ENGLISH
Non contact Voltage (NcV): > 25V Ac

8.

Ac current Measurement

SYMBOLS uSED ON LcD

~
O.L.
MIN

Ac Measurement

Dc Measurement

Negative Dc Value

AT

Overload: Range Exceeded

Apo Auto power-Off Active

Low Battery

HOLD

Minimum Reading

MAX Maximum Reading

Auto Range Active

Hold Active

%

Duty cycle Mode

V

Voltage Measurement

Ω

Resistance in Ohms

Diode test

F

capacitance in Farads

continuity test

Frequency Mode

A

current in Amps

Range

Resolution

Accuracy

600µA

0.1µA

± (2.0% + 5 digits)

2000µA

1µA

± (1.5% + 5 digits)

60A

0.01A

± (2.9% + 15 digits)

600A ~ 1000A

0.1A ~ 1A

± (1.9% + 8 digits)

Overload protection:
• Voltage: 600V RMS
• current: 2000µA (leads), 1000A (clamp)
Frequency: 45 to 400Hz
Minimum current for Frequency Measurement: 400µA (leads) or 20A (clamp)
Response: True RMS

Range

Resolution

Accuracy

600Ω ˜ 6MΩ

0.1Ω ˜ 0.001MΩ

± (1.0% + 4 digits)

60MΩ

0.01MΩ

± (2.0% + 4 digits)




caution: This symbol indicates that equipment and its accessories

shall be subject to a separate collection and correct disposal.

Resolution

Accuracy

60nF ˜ 6000µF

0.01nF ˜ 1µF

± (3.5% + 6 digits)

Micro 10

m

Milli 10

Frequency Measurement

k

Kilo 103

M

Mega 106

Range

Resolution

Accuracy

99.99Hz ˜ 499.9kHz

0.01Hz ˜ 100Hz

± (0.1% + 4 digits)

• BAcKLIGHt
• WORKLIGHt

Duty cycle Measurement
Accuracy

Range

Resolution

Accuracy

600mV ˜ 600V

0.1mV ˜ 0.1V

± (0.5% + 4 digits)

0.1 ˜ 99.9%

0.1%

± (0.2% per kHz + 0.1% + 5 digits)

1000V

1V

± (0.8% + 10 digits)

750V
1000V
1000A

Overload protection: 600V RMS
Diode test

Range

Resolution

Accuracy

600mV ˜ 750V

0.1mV ˜ 1V

± (2.0% + 5 digits)

Overload protection: 750V RMS
Frequency Response: 45 to 400 Hz
Minimum Voltage for Frequency Measurement: 200mV
Response: True RMS
Dc current Measurement
Range

Resolution

Accuracy

600µA

0.1µA

2000µA

1µA

60A

0.01A

± (2.5% + 15 digits)

600A ~ 1000A

0.1A ~ 1A

± (1.5% + 8 digits)

± (1.2% + 3 digits)

Overload protection:
• Voltage: 600V RMS
• current: 2000µA (leads), 1000A (clamp)

• AutO / MANuAL
RANGE

• ANALOG BAR GRApH

Overload protection: 600V RMS

Resolution

Ac Voltage Measurement

• tRuE RMS

• 3-5/6 DIGIt
5999 cOuNt LcD

Range

Overload protection: 1000V

• 1000A Ac/Dc

• MAX / MIN / HOLD

Range

µ

Dc Voltage Measurement

ENGLISH

• NON cONtAct
VOLtAGE tEStER

capacitance Measurement

Overload protection: 600V RMS

ELEctRIcAL SpEcIFIcAtIONS

StORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.

Overload protection: 600V RMS

Nano 10

-3

Instruction Manual

cLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.

DISpOSAL / REcYcLE

n

-6

www.kleintools.com/warranty

Resistance Measurement

Relative / Zero Mode

-9

CL2500

WARRANtY

Overload protection

Range

test current

Open circuit Voltage

600V RMS

6.0V

Appx. 0.25mA

< 1.8V DC

continuity test
Overload protection

Open circuit Voltage

threshold (Appx.)

600V RMS

< 0.44V

~40Ω

Non contact Voltage Detector
On Voltage
Appx. 25V AC and above

cuStOMER SERVIcE
KLEIN tOOLS, INc.

450 Bond Street
Lincolnshire, IL 60069
www.kleintools.com
139677 Rev. 11/13 B

CL2500 Instruction Manuals - MASTER.indd 1-4

11/20/2013 2:57:08 PM

Dwg Name: CL2500-139677ART Dwg No: 139677
ECO No: 14678 Pkg Dwg Ref: 1650 Rev: B
Color Reference: CEN-PACK-003-A

ENGLISH

CL2500
Instruction Manual

H. I.	 Battery Replacement
•	 When
indicator is displayed on the LCD, batteries must be
replaced.
•	 Remove the back screw and replace 2 x AAA batteries.
J.	 Magnetic Back
•	 Attach instrument to metal for hands-free use.

Feature Details

General Specifications
The Klein Tools CL2500 is a True RMS, auto-ranging clamp meter. It measures
AC / DC voltage, AC / DC current, resistance, capacitance, frequency, and duty
cycle. It can also test non-contact voltage, diodes, and continuity.
•	 Operating Altitude: 2000 meters
•	 Storage Altitude: 10000 meters
•	 Humidity: 0% to 80% at 32°F to 95°F (0°C to 35°C)
0% to 70% at 32°F to 131°F (0°C to 55°C)
•	 Operating Temperature: 0°C / 32°F to 40°C / 104°F < 75% R.H.
•	 Storage Temperature: -20°C / -4°F to 60°C / 140°F
•	 Accuracy Temperature: 18°C / 64°F to 28°C / 82°F
•	 Temperature Coefficient: 0.1*(specified accuracy) / °C
•	 Dimensions: 8.09" x 2.56" x 1.38" (205 mm x 65 mm x 35 mm)
•	 Weight: 14 oz. (400 g)
•	 Calibration: Accurate for one year
•	 Certifications: UL & cUL standard UL3111-1 Listed
•	 Pollution Degree: 2
•	 Accuracy: ± (% of reading + # of least significant digits)
•	 Ingress Protection: IP42
•	 Drop Protection: 1 m (3 ft.)
•	 Safety Rating: CATIII 1000V, CAT IV 600V

WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
•	 Before each use, verify meter operation by measuring
a known voltage or current.
•	 Never use the meter on a circuit with voltages that exceed the
category based rating of this meter.
•	 Do not use the meter during electrical storms, or in wet weather.
•	 Do not use the meter or test leads if they appear to be damaged.
•	 Ensure meter leads are fully seated, and keep fingers away from
the metal probe contacts when making measurements.
•	 Do not open meter to replace batteries while probes are connected.
•	 Use caution when working with voltages above 60V DC,
or 25V AC RMS. Such voltages pose a shock hazard.
•	 To avoid false readings that can lead to electrical shock,
replace batteries if a low battery indicator appears.
•	 Unless measuring voltage or current, shut off and lock out
power before measuring resistance or capacitance.
•	 Always adhere to local and national safety codes. Use individual
protective equipment to prevent shock and arc blast injury where
hazardous live conductors are exposed.

SYMBOLS

~

AC Alternating Current

Warning or Caution

DC Direct Current

Dangerous levels

DC/AC Voltage or Current

Double Insulated Class II

Ground

Safe for disconnect
from live conductors

AC Source

K.	

1

B
8

E

Frequency (Hz) / Duty Cycle (See FEATURE DETAILS)
Features: HOLD

Bar Graph
•	 The bar graph shows an approximate analog representation
of a measurement.
•	 The bar graph responds much faster than the digital display.
•	 The scale of the bar graph is zero to the maximum reading of
the selected range.

•	 Select

,

, or

setting.

5.	Resistance: < 60MΩ

Function Instructions

Features: HOLD RANGE

MAX/MIN

1
2

J

F

6

G
D 4
H
C

4.	

7
I
4
K
A

A.	Use CAT IV 600 rated leads or higher.
Do not attempt to measure more than 1000V DC or 750V AC or 2000µA.
B.	 Keep hands below line when measuring high current levels.
C.	 Auto Power-Off (Apo)
•	 Device will power off after 30 minutes non-use.
•	 Turn the dial or press a button to wake.
•	 Disabled during Max / Min function.
•	 Holding Select button while turning on disables Auto Power-Off.
D.	 Select Functionality Button
•	 Quick press (<0.5 sec):
»» Switch between AC and DC.
»» Switch between
and .
•	 Long press (>1 sec):
»» Switch between AC, Frequency, and Duty Cycle modes.
»» Zero the DC current clamp reading.
E.	 Hold / Backlight / Worklight
•	 Press to hold the current input on the display.
•	 Press again to return to live reading.
•	 Press for 2 seconds to enable / disable lights.
•	 Using lights decreases battery life.
F.	
Auto / Manual Range
•	 Press repeatedly to cycle through manual ranges.
•	 Press for 2 seconds to return to auto ranging mode.
•	 AT is displayed on LCD only during auto ranging mode.
G.	 Max / Min Hold
•	 Press to enter Max / Min mode; the largest and smallest
values will be saved while in this mode.
•	 Press repeatedly to alternate between the maximum and minimum readings.
•	 Press for 2 seconds to return to live reading and clear
the stored maximum and minimum values.

•	

5

6.	Capacitance: < 6000µF

3
1.	

Do not measure resistance on a live circuit.

Features: HOLD

AC / DC Current (large): < 1000A
Features: HOLD RANGE

MAX/MIN

ZERO (DC)

•	
Safely discharge capacitor before measurement.
•	 Reading may take up to 60 seconds for large capacitors.
•	 Center wire in guides for best accuracy.
•	 Opposing currents cancel. Use line-splitter (USA only) when necessary.
2.	

7.	

Diode / Continuity

AC / DC Current (small): < 2000µA
Features: HOLD RANGE

MAX/MIN

PRESIONE

Diode Features:
HOLD

•	 Select AC or DC current source.
Current above 2000µA will damage instrument.
•	
3.	

Diodo

AC / DC Voltage: < 750V AC or 1000V DC
Features: HOLD RANGE

MAX/MIN

MAX/MIN

Display shows:

PRESIONE

Continuidad

•	 Forward voltage drop if forward biased.
•	 “O.L.” if reverse biased.
Continuity Features:
HOLD

MAX/MIN

•	 Display shows resistance.
•	 Buzzer sounds if less than 40Ω.
Diodo

Continuidad

•	 Select AC or DC voltage source.

CL2500 Instruction Manuals - MASTER.indd 5-8

11/20/2013 2:57:11 PM

Dwg Name: CL2500-139677ART Dwg No: 139677
ECO No: 14678 Pkg Dwg Ref: 1650 Rev: B
Color Reference: CEN-PACK-003-A



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Create Date                     : 2013:11:20 14:57:05-06:00
Metadata Date                   : 2014:01:02 15:19:24-06:00
Modify Date                     : 2014:01:02 15:19:24-06:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:e6392c25-08db-4521-ad54-f12eaa4063e5
Original Document ID            : xmp.did:FB7F117407206811AB08D11C1C1ABC37
Document ID                     : xmp.id:B8D0294A2652E311A8EA90322AC27364
Rendition Class                 : proof:pdf
Version ID                      : 1
Derived From Instance ID        : xmp.iid:B7D0294A2652E311A8EA90322AC27364
Derived From Document ID        : xmp.did:39EA6E8F1938E311A2E1D7B6333E5EFF
Derived From Original Document ID: xmp.did:FB7F117407206811AB08D11C1C1ABC37
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2013:11:20 14:57:05-06:00
Format                          : application/pdf
Title                           : CL2500 Instruction Manuals - MASTER.indd
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
GTS PDFX Version                : PDF/X-1:2001
GTS PDFX Conformance            : PDF/X-1a:2001
Page Layout                     : SinglePage
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu