CL2500 Instruction Manuals MASTER Installation Directions
2014-07-05
: Pdf 622636-Installationsheet 622636-InstallationSheet 092644 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
ENGLISH Non contact Voltage (NcV): > 25V Ac 8. Ac current Measurement SYMBOLS uSED ON LcD ~ O.L. MIN Ac Measurement Dc Measurement Negative Dc Value AT Overload: Range Exceeded Apo Auto power-Off Active Low Battery HOLD Minimum Reading MAX Maximum Reading Auto Range Active Hold Active % Duty cycle Mode V Voltage Measurement Ω Resistance in Ohms Diode test F capacitance in Farads continuity test Frequency Mode A current in Amps Range Resolution Accuracy 600µA 0.1µA ± (2.0% + 5 digits) 2000µA 1µA ± (1.5% + 5 digits) 60A 0.01A ± (2.9% + 15 digits) 600A ~ 1000A 0.1A ~ 1A ± (1.9% + 8 digits) Overload protection: • Voltage: 600V RMS • current: 2000µA (leads), 1000A (clamp) Frequency: 45 to 400Hz Minimum current for Frequency Measurement: 400µA (leads) or 20A (clamp) Response: True RMS Range Resolution Accuracy 600Ω ˜ 6MΩ 0.1Ω ˜ 0.001MΩ ± (1.0% + 4 digits) 60MΩ 0.01MΩ ± (2.0% + 4 digits) caution: This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal. Resolution Accuracy 60nF ˜ 6000µF 0.01nF ˜ 1µF ± (3.5% + 6 digits) Micro 10 m Milli 10 Frequency Measurement k Kilo 103 M Mega 106 Range Resolution Accuracy 99.99Hz ˜ 499.9kHz 0.01Hz ˜ 100Hz ± (0.1% + 4 digits) • BAcKLIGHt • WORKLIGHt Duty cycle Measurement Accuracy Range Resolution Accuracy 600mV ˜ 600V 0.1mV ˜ 0.1V ± (0.5% + 4 digits) 0.1 ˜ 99.9% 0.1% ± (0.2% per kHz + 0.1% + 5 digits) 1000V 1V ± (0.8% + 10 digits) 750V 1000V 1000A Overload protection: 600V RMS Diode test Range Resolution Accuracy 600mV ˜ 750V 0.1mV ˜ 1V ± (2.0% + 5 digits) Overload protection: 750V RMS Frequency Response: 45 to 400 Hz Minimum Voltage for Frequency Measurement: 200mV Response: True RMS Dc current Measurement Range Resolution Accuracy 600µA 0.1µA 2000µA 1µA 60A 0.01A ± (2.5% + 15 digits) 600A ~ 1000A 0.1A ~ 1A ± (1.5% + 8 digits) ± (1.2% + 3 digits) Overload protection: • Voltage: 600V RMS • current: 2000µA (leads), 1000A (clamp) • AutO / MANuAL RANGE • ANALOG BAR GRApH Overload protection: 600V RMS Resolution Ac Voltage Measurement • tRuE RMS • 3-5/6 DIGIt 5999 cOuNt LcD Range Overload protection: 1000V • 1000A Ac/Dc • MAX / MIN / HOLD Range µ Dc Voltage Measurement ENGLISH • NON cONtAct VOLtAGE tEStER capacitance Measurement Overload protection: 600V RMS ELEctRIcAL SpEcIFIcAtIONS StORAGE Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the Specifications section, allow the instrument to return to normal operating conditions before using it. Overload protection: 600V RMS Nano 10 -3 Instruction Manual cLEANING Turn instrument off and disconnect test leads. Clean the instrument by using a damp cloth. Do not use abrasive cleaners or solvents. DISpOSAL / REcYcLE n -6 www.kleintools.com/warranty Resistance Measurement Relative / Zero Mode -9 CL2500 WARRANtY Overload protection Range test current Open circuit Voltage 600V RMS 6.0V Appx. 0.25mA < 1.8V DC continuity test Overload protection Open circuit Voltage threshold (Appx.) 600V RMS < 0.44V ~40Ω Non contact Voltage Detector On Voltage Appx. 25V AC and above cuStOMER SERVIcE KLEIN tOOLS, INc. 450 Bond Street Lincolnshire, IL 60069 www.kleintools.com 139677 Rev. 11/13 B CL2500 Instruction Manuals - MASTER.indd 1-4 11/20/2013 2:57:08 PM Dwg Name: CL2500-139677ART Dwg No: 139677 ECO No: 14678 Pkg Dwg Ref: 1650 Rev: B Color Reference: CEN-PACK-003-A ENGLISH CL2500 Instruction Manual H. I. Battery Replacement • When indicator is displayed on the LCD, batteries must be replaced. • Remove the back screw and replace 2 x AAA batteries. J. Magnetic Back • Attach instrument to metal for hands-free use. Feature Details General Specifications The Klein Tools CL2500 is a True RMS, auto-ranging clamp meter. It measures AC / DC voltage, AC / DC current, resistance, capacitance, frequency, and duty cycle. It can also test non-contact voltage, diodes, and continuity. • Operating Altitude: 2000 meters • Storage Altitude: 10000 meters • Humidity: 0% to 80% at 32°F to 95°F (0°C to 35°C) 0% to 70% at 32°F to 131°F (0°C to 55°C) • Operating Temperature: 0°C / 32°F to 40°C / 104°F < 75% R.H. • Storage Temperature: -20°C / -4°F to 60°C / 140°F • Accuracy Temperature: 18°C / 64°F to 28°C / 82°F • Temperature Coefficient: 0.1*(specified accuracy) / °C • Dimensions: 8.09" x 2.56" x 1.38" (205 mm x 65 mm x 35 mm) • Weight: 14 oz. (400 g) • Calibration: Accurate for one year • Certifications: UL & cUL standard UL3111-1 Listed • Pollution Degree: 2 • Accuracy: ± (% of reading + # of least significant digits) • Ingress Protection: IP42 • Drop Protection: 1 m (3 ft.) • Safety Rating: CATIII 1000V, CAT IV 600V WARNINGS To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can result in severe injury or death. • Before each use, verify meter operation by measuring a known voltage or current. • Never use the meter on a circuit with voltages that exceed the category based rating of this meter. • Do not use the meter during electrical storms, or in wet weather. • Do not use the meter or test leads if they appear to be damaged. • Ensure meter leads are fully seated, and keep fingers away from the metal probe contacts when making measurements. • Do not open meter to replace batteries while probes are connected. • Use caution when working with voltages above 60V DC, or 25V AC RMS. Such voltages pose a shock hazard. • To avoid false readings that can lead to electrical shock, replace batteries if a low battery indicator appears. • Unless measuring voltage or current, shut off and lock out power before measuring resistance or capacitance. • Always adhere to local and national safety codes. Use individual protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed. SYMBOLS ~ AC Alternating Current Warning or Caution DC Direct Current Dangerous levels DC/AC Voltage or Current Double Insulated Class II Ground Safe for disconnect from live conductors AC Source K. 1 B 8 E Frequency (Hz) / Duty Cycle (See FEATURE DETAILS) Features: HOLD Bar Graph • The bar graph shows an approximate analog representation of a measurement. • The bar graph responds much faster than the digital display. • The scale of the bar graph is zero to the maximum reading of the selected range. • Select , , or setting. 5. Resistance: < 60MΩ Function Instructions Features: HOLD RANGE MAX/MIN 1 2 J F 6 G D 4 H C 4. 7 I 4 K A A. Use CAT IV 600 rated leads or higher. Do not attempt to measure more than 1000V DC or 750V AC or 2000µA. B. Keep hands below line when measuring high current levels. C. Auto Power-Off (Apo) • Device will power off after 30 minutes non-use. • Turn the dial or press a button to wake. • Disabled during Max / Min function. • Holding Select button while turning on disables Auto Power-Off. D. Select Functionality Button • Quick press (<0.5 sec): »» Switch between AC and DC. »» Switch between and . • Long press (>1 sec): »» Switch between AC, Frequency, and Duty Cycle modes. »» Zero the DC current clamp reading. E. Hold / Backlight / Worklight • Press to hold the current input on the display. • Press again to return to live reading. • Press for 2 seconds to enable / disable lights. • Using lights decreases battery life. F. Auto / Manual Range • Press repeatedly to cycle through manual ranges. • Press for 2 seconds to return to auto ranging mode. • AT is displayed on LCD only during auto ranging mode. G. Max / Min Hold • Press to enter Max / Min mode; the largest and smallest values will be saved while in this mode. • Press repeatedly to alternate between the maximum and minimum readings. • Press for 2 seconds to return to live reading and clear the stored maximum and minimum values. • 5 6. Capacitance: < 6000µF 3 1. Do not measure resistance on a live circuit. Features: HOLD AC / DC Current (large): < 1000A Features: HOLD RANGE MAX/MIN ZERO (DC) • Safely discharge capacitor before measurement. • Reading may take up to 60 seconds for large capacitors. • Center wire in guides for best accuracy. • Opposing currents cancel. Use line-splitter (USA only) when necessary. 2. 7. Diode / Continuity AC / DC Current (small): < 2000µA Features: HOLD RANGE MAX/MIN PRESIONE Diode Features: HOLD • Select AC or DC current source. Current above 2000µA will damage instrument. • 3. Diodo AC / DC Voltage: < 750V AC or 1000V DC Features: HOLD RANGE MAX/MIN MAX/MIN Display shows: PRESIONE Continuidad • Forward voltage drop if forward biased. • “O.L.” if reverse biased. Continuity Features: HOLD MAX/MIN • Display shows resistance. • Buzzer sounds if less than 40Ω. Diodo Continuidad • Select AC or DC voltage source. CL2500 Instruction Manuals - MASTER.indd 5-8 11/20/2013 2:57:11 PM Dwg Name: CL2500-139677ART Dwg No: 139677 ECO No: 14678 Pkg Dwg Ref: 1650 Rev: B Color Reference: CEN-PACK-003-A
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Create Date : 2013:11:20 14:57:05-06:00 Metadata Date : 2014:01:02 15:19:24-06:00 Modify Date : 2014:01:02 15:19:24-06:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:e6392c25-08db-4521-ad54-f12eaa4063e5 Original Document ID : xmp.did:FB7F117407206811AB08D11C1C1ABC37 Document ID : xmp.id:B8D0294A2652E311A8EA90322AC27364 Rendition Class : proof:pdf Version ID : 1 Derived From Instance ID : xmp.iid:B7D0294A2652E311A8EA90322AC27364 Derived From Document ID : xmp.did:39EA6E8F1938E311A2E1D7B6333E5EFF Derived From Original Document ID: xmp.did:FB7F117407206811AB08D11C1C1ABC37 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2013:11:20 14:57:05-06:00 Format : application/pdf Title : CL2500 Instruction Manuals - MASTER.indd Producer : Adobe PDF Library 10.0.1 Trapped : False GTS PDFX Version : PDF/X-1:2001 GTS PDFX Conformance : PDF/X-1a:2001 Page Layout : SinglePage Page Count : 2 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools