Table of Contents

Section 23
Relays and Timers
s

General Purpose Relays

RXM, p. 23-8

RSL, p. 23-2 /RSB, p. 23-3

Zelio™ Interface Relays
Zelio™ Plug-in Relays, Sockets & Access.
Square D™ Plug-in
Square D™ Alternating Plug-in
Square D™ Miniature Plug-in
Square D™ Sockets
Square D™ Power

RSL, RSB
RXM, RPM, RUM, RPF
Class 8501 Type K
Class 8501 Type KA
Class 8501 Type R
Class 8501 Type N
Class 8501 Type C

23-2
23-4
23-10
23-11
23-12
23-14
23-15

TeSys D
TeSys K
TeSys SK
CA2SKE
Class 8501 Type X™

23-16
23-19
23-21
23-21
23-22

SSRP
SSRD
SSRAH1, SSRAT1

23-25
23-25
23-25

RE11
RE48
REXL
RE7, RE8, and RE9
Class 9050 Type JCK

23-26
23-26
23-26
23-27
23-30

REG24
REG48
REG96
RM17JC andRM35JA
RM17T and RM35T
RM17U and RM35U
RM35L
RM35BA
RM35S
RM35HZ
RM35AT

23-31
23-31
23-31
23-32
23-33
23-34
23-35
23-35
23-36
23-36
23-36

ABL1, ABL7, and ABL8
RM
SR2, SR3
ABS
ABR

23-37
23-38
23-39
23-41
23-42

Industrial Relays
TeSys™ IEC Style Relays

TeSys™ IEC Style - Alternating Relays
Square D™ NEMA Style Relays

Solid State Relays
SSR, p. 23-25

8501X, p. 23-22

Panel Mount
DIN Mount
SSR Accessories

Timers

CAD32, p. 23-16

9050JCK, p. 23-30

Zelio™ IEC Style—17.9 mm
Zelio™ Panel Mounting
Zelio™ Miniature Plug-in
Zelio™ IEC Style—22.5 mm
Square D™ General Purpose Plug-in

ABL8, p. 23-37

Other Products
REG24, REG48, REG96
p. 23-31

CA2SKE, p. 23-21

SR2, SR3, p. 23-39

RM17, RM35 p. 23-32

© 2012 Schneider Electric
All Rights Reserved

Phaseo™ DC Power Supplies
Zelio™ Analog Interface Modules
Zelio™ Logic 2 Smart Relays
Zelio™ Solid-State Interface Modules
Zelio™ Electromechanical Interface

23-1

23

RE7, p. 23-28

Zelio™ Temperature Controllers—24x48
Zelio™ Temperature Controllers—48x48
Zelio™ Temperature Controllers—48x96
Zelio™Current Measurement Relays
Zelio™ Phase Measurement Relays
Zelio™ Voltage Measurement Relays
Zelio™ Level Control Relays
Zelio™ Pump Control Relays
Zelio™ Speed Control Relays
Zelio™ Frequency Control Relays
Zelio™ Temperature Control Relays

RELAYS AND TIMERS

Control and Measurement Relays

General Purpose Relays

RSL
Refer to Catalog DIA3ED2090304EN-US

www.schneider-electric.us

Zelio™ Interface Relays
Zelio RSL slim interface relays save valuable panel space with a 6 mm width and have a 6 Amp general purpose load
rating. Features include:
• Pre-assembled option: relay and socket are combined into one catalog number.
• Universal AC/DC sockets have built-in protection from transients and reverse polarity voltages (see catalog
DIA3ED2090304EN-US for more detailed information).
• Accessories, which include isolators, ID tags, and bus jumper save valuable installation time.
Table 23.1:

Zelio RSL Slim Interface: Pre-assembled Relay + Socket (sold in lots of 10)
Socket Type

Socket Supply Voltage
(Vac/Vdc)

RSL 1PV••

RSL 1PR••

a

Table 23.3:

Catalog Numbera
RSL1PRJU
RSL1PRBU
RSL1PREU
RSL1PRFU
RSL1PRPU

$ Price ea.
12.00
15.70
16.10
16.10
16.10

Catalog No.
RSL1AB4JD
RSL1AB4BD
RSL1AB4ED
RSL1AB4ND
RSL1AB4ND

Zelio RSL Slim Interface: Relay Only (sold in lots of 10)
Relay Coil Voltage (Vdc)
12
24
48
60

RSL 1AB••

Catalog Number
RSL1AB4JD
RSL1AB4BD
RSL1AB4ED
RSL1AB4ND

$ Price ea.
6.20
7.70
7.90
7.90

Zelio RSL Slim Interface: Socket Only (sold in lots of 10)
Socket Type

Socket
Supply Voltage
(Vac/Vdc)

Screw Connector
Catalog Number

12
24
48
60
110
230

RSL ZVA•

Spring Terminal

Catalog Numbera
$ Price ea.
12
RSL1PVJU
12.00
24
RSL1PVBU
14.60
48
RSL1PVEU
14.90
110
RSL1PVFU
14.90
230
RSL1PVPU
14.90
Relays are mounted on sockets equipped with LED and protection circuit.

Table 23.2:

Replacement Relays

Screw Connector

Spring Terminal
$ Price ea.

Catalog Number

For use with relays:
$ Price ea.

RSLZVA1

7.20

RSLZRA1

8.30

RSLZVA2

7.20

RSLZRA2

8.30

RSLZVA3
RSLZVA4

7.40
7.40

RSLZRA3
RSLZRA4

8.60
8.60

RSL1AB4JD
RSL1AB4BD
RSL1AB4ED
RSL1AB4ND
RSL1AB4ND
RSL1AB4ND

RSL ZRA•

Table 23.4:

Socket Accessories

23

Description
ID tags (2 sheets of 64 tags)
Bus jumper (10 x 20-pole jumpers)
Butterfly isolator (10 isolators)

RSL Z2

Compatibility
With all sockets
With all sockets
With all sockets

Catalog Number
RSLZ5
RSLZ2
RSLZ3

$ Price ea.
4.60
3.80
3.70

Approvals for RSL relays:

RELAYS AND TIMERS

File
CCN

E173076
NRNT2,
NRNT8

File
Class

240278
3211 04

IEC
61810-1

RoHS
Compliant

247510
3211 07

IEC
RoHS
61810-1 Compliant

Approvals for RSLZ sockets:
RSL Z3
File
CCN

23-2

E172326S
SWIV2
SWIV8

File
Class

CP2

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

General Purpose Relays

RSB
Refer to Catalog DIA3ED2090304EN-US

www.schneider-electric.us

Zelio™ Plug-In Interface Relays
Zelio RSB interface relays and sockets provide the optimum combination of robust performance and space saving for
the most demanding applications. Relays are rated at 8 A, 12 A, and 16 A (250 Vac / 28 Vdc). Features include:
• Optional protection modules for protection against electrical spikes
• Optional plastic hold-down ejector clips
• Socket or printed circuit board installation options
Table 23.5:

Relays (sold in lots of 10)
Number and type of contacts - Thermal current (Ith)

Coil Voltage

1 C/O -16 A Res.

2 C/O -8 A Res.

Catalog Numbera
$ Price ea.
Catalog Numbera
$ Price ea.
Catalog Numbera
6 Vdc
RSB1A120RD
3.50
RSB1A160RD
4.20
RSB2A080RD
12 Vdc
RSB1A120JD
3.50
RSB1A160JD
4.20
RSB2A080JD
24 Vdc
RSB1A120BD
3.50
RSB1A160BD
4.20
RSB2A080BD
48 Vdc
RSB1A120ED
3.50
RSB1A160ED
4.20
RSB2A080ED
60 Vdc
RSB1A120ND
3.50
RSB1A160ND
4.20
RSB2A080ND
110 Vdc
RSB1A120FD
3.50
RSB1A160FD
4.20
RSB2A080FD
24 Vac
RSB1A120B7
3.50
RSB1A160B7
4.20
RSB2A080B7
48 Vac
RSB1A120E7
3.50
RSB1A160E7
4.20
RSB2A080E7
120 Vac
RSB1A120F7
3.50
RSB1A160F7
4.20
RSB2A080F7
220 Vac
RSB1A120M7
3.50
RSB1A160M7
4.20
RSB2A080M7
230 Vac
RSB1A120P7
3.50
RSB1A160P7
4.20
RSB2A080P7
240 Vac
RSB1A120U7
3.50
RSB1A160U7
4.20
RSB2A080U7
a
To order a relay complete with socket (sold in lots of 20): add suffix S to the catalog numbers selected above.
Example: RSB 2A080RD + RSZ E1S48M becomes RSB 2A080RDS.

Table 23.6:

Sockets – 12 A, 300 Vac
(sold in lots of 10)

Contact terminal arrangement

Relay type
RSB1A120••
Separate
Box lug connector
RSB1A160••b
RSB2A080••
b
When using the relay with socket RSZ E1S48M, terminals must be jumpered.

Table 23.7:
RSB2A080BD Relay
+ RSZE1S48M Socket

Connection

Catalog Number
RSZE1S35M

$ Price ea.
4.80

RSZE1S48M

5.30

Protection modules (sold in lots of 10)
Description

Diode

For use with
All sockets

RC circuit

All sockets

Diode + green LED

All sockets

Varistor + green LED

All sockets

Table 23.8:

$ Price ea.
4.20
4.20
4.20
4.20
4.20
4.20
4.20
4.20
4.20
4.20
4.20
4.20

Voltage
6–230 Vdc
24–60 Vac
110–240 Vac
6–24 Vdc
24–60 Vdc
110–230 Vdc
6–24 Vac/Vdc
24–60 Vac/Vdc
110–230 Vac/Vdc

Catalog Number
RZM040W
RZM041BN7
RZM041FU7
RZM031RB
RZM031BN
RZM031FPD
RZM021RB
RZM021BN
RZM021FP

$ Price ea.
2.40
4.80
4.80
4.20
4.20
6.00
6.00
6.00
6.00

Accessories (sold in lots of 10)

Description
Plastic hold-down ejector clip
ID tags

For use with
All sockets
All sockets

Catalog Number
RSZR215
RSZL300

$ Price ea.
.42
.30

Approvals for RSB relays:
RSB1A160BD Relay
+ RSZE1S48M Socket

File
CCN

E173076
NRNT2,
NRNT8

File
Class

215736
3211 07

IEC
61810-1

RoHS
Compliant

as of date
code 0401

212916
3211 07

RoHS
as of date
IEC 61984 Compliant
code 0501

RELAYS AND TIMERS

RSB1A120JD Relay
+ RZM031FPD Socket
+ RSZE1S35M Module

1 C/O -12 A Res.

File
CCN

SWIV2
E172326

File
Class

23

Approvals for RSB sockets:

RZM modules are RoHS compliant as of date code 0610.
For mounting track, see page 24-16.

© 2012 Schneider Electric
All Rights Reserved

CP2

Discount
Schedule

23-3

General Purpose Relays

RXM
Refer to Catalog DIA3ED2090304EN-US

Zelio™ Plug-In Relays

•

Zelio RXM miniature plug-in relays and sockets provide a
complete system solution in response to the most
demanding applications ranging from 3A to 12A. Some of
the features include:
• Test button with removable lock-down door for testing
the contacts (depending on model)

•
•
•

www.schneider-electric.us

Green LED indication of relay status (depending on
model)
Mechanical indication of relay status (standard)
Optional protection modules to protect against
electrical spikes
Bus jumpers for connecting multiple terminals reduce
installation time

IO

Table 23.9:

Miniature relays without LED, with Test Button and Lock-Down Door (sold in lots of 10)
Number and type of contacts - Thermal current (Ith)
2 C/O -12 A Res.

Coil Voltage
12 Vdc
24 Vdc
48 Vdc
110 Vdc
220 Vdc
24 Vac
48 Vac
120 Vac
230 Vac
240 Vac

Table 23.10:

Catalog Number
RXM2AB1JD
RXM2AB1BD
RXM2AB1ED
RXM2AB1FD
—
RXM2AB1B7
RXM2AB1E7
RXM2AB1F7
RXM2AB1P7
—

3 C/O - 10 A Res.
$ Price ea.
5.30
5.30
5.30
5.30
—
5.30
5.30
5.30
5.30
—

Catalog Number
RXM3AB1JD
RXM3AB1BD
RXM3AB1ED
RXM3AB1FD
—
RXM3AB1B7
RXM3AB1E7
RXM3AB1F7
RXM3AB1P7
—

4 C/O - 8 A Res.
$ Price ea.
5.70
5.70
5.70
5.70
—
5.70
5.70
5.70
5.70
—

Catalog Number
RXM4AB1JD
RXM4AB1BD
RXM4AB1ED
RXM4AB1FD
RXM4AB1MD
RXM4AB1B7
RXM4AB1E7
RXM4AB1F7
RXM4AB1P7
RXM4AB1U7

$ Price ea.
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00

Miniature relays with LED, Test Button, and Lock-Down Door (sold in lots of 10)
Number and type of contacts - Thermal current (Ith)
2 C/O -12 A Res.

RXM2AB2F7

Coil Voltage
12 Vdc
24 Vdc
48 Vdc
110 Vdc
125 Vdc
24 Vac
48 Vac
120 Vac
230 Vac

Table 23.11:

Catalog Number
RXM2AB2JD
RXM2AB2BD
RXM2AB2ED
RXM2AB2FD
—
RXM2AB2B7
RXM2AB2E7
RXM2AB2F7
RXM2AB2P7

3 C/O - 10 A Res.
$ Price ea.
6.20
6.20
6.20
6.20
—
6.20
6.20
6.20
6.20

Catalog Number
RXM3AB2JD
RXM3AB2BD
RXM3AB2ED
RXM3AB2FD
—
RXM3AB2B7
RXM3AB2E7
RXM3AB2F7
RXM3AB2P7

4 C/O - 8 A Res.
$ Price ea.
6.60
6.60
6.60
6.60
—
6.60
6.60
6.60
6.60

Catalog Number
RXM4AB2JD
RXM4AB2BD
RXM4AB2ED
RXM4AB2FD
RXM4AB2GD
RXM4AB2B7
RXM4AB2E7
RXM4AB2F7
RXM4AB2P7

$ Price ea.
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80

Miniature relays with LED, without Test Button and Lock-Down Door (sold in lots of 10)
Number and type of contacts - Thermal current (Ith)
2 C/O -12 A Res.

23

Coil Voltage
12 Vdc
24 Vdc
48 Vdc
110 Vdc
125 Vdc
24 Vac
48 Vac
120 Vac
230 Vac

Table 23.12:

Catalog Number
RXM2AB3JD
RXM2AB3BD
RXM2AB3ED
RXM2AB3FD
—
RXM2AB3B7
RXM2AB3E7
RXM2AB3F7
RXM2AB3P7

3 C/O - 10 A Res.
$ Price ea.
5.70
5.70
5.70
5.70
—
5.70
5.70
5.70
5.70

Catalog Number
—
—
—
—
—
—
—
—
—

RELAYS AND TIMERS

Miniature relays with low level contacts,
without LED, with Test Button and
Lock-Down Door (sold in lots of 10)

Table 23.14:

Number and type of contacts - Thermal current (Ith)

Table 23.13:
RXM4GB2F7

Catalog Number
RXM4AB3JD
RXM4AB3BD
RXM4AB3ED
RXM4AB3FD
RXM4AB3GD
RXM4AB3B7
RXM4AB3E7
RXM4AB3F7
RXM4AB3P7

$ Price ea.
6.30
6.30
6.30
6.30
6.30
6.30
6.30
6.30
6.30

Miniature relays with low level contacts,
with LED, without Test Button and
Lock-Down Door (sold in lots of 10)

Number and type of contacts - Thermal current (Ith)

4 C/O -3 A Res.
Coil Voltage
12 Vdc
24 Vdc
48 Vdc
110 Vdc
24 Vac
48 Vac
120 Vac
230 Vac

4 C/O - 8 A Res.
$ Price ea.
—
—
—
—
—
—
—
—
—

4 C/O -3 A Res.

Catalog Number
RXM4GB1JD
RXM4GB1BD
RXM4GB1ED
RXM4GB1FD
RXM4GB1B7
RXM4GB1E7
RXM4GB1F7
RXM4GB1P7

$ Price ea.
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00

Coil Voltage
12 Vdc
24 Vdc
48 Vdc
110 Vdc
125 Vdc
24 Vac
48 Vac
120 Vac
230 Vac

Catalog Number
RXM4GB3JD
RXM4GB3BD
RXM4GB3ED
RXM4GB3FD
—
RXM4GB3B7
RXM4GB3E7
RXM4GB3F7
RXM4GB3P7

$ Price ea.
6.30
6.30
6.30
6.30
—
6.30
6.30
6.30
6.30

Miniature relays with low level contacts,
with LED, Test Button and Lock-Down
Door (sold in lots of 10)

Number and type of contacts - Thermal current (Ith)
4 C/O -3 A Res.
Coil Voltage
12 Vdc
24 Vdc
48 Vdc
110 Vdc
24 Vac
48 Vac
120 Vac
230 Vac
240 Vac

Catalog Number
RXM4GB2JD
RXM4GB2BD
RXM4GB2ED
RXM4GB2FD
RXM4GB2B7
RXM4GB2E7
RXM4GB2F7
RXM4GB2P7
RXM4GB2U7

$ Price ea.
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80

For sockets and accessories, see page 23-5.
Approvals for Relays:

File
CCN a

a

23-4

E164862
NLDX, NLDX7

File
CCN

E164862
NLDX2,
NLDX8

File 230765
Class 3211 07

RoHS
IEC 61810-1 Compliant

When used with the appropriate socket.

CP2

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

General Purpose Relays

RXM
Refer to Catalog DIA3ED2090304EN-US

www.schneider-electric.us

Table 23.15:

Miniature relays (sold in lots of 100)
Number and type of contacts - Thermal current (Ith)
2 C/O - 12 A Res.
Coil Voltage

RXZE2M114M Socket +
RXM4AB2P7 Relay

Without LED, with Test Button, and Lock-Down Door
12 Vdc
24 Vdc
48 Vdc
110 Vdc
220 Vdc
24 Vac
48 Vac
120 Vac
230 Vac
With LED, Test Button, and Lock-Down Door
24 Vdc
24 Vac
230 Vac

Table 23.16:

4 C/O - 8 A Res.

Catalog Number

$ Price
ea.

Catalog Number

$ Price ea.

—
RXM2AB1BDTQ
—
—
—
RXM2AB1B7TQ
—
RXM2AB1F7TQ
RXM2AB1P7TQ

—
5.30
—
—
—
5.30
—
5.30
5.30

RXM4AB1JDTQ
RXM4AB1BDTQ
RXM4AB1EDTQ
RXM4AB1FDTQ
RXM4AB1MDTQ
RXM4AB1B7TQ
RXM4AB1E7TQ
RXM4AB1F7TQ
RXM4AB1P7TQ

6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00

—
RXM2AB2B7TQ
RXM2AB2P7TQ

—
6.20
6.20

RXM4AB2BDTQ
RXM4AB2B7TQ
RXM4AB2P7TQ

6.80
6.80
6.80

Miniature relays with LED without Test Button and Lock-Down Door (sold in lots of 100)
Number and type of contacts - Thermal current (Ith)
Coil Voltage

2 C/O - 12 A Res.
Catalog Number

24 Vdc
24 Vac
230 Vac

Table 23.17:

4 C/O - 8 A Res.
$ Price ea.

RXM2AB3BDTQ
RXM2AB3B7TQ
RXM2AB3P7TQ

5.70
5.70
5.70

Catalog Number
RXM4AB3BDTQ
RXM4AB3B7TQ
RXM4AB3P7TQ

$ Price
ea.
6.30
6.30
6.30

Sockets (sold in lots of 10)

Contact terminal arrangement

Connection

Relay type

Catalog Number

RXM2•••••a
RXZE2M114b
RXM4•••••a
RXM2
•••••
Box lug connector
RXZE2M114Mb
RXM4•••••
RXZE2S108Mc
RXM2•••••
Separate
Box lug connector
RXM3•••••
RXZE2S111Mb
RXM4•••••
RXZE2S114Mb
When mounting relay RXM2••••• on socket RXZE2M••••, the thermal current must not exceed 10 A.
Thermal current Ith: 10 A
Thermal current lth: 12 A
Screw clamp terminals

$ Price
ea.
5.00

Mixed

Protection modules (sold in lots of 10)

Description

RXZE2S114M Socket +
RXM4AB2F7 Relay

Voltage

Diode

6–250 Vdc
24–60 Vac
110–240 Vac
6–24 Vac/Vdc
24–60 Vac/Vdc
110–240 Vac/Vdc

RC circuit
Varistor

Table 23.19:

RXM040W
RXM041BN7
RXM041FU7
RXM021RB
RXM021BN
RXM021FP

$ Price
ea.
1.90
1.90
1.90
1.90
1.90
1.90

All sockets
All sockets
All sockets with separate contacts
All relays
All relays
All relays (sheet of 108 tags)
All sockets except RXZE2M114

Catalog Number
RXZ400
RXZR335
RXZS2
RXZE2DA
RXZE2FA
RXZL520
RXZL420

$ Price
ea.
.50
.50
.70
.70
.50
.10
.10

Approvals for Sockets:

File
CCN

© 2012 Schneider Electric
All Rights Reserved

All sockets
All sockets
All sockets
All sockets
All sockets
All sockets

For use with

Metal hold-down clip
Plastic hold-down ejector clip
Bus jumper, 2-pole (Ith: 5 A)
DIN rail mounting adapter
Panel mounting adapter
ID tags

RXZ400

Catalog Number

Accessories (sold in lots of 10)
Description

RXM041BN7

For use with

RELAYS AND TIMERS

Table 23.18:

5.00
5.00
5.00

23

a
b
c

5.00

E172326
SWIV2, SWIV8

CP2

File 230765
Class 3211 07

Discount
Schedule

IEC 61984

RoHS
Compliant

23-5

General Purpose Relays

RPM
Refer to Catalog DIA3ED2090304EN-US

www.schneider-electric.us

Zelio™ Plug-In Relays
Zelio RPM plug-in relays and sockets provide a complete system solution in response to the most demanding
applications up to 15 A. Some of the features include:
• Test button with removable lock-down door for testing the contacts (depending on model)
• Green LED indication of relay status (depending on model)
• Mechanical indication of relay status (standard)
• Optional modules to protect against electrical spikes
Table 23.20:

Power relays without LED, with Test Button and Lock-Down Door (sold in lots of 10)
Number and type of contacts - Thermal current (Ith)
1 C/O - 15 A Res.

RPM22F7

Coil Voltage
12 Vdc
24 Vdc
48 Vdc
110 Vdc
24 Vac
48 Vac
120 Vac
230 Vac

Catalog Number
RPM11JD
RPM11BD
RPM11ED
RPM11FD
RPM11B7
RPM11E7
RPM11F7
RPM11P7

Table 23.21:

2 C/O - 15 A Res.

$ Price ea.
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50

Catalog Number
RPM21JD
RPM21BD
RPM21ED
RPM21FD
RPM21B7
RPM21E7
RPM21F7
RPM21P7

$ Price ea.
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00

3 C/O - 15 A Res.
Catalog Number
RPM31JD
RPM31BD
RPM31ED
RPM31FD
RPM31B7
RPM31E7
RPM31F7
RPM31P7

4 C/O - 15 A Res.

$ Price ea.
8.10
8.10
8.10
8.10
8.10
8.10
8.10
8.10

Catalog Number
RPM41JD
RPM41BD
RPM41ED
RPM41FD
RPM41B7
RPM41E7
RPM41F7
RPM41P7

$ Price ea.
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00

Power relays with LED, Test Button and Lock-Down Door (sold in lots of 10)
Number and type of contacts - Thermal current (Ith)
1 C/O - 15 A Res.

RPM42BD

Coil Voltage
12 Vdc
24 Vdc
48 Vdc
110 Vdc
24 Vac
48 Vac
120 Vac
230 Vac

Catalog Number
RPM12JD
RPM12BD
RPM12ED
RPM12FD
RPM12B7
RPM12E7
RPM12F7
RPM12P7

Table 23.22:

2 C/O - 15 A Res.

$ Price ea.
5.30
5.30
5.30
5.30
5.30
5.30
5.30
5.30

Catalog Number
RPM22JD
RPM22BD
RPM22ED
RPM22FD
RPM22B7
RPM22E7
RPM22F7
RPM22P7

$ Price ea.
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80

3 C/O - 15 A Res.
Catalog Number
RPM32JD
RPM32BD
RPM32ED
RPM32FD
RPM32B7
RPM32E7
RPM32F7
RPM32P7

4 C/O - 15 A Res.

$ Price ea.
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00

Catalog Number
RPM42JD
RPM42BD
RPM42ED
RPM42FD
RPM42B7
RPM42E7
RPM42F7
RPM42P7

$ Price ea.
10.90
10.90
10.90
10.90
10.90
10.90
10.90
10.90

Power relays with LED, without Test Button and Lock-Down Door (sold in lots of 10)
Number and type of contacts - Thermal current (Ith)
1 C/O - 15 A Res.

23

Coil Voltage
12 Vdc
24 Vdc
48 Vdc
110 Vdc
125 Vdc
24 Vac
48 Vac
120 Vac
230 Vac

RELAYS AND TIMERS

Catalog Number
RPM13JD
RPM13BD
RPM13ED
RPM13FD
—
RPM13B7
RPM13E7
RPM13F7
RPM13P7

2 C/O - 15 A Res.

$ Price ea.
5.00
5.00
5.00
5.00
—
5.00
5.00
5.00
5.00

Catalog Number
RPM23JD
RPM23BD
RPM23ED
RPM23FD
—
RPM23B7
RPM23E7
RPM23F7
RPM23P7

$ Price ea.
6.30
6.30
6.30
6.30
—
6.30
6.30
6.30
6.30

3 C/O - 15 A Res.
Catalog Number
RPM33JD
RPM33BD
RPM33ED
RPM33FD
—
RPM33B7
RPM33E7
RPM33F7
RPM33P7

4 C/O - 15 A Res.

$ Price ea.
8.30
8.30
8.30
8.30
—
8.30
8.30
8.30
8.30

Catalog Number
RPM43JD
RPM43BD
RPM43ED
RPM43FD
—
RPM43B7
RPM43E7
RPM43F7
RPM43P7

$ Price ea.
10.10
10.10
10.10
10.10
—
10.10
10.10
10.10
10.10

Approvals for relays:

File
E164862
CCN a NLDX, NLDX7

a

RPZF2 Socket +
RPM22F7 Relay

File
CCN

E164862
NLDX2, NLDX8

File 230765
Class 3211 07

RoHS
IEC 61810-1 Compliant

When used with the appropriate socket

Table 23.23:

Sockets (sold in lots of 10)

Contact terminal arrangement

Mixed

Connection

Relay type
RPM1•••
RPM2•••
RPM3•••
RPM4•••

Screw terminals

Catalog Number
RPZF1
RPZF2
RPZF3
RPZF4

$ Price ea.
4.30
5.50
6.30
7.30

Approvals for Sockets:
File
CCN

23-6

E172326
SWIV2, SWIV8

CP2

File 230765
Class 3211 07

Discount
Schedule

IEC 61984

RoHS
Compliant

© 2012 Schneider Electric
All Rights Reserved

General Purpose Relays

RPM
Refer to Catalog DIA3ED2090304EN-US

www.schneider-electric.us

Protection modules (sold in lots of 10)

Description
Diode

Voltage
6–250 Vdc

RXM041BN7
24–60 Vac
RC circuit
110–240 Vac

6–24 Vac/Vdc
24–60 Vac/Vdc
Varistor

110–240 Vac/Vdc
24 Vac/Vdc
240 Vac/Vdc

Table 23.25:

For use with
RPZF1
RPZF2
RPZF3
RPZF4
RPZF1
RPZF2
RPZF1
RPZF2
RPZF3
RPZF4
RPZF1
RPZF2
RPZF1
RPZF2
RPZF1
RPZF2
RPZF3
RPZF4
RPZF3
RPZF4

1.90

RUW240BD

2.60

RXM041BN7

1.90

RXM041FU7

2.20

RUW241P7

2.20

RXM021RB

1.90

RXM021BN

1.90

RXM021FP

1.90

RUW242B7

2.70

RUW242P7

2.70

Catalog Number

RUW101MW

$ Price

47.10

Accessories (sold in lots of 10)

Description
Metal hold-down clip (for single-pole relays)
DIN rail mounting adapter b

Panel mounting adapter

RPZ1DA

$ Price ea.

RXM040W

Timer modulea (sold in lots of 1)

Description
Voltage
For Use With
On-delay timer, interval timer,
repeat cycle timer/starting on-delay,
RPZF3
repeat cycle timer/starting off-delay,
24–240 Vac/Vdc
RPZF4
off-delay timer, one-shot timer,
timing on de-energization, on-delay timer
a
See timer module description (selection of functions and time delays) in catalog DIA3ED2090304EN-US.

Table 23.26:

Catalog Number

ID tags (sheet of 108 tags)
b
Test button and lock-down door become inaccessible

For use with
RPZF1
RPM1•••
RPM2•••
RPM3•••
RPM4•••
RPM1•••
RPM2•••
RPM3•••
RPM4•••
All relays

Catalog Number
RPZR235
RPZ1DA
RXZE2DA
RPZ3DA
RPZ4DA
RPZ1FA
RXZE2FA
RPZ3FA
RPZ4FA
RXZL520

$ Price ea.
0.50
0.70
0.70
0.70
0.70
0.50
0.50
0.50
0.50
0.10

RELAYS AND TIMERS

Table 23.24:

23

RPZ3FA

© 2012 Schneider Electric
All Rights Reserved

CP2

Discount
Schedule

23-7

General Purpose Relays

RUM
Refer to Catalog DIA3ED2090304EN-US

www.schneider-electric.us

Zelio™ Plug-In Relays
Zelio RUM plug-in relays and sockets provide a complete system solution in response to the most demanding
applications up to 16 A. Some of the features include:
• Test button with lock-down door for testing the contacts (depending on model)
• Green LED indication of relay status (depending on model)
• Mechanical indication of relay status (standard)
• Optional protection modules to protect against electrical spikes
• Bus jumpers for connecting multiple terminals reduce installation time

Table 23.27:

Relays for standard applications without LED, with Test Button and Lock-Down Door
(sold in lots of 10)
Number and type of contacts - Thermal current (Ith)

Pins

Coil Voltage
12 Vdc
24 Vdc
48 Vdc
60 Vdc
110 Vdc
125 Vdc
220 Vdc
24 Vac
48 Vac
120 Vac
230 Vac
12 Vdc
24 Vdc
48 Vdc
110 Vdc
24 Vac
48 Vac
120 Vac
230 Vac

Cylindrical

Flat

Table 23.28:

2 C/O -16 A Res.
Catalog Number
RUMC2AB1JD
RUMC2AB1BD
RUMC2AB1ED
—
RUMC2AB1FD
—
—
RUMC2AB1B7
RUMC2AB1E7
RUMC2AB1F7
RUMC2AB1P7
RUMF2AB1JD
RUMF2AB1BD
RUMF2AB1ED
RUMF2AB1FD
RUMF2AB1B7
RUMF2AB1E7
RUMF2AB1F7
RUMF2AB1P7

3 C/O -16 A Res.
$ Price ea.
10.10
10.10
10.10
—
10.10
—
—
10.10
10.10
10.10
10.10
10.10
10.10
10.10
10.10
10.10
10.10
10.10
10.10

Catalog Number
RUMC3AB1JD
RUMC3AB1BD
RUMC3AB1ED
RUMC3AB1ND
RUMC3AB1FD
RUMC3AB1GD
RUMC3AB1MD
RUMC3AB1B7
RUMC3AB1E7
RUMC3AB1F7
RUMC3AB1P7
RUMF3AB1JD
RUMF3AB1BD
RUMF3AB1ED
RUMF3AB1FD
RUMF3AB1B7
RUMF3AB1E7
RUMF3AB1F7
RUMF3AB1P7

$ Price ea.
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30

Relays for standard applications, with LED, Test Button, and Lock-Down Door
(sold in lots of 10)
Number and type of contacts - Thermal current (Ith)

Pins

Coil Voltage

23

12 Vdc
24 Vdc
48 Vdc
60 Vdc
110 Vdc
125 Vdc
24 Vac
48 Vac
120 Vac
230 Vac
12 Vdc
24 Vdc
48 Vdc
110 Vdc
24 Vac
48 Vac
120 Vac
230 Vac

Cylindrical

RUMF3AB2P7
Universal Relay

RELAYS AND TIMERS

Flat

Table 23.29:

2 C/O -16 A Res.
Catalog Number
RUMC2AB2JD
RUMC2AB2BD
RUMC2AB2ED
—
RUMC2AB2FD
—
RUMC2AB2B7
RUMC2AB2E7
RUMC2AB2F7
RUMC2AB2P7
RUMF2AB2JD
RUMF2AB2BD
RUMF2AB2ED
RUMF2AB2FD
RUMF2AB2B7
RUMF2AB2E7
RUMF2AB2F7
RUMF2AB2P7

3 C/O -16 A Res.
$ Price ea.
11.30
11.30
11.30
—
11.30
—
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30
11.30

Catalog Number
RUMC3AB2JD
RUMC3AB2BD
RUMC3AB2ED
RUMC3AB2ND
RUMC3AB2FD
RUMC3AB2GD
RUMC3AB2B7
RUMC3AB2E7
RUMC3AB2F7
RUMC3AB2P7
RUMF3AB2JD
RUMF3AB2BD
RUMF3AB2ED
RUMF3AB2FD
RUMF3AB2B7
RUMF3AB2E7
RUMF3AB2F7
RUMF3AB2P7

$ Price ea.
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50

Relays for standard applications with LED, without Push Button, and Lock-Down Door
(sold in lots of 10)
Number and type of contacts - Thermal current (Ith)

Pins

Coil Voltage
12 Vdc
24 Vdc
48 Vdc
60 Vdc
110 Vdc
125 Vdc
24 Vac
48 Vac
120 Vac
230 Vac
12 Vdc
24 Vdc
48 Vdc
110 Vdc
125 Vdc
24 Vac
48 Vac
120 Vac
230 Vac

Cylindrical

Flat

2 C/O -16 A Res.
Catalog Number
RUMC2AB3JD
RUMC2AB3BD
RUMC2AB3ED
—
RUMC2AB3FD
—
RUMC2AB3B7
RUMC2AB3E7
RUMC2AB3F7
RUMC2AB3P7
RUMF2AB3JD
RUMF2AB3BD
RUMF2AB3ED
RUMF2AB3FD
—
RUMF2AB3B7
RUMF2AB3E7
RUMF2AB3F7
RUMF2AB3P7

3 C/O -16 A Res.
$ Price ea.
10.40
10.40
10.40
—
10.40
—
10.40
10.40
10.40
10.40
10.40
10.40
10.40
10.40
—
10.40
10.40
10.40
10.40

Catalog Number
RUMC3AB3JD
RUMC3AB3BD
RUMC3AB3ED
RUMC3AB3ND
RUMC3AB3FD
RUMC3AB3GD
RUMC3AB3B7
RUMC3AB3E7
RUMC3AB3F7
RUMC3AB3P7
RUMF3AB3JD
RUMF3AB3BD
RUMF3AB3ED
RUMF3AB3FD
RUMF3AB3GD
RUMF3AB3B7
RUMF3AB3E7
RUMF3AB3F7
RUMF3AB3P7

$ Price ea.
11.60
11.60
11.60
11.60
11.60
11.60
11.60
11.60
11.60
11.60
11.60
11.60
11.60
11.60
11.60
11.60
11.60
11.60
11.60

Approvals for Relays:
File
CCN a

a

23-8

E164862
NLDX,
NLDX7

File
CCN

E164862
NLDX2,
NLDX8

File 230765
Class 3211 07

IEC 61810-1

RoHS
Compliant

When used with appropriate socket

For sockets and accessories, see
page 23-9

© 2012 Schneider Electric
All Rights Reserved

General Purpose Relays

RUM
Refer to Catalog DIA3ED2090304EN-US

www.schneider-electric.us

Table 23.30:

Sockets (sold in lots of 10)

Contact terminal arrangement

Connection

Relay type
Catalog Number
RUMC2•••••
RUZC2M
RUMC3•••••
RUZC3M
RUMC2•••••
RUZSC2M
Box lug connector
(screw terminals)
RUMC3•••••
RUZSC3M
Separate b
RUMF2•••••
RUZSF3M
RUMF3•••••
a
The inputs are mixed with the relay coil terminals, with the outputs located on the opposite side of the socket.
b
The inputs and outputs are separated from the relay coil terminals.

$ Price ea.
3.50
4.20
4.50
5.00

Mixed a

RUZ C3M Socket+
RUMC3ppppp Relay

Table 23.31:

Protection modules (sold in lots of 10)

Description

For use with

Diode
RC circuit

All sockets

Varistor

RUW241P7

Table 23.32:

RUW101MW

RUZS2

Voltage
6–250 Vdc
110–240 Vac
24 Vac/Vdc
240 Vac/Vdc

Catalog Number
RUW240BD
RUW241P7
RUW242B7
RUW242P7

$ Price ea.
2.20
2.20
2.70
2.70

Timer modulec (sold in lots of 1)

Description
For use with
Voltage
On-delay timer, interval timer,
repeat cycle timer/starting on-delay,
repeat cycle timer/starting off-delay,
All sockets
24–240 Vac/Vdc
off-delay timer, one-shot timer,
timing on de-energization, on-delay timer.
c
See timer module description (selection of functions and time delays) in catalog 8501CT0601.

Table 23.33:

5.60

Catalog Number

$ Price

RUW101MW

47.10

Accessories (sold in lots of 10)

Description
Metal hold-down clip
Bus jumper, 2-pole (Ith: 5 A)

For use with
All sockets
All sockets with separate contacts
All relays (sheet of 108 tags)
All sockets with separate contacts

ID tags

Catalog Number
RUZC200
RUZS2
RXZL520
RUZ420

$ Price ea.
1.20
0.70
0.10
0.10

Approvals for Sockets:
RUZC200
File
CCN

E172326
SWIV2, SWIV8

File
Class

230765
3211 07

RoHS
Compliant

IEC 61810-1

RELAYS AND TIMERS

Zelio™ RPF Power Relays
RPF Zelio power relays respond to the most demanding applications up to 30 A. Features include:
• UL Listed
• Sealed construction
• Motor load ratings: 1hp @ 120 Vac / 3hp @ 240 Vac (N/O contacts only)
• Dual DIN rail and panel mounting capability
• Short circuit rating of 5,000 A @ 240 Vac (N/O contacts only)
Table 23.34:

Power relays (sold in lots of 10)
Number and type of contacts - Thermal current (Ith)

RPF2BJD

2 C/O - 30 A on N.O. / 3 A on N.C. a Res.

2 N/O - 30 Aa Res.

Catalog Number
12 Vdc
RPF2AJD
24 Vdc
RPF2ABD
110 Vdc
RPF2AFD
24 Vac
RPF2AB7
120 Vac
RPF2AF7
230 Vac
RPF2AP7
a
30 A when mounted with 13 mm gap between two relays.
25 A when mounted side by side without a gap.

$ Price ea.
10.40
10.40
10.40
10.40
10.40
10.40

Catalog Number
RPF2BJD
RPF2BBD
RPF2BFD
RPF2BB7
RPF2BF7
RPF2BP7

$ Price ea.
10.90
10.90
10.90
10.90
10.90
10.90

23

Coil Voltage

Approvals for Relays:
File
CCN

E43641
NLDX, NLDX7

File 040787
Class 3211-07

IEC 61810-1

RoHS
Compliant

For mounting track, see page 24-16

© 2012 Schneider Electric
All Rights Reserved

CP2

Discount
Schedule

23-9

General Purpose Relays

Type K
Class 8501 / Refer to Catalog 8501CT0301

www.schneider-electric.us

Square D™ Plug-In Relays
8501K relays are designed for multipole switching applications at
240 Vac or lower. These relays have industry standard wiring and pin
terminal arrangements which allow for their use as replacements for
many competitive relays without wiring or hardware modifications.

•
•
•

12 A relays
DPDT or 3PDT
Manual operator/
green pilot light options

Table 23.35:

•
•

Motor load (hp) ratings
DPDT latching models
available
AC or DC operation
RoHS Compliant

•
•

Contact
Arrangement

Options

Type

DPDT

AC
50/60 Hz

24.60

3PDT

KF13d

26.70

DPDT

KFD12d

24.60

KFD13d

26.70

Contact
Arrangement
DPDT

DC

23

KP12
KP12P14
KP13
KP13P14
KU12
KU12M1

AC
50/60
Hz

DC

None Available

AC
50/60 Hz

Voltage
Codes

$ Price

Table 23.39:

Type KL—Latching Relay—Spade Terminals
Input
Voltage

DPDT

Options

Type

None Available

None Available

12

24

120

240

Type

45.00

DC Voltage
6

12

24

48

110

125

V35 V36 V14 V20 V24 Voltage Codes V50 V51 V53 V56 V60 V63
S

S
S
S
S

S
S
S
S
S

S
S
S
S
S

S
S
S
S
S

KPD12
KPD12P14
KPD13
KPD13P14
KUD12
KUD12M1

S

S
S
S

S
S
S
S

S
S

S
S

S
S
S

S
S

RELAYS AND TIMERS

KU12P14
S
S
KUD12P14
S
KU12M1P14
S
S
KUD12M1P14
S
KU13
S
S
S
S
KUD13
S
S
S
KU13M1
KUD13M1
KU13P14
S
S
KUD13P14
KU13M1P14
S
S
S
KUD13M1P14
S
S
KF12
S
S
S
KFD12
S
S
KF13
S
S
KFD13
S
KL12
S
S
KLD12
S
S
Note: S = Stocked.
Factory order items require a minimum order quantity of 25 and have a lead time of 12
weeks.

Table 23.40:

Type
KP
KU
KFd
KL
Note:
a
b
c
d

File 211269
Class 3211 04

For 8501 KP, KU, and KL:
File
CCN

E78351
NLDX
NLDX7

•
•
•

39.00
45.00
47.30
53.30
39.00
45.00
47.30
53.30

Type

$ Price
22.70

KU12M1d

26.70

KU12P14d

28.70

KU12M1P14d

30.80

KU13d

24.60

KU13M1d

28.70

KU13P14d

30.80

KU13M1P14d

35.00

KUD12d

22.70

KUD12M1d

26.70

KUD12P14d

28.70

KUD12M1P14d

30.80

KUD13d

24.60

KUD13M1d

28.70

KUD13P14d

30.80

KUD13M1P14d

35.00

Contact Ratings (Contacts are Silver Tin Oxide)

AC
Volts
120
240
120
240
120
240

DC

Resistive 75% PF
Continuous
Amperes
10 c
6.5 b
12
12
10
10

Hp
1/3
1/2
1/3
1/2
1/3
1/2

DC
Volts

Resistive
Amperes

28

12

28

12

28

10

All 8501 K relays have a B300 rating.
Socket is not required with Type KF relays.
3 pole devices have a 20 A max. total (sum of currents in all 3 poles), continuous rating.
3 pole devices have a 30 A max. total (sum of currents in all 3 poles), continuous rating.
Voltage code must be specified to order this product. Refer to standard voltage codes
listed in Table 23.37 and insert as shown in Table 23.41: How to Order.

Table 23.41:
When used with the appropriate 8501NR socket.

$ Price

KU12d

AC

For 8501 KP, KU, and KF:
File E78351
CCN NLDX2
NLDX8

Type
KP12d
KP12P14d
KP13d
KP13P14d
KPD12d
KPD12P14d
KPD13d
KPD13P14d

Contact
Options
Arrangement
DPDT
None
Manual
DPDT
Operator
DPDT
Pilot Light
Manual
DPDT
Operator and
Pilot Light
AC
50/60 Hz
3PDT
None
Manual
3PDT
Operator
3PDT
Pilot Light
Manual
3PDT
Operator and
Pilot Light
DPDT
None
Manual
DPDT
Operator
DPDT
Pilot Light
Manual
DPDT
Operator and
Pilot Light
DC
3PDT
None
Manual
3PDT
Operator
3PDT
Pilot Light
Manual
3PDT
Operator and
Pilot Light

45.00

KLD12d

Options
None
Pilot Light
None
Pilot Light
None
Pilot Light
None
Pilot Light

Input
Voltage

$ Price

KL12d

Contact
Arrangement
DPDT
DPDT
3PDT
3PDT
DPDT
DPDT
3PDT
3PDT

Type KU—Spade Terminals

Voltage Codes and Stocked Relays
AC Voltage 50/60 Hz

6

Input
Voltage

KF12d

3PDT

Type

Type KP—Tubular Terminals

None Available

DC

Table 23.37:

Table 23.38:

Type KF —Flange Mounted—Spade Terminals
Input
Voltage

Table 23.36:

Pilot Light Option—Available on Types KP and KU. Internal pilot lights
are available in both AC and DC versions for positive indication of power
to the coil. The pilot light is a green LED.
Manual Operator Option—Available on Type KU only. To facilitate
speed circuit testing, a manual operator (test button) can be provided.
Coil VAC—3.0 VA
Coil VDC—1.4 Watts

How to Order

To Order Specify:
Class Number
Type Number
Voltage Code
(See Stocked Relay Table above)

Catalog Number
Class

Type

Voltage
Code

8501

KP12

V20

For 8501 KL:
File E78351
CCN NLDX2
NLDX8

23-10

For sockets and accessories, see page 23-14.
For track, see page 24-16.
File 211268
Class 3211 04

CP2

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

General Purpose Relays

8501KA
Refer to Catalog 8501CT9401

www.schneider-electric.us

Square D™ Alternating Plug-In Relays
8501KA alternating relay is designed to minimize pump and motor wear by equalizing run time between parallel
components in a multi-pump system.
The relay is controlled by an external control switch. The switch may be any type of contact closure; for example the
contacts of a timing relay or the closure of a float switch. The 8501KA relay also has a toggle switch that allows the
operator to lock one side of the duplex system in the “on” position.

•
•
•
•

12 A Resistive Rating
SPDT or DPDT
Toggle switch for load control
LED Load Indicators

Table 23.42:

Horsepower Rated
AC and DC Control
UL Listed w/ Square D Socket
Rohs Compliant

Type KA — Alternating Relay
Options

Type

AC & DC
AC & DC
AC & DC

Contact
Arrangement
SPDT
DPDT
DPDT (N.C.)

LED + Toggle
LED + Toggle + Cross Wired
LED + Toggle

8501KA81•••
8501KA82•••
8501KA112•••

93.00
95.00
94.00

AC & DC

DPDT (N.O.)

LED + Toggle

8501KA112A•••

94.00

Input Voltage

Table 23.43:

$ Price

Relay Availability
AC & DC Voltage

Type
Voltage Code

AC Voltage

12

24

120

240

V36

V14

V20

V24

8501KA81•••
8501KA82•••
8501KA112•••
8501KA112A•••

•
•
•

S
S
S
S

Table 23.44:

Notes:
AC Voltage is 50/60 Hz
S = Stocked. “S” items have a 2 week lead time and
nominimum order requirement.
All other part numbers are considered factory order
(FO) and require a minimum order quantity of 25 and
have a lead-time of 18 weeks

Contact Ratings
AC

Type

AC Volts
120
240

8501KA81•••

Table 23.45:

Resistive
Amperes
12
12

DC
HP

Pilot Duty

DC Volts

Resistive
Amperes

1/3
1/2

—
B300

30

12

Alternating Functions

Diagram

Toggle Switch Position
Detail
S1 = Control Switch 1
S2 = Control Switch 2
LA = Load 1
LB = Load 2
Alternate
Closing S1 alternates the loads between LA and LB.
Lock 1
LA is ON and LB is OFF. S1 is not used in this mode.
Lock 2
LA is OFF and LB is ON. S1 is not used in this mode.
Alternate
Closing S1 alternates the loads between LA an dLB. S2 will only control LA.
Lock 1
S1 will control LA and S2 will control LB
Lock 2
S1 will control LB and S2 will control LA.
The cross wired option allows extra system load capacity through simultaneous operation of both motors when needed (LA and LB energize
simultaneously when both S1 and S2 are closed–relay contacts are not isolated)
Input voltage must applied at all times for proper alternation. Use of a solid state control switch for S1 or S2 may not initiate alternation corredtly.
S1 or S2 voltage must be from the same supply as the unit’s input voltage (see wiring diagrams). Loss of input voltage resets the unit; LA becomes
the lead load for the next operation.

A, C & D

B

ALL

Wiring Diagrams and Dimensions
C.

23

A.

RELAYS AND TIMERS

•
•
•
•

···

8501KA112

8501KA81

B.

D.

···

8501KA112A

8501KA82

Socket = 8501NR51 or NR52

Approvals

File
Class

© 2012 Schneider Electric
All Rights Reserved

···

Socket = 8501NR61 or NR62

Socket = 8501NR51 or NR52

···

Socket = 8501NR61 or NR62

E78351
NLDX

E78351
NLDX2

CP2

Discount
Schedule

File
Class

242675
3211-07

IEC 61810-1

23-11

General Purpose Relays

Type R
Class 8501 / Refer to Catalog 8501CT0301

Square D™ Miniature Plug-in Relays
8501R miniature plug-in relays have a 10 A resistive
rating, the same as the Type K plug-in relays, but
are much smaller. The compact size of these relays
makes them ideal for downsizing equipment and
applications where space is at a premium.

•
•
•
•

•

SPDT through 4PDT
AC or DC operated
Horsepower rated
Socket compatible

Table 23.48:

SPDT with Silver Tin Oxide Contacts
Input
Voltage

Options

Type

None
AC
50/60
Hz

Manual operator/
green LED pilot
light options
Silver tin oxide
contacts

•

www.schneider-electric.us

29.60

Manual Operator

RS41M1b

31.70

Pilot Light

RS41P14b

37.20

RS41M1P14b

39.30

RSD41b

29.60

Manual Operator

RSD41M1b

31.70

Pilot Light

RSD41P14b

37.20

RSD41M1P14b

29.60

Manual Operator and Pilot Light
None
DC

Manual Operator and Pilot Light

Table 23.46:

Contact Ratings
(Contact material is Silver Tin Oxide)
Resistive
Rating

Voltage

General Use
Rating

120 Vac
15
8501RS41 a
240 Vac
12
8501RSD41a
28 Vdc
15
120 Vac
10
8501RS42a
240 Vac
10
8501RSD42a
30 Vdc
10
120 Vac
10
8501RS43a
277 Vac
10
8501RSD43a
28 Vdc
10
120 Vac
10
8501RS44a
277 Vac
10
8501RSD44a
28 Vdc
10
a
Relays have a B300 rating with UL.

120 Vac
240 Vac
28 Vdc
120 Vac
240 Vac
28 Vdc
150 Vac
250 Vac
28 Vdc
150 Vac
250 Vac
28 Vdc

10
10
15
10
10
10
10
6.6
10
7.5
5
10

Type

Table 23.47:
Type

Table 23.49:

Voltage

1/3
1/3
—
1/3
1/2
—
—
—
—
—
—
—

6

12

24

120

240

Type

AC
50/60
Hz

@120 Vac
@240 Vac

35.00

RS42M1b

37.10

Pilot Light

RS42P14b

43.10

RS42M1P14b

45.20

RSD42b

35.00

Manual Operator

RSD42M1b

37.10

Pilot Light

RSD42P14b

43.10

RSD42M1P14b

45.20

None

@120 Vac
@240 Vac

DC

Manual Operator and Pilot Light

Table 23.50:

3PDT with Silver Tin Oxide Contacts
Input
Voltage

Options

Type

None
AC
50/60
Hz

DC Voltage
12

24

39.30

Manual Operator

RS43M1b

41.40

Pilot Light

RS43P14b

47.60

RS43M1P14b

49.90

RSD43b

39.30

Manual Operator

RSD43M1b

41.40

Pilot Light

RSD43P14b

47.60

RSD43M1P14b

49.90

None
110
DC

Manual Operator and Pilot Light

Table 23.51:

$ Price

RS43b

Manual Operator and Pilot Light
6

$ Price

Manual Operator

4PDT with Silver Tin Oxide Contacts

23

Input
Voltage

Options

Type

None
AC
50/60
Hz

RELAYS AND TIMERS

44.30

Manual Operator

RS44M1b

46.20

Pilot Light

RS44P14b

52.30

RS44M1P14b

54.50

RSD44b

44.30

Manual Operator

RSD44M1b

46.20

Pilot Light

RSD44P14b

52.30

Manual Operator and Pilot Light
None
DC

$ Price

RS44b

RSD44M1P14b
54.50
Manual Operator and Pilot Light
Voltage code must be specified to order this product. Refer to standard voltage codes
listed in Table 23.47 and insert as shown in Table 23.53: How to Order.

b

Application Data

Class 8501 Type
RS41
RSD41
RS42
RSD42
RS43
Pick-Up Time
20 ms Maximum
25 ms Maximum
Operating Data
Drop-Out Time
20 ms Maximum
Operating Temperature -40oC to +70oC (-40oF to +158oF)
Duty Cycle
Continuous
Voltage Range
AC coils +10%, -15% of nominal DC coils +10%, -20% of nominal
Coil
AC Coils–Inrush
9 VA
—
6.2 VA
—
10.3 VA
AC Coils–Sealed
1.5 VA
—
1.2 VA
—
1.7 VA
DC Coils
—
0.9 watts
—
0.9 watts
—
File E78351
UR
CCN NLDX2, NLDX8
File 211268
CSA
Class 3218 07
CE marked
yes
RoHS Compliant
yes
File E78351c
UL Listed
CCN NLDX, NLDX7
c
When used with the appropriate 8501NR socket.

Table 23.53:

RSD43

—
—
1.4 watts

•
•
•

CP2

Class Number
Type Number
Voltage Code (see Table 23.47)

Discount
Schedule

RS44
RSD44
20 ms Maximum

11.9 VA
2.1 VA
—

—
—
1.5 watts

How to Order

To Order Specify:

For sockets and accessories, see page 23-14.
For track, see page 24-16.

23-12

Type
RS42b

Manual Operator and Pilot Light

Voltage Code V35 V36 V14 V20 V24
Voltage Code V50 V51 V53 V60
RS41
S
S
RSD41
S
S
RS41M1
RSD41M1
RS41P14
S
S
RSD41P14
S
RS41M1P14
S
S
RSD41M1P14
S
RS42
S
S
S
S
RSD42
S
S
RS42M1
RSD42M1
RS42P14
S
S
RSD42P14
S
S
RS42M1P14
S
RSD42M1P14
S
RS43
S
S
RSD43
S
RS43M1
RSD43M1
RS43P14
S
RSD43P14
RS43M1P14
S
RSD43M1P14
RS44
S
S
S
RSD44
S
S
RS44M1
RSD44M1
RS44P14
S
RSD44P14
S
RS44M1P14
S
RSD44M1P14
Note: S = Stocked.
Factory order items require a minimum order quantity of 25 and have a lead time of 12
weeks.

Table 23.52:

Options
None

Voltage Codes and Stocked Relays
AC Voltage 50/60 Hz

DPDT with Silver Tin Oxide Contacts
Input
Voltage

Horsepower
Rating

$ Price

RS41b

Catalog Number
Class

Type

8501

RS42

Voltage
Code
V20

© 2012 Schneider Electric
All Rights Reserved

General Purpose Relays

Type R
Class 8501 / Refer to Catalog 8501CT0301

www.schneider-electric.us

Pilot Light Option

8501R relays are suited for use as logic elements and
power switching output devices. The short stroke motion of
the armature provides long mechanical life required for
high speed operation of control systems. Different contact
compositions allow these relays to be used in a variety of
applications. Fine silver (gold flashed) and bifurcated
crossbar (gold overlay silver) are suitable for high contact
reliability and low level switching requirements. Silver tin
oxide is best suited for inductive loads. Class I Division II
sealed relays can be used in specified hazardous
locations.

An internal green pilot light is available in both AC and DC
versions for positive indication of power to the coil.

Table 23.54:
5A
For
switching
inductive
loads

Contacts:
Silver Tin
Oxide

8501RS14M1V14

Input
Voltage

DC

Input
Voltage

For low level
switching

AC
50/60
Hz

DC

Options

Table 23.57:

Type

$ Price

RS14a
RS14M1a
RS14P14a

32.70
35.00
40.90

RS14M1P14a

43.10

RSD14a
RSD14M1a
RSD14P14a

27.70
30.80
36.80

RSD14M1P14a

39.00

Type

None
Manual Operator
Pilot Light
Manual Operator
and Pilot Light
None
Manual Operator
Pilot Light
Manual Operator
and Pilot Light

$ Price

RS4a
RS4M1a
RS4P14a

32.70
35.00
40.90

RS4M1P14a

43.10

RSD4a
RSD4M1a
RSD4P14a

28.70
30.80
36.80

RSD4M1P14a

39.00

Type
RS24a

DC

RSD24a

$ Price
53.00
53.00

5 A Version, Class I Division II

AC Voltage Codes and Stocked Relays
AC Voltage 50/60 Hz

Type

6

12

24

48

120

240

V35

V36

V14
S

V17

V24

S

S

V20
S
S
S
S
S
S
S
S
S
S

RS4
RS4M1
RS4P14
RS4M1P14
RS14
RS14M1
RS14P14
RS14M1P14
RS24
RS34

Table 23.60:

S

DC Voltage Codes and Stocked Relays
DC Voltage
6

12

24

48

110

Voltage Code
V50
V51
V53
V56
V60
RSD4
S
S
RSD4M1
RSD4P14
S
RSD4M1P14
S
RSD14
S
S
S
RSD14M1
S
RSD14P14
S
S
S
RSD14M1P14
S
S
RSD24
S
RSD34
S
S
Note: S = Stocked.
Factory Order items require a minimum order quantity of 25 and have
a lead time of 12 weeks.

Application Data
RS4

RSD4

Pick-Up Time
Drop-Out Time
Operating Temperature
Range
Duty Cycle

RS14

RSD14

RS24

RSD24

RS34

RSD34

20 ms Maximum
20 ms Maximum

13 ms Max.
6 ms Max.

-40oC to +70oC (-40oF to +158oF)

-40oC to +70oC (-40oF to +158oF)

Continuous

Voltage Range

AC coils +10%, -15% of nominal and DC coils +10%, -20% of nominal

Coil

AC Coils—Sealed
1.2 VA
—
AC Coils—Inrush
6.2 VA
—
DC Coils
—
0.9 watt
UR
File: E197072
C UR US
File: E197072
CSA
File: 211268
Approvals
CE marked
Yes
RoHS Compliant
Yes
UL Listed
File E78351
d
When used with the appropriate 8501 NR Socket.
For sockets and accessories, see page 23-14.

© 2012 Schneider Electric
All Rights Reserved

Table 23.59:

Type

Input Voltage
AC 50/60 Hz

Class 8501 Type
Operating
Data

Horsepower
Rating

120/240 Vac
3
1/10
30 Vdc
3
—
120/240 Vac
5
1/6
RS14c
RSD14c
28 Vdc
5
—
120/240 Vac
1
1/16 (2.8 FLA)
RS24
RSD24
30 Vdc
1
—
120/240 Vac
5
—
RS34
RSD34
30 Vdc
5
—
c
RS4/RSD4, RS14/RSD14 have NEMA C300 pilot duty rating.

1 A Version

5 A, Hermetically Sealed
Input Voltage
Type
$ Price
5 Ampere Resistiveb
AC
50/60
Hz
RS34a
53.00
Silver Tin Oxide Contacts
Suitable for Class I
DC
RSD34a
53.00
Division 2 Locations
a
Voltage code must be specified to order this product. Refer to standard
voltage codes shown in Table 23.59.
b
Do not ground the frame.

Table 23.61:

Continuous
Current Rating

Voltage

Voltage Code

Options

1A
Best for Low Level Switching
Bifurcated Silver Gold-Plated
Contacts

Contact Ratings
(Contact material is Silver Tin Oxide)

Type

3 A Version

3A

Table 23.58:

RS4 c
RSD4c

None
Manual Operator
Pilot Light
Manual Operator
and Pilot Light
None
Manual Operator
Pilot Light
Manual Operator
and Pilot Light

AC
50/60
Hz

Table 23.56:

Horsepower rated
AC or DC operation
Manual operator/pilot
light options

5 A Version

Table 23.55:

Contacts:
Fine Silver
(Gold
Flashed)

8501RSD34V51

•
•
•

1, 3, or 5 A versions
4PDT
Complete socket line

To speed circuit testing, a manual operator (test button)
can be provided. The relay can be manually switched to
simulate normal operation.
NOTE: All Type R relays with a manual operator must
be used on circuits of the same polarity.

CP2

Discount
Schedule

1.2 VA
6.2 VA
—

—
1.2 VA
—
—
6.2 VA
—
0.9 watt
—
0.9 watt
CCN: NRNT2
CCN: NRNT8 (Approved but not marked)
Class: 3218 07

1.2 VA
6.0 VA
—

RELAYS AND TIMERS

•
•
•

Manual Operation Option

23

8501RSD14P14V53

Square D™ Miniature Plug-in Relays

—
—
0.9 watt

N/A
File: E196809 CCN: NQMJ2, NQMJ8
File: 211268 Class: 3218 06

CCN NLDX, NLDX7d
For track, see page 24-16.

23-13

General Purpose Relays

Type N
Class 8501 / Refer to Catalog 8501CT0301

www.schneider-electric.us

Square D™ Sockets

8501NR51

8501NR61

8501NR sockets are designed for use with plug-in Class 8501 Type K, KA, and R relays,
and 9050JCK timers. The 8501NR45 screw terminal sockets have pressure wire clamps
that accept 1 or 2 #16–22 wires. All other sockets have pressure clamps that will accept 1
or 2 #12–22 wires.
The recommended tightening torque for all terminals is 7-8 lb-in.
• All devices stocked in central warehouse
• DIN track mount or direct panel mount
• Tubular sockets available in easy-to-wire single tier or double tier versions
• RoHS compliant
Table 23.62:

Snapmount Sockets

For Use
With Class:

Socket Rating

8501
Type

8501NR62

8501NR52

9050
Type
JCK11–19
JCK31–39
JCK51–59
JCK60
JCK1 F
JCK3 F
JCK5 F
JCK21–29
JCK41–49
JCK70
JCK2F
JCK4F

KP12
KPD12
KA81
KA82

KP13
KPD13
KA112
KL
KU
RS41
RSD41

8501NR45

8501NR82

RS42
RSD42
RS43
RSD43
RS44
RSD44

23
8501NR42

8501NR41

Description

Type
UL

8 Pin Tubular
Single Tier Screw Terminal
8 Pin Tubular
Double Tier Screw Terminal

CSA

600 V, 10 A
300 V, 15 A
600 V, 5 A
300 V, 16 A

300 V, 10 A

300 V, 10 A

11 Pin Tubular
Double Tier Screw Terminal

600 V, 5 A
300 V, 15 A
600 V, 5 A
300 V, 16 A

—

11 Pin Spade
Double Tier Screw Terminal

300 V, 15 A

300 V, 15 A

—

5 Pin Spade
Double Tier Screw Terminal

300 V, 15 A

300 V, 15 A

—

8 Pin Spade
Double Tier Screw Terminal

300 V, 10 A

300 V, 10 A

—

11 Pin Spade
Double Tier Screw Terminal

300 V, 10 A

300 V, 10 A

—

14 Pin Spade
Double Tier Screw Terminal

300 V, 10 A

300 V, 10 A

11 Pin Tubular
Single Tier Screw Terminal

300 V, 10 A
300 V, 10 A

$ Price Std.
ea.
Qty.a

NR51
NR51B
NR52b

12.30
10.20
12.30

1
10
1

NR52Bb

10.20

10

NR61
NR61B
NR62b
NR62Bb
NR82
NR82B
NR41b
NR41Bb
NR42
NR42B
NR43
NR43B
NR34
NR34B

18.50
16.50
18.50
16.50
20.60
18.50
28.70
26.70
28.70
26.70
26.70
26.70
28.70
26.70

1
10
1
10
1
10
1
10
1
10
1
10
1
10

RS4
RSD4
NR45
28.70
1
RS14
RSD14
14 Pin Spade
—
300
V,
10
A
300
V,
10
A
RS24
Double Tier Screw Terminal
RSD24
NR45B
26.70 10
RS34
RSD34
a
Must be ordered in multiples of the quantity listed. Units provided in standard quantity of one are individually
packaged; devices with B suffix have a standard quantity of 10 per bulk pack.
b
Finger Safe

RELAYS AND TIMERS

For DIN 3 mounting track and end clamps, see page 24-16, or refer to:
• NEMA Style terminal block section of catalog 9080CT9601
• IEC Style terminal block section of catalog 9080CT9901
Table 23.63:
Socket

Socket Accessories
For Use With

8501NH7

8501NR34

1.00
8.30
1.00
8.30
1.00
8.30
1.00
8.30
1.00
—
1.00
1.00
1.00

10
1
10
1
10
1
10
1
10
—
10
10
10

8501NH45

1.00

10

Approvals:

To Order Specify:

Catalog Number

Class Number
Type Number

Class

Type

8501

NR51B

23-14

$ Price ea. Std. Pack c

Type
NH51
NH7
NH52
NH7
NH61
NH7
NH52
NH7
NH82
Supplied with socket as standard
8501NH42
8501NH42
8501NH42

8501NR43

How to Order
•
•

Description

8501KP12, KPD12
Hold Down Clip
9050JCK
Hold Down Spring
8501KP12, KPD12
Hold Down Clip
8501NR52
9050JCK
Hold Down Spring
8501KP13, KPD13
Hold Down Clip
8501NR61
9050JCK
Hold Down Spring
8501KP13, KPD13
Hold Down Clip
8501NR62
9050JCK
Hold Down Spring
8501NR82 8501KU and KL
Hold Down Clip
8501NR41 8501RS41, RSD41
Hold Down Clip
8501NR42 8501RS42, RSD42
Hold Down Clip
8501NR43 8501RS43, RSD43
Hold Down Clip
8501NR34 8501RS44, RSD44
Hold Down Clip
8501RS4, RSD4
8501RS14,
RSD14
8501NR45 8501RS24, RSD24
Hold Down Clip
8501RS34, RSD34
c
Must be ordered in multiples of the quantity listed.
8501NR51

File
CCN

E66924
SW1V2

File
Class

211268
3211 07

RoHS
Compliant

as of date
code 0639

IEC 61984

CP2

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

General Purpose Relays

Type C
Class 8501 / Refer to Catalog 8501CT1003

www.schneider-electric.us

Square D™ Power Relays
8501C relays are ideally suited for controlling single-phase motors, electric heaters, pumps, conveyors, material
handling equipment, and other applications.

•
•
•

•
•

40 A contact rating
Motor load (hp) ratings

•
•

UL listed
CSA certified

CE approved
RoHS compliant

Durable open-frame construction

8501CDO6V51

Table 23.64:

Selection Table and Application Data
Selection Table
Number
of Fixed
Contacts

Contact
Arrangement

N.O.

Application Data

AC Operated Coil
Open Type

DC Operated Coil
Open Type

N.C.

Type

Type

$ Price

Maximum
Single Phase
Horsepower

Resistive Ampere
Rating 75% Power Factor

Maximum
Contact
Voltage

$ Price

277 Vac

600 V

120 V

230 V

Maximum
Coil Power
Consumption
600 V

AC Coil

DC Coil

AC Rated Contacts
SPST

1

0

CO6a

32.70

CDO6a

32.70

600

40

10

2

2

2

10 VA

4W

DPST

2

0

CO7a

51.30

CDO7a

51.30

600

40

5

1.5

1.5

1.5

10 VA

4W

SPST

0

1

CO8a

32.70

CDO8a

32.70

600

40

10

2

2

2

10 VA

4W

SPDT

1

1

CO15a

57.30

CDO15a

57.30

600

40

5

1.5

1.5

1.5

10 VA

4W

DPDT

2

2

CO16a

69.60

CDO16a

69.60

600

40

5

1.5

1.5

1.5

10 VA

4W

110 V

220 V
10 VA

4W

10 VA

4W

DC Rated Contacts
1

0

CO21a

71.70

CDO21a

71.70

500

20

8

2

2

CO22a

84.00

CDO22a

84.00

325

10

4

N.A.

Voltage codes must be specified to order this product. Refer to standard voltage codes listed in Table 23.66 and insert as shown in Table 23.68: How to Order.

Table 23.65:

Operating Data

Table 23.66:

AC coils – 6 through 480 volts, + 10/-15% of nominal at 25 oC
DC coils – 6 through 110 volts, + 10/-20% of nominal at 25 oC

Operating Voltages/
Voltage Range
Coil Duty

Continuous duty rated coils. (Non-replaceable)

Operating Temp. Range

AC: -67 oF to +131 oF (-55 oC to +55 oC)
DC: -67 oF to +131 oF (-55 oC to +55 oC)

Storage Temp. Range

-67 oF to +212 oF (-55 oC to +100 oC)

Voltage Codes and Stocked Relays

Class
8501
Type

6

12

AC Voltage—50/60 Hz
24

120

208

240

277

480

Class
8501
Type

6

12

24

110

Voltage
Code

V35

V36

V14

V20

V08

V24

V04

V29

Voltage
Code

V50

V51

V53

V60

CO6

S

S

S

S

S

S

S

CDO6

S

S

CO7

S

S

S

S

S

S

S

CDO7

S

S

S

S

S

S

S

CDO8

S

S

S

S

S

S

CDO15

S

S

S

S

S

S

CDO16

S

S

S

S

S

CO8

Approvals:

CO15
File E78351
CCN NLDX

CO16

File 218139
Class 3211 04

IEC 60947-4-1

S

CO21

S

DC Voltage

S

CDO21

CO22
S
CDO22
S
S
Note: S = Stocked.
Factory order items require a minimum order quantity of 25 and have a lead time of
12 weeks.

Approximate Dimensions and Wiring Diagrams
8501CO16, 8501CDO16, 8501CO22, 8501CDO22 (DPDT)

8501CO15, 8501CDO15 (SPDT)

14

A1

2.06
(52.4)

A1 21

14

A2 11

2.31
(58.8)

2.5
(63.6)

1.874
(47.60)

0.374
(9.50)

0.81
(20.7)

0.19
(4.8)

2.49
(63.2)

12

A2 11

0.374
(9.50)

2.5
(63.6)

1.874
(47.60)

8501CO6, 8501CDO6, 8501CO8, 8501CDO8, 8501CO21, 8501CDO21 (SPST)

14

12

0.19
(4.8)

3.13
(79.4)

8501CO7, 8501CDO7 (DPST)

A1

1.98
(50.3)

23

0.31
(8.0)

24

22

24

A1 21

14

A2 11

1.95
(49.6)

2.5
(63.6)

Table 23.67:

1.874
(47.60)

13

2.49
(63.2)

A2

2.5
(63.6)

Class 9991 Enclosure

Type

Description

UE1

NEMA 1 sheet steel enclosure

© 2012 Schneider Electric
All Rights Reserved

Table 23.68:
$ Price

•
•
•

29.60

CP2

Discount
Schedule

1.874
(47.60)

2.49
(63.2)

How to Order

To Order Specify:
Class Number
Type Number
Voltage Code
(See Stocked Relay Table above)

Catalog Number
Class

Type

Voltage
Code

8501

CO6

V20

RELAYS AND TIMERS

a

SPST
DPDT

23-15

Industrial Relays

CAD
Refer to Catalog 8501CT0101

www.schneider-electric.us

TeSys™ D IEC Style Relays
These 600 volt relays are approved for use around the world. TeSys D relays are usually mounted on 35 mm DIN 3
track, but can also be mounted directly to a panel. The fixed contacts in these relays have a NEMA A600 and Q600
ratings, in addition to the standard IEC ratings, making them suitable for use in most any control circuit. Low
consumption versions of this relay are available for use with low level DC signals from a computer or a PLC. Adder
decks can be added to a basic five pole relay to make it up to an 11 pole relay. The serrated silver-nickel contacts with
wiping action provide excellent reliability in 12 or 24 volt control circuits. Special auxiliary contacts are available for
switching low power down to 5 volts at 10 mA. Timer and mechanical latch attachments are available.
Table 23.69:

Instantaneous Control Relays
Contact Composition
Normally Open

Terminal Type

$ Price

Normally Closed

Number of Contacts

Catalog Number
DC or Low
Consumption Coil

AC Coil

CAD32
Screw Clamp
Spring Terminal

5

Ring Tongue

5
5

a

5
3
5
3
5
3

5

0
2
0
2
0
2

CAD50a
CAD32a
CAD503a
CAD323a
CAD506a
CAD326a

Instantaneous Auxiliary Contact Blocks (for use in normal operation environments)
Maximum Number per Device
Clip-on Mounting

Number of
Contacts

Contact Composition
Termination Type

Front

Normally Open

Normally Closed

23
RELAYS AND TIMERS

b
c

2
0
1
1
0
2
1
—
2
0
2
Spring Terminal
1
1
0
2
2
0
1
—
Not for
Screw Clamp
1
1
DC devices
0
2
4
0
3
1
2
2
Screw Clamp
1
3
0
4
4b
1
—
4
0
3
1
Spring Terminal
2
2
1
3
0
4
Screw Clamp
2c
2c
4b
1
—
Spring Terminal
2c
2c
Auxiliary contact blocks with four contacts cannot be used on relays with low consumption coils.
Includes 1 N.O. and 1 N.C. overlapping contact.

Table 23.71:

Catalog Number

$ Price

Left Side Only
LADN20
LADN11
LADN02
LADN203
LADN113
LADN023
LAD8N20
LAD8N11
LAD8N02
LADN40
LADN31
LADN22
LADN13
LADN04
LADN403
LADN313
LADN223
LADN133
LADN043
LADC22
LADC223

Screw Clamp

CAD323

110.00
110.00
110.00
110.00
110.00
110.00

Add the proper voltage code from Table 23.72 to the end of catalog number (for example, CAD50B7).

Table 23.70:

CAD503

62.00
62.00
62.00
62.00
62.00
62.00

20.70
20.70
20.70
20.70
20.70
20.70
20.70
20.70
20.70
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50

Instantaneous Auxiliary Contacts with Dust and Damp Protected Contacts
(for use in particularly harsh industrial environments)

Approvals:

Contact Composition

File
CCN

E164353
NKCR

Number
of Contacts

Maximum Number
per Device

Catalog Number

Sealed
d
Normal
2
—
—
—
—
2
1
—
2
—
—
—
2
—
2
—
—
2
—
—
2
—
4e
1
2
—
—
1
1
Grounding terminal points (2 terminals jumpered together; see diagram on page 8 of Catalog 8501CT0101).
Auxiliary contact blocks with four contacts cannot be used on relays with low consumption coils.

$ Price

Front Mounting

File LR43364
Class 3211 03
d
e

Table 23.72:

LA1DX20
LA1DX02
LA1DY20
LA1DZ40
LA1DZ31

65.00
65.00
77.00
82.00
82.00

Coil Voltage Codes f

AC 50/60 Hz Coil (for additional voltage code options see page 7 of Catalog 8501CT0101).
Volts
12
24
48
120
208
240
277
Code
J7
B7
E7
G7
LE7
U7
W7
DC Coil (coils have built in suppression as standard)
Volts
12
24
36
48
60
72
110
Code
JD
BD
CD
ED
ND
SD
FD
DC Low Consumption Coil (coils have built in suppression as standard)
Volts
5
12
24
48
72
Code
AL
JL
BL
EL
SL
f
Add the proper voltage code to the end of catalog number.

480
T7

600
X7

125
GD

220
MD

250
UD

440
RD

For replacement AC coils, see page 18-16. DC coils are not replaceable.
23-16

I12

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Industrial Relays

CAD
Refer to Catalog 8501CT0101

www.schneider-electric.us

TeSys™ D IEC Style
Table 23.73:

Time Delay Auxiliary Contact Blocks

Number and Type
of Contacts

Maximum Number
per Device

Time Delay Type

Termination Type

Screw Clamp
On-Delay
1 N.C. and 1 N.O.

1

Spring Terminal

LADT
Screw Clamp
Off-Delay
Spring Terminal

(Lockout Cover,
See page 7 of Catalog 8501CT0101.)
a
b

LADT0
LADT2
LADT4
LADS2
LADT03
LADT23
LADT43
LADS23
LADR0
LADR2
LADR4
LADR03
LADR23
LADR43

Maximum Number per Device

131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00

Catalog Number

Front mounting

$ Price

LA6DK10 ed
77.00
LAD6K10 e
77.00
Power should not be simultaneously applied or maintained to the mechanical latching block and the CAD relay. The duration of the control signal to the
mechanical latching block and the CAD relay should be Š 100 ms.
Repair part for the preceeding version (non-TeSys) of this product. Not for use on CAD devices.
Complete the catalog number by adding coil voltage code from Table 23.76. (for example, LA6DK10B)
Manual or electrical

d
e

0.1–3 s a
0.1–30 s
10–180 s
1–30 s b
0.1–3 s a
0.1–30 s
10–180 s
1–30 s b
0.1–3 s a
0.1–30 s
10–180 s
0.1–3 s a
0.1–30 s
10–180 s

$ Price

Mechanical Latch Blocks c
Unlatching Control

LA6DK

Catalog Number

With extended scale from 0.1 to 0.6 s.
With switching time of 40 ms ± 15 ms between opening of the N.C. contact and closing of the N.O. contact.

Table 23.74:

c

Range

Front Mounting

Table 23.75:

1

Coil Suppressor Modules

These modules clip onto the right hand side of the control relay and the electrical connection is instantly made. Adding an input
module is still possible.
RC Circuits (Resistor-Capacitor)

•
•
•

Effective protection for circuits highly sensitive to “high frequency” interference.
Voltage limited to 3 Uc maximum and oscillating frequency limited to 400 Hz maximum.
Slight increase in drop-out time (1.2 to 2 times the normal time).
For Mounting On:

Operational Voltage

Catalog Number
LAD4RCE
LAD4RCU

24 to 48 Vac
110 to 240 Vac

CAD (Vac)

$ Price
26.20
26.20

LAD4

Protection provided by limiting the transient voltage value to 2 Uc maximum.
Maximum reduction of transient voltage peaks.
Slight increase in drop-out time (1.1 to 1.5 times the normal time).
24 to 48 Vac
50 to 127 Vac
110 to 250 Vac

CAD (Vac)

LAD4VE
LAD4VG
LAD4VU

26.20
26.20
26.20

LAD4TB
LAD4TS

26.20
26.20

Bidirectional Peak Limiting Diode

Protection provided by limiting the transient voltage value to 2 Uc maximum.
Maximum reduction of transient voltage peaks.
24 Vac
72 Vac

CAD (Vac)

Table 23.76:

Coil Voltage Codes

Voltage

24
Vac/Vdc

32/36
Vac/Vdc

42/48
Vac/Vdc

60/72
Vac/Vdc

100
Vac/Vdc

110/127
Vac/Vdc

220/240
Vac/Vdc

256/277
Vac/Vdc

380/415
Vac/Vdc

Voltage Code

B

C

E

EN

K

F

M

U

Q

CAD (Vdc Coil) or (Low Consumption Vdc Coil)

b

b

CAD (Vac Coil)

c

0.49
12.5
(LAD-8)

c1
c2

1.77
45

c

1.77
45

c1
c2
c3

c3

in. (mm)

b

© 2012 Schneider Electric
All Rights Reserved

Without cover or add-on blocks
With cover, without add-on blocks

in. (mm)

32
50

323
503

3.03 (77)
3.31 (84)
3.39 (86)

3.90 (99)
3.31 (84)
3.39 (86)

CAD

c

23

•
•

RELAYS AND TIMERS

Varistors (Peak Limiting)

•
•
•

I12

Discount
Schedule

CAD
b
c

Without cover or add-on blocks
With cover, without add-on blocks

32
50

323
503

3.03 (77)
3.66 (93)
3.74 (95)

3.90 (99)
3.66 (93)
3.74 (95)

23-17

Industrial Relays

CAD
Refer to Catalog 8501CT0101

www.schneider-electric.us

TeSys™ D IEC Style Relays
Table 23.77:

Cabling Accessory
Description

Catalog Number

Without coil suppression
Mounting Adapter
For adapting existing wiring
to a new product

Table 23.78:
•

With coil suppression

$ Price

LAD4BB

23.00

24 to 48 Vac

LAD4BBVE

23.00

50 to 127 Vac

LAD4BBVG

23.00

110 to 250 Vac

LAD4BBVU

23.00

Electronic Serial Timer Modules a

Mounted using adaptor LAD4BB, to be ordered separately, see listing above.

On-delay Type
Operational Voltage

24 to 250 Vac
a

Time Delay

Catalog Number

0.1 to 2 s

LA4DT0U

$ Price
82.00

1.5 to 30 s

LA4DT2U

82.00

25 to 500 s

LA4DT4U

82.00

For 24 V operation, the relay must be fitted with a 21 V coil (code Z7).

Table 23.79:

Auto-Man-Stop Control Modules

For local override operation tests with two-position “Auto-Man” switch and “O-I” switch

•

Mounted using adaptor LAD4BB, to be ordered separately, see listing above.
Operational Voltage

Catalog Number

24 to 100 Vac

Table 23.80:

$ Price

LA4DMK

35.00

Accessories (ordered separately)

For Connection
For Mounting On:

Must be Ordered in
Multiples of:

Catalog Number

Sheet of 64 self-adhesive blank labels 8 x 33

CAD, LAD (4 contacts), LA6DK

10

LAD21

5.20

Sheet of 112 self-adhesive blank labels 8 x 12

LAD (2 contacts), LADT

10

LAD22

5.20

LADT, LADR

1

LA9D901

5.50

1

LAD9ET1

5.20

Description

$ Price ea.

For Marking

23

For Protection
Lockout cover

Relay cover preventing access to the moving contact carrier CAD

RELAYS AND TIMERS

Table 23.81:

Application Data
Type

CAD (Vac)

CAD (Vdc)
Low Consumption

Conforming to IEC 60947-1-1
Overvoltage category III and degree of pollution 3

690 V

690 V

690 V

Conforming to UL, CSA

600 V

600 V

600 V

Rated Impulse Withstand Voltage
(Uimp)

Conforming to IEC 60947-1-1

6 kV

6 kV

6 kV

Separation of Electrical Circuits

To IEC 536 and VDE 0106

Rated Insulation Voltage (Ui)

Reinforced insulation up to 400 V
IEC 60947-1-1, N-F C 63-140, VDE 0660, BS 4794.
EN 60947-5-15

Conforming to Standards

UL: File:
E164353
CCN: NKCR
CSA: File:
Class: 3211 03
LR43364 CE

Approvals

23-18

CAD (Vdc)

Protective Treatment

Conforming to IEC 68

“TH” (Tropical Finish). See page 23 of Catalog 8501CT0101 for details.

Degree of Protection

Conforming to VDE 0106

Front face protected against direct finger
contact IP 2X

I12

Discount
Schedule

Protection against direct
finger contact

© 2012 Schneider Electric
All Rights Reserved

Industrial Relays

CA2K and CA3K
Refer to Catalog 8501CT0101

www.schneider-electric.us

TeSys™ K IEC Style Relays
Table 23.82:
•
•

Control Relays
•
•

Mounting on 35 mm DIN 3 track or 4 screw direct mounting.
Screws in open “ready-to-tighten” position.

Control Circuit

Supply

CA2KN22 • •

CA2KN403 • •

a

NEMA A600, Q600
IEC AC15, DC13
Contact Configuration

Type of
Termination

Catalog Number a

Consumption

N.O.

$ Price

N.C.

4
0
CA2KN40 • •
Screw clamp
3
1
CA2KN31 • •
2
2
CA2KN22 • •
4
0
CA2KN403 • •
Spring Termination
3
1
CA2KN313 • •
2
2
CA2KN223 • •
AC
4.5 VA
4
0
CA2KN407 • •
Faston
1 x 6.35
3
1
CA2KN317 • •
or 2 x 2.8
2
2
CA2KN227 • •
4
0
CA2KN405 • •
Solder pins for
printed circuit
3
1
CA2KN315 • •
board
2
2
CA2KN225 • •
4
0
CA3KN40 • •
Screw clamp
3
1
CA3KN31 • •
2
2
CA3KN22 • •
4
0
CA3KN403 • •
Spring Termination
3
1
CA3KN313 • •
2
2
CA3KN223 • •
DC
3W
4
0
CA3KN407 • •
Faston
1 x 6.35
3
1
CA3KN317 • •
or 2 x 2.8
2
2
CA3KN227 • •
4
0
CA3KN405 • •
Solder pins for
printed circuit
3
1
CA3KN315 • •
board
2
2
CA3KN225 • •
Complete catalog number by adding proper voltage code from Table 23.84 or Table 23.85 (for example, CA2KN40G7).

Table 23.83:

35.50
35.50
35.50
35.50
35.50
35.50
35.50
35.50
35.50
35.50
35.50
35.50
49.20
49.20
49.20
49.20
49.20
49.20
49.20
49.20
49.20
49.20
49.20
49.20

Low Consumption Control Relays

Compatible with programmable controller outputs.
Mounting on 35 mm DIN 3 track or 4 screw direct mounting.
Screws in open “ready-to-tighten” position.

4
0
CA4KN40 • ••
3
1
CA4KN31 • • •
2
2
CA4KN22 • • •
4
0
CA4KN403 • ••
Spring Termination
3
1
CA4KN313 • ••
2
2
CA4KN223 • ••
DC
1.8 W
4
0
CA4KN407 • ••
Faston
1 x 6.35
3
1
CA4KN317 • ••
or 2 x 2.8
2
2
CA4KN227 • ••
4
0
CA4KN405 • ••
Solder pins for
3
1
CA4KN315 • ••
printed circuit board
2
2
CA4KN225 • ••
Complete catalog number by adding proper voltage code from Table 23.86 (for example, CA4KN40BW3).

64.00
64.00
64.00
64.00
64.00
64.00
64.00
64.00
64.00
64.00
64.00
64.00

Screw clamp

CA4KN405 • • •

a

Table 23.84:
Vac
50/60 Hz

12

Coil Voltage Codes for CA2K Control Relays (0.8–1.15 Uc) (0.85–1.1 Uc)
24

36

42

48

110

120

127

208

220/
230

230

230/
240

380/
400

400/
415

400

440

480

500

Voltage
J7
B7 C7 D7
E7
F7
G7 FC7
L7
M7
P7
U7
Q7
V7
N7
R7
T7
S7
Code
Note: Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72. (Price Adder 9.50)

CA3KN407 • •

Table 23.85:

660/
690
Y7

Coil Voltage Codes for CA3K Control Relays (0.8–1.15 Uc)

Vdc

12

20

24

36

48

60

72

100

110

Voltage Code
JD ZD
BD
CD
ED
ND
SD
KD
FD
Note: Coil with integral suppression device available: add 3 to the code required. Example: JD3.

Table 23.86:

125

220

230

240

250

GD
LD
MD
(Price Adder 9.50)

200

MPD

MUD

UD

Coil Voltage Codes for CA4K, Low Consumption Control Relays (Wide Range Coil: 0.7–1.3 Uc)

Vdc
Voltage Code

12

24

48

72

JW3

BW3

EW3

SW3

Approvals:

File
CCN

© 2012 Schneider Electric
All Rights Reserved

RELAYS AND TIMERS

•
•

LED indicator incorporated.
Wide range coil (70 to 130% Uc), suppressor fitted as standard.

164353
NKCR

File LR43364
Class 3211 03

I12

Discount
Schedule

23-19

23

•
•

Industrial Relays

CA2K and CA3K
Refer to Catalog 8501CT0101

www.schneider-electric.us

TeSys™ K IEC Style Relays
Table 23.87:

Instantaneous Auxiliary Contact Blocks bc
Clip-on Front Mounting, 1 Block Per Control Relay
Contact Configuration

Type of Connection

Catalog Number
N.O.
2
0
1
4
3
2
1
0
2
1
0
4
3
2
1
0
2
0
1
4
3
2
1
0

LA1KN40

LA1KN20

Screw Clamp

Spring Termination

LA1KN403

LA2KT electronic time delay contact blocks

1.34

1.45

34

38

1.34

2.24

34

57

58

2.28

Faston
1 x 6.35
or 2 x 2.8

27

1.06

LA2KT

a
b
c

On panel
4xØ4

2.24
57

=

1.38
35
1.77
45

=

= = =

250 VA or 150 W

Operating temperature

–10 to + 60oC (+14o F to 140o F)
1.5 s during the time delay period,
0.5 s after the time delay.

1.97
50
58

45

Clips on front of relay

mm
59
66

in.
mm

Conforming to Standards
Approvals

Catalog No.

100

LA9D90

$ Price ea.
0.06

IEC 947, NF C 63-140, VDE 0660, BS 5424, CE
UL, CSA, DEMKO, NEMKO, SEMKO, FI

Protective treatment

Conforming to IEC 68 (DIN 50016) “TC” (Climateproof)

Degree of protection

Conforming to VDE 0106
Storage
Operation

Ambient air temperature
Maximum operating altitude

23-20

Sold in
lots of

Environment

Product
AM1DP200
AM1DE200

32.80

AB1R•g
4 maximum per Strip of 10 identical numbers, 0 to 9
25
0.70
device
Strip of 10 identical capital letters A to Z
AB1G•g
For AC and DC voltages 12 to 24 V (varistor)
LA4KE1Bd
LA4KE1Ed
Clips onto front For AC and DC voltages 32 to 48 V (varistor)
Suppressor
of relay with
For AC and DC voltages 50 to 129 V (varistor)
LA4KE1FCd
modules with locating device. For AC and DC voltages 130 to 250 V (varistor)
5
LA4KE1UG d
9.80
incorporated No tools
LED indicator required for
For DC voltages 12 to 24 V (diode + Zener diode)
LA4KC1Be
connection.
For DC voltages 32 to 48 V (diode + Zener diode)
LA4KC1Ee
For AC voltages 220 to 250 V (RC)
LA4KA1Uf
d
Protection by the limitation of the transient voltage to 2 Uc maximum. Maximum reduction of the transient voltage
peaks. Slight time delay on drop-out (1.1 to 1.5 times normal).
e
No overvoltage or oscillation frequency. Polarized component. Slight time delay on drop-out (1.1 to 1.5 times
normal).
f
Protection by limitation of the transient voltage to 3 Uc max. and limitation of the oscillation frequency. Slight time
delay on drop-out (1.2 times to twice normal).
g
See “Clip-in Marker Strips” in Catalog 8501CT0101 for information on completing the catalog number.

Table 23.91:
in.
2.22
2.60

$ Price

Clip-on
markersg

A2

1.77

Catalog No.
LA2KT2E
LA2KT2U

Accessories (supplied separately)
Description

n AM1DP200 or AM1DE200 mounting rail—35 mm DIN rail
(see page 22-16 for additional DIN rail)

C

Clip-on front mounting, 1 block per control Relay

Voltage (V)
Type
Timing Range, s
Composition C.O.
AC or DC / 24 to 48
On-delay
1 to 30
1
AC / 110 to 240
Note: For other electronic timers see Type RE7 and 9050 Type JCK, pages 23-28 and 23-30.

A1

2.05
53

2.28
58

1.77
45

2.28

0.85–1.1 Uc

Maximum switching capacity

Marker
holderg

10xØ1.3

C

240 Vac/Vdc, 2 A maximum

Table 23.90:

On printed circuit board
0.34
8.65

Electronic Time Delay Contact Blocks

Control voltage

Table 23.89:

1.97
50
=

2.28
58

RELAYS AND TIMERS

1.22
31

14.20
14.20
14.20
27.30
27.30
27.30
27.30
27.30
14.20
14.20
14.20
27.30
27.30
27.30
27.30
27.30
14.20
14.20
14.20
27.30
27.30
27.30
27.30
27.30

Relay output, with common point changeover contact

Reset time

=

23

LA1-K

LA1KN20
LA1KN02
LA1KN11
LA1KN40a
LA1KN31a
LA1KN22a
LA1KN13a
LA1KN04a
LA1KN203
LA1KN113
LA1KN023
LA1KN403a
LA1KN313a
LA1KN223a
LA1KN133a
LA1KN043a
LA1KN207
LA1KN027
LA1KN117
LA1KN407a
LA1KN317a
LA1KN227a
LA1KN137a
LA1KN047a

Not to be used on CA4KN relays.
Clip-on front mounting, 1 block per control relay.
Auxiliary contact module not suitable for safety circuits.

Table 23.88:
Approximate dimensions
for CA2, CA3, CA4K control relays

N.C.
0
2
1
0
1
2
3
4
0
1
2
0
1
2
3
4
0
2
1
0
1
2
3
4

$ Price

I12

Discount
Schedule

Without derating

Protection against direct finger contact
-58 to 176 oF (-50 to 80oC)
-13 to 122 oF (-25 to 50oC)
6562 ft (2000 m)
© 2012 Schneider Electric
All Rights Reserved

Industrial Relays

CA2SK and CA3SK
Refer to Catalog 8501CT0101

www.schneider-electric.us

TeSys™ SK IEC Style Relays
Table 23.92:
•
•
•

IEC Style Industrial Control Relays

Miniature size saves space.
Mounts on 35 mm DIN 3 track
Up to 4 poles.
Contact Configuration
Control Circuit Supply

Consumption

AC

Type of Termination

Catalog Number
N.O.

N.C.

1

1

CA2SK11 •• a

2

0

CA2SK20 •• a

1

1

CA3SK11 •• a

2

0

CA3SK20 •• a

4.2 VA
Screw clamp

DC

CA2SK11G7

a

2.2 W

$ Price

43.70
51.00

Use the appropriate voltage code to complete the catalog number (for example: CA2SK11G7)

Table 23.93:

Contact Adder Decks (for CA2SK20 only)
Contact Configuration

Type of Termination

Catalog Number
N.O.

N.C.

2

0

LA1SK20

1

1

LA1SK11

0

2

LA1SK02

Screw clamp

$ Price

16.90

Transient Suppressor Module
Dampens the voltage spike that may occur when the relay coil is de-energized. The spike may adversely affect solid
state equipment near the relay. The transient suppressor module snaps into a cavity located in the side of the relay.
These modules can be used with CA2SK and CA3SK relays.

LA1SK11

Table 23.94:

Transient Suppressor Module
Control Circuit Voltage

Catalog Number

24–48 Vac 50/60 Hz, 24–48 Vdc

LA4SKEIE

110–250 Vac 50/60 Hz, 110–250 Vdc

LA4SKEIU

Table 23.95:

21.80

Coil Voltage Codes for Control Relays

Voltage
50/60 Hz
DC
b

$ Price

12

24

36

48

72

110

120

220

230

240

380

400

480

—

B7 b

—

E7 b

—

F7

G7 b

M7 b

P7

U7 b

Q7

V7

T7 b

—

—

—

—

—

JD
BD
CD
ED
SD
—
—
—
Alternating relays CA2SKE available in these voltages only. No other voltages are available.

These alternating relays are used to alternate the use of 2 motor circuits. When the coil is energized the first time, one
contact closes and will open when the coil is de-energized. When the coil is energized again, the other contact will
close and will open when the coil is de-energized. The contacts from these alternators are to be used in the control
circuit of the starters that are controlling pump or compressor motors.
Approvals: UL File: E164353 CCN: NKCR; CSA File: LR43364 Class: 3211 03.
Table 23.96:

Alternating Relays
Coil Voltage
(Voltage-Hz)

$ Price

a

Table 23.97:

Contact Ratings for CA2SK, CA3SK, AND CA2SKE20 Relays
AC

DC

Inductive 35% PF

Approvals:

Volts

Make

Resistive 75% PF

Break

Continuous
Amperes

NEMA Rating
A
File
CCN

E164353
NKCR

A

VA

Volts

Continuous
Amperes
3

60

6

24

240

30

3

60

2

110

0.8

240

0.2

A600

600

7200

15
12

720

1.5

10

10

1.2

1.06

2.19

.20

27

56

5

.16
(4)

56

2.20

Approximate Dimensions for CA2SKE Relay
#8
or
4mm

1.93
(49)

2.28
(58)

.14
4

© 2012 Schneider Electric
All Rights Reserved

Make, Break and
Continuos Amperes

120
480

File LR43364
Class 3211 03

VA

23

CA2SKE20

Type

24–50/60
CA2SKE20••a
120.00
Use the appropriate voltage code to complete the catalog number (for example, CAZSK11G7). Only available with voltages indicated above.

RELAYS AND TIMERS

Alternating Relays, CA2SKE
Refer to Catalog 8501CT9701

Dual Dimensions:

I12

INCHES
Millimeters

Discount
Schedule

1.77
(45)

2.68
(68)

1.36
(34.5)

23-21

Industrial Relays
Square D™ NEMA Style

Type X
Class 8501 / Refer to Catalog 8501CT9601

Table 23.102: AC Contact Ratings
(for DC ratings, see page 23-23)

AC Control Relays

•
•

Straight-through wiring
Plug-in contact cartridges for easy contact conversion and
replacement
Contact conversion without removing terminal screws or wires
Self-lifting pressure wire connectors
Replaceable coil

•
•
•

Table 23.98:

AC Control Relays

Normally Open Convertible
Instantaneous Contacts

Type XMO40
Control Relay

a

Table 23.99:

Type XMO40
Master Relay
b

V

Make
NEMA
Rating A VA

120
Standard
240
or
Overlapping 480
600
Masterd

—

A600

—

—

Device
AC Relay
AC Latching Relay

Pick-Up
15
15

Drop-Out
16
13

Table 23.104: Voltage Codes

Open Typeb

Typec
2
XMO20
4
XMO40
6
XMO60
Attachments not permitted on this relay.

$ Price
204.00
336.00
457.00

AC Voltages - Hz
12–60
24–60
24–50
48–60
48–50
120–60/110–50
208–60
240–60/220–50
277–60
480–60/440–50
600–60/550–50

Code
V11
V01
V12
V18
V16
V02
V08
V03
V04
V06
V07

AC Control Relays and AC Master Relays
A

2.23
1.12 57
28

.19
5

23

Easily convertible On Delay or Off Delay
Two adjustable timing ranges
Repeat accuracy well above ±10%
Convertible 1 N.O. and 1 N.C. timed contacts
Large knob for easy adjustment of time delay
Off Delay mode times out even after loss of power.

Dual Dimensions: INCHES
Millimeters

3.50
89
3.12
79

Prov. for
(2) #8/#10 Mtg. Screws

B30080-064

Table 23.100: AC Timing Relays
RELAYS AND TIMERS

Type XO40XTE1
Timing Relay

VA

Maximum of six 8501 Type XC4 Master Cartridges may be used on
only 7 and 8 pole AC Devices

AC Timing Relays

•
•
•
•
•
•

A

Make, Break
Continuous
and
Amperes
Continuous
Amperes

60
6
30 7200 3 720
10
10
15
1.5
12
1.2
Same as standard cartridge above except
substitute 20 A for the continuous ampere rating
150 Vac, 150 mA, 8 W Maximum

A600

Logic Reed

Break

Table 23.103: Average Operating Time (ms)

AC Master Relays

Number of N.O. 20 Ampere
Convertible Contacts

Type of
Cartridge

d

20 ampere contact rating due to use of master contact
cartridges. d
Provisions for standard cartridges to be used in contact
cavities not occupied by master cartridges in 2-8 pole AC
relay.

•

Resistive
75% Power
Factor

Inductive
35% Power Factor

Control Relay a

Typec
$ Price
0
XO00
98.00
2
XO20
144.00
3
XO30
169.00
4
XO40
192.00
6
XO60
242.00
8
XO80
288.00
10
XO1000
336.00
12
XO1200
385.00
A maximum of 8 N.C. contacts is allowed on 9–12 pole relays.

AC Master Relays

•

www.schneider-electric.us

Timed
Timing Relay
N.O.
Timing
Convertible Convertible 0.2–60 s
5–180 s
Mode Instantaneous Contacts
Contacts
N.O. N.C.
Typec
Typec
0
1
1
XO00XTE1 XO00XTE2
On
2
1
1
XO20XTE1 XO20XTE2
Delay
4
1
1
XO40XTE1 XO40XTE2
0
1
1
XO00XTD1
XO00XTD2
Off
2
1
1
XO20XTD1 XO20XTD2
Delay
4
1
1
XO40XTD1 XO40XTD2

Table 23.105: Dimensions and Weight
$ Price
432.00
480.00
529.00
432.00
480.00
529.00

No. of Poles
0–4
6–8
10–12

Dim. A
in.
mm
3.95
100
5.16
131
6.36
162

Shipping Weight, lb
2.0
2.3
2.7

AC Latching Relay Dimensions

AC Latching Relays

•

Mechanical latch holds all contacts switched even after
removal of power from replaceable latching coil.
Provides sequence memory in the event of power loss. Ideal
for press control, process control and punch presses.
Replaceable unlatch coil to switch contacts back to original
state.

•
•

A

.19
5

N.O. Convertible Instantaneous
Contacts
2
3
4
6
8
c

3.50
89 Dual Dimensions: INCHES

Latching Relay
Typec
XO20XL
XO30XL
XO40XL
XO60XL
XO80XL

2.23
57

3.12
79

Table 23.101: AC Latching Relays
Type XO40XL
Latching Relay

1.12
28

Millimeters

$ Price
313.00
336.00
360.00
408.00
457.00

Table 23.106: Dimensions and Weight
No. ofPoles
2–4
6–8

Voltage Code must be specified to order these products. Refer to Table
23.104 and insert the code as shown in Table 23.107: How to Order.

Dim. A
in.
mm
6.54
166
7.74
197

Shipping Weight, lb
2.8
3.1

For replacement coils, see page 23-24.

Approvals:

Table 23.107: How to Order
File E78403
CCN NKCR

File
Class

060905
3211 03
IEC 60947-1

23-22

CP2

Discount
Schedule

•
•
•

To Order Specify:
Class Number
Type Number
Voltage Code

Catalog Number
Class

Type

8501

XO40

Voltage
Code
V02

© 2012 Schneider Electric
All Rights Reserved

Type X™ Relays

Industrial Relays
Square D™ NEMA Style

Class 8501 / Refer to Catalog 8501CT9601

www.schneider-electric.us

DC Latching Relays

•

DC Control Relays

•

Replaceable, highly reliable pure DC power plant: no
economizing resistors, overlapping contacts or dualwound coil.
Utilizes the same Type XB adder decks and
attachments as the AC version.
Offers all the features of the AC relay.
Available in up to 8 poles.
All contact poles are usable since no overlapping
contacts are needed.

•
•
•
•
Type XDO40
Control Relay

•
•
•
Type XDO40XDL
Latching Relay

Mechanical latch holds all contacts switched even
after removal of power from replaceable latching coil.
Provides sequence memory in the event of power
loss.
Ideal for sequencing applications such as press
control, process control and punch presses.
Replaceable unlatch coil to switch contacts back to
original state.

Table 23.112: DC Latching Relays
Latching Relay

Normally Open Convertible
Instantaneous Contacts

Table 23.108: DC Control Relays
Control Relay

Normally Open Convertible
Instantaneous Contacts

Type
XDO00e
XDO20e
XDO40e
XDO60e
XDO80e

0
2
4
6
8

$ Price
216.00
264.00
313.00
360.00
408.00

Type
$ Price
2
XDO20XDL e
485.00
4
XDO40XDL e
534.00
6
XDO60XDL e
582.00
8
XDO80XDL e
629.00
Note: Unlatch coil is rated for intermittent duty and should be connected through a N.O. contact
of the relay if the input signal is maintained. Order one more N.O. contact than the
application requires to use as a coil clearing contact.
A

2.23
57

.25
6

DC Control Relay Utility Auxiliary Relay

1.12
28

No. of
Poles

Table 23.109: Dimensions
A

2.23
1.12 57
28

.25
6

Dim. A

No. of Poles

in.
5.17
6.37
7.60

0–4
6–8
10–12

3.56
90 3.12
79

mm
131
162
193

3.56
90

Shipping Weight
lb.
3.1
3.4
3.8

Shipping
Weight, lb.

mm
197
228

3.9
4.2

DC Utility Relays
Ideal for utility plant applications where reliable
performance and a pure DC power plant is required. In
addition to the Type XDO relay features, the Type
XUDO provides:

•
•

DC Timing Relays

•
•
•
•
•
•

2–4
6–8

3.12
79

Dim. A
in.
7.76
8.98

Prov. for
(2) #8/#10 Mtg. Screws

B30080-159

Prov. for
(2) #8/#10 Mtg. Screws

B30080-066

Table 23.113: Dimensions

Easily convertible On Delay or Off Delay.
Two adjustable timing ranges.
Repeat accuracy well above ±10%.
Convertible 1 N.O. and 1 N.C. timed contacts.
Large knob for easy adjustment of time delay.
Off Delay mode times out even after loss of power.

Type XUDO40
Utility Relay

•

Up to 12 poles N.O. or N.C.
Nominal 125 Vdc coil, capable of handling 140 Vdc
continuously and picking up at 105 Vdc after having
been operated at 140 Vdc continuously. Other voltages
with comparable operating characteristics are
available.
Enclosed device capable of operating in 145°F
ambient.

Number of Convertible Contacts
N.O.
4
0
8
0
12
0

Table 23.110: DC Timing Relays

0
2
4
0
2
4

On
Delay
Off
Delay
7.77
197

Timed
Convertible
Contacts
N.O.
1
1
1
1
1
1

Timing Relay

N.C.
1
1
1
1
1
1
.25
6

0.2–60 s

5–180 s

Type
XDO00XTE1 e
XDO20XTE1 e
XDO40XTE1 e
XDO00XTD1 e
XDO20XTD1 e
XDO40XTD1 e

Type
XDO00XTE2 e
XDO20XTE2 e
XDO40XTE2 e
XDO00XTD2 e
XDO20XTD2 e
XDO40XTD2 e

$ Price
522.00
601.00
648.00
522.00
601.00
648.00

Device
DC Relay
DC Latching Relay

DC Voltages for
8501 XUDO Relays ONLY
6
12
24
48
125
250

Pick-Up
37
37

Inductive

Resistive

Make and Break Continuous Make and Continuous
Amperes
Break
Amperes
Amperes
138 VA Max.
Amperes
125
1.1
5
4
5
Standard
P600
250
0.55
5
0.8
5
Overlapping
125
P150
1.1
5
4
5
Logic Reed
—
—
30 Vdc, 60 ma
Note: Do not use any 8501 Type XC4 Master Cartridges on any DC-operated device.
NEMA
Rating

© 2012 Schneider Electric
All Rights Reserved

CP2

510.00
629.00

Drop-Out
21
45

DC Voltages for
8501 XDO Relays
6
12
24
32
48
72
90
115/125
230/250

Code
V50
V51
V53
V56
V63
V67

Prov. for
(2) #8/#10 Mtg. Screws

e

Code
V50
V51
V53
V54
V56
V58
V59
V62
V66

Voltage code must be specified to order these products. Refer to Table 23.116 and insert
the appropriate code as shown in Table 23.117: How to Order.

DC Ratings

Volts

390.00

Table 23.116: Voltage Codes—8501 XUDO and XDO Relays

2.23
1.12 57
28

Table 23.111: DC Contact Ratings (for AC ratings, see page 23-22)
Type of
Cartridge

$ Price

Table 23.115: Average Operating Times (in ms)

3.56
903.12
79

B30080-075 A

Type
XUDO40 e
XUDO04 e
XUDO80 e
XUDO08 e
XUDO1200 e
XUDO0012 e

23

Normally
Open Convertible
Instantaneous
Contacts

Timing
Mode

Open Type

N.C.
0
4
0
8
0
12

Table 23.117: How to Order
•
•
•

To Order Specify:
Class Number
Type Number
Voltage Code

Catalog Number
Class

Type

Voltage Code

8501

XDO40

V53

For Replacement coils, see page 23-24
For UL and CSA approvals, see page 23-22

Discount
Schedule

RELAYS AND TIMERS

Table 23.114: DC Utility Relays
Type XDO40XTE2
Timing Relay

23-23

Industrial Relays
Square D™ NEMA Style

Type X™ Relays
Class 8501 / Refer to Catalog 8501CT9601
www.schneider-electric.us

Table 23.118: Type X™ Relays
Description
Mechanical Latch Attachment—Mounts on any 2 through 8-pole relay (except XMO master relay). The Type XL and XDL latch
attachments are identical in size and mounting provisions. The Type XLAC latch attachment has a continuous-duty-rated coil which is
replaceable. The Type XDLDC latch attachment has an intermittent–rated coil (replaceable) and should be connected
through a N.O. contact of the basic relay if the input signal is maintained to the unlatch coil.
AC Latch Attachment
DC Latch Attachment
Pneumatic Timer Attachment—Mounts only on any 0 through 4-pole AC or DC relays (except XMO master relay). It provides 1
N.O. and 1 N.C. convertible timed contacts, which are the same Type XC1 cartridges used on the basic relay. Two timing ranges are
available, and conversion from On Delay to Off Delay or vice versa is easy.
Off Delay
0.2–60 seconds
5–180 seconds
On Delay
0.2–60 seconds
5–180 seconds

Type

Timer Lockout Cover—Fits over the time delay adjustment knob of any Type XT timing attachment. The Lockout Cover is designed
to protect the time setting against accidental adjustment. It mounts directly to the timing attachment with two included screws.

$ Price

XLa
XDLa

169.00
222.00

XTD1
XTD2

336.00
336.00

XTE1
XTE2

336.00
336.00

XJ1

9.00

XB20
XB40

48.00
98.00

XC1

24.20

XC2

24.20

Adder Decks—Adder decks are used to expand the number of poles on a relay. The basic 4-pole relay can be easily converted to an
8-pole or 12-pole relay by installing one or two adder decks. The Class 8501 Type XB20 comes with 2 convertible contact cartridges
and will accept 2 additional convertible contact cartridges. The Class 8501 Type XB40 comes with 4 convertible contact cartridges.
The same Type XB adder deck is used for both the middle and upper decks of the AC or DC relay.
With 2 N.O. contact cartridges
With 4 N.O. contact cartridges

Contact Cartridges—The Type X relay offers 4 Types of contact cartridges. All are color–coded for visual identification of each Type.
Standard Cartridge—The standard cartridge, used for most applications, has a black case.
Overlapping Cartridge—Same NEMA Type A600 AC rating as standard cartridge and a NEMA Type P150 DC rating. When it is
used in the N.O. mode it will close early and when used in the N.C. mode it will open late. If two or more are used together, the N.O.
contacts will close before the N.C. contacts open as the relay picks up. Overlap also occurs during dropout. Overlapping cartridge
has a red case.
May be ordered factory installed:
• Substitute 1 N.O. and 1 N.C. overlapping cartridges for 2 standard cartridges.
• Substitute 2 N.O. and 2 N.C. overlapping cartridges for 4 standard cartridges.
• Substitute 3 N.O. and 3 N.C. overlapping cartridges for 6 standard cartridges.
• Substitute 4 N.O. and 4 N.C. overlapping cartridges for 8 standard cartridges.
Master Cartridge—Features the same contact ratings as the Type XC1 standard cartridge except it has a 20 ampere continuous
current rating instead of 10 amperes. It can be used in circuits where a master relay is required. Master cartridge has a blue case.
Maximum of 6 master cartridges may be used on any 7 and 8-pole AC relays. Do not use any master cartridges on 9-12-pole
AC or any DC-operated devices. Note: If master cartridges are added to a standard relay, attachments (latch mechanism,
timers, etc.) cannot be used.
Logic Reed Cartridge—See logic reed adder deck above.

Form
Y1591
Y1592
Y1593
Y1594

Add 24.20
Add 24.20
Add 24.20
Add 24.20

23
RELAYS AND TIMERS

XC4

60.00

Mounting Track—The mounting track has pre-punched mounting holes to simplify mounting the track on the control panel. The relay
mounting screws are factory installed on the track so that the relays can be hung prior to tightening the screws.
9 in. long for 4 relays
18 in. long for 8 relays
27 in. long for 12 relays
36 in. long for 16 relays

XM4
XM8
XM12
XM16

19.70
29.80
36.40
42.90

Manual Test Tool—Provides a means of manually switching the contacts of a basic relay or timing relay and holding all contacts in
their switched state until the tool is removed. This simplifies the checking of control circuits without power on the coil or contacts.

XA1

6.10

Transient Suppressor—Consists of an R-C circuit designed to suppress coil generated transients to approximately 200 percent of
peak voltage. It is particularly useful when switching the Type X relay near solid state equipment. It is designed for use on coils up to
120 Vac.

XS1

48.00

NEMA 1 Enclosure—Formed from sheet steel to provide strength and rigidity. Two conduit knockouts are located in both the top and Class 9991
bottom of the enclosure. The enclosure is furnished with self tapping screws for mounting the relay inside the enclosure.
Type
Accommodates a single 4 or 8-pole AC or DC relay, 12-pole AC relay, 4-pole AC latching relay, and 4-pole AC timing relay.
UE7
Note: The 4-pole DC latching relay, 4-pole DC timing relay, 8-pole AC and DC latching relays and 12-pole utility auxiliary relay will not fit.
a

29.60

See Mechanical Latch Attachment Voltage Codes table below:

Table 23.119: Mechanical Latch Attachment Voltage Codes
AC Voltage
24–60
24–50
120–60/110–50
208–60
240–60/220–50
277–60
480–60/440–50
600–60/550–50

Code
V01
V12
V02
V08
V03
V04
V06
V07

DC Voltage
6
12
18
24
48
72
90
115/125
230/250

Table 23.120: How to Order

Code
V50
V51
V99
V53
V56
V58
V59
V62
V66

•
•
•
•

To Order Specify:
Class Number
Type Number
Voltage Code for mechanical latch attachment
Form for factory installed overlapping contacts

Catalog Number
Class

Type

8501

XTE1

Table 23.121: Relay Coil Selection and Pricing
Device
Type

DC

Device
Type

Equipment To Be Serviced
Class
8501

Type
XD
XDL
XUD

Equipment To Be Serviced

Coil Prefix,
or Class
and Type

Hz

9998 XD
9998 XDL
9998 XUD

—
—
—

SUFFIX
(The complete coil number consists of prefix or the Class and Type, followed by suffix.)
6V
19
19
19

12 V
28
28
28

18 V
34
34B
—

24 V
37
37B
37

32 V
40
40B
—

48 V
46
46B
46

64 V
49
49B
—

72 V
52
52B
—

90 V
55
55B
—

Coil
Burden
Watts
110 V 115/125 V 220 V 230/250 V
—
58
—
67
18
—
58B
—
67B
50
—
58d
—
67c
16
Coil Volt-Amperes

Coil Prefix
or Class
and Type

Class
Type
—
24 V 110-115
120 V 208 V 220 V 240 V 277 V 380 V 440 V 480 V 550 V 600 V In-rush
Sealed
V
60
23
—
44
51
52
53
55
—
—
62
—
65
148
23
XO,
AC
8501
9998 X b
XMO
50
24
44
—
52
53
—
—
—
62
—
65
—
143
25
b
To order an unlatch coil add the letter “L” to the type number and the letter “B” to the suffix number. Example: for a 120 V 60 Hz unlatch coil order a Class 9998 Type XL44B.
c
Not dual rated—250 Vdc only
d
125 Vdc only

23-24

CP2

Discount
Schedule

$ Price
168.00
216.00
168.00
$ Price

69.00

© 2012 Schneider Electric
All Rights Reserved

Solid State Relays

Type SSR
Refer to Catalog DIA3ED2090304EN-US

www.schneider-electric.us

Schneider Electric Solid State Relays
Solid state relays do not have any moving parts to wear out. Combined with vibration resistance, arc-less switching and
the lack of acoustical noise, you have the ideal product for switching applications that demand reliable execution. For
added reliability the Zelio™ SSRP and SSRD solid state relays utilize Direct Copper Bonding (DCB) technology to
decrease internal temperatures and improve the overall quality of the product.
Key features include:
SSRPCDS25A1

•
•
•
•
•
•
•
•
•

Input voltage range 3 to 32 Vdc, 90 to 280 Vac
Breaking capacities up to 125 A
Zero voltage turn on, low EMI / RFI
No moving parts
Shock and Vibration resistant
No acoustical noise
Fast response
Arc-less switching
Long life (>109 operations)

Table 23.122: Solid State Relays
Voltage Range
Switching

Input

Output

Load Current
Range

V

V

A

3•••32 DC

24•••280 AC

Catalog
Number

$ Price ea.

Panel Mounted

48•••530 AC

SSRDCDS10A1
4•••32 DC

48•••660 AC

SCR Output
Zero voltage switching

24•••280 AC
90•••280 AC

48•••530 AC
48•••660 AC

MOSFET Output
Instant switching

3.5•••32 DC

0•••100 DC

4•••32 DC

24•••280 AC

3•••32 DC

24•••280 AC

90•••280 AC

24•••280 AC

90•••140 AC

24•••280 AC

10
25
50
75
90
125
10
25
50
75
90
125
12
25
40

SSRPCDS10A1
SSRPCDS25A1
SSRPCDS50A1
SSRPCDS75A2
SSRPCDS90A3
SSRPCDS125A3
SSRPP8S10A1
SSRPP8S25A1
SSRPP8S50A1
SSRPP8S75A2
SSRPP8S90A3
SSRPP8S125A3
SSRPCDM12D5
SSRPCDM25D5
SSRPCDM40D5

40.60
41.90
59.00
100.00
114.00
144.00
43.10
45.70
53.00
114.00
117.00
134.00
66.00
82.00
114.00

10
20
30
45
10
20
30
45

SSRDCDS10A1
SSRDCDS20A1
SSRDCDS30A1
SSRDCDS45A1
SSRDP8S10A1
SSRDP8S20A1
SSRDP8S30A1
SSRDF8S45A1

58.00
81.00
85.00
100.00
61.00
70.00
78.00
106.00

SCR Output
Zero voltage switching

SSRDCDS45A1

Table 23.123: Accessories For Panel Mount Solid State Relays
Description
Heat Sink
Pre-Cut Thermal Transfer Pad
(sold in pack sof 10)

For Use With Relays
SSRPP8S••• •
SSRPCDS••• •
SSRPP8S••• •
SSRPCDS••• •

Load Current Range

Catalog Number

up to 50 A

SSRAH1

$ Price ea.
26.00

up to 125 A

SSRAT1

2.30

RELAYS AND TIMERS

DIN Rail Mounted

23

SSRAH1

SSRAT1

© 2012 Schneider Electric
All Rights Reserved

CP2

Discount
Schedule

23-25

Timers

RE11/RE48/REXL
Refer to Catalog 9050CT0001

www.schneider-electric.us

Zelio ™ IEC Style—17.9 mm wide
Table 23.124: RE11 Modular Timers—17.9 mm wide (Multi-range timers offering 7 selectable ranges)
Output 1 C/O contact

RE11RLMU

Functions
Supply Voltages
Rated Current
Catalog Number
$ Price
On delay
24 Vdc, 24–240 Vac
8A
RE11RAMU
42.90
Interval
24 Vdc, 24–240 Vac
8A
RE11RHMU
42.90
Asymmetrical repeat cycle
24 Vdc, 24–240 Vac
8A
RE11RLMU
53.00
Asymmetrical repeat cycle
12 Vac/Vdc
8A
RE11RLJU
75.00
One shot
24 Vdc, 24–240 Vac
8A
RE11RBMU
52.00
Off delay with control start
24 Vdc, 24–240 Vac
8A
RE11RCMU
52.00
Multi-function a
24 Vdc, 24–240 Vac
8A
RE11RMMU
62.00
Multi-function a
12–240 Vac/Vdc
8A
RE11RMMW
75.00
Multi-function a
12–240 Vac/Vdc
8A
RE11RMMWS
75.00
Multi-function a
12 Vac/Vdc
8A
RE11RMJU
75.00
Multi-function b
24 Vdc, 24–240 Vac
8A
RE11RMEMU
75.00
Multi-function a
24 Vdc, 24–240 Vac
8A
RE11RMXMU
75.00
a
Timing ranges: 0.1–1 s, 1–10 s, 0.1–10 min, 1–10 min, 0.1–1 hr, 1–10 hr, 10–100 hr
b
Timing ranges: 0.1–1 s, 1–10 s, 0.1–10 min, 1–10 min, 0.1–1 hr, 1–10 hr
IEC 61812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC (CE marking) +
Conforming to standards
EMC directive (89/336/EEC + IEC 60669-2-3)
cULus
File: E173076 CNN: NRNT
File: E173076 CNN: NRNT7
Approvals
CSA
File: 217698 Class 3211 07
CE
GL except RE11 RMX MU and RE11 RME MU
o
o
F ( C) –22 to +140 (–30 to +60)
Ambient air temperature around the Storage
o
o
device
Operation F ( C) –4 to +140 (–20 to +60)

Table 23.125: RE11 Modular Timers—17.9 mm wide (Multi-function, dual function or single function)
Functions

RE11LHBM

Supply Voltages

Rated Current

Catalog Number

0.7A
0.7A
0.7A
0.7A
0.7A

RE11LAMW
RE11LHBM
RE11LCBM
RE11LLBM
RE11LMBM

Solid state output
On delay
24–240 Vac/Vdc
Interval
24–240 Vac
Off delay with control contact
24–240 Vac
Asymmetrical repeat cycle
24–240 Vac
Multi-function
24–240 Vac
Timing ranges: 0.1–1 s, 1–10 s, 0.1–10 min, 1–10 min, 0.1–1 hr, 1–10 hr, 10–100 hr

45.40
42.90
52.00
75.00
62.00

IEC 61812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC (CE marking) +
EMC directive (89/336/EEC + IEC 60669-2-3)

Conforming to standards

cULus

File: E173076 CNN: NRNT
File: E173076 CNN: NRNT7
File: 217698 Class: 3211 07

23

Approvals

Ambient air temperature around the
device

$ Price

CSA
CE
Storage oF (oC) –22 to 140 (–30 to +60
Operation oF (oC) –4 to 140 (–20 to +60)

RELAYS AND TIMERS

Table 23.126: RE48 Panel Mount Timers (For required socket, refer to the catalog section)
Functions

Supply Voltages

Rated Current

Catalog Number

$ Price

Single function: on delay, two relay outputs
Repeat cycle: two relay outputs
Multi-function: on delay, one shot, off delay, repeat cycle
Multi-function: on delay and interval, two relay outputs,
of which one selectable and instantaneous

24–240 Vac/Vdc
24–240 Vac/Vdc
24–240 Vac/Vdc

2x5A
2x5A
2x5A

RE48ATM12MW
RE48ACV12MW
RE48AML12MW

73.00
88.00
86.00

24–240 Vac/Vdc

2 x 5A

RE48AMH13MW

86.00

IEC 61812-1, EN 50081-1/2, EM 50082-1/2, LV directives (73/23/EEC +
93/68/EEC (CE marking) + ENC directive (89/336/EEC + IEC 60669-2-3)

Conforming to standards

File: E173076 CNN: NRNT2
File: E173076 CNN: NRNT8
File: 217698 Class: 3211 070

cURus

RE48A TM12MW
Approvals

CSA
CE, C-Tick, GL
RoHS compliant as of date code 0625
o
o
F ( C) –40 to 158 (–40 to +70)
Storage
o
o
Operation F ( C) –4 to 122 (–20 to +50)

Ambient air temperature around the device

Table 23.127: REXL Miniature Plug-in Timers (For required socket, refer to the catalog section)
4 pole

REXL2TMJD

Approvals:

23-26

2 pole

Rated
Rated
Function
Supply Voltages Current
Catalog Number $ Price Current
12 Vdc
3A
REXL4TMJD
56.00
5A
24 Vdc c
3A
REXL4TMBD
56.00
5A
Single function (On-Delay 24 Vac 50/60 Hz c
3A
REXL4TMB7
56.00
5A
120 Vac 50/60 Hz
3A
REXL4TMF7
56.00
5A
230 Vac 50/60 Hz
3A
REXL4TMP7
56.00
5A
Timing Ranges
0.1–1 s, 1–10 s, 0.1–1 min, 1–10 min, 0.1–1 hr, 1–10 hr, 10–100 hr
For 48 Vac supply, additional resistor 390 ohm 4 W / 24 V
c
For 48 Vac supply, additional resistor 560 ohm 2 W / 24 V

File
CCN

E173076
NRNT2

File
CCN

E173076
NRNT8

CP2

Discount
Schedule

File
Class

Catalog Number
REXL2TMJD
REXL2TMBD
REXL2TMB7
REXL2TMF7
REXL2TMP7

217698
321107

$ Price
53.00
53.00
53.00
53.00
53.00

IEC 61812-1

RoHS
as of date
Compliant code 0625

© 2012 Schneider Electric
All Rights Reserved

Timers

RE7
Refer to Catalog 9050CT0001

www.schneider-electric.us

Zelio ™ IEC Style—22.5 mm
These timers offer multi range timing from 0.05 to 300 hours, in 10 timing ranges.
Table 23.128: RE7M 6 Function and 8 Function Timers
Function

Supply Voltages

6 Function Timer
On-Delay Timer
Off-Delay Timer
Interval Timer
• start on energization
• start on opening of remote control contact

RE7ML

Repeat Cycle Timer with start during the OFF period.
Repeat Cycle Timer with start during the ON period
External control possible for:
• start of time delay
• partial stop of time delay
• adjustment of time delay
8 Function Timer

Relay Output

Catalog Number

$ Price

1 C/O, SPDT

24 Vdc or Vac
42–48 Vdc or Vac
110–240 Vac

RE7ML11BU

226.00

RE7MY13BU

252.00

RE7MY13MW

277.00

2 C/O, DPDT
24 Vdc or Vac
110–240 Vac

Same as 6 Function Timer a plus
Timer for star-delta starting
• with double On-Delay timing
• with changeover contact to star connection

2 C/O, DPDT
24–240 Vdc or Vac

a

Except control of partial stop of time delay for RE7MY13BU.

Table 23.129: RE7T On-Delay Timers
Functions

Supply Voltages

On-Delay Timer

24 Vdc or Vac
110–240 Vac

On-Delay Timer
External control possible for:
start of time delay
partial stop of time delay
adjustment of time delay b

24 Vdc or Vac
42–48 Vdc or Vac
110-240 Vac

On-Delay Timer
Remote control possible for:
adjustment of time delay b

24 Vdc or Vac
42–48 Vdc or Vac
110–240 Vac

•
•
•

Relay Output
1 C/O, SPDT

Catalog Number

$ Price

RE7TL11BU

138.00

RE7TM11BU

177.00

RE7TP13BU

189.00

1 C/O, SPDT

2 C/Oc, DPDT

RE7T

Table 23.130: RE7M Symmetrical and Asymmetrical Timers
Supply Voltages

Relay Output

Catalog Number

$ Price

RE7MA11BU

194.00

RE7MA13BU

208.00

2 C/O c, DPDT
24 Vdc or Vac
42–48 Vdc or Vac
110–240 Vac

On-Delay and Off-Delay Timer
Start control via external contact only

RE7M

Asymmetrical Timers: On and Off delay times are adjusted separately.
On-Delay and Off-Delay Timer
1 C/O, SPDT
External control possible for:
24 Vdc or Vac
• partial stop of time delay
42–48 Vdc or Vac
RE7MV11BU
214.00
• adjustment of time delay b
110–240 Vac
Start control via external contact only
b
By external potentiometer, to be ordered separately (see page 3 of Catalog 9050CT0001 for specifications). If external potentiometer is used, the internal
potentiometer is automatically disconnected.
c
A switch on the front face of the timer allows the second contact to be used in instantaneous mode.

Table 23.131: Output Circuit Specifications for RE7

Table 23.132: Output Circuit Specifications for RE8
Maximum Switching Voltage

250 Vac/Vdc

Current Limit, Ith

8A

Rated Operational Limits at 70oC

24 V

115 V

250 V

AC-15 N.C. contact
Conforming to
IEC60947-5-1/1991 and AC-15 N.O. contact
VDE 060
DC-13 N.O. contact

3A

3A

3A

Rated Operational Limits at 150oF (70oC)

5A

5A

5A

2A

0.2 A

0.1A

Conforming to IEC 60947-51/1991 and VDE 0660

UL and CSA Current
NEMA / UL B300

Resistive Rating
Inductive Rating

Current Limit Ith

8A
24 V

115 V

AC-15

3A

3A

3A

DC-13

2A

0.2 A

0.1 A

UL and CSA Current Ratings (Resistive)

5A
3600 VA Make, 360 VA Break,
5 A Carry

NEMA / UL B300 Ratings (Inductive)

250 V

5A
3600 VA Make, 360 VA Break.
5 A Carry

RE7, RE8, and RE9 Timers comply to the following:
Conforming to Standards

IEC 61812-1, EN 61812-1
File E164353
NKCR

Product Approvals

CE Marking
Ambient Air Temperature

© 2012 Schneider Electric
All Rights Reserved

File 089150
Class 3211-07

IEC 61812-1

RE7, RE8, and RE9 Timers conform to European regulations relating to CE Marking
Storage

-40oF to +185oF (-40oC to +85oC)

Operation

-4oF to +140oF (-20oC to +60oC)

CP2

Discount
Schedule

23-27

RELAYS AND TIMERS

1 C/O, SPDT

23

Functions

Symmetrical Timers: On and Off delay times are equal.
On-Delay and Off-Delay Timer
External control possible for:
24 Vdc or Vac
• partial stop of time delay
42–48 Vdc or Vac
• adjustment of time delay b
110–240 Vac
Start control via external contact only

Timers

RE7
Refer to Catalog 9050CT0001

www.schneider-electric.us

Zelio ™ IEC Style—22.5 mm
Table 23.133: RE7R Timers Off-Delay Timers
Functions

Supply Voltages

Relay Output

Catalog Number

$ Price

On De-energization, Adjustable from 0.05 s to 10 min, in 7 Ranges
1 C/O
Off-Delay Timer
(Times without power)

24–240 Vdc or Vac

RE7RB11MWa

189.00

RE7RB13MWa

214.00

RE7RA11BU

164.00

RE7RM11BU

177.00

RE7RL13BU

189.00

SPDT
2 C/O
Off-Delay Timer
Remote control possible for:
• adjustment of time delayb

24–240 Vdc or Vac
DPDT

On Opening of External Control Contact, Adjustable from 0.05 s to 300 h, in 10 Ranges

RE7R

1 C/O

Off-Delay Timer
External control possible for:
• partial stop of time delay
• adjustment of time delay b

24 Vdc or Vac
42–48 Vdc or Vac
110–240 Vac

SPDT
On opening of Low Level External Control Contact, Adjustable from 0.05 s to 300 h, in 10 Ranges
1 C/O
Off-Delay Timer
24 Vdc or Vac
External control possible for:
42–48 Vdc or Vac
• partial stop of time delay
110–240 Vac
• adjustment of time delay b
SPDT
2 C/Oc, DPDT
24 Vdc or Vac
Off-Delay Timer
42–48 Vdc or Vac
110–240 Vac

a
If the device has been stored de-energized for more than a month, it must be energized for about 15 seconds to activate it.
Subsequently, a time of > 1 s is enough to activate the time delay.
Note: If this time is not complied with, the relay will remain energized indefinitely.

Table 23.134: RE7P Interval Timers
Functions

Supply Voltages

Relay Output

Catalog Number

$ Price

Start on Energization
1 C/O
24 Vdc or Vac
110–240 Vac

Interval Timer

RE7P

151.00

RE7PP13BU

189.00

RE7PM11BU

151.00

RE7PD13BU

189.00

SPDT
2 C/O c
Interval Timer
External control possible for:
• adjustment of time delay b

23

RE7PE11BU

24 Vdc or Vac
42–48 Vdc or Vac
110–240 Vac
DPDT

Start on Opening of External Control Contact
1 C/O

RELAYS AND TIMERS

Interval Timer
External control possible for:
• partial stop of time delay
• adjustment of time delay b

24 Vdc or Vac
42–48 Vdc or Vac
110–240 Vac

Interval Timer

24 Vdc or Vac
42–48 Vdc or Vac
110–240 Vac

SPDT
2 C/O c

DPDT

Table 23.135: RE7C Timers Symmetrical and Asymmetrical Relays
Functions

Supply Voltages

Relay Output

Catalog Number

$ Price

Symmetrical Relays with Start during Off Period
1 C/O
24 Vdc or Vac
110–240 Vac

Repeat Cycle Timer

RE7CL11BU

164.00

RE7CP13BU

202.00

SPDT
2 C/O c
Repeat Cycle Timer
External control possible for:
• adjustment of time delay b

24 Vdc or Vac
42–48 Vdc or Vac
110–240 Vac
DPDT

RE7C

Asymmetrical, with Separate Adjustment of On-Delay and Off-Delay
Repeat Cycle Timer
1 C/O
External control possible for:
24 Vdc or Vac
42–48 Vdc or Vac
RE7CV11BU
214.00
• start period
110–240 Vac
• adjustment of time delays b
SPDT
• partial stop
b
By external potentiometer, to be ordered separately (see page 3 of Catalog 9050CT0001 for specifications). If external potentiometer is used, the internal
potentiometer is automatically disconnected.
c
A switch on the front face of the timer allows the second contact to be used in instantaneous mode.

For conformance to standards, see page 23-32

RoHS Compliant as of date code 0626

23-28

CP2

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Timers

RE8/RE9
Refer to Catalog 9050CT0001

www.schneider-electric.us

Zelio™ IEC Style—22.5 mm
Table 23.136: On-Delay (timing starts on energization), TDE
Relay Output

Timing Range a
0.1–3 s
0.1–10 s
0.3–30 s
3–300 s
20 s–30 min

Supply Voltages

1 C/O
24 Vdc or Vac
110–240 Vac
SPDT

Catalog Number
RE8TA61BUTQ
RE8TA11BUTQ d
RE8TA31BUTQ d
RE8TA21BUTQ d
RE8TA41BUTQ

Standard Pack Quantity b
10
10
10
10
10

$ Price
75.00
75.00
75.00
75.00
75.00

Table 23.137: Off-Delay (timing starts on de-energization), TDD
Control Contact
1 C/O

24 Vdc or Vac

SPDT

110–240 Vac

RE8TA
Self-Powered (Times without power)
1 C/O
24 Vdc or Vac
110–240 Vac

d

0.1–10 s
0.3–30 s
3–300 s
0.1–10 s
0.3–30 s
3–300 s
20 s–30 min

RE8RA11BTQ d
RE8RA31BTQ
RE8RA21BTQ d
RE8RA11FUTQ d
RE8RA31FUTQ
RE8RA21FUTQ d
RE8RA41FUTQ

10
10
10
10
10
10
10

95.00
95.00
95.00
95.00
95.00
95.00
95.00

0.05–0.5 s
0.1–10 s

RE8RB51BUTQ
RE8RB11BUTQ

10
10

105.00
105.00

10

105.00

0.3–30 s
RE8RB31BUTQ
SPDT
Also available in pack of one; delete TQ from the end of the catalog number. Example: RE8TA11BU.

Table 23.138: Repeat Cycle Timer
Relay Output
1 C/O

Supply Voltages

Timing Range a

Catalog Number

Standard Pack Quantity b

24 Vdc or Vac
110–240 Vac

0.1–10 s

RE8CL11BUTQ

10

105.00

0.1–10 s
0.3–30 s

RE8PE11BUTQ
RE8PE31BUTQ

10
10

87.00
87.00

3–300 s

RE8PE21BUTQ

10

87.00

0.1–10 s
0.3–30 s
3–300 s
0.1–10 s
0.3–30 s
3–300 s

RE8PD11BTQ
RE8PD31BTQ
RE8PD21BTQ
RE8PD11FUTQ
RE8PD31FUTQ
RE8PD21FUTQ

10
10
10
10
10
10

101.00
101.00
101.00
101.00
101.00
101.00

0.05–1 s

RE8PT01BUTQ

10

107.00

$ Price

SPDT

On Energization
1 C/O
24 Vdc or Vac
110–240 Vac
SPDT
By Control Contact
1 C/O

24 Vdc or Vac

SPDT

110–240 Vac

On De-Energization
1 C/O
24 Vdc or Vac
110–240 Vac

RE8PE

a
b

SPDT
For easier adjustment, it is preferable to set the time delay between the maximum value in the range and one tenth of this value. Example: RE8TA11BUTQ
timing range 0.1–10 s, recommended use 1–10 s.
Orders must specify standard pack quantity or multiples of that quantity.

For technical information, refer to . . . . . . . . . . . . . . . . . . . . . . . . page 23-32.

RELAYS AND TIMERS

Table 23.139: Interval Timer

Table 23.140: On-Delay Timer (Solid State Output)

24–240 Vac or Vdc

Function

On-Delay

Timing Range c
0.1–10 s
0.3–30 s
3–300 s
40 s–60 min

Catalog Number
RE9TA11MW
RE9TA31MW
RE9TA21MW
RE9TA51MW

$ Price

23

Power Supply Circuit

87.00
87.00
87.00
87.00

Table 23.141: Off-Delay Timer (Solid State Output)
0.1–10 s
RE9RA11MW7
126.00
0.3–30 s
RE9RA31MW7
126.00
3–300 s
RE9RA21MW7
126.00
40 s–60 min
RE9RA51MW7
126.00
For easier adjustment, it is preferable to set the time delay between the maximum value in the range and one tenth of this value. Example: RE9TA11MW
timing range 0.1-10 s, recommended use 1-10 s.

24–240 Vac
c

Off-Delay

RoHS Compliant as of date code 0626
RE9TA

For technical information, refer to catalog 9050CT0001.

© 2012 Schneider Electric
All Rights Reserved

CP2

Discount
Schedule

23-29

Timers

Type JCK
Class 9050 / Refer to Catalog 9050CT9601
www.schneider-electric.us

Square D™ General Purpose Plug-In
•
•
•
•
•
•
•
•
•
•

9050JCK timing relays are designed to provide low-cost timing
in a plug-in housing. The Types JCK11 thru 59 provide ±1%
repeat accuracy. The Types JCK60 and 70 offer ±0.1% repeat
accuracy. These timers are directly interchangeable with many
other 8 and 11 pin tube base timers.

Up to ±0.1% repeat accuracy
Timing from 0.05 seconds to 999 hours
Available in 5 timing modes
DPDT contacts (2 N.O. and 2 N.C.)
10 A contact rating
Transient protected
Hold down spring available
Variable or fixed time delay
Horsepower rated
RoHS compliant

9050JCK46V20

Table 23.142: Variable Time Delay
Off
Delayb

$ Price

Off Delay
Power Trigger

0.1–10 seconds
JCK11f
78.00 JCK21f
98.00
JCK21PTf
0.3–30 seconds
JCK12f
78.00 JCK22f
98.00
JCK22PTf
0.6–60 seconds
JCK13f
78.00 JCK23f
98.00
JCK23PTf
1.2–120 seconds
JCK14f
78.00 JCK24f
98.00
JCK24PTf
1.8–180 seconds
JCK15f
78.00 JCK25f
98.00
JCK25PTf
0.1–10 minutes
JCK16f
87.00 JCK26f
107.00
JCK26PTf
0.3–30 minutes
JCK17f
87.00 JCK27f
107.00
JCK27PTf
0.6–60 minutes
JCK18f
87.00 JCK28f
107.00
JCK28PTf
1.2–120 minutes
JCK19f
87.00 JCK29f
107.00
JCK29PTf
a
Two dials are provided for independently adjustable repeat cycle timing ranges.
b
Initiating contact can be up to 50 feet from the timer.

$ Price

Interval

$ Price

98.00
98.00
98.00
98.00
98.00
107.00
107.00
107.00
107.00

JCK31f
JCK32f
JCK33f
JCK34f
JCK35f
JCK36f
JCK37f
JCK38f
JCK39f

78.00
78.00
78.00
78.00
78.00
87.00
87.00
87.00
87.00

98.00
98.00
98.00
98.00
98.00
107.00
107.00
107.00
107.00

$ Price

JCK51f
JCK52f
JCK53f
JCK54f
JCK55f
JCK56f
JCK57f
JCK58f
JCK59f

140.00
140.00
140.00
140.00
140.00
147.00
98.00
98.00
98.00

AC
Volts

120
240

30
15

3
1.5

10
10

10
10

Inductive
hp

DC
Volts

1/3
1/2

28

3

3

10

23

AC15 / B300 (NO/NC)
DC13 / R300 (NO)
Type JCK60

RELAYS AND TIMERS

This On Delay timer uses a 5 position rotary switch to select the timing
range. The three pushbutton thumbwheels are used to select the time
value.
Table 23.146: Selection and Pricing
Timing
Modes

Timing Ranges

.01s
0.1s
S
On Delay 0.1m
M
0.1h
H

Class 8501 Sockets
For sockets, see page 23-14
For DIN rail, see page 24-16

For all 9050JCK timers:

DC Amperes

Inductive 35% P.F.

Res. Make Break
and Continuous

AC Amperes

$ Price

JCK1F(XXXX)cf

Type

0.05–9.99 seconds
00.1–99.9 seconds
001–999 seconds
00.1–99.9 minutes
001–999 minutes
00.1–99.9 hours
001–999 hours

$ Price

JCK60f 152.00

Type JCK70

With appropriate 8501NR Socket:
File
CCN

JCK41PTf
JCK42PTf
JCK43PTf
JCK44PTf
JCK45PTf
JCK46PTf
JCK47PTf
JCK48PTf
JCK49PTf

Table 23.145: Contact Ratings
Timing Range (seconds)

0.1 to 180
78.00
181 to 3600
87.00
0.1 to 180
98.00
Off Delay e
JCK2F(XXXX)cf
181 to 3600
107.00
0.1 to 180
98.00
Off Delay with
JCK2F(XXXX)PTcf
Power Trigger
181 to 3600
107.00
0.1 to 180
78.00
Interval
JCK3F(XXXX)cf
181 to 3600
87.00
0.1 to 180
98.00
One Shote
JCK4F(XXXX)cf
181 to 3600
107.00
0.1 to 180
98.00
One Shot with
JCK4F(XXXX)PTcf
Power Trigger
181 to 3600
107.00
0.1 to 180
140.00
Repeat Cycle
JCK5F(XXXX)cdf
181 to 3600
147.00
c
(XXXX) denotes the timing period in seconds.
Example: Class 9050 Type JCK1F60 is an On Delay timer fixed at 60 seconds.
d
Fixed repeat cycle timers can be supplied with the same or different On-Time and
Off-Time.
e
Initiating contact can be up to 50 feet from the timer.
f
Voltage code must be specified to order this product. Refer to standard voltage codes
listed below and insert as shown in How To Order.
On Delay

98.00
98.00
98.00
98.00
98.00
107.00
107.00
107.00
107.00

Repeat
Cyclea

Break

Type

JCK41f
JCK42f
JCK43f
JCK44f
JCK45f
JCK46f
JCK47f
JCK48f
JCK49f

Res. 75% P.F.
Make Break and
Continuous

Timing Mode

One Shot
$ Price Power
Trigger $ Price

Make

Table 23.143: Fixed Time Delay

One Shotb

Continuous

$ Price

Break

On
Delay

Make

Knob Adjustable
Timing Range

E78351
NLDX

File
Class

Two 5 position rotary switches are used to select the timing mode and
timing range. The three pushbutton thumbwheels are used to select the
time value.

214768
3211 07

Table 23.147: Selection and Pricing
Timing
Timing
Type
$ Price
Modes
Range
On Delay
Off Delay
Same as
Interval
JCK70f
173.00
JCK60
One Shot
Repeat Cycleg
g
The repeat cycle mode utilizes the same
on-time and off-time.

Without Socket
File
CCN

RoHS
IEC
9050JCK1-5 = 0627
60947-1 as Compliant
of date code 9050JCK6070=0648

E78351
NLDX2

Table 23.144: Voltage Codes
Voltage
12 Vdc
24 Vac/Vdc
48 Vac/Vdc
120 Vac/110 Vdc
240–50/60 Vac

Code
V36
V14
V17
V20
V24

Table 23.148: Class 8501 Hold Down Spring
For use on Class 9050 Type JCK Timers
Hold down spring holds timer in socket during heavy vibration.
(See 9050JCK with 8501NH7 photo at the top of this page.)

Class

Type

$ Price ea.

8501

NH7

8.30

Table 23.149: How to Order
To Order Specify:

•
•
•

23-30

CP2

Discount
Schedule

Class Number
Type Number
Voltage Code

Catalog Number
Class

Type

9050

JCK11

Voltage
Code
V20
© 2012 Schneider Electric
All Rights Reserved

Control and Measurement
Relays

Type REG
Refer to Catalog 8430CT0601

www.schneider-electric.us

Zelio™ Temperature Controllers
The new Zelio REG temperature controllers offer seamless interfacing with solid state relays, electromechanical relays,
PLCs, variable speed drives and HMI displays make them a key component to controlling the temperature in your
process.
Offer includes 3 versions:

•
•
•
REG24PTP1RHU

A 24x48 mm (1/32 DIN) cost effective solution for basic temperature control needs.
A 48x48 mm (1/16 DIN) balanced version for optimal price and functionality.
A 96x48 mm (1/8 DIN) full-featured version for complete performance and function.

Key features include:

•
•
•
•
•
•
•

Modbus communication for easy data exchange with other automation products
Simple parameter settings
IP66 certification enables dust resistance
Flash memory (saves configurations)
Compatible with a wide range of sensors
Advanced Functions (standard): PID, fuzzy logic, auto-tuning, soft start
Optimized programming
—
—
—
—

Common software for all products in the temperature relay range (freely downloadable from www.schneider-electric.us).
A single cable enables connection to both a computer and PLCs.
Simple adjustment of parameters.
Saving of configurations.

Table 23.150: Zelio Temperature Controllers
REG48PUN1RHU

Input Type

Number and
Type of Outputs

Alarms

Communication
on Modbus

Catalog Number

1 electromechanical relay
1 electromechanical relay
1 solid state relay
1 solid state relay
1 analog interface (4–20 mA)
1 electromechanical relay
1 solid state relay
1 analog interface (4–20 mA)
1 electromechanical relay
1 solid state relay
1 electromechanical relay
1 solid state relay

No
1
No
1
No
No
No
No
No
No
No
No

Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

REG24PTP1RHU
REG24PTP1ARHU
REG24PTP1LHU
REG24PTP1ALHU
REG24PTP1JHU
REG24PTP1RLU
REG24PTP1LLU
REG24PTP1JLU
REG24PUJ1RHU
REG24PUJ1LHU
REG24PUJ1RLU
REG24PUJ1LLU

209.00
186.00
216.00
192.00
219.00
209.00
216.00
219.00
209.00
216.00
219.00
216.00

1 electromechanical relay

2

2 electromechanical relays

2

Yes
No
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

REG48PUN1RHU
REG48PUNL1RHU
REG48PUN2RHU
REG48PUN1LHU
REG48PUNL1LHU
REG48PUN2LRHU
REG48PUN1JHU
REG48PUN2LJHU
REG48PUN1RLU
REG48PUN2RLU
REG48PUN1LLU
REG48PUN2LRLU
REG48PUN1JLU
REG48PUN2LJLU

252.00
226.00
292.00
258.00
234.00
295.00
260.00
298.00
252.00
292.00
258.00
295.00
260.00
298.00

Yes
No
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

REG96PUN1RHU
REG96PUNL1RHU
REG96PUN2RHU
REG96PUN1LHU
REG96PUNL1LHU
REG96PUN2LRHU
REG96PUN1JHU
REG96PUN2LJHU
REG96PUN1RLU
REG96PUN2RLU
REG96PUN1LLU
REG96PUN2LRLU
REG96PUN1JLU
REG96PUN2LJLU

336.00
311.00
381.00
343.00
317.00
383.00
345.00
385.00
336.00
381.00
343.00
384.00
345.00
385.00

Supply Voltage

$ Price

28 x 48 Size — 1/32 DIN Standard

100/240 Vac
Thermocouple
PT100 Probe
24 Vac/Vdc
100/240 Vac
Voltage/current
24 Vac/Vdc

Universal

REG96PUN1RHU
24 Vac/Vdc

1 solid state relay

2

1 solid state relay + 1 electromechanical relay
1 analog interface (4–20 mA)
1 solid state relay + 1 analog interface (4–20 mA)
1 electromechanical relay
2 electromechanical relays
1 solid state relay
1 solid state relay + 1 electromechanical relay
1 analog interface (4–20 mA)
1 solid state relay + 1 analog interface (4–20 mA)

2
2
2
2
2
2
2
2
2

1 electromechanical relay

3

2 electromechanical relays

3

98 x 48 Size — 1/8 DIN Standard

100/240 Vac

Universal

24 Vac/Vdc

1 solid state relay

3

1 solid state relay + 1 electromechanical relay
1 analog interface (4–20 mA)
1 solid state relay + 1 analog interface (4–20 mA)
1 electromechanical relay
2 electromechanical relays
1 solid state relay
1 solid state relay + 1 electromechanical relay
1 analog interface (4–20 mA)
1 solid state relay + 1 analog interface (4–20 mA)

3
3
3
3
3
3
3
3
3

Table 23.151: Temperature Controller Accessories
Description

For Use With Relays

Sold In Lots Of

Catalog Number

Bracket for mounting on DIN rail

24 x 48 mm (1/32 DIN)
48 x 48 mm (1/16 DIN)
96 x 48 mm (1/8 DIN)

4
2
2

REG24PSOC
REG48PCOV
REG96COV

Terminal block cover

© 2012 Schneider Electric
All Rights Reserved

CP2

Discount
Schedule

$ Price
21.90
30.30
37.10

23-31

23

100/240 Vac

RELAYS AND TIMERS

48 x 48 Size — 1/16 DIN Standard

Control and Measurement
Relays

RM17JC & RM35JA
Refer to Catalog 8430CT0601

www.schneider-electric.us

Zelio™ Current Measurement Relays
Zelio Current Measurement Relays are designed to measure under and overcurrent, without external sensors. Current
measurement relays enable continuous monitoring of the operation of electrical and mechanical loads such as motors
and resistors. They are DIN rail mountable and the control status is indicated by an LED.
RM17JC Current Control Relay

RM35JA Current Control Relays

•
•
•

•
•
•

Monitors a.c. currents
Designed to monitor overcurrent
Equipped with an integrated current transfmormer

Selection between overcurrent or undercurrent
Automatic d.c. or a.c. recognition
Selectable memory function

Table 23.152:
RM17JC00MW

Measurement Range

Supply Voltage

a

Rangea

Width

Output
5Amps

Terminals

Inches

mm

Catalog Number

$ Price

2–20 A
N/A
1 C/O
0.69
17.50
RM17JC00MW
2–20 mA
E1-M
RM35JA31MW
10–100 mA
E2-M
24–240 Vac/dc
50–500 mA
E3-M
2 C/O
1.38
35.00
0.15–1.5 A
E1-M
RM35JA32MW
0.5–5 A
E2-M
1.5–15 A
E3-M
Above 15A, a current transformer can be connected (for RM35JA3•MW). See page 57 of the catalog for suggested wiring.

130.00
148.00

177.00

Table 23.153: Output Characteristics and Measurement Circuit Characteristics
Type of Relay

RM17JC00MW

RM35JA31MW

RM35JA31MW

RM35JA32MW

Plus or minus 10% of the full scale value

Setting accuracy
Repeat accuracy (with constant parameters)
Hysteresis
Time delay accuracy (with constant parameters)
Time delay on pick-up
Conforming to standards
Storage
Ambient air temperature around the
device
Operational

15% of the threshold setting, fixed
N/A
500ms

Plus or minus 0.5%
5 to 50% of the threshold setting, adjustable
plus or minus 2%
300ms
NF EN 60255-6
-40 to 158 degrees F (-40 to +70°C)
-4 to 122 degrees F (-20 to +50°C)

Approvals:

23

File
CNN

E173076
NRNT

File
Class

217698
3211 07

CE: 73/23/EEC and
EMC 89/336/EEC

GL, C-Tick, GOST,
RoHS

Approximate Dimensions
RELAYS AND TIMERS

RM35JA32MW

RM35JA3•MW

RM17JC00MW
17.5
0.69

97/3.82

35/1.38

72/2.83

A1 A2 E3 E2 E1 M

1 C/O =

90/3.54

90/3.54

10/0.39

2.8
0.11

2.8
0.11

2 C/O =
12 11 14 22 21 24

76/2.99
72.5/2.85

101/3.98
97.5/3.84

Dual Dimensions:

23-32

CP2

Discount
Schedule

INCHES
Millimeters

© 2012 Schneider Electric
All Rights Reserved

Control and Measurement
Relays

RM17T•00
Refer to Catalog 8430CT0601

www.schneider-electric.us

Zelio™ Phase Measurement Relays
Zelio Phase Measurement Relays monitor their own power supply. Relay status is indicated by an LED and they are
DIN rail mountable.
RM17TG•0 measurement and control relays are for monitoring of 3-phase supplies for the correct sequencing of
phases L1, L2, and L3, as well as the total loss of one or more phases.
Table 23.154: 3-Phase supply control relays
Supply
Voltage

RM17TG•0

208–480 Vac
208–440 Vac

Detection
Threshold

Output
5 Amps

<100 Vac

1 C/O
2 C/O

Width
inches

Catalog Number

mm

0.69

$ Price

RM17TG00
RM17TG20

17.50

114.00
125.00

Table 23.155: Multifunction 3-phase supply control relays
Width

Supply
Voltage

Voltage
Range

Output
5 Amps

inch

mm

Catalog
Number

208–480 Vac

Selectable voltages:
208, 220, 380, 400,
415, 440, 480

1 C/O

0.69

17.50

$ Price

RM17TT00
RM17TA00
RM17TU00
RM17TE00

136.00
177.00
131.00
217.00

Table 23.156: RM17TT, RM17TA, RM17TU, and RM17TE multifunction control relays monitor the following on
3-phase supplies:

RM17TA00

Function
Sequence of phases L1, L2 and L3
Phase failure with regeneration (0.7 x selected voltage range)
Asymmetry (phase imbalance)
Undervoltage
Overvoltage and undervoltage

RM17TT
Yes
Yes
No
No
No

RM17TA
Yes
Yes
Yes
No
No

RM17TU
Yes
Yes
No
Yes
No

RM17TE
Yes
Yes
Yes
No
Yes

Table 23.157: 3-phase supply and motor temperature control relays
Supply
Voltage

Measurement
Range

220–480 Vac

Width

Output
5 Amps

208–480 Vac

inch

2 N.O.

Catalog
Number

mm

1.38

35.00

$ Price

RM35TM50MW
RM35TM250MW

221.00
231.00

Table 23.158: RM35TM control relays monitor the following on 3-phase supplies:
RM17TE00

Function
Sequence of phases L1, L2 and L3
Phase failure
Motor temperature via PTC probe
Selection (with or without memory)
Test-reset button

RM35TM50MW
Yes
Yes
Yes
No
No

RM35TM250MW
Yes
Yes
Yes
Yes
Yes

Table 23.159: Multifunction 3-phase supply control relays
Supply
Voltage

Measurement
Range

Output
5 Amps

220–480 Vac

194–528 Vac

2 C/O

Width
inch
1.38

mm
35.00

Catalog
Number

$ Price

RM35TF30

273.00

Approvals:
RM35TM••MW

File
CNN

E173076
NRNT

File
Class

217698
3211 07

CE: 73/23/EEC and
EMC 89/336/EEC

GL, C-Tick, GOST,
RoHS

RM35•

23

Approximate Dimensions
RM17•

90/3.54

90/3.54

RM35TF30

17.5
0.69

72/2.83

35/1.38

72/2.83

2.8
0.11

2.8
0.11

1 C/O =
2 C/O =
2 N/O =

76/2.99

76/2.99

72.5/2.85

72.5/2.85
Dual Dimensions:

© 2012 Schneider Electric
All Rights Reserved

CP2

Discount
Schedule

RELAYS AND TIMERS

RM35TF30 measurement and control relay is for monitoring of phase sequence, phase failure, asymmetry,
undervoltage and overvoltage in window mode.

INCHES
Millimeters

23-33

Control and Measurement
Relays

RM17UB, RM35UB, RM17UAS, RM17UBE, RM35UA1•MW
Refer to Catalog 8430CT0601

www.schneider-electric.us

Zelio™ Voltage Measurement Relays
Zelio Voltage Measurement Relays are DIN rail mountable and relay status is indicated by an LED.
Single phase and d.c. voltage measurement and control relays RM17UAS•• and RM17UBE•• monitor:

•
•
•
•

Overvoltage
Undervoltage
Overvoltage and undervoltage (window mode)
Nominal voltages

Table 23.160: Single-phase and d.c. voltage control relays
RM17UB310

Supply Voltage

Ranges Controlled

12 Vdc
24–48 Vac/Vdc
110–240 Vac/Vdc
24–48 Vac/Vdc
110–240 Vac/Vdc

9–15 Vdc
20–80 Vac/Vdc
65–260 Vac/Vdc
20–80 Vac/Vdc
65–260 Vac/Vdc

a
b

Width

Output 5 A

in.

1 C/O

Catalog Number

mm

0.69

$ Price

RM17UAS14a
RM17UAS16a
RM17UAS15a
RM17UBE16b
RM17UBE15b

17.50

138.00
138.00
138.00
146.00
146.00

Provides overvoltage or undervoltage protection.
Provides overvoltage and undervoltage protection in window mode.

Multifunction voltage control relays RM35UA1•MW monitor both a.c. and d.c. voltages.

•
•
RM35UB3•••

Automatic Vdc or Vac recognition
Selection between overvoltage and undervoltage

Table 23.161: Multifunction voltage control relays
Supply Voltage

24–240 Vac/Vdc

Measurement Range
Ranged
0.05–0.5 V
0.3–3 V
0.5–5
1–10
5–50
10–100
15–150
30–300
60–600

Width

Output
5A

Terminals
E1-M
E2-M
E3-M
E1-M
E2-M
E3-M
E1-M
E2-M
E3-M

in.

Catalog
Number

mm

$ Price

RM35UA11MW
157.00
RM35UA12MW
2 C/O

1.38

35.00

157.00
RM35UA13MW
157.00

3-phase voltage control relays monitor:
RM17UAS••

23

•
•
•
•
•

Failure of one or more phases
Voltage between phases
Absence of neutral
Voltage between phases and neutral
Overvoltage and undervoltage

Table 23.162: Three-phase voltage control relays
RELAYS AND TIMERS

c
d

Rated 3-Phase
Supply Voltage Vac

Measurement Range

Output
5A

220–480 phase-phase
120–277 phase-neutral
120–277 phase-neutral

195–528 Vac
183–528 Vac
114–329 Vac

1 C/O + 1 C/O 1 per threshold
1 C/O
1 C/O + 1 C/O 1 per threshold

Width
in.
1.38
0.69
1.38

mm
35.00
17.50
35.00

Catalog
Number

$ Price

RM35UB330c
RM17UB310c
RM35UB3N30d

229.00
189.00
254.00

Provides overvoltage and undervoltage protection between phases.
Provides overvoltage and undervoltage protection between phases and neutral and absence of neutral.

Approvals:
File
CNN

E173076
NRNT

File
Class

217698
3211 07

CE: 73/23/EEC and
EMC 89/336/EEC

GL, C-Tick,
GOST, RoHS

RM35UA1•MW

Approximate Dimensions
RM35•

RM17•
17.5
0.69

72/2.83

35/1.38

72/2.83
1 C/O =

2.8
0.11

2.8
0.11

90/3.54

90/3.54

2 C/O =

76/2.99

76/2.99

72.5/2.85

72.5/2.85
Dual Dimensions:

23-34

CP2

Discount
Schedule

INCHES
Millimeters

© 2012 Schneider Electric
All Rights Reserved

Control and
Measurement Relays

RM35L•••MW, RM35BA10
Refer to Catalog 8430CT0601

www.schneider-electric.us

Zelio™ Level Control Relays and Zelio™ Pump Control Relays
Zelio level control relays control one or two levels with fill or empty function. The settings are protected by a sealable
cover, control status is indicated by an LED, and they are DIN rail mountable. RM35LM is designed to control levels of
conductive liquid, and RM35LV is designed to control levels of other materials.

RM35LM33MW

Application examples for RM35LM:

•

•
•
•
•
•

Application examples for RM35LV:

Detecting pump seal failures
Spring, town, industrial and sea water
Metallic salt, acid or base solutions
Liquid fertilizers
Non-concentrated alcohol (<40%)

•
•
•
•

Liquids in the food-processing industry: milk, beer, coffee, etc.
Chemically pure water
Fuels, liquid gasses (inflammable)
Oil, concentrated alcohol (>40%)
Ethylene, glycol, paraffin, varnish and paints

Table 23.163: Level Control Relays
Time Delay on
Crossing the
Threshold

0.1–5 seconds,
0 + 10%

Function

Output Relay

Detection by resistive
probes

2 C/O, 5A

Detection by discrete
sensors

1 C/O, 5A

Supply Voltage
50/60 Hz

Measurement
Ranges

Catalog Number

250 Ω –5 k Ω
5 k Ω –100 k Ω
50 k Ω –1 M Ω

24–240 Vac/Vdc

$ Price

RM35LM33MW
115.00

—

RM35LV14MW

146.00

Table 23.164: Probes
°F

°C

Maximum
pressure
kg/cm2

Catalog
Number

3

176

80

2

RM79696044

78.00

1

392

25

200

RM79696014

95.00

Application

No. of
probes

Recommended for drink vending machines and where
installation space is limited (stainless steel)a
Suitable for boilers, pressure vessels, and under high
temperature conditions (1) (304 stainless steel)a

RM35LV14MW

a

Operating temperature

$ Price

3/8” BSP mounting thread with hexagonal head. Use a 24mm spanner for tightening.

Table 23.165: Probes
Description
Protected probe for mounting by suspension, protective shell PUC (S7) Electrode: stainless steel
Liquid level control probe, suspended by cable, maximum operating temperature 212°F/100°Cb
b

Catalog
Number
RM79696043
LA9RM201

$ Price

Catalog
Number
RM79696006

$ Price

57.00
83.00

3/8” BSP mounting head.

RM79696043

Table 23.166: Electrode Holders
Description

Material

Electrode for use up to 662°F (350°C)

Stainless steel isolated by ceramic

62.00

Pump control relay RM35BA10 can operate on a single-phase or 3-phase supply. It incorporates three functions in a
signal unit:

•

Over and under current measurement

•

Phase presence control

Single or three phase

It has two operating modes which are designed to control a pump via two external signal inputs (Y1 Y2). These two
signals are controlled by volt-free contacts. Control inputs Y1 and Y2 can be connected to:

•

•

Level sensor

•

Level relay

•

Pressure sensor

Push button

Table 23.167: Pump Control Relay
LA9RM201

Description

Current Range Controlled

Pump Control Relay

Supply Voltage
208–480 Vac, 3 phase
230, single-phase

1–10 A

Output

Catalog Number

1 C/O 5 A

RM35BA10

$ Price
284.00

RELAYS AND TIMERS

•

Approvals:
E173076
NRNT

File
Class

217698
3211 07

CE: 73/23/EEC and
EMC 89/336/EEC

GL, C-Tick, GOST,
RoHS

23

File
CNN

RM79696006

Approximate Dimensions
RM35BA10
35/1.38

72/2.83

35/1.38

E1

L1 L2 L3

90/3.54

>I

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2014:05:30 13:54:30-05:00
Modify Date                     : 2014:05:30 13:54:30-05:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2014:05:30 13:54:30-05:00
Format                          : application/pdf
Document ID                     : uuid:960a6f7e-3616-49c5-8199-7233e4b40f3e
Instance ID                     : uuid:537da270-c9f2-42e6-a47d-f3e7174972b4
Page Mode                       : UseNone
Page Count                      : 42
EXIF Metadata provided by EXIF.tools

Navigation menu