Product Detail Manual
2014-10-23
: Pdf 614580-Attachment 614580-Attachment Batch9 unilog
Open the PDF directly: View PDF
.
Page Count: 2

GE
Specialty Control Devices
GE
Industrial Solenoids
CR9503
Heavy-Duty Solenoids
Application
Used
to
apply
a
mechanical
force
in a
straight
line,
in a
push
or
pull
motion.
In
applying
solenoids,
it is
important
that
the
load
be
kept
as
close
to the
recommended
value
as
possible.
If
larger
loads
are
used,
action
will
be
sluggish,
and
there
will
not be
enough
margin
of
pull
to
compensate
for
line-voltage
variations,
so
that
burned-out
coils
may
result.
If too
light
a
load
is
used,
the
excess
energy
results
in
excessive
hammer
blows
on the
solenoid
and
reduces
its
life.
Ordering Directions
Order
a
solenoid
by
complete
Catalog
Number.
Example:
CR9503211EAB272
at
$266.00,
GO-10G7.
Typical CR9503211E
Industrial
Solenoid
AC
Solenoids
Ratings
(Maximum Ambient
Temperature
40 C)
Max.
Stroke
in
Inches
%
1
1
1!/>
1
1'/4
w
2
2
3
3
Recommended
Load
in
Lbs.
Exclu-
sive
of
Plunger
0.65
0.90
3.20
4.00
5.50
10.2
22.7
21.7
42.0
51.0
70.0
For
Operation
with
Gravity
(Weight
of
Plunger Added)
Pull
0.77
1.08
3.51
4.56
6.18
11.1
25.1
25.0
47.4
61.0
83.0
Push
_
—
3.7
4.8
6.38
11.4
26.1
26.5
49.1
67.0
89.0
For
Operation
Against Gravity
(Less
Plunger
Weight)
Pull
0.53
0.72
2.89
3.44
4.82
9.26
20.3
18.5
36.6
41.0
57.0
Push
_
—
2.70
3.20
4.62
9.01
19.3
17.0
34.9
35.0
51.0
Gross
Load
at
Rated Voltage
in
Lbs.
Exclu-
sive
of
Plunger
0.90
1.30
4.50
6.00
8.00
14.0
30.0
30.2
64.0
73.0
97.0
For
Operation
with
Gravity
(Weight
of
Plunger
Added)
Pull
1.02
1.48
4.81
6.56
8.68
14.9
32.4
33.5
69.4
83.0
110
Push
—
5.0
6.8
8.88
15.2
33.4
35.0
71.1
89.0
116
For
Operation
Against Gravity
(Less
Plunger
Weight
Pull
0.78
1.12
4.19
5.44
7.32
13.1
27.6
27.0
58.6
63.0
84.0
Push
_
—
4.0
5.2
7.12
12.81
26.6
25.5
56.9
57.0
78.0
Weight
of
Plunger
in
Lbs.
Pull
0.12
0.18
0.31
0.56
0.68
0.94
2.44
3.25
5.44
10.0
13.0
Push
—
0.50
0.80
0.88
1.19
3.38
4.75
7.12
16.0
19.0
Pull Type
Catalog
Number
CR9503
207EAB*
208DAB*
209CAB*
210CAB*
209MAB*
211EAB*
206BAB*
212BAB*
213CAB*
214BAB*
215CAB*
List
Price,
GO-10G7
$
60.00
86.00
189.00
240.00
240.00
266.00
387.00
516.00
618.00
975.00
1149.00
Push Type
Catalog
Number
CR9503
—
209CAC*
210CAC*
209MAF*
211EAC*
206BAC*
212BAF*
213CAF*
214BAF*
215CAF*
List
Price,
GO-10G7
—
$
204.00
258.00
258.00
281.00
423.00
546.00
660.00
1002.00
1206.00
*
Insert
three-digit
suffix
from
table
below
to
complete
the
catalog number.
Coil Suffix
Table—AC
Solenoids
Voltage
60
Hertz
110
120
200
220
240
380
400
440
480
500
550
Size
of
Solenoid
CR9503
206B
202
349
334
201
263
442
409
203
348
453
204
207E
202
—
—
203
—
—
—
204
—
—
205
208D
202
377
251
203
384
—
—
204
494
412
205
209C
202
289
293
201
529
557
531
204
502
523
226
209M
204
232
233
234
—
—
—
235
236
237
238
21
OC
201
260
—
202
240
—
287
203
237
—
204
211E
271
499
513
272
509
593
559
273
523
514
274
21
2B
207
293
298
201
265
299
297
205
285
—
206
213C
204
254
236
201
247
312
—
203
309
234
205
214B
213
247
—
209
252
249
242
210
243
241
211
21
5C
212
307
310
245
265
292
—
246
274
224
247
Coil Rating
in
Voltamperes
Reference: (CR9503)
Renewal
parts
GEF-4245
Size
of
Solenoid
CR9503
206B
207E
208D
209C
209M
211E
21
2B
21
3C
214B
21
5C
60
Hertz
Max. Stroke (Inrush)
5450
110'
210
500
750
1970
6900
12600
24200
31200
Min.
Stroke
(Holding)
390
25
35
55
85
165
510
715
1290
1760
Prices
and
data subject
to
change
without
notice
1999
Issue
10-7

GE
Specialty
Control
Devices
GE
Industrial Solenoids
CR9503 Heavy-Duty Solenoids
Technical Information
CR9503
Solenoids—AC
Devices (Maximum Ambient Temperature
40°C)
Pull
Type
Catalog
Number
CR9503
207EAB*
208DAB*
209CAB*
210CAB*
209MAB*
211EAB*
206BAB*
212BAB*
213CAB*
214BAB*
21
SCAB*
Push Type
Catalog
Number
CR9503
—
209CAC*
210CAC*
209MAF*
211EAC*
206BAC*
212BAF*
213CAF*
214BAF*
215CAF*
Max.
Stroke
in
Inches
%
1
1
1'/4
1
11/4
1%
2
2
3
3
Recommended Load
in
Lbs.
Exclu-
sive
of
Plunger
0.65
0.9
3.2
4.0
5.5
10.2
22.7
21.7
42.0
51.0
70.0
For
Operation
with
Gravity
(Weight
of
Plunger
Added)
Pull
Type
0.77
1.08
3.51
4.56
6.18
11.14
25.1
25.0
47.4
61.0
83.0
Push
Type
—
3.7
4.8
6.38
11.39
26.1
26.5
49.1
67.0
89.0
For
Op
Aga
Gra
(Less
F
Wei
Pull
Type
.53
.72
2.89
3.44
4.82
9.26
20.3
18.5
36.6
41.0
57.0
eration
inst
vity
lunger
grit)
Push
Type
—
2.7
3.2
4.62
9.01
19.3
17.0
34.9
35.0
51.0
Gross
Pull
or
Push
at
Rated
Voltage
in
Lbs.
Exclu-
sive
of
Plunger
0.9
1.3
4.5
6.0
8.0
14.0
30.0
30.2
64.0
73.0
97.0
For
Operation
with
Gravity
(Weight
of
Plunger
Added)
Pull
Type
1.02
1.48
4.81
6.56
8.68
14.94
32.4
33.5
69.4
83.0
110.0
Push
Type
—
5.0
6.8
8.88
15.19
33.4
35.0
71.1
89.0
116.0
For
Op
Aga
Gra
(Less
F
We
Pull
Type
.78
1.12
4.19
5.44
7.32
13.06
27.6
27.0
58.6
63.0
84.0
eration
inst
vity
'lunger
ght)
Push
Type
—
4.0
5.2
7.12
12.81
26.6
25.5
56.9
57.0
78.0
Weight
of
Plunger
in
Lbs.
Pull
Type
0.12
0.18
0.31
0.56
0.68
0.94
2.44
3.25
5.44
10.0
13.0
Push
Type
—
0.5
0.8
0.88
1.19
3.38
4.75
7.12
16.0
19.0
Approx.
Shipping
Weight
in
Lbs.
2
2
2V&
4te
41/4
m
14
24
31
67
90
Maximum Duty Cycle
(Operations
per
Minute)
The
adjoining
table
gives
typical
maximum
operating
speeds
for the 60
Hertz
ac
solenoids
listed.
The
ratings
are
based
on
operation
at
rated
voltage
with
the
recommended
load
shown
in
the
table.
CR9503
Solenoid
206B
207E
208D
209C
209M
211E
212B
21
3C
214B
21
5C
60
Hertz,
Alternating Current
Recom-
mended
Load
in
Lbs.
25
Percent Time
On
Percent Stroke
50
75
100
50
Percent Time
On
Percent
Stroke
50
75
100
75
Percent Time
On
Percent
Stroke
50
75
100
No. of
Operations
per
Minute
22.7
0.65
0.9
3.2
5.5
10.2
21.7
42.0
51.0
70.0
58
220
150
85
85
70
65
54
45
40
24
100
71
42
42
31.5
29
22
27
25
11.5
39
25
19
19
13.5
14
12
13
13
42
160
130
68
68
60
51
45
35
26
18
67
58
37
37
27
24
19
20
15
10
28
20
17
17
12
11.5
9
9
9
18
115
78
62
62
50
40
36
25
18
12
41
36
33
33
22
21.4
14.5
13
10
6.5
19
15
15
15
11
9
6
6
6
DC
Solenoids
Ratings
(Maximum
Ambient
Temperature
40 C)
Max.
Stroke
in
Inches
i
1'/4
1%
2
2
3
3
Recommended
Load
in
Lbs.
Exclu-
sive
of
Plunger
Weight)
3.10
12.0
36.0
43.0
42.0
35.0
59.0
For
Operation
with Gravity
(Weight
of
Plunger Added)
Pull
3.41
12.9
38.4
46.3
47.4
45.0
72.0
Push
3.60
13.2
39.4
47.8
49.1
51.0
78.0
For
Operation
Against Gravity
(Less Plunger
Weight)
Pull
2.79
11.1
33.6
39.8
36.6
25.0
46.0
Push
2.60
10.8
32.6
38.3
34.9
19.0
40.0
Gross
Load
at
Rated Voltage
in
Lbs.
Exclu-
sive
of
Plunger
Weight
5.20
17.0
50.0
57.0
58.0
50.0
81.0
For
Operation
with Gravity
(Weight
of
Plunger Added)
Pull
5.51
17.9
52.4
60.3
63.4
60.0
94.0
Push
5.70
18.2
53.4
61.8
65.1
66.0
100.0
For
Operation
Against Gravity
(Less
Plunger
Weight
Pull
4.89
16.1
47.6
53.8
52.6
40.0
68.0
Push
4.70
15.8
46.6
52.3
50.9
34.0
62.0
Weight
of
Plunger
in
Lbs.
Pull
0.31
0.94
2.44
3.25
5.44
10.0
13.0
Push
0.50
1.19
3.38
4.75
7.12
16.0
19.0
Pull Type
Catalog
Number
CR9503
209CANt
211EBFt
206BAFt
212BATt
213CASt
214BASt
215CASt
List
Price,
GO-10G7
258.00®
348.00
480.00
597.00
705.00
1068.00
1254.00
Push Type
Catalog
Number
CR9503
209CAOt
211EBGt
206BAGt
212BAUt
213CATt
214BATt
215CATt
List
Price,
GO-10G7
273.00®
357.00
501.00
624.00
744.00
1125.00
1308.00
t
Insert
one-,
two-,
or
three-digit
number
from
DC
Coil
Suffix
table
below.
Use
with
dc
forms only.
®
Price
for
440
Volt
and
550
Volt forms
is
$291.00
each,
GO-10G7.
®
Price
for 440
Volt
and 550
Volt forms
is
$306.00
each,
GO-10G7.
t
Coil
Suffix
Table—DC
Solenoids
Voltage
DC
110
125
230
250
440
550
115/125
230/250
Size
of
Solenoids
CR9503
206B
48
1
44
2
43
3
62
63
209C
93
5
104
1
—
34®
131
132
211E
141
10
110
1
84
9
138
139
212B
3
37
1
—
4
—
—
21
3C
2
24
1
—
3
—
—
214B
2
—
1
—
—
—
—
21
5C
22
2
23
1
20
—
—
Requires
a
4000-ohm,
100-watt
resistor
mounted
in
series.
Reference:
(CR9503)
Renewal parts GEF-4245
10-8
1999
Issue
Data
subject
to
change
without
notice