METALUX
WaveStream Luminaire Installation Instruction Sheet
Fixture Installation/Wiring
1.	Remove product from packaging material. Carton should be lying down flat, oriented 		
	with THIS SIDE UP markings facing up so that top panel of carton can be folded back 		
	 and fixture can be lifted straight up out of packaging materials. Do not lift fixture 		
	 by one end or pull on the end plates in any way. Luminaire should be handled by both 		
	 aluminum side rails. Wear clean work gloves to prevent dirt and oil from being 			
	 transferred to luminaire.

	

Figure A.
Plastic Insert

2.	Note that the protective plastic insert that is shipped in the luminaire is 		
	 intended to stay in the luminaire for protection of the lenses (Figure A).		
	 Take caution when handling the luminaire to not scratch or damage the 		
	 lenses in the fixture.

	

3.	Install the luminaire into the ceiling T-grid system. Ensure that luminaire sets 		
	 snuggly in T-grid system (Figure B). Ensure that all luminaires in an area are 		
	 oriented in the same direction.

	

4.	When required, attach EQ Clips to luminaire end plate with supplied screws to 		
	 secure luminaire to T-grid system (Figure C). Take care to not over torque and 	
	 strip screws.

	
Figure B.
Install in Ceiling T-Grid System

5.	Remove electrical access plate and remove necessary knockouts from access 	
	 plate for attachment of electrical supply cable (Figure D). For questions about 		
	 proper wiring of fixtures, see Metalux website.

	

6.	Make necessary wiring connections to driver AC line input and optional DALI or 0-10V 		
	 dimming circuits.
7.	Replace electrical access plate and snap securely into place. If required, install optional 	
	 screw to lock the access plate closed.
Final Luminaire Prep
The luminaire is shipped with a protective plastic
insert that is intended to stay in the luminaire during
building construction to keep dust and dirt from
accumulating on the luminaire. Once all building
construction and cleanup is complete, the insert is
to be removed and recycled (Figure E).
Fixture Maintenance/Cleaning

Figure C.
EQ Clip Installed

ATTENTION
Figure E.
Removed Plastic Insert

Always follow recommended cleaning and handling procedures when cleaning
the WaveStreamTM lens. It can be permanently damaged if cleaned or handled
improperly.
Before cleaning a WaveStreamTM lens, take time to inspect the surfaces carefully
in order to determine the type and severity of the contaminants. The process of
cleaning the lens can result in damage to the optical surface if repeated multiple
times.
For WaveStreamTM lens with multiple contaminants, the order with which they are
removed can be important. For instance, if a WaveStreamTM lens is contaminated
with oil and dust, it is possible that wiping the oil off first will scratch the optical
surface as the dust is drug along the surface by the wipe.

Standard Access Plate
Installation
Grounding conductor
(if insulated) to be
stripped min. 1".
Insert end of wire
into small hole. Wrap wire
under and around head of screw
counter-clockwise (as illustrated).
Tighten screw.

Access Plate

Flex Installation
A
Step 1

Step 1. To insert access
plate, rotate until leading end
is inside the wireway (see A).
Step 2. Fold into horizontal
position and slide forward into
locking position.

Leading
End
Step 2

Figure D.

ADF130660 5/13

ATTENTION

Page 1

Installation de la plaque d'accès
Cooper Lighting 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800

0590AWSIS

Plaque d’accès

METALUX
WaveStream Luminaire Installation Instruction Sheet
Blowing off the Surface of an Optic
Dust and other loose contaminants should be blown off before any other cleaning technique is employed. Using compressed air
over the entire lens is recommended to prevent static buildup.
When using compressed air, hold the can upright throughout the procedure. Also, start the flow of air with the nozzle pointed away
from the lens. Hold the can approximately 6” from the optic and use short bursts. Move the nozzle of the compressed air can over
the optic with the nozzle at a grazing angle to the optical surface in a constant one-way direction. Due to the non-contact and
solvent-free nature of this cleaning method, it should be used as a first step in
cleaning all optics.
WARNING:
Additional Cleaning Methods
Fingerprints and large dust particles can be removed by gently wiping the
surface with a clean microfiber cloth. If additional cleaning is required a mild
solution of distilled water and Dawn® dish soap (between 1:20 and 1:10 parts
Dawn to distilled water, respectively) could be used to wash the lens. The
WaveStream lens should not remain wet any longer than necessary to remove
the contaminants. Dry off surface with deionized air. Avoid pooling of water
as that tends to leave streaks on the optical surface. This method is only
recommended as a last resort as it increases the risk of damaging the lens.

RISK OF FIRE, ELECTRICAL SHOCK, CUTS
AND OR OTHER CASUALTY HAZARDS.
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION
AND OPERATION OF THE PRODUCT AND
THE HAZARDS INVOLVED. COOPER
LIGHTING ASSUMES NO RESPONSIBILITY
FOR CLAIMS BROUGHT ABOUT BY
IMPROPER OR CARELESS INSTALLATION
OR HANDLING OF THIS PRODUCT.

Notes:

NOTE ACTUAL FIXTURE DESCRIPTION OF ANY
SHORTAGE OR NOTICEABLE DAMAGE ON
DELIVERY RECEIPT. FILE CLAIM FOR COMMON
CARRIER (LTL) DIRECTLY WITH CARRIER.
CLAIMS FOR CONCEALED DAMAGE MUST BE
FILED WITHIN 15 DAYS OF DELIVERY. ALL
DAMAGED MATERIAL, COMPLETE WITH ORIGINAL
PACKING MUST BE RETAINED.

RA
G

N
RECY
CL

DABLE

RE

CE

LE

B IO

DE

WARNING

R

Risk of burn. Disconnect
power and allow fixture to
cool before changing bulb
or handling fixture.

AB

CAUTION

NOTICE: IF SUPPLY
WIRES ARE LOCATED
WITHIN 3 INCHES OF
BALLAST, USE WIRE
RATED FOR AT LEAST
90°C (194°F).
U

Edges may cut.
Handle with care.

LE RESO

CAUTION

NOTICE: GREEN
GROUND SCREW
PROVIDED IN
PROPER LOCATION.
DO NOT RELOCATE.

AB

•	For additional information on material compatibility in regard to environmental contact 		
	 with chemicals and solvents please visit http://www.cooperindustries.com/content/		
	public/en/lighting/products/indoor_ceiling_wall_mount_lighting/ceiling_mount/_181854.brands.	
	lighting!metalux!options_accessories.html

ATTENTION: RECEIVING DEPARTMENT

W

	 window cleaners, or other alcohol based cleaners and solvents containing thinners, acetone, 	
	 benzene and tetrachloride.

E

•	Avoid any organic solvents. In addition, avoid any cleaning products including ammonia, ketones, 	

Risk of Fire and Electric
Shock. If not qualified,
consult an electrician.
ADF130660 5/13

Page 2

Cooper Lighting 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800

MISE
EN GARDE :
0590AWSIS

RISQUE D’INCENDIE, DE CHOC ÉLECTRIQUE,



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2013:05:15 16:22:21-04:00
Creator                         : Adobe InDesign CS5.5 (7.5)
Modify Date                     : 2013:05:15 16:22:44-04:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2013:05:15 16:22:44-04:00
Creator Tool                    : Adobe InDesign CS5.5 (7.5)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 13623 bytes, use -b option to extract), (Binary data 12057 bytes, use -b option to extract)
Instance ID                     : uuid:8cc870d6-6dec-444a-9935-279324bfeb92
Document ID                     : xmp.did:01801174072068118083C647501799E8
Original Document ID            : xmp.did:01801174072068118083C647501799E8
Rendition Class                 : proof:pdf
History Action                  : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:01801174072068118083C647501799E8, xmp.iid:07801174072068118083C647501799E8, xmp.iid:08801174072068118083C647501799E8, xmp.iid:39AFF9BC162068118083C647501799E8, xmp.iid:65CB6F39152068118083F583A05744CA, xmp.iid:C1D470C9162068118083F583A05744CA, xmp.iid:0287F6DB182068118083F583A05744CA, xmp.iid:E2D8D664192068118083F583A05744CA, xmp.iid:B0F5E8AD192068118083F583A05744CA, xmp.iid:FECB177407206811822AFF7261727E18, xmp.iid:141F27BF07206811822AFF7261727E18, xmp.iid:86398CF007206811822AFF7261727E18, xmp.iid:6874432608206811822AFF7261727E18, xmp.iid:C0B61F3C08206811822AFF7261727E18, xmp.iid:04463D5A08206811822AFF7261727E18, xmp.iid:3E8B345609206811822AFF7261727E18, xmp.iid:3F8B345609206811822AFF7261727E18, xmp.iid:29C7C1380A206811822AFF7261727E18, xmp.iid:4364025A0A206811822AFF7261727E18, xmp.iid:D333F7780A206811822AFF7261727E18, xmp.iid:81EAA9B60A206811822AFF7261727E18, xmp.iid:82EAA9B60A206811822AFF7261727E18, xmp.iid:938B03B5342068118083E8D3DFB162A5, xmp.iid:D515CA503F2068118083E8D3DFB162A5, xmp.iid:1A6600663F2068118083E8D3DFB162A5, xmp.iid:DD82C1F5432068118083E8D3DFB162A5, xmp.iid:C0C2BD304D2068118083E8D3DFB162A5
History When                    : 2013:05:08 07:40:38-04:00, 2013:05:08 09:10:03-04:00, 2013:05:08 09:10:03-04:00, 2013:05:08 09:30:03-04:00, 2013:05:10 09:27:54-04:00, 2013:05:10 09:39:05-04:00, 2013:05:10 09:53:55-04:00, 2013:05:10 09:57:45-04:00, 2013:05:10 09:59:48-04:00, 2013:05:13 08:29:23-04:00, 2013:05:13 08:31:29-04:00, 2013:05:13 08:32:52-04:00, 2013:05:13 08:34:22-04:00, 2013:05:13 08:34:59-04:00, 2013:05:13 08:35:49-04:00, 2013:05:13 08:42:52-04:00, 2013:05:13 08:44:23-04:00, 2013:05:13 08:49:12-04:00, 2013:05:13 08:50:08-04:00, 2013:05:13 08:51-04:00, 2013:05:13 08:52:43-04:00, 2013:05:13 10:20:04-04:00, 2013:05:15 13:26:57-04:00, 2013:05:15 14:42:54-04:00, 2013:05:15 14:43:29-04:00, 2013:05:15 16:13:36-04:00, 2013:05:15 16:22:13-04:00
History Software Agent          : Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5
History Changed                 : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata
Doc Change Count                : 579
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu