8 additional circuits may be added. CE15AN to CE15KN up to 8 N.O. or 4 N.O. - 4 N.C. CE15LN to CE15SN maximum 6 N.O. or 6 N.C. in any one configuration www.eatonelectrical.com TDO3400001U Freedom Series Contactors and Overload Relays 11 April 2005 Freedom Series – 2.2 to 160kW Catalogue numbers – Accessories Auxiliary contact blocks – top mounting (maximum 1 per contactor) Contact configuration Contactor type 1 N.O. Catalogue numbers CE15A to CE15K C320KGT1 C320KGT2 C320KGT3 C320KGT4 C320KGT5 C320KGT15 C320KGT14 C320KGT13 1 N.C. 1 N.C. 1 N.O. 2 N.O. 2 N.C. 2 N.C. 1 N.C. 2 N.O. 3 N.O. 4 N.O. Auxiliary contact blocks – side mounting (maximum 2 per contactor) Contact configuration Mounting position ✝ 1 N.O. L1, R1 L1, R1 L1, R1 L1, R1 1 N.C. 1 N.C. 1 N.O. 2 N.O. Contactor type Catalogue numbers CE15AN to KN C320KGS1 C320KGS2 C320KGS3 C320KGS4 Contactor type Catalogue numbers Auxiliary contact blocks – base mounting Contact configuration 1 N.O. 1 N.O. 1 N.O. 1 N.O. Mounting position ✝ L1, R1 L1, R1 L1, R1 L1, R1 1 N.C. 1 N.C. CE15LN to NN CE15LN to NN CE15PN to SN CE15PN to SN C320KGS31 C320KGS32 C320KGS41 C320KGS42 Auxiliary contact blocks – add-on Contact configuration 1 N.O. 1 N.C. 1 N.C. 1 N.O. Mounting position ✝ Contactor type Catalogue numbers L2, L3, R2, R3 L2, L3, R2, R3 L2, L3, R2, R3 CE15LN to SN C320KGS20 C320KGS21 C320KGS22 ✝ Mounting postions of auxiliary contacts (See page 33) A.C. Operating coils Coil 50Hz voltage 60Hz 24 - 48 - 110 120 220 240 240 - 380 - 415 - 440 480 550 600 Suffix CE15AN to FN T code Y A B K L M C D CE15GN to SN U Y A B K L M C D D.C. operating coils for contactors 4 to 15 & 45kW to 75kW only D.C. Operating coils for contactors 90 to 160kW only Coil voltage 12 24 48 120 Coil voltage 24 48 120 240 Suffix code R1B T1B W1B A1B Suffix code T1B W1B A1B B1B D.C. Operating coils for contactors 18.5 to 37kW only Coil voltage 12 24 48 120 Suffix code R4B T4B W4B A4B D.C. Coil elementary diagram for contactors 4 to 15kW Note DC operating coils come complete with encapsulated coil, 1N.C. early opening side auxiliary and connection wiring. TDO3400001U www.eatonelectrical.com 12 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Catalogue numbers – Accessories (continued) Description For contactor type Pneumatic timer – top mounting Adjustable range (On or off delay) 0.3 to 30 secs. 10 to 180 secs. Catalogue numbers CE15AN to KN C320TP1 C320TP2 Note: When timer is used, other top mounting auxiliaries cannot be added. Mechanical interlock When fitted, auxiliary contacts can be added to one side of the contactor only. C321M60B CE15AN to KN C321KM60B CE15LN to NN C321KM30 MCE15PN to SN C321KM40 C321KM30 Coil surge suppressor To suppress operating coil switch-off surge. Control supply 50-60Hz 24 48V 110 240V 110 240V 110 240V CE15AN to KN CE15AN to KN CE15LN to NN MCE15PN to SN MC320LRC5 MC320LRC2 MC320LRC3 MC320LRC3 1 metre length CE15AN to GN MC382MA1 Pack of 100 CE15AN to KN C320DL2 CE15AN to CN CE15DN to FN CE15GN to KN CE15LN to NN MCE15PN to SN C321KM60K14B C321KM60K13B C321KM60K16B C321KM60K21 ✝ C321KM60K19 ✝ CE15LN to NN C325MTK MCE15PN to SN MC321TE3 Standard mounting Side mounting Side mounting with overload relay fitted CE15LN to NN MC321FK1 MC321FK2 MC321FK3 Standard or side mounting with or without overload relay fitted MCE15PN to SN 35mm DIN mounting rail Identification marker Reversing connections kit Comprises mechanical interlock and a pre-cut trimmed and formed wire set. Termination kits for main contacts For crimp terminal lugs to allow connection of up to 2 additional cables for reversing or star/delta duty. Extension plates for reversing connections. Finger protection shields Shields to prevent accidental contact with line/load terminals. MC321FK4 ✝ Kit includes 2 off N.C. auxiliary contact blocks. www.eatonelectrical.com TDO3400001U Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Catalogue numbers – Accessories (continued) Description For contactor type Catalogue numbers CE15GN3 CE15HN3 CE15JN3 CE15KN3 CE15LN3 CE15MN3 CE15NN3 CE15NN MCE15PN MCE15RN MCE15SN 6-65-4 6-65-6 6-65-8 6-65-17 6-43-4 6-43-2 6-43-6 6-293 6-294 6-288 6-286 Main contact renewal kit Replacement operating coils – AC (See note below) Coil voltage 50Hz 60Hz Catalogue numbers CE15AN to CN CE15DN to FN CE15GN to KN CE15LN to NN MCE15PN to SN 24 48 110 220 240 380 415 440 550 MC15CWU MC15CWY MC15CWA MC15CWB MC15CWK MC15CWL MC15CWM MC15CWC MC15CWD MC15FWU MC15FWY MC15FWA MC15FWB MC15FWK MC15FWL MC15FWM MC15FWC MC15FWD MC15KWU MC15KWY MC15KWA MC15KWB MC15KWK MC15KWL MC15KWM MC15KWC MC15KWD MC15WU MC15WY MC15WA MC15WB MC15WK MC15WL MC15WM MC15WC MC15WD 9-2412-5A 9-2412-8A 9-2412-1A 9-2412-2A 9-2412-13A 9-2412-14A 9-2412-16A 9-2412-3A 9-2412-4A 120 240 480 600 Note: Replacement operating coils are for use with current series 'B' contactors. For replacement coils for previous series 'A' contactors please contact Eaton. TDO3400001U www.eatonelectrical.com 13 14 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Catalogue numbers – Thermal overload relays For direct connection with CE15AN to FN contactors or independent mounting Description Relay with 1 N.O. 1 N.C. electrically separate contacts, selectable hand or auto reset with reset or stop-reset option, phase loss protection and trip indicator. Motor FLC range A 0.25 0.4 0.63 1.0 1.3 1.7 2.2 2.8 3.5 4.5 6.0 7.5 10 13 18 24 0.4 0.63 1.0 1.4 1.8 2.4 3.1 4.0 5.0 6.5 8.5 11.0 14.0 19.0 24.0 32.0 Separate base for independent connection and DIN rail or panel mounting Catalogue numbers C316FNA3C C316FNA3D C316FNA3E C316FNA3F C316FNA3G C316FNA3H C316FNA3J C316FNA3K C316FNA3L C316FNA3M C316FNA3N C316FNA3P C316FNA3Q C316FNA3R C316FNA3S C316FNA3T C306TB1 For direct connection with CE15GN to KN contactors or independent mounting Relay with 1 N.O. 1 N.C. electrically separate contacts, selectable hand or auto reset with reset or stop-reset option, phase loss protection and trip indicator. 18 22 29 36 45 60 25 32 42 52 63 80 Separate base for independent connection and panel mounting C316KNA3A C316KNA3B C316KNA3C C316KNA3D C316KNA3E C316KNA3F C316TB1 Note: For star-delta applications multiply motor FLC by 0.58 www.eatonelectrical.com TDO3400001U Freedom Series Contactors and Overload Relays 15 April 2005 Freedom Series – 2.2 to 160kW Catalogue numbers – Thermal overload relays (continued) For independent mounting and connection with CE15LN to PN contactors Description Relay with 1 N.O. 1 N.C. electrically separate contacts, selectable hand or auto reset with reset or stop-reset option, phase loss protection and trip indicator. Motor FLC range A 65 90 80 110 100 135 110 150 130 175 150 200 Set of connecting links To contactors CE15LN to NN3 To contactors CE15PN Catalogue numbers C316PNA3A C316PNA3B C316PNA3C C316PNA3D C316PNA3E C316PNA3F C316MCL C316PCL Current transformer operated for independent connection with CE15RN to SN contactors Relay with 1N.O. 1N.C. electrically separate contacts, selectable hand or auto reset with reset or stop-reset option, phase loss protection and trip indicator. 130 185 165 235 220 310 285 400 Identification marker (pack of 50) C316SNA3A C316SNA3B C316SNA3C C316SNA3D C316MT1 Remote reset module Description Operating voltage 50/60HZ Catalogue numbers For use with thermal overload relays C316FNA3, and C316SNA3 220/440 C316RR1N Operating time Minimum: 0.2 secs Maximum: 0.3 secs Inrush VA Operating voltage 220/440 Note: For star-delta applications multiply motor FLC by 0.58 TDO3400001U www.eatonelectrical.com Inrush VA 412 16 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Type 2 co-ordination selection procedure Step 1. Step 4. Determine the motor Full Load Current (FLC) from Table 1. Select overload relay and note it's fuse link rating from table 4. Table 4. Eaton Freedom Series overload relays Step 2. Decide method of starting and then note the fuse link rating which corresponds to the Motor FLC from table 2a (Direct on Line) or 2b (Star Delta starting). Step 5. Compare the fuse link rating noted in step 2 with the lowest of the ratings noted in steps 3 and 4. Example Step 2 - Motor = 16A Step 3 - Contactor = 16A Step 4 - Overload relay = 20A If this lowest value is less than the fuse link rating noted in step 2, then Type 2 co-ordination is not achieved. Step 3. Select contactor and note it's fuse link rating from table 3. If this lowest value is equal to or greater than the fuse link rating noted in step 2, then Type 2 co-ordination is achieved. NO Type 2 Co-ordination is not achieved. YES Type 2 Co-ordination is achieved. Table 4. Eaton Freedom Series contactors www.eatonelectrical.com TDO3400001U Freedom Series Contactors and Overload Relays 17 April 2005 Freedom Series – 2.2 to 160kW Selection procedure (continued) Table 1. Motor full load current Table 2a. D.O.L. fuse link rating Table 2b. Star/delta fuse link rating kW HP 220V 380V 415V Motor FLC (A) Fuse (A) Motor FLC (A) Fuse (A) 1.1 1.5 2.2 3.0 4.0 5.5 7.5 10 11 15 18.5 22 30 37 45 55 75 90 110 132 160 1.0 2.0 3.0 4.0 5.5 7.5 10 13.5 15 20 25 30 40 50 60 75 100 125 150 175 220 4.9 6.3 9.0 12 16 21 27 36 40 52 64 77 100 125 150 180 240 300 350 410 510 2.9 3.6 5.2 6.8 9.1 12 16 21 23 30 37 44 59 73 86 106 140 170 200 240 300 2.6 3.3 4.8 6.2 8.3 11 14 19 21 28 34 41 54 67 79 98 130 160 190 220 270 0 0.8 1.5 2.1 3.1 6.2 9.1 11.1 14.5 15.5 18.1 22.1 28.1 45.1 58.1 80.1 99.1 128 180 216 2 4 6 10 16 20 25 32 35 40 50 63 80 100 125 160 200 250 315 355 0 1.5 2.2 3.2 5.6 10.1 14.1 18.1 22.1 28.1 32.1 40.1 51.1 80.1 100 125 160 200 250 315 2 4 6 10 16 20 25 32 35 40 50 63 80 100 125 160 200 250 315 355 Table 3. Freedom contactors - 0.7 1.4 2.0 3.0 6.1 9.0 11 14.4 15.4 18 22 28 45 58 80 99 128 180 216 270 - 1.4 2.1 3.1 5.5 10 14 18 22 28 32 40 51 80 100 125 160 200 250 315 355 Table 4. Freedom overload relays kW le (AC3) 380/415V Contactor cat. no. Fuse (A) Full load current range (A) Catalogue number Fuse (A) Full load current range (A) Catalogue number Fuse (A) 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 160 5.2 9.1 12 16 23 30 37 44 59 73 86 106 140 170 200 300 CE15A CE15B CE15C CE15D CE15E CE15F CE15G CE15H CE15J CE15K CE15L CE15M CE15N MCE15P MCE15R MCE15S 16 25 32 35 50 63 100 100 125 125 160 200 250 250 315 355 0.25 0.4 0.43 1.0 1.3 1.7 2.2 2.8 3.5 4.5 6.0 7.5 10 13 18 24 C316 FNA3C FNA3D FNA3E FNA3F FNA3G FNA3H FNA3J FNA3K FNA3L FNA3M FNA3N FNA3P FNA3Q FNA3R FNA3S FNA3T 2 2 4 4 6 10 10 16 20 20 25 32 35 50 50 80 18 22 29 36 45 60 65 80 100 110 130 150 130 165 220 285 355 465 610 C316 KNA3A KNA3B KNA3C KNA3D KNA3E KNA3F C316 PNA3A PNA3B PNA3C PNA3D PNA3E PNA3F C316 SNA3A SNA3B SNA3C SNA3D C316 UNA3A UNA3B UNA3C 50 63 80 125 160 200 200 200 200 250 315 315 - 0.4 0.63 1.1 1.4 1.8 2.4 3.1 3.1 5.0 6.5 8.5 11 14 19 24 32 - 25 32 42 52 63 80 90 110 135 150 175 200 185 235 310 400 500 650 850 C/T overload relays No limit Notes: 1. Account of the crossover current (Ic) of the fuse and the overload relay characteristic has already been made in the formation of table 4. 3. Remember all testing has been conducted at 415 Volts. Co-ordination details are therefore applicable at this voltage or lower. 2. A thermal or electronic overload relay which uses current transformers to sense primary current, has no restriction on the size of fuse required to afford Type 2 co-ordination. Determination of the maximum fuse size should be based on co-ordination of the contactor as shown in table 3. 4. Reference should be made to the Contactor Safety Perimeter Zone dimensions (page 38) to ensure that within the enclosure used, no part of the metal work infringes this zone. TDO3400001U www.eatonelectrical.com 18 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Technical data Contactor CE15AN CE15BN CE15CN CE15DN General kW AC3 rating 380/415V 2.2 4.0 5.5 7.5 Standards and approvals IEC947-4-1, UL508, CSA22.14 Width mm 45 45 45 45 Number of poles (maximum) 4 4 4 3 Protection against direct contact (with terminal cover fitted) IP20 to IEC529 (removable terminal cover) Mechanical lifespan 20,000,000 20,000,000 20,000,000 20,000,000 Weight kg 0.41 0.41 0.41 0.44 3 Environment Pollution degree IEC947-1 3 3 3 Impulse withstand voltage IEC947-4-1 6kV 6kV 6kV Operating temperature, open 20 to +65¡C Relative humidity at 40¡C 95% 95% 95% 95% Operating altitude 2,000m 2,000m 2,000m 2,000m Operating position (relative to normal mounting position) ±30¡ ±30¡ ±30¡ ±30¡ 690V Main contact ratings Insulating voltage Ui 20 to +65¡C 6kV 20 to +65¡C 20 to +65¡C 690V 690V 690V Operating frequency limits 50 to 60Hz 50 to 60Hz 50 to 60Hz 50 to 60Hz Rated thermal current Ith @ 600V 20 20 20 32 AC1 duty Rated operational current Ie (A) Maximum power rating P (kW) (p.f.) = 0.8 Non-inductive or slightly inductive loads AC2 & AC3 duty Rated operational current Ie (A) Maximum power rating P (kW) Slipring motors: Starting, switching off Squirrel cage motors: Starting, plugging & inching P 220/240V 380/415V 440/460V 500/575V 660V 220/240V 380/415V 440/460V 500/575V 660V Ie 6.1 10.5 12.1 13.8 18.2 P Ie 6.1 10.5 12.1 13.8 18.2 P Ie 6.1 10.5 12.1 13.8 18.2 P P Ie P Ie P Ie P Ie 1.1 2.2 2.2 4.0 2.2 5.2 5.2 4.8 6.9 3.0 1.5 4.0 4.0 5.5 4.0 6.8 9.1 7.8 9.4 5.2 2.2 5.5 5.5 7.5 5.5 9.6 12.0 11.0 12.0 7.1 4.0 7.5 7.5 11.0 7.5 16.0 16.0 14.0 17.0 9.1 Maximum operations per hour 600 600 600 600 AC3 electrical life at 380/415V 2,800,000 2,300,000 2,100,000 1,500,000 AC2 electrical life at 380/415V 260,000 239,000 175,000 AC4 duty Rated operational current Ie (A) Maximum power rating P (kW) Squirrel cage motors: Starting, plugging & inching 220/240V 380/415V 440/460V 500/575V 660V Ie P Ie P Ie P Ie 1.1 2.2 2.2 4.0 2.2 5.2 5.2 4.8 6.9 3.0 1.5 4.0 4.0 5.5 4.0 6.8 9.1 7.8 9.4 5.2 2.2 5.5 5.5 5.5 5.5 9.6 12.0 11.0 9.4 7.1 4.0 7.5 7.5 7.5 7.5 16.0 16.0 14.0 12.0 9.1 300 AC4 electrical life at 380/415V 64,000 Rated operational current Ie (A) Maximum power rating P (kW) Ratings for contactors delta connected Rotor circuit contactors 220/240V 380/415V 440/460V 500/575V 660V 272,000 P Maximum operations per hour Other ratings Star delta starter duty 300 300 59,000 300 43,000 67,000 P IL P IL P IL P IL 2.2 5.5 5.5 7.5 4.0 9.6 12.0 11.0 12.0 4.0 4.0 7.5 7.5 7.5 5.5 16.0 16.0 14.0 12.0 5.5 4.0 11.0 11.0 11.0 7.5 16.0 23.0 21.0 17.0 7.5 7.5 15.0 15.0 18.5 11.0 28.0 30.0 27.0 28.0 11.0 Rated rotor insulation voltage Uir 690V 690V 690V Rated rotor operational voltage Uer 1320V 1320V 1320V 1320V 12A 15A 19A 27A 16A 21A 26A 36A 21A 27A 33A 46A 29A 38A 47A 66A AC2 duty, slipring motors starting and switching off Electrical life span > = 1,000,000 operations Ratings for contactors delta connected 100% DF 60% DF 40% DF 20% DF Ie 9.7 16.8 19.5 22 29 www.eatonelectrical.com 690V TDO3400001U Freedom Series Contactors and Overload Relays 19 April 2005 Freedom Series – 2.2 to 160kW CE15EN CE15FN CE15GN CE15HN CE15JN CE15KN 11.0 15.0 18.5 22.0 30.0 37.0 45 45 65 65 65 65 3 3 3 3 3 3 IEC947-4-1, UL508, CSA22.14 . Finger and back of hand protection to VDE0106 part 100. 20,000,000 20,000,000 10,000,000 10,000,000 10,000,000 10,000,000 0.44 0.44 1.25 1.25 1.25 1.25 3 3 3 3 3 3 6kV 6kV 6kV 6kV 6kV 20 to +65¡C 20 to +65¡C 20 to +65¡C 20 to +65¡C 6kV 20 to +65¡C 20 to +65¡C 95% 95% 95% 95% 95% 95% 2,000m 2,000m 2,000m 2,000m 2,000m 2,000m ±30¡ ±30¡ ±30¡ ±30¡ ±30¡ ±30¡ 690V 690V 690V 690V 690V 690V 50 to 60Hz 50 to 60Hz 50 to 60Hz 50 to 60Hz 50 to 60Hz 50 to 60Hz 32 32 50 60 75 80 P Ie 9.7 16.8 19.5 22.0 29.0 P Ie 9.7 16.8 19.5 22.0 29.0 P Ie 15.2 26.3 30.5 38.1 45.7 P Ie 18.3 31.6 36.6 45.7 54.9 P Ie 22.9 39.5 45.7 57.2 68.6 P Ie 24.4 42.1 48.8 61.0 73.2 P le P le P le P le P le P le 5.5 11.0 11.0 15.0 11.0 22.0 23.0 21.0 23.0 13.0 7.5 15.0 15.0 18.5 15.0 28.0 30.0 27.0 28.0 17.0 10.0 18.5 18.5 22.0 11.0 36.0 37.0 34.0 34.0 13.0 11.0 22.0 22.0 30.0 15.0 42.0 44.0 40.0 45.0 17.0 15.0 30.0 30.0 30.0 18.5 54.0 59.0 52.0 45.0 21.0 18.5 37.0 37.0 37.0 22.0 68.0 73.0 65.0 55.0 26.0 600 600 600 600 600 600 1,500,000 1,700,000 1,100,000 1,300,000 1,500,000 1,300,000 211,000 199,000 235,000 252,000 138,000 98,000 P le P le P le P le P le P le 5.5 11.0 11.0 11.0 7.5 22.0 23.0 21.0 17.0 9.1 5.5 11.0 11.0 11.0 7.5 22.0 23.0 21.0 17.0 9.1 10.0 18.5 18.5 22.0 11.0 36.0 37.0 34.0 34.0 13.0 11.0 22.0 22.0 30.0 15.0 42.0 44.0 40.0 45.0 17.0 15.0 30.0 30.0 30.0 18.5 54.0 59.0 52.0 45.0 21.0 15.0 30.0 30.0 30.0 18.5 54.0 59.0 52.0 45.0 21.0 600 600 52,000 600 75,000 600 58,000 600 62,000 600 34,000 34,000 P IL P IL P IL P IL P IL P IL 7.5 18.5 18.5 22.0 18.5 28.0 37.0 34.0 34.0 13.5 11.0 22.0 22.0 30.0 22.0 42.0 44.0 40.0 45.0 22.0 15.0 30.0 30.0 37.0 18.5 54.0 59.0 52.0 55.0 18.5 18.5 37.0 37.0 45.0 22.0 68.0 73.0 65.0 66.0 22.0 22.0 45.0 45.0 45.0 30.0 80.0 86.0 77.0 66.0 30.0 30.0 55.0 55.0 55.0 37.0 104.0 106.0 96.0 81.0 37.0 690V 690V 690V 690V 690V 1320V 1320V 1320V 1320V 1320V 1320V 40A 51A 63A 89A 52A 67A 82A 116A 64A 83A 101A 143A 76A 98A 120A 170A 104A 134A 164A 232A 126A 163A 200A 283A TDO3400001U www.eatonelectrical.com 690V 20 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Technical data (continued) Contactor CE15LN CE15MN CE15NN General kW AC3 rating 380/415V 45 55 75 Standards and approvals IEC947-4-1, UL508, CSA 22.14 Width mm 90 90 93 Number of poles 3 3 3 Mechanical lifespan 6,000,000 6,000,000 6,000,000 Weight kg 3.8 3.8 3.8 3 Environment Pollution degree IEC 947-1 3 3 Impulse withstand voltage IEC 947-4-1 6kV 6kV Operating temperature, open 20 to +65¡C Relative humidity 95% 95% 95% Operating altitude 2,000m 2,000m 2,000m Operating position (relative to normal mounting position) ±30¡ ±30¡ ±30¡ 690V Main contact ratings Insulation voltage Ui 6kV 20 to +65¡C 20 to +65¡C 690V 690V Operating frequency limits 50 to 60Hz 50 to 60Hz 50 to 60Hz Rated thermal current lth @ 600V 100 135 175 AC1 duty Rated operational current le (A) Maximum power rating P (kW) (p.f.)=0.8 Non-inductive or slightly inductive loads AC2 & AC3 duty Rated operational current le (A) Maximum power rating P (kW) Slipring motors: Starting, switching off Squirrel cage motors: Starting, plugging & inching P 220/240V 380/415V 440/460V 500/575V 660V 220/240V 380/415V 440/460V 500/575V 660V Ie 30 52 60 69 91 P Ie 41 71 82 93 123 P P le P le P le 22 45 45 55 37 86 86 86 81 42 30 55 55 75 45 106 106 106 106 50 37 75 75 75 45 140 140 140 105 50 Maximum operations per hour 600 600 600 AC3 electrical life at 380/415V 500,000 576,000 620,000 AC2 electrical life at 380/415V 121,000 125,000 AC4 duty Rated operational current le (A) Maximum power rating P (kW) Squirrel cage motors:Starting, plugging & inching 220/240V 380/415V 440/460V 500/575V 660V le P le P le 18.5 37 37 37 30 68 73 65 55 30 22 45 45 45 37 86 86 86 66 42 30 55 55 55 40 106 106 106 81 46 300 300 AC4 electrical life at 380/415V 39,000 43,000 Rated operational current le (A) Maximum power rating P (kW) Ratings for contactors delta connected Rotor circuit contactors 220/240V 380/415V 440/460V 500/575V 660V 160,000 P Maximum operations per hour Other ratings Star delta starter duty 300 61,000 P IL P IL P IL 45 75 75 90 55 150 140 130 130 55 55 90 90 132 75 180 170 160 180 75 75 132 132 132 75 240 240 220 180 75 Rated rotor insulation voltage Uir 690V 690V 690V Rated rotor operational voltage Uer 1320V 1320V 1320V 165A 213A 261A 369A 225A 290A 356A 503A 330A 426A 522A 738A Slipring motors starting and switching off Electrical life span >=500.000 operations at 100% DF Ratings for contactors delta connected 100% DF 60% DF 40% DF 20% DF Ie 45 79 91 104 137 www.eatonelectrical.com TDO3400001U Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW MCE15PN MCE15RN MCE15SN 90 110 160 IEC947-4-1, UL508, CSA22.14 178 178 178 3 3 3 5,000,000 5,000,000 5,000,000 8.25 8.3 8.3 3 3 3 6kV 6kV 6kV –20 to +65°C –20 to +65°C –20 to +65°C 95% 95% 95% 2,000m 2,000m 2,000m ±30° ±30° ±30° 690V 690V 690V 50 to 60Hz 50 to 60Hz 50 to 60Hz 185 220 315 IP Ie 56 97 112 128 169 P Ie 67 115 134 152 200 P Ie 96 165 192 218 288 P le P le P le 45 90 90 90 45 170 170 170 130 50 55 110 110 110 55 200 200 200 160 61 90 160 160 160 75 300 300 300 210 80 600 600 300 582,000 520,000 351,000 173,000 166,000 100,000 P le P le P le 37 65 65 65 45 128 128 128 98 50 45 75 75 75 55 150 140 140 105 61 50 90 90 90 75 170 170 170 160 80 300 200 150 67,000 65,000 60,000 P IL P IL P IL 75 132 160 132 75 240 240 220 180 75 110 200 220 160 90 380 380 380 225 90 160 250 300 220 110 520 520 485 320 110 690V 690V 690V 1320V 1320V 1320V 357A 461A 564A 798A 393A 507A 621A 879A 465A 600A 735A 1040A TDO3400001U www.eatonelectrical.com 21 22 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Contactor CE15AN CE15BN CE15CN CE15DN Non motor utilisation categories AC-5a Switching of electrical discharge lamps. Ue<=440V, rated current le le le le le 18A 25A 25A 32A 3A 4A 5.2A 7.3A 3.1A 4.2A 5.4A 7.6A AC-5b Switching of incandescent loads. Ue<=575V, rated current le AC-6a Switching of transformers. Having inrush current peaks not more than 30 times peak of the rated current. Ue<=575V, rated current le AC-6b Switching of single capacitor banks. Having prospective short circuit current Ik at the location of the capacitor bank. Ue<=575V Ik<=15kA Where Ik is between 15kA and 25kA, derate to 60% of the ratings. Where Ik is between 25kA and 50kA, derate to 30% of the ratings. Ue kVAr Ie kVAr Ie kVAr Ie kVAr Ie 220V 380V 415V 440V 500V 550V 575V 2.6 4.5 4.9 5.2 5.9 6.5 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 3.5 6.1 6.7 7.1 8.1 8.9 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 4.6 7.9 8.6 9.1 10.0 11.0 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 6.5 11.0 12.0 13.0 14.0 16.0 15.0 15.1 15.1 15.1 15.1 15.1 15.1 15.1 Average contact resistance per pole (milli-ohms) 2 2 2 1.3 Power dissipated per pole at lth, W 0.8 0.8 0.8 1.3 Power dissipated per pole at le max, W 0.1 0.18 0.29 0.38 Short circuit co-ordination; IEC947-4 Type 2 Type 2 Type 2 Type 2 Circuit breaker type A305 6.3 – 9 9 – 12.5 9 – 12.5 16 – 20 Fuse type: BS88 class gG & gM 16A 25A 32A 35A Rated conditional short circuit current (Iq) 50kA 50kA 50kA 50kA >=0.85 <=1.1Uc >=0.85 <=1.1Uc >=0.85 <=1.1Uc >=0.85 <=1.1Uc Drop out >=0.2 <=0.75Uc >=0.2 <=0.75Uc >=0.2 <=0.75Uc >=0.2 <=0.75Uc Pick up VA 70 70 70 92 Sealed VA 6.4 6.4 6.4 8 Sealed W 1.9 1.9 1.9 2.7 Duty (continuous rated) maximum rate of operation 12,000 12,000 12,000 12,000 Insulation class of coil to IEC85 (BS2757) B B B B Pick up time 16 16 16 16 Magnet system – AC operated Pickup Drop out time Magnet system – DC operated Pickup VA/W Sealed VA/W 12 12 12 12 Coil voltage 12V 24V 48V 120V – – – – 6.4/76.8 3.2/76.8 1.6/76.8 0.64/76.8 6.4/76.8 3.2/76.8 1.6/76.8 0.64/76.8 6.4/76.8 3.2/76.8 1.6/76.8 0.64/76.8 12V 24V 48V 120V – – – – 0.28/3.36 0.14/3.36 0.07/3.36 0.028/3.36 0.28/3.36 0.14/3.36 0.07/3.36 0.028/3.36 0.28/3.36 0.14/3.36 0.07/3.36 0.028/3.36 Cabling capacity in accordance with the requirements of EN 60 947 Number of conductors 2 2 2 2 Solid or stranded – Max. wire size (mm2) – Min. wire size (mm2) 2.5 0.75 2.5 0.75 2.5 0.75 6 1 Flexible – Max. wire size (mm2) – Min. wire size (mm2) 2.5 0.75 2.5 0.75 2.5 0.75 4 1 Cabling maximum terminal capacity Number of conductors Solid, stranded or flexible. Max. size (mm2) 2 2 2 2 4 4 4 10 www.eatonelectrical.com TDO3400001U Freedom Series Contactors and Overload Relays 23 April 2005 Freedom Series – 2.2 to 160kW CE15EN CE15FN CE15GN CE15HN CE15JN CE15KN le le le le le le 32A 32A 50A 60A 75A 80A 10A 12A 14.6A 19A 19A 24A 10A 13A 15A 20A 20A 24A kVAr Ie kVAr Ie kVAr Ie kVAr Ie kVAr Ie kVAr Ie 8.4 14.0 15.0 16.0 19.0 21.0 20.3 20.4 20.4 20.4 20.4 20.4 20.4 20.4 8.4 14.0 15.0 16.0 19.0 21.0 26.5 26.6 26.6 26.6 26.6 26.6 26.6 26.6 13.0 23.0 25.0 26.0 30.0 33.0 32.7 32.8 32.8 32.8 32.8 32.8 32.8 32.8 16.0 27.0 30.0 32.0 36.0 40.0 39.7 39.9 39.9 39.9 39.9 39.9 39.9 39.9 19.0 34.0 37.0 39.0 45.0 49.0 53.0 53.2 53.2 53.2 53.2 53.2 53.2 53.2 21.0 36.0 40.0 42.0 48.0 53.0 64.5 64.7 64.7 64.7 64.7 64.7 64.7 64.7 1.3 1.3 1.75 1.75 1.75 1.75 1.3 1.3 4.4 6.3 9.8 11.2 0.69 1.2 2.4 3.5 6.1 9.3 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 20 – 25 – – – – – 50A 63A 80A 100A 100A 125A 50kA 50kA 50kA 50kA 50kA 50kA >=0.85 <=1.1Uc >=0.85 <=1.1Uc >=0.85 <=1.1Uc >=0.85 <=1.1Uc >=0.85 <=1.1Uc >=0.85 <=1.1Uc >=0.2 <=0.75Uc >=0.2 <=0.75Uc >=0.2 <=0.75Uc >=0.2 <=0.75Uc >=0.2 <=0.75Uc >=0.2 <=0.75Uc 92 92 230 230 230 230 8 8 28 28 28 28 2.7 2.7 8.0 8.0 8.0 8.0 12,000 12,000 12,000 12,000 12,000 12,000 B B B B B B 16 16 24 24 24 24 12 12 19 19 19 19 6.4/76.8 3.2/76.8 1.6/76.8 0.64/76.8 6.4/76.8 3.2/76.8 1.6/76.8 0.64/76.8 15.4/126 6.2/88.4 2.9/76.2 1.1/67.3 15.4/126 6.2/88. 2.9/76.2 1.1/67.3 15.4/126 6.2/88.44 2.9/76.2 1.1/67.3 15.4/126 6.2/88.4 2.9/76.2 1.1/67.3 0.28/3.36 0.14/3.36 0.07/3.36 0.028/3.36 0.28/3.36 0.14/3.36 0.07/3.36 0.028/3.36 0.42/4.98 0.21/4.96 0.11/5.04 0.041/4.87 0.42/4.98 0.21/4.96 0.11/5.04 0.041/4.87 0.42/4.98 0.21/4.96 0.11/5.04 0.041/4.87 0.42/4.98 0.21/4.96 0.11/5.04 0.041/4.87 2 2 2* 2* 2* 2* 6 1 6 1 25 (10) 2.5 (2.5) 25 (10) 2.5 (2.5) 25 (10) 2.5 (2.5) 25 (10) 2.5 (2.5) 4 1 4 1 16 (6) 2.5 (2.5) 16 (6) 2.5 (2.5) 16 (6) 2.5 (2.5) 16 (6) 2.5 (2.5) 2 2 2* 2* 2* 2* 10 10 35 (16) 35 (16) 35 (16) 35 (16) * 2 Terminal compartments (upper and lower), the upper having the greater capacity. Lower capacities in brackets. TDO3400001U www.eatonelectrical.com 24 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Contactor CE15LN CE15MN CE15NN Non motor utilisation categories AC-5a Switching of electrical discharge lamps. Ue<=440V, rated current le le le le 100A 135A 150A AC-5b Switching of incandescent loads. Ue<=575V, rated current le 37A 46A 60A AC-6a Switching of transformers. Having inrush current peaks not more than 30 times peak of the rated current. Ue<=575V, rated current le 39A 48A 63A AC-6b Switching of single capacitor banks. Ue kVAr le kVAr le kVAr le Having prospective short circuit current Ik at the location of the capacitor bank. Ue<=575V Ik<=15kA Where Ik is between 15kA and 25kA, derate to 60% of the ratings. Where Ik is between 25kA and 50kA, derate to 30% of the ratings. Average contact resistance per pole (milli-ohms) 220V 380V 415V 440V 500V 550V 575V 26 46 50 53 60 66 23 23 23 23 23 23 23 23 35 61 67 71 81 89 28 28 28 28 28 28 28 28 40 69 75 80 90 100 37 37 37 37 37 37 37 37 0.45 0.45 0.25 Power dissipated at Ith, W 4.5 8.2 5.6 Power dissipated at le max, W 3.3 5 5 Short circuit co-ordination, IEC947-4 Type 2 Type 2 Type 2 Fuse type, BS88 class gG & gM 160A 200A 250A Rated conditional short circuit current (lq) 50kA 50kA 50kA Magnet system Pick up >=0.85 <=1.1 Uc >=0.85 <=1.1 Uc >=0.85 <=1.1 Uc Drop out >=0.2 <=0.75 Uc >=0.2 <=0.75 Uc >=0.2 <=0.75 Uc Pick up VA 390 390 393 Sealed VA 50 50 57 Sealed W 14 14 14 Duty (continuous rated) maximum rate of operation per hour 7,200 7,200 7,200 Insulation class of coil to IEC85 (BS2757) B B B Pick up time (milli-seconds) 20 20 20 11 11 11 24/293 12/288 6.1/295 2.5/298 – 24/293 12/288 6.1/295 2.5/298 – 24/293 12/288 6.1/295 2.5/298 – 0.4/4.84 0.2/4.75 0.097/4.67 0.038/4.57 – 0.4/4.84 0.2/4.75 0.097/4.67 0.038/4.57 – 0.4/4.84 0.2/4.75 0.097/4.67 0.038/4.57 – 2 2 2 3 3 3 Drop out time (milli-seconds) Coil voltage 12V 24V 48V 120V 240V Magnet system – DC operated Pickup VA/W Sealed VA/W 12V 24V 48V 120V 240V Cabling capacity Number of conductors Number of conductors when using terminal extension kit 2 Terminal capacity using compression lugs (mm ) 6 to 35 6 to 35 6 to 35 Terminal bolt/stud size 1 /4 UNC 1 /4 UNC 1 1 1 – 50 70 – 35 50 – Cabling using box lug (supplied) Number of conductors 2 Solid or stranded – Max. size (mm ) 2 Flexible – Max. size (mm ) www.eatonelectrical.com /4 UNC TDO3400001U Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW MCE15PN MCE15RN MCE15SN le le le 185A 220A 315A 73A 86A 129A 77A 90A 135A kV Ar le kV Ar le kV Ar le 49 84 92 98 111 122 45 45 45 45 45 45 45 45 58 101 110 117 133 146 53 53 53 53 53 53 53 53 83 144 158 167 190 209 61 61 61 61 61 61 61 61 0.25 0.25 0.25 8.5 12 25 7.5 10 22 Type 2 Type 2 Type 2 250A 315A 355A 50kA 50kA 50kA >=0.85 <=1.1 Uc >=0.85 <=1.1 Uc >=0.85 <=1.1 Uc >=0.2 <=0.75 uc >=0.2 <=0.75 Uc >=0.2 <=0.75 Uc 1040 1040 1040 116 116 116 17 17 17 2,400 2,400 2,400 B B B 23 23 23 15 15 15 – 18/400 9/400 3.3/450 1.7/440 – 18/400 9/400 3.3/450 1.7/440 – 18/400 9/400 3.3/450 1.7/440 – 0.22/5.3 0.11/5.2 0.05/5.4 0.02/4.9 – 0.22/5.3 0.11/5.2 0.05/5.4 0.02/4.9 – 0.22/5.3 0.11/5.2 0.05/5.4 0.02/4.9 2 2 2 4 4 4 16 to 95 25 to 120 25 to 120 M8 M10 M10 – – – – – – – – – TDO3400001U www.eatonelectrical.com 25 26 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Auxiliary contacts Integral contacts General Standards and approvals Add-on contact blocks Top mounted Side mounted IEC947-5-1, UL508, CSA22.14 Protection against direct contact IP20 to IEC529 IP20 to IEC529 IP20 to IEC529 Mechanical life span 20,000,000 10,000,000 10,000,000 Terminal marking EN50012 (BS5582) EN50012 (BS5582) EN50012 (BS5582) Environment Pollution degree IEC947-1 3 3 3 Impulse withstand voltage IEC947-1 6kV 6kV 6kV Operating temperature, open –20 to +65°C –20 to +65°C –20 to +65°C Operating altitude 2,000m 2,000m 2,000m Weight – 58g 46g Relative humidity Contact ratings Rated thermal current. Open Ith 10A 10A 10A Rated insulation voltage Ui 690V 690V 690V Operating frequency limits 50 to 60Hz 50 to 60Hz 50 to 60Hz Adjacent contacts 'electrically separate' Yes AC15 duty Control of A.C. electromagnetic loads (Greater than 72VA) DC13 duty Control of D.C. electromagnets Short circuit co-ordination Conditional short circuit current Ik Yes Yes Ue VA Ie VA Ie VA Ie 48 120 240 440 660 480 720 960 880 990 10 6 4 2 1.5 480 720 960 880 990 10 6 4 2 1.5 480 720 960 880 990 10 6 4 2 1.5 Ue W Ie W Ie W Ie 24 48 120 220 440 660 19.2 288 120 110 110 66 8 6 1 0.5 0.25 0.1 19.2 288 120 110 110 66 8 6 1 0.5 0.25 0.1 19.2 288 120 110 110 66 8 6 1 0.5 0.25 0.1 1kA 1kA 1kA Fuse type BS88 type gG 10A 10A 10A Average contact resistance per pole (milli-ohms) N.O. 3.5 N.C. 4.5 N.O. 3.5 N.C. 5 N.O. 3.5 N.C. 5 Power dissipated at Ith (W) at Ie 6A (W) 0.35 0.13 0.45 0.16 0.35 0.13 0.5 0.18 0.35 0.126 0.5 0.18 Cabling capacity in accordance with the requirements of IEC947 Number of conductors 2 2 Solid, stranded or flexible – Max. wire size (mm ) – Min. wire size (mm2) Cabling maximum terminal capacity Number of conductors 2 Solid, stranded or flexible – max. wire size (mm ) 2 2 2.5 0.75 2.5 0.75 2.5 0.75 2 2 2 4 4 4 www.eatonelectrical.com TDO3400001U Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Pneumatic timer Base auxiliary contact block Add-on contact blocks IP20 to IEC529 IP20 to IEC529 IP20 to IEC529 20,000,000 5,000,000 5,000,000 EN50012 (BS5582) EN50012 (BS5582) 3 3 3 6kV 6kV 6kV –20 to +65°C –20 to +65°C –20 to +65°C 2,000m 2,000m 2,000m 410g 120g 35g 10A 10A 10A 690V 690V 690V 50-60Hz 50-60Hz 50-60Hz IEC947-5-1, UL508, CSA22.14 Yes No Yes VA Ie VA le VA le – 480 600 880 660 – 4 2.5 2 1 480 720 960 880 990 10 6 4 2 1.5 480 720 960 880 990 10 6 4 2 1.5 W Ie W le W le – – 72 66 66 66 – – 0.6 0.3 0.15 0.1 192 288 120 110 110 66 8 6 1 0.5 0.25 0.1 192 288 120 110 110 66 8 6 1 0.5 0.25 0.1 1kA 1kA 1kA 10A 10A 10A 2 2 2 2.5 0.75 2.5 0.75 2.5 0.75 2 2 2 12 1.2 0.19 4 TDO3400001U www.eatonelectrical.com 27 28 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Technical data Contactors 2.2 to 37kW AC3 electrical durability AC4 electrical durability www.eatonelectrical.com TDO3400001U Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Contactors 45 to 160kW AC3 electrical durability MCE15P MCE15R AC4 electrical durability TDO3400001U www.eatonelectrical.com MCE15S 29 30 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Technical data Overload relays C316FNA3 C316KNA3 C316PNA3 C316SNA3 C316UNA3 General Thermal current Ith Up to 32A Up to 80A Up to 200A Up to 400A CT operated Up to 850A CT operated Standards and approvals IEC 947-4-1, IEC 292-1, BS4941, VDE0660, UL 508, CSA C22-14, NFC 63-650 Trip class IEC947-4-1 10A Terminal marking EN50005 (BS5472) Width (mm) 45 55 80* 193 * Width across terminals is greater, <100A = 85mm, >100A = 105mm Protection against direct contact Protected against unintentional contact in accordance with VDE0106 pt 100 Weight (kg) 0.17 0.32 0.91 1.5 3 3 3 3 3 3 Impulse withstand voltage IEC947-4-1 6kV 6kV 6kV 6kV 6kV Operating temperature, open –25 to +50°C –25 to +55°C –25 to +55°C –25 to +55°C –25 to +55°C Temperature compensation range –25 to +50°C –25 to +50°C –25 to +50°C –25 to +50°C –25 to +50°C Maximum altitude 2000m 2000m 2000m 2000m 2000m Operating position (relative to normal position) ±30° ±30° ±30° ±30° ±30° Climatic conditions Damp heat constant to IEC68-2-3. Damp heat, cyclic to IEC68-2-30 Mechanical shock resistance 12g for 15ms Vibration @ 45Hz 8g (1mm displacement with N.C. contacts maintained) Storage temperature –40 to +70°C Environment Pollution degree IEC947-1 Main contacts Insulation voltage Ui 10A 10A 12g for 15ms –40 to +70°C 12g for 15ms 30 12g for 15ms 30 246 12g for 15ms –40 to +70°C –40 to +70°C –40 to +70°C 690V 690V 690V 690V 690V Current range 0.25 – 32A 18 – 80A 100 – 200A 130 – 400A 265 – 850A Power dissipated at minimum setting at maximum setting 2.2W 3.3W 3.4W 4.9W 5.8W 7.3W 2.2W 3.3W 2.2W 3.3W 50kA 50kA 50kA Max operating frequency of motor (starts per hour) 15 (dependent upon starting time and current) Short circuit co-ordination Type 2 to IEC947-4-1 Rated conditional short circuit current 50kA Fuse type See table on page 19 50kA Cabling capacity in accordance with the requirements of IEC947-1 Number of conductors 1 2 1 2 – – – Solid or stranded - Max. wire size (mm˝) - Min. wire size (mm˝) 10 1.5 6 1.5 35 2.5 15 2.5 – – – – – – Flexible - Max. wire size (mm˝) - Min. wire size (mm˝) 6 1.5 4 1.5 25 2.5 10 2.5 – – – – – – Cabling capacity using compression lugs (mm˝) – – 25 to 120 – – Terminal flag bolt size - <100A - >100A – – – – M6 M10 – – – – CT aperture size (mm) – – – 22 x 28 45 x 22 www.eatonelectrical.com TDO3400001U Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Technical data Auxiliary contacts N.C. (95 – 96) General Protection against direct contact Mechanical life span Contact ratings Thermal current Ith N.O. (97 – 98) IP20 to IEC529 IP20 to IEC529 50,000 50,000 10A 6A Insulation voltage Ui 500V 500V Operating frequency limits 50/60Hz 50/60Hz Adjacent contacts 'electrically separate' Yes Yes AC15 duty Control of A.C. electromagnetic loads (Greater than 72VA) DC13 duty Control of D.C. electromagnets Short circuit co-ordination Conditional short circuit current Iq Fuse type BS88 type gG Ue 120 240 415 500 VA 360 720 830 750 Ie 3 3 2 1.5 VA 204 408 539 500 Ie 1.7 1.7 1.3 1 Ue 220 W 110 Ie 0.5 W 110 Ie 0.5 1kA 1kA 10A 6A Cabling capacity in accordance with the requirements of IEC947-1 Number of conductors 2 2 Solid or stranded - Max. wire size (mm˝) - Min. wire size (mm˝) 4 0.75 4 0.75 Flexible - Max. wire size (mm˝) - Min. wire size (mm˝) 2.5 0.75 2.5 0.75 Standard features Remote reset module Circuit diagram L1 Test trip lever Identification label mounting Trip Pushbutton (convertible) Reset mode selector Man Aut 97 96 Cut-out contact Trip indicator 95 Control terminals Outgoings. Main terminals 2/T1 TDO3400001U 4/T2 N L2 Command contact Calibration selector 98 Impulse duration 0.2 to 0.3 secs. 6/T3 www.eatonelectrical.com 97 O/L 98 Remote reset coil E1 E2 Overload relay must be set in the manual reset mode 31 32 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Technical data Overload time/current characteristics C316FNA3 thermal overload relay FLC current ranges 0.25 to 32A C316KNA3 thermal overload relay FLC current ranges 18 to 80A C316PNA3 thermal overload relay FLC current ranges 100 to 200A C316SNA3 thermal overload relay FLC current ranges 130 to 400A www.eatonelectrical.com TDO3400001U Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Dimensions (mm) Contactors CE15AN to FN Mechanically interlocked contactors CE15AN to FN contactor + C316FNA3 thermal C316FNA3 thermal overload relay and C306TB1 overload relay mounting adaptor C316FNA3 thermal overload relay + C316RR1 remote reset module TDO3400001U www.eatonelectrical.com 33 34 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Dimensions mm (continued) Contactors CE15GN to KN CE15GN to KN contactor + C316KNA3 thermal overload relay Contactors CE15LN to NN Mechanically interlocked contactors C316KNA3 thermal overload relay and C316TB1 overload relay mounting adaptor Mechanically interlocked contactors www.eatonelectrical.com TDO3400001U Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Contactors MCE15PN to SN Mechanically interlocked contactors MCE15PN 236 MCE15RN to SN 265 C316PNA3 thermal overload relay CE15LN to NN contactor + CE16PNA3 thermal overload relay (with links C316MCL) TDO3400001U MCE15PN to SN contactor + C316PNA3 thermal overload relay (with links C316PCL) www.eatonelectrical.com 35 36 Freedom Series Contactors and Overload Relays April 2005 Freedom Series – 2.2 to 160kW Dimensions mm (continued) C316SNA3 CT operated thermal overload relay Contactor safety perimeter zones (mm) Contactors CE15AN to FN Contactors CE15LN to NN X Contactors CE15GN to KN X Y Ue ≤460V 1.5 14 Ue >460V 12 29 Ue ≤460V 30 Ue >460V 55 Contactors MCE15PN to SN www.eatonelectrical.com TDO3400001U Freedom Series Contactors and Overload Relays 37 April 2005 Freedom Series – 2.2 to 160kW Three phase 50Hz motors approx. FLC at line voltage This table is based on motors of approximately 1450 r.p.m. of average efficiency and power factor. Motors of higher speed than 1450 r.p.m. usually take a lower current than that shown in the table; while motors of lower speed usually take higher current. Wide variations from these figures can arise and engineers should, whenever possible, determine the actual FLC from the motor rating plate in each case. Motor rating kW hp Voltage 220 380 415 500 550 660 Motor rating kW hp Voltage 220 380 415 500 550 660 0.37 0.55 0.75 0.5 0.75 1.0 2.1 2.8 3.5 1.2 1.6 2.0 1.1 1.5 1.9 0.9 1.2 1.5 0.8 1.1 1.4 0.7 0.9 1.2 30 37 45 40 50 60 100 125 150 59 73 86 54 67 79 45 55 66 41 50 60 34 42 50 1.1 1.5 2.2 1.5 2.0 3.0 4.9 6.3 9.0 2.9 3.6 5.2 2.6 3.3 4.8 2.2 2.8 4.0 2.0 2.5 3.6 1.6 2.1 3.0 55 75 90 75 100 125 180 240 300 106 140 170 98 130 160 81 105 130 74 96 120 61 80 99 3.0 4.0 5.5 4.0 5.5 7.5 12 16 21 6.8 9.1 12 6.2 8.3 11 5.1 6.9 9.4 4.7 6.3 8.5 3.9 5.2 7.1 110 132 160 150 175 220 350 410 510 200 240 300 190 220 270 160 180 230 140 160 210 120 140 170 7.5 10 11 10 13.5 15 27 36 40 16 21 23 14 19 21 12 16 17 11 14 16 9.1 12 13 200 220 250 270 300 350 630 730 810 360 420 470 330 380 430 280 320 360 250 290 320 210 240 270 15 18.5 22 20 25 30 52 64 77 30 37 44 28 34 41 23 28 34 21 26 31 17 21 26 It is important to note that these figures are average values and that actual values can vary by +20% –10% for motors up to 7.5kW and by ±10% for motors above 7.5kW. Star-delta starters utilising smaller star contactor size Ue = 380/415V Star delta starters Starter (kW) Main/Delta contactor Starter Ie line current (A) Star contactor size Without mech interlock With mech interlock 5.5 7.5 11 15 18.5 22 CE15A CE15B CE15C CE15D CE15E CE15F 12 16 23 30 37 44 CE15A CE15A CE15B CE15C CE15D CE15D CE15A CE15A CE15B CE15C CE15D CE15D 30 37 45 55 75 90 CE15G CE15H CE15J CE15K CE15L CE15M 59 73 86 100 140 170 CE15E CE15F CE15G CE15G CE15H CE15K CE15G CE15G CE15G CE15G CE15L CE15L 110 132 160 200 250 CE15N CE15N MCE15R MCE15R MCE15S 190 240 300 360 470 CE15L CE15M CE15N CE15N MCE15P CE15N CE15N CE15N CE15N MCE15P Notes: 1. Main and delta contactors delta connected. 2. Star contactor life 100,00 operations or greater at normal starting duty (make 2 x Ie, break 1 x Ie). TDO3400001U 3. Maximum starting time in the star connection 25 seconds. 4. For heavy duty starting where the star contactor breaks >1 x Ie, or where the starting time in the star connection is greater than 25 seconds, or where contactor life is insufficient, use the same size of contactor as for main and delta. www.eatonelectrical.com 38 Modular Series Contactors April 2005 Catalogue numbers Contactors AC1 rating (A) Number of poles N.O. N.C. Width (mm) Catalogue number 30 30 30 40 4 2 – 4 – 2 4 – 45 45 45 45 GH15BN40* GH15BN22* GH15BN04* GH15DN40* 50 63 63 63 4 4 2 – – – 2 4 60 60 60 60 GH15FN40* GH15GN40* GH15GN22* GH15GN04* 80 100 4 4 – – 70 70 GH15HN40* GH15JN40* 125 125 125 4 2 – – 2 4 105 105 105 GH15LN40* GH15LN22* GH15LN04* 160 3 – 150 GH33B-3-22* 200 3 – 150 GH35B-3-22* 250 3 – 150 GH37B-3-22* * Add suffix from the table to select coil operating voltage. For voltages not shown please contact Head Office. www.eatonelectrical.com TDO3400001U Modular Series Contactors 39 April 2005 Contactors AC1 rating (A) Number of poles* N.O. N.C. Width (mm) Catalogue number 350 3 – 177 GH44-3-22* 450 3 – 214 GH52-3-22* 240 3 – 220 GH55-3-22* 280 3 – 220 GH57-3-22* 375 3 – 280 GH62-3-22* 475 3 – 280 GH64-3-22* 550 3 – 334 GH76-3-12* 650 3 – 334 GH78-3-12* * Select add-on neutral switching pole, see page 41 TDO3400001U www.eatonelectrical.com 40 Modular Series Contactors April 2005 Operating coils Contactors GH15 to GH55 Combined dual frequency AC and DC coils Contactors GH76 to 78 Dual frequency AC coils Coil voltage 50/60Hz D.C. Suffix code Coil voltage 50/60Hz Suffix code 110/120 220/240 380/415 440/480 110 200/220 345/380 400/440 A K M C 110/120 220/240 380/415 440/480 A K M C DC coils 48 120 220 W1 A1 B1 Accessories Standard available control voltages Contactor type GH15BN GH15DN GH15FN GH15HN GH15HN GH15LN GH33B GH35B GH37B GH44 GH52 GH55 GH57 GH62 GH64 GH76 GH78 Coil type B01– B02– B021– B31– B9– B7– B51– B61– B8– / / / / / / FG51 FG61 FG78 50-60 50-60 50-60 Feeder group type AC voltage DC voltage Hz 50-60 50 V V V V V V V V V V V 24 48 110-120 24 48 110 V V V V 60 50-60(1) 50-60 50 60 24 48 110 24 48 110-120 24 48 110 220 220-240 220-230 240 380-415 380-400 415 115 220-240 380-415 22-230 240 380-400 415 240 440-480 440 460 480 24 48 110 220 24 48 110 220 110 115 220 240 50 60 24 48 110 220-230 240 380-400 415 440 460 480 24 48 110 220 24 48 110 220 110 115 220 240 50 60 24 48 110 220-230 240 380-400 415 440 460 480 24 48 110 220 110 115 220 240 440 460 480 24 48 110 220 24 24 48 48 110-120 110-120 110-115 220-240 220-240 220-230 240 380-415 380-415 380-400 440 440-480 440-480 24 24 48 48 100-110 100-110 200-220 200-220 110 220 EG B01–240 is a 240V coil for a GH15DN contactor With these coils at 50Hz the comsumption is increaded by 25% and the mechanical durability is reduced by 50% www.eatonelectrical.com TDO3400001U Modular Series Contactors 41 April 2005 Accessories Table Description GH15BN, GH15DN, GH15FN, GH15HN, GH15JN, GH15LN Add on Aux control blocks 1no GH15T01 1nc GH15T10 1no-1nc GH15T11 1no-1nc Add on* 2no-2nc GH15T22 3no-1nc GH15T31 4no GH15T40 GH33B, GH35B, GH37B GH44 GH52 GH55 GH57 GH62 & 64 GH76 & 78 GH15T11-3 GH15T11-3A - EF22 - EF22 - EF22 - EF22 - EF22 - EB11 - NP125-3 NP250-3 - NP175-4 NP350-3 - NP325-5 NP500-3 - NP325-5 NP500-5 NP760-5 - NP325-5 NP500-5 NP760-5 - NP500-6 NP1000-6 NP1000-7 Add on neautral Switching Pole 125 (lth) 175 (lth) 250 (lth) 325 (lth) 350 (lth) 500 (lth) 760 (lth) 1000 (lth) Mechnical interlock Horizontal Vertical BMOH - BM07 - BM08 BM09 BM5H BM5V BM5H BM5V BM5H BM5V BM6H BM6V BM6H BM7V Mechanical Latch Kit Kit complete - - AM44 AM5-52 AM5 AM5 AM6 - Three pole shrouds shrouds - PR37 PR44 PR55 PR55 PR57 PR62 PR64 Catalogue numbers – Accessories Auxiliary contact blocks - top mounting (max 1 per contactor) Pneumatic timer - top mounting Contact configuration Catalogue numbers Description 1 N.O. – 1 N.O. 2 N.O. – 2 N.O. 3 N.O. 4 N.O. C320KGT1 C320KGT2 C320KGT3 C320KGT4 C320KGT5 C320KGT15 C320KGT14 C320KGT13 Adjustable range (On or off delay) 0.3 to 30 secs. 10 to 180 secs. – 1 N.C. 1 N.C. – 2 N.C. 2 N.C. 1 N.C. – Suffix code TDO3400001U 50Hz 60Hz C320TP1 C320TP2 Note: When timer is used, other top mounting auxiliaries cannot be added. A.C. Operating coil Coil voltage Catalogue numbers 24 – 48 – 110 120 220 240 240 – 380 – 415 – 440 480 550 600 U Y A B K L M C D www.eatonelectrical.com 42 Modular Series Contactors April 2005 Technical data Contactor GH15BN GH15DN GH15FN GH15HN GH15JN General kW AC3 rating 400V 4 7.5 15 22 30 Standards and approvals IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1 Width mm 45 45 60 79 Number of poles (maximum) 4 4 4 4 4 Add on 4th pole N/A N/A N/A N/A N/A Protection against direct contact IP20-IP10* IP20-IP10* IP20-IP10* IP20-IP10* IP20-IP10* Mechanical lifespan 1,000,000 1,000,000 1,000,000 1,000,000 1,000,000 Weight kg 0.4 0.4 0.9 1.28 1.28 Environment Pollution degree 3 3 3 3 3 Operating temperature –25 to +55°C –25 to +55°C –25 to +55°C –25 to +55°C –25 to +55°C Relative humidity at 40°C 92% 92% 92% 92% 92% Operating altitude 2000m 2000m 2000m 2000m 2000m Operating position (relative to normal mounting position) 90° 90° 90° 90° 90° 690V Main contact ratings Insulating voltage 690V 690V 690V 690V Operating frequency limits Per Hour 3000 3000 3000 3000 3000 Rated thermal current Ith 30 40 50 80 100 230V 12 15 20 31 39 240V 12 16 20 33 41 400V 20 27 34 55 69 415V 21 28 235 57 71 440V 22 30 38 60 76 500V 25 34 43 69 86 690V 35 47 59 95 119 2.2 4 7.5 12.5 18.5 AC1 Watts AC2/3 Watts 230V 240V 2.2 4 7.5 15 18.5 400V 4 7.5 15 22 30 415V 4.3 8 15 22 30 440V 4.7 9 16.5 25 33 500V 5.5 10 15 22 30 690V 5.5 7.5 15 22 30 440V 9 16 32 50 63 500V 9 16 24 38 45 690V 7 9 18 26 34 AC2/3 IE AC4 Watts 230V 0.9 1.6 3 5.5 7.5 240V 1.5 3 5.5 11 15 400V 1.5 3 5.5 11 15 415V 1.5 3 5.5 11 15 440V 1.5 3 5.5 11 15 500V 1.5 3 5.5 11 15 4 7 12 23 30 AC4 IE 440V www.eatonelectrical.com TDO3400001U Modular Series Contactors 43 April 2005 Technical data Contactor GH15LN GH33B GH35B GH37B GH44 GH52 General kW AC3 rating 400V 160 45 55 75 90 110 Standards and approvals IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1 Width mm 105 168 168 168 223 223 Number of poles (maximum) 4 3* 3* 3* 3* 3* Add on 4th pole N/A NP125-3/NP250-3 NP125-3/NP250-3 NP125-3/NP250-3 NP175-4/NP350-4 NP325-5/NP500-5 Protection against direct contact IP20-IP10* IP00 IP00 IP00 IP00 IP00 Mechanical lifespan 1,000,000 1,000,000 1,000,000 1,000,000 800,000 500,000 Weight kg 2.2 5 5 5 7.3 12.8 Environment Pollution degree 3 3 3 3 3 3 Operating temperature –25 to +55°C –25 to +55°C –25 to +55°C –25 to +55°C –25 to +55°C –25 to +55°C Relative humidity at 40°C 92% 92% 92% 92% 92% 92% Operating altitude 2000m 2000m 2000m 2000m 2000m 2000m Operating position (relative to normal mounting position) 90° 90° 90° 25° 25° 25° 690V Main contact ratings Insulating voltage 690V 690V 690V 690V 690V Operating frequency limits Per Hour 3000 3000 3000 3000 3000 3000 Rated thermal current Ith 125 160 200 250 350 400 49 63 79 99 139 179 AC1 Watts 230V 240V 51 66 83 103 145 187 400V 86 110 138 173 242 311 415V 89 115 143 179 251 323 440V 95 121 152 190 266 342 500V 108 138 173 216 303 389 690V 149 191 239 298 418 537 230V 25 33 40 50 60 90 240V 25 33 45 55 65 100 400V 45 55 75 90 110 160 415V 47 59 80 95 115 180 440V 51 63 85 100 125 190 500V 51 55 75 100 132 210 690V 51 55 75 110 132 210 440V 95 115 150 175 210 315 500V 80 85 110 145 210 315 690V 60 70 85 120 150 240 AC2/3 Watts AC2/3 IE AC4 Watts 230V 11 12 15 18.5 25 37 240V 18.5 22 25 30 45 63 400V 18.5 22 25 33 45 65 415V 22 25 30 34 48 67 440V 22 22 25 30 55 75 500V 22 22 25 30 55 75 40 45 55 63 AC4 IE 440V TDO3400001U www.eatonelectrical.com 120 44 Modular Series Contactors April 2005 Technical data (continued) Electrical and Mechanical Ratings for Contactors to IEC 60947-1 Operating conditions: Cooling air temperature surrounding contactor = –20°C to +55°C Maximum altitude = 2000m. A.C. ratings are 3 phase 50–60Hz for main contacts. Contactor GH55 GH57 GH62 Insulation voltage Ui 1000 1000 1000 Thermal current (Ith open) 600 760 1000 kW kW kW AC1 (2) Non-inductive or slightly inductive loads P.F. = 0.95 Ratings are for open contactors at ambient temperatures ≤ 55°C 220/240V 380V 415/440V 500/550V 660V 1000V 185 315 365 420 550 835 230 400 465 530 730 1060 306 527 612 697 918 1360 kW leA kW leA kW IeA AC2 Slipring motors starting and plugging AC3 Squirrel cage motors starting and F.L.C. breaking 220/240V 380V 415/440V 500/550V 660V 1000V 129 220 240 300 335 280 450 450 450 420 350 170 160 280 315 375 450 355 550 550 550 520 450 260 220 375 400 500 600 500 700 700 700 630 630 350 AC4 Squirrel cage motor starting, inching, plugging. Stopping during run up 220/240V 380V 415/440V 500/550V 660V 45 75 80 100 100 180 180 180 140 140 51 90 100 110 110 200 200 200 145 145 68 120 132 150 150 220 220 220 150 150 Maximum number of operations per hour at above ratings AC2/AC3 – AC4 duty 300 – 100 300 – 100 300 – 100 Other ratings kW IL kW IL kW IL 220V 380V 415/440V 500/550V 660V 220 335 400 400 450 700 700 700 650 550 270 450 500 500 600 900 900 900 800 650 300 600 650 700 800 1100 1100 1100 900 850 General data Star delta starter (Delta loop connected) Rotor contactors (Delta connected) Intermediate (1) Final A A 1000 700 1300 900 1600 1100 Transformer primary switching 440V A 180 220 300 Tungsten or infra-red lamps 250V A 260 315 440 Mercury vapour lamps 440V A 400 500 650 Non-compensated fluorescent lamps 440V A Compensated fluorescent and sodium vapour lamps 440V A 360 300 450 360 570 460 Capacitor switching (Single bank only) 380V 3ph kVAr 200 250 350 Average operating times (AC coil) Pick up Drop out ms ms 100 170 100 170 105 200 AC coil consumption Pick up – Seal Seal VA Watts 950 – 11 10 950 - 11 10 1600 - 25 22 Mechanical endurance Millions of operations 5 5 5 (1) Ratings apply when intermediate contactors are shorted out by final contactor and have an on-load time ≤ 15 secs. (2) When contactors are operated continuously at maximum AC1 ratings excessive terminal temperature rises can occur due to oxidation of terminals and/or contamination of contacts. It is recommended that plated or oxidation protected external connections are used. Note: leA figures given are contactor maximum amperes. www.eatonelectrical.com TDO3400001U Modular Series Contactors April 2005 GH64 GH76 GH78 1000 660 660 1100 1200 1350 kW kW kW 335 580 670 765 1000 1525 365 635 735 835 1100 – 415 715 830 945 1245 – kW leA kW leA kW leA 270 475 500 600 650 550 860 860 860 760 680 380 320 550 600 720 930 – 1000 1000 1000 1000 1000 – 380 650 700 840 1120 – 1200 1200 1200 1200 1200 – 80 150 160 180 180 240 240 240 160 160 110 185 200 240 240 370 370 370 300 250 132 220 230 250 275 400 400 400 350 285 300 – 100 120 – 30 120 – 30 kW IL kW IL kW IL 400 700 750 850 900 1300 1300 1300 1000 1000 450 850 900 1000 1200 1500 1500 1500 1100 1100 – 950 – 1100 1400 – – – – – 2000 1300 2500 1500 3000 1700 350 400 500 500 560 630 800 950 1100 700 500 850 660 1000 800 400 450 500 105 200 70 50 70 50 1600 – 25 22 2450 – 75 60 2450 – 75 60 5 1 1 TDO3400001U www.eatonelectrical.com 45 Modular Series Contactors 46 April 2005 Technical data (continued) Auxiliary GH15T01 GH15T10 GH15T11 GH15T22 GH15T31 GH15T40 C320TP1 TypeTop mount Aux Top mount Aux Top mount Aux Top mount Aux Top mount Aux Top mount Aux Top mount Aux Top mount Aux Contacts 1 N/C 1 N/O 1 N/O – 1 N/C 2 N/O – 2 N/C 3 N/O – 1 N/C 4 N/O 1 N/O – 1 N/C Time delay - - - - - - 0.3 – 30SEC Weight kg 0.011 0.011 0.05 0.05 0.05 0.05 0.08 Ui 690 690 690 690 690 690 690 ith A 10 10 10 10 10 10 10 Short time withstand 500ms 60A 500ms 60A 500ms 60A 500ms 60A 500ms 60A 500ms 60A 500ms 60A Protection fuse 10 A gG 10 A gG 10 A gG 10 A gG 10 A gG 10 A gG 10 A gG 120V 6 6 6 6 6 6 4 240V 3 3 3 3 3 3 2.5 400V 2 2 2 2 2 2 2 500V 1.5 1.5 1.5 1.5 1.5 1.5 1.5 690V 1 1 1 1 1 1 1 24V 5 5 5 5 5 5 - 48V 2 2 2 2 2 2 - 110V 0.8 0.8 0.8 0.8 0.8 0.8 0.6 220V 0.4 0.4 0.4 0.4 0.4 0.4 0.3 Auxiliary C320TP2 GH15S11 GH15S11-3 GH15S11-3A* EF22 EB11 TypeTop mount Aux Side mount Aux Side mount Aux Side mount Aux Side mount Aux Side mount Aux AC15 DC13 Contacts 1 N/O – 1 N/C 1 N/O – 1 N/C 1 N/O – 1 N/C 1 N/O – 1 N/C 2 N/O – 2 N/C 1 N/O – 1 N/C Time delay 10-180 SEC - - - - - Weight kg 0.08 0.05 0.08 0.08 0.12 0.17 Ui 690 690 690 690 690 690 ith A 10 10 10 10 16 16 Short time withstand 500ms 60A 500ms 60A 500ms 60A 500ms 60A 500ms 60A 500ms 60A Protection fuse 10 A gG 10 A gG 10 A gG 10 A gG 10 A gG 10 A gG AC15 120V 4 6 6 6 6 6 240V 2.5 3 3 3 3 3 400V 2 2 2 2 2 2 500V 1.5 1.5 1.5 1.5 1.5 1.5 690V 1 1 1 1 1 1 24V - 4 4 4 6 6 48V 1 1.5 1.5 1.5 3 3 110V 0.6 0.5 0.5 0.5 1 1 220V 0.3 0.2 0.2 0.2 0.5 0.5 DC13 www.eatonelectrical.com TDO3400001U Modular Series Contactors 47 April 2005 Dimensions (mm) Sizes GH15BN & DN Sizes GH15GN, HN & JN Four-pole contactors - AC coil GH15FN GH15GN GH15HN GH15JN GH15LN TDO3400001U www.eatonelectrical.com 48 Modular Series Contactors April 2005 Three-pole contactors - AC coil DC coil Three/Four-pole Contactors - AC coil Contactor GH55 GH57 GH62 GH64 GH76 GH78 Dimension A B C D E F G H J K L Mechanical intlk. mounting matrix Horiz Vert Weight (kg) 220 220 280 280 334 334 225 225 291 291 345 345 110 110 175 175 120 120 220 220 280 280 380 380 160 160 200 200 220 220 72 72 90 90 111 111 8 8 10 10 12 12 30 40 50 50 50 60 10.5 12.5 13 15 17 x 2 17 x 2 80 80 100 100 100 100 262 262 312 312 380 380 13 13.5 26 28 49 53 233 258 307 361 490 490 www.eatonelectrical.com 314 314 380 380 580 580 TDO3400001U Modular Series Overload Relays April 2005 Overload Relays Catalogue numbers For direct connection with CE15AN to FN contactors or independent mounting Description Motor FLC range A Catalogue numbers Relay with 1 N.O. – 1 N.C. electrically separate contacts, selectable hand or auto reset with reset or stop-reset option, phase loss protection and trip indicator. 0.25 0.4 0.63 1.0 1.3 1.7 2.2 2.8 3.5 4.5 6.0 7.5 10 13 18 24 C316FNA3C C316FNA3D C316FNA3E C316FNA3F C316FNA3G C316FNA3H C316FNA3J C316FNA3K C316FNA3L C316FNA3M C316FNA3N C316FNA3P C316FNA3Q C316FNA3R C316FNA3S C316FNA3T – – – – – – – – – – – – – – – – 0.4 0.63 1.0 1.4 1.8 2.4 3.1 4.0 5.0 6.5 8.5 11.0 14.0 19.0 24.0 32.0 Separate base for independent connection and DIN rail or panel mounting C306TB1 Thermal overload relays for independent mounting and connection with GH33 & GH37 contactors.➀ 65 80 100 110 130 150 – – – – – – 90 110 135 150 175 200 C316PNA3A C316PNA3B C316PNA3C C316PNA3D C316PNA3E C316PNA3F Thermal overload relays, current transformer operated, for independent connection with GH44 contactors.➀ 130 165 220 285 – – – – 185 235 310 400 Identification marker (pack of 50) C316SNA3A C316SNA3B C316SNA3C C316SNA3D C316MT1 Thermal overload relays, current transformer operated, for independent connection to GH55 to 78 contactors.➀ 355 – 465 – 610 – 500 650 850 C316UNA3A C316UNA3B C316UNA3C Remote reset module Description Operating voltage 50/60HZ Catalogue number For use with thermal overload relays C316SNA3 and C316UNA3 220/440 C316RR1N ➀ Relay with 1N.O. – 1N.C. electrically separate contacts, selectable hand or auto reset with reset or stop-reset option, phase loss protection and trip indicator. TDO3400001U www.eatonelectrical.com 49 50 Modular Series Overload Relays April 2005 Overload Relays Technical data Electrical life The two graphs below show average contact life for AC3 and AC4 duties respectively. To obtain the contact life for duties which include a proportion of both AC3 and AC4 operations the following may be used. Contact life = where N.P Z.N. + S.P N = AC3 life Z = % AC4 operations P = AC4 life S = % AC3 operations Select AC3 and AC4 life for operational current required from graphs below. Estimate number of AC4 operations in percent and calculate from above equation. Auxiliary contacts Terminal markings Specifications IEC337-1, BS4774-1 Maximum number 4 N.O. - 4 N.C. Thermal rating 25A Contact ratings AC11 Rated operational voltage UeV Rated operational current IeA 120 240 440 600 14 7 4 2 Contact rating DC11 Rated operational voltage dc Rated operational current IeA 24 48 110 220 18 15 7 4 Terminal capacity Solid or stranded: 2 x 4mm˝ www.eatonelectrical.com TDO3400001U Modular Series Overload Relays 51 April 2005 Overload Relays Technical data Overload relays General Thermal current Ith Standards and approvals C316PNA3 C316SNA3 C316UNA3 Up to 200A CT operated Up to 400A CT operated Up to 850A IEC 947-4-1, IEC 292-1, BS4941, VDE0660, UL 508, CSA C22-14, NFC 63-650 Trip class IEC947-4-1 10A Terminal marking EN50005 (BS5472) Width (mm) 80* 193 246 * Width across terminals is greater, <100A = 85mm, >100A = 105mm Protection against direct contact Protected against unintentional contact in accordance with VDE0106 pt 100 Weight (kg) 0.91 1.5 3 Environment Pollution degree IEC947-1 30 30 3 3 3 Impulse withstand voltage IEC947-4-1 6kV 6kV 6kV Operating temperature, open –25 to +55°C –25 to +55°C –25 to +55°C Temperature compensation range –25 to +50°C –25 to +50°C –25 to +50°C Maximum altitude 2000m 2000m 2000m Operating position (relative to normal position) ±30° ±30° ±30° Climatic conditions Damp heat constant to IEC68-2-3. Damp heat, cyclic to IEC68-2-30 Mechanical shock resistance 12g for 15ms Vibration @ 45Hz 8g (1mm displacement with N.C. contacts maintained) Storage temperature –40 to +70°C –40 to +70°C –40 to +70°C 690V 690V 690V Current range 100 – 200A 130 – 400A 265 – 850A Power dissipatedat minimum setting at maximum setting 5.8W 7.3W 2.2W 3.3W 2.2W 3.3W Max operating frequency of motor (starts per hour) 15 (dependent upon starting time and current) Short circuit co-ordination Type 2 to IEC947-4-1 Main contacts Insulation voltage Ui Rated conditional short circuit current 50kA Fuse type See table on page 46 Cabling capacity in accordance with the requirements of IEC947-1 Cabling capacity using compression lugs (mm˝) 25 to 120 12g for 15ms 12g for 15ms 50kA 50kA – – Terminal flag bolt size - <100A - >100A M6 M10 – – – – CT aperture size (mm) – 22 x 28 45 x 22 TDO3400001U www.eatonelectrical.com 52 Modular Series Overload Relays April 2005 Overload Relays Technical data (continued) General Protection against direct contact Mechanical life span Contact ratings Thermal current Ith Auxiliary contacts N.C. (95 – 96) N.O. (97 – 98) IP20 to IEC529 IP20 to IEC529 50,000 50,000 10A 6A Insulation voltage Ui 500V 500V Operating frequency limits 50/60Hz 50/60Hz Adjacent contacts 'electrically separate' Yes Yes AC15 duty Control of A.C. electromagnetic loads (Greater than 72VA) DC13 duty Control of D.C. electromagnets Ue 120 240 415 500 VA 360 720 830 750 Ie 3 3 2 1.5 VA 204 408 539 500 Ie 1.7 1.7 1.3 1 Ue 220 W 110 Ie 0.5 W 110 Ie 0.5 Short circuit coordination Conditional short circuit current Iq 1kA 1kA Fuse type BS88 type gG 10A 6A Circuit breaker type To be announced To be announced Cabling capacity in accordance with the requirements of IEC947-1 Number of conductors 2 Remote reset module 2 Solid or stranded - Max. wire size (mm˝) - Min. wire size (mm˝) 4 0.75 4 0.75 Flexible - Max. wire size (mm˝) - Min. wire size (mm˝) 2.5 0.75 2.5 0.75 Standard features 3 pole adjustable overload relay or current transformer operated relay for heavy starting duty. Auto Automatic reset after tripping. Normally associated with three-wire controls. Test trip lever Auxiliary contacts make & break (separate). For fitting directly on to contactor, or for separate mounting. Temperature compensated. Identification label mounting Trip Pushbutton (convertible) Reset mode selector Clearly marked setting scale Facilitates accurate setting, even for intermediate values. Setting lever for hand or auto reset Supplied set to "Man" (with hand reset) Manual After tripping, reset button must be operated. Normally associated with two-wire controls for safety reasons and to prevent "pumping". Man Aut Trip indicator Calibration selector 98 97 96 95 Control terminals Outgoings. Main terminals 2/T1 4/T2 6/T3 www.eatonelectrical.com Reset button (internal reset) To reset after tripping when reset is set to "Man". If fault still exists, trips free even if reset button is held down. Test lever To simulate tripping of overload relay. Off button To de-energise self maintaining contactors. Current transformer operated overload relay The specified primary rated current applies to one cable loop (C316UNA3*). For lower rated motor currents loop cable several times. TDO3400001U Modular Series Overload Relays 53 April 2005 Overload Relays Technical data (continued) Recommended fuse sizes for type 2 co-ordination Catalogue Motor full load current number range (A) BS88 gG/gM (A) DIN type gL/gi (A) DIN type aM (A) C316PNA3A C316PNA3B C316PNA3C C316PNA3D C316PNA3E C316PNA3F 65 80 100 110 130 150 – – – – – – 90 100 135 150 175 200 200 200 200 250 315 315 200 224 224 250 315 315 160 200 200 224 250 250 C316SNA3A C316SNA3B C316SNA3C C316SNA3D 130 165 220 285 – – – – 185 235 310 400 355 450 630 750 355 400 500 630 – – – – C316UNA3A C316UNA3B C316UNA3C C316UNA3D 265 355 465 610 – – – – 375 500 650 850 500 750 1000 1250 800 1000 1250 1250 – – – – Overload time/ Current characteristics C316PNA3 thermal overload relay FLC current ranges 100 to 200A C316SNA3 thermal overload relay FLC current ranges 130 to 400A 1.126 1.2 1.06 1.126 1.2 1.06 10000 10000 5000 5000 Trip time (secs) Trip time (secs) Cold Top line: 3 phase Bottom line: 2 phase Hot 500 120 Cold Top line: 3 phase Bottom line: 2 phase 1000 1000 Hot Top line: 3 phase Bottom line: 2 phase 500 120 100 100 50 50 10 10 5 5 2 1 0.7 1 0.8 2 1 0.7 1 0.8 1.5 2 3 4 5 6 8 10 7.2 Multiples of full load current C316UNA3 thermal overload relay FLC current ranges 265 to 850A 20 1.126 1.2 1.06 10000 5000 Trip time (secs) Cold Top line: 3 phase Bottom line: 2 phase 1000 Hot 500 120 Top line: 3 phase Bottom line: 2 phase 100 50 10 5 2 1 0.7 1 0.8 TDO3400001U 1.5 2 3 4 5 6 8 10 7.2 Multiples of full load current Top line: 3 phase Bottom line: 2 phase 20 www.eatonelectrical.com 1.5 2 3 4 5 6 8 10 7.2 Multiples of full load current 20 Modular Series Overload Relays 54 April 2005 Overload Relays Technical data (continued) C316UNA3 thermal overload relays Approvals and standards IEC947-4 class 10A relay with single phase detection IEC337, BS4941, VDE0660, CSA, UL Electrical ratings Insulation voltage Ui: 660 Volts AC Climatic conditions Maximum altitude: 2000 metres Ambient temperature compensation range: –25°C to +55°C Storage temperature range: –40°C to +70°C Relative humidity: 95% RH at 40°C DIN50017 Control contact ratings 1N.O. – 1N.C. electrically separate Rating N.C. 95-96 N.O. 97-98 Thermal current Ith Rated operational current Ie at AC15 220V 380V 500V Maximum fuse size 10A 6A 3A 2A 1.5A 10A 1.7A 1.3A 1A 6A Co-ordination with short circuit protection devices Catalogue number Ratings of fuses for type 2 coordination BS88 class Q1 VDE0660 gl C316UNA3A C316UNA3B C316UNA3C C316UNA3A 450A 630A 710A 1000A Typical trip characteristics Reset function Selectable: Automatic, manual or manual/stop Reset time <5 minutes Terminal capacities Terminals nos. 95 to 98: 2 x 2.5 or 2 x 4 Terminal markings 500A 800A 1000A 1250A Dimensions (mm) Thermal overload relay 4.5 Reset 45 203 22 44 83 83 245 www.eatonelectrical.com TDO3400001U Eaton’s Electrical business is a global leader in electrical control, power distribution, and industrial automation products and services. Through advanced product development, world-class manufacturing methods, and global engineering services and support, Eaton’s Electrical business provides customer-driven solutions under brand names such as Cutler-Hammer® , Durant® , Heinemann® , Holec® and MEM® , which globally serve the changing needs of the industrial, utility, light commercial, residential, and OEM markets. For more information, visit www.EatonElectrical.com. Eaton Corporation is a diversified industrial manufacturer with 2004 sales of $9.8 billion. Eaton is a global leader in fluid power systems and services for industrial, mobile and aircraft equipment; electrical systems and components for power quality, distribution and control; automotive engine air management systems and powertrain controls for fuel economy; and intelligent drivetrain systems for fuel economy and safety in trucks. Eaton has 55,000 employees and sells products to customers in more than 125 countries. For more information, visit www.eaton.com. Eaton Electric Limited Eaton Electric NV Reddings Lane PO Box 23 Birmingham B11 3EZ 7550 AA Hengelo United Kingdom The Netherlands Customer Support Centre Customer Support Centre Tel: +44 (0)8700 545 333 Tel: +31 (0)74 246 7066 Fax: +44 (0)8700 540 333 Fax: +31 (0)74 246 7070 email: ukcommorders@eaton.com email: c-heuropesupport@eaton.com © 2005 Eaton Electric Limited All rights reserved www.eatonelectrical.com Printed in UK Form No TDO3400001U April 2005
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2006:10:27 09:57:49+01:00 Modify Date : 2012:03:07 09:39:53Z Metadata Date : 2012:03:07 09:39:53Z Document ID : uuid:87d98b1e-15d4-470d-9815-ef447c149df6 Instance ID : uuid:69535c7c-6617-46f2-9ce0-94d6090ef618 Format : application/pdf Title : untitled Page Layout : SinglePage Page Mode : UseOutlines Page Count : 55EXIF Metadata provided by EXIF.tools