Product Detail Manual
109122-Brochure 109122-Brochure 109122-Brochure 080083 Batch7 unilog cesco-content
2014-07-04
: Pdf 593022-Attachment 593022-Attachment 080083 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Type Catalog # Project Comments SP15 & SP20, Heavy Duty Switchpacks Date Prepared by Can be easily mounted on or in a 4"sq. junction box, via ½” in nipple • Replaces separate transformers and relays • Zero-crossing circuit provides increased durability, especially with today’s high inrush loads • Capable of switching up to 20 Amps • Suitable for Plenum use • Rated for Ballast, Tungsten and Motor Loads Specifications: Electrical Ratings: Input: (120/277 VAC-SP20-MV), (347 VACSP15-347), (220-240 VAC-SP20-240), 50/60 Hz operation. Contacts are isolated and may be used to control low voltage circuits. Output: 15 VDC 125mA to operate up to five Greengate sensors Control: Connecting the 22 AWG red and blue control leads to each other will close the relay contacts Ballast Compatibility: Compatible with magnetic and electronic ballasts NOTE: The life of some compact fluorescent lamps (CFLs) is shortened by frequent automatic or manual switching. Check with the CFL and ballast manufacturer to determine effects of cycling. Operating Environment: • Temperature: 32°F to 104°F (0°C to 40°C) • Relative humidity: less than 95%, non-condensing • For indoor use only Housing: Medium impact injection molded housing. ABS resin complies with UL 94V-0. Plenum rated for external junction box mounting, with Teflon coated leads. Motor Load: 1 HP 120-240 VAC; 2 HP 250 VAC Size: 2 15/16” x 2 7/16” x 1 11/16” Mounting: Mounts to the side of a 4" square box via 1/2" knockout Available for 120, 220, 240, 277 & 347 VAC operation Overview Switchpacks provide 15 VDC operating voltage to all low voltage, 15 VDC occupancy sensors and daylighting controllers. A single switchpack can provide power for up to five sensors. Up to ten switchpacks can be connected to one sensor for control of multiple circuits. Isolated contacts may also be used to control HVAC, contactors, motors, etc. Description/Operation The switchpack has two main components: a transformer and one high current relay. The transformer has a primary line voltage input and a secondary low voltage output. The low voltage output, 15 VDC, provides operating power to connected low voltage Greengate occupancy sensors. When an occupancy sensor detects motion, it electrically closes an internal circuit, pulling up the control signal between the sensor and the switchpack. This signals the switchpack to close its high current relay, turning the connected load on. Application The switchpack is designed to work with low voltage sensors which require switchpacks. It cannot be used with sensors designed for use with any other low voltage relay systems. Consult sensor spec sheets for other sensor relay combinations. Ordering Catalog # Ratings Ballast Tungsten Motor (HP) SP20-MV 120/277 VAC, 50/60 Hz 20A 15A, 120V 1HP-120V, 2HP-250V 15 VDC, 125mA SP15-347 347 VAC, 50/60 Hz 15A NR NR 15 VDC, 125mA SP20-240 220-240 VAC, 50/60 Hz 20A NR NR 15 VDC, 125mA UL, CSA listed www.coopercontrol.com ACC131666 203 Cooper Circle Peachtree City, GA 30269 P: 800-553-3879 F: 800-954-7016 Output SP15 & SP20, Heavy Duty Switchpacks Wiring Diagrams A/B Switching Three Way Switching HOT HOT LINE 3. SWITCHES CAN BE USED TO TURN LOADS ON OR OFF. RECOMMENDED WIRE: 18-3 AWG STRANDED WIRE SHIELDED OR NON/SHIELDED RED (15 VDC) SWITCHPACK BLUE (CONTROL) LOAD "B" 2. LOAD TURNS OFF, WHEN SENSOR TIMES OUT. 3. SWITCHES CAN BE USED TO TURN LOADS ON OR OFF. BLUE RECOMMENDED WIRE: 18-3 AWG STRANDED WIRE SHIELDED OR NON/SHIELDED BLACK (COMMON) **USE BLACK LEAD FOR 120 VAC. USE ORANGE LEAD FOR 277 VAC. CAP UNUSED LEAD. RED (15 VDC) BLUE (CONTROL) WHITE LOAD "A" BLUE 1. WHEN SENSOR ACTIVATES, LOAD TURNS ON. WHITE **USE BLACK LEAD FOR 120 VAC. USE ORANGE LEAD FOR 277 VAC. CAP UNUSED LEAD. BLUE 2. LOADS TURN OFF, WHEN SENSOR TIMES OUT. **HOT 1. WHEN SENSOR ACTIVATES, LOADS TURN ON. NEUTRAL AUTOMATIC MODE OPERATION: NEUTRAL **HOT LINE AUTOMATIC MODE OPERATION: SWITCHPACK LOAD WALL BOX 1 WALL BOX 2 BLUE BLACK (COMMON) THREE-WAY SWITCHES RED (10-30 VDC) RED (10-30 VDC) TO ADDITIONAL SENSORS. MAXIMUM 5 SENSORS PER SWITCHPACK. BLUE (CONTROL) TO ADDITIONAL SENSORS. MAXIMUM 5 SENSORS PER SWITCHPACK. BLUE (CONTROL) BLACK (COMMON) BLACK (COMMON) 2 Circuits, 1 Sensor Standard Configuration HOT HOT AUTOMATIC MODE OPERATION: 1. WHEN SENSOR ACTIVATES, LOAD TURNS ON. LINE SWITCHPACK 1. WHEN SENSOR ACTIVATES, LOADS TURN ON. BLUE 2. LOADS TURN OFF, WHEN SENSOR TIMES OUT. BLACK (COMMON) BLUE (CONTROL) TO ADDITIONAL SENSORS. MAXIMUM 5 SENSORS PER SWITCHPACK. WHITE LINE NEUTRAL **USE BLACK LEAD FOR 120 VAC. USE ORANGE LEAD FOR 277 VAC. CAP UNUSED LEAD. BLACK (COMMON) LOAD "B" HOT 3. SWITCHES CAN BE USED TO TURN LOADS ON OR OFF. BLUE (CONTROL) BLUE BLACK (COMMON) RECOMMENDED WIRE: 18-3 AWG STRANDED WIRE SHIELDED OR NON/SHIELDED RED (10-30 VDC) BLUE BLUE (CONTROL) LOAD "A" SWITCHPACK RED (15 VDC) BLUE (CONTROL) BLACK (COMMON) WHITE RED (15 VDC) RED (15 VDC ) BLUE AUTOMATIC MODE OPERATION: **HOT BLUE **USE BLACK LEAD FOR 120 VAC. USE ORANGE LEAD FOR 277 VAC. CAP UNUSED LEAD. LOAD **HOT NEUTRAL **USE BLACK LEAD FOR 120 VAC. USE ORANGE LEAD FOR 277 VAC. CAP UNUSED LEAD. WHITE RECOMMENDED WIRE: 18-3 AWG STRANDED WIRE SHIELDED OR NON/SHIELDED NEUTRAL **HOT 2. LOAD TURNS OFF, WHEN SENSOR TIMES OUT. LINE SWITCHPACK BLUE TO ADDITIONAL SWITCHPACKS. MAXIMUM 10 SWITCHPACKS PER SENSOR. RED (10-30VDC) BLUE (CONTROL) BLACK (COMMON) Mounting All connections are made via pigtails with twist-on wire connectors. NOTE: Connect either the orange or black supply lead to the power source, depending upon the power requirements. Cap the unused lead. www.coopercontrol.com 203 Cooper Circle, Peachtree City, GA 30269 P: 800-553-3879 F: 800-954-7016 Cooper Controls, Greengate, Novitas, Yes Box, PCI Lighting Control Systems, VisionTouch, VisionSwitch, MicroSet, Digita, ControlKeeper, LiteKeeper, TracKeeper, IntelliRelay are valuable trademarks of Cooper Industries in the U.S and other countries. You are not permitted to use Cooper Trademarks without the prior written consent of Cooper Industries. TO ADDITIONAL SENSORS. MAXIMUM 5 SENSORS PER SWITCHPACK.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Create Date : 2013:10:22 14:16:56-04:00 Metadata Date : 2013:10:24 11:14:06-04:00 Modify Date : 2013:10:24 11:14:06-04:00 Creator Tool : Adobe InDesign CS5 (7.0.4) Page Image Page Number : 1, 2 Page Image Format : JPEG, JPEG Page Image Width : 256, 256 Page Image Height : 256, 256 Page Image : (Binary data 11993 bytes, use -b option to extract), (Binary data 7481 bytes, use -b option to extract) Instance ID : uuid:6ff2d13c-268c-4486-a2ed-69dcaeaaf1d6 Document ID : xmp.did:4C433B5C4E0FE3119AD09CF6A57290C5 Original Document ID : xmp.did:53F13F8F530EE311815AAF31C61A16C7 Rendition Class : proof:pdf History Action : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:53F13F8F530EE311815AAF31C61A16C7, xmp.iid:57F13F8F530EE311815AAF31C61A16C7, xmp.iid:58F13F8F530EE311815AAF31C61A16C7, xmp.iid:A63A38C76E0EE311815AAF31C61A16C7, xmp.iid:67DDEC487A0EE311815AAF31C61A16C7, xmp.iid:C9042A5C4E0FE3119AD09CF6A57290C5, xmp.iid:4C433B5C4E0FE3119AD09CF6A57290C5, xmp.iid:2BC9E268FD0FE311A7AC93DE8C04E259, xmp.iid:DE310EA16F16E311AF10FAB9A54DEF08, xmp.iid:304117E36F16E311AF10FAB9A54DEF08, xmp.iid:8EC7EF5AD335E311A8D59C605B8A4DF3, xmp.iid:3097AC60D335E311A8D59C605B8A4DF3, xmp.iid:3197AC60D335E311A8D59C605B8A4DF3, xmp.iid:DC5802091D38E311B13BCEFAF9193BEB, xmp.iid:DD5802091D38E311B13BCEFAF9193BEB, xmp.iid:3E568875453BE31187BDAAD49DC54B18, xmp.iid:446A6B88453BE31187BDAAD49DC54B18 History When : 2013:08:26 09:30:56-04:00, 2013:08:26 09:40:54-04:00, 2013:08:26 09:40:54-04:00, 2013:08:26 12:47:36-04:00, 2013:08:26 14:57:11-04:00, 2013:08:27 15:24:57-04:00, 2013:08:27 15:24:58-04:00, 2013:08:28 12:18:01-04:00, 2013:09:05 17:10:45-04:00, 2013:09:05 17:12:35-04:00, 2013:10:15 15:52:43-04:00, 2013:10:15 15:52:52-04:00, 2013:10:15 15:53:04-04:00, 2013:10:18 13:45:10-04:00, 2013:10:18 14:04:21-04:00, 2013:10:22 14:12:06-04:00, 2013:10:22 14:12:37-04:00 History Software Agent : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0 History Changed : /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata Derived From Instance ID : xmp.iid:C9042A5C4E0FE3119AD09CF6A57290C5 Derived From Document ID : xmp.did:53F13F8F530EE311815AAF31C61A16C7 Derived From Original Document ID: xmp.did:53F13F8F530EE311815AAF31C61A16C7 Derived From Rendition Class : default Doc Change Count : 45 Format : application/pdf Producer : Adobe PDF Library 9.9 Trapped : False State : 1 Version : 1.1 Page Count : 2 Creator : Adobe InDesign CS5 (7.0.4) Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools