GE Specialty Control Devices

GE Industrial Solenoids
CR9503 Heavy-Duty Solenoids
Application
Used to apply a mechanical force in a straight line, in a push or
pull motion.
In applying solenoids, it is important that the load be kept as close
to the recommended value as possible. If larger loads are used,
action will be sluggish, and there will not be enough margin of pull
to compensate for line-voltage variations, so that burned-out coils
may result. If too light a load is used, the excess energy results in
excessive hammer blows on the solenoid and reduces its life.

Ordering Directions
Order a solenoid by complete Catalog Number. Example:
CR9503211EAB272 at $266.00, GO-10G7.
Typical CR9503211E
Industrial Solenoid

AC Solenoids
Ratings (Maximum Ambient Temperature 40 C)

%
1
1
1!/>
1
1'/4

w
2
2
3
3

Exclusive of
Plunger

0.65
0.90
3.20
4.00
5.50
10.2
22.7
21.7
42.0
51.0
70.0

For Operation
with Gravity
(Weight of
Plunger Added)

For Operation
Against Gravity
(Less Plunger
Weight)

Pull

Push

Pull

Push

0.77
1.08
3.51
4.56
6.18
11.1
25.1
25.0
47.4
61.0
83.0

_
—
3.7
4.8

0.53
0.72
2.89
3.44
4.82
9.26
20.3
18.5
36.6
41.0
57.0

_
—

6.38
11.4
26.1
26.5
49.1
67.0
89.0

Pull Type

Gross Load at Rated Voltage in Lbs.

Recommended Load in Lbs.
Max.
Stroke
in
Inches

Exclusive of
Plunger

2.70
3.20
4.62
9.01
19.3
17.0
34.9
35.0
51.0

For Operation
with Gravity
(Weight of
Plunger Added)
Pull

0.90
1.30
4.50
6.00
8.00
14.0
30.0
30.2
64.0
73.0
97.0

1.02
1.48
4.81
6.56
8.68
14.9
32.4
33.5
69.4
83.0

110

Push

—
5.0
6.8
8.88
15.2
33.4
35.0
71.1
89.0

116

Weight of
Plunger in
Lbs.

For Operation
Against Gravity
(Less Plunger
Weight

Catalog
Number
CR9503

Pull

Push

Pull

Push

0.78
1.12
4.19
5.44
7.32
13.1
27.6
27.0
58.6
63.0
84.0

_
—
4.0
5.2

0.12
0.18
0.31
0.56
0.68
0.94
2.44
3.25
5.44
10.0
13.0

0.50
0.80
0.88
1.19
3.38
4.75
7.12
16.0
19.0

7.12
12.81
26.6
25.5
56.9
57.0
78.0

List
Price,
GO-10G7

207EAB*
208DAB*
209CAB*
210CAB*
209MAB*
211EAB*
206BAB*
212BAB*
213CAB*
214BAB*
215CAB*

—

Push Type

$

60.00
86.00
189.00
240.00
240.00
266.00
387.00
516.00
618.00
975.00
1149.00

Catalog
Number
CR9503

List
Price,
GO-10G7

—

—

209CAC*
210CAC*
209MAF*
211EAC*
206BAC*
212BAF*
213CAF*
214BAF*
215CAF*

$ 204.00
258.00
258.00
281.00
423.00
546.00
660.00
1002.00
1206.00

* Insert three-digit suffix from table below to complete the catalog number.

Coil Suffix Table—AC Solenoids
Voltage
60 Hertz

206B

207E

208D

209C

209M

Size of Solenoid CR9503
21 OC

211E

21 2B

213C

214B

21 5C

110
120
200
220
240
380
400
440
480
500
550

202
349
334
201
263
442
409
203
348
453
204

202
—
—
203
—
—
—
204
—
—
205

202
377
251
203
384
—
—
204
494
412
205

202
289
293
201
529
557
531
204
502
523
226

204
232
233
234
—
—
—
235
236
237
238

201
260
—
202
240
—
287
203
237
—
204

271
499
513
272
509
593
559
273
523
514
274

207
293
298
201
265
299
297
205
285
—
206

204
254
236
201
247
312
—
203
309
234
205

213
247
—
209
252
249
242
210
243
241
211

212
307
310
245
265
292
—
246
274
224
247

Coil Rating in Voltamperes
Size of Solenoid
CR9503
206B
207E
208D
209C
209M
211E
21 2B
21 3C
214B
21 5C

Reference: (CR9503)
Renewal parts GEF-4245

Prices and data subject to change without notice

1999 Issue

60 Hertz
Max. Stroke (Inrush)
5450
110'

210
500
750
1970
6900
12600
24200
31200

Min. Stroke (Holding)

390
25
35
55
85
165
510
715
1290
1760

10-7

GE Specialty Control Devices

GE Industrial Solenoids
CR9503 Heavy-Duty Solenoids
Technical Information
CR9503 Solenoids—AC Devices (Maximum Ambient Temperature 40°C)
Pull Type

For Operation
with Gravity
(Weight of
Plunger
Added)

Max.

Catalog
Number
CR9503

207EAB*
208DAB*
209CAB*
210CAB*
209MAB*
211EAB*
206BAB*
212BAB*
213CAB*
214BAB*
21 SCAB*

Gross Pull or Push at Rated
Voltage in Lbs.

Recommended Load in Lbs.

Push Type

Stroke
in
Inches

Catalog
Number
CR9503

Exclusive of
Plunger

%
1
1

—
209CAC*
210CAC*
209MAF*
211EAC*
206BAC*
212BAF*
213CAF*
214BAF*
215CAF*

Pull
Type

Push
Type

0.77
1.08
3.51
4.56
6.18

—
3.7
4.8

11.14

11.39

25.1
25.0
47.4
61.0
83.0

26.1
26.5
49.1
67.0
89.0

0.65

0.9
3.2
4.0
5.5

1'/4

1
11/4
1%
2
2
3
3

10.2
22.7
21.7
42.0
51.0
70.0

For Operation
Aga inst
Gravity
(Less F lunger
Wei grit)

Pull
Type

Exclusive of
Plunger

.53
.72

Push
Type

1.02
1.48
4.81
6.56
8.68

—
5.0
6.8
8.88

1.12
4.19
5.44
7.32

14.94

15.19

13.06

12.81

32.4
33.5
69.4
83.0

33.4
35.0
71.1
89.0

110.0

116.0

27.6
27.0
58.6
63.0
84.0

26.6
25.5
56.9
57.0
78.0

0.9
1.3
4.5
6.0
8.0

—
2.7
3.2
4.62
9.01
19.3
17.0
34.9
35.0
51.0

14.0
30.0
30.2
64.0
73.0
97.0

Weight
of
Plunger
in

For Operation
Aga inst
Gra vity
(Less F 'lunger
We ght)

Pull
Type

Push
Type

2.89
3.44
4.82
9.26
20.3
18.5
36.6
41.0
57.0

6.38

For Operation
with Gravity
(Weight of
Plunger
Added)

Lbs.

Lbs.

Push
Type

Pull
Type

.78

Approx.
Shipping
Weight
in

Pull
Type
0.12
0.18
0.31
0.56
0.68
0.94
2.44
3.25
5.44
10.0
13.0

—
4.0
5.2
7.12

Push
Type

2
2
2V&
4te

—
0.5
0.8

1

0.88
1.19
3.38
4.75
7.12
16.0
19.0

4 /4

m
14
24
31
67
90

60 Hertz, Alternating Current

Maximum Duty Cycle
(Operations per Minute)
The adjoining table gives
typical maximum operating
speeds for the 60 Hertz ac
solenoids listed. The ratings
are based on operation at
rated voltage with the
recommended load shown
in the table.

Recommended
Load
in Lbs.

CR9503
Solenoid

25 Percent Time On

50 Percent Time On

Percent Stroke

Percent Stroke

50

50

100

75

75

75 Percent Time On
Percent Stroke

50

100

75

100

No. of Operations per Minute
206B
207E
208D
209C
209M

22.7
0.65

211E
212B

10.2
21.7
42.0
51.0
70.0

58
220
150
85
85
70
65
54
45
40

0.9
3.2
5.5

21 3C
214B

21 5C

24
100
71
42
42

42
160
130
68
68
60
51
45
35
26

11.5

39
25
19
19

31.5

13.5

29
22
27
25

14
12
13
13

18
67
58
37
37
27
24
19
20
15

10
28
20
17
17
12

18
115
78
62
62
50
40
36
25
18

11.5

9
9
9

12
41
36
33
33
22

6.5
19
15
15
15
11
9
6
6
6

21.4
14.5

13
10

DC Solenoids
Ratings (Maximum Ambient Temperature 40 C)
Recommended Load in Lbs.
Max.

Stroke
in
Inches

i
1'/4

1%
2
2
3
3

Exclusive of
Plunger
Weight)
3.10
12.0
36.0
43.0
42.0
35.0
59.0

Gross Load at Rated Voltage in Lbs.

For Operation
with Gravity
(Weight of
Plunger Added)

For Operation
Against Gravity
(Less Plunger
Weight)

Pull

Push

Pull

Push

3.41
12.9
38.4
46.3
47.4
45.0
72.0

3.60
13.2
39.4
47.8
49.1
51.0
78.0

2.79
11.1
33.6
39.8
36.6
25.0
46.0

2.60
10.8
32.6
38.3
34.9
19.0
40.0

For Operation
Against Gravity
(Less Plunger
Weight

Pull

Push

Pull

5.51
17.9
52.4
60.3
63.4
60.0
94.0

5.70
18.2
53.4
61.8
65.1
66.0

4.89
16.1
47.6
53.8
52.6
40.0
68.0

Exclusive of
Plunger
Weight
5.20
17.0
50.0
57.0
58.0
50.0
81.0

Pull Type

For Operation
with Gravity
(Weight of
Plunger Added)

100.0

Push
4.70
15.8
46.6
52.3
50.9
34.0
62.0

Weight of
Plunger in
Lbs.

Pull

Push

0.31
0.94
2.44
3.25
5.44
10.0
13.0

0.50
1.19
3.38
4.75
7.12
16.0
19.0

Push Type

Catalog
Number
CR9503

List
Price,
GO-10G7

Catalog
Number
CR9503

List
Price,
GO-10G7

209CANt
211EBFt
206BAFt
212BATt
213CASt
214BASt
215CASt

258.00®
348.00
480.00
597.00
705.00
1068.00
1254.00

209CAOt
211EBGt
206BAGt
212BAUt
213CATt
214BATt
215CATt

273.00®
357.00
501.00
624.00
744.00
1125.00
1308.00

t Insert one-, two-, or three-digit number from DC Coil Suffix table below. Use with dc forms only.
® Price for 440 Volt and 550 Volt forms is $291.00 each, GO-10G7.
® Price for 440 Volt and 550 Volt forms is $306.00 each, GO-10G7.

t Coil Suffix Table—DC Solenoids
Voltage
DC
110
125
230
250
440
550

115/125
230/250

Size of Solenoids CR9503
206B

209C

211E

48
1
44
2
43
3
62
63

93
5
104
1
—
34®
131
132

141
10
110
1
84
9
138
139

212B

21 3C

214B

3
37
1
—

2
24
1
—
3
—
—

2
—
1
—
—
—
—

4
—
—

21 5C
22
2
23
1
20
—
—

Requires a 4000-ohm, 100-watt resistor mounted in series.

10-8

Reference: (CR9503)
Renewal parts GEF-4245

1999 Issue

Data subject to change without notice



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Modify Date                     : 2003:04:23 20:59:36+05:30
Create Date                     : 2003:04:23 20:59:20+05:30
Title                           : 
Subject                         : 
Author                          : 
Creator                         : ABBYY FineReader
Producer                        : 
Page Count                      : 2
Mod Date                        : 2003:04:23 20:59:36+05:30
Creation Date                   : 2003:04:23 20:59:20+05:30
Metadata Date                   : 2003:04:23 20:59:36+05:30
EXIF Metadata provided by EXIF.tools

Navigation menu