XStart 1
2014-09-08
: Pdf 618755-Attachment 618755-Attachment 015082 Batch5 unilog
Open the PDF directly: View PDF
.
Page Count: 309
| Download | |
| Open PDF In Browser | View PDF |
Contactors and starters xStart series contactors xStart series 1.1 xStart series overload relays Motor protective circuit breaker PKZ xStart series overload relays Bimetal relay ZE, ZB, Z5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Overload relay ZW7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Electronic overload relays ZEB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 EMT6 thermistor overload relay for machine protection . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C441 overload and monitoring relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 1.3 xStart series motor-protective circuit-breakers Motor-protective circuit-breakers PKZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Motor-protective circuit-breakers PKE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 DC string circuit-breaker PKZ-SOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 DC switch-disconnectors P-SOL, SOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 1.4 Motor-starter combinations Motor-starter combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E Line thermal overload relay 1 E Line series 2.2 E Line contactors 1 1 1.2 2.1 Motor-starter combinations xStart series contactors Mini contactor relays, contactor relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contactors DIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 E Line contactors Control relays XTRG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contactors XTCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 5 E Line thermal overload relay Thermal overload relays XTOD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 1 Mini contactor relays, contactor relay, contactors Continual operation requires high operational reliability in the components used. The DILM contactor achieves the best lifespan values in AC-3 applications and is ideal for heavy AC-4 jogging. Mini contactor relay DILE…,contactor relays, contactors up to 12 A AC-3 at 400 V • Compact dimensions for the highest packing densities • Extended performance range up to 5.5 kW at 400 V AC and DC contactor system DILM…, contactor relays, 3 pole contactors up to 170 A AC-3 at 400 V, 4 pole contactors up to 200 A AC-1 • • • • • • • • Eaton after sales service Testing switching devices in compliance with regulations applicable to this technology See catalog Easier engineering through identical construction sizes for AC- and DC-operated contactors Energy savings and higher packing density in control panel due to minimized heat dissipation High wiring security through doubled box terminals Less coupler relays: direct actuation from the PLC for contactors up to 32 A Easy engineering through integrated suppressor circuits for DC Uniform accessories for 3- and 4-pole contactors Mechanical interlock double conductor run mountable without additional separation gap Direct fieldbus connection through the communication system SmartWire-DT®, through plug-in type protective module High rated contactors - contactors up to 1600 A AC-3 at 400 V, contactors up to 2600 A AC-1 • • • • • Compact dimensions with high switching power Direct actuation from the PLC saves coupler relays Easy engineering through wide range coils Cost and energy savings for control panel ventilation due to reduced heat dissipation Long lifespan through vacuum technology from 580 A SmartWire-DT® The DIL product range offers contact elements which can be connected to the SmartWire-DT® communication system. Protective modules, Page 62 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Mini contactors, relays, contactors Contents Ordering Mini contactor relays DILER, DILEEM, DILEM Mini contactor relays, contactors . . . . . . . . . . . . . . . . Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Actuating voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . DILA contactor relays Contactor relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . . Actuating voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 6 8 66 10 12 68 Technical overview Contactors DILM, DILH . . . . . . . . . . . . . . . . . . . . . . . 14 System overview Contactors DILM, DILH . . . . . . . . . . . . . . . . . . . . . . . 16 Ordering Contactors DILM, DILH Basic devices up to 170 A . . . . . . . . . . . . . . . . . . . . . Complete units up to 170 A . . . . . . . . . . . . . . . . . . . . Standard devices greater than 170 A . . . . . . . . . . . . . Comfort devices greater than 170 A . . . . . . . . . . . . . Basic devices up to 200 A, 4 pole . . . . . . . . . . . . . . . Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . . 18 24 28 30 34 36 Engineering Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . . 40 Ordering DILK contactors for capacitors . . . . . . . . . . . . . . . . . . 41 Engineering Contactors for power factor correction . . . . . . . . . . . 42 Ordering Star-delta combinations SDAINL . . . . . . . . . . . . . . . . 44 Engineering Star-delta combinations SDAINL . . . . . . . . . . . . . . . . 46 Ordering DIUL reversing combinations . . . . . . . . . . . . . . . . . . . 48 Description CMD contactor monitoring device . . . . . . . . . . . . . . . 64 Ordering CMD contactor monitoring device . . . . . . . . . . . . . . . 64 Ordering DILM contactor relays, DILM, DILH contactors suppressor circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Ordering Actuating voltages contactors DILM, DILH Basic devices up to 170 A . . . . . . . . . . . . . . . . . . . . Basic devices up to 200 A, 4 pole . . . . . . . . . . . . . . Contactors up to 150 A with electronic actuation . . . . . . . . . . . . . . . . . . . . . Replacement coils . . . . . . . . . . . . . . . . . . . . . . . . . . Comfort devices greater than 170 A . . . . . . . . . . . . Standard devices greater than 170 A . . . . . . . . . . . . Electronic modules including coil . . . . . . . . . . . . . . . Contactors for capacitors . . . . . . . . . . . . . . . . . . . . . Engineering Contact travel diagrams . . . . . . . . . . . . . . . . . . . . . . Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL/CSA-approved rating data . . . . . . . . . . . . . . . . . . UL/CSA special purpose ratings . . . . . . . . . . . . . . . UL/CSA short circuit current rating . . . . . . . . . . . . Contactors for resistive loads . . . . . . . . . . . . . . . . . . Electrical life span . . . . . . . . . . . . . . . . . . . . . . . . . . . Short-time loading . . . . . . . . . . . . . . . . . . . . . . . . . . Operating frequency . . . . . . . . . . . . . . . . . . . . . . . . . Switching of DC current . . . . . . . . . . . . . . . . . . . . . . Technical data Mini contactor relays, contactor relays . . . . . . . . . . . Contactor monitoring device . . . . . . . . . . . . . . . . . . Basic devices up to 170 A . . . . . . . . . . . . . . . . . . . . Basic devices up to 200 A, 4 pole . . . . . . . . . . . . . . Comfort devices greater than 170 A . . . . . . . . . . . . Standard devices greater than 170 A . . . . . . . . . . . . Contactors for capacitors . . . . . . . . . . . . . . . . . . . . . Contactors up to 150 A with electronic actuation . . . . . . . . . . . . . . . . . . . . . Lighting contactors . . . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions Mini contactor relays . . . . . . . . . . . . . . . . . . . . . . . . Contactor relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . Basic devices up to 170 A . . . . . . . . . . . . . . . . . . . . Basic devices up to 200 A, 4 pole . . . . . . . . . . . . . . Contactors larger than 170 A . . . . . . . . . . . . . . . . . . Contactors for capacitors . . . . . . . . . . . . . . . . . . . . . Lighting contactors . . . . . . . . . . . . . . . . . . . . . . . . . . Contactor combinations . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 69 74 76 71 77 77 77 77 78 79 80 81 82 84 86 90 91 92 93 96 104 120 112 112 123 126 125 128 128 130 131 131 133 134 136 136 137 138 1 1 1.1 1 Contactors Mini contactors, relays Ordering Screw terminals DILER mini contactor relays Rated operational current AC-15 220 V 230 V 240 V Conventional free air thermal current 380 V 400 V 415 V Ie Ie I th A A A 6 3 10 Contact N/O = normally open contact NC = normally closed contact 4 N/O – Distinctive number Circuit symbol 40E A1 13 23 33 43 For use with DILE… A2 14 24 34 44 3 N/O 1 NC 31E A1 13 21 33 43 DILE… A2 14 22 34 44 2 N/O 2 NC 22E A1 13 21 31 43 DILE… A2 14 22 32 44 Notes Coil terminal marking as specified in EN 50005 Contact numbers to EN 50011 The following applies to DC-operated contactors: • Integrated diode-resistor combination • Coil rating 2.6 W 2 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 3211-03 UL Listed, CSA certified Contactors Mini contactors, relays 1.1 1 AC operation Part no. Article no. DC operation Price See price list Part no. Article no. DILER-40(230V50Hz) 051759 DILER-40-G(24VDC) 010223 DILER-31(230V50Hz) 051768 DILER-31-G(24VDC) 010157 DILER-22(230V50Hz) 051777 DILER-22-G(24VDC) 010042 Price See price list Std. pack Notes 5 off With screw terminals: 1 2 Accessories 1 Suppressor 2 Auxiliary contact modules Further actuating voltages Page 8 6 66 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 3 1.1 Contactors Mini contactors, relays DILEM contactors 1 3 pole with auxiliary contact Screw terminals Rated operational current AC-3 Max. motor rating for three-phase motors, 50 - 60 Hz AC-3 380 V 400 V Ie 220 V 230 V P 380 V 400 V P 660 V 690 V P 220 V 230 V P 380 V 400 V P 660 V 690 V P A kW kW kW kW kW kW A A 6.6 1.5 3 3 1.1 2.2 2.2 20 16 6.6 Circuit symbol Open Enclosed I th = I e I th = I e N/O = normally open contact NC = normally closed contact 3 3 1.1 2.2 2.2 20 1 N/O 16 – – 1 NC 4 4 1.5 3 3 20 16 1 N/O – 9 2.2 4 4 1.5 3 3 20 16 – 1 NC 9 3.5 3.5 2.2 5.5 5.5 4 6.5 6.5 4 2 2 1.5 3 3 3 2.2 2.2 3 20 20 20 16 1 N/O 16 – 16 – – 1 NC – 3 5 13 A2 2 4 6 14 A1 1 3 5 A2 2 4 6 22 A1 1 3 5 13 A2 2 4 6 14 A1 1 3 5 A2 2 4 6 22 A1 1 3 5 13 A2 2 4 6 14 A1 1 3 5 A2 2 4 6 22 A1 1 3 5 7 A2 2 4 6 8 A1 1 21 21 21 1) 2) Information relevant for export to North America Information relevant for export to North America Product Standards UL File No. UL CC CSA File No. CSA Class No. NA Certification See also For use with AC-4 2.2 12 4 Contact 9 12 4 pole Screw terminals 1.5 Conventional thermal current I th = Ie AC-1 at 50 °C IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 3211-04 UL Listed, CSA certified Page 80 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical …DILEM DILE… DILE… …DILEM DILE… DILE… …DILEM DILE… DILE… …DILEM DILE… Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 UL File No. NLDX UL CCN 012528 CSA File No. 2411-03,3211-04 CSA Class No. UL Listed, request filed for CSA NA Certification Contactors Mini contactors, relays 1.1 1 AC operation Part no. Article no. DC operation Price See price list Part no. Article no. DILEEM-10(230V50Hz) 1) 051608 DILEEM-10-G(24VDC)1) 051643 DILEEM-01(230V50Hz) 1) 051633 DILEEM-01-G(24VDC)1) 051650 DILEM-10(230V50Hz) 1) 051786 DILEM-10-G(24VDC)1) 010213 DILEM-01(230V50Hz) 1) 051795 DILEM-01-G(24VDC)1) 010343 DILEM12-10(230V50Hz) 2) 127075 DILEM12-10-G(24VDC) 2) 127132 DILEM12-01(230V50Hz) 2) 127091 DILEM12-01-G(24VDC) 2) 127137 DILEM4(230V50Hz) 1) 051804 DILEM4-G(24VDC)1) 012701 Price See price list Std. pack Notes 5 off With screw terminals: 2 3 5 off 1 Accessories 1 Overload relay 2 Suppressor 3 Auxiliary contact module Enclosures Further actuating voltages Accessories Page Chapter 1.2 8 6 66 8 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 5 1.1 1 Screw terminals Mini contactor relays Auxiliary contact modules DILE Auxiliary contact modules Contact Rated operational current N/O = normally open contact S F = NO early-make NC = normally closed contact Ö S = NC late-break AC-15 220 V 230 V 240 V Ie Distinctive number/type of combinations with basic device DILER-40(-G) DILER-31(-G) DILER-22 A A A – – 2 NC – 4 2 10 – – – 1 N/O – 1 NC – 4 2 10 – – – 4 pole 2 N/O – 2 NC – 4 2 10 – – – 2 pole – – 2 NC – 4 2 10 42E 33 24 1 N/O – 1 NC – 4 2 10 51E 42 33 2 N/O – – – 4 2 10 60E 51 42 – 1 SF – 1 ÖS 4 2 10 51 42 33 – – 4 NC – 4 2 10 44E 35 26 1 N/O – 3 NC – 4 2 10 53E 44 35 2 N/O – 2 NC – 4 2 10 62E 53 44 3 N/O – 1 NC – 4 2 10 71E 62 53 4 N/O – – – 4 2 10 80E 71 62 1 N/O 1 SF 1 NC 1 ÖS 4 2 10 62 53 44 2 pole 4 pole Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification 6 380 V 400 V 415 V Ie Conventional thermal current I th IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 3211-03 UL Listed, CSA certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Mini contactor relays Auxiliary contact modules 1.1 1 Circuit symbol 21 31 22 32 21 33 Can be combined with contactor Part no. Article no. DILEM-10(-G)(…) DILEM-4(-G)(…) DILEEM-10(-G)(…) DILEM12-10(-G)(…) 02DILEM 010064 5 off With interlocked opposing contacts 11DILEM 010080 5 off With interlocked opposing contacts 22DILEM 010112 5 off With interlocked opposing contacts 02DILE 010240 5 off With interlocked opposing contacts 11DILE 010224 5 off With interlocked opposing contacts 20DILE 010208 5 off With interlocked opposing contacts 11DDILE 049824 5 off – 04DILE 010256 5 off With interlocked opposing contacts 13DILE 002397 5 off With interlocked opposing contacts 22DILE 010288 5 off With interlocked opposing contacts 31DILE 048912 5 off With interlocked opposing contacts 40DILE 010304 5 off With interlocked opposing contacts 22DDILE 049823 5 off – 22 34 21 31 43 53 Price See price list Std. pack 22 32 44 54 DILEM-10(-G)(…) DILEM-01(-G)(…) DILEM-4(-G)(…) DILER40(-G) DILER31(-G) DILER22 DILEEM-10(-G)(…) DILEEM-01(-G)(…) DILEM12-10(-G)(…) DILEM12-01(-G)(…) 51 61 52 62 53 61 54 62 53 63 54 64 57 65 58 66 51 61 71 81 52 62 72 82 53 61 71 81 54 62 72 82 53 61 71 83 54 62 72 84 53 61 73 83 54 62 74 84 53 63 73 83 Notes The following applies to ...DILEM auxiliary contacts: • Contacts to EN 50012 The following applies to ...DILE auxiliary contacts: • Contacts to EN 50005 Contacts according to EN50012 are to be prefered. Type E combinations compy with EN 50011 and are to be given preference. No interlocked opposing contacts in NO earlymakes and NC late-breaks. 54 64 74 84 57 65 71 83 58 66 72 84 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 7 1.1 Mini contactor relays Accessories 1 VGDILE..., RCDILE..., MVDILE, BT480, P1DILEM Actuating voltage Us Circuit symbol For use with Part no. Article no. DILE... VGDILE48 010320 VGDILE250 010336 VGDILE415 010463 Price See price list Std. pack Information relevant for export to North America 10 off Product Standards V AC Suppressor circuits Varistor suppressor 24 - 48 AC A1 110 - 250 AC A2 380 - 415 AC 10 off 10 off UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 3211-03 UL Listed, CSA certified RC-Suppressor 24 - 48 AC A1 DILE... 110 - 250 AC A2 Notes 10 off RCDILE48 044264 RCDILE250 046320 Product Standards 10 off UL File No. UL CCN CSA File No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR2 UL Recognized For AC operated contactors 50 - 60 Hz. DC operated contactor relays have an integrated suppressor. Note drop-out delay. VGDILE..., RCDILE..., MVDILE, BT480, P1DILEM For use with Part no. Article no. Price See price list Std. pack Information relevant for export to North America V0DILE 026634 50 off UL/CSA certification not required MVDILE 010113 5 off Product Standards Mechanical interlocks For mechanical connection of contactor and timing relays in combinations. 0 mm distance between contactors. DILE… DILET… Mechanical interlock For contactors with the same or different magnet system. 0 mm distance between contactors. Mechanical lifespan 2.5 x 106 operations. Additional auxiliary contact modules possible. – DILE… UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR2 012528 3211-07 UL Recognized, CSA certified Paralleling link For parallel connection of contacts – DILE… DILE… BT480 1) 052785 100 off Consisting of two four-pole paralleling links. DILEEM DILEM12 DILEM Notes 1) 2) 8 P1DILEM 2) 019095 5 off Not protected against accidental contact as specified in VDE 0106 Part 100. 4th pole can be broken off 4 pole: Ith = 60 A open 3 pole: Ith = 50 A open AC-1 current carrying capacity of the open contactor increases by a factor of 2.5 Protected against accidental contact in accordance with VDE 0106 Part 100 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 3211-07 UL Listed, CSA certified Mini contactor relays Accessories 1.1 HDILE, ...DILEM, MVS Contact sequence 1 For use with Part no. Article no. Price See price list Std. pack Information relevant for export to North America HDILE 010482 1 off UL/CSA certification not required S1DILEM 1) 220218 20 off MVS-WB-EM 2) 220209 1 off Sealable shrouds Transparent Snap-fitting on contactor. Can be used with open installation or on service distribution board. Protection type: IP40 front Can be drilled to accommodate timing relay setting dials. DILE… DILET… Start-point bridge DILEEM DILEM12 DILEM Reversing starter wiring kit Main current wiring for reversing combinations DILEEM (+MVDILEM) DILEM12 (+MVDILEM) DILEM (+MVDILEM) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV7 012528 3211-06 UL Listed, CSA certified Star-delta wiring kit Main current wiring for star-delta combination incl. star-point bridge DILE(E)M (+MVDILEM) DILE(E)M12 (+MVDILEM) DILE(E)M star contactor MVS-SB-EM 3) 220213 1 off Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Notes IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV7 012528 3211-06 UL Listed, CSA certified 1) Protected against accidental contact in accordance with VDE 0106 Part 100 The following control cables are integrated in addition to electrical interlock: • Q11: A1 -Q12: 21 • Q11: 21 - Q12: A1 • Q11: A2 - Q12: A2 For use with overload relay separate mounting. 3) The following control cables are integrated in addition to electrical interlock: • Q13: A1 -Q15: 21 • Q13: 21 - Q15: A1 • Q13: A2 - Q15: A2 For use with overload relay separate mounting. 2) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 9 1.1 Contactor relays Basic devices DILA Basic devices with positively driven contacts 1 Contact N/O = normally open contact Rated operational current NC = normally closed contact A C - 15 220 V 230 V 240 V Ie Screw terminals 4 N/O – 3 N/O 1 NC 380 V 400 V 415 V Ie A A 4 4 Distinctive number Can be combined with auxiliary contact 16 40E DILA-XHI(V)… A1 13 23 33 43 16 31E DILA-XHI(V)… A1 13 21 33 43 Conventional thermal current I th Circuit symbol A A2 14 24 34 44 4 4 A2 14 22 34 44 2 N/O 2 NC 4 4 16 22E DILA-XHI(V)… A1 13 21 31 43 A2 14 22 32 44 Spring-loaded terminals 4 N/O – 4 4 16 40E DILA-XHIC(V)… A1 13 23 33 43 3 N/O 1 NC 4 4 16 31E DILA-XHIC(V)… A1 13 21 33 43 A2 14 24 34 44 A2 14 22 34 44 2 N/O 2 NC 4 4 16 22E DILA-XHIC(V)… A1 13 21 31 43 A2 14 22 32 44 Notes 10 Contact numbers to EN 50011 Coil terminal markings to EN 50005 The following applies to DC-operated contactors: • Integrated suppressor circuit AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 3211-03 UL Listed, CSA certified Contactor relays Basic devices 1.1 1 AC operation Part no. Article no. DILA-40(230V50Hz) 276329 DC operation Price See price list Std. pack 1 off Circuit symbol A1 13 23 33 43 Part no. Article no. Price See price list DILA-40(24VDC) 276344 Std. pack Notes 1 off With screw terminals: A2 14 24 34 44 DILA-31(230V50Hz) 276364 1 off DILA-22(230V50Hz) 276399 1 off A1 13 21 33 43 A2 14 22 34 44 A1 13 21 31 43 A2 14 22 32 44 DILA-31(24VDC) 276379 DILA-22(24VDC) 276414 2 1 Accessories 1 Suppressor 2 Auxiliary contact modules Further actuating voltages DILAC-40(230V50Hz) 276441 1 off A1 13 23 33 43 DILAC-40(24VDC) 276456 1 off Page 50 36 68 With spring-loaded terminals: A2 14 24 34 44 DILAC-31(230V50Hz) 276473 1 off DILAC-22(230V50Hz) 276505 1 off A1 13 21 33 43 A2 14 22 34 44 A1 13 21 31 43 A2 14 22 32 44 DILAC-31(24VDC) 276488 DILAC-22(24VDC) 276520 2 1 Accessories 1 Suppressor 2 Auxiliary contact modules Further actuating voltages AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Page 50 36 68 11 1.1 Contactor relays Auxiliary contact modules DILA...XHI... DILA auxiliary contact modules 1 Screw terminals 2 pole Contact Rated operational current Conventional thermal current N/O = normally open contact S F = NO early-make NC = normally closed contact Ö S = NC late-break AC-15 220 V 230 V 240 V Ie A 380 V 400 V 415 V Ie A I th Circuit symbol A – – 2 NC – 4 4 16 1 N/O – 1 NC – 4 4 16 2 N/O – – – 4 4 16 – 1 SF 51 61 52 62 53 61 54 62 53 63 54 64 – 1 ÖS 4 4 16 57 65 58 66 4 pole Screw terminals – – 4 NC – 4 4 16 51 61 71 81 52 62 72 82 1 N/O – 3 NC – 4 4 16 2 N/O – 2 NC – 4 4 16 53 61 71 83 3 N/O – 1 NC – 4 4 16 53 61 73 83 4 N/O – – – 4 4 16 53 63 73 83 1 N/O 1 SF 1 NC 1 ÖS 4 4 16 – – 2 NC – 4 4 16 1 N/O – 1 NC – 4 4 16 2 N/O – – – 4 4 16 – 1 SF – 1 ÖS 4 4 16 53 61 71 81 54 62 72 82 54 62 72 84 54 62 74 84 54 64 74 84 57 65 71 83 58 66 72 Spring-loaded terminals 2 pole 84 51 61 52 62 53 61 54 62 53 63 54 64 57 65 58 66 Spring-loaded terminals 4 pole – – 4 NC – 4 4 16 51 61 71 81 52 62 72 82 1 N/O – 3 NC – 4 4 16 53 61 71 81 54 62 72 82 2 N/O – 2 NC – 4 4 16 53 61 71 83 54 62 72 84 3 N/O – 1 NC – 4 4 16 53 61 73 83 4 N/O – – – 4 4 16 53 63 73 83 1 N/O 1 SF 1 NC 1 ÖS 4 4 16 54 62 74 84 54 64 74 84 57 65 71 83 58 66 72 Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification 12 IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 3211-03 UL Listed, CSA certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 84 Contactor relays Auxiliary contact modules 1.1 1 Distinctive number/type of combinations DILA(C)-40 DILA(C)-31 Part no. Article no. DILA(C)-22 42E 33 24 51E 42 60E Price See price list Std. pack Description Notes DILA-XHI02 276420 5 off With interlocked opposing contacts 33 DILA-XHI11 276421 5 off With interlocked opposing contacts 51 42 DILA-XHI20 276422 5 off With interlocked opposing contacts Type E combinations comply with EN 50011 and must be given preference. The other combinations comply with EN 50005 The DC operated contactor DILA(C)-22 must only be combined with 2 pole auxiliary contacts. 51 42 33 DILA-XHIV11 276423 5 off – 44E 35 26 DILA-XHI04 276424 5 off With interlocked opposing contacts 53E 44 35 DILA-XHI13 276425 5 off With interlocked opposing contacts 62E 53 44 DILA-XHI22 276426 5 off With interlocked opposing contacts 71E 62 53 DILA-XHI31 276427 5 off With interlocked opposing contacts 80E 71 62 DILA-XHI40 276428 5 off With interlocked opposing contacts 62 53 44 DILA-XHIV22 276429 5 off – 42E 33 24 DILA-XHIC02 276526 5 off With interlocked opposing contacts 51E 42 33 DILA-XHIC11 276527 5 off With interlocked opposing contacts 60E 51 42 DILA-XHIC20 276528 5 off With interlocked opposing contacts 51 42 33 DILA-XHICV11 276529 5 off – 44E 35 26 DILA-XHIC04 276530 5 off With interlocked opposing contacts 53E 44 35 DILA-XHIC13 276531 5 off With interlocked opposing contacts 62E 53 44 DILA-XHIC22 276532 5 off With interlocked opposing contacts 71E 62 53 DILA-XHIC31 276533 5 off With interlocked opposing contacts 80E 71 62 DILA-XHIC40 276534 5 off With interlocked opposing contacts 62 53 44 DILA-XHICV22 276535 5 off – Type E combinations comply with EN 50011 and must be given preference. The other combinations comply with EN 50005 The DC operated contactor DILA(C)-22 must only be combined with 2 pole auxiliary contacts. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 13 1.1 1 Contactors Technical overview DILM, DILE(E)M, DILMP Contactors 3 pole DIL Basic devices Page EEM Complete units Page Rated-operational voltage AC-3 Rated operational power for 3-phase motors 50 –60 Hz 220 V – 230 V 380 V – 400 V 440 V 500 V 660 V/690 V 1000 V EM EM12 M7 4 M9 M12 M15 M17 18 – Page 24 M25 M32 M38 M40 M50 M65 M80 M95 18 20 46 Page 24 Page 26 Page 26 – M115 M150 M170 kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW 1.5 3 3.3 3 3 – 2.2 4 4.6 4 4 – 3 5.5 5.5 5.5 4 – 2.2 3 4.5 3.5 3.5 – 2.5 4 5.5 4.5 4.5 – 3.5 5.5 7.5 7 6.5 – 4 7.5 8.4 7.5 7 – 5 7.5 10.5 12 11 – 7.5 11 15.5 17.5 14 – 10 15 20 23 17 – 11 18.5 21 24 21 – 12.5 18.5 25 28 23 – 15.5 22 32 36 30 – 20 30 41 47 35 – 25 37 51 58 63 – 30 45 60 70 75 – 37 55 75 85 90 – 48 75 95 110 96 – 52 90 105 120 140 – AC-4 Rated operational power for 3-phase motors 50 –60 Hz 220 V – 230 V 1.1 380 V – 400 V 2.2 440 V 2.4 Increase in life span for DILM7 – DILM150 to 200000 operations 1.5 3 3.3 1.5 3 3.3 1 2.2 2.4 1.5 2.5 3 2 3 3.6 2 3 3.6 2.5 4.5 5.5 3.5 6 7 4 7 8 4 7 8 5 9 10 6 10 12 7 12 14 12 20 25 16 26 32 17 28 35 20 33 41 20 33 41 500 V 2.2 3 3 660 V/690 V 2.2 3 3 1000 V – – – AC-1 Rated operational power under resistive load, 40 °C 2.5 2.9 – 2.8 3.6 – 3.5 4.4 – 3.5 4.4 – 6 6.5 – 8 8.5 – 9 10 – 9 10 – 11 12 – 13 14 – 16 17 – 29 26 – 36 35 – 40 43 – 47 48 – 47 48 – 220 V – 230 V 380 V – 400 V 400 V 8 13 15 8 13 15 8 13 15 8 14 16 8 14 16 8 14 16 8 14 16 15 26 30 17 29 34 17 29 34 17 29 34 22 39 45 30 53 58 37 65 71 42 72 80 49 85 94 61 105 116 72 125 138 85 150 170 500 V 660 V/690 V 1000 V Conventional thermal Current I th = I e open at 40 °C 18 23 – 18 23 – 18 23 – 19 25 – 19 25 – 19 25 – 19 25 – 34 45 – 38 51 – 38 51 – 38 51 – 51 68 – 66 91 – 81 111 – 90 125 – 107 148 – 132 182 – 156 216 – 194 268 – A A A A A A A A A A A A A A A A A A A 22 22 22 22 22 22 22 40 45 45 45 60 80 98 110 130 160 190 225 DILM, DILE(E)M, DILMP Contactors 4 pole Rated operational voltage DIL Page AC-1 Conventional free air thermal current Ith = Ie open, at 40 °C up to 690 V 14 EM4 4 MP20 Page 34 MP32 Page 34 A A A 22 22 32 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors 1 DILM, DILH, DILMP Contactors 3 pole M185A M225A – – Page 30 M250A – M300A M400 – – Page 30 M500 – M580 M650 – – Page 30 M750 M820 – – Page 30 M1000 – M1600 M1400 – – Page 32 H2000 – H2200 – H2600 – kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW 55 90 115 132 70 110 142 160 75 132 157 180 90 160 190 215 125 200 255 290 155 250 345 360 185 315 370 420 205 355 420 470 240 400 480 550 260 450 525 600 315 560 650 730 500 900 1000 1180 – – – – – – – – – – – – – – – – 175 108 215 108 240 108 286 132 344 132 344 132 560 600 630 600 720 800 750 800 1000 1000 1600 1770 – – – – – – – – 41 75 85 51 90 102 62 110 125 75 132 140 92 160 186 112 200 229 143 250 290 161 280 326 181 315 367 209 355 418 260 450 520 430 750 830 – – – – – – – – – – – – 96 127 108 116 155 108 143 189 108 172 229 132 214 283 132 260 344 132 330 440 509 370 494 509 417 556 678 474 633 678 590 780 1000 940 1300 1650 – – – – – – – – – – – – 121 210 243 139 241 279 155 268 310 177 306 354 221 382 443 310 535 620 354 612 709 376 650 753 398 689 797 443 766 886 443 766 886 717 1247 1371 620 1071 1240 886 1531 1773 1075 1870 2058 1269 2207 2427 277 365 554 317 419 635 352 465 705 403 532 806 503 664 1007 705 930 1410 806 1064 1612 856 1130 1712 906 1196 1813 1007 1330 2015 1007 1330 2015 1558 2151 2420 1410 1861 2417 2015 2660 3223 2338 3227 4676 2758 3806 5516 A A A A A A A A A A A A A A A A 337 356 400 430 612 857 980 1041 1102 1225 1225 2200 1714 2450 2700 3185 DILM, DILE(E)M, DILMP Contactors 4 pole MP45 Page 34 MP63 Page 34 MP80 MP125 Page 34 MP160 MP200 A 45 A 63 A 80 A 125 A 160 A 200 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 15 1.1 1 Contactors System overview 8 6 DILM7...DILM170 6 1 1 Contactors up to 90 kW (AC-3/400V) 1 3 pole Page 18 4 pole Page 34 Suppressor circuits 2 Page 50 2 T1 4 T2 6 T3 Overload relays 3 Chapter 1.2 (Page 8) 7 Auxiliary contact modules 9 2 57 4 Page 36 3 NO Auxiliary contact modules 58 5 Range (s) 1 65 10 Page 36 100 NC 66 Time Auxiliary contact modules 5 5 6 Page 39 4 10 Motor feeder plug 6 6 7 Page 58 PE module with contact plate 8 Page 58 1 1 Motor suppressor module 9 Page 59 SmartWire-DT® contactor module Page 58 3 3 2 3 4 16 5 5 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 10 Contactors 1.1 1 1 5 2 4 3 DILM185... DILH2600 Contactors 90 – 900 kW (AC-3/400 V) Comfort series Page 30 Standard range 90–250kW Page 28 1 1 Mechanical interlock Page 52 2 Terminal shroud Page 61 4 Overload relays 3 Auxiliary contact modules 5 Chapter 1.2 (Page 12) Page 39 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 17 1.1 Contactors Basic devices up to 170 A DILM Basic device 1 Screw terminals 3 pole Rated operational current Max. motor rating for three-phase motors 50 - 60 Hz AC-3 AC-3 380 V 400 V 220 V 230 V AC-4 380 V 400 V 660 V 690 V 220 V 230 V 380 V 400 V 660 V 690 V Open Circuit symbol N/O = normally open contact NC = normally closed contact Ie P P P P P P Ith = Ie kW kW kW kW kW kW A 7 2.2 3 3.5 1 2.2 2.9 20 1 N/O – 7 2.2 3 3.5 1 2.2 2.9 20 – 1 NC 3 5 13 A2 2 4 6 14 A1 1 3 5 A2 2 4 6 22 A1 1 3 5 13 A1 1 21 9 2.5 4 4.5 1.5 2.5 3.6 20 1 N/O – A2 2 4 6 14 9 2.5 4 4.5 1.5 2.5 3.6 20 – 1 NC A1 1 5 A2 2 4 6 22 12 3.5 5.5 6.5 2 3 4.4 20 1 N/O – A1 1 3 5 13 A2 2 4 6 14 12 3.5 5.5 6.5 2 3 4.4 20 – 1 NC A1 1 5 A2 2 4 6 22 15.5 4 7.5 7 2 3 4.4 20 1 N/O – A1 1 3 5 13 A2 2 4 6 14 A1 1 3 5 A2 2 4 6 22 A1 1 18 18 25 4 5 5 7.5 7.5 7.5 7.5 11 7 11 11 14 2 2.5 2.5 3.5 3 4.5 4.5 6 4.4 6.5 6.5 8.5 20 35 35 40 – 1 N/O – 1 N/O 1 NC – 1 NC – 3 3 21 21 21 3 5 13 A2 2 4 6 14 A1 1 3 5 A2 2 4 6 22 A1 1 3 5 13 A2 2 4 6 14 5 21 25 7.5 11 14 3.5 6 8.5 40 – 1 NC A1 1 A2 2 4 6 22 32 10 15 17 4 7 10 40 1 N/O – A1 1 3 5 13 A2 2 4 6 14 5 3 21 32 10 15 17 4 7 10 40 – 1 NC A1 1 A2 2 4 6 22 38 11 18.5 21 4 7 10 40 1 N/O – A1 1 3 5 13 A2 2 4 6 14 A1 1 3 5 A2 2 4 6 22 38 11 18.5 21 4 7 10 40 Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification See also 18 Contact configuration A 15.5 Screw terminals 3 pole Conventional thermal current I th = Ie AC-1 at 60 °C IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 2411-03, 3211-04 UL Listed, CSA certified Page 80 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical – 1 NC 3 21 21 Contactors Basic devices up to 170 A 1.1 1 AC operation DC operation Can be combined with auxiliary contact Part no. Article no. DILM32-XHI.. DILA-XHI(V).. DILM7-10(230V50Hz) 276550 DILM7-10(24VDC) 276565 DILA-XHI(V).. DILM7-01(230V50Hz) 276585 DILM7-01(24VDC) 276600 DILM32-XHI.. DILA-XHI(V).. DILM9-10(230V50Hz) 276690 DILM9-10(24VDC) 276705 DILA-XHI(V).. DILM9-01(230V50Hz) 276725 DILM9-01(24VDC) 276740 DILM32-XHI.. DILA-XHI(V).. DILM12-10(230V50Hz) 276830 DILM12-10(24VDC) 276845 DILA-XHI(V).. DILM12-01(230V50Hz) 276865 DILM12-01(24VDC) 276880 DILM32-XHI.. DILA-XHI(V).. DILM15-10(230V50Hz) 1) 290058 DILM15-10(24VDC)1) 290073 DILA-XHI(V).. DILM15-01(230V50Hz) 1) 290093 DILM15-01(24VDC)1) 290108 DILM32-XHI.. DILA-XHI(V).. DILM32-XHI11-S DILM17-10(230V50Hz) 277004 DILM17-10(RDC24) 277018 DILA-XHI(V).. DILM32-XHI11-S DILM17-01(230V50Hz) 277036 DILM17-01(RDC24) 277050 DILM32-XHI.. DILA-XHI(V).. DILM32-XHI11-S DILA-XHI(V).. DILM32-XHI11-S DILM25-10(230V50Hz) 277132 DILM25-10(RDC24) 277146 DILM25-01(230V50Hz) 277164 DILM25-01(RDC24) 277178 DILM32-10(230V50Hz) 277260 DILM32-10(RDC24) 277274 DILM32-01(230V50Hz) 277292 DILM32-01(RDC24) 277306 DILM38-10(230V50Hz) 1) 112428 DILM38-10(RDC24)1) 112442 DILM38-01(230V50Hz) 1) 112456 DILM38-01(RDC24)1) 112470 DILM32-XHI.. DILA-XHI(V).. DILM32-XHI11-S DILA-XHI(V).. DILM32-XHI11-S DILM32-XHI.. DILA-XHI(V).. DILM32-XHI11-S DILA-XHI(V).. DILM32-XHI11-S Price See price list Part no. Article no. Price See price list Std. pack Notes 1 off Contacts to EN 50 012. For all DC operated contactors DILM7 - DILM15 the following applies: • Integrated varistor-suppressor circuit. For DC operated contactors DILM17 - DILM170 the following applies: • Integrated suppressor circuit in actuating electronics For AC operated contactors DILM115 - DILM170 the following applies: • Integrated suppressor circuit in actuating electronics For DILM7-01 – DILM38-01 the following applies: • With mirror contact. 1) Electrical lifespan 87 3 2 Accessories 1 Overload relay 2 Suppressor 3 Auxiliary contact module Further actuating voltages Accessories 1 Page Chapter 1.2 50 36 69 52 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 19 1.1 Contactors Basic devices up to 170 A DILM Basic device 1 Screw terminals 3 pole Rated operational current Max. motor rating for three-phase motors 50 - 60 Hz AC-3 AC-3 380 V 400 V 220 V 230 V AC-4 380 V 400 V 660 V 690 V 220 V 230 V 380 V 400 V 660 V 690 V Open Ie P P P P P P Ith = Ie A kW kW kW kW kW kW A 40 12.5 18.5 23 5 9 12 50 50 65 72 Screw terminals 3 pole Conventional thermal current I th = Ie AC-1 at 60 °C 80 95 115 150 170 15.5 20 25 25 30 37 48 52 22 30 37 37 45 55 75 90 30 35 35 63 75 90 96 140 6 7 7 12 16 17 20 20 10 12 12 20 26 28 33 33 14 17 17 26 35 43 48 48 65 80 80 90 110 130 160 185 Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification See also 20 IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 2411-03, 3211-04 UL Listed, CSA certified Page 80 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Contact configuration Circuit symbol N/O = normally open contact NC = normally closed contact – – – – – – – – – – – – – – – – – – A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 Contactors Basic devices up to 170 A 1.1 1 AC operation DC operation Can be combined with auxiliary contact Part no. Article no. Price See price list Part no. Article no. DILM150-XHI(V).. DILM1000XHI(V).. DILM150-XHI(V).. DILM1000XHI(V).. DILM150-XHI(V).. DILM1000XHI(V).. DILM150-XHI(V).. DILM1000XHI(V).. DILM150-XHI(V).. DILM1000XHI(V).. DILM40(230V50Hz) 277766 DILM40(RDC24) 277780 DILM50(230V50Hz) 277830 DILM50(RDC24) 277844 DILM65(230V50Hz) 277894 DILM65(RDC24) 277908 DILM72(230V50Hz) 1) 107670 DILM72(RDC24)1) 107671 DILM80(230V50Hz) 239402 DILM80(RDC24) 239416 DILM150-XHI(V).. DILM1000XHI(V).. DILM95(230V50Hz) 239480 DILM95(RDC24) 239510 DILM150-XHI(V).. DILM1000XHI(V).. DILM150-XHI(V).. DILM1000XHI(V).. DILM150-XHI(V).. DILM1000XHI(V).. DILM115(RAC240) 239548 DILM115(RDC24) 239555 DILM150(RAC240) 239588 DILM150(RDC24) 239591 DILM170(RAC240)1) 107013 DILM170(RDC24)1) 107016 Price See price list Std. pack Notes 1 off Contacts to EN 50012. For all DC operated contactors DILM7 - DILM15 the following applies: • Integrated varistor-suppressor circuit. For DC operated contactors DILM17 - DILM170 the following applies: • Integrated suppressor circuit in actuating electronics For AC operated contactors DILM115 - DILM170 the following applies: • Integrated suppressor circuit in actuating electronics For DILM7-01 – DILM38-01 the following applies: • With mirror contact. 1) Electrical lifespan 87 3 2 Accessories 1 Overload relay 2 Suppressor 3 Auxiliary contact module Further actuating voltages Accessories 1 Page Chapter 1.2 50 36 71 52 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 21 1.1 Contactors Basic devices up to 170 A DILM Basic device 1 Spring-loaded terminals 3 pole Rated operational current Max. motor rating for three-phase motors 50 - 60 Hz AC-3 380 V 400 V Ie A AC-3 220 V 230 V P kW 380 V 400 V P kW 660 V 690 V P kW AC-4 220 V 230 V P kW 380 V 400 V P kW 660 V 690 V P kW I th = Ie A 7 2.2 3 3.5 1 2.2 2.9 20 7 9 9 12 Spring-loaded terminals on auxiliary and control circuit terminals 3 pole 2.2 2.5 2.5 3.5 3 4 4 5.5 3.5 4.5 4.5 6.5 1 1.5 1.5 2 Conventional thermal current Ith = Ie AC-1 at 60 °C 2.2 2.5 2.5 3 2.9 3.6 3.6 4.4 Open 20 20 20 20 Circuit symbol N/O = normally open contact NC = normally closed contact 1 N/O – 1 N/O – 1 N/O – 1 NC – 1 NC – 3 5 13 A2 2 4 6 14 A1 1 3 5 A2 2 4 6 22 A1 1 A1 1 21 3 5 13 A2 2 4 6 14 A1 1 3 5 A2 2 4 6 22 A1 1 21 3 5 13 A2 2 4 6 14 5 12 3.5 5.5 6.5 2 3 4.4 20 – 1 NC A1 1 A2 2 4 6 22 15.5 4 7.5 7 2 3 4.4 20 1 N/O – A1 1 3 5 13 A2 2 4 6 14 15.5 4 7.5 7 2 3 4.4 20 – 1 NC A1 1 5 A2 2 4 6 22 18 5 7.5 11 2.5 4.5 6.5 35 1 N/O – A1 1 3 5 13 A2 2 4 6 14 18 5 7.5 11 2.5 4.5 6.5 35 – 1 NC A1 1 3 5 A2 2 4 6 22 A1 1 25 25 7.5 7.5 11 11 14 14 3.5 3.5 6 6 8.5 8.5 40 40 1 N/O – – 1 NC 32 10 15 7 10 40 1 N/O – 32 10 15 7 10 40 – 1 NC 40 12.5 18.5 9 12 50 – – 50 15.5 22 10 14 65 – – 65 20 30 12 17 80 – – 80 25 37 63 12 20 26 90 – – 95 30 45 75 16 26 35 110 – – 115 37 55 90 17 28 43 130 – – 150 48 75 96 20 33 48 160 – – Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification See also 22 Contact configuration IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 2411-03, 3211-04 UL Listed, CSA certified Page 80 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 3 3 21 21 21 3 5 13 A2 2 4 6 14 A1 1 3 5 A2 2 4 6 22 A1 1 3 5 13 A2 2 4 6 14 A1 1 3 5 A2 2 4 6 22 A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 A1 1 3 5 A2 2 4 6 21 21 Contactors Basic devices up to 170 A 1.1 1 Can be combined with auxiliary contact AC operation Part no. Article no. DC operation Price See price list Part no. Article no. DILM32-XHIC.. DILA-XHIC(V).. DILMC7-10(230V50Hz) 277389 DILMC7-10(24VDC) 277404 DILA-XHIC(V).. DILMC7-01(230V50Hz) 277421 DILMC7-01(24VDC) 277436 DILM32-XHIC.. DILA-XHIC(V).. DILMC9-10(230V50Hz) 277453 DILMC9-10(24VDC) 277468 DILA-XHIC(V).. DILMC9-01(230V50Hz) 277485 DILMC9-01(24VDC) 277500 DILM32-XHIC.. DILA-XHIC(V).. DILMC12-10(230V50Hz) 277517 DILMC12-10(24VDC) 277532 DILA-XHIC(V).. DILMC12-01(230V50Hz) 277549 DILMC12-01(24VDC) 277564 DILM32-XHIC… DILA-XHIC(V)… DILMC15-10(230V50Hz) 293911 DILMC15-10(24VDC) 293926 DILA-XHIC(V)… DILMC15-01(230V50Hz) 293946 DILMC15-01(24VDC) 293961 DILM32-XHIC.. DILA-XHIC(V).. DILMC17-10(230V50Hz) 277581 DILMC17-10(RDC24) 277595 DILA-XHIC(V).. DILMC17-01(230V50Hz) 277611 DILMC17-01(RDC24) 277625 DILM32-XHIC.. DILA-XHIC(V).. DILMC25-10(230V50Hz) 277641 DILMC25-10(RDC24) 277655 DILA-XHIC(V).. DILMC25-01(230V50Hz) 277671 DILMC25-01(RDC24) 277685 DILM32-XHIC.. DILA-XHIC(V).. DILMC32-10(230V50Hz) 277701 DILMC32-10(RDC24) 277715 DILA-XHIC(V).. DILMC32-01(230V50Hz) 277731 DILMC32-01(RDC24) 277745 DILM150XHIC(V).. DILM1000-XHIC.. DILMC40(230V50Hz) 277965 DILMC40(RDC24) 277979 DILMC50(230V50Hz) 277995 DILMC50(RDC24) 278009 DILMC65(230V50Hz) 278025 DILMC65(RDC24) 278039 DILMC80(230V50Hz) 239618 DILMC80(RDC24) 239652 DILMC95(230V50Hz) 239685 DILMC95(RDC24) 239715 DILMC115(RAC240) 239736 DILMC115(RDC24) 239741 DILMC150(RAC240) 239751 DILMC150(RDC24) 239765 Std. pack Notes 1 off Contacts to EN 50 012. For DILMC7 – DILMC15 the following applies: • Auxiliary coil, and main current terminals with spring-loaded terminals. For DILMC17 – DILMC150 the following applies: • Auxiliary connections, coil connections with spring-loaded connection terminals. • Main current connections with screw terminals. For DC operated contactors DILMC7 - DILMC15 the following applies: • Integrated varistor-suppressor circuit. For DC operated contactors DILMC17 - DILMC150 the following applies: • Integrated suppressor circuit in actuating electronics For AC operated contactors DILMC115 - DILMC150 the following applies: • Integrated suppressor circuit in actuating electronics For DILMC7-01 – DILMC32-01 the following applies: • With mirror contact. Price See price list 3 2 1 Accessories 1 Overload relay 2 Suppressor 3 Auxiliary contact module Further actuating voltages Accessories AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Page Chapter 1.2 50 36 73 52 23 1.1 Contactors Complete device up to 170 A DILM complete device 1 Screw terminals Screw terminals Rated operational current AC-3 Max. motor rating for three-phase motors 50 - 60 Hz AC-3 AC-4 Conventional free air thermal current I th = Ie AC-1 at 60 °C 380 V 400 V 220 V 230 V 380 V 400 V 660 V 690 V 220 V 230 V 380 V 400 V 660 V 690 V Ie P P P P P P Open Ith = Ie A kW kW kW kW kW kW A 7 2.2 3 3.5 1 2.2 2.9 7 2.2 3 3.5 1 2.2 7 2.2 3 3.5 1 9 2.5 4 4.5 9 2.5 4 9 2.5 12 12 Circuit symbol Contact configuration: = Safety function by positive opening according to IEC/EN 60947-5-1 N/O = normally open contact NC = normally closed contact 20 2 N/O 1 NC 2.9 20 2 N/O 1 NC A2 2 4 6 14 22 32 44 2.2 2.9 20 3 N/O 2 NC A1 1 5 13 21 31 43 53 1.5 2.5 3.6 20 2 N/O 1 NC 4.5 1.5 2.5 3.6 20 2 N/O 1 NC A2 2 4 6 14 22 32 44 4 4.5 1.5 2.5 3.6 20 3 N/O 2 NC A1 1 5 13 21 31 43 53 3.5 5.5 6.5 2 3 4.4 20 2 N/O 1 NC 3.5 5.5 6.5 2 3 4.4 20 2 N/O 1 NC 12 3.5 5.5 6.5 2 3 4.4 20 3 N/O 2 NC 15.5 4 7.5 7 2 3 4.4 20 2 N/O 2 NC 18 18 18 25 25 5 5 5 7.5 7.5 7.5 7.5 7.5 11 11 11 11 11 14 14 2.5 2.5 2.5 3.5 3.5 4.5 4.5 4.5 6 6 6.5 6.5 6.5 8.5 8.5 35 35 35 40 40 2 N/O 2 N/O 3 N/O 2 N/O 2 N/O 1 NC 1 NC 2 NC 1 NC 1 NC A1 1 3 5 13 21 33 A2 2 4 6 14 22 34 A1 1 5 13 21 31 43 3 3 A2 2 4 6 14 22 32 44 54 A1 1 3 5 13 21 33 A2 2 4 6 14 22 34 A1 1 5 13 21 31 43 3 3 A2 2 4 6 14 22 32 44 54 A1 1 3 5 13 21 33 A2 2 4 6 14 22 34 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 A1 1 3 5 13 21 31 43 53 A2 2 4 6 14 22 32 44 54 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 A1 1 3 5 13 21 33 A2 2 4 6 14 22 34 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 A1 1 5 13 21 31 43 53 3 A2 2 4 6 14 22 32 44 54 A1 1 3 5 13 21 33 A2 2 4 6 14 22 34 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 A1 1 5 13 21 31 43 53 3 25 7.5 11 14 3.5 6 8.5 40 3 N/O 2 NC 32 10 15 17 4 7 10 40 2 N/O 1 NC 32 10 15 17 4 7 10 40 2 N/O 1 NC A2 2 4 6 14 22 32 44 32 10 15 17 4 7 10 40 3 N/O 2 NC A1 1 3 5 13 21 31 43 53 A2 2 4 6 14 22 32 44 54 Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification See also 24 Contact IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 2411-03, 3211-04 UL Listed, CSA certified Page 80 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical A2 2 4 6 14 22 32 44 54 A1 1 3 5 13 21 33 A2 2 4 6 14 22 34 A1 1 5 13 21 31 43 3 Contactors Complete device up to 170 A 1.1 1 AC operation Part no. Article no. DC operation Price See price list Part no. Article no. DILM7-21(230V50Hz) 276620 DILM7-21(24VDC) 276635 DILM7-22(230V50Hz) 106360 DILM7-22(24VDC) 106367 DILM7-32(230V50Hz) 276655 DILM7-32(24VDC) 276670 DILM9-21(230V50Hz) 276760 DILM9-21(24VDC) 276775 DILM9-22(230V50Hz) 106361 DILM9-22(24VDC) 106368 DILM9-32(230V50Hz) 276795 DILM9-32(24VDC) 276810 DILM12-21(230V50Hz) 276900 DILM12-21(24VDC) 276915 DILM12-22(230V50Hz) 106362 DILM12-22(24VDC) 106369 DILM12-32(230V50Hz) 276935 DILM12-32(24VDC) 276950 DILM15-22(230V50Hz) 106363 DILM15-22(24VDC) 106370 DILM17-21(230V50Hz) 277068 DILM17-21(RDC24) 277082 DILM17-22(230V50Hz) 106364 DILM17-22(RDC24) 106371 DILM17-32(230V50Hz) 277100 DILM17-32(RDC24) 277114 DILM25-21(230V50Hz) 277196 DILM25-21(RDC24) 277210 DILM25-22(230V50Hz) 106365 DILM25-22(RDC24) 106372 DILM25-32(230V50Hz) 277228 DILM25-32(RDC24) 277242 DILM32-21(230V50Hz) 277324 DILM32-21(RDC24) 277338 DILM32-22(230V50Hz) 106366 DILM32-22(RDC24) 106373 DILM32-32(230V50Hz) 277356 DILM32-32(RDC24) 277370 Price See price list Std. pack Notes 1 off 2 Accessories 1 Overload relay 2 Suppressor Accessories 1 Page Chapter 1.2 50 52 For all DC operated contactors DILM7 - DILM15 the following applies: • Integrated varistor suppressor circuit. For DC operated contactors DILM17 - DILM170 the following applies: • Integrated suppressor circuit in actuating electronics For AC operated contactors DILM115 - DILM170 the following applies: • Integrated suppressor circuit in actuating electronics For DILM7 - DILM150 the following applies: • With mirror contact. Contacts to EN 50012 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 25 1.1 Contactors Complete device up to 170 A DILM complete device 1 Screw terminals Screw terminals Rated operational current AC-3 Max. motor rating for three-phase motors 50 - 60 Hz AC-3 AC-4 380 V 400 V 220 V 230 V 380 V 400 V 660 V 690 V 220 V 230 V 380 V 400 V 660 V 690 V Ie P P P P P P Open Ith = Ie A kW kW kW kW kW kW A 40 12.5 18.5 23 5 9 12 50 15.5 22 30 6 10 65 20 30 35 7 12 80 25 37 63 12 20 Conventional free air thermal current Ith = Ie AC-1 at 60 °C Circuit symbol Contact configuration: = Safety function by positive opening according to IEC/EN 60947-5-1 N/O = normally open contact NC = normally closed contact 50 2 N/O 2 NC 14 65 2 N/O 2 NC 17 80 2 N/O 2 NC 26 90 2 N/O 2 NC 95 30 45 75 16 26 35 110 2 N/O 2 NC 115 37 55 90 17 28 43 130 2 N/O 2 NC 150 48 75 96 20 34 48 160 2 N/O 2 NC Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification See also 26 Contact IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 2411-03, 3211-04 UL Listed, CSA certified Page 80 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 Contactors Complete device up to 170 A 1.1 1 AC operation Part no. Article no. DC operation Price See price list Part no. Article no. DILM40-22(230V50Hz) 277798 DILM40-22(RDC24) 277812 DILM50-22(230V50Hz) 277862 DILM50-22(RDC24) 277876 DILM65-22(230V50Hz) 277926 DILM65-22(RDC24) 277940 DILM80-22(230V50Hz) 239449 DILM80-22(RDC24) 239463 DILM95-22(230V50Hz) 239527 DILM95-22(RDC24) 239541 DILM115-22(RAC240) 239578 DILM115-22(RDC24) 239581 DILM150-22(RAC240) 239598 DILM150-22(RDC24) 239601 Price See price list Std. pack Notes 1 off 2 Accessories 1 Overload relay 2 Suppressor Accessories 1 Page Chapter 1.2 50 52 For DC operated contactors DILM17 - DILM170 the following applies: • Integrated suppressor circuit in actuating electronics For AC operated contactors DILM115 - DILM170 the following applies: • Integrated suppressor circuit in actuating electronics For DILM7 - DILM150 the following applies: • With mirror contact. Contacts to EN 50012 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 27 1.1 Contactors DILM, DILH Standard devices greater than 150 A DILM...S/22... Standard device for currents greater than 150 A 1 DILM complete device Rated operational current Max. motor rating for three-phase motors 50 - 60 Hz AC-3 AC-3 380 V 400 V Ie 220 V 230 V P 380 V 400 V P 660 V 690 V P 220 V 230 V P 380 V 400 V P 660 V 690 V P Ith = Ie A kW kW kW kW kW kW A 250 75 132 240 62 110 189 400 300 DILM complete device 400 500 580 Notes 90 125 155 185 Conventional thermal current Ith = Ie AC-1 at 40 °C Open AC-4 160 200 250 315 195 344 344 344 75 92 112 112 132 160 160 283 200 344 200 344 430 612 857 920 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 1) Availability from August 2010. Previous DILM300/22, see Online Catalog at http://www.eaton.com/seasia-electrical For all contactors the following applies: • 660 V, 690 V or 1000 V: do not reverse directly • Integrated suppressor circuit in actuating electronics. DILM…-S contactors are actuated conventionally (+) L1 (–) N A2 A1 Stopping in the event of an emergency (emergency switching off) Accessories Auxiliary contact modules Enclosures Further actuating voltages 28 Circuit symbol AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Page 38 77 For use with DILM820-XHI… DILM820-XHI… DILM820-XHI… DILM820-XHI… DILM820-XHI… Contactors DILM, DILH Standard devices greater than 150 A 1.1 1 Part no. Article no. Price See price list Std. pack Information relevant for export to North America DILM250-S/22(220-240V50/60Hz) 274190 1 off Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification DILM300A-S/22(220-240V50/60Hz) 1) 139559 1 off Request filed for UL and CSA DILM400-S/22(220-240V50/60Hz) 274196 1 off DILM500-S/22(220-240V50/60Hz) 274199 1 off DILM570-S/22(220-240V50/60Hz) 110744 1 off Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification See also IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 1017510 3211-04 UL Listed, CSA certified IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 3211-04 UL Listed, CSA certified Additional approvals, Page 82 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 29 1.1 Contactors DILM, DILH Comfort devices greater than 150 A DILM, DILH 1 Rated operational current Contactors, comfort DILM Max. motor rating for three-phase motors 50 - 60 Hz AC-3 AC-3 380 V 400 V Ie A 220 V 230 V P 185 225 AC-4 660 V 690 V P 1000 V P 220 V 230 V P kW 380 V 400 V P kW kW kW 55 90 140 108 70 Conventional thermal current I th = Ie AC-1 at 60 °C Open 110 150 108 660 V 690 V P 1000 V I th = Ie P A kW 380 V 400 V P kW kW kW 41 75 102 77 51 110 90 77 275 315 250 75 132 195 108 62 110 160 109 330 300 90 160 195 132 75 132 160 109 350 400 500 580 125 155 185 200 250 315 344 344 560 132 132 600 92 112 143 160 200 250 283 344 440 132 132 509 500 700 800 650 205 355 630 600 161 280 494 509 850 750 240 400 720 800 181 315 556 678 900 820 260 450 750 800 209 355 633 678 1000 Circuit symbol A1 1 3 6 14 22 32 44 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 A1 1 5 13 21 31 43 3 A2 2 4 6 14 22 32 44 5 13 21 31 43 1000 315 560 1000 1100 260 450 780 1000 1000 A1 1 A2 2 4 6 14 22 32 44 1600 500 900 1600 1770 430 750 1300 1650 1800 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 Notes 3 1) Availability from August 2010. Previous DILM185/22 to DILM300/22, see Online Catalog at http://www.eaton.com/seasia-electrical For all contactors the following applies: • 660 V, 690 V or 1000 V: do not reverse directly • Integrated suppressor circuit in actuating electronics. When operating contactors DILM580 to DILM1600 behind a frequency inverter or mains with strong harmonic loads, the suppressor circuit on the load side must be removed. During high-voltage tests, the suppressor circuit on the load-side for DILM580 to DILH2600 contactors must be disconnected (see instructional leaflet). Control voltages RA250 110 V - 250 V AC/DC RAW250 230 V - 250 V AC/DC Accessories Auxiliary contact modules Suppressor circuits on load side Enclosures Further actuating voltages 30 5 13 21 31 43 A2 2 4 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Page 38 61 72 1.1 Contactors DILM, DILH Comfort devices greater than 150 A 1 Part no. Article no. Price See price list DILM185A/22(RAC240)1) 139537 Std. pack Notes 1 off Conventional A1/A2 are attached to power supply as normal DILM225A/22(RAC240)1) 139547 DILM 185 A, DILM 225 A DILM250 to DILM1000, DILH1400 DILM1600 to DILH 2600 (+) L1 (–) N (+) L1 (–) N (+) L1 (–) N A2 A10 A2 A10 A2 A1 A11 A1 A11 A1 A3 TY A3 A4 TX A4 DILM250/22(RA250)2) 208201 DILM300A/22(RA250)1) 2) 139556 Directly from the PLC A 24 V output from the PLC can be directly connected to the terminals A4/ A24. (+) L1 (–) N (+) L1 (–) N DILM400/22(RA250)3) 208209 A10 A2 A11 A1 A3 A10 A2 A11 A1 TY A3 TX A4 A4 DILM500/22(RA250)3) 208213 24 V GND 24 V GND From a low-power command device Low-power actuating devices such as PCB relays, pilot devices or position switches can be directly connected to A10/ A11. DILM580/22(RA250)3) 208216 DILM650/22(RA250)3) 208219 DILM750/22(RA250)3) 208222 DILM820/22(RA250)3) 208225 (+) L1 (–) N (+) L1 (–) N A10 A2 A10 A2 A11 A1 A11 A1 A3 TY A3 A4 TX A4 Stopping in the event of an emergency (emergency switching off) Max. cable capacitance 6 nF DILM1000/22(RA250)3) 267214 DILM1600/22(RAW250)3) 106727 Information relevant for export to North America 1) NA Certification Request filed for UL and CSA 2) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 1017510 3211-04 UL Listed, CSA certified 3) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification See also IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 3211-04 UL Listed, CSA certified Additional approvals, Page 82 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 31 1.1 Contactors DILM, DILH Comfort devices greater than 150 A DILM, DILH 1 Conventional thermal current Ith = Ie AC-1 at 60 °C Open Circuit symbol Part no. Article no. Price See price list Std. pack Ith = Ie A DILH comfort devices AC-1 1400 2000 2200 2600 Notes A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 DILH1400/22(RAW250)1) 272441 1 off DILH2000/22(RAW250)1) 272442 1 off DILH2200/22(RAW250)1) 111793 1 off DILH2600/22(RAW250) 2) 125945 1 off For all contactors the following applies: • 660 V, 690 V or 1000 V: do not reverse directly • Integrated suppressor circuit in actuating electronics. When operating contactors DILM580 to DILM1600 behind a frequency inverter or mains with strong harmonic loads, the suppressor circuit on the load side must be removed. During high-voltage tests, the suppressor circuit on the load-side for DILM580 to DILH2600 contactors must be disconnected (see instructional leaflet). Control voltages RAW250 230 V - 250 V AC/DC Accessories Auxiliary contact modules Suppressor circuits on load side Enclosures 32 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Page 38 61 Contactors DILM, DILH Comfort devices greater than 150 A 1.1 1 Notes Conventional A1/A2 are attached to power supply as normal Directly from the PLC A 24 V output from the PLC can be directly connected to the terminals A4/A24. DILH1400 DILM1600 to DILH 2600 (+) L1 (–) N (+) L1 (–) N A10 A2 A10 A2 A11 A1 A11 A1 A3 TY A3 A4 TX A4 (+) L1 (–) N (+) L1 (–) N A10 A2 A11 A1 A3 A10 A2 A11 A1 TY A3 TX A4 A4 24 V GND 24 V GND From a low-power command device Low-power actuating devices such as PCB relays, pilot devices or position switches can be directly connected to A10/A11. (+) L1 (–) N (+) L1 (–) N A10 A2 A10 A2 A11 A1 A11 A1 A3 TY A3 A4 TX A4 Stopping in case of emergency (Emergency-stop) Max. cable capacitance 6 nF Information relevant for export to North America 1) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 3211-04 UL Listed, CSA certified 2) NA Certification Request filed for UL and CSA AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 33 1.1 Leistungsschütze Basic devices up to 200 A DILMP 4 pole 1 Rated operational current open Conventional thermal current I th = Ie AC-1 at 50 °C Open AC-1 40 °C 55 °C 70 °C A A A A 22 21 30 20 Circuit symbol For use with I th = I e Contactors up to 200 A 4 pole Notes 1) A1 1 3 5 7 A2 2 4 6 8 DILM1000-XHI…can only be fitted on the left of DILMP. Contacts to EN 50012. For DC operated contactors DILMP20 the following applies: • Integrated varistor suppressor circuit. For DC operated contactors DILMP32 - DILMP200 the following applies: • Integrated suppressor circuit in actuating electronics. For AC operated contactors DILMP125 - DILMP200 the following applies: • Integrated suppressor circuit in actuating electronics. For DILMP32-01 and DILMP45-01 the following applies: • With mirror contact. 34 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical DILM32-XHI(C)… DILA-XHI(V)(C)… Leistungsschütze Basic devices up to 200 A AC operation 1.1 1 DC operation Price See price list Part no. Article no. DILMP20(230V50Hz,240V60Hz) 276970 Std. pack Part no. Article no. 1 off DILMP20(24VDC) 276985 Price See price list Std. pack Notes 1 off 1 1 2 Accessories 1 Auxiliary contact module 2 Suppressor Further actuating voltages Accessories Page 36 50 74 52 Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification See also IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 2411-03, 3211-04 UL Listed, CSA certified Page 81 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 35 1.1 Contactors Auxiliary contact modules DILM, DILA Auxiliary contact modules 1 With interlocked opposing contacts, except ...XHI(C)V Terminal type Top mounting auxiliary contacts Screw terminals Pole Conventional thermal current Ith = Ie AC-1 at 60 °C Open Ith = Ie A Contact configuration Circuit symbol Screw terminals 2 pole 16 1 N/O 1 NC 2 pole 16 – 1 NC 21 33 22 34 21 31 4 pole 16 2 N/O 2 NC 21 31 43 53 4 pole 16 3 N/O 1 NC 21 33 43 53 22 32 44 54 22 34 44 54 Top mounting auxiliary contacts Springloaded terminals 2 pole 16 Part no. Article no. DILM(C)7-10… DILM(C)9-10… DILM(C)12-10… DILM(C)15-10… DILM(C)17-10… DILM(C)25-10… DILM(C)32-10… DILM38-…10 DILMP20… DILMP32-10… DILMP45-10… DILL… DILM32-XHI11 277376 5 off DILM32-XHI02 277375 5 off DILM32-XHI22 277377 5 off DILM32-XHI31 106112 5 off 1 N/O 1 NC 21 33 DILM32-XHIC11 277751 5 off DILM32-XHIC02 277750 5 off DILM32-XHIC22 277752 5 off DILA-XHI20 276422 5 off DILA-XHI11 276421 5 off DILA-XHI02 276420 5 off DILA-XHIV11 276423 5 off DILA-XHI40 276428 5 off DILA-XHI31 276427 5 off DILA-XHI22 276426 5 off DILA-XHI13 276425 5 off DILA-XHI04 276424 5 off DILA-XHIV22 276429 5 off 22 34 2 pole 16 – 2 NC 21 31 22 32 Top mounting auxiliary contacts Top mounting auxiliary contacts Springloaded terminals 4 pole Screw terminals 2 pole 16 2 N/O 2 NC 21 31 43 53 22 32 44 54 16 1 N/O – 53 63 54 64 2 pole 16 1 N/O 1 NC 53 61 54 62 51 61 2 pole 16 – 2 NC 2 pole 16 1 SF 1 ÖS 57 65 4 pole 16 4 N/O – 53 63 73 83 52 62 58 66 Top mounting auxiliary contacts Screw terminals DILM(C)9… DILM(C)9… DILM(C)12… DILM(C)15… DILM(C)17… DILM(C)25… DILM(C)32… DILM38… DILMP20… DILMP32… DILMP45… DILL… 54 64 74 84 4 pole 16 3 N/O 1 NC 53 61 73 83 54 62 74 84 4 pole 16 2 N/O 2 NC 53 61 71 83 54 62 72 84 4 pole 16 1 N/O 3 NC 53 61 71 81 54 62 72 82 4 pole 16 – 4 NC 51 61 71 81 52 62 72 82 4 pole 16 1 N/O 1 SF 1 NC 1 ÖS 57 65 71 83 58 66 72 Notes • Auxiliary NC usable as mirror contact according to IEC/EN 60947-4-1, Annex F • Interlocked opposing contacts according to IEC/EN 60947-5-1 Annex L, inside the auxiliary contact modules, also for the integrated auxiliary contacts of the DILM 7 - DILM32 36 Price See price list Std. pack N/O = normally open contact S F = N/O early-make NC = normally closed contact Ö S = NC late-break 22 32 Top mounting auxiliary contacts For use with AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 84 Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 3211-03 UL Listed, CSA certified 1.1 Contactors Auxiliary contact modules DILM, DILA Auxiliary contact modules 1 With interlocked opposing contacts, except ...XHI(C)V Terminal type Top mounting auxiliary contacts Springloaded terminals Conventional thermal current I th = I e AC-1 at 60 °C Open I th = I e A Contact configuration 2 pole 16 2 N/O – 2 pole 16 1 N/O 1 NC Pole Circuit symbol 53 63 54 64 53 61 2 pole 16 – 2 NC 2 pole 16 1 SF 1 ÖS 51 61 52 62 57 65 58 66 Screw terminals 2 pole 2 pole 16 16 Part no. Article no. DILM(C)7… DILM(C)9… DILM(C)12… DILM(C)15… DILM(C)17… DILM(C)25… DILM(C)32… DILM38… DILMP20… DILMP32… DILMP45… DILL… DILA-XHIC20 276528 5 off DILA-XHIC11 276527 5 off DILA-XHIC02 276526 5 off DILA-XHICV11 276529 5 off 2 N/O 1 N/O 2 NC 1 NC 53 63 71 81 DILA-XHIR221) 139580 54 64 72 82 5 off DILA-XHIR11 110140 5 off DILA-XHIC40 276534 5 off DILA-XHIC31 276533 5 off DILA-XHIC22 276532 5 off DILA-XHIC13 276531 5 off DILA-XHIC04 276530 5 off DILA-XHICV22 276535 5 off 53 61 54 62 Top mounting auxiliary contacts Springloaded terminals 4 pole 16 4 N/O – 53 63 73 83 54 64 74 84 4 pole 16 3 N/O 1 NC 53 61 73 83 54 62 74 84 4 pole 16 2 N/O 2 NC DILM(C)9… DILM(C)9… DILM(C)12… DILM(C)15… DILM(C)17… DILM(C)25… DILM(C)32… 53 61 71 83 54 62 72 84 4 pole 16 1 N/O 3 NC 53 61 71 81 54 62 72 82 4 pole 16 – 4 NC 4 pole 16 1 N/O 1 SF 1 NC 1 ÖS 51 61 71 81 52 62 72 82 57 65 71 83 58 66 72 Notes • Auxiliary NC usable as mirror contact according to IEC/EN 60947-4-1, Annex F • Interlocked opposing contacts according to IEC/EN 60947-5-1 Annex L, inside the auxiliary contact modules, also for the integrated auxiliary contacts of the DILM 7 - DILM32 1) Price See price list Std. pack N/O = normally open contact S F = N/O early-make NC = normally closed contact Ö S = NC late-break 54 62 Top mounting auxiliary contacts For use with 1 N/C + 1 N/O above microswitch for electronic applications 84 Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 3211-03 UL Listed, CSA certified 1) NA Certification Request filed for UL and CSA AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 37 1.1 Contactors Auxiliary contact modules DILM Auxiliary contact modules 1 With interlocked opposing contacts Top mounting auxiliary contacts Connection type Pole conventional thermal current Ith = Ie AC-1 at 60 °C Open Ith = Ie A Contact configuration N/O = normally open contact SF = N/O early make NC = normally closed contact ÖS = NC latebreak Screw terminals 2 pole 16 2 N/O – Circuit symbol 13 23 14 24 2 pole 16 1 N/O 1 NC 13 21 14 22 2 pole 16 1 N/O 1 NC 53 61 54 62 2 pole 16 – 2 NC 11 21 12 22 Top mounting auxiliary contacts Screw terminals 4 pole 16 4 N/O – 13 23 33 43 14 24 34 44 4 pole 16 3 N/O 1 NC For use with Part no. Article no. DILM40… DILM50… DILM65… DILM72… DILM80… DILM95… DILM115… DILM150… DILM170… DILMP63… DILMP80… DILMP125… DILMP160… DILMP200… 13 21 33 43 14 22 34 44 4 pole 16 2 N/O 2 NC 13 21 31 43 14 22 32 44 4 pole 16 2 N/O 2 NC 53 61 71 83 54 62 72 84 4 pole 16 1 N/O 3 NC 13 21 31 41 Price See price list Std. pack Notes DILM150-XHI20 277945 5 off DILM150-XHI11 277946 5 off DILM150-XHIA11 283463 5 off DILM150-XHI02 277947 5 off DILM150-XHI40 277948 5 off Interlocked opposing contacts according to IEC/EN 60947-5-1 Annex L, inside the auxiliary contact modules Auxiliary NC usable as mirror contact according to IEC/EN 60947-4-1, Annex F DILM150-XHI31 277949 5 off DILM150-XHI22 277950 5 off DILM150-XHIA22 283464 5 off DILM150-XHI13 277951 5 off DILM150-XHI04 277952 5 off DILM150-XHIV22 277953 5 off – DILA-XHIT20 101042 5 off DILA-XHIT11 101043 5 off DILA-XHIT02 101041 5 off DILA-XHIT22 101044 5 off Interlocked opposing contacts according to IEC/EN 60947-5-1 Annex L, inside the auxiliary contact modules Auxiliary NC usable as mirror contact according to IEC/EN 60947-4-1, Annex F 14 22 32 42 4 pole 16 – 4 NC 11 21 31 41 12 22 32 42 4 pole High version1) 2 pole Screw terminals 16 16 1 N/O 1 SF 1 NC 1 ÖS 2 N/O – 13 21 35 47 14 22 36 48 53 63 54 64 2 pole 16 1 N/O 1 NC 53 61 54 62 2 pole 16 – 2 NC DILM7… DILM9… DILM12… DILM15… DILL… 51 61 52 62 High version1) Screw terminals 4 pole 16 2 N/O 2 NC 53 61 71 83 54 62 72 84 Notes 1) Suitable for the combination with electrical wiringlinks in tool-less plug connection usable with: DILM12-XSL DILM12-XRL DILM12-XS1 PKZM0-XDM12 PKZM0-XRM12 PKZM0-XSM12 Information relevant for export to North America Product Standards 1 4 1 PKZM0 2 DILM7 - DILM15 3 DILA-XHIT 4 PKZM0-XDM12 38 2 3 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 3211-03 UL Listed, CSA certified 1.1 Contactors Auxiliary contact modules DILM, DILA Side-mounting auxiliary contacts 1 Connection type Pole conventional thermal current Ith = Ie AC-1 at 60 °C Open Ith = Ie A Contact configuration N/O = normally open contact SF = N/O early make NC = normally closed contact ÖS = NC latebreak Screw terminals 1 pole 10 1 N/O – 1 pole 10 – 1 NC Circuit symbol 53 54 61 62 Springloaded terminals 1 pole 10 1 N/O – 53 For use with Part no. Article no. DILM(C)7… DILM(C)9… DILM(C)12… DILM(C)15… DILMP20… DILA(C)… Std. pack Notes DILA-XHI10-S 115948 1 off 1) DILA-XHI01-S 115949 1 off DILA-XHIC10-S 115950 1 off DILA-XHIC01-S 115951 1 off DILM17… DILM25… DILM32… DILM38… DILM32-XHI11-S 101371 1 off Can only be left on the contactor. Cannot be combined with mechanical interlock DILM250 DILH2600 DILM820-XHI11-SI 208281 1 off 1) DILM820-XHI11-SA 208282 1 off DILM820-XHI11V-SI 208283 1 off DILM1000-XHI11-SI 278425 1 off DILM1000-XHIV11-SI 278426 1 off DILM1000-XHI11-SA 278427 1 off 54 1 pole 10 – 1 NC 61 62 Side-mounting auxiliary contacts Screw terminals 2 pole Side-mounting auxiliary contacts Screw terminals 2 pole 10 1 N/O 1 NC 2 pole 10 1 N/O 1 NC 47 21 43 22 31 48 25 36 47 26 35 84 61 72 83 62 71 54 44 53 26 35 18 25 32 17 48 14 83 13 62 36 1 NC 18 61 71 1 N/O 1 ÖS 17 43 10 1 SF 1 NC 54 22 84 10 1 N/O 1 ÖS 53 31 10 1 SF 14 21 72 2 pole 10 13 44 2 pole 2 pole Notes 53 61 1 NC 32 Screw terminals 1 N/O 54 62 2 pole Side-mounting auxiliary contacts 10 DILM40 DILM225A DILMP63 DILMP200 Price See price list Information relevant for export to North America 1) • Interlocked opposing contacts according to IEC/EN 60947-5-1 Annex L, inside the auxiliary contact module, also for the integrated auxiliary contacts of the DILM7 – DILM32 (not NO earlymake and NC late-break) • Auxiliary NC usable as mirror contact according to IEC/EN 609474-1, Annex F (no NC late-breaks) • No auxiliary contact is possible between 2 contactors with mechanical interlock. 2) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 3211-03,3211-04 UL Listed, CSA certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 39 1.1 1 Contactors Auxiliary contact modules Engineering DILM, DILH DILM1000XHI(V)11-SI DILM820XHI(V)11-SI DILM1000XHI(V)11-SA DILM820XHI(V)11-SA DILM150-XHI20 DILM150-XHI11 DILM150-XHI02 DILM150-XHI40 DILM150-XHI31 DILM150XHI(V)22 DILM150-XHI13 DILM150-XHI04 DILM150XHIA11 DILM150XHIA22 2x – – – – 2x – – – 1x – – 1x – – – 1x – 2x 2x – – – – – 1x 2x – – – – – – – – – – 1x – – – – – – 1x – – 1x 2x – – – – – 1x – – – 2x 2x – – – – – 2x 2x 2x 2x – – – – – – 2x – 1x – – – 1x – – – – – – – – – – – – – – DILH1400 ... DILH2600 – 2x – 2x – – – – Notes Side mounting auxiliary contacts DILM40 ... DILM72 DILM80 ... DILM170 DILM185A DILM222A DILM250 DILM1600 DILM1000-XHI(C)..-SI DILM1000-XHI(C).. + + + + + + DILM1000-XHI(C)..-SA DILM820-XHI(C)..-SI + + + + DILM820-XHI(C)..-SA DILM40 – DILM72 DILM250 – DILH2600 DILM80-DILM225A • • • • • 40 Interlocked opposing contacts according to IEC/EN 60947-5-1 Annex L, inside the auxiliary contact module (not N/O early close and N/C late open) Auxiliary contacts can be used as mirror contacts according to IEC/EN 60947-4-1, Annex F (not N/C late open) No auxiliary contact is possible between two contactors with mechanical interlock. 2 auxiliary contacts DILM820-XHI11-SI are already built into the contactors DILM250 to DILH2600/22. 2 DILM1000-XHI11-SI auxiliary contacts are already installed in DILM185A and DILH225A contactors. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Contactors Contactor for capacitors 1.1 Ordering 1 DILK Three-phase capacitors 50 – 60 Hz Open 230 V With series resistors Basic Units Notes 400 V Circuit symbol 525 V 690 V kvar kvar kvar kvar 7.5 12.5 16.7 20 11 20 25 33.3 15 25 33.3 40 20 33.3 40 55 25 50 65 85 Part no. Article no. A1 1 3 5 13 21 A2 2 4 6 14 22 3 5 13 A1 1 A2 2 4 6 14 Price See price list Std. pack DILK12-11(230V50Hz,240V60Hz) 293988 DILK20-11(230V50Hz,240V60Hz) 294010 1 off DILK25-11(230V50Hz,240V60Hz) 294032 DILK33-10(230V50Hz,240V60Hz) 294054 DILK50-10(230V50Hz,240V60Hz) 294076 1 off 1 off 1 off 1 off Weld-resistant for capacitors with inrush current peaks up to 180 x IN With group compensation multi-stage capacitor banks are connected to the mains as required. This can cause, transient currents of up to 180 x Ie to flow between the capacitors. The capacitors are pre-charged via the early-make auxiliary contacts and the fitted wire resistors, thereby reducing the inrush current. The main contacts then close after a time lag and carry the continuous current. The contactors for capacitors are weld-resistant with inrush current peaks up to 180 x le due to their special contacts. DILK… cannot be combined with other auxiliary contacts. For the switching of reactive-power compensation equipment please see Engineering notes on power factor correction page 33. L1 L2 L3 A1 1 3 5 A2 2 4 6 R11 R11 C1 R11 Accessories Enclosures Accessories Further actuating voltages Page 52 76 Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification See also IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 3211-04 UL Listed, CSA certified Further approvals Page 66 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 41 1.1 1 Contactors Contactors for power factor correction Engineering DILM, DILK Ordering data Part no. DILM7-…(…) DILM9-…(…) DILM12-…(…) DILM15-…(…) DILM17-…(…) DILM25-…(…) DILM32-…(…) DILM40(…) DILM50(…) DILM65(…) DILM80(…) DILM95(…) DILM115(…) DILM150(…) DILM185A(…) DILM300A(…) DILM580(…) DILM7-…(…) DILM9-…(…) DILM12-…(…) DILM15-…(…) DILM17-…(…) DILM25-…(…) DILM32-…(…) DILM40(…) DILM50(…) DILM65(…) DILM80(…) DILM95(…) DILM115(…) DILM150(…) DILM185A(…) DILM225A(…) DILM250(…) DILM300A(…) DILM400(…) DILM500(…) DILK12-…(…) DILK20-…(…) DILK25-…(…) DILK33-…(…) DILK50-…(…) DILM185A(…) DILM300A(…) DILM580(…) Notes 42 Page 18 18 18 18 18 18 18 20 20 20 20 20 20 20 30 30 30 18 18 18 18 18 18 18 20 20 20 20 20 20 20 30 30 30 30 30 30 41 41 41 41 41 30 30 30 Switching power 230 V 400 V 420 V 440 V kvar 525 V 690 V kvar kvar Individual compensation, open version 1.5 3 3.5 5 2 2.5 2.5 4 4.5 4.5 4.5 5.5 5.5 6 7 7 6.5 7 7.5 11 11.5 12.5 16 18 24 12 13.5 14.5 20.5 22 23.5 30.5 34 46 14.5 16 17 24.5 26 28 36.5 41 54.5 19 21 22.5 32 34.5 37 48 54 72 28 87 115 53 150 200 63.5 190 265 83.5 150 200 175 300 400 Group compensation, with choke, open version 300 4 5 7 8 7.5 10 12 14 5.5 5.5 7.5 10 10 18 12 12 20 16 16 28 10 12.5 15 20 25 30 35 50 20 25 30 40 50 60 70 95 23 25 30 40 50 70 80 100 30 32 40 48 57 90 104 125 55 115 115 152 80 100 110 130 150 175 190 225 200 230 260 290 260 300 340 390 160 280 370 220 390 500 Group compensation, without choke, open version 480 680 kvar 7.5 12.5 16.7 20 11 15 20 25 66 85 145 20 25 33.3 50 115 150 250 25 33.3 40 65 145 195 333 33.3 40 55 85 115 150 250 Use of the contactors DILM without series resistor for group compensation When using the contactors for group compensation in a system without chokes each capacitor must have a minimum induction of approx. 6 μH to limit the peak inrush current. This corresponds to an air-cored coil with 5 windings and a coil diameter of approximately Ø 140 mm. The conductor cross section must correspond to the rated operational current. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Ordering 1 44 Contactor combinations Star-delta combinations Star-delta combinations SDAINL Operating frequency: maximum 30 starts per hour Rated operational current AC-3 400 V Ie A Max. rated operational power for three-phase motors, 50 - 60 Hz AC-3 230 V 400 V 500 V 690 V P P P P kW kW kW kW Max. changeover time s Part no. Article no. 12 4 5.5 5.5 – < 30 SDAINLEM(230V50Hz) 051840 1 off 12 3 5.5 5.5 5.5 < 20 SDAINLM12(230V50Hz) 278286 1 off 12 3 5.5 5.5 5.5 < 20 SDAINLM12(400V50Hz) 101380 1 off 12 3 5.5 5.5 5.5 < 20 SDAINLM12(24VDC) 100416 1 off 16 4 7.5 7.5 7.5 < 20 SDAINLM16(230V50Hz) 278311 1 off 16 4 7.5 7.5 7.5 < 20 SDAINLM16(400V50Hz) 101381 1 off 16 4 7.5 7.5 7.5 < 20 SDAINLM16(24VDC) 100417 1 off 22 5.5 11 11 11 < 20 SDAINLM22(230V50Hz) 278336 1 off 22 5.5 11 11 11 < 20 SDAINLM22(400V50Hz) 101382 1 off 22 5.5 11 11 11 < 20 SDAINLM22(24VDC) 100418 1 off 30 7.5 15 18.5 18.5 < 20 SDAINLM30(230V50Hz) 278361 1 off 30 7.5 15 18.5 18.5 < 20 SDAINLM30(400V50Hz) 101383 1 off 30 7.5 15 18.5 18.5 < 20 SDAINLM30(RDC24) 100419 1 off 45 11 22 30 22 < 20 SDAINLM45(230V50Hz) 278386 1 off 45 11 22 30 22 < 20 SDAINLM45(400V50Hz) 101384 1 off 45 11 22 30 22 < 20 SDAINLM45(RDC24) 100420 1 off 55 15 30 37 30 < 20 SDAINLM55(230V50Hz) 278411 1 off 55 15 30 37 30 < 20 SDAINLM55(400V50Hz) 101385 1 off 55 15 30 37 30 < 20 SDAINLM55(RDC24) 100421 1 off 70 18.5 37 45 37 < 20 SDAINLM70(230V50Hz) 239895 1 off 70 18.5 37 45 37 < 20 SDAINLM70(400V50Hz) 101386 1 off 90 22 45 55 45 < 20 SDAINLM90(230V50Hz) 239937 1 off 115 30 55 75 55 < 20 SDAINLM115(230V50Hz) 239963 1 off 140 37 75 90 90 < 20 SDAINLM140(230V50Hz) 240009 1 off 165 45 90 110 132 < 20 SDAINLM165(230V50Hz) 240035 1 off 200 55 110 132 160 < 20 SDAINLM200(230V50Hz) 101010 1 off 260 75 132 160 160 < 20 SDAINLM260(230V50Hz) 101031 1 off AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Price See price list Std. pack 1.1 Contactor combinations Star-delta combinations I n d iv id u a l c o m p o n e n ts o f th e c o m b in a tio n S p a r e a u x ilia r y c o n ta c ts Q11 Notes Mains contactor Q11 Delta contactor Q15 Star contactor Q13 Timing relays K1 Part no. Part no. Part no. Part no. DILEM-10 + 22DILEM DILEM-01 DILEM-10 + 02DILEM DILET DILM7-10 + DILA-XHI20 DILM7-01 + DILA-XHI20 DILM7-01 + DILA-XHI20 ETR4-51 63 64 64 64 DILM7-10 + DILA-XHI20 DILM7-01 + DILA-XHI20 DILM7-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM7-10 + DILA-XHI20 DILM7-01 + DILA-XHI20 DILM7-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM9-10 + DILA-XHI20 DILM9-01 + DILA-XHI20 DILM7-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM9-10 + DILA-XHI20 DILM9-01 + DILA-XHI20 DILM7-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM9-10 + DILA-XHI20 DILM9-01 + DILA-XHI20 DILM7-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM12-10 + DILA-XHI20 DILM12-01 + DILA-XHI20 DILM7-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM12-10 + DILA-XHI20 DILM12-01 + DILA-XHI20 DILM7-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM12-10 + DILA-XHI20 DILM12-01 + DILA-XHI20 DILM7-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM17-10 + DILA-XHI20 DILM17-01 + DILA-XHI20 DILM17-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM17-10 + DILA-XHI20 DILM17-01 + DILA-XHI20 DILM17-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM17-10 + DILA-XHI20 DILM17-01 + DILA-XHI20 DILM17-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM25-10 + DILA-XHI20 DILM25-01 + DILA-XHI20 DILM17-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM25-10 + DILA-XHI20 DILM25-01 + DILA-XHI20 DILM17-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM25-10 + DILA-XHI20 DILM25-01 + DILA-XHI20 DILM17-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM32-10 + DILA-XHI20 DILM32-01 + DILA-XHI20 DILM25-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM32-10 + DILA-XHI20 DILM32-01 + DILA-XHI20 DILM25-01 + DILA-XHI20 ETR4-51 63 63 63 64 64 64 DILM32-10 + DILA-XHI20 DILM32-01 + DILA-XHI20 DILM25-01 + DILA-XHI20 ETR4-51 63 63 63 DILM40 + DILM150-XHI31 DILM40 + DILM150-XHI11 DILM40 + DILM150-XHI11 ETR4-51 DILM40 + DILM150-XHI31 DILM40 + DILM150-XHI11 DILM40 + DILM150-XHI11 ETR4-51 DILM50 + DILM150-XHI31 DILM50 + DILM150-XHI11 DILM40 + DILM150-XHI11 ETR4-51 DILM65 + DILM150-XHI31 DILM65 + DILM150-XHI11 DILM40 + DILM150-XHI11 ETR4-51 DILM80 + DILM150-XHI31 DILM80 + DILM150-XHI11 DILM50 + DILM150-XHI11 ETR4-51 DILM95 + DILM150-XHI31 DILM95 + DILM150-XHI11 DILM65 + DILM150-XHI11 ETR4-51 DILM115 + DILM150-XHI31 DILM115 + DILM150-XHI11 DILM80 + DILM150-XHI11 ETR4-51 DILM150 + DILM150-XHI31 DILM150 + DILM150-XHI11 DILM95 + DILM150-XHI11 ETR4-51 21 31 53 Q13 Q15 – – 22 32 54 63 64 21 33 63 64 1 Main circuit: Depending on the type of coordination required (i.e. Type “1” or Type “2”) it must be established whether the fuse protection and the input wiring for the mains contactor and delta contactor are to be common or separate. The following applies for SDAINLM 140 – SDAINLM 260: • On the mounting plate. Circuit diagrams, Star-delta combinations page 46 1 Accessories 1 Overload relay Accessories Page Chapter 1.2 52 64 – – – – – – – – – – – – – – – – 22 34 21 33 22 34 21 33 22 34 21 33 22 34 21 33 22 34 21 33 22 34 21 33 22 34 21 33 22 34 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 45 1.1 1 Contactor combinations Star-delta combinations Engineering SDAINL Circuit diagrams, Star-delta combinations SDAINLEM 21 L1L2 L3 0 22 F1 13 B 1 x In 14 Q11 I 14 13 44 14 Q11 1 3 5 2 4 6 1 3 Q15 A 0.58 x I n 5 Q13 2 4 6 1 3 43 5 13 16 2 4 6 Q15 A1 M1 M 3~ K1 V2 W2 U2 18 22 C 0.58 x I n U1 V1 W1 15 K1 Q11 Q13 A2 A1 Q11 A1 Q13 A2 N 22 Q13 21 A2 21 A1 Q15 A2 Y N SDAINLM12…SDAINLM55 L1L2 L3 21 0 S11 F1 22 Q11 B Q11 1 3 1 x In 5 1 3 Q15 2 4 6 I 5 Q13 2 4 6 13 13 14 14 Q11 1 3 5 54 54 54 53 53 53 Q13 2 4 6 K1 Q15 C 0.58 x I n U1 V1 W1 M1 M 3~ (–)N V2 W2 U2 21 A1 A1 Q11 K1 A2 K1 22 Q15 A 0.58 x I n 17 18 A2 N A2 28 22 Q13 21 A1 A1 Q13 17 Q15 A2 Y SDAINLM70…SDAINLM260 L1L2 L3 21 0 S11 F1 22 Q11 B Q11 1 3 5 2 4 6 1 x In 1 3 Q15 I 5 2 4 6 Q13 13 13 14 14 Q11 1 3 5 44 14 14 43 13 13 Q13 2 4 6 K1 Q15 C 0.58 x I n U1 V1 W1 M1 M 3~ A1 Q11 V2 W2 U2 (–)N A2 N K1 22 Q15 A 0.58 x I n 17 18 A2 Q13 A2 28 22 Q13 A1 A1 K1 21 17 21 A1 Q15 A2 Y Overload relay settings Starting A: I N x 0.58 15 s Motor protected in Y and - positions B: I N x 1 15 – 40 s Only partial motor protection in Y position C: I N x 0.58 > 40 s Motor not protected in Y position Timing relay set to approx. 10 s Main circuit: Depending on the type of coordination required (i.e. Type “1” or Type “2”) it must be established whether the fuse protection and the input wiring for the mains contactor and delta contactor are to be common or separate. 46 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactor combinations Star-delta combinations SDAINL Components for self-assembly of star-delta combinations 1 Individual components of the combination Maximum operational rating of AC motors 50 - 60 Hz AC-3 Changeover time1) 230 V 400 V 500 V 690 V 1000 V kW kW kW kW kW 90 160 200 250 132 110 200 250 315 160 132 250 315 400 160 300 355 200 355 250 up to 12 s up to 20 s up to 30 s Coil to EN 50005 Switching element to EN 50005 and EN 50012 Star Delta Mains contactor contactor contactor Q13 Q15 Q11 Part no. DIL Part no. DIL Part no. DIL Timing relay K1 Part no. M185A/22 ETR4-51 M185A/22 M115/22 M225A/22 M225A/22 M150/22 ETR4-51 200 M250/22 M250/22 M185A/22 ETR4-51 450 200 M300A/22 M300A/22 M185A/22 ETR4-51 450 560 220 M400/22 M400/22 M250/22 ETR4-51 450 560 600 220 M500/22 M500/22 M300A/22 ETR4-51 300 560 710 900 355 M580/22 M580/22 M400/22 ETR4-51 350 630 750 950 355 M650/22 M650/22 M400/22 ETR4-51 400 710 900 1200 1400 M750/22 M750/22 M580/22 ETR4-51 450 800 950 1300 1400 M820/22 M820/22 M580/22 ETR4-51 560 1000 1200 1700 1700 M1000/22 M1000/22 M650/22 ETR4-51 1) Notes – Spare auxiliary contacts – – 1 3 5 1 3 5 Q11 Q15 2 4 6 21 31 31 43 22 32 32 44 32 44 21 31 31 43 31 43 31 43 22 32 32 44 32 44 21 31 31 43 31 43 22 32 32 44 32 44 21 31 31 43 31 43 22 32 32 44 32 44 21 31 31 43 31 43 22 32 32 44 32 44 21 31 31 43 31 43 22 32 32 44 32 44 21 31 31 43 31 43 22 32 32 44 32 44 21 31 31 43 31 43 22 32 32 44 32 44 21 31 31 43 31 43 22 32 32 44 32 44 21 31 31 43 31 43 22 32 32 44 32 44 21 31 31 43 31 43 22 32 32 44 32 44 C 1 3 5 1 3 5 Q11 2 4 6 Q15 2 4 6 1 3 5 Q13 2 4 6 A 2 4 6 C 1 3 5 Q13 Q15 2 4 6 2 4 6 A U1 V1 W1 1 3 5 Q13 2 4 6 A 1 3 5 Q13 N o te s B 1 3 5 Q15 Longer changeover times please enquire Components for self-assembly Q11 Q11 2 4 6 C M1 3 V2 W2 U2 M1 Overload relay settings Timing relay set to approx. 10 s Starting IN A x 0.58 Motor protection in Y and 15 s positions Bx1 In Y position only limited motor protection 15 – 40 s C x 0.58 Motor not protected in Y position > 40 s Main circuit: Depending on the coordination type required (i.e. Type “1” or Type “2”) it must be established whether the fuse protection and the input wiring for the mains contactor and delta contactor are to be common or separate. Control circuit: If the combinations are to be used within the scope of IEC/EN 60 204 Part 1, VDE 0113 Part 1, then Point 9.1.1 regarding the supply of control circuits, must be observed. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 47 1.1 1 Contactor combinations Reversing combinations Ordering DIUL reversing combinations AC operation AC operation AC operation Rated operational current Max. motor rating for three-phase motors 50 - 60 Hz AC-3 400 V Ie A AC-3 220 V 230 V P kW 380 V 400 V P kW 660 V 690 V P kW AC-4 220 V 230 V P kW 380 V 400 V P kW 660 V 690 V P kW 9 2.2 4 4 1.5 3 3 DIULEM/21/MV(230V50Hz)1) 051849 1 Off 9 2.2 4 4 1.5 3 3 DIULEM/21/MV-G(24VDC) 2) 214655 1 Off 7 2.2 3 3.5 1 2.2 2.9 DIULM7/21(230V50Hz) 2) 278061 1 Off 7 2.2 3 3.5 1 2.2 2.9 DIULM7/21(24VDC)2) 107021 1 Off 9 2.5 4 4.5 1.5 2.5 3.6 DIULM9/21(230V50Hz) 2) 278086 1 Off 9 2.5 4 4.5 1.5 2.5 3.6 DIULM9/21(24VDC)2) 107022 1 Off 12 3.5 5.5 6.5 2 3 4.4 DIULM12/21(230V50Hz) 2) 278111 1 Off 12 3.5 5.5 6.5 2 3 4.4 DIULM12/21(24VDC)2) 107023 1 Off 18 5 7.5 11 2.5 4.5 6.5 DIULM17/21(230V50Hz) 2) 278136 1 Off 18 5 7.5 11 2.5 4.5 6.5 DIULM17/21(RDC24)2) 107024 1 Off 25 7.5 11 14 3.5 6 8.5 DIULM25/21(230V50Hz) 2) 278161 1 Off 25 7.5 11 14 3.5 6 8.5 DIULM25/21(RDC24)2) 107025 1 Off 32 10 15 17 4 7 10 DIULM32/21(230V50Hz) 2) 278186 1 Off 32 10 15 17 4 7 10 DIULM32/21(RDC24)2) 107026 1 Off 40 12.5 18.5 23 5 9 12 DIULM40/11(230V50Hz) 2) 278211 1 Off 50 15.5 22 30 6 10 14 DIULM50/11(230V50Hz) 2) 278236 1 Off 65 20 30 35 7 12 17 DIULM65/11(230V50Hz) 2) 278261 1 Off Price See price list Std. pack Information relevant for export to North America Information relevant for export to North America 1) 2) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification 48 Part no. Article no. IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 3211-04 UL Listed, CSA certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 2411-03, 3211-04 UL Listed, CSA certified 1.1 Contactor combinations Reversing combinations 1 Individual components of the combination Spare auxiliary contacts Contactor Q11 Q11 Part no. Contactor Q12 Q12 Circuit diagram Notes Mechanical interlock Part no. DILEM-10 + 11DILEM DILEM-10 + 11DILEM 33 33 34 34 DILEM-10-G + 11DILEM DILEM-10-G + 11DILEM 33 33 + 21 0 22 + 22 21 II 21 22 34 34 14 13 I 14 13 14 14 Q12 Q11 13 13 22 Q12 22 Q11 21 A1 21 A1 Q11 Q12 DILM7-01 + DILA-XHI20 63 63 64 64 DILM7-01 + DILA-XHI20 DILM7-01 + DILA-XHI20 63 63 64 64 DILM9-01 + DILA-XHI20 DILM9-01 + DILA-XHI20 63 63 DILM7-01 + DILA-XHI20 + 21 0 1 22 + 22 21 II + A2 A2 (-)N 22 21 13 14 I 13 14 54 64 64 63 DILM9-01 + DILA-XHI20 DILM9-01 + DILA-XHI20 63 64 64 DILM12-01 + DILA-XHI20 DILM12-01 + DILA-XHI20 63 63 64 64 DILM12-01 + DILA-XHI20 DILM12-01 + DILA-XHI20 63 63 64 64 DILM17-01 + DILA-XHI20 DILM17-01 + DILA-XHI20 63 63 64 64 DILM17-01 + DILA-XHI20 DILM17-01 + DILA-XHI20 63 63 64 64 DILM25-01 + DILA-XHI20 DILM25-01 + DILA-XHI20 63 63 64 64 Q11 53 + Q12 22 Q12 + 54 21 53 22 Q11 A1 21 A1 A2 Reversing contactors A2 + + 1 5 3 63 63 64 64 DILM32-01 + DILA-XHI20 DILM32-01 + DILA-XHI20 63 63 64 64 DILM32-01 + DILA-XHI20 DILM32-01 + DILA-XHI20 63 63 64 64 DILM40 + DILM150-XHI11 DILM40 + DILM150-XHI11 – DILM50 + DILM150-XHI11 DILM50 + DILM150-XHI11 – DILM65 + DILM150-XHI11 DILM65 + DILM150-XHI11 – – 1 3 5 2 4 6 Q12 2 4 6 + + U DILM25-01 + DILA-XHI20 Chapter 1.2 52 Q11 DILM25-01 + DILA-XHI20 Page Accessories Q12 Q11 Accessories 1 Overload relay M1 + V W M 3 DIULM7/21 to DIULM65/11 with mechanical interlock + + + 21 0 22 – + 22 21 II 21 22 14 – + 13 I 14 13 14 Q12 Q11 13 13 22 Q12 22 Q11 21 A1 21 A1 Q11 (-)N 14 Q12 A2 A2 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 49 1.1 1 Contactor relays, contactors Suppressor circuit Ordering DILM...-XSP... Suppressor circuits Voltage For use with Circuit symbol Us Part no. Article no. V RC suppressors 24 - 48 AC 110 - 240 AC DILM7 - DILM15 DILMP20 DILA A1 A2 240 - 500 AC 24 - 48 AC 110 - 240 AC DILM17 - DILM32 DILK12 - DILK25 DILL… DILMP32 - DILMP45 240 - 500 AC 24 - 48 AC 110 - 240 AC DILM40 - DILM95 DILK33 - DILK50 DILMP63 - DILMP200 240 - 500 AC Varistor suppressors 24 - 48 AC 48 - 130 AC DILM7 - DILM15 DILMP20 DILA A1 A2 130 - 240 AC 240 - 500 AC 24 - 48 AC 48 - 130 AC DILM17 - DILM32 DILK12 - DILK25 DILL… DILMP32 - DILMP45 130 - 240 AC 240 - 500 AC 24 - 48 AC 48 - 130 AC DILM40 - DILM95 DILK33 - DILK50 DILMP63 - DILMP200 130 - 240 AC 240 - 500 AC DILM12-XSPR48 281199 DILM12-XSPR240 281200 50 Std. pack Notes 10 Off For AC operated contactors 50 - 60 Hz. DC operated contactors and DILM115 and DILM150 have an integrated suppressor. Note drop-out delay. 10 Off DILM12-XSPR500 281201 10 Off DILM32-XSPR48 281202 DILM32-XSPR240 281203 DILM32-XSPR500 281204 10 Off DILM95-XSPR48 281205 DILM95-XSPR240 281206 DILM95-XSPR500 281207 10 Off DILM12-XSPV48 281208 DILM12-XSPV130 281209 DILM12-XSPV240 281210 10 Off DILM12-XSPV500 281211 10 Off DILM32-XSPV48 281212 DILM32-XSPV130 281213 10 Off DILM32-XSPV240 281214 DILM32-XSPV500 281215 10 Off DILM95-XSPV48 281216 DILM95-XSPV130 281217 10 Off DILM95-XSPV240 281218 DILM95-XSPV500 281219 10 Off Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Price See price list IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 227038 3211-07 UL Listed, CSA certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 10 Off 10 Off 10 Off 10 Off 10 Off 10 Off 10 Off 10 Off 10 Off 10 Off For AC operated contactors 50 - 60 Hz. DC operated contactors and DILM115 and DILM150 have an integrated suppressor. Note drop-out delay. Contactor relays, contactors Suppressor circuit 1.1 Ordering 1 DILM...-XSP... Suppressor circuits Voltage For use with Circuit symbol DILM7 - DILM15 DILMP20 DILA A1 Us Std. pack Notes DILM12-XSPVL48 281220 DILM12-XSPVL240 281221 10 Off For AC operated contactors 50 - 60 Hz. DC operated contactors and DILM115 and DILM150 have an integrated suppressor. Note drop-out delay. DILM32-XSPVL48 281222 10 Off DILM32-XSPVL240 281223 DILM95-XSPVL48 281224 DILM95-XSPVL240 281225 10 Off DILM12-XSPD 101672 10 Off Part no. Article no. V Varistor suppressors with integrated LED 24 - 48 AC 130 - 240 AC 24 - 48 AC 130 - 240 AC 24 - 48 AC 130 - 240 AC Diode suppressor 12 - 250 DC A2 DILM17 - DILM32 DILK12 - DILK25 DILL… DILMP32 - DILMP45 DILM40 - DILM95 DILK33 - DILK50 DILMP63 - DILMP200 DILM7 - DILM15 DILMP20 DILA A1 A2 Price See price list 10 Off 10 Off 10 Off DC operated contactors. Prevention of negative switch-off voltage when the contactor is used together with a safety PLC. Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 227038 3211-07 UL Listed, CSA certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 51 1.1 Contactor relays, contactors Accessories 1 DILM...-XDILM..-XVB, DILM..-XMV For use with Part no. Article no. Price See price list Std. pack Notes Information relevant for export to North America 50 Off – Product Standards Mechanical interlocks For mechanically linking contactors in combinations 0 mm distance between contactors. DILM7 - DILM72 DILA DILM32-XVB 281227 UL File No. UL CCN CSA File No. CSA Class No. NA Certification DILM80 - DILM170 DILM150-XVB 281226 10 Off – Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV 012528 3211-05 UL Listed, CSA certified IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 3211-03 UL Listed, CSA certified Mechanical interlocks DILM7 - DILM15 DILMP20 DILA DILM12-XMV 281196 1 Off DILM17 - DILM38 DILM32-XMV 281197 1 Off DILM40 - DILM72 DILM65-XMV 281198 1 Off DILM80 - DILM170 DILM150-XMV 240081 For two contactors with AC or DC operation arranged vertically or horizontally. Distance between contactors 0 mm, including contactor connector Mechanical lifespan 2.5 x 106 operations. DILM 150-XMV including mounting plate for contactors. Additional auxiliary contact modules possible. 36 Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Product Standards 1 Off UL File No. UL CCN CSA File No. CSA Class No. NA Certification DILM185A, DILM225A, DILM250, DILM300A, DILM400, DILM500, DILM570 DILM500-XMV 208289 DILM580, DILM650 DILM750, DILM820 DILM1000 DILM820-XMV 208288 1 Off 1 Off For contactors with the same or different magnet systems mounted horizontally or vertically, mechanical lifespan 5 x 10 6 operations. No auxiliary contact permitted between mechanical interlock and contactor. Combination only with consecutive installation sizes or DILM185A DILM570. For contactors with the same or different magnet systems mounted horizontally or vertically, mechanical lifespan 5 x 10 6 operations. No auxiliary contact permitted between mechanical interlock and contactor. DILM820-XMV consists of interlock element and mounting plate. Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 2411-03 UL Listed, CSA certified IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 2411-03,3211-04 UL Listed, CSA certified IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 2411-03 UL Listed, CSA certified IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 3211-04 UL Listed, CSA certified IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 3211-04 UL Listed, CSA certified Set of spare parts for mechanical interlock Ball for mechanical interlock, incl. contactor connector. – DILM80 - DILM170 52 DILM150-XMVE 107020 1 Off AUTOMATION AND CONTROL www.eaton.com/seasia-electrical UL/CSA certification not required Contactor relays, contactors Accessories 1.1 DILM...-XP1, DILM...-XS1 For use with 1 Circuit symbol Part no. Article no. Price See price list Std. pack Notes Information relevant for export to North America 4th pole can be broken off AC-1 current carrying capacity of the open contactor increases by a factor of 2.5 Protected against accidental contact in accordance with VDE 0106 Part 100 A cover is included with DILM185-XP1 for protection against accidental contact. Connection cross section for DILM..XP1 Technical data Product Standards Paralleling links for main contacts Consisting of 2 paralleling links DILM7 - DILM15 DILM12-XP1 281193 5 Off DILM17 - DILM32 DILM32-XP1 281194 5 Off DILM40 - DILM72 DILM65-XP1 281195 1 Off DILM80 - DILM170 DILM150-XP1 284769 1 Off DILM185A DILM185-XP1 208292 1 O ff DILM7 - DILM15 DILM12-XS1 281190 20 Off UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 3211-03 UL Listed, CSA certified – Star-point bridges • Designed as toolless plug connection • Use as DILA-XHIT... contactor auxiliary contact 38 Product Standards Product Standards Product Standards DILM17 - DILM32 DILM32-XS1 281191 20 Off DILM40 - DILM72 DILM65-XS1 281192 10 Off • Use as DILA-XHIT... contactor auxiliary contact 38 – DILM80 - DILM170 DILM150-XS1 284768 5 Off – UL File No. UL CCN CSA File No. CSA Class No. NA Certification UL File No. UL CCN CSA File No. CSA Class No. NA Certification UL File No. UL CCN CSA File No. CSA Class No. NA Certification DILM185A - DILM400 DILM500 DILM400-XS1 208291 DILM500-XS1 208290 1 Off 1 Off A cover is included for protection against accidental contact. A cover is included for protection against accidental contact. Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Product Standards UL File No. UL CCN NA Certification AUTOMATION AND CONTROL www.eaton.com/seasia-electrical IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV 012528 3211-05 UL Listed, CSA certified IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV 012528 3211-04 UL Listed, CSA certified IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV 012528 3211-03 UL Listed, CSA certified IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV 012528 3211-03 UL Listed, IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX UL Listed 53 1.1 Contactor relays, contactors Accessories DILM...-XSL Star-delta wiring kit 1 Main current wiring for star-delta combination Including star-point bridge 54 For use with Part no. Article no. Price See price list Std. pack Notes Information relevant for export to North America DILM7/9/12/15 mains contactors DILM7/9/12/15 delta contactors DILM7/9/12/15 star contactors DILM12-XSL 283130 1 Off • Designed for tool-less plug connection • Use as DILA-XHIT... contactor auxiliary contact 38 The following control cables are integrated in addition to electrical interlock: • Q13: A1 - Q15: 21 • Q13: 21 - Q15: A1 • Q13: A2 - Q15: A2 Consists of the following connection bridges: • Mains - delta contactors • Delta - star contactors • Star-point bridge Product Standards DILM17/25/32 mains contactors DILM17/25/32 delta contactors DILM17/25/32 star contactors DILM32-XSL 283131 DILM40/50/65 mains contactors DILM40/50/65 delta contactors DILM40/50/65 star contactors DILM 80/95 mains contactors DILM80/95 delta contactors DILM50/65 star contactors DILM65-XSL 101058 1 Off DILM95-XSL 101486 1 O ff – DILM 115/150 mains contactors DILM115/150 delta contactors DILM80/95/115 star contactors DILM150-XSL 101487 1 Off Product Standards DILM 185/225 mains contactors DILM185/225 delta contactors DILM115/150 star contactors DILM225-XSL 101488 1 Off CSA File No. CSA Class No. NA Certification Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification UL File No. UL CCN CSA File No. CSA Class No. NA Certification 1 O ff AUTOMATION AND CONTROL www.eaton.com/seasia-electrical – IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking 012528 3211-05 UL Listed, CSA certified IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV 012528 3211-04 UL Listed, CSA certified IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV 012528 2411-03,3211-04 UL Listed, CSA certified 1.1 Contactor relays, contactors Accessories DILM...-XRL, DILM...XIP2X Reversing starter wiring kits 1 Main current wiring for reversing combinations For use with Part no. Article no. DILM7 DILM9 DILM12 DILM12-XRL 283108 Price See price list Std. pack Notes Information relevant for export to North America 1 Off Product Standards DILM17 DILM25 DILM32 DILM40 DILM50 DILM65 DILM32-XRL 283109 1 Off • Designed for tool-less plug connection • As auxiliary contact DILA-XHIT...use 38 The following control cables are integrated in addition to electrical interlock: • Q11: A1 - Q12: 21 • Q11: 21 - Q12: A1 • Q11: A2 - Q12: A2 – DILM65-XRL 101057 1 Off – UL File No. UL CCN CSA File No. CSA Class No. NA Certification DILM80 DILM95 DILM115 DILM150 DILM150-XRL 101681 1 Off – Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05;CE marking E36332 NLRV 012528 3211-05 UL Listed, CSA certified IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV 012528 3211-04 UL Listed, CSA certified IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV 012528 2411-03, 3211-04 UL Listed, CSA certified DILM...-XRL, DILM...XIP2X IP2X cover set For use with Part no. Article no. DILM17 DILM25 DILM32 DILM38 DILMP32 DILMP45 Price See price list Std. pack Notes Information relevant for export to North America DILM32-XIP2X 118855 1 Off Each cover set consists of two three-pole and two single-pole covers. UL/CSA certification not required DILM40 DILM50 DILM65 DILM72 DILMP63 DILMP80 DILM65-XIP2X 106491 8 Off 2 covers are required per phase The cover set consists of 8 covers UL/CSA certification not required DILM80 DILM95 DILM115 DILM150 DILM170 DILMP125 DILMP160 DILMP200 ZB150 DILM150-XIP2X 106492 8 Off UL/CSA certification not required AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 55 1.1 Contactor relays, contactors Accessories DILM12-XDSBS Three-phase commoning links 1 Protected against accidental contact, short-circuit proof, Ue = 690 V, Iu = 35 ACan be extended by rotating by mounting – For use with Part no. Article no. DILM7 DILM9 DILM12 DILM15 DILM7 DILM9 DILM12 DILM15 DILM7 DILM9 DILM12 DILM15 Price See price list Std. pack Notes Information relevant for export to North America DILM12-XDSB0/3 240084 5 Off Suitable for 3 contactors. Length 112 mm Product Standards DILM12-XDSB0/4 240085 5 Off Suitable for 4 contactors. Length 157 mm UL File No. UL CCN CSA File No. CSA Class No. NA Certification DILM12-XDSB0/5 240086 5 Off Suitable for 5 contactors. Length 202 mm Std. pack Notes Information relevant for export to North America 5 Off For three-phase commoning link, protected against accidental contact, U e = 690 V, I u = 35 A. Terminal capacities: Stranded 2.5…16 mm 2 Flexible with ferrule 2.5…16 mm 2 AWG14…8 Product Standards Std. pack Notes Information relevant for export to North America 1 Off For top-hat rail 75 mm Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV 012528 2411-03 UL Listed, CSA certified DILM12-XDSBS Incoming connection block For use with Part no. Article no. DILM7 DILM9 DILM12 DILM15 DILM12-XEK 240083 Price See price list UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV 012528 2411-03 UL Listed, CSA certified DILM12-XDSBS Adapter plate Enables clipping on of switches on to DIN rails 56 For use with Part no. Article no. DILM80 DILM95 DILM115 DILM150 DILM170 NZM2-XC75 260215 Price See price list AUTOMATION AND CONTROL www.eaton.com/seasia-electrical UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 489; CSA-C22.2 No.14-05; CE marking E140305 DIHS 022086 1437-01 UL Listed, CSA certified Contactor relays, contactors Electronic timer modules 1.1 DILM32-XTE Electronic timer modules For use with On-delayed, Cannot be combined with top mounting auxiliary contacts Incl. suppressor circuits Off-delayed, auxiliary voltage-free Cannot be combined with top mounting auxiliary contactsIncl. suppressor circuits 1 Std. pack Notes DILM32-XTEE11(RA24) 101440 DILM32-XTEE11(RAC130) 101441 DILM32-XTEE11(RAC240) 101442 1 Off Time range can be selected 0.05 s...1 s 0.5 s...10 s 5 s...100 s DILM32-XTED11-1(RA24) 105210 1 Off Time range 0.05 s...1 s DILM32-XTED11-10(RA24) 104943 DILM32-XTED11-100(RA24) 104946 DILM32-XTED11-1(RAC130) 105211 DILM32-XTED11-10(RAC130) 104944 1 Off 100 … 130 V AC DILM32-XTED11-100(RAC130) 104947 1 Off Time range 0.5 s...10 s Time range 5 s...100 s Time range 0.05 s...1 s Time range 0.5 s...10 s Time range 5 s...100 s 200 … 240 V AC DILM32-XTED11-1(RAC240) 105212 DILM32-XTED11-10(RAC240) 104945 DILM32-XTED11-100(RAC240) 104948 1 Off 1 Off Time range 5 s...100 s DILM32-XTEY20(RA24) 101446 DILM32-XTEY20(RAC130) 101447 DILM32-XTEY20(RAC240) 101448 1 Off Changeover time 1...30 s 50 ms changeover delay Sample circuit Page 92 24 V AC/DC 100 … 130 V AC DILM7 - DILM32 DILMP20 DILMP32-DILMP45 DILA Circuit symbol Part no. Article no. A1 57 65 A2 58 66 200 … 240 V AC 24 V AC/DC 24 V AC/DC DILM7 - DILM32 DILMP20 DILMP32-DILMP45 DILA A1 57 65 A2 58 66 24 V AC/DC 100 … 130 V AC 100 … 130 V AC 200 … 240 V AC 200 … 240 V AC For star-delta applications Cannot be combined with top mounting auxiliary contactsIncl. suppressor circuits 24 V AC/DC 100 … 130 V AC DILM7 - DILM32 DILMP20 DILMP32-DILMP45 DILA A1 57 67 A2 58 68 200 … 240 V AC Price See price list 1 Off 1 Off 1 Off 1 Off 1 Off 1 Off 1 Off 1 Off Time range 0.05 s...1 s Time range 0.5 s...10 s Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 3211-03 UL Listed, CSA certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 57 1.1 Contactor relays, contactors Accessories DIL-SWD..., DILM12-XMC SWD contactor modules 1 SmartWire-DT® module for installation on contactors. One module per contactor Two digital inputs for potential-free contacts. 1 electrical interlock for the surface mounting of reversing starters. Messages: Contactor switch status, status of the digital inputs 1 and 2. Commands: Contactor actuation Two digital inputs for potential-free contacts. 1 electrical interlock for the surface mounting of reversing starters. 1-0-A switch for manual or automatic operation. Messages: contactor switching position, status of the digital inputs 1 and 2, 1-0-A switch position. Commands: Contactor actuation For use with Part no. Article no. DILM(C)7… DILM(C)32 DILM38 DILA DILM(C)7… DILM(C)32 DILM38 DILA Price See price list Std. pack Notes DIL-SWD-32-0011) 118560 5 Off DIL-SWD-32-0021) 118561 5 Off • Take into account the max. current consumption of the contactor coils per SmartWire-DT® line. • A2 terminals must not be bridged. • Wiring sets DILM 12-XRL and PKZM0-XRM12 cannot be used. • Connection terminals for electrical interlocking are not suitable for safety technology. DIL-SWD..., DILM12-XMC Wiring set for motor feeder plug For use with Part no. Article no. PE module with contact plate DILM(C)7 DILM(C)9 DILM(C)12 DILM(C)15 Motor plate with PE module and contact plate Motor plate with PE module and contact plate Price See price list Std. pack Notes DILM12-XMCE 2) 121764 5 Off 35x7.5 (15) mm mounting rail (as per DIN EN 60715) with PE function required. For connection of: PE 0.75 – 4 mm² DILM(C)7 DILM(C)9 DILM(C)12 DILM(C)15 DILM12-XMCP/E 2) 121769 1 Off 35x7.5 (15) mm mounting rail (as per DIN EN 60715) with PE function required. For connection of: L1, L2, L3, PE 0.75 – 2.5 mm² PKZM0/PKE + DILM(C)7 PKZM0/PKE + DILM(C)9 PKZM0/PKE + DILM(C)12 PKZM0/PKE + DILM(C)15 MSC-D(E)-…-M7… MSC-D(E)-…-M9… MSC-D(E)-…-M15… DILM12-XMCP/T2) 121770 1 Off For connection of: L1, L2, L3, PE 0.75 – 2.5 mm² Information relevant for export to North America 1) NA Certification 2) Product Standards NA Certification 58 Request filed for UL and CSA IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking Request filed for UL and CSA AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Contactor relays, contactors Accessories 1.1 DILM...-X... 1 For use with Part no. Article no. Price See price list Std. pack Notes Information relevant for export to North America 4 Off • Tool-less version using tool-less plug connection • RC suppressor • Ambient temperature -25…+60 °C, open. • Insulated material, difficult to ignite according to UL 94. • Weight = 0.05 kg. • UL/CSA approval applied for Product Standards Motor suppressor module Can be used at 380…575 V 50/60 Hz. DILM7 DILM15 DILM12-XMSM 109399 UL File No. UL CCN NA Certification IEC/EN 60947-4-1; UL 508; CE marking E300273 NMTR2 UL Listed Test block Suitable for switching on contactor off-load DILM32-XMAN 110955 1 Off – U L /C S A c e r tific a tio n n o t r e q u ir e d DILM12-XPBC 109400 4 O ff – – DILM17 DILM25 DILM32 DILM38 DILMP32 DILMP45 DILM32-XSPLW24 112419 1 Off Installed in a suppressor circuit enclosure. Required when using special PLC outputs for actuation, e.g.: Beckhoff safety controllers. Product Standards DILM80 DILM95 DILM115 DILM150 DILM170 DILM150-XZK 104486 Can be fitted on every main terminal of the contactor. Connection options: maximum 2 x 4 mm² solid maximum 2 x 2.5 mm² flexible with ferrule Product Standards Connection options: round conductors, flexible and stranded, ribbon cables. Product Standards DILM7 DILM38 DILA Printed board contact For the adaption of a control circuit on a printed-circuit board DILM7 DILM15 DILA Load resistor For DC contactors in order to increase power consumption CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; CSA-C22.2 No.14-05; CE marking 225135 3211-07 CSA certified Extension terminals 10 Off UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05;CE marking E29184 NKCR 012528 2411-03, 2411-04 UL Listed, CSA certified Cable terminal block With control circuit terminal Consisting of three flat ribbon terminals DILM250 DILM300A DILM400 DILM400-XKU-S 208293 1 Off UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05;CE marking E29184 NKCR 012528 3211-04 UL Listed, CSA certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 59 1.1 Contactor relays, contactors Accessories DILM...-XK... Flat strip conductor terminal kit 1 With control cable connection For use with Part no. Article no. DILM580 DILM650 DILM750 DILM820 DILM820-XKB-S 208295 Price See price list Std. pack Notes 1 Off Connection options: ribbon cables Information relevant for export to North America DILM...-XK... Connection terminal sets for North America Consist of three individual terminals Conductor material Cross-section X For use with Part no. Article no. DILM500/22 DILM500-XK-CNA 232192 DILM820-XK-CNA 232194 number of cores mm² Copper, aluminum Copper, aluminum 60 2 x (AWG4 … MCM500) 4 x (AWG2 … MCM500) DILM580/22 DILM650/22 DILM750/22 DILM820/22 Price See price list Std. pack Notes Information relevant for export to North America 1 Off Including cover With control cable connection Product Standards 1 Off AUTOMATION AND CONTROL www.eaton.com/seasia-electrical UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 3211-04 UL Listed, CSA certified Contactor relays, contactors Accessories 1.1 DILM...-XHB, DILM...-XAB Description 1 For use with Part no. Article no. DILM32-XTE… Price See price list Std. pack Notes Information relevant for export to North America DILM32-XTEPLH 101449 1 O ff – – Labelling with laser printer, plotter, film plotter, copier XGKE-GE 207517 25 Off 1 off = 1 sheet 240 labels per sheet 1 sheet = DIN A4, Can be split into two DIN A5 sheets UL/CSA certification not required DILM185A DILM225A DILM250 DILM300A DILM400 DILM500 DILM225A-XHB 139560 DILM400-XHB 208287 1 Off To provide terminals with protection against accidental contact vertical from the front UL/CSA certification not required DILM500-XHB 208286 DILM650-XHB 208285 DILM820-XHB 208284 1 Off DILM400-XS1 DILM400-XHBS1 101687 1 Off Can be combined with stardelta wiring kits DILM250-XSL and DILM400-XSL. UL/CSA certification not required DILM7 - DILM38 DILMP32 DILMP45 DILA DILL DILM40 DILM170 DILMP63 DILMP200 DILM32-XAB 129538 10 Off For preventing manual actuation. Cannot be combined with additional surface mounting accessories UL/CSA certification not required Sealable shrouds Transparent Device labelling, label sheet 7.5 x 17 mm Colour: yellow HKS 3 ( RAL 1018) Covers Terminal cover DILM580 DILM650 DILM750 DILM820, DILM1000 1 Off 1 Off 1 Off Shroud for star-point bridge Auxiliary contact seat cover DILM150-XAB 121712 10 Off DILM1000-XSM 125947 1 Off DILH2600-XSM 125946 1 Off . Suppressor circuits for vacuum contactors (on load side) DILM580 DILM650 DILM750 DILM820 DILM1000 DILH2000 DILH2200 DILH2600 For damping the cutout overvoltage when switching off inductive loads. NA Certification AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Request filed for UL and CSA 61 1.1 Contactor relays, contactors Accessories DILM...-XSP... Amplifier module for separate mounting 1 Input with integrated suppressor circuit for overvoltage limitation Rated operational current AC-15 Actuating voltage Actuating current Circuit symbol For use with Part no. Article no. ...D I L M DIMLP... DILL... DILK... ETS4-VS3 083094 DC 230 V 400 V Ie Ie Ie Us I A A A V DC mA 2 2 0.03 24 25 Price See price list Std. pack Information relevant for export to North America 1 Off Product Standards 220 V 21 13 22 14 UL File No. UL CCN CSA File No. CSA Class No. NA Certification Notes IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV 012528 2411-03, 3211-04 UL Listed, CSA certified Contactor coils with rated operational current > 2 A must be actuated via the DILER-G mini contactor relay. Rated operational current DC: Making and breaking conditions DC-13, time L/R 300ms DILM...-XSP... Individual coils DC voltage For use with Part no. Article no. DILM17 DILM25 DILM32 DILM38 DILM40 DILM50 DILM65 DILM72 DILM32-XSP(RDC24)1) 281155 DILM80 DILM95 DILM115 DILM150 DILM170 DILM185A DILM225A Notes AC voltage Prices See price list Std. pack Notes DILM32-XSP(230V50Hz,240V60Hz) 281141 1 Off For additional actuating voltages Page 75 DILM65-XSP(RDC24)1) 281185 DILM65-XSP(230V50Hz,240V60Hz) 281171 1 Off DILM95-XSP(RDC24)1) 230080 DILM150-XSP(RDC24)1) 230115 DILM95-XSP(230V50Hz,240V60Hz) 230062 DILM150-XSP(RAC240)1) 230112 1 Off DILM225A-XSP(RDC24)1) 139568 DILM225A-XSP(RAC240)1) 139565 1 Off 1) Incl. electronic module Part no. Article no. Price See price list Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification 62 1 Off AUTOMATION AND CONTROL www.eaton.com/seasia-electrical IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 2411-03, 3211-04 UL Listed, CSA certified 1.1 Contactor relays, contactors Accessories DILM...-XSP/E... Electronic modules including coils 1 DC voltage AC voltage For use with Part no. Article no. Price See price list Part no. Article no. DILM250 DILM300A DILM400 DILM500 DILM580 DILM650 DILM750 DILM820 DILM1000 DILM250-XSP/E(RA250)1) 208252 DILM500-XSP/E(RA250)1) 208256 DILM1000-XSP/E(RA250)1) 289145 DILM250-XSP/E(RA250)1) 208252 DILM500-XSP/E(RA250)1) 208256 DILM1000-XSP/E(RA250)1) 289145 DILH1400 – DILH1400-XSP/E(RAW250)2) 289161 1 Off DILM250-S DILM300A-S DILM400-S DILM500-S – DILM250-S-XSP/E(220-240V50/60Hz) 2) 274202 DILM500-S-XSP/E(220-240V50/60Hz) 2) 274205 1 Off – Price See price list Std. pack Notes 1 Off For additional actuating voltages Page 77 1 Off 1 Off 1 Off 1) 2) Information relevant for export to North America Information relevant for export to North America Product Standards Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 1017510 3211-04 UL Listed, CSA certified UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29096 NLDX 012528 3211-04 UL Listed, CSA certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 63 1.1 1 Contactor monitoring devices Description, ordering General Application Mounting For safety-related off switching to safety category 3 and 4 according to EN 954-1, at present two contactors must be used in series. Especially with larger contactors this is an expensive solution. This is where the CMD can be used. The function of the CMD is to monitor the main contacts of a contactor against welding. For this the control voltage of the contactor is compared with the state of the main contacts which is reliably monitored using a mirror contact (IEC EN 60947-4-1 Annex F). If the coil is deenergized and the contactor does not drop out the CMD trips the upstream circuit-breaker/motor protective circuit breaker/switch-disconnector via a shunt release. The CMD can be combined with the following Eaton components: • Contactors: – DILEM – DILM7 to DILM150 – DILM185(-S) to DILM500(-S): – DILM580 to DILM1600 – DILH1400 … DILH2000 – SE-1A-PKZ2 and S-PKZ2 Safety The CMD has a safety-compliant design so that in safety combinations with a circuit-breaker/motor protective circuit breaker/switch disconnector the reliable switch off in the case of a "welded contactor" can be guaranteed. In this application it replaces the series connection of a second contactor. As a component it conforms to safety category 3 according to EN 954-1 and EN ISO 13849. For the wiring of the CMD the auxiliary N/C contact, mirror contact must be according to IEC/EN 60947-4-1 and the auxiliary N/O contact must be interlocked and opposing according to IEC/EN 60947-5-1. Also the auxiliary N/C contact for the feedback circuit must have a mirror contact function according to IEC/EN 60947-4-1. Auxiliary contact requirements per contactor: DOL starter Reversing starter CMD Self maintaining Feedback circuit 1 N/O + 1 N/C 1 N/O + 1 N/C 1S 1B 1S 1B Ordering CMD Part no. Article no. CMD contactor monitoring device 64 • Motor-protective circuit-breakers/ circuit-breakers: – PKZ2 + U-PKZ2(18VDC) – NZM1 + NZM1-XUVL – NZM2 + NZM2/3-XUV – NZM3 + NZM2/3-XUV – NZM4 + NZM4-XUV – N1 + NZM1-XUVL – N2 + NZM2/3-XUV – N3 + NZM2/3-XUV – N4 + NZM4-XUV Price See Price List Std. pack CMD(24VDC) 106170 1 Off CMD(220-240VAC) 106172 1 Off AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Electrical interlock 1B Contactor monitoring devices 1.1 Engineering 1 DOL starter L1 L2 L3 L0 1 L1 L2 L3 L0 1 -F1 L1 L2 L3 1.13 -Q1 1.14 -Q1 21 -Q11 I> I> I> 22 T1 T2 T3 -K 33 -Q11 34 21 -S1 22 TEST -S3 1 3 5 2 4 6 -Q11 PE U -X1 V W 13 -S2 14 13 14 14 -F2 CMD A1 L S21 S22 S13 S14 S31 S32 A2 A1 D1 D2 -Q11 -Q1 A2 U< D2 L0 2 M 3 -M1 13 22 -Q11 PE PE 21 L0 2 1 3 5 13 21 33 ˜ 2 4 6 14 22 34 Reversing starter L1 L01 L2 L3 L1 L2 L3 L01 -F1 L1 L2 L3 1.13 -Q1 1.14 -Q1 21 21 -Q12 -Q11 I> I> I> T1 T2 T3 22 -K 22 43 43 -Q12 -Q11 44 21 44 -S1 22 TEST 13 13 1 -Q11 2 3 5 4 6 1 -Q12 2 3 4 13 -S2 5 6 -S3 -Q11 14 14 21 14 21 22 22 31 PE U -X1 V W PE 31 -Q12 PE -Q11 32 32 A1 A2 13 22 14 S21 S22 S13 S14 S31 S32 D1 D2 -Q 1 -F3 CMD A1 L A2 S21 S22 S13 S14 S31 S32 D1 D2 U< D2 L02 ˜ A1 L A2 -Q12 A2 -M1 14 -F2 CMD 21 -S4 -Q12 A1 -Q11 M 3 13 L02 1 3 5 13 21 31 43 2 4 6 14 22 32 44 1 3 5 13 21 31 43 2 4 6 14 22 32 44 Switching by safety relay of safety PLC Signal contact to PLC evaluation CMD (24VDC) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 65 1.1 1 Mini contactor relays, contactor relays Actuating voltages Ordering DILER, DILEEM AC DILER-40(...) DILER-31(...) DILER-22(...) DILEEM-10(...) DILEEM-01(...) Standard voltages Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list 24V 50Hz 48V 50Hz 240V 50Hz 115V 60Hz 42V 50Hz, 48V 60Hz 010094 010190 010478 010270 – 010251 010044 010300 010204 – 010344 010201 010138 010211 – 051604 051603 051602 051598 051612 051629 051628 051627 051624 051637 110V 50Hz, 120V 60Hz 190V 50Hz, 220V 60Hz 220V 50Hz, 240V 60Hz 230V 50Hz, 240V 60Hz 051756 051765 051774 051611 051636 051757 051766 051775 051610 051635 051758 051767 051776 051609 051634 051759 051768 051777 051608 051633 380V 50Hz, 440V 60Hz 400V 50Hz, 440V 60Hz 415V 50Hz, 480V 60Hz 24V 50/60Hz 051760 051769 051778 051607 051632 051761 051770 051779 051606 051631 051762 051771 051780 051605 051630 021924 021594 021704 051596 051621 42V 50/60Hz 110V 50/60Hz 230V 50/60Hz 033459 021961 052725 029869 021624 052509 029433 021871 052508 051595 051592 056674 051620 051618 058771 DC DILER-40-G(...) DILER-31-G(...) DILER-22-G(...) DILEEM-10-G(...) DILEEM-01-G(...) Standard voltages Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list 12V DC 24V DC 48V DC 110V DC 220V DC 079711 010223 010255 010287 010303 079761 010157 010205 010253 010269 080728 010042 010346 010043 010091 051644 051643 051642 051640 051639 051649 051650 051648 051646 051645 DILER, DILEEM Notes 66 1) To obtain the article number for ordering, read under selected part number and actuating voltage from the table. Devices with dual-voltage coils are to be ordered under a single article number. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Mini contactor relays, contactor relays Actuating voltages 1 DILEM AC DILEM-10(...) DILEM-01(...) DILEM12-10(...) DILEM12-01(...) DILEM4(...) Standard voltages Article no. 1) See price list Article no. 1) See price list Article no. 1) See price list Article no.1) See price list Article no.1) See price list 24V 50Hz 48V 50Hz 240V 50Hz 115V 60Hz 42V 50Hz, 48V 60Hz 110V 50Hz, 120V 60Hz 010005 010020 010032 010024 051782 010086 010294 010151 010470 051791 127067 – – – – 127083 – – – – 014754 – 014305 – – 051783 051792 127072 127088 051801 190V 50Hz, 220V 60Hz 220V 50Hz, 240V 60Hz 230V 50Hz, 240V 60Hz 380V 50Hz, 440V 60Hz 400V 50Hz, 440V 60Hz 415V 50Hz, 480V 60Hz 24V 50/60Hz 42V 50/60Hz 110V 50/60Hz 230V 50/60Hz 051784 051793 – – – 051785 051794 – – 051803 051786 051795 – – 051804 051787 051796 – – – 051788 051797 – – 051806 051789 – – – – 021417 032174 021455 052302 020402 033233 020436 051114 127079 – 127081 127082 127095 – 127097 127098 022044 – – 052506 DC DILEM-10-G(...) DILEM-01-G(...) DILEM12-10-G(...) DILEEM12-01-G(...) DILEM4-G(...) Standard voltages Article no. 1) See price list Article no. 1) See price list Article no. 1) See price list Article no.1) See price list Article no.1) See price list 12V DC 24V DC 48V DC 110V DC 079594 010213 010245 010309 079642 010343 010496 010136 – 127132 – – – 127137 – – 079680 012701 – – 010325 010168 – – – DILEM 220V DC Notes 1) To obtain the article number for ordering, read under selected part number and actuating voltage from the table. Devices with dual-voltage coils are to be ordered under a single article number. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 67 1.1 Contactor relays Actuating voltages 1 DILA AC With screw terminals DILA-40(...) DILA-31(...) DILA-22(...) With Spring-loaded terminals DILAC-40(...) DILAC-31(...) DILAC-22(...) Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list 24V 50Hz 240V 50Hz 110V 50Hz 120V 60Hz 190V 50Hz 220V 60Hz 220V 50Hz 240V 60Hz 230V 50Hz 240V 60Hz 276316 276318 276326 276351 276353 276361 276386 276388 276396 276431 – 276438 276463 – 276470 276495 – 276502 276327 276362 276397 – – – 276328 276363 276398 – – – 276329 276364 276399 276441 276473 276505 380V 50Hz 440V 60Hz 276330 276365 276400 – – – 400V 50Hz 440V 60Hz 24V 50Hz/60Hz 276331 276366 276401 – – – 276333 276368 276403 276445 276477 276509 42V 50Hz/60Hz 110V 50Hz/60Hz 276334 276335 276369 276370 276404 276405 – – – – – – 220V 50Hz/60Hz 230V 50Hz/60Hz Special voltages other than the already shown normal voltages 2) 276336 276337 See price list 276371 276372 See price list 276406 276407 See price list – 276449 See price list – 276481 See price list – 276513 See price list ...V 50Hz(12-500V)3) ...V 60Hz(12-600V)3) 276341 276342 276376 276377 276411 276412 276453 276454 276485 276486 276517 276518 With screw terminals DILA-40(...) DILA-31(...) DILA-22(...) With Spring-loaded terminals DILAC-40(...) DILAC-31(...) DILAC-22(...) Standard voltages Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list 24V DC 48V DC 110V DC 220V DC 276344 276345 276347 276348 276379 276380 276382 276383 276414 276415 276417 276418 276456 – 276459 276460 276488 – 276491 276492 276520 – 276523 276524 Special voltages other than the already shown normal voltages 2) ...V DC(12-250V)3) See price list See price list See price list See price list See price list See price list 276349 276384 276419 276461 276493 276525 Notes 1) Standard voltages DILA DC 2) 3) 68 The article number is a combination of part no. and operating voltage devices with dual-voltage coils can be ordered under a single article no. With non-standard voltages the required actuating voltage from the defined range (...–...V) must be stated. Minimum order quantity 10 units AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Actuating voltages DILM AC 1 DILM7-10 (...) DILM7-01 (...) DILM9-10 (...) DILM9-01 (...) DILM12-10 (...) DILM12-01 (...) DILM15-10 (...) DILM15-01 (...) Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list 24V 50Hz 240V 50Hz 42V 50Hz 48V 60Hz 110V 50Hz 120V 60Hz 190V 50Hz 220V 60Hz 276537 276539 276546 276572 276574 – 276677 276679 276686 276712 276714 – 276817 276819 276826 276852 276854 – 290045 – – 290080 – – 276547 276582 276687 276722 276827 276862 290055 290090 276548 276583 276688 276723 276828 276863 – – 220V 50Hz 240V 60Hz 230V 50Hz 240V 60Hz 380V 50Hz 440V 60Hz 400V 50Hz 440V 60Hz 276549 276584 276689 276724 276829 276864 – – 276550 276585 276690 276725 276830 276865 290058 290093 276551 276586 276691 276726 276831 276866 – – 276552 276587 276692 276727 276832 276867 – – 415V 50Hz 480V 60Hz 24V 50Hz/60Hz 42V 50Hz/60Hz 110V 50Hz/60Hz 276553 – 276693 – 276833 – – – 276554 276555 276556 276589 276590 276591 276694 276695 276696 276729 276730 276731 276834 276835 276836 276869 276870 276871 290062 – – 290097 – – 220V 50Hz/60Hz 230V 50Hz/60Hz Special voltages other than the already shown normal voltages 2) 276557 276558 See price list 276592 276593 See price list 276697 276698 See price list 276732 276733 See price list 276837 276838 See price list 276872 276873 See price list – 290066 See price list – 290101 See price list ...V 50Hz (12 – 600V) 3) 276562 276597 276702 276737 276842 276877 290070 290105 ...V 60Hz (12 – 600V) 3) 276563 276598 276703 276738 276843 276878 290071 290106 DILM7-10 (...) DILM7-01 (...) DILM9-10 (...) DILM9-01 (...) DILM12-10 (...) DILM12-01 (...) DILM15-10 (...) DILM15-01 (...) Standard voltages Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list 24V DC 48V DC 110V DC 220V DC 276565 276566 276568 276569 276600 276601 276603 276604 276705 276706 276708 276709 276740 276741 276743 276744 276845 276846 276848 276849 276880 276881 276883 276884 290073 – – – 290108 – – – Special voltages other than the already shown normal voltages 2) See price list See price list See price list See price list See price list See price list See price list See price list ...V DC (12-250V) 3) 276570 276605 276710 276745 276850 276885 290078 290113 Notes 1) Standard voltages DILM DC 2) 3) To obtain the article number for ordering, read under selected part number and actuating voltage from the table. devices with dual-voltage coils can be ordered under a single article no. With non-standard voltages the required actuating voltage from the defined range (...–...V) must be stated. Minimum order quantity 10 units AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 69 1.1 Contactors Actuating voltages 1 DILM AC DILM17-10 (...) DILM17-01 (...) DILM25-10 (...) DILM25-01 (...) DILM32-10 (...) DILM32-01 (...) DILM38-10(...) DILM38-01(...) Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list 24V 50Hz 240V 50Hz 42V 50Hz 48V 60Hz 110V 50Hz 120V 60Hz 190V 50Hz 220V 60Hz 276991 276993 277000 277023 – – 277119 277121 277128 277151 – – 277247 277249 277256 277279 – – 112378 112420 112424 112446 – – 277001 277033 277129 277161 277257 277289 112425 112454 277002 – 277130 – 277258 – 112426 – 220V 50Hz 240V 60Hz 230V 50Hz 240V 60Hz 380V 50Hz 440V 60Hz 400V 50Hz 440V 60Hz 277003 – 277131 – 277259 – 112427 – 277004 277036 277132 277164 277260 277292 112428 112457 277005 – 277133 – 277261 – 112429 – 277006 277038 277134 277166 277262 277294 112430 112459 415V 50Hz 480V 60Hz 24V 50Hz/60Hz 42V 50Hz/60Hz 110V 50Hz/60Hz 220V 50Hz/60Hz 230V 50Hz/60Hz Special voltages other than the already shown normal voltages 2) ...V 50Hz (24 – 600V) ...V 60Hz (24 – 600V) 277007 – 277135 – 277263 – 112431 – 277008 277009 277010 277011 277012 See price list 277040 – 277042 277043 277044 See price list 277136 277137 277138 277139 277140 See price list 277168 – 277170 277171 277172 See price list 277264 277265 277266 277267 277268 See price list 277296 – 277298 277299 277300 See price list 112432 112433 112434 112435 112436 See price list 112461 – 112463 112464 112465 See price list 277016 7) 277017 7) 277048 7) 277049 7) 277144 7) 277145 7) 277176 7) 277177 7) 277272 7) 277273 7) 277304 8) 277305 8) 112440 7) 112441 7) 112468 7) 112469 7) Standard voltages DILM DC DILM17-10(...) DILM17-01(...) DILM25-10(...) DILM25-01(...) DILM32-10(...) DILM32-01(...) DILM38-10(...) DILM38-01(...) Standard voltages Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list RDC 24 3) RDC 60 4) RDC 130 5) RDC 240 6) 277018 277019 277020 277021 277050 277051 277052 277053 277146 277147 277148 277149 277178 277179 277180 277181 277274 277275 277276 277277 277306 277307 277308 277309 112442 112443 112444 112445 112470 112471 112472 112473 Notes 1) 2) 3) 4) 5) 6) 7) 8) 70 To obtain the article number for ordering, read under selected part number and actuating voltage from the table. devices with dual-voltage coils can be ordered under a single article no. With non-standard voltages the required actuating voltage from the defined range (...–...V) must be stated. 24 – 27 V DC 48 – 60 V DC 110 – 130 V DC 200 – 240 V DC Minimum order quantity 10 units Minimum order quantity 5 units AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Actuating voltages DILM 1 AC DILM40(...) DILM50(...) DILM65(...) DILM72(...) Standard voltages Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list 24V 50Hz 240V 50Hz 42V 50Hz 48V 60Hz 110V 50Hz 120V 60Hz 190V 50Hz 220V 60Hz 277753 277755 277762 277817 277819 277826 277881 277883 277890 – 109183 – 277763 277827 277891 109191 277764 277828 277892 – 220V 50Hz 240V 60Hz 230V 50Hz 240V 60Hz 277765 277829 277893 – 277766 277830 277894 107670 380V 50Hz 440V 60Hz 400V 50Hz 440V 60Hz 415V 50Hz 480V 60Hz 24V 50Hz/60Hz 42V 50Hz/60Hz 110V 50Hz/60Hz 220V 50Hz/60Hz 230V 50Hz/60Hz 277767 277831 277895 – 277768 277832 277896 109195 277769 277833 277897 – 277770 277771 277772 277773 277774 277834 277835 277836 277837 277838 277898 277899 277900 277901 277902 109197 – 109199 109200 109201 Special voltages other than the already shown normal voltages 2) See price list See price list See price list See price list ...V 50Hz (24 – 600V) ...V 60Hz (24 – 600V) 277778 8) 277779 8) 277842 8) 277843 8) 277906 8) 277907 8) 109205 7) 109206 7) DC DILM40(...) DILM50(...) DILM65(...) DILM72(...) Standard voltages Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list RDC 24 3) RDC 60 4) RDC 130 5) RDC 240 6) 277780 277781 277782 277783 277844 277845 277846 277847 277908 277909 277910 277911 107671 – – 109209 DILM Notes 1) 2) 3) 4) 5) 6) 7) To obtain the article number for ordering, read under selected part number and actuating voltage from the table. devices with dual-voltage coils can be ordered under a single article no. With non-standard voltages the required actuating voltage from the defined range (...–...V) must be stated. 24 – 27 V DC 48 – 60 V DC 110 – 130 V DC 200 – 240 V DC Minimum order quantity 10 units AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 71 1.1 Contactors Actuating voltages 1 DILM DILM AC DILM80 (...) DILM95 (...) DILM115 (...) DILM150 (...) DILM170 (...) DILM185A/ DILM225A/ 22(...) 22(...) Article no.1) See price list Article no.1) See price list Standard voltages Article no. 1) See price list Article no. 1) See price list Article no. 1) See price list Article no. 1) See price list Article no. 1) See price list 24 V 50 Hz 240V 50Hz 42V 50Hz 48V 60Hz 110V 50Hz 120V 60Hz 190V 50Hz 220V 60Hz 235904 235910 239394 239467 239469 239476 RAC 247) RAC 488) RAC 1209) 239545 239546 239547 239585 239586 239587 107010 107011 107012 139534 139535 139536 139544 139545 139546 239399 239477 RAC 24010) 239548 239588 107013 139537 139547 239400 239478 RAC 44011) 239549 239589 107014 139538 139548 220V 50Hz 240V 60Hz 230V 50Hz 240V 60Hz 380V 50Hz 440V 60Hz 239401 239479 RAC 50012) 239550 239590 107015 139539 139549 239402 239480 239403 239481 400V 50Hz 440V 60Hz 415V 50Hz 480V 60Hz 24V 50Hz/60Hz 42V 50Hz/60Hz 110V 50Hz/60Hz 220V 50Hz/60Hz 230V 50Hz/60Hz Special voltages other than the already shown normal voltages 2) ...V 50Hz (24 – 600V) 13) ...V 60Hz (24 – 600V) 13) 239404 239482 DILM115 (...) DILM150 (...) DILM170 (...) DILM185A/ DILM225A/ 22(...) 22(...) 239405 239483 239406 239407 239408 239409 239410 See price list 239484 239485 239486 239487 239488 Standard voltages Article no. 1) See price list Article no. 1) See price list Article no. 1) See price list Article no. 1) See price list Article no. 1) See price list RDC 243) RDC 604) RDC 1305) RDC 2406) 239555 239560 239567 239572 239591 239592 239593 239594 107016 107017 107018 107019 139540 139541 139542 139543 139550 139551 139552 139553 Notes 1) Standard voltages 239414 239415 list AC DILM DC 239504 239509 2) DILM DC 3) 4) DILM80 (...) DILM95 (...) Article no.1) See price list 8) Standard voltages Article no.1) See price list RDC 243) RDC 604) 239416 239417 239510 239511 12) RDC 1305) RDC 2406) 239418 239419 239512 239513 5) 6) 7) 72 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 9) 10) 11) 13) The article no. results from combining the part no. and the actuating voltage. Devices with dual-voltage coils must be ordered under a single article no. With non-standard voltages the required actuating voltage from the defined range (...–...V) must be stated. 24 - 27 V DC 48 – 60 V DC 110 - 130 V DC 200 - 240 V DC 24 V 50/60 Hz 42 – 48 V 50/60 Hz 100 – 120 V 50/60 Hz 190 – 240 V 50/60 Hz 380 – 440 V 50/60 Hz 480 – 500 V 50/60 Hz Minimum order quantity 5 units 1.1 Contactors Actuating voltages DILM AC 1 DILMC7-10 (...) Article no.1) See price list DILMC7-01 (...) Article no.1) See price list DILMC9-10 (...) Article no.1) See price list DILMC9-01 (...) Article no.1) See price list DILMC12-10 (...) Article no.1) See price list DILMC12-01 (...) Article no.1) See price list DILMC15-10 (...) Article no.1) See price list DILMC15-01 (...) Article no.1) See price list 277379 277386 277411 277418 277443 277450 277475 277482 277507 277514 277539 277546 293938 293908 293933 293943 277389 277421 277453 277485 277517 277549 293911 293946 277393 277397 See price list 277425 277429 See price list 277457 277461 See price list 277489 277493 See price list 277521 277525 See price list 277553 277557 See price list 293915 293919 See price list 293950 293954 See price list 277401 277402 277433 277434 277465 277466 277497 277498 277529 277530 277561 277562 293923 293924 293958 293959 DILMC7-10 (...) Article no.1) See price list DILMC7-01 (...) Article no.1) See price list DILMC9-10 (...) Article no.1) See price list DILMC9-01 (...) Article no.1) See price list DILMC12-10 (...) Article no.1) See price list DILMC12-01 (...) Article no.1) See price list DILMC15-10 (...) Article no.1) See price list DILMC15-01 (...) Article no.1) See price list 24V DC 110V DC 220V DC Special voltages other than the already shown normal voltages 2) 277404 277407 277408 See price list 277436 277439 277440 See price list 277468 277471 277472 See price list 277500 277503 277504 See price list 277532 277535 277536 See price list 277564 277567 277568 See price list 293926 293929 293930 See price list 293961 293964 293965 See price list ...VDC (12 – 250V) 6) 277409 277441 277473 277505 277537 277569 293931 293966 Standard voltages 24 V 50 Hz 110V 50Hz 120V 60Hz 230V 50Hz 240V 60Hz 24V 50Hz/60Hz 230V 50Hz/60Hz Special voltages other than the already shown normal voltages 2) ...V 50Hz (12 – 600V) 6) ...V 60Hz (12 – 600V) 6) DILM DC Standard voltages DILM AC DILMC17-10 (...) Article no.1) See price list DILMC17-01(...) Article no.1) See price list DILMC25-10 (...) Article no.1) See price list DILMC25-01 (...) Article no.1) See price list DILMC32-10 (...) Article no.1) See price list DILMC32-01 (...) Article no.1) See price list 24 V 50 Hz 110V 50Hz 120V 60Hz 230V 50Hz 240V 60Hz 24V 50Hz/60Hz 220V 50Hz/60Hz 230V 50Hz/60Hz Special voltages other than the already shown normal voltages 2) 277570 277578 277600 277608 277630 277638 277660 277668 277690 277698 277720 277728 277581 277611 277641 277671 277701 277731 277585 277588 277589 See price list 277615 277618 277619 See price list 277645 277648 277649 See price list 277675 277678 277679 See price list 277705 277708 277709 See price list 277735 277738 277739 See price list ...V 50Hz (24 – 600V) 6) ...V 60Hz (24 – 600V) 6) 277593 277594 277623 277624 277653 277654 277683 277684 277713 277714 277743 277744 DILMC17-10 (...) Article no.1) See price list DILMC17-01 (...) Article no.1) See price list DILMC25-10 (...) Article no.1) See price list DILMC25-01 (...) Article no.1) See price list DILMC32-10 (...) Article no.1) See price list DILMC32-01 (...) Article no.1) See price list Standard voltages DILM DC Standard voltages RDC 243) RDC 1304) RDC 2405) Notes 277595 277625 277655 277685 277715 277597 277627 277657 277687 277717 277598 277628 277658 277688 277718 1) The article no. results from combining the part no. and the actuating voltage. Devices with dual-voltage coils must be ordered under a single article no. 2) With non-standard voltages the required actuating voltage from the defined range (...–...V) must be stated. 3) 24 - 27 V DC 4) 110 - 130 V DC 5) 200 - 240 V DC 6) Minimum order quantity 10 units 277745 277747 277748 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 73 1.1 Contactors Actuating voltages 1 DILMP20 AC Standard voltages 240V 50Hz 110V 50Hz 120V 60Hz 230 V 50Hz 240V 60Hz 24V 50/60Hz 230V 50/60Hz DILMP20 (…) Article no.1) See price list – 276967 AC DILMP20 (…) Standard voltages See price list Non-standard voltages 2) See price list RAC 244) RAC 1205) RAC 2406) – – – …V 50Hz (12 – 600V) 3) …V 60Hz (12 – 600V) 3) 276982 276983 DC DILMP20 (…) 276970 276974 276978 DILMP20 (…) Article no.1) Article no.1) Standard voltages See price list Non-standard voltages 2) See price list …V DC (12 – 250V) 3) 276990 24V DC 276985 – RDC 247) Notes 1) The article number is a combination of part no. and actuating voltage 2) For non-standard voltages, state the actuating voltage selected from the range (…–…V) shown. 3) Minimum order quantity: 10 units 4) 24 V 50/60 Hz 5) 100 – 120 V 50/60 Hz 6) 190 – 240 V 50/60 Hz 7) 24 – 27 V DC 74 DILMP20 (…) Article no.1) Article no.1) DILMP20 DC AC AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Actuating voltages DILM...XSP... AC DILM...XSP... DILM32-XSP DILM65-XSP DILM95(...) (...) XSP 1 AC DILM150-XSP (...) DILM225A-XSP (...) Standard voltages Article no.1) See price list Article no.1) See price list RAC 247) RAC 488) RAC 1209) RAC 24010) RAC 44011) RAC 50012) 230109 230110 230111 230112 230113 230114 139562 139563 139564 139565 139566 139567 DILM150-XSP (...) DILM225A-XSP (...) Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list 24V 50Hz 240V 50Hz 24V 60Hz 115V 60Hz 42V 50Hz 48V 60Hz 281130 281132 281134 281136 281137 281160 281162 281164 281166 281167 229984 229986 229988 229990 229994 110V 50Hz 120V 60Hz 190V 50Hz 220V 60Hz 220V 50Hz 240V 60Hz 281138 281168 230058 281139 281169 230059 DILM...XSP... 281140 281170 230061 DC 230V 50Hz 240V 60Hz 380V 50Hz 440V 60Hz 281141 281171 230062 281142 281172 230063 Standard voltages 400V 50Hz 440V 60Hz 415V 50Hz 480V 60Hz 281143 281173 230064 281144 281174 230065 RDC 243) RDC 604) 230115 230116 139568 139569 24V 50Hz/60Hz 42V 50Hz/60Hz 110V 50Hz/60Hz 220V 50Hz/60Hz 230V 50Hz/60Hz Special voltages other than the already shown normalvoltages 2) 281145 281146 281147 281148 281149 See price list 281175 281176 281177 281178 281179 See price list 230066 230067 230068 230073 230074 See price list RDC 1305) RDC 2406) 230117 230122 139570 139571 Standard voltages ...V 50Hz (24 – 600V) ...V 60Hz (24 – 600V) Notes 1) 2) 3) 4) 13) 281153 281154 13) 14) 281183 281184 14) 14) 230078 230079 14) 5) 6) 7) 8) 9) 10) DILM...XSP... DC 11) DILM32-XSP DILM65-XSP DILM95(...) (...) XSP Standard voltages Article no.1) See price list Article no.1) See price list Article no.1) See price list RDC 243) RDC 604) RDC 1305) RDC 2406) 281155 281156 281157 281158 281185 281186 281187 281188 230080 230081 230082 230107 12) 13) 14) To obtain the article number for ordering, read under selected part number and actuating voltage from the table. Devices with dual-voltage coils are to be ordered under a single article number. With non-standard voltages the required actuating voltage from the defined range (...–...V) must be stated. 24 – 27 V DC 48 – 60 V DC 110 – 130 V DC 200 – 240 V DC 24 V 50/60 Hz 42 – 48 V 50/60 Hz 100 – 120 V 50/60 Hz 190 – 240 V 50/60 Hz 380 – 440 V 50/60 Hz 480 – 500 V 50/60 Hz Minimum order quantity 10 units Minimum order quantity 5 units AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 75 1.1 Contactor for capacitors, contactor Actuating voltages 1 DILK, DILMF AC DILK12-11 (...) DILK20-11 (...) DILK25-11 (...) DILK33-10 (...) DILK50-10 (...) Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no. 1) See price list 110V 50Hz, 120V 60Hz 190V 50Hz, 220V 60Hz 230V 50Hz, 240V 60Hz 293985 294007 294029 294051 294073 293986 294008 294030 294052 294074 293988 294010 294032 294054 294076 400V 50Hz, 440V 60Hz Special voltages other than the already shown normal voltages 2) 293990 294012 294034 294056 294078 See price list See price list See price list 293997 293998 294019 294020 294041 294042 – – – – Standard voltages …V 50Hz (24 – 600V) 3) …V 60Hz (24 – 600V) 3) Notes 1) 2) 3) 76 The article no. results from combining the part no. and the actuating voltage. Devices with dual-voltage coils must be ordered under a single article no. With non-standard voltages the required actuating voltage from the defined range (...–...V) must be stated. Minimum order quantity 10 units AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Actuating voltages DILM 1 Complete comfort devices DILM250 /22(...) DILM300A /22(...) DILM400 /22(...) DILM500 /22(...) DILM580 /22(...) DILM650 /22(...) DILM750 /22(...) DILM820 /22(...) DILM1000 /22(...) Voltage variants Article no.1) Article no.1) Article no.1) Article no.1) Article no.1) Article no.1) Article no.1) Article no.1) Article no.1) See price See price See price See price See price See price See price See price See price list list list list list list list list list RDC 48 2) 208199 139554 208207 208211 – – – – – RA 110 3) 208200 139555 208208 208212 208215 208218 208221 208224 – RA 250 4) 208201 139556 208209 208213 208216 208219 208222 208225 267214 RAC 500 5) 6) 208202 139557 208210 208214 208217 208220 208223 208226 – DILM Complete units Standard DILM250 -S/22(...) DILM300A -S/22(...) DILM400 -S/22(...) DILM500 -S/22(...) Voltage variants Article no.1) See price list Article no.1) See price list Article no.1) See price list Article no.1) See price list 110-120V 50/60Hz 274189 139558 274195 274198 220-240V 50/60Hz 274190 139559 274196 274199 DILM Electronic module, incl. coil, for comfort model DILM250-XSP/E(...) DILM500-XSP/E(...) DILM1000-XSP/E(...) Voltage variants Article no.1) See price list Article no.1) See price list Article no.1) See price list RDC 48 2) 208250 208254 – 110 3) 208251 208255 289146 RA 250 4) 208252 208256 289145 208253 208257 289147 RA RAC 500 5) 6) DILM Electronic module, incl. coil, for standard model DILM250-S-XSP/E(...) DILM500-S-XSP/E(...) Voltage variants Article no.1) See price list Article no.1) See price list 110-120V 50/60Hz 274201 274204 274202 274205 220-240V 50/60Hz Notes 1) 2) 3) 4) 5) 6) The article no. results from combining the part no. and the voltage variant. 24 – 48 V DC 48 – 110 V 40 – 60 Hz/48 – 110 V DC 110 – 250 V 40 – 60 Hz/110 – 250 V DC 250 – 500 V 40 – 60 Hz DC on request AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 77 1.1 1 Contactors Contact travel diagrams Engineering DILM, DILA, DILE, DILH DILM, DILA, DILE, DILH The diagrams show the closing and opening travel of the contacts at no load. The diagrams show the closing and opening travel of the contacts at no load. N/O N/O 0 x1 0 x2 0 x1 DILE AC …DILE …DDILE DILE DC DILE… …DDILE DILA-AC DILA-XHI DILA-XHIV DILA-DC DILA-XHI DILA-XHIV DILM7/9 AC DILM32-XHI, DILA-XHI DILA-XHIV DILM7/9 DC DILM32-XHI, DILA-XHI DILA-XHIV AC DILM32-XHI, DILA-XHI DILA-XHIV DILM12/15/P20 DC DILM32-XHI, DILA-XHI 78 x2 NC NC DILM12/15/P20 x1 x2 0 x1 x2 x1 x2 NO early-make 2.0 4.4 2.8 Late-break N/C contact 2.8 4.4 1.9 2.8 N/O 3.2 4.4 NC 0.9 2.8 NC 1.6 4.4 NO early-make 1.06 2.9 N/O 4.0 6.0 x1 x2 N/O 1.9 2.8 NC 0.95 N/O DILA-XHIV DILM17/25/32/P32/P45 Late-break N/C contact 1.86 2.9 Auxiliary N/C 1.8 6.0 N/O 1.9 2.8 Auxiliary N/O 3.2 6.0 NC 0.9 2.8 N/O 3.2 6.0 N/O 1.9 2.85 NC 1.6 6.0 NC 0.95 2.85 NO early-make 2.0 6.0 N/O 1.9 2.8 Late-break N/C contact 2.8 6.0 NC 0.9 2.8 N/O 3.2 6.0 NO early-make 1.06 2.9 NC 1.6 6.0 Late-break N/C contact 1.86 2.9 DILM40/50/65/P63/P80 N/O 5.1 7.5 DILM150-XHI N/O 5.7 7.5 NC 3.9 7.5 NO early-make 3.8 7.5 DILM32-XHI, DILA-XHI DILA-XHIV N/O 1.9 2.8 NC 0.9 2.8 N/O 3.3 4.5 NC 1.0 4.5 Late-break N/C contact 5.4 7.5 N/O 3.2 4.5 N/O 5.7 7.5 NC 1.6 4.5 NC 3.9 7.5 NO early-make 2.0 4.5 N/O 5.5 7.5 Late-break N/C contact 2.8 4.5 NC 3.6 7.5 NO early-make 4.1 7.5 Late-break N/C contact 5.0 7.5 DILM150-XHIV DILM1000-XHI DILM1000-XHIV N/O 3.2 4.5 NC 1.6 4.5 N/O 2.1 2.9 DILM80/95/115/150/170/P125/P160/P200 N/O 8.0 11 NC 0.7 2.9 DILM150-XHI N/O 9.2 11 N/O 2.3 2.9 NC 7.4 11 NC 0.7 2.9 NO early-make 7.3 11 NO early-make 1.1 2.9 Late-break N/C contact 8.9 11 11 DILM150-XHIV Late-break N/C contact 1.9 2.9 N/O 9.2 N/O 2.3 2.9 NC 7.4 11 NC 0.7 2.9 DILM1000-XHI N/O 9.0 11 NC 7.1 11 DILM1000-XHIV NO early-make 7.6 11 Late-break N/C contact 8.5 11 13.0 N/O 3.3 4.5 NC 1.0 4.5 N/O 3.2 4.5 NC 1.6 4.5 DILM185A/225A N/O 10.0 NO early-make 2.0 4.5 DILM1000-XHI N/O 10.0 13.0 Late-break N/C contact 2.8 4.5 NC 8.1 13.0 NO early-make 8.4 13.0 Late-break N/C contact 9.5 13.0 N/O 10.1 13.1 N/O 10.3 13.1 NC 8.4 13.1 13.1 N/O 3.2 4.5 NC 1.6 4.5 DILM1000-XHIV N/O 2.1 2.9 DILM250/300A NC 0.7 2.9 DILM820-XHI N/O 2.3 2.9 NC 0.7 2.9 NO early-make 1.1 2.9 Late-break N/C contact 1.9 2.9 DILM400/500/570 DILM820-XHI N/O 2.3 2.9 NC 0.7 2.9 N/O 3.3 4.5 NC 1.0 4.5 N/O 3.2 4.5 NC 1.6 4.5 NO early-make 2.0 4.5 Late-break N/C contact 2.8 4.5 N/O 3.2 4.5 NC 1.6 4.5 N/O 3.3 4.4 NC 1.0 4.4 N/O 3.2 4.4 NC 1.6 4.4 DILM820-XHIV DILM820-XHIV NO early-make 8.7 Late-break N/C contact 9.8 13.1 N/O 8.9 13.1 N/O 10.3 13.1 NC 8.4 13.1 13.1 NO early-make 8.7 Late-break N/C contact 9.8 13.1 DILM580/650/750/820 N/O 2.0 4.1 DILM820-XHI N/O 7.4 10.5 NC 5.5 10.5 NO early-make 6.0 10.5 Late-break N/C contact 6.8 10.5 DILM1000/1600, DILH1400/2000/2200/2600 N/O 2.0 4.1 DILM820-XHI N/O 7.4 10.5 NC 5.5 10.5 NO early-make 6.0 10.5 Late-break N/C contact 6.8 10.5 DILM820-XHIV DILM820-XHIV AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Contactors Enclosures 1.1 DILE, DILM, SDAINL, DIUL 1 Components Contactor selection Part no. DILE...(-G)(-C) DILE...(-G)(-C) DILE...(-G) DILE...(-G) DILE...(-G) DILM7 to DILM15 With top mounting auxiliary contacts With side mounting auxiliary contacts With overload relay With parallel connector Insulated enclosures – – – – – – – – – – – – • • – • • • – DILM225A DILM250 DILM300A DILM400 DILM500 – – – – – DILM580 DILM650 DILM750 DILM820 DIULE... DIULE... – – – – • • • • • • • • • • • • • • DIULM7 to DIULM12 DIULM17 to DIULM32 DIULM40 to DIULM65 SDAINLEM... • • • • • • – – – – – – SDAINLM12 to SDAINLM22 SDAINLM30 to SDAINLM65 SDAINLM70 to SDAINLM115 • • • – – – Notes CI-K small enclosure Terminal for CI-K enclosure CI enclosure – • – • • • • • – • – – – – – – – – – CI-K3-160-TS CI-K2-145-TS CI23E-150 CI-K3-160-TS CI43E-150 CI43E-200 CI44E-200 CI48-250 – – – – – – – – – – CI48-250 CI48-250 CI48-250 CI48-250 CI48-250 – – – – – – – – – – – – – – – – – – – CI48-250 CI48-250 CI48-250 CI48-250 CI-K3-125-TS – – – – – – • – – – DILM7 to DILM15 DILM17 to DILM32 DILM17 to DILM32 DILM40 to DILM65 DILM40 to DILM65 DILM80 to DILM170 DILM80 to DILM170 DILM185A – – – CI-K1-95-TS CI-K2-145-TS CI-K2-145-AD CI-K2-100-TS CI-K2-145-TS CI-K2-145-TS – • – • – • • See catalog See catalog Insulated PE, N or PEN terminal for enclosure CI-K CI-K3-125-TS CI-K4-160-TS CI23E-150 CI43E-200 CI-K5-125-TS CI-K5-125-M CI-K5-160-TS CI23E-150 CI43E-200 See catalog See catalog AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 79 1.1 1 Contactors UL/CSA-approved rating data for North America DILE, DILA, DILM Rating data for approved types Contactors GENERAL USE Maximum motorrated current I th Open/enclosed Maximum alternating currentmotor rating Single-phase 3-phase 115 V 120 V HP 230 V 240 V HP 200 V 208 V HP 230 V 240 V HP 460 V 480 V HP 575 V 600 V HP A Part no. ½ ¼ ½ 1 1 2 2 3 3 3 5 7½ 7½ 10 15 – – – – – – – – – – – – 1½ 1 1½ 2 3 3 5 5 7½ 10 15 15 15 25 30 – – – – – – – – – – – – 2 1½ 3 3 3 2 3 3 5 7½ 7½ 10 15 20 25 30 40 50 60 60 75 100 125 150 200 200 250 300 350 400 640 5 3 5 10 10 10 15 20 30 40 40 60 75 100 125 125 150 200 250 300 400 400 500 600 700 800 1200 5 5 7½ 10 10 15 20 25 40 50 60 75 100 125 125 150 200 250 300 400 500 600 600 700 860 1000 1300 15/13.5 20 20 20 20 35 35 40 55 65 80 125 125 160 160 225 250 350 350 450 550 630 700 800 850 1000 1600 DILEM(4) DILM7-...(...) DILM9-...(...) DILM12-...(...) DILM15-...(...) DILM17-...(...) DILM25-...(...) DILM32-...(...), DILM38-...(...) DILM40(...) DILM50(...) DILM65(...), DILM70(...) DILM80(...) DILM95(...) DILM115(...) DILM150(...), DILM170(...) DILM185(...) DILM225(...) DILM250(...) DILM300(...) DILM400(...) DILM500(...) DILM580(...) DILM650(...) DILM750(...) DILM820(...) DILM1000(...) DILM1600(...) 5 7½ 10 10 15 20 25 25 40 40 50 60 75 100 125 150 200 200 250 290 350 560 NEMA size Further approvals 81 • Elevator control • Refrigeration control • Resistance air heating • Incandescent lamps • Electrical discharge lamps • Capacitive switching DILE, DILA, DILM Approved rating data UL -File No. E29184 for auxiliary contacts Pilot Duty AC General Use DC Part no. AC V A DC V A DIL(E)EM-10(-01) DILER-40(31)(22) ...(D)DILE A600 P300 600 10 250 0.5 DILM7-10(-01) To DILM32-10(-01) DILA... DILA-XHI... DILM32-XHI... DILM...-XHI11-SI DILM...-XHI11-SA DILM...-XHI11V-SI A600 P300 600 15 250 1 A600 P300 600 15 250 1 A600 P600 600 10 – – 80 00 00 00 0 0 0 1 1 2 2 2 3 3 4 4 4 4 5 5 5 6 6 6 6 6 7 8 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors UL/CSA special purpose rating for North America 1 DILM, DILMP, DILK Special purpose rating DIL Electrical discharge lamps (ballast) 480V 60Hz 3phase, 277V A 60Hz 1phase 600V 60Hz 3phase, 347V A 60Hz 1phase Incandescent lamps (Tungsten) M7 M9 M12 M15 M17 M25 MP32 MP45 M32 M40 MP63 M50 MP80 M65 M72 M80 MP125 M95 MP160 M115 M150 M170 MP200 12 18 20 20 27 35 40 63 79 88 85 100 136 160 12 18 20 20 27 35 40 63 79 88 85 100 136 160 480V 60Hz 3phase, 277V 60Hz 1phase 600V 60Hz 3phase, 347V 60Hz 1phase Resistance air heating A 8 11 14 14 23 32 40 55 74 88 85 100 136 160 A 8 11 14 14 23 32 40 55 74 88 85 100 136 160 480V60Hz 3phase, 277V60Hz 1phase 600V60Hz 3phase, 347V60Hz 1phase Refrigeration control (CSA only) LRA 480V 60Hz 3phase LRA 600V 60Hz 3phase 480V 60Hz 3phase A 12 18 20 20 27 35 40 63 79 88 94 110 136 160 A 12 18 20 20 27 35 40 63 79 88 94 110 136 160 A A A 60 60 6 60 60 7.5 60 60 10 60 60 10 240 180 23 240 180 32 240 180 40 270 270 26 270 270 36 270 270 45 540 420 63 540 420 70 540 540 84 540 540 90 600V 60Hz 3phase Elevator control A 6 7.5 10 10 17 24 30 26 36 45 63 70 84 90 200V 60Hz 3phase HP (A) ¾ (3.7) 2 (7.8) 2 (7.8) 2 (7.8) 3 (11) 3 (11) HP (A) 1½ (6.0) 2 (6.8) 2 (6.8) 3 (9.6) 3 (9.6) 5 (15.2) 7½ (25.3) 10 (28) 10 (32.2) 15 (42) 10 20 (32.2) (62.1) 15 (42) 25 (68) 20 (62.1) 30 (80) 30 (92) 30 (92) 240V 60Hz 3phase 7½ (25.3) 7½ (22) 480V 60Hz 3phase HP (A) 2 (3.4) 60 (77) 75 (96) 75 (96) 3 (3.9) 7½ 10 (14) 20 (27) 25 (34) (11) 10 (11) 15 (17) 20 (22) 30 (32) 30 (40) 50 (65) HP (A) 7½ (11) 7½ (9.6) 30 (40) 600V 60Hz 3phase 3 (4.8) 7½ (11) 5 (6.1) 7½ (9.6) 40 (41) 40 (41) 60 (62) 75 (77) 100 (99) 40 (104) 40 (104) 100 (99) DILM, DILMP, DILK Special purpose rating DIL K12 K20 K25 K33 K50 Capacitor Switching 240V 60Hz 3phase A 18 28 36 48 72 480V 60Hz 3phase 600V 60Hz 3phase A A 18 14.4 28 28 36 38.4 48 48 72 72 240V 60Hz 3phase 480V 60Hz 3phase 600V 60Hz 3phase kvar kvar kvar 7.5 15 15 12 20 30 15 30 40 20 40 50 30 60 75 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 81 1.1 1 Contactors UL/CSA short circuit current rating for North America DILM Short circuit current rating (SCCR) Contactor Basic Rating Max. fuse kA A Max. CB A 480 V High Fault Max. fuse kA A kA Max. CB A 600 V High Fault Max. fuse kA A kA Max. CB A DILM7-…(…) DILM9-…(…) DILM12-…(…) 5 5 5 45 45 45 60 60 60 100 100 100 20 Class J 20 Class J 20 Class J - Fuse only Fuse only Fuse only 30 30 30 25 25 25 - Fuse only Fuse only Fuse only DILM15-…(…) DILM17-…(…) 5 5 45 125 60 125 100 20 Class J 70 Class J 10 Fuse only 50 30 10 25 125 10 Fuse only 50 DILM25-…(…) DILM32-…(…) DILM38-…(…) DILM40(…) DILM50(…) DILM65(…) 5 5 5 10 10 10 125 125 125 250 250 250 125 125 125 250 250 250 100 100 100 100 100 100 100 Class J 125 Class J 125 Class J 150 Class J 150 Class J 150 Class J 10 10 10 65 65 65 50 50 50 100 100 100 10 10 10 30 30 30 125 125 125 250 250 250 10 10 10 30 30 30 50 50 50 250 250 250 DILM72(…) DILM80(…) 10 10 250 600 250 600 100 100 150 Class J 300 Class J 65 65 100 250 30 30 250 300 30 30 250 350 DILM95(…) DILM115(…) DILM150(…) DILM170(…) 10 10 10 10 600 600 600 600 600 600 600 600 100 100 100 100 300 Class J 300 Class J 300 Class J 300 Class J 65 65 65 65 250 250 250 250 30 30 30 30 300 300 300 300 30 30 30 30 350 350 350 350 DILM185(…) DILM225(…) DILM250(…) DILM300(…) 18 18 18 30 700 700 700 800 600 600 600 600 - CB only CB only CB only CB only 65 65 65 42 250 250 250 600 30 800 30 600 DILM400(…) DILM500(…) DILM570(…) 30 30 30 800 800 800 600 600 600 - CB only CB only CB only 42 42 42 600 600 600 30 30 30 800 800 800 30 30 30 600 600 600 DILM580(…) DILM650(…) DILM750(…) DILM820(…) DILM1000(…) DILM1600(…) 30 30 42 42 85 85 2000 2000 2000 2000 2000 2000 1200 1200 1200 1200 1200 - 85 85 85 85 85 85 2000 2000 2000 2000 2000 2000 85 85 85 85 85 - 1200 1200 1200 1200 1200 - 85 85 85 85 85 85 2000 2000 2000 2000 2000 2000 85 85 85 85 85 85 1200 1200 1200 1200 1200 - 82 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Contactors for resistive load 1 DILM, DILEM Rating data Single-phase rating AC-1 1 2 3 4 5 6 7 Three-phase rating AC-1 ) 1 1 3 5 2 4 6 8 Voltage in V 220 380 230 400 240 440 660 690 Max. upstream fuse gG/gL kW kW kW Three-phase rating AC-1 Voltage in V 220 380 230 400 240 440 660 690 Max. upstream fuse gG/gL A Rated operational current I e = Ith or Ithe A kW kW kW 1 3 5 7 1 3 5 7 1 3 5 7 1) 2 4 6 8 2 4 6 8 2 4 6 8 Voltage in V 220 380 230 400 240 440 660 690 Max. upstream fuse gG/gL A Rated operational current I e = Ith or Ithe A kW kW kW A Rated operational current I e = Ith or Ithe A Open version 10 10 18 18 31 31 50 50 50 50 7 7 13 13 20 20 20 20 20 20 18 18 31 31 54 54 50 50 50 50 12 21 37 63 60 – – – – – 21 37 65 63 60 10 18 31 – 50 7 13 22 – 20 18 31 54 – 50 13 18 22 32 38 55 – – 60 88 – 13 – 22 – 38 – – – 35 22 32 38 55 65 95 – – 60 88 21 36 63 – 100 14 25 43 – 40 36 63 109 – 100 26 45 78 – 125 18 31 54 – 50 45 78 136 – 125 34 59 102 – 163 24 41 71 – 65 59 102 176 – 163 42 72 125 – 200 29 50 87 – 80 72 125 217 – 200 47 81 141 – 225 33 56 98 – 90 81 141 244 – 225 57 99 172 – 275 40 69 119 – 110 100 172 299 – 275 68 117 204 – 325 47 81 141 – 130 118 203 353 – 325 84 144 251 – 400 58 100 174 – 160 145 250 434 – 400 101 175 317 – 460 70 120 220 – 185 175 302 549 – 460 144 248 431 800 688 100 172 299 315 275 262 453 786 – 688 165 284 494 800 788 114 197 342 315 315 300 519 900 – 788 172 297 516 1000 825 120 206 357 400 330 333 576 1000 – 875 183 316 548 1000 875 126 219 380 400 350 381 658 1143 – 1000 261 451 784 1250 1250 181 313 543 500 500 476 825 1429 – 1250 366 632 1097 – 1750 253 438 760 800 700 667 1152 2000 – 1750 418 722 1254 – 2000 290 500 869 800 800 762 1316 2286 – 2000 444 767 1332 – 2125 308 531 923 1000 850 810 1400 2429 – 2125 470 812 1411 – 2250 326 563 977 1000 900 857 1480 2572 – 2250 523 903 1568 – 2500 362 625 1086 1000 1000 953 1646 2858 – 2500 732 1264 2195 – 3500 507 875 1520 – 1400 1334 2300 4000 – 3500 1045 1805 3135 – 5000 724 1251 2172 – 2000 1905 3290 5716 – 5000 1150 1985 3449 – 5500 796 1376 2389 – 2200 2095 3619 6288 – 5500 1358 2346 4075 – 6500 941 1626 2827 – 2600 2476 4277 7430 – 6500 Notes 84 1) Contact 7 – 8 only with DILEM4(-G), DILMP20... AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Contactors Contactors for resistive load 1.1 DILM, DILEM Part no. 1 Ordering data Required accessories: Notes Paralleling links AC operated Page Part no. DILEM-10(…) 4 P1DILEM DILEM-01(…) 4 P1DILEM DILEM4(…) 4 P1DILEM DILM7-…(…) 18 DILM12-XP1 DILMP20(…) DILM17-…(…) 34 18 DILM12-XP1 DILM32-XP1 DILM25-…(…) 18 DILM32-XP1 DILM40(…) 20 DILM65-XP1 DILM50(…) 20 DILM65-XP1 DILM65(…) 20 DILM65-XP1 DILM80(…) 20 DILM150-XP1 DILM95(…) 20 DILM150-XP1 DILM115(…) 20 DILM150-XP1 DILM150(…) 20 DILM150-XP1 DILM170(…) 20 DILM150-KP1 DILM185A(…) 30 DILM185-XP1 DILM225A(…) 30 DILM185-XP1 DILM250(…) 30 – DILM300A(…) 30 – DILM400(…) 30 – DILM500(…) 30 – DILM580(…) 30 – DILM650(…) 30 – DILM750(…) 30 – DILM820(…) 30 – DILH1400(…) 32 – DILH2000(…) 32 – DILH2200(…) 32 – DILH2600(…) 32 – Accessories Auxiliary contact modules Set of paralleling links Enclosure Accessories Page 6 36 53 63 52 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 85 1.1 Mini contactor relays, contactor relays Electrical lifespan DILA DC 1) 1 DILA (AC-15) Component lifespan (operations) Ie = Rated operational current Component lifespan (operations) Ie = Rated operational current x 106 X 10 6 20 20 10 10 5 5 2 2 1 1 0.5 0.5 DC AC-15 0.2 0.2 240 V 0.1 0.01 0.02 0.05 0.1 0.2 0.5 1 2 5 10 A 24 V L 50 ms R 0.1 0.01 0.02 0.05 0.1 0.2 Ie contacts in series DILER (AC-15) Component lifespan (operations) Ie = Rated operational current x 106 20 10 5 2 1 0.5 AC-15 240 V 0.1 0.01 0.02 0.05 0.1 0.2 0.5 1 2 5 10 A Ie 86 1 2 5 10 A Ie 1) Three 0.2 0.5 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Contactors Switching conditions 1.1 kW 90 75 55 45 37 30 22 18.5 15 11 7.5 5.5 4 3 Rated operational current I e 50 – 60 Hz Rated output of three-phase motors 50 – 60 Hz Normal switching duty 1 AC-3/400V A 170 150 115 95 80 65 50 40 32 25 DILM170 DILM150 DILM115 DILM80 DILM95 DILM72 DILM65 DILM50 DILM40 DILM38 DILM32 DILM25 18 DILM17 DILM15 DILM12 12 9 7 DILM9, DILEM DILM7 5 4 DILEM12 DILEM-G 3 DILEM 2 0.01 0.02 0.04 0.06 0.1 0.4 0.6 0.2 1 2 4 6 10 Normal AC induction motor Operating characteristics Make: from stop Break: during run Electrical characteristics: Make: up to 6 X rated motor current Break: up to 1 X rated motor current Utilization category 100 % AC-3 Typical applications: Lifts Compressors Mixers Escalators Agitators Pumps Fan Centrifuges Conveyor belts Air conditioning sysBucket-elevator Hinged flaps General drives for manufacturing and processing machines Component lifespan [millions of operations] 560 450 400 355 315 250 200 160 132 110 90 A 1600 DILM1600 Rated operational current I e 50 – 60 Hz Rated output of three-phase motors 50 – 60 Hz kW 900 AC-3/400 V DILM1000 1000 820 750 650 580 DILM820 DILM750 DILM650 DILM580/570 500 400 300 DILM500 DILM400 DILM300A 250 225 185 DILM250 DILM225A DILM185A 75 145 55 104 45 85 37 72 30 58 22 18.5 43 36 15 30 11 7.5 23 16 0.01 DILM570 0.04 0.06 0.1 0.02 0.2 0.4 0.6 1 2 3 4 5 6 8 10 Component lifespan [millions of operations] Extreme switching duty 19 17 15 9 7.5 5.5 4 3.5 2.5 Rated operational current Ie 50 – 60 Hz Rated output of three-phase motors 50 – 60 Hz 52 47 41 33 Normal AC induction motor Operating characteristics Inching, plugging, reversing Electrical characteristics: Make: up to 6 X rated motor current Break: up to6 X rated motor current Utilization category 100 % AC-4 Typical applications: Printing machines Wire-drawing Centrifuges Special drives on manufacturing and processing machines AC-4/400V A kW 100 DILM150, DILM170 DILM115 90 80 DILM95 DILM80 66 40 DILM65, DILM72 DILM50 35 32 DILM40 20 DILM32, DILM38 DILM25 17 13 9 DILM12.15 DILM9 8.3 6.5 DILM7 5 4 3 DILEM12, DILEM 2 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 1 2 4 6 10 Component lifespan [millions of operations] AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 87 1.1 Contactors Switching conditions 1 Extreme switching duty Rated operational current I e 50 – 60 Hz Rated output of three-phase motors 50 – 60 Hz kW 750 450 355 315 280 250 200 160 132 110 90 75 55 45 37 30 22 18.5 15 800 656 576 512 456 360 296 240 200 164 140 Normal AC induction motor Operating characteristics Inching, plugging, reversing Electrical characteristics: Make:up to 6 X rated motor current Break: 6 X rated motor current Utilization category 100% AC-4 Typical applications: Centrifuges Printing Wiremachines drawing machines Special drives on manufacturing and processing machines DILM1000 DILM820 DILM750 DILM650 DILM580 DILM500/570 DILM400 DILM300A DILM250 DILM225A DILM185A 104 85 72 58 43 36 30 11 23 7.5 16 5.5 12 4 8.8 6.5 3 AC-4/400 V A 1280 DILM1600 2.2 5 1.5 3.5 0.02 0.03 0.04 0.06 0.1 0.01 0.2 0.3 0.4 0.6 1 2 3 4 5 6 8 10 Component lifespan [millions of operations] Breaking current A Switching conditions for 3 pole, non-motor loads 2600 2200 2000 1800 1400 DILH2600 DILH2200 DILH2000 DILM1600 AC-1/400 V DILM1400 1000 900 850 800 700 500 400 350 300 275 160 130 110 90 80 65 DILM820/1000 DILM650 DILM750 DILM500 Operating characteristics Non inductive and slightly inductive loads Electrical characteristics: Make: 1 X rated operational current Break:1 X rated operational current Utilization category 100% AC-1 Typical applications: Electric heat DILM580/570 DILM750 DILM400 DILM300 DILM250 DILM225 DILM185 DILM150, M170 DILM115 DILM95 DILM65 DILM50 50 40 35 DILM40 20 DILEM DILM80 DILM72 DILM25, M32; M38 DILM17 DILM 7, M 9, M 12 , 10 M15 7 5 4 3 2 1 0.1 0.2 0 .3 0 .5 0.7 1 2 3 5 7 10 Component lifespan [Millions of operations] 88 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Contactors Switching conditions 1.1 Switching conditions for 4 pole, non-motor loads 1 Breaking current A AC-1/400 V 200 DILMP200 160 DILMP160 125 DILMP125 80 DILMP80 63 DILMP63 45 DILMP45 32 DILMP32 DILMP20 22 0.1 Operating characteristics Non inductive and slightly inductive loads Electrical characteristics: Make: 1 X rated operational current Break: 1 X rated operational current Utilization category 100% AC-1 Typical applications: Electric heat 0.2 0.4 0.6 1 2 4 6 10 Component lifespan [Millions of operations] AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 89 1.1 Contactors Short-time loading 1 Short-time loading 3 pole Time interval between two loads: 15 minutes AC-1/400 V Short-time current A 700 600 DILM65, M72 500 DILM50 450 DILM40 400 350 DILM32, M38 300 DILM25 250 200 DILM17 150 120 100 90 70 DILM12, M15 DILM7, M9 DIL(E)M(-12) DILE(E)M(-12) 50 40 30 20 15 5 3 2 7 20 10 30 50 70 100 Duration of load Short-time current A 19000 10000 8000 6000 200 300 3 min 5 min 500 700 900 Seconds 10 min 15 min AC-1/400 V DILM1600 DILM820 DILM750 DILM650 DILM580 DILM570 DILM500 DILM1000, DILH1400 DILH 5000 4000 1 min 2000 /220 0/26 00 DILM400 DILM300A 3000 2500 DILM250 2000 1800 1500 DILM185A/225A 1100 1000 DILM80/95 DILM115,150,170 700 500 400 300 200 2 3 5 7 10 20 Duration of load 90 30 50 70 100 1 min 200 300 500 700 900 Seconds 3 min 5 min 10 min 15 min AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Operating frequency Determination of the maximum operating frequency dependent on the rating and utilization category (recommended values) for 400 V P N = max. rated motor output (kW) of respective contactor according to Page 18 and 1 Page 4 S/h = max. operation per hour Ops./h DILEM, DILM, DILH 6000 Part no. Characteristic AC-1 AC-3 AC-2 AC-4 7 3 3 3 3 6 1 2 2 4 8 5 5 5 5 4000 DILE(E)M(-12) DILM7, 9, 12, 15 DILM17, 25, 32, 38 DILM40, 50, 65, 72 DILM80, 95, 115, 150, 170 2000 1000 800 600 400 200 100 0 10 20 30 40 50 60 70 80 90 100 % N [kW] Determination of the maximum operating frequency dependent on the rating and utilization category (recommended values) P N = max. rated motor output (kW) of respective contactor according to Page 28 and Page 32 S/h = max. operation per hour Ops./h DILEM, DILM, DILH 4000 Part no. 3000 DILM185A DILM225A DILM250 DILM300A DILM400 DILM500 DILM580 DILM650 DILM750 DILM820 DILM1000 DILM1600 DILH1400 DILH2000 DILH2200 DILH2600 2000 1500 1000 800 600 500 400 300 200 150 100 Characteristic AC-1 2 2 2 3 3 3 3 3 3 3 3 10 10 10 10 10 AC-3 1 1 1 2 2 2 4 4 4 4 4 10 – – – – AC-4 8 8 8 9 9 9 7 7 7 7 7 7 – – – – 50 0 10 20 30 40 50 60 70 80 90 100 % PN [kW] AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 91 1.1 Contactors Switching of DC current 1 DC current switching – – – – – when necessary conductor to be supplied by customer DILEEM ... DILM700 Without overload relay 60 V DC 1 pole 2 pole DILEM4 DILMP... 1 pole 2 pole Wiring, star-delta combination with DILM32-XTEY20 L0 1 L0 1 95 -F1 96 0 14 -Q11 I 13 57 -K1 58 67 -K1 22 -Q15 22 -Q13 21 A1 -K1 A2 L0 2 92 21 A1 -Q11 -Q13 A1 -Q15 A2 N 68 A2 L02 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical > 60 V DC With overload relay > 60 V DC 1.1 Mini contactor relays, contactor relays Technical data 1 DILER, DILA DILA DILA…XHI DILER DILE… General Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated Operations x 10 6 20 10 10 10 DC operated Operations x 10 6 20 10 20 20 9000 9000 9000 9000 Maximum operating frequency Maximum operating frequency Operations/h Climatic proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open °C -25…60 -25…60 -25…50 -25…50 Enclosed °C -25…40 -25…40 -25…40 -25…40 Ambient temperature for storage °C -40 - 80 -40 - 80 Mounting position Any, except vertically with terminals A1/A2 below 180° ° 90 ° 90 90 ° 30° – Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 ms Basic devices with auxiliary contact module N/O g 7 7 10 NC g 5 5 8 8 IP20 IP20 Finger- and back-of-hand proof IP20 IP20 Protection type Protection against direct contact when actuated from front (EN 50274) 10 Weight AC operated kg 0.23 0.05 0.17 – DC operated kg 0.28 0.05 0.2 – Solid mm 2 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) Flexible with ferrule mm 2 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) Solid or stranded AWG 18 - 14 18 - 14 18 - 14 18 - 14 M3.5 M3.5 M3.5 M3.5 Terminal capacity Screw terminals Terminal screw Pozidriv screwdriver Size 2 2 2 2 Flat-blade screwdriver mm Max. tightening torque Nm 0.8 x 5.5 1x6 1.2 0.8 x 5.5 1x6 1.2 0.8 x 5.5 1x6 1.2 0.8 x 5.5 1x6 1.2 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 18 - 14 1 x (1 - 2.5) 2 x (1 - 2.5) 1 x (1 - 2.5) 2 x (1 - 2.5) – 1 x (1 - 2.5) 2 x (1 - 2.5) 1 x (1 - 2.5) 2 x (1 - 2.5) – 0.6 x 3.5 1 x (16 - 14) 2 x (16 - 14) 0.6 x 3.5 1 x (16 - 14) 2 x (16 - 14) 0.6 x 3.5 Spring-loaded terminals Solid mm² Flexible with ferrule mm² Flexible without ferrule DIN 46228 mm² Solid or stranded AWG 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 mm 0.6 x 3.5 Flat-blade screwdriver AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 93 1.1 Mini contactor relays, contactor relays 1 DILER, DILA Contacts Interlocked opposing contacts to EN 60947-4-1, Annex L, including auxiliary contact module Rated impulse withstand voltage U imp DILA DILA…XHI DILER DILE… Yes Yes Yes Yes V AC 6000 6000 6000 6000 Ui V AC III/3 690 III/3 690 III/3 690 III/3 690 Ue V AC 690 500 600 600 Between coil and auxiliary contacts V AC 400 400 300 300 Between the auxiliary contacts V AC 400 400 300 300 Overvoltage category/degree of pollution Rated insulation voltage Rated operating voltage Safe isolation according to EN 61140 Rated operational current AC-15 220/240 V Ie A 4 4 6 4 380/415 V Ie A 4 4 3 2 500 V Ie A 1.5 1.5 1.5 1.5 DC 1) L/R 15 ms Contacts in series: 1 24 V A 10 10 2.5 2.5 1 2 60 V 60 V A A 6 10 6 10 – 2.5 – 2.5 1 110 V A 3 3 – – 3 110 V A 6 6 1.5 1.5 1 220 V A 1 1 – – 3 220 V A 5 5 0.5 0.5 3 24 V A 4 2.5 – – 3 60 V A 4 1 – – 3 110 V A 2 0.5 – – 3 220 V A 1 0.25 – – 3 24 V A 2.5 2.5 – – 3 60 V A 1 1 – – 3 110 V A 0.5 0.5 – – 3 220 V A 0.25 0.25 – – L/R 50 ms Contacts in series: DC-13 (6xP) Contacts in series: Control circuit reliability (at U e = 24 V DC, Umin = 17 V, Imin = 5.4 mA) Fault probability Conventional thermal current I th <10 -8 , < one failure in 100 million operations A 16 16 10 10 220/240 V PKZM0 4 – 4 4 380/415 V PKZM0 4 – 4 4 A gG/gL 10 10 6 6 A fast – – 10 10 AC operated W 0.3 0.3 0.2 0.2 DC operated W 0.3 0.3 0.3 0.3 Short-circuit strength without welding Maximum overcurrent protection device Short-circuit protection rating maximum fuse 2) 500 V 500 V Current heat loss at load of I th Notes 94 1) Switch-on and switch-off conditions based on DC-13, time constant as specified 2) See characteristic curve "Fuses" for time/current characteristics (please enquire) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Mini contactor relays, contactor relays DILER, DILA 1 DILA DILA…XHI DILER DILE… Magnet systems Voltage tolerance AC operated Single-voltage coil 50 Hz and dualvoltage coil 50 Hz, 60 Hz Dual-frequency coil 50/60 Hz Pick-up x Uc 0.8…1.1 – 0.8…1.1 – Pick-up x Uc 0.8…1.1 – 0.85…1.1 – Pick-up Pick-up x Uc x Uc 0.8…1.1 – 0.85…1.3 – 0.7 - 1.3 – 0.7 - 1.3 – DC operated 1) Starting voltage At 24 V: without auxiliary contact module (40 °C) Power consumption 50 Hz Pick-up VA 24 – 25 – 50 Hz Sealing VA 3.4 – 4.6 – 50 Hz Sealing W 1.2 – 1.3 – 60 Hz Pick-up VA 30 – 25 – 60 Hz Sealing VA 4.4 – 4.6 – 60 Hz Sealing W 1.4 – 1.3 – 50/60 Hz Pick-up VA – Sealing VA 50/60 Hz Sealing W DC operated Pick-up = sealing W – 30 29 5.4 3.9 1.6 1.1 2.6 – 50/60 Hz 27 25 4.2 3.3 1.4 1.2 3 – % DF 100 – 100 – AC operated closing delay ms 15 - 21 – 14 - 21 – AC operated normally open contact opening delay AC operated with auxiliary contact module, max. closing delay DC operated closing delay ms 9 - 18 – 8 - 18 – ms – – 45 45 Duty factor Changeover times at 100 % U c (recommended values) – – – – ms 31 – 26 - 35 – DC operated normally open contact opening delay ms 12 – 15 - 25 – DC operated with auxiliary contact module, max. closing delay ms – – 70 70 Notes 1) Smoothed DC, three-phase bridge rectifier or smoothed two-phase bridge rectifier AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 95 1.1 Contactors Amplifier modules, electronic timer module, contactor monitoring device 1 ETS-VS3, DILM, CMD General Standards ETS4-VS3 DILM32-XTE CMD(24VDC) CMD(220-240VAC) IEC/EN 60947, VDE 0660, UL, CSA DIN EN 61812, IEC/EN 60947, VDE 0660, UL, CSA IEC/EN 60947 UL CSA Lifespan, mechanical AC operated c (contacts) x 10 6 – 3 10 DC operated c (contacts) x 10 6 30 3 3 c (contacts) x 10 6 72000 – 9000 Maximum operating frequency DC operated Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Storage Open °C °C – -25 - 60 -40 - 80 -25 - 60 -40 - 80 -25 - 50 Enclosed Mounting position °C -25 - 45 Any -25 - 40 As required, except suspended – Any g 10 – – N/O g – 6 4 NC g – 6 4 Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 20 ms N/O Half-sinusoidal shock 10 ms Protection type IP20 IP20 Finger- and back-of-hand proof IP20 kg 0.09 0.08 0.1 Solid mm² Flexible with ferrule mm² 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1) 1 x (0.75 - 2.5) 2 x (0.75 - 1.5) 1) 1 x (0.75 - 2.5) 2 x (0.75 - 1.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 1 x (0.75…2.5) 2 x (0.75…1.5) 1 x (0.75…1.5) 2 x (0.75…1.5) Solid or stranded AWG Protection against direct contact when actuated from front (EN 50274) Weight Terminal capacity Terminal screw 16 - 14 18 - 14 18…14 M3.5 M3.5 M3.5 Pozidriv screwdriver Size 2 2 2 Flat-blade screwdriver mm 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 Max. tightening torque Nm 1.2 1.2 1.2 1) Notes 96 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Use equal cross-sections only Contactors Amplifier modules, electronic timer module, contactor monitoring device 1.1 ETS-VS3, DILM, CMD 1 ETS4-VS3 DILM32-XTE CMD(24VDC) CMD(220-240VAC) Contacts Rated impulse withstand voltage U imp V AC Overvoltage category/degree of pollution 6000 6000 8000 4000 III/2 III/3 III/3 III/3 Rated insulation voltage Ui V AC 440 600 100 250 Rated operating voltage Ue V 440 AC 400 AC 24 DC 250 AC 220/240 V Ie A 2 3 – – 280/415 V Ie A 2 – – – – Rated operational current AC-15 DC-13 1) DC-13 L/R 15 ms Contacts in series: DC-13 L/R 1 24 V A 2.6 1 – 1 60 V A 1 0.2 – – 1 110 V A 0.6 0.2 – – 1 220 V A 0.2 0.1 – – 50 ms Contacts in series: DC-13 L/R 1 24 V A 2 1 – – 1 60 V A 0.6 0.2 – – 1 110 V A 0.08 0.2 – – 1 220 V A 0.08 0.1 – – 300 ms Contacts in series: 1 24 V A 0.6 1 – – 1 60 V A 0.2 0.2 – – 1 110 V A 0.08 0.2 – – 1 220 V A 0.03 0.1 – – V AC – 250 – – V AC – <10 -8 , < one failure in 100 million operations 250 – – – – – Safe isolation according to EN 61140 Between coil and auxiliary contacts Between the auxiliary contacts Control circuit reliability (at Ue = 24 V DC, U min = 17 V, I min = 5.4 mA) Fault probability Conventional thermal current I th A 6 4 – – Switch operations Switch operations x 10 6 7 – – – x 10 6 1 – – – Component lifespan AC-15 230 V, I e = 0.1 A 230 V, I e = 1.2 A Short-circuit rating without welding Short-circuit protection rating maximum fuse 2) Notes 500 V A gG/gL – 4 2 2 500 V A fast 4 – – – 1) 2) Switch-on and switch-off conditions based on DC-13, time constant as specified See transparent overlay "Fuses" for time/current characteristics (please enquire) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 97 1.1 Contactors Amplifier modules, electronic timer module, contactor monitoring device 1 ETS-VS3, DILM, CMD ETS4-VS3 DILM32-XTE CMD(24VDC) CMD(220-240VAC) Magnet systems Voltage tolerance Starting voltage AC operated Pick-up x Uc – 0.85 - 1.1 0.85 - 1.1 Pick-up x Uc 0.85 - 1.2 0.7 - 1.2 0.85 - 1.1 AC operated Sealing VA – 2 4 AC operated Sealing W – 1.8 4 DC operated Pick-up = sealing W 0.6 – 4 Duty factor % DF 100 100 100 Changeover times at 100 % Uc (recommended values) DC operated closing delay DC operated opening delay ms ms 7 3 – – – – Max. operating frequency Ops/h – 3600 – 6 A/250 V Ops/h – 360 – On-delayed ms – < 50 – Off-delayed ms – < 200 – % – <5 – ms – 70 – – DC operated 1) Power consumption Maximum operating frequency Minimum on duration Repetition accuracy (with constant parameters) Deviation Recovery time (after 100% time delay) Contact changeover time DILM32-XTEE11/DILM32-XTED11 tu ms – 10 DILM32-XTEY20 tu ms – 50 – CMD tu ms – – 100 ± 20% 1) Notes 98 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Smoothed DC, three-phase bridge rectifier or smoothed two-phase bridge rectifier 1.1 Mini contactor relays DILEEM, DILEM 1 DILEEM DILEM DILEM12 DILEEM-G DILEM-G DILEM12-G DILEM4 DILEM4-G General Standards IEC/EN 60947, VDE 0660, CSA, UL Lifespan, mechanical; Coil 50/60 Hz at 50 Hz Lifespan, mechanical c (contacts) 7 – 7 – x 10 6 10 20 20 – Ops/h 9000 Maximum operating frequency Mechanical Electrical (Contactor without overload relay) Characteristic curves Page 91 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open °C -25 - 50 Enclosed °C -25 - 40 Mounting position Any, except for vertically with terminals A1/A2 below A1 A2 Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 ms Basic device without auxiliary contact module Main circuit normally open contact Auxiliary contacts NC/Normally open contact Basic devices with auxiliary contact module Main circuit normally open contact Auxiliary contacts Normally open contact/NC g 10 g 10/8 g 10 g 20/20 Protection type Protection against direct contact when actuated from front (EN 50274) Weight Terminal capacity: main and auxiliary contacts 10/8 – – 0.2 0.17 IP20 Finger- and back-of-hand proof kg 0.2 Solid mm² Flexible with ferrule mm² 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) Solid or stranded AWG Terminal screw 0.17 18 - 14 M3.5 Pozidriv screwdriver Size 2 Flat-blade screwdriver mm Max. tightening torque Nm 0.8 x 5.5 1x6 1.2 Terminal capacity springloaded terminals main and control circuits Solid mm² Flexible with ferrule mm² Flat-blade screwdriver mm 1 x (1 - 2.5) 2 x (1 - 2.5) 1 x (1 - 2.5) 2 x (1 - 2.5) 0.6 x 3.5 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 99 1.1 Mini contactor relays DILEEM, DILEM 1 DILEEM DILEEM-G DILEM DILEM-G DILEM4 DILEM4-G DILEM12 DILEM12-G V AC 6000 6000 6000 6000 6000 V AC V AC III/3 690 690 III/3 690 690 III/3 690 690 III/3 690 690 III/3 690 690 Safe isolation according to EN 61140 Between coil and contacts Between the contacts V AC V AC 300 300 300 300 300 300 300 300 300 300 Making capacity of up to 440 V (cos as specified in IEC/EN 60947) Breaking 220/230 V capacity 380/400 V A A A 110 90 90 110 90 90 110 90 90 110 90 90 120 96 96 A A 64 42 64 42 64 42 72 42 Main contacts Rated impulse withstand voltage U imp Overvoltage category/pollution degree Rated insulation voltage Rated operating voltage Devices lifespan Ui Ue 500 V 660/690 V AC-1 AC-3 64 42 Engineering Page 88 Engineering Page 87 AC-4 Short-circuit protection rating maximum fuse Type “2” coordination 500 V Type “1” coordination 500 V Engineering Page 87 gL/gG gL/gG A A 10 20 10 20 10 20 10 20 20 35 I th I th I th I th A A A 22 20 19 22 20 19 22 20 19 22 20 19 22 20 19 A 16 16 16 16 16 I th I th A A 50 40 50 40 60 50 60 50 50 40 220/230 V Ie A 6.6 9 9 9 12 240 V 380/400 V 415 V 440 V Ie Ie Ie Ie A A A A 6.6 6.6 6.6 6.6 9 9 9 9 9 9 9 9 9 9 9 9 12 12 12 10.5 500 V 660/690 V 220/230 V 240 V 380/400 V Ie Ie P P P A A kW kW kW 5 3.5 1.5 1.8 3 6.4 4.8 2.2 2.5 4 6.4 4.8 2.2 2.5 4 6.4 4.8 2.2 2.5 4 9 5.2 3.5 3 5.5 415 V P kW 3.1 4.3 4.3 4.3 5.5 440 V 500 V 660/690 V P P P kW kW kW 3.3 3 3 4.6 4 4 4.6 4 4 4.6 4 4 5.5 5.5 4 220/230 V Ie A 5 6.6 6.6 6.6 6.6 240 V 280/400 V 415 V 440 V 500 V 660/690 V Ie Ie Ie Ie Ie Ie A A A A A A 5 5 5 5 3.7 2.9 6.6 6.6 6.6 6.6 5 3.4 6.6 6.6 6.6 6.6 5 3.4 6.6 6.6 6.6 6.6 5 3.4 6.6 6.6 6.6 6.6 5 3.4 220/230 V 240 V 380/400 V 415 V 440 V 500 V P P P P P P kW kW kW kW kW kW 1.1 1.3 2.2 2.3 2.4 2.2 1.5 1.8 3 3.1 3.3 3 1.5 1.8 3 3.1 3.3 3 1.5 1.8 3 3.1 3.3 3 1.5 1.8 3 3.1 3.3 2.2 660/690 V P kW 2.2 3 3 3 2.2 AC voltage AC-1 operation Conventional thermal current 3 pole 50 - 60 Hz Open Enclosed 1) Conventional thermal current, 1-pole Open 1) Enclosed 1) AC-3 operation Rated operational current AC-3 open, 50 - 60 Hz, 3-pole1) Motor rating AC-4 operation Rated operational current AC-4 open, 50 - 60 Hz, 3-pole1) Rated operational power Notes 100 at 40 °C at 50 °C at 55 °C 1) At maximum permissible ambient air temperature AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Mini contactor relays 1.1 DILEEM, DILEM 1 DILEEM DC voltage Operations Rated operational current open DC-1 DC-3 DC-5 DILEM12 DILEM12 -G 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 110 V Ie A 20 20 20 20 20 20 20 20 220 V 12 V 24 V 60 V 110 V Ie Ie Ie Ie Ie A A A A A 20 6 6 3 2 20 6 6 3 2 20 8 8 4 3 20 8 8 4 3 20 8 8 4 3 20 8 8 4 3 20 8 6 4 3 20 8 8 4 3 220 V 12 V 24 V Ie Ie Ie A A A – 1.8 1.8 – 1.8 1.8 – 2.5 2.5 – 2.5 2.5 1 2.5 2.5 1 2.5 2.5 – 2.5 2.5 – 2.5 2.5 60 V Ie A 1.8 1.8 2.5 2.5 2.5 2.5 2.5 2.5 Ie Ie A A 1.8 0.2 1.8 0.2 1.5 0.3 1.5 0.3 2.5 1 2.5 1 1.5 0.3 1.5 0.3 W 2 3.5 2 3.5 2.7 4.7 2 3.5 W 0.5 0.7 0.5 0.7 – – 0.5 0.7 Pick-up x Uc 0.8 - 1.1 – 0.8 - 1.1 – 0.8 - 1.1 – 0.8 - 1.1 – Pick-up x Uc 0.8 - 1.1 – – 0.85 - 1.1 – 0.8 - 1.1 – Pick-up x Uc – 0.8 - 1.1 0.85 1.1 – 0.8 - 1.1 – 0.85 - 1.1 – 0.8 - 1.1 Pick-up Pick-up Sealing VA W VA 25 22 4.6 – – – 25 22 4.6 – – – 25 22 4.6 – – – 25 22 4.6 – – – Sealing Pick-up Pick-up W VA W 1.3 30 26 – – – 1.3 30 26 – – – 1.3 30 26 – – – 1.3 30 26 – – – Sealing VA Sealing Pick-up W VA 5.4 1.6 29 – – – 5.4 1.6 29 – – – 5.4 1.6 29 – – – 5.4 1.6 29 – – – Pick-up Sealing Sealing Pick-up W VA W VA 24 3.9 1.1 25 – – – – 24 3.9 1.1 25 – – – – 24 3.9 1.1 25 – – – – 24 3.9 1.1 25 – – – – Pick-up VA 30 – 30 – 30 – 30 – Pick-up VA VA/W 29 – – 2.6 29 – – 2.6 29 – – 2.6 29 – – 2.6 % DF 100 100 100 100 100 100 100 100 ms ms 14 21 26 35 14 21 26 35 14 21 26 35 14 21 26 35 ms ms ms 8 18 Max. 45 15 25 Max. 70 8 18 Max. 45 15 25 Max. 70 8 18 Max. 45 15 25 Max. 70 8 18 Max. 45 15 25 Max. 70 Single-voltage coil, 50 Hz, and dualvoltage coil, 50 Hz, 60 Hz Dual-frequency coil 50/60 Hz at 60 Hz Single-voltage coil, 50 Hz, and dualvoltage coil, 50 Hz, 60 Hz Dual-frequency coil 50/60 Hz at 50 Hz Dual-frequency coil 50/60 Hz at 60 Hz Power consumption pick-up = sealing Duty fac tor Switching times at 100 % Uc N/O Closing delay min. Closing delay max. Opening delay min. Opening delay max. Closing delay with top mounting auxiliary contact Changeover time at 110 % U c tactors Changeover time min. Notes DILEM4G A A A Dual-frequency coil 50/60 Hz at 50 Hz Coil DILEM4 Ie Ie Ie DC operated Power consumption Reversing con- DILEMG 12 V 24 V 60 V At Ie to AC-3/400 V Magnet systems Voltage tolerance Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Dual-frequency coil 50/60 Hz DC operation1) DILEM Engineering Page 92 110 V 220 V Current heat loss (3-pole or 4-pole) At Ith AC operation DILEEMG Changeover time maX. Arcing time at 690 V AC Lifespan, mechanical; Coil 50/60 Hz c (contacts) ms 16 40 16 40 16 40 16 40 ms ms x 10 6 21 Max. 12 7 50 Max. 12 – 21 Max. 12 7 50 Max. 12 – 21 Max. 12 7 50 Max. 12 – 21 Max. 12 7 50 Max. 12 – 1) Smoothed DC or three-phase bridge rectifier AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 101 1.1 Mini contactor relays DILEEM, DILEM 1 Auxiliary contact Interlocked opposing contacts to EN 60947-5-1 Annex L, including auxiliary contact module Rated impulse withstand voltage U imp V AC Overvoltage category/pollution degree DILE(E)M(-12)... …DILEM Yes Yes 6000 6000 III/3 III/3 Rated insulation voltage Ui V AC 690 690 Rated operating voltage Ue V AC 600 600 Between coil and auxiliary contacts V AC 300 300 Between the auxiliary contacts V AC 300 300 Safe isolation according to EN 61140 Rated operational current AC-15 220/240 V Ie A 6 4 380/415 V Ie A 3 2 500 V Ie A 1.5 1.5 1 24 V A 2.5 2.5 2 60 V A 2.5 2.5 3 100 V A 1.5 1.5 3 220 V A 0.5 0.5 Conventional thermal current I th A 10 10 Control circuit reliability (at U e = 24 V DC, U min = 17 V, I min = 5.4 mA) Fault probability DC L/R 15 ms Contacts in series: <10 --8 , < one failure in 100 million operations Component lifespan at U e = 240 V AC-15 c (contacts) x 10 6 0.2 0.2 c (contacts) x 10 6 0.15 0.15 PKZM0-4 PKZM0-4 DC 1) L/R = 50 ms: 2 contacts in series at I e = 0.5 A Short-circuit rating without welding Maximum overcurrent protective device Short-circuit protection rating maximum fuse 500 V A gG/gL 6 6 500 V A fast 10 10 0.2 0.2 Current heat loss at load of I th Per contact W 1) Notes 102 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Switch-on and switch-off conditions based on DC-13, time constant as specified 1.1 Contactors Basic devices up to 170 A DILM7 ... DILM170 DILM7 1 General Standards Lifespan, mechanical AC operated DC operated Operating frequency, mechanical DILM9 DILM12 DILM15 DILM17 DILM25 IEC/EN 60947, VDE 0660, UL, CSA c (contacts) c (contacts) Mechanical, AC operated DC operated Maximum operating frequency Electrical (Contactor without overload relay) x 10 6 x 10 6 Operations/h Operations/h 10 10 10 10 10 10 10 10 10 10 10 10 9000 9000 9000 9000 9000 9000 5000 5000 5000 5000 5000 5000 Characteristic curves Page 74 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open Enclosed Storage Mounting position AC- and DC operated °C °C -25…60 -25…40 -25…60 -25…40 -25…60 -25…40 -25…60 -25…40 -25…60 -25…40 -25…60 -25…40 °C -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 90 180° ° 90 90 ° ° 30° Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 ms Main contacts N/O Auxiliary contacts g 10 10 10 10 10 10 N/O NC g g 7 5 7 5 7 5 7 5 7 5 7 5 N/O Auxiliary contacts g 5.7 5.7 5.7 5.7 6.9 6.9 N/O NC g g 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 5.3 3.5 5.3 3.5 IP20 IP20 IP20 Finger- and back-of-hand proof IP20 IP00 IP00 kg kg 0.23 0.28 0.23 0.28 0.42 0.48 0.42 0.48 mm² – – 1 x (0.75 - 16) 2 x (0.75 - 10) 1 x (0.75 - 16) 2 x (0.75 - 10) 1 x 16 1 x 16 18 - 10 – 18 - 10 – 18 - 6 – Mechanical shock resistance (IEC/EN 60068-2-27) with table mounting Half-sinusoidal shock 10 ms Main contacts Protection type Protection against direct contact when actuated from front (EN 50274) Weight AC operated DC operated Terminal type, screw connection Terminal capacity of main cable Solid 0.23 0.28 Flexible with ferrule mm² Stranded mm² 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1) – – AWG mm 18 - 10 – Solid mm² Flexible with ferrule mm² 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) Solid or stranded AWG Solid or stranded Flat conductor Number of layers x width x thickness 18 - 10 – 0.23 0.28 18 - 6 – Terminal capacity of control circuit cable Notes 104 18 - 10 1) 18 - 10 Also without ferrule. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 18 - 10 1x (0.75 - 2.5) 2x (0.75 - 2.5) 18 - 10 1 x (0.75 - 4) 2 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 18 - 14 1.1 Contactors Basic devices up to 170 A DILM32 DILM38 DILM40 DILM50 DILM65 DILM72 DILM80 DILM95 DILM115 DILM150 DILM170 1 IEC/EN 60947, VDE 0660, UL, CSA 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 3600 3600 3600 3600 3600 3600 3600 3600 3000 3000 -25…60 -25…40 -25…60 -25…40 -25…60 -25…40 -25…60 -25…40 -25…60 -25…40 -25…60 -25…40 -25…60 -25…40 -25…60 -25…40 -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 Characteristic curves Page 74 Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 -25…60 -25…40 -25…60 -25…40 -25…60 -25…40 -40 - 80 -40 - 80 -40 - 80 90 180° ° 90 90 ° ° 30° 10 10 10 10 10 10 10 10 10 10 10 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 6.9 6.9 10 10 10 10 10 10 10 10 10 5.3 3.5 5.3 3.5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 IP00 IP00 Finger- and back-of-hand proof IP00 IP00 IP00 IP00 IP00 IP00 IP00 IP00 IP00 0.42 0.48 0.9 1.1 0.9 1.1 0.9 1.1 0.9 1.1 2 2.1 2 2.1 2 2.1 2 2.1 2 2.1 – – – – – 8…3/0 8…3/0 8…3/0 18 - 14 18 - 14 18 - 14 0.42 0.48 1 x (0.75 - 16) 2 x (0.75 - 10) 1 x (0.75 - 16) 2 x (0.75 - 10) 1 x 16 1 x 16 18 - 6 – 18 - 6 – 1 x (0.75 - 16) 2 x (0.75 - 16) 1 x (0.75 - 35) 2 x (0.75 - 25) 1 x (16 - 50) 2 x (16 - 35) 12 - 2 12 - 2 2 x (6 x 9 x 0.8) 18 - 14 18 - 14 12 - 2 12 - 2 18 - 14 18 - 14 1 x (10 - 95) 2 x (10 - 70) 1 x (16 - 95) 2 x (16 - 70) 8…3/0 8…3/0 2 x (6 x 16 x 0.8) 1 x (0.75 - 4) 2 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 18 - 14 18 - 14 18 - 14 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 105 1.1 Contactors Basic devices up to 170 A 1 DILM7 ... DILM170 General Main cable connection screw/bolt Tightening torque Control circuit cable connection screw/bolt Tightening torque Tools Main conductors Pozidriv screwdriver Internal hexagon Flat-blade screwdriver Nm Nm SW Size mm mm DILM7 DILM9 DILM12 DILM15 DILM17 DILM25 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M5 3.2 M3.5 1.2 M5 3.2 M3.5 1.2 2 – 0.8 x 5.5 1x6 2 – 0.8 x 5.5 1x6 2 – 0.8 x 5.5 1x6 2 – 0.8 x 5.5 1x6 2 – 0.8 x 5.5 1x6 2 – 0.8 x 5.5 1x6 Auxiliary conductors Pozidriv screwdriver Size 2 2 2 2 2 2 Flat-blade screwdriver mm 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 mm² 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) – – – – 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 18 - 14 – – – – – – – – 18 - 14 18 - 14 Terminal type spring-cage terminal Terminal capacity of main cable Solid Flexible mm² Flexible with ferrule mm² Flexible without ferrule mm² Solid or stranded Terminal capacity of control circuit cable Solid AWG 18 - 14 mm² 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) Flexible mm² 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) Flexible with ferrule mm² Flexible without ferrule mm² 18 - 14 18 - 14 Solid or stranded Tools Strip length AWG 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 18 - 14 mm 10 10 10 10 10 10 Screwdriver blade width Main contacts Rated impulse withstand voltage Overvoltage category/pollution degree Rated insulation voltage Rated operating voltage Safe isolation according to EN 61140 Between coil and contacts mm 3.5 3.5 3.5 3.5 3.5 3.5 U imp V AC Ui Ue V AC V AC 8000 III/3 690 690 8000 III/3 690 690 8000 III/3 690 690 8000 III/3 690 690 8000 III/3 690 690 8000 III/3 690 690 V AC 400 400 400 400 440 440 V AC A 400 112 400 112 400 144 400 155 440 238 440 350 A A 70 70 90 90 120 120 124 124 170 170 250 250 A A 50 40 70 50 100 70 100 70 170 120 250 150 gG/gL 500 V A 20 20 20 20 35 35 gG/gL 690 V A 16 16 20 20 35 35 gG/gL 500 V gG/gL 690 V A A 35 20 35 20 35 25 63 50 63 50 100 50 Between the contacts Making capacity (cos to IEC/EN 60947) Breaking capacity To 690 V 230 V 280/400 V 500 V 660/690 V Short-circuit rating Short-circuit protection rating maximum fuse Type “2” coordination 400 V 690 V Type “1” coordination 400 V 690 V 106 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 18 - 14 1.1 Contactors Basic devices up to 170 A 1 DILM32 DILM38 DILM40 DILM50 DILM65 DILM72 DILM80 DILM95 DILM115 DILM150 DILM170 M5 3.2 M3.5 1.2 M5 3.2 M3.5 1.2 M6 3.3 M3.5 1.2 M6 3.3 M3.5 1.2 M6 3.3 M3.5 1.2 M6 3.3 M3.5 1.2 M10 14 M3.5 1.2 M10 14 M3.5 1.2 M10 14 M3.5 1.2 M10 14 M3.5 1.2 M10 14 M3.5 1.2 2 – 0.8 x 5.5 1x6 2 – 0.8 x 5.5 1x6 2 – 0.8 x 5.5 1x6 2 – 0.8 x 5.5 1x6 2 – 0.8 x 5.5 1x6 2 – 0.8 x 5.5 1x6 – 5 – – 5 – – 5 – – 5 – – 5 – 2 2 2 2 2 2 2 2 2 2 2 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 18 - 14 18 - 14 18 - 14 18 - 14 18 - 14 18 - 14 18 - 14 18 - 14 18 - 14 18 - 14 18 - 14 10 10 10 10 10 10 10 10 10 10 10 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 8000 III/3 690 690 8000 III/3 690 690 8000 III/3 690 690 8000 III/3 690 690 8000 III/3 690 690 8000 III/3 690 690 8000 III/3 690 690 8000 III/3 690 690 8000 III/3 690 690 8000 III/3 690 690 8000 III/3 690 690 440 440 440 440 440 440 690 690 690 690 690 440 384 440 384 440 560 440 700 440 910 440 910 690 1120 690 1330 690 1610 690 2100 690 2100 320 320 320 320 400 400 500 500 650 650 650 650 800 800 950 950 1150 1150 1500 1500 1500 1500 320 180 320 180 400 250 500 320 650 370 650 370 800 650 950 800 1150 1100 1500 1200 1500 1320 63 63 63 80 125 125 160 160 250 250 250 35 35 50 63 80 80 160 160 250 250 250 125 63 125 63 125 80 160 80 250 100 250 100 250 200 250 200 250 250 250 250 250 250 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 107 1.1 Contactors Basic devices up to 170 A 1 DILM7 ... DILM170 DILM7 AC voltage AC-1 operation Conventional free air thermal current 3 pole 50 - 60 Hz Conventional free air thermal current 1 pole Open DILM9 DILM12 DILM15 DILM17 DILM25 at 50 °C I th A 22 22 22 22 40 45 at 50 °C I th A 21 21 21 21 38 43 at 55 °C at 60 °C I th I th A A 21 20 21 20 21 20 21 20 37 35 42 40 Enclosed I th A 18 18 18 18 32 36 Open I th A 50 50 50 50 88 100 Enclosed I th A 45 45 45 45 80 90 220/230 V Ie A 7 9 12 15.5 18 25 240 V Ie A 7 9 12 15.5 18 25 380/400 V Ie A 7 9 12 15.5 18 25 415 V Ie A 7 9 12 15.5 18 25 440 V Ie A 7 9 12 15.5 18 25 500 V Ie A 5 7 10 12.5 18 25 660/690 V 220/230 V Ie P A kW 4 2.2 5 2.5 7 3.5 9 4 12 5 15 7.5 240 V P kW 2.2 3 4 4.6 5.5 8.5 380/400 V P kW 3 4 5.5 7.5 7.5 11 415 V P kW 4 5.5 7 8 10 14.5 440 V P kW 4.5 5.5 7.5 8.4 10.5 15.5 500 V P kW 3.5 4.5 7 7.5 12 17.5 660/690 V P kW 3.5 4.5 6.5 7 11 14 220/230 V Ie A 5 6 7 7 10 13 240 V Ie A 5 6 7 7 10 13 380/400 V Ie A 5 6 7 7 10 13 415 V Ie A 5 6 7 7 10 13 440 V 500 V Ie Ie A A 5 4.5 6 5 7 6 7 6 10 10 13 13 660/690 V 220/230 V Ie P A kW 4 1 4.5 1.5 5 2 5 2 8 2.5 10 3.5 240 V P kW 1.5 1.6 2.2 2.2 3 4 380/400 V P kW 2.2 2.5 3 3 4.5 6 415 V P kW 2.3 2.8 3.4 3.4 5 6.5 440 V P kW 2.4 3 3.6 3.6 5.5 7 500 V P kW 2.5 2.8 3.5 3.5 6 8 660/690 V P kW 2.9 3.6 4.4 4.4 6.5 8.5 AC-3 operation Rated operational current AC -3 open, 50 – 60 Hz, 3 pole Rated operational power AC-4 operation Rated operational current AC-4 open, 50 - 60 Hz, 3 pole Rated operational powe DC voltage Switching of DC current Page 92 Operations Rated operational current I e open DC-1 operation DC-3 operation DC-5 operation 108 60 V Ie A 20 20 20 20 35 40 110 V Ie A 20 20 20 20 35 40 220 V 440 V Ie Ie A A 15 1 15 1.3 15 1.3 15 1.3 35 2.9 40 2.9 660 V Ie A 20 20 20 20 35 35 110 V Ie A 20 20 20 20 35 35 220 V Ie A 1.5 1.5 1.5 1.5 10 10 440 V Ie A 0.2 0.2 0.2 0.2 0.6 0.6 60 V Ie A 20 20 20 20 35 35 110 V Ie A 20 20 20 20 35 35 220 V Ie A 1.5 1.5 1.5 1.5 10 10 440 V Ie A 0.2 0.2 0.2 0.2 0.6 0.6 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Basic devices up to 170 A 1 DILM32 DILM38 DILM40 DILM50 DILM65 DILM72 DILM80 DILM95 DILM115 DILM150 DILM170 45 45 60 80 98 98 110 130 160 190 225 43 43 57 71 88 88 98 125 142 180 200 42 40 42 40 55 50 68 65 83 80 83 80 94 90 115 110 135 130 170 160 190 185 36 36 45 58 72 72 80 100 115 144 166 100 100 125 162 200 200 225 275 325 400 460 90 90 112 145 180 180 200 250 285 360 415 32 38 40 50 65 72 80 95 115 150 170 32 38 40 50 65 72 80 95 115 150 170 32 38 40 50 65 72 80 95 115 150 170 32 38 40 50 65 72 80 95 115 150 170 32 38 40 50 65 72 80 95 115 150 170 32 38 40 50 65 72 80 95 115 150 170 18 10 22.5 11 25 12.5 32 15.5 37 20 37 22 65 25 80 30 93 37 100 48 150 52 11 12 13.5 17 22 25 27.5 32 40 52 57 15 18.5 18.5 22 30 37 37 45 55 75 90 19 20 24 30 39 41 48 57 70 91 100 20 21 25 32 41 44 51 60 75 95 105 23 24 28 36 47 50 58 70 85 110 120 17 21 23 30 35 35 63 75 90 96 140 15 15 18 21 25 25 40 50 55 65 65 15 15 18 21 25 25 40 50 55 65 65 15 15 18 21 25 25 40 50 55 65 65 15 15 18 21 25 25 40 50 55 65 65 15 15 15 15 18 18 21 21 25 25 25 25 40 40 50 50 55 55 65 65 65 65 12 4 12 4 14 5 17 6 20 7 20 7 27 12 37 16 45 17 50 20 50 20 4.5 4.5 5.5 6.5 7.5 7.5 13 17 19 22 22 7 7 9 10 12 12 20 26 28 33 33 7.5 7.5 9.5 11 13 13 24 30 33 39 39 8 8 10 12 14 14 25 32 35 41 41 9 9 11 13 16 16 29 36 40 47 47 10 10 12 14 17 17 26 35 43 48 48 40 40 50 60 72 72 110 110 160 160 160 40 40 50 50 72 72 110 110 160 160 160 40 2.9 40 2.9 45 2.9 45 2.9 65 2.9 65 2.9 70 4.5 70 4.5 90 4.5 90 4.5 90 4.5 40 40 50 60 72 72 110 110 160 160 160 40 40 50 50 72 72 110 110 160 160 160 25 25 25 25 35 35 35 35 40 40 40 0.6 0.6 0.6 0.6 0.6 0.6 1 1 1 1 1 40 40 50 60 72 72 110 110 160 160 160 40 40 50 50 72 72 110 110 160 160 160 10 10 25 25 35 35 35 35 40 40 40 0.6 0.6 0.6 0.6 0.6 0.6 1 1 1 1 1 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 109 1.1 Contactors Basic devices up to 170 A 1 DILM7 ... DILM170 Current heat loss (3 pole) Current heat loss at I th DILM7 DILM9 DILM12 DILM15 DILM17 DILM25 W 3 3 3 3 7.3 9.6 W mȍ 0.37 2.5 0.6 2.5 1.1 2.5 1.8 2.5 1.9 2 3.8 2 Pick-up Drop-out x Uc x Uc 0.8 - 1.1 0.3 - 0.6 0.8 - 1.1 0.3 - 0.6 0.8 - 1.1 0.3 - 0.6 0.8 - 1.1 0.3 - 0.6 0.8 - 1.1 0.3 - 0.6 0.8 - 1.1 0.3 - 0.6 Pick-up Drop-out x Uc x Uc 0.8 - 1.1 0.15 - 0.6 0.8 - 1.1 1) 0.15 - 0.6 0.8 - 1.1 1) 0.15 - 0.6 0.8 - 1.1 1) 0.15 - 0.6 0.7 - 1.2 2) 0.15 - 0.6 0.7 - 1.2 2) 0.15 - 0.6 52 Current heat loss at Ie to AC-3/400 V Impedance per pole Magnet systems Voltage tolerance AC operated AC operated DC operated 3) DC operated 3) Power consumption of the coil in a cold state and 1.0 x Uc 50 Hz Pick-up VA 24 24 24 24 52 50 Hz Sealing VA 3.4 3.4 3.4 3.4 7.1 7.1 50 Hz Sealing W 1.2 1.2 1.2 1.2 2.1 2.1 60 Hz 60 Hz Pick-up Sealing VA VA 30 4.4 30 4.4 30 4.4 30 4.4 67 8.7 67 8.7 60 Hz 50/60 Hz Sealing Pick-up W VA 50/60 Hz Sealing VA 50/60 Hz Sealing W 1.4 27 25 4.2 3.3 1.4 1.2 3 1.4 27 25 4.2 3.3 1.4 1.2 3 1.4 27 25 4.2 3.3 1.4 1.2 4.5 1.4 27 25 4.2 3.3 1.4 1.2 4.5 2.6 62 58 9.1 6.5 2.5 2 12 2.6 62 58 9.1 6.5 2.5 2 12 DC operated Pick-up W DC operated Sealing W 3 3 4.5 4.5 0.5 0.5 % DF 100 100 100 100 100 100 15…21 9…18 15…21 9…18 15…21 9…18 15…21 9…18 16…22 8…14 16…22 8…14 Duty factor Changeover times at 100 % Uc (recommended values) Main contacts AC operated Closing delay Opening delay ms ms DC operated Closing delay ms 31 31 31 31 47 47 Opening delay ms 12 12 12 12 30 30 ms mA 10 – 10 – 10 – 10 – 10 – 10 – Arcing time Permissible residual current when A1 - A2 are actuated from the electronic system (with 0 signal) Lifespan, mechanical; Coil 50/60 Hz At 50 Hz Mechanical lifespan at 50 Hz approx. 30% lower than under Technical data general Electromagnetic compatibility (EMC) Emitted interference To EN 60947-1 Interference immunity To EN 60947-1 Notes 1) At 24 V DC: 0.7 – 1.3 without auxiliary contact 2) RDC 24 (Umin 24 V DC/Umax 27 V DC) module and at ambient temperature + 40 °C RDC 60 (Umin 48 V DC/Umax 60 V DC) RDC 130 (Umin 110 V DC/Umax 130 V DC) RDC 240 (Umin 200 V DC/Umax 240 V DC) Example: Uc = 0.7 x Umin - 1.2 x Umax / Uc = 0.7 x 24 V - 1.2 x 27 V DC 3) At least: smoothed two-phase bridge rectifier or three-phase rectifier 110 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Basic devices up to 170 A 1 DILM32 DILM38 DILM40 DILM50 DILM65 DILM72 DILM80 DILM95 DILM115 DILM150 DILM170 12.1 12.1 11.3 19 28.8 28.8 12.2 18.2 20.3 30.7 41.1 6.1 2 6.1 2 7.2 1.5 11.3 1.5 19 1.5 23 1.5 9.6 0.5 13.5 0.5 15.9 0.4 27 0.4 34.7 0.4 0.8 - 1.1 0.3 - 0.6 0.8 - 1.1 0.3 - 0.6 0.8 - 1.1 0.3 - 0.6 0.8 - 1.1 0.3 - 0.6 0.8 - 1.1 0.3 - 0.6 0.8 - 1.1 0.3 - 0.6 0.8 - 1.1 0.3 - 0.6 0.8 - 1.1 0.3 - 0.6 0.8 - 1.15 0.25 - 0.6 0.8 - 1.15 0.25 - 0.6 0.8 - 1.15 0.25 - 0.6 0.7 - 1.2 2) 0.15 - 0.6 0.7 - 1.2 2) 0.15 - 0.6 0.7 - 1.2 2) 0.15 - 0.6 0.7 - 1.2 2) 0.15 - 0.6 0.7 - 1.2 2) 0.15 - 0.6 0.7 - 1.2 2) 0.15 - 0.6 0.7 - 1.2 2) 0.15 - 0.6 0.7 - 1.2 2) 0.15 - 0.6 0.7 - 1.2 2) 0.15 - 0.6 0.7 - 1.2 2) 0.15 - 0.6 0.7 - 1.2 2) 0.15 - 0.6 52 52 149 149 149 149 310 310 180 180 180 7.1 7.1 16 16 16 16 26 26 3.1 3.1 3.1 2.1 2.1 4.3 4.3 4.3 4.3 5.8 5.8 2.1 2.1 2.1 67 8.7 67 8.7 178 19 178 19 178 19 178 19 345 30 345 30 170 3.1 170 3.1 170 3.1 2.6 62 58 9.1 6.5 2.6 62 58 9.1 6.5 5.3 168 154 22 14 5.3 168 154 22 14 5.3 168 154 22 14 5.3 168 154 22 14 7.1 372 328 37.1 22.6 7.1 372 328 37.1 22.6 2.1 170 170 3.1 3.1 2.1 170 170 3.1 3.1 2.1 170 170 3.1 3.1 2.5 2 12 2.5 2 12 5.3 4.3 24 5.3 4.3 24 5.3 4.3 24 5.3 4.3 24 7.5 6.1 90 7.5 6.1 90 2.1 2.1 149 2.1 2.1 149 2.1 2.1 149 0.5 0.5 0.5 0.5 0.5 0.5 1.3 1.3 2.1 2.1 2.1 100 100 100 100 100 100 100 100 100 100 100 16…22 8…14 16…22 8…14 12…18 8…13 12…18 8…13 12…18 8…13 12…18 8…13 14…20 9…14 14…20 9…14 28…33 35…41 28…33 35…41 28…33 35…41 47 47 54 54 54 54 45 45 35 35 35 30 30 24 24 24 24 34 34 30 30 30 10 – 10 – 10 – 10 – 10 – 10 – 15 15 15 15 Mechanical lifespan at 50 Hz approx. 30% lower than under 1 1 15 1 1 Technical data general To EN 60947-1 To EN 60947-1 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 111 1.1 Contactors Comfort devices and standard devices greater than 170 A 1 DILM185...DILM1600, DILH Contactors DILM185A DILM225A DILM250 DILM300A DILM400 DILM500 DILM570 General Standards Lifespan, mechanical IEC/EN 60947, VDE 0660, UL, CSA AC operated c (contacts) x 10 6 10 10 10 10 7 7 7 DC operated c (contacts) x 10 6 10 10 10 10 7 7 7 3000 3000 3000 3000 3000 3000 3000 3000 2000 2000 2000 2000 2000 2000 Operating frequency, mechanical AC operated DC operated Operations/h Operations/h Maximum operating frequency Electrical (Contactor without overload relay) Climatic proofing Engineering Page 91 Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open °C -25…60 -25…60 -25…60 -25…60 -25…60 -25…60 -25…60 Enc losed °C -25…40 -25…40 -25…40 -25…40 -25…40 -25…40 -25…40 °C -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 10 10 10 30° 30° 180° ° 90 90 ° Storage Mounting position: AC and DC-actuated Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 ms Main contacts N/O Auxiliary contacts g N/O g 10 10 10 10 10 10 10 NC g 8 8 8 8 8 8 8 IP00 IP00 IP00 IP00 IP00 Finger- and back-of-hand proof with cover or terminal block IP00 IP00 kg 3.2 3.2 6.5 6.5 8 8 8 Flexible with cable lug mm² 50 - 185 50 - 185 50 - 240 50 - 240 50 - 240 50 - 240 50 - 240 Stranded with cable lug mm² 50 - 185 70 - 185 70 - 240 70 - 240 70 - 240 70 - 240 70 - 240 Solid or stranded AWG 1/0 - 350 MCM 32 2/0 - 250 MCM 32 2/0 - 500 MCM 25 2/0 - 500 MCM 25 2/0 - 500 MCM 25 2/0 - 500 MCM 30 2/0 - 500 MCM 30 Protection type Protection against direct contact when actuated from front (EN 90274) Weight Weight Terminal capacity of main cable Busbar Width mm Main cable connection screw/bolt 10 10 10 10 M10 M10 M10 M10 M10 M10 M10 Nm 24 24 24 24 24 24 24 Solid mm² Flexible with ferrule mm² Solid or stranded AWG 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (18 - 12) 2 x (18 - 12) 2 x (18 - 12) 2 x (18 - 12) 2 x (18 - 12) 2 x (18 - 12) 2 x (18 - 12) Nm M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 mm 16 16 16 16 16 16 16 Size 2 2 2 2 2 2 2 Tightening torque Terminal capacity of control circuit cable Control circuit cable connection screw/bolt Tightening torque Tools Main conductors Wrench Auxiliary conductors Pozidriv screwdriver 112 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Comfort devices and standard devices greater than 170 A 1 DILM580 DILM650 DILM750 DILM820 DILM1000 DILM1600 DILH1400 DILH2000 DILH2200 DILH2600 IEC/EN 60947, VDE 0660, UL, CSA 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Engineering Page 91 Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 -25…60 -25…60 -25…60 -25…60 -25…60 -25…60 -25…60 -25…60 -25…60 -25…60 -25…40 -25…40 -25…40 -25…40 -25…40 -25…40 -25…40 -25…40 -25…40 -25…40 -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 -40 - 80 ° 90 ° 90 30° 30° 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 8 8 8 8 8 8 8 8 8 8 IP00 IP00 IP00 IP00 Finger- and back-of-hand proof with cover or terminal block IP00 IP00 IP00 IP00 IP00 IP00 15 15 15 15 15 32 15 32 32 32 50 - 240 50 - 240 50 - 240 50 - 240 50 - 240 – – – – – 70 - 240 70 - 240 70 - 240 70 - 240 70 - 240 – – – – – 2/0 - 500 MCM 2/0 - 500 MCM 2/0 - 500 MCM 2/0 - 500 MCM 2/0 - 500 MCM – – – – – 50 50 60 60 60 100 80 100 100 100 M10 M10 M12 M12 M12 M12 M12 M12 M12 M12 24 24 35 35 35 35 35 35 35 35 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (18 - 12) 2 x (18 - 12) 2 x (18 - 12) 2 x (18 - 12) 2 x (18 - 12) 2 x (18…12) 2 x (18 - 12) 2 x (18 - 12) 2 x (18 - 12) 2 x (18 - 12) M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 16 16 18 18 18 18 18 18 18 18 2 2 2 2 2 2 2 2 2 2 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 113 1.1 Contactors Comfort devices and standard devices greater than 170 A 1 DILM185...DILM1600, DILH Contactors Main contacts Rated impulse withstand voltage Overvoltage category/pollution degree Rated insulation voltage Rated operating voltage Safe isolation according to EN 61140 Between coil and contacts Between the contacts Making capacity (cos to IEC/EN 60947) Breaking capacity 220/230 V DILM185A DILM225A DILM250 DILM300A DILM400 DILM500 DILM570 U imp V AC 8000 III/3 8000 III/3 8000 III/3 8000 III/3 8000 III/3 8000 III/3 8000 III/3 Ui Ue V AC V AC 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 V AC V AC A 500 500 2700 500 500 2700 500 500 3000 500 500 3600 500 500 5500 500 500 5500 500 500 6000 A 2250 2250 2500 3000 5000 5000 5800 A A A A 2250 2250 2250 760 Page 87 2250 2250 2250 760 2500 2500 2500 760 3000 3000 3000 950 5000 5000 5000 950 5000 5000 5000 950 5800 5800 5800 950 gG/gL 500 V gG/gL 690 V gG/gL 1000 V A A A 250 250 160 250 250 160 315 315 160 315 315 160 500 500 200 500 500 200 500 500 200 gG/gL 500 V gG/gL 690 V gG/gL 1000 V A A A 400 315 200 400 315 200 400 400 200 400 400 200 630 630 250 630 630 250 800 630 250 I th A 337 356 400 430 612 857 920 I th I th I th I th A A A A 301 287 275 245 310 295 285 275 360 340 330 300 385 365 350 315 548 522 500 450 767 731 700 650 821 783 750 – A A 685 625 707 636 825 742 875 785 1250 1125 1750 1600 1875 – 380/440 V 500 V 660/690 V 1000 V Component lifespan Short-circuit rating Short-circuit protection rating maximum fuse Type “2” coordination 400 V 690 V 1000 V Type “1” coordination 400 V 690 V 1000 V AC voltage AC-1 operation Conventional thermal current 3 pole 50 - 60 Hz Open at 40 °C at 50 °C at 55 °C at 60 °C Enclosed 1) Conventional thermal current, 1-pole Open1) I th I th Enclosed 1) AC-3 operation Rated operational current AC -3 open, 50 – 60 Hz, 3 pole 220/230 V 240 V 380/400 V Ie Ie Ie A A A 185 185 185 225 225 225 250 250 250 300 300 300 400 400 400 500 500 500 580 580 580 415 V 440 V 500 V Ie Ie Ie A A A 185 185 185 225 225 225 250 250 250 300 300 300 400 400 400 500 500 500 580 580 500 Ie Ie A A 150 76 160 76 250 76 210 95 360 95 360 95 360 95 220/230 V P kW 55 70 75 90 125 155 185 240 V 380/400 V 415 V P P P kW kW kW 62 90 110 75 110 132 85 132 148 100 160 180 132 200 240 170 250 300 200 315 348 440 V 500 V 660/690 V 1000 V P P P P kW kW kW kW 115 132 140 108 138 160 150 108 132 180 240 108 185 215 195 132 200 290 344 132 250 360 344 132 370 360 344 132 660/690 V 1000 V Rated operational power Notes 1) 2) 114 At maximum permissible ambient air temperature To 690 V AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Comfort devices and standard devices greater than 170 A 1 DILM580 DILM650 DILM750 DILM820 DILM1000 DILM1600 DILH1400 DILH2000 DILH2200 DILH2600 8000 III/3 8000 III/3 8000 III/3 8000 III/3 8000 III/3 8000 III/3 8000 III/3 8000 III/3 8000 III/3 8000 III/3 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 500 500 7800 500 500 7800 500 500 9840 500 500 9840 500 500 9840 500 500 19000 500 500 9840 500 500 9840 500 500 9840 500 500 9840 6500 6500 8200 8200 8200 16000 8200 8200 8200 8200 6500 6500 6500 4350 Page 87 6500 6500 6500 4350 8200 8200 8200 5800 8200 8200 8200 5800 8200 8200 8200 5800 16000 16000 16000 5800 8200 8200 8200 5800 8200 8200 8200 5800 8200 8200 8200 5800 8200 8200 8200 5800 630 630 500 630 630 500 630 630 630 630 630 630 630 630 630 – – – – – – – – – – – – – – – 1000 1000 630 1000 1000 630 1200 1200 800 1200 1200 800 1200 1200 800 – – – – – – – – – – – – – – – 980 1041 1102 1225 1225 2200 2) 1714 2) 2450 2) 2700 2) 3185 2) 876 836 800 – 931 888 850 – 986 940 900 – 1095 1044 1000 – 1095 1044 1000 – 1970 2) 1880 2) 1800 2) – 1533 2) 1462 2) 1400 2) – 2190 2) 2089 2) 2000 2) – 2400 2) 2300 2) 2200 2) – 2847 2) 2716 2) 2600 2) – 2000 – 2125 – 2250 – 2500 – 2500 – 4500 – 3500 – 5000 – 5500 – 6500 2) – 580 580 580 650 650 650 750 750 750 820 820 820 1000 1000 1000 1600 1600 1600 – – – – – – – – – – – – 580 580 580 650 650 650 750 750 750 820 820 820 1000 1000 1000 1600 1600 1600 – – – – – – – – – – – – 580 435 650 435 750 580 820 580 1000 750 1600 1200 – – – – – – – – 185 205 240 260 315 500 – – – – 200 315 348 225 355 390 260 400 455 285 450 500 340 560 610 550 900 930 – – – – – – – – – – – – 370 420 560 600 420 470 630 600 480 550 720 800 450 600 750 800 650 730 1000 1100 1000 1180 1600 1770 – – – – – – – – – – – – – – – – AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 115 1.1 Contactors Comfort devices and standard devices greater than 170 A 1 DILM185...DILM1600, DILH Contactors DILM185A DILM225A DILM250 DILM300A DILM400 DILM500 DILM570 AC voltage AC-4 operation Rated operational current AC -4 open, 50 – 60 Hz, 3 pole 220/230 V 240 V Ie Ie A A 136 136 164 164 200 200 240 240 296 296 360 360 360 360 380/400 V Ie A 136 164 200 240 296 360 360 415 V Ie A 136 164 200 240 296 360 360 440 V Ie A 136 164 200 240 296 360 360 500 V Ie A 136 164 200 240 296 360 360 660/690 V 1000 V Ie Ie A A 110 55 120 55 200 76 170 76 296 95 296 95 296 95 220/230 V 240 V P P kW kW 41 45 51 54 62 68 75 82 92 101 112 122 112 122 380/400 V P kW 75 90 110 132 160 200 200 415 V P kW 80 96 117 142 176 216 216 440 V P kW 85 102 125 150 186 229 229 500 V 660/690 V P P kW kW 96 102 116 110 143 189 172 160 214 283 260 344 260 344 1000 V P kW 77 77 108 109 132 132 132 Rated operational power Capacitor operation Individual compensation rated operational current I e of alternating current capacitor Open To 525 V A 220 220 220 307 307 307 307 690 V A 133 133 133 177 177 177 177 x Ie x 10 6 30 0.1 30 0.1 30 0.1 30 0.1 30 0.1 30 0.1 30 0.1 Ops/h 200 200 200 200 200 200 200 Max. peak inrush current Component lifespan c (contacts) Max. operating frequency DC voltage Operations Engineering Page 92 Rated operational current I e open DC-1 operation 60 V Ie A 300 300 300 400 400 400 400 110 V Ie A 300 300 300 400 400 400 400 220 V 440 V Ie Ie A A 300 11 300 11 300 11 400 11 400 11 400 11 400 11 60 V Ie A 300 300 300 400 400 400 400 110 V Ie A 300 300 300 400 400 400 400 220 V DC-5 operation Ie A 300 300 300 400 400 400 400 60 V Ie A 300 300 300 400 400 400 400 110 V Ie A 300 300 300 400 400 400 400 Ie A 300 300 300 400 400 400 400 Current heat loss at Ith W 34 45 55 37 58 113 130 Current heat loss at Ie to AC-3/400 V W 16 23 28 21 37 58 78 DC-3 operation 220 V Current heat loss (3 pole) 116 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Comfort devices and standard devices greater than 170 A 1 DILM580 DILM650 DILM750 DILM820 DILM1000 DILM1600 DILH1400 DILH2000 DILH2200 DILH2600 456 456 512 512 576 576 656 656 800 800 1280 1280 – – – – – – – – 456 512 576 656 800 1280 – – – – 456 512 576 656 800 1280 – – – – 456 512 576 656 800 1280 – – – – 456 512 576 656 800 1280 – – – – 456 348 512 348 576 464 656 464 800 700 1280 1120 – – – – – – – – 143 156 161 176 181 200 209 228 260 280 430 450 – – – – – – – – 250 280 315 355 450 750 – – – – 274 307 346 394 490 770 – – – – 290 326 367 418 520 830 – – – – 330 440 370 494 417 556 474 633 590 780 940 1300 – – – – – – – – 509 509 678 678 1000 1650 – – – – 463 463 463 463 463 – – – – – 265 265 265 265 265 – – – – – 30 0.1 30 0.1 30 0.1 30 0.1 30 0.1 – – – – – – – – – – 200 200 200 200 200 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 61 69 78 96 96 155 188 192 232 250 32 41 54 65 96 123 – – – – – AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 117 1.1 Contactors Comfort devices and standard devices greater than 170 A DILM185...DILM1600, DILH Contactors 1 Magnet systems Voltage tolerance 1) AC operated AC operated DC operated Power consumption of the coil in a cold state and 1.0 x Uc DC operated 50/60 Hz 50/60 Hz 50/60 Hz DC operated DC operated Comfort series DILM… Standard range DILM…-S Comfort series DILM… Standard range DILM…-S Voltage tolerance Power consumption of the coil in a cold state and 1.0 x Uc Comfort series DILM… Comfort series DILM… Comfort series DILM… Comfort series DILM… Standard range DILM…-S Standard range DILM…-S Standard range DILM…-S Standard range DILM…-S (0 - 0.2 x Uc min ) DILM225A DILM250 Excess voltage Pick-up phase Notes DILM570 – – – – – – – – – – – – – – – 0.8 - 1.15 0.25 - 0.6 0.7 - 1.2 0.15 - 0.6 210 2.6 2.6 180 2.1 – – – – – – – – – – – 0.7 x U c min - 1.15 x U c max Pick-up x Uc – – 0.85 x U c min - 1.1 x U c max Drop-out x Uc – – 0.2 x U c min - 0.6 x U c min Drop-out x Uc – – 0.2 x U c min - 0.4 x U c min Pick-up VA – – 380 2) 380 2) 450 2) 450 2) 450 2) Pick-up W – – 250 250 350 350 350 Sealing VA – – 4.3 4.3 4.3 4.3 4.3 Sealing W – – 3.3 3.3 3.3 3.3 3.3 Pick-up VA – – 360 4) 360 4) 715 4) 715 4) 715 4) Pick-up W – – 325 625 645 645 645 Sealing VA – – 4.3 4.3 4.3 4.3 4.3 Sealing W – – 3.3 3.3 3.3 3.3 3.3 % DF – – 100 100 100 100 100 ms ms ms ms – – < 60 < 40 – – < 60 < 40 < 100 < 110 < 55 < 40 < 80 < 110 < 55 < 40 < 80 < 110 < 55 < 50 < 80 < 110 < 55 < 50 < 80 < 110 < 55 < 50 – – Targeted bridging during this time Drop-out of the contactor Targeted bridging during this time Drop-out of the contactor Contactor remains switched on Contactor remains switched on Contactor remains switched on Drop-out of the contactor Contactor does not switch on Contactor switches on safely Contactor switches on safely mȍ – – 500 500 500 500 – mA – – 1 1 1 1 – V V 15 5 15 5 15 5 15 5 15 5 15 5 – – (0 - 0.2 x Uc min ) 12 ms (0.2 - 0.6 x U c min ) > 12 ms (0.6 - 0.7 x U c min ) (1.15 - 1.3 x Uc max ) (> 1.3 x U c max ) 3 s (> 1.3 x U c max ) > 3 s (0.7 x Uc min ) (0.7 x U c min - 1.15 x U c max ) (> 1.15 x U c max ) This product is designed for operation in industrial environments (environment 2). The use in residential environments (environment 1) could cause electrical interference so that addition suppression must be planned. 1) Uc min, Uc max, Control transformer with u k 0.6 3) Control transformer with u k 0.7 4) u k 10 % 2) 118 DILM500 0.8 - 1.15 0.25 - 0.6 0.7 - 1.2 0.15 - 0.6 210 2.6 2.6 180 2.1 – 10 ms Permissible transitional contact resistance (of external control unit when A11 is actuated) Permissible residual current ( when A11 is actuated from the electronic system in the event of a 0 signal) PLC signal level (A3 - A4) to IEC/EN 61131-2 (part no. 2) H ig h Low Electromagnetic compatibility (EMC) Electromagnetic compatibility DILM400 x Uc x Uc x Uc x Uc VA VA W W W x Uc (0 - 0.2 x U c min ) > 10 ms Voltage drops DILM300A Pick-up Drop-out Pick-up Drop-out Pick-up Sealing Sealing Pick-up Sealing Pick-up D u ty fa c to r Changeover time at 100 % U c (recommended values), main circuit Closing delay Comfort series DILM… Opening delay Standard range Closing delay DILM…-S Opening delay Behavior in limit range and transition area, hold state Voltage interruption DILM185A AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Comfort devices and standard devices greater than 170 A DILM580 DILM650 – – – – – – – – – – 0.7 x U c min - 1.15 x U c max DILM750 DILM820 DILM1000 DILM1600 DILH1400 DILH2000 DILH2200 DILH2600 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 1 0.85 x U c min - 1.1 x U c max 0.2 x U c min - 0.6 x U c min 0.2 x U c min - 0.4 x U c min 800 3) 800 3) 800 3) 800 3) 800 3) 1600 3) 800 3) 1600 3) 1600 3) – 700 700 700 700 700 1400 700 1400 1400 – 7.5 7.5 7.5 7.5 7.5 15 7.5 15 15 – 6.5 6.5 6.5 6.5 6.5 13 6.5 13 13 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 100 100 100 100 100 100 100 100 100 100 < 70 < 110 – – < 70 < 110 – – < 70 < 110 – – < 70 < 110 – – < 70 < 110 – – < 70 < 40 – – < 70 < 40 – – < 70 < 40 – – < 70 < 40 – – – – – – Targeted bridging during this time Drop-out of the contactor Targeted bridging during this time Drop-out of the contactor Contactor remains switched on Contactor remains switched on Contactor remains switched on Drop-out of the contactor Contactor does not switch on Contactor switches on safely Contactor switches on safely 15 5 500 500 500 500 500 500 500 500 500 500 1 1 1 1 1 1 1 1 1 1 15 5 15 5 15 5 15 5 15 5 15 5 15 5 15 5 15 5 This product is designed for operation in industrial environments (environment 2). The use in residential environments (environment 1) could cause electrical interference so that addition suppression must be planned. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 119 1.1 Contactors Basic devices up to 200 A, 4 pole DILMP20 ... DILMP200 DILMP20 1 DILMP32 DILMP63 DILMP125 DILMP45 DILMP80 DILMP160 DILMP200 General Standards Lifespan, mechanical AC operated DC operated Operating frequency, mechanical Mechanical, AC operated DC operated Maximum operating frequency Electrical (Contactor without overload relay) Climatic proofing IEC/EN 60947, VDE 0660, UL, CSA c (contacts) c (contacts) x 10 6 x 10 6 Operations/h Operations/h 10 10 5000 5000 3600 3600 600 Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature °C °C °C -25…60 -25…40 -40 - 80 90 90 ° Open Enclosed Storage Mounting position AC- and DC operated 30° 180° ° 30° Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 ms Main contacts N/O Auxiliary contacts N/O NC Protection type With accessories Protection against direct contact when actuated from front (EN 50274) Terminal type, screw connection Terminal capacity of main cable Solid g 10 g g 7 5 IP20 IP00 – IP20 Finger- and back-of-hand proof mm² 1 x (0.75 - 16) 2 x (0.75 - 10) 1 x (0.75 - 16) 2 x (0.75 - 10) 1 x 16 Flexible with ferrule mm² Stranded mm² 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) – AWG mm 18 - 14 – 18 - 6 – mm² Nm 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 M3.5 1.2 M3.5 1.2 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 M5 3 M3.5 1.2 1 x (0.75 - 4) 2 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 M6 3.3 M3.5 1.2 1 x (0.75 - 4) 2 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 M10 14 M3.5 1.2 Size mm 2 – 2 – 2 – – 5 mm 0.8 x 5.5 1x6 0.8 x 5.5 1x6 0.8 x 5.5 1x6 – Size mm 2 0.8 x 5.5 1x6 2 0.8 x 5.5 1x6 2 0.8 x 5.5 1x6 2 0.8 x 5.5 1x6 Solid or stranded Flat conductor Number of layers x width x thickness Terminal capacity of control circuit cable Solid Flexible with ferrule mm² Solid or stranded Main cable connection screw/bolt Tightening torque Control circuit cable connection screw/bolt Tightening torque Tools Main conductors Pozidriv screwdriver Internal hexagon Flat-blade screwdriver AWG Nm SW 1 x (2.5 - 16) 2 x (2.5 - 16) 1 x (2.5 - 35) 2 x (2.5 - 25) 1 x (16 - 50) 2 x (16 - 35) 12 - 2 2x (6 x 9 x 0.8) – 1 x (10 - 95) 2 x (10 - 70) 1 x (16 - 120) 2 x (16 - 95) 8 - 250MCM 2x (6 x 16 x 0.8) Auxiliary conductors Pozidriv screwdriver Flat-blade screwdriver 120 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Basic devices up to 200 A, 4 pole DILMP20 ... DILMP200 DILMP20 DILMP32 DILMP63 DILMP125 DILMP45 DILMP80 DILMP160 1 DILMP200 Main contacts Rated impulse withstand voltage Overvoltage category/pollution degree Rated insulation voltage Rated operating voltage Safe isolation according to EN 61140 Between coil and contacts Between the contacts Making capacity (cos to IEC/EN 60947) Breaking capacity 220/230 V 380/400 V 500 V 660/690 V Short-circuit rating Short-circuit protection rating maximum fuse Type “2” coordination 400 V 690 V Type “1” coordination 400 V 690 V AC voltage AC-1 operation Conventional thermal current 3 pole 50 - 60 Hz Open at 40 °C at 50 °C at 60 °C Enclosed Conventional thermal current, 1 pole Open Enclosed Rated operational power 220/230 V 240 V 380 V 415 V 440 V 500 V 690 V AC-3 operation Rated operational current AC -3 open, 50 – 60 Hz, 3 pole 220/230 V 240 V 380/400 V 415 V 440 V 500 V 660/690 V Rated operational power 220/230 V 240 V 380/400 V 415 V 440 V 500 V 660/690 V U imp V AC Ui Ue V AC V AC 8000 III/3 690 690 To 690 V V AC V AC A 400 400 144 440 440 238 350 560 700 1120 1330 1800 A A 120 120 180 180 250 250 400 400 500 500 800 800 950 950 1150 1150 A A 100 70 180 120 250 144 400 250 500 296 800 650 950 750 1150 800 gG/gL 500 V gG/gL 690 V A A 20 20 35 35 35 35 63 50 80 63 160 160 160 160 250 200 gG/gL 500 V gG/gL 690 V A A 35 25 63 50 100 50 125 80 160 80 250 200 250 200 250 200 I th I th I th I th A A A A 22 21 20 18 32 30 28 27 45 41 39 36 63 60 54 50 80 76 69 64 125 116 108 100 160 150 138 128 200 188 172 160 I th I th A A 60 54 84 76 117 105 162 146 207 186 325 292 415 373 516 464 P P P P P P P kW kW kW kW kW kW kW 8 9 14 15 16 18 24 12 13 20 22 23 26 35 16 18 28 31 33 37 49 23 25 39 43 46 52 68 29 32 50 55 58 66 87 45 49 78 85 90 103 136 58 63 100 109 116 132 174 72 79 125 137 145 165 217 Ie Ie Ie Ie Ie Ie Ie A A A A A A A 12 12 12 12 12 10 7 18 18 18 18 18 18 12 25 25 25 25 25 25 15 40 40 40 40 40 40 25 50 50 50 50 50 50 32 80 80 80 80 80 80 65 95 95 95 95 95 95 80 115 115 115 115 115 115 93 P P P P P P P kW kW kW kW kW kW kW 3.5 4 5.5 7 7.5 7 6.5 5 5.5 7.5 10 10.5 12 11 7.5 8.5 11 14.5 15.5 17.5 14 12.5 13.5 18.5 24 25 28 23 15.5 17 22 30 32 36 30 25 27.5 37 48 51 58 63 30 33 45 57 60 70 75 37 40 55 70 75 85 90 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 121 1.1 Contactors Basic devices up to 200 A, 4 pole 1 DILMP20 ... DILMP200 DILMP20 DILMP32 DILMP63 DILMP45 DILMP125 DILMP80 DILMP160 DILMP200 DC voltage Rated operational current I e open DC-1 operation 60 V Ie A 22 32 45 63 80 125 160 200 110 V Ie A 22 32 45 63 80 125 160 200 220 V Ie A 6 32 45 63 80 125 160 200 440 V DC-3 operation Ie A 1.3 3 3 5 5 10 10 10 200 60 V Ie A 20 32 45 63 80 125 160 110 V Ie A 20 32 45 63 80 125 160 200 220 V Ie A 1.5 32 45 63 80 125 160 200 440 V DC-5 operation Ie A 0.2 6 6 8 8 9 9 9 60 V Ie A 20 32 45 63 80 125 160 200 110 V 220 V Ie Ie A A 20 1.5 25 15 32 22 50 38 80 70 125 100 160 125 200 150 440 V Ie A 0.2 4 4 8 8 8 8 8 W mȍ 4.7 2.5 8.2 2 12 1.5 16 1 23 0.7 29 0.6 46 0.6 60 0.5 x Uc 0.8 - 1.1 0.8 - 1.1 0.8 - 1.1 x Uc 0.8 - 1.1 0.85 - 1.1 0.85 - 1.1 0.8 - 1.1 Drop-out Pick-up x Uc x Uc 0.4 - 0.6 0.8 - 1.1 0.4 - 0.6 0.7 - 1.2 0.4 - 0.6 0.7 - 1.2 0.4 - 0.6 0.7 - 1.2 Drop-out x Uc 0.2 - 0.6 0.2 - 0.6 0.2 - 0.6 0.2 - 0.6 AC operated 50/60 Hz Pick-up VA 24 50 150 180 AC operated 50/60 Hz Pick-up W 19 40 95 150 AC operated 50/60 Hz Sealing VA 4 8 16 3.1 AC operated 50/60 Hz DC operated 1) Sealing Pick-up W W 1.2 4.5 2.4 12 4 24 2.1 149 DC operated 1) Sealing W 4.5 0.5 0.5 2.1 % DF 100 100 100 100 Current heat loss (3 pole) Current heat loss at I th Impedance per pole Magnet systems Voltage tolerance AC operated 50 Hz Pick-up AC operated 50/60 Hz AC operated DC operated 1) DC operated 1) Power consumption of the coil in a cold state and 1.0 x U c Duty factor Changeover times at 100 % Uc (recommended values) 0.8 - 1.1 Main contacts AC operated Closing delay ms 15…21 16…22 12…18 28…33 Opening delay ms 9…18 8…14 8…13 35…41 Closing delay ms 31 47 54 35 Opening delay ms 12 30 24 30 ms 10 DC operated 1) Arcing time Permissible residual current when A1 - A2 are actuated from the electronic system (with 0 signal) Notes 122 mA 10 1 1) 10 1 At least double-pulse bridge rectifier AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 15 1 1 1.1 Contactors Contactor for capacitors DILK 1 DILK12 General Standards Ambient temperature DILK20 DILK25 DILK33 DILK50 -25…60 -25…40 -25…60 -25…40 -25…60 -25…40 IEC/EN 60947, VDE 0660 Open Enclosed °C °C -25…60 -25…40 -25…60 -25…40 Mounting position 30° 30° ° 180° ° 90 90 90 ° 30° Protection type IP00 Protection against direct contact when actuated from front (EN 50274) Finger- and back-of-hand proof IP00 IP00 IP00 IP00 Weight basic device AC operated kg 0.55 0.55 0.55 1 1 Solid mm² 1 x (0.75 - 16) 1 x (0.75 - 16) 1 x (0.75 - 16) 1 x (2.5 - 16) 1 x (2.5 - 16) Flexible with ferrule mm² 1 x (0.75 - 16) 1 x (0.75 - 16) 1 x (0.75 - 16) 1 x (2.5 - 35) 1 x (2.5 - 35) Stranded Solid or stranded mm² AWG 1 x 16 18 - 16 1 x 16 18 - 6 1 x 16 18 - 6 1 x (16 - 50) 12 - 2 1 x (16 - 50) 12 - 2 mm - - - 1 x (6 x 9 x 0.8) 1 x (6 x 9 x 0.8) 230 V kvar 7.5 11 15 20 25 400 V kvar 12.5 20 25 33.3 50 525 V kvar 16.7 25 33.3 40 65 690 V kvar 20 33.3 40 55 85 Terminal capacity of main cable Flat conductor Number of layers x width x thickness Group compensation 60 Hz 50/60 Hz Open 230 V Ie A 18 29 38 50 72 400 V Ie A 18 29 38 50 72 525 V Ie A 18 29 38 50 72 690 V Ie A 18 29 38 50 72 230 V Ie A 16 26 34 45 65 400 V Ie A 16 26 34 45 65 525 V Ie A 16 26 34 45 65 690 V Ie A 16 26 34 45 65 x Ie 180 180 180 180 180 x 10 6 0.15 0.15 0.15 0.15 0.15 Ops/h 120 120 120 120 120 Enclosed Making capacity (i-peak value) without damping Component lifespan Maximum operating frequency c (contacts) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 123 1.1 Contactors Contactor for capacitors 1 DILK DILK12 DILK20 DILK25 DILK33 DILK50 Magnet systems Voltage tolerance AC operated AC operated Power consumption of the coil in a cold state and 1.0 x U c Pick-up x Uc 0.8 - 1.1 0.8 - 1.1 0.8 - 1.1 0.8 - 1.15 0.8 - 1.15 Drop-out x Uc 0.3 - 0.6 0.3 - 0.6 0.3 - 0.6 0.3 - 0.6 0.3 - 0.6 50 Hz Pick-up VA 58 58 58 45 45 50 Hz 50 Hz Sealing Sealing VA W 7.6 2.3 7.6 2.3 7.6 2.3 1.5 1.5 1.5 1.5 60 Hz Pick-up VA 71 71 71 45 45 60 Hz 60 Hz 50/60 Hz Sealing Sealing Pick-up VA W VA 50/60 Hz Sealing VA 50/60 Hz Sealing W 9.3 2.8 65 59 9.6 7 2.7 2.2 100 9.3 2.8 65 59 9.6 7 2.7 2.2 100 9.3 2.8 65 59 9.6 7 2.7 2.2 100 1.5 1.5 45 45 1.5 1.5 1.5 1.5 100 1.5 1.5 45 45 1.5 1.5 1.5 1.5 100 Duty factor Changeover times at 100 % Uc (recommended values) Main contacts % DF AC operated Closing delay ms 16…22 16…22 16…22 50 50 Opening delay ms 8…14 8…14 8…14 40 40 Arcing time Electromagnetic compatibility (EMC) ms 10 10 10 10 10 Emitted interference To EN 60947-1 To EN 60947-1 To EN 60947-1 To EN 60947-1 To EN 60947-1 Interference immunity Further technical data To EN 60947-1 To EN 60947-1 To EN 60947-1 To EN 60947-1 To EN 60947-1 M17 M25 M32 M50 M65 As per contactor 124 DIL AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Contactors Illumination contactors 1.1 DILL 1 DILL12 General Standards Lifespan, mechanical AC operated Operating frequency, mechanical Mechanical, AC operated Maximum operating frequency Electrical DILL20 IEC/EN 60947, VDE 0660, UL, CSA c (contacts) x 10 6 Operations/h Operations/h Climatic proofing Ambient temperature DILL18 Open Enclosed Storage °C °C °C 1 1 1 60 60 60 60 60 60 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30 -25…60 -25…60 -25…40 -25…40 -40 - 80 -40 - 80 -25…60 -25…40 -40 - 80 Mounting position 30° 90 90 ° 30° 180° ° Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 ms 6.9 6.9 6.9 IP00 IP00 IP00 kg 0.42 0.42 0.42 U imp V AC Ui Ue V AC V AC A A 8000 III/3 690 690 238 170 10000 8000 III/3 690 690 350 250 10000 8000 III/3 690 690 550 320 10000 Protection type Weight AC operated Main contacts Rated impulse withstand voltage Overvoltage category/pollution degree Rated insulation voltage Rated operating voltage Making capacity Breaking capacity Lifespan, electrical Short-circuit protection rating maximum fuse 400 V AC voltage AC-1 operation Conventional thermal current at 40 °C at 60 °C 230 V 400 V AC-1 operation 220/230 V 400 V Electric lamps Filament bulbs Mercury blended lamps Fluorescent lamp load Conventional reactor starter connection Duo circuit Electronic upstream devices High-pressure mercury vapour lamps Metal-halide lamps High-pressure sodium lamps Low-pressure sodium lamps Maximum permissible compensation capacitance Further technical data As per contactor 380/400 V c (contacts) gG/gL 500 V A 63 100 125 I th I th Ie Ie A A A A 27 24 12 12 40 35 18 18 45 40 20 20 Ie Ie A A 14 14 21 21 27 27 A A 14 12 21 16 27 23 A A A A A A A μF 20 20 12 12 12 12 7.5 470 26 26 18 18 18 18 10 470 35 35 20 20 20 20 12 470 M17 M25 M32 DIL AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 125 1.1 Contactors Contactors up to 150 A with electronic actuation 1 DILMF DILMF8 DILMF11 General Mounting position DILMF14 30° 180° ° 90 90 ° 30° DILMF17 AC voltage AC-3 operation Rated operational current AC -3 open, 50 – 60 Hz, 3 pole Rated operational power 220/230 V 240 VI 380/400 V 415 V 440 V 500 V 660/690 V 220/230 V 240 V 380/400 V 415 V 440 V 500 V 660/690 V Ie Ie Ie Ie Ie Ie Ie P P P P P P P A A A A A A A kW kW kW kW kW kW kW 7 7 7 7 7 5 4 2.2 2.2 3 4 4.5 3.5 3.5 9 9 9 9 9 7 5 2.5 3 4 5.5 5.5 4.5 4.5 12 12 12 12 12 10 7 3.5 4 5.5 7 7.5 7 6.5 18 18 18 18 18 18 12 5 5.5 7.5 10 10.5 12 11 220/230 VI 240 V 380/400 V 415 V 440 V 500 V 660/690 V 220/230 V 240 V 380/400 V 415 V 440 V 500 V 660/690 V Ie Ie Ie Ie Ie Ie Ie P P P P P P P A A A A A A A kW kW kW kW kW kW kW 5 5 5 5 5 4.5 4 1 1.5 2.2 2.3 2.4 2.5 2.9 6 6 6 6 6 5 4.5 1.5 1.6 2.5 2.8 3 2.8 3.6 7 7 7 7 7 6 5 2 2.2 3 3.4 3.6 3.5 4.4 10 10 10 10 10 10 8 2.5 3 4.5 5 5.5 6 6.5 W W 2.4 0.3 2.4 0.6 2.4 1 7.3 1.9 x Uc x Uc VA VA W % DF ms ms 0.8 - 1.15 0.2 - 0.5 14 0.7 0.7 100 40 45 SEMI F47 0.8 - 1.15 0.2 - 0.5 14 0.7 0.7 100 40 45 SEMI F47 0.8 - 1.15 0.2 - 0.5 14 0.7 0.7 100 40 45 SEMI F47 0.8 - 1.15 0.2 - 0.5 14 0.7 0.7 100 40 45 SEMI F47 AC-4 operation Rated operational current AC-4 open, 50 - 60 Hz, 3 pole Rated operational power Current heat loss (3 pole) Current heat loss at Ith Current heat loss at Ie to AC-3/400 V Magnet systems Voltage tolerance AC operated AC operated Electronic actuation Power consumption of the coil in a cold state Electronic actuation and 1.0 x U c Electronic actuation Duty factor Closing delay Switching times Opening delay suitable according to Electromagnetic compatibility (EMC) Emitted interference Interference immunity Further technical data As per contactor Terminal type As per contactor 126 Pick-up Drop-out Pick-up Sealing Sealing To EN 60947-1 To EN 60947-1 DIL M7 M9 M12 M17 DIL M17 M17 M17 M17 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Contactors up to 150 A with electronic actuation 1 DILMF25 DILMF32 DILMF40 DILMF65 DILMF80 DILMF95 DILMF115 DILMF150 30° 180° ° 90 90 ° 30° DILMF50 25 25 25 25 25 25 15 7.5 8.5 11 14.5 15.5 17.5 14 32 32 32 32 32 32 18 10 11 15 19 20 23 17 40 40 40 40 40 40 25 12.5 13.5 18.5 24 25 28 23 50 50 50 50 50 50 32 15.5 17 22 30 32 36 30 65 65 65 65 65 65 37 20 22 30 39 41 47 35 80 80 80 80 80 80 65 25 27.5 37 48 51 58 63 95 95 95 95 95 95 80 30 4 45 57 60 70 75 115 115 115 115 115 115 93 37 40 55 70 75 85 90 150 150 150 150 150 150 100 48 52 75 91 95 110 96 13 13 13 13 13 13 10 3.5 4 6 6.5 7 8 8.5 15 15 15 15 15 15 12 4 4.5 7 7.5 8 9 10 18 18 18 18 18 18 14 5 5.5 9 9.5 10 11 12 21 21 21 21 21 21 17 6 6.5 10 11 12 13 14 25 25 25 25 25 25 20 7 7.5 12 13 14 16 17 40 40 40 40 40 40 27 12 13 20 24 25 29 26 50 50 50 50 50 50 37 16 17 26 30 32 36 35 55 55 55 55 55 55 45 17 19 28 33 35 40 43 65 65 65 65 65 65 50 20 22 33 39 41 47 48 9.6 3.8 12.1 6.1 11.3 7.2 19 11.3 28.8 19 14.6 11.5 21.8 16.2 30.4 23.8 46.1 40.5 0.8 - 1.15 0.2 - 0.5 14 0.7 0.7 100 40 45 SEMI F47 0.8 - 1.15 0.2 - 0.5 14 0.7 0.7 100 40 45 SEMI F47 0.8 - 1.15 0.2 - 0.5 45 1.5 1.5 100 50 45 SEMI F47 0.8 - 1.15 0.2 - 0.5 45 1.5 1.5 100 50 45 SEMI F47 0.8 - 1.15 0.2 - 0.5 45 1.5 1.5 100 50 45 SEMI F47 0.8 - 1.15 0.2 - 0.5 75 2 2 100 55 40 SEMI F47 0.8 - 1.15 0.2 - 0.5 75 2 2 100 55 40 SEMI F47 0.8 - 1.15 0.2 - 0.5 180 3.1 2.1 100 40 40 SEMI F47 0.8 - 1.15 0.2 - 0.5 180 3.1 2.1 100 40 40 SEMI F47 M25 M32 M40 M50 M65 M80 M95 M115 M150 M25 M32 M40 M50 M65 M80 M95 M115 M150 To EN 60947-1 To EN 60947-1 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 127 1.1 Contactors Auxiliary contact modules 1 DILM..., DILA... Auxiliary contact Interlocked opposing contacts within an auxiliary contact module (to IEC 60947-5-1 Annex L) 1) Normally closed (not late-normally closed) suitable as a mirror contact (to IEC/EN 60947-4-1, Annex F) Rated impulse withstand voltage Overvoltage category/pollution degree DILM7-… DILM38-… DILAXHI(C)…(-S) DILM32XHI(C)…(-S) DILM150XHI… DILM1000-XHI… DILM820-XHI… - Yes Yes Yes Yes DILM7 DILM38 DILM7 DILM38 DILM7 DILM38 DILM40 DILM170 DILM40 - DILM225A DILM250 - DILM1000 Uimp V AC 6000 III/3 6000 III/3 6000 III/3 6000 III/3 6000 III/3 Rated insulation voltage Ui V AC 690 690 690 690 690 Rated operating voltage Ue V AC 500 500 500 500 500 Safe isolation according to EN 61140 Between coil and auxiliary contacts Between the auxiliary contacts Rated operational current V AC 400 400 400 440 440 V AC 400 400 400 440 440 AC-15 DC L/R 230 V 380/415 V Ie Ie A A 4 4 4 4 4 4 4 4 4 4 500 V 1.5 Ie A 1.5 – 1.5 1.5 15 ms 2) 24 V Ie A 10 10 10 10 10 60 V Ie A 6 6 6 6 6 110 V Ie A 3 3 3 3 3 220 V Ie A 1 1 1 1 1 3 3 24 V 60 V A A 2.5 1 2.5 1 2.5 1 – – – – 3 3 110 V 220 V A A 0.5 0.25 0.5 0.25 0.5 0.25 – – – – I th Fault probability A 10 16 16 < 10 -8 , < 1 one failure in 100 million operations 16 10 c (contacts) x 10 6 1.3 1.3 1.3 1.3 A gG/gL 10 10 10 1) Not with DIL…-XHIV and DIL…-XHICV. 16 16 DC-13 (6xP) Contacts in series: Conventional thermal current Control circuit reliability (at Ue = 24 V DC, U min = 17 V, Imin = 5.4 mA) Component lifespan at Ue = 230 V, AC-15, 3 A 1.3 Short-circuit rating without welding Max. fuse Notes 128 2) Switch-on and switch-off conditions based on DC-13, time constant as specified. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.1 Contactors Paralleling link P1SIL...M, DILM...-XP1 1 P1DILEM DILM12-XP1 DILM32-XP1 DILM65-XP1 DILM150-XP1 DILM185-XP1 16 1 x (16 - 35) 16 1 x (16 - 120) – – – – 1 x (16 - 50) 1 x (16 - 120) – – 1 x (35 - 300) 2 x (35 - 120) 2 x (11 x 21 x 1) – mm 1 - 16 1 x (0.5 - 25) 2 x (0.5 - 16) 1 x (0.5 - 25) 2 x (0.5 - 16) 6 x 9 x 0.8 Tightening torque Nm 4 4 14 14 Terminal capacity of control circuit cable Solid mm² – – – – mm² – – – – Parallel connector Terminal capacity Solid Flexible with ferrule mm² mm² Stranded mm² Flat conductor Number of layers x width x thickness Flexible with ferrule 1 x (6 x 16 x 0.8) 2 x (20 x 32 x 0.5) 2 x (11 x 21 x 1) 6 1 x (0.75 - 4) 2 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) Tools Pozidriv screwdriver Size 2 2 – – – SW mm – – 5 6 5 3 pole I th A 50 100 180 400 700 4 pole I th A 60 – – – – Internal hexagon Conventional thermal current AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 129 1.1 Contactors Minicontactor relay, contactor combination Dimensions 1 Mini contactor relays DILER-...(-C) DILER-...-G(-C) DILER-...(-C) + ...DILE(-C) DILER-...-G(-C) + ...DILE(-C) 5.5 50 58 58 M4 35 83 (86) 45 52 (54) 45 DILEEM-..., DILEM-...(-C), DILEM-12-... DILEEM-...-G, DILEM-...-G(-C), DILEM-12-...-G c Part no. c c1 DILE(E)M-...(-G) 52 DILE(E)M-...-G(-C) 54 50 58 M4 83 86 35 c1 45 Suppressor circuit DILER-... + HDILE DILER-...-...G + HDILE RCDILE... VGDILE 62.5 45 58 43 45 52 45 65,3 2DILE-... + MVDILE + ...DILE 2DILE-...-G + MVDILE + ...DILE 58 58 2DILE-... + MVDILE 2DILE-...-G + MVDILE 90 63 94 90 Star-delta contactors SDAINLEM 108 108 61 61 Rsrotcatnocgnisreve DIULEM 94 90 180 Parallel connector DILER-... + TDDILE24 P1DILEM 83.5 75 ~125 40 65.5 45 130 4,7 67 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 83 Contactors Basic devices up to 170 A, contactor relay 1.1 1 Contactor with auxiliary contact module DILM7...DILM15 DILA... 36 68 45 18 60 2 x M4 35 8.7 8.7 8.7 8.7 (5.1) 3.2 6.5 45 10.2 75 c Part no. c DILM32-XHI DILA-XHI DILA-XHI...T 117 117 125 DILMC7...DILMC15 DILAC... DILA-XHIC... 1.8 6.5 8.7 8.7 8.7 (5.1) 75 45 10.2 35 3.2 1.8 8.7 60 68 52.3 26.4 2 x M4 125 DILM17...DILM38 DILMC17...DILMC32 DILMF8...DILMF32 75 71 38 85 35 4.5 4.5 11 4.8 11.611.6 Clearance at side to grounded parts: 6 mm 6.5 97.4 17.7 6.4 60.4 2 x M4 10.6 138 45 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 131 1.1 Contactors Basic devices up to 170 A, suppressor circuit 1 Contactors DILM40...DILM72 DILMC40...DILMC65 DILMF40...DILMF65 105 115 104 57 86.4 2 x M4 34.4 4.7 55 6.9 45 Clearance at side to grounded parts: 6 mm 114 77 132.1 147 DILM80...DILM170 DILMC80...DILMC150 DILMF80...DILMF150 156 156 170 76.5 57 4 x M6 90 82.5 111 85.5 70 142 160 175 Clearance at side to grounded parts: 10 mm Suppressor circuits b a 132 b1 DILM...XSP... c AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Part no. a b DILM12-XSP... DILM32-XSP... DILM95-XSP... 25 25 25 28 28 28 b1 c 32 32 32 9 9 9 Contactors Basic devices up to 200 A 1.1 Contactor with auxiliary contact module 1 DILMP20 60 68 45 18 2 x M4 35 3.2 36 6.5 45 75 117 DILMP32 DILMP45 75 85 71 60.4 38 2 x M4 35 4.5 58 Distance at side to grounded parts: 6 mm 6.5 97.4 138 Contactors DILMP63 DILMP80 105 115 104 86.4 57 2 x M4 74 4.7 85 6.9 45 Distance at side to grounded parts: 6 mm 114 132.1 147 DILMP125 DILMP160 DILMP200 156 156 170 57 4 x M6 122 82.5 133 85.5 70 142 160 Clearance at side to earthed parts: 10 mm 175 Motor suppressor module 68 38.3 DILM12-XMSM 75 101.2 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 133 1.1 Contactors Complete units for currents greater than 170 A 1 Complete units DILM185A...DILM500 DILM250-S...DILM570-S DILM1000-XHI...-SI DILM1000-XHI11-SA a2 a 11 b1 b b3 b2 M6 e a1 f d1 c d2 8 Part no. a a1 a2 b b1 b2 b3 d1 d2 e c f DILM185A DILM225A DILM250 DILM300A DILM400 140 140 140 140 160 120 120 120 120 130 160 160 160 160 180 180 180 180 180 200 160 160 160 160 180 165 165 164 164 184 190 190 189 189 209 20 20 25 25 25 41 41 48 48 48 5 5 5 5 6 158 158 208 208 216 83 83 140 140 140 DILM500 160 130 180 200 180 189 219 38 57 6 216 140 DILM570 160 130 180 200 180 189 219 38 57 6 216 140 DILM580...DILM1000 f 215 b3 b2 232 M6 165 80 e d1 250 140 232 270 DILM820-XHI...-SI DILM820-XHI11-SA 134 Part no. DILM580 DILM650 DILM750 DILM820 DILM1000 b2 256 256 256 256 256 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical b3 296 296 296 296 296 d1 45 45 45 45 45 e 6 6 6 6 10 f 13.5 13.5 13.5 13.5 13.5 Contactors Contactors greater than 1000 A 1.1 AC -1 contactors greater than 1000 A 1 DILH1400 215 232 342 256 308 35 210 M6 165 14 60 100 130 35 10 100 232 260 DILM1600 DILH2000 DILH2200 270 300 392 272 352 96 210 M6 14 430 40 40 80 80 150 172.5 150 10 252 125 172.5 515 DILH2600 270 300 422 206 160 210 (342) 136 M6 430 14 40 40 80 80 150 172.5 150 10 252 125 172.5 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 135 1.1 Contactors Capacitor contactors, lamp contactors, contactor monitoring devices, SWD contactor modules 1 Contactor for capacitors DILK… b b1 Part no. DILK12 DILK20 DILK25 DILK33 DILK50 d a1 a c a 45 45 45 55 55 b 135 135 135 190 190 c 138 138 138 147 147 a1 35 35 35 45 45 b1 75 75 75 105 105 d 2 x M4 2 x M4 2 x M4 2 x M4 2 x M4 Illumination contactors DILL… 75 85 38 60.4 2 x M4 35 4.5 4.5 4.8 6.5 17.7 Clearance at side to grounded parts: 6 mm 97.4 11.6 11.6 10.6 (6.4) 45 138 Contactor monitoring devices CMD(...) 103 98 78 82.5 22.5 SWD contactor modules 38 DIL-SWD-32-... 45 53.1 72.3 136 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Contactors Contactor combinations 1.1 Star-delta contactors 1 b SDAINLM12...SDAINLM115 a Part no. SDAINLM12...22 SDAINLM30...55 SDAINLM70...115 c a 158 158 188 b 68 85 115 c 117 138 147 299 144 144 314 SDAINLM140...SDAINLM260 183 M6 308 Reversing contactors b DIULM7...DIULM65 a c Part no. DIULM7/21...12/21 DIULM17/21...32/21 DIULM40/11...65/11 a 90 90 110 b 68 85 115 c 117 138 147 176 314 299 DIULM80…DIULM150 M6 183 196 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 137 1.1 Contactors Accessories 1 Three-phase commoning links DILM12-XDSB... 13.1 18.1 Part no. DILM12-XDSB0/3 a 12.5 a 112 157 DILM12-XDSB0/4 DILM12-XDSB0/5 202 Amplifier module DILM…XTE ETS4- VS3 78 82.5 70 45 103 98 22.5 25 38 Electronic timer modules Wiring set for motor feeder plug DILM12- XMCP/T 30 45 45 20 45 37 20 DILM12- XMCE 80 6 25 25 50 30 27 45 20 30 37 DILM12-XMCP/E 6 25 80 45 50 27 138 12 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 12 1.1 Contactors Contactors with terminal shrouds 1 DILM250...DILM1000 + DILM...-XHB DILM250 + Z5-.../FF250 a 523 328 b 110 150 34 for part no. a b DILM250, DILM300A DILM400 DILM500 DILM580...1000 150 150 174 236 384 404 426 506 ~144 DILM185A...DILM225A + DILM225A-XHB Contactor with star-point bridge and terminal shroud for part no. a b DILM185...250 DILM300...400 DILM500 150 150 176 127 137 146 b 325 DILM...XS1 a 124 140 Mechanical interlock DILM500- XMV DILM820- XMV a 515 a 15 430 20 270 300 for part no. DILM185...500 9 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 139 1 Overload relay Motor protection is a central task of electrical equipment for machinery. From cost-effective bimetal solutions to demanding full motor protection with cross-linkage we offer the right solution for each application. ATEX Bimetal relay - overload relay up to 630 A • Direct mounting on contactor saves mounting time. • ATEX approval for the protection of EEx e motors up to 250 A. • Comprehensive motor protection through phase failure sensitivity. • Integrated test pushbutton facilitates high safety Page 6. ZEB electronic overload relay - overload relay up to 1500 A • ATEX approval for protection of EEx e motors up to 1500 A. • Adjustable tripping classes. • Phase failure and unbalance protection. • Optional earth fault detection. • Additional current setting range (5:1) Page 14. EMT6 thermistor overload relay for machine protection • Overload protection through direct evaluation of winding temperature. • Quick detection of operating state through LED display. • Suitable for overload monitoring of motors in EEx e range. • Wide range power supply reduces amount of types Page 19. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Overload relays Contents Technical overview Bimetal relay ZE, ZB, Z5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overload relay ZW7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electronic overload relays ZEB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EMT6 thermistor overload relay for machine protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 4 4 Ordering Bimetal relays for mini-contactor relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bimetal relays up to 150 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bimetal relay greater than 150 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overload relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bimetal relay accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZEB electronic overload relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 8 12 12 21 14 1 Ordering EMT6 thermistor overload relay for machine protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Engineering EMT6 thermistor overload relay for machine protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selection criteria ZE, ZB, Z5, ZW7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Characteristic curve ZB, Z5, ZW7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL/CSA short-circuit strength ZE, ZB, Z5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 23 23 24 Technical data Bimetal relay for mini-contactor relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bimetal relays up to 150A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overload relays greater than 150 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overload relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZEB electronic overload relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EMT6 thermistor overload relay for machine protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 25 26 26 28 29 Dimensions Bimetal relays for mini-contactor relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bimetal relays up to 150A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bimetal relays greater than 150 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overload relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZEB electronic overload relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EMT6 thermistor overload relay for machine protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 30 32 32 33 35 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1 1.2 1 Overload relays Overload relays, CT-operated overload relays Technical overview Overload relays, CT-operated overload relays Electronic overload relays, thermistor overload relay for machine protection Setting ranges (A) (note max. current of the contactor) DILEM DILM7 DILM12 DILM9 DILM15 DILM17 DILM32 DILM25 DILM38 Overload relays ZE 0.1-12 ZB12 0.1-16 ZB32 0.1-38 ZB65 6-75 ZB150 35-175 Z5-.../FF225A 70-250 Z5-.../FF250 50-300 Current transformer-operated overload relay ZW7-... 42-630 2 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical DILM40 DILM65 DILM50 DILM72 DILM80 DILM150 DILM95 DILM170 DILM115 Overload relays Overload relays, CT-operated overload relays 1.2 1 DILM185A DILM225A DILM250 DILM300 DILM400 DILM580 DILM500 DILM650 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 3 1.2 Overload relays Electronic overload relays, thermistor overload relay for machine protection 1 Electronic overload relays, thermistor overload relay for machine protection Setting ranges (A) (note max. current of the contactor) DILEM DILM7 DILM12 DILM9 DILM15 DILM17 DILM32 DILM25 DILM38 Electronic overload relays ZEB12 0.33-20 ZEB32 0.33-45 ZEB65 9-100 ZEB150 20-100 ZEB32-5-(GF)/KK combined with ZEB-XCT300 60-300 ZEB-XCT600 120-600 ZEB-XCT1000 200-1000 ZEB-XCT1500 300-1500 Thermistor overload relay for machine protection EMT6((DB)K) 4 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical DILM40 DILM65 DILM50 DILM72 DILM80 DILM150 DILM95 DILM170 DILM115 Overload relays Electronic overload relays, thermistor overload relay for machine protection 1.2 1 DILM185A DILM225A DILM250 DILM300 DILM400 DILM580 DILM500 DILM650 DILM750 DILM820 DILM1000 DILM1600 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 5 1.2 1 Overload relays Bimetal relays for mini-contactor relays Ordering ZE overload relays for mini contactor relays • • • • • Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 Test/off pushbutton Reset pushbutton manual/auto Trip-free release Direct mounting Setting range of overload releases Circuit symbol Auxiliary contact For use with N/O = normally open contact NC = normally closed contact Ir Type “1” coordination gG/gL Type “2” coordination gG/gL A A A 20 0.5 20 1 0.1 – 0.16 1 N/O 1 NC 1 N/O 1 NC 0.24 – 0.4 1 N/O 1 NC 20 2 0.4 – 0.6 1 N/O 1 NC 20 2 0.6 – 1 1 N/O 1 NC 20 4 1 – 1.6 1 N/O 1 NC 20 6 1.6 – 2.4 1 N/O 1 NC 20 6 2.4 – 4 1 N/O 1 NC 20 10 4–6 1 N/O 1 NC 20 10 6–9 1 N/O 1 NC 20 10 9 – 12 1 N/O 1 NC 20 10 0.16 – 0.24 97 95 2 4 6 98 96 DILEM DIULEM/21/MV SDAINLEM Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Suitable for Max. Voltage Rating Degree of Protection See also 6 Short-circuit protection UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking E29184 NKCR 12528 3211-03 UL Listed, CSA certified Branch circuits 600 V AC IEC: IP20, UL/CSA Type: Page 24 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Overload relays Bimetal relays for mini-contactor relays 1.2 1 Part no. Article no. ZE-0.16 014263 ZE-0.24 014285 ZE-0.4 014300 ZE-0.6 014333 ZE-1.0 014376 ZE-1.6 014432 ZE-2.4 014479 ZE-4 014518 ZE-6 014565 ZE-9 014708 ZE-12 014752 Price See price list Std. pack Notes 1 Off Overload release: tripping class 10 A Short-circuit protection: With direct mounting, observe the maximum permissible fuse of the contactor. With side-by-side mounting, there must be a minimum clearance of 5 mm between overload relays. Suitable for protection of EEx e motors 1 II (2) GD PTB 01 ATEX 3331 Observe manual AWB2300-1425D/GB. 1 Contactor Chapter 1.1 Accessories Page 21 Manual Page 21 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 7 1.2 Overload relays Overload relays up to 150A ZB12, ZB32 1 Setting range of overload releases ZB12 overload relay Circuit symbol For use with N/O = normally open contact NC = normally closed contact Contactors Short-circuit protection Ir Type “1” coordination gG/gL Type “2” coordination gG/gL A A A – 25 0.5 – 25 1 – 25 2 – 25 4 0.1 – 0.16 1 NC 1 N/O 1 NC 0.24 – 0.4 1 N/O 1 NC 0.4 – 0.6 1 N/O 1 NC 0.6 – 1 1 N/O 1 NC – 25 4 1 – 1.6 1 N/O 1 NC – 25 6 1.6 – 2.4 1 N/O 1 NC – 25 10 2.4 – 4 1 N/O 1 NC D S 7- 34…S X 004… 25 16 4–6 1 N/O 1 NC D S 7- 34…S X 005… 25 20 6 – 10 1 N/O 1 NC 50 25 9 – 12 1 N/O 1 NC DS7-34…SX007… DS7-34…SX009… DS7-34…SX012… 50 25 12 – 16 1 N/O 1 NC – 50 25 1 N/O 1 NC – 25 0.5 1 N/O 1 NC – 25 1 0.24 – 0.4 1 N/O 1 NC – 25 2 0.4 – 0.6 1 N/O 1 NC – 25 4 0.6 – 1 1 N/O 1 NC – 25 4 1 – 1.6 1 N/O 1 NC – 25 6 1.6 – 2.4 1 N/O 1 NC – 25 10 2.4 – 4 1 N/O 1 NC – 25 16 4–6 1 N/O 1 NC – 25 20 6 – 10 1 N/O 1 NC – 50 25 10 – 16 1 N/O 1 NC DS7-34...SX016... 63 35 16 – 24 1 N/O 1 NC DS7-34...SX024... 100 35 24 – 32 1 N/O 1 NC DS7-34...SX032... 125 63 32 – 38 1 N/O 1 NC – 125 63 2 4 6 0.1 – 0.16 98 96 A2 14/ 22 97 95 0.16 – 0.24 2 4 6 98 96 14/ 22 DILM7, DILM9, DILM12, DILM15, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22 Soft starters 1 N/O 97 95 0.16 – 0.24 ZB32 overload relay Auxiliary contact DILM17, DILM25, DILM32, DILM38, DILMF8, DILMF11, DILMF14, DILMF17, DILMF25, DILMF32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55 Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. 8 UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking E29184 NKCR 12528 3211-03 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical NA Certification Suitable for Max. Voltage Rating Degree of Protection See also UL Listed, CSA certified Branch circuits 600 V AC IEC: IP20, UL/CSA Type: Page 24 Overload relays Overload relays up to 150A 1.2 1 Part no. Article no. ZB12-0,16 278431 ZB12-0,24 278432 ZB12-0,4 278433 ZB12-0,6 278434 ZB12-1 278435 ZB12-1,6 278436 ZB12-2,4 278437 ZB12-4 278438 ZB12-6 278439 ZB12-10 278440 ZB12-12 278441 ZB12-16 290168 ZB32-0,16 278442 ZB32-0,24 278443 ZB32-0,4 278444 ZB32-0,6 278445 ZB32-1 278446 ZB32-1,6 278447 ZB32-2,4 278448 ZB32-4 278449 ZB32-6 278450 ZB32-10 278451 ZB32-16 278452 ZB32-24 278453 ZB32-32 278454 ZB32-38 112474 Price See price list Std. pack Notes 1 Off Overload release: tripping class 10 A Short-circuit protection: With direct mounting, observe the maximum permissible fuse of the contactor. Fitted directly to the contactor 1 Suitable for protection of EEx e motors. II (2) GD PTB 04 ATEX 3022 Observe manual AWB2300-1527D/GB. • Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 • Test/off pushbutton • Reset pushbutton manual/auto • Trip-free release • Direct mounting 1 Off Overload release: tripping class 10 A Short-circuit protection: With direct mounting, observe the maximum permissible fuse of the contactor. 1 Contactor Chapter 1.1 Accessories Page 21 Manual Page 21 Fitted directly to the contactor Separate mounting 1 1 Suitable for protection of EEx e motors. II (2) GD PTB 04 ATEX 3022 Observe manual AWB2300-1527D/GB. • Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 • Test/off pushbutton • Reset pushbutton manual/auto • Trip-free release • Direct mounting 2 1 Contactor Chapter 1.1 2 Base Page 21 Manual Page 21 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 9 1.2 Overload relays Overload relays up to 150A ZB65, ZB150 1 Setting range of overload releases Circuit symbol Auxiliary contact For use with N/O = normally open contact NC = normally closed contact Ir A ZB65 overload relay • Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 • Test/off pushbutton • Reset pushbutton manual/auto • Trip-free release • Direct mounting ZB150 overload relay • Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 • Test/off pushbutton • Reset pushbutton manual/auto • Trip-free release • Direct mounting ZB150 overload relay • Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 • Test/off pushbutton • Reset pushbutton manual/auto • Trip-free release • Separate mounting 6 – 10 DILM40, DILM50, DILM65, DILM72, DILMF40, DILMF50, DILMF65, DIULM40, DIULM50, DIULM65, SDAINLM70, SDAINLM90, SDAINLM115 Type “1” coordination gG/gL A Type “2” coordination gG/gL A 50 25 63 35 63 50 125 63 160 80 1 N/O 1 NC 1 N/O 1 NC 16 – 24 1 N/O 1 NC 24 – 40 1 N/O 1 NC 40 – 57 1 N/O 1 NC 50 – 65 1 N/O 1 NC 160 100 65 – 75 1 N/O 1 NC 250 160 1 N/O 1 NC 160 125 1 N/O 1 NC 250 160 70 – 100 1 N/O 1 NC 315 200 95 – 125 1 N/O 1 NC 315 250 120 – 150 1 N/O 1 NC 315 250 145 – 175 1 N/O 1 NC DILM80, DILM95, DILM115, DILM150, DILM170 DILMF80, DILMF95, DILMF115, DILMF150, DIULM80, DIULM95, DIULM115, DIULM150, SDAINLM140, SDAINLM165, SDAINLM200, SDAINLM260 315 250 1 N/O 1 NC 160 125 1 N/O 1 NC 250 160 70 – 100 1 N/O 1 NC 315 200 95 – 125 1 N/O 1 NC 315 250 120 – 150 1 N/O 1 NC 315 250 145 – 175 1 N/O 1 NC DILM80, DILM95, DILM115, DILM150, DILM170 DILMF80, DILMF95, DILMF115, DILMF150, DIULM80, DIULM95, DIULM115, DIULM150, SDAINLM140, SDAINLM165, SDAINLM200, SDAINLM260 400 315 10 – 16 97 95 2 4 6 35 – 50 98 96 97 95 50 – 70 2 4 6 35 – 50 50 – 70 98 96 97 95 2 4 6 98 96 Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Suitable for Max. Voltage Rating Degree of Protection See also 10 Short-circuit protection UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking E29184 NKCR 12528 3211-03 UL Listed, CSA certified Branch circuits 600 V AC IEC: IP00, UL/CSA Type: Page 24 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Overload relays Overload relays up to 150A 1.2 1 Part no. Article no. ZB65-10 278455 ZB65-16 278456 ZB65-24 278457 ZB65-40 278458 ZB65-57 278459 ZB65-65 278460 ZB65-75 108792 ZB150-50 278462 ZB150-70 278463 ZB150-100 278464 ZB150-125 278465 ZB150-150 278466 ZB150-175 107316 ZB150-50/KK 278468 ZB150-70/KK 278469 ZB150-100/KK 278470 ZB150-125/KK 278471 ZB150-150/KK 278472 ZB150-175/KK 107317 Price See price list Std. pack Notes 1 Off Overload release: tripping class 10 A Short-circuit protection: With direct mounting, observe the maximum permissible fuse of the contactor. Fitted directly to the contactor Separate mounting Suitable for protection of EExe motors. 1 II (2) GD PTB 04 ATEX 3022 1 Observe manual AWB2300-1545D/GB. 1 Off Overload release: tripping class 10 A Short-circuit protection: With direct mounting, observe the maximum permissible fuse of the contactor. 2 Suitable for protection of EEx e motors. II (2) GD PTB 04 ATEX 3022 Observe manual AWB2300-1545D/GB. 1 Off Overload release: tripping class 10 A Short-circuit protection: With direct mounting, observe the maximum permissible fuse of the contactor. 1 Contactor Chapter 1.1 2 Base Page 21 Manual Page 21 Suitable for protection of EEx e motors. II (2) GD PTB 04 ATEX 3022 Observe manual AWB2300-1545D/GB. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 11 1.2 Overload relays Overload relays greater than 150 A, CT-operated overload relays Z5, ZW7 1 Setting range of overload releases Circuit symbol Auxiliary contacts For use with N/O = normally open contact NC = normally closed contact Short-circuit protection Type “1” coordination gG/gL Type “2” coordination gG/gL A A 250 250 315 315 160 160 200 200 Ir A Z5 overload relays greater than 150A • Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 • Test/off pushbutton • Reset pushbutton manual/auto • Trip-free release Direct mounting Separate mounting Z5 overload relays greater than 150A • Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 • Test/off pushbutton • Reset pushbutton manual/auto • Trip-free release Direct mounting Separate mounting ZW7 current transformer-operated overload relays • Test/off button • Reset pushbutton manual/auto • Trip-free release • Protection with heavy starting duty Separate mounting 12 50 – 70 1 N/O 1 NC 1 N/O 1 NC 95 – 125 1 N/O 1 NC 315 315 250 250 120 – 160 1 N/O 1 NC 400 400 250 250 160 – 220 1 N/O 1 NC 400 500 315 400 200 – 250 1 N/O 1 NC 400 500 315 400 70 – 100 1 N/O 1 NC 250 250 160 160 70 – 100 1 N/O 1 NC 95 – 125 1 N/O 1 NC 315 315 315 315 200 200 250 250 120 – 160 1 N/O 1 NC 400 400 250 250 160 – 220 1 N/O 1 NC 200 – 250 1 N/O 1 NC 200 – 300 1 N/O 1 NC DILM300A 400 500 400 500 500 500 315 400 315 400 400 400 1 N/O 1 NC – – – 1 N/O 1 NC – – – 1 N/O 1 NC – – – 110 – 160 1 N/O 1 NC – – – 160 – 240 1 N/O 1 NC – – – 190 – 290 1 N/O 1 NC – – – 270 – 400 1 N/O 1 NC – – – 360 – 540 1 N/O 1 NC – – – 420 – 630 1 N/O 1 NC – – – 1 3 5 97 95 2 4 6 98 96 70 – 100 42 – 63 DILM185A DILM225A DILM250A 97 95 60 – 90 85 – 125 98 96 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Overload relays Overload relays greater than 150 A, CT-operated overload relays 1.2 1 Part no. Article no. Z5-70/FF225A 139572 Z5-100/FF225A 139573 Z5-125/FF225A 139574 Z5-160/FF225A 139575 Price See price list Std. pack Notes Information relevant for export to North America 1 Off Overload release: tripping class 10 A Short-circuit protection: With direct mounting, observe the maximum permissible fuse of the contactor. Product Standards Z5-…/FF225A for protecting EEx electric motors in preparation. NA Certification Suitable for Max. Voltage Rating Degree of Protection See also Fitted directly to the contactor Z5-220/FF225A 139576 Z5-250/FF225A 139577 1 Z5-70/FF250 210070 Product Standards Z5-100/FF250 210071 Z5-125/FF250 210072 Z5-160/FF250 210073 UL File No. UL CCN CSA File No. CSA Class No. NA Certification Suitable for Max. Voltage Rating Degree of Protection See also 1 Contactor Accessories Z5-220/FF250 210074 Chapter 1.1 Page 22 Z5-250/FF250 210075 Z5-300/FF250 139578 Product Standards NA Certification Suitable for Max. Voltage Rating Degree of Protection ZW7-63 000245 ZW7-90 002618 UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking Request filed for UL and CSA Branch circuits 600 V AC IEC: IP00, UL/CSA Type: Page 24 1 Off ZW7-125 004991 ZW7-160 007364 ZW7-240 009737 The main current characteristic values are defined by the main current wiring being used. Adjustment for smaller rated motor currents Page 23 Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Suitable for Max. Voltage Rating Degree of Protection UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking E29184 NKCR 12528 3211-03 UL Listed, CSA certified Branch circuits 600 V AC IEC: IP00, UL/CSA Type: Page 24 UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking Request filed for UL and CSA Branch circuits 600 V AC IEC: IP00, UL/CSA Type: UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking E29184 NKCR 12528 3211-03 UL Listed, CSA certified Branch circuits 600 V AC IEC: IP00, UL/CSA Type: - ZW7-290 052448 ZW7-400 045329 ZW7-540 047702 ZW7-630 050075 1 O ff – AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 13 1.2 Electronic overload relays to 1500 A Basic devices ZEB12, ZEB32 1 Ground fault detection ZEB12 electronic overload relay • Phase-failure sensitivity • Test/off pushbutton • Reset button • Manual/Auto reset selectable • Protection with heavy starting duty (Class 5-30) Direct mounting ZEB32 electronic overload relay • Phase-failure sensitivity • Test/off pushbutton • Reset button • Manual/Auto reset selectable • Protection with heavy starting duty (Class 5-30) Direct mounting ZEB32 electronic overload relay • Phase-failure sensitivity • Test/off pushbutton • Reset button • Manual/Auto reset selectable • Protection with heavy starting duty (Class 5-30) Separate mounting Setting range of overload releases Ir A Without 0.33 – 1.65 Without 1–5 Circuit symbol For use with N/O = normally open contact NC = normally closed contact 97 95 2 4 6 1 N/O 1 NC 1 N/O 1 NC 98 96 Without 4 – 20 1 N/O 1 NC With 0.33 – 1.65 1 N/O 1 NC With 1–5 1 N/O 1 NC With 4 – 20 1 N/O 1 NC Without 0.33 – 1.65 1 N/O 1 NC Without 1–5 1 N/O 1 NC Without 4 – 20 1 N/O 1 NC Without 9 – 45 1 N/O 1 NC With 0.33 – 1.65 1 N/O 1 NC With 1–5 1 N/O 1 NC With 4 – 20 1 N/O 1 NC With 9 – 45 1 N/O 1 NC Without 0.33 – 1.65 1 N/O 1 NC Without 1–5 1 N/O 1 NC Without 4 – 20 1 N/O 1 NC Without 9 – 45 1 N/O 1 NC With 0.33 – 1.65 1 N/O 1 NC With 1–5 1 N/O 1 NC With 4 – 20 1 N/O 1 NC With 9 – 45 1 N/O 1 NC 97 95 2 4 6 98 96 1 3 5 97 95 2 4 6 98 96 Information relevant for export to North America Product Standards NA Certification Suitable for Max. Voltage Rating Degree of Protection 14 Auxiliary contact UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking Request filed for UL and CSA Branch circuits 600 V AC IEC: IP20, UL/CSA Type: - AUTOMATION AND CONTROL www.eaton.com/seasia-electrical DILM7 DILM9 DILM12 DILM15 DIULM7 DIULM9 DIULM12 SDAINLM12 SDAINLM16 SDAINLM22 DILM17 DILM25 DILM32 DILM38 DIULM17 DIULM25 DIULM32 SDAINLM30 SDAINLM45 SDAINLM55 DILM17 DILM25 DILM32 DILM38 DIULM17 DIULM25 DIULM32 SDAINLM30 SDAINLM45 SDAINLM55 Electronic overload relays to 1500 A Basic devices 1.2 1 Part no. Article no. ZEB12-1,65 136480 ZEB12-5 136481 Price See price list Std. pack Notes 1 Off Suitable for protection of EEx e motors. Fitted directly to the contactor II (2) GD PTB ATEX starting 08/2010 ZEB12-20 136482 ZEB12-1,65-GF 136483 1 Observe manual AWB2320-1633D/GB. Switchgear and cable dimensioning according to CLASS Page 18 ZEB12-5-GF 136484 ZEB12-20-GF 136485 1 Contactor Accessories ZEB32-1.65 136486 1 Off Suitable for protection of EEx e motors. ZEB32-5 136487 II (2) GD PTB ATEX starting 08/2010 ZEB32-20 136488 ZEB32-45 136489 ZEB32-1,65-GF 136490 Observe manual AWB2320-1633D/GB. Chapter 1.1 Page 18 Fitted directly to the contactor 1 Switchgear and cable dimensioning according to CLASS Page 18 ZEB32-5-GF 136491 ZEB32-20-GF 136492 ZEB32-45-GF 136493 ZEB32-1,65/KK 136494 ZEB32-5/KK 136495 ZEB32-20/KK 136496 ZEB32-45/KK 136497 ZEB32-1,65-GF/KK 136498 ZEB32-5-GF/KK 136499 ZEB32-20-GF/KK 136500 1 Off Suitable for protection of EEx e motors. 1 Contactor Accessories II (2) GD PTB ATEX starting 08/2010 Chapter 1.1 Page 18 Observe manual AWB2320-1633D/GB. Switchgear and cable dimensioning according to CLASS Page 18 ZEB32-45-GF/KK 136501 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 15 1.2 Electronic overload relays to 1500 A Basic devices ZEB65, ZEB150 1 Ground fault detection Setting range of overload releases Ir A 9 – 45 With 9 – 45 Without Auxiliary contact For use with N/O = normally open contact NC = normally closed contact 1 N/O 1 NC 1 N/O 1 NC 20 – 100 1 N/O 1 NC With 20 – 100 1 N/O 1 NC ZEB150 electronic overload relay • Phase-failure sensitivity • Test/off pushbutton • Reset button • Manual/Auto reset selectable • Protection with heavy starting duty (Class 5-30) Direct mounting Without 20 – 100 1 N/O 1 NC With 20 – 100 1 N/O 1 NC ZEB150 electronic overload relay • Phase-failure sensitivity • Test/off pushbutton • Reset button • Manual/Auto reset selectable • Protection with heavy starting duty (Class 5-30) Separate mounting Without 20 – 100 1 N/O 1 NC With 20 – 100 1 N/O 1 NC ZEB65 electronic overload relay • Phase-failure sensitivity • Test/off pushbutton • Reset button • Manual/Auto reset selectable • Protection with heavy starting duty (Class 5-30) Direct mounting Without Circuit symbol 97 95 2 4 6 98 96 97 95 2 4 6 98 96 1 3 5 97 95 2 4 6 98 96 Information relevant for export to North America Product Standards NA Certification Suitable for Max. Voltage Rating Degree of Protection 16 UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking Request filed for UL and CSA Branch circuits 600 V AC IEC: IP20, UL/CSA Type: - AUTOMATION AND CONTROL www.eaton.com/seasia-electrical DILM40 DILM50 DILM65 DILM72 DIULM40 DIULM50 DIULM65 SDAINLM70 SDAINLM90 SDAINLM115 DILM80 DILM95 DILM115 DILM150 DIULM80 DIULM95 DIULM115 DIULM150 SDAINLM140 SDAINLM165 SDAINLM200 SDAINLM260 DILM80 DILM95 DILM115 DILM150 DIULM80 DIULM95 DIULM115 DIULM150 SDAINLM140 SDAINLM165 SDAINLM200 SDAINLM260 Electronic overload relays to 1500 A Basic devices 1.2 1 Part no. Article no. ZEB65-45 136502 ZEB65-45-GF 136503 Price See price list Std. pack Notes 1 Off Suitable for protection of EEx e motors. Fitted directly to the contactor II (2) GD PTB ATEX starting 08/2010 ZEB65-100 136504 ZEB65-100-GF 136505 1 Observe manual AWB2320-1633D/GB. Switchgear and cable dimensioning according to CLASS Page 18 1 Contactor Accessories ZEB150-100 136506 1 Off Suitable for protection of EEx e motors. Chapter 1.1 Page 18 Fitted directly to the contactor II (2) GD PTB ATEX starting 08/2010 ZEB150-100-GF 136507 1 Observe manual AWB2320-1633D/GB. Switchgear and cable dimensioning according to CLASS Page 18 ZEB150-100/KK 136508 ZEB150-100-GF/KK 136509 1 Off Suitable for protection of EEx e motors. II (2) GD PTB ATEX starting 08/2010 Observe manual AWB2320-1633D/GB. 1 Contactor Accessories Chapter 1.1 Page 18 Switchgear and cable dimensioning according to CLASS Page 18 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 17 1.2 Electronic overload relays to 1500 A Accessories 1 ZEB-XCT… Setting range of overload releases Language Can be used with Part no. Article no. Price See price list Std. pack Ir A Current sensors 60 – 300 – ZEB32-5-GF/KK ZEB32-5/KK ZEB-XCT3001) 136511 1off 120 – 600 – ZEB32-5-GF/KK ZEB32-5/KK ZEB-XCT6001) 136512 1off 200 – 1000 – ZEB32-5-GF/KK ZEB32-5/KK ZEB-XCT10001) 136517 1off 300 – 1500 – ZEB-XCT15001) 136513 1off – – – ZEB-XSC2) 136514 1 off – – – ZEB-XRB2) 136515 1 off – Deutsch English ZEB12 ZEB32 ZEB65 ZEB150 AWB2320-1633DE/EN 136516 1 off Sealable shroud Cover to prevent adjustment of motor current (tamper-proof) Reset adapter Cover to prevent adjustment of motor current (tamper-proof) Documentation ZEB electronic overload relay Overload monitoring of EEx e motors 1) 2) Information relevant for export to North America Information relevant for export to North America Product Standards Product Standards NA Certification Suitable for Max. Voltage Rating Degree of Protection UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking Request filed for UL and CSA Branch circuits 600 V AC IEC: IP00, UL/CSA Type: - NA Certification Max. Voltage Rating Degree of Protection UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking Request filed for UL and CSA 600 V AC IEC: IP20, UL/CSA Type: - Switchgear and cable sizing corresponding to the respective starting inertia (CLASS) for ZEB Switchgear is designed according to "CLASS 10" requirements for both normal and overload operation conditions. In order for the switchgear (circuit-breaker and contactor) and the cables not to be overloaded with long tripping times, they must be overdimensioned accordingly. The rated operational current, Ie, for switchgear and cables can be calculated with the following current factor taking the tripping class into account: Trippling class Class 5 Class 10 Class 15 Class 20 Class 25 Class 30 Class 35 Class 40 Current factor of rated operational current Ie 1.00 1.00 1.22 1.41 1.58 1.73 1.89 2.00 18 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.2 Overload relays for machine protection Basic devices, accessories Ordering 1 EMT6 Function Rated operational current Conventional thermal AC-15 AC-14 current 240 V 400 V Rated control voltage Part no. Article no. Ie Ie I th Us A A A V 6 24 - 240 V 50/60 Hz, EMT61) 2) 066166 24 - 240 V DC 230 V 50/60 Hz EMT6(230V)1) 2) 066400 Price See price list Std. pack Notes EMT6 thermistor machine protection overload relays Without automatic reset Mains and fault LED display 3 3 Without automatic reset Mains and fault LED display Tripped in the event of a short-circuit in the sensor-cable 3 Selector switch with/without automatic reset For manual or remote resetting Test button Mains and fault LED display 3 Selector switch with/without automatic reset For manual or remote resetting Test button Mains and fault LED display Trip with short-circuit in the sensor cable 3 3 6 24 - 240 V 50/60 Hz, EMT6-KDB 2) 24 - 240 V DC 269471 All-in-one device Selector switch with/without automatic reset Trip with short-circuit in the sensor cable Zero-voltage safe For manual or remote resetting Test button Short-circuit detection and retention can be deactivated Mains and fault LED display 3 3 6 24 - 240 V 50/60 Hz, EMT6-DBK 2) 24 - 240 V DC 066168 3 3 1 off II (2) G II (2) GD only for EMT6-K 24 - 240 V 50/60 Hz, EMT6-K 2) 24 - 240 V DC 269470 6 PTB 02 ATEX 3162 Observe the manual AWB 2327-1446 Page 19 Can be snap fitted on a top-hat rail to IEC/EN 60715. Device clearance ̱ 3 mm. 24 - 240 V 50/60 Hz, EMT6-DB1) 2) 24 - 240 V DC 066167 6 230 V 50/60 Hz EMT6-DB(230V)1) 2) 066401 Accessories Screw adapters for screw fixing Documentation EMT6 thermistor overload relay Overload monitoring of machines in the EEx e area German English 1) Notes CS-TE 3) 095853 10 off AWB2327-1446D 264853 AWB2327-1446GB 267010 1 off 1 off For EMT6, EMT6(230V), EMT6-DB and EMT6-DB(230V) applies: Provide additional short-circuit protection in the sensor circuit with a current monitoring relay. 2) 3) Information relevant for export to North America Information relevant for export to North America Product Standards UL/CSA certification not required UL File No. UL CCN CSA File No. CSA Class No. NA Certification Max. Voltage Rating Degree of Protection UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking E29184 NKCR 12528 3211-03 UL Listed, CSA certified 600 V AC IEC: IP20, UL/CSA Type: - – AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 19 1.2 Selection aid Engineering Terminal marking according to EN 50005 EMT6(-K), EMT6-(K)DB, EMT6-DBK Auto EMT6-(K)DB, EMT6-DBK Manual ~ L+ ~ L+ A1/A2 A1/A2 T1/T2 21 A1 Power 3.6 K 1.6 K 0 T1/T2 Y1 Y2 A1 13 Power Tripped 21 13 T1 T2 22 1.6 k 0 Y1/Y2, RESET US Tripped LED A2 3.6 K Tripped 13–14, 21–22 US 13–14, 21–22 22 14 T1 T2 A2 14 Tripped LED PTC PTC N~ N~ EMT6-DBK Zero-voltage safe operation LED display ~ L+ A1/A2 T1/T2 Y1 Y2 A1 Power Y3 Y4 21 13 Supply voltage present 3.6 K 1.6 K 0 Device has tripped Tripped Device has tripped/short-circuit in the sensor circuit Y1/Y2, RESET US 13–14, 21–22 T1 T2 A2 22 14 Tripped LED Short-circuit PTC N ~– Sensor circuit At R K ̰ 250 ȍ per sensor: 6 sensors, at RK̰100 ȍ per sensor: 9 sensors in the winding (provided by user), max. cable length to sensor 250 m (not shielded); Total PTC thermistor resistance R K̰1500 ȍ Sensor circuit characteristic values at Us and +20 °C 12000 R T1-T2 EMT6… U T1-T2 V DC max. I T1-T2 mA max. T1, T2 short-circuited 4 kȍ T1-T2 open 3 5.1 1.9 0.8 - Resistance [ ] 1 Overload relays for machine protection 4000 3600 IECTripping range 1650 Resetting range 1600 Disconnection by link Short-circuit monitoring Zero-voltage safety Y1 - Y 3 Y1 - Y 4 20 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Reset 750 Tolerance limits Temperature [°C] Functions that can be disconnected on the EMT6-DBK: Function Tripping 60 NAT NAT –20° –5° NAT NAT NAT +5° +15° Overload relays Accessories 1.2 Ordering 1 ZB, Z5, ZW7 For use with Part no. Article no. Std. pack Notes AWB2300-1425D 258704 AWB2300-1527D/GB 284910 AWB2300-1545D/GB 102065 1 off German 1 off German/English 1 off German/English ZB32 ZB32-XEZ 278473 5 off ZB65 ZB65-XEZ 278474 2 off Can be snap fitted on a top-hat rail to IEC/EN 60715 or can be screw fitted. For ZB32-38, use BK25/3-PKZ0 additionally. ZW7... ZE Z5 ZB12 ZB32 ZB65 ZB150 M22-DZ-B 254833 10 off ZW7... ZE Z5 ZB12 ZB32 ZB65 ZB150 M22-DZ-B-GB14 254834 10 off Button plate, blue RESET Pushbuttons For enclosed Overload relay Mounting diameter: 22.3 mm Off button, IP65 ZW7... ZE Z5 ZB12 ZB32 ZB65 ZB150 M22-DZ-X 254835 10 off Without button plate, add button plate. Pushbuttons For enclosed Overload relay Mounting diameter: 22.3 mm Button plates M22-DZ-X M22-XD-R 216423 M22-XD-R-X0 218153 Documentation Overload relays Overload monitoring of EEx e motors Bases For separate mounting Pushbuttons For enclosed Overload relay Mounting diameter: 22.3 mm External reset button, IP65 ZE… ZB12… ZB32… ZB65… ZB150… M22-DZ-X M22-DZ-X Price See price list Button plate, blue Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Max. Voltage Rating Degree of Protection Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification M22-XD-R-GB0 218194 10 off Button plate, red UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking E29184 NKCR 12528 3211-03 UL Listed, CSA certified 600 V AC IEC: IP00, UL/CSA Type: UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking E29184 NKCR 12528 3211-03 UL Listed, CSA certified UL 508; CSA-C22.2 No.14; IEC/EN 60947-4-1; CE marking E29184 NKCR 12528 3211-03 UL Listed, CSA certified UL/CSA certification not required Red button plate with white circle Button plate red STOP AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 21 1.2 Overload relays Accessories Z5..., K-B..., KS-B... 1 Covers For use with Part no. Article no. Direct mounting Z5-…/FF225 to DILM185A DILM225A Z5/FF225A-XHB-Z 139579 Price See price list Std. pack Notes 1 off Fitted directly to the contactor DILM400 -XHB DILM185A/ 225A Z5/FF225A -XHB-Z Z5-.../FF225A Z5/FF250 -XHB Z5-…/FF225A Z5-…/FF250 Covers Z5/FF250-XHB 215217 1 off Separate mounting Z5/FF250 -XHB Z5-.../FF250/ FF225A Z5/FF250 -XHB Direct mounting Z5-…/FF250 to DILM250 DILM300A Covers Z5/FF250-XHB-Z 215218 1 off Fitted directly to the contactor Fitted directly to the contactor DILM400 -XHB DILM400 -XHB DILM250/ 300A DILM185A/ 225A Z5/FF250 -XHB-Z Z5/FF225A -XHB-Z Z5-.../FF250 Z5-.../FF225A Z5/FF250 -XHB Z5/FF250 -XHB Fitted directly to the contactor DILM400 -XHB DILM250/ 300A Z5/FF250 -XHB-Z Z5-.../FF250 Z5/FF250 -XHB Box terminals kit Consisting of 3 individual clamps For use with For connection of copper flat strip max. WxH mm Part no. Article no. With protective cover Z5-…/FF250 24 x 26 With control circuit terminal and protective cover Z5-…/FF250 24 x 26 22 Price See price list Std. pack Notes K-B-DIL6AM 064062 1 off When using box terminals the protective covers must be used. KS-B-DIL6AM 064063 1 off When using box terminals the protective covers must be used. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.2 Overload relays Selection criteria Engineering 1 Protection of single-phase and DC current motors: Mounting position: 1 pole ZE 2 pole ZB12, ZB32, ZB65, ZB150, Z5 Tripping characteristics These tripping characteristics are mean values of the spread at 20 °C ambient temperature in a cold state. They show the tripping times in relation to the response current. When the devices are at operational temperature the tripping time of the overload relay drops to approx. 25% of the value shown. Specific characteristics for each individual setting range can be found in the manual on Page 21 1 1.5 2 3 4 6 8 10 15 20 x Setting current Minutes 3-phase 2-phase 1 1.5 2 3 4 6 8 10 15 20 x Setting current 2h 100 60 40 20 10 6 4 2 1 40 20 10 6 4 2 1 0.6 Z5 Minutes ZW7 Maximum 3 phase Seconds 2-phase 2h 100 60 40 20 10 6 4 2 1 40 20 10 6 4 2 1 0.6 ZB150 Minimum Seconds 3-phase Seconds Seconds 2h 100 60 40 20 10 6 4 2 1 40 20 10 6 4 2 1 0.6 Minutes ZB12, ZB32, ZB65, ZE Minutes 2h 100 60 40 20 10 6 4 2 1 40 20 10 6 4 2 1 0.6 1 1.5 2 3 4 6 8 10 15 20 x Setting current 2 phase 1 1.5 2 3 4 6 8 10 15 20 x Setting current Adaption of ZW7 to smaller rated motor currents Number of loops ZW7 -63 -90 1 2 3 4 5 Rated motor current IN [A] 42-63 60-90 21-31,5 30-45 14-21 20-30 10.5-15,8 15-22,5 8.4-12,6 12-18 -125 -160 -240 -290 -400 -540 -630 85-125 42.5-62,5 28.3-41,7 21.3-31,3 17-25 110-160 55-80 36.7-53,3 27.5-40 22-32 160-240 80-120 53.3-80 40-60 32-48 190-290 95-145 63.3-96,7 47.5-72,5 38-58 270-400 135-200 90-133,3 67.5-100 54-80 360-540 180-270 120-180 90-135 72-108 420-630 210-315 140-210 105-157,5 84-126 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 23 1.2 Overload relays UL/CSA-short-circuit strength 1 ZE, ZB, Z5 Overload relay short-circuit strength UL508, CSA-C22,2 No. 14/SCCR values ZE-0,16 ZE-0.24 ZE-0.4 ZE-0.6 ZE-1,0 ZE-1.6 ZE-2.4 ZE-4 ZE-6 ZE-9 ZE-12 ZB12(32)-0,16 ZB12(32)-0,24 ZB12(32)-0,4 ZB12(32)-0,6 ZB-12(32)-1,0 ZB-12(32)-1,6 ZB-12(32)-2,4 ZB-12(32)-4 ZB-12(32)-6 ZB-12(32)-10 ZB12-12 ZB12-16 ZB32-16 ZB32-24 ZB32-32 ZB65-10 ZB65-16 ZB65-24 ZB65-40 ZB65-57 ZB65-65 ZB65-75 24 Fuse acc. to NEC, CEC A kA CB A 600V AC 1 1 1 1 3 6 6 15 20 35 45 600V AC 1 CLASS J/CC 1 CLASS J/CC 1 CLASS J/CC 1 CLASS J/CC 1 CLASS J/CC 3 CLASS J/CC 3 CLASS J/CC 6 CLASS J/CC 10 CLASS J/CC 15 CLASS J/CC 15 CLASS J/CC 30 CLASS J/CC 35 CLASS J 45 CLASS J 60 CLASS J 600V AC 15 CLASS J 35 CLASS J 45 CLASS J 60 CLASS J 110 CLASS J 125 CLASS J 125 CLASS J 480V AC 15 15 15 15 15 15 15 15 15 15 - 5 5 5 5 5 5 5 5 5 5 5 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 600V AC 40 60 90 125 150 150 150 kA 5 5 5 5 5 5 5 5 5 5 - ZB150-50 ZB150-70 ZB150-100 ZB150-125 ZB150-150 ZB150-175 ZB150-50(KK) ZB150-70(KK) ZB150-100(KK) ZB150-125(KK) ZB150-150(KK) ZB150-175(KK) Z5-70/... Z5-100/... Z5-125/... Z5-160/... Z5-220/... Z5-250/... Z5-70/... Z5-100/... Z5-125/... Z5-160/... 5 5 5 5 10 10 10 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Fuse acc. to NEC, CEC A kA CB A 600V AC 225 250 400 CLASS J 500 CLASS J 600 CLASS J 600 CLASS J 110 CLASS J 125 CLASS J 200 CLASS J 250 CLASS J 300 CLASS J 300 CLASS J 600V AC 250 400 CLASS J 500 CLASS J 600 CLASS J 800 CLASS J 700 CLASS J 125 CLASS J 200 CLASS J 250 CLASS J 300 CLASS J 600 V AC 200 250 400 500 600 600 200 250 400 500 600 600 600V AC 250 400 500 600 800 600 - 5 10 10 10 10 10 100 100 100 100 100 100 10 10 10 10 10 10 100 100 100 100 kA 5 10 10 10 10 10 5 10 10 10 10 10 10 10 10 10 10 10 - 1.2 Overload relays Overload relays Technical data 1 ZE, ZB ZE General Standards Climatic proofing ZB12, ZB32 ZB65 ZB150(KK) IEC/EN 60947, VDE 0660, UL, CSA Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open 1) Enclosed 1) Temperature compensation °C -25…50 -25…55 -25…55 -25…55 °C -25…40 Continuous -25…40 -25…40 -25…40 kg g 0.07 10 0.15 10 0.25 10 1.64 10 IP20 IP20 IP00 IP00 Mounting position Page 23 Weight Mechanical shock resistance half-sinusoidal shock, 10 ms to IEC 60068-2-27 Protection type Protection against direct contact when actuated from front (EN 50274) Main contacts Rated impulse withstand voltage Finger- and back-of-hand proof U imp V AC Overvoltage category/pollution degree Rated insulation voltage AC Rated operating voltage Safe isolation according to EN 61140 6000 6000 6000 8000 III/3 III/3 III/3 III/3 Ui V AC 690 690 690 1000 Ue V AC 690 690 690 1000 V AC V AC 300 300 440 440 440 440 440 440 Between auxiliary contacts and main contacts Between the main contacts Overload relay setting range A 0.1…12 0.1…38 6…75 25…175 Temperature compensation residual error > 40 ºC Short-circuit protection rating maximum fuse %/K ̰0.25 Page 6 ̰0.25 Page 8 ̰0.25 Page 10 ̰0.25 Page 10 W W 2.5 6 2.5 6 3 7.5 16 18 Solid Flexible with ferrule mm² mm² 2 x (0.75 - 2.5) 2 x (0.5 - 1.5) Stranded mm² – 2 x (1 - 6) 5) 2 x (1 - 4) 5) 2 x (1 - 6) 3) – 2 x (1 - 16) 4) 1 × (1…25) 2 x (1…10) 2) 1 x (16…25) 2 x (4 - 16) 1 x (4 - 70) 2 x (4 - 50) 1 x (16…50) 2 x (16…50) AWG mm 18 - 14 – 14 - 8 5) – 14 - 2 – 3/0 – Current heat loss (3 conductors) Lower value of setting range Upper value of setting range Terminal capacity Solid or stranded Busbar Width Terminal screw Tightening torque M3.5 M4 M6 M10 Nm 1.2 1.85) 3.5 10 Size mm mm 2 0.8 x 5.5 – 2 1x6 – 2 1x6 – – – 5 Tools Pozidriv screwdriver Flat-blade screwdriver Hexagon socket Notes SW 1) Ambient temperature: Operating range to IEC/EN 60947, PTB: -5°C to +55°C Use identical cross-section when using two conductors 3) 6 mm flexible with ferrules to DIN 46228 4) With ZB65-XEZ max 1 x (1… 16) 5) ZB32-38: solid and flexible with ferrule, 2.5 - 25 mm², 3 Nm tightening torque. AWG10-b, 27 lb-in tightening torque for solid or stranded conductors. 2) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 25 1.2 Overload relays Overload relays, CT-operated overload relays 1 Z5, ZW7 Z5-…/FF225A(250) ZW7 IEC/EN 60947, VDE 0660, UL, CSA Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 IEC/EN 60947, VDE 0660, UL, CSA °C -25…50 -25…50 °C -25…40 Continuous -25…40 Continuous General Standards Climatic proofing Ambient temperature Open 1) Enclosed 1) Temperature compensation Mounting position Weight kg Page 23 1.55 Any 0.8 Mechanical shock resistance half-sinusoidal shock, 10 ms g 10 10 IP00 With terminal cover IP00 Finger- and back-of-hand proof to IEC 60068-2-27 Protection type Protection against direct contact when actuated from front (EN 50274) Main contacts Rated impulse withstand voltage Overvoltage category/pollution degree U imp V AC 8000 III/3 6000 III/3 Ui V AC 1000 690 Ue V AC 1000 690 V AC V AC 440 440 440 440 Rated insulation voltage AC Rated operating voltage Safe isolation according to EN 61140 Between auxiliary contacts and main contacts Between the main contacts Overload relay setting range A 50…300 42…630 Temperature compensation residual error > 40 ºC %/K ̰ 0.25 – Short-circuit protection rating maximum fuse Page 12 With overload relay in conjunction with a transformer as required for the contactor Current heat loss (3 conductors) Lower value of setting range W 16 3 Upper value of setting range W 28 10 mm² mm² 95 120 – – AWG mm 250 MCM 6 x 16 x 0.8 2) – – mm mm 20 x 3 – – 27 Nm M8 x 25 24 – – mm 13 – Terminal capacity Flexible with ferrule Stranded with ferrule Solid or stranded Flat conductor. Busbar Push-through opening Number of segments x width x thickness Width Terminal screw Tightening torque Tools Hexagonal socket Notes 26 SW 1) Ambient temperature: Operating range to IEC/EN 60947, PTB: -5°C to +50°C 2) Fixing with box terminals AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.2 Overload relays Overload relays, CT-operated overload relays ZE, ZB, Z5, ZW7 ZE Auxiliary and control circuits Rated impulse withstand voltage U imp V Overvoltage category/Pollution degree ZB12, ZB32 ZB65 ZB150(KK) Z5-.../FF225 Z5-.../FF250 ZW7 6000 6000 6000 6000 6000 6000 III/3 III/3 III/3 III/3 III/3 III/3 2 x (0.75 - 4) 1 Terminal capacity Solid mm² 2 x (0.75 - 2.5) 2 x (0.75 - 4) 2 x (0.75 - 4) 2 x (0.75 - 4) 2 x (0.75 - 4) Flexible with ferrule mm² 2 x (0.5 - 1.5) 2 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (0.75 - 2.5) Solid or stranded Terminal screw AWG 2 x (18 - 12) M3.5 2 x (18 - 12) M3.5 2 x (18 - 12) M3.5 2 x (18 - 12) M3.5 2 x (18 - 12) M3.5 2 x (18 - 12) M3.5 Tightening torque Nm 0.8 - 1.2 0.8 - 1.2 0.8 - 1.2 0.8 - 1.2 0.8 - 1.2 0.8 - 1.2 Tools Pozidriv screwdriver Flat-blade screwdriver Auxiliary circuit rated insulation voltage Rated operating voltage Size 2 2 2 2 2 2 Ui Ue mm V AC V AC 0.8 x 5.5 690 500 1x6 500 500 1x6 500 500 1x6 500 500 1x6 500 500 1x6 500 500 V AC 300 240 240 240 240 240 I th A 6 6 6 6 6 6 Safe isolation according to EN 61140 Between the auxiliary contacts Conventional thermal current Rated operational current AC-15 N/O 120 V Ie A 1.5 1.5 1.5 1.5 1.5 1.5 240 V Ie A 1.5 1.5 1.5 1.5 1.5 1.5 415 V Ie A 0.5 0.5 0.5 0.5 0.5 0.5 500 V Ie A 0.3 0.5 0.5 0.5 0.5 0.5 NC 120 V Ie A 1.5 1.5 1.5 1.5 1.5 1.5 240 V 415 V Ie Ie A A 1.5 0.7 1.5 0.9 1.5 0.9 1.5 0.9 1.5 0.9 1.5 0.9 500 V Ie A 0.5 0.8 0.8 0.8 0.8 0.8 0.9 DC-13 L/R ̰ 15 ms 1) 24 V Ie A 0.9 0.9 0.9 0.9 0.9 60 V Ie A 0.75 0.753) 0.753) 0.753) 0.753) 0.753) 110 V 220 V Ie Ie A A 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 AC operated V – – – – – AC operated A – – – – – General Use DC operated V 240 600 1.5 0.6 – – – – – – DC operated A – – – – – – AC operated D300 DC operated R300 B300 4) B600 5) R300 B300 4) B600 5) R300 B300 4) B600 5) R300 B300 4) B600 5) R300 B300 4) B600 5) R300 4 6 6 6 6 6 Pilot Duty Short-circuit rating without welding Max. fuse 2) Notes A gG/gL 1) Making and breaking conditions to DC-13, time constant as stated 2) See transparent overlay "Fuses" for time/current characteristics (please enquire) 3) Rated operational current DC-13, 60 V: N/O auxiliary contact 0.6 A 4) With opposite polarity 5) With same polarity AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 27 1.2 Electronic overload relays to 1500 A ZEB ZEB12, ZEB32 1 General Standards Climatic proofing ZEB65-45 ZEB65-100 ZEB150 IEC/EN 60947, VDE 0660, UL, CSA Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open Enclosed Temperature compensation Mounting position Mechanical shock resistance half-sinusoidal shock, 10 ms to IEC 60068-2-27 Protection type Protection against direct contact when actuated from front (EN 50274) Main contacts Rated impulse withstand voltage Overvoltage category/pollution degree Rated insulation voltage AC Rated operating voltage Safe isolation according to EN 61140 Between auxiliary contacts and main contacts Between the main contacts Overload relay setting range Terminal capacity Solid Solid or stranded Auxiliary and control circuits Rated impulse withstand voltage Overvoltage category/pollution degree Terminal capacity Solid Flexible with ferrule Solid or stranded Terminal screw Terminal screw Tightening torque Tools Pozidriv screwdriver Flat-blade screwdriver Auxiliary circuit rated insulation voltage Rated operating voltage Safe isolation according to EN 61140 Between the auxiliary contacts Conventional thermal current Rated operational current °C °C –25…65 –25…65 Continuous Any –25…65 –25…40 Continuous Any –25…65 –25…40 Continuous Any –25…65 –25…40 Continuous Any g 15 15 15 15 IP20 IP20 Finger- and back-of-hand proof IP20 IP20 U imp V AC 6000 III / 3 6000 III / 3 6000 III / 3 6000 III / 3 Ui Ue V AC V AC 690 690 690 690 690 690 690 690 V AC V AC A 600 600 0.3…45 600 600 9…45 600 600 20…100 600 600 20…100 mm² AWG 1 x 2.5 - 16 1 x 14 - 4 1 x 2.5 - 16 1 x 14 - 4 1 x 6 - 50 1 x 10 - 1 1 x 6 - 50 1 x 10 - 1 V 6000 III / 3 6000 III / 3 6000 III / 3 6000 III / 3 mm² mm² AWG 2 x (0.75 - 4) 2 x (0.75 - 2.5) 2 x (18 - 12) M3.5 2 x (0.75 - 4) 2 x (0.75 - 2.5) 2 x (18 - 12) M3.5 2 x (0.75 - 4) 2 x (0.75 - 2.5) 2 x (18 - 12) M3.5 2 x (0.75 - 4) 2 x (0.75 - 2.5) 2 x (18 - 12) M3.5 Nm lb-in 0.8 - 1.2 7 - 10.6 0.8 - 1.2 7 - 10.6 0.8 - 1.2 7 - 10.6 0.8 - 1.2 7 - 10.6 Ui Ue Size mm V AC V AC 2 1x6 500 500 2 1x6 500 500 2 1x6 500 500 2 1x6 500 500 I th V AC A 240 5 240 5 240 5 240 5 Ie Ie Ie Ie A A A A 1.5 1.5 0.5 0.5 1.5 1.5 0.5 0.5 1.5 1.5 0.5 0.5 1.5 1.5 0.5 0.5 Ie Ie Ie Ie A A A A 1.5 1.5 0.9 0.8 1.5 1.5 0.9 0.8 1.5 1.5 0.9 0.8 1.5 1.5 0.9 0.8 Ie Ie Ie Ie A A A A 0.9 0.75 0 0.2 0.9 0.75 0.4 0.2 0.9 0.75 0.4 0.2 0.9 0.75 0.4 0.2 A gG/gL 6 6 6 6 U imp AC-15 N/O 120 V 240 V 415 V 500 V NC 120 V 240 V 415 V 500 V DC-13 L/R ̰15 ms 24 V 60 V 110 V 220 V Short-circuit rating without welding Max. fuse 28 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Thermistor machine protection relays 1.2 EMT6 EMT6 General Standards Climatic proofing 1 IEC/EN 60947, VDE 0660, EN 55011 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open °C -25…60 Enclosed Storage Mounting position Weight °C °C -25…45 -45 - 60 Any 0.15 Shock resistance half-sinusoidal shock 10 ms to IEC 60068-2-27 Protection type g kg Protection against direct contact when actuated from front (EN 50274) Safe isolation according to EN 61140 Finger- and back-of-hand proof Between the contacts Between contacts and supply voltage Auxiliary and control circuits Rated impulse withstand voltage 10 IP20 U imp V AC 250 V AC 250 V AC Overvoltage category/pollution degree Auxiliary and control circuit terminal capacity 6000 III/3 Solid mm² AWG 1 x 2.5 2 x (0.5 - 1.5) 1 x 2.5 2 x (0.5 - 1.5) 20 - 14 Flexible with ferrule mm² Terminal screw Tightening torque Solid or stranded Nm M3.5 1.2 Tools Pozidriv screwdriver Size 2 mm 1x6 Ui V 400 415 V Ie A 3 415 V Ie A 3 240 V Ie A 3 415 V Ie A 1 Ie Ie A A 3 1 Flat-blade screwdriver Auxiliary circuit Rated insulation voltage Rated operational current AC-14 N/O NC AC-15 N/O NC 240 V 415 V Max. short-circuit protective device Fuse Control circuit Rated insulation voltage Rated operational voltage Voltage tolerance Power consumption gG/gL Ui V 240 Ue V x Ue 2401) 0.85 - 1.1 VA W ȍ ȍ 3.5 2 ̱3600 ̰1600 AC DC Trip at approx. Reset at approx. Notes 6 1) EMT6(-DB)230V: Ue = 230 V AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 29 1.2 Overload relays Dimensions Overloadrelays Base ZE-… ZB32-XEZ ZB65-XEZ 5.5 49 b2 b1 b 2xd 106 5 c2 58 32 45 a1 c 16.5 a a b c c2 a1 b1 b2 d >5 = ZB32 62 27.5 136 53 120 42 34 ZB12 84 88 39 45 27.5 102 39 OFF Reset/ON 45 ZB32-38 120 136 62 42 OFF Reset/ON 25 2 1 Overload relays 27.5 102 39 45 30 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical ZB32 45 85 90.5 3.8 35 75 40.5 M4 ZB65 60 86 112 4.7 50 75 47 M5 Overload relays Overload relays 1.2 Overload relays 1 ZB65 40 172 OFF Reset/ON 35 7.5 46.5 96.5 132 60 ZB150 90 160 70 OFF Reset/ON 44 74 91 277 156 170 150 7 5 134 16.5 95 100 118 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 31 1.2 Overload relays Overload relays, CT-operated overload relays 1 Overload relays ZB150-50/KK OFF Reset/ON 100 7 121 74 7 5 63 16.5 129 95 134 99 118 Z5 overload relays greater than 150A Z5-.../FF250 OFF Reset/ON 121 110 96 144 48 25 94 169 144 74 7 111 7 5 11 16.5 128 Current transformer-operated overload relays ZW7-… 1.5 7.5 4.3 55 85 55 44 26 26 44 33 71 21 8 185 M4 185 159 172 – 250 200 65 71 65 90° 27 32 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 90° 90° Reset/ON Overload relays Electronic overload relays 1.2 Electronic overload relays 1 ZEB12 ZEB32 117 139.5 76 43 79 161 143 70 34 97.5 103 33.2 108 40.5 103 33.2 45 108 40.5 45 ZEB65-45 ZEB65-100 146.1 146.1 132.5 213.6 57.5 107 184 87 57.5 132.5 5 33.2 40.5 45 103 108 38.6 46.2 128.2 136.3 55 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 33 1.2 Overload relays Electronic overload relays 1 Electronic overload relays ZEB150-100 111.8 175 160 289.1 145.4 85 90 38.6 132.4 63.2 140.5 116 104.8 51.7 ZEB150-100/KK 41 132.4 38.6 140.5 46.1 56 34 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.2 Overload relays Thermistor overload relays for machine protection, electronic overload relays Thermistor overload relays for machine protection, electronic overload relays Current sensors 1 ZEB-XCT600 206 89.2 127 193.5 234.2 165.1 106.1 190.5 205.4 ZEB-XCT300 ZEB-XCT1000 ZEB-XCT1500 330.2 188.9 304.6 317 10.1 83.5 383.5 Ø 73.2 108 108 EMT6 thermistor overload relays for machine protection External reset button EMT6… M22-DZ-B M22-DZ-X 100 78 19 3.2 102 24.1 _> 3 Ø 29.5 2.5 22.5 8 22.3 2–5 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 35 C441 overload and monitoring relay Product description C441 overload and monitoring relay 1.2 C441 overload and monitoring relay Features and benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog number selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical data and specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 38 41 42 43 48 60 C441 overload and monitoring relay Product description Eaton’s Motor Insight, the first product in the Intelligent Power Control Solutions family, is a highly configurable motor, load and line protection device with power monitoring, diagnostics and flexible communications allowing the customer to save energy, optimize their maintenance schedules and configure greater system protection, thus reducing overall costs and downtime. Motor Insight is available in either a line-powered or 120 Vac control powered design, capable of monitoring voltages up to 660 Vac. Each of these units is available in a 1–9 amp or a 5–90 amp FLA model. With external CTs, Motor Insight can protect motors up to 540 amps FLA. Available add-on accessories include communication modules for Modbus RTU, DeviceNet, PROFIBUS, Modbus TCP, EtherNet/IP and HTTP web services all with I/O options. For ease-of-use and operator safety, Motor Insight offers a remote display that mounts easily with two 30 mm knockouts. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 37 1.2 C441 overload and monitoring relay Features and benefits 1 Features and Benefits Benefits Features Size/Range Broad FLA range of 1–540A Selectable trip class (5–30) Four operating voltage options Line-powered from 240 Vac, 480 Vac, 600 Vac Control-powered from 120 Vac Motor Control Two output relays One B300 Form C fault relay and one B300 ground fault shunt relay Other relay configurations are available, including one Form A and one Form B SPST (fault and auxiliary relays) allowing programmable isolated relay behavior and unique voltages One external remote reset terminal Trip status indicator Motor Protection Thermal overload Jam protection Current imbalance Current phase loss Ground fault Phase reversal Line Protection Over voltage Under voltage Voltage imbalance Voltage phase loss Monitoring Capabilities Current—average and phase rms Voltage—average and phase rms Power—motor kW Power factor Frequency Thermal capacity Run hours Ground fault current Current imbalance % Voltage imbalance % Motor starts Motor run hours Options Type 1, 12 remote display Type 3R remote display kit Communication modules Modbus Modbus with I/O DeviceNet with I/O PROFIBUS with I/O Modbus TCP with I/O EtherNet/IP with I/O Reliability and Improved Uptime Advanced diagnostics allows for quick and accurate identification of the root source of a motor, pump or power quality fault; reducing troubleshooting time and the loss of productivity, reducing repeat faults due to misdiagnosis, and increasing process output and profitability Provides superior protection of motors and pumps before catastrophic failure occurs Increases profitability with greater process uptime and throughput, reduced costs per repair, reduced energy consumption and extended equipment life Adjustments to overload configuration can be made at any time Safety IP20 rated terminal blocks Terminal blocks are set back from the display to reduce operator shock hazard Remote display (optional) does not require that the operator open the panel to configure the device Load Protection Under current Low power (kW) High power (kW) Standards and Certifications cULus listed NKCR, NKCR7, 508 UL® 1053 applicable sections for ground fault detection 38 CSA® certified (Class 3211-02) CE NEMA® IEC EN 60947-4-1 RoHS CCC AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Flexibility Communications modules Offered in a variety of configurations External snap-on modules provide support for multiple communications protocols Advanced power, voltage and current monitoring capabilities Communications modules and remote display can be used simultaneously Highly configurable fault and reset characteristics for numerous applications Fully programmable isolated fault and auxiliary relays Ease of Use Bright LED display with easy-to-understand setting and references Powered from line voltage or 120 Vac control power Remote display powered from base unit Full word descriptions and units on user interface C441 overload and monitoring relay Features and benefits 1.2 Advanced Overload Education Description 1 Motor Insight Protection Definition Source Result Overload is a condition in which current draw to a motor exceeds 115% of the full load amperage rating over a period of time for an inductive motor. An increase in the load or torque that is being driven by the motor. Increase in current draw. Current leads to heat and insulation breakdown, which can cause system failure. Additionally, an increase in current can increase power consumption and waste valuable energy. Thermal trip behavior is defined by UL, CSA and IEC standards. The motor attempts to drive the load, which has more resistive force due to the mechanical interference. In order to drive the load, the motor draws an abnormal amount of current, which can lead to insulation breakdown and system failure. Provides a configurable Jam setting that is active during “motor run state” to avoid nuisance trips. An undetected ground fault can burn through multiple insulation windings, ultimately leading to motor failure. Motor Insight has ground fault protection capability down to 0.15 amps estimated from the existing three-phase CTs using the residual current method. That is, the three-phase current signals should sum to zero unless a ground fault (GF) condition is present. In the case of a GF, Motor Insight can alarm, trip the starter, or trip an alternative relay that can be used to shunt trip a breaker or light up a warning light. GF current can also be monitored in real-time through the advanced monitoring capabilities. Motor Protection Thermal overload A low voltage supply to the motor would cause the current to go high to maintain the power needed. Trip class is settable from 5–30 by 1 Provides power factor monitoring and low voltage protection features. A poor power factor would cause above normal current draw. Jam Ground fault Jam is similar to thermal overload in that it is a current draw on the motor above normal operating conditions. A line to ground fault. Mechanical stall, interference, jam or seizure of the motor or motor load. A current leakage path to ground. Trip Threshold 150–400% of FLA. Trip Delay 1–20 seconds. Note: GF settable thresholds vary with motor FLA. 0.15 amps may not be available in all cases. Provides two protection settings that address this problem. The user can choose to set current imbalance thresholds or voltage imbalance thresholds, each of which can trip the starter. Additionally, both of these may be monitored through Motor Insight’s advanced monitoring capabilities, allowing the customer to notice in realtime when and where a condition is present. Imbalanced phases (voltage and current) Uneven voltage or currents between phases in a three-phase system. When a three-phase load is powered with Imbalanced voltage causes large a poor quality line, the voltage per phase imbalanced currents and as a result this can lead to motor stator windings being may be imbalanced. overloaded, causing excessive heating, reduced motor efficiency and reduced insulation life. Phase loss—current (single-phasing) One of the three-phase current is not present. Multiple causes, loose wire, improper wiring, grounded phase, open fuse, and so on. Phase rotation (phase-reversal) Improper wiring, leading to phases being A miswired motor. Inadvertent phaseconnected to the motor improperly. reversal by the utility. Phase-reversal can cause unwanted directional rotation of a motor. In the event that the load attached to the motor can only be driven in one direction, the result could be significant mechanical failure and/or injury to an operator. Configurable phase protection, allowing the user to define the phase sequencing intended for that application. If no phase sequence is required, the user has the ability to disable this feature. Frequency variance When line frequency is inconsistent. Variations in frequency can cause increases in losses, decreasing the efficiency of the motor. In addition, this can result in interference with synchronous devices. Advanced monitoring capabilities allow the user to monitor frequency in real-time. Malfunctioning alternator speed regulator, or poor line quality caused by an overload of a supply powered by individual sources. Single-phasing can lead to unwanted Fixed protective setting that takes the motor vibrations in addition to the results starter offline if a phase drops below of imbalanced phases as listed above. 60% of the other two phases. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 39 1.2 C441 overload and monitoring relay Features and benefits 1 Advanced Overload Education, continued Description Motor Insight Protection Definition Source Result Under current or low power Average rms current provided to the motor falls below normal operating conditions. Under current is usually associated with a portion of the user’s load disappearing. Examples of this would be a broken belt, a dry-pump (low suction head) or a dead-headed centrifugal pump. If under current goes undetected, a mechanical failure can and has occurred. In the case of a pump, running a pump dry or running a pump in a dead-headed condition can cause excessive heating, damaging expensive seals and breaking down desired fluid properties. Motor Insight has two protection settings to detect this: under current and low power. Low power is a more consistent way of ensuring detection as power is linear with motor load, where as current is not. An unloaded motor may draw 50% of its rated current, but the power draw will be less than 10% of rated power due to a low power factor. High power The motor load is drawing more power than it should at normal operating conditions. This is typical of batch processing applications where several ingredients flow into a mixer. When a substance’s consistency changes and viscosity increases from what is expected, the motor may use more power to blend the mixture. Out-of-tolerance conditions can be detected using the High Power and Low Power settings. If a high-power fault goes undetected, the result may be a batch of material that does not meet specification. Monitors the three-phase real power. If the real power value is estimated above the set threshold for the set length of time, a fault is detected and the overload will trip the starter. Additionally, power can be monitored in real-time. Over voltage When the line voltage to the motor exceeds the specified rating. Poor line quality. An over voltage condition leads to a lower than rated current draw and a poor power factor. A trip limit of 110% of rated voltage is recommended. Over voltage can also lead to exceeding insulation ratings. Monitors the maximum rms value of the three-phase voltages. If the rms value rises above the set threshold for the set length of time, a fault is detected and the overload can trip the starter or send and display an alarm of the condition. All line-related faults have an “alarm-notrip” mode. Under voltage When the line voltage to the motor is below the specified rating. Poor line quality. An under voltage condition leads to excessive current draw. This increases the heating of the motor windings and can shorten insulation life. A trip limit set to 90% of rated voltage is recommended. Monitors the minimum rms value of the three-phase voltages. If the rms value drops below the set threshold for the set length of time, a fault is detected and the overload can trip the starter or send and display an alarm of the condition. All line-related faults have an “alarm-no-trip” mode. Power-up delay Allows for starting motors and loads in a deliberate fashion. When there is a power failure, or power cycle, multiple loads come online simultaneously. Multiple loads starting simultaneously can cause sags affecting the operation of devices that may prevent successful startup. Configurable to delay closing the fault relay on power-up. For each Motor Insight controlling a motor, a different setting can be programmed, helping to maintain the integrity of your line power. Load Protection Line Protection If power is lost to a motor driving a pump, it may be necessary to delay a restart to allow the pump to come to a complete stop to prevent starting a motor during backspin. 40 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical C441 overload and monitoring relay Catalog number selection 1.2 Catalog Number Selection 1 Motor Insight Overload Relays C441 B A NOUI Device Type C441 = Motor Insight overload relay Overload Relay Power Source Voltage B = 240 Vac (170–264 Vac) C = 480 Vac (323–528 Vac) D = 600 Vac (487–660 Vac) Blank = 120 Vac control power (170–660 Vac) Overload Relay Current Rating A = 1–9A (1–540A refer to Page 42 ) B = 5–90A (5–90A refer to Page 42 ) 0109 = 120 Vac control power (0–660 Vac, 1–9A) 0590 = 120 Vac control power (0–660 Vac, 5–90A) Internal User Interface Blank = With user interface (line powered models) NOUI = Without user interface (120 Vac control models) Motor Insight Overload Relays—Communications Modules and Accessory Types C441 K Device Type C441 = Motor Insight overload relay Communication Module DeviceNet module 4IN/2OUT 120 Vac DeviceNet module 4IN/2OUT 24 Vdc Modbus RTU module Modbus RTU module 4IN/2OUT 120 Vac Modbus RTU module 4IN/2OUT 24 Vdc PROFIBUS module 4IN/2OUT 120 Vac Modbus TCP / EtherNet/IP module 4IN/2OUT 120 Vac S = PROFIBUS module 4IN/2OUT 24 Vdc T = Modbus TCP / EtherNet/IP module 4IN/2OUT 24 Vdc Accessory Type 1 = Type 1 and 12 remote mounted display 3 = Type 3R kit for remote display CMP1 = Conversion plate K L M N P Q R = = = = = = = AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 41 1.2 C441 overload and monitoring relay Product selection 1 Product Selection Motor Insight Motor Insight Power Source Monitoring Range Current Range Catalog Number 240 Vac (170–264) 170–264 Vac 1–9A C441BA 5–90A C441BB 1–9A C441CA 5–90A C441CB 1–9A C441DA 5–90A C441DB 1–9A C4410109NOUI 5–90A C4410590NOUI 480 Vac (323–528) 323–528 Vac 600 Vac (489–660) 489–660 Vac 120 Vac (93.5–132) 170–660 Vac Motor Insight CT Multiplier and Wire Wrap Schedule Motor FLA Catalog Number Ŀ Number of Loops Number of Conductors Through CT Primary CT Multiplier Setting External CT Kit Catalog Number ŀ Current Range: 5–90A C441_B and C4410590NOUI 5–22.5A 3 4 4 — 6.67–30A 2 3 3 — 10–45A 1 2 2 — 20–90A 0 1 1 — 1–5A 1 2 2 — 2–9A 0 1 1 — Current Range: 1–9A C441_A and C4410109NOUI 60–135A 0 1 150–(150:5) C441CTKIT150 120–270A 0 1 300–(300:5) C441CTKIT300 240–540A 0 1 600–(600:5) C441CTKIT600 Notes Ŀ Underscore indicates Operating Voltage Code required. Operating Voltage Codes: Code Voltage B 240 Vac C 480 Vac D 600 Vac120 Vac Control Power ŀ 42 Any manufacturer’s CTs may be used. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical C441 overload and monitoring relay Accessories 1.2 Accessories 1 Modbus Communication Module The Motor Insight Modbus Communication Module is a side-mounted device providing Modbus communication capability to the Motor Insight overload relay. The Modbus Communication Module with I/O provides communication, monitoring and control for the Motor Insight overload relay. Features and Benefits The Modbus communication module is capable of baud rates up to 115K The Modbus address and baud rate configuration can be easily changed using the Motor Insight user interface (C441M only) Modbus address and baud rate are set via convenient DIP switches (C441N and C441P); LEDs are provided to display Modbus traffic Configuration with common Modbus configuration tools Terminals Unique locking mechanism provides for easy removal of the terminal block with the field wiring installed Each terminal is marked for ease of wiring and troubleshooting Selectable I/O assemblies 4IN/2OUT Signal types include 24 Vdc I/O and 120 Vac I/O Each I/O module is optically isolated between the field I/O and the network adapter to protect the I/O and communication circuits from possible damage due to transients and ground loops Input Module features a user-definable input debounce, which limits the effects of transients and electrical noise Output Module supports a user-definable safe state for loss of communication; hold last state, ON or OFF Modbus Communication Module Description I/O Catalog Number Modbus Module Modbus Communication Module None C441M Modbus with I/O Module Modbus Communication Module 4IN/2OUT 120 Vac C441N Modbus Communication Module 4IN/2OUT 24 Vdc C441P AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 43 1.2 C441 overload and monitoring relay Product selection 1 DeviceNet Communication Modules The DeviceNet Features and Benefits Communication Module Communication to provides monitoring and DeviceNet uses only one control for the Motor Insight DeviceNet MAC ID overload relay from a single Configuration DeviceNet node. These DeviceNet MAC ID and modules also offer convenient Baud rate are set via I/O in two voltage options, convenient DIP switches 24 Vdc and 120 Vac. with an option to set from the network Advanced configuration available using common DeviceNet tools Terminals Unique locking mechanism provides for easy removal of the terminal block with the field wiring installed Each terminal is marked for ease of wiring and troubleshooting DeviceNet Module 44 Selectable I/O assemblies 4IN/2OUT Signal types include 24 Vdc I/O and 120 Vac I/O Each I/O module is optically isolated between the field I/O and the network adapter to protect the I/O and communication circuits from possible damage due to transients and ground loops DeviceNet Modules Description I/O Catalog Number DeviceNet Communication Module 120 Vac C441K DeviceNet Communication Module 24 Vdc C441L AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Input Module features a user-definable input debounce, which limits the effects of transients and electrical noise Output Module supports a user-definable safe state for loss of communication; hold last state, ON or OFF Combined status LED C441 overload and monitoring relay Accessories PROFIBUS Communication Module The Motor Insight PROFIBUS Communication Module is a side-mounted device providing PROFIBUS communication capability to the Motor Insight overload relay. The PROFIBUS Communication Module with I/O provides communication, monitoring and control for the Motor Insight overload relay. PROFIBUS with I/O Module 1.2 1 Features and Benefits The PROFIBUS communication module is capable of baud rates up to 12 Mb PROFIBUS address is set via convenient DIP switches (C441Q and C441S); LEDs are provided to display PROFIBUS status Intuitive configuration with common PROFIBUS configuration tools Terminals Unique locking mechanism provides for easy removal of the terminal block with the field wiring installed Each terminal is marked for ease of wiring and troubleshooting Selectable I/O assemblies 4IN/2OUT Signal types include 24 Vdc I/O and 120 Vac I/O Each I/O module is optically isolated between the field I/O and the network adapter to protect the I/O and communication circuits from possible damage due to transients and ground loops Input Module features a user-definable input debounce, which limits the effects of transients and electrical noise Output Module supports a user-definable safe state for loss of communication; hold last state, ON or OFF PROFIBUS Communication Module I/O Catalog Number PROFIBUS Communication Module 4IN/2OUT 120 Vac C441S PROFIBUS Communication Module 4IN/2OUT 24 Vdc C441Q Description AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 45 1.2 C441 overload and monitoring relay Accessories 1 Ethernet Communication Module The Motor Insight Ethernet Communication Module is a side-mounted device providing both Modbus TCP and EtherNet/IP communication capabilities with built-in HTTP web services to the Motor Insight overload relay. The Ethernet Communication Module with I/O provides communication, monitoring and control for the Motor Insight overload relay. Ethernet with I/O Module Features and Benefits Supports Modbus TCP or EtherNet/IP in a single device Contains internal embedded switch which provides two Ethernet ports allowing linear or ring network configurations Embedded web services allow for simple configuration and monitoring through Internet Explorer IP Address is set via convenient DIP Switches located on the device Ethernet Communication Module Description 46 Terminals Unique locking mechanism provides for easy removal of the terminal block with the field wiring installed Each terminal is marked for ease of wiring and troubleshooting Selectable I/O assemblies 4IN/2OUT Signal types include 24 Vdc I/O and 120 Vac I/O I/O Catalog Number Modbus TCP / EtherNet/IP Communication Module 4IN/2OUT 120 Vac C441R Modbus TCP / EtherNet/IP Communication Module 4IN/2OUT 24 Vdc C441T AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Each I/O module is optically isolated between the field I/O and the network adapter to protect the I/O and communication circuits from possible damage due to transients and ground loops Input Module features a user-definable input debounce, which limits the effects of transients and electrical noise Output Module supports a user-definable safe state for loss of communication; hold last state, ON or OFF C441 overload and monitoring relay Accessories Type 3R Kit with Remote Display Mounted Inside Features and Benefits Motor Insight offers several accessories for the Remote display unit: customer’s ease of use Same user interface as and safety: the overload relay Types 1 and 12 remote Enhanced operator display safety—operator can Type 3R remote display kit configure the overload without opening the Mounting plate adapter enclosure door 1.2 1 Type 3R kit mounts with standard 30 mm holes Mounting plate for retrofit in existing installations Type 3R Kit with Remote Display Mounted Inside Description Catalog Number C4411 Remote display Types 1 and 12 (UL 508) C4411 C4413 Type 3R kit for remote display (UL 508) C4413 Conversion plate (not shown) C441CMP1 Communication Cables The Remote Display requires a communication cable to connect to the Motor Insight overload relay: Communication Cable Lengths Length in Inches (meters) Catalog Number 9.8 (0.25) D77E-QPIP25 39.4 (1.0) D77E-QPIP100 78.7 (2.0) D77E-QPIP200 118.1 (3.0) D77E-QPIP300 Current Transformer Kits Description Catalog Number Three 150:5 CTs to be used with Motor Insight C441CTKIT150 Three 300:5 CTs to be used with Motor Insight C441CTKIT300 Three 600:5 CTs to be used with Motor Insight C441CTKIT600 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 47 1.2 C441 overload and monitoring relay Technical data and specifications 1 Technical Data and Specifications Motor Insight Description Specification C441B_ C441C_ C441D_ C441_ _ _ _NOUI Electrical Ratings Feature Range Operating voltage (threephase) and frequency 170–264 Vac 50/60 Hz 323–528 Vac 50/60 Hz 489–660 Vac 50/60 Hz 170–660 Vac 50/60 Hz Selectable Selectable Selectable Selectable C441_A and C4410109NOUI 1–9A C441_B and C4410590NOUI 5–90A Up to 540A with external CTs Refer to Page 42 for CT multiplier and wire wrap schedule. Trip Class 5–30 FLA Range Up to 540A with external CTs Refer to Page 42 for CT multiplier and wire wrap schedule. Up to 540A with external CTs Refer to Page 42 for CT multiplier and wire wrap schedule. Monitoring Capabilities Feature Value Current Per phase rms (1A, 1B, 1C), 2% accuracy Average rms, 2% accuracy Imbalance percent (0–100%) Ground fault current, 10% accuracy Per phase rms (1A, 1B, 1C), 2% accuracy Average rms, 2% accuracy Imbalance percent (0–100%) Ground fault current, 10% accuracy Per phase rms (1A, 1B, 1C), 2% accuracy Average rms, 2% accuracy Imbalance percent (0–100%) Ground fault current, 10% accuracy Per phase rms (1A, 1B, 1C), 2% accuracy Average rms, 2% accuracy Imbalance percent (0–100%) Ground fault current, 10% accuracy Voltage Per phase rms (1A, 1B, 1C), 2% accuracy Average rms, 2% accuracy Imbalance percent (0–100%) Per phase rms (1A, 1B, 1C), 2% accuracy Average rms, 2% accuracy Imbalance percent (0–100%) Per phase rms (1A, 1B, 1C), 2% accuracy Average rms, 2% accuracy Imbalance percent (0–100%) Per phase rms (1A, 1B, 1C), 2% accuracy Average rms, 2% accuracy Imbalance percent (0–100%) Power Motor kW, 5% accuracy Motor power factor, inductive 0–1.0, 1% accuracy Motor kW, 5% accuracy Motor power factor, inductive 0–1.0, 1% accuracy Motor kW, 5% accuracy Motor power factor, inductive 0–1.0, 1% accuracy Motor kW, 5% accuracy Motor power factor, inductive 0–1.0, 1% accuracy Thermal capacity 0% cold, 100% trip 0% cold, 100% trip 0% cold, 100% trip 0% cold, 100% trip Motor run hours 0–65,535 hours 0–65,535 hours 0–65,535 hours 0–65,535 hours Frequency 47–63 Hz, 1% accuracy 47–63 Hz, 1% accuracy 47–63 Hz, 1% accuracy 47–63 Hz, 1% accuracy Thermal overload setting 1.05 x FLA: Does not trip 1.15 x FLA: Overload trip 1.05 x FLA: Does not trip 1.15 x FLA: Overload trip 1.05 x FLA: Does not trip 1.15 x FLA: Overload trip 1.05 x FLA: Does not trip 1.15 x FLA: Overload trip Feature Range Motor Protection Fault Delay Setting Jam 150–400% of motor FLA, OFF 150–400% of motor FLA, OFF 150–400% of motor FLA, OFF 50–400% of motor FLA, OFF 1–20 seconds Current imbalance 1–30%, OFF 1–30%, OFF 1–30%, OFF 1–30%, OFF 1–20 seconds Current phase loss Fixed threshold 60% Fixed threshold 60% Fixed threshold 60% Fixed threshold 60% 1–20 seconds C441_A and C4410109NOUI 1–9A 0.3–2.0A with one pass through the CTs Ŀ 0.3–2.0A with one pass through the CTs Ŀ 0.3–2.0A with one pass through the CTs Ŀ 0.3–2.0A with one pass through the CTs Ŀ <150%, 1–60 seconds >150%, 2 seconds >250%, 1 second C441_B and C4410590NOUI 5–90A 3.0–20A with one pass through the CTs Ŀ 3.0–20A with one pass through the CTs Ŀ 3.0–20A with one pass through the CTs Ŀ 3.0–20A with one pass through the CTs Ŀ <150%, 1–60 seconds >150%, 2 seconds >250%, 1 second OFF = Ignore, 1 = ACB, 2 = ABC OFF = Ignore, 1 = ACB, 2 = ABC Ground fault current Phase reversal OFF = Ignore, 1 = ACB, 2 = ABC minutes, auto ŀ Fault reset delay 2–500 Fault reset attempts 0–4 restarts allowed or automatic reset ŀ OFF = Ignore, 1 = ACB, 2 = ABC 2–500 minutes, auto ŀ 0–4 restarts allowed or automatic reset ŀ ŀ 2–500 minutes, auto ŀ 0–4 restarts allowed or automatic reset ŀ 0–4 restarts allowed or automatic reset ŀ 2–500 minutes, auto Notes Ŀ Lower levels are achievable with multiple passes. ŀ Motor fault reset characteristics can be programmed as a group or for motor overloads only. Reference the user manual for more detailed information. 48 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical C441 overload and monitoring relay Technical data and specifications 1.2 Motor Insight, continued Description Specification C441B_ 1 C441C_ C441D_ C441_ _ _ _NOUI 50–90% of motor FLA 50–90% of motor FLA 50–90% of motor FLA Load Protection Feature Range Under current 50–90% of motor FLA Fault Delay Setting 1–60 seconds Low power (kW) 20–80% of rated kW 20–80% of rated kW 20–80% of rated kW 20–80% of rated kW 1–60 seconds High power (kW) 50–110% of rated kW 50–110% of rated kW 50–110% of rated kW 50–110% of rated kW 1–60 seconds Load reset delay 2–500 minutes, auto 2–500 minutes, auto 2–500 minutes, auto 2–500 minutes, auto Load reset attempts 0–4, auto 0–4, auto 0–4, auto 0–4, auto Supply Protection Feature Range Over voltage 170–264 Vac 323–528 Vac 489–660 Vac 0–660 Vac Fault Delay Setting 1–20 seconds Under voltage 170–264 Vac 323–528 Vac 489–660 Vac 0–660 Vac 1–20 seconds Voltage imbalance 1–20% imbalance 1–20% imbalance 1–20% imbalance 1–20% imbalance 1–20% imbalance Restart delay setting 1–500 seconds 1–500 seconds 1–500 seconds 1–500 seconds 1–500 seconds Radiated emissions IEC 60947-4-1—Table 15, EN 55011 (CISPIR 11) Group 1, Class A 30–1000 mHz 30–1000 mHz 30–1000 mHz 30–1000 mHz 30–1000 mHz Conducted emissions IEC 60947-4-1—Table 14, EN 55011 (CISPIR 11) Group 1, Class A 0.15–30 mHz 0.15–30 mHz 0.15–30 mHz 0.15–30 mHz 0.15–30 mHz ESD immunity IEC 60947-4-1 (Table 13) ±8 kV air, ±4 kV contact ±8 kV air, ±4 kV contact ±8 kV air, ±4 kV contact ±8 kV air, ±4 kV contact ±8 kV air, ±4 kV contact Radiated immunity IEC 60947-4-1 10 V/m 80–1000 mHz 80% amplitude modulated 1 kHz sine wave 10 V/m 80–1000 mHz 80% amplitude modulated 1 kHz sine wave 10 V/m 80–1000 mHz 80% amplitude modulated 1 kHz sine wave 10 V/m 80–1000 mHz 80% amplitude modulated 1 kHz sine wave 10 V/m 80–1000 mHz 80% amplitude modulated 1 kHz sine wave Conducted immunity IEC 60947-4-1 140 dBuV (10V rms) 150 kHz–80 mHz 140 dBuV (10V rms) 150 kHz–80 mHz 140 dBuV (10V rms) 150 kHz–80 mHz 140 dBuV (10V rms) 150 kHz–80 mHz 140 dBuV (10V rms) 150 kHz–80 mHz Fast transient immunity IEC 60947-4-1 (Table 13) IEC 61000-4-4 ±2 kV using direct method ±2 kV using direct method ±2 kV using direct method ±2 kV using direct method ±2 kV using direct method Surge immunity IEC 60947-4-1 (Table 13) IEC 61000-4-4 Three-phase power inputs: ±2 kV line-to-line (DM) ±4 kV line-to-ground (CM) Three-phase power inputs: ±2 kV line-to-line (DM) ±4 kV line-to-ground (CM) Three-phase power inputs: ±2 kV line-to-line (DM) ±4 kV line-to-ground (CM) Three-phase power inputs: ±2 kV line-to-line (DM) ±4 kV line-to-ground (CM) Three-phase power inputs: ±2 kV line-to-line (DM) ±4 kV line-to-ground (CM) IEC 61000-4-5 Class 3 User IO and communication lines: ±1 kV line-to-line (DM) ±2 kV line-to-ground (CM) IEC 61000-4-5 Class 3 User IO and communication lines: ±1 kV line-to-line (DM) ±2 kV line-to-ground (CM) IEC 61000-4-5 Class 3 User IO and communication lines: ±1 kV line-to-line (DM) ±2 kV line-to-ground (CM) IEC 61000-4-5 Class 3 User IO and communication lines: ±1 kV line-to-line (DM) ±2 kV line-to-ground (CM) IEC 61000-4-5 Class 3 User IO and communication lines: ±1 kV line-to-line (DM) ±2 kV line-to-ground (CM) Voltage variations immunity IEC 60947-4-1 30% dip, at 100 ms 60% dip at 10 ms >95% interrupt at 5 ms 30% dip, at 100 ms 60% dip at 10 ms >95% interrupt at 5 ms 30% dip, at 100 ms 60% dip at 10 ms >95% interrupt at 5 ms 30% dip, at 100 ms 60% dip at 10 ms >95% interrupt at 5 ms 30% dip, at 100 ms 60% dip at 10 ms >95% interrupt at 5 ms Electromagnetic field IEC 60947-4-1 (Table 13) IEC 61000-4-3 10 V/m 10 V/m 10 V/m 10 V/m 10 V/m Ground fault UL 508, UL 1053 Sections 21 and 27 UL 508, UL 1053 Sections 21 and 27 UL 508, UL 1053 Sections 21 and 27 UL 508, UL 1053 Sections 21 and 27 UL 508, UL 1053 Sections 21 and 27 Electrical/EMC AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 49 1.2 C441 overload and monitoring relay Technical data and specifications 1 Motor Insight, continued Specification C441B_ Description C441C_ C441D_ C441_ _ _ _NOUI Environmental Ratings Feature Range Ambient temperature (operating) –4° to 122°F (–20° to 50°C) –4° to 122°F (–20° to 50°C) –4° to 122°F (–20° to 50°C) –4° to 122°F (–20° to 50°C) Ambient temperature (storage) –40° to 85°C –40° to 85°C –40° to 85°C –40° to 85°C Operating humidity 5% to 95% noncondensing 5% to 95% noncondensing 5% to 95% noncondensing 5% to 95% noncondensing Altitude (no derating) 2000m 2000m 2000m 2000m Shock (IEC 60068-2-27) 15G any direction 15G any direction 15G any direction 15G any direction Vibration (IEC 60068-2-6) 3G any direction 3G any direction 3G any direction 3G any direction Pollution degree per IEC 60947-1 3 3 3 3 Ingress protection IP20 IP20 IP20 IP20 Capacity Input, auxiliary contact and external reset terminals Terminal capacity 18–12 AWG 18–12 AWG 18–12 AWG 18–12 AWG Tightening torque 5.3 lb-in (0.6 Nm) 5.3 lb-in (0.6 Nm) 5.3 lb-in (0.6 Nm) 5.3 lb-in (0.6 Nm) Voltages Monitoring voltage 170–264 Vac 50/60Hz 323–528 Vac 50/60Hz 489–660 Vac 60Hz 0–660 Vac 50/60Hz Insulation voltage Ui (three-phase voltage) 600 Vac 600 Vac 600 Vac 600 Vac Insulation voltage Ui (control) 240 Vac 240 Vac 240 Vac 240 Vac Impulse withstand Uimp (main/control) 6 kV 6 kV 6 kV 6 kV 10 years 10 years 10 years 10 years B300 pilot duty 5A thermal continuous current 30A make 3.00A break at 120 Vac and 15A make 1.50A break at 240 Vac B300 pilot duty 5A thermal continuous current 30A make 3.00A break at 120 Vac and 15A make 1.50A break at 240 Vac B300 pilot duty 5A thermal continuous current 30A make 3.00A break at 120 Vac and 15A make 1.50A break at 240 Vac B300 pilot duty 5A thermal continuous current 30A make 3.00A break at 120 Vac and 30A make 1.50A break at 240 Vac Ŀ Isolated 120 Vac digital input IEC 61131-2 Section 5 Type 1 Isolated 120 Vac digital input IEC 61131-2 Section 5 Type 1 Isolated 120 Vac digital input IEC 61131-2 Section 5 Type 1 Isolated 120 Vac digital input IEC 61131-2 Section 5 Type 1 Trip Fault Fault Fault Fault Reset Ready Ready Ready Ready Autoreset Trip faulted/Ready flashing Trip faulted/Ready flashing Trip faulted/Ready flashing Trip faulted/Ready flashing 5W 5W 5W 5W Expected Life Mechanical/electrical Output Contact Ratings Two output relays One Form C SPDT (fault relay) One Form A SPST (ground fault relay) C441_ _ _ _NOUI models: One Form A SPST One Form B SPST External remote reset terminal Indications Power Consumption Maximum Options Remote display Type 1, 12 and Type 3R kit Type 1, 12 and Type 3R kit Type 1, 12 and Type 3R kit Type 1, 12 and Type 3R kit Communications modules Modbus, DeviceNet and PROFIBUS with I/O Modbus, DeviceNet and PROFIBUS with I/O Modbus, DeviceNet and PROFIBUS with I/O Modbus, DeviceNet and PROFIBUS with I/O Note Ŀ In this model, there are two isolated relays: one Form A and one Form B SPST. One is the fault relay, and one is a programmable auxiliary relay. 50 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.2 C441 overload and monitoring relay Technical data and specifications Motor Insight Short Circuit Ratings (North America CSA and UL) 1 Standard-Fault Short Circuit Data Overload FLA Range Maximum Operating Voltage Withstand Rating Maximum Fuse (RK5) Maximum Thermal-Magnetic Circuit Breaker 1–9A 264 Vac 5000A at 240 Vac 35A 35A 1–9A 1–9A 528 Vac 660 Vac 5000A at 480 Vac 5000A at 600 Vac 35A 35A 35A 35A Maximum Withstand Rating Maximum Fuse (RK5) Eaton Thermal-Magnetic Circuit Breaker Catalog Number C441BA 100 kA at 240 Vac 35A — 100 kA at 240 Vac — FDC3035L 100 kA at 480 Vac 35A — 100 kA at 480 Vac — FDC3035L 100 kA at 600 Vac 35A — 35 kA at 600 Vac — FDC3035L 35A — 35A — 35A — — FDC3035L — FDC3035L — FDC3035L C4410109NOUI C441BB 1–9A 660 Vac 5000A at 600 Vac 35A 35A 100 kA at 240 Vac 100 kA at 240 Vac 100 kA at 480 Vac 100 kA at 480 Vac 100 kA at 600 Vac 35 kA at 600 Vac 5–90A 264 Vac 10,000A at 240 Vac 350A 350A 100 kA at 240 Vac 350A — 100 kA at 240 Vac — KDC3350 5–90A 5–90A 5–90A 528 Vac 660 Vac 660 Vac 10,000A at 480 Vac 10,000A at 600 Vac 10,000A at 600 Vac 350A 350A 350A 350A 350A 350A C441CA 100 kA at 480 Vac 350A — 100 kA at 480 Vac — KDC3350 100 kA at 600 Vac 350A — 65 kA at 600 Vac — KDC3350 100 kA at 240 Vac 100 kA at 240 Vac 100 kA at 480 Vac 100 kA at 480 Vac 100 kA at 600 Vac 35 kA at 600 Vac 350A — 350A — 350A — — KDC3350 — KDC3350 — KDC3350 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical C441DA C441CB C441DB C4410590NOUI 51 1.2 C441 overload and monitoring relay Technical data and specifications 1 Line Powered Models Terminal Connection Diagram 18–12 AWG; Torque 5.3 lb-in/0.6 Nm B300 Pilot Duty Only Use 75C CU wire only 120 Vac NC L1 Ŀ L2 Ŀ L3 95 Ŀ NO 96 97 GF Shunt 98 15 16 Reset R1 R2 For C441BA, BB, CA, CB, DA and DB Terminal Connection Specifications Name Designation Input Description Line voltage L1, L2, L3 Line voltage Three-phase line voltage input L1, L2, L3 connections must correspond to the respective CT1, CT2, CT3 current leads Fault relay 95/96 96/97 (common) 97/98 B300 UL 508 Form C contact: 95/96 Contact opens when the unit is faulted or unpowered 97/98 Contact closes when the unit is faulted or unpowered GF shunt 15 16 B300 UL 508 Form A contact: Contact closes when a ground fault is active Reset input R1, R2 120 Vac Fault reset input IEC 61131-2 Type 1 Control Powered Models Terminal Connection Diagram 120 Vac NC L1 L2 L3 95 NO 96 97 Cntrl. Pwr. 98 X1 X2 120 Vac Reset R1 R2 For C4410109NOUI and C441059NOUI Terminal Connection Specifications Name Designation Input Description Line voltage L1, L2, L3 Line voltage Three-phase line voltage input L1, L2, L3 connections must correspond to the respective CT1, CT2, CT3 current leads Terminal provided for wiring control power transformer (9A maximum capacity) Control power X1, X2 110–120 Vac Control power option for C441_ _ _ _NOUI 50–60Hz (+10/–15%) Fault relay 95/96 For C441_ _ _ _NOUI, the fault relay and auxiliary relay are 96/97 (isolated) isolated and do not share a common. By default they will 97/98 behave like a Form C, but they can be programmed to act independently from one another. B300 UL 508 Form C contact: 95/96 Contact opens when the unit is faulted or unpowered 97/98 Contact closes when the unit is faulted or unpowered Can be programmed to act independently of the 95/96 only in the C441_ _ _ _NOUI models GF shunt This relay does not exist on the C441_ _ _ _NOUI models. Instead, this functionality is available in the fully programmable 97/98 auxiliary relay. 97/98 B300 UL 508 Form A contact: Contact closes when a ground fault is active Separate GF control can still be achieved by programming auxiliary relay 97/98 to act independently of the 95/96 relay Reset input R1, R2 120 Vac Fault reset input IEC 61131-2 Type 1 Note Ŀ No motor loads, 9A maximum. 52 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical C441 overload and monitoring relay Technical data and specifications 1.2 Modbus Communication Modules Description 1 Specification Electrical/EMC Radiated emissions IEC 60947-4-1—Table 15, EN 55011 (CISPIR 11) Group 1, Class A 30–1000 mHz Conducted emissions IEC 60947-4-1—Table 14, EN 55011 (CISPIR 11) Group 1, Class A 0.15–30 mHz ESD immunity IEC 60947-4-1 (Table 13) IEC 61000-4-2 ±8 kV air, ±4 kV contact Radiated immunity IEC 60947-4-1 10 V/m 80–1000 mHz 80% amplitude modulated 1 kHz sine wave Conducted immunity IEC 60947-4-1 140 dBuV (10V rms) 150 kHz–80 mHz Fast transient immunity IEC 60947-4-1 (Table 13) IEC 61000-4-4 ±2 kV using direct method Surge immunity IEC 60947-4-1 (Table 13) IEC 61000-4-5 Class 3 User IO and communication lines Ŀ : ±1 kV line-to-line (DM) ±2 kV line-to-ground (CM) Electromagnetic field 1 IEC 60947-4-1 (Table 13) IEC 61000-4-3 10 V/m Environmental Ratings Ambient temperature (operating) –20° to 50°C Ambient temperature (storage) –40° to 85°C Operating humidity 5 to 95% noncondensing Altitude (no derating) 2000m Shock (IEC 60068-2-27) 15G any direction Vibration (IEC 60068-2-6) 3G any direction Pollution degree per IEC 60947-1 3 Degree of protection IP20 Over voltage category per UL 508 III C441P 24 Vdc Input Nominal input voltage 24 Vdc Operating voltage 18–30 Vdc Number of inputs 4 Signal delay 5 ms (programmable to 65 sec) OFF-state voltage < 6 Vdc ON-state voltage > 18 Vdc Nominal input current 5 mA Isolation 1500V Terminal screw torque 7–9 in-lb 24 Vdc source current 50 mA Operating Voltage Range—DC Input Modules OFF State Transition Region ON State 0–6 Vdc 6–18 Vdc 18–30 Vdc C441N 120 Vac Input Nominal input voltage 120 Vac Operating voltage 80–140 Vac Number of inputs 4 OFF-state voltage < 30 Vac ON-state voltage > 80 Vac Nominal input current 15 mA Signal delay 1/2 cycle Isolation 1500V Terminal screw torque 7–9 in-lb Note Ŀ Relates to C441M only. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 53 1.2 C441 overload and monitoring relay Technical data and specifications 1 Modbus Communication Modules, continued Description Specification Operating Voltage Range—AC Input Modules OFF State Transition Region ON State 0–30 Vac 30–80 Vac 80–140 Vac Output Modules Nominal voltage 120 Vac 24 Vdc Number of outputs (2) 1NO Form A 1NO/NC Form C Relay OFF time 3 ms Relay ON time 7 ms Max. current per point Ŀ 5A (B300 rated) Electrical life 100,000 cycles Mechanical life 1,000,000 cycles DeviceNet Communication Modules Description Specification Electrical/EMC Radiated emissions IEC 60947-4-1—Table 15, EN 55011 (CISPIR 11) Group 1, Class A 30–1000 mHz Conducted emissions IEC 60947-4-1—Table 14, EN 55011 (CISPIR 11) Group 1, Class A 0.15–30 mHz ESD immunity IEC 60947-4-1 (Table 13) IEC 61000-4-2 ±8 kV air, ±4 kV contact Radiated immunity IEC 60947-4-1 10 V/m 80–1000 mHz 80% amplitude modulated 1 kHz sine wave Conducted immunity IEC 60947-4-1 140 dBuV (10V rms) 150 kHz–80 mHz Fast transient immunity IEC 60947-4-1 (Table 13) IEC 61000-4-4 ±2 kV using direct method Surge immunity IEC 60947-4-1 (Table 13) IEC 61000-4-5 Class 2 User IO and communication lines: ±1 kV line-to-line (DM) ±2 kV line-to-ground (CM) Electromagnetic field IEC 60947-4-1 Table 13, IEC 61000-4-3 10 V/m Environmental Ratings Ambient temperature (operating) –20° to 50°C Ambient temperature (storage) –40° to 85°C Operating humidity 5–95% noncondensing Altitude (no derating) 2000m Shock (IEC 60068-2-27) 15G any direction Vibration (IEC 60068-2-6) 3G any direction Pollution degree per IEC 60947-1 3 Degree of protection IP20 DeviceNet DeviceNet connections Group 2, polling, bit strobe, explicit, no UCMM DeviceNet baud rate 125K, 250K, 500K Note Ŀ Resistive current at 55°C ambient. 54 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical C441 overload and monitoring relay Technical data and specifications 1.2 DeviceNet Communication Modules, continued Description 1 Specification C441L 24 Vdc Input Nominal input voltage 24 Vdc Operating voltage 18–30 Vdc Number of inputs 4 Signal delay 5 ms (programmable to 65 sec) OFF-state voltage < 6 Vdc ON-state voltage > 18 Vdc Nominal input current 5 mA Isolation 250V Terminal screw torque 7–9 in-lb 24V source current 50 mA Operating Voltage Range—DC Input Modules OFF State Transition Region ON State 0–6 Vdc 6–18 Vdc 18–30 Vdc C441K 120 Vac Input Nominal input voltage 120 Vac Operating voltage 80–140 Vac Number of inputs 4 OFF-state voltage < 30 Vac ON-state voltage > 80 Vac Nominal input current 15 mA Signal delay 1/2 cycle Isolation 250V Terminal screw torque 7–9 in-lb Operating Voltage Range—AC Input Modules OFF State Transition Region ON State 0–30 Vac 30–80 Vac 80–140 Vac Output Modules Nominal voltage 120 Vac 24 Vdc Number of outputs (2) 1NO Form A 1NO/NC Form C Relay OFF time 3 ms Relay ON time 7 ms Max. current per point Ŀ 5A (B300 rated) Electrical life 100,000 cycles Mechanical life 1,000,000 cycles Note Ŀ Resistive current at 55°C ambient. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 55 1.2 C441 overload and monitoring relay Technical data and specifications 1 PROFIBUS Communication Modules Description Specification Electrical/EMC Radiated emissions IEC 60947-4-1—Table 15, EN 55011 (CISPIR 11) Group 1, Class A 30–1000 mHz Conducted emissions IEC 60947-4-1—Table 14, EN 55011 (CISPIR 11) Group 1, Class A 0.15–30 mHz ESD immunity IEC 60947-4-1 (Table 13) IEC 61000-4-2 ±8 kV air, ±4 kV contact Radiated immunity IEC 60947-4-1 Table 13, IEC 61000-4-3 10 V/m 80–1000 mHz 80% amplitude modulated 1 kHz sine wave Conducted immunity IEC 60947-4-1 140 dBuV (10V rms) 150 kHz–80 mHz Fast transient immunity IEC 60947-4-1 (Table 13) IEC 61000-4-4 ±2 kV using direct method Surge immunity IEC 60947-4-1 (Table 13) IEC 61000-4-5 Class 2 User IO and communication lines: ±1 kV line-to-line (DM) ±2 kV line-to-ground (CM) Environmental Ratings Ambient temperature (operating) –20° to 50°C Ambient temperature (storage) –40° to 85°C Operating humidity 5–95% noncondensing Altitude (no derating) 2000m Shock (IEC 60068-2-27) 15G any direction Vibration (IEC 60068-2-6) 3G any direction Pollution degree per IEC 60947-1 3 Degree of protection IP20 PROFIBUS PROFIBUS connections Group 2, polling, bit strobe, explicit, no UCMM PROFIBUS baud rate 9.6K, 19.2K, 45.45K, 93.75K, 187.5K, 500K, 1.5M, 3M, 6M, 12M C441Q 24 Vdc Input Nominal input voltage 24 Vdc Operating voltage 18–30 Vdc Number of inputs 4 Signal delay 5 ms (programmable to 65 sec) OFF-state voltage <6 Vdc ON-state voltage >10 Vdc Nominal input current 5 mA Isolation 1500V Terminal screw torque 7–9 in-lb 24V source current 50 mA 56 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical C441 overload and monitoring relay Technical data and specifications 1.2 PROFIBUS Communication Modules, continued Description 1 Specification Operating Voltage Range—DC Input Modules OFF State Transition Region ON State 0–6 Vdc 6–18 Vdc 18–30 Vdc C441S 120 Vac Input Nominal input voltage 120 Vac Operating voltage 80–140 Vac Number of inputs 4 OFF-state voltage < 20 Vac ON-state voltage > 70 Vac Nominal input current 15 mA Signal delay 1/2 cycle Isolation 1500V Terminal screw torque 7–9 in-lb Operating Voltage Range—AC Input Modules OFF State Transition Region ON State 0–30 Vac 30–80 Vac 80–140 Vac Output Modules Nominal voltage 120 Vac 24 Vdc Number of outputs (2) 1NO Form A 1NO/NC Form C Relay OFF time 3 ms Relay ON time 7 ms Max. current per point Ŀ 5A (B300 rated) Electrical life 100,000 cycles Mechanical life 1,000,000 cycles Note Ŀ Resistive current at 55°C ambient. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 57 1.2 C441 overload and monitoring relay Technical data and specifications 1 Ethernet (Modbus TCP / EtherNet/IP) Communication Modules Description Specification Electrical/EMC Radiated emissions IEC 60947-4-1, Table 15, EN 55011 (CISPIR 11) Group 1, Class A 30–1000 mHz Conducted emissions IEC 60947-4-1, Table 15, EN 55011 (CISPIR 11) Group 1, Class A 0.15–30 mHz ESD immunity IEC 60947-4-1 (Table 13) IEC 61000-4-2 ±8 kV air, ±4 kV contact Radiated immunity IEC 60947-4-1 (Table 13) IEC 61000-4-3 10 V/m 80–1000 mHz 80% amplitude modulated 1 kHz sine wave Conducted immunity IEC 60947-4-1 140 dBuV (10V rms) 150 kHz to 80 mHz Fast transient immunity IEC 60947-4-1 (Table 13) IEC 61000-4-4 ±2 kV using direct method Surge immunity IEC 60947-4-1 (Table 13) IEC 61000-4-5 Class 2 User IO and communication lines: ±1 kV line-to-line (DM) ±2 kV line-to-ground (CM) Environmental Ratings Ambient temperature (operating) –20° to 50°C Ambient temperature (storage) –40° to 85°C Operating humidity 5–95% noncondensing Altitude (no derating) 2000m Shock (IEC 60068-2-27) 15G any direction Vibration (IEC 60068-2-6) 3G any direction Pollution degree per IEC 60947-1 3 Degree of protection IP20 Ethernet Ethernet connections Integrated two-port switch with dual RJ45 Ethernet connections Ethernet type Ethernet 10/100 Mbs, AutoMDX, Auto Negotiation C441T 24 Vdc Input Nominal input voltage 24 Vdc Operating voltage 18–30 Vdc Number of inputs 4 Signal delay 5 ms (programmable to 65 sec) OFF-state voltage <6 Vdc ON-state voltage >18 Vdc Nominal input current 5 mA Isolation 1500V Terminal screw torque 7–9 in-lb 24V source current 50 mA 58 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical C441 overload and monitoring relay Technical data and specifications 1.2 Ethernet (Modbus TCP / EtherNet/IP) Communication Modules, continued Description 1 Specification Operating Voltage Range—DC Input Modules OFF State Transition Region ON State 0–6 Vdc 6–18 Vdc 18–30 Vdc C441R 120 Vac Input Nominal input voltage 120 Vac Operating voltage 80–140 Vac Number of inputs 4 OFF-state voltage < 30 Vac ON-state voltage > 80 Vac Nominal input current 15 mA Signal delay 1/2 cycle Isolation 1500V Terminal screw torque 7–9 in-lb Operating Voltage Range—AC Input Modules OFF State Transition Region ON State 0–30 Vac 30–80 Vac 80–140 Vac Nominal voltage 120 Vac 24 Vdc Number of outputs (2) 1NO Form A 1NO/NC Form C Relay OFF time 3 ms Relay ON time 7 ms Maximum current per point Ŀ 5A (B300 rated) Electrical life 100,000 cycles Mechanical life 1,000,000 cycles Note Ŀ Resistive current at 55°C ambient. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 59 1.2 C441 overload and monitoring relay Dimensions 1 Dimensions Approximate Dimensions in mm Motor Insight Overload Relay Terminal Ref. 97.0 84.1 5.1 4 Places 100.1 100.1 88.9 100.1 Mounting Dimension (4) 10-32 Dia. 17.5 3 Places 101.1 125.0 Motor Insight with Mounted DeviceNet, PROFIBUS or Modbus with I/O Communication Module 5.1 Terminal Ref. 97.0 84.1 100.1 88.9 100.1 100.1 83.1 Mounting Dimensions (4) 10-32 122.9 125.0 Dia. 17.5 3 Places 101.1 16.0 60 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical C441 overload and monitoring relay Dimensions 1.2 Approximate Dimensions in mm Motor Insight with Mounted Modbus Communication Module 5.1 4 Places 1 Terminal Ref. 97.0 84.1 48.0 88.9 100.1 100.1 100.1 Mounting Dimensions (4) 10-32 125.0 115.1 125.0 15.0 Dia. 101.1 17.5 3 Places Motor Insight Remote Display 2X ø 31.0 Hole in Panel 68.6 30.5 27.9 44.5 12 GA Max. Panel Thickness 116.8 99.1 25.4 15.2 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 61 1.2 C441 overload and monitoring relay Dimensions 1 Approximate Dimensions in mm Motor Insight Cover Assembly 44.5 33.0 111.8 35.6 Motor Insight 50.8 106.7 109.2 25.4 35.6 Motor Insight Conversion Plate 7.6 99.1 5.1 10.2 5.1 101.6 91.4 68.6 58.4 78.7 5.1 83.8 62 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1 PKZ and PKE motor-protective circuit-breakers Machinery and installation downtimes should be kept as short as possible. The PKZ fuseless motor-protective circuit-breakers combine short-circuit and overload protection in one device, allowing fast restart readiness. PKZM01, PKZM0, PKZM4 and PKE have the same accessories. Combines easily with DILM contactors and DS7 soft starters. Connecting PKE to SmartWire-DT® facilitates high data transparency. PKZM01 (up to 16 A) motor-protective circuit-breaker with pushbuttons ATEX • Motor-protective circuit-breaker in housing for protection types IP40 and IP65. • Integrated EMERGENCY STOP and EMERGENCY OFF pushbuttons reduce wiring. PKZM0 (up to 32 A) and PKZM4 (up to 65 A) motor-protective circuit-breakers with rotary handle • • • • Short-circuit proof up to at least 50 kA for easy engineering Trip-indicating auxiliary contact enables remote diagnosis High safety through application as main switch or repair and maintenance switch ATEX approval for protection of EEx e motors up to 65 A PKE (up to 65 A) motor-protective circuit-breakers with electronic wide-range overload protection • • • • • • High flexibility through plug-in trip block Wide current setting ranges enable only five trip blocks up to 65 A Precise and extremely long-term stable characteristic curves Individual supply through integrated current converter ATEX approval for protection of EEx e motors up to 65 A Adjustable tripping classes DC string circuit-breakers PKZ-SOL and DC switch-disconnectors P-SOL (up to 63 A) for installations • • • • • High string circuit-breaker flexibility due to wide current setting range Enclosed switch-disconnector for external mounting (IP65) Remote shutdown through optional secondary voltage and shunt trip Voltage up to 1000 V DC TÜV certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Motor-protective circuit-breakers Contents Motor-protective circuit-breaker PKZM01, PKZM0,PKZM4, PKE System overview PKZM01, PKZM0, PKZM4, PKE motor-protective circuit-breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 Ordering Motor-protective circuit-breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Motor-protective circuit-breakers for startercombinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Transformer-protective circuit-breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 PKE electronic motor-protective circuit-breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Standard auxiliary contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Auxiliary contacts, shunt releases, undervoltage release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Engineering Accessories for motor-protective circuit-breakers in enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Ordering Insulated enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Busbar adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motor feeder plugs, three-phase commoning links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Actuating voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 20 22 25 26 29 Engineering Motor-protective circuit-breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Characteristic curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Switching capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Technical data Motor-protective circuit-breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Auxiliary contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Dimensions PKZM01, PKZM0 motor-protective circuit-breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PKZM4 motor-protective circuit-breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC string circuit-breaker PKZ-SOL, DC switch-disconnectors P-SOL, SOL 39 40 45 46 Description DC switches P-SOL, PKZ-SOL, SOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Ordering DC switch-disconnector SOL, ready-to-install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 DC switch-disconnector P-SOL, open . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 DC string circuit-breaker PKZ-SOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Engineering Circuit P-SOL, PKZ-SOL Interior circuit SOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Characteristic curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Technical data DC switch-disconnectors P-SOL,SOL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 DC string circuit-breaker PKZ-SOL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Dimensions DC switches P-SOL, PKZ-SOL, SOL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1 1.3 1 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker System overview 1 8 6 7 7 7 3 2 5 4 7 3 5 7 Basic devices Add-on functions Motor-protective circuitbreaker PKZM01 Page 3 Motor-protective circuitbreaker PKZM0 Page 4 2 1 2 Motor-protective circuitbreakerwith wide-range overload protection 3 7 Page 10 Page 8 Motor-protective circuitbreaker PKZM4 Page 4 Standard auxiliary contacts Mounting accessories 4 Door coupling handles IP65 Page 20 Shunt release 6 Insulated enclosure Page 29 Current limiters 8 Page 16 Mounting/wiring AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Page 12 Page 22 5 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE 1.3 Ordering 1 PKZM01 Screw terminals Max. motor rating AC-3 L I> T Rated uninterrupted current Setting range Overload releases Shortcircuit releases Std. pack Information relevant for export to North America Motor-protective circuit-breakers, type “1”; and type “2” coordination – – – 0.16 0.1…0.16 2.2 PKZM01-0.16 278475 1 off Product Standards – PKZM01-0.25 278476 1 off 220 V 230 V 240 V P 380 V 400 V 415 V P 440 V P Iu Ir I rm kW kW kW A A A 0.06 0.06 0.25 0.16…0.25 3.5 Part no. Article no. Price See price list 0.06 0.09 0.12 0.4 0.25…0.4 5.6 PKZM01-0.4 278477 1 off 0.09 0.12 0.18 0.63 0.4…0.63 8.8 PKZM01-0.63 278478 1 off UL File No. UL CCN CSA File No. CSA Class No. NA Certification 0.12 0.25 0.25 1 0.63…1 14 PKZM01-1 278479 1 off Suitable for 0.25 0.55 0.55 1.6 1…1.6 22 PKZM01-1.6 278480 1 off See also 0.37 0.75 1.1 2.5 1.6…2.5 35 PKZM01-2.5 278481 1 off 0.75 1.5 1.5 4 2.5…4 56 PKZM01-4 278482 1 off 1.1 2.2 3 6.3 4…6.3 88 PKZM01-6.3 278483 1 off 2.2 4 4 10 6.3…10 140 PKZM01-10 278484 1 off 3 5.5 5.5 12 8…12 168 PKZM01-12 278485 1 off 4 7.5 9 16 10…16 224 PKZM01-16 283390 1 off 5.5 9 11 20 16…20 280 PKZM01-20 283383 1 off 5.5 12.5 12.5 25 20…25 350 PKZM01-25 288893 1 off Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification UL 508; CSA-C22.2 No.14; IEC609474-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified Branch circuits, or suitable for group installations Page 34 UL 508; CSA-C22.2 No.14; IEC/EN 609474-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified Notes 6 5 3 3 Accessories Page 3 Standard auxiliary contacts 10 5 Trip-indicating auxiliary contact 12 6 Shunt release, undervoltage release 29 Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 3 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker PKZM0, PKZM4 1 Screw terminals Circuit diagrams Max. motor rating AC-3 Rated uninterrupted current Setting range Overload releases Short-circuit releases 220 V 230 V 240 V P 380 V 400 V 415 V P 440 V 500 V 660 V 690 V P P P Iu Ir I rm kW kW kW kW kW A A A Motor-protective circuit-breakers, type “1” and type “2”coordination 1) – – – – 0.06 0.16 0.1…0.16 2.2 L I> – 0.06 0.06 0.06 0.12 0.25 0.16…0.25 3.5 0.06 0.09 0.12 0.12 0.18 0.4 0.25…0.4 5.6 0.09 0.12 0.18 0.25 0.25 0.63 0.4…0.63 8.8 0.12 0.25 0.25 0.37 0.55 1 0.63…1 14 0.25 0.55 0.55 0.75 1.1 1.6 1…1.6 22 0.37 0.75 1.1 1.1 1.5 2.5 1.6…2.5 35 0.75 1.5 1.5 2.2 3 4 2.5…4 56 1.1 2.2 3 3 4 6.3 4…6.3 88 2.2 4 4 4 7.5 10 6.3…10 140 3 5.5 5.5 5.5 11 12 8…12 168 4 7.5 9 9 12.5 16 10…16 224 5.5 9 11 12.5 15 20 16…20 280 5.5 12.5 12.5 15 22 25 20…25 350 7.5 15 15 22 30 32 25…32 448 T Motor-protective circuit-breakers, type “1” and type “2” coordination 1) 4 7.5 9 9 12.5 16 10…16 224 5.5 12.5 12.5 15 22 25 16…25 350 7.5 15 17.5 22 22 32 25…32 448 11 20 22 24 30 40 32…40 560 14 25 30 30 45 50 40…50 700 17 30 37 37 55 58 50…58 812 18.5 34 37 45 55 65 55…65 882 Circuit-breakers 2) For line and cable protection – – – – – 16 10…16 224 – – – – – 25 16…25 350 – – – – – 32 25…32 448 L I> T 4 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Part no. Article no. Price See price list Screw terminals on feed side, spring-loaded terminals on output side Part no. Price Article no. See price list PKZM0-0.16 072730 PKZM0-0.25 072731 PKZM0-0.4 072732 PKZM0-0.63 072733 PKZM0-1 072734 PKZM0-1.6 072735 PKZM0-2.5 072736 PKZM0-0,16-SC 229828 PKZM0-0,25-SC 229829 PKZM0-0,4-SC 229830 PKZM0-0,63-SC 229831 PKZM0-1-SC 229832 PKZM0-1,6-SC 229833 PKZM0-2.5-SC 229834 PKZM0-4 072737 PKZM0-6.3 072738 PKZM0-10 072739 PKZM0-12 278486 PKZM0-16 046938 PKZM0-4-SC 229835 PKZM0-6,3-SC 229836 PKZM0-10-SC 229837 PKZM0-12-SC 278487 PKZM0-16-SC 229838 PKZM0-20 046988 PKZM0-25 046989 PKZM0-32 278489 PKZM4-16 222350 PKZM4-25 222352 PKZM4-32 222353 PKZM4-40 222354 PKZM4-50 222355 PKZM4-58 222394 PKZM4-63 222413 PKZM4-16-CB 132591 PKZM4-25-CB 132592 PKZM4-32-CB 132593 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker 1.3 1 Spring-loaded terminals Part no. Article no. PKZM0-0,16-C 229669 PKZM0-0,25-C 229670 PKZM0-0,4-C 229671 PKZM0-0,63-C 229672 PKZM0-1-C 229673 PKZM0-1,6-C 229674 PKZM0-2.5-C 229675 Price See price list Std. pack Notes Information relevant for export to North America 1 off 1) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Suitable for 6 5 See also 3 UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified Branch circuit: Manual type E if used with terminal, or suitable for group installations Page 34 3 PKZM0-4-C 229676 PKZM0-6,3-C 229677 PKZM0-10-C 229678 PKZM0-12-C 278488 PKZM0-16-C 229679 Accessories 3 Standard auxiliary contacts 5 Trip-indicating auxiliary contact 6 Shunt release, undervoltage release Page 10 12 29 Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. Can be snap-fit to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height PTB 02 ATEX 3151, see manual 21 1 off Accessories Page 3 Standard auxiliary contacts 10 5 Trip-indicating auxiliary contact 12 6 Shunt release, undervoltage release 29 Only motor-protective circuit-breaker: Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height PTB 02 ATEX 3153, 21 see manual 6 5 3 3 1 off Not usable as a main switch 2) Product Standards Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. Switching capacity of SCCR 65 kA (480 Y/277 V) 22 kA (600 Y/347 V) NA Certification UL 489; CSA-C22.2 No.5-09; IEC 60947-4-1; CE marking Request filed for UL and CSA Specially designed for NA Yes Feeder and branch circuit as BCPD Suitable for AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 5 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker for starter combinations and transformers PKZM0 1 Screw terminals Max. motor rating Rated uninterrupted current AC-3 Motor-protective circuit-breakers for starter combinations Short-circuit protective breakers without overload function L I> T Transformer-protective circuitbreakers L I> Setting range 660 V 690 V Iu P P P A A kW kW kW – – – 0.06 0.16 2.2 PKM0-0,16 072720 1 off – 0.06 0.06 0.06 0.12 0.25 3.5 1 off 0.06 0.09 0.12 0.12 0.18 0.4 5.6 0.09 0.12 0.18 0.25 0.25 0.63 8.8 0.12 0.25 0.25 0.38 0.55 1 14 0.25 0.37 0.55 0.75 1.1 1.6 22 0.37 0.75 1.1 1.1 1.5 2.5 35 0.75 1.5 1.5 2.2 3 4 56 PKM0-0,25 072721 PKM0-0,4 072722 PKM0-0,63 072723 PKM0-1 072724 PKM0-1,6 072725 PKM0-2.5 072726 PKM0-4 072727 1.1 2.2 3 3 4 6.3 88 1 off 2.2 4 4 4 7.5 10 140 3 5.5 5.5 5.5 11 12 168 4 7.5 9 9 12.5 16 224 5.5 9 11 12.5 15 20 280 5.5 12.5 12.5 15 22 25 350 7.5 15 15 22 30 32 448 – – – – – 0.16 0.1…0.16 2.4 – – – – – 0.25 0.16…0.25 4.25 – – – – – 0.4 0.25…0.4 6.8 – – – – – 0.63 0.4…0.63 12 – – – – – 1 0.63…1 20 – – – – – 1.6 1…1.6 32 – – – – – 2.5 1.6…2.5 50 – – – – – 4 2.5…4 84 – – – – – 6.3 4…6.3 141 – – – – – 10 6.3…10 224 – – – – – 12 8…12 224 – – – – – 16 10…16 280 PKM0-6,3 072728 PKM0-10 072729 PKM0-12 278490 PKM0-16 044502 PKM0-20 203594 PKM0-25 044503 PKM0-32 278491 PKZM0-0,16-T 088907 PKZM0-0,25-T 088908 PKZM0-0,4-T 088909 PKZM0-0,63-T 088910 PKZM0-1-T 088911 PKZM0-1,6-T 088912 PKZM0-2.5-T 088913 PKZM0-4-T 088914 PKZM0-6,3-T 088915 PKZM0-10-T 088916 PKZM0-12-T 278492 PKZM0-16-T 088917 – – – – – 20 16…20 350 1 off – – – – – 25 20…25 437 PKZM0-20-T 088918 PKZM0-25-T 278493 kW kW – 440 V T 6 Std. pack 500 V 380 V 400 V 415 V P A Price See price list O v e r lo a d releases Ir 220 V 230 V 240 V P Short-circuit releases I rm Part no. Article no. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker for starter combinations and transformers 1.3 1 Notes When using the PKM0 as short-circuit protection for motors with heavy starting duty, a device must be selected whose rated operational current I e is higher by the following factors: CLASS 5 = 1.0 CLASS 10 = 1.0 CLASS 15 = 1.22 CLASS 20 = 1.41 CLASS 25 = 1.58 CLASS 30 = 1.73 CLASS 35 = 1.89 CLASS 40 = 2.0 6 5 3 3 Accessories 3 Standard auxiliary contacts 5 Trip-indicating auxiliary contact 6 Shunt release, undervoltage release Additional accessories Page 10 12 29 46 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height Assignment of the short-circuit protective breakers and contactors in “Fuseless motor-starter combinations” section. An appropriate overload relay must be fitted to protect motors against overload. 6 5 3 3 Accessories 3 Standard auxiliary contacts 5 Trip-indicating auxiliary contact 6 Shunt release, undervoltage release Page 10 12 29 For the protection of transformers with a high inrush current Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 7 1.3 PKE 1 Motor rating Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker Motor full-load current Basic device AC-3 220 V 230 V 240 V 380 V 400 V 415 V 440 V 500 V 660 V 690 V P I I I I I kW A A A A A Motor-protective circuit-breakers, type“1” and type “2” coordination 0.06 0.37 – – 0.09 0.54 0.31 – 0.12 0.72 0.41 0.37 0.18 1.04 0.6 0.54 0.25 – 0.8 0.76 0.37 – 1.1 1.02 0.55 – – – – – 0.33 0.48 0.7 0.9 – – – – 0.35 0.5 0.7 0.9 0.75 0.18 0.25 0.37 0.55 0.75 1.1 1.5 – 1.04 1.4 2 2.7 3.2 – – – – – 1.1 1.5 1.9 2.6 3.6 – – – 1.02 1.39 1.68 2.41 3.28 – – – – 1.2 1.5 2.1 2.9 1.1 – – – – 1.1 1.5 2.1 2.2 3 0.75 1.1 1.5 2.2 3 4 5.5 7.5 2.2 3 4 5.5 7.5 – – 3.2 4.6 6.3 8.7 11.5 – – – 8.7 11.5 14.8 19.6 26.4 – – – – 3.6 5 6.6 8.5 11.3 – – – 8.5 11.3 15.2 – – – – 3.3 4.6 6 7.7 10.2 – – – – 10.2 13.8 4 – – – – 4 5.3 6.8 9 – – – – 9 12.1 2.9 3.8 – – – – 3.8 4.9 6.5 8.8 – – – – 8.8 11 15 18.5 22 30 5.5 7.5 11 15 18.5 22 30 37 45 55 2.2 3 4 5.5 7.5 11 15 18.5 22 30 – – – – – 19.6 26.4 38 51 63 – – – – – 8.7 11.5 14.8 19.6 26.4 – – – – – 21.7 29.3 – – – – – 21.7 29.3 36 41 55 – – – – – 8.5 11.3 15.2 21.7 29.3 – – – 19.8 26.6 – – – – – 19.7 26.6 32.9 37.4 50.3 61.4 – – – – – 10.2 13.8 19.8 26.6 – – – 17.4 23.4 28.9 – – – – 17.4 23.4 28.9 33 44 54 65 – – – – 9 12.1 17.4 23.4 28.9 – – 12.6 17 20.9 23.8 32 – – – 17 20.9 23.8 32 39 47 58 – – – – 8.8 12.6 17 20.9 23.8 32 Notes 8 Setting range Overload releases Part no. Article no. 0.3…1.2 A PKE12 121721 1off 1…4 A PKE12 121721 1off 3…12 A PKE12 121721 1off 8…32 A PKE32 121722 1off 16…65 A PKE65 138258 1off Std. pack Start of delivery 07/2010 8…32 A Select switchgear and cables according to Class as shown in the table on Chapter 1.2 (Page 22) 1) For communications, module PKE-SWD-32 for contactors is required in addition, See catalog AUTOMATION AND CONTROL www.eaton.com/seasia-electrical See price list PKE65 138258 Start of delivery 07/2010 1off Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker Trip module Expanded 1) Trip module Standard usable for Part no. Article no. PKE12 PKE-XTU-1,2 121723 See price list Std. pack 1off usable for PKE12 Start of delivery 07/2010 PKE12 PKE-XTU-4 121724 Part no. Article no. See price list PKE-XTUA-1,2 121727 Std. pack 1off Start of delivery 07/2010 1off PKE12 Motor-protective circuitbreakers Standard Complete device Part no. See price Article no. list PKE12/XTU-1,2 121731 1.3 1 Std. pack 1off Start of delivery 07/2010 PKE-XTUA-4 121728 1off PKE12/XTU-4 121732 1off 1off PKE12/XTU-12 121733 1off 1off PKE32/XTU-32 121734 1off 1off PKE65/XTU-65 138516 1off Start of delivery 05/2010 PKE12 PKE32 PKE-XTU-12 121725 1off PKE12 PKE32 PKE-XTUA-12 121729 Start of delivery 05/2010 PKE32 PKE-XTU-32 121726 1off PKE32 PKE-XTUA-32 121730 Start of delivery 05/2010 PKE65 PKE-XTU-65 138259 1off PKE65 Start of delivery 10/2010 PKE65 PKE-XTUW-32 138261 Start of delivery 10/2010 Information relevant for export to North America PKE-XTUA-65 138260 Start of delivery 10/2010 1off PKE65 Start of delivery 10/2010 PKE-XTUWA-32 138262 Start of delivery 10/2010 Product Standards NA Certification 1off PKE65/XTUW-32 138517 1 off Start of delivery 10/2010 UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking Request filed for UL and CSA AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 9 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Standard auxiliary contacts NHI...-PKZ0... Standard auxiliary contacts 1 For motor-protective circuit-breakers Contact configuration Contact sequence N/O = normally open contact NC = normally closed contact 1 N/O 1 NC Circuit diagrams Connection method 1.13 1.21 Price Std. pack Screw terminals PKZM01 PKZM0 PKZM4 PKZM0-T PKM0 PKE 1) NHI11-PKZ0 072896 5 off Springloaded terminals PKZM01 PKZM0 PKZM4 PKZM0-T PKM0 PKE 1) NHI11-PKZ0-C 229680 5 off Screw terminals PKZM01 PKZM0 PKZM4 PKZM0-T PKM0 PKE 1) NHI12-PKZ0 072895 5 off Screw terminals PKZM01 PKZM0 PKZM4 PKZM0-T PKM0 PKE 1) NHI21-PKZ0 072894 5 off Screw terminals PKZM01 PKZM0 PKZM4 PKZM0-T PKM0 PKE 1) NHI-E-11-PKZ0 082882 5 off Screw terminals PKZM01 PKZM0 PKZM4 PKZM0-T PKM0 PKE 1) NHI-E-10-PKZ0 082884 5 off Springloaded terminals PKZM01 PKZM0 PKZM4 PKZM0-T PKM0 PKE 1) NHI-E-10-PKZ0-C 229681 5 off Springloaded terminals PKZM01 PKZM0 PKZM4 PKZM0-T PKM0 PKE 1) NHI-E-01-PKZ0-C 229682 5 off Screw terminals PKZM01 PKZM0 PKZM4 PKZM0-T PKM0 PKE 1) NHI-B-11-PKZ0 208277 5 off NHI11 I > 1 NC 1.14 1.22 1.13 1.21 1.14 1.22 L1L2L3 NHI11 I > 1 N/O Part no. Article no. See price list L1L2L3 1 N/O For use with 2 NC 1.13 1.21 1.31 L1L2L3 NHI12 I> 1.14 1.22 1.32 2 N/O 1 NC 1.13 1.21 1.33 L1L2L3 NHI21 I > 1.14 1.22 1.34 1 N/O 1 NC 1.53 1.61 L1L2L3 NHI-E-11 I > 1.54 1.62 1 N/O – 1.53 L1L2L3 NHI-E-10 I > 1.54 1 N/O – 1.53 L1L2L3 NHI-E-10 I > 1.54 – 1 NC 1.51 L1L2L3 NHI-E-01 I> 1.52 1 N/O 1 NC 1.13 1.21 1.14 1.22 L1L2L3 NHI-B-11 I > Notes 10 1) Only standard auxiliary contacts manufactured on or after CW 36/2009 are for use with PKE. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Standard auxiliary contacts 1.3 1 Notes Can be fitted to the right side of: motor-protective circuit-breakers, transformer protective circuit breakers and motor-protective circuit-breakers for starter combinations Notes Information relevant for export to North America Product Standards 1 5 UL File No. UL CCN CSA File No. CSA Class No. NA Certification Can be combined with: Trip-indicating auxiliary contact AGM, NHI-E-… 1 Can be fitted to motor-protective circuit-breakers, transformer-protective circuit-breakers and motor-protective circuit-breakers for starter combinations from serial number 01. 45 mm (PKZM0 and PKZM01) or 55 mm (PKZM4) widths of the motor-protective circuit-breakers remain unchanged. NHI-E...-PKZ0-C not for use with MSC...-type motor starter combinations. Accessories 1 Motor-protective circuit-breakers 5 Trip-indicating auxiliary contact Additional accessories UL 508; CSA-C22.2No.14; IEC 60947-4-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified 5 4 12 20 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 11 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Auxiliary contacts, undervoltage releases AGM2...., VHI... 1 Contact configuration N/O = normally open contact Contact sequence Circuit diagrams For use with NC = normally closed contact Part no. Article no. Price Std. pack See price list Trip indicators For motor-protective circuit-breakers 2 x 1 N/O Einschalten/Ausschalten "+" 4.43 " I >" 4.13 4.44 4.14 "+" 4.31 " I >" 4.21 4.32 4.22 L1L2L3 "+" "I >" Auslösen "+" I> L1L2L3 PKZM0 PKZM4 PKZM0-T PKM0 PKZM01 PKE 1) AGM2-10-PKZ0 072898 2 off PKZM0 PKZM4 PKZM0-T PKM0 PKZM01 PKE 1) AGM2-01-PKZ0 072899 2 off PKZM0 PKZM0-T PKM0 PKZM4 VHI20-PKZ0 203595 2 off PKZM01 VHI20-PKZ01 278495 5 off PKZM0 PKZM4 PKZM0-T PKM0 PKZM01 PKE 2) A-PKZ0(230V50Hz) 073187 2 off PKZM0 PKZM4 PKZM0-T PKM0 PKZM01 PKE 2) A-PKZ0(24VDC) 073200 2 off PKZM0 PKZM4 PKZM0-T PKM0 PKZM01 PKE 2) U-PKZ0(230V50Hz) 073135 2 off CL-PKZ0 082881 1 off "+" "I >" – 2 x 1 NC Einschalten/Ausschalten L1L2L3 "+" "I >" Auslösen "+" I> L1L2L3 "+" "I >" Early-make auxiliary contacts For motor-protective circuit-breakers 2 N/O – – 2 N/O – – 3.13 3.23 I > 3.14 3.24 Shunt release (for power circuit-breakers) – – – – – – C1 C2 Undervoltage release – – – D1 U< D2 – Current limiters For increasing switching capacity of motor-protective circuit-breakers without auto-protection – – – PKZM0 L PKZM4 PKE I >> T Notes 12 1) Only AGM2-...-PKZ0 manufactured on or after 06/2009 can be fitted. 2) Only A(U)-PKZ0... with serial number 02 or higher can be fitted. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Auxiliary contacts, undervoltage releases 1.3 1 Notes Notes Information relevant for export to North America Can be fitted to the right side of motor-protective circuit-breakers 1 Product Standards 3 UL File No. UL CCN CSA File No. CSA Class No. NA Certification Can be combined with: Standard auxiliary contacts NHI11-PKZ0 NHI12-PKZ0 NHI21-PKZ0 NHI-E-… UL 508; CSA-C22.2No.14; IEC60947-4-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified Separate indication of: a) General trip indication (overload) b) Short-circuit trip Local short-circuit indication by red indicator, manually resettable. Can be fitted to front of motor-protective circuitbreaker, 45 mm width of the motor-protective circuit-breaker remains unchanged. For early energization of undervoltage release, e.g. in emergency switching off circuits to EN 60204. VHI20-PKZ0 cannot be used in combination with PKZ0-X(R). 1 3 Accessories 1 Motor-protective circuit-breakers 3 Standard auxiliary contacts Page 4 10 Can be fitted to the left side of motor-protective circuit-breakers. Cannot be combined with: undervoltage release U-PKZ0 DC: Intermittent operation 5 s 1 1 Can be fitted to the left side of motor-protective circuit-breakers. Cannot be combined with: A-PKZ0 shunt release When combined with circuit-breaker, can be used as emergency switching off device to IEC/EN 60204. Accessories 1 Motor-protective circuit-breakers Further actuating voltages Page 4 29 Max. rated operating voltage U e = 690 V, rated uninterrupted current Iu = 63 A Can be used for individual and group protection. For group protection and in combination with PKZM4, order additional BK25/3 incoming terminal if required. Mounting next to or behind the motor-protective circuit-breaker. PKZM4: 16 - 63 A: 100 kA/400 V PKZM4: 16 - 63 A: 10 kA/690 V AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 13 1.3 1 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories for motor-protective circuit-breakers in enclosures Engineering PKZM01, PKZM Enclosure Part no. Part no. Surface mounting enclosure Motor-protective circuit-breaker PKZM01 CI-PKZ01 CI-PKZ01-G Accessories Degree of Handle protection color NHI..PKZ0 AGM2-..PKZ0 IP40 – – VHI..PKZ01 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – Redyellow – – IP65 IP65 – – – – – – IP41 – CI-PKZ01-PVT CI-PKZ01-PVS IP65 CI-PKZ01-SVB CI-PKZ01-SVB-V Motor-protective circuit-breaker PKZM0 CI-K2-PKZ0 VHI..-PKZ0 – – – – – – – – – – IP65 – – – – NHI-E..PKZ0 – – – – – CI-K2-PKZ0-G IP65 Black – CI-K2-PKZ0-GR CI-PKZ0-M IP65 IP40 Redyellow – – – – CI-PKZ0-GM IP55 Black – CI-PKZ0-GRM Motor-protective circuit-breaker PKZM0 + early-make auxiliary contact VHI-PKZ0 CI-K2-PKZ0-GV IP55 IP65 Redyellow – Black – – CI-K2-PKZ0-GRV CI-K2-PKZ0-GVM IP65 IP55 Redyellow – – Black – CI-K2-PKZ0-GRVM IP55 Notes 14 Redyellow – – – – – – – – – – – – – – – – – – – – – 1) – – – – – – – – The combination possibilities of circuit-breakers in an enclosure with accessory modules are identified by a 1) Always required AUTOMATION AND CONTROL www.eaton.com/seasia-electrical U-PKZ0 or A-PKZ0 – – – – – L-PKZ0 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE 1.3 PKZM4, PKZM01, PKZM0 1 Enclosure Part no. Part no. Accessories Degree of Handle protection color NHI..PKZ0 AGM2-..PKZ0 NHI-E..PKZ0 VHI..-PKZ0 VHI..PKZ01 – – – – – U-PKZ0 or A-PKZ0 L-PKZ0 Surface mounting enclosure Motor-protective circuit-breaker PKZM4 CI-K4-PKZ4-G IP65 Black – CI-K4-PKZ4-GR Installation enclosure Motor-protective circuit-breaker PKZM01 E-PKZ01 E-PKZ01-G E-PKZ01-PVT E-PKZ01-PVS IP65 IP40 IP65 IP65 E-PKZ01-SVB IP65 E-PKZ01-SVB-V IP65 Motor-protective circuit-breaker PKZM0 E-PKZ0 E-PKZ0-G IP40 IP55 Redyellow – – – – – – – – – – – – – – – Redyellow – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – Black – – – – – – – – – – – – 1) – – – – – – E-PKZ1-GR IP55 Red– – – yellow – – – – The combination possibilities of circuit-breakers in an enclosure with accessory modules are identified by a 1) Always required – – – Notes – AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 15 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Insulated enclosure PKZM01, PKZM0, PKZM4 Degree of protection 1 For use with Part no. Article no. Price See price list Std. pack Notes CI-PKZ01 281403 1 off Integrated terminal for PE(N) connection, two M25 cable entry knockouts at top and at bottom. CI-PKZ01-G 281404 1 off CI-PKZ01-SVB 281405 CI-PKZ01-SVB-V 281944 1 off IP65 CI-PKZ01-PVT 281406 1 off IP65 CI-PKZ01-PVS 281407 1 off PKZM01 CI-PKZ01-X 289934 1 off PKZM0-… +NHI or AGM +U or A +NHI-E +L-PKZ0 (2 off) CI-K2-PKZ0 219653 1 off CI-K2-PKZ0-G 219654 CI-K2-PKZ0-GR 219655 1 off Insulated enclosures for surface mounting For Motor-protective circuit-breaker PKZM01 – IP40 PKZM01 +NHI-E or VHI-PKZ01 +U or A or NHI +L (2 off) With operating membrane IP65 Lockable in Off position IP65 Lockable in Off position in combination with VHI-PKZ01 With emergency switching off mushroom button, maintained With emergency switching off mushroom button, with key-release IP65 For extension with inserts CI/E-PKZ01-X... unit As insert PKZM01 +NHI-E or +U or A +L (2 off) 1 off For Motor-protective circuit-breakers PKZM0 Cover with aperture dimensioned to accommodate front of breaker. IP40, when mounted turned through 90° to left/right With black-grey rotary knob With red-yellow rotary knob, for use as emergency switching off device to EN 60204 Cover with aperture dimensioned to accommodate front of breaker IP41 with vertical mounting IP40 PKZM0-… +NHI or U or A +L-PKZ0 (2 off) CI-PKZ0-M 267083 1 off With black-grey rotary knob With red-yellow rotary knob, for use as emergency switching off device to EN 60204 IP55 PKZM0-… +NHI-E +NHI or U or A +L-PKZ0 (2 off) CI-PKZ0-GM 260089 CI-PKZ0-GRM 260104 1 off IP65 IP65 IP55 M25 metric cable entry knockout, top and bottom Cable push-through membrane top, bottom, in the back plate and as a control line entry. Insulated enclosure CI-K2 incl. N and PE terminal. 1 off Integrated terminal for PE(N) connection, two M25 cable entry knockouts at top and at bottom. 1 off For Motor-protective circuit-breakers PKZM0 with early-make VHI auxiliary contacts With black-grey rotary knob With red-yellow rotary knob, for use as emergency switching off device to EN 60204 With black-grey rotary knob With red-yellow rotary knob, for use as emergency switching off device to EN 60204 IP65 IP65 IP55 IP55 PKZM0-... and VHI +NHI or AGM +U or A +L (2 off) CI-K2-PKZ0-GV 219657 CI-K2-PKZ0-GRV 219656 1 off PKZM0-... and VHI +U or A (undervoltage or shunt release) +L-PKZ0 (2 off) CI-PKZ0-GVM 263526 CI-PKZ0-GRVM 263525 1 off PKZM4-… +VHI or NHI-E +NHI and AGM +U or A +L-PKZ0 (2 off) CI-K4-PKZ4-G 225524 CI-K4-PKZ4-GR 225525 1 off 1 off 1 off M25 metric cable entry knockout, top and bottom Cable push-through membrane top, bottom, in the back plate and as a control line entry. Insulated enclosure CI-K2 incl. N and PE terminal. Integrated terminal for PE(N) connection, two M25 cable entry knockouts at top and at bottom. For Motor-protective circuit-breakers PKZM4 16 With black-grey rotary knob IP65 With red-yellow rotary knob, for use as emergency switching off device to EN 60204 IP65 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1 off Metric knockout: Top and bottom: M25/M32 In the back plate: M25/M32 Control cable entry: M20 CI-K4 insulated enclosure including insulated PE terminal Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Insulated enclosure 1.3 E-PKZ Degree of protection For use with Part no. Article no. Price See price list Std. pack Information relevant for export to North America 1 off Product Standards E-PKZ01-G 281634 1 off UL File No. UL CCN CSA File No. CSA Class No. NA Certification 1 Insulated enclosures for flush mounting For Motor-protective circuit-breaker PKZM01 Integrated terminal for PE(N) connection. Front IP40 PKZM01 +NHI or U or A +NHI-E or VHI +L (2 off) With operating Front IP65 membrane E-PKZ01 281633 Lockable in Off position Front IP65 PKZM01 +U or A +NHI-E E-PKZ01-SVB 281635 1 off Lockable in Off position, in combination with VHI-PKZ01 Front IP65 PKZM01 +U or A +NHI-E or VHI E-PKZ01-SVB-V 281943 1 off With emergency switching off mushroom button, maintained Front IP65 E-PKZ01-PVT 281636 1 off With emergency switching off mushroom button, with key-release Front IP65 E-PKZ01-PVS 281637 1 off For extension with inserts CI/E-PKZ01X... unit As insert E-PKZ01-X 289935 1 off For Motor-protective circuit-breakers PKZM0 Integrated terminal for PE(N) connection. Cover with aperture Front IP40 PKZM0-… dimensioned to +NHI or U or accommodate front A +L-PKZ0 of breaker (2 parts) E-PKZ0 072906 1 off With black-grey rotary knob E-PKZ0-G 072907 With red-yellow rotary knob, for use as emergency switching off device to EN 60204 Front IP55 Front IP55 PKZM01 PKZM0-… +NHI or U or A +NHI-E +L-PKZ0 (2 parts) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification E-PKZ0-GR 072908 1 off Product Standards 1 off UL File No. UL CCN CSA File No. CSA Class No. NA Certification Degree of Protection AUTOMATION AND CONTROL www.eaton.com/seasia-electrical UL 508; CSA-C22.2 No.14; IEC609474-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified UL 508; CSA-C22.2 No.14; IEC609474-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified UL 508; CSA-C22.2 No.14; IEC609474-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified IEC: Front IP55, UL/CSA Type: 1,12, 3R 17 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Insulated enclosure CI-PKZ 1 Degree of protection For use with Part no. Article no. Price Std. pack Information relevant for export to North America Product Standards See price list Insulated enclosures for surface mounting For Motor-protective circuit-breaker PKZM01s Integrated terminal for PE(N) connection. IP41 PKZM01 +NHI-E or VHI-PKZ01 +U or A or NHI +L (2 off) CI-PKZ01-NA 281408 1 off With operating membrane IP65 PKZM01 +NHI-E or VHI-PKZ01 +U or A or NHI +L (2 off) CI-PKZ01-NA-G 281409 1 off Lockable in Off position IP65 PKZM01 +NHI-E or VHI-PKZ01 +U or A +L (2 off) CI-PKZ01-NA-SVB 281630 1 off Lockable in Off position, in combination with VHI-PKZ01 IP65 PKZM01 +NHI-E +U or A +L (2 off) CI-PKZ01-NA-SVB-V 281945 1 off With emergency switching off mushroom button, maintained IP65 CI-PKZ01-NA-PVT 281631 1 off With emergency switching off mushroom button, with key-release IP65 CI-PKZ01-NA-PVS 281632 1 off For Motor-protective circuit-breakers PKZM0 Integrated N and PE terminals; lower section without knockouts With black-grey IP55 PKZM0-… CI-K2-PKZ0-NA-G rotary knob +NHI or U or 262680 A +NHI-E +L-PKZ0 (2 parts) With red-yellow IP55 CI-K2-PKZ0-NA-GR 1 off 1 off rotary knob, for use 262681 as emergency switching off device to EN 60204 For Motor-protective circuit-breakers PKZM0 with early-make auxiliary contacts Integrated N and PE terminals; lower section without knockouts 18 With black-grey rotary knob IP55 With red-yellow rotary knob, for use as emergency switching off device to EN 60204 IP55 PKZM0-… +VHI… + U… +L-PKZ0 (2 parts) CI-K2-PKZ0-NA-GV 262682 1 off CI-K2-PKZ0-NA-GRV 262683 1 off AUTOMATION AND CONTROL www.eaton.com/seasia-electrical UL 508; CSA-C22.2 No.14; IEC609474-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Specially designed for NA Degree of Protection IEC: IP41, UL/CSA Type: - Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Insulated enclosure 1.3 SVB-PKZ, CL/EPKZ01 Degree of protection 1 For use with Part no. Article no. Price See price list Std. pack Information relevant for export to North America 3 off Product Standards Insulated enclosures, accessories Padlocking feature For up to 3 padlocks with 3 – 6 mm hasp thickness, for use as main switch to IEC/EN60204 Lockable in the – CI-K2-PKZ0-G(R)(V) SVB-PKZ0-CI 0-position of the PKZM0 035129 CI-PKZ0-G(R)(V)M or Motor-protective circuit-breaker PKZM4. – – E-PKZ0-G(R) SVB-PKZ0-E 035127 – – 3 off CI-K4-PKZ4-G(R) SVB-PKZ4-CI 225526 1 off UL File No. UL CCN CSA File No. CSA Class No. NA Certification UL 508; CSA-C22.2 No.14; IEC609474-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified Neutral terminal For connection of a 5th conductor Flexible, 1 - 4 mm² – CI-K2-PKZ0-... K-CI-K1/2 207451 20 off 63 A, flexible, 6 - 16 mm² – CI-K4-PKZ4-G(R) K25/1 096200 10 off – – E-PKZ0(-G)(-GR) E-PKZ01(-G) N-PKZ0 082160 20 off CI/E-PKZ01XG 289936 1 off PKZM01 +NHI-E +U or A +L (2 off) PKZM01 +NHI-E or VHI-PKZ01 +U or A +L (2 off) PKZM01 +NHI-E or VHI-PKZ01 +U or A +L (2 off) CI/E-PKZ01XSVB 289939 1 off CI/E-PKZ01XPVT 289937 1 off CI/E-PKZ01XPVS 289938 1 off PKZM01 VHI-PKZ01 +U or A +L (2 off) CI/E-PKZ01XSVB-V 289980 1 off Units for insulated enclosures for PKZ01 Combinable with CI-PKZ01-X and E-PKZ01-X. PKZM01 With operating membrane Front IP65 +NHI-E or VHI-PKZ01 +U or A or NHI +L (2 off) Lockable in Off position Front IP65 With emergency switching off mushroom button, maintained Front IP65 With emergency switching off mushroom button, with key-release Front IP65 Lockable in Off position, in combination with VHI-PKZ01 Front IP65 UL/CSA certification not required AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 19 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories Accessories 1 Cable entry Metric cable glands to EN 50262 • With lock nut and built-in strain relief • IP68 up to 5 bar, halogen free Metric diaphragm grommets • IP66 • With integral push-through diaphragm Door coupling handles Degree of protection IP65, UL/CS Type 4X / Type12 Clamp cover Pluggable extension shaft – External cable diameter mm M20 20.5 6 - 13 V-M20 206910 20 off M25 25.5 9 - 17 V-M25 206911 20 off M32 32.5 13 - 21 V-M32 206912 10 off M32 32.5 18 - 25 V-M32G 226156 10 off M20 20.5 1 - 13 100 off M25 25.5 1 - 18 KT-M20 207602 KT-M25 207603 M32 32.5 1 - 25 KT-M32 207604 100 off For use with Part no. Article no. Price See price list Part no. Article no. Price See price list Std. pack 100 off Std. pack Notes Pluggable PKZ0-XAH extension shaft, can be cut to any required length for installation depths of 100…240 mm. Follower included in delivery. With ON/OFF switch position and “+” (tripped), lockable With 3 padlocks, 4 – 8 mm hasp. Cannot be used in combination with VHI20-PKZ0. For use as main switch to IEC/EN 60204 Black PKZM0 PKZM4 PKZ0-XH1) 106132 1 off For use as a main switch with emergency switching off function to EN 60204 Redyellow PKZM0 PKZM4 PKZ0-XRH1) 106133 1 off For use as a main switch to EN 60204 in MCC power distribution systems and with PKZM0 installed rotated by 90° Black PKZM0 PKZM4 PKZ0-XH-MCC1) 106136 1 off For use as a main switch with emergency switching off function to EN 60204 in MCC power distribution systems and with PKZM0 installed rotated by 90° For use as main switch to IEC/EN 60204 Redyellow PKZM0 PKZM4 PKZ0-XRH-MCC1) 106137 1 off Black PKE PKE-XH1) 142416 1 off For use as a main switch with emergency switching off function to EN 60204 Redyellow PKE PKE-XRH1) 142417 1 off For use as a main switch to EN 60204 in MCC power distribution systems and with PKE installed rotated by 90° Black PKE PKE-XH-MCC1) 142418 1 off For use as a main switch with emergencyswitching off function to EN 60204 in MCC power distribution systems and with PKE installed rotated by 90° For increasing the degree of protection of the PKZM4 to IP2X Redyellow PKE PKE-XRH-MCC1) 142419 1 off – PKZM4 HB-PKZ42) 256581 1 off Suitable for connecting cables with a max. external diameter of 9.5 mm – PKZM0 PKZM4 PKZ0-XAH1) 106134 1 off Follower not included – Pluggable PKZ0-XAH extension shaft, can be cut to any required length for installation depths of 100…240 mm. Follower included in delivery. With ON/OFF switch position and “+” (tripped), lockable With 3 padlocks, 4 – 8 mm hasp. Information relevant for export to North America 1) 20 Drilling dimensions mm Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Degree of Protection UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified IEC: IP65, UL/CSA Type: 4X, 12 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 2) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories 1.3 Accessories 1 Notes Part no. Article no. Stepless adjustment via scale from 75 – 115 mm. M22-TA 226161 Price See price list Std. pack Information relevant for export to North America 1 off Product Standards Telescopic adapters With 45 mm top-hat rail to IEC/EN 60715 for compensation of the mounting depth of rear-mounted devices enclosures CI-K and cabinets Telescopic clip Lockable rotary handle For locking motor-protective circuit-breakers PKZM0, PKZM4 and PKE as a main switch in compliance with EN 60204. Can be padlocked in the “0” position. Hasp thickness: 3 – 6.35 mm Can not be combined with VHI-PKZ0. Holding facility To prevent tampering with the overload release and the test function, it can be sealed using industry standard sealing wire For use with motor-protective circuit-breakers PKZM0 and PKZM4 – PL-PKZ0 203599 5 off Mounting angle bracket For screw fixing to mounting plate – PKE32-XMB 134837 20 off UL File No. UL CCN CSA File No. CSA Class No. NA Certification AK-PKZ0 030851 5 off Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Product Standards NA Certification Documentation Indicator lights with glow lamp Motor-protective circuitbreakers PKZM0, overload monitoring of EEx e motors German/English AWB1210-1458D/GB 266164 1 off Motor-protective circuitbreakers PKZM4, overload monitoring of EEx e motors German/English AWB1210-1457D/GB 266165 1 off Motor-protective circuitbreakers PKE, EEx electric motor overload monitoring German/English AWB1210-1631DE/EN 134836 1 off For use withColorVoltage Color Voltage Us Part no. Article no. V Price See price list IEC/EN60947-5; UL 508; CSA-C22.2 No.14-05; CSAC22.2 No.94-91; CE marking E29184 NKCR 012528 3211-03 UL Listed, CSA certified UL 508; CSA-C22.2 No.14; IEC/EN 609474-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified UL 508; CSA-C22.2 No.14; IEC/EN 609474-1; CE marking Request filed for UL and CSA Std. pack CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) White 110 - 230 L-PKZ0(230V) 082151 10 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) White 230 - 400 L-PKZ0(400V) 082152 10 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) White 415 - 500 L-PKZ0(500V) 082153 5 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) Green 110 - 230 L-PKZ0-GN(230V) 082154 10 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) Green 230 - 400 L-PKZ0-GN(400V) 082155 10 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) Green 415 - 500 L-PKZ0-GN(500V) 082156 5 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) Red 110 - 230 L-PKZ0-RT(230V) 082157 10 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) Red 230 - 400 L-PKZ0-RT(400V) 082158 10 off AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 21 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Busbar adapters Busbar adapters for PKZ and PKE Approved to UL508. For fitting to flat copper busbars with 60mm between busbar centers, suitable for 5 mm and 10 mm busbar thickness. 1 Rated operational voltage Ue Conductor crosssection V Adapter width Mounting rails mm Number For use with Part no. Article no. Price See price list Std. pack Notes Rated operational current 16 A For starters with springloaded terminals 690 AWG 14 (2.5 mm²) 45 2 PKZM0-C + DILMC7 PKZM0-C + DILMC9 PKZM0-C + DILMC12 BBA0C-16 101455 4 off According to UL 508: Ie = 12 A Rated operational current 25 A For reversing starters 690 AWG 12 (4 mm²) 90 1 PKZM0, PKE + 2 x DILM7-01 PKZM0, PKE + 2 x DILM9-01 PKZM0, PKE + 2 x DILM12-01 MSC-R-0,25-M7… MSC-R-12-M12… BBA0R-25 101453 2 off In combination with individual components PKZM0 and DILM, use reversing starter kit PKZM0-XRM12. Fully assembled and tested combination with MSC-R Chapter 1.4 (Page 18) Only busbar adapters/wiring sets manufactured on or after CW35/ 2009 can be used for PKE. Can be used universally 690 AWG 12 (4 mm²) 45 2 – BBA0-25/2TS 101481 4 off Mounting rails can be moved within 1.25 mm grid. For DOL starters 690 AWG 12 (4 mm²) 45 1 PKZM0, PKE + 2 x DILM17-01 PKZM0, PKE + 2 x DILM2501PKZM0, PKE + 2 x DILM25-01 PKZM0, PKE + 2 x DILM32-01 MSC-R-16-M17… MSC-R-32-M32… BBA0-25 101451 4 off In combination with individual components PKZM0 and DILM, use DOL starter kit PKZM0-XRM12. Fully assembled and tested combination with MSC-D Chapter 1.4 (Page 2) Only busbar adapters/wiring sets manufactured on or after CW35/ 2009 can be used for PKE. For soft starters 690 AWG 12 (4 mm²) 45 1 PKZM0, PKE + DS7...004N... PKZM0, PKE + DS7...007N... PKZM0, PKE + DS7...009N... PKZM0, PKE + DS7...012N... BBA0L-25 142526 1 off – Rated operational current 32 A For reversing starters 690 AWG 10 (6 mm²) 90 3 PKZM0, PKE + 2 x DILM17-01 PKZM0, PKE + 2 x DILM25-01 PKZM0, PKE + 2 x DILM32-01 MSC-R-16-M17… MSC-R-32-M32… BBA0R-32 101454 2 off In combination with single components PKZM0 and DILM, wiring kit PKZM0-XM32DE and reversing starter wiring kit DILM32-XRL can be used. Fully assembled and tested combination with MSC-R Chapter 1.4 (Page 18) Only busbaradapters/wiring sets manufactured on or after CW 35/ 2009 can be used for PKE. UL 508A; CSA-C22.2 No. 14; IEC60439-1; CE marking UL File No.E300273 NMTR, NMTRZ CSA File No. CSA Class No. NA Certification Max. Voltage Rating Information relevant for export to North America Product Standards UL File No. UL CCN 22 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 232140 3211-37 UL Listed, CSA certified 600 V AC Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Busbar adapters 1.3 1 Rated operational voltage Ue Conductor crosssection V Adapter width Mounting rails mm Number For use with Part no. Article no. Price See price list Std. pack Notes Rated operational current 32 A Can be used universally. 690 – 45 2 PKZM0…, PKE + DILM… BBA0-32/2TS-C 2) 116708 4 off Universal adapter 1-, 2- and 3phase applications. Mounting rail can be moved within 1.25 mm grid. For conductor cross-sections, round conductors of up to 6 mm 2. Only busbaradapters/wiring sets manufactured on or after CW 35/ 2009 can be used for PKE. For DOL starters. 690 AWG 10 (6 mm²) 45 2 PKZM0, PKE + DILM17 PKZM0, PKE + DILM25 PKZM0, PKE + DILM32 MSC-D-16-M17… MSC-D-32-M32… BBA0-32 1) 101452 4 off In combination with individual components PKZM0 and DILM wiring kit PKZM0-XM32DE can be used. Fully assembled and tested combination with MSC-D Chapter 1.4 (Page 2) Only busbar adapters/wiring sets manufactured on or after CW35/ 2009 can be used for PKE. For soft starters 690 AWG 10 (6 mm²) 45 2 PKZM0, PKE + DS7...016N... PKZM0, PKE + DS7...024N... PKZM0, PKE + DS7...032N... BBA0L-32 142527 1 off – For 160 mm adapter system with motorprotective circuitbreakers – 690 AWG 10 (6 mm²) 45 1 PKZM0, PKE BBA0K-32 142528 1 off – Rated operational current 63 A For DOL starters. 690 AWG 8 (10 mm²) 55 2 PKZM4 + DILM17 PKZM4 + DILM25 PKZM4 + DILM32 PKZM4 + DILM40 PKZM4 + DILM50 PKZM4 + DILM65 BBA4L-63 1) 101459 4 off The following can be used to establish an electrical connection: For PKZM4 + DILM17 to DILM32: MVS-LB0-0M-G For PKZM4 + DILM40 to DILM65: PKZM4-XM65DE. For motor-protective circuit-breakers 690 AWG 8 (10 mm²) 54 1 PKZM4 BBA4-63 1) 101457 4 off – Information relevant for export to North America 1) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Max. Voltage Rating 2) UL 508; CSA-C22.2 No.14; IEC60439-1; CE marking E300273 NMTR, NMTR7 232140 3211-37 UL Listed, CSA certified 600 V AC Product Standards UL File No. UL CCN NA Certification Max. Voltage Rating UL 508; CSA-C22.2 No.14; IEC60439-1; CE marking E300273 NMTR, NMTR7 UL Listed, CSA certified 600 V AC AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 23 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Busbar adapters BBA, PKZM0-XM Rated operational voltage Ue 1 Conductor crosssection V Adapter width Mounting rails For use with Part no. Article no. Price See price list Std. pack Notes mm Number – – 45 2 – BBA0/2TS-L1) 101482 4 off Mounting rails can be moved within a 1.25 mm grid. Can be used to mount reversing and star-delta starters. – – 54 2 – BBA4/2TS-L1) 101483 4 off Mounting rails can be moved within a 1.25 mm grid. Can be used to mount reversing and star-delta starters. Side-mounted module, can be attached on both sides. – – 9 – – BBA-XSM 1) 101484 10 off Can be grouped with busbar adapters in order to extend the mounting width. Busbar adapters accessories Mounting rails – – 45 – BBA… PKZM0-XMR 2) 239364 10 off – Busbar adapters accessories Mounting rails – – 54 – BBA… PKZM0-XMR54 2) 113911 10 off – Busbar adapters accessories Mounting rails – – 72 – BBA… PKZM0-XMR72 2) 113912 10 off – Connecting cable – – – – – BBA… BBA-XLT-6-130 3) 116902 30 off – – – – – BBA… BBA-XLT-16-142 3) 116903 30 off – Without electrical contacts Empty module. Information relevant for export to North America 1) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Max. Voltage Rating 2) UL 508A; CSA-C22.2 No.14; IEC60439-1; CE marking E300273 NMTR, NMTR7 232140 3211-37 UL Listed, CSA certified 600 V AC Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification 3) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification 24 UL 508A; CSA-C22.2 No.14; IEC60439-1; CE marking On request On request On request On request UL Recognized, CSA certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical UL 508A; CSA-C22.2 No.14; IEC60947-4-1; CE marking E300273 NMTR, NMTR7 232140 3211-37 UL Listed, CSA certified Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Wiring sets 1.3 Wiring set For use with Part no. Article no. DOL starter PKZM0, PKE + DILM7 PKZM0, PKE + DILM9 PKZM0, PKE + DILM12 PKZM0, PKE + DILM15 DS7-34…SX004… DS7-34…SX007… DS7-34…SX009… DS7-34…SX012… DOL starter Std. pack Notes PKZM0-XDM12 283149 1 off Consists of: • Mechanical connection element for PKZM0 and contactor • Main supply wiring between PKZM0 and contactor with tool-less plug connection • Cable routing As auxiliary contact, use DILA-XHIT... Chapter 1.1 (Page 38) Cannot be combined with NHI-E…PKZ0-C. U e ̰ 415 V 1) PKZM0, PKE + DILM17 PKZM0, PKE + DILM25 PKZM0, PKE + DILM32 PKZM0-XDM32 283153 1 off Consists of: • Top-hat rail adapter plates • Power supply wiring between PKZ and contactor 1) PKZM4 + DILM40 PKZM4 + DILM50 PKZM4 + DILM65 PKZM4-XDM65 101053 1 off Reversing starters PKZM0, PKE + DILM7-01 PKZM0, PKE + DILM9-01 PKZM0, PKE + DILM12-01 PKZM0-XRM12 283185 1 off Consists of: • Mechanical connection element for PKZM0 and contactor • Reversing starters main supply wiring with tool-less plug connection • Control cables for electrical interlocking in tool-less plug connection: – K1M: A1 -K2M: 21 – K1M: 21 -K2M: A1 – K1M: A2 -K2M: A2 • Cable routing As auxiliary contact DILA-XHIT...use Chapter 1.1 (Page 38) Can not be combined with AGM ϋ PKZ0. U e ̰ 415 V 1) Reversing starters PKZM0, PKE + DILM17 PKZM0, PKE + DILM25 PKZM0, PKE + DILM32 PKZM0-XRM32 283189 1 off Consists of: • Top-hat rail adapter plates • Reversing starters supply wiring1) Wiring kit PKZM0, PKE + DILM17 PKZM0, PKE + DILM25 PKZM0, PKE + DILM32 DS7-34…SX016… DS7-34…SX024… DS7-34…SX032… PKZM4 + DILM40 PKZM4 + DILM50 PKZM4 + DILM65 PKZM0-XM32DE 239349 5 off • Main supply wiring between PKZM0 and contactor • Use only in combination with busbar adapter or mounting rail adapter plate PKZM4-XM65DE 101056 5 off • Main current supply between PKZM4 and contactor Top-hat rail adapter plates PKZM0-XDM12 PKZM0-XRM12 PKZM0-XC45 283132 4 off Consists of: • 45 mm wide adapter plate • Connection element for side-by-side positioning of further plates 1) Top-hat rail adapter plates PKZM4 + DILM40 PKZM4 + DILM50 PKZM4 + DILM65 PKZM4-XC55/2 101054 4 off Consists of: • 55 mm wide adapter plate • Connection cam for additional plates 1) • For use with reversing and start-delta starters Soft starters PKZM0, PKE + DS7...004N... PKZM0, PKE + DS7...007N... PKZM0, PKE + DS7...009N... PKZM0, PKE + DS7...012N... PKZM0-XC45L 142529 1 off Consists of: • 45 mm wide adapter plate Soft starters PKZM0, PKE + DS7...016N... PKZM0, PKE + DS7...024N... PKZM0, PKE + DS7...032N... PKZM0-XC45L/2 142570 1 off Consists of: • 45 mm wide adapter plate Notes Price See price list 1) 1 Use only busbar adapters/wiring sets manufactured on or after CW35/2009 for PKE. Information relevant for export to North America 2) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification 3) UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified UL/CSA certification not required 4) Product Standards UL File No. UL CCN NA Certification Max. Voltage Rating UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking E300273 NMTR, NMTR7 UL Listed, CSA certified 600 V AC AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 25 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor feeder plugs, three-phase commoning links Motor feeder plug 1 Description For use with Part no. Article no. Price See price list PE module with contact plate DILM(C)7 DILM12-XMCE DILM(C)9 121764 DILM(C)12 DILM(C)15 Std. pack Notes Information relevant for export to North America 5 off 35 x 7.5 (15) mm mounting rail (as per DIN EN 60715) with PE function required. For connection of: PE 0.75 – 4 mm2 Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking NA Certification Request filed for UL and CSA 1 off 35 x 7.5 (15) mm mounting rail (as per DIN EN 60715) with PE function required. For connection of: L1, L2, L3, PE 0.75 – 2.5 mm 2 Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking NA Certification Request filed for UL and CSA 1 off For connection of: L1, L2, L3, PE 0.75 – 2.5 mm 2 Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking NA Certification Request filed for UL and CSA Motor feeder plug with PE module andcontact plate DILM(C)7 DILM(C)9 DILM(C)12 DILM(C)15 DILM12-XMCP/E 121769 Motor feeder plug with PE module without contact plate PKZM0/PKE + DILM(C)7 PKZM0/PKE + DILM(C)9 PKZM0/PKE + DILM(C)12 PKZM0/PKE + DILM(C)15 MSC-D(E)-…-M7… MSC-D(E)-…-M9… MSC-D(E)-…-M15… DILM12-XMCP/T 121770 Three-phase commoning links, incoming unit via terminals 1, 3, and 5 Finger- and back-of-hand-proof, short-circuit proof, U e=690 V, Iu=63 A Can be extended through rotated installation Circuit-breakers Length Unit width Part no. Article no. Number mm mm Price See price list For PKZM0-... or PKE without side-mounted auxiliary contacts or voltage releases 2 90 45 B3.0/2-PKZ01) 063961 Std. pack Notes 10 off For parallel feeding of multiple motor-protective circuit-breakers on terminals 1, 3, and 5 B3.0/3-PKZ01) 232289 4 180 45 B3.0/4-PKZ01) 063960 5 225 45 B3.0/5-PKZ01) 232290 For motor-protective circuit-breakers with one auxiliary contact or tripindicating auxiliary contact each fitted to right side 2 99 45 + 9 B3.1/2-PKZ01) 044945 10 off B3.1/3-PKZ01) 044946 4 207 45 + 9 B3.1/4-PKZ01) 044947 5 261 45 + 9 B3.1/5-PKZ01) 044948 For PKZM0-... or PKE with one auxiliary contact or trip-indicating auxiliary contact each fitted to right side, or one voltage release fitted on left side 10 off 3 3 135 153 45 45 + 9 2 108 45 + 18 4 234 45 + 18 B3.2/2-PKZ01) 063963 B3.2/4-PKZ01) 063959 10 off 10 off 10 off For parallel feeding of multiple motor-protective circuit-breakers on terminals 1, 3, and 5 10 off 10 off 10 off 10 off For parallel feeding of multiple motor-protective circuit-breakers on terminals 1, 3, and 5 Information relevant for export to North America 1) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification 26 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical UL 508A; CSA-C22.2 No.14; IEC60947-4-1; CE marking E36332 NLRV 98494 3211-06 UL Listed, CSA certified Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Incoming terminals 1.3 HB3...PKZO, BK...I3-PKZ Circuitbreakers For use with 1 Unit width Number Part no. Article no. Price See price list Std. pack Notes 20 off – mm Shroud for unused terminals Protection against direct contact. For covering unused terminals on three-phase commoning link B3...-PKZ0 – – – H-B3-PKZ01) 032721 Incoming terminals – PKZM0 PKE – BK25/3-PKZ02) 032720 5 off For three-phase commoning link, protected against accidental contact, U e = 690 V, Iu = 63 A For conductor cross-sections: 2.5 - 25 mm 2 stranded 2.5 - 16 mm 2 flexible with ferrule AWG 14 - 6, usable on terminals 1, 3, and 5 – PKZM0 – BK25/3-PKZ0-E3) 262518 5 off – PKZM4 – BK50/3-PKZ4-E4) 272165 1 off For three-phase commoning link, protected against accidental contact, U e = 690 V, Iu = 60 A For conductor cross-sections: 2.5 - 25 mm 2 stranded 2.5 - 16 mm 2 flexible with ferrule AWG 14 - 6 For assembly of Type E starters. Can be combined with three-phase commoning link B3…PKZ4. I u = 120 A. For assembly of Type E starters. Information relevant for export to North America 1) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification 2) UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking E36332 NLRV 98494 3211-06 UL Listed, CSA certified Product Standards UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking E36332 NLRV 98494 3211-06 UL Listed, CSA certified Product Standards 3) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Specially designed for NA Suitable for UL File No. UL CCN CSA File No. CSA Class No. NA Certification UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified 4) PKZM0/PKE, line terminal required for Type E/F applications UL File No. UL CCN CSA File No. CSA Class No. NA Certification Specially designed for NA Suitable for UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking E36332 NLRV 12528 3211-06 UL Listed, CSA certified PKZM4/PKE, line terminal required for Type E/F applications AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 27 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Three-phase commoning links Three-phase commoning links 1 Finger- and back-of-hand-proof, short-circuit proof Ue= 690 V, Iu= 128 A Circuit-breakers Length Unit width Number mm mm Part no. Article no. Price See price list Std. pack Information relevant for export to North America Product Standards UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking E36332 UL File No. NLRV UL CCN 12528 CSA File No. 3211-06 CSA Class No. UL Listed, CSA certified NA Certification For PKZM4 without side-mounted auxiliary contacts or voltage releases 2 110 55 B3.0/2-PKZ4 220220 1 off 3 165 55 B3.0/3-PKZ4 220221 1 off 4 220 55 B3.0/4-PKZ4 220222 1 off For PKZM4 with one auxiliary contact or trip-indicating auxiliary contact each fitted on the right side B3.1/2-PKZ4 1 off 2 119 55 + 9 220223 3 183 55 + 9 B3.1/3-PKZ4 220224 1 off 4 247 55 + 9 B3.1/4-PKZ4 220225 1 off For PKZM4 with one auxiliary contact or trip-indicating auxiliary contact each fitted to right side, or one voltage release fitted to left side 2 128 55 + 18 B3.2/2-PKZ4 220226 1 off 4 274 55 + 18 B3.2/4-PKZ4 220227 1 off Shroud for unused terminals Protection against direct contact. To cover unused terminals on three-phase commoning link 28 Circuit-breakers Length Unit width Number mm mm – – – Part no. Article no. H-B3-PKZ4 220228 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Price See price list Std. pack Information relevant for export to North America 10 off Product Standards UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking E36332 UL File No. NLRV UL CCN 12528 CSA File No. 3211-06 CSA Class No. UL Listed, CSA certified NA Certification Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Actuating voltages 1.3 A-PKZO, U-PKZO Actuating voltage 1 Part no. Article no. Price See price list Std. pack Part no. Article no. Price See price list Std. pack Notes Shunt release, undervoltage release AC Standard voltage 24 V 50 Hz A-PKZ0(24V50Hz) 1) 073181 2 off U-PKZ0(24V50Hz) 1) 073129 2 off 110 V 50 Hz A-PKZ0(110V50Hz) 1) 073184 2 off U-PKZ0(110V50Hz) 1) 073132 2 off 220 V 50 Hz A-PKZ0(220V50Hz) 1) 073186 2 off U-PKZ0(220V50Hz) 1) 073134 2 off 230 V 50 Hz A-PKZ0(230V50Hz) 1) 073187 2 off U-PKZ0(230V50Hz) 1) 073135 2 off 240 V 50 Hz A-PKZ0(240V50Hz) 1) 073188 2 off U-PKZ0(240V50Hz) 1) 073136 2 off 380 V 50 Hz A-PKZ0(380V50Hz) 1) 073189 2 off U-PKZ0(380V50Hz) 1) 073137 2 off 400 V 50 Hz A-PKZ0(400V50Hz) 1) 073190 2 off U-PKZ0(400V50Hz) 1) 073138 2 off 415 V 50 Hz A-PKZ0(415V50Hz) 1) 073191 2 off U-PKZ0(415V50Hz) 1) 073139 2 off 120 V 60 Hz A-PKZ0(120V60Hz) 1) 073195 2 off U-PKZ0(120V60Hz) 1) 073143 2 off 240 V 60 Hz A-PKZ0(240V60Hz) 1) 073198 A-PKZ0(440V60Hz) 1) 082164 2 off U-PKZ0(240V60Hz) 1) 073146 U-PKZ0(440V60Hz) 1) 082161 2 off A-PKZ0(480V60Hz) 1) 073199 2 off U-PKZ0(480V60Hz) 1) 073147 2 off …V 50 Hz (24 - 500 V) A-PKZ0(*V50Hz) 1) 982165 2 off U-PKZ0(*V50Hz) 982162 …V 60 Hz (24 – 600 V) A-PKZ0(*V60Hz) 1) 982166 2 off U-PKZ0(*V60Hz) 982163 A-PKZ0(24VDC)1) 073200 2 off A-PKZ0(110VDC)1) 073203 2 off 440 V 60 Hz 480 V 60 Hz 2 off Only A(U)-PKZ0... with serial number 02 or higher can be fitted 2 off Non-standard voltages not covered by above standard voltages The part number for ordering consists of the basic part number and the actuating voltage. For non-standard voltages, specify the required actuating voltage within the indicated range (... - ... V). Minimum order quantity is 10 units DC Standard voltage 24 V DC 110 V DC PKE can be fitted only with A(U)-PKZ0... with serial number 02 or higher. Information relevant for export to North America 1) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification UL 508; CSA-C22.2 No.14; IEC60947-4-1; CE marking E36332 NLRV 12528 3211-05 UL Listed, CSA certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 29 1.3 Engineering 1- and 2-pole-connected PKZM0, PKZM4 with AC and DC 2-pole-connected PKZM0(1) and PKZM4 with CL-PKZ0 L1 1 3 I> I> 2 4 5 1 3 I> I> I> 2 4 6 N 5 CL-PKZ0 4 2 I> 6 6 I >> I >> I >> 1 3 5 PKZ0Z 1 3 5 I> I> I> 2 4 6 Protection of PVC-insulated cables against thermal overload on short-circuits The table specifies which minimum conductor cross-sections are protected by motor-protective circuit-breaker PKZ(M) up to their rated conditional short-circuit current Iq. Min. cross-section protected 380 – 415 V, 50 Hz, Cu mm² 4 2.5 1.5 1 Device Part no. 0.75 ... PKZM0-0,16 PKZM0-6.3 PKZM0-10 PKZM0-12 PKZM0-16 PKZM0-20 PKZM0-25 PKZM0-32 PKZM4-16 PKZM4-25 PKZM4-32 PKZM4-40 PKZM4-50 PKZM4-58 PKZM4-63 PKZM0-...T tripping characteristics (not for PKM0-...), PKZM01 2h 20 min 5 PKZM4-... 10 5 2 2 1 40 1 40 20 10 20 10 s min s 2h 20 PKZM0-..., PKZM01 10 5 5 PKZM0...-T 2 2 1 1 200 200 20 x Iu 14 x I u ms 14 x Iu ms 1 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE 50 20 20 5 5 2 1.5 2 3 4 6 8 10 15 20 30 x Ir 30 50 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 2 1.5 2 3 4 6 8 10 15 20 x Ir 30 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE 1.3 t h Tripping characteristic curves, wide-range circuit-breaker PKE 2 1 1 PKE... min 20 10 5 2 1 s 20 10 5 CLASS20 CLASS15 CLASS10 CLASS5 2 1 500 200 12 x Ir ms 100 50 14 x Iu 20 10 5 2 1 1 1.5 2 3 4 5 7 10 15 20 30 40 50 70 100 x Ir Let-through characteristics, motor-protective circuit-breaker, transformer-protective circuit-breakers, circuit-breaker for starter combinations i2dt 10 5 8 [A 2 s] 6 4 3 4.0 A 2 1 0.8 0.6 1.6 A 0.2 1A 10 A/12 A 2 1.5 6.3 A 10 4 2.5 A 0.4 0.3 PKZM01 PKZM0-.... 32 A PKM0-.... 25 A 20 A 16 A f-w ave 32 A 25 A 20 A 16 A 10 A/12 A 6.3 A 10 PKZM0-.... 8 PKZM01-.... 6 PKM0-.... 4 I cc 2· 3 1 st hal ÎD [kA] 8 6 4.0 A 4 3 2 2.5 A 1.5 0.1 0.08 0.06 10 3 8 6 0.63 A 0.04 0.03 1.6 A 4 3 0.4 A 0.02 2 Ue = 400 V 0.015 0.01 1 1.5 2 3 4 6 8 10 15 20 30 40 Ue = 400 V 1.5 0.25 A 10 2 60 80100 1 1.5 2 3 4 6 8 10 Icc rms [kA] 15 20 1.0 A 30 40 60 80 100 Icc rms [kA] Motor-protective circuit-breaker let-through characteristics 100 6 i2dt 10 [A 2 s] PKZM4 1 st hal f -w ave PKZM4 63/58 A 50/40/32 A 25 A 16 A Ic c 10 5 2· ÎD [kA] 63/58 A 50/40/32 A 25 A 10 10 4 16 A 10 3 Ue = 400 V Ue = 400 V 1 10 2 1 10 100 Icc rms [kA] 1 10 100 Icc rms [kA] AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 31 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Switching capacity Circuit-breaker switching capacity from serial no. 04 1 Rated uninterrupted current Iu Rated conditional short-circuit current Iq IEC/EN 60947-4-1 Rated ultimate short-circuit breaking capacity Icu IEC/EN 60947-2 Rated breaking capacity Ics } Iu A 230 V Iq I cu kA kA I cs kA A1) 400 V Iq I cu kA kA I cs kA PKZM0, PKZM0...-T, PKM0 with type “1” and “2” coordination 150 150 150 N 150 150 150 0.16 – 1 1.6 150 150 150 N 150 150 150 2.5 150 150 150 N 150 150 150 4 150 150 150 N 150 150 150 6.3 150 150 150 N 150 150 150 10 150 150 150 N 150 150 150 12 50 50 13 50 50 50 13 16 50 50 13 50 50 50 13 20 50 50 13 50 50 50 13 25 50 50 13 50 50 50 13 32 50 50 13 50 50 50 13 PKZM0 (PKZM0...-T, PKM0) + CL-PKZ0 0.16 – 1 N 1.6 N 2.5 N 4 N 6.3 N 10 N 12 N 16 N 20 N 25 N 32 N PKZM0 (PKZM0...-T, PKM0) + 2 CL-PKZ0 0.16 – 1 N 1.6 N 2.5 N 4 N 6.3 N 10 N 12 N 16 N 20 N 25 N 32 N Notes No upstream protective device required, as it is the autoprotected range (100/150 kA) N 32 A1) N N N N N N 50 50 50 50 50 440 V Iq I cu kA kA 42 15 15 10 10 10 42 15 15 10 10 10 I cs kA A1) 12 12 12 13 13 13 N N N N N 50 50 50 50 50 50 N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N 1) 500 V Iq I cu kA kA 42 42 15 15 6 6 6 10 10 10 20 20 20 42 42 15 15 6 6 6 10 10 10 20 20 20 I cs kA A1) 11 11 8 8 3 3 3 N N N N 50 50 50 50 50 50 50 50 20 20 20 10 10 10 N N N N N N N N N N N 50 40 40 40 20 20 20 N N N N N N N N N N N 690 V Iq I cu kA kA 5 3 3 3 3 3 3 3 3 20 20 20 20 5 5 5 5 5 40 40 20 20 10 10 10 10 10 I cs kA A1) 5 3 3 3 3 3 3 3 3 5 3 2 2 2 2 1 1 1 N N 50 50 50 50 50 50 50 50 50 20 20 20 20 5 5 5 5 5 20 20 20 20 20 20 2.5 2.5 2.5 2.5 2.5 N N N N N N N N N N N 40 40 20 20 10 10 10 10 10 20 20 20 20 20 20 2.5 2.5 2.5 2.5 2.5 N N N N N N N N N N N Required back-up fuse if the short-circuit current exceeds the device's rated conditional short-circuit current (Icc > I q ). Not necessary AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Switching capacity Circuit-breaker switching capacity Rated uninterrupted current Iu Rated conditional short-circuit current Iq IEC/EN 60947-4-1 Rated maximum short-circuit breaking capacity Icu IEC/EN 60947-2 Rated breaking capacity Ics 1 } Iu A 230 V Iq I cu kA kA I cs kA A1) PKZM01 with type “1”and “2” coordination 0.16 – 1 50 50 50 50 1.6 50 50 50 50 2.5 50 50 50 50 4 50 50 50 50 6.3 50 50 50 50 10 50 50 50 50 12 50 50 10 50 16 50 50 10 50 20, 25 50 50 10 50 PKZM4 with type “1” and “2” coordination 150 150 25 N 16 25 150 150 25 N 32 50 50 25 100 40 50 50 25 100 50 50 50 25 100 58 50 50 25 160 63 50 50 25 160 PKE12...2) with type of coordination „1“ and 0.3 - 1.2 100 50 1-4 100 50 3 - 12 100 50 PKE32...2) with type of coordination „1“ and 3 - 12 100 50 8 - 32 100 50 Notes A1) 440 V 2) Iq I cu kA kA I cs kA A1) 50 50 50 50 50 50 10 10 10 50 50 50 50 50 50 50 50 50 50 50 50 50 50 42 15 15 10 50 50 50 50 50 42 15 15 10 50 50 50 50 50 10 10 10 3 50 50 50 50 50 50 50 50 50 25 25 25 25 25 25 25 N N 100 100 100 160 160 45 45 45 45 45 45 45 45 45 45 45 45 45 45 25 25 25 25 25 25 25 100 100 100 100 100 160 160 15 15 15 15 15 15 15 100 100 100 50 50 50 50 50 15 50 50 50 100 100 50 50 15 25 50 50 400 V Iq I cu kA kA I cs kA 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 150 150 50 50 50 50 50 150 150 50 50 50 50 50 No upstream protective device required,as it is the autoprotected range (150 kA) N Not necessary 500 V 2) Iq I cu kA kA A 1) 690 V 2) Iq I cu kA kA I cs kA A 1) 100 100 100 100 100 160 160 8 8 5 5 5 5 5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 100 100 100 100 100 160 160 10 10 10 50 50 50 3 3 3 50 50 50 6 6 50 50 3 3 50 50 15 15 15 15 15 15 15 I cs kA 8 8 5 5 5 5 5 1) Fuse (A gG/gL) for increasing the switching capacity of the motor-protective circuit-breaker to 100 kA 2) Please enquire for additional information regarding voltages >400 V and device combinations with CL-PKZ0. Motor-protective circuit-breaker internal resistances Impedance PKZM0-0,16 PKZM0-0.25 PKZM0-0.4 PKZM0-0.63 PKZM0-1 PKZM0-1.6 PKZM0-2.5 PKZM0-4 PKZM0-6.3 PKZM0-10 PKZM0-12 PKZM0-16 PKZM0-20 PKZM0-25 PKZM0-32 Rated uninterrupted current Iu Impedance ȍ Heat dissipation (3 pole at operating temperature) W A 78 32 13 5 2 0.8 0.32 0.13 0.050 0.020 0.014 0.008 0.005 0.003 0.002 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 12 16 20 25 32 PKZM4-16 PKZM4-25 PKZM4-32 PKZM4-40 PKZM4-50 PKZM4-58 PKZM4-63 Rated uninterrupted current Iu ȍ Heat dissipation (3 pole at operating temperature) W 0.029 0.012 0.007 0.005 0.003 0.002 0.002 22 22 22 22 22 22 22 16 25 32 40 50 58 65 A AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 33 1.3 1 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breakers PKZM Approvals for world markets PKZM01, PKZM0, PKZM4 Rating data for approved types 1) UL 508/CSA C 22.2 No. 14 Maximum motor rating Setting ranges Three-phase current Overload releases 200 V 230 V 460 V 575 V HP HP HP HP A Motor-protective circuit-breakers “Manual Motor Starter with thermal and magnetic trip” PKZM01 3) PKZM01-0,16 0.1 – 0.16 PKZM01-0.25 0.16 – 0.25 PKZM01-0.4 0.25 – 0.4 PKZM01-0,63 0.4 – 0.63 PKZM01-1 0.63 – 1 PKZM01-1,6 ¾ ¾ 1 – 1.6 PKZM01-2.5 ½ ½ 1 1½ 1.6 – 2,5 PKZM01-4 ¾ ¾ 2 3 2.5 – 4 PKZM01-6,3 1 1½ 3 5 4 – 6.3 PKZM01-10 3 3 7½ 10 6.3 – 11 PKZM01-12 3 3 7½ 10 9 – 12 PKZM01-16 3 5 10 10 10 – 16 PKZM01-20 5 15 16 – 20 PKZM01-25 7½ 15 20 20 – 25 Motor-protective circuit-breakers “Manual Motor Starter with thermal and magnetic trip” PKZM01 3) PKZM0-0,16 0.1 – 0.16 PKZM0-0.25 0.16 – 0.25 PKZM0-0.4 0.25 – 0.4 PKZM0-0.63 0.4 – 0.63 PKZM0-1 0.63 – 1 PKZM0-1.6 ¾ ¾ 1 – 1.6 PKZM0-2.5 ½ ½ 1 1½ 1.6 – 2,5 PKZM0-4 ¾ ¾ 2 3 2.5 – 4 PKZM0-6.3 1 1½ 3 5 4 – 6.3 PKZM0-10 3 3 7½ 10 6.3 – 11 PKZM0-12 3 3 7½ 10 9 – 12 PKZM0-16 3 5 10 10 10 – 16 PKZM0-20 5 15 16 – 20 PKZM0-25 7½ 15 20 20 – 25 PKZM0-32 7½ 10 20 25 24 – 32 Motor-protective circuit-breakers PKZM4 PKZM4-16 3 5 10 15 10 – 16 PKZM4-25 7½ 7½ 20 25 16 – 25 PKZM4-32 10 10 25 30 25 – 34 PKZM4-40 10 15 30 40 32 – 42 PKZM4-50 10 15 30 40 40 – 52 PKZM4-58 15 15 40 50 50 – 56 PKZM4-63 15 15 40 50 52 – 58 Notes Service factor (SF) Set value Ir , on the current scale, depending on the load factor SF = 1.15 J Ir = 1 x In mot SF = 1 J Ir = 0.9 x In mot 34 Short-circuitreleases AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1) 2) 3) Maximum protective device to UL/ CSA Group protection 2) Maximum Maximum Up to max. fuse rating circuit short-circuit breaker current 600 V with CL with CL A kA kA A 2.2 3.4 5.6 8.8 14 22 35 56 88 140 168 224 280 350 50 50 50 50 50 50 50 50 50 22 18 10 10 10 50 50 50 18 18 600 600 600 600 600 600 600 600 600 150 150 150 150 150 2.2 3.4 5.6 8.8 14 22 35 56 88 140 168 224 280 350 448 50 50 50 50 50 50 50 50 50 22 18 10 10 10 10 50 50 50 18 18 18 600 600 600 600 600 600 600 600 600 150 150 150 150 150 150 with CL A A A 600 600 600 600 600 600 600 600 600 600 600 600 600 600 125 125 125 125 125 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 125 125 125 125 125 125 600 600 600 600 600 600 224 50 600 600 350 50 600 600 448 50 600 600 560 50 600 600 700 10 600 600 812 10 600 600 882 10 600 600 Devices for world markets IEC UL/CSA Caution: Changed requirements for group protection Calculate motor output in this range according to rated operational current. Specified values as per NEC Table 430 – 150 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Type E starters 1.3 PKZM 1 Rating data for approved types1) UL 508/CSA C 22.2 No. 14 Accessories Standard auxiliary contacts NHI11-PKZ0 Early-make auxiliary contacts Trip indicators Shunt release Auxiliary contact for contact module For use with Pilot Duty General Use PKZM0(-T) PKZM4 A 600, Q 300 5 A – 600 V AC 1 A – 250 V DC – E150 0.5 A – 250 V AC – NHI12-PKZ0 NHI21-PKZ0 NHI2-11S-PKZ0 NHI-E-11-PKZ0 NHI-E-10-PKZ0 VHI20-PKZ0 VHI20-PKZ01 AGM2-10-PKZ0 AGM2-01-PKZ0 A-PKZ0(...) U-PKZ0(...) PKZM0(-T) PKZM01 PKZM0(-T) PKZM4 E150 E150 A 600, Q 300 0.5 A – 250 V AC 0.5 A – 250 V AC 5 A – 600 V AC 1 A – 250 V DC – – – PKZM0(-T) PKZM4 – – HI11-S/EZ-PKZ0 PKZM0 A 600, Q 300 5 A – 600 V AC 1 A – 250 V DC Actuating voltages and ordering information Products for the German market – 1) Notes Devices for world markets IEC UL/CSA PKZM Motor-protective circuit-breakers PKZM0(4) used as "Manual self-protected Motor Starters" – UL 508 Type E Maximum motor output Setting ranges Interrupting Capacity = AC Short Circuit Current (SCCR) 200 V 230 V 460 V 575 V Overload Short-circuit 240 V 480Y/ 600Y/ 208 V 240 V 480 V 600 V releases releases 277 V 2) 347 V 2) Motor Protector Accessories [HP] [HP] [HP] [HP] [A] [A] [kA] [kA] [kA] Part no. Part no. ¾ 1½ 3 5 10 – – – – – 10 20 30 30 – – – 0.1 – 0.16 0.16 – 0.25 0.25 – 0.4 0.4 – 0.63 0.63 – 1 1 – 1.6 1.6 – 2,5 2.5 – 4 4 – 6.3 6.3 – 11 9 – 12 10 – 16 16 – 20 20 – 25 24 – 32 10 – 16 16 – 27 24 – 34 32 – 40 40 – 52 50 – 56 52 – 58 2.2 3.4 5.6 8.8 14 22 35 56 88 140 168 224 280 350 448 224 350 448 560 700 812 882 65 65 65 65 65 65 65 65 65 65 65 42 18 18 18 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 42 18 18 18 65 65 65 65 65 65 – 50 50 50 50 50 50 50 50 50 50 – – – – – 25 25 25 25 – – – PKZM0-0.16 PKZM0-0.25 PKZM0-0.4 PKZM0-0.63 PKZM0-1 PKZM0-1.6 PKZM0-2.5 PKZM0-4 PKZM0-6.3 PKZM0-10 PKZM0-12 PKZM0-16 PKZM0-20 PKZM0-25 PKZM0-32 PKZM4-16 PKZM4-25 PKZM4-32 PKZM4-40 PKZM4-50 PKZM4-58 PKZM4-63 BK25/3-PKZ0-E BK25/3-PKZ0-E BK25/3-PKZ0-E BK25/3-PKZ0-E BK25/3-PKZ0-E BK25/3-PKZ0-E BK25/3-PKZ0-E BK25/3-PKZ0-E BK25/3-PKZ0-E BK25/3-PKZ0-E BK25/3-PKZ0-E BK25/3-PKZ0-E BK25/3-PKZ0-E BK25/3-PKZ0-E BK25/3-PKZ0-E BK50/3-PKZ4-E BK50/3-PKZ4-E BK50/3-PKZ4-E BK50/3-PKZ4-E BK50/3-PKZ4-E BK50/3-PKZ4-E BK50/3-PKZ4-E 1) ½ ¾ 1 3 3 3 5 – 7½ 3 5 7½ 10 – – – Notes ½ ¾ 1½ 3 3 5 – 7½ 10 5 7½ 10 – 15 – – ¾ 1 2 3 7½ 7½ 10 – 15 20 10 15 20 30 30 40 40 Components 1) 2) Calculate motor power in this range according to the rated current. Stated values to NEC Table 430 -150 Suitable for networks with grounded star-point AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 35 1.3 Motor-protective circuit-breaker Technical data PKZM, PKE PKZM0-…1) PKZM01… General Standards Climatic proofing IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Storage Open °C °C -25…80 -25…55 -25 …80 -25…55 Encapsulated °C -25…40 -25…40 ° 90 ° ° 90 Built-in position 90 1 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Direction of incoming supply Degree of protection Any IP20 Any IP20 IP00 Finger- and back-of-hand proof IP00 AWG mm² 25 max. 2000 1 x (1 - 6) 2 x (1 - 6) 1 x (1 - 6) 2 x (1 - 6) 18 - 10 – mm² – AWG Nm – 1.7 25 max. 2000 1 x (1 - 6) 2 x (1 - 6) 1 x (1 - 6) 2 x (1 - 6) 18 - 10 1 x (1…2.5) 2 x (1…2.5) 1 x (1…2.5) 2 x (1…2.5) 18…14 1.7 Nm 1 1 U imp V AC Ue Iu = I e V AC A Operations Operations Operations/h Hz W x 10 6 x 10 6 Ops/h 6000 III/3 690 16 or current setting of the overcurrent release 40 - 60 6 0.05 0.05 25 6000 III/3 690 32 or current setting of the overcurrent release 40 - 60 6 0.1 0.1 40 kA 60 Page 32 60 (up to PKZM0-16) 40 (PKZM0-20 to PKZM0-32) AC-3 up to 690 V DC-5 (up to 250 V) Trip blocks Temperature compensation A A 16 16 (3 contacts in series) 32 25 (3 contacts in series) To IEC/EN 60947, VDE 0660 Operating range Temperature compensation residual error for T > 40 °C Setting range of overload releases °C °C %/K x Iu -5…40 -25…55 ̰0.25 0.6 - 1 -5…40 -25…55 ̰0.25 0.6 - 1 Short-circuit releases tolerance Phase-failure sensitivity % ± 20 IEC/EN 60947-4-1, VDE 0660 Part 102 ± 20 IEC/EN 60947-4-1, VDE 0660 Part 102 Device Terminals Contact protection to EN 50274 Shock resistance, half-sinusoidal shock, 10 ms to IEC 60068-2-27 I n s ta lla tio n a ltitu d e Terminal capacity, screw terminals Solid Terminal capacity, spring-loaded terminals Flexible with ferrule to DIN 46228 Solid or stranded Solid Terminal screw tightening torque Flexible with ferrule to DIN 46228 Solid or stranded Main conductors Auxiliary conductors Main contacts Rated impulse withstand voltage Overvoltage category/pollution degree Rated operational voltage Rated uninterrupted current = rated operational current Rated frequency Heat dissipation (3 pole at operating temperature) Lifespan, mechanical Lifespan, electrical (AC-3 at 400 V) Maximum operating frequency Short-circuit rating g m mm² mm² AC DC Page 33 Motor switching capacity Notes 36 1) Tested according to IEC/EN 60947-1 (isolating characteristics) and IEC/EN 60947-2 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker 1.3 1 PKM0-… PKZM0-…-T PKZM4 PKE IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 -25…80 -25…55 -25…40 -25…40 -25…40 -25…40 90 90 90 ° 90 ° ° ° 90 90 90 ° -25…70 -25…55 ° -25…80 -25…55 ° -25…80 -25…55 Any IP20 Any IP20 Any IP20 Any IP20 IP00 Finger- and back-of-hand proof IP00 IP00 IP00 25 max. 2000 1 x (1 - 6) 2 x (1 - 6) 1 x (1 - 6) 2 x (1 - 6) 18 - 10 1 x (1…2.5) 2 x (1…2.5) 1 x (1…2.5) 2 x (1…2.5) 18…14 1.7 25 max. 2000 1 x (1 - 6) 2 x (1 - 6) 1 x (1 - 6) 2 x (1 - 6) 18 - 10 – 15 max. 2000 1 x (1 - 50) 2 x (1 - 35) 1 x (1 - 35) 2 x (1 - 35) 14 - 2 – – – – 1.7 – 3.3 25 max. 2000 1 x (1 - 6) 2 x (1 - 6) 1 x (1 - 6) 2 x (1 - 6) 18 - 10 1 x (1…2.5) 2 x (1…2.5) 1 x (1…2.5) 2 x (1…2.5) 18…14 1.7 1 1 1 1 6000 III/3 690 32 or current setting of the overcurrent release 40 - 60 6 0.1 0.1 40 6000 III/3 690 25 or current setting of the overcurrent release 40 - 60 6 0.1 0.1 40 6000 III/3 690 65 Open 63 enclosed 40 - 60 22 0.03 0.03 40 6000 III/3 690 32 A or set current of the overcurrent release 40 - 60 6 0.05 0.05 60 Page 32 60 (up to PKM0-16) 40 (PKM0-20 to PKM0-32) Page 32 60 (up to PKZM0-16) 40 (PKZM0-20 to PKZM0-32) 60 – 32 25 (3 contacts in series) 25 25 (3 contacts in series) 65 63 (3 contacts in series) 32 – -5…40 -25…55 ̰0.25 -5…40 -25…55 ̰0.25 0.6 - 1 -5…40 -25…55 ̰0.25 0.6 - 1 -5…40 -25…55 ± 20 – ± 20 IEC/EN 60947-1-1, VDE 0660 Part 102 ± 20 IEC/EN 60947-4-1, VDE 0660 Part 102 ± 20 Yes Page 33 Page 33 0.25 - 1 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 37 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Auxiliary contacts 1 NHI...PKZ, AGM, U-PKZ, A-PKZ NHI…PKZ0 NHI-E-…PKZ0 VHI…PKZ0 AGM Auxiliary contacts Rated impulse withstand voltage Overvoltage category/pollution degree Rated operating voltage U imp V AC 6000 III/3 4000 III/3 4000 III/3 6000 III/3 Ue V AC 500 440 440 500 Ue V DC 250 250 250 250 V AC 690 690 690 690 Safe isolation according to EN 61140 Between auxiliary contacts and main contacts Rated operational current AC-15 220 - 240 V Ie A 3.5 1 1 3.5 380 - 415 V 440 - 500 V Ie Ie A A 2 1 – – – – 2 1 24 V Ie A 2 2 2 2 60 V Ie A 1.5 – – 1.5 110 V 220 V Ie Ie A A 1 0.25 – – – – 1 0.25 Operations x 10 6 > 0.1 > 0.1 > 0.1 > 0.01 Operations Fault probability x 10 6 > 0.05 > 0.1 > 0.1 > 0.05 DC-13 L/R̰100 ms Durability Lifespan, mechanical Lifespan, electrical Control circuit reliability (at Ue = 24 V DC, Umin = 17 V, I min = 5.4 mA) Interlocked opposing contacts < 10 -8 < 1 failure in 1 x 10 8 operations Yes – – – A gG/gL FAZ-B4/1-HI 10 – 10 – 10 FAZ-B4/1-HI 10 mm² AWG 0.75 - 2.5 18 - 14 0.75 - 1.5 18 - 16 0.75 - 1.5 18 - 16 0.75 - 2.5 18 - 14 Short-circuit rating without welding Fuseless Fuse Terminal capacity Solid or flexible conductor with ferrule Solid or stranded NHI...PKZ, AGM, U-PKZ, A-PKZ Undervoltage release U-PKZ... Shunt release A-PKZ... 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (18 - 14) 2 x (18 - 14) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (18 - 14) 2 x (18 - 14) General Terminal capacity Solid or flexible conductor with ferrule mm² Solid or stranded AWG Main contacts Rated operating voltage Ue V AC 42 - 480 42 - 480 Rated operating voltage Ue V DC 24 - 250 24 - 250 Pick-up-/drop-out voltage Pick-up voltage x Us 0.85 - 1.1 Drop-out voltage Operating range x Us 0.7 - 0.35 AC voltage x Us 0.7…1.1 DC voltage (intermittent operation 5 s) Power consumption x Us 0.7…1.1 AC voltage AC pick-up rating Pick-up VA 5 5 AC consumption when closed Holding VA 3 3 DC pick-up rating Pick-up W – 3 DC consumption when closed Holding W – 3 DC voltage 38 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker Dimensions 1 Motor-protective circuit-breaker 45 93 PKZM01… 45 5.5 44 74 85 Motor-protective circuit-breaker Transformer-protective circuit-breakers Motor-protective circuit-breaker with standard auxiliary contacts Motor-protective circuit-breakers with lockable rotary handles PKZM0-…+AK-PKZ0 PKZM0-…(+NHI-E-…-PKZ0) PKZM0-…-T(+NHI-E-…-PKZ0) PKM0-…(+NHI-E-…-PKZ0) 70 93 45 45 55 93 4.5 AK-PKZ 0 AK-PKZ 0 NHI-E-..-PKZ0 45 NHI-E-..-PKZ0 25 45 88 94 Motor-protective circuit-breakers with early-make auxiliary contacts CL-PKZ… PKZM0-…+VHI-…-PKZ0 45 80 93 73 93 45 28 55 Current limiters 90 50 50 68 76 VHI...-PKZ0 7.5 44 49.5 7.5 VHI...-PKZ0 70 50 45 68 Top-hat rail IEC/EN 60715 NHI…-PKZ0 AGM2…-PKZ0 A-PKZ0… U-PKZ0… 9 9 68 26 18 68 45 90 45 90 45 26 36 Shunt release Undervoltage release 36 Trip indicators 36 Standard auxiliary contacts 90 86 49 68 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 39 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Busbar adapters BBA2-63 BBA2-63/2TS BBA4/2TS-L BBA4L-63 45 10 60 10 72 35 35 BBA2-63/2TS BBA2-63 63 63 10 55 BBA0/2TS-L BBA0-25 BBA0-32 35 BBA4L-63 BBA4/2TS-L BBA2-80/2TS-S BBA2L-63 40 60 260 60 60 214 200 60 60 40 40 BBA4-63 63 60 BBA0-32/2TS-C BBA0-25/2TS BBA0C-16 60 260 60 60 200 200 60 60 40 40 BBA0-25/2TS BBA0/2TS-L BBA0-32 BBA0-32/2TS-C BBA0C-16 40 1 BBA0-25 10 55 72 35 10 35 63 63 72 10 35 63 BBA0K-32 PKZM0-XC45L PKZM0-XC45L-2 283 60 60 260 161 60 60 20 40 BBA0L-25 BBA0L-32 10 45 35 63 45 BBA0L-25 BBA0L-32 40 10 35 63 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 45 PKZM0-XC45L PKZM0-XC45L-2 10 20 40 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories Insulated enclosures for surface mounting 1 70 158 CI-PKZ10G...M 158 CI-PKZ0-M 80 80 97.5 125.5 90 100 CI-PKZ0-…M + SVB-PKZ0-CI Drilling dimensions CI-PKZ0-…M 98 30 28 97.5 44 4.5 33 30 55 8 153 158 SVB-PKZ0-CI 4.5 80 47.5 100 181 160 181 CI-K2-PKZ0G(R)(V) 160 CI-K2-PKZ0 47.5 100 104 103 130 CI-K2-PKZ0-G(R)(V) + SVB-PKZ0-CI Drilling dimensions CI-K2-PKZ0… 98 30 114 28 M4 44 33 30 171 55 160 181 SVB-PKZ0-CI 97 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical M4 41 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories Door coupling handles Mounting depth: 100 to 240 mm from the top edge of the top-hat rail to the front edge of the cabinet door/cover Distance between switch axis and cover hinge: at least 100 mm 48 64 PKZ0-X(R)H… 7.5 64 20 54 48 At least 100 mm from cover hinge IInsulated enclosures for flush mounting E-PKZ0 Mounting aperture E-PKZ0… E-PKZ0-G… R4 116 – 118 55 129 69 80 96 124 85 70–72 E-PKZ0-G… + SVB-PKZ0-E 98 98 30 58 58 30 30 55 55 129 21 28 80 80 85 96 96 124 124 Insulated enclosures for surface mounting Mounting plates CI23E… M3-CI23 142.5 3 3 147 177 35 144 147 177 56 7 114 225 262 278 62.5 205 162 knockout 60 200 90 114.5 84.5 114.5 84.5 14 215 92 92 14 8 x PG 16 2 x PG 21/29 125 25 250 187.5 25 27 27 1 6 × PG 16 1 × PG 21/29 42 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories Insulated enclosures for surface mounting CI-PKZ01-SVB CI-PKZ01-SVB-V 158 80 116.5 80 1 158 CI-PKZ01-PVT CI-PKZ01-PVS 158 CI-PKZ01 CI-PKZ01-G 116.5 80 177.2 116.5 129.5 Insulated enclosures for flush mounting E-PKZ01 E-PKZ01-G E-PKZ01-PVT E-PKZ01-PVS 69 129 129 69 90.2 90.2 93 93 115.2 115.2 175.9 E-PKZ01-SVB E-PKZ01-SVB-V 129 69 90.2 93 115.2 128.2 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 43 1.3 Accessories Motor-protective circuit-breaker Standard auxiliary contacts PKZM4-… NHI…-PKZ… NHI…-PKZ0 90 45 125 45 53 140 130 65 36 4 26 9 68 30 7.5 NHI-E... NHI-E... 118 55 127 145 160 Motor-protective circuit-breakers with lockable cover Tripindicators PKZM4-… +AK-PKZ0 AGM2…-PKZ… AGM2…-PKZ0 90 65 125 45 140 130 AK-PKZ0 45 36 4 9 26 68 7.5 30 118 55 127 145 171 PKE Motor-protective circuit-breakers PKE12 , PKE32 PKE65 118 25 14.5 102.5 45 35 5.5 55 127 172 187 44 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 32.5 160 56.5 100.5 101 1 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories 1.3 Three-phase commoning links B3.2/4-PKZ4 1 14 14 36 36 B3.0/4-PKZ4 33 205 260 B3.2/2-PKZ4 14 14 36 36 B3.0/3-PKZ4 33 151 115 33 B3.0/3-PKZ4 14 14 36 36 B3.0/2-PKZ4 33 98 33 170 B3.1/2-PKZ4 14 14 36 36 B3.1/4-PKZ4 33 232 33 117 33 Three-phase commoning links Three-phase commoning links B3.0/4-PKZ0 B3.0/2-PKZ0 B3.2/4-PKZ0 B3.2/2-PKZ0 234 180 (90) H-B3PKZ 0 H-B3PKZ0 27 45 27 63 Three-phase commoning links Incomingterminals B3.1/5-PKZ0 B3.1/4-PKZ0 BK25/3-PKZ0 Overlapping mounting to extend the three-phase commoning link 261 (207, 153, 99) H-B3PKZ 0 ̰ 56 31 BK25/3-PKZ0 48 27 7.5 73 B3.1/3-PKZ0 B3.1/2-PKZ0 54 ̰ 41 B3...-PKZ0 62 94 Motor plug DILM12-XMCP/T 27 85 45 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 45 1.3 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories 1 Insulated enclosures for surface mounting CI-K4-PKZ4-G(R) +SVB-PKZ4-CI CI-K4-PKZ4-G 98 240 3 32 72 SVB-PKZ4-CI 160 134 181 197 Drilling dimensions CI-K4-PKZ-G(R) 160 186 28 30 46 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 193 240 240 72 Ø 5.6 142 DC string circuit-breakers, DC switch-disconnectors 1.3 Description 1 P-SOL, PKZ-SOL, SOL DC string circuit-breaker PKZ-SOL DC switch-disconnector P-SOL Ready-to-install DC switchdisconnector SOL Inverter module AC main switch Network Photovoltaics description Features Photovoltaic systems convert sunlight directly into electrical energy using solar cells. Photovoltaics represent a renewable source of energy that can be used on private and public buildings, as well as in large-scale power stations. These systems can be independent from the power grid or can be connected to it. Photovoltaic systems that are connected to the grid feed the generated power directly into the mains network. This eliminates the need for temporary storage. These systems consist of solar cells, one or more inverters, and a protective device for automatic cutoff in the event of a grid fault. Because of this, photovoltaic systems that are connected to the grid require extremely reliable and safe individual components. DC string circuit-breakers • Protect PV modules from fault currents, prevent (in larger systems, for instance) intact modules from feeding power back into a module with a short-circuit. • Are ready for operation immediately after tripping and after the trip cause has been fixed. • Open and for installation in customized generator terminal boxes. • Tripping currents are adjustable within a wide range of limits. • Optional shunt releases A-PKZ0 and undervoltage releases U-PKZ0 enable remote shutdown, e.g for the fire department. Optional auxiliary contact NHI-E-PKZ0 signals switching state. • When installed in an enclosure, suitable for voltages of up to 900 VDC. DC switch-disconnectors • Required, according to standard VDE 0100-712 (June 2006), between the PV module and inverter. • Enclosed and open (for installation in enclosure) switch-disconnectors for voltages of up to 1,000 VDC. • Usable as a separate switching point as required in VDI Guideline VDI 6012, e.g. by de-energizing an inverter in a completely safe manner. • Two-pole switching, making it suitable for non-earthed systems as well. • TÜV-certified. • Open switch-disconnectors P-SOL are designed for installation in customer-specific enclosures or inverters. • Mounting on 35 mm top-hat rails, their terminals enable a connection to all popular cable types. • Separate rotary handles and shaft extensions allow for flexible installation. • An auxiliary switching block can be mounted in order to provide switching state feedback. • A shunt release or undervoltage release is available for remote tripping. • Switch-disconnectors SOL with enclosure are ready for installation. Models for 2 and 4 or 4 and 8 strings and for the most popular connector types, such as MC3, MC4, and metric screw connectors, allow for easy integration into various system concepts. • Enclosure provides degree of protection IP65, making outdoor mounting possible. • Lockable mechanism provides safety when maintenance is required. • Pressure-equalizing element prevents the formation of condensed water, preventing failures caused by voltage sparkovers. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 47 1.3 1 DC string circuit-breakers, DC switch-disconnectors DC switch-disconnectors, ready to install Ordering DC switch-disconnector, ready-to-install Inputs Number of strings Outputs Connection type Number of strings Connection type Max. rated operational current DC-21A Ie Part no. Article no. Price See price list Std. pack A Rated operational voltage Ue 1000 V Degree of protection IP65 Protection class 2 2 pole SOL20/2MC3 120913 SOL20/4MC3 120914 1 off 20 SOL20/2MC4 120915 1 off MC4 20 1 off 1 Screw connector M16 20 SOL20/4MC4 120916 SOL20/2MV 120919 MC3 1 MC3 30 SOL30/2MC3 120920 1 off 4 MC3 1 MC3 30 1 off 2 MC4 1 MC4 30 SOL30/4MC3 120921 SOL30/2MC4 120922 4 MC4 1 MC4 30 SOL30/4MC4 120923 1 off 2 Screw connector M12 1 Screw connector M16 30 SOL30/2MV 120926 1 off 4 MC3 1 Screw connector M20 63 SOL60/4MC3 120927 1 off 8 MC3 1 Screw connector M20 63 SOL60/8MC3 120928 1 off 4 MC4 1 Screw connector M20 63 SOL60/4MC4 120929 1 off 8 MC4 1 Screw connector M20 63 SOL60/8MC4 120930 1 off 4 Screw connector M12 1 Screw connector M20 63 SOL60/4MV 120933 1 off 2 MC3 1 MC3 20 4 MC3 1 MC3 20 2 MC4 1 MC4 4 MC4 1 2 Screw connector M12 2 Information relevant for export to North America NA Certification 48 Request filed for UL and CSA AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1 off 1 off 1 off DC string circuit-breakers, DC switch-disconnectors 1.3 P-SOL, PKZ-SOL Max. rated operational current DC-21A Ie A 1 Permissible solar module short-circuit currents DC switch-disconnector, open Rated operating voltage Ue 1000 V Protection class II 2 pole 20 Part no. Article no. Price See price list Std. pack P-SOL20 120934 1 off 30 P-SOL30 120935 1 off 63 P-SOL60 120936 1 off DC string circuit-breakers Rated operating voltage Ue 900 V Protection class II 2 pole 12 5 - 9 PKZ-SOL12 120937 1 off 20 9 - 15 PKZ-SOL20 120938 1 off 30 15 - 22 PKZ-SOL30 120939 1 off 40 22 - 30 PKZ-SOL401) 120940 1 off 50 29 - 38 PKZ-SOL501) 120941 1 off 60 38 - 47 PKZ-SOL601) 120942 1 off 1) Notes Availability from November 2010 1 1 3 2 3 2 Accessories 2 Auxiliary contacts NHI-E 3 Shunt releases A-PKZ0 3 Undervoltage releases U-PKZ0 Page 10 29 29 Information relevant for export to North America NA Certification Request filed for UL and CSA AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 49 1.3 1 DC string circuit-breakers, DC switch-disconnectors Engineering P-SOL and PKZ-SOL wiring Switch-disconnector P-SOL Non-earthed grid String circuit-breaker PKZ-SOL Non-earthed grid Earthed grid Earthed grid 1000 VDC 1000 VDC 900 VDC 900 VDC 1 3 5 1 3 5 1 3 5 1 3 5 2 4 6 2 4 6 2 4 6 2 4 6 SOL internal circuit SOL20/2MV SOL30/2MV SOL20/2MC3 SOL20/2MC4 SOL30/2MC3 SOL30/2MC4 Input + Strings 1 Input (M12) + Strings - Strings 3 5 1 3 4 6 2 Input Input + Strings - Strings + Strings - Strings - Strings 5 1 2 SOL60/4MC3 SOL60/4MC4 SOL20/4MC3 SOL20/4MC4 SOL30/4MC3 SOL30/4MC4 4 3 1 5 3 5 6 + 2 2 + + Output 4 + SOL60/4MV Input Input (M12) + Strings - Strings 1 3 5 + 2 4 6 + Output (M20) Output SOL60/8MC3 SOL60/8MC4 + Strings - Strings 1 3 5 2 4 6 + - 6 + Output (M20) 50 4 6 Output (M16) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical + Output (M20) DC string circuit-breakers, DC switch-disconnectors Characteristic curves 1.3 Tripping characteristics 1 Tripping characteristics DC string circuit-breaker PKZ-SOL t [s] 10.000 2h 1h 1.000 100 (1 min) 10 1 0.1 0.01 0.001 1 100 x Ir 10 Characteristic curve set value short-circuit current As specified in the IEC 62548-1 draft for the protection of photovoltaic modules, the tripping current of the circuit- breaker must lie between 1.4 and 2 times the value of the photovoltaic module‘s short-circuit current. Since only the current values of the installed overload release can be plotted on the setting scale for the circuit-breaker1), the correlation between the protective device‘s tripping current and the photovoltaic module‘s short-circuit current must be specified for each point of the scale in a suitable form. Setting aid for string circuit-breaker PKZ-SOL Ir 70 PKZ-SOL60 60 Set value on circuit-breaker [A] 50 PKZ-SOL50 40 PKZ-SOL40 30 20 PKZ-SOL30 PKZ-SOL20 PKZ-SOL12 PKZ-SOL7 PKZ-SOL4 0 0 5 10 15 20 25 30 10 35 40 45 50 ISC... [A] Short-circuit current in solar module [A] 1) Standard IEC/EN 60947-2 (Section 4.7.3) prohibits directly specifying the photovoltaic short-circuit current on the circuit-breaker's setting scale, meaning that only the current set value of the operating current can be plotted there. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 51 1.3 DC string circuit-breakers, DC switch-disconnectors DC switch-disconnectors Technical data 1 P-SOL, SOL SOL20 Rated operational current Ie at DC-21A Number of poles Rated operational voltage U e Isolating characteristics Standards A V DC Lifespan mechanical Lifespan electrical Max. operating frequency, mechanical Climatic proofing Operations Operations Ambient temperature Mounting position Degree of protection min./max. Ops/h °C IP Dimensions Width Height Depth Weight Lockable in OFF position Rated short-time withstand current , 1 s to EN 60947-3 Rated short-circuit making capacity to EN 60947-3 Internal resistance mm mm mm kg SOL30 SOL60 20 30 2 2 1000 1000 Yes Yes IEC/EN 60 947-3 UL 508, TÜV certificate 100,000 100,000 100,000 100,000 120 120 Damp heat, constant, to IEC 60 068-2-78 Damp heat, cyclic, to IEC 60 068-2-30 -25 ... +60 -25 ... +60 Any Any 65 65 63 2 1000 Yes 100 215 130 0.42 Yes 0.36 160 305 210 2.2 Yes 0.72 30,000 30,000 120 -25 ... +60 Any 65 I cw kA 100 215 130 0.42 Yes 0.24 I cm kA 0.32 0.32 0.6 mȍ 8 7 4 P-SOL20 P-SOL30 P-SOL60 Ie A Ue V DC 20 30 2 2 1000 1000 Yes Yes IEC/EN 60 947-3 UL 508, TÜV certificate 100,000 100,000 100,000 100,000 120 120 Damp heat, constant, to IEC 60 068-2-78 Damp heat, cyclic, to IEC 60 068-2-30 63 2 1000 Yes °C -25 ... +60 Any -25 ... +60 Any -25 ... +60 Any mm mm mm 58 93 76 58 93 76 55 140 160 35 mm – 35 mm – kg 0.32 0.32 35 mm 2 x M4 x 18 30 x 130 1.25 I cw mm² mm² AWG kA 1 x (1-6) 2 x (1-6) 18 - 14 0.24 1 x (1-6) 2 x (1-6) 18 - 14 0.36 1 x (1-35) 2 x (1-35) 14 - 2 0.72 I cm kA 0.32 0.32 0.6 mȍ 6 5 3 P-SOL, SOL Rated operational current at DC-21A Number of poles Rated operational voltage Isolating characteristics Standards Lifespan mechanical Lifespan electrical Max. operating frequency, mechanical Climatic proofing Ambient temperature Open Mounting position Dimensions Width Height Depth Mounting Top-hat rail Screw mounting Operations Operations Ops/h min./max. Weight Terminals Flexible with ferrule solid/stranded Rated short-time withstand current , 1 s to EN 60947-3 Rated short-circuit making capacity to EN 60947-3 Internal resistance 52 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 30,000 30,000 120 1.3 DC string circuit-breakers, DC switch-disconnectors DC string circuit-breakers, open PKZ-SOL PKZ-SOL12 PKZ-SOL20 PKZ-SOL30 PKZ-SOL40 PKZ-SOL50 PKZ-SOL60 20 30 40 50 63 Rated operational current at DC-21A/750VDC Number of poles Ie A 12 2 2 2 2 2 2 Rated operational voltage Ue V DC 900 900 900 900 900 900 -25 ... +60 -25 ... +60 -25 ... +60 Thermal tripping 1.05 ...1.3 x I e 6 x Ie Electromagnetic tripping Standards IEC/EN 60 947-2 UL 508, TÜV certificate Climatic proofing Ambient temperature Open 1 Damp heat, constant, to IEC 60 068-2-78 Damp heat, cyclic, to IEC 60 068-2-30 min./max. °C -25 ... +60 -25 ... +60 -25 ... +60 90 ° ° 90 90 ° Mounting position PKZ-SOL12 to PKZ-SOL60 PKZ-SOL12 to PKZ-SOL30 Dimensions Width mm 58 58 58 55 55 55 Height Depth mm mm 93 76 93 76 93 76 140 160 140 160 140 160 Mounting Top-hat rail 35 mm 35 mm 35 mm 35 mm 35 mm 35 mm – – – kg 0.32 0.32 0.32 2 x M4 x 18 30 x 130 1.25 2 x M4 x 18 30 x 130 1.25 2 x M4 x 18 30 x 130 1.25 mm² mm² 1 x (1-6) 1 x (1-6) 1 x (1-6) 1 x (1-35) 1 x (1-35) 1 x (1-35) 2 x (1-6) 18 - 14 31 2 x (1-6) 18 - 14 12 2 x (1-6) 18 - 14 7 2 x (1-35) 14 - 2 – 2 x (1-35) 14 - 2 – 2 x (1-35) 14 - 2 – Screw mounting Weight Terminals flexible with ferrule solid/stranded Internal resistance AWG mȍ AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 53 1.3 DC string circuit-breakers, open Dimensions P-SOL, PKZ-SOL, SOL P-SOL20 P-SOL30 PKZ-SOL12 PKZ-SOL20 PKZ-SOL30 P-SOL60 PKZ-SOL40 PKZ-SOL50 PKZ-SOL60 NHI-E... 58 43.5 62 5.5 30 NHI-E... 7.5 118 55 70 127 145 160 SOL 100 246 130.5 160 Connection type b mm Connection type b mm MC3 MC4 MV 195 234 224 MC3 MC4 MV 275 314 304 54 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical b SOL60 b SOL20 SOL30 215 125 45 53 130 140 65 92.5 45 4 180.3 1 DC switch-disconnectors, DC string circuit-breakers 1 Motor-starter combinations Combining a motor protective circuit breaker or circuit breaker with a contactor results in a motor starter according to coordination type "1" or "2". Both types of coordination safely control short-circuit by switching it off. Coordination type "2" starters offer a high degree of operational continuity: after the cause of the short circuit has been removed, they can be switched back on immediately. Motor-starter combination - motor starter up to 1400 A • Highest safety through proven combination in coordination type "1" or "2" • Approved combinations for export to North America DOL starter and reversing starter MSC… – motor starter with motor-protective circuit-breaker PKZM0 up to 32A • • • • Mounted starters minimize wiring time Plug & Play with starters on busbar adapters Attractive design for high-quality installations Direct field bus connection through SmartWire-DT® communication system via plug-in type protective module DOL starter and reversing starter MSC-DE… – motor starter with electric motor-protective circuit-breaker PKE up to 32A • Increased safety through separate contact systems between switching and safety devices • Direct field bus connection through SmartWire-DT® communication system via plug-in type protective module • Direct reading of motor current and state, transfer to subordinate control system through SmartWire-DT® Conditions for fulfilling type of coordination • • • • • • • • Coordination type: "1": Secure switching off of the entered short-circuit current lq No danger to personnel or installations in case of short-circuit For further operation without repair and partial renewal, switch does not need to be suitable Damage to the switch or individual components approved Coordination type: "2": Secure switching off of the entered short-circuit current lq No danger to personnel or installations in case of short-circuit Switch remains suitable for further operation No damage to switch, except to welds of protective contacts, when these can be easily separated without significant deformation AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Motor-starter combinations Contents Ordering Direct-on-line starters MSC-D MSC-D complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 MSC-US complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 MSC-DEA complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Modules PKZM0/PKZM4 + DILM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Modules NZMN/NZMH + DILM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Modules PKM0 + DILM + ZB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Modules NZMN + DILM + ZB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Ordering Reversing starter MSC-R MSC-R complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Modules PKZM0/PKZM4 + DILM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Modules NZMN/NZMH + DILM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Ordering Starter on busbar adapter DOL starter complete units MSC-D/BBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Reversing starters complete units MSC-R/BBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Ordering Starter for North America Modules type F starter combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Modules DILEM/DILM + ZE/ZB/Z5/ZW7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Modules NZMH-…-CNA + DILM + ZB/Z5/ZW7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 System overview, description Connection system SmartWire-DT® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Ordering Connection system SmartWire-DT® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Engineering Connection system SmartWire-DT® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Technical data Connection system SmartWire-DT® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 DOL starters MSC-D, MSC-DE(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Reversing starter MSC-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Dimensions Direct-on-line starter MSC-D MSC-D complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MSC-D/BBA complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MSC-DE(A) complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reversing starter MSC-R MSC-R complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MSC-R/BBA complete units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection system SmartWire-DT® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 39 39 40 40 40 41 1 1 1.4 Motor-starter combinations Complete units Ordering 1 MSC-D: PKZM0, DILM Motor data Motor rating I M 3~ Complete units MSC-D Overload trip Part no. Article no. Rated short-circuit current 380 - 415 V 380 - 415 V 380 V 400 V 415 V P 400 V Type “1” coordination Type “2” coordination Ie Iq Iq Ir I rm kW A kA kA A A 0.06 0.21 150 50 0.16 - 0.25 3.5 Short-circuit release 0.09 0.31 150 50 0.25 - 0.4 5.6 0.12 0.18 0.41 0.6 150 50 0.4 - 0.63 0.25 0.8 150 50 0.37 0.55 0.75 1.1 1.5 1.9 150 1.1 1.5 2.2 2.6 3.6 5 3 Price See price list Std. pack I MSC-D-0.25-M7(230V50Hz) 1) 281925 MSC-D-0.4-M7(230V50Hz) 1) 281926 1 off 8.82 MSC-D-0.63-M7(230V50Hz) 1) 281927 1 off 0.63 - 1 14 1 off 50 1 - 1.6 22.4 150 50 1.6 - 2.5 35 MSC-D-1-M7(230V50Hz) 1) 281929 MSC-D-1.6-M7(230V50Hz) 1) 283140 MSC-D-2.5-M7(230V50Hz) 1) 283142 150 50 2.5 - 4 56 1 off 150 50 4 - 6.3 88.2 MSC-D-4-M7(230V50Hz) 1) 283143 MSC-D-6.3-M7(230V50Hz) 1) 283145 6.6 150 – 6.3 - 10 140 1 off 4 8.5 150 – 6.3 - 10 140 MSC-D-10-M7(230V50Hz) 283146 MSC-D-10-M9(230V50Hz) 283147 5.5 11.3 50 – 8 - 12 168 MSC-D-12-M12(230V50Hz) 283148 1 off 7.5 15.2 50 – 10 - 16 224 MSC-D-16-M15(230V50Hz) 100414 1 off 3 4 6.6 8.5 50 50 6.3 - 10 140 MSC-D-10-M17(230V50Hz) 101045 1 off 5.5 11.3 50 50 8 - 12 168 MSC-D-12-M17(230V50Hz) 101046 1 off 7.5 15.2 50 50 10 - 16 224 1 off 11 21.7 50 50 20 - 25 350 MSC-D-16-M17(230V50Hz) 1) 283150 MSC-D-25-M25(230V50Hz) 1) 283151 15 29.3 50 50 25 - 32 448 MSC-D-32-M32(230V50Hz) 1) 283152 1 off I M 3~ 2 Motor starters actuating voltage 230 V 50 Hz Rated operational current AC-3 AC-3 Complete units MSC-D Setting range AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1 off 1 off 1 off 1 off 1 off 1 off Motor-starter combinations Complete units 1.4 1 Motor starters actuating voltage 24 V DC Part no. Article no. Std. pack Motor protective circuit breaker Contactor Price See price list DOL starter wiring set Notes Mechanical connection module and electrical contact module Type Type Type MSC-D-0.25-M7(24VDC)1) 283154 MSC-D-0.4-M7(24VDC)1) 283155 MSC-D-0.63-M7(24VDC)1) 283156 1 off PKZM0-0,25 DILM7-10(...) PKZM0-XDM12 1 off PKZM0-0,4 DILM7-10(...) PKZM0-XDM12 1 off PKZM0-0,63 DILM7-10(...) PKZM0-XDM12 MSC-D-1-M7(24VDC)1) 283158 1 off PKZM0-1 DILM7-10(...) PKZM0-XDM12 MSC-D-1.6-M7(24VDC)1) 283159 MSC-D-2.5-M7(24VDC)1) 283161 1 off PKZM0-1,6 DILM7-10(...) PKZM0-XDM12 1 off PKZM0-2,5 DILM7-10(...) PKZM0-XDM12 MSC-D-4-M7(24VDC)1) 283162 MSC-D-6.3-M7(24VDC)1) 283164 1 off PKZM0-4 DILM7-10(...) PKZM0-XDM12 1 off PKZM0-6,3 DILM7-10(...) PKZM0-XDM12 MSC-D-10-M7(24VDC) 283165 MSC-D-10-M9(24VDC) 283166 1 off PKZM0-10 DILM7-10(...) PKZM0-XDM12 1 off PKZM0-10 DILM9-10(...) PKZM0-XDM12 MSC-D-12-M12(24VDC) 283167 1 off PKZM0-12 DILM12-10(...) PKZM0-XDM12 MSC-D-16-M15(24VDC) 100415 1 off PKZM0-16 DILM15-10(...) PKZM0-XDM12 MSC-D-10-M17(24VDC) 101047 1 off PKZM0-10 DILM17-10(...) PKZM0-XDM32 MSC-D-12-M17(24VDC) 101048 1 off PKZM0-12 DILM17-10(...) PKZM0-XDM32 MSC-D-16-M17(24VDC) 283168 MSC-D-25-M25(24VDC) 283169 1 off PKZM0-16 DILM17-10(...) PKZM0-XDM32 1 off PKZM0-25 DILM25-10(...) PKZM0-XDM32 MSC-D-32-M32(24VDC) 283170 1 off PKZM0-32 DILM32-10(...) PKZM0-XDM32 The DOL starters (complete devices) consist of a motor protective circuit breaker PKZM0 and a contactor DILM. With the adapterless top-hat rail mounting of starters up to 15 A, only the motor-protective circuit-breaker on the top-hat rail requires an adapter. The contactors are provided with mechanical support via a mechanical connection element. Control wire guide with max. 6 conductors with up to 2.5 mm external diameter or 4 conductors up to 3.5 mm external diameter. From 16 A, the motor protective circuit breaker and contactors are mounted on the top-hat rail adapter plate. The connection of the main circuit between PKZ and contactor is established with electrical contact modules. When using auxiliary contacts DILA‐XHIT… J Chapter 1.1 (Page 38) the electrical plugs can be pulled without having to remove the front mounting auxiliary contact. Cannot be combined with NHI-E-...-PKZ0-C standard auxiliary contact with spring-loaded terminal. Further information Technical data PKZM0 Accessories PKZ Technical data DILM Further actuating voltages DILM accessories Page Chapter 1.3 Chapter 1.3 (Page 10) Chapter 1.1 Chapter 1.1 (Page 69) Chapter 1.1 (Page 50) 1) To assemble Type F starters that conform with UL508, incoming terminals BK25/3-PKZ0-E and, if necessary, three-phase terminal blocks B3.../...-PKZ0 can be added to motor starter combinations. Type F starter Page 28 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 3 1.4 Motor-starter combinations Complete units 400/415 V MSC-DE: PKE, DILM 1 Motor data Complete units MSC-US I M 3~ Complete units MSC-US Setting range Rated operational power AC-3 Rated operational current AC-3 Rated shortcircuit current 380 V 400 V 415 V P 400 V 380 - 415 V Ie kW A 0.06 0.21 0.09 Overload trip Shortcircuit release Iq Ir I rm kA A A 100 0.3 - 1.2 16.8 "1" 0.31 100 0.3 - 1.2 16.8 "1" 0.12 0.41 100 0.3 - 1.2 16.8 "1" 0.18 0.6 100 0.3 - 1.2 16.8 "1" 0.25 0.8 100 0.3 - 1.2 16.8 "1" 0.37 1.1 100 0.3 - 1.2 16.8 "1" 0.55 1.5 100 1-4 56 "1" 0.75 1.9 100 1-4 56 "1" 1.1 2.6 100 1-4 56 "1" 1.5 3.6 100 1-4 56 "1" 2.2 5 100 3 - 12 168 "1" 3 6.6 100 3 - 12 168 "1" 4 8.5 100 3 - 12 168 "1" 5.5 11.3 100 3 - 12 168 "1" 2.2 5 100 3 - 12 168 "1", "2" 3 6.6 100 3 - 12 168 "1", "2" 4 8.5 100 3 - 12 168 "1", "2" 5.5 11.3 100 3 - 12 168 7.5 16.7 100 8 - 32 11 21.7 100 15 29.3 100 Std. pack Price See price list I MSC-DE-1.2-M7(230V50Hz) 121735 MSC-DE-1.2-M7(230V50Hz) 121735 MSC-DE-1.2-M7(230V50Hz) 121735 MSC-DE-1.2-M7(230V50Hz) 121735 MSC-DE-1.2-M7(230V50Hz) 121735 MSC-DE-1.2-M7(230V50Hz) 121735 MSC-DE-4-M7(230V50Hz) 121737 1 off MSC-DE-4-M7(230V50Hz) 121737 MSC-DE-4-M7(230V50Hz) 121737 MSC-DE-4-M7(230V50Hz) 121737 1 off MSC-DE-12-M7(230V50Hz) 121739 MSC-DE-12-M7(230V50Hz) 121739 MSC-DE-12-M9(230V50Hz) 121741 1 off MSC-DE-12-M12(230V50Hz) 121743 MSC-DE-12-M17(230V50Hz) 121745 MSC-DE-12-M17(230V50Hz) 121745 MSC-DE-12-M17(230V50Hz) 121745 1 off "1", "2" MSC-DE-12-M17(230V50Hz) 121745 1 off 448 "1", "2" 1 off 8 - 32 448 "1", "2" 8 - 32 448 "1", "2" MSC-DE-32-M17(230V50Hz) 121747 MSC-DE-32-M25(230V50Hz) 121749 MSC-DE-32-M32(230V50Hz) 121751 I M 3~ 4 Type of coordination Motor starters actuating voltage 230 V 50 Hz Part no. Article no. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off Motor-starter combinations Complete units 400/415 V 1.4 1 Motor starters actuating voltage 24 V DC Part no. Article no. Std. pack Motor protective circuit breaker Contactor Price See price list DOL starter wiring set Notes Mechanical connection module and electrical contact module Type Type Type MSC-DE-1.2-M7(24VDC) 121736 MSC-DE-1.2-M7(24VDC) 121736 MSC-DE-1.2-M7(24VDC) 121736 MSC-DE-1.2-M7(24VDC) 121736 MSC-DE-1.2-M7(24VDC) 121736 MSC-DE-1.2-M7(24VDC) 121736 1 off PKE12/XTU-1.2 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTU-1.2 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTU-1.2 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTU-1.2 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTU-1.2 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTU-1.2 DILM7-10(...) PKZM0-XDM12 MSC-DE-4-M7(24VDC) 121738 1 off PKE12/XTU-4 DILM7-10(...) PKZM0-XDM12 MSC-DE-4-M7(24VDC) 121738 MSC-DE-4-M7(24VDC) 121738 MSC-DE-4-M7(24VDC) 121738 1 off PKE12/XTU-4 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTU-4 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTU-4 DILM7-10(...) PKZM0-XDM12 MSC-DE-12-M7(24VDC) 121740 1 off PKE12/XTU-12 DILM7-10(...) PKZM0-XDM12 MSC-DE-12-M7(24VDC) 121740 MSC-DE-12-M9(24VDC) 121742 MSC-DE-12-M12(24VDC) 121744 MSC-DE-12-M17(24VDC) 121746 MSC-DE-12-M17(24VDC) 121746 1 off PKE12/XTU-12 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTU-12 DILM9-10(...) PKZM0-XDM12 1 off PKE12/XTU-12 DILM12-10(...) PKZM0-XDM12 1 off PKE12/XTU-12 DILM17-10(...) PKZM0-XDM32 1 off PKE12/XTU-12 DILM17-10(...) PKZM0-XDM32 MSC-DE-12-M17(24VDC) 121746 MSC-DE-12-M17(24VDC) 121746 1 off PKE12/XTU-12 DILM17-10(...) PKZM0-XDM32 1 off PKE12/XTU-12 DILM17-10(...) PKZM0-XDM32 MSC-DE-32-M17(24VDC) 121748 MSC-DE-32-M25(24VDC) 121750 MSC-DE-32-M32(24VDC) 121752 1 off PKE32/XTU-32 DILM17-10(...) PKZM0-XDM32 1 off PKE32/XTU-32 DILM25-10(...) PKZM0-XDM32 1 off PKE32/XTU-32 DILM32-10(...) PKZM0-XDM32 The DOL starters (complete devices) consist of a PKE motor protective circuit breaker and a DILM contactor. With the adapterless top-hat rail mounting of starters up to 15 A, only the motor protective circuit breaker on the top-hat rail requires an adapter. The contactors are provided with mechanical support via a mechanical connection element. Control wire guide with max. 6 conductors with up to 2.5 mm external diameter or 4 conductors up to 3.5 mm external diameter. From 16 A, the motor protective circuit breaker and contactor are mounted on the top-hat rail adapter plate. The connection of the main circuit between PKE and contactor is established with electrical contact modules. When using auxiliary contacts DILA-XHIT… J Chapter 1.1 (Page 38) the electrical plugs can be pulled without having to remove the front mounting auxiliary contact. Cannot be combined with standard auxiliary contact NHI-E-...-PKZ0-C with spring-loaded terminals. Further information Technical data PKE Accessories PKE Technical data DILM Further actuating voltages DILM accessories Page Chapter 1.3 Chapter 1.3 (Page 10) Chapter 1.1 Chapter 1.1 (Page 69) Chapter 1.1 (Page 50) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 5 1.4 Motor-starter combinations Complete units 400/415 V MSC-DEA: PKE, DILM 1 Motor data Complete devices MSD-DEA I M 3~ Complete devices MSD-DEA Setting range Rated operational power AC-3 Rated operational current AC-3 Rated short-circuit current 380 V 400 V 415 V P 400 V 380 - 415 V Ie Iq Ir I rm kW A kA A A 0.06 0.21 100 0.3 - 1.2 16.8 "1" 0.09 0.31 100 0.3 - 1.2 16.8 "1" 0.12 0.41 100 0.3 - 1.2 16.8 "1" 0.18 0.6 100 0.3 - 1.2 16.8 "1" 0.25 0.8 100 0.3 - 1.2 16.8 "1" 0.37 1.1 100 0.3 - 1.2 16.8 "1" 0.55 1.5 100 1-4 56 "1" 0.75 1.9 100 1-4 56 "1" 1.1 2.6 100 1-4 56 "1" 1.5 3.6 100 1-4 56 "1" 2.2 5 100 3 - 12 168 "1" 3 6.6 100 3 - 12 168 "1" 4 8.5 100 3 - 12 168 "1" 5.5 11.3 100 3 - 12 168 "1" 2.2 5 100 3 - 12 168 "1", "2" 3 6.6 100 3 - 12 168 "1", "2" 4 8.5 100 3 - 12 168 "1", "2" 5.5 11.3 100 3 - 12 168 "1", "2" 7.5 16.7 100 8 - 32 448 "1", "2" 11 21.7 100 8 - 32 448 "1", "2" 15 29.3 100 8 - 32 448 "1", "2" I M 3~ 6 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Overload trip Short-circuit release Type of coordination I Motor-starter combinations Complete units 400/415 V 1.4 1 Motor starters actuating voltage 24 V DC Part no. Article no. Std. pack Motor protective circuit breaker Contactor Price See price list DOL starter wiring set Mechanical connection module and electrical contact module Type Type Type 1 off PKE12/XTUA-1.2 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTUA-1.2 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTUA-1.2 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTUA-1.2 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTUA-1.2 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTUA-1.2 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTUA-4 DILM7-10(...) PKZM0-XDM12 MSC-DEA-4-M7(24VDC) 121754 MSC-DEA-4-M7(24VDC) 121754 MSC-DEA-4-M7(24VDC) 121754 MSC-DEA-12-M7(24VDC) 121755 MSC-DEA-12-M7(24VDC) 121755 1 off PKE12/XTUA-4 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTUA-4 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTUA-4 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTUA-12 DILM7-10(...) PKZM0-XDM12 1 off PKE12/XTUA-12 DILM7-10(...) PKZM0-XDM12 MSC-DEA-12-M9(24VDC) 121756 1 off PKE12/XTUA-12 DILM9-10(...) PKZM0-XDM12 MSC-DEA-12-M12(24VDC) 121757 MSC-DEA-12-M17(24VDC) 121758 MSC-DEA-12-M17(24VDC) 121758 MSC-DEA-12-M17(24VDC) 121758 MSC-DEA-12-M17(24VDC) 121758 1 off PKE12/XTUA-12 DILM12-10(...) PKZM0-XDM12 1 off PKE12/XTUA-12 DILM17-10(...) PKZM0-XDM32 1 off PKE12/XTUA-12 DILM17-10(...) PKZM0-XDM32 1 off PKE12/XTUA-12 DILM17-10(...) PKZM0-XDM32 1 off PKE12/XTUA-12 DILM17-10(...) PKZM0-XDM32 MSC-DEA-32-M17(24VDC) 121759 MSC-DEA-32-M25(24VDC) 121760 MSC-DEA-32-M32(24VDC) 121761 1 off PKE32/XTUA-32 DILM17-10(...) PKZM0-XDM32 1 off PKE32/XTUA-32 DILM25-10(...) PKZM0-XDM32 1 off PKE32/XTUA-32 DILM32-10(...) PKZM0-XDM32 MSC-DEA-1.2-M7(24VDC) 121753 MSC-DEA-1.2-M7(24VDC) 121753 MSC-DEA-1.2-M7(24VDC) 121753 MSC-DEA-1.2-M7(24VDC) 121753 MSC-DEA-1.2-M7(24VDC) 121753 MSC-DEA-1.2-M7(24VDC) 121753 MSC-DEA-4-M7(24VDC) 121754 Notes The DOL starters (complete devices) consist of a PKE motor protective circuit breaker and a DILM contactor. With the adapterless top-hat rail mounting of starters up to 15 A, only the motor protective circuit breaker on the top-hat rail requires an adapter. The contactors are provided with mechanical support via a mechanical connection element. Control wire guide with max. 6 conductors with up to 2.5 mm external diameter or 4 conductors up to 3.5 mm external diameter. From 16 A, the motor protective circuit breaker and contactor are mounted on the top-hat rail adapter plate. The connection of the main circuit between PKE and contactor is established with electrical contact modules. When using auxiliary contacts DILA‐XHIT… J Chapter 1.1 (Page 38) the electrical plugs can be pulled without having to remove the front mounting auxiliary contact. Cannot be combined with standard auxiliary contact NHI-E-...-PKZ0-C with spring-loaded terminals. The DOL starters MSC-DEA... are prepared for communication via SmartWire-DT®. For this the SWD-PKE communication must be added. Further information Technical data PKE Accessories PKE Technical data DILM Further actuating voltages DILM accessories Page Chapter 1.3 Chapter 1.3 (Page 10) Chapter 1.1 Chapter 1.1 (Page 69) Chapter 1.1 (Page 50) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 7 1.4 Motor-starter combinations Modules PKZM, DILM 1 Motor data Modules PKZM0 and DILM Setting range Rated operational power Rated operational current Overload trip Short-circuit release AC-3 AC-3 380 - 415 V 380 - 415 V 380 V 400 V 415 V P 400 V Type “1” coordination Type “2” coordination Ie Iq kW A kA Iq Ir I rm kA A A 0.06 0.09 0.12 0.21 0.31 0.41 150 150 150 50 50 50 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 3.5 5.6 8.82 0.18 0.6 0.25 0.8 150 50 0.4 - 0.63 8.82 150 50 0.63 - 1 0.37 0.55 14 1.1 1.5 150 150 50 50 1 - 1 .6 1 - 1 .6 22.4 22.4 0.75 1.9 150 50 1.6 - 2.5 35 1.1 2.6 150 50 2.5 - 4 56 1.5 3.6 150 50 2.5 - 4 56 2.2 5 150 50 4 - 6.3 88.2 3 4 6.6 8.5 150 150 50 50 6.3 - 10 6.3 - 10 140 140 168 5.5 11.3 50 50 8 - 12 7.5 15.2 50 50 10 - 16 224 11 15 21.7 29.3 50 50 50 50 20 - 25 25 - 32 350 448 5.5 11.3 50 50 10 - 16 224 7.5 15.2 50 50 10 - 16 224 11 21.7 50 50 20 - 25 350 15 29.3 50 50 25 - 32 448 18.5 22 36 41 50 50 50 50 32 - 40 40 - 50 560 700 30 34 55 63 50 50 50 50 50 - 58 55 - 65 812 882 M 3~ Modules PKZM4 and DILM M 3~ 8 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical I Motor-starter combinations Modules 1.4 1 Motor protective circuit breaker Contactor Contactor Type “1” coordination Type “2” coordination Type Type Type PKZM0-0,25 PKZM0-0,4 DILM7-…(…) DILM7-…(…) DILM7-…(…) DILM7-…(…) PKZM0-0,63 DILM7-…(…) DILM7-…(…) PKZM0-0,63 DILM7-…(…) DILM7-…(…) PKZM0-1 DILM7-…(…) DILM7-…(…) PKZM0-1,6 DILM7-…(…) DILM7-…(…) PKZM0-1,6 DILM7-…(…) DILM7-…(…) PKZM0-2,5 PKZM0-4 DILM7-…(…) DILM7-…(…) DILM7-…(…) DILM7-…(…) PKZM0-4 DILM7-…(…) DILM7-…(…) PKZM0-6,3 PKZM0-10 DILM7-…(…) DILM7-…(…) DILM7-…(…) DILM17-…(…) PKZM0-10 DILM9-…(…) DILM17-…(…) PKZM0-12 PKZM0-16 DILM12-…(…) DILM15-…(…) DILM17-…(…) DILM17-…(…) PKZM0-25 PKZM0-32 DILM25-…(…) DILM32-…(…) DILM25-…(…) DILM32-…(…) PKZM4-16 DILM17-…(…) DILM17-…(…) PKZM4-16 DILM17-…(…) DILM17-…(…) PKZM4-25 PKZM4-32 DILM25-…(…) DILM32-…(…) DILM25-…(…) DILM32-…(…) PKZM4-40 DILM40(…) DILM40(…) PKZM4-50 DILM50(…) DILM50(…) PKZM4-58 PKZM4-63 DILM65(…) DILM65(…) DILM65(…) DILM65(…) Notes The motor-starter combinations consist of the motor protective circuit breaker or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102. I q = conditional rated current Further information Technical data PKZM0 Accessories PKZ Technical data DILM Further actuating voltages DILM accessories Page Chapter 1.3 Chapter 1.3 (Page 10) Chapter 1.1 Chapter 1.1 (Page 69) Chapter 1.1 (Page 50) The motor-starter combinations consist of the motor protective circuit breaker or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102. I q = conditional rated current Further information Technical data PKZM4 Accessories PKZ Technical data DILM Further actuating voltages DILM accessories Page Chapter 1.3 Chapter 1.3 (Page 10) Chapter 1.1 Chapter 1.1 (Page 70) Chapter 1.1 (Page 50) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 9 1.4 Motor-starter combinations Modules PKZM, DILM 1 Motor data Modules PKZM0 and DILM M 3~ Modules PKZM4 and DILM Setting range Rated operational power AC-3 Rated operational current AC-3 Rated short-circuit current 500 V 500 V 500 V 500 V Type “1” coordination Type “2” coordination P Ie Iq Iq kW A kA kA 0.06 0.17 100 50 0.16 - 0.25 3.5 0.09 0.25 100 50 0.25 - 0.4 5.6 0.12 0.18 0.33 0.48 100 100 50 50 0.25 - 0.4 0.4 - 0.63 5.6 8.8 0.25 0.7 100 50 0.63 - 1 14 0.37 0.55 0.9 1.2 100 100 50 50 0.63 - 1 1 - 1.6 14 22 Ir A Short-circuit release I rm A 0.75 1.5 100 50 1 - 1.6 22 1.1 1.5 2.1 2.9 100 100 50 50 1.6 - 2.5 2.5 - 4 35 56 2.2 4 42 18 4 - 6.3 88 2.2 4 – 50 4 - 6.3 88 3 5.3 42 18 4 - 6.3 88 3 4 5.3 6.8 – 42 50 18 4 - 6.3 6.3 - 10 88 140 4 5.5 6.8 9 – 42 50 18 6.3 - 10 6.3 - 10 140 140 5.5 6.5 9 10.6 – 42 50 18 6.3 - 10 8 - 12 140 168 6.5 10.6 – 50 8 - 12 168 7.5 7.5 12.1 12.1 15 – 18 50 10 - 16 10 - 16 224 224 11 17.4 6 – 16 - 20 280 11 17.4 15 – 16 - 20 280 15 15 23.4 23.4 6 15 – – 20 - 25 20 - 25 350 350 18.5 28.9 6 – 25 - 32 448 18.5 11 28.9 17.4 15 50 – 50 25 - 32 16 - 25 448 350 15 23.4 50 50 16 - 25 350 18.5 28.9 50 50 25 - 32 448 22 33 50 50 32 - 40 560 30 44 50 50 40 - 50 700 37 45 54 65 50 50 50 50 50 - 58 55 - 65 812 882 M 3~ 10 Overload trip AUTOMATION AND CONTROL www.eaton.com/seasia-electrical I Motor-starter combinations Modules 1.4 1 Motor protective circuit breaker Contactor Contactor Current limiter Type “1” coordination Type “2” coordination Type Type Type Type PKZM0-0,25 PKZM0-0,4 DILM7-…(…) DILM7-…(…) DILM7-…(…) DILM7-…(…) – – PKZM0-0,4 DILM7-…(…) DILM7-…(…) – PKZM0-0,63 PKZM0-1 DILM7-…(…) DILM7-…(…) DILM7-…(…) DILM7-…(…) – – PKZM0-1 DILM7-…(…) DILM7-…(…) – PKZM0-1,6 DILM7-…(…) DILM7-…(…) – PKZM0-1,6 DILM7-…(…) DILM7-…(…) – PKZM0-2,5 PKZM0-4 DILM7-…(…) DILM7-…(…) DILM17-…(…) DILM17-…(…) – – Notes The motor-starter combinations consist of the motor protective circuit breaker or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102. I q = rated conditional short-circuit current. Further information Technical data PKZM... PKZM accessories... Technical data DILM Further actuating voltages DILM accessories PKZM0-6,3 DILM7-…(…) DILM17-…(…) – PKZM0-6,3 – DILM17-…(…) CL-PKZ0 PKZM0-6,3 DILM7-…(…) DILM17-…(…) – PKZM0-6,3 PKZM0-10 – DILM9-…(…) DILM17-…(…) DILM17-…(…) CL-PKZ0 – PKZM0-10 PKZM0-10 – DILM9-…(…) DILM17-…(…) DILM17-…(…) CL-PKZ0 – PKZM0-10 PKZM0-12 – DILM12-…(…) DILM17-…(…) DILM17-…(…) CL-PKZ0 – PKZM0-12 – DILM17-…(…) CL-PKZ0 PKZM0-16 PKZM0-16 DILM17-…(…) – DILM17-…(…) DILM17-…(…) – CL-PKZ0 PKZM0-20 DILM25-…(…) – – PKZM0-20 DILM25-…(…) – CL-PKZ0 PKZM0-25 PKZM0-25 DILM25-…(…) DILM25-…(…) – – – CL-PKZ0 PKZM0-32 DILM32-…(…) – – PKZM0-32 PKZM4-25 DILM32-…(…) DILM40(…) – DILM40(…) CL-PKZ0 – PKZM4-25 DILM40(…) DILM40(…) – PKZM4-32 DILM40(…) DILM40(…) – PKZM4-40 DILM40(…) DILM40(…) – PKZM4-50 DILM50(…) DILM50(…) – PKZM4-58 PKZM4-63 DILM65(…) DILM65(…) DILM65(…) DILM65(…) – – Page Chapter 1.3 Chapter 1.3 (Page 10) Chapter 1.1 Chapter 1.1 (Page 71) Chapter 1.1 (Page 52) The motor-starter combinations consist of the motor protective circuit breaker or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102. I q = rated conditional short-circuit current. Further information Technical data PKZM... PKZM accessories... Technical data DILM Further actuating voltages DILM accessories Page Chapter 1.3 Chapter 1.3 (Page 10) Chapter 1.1 Chapter 1.1 (Page 71) Chapter 1.1 (Page 52) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 11 1.4 Motor-starter combinations Modules NZMN, NZMH, DILM 1 Motor data Modules NZMN and DILM Setting range Rated operational power Rated operational current AC-3 AC-3 380 V 400 V 415 V P 400 V Ie kW A 18.5 22 36 41 30 37 Rated short-circuit current Overload trip Short-circuit release Iq Ir I rm kA A A 50 50 32 - 40 40 - 50 320 - 560 400 - 700 55 50 50 - 63 504 - 882 68 50 63 - 80 640 - 1120 45 81 50 80 - 100 800 - 1250 55 99 50 80 - 100 800 - 1250 75 134 50 125 - 160 1280 - 2240 90 110 161 196 50 50 160 - 200 160 - 200 1600 - 2500 1600 - 2500 132 231 50 175 - 350 350 - 4900 160 279 50 175 - 350 350 - 4900 200 250 349 437 50 50 175 - 350 225 - 450 350 - 4900 450 - 6300 315 544 50 275 - 550 550 - 7700 400 450 683 750 50 50 438 - 875 438 - 875 875 - 12250 875 - 12250 500 560 820 947 50 50 438 - 875 700 - 1400 875 - 12250 1400 -19600 400/415 V I M 3~ Modules NZMH and DILM 22 41 100 40 - 50 400 - 700 30 37 55 68 100 100 50 - 63 63 - 80 504 - 882 640 - 1120 45 81 100 80 - 100 800 - 1250 55 100 100 100 - 125 1000 - 1750 75 134 100 125 - 160 1280 - 2240 30 37 55 68 100 100 45 - 90 45 - 90 90 - 1260 90 - 1260 45 81 100 45 - 90 90 - 1260 55 75 100 134 100 100 70 - 140 70 - 140 140 - 1960 140 - 1960 90 161 100 110 - 120 220 - 3080 110 196 100 110 - 120 220 - 3080 132 231 100 175 - 350 350 - 4900 160 200 279 349 100 100 175 - 350 175 - 350 350 - 4900 350 - 4900 M 3~ 12 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Motor-starter combinations Modules 1.4 1 Notes Circuit-breaker Contactor Contactor Type “1” coordination Type “2” coordination Type Type Type NZMN1-M40 NZMN1-M50 NZMN1-M63 DILM40(…) DILM50(…) DILM65(…) DILM80(…) DILM80(…) DILM80(…) NZMN1-M80 DILM80(…) DILM80(…) NZMN1-M100 DILM95(…) DILM95(…) NZMN1-M100 NZMN2-M160 DILM115(…) DILM150(…) DILM115(…) DILM150(…) NZMN2-M200 DILM185A/22(…) DILM185A/22(…) NZMN2-M200 NZMN3-ME350 DILM225A/22(…) DILM250/22(…) DILM225A/22(…) DILM250/22(…) NZMN3-ME350 DILM300A/22(…) DILM300A/22(…) NZMN3-ME350 DILM400/22(…) DILM400/22(…) NZMN3-ME450 NZMN4-ME550 DILM500/22(…) DILM580/22(…) DILM500/22(…) – NZMN4-ME875 NZMN4-ME875 DILM650/22(…) DILM750/22(…) – – NZMN4-ME875 NZMN4-ME1400 DILM820/22(…) DILM1000/22(…) – – NZMH2-M50 DILM80(…) DILM80(…) NZMH2-M63 DILM80(…) DILM80(…) NZMH2-M80 DILM80(…) DILM80(…) NZMH2-M100 DILM95(…) DILM95(…) NZMH2-M125 DILM115(…) DILM115(…) NZMH2-M160 DILM150(…) DILM150(…) NZMH2-ME90 NZMH2-ME90 DILM80(…) DILM80(…) DILM80(…) DILM80(…) NZMH2-ME90 DILM95(…) DILM95(…) NZMH2-ME140 NZMH2-ME140 DILM115(…) DILM150(…) DILM115(…) DILM150(…) NZMH2-ME220 DILM185A/22(…) DILM185A/22(…) NZMH2-ME220 DILM225A/22(…) DILM225A/22(…) NZMH3-ME350 DILM250/22(…) DILM250/22(…) NZMH3-ME350 NZMH3-ME350 DILM300A/22(…) DILM400/22(…) DILM300A/22(…) DILM400/22(…) The motor-starter combinations consist of the motor protective circuit breaker or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102. I q = conditional rated current The motor-starter combinations consist of the motor protective circuit breaker or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102. I q = conditional rated current AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 13 1.4 Motor-starter combinations Modules 1 Modules NZMH and DILM NZMH, DILM Motor data M 3~ 14 Setting range Rated operational power AC-3 Rated operational current Rated short-circuit current Overload trip Short-circuit release 500 V 525 V P 500 V 525 V 500/525 V Ie Ie kW A A Iq Ir I rm kA A A 11 17.4 17 15 18.5 23.4 28.9 22.5 28 50 16 - 20 350 - 350 50 50 20 - 25 25 - 32 350 - 350 320 - 448 22 30 33 44 32 43 50 50 32 - 40 40 - 50 320 - 560 400 - 700 37 45 54 65 54 64 50 50 50 - 63 63 - 80 504 - 882 640 - 1120 55 79 78 50 63 - 80 640 - 1120 75 107 106 50 100 - 125 1000 - 1750 90 129 127 50 125 - 160 1280 - 2240 30 44 43 50 45 - 90 90 - 1260 37 45 55 54 65 79 54 64 78 50 50 50 45 - 90 45 - 90 45 - 90 90 - 1260 90 - 1260 90 - 1260 75 90 107 129 106 127 50 50 70 - 140 70 - 140 140 - 1960 140 - 1960 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical I Motor-starter combinations Modules 1.4 1 Circuit-breaker Type Contactor Contactor Type “1” coordination Type “2” coordination Type Type NZMH2-M20 DILM40(…) DILM80(…) NZMH2-M25 NZMH2-M32 DILM40(…) DILM40(…) DILM80(…) DILM80(…) NZMH2-M40 NZMH2-M50 DILM40(…) DILM80(…) DILM80(…) DILM80(…) NZMH2-M63 NZMH2-M80 DILM80(…) DILM80(…) DILM80(…) DILM80(…) NZMH2-M80 DILM80(…) DILM80(…) NZMH2-M125 DILM115(…) DILM115(…) NZMH2-M160 DILM150(…) DILM150(…) NZMH2-ME90 DILM80(…) DILM80(…) NZMH2-ME90 NZMH2-ME90 NZMH2-ME90 DILM80(…) DILM80(…) DILM80(…) DILM80(…) DILM80(…) DILM80(…) NZMH2-ME140 NZMH2-ME140 DILM115(…) DILM150(…) DILM115(…) DILM150(…) Notes The motor-starter combinations consist of the motor protective circuit breaker or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102. I q = conditional rated current AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 15 1.4 Motor-starter combinations Modules PKZM0, DILM, ZB; NZMN1, DILM, ZB 1 Motor data Modules PKM0, DILM and ZB with and without automatic reset Setting range Rated operational power AC-3 Rated operational current AC-3 Rated short-circuit current 380 V 400 V 415 V P 400 V 380 - 415 V Ie kW A 0.06 0.09 0.21 0.31 0.12 0.18 0.25 Basic unit Overload trip Short-circuit release Iq Ir I rm kA A A 100 100 0.16 - 0.24 0.24 - 0.4 3.5 5.6 0.41 100 0.4 - 0.6 8.82 PKM0-0,63 0.6 0.8 100 100 0.4 - 0.6 0.6 - 1 8.82 14 PKM0-0,63 PKM0-1 0.37 1.1 100 1 - 1.6 22.4 PKM0-1,6 0.55 0.75 1.5 1.9 100 100 1 - 1.6 1.6 - 2.4 22.4 35 PKM0-1,6 PKM0-2,5 1.1 2.6 100 2.4 - 4 56 PKM0-4 1.5 2.2 3.6 5 100 100 2.4 - 4 4-6 56 88.2 PKM0-4 PKM0-6,3 3 6.6 100 6 - 10 140 PKM0-10 4 8.5 100 6 - 10 140 PKM0-10 5.5 11.3 50 8 - 12 168 PKM0-12 5.5 7.5 11.3 15.2 50 50 10 - 16 10 - 16 168 224 PKM0-12 PKM0-16 11 15 21.7 29.3 50 50 16 - 24 20 - 32 350 448 PKM0-25 PKM0-32 18.5 18.5 36 36 50 50 24 - 40 3 - 65 320 - 560 320 - 560 NZMN1-S40 NZMN1-S40 22 41 50 40 - 57 400 - 700 NZMN1-S50 22 41 50 3 - 65 400 - 700 NZMN1-S50 30 55 50 40 - 57 504 - 882 NZMN1-S63 30 37 55 68 50 50 3 - 65 50 - 70 504 - 882 640 - 1120 NZMN1-S63 NZMN1-S80 37 68 50 10 - 145 640 - 1120 NZMN1-S80 45 45 81 81 50 50 70 - 100 10 - 145 800 - 1250 800 - 1250 NZMN1-S100 NZMN1-S100 55 55 99 99 50 50 70 - 100 10 - 145 800 - 1250 800 - 1250 NZMN1-S100 NZMN1-S100 I Type PKM0-0,25 PKM0-0,4 I> M 3~ Modules NZMN1, DILM and Z... I> M 3~ 16 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Motor-starter combinations Modules 1.4 1 Contactor Overload relay Contactor Overload relay Current sensor Type “1” coordination Type “1” coordination Type “2” coordination Type “2” coordination Type Type Type Type Type DILM7-…(…) DILM7-…(…) ZB12-0,24 ZB12-0,4 DILM7-…(…) DILM7-…(…) ZB12-0,24 ZB12-0,4 – – DILM7-…(…) ZB12-0,6 DILM7-…(…) ZB12-0,6 – DILM7-…(…) DILM7-…(…) ZB12-0,6 ZB12-1 DILM7-…(…) DILM7-…(…) ZB12-0,6 ZB12-1 – – DILM7-…(…) ZB12-1,6 DILM7-…(…) ZB12-1,6 – DILM7-…(…) DILM7-…(…) ZB12-1,6 ZB12-2,4 DILM7-…(…) DILM7-…(…) ZB12-1,6 ZB12-2,4 – – DILM7-…(…) ZB12-4 DILM7-…(…) ZB12-4 – DILM7-…(…) DILM7-…(…) ZB12-4 ZB12-6 DILM7-…(…) DILM17-…(…) ZB12-4 ZB32-6 – – DILM9-…(…) ZB12-10 DILM17-…(…) ZB32-10 – DILM9-…(…) ZB12-10 DILM17-…(…) ZB32-10 – DILM12-…(…) ZB12-12 – – – – DILM17-…(…) – ZB32-16 DILM17-…(…) DILM17-…(…) ZB32-16 ZB32-16 – – DILM25-…(…) DILM32-…(…) ZB32-24 ZB32-32 DILM25-…(…) DILM32-…(…) ZB32-24 ZB32-32 – – DILM40(…) – ZB65-40 – – DILM40(…) DILM50(…) ZB65-57 – – – DILM50(…) DILM65(…) ZB65-57 – – DILM80(…) – ZB150-70 DILM65(…) – – – DILM80(…) DILM95(…) – ZB150-100 – – DILM95(…) DILM115(…) – ZB150-100 – – DILM115(…) Notes The motor-starter combinations consist of the motor protective circuit breaker (without overload function), a contactor and overload relay modules. They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102. I q = conditional rated current The combinations can be operated with or without manual reset. In the Manual position, the combination is blocked against automatic restarting and must be reset locally. In the Auto position, the combination automatically switches on again after the bimetallic elements have cooled down. Further information Technical data PKZMO Accessories PKZ Technical data DILM Further actuating voltages DIL accessories Technical data ZB... Accessories ZB... Page Chapter 1.3 Chapter 1.3 (Page 10) Chapter 1.1 Chapter 1.1 (Page 69) Chapter 1.1 (Page 52) Chapter 1.2 Chapter 1.2 (Page 21) The motor-starter combinations consist of the circuitbreaker (without overload function), contactor and overload relay module. They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102. I q = conditional rated current The combinations can be operated with or without manual reset. In the Manual position, the combination is blocked against automatic restarting and must be reset locally. In the Auto position, the combination automatically switches on again after the bimetallic elements have cooled down. Maximum tripping tolerance CLASS10. Further information Technical data NZMN1 Accessories NZM1 Technical data DILM Further actuating voltages DIL accessories Technical data ZB... Accessories ZB... Page See catalog See catalog Chapter 1.1 Chapter 1.1 (Page 71) Chapter 1.1 (Page 50) Chapter 1.2 Chapter 1.2 (Page 21) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 17 1.4 Motor-starter combinations Complete units MSC-R: PKZM0, DILM 1 Motor data Complete units MSC-R Setting range Rated operational power AC-3 Rated operational current AC-3 380 V 400 V 415 V P 400 V kW Rated short-circuit current Overload trip Shortcircuit releases Motor starters actuating voltage 230 V 50 Hz Part no. Article no. 380 - 415 V 380 - 415 V Ie Type “1” coordination Iq Type “2” coordination Iq Ir I rm A kA kA A A 0.06 0.21 150 50 0.16 - 0.25 3.5 0.09 0.31 150 50 0.25 - 0.4 5.6 0.12 0.18 0.25 0.41 0.6 0.8 150 50 0.4 - 0.63 8.82 150 50 0.63 - 1 14 0.37 0.55 1.1 1.5 150 50 1 - 1.6 22.4 MSC-R-1.6-M7(230V50Hz) 283176 0.75 1.9 150 50 1.6 - 2.5 35 MSC-R-2.5-M7(230V50Hz) 283178 1.1 1.5 2.6 3.6 150 50 2.5 - 4 56 MSC-R-4-M7(230V50Hz) 283179 2.2 5 150 50 4 - 6.3 88.2 MSC-R-6.3-M7(230V50Hz) 283181 3 6.6 150 – 6.3 - 10 140 MSC-R-10-M7(230V50Hz) 283182 4 8.5 150 – 6.3 - 10 140 MSC-R-10-M9(230V50Hz) 283183 5.5 11.3 50 – 8 - 12 168 MSC-R-12-M12(230V50Hz) 283184 3 6.6 50 50 6.3 - 10 140 MSC-R-10-M17(230V50Hz) 101049 4 11.3 50 50 8 - 12 168 7.5 15.2 50 50 10 - 16 224 MSC-R-12-M17(230V50Hz) 101050 MSC-R-16-M17(230V50Hz) 283186 11 21.7 50 50 20 - 25 350 15 29.3 50 50 25 - 32 448 I MSC-R-0.25-M7(230V50Hz) 283171 MSC-R-0.4-M7(230V50Hz) 283172 MSC-R-0.63-M7(230V50Hz) 283173 MSC-R-1-M7(230V50Hz) 283175 M 3~ Complete units MSC-R M 3~ 18 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical MSC-R-25-M25(230V50Hz) 283187 MSC-R-32-M32(230V50Hz) 283188 Price See price list Motor-starter combinations Complete units 1.4 1 Motor starters actuating voltage 24 V DC Part no. Article no. Price See price list Std. pack Motor protective circuit breaker Contactor Reversing starter wiring set Notes Mechanical connection module, electrical contact module and reversing connector Type Type Type MSC-R-0.25-M7(24VDC) 283190 MSC-R-0.4-M7(24VDC) 283191 1 off PKZM0-0,25 DILM7-01(...) PKZM0-XRM12 1 off PKZM0-0,4 DILM7-01(...) PKZM0-XRM12 MSC-R-0.63-M7(24VDC) 283192 1 off PKZM0-0,63 DILM7-01(...) PKZM0-XRM12 MSC-R-1-M7(24VDC) 283194 1 off PKZM0-1 DILM7-01(...) PKZM0-XRM12 MSC-R-1.6-M7(24VDC) 283195 1 off PKZM0-1,6 DILM7-01(...) PKZM0-XRM12 MSC-R-2.5-M7(24VDC) 283197 MSC-R-4-M7(24VDC) 283198 1 off PKZM0-2,5 DILM7-01(...) PKZM0-XRM12 1 off PKZM0-4 DILM7-01(...) PKZM0-XRM12 MSC-R-6.3-M7(24VDC) 283200 1 off PKZM0-6,3 DILM7-01(...) PKZM0-XRM12 MSC-R-10-M7(24VDC) 283201 MSC-R-10-M9(24VDC) 283202 1 off PKZM0-10 DILM7-01(...) PKZM0-XRM12 1 off PKZM0-10 DILM9-01(...) PKZM0-XRM12 MSC-R-12-M12(24VDC) 283203 1 off PKZM0-12 DILM12-01(...) PKZM0-XRM12 MSC-R-10-M17(24VDC) 101051 1 off PKZM0-10 DILM17-01(...) PKZM0-XRM32 MSC-R-12-M17(24VDC) 101052 1 off PKZM0-12 DILM17-01(...) PKZM0-XRM32 MSC-R-16-M17(24VDC) 283204 1 off PKZM0-16 DILM17-01(...) PKZM0-XRM32 MSC-R-25-M25(24VDC) 283205 1 off PKZM0-25 DILM25-01(...) PKZM0-XRM32 MSC-R-32-M32(24VDC) 283206 1 off PKZM0-32 DILM32-01(...) PKZM0-XRM32 The reversing starters (complete devices) consist of a PKZM0 motor protective circuit breaker and two contactors DILM. With the adapterless top-hat rail mounting of starters up to 12 A, only the motor-protective circuit-breaker on the top-hat rail requires an adapter. The contactors are provided with mechanical support via a mechanical connection element. Control wire guide with max. 6 conductors with up to 2.5 mm external diameter or 4 conductors up to 3.5 mm external diameter. From 16 A, the motor protective circuit breaker and contactors are mounted on the top-hat rail adapter plate. The connection of the main circuit between PKZ and contactor is established with electrical contact modules. Complete units with mechanical interlock, starters up to 12 A also with electrical interlock. When using auxiliary contacts DILA‐XHIT… J Chapter 1.1 (Page 38) the electrical plugs can be pulled without having to remove the front mounting auxiliary contact. Cannot be combined with standard auxiliary contact NHI-E-...-PKZ0-C with spring-loaded terminal. Further information Technical data PKZM0 Accessories PKZ Technical data DILM Further actuation voltages DILM accessories Page Chapter 1.3 Chapter 1.3 (Page 10) Chapter 1.1 Chapter 1.1 (Page 69) Chapter 1.1 (Page 50) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 19 1.4 Motor-starter combinations Modules PKZM, DILM 1 Motor data Rated operational power 400 V Modules PKZM0 and DILM Setting range Rated operational current AC-3 Rated short-circuit current Overload trip Short-circuit release 380 - 415 V 380 - 415 V 400 V Type “2” coordination Iq P Ie Type “1” coordination Iq Ir I rm kW A kA kA A A 0.06 0.09 0.21 0.31 150 150 50 50 0.16 - 0.25 0.25 - 0.4 3.5 5.6 0.12 0.18 0.41 0.6 150 150 50 50 0.4 - 0.63 0.4 - 0.63 8.82 8.82 0.25 0.8 150 50 0.63 - 1 14 0.37 1.1 150 50 1 - 1.6 22.4 0.55 0.75 1.5 1.9 150 150 50 50 1 - 1.6 1.6 - 2.5 22.4 35 1.1 2.6 150 50 2.5 - 4 56 1.5 3.6 150 50 2.5 - 4 56 2.2 3 5 6.6 150 150 50 50 4 - 6.3 6.3 - 10 88.2 140 4 5.5 8.5 11.3 150 50 50 50 6.3 - 10 8 - 12 140 168 7.5 15.2 50 50 10 - 16 224 11 15 21.7 29.3 50 50 50 50 20 - 25 25 - 32 350 448 5.5 11.3 50 50 10 - 16 224 7.5 15.2 50 50 10 - 16 224 11 15 21.7 29.3 50 50 50 50 20 - 25 25 - 32 350 448 M 3~ Modules PKZM4 and DILM 18.5 36 50 50 32 - 40 560 22 41 50 50 40 - 50 700 30 55 50 50 50 - 58 812 34 63 50 50 55 - 65 882 M 3~ 20 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical I Motor-starter combinations Modules 1.4 1 Motor protective circuit breaker Type Contactor Contactor Type “1” coordination Type “2” coordination Type Type Notes PKZM0-0,25 PKZM0-0,4 2x 2x DILM7-…(…) DILM7-…(…) 2x 2x DILM7-…(…) DILM7-…(…) PKZM0-0,63 PKZM0-0,63 2x DILM7-…(…) DILM7-…(…) 2x 2x 2x DILM7-…(…) DILM7-…(…) PKZM0-1 2x DILM7-…(…) 2x DILM7-…(…) PKZM0-1,6 2x DILM7-…(…) 2x DILM7-…(…) PKZM0-1,6 PKZM0-2,5 2x DILM7-…(…) DILM7-…(…) 2x 2x 2x DILM7-…(…) DILM7-…(…) PKZM0-4 2x DILM7-…(…) 2x DILM7-…(…) PKZM0-4 2x DILM7-…(…) 2x DILM7-…(…) PKZM0-6,3 PKZM0-10 2x DILM7-…(…) DILM9-…(…) 2x DILM7-…(…) DILM17-…(…) PKZM0-10 PKZM0-12 2x DILM9-…(…) DILM12-…(…) 2x 2x 2x DILM17-…(…) DILM17-…(…) PKZM0-16 2x DILM17-…(…) 2x DILM17-…(…) PKZM0-25 PKZM0-32 2x 2x 2x DILM25-…(…) DILM32-…(…) DILM25-…(…) DILM32-…(…) PKZM4-16 2x DILM17-…(…) 2x DILM17-…(…) PKZM4-16 2x DILM17-…(…) 2x DILM17-…(…) PKZM4-25 PKZM4-32 2x DILM25-…(…) DILM32-…(…) 2x 2x 2x DILM25-…(…) DILM32-…(…) PKZM4-40 2x DILM40(…) 2x DILM40(…) PKZM4-50 2x DILM50(…) 2x DILM50(…) PKZM4-58 2x DILM65(…) 2x DILM65(…) PKZM4-63 2x DILM65(…) 2x DILM65(…) 2x 2x 2x The motor-starter combinations consist of the motor protective circuit breaker or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102. I q = conditional rated current Further information Technical data PKZM0 Accessories PKZ Technical data DILM Other operating voltages DILM accessories Page Chapter 1.3 Chapter 1.3 (Page 10) Chapter 1.1 Chapter 1.1 (Page 69) Chapter 1.1 (Page 50) The motor-starter combinations consist of the motor protective circuit breaker or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102. I q = rated conditional short-circuit current. Further information Technical data PKZM0 Accessories PKZ Technical data DILM Other operating voltages DILM accessories Page Chapter 1.3 Chapter 1.3 (Page 10) Chapter 1.1 Chapter 1.1 (Page 70) Chapter 1.1 (Page 50) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 21 1.4 Motor-starter combinations Modules NZMN, NZMH, DILM 1 Motor data Modules NZMN and DILM Setting range Rated operational power Rated operational current AC-3 AC-3 380 V 400 V 415 V P 400 V Ie kW A 15 18.5 29.3 36 22 30 Rated short-circuit current Overload trip Short-circuit release Iq Ir I rm kA A A 50 50 25 - 32 32 - 40 320 - 448 320 - 560 41 50 40 - 50 400 - 700 55 50 50 - 63 504 - 882 37 68 50 63 - 80 640 - 1120 45 81 50 80 - 100 800 - 1250 55 75 90 99 134 161 50 50 50 80 - 100 125 - 160 160 - 200 800 - 1250 1280 - 2240 1600 - 2500 400/415 V I 110 196 50 160 - 200 1600 - 2500 132 231 50 175 - 350 350 - 4900 160 200 279 349 50 50 175 - 350 175 - 350 350 - 4900 350 - 4900 250 315 437 544 50 50 225 - 450 275 - 550 450 - 6300 550 - 7700 400 683 50 438 - 875 875 - 12250 450 750 50 438 - 875 875 - 12250 500 560 820 947 50 50 438 - 875 700 - 1400 875 - 12250 1400 - 19600 22 30 41 55 100 100 40 - 50 50 - 63 400 - 700 504 - 882 M 3~ Modules NZMH and DILM 37 68 100 63 - 80 640 - 1120 55 55 81 100 100 100 80 - 100 100 - 125 800 - 1250 1000 - 1750 75 134 100 125 - 160 1280 - 2240 30 37 55 68 100 100 45 - 90 45 - 90 90 - 1260 90 - 1260 45 81 100 45 - 90 90 - 1260 55 75 100 134 100 100 70 - 140 70 - 140 140 - 1960 140 - 1960 90 161 100 110 - 120 220 - 3080 110 196 100 110 - 120 220 - 3080 132 231 100 175 - 350 350 - 4900 160 200 279 349 100 100 175 - 350 175 - 350 350 - 4900 350 - 4900 M 3~ 22 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Motor-starter combinations Modules Circuit-breaker Type Contactor Contactor Type “1” coordination Type “2” coordination Type Type 1.4 1 Notes NZMN1-M32 NZMN1-M40 2x 2x DILM40(…) DILM40(…) 2x 2x DILM80(…) DILM80(…) The motor starter combinations consist of the motor protective circuit-breaker and a contactor. They comply with IEC/EN 60947-4-1 and VDE 0660 Part 102. I q = conditional rated current. NZMN1-M50 2x DILM50(…) 2x DILM80(…) NZMN1-M63 2x DILM65(…) 2x DILM80(…) NZMN1-M80 2x DILM80(…) 2x DILM80(…) NZMN1-M100 2x DILM95(…) 2x DILM95(…) NZMN1-M100 NZMN2-M160 NZMN2-M200 2x 2x 2x DILM115(…) DILM150(…) DILM185A/22(…) 2x 2x 2x DILM115(…) DILM150(…) DILM185A/22(…) NZMN2-M200 2x DILM225A/22(…) 2x DILM225A/22(…) NZMN3-ME350 2x DILM250/22(…) 2x DILM250/22(…) NZMN3-ME350 NZMN3-ME350 2x 2x DILM300A/22(…) DILM400/22(…) 2x 2x DILM300A/22(…) DILM400/22(…) NZMN3-ME450 NZMN4-ME550 2x 2x DILM500/22(…) DILM580/22(…) 2x 2x DILM500/22(…) – NZMN4-ME875 2x DILM650/22(…) 2x – NZMN4-ME875 2x DILM750/22(…) 2x – NZMN4-ME875 NZMN4-ME1400 2x 2x DILM820/22(…) DILM1000/22(…) 2x 2x – – NZMH2-M50 NZMH2-M63 2x 2x DILM80(…) DILM80(…) 2x 2x DILM80(…) DILM80(…) NZMH2-M80 2x DILM80(…) 2x DILM80(…) NZMH2-M100 NZMH2-M125 2x 2x DILM95(…) DILM115(…) 2x 2x DILM95(…) DILM115(…) NZMH2-M160 2x DILM150(…) 2x DILM150(…) NZMH2-ME90 NZMH2-ME90 2x 2x DILM80(…) DILM80(…) 2x 2x DILM80(…) DILM80(…) The motor-starter combinations consist of the motor protective circuit breaker or a circuit breaker and a contactor. They conform with IEC/EN 60947-4-1 or VDE 0660 Part 102. I q = rated conditional short-circuit current. NZMH2-ME90 2x DILM95(…) 2x DILM95(…) NZMH2-ME140 NZMH2-ME140 2x 2x DILM115(…) DILM150(…) 2x 2x DILM115(…) DILM150(…) NZMH2-ME220 2x DILM185A/22(…) 2x DILM185A/22(…) NZMH2-ME220 2x DILM225A/22(…) 2x DILM225A/22(…) NZMH3-ME350 2x DILM250/22(…) 2x DILM250/22(…) NZMH3-ME350 NZMH3-ME350 2x 2x DILM300A/22(…) DILM400/22(…) 2x 2x DILM300A/22(…) DILM400/22(…) AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 23 1.4 Motor-starter combinations DOL starters MSC-D.../BBA 1 Motor data Motor rating AC-3 Complete devices PKZ and DIL on BBA Setting range Rated operational current AC-3 Rated short-circuit current 380 - 415 V 380 - 415 V Type “1” coordination Type “2” coordination Overload trip Shortcircuit release 380 V 400 V 415 V P 400 V Ie Iq Iq Ir I rm kW A kA kA A A 0.06 0.21 100 50 0.16 - 0.25 3.5 0.09 0.31 100 50 0.25 - 0.4 5.6 0.12 0.18 0.41 0.6 100 50 0.4 - 0.63 0.25 0.8 100 50 0.37 0.55 1.1 1.5 100 0.75 1.9 1.1 1.5 2.2 Std. pack I 1 off 8.82 MSC-D-0.63-M7(230V50Hz)/BBA 1) 102739 1 off 0.63 - 1 14 1 off 50 1 - 1.6 22.4 MSC-D-1-M7(230V50Hz)/BBA 1) 102950 MSC-D-1.6-M7(230V50Hz)/BBA 1) 102951 100 50 1.6 - 2.5 35 MSC-D-2.5-M7(230V50Hz)/BBA 1) 102952 1 off 2.6 3.6 5 100 50 2.5 - 4 56 1 off 100 50 4 - 6.3 88.2 MSC-D-4-M7(230V50Hz)/BBA 1) 102953 MSC-D-6.3-M7(230V50Hz)/BBA 1) 102954 3 6.6 100 – 6.3 - 10 140 MSC-D-10-M7(230V50Hz)/BBA 102955 1 off 4 8.5 100 – 6.3 - 10 140 1 off 5.5 11.3 100 – 8 - 12 168 MSC-D-10-M9(230V50Hz)/BBA 102956 MSC-D-12-M12(230V50Hz)/BBA 102957 7.5 15.2 50 – 10 - 16 224 MSC-D-16-M15(230V50Hz)/BBA 102958 1 off 3 4 5.5 6.6 8.5 11.3 100 50 6.3 - 10 140 1 off 100 50 8 - 12 168 MSC-D-10-M17(230V50Hz)/BBA 102959 MSC-D-12-M17(230V50Hz)/BBA 102960 7.5 15.2 50 50 10 - 16 224 MSC-D-16-M17(230V50Hz)/BBA 1) 102961 1 off 11 21.7 50 50 20 - 25 350 1 off 15 29.3 50 50 25 - 32 448 MSC-D-25-M25(230V50Hz)/BBA 1) 102962 MSC-D-32-M32(230V50Hz)/BBA 1) 102963 M 3~ I M 3~ 24 Price See price list MSC-D-0.25-M7(230V50Hz)/BBA 1) 102737 MSC-D-0.4-M7(230V50Hz)/BBA 1) 102738 I Complete devices PKZ and DIL on BBA Motor starters actuating voltage 230 V 50 Hz Part no. Article no. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1 off 1 off 1 off 1 off 1 off 1 off 1.4 Motor-starter combinations DOL starters 1 Motor starters actuating voltage 24 V DC Part no. Article no. Price See price list Std. pack Motor protective circuit breaker Contactor DOL starter wiring set Busbar adapter Type Type Type Type Notes Mechanical connection module and electrical contact module MSC-D-0.25-M7(24VDC)/BBA1) 102964 MSC-D-0.4-M7(24VDC)/BBA1) 102965 1 off PKZM0-0,25 DILM7-10(…) PKZM0-XDM12 BBA0-25 1 off PKZM0-0,4 DILM7-10(…) PKZM0-XDM12 BBA0-25 MSC-D-0.63-M7(24VDC)/BBA1) 102966 1 off PKZM0-0,63 DILM7-10(…) PKZM0-XDM12 BBA0-25 MSC-D-1-M7(24VDC)/BBA1) 102967 MSC-D-1.6-M7(24VDC)/BBA1) 102968 1 off PKZM0-1 DILM7-10(…) PKZM0-XDM12 BBA0-25 1 off PKZM0-1,6 DILM7-10(…) PKZM0-XDM12 BBA0-25 MSC-D-2.5-M7(24VDC)/BBA1) 102969 1 off PKZM0-2,5 DILM7-10(…) PKZM0-XDM12 BBA0-25 MSC-D-4-M7(24VDC)/BBA1) 102970 MSC-D-6.3-M7(24VDC)/BBA 102971 1 off PKZM0-4 DILM7-10(…) PKZM0-XDM12 BBA0-25 1 off PKZM0-6,3 DILM7-10(…) PKZM0-XDM12 BBA0-25 MSC-D-10-M7(24VDC)/BBA 102972 1 off PKZM0-10 DILM7-10(…) PKZM0-XDM12 BBA0-25 MSC-D-10-M9(24VDC)/BBA 102973 1 off PKZM0-10 DILM9-10(…) PKZM0-XDM12 BBA0-25 MSC-D-12-M12(24VDC)/BBA 102974 MSC-D-16-M15(24VDC)/BBA 102975 1 off PKZM0-12 DILM12-10(…) PKZM0-XDM12 BBA0-25 1 off PKZM0-16 DILM15-10(…) PKZM0-XDM12 BBA0-25 MSC-D-10-M17(24VDC)/BBA 102976 MSC-D-12-M17(24VDC)/BBA 102977 1 off PKZM0-10 DILM17-10(…) PKZM0-XM32DE BBA0-32 1 off PKZM0-12 DILM17-10(…) PKZM0-XM32DE BBA0-32 MSC-D-16-M17(24VDC)/BBA 102978 1 off PKZM0-16 DILM17-10(…) PKZM0-XM32DE BBA0-32 MSC-D-25-M25(24VDC)/BBA 102979 MSC-D-32-M32(24VDC)/BBA 102980 1 off PKZM0-25 DILM25-10(…) PKZM0-XM32DE BBA0-32 1 off PKZM0-32 DILM32-10(…) PKZM0-XM32DE BBA0-32 The DOL starters (complete devices) consist of a motor protective circuit breaker PKZM0 and a contactor DILM. These combinations are mounted on busbars. The connection of the main circuit between PKZ and contactor is established with electrical contact modules. Cannot be combined with standard auxiliary contact NHI-E-...-PKZ0-C with spring-loaded terminal. Further information Technical data PKZM0 Accessories PKZ Technical data DILM DILM accessories Page Chapter 1.3 Chapter 1.3 (Page 10) Chapter 1.1 Chapter 1.1 (Page 50) 1) To assemble Type F starters that conform with UL508, incoming terminals BK25/3-PKZ0-E and, if necessary, three-phase terminal blocks B3.../...-PKZ0 can be added to motor starter combinations. Type F starter Page 28 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 25 1.4 Motor-starter combinations Reversing starters MSC-R.../BBA 1 Motor starters actuating voltage 230 V 50 Hz Motor data Motor rating Rated short-circuit current 380 - 415 V 380 - 415 V 380 V 400 V 415 V P 400 V Ie Type “1” coordination Iq Type “2” coordination Iq Ir I rm kW A kA kA A A 0.06 0.21 100 50 0.16 - 0.25 3.5 0.09 0.31 100 50 0.25 - 0.4 5.6 0.12 0.18 0.25 0.41 0.6 0.8 100 50 0.4 - 0.63 8.82 100 50 0.63 - 1 14 0.37 0.55 1.1 1.5 100 50 1 - 1.6 22.4 MSC-R-1.6-M7(230V50Hz)/BBA 102985 0.75 1.9 100 50 1.6 - 2.5 35 1.1 1.5 2.6 3.6 100 50 2.5 - 4 56 MSC-R-2.5-M7(230V50Hz)/BBA 102986 MSC-R-4-M7(230V50Hz)/BBA 102987 2.2 5 100 50 4 - 6.3 88.2 MSC-R-6.3-M7(230V50Hz)/BBA 102988 3 6.6 100 – 6.3 - 10 140 MSC-R-10-M7(230V50Hz)/BBA 102989 4 8.5 100 – 6.3 - 10 140 MSC-R-10-M9(230V50Hz)/BBA 102990 5.5 11.3 100 – 8 - 12 168 MSC-R-12-M12(230V50Hz)/BBA 102991 3 4 6.6 8.5 100 50 6.3 - 10 140 MSC-R-10-M17(230V50Hz)/BBA 102992 5.5 11.3 100 50 8 - 12 168 7.5 15.2 50 50 10 - 16 224 MSC-R-12-M17(230V50Hz)/BBA 102993 MSC-R-16-M17(230V50Hz)/BBA 102994 11 21.7 50 50 20 - 25 350 15 29.3 50 50 25 - 32 448 AC-3 Complete devices PKZ and DILM on BBA for reversing starters Setting range Rated operational current AC-3 Overload trip Short-circuit release Part no. Article no. I MSC-R-0.25-M7(230V50Hz)/BBA 102981 MSC-R-0.4-M7(230V50Hz)/BBA 102982 MSC-R-0.63-M7(230V50Hz)/BBA 102983 MSC-R-1-M7(230V50Hz)/BBA 102984 M 3~ Complete devices PKZ and DILM on BBA for reversing starters M 3~ 26 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical MSC-R-25-M25(230V50Hz)/BBA 102995 MSC-R-32-M32(230V50Hz)/BBA 102996 Price See price list Motor-starter combinations Reversing starters 1.4 1 Motor starters actuating voltage 24 V DC Price See price list Std. pack Motor protective circuit breaker Contactor Wiring set Reversing starters Busbar adapter Notes Mechanical connection module, electrical contact module and reversing connector Part no. Article no. Type Type Type Type MSC-R-0.25-M7(24VDC)/BBA 102997 MSC-R-0.4-M7(24VDC)/BBA 102998 1 off PKZM0-0,25 2x DILM7-01(…) PKZM0-XRM12 BBA0R-25 1 off PKZM0-0,4 2x DILM7-01(…) PKZM0-XRM12 BBA0R-25 MSC-R-0.63-M7(24VDC)/BBA 102999 1 off PKZM0-0,63 2x DILM7-01(…) PKZM0-XRM12 BBA0R-25 MSC-R-1-M7(24VDC)/BBA 103000 1 off PKZM0-1 2x DILM7-01(…) PKZM0-XRM12 BBA0R-25 MSC-R-1.6-M7(24VDC)/BBA 103001 MSC-R-2.5-M7(24VDC)/BBA 103002 1 off PKZM0-1,6 2x DILM7-01(…) PKZM0-XRM12 BBA0R-25 1 off PKZM0-2,5 2x DILM7-01(…) PKZM0-XRM12 BBA0R-25 MSC-R-4-M7(24VDC)/BBA 103003 1 off PKZM0-4 2x DILM7-01(…) PKZM0-XRM12 BBA0R-25 MSC-R-6.3-M7(24VDC)/BBA 103004 MSC-R-10-M7(24VDC)/BBA 103005 1 off PKZM0-6,3 2x DILM7-01(…) PKZM0-XRM12 BBA0R-25 1 off PKZM0-10 2x DILM7-01(…) PKZM0-XRM12 BBA0R-25 MSC-R-10-M9(24VDC)/BBA 103006 1 off PKZM0-10 2x DILM9-01(…) PKZM0-XRM12 BBA0R-25 MSC-R-12-M12(24VDC)/BBA 103007 1 off PKZM0-12 2x DILM12-01(…) PKZM0-XRM12 BBA0R-25 MSC-R-10-M17(24VDC)/BBA 103008 1 off PKZM0-10 2x DILM17-01(…) PKZM0-XM32DE + DILM32-XRL BBA0R-32 MSC-R-12-M17(24VDC)/BBA 103009 MSC-R-16-M17(24VDC)/BBA 103010 1 off PKZM0-12 2x DILM17-01(…) BBA0R-32 1 off PKZM0-16 2x DILM17-01(…) PKZM0-XM32DE + DILM32-XRL PKZM0-XM32DE + DILM32-XRL MSC-R-25-M25(24VDC)/BBA 103011 1 off PKZM0-25 2x DILM25-01(…) PKZM0-XM32DE + DILM32-XRL BBA0R-32 MSC-R-32-M32(24VDC)/BBA 103012 1 off PKZM0-32 2x DILM32-01(…) PKZM0-XM32DE + DILM32-XRL BBA0R-32 The reversing starters (complete devices) consist of a PKZM0 motor protective circuit breaker and two contactors DILM. These combinations are mounted on busbars. The connection of the main circuit between PKZ and contactor is established with electrical contact modules. Complete units with mechanical interlock, starters up to 12 A also with electrical interlock. Further information Technical data PKZM0 Accessories PKZ Technical data DILM DILM accessories Page Chapter1.3 Chapter 1.3 (Page 10) Chapter1.1 Chapter 1.1 (Page 50) BBA0R-32 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 27 1.4 Motor-starter combinations Type F starter combinations 1 PKZMO, DILM, BK... Maximum motor rating Setting range Alternating current HP Overload trip 200 V 208 V 230 V 240 V 460 V 480 V 575 V 600 V HP HP HP HP Short-circuit release Ir I rm A A 0.1 - 0.16 0.1 - 0.16 2.2 2.2 I Rated short-circuit breaking capacity I cn 240 V 480 Y 600 Y 277 V 2) 347 V 2) kA kA kA 65 65 65 65 50 50 Extension terminal Motor protective circuit breaker Contactor Type Type Type BK25/3-PKZ0 BK25/3-PKZ0 PKZM0-0,16 PKZM0-0,16 DILEM…(…) DILM7-…(…) Modules PKZM0, DIL, BK 1) ½ ½ 0.16 - 0.25 3.4 65 65 50 BK25/3-PKZ0 PKZM0-0,25 DILEM…(…) 0.16 - 0.25 3.4 65 65 50 BK25/3-PKZ0 PKZM0-0,25 DILM7-…(…) 0.25 - 0.4 0.25 - 0.4 5.6 5.6 65 65 65 65 50 50 BK25/3-PKZ0 BK25/3-PKZ0 PKZM0-0,4 PKZM0-0,4 DILEM…(…) DILM7-…(…) 0.4 - 0.63 8.8 65 65 50 BK25/3-PKZ0 PKZM0-0,63 DILEM…(…) 8.8 14 65 65 65 65 50 50 BK25/3-PKZ0 BK25/3-PKZ0 PKZM0-0,63 PKZM0-1 DILM7-…(…) DILEM…(…) ½ ½ 0.4 - 0.63 0.63 - 1 ½ ½ 0.63 - 1 14 65 65 50 BK25/3-PKZ0 PKZM0-1 DILM7-…(…) ¾ 1 1 - 1.6 22 65 65 50 BK25/3-PKZ0 PKZM0-1,6 DILEM…(…) ¾ 1 1 1½ 1 - 1.6 1.6 - 2.5 22 35 65 65 65 65 50 50 BK25/3-PKZ0 BK25/3-PKZ0 PKZM0-1,6 PKZM0-2,5 DILM7-…(…) DILEM…(…) ½ ½ 1 1½ 1.6 - 2.5 35 65 65 50 BK25/3-PKZ0 PKZM0-2,5 DILM7-…(…) 1 1 1½ 1 1 1½ 2 2 3 3 3 5 2.5 - 4 2.5 - 4 4 - 6.3 56 56 88 65 65 65 65 65 65 50 50 50 BK25/3-PKZ0 BK25/3-PKZ0 BK25/3-PKZ0 PKZM0-4 PKZM0-4 PKZM0-6,3 DILEM…(…) DILM7-…(…) DILEM…(…) 1½ 3 1½ 3 3 7½ 5 10 4 - 6.3 6.3 - 11 88 140 65 65 65 65 50 50 BK25/3-PKZ0 BK25/3-PKZ0 PKZM0-6,3 PKZM0-10 DILM7-…(…) DILM9-…(…) 3 3 7½ – 9 - 12 168 65 65 50 BK25/3-PKZ0 PKZM0-12 DILM12-…(…) 3 3 5 5 10 10 – – 10 - 16 10 - 16 224 224 50 18 50 18 – – BK50/3-PKZ4-E BK50/3-PKZ4-E PKZM0-16 PKZM0-16 DILM17-…(…) DILM17-…(…) 5 5 10 – 16 - 20 280 18 18 – BK50/3-PKZ4-E PKZM0-20 DILM25-…(…) 5 7½ 15 – 20 - 25 350 18 18 – BK50/3-PKZ4-E PKZM0-25 DILM25-…(…) 7½ 10 20 – Modules PKZM4, DIL, BK 25 - 32 448 18 18 – BK50/3-PKZ4-E PKZM0-32 DILM32-…(…) 3 5 10 15 10 - 16 224 65 65 50 BK50/3-PKZ4-E PKZM4-16 DILM17-…(…) 5 7½ 7½ 10 15 25 20 30 16 - 27 24 - 34 350 448 65 65 65 65 50 50 BK50/3-PKZ4-E BK50/3-PKZ4-E PKZM4-25 PKZM4-32 DILM25-…(…) DILM32-…(…) 10 10 15 15 30 30 30 – 32 - 40 40 - 52 560 700 65 65 65 65 50 – BK50/3-PKZ4-E BK50/3-PKZ4-E PKZM4-40 PKZM4-50 DILM40(…) DILM50(…) 15 15 40 – 50 - 56 812 65 65 – BK50/3-PKZ4-E PKZM4-58 DILM65(…) 15 15 40 – 52 - 58 882 65 65 – BK50/3-PKZ4-E PKZM4-63 DILM65(…) Notes 28 Device for world markets IEC UL/CSA Service factor (SF) Set value Ir on the current scale, depending on the load factor SF=1.15 -> Ir = 1 x I n mot SF=1.0 -> Ir = 0.9 x I n mot 1) Calculate motor power in this range according to the rated operational current. Stated values to NEC Table 430 - 150. 2) Suitable for networks with grounded star-point Type F starter combinations do not need an upstream protective device. For use in Canada, the switch must be fitted with an AK-PKZ0. AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.4 Motor-starter combinations Function blocks DILM, ZE, ZB, Z5, ZW7 1 Rating data for approved types1) Max. rated motor current Contactor Overload relay Type Type Maximum motor rating Alternating current HP 200 V 208 V HP 230 V 240 V HP 460 V 480 V HP 575 V 600 V HP Maximum short-circuit protective device for North America Fuse Circuit-breaker 2) CEC or NEC Continuous Short-circuit current release A A A – Modules DIL, Z – – ½ ½ 1 DILEM-…(…) ZE-1.0 3 15 – – ¾ 1 1.4 DILEM-…(…) ZE-1.6 6 15 – ½ ½ 1 1½ 2.3 DILEM-…(…) ZE-2.4 6 15 – – 1 2 3 3.9 DILEM-…(…) ZE-4 15 15 – 1½ – 2 1½ 2 2 3 – 5 – – 5 6 6.8 7.8 DILEM-…(…) DILEM-…(…) DILEM-…(…) ZE-6 ZE-9 ZE-9 20 35 35 15 15 15 – – – 2 – 3 – 5 ½ 5 ½ 9.6 1 DILEM-…(…) DILM7…(…) ZE-12 ZB12-1 45 3 – 25 – 200 – – ¾ 1 1.4 DILM7…(…) ZB12-1,6 6 25 200 ½ 1 ½ 1 1 2 1½ 3 2.3 3.9 DILM7…(…) DILM7…(…) ZB12-2,4 ZB12-4 6 15 25 25 200 200 1½ ½ 3 – 6 DILM7…(…) ZB12-6 20 25 200 – – – 7½ 9 DILM9…(…) ZB12-10 25 25 200 – – 3 – 5 7½ 7½ 10 9.6 11 DILM12…(…) DILM12…(…) ZE-12 ZB12-12 25 45 25 25 200 200 – 5 10 – 15.2 DILM15…(…) ZB12-16 60 40 320 – – ½ – – ½ ½ ¾ 1 ½ 1 1½ 1 1.4 2.3 DILM17…(…) DILM17…(…) DILM17…(…) ZB32-1 278447 ZB32-2,4 3 6 6 25 25 25 200 200 200 1 1 2 3 3.9 DILM17…(…) ZB32-4 15 25 200 ½ 1½ 3 – 6 DILM17…(…) ZB32-6 20 25 200 – 3 5 7½ 9.6 DILM17…(…) ZB32-10 25 25 200 – – – 5 7½ 10 10 – 11 15.2 DILM17…(…) DILM17…(…) ZB32-16 ZB32-16 40 40 30 30 320 320 – – 7½ 10 15 20 20 25 22 32.2 DILM25…(…) DILM32…(…) ZB32-24 ZB32-32 90 125 100 125 1200 1200 – 3 5 7½ 9.6 DILM40(…) ZB65-10 40 40 380 – – 5 7½ 10 20 10 25 15.2 32.2 DILM40(…) DILM40(…) ZB65-16 ZB65-24 60 90 60 90 760 1200 – 10 20 30 34 DILM40(…) ZB65-40 125 125 1200 – 20 40 50 54 DILM50(…) ZB65-57 200 150 2000 – – 20 25 50 50 50 60 63 68 DILM65(…) DILM80(…) ZB65-65 ZB150-70 200 250 160 250 2000 2500 – 30 75 100 99 DILM95(…) ZB150-100 400 400 3200 – 40 100 100 124 DILM115(…) ZB150-125 500 500 4000 – 50 60 60 125 125 125 150 156 156 DILM150(…) DILM185A/22(…) ZB150-150 Z5-160/FF225A 600 600 CLASS J 600 600 4800 7200 60 75 150 200 192 DILM225A/22(…) Z5-220/FF225A 800 CLASS J 800 16000 75 100 100 125 200 250 250 300 248 312 DILM250/22(…) DILM300A/22(…) Z5-250/FF250 ZW7-400 700 CLASS J 1000 600 1000 – – 125 150 300 400 382 DILM400/22(…) ZW7-400 1000 1000 – 150 200 400 500 480 DILM500/22(…) ZW7-540 1000 600 – Notes 1) Devices for world markets IEC UL/CSA 2) Circuit-breaker -> See catalog AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 29 1.4 Motor-starter combinations Function blocks 1 NZMH...-S...-CNA, DILM..., ZB, Z5, ZW7 Rating data for approved types Maximum motor rating Alternating current HP 200 V 208 V 230 V 240 V 460 V 480 V 575 V 600 V HP HP HP HP Setting range Max. rated motor current A Rated short-circuit breaking capacity Overload trip Circuit-breaker Contactor Overload relay Type Type Type Shortcircuit releases 480 V 600 Y 347 V 1) 600 V Ir I rm kA kA kA A A I Minimum enclosure volume cm 3 Module NZMH...-S...-CNA, DILM, Z I> M 3~ – – – – – ½ ½ ¾ 0.9 1.3 100 100 50 50 – – 0.6 - 1 1 - 1.6 12.8 - 22.5 12.8 - 22.5 NZMH2-S1.6-CNA NZMH2-S1.6-CNA DILM17-…(…) DILM17-…(…) ZB32-1 ZB32-1,6 81.5 81.5 – – ¾ – 1.6 100 50 – 1 - 1.6 19.2 - 33.6 NZMH2-S2.4-CNA DILM17-…(…) ZB32-1,6 81.5 – – – ½ 1 – 1 1½ 2.1 2.4 100 100 50 50 – – 1.6 - 2.4 1.6 - 2.4 19.2 - 33.6 32 - 56 NZMH2-S2.4-CNA NZMH2-S5-CNA DILM17-…(…) DILM17-…(…) ZB32-2,4 ZB32-2,4 81.5 81.5 ¾ – 1 ¾ 1 1½ 2 – 3 3 – – 3.9 4.2 6 100 100 100 50 50 50 – – – 2.4 - 4 4-6 4-6 32 - 56 32 - 56 48 - 84 NZMH2-S5-CNA NZMH2-S5-CNA NZMH2-S8-CNA DILM17-…(…) DILM17-…(…) DILM17-…(…) ZB32-4 ZB32-6 ZB32-6 81.5 81.5 81.5 1½ 2 – 5 6.9 100 50 – 6 - 10 48 - 84 NZMH2-S8-CNA DILM17-…(…) ZB32-10 81.5 2 3 5 7½ 9.6 100 50 – 6 - 10 80 - 140 NZMH2-S12-CNA DILM17-…(…) ZB32-10 81.5 3 5 10 10 15.2 100 50 – 10 - 16 128 - 224 NZMH2-S18-CNA DILM17-…(…) ZB32-16 81.5 5 – – 15 17.5 100 50 – 16 - 24 200 - 350 NZMH2-S26-CNA DILM17-…(…) ZB32-24 81.5 – 7½ 15 20 22 100 50 – 16 - 24 200 - 350 NZMH2-S26-CNA DILM25-…(…) ZB32-24 81.5 7½ – – 10 – 20 – 25 25.3 28 100 100 50 50 – – 24 - 32 24 - 32 256 - 448 256 - 448 NZMH2-S33-CNA NZMH2-S33-CNA DILM25-…(…) DILM32-…(…) ZB32-32 ZB32-32 81.5 81.5 10 – – – – 25 – 30 32.2 34 100 100 50 50 – – 24 - 32 32 - 40 320 - 560 320 - 560 NZMH2-S40-CNA NZMH2-S40-CNA DILM32-…(…) DILM40(…) ZB32-32 ZB65-40 81.5 81.5 – – 30 – 40 100 50 – 32 - 40 400 - 700 NZMH2-S50-CNA DILM40(…) ZB65-40 81.5 – 15 – 40 42 100 50 – 40 - 57 400 - 700 NZMH2-S50-CNA DILM40(…) ZB65-57 81.5 15 20 40 50 54 100 50 – 40 - 57 504 - 882 NZMH2-S63-CNA DILM50(…) ZB65-57 81.5 20 – – 25 50 – 60 – 65 68 100 100 50 50 – – 57 - 65 50 - 70 640 - 1120 640 - 1120 NZMH2-S80-CNA NZMH2-S80-CNA DILM65(…) DILM80(…) ZB65-65 ZB150-70 81.5 163 25 30 60 75 80 100 50 – 70 - 100 800 - 1400 NZMH2-S100-CNA DILM80(…) ZB150-100 163 – 30 40 – 75 – 100 – 104 92 100 100 50 50 – – 70 - 100 70 - 100 1000 - 1750 1000 - 1750 NZMH2-S125-CNA NZMH2-S125-CNA DILM95(…) DILM115(…) ZB150-100 ZB150-100 163 163 40 – – 50 100 – 125 – 125 130 100 100 50 50 – – 100 - 125 125 - 150 1280 - 2240 1280 - 2240 NZMH2-S160-CNA NZMH2-S160-CNA DILM115(…) DILM115(…) ZB150-125 ZB150-150 163 163 – – 125 – 156 100 50 – 125 - 150 1600 - 2500 NZMH2-S200-CNA DILM150(…) ZB150-150 265 50 60 – 150 154 100 50 – 120 - 160 1600 - 2500 NZMH2-S200-CNA DILM185/22(…) Z5-160/FF250 265 60 75 75 100 150 200 200 250 192 248 100 100 50 50 – 50 160 - 220 160 - 220 220 - 3080 350 - 4900 NZMH2-SE220-CNA NZMH3-SE350-CNA DILM225/22(…) DILM250/22(…) Z5-220/FF250 Z5-220/FF250 265 306 100 – – 125 – 250 300 – 289 302 100 100 50 50 50 50 190 - 290 270 - 400 350 - 4900 450 - 6300 NZMH3-SE350-CNA NZMH3-SE450-CNA DILM300/22(…) DILM300/22(…) ZW7-290 ZW7-400 306 306 125 150 300 400 382 100 50 50 270 - 400 450 - 6300 NZMH3-SE450-CNA DILM400/22(…) ZW7-400 306 Notes 30 1) Suitable for networks with grounded star-point AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Connection system SmartWire-DT® Function blocks 1.4 Description 1 SWIRE-… 1 2 3 4 5 XI /ON 9 13 9 8 10 7 11 12 1 2 3 4 5 6 7 8 9 10 11 12 Gateway easy NET/CAN open Gateway PROFIBUS-DP Gateway MODBUS Coupling unit XI/ON with SmartWire-DT® Interface card MicroInnovation AG, www.microinnovation.com Interface module B & R CS1011 for X20 system, www.br-automation.com SmartWire-DT® I/O module DOL starter MSC-D up to 32 A DOL starter MSC-D up to 15.5 A SmartWire-DT® power module Connection cable SmartWire-DT® module for DILM Reversing starter MSC-R up to 12 A System description Features With the SmartWire-DT® connection system, switchgear can be connected to a programmable logic controller without the need for complex control wiring. Plug-in SmartWire-DT® cards for DILM and a preassembled connection cable replace the control wiring, dramatically reducing wiring complexity and completely eliminating wiring errors. SmartWire-DT® also cuts the time needed for installation, commissioning and troubleshooting. The PLC’s inputs and outputs are replaced by the SmartWire-DT® module for DILM, and no control wiring terminals are required. Connection to the various fieldbus systems is through third-party gateways or interface modules. • Gateway • Connects the SmartWire-DT® cards with the fieldbus • Supports the fieldbus standards PROFIBUS-DP, MODBUS, CANopen and easy-NET • Supplies the control voltage for the motor starter or contactor • Supplies the supply voltage for the SmartWire-DT® connection system • Configuration button for automatic addressing of the SmartWire-DT® modules for DILM • Supports max. 16 SmartWire-DT® modules for DILM • Interface of third-party manufacturers, e.g. for the XI/ON I/O system, X20 system CS1011 interface module • Connection to the field buses PROFIBUS-DP, MODBUS, CANopen and DeviceNET • SmartWire-DT® module for DILM • Pluggable on contactors • Suitable for contactors DILM7 to DILM32 (24 V DC), DILMC7 to DILMC32 (24 V DC), DILMP20 (24 V DC) or motor starter MSC-... (24 V DC) • Use the standard switchgear of the xStart range • Suitable for DOL and reversing starters • The accessories of the contactor series can be used • Suitable for contactor combinations with PKZ or with Z relays • Integrated switch position monitoring of the contactors • Integrated mechanical switch position display • Actuation of the contactors • Scanning of a potential-free contact, e.g. NHI-E-10-PKZ0 • Electrical interlocking, e.g. possible with reversing starters • LED for status and diagnostic display • Connection to gateway or interface from third party devices • SmartWire-DT® I/O module • 4 digital inputs for connection of potential-free contacts • Power supply for the digital inputs comes from the device • 2 relay outputs 250 V AC • SmartWire-DT® power module • Supply of the 24 V DC control voltage for actuation of contactors DILM • Assembly of Emergency Off groups • Increases the control voltage power in the SmartWire-DT® line • Safety engineering • Emergency switching off disconnection as per IEC/EN 954-1, Switching Category 3 • Central switch off of control voltage at the gateway or SmartWire-DT® power module • Combination with safety-relevant switchgear possible AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 31 1.4 1 Connection system SmartWire-DT® Ordering SWIRE-… Description Part no. Article no. Gateway Gateway with integrated supply for the SmartWire-DT® module and control voltage for the switchgear. - Connection to PROFIBUS-DP as slave. - Transmission rate: 9.6 Kbits/s to 12 MBit/s. - 9 pole SUB-D socket. - Address range 1…126. - Connection to SmartWire-DT® module as master. - Supports 16 SmartWire-DT® modules. PROFIBUS-DP Gateway with integrated supply for the SmartWire-DT® module and control voltage for the switchgear. - Connection to MODBUS-RTU as slave. - Transmission rate: 9.6 to 57.6 Kbits/s. - 9 pole SUB-D socket RS232/RS485. - Address range 1…31. - Connection to SmartWire-DT® module as master. - Supports 16 SmartWire-DT® modules. MODBUS Price See price list Std. pack Notes SWIRE-GW-DP 107027 1 off – SWIRE-GW-MB 118562 1 off – Modules SmartWire-DT® module for DILM SmartWire-DT® module to assemble on the contactors DILM(C)7…DILM(C)38, DILA…, DILMP20 - One module is necessary per contactor. - Connection to SmartWire-DT® gateway as slave. - Max. 16 SmartWire-DT® modules per line. - 1 digital input for floating contact. - Signaling contactor switch position. SWIRE-DIL 107028 5 off • Take account of the max. current consumption of the contactor coils per SmartWire-DT® line. • Length of connection cable at the input and the electrical interlock < 2.8 m. • The A2 connection of the contactors must not be linked. • Electrical interlocking only possible via the terminals on the module for DILM. • Wiring sets DILM 12-XRL and PKZM0XRM12 cannot be used. • Connection terminals for electrical interlocking are not suitable for safety technology. SmartWire-DT® power module Power module for suppling the control voltage. - Connection on SmartWire-DT® gateway as interactive station (no address). SWIRE-PF 107029 1 off Max. 4 power modules per SmartWire-DT® line. SmartWire-DT® I/O mod-ule 4 digital inputs 2 digital relay outputs SWIRE-4DI-2DO-R 107030 1 off Max. 4 SmartWire-DT® I/O modules per line. Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification 32 IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 2252-01 UL Listed, CSA certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1.4 Connection system SmartWire-DT® SWIRE-… 1 Description Part no. Article no. Price See price list Std. pack Notes Cable lengths: Engineering Accessory SmartWire-DT® connection cable 1) Length: 85 mm SWIRE-CAB-008 107032 25 off Length: 110 mm SWIRE-CAB-011 107033 25 off Length: 150 mm SWIRE-CAB-015 107034 5 off Length: 250 mm SWIRE-CAB-025 107035 5 off Length: 500 mm SWIRE-CAB-050 112027 1 off Length: 1000 mm SWIRE-CAB-100 107036 1 off Length: 2000 mm SWIRE-CAB-200 107037 1 off SWIRE-CAB-000 107031 25 off – 6-core, ribbon cable, length: 100 m. SWIRE-CAB-100M 107038 1 off Preassembly of cable only possible with special tool. 6-pin plug for ribbon cable. SWIRE-CAB-CON 107039 50 off For use with SWIRE-CAB-100M. NHI-E-10-PKZ0 with connection cable AWG18 blue, for connection to SmartWire-DT® module for DILM. NHI-E-10L-PKZ0 107040 5 off – DILM12-XR 110099 20 off For use with DILM7…DILM15, without A2 link. Termination connector 1) – Termination plug for last SmartWire-DT® card, 6 pole, no electrical function. Data cable 1) – 34 Plug 1) – NHI-E with cable 1) – Plug-in reversing bridge 2) – For assembling reversing starters with tool-less plug connection Information relevant for export to North America 1) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E29184 NKCR 012528 2252-01 UL Listed, CSA certified 2) Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No.14-05; CE marking E36332 NLRV 012528 3211-05 UL Listed, CSA certified AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 33 1.4 1 Connection system SmartWire-DT® Engineering SWIRE-… Cable lengths For connection between motor starters and contactors DILM, the cable lengths depend on the combination and assembly of the devices. Applications PKZ accessories from to Cable length Contactors DILM None (45 grid) DILM7-…15 DILM17-…38 DILM7-…38 DILM17-…38 DILM7-…15 DILM17-…32 DILM7-…15 DILM17-…32 DILM7-…15 DILM17-…32 DILM7-…15 DILM17-…32 DILM7-…15 DILM17-…32 DILM7-…15 DILM17-…32 DILM7-…15 DILM17-…38 DILM17-…38 DILM7-…15 DILM7-…15 DILM17-…32 DILM17-…32 DILM7-…15 DILM7-…15 DILM17-…32 DILM17-…32 DILM7-…15 DILM7-…15 DILM17-…32 DILM17-…32 DILM7-…15 85 mm 85 mm 110 mm 110 mm 110 mm 110 mm 110 mm 110 mm 85 mm 85 mm 110 mm 110 mm 110 mm 110 mm 150 mm 150 mm PKZM0 with U-/A…/NHI…/AGM… Motor starters MSC None (45 grid) PKZM0 with U-/A…/NHI…/AGM… SWIRE-… Cable lengths The cable lengths for connecting SmartWire-DT® devices depend on the combination and assembly of the devices. Applications Cable length Connection from power module to SWIRE-DIL with mounting beside PKZ Connection from power module to SWIRE-DIL with mounting beside DILM Connection from gateway to SWIRE-DIL with mounting beside PKZ Connection from coupling unit to SWIRE-DIL with mounting beside DILM 250 mm 150 mm 250 mm 250 mm SWIRE-… Magnet systems The number of motor starters or contactors DILM that can be connected is dependant on the power consumption of the magnet systems per SmartWire-DT® line. To increase the number of SmartWire-DT® modules that can be connected, power modules can be used. 24 V DC Pick-up power Holding power 34 W W DILM7 DILM9 DILM12 DILM15 DILM17 DILM25 DILM32/38 3 3 3 3 4.5 4.5 12 at 24 V 0.5 at 24 V 12 at 24 V 0.5 at 24 V 12 at 24 V 0.5 at 24 V 12 at 24 V 0.5 at 24 V AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Connection system SmartWire-DT® 1.4 Technical data 1 SWIRE-… SWIRE-GW-DP General Standards General SWIRE-PF SWIRE-DIL Dimensions (w x d x h) Weight Terminal capacity mm kg IEC/EN 60947 EN 55011 EN 55022 IEC/EN 61000-4 IEC/EN 60068-2-27 IEC 61158 – Top-hat rail IEC/EN 60715 (35mm) or screw fixing with fixing brackets ZB4-101-GF1 (accessories) 35 x 90 x 109 35 x 90 x 74 0.15 0.1 Solid Flexible with ferrule Solid or stranded Flat-blade screwdriver Max. tightening torque Ambient climatic conditions Ambient temperature Operation Storage Condensation Relative humidity, non-condensing (IEC/EN 60068-2-30) Air pressure (in operation) Ambient mechanical conditions Protection type (IEC/EN 60529) Pollution degree Mounting position Electromagnetic compatibility (EMC) Electrostatic discharge (IEC EN 61000-4-2, Level 3, ESD) Air discharge Contact discharge Electromagnetic fields (IEC/EN 61000-4-3, RFI) Radio interference suppression (EN 55011, EN 55022) Burst pulses(IEC/EN 61000-4-4, level 3) Supply cables Signal cables High-energy pulses (surge) (IEC/EN 61000-4-5, level 2) mm² mm² AWG mm Nm 0.34…1.5 0.34…1.5 22…16 3.5 x 0.8 0.6 °C °C -25 - +55 -25 - +55 -25 - +70 -25 - +70 Prevent condensation by means of suitable measures 5 - 95 5 - 95 795 - 1080 795 - 1080 -25 - +60 -25 - +70 IP20 2 Vertical IP20 2 Vertical IP20 2 As per DILM7 to DILM38 8 – 10 8 – 10 8 – 10 Class A Class A Class A kV kV kV 2 2 0.5 (supply cables, symmetrical) 2 2 2 2 V 10 10 10 Profibus-DP Mounting Emitted RFI (IEC/EN 61000-4-6) Insulation resistance % hPa kV kV V/m 0.34…1.5 0.34…1.5 22…16 3.5 x 0.8 0.6 – on DILM7…DILM38 45 x 44 x 81 0.04 0.34…1.5 0.34…1.5 22…16 3.5 x 0.8 0.5 5 - 95 795 - 1080 Clearances and creepage distances EN 50178, EN 60947-1, UL 508, CSA C22.2 No 142 Insulation resistance EN 50178, EN 60947-1 Supply voltage, gateway electronics and SmartWire-DT® station electronics Ugateway Rated operational voltage Ugateway Permissible range V DC 24, -15 %, +20 % 20.4...28.8 – 20.4...28.8 – Supply from gateway or power module Ripple Maximum coupling unit power consumption at 24 V DC % mA – – – – Voltage dips (IEC/EN 61131-2) Heat dissipation at 24 V DC Protection against polarity reversal Short-circuit protection, SmartWire-DT® side ms W ̰5 500 (typically 100 for gateway + typically 25 per SmartWire-DT® module) 10 Normally 6 Yes Yes – Normally 1 – Normally 0.6 – – AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 35 1.4 Connection system SmartWire-DT® SWIRE-… 1 SWIRE-GW-DP SWIRE-PF SWIRE-DIL 24, -15 %, +20 % (Derating from > 40 °C) 20.4…28.8, at 45 °C: 21…28.8, at 50 °C: 21.6…28.8, at 55 °C: 22.2…27.6 Normally 3 Supply from gateway or power module Supply from gateway or power module 10 ̰5 10 – – No, external fuse 3 A or FAZ-Z3 No, external fuse 3 A or FAZ-Z3 – LED indicators Operational Ready: green – Ready: green Power supply, SmartWire-DT® contactors U Aux : green U Aux : green – PROFIBUS-DP status SmartWire-DT® status PROFIBUS-DP: green SmartWire-DT®: green – – – above Ready Output status – – – 1 General Supply voltage UAUX (supply voltage for switching SmartWire-DT® elements, e.g. contactor coils) V DC 24, -15 %, +20 % Rated operational voltage UAUX (Derating from > 40 °C) Permissible range V DC 20.4…28.8, at 45 °C: 21…28.8, at 50 °C: 21.6…28.8, at 55 °C: 22.2…27.6 Input current UAUX at 24 V DC A Normally 3 Ripple % ̰5 Voltage dips (IEC/EN 61131-2) ms Protection against polarity reversal Short-circuit protection, SmartWire-DT® side – Connection floating contacts Number – – V DC – – 17 Input current at “1” signal, typically mA – – 5 Potential isolation Max. cable length m – – – – No < 2.8 Rated voltage (internal supply) Ue PROFIBUS-DP Terminal type SUB-D 9-pole, socket – – Station address 1 … 125 – – Address setting DIP switches – – Potential isolation From UAUX power supply Yes – From UGateway power supply Yes To SmartWire-DT® – Bus protocol Yes PROFIBUS-DP slave PROFIBUS-DP – – Bus Terminating Resistors can be connected via plug – – Baud rate Automatic, up to 12 Mbits/s – – Function SmartWire-DT® Terminal type Plug, 6-pole Plug, 6-pole Plug, 6-pole Data/power cable Maximum cable length, SmartWire-DT® system 6-core ribbon cable Max. 4 6-core ribbon cable Max. 4 6-core ribbon cable Max. 4 m Bus termination No Plug connectors Plug connectors Station address Station Address setting Automatic assignment max. 126 PROFIBUS stations None None Max. 4 SmartWire-DT® cards per line None 1…16 Max. 16 SmartWire-DT® cards per line automatically via SmartWire-DT® Potential isolation From UAUX power supply No No No No No No SmartWire-DT® master no SmartWire-DT® station SmartWire-DT® slave – – – – Normally 20 ms for all stations Normally 10 ms per station From UGateway power supply Function Data transfer time, SmartWire-DT® system Write switch Read status information 36 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Connection system SmartWire-DT® 1.4 SWIRE-… SWIRE-4DI-2DO-R 1 SWIRE-GW-MB General Standards General Dimensions (w x d x h) Weight Terminal capacity Solid mm kg IEC/EN 60947, EN 55011, EN 55022, IEC/EN 61000-4, IEC/EN 60068-2-27 Tophat rail IEC/EN 60715 (35 mm) or screw fixing with fixing brackets ZB4-101-GF1 (accessories) 35 x 90 x 74 35 x 90 x 109 0.12 0.15 mm² 0.5…1.5 0.5…1.5 Flexible with ferrule Solid or stranded mm² AWG 0.5…1.5 22…16 0.5…1.5 22…16 Flat-blade screwdriver Max. tightening torque Ambient climatic conditions Ambient temperature Operation mm Nm 3.5 x 0.8 0.6 3.5 x 0.8 0.6 °C -25 - +55 -25 - +55 °C Mounting Storage Condensation Relative humidity, non-condensing (IEC/EN 60068-2-30) % -25 - +70 -25 - +70 Prevent condensation by means of suitable measures 5 - 95 5 - 95 Air pressure (in operation) hPa 795 - 1080 795 - 1080 IP20 2 Vertical IP20 2 Vertical kV 8 8 kV – 10 Class A – 10 Class A kV kV kV 2 – 0.5 (supply cables, symmetrical) 2 2 V 10 10 Ambient mechanical conditions Protection type (IEC/EN 60529, EN50178, VBG 4) Pollution degree Mounting position Electromagnetic compatibility (EMC) Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD) Air discharge Contact discharge Electromagnetic fields (IEC/EN 61000-4-3, RFI) Radio interference suppression (EN 55011, EN 55022) Burst pulses (IEC/EN 61000-4-4, level 3) Supply cables Signal cables power pulses (surge) (IEC/EN 61000-4-5, level 2) V/m Emitted RFI (IEC/EN 61000-4-6) Insulation resistance Clearances and creepage distances Insulation resistance Supply voltage, gateway electronics and SmartWire-DT® station electronics Ugateway EN 50178, EN 60947-1, UL 508, CSA C22.2 No 142 EN 50178, EN 60947-1 Rated operational voltage Ugateway Permissible range V DC – Supply from gateway or power module 24, -15 %, +20 % 20.4...28.8 Ripple Maximum gateway current consumption at 24 V DC % mA – – Voltage dips (IEC/EN 61131-2) Heat dissipation at 24 V DC Protection against polarity reversal Short-circuit protection, SmartWire-DT® side Power supply UAUX (power supply for switching the SmartWire-DT® slaves, e.g. contactor coils) ms W – – ̰5 500 (normally 100 coupling unit + normally 25 per SmartWire-DT® card) 10 Normally 6 Yes Yes Rated operational voltage U AUX Permissible range V DC V DC – – Input current UAUX at 24 V DC Ripple Voltage dips (IEC/EN 61131-2) Protection against polarity reversal A % ms – – – V – – Voltage Short-circuit protection, SmartWire-DT® side – Us 24, -15 %, +20 % (Derating from > 40 °C) 20.4…28.8, at 45 °C: 21…28.8, at 50 °C: 21.6…28.8, at 55 °C: 22.2…27.6 Normally 3 ̰5 10 Yes Yes No, external 3 A fuse or FAZ-Z3 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 37 1.4 Connection system SmartWire-DT® SWIRE-… 1 SWIRE-4DI-2DO-R SWIRE-GW-MB LED indicators Operational Ready: green Ready: green Power supply, SmartWire-DT® contactors – U Aux : green MODBUS status – MODBUS: yellow SmartWire-DT® status Output status – Q1, Q2: green SmartWire-DT®: green – V DC 4 17 – – mA 5 – Connection floating contacts Number Rated voltage (internal supply) Ue Input current at “1” signal, typically Potential isolation – Yes < 2.8 – Terminal type – SUB-D, 9 pole, socket RS232/RS485 Station address Address setting – – 1 … 31 DIP switches – Yes – Yes Function – – Bus protocol Bus Terminating Resistors Baud rate – – – Yes MODBUS-RTU Slave MODBUS-RTU can be connected via plug Adjustable up to 57.6 (9.6/19.2/38.4) kbit/s Max. cable length MODBUS m Potential isolation From UAUX power supply From UGateway power supply To SmartWire-DT® SmartWire-DT® Terminal type Plug, 6-pole Data/power cable 6-core ribbon cable 6-core ribbon cable Max. 4 Plug connectors Max. 4 No Station address 1…16 Automatic assignment Station Address setting Max. 4 SmartWire-DT® modules per line. Max. 16 automatically via SmartWire-DT® None Maximum cable length, SmartWire-DT® system Bus termination m Plug, 6-pole Potential isolation From UAUX power supply From UGateway power supply Function Data transfer time, SmartWire-DT® system Write switch No No No No SmartWire-DT® slave SmartWire-DT® master Normally 20 ms for all stations – Normally 10 ms per station – V AC 4000 – – Read status information Relay outputs Rated impulse withstand voltage Overvoltage category/pollution degree Rated insulation voltage U imp Ui V III/3 250 Rated operating voltage Making capacity Ue V A 250 30 – – Breaking capacity Rated operational current 380/400 V A 10 – Ie A 3 – Ie I th A A 3 6 – 6 AgG/gL 10 – AC-15, 250 V DC-12, 30 V Conventional thermal current Short-circuit rating without welding max.fuse 38 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Motor-starter combinations DOL starters, reversing starters 1.4 MSC-D, MSC-R, MSC-DE(A) 1 MSC-D, MSC-R, MSC-DE(A) IEC/EN 60947-4-1, VDE 0660 UL 508 (please enquire) CSA C 22.2 No. 14 (please enquire) º 90 Rated impulse withstand voltage Further technical data Overvoltage category/pollution degree Rated operating voltage Motor protective circuit breaker PKZM0, PKE Contactors DILM U imp Ue V AC 6000 V III/3 230 - 415 Chapter 1.3 º º 90 Main contacts 90 Mounting position º Standards 90 General Chapter 1.1 Dimensions DOL starters MSC-D-…-M7[…15]… MSC-D-…-M17[…32]… 67 46 46 67 228 180 180 6 95 45 45 97.4 123.4 MSC-D-…-M7[…15]BBA… MSC-D-…-M17[…32]BBA… 67 95 200 180 60 60 200 180 60 60 40 40 67 45 45 97.4 10 10 35 35 63 63 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 39 1.4 Motor-starter combinations DOL starters, reversing starters Reversing starters MSC-R-…-M7[…12]… MSC-R-…-M17[…32]… 67 46 46 67 114 228 180 180 6 95 90 90 97.4 123.4 MSC-R-…-M7[…12]BBA… MSC-R-…-M17[…32]BBA… 67 60 60 114 180 180 60 60 40 40 67 90 95 90 97.4 10 10 35 35 63 63 DOL starters MSC-DE(A)-...-M7[...12]... MSC-DE(A)-...-M7[...12]... 102 102 97 97 242 196 189 78 50 1 45 45 128 40 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Connection system SmartWire-DT® DOL starters, reversing starters 1.4 Modules SWIRE-DIL 4 38 1 45 50 12 70 SWIRE-PF , SWIRE-4DI-2DO-R 110 90 102 7.5 4.5 66 74 M4 7.5 35.5 Gateways SWIRE-GW-DP..., SWIRE-GW-MB 110 90 4.5 M4 7.5 35.5 102 7.5 105 109 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 41 Control relays XTRG Contents, system overview Control relays XTRG 2.1 Control relays XTRG System overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Basic devices XTRG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3 2 3 4 Control relays XTRG Product description Features System overview Standards and certifications Part of the E Line family of controls, the XTRG control relay offers space savings, enhanced reliability and more efficient use of materials. Rated to operate thermal currents up to 10A, AC voltages up to 660V or DC voltages up to 250V, the XTRG contactor relay offers optimum performance in a compact package. • 10A Control relay • 690V Insulation rating • 660VAC or 250VDC Operational voltage • Up to 5 sets of normally open or normally closed contacts with add-on blocks • All common AC control voltages • DIN rail or panel mount options • Unique 27mm design Control relays are used to remotely switch small loads or in complex control schemes. The XTRG relay can be integrated with contactors from the E Line ramily of motor controls to create compact, efficient control panels for a multitude of applications. • • • • GB 14048 IEC/EN 60947 CCC CE Accessory overview 3 1X 1 1X 2 1 Contactor relay 2 Auxiliary contact modules 3 Surge suppressor AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 2 2.1 XTRG Control relays XTRG Basic devices / Auxiliary contact modules, actuating voltages Control relays Connection type 2 Contact Rated operational current AC-15 Ie (A) N/O=Normally open N/C=Normally closed 220V 230V 240V 380 V 400 V 415 V Conventional Circuit thermal symbol current, open, 40°C Ith (A) Can be combined with auxiliary contact module AC operation Part no. Article no. Standard package Actuating voltage 220V 50HZ Screw terminals 3 N/O - 4 1.9 10 XTCGXFAC10 XTCGXFAC.. XTRG10B30DT 168044 1 piece Screw terminals 2 N/O 1 N/C 4 1.9 10 XTCGXFAC10 XTCGXFAC.. XTRG10B21DT 167927 1 piece Screw terminals 1 N/O 2 N/C 4 1.9 10 XTCGXFAC10 XTCGXFAC.. XTRG10B12DT 167968 1 piece Screw terminals - 3 N/C 4 1.9 10 XTCGXFAC10 XTCGXFAC.. XTRG10B03DT 167978 1 piece Alternate actuating voltages Coil Voltage 3NO 2NO/ 1NC 1NO/ 2NC 3NC 24VAC 50Hz XTRG10B30B5 168040 XTRG10B21B5 167923 XTRG10B12B5 167933 36VAC 50Hz XTRG10B30DS 168041 XTRG10B21DS 167924 XTRG10B12DS 167934 XTRG10B03B5 167974 XTRG10B03DS 167975 48VAC 50Hz XTRG10B30C5 168042 XTRG10B30E5 168043 XTRG10B21C5 167925 XTRG10B21E5 167926 XTRG10B12C5 167966 XTRG10B12E5 167967 XTRG10B03C5 167976 XTRG10B03E5 167977 XTRG10B30DT 168044 XTRG10B30DU 168047 XTRG10B21DT 167927 XTRG10B21DU 167930 XTRG10B12DT 167968 XTRG10B12DU 167971 XTRG10B03DT 167978 XTRG10B03DU 167936 110VAC 50Hz 220VAC 50Hz 380VAC 50Hz Auxiliary contact, top mounting Auxiliary contact modules Connection type Conventional thermal current open, 40°C Contact Circuit symbol N/O=Normally open N/C=Normal closed Can be combined with control relay Part no. Article no. Standard package XTCGXFAC10 167939 XTCGXFAC01 167940 1 piece XTCGXFAC20 167941 XTCGXFAC11 167942 1 piece XTCGXFAC02 167943 1 piece Ith = Ie AC-1 A Screw terminals 1 pole 10 1 N/O - XTRG10B.. Screw terminals 1 pole 10 - 1 N/C XTRG10B.. Screw terminals 2 pole 10 2 N/O - XTRG10B.. Screw terminals 2 pole 10 1 N/O 1 N/C XTRG10B.. Screw terminals 2 pole 10 - 2 N/C XTRG10B.. Coil surge supressor Coil voltage RC Varistor 24-48V XTCGXRSCN2 167946 XTCGXRSCDV 167947 XTCGXVSCN2 167949 XTCGXVSCDV 167950 XTCGXRSCCM 167948 XTCGXVSCCM 167951 110-220V 380-440V 3 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1 piece 1 piece Control relays XTRG Technical data 2.1 General XTRG10B.. XTCGXFAC.. 2 IEC/EN 60947, GB 14048 Standards Mechanical lifespan AC operated Operations Maximum operating frequency Maximum operating frequency Climatic proofing x 106 Operations/h 10 10 600 600 Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Operation Storage °C °C Protection type Weight approximate weight kg -5~40 -25~55 IP20 0.17 -5~40 -25~55 IP20 0.02 XTRG10B.. XTCGXFAC.. VAC 6000 6000 Ui VAC III/3 690 III/3 690 Ue VAC 660 660 Ie A 6 6 Ie Ie Ie Ie Ie A A A A A 4 1.9 1.5 1.4 1.2 4 1.9 Ie Ie Ith A A A 0.55 0.27 10 0.55 0.27 10 Operations x 106 1 1 Contacts Rated impulse withstand voltage Overvoltage category/degree of pollution Rated insulation voltage Rated operational voltage Rated operational current AC-15 120V 240V 380V 480V 500V 600V DC-13 125V 250V Conventional thermal current Electrical lifespan at Ue=230V, AC-15, 3A Uimp Magnet system XTRG10B.. Voltage tolerance AC operated Power consumption Pick-up Pick-up Sealing Sealing x Uc VA VA W 0.85-1.1 30 6 2 Terminals XTRG10B.. XTCGXFAC.. mm2 mm2 Nm mm2 Nm 0.75-2.5 0.75-2.5 0.8 0.75-2.5 0.8 0.75-2.5 0.75-2.5 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 4 2.1 Contactors XTCG Contents Contactors XTCG System overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contactors Basic devices XTCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical data Contactors XTCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary contact modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contactors XTCG 2 Contactors XTCG Product description Features System overview Standards and certifications The XTCG is the flagship of the E Line family of motor controls. The XTCG contactor offers space savings, enhanced reliability and more efficient use of materials. Boasting AC-3 ratings up to 32A @ 400V and with a maximum operating voltage of 660V, XTCG offers tremendous performance in a small package. • Technologically advanced contact design • 690V insulation rating • Operating voltage up to 660VAC • Up to (3) add on auxiliary contact modules • All common AC control voltages • DIN rail or panel mount options • Unique space saving design 3 phase contactors are used to start motors or control industrial loads. The E Line family of contactors allows the starting of motors up to 15kW, and when combined with an XTOD overload relay or PKZC motor protective circuit breaker offers a complete package of protection and control for long life and reliable operation. • • • • GB 14048 IEC/EN 60947 CCC CE Accessory overview 7-12A Frame 18-32A Frame 3 1X 3 1X 18-32A Frame with mechanical interlock 1 4 1 1X 2 5 1X 2 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1 2 3 4 Contactor relay Auxiliary contact modules Surge suppressor Interlocking kit 5 6 6 6 7 7 2.1 Contactors XTCG Basic devices / Auxiliary contact modules, actuating voltages / Accessories XTCG 3-pole contactors Conventional thermal current, open, 40 °C Ith = Ie AC-1(A) Connection type Rated operational current AC-3 Ie (A) 380V Screw terminals 7 2.2 3 3.5 20 Screw terminals 9 2.5 4 4.5 20 Screw terminals Screw terminals Screw terminals Screw terminals 12 3.5 5.5 5.5 20 18 5 7.5 7.5 25 25 7.5 11 11 35 32 10 15 15 40 Max motor rating for 3-phase motors, 50-60Hz AC-3 P kW 220V 380V 660V Circuit symbol AC operation Part no. Article no. Actuating voltage 220V 50Hz 2 XTCG007B00DT 167984 XTCG009B00DT 167994 XTCG012B00DT 168004 XTCG018C00DT 168014 XTCG025C00DT 168024 XTCG032C00DT 168034 Standard package: 1piece Alternate actuating voltages Coil voltage 7A 9A 12A 18A 25A 32A 24VAC 50Hz XTCG007B00B5 167980 XTCG007B00DS 167981 XTCG009B00B5 167990 XTCG009B00DS 167991 XTCG012B00B5 168000 XTCG012B00DS 168001 XTCG018C00B5 168010 XTCG018C00DS 168011 XTCG025C00B5 168020 XTCG025C00DS 168021 XTCG032C00B5 168030 XTCG032C00DS 168031 XTCG007B00C5 167982 XTCG007B00E5 167983 XTCG007B00DT 167984 XTCG007B00DU 167987 XTCG009B00C5 167992 XTCG009B00E5 167993 XTCG009B00DT 167994 XTCG009B00DU 167997 XTCG012B00C5 168002 XTCG012B00E5 168003 XTCG012B00DT 168004 XTCG012B00DU 168007 XTCG018C00C5 168012 XTCG018C00E5 168013 XTCG018C00DT 168014 XTCG018C00DU 168017 XTCG025C00C5 168022 XTCG025C00E5 168023 XTCG025C00DT 168024 XTCG025C00DU 168027 XTCG032C00C5 168032 XTCG032C00E5 168033 XTCG032C00DT 168034 XTCG032C00DU 168037 Can be combined with control relay Part no. Article no. Standard package 36VAC 50Hz 48VAC 50Hz 110VAC 50Hz 220VAC 50Hz 380VAC 50Hz Auxiliary contact, top mounting Auxiliary contact modules Conventional thermal current open, 40°C Connection type Contact Circuit symbol N/O=Normally open N/C=Normal closed Ith = Ie AC-1 A Screw terminals 1 pole 10 1 N/O - XTCG10B... XTCGXFAC10 167939 1 piece Screw terminals 1 pole 10 - 1 N/C XTCG10B... XTCGXFAC01 167940 1 piece Screw terminals 2 pole 10 2 N/O - XTCG10B... 1 piece Screw terminals 2 pole 10 1 N/O 1 N/C XTCG10B... XTCGXFAC20 167941 XTCGXFAC11 167942 Screw terminals 2 pole 10 - 2 N/C XTCG10B... XTCGXFAC02 167943 1 piece 1 piece Mechanical interlock Coil surge supressor Coil voltage RC Varistor 7-12A 18-32A 24-48V XTCGXRSCN2 167946 XTCGXVSCN2 167949 XTCGXMLB 167944 XTCGXMLC 167945 110-220V XTCGXRSCDV 167947 XTCGXVSCDV 167950 380-440V XTCGXRSCCM 167948 XTCGXVSCCM 167951 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 6 2.1 Contactors XTCG Technical data General XT Basic device CG007 CG012 CG018 CG025 CG032 10 10 10 10 600 600 600 Damp heat,constant,to IEC60068-2-78 Damp heat,cyclic,to IEC60068-2-30 600 600 600 -5~40 -25~55 IP20 0.17 -5~40 -25~55 IP20 0.17 -5~40 -25~55 IP20 0.17 -5~40 -25~55 IP20 0.35 -5~40 -25~55 IP20 0.35 -5~40 -25~55 IP20 0.35 0.75-2.5 M3.5 0.8 M3.5 0.8 0.75-2.5 M3.5 0.8 M3.5 0.8 0.75-2.5 M3.5 0.8 M3.5 0.8 0.75-2.5 M5 2 M3.5 0.8 0.75-2.5 M5 2 M3.5 0.8 0.75-2.5 M5 2 M3.5 0.8 V AC V AC A 6000 III/3 690 660 70 6000 III/3 690 660 90 6000 III/3 690 660 120 6000 III/3 690 660 180 6000 III/3 690 660 250 6000 III/3 690 660 320 A 56 72 96 144 200 256 Op. 1,500,000 1,500,000 1,500,000 1,000,000 1,000,000 1,000,000 Op. 100,000 100,000 100,000 100,000 100,000 100,000 Pick-up x Uc 0.85-1.1 0.85-1.1 0.85-1.1 0.85-1.1 0.85-1.1 0.85-1.1 Pick-up Sealing Sealing VA VA W 30 6 2 30 6 2 30 6 2 80 8.1 2.4 80 8.1 2.4 80 8.1 2.4 Standards 2 Lifespan, mechanical AC operated Operations Operating frequency Operations/h AC operated Climatic Proofing x 106 Ambient temperature Operation Storage Protection type Weight Terminal capacity of main cable Nm Nm 380V Electrical lifespan AC-3 Power consumption of coil in a cold state and 1.0 xUc kg mm2 Main contacts Uimp Rated impulse withstand voltage Overvoltage category / pollution degree Rated insulation voltage Ui Rated operational voltage Ue Making capacity 380V (cos ij to IEC/EN60947) AC-4 Magnet systems Voltage tolerance AC operated °C °C 10 10 AWG Solid/stranded Terminal capacity of control circuit cable Main cable connection screws / bolts Tightening torque Control circuit cable connection screws / bolts Tightening torque Breaking capacity (cos ij to IEC/EN60947) CG009 IEC/EN 60947, GB 14048 V AC Terminals Auxiliary contact XTCGXFAC.. Uimp Rated impulse withstand voltage Overvoltage category/degree of pollution Ui Rated insulation voltage Ue Rated operational voltage Rated operational current VAC VAC VAC 7-12A 6000 III/3 690 660 mm2 AC-15 120V 240V 380V Ie Ie Ie A A A 6 4 1.9 Ie Ie Ith A A A 0.55 0.27 10 x 106 1 mm2 0.75-2.5 0.75-2.5 0.75-2.5 0.75-2.5 Nm 0.8 Aux Contact mm2 0.75-2.5 Nm 0.8 18-32A DC-13 125V 250V Conventional thermal current Electrical lifespan at Ue=230V, AC-15, 3A 7 Operations AUTOMATION AND CONTROL www.eaton.com/seasia-electrical mm2 mm2 1-6 (1 - 10)* 1-6 (1 - 10)* 1-4 (1 - 10)* 1-4 (1 - 10)* Nm 2 Aux Contact mm2 0.75-2.5 Nm 0.8 Dimensions 2.1 Contactors 18-32A Frame 7-12A Frame 2 3hĭ4 3hĭ4 113 82 97.5 35.3 77.5 35.3 70.1 Auxiliary contact module 1 Pole 2 Pole Thermal overload relay + mounting adapter XTOD..CC1S AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 8 2.1 Dimensions Control Relay 2 Surge suppressor 3 × ĭ4 Mechanical interlock 7-12A Frame 18-32A Frame 9 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 2.2 Thermal overload relays XTOD Contents Thermal overload relays XTOD 2 Thermal overload relays XTOD System overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Thermal overload relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Thermal overload relays XTOD Product description Features System overview Standards and certifications XTOD thermal overload relays offer precision motor protection with phase loss protection and ambient temperature compensation. The seperate mount design allows for flexibility and the units can be mounted on DIN rail or directly on the panel adjacent the motor contactor. • Precision motor protection up to 32A • Integral 1NO/1NC contact for contactor control and alarm signal • Phase loss protection • Ambient temperature compensation • DIN rail or panel mount options Thermal overload relays provide protective features for 1 or 3 phase motors. The relay monitors the operating current of the motor and switched the contactor off in the event of an overload situation. It also protects the motor from damage during phase loss. • • • • 2 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical GB 14048 IEC/EN 60947 CCC CE 2 3 3 5 Thermal overload relays XTOD Thermal overload relays 2.2 Thermal overload relays For use with XTOD..CC1S XTCG007 XTCG009 XTCG012 XTCG018 XTCG025 XTCG032 Setting range of overload releases Ir (A) Seperate mounting Circuit symbol Seperate mounting Seperate mounting 97 95 0.3~0.45 2 4 6 2 4 6 Seperate mounting Seperate mounting Seperate mounting 4 6 4 6 4 6 4 6 4 6 2 4 6 2 4 6 2 4 6 2 4 6 1 N/C 1 N/O 1 N/C 1 N/O 1 N/C 1 N/O 1 N/C 1 N/O 1 N/C 1 N/O 1 N/C 1 N/O 1 N/C 1 N/O 1 N/C 1 N/O 1 N/C 98 96 98 96 97 95 22~30 1 N/O 98 96 97 95 17~24 1 N/C 98 96 97 95 12.5~18 1 N/O 98 96 97 95 8.5~12.5 1 N/C 98 96 97 95 5.5~8.5 1 N/O 98 96 97 95 4.0~6.0 1 N/C 98 96 97 95 3.5~5.0 1 N/O 98 96 97 95 2.4~3.6 1 N/C 98 96 97 95 2 Seperate mounting 6 1.8~2.7 2 Seperate mounting 4 1 N/O 98 96 97 95 2 Seperate mounting 6 1.4 ~2.1 2 Seperate mounting 4 1 N/C 98 96 97 95 1.0 ~1.5 1 N/O 98 96 97 95 0.67~1.0 2 Seperate mounting 6 0.45 ~0.67 2 Seperate mounting 4 97 95 2 Seperate mounting Part no. Article no. Standard package XTODP45CC1S 167952 XTODP67CC1S 167953 XTOD001CC1S 167954 XTOD1P5CC1S 167955 XTOD2P2CC1S 167956 XTOD2P7CC1S 167957 XTOD3P6CC1S 167958 XTOD005CC1S 167959 XTOD006CC1S 167960 XTOD8P5CC1S 167961 XTOD013CC1S 167962 XTOD018CC1S 167963 XTOD024CC1S 167964 XTOD030CC1S 167965 1 piece 2 N/O =Normally open N/C =Normally closed 2 Seperate mounting Auxiliary contact 98 96 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 3 2.2 Thermal overload relays XTOD Technical data General XTOD..CC1S 2 Standards IEC/EN 60947, GB 14048 Damp heat, constant, to IEC60068-2-78 Damp heat, cyclic, to IEC60068-2-30 Climatic Proofing Ambient temperature Open Enclosed Temperature compensation Weight Protection type °C -25~55 °C °C kg -25~40 -5~40 0.15 IP20 Main contacts XTOD..CC1S Rated impulse withstand voltage Overvoltage category/pollution degree Rated insulation voltage AC Rated operational voltage Overload release setting range Terminal capacity Solid Uimp VAC 6000 III/3 Ui Ue VAC VAC A 690 600 0.3-30 mm2 1 x (1-6) 2 x (1-6) Flexible with ferrule mm2 1 x (1-6) 2 x (1-6) Solid/stranded Terminal screw Tightening torque AWG Nm M4 1.2 Auxiliary and control circuits XTOD..CC1S Rated impulse withstand voltage Overvoltage category/pollution degree Uimp V 6000 III/3 Terminal capacity Solid mm2 1 x (1-6) 2 x (1-6) Flexible with ferrule mm2 1 x (1-6) 2 x (1-6) Solid/stranded Terminal screw Tightening torque Rated insulation voltage Rated operational voltage AWG Conventional thermal current Rated operational current AC-15 120V 220/240V 380V 480V 500V 600V DC-13 125V 250V 4 Ui Ue Nm VAC VAC M3.5 0.8 690 600 Ith A 10 Ie Ie Ie Ie Ie Ie A A A A A A 6 3 1.9 1.5 1.4 1.2 Ie Ie A A 0.55 0.27 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical Thermal overload relays XTOD Dimensions 2.2 Dimensions Thermal overload relay + mounting adapter XTOD..CC1S 2 AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 5
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2013:06:27 12:27:32+08:00 Modify Date : 2013:06:27 13:28:48+08:00 Metadata Date : 2013:06:27 13:28:48+08:00 Document ID : uuid:6D1F8ECDE1DEE21199E597DDE4498DA5 Instance ID : uuid:b95adc77-214d-447f-9988-5f7e3484bf68 Derived From Instance ID : uuid:4294c9b0-518f-4dc8-95d2-0b7cda0e333c Derived From Document ID : uuid:0c7f1211-f782-4fe6-a4cd-74cfa23098db Format : application/pdf Title : xStart-1-1.eps Creator : Administrator Page Count : 309 Author : AdministratorEXIF Metadata provided by EXIF.tools