Contactors and starters

xStart series contactors

xStart series
1.1

xStart series overload relays

Motor protective circuit breaker PKZ

xStart series overload relays
Bimetal relay ZE, ZB, Z5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overload relay ZW7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Electronic overload relays ZEB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
EMT6 thermistor overload relay for machine protection . . . . . . . . . . . . . . . . . . . . . . . . . . 4
C441 overload and monitoring relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

1.3

xStart series motor-protective circuit-breakers
Motor-protective circuit-breakers PKZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Motor-protective circuit-breakers PKE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
DC string circuit-breaker PKZ-SOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
DC switch-disconnectors P-SOL, SOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

1.4

Motor-starter combinations
Motor-starter combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

E Line thermal overload relay

1

E Line series

2.2

E Line contactors

1
1

1.2

2.1

Motor-starter combinations

xStart series contactors
Mini contactor relays, contactor relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors DIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

E Line contactors
Control relays XTRG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors XTCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
5

E Line thermal overload relay
Thermal overload relays XTOD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

2

1

Mini contactor relays,
contactor relay, contactors
Continual operation requires high operational reliability in the components used. The
DILM contactor achieves the best lifespan values in AC-3 applications and is ideal for
heavy AC-4 jogging.
Mini contactor relay DILE…,contactor relays, contactors up to 12 A AC-3 at 400 V
• Compact dimensions for the highest packing densities
• Extended performance range up to 5.5 kW at 400 V
AC and DC contactor system DILM…, contactor relays, 3 pole contactors up to 170 A AC-3
at 400 V, 4 pole contactors up to 200 A AC-1
•
•
•
•
•
•
•
•

Eaton after sales service
Testing switching devices in
compliance with regulations
applicable to this technology
See catalog

Easier engineering through identical construction sizes for AC- and DC-operated contactors
Energy savings and higher packing density in control panel due to minimized heat dissipation
High wiring security through doubled box terminals
Less coupler relays: direct actuation from the PLC for contactors up to 32 A
Easy engineering through integrated suppressor circuits for DC
Uniform accessories for 3- and 4-pole contactors
Mechanical interlock double conductor run mountable without additional separation gap
Direct fieldbus connection through the communication system SmartWire-DT®, through
plug-in type protective module

High rated contactors - contactors up to 1600 A AC-3 at 400 V, contactors up to 2600 A AC-1
•
•
•
•
•

Compact dimensions with high switching power
Direct actuation from the PLC saves coupler relays
Easy engineering through wide range coils
Cost and energy savings for control panel ventilation due to reduced heat dissipation
Long lifespan through vacuum technology from 580 A

SmartWire-DT®
The DIL product range offers contact elements which can be connected to the SmartWire-DT®
communication system.
Protective modules, Page 62
AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Mini contactors, relays, contactors
Contents

Ordering
Mini contactor relays DILER, DILEEM, DILEM
Mini contactor relays, contactors . . . . . . . . . . . . . . . .
Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Actuating voltages . . . . . . . . . . . . . . . . . . . . . . . . . . .
DILA contactor relays
Contactor relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . .
Actuating voltages . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
6
8
66
10
12
68

Technical overview
Contactors DILM, DILH . . . . . . . . . . . . . . . . . . . . . . . 14
System overview
Contactors DILM, DILH . . . . . . . . . . . . . . . . . . . . . . . 16
Ordering
Contactors DILM, DILH
Basic devices up to 170 A . . . . . . . . . . . . . . . . . . . . .
Complete units up to 170 A . . . . . . . . . . . . . . . . . . . .
Standard devices greater than 170 A . . . . . . . . . . . . .
Comfort devices greater than 170 A . . . . . . . . . . . . .
Basic devices up to 200 A, 4 pole . . . . . . . . . . . . . . .
Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . .

18
24
28
30
34
36

Engineering
Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . . 40
Ordering
DILK contactors for capacitors . . . . . . . . . . . . . . . . . . 41
Engineering
Contactors for power factor correction . . . . . . . . . . . 42
Ordering
Star-delta combinations SDAINL . . . . . . . . . . . . . . . . 44
Engineering
Star-delta combinations SDAINL . . . . . . . . . . . . . . . . 46
Ordering
DIUL reversing combinations . . . . . . . . . . . . . . . . . . . 48
Description
CMD contactor monitoring device . . . . . . . . . . . . . . . 64
Ordering
CMD contactor monitoring device . . . . . . . . . . . . . . . 64

Ordering
DILM contactor relays, DILM, DILH contactors
suppressor circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Ordering
Actuating voltages contactors DILM, DILH
Basic devices up to 170 A . . . . . . . . . . . . . . . . . . . .
Basic devices up to 200 A, 4 pole . . . . . . . . . . . . . .
Contactors up to 150 A
with electronic actuation . . . . . . . . . . . . . . . . . . . . .
Replacement coils . . . . . . . . . . . . . . . . . . . . . . . . . .
Comfort devices greater than 170 A . . . . . . . . . . . .
Standard devices greater than 170 A . . . . . . . . . . . .
Electronic modules including coil . . . . . . . . . . . . . . .
Contactors for capacitors . . . . . . . . . . . . . . . . . . . . .
Engineering
Contact travel diagrams . . . . . . . . . . . . . . . . . . . . . .
Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UL/CSA-approved rating data . . . . . . . . . . . . . . . . . .
UL/CSA special purpose ratings . . . . . . . . . . . . . . .
UL/CSA short circuit current rating . . . . . . . . . . . .
Contactors for resistive loads . . . . . . . . . . . . . . . . . .
Electrical life span . . . . . . . . . . . . . . . . . . . . . . . . . . .
Short-time loading . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating frequency . . . . . . . . . . . . . . . . . . . . . . . . .
Switching of DC current . . . . . . . . . . . . . . . . . . . . . .
Technical data
Mini contactor relays, contactor relays . . . . . . . . . . .
Contactor monitoring device . . . . . . . . . . . . . . . . . .
Basic devices up to 170 A . . . . . . . . . . . . . . . . . . . .
Basic devices up to 200 A, 4 pole . . . . . . . . . . . . . .
Comfort devices greater than 170 A . . . . . . . . . . . .
Standard devices greater than 170 A . . . . . . . . . . . .
Contactors for capacitors . . . . . . . . . . . . . . . . . . . . .
Contactors up to 150 A
with electronic actuation . . . . . . . . . . . . . . . . . . . . .
Lighting contactors . . . . . . . . . . . . . . . . . . . . . . . . . .
Auxiliary contact modules . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions
Mini contactor relays . . . . . . . . . . . . . . . . . . . . . . . .
Contactor relays . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Basic devices up to 170 A . . . . . . . . . . . . . . . . . . . .
Basic devices up to 200 A, 4 pole . . . . . . . . . . . . . .
Contactors larger than 170 A . . . . . . . . . . . . . . . . . .
Contactors for capacitors . . . . . . . . . . . . . . . . . . . . .
Lighting contactors . . . . . . . . . . . . . . . . . . . . . . . . . .
Contactor combinations . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

69
74
76
71
77
77
77
77

78
79
80
81
82
84
86
90
91
92

93
96
104
120
112
112
123
126
125
128
128

130
131
131
133
134
136
136
137
138

1

1

1.1
1

Contactors
Mini contactors, relays

Ordering

Screw terminals

DILER mini contactor relays
Rated operational current
AC-15
220 V
230 V
240 V

Conventional free
air thermal current

380 V
400 V
415 V

Ie

Ie

I th

A

A

A

6

3

10

Contact
N/O = normally open contact
NC = normally closed contact

4 N/O

–

Distinctive
number

Circuit symbol

40E

A1 13 23 33 43

For use with

DILE…

A2 14 24 34 44

3 N/O

1 NC

31E

A1 13 21 33 43

DILE…

A2 14 22 34 44

2 N/O

2 NC

22E

A1 13 21 31 43

DILE…

A2 14 22 32 44

Notes
Coil terminal marking as specified in EN 50005
Contact numbers to EN 50011
The following applies to DC-operated contactors:
• Integrated diode-resistor combination
• Coil rating 2.6 W

2

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL508; CSA-C22.2 No.14-05;
CE marking
E29184
NKCR
012528
3211-03
UL Listed,
CSA certified

Contactors
Mini contactors, relays

1.1
1

AC operation
Part no.
Article no.

DC operation
Price
See price list

Part no.
Article no.

DILER-40(230V50Hz)
051759

DILER-40-G(24VDC)
010223

DILER-31(230V50Hz)
051768

DILER-31-G(24VDC)
010157

DILER-22(230V50Hz)
051777

DILER-22-G(24VDC)
010042

Price
See price list

Std. pack

Notes

5 off

With screw terminals:
1

2

Accessories
1 Suppressor
2 Auxiliary contact modules
Further actuating voltages

Page
8
6
66

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

3

1.1

Contactors
Mini contactors, relays

DILEM contactors

1

3 pole with auxiliary
contact
Screw terminals

Rated
operational
current
AC-3

Max. motor rating for
three-phase motors, 50 - 60 Hz
AC-3

380 V
400 V
Ie

220 V
230 V
P

380 V
400 V
P

660 V
690 V
P

220 V
230 V
P

380 V
400 V
P

660 V
690 V
P

A

kW

kW

kW

kW

kW

kW

A

A

6.6

1.5

3

3

1.1

2.2

2.2

20

16

6.6

Circuit symbol

Open

Enclosed

I th = I e

I th = I e

N/O = normally open
contact
NC = normally
closed contact

3

3

1.1

2.2

2.2

20

1 N/O

16

–

–
1 NC

4

4

1.5

3

3

20

16

1 N/O

–

9

2.2

4

4

1.5

3

3

20

16

–

1 NC

9

3.5
3.5
2.2

5.5
5.5
4

6.5
6.5
4

2
2
1.5

3
3
3

2.2
2.2
3

20
20
20

16

1 N/O

16

–

16

–

–
1 NC
–

3

5 13

A2 2 4

6 14

A1 1

3

5

A2 2

4

6 22

A1 1

3

5 13

A2 2 4

6 14

A1 1

3

5

A2 2

4

6 22

A1 1

3

5 13

A2 2 4

6 14

A1 1

3

5

A2 2

4

6 22

A1 1

3

5 7

A2 2

4

6 8

A1 1

21

21

21

1)

2)

Information relevant for export to North America

Information relevant for export to North America

Product Standards

UL File No.
UL CC
CSA File No.
CSA Class No.
NA Certification

See also

For use with

AC-4

2.2

12

4

Contact

9

12

4 pole
Screw terminals

1.5

Conventional thermal
current I th = Ie
AC-1 at 50 °C

IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No.14-05; CE marking
E29096
NLDX
012528
3211-04
UL Listed, CSA certified
Page 80

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

…DILEM
DILE…
DILE…
…DILEM
DILE…
DILE…
…DILEM
DILE…
DILE…
…DILEM
DILE…

Product Standards IEC/EN 60947-4-1;
UL 508; CSA-C22.2 No.14-05; CE marking
E29096
UL File No.
NLDX
UL CCN
012528
CSA File No.
2411-03,3211-04
CSA Class No.
UL Listed, request filed for CSA
NA Certification

Contactors
Mini contactors, relays

1.1
1

AC operation
Part no.
Article no.

DC operation
Price
See price
list

Part no.
Article no.

DILEEM-10(230V50Hz) 1)
051608

DILEEM-10-G(24VDC)1)
051643

DILEEM-01(230V50Hz) 1)
051633

DILEEM-01-G(24VDC)1)
051650

DILEM-10(230V50Hz) 1)
051786

DILEM-10-G(24VDC)1)
010213

DILEM-01(230V50Hz) 1)
051795

DILEM-01-G(24VDC)1)
010343

DILEM12-10(230V50Hz) 2)
127075

DILEM12-10-G(24VDC) 2)
127132

DILEM12-01(230V50Hz) 2)
127091

DILEM12-01-G(24VDC) 2)
127137

DILEM4(230V50Hz) 1)
051804

DILEM4-G(24VDC)1)
012701

Price
See price
list

Std. pack

Notes

5 off

With screw terminals:
2

3

5 off

1

Accessories
1 Overload relay
2 Suppressor
3 Auxiliary contact module
Enclosures
Further actuating voltages
Accessories

Page
Chapter 1.2
8
6
66
8

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

5

1.1
1 Screw terminals

Mini contactor relays
Auxiliary contact modules

DILE
Auxiliary contact modules
Contact

Rated operational current

N/O = normally open
contact
S F = NO early-make
NC = normally closed
contact
Ö S = NC late-break

AC-15
220 V
230 V
240 V
Ie

Distinctive number/type of combinations
with basic device
DILER-40(-G)
DILER-31(-G)
DILER-22

A

A

A

–

–

2 NC

–

4

2

10

–

–

–

1 N/O

–

1 NC

–

4

2

10

–

–

–

4 pole

2 N/O

–

2 NC

–

4

2

10

–

–

–

2 pole

–

–

2 NC

–

4

2

10

42E

33

24

1 N/O

–

1 NC

–

4

2

10

51E

42

33

2 N/O

–

–

–

4

2

10

60E

51

42

–

1 SF

–

1 ÖS

4

2

10

51

42

33

–

–

4 NC

–

4

2

10

44E

35

26

1 N/O

–

3 NC

–

4

2

10

53E

44

35

2 N/O

–

2 NC

–

4

2

10

62E

53

44

3 N/O

–

1 NC

–

4

2

10

71E

62

53

4 N/O

–

–

–

4

2

10

80E

71

62

1 N/O

1 SF

1 NC

1 ÖS

4

2

10

62

53

44

2 pole

4 pole

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

6

380 V
400 V
415 V
Ie

Conventional
thermal current
I th

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05;
CE marking
E29184
NKCR
012528
3211-03
UL Listed,
CSA certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Mini contactor relays
Auxiliary contact modules

1.1
1

Circuit symbol

21 31

22 32
21 33

Can be combined with
contactor

Part no.
Article no.

DILEM-10(-G)(…)
DILEM-4(-G)(…)
DILEEM-10(-G)(…)
DILEM12-10(-G)(…)

02DILEM
010064

5 off

With interlocked
opposing contacts

11DILEM
010080

5 off

With interlocked
opposing contacts

22DILEM
010112

5 off

With interlocked
opposing contacts

02DILE
010240

5 off

With interlocked
opposing contacts

11DILE
010224

5 off

With interlocked
opposing contacts

20DILE
010208

5 off

With interlocked
opposing contacts

11DDILE
049824

5 off

–

04DILE
010256

5 off

With interlocked
opposing contacts

13DILE
002397

5 off

With interlocked
opposing contacts

22DILE
010288

5 off

With interlocked
opposing contacts

31DILE
048912

5 off

With interlocked
opposing contacts

40DILE
010304

5 off

With interlocked
opposing contacts

22DDILE
049823

5 off

–

22 34
21 31 43 53

Price
See price
list

Std. pack

22 32 44 54

DILEM-10(-G)(…)
DILEM-01(-G)(…)
DILEM-4(-G)(…)
DILER40(-G)
DILER31(-G)
DILER22
DILEEM-10(-G)(…)
DILEEM-01(-G)(…)
DILEM12-10(-G)(…)
DILEM12-01(-G)(…)

51 61

52 62
53 61

54 62
53 63

54 64
57 65

58 66
51 61 71 81

52 62 72 82
53 61 71 81

54 62 72 82
53 61 71 83

54 62 72 84

53 61 73 83

54 62 74 84
53 63 73 83

Notes

The following applies to ...DILEM auxiliary
contacts:
• Contacts to EN 50012
The following applies to ...DILE auxiliary contacts:
• Contacts to EN 50005
Contacts according to EN50012 are to be prefered.
Type E combinations compy with EN 50011 and are
to be given preference.
No interlocked opposing contacts in NO earlymakes and NC late-breaks.

54 64 74 84
57 65 71 83

58 66 72

84

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

7

1.1

Mini contactor relays
Accessories

1 VGDILE..., RCDILE..., MVDILE, BT480, P1DILEM
Actuating
voltage
Us

Circuit
symbol

For use with

Part no.
Article no.

DILE...

VGDILE48
010320
VGDILE250
010336
VGDILE415
010463

Price
See price
list

Std. pack

Information relevant for export to North America

10 off

Product Standards

V AC

Suppressor circuits
Varistor suppressor
24 - 48 AC

A1

110 - 250 AC
A2

380 - 415 AC

10 off
10 off

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E29096
NLDX
012528
3211-03
UL Listed, CSA certified

RC-Suppressor
24 - 48 AC

A1

DILE...

110 - 250 AC
A2

Notes

10 off

RCDILE48
044264
RCDILE250
046320

Product Standards

10 off
UL File No.
UL CCN
CSA File No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E29184
NKCR2
UL Recognized

For AC operated contactors 50 - 60 Hz.
DC operated contactor relays have an integrated suppressor.
Note drop-out delay.

VGDILE..., RCDILE..., MVDILE, BT480, P1DILEM
For use with

Part no.
Article no.

Price
See price
list

Std. pack

Information relevant for export to North America

V0DILE
026634

50 off

UL/CSA certification not required

MVDILE
010113

5 off

Product Standards

Mechanical interlocks
For mechanical connection of contactor and timing relays in
combinations.
0 mm distance between contactors.
DILE…
DILET…

Mechanical interlock
For contactors with the same or different magnet system.
0 mm distance between contactors.
Mechanical lifespan 2.5 x 106 operations.
Additional auxiliary contact modules possible.
–

DILE…

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E29184
NKCR2
012528
3211-07
UL Recognized, CSA certified

Paralleling link
For parallel connection of contacts
–

DILE…
DILE…

BT480 1)
052785

100 off

Consisting of two four-pole paralleling links.
DILEEM
DILEM12
DILEM
Notes

1)
2)

8

P1DILEM 2)
019095

5 off

Not protected against accidental contact as specified in VDE 0106 Part 100.
4th pole can be broken off
4 pole: Ith = 60 A open
3 pole: Ith = 50 A open
AC-1 current carrying capacity of the open contactor increases by a factor of 2.5
Protected against accidental contact in accordance with VDE 0106 Part 100

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E29096
NLDX
012528
3211-07
UL Listed, CSA certified

Mini contactor relays
Accessories

1.1

HDILE, ...DILEM, MVS
Contact
sequence

1
For use with

Part no.
Article no.

Price
See price
list

Std. pack

Information relevant for export to North America

HDILE
010482

1 off

UL/CSA certification not required

S1DILEM 1)
220218

20 off

MVS-WB-EM 2)
220209

1 off

Sealable shrouds
Transparent
Snap-fitting on contactor.
Can be used with open installation or on service distribution board.
Protection type: IP40 front
Can be drilled to accommodate timing relay setting dials.
DILE…
DILET…

Start-point bridge
DILEEM
DILEM12
DILEM

Reversing starter wiring kit
Main current wiring for reversing combinations
DILEEM (+MVDILEM)
DILEM12 (+MVDILEM)
DILEM (+MVDILEM)

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E36332
NLRV7
012528
3211-06
UL Listed, CSA certified

Star-delta wiring kit
Main current wiring for star-delta combination incl. star-point bridge
DILE(E)M (+MVDILEM)
DILE(E)M12 (+MVDILEM)
DILE(E)M star contactor

MVS-SB-EM 3)
220213

1 off

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

Notes

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E36332
NLRV7
012528
3211-06
UL Listed, CSA certified

1)

Protected against accidental contact in accordance with VDE 0106 Part 100
The following control cables are integrated in addition to electrical interlock:
• Q11: A1 -Q12: 21
• Q11: 21 - Q12: A1
• Q11: A2 - Q12: A2
For use with overload relay separate mounting.
3) The following control cables are integrated in addition to electrical interlock:
• Q13: A1 -Q15: 21
• Q13: 21 - Q15: A1
• Q13: A2 - Q15: A2
For use with overload relay separate mounting.
2)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

9

1.1

Contactor relays
Basic devices

DILA
Basic devices with positively driven contacts

1

Contact
N/O = normally
open contact

Rated operational current
NC = normally
closed contact

A C - 15
220 V
230 V
240 V
Ie

Screw terminals

4 N/O

–

3 N/O

1 NC

380 V
400 V
415 V
Ie

A

A

4

4

Distinctive
number

Can be combined
with auxiliary contact

16

40E

DILA-XHI(V)…

A1 13 23 33 43

16

31E

DILA-XHI(V)…

A1 13 21 33 43

Conventional
thermal current
I th

Circuit symbol

A

A2 14 24 34 44

4

4

A2 14 22 34 44

2 N/O

2 NC

4

4

16

22E

DILA-XHI(V)…

A1 13 21 31 43

A2 14 22 32 44

Spring-loaded
terminals

4 N/O

–

4

4

16

40E

DILA-XHIC(V)…

A1 13 23 33 43

3 N/O

1 NC

4

4

16

31E

DILA-XHIC(V)…

A1 13 21 33 43

A2 14 24 34 44

A2 14 22 34 44

2 N/O

2 NC

4

4

16

22E

DILA-XHIC(V)…

A1 13 21 31 43

A2 14 22 32 44

Notes

10

Contact numbers to EN 50011
Coil terminal markings to EN 50005
The following applies to DC-operated contactors:
• Integrated suppressor circuit

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29184
NKCR
012528
3211-03
UL Listed, CSA certified

Contactor relays
Basic devices

1.1
1

AC operation
Part no.
Article no.

DILA-40(230V50Hz)
276329

DC operation
Price
See price
list

Std. pack

1 off

Circuit symbol

A1 13 23 33 43

Part no.
Article no.

Price
See price
list

DILA-40(24VDC)
276344

Std. pack

Notes

1 off

With screw terminals:

A2 14 24 34 44

DILA-31(230V50Hz)
276364

1 off

DILA-22(230V50Hz)
276399

1 off

A1 13

21 33 43

A2 14 22 34 44

A1 13 21 31 43

A2 14 22 32 44

DILA-31(24VDC)
276379
DILA-22(24VDC)
276414

2

1
Accessories
1 Suppressor
2 Auxiliary contact modules
Further actuating voltages
DILAC-40(230V50Hz)
276441

1 off

A1 13 23 33 43

DILAC-40(24VDC)
276456

1 off

Page
50
36
68

With spring-loaded terminals:

A2 14 24 34 44

DILAC-31(230V50Hz)
276473

1 off

DILAC-22(230V50Hz)
276505

1 off

A1 13

21 33 43

A2 14 22 34 44

A1 13 21 31 43

A2 14 22 32 44

DILAC-31(24VDC)
276488
DILAC-22(24VDC)
276520

2

1
Accessories
1 Suppressor
2 Auxiliary contact modules
Further actuating voltages

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Page
50
36
68

11

1.1

Contactor relays
Auxiliary contact modules

DILA...XHI...
DILA auxiliary contact modules

1

Screw terminals

2 pole

Contact

Rated operational current

Conventional
thermal current

N/O = normally open contact
S F = NO early-make
NC = normally closed contact
Ö S = NC late-break

AC-15
220 V
230 V
240 V
Ie
A

380 V
400 V
415 V
Ie
A

I th

Circuit symbol

A

–

–

2 NC

–

4

4

16

1 N/O

–

1 NC

–

4

4

16

2 N/O

–

–

–

4

4

16

–

1 SF

51 61

52 62
53 61

54 62
53 63

54 64

–

1 ÖS

4

4

16

57 65

58 66

4 pole

Screw terminals

–

–

4 NC

–

4

4

16

51 61 71 81

52 62 72 82

1 N/O

–

3 NC

–

4

4

16

2 N/O

–

2 NC

–

4

4

16

53 61 71 83

3 N/O

–

1 NC

–

4

4

16

53 61 73 83

4 N/O

–

–

–

4

4

16

53 63 73 83

1 N/O

1 SF

1 NC

1 ÖS

4

4

16

–

–

2 NC

–

4

4

16

1 N/O

–

1 NC

–

4

4

16

2 N/O

–

–

–

4

4

16

–

1 SF

–

1 ÖS

4

4

16

53 61 71 81

54 62 72 82

54 62 72 84

54 62 74 84

54 64 74 84
57 65 71 83

58 66 72

Spring-loaded terminals

2 pole

84

51 61

52 62
53 61

54 62
53 63

54 64
57 65

58 66

Spring-loaded terminals

4 pole

–

–

4 NC

–

4

4

16

51 61 71 81

52 62 72 82

1 N/O

–

3 NC

–

4

4

16

53 61 71 81

54 62 72 82

2 N/O

–

2 NC

–

4

4

16

53 61 71 83

54 62 72 84

3 N/O

–

1 NC

–

4

4

16

53 61 73 83

4 N/O

–

–

–

4

4

16

53 63 73 83

1 N/O

1 SF

1 NC

1 ÖS

4

4

16

54 62 74 84

54 64 74 84
57 65 71 83

58 66 72

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

12

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29184
NKCR
012528
3211-03
UL Listed, CSA certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

84

Contactor relays
Auxiliary contact modules

1.1
1

Distinctive number/type
of combinations
DILA(C)-40
DILA(C)-31

Part no.
Article no.
DILA(C)-22

42E

33

24

51E

42

60E

Price
See price list

Std. pack

Description

Notes

DILA-XHI02
276420

5 off

With interlocked
opposing contacts

33

DILA-XHI11
276421

5 off

With interlocked
opposing contacts

51

42

DILA-XHI20
276422

5 off

With interlocked
opposing contacts

Type E combinations comply with
EN 50011 and must be given preference.
The other combinations comply with
EN 50005
The DC operated contactor DILA(C)-22 must only
be combined with 2 pole auxiliary contacts.

51

42

33

DILA-XHIV11
276423

5 off

–

44E

35

26

DILA-XHI04
276424

5 off

With interlocked
opposing contacts

53E

44

35

DILA-XHI13
276425

5 off

With interlocked
opposing contacts

62E

53

44

DILA-XHI22
276426

5 off

With interlocked
opposing contacts

71E

62

53

DILA-XHI31
276427

5 off

With interlocked
opposing contacts

80E

71

62

DILA-XHI40
276428

5 off

With interlocked
opposing contacts

62

53

44

DILA-XHIV22
276429

5 off

–

42E

33

24

DILA-XHIC02
276526

5 off

With interlocked
opposing contacts

51E

42

33

DILA-XHIC11
276527

5 off

With interlocked
opposing contacts

60E

51

42

DILA-XHIC20
276528

5 off

With interlocked
opposing contacts

51

42

33

DILA-XHICV11
276529

5 off

–

44E

35

26

DILA-XHIC04
276530

5 off

With interlocked
opposing contacts

53E

44

35

DILA-XHIC13
276531

5 off

With interlocked
opposing contacts

62E

53

44

DILA-XHIC22
276532

5 off

With interlocked
opposing contacts

71E

62

53

DILA-XHIC31
276533

5 off

With interlocked
opposing contacts

80E

71

62

DILA-XHIC40
276534

5 off

With interlocked
opposing contacts

62

53

44

DILA-XHICV22
276535

5 off

–

Type E combinations comply with
EN 50011 and must be given preference.
The other combinations comply with
EN 50005
The DC operated contactor DILA(C)-22 must only
be combined with 2 pole auxiliary contacts.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

13

1.1
1

Contactors

Technical overview
DILM, DILE(E)M, DILMP
Contactors
3 pole

DIL
Basic devices

Page

EEM

Complete units

Page

Rated-operational voltage
AC-3
Rated operational power
for 3-phase motors 50 –60 Hz
220 V – 230 V
380 V – 400 V
440 V
500 V
660 V/690 V
1000 V

EM

EM12 M7

4

M9

M12 M15 M17

18

–

Page 24

M25

M32

M38

M40

M50 M65

M80

M95

18

20

46

Page 24

Page 26

Page 26

–

M115 M150 M170

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

1.5
3
3.3
3
3
–

2.2
4
4.6
4
4
–

3
5.5
5.5
5.5
4
–

2.2
3
4.5
3.5
3.5
–

2.5
4
5.5
4.5
4.5
–

3.5
5.5
7.5
7
6.5
–

4
7.5
8.4
7.5
7
–

5
7.5
10.5
12
11
–

7.5
11
15.5
17.5
14
–

10
15
20
23
17
–

11
18.5
21
24
21
–

12.5
18.5
25
28
23
–

15.5
22
32
36
30
–

20
30
41
47
35
–

25
37
51
58
63
–

30
45
60
70
75
–

37
55
75
85
90
–

48
75
95
110
96
–

52
90
105
120
140
–

AC-4
Rated operational power
for 3-phase motors 50 –60 Hz
220 V – 230 V
1.1
380 V – 400 V
2.2
440 V
2.4

Increase in life span for DILM7 – DILM150 to 200000 operations

1.5
3
3.3

1.5
3
3.3

1
2.2
2.4

1.5
2.5
3

2
3
3.6

2
3
3.6

2.5
4.5
5.5

3.5
6
7

4
7
8

4
7
8

5
9
10

6
10
12

7
12
14

12
20
25

16
26
32

17
28
35

20
33
41

20
33
41

500 V
2.2
3
3
660 V/690 V
2.2
3
3
1000 V
–
–
–
AC-1
Rated operational power under resistive load, 40 °C

2.5
2.9
–

2.8
3.6
–

3.5
4.4
–

3.5
4.4
–

6
6.5
–

8
8.5
–

9
10
–

9
10
–

11
12
–

13
14
–

16
17
–

29
26
–

36
35
–

40
43
–

47
48
–

47
48
–

220 V – 230 V
380 V – 400 V
400 V

8
13
15

8
13
15

8
13
15

8
14
16

8
14
16

8
14
16

8
14
16

15
26
30

17
29
34

17
29
34

17
29
34

22
39
45

30
53
58

37
65
71

42
72
80

49
85
94

61
105
116

72
125
138

85
150
170

500 V
660 V/690 V
1000 V
Conventional thermal
Current
I th = I e open at 40 °C

18
23
–

18
23
–

18
23
–

19
25
–

19
25
–

19
25
–

19
25
–

34
45
–

38
51
–

38
51
–

38
51
–

51
68
–

66
91
–

81
111
–

90
125
–

107
148
–

132
182
–

156
216
–

194
268
–

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

22

22

22

22

22

22

22

40

45

45

45

60

80

98

110

130

160

190

225

DILM, DILE(E)M, DILMP
Contactors
4 pole

Rated operational voltage

DIL
Page

AC-1
Conventional free air thermal current Ith = Ie open, at 40 °C
up to 690 V
14

EM4
4

MP20
Page 34

MP32
Page 34

A

A

A

22

22

32

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors

1

DILM, DILH, DILMP
Contactors
3 pole

M185A M225A
–
–
Page 30

M250A
–

M300A M400
–
–
Page 30

M500
–

M580
M650
–
–
Page 30

M750
M820
–
–
Page 30

M1000
–

M1600
M1400
–
–
Page 32

H2000
–

H2200
–

H2600
–

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

kW

55
90
115
132

70
110
142
160

75
132
157
180

90
160
190
215

125
200
255
290

155
250
345
360

185
315
370
420

205
355
420
470

240
400
480
550

260
450
525
600

315
560
650
730

500
900
1000
1180

–
–
–
–

–
–
–
–

–
–
–
–

–
–
–
–

175
108

215
108

240
108

286
132

344
132

344
132

560
600

630
600

720
800

750
800

1000
1000

1600
1770

–
–

–
–

–
–

–
–

41
75
85

51
90
102

62
110
125

75
132
140

92
160
186

112
200
229

143
250
290

161
280
326

181
315
367

209
355
418

260
450
520

430
750
830

–
–
–

–
–
–

–
–
–

–
–
–

96
127
108

116
155
108

143
189
108

172
229
132

214
283
132

260
344
132

330
440
509

370
494
509

417
556
678

474
633
678

590
780
1000

940
1300
1650

–
–
–

–
–
–

–
–
–

–
–
–

121
210
243

139
241
279

155
268
310

177
306
354

221
382
443

310
535
620

354
612
709

376
650
753

398
689
797

443
766
886

443
766
886

717
1247
1371

620
1071
1240

886
1531
1773

1075
1870
2058

1269
2207
2427

277
365
554

317
419
635

352
465
705

403
532
806

503
664
1007

705
930
1410

806
1064
1612

856
1130
1712

906
1196
1813

1007
1330
2015

1007
1330
2015

1558
2151
2420

1410
1861
2417

2015
2660
3223

2338
3227
4676

2758
3806
5516

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

337

356

400

430

612

857

980

1041

1102

1225

1225

2200

1714

2450

2700

3185

DILM, DILE(E)M, DILMP
Contactors
4 pole

MP45
Page 34

MP63
Page 34

MP80

MP125
Page 34

MP160

MP200

A
45

A
63

A
80

A
125

A
160

A
200

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

15

1.1
1

Contactors

System overview
8
6

DILM7...DILM170
6

1

1

Contactors up to 90 kW
(AC-3/400V)

1

3 pole
Page 18
4 pole
Page 34
Suppressor circuits

2

Page 50
2 T1 4 T2
6 T3

Overload relays

3

Chapter 1.2 (Page 8)
7

Auxiliary contact modules

9
2

57

4

Page 36
3

NO

Auxiliary contact modules

58

5

Range (s)

1

65

10

Page 36

100

NC

66

Time

Auxiliary contact modules

5

5

6

Page 39

4

10

Motor feeder plug
6

6

7

Page 58
PE module with contact
plate

8

Page 58
1

1

Motor suppressor module

9

Page 59
SmartWire-DT®
contactor module
Page 58

3
3

2
3

4

16

5

5

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

10

Contactors

1.1
1

1

5

2

4

3

DILM185... DILH2600
Contactors 90 – 900 kW
(AC-3/400 V)
Comfort series
Page 30
Standard range 90–250kW
Page 28

1

1

Mechanical interlock
Page 52

2

Terminal shroud
Page 61

4

Overload relays

3

Auxiliary contact modules

5

Chapter 1.2 (Page 12)

Page 39

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

17

1.1

Contactors
Basic devices up to 170 A

DILM
Basic device

1

Screw terminals
3 pole

Rated operational
current

Max. motor rating for
three-phase motors 50 - 60 Hz

AC-3

AC-3

380 V
400 V

220 V
230 V

AC-4
380 V
400 V

660 V
690 V

220 V
230 V

380 V
400 V

660 V
690 V

Open

Circuit symbol

N/O = normally open
contact
NC = normally closed
contact

Ie

P

P

P

P

P

P

Ith = Ie

kW

kW

kW

kW

kW

kW

A

7

2.2

3

3.5

1

2.2

2.9

20

1 N/O

–

7

2.2

3

3.5

1

2.2

2.9

20

–

1 NC

3

5 13

A2 2 4

6 14

A1 1

3

5

A2 2

4

6 22

A1 1

3

5 13

A1 1

21

9

2.5

4

4.5

1.5

2.5

3.6

20

1 N/O

–

A2 2 4

6 14

9

2.5

4

4.5

1.5

2.5

3.6

20

–

1 NC

A1 1

5

A2 2

4

6 22

12

3.5

5.5

6.5

2

3

4.4

20

1 N/O

–

A1 1

3

5 13

A2 2 4

6 14

12

3.5

5.5

6.5

2

3

4.4

20

–

1 NC

A1 1

5

A2 2

4

6 22

15.5

4

7.5

7

2

3

4.4

20

1 N/O

–

A1 1

3

5 13

A2 2 4

6 14

A1 1

3

5

A2 2

4

6 22

A1 1

18

18
25

4
5

5
7.5

7.5
7.5

7.5
11

7
11

11
14

2
2.5

2.5
3.5

3
4.5

4.5
6

4.4
6.5

6.5
8.5

20
35

35
40

–
1 N/O

–
1 N/O

1 NC
–

1 NC
–

3

3

21

21

21

3

5 13

A2 2 4

6 14

A1 1

3

5

A2 2

4

6 22

A1 1

3

5 13

A2 2 4

6 14

5

21

25

7.5

11

14

3.5

6

8.5

40

–

1 NC

A1 1

A2 2

4

6 22

32

10

15

17

4

7

10

40

1 N/O

–

A1 1

3

5 13

A2 2 4

6 14

5

3

21

32

10

15

17

4

7

10

40

–

1 NC

A1 1

A2 2

4

6 22

38

11

18.5

21

4

7

10

40

1 N/O

–

A1 1

3

5 13

A2 2 4

6 14

A1 1

3

5

A2 2

4

6 22

38

11

18.5

21

4

7

10

40

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
See also

18

Contact configuration

A

15.5
Screw terminals
3 pole

Conventional thermal
current I th = Ie AC-1
at 60 °C

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
012528
2411-03, 3211-04
UL Listed,
CSA certified
Page 80

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

–

1 NC

3

21

21

Contactors
Basic devices up to 170 A

1.1
1

AC operation

DC operation

Can be combined
with auxiliary
contact

Part no.
Article no.

DILM32-XHI..
DILA-XHI(V)..

DILM7-10(230V50Hz)
276550

DILM7-10(24VDC)
276565

DILA-XHI(V)..

DILM7-01(230V50Hz)
276585

DILM7-01(24VDC)
276600

DILM32-XHI..
DILA-XHI(V)..

DILM9-10(230V50Hz)
276690

DILM9-10(24VDC)
276705

DILA-XHI(V)..

DILM9-01(230V50Hz)
276725

DILM9-01(24VDC)
276740

DILM32-XHI..
DILA-XHI(V)..

DILM12-10(230V50Hz)
276830

DILM12-10(24VDC)
276845

DILA-XHI(V)..

DILM12-01(230V50Hz)
276865

DILM12-01(24VDC)
276880

DILM32-XHI..
DILA-XHI(V)..

DILM15-10(230V50Hz) 1)
290058

DILM15-10(24VDC)1)
290073

DILA-XHI(V)..

DILM15-01(230V50Hz) 1)
290093

DILM15-01(24VDC)1)
290108

DILM32-XHI..
DILA-XHI(V)..
DILM32-XHI11-S

DILM17-10(230V50Hz)
277004

DILM17-10(RDC24)
277018

DILA-XHI(V)..
DILM32-XHI11-S

DILM17-01(230V50Hz)
277036

DILM17-01(RDC24)
277050

DILM32-XHI..
DILA-XHI(V)..
DILM32-XHI11-S
DILA-XHI(V)..
DILM32-XHI11-S

DILM25-10(230V50Hz)
277132

DILM25-10(RDC24)
277146

DILM25-01(230V50Hz)
277164

DILM25-01(RDC24)
277178

DILM32-10(230V50Hz)
277260

DILM32-10(RDC24)
277274

DILM32-01(230V50Hz)
277292

DILM32-01(RDC24)
277306

DILM38-10(230V50Hz) 1)
112428

DILM38-10(RDC24)1)
112442

DILM38-01(230V50Hz) 1)
112456

DILM38-01(RDC24)1)
112470

DILM32-XHI..
DILA-XHI(V)..
DILM32-XHI11-S
DILA-XHI(V)..
DILM32-XHI11-S
DILM32-XHI..
DILA-XHI(V)..
DILM32-XHI11-S
DILA-XHI(V)..
DILM32-XHI11-S

Price
See
price list

Part no.
Article no.

Price
See
price list

Std. pack

Notes

1 off

Contacts to EN 50 012.
For all DC operated contactors DILM7 - DILM15 the following
applies:
• Integrated varistor-suppressor circuit.
For DC operated contactors DILM17 - DILM170 the following
applies:
• Integrated suppressor circuit in actuating electronics
For AC operated contactors DILM115 - DILM170 the following
applies:
• Integrated suppressor circuit in actuating electronics
For DILM7-01 – DILM38-01 the following applies:
• With mirror contact.
1) Electrical

lifespan

87

3

2

Accessories
1 Overload relay
2 Suppressor
3 Auxiliary contact module
Further actuating voltages
Accessories

1

Page
Chapter 1.2
50
36
69
52

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

19

1.1

Contactors
Basic devices up to 170 A

DILM
Basic device

1

Screw terminals
3 pole

Rated operational
current

Max. motor rating for
three-phase motors 50 - 60 Hz

AC-3

AC-3

380 V
400 V

220 V
230 V

AC-4
380 V
400 V

660 V
690 V

220 V
230 V

380 V
400 V

660 V
690 V

Open

Ie

P

P

P

P

P

P

Ith = Ie

A

kW

kW

kW

kW

kW

kW

A

40

12.5

18.5

23

5

9

12

50

50

65

72

Screw terminals
3 pole

Conventional thermal
current I th = Ie AC-1
at 60 °C

80

95

115

150

170

15.5

20

25

25

30

37

48

52

22

30

37

37

45

55

75

90

30

35

35

63

75

90

96

140

6

7

7

12

16

17

20

20

10

12

12

20

26

28

33

33

14

17

17

26

35

43

48

48

65

80

80

90

110

130

160

185

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
See also

20

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
012528
2411-03, 3211-04
UL Listed,
CSA certified
Page 80

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Contact configuration

Circuit
symbol

N/O = normally open
contact
NC = normally closed
contact

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

Contactors
Basic devices up to 170 A

1.1
1

AC operation

DC operation

Can be combined
with auxiliary
contact

Part no.
Article no.

Price
See
price list

Part no.
Article no.

DILM150-XHI(V)..
DILM1000XHI(V)..
DILM150-XHI(V)..
DILM1000XHI(V)..
DILM150-XHI(V)..
DILM1000XHI(V)..
DILM150-XHI(V)..
DILM1000XHI(V)..
DILM150-XHI(V)..
DILM1000XHI(V)..

DILM40(230V50Hz)
277766

DILM40(RDC24)
277780

DILM50(230V50Hz)
277830

DILM50(RDC24)
277844

DILM65(230V50Hz)
277894

DILM65(RDC24)
277908

DILM72(230V50Hz) 1)
107670

DILM72(RDC24)1)
107671

DILM80(230V50Hz)
239402

DILM80(RDC24)
239416

DILM150-XHI(V)..
DILM1000XHI(V)..

DILM95(230V50Hz)
239480

DILM95(RDC24)
239510

DILM150-XHI(V)..
DILM1000XHI(V)..
DILM150-XHI(V)..
DILM1000XHI(V)..
DILM150-XHI(V)..
DILM1000XHI(V)..

DILM115(RAC240)
239548

DILM115(RDC24)
239555

DILM150(RAC240)
239588

DILM150(RDC24)
239591

DILM170(RAC240)1)
107013

DILM170(RDC24)1)
107016

Price
See
price list

Std. pack

Notes

1 off

Contacts to EN 50012.
For all DC operated contactors DILM7 - DILM15 the following
applies:
• Integrated varistor-suppressor circuit.
For DC operated contactors DILM17 - DILM170 the following
applies:
• Integrated suppressor circuit in actuating electronics
For AC operated contactors DILM115 - DILM170 the following
applies:
• Integrated suppressor circuit in actuating electronics
For DILM7-01 – DILM38-01 the following applies:
• With mirror contact.
1) Electrical

lifespan

87

3

2

Accessories
1 Overload relay
2 Suppressor
3 Auxiliary contact module
Further actuating voltages
Accessories

1

Page
Chapter 1.2
50
36
71
52

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

21

1.1

Contactors
Basic devices up to 170 A

DILM
Basic device

1

Spring-loaded terminals
3 pole

Rated operational
current

Max. motor rating for
three-phase motors 50 - 60 Hz

AC-3
380 V
400 V
Ie
A

AC-3
220 V
230 V
P
kW

380 V
400 V
P
kW

660 V
690 V
P
kW

AC-4
220 V
230 V
P
kW

380 V
400 V
P
kW

660 V
690 V
P
kW

I th = Ie
A

7

2.2

3

3.5

1

2.2

2.9

20

7
9
9
12

Spring-loaded terminals on
auxiliary and control circuit
terminals
3 pole

2.2
2.5
2.5
3.5

3
4
4
5.5

3.5
4.5
4.5
6.5

1
1.5
1.5
2

Conventional thermal
current Ith = Ie AC-1
at 60 °C

2.2
2.5
2.5
3

2.9
3.6
3.6
4.4

Open

20
20
20
20

Circuit symbol

N/O = normally open
contact
NC = normally closed
contact

1 N/O
–
1 N/O
–
1 N/O

–
1 NC
–
1 NC
–

3

5 13

A2 2 4

6 14

A1 1

3

5

A2 2

4

6 22

A1 1

A1 1

21

3

5 13

A2 2 4

6 14

A1 1

3

5

A2 2

4

6 22

A1 1

21

3

5 13

A2 2 4

6 14
5

12

3.5

5.5

6.5

2

3

4.4

20

–

1 NC

A1 1

A2 2

4

6 22

15.5

4

7.5

7

2

3

4.4

20

1 N/O

–

A1 1

3

5 13

A2 2 4

6 14

15.5

4

7.5

7

2

3

4.4

20

–

1 NC

A1 1

5

A2 2

4

6 22

18

5

7.5

11

2.5

4.5

6.5

35

1 N/O

–

A1 1

3

5 13

A2 2 4

6 14

18

5

7.5

11

2.5

4.5

6.5

35

–

1 NC

A1 1

3

5

A2 2

4

6 22

A1 1

25
25

7.5
7.5

11
11

14
14

3.5
3.5

6
6

8.5
8.5

40
40

1 N/O
–

–
1 NC

32

10

15

7

10

40

1 N/O

–

32

10

15

7

10

40

–

1 NC

40

12.5

18.5

9

12

50

–

–

50

15.5

22

10

14

65

–

–

65

20

30

12

17

80

–

–

80

25

37

63

12

20

26

90

–

–

95

30

45

75

16

26

35

110

–

–

115

37

55

90

17

28

43

130

–

–

150

48

75

96

20

33

48

160

–

–

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
See also
22

Contact configuration

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
012528
2411-03, 3211-04
UL Listed, CSA certified
Page 80

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

3

3

21

21

21

3

5 13

A2 2 4

6 14

A1 1

3

5

A2 2

4

6 22

A1 1

3

5 13

A2 2 4

6 14

A1 1

3

5

A2 2

4

6 22

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

A1 1

3

5

A2 2

4

6

21

21

Contactors
Basic devices up to 170 A

1.1
1

Can be combined
with auxiliary
contact

AC operation
Part no.
Article no.

DC operation
Price
See
price list

Part no.
Article no.

DILM32-XHIC..
DILA-XHIC(V)..

DILMC7-10(230V50Hz)
277389

DILMC7-10(24VDC)
277404

DILA-XHIC(V)..

DILMC7-01(230V50Hz)
277421

DILMC7-01(24VDC)
277436

DILM32-XHIC..
DILA-XHIC(V)..

DILMC9-10(230V50Hz)
277453

DILMC9-10(24VDC)
277468

DILA-XHIC(V)..

DILMC9-01(230V50Hz)
277485

DILMC9-01(24VDC)
277500

DILM32-XHIC..
DILA-XHIC(V)..

DILMC12-10(230V50Hz)
277517

DILMC12-10(24VDC)
277532

DILA-XHIC(V)..

DILMC12-01(230V50Hz)
277549

DILMC12-01(24VDC)
277564

DILM32-XHIC…
DILA-XHIC(V)…

DILMC15-10(230V50Hz)
293911

DILMC15-10(24VDC)
293926

DILA-XHIC(V)…

DILMC15-01(230V50Hz)
293946

DILMC15-01(24VDC)
293961

DILM32-XHIC..
DILA-XHIC(V)..

DILMC17-10(230V50Hz)
277581

DILMC17-10(RDC24)
277595

DILA-XHIC(V)..

DILMC17-01(230V50Hz)
277611

DILMC17-01(RDC24)
277625

DILM32-XHIC..
DILA-XHIC(V)..

DILMC25-10(230V50Hz)
277641

DILMC25-10(RDC24)
277655

DILA-XHIC(V)..

DILMC25-01(230V50Hz)
277671

DILMC25-01(RDC24)
277685

DILM32-XHIC..
DILA-XHIC(V)..

DILMC32-10(230V50Hz)
277701

DILMC32-10(RDC24)
277715

DILA-XHIC(V)..

DILMC32-01(230V50Hz)
277731

DILMC32-01(RDC24)
277745

DILM150XHIC(V)..
DILM1000-XHIC..

DILMC40(230V50Hz)
277965

DILMC40(RDC24)
277979

DILMC50(230V50Hz)
277995

DILMC50(RDC24)
278009

DILMC65(230V50Hz)
278025

DILMC65(RDC24)
278039

DILMC80(230V50Hz)
239618

DILMC80(RDC24)
239652

DILMC95(230V50Hz)
239685

DILMC95(RDC24)
239715

DILMC115(RAC240)
239736

DILMC115(RDC24)
239741

DILMC150(RAC240)
239751

DILMC150(RDC24)
239765

Std. pack

Notes

1 off

Contacts to EN 50 012.
For DILMC7 – DILMC15 the following applies:
• Auxiliary coil, and main current terminals with spring-loaded
terminals.
For DILMC17 – DILMC150 the following applies:
• Auxiliary connections, coil connections with spring-loaded
connection terminals.
• Main current connections with screw terminals.
For DC operated contactors DILMC7 - DILMC15 the following
applies:
• Integrated varistor-suppressor circuit.
For DC operated contactors DILMC17 - DILMC150 the following
applies:
• Integrated suppressor circuit in actuating electronics
For AC operated contactors DILMC115 - DILMC150 the
following applies:
• Integrated suppressor circuit in actuating electronics
For DILMC7-01 – DILMC32-01 the following applies:
• With mirror contact.

Price
See
price list

3

2

1

Accessories
1 Overload relay
2 Suppressor
3 Auxiliary contact module
Further actuating voltages
Accessories

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Page
Chapter 1.2
50
36
73
52

23

1.1

Contactors
Complete device up to 170 A

DILM complete device

1

Screw terminals

Screw terminals

Rated operational current
AC-3

Max. motor rating for
three-phase motors 50 - 60 Hz
AC-3
AC-4

Conventional
free air
thermal
current I th = Ie
AC-1 at 60 °C

380 V
400 V

220 V
230 V

380 V
400 V

660 V
690 V

220 V
230 V

380 V
400 V

660 V
690 V

Ie

P

P

P

P

P

P

Open
Ith = Ie

A

kW

kW

kW

kW

kW

kW

A

7

2.2

3

3.5

1

2.2

2.9

7

2.2

3

3.5

1

2.2

7

2.2

3

3.5

1

9

2.5

4

4.5

9

2.5

4

9

2.5

12
12

Circuit symbol

Contact configuration:
= Safety function by
positive opening according
to IEC/EN 60947-5-1
N/O = normally
open contact

NC = normally
closed contact

20

2 N/O

1 NC

2.9

20

2 N/O

1 NC

A2 2 4

6 14 22 32 44

2.2

2.9

20

3 N/O

2 NC

A1 1

5 13 21 31 43 53

1.5

2.5

3.6

20

2 N/O

1 NC

4.5

1.5

2.5

3.6

20

2 N/O

1 NC

A2 2 4

6 14 22 32 44

4

4.5

1.5

2.5

3.6

20

3 N/O

2 NC

A1 1

5 13 21 31 43 53

3.5

5.5

6.5

2

3

4.4

20

2 N/O

1 NC

3.5

5.5

6.5

2

3

4.4

20

2 N/O

1 NC

12

3.5

5.5

6.5

2

3

4.4

20

3 N/O

2 NC

15.5

4

7.5

7

2

3

4.4

20

2 N/O

2 NC

18
18
18
25
25

5
5
5
7.5
7.5

7.5
7.5
7.5
11
11

11
11
11
14
14

2.5
2.5
2.5
3.5
3.5

4.5
4.5
4.5
6
6

6.5
6.5
6.5
8.5
8.5

35
35
35
40
40

2 N/O
2 N/O
3 N/O
2 N/O
2 N/O

1 NC
1 NC
2 NC
1 NC
1 NC

A1 1

3

5 13 21 33

A2 2 4

6 14 22 34

A1 1

5 13 21 31 43

3

3

A2 2 4

6 14 22 32 44 54

A1 1

3

5 13 21 33

A2 2 4

6 14 22 34

A1 1

5 13 21 31 43

3

3

A2 2 4

6 14 22 32 44 54

A1 1

3

5 13 21 33

A2 2 4

6 14 22 34

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44

A1 1

3

5 13 21 31 43 53

A2 2 4

6 14 22 32 44 54

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44

A1 1

3

5 13 21 33

A2 2 4

6 14 22 34

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44

A1 1

5 13 21 31 43 53

3

A2 2 4

6 14 22 32 44 54

A1 1

3

5 13 21 33

A2 2 4

6 14 22 34

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44

A1 1

5 13 21 31 43 53

3

25

7.5

11

14

3.5

6

8.5

40

3 N/O

2 NC

32

10

15

17

4

7

10

40

2 N/O

1 NC

32

10

15

17

4

7

10

40

2 N/O

1 NC

A2 2 4

6 14 22 32 44

32

10

15

17

4

7

10

40

3 N/O

2 NC

A1 1

3

5 13 21 31 43 53

A2 2 4

6 14 22 32 44 54

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
See also

24

Contact

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
012528
2411-03, 3211-04
UL Listed,
CSA certified
Page 80

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

A2 2 4

6 14 22 32 44 54

A1 1

3

5 13 21 33

A2 2 4

6 14 22 34

A1 1

5 13 21 31 43

3

Contactors
Complete device up to 170 A

1.1
1

AC operation
Part no.
Article no.

DC operation
Price
See
price list

Part no.
Article no.

DILM7-21(230V50Hz)
276620

DILM7-21(24VDC)
276635

DILM7-22(230V50Hz)
106360

DILM7-22(24VDC)
106367

DILM7-32(230V50Hz)
276655

DILM7-32(24VDC)
276670

DILM9-21(230V50Hz)
276760

DILM9-21(24VDC)
276775

DILM9-22(230V50Hz)
106361

DILM9-22(24VDC)
106368

DILM9-32(230V50Hz)
276795

DILM9-32(24VDC)
276810

DILM12-21(230V50Hz)
276900

DILM12-21(24VDC)
276915

DILM12-22(230V50Hz)
106362

DILM12-22(24VDC)
106369

DILM12-32(230V50Hz)
276935

DILM12-32(24VDC)
276950

DILM15-22(230V50Hz)
106363

DILM15-22(24VDC)
106370

DILM17-21(230V50Hz)
277068

DILM17-21(RDC24)
277082

DILM17-22(230V50Hz)
106364

DILM17-22(RDC24)
106371

DILM17-32(230V50Hz)
277100

DILM17-32(RDC24)
277114

DILM25-21(230V50Hz)
277196

DILM25-21(RDC24)
277210

DILM25-22(230V50Hz)
106365

DILM25-22(RDC24)
106372

DILM25-32(230V50Hz)
277228

DILM25-32(RDC24)
277242

DILM32-21(230V50Hz)
277324

DILM32-21(RDC24)
277338

DILM32-22(230V50Hz)
106366

DILM32-22(RDC24)
106373

DILM32-32(230V50Hz)
277356

DILM32-32(RDC24)
277370

Price
See
price list

Std. pack

Notes

1 off

2

Accessories
1 Overload relay
2 Suppressor
Accessories

1

Page
Chapter 1.2
50
52

For all DC operated contactors DILM7 - DILM15 the following applies:
• Integrated varistor suppressor circuit.
For DC operated contactors DILM17 - DILM170 the following applies:
• Integrated suppressor circuit in actuating electronics
For AC operated contactors DILM115 - DILM170 the following applies:
• Integrated suppressor circuit in actuating electronics
For DILM7 - DILM150 the following applies:
• With mirror contact.
Contacts to EN 50012

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

25

1.1

Contactors
Complete device up to 170 A

DILM complete device

1

Screw terminals

Screw terminals

Rated operational current
AC-3

Max. motor rating for
three-phase motors 50 - 60 Hz
AC-3
AC-4

380 V
400 V

220 V
230 V

380 V
400 V

660 V
690 V

220 V
230 V

380 V
400 V

660 V
690 V

Ie

P

P

P

P

P

P

Open
Ith = Ie

A

kW

kW

kW

kW

kW

kW

A

40

12.5

18.5

23

5

9

12

50

15.5

22

30

6

10

65

20

30

35

7

12

80

25

37

63

12

20

Conventional
free air
thermal
current Ith = Ie
AC-1 at 60 °C

Circuit symbol

Contact configuration:
= Safety function by
positive opening according
to IEC/EN 60947-5-1
N/O = normally
open contact

NC = normally
closed contact

50

2 N/O

2 NC

14

65

2 N/O

2 NC

17

80

2 N/O

2 NC

26

90

2 N/O

2 NC

95

30

45

75

16

26

35

110

2 N/O

2 NC

115

37

55

90

17

28

43

130

2 N/O

2 NC

150

48

75

96

20

34

48

160

2 N/O

2 NC

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
See also

26

Contact

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
012528
2411-03, 3211-04
UL Listed,
CSA certified
Page 80

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

Contactors
Complete device up to 170 A

1.1
1

AC operation
Part no.
Article no.

DC operation
Price
See
price list

Part no.
Article no.

DILM40-22(230V50Hz)
277798

DILM40-22(RDC24)
277812

DILM50-22(230V50Hz)
277862

DILM50-22(RDC24)
277876

DILM65-22(230V50Hz)
277926

DILM65-22(RDC24)
277940

DILM80-22(230V50Hz)
239449

DILM80-22(RDC24)
239463

DILM95-22(230V50Hz)
239527

DILM95-22(RDC24)
239541

DILM115-22(RAC240)
239578

DILM115-22(RDC24)
239581

DILM150-22(RAC240)
239598

DILM150-22(RDC24)
239601

Price
See
price list

Std. pack

Notes

1 off

2

Accessories
1 Overload relay
2 Suppressor
Accessories

1

Page
Chapter 1.2
50
52

For DC operated contactors DILM17 - DILM170 the following applies:
• Integrated suppressor circuit in actuating electronics
For AC operated contactors DILM115 - DILM170 the following applies:
• Integrated suppressor circuit in actuating electronics
For DILM7 - DILM150 the following applies:
• With mirror contact.
Contacts to EN 50012

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

27

1.1

Contactors DILM, DILH
Standard devices greater than 150 A

DILM...S/22...
Standard device for currents greater than 150 A

1

DILM complete device

Rated
operational
current

Max. motor rating for
three-phase motors 50 - 60 Hz

AC-3

AC-3

380 V
400 V
Ie

220 V
230 V
P

380 V
400 V
P

660 V
690 V
P

220 V
230 V
P

380 V
400 V
P

660 V
690 V
P

Ith = Ie

A

kW

kW

kW

kW

kW

kW

A

250

75

132

240

62

110

189

400

300

DILM complete device

400

500

580

Notes

90

125

155

185

Conventional
thermal current
Ith = Ie
AC-1 at 40 °C
Open

AC-4

160

200

250

315

195

344

344

344

75

92

112

112

132

160

160

283

200

344

200

344

430

612

857

920

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

1) Availability from August 2010.
Previous DILM300/22, see Online Catalog at http://www.eaton.com/seasia-electrical

For all contactors the following applies:
• 660 V, 690 V or 1000 V: do not reverse directly
• Integrated suppressor circuit in actuating electronics.
DILM…-S contactors are actuated conventionally

(+) L1
(–) N
A2
A1

Stopping in the event of an emergency (emergency switching off)
Accessories
Auxiliary contact modules
Enclosures
Further actuating voltages

28

Circuit symbol

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Page
38
77

For use with

DILM820-XHI…

DILM820-XHI…

DILM820-XHI…

DILM820-XHI…

DILM820-XHI…

Contactors DILM, DILH
Standard devices greater than 150 A

1.1
1

Part no.
Article no.

Price
See price
list

Std. pack

Information relevant for export to North America

DILM250-S/22(220-240V50/60Hz)
274190

1 off

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

DILM300A-S/22(220-240V50/60Hz) 1)
139559

1 off

Request filed for UL and CSA

DILM400-S/22(220-240V50/60Hz)
274196

1 off

DILM500-S/22(220-240V50/60Hz)
274199

1 off

DILM570-S/22(220-240V50/60Hz)
110744

1 off

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
See also

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
1017510
3211-04
UL Listed, CSA certified

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
012528
3211-04
UL Listed, CSA certified
Additional approvals,
Page 82

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

29

1.1

Contactors DILM, DILH
Comfort devices greater than 150 A

DILM, DILH

1

Rated
operational
current

Contactors, comfort DILM

Max. motor rating for
three-phase motors 50 - 60 Hz

AC-3

AC-3

380 V
400 V
Ie
A

220 V
230 V
P

185
225

AC-4
660 V
690 V
P

1000 V
P

220 V
230 V
P

kW

380 V
400 V
P
kW

kW

kW

55

90

140

108

70

Conventional
thermal
current I th = Ie
AC-1 at 60 °C
Open

110

150

108

660 V
690 V
P

1000 V

I th = Ie

P

A

kW

380 V
400 V
P
kW

kW

kW

41

75

102

77

51

110

90

77

275
315

250

75

132

195

108

62

110

160

109

330

300

90

160

195

132

75

132

160

109

350

400
500

580

125
155

185

200
250

315

344
344

560

132
132

600

92
112

143

160
200

250

283
344

440

132
132

509

500
700

800

650

205

355

630

600

161

280

494

509

850

750

240

400

720

800

181

315

556

678

900

820

260

450

750

800

209

355

633

678

1000

Circuit symbol

A1 1

3

6 14 22 32 44

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44

A1 1

5 13 21 31 43

3

A2 2 4

6 14 22 32 44
5 13 21 31 43

1000

315

560

1000

1100

260

450

780

1000

1000

A1 1

A2 2 4

6 14 22 32 44

1600

500

900

1600

1770

430

750

1300

1650

1800

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

Notes

3

1) Availability from August 2010.
Previous DILM185/22 to DILM300/22, see Online Catalog at http://www.eaton.com/seasia-electrical

For all contactors the following applies:
• 660 V, 690 V or 1000 V: do not reverse directly
• Integrated suppressor circuit in actuating electronics.
When operating contactors DILM580 to DILM1600 behind a frequency inverter or mains with
strong harmonic loads, the suppressor circuit on the load side must be removed.
During high-voltage tests, the suppressor circuit on the load-side for DILM580 to DILH2600 contactors
must be disconnected (see instructional leaflet).
Control voltages
RA250 110 V - 250 V AC/DC
RAW250 230 V - 250 V AC/DC
Accessories
Auxiliary contact modules
Suppressor circuits on load side
Enclosures
Further actuating voltages
30

5 13 21 31 43

A2 2 4

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Page
38
61
72

1.1

Contactors DILM, DILH
Comfort devices greater than 150 A

1
Part no.
Article no.

Price
See price
list

DILM185A/22(RAC240)1)
139537

Std. pack

Notes

1 off

Conventional
A1/A2 are attached
to power supply as
normal

DILM225A/22(RAC240)1)
139547

DILM 185 A, DILM 225 A

DILM250 to DILM1000, DILH1400 DILM1600 to DILH 2600
(+) L1
(–) N

(+) L1
(–) N

(+) L1
(–) N

A2

A10

A2

A10

A2

A1

A11

A1

A11

A1

A3

TY

A3

A4

TX

A4

DILM250/22(RA250)2)
208201
DILM300A/22(RA250)1) 2)
139556

Directly from the PLC
A 24 V output from
the PLC can be
directly connected
to the terminals A4/
A24.

(+) L1
(–) N

(+) L1
(–) N

DILM400/22(RA250)3)
208209

A10

A2

A11

A1

A3

A10

A2

A11

A1

TY

A3

TX

A4

A4

DILM500/22(RA250)3)
208213

24 V
GND

24 V
GND
From a low-power command device
Low-power
actuating devices
such as PCB relays,
pilot devices or
position switches
can be directly
connected to A10/
A11.

DILM580/22(RA250)3)
208216
DILM650/22(RA250)3)
208219
DILM750/22(RA250)3)
208222
DILM820/22(RA250)3)
208225

(+) L1
(–) N

(+) L1
(–) N
A10

A2

A10

A2

A11

A1

A11

A1

A3

TY

A3

A4

TX

A4

Stopping in the event of an emergency (emergency switching off)
Max. cable capacitance 6 nF

DILM1000/22(RA250)3)
267214
DILM1600/22(RAW250)3)
106727

Information relevant for export to North America

1)

NA Certification

Request filed for UL and CSA

2)

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
1017510
3211-04
UL Listed, CSA certified

3)

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
See also

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
012528
3211-04
UL Listed, CSA certified
Additional approvals,
Page 82
AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

31

1.1

Contactors DILM, DILH
Comfort devices greater than 150 A

DILM, DILH

1

Conventional thermal current Ith = Ie
AC-1 at 60 °C
Open

Circuit symbol

Part no.
Article no.

Price
See price
list

Std. pack

Ith = Ie
A
DILH comfort devices AC-1

1400
2000
2200
2600

Notes

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

A1 1

3

5 13 21 31 43

A2 2 4

6 14 22 32 44

DILH1400/22(RAW250)1)
272441

1 off

DILH2000/22(RAW250)1)
272442

1 off

DILH2200/22(RAW250)1)
111793

1 off

DILH2600/22(RAW250) 2)
125945

1 off

For all contactors the following applies:
• 660 V, 690 V or 1000 V: do not reverse directly
• Integrated suppressor circuit in actuating electronics.
When operating contactors DILM580 to DILM1600 behind a frequency inverter or mains with
strong harmonic loads, the suppressor circuit on the load side must be removed.
During high-voltage tests, the suppressor circuit on the load-side for DILM580 to DILH2600 contactors
must be disconnected (see instructional leaflet).
Control voltages
RAW250 230 V - 250 V AC/DC

Accessories
Auxiliary contact modules
Suppressor circuits on load side
Enclosures

32

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Page
38
61

Contactors DILM, DILH
Comfort devices greater than 150 A

1.1
1

Notes

Conventional
A1/A2 are attached to power
supply as normal

Directly from the PLC
A 24 V output from the PLC can
be directly connected to the
terminals A4/A24.

DILH1400

DILM1600 to DILH 2600

(+) L1
(–) N

(+) L1
(–) N
A10

A2

A10

A2

A11

A1

A11

A1

A3

TY

A3

A4

TX

A4

(+) L1
(–) N

(+) L1
(–) N
A10

A2

A11

A1

A3

A10

A2

A11

A1

TY

A3

TX

A4

A4

24 V
GND

24 V
GND
From a low-power command device
Low-power actuating devices
such as PCB relays, pilot
devices or position switches
can be directly connected to
A10/A11.

(+) L1
(–) N

(+) L1
(–) N
A10

A2

A10

A2

A11

A1

A11

A1

A3

TY

A3

A4

TX

A4

Stopping in case of emergency (Emergency-stop)
Max. cable capacitance 6 nF
Information relevant for export to North America

1)

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
012528
3211-04
UL Listed, CSA certified

2)

NA Certification

Request filed for UL and CSA

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

33

1.1

Leistungsschütze
Basic devices up to 200 A

DILMP 4 pole

1

Rated operational current open

Conventional thermal current
I th = Ie AC-1 at 50 °C
Open

AC-1
40 °C

55 °C

70 °C

A

A

A

A

22

21

30

20

Circuit symbol

For use with

I th = I e
Contactors up to 200 A
4 pole

Notes

1)

A1 1

3

5 7

A2 2

4

6 8

DILM1000-XHI…can only be fitted on the left of DILMP.

Contacts to EN 50012.
For DC operated contactors DILMP20 the following applies:
• Integrated varistor suppressor circuit.
For DC operated contactors DILMP32 - DILMP200 the following applies:
• Integrated suppressor circuit in actuating electronics.
For AC operated contactors DILMP125 - DILMP200 the following applies:
• Integrated suppressor circuit in actuating electronics.
For DILMP32-01 and DILMP45-01 the following applies:
• With mirror contact.

34

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

DILM32-XHI(C)…
DILA-XHI(V)(C)…

Leistungsschütze
Basic devices up to 200 A

AC operation

1.1
1

DC operation
Price
See
price
list

Part no.
Article no.

DILMP20(230V50Hz,240V60Hz)
276970

Std. pack

Part no.
Article no.

1 off

DILMP20(24VDC)
276985

Price
See
price list

Std. pack

Notes

1 off

1

1
2
Accessories
1 Auxiliary contact module
2 Suppressor
Further actuating voltages
Accessories

Page
36
50
74
52

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
See also

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
012528
2411-03, 3211-04
UL Listed, CSA certified
Page 81

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

35

1.1

Contactors
Auxiliary contact modules

DILM, DILA
Auxiliary contact modules

1

With interlocked opposing contacts, except ...XHI(C)V
Terminal
type

Top mounting auxiliary contacts

Screw
terminals

Pole

Conventional
thermal current
Ith = Ie
AC-1 at 60 °C
Open
Ith = Ie
A

Contact
configuration

Circuit
symbol

Screw
terminals

2 pole

16

1 N/O

1 NC

2 pole

16

–

1 NC

21 33

22 34
21 31

4 pole

16

2 N/O

2 NC

21 31 43 53

4 pole

16

3 N/O

1 NC

21 33 43 53

22 32 44 54

22 34 44 54

Top mounting auxiliary contacts

Springloaded
terminals

2 pole

16

Part no.
Article no.

DILM(C)7-10…
DILM(C)9-10…
DILM(C)12-10…
DILM(C)15-10…
DILM(C)17-10…
DILM(C)25-10…
DILM(C)32-10…
DILM38-…10
DILMP20…
DILMP32-10…
DILMP45-10…
DILL…

DILM32-XHI11
277376

5 off

DILM32-XHI02
277375

5 off

DILM32-XHI22
277377

5 off

DILM32-XHI31
106112

5 off

1 N/O

1 NC

21 33

DILM32-XHIC11
277751

5 off

DILM32-XHIC02
277750

5 off

DILM32-XHIC22
277752

5 off

DILA-XHI20
276422

5 off

DILA-XHI11
276421

5 off

DILA-XHI02
276420

5 off

DILA-XHIV11
276423

5 off

DILA-XHI40
276428

5 off

DILA-XHI31
276427

5 off

DILA-XHI22
276426

5 off

DILA-XHI13
276425

5 off

DILA-XHI04
276424

5 off

DILA-XHIV22
276429

5 off

22 34

2 pole

16

–

2 NC

21 31

22 32

Top mounting auxiliary contacts

Top mounting auxiliary contacts

Springloaded
terminals

4 pole

Screw
terminals

2 pole

16

2 N/O

2 NC

21 31 43 53

22 32 44 54

16

1 N/O

–

53 63

54 64

2 pole

16

1 N/O

1 NC

53 61

54 62
51 61

2 pole

16

–

2 NC

2 pole

16

1 SF

1 ÖS

57 65

4 pole

16

4 N/O

–

53 63 73 83

52 62

58 66

Top mounting auxiliary contacts

Screw
terminals

DILM(C)9…
DILM(C)9…
DILM(C)12…
DILM(C)15…
DILM(C)17…
DILM(C)25…
DILM(C)32…
DILM38…
DILMP20…
DILMP32…
DILMP45…
DILL…

54 64 74 84

4 pole

16

3 N/O

1 NC

53 61 73 83

54 62 74 84

4 pole

16

2 N/O

2 NC

53 61 71 83

54 62 72 84

4 pole

16

1 N/O

3 NC

53 61 71 81

54 62 72 82

4 pole

16

–

4 NC

51 61 71 81

52 62 72 82

4 pole

16

1 N/O
1 SF

1 NC
1 ÖS

57 65 71 83

58 66 72

Notes
• Auxiliary NC usable as mirror contact according to IEC/EN 60947-4-1,
Annex F
• Interlocked opposing contacts according to IEC/EN 60947-5-1 Annex L,
inside the auxiliary contact modules, also for the
integrated auxiliary contacts of the DILM 7 - DILM32

36

Price
See price
list

Std. pack

N/O = normally open
contact
S F = N/O early-make
NC = normally closed
contact
Ö S = NC late-break

22 32

Top mounting auxiliary contacts

For use with

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

84

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05; CE marking
E29184
NKCR
012528
3211-03
UL Listed, CSA certified

1.1

Contactors
Auxiliary contact modules

DILM, DILA
Auxiliary contact modules

1

With interlocked opposing contacts, except ...XHI(C)V
Terminal
type

Top mounting auxiliary contacts

Springloaded
terminals

Conventional
thermal current
I th = I e
AC-1 at 60 °C
Open
I th = I e
A

Contact
configuration

2 pole

16

2 N/O

–

2 pole

16

1 N/O

1 NC

Pole

Circuit
symbol

53 63

54 64
53 61

2 pole

16

–

2 NC

2 pole

16

1 SF

1 ÖS

51 61

52 62
57 65

58 66

Screw
terminals

2 pole
2 pole

16
16

Part no.
Article no.

DILM(C)7…
DILM(C)9…
DILM(C)12…
DILM(C)15…
DILM(C)17…
DILM(C)25…
DILM(C)32…
DILM38…
DILMP20…
DILMP32…
DILMP45…
DILL…

DILA-XHIC20
276528

5 off

DILA-XHIC11
276527

5 off

DILA-XHIC02
276526

5 off

DILA-XHICV11
276529

5 off

2 N/O
1 N/O

2 NC
1 NC

53

63 71 81

DILA-XHIR221)
139580

54

64 72 82

5 off

DILA-XHIR11
110140

5 off

DILA-XHIC40
276534

5 off

DILA-XHIC31
276533

5 off

DILA-XHIC22
276532

5 off

DILA-XHIC13
276531

5 off

DILA-XHIC04
276530

5 off

DILA-XHICV22
276535

5 off

53 61

54 62

Top mounting auxiliary contacts

Springloaded
terminals

4 pole

16

4 N/O

–

53 63 73 83

54 64 74 84

4 pole

16

3 N/O

1 NC

53 61 73 83

54 62 74 84

4 pole

16

2 N/O

2 NC

DILM(C)9…
DILM(C)9…
DILM(C)12…
DILM(C)15…
DILM(C)17…
DILM(C)25…
DILM(C)32…

53 61 71 83

54 62 72 84

4 pole

16

1 N/O

3 NC

53 61 71 81

54 62 72 82

4 pole

16

–

4 NC

4 pole

16

1 N/O
1 SF

1 NC
1 ÖS

51 61 71 81

52 62 72 82
57 65 71 83

58 66 72

Notes
• Auxiliary NC usable as mirror contact according to IEC/EN 60947-4-1,
Annex F
• Interlocked opposing contacts according to IEC/EN 60947-5-1 Annex L,
inside the auxiliary contact modules, also for the
integrated auxiliary contacts of the DILM 7 - DILM32
1)

Price
See price
list

Std. pack

N/O = normally open
contact
S F = N/O early-make
NC = normally closed
contact
Ö S = NC late-break

54 62

Top mounting auxiliary contacts

For use with

1 N/C + 1 N/O above microswitch for electronic applications

84

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05; CE marking
E29184
NKCR
012528
3211-03
UL Listed, CSA certified

1)

NA Certification

Request filed for UL and CSA

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

37

1.1

Contactors
Auxiliary contact modules

DILM
Auxiliary contact modules

1

With interlocked opposing contacts

Top mounting
auxiliary
contacts

Connection
type

Pole

conventional
thermal
current
Ith = Ie
AC-1 at 60 °C
Open
Ith = Ie
A

Contact
configuration
N/O = normally
open contact
SF = N/O early
make
NC = normally
closed contact
ÖS = NC latebreak

Screw
terminals

2 pole

16

2 N/O

–

Circuit
symbol

13 23

14 24

2 pole

16

1 N/O

1 NC

13 21

14 22

2 pole

16

1 N/O

1 NC

53 61

54 62

2 pole

16

–

2 NC

11 21

12 22

Top mounting
auxiliary
contacts

Screw
terminals

4 pole

16

4 N/O

–

13 23 33 43

14 24 34 44

4 pole

16

3 N/O

1 NC

For use with

Part no.
Article no.

DILM40…
DILM50…
DILM65…
DILM72…
DILM80…
DILM95…
DILM115…
DILM150…
DILM170…
DILMP63…
DILMP80…
DILMP125…
DILMP160…
DILMP200…

13 21 33 43

14 22 34 44

4 pole

16

2 N/O

2 NC

13 21 31 43

14 22 32 44

4 pole

16

2 N/O

2 NC

53 61 71 83

54 62 72 84

4 pole

16

1 N/O

3 NC

13 21 31 41

Price
See
price
list

Std. pack

Notes

DILM150-XHI20
277945

5 off

DILM150-XHI11
277946

5 off

DILM150-XHIA11
283463

5 off

DILM150-XHI02
277947

5 off

DILM150-XHI40
277948

5 off

Interlocked
opposing contacts
according to
IEC/EN 60947-5-1
Annex L, inside the
auxiliary contact
modules
Auxiliary NC
usable as mirror
contact according
to IEC/EN 60947-4-1,
Annex F

DILM150-XHI31
277949

5 off

DILM150-XHI22
277950

5 off

DILM150-XHIA22
283464

5 off

DILM150-XHI13
277951

5 off

DILM150-XHI04
277952

5 off

DILM150-XHIV22
277953

5 off

–

DILA-XHIT20
101042

5 off

DILA-XHIT11
101043

5 off

DILA-XHIT02
101041

5 off

DILA-XHIT22
101044

5 off

Interlocked
opposing contacts
according to
IEC/EN 60947-5-1
Annex L, inside the
auxiliary contact
modules
Auxiliary NC
usable as mirror
contact according
to IEC/EN 60947-4-1,
Annex F

14 22 32 42

4 pole

16

–

4 NC

11 21 31 41

12 22 32 42

4 pole
High version1)

2 pole

Screw
terminals

16
16

1 N/O
1 SF

1 NC
1 ÖS

2 N/O

–

13 21 35 47

14 22 36 48
53 63

54 64

2 pole

16

1 N/O

1 NC

53 61

54 62

2 pole

16

–

2 NC

DILM7…
DILM9…
DILM12…
DILM15…
DILL…

51 61

52 62

High version1)

Screw
terminals

4 pole

16

2 N/O

2 NC

53 61 71 83

54 62 72 84

Notes

1)

Suitable for the combination with electrical wiringlinks
in tool-less plug connection usable with:
DILM12-XSL
DILM12-XRL
DILM12-XS1
PKZM0-XDM12
PKZM0-XRM12
PKZM0-XSM12

Information relevant for export to North America
Product Standards
1

4

1 PKZM0
2 DILM7 - DILM15
3 DILA-XHIT
4 PKZM0-XDM12

38

2
3

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05; CE marking
E29184
NKCR
012528
3211-03
UL Listed, CSA certified

1.1

Contactors
Auxiliary contact modules

DILM, DILA

Side-mounting
auxiliary contacts

1

Connection
type

Pole

conventional
thermal
current
Ith = Ie
AC-1 at 60 °C
Open
Ith = Ie
A

Contact
configuration
N/O = normally
open contact
SF = N/O early
make
NC = normally
closed contact
ÖS = NC latebreak

Screw
terminals

1 pole

10

1 N/O

–

1 pole

10

–

1 NC

Circuit
symbol

53

54
61

62

Springloaded
terminals

1 pole

10

1 N/O

–

53

For use with

Part no.
Article no.

DILM(C)7…
DILM(C)9…
DILM(C)12…
DILM(C)15…
DILMP20…
DILA(C)…

Std. pack

Notes

DILA-XHI10-S
115948

1 off

1)

DILA-XHI01-S
115949

1 off

DILA-XHIC10-S
115950

1 off

DILA-XHIC01-S
115951

1 off

DILM17…
DILM25…
DILM32…
DILM38…

DILM32-XHI11-S
101371

1 off

Can only be left on
the contactor.
Cannot be
combined with
mechanical
interlock

DILM250 DILH2600

DILM820-XHI11-SI
208281

1 off

1)

DILM820-XHI11-SA
208282

1 off

DILM820-XHI11V-SI
208283

1 off

DILM1000-XHI11-SI
278425

1 off

DILM1000-XHIV11-SI
278426

1 off

DILM1000-XHI11-SA
278427

1 off

54

1 pole

10

–

1 NC

61

62

Side-mounting
auxiliary contacts

Screw
terminals

2 pole

Side-mounting
auxiliary contacts

Screw
terminals

2 pole

10

1 N/O

1 NC

2 pole

10

1 N/O

1 NC

47

21

43

22

31

48

25

36

47

26

35

84

61

72

83

62

71

54

44

53

26

35

18

25

32

17

48

14

83

13

62

36

1 NC

18

61

71

1 N/O

1 ÖS

17

43

10

1 SF

1 NC

54

22

84

10

1 N/O

1 ÖS

53

31

10

1 SF

14

21

72

2 pole

10

13

44

2 pole
2 pole

Notes

53 61

1 NC

32

Screw
terminals

1 N/O

54 62

2 pole
Side-mounting
auxiliary contacts

10

DILM40 DILM225A
DILMP63 DILMP200

Price
See
price
list

Information relevant for export to North America

1)

• Interlocked opposing contacts according to IEC/EN 60947-5-1
Annex L, inside the auxiliary contact module, also for the integrated auxiliary contacts of the DILM7 – DILM32 (not NO earlymake and NC late-break)
• Auxiliary NC usable as mirror contact according to IEC/EN 609474-1, Annex F (no NC late-breaks)
• No auxiliary contact is possible between 2 contactors with
mechanical interlock.

2)

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05; CE marking
E29184
NKCR
012528
3211-03,3211-04
UL Listed, CSA certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

39

1.1
1

Contactors
Auxiliary contact modules

Engineering
DILM, DILH

DILM1000XHI(V)11-SI

DILM820XHI(V)11-SI

DILM1000XHI(V)11-SA

DILM820XHI(V)11-SA

DILM150-XHI20
DILM150-XHI11
DILM150-XHI02

DILM150-XHI40
DILM150-XHI31
DILM150XHI(V)22
DILM150-XHI13
DILM150-XHI04

DILM150XHIA11

DILM150XHIA22

2x
–

–
–

–
2x

–
–

–
1x

–
–

1x
–

–
–

1x
–
2x
2x

–
–
–
–

–
1x
2x
–

–
–
–
–

–
–
–
–

–
1x
–
–

–
–
–
–

1x
–
–
1x

2x

–

–

–

–

–

1x

–

–
–
2x
2x
–

–
–
–
–
2x

2x
2x
2x
–
–

–
–
–
–
2x

–
1x
–
–
–

1x
–
–
–
–

–
–
–
–
–

–
–
–
–
–

DILH1400
...
DILH2600

–

2x

–

2x

–

–

–

–

Notes

Side mounting auxiliary contacts

DILM40
...
DILM72

DILM80
...
DILM170

DILM185A
DILM222A
DILM250
DILM1600

DILM1000-XHI(C)..-SI

DILM1000-XHI(C)..

+
+

+

+

+

+

DILM1000-XHI(C)..-SA
DILM820-XHI(C)..-SI

+

+

+

+

DILM820-XHI(C)..-SA

DILM40 – DILM72
DILM250 – DILH2600
DILM80-DILM225A
•
•
•
•
•

40

Interlocked opposing contacts according to IEC/EN 60947-5-1 Annex L, inside the auxiliary contact module (not N/O early close and N/C late open)
Auxiliary contacts can be used as mirror contacts according to IEC/EN 60947-4-1, Annex F (not N/C late open)
No auxiliary contact is possible between two contactors with mechanical interlock.
2 auxiliary contacts DILM820-XHI11-SI are already built into the contactors DILM250 to DILH2600/22.
2 DILM1000-XHI11-SI auxiliary contacts are already installed in DILM185A and DILH225A contactors.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Contactors
Contactor for capacitors

1.1

Ordering

1

DILK
Three-phase capacitors
50 – 60 Hz
Open
230 V

With series resistors
Basic Units

Notes

400 V

Circuit symbol

525 V

690 V

kvar

kvar

kvar

kvar

7.5

12.5

16.7

20

11

20

25

33.3

15

25

33.3

40

20

33.3

40

55

25

50

65

85

Part no.
Article no.

A1

1 3 5 13 21

A2

2 4 6 14 22

3 5 13

A1

1

A2

2 4 6 14

Price
See price
list

Std. pack

DILK12-11(230V50Hz,240V60Hz)
293988
DILK20-11(230V50Hz,240V60Hz)
294010

1 off

DILK25-11(230V50Hz,240V60Hz)
294032
DILK33-10(230V50Hz,240V60Hz)
294054
DILK50-10(230V50Hz,240V60Hz)
294076

1 off

1 off

1 off
1 off

Weld-resistant for capacitors with inrush current peaks up to 180 x IN
With group compensation multi-stage capacitor banks are connected to the mains as required. This can cause, transient currents of up to 180 x Ie
to flow between the capacitors.
The capacitors are pre-charged via the early-make auxiliary contacts and the fitted wire resistors, thereby reducing the inrush current. The main
contacts then close after a time lag and carry the continuous current.
The contactors for capacitors are weld-resistant with inrush current peaks up to 180 x le due to their special contacts.
DILK… cannot be combined with other auxiliary contacts.
For the switching of reactive-power compensation equipment please see Engineering notes on power factor correction
page 33.
L1 L2 L3

A1

1 3 5

A2

2 4 6

R11

R11
C1

R11

Accessories
Enclosures
Accessories
Further actuating
voltages

Page
52
76

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
See also

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
012528
3211-04
UL Listed, CSA certified
Further approvals
Page 66

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

41

1.1
1

Contactors
Contactors for power factor correction

Engineering
DILM, DILK
Ordering data

Part no.
DILM7-…(…)
DILM9-…(…)
DILM12-…(…)
DILM15-…(…)
DILM17-…(…)
DILM25-…(…)
DILM32-…(…)
DILM40(…)
DILM50(…)
DILM65(…)
DILM80(…)
DILM95(…)
DILM115(…)
DILM150(…)
DILM185A(…)
DILM300A(…)
DILM580(…)
DILM7-…(…)
DILM9-…(…)
DILM12-…(…)
DILM15-…(…)
DILM17-…(…)
DILM25-…(…)
DILM32-…(…)
DILM40(…)
DILM50(…)
DILM65(…)
DILM80(…)
DILM95(…)
DILM115(…)
DILM150(…)
DILM185A(…)
DILM225A(…)
DILM250(…)
DILM300A(…)
DILM400(…)
DILM500(…)
DILK12-…(…)
DILK20-…(…)
DILK25-…(…)
DILK33-…(…)
DILK50-…(…)
DILM185A(…)
DILM300A(…)
DILM580(…)
Notes

42

Page
18
18
18
18
18
18
18
20
20
20
20
20
20
20
30
30
30
18
18
18
18
18
18
18
20
20
20
20
20
20
20
30
30
30
30
30
30
41
41
41
41
41
30
30
30

Switching power
230 V

400 V
420 V
440 V
kvar

525 V

690 V

kvar

kvar

Individual compensation, open version
1.5
3

3.5

5

2
2.5
2.5

4
4.5
4.5

4.5
5.5
5.5

6
7
7

6.5
7
7.5
11
11.5
12.5
16
18
24

12
13.5
14.5
20.5
22
23.5
30.5
34
46

14.5
16
17
24.5
26
28
36.5
41
54.5

19
21
22.5
32
34.5
37
48
54
72

28
87
115

53
150
200

63.5
190
265

83.5
150
200

175
300
400
Group compensation, with choke, open version

300

4
5

7
8

7.5
10

12
14

5.5
5.5
7.5

10
10
18

12
12
20

16
16
28

10
12.5
15
20
25
30
35
50

20
25
30
40
50
60
70
95

23
25
30
40
50
70
80
100

30
32
40
48
57
90
104
125

55

115

115

152

80
100
110
130

150
175
190
225

200
230
260
290

260
300
340
390

160
280
370
220
390
500
Group compensation, without choke, open version

480
680

kvar

7.5

12.5

16.7

20

11
15
20
25
66
85
145

20
25
33.3
50
115
150
250

25
33.3
40
65
145
195
333

33.3
40
55
85
115
150
250

Use of the contactors DILM without series resistor for group compensation
When using the contactors for group compensation in a system without chokes each capacitor must have a minimum
induction of approx. 6 μH to limit the peak inrush current. This corresponds to an air-cored coil with 5 windings and a coil
diameter of approximately Ø 140 mm. The conductor cross section must correspond to the rated operational current.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1
Ordering
1

44

Contactor combinations
Star-delta combinations
Star-delta combinations SDAINL
Operating frequency: maximum 30 starts per hour
Rated operational current
AC-3
400 V
Ie
A

Max. rated operational power for
three-phase motors, 50 - 60 Hz
AC-3
230 V
400 V
500 V
690 V
P
P
P
P
kW
kW
kW
kW

Max.
changeover time
s

Part no.
Article no.

12

4

5.5

5.5

–

< 30

SDAINLEM(230V50Hz)
051840

1 off

12

3

5.5

5.5

5.5

< 20

SDAINLM12(230V50Hz)
278286

1 off

12

3

5.5

5.5

5.5

< 20

SDAINLM12(400V50Hz)
101380

1 off

12

3

5.5

5.5

5.5

< 20

SDAINLM12(24VDC)
100416

1 off

16

4

7.5

7.5

7.5

< 20

SDAINLM16(230V50Hz)
278311

1 off

16

4

7.5

7.5

7.5

< 20

SDAINLM16(400V50Hz)
101381

1 off

16

4

7.5

7.5

7.5

< 20

SDAINLM16(24VDC)
100417

1 off

22

5.5

11

11

11

< 20

SDAINLM22(230V50Hz)
278336

1 off

22

5.5

11

11

11

< 20

SDAINLM22(400V50Hz)
101382

1 off

22

5.5

11

11

11

< 20

SDAINLM22(24VDC)
100418

1 off

30

7.5

15

18.5

18.5

< 20

SDAINLM30(230V50Hz)
278361

1 off

30

7.5

15

18.5

18.5

< 20

SDAINLM30(400V50Hz)
101383

1 off

30

7.5

15

18.5

18.5

< 20

SDAINLM30(RDC24)
100419

1 off

45

11

22

30

22

< 20

SDAINLM45(230V50Hz)
278386

1 off

45

11

22

30

22

< 20

SDAINLM45(400V50Hz)
101384

1 off

45

11

22

30

22

< 20

SDAINLM45(RDC24)
100420

1 off

55

15

30

37

30

< 20

SDAINLM55(230V50Hz)
278411

1 off

55

15

30

37

30

< 20

SDAINLM55(400V50Hz)
101385

1 off

55

15

30

37

30

< 20

SDAINLM55(RDC24)
100421

1 off

70

18.5

37

45

37

< 20

SDAINLM70(230V50Hz)
239895

1 off

70

18.5

37

45

37

< 20

SDAINLM70(400V50Hz)
101386

1 off

90

22

45

55

45

< 20

SDAINLM90(230V50Hz)
239937

1 off

115

30

55

75

55

< 20

SDAINLM115(230V50Hz)
239963

1 off

140

37

75

90

90

< 20

SDAINLM140(230V50Hz)
240009

1 off

165

45

90

110

132

< 20

SDAINLM165(230V50Hz)
240035

1 off

200

55

110

132

160

< 20

SDAINLM200(230V50Hz)
101010

1 off

260

75

132

160

160

< 20

SDAINLM260(230V50Hz)
101031

1 off

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Price
See price
list

Std.
pack

1.1

Contactor combinations
Star-delta combinations

I n d iv id u a l c o m p o n e n ts o f th e c o m b in a tio n

S p a r e a u x ilia r y c o n ta c ts
Q11

Notes

Mains contactor
Q11

Delta contactor
Q15

Star contactor
Q13

Timing relays
K1

Part no.

Part no.

Part no.

Part no.

DILEM-10
+ 22DILEM

DILEM-01

DILEM-10 +
02DILEM

DILET

DILM7-10
+ DILA-XHI20

DILM7-01
+ DILA-XHI20

DILM7-01
+ DILA-XHI20

ETR4-51

63

64

64

64

DILM7-10
+ DILA-XHI20

DILM7-01
+ DILA-XHI20

DILM7-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM7-10
+ DILA-XHI20

DILM7-01
+ DILA-XHI20

DILM7-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM9-10
+ DILA-XHI20

DILM9-01
+ DILA-XHI20

DILM7-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM9-10
+ DILA-XHI20

DILM9-01
+ DILA-XHI20

DILM7-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM9-10
+ DILA-XHI20

DILM9-01
+ DILA-XHI20

DILM7-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM12-10
+ DILA-XHI20

DILM12-01
+ DILA-XHI20

DILM7-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM12-10
+ DILA-XHI20

DILM12-01
+ DILA-XHI20

DILM7-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM12-10
+ DILA-XHI20

DILM12-01
+ DILA-XHI20

DILM7-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM17-10
+ DILA-XHI20

DILM17-01
+ DILA-XHI20

DILM17-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM17-10
+ DILA-XHI20

DILM17-01
+ DILA-XHI20

DILM17-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM17-10
+ DILA-XHI20

DILM17-01
+ DILA-XHI20

DILM17-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM25-10
+ DILA-XHI20

DILM25-01
+ DILA-XHI20

DILM17-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM25-10
+ DILA-XHI20

DILM25-01
+ DILA-XHI20

DILM17-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM25-10
+ DILA-XHI20

DILM25-01
+ DILA-XHI20

DILM17-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM32-10
+ DILA-XHI20

DILM32-01
+ DILA-XHI20

DILM25-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM32-10
+ DILA-XHI20

DILM32-01
+ DILA-XHI20

DILM25-01
+ DILA-XHI20

ETR4-51

63

63

63

64

64

64

DILM32-10
+ DILA-XHI20

DILM32-01
+ DILA-XHI20

DILM25-01
+ DILA-XHI20

ETR4-51

63

63

63

DILM40
+ DILM150-XHI31

DILM40
+ DILM150-XHI11

DILM40
+ DILM150-XHI11

ETR4-51

DILM40
+ DILM150-XHI31

DILM40
+ DILM150-XHI11

DILM40
+ DILM150-XHI11

ETR4-51

DILM50
+ DILM150-XHI31

DILM50
+ DILM150-XHI11

DILM40
+ DILM150-XHI11

ETR4-51

DILM65
+ DILM150-XHI31

DILM65
+ DILM150-XHI11

DILM40
+ DILM150-XHI11

ETR4-51

DILM80
+ DILM150-XHI31

DILM80
+ DILM150-XHI11

DILM50
+ DILM150-XHI11

ETR4-51

DILM95
+ DILM150-XHI31

DILM95
+ DILM150-XHI11

DILM65
+ DILM150-XHI11

ETR4-51

DILM115
+ DILM150-XHI31

DILM115
+ DILM150-XHI11

DILM80
+ DILM150-XHI11

ETR4-51

DILM150
+ DILM150-XHI31

DILM150
+ DILM150-XHI11

DILM95
+ DILM150-XHI11

ETR4-51

21 31 53

Q13

Q15

–

–

22 32 54

63

64

21 33

63

64

1

Main circuit:
Depending on the type of coordination required (i.e. Type
“1” or Type “2”) it must be established whether the fuse
protection and the input wiring for the mains contactor and
delta contactor are to be common or separate.
The following applies for SDAINLM 140 – SDAINLM 260:
• On the mounting plate.
Circuit diagrams, Star-delta combinations

page 46

1

Accessories
1 Overload relay
Accessories

Page
Chapter 1.2
52

64

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

22 34
21 33

22 34
21 33

22 34
21 33

22 34
21 33

22 34
21 33

22 34
21 33

22 34
21 33

22 34

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

45

1.1
1

Contactor combinations
Star-delta combinations

Engineering
SDAINL
Circuit diagrams, Star-delta combinations
SDAINLEM
21

L1L2 L3

0

22

F1

13

B

1 x In

14

Q11

I

14

13
44

14

Q11

1 3

5

2 4 6

1 3

Q15

A
0.58 x I n

5

Q13

2 4 6

1 3

43

5

13

16

2 4 6

Q15

A1

M1
M
3~

K1

V2
W2
U2

18

22

C
0.58 x I n
U1
V1
W1

15

K1

Q11 Q13

A2

A1

Q11

A1

Q13

A2

N

22

Q13

21

A2

21

A1

Q15

A2

Y

N

SDAINLM12…SDAINLM55
L1L2 L3

21

0
S11

F1

22

Q11
B

Q11

1 3

1 x In

5

1 3

Q15

2 4 6

I

5

Q13

2 4 6

13

13

14

14

Q11
1 3

5

54

54

54

53

53

53

Q13

2 4 6

K1

Q15

C
0.58 x I n
U1
V1
W1

M1
M
3~

(–)N

V2
W2
U2

21

A1

A1

Q11

K1

A2

K1

22

Q15
A
0.58 x I n

17
18

A2

N

A2

28
22

Q13

21
A1

A1

Q13

17

Q15

A2

Y

SDAINLM70…SDAINLM260
L1L2 L3

21

0
S11

F1

22

Q11
B

Q11

1 3

5

2 4 6

1 x In

1 3

Q15

I

5

2 4 6

Q13

13

13

14

14

Q11
1 3

5

44

14

14

43

13

13

Q13

2 4 6

K1

Q15

C
0.58 x I n
U1
V1
W1

M1
M
3~

A1

Q11
V2
W2
U2

(–)N

A2

N

K1

22

Q15
A
0.58 x I n

17
18

A2

Q13

A2

28
22

Q13

A1

A1

K1

21

17

21
A1

Q15

A2

Y

Overload relay settings
Starting
A: I N x 0.58
15 s
Motor protected in Y and - positions
B: I N x 1
15 – 40 s
Only partial motor protection in Y position
C: I N x 0.58
> 40 s
Motor not protected in Y position
Timing relay set to approx. 10 s
Main circuit:
Depending on the type of coordination required (i.e. Type “1” or Type “2”) it must be established whether the fuse protection and the input wiring for the mains
contactor and delta contactor are to be common or separate.
46

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactor combinations
Star-delta combinations

SDAINL
Components for self-assembly of star-delta combinations

1

Individual components of the combination

Maximum operational rating of AC
motors 50 - 60 Hz
AC-3

Changeover time1)

230 V

400 V

500 V

690 V

1000 V

kW

kW

kW

kW

kW

90

160

200

250

132

110

200

250

315

160

132

250

315

400

160

300

355

200

355

250

up to
12 s

up to
20 s

up to
30 s

Coil to EN 50005
Switching element to EN 50005 and EN 50012
Star
Delta
Mains
contactor
contactor
contactor
Q13
Q15
Q11
Part no. DIL
Part no. DIL
Part no. DIL

Timing
relay
K1
Part no.

M185A/22

ETR4-51

M185A/22

M115/22

M225A/22

M225A/22

M150/22

ETR4-51

200

M250/22

M250/22

M185A/22

ETR4-51

450

200

M300A/22

M300A/22

M185A/22

ETR4-51

450

560

220

M400/22

M400/22

M250/22

ETR4-51

450

560

600

220

M500/22

M500/22

M300A/22

ETR4-51

300

560

710

900

355

M580/22

M580/22

M400/22

ETR4-51

350

630

750

950

355

M650/22

M650/22

M400/22

ETR4-51

400

710

900

1200

1400

M750/22

M750/22

M580/22

ETR4-51

450

800

950

1300

1400

M820/22

M820/22

M580/22

ETR4-51

560

1000

1200

1700

1700

M1000/22

M1000/22

M650/22

ETR4-51

1)

Notes

–

Spare auxiliary contacts

–

–

1 3 5

1 3 5
Q11

Q15
2 4 6

21 31

31 43

22 32

32 44

32 44

21 31

31 43

31 43

31 43

22 32

32 44

32 44

21 31

31 43

31 43

22 32

32 44

32 44

21 31

31 43

31 43

22 32

32 44

32 44

21 31

31 43

31 43

22 32

32 44

32 44

21 31

31 43

31 43

22 32

32 44

32 44

21 31

31 43

31 43

22 32

32 44

32 44

21 31

31 43

31 43

22 32

32 44

32 44

21 31

31 43

31 43

22 32

32 44

32 44

21 31

31 43

31 43

22 32

32 44

32 44

21 31

31 43

31 43

22 32

32 44

32 44

C

1 3 5

1 3 5
Q11

2 4 6

Q15
2 4 6

1 3 5
Q13

2 4 6

A

2 4 6

C

1 3 5
Q13

Q15
2 4 6

2 4 6

A

U1
V1
W1

1 3 5
Q13

2 4 6

A
1 3 5

Q13

N o te s

B

1 3 5

Q15

Longer changeover times please enquire

Components for self-assembly

Q11

Q11

2 4 6

C

M1
3

V2
W2
U2

M1

Overload relay settings

Timing relay set to approx. 10 s
Starting

IN
A x 0.58
Motor protection in Y and

15 s
positions

Bx1
In Y position only limited motor protection

15 – 40 s

C x 0.58
Motor not protected in Y position

> 40 s

Main circuit:
Depending on the coordination type required (i.e.
Type “1” or Type “2”) it must be established whether
the fuse protection and the input wiring for the
mains contactor and delta contactor are to be
common or separate.
Control circuit:
If the combinations are to be used within the scope
of IEC/EN 60 204 Part 1, VDE 0113 Part 1, then Point
9.1.1 regarding the supply of control circuits, must
be observed.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

47

1.1
1

Contactor combinations
Reversing combinations

Ordering
DIUL reversing combinations

AC operation

AC operation

AC operation

Rated
operational
current

Max. motor rating for
three-phase motors 50 - 60 Hz

AC-3
400 V
Ie
A

AC-3
220 V
230 V
P
kW

380 V
400 V
P
kW

660 V
690 V
P
kW

AC-4
220 V
230 V
P
kW

380 V
400 V
P
kW

660 V
690 V
P
kW

9

2.2

4

4

1.5

3

3

DIULEM/21/MV(230V50Hz)1)
051849

1 Off

9

2.2

4

4

1.5

3

3

DIULEM/21/MV-G(24VDC) 2)
214655

1 Off

7

2.2

3

3.5

1

2.2

2.9

DIULM7/21(230V50Hz) 2)
278061

1 Off

7

2.2

3

3.5

1

2.2

2.9

DIULM7/21(24VDC)2)
107021

1 Off

9

2.5

4

4.5

1.5

2.5

3.6

DIULM9/21(230V50Hz) 2)
278086

1 Off

9

2.5

4

4.5

1.5

2.5

3.6

DIULM9/21(24VDC)2)
107022

1 Off

12

3.5

5.5

6.5

2

3

4.4

DIULM12/21(230V50Hz) 2)
278111

1 Off

12

3.5

5.5

6.5

2

3

4.4

DIULM12/21(24VDC)2)
107023

1 Off

18

5

7.5

11

2.5

4.5

6.5

DIULM17/21(230V50Hz) 2)
278136

1 Off

18

5

7.5

11

2.5

4.5

6.5

DIULM17/21(RDC24)2)
107024

1 Off

25

7.5

11

14

3.5

6

8.5

DIULM25/21(230V50Hz) 2)
278161

1 Off

25

7.5

11

14

3.5

6

8.5

DIULM25/21(RDC24)2)
107025

1 Off

32

10

15

17

4

7

10

DIULM32/21(230V50Hz) 2)
278186

1 Off

32

10

15

17

4

7

10

DIULM32/21(RDC24)2)
107026

1 Off

40

12.5

18.5

23

5

9

12

DIULM40/11(230V50Hz) 2)
278211

1 Off

50

15.5

22

30

6

10

14

DIULM50/11(230V50Hz) 2)
278236

1 Off

65

20

30

35

7

12

17

DIULM65/11(230V50Hz) 2)
278261

1 Off

Price
See
price list

Std. pack

Information relevant for export to North America

Information relevant for export to North America

1)

2)

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
48

Part no.
Article no.

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05; CE marking
E29096
NLDX
012528
3211-04
UL Listed, CSA certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05; CE marking
E29096
NLDX
012528
2411-03, 3211-04
UL Listed, CSA certified

1.1

Contactor combinations
Reversing combinations

1

Individual components of the combination

Spare auxiliary contacts

Contactor Q11

Q11

Part no.

Contactor Q12

Q12

Circuit diagram

Notes

Mechanical
interlock

Part no.

DILEM-10
+ 11DILEM

DILEM-10
+ 11DILEM

33

33

34

34

DILEM-10-G
+ 11DILEM

DILEM-10-G
+ 11DILEM

33

33

+

21

0
22

+

22

21

II

21

22

34

34

14

13

I
14

13
14

14

Q12

Q11

13

13
22

Q12

22

Q11
21
A1

21
A1

Q11

Q12

DILM7-01
+ DILA-XHI20

63

63

64

64

DILM7-01
+ DILA-XHI20

DILM7-01
+ DILA-XHI20

63

63

64

64

DILM9-01
+ DILA-XHI20

DILM9-01
+ DILA-XHI20

63

63

DILM7-01
+ DILA-XHI20

+

21

0

1

22

+

22

21

II

+

A2

A2

(-)N

22

21
13

14

I

13

14
54

64

64
63

DILM9-01
+ DILA-XHI20

DILM9-01
+ DILA-XHI20

63

64

64

DILM12-01
+ DILA-XHI20

DILM12-01
+ DILA-XHI20

63

63

64

64

DILM12-01
+ DILA-XHI20

DILM12-01
+ DILA-XHI20

63

63

64

64

DILM17-01
+ DILA-XHI20

DILM17-01
+ DILA-XHI20

63

63

64

64

DILM17-01
+ DILA-XHI20

DILM17-01
+ DILA-XHI20

63

63

64

64

DILM25-01
+ DILA-XHI20

DILM25-01
+ DILA-XHI20

63

63

64

64

Q11
53

+

Q12

22

Q12

+

54

21

53
22

Q11

A1

21
A1

A2

Reversing contactors

A2

+
+

1

5

3

63

63

64

64

DILM32-01
+ DILA-XHI20

DILM32-01
+ DILA-XHI20

63

63

64

64

DILM32-01
+ DILA-XHI20

DILM32-01
+ DILA-XHI20

63

63

64

64

DILM40
+ DILM150-XHI11

DILM40
+ DILM150-XHI11

–

DILM50
+ DILM150-XHI11

DILM50
+ DILM150-XHI11

–

DILM65
+ DILM150-XHI11

DILM65
+ DILM150-XHI11

–

–

1

3

5

2

4

6

Q12
2

4

6

+
+
U

DILM25-01
+ DILA-XHI20

Chapter 1.2

52

Q11

DILM25-01
+ DILA-XHI20

Page

Accessories

Q12

Q11

Accessories
1 Overload relay

M1

+

V

W

M
3

DIULM7/21 to DIULM65/11 with mechanical
interlock

+
+
+

21

0
22

–

+

22

21

II

21

22
14

–

+

13

I
14

13
14

Q12

Q11

13

13
22

Q12

22

Q11
21
A1

21
A1

Q11
(-)N

14

Q12
A2

A2

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

49

1.1
1

Contactor relays, contactors
Suppressor circuit

Ordering
DILM...-XSP...
Suppressor circuits
Voltage

For use with

Circuit symbol

Us

Part no.
Article no.

V
RC suppressors

24 - 48 AC
110 - 240 AC

DILM7 - DILM15
DILMP20
DILA

A1

A2

240 - 500 AC
24 - 48 AC
110 - 240 AC

DILM17 - DILM32
DILK12 - DILK25
DILL…
DILMP32 - DILMP45

240 - 500 AC
24 - 48 AC
110 - 240 AC

DILM40 - DILM95
DILK33 - DILK50
DILMP63 - DILMP200

240 - 500 AC
Varistor
suppressors

24 - 48 AC
48 - 130 AC

DILM7 - DILM15
DILMP20
DILA

A1

A2

130 - 240 AC
240 - 500 AC
24 - 48 AC
48 - 130 AC

DILM17 - DILM32
DILK12 - DILK25
DILL…
DILMP32 - DILMP45

130 - 240 AC
240 - 500 AC
24 - 48 AC
48 - 130 AC

DILM40 - DILM95
DILK33 - DILK50
DILMP63 - DILMP200

130 - 240 AC
240 - 500 AC

DILM12-XSPR48
281199
DILM12-XSPR240
281200

50

Std. pack

Notes

10 Off

For AC operated contactors 50 - 60 Hz.
DC operated contactors and DILM115 and
DILM150 have an integrated suppressor.
Note drop-out delay.

10 Off

DILM12-XSPR500
281201

10 Off

DILM32-XSPR48
281202
DILM32-XSPR240
281203
DILM32-XSPR500
281204

10 Off

DILM95-XSPR48
281205
DILM95-XSPR240
281206
DILM95-XSPR500
281207

10 Off

DILM12-XSPV48
281208
DILM12-XSPV130
281209
DILM12-XSPV240
281210

10 Off

DILM12-XSPV500
281211

10 Off

DILM32-XSPV48
281212
DILM32-XSPV130
281213

10 Off

DILM32-XSPV240
281214
DILM32-XSPV500
281215

10 Off

DILM95-XSPV48
281216
DILM95-XSPV130
281217

10 Off

DILM95-XSPV240
281218
DILM95-XSPV500
281219

10 Off

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

Price
See price
list

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
227038
3211-07
UL Listed, CSA certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

10 Off
10 Off

10 Off
10 Off

10 Off
10 Off

10 Off

10 Off

10 Off

10 Off

For AC operated contactors 50 - 60 Hz.
DC operated contactors and DILM115 and
DILM150 have an integrated suppressor.
Note drop-out delay.

Contactor relays, contactors
Suppressor circuit

1.1

Ordering

1

DILM...-XSP...
Suppressor circuits
Voltage

For use with

Circuit symbol

DILM7 - DILM15
DILMP20
DILA

A1

Us

Std. pack

Notes

DILM12-XSPVL48
281220
DILM12-XSPVL240
281221

10 Off

For AC operated contactors 50 - 60 Hz.
DC operated contactors and DILM115 and
DILM150 have an integrated suppressor.
Note drop-out delay.

DILM32-XSPVL48
281222

10 Off

DILM32-XSPVL240
281223
DILM95-XSPVL48
281224
DILM95-XSPVL240
281225

10 Off

DILM12-XSPD
101672

10 Off

Part no.
Article no.

V
Varistor
suppressors
with integrated
LED

24 - 48 AC
130 - 240 AC
24 - 48 AC
130 - 240 AC
24 - 48 AC
130 - 240 AC

Diode suppressor

12 - 250 DC

A2

DILM17 - DILM32
DILK12 - DILK25
DILL…
DILMP32 - DILMP45
DILM40 - DILM95
DILK33 - DILK50
DILMP63 - DILMP200
DILM7 - DILM15
DILMP20
DILA

A1

A2

Price
See price
list

10 Off

10 Off
10 Off
DC operated contactors.
Prevention of negative switch-off voltage
when the contactor is used together with
a safety PLC.

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
227038
3211-07
UL Listed, CSA certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

51

1.1

Contactor relays, contactors
Accessories

1 DILM...-XDILM..-XVB, DILM..-XMV
For use with

Part no.
Article no.

Price
See price
list

Std. pack

Notes

Information relevant for export to North America

50 Off

–

Product Standards

Mechanical interlocks
For mechanically linking contactors
in combinations
0 mm distance between contactors.
DILM7 - DILM72
DILA

DILM32-XVB
281227

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
DILM80 - DILM170

DILM150-XVB
281226

10 Off

–

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E36332
NLRV
012528
3211-05
UL Listed, CSA certified
IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E29184
NKCR
012528
3211-03
UL Listed, CSA certified

Mechanical interlocks
DILM7 - DILM15
DILMP20
DILA

DILM12-XMV
281196

1 Off

DILM17 - DILM38

DILM32-XMV
281197

1 Off

DILM40 - DILM72

DILM65-XMV
281198

1 Off

DILM80 - DILM170

DILM150-XMV
240081

For two contactors with AC or DC
operation arranged vertically or
horizontally.
Distance between contactors 0 mm,
including contactor connector
Mechanical lifespan 2.5 x 106
operations.
DILM 150-XMV including mounting
plate for contactors.
Additional auxiliary contact
modules possible.
36

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Product Standards

1 Off

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
DILM185A,
DILM225A,
DILM250,
DILM300A,
DILM400,
DILM500,
DILM570

DILM500-XMV
208289

DILM580,
DILM650
DILM750,
DILM820
DILM1000

DILM820-XMV
208288

1 Off

1 Off

For contactors with the same or
different magnet systems mounted
horizontally or vertically, mechanical
lifespan 5 x 10 6 operations. No
auxiliary contact permitted between
mechanical interlock and contactor.
Combination only with consecutive
installation sizes or DILM185A DILM570.
For contactors with the same or
different magnet systems mounted
horizontally or vertically, mechanical
lifespan 5 x 10 6 operations. No
auxiliary contact permitted between
mechanical interlock and contactor.
DILM820-XMV consists of interlock
element and mounting plate.

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E29096
NLDX
012528
2411-03
UL Listed, CSA certified
IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E29096
NLDX
012528
2411-03,3211-04
UL Listed, CSA certified
IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E29096
NLDX
012528
2411-03
UL Listed, CSA certified
IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E29184
NKCR
012528
3211-04
UL Listed, CSA certified
IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E29184
NKCR
012528
3211-04
UL Listed, CSA certified

Set of spare parts for
mechanical interlock
Ball for mechanical interlock, incl.
contactor connector.
–
DILM80 - DILM170

52

DILM150-XMVE
107020

1 Off

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

UL/CSA certification not required

Contactor relays, contactors
Accessories

1.1

DILM...-XP1, DILM...-XS1
For use with

1
Circuit
symbol

Part no.
Article no.

Price
See price
list

Std. pack

Notes

Information relevant for export to North
America

4th pole can be
broken off
AC-1 current carrying
capacity of the open
contactor increases
by a factor of 2.5
Protected against
accidental contact in
accordance with VDE
0106 Part 100
A cover is included
with DILM185-XP1 for
protection against
accidental contact.
Connection cross
section for DILM..XP1 Technical data

Product Standards

Paralleling links for main contacts
Consisting of 2 paralleling links
DILM7 - DILM15

DILM12-XP1
281193

5 Off

DILM17 - DILM32

DILM32-XP1
281194

5 Off

DILM40 - DILM72

DILM65-XP1
281195

1 Off

DILM80 - DILM170

DILM150-XP1
284769

1 Off

DILM185A

DILM185-XP1
208292

1 O ff

DILM7 - DILM15

DILM12-XS1
281190

20 Off

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No.14-05; CE marking
E29096
NLDX
012528
3211-03
UL Listed, CSA
certified

–

Star-point bridges
• Designed as toolless plug
connection
• Use as DILA-XHIT...
contactor auxiliary
contact
38

Product Standards

Product Standards

Product Standards

DILM17 - DILM32

DILM32-XS1
281191

20 Off

DILM40 - DILM72

DILM65-XS1
281192

10 Off

• Use as DILA-XHIT...
contactor auxiliary
contact
38
–

DILM80 - DILM170

DILM150-XS1
284768

5 Off

–

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
DILM185A - DILM400

DILM500

DILM400-XS1
208291

DILM500-XS1
208290

1 Off

1 Off

A cover is included
for protection against
accidental contact.

A cover is included
for protection against
accidental contact.

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Product Standards
UL File No.
UL CCN
NA Certification

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No.14-05; CE marking
E36332
NLRV
012528
3211-05
UL Listed,
CSA certified
IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No.14-05; CE marking
E36332
NLRV
012528
3211-04
UL Listed,
CSA certified
IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No.14-05; CE marking
E36332
NLRV
012528
3211-03
UL Listed,
CSA certified
IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No.14-05; CE marking
E36332
NLRV
012528
3211-03
UL Listed,
IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No.14-05; CE marking
E29096
NLDX
UL Listed

53

1.1

Contactor relays, contactors
Accessories

DILM...-XSL
Star-delta wiring kit

1

Main current wiring for star-delta combination Including star-point bridge

54

For use with

Part no.
Article no.

Price
See price
list

Std. pack

Notes

Information relevant for export to North
America

DILM7/9/12/15
mains contactors
DILM7/9/12/15 delta
contactors
DILM7/9/12/15
star contactors

DILM12-XSL
283130

1 Off

• Designed for tool-less plug
connection
• Use as DILA-XHIT...
contactor auxiliary contact
38
The following control cables are
integrated in addition to electrical
interlock:
• Q13: A1 - Q15: 21
• Q13: 21 - Q15: A1
• Q13: A2 - Q15: A2
Consists of the following
connection bridges:
• Mains - delta contactors
• Delta - star contactors
• Star-point bridge

Product Standards

DILM17/25/32
mains contactors
DILM17/25/32 delta
contactors
DILM17/25/32 star
contactors

DILM32-XSL
283131

DILM40/50/65
mains contactors
DILM40/50/65 delta
contactors
DILM40/50/65 star
contactors
DILM 80/95 mains
contactors
DILM80/95 delta
contactors
DILM50/65 star
contactors

DILM65-XSL
101058

1 Off

DILM95-XSL
101486

1 O ff

–

DILM 115/150 mains
contactors
DILM115/150 delta
contactors
DILM80/95/115 star
contactors

DILM150-XSL
101487

1 Off

Product Standards

DILM 185/225 mains
contactors
DILM185/225 delta
contactors
DILM115/150 star
contactors

DILM225-XSL
101488

1 Off

CSA File No.
CSA Class No.
NA Certification

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
1 O ff

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

–

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
012528
3211-05
UL Listed, CSA certified

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E36332
NLRV
012528
3211-04
UL Listed, CSA certified

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E36332
NLRV
012528
2411-03,3211-04
UL Listed, CSA certified

1.1

Contactor relays, contactors
Accessories

DILM...-XRL, DILM...XIP2X
Reversing starter wiring kits

1

Main current wiring for reversing combinations
For use with

Part no.
Article no.

DILM7
DILM9
DILM12

DILM12-XRL
283108

Price
See price
list

Std. pack

Notes

Information relevant for export to North
America

1 Off

Product Standards

DILM17
DILM25
DILM32
DILM40
DILM50
DILM65

DILM32-XRL
283109

1 Off

• Designed for tool-less
plug connection
• As auxiliary contact
DILA-XHIT...use
38
The following control cables
are integrated in addition to
electrical interlock:
• Q11: A1 - Q12: 21
• Q11: 21 - Q12: A1
• Q11: A2 - Q12: A2
–

DILM65-XRL
101057

1 Off

–

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

DILM80
DILM95
DILM115
DILM150

DILM150-XRL
101681

1 Off

–

Product Standards

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

Product Standards

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No.14-05;CE marking
E36332
NLRV
012528
3211-05
UL Listed, CSA
certified
IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No.14-05; CE marking
E36332
NLRV
012528
3211-04
UL Listed, CSA
certified
IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No.14-05; CE marking
E36332
NLRV
012528
2411-03, 3211-04
UL Listed, CSA
certified

DILM...-XRL, DILM...XIP2X
IP2X cover set
For use with

Part no.
Article no.

DILM17
DILM25
DILM32
DILM38
DILMP32
DILMP45

Price
See price
list

Std. pack

Notes

Information relevant for export to North
America

DILM32-XIP2X
118855

1 Off

Each cover set consists of
two three-pole and two
single-pole covers.

UL/CSA certification not required

DILM40
DILM50
DILM65
DILM72
DILMP63
DILMP80

DILM65-XIP2X
106491

8 Off

2 covers are required per
phase
The cover set consists of
8 covers

UL/CSA certification not required

DILM80
DILM95
DILM115
DILM150
DILM170
DILMP125
DILMP160
DILMP200
ZB150

DILM150-XIP2X
106492

8 Off

UL/CSA certification not required

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

55

1.1

Contactor relays, contactors
Accessories

DILM12-XDSBS
Three-phase commoning links

1

Protected against accidental contact, short-circuit proof, Ue = 690 V, Iu = 35 ACan be extended by rotating by mounting

–

For use with

Part no.
Article no.

DILM7
DILM9
DILM12
DILM15
DILM7
DILM9
DILM12
DILM15
DILM7
DILM9
DILM12
DILM15

Price
See price
list

Std. pack

Notes

Information relevant for export to North
America

DILM12-XDSB0/3
240084

5 Off

Suitable for 3 contactors.
Length 112 mm

Product Standards

DILM12-XDSB0/4
240085

5 Off

Suitable for 4 contactors.
Length 157 mm

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

DILM12-XDSB0/5
240086

5 Off

Suitable for 5 contactors.
Length 202 mm

Std. pack

Notes

Information relevant for export to North
America

5 Off

For three-phase commoning
link, protected against
accidental contact,
U e = 690 V, I u = 35 A.
Terminal capacities:
Stranded 2.5…16 mm 2
Flexible with ferrule
2.5…16 mm 2
AWG14…8

Product Standards

Std. pack

Notes

Information relevant for export to North
America

1 Off

For top-hat rail 75 mm

Product Standards

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E36332
NLRV
012528
2411-03
UL Listed, CSA certified

DILM12-XDSBS
Incoming connection block
For use with

Part no.
Article no.

DILM7
DILM9
DILM12
DILM15

DILM12-XEK
240083

Price
See price
list

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E36332
NLRV
012528
2411-03
UL Listed, CSA certified

DILM12-XDSBS
Adapter plate
Enables clipping on of switches on to DIN rails

56

For use with

Part no.
Article no.

DILM80
DILM95
DILM115
DILM150
DILM170

NZM2-XC75
260215

Price
See price
list

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 489;
CSA-C22.2 No.14-05;
CE marking
E140305
DIHS
022086
1437-01
UL Listed, CSA certified

Contactor relays, contactors
Electronic timer modules

1.1

DILM32-XTE
Electronic timer modules
For use with

On-delayed, Cannot be
combined with top
mounting auxiliary
contacts Incl.
suppressor circuits

Off-delayed, auxiliary
voltage-free Cannot be
combined with top
mounting auxiliary
contactsIncl.
suppressor circuits

1
Std. pack

Notes

DILM32-XTEE11(RA24)
101440
DILM32-XTEE11(RAC130)
101441
DILM32-XTEE11(RAC240)
101442

1 Off

Time range can be
selected
0.05 s...1 s
0.5 s...10 s
5 s...100 s

DILM32-XTED11-1(RA24)
105210

1 Off

Time range
0.05 s...1 s

DILM32-XTED11-10(RA24)
104943
DILM32-XTED11-100(RA24)
104946
DILM32-XTED11-1(RAC130)
105211
DILM32-XTED11-10(RAC130)
104944

1 Off

100 … 130 V AC

DILM32-XTED11-100(RAC130)
104947

1 Off

Time range
0.5 s...10 s
Time range
5 s...100 s
Time range
0.05 s...1 s
Time range
0.5 s...10 s
Time range
5 s...100 s

200 … 240 V AC

DILM32-XTED11-1(RAC240)
105212
DILM32-XTED11-10(RAC240)
104945
DILM32-XTED11-100(RAC240)
104948

1 Off

1 Off

Time range
5 s...100 s

DILM32-XTEY20(RA24)
101446
DILM32-XTEY20(RAC130)
101447
DILM32-XTEY20(RAC240)
101448

1 Off

Changeover time
1...30 s
50 ms changeover
delay
Sample circuit
Page 92

24 V AC/DC
100 … 130 V AC

DILM7 - DILM32
DILMP20
DILMP32-DILMP45
DILA

Circuit symbol

Part no.
Article no.

A1

57

65

A2

58

66

200 … 240 V AC

24 V AC/DC
24 V AC/DC

DILM7 - DILM32
DILMP20
DILMP32-DILMP45
DILA

A1

57

65

A2

58

66

24 V AC/DC
100 … 130 V AC
100 … 130 V AC

200 … 240 V AC
200 … 240 V AC
For star-delta
applications Cannot be
combined with top
mounting auxiliary
contactsIncl.
suppressor circuits

24 V AC/DC
100 … 130 V AC

DILM7 - DILM32
DILMP20
DILMP32-DILMP45
DILA

A1

57

67

A2

58

68

200 … 240 V AC

Price
See price
list

1 Off
1 Off

1 Off
1 Off
1 Off

1 Off

1 Off
1 Off

Time range
0.05 s...1 s
Time range
0.5 s...10 s

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29184
NKCR
012528
3211-03
UL Listed, CSA certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

57

1.1

Contactor relays, contactors
Accessories

DIL-SWD..., DILM12-XMC
SWD contactor modules

1

SmartWire-DT® module for installation on contactors. One module per contactor

Two digital inputs for potential-free
contacts.
1 electrical interlock for the surface
mounting of reversing starters.
Messages: Contactor switch status,
status of the digital inputs 1 and 2.
Commands: Contactor actuation
Two digital inputs for potential-free
contacts.
1 electrical interlock for the surface
mounting of reversing starters.
1-0-A switch for manual or automatic
operation.
Messages: contactor switching
position, status of the digital inputs 1
and 2, 1-0-A switch position.
Commands: Contactor actuation

For use with

Part no.
Article no.

DILM(C)7… DILM(C)32
DILM38
DILA

DILM(C)7… DILM(C)32
DILM38
DILA

Price
See price
list

Std. pack

Notes

DIL-SWD-32-0011)
118560

5 Off

DIL-SWD-32-0021)
118561

5 Off

• Take into account the max.
current consumption of the
contactor coils per SmartWire-DT®
line.
• A2 terminals must not be
bridged.
• Wiring sets DILM 12-XRL and
PKZM0-XRM12 cannot be used.
• Connection terminals for
electrical interlocking are not
suitable for safety technology.

DIL-SWD..., DILM12-XMC
Wiring set for motor feeder plug
For use with

Part no.
Article no.

PE module with contact
plate

DILM(C)7
DILM(C)9
DILM(C)12
DILM(C)15

Motor plate with PE
module and contact plate

Motor plate with PE
module and contact plate

Price
See price
list

Std. pack

Notes

DILM12-XMCE 2)
121764

5 Off

35x7.5 (15) mm mounting rail (as per
DIN EN 60715) with PE function required.
For connection of:
PE 0.75 – 4 mm²

DILM(C)7
DILM(C)9
DILM(C)12
DILM(C)15

DILM12-XMCP/E 2)
121769

1 Off

35x7.5 (15) mm mounting rail (as per
DIN EN 60715) with PE function required.
For connection of:
L1, L2, L3, PE 0.75 – 2.5 mm²

PKZM0/PKE + DILM(C)7
PKZM0/PKE + DILM(C)9
PKZM0/PKE + DILM(C)12
PKZM0/PKE + DILM(C)15
MSC-D(E)-…-M7…
MSC-D(E)-…-M9…
MSC-D(E)-…-M15…

DILM12-XMCP/T2)
121770

1 Off

For connection of:
L1, L2, L3, PE 0.75 – 2.5 mm²

Information relevant for export to North America

1) NA Certification
2) Product Standards
NA Certification

58

Request filed for UL and CSA
IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
Request filed for UL and CSA

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Contactor relays, contactors
Accessories

1.1

DILM...-X...

1
For use
with

Part no.
Article no.

Price
See price
list

Std. pack

Notes

Information relevant for export to
North America

4 Off

• Tool-less version using
tool-less plug
connection
• RC suppressor
• Ambient temperature
-25…+60 °C, open.
• Insulated material,
difficult to ignite
according to UL 94.
• Weight = 0.05 kg.
• UL/CSA approval
applied for

Product Standards

Motor suppressor module
Can be used at 380…575 V 50/60 Hz.
DILM7 DILM15

DILM12-XMSM
109399

UL File No.
UL CCN
NA Certification

IEC/EN 60947-4-1;
UL 508; CE marking
E300273
NMTR2
UL Listed

Test block
Suitable for switching on contactor off-load
DILM32-XMAN
110955

1 Off

–

U L /C S A c e r tific a tio n n o t r e q u ir e d

DILM12-XPBC
109400

4 O ff

–

–

DILM17
DILM25
DILM32
DILM38
DILMP32
DILMP45

DILM32-XSPLW24
112419

1 Off

Installed in a suppressor
circuit enclosure.
Required when using
special PLC outputs for
actuation, e.g.: Beckhoff
safety controllers.

Product Standards

DILM80
DILM95
DILM115
DILM150
DILM170

DILM150-XZK
104486

Can be fitted on every
main terminal of the contactor.
Connection options:
maximum 2 x 4 mm² solid
maximum 2 x 2.5 mm²
flexible with ferrule

Product Standards

Connection options:
round conductors,
flexible and stranded,
ribbon cables.

Product Standards

DILM7 DILM38
DILA

Printed board contact
For the adaption of a control circuit on a
printed-circuit board
DILM7 DILM15
DILA

Load resistor
For DC contactors in order to increase
power consumption

CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1;
CSA-C22.2 No.14-05;
CE marking
225135
3211-07
CSA certified

Extension terminals
10 Off

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No.14-05;CE marking
E29184
NKCR
012528
2411-03, 2411-04
UL Listed, CSA certified

Cable terminal block
With control circuit terminal
Consisting of three flat ribbon terminals
DILM250
DILM300A
DILM400

DILM400-XKU-S
208293

1 Off

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No.14-05;CE marking
E29184
NKCR
012528
3211-04
UL Listed, CSA certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

59

1.1

Contactor relays, contactors
Accessories

DILM...-XK...
Flat strip conductor terminal kit

1

With control cable connection
For use
with

Part no.
Article no.

DILM580
DILM650
DILM750
DILM820

DILM820-XKB-S
208295

Price
See price
list

Std. pack

Notes

1 Off

Connection options:
ribbon cables

Information relevant for export to
North America

DILM...-XK...
Connection terminal sets for North America
Consist of three individual terminals
Conductor
material

Cross-section X

For use
with

Part no.
Article no.

DILM500/22

DILM500-XK-CNA
232192
DILM820-XK-CNA
232194

number of
cores
mm²
Copper,
aluminum
Copper,
aluminum

60

2 x (AWG4 …
MCM500)
4 x (AWG2 …
MCM500)

DILM580/22
DILM650/22
DILM750/22
DILM820/22

Price
See
price list

Std. pack

Notes

Information relevant for export to North America

1 Off

Including cover
With control
cable connection

Product Standards

1 Off

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05;
CE marking
E29184
NKCR
012528
3211-04
UL Listed, CSA certified

Contactor relays, contactors
Accessories

1.1

DILM...-XHB, DILM...-XAB
Description

1

For use with

Part no.
Article no.

DILM32-XTE…

Price
See price
list

Std. pack

Notes

Information relevant for export to
North America

DILM32-XTEPLH
101449

1 O ff

–

–

Labelling with
laser printer,
plotter, film
plotter, copier

XGKE-GE
207517

25 Off

1 off = 1 sheet
240 labels per sheet
1 sheet = DIN A4,
Can be split into two DIN A5
sheets

UL/CSA certification not required

DILM185A
DILM225A
DILM250
DILM300A
DILM400
DILM500

DILM225A-XHB
139560
DILM400-XHB
208287

1 Off

To provide terminals with
protection against accidental
contact vertical from the front

UL/CSA certification not required

DILM500-XHB
208286
DILM650-XHB
208285
DILM820-XHB
208284

1 Off

DILM400-XS1

DILM400-XHBS1
101687

1 Off

Can be combined with stardelta wiring kits DILM250-XSL
and DILM400-XSL.

UL/CSA certification not required

DILM7 - DILM38
DILMP32
DILMP45
DILA
DILL
DILM40 DILM170
DILMP63 DILMP200

DILM32-XAB
129538

10 Off

For preventing manual
actuation. Cannot be
combined with additional
surface mounting accessories

UL/CSA certification not required

Sealable shrouds
Transparent

Device labelling, label sheet
7.5 x 17 mm
Colour: yellow HKS 3
( RAL 1018)

Covers
Terminal cover

DILM580
DILM650
DILM750
DILM820,
DILM1000

1 Off

1 Off
1 Off

Shroud for star-point bridge

Auxiliary contact seat cover

DILM150-XAB
121712

10 Off

DILM1000-XSM
125947

1 Off

DILH2600-XSM
125946

1 Off

.

Suppressor circuits for vacuum contactors
(on load side)
DILM580
DILM650
DILM750
DILM820
DILM1000
DILH2000
DILH2200
DILH2600

For damping the cutout
overvoltage when switching
off inductive loads.

NA Certification

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Request filed
for UL and CSA

61

1.1

Contactor relays, contactors
Accessories

DILM...-XSP...
Amplifier module for separate mounting

1

Input with integrated suppressor circuit for overvoltage limitation
Rated operational current
AC-15

Actuating
voltage

Actuating
current

Circuit symbol

For use
with

Part no.
Article no.

...D I L M
DIMLP...
DILL...
DILK...

ETS4-VS3
083094

DC

230 V

400 V

Ie

Ie

Ie

Us

I

A

A

A

V DC

mA

2

2

0.03

24

25

Price
See
price
list

Std. pack

Information relevant for export to
North America

1 Off

Product Standards

220 V

21

13

22

14

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

Notes

IEC/EN
60947-4-1;
UL 508;
CSA-C22.2
No.14-05;
CE marking
E36332
NLRV
012528
2411-03,
3211-04
UL Listed,
CSA certified

Contactor coils with rated operational current > 2 A must be actuated via the DILER-G mini contactor relay.
Rated operational current DC:
Making and breaking conditions DC-13, time L/R 300ms

DILM...-XSP...
Individual coils
DC voltage
For use with

Part no.
Article no.

DILM17
DILM25
DILM32
DILM38
DILM40
DILM50
DILM65
DILM72

DILM32-XSP(RDC24)1)
281155

DILM80
DILM95
DILM115
DILM150
DILM170
DILM185A
DILM225A
Notes

AC voltage
Prices
See price
list

Std. pack

Notes

DILM32-XSP(230V50Hz,240V60Hz)
281141

1 Off

For additional actuating
voltages
Page 75

DILM65-XSP(RDC24)1)
281185

DILM65-XSP(230V50Hz,240V60Hz)
281171

1 Off

DILM95-XSP(RDC24)1)
230080
DILM150-XSP(RDC24)1)
230115

DILM95-XSP(230V50Hz,240V60Hz)
230062
DILM150-XSP(RAC240)1)
230112

1 Off

DILM225A-XSP(RDC24)1)
139568

DILM225A-XSP(RAC240)1)
139565

1 Off

1)

Incl. electronic module

Part no.
Article no.

Price
See price
list

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

62

1 Off

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking
E29096
NLDX
012528
2411-03, 3211-04
UL Listed, CSA certified

1.1

Contactor relays, contactors
Accessories

DILM...-XSP/E...
Electronic modules including coils

1

DC voltage

AC voltage

For use with

Part no.
Article no.

Price
See price
list

Part no.
Article no.

DILM250
DILM300A
DILM400
DILM500
DILM580
DILM650
DILM750
DILM820
DILM1000

DILM250-XSP/E(RA250)1)
208252
DILM500-XSP/E(RA250)1)
208256
DILM1000-XSP/E(RA250)1)
289145

DILM250-XSP/E(RA250)1)
208252
DILM500-XSP/E(RA250)1)
208256
DILM1000-XSP/E(RA250)1)
289145

DILH1400

–

DILH1400-XSP/E(RAW250)2)
289161

1 Off

DILM250-S
DILM300A-S
DILM400-S
DILM500-S

–

DILM250-S-XSP/E(220-240V50/60Hz) 2)
274202
DILM500-S-XSP/E(220-240V50/60Hz) 2)
274205

1 Off

–

Price
See price
list

Std. pack

Notes

1 Off

For additional actuating
voltages
Page 77

1 Off
1 Off

1 Off

1)

2)

Information relevant for export to North America

Information relevant for export to North America

Product Standards

Product Standards

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508; CSA-C22.2
No.14-05; CE marking
E29096
NLDX
1017510
3211-04
UL Listed, CSA certified

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508; CSA-C22.2
No.14-05; CE marking
E29096
NLDX
012528
3211-04
UL Listed, CSA certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

63

1.1
1

Contactor monitoring devices

Description, ordering

General

Application

Mounting

For safety-related off switching to safety
category 3 and 4 according to EN 954-1,
at present two contactors must be used
in series. Especially with larger
contactors this is an expensive solution.

This is where the CMD can be used. The
function of the CMD is to monitor the
main contacts of a contactor against
welding. For this the control voltage of
the contactor is compared with the state
of the main contacts which is reliably
monitored using a mirror contact (IEC EN
60947-4-1 Annex F). If the coil is deenergized and the contactor does not
drop out the CMD trips the upstream
circuit-breaker/motor protective circuit
breaker/switch-disconnector via a shunt
release.

The CMD can be combined with the
following Eaton components:
• Contactors:
– DILEM
– DILM7 to DILM150
– DILM185(-S) to DILM500(-S):
– DILM580 to DILM1600
– DILH1400 … DILH2000
– SE-1A-PKZ2 and S-PKZ2

Safety
The CMD has a safety-compliant design
so that in safety combinations with a
circuit-breaker/motor protective circuit
breaker/switch disconnector the reliable
switch off in the case of a "welded
contactor" can be guaranteed. In this
application it replaces the series
connection of a second contactor. As a
component it conforms to safety
category 3 according to EN 954-1 and
EN ISO 13849.

For the wiring of the CMD the auxiliary N/C
contact, mirror contact must be according
to IEC/EN 60947-4-1 and the auxiliary N/O
contact must be interlocked and opposing
according to IEC/EN 60947-5-1. Also the
auxiliary N/C contact for the feedback
circuit must have a mirror contact function
according to IEC/EN 60947-4-1.

Auxiliary contact requirements per contactor:

DOL starter
Reversing
starter

CMD

Self
maintaining

Feedback
circuit

1 N/O +
1 N/C
1 N/O +
1 N/C

1S

1B

1S

1B

Ordering
CMD
Part no.
Article no.
CMD contactor monitoring device

64

• Motor-protective circuit-breakers/
circuit-breakers:
– PKZ2 + U-PKZ2(18VDC)
– NZM1 + NZM1-XUVL
– NZM2 + NZM2/3-XUV
– NZM3 + NZM2/3-XUV
– NZM4 + NZM4-XUV
– N1 + NZM1-XUVL
– N2 + NZM2/3-XUV
– N3 + NZM2/3-XUV
– N4 + NZM4-XUV

Price
See Price List

Std. pack

CMD(24VDC)
106170

1 Off

CMD(220-240VAC)
106172

1 Off

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Electrical
interlock

1B

Contactor monitoring devices

1.1

Engineering

1

DOL starter
L1
L2
L3

L0 1

L1
L2
L3

L0 1
-F1

L1 L2 L3

1.13

-Q1
1.14

-Q1

21

-Q11

I> I> I>

22

T1 T2 T3

-K

33

-Q11
34

21

-S1

22

TEST
-S3
1

3

5

2

4

6

-Q11

PE U
-X1

V

W

13

-S2

14

13

14

14

-F2
CMD

A1 L

S21 S22 S13 S14 S31 S32

A2

A1

D1 D2

-Q11

-Q1
A2

U<

D2

L0 2

M
3

-M1

13

22

-Q11

PE

PE

21

L0 2
1
3
5
13
21
33

˜

2
4
6
14
22
34

Reversing starter
L1 L01
L2
L3

L1
L2
L3

L01
-F1

L1 L2 L3

1.13

-Q1

1.14

-Q1

21

21

-Q12

-Q11

I> I> I>
T1 T2 T3

22

-K

22

43

43

-Q12

-Q11

44

21

44

-S1

22

TEST
13

13

1

-Q11

2

3

5

4

6

1

-Q12

2

3
4

13

-S2

5
6

-S3

-Q11

14

14
21

14
21

22

22

31

PE U
-X1

V W PE

31

-Q12

PE

-Q11

32

32

A1

A2

13

22

14

S21 S22 S13 S14 S31 S32

D1 D2

-Q 1

-F3
CMD

A1 L

A2

S21 S22 S13 S14 S31 S32

D1 D2

U<

D2

L02

˜

A1 L

A2

-Q12

A2

-M1

14

-F2
CMD

21

-S4

-Q12

A1

-Q11
M
3

13

L02
1
3
5
13
21
31
43

2
4
6
14
22
32
44

1
3
5
13
21
31
43

2
4
6
14
22
32
44

Switching by safety relay of safety PLC
Signal contact to PLC evaluation

CMD (24VDC)
AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

65

1.1
1

Mini contactor relays, contactor relays
Actuating voltages

Ordering
DILER, DILEEM
AC

DILER-40(...)

DILER-31(...)

DILER-22(...)

DILEEM-10(...)

DILEEM-01(...)

Standard voltages

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

24V 50Hz
48V 50Hz
240V 50Hz
115V 60Hz
42V 50Hz,
48V 60Hz

010094
010190
010478
010270
–

010251
010044
010300
010204
–

010344
010201
010138
010211
–

051604
051603
051602
051598
051612

051629
051628
051627
051624
051637

110V 50Hz,
120V 60Hz
190V 50Hz,
220V 60Hz
220V 50Hz,
240V 60Hz
230V 50Hz,
240V 60Hz

051756

051765

051774

051611

051636

051757

051766

051775

051610

051635

051758

051767

051776

051609

051634

051759

051768

051777

051608

051633

380V 50Hz,
440V 60Hz
400V 50Hz,
440V 60Hz
415V 50Hz,
480V 60Hz
24V 50/60Hz

051760

051769

051778

051607

051632

051761

051770

051779

051606

051631

051762

051771

051780

051605

051630

021924

021594

021704

051596

051621

42V 50/60Hz
110V 50/60Hz
230V 50/60Hz

033459
021961
052725

029869
021624
052509

029433
021871
052508

051595
051592
056674

051620
051618
058771

DC

DILER-40-G(...)

DILER-31-G(...)

DILER-22-G(...)

DILEEM-10-G(...)

DILEEM-01-G(...)

Standard voltages

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

12V DC
24V DC
48V DC
110V DC
220V DC

079711
010223
010255
010287
010303

079761
010157
010205
010253
010269

080728
010042
010346
010043
010091

051644
051643
051642
051640
051639

051649
051650
051648
051646
051645

DILER, DILEEM

Notes

66

1)

To obtain the article number for ordering, read under selected part number and actuating voltage from the table.
Devices with dual-voltage coils are to be ordered under a single article number.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Mini contactor relays, contactor relays
Actuating voltages

1

DILEM
AC

DILEM-10(...)

DILEM-01(...)

DILEM12-10(...)

DILEM12-01(...)

DILEM4(...)

Standard voltages

Article no. 1)
See price list

Article no. 1)
See price list

Article no. 1)
See price list

Article no.1)
See price list

Article no.1)
See price list

24V 50Hz
48V 50Hz
240V 50Hz
115V 60Hz
42V 50Hz,
48V 60Hz
110V 50Hz,
120V 60Hz

010005
010020
010032
010024
051782

010086
010294
010151
010470
051791

127067
–
–
–
–

127083
–
–
–
–

014754
–
014305
–
–

051783

051792

127072

127088

051801

190V 50Hz,
220V 60Hz
220V 50Hz,
240V 60Hz
230V 50Hz,
240V 60Hz
380V 50Hz,
440V 60Hz
400V 50Hz,
440V 60Hz
415V 50Hz,
480V 60Hz
24V 50/60Hz
42V 50/60Hz
110V 50/60Hz
230V 50/60Hz

051784

051793

–

–

–

051785

051794

–

–

051803

051786

051795

–

–

051804

051787

051796

–

–

–

051788

051797

–

–

051806

051789

–

–

–

–

021417
032174
021455
052302

020402
033233
020436
051114

127079
–
127081
127082

127095
–
127097
127098

022044
–
–
052506

DC

DILEM-10-G(...)

DILEM-01-G(...)

DILEM12-10-G(...)

DILEEM12-01-G(...)

DILEM4-G(...)

Standard voltages

Article no. 1)
See price list

Article no. 1)
See price list

Article no. 1)
See price list

Article no.1)
See price list

Article no.1)
See price list

12V DC
24V DC
48V DC
110V DC

079594
010213
010245
010309

079642
010343
010496
010136

–
127132
–
–

–
127137
–
–

079680
012701
–
–

010325

010168

–

–

–

DILEM

220V DC
Notes

1)

To obtain the article number for ordering, read under selected part number and actuating voltage from the table.
Devices with dual-voltage coils are to be ordered under a single article number.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

67

1.1

Contactor relays
Actuating voltages

1 DILA
AC

With screw terminals
DILA-40(...)
DILA-31(...)

DILA-22(...)

With Spring-loaded terminals
DILAC-40(...)
DILAC-31(...)

DILAC-22(...)

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

24V 50Hz
240V 50Hz
110V 50Hz
120V 60Hz
190V 50Hz
220V 60Hz
220V 50Hz
240V 60Hz
230V 50Hz
240V 60Hz

276316
276318
276326

276351
276353
276361

276386
276388
276396

276431
–
276438

276463
–
276470

276495
–
276502

276327

276362

276397

–

–

–

276328

276363

276398

–

–

–

276329

276364

276399

276441

276473

276505

380V 50Hz
440V 60Hz

276330

276365

276400

–

–

–

400V 50Hz
440V 60Hz
24V 50Hz/60Hz

276331

276366

276401

–

–

–

276333

276368

276403

276445

276477

276509

42V 50Hz/60Hz
110V 50Hz/60Hz

276334
276335

276369
276370

276404
276405

–
–

–
–

–
–

220V 50Hz/60Hz
230V 50Hz/60Hz
Special voltages
other than the already
shown normal voltages 2)

276336
276337
See price list

276371
276372
See price list

276406
276407
See price list

–
276449
See price list

–
276481
See price list

–
276513
See price list

...V 50Hz(12-500V)3)
...V 60Hz(12-600V)3)

276341
276342

276376
276377

276411
276412

276453
276454

276485
276486

276517
276518

With screw terminals
DILA-40(...)
DILA-31(...)

DILA-22(...)

With Spring-loaded terminals
DILAC-40(...)
DILAC-31(...)

DILAC-22(...)

Standard voltages

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

24V DC
48V DC
110V DC
220V DC

276344
276345
276347
276348

276379
276380
276382
276383

276414
276415
276417
276418

276456
–
276459
276460

276488
–
276491
276492

276520
–
276523
276524

Special voltages
other than the already
shown normal voltages 2)
...V DC(12-250V)3)

See price list

See price list

See price list

See price list

See price list

See price list

276349

276384

276419

276461

276493

276525

Notes

1)

Standard voltages

DILA
DC

2)
3)

68

The article number is a combination of part no. and operating voltage devices with dual-voltage coils can be
ordered under a single article no.
With non-standard voltages the required actuating voltage from the defined range (...–...V) must be stated.
Minimum order quantity 10 units

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Actuating voltages

DILM
AC

1
DILM7-10
(...)

DILM7-01
(...)

DILM9-10
(...)

DILM9-01
(...)

DILM12-10
(...)

DILM12-01
(...)

DILM15-10
(...)

DILM15-01
(...)

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

24V 50Hz
240V 50Hz
42V 50Hz
48V 60Hz
110V 50Hz
120V 60Hz
190V 50Hz
220V 60Hz

276537
276539
276546

276572
276574
–

276677
276679
276686

276712
276714
–

276817
276819
276826

276852
276854
–

290045
–
–

290080
–
–

276547

276582

276687

276722

276827

276862

290055

290090

276548

276583

276688

276723

276828

276863

–

–

220V 50Hz
240V 60Hz
230V 50Hz
240V 60Hz
380V 50Hz
440V 60Hz
400V 50Hz
440V 60Hz

276549

276584

276689

276724

276829

276864

–

–

276550

276585

276690

276725

276830

276865

290058

290093

276551

276586

276691

276726

276831

276866

–

–

276552

276587

276692

276727

276832

276867

–

–

415V 50Hz
480V 60Hz
24V 50Hz/60Hz
42V 50Hz/60Hz
110V 50Hz/60Hz

276553

–

276693

–

276833

–

–

–

276554
276555
276556

276589
276590
276591

276694
276695
276696

276729
276730
276731

276834
276835
276836

276869
276870
276871

290062
–
–

290097
–
–

220V 50Hz/60Hz
230V 50Hz/60Hz
Special voltages
other than the already shown
normal voltages 2)

276557
276558
See price list

276592
276593
See price list

276697
276698
See price list

276732
276733
See price list

276837
276838
See price list

276872
276873
See price list

–
290066
See price list

–
290101
See price list

...V 50Hz (12 – 600V) 3)

276562

276597

276702

276737

276842

276877

290070

290105

...V 60Hz (12 – 600V) 3)

276563

276598

276703

276738

276843

276878

290071

290106

DILM7-10
(...)

DILM7-01
(...)

DILM9-10
(...)

DILM9-01
(...)

DILM12-10
(...)

DILM12-01
(...)

DILM15-10
(...)

DILM15-01
(...)

Standard voltages

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

24V DC
48V DC
110V DC
220V DC

276565
276566
276568
276569

276600
276601
276603
276604

276705
276706
276708
276709

276740
276741
276743
276744

276845
276846
276848
276849

276880
276881
276883
276884

290073
–
–
–

290108
–
–
–

Special voltages
other than the already shown
normal voltages 2)

See price list

See price list

See price list

See price list

See price list

See price list

See price list

See price list

...V DC (12-250V) 3)

276570

276605

276710

276745

276850

276885

290078

290113

Notes

1)

Standard voltages

DILM
DC

2)
3)

To obtain the article number for ordering, read under selected part number and actuating voltage from the table.
devices with dual-voltage coils can be ordered under a single article no.
With non-standard voltages the required actuating voltage from the defined range (...–...V)
must be stated.
Minimum order quantity 10 units

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

69

1.1

Contactors
Actuating voltages

1 DILM
AC

DILM17-10
(...)

DILM17-01
(...)

DILM25-10
(...)

DILM25-01
(...)

DILM32-10
(...)

DILM32-01
(...)

DILM38-10(...) DILM38-01(...)

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

24V 50Hz
240V 50Hz
42V 50Hz
48V 60Hz
110V 50Hz
120V 60Hz
190V 50Hz
220V 60Hz

276991
276993
277000

277023
–
–

277119
277121
277128

277151
–
–

277247
277249
277256

277279
–
–

112378
112420
112424

112446
–
–

277001

277033

277129

277161

277257

277289

112425

112454

277002

–

277130

–

277258

–

112426

–

220V 50Hz
240V 60Hz
230V 50Hz
240V 60Hz
380V 50Hz
440V 60Hz
400V 50Hz
440V 60Hz

277003

–

277131

–

277259

–

112427

–

277004

277036

277132

277164

277260

277292

112428

112457

277005

–

277133

–

277261

–

112429

–

277006

277038

277134

277166

277262

277294

112430

112459

415V 50Hz
480V 60Hz
24V 50Hz/60Hz
42V 50Hz/60Hz
110V 50Hz/60Hz
220V 50Hz/60Hz
230V 50Hz/60Hz
Special voltages
other than the already
shown normal voltages 2)
...V 50Hz (24 – 600V)
...V 60Hz (24 – 600V)

277007

–

277135

–

277263

–

112431

–

277008
277009
277010
277011
277012
See price list

277040
–
277042
277043
277044
See price list

277136
277137
277138
277139
277140
See price list

277168
–
277170
277171
277172
See price list

277264
277265
277266
277267
277268
See price list

277296
–
277298
277299
277300
See price list

112432
112433
112434
112435
112436
See price list

112461
–
112463
112464
112465
See price list

277016 7)
277017 7)

277048 7)
277049 7)

277144 7)
277145 7)

277176 7)
277177 7)

277272 7)
277273 7)

277304 8)
277305 8)

112440 7)
112441 7)

112468 7)
112469 7)

Standard voltages

DILM
DC

DILM17-10(...) DILM17-01(...) DILM25-10(...) DILM25-01(...) DILM32-10(...) DILM32-01(...) DILM38-10(...) DILM38-01(...)

Standard voltages

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

RDC 24 3)
RDC 60 4)
RDC 130 5)
RDC 240 6)

277018
277019
277020
277021

277050
277051
277052
277053

277146
277147
277148
277149

277178
277179
277180
277181

277274
277275
277276
277277

277306
277307
277308
277309

112442
112443
112444
112445

112470
112471
112472
112473

Notes

1)
2)
3)
4)
5)
6)
7)
8)

70

To obtain the article number for ordering, read under selected part number and actuating voltage from the table.
devices with dual-voltage coils can be ordered under a single article no.
With non-standard voltages the required actuating voltage from the defined range (...–...V)
must be stated.
24 – 27 V DC
48 – 60 V DC
110 – 130 V DC
200 – 240 V DC
Minimum order quantity 10 units
Minimum order quantity 5 units

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Actuating voltages

DILM

1

AC

DILM40(...)

DILM50(...)

DILM65(...)

DILM72(...)

Standard voltages

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

24V 50Hz
240V 50Hz
42V 50Hz
48V 60Hz
110V 50Hz
120V 60Hz
190V 50Hz
220V 60Hz

277753
277755
277762

277817
277819
277826

277881
277883
277890

–
109183
–

277763

277827

277891

109191

277764

277828

277892

–

220V 50Hz
240V 60Hz
230V 50Hz
240V 60Hz

277765

277829

277893

–

277766

277830

277894

107670

380V 50Hz
440V 60Hz
400V 50Hz
440V 60Hz
415V 50Hz
480V 60Hz
24V 50Hz/60Hz
42V 50Hz/60Hz
110V 50Hz/60Hz
220V 50Hz/60Hz
230V 50Hz/60Hz

277767

277831

277895

–

277768

277832

277896

109195

277769

277833

277897

–

277770
277771
277772
277773
277774

277834
277835
277836
277837
277838

277898
277899
277900
277901
277902

109197
–
109199
109200
109201

Special voltages other than the already shown normal voltages 2)

See price list

See price list

See price list

See price list

...V 50Hz (24 – 600V)
...V 60Hz (24 – 600V)

277778 8)
277779 8)

277842 8)
277843 8)

277906 8)
277907 8)

109205 7)
109206 7)

DC

DILM40(...)

DILM50(...)

DILM65(...)

DILM72(...)

Standard voltages

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

RDC 24 3)
RDC 60 4)
RDC 130 5)
RDC 240 6)

277780
277781
277782
277783

277844
277845
277846
277847

277908
277909
277910
277911

107671
–
–
109209

DILM

Notes

1)

2)
3)
4)
5)
6)
7)

To obtain the article number for ordering, read under selected part number and
actuating voltage from the table.
devices with dual-voltage coils can be ordered under a single article no.
With non-standard voltages the required actuating voltage from the defined range
(...–...V) must be stated.
24 – 27 V DC
48 – 60 V DC
110 – 130 V DC
200 – 240 V DC
Minimum order quantity 10 units

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

71

1.1

Contactors
Actuating voltages

1 DILM

DILM

AC

DILM80
(...)

DILM95
(...)

DILM115
(...)

DILM150
(...)

DILM170
(...)

DILM185A/ DILM225A/
22(...)
22(...)

Article no.1)
See price
list

Article no.1)
See price
list

Standard
voltages

Article no. 1)
See price
list

Article no. 1)
See price
list

Article no. 1)
See price
list

Article no. 1)
See price
list

Article no. 1)
See price
list

24 V 50 Hz
240V 50Hz
42V 50Hz
48V 60Hz
110V 50Hz
120V 60Hz
190V 50Hz
220V 60Hz

235904
235910
239394

239467
239469
239476

RAC 247)
RAC 488)
RAC 1209)

239545
239546
239547

239585
239586
239587

107010
107011
107012

139534
139535
139536

139544
139545
139546

239399

239477

RAC 24010)

239548

239588

107013

139537

139547

239400

239478

RAC 44011)

239549

239589

107014

139538

139548

220V 50Hz
240V 60Hz
230V 50Hz
240V 60Hz
380V 50Hz
440V 60Hz

239401

239479

RAC 50012)

239550

239590

107015

139539

139549

239402

239480

239403

239481

400V 50Hz
440V 60Hz
415V 50Hz
480V 60Hz
24V 50Hz/60Hz
42V 50Hz/60Hz
110V 50Hz/60Hz
220V 50Hz/60Hz
230V 50Hz/60Hz
Special voltages
other than the already
shown normal voltages 2)
...V 50Hz (24 – 600V) 13)
...V 60Hz (24 – 600V) 13)

239404

239482

DILM115
(...)

DILM150
(...)

DILM170
(...)

DILM185A/ DILM225A/
22(...)
22(...)

239405

239483

239406
239407
239408
239409
239410
See price
list

239484
239485
239486
239487
239488

Standard
voltages

Article no. 1)
See price
list

Article no. 1)
See price
list

Article no. 1)
See price
list

Article no. 1)
See price
list

Article no. 1)
See price
list

RDC 243)
RDC 604)
RDC 1305)
RDC 2406)

239555
239560
239567
239572

239591
239592
239593
239594

107016
107017
107018
107019

139540
139541
139542
139543

139550
139551
139552
139553

Notes

1)

Standard voltages

239414
239415

list

AC

DILM
DC

239504
239509
2)

DILM
DC

3)
4)

DILM80
(...)

DILM95
(...)
Article no.1)
See price
list

8)

Standard voltages

Article no.1)
See price
list

RDC 243)
RDC 604)

239416
239417

239510
239511

12)

RDC 1305)
RDC 2406)

239418
239419

239512
239513

5)
6)
7)

72

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

9)
10)
11)
13)

The article no. results from combining the part no. and the
actuating voltage.
Devices with dual-voltage coils must be ordered under a single
article no.
With non-standard voltages the required actuating voltage from
the defined range
(...–...V) must be stated.
24 - 27 V DC
48 – 60 V DC
110 - 130 V DC
200 - 240 V DC
24 V 50/60 Hz
42 – 48 V 50/60 Hz
100 – 120 V 50/60 Hz
190 – 240 V 50/60 Hz
380 – 440 V 50/60 Hz
480 – 500 V 50/60 Hz
Minimum order quantity 5 units

1.1

Contactors
Actuating voltages

DILM
AC

1
DILMC7-10
(...)
Article no.1)
See price list

DILMC7-01
(...)
Article no.1)
See price list

DILMC9-10
(...)
Article no.1)
See price list

DILMC9-01
(...)
Article no.1)
See price list

DILMC12-10
(...)
Article no.1)
See price list

DILMC12-01
(...)
Article no.1)
See price list

DILMC15-10
(...)
Article no.1)
See price list

DILMC15-01
(...)
Article no.1)
See price list

277379
277386

277411
277418

277443
277450

277475
277482

277507
277514

277539
277546

293938
293908

293933
293943

277389

277421

277453

277485

277517

277549

293911

293946

277393
277397
See price list

277425
277429
See price list

277457
277461
See price list

277489
277493
See price list

277521
277525
See price list

277553
277557
See price list

293915
293919
See price list

293950
293954
See price list

277401
277402

277433
277434

277465
277466

277497
277498

277529
277530

277561
277562

293923
293924

293958
293959

DILMC7-10
(...)
Article no.1)
See price list

DILMC7-01
(...)
Article no.1)
See price list

DILMC9-10
(...)
Article no.1)
See price list

DILMC9-01
(...)
Article no.1)
See price list

DILMC12-10
(...)
Article no.1)
See price list

DILMC12-01
(...)
Article no.1)
See price list

DILMC15-10
(...)
Article no.1)
See price list

DILMC15-01
(...)
Article no.1)
See price list

24V DC
110V DC
220V DC
Special voltages
other than the already
shown normal voltages 2)

277404
277407
277408
See price list

277436
277439
277440
See price list

277468
277471
277472
See price list

277500
277503
277504
See price list

277532
277535
277536
See price list

277564
277567
277568
See price list

293926
293929
293930
See price list

293961
293964
293965
See price list

...VDC (12 – 250V) 6)

277409

277441

277473

277505

277537

277569

293931

293966

Standard voltages
24 V 50 Hz
110V 50Hz
120V 60Hz
230V 50Hz
240V 60Hz
24V 50Hz/60Hz
230V 50Hz/60Hz
Special voltages
other than the already
shown normal voltages 2)
...V 50Hz (12 – 600V) 6)
...V 60Hz (12 – 600V) 6)

DILM
DC

Standard voltages

DILM
AC

DILMC17-10 (...)
Article no.1)
See price list

DILMC17-01(...)
Article no.1)
See price list

DILMC25-10 (...)
Article no.1)
See price list

DILMC25-01 (...)
Article no.1)
See price list

DILMC32-10 (...)
Article no.1)
See price list

DILMC32-01 (...)
Article no.1)
See price list

24 V 50 Hz
110V 50Hz
120V 60Hz
230V 50Hz
240V 60Hz
24V 50Hz/60Hz
220V 50Hz/60Hz
230V 50Hz/60Hz
Special voltages
other than the already
shown normal voltages 2)

277570
277578

277600
277608

277630
277638

277660
277668

277690
277698

277720
277728

277581

277611

277641

277671

277701

277731

277585
277588
277589
See price list

277615
277618
277619
See price list

277645
277648
277649
See price list

277675
277678
277679
See price list

277705
277708
277709
See price list

277735
277738
277739
See price list

...V 50Hz (24 – 600V) 6)
...V 60Hz (24 – 600V) 6)

277593
277594

277623
277624

277653
277654

277683
277684

277713
277714

277743
277744

DILMC17-10 (...)
Article no.1)
See price list

DILMC17-01 (...)
Article no.1)
See price list

DILMC25-10 (...)
Article no.1)
See price list

DILMC25-01 (...)
Article no.1)
See price list

DILMC32-10 (...)
Article no.1)
See price list

DILMC32-01 (...)
Article no.1)
See price list

Standard voltages

DILM
DC
Standard voltages
RDC 243)
RDC 1304)
RDC 2405)
Notes

277595
277625
277655
277685
277715
277597
277627
277657
277687
277717
277598
277628
277658
277688
277718
1) The article no. results from combining the part no. and the actuating voltage.
Devices with dual-voltage coils must be ordered under a single article no.
2) With non-standard voltages the required actuating voltage from the defined range (...–...V)
must be stated.
3) 24 - 27 V DC
4) 110 - 130 V DC
5) 200 - 240 V DC
6) Minimum order quantity 10 units

277745
277747
277748

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

73

1.1

Contactors
Actuating voltages

1 DILMP20
AC

Standard voltages

240V 50Hz
110V 50Hz
120V 60Hz
230 V 50Hz
240V 60Hz
24V 50/60Hz
230V 50/60Hz

DILMP20
(…)
Article
no.1)
See
price
list
–
276967

AC

DILMP20
(…)

Standard voltages

See
price
list

Non-standard voltages 2)

See
price
list

RAC 244)
RAC 1205)
RAC 2406)

–
–
–

…V 50Hz (12 – 600V) 3)
…V 60Hz (12 – 600V) 3)

276982
276983

DC

DILMP20
(…)

276970
276974
276978

DILMP20
(…)

Article
no.1)

Article
no.1)
Standard voltages

See
price
list

Non-standard voltages 2)

See
price
list

…V DC (12 – 250V) 3)
276990
24V DC
276985
–
RDC 247)
Notes
1) The article number is a combination of part no. and
actuating voltage
2) For non-standard voltages, state the actuating voltage selected from the range (…–…V) shown.
3) Minimum order quantity: 10 units
4) 24 V 50/60 Hz
5) 100 – 120 V 50/60 Hz
6) 190 – 240 V 50/60 Hz
7) 24 – 27 V DC

74

DILMP20
(…)
Article
no.1)

Article
no.1)

DILMP20
DC

AC

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Actuating voltages

DILM...XSP...
AC

DILM...XSP...
DILM32-XSP DILM65-XSP DILM95(...)
(...)
XSP

1

AC

DILM150-XSP
(...)

DILM225A-XSP
(...)

Standard voltages

Article no.1)
See price
list

Article no.1)
See price list

RAC 247)
RAC 488)
RAC 1209)
RAC 24010)
RAC 44011)
RAC 50012)

230109
230110
230111
230112
230113
230114

139562
139563
139564
139565
139566
139567

DILM150-XSP
(...)

DILM225A-XSP
(...)

Article no.1)
See price
list

Article no.1)
See price
list

Article no.1)
See price
list

Article no.1)
See price
list

Article no.1)
See price
list

24V 50Hz
240V 50Hz
24V 60Hz
115V 60Hz
42V 50Hz
48V 60Hz

281130
281132
281134
281136
281137

281160
281162
281164
281166
281167

229984
229986
229988
229990
229994

110V 50Hz
120V 60Hz
190V 50Hz
220V 60Hz
220V 50Hz
240V 60Hz

281138

281168

230058

281139

281169

230059

DILM...XSP...

281140

281170

230061

DC

230V 50Hz
240V 60Hz
380V 50Hz
440V 60Hz

281141

281171

230062

281142

281172

230063

Standard voltages

400V 50Hz
440V 60Hz
415V 50Hz
480V 60Hz

281143

281173

230064

281144

281174

230065

RDC 243)
RDC 604)

230115
230116

139568
139569

24V 50Hz/60Hz
42V 50Hz/60Hz
110V 50Hz/60Hz
220V 50Hz/60Hz
230V 50Hz/60Hz
Special voltages
other than the already
shown normalvoltages 2)

281145
281146
281147
281148
281149
See price
list

281175
281176
281177
281178
281179
See price
list

230066
230067
230068
230073
230074
See price
list

RDC 1305)
RDC 2406)

230117
230122

139570
139571

Standard voltages

...V 50Hz (24 – 600V)
...V 60Hz (24 – 600V)

Notes

1)

2)

3)
4)
13)

281153
281154 13)

14)

281183
281184 14)

14)

230078
230079 14)

5)
6)
7)
8)
9)
10)

DILM...XSP...
DC

11)

DILM32-XSP DILM65-XSP DILM95(...)
(...)
XSP

Standard voltages

Article no.1)
See price
list

Article no.1)
See price
list

Article no.1)
See price
list

RDC 243)
RDC 604)
RDC 1305)
RDC 2406)

281155
281156
281157
281158

281185
281186
281187
281188

230080
230081
230082
230107

12)
13)
14)

To obtain the article number for ordering, read under
selected part number and actuating voltage from the
table.
Devices with dual-voltage coils are to be ordered
under a single article number.
With non-standard voltages the required actuating
voltage from the defined range (...–...V)
must be stated.
24 – 27 V DC
48 – 60 V DC
110 – 130 V DC
200 – 240 V DC
24 V 50/60 Hz
42 – 48 V 50/60 Hz
100 – 120 V 50/60 Hz
190 – 240 V 50/60 Hz
380 – 440 V 50/60 Hz
480 – 500 V 50/60 Hz
Minimum order quantity 10 units
Minimum order quantity 5 units

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

75

1.1

Contactor for capacitors, contactor
Actuating voltages

1 DILK, DILMF
AC

DILK12-11
(...)

DILK20-11
(...)

DILK25-11
(...)

DILK33-10
(...)

DILK50-10
(...)

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no.1)
See price list

Article no. 1)
See price list

110V 50Hz,
120V 60Hz
190V 50Hz,
220V 60Hz
230V 50Hz,
240V 60Hz

293985

294007

294029

294051

294073

293986

294008

294030

294052

294074

293988

294010

294032

294054

294076

400V 50Hz,
440V 60Hz
Special voltages other than the already
shown normal voltages 2)

293990

294012

294034

294056

294078

See price list

See price list

See price list

293997
293998

294019
294020

294041
294042

–
–

–
–

Standard voltages

…V 50Hz (24 – 600V) 3)
…V 60Hz (24 – 600V) 3)
Notes

1)
2)
3)

76

The article no. results from combining the part no. and the actuating voltage.
Devices with dual-voltage coils must be ordered under a single article no.
With non-standard voltages the required actuating voltage from the defined range (...–...V) must be stated.
Minimum order quantity 10 units

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Actuating voltages

DILM

1

Complete comfort devices

DILM250
/22(...)

DILM300A
/22(...)

DILM400
/22(...)

DILM500
/22(...)

DILM580
/22(...)

DILM650
/22(...)

DILM750
/22(...)

DILM820
/22(...)

DILM1000
/22(...)

Voltage variants

Article no.1) Article no.1) Article no.1) Article no.1) Article no.1) Article no.1) Article no.1) Article no.1) Article no.1)
See price
See price
See price
See price
See price
See price
See price
See price
See price
list
list
list
list
list
list
list
list
list

RDC 48 2)

208199

139554

208207

208211

–

–

–

–

–

RA 110 3)

208200

139555

208208

208212

208215

208218

208221

208224

–

RA 250 4)

208201

139556

208209

208213

208216

208219

208222

208225

267214

RAC 500 5) 6)

208202

139557

208210

208214

208217

208220

208223

208226

–

DILM
Complete units
Standard

DILM250
-S/22(...)

DILM300A
-S/22(...)

DILM400
-S/22(...)

DILM500
-S/22(...)

Voltage variants

Article no.1)
See price
list

Article no.1)
See price
list

Article no.1)
See price
list

Article no.1)
See price
list

110-120V 50/60Hz

274189

139558

274195

274198

220-240V 50/60Hz

274190

139559

274196

274199

DILM
Electronic module, incl. coil, for
comfort model

DILM250-XSP/E(...)

DILM500-XSP/E(...)

DILM1000-XSP/E(...)

Voltage variants

Article no.1)
See price
list

Article no.1)
See price
list

Article no.1)
See price
list

RDC 48 2)

208250

208254

–

110 3)

208251

208255

289146

RA 250 4)

208252

208256

289145

208253

208257

289147

RA

RAC

500 5) 6)

DILM
Electronic module, incl. coil, for
standard model

DILM250-S-XSP/E(...) DILM500-S-XSP/E(...)

Voltage variants

Article no.1)
See price
list

Article no.1)
See price
list

110-120V 50/60Hz

274201

274204

274202

274205

220-240V 50/60Hz
Notes

1)
2)
3)
4)
5)
6)

The article no. results from combining the part no. and the voltage variant.
24 – 48 V DC
48 – 110 V 40 – 60 Hz/48 – 110 V DC
110 – 250 V 40 – 60 Hz/110 – 250 V DC
250 – 500 V 40 – 60 Hz
DC on request

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

77

1.1
1

Contactors
Contact travel diagrams

Engineering
DILM, DILA, DILE, DILH

DILM, DILA, DILE, DILH

The diagrams show the closing and opening travel of the contacts at no load.

The diagrams show the closing and opening travel of the contacts at no load.

N/O

N/O

0

x1

0

x2

0

x1

DILE AC
…DILE
…DDILE

DILE DC
DILE…
…DDILE

DILA-AC
DILA-XHI
DILA-XHIV

DILA-DC
DILA-XHI
DILA-XHIV

DILM7/9 AC
DILM32-XHI, DILA-XHI
DILA-XHIV

DILM7/9 DC
DILM32-XHI, DILA-XHI
DILA-XHIV

AC

DILM32-XHI, DILA-XHI
DILA-XHIV

DILM12/15/P20

DC

DILM32-XHI, DILA-XHI

78

x2

NC

NC

DILM12/15/P20

x1

x2

0

x1

x2

x1

x2

NO early-make

2.0

4.4

2.8

Late-break N/C contact

2.8

4.4

1.9

2.8

N/O

3.2

4.4

NC

0.9

2.8

NC

1.6

4.4

NO early-make

1.06

2.9

N/O

4.0

6.0

x1

x2

N/O

1.9

2.8

NC

0.95

N/O

DILA-XHIV

DILM17/25/32/P32/P45

Late-break N/C contact

1.86

2.9

Auxiliary N/C

1.8

6.0

N/O

1.9

2.8

Auxiliary N/O

3.2

6.0

NC

0.9

2.8

N/O

3.2

6.0

N/O

1.9

2.85

NC

1.6

6.0

NC

0.95

2.85

NO early-make

2.0

6.0

N/O

1.9

2.8

Late-break N/C contact

2.8

6.0

NC

0.9

2.8

N/O

3.2

6.0

NO early-make

1.06

2.9

NC

1.6

6.0

Late-break N/C contact

1.86

2.9

DILM40/50/65/P63/P80

N/O

5.1

7.5

DILM150-XHI

N/O

5.7

7.5

NC

3.9

7.5

NO early-make

3.8

7.5

DILM32-XHI, DILA-XHI
DILA-XHIV

N/O

1.9

2.8

NC

0.9

2.8

N/O

3.3

4.5

NC

1.0

4.5

Late-break N/C contact

5.4

7.5

N/O

3.2

4.5

N/O

5.7

7.5

NC

1.6

4.5

NC

3.9

7.5

NO early-make

2.0

4.5

N/O

5.5

7.5

Late-break N/C contact

2.8

4.5

NC

3.6

7.5

NO early-make

4.1

7.5

Late-break N/C contact

5.0

7.5

DILM150-XHIV

DILM1000-XHI
DILM1000-XHIV

N/O

3.2

4.5

NC

1.6

4.5

N/O

2.1

2.9

DILM80/95/115/150/170/P125/P160/P200

N/O

8.0

11

NC

0.7

2.9

DILM150-XHI

N/O

9.2

11

N/O

2.3

2.9

NC

7.4

11

NC

0.7

2.9

NO early-make

7.3

11

NO early-make

1.1

2.9

Late-break N/C contact

8.9

11
11

DILM150-XHIV

Late-break N/C contact

1.9

2.9

N/O

9.2

N/O

2.3

2.9

NC

7.4

11

NC

0.7

2.9

DILM1000-XHI

N/O

9.0

11

NC

7.1

11

DILM1000-XHIV

NO early-make

7.6

11

Late-break N/C contact

8.5

11
13.0

N/O

3.3

4.5

NC

1.0

4.5

N/O

3.2

4.5

NC

1.6

4.5

DILM185A/225A

N/O

10.0

NO early-make

2.0

4.5

DILM1000-XHI

N/O

10.0

13.0

Late-break N/C contact

2.8

4.5

NC

8.1

13.0

NO early-make

8.4

13.0

Late-break N/C contact

9.5

13.0

N/O

10.1

13.1

N/O

10.3

13.1

NC

8.4

13.1
13.1

N/O

3.2

4.5

NC

1.6

4.5

DILM1000-XHIV

N/O

2.1

2.9

DILM250/300A

NC

0.7

2.9

DILM820-XHI

N/O

2.3

2.9

NC

0.7

2.9

NO early-make

1.1

2.9

Late-break N/C contact

1.9

2.9

DILM400/500/570
DILM820-XHI

N/O

2.3

2.9

NC

0.7

2.9

N/O

3.3

4.5

NC

1.0

4.5

N/O

3.2

4.5

NC

1.6

4.5

NO early-make

2.0

4.5

Late-break N/C contact

2.8

4.5

N/O

3.2

4.5

NC

1.6

4.5

N/O

3.3

4.4

NC

1.0

4.4

N/O

3.2

4.4

NC

1.6

4.4

DILM820-XHIV

DILM820-XHIV

NO early-make

8.7

Late-break N/C contact

9.8

13.1

N/O

8.9

13.1

N/O

10.3

13.1

NC

8.4

13.1
13.1

NO early-make

8.7

Late-break N/C contact

9.8

13.1

DILM580/650/750/820

N/O

2.0

4.1

DILM820-XHI

N/O

7.4

10.5

NC

5.5

10.5

NO early-make

6.0

10.5

Late-break N/C contact

6.8

10.5

DILM1000/1600, DILH1400/2000/2200/2600

N/O

2.0

4.1

DILM820-XHI

N/O

7.4

10.5

NC

5.5

10.5

NO early-make

6.0

10.5

Late-break N/C contact

6.8

10.5

DILM820-XHIV

DILM820-XHIV

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Contactors
Enclosures

1.1

DILE, DILM, SDAINL, DIUL

1

Components
Contactor selection

Part no.
DILE...(-G)(-C)
DILE...(-G)(-C)
DILE...(-G)
DILE...(-G)
DILE...(-G)
DILM7 to DILM15

With top mounting
auxiliary contacts

With side mounting
auxiliary contacts

With overload relay

With parallel
connector

Insulated
enclosures

–

–
–
–
–
–
–

–
–

–
–
–

•
•
–

•
•
•

–

DILM225A
DILM250
DILM300A
DILM400
DILM500

–
–
–
–
–

DILM580
DILM650
DILM750
DILM820
DIULE...
DIULE...

–
–
–
–

•
•
•
•
•
•
•
•
•
•
•
•
•
•

DIULM7 to DIULM12
DIULM17 to DIULM32
DIULM40 to DIULM65
SDAINLEM...

•
•
•
•
•
•

–
–
–
–
–
–

SDAINLM12 to SDAINLM22
SDAINLM30 to SDAINLM65
SDAINLM70 to SDAINLM115

•
•
•

–
–
–

Notes

CI-K small
enclosure
Terminal for CI-K
enclosure
CI enclosure

–

•
–

•
•
•

•
•
–

•

–

–
–
–
–
–
–
–
–

CI-K3-160-TS
CI-K2-145-TS
CI23E-150
CI-K3-160-TS
CI43E-150
CI43E-200
CI44E-200
CI48-250

–
–
–
–
–

–
–
–
–
–

CI48-250
CI48-250
CI48-250
CI48-250
CI48-250

–
–
–
–

–
–
–
–

–
–
–
–
–

–
–
–
–
–
–

CI48-250
CI48-250
CI48-250
CI48-250
CI-K3-125-TS

–
–
–

–
–
–

•

–
–
–

DILM7 to DILM15
DILM17 to DILM32
DILM17 to DILM32
DILM40 to DILM65
DILM40 to DILM65
DILM80 to DILM170
DILM80 to DILM170
DILM185A

–
–
–

CI-K1-95-TS
CI-K2-145-TS
CI-K2-145-AD
CI-K2-100-TS
CI-K2-145-TS
CI-K2-145-TS

–

•
–

•
–

•

•

See catalog
See catalog

Insulated PE, N or
PEN terminal for
enclosure CI-K

CI-K3-125-TS
CI-K4-160-TS
CI23E-150
CI43E-200
CI-K5-125-TS
CI-K5-125-M
CI-K5-160-TS
CI23E-150
CI43E-200
See catalog

See catalog

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

79

1.1
1

Contactors
UL/CSA-approved rating data

for North America
DILE, DILA, DILM
Rating data for approved types

Contactors
GENERAL USE
Maximum
motorrated current
I th
Open/enclosed

Maximum
alternating currentmotor rating
Single-phase

3-phase

115 V
120 V
HP

230 V
240 V
HP

200 V
208 V
HP

230 V
240 V
HP

460 V
480 V
HP

575 V
600 V
HP

A

Part no.

½
¼
½
1
1
2
2
3
3
3
5
7½
7½
10
15
–
–
–
–
–
–
–
–
–
–
–
–

1½
1
1½
2
3
3
5
5
7½
10
15
15
15
25
30
–
–
–
–
–
–
–
–
–
–
–
–

2
1½
3
3

3
2
3
3
5
7½
7½
10
15
20
25
30
40
50
60
60
75
100
125
150
200
200
250
300
350
400
640

5
3
5
10
10
10
15
20
30
40
40
60
75
100
125
125
150
200
250
300
400
400
500
600
700
800
1200

5
5
7½
10
10
15
20
25
40
50
60
75
100
125
125
150
200
250
300
400
500
600
600
700
860
1000
1300

15/13.5
20
20
20
20
35
35
40
55
65
80
125
125
160
160
225
250
350
350
450
550
630
700
800
850
1000
1600

DILEM(4)
DILM7-...(...)
DILM9-...(...)
DILM12-...(...)
DILM15-...(...)
DILM17-...(...)
DILM25-...(...)
DILM32-...(...), DILM38-...(...)
DILM40(...)
DILM50(...)
DILM65(...), DILM70(...)
DILM80(...)
DILM95(...)
DILM115(...)
DILM150(...), DILM170(...)
DILM185(...)
DILM225(...)
DILM250(...)
DILM300(...)
DILM400(...)
DILM500(...)
DILM580(...)
DILM650(...)
DILM750(...)
DILM820(...)
DILM1000(...)
DILM1600(...)

5
7½
10
10
15
20
25
25
40
40
50
60
75
100
125
150
200
200
250
290
350
560

NEMA size

Further approvals 81
• Elevator control
• Refrigeration control
• Resistance air heating
• Incandescent lamps
• Electrical discharge lamps
• Capacitive switching

DILE, DILA, DILM
Approved rating data
UL -File No. E29184
for auxiliary contacts
Pilot Duty
AC

General Use
DC

Part no.

AC
V

A

DC
V

A

DIL(E)EM-10(-01)
DILER-40(31)(22)
...(D)DILE

A600

P300

600

10

250

0.5

DILM7-10(-01)
To
DILM32-10(-01)
DILA...
DILA-XHI...
DILM32-XHI...
DILM...-XHI11-SI
DILM...-XHI11-SA
DILM...-XHI11V-SI

A600

P300

600

15

250

1

A600

P300

600

15

250

1

A600

P600

600

10

–

–

80

00
00
00
0
0
0
1
1
2
2
2
3
3
4
4
4
4
5
5
5
6
6
6
6
6
7
8

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
UL/CSA special purpose rating

for North America

1

DILM, DILMP, DILK
Special purpose rating
DIL

Electrical discharge lamps
(ballast)
480V 60Hz 3phase, 277V
A
60Hz 1phase
600V 60Hz 3phase, 347V
A
60Hz 1phase
Incandescent lamps
(Tungsten)

M7

M9

M12

M15

M17

M25
MP32
MP45

M32

M40
MP63

M50
MP80

M65
M72

M80
MP125

M95
MP160

M115

M150
M170
MP200

12

18

20

20

27

35

40

63

79

88

85

100

136

160

12

18

20

20

27

35

40

63

79

88

85

100

136

160

480V 60Hz 3phase, 277V
60Hz 1phase
600V 60Hz 3phase, 347V
60Hz 1phase
Resistance air heating

A

8

11

14

14

23

32

40

55

74

88

85

100

136

160

A

8

11

14

14

23

32

40

55

74

88

85

100

136

160

480V60Hz 3phase,
277V60Hz 1phase
600V60Hz 3phase,
347V60Hz 1phase
Refrigeration control
(CSA only)
LRA 480V 60Hz 3phase
LRA 600V 60Hz 3phase
480V 60Hz 3phase

A

12

18

20

20

27

35

40

63

79

88

94

110

136

160

A

12

18

20

20

27

35

40

63

79

88

94

110

136

160

A
A
A

60
60
6

60
60
7.5

60
60
10

60
60
10

240
180
23

240
180
32

240
180
40

270
270
26

270
270
36

270
270
45

540
420
63

540
420
70

540
540
84

540
540
90

600V 60Hz 3phase
Elevator control

A

6

7.5

10

10

17

24

30

26

36

45

63

70

84

90

200V 60Hz 3phase

HP (A)

¾ (3.7)

2 (7.8) 2 (7.8)

2 (7.8)

3 (11)

3 (11)

HP (A)

1½ (6.0)

2 (6.8) 2 (6.8)

3 (9.6)

3 (9.6)

5
(15.2)

7½
(25.3)
10 (28)

10
(32.2)
15 (42)

10
20
(32.2) (62.1)
15 (42) 25 (68)

20
(62.1)
30 (80)

30 (92) 30 (92)

240V 60Hz 3phase

7½
(25.3)
7½
(22)

480V 60Hz 3phase

HP (A)

2 (3.4)

60 (77)

75 (96) 75 (96)

3 (3.9)

7½
10 (14) 20 (27) 25 (34)
(11)
10 (11) 15 (17) 20 (22) 30 (32)

30 (40) 50 (65)

HP (A)

7½
(11)
7½
(9.6)

30 (40)

600V 60Hz 3phase

3 (4.8) 7½
(11)
5 (6.1) 7½
(9.6)

40 (41)

40 (41) 60 (62)

75 (77)

100
(99)

40
(104)

40 (104)

100 (99)

DILM, DILMP, DILK
Special purpose rating
DIL

K12

K20

K25

K33

K50

Capacitor Switching
240V 60Hz 3phase

A

18

28

36

48

72

480V 60Hz 3phase
600V 60Hz 3phase

A
A

18
14.4

28
28

36
38.4

48
48

72
72

240V 60Hz 3phase
480V 60Hz 3phase
600V 60Hz 3phase

kvar
kvar
kvar

7.5
15
15

12
20
30

15
30
40

20
40
50

30
60
75

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

81

1.1
1

Contactors
UL/CSA short circuit current rating

for North America
DILM
Short circuit current rating (SCCR)
Contactor

Basic Rating
Max. fuse
kA
A

Max. CB
A

480 V High Fault
Max. fuse
kA
A

kA

Max. CB
A

600 V High Fault
Max. fuse
kA
A

kA

Max. CB
A

DILM7-…(…)
DILM9-…(…)
DILM12-…(…)

5
5
5

45
45
45

60
60
60

100
100
100

20 Class J
20 Class J
20 Class J

-

Fuse only
Fuse only
Fuse only

30
30
30

25
25
25

-

Fuse only
Fuse only
Fuse only

DILM15-…(…)
DILM17-…(…)

5
5

45
125

60
125

100

20 Class J
70 Class J

10

Fuse only
50

30
10

25
125

10

Fuse only
50

DILM25-…(…)
DILM32-…(…)
DILM38-…(…)
DILM40(…)
DILM50(…)
DILM65(…)

5
5
5
10
10
10

125
125
125
250
250
250

125
125
125
250
250
250

100
100
100
100
100
100

100 Class J
125 Class J
125 Class J
150 Class J
150 Class J
150 Class J

10
10
10
65
65
65

50
50
50
100
100
100

10
10
10
30
30
30

125
125
125
250
250
250

10
10
10
30
30
30

50
50
50
250
250
250

DILM72(…)
DILM80(…)

10
10

250
600

250
600

100
100

150 Class J
300 Class J

65
65

100
250

30
30

250
300

30
30

250
350

DILM95(…)
DILM115(…)
DILM150(…)
DILM170(…)

10
10
10
10

600
600
600
600

600
600
600
600

100
100
100
100

300 Class J
300 Class J
300 Class J
300 Class J

65
65
65
65

250
250
250
250

30
30
30
30

300
300
300
300

30
30
30
30

350
350
350
350

DILM185(…)
DILM225(…)
DILM250(…)
DILM300(…)

18
18
18
30

700
700
700
800

600
600
600
600

-

CB only
CB only
CB only
CB only

65
65
65
42

250
250
250
600

30

800

30

600

DILM400(…)
DILM500(…)
DILM570(…)

30
30
30

800
800
800

600
600
600

-

CB only
CB only
CB only

42
42
42

600
600
600

30
30
30

800
800
800

30
30
30

600
600
600

DILM580(…)
DILM650(…)
DILM750(…)
DILM820(…)
DILM1000(…)
DILM1600(…)

30
30
42
42
85
85

2000
2000
2000
2000
2000
2000

1200
1200
1200
1200
1200
-

85
85
85
85
85
85

2000
2000
2000
2000
2000
2000

85
85
85
85
85
-

1200
1200
1200
1200
1200
-

85
85
85
85
85
85

2000
2000
2000
2000
2000
2000

85
85
85
85
85
85

1200
1200
1200
1200
1200
-

82

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Contactors for resistive load

1 DILM, DILEM
Rating data
Single-phase rating AC-1

1

2

3

4

5

6

7

Three-phase rating AC-1

)

1

1

3

5

2

4

6

8

Voltage in V
220
380
230
400
240
440

660
690

Max.
upstream
fuse
gG/gL

kW

kW

kW

Three-phase rating AC-1

Voltage in V
220
380
230
400
240
440

660
690

Max.
upstream
fuse
gG/gL

A

Rated
operational
current
I e = Ith
or Ithe
A

kW

kW

kW

1

3

5

7

1

3

5

7

1

3

5

7 1)

2

4

6

8

2

4

6

8

2

4

6

8

Voltage in V
220
380
230
400
240
440

660
690

Max.
upstream
fuse
gG/gL

A

Rated
operational
current
I e = Ith
or Ithe
A

kW

kW

kW

A

Rated
operational
current
I e = Ith
or Ithe
A

Open version
10
10

18
18

31
31

50
50

50
50

7
7

13
13

20
20

20
20

20
20

18
18

31
31

54
54

50
50

50
50

12

21

37

63

60

–

–

–

–

–

21

37

65

63

60

10

18

31

–

50

7

13

22

–

20

18

31

54

–

50

13
18

22
32

38
55

–
–

60
88

–
13

–
22

–
38

–
–

–
35

22
32

38
55

65
95

–
–

60
88

21

36

63

–

100

14

25

43

–

40

36

63

109

–

100

26

45

78

–

125

18

31

54

–

50

45

78

136

–

125

34

59

102

–

163

24

41

71

–

65

59

102

176

–

163

42

72

125

–

200

29

50

87

–

80

72

125

217

–

200

47

81

141

–

225

33

56

98

–

90

81

141

244

–

225

57

99

172

–

275

40

69

119

–

110

100

172

299

–

275

68

117

204

–

325

47

81

141

–

130

118

203

353

–

325

84

144

251

–

400

58

100

174

–

160

145

250

434

–

400

101

175

317

–

460

70

120

220

–

185

175

302

549

–

460

144

248

431

800

688

100

172

299

315

275

262

453

786

–

688

165

284

494

800

788

114

197

342

315

315

300

519

900

–

788

172

297

516

1000

825

120

206

357

400

330

333

576

1000

–

875

183

316

548

1000

875

126

219

380

400

350

381

658

1143

–

1000

261

451

784

1250

1250

181

313

543

500

500

476

825

1429

–

1250

366

632

1097

–

1750

253

438

760

800

700

667

1152

2000

–

1750

418

722

1254

–

2000

290

500

869

800

800

762

1316

2286

–

2000

444

767

1332

–

2125

308

531

923

1000

850

810

1400

2429

–

2125

470

812

1411

–

2250

326

563

977

1000

900

857

1480

2572

–

2250

523

903

1568

–

2500

362

625

1086

1000

1000

953

1646

2858

–

2500

732

1264

2195

–

3500

507

875

1520

–

1400

1334

2300

4000

–

3500

1045

1805

3135

–

5000

724

1251

2172

–

2000

1905

3290

5716

–

5000

1150

1985

3449

–

5500

796

1376

2389

–

2200

2095

3619

6288

–

5500

1358

2346

4075

–

6500

941

1626

2827

–

2600

2476

4277

7430

–

6500

Notes

84

1)

Contact 7 – 8 only with DILEM4(-G), DILMP20...

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Contactors
Contactors for resistive load

1.1

DILM, DILEM
Part no.

1
Ordering
data

Required
accessories:

Notes

Paralleling
links

AC
operated

Page

Part no.

DILEM-10(…)

4

P1DILEM

DILEM-01(…)

4

P1DILEM

DILEM4(…)

4

P1DILEM

DILM7-…(…)

18

DILM12-XP1

DILMP20(…)
DILM17-…(…)

34
18

DILM12-XP1
DILM32-XP1

DILM25-…(…)

18

DILM32-XP1

DILM40(…)

20

DILM65-XP1

DILM50(…)

20

DILM65-XP1

DILM65(…)

20

DILM65-XP1

DILM80(…)

20

DILM150-XP1

DILM95(…)

20

DILM150-XP1

DILM115(…)

20

DILM150-XP1

DILM150(…)

20

DILM150-XP1

DILM170(…)

20

DILM150-KP1

DILM185A(…)

30

DILM185-XP1

DILM225A(…)

30

DILM185-XP1

DILM250(…)

30

–

DILM300A(…)

30

–

DILM400(…)

30

–

DILM500(…)

30

–

DILM580(…)

30

–

DILM650(…)

30

–

DILM750(…)

30

–

DILM820(…)

30

–

DILH1400(…)

32

–

DILH2000(…)

32

–

DILH2200(…)

32

–

DILH2600(…)

32

–

Accessories
Auxiliary contact modules
Set of paralleling links
Enclosure
Accessories

Page
6
36
53
63
52

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

85

1.1

Mini contactor relays, contactor relays
Electrical lifespan

DILA DC 1)

1 DILA (AC-15)
Component lifespan (operations)
Ie = Rated operational current

Component lifespan (operations)
Ie = Rated operational current

x 106

X 10 6

20

20

10

10

5

5

2

2

1

1

0.5

0.5

DC
AC-15
0.2

0.2

240 V

0.1
0.01 0.02

0.05 0.1

0.2

0.5

1

2

5

10 A

24 V
L

50 ms
R
0.1
0.01 0.02
0.05

0.1

0.2

Ie
contacts in series

DILER (AC-15)
Component lifespan (operations)
Ie = Rated operational current
x 106

20
10
5

2
1
0.5
AC-15
240 V

0.1
0.01 0.02

0.05 0.1

0.2

0.5

1

2

5

10 A

Ie

86

1

2

5

10 A

Ie
1) Three

0.2

0.5

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Contactors
Switching conditions

1.1

kW
90
75
55
45
37
30
22
18.5
15
11
7.5
5.5
4
3

Rated operational current I e 50 – 60 Hz

Rated output of three-phase motors 50 – 60 Hz

Normal switching duty

1
AC-3/400V

A
170
150
115
95
80
65
50
40
32
25

DILM170
DILM150
DILM115
DILM80

DILM95

DILM72

DILM65
DILM50

DILM40

DILM38

DILM32
DILM25

18

DILM17

DILM15

DILM12

12
9
7

DILM9, DILEM
DILM7

5
4

DILEM12
DILEM-G

3

DILEM
2

0.01

0.02

0.04 0.06 0.1

0.4 0.6

0.2

1

2

4

6

10

Normal AC induction motor
Operating characteristics
Make:
from stop
Break:
during run
Electrical characteristics:
Make:
up to 6 X rated motor current
Break:
up to 1 X rated motor current
Utilization category
100 % AC-3
Typical applications:
Lifts
Compressors
Mixers
Escalators
Agitators
Pumps
Fan
Centrifuges
Conveyor belts
Air conditioning sysBucket-elevator
Hinged flaps
General drives for manufacturing and processing machines

Component lifespan [millions of operations]

560
450
400
355
315
250
200
160
132
110
90

A
1600 DILM1600
Rated operational current I e 50 – 60 Hz

Rated output of three-phase motors 50 – 60 Hz

kW
900

AC-3/400 V

DILM1000

1000
820
750
650
580

DILM820
DILM750
DILM650
DILM580/570

500
400
300

DILM500
DILM400
DILM300A

250
225
185

DILM250
DILM225A
DILM185A

75

145

55

104

45

85

37

72

30

58

22
18.5

43
36

15

30

11
7.5

23
16
0.01

DILM570

0.04 0.06 0.1

0.02

0.2

0.4 0.6

1

2

3 4 5 6 8 10

Component lifespan [millions of operations]

Extreme switching duty

19
17
15
9
7.5
5.5
4
3.5
2.5

Rated operational current Ie 50 – 60 Hz

Rated output of three-phase motors 50 – 60 Hz

52
47
41
33

Normal AC induction motor
Operating characteristics
Inching, plugging, reversing
Electrical characteristics:
Make:
up to 6 X rated motor current
Break:
up to6 X rated motor current
Utilization category
100 % AC-4
Typical applications:
Printing machines
Wire-drawing
Centrifuges
Special drives on manufacturing and processing machines

AC-4/400V

A

kW

100 DILM150, DILM170
DILM115
90
80 DILM95
DILM80
66
40 DILM65, DILM72
DILM50
35
32 DILM40
20 DILM32, DILM38
DILM25
17
13
9 DILM12.15
DILM9
8.3
6.5 DILM7
5
4
3
DILEM12, DILEM

2

0.01

0.02

0.04 0.06

0.1

0.2

0.4 0.6

1

2

4

6

10

Component lifespan [millions of operations]

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

87

1.1

Contactors
Switching conditions

1 Extreme switching duty

Rated operational current I e 50 – 60 Hz

Rated output of three-phase motors 50 – 60 Hz

kW
750
450
355
315
280
250
200
160
132
110
90
75
55
45
37
30
22
18.5
15

800
656
576
512
456
360
296
240
200
164
140

Normal AC induction motor
Operating characteristics
Inching, plugging, reversing
Electrical characteristics:
Make:up to 6 X rated motor current
Break:
6 X rated motor current
Utilization category
100% AC-4
Typical applications:
Centrifuges
Printing
Wiremachines drawing
machines
Special drives on manufacturing and processing machines

DILM1000
DILM820
DILM750
DILM650
DILM580
DILM500/570
DILM400
DILM300A
DILM250
DILM225A
DILM185A

104
85
72
58
43
36
30

11

23

7.5

16

5.5

12

4

8.8
6.5

3

AC-4/400 V

A
1280 DILM1600

2.2

5

1.5

3.5

0.02 0.03 0.04 0.06 0.1

0.01

0.2 0.3 0.4 0.6

1

2

3 4 5 6 8 10

Component lifespan [millions of operations]

Breaking current A

Switching conditions for 3 pole, non-motor loads
2600
2200
2000
1800
1400

DILH2600
DILH2200
DILH2000
DILM1600

AC-1/400 V

DILM1400

1000
900 850
800 700
500
400
350
300
275
160
130
110
90
80
65

DILM820/1000
DILM650 DILM750
DILM500

Operating characteristics
Non inductive and slightly inductive loads
Electrical characteristics:
Make: 1 X rated operational current
Break:1 X rated operational current
Utilization category
100% AC-1
Typical applications:
Electric heat

DILM580/570
DILM750

DILM400
DILM300
DILM250
DILM225
DILM185
DILM150, M170
DILM115
DILM95
DILM65
DILM50

50
40
35

DILM40

20

DILEM

DILM80

DILM72

DILM25, M32; M38
DILM17

DILM

7, M
9, M
12 ,

10

M15

7
5
4
3
2
1
0.1

0.2

0 .3

0 .5

0.7

1

2

3

5

7

10

Component lifespan [Millions of operations]

88

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Contactors
Switching conditions

1.1

Switching conditions for 4 pole, non-motor loads

1

Breaking current A

AC-1/400 V

200

DILMP200

160

DILMP160

125

DILMP125

80

DILMP80

63

DILMP63

45

DILMP45

32

DILMP32
DILMP20

22

0.1

Operating characteristics
Non inductive and slightly inductive loads
Electrical characteristics:
Make: 1 X rated operational current
Break: 1 X rated operational current
Utilization category
100% AC-1
Typical applications:
Electric heat

0.2

0.4

0.6

1

2

4

6

10

Component lifespan [Millions of operations]

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

89

1.1

Contactors
Short-time loading

1 Short-time loading 3 pole
Time interval between two loads: 15 minutes

AC-1/400 V

Short-time current

A
700
600 DILM65, M72
500 DILM50
450 DILM40
400
350 DILM32, M38
300 DILM25
250
200

DILM17

150
120
100
90
70

DILM12, M15
DILM7, M9
DIL(E)M(-12)
DILE(E)M(-12)

50
40
30

20
15

5

3

2

7

20

10

30

50 70 100

Duration of load

Short-time
current

A
19000

10000
8000
6000

200 300
3 min 5 min

500 700 900 Seconds
10 min 15 min

AC-1/400 V

DILM1600

DILM820
DILM750
DILM650
DILM580
DILM570
DILM500

DILM1000, DILH1400

DILH

5000
4000

1 min

2000

/220

0/26

00

DILM400
DILM300A

3000
2500

DILM250

2000
1800
1500

DILM185A/225A

1100
1000

DILM80/95

DILM115,150,170

700
500
400
300

200

2

3

5

7

10

20

Duration of load

90

30

50 70 100
1 min

200 300

500 700 900 Seconds

3 min 5 min 10 min 15 min

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Operating frequency

Determination of the maximum operating frequency dependent on the rating and utilization category
(recommended values) for 400 V
P N = max. rated motor output (kW) of respective contactor according to

Page 18 and

1

Page 4

S/h = max. operation per hour

Ops./h

DILEM, DILM, DILH

6000

Part no.

Characteristic
AC-1

AC-3

AC-2
AC-4

7
3
3
3
3

6
1
2
2
4

8
5
5
5
5

4000

DILE(E)M(-12)
DILM7, 9, 12, 15
DILM17, 25, 32, 38
DILM40, 50, 65, 72
DILM80, 95, 115, 150, 170

2000

1000
800
600

400

200

100
0

10

20

30

40

50

60

70

80

90

100 %
N [kW]

Determination of the maximum operating frequency dependent on the rating and utilization category
(recommended values)
P N = max. rated motor output (kW) of respective contactor according to

Page 28 and

Page 32

S/h = max. operation per hour
Ops./h

DILEM, DILM, DILH
4000

Part no.

3000

DILM185A
DILM225A
DILM250
DILM300A
DILM400
DILM500
DILM580
DILM650
DILM750
DILM820
DILM1000
DILM1600
DILH1400
DILH2000
DILH2200
DILH2600

2000
1500

1000
800
600
500
400
300

200
150
100

Characteristic
AC-1
2
2
2
3
3
3
3
3
3
3
3
10
10
10
10
10

AC-3
1
1
1
2
2
2
4
4
4
4
4
10
–
–
–
–

AC-4
8
8
8
9
9
9
7
7
7
7
7
7
–
–
–
–

50
0

10

20

30

40

50

60

70

80

90

100 %
PN [kW]

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

91

1.1

Contactors
Switching of DC current

1 DC current switching
– – – – – when necessary
conductor to be
supplied by customer

DILEEM ... DILM700

Without overload relay
” 60 V DC

1 pole

2 pole

DILEM4
DILMP...

1 pole

2 pole

Wiring, star-delta combination with DILM32-XTEY20
L0 1

L0 1
95

-F1
96

0

14

-Q11

I

13

57

-K1
58

67

-K1

22

-Q15

22

-Q13

21

A1

-K1
A2

L0 2

92

21

A1

-Q11

-Q13

A1

-Q15
A2

N

68

A2

L02

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

> 60 V DC

With overload relay
> 60 V DC

1.1

Mini contactor relays, contactor relays

Technical data

1

DILER, DILA
DILA

DILA…XHI

DILER

DILE…

General
Standards

IEC/EN 60947, VDE 0660, UL, CSA

Lifespan, mechanical
AC operated

Operations

x 10 6

20

10

10

10

DC operated

Operations

x 10 6

20

10

20

20

9000

9000

9000

9000

Maximum operating frequency
Maximum operating frequency

Operations/h

Climatic proofing

Damp heat, constant, to IEC 60068-2-78;
Damp heat, cyclic, to IEC 60068-2-30

Ambient temperature
Open

°C

-25…60

-25…60

-25…50

-25…50

Enclosed

°C

-25…40

-25…40

-25…40

-25…40

Ambient temperature for storage

°C

-40 - 80

-40 - 80

Mounting position

Any, except vertically with terminals
A1/A2 below

180°

°

90

°

90

90

°

30°

–

Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 ms
Basic devices with auxiliary contact module
N/O

g

7

7

10

NC

g

5

5

8

8

IP20
IP20
Finger- and back-of-hand proof

IP20

IP20

Protection type
Protection against direct contact when actuated
from front (EN 50274)

10

Weight
AC operated

kg

0.23

0.05

0.17

–

DC operated

kg

0.28

0.05

0.2

–

Solid

mm 2

1 x (0.75 - 4)
2 x (0.75 - 2.5)

1 x (0.75 - 4)
2 x (0.75 - 2.5)

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)

Flexible with ferrule

mm 2

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)

1 x (0.75 - 1.5)
2 x (0.75 - 1.5)

1 x (0.75 - 1.5)
2 x (0.75 - 1.5)

Solid or stranded

AWG

18 - 14

18 - 14

18 - 14

18 - 14

M3.5

M3.5

M3.5

M3.5

Terminal capacity
Screw terminals

Terminal screw
Pozidriv screwdriver

Size

2

2

2

2

Flat-blade screwdriver

mm

Max. tightening torque

Nm

0.8 x 5.5
1x6
1.2

0.8 x 5.5
1x6
1.2

0.8 x 5.5
1x6
1.2

0.8 x 5.5
1x6
1.2

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
1 x (0.75 - 1.5)
2 x (0.75 - 1.5)
1 x (0.75 - 1.5)
2 x (0.75 - 1.5)
18 - 14

1 x (1 - 2.5)
2 x (1 - 2.5)
1 x (1 - 2.5)
2 x (1 - 2.5)
–

1 x (1 - 2.5)
2 x (1 - 2.5)
1 x (1 - 2.5)
2 x (1 - 2.5)
–

0.6 x 3.5

1 x (16 - 14)
2 x (16 - 14)
0.6 x 3.5

1 x (16 - 14)
2 x (16 - 14)
0.6 x 3.5

Spring-loaded terminals
Solid

mm²

Flexible with ferrule

mm²

Flexible without ferrule DIN 46228

mm²

Solid or stranded

AWG

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
1 x (0.75 - 1.5)
2 x (0.75 - 1.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
18 - 14

mm

0.6 x 3.5

Flat-blade screwdriver

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

93

1.1

Mini contactor relays, contactor relays

1 DILER, DILA
Contacts
Interlocked opposing contacts to EN 60947-4-1,
Annex L, including auxiliary contact module
Rated impulse withstand voltage

U imp

DILA

DILA…XHI

DILER

DILE…

Yes

Yes

Yes

Yes

V AC

6000

6000

6000

6000

Ui

V AC

III/3
690

III/3
690

III/3
690

III/3
690

Ue

V AC

690

500

600

600

Between coil and auxiliary contacts

V AC

400

400

300

300

Between the auxiliary contacts

V AC

400

400

300

300

Overvoltage category/degree of pollution
Rated insulation voltage
Rated operating voltage
Safe isolation according to EN 61140

Rated operational current
AC-15
220/240 V

Ie

A

4

4

6

4

380/415 V

Ie

A

4

4

3

2

500 V

Ie

A

1.5

1.5

1.5

1.5

DC 1)
L/R 15 ms
Contacts in series:
1

24 V

A

10

10

2.5

2.5

1
2

60 V
60 V

A
A

6
10

6
10

–
2.5

–
2.5

1

110 V

A

3

3

–

–

3

110 V

A

6

6

1.5

1.5

1

220 V

A

1

1

–

–

3

220 V

A

5

5

0.5

0.5

3

24 V

A

4

2.5

–

–

3

60 V

A

4

1

–

–

3

110 V

A

2

0.5

–

–

3

220 V

A

1

0.25

–

–

3

24 V

A

2.5

2.5

–

–

3

60 V

A

1

1

–

–

3

110 V

A

0.5

0.5

–

–

3

220 V

A

0.25

0.25

–

–

L/R 50 ms
Contacts in series:

DC-13 (6xP)
Contacts in series:

Control circuit reliability
(at U e = 24 V DC, Umin = 17 V, Imin = 5.4 mA)

Fault
probability

Conventional thermal current

I th

<10 -8 , < one failure in 100 million operations
A

16

16

10

10

220/240 V

PKZM0

4

–

4

4

380/415 V

PKZM0

4

–

4

4

A gG/gL 10

10

6

6

A fast

–

–

10

10

AC operated

W

0.3

0.3

0.2

0.2

DC operated

W

0.3

0.3

0.3

0.3

Short-circuit strength without welding
Maximum overcurrent protection device

Short-circuit protection rating maximum fuse 2)
500 V
500 V
Current heat loss at load of I th

Notes

94

1)

Switch-on and switch-off conditions based on DC-13, time
constant as specified
2) See characteristic curve "Fuses" for time/current characteristics (please enquire)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Mini contactor relays, contactor relays

DILER, DILA

1
DILA

DILA…XHI

DILER

DILE…

Magnet systems
Voltage tolerance
AC operated
Single-voltage coil 50 Hz and dualvoltage coil 50 Hz, 60 Hz
Dual-frequency coil 50/60 Hz

Pick-up

x Uc

0.8…1.1

–

0.8…1.1

–

Pick-up

x Uc

0.8…1.1

–

0.85…1.1

–

Pick-up
Pick-up

x Uc
x Uc

0.8…1.1

–

0.85…1.3

–

0.7 - 1.3

–

0.7 - 1.3

–

DC operated 1)
Starting voltage
At 24 V: without auxiliary contact
module (40 °C)
Power consumption
50 Hz

Pick-up

VA

24

–

25

–

50 Hz

Sealing

VA

3.4

–

4.6

–

50 Hz

Sealing

W

1.2

–

1.3

–

60 Hz

Pick-up

VA

30

–

25

–

60 Hz

Sealing

VA

4.4

–

4.6

–

60 Hz

Sealing

W

1.4

–

1.3

–

50/60 Hz

Pick-up

VA

–

Sealing

VA

50/60 Hz

Sealing

W

DC operated

Pick-up =
sealing

W

–

30
29
5.4
3.9
1.6
1.1
2.6

–

50/60 Hz

27
25
4.2
3.3
1.4
1.2
3

–

% DF

100

–

100

–

AC operated closing delay

ms

15 - 21

–

14 - 21

–

AC operated normally open contact opening
delay
AC operated with auxiliary contact module,
max. closing delay
DC operated closing delay

ms

9 - 18

–

8 - 18

–

ms

–

–

45

45

Duty factor
Changeover times at 100 % U c (recommended values)

–
–

–
–

ms

31

–

26 - 35

–

DC operated normally open contact opening
delay

ms

12

–

15 - 25

–

DC operated with auxiliary contact module,
max. closing delay

ms

–

–

70

70

Notes

1)

Smoothed DC, three-phase bridge rectifier or smoothed two-phase bridge rectifier

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

95

1.1

Contactors
Amplifier modules, electronic timer module, contactor monitoring device

1 ETS-VS3, DILM, CMD

General
Standards

ETS4-VS3

DILM32-XTE

CMD(24VDC)
CMD(220-240VAC)

IEC/EN 60947, VDE
0660, UL, CSA

DIN EN 61812, IEC/EN
60947, VDE 0660,
UL, CSA

IEC/EN 60947
UL
CSA

Lifespan, mechanical
AC operated

c (contacts)

x 10 6

–

3

10

DC operated

c (contacts)

x 10 6

30

3

3

c (contacts)

x 10 6

72000

–

9000

Maximum operating frequency
DC operated
Climatic proofing

Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Ambient temperature
Storage
Open

°C
°C

–
-25 - 60

-40 - 80
-25 - 60

-40 - 80
-25 - 50

Enclosed
Mounting position

°C

-25 - 45
Any

-25 - 40
As required, except
suspended

–
Any

g

10

–

–

N/O

g

–

6

4

NC

g

–

6

4

Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 20 ms
N/O
Half-sinusoidal shock 10 ms

Protection type

IP20
IP20
Finger- and back-of-hand proof

IP20

kg

0.09

0.08

0.1

Solid

mm²

Flexible with ferrule

mm²

1 x (0.75 - 2.5)
2 x (0.75 - 2.5) 1)
1 x (0.75 - 2.5)
2 x (0.75 - 1.5) 1)

1 x (0.75 - 2.5)
2 x (0.75 - 1.5)
1 x (0.75 - 1.5)
2 x (0.75 - 1.5)

1 x (0.75…2.5)
2 x (0.75…1.5)
1 x (0.75…1.5)
2 x (0.75…1.5)

Solid or stranded

AWG

Protection against direct contact when actuated from front (EN 50274)
Weight
Terminal capacity

Terminal screw

16 - 14

18 - 14

18…14

M3.5

M3.5

M3.5

Pozidriv screwdriver

Size

2

2

2

Flat-blade screwdriver

mm

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

Max. tightening torque

Nm

1.2

1.2

1.2

1)

Notes

96

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Use equal cross-sections only

Contactors
Amplifier modules, electronic timer module, contactor monitoring device

1.1

ETS-VS3, DILM, CMD

1
ETS4-VS3

DILM32-XTE

CMD(24VDC)

CMD(220-240VAC)

Contacts
Rated impulse withstand voltage

U imp

V AC

Overvoltage category/degree of pollution

6000

6000

8000

4000

III/2

III/3

III/3

III/3

Rated insulation voltage

Ui

V AC

440

600

100

250

Rated operating voltage

Ue

V

440 AC

400 AC

24 DC

250 AC

220/240 V

Ie

A

2

3

–

–

280/415 V

Ie

A

2

–

–

–

–

Rated operational current
AC-15

DC-13 1)
DC-13 L/R

15 ms
Contacts in series:

DC-13 L/R

1

24 V

A

2.6

1

–

1

60 V

A

1

0.2

–

–

1

110 V

A

0.6

0.2

–

–

1

220 V

A

0.2

0.1

–

–

50 ms
Contacts in series:

DC-13 L/R

1

24 V

A

2

1

–

–

1

60 V

A

0.6

0.2

–

–

1

110 V

A

0.08

0.2

–

–

1

220 V

A

0.08

0.1

–

–

300 ms
Contacts in series:
1

24 V

A

0.6

1

–

–

1

60 V

A

0.2

0.2

–

–

1

110 V

A

0.08

0.2

–

–

1

220 V

A

0.03

0.1

–

–

V AC

–

250

–

–

V AC

–
<10 -8 , < one failure in
100 million operations

250
–

–
–

–
–

Safe isolation according to EN 61140
Between coil and auxiliary contacts
Between the auxiliary contacts
Control circuit reliability
(at Ue = 24 V DC, U min = 17 V, I min = 5.4 mA)

Fault
probability

Conventional thermal current

I th

A

6

4

–

–

Switch
operations
Switch
operations

x 10 6

7

–

–

–

x 10 6

1

–

–

–

Component lifespan
AC-15
230 V, I e = 0.1 A
230 V, I e = 1.2 A
Short-circuit rating without welding
Short-circuit protection rating maximum fuse 2)

Notes

500 V

A gG/gL

–

4

2

2

500 V

A fast

4

–

–

–

1)
2)

Switch-on and switch-off conditions based on DC-13, time constant as specified
See transparent overlay "Fuses" for time/current characteristics (please enquire)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

97

1.1

Contactors
Amplifier modules, electronic timer module, contactor monitoring device

1 ETS-VS3, DILM, CMD
ETS4-VS3

DILM32-XTE

CMD(24VDC)
CMD(220-240VAC)

Magnet systems
Voltage tolerance
Starting voltage
AC operated
Pick-up

x Uc

–

0.85 - 1.1

0.85 - 1.1

Pick-up

x Uc

0.85 - 1.2

0.7 - 1.2

0.85 - 1.1

AC operated

Sealing

VA

–

2

4

AC operated

Sealing

W

–

1.8

4

DC operated

Pick-up =
sealing

W

0.6

–

4

Duty factor

% DF

100

100

100

Changeover times at 100 % Uc (recommended values)
DC operated closing delay
DC operated opening delay

ms
ms

7
3

–
–

–
–

Max. operating frequency

Ops/h

–

3600

–

6 A/250 V

Ops/h

–

360

–

On-delayed

ms

–

< 50

–

Off-delayed

ms

–

< 200

–

%

–

<5

–

ms

–

70

–
–

DC operated 1)
Power consumption

Maximum operating frequency

Minimum on duration

Repetition accuracy (with constant parameters)

Deviation

Recovery time (after 100% time delay)
Contact changeover time
DILM32-XTEE11/DILM32-XTED11

tu

ms

–

10

DILM32-XTEY20

tu

ms

–

50

–

CMD

tu

ms

–

–

100 ± 20%

1)

Notes

98

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Smoothed DC, three-phase bridge rectifier or smoothed two-phase
bridge rectifier

1.1

Mini contactor relays

DILEEM, DILEM

1
DILEEM
DILEM
DILEM12

DILEEM-G
DILEM-G
DILEM12-G

DILEM4

DILEM4-G

General
Standards

IEC/EN 60947, VDE 0660, CSA, UL

Lifespan, mechanical; Coil 50/60 Hz

at 50 Hz

Lifespan, mechanical

c (contacts)

7

–

7

–

x 10 6

10

20

20

–

Ops/h

9000

Maximum operating frequency
Mechanical
Electrical (Contactor without overload relay)

Characteristic curves Page 91

Climatic proofing

Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Ambient temperature
Open

°C

-25 - 50

Enclosed

°C

-25 - 40

Mounting position

Any, except for vertically with terminals A1/A2 below
A1

A2

Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 ms
Basic device without auxiliary contact module
Main circuit normally open
contact
Auxiliary contacts
NC/Normally open contact
Basic devices with auxiliary contact module
Main circuit normally open
contact
Auxiliary contacts Normally
open contact/NC

g

10

g

10/8

g

10

g

20/20

Protection type
Protection against direct contact when actuated from front (EN 50274)
Weight
Terminal capacity: main and auxiliary contacts

10/8

–

–

0.2

0.17

IP20
Finger- and back-of-hand proof
kg

0.2

Solid

mm²

Flexible with ferrule

mm²

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
1 x (0.75 - 1.5)
2 x (0.75 - 1.5)

Solid or stranded

AWG

Terminal screw

0.17

18 - 14
M3.5

Pozidriv screwdriver

Size

2

Flat-blade screwdriver

mm

Max. tightening torque

Nm

0.8 x 5.5
1x6
1.2

Terminal capacity springloaded terminals main and control circuits
Solid

mm²

Flexible with ferrule

mm²

Flat-blade screwdriver

mm

1 x (1 - 2.5)
2 x (1 - 2.5)
1 x (1 - 2.5)
2 x (1 - 2.5)
0.6 x 3.5

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

99

1.1

Mini contactor relays

DILEEM, DILEM
1
DILEEM
DILEEM-G

DILEM
DILEM-G

DILEM4

DILEM4-G

DILEM12
DILEM12-G

V AC

6000

6000

6000

6000

6000

V AC
V AC

III/3
690
690

III/3
690
690

III/3
690
690

III/3
690
690

III/3
690
690

Safe isolation according to EN 61140
Between coil and contacts
Between the contacts

V AC
V AC

300
300

300
300

300
300

300
300

300
300

Making capacity of up to 440 V (cos as specified in IEC/EN 60947)
Breaking
220/230 V
capacity
380/400 V

A
A
A

110
90
90

110
90
90

110
90
90

110
90
90

120
96
96

A
A

64
42

64
42

64
42

72
42

Main contacts
Rated impulse withstand voltage

U imp

Overvoltage category/pollution degree
Rated insulation voltage
Rated operating voltage

Devices lifespan

Ui
Ue

500 V
660/690 V
AC-1
AC-3

64
42
Engineering Page 88
Engineering Page 87

AC-4
Short-circuit protection rating maximum fuse
Type “2” coordination 500 V
Type “1” coordination 500 V

Engineering Page 87
gL/gG
gL/gG

A
A

10
20

10
20

10
20

10
20

20
35

I th
I th
I th
I th

A
A
A

22
20
19

22
20
19

22
20
19

22
20
19

22
20
19

A

16

16

16

16

16

I th
I th

A
A

50
40

50
40

60
50

60
50

50
40

220/230 V

Ie

A

6.6

9

9

9

12

240 V
380/400 V
415 V
440 V

Ie
Ie
Ie
Ie

A
A
A
A

6.6
6.6
6.6
6.6

9
9
9
9

9
9
9
9

9
9
9
9

12
12
12
10.5

500 V
660/690 V
220/230 V
240 V
380/400 V

Ie
Ie
P
P
P

A
A
kW
kW
kW

5
3.5
1.5
1.8
3

6.4
4.8
2.2
2.5
4

6.4
4.8
2.2
2.5
4

6.4
4.8
2.2
2.5
4

9
5.2
3.5
3
5.5

415 V

P

kW

3.1

4.3

4.3

4.3

5.5

440 V
500 V
660/690 V

P
P
P

kW
kW
kW

3.3
3
3

4.6
4
4

4.6
4
4

4.6
4
4

5.5
5.5
4

220/230 V

Ie

A

5

6.6

6.6

6.6

6.6

240 V
280/400 V
415 V
440 V
500 V
660/690 V

Ie
Ie
Ie
Ie
Ie
Ie

A
A
A
A
A
A

5
5
5
5
3.7
2.9

6.6
6.6
6.6
6.6
5
3.4

6.6
6.6
6.6
6.6
5
3.4

6.6
6.6
6.6
6.6
5
3.4

6.6
6.6
6.6
6.6
5
3.4

220/230 V
240 V
380/400 V
415 V
440 V
500 V

P
P
P
P
P
P

kW
kW
kW
kW
kW
kW

1.1
1.3
2.2
2.3
2.4
2.2

1.5
1.8
3
3.1
3.3
3

1.5
1.8
3
3.1
3.3
3

1.5
1.8
3
3.1
3.3
3

1.5
1.8
3
3.1
3.3
2.2

660/690 V

P

kW

2.2

3

3

3

2.2

AC voltage
AC-1 operation
Conventional thermal current 3 pole 50 - 60 Hz
Open

Enclosed 1)
Conventional thermal current, 1-pole
Open 1)
Enclosed 1)
AC-3 operation
Rated operational
current AC-3
open,
50 - 60 Hz,
3-pole1)

Motor rating

AC-4 operation
Rated operational
current AC-4
open,
50 - 60 Hz,
3-pole1)

Rated operational
power

Notes
100

at 40 °C
at 50 °C
at 55 °C

1)

At maximum permissible ambient air temperature

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Mini contactor relays

1.1

DILEEM, DILEM
1
DILEEM
DC voltage
Operations
Rated operational current open
DC-1

DC-3

DC-5

DILEM12

DILEM12
-G

20
20
20

20
20
20

20
20
20

20
20
20

20
20
20

20
20
20

20
20
20

20
20
20

110 V

Ie

A

20

20

20

20

20

20

20

20

220 V
12 V
24 V
60 V
110 V

Ie
Ie
Ie
Ie
Ie

A
A
A
A
A

20
6
6
3
2

20
6
6
3
2

20
8
8
4
3

20
8
8
4
3

20
8
8
4
3

20
8
8
4
3

20
8
6
4
3

20
8
8
4
3

220 V
12 V
24 V

Ie
Ie
Ie

A
A
A

–
1.8
1.8

–
1.8
1.8

–
2.5
2.5

–
2.5
2.5

1
2.5
2.5

1
2.5
2.5

–
2.5
2.5

–
2.5
2.5

60 V

Ie

A

1.8

1.8

2.5

2.5

2.5

2.5

2.5

2.5

Ie
Ie

A
A

1.8
0.2

1.8
0.2

1.5
0.3

1.5
0.3

2.5
1

2.5
1

1.5
0.3

1.5
0.3

W

2

3.5

2

3.5

2.7

4.7

2

3.5

W

0.5

0.7

0.5

0.7

–

–

0.5

0.7

Pick-up

x Uc

0.8 - 1.1

–

0.8 - 1.1

–

0.8 - 1.1

–

0.8 - 1.1

–

Pick-up

x Uc

0.8 - 1.1

–

–

0.85 - 1.1

–

0.8 - 1.1

–

Pick-up

x Uc

–

0.8 - 1.1

0.85 1.1
–

0.8 - 1.1

–

0.85 - 1.1

–

0.8 - 1.1

Pick-up
Pick-up
Sealing

VA
W
VA

25
22
4.6

–
–
–

25
22
4.6

–
–
–

25
22
4.6

–
–
–

25
22
4.6

–
–
–

Sealing
Pick-up
Pick-up

W
VA
W

1.3
30
26

–
–
–

1.3
30
26

–
–
–

1.3
30
26

–
–
–

1.3
30
26

–
–
–

Sealing

VA

Sealing
Pick-up

W
VA

5.4
1.6
29

–
–
–

5.4
1.6
29

–
–
–

5.4
1.6
29

–
–
–

5.4
1.6
29

–
–
–

Pick-up
Sealing
Sealing
Pick-up

W
VA
W
VA

24
3.9
1.1
25

–
–
–
–

24
3.9
1.1
25

–
–
–
–

24
3.9
1.1
25

–
–
–
–

24
3.9
1.1
25

–
–
–
–

Pick-up

VA

30

–

30

–

30

–

30

–

Pick-up

VA
VA/W

29
–

–
2.6

29
–

–
2.6

29
–

–
2.6

29
–

–
2.6

% DF

100

100

100

100

100

100

100

100

ms
ms

14
21

26
35

14
21

26
35

14
21

26
35

14
21

26
35

ms
ms
ms

8
18
Max. 45

15
25
Max. 70

8
18
Max. 45

15
25
Max. 70

8
18
Max. 45

15
25
Max. 70

8
18
Max. 45

15
25
Max. 70

Single-voltage coil, 50 Hz, and dualvoltage coil, 50 Hz, 60 Hz

Dual-frequency coil 50/60 Hz
at 60 Hz

Single-voltage coil, 50 Hz, and dualvoltage coil, 50 Hz, 60 Hz
Dual-frequency coil 50/60 Hz at 50 Hz
Dual-frequency coil 50/60 Hz at 60 Hz
Power consumption
pick-up = sealing

Duty fac tor
Switching times at 100 % Uc
N/O
Closing delay min.
Closing delay max.
Opening delay min.
Opening delay max.
Closing delay with top mounting
auxiliary contact
Changeover time at 110 % U c tactors
Changeover time min.

Notes

DILEM4G

A
A
A

Dual-frequency coil 50/60 Hz at 50 Hz

Coil

DILEM4

Ie
Ie
Ie

DC operated
Power consumption

Reversing con-

DILEMG

12 V
24 V
60 V

At Ie to AC-3/400 V
Magnet systems
Voltage tolerance
Single-voltage coil 50 Hz and
dual-voltage coil 50 Hz, 60 Hz
Dual-frequency coil 50/60 Hz

DC operation1)

DILEM

Engineering Page 92

110 V
220 V
Current heat loss (3-pole or 4-pole)
At Ith

AC operation

DILEEMG

Changeover time maX.
Arcing time at 690 V AC
Lifespan, mechanical; Coil 50/60 Hz

c (contacts)

ms

16

40

16

40

16

40

16

40

ms
ms
x 10 6

21
Max. 12
7

50
Max. 12
–

21
Max. 12
7

50
Max. 12
–

21
Max. 12
7

50
Max. 12
–

21
Max. 12
7

50
Max. 12
–

1)

Smoothed DC or three-phase bridge rectifier
AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

101

1.1

Mini contactor relays

DILEEM, DILEM
1
Auxiliary contact
Interlocked opposing contacts to EN 60947-5-1 Annex L, including
auxiliary contact module
Rated impulse withstand voltage

U imp

V AC

Overvoltage category/pollution degree

DILE(E)M(-12)...

…DILEM

Yes

Yes

6000

6000

III/3

III/3

Rated insulation voltage

Ui

V AC

690

690

Rated operating voltage

Ue

V AC

600

600

Between coil and auxiliary contacts

V AC

300

300

Between the auxiliary contacts

V AC

300

300

Safe isolation according to EN 61140

Rated operational current
AC-15
220/240 V

Ie

A

6

4

380/415 V

Ie

A

3

2

500 V

Ie

A

1.5

1.5

1

24 V

A

2.5

2.5

2

60 V

A

2.5

2.5

3

100 V

A

1.5

1.5

3

220 V

A

0.5

0.5

Conventional thermal current

I th

A

10

10

Control circuit reliability (at U e = 24 V DC, U min = 17 V, I min = 5.4 mA)

Fault
probability

DC

L/R

15 ms

Contacts in series:

<10 --8 , < one failure in 100 million operations

Component lifespan at U e = 240 V
AC-15

c (contacts)

x 10 6

0.2

0.2

c (contacts)

x 10 6

0.15

0.15

PKZM0-4

PKZM0-4

DC 1)
L/R = 50 ms: 2 contacts in series at I e = 0.5 A
Short-circuit rating without welding
Maximum overcurrent protective device
Short-circuit protection rating maximum fuse
500 V

A gG/gL

6

6

500 V

A fast

10

10

0.2

0.2

Current heat loss at load of I th
Per contact

W

1)

Notes

102

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Switch-on and switch-off conditions based on DC-13, time constant as
specified

1.1

Contactors
Basic devices up to 170 A

DILM7 ... DILM170
DILM7

1
General
Standards
Lifespan, mechanical
AC operated
DC operated
Operating frequency, mechanical

DILM9

DILM12

DILM15

DILM17

DILM25

IEC/EN 60947, VDE 0660, UL, CSA
c (contacts)
c (contacts)

Mechanical, AC operated
DC operated
Maximum operating frequency
Electrical (Contactor without overload relay)

x 10 6
x 10 6

Operations/h
Operations/h

10
10

10
10

10
10

10
10

10
10

10
10

9000
9000

9000
9000

9000
9000

5000
5000

5000
5000

5000
5000

Characteristic curves Page 74

Climatic proofing

Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Ambient temperature
Open
Enclosed
Storage
Mounting position AC- and DC operated

°C
°C

-25…60
-25…40

-25…60
-25…40

-25…60
-25…40

-25…60
-25…40

-25…60
-25…40

-25…60
-25…40

°C

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

90

180°

°
90

90
°

°

30°

Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 ms
Main contacts
N/O
Auxiliary contacts

g

10

10

10

10

10

10

N/O
NC

g
g

7
5

7
5

7
5

7
5

7
5

7
5

N/O
Auxiliary contacts

g

5.7

5.7

5.7

5.7

6.9

6.9

N/O
NC

g
g

3.4
3.4

3.4
3.4

3.4
3.4

3.4
3.4

5.3
3.5

5.3
3.5

IP20
IP20
IP20
Finger- and back-of-hand proof

IP20

IP00

IP00

kg
kg

0.23
0.28

0.23
0.28

0.42
0.48

0.42
0.48

mm²

–

–

1 x (0.75 - 16)
2 x (0.75 - 10)
1 x (0.75 - 16)
2 x (0.75 - 10)
1 x 16
1 x 16

18 - 10
–

18 - 10
–

18 - 6
–

Mechanical shock resistance (IEC/EN 60068-2-27) with table mounting
Half-sinusoidal shock 10 ms
Main contacts

Protection type
Protection against direct contact when actuated from front (EN 50274)
Weight
AC operated
DC operated
Terminal type, screw connection
Terminal capacity of main cable
Solid

0.23
0.28

Flexible with ferrule

mm²

Stranded

mm²

1 x (0.75 - 4)
2 x (0.75 - 2.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) 1)
–
–

AWG
mm

18 - 10
–

Solid

mm²

Flexible with ferrule

mm²

1 x (0.75 - 4)
2 x (0.75 - 2.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)

Solid or stranded

AWG

Solid or stranded
Flat conductor

Number of
layers x width x
thickness

18 - 10
–

0.23
0.28

18 - 6
–

Terminal capacity of control circuit cable

Notes
104

18 - 10
1)

18 - 10

Also without ferrule.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

18 - 10

1x
(0.75 - 2.5)
2x
(0.75 - 2.5)
18 - 10

1 x (0.75 - 4)
2 x (0.75 - 4)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)

18 - 14

18 - 14

1.1

Contactors
Basic devices up to 170 A

DILM32

DILM38

DILM40

DILM50

DILM65

DILM72

DILM80

DILM95

DILM115

DILM150

DILM170

1

IEC/EN 60947, VDE 0660, UL, CSA
10
10

10
10

10
10

10
10

10
10

10
10

10
10

10
10

10
10

10
10

10
10

5000
5000

5000
5000

5000
5000

5000
5000

5000
5000

5000
5000

3600
3600

3600
3600

3600
3600

3600
3600

3000
3000

-25…60
-25…40

-25…60
-25…40

-25…60
-25…40

-25…60
-25…40

-25…60
-25…40

-25…60
-25…40

-25…60
-25…40

-25…60
-25…40

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

Characteristic curves Page 74
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
-25…60
-25…40

-25…60
-25…40

-25…60
-25…40

-40 - 80

-40 - 80

-40 - 80
90

180°

°
90

90
°

°

30°

10

10

10

10

10

10

10

10

10

10

10

7
5

7
5

7
5

7
5

7
5

7
5

7
5

7
5

7
5

7
5

7
5

6.9

6.9

10

10

10

10

10

10

10

10

10

5.3
3.5

5.3
3.5

7
5

7
5

7
5

7
5

7
5

7
5

7
5

7
5

7
5

IP00
IP00
Finger- and back-of-hand proof

IP00

IP00

IP00

IP00

IP00

IP00

IP00

IP00

IP00

0.42
0.48

0.9
1.1

0.9
1.1

0.9
1.1

0.9
1.1

2
2.1

2
2.1

2
2.1

2
2.1

2
2.1

–

–

–

–

–

8…3/0

8…3/0

8…3/0

18 - 14

18 - 14

18 - 14

0.42
0.48

1 x (0.75 - 16)
2 x (0.75 - 10)
1 x (0.75 - 16)
2 x (0.75 - 10)
1 x 16

1 x 16

18 - 6
–

18 - 6
–

1 x (0.75 - 16)
2 x (0.75 - 16)
1 x (0.75 - 35)
2 x (0.75 - 25)
1 x (16 - 50)
2 x (16 - 35)
12 - 2
12 - 2
2 x (6 x 9 x 0.8)

18 - 14

18 - 14

12 - 2

12 - 2

18 - 14

18 - 14

1 x (10 - 95)
2 x (10 - 70)
1 x (16 - 95)
2 x (16 - 70)
8…3/0
8…3/0
2 x (6 x 16 x 0.8)

1 x (0.75 - 4)
2 x (0.75 - 4)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)

18 - 14

18 - 14

18 - 14

18 - 14

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

105

1.1

Contactors
Basic devices up to 170 A

1 DILM7 ... DILM170

General
Main cable connection screw/bolt
Tightening torque
Control circuit cable connection screw/bolt
Tightening torque
Tools
Main conductors
Pozidriv screwdriver
Internal hexagon
Flat-blade screwdriver

Nm
Nm

SW

Size
mm
mm

DILM7

DILM9

DILM12

DILM15

DILM17

DILM25

M3.5
1.2
M3.5
1.2

M3.5
1.2
M3.5
1.2

M3.5
1.2
M3.5
1.2

M3.5
1.2
M3.5
1.2

M5
3.2
M3.5
1.2

M5
3.2
M3.5
1.2

2
–
0.8 x 5.5
1x6

2
–
0.8 x 5.5
1x6

2
–
0.8 x 5.5
1x6

2
–
0.8 x 5.5
1x6

2
–
0.8 x 5.5
1x6

2
–
0.8 x 5.5
1x6

Auxiliary conductors
Pozidriv screwdriver

Size

2

2

2

2

2

2

Flat-blade screwdriver

mm

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

mm²

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)

–

–

–

–

1 x (0.75 - 1.5)
2 x (0.75 - 1.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
18 - 14
18 - 14

–

–

–

–

–

–

–

–

18 - 14

18 - 14

Terminal type spring-cage terminal
Terminal capacity of main cable
Solid
Flexible

mm²

Flexible with ferrule

mm²

Flexible without ferrule

mm²

Solid or stranded
Terminal capacity of control circuit cable
Solid

AWG

18 - 14

mm²

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)

Flexible

mm²

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)

Flexible with ferrule

mm²

Flexible without ferrule

mm²

18 - 14

18 - 14

Solid or stranded
Tools
Strip length

AWG

1 x (0.75 - 1.5)
2 x (0.75 - 1.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
18 - 14
18 - 14

mm

10

10

10

10

10

10

Screwdriver blade width
Main contacts
Rated impulse withstand voltage
Overvoltage category/pollution degree
Rated insulation voltage
Rated operating voltage
Safe isolation according to EN 61140
Between coil and contacts

mm

3.5

3.5

3.5

3.5

3.5

3.5

U imp

V AC

Ui
Ue

V AC
V AC

8000
III/3
690
690

8000
III/3
690
690

8000
III/3
690
690

8000
III/3
690
690

8000
III/3
690
690

8000
III/3
690
690

V AC

400

400

400

400

440

440

V AC
A

400
112

400
112

400
144

400
155

440
238

440
350

A
A

70
70

90
90

120
120

124
124

170
170

250
250

A
A

50
40

70
50

100
70

100
70

170
120

250
150

gG/gL 500 V

A

20

20

20

20

35

35

gG/gL 690 V

A

16

16

20

20

35

35

gG/gL 500 V
gG/gL 690 V

A
A

35
20

35
20

35
25

63
50

63
50

100
50

Between the contacts
Making capacity (cos to IEC/EN 60947)
Breaking capacity

To 690 V

230 V
280/400 V
500 V
660/690 V
Short-circuit rating
Short-circuit protection rating maximum fuse
Type “2” coordination
400 V
690 V
Type “1” coordination
400 V
690 V

106

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

18 - 14

1.1

Contactors
Basic devices up to 170 A

1
DILM32

DILM38

DILM40

DILM50

DILM65

DILM72

DILM80

DILM95

DILM115

DILM150

DILM170

M5
3.2
M3.5
1.2

M5
3.2
M3.5
1.2

M6
3.3
M3.5
1.2

M6
3.3
M3.5
1.2

M6
3.3
M3.5
1.2

M6
3.3
M3.5
1.2

M10
14
M3.5
1.2

M10
14
M3.5
1.2

M10
14
M3.5
1.2

M10
14
M3.5
1.2

M10
14
M3.5
1.2

2
–
0.8 x 5.5
1x6

2
–
0.8 x 5.5
1x6

2
–
0.8 x 5.5
1x6

2
–
0.8 x 5.5
1x6

2
–
0.8 x 5.5
1x6

2
–
0.8 x 5.5
1x6

–
5
–

–
5
–

–
5
–

–
5
–

–
5
–

2

2

2

2

2

2

2

2

2

2

2

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

18 - 14

18 - 14

18 - 14

18 - 14

18 - 14

18 - 14

18 - 14

18 - 14

18 - 14

18 - 14

18 - 14

10

10

10

10

10

10

10

10

10

10

10

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

8000
III/3
690
690

8000
III/3
690
690

8000
III/3
690
690

8000
III/3
690
690

8000
III/3
690
690

8000
III/3
690
690

8000
III/3
690
690

8000
III/3
690
690

8000
III/3
690
690

8000
III/3
690
690

8000
III/3
690
690

440

440

440

440

440

440

690

690

690

690

690

440
384

440
384

440
560

440
700

440
910

440
910

690
1120

690
1330

690
1610

690
2100

690
2100

320
320

320
320

400
400

500
500

650
650

650
650

800
800

950
950

1150
1150

1500
1500

1500
1500

320
180

320
180

400
250

500
320

650
370

650
370

800
650

950
800

1150
1100

1500
1200

1500
1320

63

63

63

80

125

125

160

160

250

250

250

35

35

50

63

80

80

160

160

250

250

250

125
63

125
63

125
80

160
80

250
100

250
100

250
200

250
200

250
250

250
250

250
250

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
1 x (0.75 - 1.5)
2 x (0.75 - 1.5)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

107

1.1

Contactors
Basic devices up to 170 A

1 DILM7 ... DILM170
DILM7
AC voltage
AC-1 operation
Conventional free air
thermal current
3 pole
50 - 60 Hz

Conventional free air
thermal current 1 pole

Open

DILM9

DILM12

DILM15

DILM17

DILM25

at 50 °C

I th

A

22

22

22

22

40

45

at 50 °C

I th

A

21

21

21

21

38

43

at 55 °C
at 60 °C

I th
I th

A
A

21
20

21
20

21
20

21
20

37
35

42
40

Enclosed

I th

A

18

18

18

18

32

36

Open

I th

A

50

50

50

50

88

100

Enclosed

I th

A

45

45

45

45

80

90

220/230 V

Ie

A

7

9

12

15.5

18

25

240 V

Ie

A

7

9

12

15.5

18

25

380/400 V

Ie

A

7

9

12

15.5

18

25

415 V

Ie

A

7

9

12

15.5

18

25

440 V

Ie

A

7

9

12

15.5

18

25

500 V

Ie

A

5

7

10

12.5

18

25

660/690 V
220/230 V

Ie
P

A
kW

4
2.2

5
2.5

7
3.5

9
4

12
5

15
7.5

240 V

P

kW

2.2

3

4

4.6

5.5

8.5

380/400 V

P

kW

3

4

5.5

7.5

7.5

11

415 V

P

kW

4

5.5

7

8

10

14.5

440 V

P

kW

4.5

5.5

7.5

8.4

10.5

15.5

500 V

P

kW

3.5

4.5

7

7.5

12

17.5

660/690 V

P

kW

3.5

4.5

6.5

7

11

14

220/230 V

Ie

A

5

6

7

7

10

13

240 V

Ie

A

5

6

7

7

10

13

380/400 V

Ie

A

5

6

7

7

10

13

415 V

Ie

A

5

6

7

7

10

13

440 V
500 V

Ie
Ie

A
A

5
4.5

6
5

7
6

7
6

10
10

13
13

660/690 V
220/230 V

Ie
P

A
kW

4
1

4.5
1.5

5
2

5
2

8
2.5

10
3.5

240 V

P

kW

1.5

1.6

2.2

2.2

3

4

380/400 V

P

kW

2.2

2.5

3

3

4.5

6

415 V

P

kW

2.3

2.8

3.4

3.4

5

6.5

440 V

P

kW

2.4

3

3.6

3.6

5.5

7

500 V

P

kW

2.5

2.8

3.5

3.5

6

8

660/690 V

P

kW

2.9

3.6

4.4

4.4

6.5

8.5

AC-3 operation
Rated operational current
AC -3 open,
50 – 60 Hz, 3 pole

Rated operational power

AC-4 operation
Rated operational current
AC-4 open,
50 - 60 Hz, 3 pole

Rated operational powe

DC voltage

Switching of DC current Page 92

Operations
Rated operational current I e open

DC-1 operation

DC-3 operation

DC-5 operation

108

60 V

Ie

A

20

20

20

20

35

40

110 V

Ie

A

20

20

20

20

35

40

220 V
440 V

Ie
Ie

A
A

15
1

15
1.3

15
1.3

15
1.3

35
2.9

40
2.9

660 V

Ie

A

20

20

20

20

35

35

110 V

Ie

A

20

20

20

20

35

35

220 V

Ie

A

1.5

1.5

1.5

1.5

10

10

440 V

Ie

A

0.2

0.2

0.2

0.2

0.6

0.6

60 V

Ie

A

20

20

20

20

35

35

110 V

Ie

A

20

20

20

20

35

35

220 V

Ie

A

1.5

1.5

1.5

1.5

10

10

440 V

Ie

A

0.2

0.2

0.2

0.2

0.6

0.6

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Basic devices up to 170 A

1
DILM32

DILM38

DILM40

DILM50

DILM65

DILM72

DILM80

DILM95

DILM115

DILM150

DILM170

45

45

60

80

98

98

110

130

160

190

225

43

43

57

71

88

88

98

125

142

180

200

42
40

42
40

55
50

68
65

83
80

83
80

94
90

115
110

135
130

170
160

190
185

36

36

45

58

72

72

80

100

115

144

166

100

100

125

162

200

200

225

275

325

400

460

90

90

112

145

180

180

200

250

285

360

415

32

38

40

50

65

72

80

95

115

150

170

32

38

40

50

65

72

80

95

115

150

170

32

38

40

50

65

72

80

95

115

150

170

32

38

40

50

65

72

80

95

115

150

170

32

38

40

50

65

72

80

95

115

150

170

32

38

40

50

65

72

80

95

115

150

170

18
10

22.5
11

25
12.5

32
15.5

37
20

37
22

65
25

80
30

93
37

100
48

150
52

11

12

13.5

17

22

25

27.5

32

40

52

57

15

18.5

18.5

22

30

37

37

45

55

75

90

19

20

24

30

39

41

48

57

70

91

100

20

21

25

32

41

44

51

60

75

95

105

23

24

28

36

47

50

58

70

85

110

120

17

21

23

30

35

35

63

75

90

96

140

15

15

18

21

25

25

40

50

55

65

65

15

15

18

21

25

25

40

50

55

65

65

15

15

18

21

25

25

40

50

55

65

65

15

15

18

21

25

25

40

50

55

65

65

15
15

15
15

18
18

21
21

25
25

25
25

40
40

50
50

55
55

65
65

65
65

12
4

12
4

14
5

17
6

20
7

20
7

27
12

37
16

45
17

50
20

50
20

4.5

4.5

5.5

6.5

7.5

7.5

13

17

19

22

22

7

7

9

10

12

12

20

26

28

33

33

7.5

7.5

9.5

11

13

13

24

30

33

39

39

8

8

10

12

14

14

25

32

35

41

41

9

9

11

13

16

16

29

36

40

47

47

10

10

12

14

17

17

26

35

43

48

48

40

40

50

60

72

72

110

110

160

160

160

40

40

50

50

72

72

110

110

160

160

160

40
2.9

40
2.9

45
2.9

45
2.9

65
2.9

65
2.9

70
4.5

70
4.5

90
4.5

90
4.5

90
4.5

40

40

50

60

72

72

110

110

160

160

160

40

40

50

50

72

72

110

110

160

160

160

25

25

25

25

35

35

35

35

40

40

40

0.6

0.6

0.6

0.6

0.6

0.6

1

1

1

1

1

40

40

50

60

72

72

110

110

160

160

160

40

40

50

50

72

72

110

110

160

160

160

10

10

25

25

35

35

35

35

40

40

40

0.6

0.6

0.6

0.6

0.6

0.6

1

1

1

1

1

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

109

1.1

Contactors
Basic devices up to 170 A

1 DILM7 ... DILM170

Current heat loss (3 pole)
Current heat loss at I th

DILM7

DILM9

DILM12

DILM15

DILM17

DILM25

W

3

3

3

3

7.3

9.6

W
mȍ

0.37
2.5

0.6
2.5

1.1
2.5

1.8
2.5

1.9
2

3.8
2

Pick-up
Drop-out

x Uc
x Uc

0.8 - 1.1
0.3 - 0.6

0.8 - 1.1
0.3 - 0.6

0.8 - 1.1
0.3 - 0.6

0.8 - 1.1
0.3 - 0.6

0.8 - 1.1
0.3 - 0.6

0.8 - 1.1
0.3 - 0.6

Pick-up
Drop-out

x Uc
x Uc

0.8 - 1.1
0.15 - 0.6

0.8 - 1.1 1)
0.15 - 0.6

0.8 - 1.1 1)
0.15 - 0.6

0.8 - 1.1 1)
0.15 - 0.6

0.7 - 1.2 2)
0.15 - 0.6

0.7 - 1.2 2)
0.15 - 0.6
52

Current heat loss at Ie to AC-3/400 V
Impedance per pole
Magnet systems
Voltage tolerance
AC operated
AC operated
DC operated 3)
DC operated 3)
Power consumption of the coil in a cold state and 1.0 x Uc
50 Hz

Pick-up

VA

24

24

24

24

52

50 Hz

Sealing

VA

3.4

3.4

3.4

3.4

7.1

7.1

50 Hz

Sealing

W

1.2

1.2

1.2

1.2

2.1

2.1

60 Hz
60 Hz

Pick-up
Sealing

VA
VA

30
4.4

30
4.4

30
4.4

30
4.4

67
8.7

67
8.7

60 Hz
50/60 Hz

Sealing
Pick-up

W
VA

50/60 Hz

Sealing

VA

50/60 Hz

Sealing

W

1.4
27
25
4.2
3.3
1.4
1.2
3

1.4
27
25
4.2
3.3
1.4
1.2
3

1.4
27
25
4.2
3.3
1.4
1.2
4.5

1.4
27
25
4.2
3.3
1.4
1.2
4.5

2.6
62
58
9.1
6.5
2.5
2
12

2.6
62
58
9.1
6.5
2.5
2
12

DC operated

Pick-up

W

DC operated

Sealing

W

3

3

4.5

4.5

0.5

0.5

% DF

100

100

100

100

100

100

15…21
9…18

15…21
9…18

15…21
9…18

15…21
9…18

16…22
8…14

16…22
8…14

Duty factor
Changeover times at 100 % Uc (recommended values)
Main contacts

AC operated

Closing delay
Opening delay

ms
ms

DC operated

Closing delay

ms

31

31

31

31

47

47

Opening delay

ms

12

12

12

12

30

30

ms
mA

10
–

10
–

10
–

10
–

10
–

10
–

Arcing time
Permissible residual current when A1 - A2 are
actuated from the electronic system (with 0 signal)
Lifespan, mechanical; Coil 50/60 Hz

At 50 Hz

Mechanical lifespan at 50 Hz approx. 30% lower than under

Technical data general

Electromagnetic compatibility (EMC)
Emitted interference

To EN 60947-1

Interference immunity

To EN 60947-1

Notes

1) At 24 V DC: 0.7 – 1.3 without auxiliary contact
2) RDC 24 (Umin 24 V DC/Umax 27 V DC)

module and at ambient temperature + 40 °C

RDC 60 (Umin 48 V DC/Umax 60 V DC)
RDC 130 (Umin 110 V DC/Umax 130 V DC)
RDC 240 (Umin 200 V DC/Umax 240 V DC)
Example: Uc = 0.7 x Umin - 1.2 x Umax / Uc = 0.7 x 24 V - 1.2 x 27 V DC
3) At least: smoothed two-phase bridge rectifier or three-phase rectifier

110

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Basic devices up to 170 A

1
DILM32

DILM38

DILM40

DILM50

DILM65

DILM72

DILM80

DILM95

DILM115

DILM150

DILM170

12.1

12.1

11.3

19

28.8

28.8

12.2

18.2

20.3

30.7

41.1

6.1
2

6.1
2

7.2
1.5

11.3
1.5

19
1.5

23
1.5

9.6
0.5

13.5
0.5

15.9
0.4

27
0.4

34.7
0.4

0.8 - 1.1
0.3 - 0.6

0.8 - 1.1
0.3 - 0.6

0.8 - 1.1
0.3 - 0.6

0.8 - 1.1
0.3 - 0.6

0.8 - 1.1
0.3 - 0.6

0.8 - 1.1
0.3 - 0.6

0.8 - 1.1
0.3 - 0.6

0.8 - 1.1
0.3 - 0.6

0.8 - 1.15
0.25 - 0.6

0.8 - 1.15
0.25 - 0.6

0.8 - 1.15
0.25 - 0.6

0.7 - 1.2 2)
0.15 - 0.6

0.7 - 1.2 2)
0.15 - 0.6

0.7 - 1.2 2)
0.15 - 0.6

0.7 - 1.2 2)
0.15 - 0.6

0.7 - 1.2 2)
0.15 - 0.6

0.7 - 1.2 2)
0.15 - 0.6

0.7 - 1.2 2)
0.15 - 0.6

0.7 - 1.2 2)
0.15 - 0.6

0.7 - 1.2 2)
0.15 - 0.6

0.7 - 1.2 2)
0.15 - 0.6

0.7 - 1.2 2)
0.15 - 0.6

52

52

149

149

149

149

310

310

180

180

180

7.1

7.1

16

16

16

16

26

26

3.1

3.1

3.1

2.1

2.1

4.3

4.3

4.3

4.3

5.8

5.8

2.1

2.1

2.1

67
8.7

67
8.7

178
19

178
19

178
19

178
19

345
30

345
30

170
3.1

170
3.1

170
3.1

2.6
62
58
9.1
6.5

2.6
62
58
9.1
6.5

5.3
168
154
22
14

5.3
168
154
22
14

5.3
168
154
22
14

5.3
168
154
22
14

7.1
372
328
37.1
22.6

7.1
372
328
37.1
22.6

2.1
170
170
3.1
3.1

2.1
170
170
3.1
3.1

2.1
170
170
3.1
3.1

2.5
2
12

2.5
2
12

5.3
4.3
24

5.3
4.3
24

5.3
4.3
24

5.3
4.3
24

7.5
6.1
90

7.5
6.1
90

2.1
2.1
149

2.1
2.1
149

2.1
2.1
149

0.5

0.5

0.5

0.5

0.5

0.5

1.3

1.3

2.1

2.1

2.1

100

100

100

100

100

100

100

100

100

100

100

16…22
8…14

16…22
8…14

12…18
8…13

12…18
8…13

12…18
8…13

12…18
8…13

14…20
9…14

14…20
9…14

28…33
35…41

28…33
35…41

28…33
35…41

47

47

54

54

54

54

45

45

35

35

35

30

30

24

24

24

24

34

34

30

30

30

10
–

10
–

10
–

10
–

10
–

10
–

15

15

15

15

Mechanical lifespan at 50 Hz approx. 30% lower than under

1

1

15
1

1

Technical data general

To EN 60947-1
To EN 60947-1

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

111

1.1

Contactors
Comfort devices and standard devices greater than 170 A

1 DILM185...DILM1600, DILH
Contactors
DILM185A

DILM225A

DILM250

DILM300A

DILM400

DILM500

DILM570

General
Standards
Lifespan, mechanical

IEC/EN 60947, VDE 0660, UL, CSA

AC operated

c (contacts)

x 10 6

10

10

10

10

7

7

7

DC operated

c (contacts)

x 10 6

10

10

10

10

7

7

7

3000
3000

3000
3000

3000
3000

3000
3000

2000
2000

2000
2000

2000
2000

Operating frequency, mechanical
AC operated
DC operated

Operations/h
Operations/h

Maximum operating frequency
Electrical (Contactor without overload relay)
Climatic proofing

Engineering Page 91
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Ambient temperature
Open

°C

-25…60

-25…60

-25…60

-25…60

-25…60

-25…60

-25…60

Enc losed

°C

-25…40

-25…40

-25…40

-25…40

-25…40

-25…40

-25…40

°C

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

10

10

10

30°

30°

180°

°

90

90

°

Storage
Mounting position: AC and DC-actuated

Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 ms
Main contacts
N/O
Auxiliary contacts

g

N/O

g

10

10

10

10

10

10

10

NC

g

8

8

8

8

8

8

8

IP00
IP00
IP00
IP00
IP00
Finger- and back-of-hand proof with cover or terminal block

IP00

IP00

kg

3.2

3.2

6.5

6.5

8

8

8

Flexible with cable lug

mm²

50 - 185

50 - 185

50 - 240

50 - 240

50 - 240

50 - 240

50 - 240

Stranded with cable lug

mm²

50 - 185

70 - 185

70 - 240

70 - 240

70 - 240

70 - 240

70 - 240

Solid or stranded

AWG

1/0 - 350
MCM
32

2/0 - 250
MCM
32

2/0 - 500
MCM
25

2/0 - 500
MCM
25

2/0 - 500
MCM
25

2/0 - 500
MCM
30

2/0 - 500
MCM
30

Protection type
Protection against direct contact when actuated
from front (EN 90274)
Weight
Weight
Terminal capacity of main cable

Busbar

Width

mm

Main cable connection screw/bolt

10

10

10

10

M10

M10

M10

M10

M10

M10

M10

Nm

24

24

24

24

24

24

24

Solid

mm²

Flexible with ferrule

mm²

Solid or stranded

AWG

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
2 x (18 - 12) 2 x (18 - 12)

2 x (18 - 12)

2 x (18 - 12)

2 x (18 - 12)

2 x (18 - 12)

2 x (18 - 12)

Nm

M3.5
1.2

M3.5
1.2

M3.5
1.2

M3.5
1.2

M3.5
1.2

M3.5
1.2

M3.5
1.2

mm

16

16

16

16

16

16

16

Size

2

2

2

2

2

2

2

Tightening torque
Terminal capacity of control circuit cable

Control circuit cable connection screw/bolt
Tightening torque
Tools
Main conductors
Wrench
Auxiliary conductors
Pozidriv screwdriver

112

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Comfort devices and standard devices greater than 170 A

1
DILM580

DILM650

DILM750

DILM820

DILM1000

DILM1600

DILH1400

DILH2000

DILH2200

DILH2600

IEC/EN 60947, VDE 0660, UL, CSA
5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

Engineering Page 91
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
-25…60

-25…60

-25…60

-25…60

-25…60

-25…60

-25…60

-25…60

-25…60

-25…60

-25…40

-25…40

-25…40

-25…40

-25…40

-25…40

-25…40

-25…40

-25…40

-25…40

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

-40 - 80

°

90

°

90

30°

30°

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

8

8

8

8

8

8

8

8

8

8

IP00
IP00
IP00
IP00
Finger- and back-of-hand proof with cover or terminal block

IP00

IP00

IP00

IP00

IP00

IP00

15

15

15

15

15

32

15

32

32

32

50 - 240

50 - 240

50 - 240

50 - 240

50 - 240

–

–

–

–

–

70 - 240

70 - 240

70 - 240

70 - 240

70 - 240

–

–

–

–

–

2/0 - 500 MCM

2/0 - 500 MCM

2/0 - 500 MCM

2/0 - 500 MCM

2/0 - 500 MCM

–

–

–

–

–

50

50

60

60

60

100

80

100

100

100

M10

M10

M12

M12

M12

M12

M12

M12

M12

M12

24

24

35

35

35

35

35

35

35

35

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
2 x (18 - 12)

2 x (18 - 12)

2 x (18 - 12)

2 x (18 - 12)

2 x (18 - 12)

2 x (18…12)

2 x (18 - 12)

2 x (18 - 12)

2 x (18 - 12)

2 x (18 - 12)

M3.5
1.2

M3.5
1.2

M3.5
1.2

M3.5
1.2

M3.5
1.2

M3.5
1.2

M3.5
1.2

M3.5
1.2

M3.5
1.2

M3.5
1.2

16

16

18

18

18

18

18

18

18

18

2

2

2

2

2

2

2

2

2

2

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

113

1.1

Contactors
Comfort devices and standard devices greater than 170 A

1 DILM185...DILM1600, DILH
Contactors
Main contacts
Rated impulse withstand voltage
Overvoltage category/pollution degree

Rated insulation voltage
Rated operating voltage
Safe isolation according to EN 61140
Between coil and contacts
Between the contacts
Making capacity (cos to IEC/EN 60947)
Breaking capacity
220/230 V

DILM185A

DILM225A

DILM250

DILM300A

DILM400

DILM500

DILM570

U imp

V AC

8000
III/3

8000
III/3

8000
III/3

8000
III/3

8000
III/3

8000
III/3

8000
III/3

Ui
Ue

V AC
V AC

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

V AC
V AC
A

500
500
2700

500
500
2700

500
500
3000

500
500
3600

500
500
5500

500
500
5500

500
500
6000

A

2250

2250

2500

3000

5000

5000

5800

A
A
A
A

2250
2250
2250
760
Page 87

2250
2250
2250
760

2500
2500
2500
760

3000
3000
3000
950

5000
5000
5000
950

5000
5000
5000
950

5800
5800
5800
950

gG/gL 500 V
gG/gL 690 V
gG/gL 1000 V

A
A
A

250
250
160

250
250
160

315
315
160

315
315
160

500
500
200

500
500
200

500
500
200

gG/gL 500 V
gG/gL 690 V
gG/gL 1000 V

A
A
A

400
315
200

400
315
200

400
400
200

400
400
200

630
630
250

630
630
250

800
630
250

I th

A

337

356

400

430

612

857

920

I th
I th
I th
I th

A
A
A
A

301
287
275
245

310
295
285
275

360
340
330
300

385
365
350
315

548
522
500
450

767
731
700
650

821
783
750
–

A
A

685
625

707
636

825
742

875
785

1250
1125

1750
1600

1875
–

380/440 V
500 V
660/690 V
1000 V
Component lifespan
Short-circuit rating
Short-circuit protection rating maximum fuse
Type “2” coordination
400 V
690 V
1000 V
Type “1” coordination
400 V
690 V
1000 V
AC voltage
AC-1 operation
Conventional thermal current 3 pole 50 - 60 Hz
Open
at 40 °C
at 50 °C
at 55 °C
at 60 °C
Enclosed 1)
Conventional thermal current, 1-pole

Open1)
I th
I th
Enclosed 1)
AC-3 operation
Rated operational current AC -3 open, 50 – 60 Hz, 3 pole
220/230 V
240 V
380/400 V

Ie
Ie
Ie

A
A
A

185
185
185

225
225
225

250
250
250

300
300
300

400
400
400

500
500
500

580
580
580

415 V
440 V
500 V

Ie
Ie
Ie

A
A
A

185
185
185

225
225
225

250
250
250

300
300
300

400
400
400

500
500
500

580
580
500

Ie
Ie

A
A

150
76

160
76

250
76

210
95

360
95

360
95

360
95

220/230 V

P

kW

55

70

75

90

125

155

185

240 V
380/400 V
415 V

P
P
P

kW
kW
kW

62
90
110

75
110
132

85
132
148

100
160
180

132
200
240

170
250
300

200
315
348

440 V
500 V
660/690 V
1000 V

P
P
P
P

kW
kW
kW
kW

115
132
140
108

138
160
150
108

132
180
240
108

185
215
195
132

200
290
344
132

250
360
344
132

370
360
344
132

660/690 V
1000 V
Rated operational power

Notes

1)
2)

114

At maximum permissible ambient air temperature
To 690 V

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Comfort devices and standard devices greater than 170 A

1
DILM580

DILM650

DILM750

DILM820

DILM1000

DILM1600

DILH1400

DILH2000

DILH2200

DILH2600

8000
III/3

8000
III/3

8000
III/3

8000
III/3

8000
III/3

8000
III/3

8000
III/3

8000
III/3

8000
III/3

8000
III/3

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

1000
1000

500
500
7800

500
500
7800

500
500
9840

500
500
9840

500
500
9840

500
500
19000

500
500
9840

500
500
9840

500
500
9840

500
500
9840

6500

6500

8200

8200

8200

16000

8200

8200

8200

8200

6500
6500
6500
4350
Page 87

6500
6500
6500
4350

8200
8200
8200
5800

8200
8200
8200
5800

8200
8200
8200
5800

16000
16000
16000
5800

8200
8200
8200
5800

8200
8200
8200
5800

8200
8200
8200
5800

8200
8200
8200
5800

630
630
500

630
630
500

630
630
630

630
630
630

630
630
630

–
–
–

–
–
–

–
–
–

–
–
–

–
–
–

1000
1000
630

1000
1000
630

1200
1200
800

1200
1200
800

1200
1200
800

–
–
–

–
–
–

–
–
–

–
–
–

–
–
–

980

1041

1102

1225

1225

2200 2)

1714 2)

2450 2)

2700 2)

3185 2)

876
836
800
–

931
888
850
–

986
940
900
–

1095
1044
1000
–

1095
1044
1000
–

1970 2)
1880 2)
1800 2)
–

1533 2)
1462 2)
1400 2)
–

2190 2)
2089 2)
2000 2)
–

2400 2)
2300 2)
2200 2)
–

2847 2)
2716 2)
2600 2)
–

2000
–

2125
–

2250
–

2500
–

2500
–

4500
–

3500
–

5000
–

5500
–

6500 2)
–

580
580
580

650
650
650

750
750
750

820
820
820

1000
1000
1000

1600
1600
1600

–
–
–

–
–
–

–
–
–

–
–
–

580
580
580

650
650
650

750
750
750

820
820
820

1000
1000
1000

1600
1600
1600

–
–
–

–
–
–

–
–
–

–
–
–

580
435

650
435

750
580

820
580

1000
750

1600
1200

–
–

–
–

–
–

–
–

185

205

240

260

315

500

–

–

–

–

200
315
348

225
355
390

260
400
455

285
450
500

340
560
610

550
900
930

–
–
–

–
–
–

–
–
–

–
–
–

370
420
560
600

420
470
630
600

480
550
720
800

450
600
750
800

650
730
1000
1100

1000
1180
1600
1770

–
–
–
–

–
–
–
–

–
–
–
–

–
–
–
–

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

115

1.1

Contactors
Comfort devices and standard devices greater than 170 A

1 DILM185...DILM1600, DILH
Contactors
DILM185A

DILM225A

DILM250

DILM300A

DILM400

DILM500

DILM570

AC voltage
AC-4 operation
Rated operational current AC -4 open, 50 – 60 Hz, 3 pole
220/230 V
240 V

Ie
Ie

A
A

136
136

164
164

200
200

240
240

296
296

360
360

360
360

380/400 V

Ie

A

136

164

200

240

296

360

360

415 V

Ie

A

136

164

200

240

296

360

360

440 V

Ie

A

136

164

200

240

296

360

360

500 V

Ie

A

136

164

200

240

296

360

360

660/690 V
1000 V

Ie
Ie

A
A

110
55

120
55

200
76

170
76

296
95

296
95

296
95

220/230 V
240 V

P
P

kW
kW

41
45

51
54

62
68

75
82

92
101

112
122

112
122

380/400 V

P

kW

75

90

110

132

160

200

200

415 V

P

kW

80

96

117

142

176

216

216

440 V

P

kW

85

102

125

150

186

229

229

500 V
660/690 V

P
P

kW
kW

96
102

116
110

143
189

172
160

214
283

260
344

260
344

1000 V

P

kW

77

77

108

109

132

132

132

Rated operational power

Capacitor operation
Individual compensation rated operational
current I e of alternating current capacitor
Open
To 525 V

A

220

220

220

307

307

307

307

690 V

A

133

133

133

177

177

177

177

x Ie
x 10 6

30
0.1

30
0.1

30
0.1

30
0.1

30
0.1

30
0.1

30
0.1

Ops/h

200

200

200

200

200

200

200

Max. peak inrush current
Component lifespan

c (contacts)

Max. operating frequency
DC voltage
Operations

Engineering Page 92

Rated operational current I e open
DC-1 operation
60 V

Ie

A

300

300

300

400

400

400

400

110 V

Ie

A

300

300

300

400

400

400

400

220 V
440 V

Ie
Ie

A
A

300
11

300
11

300
11

400
11

400
11

400
11

400
11

60 V

Ie

A

300

300

300

400

400

400

400

110 V

Ie

A

300

300

300

400

400

400

400

220 V
DC-5 operation

Ie

A

300

300

300

400

400

400

400

60 V

Ie

A

300

300

300

400

400

400

400

110 V

Ie

A

300

300

300

400

400

400

400

Ie

A

300

300

300

400

400

400

400

Current heat loss at Ith

W

34

45

55

37

58

113

130

Current heat loss at Ie to AC-3/400 V

W

16

23

28

21

37

58

78

DC-3 operation

220 V
Current heat loss (3 pole)

116

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Comfort devices and standard devices greater than 170 A

1
DILM580

DILM650

DILM750

DILM820

DILM1000

DILM1600

DILH1400

DILH2000

DILH2200

DILH2600

456
456

512
512

576
576

656
656

800
800

1280
1280

–
–

–
–

–
–

–
–

456

512

576

656

800

1280

–

–

–

–

456

512

576

656

800

1280

–

–

–

–

456

512

576

656

800

1280

–

–

–

–

456

512

576

656

800

1280

–

–

–

–

456
348

512
348

576
464

656
464

800
700

1280
1120

–
–

–
–

–
–

–
–

143
156

161
176

181
200

209
228

260
280

430
450

–
–

–
–

–
–

–
–

250

280

315

355

450

750

–

–

–

–

274

307

346

394

490

770

–

–

–

–

290

326

367

418

520

830

–

–

–

–

330
440

370
494

417
556

474
633

590
780

940
1300

–
–

–
–

–
–

–
–

509

509

678

678

1000

1650

–

–

–

–

463

463

463

463

463

–

–

–

–

–

265

265

265

265

265

–

–

–

–

–

30
0.1

30
0.1

30
0.1

30
0.1

30
0.1

–
–

–
–

–
–

–
–

–
–

200

200

200

200

200

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–
–

–
–

–
–

–
–

–
–

–
–

–
–

–
–

–
–

–
–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

61

69

78

96

96

155

188

192

232

250

32

41

54

65

96

123

–

–

–

–

–

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

117

1.1

Contactors
Comfort devices and standard devices greater than 170 A

DILM185...DILM1600, DILH
Contactors

1
Magnet systems
Voltage tolerance 1)

AC operated
AC operated
DC operated

Power consumption of the
coil in a cold state and
1.0 x Uc

DC operated
50/60 Hz
50/60 Hz
50/60 Hz
DC operated
DC operated
Comfort series
DILM…
Standard range
DILM…-S
Comfort series
DILM…
Standard range
DILM…-S

Voltage tolerance

Power consumption of the
coil in a cold state and
1.0 x Uc

Comfort series
DILM…
Comfort series
DILM…
Comfort series
DILM…
Comfort series
DILM…
Standard range
DILM…-S
Standard range
DILM…-S
Standard range
DILM…-S
Standard range
DILM…-S

(0 - 0.2 x Uc min )

DILM225A

DILM250

Excess voltage

Pick-up phase

Notes

DILM570

–
–
–
–
–

–
–
–
–
–

–
–
–
–
–

0.8 - 1.15
0.25 - 0.6
0.7 - 1.2
0.15 - 0.6
210
2.6
2.6
180
2.1
–

–
–
–
–
–
–
–
–
–
–
0.7 x U c min - 1.15 x U c max

Pick-up

x Uc

–

–

0.85 x U c min - 1.1 x U c max

Drop-out

x Uc

–

–

0.2 x U c min - 0.6 x U c min

Drop-out

x Uc

–

–

0.2 x U c min - 0.4 x U c min

Pick-up

VA

–

–

380 2)

380 2)

450 2)

450 2)

450 2)

Pick-up

W

–

–

250

250

350

350

350

Sealing

VA

–

–

4.3

4.3

4.3

4.3

4.3

Sealing

W

–

–

3.3

3.3

3.3

3.3

3.3

Pick-up

VA

–

–

360 4)

360 4)

715 4)

715 4)

715 4)

Pick-up

W

–

–

325

625

645

645

645

Sealing

VA

–

–

4.3

4.3

4.3

4.3

4.3

Sealing

W

–

–

3.3

3.3

3.3

3.3

3.3

% DF

–

–

100

100

100

100

100

ms
ms
ms
ms

–
–
< 60
< 40

–
–
< 60
< 40

< 100
< 110
< 55
< 40

< 80
< 110
< 55
< 40

< 80
< 110
< 55
< 50

< 80
< 110
< 55
< 50

< 80
< 110
< 55
< 50

–

–

Targeted bridging during this time
Drop-out of the contactor
Targeted bridging during this time
Drop-out of the contactor
Contactor remains switched on
Contactor remains switched on
Contactor remains switched on
Drop-out of the contactor
Contactor does not switch on
Contactor switches on safely
Contactor switches on safely

mȍ

–

–

500

500

500

500

–

mA

–

–

1

1

1

1

–

V
V

15
5

15
5

15
5

15
5

15
5

15
5

–
–

(0 - 0.2 x Uc min ) 12 ms
(0.2 - 0.6 x U c min ) > 12 ms
(0.6 - 0.7 x U c min )
(1.15 - 1.3 x Uc max )
(> 1.3 x U c max ) 3 s
(> 1.3 x U c max ) > 3 s
(0.7 x Uc min )
(0.7 x U c min - 1.15 x U c max )
(> 1.15 x U c max )

This product is designed for operation in industrial environments (environment 2).
The use in residential environments (environment 1) could cause electrical interference so
that addition suppression must be planned.
1)

Uc min, Uc max,
Control transformer with u k 0.6
3) Control transformer with u
k 0.7
4) u
k 10 %

2)

118

DILM500

0.8 - 1.15
0.25 - 0.6
0.7 - 1.2
0.15 - 0.6
210
2.6
2.6
180
2.1
–

10 ms

Permissible transitional contact resistance
(of external control unit when A11 is actuated)
Permissible residual current ( when A11 is
actuated from the electronic system in the event
of a 0 signal)
PLC signal level (A3 - A4) to IEC/EN 61131-2 (part no. 2)
H ig h
Low
Electromagnetic compatibility (EMC)
Electromagnetic compatibility

DILM400

x Uc
x Uc
x Uc
x Uc
VA
VA
W
W
W
x Uc

(0 - 0.2 x U c min ) > 10 ms

Voltage drops

DILM300A

Pick-up
Drop-out
Pick-up
Drop-out
Pick-up
Sealing
Sealing
Pick-up
Sealing
Pick-up

D u ty fa c to r
Changeover time at 100 % U c (recommended values), main circuit
Closing delay
Comfort series
DILM…
Opening delay
Standard range
Closing delay
DILM…-S
Opening delay
Behavior in limit range and transition area, hold state

Voltage interruption

DILM185A

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Comfort devices and standard devices greater than 170 A

DILM580

DILM650

–
–
–
–
–
–
–
–
–
–
0.7 x U c min - 1.15 x U c max

DILM750

DILM820

DILM1000

DILM1600

DILH1400

DILH2000

DILH2200

DILH2600

–
–
–
–
–

–
–
–
–
–

–
–
–
–
–

–
–
–
–
–

–
–
–
–
–

–
–
–
–
–

–
–
–
–
–

–
–
–
–
–

1

0.85 x U c min - 1.1 x U c max
0.2 x U c min - 0.6 x U c min
0.2 x U c min - 0.4 x U c min
800 3)

800 3)

800 3)

800 3)

800 3)

1600 3)

800 3)

1600 3)

1600 3)

–

700

700

700

700

700

1400

700

1400

1400

–

7.5

7.5

7.5

7.5

7.5

15

7.5

15

15

–

6.5

6.5

6.5

6.5

6.5

13

6.5

13

13

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

100

100

100

100

100

100

100

100

100

100

< 70
< 110
–
–

< 70
< 110
–
–

< 70
< 110
–
–

< 70
< 110
–
–

< 70
< 110
–
–

< 70
< 40
–
–

< 70
< 40
–
–

< 70
< 40
–
–

< 70
< 40
–
–

–
–
–
–

Targeted bridging during this time
Drop-out of the contactor
Targeted bridging during this time
Drop-out of the contactor
Contactor remains switched on
Contactor remains switched on
Contactor remains switched on
Drop-out of the contactor
Contactor does not switch on
Contactor switches on safely
Contactor switches on safely

15
5

500

500

500

500

500

500

500

500

500

500

1

1

1

1

1

1

1

1

1

1

15
5

15
5

15
5

15
5

15
5

15
5

15
5

15
5

15
5

This product is designed for operation in industrial environments (environment 2). The use in residential environments (environment 1) could cause electrical interference
so that addition suppression must be planned.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

119

1.1

Contactors
Basic devices up to 200 A, 4 pole

DILMP20 ... DILMP200
DILMP20

1

DILMP32

DILMP63

DILMP125

DILMP45

DILMP80

DILMP160
DILMP200

General
Standards
Lifespan, mechanical
AC operated
DC operated
Operating frequency, mechanical
Mechanical, AC operated
DC operated
Maximum operating frequency
Electrical (Contactor without overload relay)
Climatic proofing

IEC/EN 60947, VDE 0660, UL, CSA
c (contacts)
c (contacts)

x 10 6
x 10 6

Operations/h
Operations/h

10
10
5000
5000

3600
3600

600
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-30

Ambient temperature
°C
°C
°C

-25…60
-25…40
-40 - 80

90

90

°

Open
Enclosed
Storage
Mounting position AC- and DC operated

30°

180°

°

30°

Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 ms
Main contacts
N/O
Auxiliary contacts
N/O
NC
Protection type
With accessories
Protection against direct contact when actuated from front (EN 50274)
Terminal type, screw connection
Terminal capacity of main cable
Solid

g

10

g
g

7
5
IP20
IP00
–
IP20
Finger- and back-of-hand proof

mm²

1 x (0.75 - 16)
2 x (0.75 - 10)
1 x (0.75 - 16)
2 x (0.75 - 10)
1 x 16

Flexible with ferrule

mm²

Stranded

mm²

1 x (0.75 - 4)
2 x (0.75 - 2.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
–

AWG
mm

18 - 14
–

18 - 6
–

mm²

Nm

1 x (0.75 - 4)
2 x (0.75 - 2.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
18 - 14
M3.5
1.2
M3.5
1.2

1 x (0.75 - 4)
2 x (0.75 - 2.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
18 - 14
M5
3
M3.5
1.2

1 x (0.75 - 4)
2 x (0.75 - 4)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
18 - 14
M6
3.3
M3.5
1.2

1 x (0.75 - 4)
2 x (0.75 - 4)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
18 - 14
M10
14
M3.5
1.2

Size
mm

2
–

2
–

2
–

–
5

mm

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

–

Size
mm

2
0.8 x 5.5
1x6

2
0.8 x 5.5
1x6

2
0.8 x 5.5
1x6

2
0.8 x 5.5
1x6

Solid or stranded
Flat conductor

Number of
layers x width x
thickness

Terminal capacity of control circuit cable
Solid
Flexible with ferrule

mm²

Solid or stranded
Main cable connection screw/bolt
Tightening torque
Control circuit cable connection screw/bolt
Tightening torque
Tools
Main conductors
Pozidriv screwdriver
Internal hexagon
Flat-blade screwdriver

AWG
Nm

SW

1 x (2.5 - 16)
2 x (2.5 - 16)
1 x (2.5 - 35)
2 x (2.5 - 25)
1 x (16 - 50)
2 x (16 - 35)
12 - 2
2x
(6 x 9 x 0.8)

–
1 x (10 - 95)
2 x (10 - 70)
1 x (16 - 120)
2 x (16 - 95)
8 - 250MCM
2x
(6 x 16 x 0.8)

Auxiliary conductors
Pozidriv screwdriver
Flat-blade screwdriver
120

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Basic devices up to 200 A, 4 pole
DILMP20 ... DILMP200
DILMP20

DILMP32

DILMP63

DILMP125

DILMP45

DILMP80

DILMP160

1

DILMP200
Main contacts
Rated impulse withstand voltage
Overvoltage category/pollution degree
Rated insulation voltage
Rated operating voltage
Safe isolation according to EN 61140
Between coil and contacts
Between the contacts
Making capacity (cos to IEC/EN 60947)
Breaking capacity
220/230 V
380/400 V
500 V
660/690 V
Short-circuit rating
Short-circuit protection rating maximum fuse
Type “2” coordination
400 V
690 V
Type “1” coordination
400 V
690 V
AC voltage
AC-1 operation
Conventional thermal current 3 pole 50 - 60 Hz
Open
at 40 °C
at 50 °C
at 60 °C
Enclosed
Conventional thermal current, 1 pole
Open
Enclosed
Rated operational power
220/230 V
240 V
380 V
415 V
440 V
500 V
690 V
AC-3 operation
Rated operational current AC -3 open, 50 – 60 Hz, 3 pole
220/230 V
240 V
380/400 V
415 V
440 V
500 V
660/690 V
Rated operational power
220/230 V
240 V
380/400 V
415 V
440 V
500 V
660/690 V

U imp

V AC

Ui
Ue

V AC
V AC

8000
III/3
690
690

To 690 V

V AC
V AC
A

400
400
144

440
440
238

350

560

700

1120

1330

1800

A
A

120
120

180
180

250
250

400
400

500
500

800
800

950
950

1150
1150

A
A

100
70

180
120

250
144

400
250

500
296

800
650

950
750

1150
800

gG/gL 500 V
gG/gL 690 V

A
A

20
20

35
35

35
35

63
50

80
63

160
160

160
160

250
200

gG/gL 500 V
gG/gL 690 V

A
A

35
25

63
50

100
50

125
80

160
80

250
200

250
200

250
200

I th
I th
I th
I th

A
A
A
A

22
21
20
18

32
30
28
27

45
41
39
36

63
60
54
50

80
76
69
64

125
116
108
100

160
150
138
128

200
188
172
160

I th
I th

A
A

60
54

84
76

117
105

162
146

207
186

325
292

415
373

516
464

P
P
P
P
P
P
P

kW
kW
kW
kW
kW
kW
kW

8
9
14
15
16
18
24

12
13
20
22
23
26
35

16
18
28
31
33
37
49

23
25
39
43
46
52
68

29
32
50
55
58
66
87

45
49
78
85
90
103
136

58
63
100
109
116
132
174

72
79
125
137
145
165
217

Ie
Ie
Ie
Ie
Ie
Ie
Ie

A
A
A
A
A
A
A

12
12
12
12
12
10
7

18
18
18
18
18
18
12

25
25
25
25
25
25
15

40
40
40
40
40
40
25

50
50
50
50
50
50
32

80
80
80
80
80
80
65

95
95
95
95
95
95
80

115
115
115
115
115
115
93

P
P
P
P
P
P
P

kW
kW
kW
kW
kW
kW
kW

3.5
4
5.5
7
7.5
7
6.5

5
5.5
7.5
10
10.5
12
11

7.5
8.5
11
14.5
15.5
17.5
14

12.5
13.5
18.5
24
25
28
23

15.5
17
22
30
32
36
30

25
27.5
37
48
51
58
63

30
33
45
57
60
70
75

37
40
55
70
75
85
90

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

121

1.1

Contactors
Basic devices up to 200 A, 4 pole

1 DILMP20 ... DILMP200
DILMP20

DILMP32

DILMP63

DILMP45

DILMP125

DILMP80

DILMP160
DILMP200

DC voltage
Rated operational current I e open
DC-1 operation
60 V

Ie

A

22

32

45

63

80

125

160

200

110 V

Ie

A

22

32

45

63

80

125

160

200

220 V

Ie

A

6

32

45

63

80

125

160

200

440 V
DC-3 operation

Ie

A

1.3

3

3

5

5

10

10

10
200

60 V

Ie

A

20

32

45

63

80

125

160

110 V

Ie

A

20

32

45

63

80

125

160

200

220 V

Ie

A

1.5

32

45

63

80

125

160

200

440 V
DC-5 operation

Ie

A

0.2

6

6

8

8

9

9

9

60 V

Ie

A

20

32

45

63

80

125

160

200

110 V
220 V

Ie
Ie

A
A

20
1.5

25
15

32
22

50
38

80
70

125
100

160
125

200
150

440 V

Ie

A

0.2

4

4

8

8

8

8

8

W
mȍ

4.7
2.5

8.2
2

12
1.5

16
1

23
0.7

29
0.6

46
0.6

60
0.5

x Uc

0.8 - 1.1

0.8 - 1.1

0.8 - 1.1

x Uc

0.8 - 1.1

0.85 - 1.1

0.85 - 1.1

0.8 - 1.1

Drop-out
Pick-up

x Uc
x Uc

0.4 - 0.6
0.8 - 1.1

0.4 - 0.6
0.7 - 1.2

0.4 - 0.6
0.7 - 1.2

0.4 - 0.6
0.7 - 1.2

Drop-out

x Uc

0.2 - 0.6

0.2 - 0.6

0.2 - 0.6

0.2 - 0.6

AC operated 50/60 Hz

Pick-up

VA

24

50

150

180

AC operated 50/60 Hz

Pick-up

W

19

40

95

150

AC operated 50/60 Hz

Sealing

VA

4

8

16

3.1

AC operated 50/60 Hz
DC operated 1)

Sealing
Pick-up

W
W

1.2
4.5

2.4
12

4
24

2.1
149

DC operated 1)

Sealing

W

4.5

0.5

0.5

2.1

% DF

100

100

100

100

Current heat loss (3 pole)
Current heat loss at I th
Impedance per pole
Magnet systems
Voltage tolerance
AC operated 50 Hz

Pick-up

AC operated 50/60 Hz
AC operated
DC operated 1)
DC operated 1)
Power consumption of the coil in a cold state and 1.0 x U c

Duty factor
Changeover times at 100 % Uc (recommended values)

0.8 - 1.1

Main contacts
AC operated
Closing delay

ms

15…21

16…22

12…18

28…33

Opening delay

ms

9…18

8…14

8…13

35…41

Closing delay

ms

31

47

54

35

Opening delay

ms

12

30

24

30

ms

10

DC operated 1)

Arcing time
Permissible residual current when A1 - A2 are
actuated from the electronic system (with 0 signal)

Notes

122

mA

10
1

1)

10
1

At least double-pulse bridge rectifier

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

15
1

1

1.1

Contactors
Contactor for capacitors

DILK

1
DILK12

General
Standards
Ambient temperature

DILK20

DILK25

DILK33

DILK50

-25…60
-25…40

-25…60
-25…40

-25…60
-25…40

IEC/EN 60947, VDE 0660

Open
Enclosed

°C
°C

-25…60
-25…40

-25…60
-25…40

Mounting position

30°

30°

°

180°

°

90

90

90

°

30°

Protection type

IP00

Protection against direct contact when
actuated from front (EN 50274)

Finger- and back-of-hand proof

IP00

IP00

IP00

IP00

Weight basic device
AC operated

kg

0.55

0.55

0.55

1

1

Solid

mm²

1 x (0.75 - 16)

1 x (0.75 - 16)

1 x (0.75 - 16)

1 x (2.5 - 16)

1 x (2.5 - 16)

Flexible with ferrule

mm²

1 x (0.75 - 16)

1 x (0.75 - 16)

1 x (0.75 - 16)

1 x (2.5 - 35)

1 x (2.5 - 35)

Stranded
Solid or stranded

mm²
AWG

1 x 16
18 - 16

1 x 16
18 - 6

1 x 16
18 - 6

1 x (16 - 50)
12 - 2

1 x (16 - 50)
12 - 2

mm

-

-

-

1 x (6 x 9 x 0.8)

1 x (6 x 9 x 0.8)

230 V

kvar

7.5

11

15

20

25

400 V

kvar

12.5

20

25

33.3

50

525 V

kvar

16.7

25

33.3

40

65

690 V

kvar

20

33.3

40

55

85

Terminal capacity of main cable

Flat conductor

Number of
layers x
width x
thickness

Group compensation
60 Hz

50/60 Hz
Open
230 V

Ie

A

18

29

38

50

72

400 V

Ie

A

18

29

38

50

72

525 V

Ie

A

18

29

38

50

72

690 V

Ie

A

18

29

38

50

72

230 V

Ie

A

16

26

34

45

65

400 V

Ie

A

16

26

34

45

65

525 V

Ie

A

16

26

34

45

65

690 V

Ie

A

16

26

34

45

65

x Ie

180

180

180

180

180

x 10 6

0.15

0.15

0.15

0.15

0.15

Ops/h

120

120

120

120

120

Enclosed

Making capacity (i-peak value) without
damping
Component lifespan
Maximum operating frequency

c (contacts)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

123

1.1

Contactors
Contactor for capacitors

1 DILK
DILK12

DILK20

DILK25

DILK33

DILK50

Magnet systems
Voltage tolerance
AC operated
AC operated
Power consumption of the coil in a cold state
and 1.0 x U c

Pick-up

x Uc

0.8 - 1.1

0.8 - 1.1

0.8 - 1.1

0.8 - 1.15

0.8 - 1.15

Drop-out

x Uc

0.3 - 0.6

0.3 - 0.6

0.3 - 0.6

0.3 - 0.6

0.3 - 0.6

50 Hz

Pick-up

VA

58

58

58

45

45

50 Hz
50 Hz

Sealing
Sealing

VA
W

7.6
2.3

7.6
2.3

7.6
2.3

1.5
1.5

1.5
1.5

60 Hz

Pick-up

VA

71

71

71

45

45

60 Hz
60 Hz
50/60 Hz

Sealing
Sealing
Pick-up

VA
W
VA

50/60 Hz

Sealing

VA

50/60 Hz

Sealing

W

9.3
2.8
65
59
9.6
7
2.7
2.2
100

9.3
2.8
65
59
9.6
7
2.7
2.2
100

9.3
2.8
65
59
9.6
7
2.7
2.2
100

1.5
1.5
45
45
1.5
1.5
1.5
1.5
100

1.5
1.5
45
45
1.5
1.5
1.5
1.5
100

Duty factor
Changeover times at 100 % Uc
(recommended values)
Main contacts

% DF

AC operated
Closing delay

ms

16…22

16…22

16…22

50

50

Opening delay

ms

8…14

8…14

8…14

40

40

Arcing time
Electromagnetic compatibility (EMC)

ms

10

10

10

10

10

Emitted interference

To EN 60947-1

To EN 60947-1

To EN 60947-1

To EN 60947-1

To EN 60947-1

Interference immunity
Further technical data

To EN 60947-1

To EN 60947-1

To EN 60947-1

To EN 60947-1

To EN 60947-1

M17

M25

M32

M50

M65

As per contactor

124

DIL

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Contactors
Illumination contactors

1.1

DILL

1
DILL12

General
Standards
Lifespan, mechanical
AC operated
Operating frequency, mechanical
Mechanical, AC operated
Maximum operating frequency
Electrical

DILL20

IEC/EN 60947, VDE 0660, UL, CSA
c (contacts)

x 10 6

Operations/h
Operations/h

Climatic proofing

Ambient
temperature

DILL18

Open
Enclosed
Storage

°C
°C
°C

1

1

1

60

60

60

60

60

60

Damp heat, constant, to IEC 60068-2-78;
Damp heat, cyclic, to IEC 60068-2-30
-25…60
-25…60
-25…40
-25…40
-40 - 80
-40 - 80

-25…60
-25…40
-40 - 80

Mounting position
30°

90

90

°

30°

180°

°

Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 ms

6.9

6.9

6.9

IP00

IP00

IP00

kg

0.42

0.42

0.42

U imp

V AC

Ui
Ue

V AC
V AC
A
A

8000
III/3
690
690
238
170
10000

8000
III/3
690
690
350
250
10000

8000
III/3
690
690
550
320
10000

Protection type
Weight
AC operated
Main contacts
Rated impulse withstand voltage
Overvoltage category/pollution degree
Rated insulation voltage
Rated operating voltage
Making capacity
Breaking capacity
Lifespan, electrical
Short-circuit protection rating maximum fuse
400 V
AC voltage
AC-1 operation
Conventional thermal current
at 40 °C
at 60 °C
230 V
400 V
AC-1 operation
220/230 V
400 V
Electric lamps
Filament bulbs
Mercury blended lamps
Fluorescent lamp load
Conventional reactor starter connection
Duo circuit
Electronic upstream devices
High-pressure mercury vapour lamps
Metal-halide lamps
High-pressure sodium lamps
Low-pressure sodium lamps
Maximum permissible compensation capacitance
Further technical data
As per contactor

380/400 V
c (contacts)
gG/gL 500 V

A

63

100

125

I th
I th
Ie
Ie

A
A
A
A

27
24
12
12

40
35
18
18

45
40
20
20

Ie
Ie

A
A

14
14

21
21

27
27

A
A

14
12

21
16

27
23

A
A
A
A
A
A
A
μF

20
20
12
12
12
12
7.5
470

26
26
18
18
18
18
10
470

35
35
20
20
20
20
12
470

M17

M25

M32

DIL

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

125

1.1

Contactors
Contactors up to 150 A with electronic actuation

1 DILMF
DILMF8

DILMF11

General
Mounting position

DILMF14
30°

180°

°
90

90
°

30°

DILMF17

AC voltage
AC-3 operation
Rated operational current AC -3 open,
50 – 60 Hz, 3 pole

Rated operational power

220/230 V
240 VI
380/400 V
415 V
440 V
500 V
660/690 V
220/230 V
240 V
380/400 V
415 V
440 V
500 V
660/690 V

Ie
Ie
Ie
Ie
Ie
Ie
Ie
P
P
P
P
P
P
P

A
A
A
A
A
A
A
kW
kW
kW
kW
kW
kW
kW

7
7
7
7
7
5
4
2.2
2.2
3
4
4.5
3.5
3.5

9
9
9
9
9
7
5
2.5
3
4
5.5
5.5
4.5
4.5

12
12
12
12
12
10
7
3.5
4
5.5
7
7.5
7
6.5

18
18
18
18
18
18
12
5
5.5
7.5
10
10.5
12
11

220/230 VI
240 V
380/400 V
415 V
440 V
500 V
660/690 V
220/230 V
240 V
380/400 V
415 V
440 V
500 V
660/690 V

Ie
Ie
Ie
Ie
Ie
Ie
Ie
P
P
P
P
P
P
P

A
A
A
A
A
A
A
kW
kW
kW
kW
kW
kW
kW

5
5
5
5
5
4.5
4
1
1.5
2.2
2.3
2.4
2.5
2.9

6
6
6
6
6
5
4.5
1.5
1.6
2.5
2.8
3
2.8
3.6

7
7
7
7
7
6
5
2
2.2
3
3.4
3.6
3.5
4.4

10
10
10
10
10
10
8
2.5
3
4.5
5
5.5
6
6.5

W
W

2.4
0.3

2.4
0.6

2.4
1

7.3
1.9

x Uc
x Uc
VA
VA
W
% DF
ms
ms

0.8 - 1.15
0.2 - 0.5
14
0.7
0.7
100
40
45
SEMI F47

0.8 - 1.15
0.2 - 0.5
14
0.7
0.7
100
40
45
SEMI F47

0.8 - 1.15
0.2 - 0.5
14
0.7
0.7
100
40
45
SEMI F47

0.8 - 1.15
0.2 - 0.5
14
0.7
0.7
100
40
45
SEMI F47

AC-4 operation

Rated operational current AC-4 open,
50 - 60 Hz, 3 pole

Rated operational power

Current heat loss (3 pole)
Current heat loss at Ith
Current heat loss at Ie to AC-3/400 V
Magnet systems
Voltage tolerance
AC operated
AC operated
Electronic actuation
Power consumption of
the coil in a cold state
Electronic actuation
and 1.0 x U c
Electronic actuation
Duty factor
Closing delay
Switching times
Opening delay
suitable according to
Electromagnetic compatibility (EMC)
Emitted interference
Interference immunity
Further technical data
As per contactor
Terminal type
As per contactor

126

Pick-up
Drop-out
Pick-up
Sealing
Sealing

To EN 60947-1
To EN 60947-1
DIL

M7

M9

M12

M17

DIL

M17

M17

M17

M17

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Contactors up to 150 A with electronic actuation

1
DILMF25

DILMF32

DILMF40

DILMF65

DILMF80

DILMF95

DILMF115

DILMF150

30°

180°

°
90

90
°

30°

DILMF50

25
25
25
25
25
25
15
7.5
8.5
11
14.5
15.5
17.5
14

32
32
32
32
32
32
18
10
11
15
19
20
23
17

40
40
40
40
40
40
25
12.5
13.5
18.5
24
25
28
23

50
50
50
50
50
50
32
15.5
17
22
30
32
36
30

65
65
65
65
65
65
37
20
22
30
39
41
47
35

80
80
80
80
80
80
65
25
27.5
37
48
51
58
63

95
95
95
95
95
95
80
30
4
45
57
60
70
75

115
115
115
115
115
115
93
37
40
55
70
75
85
90

150
150
150
150
150
150
100
48
52
75
91
95
110
96

13
13
13
13
13
13
10
3.5
4
6
6.5
7
8
8.5

15
15
15
15
15
15
12
4
4.5
7
7.5
8
9
10

18
18
18
18
18
18
14
5
5.5
9
9.5
10
11
12

21
21
21
21
21
21
17
6
6.5
10
11
12
13
14

25
25
25
25
25
25
20
7
7.5
12
13
14
16
17

40
40
40
40
40
40
27
12
13
20
24
25
29
26

50
50
50
50
50
50
37
16
17
26
30
32
36
35

55
55
55
55
55
55
45
17
19
28
33
35
40
43

65
65
65
65
65
65
50
20
22
33
39
41
47
48

9.6
3.8

12.1
6.1

11.3
7.2

19
11.3

28.8
19

14.6
11.5

21.8
16.2

30.4
23.8

46.1
40.5

0.8 - 1.15
0.2 - 0.5
14
0.7
0.7
100
40
45
SEMI F47

0.8 - 1.15
0.2 - 0.5
14
0.7
0.7
100
40
45
SEMI F47

0.8 - 1.15
0.2 - 0.5
45
1.5
1.5
100
50
45
SEMI F47

0.8 - 1.15
0.2 - 0.5
45
1.5
1.5
100
50
45
SEMI F47

0.8 - 1.15
0.2 - 0.5
45
1.5
1.5
100
50
45
SEMI F47

0.8 - 1.15
0.2 - 0.5
75
2
2
100
55
40
SEMI F47

0.8 - 1.15
0.2 - 0.5
75
2
2
100
55
40
SEMI F47

0.8 - 1.15
0.2 - 0.5
180
3.1
2.1
100
40
40
SEMI F47

0.8 - 1.15
0.2 - 0.5
180
3.1
2.1
100
40
40
SEMI F47

M25

M32

M40

M50

M65

M80

M95

M115

M150

M25

M32

M40

M50

M65

M80

M95

M115

M150

To EN 60947-1
To EN 60947-1

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

127

1.1

Contactors
Auxiliary contact modules

1 DILM..., DILA...

Auxiliary contact
Interlocked opposing contacts within an auxiliary
contact module (to IEC 60947-5-1 Annex L) 1)
Normally closed (not late-normally closed)
suitable as a mirror contact (to IEC/EN 60947-4-1,
Annex F)
Rated impulse withstand voltage
Overvoltage category/pollution degree

DILM7-… DILM38-…

DILAXHI(C)…(-S)

DILM32XHI(C)…(-S)

DILM150XHI…

DILM1000-XHI…
DILM820-XHI…

-

Yes

Yes

Yes

Yes

DILM7 DILM38

DILM7 DILM38

DILM7 DILM38

DILM40 DILM170

DILM40 - DILM225A
DILM250 - DILM1000

Uimp

V AC

6000
III/3

6000
III/3

6000
III/3

6000
III/3

6000
III/3

Rated insulation voltage

Ui

V AC

690

690

690

690

690

Rated operating voltage

Ue

V AC

500

500

500

500

500

Safe isolation according to EN 61140
Between coil and auxiliary contacts
Between the auxiliary contacts
Rated operational current

V AC

400

400

400

440

440

V AC

400

400

400

440

440

AC-15

DC L/R

230 V
380/415 V

Ie
Ie

A
A

4
4

4
4

4
4

4
4

4
4

500 V

1.5

Ie

A

1.5

–

1.5

1.5

15 ms 2)
24 V

Ie

A

10

10

10

10

10

60 V

Ie

A

6

6

6

6

6

110 V

Ie

A

3

3

3

3

3

220 V

Ie

A

1

1

1

1

1

3
3

24 V
60 V

A
A

2.5
1

2.5
1

2.5
1

–
–

–
–

3
3

110 V
220 V

A
A

0.5
0.25

0.5
0.25

0.5
0.25

–
–

–
–

I th
Fault
probability

A

10
16
16
< 10 -8 , < 1 one failure in 100 million operations

16

10

c (contacts)

x 10 6

1.3

1.3

1.3

1.3

A gG/gL

10
10
10
1) Not with DIL…-XHIV and DIL…-XHICV.

16

16

DC-13 (6xP)
Contacts in series:

Conventional thermal current
Control circuit reliability (at Ue = 24 V DC,
U min = 17 V, Imin = 5.4 mA)
Component lifespan
at Ue = 230 V, AC-15, 3 A

1.3

Short-circuit rating without welding
Max. fuse

Notes

128

2)

Switch-on and switch-off conditions based on DC-13, time constant as specified.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.1

Contactors
Paralleling link

P1SIL...M, DILM...-XP1

1
P1DILEM
DILM12-XP1

DILM32-XP1

DILM65-XP1

DILM150-XP1

DILM185-XP1

16
1 x (16 - 35)

16
1 x (16 - 120)

–
–

–
–

1 x (16 - 50)

1 x (16 - 120)

–

–

1 x (35 - 300)
2 x (35 - 120)
2 x (11 x 21 x 1)

–

mm

1 - 16
1 x (0.5 - 25)
2 x (0.5 - 16)
1 x (0.5 - 25)
2 x (0.5 - 16)
6 x 9 x 0.8

Tightening torque

Nm

4

4

14

14

Terminal capacity of control
circuit cable
Solid

mm²

–

–

–

–

mm²

–

–

–

–

Parallel connector
Terminal capacity
Solid
Flexible with ferrule

mm²
mm²

Stranded

mm²

Flat conductor

Number of
layers x width x
thickness

Flexible with ferrule

1 x (6 x 16 x 0.8)
2 x (20 x 32 x 0.5)
2 x (11 x 21 x 1)
6

1 x (0.75 - 4)
2 x (0.75 - 4)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)

Tools
Pozidriv screwdriver

Size

2

2

–

–

–

SW

mm

–

–

5

6

5

3 pole

I th

A

50

100

180

400

700

4 pole

I th

A

60

–

–

–

–

Internal hexagon
Conventional thermal current

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

129

1.1

Contactors
Minicontactor relay, contactor combination

Dimensions
1 Mini contactor relays
DILER-...(-C)
DILER-...-G(-C)

DILER-...(-C) + ...DILE(-C)
DILER-...-G(-C) + ...DILE(-C)
5.5

50

58

58

M4

35

83 (86)

45

52 (54)

45

DILEEM-..., DILEM-...(-C), DILEM-12-...
DILEEM-...-G, DILEM-...-G(-C), DILEM-12-...-G
c

Part no.

c

c1

DILE(E)M-...(-G)
52
DILE(E)M-...-G(-C) 54

50

58

M4

83
86

35

c1

45

Suppressor circuit

DILER-... + HDILE
DILER-...-...G + HDILE

RCDILE...
VGDILE

62.5

45

58

43

45

52

45

65,3

2DILE-... + MVDILE + ...DILE
2DILE-...-G + MVDILE + ...DILE

58

58

2DILE-... + MVDILE
2DILE-...-G + MVDILE

90

63

94

90

Star-delta contactors
SDAINLEM

108

108

61

61

Rsrotcatnocgnisreve
DIULEM

94

90

180

Parallel connector

DILER-... + TDDILE24

P1DILEM

83.5

75

~125

40

65.5

45

130

4,7

67

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

83

Contactors
Basic devices up to 170 A, contactor relay

1.1
1

Contactor with auxiliary contact module
DILM7...DILM15
DILA...
36

68

45

18

60

2 x M4

35
8.7 8.7 8.7

8.7

(5.1)

3.2
6.5

45

10.2

75
c

Part no.

c

DILM32-XHI
DILA-XHI
DILA-XHI...T

117
117
125

DILMC7...DILMC15
DILAC...
DILA-XHIC...

1.8

6.5

8.7 8.7 8.7

(5.1)

75

45

10.2

35

3.2

1.8
8.7

60

68

52.3

26.4

2 x M4

125

DILM17...DILM38
DILMC17...DILMC32
DILMF8...DILMF32

75

71

38

85

35

4.5

4.5
11

4.8

11.611.6

Clearance at side to grounded
parts: 6 mm

6.5
97.4

17.7
6.4

60.4

2 x M4

10.6

138

45

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

131

1.1

Contactors
Basic devices up to 170 A, suppressor circuit

1 Contactors
DILM40...DILM72
DILMC40...DILMC65
DILMF40...DILMF65

105

115

104

57

86.4

2 x M4

34.4

4.7

55

6.9

45
Clearance at side to grounded parts: 6 mm
114

77

132.1
147

DILM80...DILM170
DILMC80...DILMC150
DILMF80...DILMF150

156

156

170

76.5

57

4 x M6

90

82.5

111

85.5

70
142
160
175

Clearance at side to
grounded parts: 10 mm

Suppressor circuits

b
a

132

b1

DILM...XSP...

c

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Part no.

a

b

DILM12-XSP...
DILM32-XSP...
DILM95-XSP...

25
25
25

28
28
28

b1

c
32
32
32

9
9
9

Contactors
Basic devices up to 200 A

1.1

Contactor with auxiliary contact module

1

DILMP20

60

68

45

18

2 x M4

35

3.2

36

6.5

45

75
117

DILMP32

DILMP45

75

85

71

60.4

38

2 x M4

35

4.5

58

Distance at side to
grounded parts: 6 mm

6.5
97.4
138

Contactors
DILMP63

DILMP80

105

115

104

86.4

57

2 x M4

74

4.7

85

6.9

45
Distance at side to
grounded parts: 6 mm
114
132.1
147

DILMP125

DILMP160

DILMP200

156

156

170

57

4 x M6

122

82.5

133

85.5

70
142
160

Clearance at side to earthed
parts: 10 mm

175

Motor suppressor module

68

38.3

DILM12-XMSM

75
101.2

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

133

1.1

Contactors
Complete units for currents greater than 170 A

1 Complete units
DILM185A...DILM500
DILM250-S...DILM570-S
DILM1000-XHI...-SI
DILM1000-XHI11-SA

a2
a
11

b1

b

b3

b2

M6

e
a1

f

d1

c

d2

8

Part no.

a

a1

a2

b

b1

b2

b3

d1

d2

e

c

f

DILM185A
DILM225A
DILM250
DILM300A
DILM400

140
140
140
140
160

120
120
120
120
130

160
160
160
160
180

180
180
180
180
200

160
160
160
160
180

165
165
164
164
184

190
190
189
189
209

20
20
25
25
25

41
41
48
48
48

5
5
5
5
6

158
158
208
208
216

83
83
140
140
140

DILM500

160

130

180

200

180

189

219

38

57

6

216

140

DILM570

160

130

180

200

180

189

219

38

57

6

216

140

DILM580...DILM1000
f

215

b3

b2

232

M6

165

80

e

d1
250

140
232

270

DILM820-XHI...-SI
DILM820-XHI11-SA

134

Part no.
DILM580
DILM650
DILM750
DILM820
DILM1000

b2
256
256
256
256
256

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

b3
296
296
296
296
296

d1
45
45
45
45
45

e
6
6
6
6
10

f
13.5
13.5
13.5
13.5
13.5

Contactors
Contactors greater than 1000 A

1.1

AC -1 contactors greater than 1000 A

1

DILH1400

215

232

342

256

308

35

210

M6

165
14

60
100

130

35

10

100

232

260

DILM1600
DILH2000
DILH2200

270

300

392

272

352

96

210

M6

14

430

40

40

80

80

150
172.5

150

10
252

125
172.5

515

DILH2600

270

300

422

206

160

210

(342)

136

M6

430

14

40

40

80

80

150
172.5

150

10
252

125
172.5

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

135

1.1

Contactors
Capacitor contactors, lamp contactors, contactor monitoring devices, SWD contactor modules

1 Contactor for capacitors
DILK…

b

b1

Part no.
DILK12
DILK20
DILK25
DILK33
DILK50

d
a1

a

c

a
45
45
45
55
55

b
135
135
135
190
190

c
138
138
138
147
147

a1
35
35
35
45
45

b1
75
75
75
105
105

d
2 x M4
2 x M4
2 x M4
2 x M4
2 x M4

Illumination contactors
DILL…

75

85

38

60.4

2 x M4

35
4.5

4.5

4.8

6.5

17.7

Clearance at side to grounded parts: 6 mm
97.4

11.6 11.6 10.6

(6.4)

45

138

Contactor monitoring devices
CMD(...)
103
98

78

82.5

22.5

SWD contactor modules

38

DIL-SWD-32-...

45

53.1
72.3

136

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Contactors
Contactor combinations

1.1

Star-delta contactors

1

b

SDAINLM12...SDAINLM115

a

Part no.
SDAINLM12...22
SDAINLM30...55
SDAINLM70...115

c

a
158
158
188

b
68
85
115

c
117
138
147

299
144

144

314

SDAINLM140...SDAINLM260

183

M6

308

Reversing contactors

b

DIULM7...DIULM65

a

c

Part no.
DIULM7/21...12/21
DIULM17/21...32/21
DIULM40/11...65/11

a
90
90
110

b
68
85
115

c
117
138
147

176

314

299

DIULM80…DIULM150

M6

183

196

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

137

1.1

Contactors
Accessories

1 Three-phase commoning links
DILM12-XDSB...

13.1

18.1

Part no.
DILM12-XDSB0/3

a

12.5

a
112
157

DILM12-XDSB0/4
DILM12-XDSB0/5

202

Amplifier module

DILM…XTE

ETS4- VS3

78

82.5

70

45

103
98

22.5

25

38

Electronic timer modules

Wiring set for motor feeder plug
DILM12- XMCP/T

30

45

45

20

45

37

20

DILM12- XMCE

80

6

25

25

50

30

27

45

20

30

37

DILM12-XMCP/E

6

25

80

45

50

27

138

12

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

12

1.1

Contactors

Contactors with terminal shrouds

1

DILM250...DILM1000 + DILM...-XHB

DILM250 + Z5-.../FF250

a

523

328

b

110

150

34

for part no.

a

b

DILM250, DILM300A
DILM400
DILM500
DILM580...1000

150
150
174
236

384
404
426
506

~144

DILM185A...DILM225A + DILM225A-XHB

Contactor with star-point bridge and terminal shroud

for part no.

a

b

DILM185...250
DILM300...400
DILM500

150
150
176

127
137
146

b

325

DILM...XS1

a
124
140

Mechanical interlock
DILM500- XMV

DILM820- XMV
a

515

a
15

430

20

270
300

for part no.
DILM185...500

9

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

139

1

Overload relay
Motor protection is a central task of electrical equipment for machinery. From
cost-effective bimetal solutions to demanding full motor protection with cross-linkage we offer the right solution for each application.

ATEX

Bimetal relay - overload relay up to 630 A
• Direct mounting on contactor saves mounting time.
• ATEX approval for the protection of EEx e motors up to 250 A.
• Comprehensive motor protection through phase failure sensitivity.
• Integrated test pushbutton facilitates high safety
Page 6.
ZEB electronic overload relay - overload relay up to 1500 A
• ATEX approval for protection of EEx e motors up to 1500 A.
• Adjustable tripping classes.
• Phase failure and unbalance protection.
• Optional earth fault detection.
• Additional current setting range (5:1)
Page 14.
EMT6 thermistor overload relay for machine protection
• Overload protection through direct evaluation of winding temperature.
• Quick detection of operating state through LED display.
• Suitable for overload monitoring of motors in EEx e range.
• Wide range power supply reduces amount of types Page 19.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Overload relays
Contents

Technical overview
Bimetal relay ZE, ZB, Z5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overload relay ZW7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electronic overload relays ZEB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EMT6 thermistor overload relay for machine protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
2
4
4

Ordering
Bimetal relays for mini-contactor relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bimetal relays up to 150 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bimetal relay greater than 150 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overload relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bimetal relay accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ZEB electronic overload relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6
8
12
12
21
14

1

Ordering
EMT6 thermistor overload relay for machine protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Engineering
EMT6 thermistor overload relay for machine protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Selection criteria ZE, ZB, Z5, ZW7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Characteristic curve ZB, Z5, ZW7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UL/CSA short-circuit strength ZE, ZB, Z5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20
23
23
24

Technical data
Bimetal relay for mini-contactor relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bimetal relays up to 150A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overload relays greater than 150 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overload relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ZEB electronic overload relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EMT6 thermistor overload relay for machine protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

25
25
26
26
28
29

Dimensions
Bimetal relays for mini-contactor relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bimetal relays up to 150A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bimetal relays greater than 150 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overload relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ZEB electronic overload relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EMT6 thermistor overload relay for machine protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

30
30
32
32
33
35

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1

1.2
1

Overload relays
Overload relays, CT-operated overload relays

Technical overview
Overload relays, CT-operated overload relays
Electronic overload relays, thermistor overload relay for machine protection

Setting ranges (A)
(note max. current of the contactor)

DILEM

DILM7 DILM12
DILM9 DILM15

DILM17 DILM32
DILM25 DILM38

Overload relays
ZE
0.1-12

ZB12
0.1-16

ZB32
0.1-38

ZB65
6-75

ZB150
35-175

Z5-.../FF225A
70-250

Z5-.../FF250
50-300

Current transformer-operated overload relay
ZW7-...
42-630

2

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

DILM40 DILM65
DILM50 DILM72

DILM80 DILM150
DILM95 DILM170
DILM115

Overload relays
Overload relays, CT-operated overload relays

1.2
1

DILM185A
DILM225A

DILM250
DILM300

DILM400 DILM580
DILM500

DILM650

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

3

1.2

Overload relays
Electronic overload relays, thermistor overload relay for machine protection

1 Electronic overload relays, thermistor overload relay for machine protection

Setting ranges (A)
(note max. current of the contactor)

DILEM

DILM7 DILM12
DILM9 DILM15

DILM17 DILM32
DILM25 DILM38

Electronic overload relays
ZEB12
0.33-20

ZEB32
0.33-45

ZEB65
9-100

ZEB150
20-100

ZEB32-5-(GF)/KK combined with
ZEB-XCT300
60-300
ZEB-XCT600
120-600
ZEB-XCT1000
200-1000
ZEB-XCT1500
300-1500
Thermistor overload relay for machine protection
EMT6((DB)K)

4

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

DILM40 DILM65
DILM50 DILM72

DILM80 DILM150
DILM95 DILM170
DILM115

Overload relays
Electronic overload relays, thermistor overload relay for machine protection

1.2
1

DILM185A
DILM225A

DILM250
DILM300

DILM400 DILM580
DILM500 DILM650

DILM750 DILM820

DILM1000

DILM1600

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

5

1.2
1

Overload relays
Bimetal relays for mini-contactor relays

Ordering
ZE overload relays for mini contactor relays
•
•
•
•
•

Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102
Test/off pushbutton
Reset pushbutton manual/auto
Trip-free release
Direct mounting

Setting range of
overload
releases

Circuit symbol

Auxiliary contact

For use with

N/O = normally open contact
NC = normally closed contact
Ir

Type “1”
coordination
gG/gL

Type “2”
coordination
gG/gL

A

A

A

20

0.5

20

1

0.1 – 0.16

1 N/O

1 NC

1 N/O

1 NC

0.24 – 0.4

1 N/O

1 NC

20

2

0.4 – 0.6

1 N/O

1 NC

20

2

0.6 – 1

1 N/O

1 NC

20

4

1 – 1.6

1 N/O

1 NC

20

6

1.6 – 2.4

1 N/O

1 NC

20

6

2.4 – 4

1 N/O

1 NC

20

10

4–6

1 N/O

1 NC

20

10

6–9

1 N/O

1 NC

20

10

9 – 12

1 N/O

1 NC

20

10

0.16 – 0.24

97 95

2

4

6

98 96

DILEM
DIULEM/21/MV
SDAINLEM

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
Max. Voltage Rating
Degree of Protection
See also

6

Short-circuit protection

UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking
E29184
NKCR
12528
3211-03
UL Listed, CSA certified
Branch circuits
600 V AC
IEC: IP20, UL/CSA Type: Page 24

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Overload relays
Bimetal relays for mini-contactor relays

1.2
1

Part no.
Article no.

ZE-0.16
014263
ZE-0.24
014285
ZE-0.4
014300
ZE-0.6
014333
ZE-1.0
014376
ZE-1.6
014432
ZE-2.4
014479
ZE-4
014518
ZE-6
014565
ZE-9
014708
ZE-12
014752

Price
See price
list

Std. pack

Notes

1 Off

Overload release: tripping class 10 A
Short-circuit protection: With direct mounting,
observe the maximum permissible fuse of the
contactor.

With side-by-side mounting, there must be a minimum clearance
of 5 mm between overload relays.

Suitable for protection of EEx e motors

1

II (2) GD
PTB 01 ATEX 3331
Observe manual AWB2300-1425D/GB.

1 Contactor
Chapter 1.1
Accessories
Page 21
Manual
Page 21

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

7

1.2

Overload relays
Overload relays up to 150A

ZB12, ZB32

1

Setting range of
overload releases

ZB12 overload relay

Circuit symbol

For use with

N/O = normally open contact
NC = normally closed contact

Contactors

Short-circuit protection

Ir

Type “1”
coordination
gG/gL

Type “2”
coordination
gG/gL

A

A

A

–

25

0.5

–

25

1

–

25

2

–

25

4

0.1 – 0.16

1 NC

1 N/O

1 NC

0.24 – 0.4

1 N/O

1 NC

0.4 – 0.6

1 N/O

1 NC

0.6 – 1

1 N/O

1 NC

–

25

4

1 – 1.6

1 N/O

1 NC

–

25

6

1.6 – 2.4

1 N/O

1 NC

–

25

10

2.4 – 4

1 N/O

1 NC

D S 7- 34…S X 004…

25

16

4–6

1 N/O

1 NC

D S 7- 34…S X 005…

25

20

6 – 10

1 N/O

1 NC

50

25

9 – 12

1 N/O

1 NC

DS7-34…SX007…
DS7-34…SX009…
DS7-34…SX012…

50

25

12 – 16

1 N/O

1 NC

–

50

25

1 N/O

1 NC

–

25

0.5

1 N/O

1 NC

–

25

1

0.24 – 0.4

1 N/O

1 NC

–

25

2

0.4 – 0.6

1 N/O

1 NC

–

25

4

0.6 – 1

1 N/O

1 NC

–

25

4

1 – 1.6

1 N/O

1 NC

–

25

6

1.6 – 2.4

1 N/O

1 NC

–

25

10

2.4 – 4

1 N/O

1 NC

–

25

16

4–6

1 N/O

1 NC

–

25

20

6 – 10

1 N/O

1 NC

–

50

25

10 – 16

1 N/O

1 NC

DS7-34...SX016...

63

35

16 – 24

1 N/O

1 NC

DS7-34...SX024...

100

35

24 – 32

1 N/O

1 NC

DS7-34...SX032...

125

63

32 – 38

1 N/O

1 NC

–

125

63

2

4

6

0.1 – 0.16

98 96 A2 14/
22

97 95

0.16 – 0.24
2

4

6

98 96 14/
22

DILM7, DILM9,
DILM12, DILM15,
DIULM7, DIULM9,
DIULM12,
SDAINLM12,
SDAINLM16,
SDAINLM22

Soft starters

1 N/O

97 95

0.16 – 0.24

ZB32 overload relay

Auxiliary contact

DILM17, DILM25,
DILM32,
DILM38,
DILMF8,
DILMF11,
DILMF14,
DILMF17,
DILMF25,
DILMF32,
DIULM17,
DIULM25,
DIULM32,
SDAINLM30,
SDAINLM45,
SDAINLM55

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.

8

UL 508; CSA-C22.2 No.14; IEC/EN
60947-4-1; CE marking
E29184
NKCR
12528
3211-03

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

NA Certification
Suitable for
Max. Voltage Rating
Degree of Protection
See also

UL Listed, CSA certified
Branch circuits
600 V AC
IEC: IP20, UL/CSA Type: Page 24

Overload relays
Overload relays up to 150A

1.2
1

Part no.
Article no.

ZB12-0,16
278431
ZB12-0,24
278432
ZB12-0,4
278433
ZB12-0,6
278434
ZB12-1
278435
ZB12-1,6
278436
ZB12-2,4
278437
ZB12-4
278438
ZB12-6
278439
ZB12-10
278440
ZB12-12
278441
ZB12-16
290168
ZB32-0,16
278442
ZB32-0,24
278443
ZB32-0,4
278444
ZB32-0,6
278445
ZB32-1
278446
ZB32-1,6
278447
ZB32-2,4
278448
ZB32-4
278449
ZB32-6
278450
ZB32-10
278451
ZB32-16
278452
ZB32-24
278453
ZB32-32
278454
ZB32-38
112474

Price
See price
list

Std. pack

Notes

1 Off

Overload release: tripping class 10 A
Short-circuit protection: With direct mounting,
observe the maximum permissible fuse of the
contactor.

Fitted directly to the contactor
1

Suitable for protection of EEx e motors.
II (2) GD
PTB 04 ATEX 3022
Observe manual AWB2300-1527D/GB.
• Phase failure sensitivity to IEC/EN 60947, VDE 0660
Part 102
• Test/off pushbutton
• Reset pushbutton manual/auto
• Trip-free release
• Direct mounting

1 Off

Overload release: tripping class 10 A
Short-circuit protection: With direct mounting,
observe the maximum permissible fuse of the
contactor.

1 Contactor
Chapter 1.1
Accessories
Page 21
Manual
Page 21

Fitted directly to the contactor

Separate mounting

1

1

Suitable for protection of EEx e motors.
II (2) GD
PTB 04 ATEX 3022
Observe manual AWB2300-1527D/GB.
• Phase failure sensitivity to IEC/EN 60947, VDE 0660
Part 102
• Test/off pushbutton
• Reset pushbutton manual/auto
• Trip-free release
• Direct mounting

2

1 Contactor
Chapter 1.1
2 Base
Page 21
Manual
Page 21

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

9

1.2

Overload relays
Overload relays up to 150A

ZB65, ZB150

1

Setting range of
overload
releases

Circuit symbol

Auxiliary contact

For use with

N/O = normally open contact
NC = normally closed contact
Ir
A

ZB65 overload relay
• Phase failure sensitivity to IEC/EN
60947, VDE 0660 Part 102
• Test/off pushbutton
• Reset pushbutton manual/auto
• Trip-free release
• Direct mounting

ZB150 overload relay
• Phase failure sensitivity to IEC/EN
60947, VDE 0660 Part 102
• Test/off pushbutton
• Reset pushbutton manual/auto
• Trip-free release
• Direct mounting

ZB150 overload relay
• Phase failure sensitivity to IEC/EN
60947, VDE 0660 Part 102
• Test/off pushbutton
• Reset pushbutton manual/auto
• Trip-free release
• Separate mounting

6 – 10

DILM40, DILM50,
DILM65,
DILM72,
DILMF40,
DILMF50,
DILMF65,
DIULM40, DIULM50,
DIULM65,
SDAINLM70,
SDAINLM90,
SDAINLM115

Type “1”
coordination
gG/gL
A

Type “2”
coordination
gG/gL
A

50

25

63

35

63

50

125

63

160

80

1 N/O

1 NC

1 N/O

1 NC

16 – 24

1 N/O

1 NC

24 – 40

1 N/O

1 NC

40 – 57

1 N/O

1 NC

50 – 65

1 N/O

1 NC

160

100

65 – 75

1 N/O

1 NC

250

160

1 N/O

1 NC

160

125

1 N/O

1 NC

250

160

70 – 100

1 N/O

1 NC

315

200

95 – 125

1 N/O

1 NC

315

250

120 – 150

1 N/O

1 NC

315

250

145 – 175

1 N/O

1 NC

DILM80, DILM95,
DILM115, DILM150,
DILM170
DILMF80,
DILMF95,
DILMF115,
DILMF150,
DIULM80, DIULM95,
DIULM115, DIULM150,
SDAINLM140,
SDAINLM165,
SDAINLM200,
SDAINLM260

315

250

1 N/O

1 NC

160

125

1 N/O

1 NC

250

160

70 – 100

1 N/O

1 NC

315

200

95 – 125

1 N/O

1 NC

315

250

120 – 150

1 N/O

1 NC

315

250

145 – 175

1 N/O

1 NC

DILM80, DILM95,
DILM115, DILM150,
DILM170
DILMF80,
DILMF95,
DILMF115,
DILMF150,
DIULM80, DIULM95,
DIULM115, DIULM150,
SDAINLM140,
SDAINLM165,
SDAINLM200,
SDAINLM260

400

315

10 – 16

97 95

2

4

6

35 – 50

98 96

97 95

50 – 70
2

4

6

35 – 50
50 – 70

98 96

97 95

2

4

6

98 96

Information relevant for export to North America
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
Max. Voltage Rating
Degree of Protection
See also

10

Short-circuit protection

UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking
E29184
NKCR
12528
3211-03
UL Listed, CSA certified
Branch circuits
600 V AC
IEC: IP00, UL/CSA Type: Page 24

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Overload relays
Overload relays up to 150A

1.2
1

Part no.
Article no.

ZB65-10
278455
ZB65-16
278456
ZB65-24
278457
ZB65-40
278458
ZB65-57
278459
ZB65-65
278460
ZB65-75
108792
ZB150-50
278462
ZB150-70
278463
ZB150-100
278464
ZB150-125
278465
ZB150-150
278466
ZB150-175
107316

ZB150-50/KK
278468
ZB150-70/KK
278469
ZB150-100/KK
278470
ZB150-125/KK
278471
ZB150-150/KK
278472
ZB150-175/KK
107317

Price
See price
list

Std. pack

Notes

1 Off

Overload release: tripping class 10 A
Short-circuit protection: With direct mounting,
observe the maximum permissible fuse of the
contactor.

Fitted directly to the contactor

Separate mounting

Suitable for protection of EExe motors.
1

II (2) GD
PTB 04 ATEX 3022

1

Observe manual AWB2300-1545D/GB.

1 Off

Overload release: tripping class 10 A
Short-circuit protection: With direct mounting,
observe the maximum permissible fuse of the
contactor.

2

Suitable for protection of EEx e motors.
II (2) GD
PTB 04 ATEX 3022
Observe manual AWB2300-1545D/GB.

1 Off

Overload release: tripping class 10 A
Short-circuit protection: With direct mounting,
observe the maximum permissible fuse of the
contactor.

1 Contactor
Chapter 1.1
2 Base
Page 21
Manual
Page 21

Suitable for protection of EEx e motors.
II (2) GD
PTB 04 ATEX 3022
Observe manual AWB2300-1545D/GB.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

11

1.2

Overload relays
Overload relays greater than 150 A, CT-operated overload relays

Z5, ZW7

1

Setting range of
overload releases

Circuit symbol

Auxiliary
contacts

For use with

N/O = normally open
contact
NC = normally closed
contact

Short-circuit protection

Type “1”
coordination
gG/gL

Type “2”
coordination
gG/gL

A

A

250
250
315
315

160
160
200
200

Ir
A

Z5 overload relays greater than 150A
• Phase failure sensitivity to IEC/EN
60947, VDE 0660 Part 102
• Test/off pushbutton
• Reset pushbutton manual/auto
• Trip-free release
Direct mounting
Separate mounting

Z5 overload relays greater than 150A
• Phase failure sensitivity to IEC/EN
60947, VDE 0660 Part 102
• Test/off pushbutton
• Reset pushbutton manual/auto
• Trip-free release
Direct mounting
Separate mounting

ZW7 current transformer-operated
overload relays
• Test/off button
• Reset pushbutton manual/auto
• Trip-free release
• Protection with heavy starting duty
Separate mounting

12

50 – 70

1 N/O

1 NC

1 N/O

1 NC

95 – 125

1 N/O

1 NC

315
315

250
250

120 – 160

1 N/O

1 NC

400
400

250
250

160 – 220

1 N/O

1 NC

400
500

315
400

200 – 250

1 N/O

1 NC

400
500

315
400

70 – 100

1 N/O

1 NC

250
250

160
160

70 – 100

1 N/O

1 NC

95 – 125

1 N/O

1 NC

315
315
315
315

200
200
250
250

120 – 160

1 N/O

1 NC

400
400

250
250

160 – 220

1 N/O

1 NC

200 – 250

1 N/O

1 NC

200 – 300

1 N/O

1 NC

DILM300A

400
500
400
500
500
500

315
400
315
400
400
400

1 N/O

1 NC

–

–

–

1 N/O

1 NC

–

–

–

1 N/O

1 NC

–

–

–

110 – 160

1 N/O

1 NC

–

–

–

160 – 240

1 N/O

1 NC

–

–

–

190 – 290

1 N/O

1 NC

–

–

–

270 – 400

1 N/O

1 NC

–

–

–

360 – 540

1 N/O

1 NC

–

–

–

420 – 630

1 N/O

1 NC

–

–

–

1

3

5

97 95

2

4

6

98 96

70 – 100

42 – 63

DILM185A
DILM225A

DILM250A

97 95

60 – 90
85 – 125

98 96

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Overload relays
Overload relays greater than 150 A, CT-operated overload relays

1.2
1

Part no.
Article no.

Z5-70/FF225A
139572
Z5-100/FF225A
139573
Z5-125/FF225A
139574
Z5-160/FF225A
139575

Price
See price
list

Std. pack

Notes

Information relevant for export to North America

1 Off

Overload release:
tripping class 10 A
Short-circuit protection: With direct mounting,
observe the maximum permissible fuse of the
contactor.

Product Standards

Z5-…/FF225A for protecting
EEx electric motors in preparation.

NA Certification
Suitable for
Max. Voltage Rating
Degree of Protection
See also

Fitted directly to the contactor

Z5-220/FF225A
139576
Z5-250/FF225A
139577

1

Z5-70/FF250
210070

Product Standards

Z5-100/FF250
210071
Z5-125/FF250
210072
Z5-160/FF250
210073

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
Max. Voltage Rating
Degree of Protection
See also

1 Contactor
Accessories

Z5-220/FF250
210074

Chapter 1.1
Page 22

Z5-250/FF250
210075
Z5-300/FF250
139578

Product Standards
NA Certification
Suitable for
Max. Voltage Rating
Degree of Protection

ZW7-63
000245
ZW7-90
002618

UL 508; CSA-C22.2 No.14;
IEC/EN 60947-4-1; CE marking
Request filed for UL and CSA
Branch circuits
600 V AC
IEC: IP00, UL/CSA Type: Page 24

1 Off

ZW7-125
004991
ZW7-160
007364
ZW7-240
009737

The main current characteristic values are defined
by the main current wiring being used.
Adjustment for smaller rated motor currents
Page 23

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
Max. Voltage Rating
Degree of Protection

UL 508; CSA-C22.2 No.14;
IEC/EN 60947-4-1; CE marking
E29184
NKCR
12528
3211-03
UL Listed, CSA certified
Branch circuits
600 V AC
IEC: IP00, UL/CSA Type: Page 24

UL 508; CSA-C22.2 No.14;
IEC/EN 60947-4-1; CE marking
Request filed for UL and CSA
Branch circuits
600 V AC
IEC: IP00, UL/CSA Type: UL 508; CSA-C22.2 No.14;
IEC/EN 60947-4-1; CE marking
E29184
NKCR
12528
3211-03
UL Listed, CSA certified
Branch circuits
600 V AC
IEC: IP00, UL/CSA Type: -

ZW7-290
052448
ZW7-400
045329
ZW7-540
047702
ZW7-630
050075

1 O ff

–

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

13

1.2

Electronic overload relays to 1500 A
Basic devices

ZEB12, ZEB32

1

Ground fault detection

ZEB12 electronic overload relay
• Phase-failure sensitivity
• Test/off pushbutton
• Reset button
• Manual/Auto reset selectable
• Protection with heavy starting
duty (Class 5-30)
Direct mounting

ZEB32 electronic overload relay
• Phase-failure sensitivity
• Test/off pushbutton
• Reset button
• Manual/Auto reset selectable
• Protection with heavy starting
duty (Class 5-30)
Direct mounting

ZEB32 electronic overload relay
• Phase-failure sensitivity
• Test/off pushbutton
• Reset button
• Manual/Auto reset selectable
• Protection with heavy starting
duty (Class 5-30)
Separate mounting

Setting range
of overload releases
Ir
A

Without

0.33 – 1.65

Without

1–5

Circuit symbol

For use with

N/O = normally open contact
NC = normally closed contact

97 95

2

4

6

1 N/O

1 NC

1 N/O

1 NC

98 96

Without

4 – 20

1 N/O

1 NC

With

0.33 – 1.65

1 N/O

1 NC

With

1–5

1 N/O

1 NC

With

4 – 20

1 N/O

1 NC

Without

0.33 – 1.65

1 N/O

1 NC

Without

1–5

1 N/O

1 NC

Without

4 – 20

1 N/O

1 NC

Without

9 – 45

1 N/O

1 NC

With

0.33 – 1.65

1 N/O

1 NC

With

1–5

1 N/O

1 NC

With

4 – 20

1 N/O

1 NC

With

9 – 45

1 N/O

1 NC

Without

0.33 – 1.65

1 N/O

1 NC

Without

1–5

1 N/O

1 NC

Without

4 – 20

1 N/O

1 NC

Without

9 – 45

1 N/O

1 NC

With

0.33 – 1.65

1 N/O

1 NC

With

1–5

1 N/O

1 NC

With

4 – 20

1 N/O

1 NC

With

9 – 45

1 N/O

1 NC

97 95

2

4

6

98 96

1

3

5

97 95

2

4

6

98 96

Information relevant for export to North America
Product Standards
NA Certification
Suitable for
Max. Voltage Rating
Degree of Protection

14

Auxiliary contact

UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking
Request filed for UL and CSA
Branch circuits
600 V AC
IEC: IP20, UL/CSA Type: -

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

DILM7
DILM9
DILM12
DILM15
DIULM7
DIULM9
DIULM12
SDAINLM12
SDAINLM16
SDAINLM22

DILM17
DILM25
DILM32
DILM38
DIULM17
DIULM25
DIULM32
SDAINLM30
SDAINLM45
SDAINLM55

DILM17
DILM25
DILM32
DILM38
DIULM17
DIULM25
DIULM32
SDAINLM30
SDAINLM45
SDAINLM55

Electronic overload relays to 1500 A
Basic devices

1.2
1

Part no.
Article no.

ZEB12-1,65
136480
ZEB12-5
136481

Price
See price
list

Std. pack

Notes

1 Off

Suitable for protection of EEx e motors.

Fitted directly to the contactor

II (2) GD
PTB ATEX starting 08/2010

ZEB12-20
136482
ZEB12-1,65-GF
136483

1

Observe manual AWB2320-1633D/GB.
Switchgear and cable dimensioning
according to CLASS
Page 18

ZEB12-5-GF
136484
ZEB12-20-GF
136485

1 Contactor
Accessories
ZEB32-1.65
136486

1 Off

Suitable for protection of EEx e motors.

ZEB32-5
136487

II (2) GD
PTB ATEX starting 08/2010

ZEB32-20
136488
ZEB32-45
136489
ZEB32-1,65-GF
136490

Observe manual AWB2320-1633D/GB.

Chapter 1.1
Page 18

Fitted directly to the contactor
1

Switchgear and cable dimensioning
according to CLASS
Page 18

ZEB32-5-GF
136491
ZEB32-20-GF
136492
ZEB32-45-GF
136493
ZEB32-1,65/KK
136494
ZEB32-5/KK
136495
ZEB32-20/KK
136496
ZEB32-45/KK
136497
ZEB32-1,65-GF/KK
136498
ZEB32-5-GF/KK
136499
ZEB32-20-GF/KK
136500

1 Off

Suitable for protection of EEx e motors.
1 Contactor
Accessories

II (2) GD
PTB ATEX starting 08/2010

Chapter 1.1
Page 18

Observe manual AWB2320-1633D/GB.
Switchgear and cable dimensioning
according to CLASS
Page 18

ZEB32-45-GF/KK
136501

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

15

1.2

Electronic overload relays to 1500 A
Basic devices

ZEB65, ZEB150

1

Ground fault detection

Setting range
of overload releases
Ir
A

9 – 45

With

9 – 45

Without

Auxiliary contact

For use with

N/O = normally open contact
NC = normally closed contact

1 N/O

1 NC

1 N/O

1 NC

20 – 100

1 N/O

1 NC

With

20 – 100

1 N/O

1 NC

ZEB150 electronic overload relay
• Phase-failure sensitivity
• Test/off pushbutton
• Reset button
• Manual/Auto reset selectable
• Protection with heavy starting
duty (Class 5-30)
Direct mounting

Without

20 – 100

1 N/O

1 NC

With

20 – 100

1 N/O

1 NC

ZEB150 electronic overload relay
• Phase-failure sensitivity
• Test/off pushbutton
• Reset button
• Manual/Auto reset selectable
• Protection with heavy starting
duty (Class 5-30)
Separate mounting

Without

20 – 100

1 N/O

1 NC

With

20 – 100

1 N/O

1 NC

ZEB65 electronic overload relay
• Phase-failure sensitivity
• Test/off pushbutton
• Reset button
• Manual/Auto reset selectable
• Protection with heavy starting
duty (Class 5-30)
Direct mounting

Without

Circuit symbol

97 95

2

4

6

98 96

97 95

2

4

6

98 96

1

3

5

97 95

2

4

6

98 96

Information relevant for export to North America
Product Standards
NA Certification
Suitable for
Max. Voltage Rating
Degree of Protection

16

UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking
Request filed for UL and CSA
Branch circuits
600 V AC
IEC: IP20, UL/CSA Type: -

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

DILM40
DILM50
DILM65
DILM72
DIULM40
DIULM50
DIULM65
SDAINLM70
SDAINLM90
SDAINLM115

DILM80
DILM95
DILM115
DILM150
DIULM80
DIULM95
DIULM115
DIULM150
SDAINLM140
SDAINLM165
SDAINLM200
SDAINLM260

DILM80
DILM95
DILM115
DILM150
DIULM80
DIULM95
DIULM115
DIULM150
SDAINLM140
SDAINLM165
SDAINLM200
SDAINLM260

Electronic overload relays to 1500 A
Basic devices

1.2
1

Part no.
Article no.

ZEB65-45
136502
ZEB65-45-GF
136503

Price
See price
list

Std. pack

Notes

1 Off

Suitable for protection of EEx e motors.

Fitted directly to the contactor

II (2) GD
PTB ATEX starting 08/2010

ZEB65-100
136504
ZEB65-100-GF
136505

1

Observe manual AWB2320-1633D/GB.
Switchgear and cable dimensioning
according to CLASS
Page 18

1 Contactor
Accessories
ZEB150-100
136506

1 Off

Suitable for protection of EEx e motors.

Chapter 1.1
Page 18

Fitted directly to the contactor

II (2) GD
PTB ATEX starting 08/2010

ZEB150-100-GF
136507

1

Observe manual AWB2320-1633D/GB.
Switchgear and cable dimensioning
according to CLASS
Page 18

ZEB150-100/KK
136508
ZEB150-100-GF/KK
136509

1 Off

Suitable for protection of EEx e motors.
II (2) GD
PTB ATEX starting 08/2010
Observe manual AWB2320-1633D/GB.

1 Contactor
Accessories

Chapter 1.1
Page 18

Switchgear and cable dimensioning
according to CLASS
Page 18

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

17

1.2

Electronic overload relays to 1500 A
Accessories

1 ZEB-XCT…
Setting range of
overload releases

Language

Can be used with

Part no.
Article no.

Price
See price
list

Std. pack

Ir
A
Current sensors
60 – 300

–

ZEB32-5-GF/KK
ZEB32-5/KK

ZEB-XCT3001)
136511

1off

120 – 600

–

ZEB32-5-GF/KK
ZEB32-5/KK

ZEB-XCT6001)
136512

1off

200 – 1000

–

ZEB32-5-GF/KK
ZEB32-5/KK

ZEB-XCT10001)
136517

1off

300 – 1500

–

ZEB-XCT15001)
136513

1off

–

–

–

ZEB-XSC2)
136514

1 off

–

–

–

ZEB-XRB2)
136515

1 off

–

Deutsch
English

ZEB12
ZEB32
ZEB65
ZEB150

AWB2320-1633DE/EN
136516

1 off

Sealable shroud
Cover to prevent adjustment of motor current (tamper-proof)

Reset adapter
Cover to prevent adjustment of motor current (tamper-proof)

Documentation
ZEB electronic overload relay
Overload monitoring of EEx e motors

1)

2)

Information relevant for export to North America

Information relevant for export to North America

Product Standards

Product Standards

NA Certification
Suitable for
Max. Voltage Rating
Degree of Protection

UL 508; CSA-C22.2 No.14;
IEC/EN 60947-4-1; CE marking
Request filed for UL and CSA
Branch circuits
600 V AC
IEC: IP00, UL/CSA Type: -

NA Certification
Max. Voltage Rating
Degree of Protection

UL 508; CSA-C22.2 No.14;
IEC/EN 60947-4-1; CE marking
Request filed for UL and CSA
600 V AC
IEC: IP20, UL/CSA Type: -

Switchgear and cable sizing corresponding to the respective starting inertia (CLASS) for ZEB
Switchgear is designed according to "CLASS 10" requirements for both normal and overload operation conditions. In order for the switchgear
(circuit-breaker and contactor) and the cables not to be overloaded with long tripping times, they must be overdimensioned accordingly. The rated
operational current, Ie, for switchgear and cables can be calculated with the following current factor taking the tripping class into account:
Trippling class

Class 5

Class 10

Class 15

Class 20

Class 25

Class 30

Class 35

Class 40

Current factor of
rated operational
current Ie

1.00

1.00

1.22

1.41

1.58

1.73

1.89

2.00

18

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.2

Overload relays for machine protection
Basic devices, accessories

Ordering

1

EMT6
Function

Rated operational current

Conventional
thermal
AC-15 AC-14 current
240 V 400 V

Rated control
voltage

Part no.
Article no.

Ie

Ie

I th

Us

A

A

A

V

6

24 - 240 V 50/60 Hz, EMT61) 2)
066166
24 - 240 V DC
230 V 50/60 Hz
EMT6(230V)1) 2)
066400

Price
See price
list

Std. pack

Notes

EMT6 thermistor machine protection overload relays
Without automatic reset
Mains and fault LED display

3

3

Without automatic reset
Mains and fault LED display
Tripped in the event of a short-circuit in
the sensor-cable

3

Selector switch with/without automatic
reset
For manual or remote resetting
Test button
Mains and fault LED display

3

Selector switch with/without automatic
reset
For manual or remote resetting
Test button
Mains and fault LED display
Trip with short-circuit in the sensor cable

3

3

6

24 - 240 V 50/60 Hz, EMT6-KDB 2)
24 - 240 V DC
269471

All-in-one device
Selector switch with/without automatic
reset
Trip with short-circuit in the sensor cable
Zero-voltage safe
For manual or remote resetting
Test button
Short-circuit detection and retention can
be deactivated
Mains and fault LED display

3

3

6

24 - 240 V 50/60 Hz, EMT6-DBK 2)
24 - 240 V DC
066168

3

3

1 off
II (2) G
II (2) GD only
for EMT6-K

24 - 240 V 50/60 Hz, EMT6-K 2)
24 - 240 V DC
269470

6

PTB 02 ATEX 3162
Observe the manual
AWB 2327-1446
Page 19
Can be snap fitted
on a top-hat rail to
IEC/EN 60715.
Device clearance ̱
3 mm.

24 - 240 V 50/60 Hz, EMT6-DB1) 2)
24 - 240 V DC
066167

6

230 V 50/60 Hz

EMT6-DB(230V)1) 2)
066401

Accessories
Screw adapters for screw fixing

Documentation
EMT6 thermistor overload relay
Overload monitoring of machines in the EEx e area
German
English
1)

Notes

CS-TE 3)
095853

10 off

AWB2327-1446D
264853
AWB2327-1446GB
267010

1 off
1 off

For EMT6, EMT6(230V), EMT6-DB and EMT6-DB(230V) applies:
Provide additional short-circuit protection in the sensor circuit
with a current monitoring relay.

2)

3)

Information relevant for export to North America

Information relevant for export to North America

Product Standards

UL/CSA certification not required

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Max. Voltage Rating
Degree of Protection

UL 508; CSA-C22.2 No.14;
IEC/EN 60947-4-1; CE marking
E29184
NKCR
12528
3211-03
UL Listed, CSA certified
600 V AC
IEC: IP20, UL/CSA Type: -

–

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

19

1.2

Selection aid

Engineering
Terminal marking according to EN 50005
EMT6(-K), EMT6-(K)DB, EMT6-DBK
Auto

EMT6-(K)DB, EMT6-DBK
Manual
~
L+

~
L+

A1/A2

A1/A2

T1/T2
21

A1
Power

3.6 K
1.6 K
0

T1/T2
Y1 Y2

A1

13

Power

Tripped

21

13

T1 T2

22

1.6 k
0

Y1/Y2, RESET
US

Tripped LED
A2

3.6 K

Tripped

13–14, 21–22

US

13–14, 21–22
22 14

T1 T2

A2

14

Tripped LED

PTC

PTC

N~

N~

EMT6-DBK
Zero-voltage safe operation
LED display

~
L+

A1/A2
T1/T2
Y1 Y2

A1
Power

Y3 Y4

21

13

Supply voltage present

3.6 K
1.6 K
0

Device has tripped

Tripped

Device has tripped/short-circuit in
the sensor circuit

Y1/Y2, RESET
US

13–14, 21–22
T1 T2

A2

22

14

Tripped LED
Short-circuit
PTC

N ~–

Sensor circuit
At R K ̰ 250 ȍ per sensor: 6 sensors, at RK̰100 ȍ per sensor: 9 sensors in
the winding (provided by user), max. cable length to sensor 250 m (not shielded);
Total PTC thermistor resistance ™ R K̰1500 ȍ
Sensor circuit characteristic values at Us and +20 °C

12000

R T1-T2

EMT6…
U T1-T2
V DC max.

I T1-T2
mA max.

T1, T2 short-circuited
4 kȍ
T1-T2 open

3
5.1

1.9
0.8
-

Resistance [ ]

1

Overload relays for machine protection

4000

3600

IECTripping range

1650

Resetting
range

1600

Disconnection by link

Short-circuit monitoring
Zero-voltage safety

Y1 - Y 3
Y1 - Y 4

20

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Reset

750

Tolerance limits
Temperature [°C]

Functions that can be disconnected on the EMT6-DBK:
Function

Tripping

60

NAT NAT
–20° –5°

NAT

NAT
NAT
+5° +15°

Overload relays
Accessories

1.2

Ordering

1

ZB, Z5, ZW7
For use with Part no.
Article no.

Std. pack

Notes

AWB2300-1425D
258704
AWB2300-1527D/GB
284910
AWB2300-1545D/GB
102065

1 off

German

1 off

German/English

1 off

German/English

ZB32

ZB32-XEZ
278473

5 off

ZB65

ZB65-XEZ
278474

2 off

Can be snap fitted on a
top-hat rail to IEC/EN 60715
or can be screw fitted.
For ZB32-38, use
BK25/3-PKZ0 additionally.

ZW7...
ZE
Z5
ZB12
ZB32
ZB65
ZB150

M22-DZ-B
254833

10 off

ZW7...
ZE
Z5
ZB12
ZB32
ZB65
ZB150

M22-DZ-B-GB14
254834

10 off

Button plate, blue RESET

Pushbuttons
For enclosed
Overload relay
Mounting diameter: 22.3 mm
Off button, IP65

ZW7...
ZE
Z5
ZB12
ZB32
ZB65
ZB150

M22-DZ-X
254835

10 off

Without button plate,
add button plate.

Pushbuttons
For enclosed
Overload relay
Mounting diameter: 22.3 mm
Button plates

M22-DZ-X

M22-XD-R
216423
M22-XD-R-X0
218153

Documentation
Overload relays
Overload monitoring of
EEx e motors

Bases
For separate mounting

Pushbuttons
For enclosed
Overload relay
Mounting diameter: 22.3 mm
External reset button, IP65

ZE…
ZB12…
ZB32…
ZB65…
ZB150…

M22-DZ-X
M22-DZ-X

Price
See price
list

Button plate, blue

Information relevant for export to
North America

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Max. Voltage Rating
Degree of Protection
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

M22-XD-R-GB0
218194

10 off

Button plate, red

UL 508; CSA-C22.2 No.14;
IEC/EN 60947-4-1; CE marking
E29184
NKCR
12528
3211-03
UL Listed, CSA certified
600 V AC
IEC: IP00, UL/CSA Type: UL 508; CSA-C22.2 No.14;
IEC/EN 60947-4-1; CE marking
E29184
NKCR
12528
3211-03
UL Listed, CSA certified

UL 508; CSA-C22.2 No.14;
IEC/EN 60947-4-1; CE marking
E29184
NKCR
12528
3211-03
UL Listed, CSA certified

UL/CSA certification not required

Red button plate with white
circle
Button plate red STOP

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

21

1.2

Overload relays
Accessories

Z5..., K-B..., KS-B...

1

Covers

For use with

Part no.
Article no.

Direct mounting Z5-…/FF225 to
DILM185A
DILM225A

Z5/FF225A-XHB-Z
139579

Price
See price list

Std. pack

Notes

1 off

Fitted directly to the contactor
DILM400
-XHB
DILM185A/
225A
Z5/FF225A
-XHB-Z
Z5-.../FF225A
Z5/FF250
-XHB

Z5-…/FF225A
Z5-…/FF250

Covers

Z5/FF250-XHB
215217

1 off

Separate mounting
Z5/FF250
-XHB
Z5-.../FF250/
FF225A
Z5/FF250
-XHB

Direct mounting Z5-…/FF250 to
DILM250
DILM300A

Covers

Z5/FF250-XHB-Z
215218

1 off

Fitted directly to
the contactor

Fitted directly to
the contactor

DILM400
-XHB

DILM400
-XHB

DILM250/
300A

DILM185A/
225A

Z5/FF250
-XHB-Z

Z5/FF225A
-XHB-Z

Z5-.../FF250

Z5-.../FF225A

Z5/FF250
-XHB

Z5/FF250
-XHB

Fitted directly to the contactor
DILM400
-XHB
DILM250/
300A
Z5/FF250
-XHB-Z
Z5-.../FF250
Z5/FF250
-XHB

Box terminals kit
Consisting of 3 individual clamps
For use with

For
connection
of copper
flat strip
max.
WxH
mm

Part no.
Article no.

With protective cover

Z5-…/FF250

24 x 26

With control circuit terminal
and protective cover

Z5-…/FF250

24 x 26

22

Price
See price list

Std. pack

Notes

K-B-DIL6AM
064062

1 off

When using box terminals the
protective covers must be used.

KS-B-DIL6AM
064063

1 off

When using box terminals the
protective covers must be used.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.2

Overload relays
Selection criteria

Engineering

1

Protection of single-phase and DC current motors:

Mounting position:

1 pole

ZE

2 pole

ZB12, ZB32, ZB65, ZB150, Z5

Tripping characteristics
These tripping characteristics are mean values of the spread at 20 °C ambient temperature in a cold state.
They show the tripping times in relation to the response current. When the devices are at operational temperature the tripping time of the overload
relay drops to approx. 25% of the value shown. Specific characteristics for each individual setting range can be found in the manual on
Page 21

1 1.5 2 3 4 6 8 10 15 20
x Setting current

Minutes
3-phase

2-phase

1 1.5 2 3 4 6 8 10 15 20
x Setting current

2h
100
60
40
20
10
6
4
2
1
40
20
10
6
4
2
1
0.6

Z5

Minutes

ZW7

Maximum

3 phase

Seconds

2-phase

2h
100
60
40
20
10
6
4
2
1
40
20
10
6
4
2
1
0.6

ZB150

Minimum

Seconds

3-phase

Seconds

Seconds

2h
100
60
40
20
10
6
4
2
1
40
20
10
6
4
2
1
0.6

Minutes

ZB12, ZB32,
ZB65, ZE

Minutes

2h
100
60
40
20
10
6
4
2
1
40
20
10
6
4
2
1
0.6

1 1.5 2 3 4 6 8 10 15 20
x Setting current

2 phase

1 1.5 2 3 4 6 8 10 15 20
x Setting current

Adaption of ZW7 to smaller rated motor currents
Number of loops

ZW7 -63

-90

1
2
3
4
5

Rated motor current IN [A]
42-63
60-90
21-31,5
30-45
14-21
20-30
10.5-15,8
15-22,5
8.4-12,6
12-18

-125

-160

-240

-290

-400

-540

-630

85-125
42.5-62,5
28.3-41,7
21.3-31,3
17-25

110-160
55-80
36.7-53,3
27.5-40
22-32

160-240
80-120
53.3-80
40-60
32-48

190-290
95-145
63.3-96,7
47.5-72,5
38-58

270-400
135-200
90-133,3
67.5-100
54-80

360-540
180-270
120-180
90-135
72-108

420-630
210-315
140-210
105-157,5
84-126

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

23

1.2

Overload relays
UL/CSA-short-circuit strength

1 ZE, ZB, Z5

Overload relay short-circuit strength
UL508, CSA-C22,2 No. 14/SCCR values

ZE-0,16
ZE-0.24
ZE-0.4
ZE-0.6
ZE-1,0
ZE-1.6
ZE-2.4
ZE-4
ZE-6
ZE-9
ZE-12
ZB12(32)-0,16
ZB12(32)-0,24
ZB12(32)-0,4
ZB12(32)-0,6
ZB-12(32)-1,0
ZB-12(32)-1,6
ZB-12(32)-2,4
ZB-12(32)-4
ZB-12(32)-6
ZB-12(32)-10
ZB12-12
ZB12-16
ZB32-16
ZB32-24
ZB32-32
ZB65-10
ZB65-16
ZB65-24
ZB65-40
ZB65-57
ZB65-65
ZB65-75

24

Fuse acc. to NEC, CEC
A
kA

CB
A

600V AC
1
1
1
1
3
6
6
15
20
35
45
600V AC
1 CLASS J/CC
1 CLASS J/CC
1 CLASS J/CC
1 CLASS J/CC
1 CLASS J/CC
3 CLASS J/CC
3 CLASS J/CC
6 CLASS J/CC
10 CLASS J/CC
15 CLASS J/CC
15 CLASS J/CC
30 CLASS J/CC
35 CLASS J
45 CLASS J
60 CLASS J
600V AC
15 CLASS J
35 CLASS J
45 CLASS J
60 CLASS J
110 CLASS J
125 CLASS J
125 CLASS J

480V AC
15
15
15
15
15
15
15
15
15
15
-

5
5
5
5
5
5
5
5
5
5
5
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100

600V AC
40
60
90
125
150
150
150

kA
5
5
5
5
5
5
5
5
5
5
-

ZB150-50
ZB150-70
ZB150-100
ZB150-125
ZB150-150
ZB150-175
ZB150-50(KK)
ZB150-70(KK)
ZB150-100(KK)
ZB150-125(KK)
ZB150-150(KK)
ZB150-175(KK)
Z5-70/...
Z5-100/...
Z5-125/...
Z5-160/...
Z5-220/...
Z5-250/...
Z5-70/...
Z5-100/...
Z5-125/...
Z5-160/...

5
5
5
5
10
10
10

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Fuse acc. to NEC, CEC
A
kA

CB
A

600V AC
225
250
400 CLASS J
500 CLASS J
600 CLASS J
600 CLASS J
110 CLASS J
125 CLASS J
200 CLASS J
250 CLASS J
300 CLASS J
300 CLASS J
600V AC
250
400 CLASS J
500 CLASS J
600 CLASS J
800 CLASS J
700 CLASS J
125 CLASS J
200 CLASS J
250 CLASS J
300 CLASS J

600 V AC
200
250
400
500
600
600
200
250
400
500
600
600
600V AC
250
400
500
600
800
600
-

5
10
10
10
10
10
100
100
100
100
100
100
10
10
10
10
10
10
100
100
100
100

kA
5
10
10
10
10
10
5
10
10
10
10
10
10
10
10
10
10
10
-

1.2

Overload relays
Overload relays

Technical data
1

ZE, ZB
ZE
General
Standards
Climatic proofing

ZB12, ZB32

ZB65

ZB150(KK)

IEC/EN 60947, VDE 0660, UL, CSA
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Ambient temperature
Open 1)
Enclosed 1)
Temperature compensation

°C

-25…50

-25…55

-25…55

-25…55

°C

-25…40
Continuous

-25…40

-25…40

-25…40

kg
g

0.07
10

0.15
10

0.25
10

1.64
10

IP20

IP20

IP00

IP00

Mounting position

Page 23

Weight
Mechanical shock resistance half-sinusoidal shock, 10 ms
to IEC 60068-2-27
Protection type
Protection against direct contact when actuated
from front (EN 50274)
Main contacts
Rated impulse withstand voltage

Finger- and back-of-hand proof

U imp

V AC

Overvoltage category/pollution degree
Rated insulation voltage
AC
Rated operating voltage
Safe isolation according to EN 61140

6000

6000

6000

8000

III/3

III/3

III/3

III/3

Ui

V AC

690

690

690

1000

Ue

V AC

690

690

690

1000

V AC
V AC

300
300

440
440

440
440

440
440

Between auxiliary contacts and main contacts
Between the main contacts
Overload relay setting range

A

0.1…12

0.1…38

6…75

25…175

Temperature compensation residual error > 40 ºC
Short-circuit protection rating maximum fuse

%/K

̰0.25
Page 6

̰0.25
Page 8

̰0.25
Page 10

̰0.25
Page 10

W
W

2.5
6

2.5
6

3
7.5

16
18

Solid
Flexible with ferrule

mm²
mm²

2 x (0.75 - 2.5)
2 x (0.5 - 1.5)

Stranded

mm²

–

2 x (1 - 6) 5)
2 x (1 - 4) 5)
2 x (1 - 6) 3)
–

2 x (1 - 16) 4)
1 × (1…25)
2 x (1…10) 2)
1 x (16…25)

2 x (4 - 16)
1 x (4 - 70)
2 x (4 - 50)
1 x (16…50)
2 x (16…50)

AWG
mm

18 - 14
–

14 - 8 5)
–

14 - 2
–

3/0
–

Current heat loss (3 conductors)
Lower value of setting range
Upper value of setting range
Terminal capacity

Solid or stranded
Busbar

Width

Terminal screw
Tightening torque

M3.5

M4

M6

M10

Nm

1.2

1.85)

3.5

10

Size
mm
mm

2
0.8 x 5.5
–

2
1x6
–

2
1x6
–

–
–
5

Tools
Pozidriv screwdriver
Flat-blade screwdriver
Hexagon socket

Notes

SW
1)

Ambient temperature: Operating range to IEC/EN 60947, PTB: -5°C to +55°C
Use identical cross-section when using two conductors
3) 6 mm flexible with ferrules to DIN 46228
4) With ZB65-XEZ max 1 x (1… 16)
5) ZB32-38: solid and flexible with ferrule, 2.5 - 25 mm², 3 Nm tightening torque.
AWG10-b, 27 lb-in tightening torque for solid or stranded conductors.
2)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

25

1.2

Overload relays
Overload relays, CT-operated overload relays

1 Z5, ZW7
Z5-…/FF225A(250)

ZW7

IEC/EN 60947, VDE 0660, UL, CSA
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

IEC/EN 60947, VDE 0660, UL, CSA

°C

-25…50

-25…50

°C

-25…40
Continuous

-25…40
Continuous

General
Standards
Climatic proofing
Ambient temperature
Open 1)
Enclosed 1)
Temperature compensation
Mounting position
Weight

kg

Page 23
1.55

Any
0.8

Mechanical shock resistance half-sinusoidal shock, 10 ms

g

10

10

IP00
With terminal cover

IP00
Finger- and back-of-hand proof

to IEC 60068-2-27
Protection type
Protection against direct contact when actuated
from front (EN 50274)
Main contacts
Rated impulse withstand voltage
Overvoltage category/pollution degree

U imp

V AC

8000
III/3

6000
III/3

Ui

V AC

1000

690

Ue

V AC

1000

690

V AC
V AC

440
440

440
440

Rated insulation voltage
AC
Rated operating voltage
Safe isolation according to EN 61140
Between auxiliary contacts and main contacts
Between the main contacts
Overload relay setting range

A

50…300

42…630

Temperature compensation residual error > 40 ºC

%/K

̰ 0.25

–

Short-circuit protection rating maximum fuse

Page 12

With overload relay in conjunction
with a transformer as required for the
contactor

Current heat loss (3 conductors)
Lower value of setting range

W

16

3

Upper value of setting range

W

28

10

mm²
mm²

95
120

–
–

AWG
mm

250 MCM
6 x 16 x 0.8 2)

–
–

mm
mm

20 x 3
–

–
27

Nm

M8 x 25
24

–
–

mm

13

–

Terminal capacity
Flexible with ferrule
Stranded with ferrule
Solid or stranded
Flat conductor.
Busbar
Push-through opening

Number of segments x width x thickness
Width

Terminal screw
Tightening torque
Tools
Hexagonal socket

Notes

26

SW
1)

Ambient temperature: Operating range to IEC/EN 60947, PTB: -5°C to +50°C
2) Fixing with box terminals

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.2

Overload relays
Overload relays, CT-operated overload relays

ZE, ZB, Z5, ZW7
ZE
Auxiliary and control circuits
Rated impulse withstand voltage

U imp

V

Overvoltage category/Pollution degree

ZB12, ZB32

ZB65

ZB150(KK)

Z5-.../FF225
Z5-.../FF250

ZW7

6000

6000

6000

6000

6000

6000

III/3

III/3

III/3

III/3

III/3

III/3
2 x (0.75 - 4)

1

Terminal capacity
Solid

mm²

2 x (0.75 - 2.5)

2 x (0.75 - 4)

2 x (0.75 - 4)

2 x (0.75 - 4)

2 x (0.75 - 4)

Flexible with ferrule

mm²

2 x (0.5 - 1.5)

2 x (0.75 - 2.5)

2 x (0.75 - 2.5)

2 x (0.75 - 2.5)

2 x (0.75 - 2.5)

2 x (0.75 - 2.5)

Solid or stranded
Terminal screw

AWG

2 x (18 - 12)
M3.5

2 x (18 - 12)
M3.5

2 x (18 - 12)
M3.5

2 x (18 - 12)
M3.5

2 x (18 - 12)
M3.5

2 x (18 - 12)
M3.5

Tightening torque

Nm

0.8 - 1.2

0.8 - 1.2

0.8 - 1.2

0.8 - 1.2

0.8 - 1.2

0.8 - 1.2

Tools
Pozidriv screwdriver
Flat-blade screwdriver
Auxiliary circuit rated insulation voltage
Rated operating voltage

Size

2

2

2

2

2

2

Ui
Ue

mm
V AC
V AC

0.8 x 5.5
690
500

1x6
500
500

1x6
500
500

1x6
500
500

1x6
500
500

1x6
500
500

V AC

300

240

240

240

240

240

I th

A

6

6

6

6

6

6

Safe isolation according to EN 61140
Between the auxiliary contacts
Conventional thermal current
Rated operational current
AC-15
N/O
120 V

Ie

A

1.5

1.5

1.5

1.5

1.5

1.5

240 V

Ie

A

1.5

1.5

1.5

1.5

1.5

1.5

415 V

Ie

A

0.5

0.5

0.5

0.5

0.5

0.5

500 V

Ie

A

0.3

0.5

0.5

0.5

0.5

0.5

NC
120 V

Ie

A

1.5

1.5

1.5

1.5

1.5

1.5

240 V
415 V

Ie
Ie

A
A

1.5
0.7

1.5
0.9

1.5
0.9

1.5
0.9

1.5
0.9

1.5
0.9

500 V

Ie

A

0.5

0.8

0.8

0.8

0.8

0.8
0.9

DC-13 L/R ̰ 15 ms 1)
24 V

Ie

A

0.9

0.9

0.9

0.9

0.9

60 V

Ie

A

0.75

0.753)

0.753)

0.753)

0.753)

0.753)

110 V
220 V

Ie
Ie

A
A

0.4
0.2

0.4
0.2

0.4
0.2

0.4
0.2

0.4
0.2

0.4
0.2

AC operated

V

–

–

–

–

–

AC operated

A

–

–

–

–

–

General Use

DC operated

V

240
600
1.5
0.6
–

–

–

–

–

–

DC operated

A

–

–

–

–

–

–

AC operated

D300

DC operated

R300

B300 4)
B600 5)
R300

B300 4)
B600 5)
R300

B300 4)
B600 5)
R300

B300 4)
B600 5)
R300

B300 4)
B600 5)
R300

4

6

6

6

6

6

Pilot Duty

Short-circuit rating without welding
Max. fuse 2)

Notes

A gG/gL

1)

Making and breaking conditions to DC-13, time constant as stated
2) See transparent overlay "Fuses" for time/current characteristics (please enquire)
3) Rated operational current DC-13, 60 V: N/O auxiliary contact 0.6 A
4) With opposite polarity
5) With same polarity

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

27

1.2

Electronic overload relays to 1500 A

ZEB
ZEB12, ZEB32

1
General
Standards
Climatic proofing

ZEB65-45

ZEB65-100

ZEB150

IEC/EN 60947, VDE 0660, UL, CSA
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Ambient temperature
Open
Enclosed
Temperature compensation
Mounting position
Mechanical shock resistance half-sinusoidal shock, 10 ms
to IEC 60068-2-27
Protection type
Protection against direct contact when actuated
from front (EN 50274)
Main contacts
Rated impulse withstand voltage
Overvoltage category/pollution degree
Rated insulation voltage
AC
Rated operating voltage
Safe isolation according to EN 61140
Between auxiliary contacts and main contacts
Between the main contacts
Overload relay setting range
Terminal capacity
Solid
Solid or stranded
Auxiliary and control circuits
Rated impulse withstand voltage
Overvoltage category/pollution degree
Terminal capacity
Solid
Flexible with ferrule
Solid or stranded
Terminal screw
Terminal screw
Tightening torque
Tools
Pozidriv screwdriver
Flat-blade screwdriver
Auxiliary circuit rated insulation voltage
Rated operating voltage
Safe isolation according to EN 61140
Between the auxiliary contacts
Conventional thermal current
Rated operational current

°C
°C

–25…65
–25…65
Continuous
Any

–25…65
–25…40
Continuous
Any

–25…65
–25…40
Continuous
Any

–25…65
–25…40
Continuous
Any

g

15

15

15

15

IP20
IP20
Finger- and back-of-hand proof

IP20

IP20

U imp

V AC

6000
III / 3

6000
III / 3

6000
III / 3

6000
III / 3

Ui
Ue

V AC
V AC

690
690

690
690

690
690

690
690

V AC
V AC
A

600
600
0.3…45

600
600
9…45

600
600
20…100

600
600
20…100

mm²
AWG

1 x 2.5 - 16
1 x 14 - 4

1 x 2.5 - 16
1 x 14 - 4

1 x 6 - 50
1 x 10 - 1

1 x 6 - 50
1 x 10 - 1

V

6000
III / 3

6000
III / 3

6000
III / 3

6000
III / 3

mm²
mm²
AWG

2 x (0.75 - 4)
2 x (0.75 - 2.5)
2 x (18 - 12)
M3.5

2 x (0.75 - 4)
2 x (0.75 - 2.5)
2 x (18 - 12)
M3.5

2 x (0.75 - 4)
2 x (0.75 - 2.5)
2 x (18 - 12)
M3.5

2 x (0.75 - 4)
2 x (0.75 - 2.5)
2 x (18 - 12)
M3.5

Nm
lb-in

0.8 - 1.2
7 - 10.6

0.8 - 1.2
7 - 10.6

0.8 - 1.2
7 - 10.6

0.8 - 1.2
7 - 10.6

Ui
Ue

Size
mm
V AC
V AC

2
1x6
500
500

2
1x6
500
500

2
1x6
500
500

2
1x6
500
500

I th

V AC
A

240
5

240
5

240
5

240
5

Ie
Ie
Ie
Ie

A
A
A
A

1.5
1.5
0.5
0.5

1.5
1.5
0.5
0.5

1.5
1.5
0.5
0.5

1.5
1.5
0.5
0.5

Ie
Ie
Ie
Ie

A
A
A
A

1.5
1.5
0.9
0.8

1.5
1.5
0.9
0.8

1.5
1.5
0.9
0.8

1.5
1.5
0.9
0.8

Ie
Ie
Ie
Ie

A
A
A
A

0.9
0.75
0
0.2

0.9
0.75
0.4
0.2

0.9
0.75
0.4
0.2

0.9
0.75
0.4
0.2

A gG/gL

6

6

6

6

U imp

AC-15
N/O
120 V
240 V
415 V
500 V
NC
120 V
240 V
415 V
500 V
DC-13 L/R ̰15 ms
24 V
60 V
110 V
220 V
Short-circuit rating without welding
Max. fuse
28

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Thermistor machine protection relays

1.2

EMT6
EMT6
General
Standards
Climatic proofing

1

IEC/EN 60947, VDE 0660, EN 55011
Damp heat, constant, to IEC 60068-2-78;
Damp heat, cyclic, to IEC 60068-2-30

Ambient temperature
Open

°C

-25…60

Enclosed
Storage
Mounting position
Weight

°C
°C

-25…45
-45 - 60
Any
0.15

Shock resistance half-sinusoidal shock 10 ms to IEC 60068-2-27
Protection type

g

kg

Protection against direct contact when actuated from front (EN 50274)
Safe isolation according to EN 61140

Finger- and back-of-hand proof

Between the contacts
Between contacts and supply voltage
Auxiliary and control circuits
Rated impulse withstand voltage

10
IP20

U imp

V AC

250

V AC

250

V AC

Overvoltage category/pollution degree
Auxiliary and control circuit terminal capacity

6000
III/3

Solid

mm²

AWG

1 x 2.5
2 x (0.5 - 1.5)
1 x 2.5
2 x (0.5 - 1.5)
20 - 14

Flexible with ferrule

mm²

Terminal screw
Tightening torque

Solid or stranded

Nm

M3.5
1.2

Tools
Pozidriv screwdriver

Size

2

mm

1x6

Ui

V

400

415 V

Ie

A

3

415 V

Ie

A

3

240 V

Ie

A

3

415 V

Ie

A

1

Ie
Ie

A
A

3
1

Flat-blade screwdriver
Auxiliary circuit
Rated insulation voltage
Rated operational current
AC-14
N/O
NC
AC-15
N/O

NC
240 V
415 V
Max. short-circuit protective device
Fuse
Control circuit
Rated insulation voltage
Rated operational voltage
Voltage tolerance
Power consumption

gG/gL
Ui

V

240

Ue

V
x Ue

2401)
0.85 - 1.1

VA
W
ȍ
ȍ

3.5
2
̱3600
̰1600

AC
DC
Trip at approx.
Reset at approx.
Notes

6

1)

EMT6(-DB)230V: Ue = 230 V

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

29

1.2

Overload relays

Dimensions
Overloadrelays

Base

ZE-…

ZB32-XEZ

ZB65-XEZ

5.5

49

b2

b1

b

2xd

106

5

c2

58

32
45

a1

c

16.5
a

a
b
c
c2
a1
b1
b2
d

>5
=

ZB32

62
27.5

136

53

120

42

34

ZB12

84
88

39
45

27.5

102
39

OFF
Reset/ON

45

ZB32-38

120

136

62

42

OFF
Reset/ON

25

2

1

Overload relays

27.5

102
39
45

30

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

ZB32
45
85
90.5
3.8
35
75
40.5
M4

ZB65
60
86
112
4.7
50
75
47
M5

Overload relays
Overload relays

1.2

Overload relays

1

ZB65

40

172

OFF
Reset/ON

35

7.5
46.5

96.5
132

60

ZB150
90

160

70

OFF
Reset/ON

44

74

91

277

156

170

150

7

5

134
16.5
95
100
118

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

31

1.2

Overload relays
Overload relays, CT-operated overload relays

1 Overload relays
ZB150-50/KK
OFF
Reset/ON

100

7

121

74

7

5

63
16.5

129

95

134

99
118

Z5 overload relays greater than 150A
Z5-.../FF250
OFF
Reset/ON

121
110
96
144
48

25

94

169

144

74

7

111

7

5

11

16.5
128

Current transformer-operated overload relays
ZW7-…
1.5

7.5

4.3

55

85

55

44
26

26

44

33

71

21

8

185
M4

185

159
172 – 250

200
65

71

65

90°

27

32

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

90°

90°

Reset/ON

Overload relays
Electronic overload relays

1.2

Electronic overload relays

1

ZEB12

ZEB32
117

139.5

76

43
79

161

143

70

34

97.5

103

33.2

108

40.5

103

33.2

45

108

40.5
45

ZEB65-45

ZEB65-100
146.1

146.1

132.5

213.6

57.5
107

184

87

57.5

132.5

5

33.2
40.5
45

103
108
38.6
46.2

128.2
136.3

55

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

33

1.2

Overload relays
Electronic overload relays

1 Electronic overload relays
ZEB150-100
111.8

175
160

289.1

145.4

85

90

38.6

132.4

63.2

140.5

116

104.8

51.7

ZEB150-100/KK

41

132.4

38.6

140.5

46.1
56

34

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.2

Overload relays
Thermistor overload relays for machine protection, electronic overload relays

Thermistor overload relays for machine protection, electronic overload relays

Current sensors

1
ZEB-XCT600
206

89.2

127

193.5

234.2

165.1

106.1

190.5

205.4

ZEB-XCT300

ZEB-XCT1000
ZEB-XCT1500

330.2

188.9

304.6

317

10.1

83.5

383.5

Ø 73.2

108

108

EMT6 thermistor overload relays for machine protection

External reset button

EMT6…

M22-DZ-B
M22-DZ-X
100
78

19

3.2

102

24.1

_> 3

Ø 29.5

2.5
22.5

8
22.3
2–5

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

35

C441 overload and monitoring relay
Product description

C441 overload and monitoring relay

1.2

C441 overload and monitoring relay
Features and benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog number selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical data and specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
38
41
42
43
48
60

C441 overload and monitoring relay
Product description
Eaton’s Motor Insight, the
first product in the Intelligent
Power Control Solutions
family, is a highly configurable
motor, load and line
protection device with power
monitoring, diagnostics and
flexible communications
allowing the customer to
save energy, optimize their
maintenance schedules and
configure greater system
protection, thus reducing
overall costs and downtime.

Motor Insight is available
in either a line-powered or
120 Vac control powered
design, capable of monitoring
voltages up to 660 Vac. Each
of these units is available in
a 1–9 amp or a 5–90 amp FLA
model. With external CTs,
Motor Insight can protect
motors up to 540 amps FLA.
Available add-on accessories
include communication
modules for Modbus RTU,
DeviceNet, PROFIBUS,
Modbus TCP, EtherNet/IP and
HTTP web services all with I/O
options. For ease-of-use and
operator safety, Motor Insight
offers a remote display that
mounts easily with two
30 mm knockouts.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

37

1.2

C441 overload and monitoring relay
Features and benefits

1 Features and Benefits
Benefits

Features
Size/Range
Broad FLA range of 1–540A
Selectable trip class (5–30)
Four operating voltage
options
Line-powered from
240 Vac, 480 Vac,
600 Vac
Control-powered from
120 Vac
Motor Control
Two output relays
One B300 Form C fault
relay and one B300
ground fault shunt relay
Other relay configurations
are available, including
one Form A and one
Form B SPST (fault and
auxiliary relays) allowing
programmable isolated
relay behavior and
unique voltages
One external remote
reset terminal
Trip status indicator
Motor Protection
Thermal overload
Jam protection
Current imbalance
Current phase loss
Ground fault
Phase reversal

Line Protection
Over voltage
Under voltage
Voltage imbalance
Voltage phase loss
Monitoring Capabilities
Current—average and
phase rms
Voltage—average and
phase rms
Power—motor kW
Power factor
Frequency
Thermal capacity
Run hours
Ground fault current
Current imbalance %
Voltage imbalance %
Motor starts
Motor run hours
Options
Type 1, 12 remote display
Type 3R remote display kit
Communication modules
Modbus
Modbus with I/O
DeviceNet with I/O
PROFIBUS with I/O
Modbus TCP with I/O
EtherNet/IP with I/O

Reliability and Improved Uptime
Advanced diagnostics
allows for quick and
accurate identification of
the root source of a motor,
pump or power quality
fault; reducing troubleshooting time and the loss
of productivity, reducing
repeat faults due to
misdiagnosis, and
increasing process output
and profitability
Provides superior
protection of motors and
pumps before catastrophic
failure occurs
Increases profitability with
greater process uptime
and throughput, reduced
costs per repair, reduced
energy consumption and
extended equipment life
Adjustments to overload
configuration can be made
at any time
Safety
IP20 rated terminal blocks
Terminal blocks are set back
from the display to reduce
operator shock hazard
Remote display (optional)
does not require that the
operator open the panel to
configure the device

Load Protection
Under current
Low power (kW)
High power (kW)

Standards and Certifications
cULus listed NKCR,
NKCR7, 508
UL® 1053 applicable
sections for ground fault
detection

38

CSA® certified
(Class 3211-02)
CE
NEMA®

IEC EN 60947-4-1
RoHS
CCC

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Flexibility
Communications modules
Offered in a variety of
configurations
External snap-on modules
provide support for
multiple communications
protocols
Advanced power, voltage
and current monitoring
capabilities
Communications modules
and remote display can be
used simultaneously
Highly configurable fault
and reset characteristics
for numerous applications
Fully programmable
isolated fault and auxiliary
relays
Ease of Use
Bright LED display with
easy-to-understand setting
and references
Powered from line voltage
or 120 Vac control power
Remote display powered
from base unit
Full word descriptions and
units on user interface

C441 overload and monitoring relay
Features and benefits

1.2

Advanced Overload Education
Description

1
Motor Insight
Protection

Definition

Source

Result

Overload is a condition in which current
draw to a motor exceeds 115% of
the full load amperage rating over a
period of time for an inductive motor.

An increase in the load or torque that
is being driven by the motor.

Increase in current draw. Current leads
to heat and insulation breakdown,
which can cause system failure.
Additionally, an increase in current can
increase power consumption and
waste valuable energy.

Thermal trip behavior is defined by UL,
CSA and IEC standards.

The motor attempts to drive the load,
which has more resistive force due to
the mechanical interference. In order to
drive the load, the motor draws an
abnormal amount of current, which can
lead to insulation breakdown and
system failure.

Provides a configurable Jam setting that
is active during “motor run state” to avoid
nuisance trips.

An undetected ground fault can burn
through multiple insulation windings,
ultimately leading to motor failure.

Motor Insight has ground fault protection
capability down to 0.15 amps estimated
from the existing three-phase CTs using
the residual current method. That is, the
three-phase current signals should sum to
zero unless a ground fault (GF) condition
is present. In the case of a GF, Motor
Insight can alarm, trip the starter, or trip
an alternative relay that can be used to
shunt trip a breaker or light up a warning
light. GF current can also be monitored in
real-time through the advanced
monitoring capabilities.

Motor Protection
Thermal overload

A low voltage supply to the motor would
cause the current to go high to maintain
the power needed.

Trip class is settable from 5–30 by 1
Provides power factor monitoring and low
voltage protection features.

A poor power factor would cause
above normal current draw.
Jam

Ground fault

Jam is similar to thermal overload in
that it is a current draw on the motor
above normal operating conditions.

A line to ground fault.

Mechanical stall, interference, jam or
seizure of the motor or motor load.

A current leakage path
to ground.

Trip Threshold 150–400% of FLA.
Trip Delay 1–20 seconds.

Note: GF settable thresholds vary with
motor FLA. 0.15 amps may not be
available in all cases.
Provides two protection settings that
address this problem. The user can
choose to set current imbalance
thresholds or voltage imbalance
thresholds, each of which can trip the
starter. Additionally, both of these may
be monitored through Motor Insight’s
advanced monitoring capabilities,
allowing the customer to notice in realtime when and where a condition is
present.

Imbalanced phases
(voltage and current)

Uneven voltage or currents between
phases in a three-phase system.

When a three-phase load is powered with Imbalanced voltage causes large
a poor quality line, the voltage per phase imbalanced currents and as a result this
can lead to motor stator windings being
may be imbalanced.
overloaded, causing excessive heating,
reduced motor efficiency and reduced
insulation life.

Phase loss—current
(single-phasing)

One of the three-phase current is
not present.

Multiple causes, loose wire, improper
wiring, grounded phase, open fuse,
and so on.

Phase rotation
(phase-reversal)

Improper wiring, leading to phases being A miswired motor. Inadvertent phaseconnected to the motor improperly.
reversal by the utility.

Phase-reversal can cause unwanted
directional rotation of a motor. In the
event that the load attached to the motor
can only be driven in one direction, the
result could be significant mechanical
failure and/or injury to an operator.

Configurable phase protection, allowing
the user to define the phase sequencing
intended for that application. If no phase
sequence is required, the user has the
ability to disable this feature.

Frequency variance

When line frequency
is inconsistent.

Variations in frequency can cause
increases in losses, decreasing the
efficiency of the motor. In addition,
this can result in interference with
synchronous devices.

Advanced monitoring capabilities
allow the user to monitor frequency
in real-time.

Malfunctioning alternator speed
regulator, or poor line quality caused by
an overload of a supply powered
by individual sources.

Single-phasing can lead to unwanted
Fixed protective setting that takes the
motor vibrations in addition to the results starter offline if a phase drops below
of imbalanced phases as listed above.
60% of the other two phases.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

39

1.2

C441 overload and monitoring relay
Features and benefits

1 Advanced Overload Education, continued
Description

Motor Insight
Protection

Definition

Source

Result

Under current or
low power

Average rms current provided to the
motor falls below normal operating
conditions.

Under current is usually associated
with a portion of the user’s load
disappearing. Examples of this would
be a broken belt, a dry-pump (low
suction head) or a dead-headed
centrifugal pump.

If under current goes undetected, a
mechanical failure can and has
occurred. In the case of a pump,
running a pump dry or running a pump
in a dead-headed condition can cause
excessive heating, damaging
expensive seals and breaking down
desired fluid properties.

Motor Insight has two protection settings
to detect this: under current and low
power. Low power is a more consistent
way of ensuring detection as power is
linear with motor load, where as current
is not. An unloaded motor may draw 50%
of its rated current, but the power draw
will be less than 10% of rated power due
to a low power factor.

High power

The motor load is drawing more power
than it should at normal operating
conditions.

This is typical of batch processing
applications where several ingredients
flow into a mixer. When a substance’s
consistency changes and viscosity
increases from what is expected, the
motor may use more power to blend
the mixture. Out-of-tolerance
conditions can be detected using the
High Power and Low Power settings.

If a high-power fault goes undetected,
the result may be a batch of material
that does not meet specification.

Monitors the three-phase real power. If
the real power value is estimated above
the set threshold for the set length of
time, a fault is detected and the overload
will trip the starter. Additionally, power
can be monitored in real-time.

Over voltage

When the line voltage to the motor
exceeds the specified rating.

Poor line quality.

An over voltage condition leads to a
lower than rated current draw and a
poor power factor. A trip limit of 110%
of rated voltage is recommended. Over
voltage can also lead to exceeding
insulation ratings.

Monitors the maximum rms value of
the three-phase voltages. If the rms
value rises above the set threshold for the
set length of time, a fault is detected and
the overload can trip the starter or send
and display an alarm of the condition. All
line-related faults have an “alarm-notrip” mode.

Under voltage

When the line voltage to the motor is
below the specified rating.

Poor line quality.

An under voltage condition leads to
excessive current draw. This increases
the heating of the motor windings and
can shorten insulation life. A trip limit
set to 90% of rated voltage is
recommended.

Monitors the minimum rms value of the
three-phase voltages. If the rms value
drops below the set threshold for the
set length of time, a fault is detected
and the overload can trip the starter or
send and display an alarm of the
condition. All line-related faults have
an “alarm-no-trip” mode.

Power-up delay

Allows for starting motors and loads
in a deliberate fashion.

When there is a power failure, or
power cycle, multiple loads come
online simultaneously.

Multiple loads starting simultaneously
can cause sags affecting the operation
of devices that may prevent successful
startup.

Configurable to delay closing the fault
relay on power-up. For each Motor Insight
controlling a motor, a different setting can
be programmed, helping to maintain the
integrity of your line power.

Load Protection

Line Protection

If power is lost to a motor driving a
pump, it may be necessary to delay a
restart to allow the pump to come to a
complete stop to prevent starting a
motor during backspin.

40

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

C441 overload and monitoring relay
Catalog number selection

1.2

Catalog Number Selection

1

Motor Insight Overload Relays

C441 B A NOUI
Device Type
C441 = Motor Insight overload relay

Overload Relay
Power Source Voltage
B
= 240 Vac (170–264 Vac)
C
= 480 Vac (323–528 Vac)
D
= 600 Vac (487–660 Vac)
Blank = 120 Vac control power
(170–660 Vac)

Overload Relay Current Rating
A
= 1–9A (1–540A refer to
Page 42 )
B
= 5–90A (5–90A refer to
Page 42 )
0109 = 120 Vac control power
(0–660 Vac, 1–9A)
0590 = 120 Vac control power
(0–660 Vac, 5–90A)

Internal User Interface
Blank = With user interface
(line powered models)
NOUI = Without user interface
(120 Vac control models)

Motor Insight Overload Relays—Communications Modules and Accessory Types

C441 K
Device Type
C441 = Motor Insight overload relay

Communication Module
DeviceNet module 4IN/2OUT 120 Vac
DeviceNet module 4IN/2OUT 24 Vdc
Modbus RTU module
Modbus RTU module 4IN/2OUT 120 Vac
Modbus RTU module 4IN/2OUT 24 Vdc
PROFIBUS module 4IN/2OUT 120 Vac
Modbus TCP / EtherNet/IP module
4IN/2OUT 120 Vac
S = PROFIBUS module 4IN/2OUT 24 Vdc
T = Modbus TCP / EtherNet/IP module
4IN/2OUT 24 Vdc
Accessory Type
1 = Type 1 and 12 remote mounted display
3 = Type 3R kit for remote display
CMP1 = Conversion plate
K
L
M
N
P
Q
R

=
=
=
=
=
=
=

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

41

1.2

C441 overload and monitoring relay
Product selection

1 Product Selection
Motor Insight

Motor Insight
Power Source

Monitoring
Range

Current
Range

Catalog
Number

240 Vac (170–264)

170–264 Vac

1–9A

C441BA

5–90A

C441BB

1–9A

C441CA

5–90A

C441CB

1–9A

C441DA

5–90A

C441DB

1–9A

C4410109NOUI

5–90A

C4410590NOUI

480 Vac (323–528)

323–528 Vac

600 Vac (489–660)

489–660 Vac

120 Vac (93.5–132)

170–660 Vac

Motor Insight CT Multiplier and Wire Wrap Schedule
Motor
FLA

Catalog
Number Ŀ

Number
of Loops

Number of
Conductors Through
CT Primary

CT
Multiplier
Setting

External CT Kit
Catalog Number ŀ

Current Range: 5–90A
C441_B and
C4410590NOUI

5–22.5A

3

4

4

—

6.67–30A

2

3

3

—

10–45A

1

2

2

—

20–90A

0

1

1

—

1–5A

1

2

2

—

2–9A

0

1

1

—

Current Range: 1–9A
C441_A and
C4410109NOUI

60–135A

0

1

150–(150:5)

C441CTKIT150

120–270A

0

1

300–(300:5)

C441CTKIT300

240–540A

0

1

600–(600:5)

C441CTKIT600

Notes
Ŀ Underscore indicates Operating Voltage Code required.
Operating Voltage Codes:
Code

Voltage

B

240 Vac

C

480 Vac

D

600 Vac

 120 Vac Control Power
ŀ

42

Any manufacturer’s CTs may be used.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

C441 overload and monitoring relay
Accessories

1.2

Accessories

1

Modbus Communication Module
The Motor Insight Modbus
Communication Module
is a side-mounted device
providing Modbus
communication capability
to the Motor Insight
overload relay.
The Modbus Communication
Module with I/O provides
communication, monitoring
and control for the Motor
Insight overload relay.

Features and Benefits
The Modbus
communication module is
capable of baud rates
up to 115K
The Modbus address and
baud rate configuration can
be easily changed using
the Motor Insight user
interface (C441M only)
Modbus address and baud
rate are set via convenient
DIP switches (C441N and
C441P); LEDs are provided
to display Modbus traffic
Configuration with
common Modbus
configuration tools

Terminals
Unique locking
mechanism provides for
easy removal of the
terminal block with the
field wiring installed
Each terminal is marked
for ease of wiring and
troubleshooting
Selectable I/O assemblies
4IN/2OUT
Signal types include
24 Vdc I/O and
120 Vac I/O

Each I/O module is
optically isolated
between the field I/O
and the network adapter
to protect the I/O and
communication circuits
from possible damage
due to transients and
ground loops
Input Module features a
user-definable input
debounce, which limits
the effects of transients
and electrical noise
Output Module supports
a user-definable safe
state for loss of
communication; hold
last state, ON or OFF

Modbus Communication Module
Description

I/O

Catalog
Number

Modbus Module

Modbus Communication Module

None

C441M

Modbus with
I/O Module

Modbus Communication Module 4IN/2OUT

120 Vac

C441N

Modbus Communication Module 4IN/2OUT

24 Vdc

C441P

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

43

1.2

C441 overload and monitoring relay
Product selection

1 DeviceNet Communication Modules
The DeviceNet
Features and Benefits
Communication Module
Communication to
provides monitoring and
DeviceNet uses only one
control for the Motor Insight
DeviceNet MAC ID
overload relay from a single
Configuration
DeviceNet node. These
DeviceNet MAC ID and
modules also offer convenient
Baud rate are set via
I/O in two voltage options,
convenient DIP switches
24 Vdc and 120 Vac.
with an option to set
from the network
Advanced configuration
available using common
DeviceNet tools
Terminals
Unique locking
mechanism provides for
easy removal of the
terminal block with the
field wiring installed
Each terminal is marked
for ease of wiring and
troubleshooting

DeviceNet Module

44

Selectable I/O assemblies
4IN/2OUT
Signal types include
24 Vdc I/O and
120 Vac I/O
Each I/O module is
optically isolated
between the field I/O
and the network adapter
to protect the I/O and
communication circuits
from possible damage
due to transients and
ground loops

DeviceNet Modules
Description

I/O

Catalog
Number

DeviceNet Communication Module

120 Vac

C441K

DeviceNet Communication Module

24 Vdc

C441L

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Input Module features a
user-definable input
debounce, which limits
the effects of transients
and electrical noise
Output Module supports
a user-definable safe
state for loss of
communication; hold
last state, ON or OFF
Combined status LED

C441 overload and monitoring relay
Accessories

PROFIBUS Communication Module
The Motor Insight PROFIBUS
Communication Module
is a side-mounted device
providing PROFIBUS
communication capability
to the Motor Insight
overload relay.
The PROFIBUS
Communication Module
with I/O provides
communication, monitoring
and control for the Motor
Insight overload relay.

PROFIBUS with
I/O Module

1.2
1

Features and Benefits
The PROFIBUS
communication module is
capable of baud rates
up to 12 Mb
PROFIBUS address is
set via convenient DIP
switches (C441Q and
C441S); LEDs are
provided to display
PROFIBUS status
Intuitive configuration
with common PROFIBUS
configuration tools

Terminals
Unique locking
mechanism provides for
easy removal of the
terminal block with the
field wiring installed
Each terminal is marked
for ease of wiring and
troubleshooting
Selectable I/O assemblies
4IN/2OUT
Signal types include
24 Vdc I/O and
120 Vac I/O

Each I/O module is
optically isolated
between the field I/O
and the network adapter
to protect the I/O and
communication circuits
from possible damage
due to transients and
ground loops
Input Module features a
user-definable input
debounce, which limits
the effects of transients
and electrical noise
Output Module supports
a user-definable safe
state for loss of
communication; hold
last state, ON or OFF

PROFIBUS Communication Module
I/O

Catalog
Number

PROFIBUS Communication Module 4IN/2OUT

120 Vac

C441S

PROFIBUS Communication Module 4IN/2OUT

24 Vdc

C441Q

Description

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

45

1.2

C441 overload and monitoring relay
Accessories

1 Ethernet Communication Module
The Motor Insight Ethernet
Communication Module
is a side-mounted device
providing both Modbus
TCP and EtherNet/IP
communication capabilities
with built-in HTTP web
services to the Motor Insight
overload relay.
The Ethernet Communication
Module with I/O provides
communication, monitoring
and control for the Motor
Insight overload relay.

Ethernet with
I/O Module

Features and Benefits
Supports Modbus TCP or
EtherNet/IP in a single
device
Contains internal
embedded switch which
provides two Ethernet
ports allowing linear or ring
network configurations
Embedded web services
allow for simple
configuration and
monitoring through
Internet Explorer
IP Address is set via
convenient DIP Switches
located on the device

Ethernet Communication Module
Description

46

Terminals
Unique locking
mechanism provides for
easy removal of the
terminal block with the
field wiring installed
Each terminal is marked
for ease of wiring and
troubleshooting
Selectable I/O assemblies
4IN/2OUT
Signal types include
24 Vdc I/O and
120 Vac I/O

I/O

Catalog
Number

Modbus TCP / EtherNet/IP Communication Module 4IN/2OUT

120 Vac

C441R

Modbus TCP / EtherNet/IP Communication Module 4IN/2OUT

24 Vdc

C441T

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Each I/O module is
optically isolated
between the field I/O
and the network adapter
to protect the I/O and
communication circuits
from possible damage
due to transients and
ground loops
Input Module features a
user-definable input
debounce, which limits
the effects of transients
and electrical noise
Output Module supports
a user-definable safe
state for loss of
communication; hold
last state, ON or OFF

C441 overload and monitoring relay
Accessories

Type 3R Kit with Remote Display Mounted Inside
Features and Benefits
Motor Insight offers several
accessories for the
Remote display unit:
customer’s ease of use
Same user interface as
and safety:
the overload relay
Types 1 and 12 remote
Enhanced operator
display
safety—operator can
Type 3R remote display kit
configure the overload
without opening the
Mounting plate adapter
enclosure door

1.2
1

Type 3R kit mounts with
standard 30 mm holes
Mounting plate for retrofit
in existing installations

Type 3R Kit with Remote Display Mounted Inside
Description

Catalog
Number

C4411

Remote display Types 1 and 12 (UL 508)

C4411

C4413

Type 3R kit for remote display (UL 508)

C4413

Conversion plate (not shown)

C441CMP1

Communication Cables
The Remote Display requires
a communication cable to
connect to the Motor Insight
overload relay:

Communication Cable
Lengths
Length in
Inches (meters)

Catalog
Number

9.8 (0.25)

D77E-QPIP25

39.4 (1.0)

D77E-QPIP100

78.7 (2.0)

D77E-QPIP200

118.1 (3.0)

D77E-QPIP300

Current Transformer Kits
Description

Catalog
Number

Three 150:5 CTs to be used with Motor Insight

C441CTKIT150

Three 300:5 CTs to be used with Motor Insight

C441CTKIT300

Three 600:5 CTs to be used with Motor Insight

C441CTKIT600

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

47

1.2

C441 overload and monitoring relay
Technical data and specifications

1 Technical Data and Specifications
Motor Insight
Description

Specification
C441B_

C441C_

C441D_

C441_ _ _ _NOUI

Electrical Ratings
Feature

Range

Operating voltage (threephase) and frequency

170–264 Vac 50/60 Hz

323–528 Vac 50/60 Hz

489–660 Vac 50/60 Hz

170–660 Vac 50/60 Hz

Selectable

Selectable

Selectable

Selectable

C441_A and
C4410109NOUI

1–9A

C441_B and
C4410590NOUI

5–90A

Up to 540A with external CTs
Refer to Page 42 for CT
multiplier and wire wrap
schedule.

Trip Class
5–30
FLA Range
Up to 540A with external CTs
Refer to Page 42 for CT
multiplier and wire wrap
schedule.

Up to 540A with external CTs
Refer to Page 42 for CT
multiplier and wire wrap
schedule.

Monitoring Capabilities
Feature

Value

Current

Per phase rms (1A, 1B, 1C),
2% accuracy
Average rms, 2% accuracy
Imbalance percent (0–100%)
Ground fault current,
10% accuracy

Per phase rms (1A, 1B, 1C),
2% accuracy
Average rms, 2% accuracy
Imbalance percent (0–100%)
Ground fault current,
10% accuracy

Per phase rms (1A, 1B, 1C),
2% accuracy
Average rms, 2% accuracy
Imbalance percent (0–100%)
Ground fault current,
10% accuracy

Per phase rms (1A, 1B, 1C),
2% accuracy
Average rms, 2% accuracy
Imbalance percent (0–100%)
Ground fault current,
10% accuracy

Voltage

Per phase rms (1A, 1B, 1C),
2% accuracy
Average rms, 2% accuracy
Imbalance percent (0–100%)

Per phase rms (1A, 1B, 1C),
2% accuracy
Average rms, 2% accuracy
Imbalance percent (0–100%)

Per phase rms (1A, 1B, 1C),
2% accuracy
Average rms, 2% accuracy
Imbalance percent (0–100%)

Per phase rms (1A, 1B, 1C),
2% accuracy
Average rms, 2% accuracy
Imbalance percent (0–100%)

Power

Motor kW, 5% accuracy
Motor power factor,
inductive 0–1.0, 1% accuracy

Motor kW, 5% accuracy
Motor power factor,
inductive 0–1.0, 1% accuracy

Motor kW, 5% accuracy
Motor power factor,
inductive 0–1.0, 1% accuracy

Motor kW, 5% accuracy
Motor power factor,
inductive 0–1.0, 1% accuracy

Thermal capacity

0% cold, 100% trip

0% cold, 100% trip

0% cold, 100% trip

0% cold, 100% trip

Motor run hours

0–65,535 hours

0–65,535 hours

0–65,535 hours

0–65,535 hours

Frequency

47–63 Hz, 1% accuracy

47–63 Hz, 1% accuracy

47–63 Hz, 1% accuracy

47–63 Hz, 1% accuracy

Thermal overload setting

1.05 x FLA: Does not trip
1.15 x FLA: Overload trip

1.05 x FLA: Does not trip
1.15 x FLA: Overload trip

1.05 x FLA: Does not trip
1.15 x FLA: Overload trip

1.05 x FLA: Does not trip
1.15 x FLA: Overload trip

Feature

Range

Motor Protection

Fault Delay Setting

Jam

150–400% of motor FLA, OFF

150–400% of motor FLA, OFF

150–400% of motor FLA, OFF

50–400% of motor FLA, OFF

1–20 seconds

Current imbalance

1–30%, OFF

1–30%, OFF

1–30%, OFF

1–30%, OFF

1–20 seconds

Current phase loss

Fixed threshold 60%

Fixed threshold 60%

Fixed threshold 60%

Fixed threshold 60%

1–20 seconds

C441_A and
C4410109NOUI
1–9A

0.3–2.0A with one pass
through the CTs Ŀ

0.3–2.0A with one pass
through the CTs Ŀ

0.3–2.0A with one pass
through the CTs Ŀ

0.3–2.0A with one pass
through the CTs Ŀ

<150%, 1–60 seconds
>150%, 2 seconds
>250%, 1 second

C441_B and
C4410590NOUI
5–90A

3.0–20A with one pass
through the CTs Ŀ

3.0–20A with one pass
through the CTs Ŀ

3.0–20A with one pass
through the CTs Ŀ

3.0–20A with one pass
through the CTs Ŀ

<150%, 1–60 seconds
>150%, 2 seconds
>250%, 1 second

OFF = Ignore, 1 = ACB, 2 = ABC

OFF = Ignore, 1 = ACB, 2 = ABC

Ground fault current

Phase reversal

OFF = Ignore, 1 = ACB, 2 = ABC
minutes, auto ŀ

Fault reset delay

2–500

Fault reset attempts

0–4 restarts allowed or
automatic reset ŀ

OFF = Ignore, 1 = ACB, 2 = ABC
2–500 minutes, auto

ŀ

0–4 restarts allowed or
automatic reset ŀ

ŀ

2–500 minutes, auto ŀ

0–4 restarts allowed or
automatic reset ŀ

0–4 restarts allowed or
automatic reset ŀ

2–500 minutes, auto

Notes
Ŀ Lower levels are achievable with multiple passes.
ŀ Motor fault reset characteristics can be programmed as a group or for motor overloads only. Reference the user manual for more detailed information.

48

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

C441 overload and monitoring relay
Technical data and specifications

1.2

Motor Insight, continued
Description

Specification
C441B_

1
C441C_

C441D_

C441_ _ _ _NOUI

50–90% of motor FLA

50–90% of motor FLA

50–90% of motor FLA

Load Protection
Feature

Range

Under current

50–90% of motor FLA

Fault Delay Setting
1–60 seconds

Low power (kW)

20–80% of rated kW

20–80% of rated kW

20–80% of rated kW

20–80% of rated kW

1–60 seconds

High power (kW)

50–110% of rated kW

50–110% of rated kW

50–110% of rated kW

50–110% of rated kW

1–60 seconds

Load reset delay

2–500 minutes, auto

2–500 minutes, auto

2–500 minutes, auto

2–500 minutes, auto

Load reset attempts

0–4, auto

0–4, auto

0–4, auto

0–4, auto

Supply Protection
Feature

Range

Over voltage

170–264 Vac

323–528 Vac

489–660 Vac

0–660 Vac

Fault Delay Setting
1–20 seconds

Under voltage

170–264 Vac

323–528 Vac

489–660 Vac

0–660 Vac

1–20 seconds

Voltage imbalance

1–20% imbalance

1–20% imbalance

1–20% imbalance

1–20% imbalance

1–20% imbalance

Restart delay setting

1–500 seconds

1–500 seconds

1–500 seconds

1–500 seconds

1–500 seconds

Radiated emissions
IEC 60947-4-1—Table 15,
EN 55011 (CISPIR 11)
Group 1, Class A

30–1000 mHz

30–1000 mHz

30–1000 mHz

30–1000 mHz

30–1000 mHz

Conducted emissions
IEC 60947-4-1—Table 14,
EN 55011 (CISPIR 11)
Group 1, Class A

0.15–30 mHz

0.15–30 mHz

0.15–30 mHz

0.15–30 mHz

0.15–30 mHz

ESD immunity
IEC 60947-4-1 (Table 13)

±8 kV air, ±4 kV contact

±8 kV air, ±4 kV contact

±8 kV air, ±4 kV contact

±8 kV air, ±4 kV contact

±8 kV air, ±4 kV contact

Radiated immunity
IEC 60947-4-1

10 V/m 80–1000 mHz
80% amplitude modulated
1 kHz sine wave

10 V/m 80–1000 mHz
80% amplitude modulated
1 kHz sine wave

10 V/m 80–1000 mHz
80% amplitude modulated
1 kHz sine wave

10 V/m 80–1000 mHz
80% amplitude modulated
1 kHz sine wave

10 V/m 80–1000 mHz
80% amplitude modulated
1 kHz sine wave

Conducted immunity
IEC 60947-4-1

140 dBuV (10V rms)
150 kHz–80 mHz

140 dBuV (10V rms)
150 kHz–80 mHz

140 dBuV (10V rms)
150 kHz–80 mHz

140 dBuV (10V rms)
150 kHz–80 mHz

140 dBuV (10V rms)
150 kHz–80 mHz

Fast transient immunity
IEC 60947-4-1 (Table 13)
IEC 61000-4-4

±2 kV using direct method

±2 kV using direct method

±2 kV using direct method

±2 kV using direct method

±2 kV using direct method

Surge immunity
IEC 60947-4-1 (Table 13)
IEC 61000-4-4

Three-phase power inputs:
±2 kV line-to-line (DM)
±4 kV line-to-ground (CM)

Three-phase power inputs:
±2 kV line-to-line (DM)
±4 kV line-to-ground (CM)

Three-phase power inputs:
±2 kV line-to-line (DM)
±4 kV line-to-ground (CM)

Three-phase power inputs:
±2 kV line-to-line (DM)
±4 kV line-to-ground (CM)

Three-phase power inputs:
±2 kV line-to-line (DM)
±4 kV line-to-ground (CM)

IEC 61000-4-5 Class 3 User IO
and communication lines:
±1 kV line-to-line (DM)
±2 kV line-to-ground (CM)

IEC 61000-4-5 Class 3 User IO
and communication lines:
±1 kV line-to-line (DM)
±2 kV line-to-ground (CM)

IEC 61000-4-5 Class 3 User IO
and communication lines:
±1 kV line-to-line (DM)
±2 kV line-to-ground (CM)

IEC 61000-4-5 Class 3 User IO
and communication lines:
±1 kV line-to-line (DM)
±2 kV line-to-ground (CM)

IEC 61000-4-5 Class 3 User IO
and communication lines:
±1 kV line-to-line (DM)
±2 kV line-to-ground (CM)

Voltage variations
immunity
IEC 60947-4-1

30% dip, at 100 ms
60% dip at 10 ms
>95% interrupt at 5 ms

30% dip, at 100 ms
60% dip at 10 ms
>95% interrupt at 5 ms

30% dip, at 100 ms
60% dip at 10 ms
>95% interrupt at 5 ms

30% dip, at 100 ms
60% dip at 10 ms
>95% interrupt at 5 ms

30% dip, at 100 ms
60% dip at 10 ms
>95% interrupt at 5 ms

Electromagnetic field
IEC 60947-4-1 (Table 13)
IEC 61000-4-3

10 V/m

10 V/m

10 V/m

10 V/m

10 V/m

Ground fault

UL 508, UL 1053
Sections 21 and 27

UL 508, UL 1053
Sections 21 and 27

UL 508, UL 1053
Sections 21 and 27

UL 508, UL 1053
Sections 21 and 27

UL 508, UL 1053
Sections 21 and 27

Electrical/EMC

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

49

1.2

C441 overload and monitoring relay
Technical data and specifications

1 Motor Insight, continued
Specification
C441B_

Description

C441C_

C441D_

C441_ _ _ _NOUI

Environmental Ratings
Feature

Range

Ambient temperature (operating)

–4° to 122°F (–20° to 50°C)

–4° to 122°F (–20° to 50°C)

–4° to 122°F (–20° to 50°C)

–4° to 122°F (–20° to 50°C)

Ambient temperature (storage)

–40° to 85°C

–40° to 85°C

–40° to 85°C

–40° to 85°C

Operating humidity

5% to 95% noncondensing

5% to 95% noncondensing

5% to 95% noncondensing

5% to 95% noncondensing

Altitude (no derating)

2000m

2000m

2000m

2000m

Shock (IEC 60068-2-27)

15G any direction

15G any direction

15G any direction

15G any direction

Vibration (IEC 60068-2-6)

3G any direction

3G any direction

3G any direction

3G any direction

Pollution degree per IEC 60947-1

3

3

3

3

Ingress protection

IP20

IP20

IP20

IP20

Capacity
Input, auxiliary contact and external reset terminals
Terminal capacity

18–12 AWG

18–12 AWG

18–12 AWG

18–12 AWG

Tightening torque

5.3 lb-in (0.6 Nm)

5.3 lb-in (0.6 Nm)

5.3 lb-in (0.6 Nm)

5.3 lb-in (0.6 Nm)

Voltages
Monitoring voltage

170–264 Vac 50/60Hz

323–528 Vac 50/60Hz

489–660 Vac 60Hz

0–660 Vac 50/60Hz

Insulation voltage Ui (three-phase voltage)

600 Vac

600 Vac

600 Vac

600 Vac

Insulation voltage Ui (control)

240 Vac

240 Vac

240 Vac

240 Vac

Impulse withstand Uimp
(main/control)

6 kV

6 kV

6 kV

6 kV

10 years

10 years

10 years

10 years

B300 pilot duty
5A thermal continuous current
30A make 3.00A break
at 120 Vac and
15A make 1.50A break
at 240 Vac

B300 pilot duty
5A thermal continuous current
30A make 3.00A break
at 120 Vac and
15A make 1.50A break
at 240 Vac

B300 pilot duty
5A thermal continuous current
30A make 3.00A break
at 120 Vac and
15A make 1.50A break
at 240 Vac

B300 pilot duty
5A thermal continuous current
30A make 3.00A break
at 120 Vac and
30A make 1.50A break
at 240 Vac Ŀ

Isolated 120 Vac digital input
IEC 61131-2 Section 5 Type 1

Isolated 120 Vac digital input
IEC 61131-2 Section 5 Type 1

Isolated 120 Vac digital input
IEC 61131-2 Section 5 Type 1

Isolated 120 Vac digital input
IEC 61131-2 Section 5 Type 1

Trip

Fault

Fault

Fault

Fault

Reset

Ready

Ready

Ready

Ready

Autoreset

Trip faulted/Ready flashing

Trip faulted/Ready flashing

Trip faulted/Ready flashing

Trip faulted/Ready flashing

5W

5W

5W

5W

Expected Life
Mechanical/electrical
Output Contact Ratings
Two output relays
One Form C SPDT (fault relay)
One Form A SPST (ground fault relay)
C441_ _ _ _NOUI models:
One Form A SPST
One Form B SPST
External remote reset terminal
Indications

Power Consumption
Maximum
Options
Remote display

Type 1, 12 and Type 3R kit

Type 1, 12 and Type 3R kit

Type 1, 12 and Type 3R kit

Type 1, 12 and Type 3R kit

Communications modules

Modbus, DeviceNet and
PROFIBUS with I/O

Modbus, DeviceNet and
PROFIBUS with I/O

Modbus, DeviceNet and
PROFIBUS with I/O

Modbus, DeviceNet and
PROFIBUS with I/O

Note
Ŀ In this model, there are two isolated relays: one Form A and one Form B SPST. One is the fault relay, and one is a programmable auxiliary relay.

50

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.2

C441 overload and monitoring relay
Technical data and specifications

Motor Insight Short Circuit Ratings (North America CSA and UL)

1

Standard-Fault Short Circuit Data
Overload
FLA Range

Maximum
Operating
Voltage

Withstand
Rating

Maximum
Fuse (RK5)

Maximum
Thermal-Magnetic
Circuit Breaker

1–9A

264 Vac

5000A at 240 Vac

35A

35A

1–9A

1–9A

528 Vac

660 Vac

5000A at 480 Vac

5000A at 600 Vac

35A

35A

35A

35A

Maximum
Withstand
Rating

Maximum
Fuse (RK5)

Eaton
Thermal-Magnetic
Circuit Breaker

Catalog
Number
C441BA

100 kA at 240 Vac

35A

—

100 kA at 240 Vac

—

FDC3035L

100 kA at 480 Vac

35A

—

100 kA at 480 Vac

—

FDC3035L

100 kA at 600 Vac

35A

—

35 kA at 600 Vac

—

FDC3035L

35A
—
35A
—
35A
—

—
FDC3035L
—
FDC3035L
—
FDC3035L

C4410109NOUI

C441BB

1–9A

660 Vac

5000A at 600 Vac

35A

35A

100 kA at 240 Vac
100 kA at 240 Vac
100 kA at 480 Vac
100 kA at 480 Vac
100 kA at 600 Vac
35 kA at 600 Vac

5–90A

264 Vac

10,000A at 240 Vac

350A

350A

100 kA at 240 Vac

350A

—

100 kA at 240 Vac

—

KDC3350

5–90A

5–90A

5–90A

528 Vac

660 Vac

660 Vac

10,000A at 480 Vac

10,000A at 600 Vac

10,000A at 600 Vac

350A

350A

350A

350A

350A

350A

C441CA

100 kA at 480 Vac

350A

—

100 kA at 480 Vac

—

KDC3350

100 kA at 600 Vac

350A

—

65 kA at 600 Vac

—

KDC3350

100 kA at 240 Vac
100 kA at 240 Vac
100 kA at 480 Vac
100 kA at 480 Vac
100 kA at 600 Vac
35 kA at 600 Vac

350A
—
350A
—
350A
—

—
KDC3350
—
KDC3350
—
KDC3350

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

C441DA

C441CB

C441DB

C4410590NOUI

51

1.2

C441 overload and monitoring relay
Technical data and specifications

1 Line Powered Models
Terminal Connection Diagram
18–12 AWG; Torque 5.3 lb-in/0.6 Nm
B300 Pilot Duty Only

Use 75C CU wire only

120 Vac
NC
L1

Ŀ

L2

Ŀ

L3

95

Ŀ

NO
96

97

GF Shunt
98

15

16

Reset
R1

R2

For C441BA, BB, CA, CB, DA and DB

Terminal Connection Specifications
Name

Designation

Input

Description

Line voltage

L1, L2, L3

Line voltage

Three-phase line voltage input
L1, L2, L3 connections must correspond to the respective CT1, CT2, CT3 current leads

Fault relay

95/96
96/97 (common)
97/98

B300 UL 508

Form C contact:
95/96 Contact opens when the unit is faulted or unpowered
97/98 Contact closes when the unit is faulted or unpowered

GF shunt

15
16

B300 UL 508

Form A contact:
Contact closes when a ground fault is active

Reset input

R1, R2

120 Vac

Fault reset input IEC 61131-2 Type 1

Control Powered Models
Terminal Connection Diagram
120 Vac
NC
L1

L2

L3

95

NO
96

97

Cntrl. Pwr.
98

X1

X2

120 Vac
Reset
R1

R2

For C4410109NOUI and C441059NOUI

Terminal Connection Specifications
Name

Designation

Input

Description

Line voltage

L1, L2, L3

Line voltage

Three-phase line voltage input
L1, L2, L3 connections must correspond to the respective CT1, CT2, CT3 current leads
Terminal provided for wiring control power transformer (9A maximum capacity)

Control power

X1, X2

110–120 Vac
Control power option for C441_ _ _ _NOUI
50–60Hz (+10/–15%)

Fault relay
95/96
For C441_ _ _ _NOUI, the fault relay and auxiliary relay are 96/97 (isolated)
isolated and do not share a common. By default they will
97/98
behave like a Form C, but they can be programmed to act
independently from one another.

B300 UL 508

Form C contact:
95/96 Contact opens when the unit is faulted or unpowered
97/98 Contact closes when the unit is faulted or unpowered
Can be programmed to act independently of the 95/96 only in the C441_ _ _ _NOUI models

GF shunt
This relay does not exist on the C441_ _ _ _NOUI models.
Instead, this functionality is available in the fully
programmable 97/98 auxiliary relay.

97/98

B300 UL 508

Form A contact:
Contact closes when a ground fault is active
Separate GF control can still be achieved by programming auxiliary relay 97/98 to act
independently of the 95/96 relay

Reset input

R1, R2

120 Vac

Fault reset input IEC 61131-2 Type 1

Note
Ŀ No motor loads, 9A maximum.

52

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

C441 overload and monitoring relay
Technical data and specifications

1.2

Modbus Communication Modules
Description

1
Specification

Electrical/EMC
Radiated emissions
IEC 60947-4-1—Table 15, EN 55011 (CISPIR 11) Group 1, Class A

30–1000 mHz

Conducted emissions
IEC 60947-4-1—Table 14, EN 55011 (CISPIR 11) Group 1, Class A

0.15–30 mHz

ESD immunity
IEC 60947-4-1 (Table 13) IEC 61000-4-2

±8 kV air, ±4 kV contact

Radiated immunity
IEC 60947-4-1

10 V/m 80–1000 mHz
80% amplitude modulated 1 kHz sine wave

Conducted immunity
IEC 60947-4-1

140 dBuV (10V rms)
150 kHz–80 mHz

Fast transient immunity
IEC 60947-4-1 (Table 13) IEC 61000-4-4

±2 kV using direct method

Surge immunity
IEC 60947-4-1 (Table 13)
IEC 61000-4-5 Class 3

User IO and communication lines Ŀ :
±1 kV line-to-line (DM)
±2 kV line-to-ground (CM)

Electromagnetic field 1
IEC 60947-4-1 (Table 13) IEC 61000-4-3

10 V/m

Environmental Ratings
Ambient temperature (operating)

–20° to 50°C

Ambient temperature (storage)

–40° to 85°C

Operating humidity

5 to 95% noncondensing

Altitude (no derating)

2000m

Shock (IEC 60068-2-27)

15G any direction

Vibration (IEC 60068-2-6)

3G any direction

Pollution degree per IEC 60947-1

3

Degree of protection

IP20

Over voltage category per UL 508

III

C441P 24 Vdc Input
Nominal input voltage

24 Vdc

Operating voltage

18–30 Vdc

Number of inputs

4

Signal delay

5 ms (programmable to 65 sec)

OFF-state voltage

< 6 Vdc

ON-state voltage

> 18 Vdc

Nominal input current

5 mA

Isolation

1500V

Terminal screw torque

7–9 in-lb

24 Vdc source current

50 mA

Operating Voltage Range—DC Input Modules
OFF State

Transition Region

ON State

0–6 Vdc

6–18 Vdc

18–30 Vdc

C441N 120 Vac Input
Nominal input voltage

120 Vac

Operating voltage

80–140 Vac

Number of inputs

4

OFF-state voltage

< 30 Vac

ON-state voltage

> 80 Vac

Nominal input current

15 mA

Signal delay

1/2 cycle

Isolation

1500V

Terminal screw torque

7–9 in-lb

Note
Ŀ Relates to C441M only.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

53

1.2

C441 overload and monitoring relay
Technical data and specifications

1 Modbus Communication Modules, continued
Description

Specification

Operating Voltage Range—AC Input Modules
OFF State

Transition Region

ON State

0–30 Vac

30–80 Vac

80–140 Vac

Output Modules
Nominal voltage

120 Vac
24 Vdc

Number of outputs

(2) 1NO Form A
1NO/NC Form C

Relay OFF time

3 ms

Relay ON time

7 ms

Max. current per point Ŀ

5A (B300 rated)

Electrical life

100,000 cycles

Mechanical life

1,000,000 cycles

DeviceNet Communication Modules
Description

Specification

Electrical/EMC
Radiated emissions
IEC 60947-4-1—Table 15, EN 55011
(CISPIR 11) Group 1, Class A

30–1000 mHz

Conducted emissions
IEC 60947-4-1—Table 14, EN 55011
(CISPIR 11) Group 1, Class A

0.15–30 mHz

ESD immunity
IEC 60947-4-1 (Table 13) IEC 61000-4-2

±8 kV air, ±4 kV contact

Radiated immunity
IEC 60947-4-1

10 V/m 80–1000 mHz
80% amplitude modulated 1 kHz sine wave

Conducted immunity
IEC 60947-4-1

140 dBuV (10V rms)
150 kHz–80 mHz

Fast transient immunity
IEC 60947-4-1 (Table 13) IEC 61000-4-4

±2 kV using direct method

Surge immunity
IEC 60947-4-1 (Table 13)
IEC 61000-4-5 Class 2

User IO and communication lines:
±1 kV line-to-line (DM)
±2 kV line-to-ground (CM)

Electromagnetic field
IEC 60947-4-1 Table 13, IEC 61000-4-3

10 V/m

Environmental Ratings
Ambient temperature (operating)

–20° to 50°C

Ambient temperature (storage)

–40° to 85°C

Operating humidity

5–95% noncondensing

Altitude (no derating)

2000m

Shock (IEC 60068-2-27)

15G any direction

Vibration (IEC 60068-2-6)

3G any direction

Pollution degree per IEC 60947-1

3

Degree of protection

IP20

DeviceNet
DeviceNet connections

Group 2, polling, bit strobe, explicit, no UCMM

DeviceNet baud rate

125K, 250K, 500K

Note
Ŀ Resistive current at 55°C ambient.

54

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

C441 overload and monitoring relay
Technical data and specifications

1.2

DeviceNet Communication Modules, continued
Description

1

Specification

C441L 24 Vdc Input
Nominal input voltage

24 Vdc

Operating voltage

18–30 Vdc

Number of inputs

4

Signal delay

5 ms (programmable to 65 sec)

OFF-state voltage

< 6 Vdc

ON-state voltage

> 18 Vdc

Nominal input current

5 mA

Isolation

250V

Terminal screw torque

7–9 in-lb

24V source current

50 mA

Operating Voltage Range—DC Input Modules
OFF State

Transition Region

ON State

0–6 Vdc

6–18 Vdc

18–30 Vdc

C441K 120 Vac Input
Nominal input voltage

120 Vac

Operating voltage

80–140 Vac

Number of inputs

4

OFF-state voltage

< 30 Vac

ON-state voltage

> 80 Vac

Nominal input current

15 mA

Signal delay

1/2 cycle

Isolation

250V

Terminal screw torque

7–9 in-lb

Operating Voltage Range—AC Input Modules
OFF State

Transition Region

ON State

0–30 Vac

30–80 Vac

80–140 Vac

Output Modules
Nominal voltage

120 Vac
24 Vdc

Number of outputs

(2) 1NO Form A
1NO/NC Form C

Relay OFF time

3 ms

Relay ON time

7 ms

Max. current per point Ŀ

5A (B300 rated)

Electrical life

100,000 cycles

Mechanical life

1,000,000 cycles

Note
Ŀ Resistive current at 55°C ambient.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

55

1.2

C441 overload and monitoring relay
Technical data and specifications

1 PROFIBUS Communication Modules
Description

Specification

Electrical/EMC
Radiated emissions
IEC 60947-4-1—Table 15, EN 55011
(CISPIR 11) Group 1, Class A

30–1000 mHz

Conducted emissions
IEC 60947-4-1—Table 14, EN 55011
(CISPIR 11) Group 1, Class A

0.15–30 mHz

ESD immunity
IEC 60947-4-1 (Table 13) IEC 61000-4-2

±8 kV air, ±4 kV contact

Radiated immunity
IEC 60947-4-1 Table 13, IEC 61000-4-3

10 V/m 80–1000 mHz
80% amplitude modulated 1 kHz sine wave

Conducted immunity
IEC 60947-4-1

140 dBuV (10V rms)
150 kHz–80 mHz

Fast transient immunity
IEC 60947-4-1 (Table 13) IEC 61000-4-4

±2 kV using direct method

Surge immunity
IEC 60947-4-1 (Table 13)
IEC 61000-4-5 Class 2

User IO and communication lines:
±1 kV line-to-line (DM)
±2 kV line-to-ground (CM)

Environmental Ratings
Ambient temperature (operating)

–20° to 50°C

Ambient temperature (storage)

–40° to 85°C

Operating humidity

5–95% noncondensing

Altitude (no derating)

2000m

Shock (IEC 60068-2-27)

15G any direction

Vibration (IEC 60068-2-6)

3G any direction

Pollution degree per IEC 60947-1

3

Degree of protection

IP20

PROFIBUS
PROFIBUS connections

Group 2, polling, bit strobe, explicit, no UCMM

PROFIBUS baud rate

9.6K, 19.2K, 45.45K, 93.75K, 187.5K, 500K, 1.5M, 3M, 6M, 12M

C441Q 24 Vdc Input
Nominal input voltage

24 Vdc

Operating voltage

18–30 Vdc

Number of inputs

4

Signal delay

5 ms (programmable to 65 sec)

OFF-state voltage

<6 Vdc

ON-state voltage

>10 Vdc

Nominal input current

5 mA

Isolation

1500V

Terminal screw torque

7–9 in-lb

24V source current

50 mA

56

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

C441 overload and monitoring relay
Technical data and specifications

1.2

PROFIBUS Communication Modules, continued
Description

1

Specification

Operating Voltage Range—DC Input Modules
OFF State

Transition Region

ON State

0–6 Vdc

6–18 Vdc

18–30 Vdc

C441S 120 Vac Input
Nominal input voltage

120 Vac

Operating voltage

80–140 Vac

Number of inputs

4

OFF-state voltage

< 20 Vac

ON-state voltage

> 70 Vac

Nominal input current

15 mA

Signal delay

1/2 cycle

Isolation

1500V

Terminal screw torque

7–9 in-lb

Operating Voltage Range—AC Input Modules
OFF State

Transition Region

ON State

0–30 Vac

30–80 Vac

80–140 Vac

Output Modules
Nominal voltage

120 Vac
24 Vdc

Number of outputs

(2) 1NO Form A
1NO/NC Form C

Relay OFF time

3 ms

Relay ON time

7 ms

Max. current per point Ŀ

5A (B300 rated)

Electrical life

100,000 cycles

Mechanical life

1,000,000 cycles

Note
Ŀ Resistive current at 55°C ambient.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

57

1.2

C441 overload and monitoring relay
Technical data and specifications

1 Ethernet (Modbus TCP / EtherNet/IP) Communication Modules
Description

Specification

Electrical/EMC
Radiated emissions
IEC 60947-4-1, Table 15, EN 55011
(CISPIR 11) Group 1, Class A

30–1000 mHz

Conducted emissions
IEC 60947-4-1, Table 15, EN 55011
(CISPIR 11) Group 1, Class A

0.15–30 mHz

ESD immunity
IEC 60947-4-1 (Table 13) IEC 61000-4-2

±8 kV air, ±4 kV contact

Radiated immunity
IEC 60947-4-1 (Table 13) IEC 61000-4-3

10 V/m 80–1000 mHz
80% amplitude modulated 1 kHz sine wave

Conducted immunity
IEC 60947-4-1

140 dBuV (10V rms)
150 kHz to 80 mHz

Fast transient immunity
IEC 60947-4-1 (Table 13) IEC 61000-4-4

±2 kV using direct method

Surge immunity
IEC 60947-4-1 (Table 13)
IEC 61000-4-5 Class 2

User IO and communication lines:
±1 kV line-to-line (DM)
±2 kV line-to-ground (CM)

Environmental Ratings
Ambient temperature (operating)

–20° to 50°C

Ambient temperature (storage)

–40° to 85°C

Operating humidity

5–95% noncondensing

Altitude (no derating)

2000m

Shock (IEC 60068-2-27)

15G any direction

Vibration (IEC 60068-2-6)

3G any direction

Pollution degree per IEC 60947-1

3

Degree of protection

IP20

Ethernet
Ethernet connections

Integrated two-port switch with dual
RJ45 Ethernet connections

Ethernet type

Ethernet 10/100 Mbs, AutoMDX,
Auto Negotiation

C441T 24 Vdc Input
Nominal input voltage

24 Vdc

Operating voltage

18–30 Vdc

Number of inputs

4

Signal delay

5 ms (programmable to 65 sec)

OFF-state voltage

<6 Vdc

ON-state voltage

>18 Vdc

Nominal input current

5 mA

Isolation

1500V

Terminal screw torque

7–9 in-lb

24V source current

50 mA

58

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

C441 overload and monitoring relay
Technical data and specifications

1.2

Ethernet (Modbus TCP / EtherNet/IP) Communication Modules, continued
Description

1

Specification

Operating Voltage Range—DC Input Modules
OFF State

Transition Region

ON State

0–6 Vdc

6–18 Vdc

18–30 Vdc

C441R 120 Vac Input
Nominal input voltage

120 Vac

Operating voltage

80–140 Vac

Number of inputs

4

OFF-state voltage

< 30 Vac

ON-state voltage

> 80 Vac

Nominal input current

15 mA

Signal delay

1/2 cycle

Isolation

1500V

Terminal screw torque

7–9 in-lb

Operating Voltage Range—AC Input Modules
OFF State

Transition Region

ON State

0–30 Vac

30–80 Vac

80–140 Vac

Nominal voltage

120 Vac
24 Vdc

Number of outputs

(2) 1NO Form A
1NO/NC Form C

Relay OFF time

3 ms

Relay ON time

7 ms

Maximum current per point Ŀ

5A (B300 rated)

Electrical life

100,000 cycles

Mechanical life

1,000,000 cycles

Note
Ŀ Resistive current at 55°C ambient.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

59

1.2

C441 overload and monitoring relay
Dimensions

1 Dimensions
Approximate Dimensions in mm
Motor Insight Overload Relay
Terminal Ref.
97.0

84.1
5.1
4 Places

100.1

100.1

88.9

100.1
Mounting Dimension
(4) 10-32

Dia.
17.5
3 Places

101.1

125.0

Motor Insight with Mounted DeviceNet, PROFIBUS or Modbus with I/O Communication Module
5.1

Terminal Ref.
97.0

84.1

100.1

88.9

100.1

100.1

83.1

Mounting Dimensions
(4) 10-32
122.9

125.0
Dia.
17.5
3 Places

101.1
16.0

60

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

C441 overload and monitoring relay
Dimensions

1.2

Approximate Dimensions in mm
Motor Insight with Mounted Modbus Communication Module
5.1
4 Places

1

Terminal Ref.
97.0

84.1

48.0

88.9

100.1

100.1

100.1
Mounting Dimensions
(4) 10-32

125.0

115.1

125.0

15.0

Dia.

101.1

17.5
3 Places

Motor Insight Remote Display
2X ø 31.0
Hole in Panel

68.6
30.5

27.9

44.5

12 GA Max.
Panel Thickness

116.8

99.1

25.4

15.2

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

61

1.2

C441 overload and monitoring relay
Dimensions

1 Approximate Dimensions in mm
Motor Insight Cover Assembly
44.5

33.0

111.8

35.6

Motor Insight
50.8

106.7

109.2

25.4

35.6

Motor Insight Conversion Plate
7.6
99.1

5.1

10.2
5.1

101.6

91.4
68.6

58.4

78.7

5.1

83.8

62

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1

PKZ and PKE motor-protective
circuit-breakers
Machinery and installation downtimes should be kept as short as possible. The PKZ
fuseless motor-protective circuit-breakers combine short-circuit and overload protection
in one device, allowing fast restart readiness. PKZM01, PKZM0, PKZM4 and PKE have
the same accessories. Combines easily with DILM contactors and DS7 soft starters.
Connecting PKE to SmartWire-DT® facilitates high data transparency.
PKZM01 (up to 16 A) motor-protective circuit-breaker with pushbuttons

ATEX

• Motor-protective circuit-breaker in housing for protection types IP40 and IP65.
• Integrated EMERGENCY STOP and EMERGENCY OFF pushbuttons reduce wiring.
PKZM0 (up to 32 A) and PKZM4 (up to 65 A) motor-protective circuit-breakers with rotary handle
•
•
•
•

Short-circuit proof up to at least 50 kA for easy engineering
Trip-indicating auxiliary contact enables remote diagnosis
High safety through application as main switch or repair and maintenance switch
ATEX approval for protection of EEx e motors up to 65 A

PKE (up to 65 A) motor-protective circuit-breakers with electronic wide-range overload protection
•
•
•
•
•
•

High flexibility through plug-in trip block
Wide current setting ranges enable only five trip blocks up to 65 A
Precise and extremely long-term stable characteristic curves
Individual supply through integrated current converter
ATEX approval for protection of EEx e motors up to 65 A
Adjustable tripping classes

DC string circuit-breakers PKZ-SOL and DC switch-disconnectors P-SOL (up to 63 A) for
installations
•
•
•
•
•

High string circuit-breaker flexibility due to wide current setting range
Enclosed switch-disconnector for external mounting (IP65)
Remote shutdown through optional secondary voltage and shunt trip
Voltage up to 1000 V DC
TÜV certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Motor-protective circuit-breakers
Contents

Motor-protective circuit-breaker
PKZM01, PKZM0,PKZM4, PKE

System overview
PKZM01, PKZM0, PKZM4, PKE motor-protective circuit-breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
2

Ordering
Motor-protective circuit-breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Motor-protective circuit-breakers for startercombinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Transformer-protective circuit-breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
PKE electronic motor-protective circuit-breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Standard auxiliary contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Auxiliary contacts, shunt releases, undervoltage release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Engineering
Accessories for motor-protective circuit-breakers in enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Ordering
Insulated enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Busbar adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor feeder plugs, three-phase commoning links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Actuating voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16
20
22
25
26
29

Engineering
Motor-protective circuit-breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Characteristic curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Switching capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Technical data
Motor-protective circuit-breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Auxiliary contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Dimensions
PKZM01, PKZM0 motor-protective circuit-breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PKZM4 motor-protective circuit-breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DC string circuit-breaker PKZ-SOL,
DC switch-disconnectors P-SOL, SOL

39
40
45
46

Description
DC switches P-SOL, PKZ-SOL, SOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Ordering
DC switch-disconnector SOL, ready-to-install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
DC switch-disconnector P-SOL, open . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
DC string circuit-breaker PKZ-SOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Engineering
Circuit P-SOL, PKZ-SOL Interior circuit SOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Characteristic curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Technical data
DC switch-disconnectors P-SOL,SOL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
DC string circuit-breaker PKZ-SOL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Dimensions
DC switches P-SOL, PKZ-SOL, SOL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1

1.3
1

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Motor-protective circuit-breaker

System overview
1
8

6

7

7

7
3
2

5
4
7

3

5

7

Basic devices

Add-on functions

Motor-protective circuitbreaker PKZM01
Page 3
Motor-protective circuitbreaker PKZM0
Page 4

2

1

2

Motor-protective circuitbreakerwith wide-range
overload protection

3

7

Page 10

Page 8
Motor-protective circuitbreaker PKZM4
Page 4

Standard auxiliary contacts

Mounting accessories

4

Door coupling handles IP65
Page 20

Shunt release

6

Insulated enclosure

Page 29
Current limiters

8

Page 16
Mounting/wiring

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Page 12

Page 22

5

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE

1.3

Ordering

1

PKZM01
Screw terminals
Max. motor rating
AC-3

L

I>
T

Rated
uninterrupted
current

Setting range
Overload
releases

Shortcircuit
releases

Std. pack

Information relevant for export to
North America

Motor-protective circuit-breakers, type “1”; and type “2” coordination
–
–
–
0.16
0.1…0.16
2.2
PKZM01-0.16
278475

1 off

Product Standards

–

PKZM01-0.25
278476

1 off

220 V
230 V
240 V
P

380 V
400 V
415 V
P

440 V

P

Iu

Ir

I rm

kW

kW

kW

A

A

A

0.06

0.06

0.25

0.16…0.25

3.5

Part no.
Article no.

Price
See price
list

0.06

0.09

0.12

0.4

0.25…0.4

5.6

PKZM01-0.4
278477

1 off

0.09

0.12

0.18

0.63

0.4…0.63

8.8

PKZM01-0.63
278478

1 off

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

0.12

0.25

0.25

1

0.63…1

14

PKZM01-1
278479

1 off

Suitable for

0.25

0.55

0.55

1.6

1…1.6

22

PKZM01-1.6
278480

1 off

See also

0.37

0.75

1.1

2.5

1.6…2.5

35

PKZM01-2.5
278481

1 off

0.75

1.5

1.5

4

2.5…4

56

PKZM01-4
278482

1 off

1.1

2.2

3

6.3

4…6.3

88

PKZM01-6.3
278483

1 off

2.2

4

4

10

6.3…10

140

PKZM01-10
278484

1 off

3

5.5

5.5

12

8…12

168

PKZM01-12
278485

1 off

4

7.5

9

16

10…16

224

PKZM01-16
283390

1 off

5.5

9

11

20

16…20

280

PKZM01-20
283383

1 off

5.5

12.5

12.5

25

20…25

350

PKZM01-25
288893

1 off

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

UL 508; CSA-C22.2
No.14; IEC609474-1; CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA
certified
Branch circuits, or
suitable for group
installations
Page 34

UL 508; CSA-C22.2
No.14; IEC/EN 609474-1; CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA
certified

Notes

6
5

3

3
Accessories
Page
3 Standard auxiliary contacts
10
5 Trip-indicating auxiliary contact
12
6 Shunt release, undervoltage release
29
Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.
Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height
AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

3

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Motor-protective circuit-breaker

PKZM0, PKZM4

1

Screw terminals

Circuit
diagrams

Max. motor rating
AC-3

Rated
uninterrupted
current

Setting range
Overload
releases

Short-circuit
releases

220 V
230 V
240 V
P

380 V
400 V
415 V
P

440 V

500 V

660 V
690 V

P

P

P

Iu

Ir

I rm

kW

kW

kW

kW

kW

A

A

A

Motor-protective circuit-breakers, type “1” and type “2”coordination 1)
–
–
–
–
0.06
0.16
0.1…0.16
2.2

L

I>

–

0.06

0.06

0.06

0.12

0.25

0.16…0.25

3.5

0.06

0.09

0.12

0.12

0.18

0.4

0.25…0.4

5.6

0.09

0.12

0.18

0.25

0.25

0.63

0.4…0.63

8.8

0.12

0.25

0.25

0.37

0.55

1

0.63…1

14

0.25

0.55

0.55

0.75

1.1

1.6

1…1.6

22

0.37

0.75

1.1

1.1

1.5

2.5

1.6…2.5

35

0.75

1.5

1.5

2.2

3

4

2.5…4

56

1.1

2.2

3

3

4

6.3

4…6.3

88

2.2

4

4

4

7.5

10

6.3…10

140

3

5.5

5.5

5.5

11

12

8…12

168

4

7.5

9

9

12.5

16

10…16

224

5.5

9

11

12.5

15

20

16…20

280

5.5

12.5

12.5

15

22

25

20…25

350

7.5

15

15

22

30

32

25…32

448

T

Motor-protective circuit-breakers, type “1” and type “2” coordination 1)
4
7.5
9
9
12.5
16
10…16
224
5.5

12.5

12.5

15

22

25

16…25

350

7.5

15

17.5

22

22

32

25…32

448

11

20

22

24

30

40

32…40

560

14

25

30

30

45

50

40…50

700

17

30

37

37

55

58

50…58

812

18.5

34

37

45

55

65

55…65

882

Circuit-breakers 2)
For line and cable protection
–
–
–
–

–

16

10…16

224

–

–

–

–

–

25

16…25

350

–

–

–

–

–

32

25…32

448

L

I>
T

4

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Part no.
Article no.

Price
See price
list

Screw terminals on feed
side, spring-loaded terminals
on output side
Part no.
Price
Article no.
See price
list

PKZM0-0.16
072730
PKZM0-0.25
072731
PKZM0-0.4
072732
PKZM0-0.63
072733
PKZM0-1
072734
PKZM0-1.6
072735
PKZM0-2.5
072736

PKZM0-0,16-SC
229828
PKZM0-0,25-SC
229829
PKZM0-0,4-SC
229830
PKZM0-0,63-SC
229831
PKZM0-1-SC
229832
PKZM0-1,6-SC
229833
PKZM0-2.5-SC
229834

PKZM0-4
072737
PKZM0-6.3
072738
PKZM0-10
072739
PKZM0-12
278486
PKZM0-16
046938

PKZM0-4-SC
229835
PKZM0-6,3-SC
229836
PKZM0-10-SC
229837
PKZM0-12-SC
278487
PKZM0-16-SC
229838

PKZM0-20
046988
PKZM0-25
046989
PKZM0-32
278489
PKZM4-16
222350
PKZM4-25
222352
PKZM4-32
222353
PKZM4-40
222354
PKZM4-50
222355
PKZM4-58
222394
PKZM4-63
222413

PKZM4-16-CB
132591
PKZM4-25-CB
132592
PKZM4-32-CB
132593

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Motor-protective circuit-breaker

1.3
1

Spring-loaded terminals

Part no.
Article no.

PKZM0-0,16-C
229669
PKZM0-0,25-C
229670
PKZM0-0,4-C
229671
PKZM0-0,63-C
229672
PKZM0-1-C
229673
PKZM0-1,6-C
229674
PKZM0-2.5-C
229675

Price
See price
list

Std. pack

Notes

Information relevant for export to
North America

1 off

1)

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
6
5

See also

3

UL 508; CSA-C22.2 No.14;
IEC60947-4-1; CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA certified
Branch circuit: Manual type E if
used with terminal, or suitable
for group installations
Page 34

3

PKZM0-4-C
229676
PKZM0-6,3-C
229677
PKZM0-10-C
229678
PKZM0-12-C
278488
PKZM0-16-C
229679

Accessories
3 Standard auxiliary contacts
5 Trip-indicating auxiliary contact
6 Shunt release, undervoltage release

Page
10
12
29

Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.
Can be snap-fit to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height
PTB 02 ATEX 3151, see manual
21

1 off

Accessories
Page
3 Standard auxiliary contacts
10
5 Trip-indicating auxiliary contact
12
6 Shunt release, undervoltage release
29
Only motor-protective circuit-breaker:
Phase failure sensitivity to
IEC/EN 60947-4-1, VDE 0660 Part 102
Can be snap-fitted to IEC/EN 60715 top-hat rail
with 7.5 or 15 mm height
PTB 02 ATEX 3153,
21
see manual

6
5

3

3

1 off

Not usable as a main switch

2)

Product Standards
Phase failure sensitivity to
IEC/EN 60947-4-1, VDE 0660 Part 102.
Switching capacity of SCCR
65 kA (480 Y/277 V)
22 kA (600 Y/347 V)

NA Certification

UL 489; CSA-C22.2 No.5-09;
IEC 60947-4-1; CE marking
Request filed for UL and CSA

Specially designed for NA Yes
Feeder and branch circuit as BCPD
Suitable for

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

5

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Motor-protective circuit-breaker for starter combinations and transformers

PKZM0

1

Screw terminals
Max. motor rating

Rated
uninterrupted
current

AC-3

Motor-protective circuit-breakers
for starter combinations
Short-circuit protective breakers
without overload function

L

I>
T

Transformer-protective circuitbreakers

L

I>

Setting range

660 V
690 V

Iu

P

P

P

A

A

kW

kW

kW

–

–

–

0.06

0.16

2.2

PKM0-0,16
072720

1 off

–

0.06

0.06

0.06

0.12

0.25

3.5

1 off

0.06

0.09

0.12

0.12

0.18

0.4

5.6

0.09

0.12

0.18

0.25

0.25

0.63

8.8

0.12

0.25

0.25

0.38

0.55

1

14

0.25

0.37

0.55

0.75

1.1

1.6

22

0.37

0.75

1.1

1.1

1.5

2.5

35

0.75

1.5

1.5

2.2

3

4

56

PKM0-0,25
072721
PKM0-0,4
072722
PKM0-0,63
072723
PKM0-1
072724
PKM0-1,6
072725
PKM0-2.5
072726
PKM0-4
072727

1.1

2.2

3

3

4

6.3

88

1 off

2.2

4

4

4

7.5

10

140

3

5.5

5.5

5.5

11

12

168

4

7.5

9

9

12.5

16

224

5.5

9

11

12.5

15

20

280

5.5

12.5

12.5

15

22

25

350

7.5

15

15

22

30

32

448

–

–

–

–

–

0.16

0.1…0.16

2.4

–

–

–

–

–

0.25

0.16…0.25

4.25

–

–

–

–

–

0.4

0.25…0.4

6.8

–

–

–

–

–

0.63

0.4…0.63

12

–

–

–

–

–

1

0.63…1

20

–

–

–

–

–

1.6

1…1.6

32

–

–

–

–

–

2.5

1.6…2.5

50

–

–

–

–

–

4

2.5…4

84

–

–

–

–

–

6.3

4…6.3

141

–

–

–

–

–

10

6.3…10

224

–

–

–

–

–

12

8…12

224

–

–

–

–

–

16

10…16

280

PKM0-6,3
072728
PKM0-10
072729
PKM0-12
278490
PKM0-16
044502
PKM0-20
203594
PKM0-25
044503
PKM0-32
278491
PKZM0-0,16-T
088907
PKZM0-0,25-T
088908
PKZM0-0,4-T
088909
PKZM0-0,63-T
088910
PKZM0-1-T
088911
PKZM0-1,6-T
088912
PKZM0-2.5-T
088913
PKZM0-4-T
088914
PKZM0-6,3-T
088915
PKZM0-10-T
088916
PKZM0-12-T
278492
PKZM0-16-T
088917

–

–

–

–

–

20

16…20

350

1 off

–

–

–

–

–

25

20…25

437

PKZM0-20-T
088918
PKZM0-25-T
278493

kW

kW

–

440 V

T

6

Std.
pack

500 V

380 V
400 V
415 V
P

A

Price
See price
list

O v e r lo a d
releases
Ir

220 V
230 V
240 V
P

Short-circuit
releases
I rm

Part no.
Article no.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1 off
1 off
1 off
1 off
1 off
1 off

1 off
1 off
1 off
1 off
1 off
1 off
1 off
1 off
1 off
1 off
1 off
1 off
1 off
1 off
1 off
1 off
1 off
1 off

1 off

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Motor-protective circuit-breaker for starter combinations and transformers

1.3
1

Notes

When using the PKM0 as short-circuit protection for
motors with heavy starting duty, a device must be
selected whose rated operational current I e is higher
by the following factors:
CLASS 5 = 1.0
CLASS 10 = 1.0
CLASS 15 = 1.22
CLASS 20 = 1.41
CLASS 25 = 1.58
CLASS 30 = 1.73
CLASS 35 = 1.89
CLASS 40 = 2.0

6
5

3

3

Accessories
3 Standard auxiliary contacts
5 Trip-indicating auxiliary contact
6 Shunt release, undervoltage release
Additional accessories

Page
10
12
29
46

Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height
Assignment of the short-circuit protective breakers and contactors in “Fuseless motor-starter combinations” section.
An appropriate overload relay must be fitted to protect motors against overload.

6
5

3

3

Accessories
3 Standard auxiliary contacts
5 Trip-indicating auxiliary contact
6 Shunt release, undervoltage release

Page
10
12
29

For the protection of transformers with a high inrush current
Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height
Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

7

1.3
PKE
1
Motor rating

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Motor-protective circuit-breaker

Motor full-load current

Basic device

AC-3
220 V
230 V
240 V

380 V
400 V
415 V

440 V

500 V

660 V
690 V

P

I

I

I

I

I

kW

A

A

A

A

A

Motor-protective circuit-breakers, type“1” and type “2” coordination
0.06
0.37
–
–
0.09
0.54
0.31
–
0.12
0.72
0.41
0.37
0.18
1.04
0.6
0.54
0.25
–
0.8
0.76
0.37
–
1.1
1.02
0.55
–
–
–

–
–
0.33
0.48
0.7
0.9
–

–
–
–
0.35
0.5
0.7
0.9

0.75
0.18
0.25
0.37
0.55
0.75
1.1
1.5

–
1.04
1.4
2
2.7
3.2
–
–

–
–
–
1.1
1.5
1.9
2.6
3.6

–
–
–
1.02
1.39
1.68
2.41
3.28

–
–
–
–
1.2
1.5
2.1
2.9

1.1
–
–
–
–
1.1
1.5
2.1

2.2
3
0.75
1.1
1.5
2.2
3
4
5.5
7.5
2.2
3
4
5.5
7.5

–
–
3.2
4.6
6.3
8.7
11.5
–
–
–
8.7
11.5
14.8
19.6
26.4

–
–
–
–
3.6
5
6.6
8.5
11.3
–
–
–
8.5
11.3
15.2

–
–
–
–
3.3
4.6
6
7.7
10.2
–
–
–
–
10.2
13.8

4
–
–
–
–
4
5.3
6.8
9
–
–
–
–
9
12.1

2.9
3.8
–
–
–
–
3.8
4.9
6.5
8.8
–
–
–
–
8.8

11
15
18.5
22
30
5.5
7.5
11
15
18.5
22
30
37
45
55
2.2
3
4
5.5
7.5
11
15
18.5
22
30

–
–
–
–
–
19.6
26.4
38
51
63
–
–
–
–
–
8.7
11.5
14.8
19.6
26.4
–
–
–
–
–

21.7
29.3
–
–
–
–
–
21.7
29.3
36
41
55
–
–
–
–
–
8.5
11.3
15.2
21.7
29.3
–
–
–

19.8
26.6
–
–
–
–
–
19.7
26.6
32.9
37.4
50.3
61.4
–
–
–
–
–
10.2
13.8
19.8
26.6
–
–
–

17.4
23.4
28.9
–
–
–
–
17.4
23.4
28.9
33
44
54
65
–
–
–
–
9
12.1
17.4
23.4
28.9
–
–

12.6
17
20.9
23.8
32
–
–
–
17
20.9
23.8
32
39
47
58
–
–
–
–
8.8
12.6
17
20.9
23.8
32

Notes

8

Setting range
Overload releases

Part no.
Article no.

0.3…1.2 A

PKE12
121721

1off

1…4 A

PKE12
121721

1off

3…12 A

PKE12
121721

1off

8…32 A

PKE32
121722

1off

16…65 A

PKE65
138258

1off

Std. pack

Start of delivery
07/2010
8…32 A

Select switchgear and cables according to Class as shown in the table on Chapter 1.2 (Page 22)
1) For communications, module PKE-SWD-32 for contactors is required in addition,
See catalog
AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

See price
list

PKE65
138258

Start of delivery
07/2010

1off

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Motor-protective circuit-breaker

Trip module Expanded 1)

Trip module Standard

usable
for

Part no.
Article no.

PKE12

PKE-XTU-1,2
121723

See price
list

Std. pack

1off

usable
for

PKE12

Start of delivery
07/2010
PKE12

PKE-XTU-4
121724

Part no.
Article no.

See price
list

PKE-XTUA-1,2
121727

Std. pack

1off

Start of delivery
07/2010
1off

PKE12

Motor-protective circuitbreakers Standard
Complete device
Part no.
See price
Article no.
list

PKE12/XTU-1,2
121731

1.3
1
Std. pack

1off

Start of delivery
07/2010

PKE-XTUA-4
121728

1off

PKE12/XTU-4
121732

1off

1off

PKE12/XTU-12
121733

1off

1off

PKE32/XTU-32
121734

1off

1off

PKE65/XTU-65
138516

1off

Start of delivery
05/2010
PKE12
PKE32

PKE-XTU-12
121725

1off

PKE12
PKE32

PKE-XTUA-12
121729

Start of delivery
05/2010
PKE32

PKE-XTU-32
121726

1off

PKE32

PKE-XTUA-32
121730

Start of delivery
05/2010
PKE65

PKE-XTU-65
138259

1off

PKE65

Start of delivery
10/2010
PKE65

PKE-XTUW-32
138261

Start of delivery
10/2010
Information relevant for export to North America

PKE-XTUA-65
138260

Start of delivery
10/2010
1off

PKE65

Start of delivery
10/2010

PKE-XTUWA-32
138262

Start of delivery
10/2010
Product Standards
NA Certification

1off

PKE65/XTUW-32
138517

1 off

Start of delivery
10/2010
UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking
Request filed for UL and CSA

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

9

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Standard auxiliary contacts

NHI...-PKZ0...
Standard auxiliary contacts

1

For motor-protective circuit-breakers
Contact configuration
Contact sequence
N/O = normally
open contact

NC = normally
closed contact

1 N/O

1 NC

Circuit diagrams

Connection
method

1.13

1.21

Price

Std. pack

Screw
terminals

PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE 1)

NHI11-PKZ0
072896

5 off

Springloaded
terminals

PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE 1)

NHI11-PKZ0-C
229680

5 off

Screw
terminals

PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE 1)

NHI12-PKZ0
072895

5 off

Screw
terminals

PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE 1)

NHI21-PKZ0
072894

5 off

Screw
terminals

PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE 1)

NHI-E-11-PKZ0
082882

5 off

Screw
terminals

PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE 1)

NHI-E-10-PKZ0
082884

5 off

Springloaded
terminals

PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE 1)

NHI-E-10-PKZ0-C
229681

5 off

Springloaded
terminals

PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE 1)

NHI-E-01-PKZ0-C
229682

5 off

Screw
terminals

PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE 1)

NHI-B-11-PKZ0
208277

5 off

NHI11

I >

1 NC

1.14

1.22

1.13

1.21

1.14

1.22

L1L2L3
NHI11

I >

1 N/O

Part no.
Article no.

See price
list
L1L2L3

1 N/O

For use
with

2 NC

1.13 1.21 1.31
L1L2L3
NHI12

I>
1.14 1.22 1.32

2 N/O

1 NC

1.13 1.21 1.33
L1L2L3
NHI21

I >
1.14 1.22 1.34

1 N/O

1 NC

1.53 1.61
L1L2L3
NHI-E-11

I >
1.54 1.62

1 N/O

–

1.53
L1L2L3
NHI-E-10

I >
1.54

1 N/O

–

1.53
L1L2L3
NHI-E-10

I >
1.54

–

1 NC

1.51
L1L2L3
NHI-E-01

I>
1.52

1 N/O

1 NC

1.13

1.21

1.14

1.22

L1L2L3
NHI-B-11

I >

Notes

10

1)

Only standard auxiliary contacts manufactured on or after CW 36/2009 are for use with PKE.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Standard auxiliary contacts

1.3
1

Notes

Can be fitted to the right side of: motor-protective
circuit-breakers, transformer protective circuit
breakers and motor-protective circuit-breakers
for starter combinations

Notes

Information relevant for export to North America

Product Standards

1
5

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

Can be combined with:
Trip-indicating auxiliary contact AGM, NHI-E-…

1

Can be fitted to motor-protective circuit-breakers,
transformer-protective circuit-breakers and
motor-protective circuit-breakers for starter
combinations from serial number 01.
45 mm (PKZM0 and PKZM01) or 55 mm (PKZM4)
widths of the motor-protective circuit-breakers
remain unchanged.
NHI-E...-PKZ0-C not for use with MSC...-type motor
starter combinations.

Accessories
1 Motor-protective circuit-breakers
5 Trip-indicating auxiliary contact
Additional accessories

UL 508; CSA-C22.2No.14;
IEC 60947-4-1; CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA certified

5

4
12
20

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

11

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Auxiliary contacts, undervoltage releases

AGM2...., VHI...

1

Contact configuration
N/O = normally
open contact

Contact sequence

Circuit diagrams

For use with

NC = normally
closed contact

Part no.
Article no.

Price

Std. pack

See price
list

Trip indicators
For motor-protective circuit-breakers
2 x 1 N/O

Einschalten/Ausschalten

"+"
4.43

" I >"
4.13

4.44

4.14

"+"
4.31

" I >"
4.21

4.32

4.22

L1L2L3
"+"
"I >"
Auslösen "+"
I>
L1L2L3

PKZM0
PKZM4
PKZM0-T
PKM0
PKZM01
PKE 1)

AGM2-10-PKZ0
072898

2 off

PKZM0
PKZM4
PKZM0-T
PKM0
PKZM01
PKE 1)

AGM2-01-PKZ0
072899

2 off

PKZM0
PKZM0-T
PKM0
PKZM4

VHI20-PKZ0
203595

2 off

PKZM01

VHI20-PKZ01
278495

5 off

PKZM0
PKZM4
PKZM0-T
PKM0
PKZM01
PKE 2)

A-PKZ0(230V50Hz)
073187

2 off

PKZM0
PKZM4
PKZM0-T
PKM0
PKZM01
PKE 2)

A-PKZ0(24VDC)
073200

2 off

PKZM0
PKZM4
PKZM0-T
PKM0
PKZM01
PKE 2)

U-PKZ0(230V50Hz)
073135

2 off

CL-PKZ0
082881

1 off

"+"
"I >"

–

2 x 1 NC

Einschalten/Ausschalten

L1L2L3
"+"
"I >"
Auslösen "+"
I>
L1L2L3
"+"
"I >"

Early-make auxiliary contacts
For motor-protective circuit-breakers
2 N/O

–

–

2 N/O

–

–

3.13

3.23

I >
3.14
3.24

Shunt release (for power circuit-breakers)
–

–

–

–

–

–

C1

C2

Undervoltage release
–
–

–

D1

U<

D2

–

Current limiters
For increasing switching capacity of motor-protective circuit-breakers without auto-protection
–
–
–
PKZM0
L
PKZM4
PKE
I >>
T

Notes

12

1)

Only AGM2-...-PKZ0 manufactured on or after 06/2009 can be fitted.

2)

Only A(U)-PKZ0... with serial number 02 or higher can be fitted.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Auxiliary contacts, undervoltage releases

1.3
1

Notes

Notes

Information relevant for export to North America

Can be fitted to the right side of motor-protective
circuit-breakers

1

Product Standards
3

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

Can be combined with:
Standard auxiliary contacts
NHI11-PKZ0
NHI12-PKZ0
NHI21-PKZ0
NHI-E-…

UL 508; CSA-C22.2No.14;
IEC60947-4-1; CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA certified

Separate indication of:
a) General trip indication (overload)
b) Short-circuit trip
Local short-circuit indication by red indicator,
manually resettable.

Can be fitted to front of motor-protective circuitbreaker, 45 mm width of the motor-protective
circuit-breaker remains unchanged.
For early energization of undervoltage release,
e.g. in emergency switching off circuits to
EN 60204.
VHI20-PKZ0 cannot be used in combination with
PKZ0-X(R).

1
3

Accessories
1 Motor-protective circuit-breakers
3 Standard auxiliary contacts

Page
4
10

Can be fitted to the left side of motor-protective
circuit-breakers.
Cannot be combined with:
undervoltage release U-PKZ0
DC: Intermittent operation 5 s

1

1

Can be fitted to the left side of motor-protective
circuit-breakers.
Cannot be combined with:
A-PKZ0 shunt release
When combined with circuit-breaker, can be
used as emergency switching off device to
IEC/EN 60204.

Accessories
1 Motor-protective circuit-breakers
Further actuating voltages

Page
4
29

Max. rated operating voltage U e = 690 V, rated
uninterrupted current Iu = 63 A
Can be used for individual and group protection.
For group protection and in combination with
PKZM4, order additional BK25/3 incoming terminal
if required.
Mounting next to or behind the motor-protective
circuit-breaker.
PKZM4: 16 - 63 A: 100 kA/400 V
PKZM4: 16 - 63 A: 10 kA/690 V

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

13

1.3
1

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Accessories for motor-protective circuit-breakers in enclosures

Engineering
PKZM01, PKZM
Enclosure

Part no.

Part no.

Surface mounting enclosure
Motor-protective circuit-breaker PKZM01
CI-PKZ01

CI-PKZ01-G

Accessories

Degree of Handle
protection color

NHI..PKZ0

AGM2-..PKZ0

IP40

–
–

VHI..PKZ01

–

–

–
–
–
–
–
–
–
–
–
–

–
–

–

–

–

–
–

–
–

–

–
–

–
–
–
–
–
–

–
–
–
–
–
–

–
–
–
–

–
–
–
–

–
–
–
–

Redyellow

–
–

IP65
IP65

–
–

–
–

–
–

IP41

–

CI-PKZ01-PVT
CI-PKZ01-PVS

IP65

CI-PKZ01-SVB
CI-PKZ01-SVB-V

Motor-protective circuit-breaker PKZM0
CI-K2-PKZ0

VHI..-PKZ0

–
–
–
–
–
–
–
–
–
–

IP65

–

–

–
–

NHI-E..PKZ0

–
–
–
–

–

CI-K2-PKZ0-G

IP65

Black
–

CI-K2-PKZ0-GR
CI-PKZ0-M

IP65
IP40

Redyellow

–
–

–
–

CI-PKZ0-GM

IP55

Black
–

CI-PKZ0-GRM
Motor-protective circuit-breaker PKZM0 +
early-make auxiliary contact VHI-PKZ0
CI-K2-PKZ0-GV

IP55

IP65

Redyellow

–

Black

–
–

CI-K2-PKZ0-GRV
CI-K2-PKZ0-GVM

IP65
IP55

Redyellow

–
–

Black
–

CI-K2-PKZ0-GRVM IP55

Notes

14

Redyellow

–

–
–
–
–

–
–
–
–
–
–
–
–

–

–
–

–
–

–
–

–

1)

–
–
–
–
–
–
–
–

The combination possibilities of circuit-breakers in an enclosure with accessory modules are identified by a
1) Always required
AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

U-PKZ0
or
A-PKZ0

–

–
–

–
–

L-PKZ0

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE

1.3

PKZM4, PKZM01, PKZM0

1

Enclosure

Part no.

Part no.

Accessories

Degree of Handle
protection color

NHI..PKZ0

AGM2-..PKZ0

NHI-E..PKZ0

VHI..-PKZ0

VHI..PKZ01

–

–
–
–
–

U-PKZ0
or
A-PKZ0

L-PKZ0

Surface mounting enclosure
Motor-protective circuit-breaker PKZM4
CI-K4-PKZ4-G

IP65

Black
–

CI-K4-PKZ4-GR

Installation enclosure
Motor-protective circuit-breaker PKZM01
E-PKZ01

E-PKZ01-G

E-PKZ01-PVT
E-PKZ01-PVS

IP65

IP40

IP65

IP65

E-PKZ01-SVB
IP65
E-PKZ01-SVB-V IP65

Motor-protective circuit-breaker PKZM0
E-PKZ0

E-PKZ0-G

IP40

IP55

Redyellow

–

–
–

–

–

–
–
–
–
–
–
–
–
–
–

Redyellow

–
–

–
–
–
–
–
–
–
–
–
–

–
–

–
–

–
–

–
–

–

–

–

–
–

–
–

–
–

–
–

–

–
–

–
–

–

Black

–
–
–
–

–

–
–

–
–

–
–

–

1)

–
–
–
–
–
–
E-PKZ1-GR
IP55
Red–
–
–
yellow
–
–
–
–
The combination possibilities of circuit-breakers in an enclosure with accessory modules are identified by a
1) Always required

–

–

–

Notes

–

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

15

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Insulated enclosure

PKZM01, PKZM0, PKZM4
Degree of
protection

1

For use with

Part no.
Article no.

Price
See price
list

Std. pack

Notes

CI-PKZ01
281403

1 off

Integrated terminal for PE(N)
connection, two M25 cable entry
knockouts at top and at bottom.

CI-PKZ01-G
281404

1 off

CI-PKZ01-SVB
281405
CI-PKZ01-SVB-V
281944

1 off

IP65

CI-PKZ01-PVT
281406

1 off

IP65

CI-PKZ01-PVS
281407

1 off

PKZM01

CI-PKZ01-X
289934

1 off

PKZM0-…
+NHI or AGM
+U or A
+NHI-E
+L-PKZ0 (2 off)

CI-K2-PKZ0
219653

1 off

CI-K2-PKZ0-G
219654
CI-K2-PKZ0-GR
219655

1 off

Insulated enclosures for surface mounting
For Motor-protective circuit-breaker PKZM01
–
IP40
PKZM01
+NHI-E or
VHI-PKZ01
+U or A or NHI
+L (2 off)
With operating membrane

IP65

Lockable in Off position

IP65

Lockable in Off position in
combination with
VHI-PKZ01
With emergency switching
off mushroom button,
maintained
With emergency switching
off mushroom button, with
key-release

IP65

For extension with inserts
CI/E-PKZ01-X... unit

As insert

PKZM01
+NHI-E or
+U or A
+L (2 off)

1 off

For Motor-protective circuit-breakers PKZM0
Cover with aperture
dimensioned to accommodate
front of breaker. IP40, when
mounted turned through 90° to
left/right
With black-grey
rotary knob
With red-yellow rotary knob, for
use as emergency switching off
device to EN 60204
Cover with aperture
dimensioned to accommodate
front of breaker

IP41
with vertical mounting

IP40

PKZM0-…
+NHI or U or A
+L-PKZ0 (2 off)

CI-PKZ0-M
267083

1 off

With black-grey
rotary knob
With red-yellow rotary knob, for
use as emergency switching off
device to EN 60204

IP55

PKZM0-…
+NHI-E
+NHI or U or A
+L-PKZ0 (2 off)

CI-PKZ0-GM
260089
CI-PKZ0-GRM
260104

1 off

IP65
IP65

IP55

M25 metric cable entry knockout,
top and bottom
Cable push-through membrane top,
bottom, in the back plate and as a
control line entry.
Insulated enclosure CI-K2 incl.
N and PE terminal.

1 off

Integrated terminal for PE(N)
connection, two M25 cable entry
knockouts at top and at bottom.

1 off

For Motor-protective circuit-breakers PKZM0 with early-make VHI auxiliary contacts
With black-grey
rotary knob
With red-yellow rotary knob, for
use as emergency switching off
device to EN 60204
With black-grey
rotary knob
With red-yellow rotary knob, for
use as emergency switching off
device to EN 60204

IP65
IP65

IP55
IP55

PKZM0-... and VHI
+NHI or AGM
+U or A
+L (2 off)

CI-K2-PKZ0-GV
219657
CI-K2-PKZ0-GRV
219656

1 off

PKZM0-... and VHI
+U or A (undervoltage or shunt release)
+L-PKZ0 (2 off)

CI-PKZ0-GVM
263526
CI-PKZ0-GRVM
263525

1 off

PKZM4-…
+VHI or NHI-E
+NHI and AGM
+U or A
+L-PKZ0 (2 off)

CI-K4-PKZ4-G
225524
CI-K4-PKZ4-GR
225525

1 off

1 off

1 off

M25 metric cable entry knockout,
top and bottom
Cable push-through membrane top,
bottom, in the back plate and as a
control line entry.
Insulated enclosure CI-K2 incl.
N and PE terminal.
Integrated terminal for PE(N) connection, two M25 cable entry
knockouts at top and at bottom.

For Motor-protective circuit-breakers PKZM4

16

With black-grey rotary knob

IP65

With red-yellow rotary knob, for
use as emergency switching off
device to EN 60204

IP65

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1 off

Metric knockout:
Top and bottom: M25/M32
In the back plate: M25/M32
Control cable entry: M20
CI-K4 insulated enclosure including
insulated PE terminal

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Insulated enclosure

1.3

E-PKZ
Degree of
protection

For use with

Part no.
Article no.

Price
See price
list

Std. pack

Information relevant for export to
North America

1 off

Product Standards

E-PKZ01-G
281634

1 off

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

1

Insulated enclosures for flush mounting
For Motor-protective circuit-breaker PKZM01
Integrated terminal for PE(N) connection.
Front IP40
PKZM01
+NHI or U or
A
+NHI-E or
VHI
+L (2 off)
With operating
Front IP65
membrane

E-PKZ01
281633

Lockable in Off
position

Front IP65

PKZM01
+U or A
+NHI-E

E-PKZ01-SVB
281635

1 off

Lockable in Off
position, in combination with VHI-PKZ01

Front IP65

PKZM01
+U or A
+NHI-E or
VHI

E-PKZ01-SVB-V
281943

1 off

With emergency
switching off
mushroom button,
maintained

Front IP65

E-PKZ01-PVT
281636

1 off

With emergency
switching off
mushroom button,
with key-release

Front IP65

E-PKZ01-PVS
281637

1 off

For extension with
inserts CI/E-PKZ01X... unit

As insert

E-PKZ01-X
289935

1 off

For Motor-protective circuit-breakers PKZM0
Integrated terminal for PE(N) connection.
Cover with aperture
Front IP40
PKZM0-…
dimensioned to
+NHI or U or
accommodate front
A +L-PKZ0
of breaker
(2 parts)

E-PKZ0
072906

1 off

With black-grey
rotary knob

E-PKZ0-G
072907

With red-yellow
rotary knob, for use
as emergency
switching off device
to EN 60204

Front IP55

Front IP55

PKZM01

PKZM0-…
+NHI or U or
A
+NHI-E
+L-PKZ0
(2 parts)

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

E-PKZ0-GR
072908

1 off

Product Standards

1 off

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Degree of Protection

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

UL 508; CSA-C22.2
No.14; IEC609474-1; CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA
certified

UL 508; CSA-C22.2
No.14; IEC609474-1; CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA
certified
UL 508; CSA-C22.2
No.14; IEC609474-1; CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA
certified
IEC: Front IP55,
UL/CSA Type:
1,12, 3R

17

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Insulated enclosure

CI-PKZ

1

Degree of
protection

For use with

Part no.
Article no.

Price

Std. pack

Information relevant for export to
North America

Product Standards

See price
list
Insulated enclosures for surface mounting
For Motor-protective circuit-breaker PKZM01s
Integrated terminal for PE(N) connection.
IP41

PKZM01
+NHI-E or
VHI-PKZ01
+U or A or
NHI
+L (2 off)

CI-PKZ01-NA
281408

1 off

With operating
membrane

IP65

PKZM01
+NHI-E or
VHI-PKZ01
+U or A or
NHI
+L (2 off)

CI-PKZ01-NA-G
281409

1 off

Lockable in Off
position

IP65

PKZM01
+NHI-E or
VHI-PKZ01
+U or A
+L (2 off)

CI-PKZ01-NA-SVB
281630

1 off

Lockable in Off
position, in
combination with
VHI-PKZ01

IP65

PKZM01
+NHI-E
+U or A
+L (2 off)

CI-PKZ01-NA-SVB-V
281945

1 off

With emergency
switching off
mushroom button,
maintained

IP65

CI-PKZ01-NA-PVT
281631

1 off

With emergency
switching off
mushroom button,
with key-release

IP65

CI-PKZ01-NA-PVS
281632

1 off

For Motor-protective circuit-breakers PKZM0
Integrated N and PE terminals; lower section without knockouts
With black-grey
IP55
PKZM0-…
CI-K2-PKZ0-NA-G
rotary knob
+NHI or U or
262680
A
+NHI-E
+L-PKZ0
(2 parts)
With red-yellow
IP55
CI-K2-PKZ0-NA-GR

1 off

1 off

rotary knob, for use
262681
as emergency
switching off device
to EN 60204
For Motor-protective circuit-breakers PKZM0 with early-make auxiliary contacts
Integrated N and PE terminals; lower section without knockouts

18

With black-grey
rotary knob

IP55

With red-yellow
rotary knob, for use
as emergency
switching off device
to EN 60204

IP55

PKZM0-…
+VHI… +
U…
+L-PKZ0
(2 parts)

CI-K2-PKZ0-NA-GV
262682

1 off

CI-K2-PKZ0-NA-GRV
262683

1 off

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

UL 508; CSA-C22.2
No.14; IEC609474-1; CE marking
UL File No.
E36332
UL CCN
NLRV
CSA File No.
12528
CSA Class No.
3211-05
NA Certification
UL Listed, CSA
certified
Specially designed for NA
Degree of Protection IEC: IP41, UL/CSA
Type: -

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Insulated enclosure

1.3

SVB-PKZ, CL/EPKZ01
Degree of
protection

1
For use with

Part no.
Article no.

Price
See price
list

Std. pack

Information relevant for export to
North America

3 off

Product Standards

Insulated enclosures, accessories
Padlocking feature
For up to 3 padlocks with 3 – 6 mm hasp thickness, for use as main switch to
IEC/EN60204
Lockable in the
–
CI-K2-PKZ0-G(R)(V)
SVB-PKZ0-CI
0-position of the PKZM0
035129
CI-PKZ0-G(R)(V)M
or Motor-protective
circuit-breaker PKZM4.
–
–
E-PKZ0-G(R)
SVB-PKZ0-E
035127

–

–

3 off

CI-K4-PKZ4-G(R)

SVB-PKZ4-CI
225526

1 off

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

UL 508; CSA-C22.2
No.14; IEC609474-1; CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA
certified

Neutral terminal
For connection of a 5th conductor
Flexible, 1 - 4 mm²

–

CI-K2-PKZ0-...

K-CI-K1/2
207451

20 off

63 A, flexible,
6 - 16 mm²

–

CI-K4-PKZ4-G(R)

K25/1
096200

10 off

–

–

E-PKZ0(-G)(-GR)
E-PKZ01(-G)

N-PKZ0
082160

20 off

CI/E-PKZ01XG
289936

1 off

PKZM01
+NHI-E
+U or A
+L (2 off)
PKZM01
+NHI-E or VHI-PKZ01
+U or A
+L (2 off)
PKZM01
+NHI-E or VHI-PKZ01
+U or A
+L (2 off)

CI/E-PKZ01XSVB
289939

1 off

CI/E-PKZ01XPVT
289937

1 off

CI/E-PKZ01XPVS
289938

1 off

PKZM01
VHI-PKZ01
+U or A
+L (2 off)

CI/E-PKZ01XSVB-V
289980

1 off

Units for insulated enclosures for PKZ01
Combinable with CI-PKZ01-X and E-PKZ01-X.
PKZM01
With operating membrane Front IP65
+NHI-E or VHI-PKZ01
+U or A or NHI
+L (2 off)
Lockable in Off position

Front IP65

With emergency
switching off mushroom
button, maintained

Front IP65

With emergency
switching off mushroom
button, with key-release

Front IP65

Lockable in Off position,
in combination with
VHI-PKZ01

Front IP65

UL/CSA certification not required

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

19

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Accessories

Accessories

1

Cable entry
Metric cable glands to EN 50262
• With lock nut and built-in strain relief
• IP68 up to 5 bar, halogen free

Metric diaphragm grommets
• IP66
• With integral push-through diaphragm

Door coupling
handles
Degree of protection IP65, UL/CS
Type 4X / Type12

Clamp cover

Pluggable
extension shaft
–

External cable diameter
mm

M20

20.5

6 - 13

V-M20
206910

20 off

M25

25.5

9 - 17

V-M25
206911

20 off

M32

32.5

13 - 21

V-M32
206912

10 off

M32

32.5

18 - 25

V-M32G
226156

10 off

M20

20.5

1 - 13

100 off

M25

25.5

1 - 18

KT-M20
207602
KT-M25
207603

M32

32.5

1 - 25

KT-M32
207604

100 off

For use
with

Part no.
Article no.

Price
See price
list

Part no.
Article no.

Price
See price list

Std. pack

100 off

Std. pack

Notes

Pluggable PKZ0-XAH extension
shaft, can be cut to any required
length for installation depths of
100…240 mm.
Follower included in delivery.
With ON/OFF switch position and
“+” (tripped), lockable
With 3 padlocks, 4 – 8 mm hasp.
Cannot be used in combination with
VHI20-PKZ0.

For use as main switch to IEC/EN 60204

Black

PKZM0
PKZM4

PKZ0-XH1)
106132

1 off

For use as a main switch with emergency
switching off function to EN 60204

Redyellow

PKZM0
PKZM4

PKZ0-XRH1)
106133

1 off

For use as a main switch to EN 60204 in MCC
power distribution systems and with PKZM0
installed rotated by 90°

Black

PKZM0
PKZM4

PKZ0-XH-MCC1)
106136

1 off

For use as a main switch with emergency
switching off function to EN 60204 in MCC
power distribution systems and with PKZM0
installed rotated by 90°
For use as main switch to IEC/EN 60204

Redyellow

PKZM0
PKZM4

PKZ0-XRH-MCC1)
106137

1 off

Black

PKE

PKE-XH1)
142416

1 off

For use as a main switch with emergency
switching off function to EN 60204

Redyellow

PKE

PKE-XRH1)
142417

1 off

For use as a main switch to EN 60204 in MCC
power distribution systems and with PKE
installed rotated by 90°

Black

PKE

PKE-XH-MCC1)
142418

1 off

For use as a main switch with emergencyswitching off function to EN 60204 in MCC
power distribution systems and with PKE
installed rotated by 90°
For increasing the degree of protection of the
PKZM4 to IP2X

Redyellow

PKE

PKE-XRH-MCC1)
142419

1 off

–

PKZM4

HB-PKZ42)
256581

1 off

Suitable for connecting cables with
a max. external diameter of 9.5 mm

–

PKZM0
PKZM4

PKZ0-XAH1)
106134

1 off

Follower not included

–

Pluggable PKZ0-XAH extension
shaft, can be cut to any required
length for installation depths of
100…240 mm.
Follower included in delivery.
With ON/OFF switch position and
“+” (tripped), lockable
With 3 padlocks, 4 – 8 mm hasp.

Information relevant for export to North America
1)

20

Drilling dimensions
mm

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Degree of Protection

UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA certified
IEC: IP65, UL/CSA Type: 4X, 12

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

2)

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

UL 508; CSA-C22.2 No.14;
IEC60947-4-1; CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA certified

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Accessories

1.3

Accessories

1
Notes

Part no.
Article no.

Stepless
adjustment via
scale from
75 – 115 mm.

M22-TA
226161

Price
See price
list

Std. pack

Information relevant for export to
North America

1 off

Product Standards

Telescopic adapters
With 45 mm top-hat
rail to IEC/EN 60715
for compensation of
the mounting depth
of rear-mounted
devices enclosures
CI-K and cabinets

Telescopic clip

Lockable rotary
handle

For locking motor-protective
circuit-breakers PKZM0, PKZM4
and PKE as a main switch in
compliance with EN 60204.
Can be padlocked in the “0”
position.
Hasp thickness: 3 – 6.35 mm

Can not be
combined with
VHI-PKZ0.

Holding facility

To prevent tampering with the
overload release and the test
function, it can be sealed using
industry standard sealing wire
For use with motor-protective
circuit-breakers PKZM0 and
PKZM4

–

PL-PKZ0
203599

5 off

Mounting angle
bracket

For screw fixing to mounting
plate

–

PKE32-XMB
134837

20 off

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

AK-PKZ0
030851

5 off

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

Product Standards
NA Certification

Documentation

Indicator lights with
glow lamp

Motor-protective circuitbreakers PKZM0, overload
monitoring of EEx e motors

German/English

AWB1210-1458D/GB
266164

1 off

Motor-protective circuitbreakers PKZM4, overload
monitoring of EEx e motors

German/English

AWB1210-1457D/GB
266165

1 off

Motor-protective circuitbreakers PKE, EEx electric
motor overload monitoring

German/English

AWB1210-1631DE/EN
134836

1 off

For use withColorVoltage

Color

Voltage
Us

Part no.
Article no.

V

Price
See price
list

IEC/EN60947-5;
UL 508; CSA-C22.2
No.14-05; CSAC22.2 No.94-91;
CE marking
E29184
NKCR
012528
3211-03
UL Listed,
CSA certified

UL 508; CSA-C22.2
No.14; IEC/EN 609474-1; CE marking
E36332
NLRV
12528
3211-05
UL Listed,
CSA certified

UL 508; CSA-C22.2
No.14; IEC/EN 609474-1; CE marking
Request filed for UL
and CSA

Std. pack

CI-K2-PKZ0-… , CI-K4-PKZ4 ,
CI-PKZ0(1) , E-PKZ0(1)

White

110 - 230

L-PKZ0(230V)
082151

10 off

CI-K2-PKZ0-… , CI-K4-PKZ4 ,
CI-PKZ0(1) , E-PKZ0(1)

White

230 - 400

L-PKZ0(400V)
082152

10 off

CI-K2-PKZ0-… , CI-K4-PKZ4 ,
CI-PKZ0(1) , E-PKZ0(1)

White

415 - 500

L-PKZ0(500V)
082153

5 off

CI-K2-PKZ0-… , CI-K4-PKZ4 ,
CI-PKZ0(1) , E-PKZ0(1)

Green

110 - 230

L-PKZ0-GN(230V)
082154

10 off

CI-K2-PKZ0-… , CI-K4-PKZ4 ,
CI-PKZ0(1) , E-PKZ0(1)

Green

230 - 400

L-PKZ0-GN(400V)
082155

10 off

CI-K2-PKZ0-… , CI-K4-PKZ4 ,
CI-PKZ0(1) , E-PKZ0(1)

Green

415 - 500

L-PKZ0-GN(500V)
082156

5 off

CI-K2-PKZ0-… , CI-K4-PKZ4 ,
CI-PKZ0(1) , E-PKZ0(1)

Red

110 - 230

L-PKZ0-RT(230V)
082157

10 off

CI-K2-PKZ0-… , CI-K4-PKZ4 ,
CI-PKZ0(1) , E-PKZ0(1)

Red

230 - 400

L-PKZ0-RT(400V)
082158

10 off

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

21

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Busbar adapters

Busbar adapters for PKZ and PKE
Approved to UL508.
For fitting to flat copper busbars with 60mm between busbar centers, suitable for 5 mm
and 10 mm busbar thickness.

1

Rated
operational
voltage
Ue

Conductor
crosssection

V

Adapter
width

Mounting
rails

mm

Number

For use with

Part no.
Article no.

Price
See
price list

Std. pack

Notes

Rated operational
current 16 A
For starters with springloaded terminals

690

AWG 14
(2.5 mm²)

45

2

PKZM0-C + DILMC7
PKZM0-C + DILMC9
PKZM0-C + DILMC12

BBA0C-16
101455

4 off

According to UL 508: Ie = 12 A

Rated operational
current 25 A
For reversing starters

690

AWG 12
(4 mm²)

90

1

PKZM0, PKE + 2 x
DILM7-01
PKZM0, PKE + 2 x
DILM9-01
PKZM0, PKE + 2 x
DILM12-01
MSC-R-0,25-M7… MSC-R-12-M12…

BBA0R-25
101453

2 off

In combination with individual
components PKZM0 and DILM, use
reversing starter kit PKZM0-XRM12.
Fully assembled and tested
combination with MSC-R
Chapter 1.4 (Page 18)
Only busbar adapters/wiring sets
manufactured on or after CW35/
2009 can be used for PKE.

Can be used universally

690

AWG 12
(4 mm²)

45

2

–

BBA0-25/2TS
101481

4 off

Mounting rails can be moved within
1.25 mm grid.

For DOL starters

690

AWG 12
(4 mm²)

45

1

PKZM0, PKE +
2 x DILM17-01
PKZM0, PKE +
2 x DILM2501PKZM0, PKE +
2 x DILM25-01
PKZM0, PKE +
2 x DILM32-01
MSC-R-16-M17…
MSC-R-32-M32…

BBA0-25
101451

4 off

In combination with individual
components PKZM0 and DILM, use
DOL starter kit PKZM0-XRM12.
Fully assembled and tested
combination with MSC-D
Chapter 1.4 (Page 2)
Only busbar adapters/wiring sets
manufactured on or after CW35/
2009 can be used for PKE.

For soft starters

690

AWG 12
(4 mm²)

45

1

PKZM0, PKE +
DS7...004N...
PKZM0, PKE +
DS7...007N...
PKZM0, PKE +
DS7...009N...
PKZM0, PKE +
DS7...012N...

BBA0L-25
142526

1 off

–

Rated operational
current 32 A
For reversing starters

690

AWG 10
(6 mm²)

90

3

PKZM0, PKE + 2 x
DILM17-01
PKZM0, PKE + 2 x
DILM25-01
PKZM0, PKE + 2 x
DILM32-01
MSC-R-16-M17… MSC-R-32-M32…

BBA0R-32
101454

2 off

In combination with single
components PKZM0 and DILM,
wiring kit PKZM0-XM32DE and
reversing starter wiring kit
DILM32-XRL can be used.
Fully assembled and tested
combination with MSC-R
Chapter 1.4 (Page 18)
Only busbaradapters/wiring sets
manufactured on or after CW 35/
2009 can be used for PKE.

UL 508A; CSA-C22.2 No. 14;
IEC60439-1; CE marking
UL File No.E300273
NMTR, NMTRZ

CSA File No.
CSA Class No.
NA Certification
Max. Voltage Rating

Information relevant for export to North America

Product Standards
UL File No.
UL CCN

22

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

232140
3211-37
UL Listed, CSA certified
600 V AC

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Busbar adapters

1.3
1

Rated
operational
voltage
Ue

Conductor
crosssection

V

Adapter
width

Mounting
rails

mm

Number

For use with

Part no.
Article no.

Price
See
price list

Std. pack

Notes

Rated operational
current 32 A
Can be used universally.

690

–

45

2

PKZM0…, PKE +
DILM…

BBA0-32/2TS-C 2)
116708

4 off

Universal adapter 1-, 2- and 3phase applications.
Mounting rail can be moved within
1.25 mm grid.
For conductor cross-sections,
round conductors of up to 6 mm 2.
Only busbaradapters/wiring sets
manufactured on or after CW 35/
2009 can be used for PKE.

For DOL starters.

690

AWG 10
(6 mm²)

45

2

PKZM0, PKE +
DILM17
PKZM0, PKE +
DILM25
PKZM0, PKE +
DILM32
MSC-D-16-M17… MSC-D-32-M32…

BBA0-32 1)
101452

4 off

In combination with individual
components PKZM0 and DILM
wiring kit PKZM0-XM32DE can be
used.
Fully assembled and tested
combination with MSC-D
Chapter 1.4 (Page 2)
Only busbar adapters/wiring sets
manufactured on or after CW35/
2009 can be used for PKE.

For soft starters

690

AWG 10
(6 mm²)

45

2

PKZM0, PKE +
DS7...016N...
PKZM0, PKE +
DS7...024N...
PKZM0, PKE +
DS7...032N...

BBA0L-32
142527

1 off

–

For 160 mm adapter
system with motorprotective circuitbreakers
–

690

AWG 10
(6 mm²)

45

1

PKZM0, PKE

BBA0K-32
142528

1 off

–

Rated operational
current 63 A
For DOL starters.

690

AWG 8
(10 mm²)

55

2

PKZM4 + DILM17
PKZM4 + DILM25
PKZM4 + DILM32
PKZM4 + DILM40
PKZM4 + DILM50
PKZM4 + DILM65

BBA4L-63 1)
101459

4 off

The following can be used to
establish an electrical connection:
For PKZM4 + DILM17 to DILM32:
MVS-LB0-0M-G
For PKZM4 + DILM40 to DILM65:
PKZM4-XM65DE.

For motor-protective
circuit-breakers

690

AWG 8
(10 mm²)

54

1

PKZM4

BBA4-63 1)
101457

4 off

–

Information relevant for export to North America
1)
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Max. Voltage Rating

2)
UL 508; CSA-C22.2 No.14; IEC60439-1; CE marking
E300273
NMTR, NMTR7
232140
3211-37
UL Listed, CSA certified
600 V AC

Product Standards
UL File No.
UL CCN
NA Certification
Max. Voltage Rating

UL 508; CSA-C22.2 No.14;
IEC60439-1; CE marking
E300273
NMTR, NMTR7
UL Listed, CSA certified
600 V AC

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

23

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Busbar adapters

BBA, PKZM0-XM
Rated
operational
voltage
Ue

1

Conductor
crosssection

V

Adapter
width

Mounting
rails

For use with

Part no.
Article no.

Price
See
price list

Std. pack

Notes

mm

Number

–

–

45

2

–

BBA0/2TS-L1)
101482

4 off

Mounting rails can be moved within
a 1.25 mm grid.
Can be used to mount reversing and
star-delta starters.

–

–

54

2

–

BBA4/2TS-L1)
101483

4 off

Mounting rails can be moved within
a 1.25 mm grid.
Can be used to mount reversing and
star-delta starters.

Side-mounted module,
can be attached on
both sides.

–

–

9

–

–

BBA-XSM 1)
101484

10 off

Can be grouped with busbar adapters in order to extend the mounting
width.

Busbar adapters
accessories
Mounting rails

–

–

45

–

BBA…

PKZM0-XMR 2)
239364

10 off

–

Busbar adapters
accessories
Mounting rails

–

–

54

–

BBA…

PKZM0-XMR54 2)
113911

10 off

–

Busbar adapters
accessories
Mounting rails

–

–

72

–

BBA…

PKZM0-XMR72 2)
113912

10 off

–

Connecting cable
–

–

–

–

–

BBA…

BBA-XLT-6-130 3)
116902

30 off

–

–

–

–

–

BBA…

BBA-XLT-16-142 3)
116903

30 off

–

Without electrical
contacts
Empty module.

Information relevant for export to North America
1)
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Max. Voltage Rating

2)
UL 508A; CSA-C22.2 No.14; IEC60439-1; CE marking
E300273
NMTR, NMTR7
232140
3211-37
UL Listed, CSA certified
600 V AC

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

3)
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

24

UL 508A; CSA-C22.2 No.14; IEC60439-1; CE marking
On request
On request
On request
On request
UL Recognized, CSA certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

UL 508A; CSA-C22.2 No.14; IEC60947-4-1; CE marking
E300273
NMTR, NMTR7
232140
3211-37
UL Listed, CSA certified

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Wiring sets

1.3

Wiring set
For use with

Part no.
Article no.

DOL starter

PKZM0, PKE + DILM7
PKZM0, PKE + DILM9
PKZM0, PKE + DILM12
PKZM0, PKE + DILM15
DS7-34…SX004…
DS7-34…SX007…
DS7-34…SX009…
DS7-34…SX012…

DOL starter

Std. pack

Notes

PKZM0-XDM12
283149

1 off

Consists of:
• Mechanical connection element for PKZM0 and contactor
• Main supply wiring between PKZM0 and contactor
with tool-less plug connection
• Cable routing
As auxiliary contact, use DILA-XHIT...
Chapter 1.1 (Page 38)
Cannot be combined with NHI-E…PKZ0-C.
U e ̰ 415 V 1)

PKZM0, PKE + DILM17
PKZM0, PKE + DILM25
PKZM0, PKE + DILM32

PKZM0-XDM32
283153

1 off

Consists of:
• Top-hat rail adapter plates
• Power supply wiring between PKZ and contactor 1)

PKZM4 + DILM40
PKZM4 + DILM50
PKZM4 + DILM65

PKZM4-XDM65
101053

1 off

Reversing starters

PKZM0, PKE + DILM7-01
PKZM0, PKE + DILM9-01
PKZM0, PKE + DILM12-01

PKZM0-XRM12
283185

1 off

Consists of:
• Mechanical connection element for PKZM0 and contactor
• Reversing starters main supply wiring with tool-less plug connection
• Control cables for electrical interlocking in tool-less plug connection:
– K1M: A1 -K2M: 21
– K1M: 21 -K2M: A1
– K1M: A2 -K2M: A2
• Cable routing
As auxiliary contact DILA-XHIT...use
Chapter 1.1 (Page 38)
Can not be combined with AGM ϋ
PKZ0.
U e ̰ 415 V 1)

Reversing starters

PKZM0, PKE + DILM17
PKZM0, PKE + DILM25
PKZM0, PKE + DILM32

PKZM0-XRM32
283189

1 off

Consists of:
• Top-hat rail adapter plates
• Reversing starters supply wiring1)

Wiring kit

PKZM0, PKE + DILM17
PKZM0, PKE + DILM25
PKZM0, PKE + DILM32
DS7-34…SX016…
DS7-34…SX024…
DS7-34…SX032…
PKZM4 + DILM40
PKZM4 + DILM50
PKZM4 + DILM65

PKZM0-XM32DE
239349

5 off

• Main supply wiring between PKZM0 and contactor
• Use only in combination with busbar adapter or mounting rail adapter
plate

PKZM4-XM65DE
101056

5 off

• Main current supply between PKZM4 and contactor

Top-hat rail adapter plates

PKZM0-XDM12
PKZM0-XRM12

PKZM0-XC45
283132

4 off

Consists of:
• 45 mm wide adapter plate
• Connection element for side-by-side positioning of further plates 1)

Top-hat rail adapter plates

PKZM4 + DILM40
PKZM4 + DILM50
PKZM4 + DILM65

PKZM4-XC55/2
101054

4 off

Consists of:
• 55 mm wide adapter plate
• Connection cam for additional plates 1)
• For use with reversing and start-delta starters

Soft starters

PKZM0, PKE + DS7...004N...
PKZM0, PKE + DS7...007N...
PKZM0, PKE + DS7...009N...
PKZM0, PKE + DS7...012N...

PKZM0-XC45L
142529

1 off

Consists of:
• 45 mm wide adapter plate

Soft starters

PKZM0, PKE + DS7...016N...
PKZM0, PKE + DS7...024N...
PKZM0, PKE + DS7...032N...

PKZM0-XC45L/2
142570

1 off

Consists of:
• 45 mm wide adapter plate

Notes

Price
See price
list

1)

1

Use only busbar adapters/wiring sets manufactured on or after CW35/2009 for PKE.

Information relevant for export to North America
2)

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

3)

UL 508; CSA-C22.2 No.14; IEC60947-4-1;
CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA certified

UL/CSA certification not
required

4)

Product Standards
UL File No.
UL CCN
NA Certification
Max. Voltage Rating

UL 508; CSA-C22.2 No.14;
IEC60947-4-1; CE marking
E300273
NMTR, NMTR7
UL Listed, CSA certified
600 V AC

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

25

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Motor feeder plugs, three-phase commoning links

Motor feeder plug

1
Description

For use with

Part no.
Article no.

Price
See price
list

PE module with contact plate
DILM(C)7
DILM12-XMCE
DILM(C)9
121764
DILM(C)12
DILM(C)15

Std. pack

Notes

Information relevant for export to
North America

5 off

35 x 7.5 (15) mm mounting
rail (as per DIN EN 60715)
with PE function required.
For connection of:
PE 0.75 – 4 mm2

Product Standards UL 508; CSA-C22.2
No. 14; IEC60947-4-1;
CE marking
NA Certification
Request filed for UL
and CSA

1 off

35 x 7.5 (15) mm mounting
rail (as per DIN EN 60715)
with PE function required.
For connection of:
L1, L2, L3, PE 0.75 – 2.5 mm 2

Product Standards IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No. 14-05; CE marking
NA Certification
Request filed for UL
and CSA

1 off

For connection of:
L1, L2, L3, PE 0.75 – 2.5 mm 2

Product Standards IEC/EN 60947-4-1;
UL 508; CSA-C22.2
No. 14-05; CE marking
NA Certification
Request filed for UL
and CSA

Motor feeder plug with PE module andcontact plate
DILM(C)7
DILM(C)9
DILM(C)12
DILM(C)15

DILM12-XMCP/E
121769

Motor feeder plug with PE module without
contact plate
PKZM0/PKE + DILM(C)7
PKZM0/PKE + DILM(C)9
PKZM0/PKE + DILM(C)12
PKZM0/PKE + DILM(C)15
MSC-D(E)-…-M7…
MSC-D(E)-…-M9…
MSC-D(E)-…-M15…

DILM12-XMCP/T
121770

Three-phase commoning links, incoming unit via terminals 1, 3, and 5
Finger- and back-of-hand-proof, short-circuit proof, U e=690 V, Iu=63 A
Can be extended through rotated installation
Circuit-breakers
Length
Unit width
Part no.
Article no.
Number
mm
mm

Price
See price
list

For PKZM0-... or PKE without side-mounted auxiliary contacts or voltage
releases
2
90
45
B3.0/2-PKZ01)
063961

Std. pack

Notes

10 off

For parallel feeding of multiple
motor-protective circuit-breakers on
terminals 1, 3, and 5

B3.0/3-PKZ01)
232289
4
180
45
B3.0/4-PKZ01)
063960
5
225
45
B3.0/5-PKZ01)
232290
For motor-protective circuit-breakers with one auxiliary contact or tripindicating auxiliary contact each fitted to right side
2
99
45 + 9
B3.1/2-PKZ01)
044945

10 off

B3.1/3-PKZ01)
044946
4
207
45 + 9
B3.1/4-PKZ01)
044947
5
261
45 + 9
B3.1/5-PKZ01)
044948
For PKZM0-... or PKE with one auxiliary contact or trip-indicating auxiliary
contact each fitted to right side, or one voltage release fitted on left side

10 off

3

3

135

153

45

45 + 9

2

108

45 + 18

4

234

45 + 18

B3.2/2-PKZ01)
063963
B3.2/4-PKZ01)
063959

10 off
10 off

10 off

For parallel feeding of multiple
motor-protective circuit-breakers on
terminals 1, 3, and 5

10 off
10 off

10 off
10 off

For parallel feeding of multiple
motor-protective circuit-breakers on
terminals 1, 3, and 5

Information relevant for export to North America
1)
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
26

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

UL 508A; CSA-C22.2 No.14; IEC60947-4-1; CE marking
E36332
NLRV
98494
3211-06
UL Listed, CSA certified

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Incoming terminals

1.3

HB3...PKZO, BK...I3-PKZ
Circuitbreakers

For use
with

1

Unit width

Number

Part no.
Article no.

Price
See price
list

Std. pack

Notes

20 off

–

mm

Shroud for unused terminals
Protection against direct contact.
For covering unused terminals on three-phase commoning link B3...-PKZ0
–
–
–
H-B3-PKZ01)
032721
Incoming terminals
–
PKZM0
PKE

–

BK25/3-PKZ02)
032720

5 off

For three-phase commoning link,
protected against accidental contact,
U e = 690 V, Iu = 63 A
For conductor cross-sections:
2.5 - 25 mm 2 stranded
2.5 - 16 mm 2 flexible with ferrule
AWG 14 - 6, usable on terminals 1, 3,
and 5

–

PKZM0

–

BK25/3-PKZ0-E3)
262518

5 off

–

PKZM4

–

BK50/3-PKZ4-E4)
272165

1 off

For three-phase commoning link,
protected against accidental contact,
U e = 690 V, Iu = 60 A
For conductor cross-sections:
2.5 - 25 mm 2 stranded
2.5 - 16 mm 2 flexible with ferrule
AWG 14 - 6
For assembly of Type E starters.
Can be combined with three-phase
commoning link B3…PKZ4.
I u = 120 A.
For assembly of Type E starters.

Information relevant for export to North America

1)
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

2)
UL 508; CSA-C22.2 No.14; IEC60947-4-1;
CE marking
E36332
NLRV
98494
3211-06
UL Listed, CSA certified

Product Standards

UL 508; CSA-C22.2 No.14; IEC60947-4-1;
CE marking
E36332
NLRV
98494
3211-06
UL Listed, CSA certified

Product Standards

3)
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

UL 508; CSA-C22.2 No.14; IEC60947-4-1;
CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA certified

4)

PKZM0/PKE, line terminal required for
Type E/F applications

UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for

UL 508; CSA-C22.2 No.14; IEC60947-4-1;
CE marking
E36332
NLRV
12528
3211-06
UL Listed, CSA certified
PKZM4/PKE, line terminal required for
Type E/F applications

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

27

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Three-phase commoning links

Three-phase commoning links

1

Finger- and back-of-hand-proof, short-circuit proof Ue= 690 V, Iu= 128 A
Circuit-breakers

Length

Unit width

Number

mm

mm

Part no.
Article no.

Price
See price
list

Std. pack

Information relevant for export to
North America

Product Standards UL 508; CSA-C22.2 No.14;
IEC60947-4-1; CE marking
E36332
UL File No.
NLRV
UL CCN
12528
CSA File No.
3211-06
CSA Class No.
UL Listed, CSA certified
NA Certification

For PKZM4 without side-mounted auxiliary contacts or voltage releases
2

110

55

B3.0/2-PKZ4
220220

1 off

3

165

55

B3.0/3-PKZ4
220221

1 off

4

220

55

B3.0/4-PKZ4
220222

1 off

For PKZM4 with one auxiliary contact or trip-indicating auxiliary contact each
fitted on the right side
B3.1/2-PKZ4
1 off
2
119
55 + 9
220223
3

183

55 + 9

B3.1/3-PKZ4
220224

1 off

4

247

55 + 9

B3.1/4-PKZ4
220225

1 off

For PKZM4 with one auxiliary contact or trip-indicating auxiliary contact each
fitted to right side, or one voltage release fitted to left side
2

128

55 + 18

B3.2/2-PKZ4
220226

1 off

4

274

55 + 18

B3.2/4-PKZ4
220227

1 off

Shroud for unused terminals
Protection against direct contact.
To cover unused terminals on three-phase commoning link

28

Circuit-breakers

Length

Unit width

Number

mm

mm

–

–

–

Part no.
Article no.

H-B3-PKZ4
220228

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Price
See price
list

Std. pack

Information relevant for export to
North America

10 off

Product Standards UL 508; CSA-C22.2 No.14;
IEC60947-4-1; CE marking
E36332
UL File No.
NLRV
UL CCN
12528
CSA File No.
3211-06
CSA Class No.
UL Listed, CSA certified
NA Certification

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Actuating voltages

1.3

A-PKZO, U-PKZO
Actuating voltage

1
Part no.
Article no.

Price
See price
list

Std. pack

Part no.
Article no.

Price
See price
list

Std. pack

Notes

Shunt release, undervoltage
release
AC
Standard voltage
24 V 50 Hz

A-PKZ0(24V50Hz) 1)
073181

2 off

U-PKZ0(24V50Hz) 1)
073129

2 off

110 V 50 Hz

A-PKZ0(110V50Hz) 1)
073184

2 off

U-PKZ0(110V50Hz) 1)
073132

2 off

220 V 50 Hz

A-PKZ0(220V50Hz) 1)
073186

2 off

U-PKZ0(220V50Hz) 1)
073134

2 off

230 V 50 Hz

A-PKZ0(230V50Hz) 1)
073187

2 off

U-PKZ0(230V50Hz) 1)
073135

2 off

240 V 50 Hz

A-PKZ0(240V50Hz) 1)
073188

2 off

U-PKZ0(240V50Hz) 1)
073136

2 off

380 V 50 Hz

A-PKZ0(380V50Hz) 1)
073189

2 off

U-PKZ0(380V50Hz) 1)
073137

2 off

400 V 50 Hz

A-PKZ0(400V50Hz) 1)
073190

2 off

U-PKZ0(400V50Hz) 1)
073138

2 off

415 V 50 Hz

A-PKZ0(415V50Hz) 1)
073191

2 off

U-PKZ0(415V50Hz) 1)
073139

2 off

120 V 60 Hz

A-PKZ0(120V60Hz) 1)
073195

2 off

U-PKZ0(120V60Hz) 1)
073143

2 off

240 V 60 Hz

A-PKZ0(240V60Hz) 1)
073198
A-PKZ0(440V60Hz) 1)
082164

2 off

U-PKZ0(240V60Hz) 1)
073146
U-PKZ0(440V60Hz) 1)
082161

2 off

A-PKZ0(480V60Hz) 1)
073199

2 off

U-PKZ0(480V60Hz) 1)
073147

2 off

…V 50 Hz (24 - 500 V)

A-PKZ0(*V50Hz) 1)
982165

2 off

U-PKZ0(*V50Hz)
982162

…V 60 Hz (24 – 600 V)

A-PKZ0(*V60Hz) 1)
982166

2 off

U-PKZ0(*V60Hz)
982163

A-PKZ0(24VDC)1)
073200

2 off

A-PKZ0(110VDC)1)
073203

2 off

440 V 60 Hz
480 V 60 Hz

2 off

Only A(U)-PKZ0... with
serial number 02 or higher
can be fitted

2 off

Non-standard voltages not covered
by above standard voltages
The part number for
ordering consists of the
basic part number and the
actuating voltage.
For non-standard voltages,
specify the required
actuating voltage within
the indicated range
(... - ... V).
Minimum order quantity is
10 units

DC
Standard voltage
24 V DC

110 V DC

PKE can be fitted only with
A(U)-PKZ0... with serial
number 02 or higher.

Information relevant for export to North America

1)
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking
E36332
NLRV
12528
3211-05
UL Listed, CSA certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

29

1.3
Engineering

1- and 2-pole-connected PKZM0, PKZM4
with AC and DC

2-pole-connected PKZM0(1) and PKZM4 with CL-PKZ0
L1

1

3

I>

I>

2

4

5

1

3

I>

I>

I>

2

4

6

N

5

CL-PKZ0
4

2

I>
6

6

I >> I >> I >>
1
3
5

PKZ0Z
1

3

5

I>

I>

I>

2

4

6

Protection of PVC-insulated cables against thermal overload on short-circuits
The table specifies which minimum conductor cross-sections are protected by motor-protective circuit-breaker PKZ(M) up to their
rated conditional short-circuit current Iq.

Min. cross-section protected
380 – 415 V, 50 Hz, Cu mm²
4

2.5

1.5

1

Device
Part no.
0.75
...

PKZM0-0,16
PKZM0-6.3
PKZM0-10
PKZM0-12
PKZM0-16
PKZM0-20
PKZM0-25
PKZM0-32
PKZM4-16
PKZM4-25
PKZM4-32
PKZM4-40
PKZM4-50
PKZM4-58
PKZM4-63

PKZM0-...T tripping characteristics (not for PKM0-...), PKZM01
2h
20

min

5

PKZM4-...

10
5

2

2

1
40

1
40

20
10

20
10

s

min
s

2h
20

PKZM0-...,
PKZM01

10

5

5
PKZM0...-T

2

2

1

1

200

200
20 x Iu

14 x I u
ms

14 x Iu
ms

1

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE

50
20

20

5

5

2

1.5

2

3

4

6

8 10

15

20

30

x Ir

30

50

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

2
1.5

2

3

4

6

8 10

15

20
x Ir

30

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE

1.3

t

h

Tripping characteristic curves, wide-range circuit-breaker PKE
2
1

1

PKE...

min

20
10
5
2
1

s

20
10
5
CLASS20
CLASS15
CLASS10
CLASS5

2
1
500
200

12 x Ir

ms

100
50

14 x Iu

20
10
5
2
1

1

1.5 2

3 4 5

7

10

15 20

30 40 50 70 100
x Ir

Let-through characteristics, motor-protective circuit-breaker, transformer-protective circuit-breakers,
circuit-breaker for starter combinations
i2dt 10 5
8
[A 2 s]
6
4
3

4.0 A

2
1
0.8
0.6

1.6 A

0.2

1A

10 A/12 A

2
1.5

6.3 A

10 4

2.5 A

0.4
0.3

PKZM01
PKZM0-.... 32 A
PKM0-.... 25 A
20 A
16 A

f-w
ave

32 A
25 A
20 A
16 A
10 A/12 A
6.3 A

10 PKZM0-....
8 PKZM01-....
6 PKM0-....
4
I cc
2·
3

1 st
hal

ÎD
[kA]

8
6

4.0 A

4
3
2
2.5 A

1.5

0.1
0.08
0.06

10 3
8
6

0.63 A

0.04
0.03

1.6 A

4
3

0.4 A

0.02

2

Ue = 400 V

0.015
0.01
1

1.5 2

3 4

6 8 10

15 20

30 40

Ue = 400 V

1.5

0.25 A

10 2

60 80100

1

1.5 2

3 4

6 8 10

Icc rms [kA]

15 20

1.0 A
30 40 60 80 100
Icc rms [kA]

Motor-protective circuit-breaker let-through characteristics
100

6
i2dt 10
[A 2 s]

PKZM4

1 st
hal
f

-w
ave

PKZM4

63/58 A
50/40/32 A
25 A
16 A

Ic

c

10 5
2·

ÎD
[kA]

63/58 A
50/40/32 A
25 A

10

10 4

16 A

10 3

Ue = 400 V

Ue = 400 V
1

10 2
1

10

100
Icc rms [kA]

1

10

100
Icc rms [kA]

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

31

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Switching capacity

Circuit-breaker switching capacity from serial no. 04
1 Rated uninterrupted current Iu
Rated conditional short-circuit current Iq IEC/EN 60947-4-1
Rated ultimate short-circuit breaking capacity Icu
IEC/EN 60947-2
Rated breaking capacity Ics

}

Iu
A

230 V
Iq
I cu
kA
kA

I cs
kA

A1)

400 V
Iq
I cu
kA
kA

I cs
kA

PKZM0, PKZM0...-T, PKM0 with type “1” and “2” coordination
150 150 150 N
150 150 150
0.16 – 1
1.6
150 150 150 N
150 150 150
2.5
150 150 150 N
150 150 150
4
150 150 150 N
150 150 150
6.3
150 150 150 N
150 150 150
10
150 150 150 N
150 150 150
12
50
50
13
50
50
50
13
16
50
50
13
50
50
50
13
20
50
50
13
50
50
50
13
25
50
50
13
50
50
50
13
32
50
50
13
50
50
50
13
PKZM0 (PKZM0...-T, PKM0) + CL-PKZ0
0.16 – 1
N
1.6
N
2.5
N
4
N
6.3
N
10
N
12
N
16
N
20
N
25
N
32
N
PKZM0 (PKZM0...-T, PKM0) + 2 CL-PKZ0
0.16 – 1
N
1.6
N
2.5
N
4
N
6.3
N
10
N
12
N
16
N
20
N
25
N
32
N
Notes

No upstream protective device
required, as it is the autoprotected range (100/150 kA)
N

32

A1)
N
N
N
N
N
N
50
50
50
50
50

440 V
Iq
I cu
kA
kA

42
15
15
10
10
10

42
15
15
10
10
10

I cs
kA

A1)

12
12
12
13
13
13

N
N
N
N
N
50
50
50
50
50
50

N
N
N
N
N
N
N
N
N
N
N

N
N
N
N
N
N
N
N
N
N
N

N
N
N
N
N
N
N
N
N
N
N

N
N
N
N
N
N
N
N
N
N
N
1)

500 V
Iq
I cu
kA
kA

42
42
15
15
6
6
6

10
10
10

20
20
20

42
42
15
15
6
6
6

10
10
10

20
20
20

I cs
kA

A1)

11
11
8
8
3
3
3

N
N
N
N
50
50
50
50
50
50
50

50
20
20
20
10
10
10

N
N
N
N
N
N
N
N
N
N
N

50
40
40
40
20
20
20

N
N
N
N
N
N
N
N
N
N
N

690 V
Iq
I cu
kA
kA

5
3
3
3
3
3
3
3
3

20
20
20
20
5
5
5
5
5

40
40
20
20
10
10
10
10
10

I cs
kA

A1)

5
3
3
3
3
3
3
3
3

5
3
2
2
2
2
1
1
1

N
N
50
50
50
50
50
50
50
50
50

20
20
20
20
5
5
5
5
5

20
20
20
20
20
20
2.5
2.5
2.5
2.5
2.5

N
N
N
N
N
N
N
N
N
N
N

40
40
20
20
10
10
10
10
10

20
20
20
20
20
20
2.5
2.5
2.5
2.5
2.5

N
N
N
N
N
N
N
N
N
N
N

Required back-up fuse if the short-circuit current exceeds the device's rated
conditional short-circuit current (Icc > I q ).

Not necessary

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Switching capacity

Circuit-breaker switching capacity
Rated uninterrupted current Iu
Rated conditional short-circuit current Iq IEC/EN 60947-4-1
Rated maximum short-circuit breaking capacity Icu
IEC/EN 60947-2
Rated breaking capacity Ics

1

}

Iu
A

230 V
Iq
I cu
kA
kA

I cs
kA

A1)

PKZM01 with type “1”and “2” coordination
0.16 – 1
50
50
50
50
1.6
50
50
50
50
2.5
50
50
50
50
4
50
50
50
50
6.3
50
50
50
50
10
50
50
50
50
12
50
50
10
50
16
50
50
10
50
20, 25
50
50
10
50
PKZM4 with type “1” and “2” coordination
150 150 25
N
16
25
150 150 25
N
32
50
50
25
100
40
50
50
25
100
50
50
50
25
100
58
50
50
25
160
63
50
50
25
160
PKE12...2) with type of coordination „1“ and
0.3 - 1.2
100
50
1-4
100
50
3 - 12
100
50
PKE32...2) with type of coordination „1“ and
3 - 12
100
50
8 - 32
100
50
Notes

A1)

440 V 2)
Iq
I cu
kA
kA

I cs
kA

A1)

50
50
50
50
50
50
10
10
10

50
50
50
50
50
50
50
50
50

50
50
50
50
50
42
15
15
10

50
50
50
50
50
42
15
15
10

50
50
50
50
50
10
10
10
3

50
50
50
50
50
50
50
50
50

25
25
25
25
25
25
25

N
N
100
100
100
160
160

45
45
45
45
45
45
45

45
45
45
45
45
45
45

25
25
25
25
25
25
25

100
100
100
100
100
160
160

15
15
15
15
15
15
15

100
100
100

50
50
50

50
50
15

50
50
50

100
100

50
50

15
25

50
50

400 V
Iq
I cu
kA
kA

I cs
kA

50
50
50
50
50
50
50
50
50

50
50
50
50
50
50
50
50
50

150
150
50
50
50
50
50

150
150
50
50
50
50
50

No upstream protective device
required,as it is the autoprotected range (150 kA)
N

Not necessary

500 V 2)
Iq
I cu
kA
kA

A 1)

690 V 2)
Iq
I cu
kA
kA

I cs
kA

A 1)

100
100
100
100
100
160
160

8
8
5
5
5
5
5

2.5
2.5
2.5
2.5
2.5
2.5
2.5

100
100
100
100
100
160
160

10
10
10

50
50
50

3
3
3

50
50
50

6
6

50
50

3
3

50
50

15
15
15
15
15
15
15

I cs
kA

8
8
5
5
5
5
5

1)

Fuse (A gG/gL) for increasing the switching capacity of the motor-protective
circuit-breaker to 100 kA

2)

Please enquire for additional information regarding voltages >400 V and
device combinations with CL-PKZ0.

Motor-protective circuit-breaker internal resistances
Impedance

PKZM0-0,16
PKZM0-0.25
PKZM0-0.4
PKZM0-0.63
PKZM0-1
PKZM0-1.6
PKZM0-2.5
PKZM0-4
PKZM0-6.3
PKZM0-10
PKZM0-12
PKZM0-16
PKZM0-20
PKZM0-25
PKZM0-32

Rated
uninterrupted
current Iu

Impedance

ȍ

Heat
dissipation
(3 pole at
operating
temperature)
W

A

78
32
13
5
2
0.8
0.32
0.13
0.050
0.020
0.014
0.008
0.005
0.003
0.002

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

0.16
0.25
0.4
0.63
1
1.6
2.5
4
6.3
10
12
16
20
25
32

PKZM4-16
PKZM4-25
PKZM4-32
PKZM4-40
PKZM4-50
PKZM4-58
PKZM4-63

Rated
uninterrupted
current Iu

ȍ

Heat
dissipation
(3 pole at
operating
temperature)
W

0.029
0.012
0.007
0.005
0.003
0.002
0.002

22
22
22
22
22
22
22

16
25
32
40
50
58
65

A

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

33

1.3
1

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Motor-protective circuit-breakers PKZM

Approvals for world markets
PKZM01, PKZM0, PKZM4
Rating data for approved types 1)
UL 508/CSA C 22.2 No. 14

Maximum motor rating

Setting ranges

Three-phase current
Overload
releases

200 V

230 V

460 V

575 V

HP

HP

HP

HP

A

Motor-protective circuit-breakers
“Manual Motor Starter with thermal and magnetic trip”
PKZM01
3)
PKZM01-0,16
0.1 – 0.16
PKZM01-0.25
0.16 – 0.25
PKZM01-0.4
0.25 – 0.4
PKZM01-0,63
0.4 – 0.63
PKZM01-1
0.63 – 1
PKZM01-1,6
¾
¾
1 – 1.6
PKZM01-2.5
½
½
1
1½
1.6 – 2,5
PKZM01-4
¾
¾
2
3
2.5 – 4
PKZM01-6,3
1
1½
3
5
4 – 6.3
PKZM01-10
3
3
7½
10
6.3 – 11
PKZM01-12
3
3
7½
10
9 – 12
PKZM01-16
3
5
10
10
10 – 16
PKZM01-20
5
15
16 – 20
PKZM01-25
7½
15
20
20 – 25
Motor-protective circuit-breakers
“Manual Motor Starter with thermal and magnetic trip”
PKZM01
3)
PKZM0-0,16
0.1 – 0.16
PKZM0-0.25
0.16 – 0.25
PKZM0-0.4
0.25 – 0.4
PKZM0-0.63
0.4 – 0.63
PKZM0-1
0.63 – 1
PKZM0-1.6
¾
¾
1 – 1.6
PKZM0-2.5
½
½
1
1½
1.6 – 2,5
PKZM0-4
¾
¾
2
3
2.5 – 4
PKZM0-6.3
1
1½
3
5
4 – 6.3
PKZM0-10
3
3
7½
10
6.3 – 11
PKZM0-12
3
3
7½
10
9 – 12
PKZM0-16
3
5
10
10
10 – 16
PKZM0-20
5
15
16 – 20
PKZM0-25
7½
15
20
20 – 25
PKZM0-32
7½
10
20
25
24 – 32
Motor-protective circuit-breakers
PKZM4
PKZM4-16
3
5
10
15
10 – 16
PKZM4-25
7½
7½
20
25
16 – 25
PKZM4-32
10
10
25
30
25 – 34
PKZM4-40
10
15
30
40
32 – 42
PKZM4-50
10
15
30
40
40 – 52
PKZM4-58
15
15
40
50
50 – 56
PKZM4-63
15
15
40
50
52 – 58
Notes
Service factor (SF)
Set value Ir , on the current scale, depending on the
load factor
SF = 1.15 J Ir = 1 x In mot
SF = 1 J Ir = 0.9 x In mot

34

Short-circuitreleases

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1)
2)
3)

Maximum protective device to UL/
CSA
Group protection 2)
Maximum
Maximum
Up to max.
fuse rating
circuit
short-circuit
breaker
current
600 V

with
CL

with
CL

A

kA

kA

A

2.2
3.4
5.6
8.8
14
22
35
56
88
140
168
224
280
350

50
50
50
50
50
50
50
50
50
22
18
10
10
10

50
50
50
18
18

600
600
600
600
600
600
600
600
600
150
150
150
150
150

2.2
3.4
5.6
8.8
14
22
35
56
88
140
168
224
280
350
448

50
50
50
50
50
50
50
50
50
22
18
10
10
10
10

50
50
50
18
18
18

600
600
600
600
600
600
600
600
600
150
150
150
150
150
150

with
CL

A

A

A

600
600
600
600
600

600
600
600
600
600
600
600
600
600
125
125
125
125
125

600
600
600
600
600

600
600
600
600
600
600

600
600
600
600
600
600
600
600
600
125
125
125
125
125
125

600
600
600
600
600
600

224
50
600
600
350
50
600
600
448
50
600
600
560
50
600
600
700
10
600
600
812
10
600
600
882
10
600
600
Devices for world markets IEC UL/CSA
Caution: Changed requirements for group protection
Calculate motor output in this range according to rated
operational current. Specified values as per NEC Table 430 – 150

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Type E starters

1.3

PKZM

1

Rating data for approved types1)
UL 508/CSA C 22.2 No. 14
Accessories
Standard auxiliary contacts

NHI11-PKZ0

Early-make auxiliary contacts
Trip indicators
Shunt release

Auxiliary contact for contact
module

For use with

Pilot Duty

General Use

PKZM0(-T)
PKZM4

A 600, Q 300

5 A – 600 V AC
1 A – 250 V DC

–

E150

0.5 A – 250 V AC

–

NHI12-PKZ0
NHI21-PKZ0
NHI2-11S-PKZ0
NHI-E-11-PKZ0
NHI-E-10-PKZ0
VHI20-PKZ0
VHI20-PKZ01
AGM2-10-PKZ0
AGM2-01-PKZ0
A-PKZ0(...)
U-PKZ0(...)

PKZM0(-T)
PKZM01
PKZM0(-T)
PKZM4

E150
E150
A 600, Q 300

0.5 A – 250 V AC
0.5 A – 250 V AC
5 A – 600 V AC
1 A – 250 V DC

–
–
–

PKZM0(-T)
PKZM4

–

–

HI11-S/EZ-PKZ0

PKZM0

A 600, Q 300

5 A – 600 V AC
1 A – 250 V DC

Actuating voltages and ordering
information
Products for the
German market
–

1)

Notes

Devices for world markets IEC UL/CSA

PKZM
Motor-protective circuit-breakers PKZM0(4) used as "Manual self-protected Motor Starters" – UL 508 Type E
Maximum motor output
Setting ranges
Interrupting Capacity =
AC
Short Circuit Current (SCCR)
200 V
230 V
460 V
575 V
Overload
Short-circuit
240 V
480Y/
600Y/
208 V
240 V
480 V
600 V
releases
releases
277 V 2)
347 V 2)

Motor
Protector

Accessories

[HP]

[HP]

[HP]

[HP]

[A]

[A]

[kA]

[kA]

[kA]

Part no.

Part no.

¾
1½
3
5
10
–
–
–
–
–
10
20
30
30
–
–
–

0.1 – 0.16
0.16 – 0.25
0.25 – 0.4
0.4 – 0.63
0.63 – 1
1 – 1.6
1.6 – 2,5
2.5 – 4
4 – 6.3
6.3 – 11
9 – 12
10 – 16
16 – 20
20 – 25
24 – 32
10 – 16
16 – 27
24 – 34
32 – 40
40 – 52
50 – 56
52 – 58

2.2
3.4
5.6
8.8
14
22
35
56
88
140
168
224
280
350
448
224
350
448
560
700
812
882

65
65
65
65
65
65
65
65
65
65
65
42
18
18
18
65
65
65
65
65
65
65

65
65
65
65
65
65
65
65
65
65
65
42
18
18
18
65
65
65
65
65
65
–

50
50
50
50
50
50
50
50
50
50
–
–
–
–
–
25
25
25
25
–
–
–

PKZM0-0.16
PKZM0-0.25
PKZM0-0.4
PKZM0-0.63
PKZM0-1
PKZM0-1.6
PKZM0-2.5
PKZM0-4
PKZM0-6.3
PKZM0-10
PKZM0-12
PKZM0-16
PKZM0-20
PKZM0-25
PKZM0-32
PKZM4-16
PKZM4-25
PKZM4-32
PKZM4-40
PKZM4-50
PKZM4-58
PKZM4-63

BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E

1)

½
¾
1
3
3
3
5
–
7½
3
5
7½
10
–
–
–
Notes

½
¾
1½
3
3
5
–
7½
10
5
7½
10
–
15
–
–

¾
1
2
3
7½
7½
10
–
15
20
10
15
20
30
30
40
40

Components

1)
2)

Calculate motor power in this range according to the rated current. Stated values to NEC Table 430 -150
Suitable for networks with grounded star-point

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

35

1.3

Motor-protective circuit-breaker

Technical data
PKZM, PKE
PKZM0-…1)

PKZM01…
General
Standards
Climatic proofing

IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Ambient temperature

Storage
Open

°C
°C

-25…80
-25…55

-25 …80
-25…55

Encapsulated

°C

-25…40

-25…40

°

90
°

°

90

Built-in position

90

1

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE

Direction of incoming supply
Degree of protection

Any
IP20

Any
IP20

IP00
Finger- and back-of-hand proof

IP00

AWG
mm²

25
max. 2000
1 x (1 - 6)
2 x (1 - 6)
1 x (1 - 6)
2 x (1 - 6)
18 - 10
–

mm²

–

AWG
Nm

–
1.7

25
max. 2000
1 x (1 - 6)
2 x (1 - 6)
1 x (1 - 6)
2 x (1 - 6)
18 - 10
1 x (1…2.5)
2 x (1…2.5)
1 x (1…2.5)
2 x (1…2.5)
18…14
1.7

Nm

1

1

U imp

V AC

Ue
Iu = I e

V AC
A

Operations
Operations
Operations/h

Hz
W
x 10 6
x 10 6
Ops/h

6000
III/3
690
16 or current setting of the
overcurrent release
40 - 60
6
0.05
0.05
25

6000
III/3
690
32 or current setting of the
overcurrent release
40 - 60
6
0.1
0.1
40

kA

60

Page 32
60 (up to PKZM0-16)
40 (PKZM0-20 to PKZM0-32)

AC-3 up to 690 V
DC-5 (up to 250 V)
Trip blocks
Temperature compensation

A
A

16
16 (3 contacts in series)

32
25 (3 contacts in series)

To IEC/EN 60947, VDE 0660
Operating range
Temperature compensation residual error for T > 40 °C
Setting range of overload releases

°C
°C
%/K
x Iu

-5…40
-25…55
̰0.25
0.6 - 1

-5…40
-25…55
̰0.25
0.6 - 1

Short-circuit releases tolerance
Phase-failure sensitivity

%

± 20
IEC/EN 60947-4-1,
VDE 0660 Part 102

± 20
IEC/EN 60947-4-1,
VDE 0660 Part 102

Device
Terminals

Contact protection to EN 50274
Shock resistance, half-sinusoidal shock, 10 ms to IEC 60068-2-27
I n s ta lla tio n a ltitu d e
Terminal capacity, screw terminals
Solid

Terminal capacity, spring-loaded terminals

Flexible with ferrule to
DIN 46228
Solid or stranded
Solid

Terminal screw tightening torque

Flexible with ferrule to
DIN 46228
Solid or stranded
Main conductors

Auxiliary conductors
Main contacts
Rated impulse withstand voltage
Overvoltage category/pollution degree
Rated operational voltage
Rated uninterrupted current = rated operational current
Rated frequency
Heat dissipation (3 pole at operating temperature)
Lifespan, mechanical
Lifespan, electrical (AC-3 at 400 V)
Maximum operating frequency
Short-circuit rating

g
m
mm²
mm²

AC
DC

Page 33

Motor switching capacity

Notes
36

1)

Tested according to IEC/EN 60947-1 (isolating characteristics) and IEC/EN 60947-2

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Motor-protective circuit-breaker

1.3
1

PKM0-…

PKZM0-…-T

PKZM4

PKE

IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
-25…80
-25…55

-25…40

-25…40

-25…40

-25…40
90

90

90
°

90

°

°

°

90

90

90

°

-25…70
-25…55

°

-25…80
-25…55

°

-25…80
-25…55

Any
IP20

Any
IP20

Any
IP20

Any
IP20

IP00
Finger- and back-of-hand proof

IP00

IP00

IP00

25
max. 2000
1 x (1 - 6)
2 x (1 - 6)
1 x (1 - 6)
2 x (1 - 6)
18 - 10
1 x (1…2.5)
2 x (1…2.5)
1 x (1…2.5)
2 x (1…2.5)
18…14
1.7

25
max. 2000
1 x (1 - 6)
2 x (1 - 6)
1 x (1 - 6)
2 x (1 - 6)
18 - 10
–

15
max. 2000
1 x (1 - 50)
2 x (1 - 35)
1 x (1 - 35)
2 x (1 - 35)
14 - 2
–

–

–

–
1.7

–
3.3

25
max. 2000
1 x (1 - 6)
2 x (1 - 6)
1 x (1 - 6)
2 x (1 - 6)
18 - 10
1 x (1…2.5)
2 x (1…2.5)
1 x (1…2.5)
2 x (1…2.5)
18…14
1.7

1

1

1

1

6000
III/3
690
32 or current setting of the
overcurrent release
40 - 60
6
0.1
0.1
40

6000
III/3
690
25 or current setting of the overcurrent release
40 - 60
6
0.1
0.1
40

6000
III/3
690
65 Open
63 enclosed
40 - 60
22
0.03
0.03
40

6000
III/3
690
32 A or set current
of the overcurrent release
40 - 60
6
0.05
0.05
60

Page 32
60 (up to PKM0-16)
40 (PKM0-20 to PKM0-32)

Page 32
60 (up to PKZM0-16)
40 (PKZM0-20 to PKZM0-32)

60

–

32
25 (3 contacts in series)

25
25 (3 contacts in series)

65
63 (3 contacts in series)

32
–

-5…40
-25…55
̰0.25

-5…40
-25…55
̰0.25
0.6 - 1

-5…40
-25…55
̰0.25
0.6 - 1

-5…40
-25…55

± 20
–

± 20
IEC/EN 60947-1-1,
VDE 0660 Part 102

± 20
IEC/EN 60947-4-1,
VDE 0660 Part 102

± 20
Yes

Page 33

Page 33

0.25 - 1

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

37

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Auxiliary contacts

1 NHI...PKZ, AGM, U-PKZ, A-PKZ
NHI…PKZ0

NHI-E-…PKZ0

VHI…PKZ0

AGM

Auxiliary contacts
Rated impulse withstand voltage
Overvoltage category/pollution degree
Rated operating voltage

U imp

V AC

6000
III/3

4000
III/3

4000
III/3

6000
III/3

Ue

V AC

500

440

440

500

Ue

V DC

250

250

250

250

V AC

690

690

690

690

Safe isolation according to EN 61140
Between auxiliary contacts and main contacts
Rated operational current
AC-15
220 - 240 V

Ie

A

3.5

1

1

3.5

380 - 415 V
440 - 500 V

Ie
Ie

A
A

2
1

–
–

–
–

2
1

24 V

Ie

A

2

2

2

2

60 V

Ie

A

1.5

–

–

1.5

110 V
220 V

Ie
Ie

A
A

1
0.25

–
–

–
–

1
0.25

Operations

x 10 6

> 0.1

> 0.1

> 0.1

> 0.01

Operations
Fault
probability

x 10 6

> 0.05

> 0.1

> 0.1

> 0.05

DC-13 L/R̰100 ms

Durability
Lifespan, mechanical
Lifespan, electrical
Control circuit reliability (at Ue = 24 V DC, Umin = 17 V,
I min = 5.4 mA)
Interlocked opposing contacts

< 10 -8 < 1 failure in 1 x 10 8 operations
Yes

–

–

–

A gG/gL

FAZ-B4/1-HI
10

–
10

–
10

FAZ-B4/1-HI
10

mm²
AWG

0.75 - 2.5
18 - 14

0.75 - 1.5
18 - 16

0.75 - 1.5
18 - 16

0.75 - 2.5
18 - 14

Short-circuit rating without welding
Fuseless
Fuse
Terminal capacity
Solid or flexible conductor with ferrule
Solid or stranded

NHI...PKZ, AGM, U-PKZ, A-PKZ
Undervoltage release
U-PKZ...

Shunt release
A-PKZ...

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
1 x (18 - 14)
2 x (18 - 14)

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
1 x (18 - 14)
2 x (18 - 14)

General
Terminal capacity
Solid or flexible conductor with ferrule

mm²

Solid or stranded

AWG

Main contacts
Rated operating voltage

Ue

V AC

42 - 480

42 - 480

Rated operating voltage

Ue

V DC

24 - 250

24 - 250

Pick-up-/drop-out voltage
Pick-up voltage

x Us

0.85 - 1.1

Drop-out voltage
Operating range

x Us

0.7 - 0.35

AC voltage

x Us

0.7…1.1

DC voltage (intermittent operation 5 s)
Power consumption

x Us

0.7…1.1

AC voltage
AC pick-up rating

Pick-up

VA

5

5

AC consumption when closed

Holding

VA

3

3

DC pick-up rating

Pick-up

W

–

3

DC consumption when closed

Holding

W

–

3

DC voltage

38

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Motor-protective circuit-breaker

Dimensions

1

Motor-protective circuit-breaker

45
93

PKZM01…

45

5.5

44
74
85

Motor-protective circuit-breaker
Transformer-protective circuit-breakers
Motor-protective circuit-breaker with
standard auxiliary contacts

Motor-protective circuit-breakers with
lockable rotary handles
PKZM0-…+AK-PKZ0

PKZM0-…(+NHI-E-…-PKZ0)
PKZM0-…-T(+NHI-E-…-PKZ0)
PKM0-…(+NHI-E-…-PKZ0)
70

93

45

45
55

93

4.5

AK-PKZ 0

AK-PKZ 0

NHI-E-..-PKZ0

45

NHI-E-..-PKZ0

25
45

88
94

Motor-protective circuit-breakers with
early-make auxiliary contacts

CL-PKZ…

PKZM0-…+VHI-…-PKZ0

45

80

93

73

93

45
28

55

Current limiters

90

50

50
68
76

VHI...-PKZ0
7.5

44
49.5

7.5

VHI...-PKZ0
70

50

45

68

Top-hat rail IEC/EN 60715

NHI…-PKZ0

AGM2…-PKZ0

A-PKZ0…
U-PKZ0…

9

9
68

26

18
68

45

90

45

90

45
26

36

Shunt release
Undervoltage release

36

Trip indicators

36

Standard auxiliary
contacts

90

86

49
68

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

39

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Busbar adapters

BBA2-63
BBA2-63/2TS

BBA4/2TS-L
BBA4L-63

45

10

60

10

72
35

35

BBA2-63/2TS
BBA2-63

63

63
10

55

BBA0/2TS-L
BBA0-25
BBA0-32

35

BBA4L-63
BBA4/2TS-L

BBA2-80/2TS-S

BBA2L-63
40
60
260

60

60

214

200

60

60

40

40

BBA4-63

63

60

BBA0-32/2TS-C
BBA0-25/2TS
BBA0C-16

60

260

60

60

200

200

60

60

40

40

BBA0-25/2TS
BBA0/2TS-L
BBA0-32
BBA0-32/2TS-C
BBA0C-16

40

1 BBA0-25

10

55

72

35

10
35

63

63

72

10
35
63

BBA0K-32

PKZM0-XC45L
PKZM0-XC45L-2

283

60

60

260

161

60

60

20

40

BBA0L-25
BBA0L-32

10

45
35
63

45

BBA0L-25
BBA0L-32

40

10
35
63

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

45

PKZM0-XC45L
PKZM0-XC45L-2

10
20
40

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Accessories

Insulated enclosures for surface mounting

1

70

158

CI-PKZ10G...M

158

CI-PKZ0-M

80

80

97.5
125.5

90
100

CI-PKZ0-…M
+ SVB-PKZ0-CI

Drilling dimensions
CI-PKZ0-…M
98

30
28

97.5

44

4.5

33

30

55

8

153

158

SVB-PKZ0-CI

4.5

80

47.5

100

181

160

181

CI-K2-PKZ0G(R)(V)

160

CI-K2-PKZ0

47.5

100

104

103
130

CI-K2-PKZ0-G(R)(V)
+ SVB-PKZ0-CI

Drilling dimensions
CI-K2-PKZ0…
98

30
114

28

M4

44

33

30

171

55

160
181

SVB-PKZ0-CI

97

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

M4

41

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Accessories

Door coupling handles
Mounting depth: 100 to 240 mm
from the top edge of the top-hat rail
to the front edge of the cabinet
door/cover
Distance between switch axis and
cover hinge: at least 100 mm

48

64

PKZ0-X(R)H…

7.5

64

20

54

48

At least 100 mm from cover hinge

IInsulated enclosures for flush mounting
E-PKZ0

Mounting aperture E-PKZ0…

E-PKZ0-G…

R4

116 – 118

55

129

69

80
96
124

85

70–72

E-PKZ0-G… + SVB-PKZ0-E
98

98
30

58

58

30

30

55

55

129

21

28

80

80

85
96

96

124

124

Insulated enclosures for surface mounting

Mounting plates

CI23E…

M3-CI23
142.5

3

3

147
177

35

144
147
177

56

7

114

225
262
278

62.5

205

162

knockout

60

200

90

114.5
84.5

114.5
84.5

14

215

92

92

14

8 x PG 16
2 x PG 21/29

125

25

250

187.5
25

27

27

1

6 × PG 16
1 × PG 21/29

42

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Accessories

Insulated enclosures for surface mounting
CI-PKZ01-SVB
CI-PKZ01-SVB-V

158
80

116.5

80

1

158

CI-PKZ01-PVT
CI-PKZ01-PVS

158

CI-PKZ01
CI-PKZ01-G

116.5

80
177.2

116.5
129.5

Insulated enclosures for flush mounting
E-PKZ01
E-PKZ01-G

E-PKZ01-PVT
E-PKZ01-PVS
69

129

129

69

90.2

90.2

93

93
115.2

115.2

175.9

E-PKZ01-SVB
E-PKZ01-SVB-V

129

69

90.2

93
115.2
128.2

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

43

1.3

Accessories

Motor-protective circuit-breaker

Standard auxiliary contacts

PKZM4-…

NHI…-PKZ…
NHI…-PKZ0

90

45

125

45

53

140

130

65

36

4

26

9

68

30

7.5

NHI-E...

NHI-E...
118

55

127
145
160

Motor-protective circuit-breakers with lockable cover

Tripindicators

PKZM4-… +AK-PKZ0

AGM2…-PKZ…
AGM2…-PKZ0

90

65
125

45

140

130

AK-PKZ0

45

36

4

9

26
68

7.5

30

118

55

127
145
171

PKE Motor-protective circuit-breakers
PKE12 , PKE32

PKE65
118

25

14.5

102.5
45

35

5.5
55

127
172
187

44

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

32.5

160

56.5

100.5

101

1

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Accessories

1.3

Three-phase commoning links
B3.2/4-PKZ4

1

14

14

36

36

B3.0/4-PKZ4

33

205

260

B3.2/2-PKZ4

14

14

36

36

B3.0/3-PKZ4

33

151

115

33

B3.0/3-PKZ4

14

14

36

36

B3.0/2-PKZ4

33

98

33

170

B3.1/2-PKZ4

14

14

36

36

B3.1/4-PKZ4

33

232

33

117

33

Three-phase commoning links

Three-phase commoning links

B3.0/4-PKZ0
B3.0/2-PKZ0

B3.2/4-PKZ0
B3.2/2-PKZ0
234

180 (90)

H-B3PKZ 0

H-B3PKZ0

27
45

27
63

Three-phase commoning links

Incomingterminals

B3.1/5-PKZ0
B3.1/4-PKZ0

BK25/3-PKZ0
Overlapping
mounting to
extend the
three-phase
commoning link

261 (207, 153, 99)

H-B3PKZ 0

̰ 56
31

BK25/3-PKZ0
48

27

7.5

73

B3.1/3-PKZ0
B3.1/2-PKZ0

54

̰ 41
B3...-PKZ0

62

94

Motor plug DILM12-XMCP/T

27

85
45

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

45

1.3

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE
Accessories

1 Insulated enclosures for surface mounting
CI-K4-PKZ4-G(R)
+SVB-PKZ4-CI

CI-K4-PKZ4-G
98

240

3

32

72

SVB-PKZ4-CI

160

134
181
197

Drilling dimensions
CI-K4-PKZ-G(R)

160

186

28
30

46

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

193

240

240

72

Ø 5.6

142

DC string circuit-breakers, DC switch-disconnectors

1.3

Description

1

P-SOL, PKZ-SOL, SOL

DC string circuit-breaker
PKZ-SOL
DC switch-disconnector
P-SOL
Ready-to-install DC switchdisconnector SOL
Inverter module
AC main switch
Network

Photovoltaics description

Features

Photovoltaic systems convert sunlight
directly into electrical energy using
solar cells. Photovoltaics represent a
renewable source of energy that can
be used on private and public
buildings, as well as in large-scale
power stations.
These systems can be independent
from the power grid or can be
connected to it. Photovoltaic systems
that are connected to the grid feed the
generated power directly into the
mains network. This eliminates the
need for temporary storage. These
systems consist of solar cells, one or
more inverters, and a protective
device for automatic cutoff in the
event of a grid fault. Because of this,
photovoltaic systems that are
connected to the grid require
extremely reliable and safe individual
components.

DC string circuit-breakers
• Protect PV modules from fault
currents, prevent (in larger systems,
for instance) intact modules from
feeding power back into a module
with a short-circuit.
• Are ready for operation immediately
after tripping and after the trip
cause has been fixed.
• Open and for installation in
customized generator terminal boxes.
• Tripping currents are adjustable
within a wide range of limits.
• Optional shunt releases A-PKZ0 and
undervoltage releases U-PKZ0
enable remote shutdown, e.g for the
fire department. Optional auxiliary
contact NHI-E-PKZ0 signals
switching state.
• When installed in an enclosure,
suitable for voltages of up to 900 VDC.
DC switch-disconnectors
• Required, according to standard
VDE 0100-712 (June 2006), between
the PV module and inverter.
• Enclosed and open (for installation
in enclosure) switch-disconnectors
for voltages of up to 1,000 VDC.
• Usable as a separate switching
point as required in VDI Guideline
VDI 6012, e.g. by de-energizing an
inverter in a completely safe
manner.

• Two-pole switching, making it
suitable for non-earthed systems as
well.
• TÜV-certified.
• Open switch-disconnectors P-SOL
are designed for installation in
customer-specific enclosures or
inverters.
• Mounting on 35 mm top-hat rails,
their terminals enable a connection
to all popular cable types.
• Separate rotary handles and shaft
extensions allow for flexible
installation.
• An auxiliary switching block can be
mounted in order to provide
switching state feedback.
• A shunt release or undervoltage
release is available for remote
tripping.
• Switch-disconnectors SOL with
enclosure are ready for installation.
Models for 2 and 4 or 4 and 8 strings
and for the most popular connector
types, such as MC3, MC4, and
metric screw connectors, allow for
easy integration into various system
concepts.
• Enclosure provides degree of
protection IP65, making outdoor
mounting possible.
• Lockable mechanism provides safety
when maintenance is required.
• Pressure-equalizing element
prevents the formation of condensed
water, preventing failures caused by
voltage sparkovers.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

47

1.3
1

DC string circuit-breakers, DC switch-disconnectors
DC switch-disconnectors, ready to install

Ordering
DC switch-disconnector, ready-to-install
Inputs
Number of
strings

Outputs
Connection type

Number of
strings

Connection type

Max. rated
operational current
DC-21A
Ie

Part no.
Article no.

Price
See price
list

Std. pack

A
Rated operational voltage Ue 1000 V
Degree of protection IP65
Protection class 2
2 pole
SOL20/2MC3
120913
SOL20/4MC3
120914

1 off

20

SOL20/2MC4
120915

1 off

MC4

20

1 off

1

Screw connector M16

20

SOL20/4MC4
120916
SOL20/2MV
120919

MC3

1

MC3

30

SOL30/2MC3
120920

1 off

4

MC3

1

MC3

30

1 off

2

MC4

1

MC4

30

SOL30/4MC3
120921
SOL30/2MC4
120922

4

MC4

1

MC4

30

SOL30/4MC4
120923

1 off

2

Screw connector M12

1

Screw connector M16

30

SOL30/2MV
120926

1 off

4

MC3

1

Screw connector M20

63

SOL60/4MC3
120927

1 off

8

MC3

1

Screw connector M20

63

SOL60/8MC3
120928

1 off

4

MC4

1

Screw connector M20

63

SOL60/4MC4
120929

1 off

8

MC4

1

Screw connector M20

63

SOL60/8MC4
120930

1 off

4

Screw connector M12

1

Screw connector M20

63

SOL60/4MV
120933

1 off

2

MC3

1

MC3

20

4

MC3

1

MC3

20

2

MC4

1

MC4

4

MC4

1

2

Screw connector M12

2

Information relevant for export to North America
NA Certification

48

Request filed for UL and CSA

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1 off

1 off

1 off

DC string circuit-breakers, DC switch-disconnectors

1.3

P-SOL, PKZ-SOL
Max. rated operational current
DC-21A
Ie
A

1
Permissible solar module
short-circuit currents

DC switch-disconnector, open
Rated operating voltage Ue 1000 V
Protection class II
2 pole
20

Part no.
Article no.

Price
See price list

Std. pack

P-SOL20
120934

1 off

30

P-SOL30
120935

1 off

63

P-SOL60
120936

1 off

DC string circuit-breakers
Rated operating voltage Ue 900 V
Protection class II
2 pole
12

5 - 9

PKZ-SOL12
120937

1 off

20

9 - 15

PKZ-SOL20
120938

1 off

30

15 - 22

PKZ-SOL30
120939

1 off

40

22 - 30

PKZ-SOL401)
120940

1 off

50

29 - 38

PKZ-SOL501)
120941

1 off

60

38 - 47

PKZ-SOL601)
120942

1 off

1)

Notes

Availability from November 2010

1
1
3
2

3

2

Accessories
2 Auxiliary contacts NHI-E
3 Shunt releases A-PKZ0
3 Undervoltage releases U-PKZ0

Page
10
29
29

Information relevant for export to North America
NA Certification

Request filed for UL and CSA
AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

49

1.3
1

DC string circuit-breakers, DC switch-disconnectors

Engineering
P-SOL and PKZ-SOL wiring
Switch-disconnector P-SOL
Non-earthed grid

String circuit-breaker PKZ-SOL
Non-earthed grid

Earthed grid

Earthed grid

1000 VDC

1000 VDC

900 VDC

900 VDC

1

3

5

1

3

5

1

3

5

1

3

5

2

4

6

2

4

6

2

4

6

2

4

6

SOL internal circuit
SOL20/2MV
SOL30/2MV

SOL20/2MC3
SOL20/2MC4
SOL30/2MC3
SOL30/2MC4
Input
+ Strings

1

Input (M12)
+ Strings

- Strings

3

5

1

3

4

6

2

Input

Input
+ Strings

- Strings

+ Strings

- Strings

- Strings

5

1
2

SOL60/4MC3
SOL60/4MC4

SOL20/4MC3
SOL20/4MC4
SOL30/4MC3
SOL30/4MC4

4

3

1

5

3

5

6

+

2

2
+

+

Output

4

+

SOL60/4MV

Input

Input (M12)
+ Strings

- Strings

1

3

5

+

2

4

6

+
Output (M20)

Output

SOL60/8MC3
SOL60/8MC4

+ Strings

- Strings

1

3

5

2

4

6

+

-

6

+
Output (M20)

50

4

6

Output (M16)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

+
Output (M20)

DC string circuit-breakers, DC switch-disconnectors
Characteristic curves

1.3

Tripping characteristics

1

Tripping characteristics
DC string circuit-breaker PKZ-SOL

t [s]

10.000
2h
1h
1.000

100
(1 min)

10

1

0.1

0.01

0.001

1

100
x Ir

10

Characteristic curve set value short-circuit current
As specified in the IEC 62548-1 draft for
the protection of photovoltaic modules,
the tripping current of the circuit-

breaker must lie between 1.4 and 2
times the value of the photovoltaic
module‘s short-circuit current.
Since only the current values of the
installed overload release can be
plotted on the setting scale for the

circuit-breaker1), the correlation
between the protective device‘s
tripping current and the photovoltaic
module‘s short-circuit current must be
specified for each point of the scale in
a suitable form.

Setting aid for string circuit-breaker PKZ-SOL

Ir 70
PKZ-SOL60

60

Set value on circuit-breaker [A]

50
PKZ-SOL50

40

PKZ-SOL40

30
20

PKZ-SOL30

PKZ-SOL20
PKZ-SOL12
PKZ-SOL7
PKZ-SOL4
0
0 5 10 15 20 25 30

10

35 40 45 50
ISC... [A]

Short-circuit current in solar module [A]
1) Standard IEC/EN 60947-2 (Section
4.7.3) prohibits directly specifying the
photovoltaic short-circuit current on
the circuit-breaker's setting scale,
meaning that only the current set value
of the operating current can be plotted
there.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

51

1.3

DC string circuit-breakers, DC switch-disconnectors
DC switch-disconnectors

Technical data
1 P-SOL, SOL
SOL20
Rated operational current Ie at DC-21A
Number of poles
Rated operational voltage U e
Isolating characteristics
Standards

A
V DC

Lifespan mechanical
Lifespan electrical
Max. operating frequency, mechanical
Climatic proofing

Operations
Operations

Ambient temperature
Mounting position
Degree of protection

min./max.

Ops/h

°C
IP

Dimensions
Width
Height
Depth
Weight
Lockable in OFF position
Rated short-time withstand current , 1 s to
EN 60947-3
Rated short-circuit making capacity to
EN 60947-3
Internal resistance

mm
mm
mm
kg

SOL30

SOL60

20
30
2
2
1000
1000
Yes
Yes
IEC/EN 60 947-3
UL 508, TÜV certificate
100,000
100,000
100,000
100,000
120
120
Damp heat, constant, to IEC 60 068-2-78
Damp heat, cyclic, to IEC 60 068-2-30
-25 ... +60
-25 ... +60
Any
Any
65
65

63
2
1000
Yes

100
215
130
0.42
Yes
0.36

160
305
210
2.2
Yes
0.72

30,000
30,000
120

-25 ... +60
Any
65

I cw

kA

100
215
130
0.42
Yes
0.24

I cm

kA

0.32

0.32

0.6

mȍ

8

7

4

P-SOL20

P-SOL30

P-SOL60

Ie

A

Ue

V DC

20
30
2
2
1000
1000
Yes
Yes
IEC/EN 60 947-3
UL 508, TÜV certificate
100,000
100,000
100,000
100,000
120
120
Damp heat, constant, to IEC 60 068-2-78
Damp heat, cyclic, to IEC 60 068-2-30

63
2
1000
Yes

°C

-25 ... +60
Any

-25 ... +60
Any

-25 ... +60
Any

mm
mm
mm

58
93
76

58
93
76

55
140
160

35 mm
–

35 mm
–

kg

0.32

0.32

35 mm
2 x M4 x 18
30 x 130
1.25

I cw

mm²
mm²
AWG
kA

1 x (1-6)
2 x (1-6)
18 - 14
0.24

1 x (1-6)
2 x (1-6)
18 - 14
0.36

1 x (1-35)
2 x (1-35)
14 - 2
0.72

I cm

kA

0.32

0.32

0.6

mȍ

6

5

3

P-SOL, SOL
Rated operational current at DC-21A
Number of poles
Rated operational voltage
Isolating characteristics
Standards
Lifespan mechanical
Lifespan electrical
Max. operating frequency, mechanical
Climatic proofing
Ambient temperature
Open
Mounting position
Dimensions
Width
Height
Depth
Mounting
Top-hat rail
Screw mounting

Operations
Operations
Ops/h

min./max.

Weight
Terminals
Flexible with ferrule
solid/stranded
Rated short-time withstand current , 1 s to
EN 60947-3
Rated short-circuit making capacity to
EN 60947-3
Internal resistance

52

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

30,000
30,000
120

1.3

DC string circuit-breakers, DC switch-disconnectors
DC string circuit-breakers, open

PKZ-SOL
PKZ-SOL12

PKZ-SOL20

PKZ-SOL30

PKZ-SOL40

PKZ-SOL50

PKZ-SOL60

20

30

40

50

63

Rated operational current at
DC-21A/750VDC
Number of poles

Ie

A

12
2

2

2

2

2

2

Rated operational voltage

Ue

V DC

900

900

900

900

900

900

-25 ... +60

-25 ... +60

-25 ... +60

Thermal tripping

1.05 ...1.3 x I e
6 x Ie

Electromagnetic tripping
Standards

IEC/EN 60 947-2
UL 508, TÜV certificate

Climatic proofing
Ambient temperature
Open

1

Damp heat, constant, to IEC 60 068-2-78
Damp heat, cyclic, to IEC 60 068-2-30
min./max.

°C

-25 ... +60

-25 ... +60

-25 ... +60

90
°

°

90

90

°

Mounting position

PKZ-SOL12
to PKZ-SOL60

PKZ-SOL12
to PKZ-SOL30

Dimensions
Width

mm

58

58

58

55

55

55

Height
Depth

mm
mm

93
76

93
76

93
76

140
160

140
160

140
160

Mounting
Top-hat rail

35 mm

35 mm

35 mm

35 mm

35 mm

35 mm

–

–

–

kg

0.32

0.32

0.32

2 x M4 x 18
30 x 130
1.25

2 x M4 x 18
30 x 130
1.25

2 x M4 x 18
30 x 130
1.25

mm²
mm²

1 x (1-6)

1 x (1-6)

1 x (1-6)

1 x (1-35)

1 x (1-35)

1 x (1-35)

2 x (1-6)
18 - 14
31

2 x (1-6)
18 - 14
12

2 x (1-6)
18 - 14
7

2 x (1-35)
14 - 2
–

2 x (1-35)
14 - 2
–

2 x (1-35)
14 - 2
–

Screw mounting
Weight
Terminals
flexible with ferrule
solid/stranded
Internal resistance

AWG
mȍ

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

53

1.3

DC string circuit-breakers, open

Dimensions
P-SOL, PKZ-SOL, SOL
P-SOL20
P-SOL30
PKZ-SOL12
PKZ-SOL20
PKZ-SOL30

P-SOL60
PKZ-SOL40
PKZ-SOL50
PKZ-SOL60

NHI-E...

58

43.5
62
5.5

30

NHI-E...

7.5
118

55

70

127
145
160

SOL

100

246

130.5

160

Connection
type

b
mm

Connection
type

b
mm

MC3
MC4
MV

195
234
224

MC3
MC4
MV

275
314
304

54

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

b

SOL60

b

SOL20
SOL30

215

125

45

53

130

140

65

92.5

45

4

180.3

1

DC switch-disconnectors, DC string circuit-breakers

1

Motor-starter combinations
Combining a motor protective circuit breaker or circuit breaker with a contactor results in
a motor starter according to coordination type "1" or "2". Both types of coordination safely
control short-circuit by switching it off. Coordination type "2" starters offer a high degree
of operational continuity: after the cause of the short circuit has been removed, they can
be switched back on immediately.
Motor-starter combination - motor starter up to 1400 A
• Highest safety through proven combination in coordination type "1" or "2"
• Approved combinations for export to North America
DOL starter and reversing starter MSC… – motor starter with motor-protective circuit-breaker
PKZM0 up to 32A
•
•
•
•

Mounted starters minimize wiring time
Plug & Play with starters on busbar adapters
Attractive design for high-quality installations
Direct field bus connection through SmartWire-DT® communication system via plug-in type
protective module

DOL starter and reversing starter MSC-DE… – motor starter with electric motor-protective
circuit-breaker PKE up to 32A
• Increased safety through separate contact systems between switching and safety devices
• Direct field bus connection through SmartWire-DT® communication system via plug-in type
protective module
• Direct reading of motor current and state, transfer to subordinate control system through
SmartWire-DT®
Conditions for fulfilling type of coordination
•
•
•
•
•
•
•
•

Coordination type: "1": Secure switching off of the entered short-circuit current lq
No danger to personnel or installations in case of short-circuit
For further operation without repair and partial renewal, switch does not need to be suitable
Damage to the switch or individual components approved
Coordination type: "2": Secure switching off of the entered short-circuit current lq
No danger to personnel or installations in case of short-circuit
Switch remains suitable for further operation
No damage to switch, except to welds of protective contacts, when these can be easily separated
without significant deformation

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Motor-starter combinations
Contents

Ordering
Direct-on-line starters MSC-D
MSC-D complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
MSC-US complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
MSC-DEA complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Modules PKZM0/PKZM4 + DILM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Modules NZMN/NZMH + DILM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Modules PKM0 + DILM + ZB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Modules NZMN + DILM + ZB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Ordering
Reversing starter MSC-R
MSC-R complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Modules PKZM0/PKZM4 + DILM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Modules NZMN/NZMH + DILM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Ordering
Starter on busbar adapter
DOL starter complete units MSC-D/BBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Reversing starters complete units MSC-R/BBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Ordering
Starter for North America
Modules type F starter combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Modules DILEM/DILM + ZE/ZB/Z5/ZW7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Modules NZMH-…-CNA + DILM + ZB/Z5/ZW7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
System overview, description
Connection system SmartWire-DT® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Ordering
Connection system SmartWire-DT® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Engineering
Connection system SmartWire-DT® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Technical data
Connection system SmartWire-DT® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
DOL starters MSC-D, MSC-DE(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Reversing starter MSC-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Dimensions
Direct-on-line starter MSC-D
MSC-D complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MSC-D/BBA complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MSC-DE(A) complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reversing starter MSC-R
MSC-R complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MSC-R/BBA complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connection system SmartWire-DT® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

39
39
40
40
40
41

1

1

1.4

Motor-starter combinations
Complete units

Ordering
1

MSC-D: PKZM0, DILM
Motor data

Motor rating

I

M
3~

Complete units MSC-D

Overload
trip

Part no.
Article no.

Rated short-circuit current

380 - 415 V

380 - 415 V

380 V
400 V
415 V
P

400 V

Type “1”
coordination

Type “2”
coordination

Ie

Iq

Iq

Ir

I rm

kW

A

kA

kA

A

A

0.06

0.21

150

50

0.16 - 0.25

3.5

Short-circuit
release

0.09

0.31

150

50

0.25 - 0.4

5.6

0.12
0.18

0.41
0.6

150

50

0.4 - 0.63

0.25

0.8

150

50

0.37
0.55
0.75

1.1
1.5
1.9

150

1.1
1.5
2.2

2.6
3.6
5

3

Price
See price
list

Std.
pack

I
MSC-D-0.25-M7(230V50Hz) 1)
281925
MSC-D-0.4-M7(230V50Hz) 1)
281926

1 off

8.82

MSC-D-0.63-M7(230V50Hz) 1)
281927

1 off

0.63 - 1

14

1 off

50

1 - 1.6

22.4

150

50

1.6 - 2.5

35

MSC-D-1-M7(230V50Hz) 1)
281929
MSC-D-1.6-M7(230V50Hz) 1)
283140
MSC-D-2.5-M7(230V50Hz) 1)
283142

150

50

2.5 - 4

56

1 off

150

50

4 - 6.3

88.2

MSC-D-4-M7(230V50Hz) 1)
283143
MSC-D-6.3-M7(230V50Hz) 1)
283145

6.6

150

–

6.3 - 10

140

1 off

4

8.5

150

–

6.3 - 10

140

MSC-D-10-M7(230V50Hz)
283146
MSC-D-10-M9(230V50Hz)
283147

5.5

11.3

50

–

8 - 12

168

MSC-D-12-M12(230V50Hz)
283148

1 off

7.5

15.2

50

–

10 - 16

224

MSC-D-16-M15(230V50Hz)
100414

1 off

3
4

6.6
8.5

50

50

6.3 - 10

140

MSC-D-10-M17(230V50Hz)
101045

1 off

5.5

11.3

50

50

8 - 12

168

MSC-D-12-M17(230V50Hz)
101046

1 off

7.5

15.2

50

50

10 - 16

224

1 off

11

21.7

50

50

20 - 25

350

MSC-D-16-M17(230V50Hz) 1)
283150
MSC-D-25-M25(230V50Hz) 1)
283151

15

29.3

50

50

25 - 32

448

MSC-D-32-M32(230V50Hz) 1)
283152

1 off

I

M
3~

2

Motor starters
actuating voltage
230 V 50 Hz

Rated
operational
current
AC-3

AC-3

Complete units MSC-D

Setting range

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1 off

1 off
1 off

1 off

1 off

1 off

Motor-starter combinations
Complete units

1.4
1

Motor starters
actuating voltage
24 V DC
Part no.
Article no.

Std.
pack

Motor
protective
circuit breaker

Contactor

Price
See price
list

DOL starter wiring
set

Notes

Mechanical connection module
and electrical
contact module

Type

Type

Type

MSC-D-0.25-M7(24VDC)1)
283154
MSC-D-0.4-M7(24VDC)1)
283155
MSC-D-0.63-M7(24VDC)1)
283156

1 off

PKZM0-0,25

DILM7-10(...)

PKZM0-XDM12

1 off

PKZM0-0,4

DILM7-10(...)

PKZM0-XDM12

1 off

PKZM0-0,63

DILM7-10(...)

PKZM0-XDM12

MSC-D-1-M7(24VDC)1)
283158

1 off

PKZM0-1

DILM7-10(...)

PKZM0-XDM12

MSC-D-1.6-M7(24VDC)1)
283159
MSC-D-2.5-M7(24VDC)1)
283161

1 off

PKZM0-1,6

DILM7-10(...)

PKZM0-XDM12

1 off

PKZM0-2,5

DILM7-10(...)

PKZM0-XDM12

MSC-D-4-M7(24VDC)1)
283162
MSC-D-6.3-M7(24VDC)1)
283164

1 off

PKZM0-4

DILM7-10(...)

PKZM0-XDM12

1 off

PKZM0-6,3

DILM7-10(...)

PKZM0-XDM12

MSC-D-10-M7(24VDC)
283165
MSC-D-10-M9(24VDC)
283166

1 off

PKZM0-10

DILM7-10(...)

PKZM0-XDM12

1 off

PKZM0-10

DILM9-10(...)

PKZM0-XDM12

MSC-D-12-M12(24VDC)
283167

1 off

PKZM0-12

DILM12-10(...)

PKZM0-XDM12

MSC-D-16-M15(24VDC)
100415

1 off

PKZM0-16

DILM15-10(...)

PKZM0-XDM12

MSC-D-10-M17(24VDC)
101047

1 off

PKZM0-10

DILM17-10(...)

PKZM0-XDM32

MSC-D-12-M17(24VDC)
101048

1 off

PKZM0-12

DILM17-10(...)

PKZM0-XDM32

MSC-D-16-M17(24VDC)
283168
MSC-D-25-M25(24VDC)
283169

1 off

PKZM0-16

DILM17-10(...)

PKZM0-XDM32

1 off

PKZM0-25

DILM25-10(...)

PKZM0-XDM32

MSC-D-32-M32(24VDC)
283170

1 off

PKZM0-32

DILM32-10(...)

PKZM0-XDM32

The DOL starters (complete devices) consist of a motor
protective circuit breaker PKZM0 and a contactor DILM.
With the adapterless top-hat rail mounting of starters up
to 15 A, only the motor-protective circuit-breaker on the
top-hat rail requires an adapter. The contactors are
provided with mechanical support via a mechanical
connection element.
Control wire guide with max. 6 conductors with up to 2.5
mm external diameter or 4 conductors up to 3.5 mm
external diameter.
From 16 A, the motor protective circuit breaker and
contactors are mounted on the top-hat rail adapter plate.
The connection of the main circuit between PKZ and
contactor is established with electrical contact modules.
When using auxiliary contacts DILA‐XHIT…
J Chapter 1.1 (Page 38) the electrical plugs can be
pulled without having to remove the front mounting
auxiliary contact.
Cannot be combined with NHI-E-...-PKZ0-C standard
auxiliary contact with spring-loaded terminal.

Further information
Technical data PKZM0
Accessories PKZ
Technical data DILM
Further actuating voltages
DILM accessories

Page
Chapter 1.3
Chapter 1.3 (Page 10)
Chapter 1.1
Chapter 1.1 (Page 69)
Chapter 1.1 (Page 50)

1)

To assemble Type F starters that conform with
UL508, incoming terminals BK25/3-PKZ0-E and, if
necessary, three-phase terminal blocks B3.../...-PKZ0
can be added to motor starter combinations. Type F
starter
Page 28

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

3

1.4

Motor-starter combinations
Complete units 400/415 V

MSC-DE: PKE, DILM

1

Motor data

Complete units MSC-US

I

M
3~

Complete units MSC-US

Setting range

Rated
operational
power
AC-3

Rated
operational
current
AC-3

Rated shortcircuit
current

380 V
400 V
415 V
P

400 V

380 - 415 V

Ie

kW

A

0.06

0.21

0.09

Overload
trip

Shortcircuit
release

Iq

Ir

I rm

kA

A

A

100

0.3 - 1.2

16.8

"1"

0.31

100

0.3 - 1.2

16.8

"1"

0.12

0.41

100

0.3 - 1.2

16.8

"1"

0.18

0.6

100

0.3 - 1.2

16.8

"1"

0.25

0.8

100

0.3 - 1.2

16.8

"1"

0.37

1.1

100

0.3 - 1.2

16.8

"1"

0.55

1.5

100

1-4

56

"1"

0.75

1.9

100

1-4

56

"1"

1.1

2.6

100

1-4

56

"1"

1.5

3.6

100

1-4

56

"1"

2.2

5

100

3 - 12

168

"1"

3

6.6

100

3 - 12

168

"1"

4

8.5

100

3 - 12

168

"1"

5.5

11.3

100

3 - 12

168

"1"

2.2

5

100

3 - 12

168

"1", "2"

3

6.6

100

3 - 12

168

"1", "2"

4

8.5

100

3 - 12

168

"1", "2"

5.5

11.3

100

3 - 12

168

7.5

16.7

100

8 - 32

11

21.7

100

15

29.3

100

Std.
pack
Price
See price
list

I
MSC-DE-1.2-M7(230V50Hz)
121735
MSC-DE-1.2-M7(230V50Hz)
121735
MSC-DE-1.2-M7(230V50Hz)
121735
MSC-DE-1.2-M7(230V50Hz)
121735
MSC-DE-1.2-M7(230V50Hz)
121735
MSC-DE-1.2-M7(230V50Hz)
121735
MSC-DE-4-M7(230V50Hz)
121737

1 off

MSC-DE-4-M7(230V50Hz)
121737
MSC-DE-4-M7(230V50Hz)
121737
MSC-DE-4-M7(230V50Hz)
121737

1 off

MSC-DE-12-M7(230V50Hz)
121739
MSC-DE-12-M7(230V50Hz)
121739
MSC-DE-12-M9(230V50Hz)
121741

1 off

MSC-DE-12-M12(230V50Hz)
121743
MSC-DE-12-M17(230V50Hz)
121745
MSC-DE-12-M17(230V50Hz)
121745
MSC-DE-12-M17(230V50Hz)
121745

1 off

"1", "2"

MSC-DE-12-M17(230V50Hz)
121745

1 off

448

"1", "2"

1 off

8 - 32

448

"1", "2"

8 - 32

448

"1", "2"

MSC-DE-32-M17(230V50Hz)
121747
MSC-DE-32-M25(230V50Hz)
121749
MSC-DE-32-M32(230V50Hz)
121751

I

M
3~

4

Type of
coordination

Motor starters
actuating voltage
230 V 50 Hz
Part no.
Article no.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1 off
1 off
1 off
1 off
1 off
1 off

1 off
1 off

1 off
1 off

1 off
1 off
1 off

1 off
1 off

Motor-starter combinations
Complete units 400/415 V

1.4
1

Motor starters
actuating voltage
24 V DC
Part no.
Article no.

Std.
pack

Motor
protective
circuit breaker

Contactor

Price
See price
list

DOL starter
wiring set

Notes

Mechanical connection module
and electrical
contact module

Type

Type

Type

MSC-DE-1.2-M7(24VDC)
121736
MSC-DE-1.2-M7(24VDC)
121736
MSC-DE-1.2-M7(24VDC)
121736
MSC-DE-1.2-M7(24VDC)
121736
MSC-DE-1.2-M7(24VDC)
121736
MSC-DE-1.2-M7(24VDC)
121736

1 off

PKE12/XTU-1.2

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTU-1.2

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTU-1.2

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTU-1.2

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTU-1.2

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTU-1.2

DILM7-10(...)

PKZM0-XDM12

MSC-DE-4-M7(24VDC)
121738

1 off

PKE12/XTU-4

DILM7-10(...)

PKZM0-XDM12

MSC-DE-4-M7(24VDC)
121738
MSC-DE-4-M7(24VDC)
121738
MSC-DE-4-M7(24VDC)
121738

1 off

PKE12/XTU-4

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTU-4

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTU-4

DILM7-10(...)

PKZM0-XDM12

MSC-DE-12-M7(24VDC)
121740

1 off

PKE12/XTU-12

DILM7-10(...)

PKZM0-XDM12

MSC-DE-12-M7(24VDC)
121740
MSC-DE-12-M9(24VDC)
121742
MSC-DE-12-M12(24VDC)
121744
MSC-DE-12-M17(24VDC)
121746
MSC-DE-12-M17(24VDC)
121746

1 off

PKE12/XTU-12

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTU-12

DILM9-10(...)

PKZM0-XDM12

1 off

PKE12/XTU-12

DILM12-10(...)

PKZM0-XDM12

1 off

PKE12/XTU-12

DILM17-10(...)

PKZM0-XDM32

1 off

PKE12/XTU-12

DILM17-10(...)

PKZM0-XDM32

MSC-DE-12-M17(24VDC)
121746
MSC-DE-12-M17(24VDC)
121746

1 off

PKE12/XTU-12

DILM17-10(...)

PKZM0-XDM32

1 off

PKE12/XTU-12

DILM17-10(...)

PKZM0-XDM32

MSC-DE-32-M17(24VDC)
121748
MSC-DE-32-M25(24VDC)
121750
MSC-DE-32-M32(24VDC)
121752

1 off

PKE32/XTU-32

DILM17-10(...)

PKZM0-XDM32

1 off

PKE32/XTU-32

DILM25-10(...)

PKZM0-XDM32

1 off

PKE32/XTU-32

DILM32-10(...)

PKZM0-XDM32

The DOL starters (complete devices) consist of a PKE
motor protective circuit breaker and a DILM contactor.
With the adapterless top-hat rail mounting of starters up
to 15 A, only the motor protective circuit breaker on the
top-hat rail requires an adapter.
The contactors are provided with mechanical support via
a mechanical connection element.
Control wire guide with max. 6 conductors with up to
2.5 mm external diameter or 4 conductors up to 3.5 mm
external diameter.
From 16 A, the motor protective circuit breaker and
contactor are mounted on the top-hat rail adapter plate.
The connection of the main circuit between PKE and
contactor is established with electrical contact modules.
When using auxiliary contacts DILA-XHIT…
J Chapter 1.1 (Page 38) the electrical plugs can be
pulled without having to remove the front mounting
auxiliary contact.
Cannot be combined with standard auxiliary contact
NHI-E-...-PKZ0-C with spring-loaded terminals.
Further information
Technical data PKE
Accessories PKE
Technical data DILM
Further actuating voltages
DILM accessories

Page
Chapter 1.3
Chapter 1.3 (Page 10)
Chapter 1.1
Chapter 1.1 (Page 69)
Chapter 1.1 (Page 50)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

5

1.4

Motor-starter combinations
Complete units 400/415 V

MSC-DEA: PKE, DILM

1

Motor data

Complete devices MSD-DEA

I

M
3~

Complete devices MSD-DEA

Setting range

Rated operational
power
AC-3

Rated operational
current
AC-3

Rated short-circuit
current

380 V
400 V
415 V
P

400 V

380 - 415 V

Ie

Iq

Ir

I rm

kW

A

kA

A

A

0.06

0.21

100

0.3 - 1.2

16.8

"1"

0.09

0.31

100

0.3 - 1.2

16.8

"1"

0.12

0.41

100

0.3 - 1.2

16.8

"1"

0.18

0.6

100

0.3 - 1.2

16.8

"1"

0.25

0.8

100

0.3 - 1.2

16.8

"1"

0.37

1.1

100

0.3 - 1.2

16.8

"1"

0.55

1.5

100

1-4

56

"1"

0.75

1.9

100

1-4

56

"1"

1.1

2.6

100

1-4

56

"1"

1.5

3.6

100

1-4

56

"1"

2.2

5

100

3 - 12

168

"1"

3

6.6

100

3 - 12

168

"1"

4

8.5

100

3 - 12

168

"1"

5.5

11.3

100

3 - 12

168

"1"

2.2

5

100

3 - 12

168

"1", "2"

3

6.6

100

3 - 12

168

"1", "2"

4

8.5

100

3 - 12

168

"1", "2"

5.5

11.3

100

3 - 12

168

"1", "2"

7.5

16.7

100

8 - 32

448

"1", "2"

11

21.7

100

8 - 32

448

"1", "2"

15

29.3

100

8 - 32

448

"1", "2"

I

M
3~

6

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Overload trip

Short-circuit release

Type of
coordination

I

Motor-starter combinations
Complete units 400/415 V

1.4
1

Motor starters
actuating voltage
24 V DC
Part no.
Article no.

Std.
pack

Motor
protective
circuit breaker

Contactor

Price
See price
list

DOL starter
wiring set
Mechanical connection module
and electrical
contact module

Type

Type

Type

1 off

PKE12/XTUA-1.2

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTUA-1.2

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTUA-1.2

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTUA-1.2

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTUA-1.2

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTUA-1.2

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTUA-4

DILM7-10(...)

PKZM0-XDM12

MSC-DEA-4-M7(24VDC)
121754
MSC-DEA-4-M7(24VDC)
121754
MSC-DEA-4-M7(24VDC)
121754
MSC-DEA-12-M7(24VDC)
121755
MSC-DEA-12-M7(24VDC)
121755

1 off

PKE12/XTUA-4

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTUA-4

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTUA-4

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTUA-12

DILM7-10(...)

PKZM0-XDM12

1 off

PKE12/XTUA-12

DILM7-10(...)

PKZM0-XDM12

MSC-DEA-12-M9(24VDC)
121756

1 off

PKE12/XTUA-12

DILM9-10(...)

PKZM0-XDM12

MSC-DEA-12-M12(24VDC)
121757
MSC-DEA-12-M17(24VDC)
121758
MSC-DEA-12-M17(24VDC)
121758
MSC-DEA-12-M17(24VDC)
121758
MSC-DEA-12-M17(24VDC)
121758

1 off

PKE12/XTUA-12

DILM12-10(...)

PKZM0-XDM12

1 off

PKE12/XTUA-12

DILM17-10(...)

PKZM0-XDM32

1 off

PKE12/XTUA-12

DILM17-10(...)

PKZM0-XDM32

1 off

PKE12/XTUA-12

DILM17-10(...)

PKZM0-XDM32

1 off

PKE12/XTUA-12

DILM17-10(...)

PKZM0-XDM32

MSC-DEA-32-M17(24VDC)
121759
MSC-DEA-32-M25(24VDC)
121760
MSC-DEA-32-M32(24VDC)
121761

1 off

PKE32/XTUA-32

DILM17-10(...)

PKZM0-XDM32

1 off

PKE32/XTUA-32

DILM25-10(...)

PKZM0-XDM32

1 off

PKE32/XTUA-32

DILM32-10(...)

PKZM0-XDM32

MSC-DEA-1.2-M7(24VDC)
121753
MSC-DEA-1.2-M7(24VDC)
121753
MSC-DEA-1.2-M7(24VDC)
121753
MSC-DEA-1.2-M7(24VDC)
121753
MSC-DEA-1.2-M7(24VDC)
121753
MSC-DEA-1.2-M7(24VDC)
121753
MSC-DEA-4-M7(24VDC)
121754

Notes

The DOL starters (complete devices) consist of a PKE
motor protective circuit breaker and a DILM contactor.
With the adapterless top-hat rail mounting of starters up
to 15 A, only the motor protective circuit breaker on the
top-hat rail requires an adapter.
The contactors are provided with mechanical support via
a mechanical connection element.
Control wire guide with max. 6 conductors with up to
2.5 mm external diameter or 4 conductors up to 3.5 mm
external diameter.
From 16 A, the motor protective circuit breaker and
contactor are mounted on the top-hat rail adapter plate.
The connection of the main circuit between PKE and
contactor is established with electrical contact modules.
When using auxiliary contacts DILA‐XHIT…
J Chapter 1.1 (Page 38) the electrical plugs can be
pulled without having to remove the front mounting
auxiliary contact.
Cannot be combined with standard auxiliary contact
NHI-E-...-PKZ0-C with spring-loaded terminals.
The DOL starters MSC-DEA... are prepared for
communication via SmartWire-DT®. For this the SWD-PKE
communication must be added.
Further information
Technical data PKE
Accessories PKE
Technical data DILM
Further actuating voltages
DILM accessories

Page
Chapter 1.3
Chapter 1.3 (Page 10)
Chapter 1.1
Chapter 1.1 (Page 69)
Chapter 1.1 (Page 50)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

7

1.4

Motor-starter combinations
Modules

PKZM, DILM

1

Motor data

Modules PKZM0 and DILM

Setting range

Rated operational power

Rated operational current

Overload trip

Short-circuit
release

AC-3

AC-3

380 - 415 V

380 - 415 V

380 V
400 V
415 V
P

400 V

Type “1”
coordination

Type “2”
coordination

Ie

Iq

kW

A

kA

Iq

Ir

I rm

kA

A

A

0.06
0.09
0.12

0.21
0.31
0.41

150
150
150

50
50
50

0.16 - 0.25
0.25 - 0.4
0.4 - 0.63

3.5
5.6
8.82

0.18

0.6

0.25

0.8

150

50

0.4 - 0.63

8.82

150

50

0.63 - 1

0.37
0.55

14

1.1
1.5

150
150

50
50

1 - 1 .6
1 - 1 .6

22.4
22.4

0.75

1.9

150

50

1.6 - 2.5

35

1.1

2.6

150

50

2.5 - 4

56

1.5

3.6

150

50

2.5 - 4

56

2.2

5

150

50

4 - 6.3

88.2

3
4

6.6
8.5

150
150

50
50

6.3 - 10
6.3 - 10

140
140
168

5.5

11.3

50

50

8 - 12

7.5

15.2

50

50

10 - 16

224

11
15

21.7
29.3

50
50

50
50

20 - 25
25 - 32

350
448

5.5

11.3

50

50

10 - 16

224

7.5

15.2

50

50

10 - 16

224

11

21.7

50

50

20 - 25

350

15

29.3

50

50

25 - 32

448

18.5
22

36
41

50
50

50
50

32 - 40
40 - 50

560
700

30
34

55
63

50
50

50
50

50 - 58
55 - 65

812
882

M
3~

Modules PKZM4 and DILM

M
3~

8

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

I

Motor-starter combinations
Modules

1.4
1

Motor protective
circuit breaker

Contactor

Contactor

Type “1”
coordination

Type “2”
coordination

Type

Type

Type

PKZM0-0,25
PKZM0-0,4

DILM7-…(…)
DILM7-…(…)

DILM7-…(…)
DILM7-…(…)

PKZM0-0,63

DILM7-…(…)

DILM7-…(…)

PKZM0-0,63

DILM7-…(…)

DILM7-…(…)

PKZM0-1

DILM7-…(…)

DILM7-…(…)

PKZM0-1,6

DILM7-…(…)

DILM7-…(…)

PKZM0-1,6

DILM7-…(…)

DILM7-…(…)

PKZM0-2,5
PKZM0-4

DILM7-…(…)
DILM7-…(…)

DILM7-…(…)
DILM7-…(…)

PKZM0-4

DILM7-…(…)

DILM7-…(…)

PKZM0-6,3
PKZM0-10

DILM7-…(…)
DILM7-…(…)

DILM7-…(…)
DILM17-…(…)

PKZM0-10

DILM9-…(…)

DILM17-…(…)

PKZM0-12
PKZM0-16

DILM12-…(…)
DILM15-…(…)

DILM17-…(…)
DILM17-…(…)

PKZM0-25
PKZM0-32

DILM25-…(…)
DILM32-…(…)

DILM25-…(…)
DILM32-…(…)

PKZM4-16

DILM17-…(…)

DILM17-…(…)

PKZM4-16

DILM17-…(…)

DILM17-…(…)

PKZM4-25
PKZM4-32

DILM25-…(…)
DILM32-…(…)

DILM25-…(…)
DILM32-…(…)

PKZM4-40

DILM40(…)

DILM40(…)

PKZM4-50

DILM50(…)

DILM50(…)

PKZM4-58
PKZM4-63

DILM65(…)
DILM65(…)

DILM65(…)
DILM65(…)

Notes

The motor-starter combinations consist of the motor protective circuit breaker
or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or
VDE 0660 Part 102.
I q = conditional rated current

Further information
Technical data PKZM0
Accessories PKZ
Technical data DILM
Further actuating voltages
DILM accessories

Page
Chapter 1.3
Chapter 1.3 (Page 10)
Chapter 1.1
Chapter 1.1 (Page 69)
Chapter 1.1 (Page 50)

The motor-starter combinations consist of the motor protective circuit breaker
or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or
VDE 0660 Part 102.
I q = conditional rated current

Further information
Technical data PKZM4
Accessories PKZ
Technical data DILM
Further actuating voltages
DILM accessories

Page
Chapter 1.3
Chapter 1.3 (Page 10)
Chapter 1.1
Chapter 1.1 (Page 70)
Chapter 1.1 (Page 50)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

9

1.4

Motor-starter combinations
Modules

PKZM, DILM

1

Motor data

Modules PKZM0 and DILM

M
3~

Modules PKZM4 and DILM

Setting range

Rated operational
power
AC-3

Rated operational
current
AC-3

Rated short-circuit current
500 V

500 V

500 V

500 V

Type “1” coordination

Type “2” coordination

P

Ie

Iq

Iq

kW

A

kA

kA

0.06

0.17

100

50

0.16 - 0.25

3.5

0.09

0.25

100

50

0.25 - 0.4

5.6

0.12
0.18

0.33
0.48

100
100

50
50

0.25 - 0.4
0.4 - 0.63

5.6
8.8

0.25

0.7

100

50

0.63 - 1

14

0.37
0.55

0.9
1.2

100
100

50
50

0.63 - 1
1 - 1.6

14
22

Ir
A

Short-circuit
release

I rm
A

0.75

1.5

100

50

1 - 1.6

22

1.1
1.5

2.1
2.9

100
100

50
50

1.6 - 2.5
2.5 - 4

35
56

2.2

4

42

18

4 - 6.3

88

2.2

4

–

50

4 - 6.3

88

3

5.3

42

18

4 - 6.3

88

3
4

5.3
6.8

–
42

50
18

4 - 6.3
6.3 - 10

88
140

4
5.5

6.8
9

–
42

50
18

6.3 - 10
6.3 - 10

140
140

5.5
6.5

9
10.6

–
42

50
18

6.3 - 10
8 - 12

140
168

6.5

10.6

–

50

8 - 12

168

7.5
7.5

12.1
12.1

15
–

18
50

10 - 16
10 - 16

224
224

11

17.4

6

–

16 - 20

280

11

17.4

15

–

16 - 20

280

15
15

23.4
23.4

6
15

–
–

20 - 25
20 - 25

350
350

18.5

28.9

6

–

25 - 32

448

18.5
11

28.9
17.4

15
50

–
50

25 - 32
16 - 25

448
350

15

23.4

50

50

16 - 25

350

18.5

28.9

50

50

25 - 32

448

22

33

50

50

32 - 40

560

30

44

50

50

40 - 50

700

37
45

54
65

50
50

50
50

50 - 58
55 - 65

812
882

M
3~

10

Overload trip

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

I

Motor-starter combinations
Modules

1.4
1

Motor protective circuit
breaker

Contactor

Contactor

Current limiter

Type “1” coordination

Type “2” coordination

Type

Type

Type

Type

PKZM0-0,25
PKZM0-0,4

DILM7-…(…)
DILM7-…(…)

DILM7-…(…)
DILM7-…(…)

–
–

PKZM0-0,4

DILM7-…(…)

DILM7-…(…)

–

PKZM0-0,63
PKZM0-1

DILM7-…(…)
DILM7-…(…)

DILM7-…(…)
DILM7-…(…)

–
–

PKZM0-1

DILM7-…(…)

DILM7-…(…)

–

PKZM0-1,6

DILM7-…(…)

DILM7-…(…)

–

PKZM0-1,6

DILM7-…(…)

DILM7-…(…)

–

PKZM0-2,5
PKZM0-4

DILM7-…(…)
DILM7-…(…)

DILM17-…(…)
DILM17-…(…)

–
–

Notes

The motor-starter combinations consist of the motor protective
circuit breaker or a circuit breaker and a contactor.
They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102.
I q = rated conditional short-circuit current.
Further information
Technical data PKZM...
PKZM accessories...
Technical data DILM
Further actuating voltages
DILM accessories

PKZM0-6,3

DILM7-…(…)

DILM17-…(…)

–

PKZM0-6,3

–

DILM17-…(…)

CL-PKZ0

PKZM0-6,3

DILM7-…(…)

DILM17-…(…)

–

PKZM0-6,3
PKZM0-10

–
DILM9-…(…)

DILM17-…(…)
DILM17-…(…)

CL-PKZ0
–

PKZM0-10
PKZM0-10

–
DILM9-…(…)

DILM17-…(…)
DILM17-…(…)

CL-PKZ0
–

PKZM0-10
PKZM0-12

–
DILM12-…(…)

DILM17-…(…)
DILM17-…(…)

CL-PKZ0
–

PKZM0-12

–

DILM17-…(…)

CL-PKZ0

PKZM0-16
PKZM0-16

DILM17-…(…)
–

DILM17-…(…)
DILM17-…(…)

–
CL-PKZ0

PKZM0-20

DILM25-…(…)

–

–

PKZM0-20

DILM25-…(…)

–

CL-PKZ0

PKZM0-25
PKZM0-25

DILM25-…(…)
DILM25-…(…)

–
–

–
CL-PKZ0

PKZM0-32

DILM32-…(…)

–

–

PKZM0-32
PKZM4-25

DILM32-…(…)
DILM40(…)

–
DILM40(…)

CL-PKZ0
–

PKZM4-25

DILM40(…)

DILM40(…)

–

PKZM4-32

DILM40(…)

DILM40(…)

–

PKZM4-40

DILM40(…)

DILM40(…)

–

PKZM4-50

DILM50(…)

DILM50(…)

–

PKZM4-58
PKZM4-63

DILM65(…)
DILM65(…)

DILM65(…)
DILM65(…)

–
–

Page
Chapter 1.3
Chapter 1.3 (Page 10)
Chapter 1.1
Chapter 1.1 (Page 71)
Chapter 1.1 (Page 52)

The motor-starter combinations consist of the motor protective
circuit breaker or a circuit breaker and a contactor.
They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102.
I q = rated conditional short-circuit current.
Further information
Technical data PKZM...
PKZM accessories...
Technical data DILM
Further actuating voltages
DILM accessories

Page
Chapter 1.3
Chapter 1.3 (Page 10)
Chapter 1.1
Chapter 1.1 (Page 71)
Chapter 1.1 (Page 52)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

11

1.4

Motor-starter combinations
Modules

NZMN, NZMH, DILM

1

Motor data

Modules NZMN and DILM

Setting range

Rated operational power

Rated operational current

AC-3

AC-3

380 V
400 V
415 V
P

400 V

Ie

kW

A

18.5
22

36
41

30
37

Rated short-circuit current

Overload trip

Short-circuit
release

Iq

Ir

I rm

kA

A

A

50
50

32 - 40
40 - 50

320 - 560
400 - 700

55

50

50 - 63

504 - 882

68

50

63 - 80

640 - 1120

45

81

50

80 - 100

800 - 1250

55

99

50

80 - 100

800 - 1250

75

134

50

125 - 160

1280 - 2240

90
110

161
196

50
50

160 - 200
160 - 200

1600 - 2500
1600 - 2500

132

231

50

175 - 350

350 - 4900

160

279

50

175 - 350

350 - 4900

200
250

349
437

50
50

175 - 350
225 - 450

350 - 4900
450 - 6300

315

544

50

275 - 550

550 - 7700

400
450

683
750

50
50

438 - 875
438 - 875

875 - 12250
875 - 12250

500
560

820
947

50
50

438 - 875
700 - 1400

875 - 12250
1400 -19600

400/415 V

I

M
3~
Modules NZMH and DILM

22

41

100

40 - 50

400 - 700

30
37

55
68

100
100

50 - 63
63 - 80

504 - 882
640 - 1120

45

81

100

80 - 100

800 - 1250

55

100

100

100 - 125

1000 - 1750

75

134

100

125 - 160

1280 - 2240

30
37

55
68

100
100

45 - 90
45 - 90

90 - 1260
90 - 1260

45

81

100

45 - 90

90 - 1260

55
75

100
134

100
100

70 - 140
70 - 140

140 - 1960
140 - 1960

90

161

100

110 - 120

220 - 3080

110

196

100

110 - 120

220 - 3080

132

231

100

175 - 350

350 - 4900

160
200

279
349

100
100

175 - 350
175 - 350

350 - 4900
350 - 4900

M
3~

12

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Motor-starter combinations
Modules

1.4
1

Notes
Circuit-breaker

Contactor

Contactor

Type “1” coordination

Type “2” coordination

Type

Type

Type

NZMN1-M40
NZMN1-M50
NZMN1-M63

DILM40(…)
DILM50(…)
DILM65(…)

DILM80(…)
DILM80(…)
DILM80(…)

NZMN1-M80

DILM80(…)

DILM80(…)

NZMN1-M100

DILM95(…)

DILM95(…)

NZMN1-M100
NZMN2-M160

DILM115(…)
DILM150(…)

DILM115(…)
DILM150(…)

NZMN2-M200

DILM185A/22(…)

DILM185A/22(…)

NZMN2-M200
NZMN3-ME350

DILM225A/22(…)
DILM250/22(…)

DILM225A/22(…)
DILM250/22(…)

NZMN3-ME350

DILM300A/22(…)

DILM300A/22(…)

NZMN3-ME350

DILM400/22(…)

DILM400/22(…)

NZMN3-ME450
NZMN4-ME550

DILM500/22(…)
DILM580/22(…)

DILM500/22(…)
–

NZMN4-ME875
NZMN4-ME875

DILM650/22(…)
DILM750/22(…)

–
–

NZMN4-ME875
NZMN4-ME1400

DILM820/22(…)
DILM1000/22(…)

–
–

NZMH2-M50

DILM80(…)

DILM80(…)

NZMH2-M63

DILM80(…)

DILM80(…)

NZMH2-M80

DILM80(…)

DILM80(…)

NZMH2-M100

DILM95(…)

DILM95(…)

NZMH2-M125

DILM115(…)

DILM115(…)

NZMH2-M160

DILM150(…)

DILM150(…)

NZMH2-ME90
NZMH2-ME90

DILM80(…)
DILM80(…)

DILM80(…)
DILM80(…)

NZMH2-ME90

DILM95(…)

DILM95(…)

NZMH2-ME140
NZMH2-ME140

DILM115(…)
DILM150(…)

DILM115(…)
DILM150(…)

NZMH2-ME220

DILM185A/22(…)

DILM185A/22(…)

NZMH2-ME220

DILM225A/22(…)

DILM225A/22(…)

NZMH3-ME350

DILM250/22(…)

DILM250/22(…)

NZMH3-ME350
NZMH3-ME350

DILM300A/22(…)
DILM400/22(…)

DILM300A/22(…)
DILM400/22(…)

The motor-starter combinations consist of the motor protective circuit breaker
or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or
VDE 0660 Part 102.
I q = conditional rated current

The motor-starter combinations consist of the motor protective circuit breaker
or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or
VDE 0660 Part 102.
I q = conditional rated current

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

13

1.4

Motor-starter combinations
Modules

1 Modules NZMH and DILM

NZMH, DILM
Motor data

M
3~

14

Setting range

Rated operational
power
AC-3

Rated operational current

Rated short-circuit current

Overload trip

Short-circuit
release

500 V
525 V
P

500 V

525 V

500/525 V

Ie

Ie

kW

A

A

Iq

Ir

I rm

kA

A

A

11

17.4

17

15
18.5

23.4
28.9

22.5
28

50

16 - 20

350 - 350

50
50

20 - 25
25 - 32

350 - 350
320 - 448

22
30

33
44

32
43

50
50

32 - 40
40 - 50

320 - 560
400 - 700

37
45

54
65

54
64

50
50

50 - 63
63 - 80

504 - 882
640 - 1120

55

79

78

50

63 - 80

640 - 1120

75

107

106

50

100 - 125

1000 - 1750

90

129

127

50

125 - 160

1280 - 2240

30

44

43

50

45 - 90

90 - 1260

37
45
55

54
65
79

54
64
78

50
50
50

45 - 90
45 - 90
45 - 90

90 - 1260
90 - 1260
90 - 1260

75
90

107
129

106
127

50
50

70 - 140
70 - 140

140 - 1960
140 - 1960

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

I

Motor-starter combinations
Modules

1.4
1

Circuit-breaker

Type

Contactor

Contactor

Type “1” coordination

Type “2” coordination

Type

Type

NZMH2-M20

DILM40(…)

DILM80(…)

NZMH2-M25
NZMH2-M32

DILM40(…)
DILM40(…)

DILM80(…)
DILM80(…)

NZMH2-M40
NZMH2-M50

DILM40(…)
DILM80(…)

DILM80(…)
DILM80(…)

NZMH2-M63
NZMH2-M80

DILM80(…)
DILM80(…)

DILM80(…)
DILM80(…)

NZMH2-M80

DILM80(…)

DILM80(…)

NZMH2-M125

DILM115(…)

DILM115(…)

NZMH2-M160

DILM150(…)

DILM150(…)

NZMH2-ME90

DILM80(…)

DILM80(…)

NZMH2-ME90
NZMH2-ME90
NZMH2-ME90

DILM80(…)
DILM80(…)
DILM80(…)

DILM80(…)
DILM80(…)
DILM80(…)

NZMH2-ME140
NZMH2-ME140

DILM115(…)
DILM150(…)

DILM115(…)
DILM150(…)

Notes

The motor-starter combinations consist of the motor protective circuit breaker or
a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or
VDE 0660 Part 102.
I q = conditional rated current

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

15

1.4

Motor-starter combinations
Modules

PKZM0, DILM, ZB; NZMN1, DILM, ZB

1

Motor data

Modules PKM0, DILM and ZB with
and without automatic reset

Setting range

Rated operational
power
AC-3

Rated operational
current
AC-3

Rated short-circuit
current

380 V
400 V
415 V
P

400 V

380 - 415 V

Ie

kW

A

0.06
0.09

0.21
0.31

0.12
0.18
0.25

Basic unit

Overload trip

Short-circuit release

Iq

Ir

I rm

kA

A

A

100
100

0.16 - 0.24
0.24 - 0.4

3.5
5.6

0.41

100

0.4 - 0.6

8.82

PKM0-0,63

0.6
0.8

100
100

0.4 - 0.6
0.6 - 1

8.82
14

PKM0-0,63
PKM0-1

0.37

1.1

100

1 - 1.6

22.4

PKM0-1,6

0.55
0.75

1.5
1.9

100
100

1 - 1.6
1.6 - 2.4

22.4
35

PKM0-1,6
PKM0-2,5

1.1

2.6

100

2.4 - 4

56

PKM0-4

1.5
2.2

3.6
5

100
100

2.4 - 4
4-6

56
88.2

PKM0-4
PKM0-6,3

3

6.6

100

6 - 10

140

PKM0-10

4

8.5

100

6 - 10

140

PKM0-10

5.5

11.3

50

8 - 12

168

PKM0-12

5.5
7.5

11.3
15.2

50
50

10 - 16
10 - 16

168
224

PKM0-12
PKM0-16

11
15

21.7
29.3

50
50

16 - 24
20 - 32

350
448

PKM0-25
PKM0-32

18.5
18.5

36
36

50
50

24 - 40
3 - 65

320 - 560
320 - 560

NZMN1-S40
NZMN1-S40

22

41

50

40 - 57

400 - 700

NZMN1-S50

22

41

50

3 - 65

400 - 700

NZMN1-S50

30

55

50

40 - 57

504 - 882

NZMN1-S63

30
37

55
68

50
50

3 - 65
50 - 70

504 - 882
640 - 1120

NZMN1-S63
NZMN1-S80

37

68

50

10 - 145

640 - 1120

NZMN1-S80

45
45

81
81

50
50

70 - 100
10 - 145

800 - 1250
800 - 1250

NZMN1-S100
NZMN1-S100

55
55

99
99

50
50

70 - 100
10 - 145

800 - 1250
800 - 1250

NZMN1-S100
NZMN1-S100

I

Type

PKM0-0,25
PKM0-0,4

I>

M
3~

Modules NZMN1, DILM and Z...

I>

M
3~

16

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Motor-starter combinations
Modules

1.4
1

Contactor

Overload relay

Contactor

Overload relay

Current sensor

Type “1” coordination

Type “1” coordination

Type “2” coordination

Type “2” coordination

Type

Type

Type

Type

Type

DILM7-…(…)
DILM7-…(…)

ZB12-0,24
ZB12-0,4

DILM7-…(…)
DILM7-…(…)

ZB12-0,24
ZB12-0,4

–
–

DILM7-…(…)

ZB12-0,6

DILM7-…(…)

ZB12-0,6

–

DILM7-…(…)
DILM7-…(…)

ZB12-0,6
ZB12-1

DILM7-…(…)
DILM7-…(…)

ZB12-0,6
ZB12-1

–
–

DILM7-…(…)

ZB12-1,6

DILM7-…(…)

ZB12-1,6

–

DILM7-…(…)
DILM7-…(…)

ZB12-1,6
ZB12-2,4

DILM7-…(…)
DILM7-…(…)

ZB12-1,6
ZB12-2,4

–
–

DILM7-…(…)

ZB12-4

DILM7-…(…)

ZB12-4

–

DILM7-…(…)
DILM7-…(…)

ZB12-4
ZB12-6

DILM7-…(…)
DILM17-…(…)

ZB12-4
ZB32-6

–
–

DILM9-…(…)

ZB12-10

DILM17-…(…)

ZB32-10

–

DILM9-…(…)

ZB12-10

DILM17-…(…)

ZB32-10

–

DILM12-…(…)

ZB12-12

–

–

–

–
DILM17-…(…)

–
ZB32-16

DILM17-…(…)
DILM17-…(…)

ZB32-16
ZB32-16

–
–

DILM25-…(…)
DILM32-…(…)

ZB32-24
ZB32-32

DILM25-…(…)
DILM32-…(…)

ZB32-24
ZB32-32

–
–

DILM40(…)
–

ZB65-40
–

–
DILM40(…)

DILM50(…)

ZB65-57

–

–

–

DILM50(…)

DILM65(…)

ZB65-57

–

–
DILM80(…)

–
ZB150-70

DILM65(…)
–

–

–

DILM80(…)

DILM95(…)
–

ZB150-100
–

–
DILM95(…)

DILM115(…)
–

ZB150-100
–

–
DILM115(…)

Notes

The motor-starter combinations consist of the motor
protective circuit breaker (without overload function),
a contactor and overload relay modules.
They conform with IEC/EN 60947-4-1 or VDE 0660
Part 102.
I q = conditional rated current
The combinations can be operated with or without
manual reset. In the Manual position, the combination is
blocked against automatic restarting and must be reset
locally. In the Auto position, the combination automatically switches on again after the bimetallic elements
have cooled down.
Further information
Technical data PKZMO
Accessories PKZ
Technical data DILM
Further actuating voltages
DIL accessories
Technical data ZB...
Accessories ZB...

Page
Chapter 1.3
Chapter 1.3 (Page 10)
Chapter 1.1
Chapter 1.1 (Page 69)
Chapter 1.1 (Page 52)
Chapter 1.2
Chapter 1.2 (Page 21)

The motor-starter combinations consist of the circuitbreaker (without overload function), contactor and
overload relay module.
They conform with IEC/EN 60947-4-1 or VDE 0660
Part 102.
I q = conditional rated current
The combinations can be operated with or without
manual reset. In the Manual position, the combination is
blocked against automatic restarting and must be reset
locally. In the Auto position, the combination automatically switches on again after the bimetallic elements
have cooled down.
Maximum tripping tolerance CLASS10.
Further information
Technical data NZMN1
Accessories NZM1
Technical data DILM
Further actuating voltages
DIL accessories
Technical data ZB...
Accessories ZB...

Page
See catalog
See catalog
Chapter 1.1
Chapter 1.1 (Page 71)
Chapter 1.1 (Page 50)
Chapter 1.2
Chapter 1.2 (Page 21)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

17

1.4

Motor-starter combinations
Complete units

MSC-R: PKZM0, DILM

1

Motor data

Complete units MSC-R

Setting range

Rated
operational
power
AC-3

Rated
operational
current
AC-3

380 V
400 V
415 V
P

400 V

kW

Rated short-circuit
current

Overload
trip

Shortcircuit
releases

Motor starters
actuating voltage
230 V 50 Hz
Part no.
Article no.

380 - 415 V

380 - 415 V

Ie

Type “1”
coordination
Iq

Type “2”
coordination
Iq

Ir

I rm

A

kA

kA

A

A

0.06

0.21

150

50

0.16 - 0.25

3.5

0.09

0.31

150

50

0.25 - 0.4

5.6

0.12
0.18
0.25

0.41
0.6
0.8

150

50

0.4 - 0.63

8.82

150

50

0.63 - 1

14

0.37
0.55

1.1
1.5

150

50

1 - 1.6

22.4

MSC-R-1.6-M7(230V50Hz)
283176

0.75

1.9

150

50

1.6 - 2.5

35

MSC-R-2.5-M7(230V50Hz)
283178

1.1
1.5

2.6
3.6

150

50

2.5 - 4

56

MSC-R-4-M7(230V50Hz)
283179

2.2

5

150

50

4 - 6.3

88.2

MSC-R-6.3-M7(230V50Hz)
283181

3

6.6

150

–

6.3 - 10

140

MSC-R-10-M7(230V50Hz)
283182

4

8.5

150

–

6.3 - 10

140

MSC-R-10-M9(230V50Hz)
283183

5.5

11.3

50

–

8 - 12

168

MSC-R-12-M12(230V50Hz)
283184

3

6.6

50

50

6.3 - 10

140

MSC-R-10-M17(230V50Hz)
101049

4

11.3

50

50

8 - 12

168

7.5

15.2

50

50

10 - 16

224

MSC-R-12-M17(230V50Hz)
101050
MSC-R-16-M17(230V50Hz)
283186

11

21.7

50

50

20 - 25

350

15

29.3

50

50

25 - 32

448

I
MSC-R-0.25-M7(230V50Hz)
283171
MSC-R-0.4-M7(230V50Hz)
283172
MSC-R-0.63-M7(230V50Hz)
283173
MSC-R-1-M7(230V50Hz)
283175

M
3~

Complete units MSC-R

M
3~

18

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

MSC-R-25-M25(230V50Hz)
283187
MSC-R-32-M32(230V50Hz)
283188

Price
See price
list

Motor-starter combinations
Complete units

1.4
1

Motor starters
actuating voltage
24 V DC
Part no.
Article no.

Price
See price
list

Std. pack

Motor protective
circuit breaker

Contactor

Reversing starter
wiring set

Notes

Mechanical
connection
module,
electrical
contact module
and reversing
connector

Type

Type

Type

MSC-R-0.25-M7(24VDC)
283190
MSC-R-0.4-M7(24VDC)
283191

1 off

PKZM0-0,25

DILM7-01(...)

PKZM0-XRM12

1 off

PKZM0-0,4

DILM7-01(...)

PKZM0-XRM12

MSC-R-0.63-M7(24VDC)
283192

1 off

PKZM0-0,63

DILM7-01(...)

PKZM0-XRM12

MSC-R-1-M7(24VDC)
283194

1 off

PKZM0-1

DILM7-01(...)

PKZM0-XRM12

MSC-R-1.6-M7(24VDC)
283195

1 off

PKZM0-1,6

DILM7-01(...)

PKZM0-XRM12

MSC-R-2.5-M7(24VDC)
283197
MSC-R-4-M7(24VDC)
283198

1 off

PKZM0-2,5

DILM7-01(...)

PKZM0-XRM12

1 off

PKZM0-4

DILM7-01(...)

PKZM0-XRM12

MSC-R-6.3-M7(24VDC)
283200

1 off

PKZM0-6,3

DILM7-01(...)

PKZM0-XRM12

MSC-R-10-M7(24VDC)
283201
MSC-R-10-M9(24VDC)
283202

1 off

PKZM0-10

DILM7-01(...)

PKZM0-XRM12

1 off

PKZM0-10

DILM9-01(...)

PKZM0-XRM12

MSC-R-12-M12(24VDC)
283203

1 off

PKZM0-12

DILM12-01(...)

PKZM0-XRM12

MSC-R-10-M17(24VDC)
101051

1 off

PKZM0-10

DILM17-01(...)

PKZM0-XRM32

MSC-R-12-M17(24VDC)
101052

1 off

PKZM0-12

DILM17-01(...)

PKZM0-XRM32

MSC-R-16-M17(24VDC)
283204

1 off

PKZM0-16

DILM17-01(...)

PKZM0-XRM32

MSC-R-25-M25(24VDC)
283205

1 off

PKZM0-25

DILM25-01(...)

PKZM0-XRM32

MSC-R-32-M32(24VDC)
283206

1 off

PKZM0-32

DILM32-01(...)

PKZM0-XRM32

The reversing starters (complete devices) consist of a
PKZM0 motor protective circuit breaker and two
contactors DILM.
With the adapterless top-hat rail mounting of starters up
to 12 A, only the motor-protective circuit-breaker on the
top-hat rail requires an adapter. The contactors are
provided with mechanical support via a mechanical
connection element.
Control wire guide with max. 6 conductors with up to
2.5 mm external diameter or 4 conductors up to 3.5 mm
external diameter.
From 16 A, the motor protective circuit breaker and
contactors are mounted on the top-hat rail adapter plate.
The connection of the main circuit between PKZ and
contactor is established with electrical contact modules.
Complete units with mechanical interlock, starters up to
12 A also with electrical interlock.
When using auxiliary contacts DILA‐XHIT…
J Chapter 1.1 (Page 38) the electrical plugs can be
pulled without having to remove the front mounting
auxiliary contact.
Cannot be combined with standard auxiliary contact
NHI-E-...-PKZ0-C with spring-loaded terminal.
Further information
Technical data PKZM0
Accessories PKZ
Technical data DILM
Further actuation voltages
DILM accessories

Page
Chapter 1.3
Chapter 1.3 (Page 10)
Chapter 1.1
Chapter 1.1 (Page 69)
Chapter 1.1 (Page 50)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

19

1.4

Motor-starter combinations
Modules

PKZM, DILM

1

Motor data
Rated operational
power
400 V

Modules PKZM0 and DILM

Setting range
Rated operational
current
AC-3

Rated short-circuit current

Overload trip

Short-circuit
release

380 - 415 V

380 - 415 V

400 V

Type “2”
coordination
Iq

P

Ie

Type “1”
coordination
Iq

Ir

I rm

kW

A

kA

kA

A

A

0.06
0.09

0.21
0.31

150
150

50
50

0.16 - 0.25
0.25 - 0.4

3.5
5.6

0.12
0.18

0.41
0.6

150
150

50
50

0.4 - 0.63
0.4 - 0.63

8.82
8.82

0.25

0.8

150

50

0.63 - 1

14

0.37

1.1

150

50

1 - 1.6

22.4

0.55
0.75

1.5
1.9

150
150

50
50

1 - 1.6
1.6 - 2.5

22.4
35

1.1

2.6

150

50

2.5 - 4

56

1.5

3.6

150

50

2.5 - 4

56

2.2
3

5
6.6

150
150

50
50

4 - 6.3
6.3 - 10

88.2
140

4
5.5

8.5
11.3

150
50

50
50

6.3 - 10
8 - 12

140
168

7.5

15.2

50

50

10 - 16

224

11
15

21.7
29.3

50
50

50
50

20 - 25
25 - 32

350
448

5.5

11.3

50

50

10 - 16

224

7.5

15.2

50

50

10 - 16

224

11
15

21.7
29.3

50
50

50
50

20 - 25
25 - 32

350
448

M
3~
Modules PKZM4 and DILM

18.5

36

50

50

32 - 40

560

22

41

50

50

40 - 50

700

30

55

50

50

50 - 58

812

34

63

50

50

55 - 65

882

M
3~

20

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

I

Motor-starter combinations
Modules

1.4
1

Motor protective
circuit breaker

Type

Contactor

Contactor

Type “1”
coordination

Type “2”
coordination

Type

Type

Notes

PKZM0-0,25
PKZM0-0,4

2x
2x

DILM7-…(…)
DILM7-…(…)

2x
2x

DILM7-…(…)
DILM7-…(…)

PKZM0-0,63
PKZM0-0,63

2x

DILM7-…(…)
DILM7-…(…)

2x

2x

2x

DILM7-…(…)
DILM7-…(…)

PKZM0-1

2x

DILM7-…(…)

2x

DILM7-…(…)

PKZM0-1,6

2x

DILM7-…(…)

2x

DILM7-…(…)

PKZM0-1,6
PKZM0-2,5

2x

DILM7-…(…)
DILM7-…(…)

2x

2x

2x

DILM7-…(…)
DILM7-…(…)

PKZM0-4

2x

DILM7-…(…)

2x

DILM7-…(…)

PKZM0-4

2x

DILM7-…(…)

2x

DILM7-…(…)

PKZM0-6,3
PKZM0-10

2x

DILM7-…(…)
DILM9-…(…)

2x

DILM7-…(…)
DILM17-…(…)

PKZM0-10
PKZM0-12

2x

DILM9-…(…)
DILM12-…(…)

2x

2x

2x

DILM17-…(…)
DILM17-…(…)

PKZM0-16

2x

DILM17-…(…)

2x

DILM17-…(…)

PKZM0-25
PKZM0-32

2x

2x

2x

DILM25-…(…)
DILM32-…(…)

DILM25-…(…)
DILM32-…(…)

PKZM4-16

2x

DILM17-…(…)

2x

DILM17-…(…)

PKZM4-16

2x

DILM17-…(…)

2x

DILM17-…(…)

PKZM4-25
PKZM4-32

2x

DILM25-…(…)
DILM32-…(…)

2x

2x

2x

DILM25-…(…)
DILM32-…(…)

PKZM4-40

2x

DILM40(…)

2x

DILM40(…)

PKZM4-50

2x

DILM50(…)

2x

DILM50(…)

PKZM4-58

2x

DILM65(…)

2x

DILM65(…)

PKZM4-63

2x

DILM65(…)

2x

DILM65(…)

2x

2x

2x

The motor-starter combinations consist of the motor protective circuit breaker
or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or
VDE 0660 Part 102.
I q = conditional rated current
Further information
Technical data PKZM0
Accessories PKZ
Technical data DILM
Other operating voltages
DILM accessories

Page
Chapter 1.3
Chapter 1.3 (Page 10)
Chapter 1.1
Chapter 1.1 (Page 69)
Chapter 1.1 (Page 50)

The motor-starter combinations consist of the motor protective circuit breaker
or a circuit breaker and a contactor.
They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102.
I q = rated conditional short-circuit current.
Further information
Technical data PKZM0
Accessories PKZ
Technical data DILM
Other operating voltages
DILM accessories

Page
Chapter 1.3
Chapter 1.3 (Page 10)
Chapter 1.1
Chapter 1.1 (Page 70)
Chapter 1.1 (Page 50)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

21

1.4

Motor-starter combinations
Modules

NZMN, NZMH, DILM

1

Motor data

Modules NZMN and DILM

Setting range

Rated operational power

Rated operational current

AC-3

AC-3

380 V
400 V
415 V
P

400 V

Ie

kW

A

15
18.5

29.3
36

22
30

Rated short-circuit
current

Overload trip

Short-circuit
release

Iq

Ir

I rm

kA

A

A

50
50

25 - 32
32 - 40

320 - 448
320 - 560

41

50

40 - 50

400 - 700

55

50

50 - 63

504 - 882

37

68

50

63 - 80

640 - 1120

45

81

50

80 - 100

800 - 1250

55
75
90

99
134
161

50
50
50

80 - 100
125 - 160
160 - 200

800 - 1250
1280 - 2240
1600 - 2500

400/415 V

I

110

196

50

160 - 200

1600 - 2500

132

231

50

175 - 350

350 - 4900

160
200

279
349

50
50

175 - 350
175 - 350

350 - 4900
350 - 4900

250
315

437
544

50
50

225 - 450
275 - 550

450 - 6300
550 - 7700

400

683

50

438 - 875

875 - 12250

450

750

50

438 - 875

875 - 12250

500
560

820
947

50
50

438 - 875
700 - 1400

875 - 12250
1400 - 19600

22
30

41
55

100
100

40 - 50
50 - 63

400 - 700
504 - 882

M
3~
Modules NZMH and DILM

37

68

100

63 - 80

640 - 1120

55
55

81
100

100
100

80 - 100
100 - 125

800 - 1250
1000 - 1750

75

134

100

125 - 160

1280 - 2240

30
37

55
68

100
100

45 - 90
45 - 90

90 - 1260
90 - 1260

45

81

100

45 - 90

90 - 1260

55
75

100
134

100
100

70 - 140
70 - 140

140 - 1960
140 - 1960

90

161

100

110 - 120

220 - 3080

110

196

100

110 - 120

220 - 3080

132

231

100

175 - 350

350 - 4900

160
200

279
349

100
100

175 - 350
175 - 350

350 - 4900
350 - 4900

M
3~

22

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Motor-starter combinations
Modules

Circuit-breaker

Type

Contactor

Contactor

Type “1” coordination

Type “2” coordination

Type

Type

1.4
1

Notes

NZMN1-M32
NZMN1-M40

2x
2x

DILM40(…)
DILM40(…)

2x
2x

DILM80(…)
DILM80(…)

The motor starter combinations consist of the motor protective
circuit-breaker and a contactor.
They comply with IEC/EN 60947-4-1 and VDE 0660 Part 102.
I q = conditional rated current.

NZMN1-M50

2x

DILM50(…)

2x

DILM80(…)

NZMN1-M63

2x

DILM65(…)

2x

DILM80(…)

NZMN1-M80

2x

DILM80(…)

2x

DILM80(…)

NZMN1-M100

2x

DILM95(…)

2x

DILM95(…)

NZMN1-M100
NZMN2-M160
NZMN2-M200

2x
2x
2x

DILM115(…)
DILM150(…)
DILM185A/22(…)

2x
2x
2x

DILM115(…)
DILM150(…)
DILM185A/22(…)

NZMN2-M200

2x

DILM225A/22(…)

2x

DILM225A/22(…)

NZMN3-ME350

2x

DILM250/22(…)

2x

DILM250/22(…)

NZMN3-ME350
NZMN3-ME350

2x
2x

DILM300A/22(…)
DILM400/22(…)

2x
2x

DILM300A/22(…)
DILM400/22(…)

NZMN3-ME450
NZMN4-ME550

2x
2x

DILM500/22(…)
DILM580/22(…)

2x
2x

DILM500/22(…)
–

NZMN4-ME875

2x

DILM650/22(…)

2x

–

NZMN4-ME875

2x

DILM750/22(…)

2x

–

NZMN4-ME875
NZMN4-ME1400

2x
2x

DILM820/22(…)
DILM1000/22(…)

2x
2x

–
–

NZMH2-M50
NZMH2-M63

2x
2x

DILM80(…)
DILM80(…)

2x
2x

DILM80(…)
DILM80(…)

NZMH2-M80

2x

DILM80(…)

2x

DILM80(…)

NZMH2-M100
NZMH2-M125

2x
2x

DILM95(…)
DILM115(…)

2x
2x

DILM95(…)
DILM115(…)

NZMH2-M160

2x

DILM150(…)

2x

DILM150(…)

NZMH2-ME90
NZMH2-ME90

2x
2x

DILM80(…)
DILM80(…)

2x
2x

DILM80(…)
DILM80(…)

The motor-starter combinations consist of the motor protective
circuit breaker or a circuit breaker and a contactor.
They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102.
I q = rated conditional short-circuit current.

NZMH2-ME90

2x

DILM95(…)

2x

DILM95(…)

NZMH2-ME140
NZMH2-ME140

2x
2x

DILM115(…)
DILM150(…)

2x
2x

DILM115(…)
DILM150(…)

NZMH2-ME220

2x

DILM185A/22(…)

2x

DILM185A/22(…)

NZMH2-ME220

2x

DILM225A/22(…)

2x

DILM225A/22(…)

NZMH3-ME350

2x

DILM250/22(…)

2x

DILM250/22(…)

NZMH3-ME350
NZMH3-ME350

2x
2x

DILM300A/22(…)
DILM400/22(…)

2x
2x

DILM300A/22(…)
DILM400/22(…)

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

23

1.4

Motor-starter combinations
DOL starters

MSC-D.../BBA

1

Motor data

Motor
rating

AC-3

Complete devices PKZ
and DIL on BBA

Setting range

Rated
operational
current
AC-3

Rated short-circuit current

380 - 415 V

380 - 415 V

Type “1”
coordination

Type “2”
coordination

Overload
trip

Shortcircuit
release

380 V
400 V
415 V
P

400 V

Ie

Iq

Iq

Ir

I rm

kW

A

kA

kA

A

A

0.06

0.21

100

50

0.16 - 0.25

3.5

0.09

0.31

100

50

0.25 - 0.4

5.6

0.12
0.18

0.41
0.6

100

50

0.4 - 0.63

0.25

0.8

100

50

0.37
0.55

1.1
1.5

100

0.75

1.9

1.1
1.5
2.2

Std.
pack

I
1 off

8.82

MSC-D-0.63-M7(230V50Hz)/BBA 1)
102739

1 off

0.63 - 1

14

1 off

50

1 - 1.6

22.4

MSC-D-1-M7(230V50Hz)/BBA 1)
102950
MSC-D-1.6-M7(230V50Hz)/BBA 1)
102951

100

50

1.6 - 2.5

35

MSC-D-2.5-M7(230V50Hz)/BBA 1)
102952

1 off

2.6
3.6
5

100

50

2.5 - 4

56

1 off

100

50

4 - 6.3

88.2

MSC-D-4-M7(230V50Hz)/BBA 1)
102953
MSC-D-6.3-M7(230V50Hz)/BBA 1)
102954

3

6.6

100

–

6.3 - 10

140

MSC-D-10-M7(230V50Hz)/BBA
102955

1 off

4

8.5

100

–

6.3 - 10

140

1 off

5.5

11.3

100

–

8 - 12

168

MSC-D-10-M9(230V50Hz)/BBA
102956
MSC-D-12-M12(230V50Hz)/BBA
102957

7.5

15.2

50

–

10 - 16

224

MSC-D-16-M15(230V50Hz)/BBA
102958

1 off

3
4
5.5

6.6
8.5
11.3

100

50

6.3 - 10

140

1 off

100

50

8 - 12

168

MSC-D-10-M17(230V50Hz)/BBA
102959
MSC-D-12-M17(230V50Hz)/BBA
102960

7.5

15.2

50

50

10 - 16

224

MSC-D-16-M17(230V50Hz)/BBA 1)
102961

1 off

11

21.7

50

50

20 - 25

350

1 off

15

29.3

50

50

25 - 32

448

MSC-D-25-M25(230V50Hz)/BBA 1)
102962
MSC-D-32-M32(230V50Hz)/BBA 1)
102963

M
3~

I

M
3~

24

Price
See price
list

MSC-D-0.25-M7(230V50Hz)/BBA 1)
102737
MSC-D-0.4-M7(230V50Hz)/BBA 1)
102738

I

Complete devices PKZ
and DIL on BBA

Motor starters
actuating voltage
230 V 50 Hz
Part no.
Article no.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1 off

1 off

1 off

1 off

1 off

1 off

1.4

Motor-starter combinations
DOL starters

1
Motor starters
actuating voltage
24 V DC
Part no.
Article no.

Price
See price
list

Std.
pack

Motor
protective
circuit
breaker

Contactor

DOL starter
wiring set

Busbar
adapter

Type

Type

Type

Type

Notes

Mechanical connection module
and electrical
contact module

MSC-D-0.25-M7(24VDC)/BBA1)
102964
MSC-D-0.4-M7(24VDC)/BBA1)
102965

1 off

PKZM0-0,25

DILM7-10(…)

PKZM0-XDM12

BBA0-25

1 off

PKZM0-0,4

DILM7-10(…)

PKZM0-XDM12

BBA0-25

MSC-D-0.63-M7(24VDC)/BBA1)
102966

1 off

PKZM0-0,63

DILM7-10(…)

PKZM0-XDM12

BBA0-25

MSC-D-1-M7(24VDC)/BBA1)
102967
MSC-D-1.6-M7(24VDC)/BBA1)
102968

1 off

PKZM0-1

DILM7-10(…)

PKZM0-XDM12

BBA0-25

1 off

PKZM0-1,6

DILM7-10(…)

PKZM0-XDM12

BBA0-25

MSC-D-2.5-M7(24VDC)/BBA1)
102969

1 off

PKZM0-2,5

DILM7-10(…)

PKZM0-XDM12

BBA0-25

MSC-D-4-M7(24VDC)/BBA1)
102970
MSC-D-6.3-M7(24VDC)/BBA
102971

1 off

PKZM0-4

DILM7-10(…)

PKZM0-XDM12

BBA0-25

1 off

PKZM0-6,3

DILM7-10(…)

PKZM0-XDM12

BBA0-25

MSC-D-10-M7(24VDC)/BBA
102972

1 off

PKZM0-10

DILM7-10(…)

PKZM0-XDM12

BBA0-25

MSC-D-10-M9(24VDC)/BBA
102973

1 off

PKZM0-10

DILM9-10(…)

PKZM0-XDM12

BBA0-25

MSC-D-12-M12(24VDC)/BBA
102974
MSC-D-16-M15(24VDC)/BBA
102975

1 off

PKZM0-12

DILM12-10(…)

PKZM0-XDM12

BBA0-25

1 off

PKZM0-16

DILM15-10(…)

PKZM0-XDM12

BBA0-25

MSC-D-10-M17(24VDC)/BBA
102976
MSC-D-12-M17(24VDC)/BBA
102977

1 off

PKZM0-10

DILM17-10(…)

PKZM0-XM32DE

BBA0-32

1 off

PKZM0-12

DILM17-10(…)

PKZM0-XM32DE

BBA0-32

MSC-D-16-M17(24VDC)/BBA
102978

1 off

PKZM0-16

DILM17-10(…)

PKZM0-XM32DE

BBA0-32

MSC-D-25-M25(24VDC)/BBA
102979
MSC-D-32-M32(24VDC)/BBA
102980

1 off

PKZM0-25

DILM25-10(…)

PKZM0-XM32DE

BBA0-32

1 off

PKZM0-32

DILM32-10(…)

PKZM0-XM32DE

BBA0-32

The DOL starters (complete devices) consist of a
motor protective circuit breaker PKZM0 and a
contactor DILM. These combinations are
mounted on busbars.
The connection of the main circuit between PKZ
and contactor is established with electrical
contact modules.
Cannot be combined with standard auxiliary
contact NHI-E-...-PKZ0-C with spring-loaded
terminal.
Further information
Technical data PKZM0
Accessories PKZ
Technical data DILM
DILM accessories

Page
Chapter 1.3
Chapter 1.3 (Page 10)
Chapter 1.1
Chapter 1.1 (Page 50)

1) To

assemble Type F starters that conform
with UL508, incoming terminals BK25/3-PKZ0-E
and, if necessary, three-phase terminal blocks
B3.../...-PKZ0 can be added to motor starter
combinations.
Type F starter
Page 28

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

25

1.4

Motor-starter combinations
Reversing starters

MSC-R.../BBA

1

Motor starters
actuating voltage
230 V 50 Hz
Motor data
Motor rating

Rated short-circuit
current
380 - 415 V

380 - 415 V

380 V
400 V
415 V
P

400 V

Ie

Type “1”
coordination
Iq

Type “2”
coordination
Iq

Ir

I rm

kW

A

kA

kA

A

A

0.06

0.21

100

50

0.16 - 0.25

3.5

0.09

0.31

100

50

0.25 - 0.4

5.6

0.12
0.18
0.25

0.41
0.6
0.8

100

50

0.4 - 0.63

8.82

100

50

0.63 - 1

14

0.37
0.55

1.1
1.5

100

50

1 - 1.6

22.4

MSC-R-1.6-M7(230V50Hz)/BBA
102985

0.75

1.9

100

50

1.6 - 2.5

35

1.1
1.5

2.6
3.6

100

50

2.5 - 4

56

MSC-R-2.5-M7(230V50Hz)/BBA
102986
MSC-R-4-M7(230V50Hz)/BBA
102987

2.2

5

100

50

4 - 6.3

88.2

MSC-R-6.3-M7(230V50Hz)/BBA
102988

3

6.6

100

–

6.3 - 10

140

MSC-R-10-M7(230V50Hz)/BBA
102989

4

8.5

100

–

6.3 - 10

140

MSC-R-10-M9(230V50Hz)/BBA
102990

5.5

11.3

100

–

8 - 12

168

MSC-R-12-M12(230V50Hz)/BBA
102991

3
4

6.6
8.5

100

50

6.3 - 10

140

MSC-R-10-M17(230V50Hz)/BBA
102992

5.5

11.3

100

50

8 - 12

168

7.5

15.2

50

50

10 - 16

224

MSC-R-12-M17(230V50Hz)/BBA
102993
MSC-R-16-M17(230V50Hz)/BBA
102994

11

21.7

50

50

20 - 25

350

15

29.3

50

50

25 - 32

448

AC-3

Complete devices PKZ and DILM
on BBA for reversing starters

Setting range
Rated
operational
current
AC-3

Overload
trip

Short-circuit
release

Part no.
Article no.

I
MSC-R-0.25-M7(230V50Hz)/BBA
102981
MSC-R-0.4-M7(230V50Hz)/BBA
102982
MSC-R-0.63-M7(230V50Hz)/BBA
102983
MSC-R-1-M7(230V50Hz)/BBA
102984

M
3~

Complete devices PKZ and DILM
on BBA for reversing starters

M
3~

26

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

MSC-R-25-M25(230V50Hz)/BBA
102995
MSC-R-32-M32(230V50Hz)/BBA
102996

Price
See price
list

Motor-starter combinations
Reversing starters

1.4
1

Motor starters
actuating voltage
24 V DC

Price
See price
list

Std.
pack

Motor
protective
circuit
breaker

Contactor

Wiring set
Reversing
starters

Busbar
adapter

Notes

Mechanical connection module,
electrical contact
module and
reversing connector

Part no.
Article no.

Type

Type

Type

Type

MSC-R-0.25-M7(24VDC)/BBA
102997
MSC-R-0.4-M7(24VDC)/BBA
102998

1 off

PKZM0-0,25

2x

DILM7-01(…)

PKZM0-XRM12

BBA0R-25

1 off

PKZM0-0,4

2x

DILM7-01(…)

PKZM0-XRM12

BBA0R-25

MSC-R-0.63-M7(24VDC)/BBA
102999

1 off

PKZM0-0,63

2x

DILM7-01(…)

PKZM0-XRM12

BBA0R-25

MSC-R-1-M7(24VDC)/BBA
103000

1 off

PKZM0-1

2x

DILM7-01(…)

PKZM0-XRM12

BBA0R-25

MSC-R-1.6-M7(24VDC)/BBA
103001
MSC-R-2.5-M7(24VDC)/BBA
103002

1 off

PKZM0-1,6

2x

DILM7-01(…)

PKZM0-XRM12

BBA0R-25

1 off

PKZM0-2,5

2x

DILM7-01(…)

PKZM0-XRM12

BBA0R-25

MSC-R-4-M7(24VDC)/BBA
103003

1 off

PKZM0-4

2x

DILM7-01(…)

PKZM0-XRM12

BBA0R-25

MSC-R-6.3-M7(24VDC)/BBA
103004
MSC-R-10-M7(24VDC)/BBA
103005

1 off

PKZM0-6,3

2x

DILM7-01(…)

PKZM0-XRM12

BBA0R-25

1 off

PKZM0-10

2x

DILM7-01(…)

PKZM0-XRM12

BBA0R-25

MSC-R-10-M9(24VDC)/BBA
103006

1 off

PKZM0-10

2x

DILM9-01(…)

PKZM0-XRM12

BBA0R-25

MSC-R-12-M12(24VDC)/BBA
103007

1 off

PKZM0-12

2x

DILM12-01(…)

PKZM0-XRM12

BBA0R-25

MSC-R-10-M17(24VDC)/BBA
103008

1 off

PKZM0-10

2x

DILM17-01(…)

PKZM0-XM32DE +
DILM32-XRL

BBA0R-32

MSC-R-12-M17(24VDC)/BBA
103009
MSC-R-16-M17(24VDC)/BBA
103010

1 off

PKZM0-12

2x

DILM17-01(…)

BBA0R-32

1 off

PKZM0-16

2x

DILM17-01(…)

PKZM0-XM32DE +
DILM32-XRL
PKZM0-XM32DE +
DILM32-XRL

MSC-R-25-M25(24VDC)/BBA
103011

1 off

PKZM0-25

2x

DILM25-01(…)

PKZM0-XM32DE +
DILM32-XRL

BBA0R-32

MSC-R-32-M32(24VDC)/BBA
103012

1 off

PKZM0-32

2x

DILM32-01(…)

PKZM0-XM32DE +
DILM32-XRL

BBA0R-32

The reversing starters (complete
devices) consist of a PKZM0 motor
protective circuit breaker and two
contactors DILM.
These combinations are mounted on busbars.
The connection of the main circuit
between PKZ and contactor is established with electrical contact modules.
Complete units with mechanical interlock, starters up to 12 A also with
electrical interlock.
Further information
Technical data PKZM0
Accessories PKZ
Technical data DILM
DILM accessories

Page
Chapter1.3
Chapter 1.3 (Page 10)
Chapter1.1
Chapter 1.1 (Page 50)

BBA0R-32

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

27

1.4

Motor-starter combinations
Type F starter combinations

1 PKZMO, DILM, BK...
Maximum motor rating

Setting range

Alternating current HP

Overload trip

200 V
208 V

230 V
240 V

460 V
480 V

575 V
600 V

HP

HP

HP

HP

Short-circuit
release

Ir

I rm

A

A

0.1 - 0.16
0.1 - 0.16

2.2
2.2

I

Rated short-circuit
breaking capacity I cn
240 V 480 Y
600 Y
277 V 2)
347 V 2)

kA

kA

kA

65
65

65
65

50
50

Extension terminal

Motor protective
circuit breaker

Contactor

Type

Type

Type

BK25/3-PKZ0
BK25/3-PKZ0

PKZM0-0,16
PKZM0-0,16

DILEM…(…)
DILM7-…(…)

Modules PKZM0, DIL, BK
1)

½

½

0.16 - 0.25

3.4

65

65

50

BK25/3-PKZ0

PKZM0-0,25

DILEM…(…)

0.16 - 0.25

3.4

65

65

50

BK25/3-PKZ0

PKZM0-0,25

DILM7-…(…)

0.25 - 0.4
0.25 - 0.4

5.6
5.6

65
65

65
65

50
50

BK25/3-PKZ0
BK25/3-PKZ0

PKZM0-0,4
PKZM0-0,4

DILEM…(…)
DILM7-…(…)

0.4 - 0.63

8.8

65

65

50

BK25/3-PKZ0

PKZM0-0,63

DILEM…(…)

8.8
14

65
65

65
65

50
50

BK25/3-PKZ0
BK25/3-PKZ0

PKZM0-0,63
PKZM0-1

DILM7-…(…)
DILEM…(…)

½

½

0.4 - 0.63
0.63 - 1

½

½

0.63 - 1

14

65

65

50

BK25/3-PKZ0

PKZM0-1

DILM7-…(…)

¾

1

1 - 1.6

22

65

65

50

BK25/3-PKZ0

PKZM0-1,6

DILEM…(…)

¾
1

1
1½

1 - 1.6
1.6 - 2.5

22
35

65
65

65
65

50
50

BK25/3-PKZ0
BK25/3-PKZ0

PKZM0-1,6
PKZM0-2,5

DILM7-…(…)
DILEM…(…)

½

½

1

1½

1.6 - 2.5

35

65

65

50

BK25/3-PKZ0

PKZM0-2,5

DILM7-…(…)

1
1
1½

1
1
1½

2
2
3

3
3
5

2.5 - 4
2.5 - 4
4 - 6.3

56
56
88

65
65
65

65
65
65

50
50
50

BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0

PKZM0-4
PKZM0-4
PKZM0-6,3

DILEM…(…)
DILM7-…(…)
DILEM…(…)

1½
3

1½
3

3
7½

5
10

4 - 6.3
6.3 - 11

88
140

65
65

65
65

50
50

BK25/3-PKZ0
BK25/3-PKZ0

PKZM0-6,3
PKZM0-10

DILM7-…(…)
DILM9-…(…)

3

3

7½

–

9 - 12

168

65

65

50

BK25/3-PKZ0

PKZM0-12

DILM12-…(…)

3
3

5
5

10
10

–
–

10 - 16
10 - 16

224
224

50
18

50
18

–
–

BK50/3-PKZ4-E
BK50/3-PKZ4-E

PKZM0-16
PKZM0-16

DILM17-…(…)
DILM17-…(…)

5

5

10

–

16 - 20

280

18

18

–

BK50/3-PKZ4-E

PKZM0-20

DILM25-…(…)

5

7½

15

–

20 - 25

350

18

18

–

BK50/3-PKZ4-E

PKZM0-25

DILM25-…(…)

7½
10
20
–
Modules PKZM4, DIL, BK

25 - 32

448

18

18

–

BK50/3-PKZ4-E

PKZM0-32

DILM32-…(…)

3

5

10

15

10 - 16

224

65

65

50

BK50/3-PKZ4-E

PKZM4-16

DILM17-…(…)

5
7½

7½
10

15
25

20
30

16 - 27
24 - 34

350
448

65
65

65
65

50
50

BK50/3-PKZ4-E
BK50/3-PKZ4-E

PKZM4-25
PKZM4-32

DILM25-…(…)
DILM32-…(…)

10
10

15
15

30
30

30
–

32 - 40
40 - 52

560
700

65
65

65
65

50
–

BK50/3-PKZ4-E
BK50/3-PKZ4-E

PKZM4-40
PKZM4-50

DILM40(…)
DILM50(…)

15

15

40

–

50 - 56

812

65

65

–

BK50/3-PKZ4-E

PKZM4-58

DILM65(…)

15

15

40

–

52 - 58

882

65

65

–

BK50/3-PKZ4-E

PKZM4-63

DILM65(…)

Notes

28

Device for world markets IEC UL/CSA
Service factor (SF)
Set value Ir on the current scale, depending on the load factor
SF=1.15 -> Ir = 1 x I n mot
SF=1.0 -> Ir = 0.9 x I n mot
1) Calculate motor power in this range according to the rated operational current. Stated values to NEC
Table 430 - 150.
2) Suitable for networks with grounded star-point
Type F starter combinations do not need an upstream protective device.
For use in Canada, the switch must be fitted with an AK-PKZ0.

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.4

Motor-starter combinations
Function blocks

DILM, ZE, ZB, Z5, ZW7

1

Rating data for approved types1)

Max. rated motor
current

Contactor

Overload relay

Type

Type

Maximum motor rating
Alternating current HP
200 V
208 V
HP

230 V
240 V
HP

460 V
480 V
HP

575 V
600 V
HP

Maximum short-circuit protective device for North
America
Fuse
Circuit-breaker 2)
CEC or NEC
Continuous
Short-circuit
current
release

A

A

A

–

Modules DIL, Z
–
–

½

½

1

DILEM-…(…)

ZE-1.0

3

15

–

–

¾

1

1.4

DILEM-…(…)

ZE-1.6

6

15

–

½

½

1

1½

2.3

DILEM-…(…)

ZE-2.4

6

15

–

–

1

2

3

3.9

DILEM-…(…)

ZE-4

15

15

–

1½
–
2

1½
2
2

3
–
5

–
–
5

6
6.8
7.8

DILEM-…(…)
DILEM-…(…)
DILEM-…(…)

ZE-6
ZE-9
ZE-9

20
35
35

15
15
15

–
–
–

2
–

3
–

5
½

5
½

9.6
1

DILEM-…(…)
DILM7…(…)

ZE-12
ZB12-1

45
3

–
25

–
200

–

–

¾

1

1.4

DILM7…(…)

ZB12-1,6

6

25

200

½
1

½
1

1
2

1½
3

2.3
3.9

DILM7…(…)
DILM7…(…)

ZB12-2,4
ZB12-4

6
15

25
25

200
200

1½

½

3

–

6

DILM7…(…)

ZB12-6

20

25

200

–

–

–

7½

9

DILM9…(…)

ZB12-10

25

25

200

–
–

3
–

5
7½

7½
10

9.6
11

DILM12…(…)
DILM12…(…)

ZE-12
ZB12-12

25
45

25
25

200
200

–

5

10

–

15.2

DILM15…(…)

ZB12-16

60

40

320

–
–
½

–
–
½

½
¾
1

½
1
1½

1
1.4
2.3

DILM17…(…)
DILM17…(…)
DILM17…(…)

ZB32-1
278447
ZB32-2,4

3
6
6

25
25
25

200
200
200

1

1

2

3

3.9

DILM17…(…)

ZB32-4

15

25

200

½

1½

3

–

6

DILM17…(…)

ZB32-6

20

25

200

–

3

5

7½

9.6

DILM17…(…)

ZB32-10

25

25

200

–
–

–
5

7½
10

10
–

11
15.2

DILM17…(…)
DILM17…(…)

ZB32-16
ZB32-16

40
40

30
30

320
320

–
–

7½
10

15
20

20
25

22
32.2

DILM25…(…)
DILM32…(…)

ZB32-24
ZB32-32

90
125

100
125

1200
1200

–

3

5

7½

9.6

DILM40(…)

ZB65-10

40

40

380

–
–

5
7½

10
20

10
25

15.2
32.2

DILM40(…)
DILM40(…)

ZB65-16
ZB65-24

60
90

60
90

760
1200

–

10

20

30

34

DILM40(…)

ZB65-40

125

125

1200

–

20

40

50

54

DILM50(…)

ZB65-57

200

150

2000

–
–

20
25

50
50

50
60

63
68

DILM65(…)
DILM80(…)

ZB65-65
ZB150-70

200
250

160
250

2000
2500

–

30

75

100

99

DILM95(…)

ZB150-100

400

400

3200

–

40

100

100

124

DILM115(…)

ZB150-125

500

500

4000

–
50

60
60

125
125

125
150

156
156

DILM150(…)
DILM185A/22(…)

ZB150-150
Z5-160/FF225A

600
600 CLASS J

600
600

4800
7200

60

75

150

200

192

DILM225A/22(…)

Z5-220/FF225A

800 CLASS J

800

16000

75
100

100
125

200
250

250
300

248
312

DILM250/22(…)
DILM300A/22(…)

Z5-250/FF250
ZW7-400

700 CLASS J
1000

600
1000

–
–

125

150

300

400

382

DILM400/22(…)

ZW7-400

1000

1000

–

150

200

400

500

480

DILM500/22(…)

ZW7-540

1000

600

–

Notes

1)

Devices for world markets IEC UL/CSA
2) Circuit-breaker -> See catalog

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

29

1.4

Motor-starter combinations
Function blocks

1 NZMH...-S...-CNA, DILM..., ZB, Z5, ZW7
Rating data for approved
types
Maximum motor rating
Alternating current HP
200 V
208 V

230 V
240 V

460 V
480 V

575 V
600 V

HP

HP

HP

HP

Setting range
Max. rated
motor
current

A

Rated short-circuit
breaking capacity

Overload
trip

Circuit-breaker

Contactor

Overload
relay

Type

Type

Type

Shortcircuit
releases

480 V

600 Y
347 V 1)

600 V
Ir

I rm

kA

kA

kA

A

A

I

Minimum
enclosure
volume

cm 3

Module NZMH...-S...-CNA, DILM, Z

I>

M
3~

–
–

–
–

–
½

½
¾

0.9
1.3

100
100

50
50

–
–

0.6 - 1
1 - 1.6

12.8 - 22.5
12.8 - 22.5

NZMH2-S1.6-CNA
NZMH2-S1.6-CNA

DILM17-…(…)
DILM17-…(…)

ZB32-1
ZB32-1,6

81.5
81.5

–

–

¾

–

1.6

100

50

–

1 - 1.6

19.2 - 33.6

NZMH2-S2.4-CNA

DILM17-…(…)

ZB32-1,6

81.5

–
–

–
½

1
–

1
1½

2.1
2.4

100
100

50
50

–
–

1.6 - 2.4
1.6 - 2.4

19.2 - 33.6
32 - 56

NZMH2-S2.4-CNA
NZMH2-S5-CNA

DILM17-…(…)
DILM17-…(…)

ZB32-2,4
ZB32-2,4

81.5
81.5

¾
–
1

¾
1
1½

2
–
3

3
–
–

3.9
4.2
6

100
100
100

50
50
50

–
–
–

2.4 - 4
4-6
4-6

32 - 56
32 - 56
48 - 84

NZMH2-S5-CNA
NZMH2-S5-CNA
NZMH2-S8-CNA

DILM17-…(…)
DILM17-…(…)
DILM17-…(…)

ZB32-4
ZB32-6
ZB32-6

81.5
81.5
81.5

1½

2

–

5

6.9

100

50

–

6 - 10

48 - 84

NZMH2-S8-CNA

DILM17-…(…)

ZB32-10

81.5

2

3

5

7½

9.6

100

50

–

6 - 10

80 - 140

NZMH2-S12-CNA

DILM17-…(…)

ZB32-10

81.5

3

5

10

10

15.2

100

50

–

10 - 16

128 - 224

NZMH2-S18-CNA

DILM17-…(…)

ZB32-16

81.5

5

–

–

15

17.5

100

50

–

16 - 24

200 - 350

NZMH2-S26-CNA

DILM17-…(…)

ZB32-24

81.5

–

7½

15

20

22

100

50

–

16 - 24

200 - 350

NZMH2-S26-CNA

DILM25-…(…)

ZB32-24

81.5

7½
–

–
10

–
20

–
25

25.3
28

100
100

50
50

–
–

24 - 32
24 - 32

256 - 448
256 - 448

NZMH2-S33-CNA
NZMH2-S33-CNA

DILM25-…(…)
DILM32-…(…)

ZB32-32
ZB32-32

81.5
81.5

10
–

–
–

–
25

–
30

32.2
34

100
100

50
50

–
–

24 - 32
32 - 40

320 - 560
320 - 560

NZMH2-S40-CNA
NZMH2-S40-CNA

DILM32-…(…)
DILM40(…)

ZB32-32
ZB65-40

81.5
81.5

–

–

30

–

40

100

50

–

32 - 40

400 - 700

NZMH2-S50-CNA

DILM40(…)

ZB65-40

81.5

–

15

–

40

42

100

50

–

40 - 57

400 - 700

NZMH2-S50-CNA

DILM40(…)

ZB65-57

81.5

15

20

40

50

54

100

50

–

40 - 57

504 - 882

NZMH2-S63-CNA

DILM50(…)

ZB65-57

81.5

20
–

–
25

50
–

60
–

65
68

100
100

50
50

–
–

57 - 65
50 - 70

640 - 1120
640 - 1120

NZMH2-S80-CNA
NZMH2-S80-CNA

DILM65(…)
DILM80(…)

ZB65-65
ZB150-70

81.5
163

25

30

60

75

80

100

50

–

70 - 100

800 - 1400

NZMH2-S100-CNA

DILM80(…)

ZB150-100

163

–
30

40
–

75
–

100
–

104
92

100
100

50
50

–
–

70 - 100
70 - 100

1000 - 1750
1000 - 1750

NZMH2-S125-CNA
NZMH2-S125-CNA

DILM95(…)
DILM115(…)

ZB150-100
ZB150-100

163
163

40
–

–
50

100
–

125
–

125
130

100
100

50
50

–
–

100 - 125
125 - 150

1280 - 2240
1280 - 2240

NZMH2-S160-CNA
NZMH2-S160-CNA

DILM115(…)
DILM115(…)

ZB150-125
ZB150-150

163
163

–

–

125

–

156

100

50

–

125 - 150

1600 - 2500

NZMH2-S200-CNA

DILM150(…)

ZB150-150

265

50

60

–

150

154

100

50

–

120 - 160

1600 - 2500

NZMH2-S200-CNA

DILM185/22(…)

Z5-160/FF250

265

60
75

75
100

150
200

200
250

192
248

100
100

50
50

–
50

160 - 220
160 - 220

220 - 3080
350 - 4900

NZMH2-SE220-CNA
NZMH3-SE350-CNA

DILM225/22(…)
DILM250/22(…)

Z5-220/FF250
Z5-220/FF250

265
306

100
–

–
125

–
250

300
–

289
302

100
100

50
50

50
50

190 - 290
270 - 400

350 - 4900
450 - 6300

NZMH3-SE350-CNA
NZMH3-SE450-CNA

DILM300/22(…)
DILM300/22(…)

ZW7-290
ZW7-400

306
306

125

150

300

400

382

100

50

50

270 - 400

450 - 6300

NZMH3-SE450-CNA

DILM400/22(…)

ZW7-400

306

Notes

30

1)

Suitable for networks with grounded star-point

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Connection system SmartWire-DT®
Function blocks

1.4

Description

1

SWIRE-…

1
2
3
4
5

XI /ON

9
13

9
8

10

7

11
12

1
2
3
4
5
6
7
8
9
10
11
12

Gateway easy NET/CAN open
Gateway PROFIBUS-DP
Gateway MODBUS
Coupling unit XI/ON with SmartWire-DT®
Interface card MicroInnovation AG,
www.microinnovation.com
Interface module B & R CS1011
for X20 system,
www.br-automation.com
SmartWire-DT® I/O module
DOL starter MSC-D up to 32 A
DOL starter MSC-D up to 15.5 A
SmartWire-DT® power module
Connection cable
SmartWire-DT® module for DILM
Reversing starter MSC-R up to 12 A

System description

Features

With the SmartWire-DT® connection system,
switchgear can be connected to a programmable
logic controller without the need for complex
control wiring. Plug-in SmartWire-DT® cards for
DILM and a preassembled connection cable
replace the control wiring, dramatically reducing
wiring complexity and completely eliminating
wiring errors. SmartWire-DT® also cuts the time
needed for installation, commissioning and
troubleshooting.
The PLC’s inputs and outputs are replaced by the
SmartWire-DT® module for DILM, and no control
wiring terminals are required.
Connection to the various fieldbus systems is
through third-party gateways or interface
modules.

• Gateway
• Connects the SmartWire-DT® cards with
the fieldbus
• Supports the fieldbus standards
PROFIBUS-DP, MODBUS, CANopen and
easy-NET
• Supplies the control voltage for the motor
starter or contactor
• Supplies the supply voltage for the
SmartWire-DT® connection system
• Configuration button for automatic
addressing of the SmartWire-DT® modules
for DILM
• Supports max. 16 SmartWire-DT® modules
for DILM
• Interface of third-party manufacturers, e.g.
for the XI/ON I/O system, X20 system CS1011
interface module
• Connection to the field buses
PROFIBUS-DP, MODBUS, CANopen and
DeviceNET
• SmartWire-DT® module for DILM
• Pluggable on contactors
• Suitable for contactors DILM7 to DILM32
(24 V DC), DILMC7 to DILMC32 (24 V DC),
DILMP20 (24 V DC) or motor starter
MSC-... (24 V DC)
• Use the standard switchgear of the xStart
range
• Suitable for DOL and reversing starters
• The accessories of the contactor series
can be used

• Suitable for contactor combinations with
PKZ or with Z relays
• Integrated switch position monitoring of
the contactors
• Integrated mechanical switch position
display
• Actuation of the contactors
• Scanning of a potential-free contact, e.g.
NHI-E-10-PKZ0
• Electrical interlocking, e.g. possible with
reversing starters
• LED for status and diagnostic display
• Connection to gateway or interface from
third party devices
• SmartWire-DT® I/O module
• 4 digital inputs for connection of
potential-free contacts
• Power supply for the digital inputs comes
from the device
• 2 relay outputs 250 V AC
• SmartWire-DT® power module
• Supply of the 24 V DC control voltage for
actuation of contactors DILM
• Assembly of Emergency Off groups
• Increases the control voltage power in the
SmartWire-DT® line
• Safety engineering
• Emergency switching off disconnection as
per IEC/EN 954-1, Switching Category 3
• Central switch off of control voltage at the
gateway or SmartWire-DT® power module
• Combination with safety-relevant
switchgear possible

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

31

1.4
1

Connection system SmartWire-DT®

Ordering
SWIRE-…
Description

Part no.
Article no.

Gateway
Gateway with integrated supply for the SmartWire-DT®
module and control voltage for the switchgear.
- Connection to PROFIBUS-DP as slave.
- Transmission rate: 9.6 Kbits/s to 12 MBit/s.
- 9 pole SUB-D socket.
- Address range 1…126.
- Connection to SmartWire-DT® module as master.
- Supports 16 SmartWire-DT® modules.

PROFIBUS-DP

Gateway with integrated supply for the SmartWire-DT®
module and control voltage for the switchgear.
- Connection to MODBUS-RTU as slave.
- Transmission rate: 9.6 to 57.6 Kbits/s.
- 9 pole SUB-D socket RS232/RS485.
- Address range 1…31.
- Connection to SmartWire-DT® module as master.
- Supports 16 SmartWire-DT® modules.

MODBUS

Price
See price
list

Std. pack

Notes

SWIRE-GW-DP
107027

1 off

–

SWIRE-GW-MB
118562

1 off

–

Modules
SmartWire-DT® module
for DILM

SmartWire-DT® module to assemble on the contactors
DILM(C)7…DILM(C)38, DILA…, DILMP20
- One module is necessary per contactor.
- Connection to SmartWire-DT® gateway as slave.
- Max. 16 SmartWire-DT® modules per line.
- 1 digital input for floating contact.
- Signaling contactor switch position.

SWIRE-DIL
107028

5 off

• Take account of the max. current consumption of the contactor coils per
SmartWire-DT® line.
• Length of connection cable at the input and
the electrical interlock < 2.8 m.
• The A2 connection of the contactors must
not be linked.
• Electrical interlocking only possible via the
terminals on the module for DILM.
• Wiring sets DILM 12-XRL and PKZM0XRM12 cannot be used.
• Connection terminals for electrical
interlocking are not suitable for safety
technology.

SmartWire-DT®
power module

Power module for suppling the control voltage.
- Connection on SmartWire-DT® gateway as
interactive station (no address).

SWIRE-PF
107029

1 off

Max. 4 power modules per SmartWire-DT®
line.

SmartWire-DT® I/O
mod-ule

4 digital inputs
2 digital relay outputs

SWIRE-4DI-2DO-R
107030

1 off

Max. 4 SmartWire-DT® I/O modules per line.

Information relevant for export to North America

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

32

IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05;
CE marking
E29184
NKCR
012528
2252-01
UL Listed, CSA certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1.4

Connection system SmartWire-DT®

SWIRE-…

1
Description

Part no.
Article no.

Price
See price
list

Std. pack

Notes

Cable lengths: Engineering

Accessory
SmartWire-DT® connection cable 1)
Length: 85 mm

SWIRE-CAB-008
107032

25 off

Length: 110 mm

SWIRE-CAB-011
107033

25 off

Length: 150 mm

SWIRE-CAB-015
107034

5 off

Length: 250 mm

SWIRE-CAB-025
107035

5 off

Length: 500 mm

SWIRE-CAB-050
112027

1 off

Length: 1000 mm

SWIRE-CAB-100
107036

1 off

Length: 2000 mm

SWIRE-CAB-200
107037

1 off

SWIRE-CAB-000
107031

25 off

–

6-core, ribbon cable, length: 100 m.

SWIRE-CAB-100M
107038

1 off

Preassembly of cable only possible with
special tool.

6-pin plug for ribbon cable.

SWIRE-CAB-CON
107039

50 off

For use with SWIRE-CAB-100M.

NHI-E-10-PKZ0 with connection cable AWG18 blue,
for connection to SmartWire-DT® module for DILM.

NHI-E-10L-PKZ0
107040

5 off

–

DILM12-XR
110099

20 off

For use with DILM7…DILM15, without A2 link.

Termination connector 1)
–
Termination plug for last SmartWire-DT® card,
6 pole, no electrical function.
Data cable 1)
–

34

Plug 1)
–
NHI-E with cable 1)
–

Plug-in reversing bridge 2)
–

For assembling reversing starters with tool-less
plug connection

Information relevant for export to North America
1)
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05; CE marking
E29184
NKCR
012528
2252-01
UL Listed, CSA certified

2)
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No.14-05; CE marking
E36332
NLRV
012528
3211-05
UL Listed, CSA certified

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

33

1.4
1

Connection system SmartWire-DT®

Engineering
SWIRE-…
Cable lengths
For connection between motor starters and contactors DILM, the cable lengths depend on the combination and assembly of the devices.
Applications

PKZ accessories

from

to

Cable length

Contactors DILM

None
(45 grid)

DILM7-…15
DILM17-…38
DILM7-…38
DILM17-…38
DILM7-…15
DILM17-…32
DILM7-…15
DILM17-…32
DILM7-…15
DILM17-…32
DILM7-…15
DILM17-…32
DILM7-…15
DILM17-…32
DILM7-…15
DILM17-…32

DILM7-…15
DILM17-…38
DILM17-…38
DILM7-…15
DILM7-…15
DILM17-…32
DILM17-…32
DILM7-…15
DILM7-…15
DILM17-…32
DILM17-…32
DILM7-…15
DILM7-…15
DILM17-…32
DILM17-…32
DILM7-…15

85 mm
85 mm
110 mm
110 mm
110 mm
110 mm
110 mm
110 mm
85 mm
85 mm
110 mm
110 mm
110 mm
110 mm
150 mm
150 mm

PKZM0 with U-/A…/NHI…/AGM…

Motor starters MSC

None
(45 grid)

PKZM0 with U-/A…/NHI…/AGM…

SWIRE-…
Cable lengths
The cable lengths for connecting SmartWire-DT® devices depend on the combination and assembly of the devices.
Applications

Cable length

Connection from power module to SWIRE-DIL with mounting beside PKZ
Connection from power module to SWIRE-DIL with mounting beside DILM
Connection from gateway to SWIRE-DIL with mounting beside PKZ
Connection from coupling unit to SWIRE-DIL with mounting beside DILM

250 mm
150 mm
250 mm
250 mm

SWIRE-…
Magnet systems
The number of motor starters or contactors DILM that can be connected is dependant on the power consumption of the magnet systems per SmartWire-DT® line.
To increase the number of SmartWire-DT® modules that can be connected, power modules can be used.
24 V DC
Pick-up power
Holding power

34

W
W

DILM7

DILM9

DILM12

DILM15

DILM17

DILM25

DILM32/38

3
3

3
3

4.5
4.5

12 at 24 V
0.5 at 24 V

12 at 24 V
0.5 at 24 V

12 at 24 V
0.5 at 24 V

12 at 24 V
0.5 at 24 V

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Connection system SmartWire-DT®

1.4

Technical data

1

SWIRE-…
SWIRE-GW-DP
General
Standards
General

SWIRE-PF

SWIRE-DIL

Dimensions (w x d x h)
Weight
Terminal capacity

mm
kg

IEC/EN 60947
EN 55011
EN 55022
IEC/EN 61000-4
IEC/EN 60068-2-27
IEC 61158
–
Top-hat rail IEC/EN 60715 (35mm) or screw fixing with fixing
brackets ZB4-101-GF1 (accessories)
35 x 90 x 109
35 x 90 x 74
0.15
0.1

Solid
Flexible with ferrule
Solid or stranded
Flat-blade screwdriver
Max. tightening torque
Ambient climatic conditions
Ambient temperature
Operation
Storage
Condensation
Relative humidity, non-condensing (IEC/EN 60068-2-30)
Air pressure (in operation)
Ambient mechanical conditions
Protection type (IEC/EN 60529)
Pollution degree
Mounting position
Electromagnetic compatibility (EMC)
Electrostatic discharge (IEC EN 61000-4-2, Level 3, ESD)
Air discharge
Contact discharge
Electromagnetic fields
(IEC/EN 61000-4-3, RFI)
Radio interference suppression (EN 55011, EN 55022)
Burst pulses(IEC/EN 61000-4-4, level 3)
Supply cables
Signal cables
High-energy pulses (surge)
(IEC/EN 61000-4-5, level 2)

mm²
mm²
AWG
mm
Nm

0.34…1.5
0.34…1.5
22…16
3.5 x 0.8
0.6

°C
°C

-25 - +55
-25 - +55
-25 - +70
-25 - +70
Prevent condensation by means of suitable measures
5 - 95
5 - 95
795 - 1080
795 - 1080

-25 - +60
-25 - +70

IP20
2
Vertical

IP20
2
Vertical

IP20
2
As per DILM7 to DILM38

8
–
10

8
–
10

8
–
10

Class A

Class A

Class A

kV
kV
kV

2
2
0.5 (supply cables, symmetrical)

2
2

2
2

V

10

10

10

Profibus-DP
Mounting

Emitted RFI (IEC/EN 61000-4-6)
Insulation resistance

%
hPa

kV
kV
V/m

0.34…1.5
0.34…1.5
22…16
3.5 x 0.8
0.6

–
on DILM7…DILM38
45 x 44 x 81
0.04
0.34…1.5
0.34…1.5
22…16
3.5 x 0.8
0.5

5 - 95
795 - 1080

Clearances and creepage distances
EN 50178, EN 60947-1, UL 508, CSA C22.2 No 142
Insulation resistance
EN 50178, EN 60947-1
Supply voltage, gateway electronics and SmartWire-DT® station electronics
Ugateway
Rated operational voltage Ugateway
Permissible range

V DC

24, -15 %, +20 %
20.4...28.8

–
20.4...28.8

–
Supply from gateway or
power module

Ripple
Maximum coupling unit power consumption at
24 V DC

%
mA

–
–

–
–

Voltage dips (IEC/EN 61131-2)
Heat dissipation at 24 V DC
Protection against polarity reversal
Short-circuit protection, SmartWire-DT® side

ms
W

̰5
500
(typically 100 for gateway +
typically 25 per SmartWire-DT®
module)
10
Normally 6
Yes
Yes

–
Normally 1

–
Normally 0.6

–

–

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

35

1.4

Connection system SmartWire-DT®

SWIRE-…
1

SWIRE-GW-DP

SWIRE-PF

SWIRE-DIL

24, -15 %, +20 %
(Derating from > 40 °C)
20.4…28.8,
at 45 °C: 21…28.8,
at 50 °C: 21.6…28.8,
at 55 °C: 22.2…27.6
Normally 3

Supply from gateway or
power module
Supply from gateway or
power module

10

̰5
10

–
–

No, external fuse
3 A or FAZ-Z3

No, external fuse
3 A or FAZ-Z3

–

LED indicators
Operational

Ready: green

–

Ready: green

Power supply, SmartWire-DT® contactors

U Aux : green

U Aux : green

–

PROFIBUS-DP status
SmartWire-DT® status

PROFIBUS-DP: green
SmartWire-DT®: green

–
–

–
above Ready

Output status

–

–

–
1

General
Supply voltage UAUX (supply voltage for switching SmartWire-DT® elements,
e.g. contactor coils)
V DC
24, -15 %, +20 %
Rated operational voltage UAUX
(Derating from > 40 °C)
Permissible range
V DC
20.4…28.8,
at 45 °C: 21…28.8,
at 50 °C: 21.6…28.8,
at 55 °C: 22.2…27.6
Input current UAUX at 24 V DC
A
Normally 3
Ripple
%
̰5
Voltage dips (IEC/EN 61131-2)

ms

Protection against polarity reversal
Short-circuit protection, SmartWire-DT® side

–

Connection floating contacts
Number

–

–

V DC

–

–

17

Input current at “1” signal, typically

mA

–

–

5

Potential isolation
Max. cable length

m

–
–

–
–

No
< 2.8

Rated voltage (internal supply)

Ue

PROFIBUS-DP
Terminal type

SUB-D 9-pole, socket

–

–

Station address

1 … 125

–

–

Address setting

DIP switches

–

–

Potential isolation
From UAUX power supply

Yes

–

From UGateway power supply

Yes

To SmartWire-DT®

–

Bus protocol

Yes
PROFIBUS-DP
slave
PROFIBUS-DP

–

–

Bus Terminating Resistors

can be connected via plug

–

–

Baud rate

Automatic, up to 12 Mbits/s

–

–

Function

SmartWire-DT®
Terminal type

Plug, 6-pole

Plug, 6-pole

Plug, 6-pole

Data/power cable
Maximum cable length, SmartWire-DT® system

6-core ribbon cable
Max. 4

6-core ribbon cable
Max. 4

6-core ribbon cable
Max. 4

m

Bus termination

No

Plug connectors

Plug connectors

Station address
Station
Address setting

Automatic assignment
max. 126 PROFIBUS
stations
None

None
Max. 4 SmartWire-DT® cards
per line
None

1…16
Max. 16 SmartWire-DT® cards
per line
automatically via SmartWire-DT®

Potential isolation
From UAUX power supply

No

No

No

No

No

No

SmartWire-DT® master

no SmartWire-DT® station

SmartWire-DT® slave

–
–

–
–

Normally 20 ms for all stations
Normally 10 ms per station

From UGateway power supply
Function
Data transfer time, SmartWire-DT® system
Write switch
Read status information

36

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Connection system SmartWire-DT®

1.4

SWIRE-…
SWIRE-4DI-2DO-R

1

SWIRE-GW-MB

General
Standards
General

Dimensions (w x d x h)
Weight
Terminal capacity
Solid

mm
kg

IEC/EN 60947, EN 55011, EN 55022,
IEC/EN 61000-4, IEC/EN 60068-2-27
Tophat rail IEC/EN 60715 (35 mm) or screw fixing with fixing brackets
ZB4-101-GF1 (accessories)
35 x 90 x 74
35 x 90 x 109
0.12
0.15

mm²

0.5…1.5

0.5…1.5

Flexible with ferrule
Solid or stranded

mm²
AWG

0.5…1.5
22…16

0.5…1.5
22…16

Flat-blade screwdriver
Max. tightening torque
Ambient climatic conditions
Ambient temperature
Operation

mm
Nm

3.5 x 0.8
0.6

3.5 x 0.8
0.6

°C

-25 - +55

-25 - +55

°C

Mounting

Storage
Condensation
Relative humidity, non-condensing (IEC/EN 60068-2-30)

%

-25 - +70
-25 - +70
Prevent condensation by means of suitable measures
5 - 95
5 - 95

Air pressure (in operation)

hPa

795 - 1080

795 - 1080

IP20
2
Vertical

IP20
2
Vertical

kV

8

8

kV

–
10
Class A

–
10
Class A

kV
kV
kV

2
–
0.5 (supply cables, symmetrical)

2
2

V

10

10

Ambient mechanical conditions
Protection type (IEC/EN 60529, EN50178, VBG 4)
Pollution degree
Mounting position
Electromagnetic compatibility (EMC)
Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD)
Air discharge
Contact discharge
Electromagnetic fields (IEC/EN 61000-4-3, RFI)
Radio interference suppression (EN 55011, EN 55022)
Burst pulses (IEC/EN 61000-4-4, level 3)
Supply cables
Signal cables
power pulses (surge) (IEC/EN 61000-4-5, level 2)

V/m

Emitted RFI (IEC/EN 61000-4-6)
Insulation resistance
Clearances and creepage distances
Insulation resistance
Supply voltage, gateway electronics and SmartWire-DT® station
electronics Ugateway

EN 50178, EN 60947-1, UL 508, CSA C22.2 No 142
EN 50178, EN 60947-1

Rated operational voltage Ugateway
Permissible range

V DC

–
Supply from gateway or power module

24, -15 %, +20 %
20.4...28.8

Ripple
Maximum gateway current consumption at 24 V DC

%
mA

–
–

Voltage dips (IEC/EN 61131-2)
Heat dissipation at 24 V DC
Protection against polarity reversal
Short-circuit protection, SmartWire-DT® side
Power supply UAUX (power supply for switching the
SmartWire-DT® slaves, e.g. contactor coils)

ms
W

–
–

̰5
500 (normally 100 coupling unit +
normally 25 per SmartWire-DT® card)
10
Normally 6
Yes
Yes

Rated operational voltage U AUX
Permissible range

V DC
V DC

–
–

Input current UAUX at 24 V DC
Ripple
Voltage dips (IEC/EN 61131-2)
Protection against polarity reversal

A
%
ms

–
–
–

V

–
–

Voltage
Short-circuit protection, SmartWire-DT® side

–

Us

24, -15 %, +20 % (Derating from > 40 °C)
20.4…28.8, at 45 °C: 21…28.8,
at 50 °C: 21.6…28.8,
at 55 °C: 22.2…27.6
Normally 3
̰5
10
Yes
Yes
No, external 3 A fuse or FAZ-Z3

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

37

1.4

Connection system SmartWire-DT®

SWIRE-…
1

SWIRE-4DI-2DO-R

SWIRE-GW-MB

LED indicators
Operational

Ready: green

Ready: green

Power supply, SmartWire-DT® contactors

–

U Aux : green

MODBUS status

–

MODBUS: yellow

SmartWire-DT® status
Output status

–
Q1, Q2: green

SmartWire-DT®: green
–

V DC

4
17

–
–

mA

5

–

Connection floating contacts
Number
Rated voltage (internal supply)

Ue

Input current at “1” signal, typically
Potential isolation

–

Yes

< 2.8

–

Terminal type

–

SUB-D, 9 pole, socket RS232/RS485

Station address
Address setting

–
–

1 … 31
DIP switches

–

Yes

–

Yes

Function

–
–

Bus protocol
Bus Terminating Resistors
Baud rate

–
–
–

Yes
MODBUS-RTU
Slave
MODBUS-RTU
can be connected via plug
Adjustable up to 57.6 (9.6/19.2/38.4)
kbit/s

Max. cable length
MODBUS

m

Potential isolation

From UAUX power supply
From UGateway power supply
To SmartWire-DT®

SmartWire-DT®
Terminal type

Plug, 6-pole

Data/power cable

6-core ribbon cable

6-core ribbon cable

Max. 4
Plug connectors

Max. 4
No

Station address

1…16

Automatic assignment

Station
Address setting

Max. 4 SmartWire-DT® modules per line. Max. 16
automatically via SmartWire-DT®
None

Maximum cable length, SmartWire-DT® system
Bus termination

m

Plug, 6-pole

Potential isolation

From UAUX power supply
From UGateway power supply
Function
Data transfer time, SmartWire-DT® system
Write switch

No

No

No

No

SmartWire-DT® slave

SmartWire-DT® master

Normally 20 ms for all stations

–

Normally 10 ms per station

–

V AC

4000

–
–

Read status information
Relay outputs
Rated impulse withstand voltage
Overvoltage category/pollution degree
Rated insulation voltage

U imp
Ui

V

III/3
250

Rated operating voltage
Making capacity

Ue

V
A

250
30

–
–

Breaking capacity
Rated operational current

380/400 V

A

10

–

Ie

A

3

–

Ie
I th

A
A

3
6

–
6

AgG/gL

10

–

AC-15, 250 V
DC-12, 30 V
Conventional thermal current
Short-circuit rating without welding
max.fuse

38

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Motor-starter combinations
DOL starters, reversing starters

1.4

MSC-D, MSC-R, MSC-DE(A)
1

MSC-D, MSC-R, MSC-DE(A)
IEC/EN 60947-4-1, VDE 0660
UL 508 (please enquire)
CSA C 22.2 No. 14 (please enquire)
º
90

Rated impulse withstand voltage

Further technical data

Overvoltage category/pollution degree
Rated operating voltage
Motor protective circuit breaker
PKZM0, PKE
Contactors DILM

U imp
Ue

V AC

6000

V

III/3
230 - 415
Chapter 1.3

º

º
90

Main contacts

90

Mounting position

º

Standards

90

General

Chapter 1.1

Dimensions
DOL starters
MSC-D-…-M7[…15]…

MSC-D-…-M17[…32]…
67

46

46

67

228

180

180

6

95

45

45

97.4
123.4

MSC-D-…-M7[…15]BBA…

MSC-D-…-M17[…32]BBA…
67

95

200

180

60

60

200

180

60

60

40

40

67

45

45

97.4
10

10

35

35
63

63

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

39

1.4

Motor-starter combinations
DOL starters, reversing starters

Reversing starters
MSC-R-…-M7[…12]…

MSC-R-…-M17[…32]…
67

46

46

67

114

228

180

180

6

95

90

90

97.4
123.4

MSC-R-…-M7[…12]BBA…

MSC-R-…-M17[…32]BBA…
67

60

60

114

180

180

60

60

40

40

67

90

95

90

97.4
10

10

35

35

63

63

DOL starters
MSC-DE(A)-...-M7[...12]...

MSC-DE(A)-...-M7[...12]...

102

102

97

97

242

196

189

78

50

1

45

45

128

40

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Connection system SmartWire-DT®
DOL starters, reversing starters

1.4

Modules
SWIRE-DIL

4

38

1

45

50
12

70

SWIRE-PF , SWIRE-4DI-2DO-R

110

90

102

7.5

4.5

66
74

M4
7.5
35.5

Gateways
SWIRE-GW-DP..., SWIRE-GW-MB

110

90

4.5

M4
7.5
35.5

102

7.5

105
109

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

41

Control relays XTRG
Contents, system overview

Control relays XTRG

2.1

Control relays XTRG
System overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Basic devices XTRG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
3 2
3
4

Control relays XTRG
Product description

Features

System overview

Standards and certifications

Part of the E Line family of
controls, the XTRG control relay
offers space savings, enhanced
reliability and more efficient use
of materials. Rated to operate
thermal currents up to 10A, AC
voltages up to 660V or DC
voltages up to 250V, the XTRG
contactor relay offers optimum
performance in a compact
package.

• 10A Control relay
• 690V Insulation rating
• 660VAC or 250VDC
Operational voltage
• Up to 5 sets of normally
open or normally closed
contacts with add-on blocks
• All common AC control
voltages
• DIN rail or panel mount
options
• Unique 27mm design

Control relays are used to
remotely switch small loads or
in complex control schemes.
The XTRG relay can be
integrated with contactors from
the E Line ramily of motor
controls to create compact,
efficient control panels for a
multitude of applications.

•
•
•
•

GB 14048
IEC/EN 60947
CCC
CE

Accessory overview
3

1X

1
1X

2
1 Contactor relay
2 Auxiliary contact modules
3 Surge suppressor

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

2

2.1
XTRG

Control relays XTRG
Basic devices / Auxiliary contact modules, actuating voltages

Control relays
Connection
type

2

Contact

Rated operational
current
AC-15 Ie (A)

N/O=Normally open
N/C=Normally closed

220V
230V
240V

380 V
400 V
415 V

Conventional Circuit
thermal
symbol
current,
open, 40°C
Ith (A)

Can be
combined with
auxiliary contact
module

AC operation
Part no.
Article no.

Standard
package

Actuating voltage
220V 50HZ

Screw terminals

3 N/O

-

4

1.9

10

XTCGXFAC10
XTCGXFAC..

XTRG10B30DT
168044

1 piece

Screw terminals

2 N/O

1 N/C

4

1.9

10

XTCGXFAC10
XTCGXFAC..

XTRG10B21DT
167927

1 piece

Screw terminals

1 N/O

2 N/C

4

1.9

10

XTCGXFAC10
XTCGXFAC..

XTRG10B12DT
167968

1 piece

Screw terminals

-

3 N/C

4

1.9

10

XTCGXFAC10
XTCGXFAC..

XTRG10B03DT
167978

1 piece

Alternate actuating voltages
Coil Voltage

3NO

2NO/ 1NC

1NO/ 2NC

3NC

24VAC 50Hz

XTRG10B30B5
168040

XTRG10B21B5
167923

XTRG10B12B5
167933

36VAC 50Hz

XTRG10B30DS
168041

XTRG10B21DS
167924

XTRG10B12DS
167934

XTRG10B03B5
167974
XTRG10B03DS
167975

48VAC 50Hz

XTRG10B30C5
168042
XTRG10B30E5
168043

XTRG10B21C5
167925
XTRG10B21E5
167926

XTRG10B12C5
167966
XTRG10B12E5
167967

XTRG10B03C5
167976
XTRG10B03E5
167977

XTRG10B30DT
168044
XTRG10B30DU
168047

XTRG10B21DT
167927
XTRG10B21DU
167930

XTRG10B12DT
167968
XTRG10B12DU
167971

XTRG10B03DT
167978
XTRG10B03DU
167936

110VAC 50Hz
220VAC 50Hz
380VAC 50Hz

Auxiliary contact,
top mounting

Auxiliary contact modules
Connection
type

Conventional
thermal current
open, 40°C

Contact

Circuit
symbol

N/O=Normally open
N/C=Normal closed

Can be
combined with
control relay

Part no.
Article no.

Standard
package

XTCGXFAC10
167939
XTCGXFAC01
167940

1 piece

XTCGXFAC20
167941
XTCGXFAC11
167942

1 piece

XTCGXFAC02
167943

1 piece

Ith = Ie AC-1
A

Screw
terminals

1 pole

10

1 N/O

-

XTRG10B..

Screw
terminals

1 pole

10

-

1 N/C

XTRG10B..

Screw
terminals

2 pole

10

2 N/O

-

XTRG10B..

Screw
terminals

2 pole

10

1 N/O

1 N/C

XTRG10B..

Screw
terminals

2 pole

10

-

2 N/C

XTRG10B..

Coil surge supressor
Coil voltage

RC

Varistor

24-48V

XTCGXRSCN2
167946
XTCGXRSCDV
167947

XTCGXVSCN2
167949
XTCGXVSCDV
167950

XTCGXRSCCM
167948

XTCGXVSCCM
167951

110-220V
380-440V

3

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1 piece

1 piece

Control relays XTRG
Technical data

2.1

General
XTRG10B..

XTCGXFAC..

2

IEC/EN 60947, GB 14048

Standards
Mechanical lifespan
AC operated

Operations

Maximum operating frequency
Maximum operating frequency
Climatic proofing

x 106

Operations/h

10

10

600
600
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Ambient temperature
Operation
Storage

°C
°C

Protection type
Weight approximate weight

kg

-5~40
-25~55
IP20
0.17

-5~40
-25~55
IP20
0.02

XTRG10B..

XTCGXFAC..

VAC

6000

6000

Ui

VAC

III/3
690

III/3
690

Ue

VAC

660

660

Ie

A

6

6

Ie
Ie
Ie
Ie
Ie

A
A
A
A
A

4
1.9
1.5
1.4
1.2

4
1.9

Ie
Ie
Ith

A
A
A

0.55
0.27
10

0.55
0.27
10

Operations

x 106

1

1

Contacts
Rated impulse withstand voltage
Overvoltage category/degree of pollution
Rated insulation voltage
Rated operational voltage
Rated operational current
AC-15
120V
240V
380V
480V
500V
600V
DC-13
125V
250V
Conventional thermal current
Electrical lifespan
at Ue=230V, AC-15, 3A

Uimp

Magnet system
XTRG10B..

Voltage tolerance
AC operated
Power consumption

Pick-up
Pick-up
Sealing
Sealing

x Uc
VA
VA
W

0.85-1.1
30
6
2

Terminals
XTRG10B..
XTCGXFAC..

mm2

mm2

Nm

mm2

Nm

0.75-2.5

0.75-2.5

0.8

0.75-2.5

0.8

0.75-2.5

0.75-2.5

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

4

2.1

Contactors XTCG
Contents

Contactors XTCG
System overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors
Basic devices XTCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical data
Contactors XTCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contactors XTCG

2

Contactors XTCG
Product description

Features

System overview

Standards and certifications

The XTCG is the flagship of the
E Line family of motor controls.
The XTCG contactor offers
space savings, enhanced
reliability and more efficient use
of materials. Boasting AC-3
ratings up to 32A @ 400V and
with a maximum operating
voltage of 660V, XTCG offers
tremendous performance in a
small package.

• Technologically advanced
contact design
• 690V insulation rating
• Operating voltage up to
660VAC
• Up to (3) add on auxiliary
contact modules
• All common AC control
voltages
• DIN rail or panel mount
options
• Unique space saving design

3 phase contactors are used to
start motors or control industrial
loads. The E Line family of
contactors allows the starting of
motors up to 15kW, and when
combined with an XTOD
overload relay or PKZC motor
protective circuit breaker offers
a complete package of
protection and control for long
life and reliable operation.

•
•
•
•

GB 14048
IEC/EN 60947
CCC
CE

Accessory overview
7-12A Frame

18-32A Frame
3

1X

3

1X

18-32A Frame with mechanical
interlock

1

4

1

1X

2

5

1X

2

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1
2
3
4

Contactor relay
Auxiliary contact modules
Surge suppressor
Interlocking kit

5
6
6
6
7
7

2.1

Contactors XTCG
Basic devices / Auxiliary contact modules, actuating voltages / Accessories

XTCG

3-pole contactors
Conventional
thermal current,
open, 40 °C
Ith = Ie AC-1(A)

Connection
type

Rated
operational
current
AC-3 Ie (A)
380V

Screw
terminals

7

2.2

3

3.5

20

Screw
terminals

9

2.5

4

4.5

20

Screw
terminals
Screw
terminals
Screw
terminals
Screw
terminals

12

3.5

5.5

5.5

20

18

5

7.5

7.5

25

25

7.5

11

11

35

32

10

15

15

40

Max motor rating for
3-phase motors,
50-60Hz AC-3 P kW
220V
380V
660V

Circuit
symbol

AC operation
Part no.
Article no.
Actuating voltage
220V 50Hz

2

XTCG007B00DT
167984
XTCG009B00DT
167994
XTCG012B00DT
168004
XTCG018C00DT
168014
XTCG025C00DT
168024
XTCG032C00DT
168034

Standard package: 1piece

Alternate actuating voltages
Coil voltage

7A

9A

12A

18A

25A

32A

24VAC 50Hz

XTCG007B00B5
167980
XTCG007B00DS
167981

XTCG009B00B5
167990
XTCG009B00DS
167991

XTCG012B00B5
168000
XTCG012B00DS
168001

XTCG018C00B5
168010
XTCG018C00DS
168011

XTCG025C00B5
168020
XTCG025C00DS
168021

XTCG032C00B5
168030
XTCG032C00DS
168031

XTCG007B00C5
167982
XTCG007B00E5
167983
XTCG007B00DT
167984
XTCG007B00DU
167987

XTCG009B00C5
167992
XTCG009B00E5
167993
XTCG009B00DT
167994
XTCG009B00DU
167997

XTCG012B00C5
168002
XTCG012B00E5
168003
XTCG012B00DT
168004
XTCG012B00DU
168007

XTCG018C00C5
168012
XTCG018C00E5
168013
XTCG018C00DT
168014
XTCG018C00DU
168017

XTCG025C00C5
168022
XTCG025C00E5
168023
XTCG025C00DT
168024
XTCG025C00DU
168027

XTCG032C00C5
168032
XTCG032C00E5
168033
XTCG032C00DT
168034
XTCG032C00DU
168037

Can be
combined with
control relay

Part no.
Article no.

Standard
package

36VAC 50Hz
48VAC 50Hz
110VAC 50Hz
220VAC 50Hz
380VAC 50Hz

Auxiliary contact,
top mounting

Auxiliary contact modules
Conventional
thermal current
open, 40°C

Connection
type

Contact

Circuit
symbol

N/O=Normally open
N/C=Normal closed

Ith = Ie AC-1
A

Screw
terminals

1 pole

10

1 N/O

-

XTCG10B...

XTCGXFAC10
167939

1 piece

Screw
terminals

1 pole

10

-

1 N/C

XTCG10B...

XTCGXFAC01
167940

1 piece

Screw
terminals

2 pole

10

2 N/O

-

XTCG10B...

1 piece

Screw
terminals

2 pole

10

1 N/O

1 N/C

XTCG10B...

XTCGXFAC20
167941
XTCGXFAC11
167942

Screw
terminals

2 pole

10

-

2 N/C

XTCG10B...

XTCGXFAC02
167943

1 piece

1 piece

Mechanical interlock

Coil surge supressor
Coil voltage

RC

Varistor

7-12A

18-32A

24-48V

XTCGXRSCN2
167946

XTCGXVSCN2
167949

XTCGXMLB
167944

XTCGXMLC
167945

110-220V

XTCGXRSCDV
167947

XTCGXVSCDV
167950

380-440V

XTCGXRSCCM
167948

XTCGXVSCCM
167951

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

6

2.1

Contactors XTCG
Technical data

General
XT Basic device

CG007

CG012

CG018

CG025

CG032

10

10

10

10

600
600
600
Damp heat,constant,to IEC60068-2-78
Damp heat,cyclic,to IEC60068-2-30

600

600

600

-5~40
-25~55
IP20
0.17

-5~40
-25~55
IP20
0.17

-5~40
-25~55
IP20
0.17

-5~40
-25~55
IP20
0.35

-5~40
-25~55
IP20
0.35

-5~40
-25~55
IP20
0.35

0.75-2.5
M3.5
0.8
M3.5
0.8

0.75-2.5
M3.5
0.8
M3.5
0.8

0.75-2.5
M3.5
0.8
M3.5
0.8

0.75-2.5
M5
2
M3.5
0.8

0.75-2.5
M5
2
M3.5
0.8

0.75-2.5
M5
2
M3.5
0.8

V AC
V AC
A

6000
III/3
690
660
70

6000
III/3
690
660
90

6000
III/3
690
660
120

6000
III/3
690
660
180

6000
III/3
690
660
250

6000
III/3
690
660
320

A

56

72

96

144

200

256

Op.

1,500,000

1,500,000

1,500,000

1,000,000

1,000,000

1,000,000

Op.

100,000

100,000

100,000

100,000

100,000

100,000

Pick-up

x Uc

0.85-1.1

0.85-1.1

0.85-1.1

0.85-1.1

0.85-1.1

0.85-1.1

Pick-up
Sealing
Sealing

VA
VA
W

30
6
2

30
6
2

30
6
2

80
8.1
2.4

80
8.1
2.4

80
8.1
2.4

Standards
2 Lifespan, mechanical
AC operated
Operations
Operating frequency
Operations/h
AC operated
Climatic Proofing

x 106

Ambient temperature
Operation
Storage
Protection type
Weight
Terminal capacity of main cable

Nm
Nm

380V

Electrical lifespan
AC-3

Power consumption
of coil in a cold
state and 1.0 xUc

kg

mm2

Main contacts
Uimp
Rated impulse withstand voltage
Overvoltage category / pollution degree
Rated insulation voltage
Ui
Rated operational voltage
Ue
Making capacity
380V
(cos ij to IEC/EN60947)

AC-4
Magnet systems
Voltage tolerance
AC operated

°C
°C

10

10

AWG

Solid/stranded
Terminal capacity of control circuit cable
Main cable connection screws / bolts
Tightening torque
Control circuit cable connection screws / bolts
Tightening torque

Breaking capacity
(cos ij to IEC/EN60947)

CG009

IEC/EN 60947, GB 14048

V AC

Terminals

Auxiliary contact
XTCGXFAC..

Uimp
Rated impulse withstand voltage
Overvoltage category/degree of pollution
Ui
Rated insulation voltage
Ue
Rated operational voltage
Rated operational current

VAC
VAC
VAC

7-12A

6000
III/3
690
660

mm2

AC-15

120V
240V
380V

Ie
Ie
Ie

A
A
A

6
4
1.9

Ie
Ie
Ith

A
A
A

0.55
0.27
10

x 106

1

mm2

0.75-2.5

0.75-2.5

0.75-2.5

0.75-2.5

Nm

0.8

Aux Contact
mm2

0.75-2.5

Nm

0.8

18-32A

DC-13

125V
250V
Conventional thermal current
Electrical lifespan

at Ue=230V, AC-15, 3A

7

Operations

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

mm2

mm2

1-6
(1 - 10)*

1-6
(1 - 10)*

1-4
(1 - 10)*

1-4
(1 - 10)*

Nm

2

Aux Contact
mm2

0.75-2.5

Nm

0.8

Dimensions

2.1

Contactors
18-32A Frame

7-12A Frame

2
3hĭ4

3hĭ4

113
82

97.5
35.3

77.5
35.3

70.1

Auxiliary contact module
1 Pole

2 Pole

Thermal overload relay + mounting adapter
XTOD..CC1S

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

8

2.1

Dimensions

Control Relay

2

Surge suppressor

3 × ĭ4

Mechanical interlock
7-12A Frame

18-32A Frame

9

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

2.2

Thermal overload relays XTOD
Contents

Thermal overload relays XTOD

2

Thermal overload relays XTOD
System overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermal overload relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Thermal overload relays XTOD
Product description

Features

System overview

Standards and certifications

XTOD thermal overload relays
offer precision motor protection
with phase loss protection and
ambient temperature
compensation. The seperate
mount design allows for
flexibility and the units can be
mounted on DIN rail or directly
on the panel adjacent the motor
contactor.

• Precision motor protection up
to 32A
• Integral 1NO/1NC contact for
contactor control and alarm
signal
• Phase loss protection
• Ambient temperature
compensation
• DIN rail or panel mount
options

Thermal overload relays provide
protective features for 1 or 3
phase motors. The relay
monitors the operating current
of the motor and switched the
contactor off in the event of an
overload situation. It also
protects the motor from
damage during phase loss.

•
•
•
•

2

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

GB 14048
IEC/EN 60947
CCC
CE

2
3
3
5

Thermal overload relays XTOD
Thermal overload relays

2.2

Thermal overload relays
For use with

XTOD..CC1S

XTCG007
XTCG009
XTCG012
XTCG018
XTCG025
XTCG032

Setting range
of overload
releases Ir (A)

Seperate mounting

Circuit
symbol

Seperate mounting
Seperate mounting

97 95

0.3~0.45

2

4

6

2

4

6

Seperate mounting
Seperate mounting
Seperate mounting

4

6

4

6

4

6

4

6

4

6

2

4

6

2

4

6

2

4

6

2

4

6

1 N/C

1 N/O

1 N/C

1 N/O

1 N/C

1 N/O

1 N/C

1 N/O

1 N/C

1 N/O

1 N/C

1 N/O

1 N/C

1 N/O

1 N/C

1 N/O

1 N/C

98 96

98 96
97 95

22~30

1 N/O

98 96

97 95

17~24

1 N/C

98 96

97 95

12.5~18

1 N/O

98 96

97 95

8.5~12.5

1 N/C

98 96

97 95

5.5~8.5

1 N/O

98 96

97 95

4.0~6.0

1 N/C

98 96

97 95

3.5~5.0

1 N/O

98 96

97 95

2.4~3.6

1 N/C

98 96

97 95

2

Seperate mounting

6

1.8~2.7

2

Seperate mounting

4

1 N/O

98 96

97 95

2

Seperate mounting

6

1.4 ~2.1

2

Seperate mounting

4

1 N/C

98 96

97 95

1.0 ~1.5

1 N/O

98 96

97 95

0.67~1.0

2

Seperate mounting

6

0.45 ~0.67

2

Seperate mounting

4

97 95

2

Seperate mounting

Part no.
Article no.

Standard
package

XTODP45CC1S
167952
XTODP67CC1S
167953
XTOD001CC1S
167954
XTOD1P5CC1S
167955
XTOD2P2CC1S
167956
XTOD2P7CC1S
167957
XTOD3P6CC1S
167958
XTOD005CC1S
167959
XTOD006CC1S
167960
XTOD8P5CC1S
167961
XTOD013CC1S
167962
XTOD018CC1S
167963
XTOD024CC1S
167964
XTOD030CC1S
167965

1 piece

2

N/O =Normally open
N/C =Normally closed

2

Seperate mounting

Auxiliary
contact

98 96

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

1 piece
1 piece
1 piece
1 piece
1 piece
1 piece
1 piece
1 piece
1 piece
1 piece
1 piece
1 piece
1 piece

3

2.2

Thermal overload relays XTOD
Technical data

General
XTOD..CC1S

2 Standards

IEC/EN 60947, GB 14048
Damp heat, constant, to IEC60068-2-78
Damp heat, cyclic, to IEC60068-2-30

Climatic Proofing
Ambient temperature
Open
Enclosed
Temperature compensation
Weight
Protection type

°C

-25~55

°C
°C
kg

-25~40
-5~40
0.15
IP20

Main contacts
XTOD..CC1S

Rated impulse withstand voltage
Overvoltage category/pollution degree
Rated insulation voltage
AC
Rated operational voltage
Overload release setting range
Terminal capacity
Solid

Uimp

VAC

6000
III/3

Ui
Ue

VAC
VAC
A

690
600
0.3-30

mm2

1 x (1-6)
2 x (1-6)

Flexible with ferrule

mm2

1 x (1-6)
2 x (1-6)

Solid/stranded
Terminal screw
Tightening torque

AWG
Nm

M4
1.2

Auxiliary and control circuits
XTOD..CC1S

Rated impulse withstand voltage
Overvoltage category/pollution degree

Uimp

V

6000
III/3

Terminal capacity
Solid

mm2

1 x (1-6)
2 x (1-6)

Flexible with ferrule

mm2

1 x (1-6)
2 x (1-6)

Solid/stranded
Terminal screw
Tightening torque
Rated insulation voltage
Rated operational voltage

AWG

Conventional thermal current
Rated operational current
AC-15
120V
220/240V
380V
480V
500V
600V
DC-13
125V
250V

4

Ui
Ue

Nm
VAC
VAC

M3.5
0.8
690
600

Ith

A

10

Ie
Ie
Ie
Ie
Ie
Ie

A
A
A
A
A
A

6
3
1.9
1.5
1.4
1.2

Ie
Ie

A
A

0.55
0.27

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

Thermal overload relays XTOD
Dimensions

2.2

Dimensions
Thermal overload relay + mounting adapter
XTOD..CC1S

2

AUTOMATION AND CONTROL www.eaton.com/seasia-electrical

5



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0 (Windows)
Create Date                     : 2013:06:27 12:27:32+08:00
Modify Date                     : 2013:06:27 13:28:48+08:00
Metadata Date                   : 2013:06:27 13:28:48+08:00
Document ID                     : uuid:6D1F8ECDE1DEE21199E597DDE4498DA5
Instance ID                     : uuid:b95adc77-214d-447f-9988-5f7e3484bf68
Derived From Instance ID        : uuid:4294c9b0-518f-4dc8-95d2-0b7cda0e333c
Derived From Document ID        : uuid:0c7f1211-f782-4fe6-a4cd-74cfa23098db
Format                          : application/pdf
Title                           : xStart-1-1.eps
Creator                         : Administrator
Page Count                      : 309
Author                          : Administrator
EXIF Metadata provided by EXIF.tools

Navigation menu