CoreliteCatalog
R Series Corelite_Catalog_09_
2014-11-11
: Pdf 629898-Attachment 629898-Attachment 662401 Batch12 unilog
Open the PDF directly: View PDF
.
Page Count: 176
| Download | |
| Open PDF In Browser | View PDF |
Product Catalog
2009
The climate is changing,
environmentally, economically
and architecturally. Budgets are tightening.
Savings for the end-user, both in the immediate and
long into the future, is now imperative to successful design.
And even with emphasis on supreme efficiency and functionality,
there is still an expectation of fresh, unique aesthetics suitable for
contemporary architecture. It can be a daunting mission for lighting companies.
It can be – unless it’s what you do best...
Innovative engineering and design, dedication to high performance and energy efficiency,
and pioneering use of cutting-edge technologies are all in a day’s work at Corelite.
The goal is to provide designers and owners alike with an arsenal of energy saving
luminaires and platforms to face the challenges of a new energy culture head-on.
4
Table of Contents
RECESSED Fluorescent Luminaires
Class R1-1-3/4” Deep Ultra Shallow Recessed T5 Luminaire ................................................. 14
Class R2-2-7/8” Deep Shallow Recessed T5 Luminaire .......................................................... 16
Class R3-3-3/4” Deep, T5/T8/CFL Recessed Luminaire .......................................................... 18
Class R Retrofit- T5/T8 Field Retrofittable Luminaire ............................................................... 20
SUSPENDED Linear Fluorescent Lighting Systems
Class A Family- Steel, Radiused Profile, T5/T8 Lighting System ............................................. 30
Iridium Family- Steel, Slim Radiused Profile, T5/T8 Lighting System ...................................... 50
Stellar Family- Open Baffle, T5/T8 Lighting System ................................................................ 64
Element- Extruded Aluminum, Rectangular Profile, T5/T8 Lighting System ............................ 82
Loft- Extruded Aluminum, Trapezoidal Profile, T5/T8 Lighting System .................................... 86
Vertechs- Extruded Aluminum, “Stepped” Rectangular Profile, T5/T8 Lighting System .......... 90
Traverse- Extruded Aluminum, Rectangular Profile, T5/T8 Lighting System ............................ 92
Navigator- Extruded Aluminum, Obround Profile, T5/T8 Lighting System ............................... 94
Minigator- Extruded Aluminum, Obround Profile, T5/T8 Lighting System ............................... 96
WALL MOUNTED Linear Fluorescent Lighting Systems
Class A D/I- Open Baffle, Steel, Radiused Profile, T5/T8 Lighting System ............................ 110
Class A D/I- Lensed, Steel, Radiused Profile, T5/T8 Lighting System ................................... 112
Class A Perf- Perf Steel, Radiused Profile, T5/T8 Lighting System ....................................... 114
Class A Indirect- Steel, Radiused Profile, T5/T8 Lighting System ......................................... 116
Iridium- Perf Steel, Slim Radiused Profile, T5/T8 Lighting System ........................................ 118
Stellar- Open Baffle, T5/T8 Lighting System .......................................................................... 120
Element- Extruded Aluminum, Rectangular Profile, T5/T8 Lighting System .......................... 122
Loft- Extruded Aluminum, Trapezoidal Profile, T5/T8 Lighting System .................................. 126
Vertechs- Extruded Aluminum, “Stepped” Rectangular Profile, T5/T8 Lighting System ........ 130
Traverse- Extruded Aluminum, Rectangular Profile, T5/T8 Lighting System .......................... 132
Gator- Extruded Aluminum, Obround Profile, T5/T8 Lighting System ................................... 134
SURFACE MOUNTED Linear Fluorescent Lighting Systems
Class R2 ................................................................................................................................. 142
Class Rs ................................................................................................................................. 144
Stellar Q 2T5 .......................................................................................................................... 146
Stellar Q 2T8 .......................................................................................................................... 148
Stellar 2T5 .............................................................................................................................. 150
Stellar 2T8 .............................................................................................................................. 152
ARCHITECTURAL COVE Fluorescent Lighting Systems
Solo- 1T5 Performance Cove Lighting System ...................................................................... 160
Duo- 2T5/1T8 Performance Cove Lighting System ............................................................... 162
Trio- 2T8 Performance Cove Lighting System ....................................................................... 164
SMART ENVIRONMENTS with Integrated Lighting Controls
Day-Sense, Integral Luminaire Daylight Sensor ..................................................................... 170
2Sense, Integral Luminaire Daylight and PIR Occupancy Sensor .......................................... 171
InClass Command, Classroom Lighting Controls .................................................................. 172
5
CORELITE by Application
Recessed Lighting
Individual recessed fluorescent lighting for
ambient lighting applications
An obvious departure from Corelite’s signature linear
lighting systems, the Class R recessed family redefines not
only Corelite’s brand identity, but the identity of recessed
lighting altogether. The Class R family of luminaires presents
an entirely new pallet of low-profile, low-energy recessed
lighting solutions, suited to even the most challenging
modern application. The driving force behind the Class R
family’s conception was the constrained architectural
environment. Modern architectural projects have greater
material and spatial efficacy, are technologically advanced,
and are more budget conscious than ever. These factors
combined point towards lower ceiling heights, cluttered
plenum spaces, and a specific need for the solutions offered
by Corelite’s Class R series.
Suspended
Continuous ceiling mounted linear fluorescent
lighting for ambient lighting applications
Generous ambient illumination and effective control of
light output are key elements of a productive and efficient
working atmosphere. With the combination of low-glare direct
lighting, optimal for visual tasks, and laterally efficient indirect
lighting, allowing for wide luminaire row spacing, Corelite
offers a unique line of suspended architectural luminaires
perfectly suited to the creation of task-friendly and energy
efficient environments. The product families include an array
of indirect, semi-indirect, and direct-indirect contemporary
interior lighting solutions, ideal for commercial, educational
and institutional applications.
Wall Mounted
Continuous wall mounted linear fluorescent
lighting for ambient lighting applications
Corridors, room perimeters and restrooms, typically
challenging to light properly, are easily illuminated with the
use of wall mounted luminaires. The scale and performance
of Corelite’s wall mount fixtures make them ideal solutions for
narrow spaces or restricted ceiling applications. Innovative
optical design for the widest asymmetrical distribution and
large lumen packages with up to two T5HO lamps serve
only to enhance their performance and appeal. And, as all
Corelite’s wall mount luminaires have a matching suspended
companion, the cohesive aesthetic of the design does not
require compromise with their employment.
6
Surface Mounted
Continuous surface mounted linear fluorescent
lighting for ambient lighting applications
As architectural trends continue to point to the popularity
of remodels and retrofits, Corelite responds with an array
of surface mountable luminaires, aptly suited for the most
challenging renovations. With low impact to the ceiling and
a continued dedication to the highest performance and
design, surface mounted fixtures from Corelite provide the
widest possible light distribution and efficiency for budget
and energy savings without compromising style – an unlikely
ability for traditional surface mount solutions of the past.
Ranging from individual and continuous linear to recessedstyle luminaires, Corelite has the ideal solution for every “re-”
project imaginable.
Cove Lighting
Continuous cove mounted linear fluorescent
lighting for ambient applications
Cove lighting is a powerful tool for discreetly illuminating,
defining, accenting and delineating architectural
environments. When the goal is to hide the lighting elements
while at the same time providing a smooth gradient of
light onto architectural surfaces, free from shadows and
light striations, Corelite Cove Systems provide the means.
Corelite’s optical expertise is highly pronounced in the cove
offering – a line of three distinct profiles, each designed with
specific lamping and optical characteristics that suit any
cove application.
Smart Environments
Continuous ceiling mounted linear fluorescent
lighting for ambient applications
Increasing the intelligence of a project’s lighting systems
with the use of the latest in lighting control technology is
imperative to long-term energy savings, as energy-efficient
luminaires alone can no longer combat the economic and
energy crunch. Lighting controls have the ability to effectively
elevate savings to the next level, and it is with that mind
that Corelite introduces a new system platform: Smart
Environments. Enabling the user to seamlessly integrate
cutting-edge technology into Corelite’s innovative linear
lighting systems, Smart Environments provides a turnkey
package of lighting and controls without the traditional
requirements of system set-up or commissioning.
7
CORELITE by Product Family
Class R
Surface Mount
Recessed
CLASS R1
pg. 14-15
CLASS R2
pg. 16-17
CLASS R3
pg. 18-19
CLASS R
RETROFIT
pg. 20-21
CLASS A
D/I LENSED
pg. 32-33
CLASS A
PERF D/I
pg. 34-35
CLASS A
PERF
pg. 36-37
CLASS A D/I
LENSED WALL
pg. 112-113
CLASS A
PERF WALL
pg. 114-115
CLASS A
INDIRECT WALL
pg. 116-117
CLASS R2
SURFACE
pg. 142-143
CLASS Rs
SURFACE
pg. 144-145
Class A
Suspended
CLASS A
D/I BAFFLE
pg. 30-31
CLASS A
FULL PERF
pg. 38-39
CLASS A
INDIRECT
pg. 40-41
Wall Mount
CLASS A D/I
BAFFLE WALL
pg. 110-111
Stellar
Suspended
STELLAR Q
2T5
pg. 64-65
Wall Mount
STELLAR Q
2T8
pg. 66-67
STELLAR
2T5
pg. 68-69
STELLAR
2T8
pg. 70-71
STELLAR Q
SURFACE 2T8
pg. 148-149
STELLAR
SURFACE 2T5
pg. 150-151
STELLAR
SURFACE 2T8
pg. 152-153
Surface Mount
STELLAR Q
SURFACE 2T5
pg. 146-147
8
STELLAR
4T5/T8
pg. 72-73
STELLAR WALL
2T5
pg. 120-121
Iridium
Suspended
IRIDIUM IQ
BAFFLE pg. 50-51
Wall Mount
IRIDIUM IQ
LENSED pg. 52-53
IRIDIUM D/I
pg. 54-55
IRIDIUM PERF
pg. 56-57
IRIDIUM PERF
WALL pg. 118-119
Element
Loft
Vertechs
Suspended
Suspended
Suspended
ELEMENT
pg. 82-83
ELEMENT MICRO
pg. 84-85
Wall Mount
ELEMENT WALL
pg. 122-123
LOFT
pg. 86-87
LOFT MICRO
pg. 88-89
Wall Mount
ELEMENT MICRO
WALL pg. 124-125
Traverse
LOFT WALL
pg. 126-127
VERTECHS
pg. 90-91
Wall Mount
LOFT MICRO
WALL pg. 128-129
Navigator
VERTECHS
WALL pg. 130-131
Minigator
Suspended
Wall Mount
Suspended
Wall Mount
Suspended
TRAVERSE
pg. 92-93
TRAVERSE WALL
pg. 132-133
NAVIGATOR II
pg. 94-95
GATOR WALL
pg. 134-135
MINIGATOR
pg. 96-97
Cove
COVE SOLO
pg. 160-161
COVE DUO
pg. 162-163
COVE TRIO
pg. 164-165
9
R
E
C
E
S
S
E
D
L o w p ro f i l e . Lo w energ y. Hig h imp act.
In an architectural age where plenum heights are shrinking,
energy costs are rising, and innovation in recessed
lighting has essentially flat-lined, how do you answer to
a specification driven by modern demands? You redefine
the concept of recessed lighting, that’s how.
10
11
Class R
Recessed, Redefined.
Discarding the traditional “box” design, the Class R1 and
R2 boast an innovative and unobtrusive low-profile housing
shape, providing the perfect answer to constrained plenum
space, while the Class R3 provides the broadest selection of
optics and lampings available in a minimized housing scale.
The entire Class R family features low-energy technology
and highly efficient optical engineering to aid in “green”
sustainable design. The ability to retain ceiling heights,
reduce plenum space, and potentially save stories worth of
building materials is perhaps the Class R’s highest impact on
architecture overall. And with the sleek modern design of the
Class R, compromising spaces will no longer have to suffer
from compromised fixture performance or aesthetics.
12
CLASS R1
pg. 14-15
CLASS R2
pg. 16-17
CLASS R3
pg. 18-19
CLASS R RETROFIT
pg. 20-21
13
Class R1
RECESSED | DIRECT | T5 / T5HO
Installing in half the space of
traditional lay-ins, the Class R1 is
the ultra shallow plenum solution.
Micro Baffle
Lens
Round Perf (R1-WP)
Air Return (AR)
(page 22)
Lens Gasketing (LG)
(page 23)
Rectangular Perf
Anti-Microbial (AM)
(page 23)
• 2T5 specific design
• 1-3/4” installed depth
• 80.8% efficiency (R1-WL-2N5-22)
• 4 unique shielding options
• Supports energy saving ballasts and controls
14
Class R2 Surface
(pages 142-143)
Class Rs Surface
(pages 144-145)
RE CESSE D CL ASS R 1
ORDERING INFORMATION:
SAMPLE NUMBER:R1-WL-2N5-1C-UNV-22-T1
23 3/4" [603MM]
Construction: Low profile housing die-formed
20 gauge cold rolled steel with integral
one-piece 20 gauge gear tray. Optional welded
and gasketed construction available for NY
and Chicago Plenum applications. Air Return
also available.
SERIES
R1=Class R1 (1-3/4”) Recessed
Reflectors: High reflectance white powder coat
painted reflector system.
REFLECTOR
W=White
Shielding: Lens secured to housing via injection
molded inserts for easy lamp access.
SHIELDING
B=Micro Baffle
L=Lens
P=Round Perf
R=Rectangular Perf
Lens: Linear prismatic co-extruded acrylic lens
with fully frosted center and clear/frost blended
lens returns.
Micro Baffle: Linear prismatic co-extruded
acrylic lens with white internal micro baffle,
clear center and clear/frost blended lens returns.
NUMBER OF LAMPS
2=2 Lamps
Perf: Linear prismatic co-extruded acrylic lens
with perforated formed steel shield, fully frosted
center and clear/frost blended lens returns.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
RECESSED
1 3/4" [44MM]
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
Electrical: T5/T5HO fixtures use UL listed Class
P, T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD.
WIRING*
C=Standard Circuit
B=Battery
D=Dimming / Step Dimming (see OPTIONS)
E=Emergency
Y=Daylight
T=Nightlight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
1x4
2x2
2x4
Finish: Fixture housings are high reflectance
white using electrostatically applied polyester
powder coat paint.
SIZE
24=2’x4’
22=2’x2’
14=1’x4’
Mounting: Standard flange design works with
most lay-in ceiling types. Integral pry-out tabs
secure luminaire to ceiling grid from above.
Fixture offers tie-in locations for tie-wire on all
corners, consult local code for appropriate
tie-wire recommendations.
CEILING TYPE
T1=1” Grid, Slot-Grid, 9/16” Tegular
T9=9/16” Grid
CC=Concealed Ceiling (see note)
Concealed Ceiling Note: Class R may be
installed into inaccessible ceilings (sheet
rock, wood panel, etc.). This is achieved with
the Metalux DFW series drywall frame-in kit,
ordered separately from Metalux. Specify “CC”
for the Corelite Ceiling Type. Specify the following part numbers separately, from Metalux:
OPTIONS*
AR=Air Return
CP=Chicago Plenum
NY=New York City Construction
AM=Anti-Microbial Coating
LG=Lens Gasketing
W6=6’ Whip Flex
W12=12’ Whip Flex
SD=Step Dimming
For 1x4, order Metalux part #DF-14W-U
For 2x2, order Metalux part #DF-22W-U
For 2x4, order Metalux part #DF-24W-U
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
*Not all options available. Please consult your Cooper Lighting Representative for availability and
technical information. Specifications and dimensions subject to change without notice.
-
-
-
15
Class R2
RECESSED | DIRECT | T5 / T5HO
The Class R2 offers a wide range
of shielding and lamp options in
a minimal shallow profile.
Micro Baffle
Lens
Round Perf (R2-WP)
Air Return (AR)
(page 22)
Lens Gasketing (LG)
(page 23)
Rectangular Perf
Anti-Microbial (AM)
(page 23)
• 2-7/8” installed depth
• 84.2% efficiency (R2-WL-2N5-22)
• Accommodates up to 3 T5 lamps
• 4 unique shielding options
• Supports energy saving ballasts and controls
16
Class R2 Surface
(pages 142-143)
Class Rs Surface
(pages 144-145)
RE CESSE D CL ASS R 2
ORDERING INFORMATION:
SAMPLE NUMBER:R2-WL-2N5-1C-UNV-22-T1
23 3/4" [603MM]
Construction: Low profile housing die-formed
20 gauge cold rolled steel with integral
one-piece 20 gauge gear tray. Optional welded
and gasketed construction available for NY
and Chicago Plenum applications. Air Return
also available.
SERIES
R2=Class R2 (2-7/8”) Recessed
Reflectors: High reflectance white powder coat
painted reflector system.
REFLECTOR
W=White
Shielding: Lens secured to housing via injection
molded inserts for easy lamp access.
SHIELDING
B=Micro Baffle
L=Lens
P=Round Perf
R=Rectangular Perf
Lens: Linear prismatic co-extruded acrylic lens
with fully frosted center and clear/frost blended
lens returns.
Micro Baffle: Linear prismatic co-extruded
acrylic lens with white internal micro baffle,
clear center and clear/frost blended lens returns.
Perf: Linear prismatic co-extruded acrylic lens
with perforated formed steel shield, fully frosted
center and clear/frost blended lens returns.
RECESSED
2-7/8" [73MM]
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
3=3 Lamps
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
Electrical: T5/T5HO fixtures use UL listed Class
P, T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD.
WIRING*
C=Standard Circuit
B=Battery
D=Dimming / Step Dimming (see OPTIONS)
E=Emergency
Y=Daylight
T=Nightlight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
1x4
2x2
2x4
Finish: Fixture housings are high reflectance
white using electrostatically applied polyester
powder coat paint.
SIZE
24=2’x4’
22=2’x2’
14=1’x4’
Mounting: Standard flange design works with
most lay-in ceiling types. Integral pry-out tabs
secure luminaire to ceiling grid from above.
Fixture offers tie-in locations for tie-wire on all
corners, consult local code for appropriate
tie-wire recommendations.
CEILING TYPE
T1=1” Grid, Slot-Grid, 9/16” Tegular
T9=9/16” Grid
CC=Concealed Ceiling (see note)
Concealed Ceiling Note: Class R may be
installed into inaccessible ceilings (sheet
rock, wood panel, etc.). This is achieved with
the Metalux DFW series drywall frame-in kit,
ordered separately from Metalux. Specify “CC”
for the Corelite Ceiling Type. Specify the
following part numbers separately, from
Metalux:
OPTIONS*
AR=Air Return
CP=Chicago Plenum
NY=New York City Construction
AM=Anti-Microbial Coating
LG=Lens Gasketing
W6=6’ Whip Flex
W12=12’ Whip Flex
SD=Step Dimming
For 1x4, order Metalux part #DF-14W-U
For 2x2, order Metalux part #DF-22W-U
For 2x4, order Metalux part #DF-24W-U
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
*Not all options available. Please consult your Cooper Lighting Representative for availability and
technical information. Specifications and dimensions subject to change without notice.
-
-
-
17
Class R3
RECESSED | DIRECT | T5 / T5HO / T8 / CFL
A fully luminous housing and
myriad optical configurations put
Class R3 in a class unto itself.
Micro Baffle
Clear Lens
Frosted Lens
Rectangular Perf Inlay
Round Perf Inlay
(R3-WD)
• 3-3/4” installed depth
• Available in 2’x2’ or 2’x4’ housing sizes
• Accommodates T5, T8 and CFL lamps
• 5 unique shielding options
• Supports energy saving ballasts and controls
18
Class R2 Surface
(pages 142-143)
Class Rs Surface
(pages 144-145)
RE CESSE D CL ASS R 3
ORDERING INFORMATION:
SAMPLE NUMBER:R3-WL-2N5-1C-UNV-22-T1
23 3/4" [603MM]
Construction: Low profile housing die-formed 20
gauge cold rolled steel with integral one-piece
20 gauge gear tray.
SERIES
R3=Class R3 (3-3/4”) Recessed
Reflectors: Micro prismatic acrylic lens
composed of frosted and clear blend.
REFLECTOR
W=White
Shielding: Lens secured to housing via injection
molded inserts for easy lamp access.
SHIELDING
B=Micro Baffle
C=Clear Prismatic
L=Lens
D=Round Perf Inlay
G=Rectangular Perf Inlay
Lens: Linear prismatic co-extruded acrylic lens
with fully frosted center and clear/frost blended
lens returns.
RECESSED
3 3/4" [95MM]
Clear Prismatic: Linear prismatic co-extruded
acrylic lens with clear center and clear/frost
blended lens returns.
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
3=3 Lamps
Micro Baffle: Linear prismatic co-extruded
acrylic lens with white internal micro baffle,
clear center and clear/frost blended lens returns.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
40=40 Watt CFL (2 lamps max)
50=50 Watt CFL (2 lamps max)
55=55 Watt CFL (2 lamps max)
80=80 Watt CFL (1 lamp only)
Perf: Linear prismatic co-extruded acrylic lens
with perforated print inlay, frosted center and
clear/frost blended lens returns.
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
2x2
Electrical: T5/T5HO fixtures use UL listed Class
P, T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quickk wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. CFL fixtures use UL listed
Class P, CFL program rapid start and instant
start universal voltage electronic ballasts, power
factors between 90%-110% depending on
lamp wattage and supply voltage, with less than
10% THD. Fixtures and electrical components
certified to UL and CUL standards.
WIRING*
C=Standard Circuit
B=Battery
D=Dimming / Step Dimming (see OPTIONS)
E=Emergency
Y=Daylight
T=Nightlight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
SIZE
24=2’x4’
22=2’x2’
2x4
Finish: Fixture housings are high reflectance
white using electrostatically applied polyester
powder coat paint.
CEILING TYPE
T1=1” Grid, Slot-Grid, 9/16” Tegular
T9=9/16” Grid
CC=Concealed Ceiling (see note)
Mounting: Standard flange design works with
most lay-in ceiling types. Integral pry-out tabs
secure luminaire to ceiling grid from above.
Fixture offers tie-in locations for tie-wire on all
corners, consult local code for appropriate
tie-wire recommendations.
OPTIONS*
AR=Air Return
CP=Chicago Plenum
W6=6’ Whip Flex
W12=12’ Whip Flex
SD=Step Dimming
Concealed Ceiling Note: Class R may be
installed into inaccessible ceilings (sheet
rock, wood panel, etc.). This is achieved with
the Metalux DFW series drywall frame-in kit,
ordered separately from Metalux. Specify “CC”
for the Corelite Ceiling Type. Specify the
following part numbers separately, from
Metalux:
For 1x4, order Metalux part #DF-14W-U
For 2x2, order Metalux part #DF-22W-U
For 2x4, order Metalux part #DF-24W-U
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
*Not all options available. Please consult your Cooper Lighting Representative for availability and
technical information. Specifications and dimensions subject to change without notice.
-
-
-
19
Class R Retrofit
RECESSED | DIRECT | T5 / T5HO
With several energy saving lamp
configurations, the Class R Retrofit
is the ideal upgrade.
Class R2 Surface
9
Class Rs Surface
RECESSED CLASS R RETROFIT
ORDERING INFORMATION:
SAMPLE NUMBER:RF1-WL-2N5-1C-UNV-24-T1
23 3/4" [603MM]
SERIES
RF1=Class R Retrofit Recessed
Reflectors: High reflectance white powder coat
painted reflector system.
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
3=3 Lamps
Shielding: Lens secured to housing via injection
molded inserts for easy lamp access.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
Lens: Linear prismatic co-extruded acrylic lens
with fully frosted center and clear/frost blended
lens returns.
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
RECESSED
3" [76MM]
Construction: Low profile retrofit housing
is constructed of formed white painted 22
gauge aluminum and stainless steel fasteners.
Combination of housing frame, white painted
pre-wired gear tray, and prepaint Internal
mounting brackets allow for fast and simple
installation into any existing 2x4 parabolic deep
cell luminaire. Simply remove existing reflector
and ballast and quickly install the Retrofit.
REFLECTOR
W=White
SHIELDING
L=Lens
WIRING*
C=Standard Circuit
D=Dimming / Step Dimming (see OPTIONS)
Electrical: T5/T5HO fixtures use UL listed Class
P, T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD.
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
SIZE
24=2’x4’
2x4
Finish: Fixture housings are high reflectance
white using electrostatically applied polyester
powder coat paint.
CEILING TYPE
T1=1” Grid, Slot-Grid, 9/16” Tegular
Mounting: Retrofit hardware consists of a
Reflector Frame, Lens, Prewired Gear Tray, and
End Mounting Brackets. The Contractor simply
removes existing reflectors and ballasts, then
installs end plates with self drilling screws.
Next, the gear tray mounts into end brackets
and frame assembly simply slides onto end
bracket corners.
OPTIONS*
SD=Step Dimming
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
*Not all options available. Please consult your Cooper Lighting Representative for availability and
technical information. Specifications and dimensions subject to change without notice.
-
-
-
10
Taking on obstructions from every angle.
Lift and shift installation in less space.
Whether installing from below the plenum, or sliding over from an adjacent grid space, the Class R’s
innovative “out-of-the-box” chamfered design allows for ease of installation in the tightest of spaces,
and may be installed in half the space required for traditional lay-ins.
Intermittent Obstruction
Continuous Obstruction
Intermittent Obstruction
Continuous Obstruction
3.75”
4.75”
Options
AIR RETURN (AR)
The Class R’s Air Return option is comprised of
a unique perforated housing, which allows for
efficient airflow and reclamation in open spaces.
22
5.25”
RE CESSE D I NSTAL L ATI O N
Blend in and stand out.
Class R has seamless ceiling integration covered.
Whatever your ceiling grid style, the Class R has been uniquely engineered for precise
integration with 4 standard “T” interfaces. This clean and flush finish to typical architectural
ceilings and the attention to detail sets the Class R miles apart from competition.
9/16 Flush (T9)
9/16 Slot Grid (T1)
15/16 Flush (T1)
9/16 Tegular (T1)
Concealed Ceiling (CC)
Metalux™ DF Series Frame-In Kit*
Metalux Part Numbers
1x4=DF-14W-U
2x2=DF-22W-U
2x4=DF-24W-U
*Specify “CC” in the Corelite part number to designate the condition of a
concealed ceiling. Frame-in kit must be ordered separately through Metalux.
LENS GASKETING (LG)
ANTI-MICROBIAL (AM)
The Lens Gasketing option prevents the ingress
of unsightly and unsanitary dust and insects,
and enables easy wipe-down cleaning ideal
for sterile healthcare environments.
The Anti-Microbial coating option thwarts the growth
and dispersion of bacteria, and is beneficial in
environments prone to airborne germs such as
healthcare and childcare facilities.
23
24
25
26
27
S U S P E N D E D
Efficiency
Begets
Efficiency.
With the reflection of light off the ceiling and back down
into work areas, suspended linear indirect fixtures create
softer and more balanced lighting than other systems,
resulting in a reduction of shadows, improved control of
task lighting and uniform ceiling illumination. Engineered
to operate at their peak of efficiency and performance,
suspended Corelite luminaires in turn enable the same for
the occupants of any workspace.
28
29
Class A
One Style, Endless Applications.
The high-performance Class A family is one of Corelite’s
most asked-for signature series. Combining a sleek, elegant
appearance with multiple lamping and distribution options,
Class A luminaires ideally suit contemporary office and
educational environments as well as a variety of other interior
applications calling for fluorescent ambient light. Superior
in its versatility, with myriad end caps and downlight media
options, the Class A family combines the same classic
design and contemporary styling throughout the product
line, allowing for multiple fixture styles in one architectural
project while maintaining a cohesive and fluid visual appeal.
30
CLASS A D/I BAFFLE
pg. 32-33
CLASS A D/I LENSED
pg. 34-35
CLASS A PERF D/I
pg. 36-37
CLASS A PERF
pg. 38-39
CLASS A FULL PERF
pg. 40-41
CLASS A INDIRECT
pg. 42-43
31
Class A D/I Baffle
SUSPENDED | DIRECT-INDIRECT | T5 / T5HO / T8
The Class A D/I offers three innovative
downlight control options for any taskfriendly application.
AB-WB with standard flat end plates
Eclipse Louver
(AB-WE)
Tapered End Cap (ET)
Rounded End Cap (ER)
100% Downlight
Isolators (DL100)
• Additional glare reduction with the
Eclipse louver
• 80% and 100% Downlight Isolators
• Standard Flat or Optional Tapered or
Rounded end caps
32
Class A D/I
Baffle Wall
(pages 110-111)
80% Downlight
Isolators (DL80)
SUSPE NDE D
CL ASS A D/ I B AFF LE
ORDERING INFORMATION:
SAMPLE NUMBER:AB-WB-4T5-1C-UNV-AC48-T1-32’-ET
2-7/8" [73MM]
Construction: Housing is one piece die-formed
20-gauge cold rolled steel, forming a 9”x2-7/8”
architectural profile. Standard 4’-0”, 8’-0”, and
12’-0” fixture lengths combine for continuous
runs.
SERIES
AB=Class A D/I Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish.
OPTICS DOWN
B=Perforated Baffle (standard)
E=Eclipse Louver
Louvers: Standard white aluminum perforated
blades. Optional Eclipse Louver with white
perforated blades and ribbed diffuse anodized
aluminum runners.
NUMBER OF LAMPS
2=2 Lamps
3=3 Lamps
4=4 Lamps
OPTICS UP
W=White
9" [229MM]
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
SUSPENDED
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
48”
96”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
144”
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Plates: Standard laser cut 14-gauge cold
rolled steel, mechanically attached with no
exposed fasteners. Optional die cast aluminum
end caps also available.
OPTIONS
ET=Tapered End Cap
ER=Rounded End Cap
DL100=100% Downlight Isolators for outboard lamps
DL80=80% Downlight Isolators for outboard lamps
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
*Not all options available. Please consult your Cooper Lighting Representative for availability and
technical information. Specifications and dimensions subject to change without notice.
-
-
-
33
Class A D/I Lensed
SUSPENDED | SEMI-INDIRECT | T5 / T5HO / T8
The Class A D/I Lensed provides
semi-indirect distribution with
direct-indirect appeal.
AB-WO with standard flat end plates
Tapered End Cap (ET)
Rounded End Cap (ER)
• Standard Flat or Optional Tapered or
Rounded end caps
34
Class A D/I
Lensed Wall
(pages 112-113)
SUSPE NDE D CL ASS A D/ I L E NSED
ORDERING INFORMATION:
SAMPLE NUMBER:AB-WO-4T5-1C-UNV-AC48-T1-32’-ET
Construction: Housing is one piece die-formed
20-gauge cold rolled steel, forming a 9”x2-7/8”
architectural profile. Standard 4’-0”, 8’-0”, and
12’-0” fixture lengths combine for continuous
runs.
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish.
SERIES
AB=Class A D/I Suspended
OPTICS UP
W=White
OPTICS DOWN
O=White Opal Lens
NUMBER OF LAMPS
2=2 Lamps
3=3 Lamps
4=4 Lamps
Lens: Standard white opal.
2-7/8" [73MM]
9" [229MM]
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical components certified to UL and CUL standards.
SUSPENDED
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
48”
96”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
144”
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Plates: Standard laser cut 14-gauge cold
rolled steel, mechanically attached with no
exposed fasteners. Optional die cast aluminum
end caps also available.
OPTIONS
ET=Tapered End Cap
ER=Rounded End Cap
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
35
Class A Perf D/I
SUSPENDED | DIRECT-INDIRECT | T8
Three stylized louver options
make customization standard
with the Class A Perf D/I.
AP-WB with standard flat end plates
Perforated Baffle
(AP-WB)
Translucent Baffle
(AP-WT)
100% Downlight
Isolator (DL100)
• 100% Downlight Isolator
• Standard Flat or Optional Tapered or
Rounded end caps
36
Semi Specular Baffle
(AP-WM)
Tapered End Cap (ET)
Rounded End Cap (ER)
SUSPE NDE D CL ASS A PE R F D/I
ORDERING INFORMATION:
SAMPLE NUMBER:AP-WB-3T8-1C-UNV-AC48-T1-32’-ET
Construction: Housing is one piece die-formed
20-gauge cold rolled steel, forming a 9”x2-7/8”
architectural profile. Two 13” long perforated
baffle sections integrated with standard 1-5/8”
blade spacing. Standard 4’-0”, 8’-0”, and 12’-0”
fixture lengths combine for continuous runs.
SERIES
AP=Class A Perf D/I Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish.
OPTICS DOWN
B=White Perf Baffle (standard)
T=Translucent Baffle
M=Semi Specular Baffle
Electrical: Fixtures are prewired with quick wire
connectors and use instant start UL listed Class
P, 265ma T8 electronic ballasts, power factor
of 95% with less than 10% THD. Fixtures and
electrical components certified to UL and CUL
standards.
NUMBER OF LAMPS
2=2 Lamps
3=3 Lamps
4=4 Lamps
9" [229MM]
SUSPENDED
2-7/8" [73MM]
OPTICS UP
W=White
LAMP TYPE
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
48”
96”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
144”
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Plates: Standard laser cut 14-gauge cold
rolled steel, mechanically attached with no
exposed fasteners. Optional die cast aluminum
end caps also available.
OPTIONS
ET=Tapered End Cap
ER=Rounded End Cap
DL100=100% Downlight Isolator for inboard lamp
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
37
Class A Perf
SUSPENDED | SEMI-INDIRECT | T5 / T5HO / T8
With classic styling and
high-performance optics, the
applications for Class A Perf
are endless.
AP-WP with standard flat end plates
Tapered End Cap (ET)
Rounded End Cap (ER)
• Standard Flat or Optional Tapered or
Rounded end caps
38
Class A Perf Wall
(pages 114-115)
SUSPE NDE D CL ASS A PE R F
ORDERING INFORMATION:
SAMPLE NUMBER:AP-WP-2T8-1C-UNV-AC48-T1-32’-ET
2-7/8" [73MM]
9" [229MM]
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
SERIES
AP=Class A Perf Suspended
OPTICS UP
W=White
S=Specular
OPTICS DOWN
P=Perforated
NUMBER OF LAMPS
1=1 Lamp (N5, T5)
2=2 Lamps (N5, T5, T8)
3=3 Lamps (N5, T5, T8)
4=4 Lamps (T8)
SUSPENDED
Construction: Housing is one piece die-formed
20-gauge cold rolled steel, forming a 9”x2-7/8”
architectural profile. Perforated sections are
23% open with 0.0625” staggered hole pattern
and opal diffuser. Standard 4’-0”, 8’-0”, and
12’-0” fixture lengths combine for continuous
runs.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
48”
96”
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
144”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Plates: Standard laser cut 14-gauge cold
rolled steel, mechanically attached with no
exposed fasteners. Optional die cast aluminum
end caps also available.
OPTIONS
ET=Tapered End Cap
ER=Rounded End Cap
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
39
Class A Full Perf
SUSPENDED | SEMI-INDIRECT | T5 / T5HO / T8
A subtle sparkle across the entire
fixture makes Class A Full Perf a
standout in its class.
AZ-WP with standard flat end plates
Tapered End Cap (ET)
Rounded End Cap (ER)
• Standard Flat or Optional Tapered or
Rounded end caps
40
Class A Perf Wall
(pages 114-115)
SUSPE NDE D CL ASS A FUL L PERF
ORDERING INFORMATION:
SAMPLE NUMBER:AZ-WP-2T8-1C-UNV-AC48-T1-32’-ET
Construction: Housing is one piece die-formed
20-gauge cold rolled steel, forming a 9”x2-7/8”
architectural profile. Standard 4’-0”, 8’-0”, and
12’-0” fixture lengths combine for continuous
runs.
SERIES
AZ=Class A Full Perf Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish.
OPTICS DOWN
P=Perforated
NUMBER OF LAMPS
2=2 Lamps
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
SUSPENDED
2-7/8" [73MM]
9" [229MM]
OPTICS UP
W=White
NUMBER OF CIRCUITS
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
48”
96”
144”
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Plates: Standard laser cut 14-gauge cold
rolled steel, mechanically attached with no
exposed fasteners. Optional die cast aluminum
end caps also available.
OPTIONS
ET=Tapered End Cap
ER=Rounded End Cap
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
41
Class A Indirect
SUSPENDED | FULL INDIRECT | T5 / T5HO / T8
The Class A Indirect has the greatest
selection of lamp configurations in
the entire linear category.
AI-WN with standard flat end plates
Tapered End Cap (ET)
Rounded End Cap (ER)
• Standard Flat or Optional Tapered or
Rounded end caps
42
Class A
Indirect Wall
(pages 116-117)
SUSPE NDE D CL ASS A I NDI R E CT
ORDERING INFORMATION:
SAMPLE NUMBER:AI-WN-2T8-1C-UNV-AC48-T1-32’-ET
2-7/8" [73MM]
Construction: Housing is one piece die-formed
20-gauge cold rolled steel, forming a 9”x2-7/8”
architectural profile. Standard 4’-0”, 8’-0”, and
12’-0” fixture lengths combine for continuous
runs.
SERIES
AI=Class A Indirect Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
OPTICS UP
W=White
S=Specular
OPTICS DOWN
N=None
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
NUMBER OF LAMPS
1=1 Lamps
2=2 Lamps
3=3 Lamps
4=4 Lamps
SUSPENDED
9" [229MM]
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
48”
96”
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
144”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Plates: Standard laser cut 14-gauge cold
rolled steel, mechanically attached with no
exposed fasteners. Optional die cast aluminum
end caps also available.
OPTIONS
ET=Tapered End Cap
ER=Rounded End Cap
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
43
44
45
46
47
48
49
I rid i um
The Sophistication of Simplicity.
Versatile enough to satisfy any application and sleek enough
to please the most discriminating palette, the Iridium family
presents a complete line of semi-indirect to direct-indirect
luminaires in one series. The innovative Iridium IQ, the “Smart
Fixture”, leads the way in optical and aesthetic flexibility with
the introduction of a third Slide-N-LockTM scale, a second
optional die-cast end cap, and another opportunity to take
advantage of the glare-reduction capability of the Eclipse
Louver. Rounding out the family are the Iridium D/I and
Iridium Perf, which offer a variety of optics and distributions,
enabling spaces designed with varied light levels to achieve
a cohesive aesthetic.
50
IRIDIUM IQ BAFFLE
pg. 52-53
IRIDIUM IQ LENSED
pg. 54-55
IRIDIUM D/I
pg. 56-57
IRIDIUM PERF
pg. 58-59
51
Iridium IQ Baffle
SUSPENDED | DIRECT-INDIRECT | T5 / T5HO / T8
With four innovative downlight controls,
Iridium IQ – the smart fixture – has the
highest IQ in its class.
IQ-WB with standard straight end caps (ES)
Eclipse Louver (IQ-WE)
Beveled End Cap (EB)
Slide-N-Lock™
(pages 98-99)
• Slide-N-Lock™ optics with eight field
adjustable settings
• Standard Straight or optional Beveled end caps
• Additional glare reduction with the
Eclipse Louver
• 80% and 100% Downlight Isolators
52
100% Downlight
Isolators (DL100)
80% Downlight
Isolators (DL80)
SUSPE NDE D I R I DI UM I Q B AFFLE
ORDERING INFORMATION:
SAMPLE NUMBER:IQ-WB-2T8-1C-UNV-AC48-T1-32’-ES
9" [228MM]
SERIES
IQ=Iridium IQ Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
OPTICS DOWN
B=Perforated Baffle (standard)
E=Eclipse Louver
Louvers: Standard white aluminum perforated
blades. Optional Eclipse louver with white
perforated blades and ribbed diffuse anodized
aluminum runners.
OPTICS UP
W=White
S=Specular
NUMBER OF LAMPS
2=2 Lamps (N5, T5, T8)
3=3 Lamps (N5, T5, T8)
4=4 Lamps (T8)
SUSPENDED
2-1/2" [64MM]
Construction: Housing is one piece die-formed
cold rolled steel, forming a 9”x2-1/2”
architectural profile. Standard 4’-0”, 8’-0”,
and 12’-0” fixture lengths combine for
continuous runs.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
48”
96”
144”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Caps: End caps are precision die-cast
aluminum mechanically attached without
exposed fasteners.
OPTIONS
ES=Straight End Cap (provided if none specified)
EB=Beveled End Cap
DL100=100% Downlight Isolators for outboard lamps
DL80=80% Downlight Isolators for outboard lamps
Slide-N-LockkTM (pg. 98-99)
DL1=95% Downlight
DL5=75% Downlight
DL2=90% Downlight
DL6=70% Downlight
DL3=85% Downlight
DL7=65% Downlight
DL4=80% Downlight
DL8=60% Downlight
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
53
Iridium IQ Lensed
SUSPENDED | SEMI-INDIRECT | T5 / T5HO / T8
The Iridium IQ Lensed provides
semi-indirect distribution with
direct-indirect appeal.
IQ-WO with standard straight end caps (ES)
Beveled End Cap (EB)
• Standard Straight or optional Beveled end caps
54
SUSPE NDE D I R I DI UM I Q L E NSED
ORDERING INFORMATION:
SAMPLE NUMBER:IQ-WO-2T8-1C-UNV-AC48-T1-32’-ES
2-1/2" [64MM]
9" [228MM]
Construction: Housing is one piece die-formed
cold rolled steel, forming a 9”x2-1/2”
architectural profile. Standard 4’-0”, 8’-0”,
and 12’-0” fixture lengths combine for
continuous runs.
SERIES
IQ=Iridium IQ Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
OPTICS DOWN
O=White Opal Lens
Lens: Standard white opal.
OPTICS UP
W=White
S=Specular
NUMBER OF LAMPS
2=2 Lamps (N5, T5, T8)
3=3 Lamps (N5, T5, T8)
4=4 Lamps (T8)
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
SUSPENDED
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
48”
96”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
144”
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Caps: End caps are precision die-cast
aluminum mechanically attached without
exposed fasteners.
OPTIONS
ES=Straight End Cap (provided if none specified)
EB=Beveled End Cap
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
55
Iridium D/I
SUSPENDED | DIRECT-INDIRECT / SEMI-INDIRECT | T5 / T5HO / T8
Five unique media options in one
sleek profile make the Iridium D/I
an ideal design solution.
IB-WB with standard straight end caps (ES)
Micro Prismatic Lens
(IB-WM)
Cross Blade Parabolic
Louver (IB-WB)
RPerformance™
Louver (IB-WH)
Beveled End Cap (EB)
Slide-N-Lock™
(pages 98-99)
Lamp Isolators
(pages 98-99)
•
•
•
•
•
56
RPerformance™ louver meets RP1 requirements
Slide-N-Lock™ optics with eight field adjustable settings
Standard Straight or optional Beveled end caps
Five unique louver options
Lamp Isolator kits
Concave Metallic
Perf (IB-WC)
High Efficiency Louver
(IB-WW)
SUSPE NDE D I R I DI UM D/ I
ORDERING INFORMATION:
SAMPLE NUMBER:IB-WB-2T8-1C-UNV-AC48-T1-32’-ES
SERIES
IB=Iridium D/I Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
OPTICS DOWN
B=Cross Blade Parabolic Louver
C=Concave Metallic Perf
H=RPerformance™ Louver
M=Micro Prismatic Lens
W=High Efficiency Louver
Lens: Lens is .125” thick clear microlinear
prismatic acrylic material offering 93%
transmission.
NUMBER OF LAMPS
1=1 Lamp (N5, T5)
2=2 Lamps (N5, T5, T8)
3=3 Lamps (N5, T5)
Louvers: Cross Blade and RPerformance™ are
continuous semi-specular aluminum. Perf is
semi-specular material, perforated section is
15% open with 0.062” diameter holes and opal
diffuser. High Efficiency is continuous highly
reflective painted white aluminum.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0” and 8’-0” centers. Refer to spec sheets
for various ceiling interface details and rigid
pendant mounting details.
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
9" [228MM]
OPTICS UP
W=White
S=Specular
SUSPENDED
2-5/8" [67MM]
Construction: Housing is one piece die-formed
cold rolled steel, forming a 9”x2-1/2”
architectural profile. Standard 4’-0” and 8’-0”
fixture lengths combine for continuous runs.
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
SUSPENSION LENGTH
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
48”
96”
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
End Caps: End caps are precision die-cast
aluminum mechanically attached without
exposed fasteners.
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’ or 8’ in length.
-Continuously Mounted
Standard row configurations over 8’ consist of 4’ and 8’ sections.
OPTIONS*
ES=Straight End Cap (provided if none specified)
EB=Beveled End Cap
Slide-N-LockkTM (pg. 98-99)
DL1=95% Downlight
DL5=75% Downlight
DL2=90% Downlight
DL6=70% Downlight
DL3=85% Downlight
DL7=65% Downlight
DL4=80% Downlight
DL8=60% Downlight
Lamp Isolators (pg. 98-99)
DL/UDU=2 lamps up 1 lamp down
DL/DUD=2 lamps down 1 lamp up
DL/UXU=2 lamps up
DL/DXD=2 lamps down
DL/XUX=1 lamp up
DL/XDX=1 lamp down
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
57
Iridium Perf
SUSPENDED | SEMI-INDIRECT | T5 / T5HO / T8
The Iridium Perf offers sleek
standard features with modern
custom appeal.
IP-WP with standard straight end caps (ES)
Beveled End Cap (EB)
• Straight or optional Beveled end caps
58
Iridium Wall
(pages 118-119)
SUSPE NDE D I R I DI UM PE R F
ORDERING INFORMATION:
SAMPLE NUMBER:IP-WP-2T8-UNV-AC48-T1-32’-ES
Construction: Housing is one piece die-formed
cold rolled steel, forming a 9”x2-1/2”
architectural profile. Standard 4’-0”, 8’-0”,
and 12’-0” fixture lengths combine for
continuous runs.
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
OPTICS UP
W=White
S=Specular
OPTICS DOWN
P=Perforated
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
NUMBER OF LAMPS
1=1 Lamp (N5, T5)
2=2 Lamps (N5, T5, T8)
3=3 Lamps (N5, T5, T8)
4=4 Lamps (T8)
SUSPENDED
2-1/2" [63MM]
9" [228MM]
IP=Iridium Perf Suspended
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
48”
96”
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
144”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End caps: End caps are precision die-cast
aluminum mechanically attached without
exposed fasteners.
OPTIONS
ES=Straight End Cap (provided if none specified)
EB=Beveled End Cap
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
59
60
61
62
63
Stel l a r
A Product of its Surroundings.
The Stellar family of ambient fluorescent lighting, including
the new squared Stellar Q series, features an open-baffle
design to facilitate efficient direct-indirect light distribution,
and a “refined industrial” appearance to echo trends in
architecture where structure is often creatively revealed.
Stellar fixtures deliver high vertical footcandles making them
ideally suited to library stacks and high-ceiling open offices.
Furthermore, Stellar series fixtures offer optional downlight
kits and a unique optional metallic paint finish enabling the
achievement of a truly customized look and feel.
64
STELLAR Q 2T5
pg. 66-67
STELLAR Q 2T8
pg. 68-69
STELLAR 2T5
pg. 70-71
STELLAR 2T8
pg. 72-73
STELLAR 4T5/4T8
pg. 74-75
65
Stellar Q 2T5 (6”)
SUSPENDED | DIRECT-INDIRECT / DIRECT | T5 / T5HO
With its two-lamp T5 specific profile,
the squared Stellar Q stands at the
very edge of modern design.
Q1-WB with standard flat end plates
100% Downlight Kit
(DL100)
70% Downlight Kit
(DL70)
• 2T5 specific design
• 100% or 70% Downlight Kits
66
Stellar Q1 Surface
(pages 146-147)
SUSPE NDE D STE L L AR Q
ORDERING INFORMATION:
SAMPLE NUMBER:Q1-WB-2T5-1C-UNV-AC48-T1-32’-DL70
2-1/2" [64MM]
Construction: Die-formed all aluminum baffle
assembly (1.5” blade spacing) mechanically
attached to a corrosion resistant formed steel
ballast channel. Perforated siderail sections are
23% open with 0.0625” stagger hole spacing.
Standard 4’-0”, 8’-0”, and 12’-0” fixture lengths
combine for continuous runs.
SERIES
Q1=Stellar Q Suspended
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD.
NUMBER OF LAMPS
2=2 Lamps
OPTICS UP
W=White
OPTICS DOWN
B= Baffle
6" [152MM]
SUSPENDED
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
NUMBER OF CIRCUITS
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
48”
96”
144”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint. Consult factory for custom finishes.
End Plates: Laser cut 14-gauge cold rolled
steel, mechanically attached without exposed
fasteners.
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
OPTIONS
DL100=100% Downlight Kit
DL70=70% Downlight Kit
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
67
Stellar Q 2T8 (9”)
SUSPENDED | DIRECT-INDIRECT / DIRECT | T8
With its two-lamp T8 specific profile,
the squared Stellar Q stands at the
very edge of modern design.
Q2-WB with standard flat end plates
100% Downlight Kit
(DL100)
70% Downlight Kit
(DL70)
• 2T8 specific design
• 100% or 70% Downlight Kits
68
Stellar Q2 Surface
(pages 148-149)
SUSPE NDE D STE L L AR Q
ORDERING INFORMATION:
SAMPLE NUMBER:Q2-WB-2T8-1C-UNV-AC48-T1-32’-DL70
Construction: Die-formed all aluminum baffle
assembly (2” blade spacing) mechanically
attached to a corrosion resistant formed steel
ballast channel. Perforated siderail sections are
23% open with 0.0625” stagger hole spacing.
Standard 4’-0”, 8’-0”, and 12’-0” fixture lengths
combine for continuous runs.
SERIES
Q2=Stellar Q Suspended
Electrical: T8 fixtures are pre-wired with quick
wire connectors and use UL listed Class P,
265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
NUMBER OF LAMPS
2=2 Lamps
9" [229MM]
OPTICS DOWN
B= Baffle
LAMP TYPE
T8=T8 Normal Output
SUSPENDED
2-7/8" [73MM]
OPTICS UP
W=White
NUMBER OF CIRCUITS
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
48”
96”
144”
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint. Consult factory for custom finishes.
End Plates: Laser cut 14-gauge cold rolled
steel, mechanically attached without exposed
fasteners.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
OPTIONS
DL100=100% Downlight Kit
DL70=70% Downlight Kit
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
69
Stellar 2T5 (6”)
SUSPENDED | DIRECT-INDIRECT / DIRECT | T5 / T5HO
The industrial styled Stellar
provides three light distributions
for additional flexibility.
S1-WB with standard flat end plates
100% Downlight Kit
(DL100)
70% Downlight Kit
(DL70)
• 2T5 specific design
• 100% or 70% Downlight Kits
70
Stellar Wall
(pages 120-121)
Stellar 2T5 Surface
(pages 150-151)
SUSPE NDE D STE L L AR
ORDERING INFORMATION:
SAMPLE NUMBER:S1-WB-2T5-1C-UNV-AC48-T1-32’-DL70
2-1/2" [64MM]
Construction: Die-formed all aluminum baffle
assembly (1.5” blade spacing) mechanically
attached to a corrosion resistant formed steel
ballast channel. Perforated siderail sections are
23% open with 0.0625” stagger hole spacing.
Standard 4’-0”, 8’-0”, and 12’-0” fixture lengths
combine for continuous runs.
SERIES
S1=Stellar Suspended
Electrical: T5/T5HO fixtures are prewired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD.
NUMBER OF LAMPS
2=2 Lamps
OPTICS UP
W=White
OPTICS DOWN
B= Baffle
6" [152MM]
SUSPENDED
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
NUMBER OF CIRCUITS
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
48”
96”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
144”
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint. Consult factory for custom finishes.
End Plates: Laser cut 14-gauge cold rolled
steel, mechanically attached without exposed
fasteners.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
OPTIONS
DL100=100% Downlight Kit
DL70=70% Downlight Kit
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
71
Stellar 2T8 (9”)
SUSPENDED | DIRECT-INDIRECT / DIRECT | T8
The industrial styled Stellar
provides three light distributions
for additional flexibility.
S2-WB with standard flat end plates
100% Downlight Kit
(DL100)
70% Downlight Kit
(DL70)
• 2T8 specific design
• 100% or 70% Downlight Kits
72
Stellar Wall
(pages 120-121)
Stellar 2T8 Surface
(pages 152-153)
SUSPE NDE D STE L L AR
ORDERING INFORMATION:
SAMPLE NUMBER:S2-WB-2T8-1C-UNV-AC48-T1-32’-DL70
9" [229MM]
SERIES
S2=Stellar Suspended
Electrical: T8 fixtures are pre-wired with quick
wire connectors and use UL listed Class P,
265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
NUMBER OF LAMPS
2=2 Lamps
OPTICS UP
W=White
OPTICS DOWN
B= Baffle
LAMP TYPE
T8=T8 Normal Output
SUSPENDED
2-7/8" [73MM]
Construction: Die-formed all aluminum baffle
assembly (2” blade spacing) mechanically
attached to a corrosion resistant formed steel
ballast channel. Perforated siderail sections are
23% open with 0.0625” stagger hole spacing.
Standard 4’-0”, 8’-0”, and 12’-0” fixture lengths
combine for continuous runs.
NUMBER OF CIRCUITS
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
48”
96”
144”
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint. Consult factory for custom finishes.
End Plates: Laser cut 14-gauge cold rolled
steel, mechanically attached without exposed
fasteners.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
OPTIONS
DL100=100% Downlight Kit
DL70=70% Downlight Kit
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
73
Stellar 4T5/4T8 (12”)
SUSPENDED | DIRECT-INDIRECT / DIRECT | T5 / T5HO / T8
The industrial styled Stellar
provides three light distributions
for additional flexibility.
S4-WB with standard flat end plates
100% Downlight Kit
(DL100)
70% Downlight Kit
(DL70)
• 4-lamp specific design
• 100% or 70% Downlight Kits
74
Stellar Wall
(pages 120-121)
SUSPE NDE D STE L L AR
ORDERING INFORMATION:
SAMPLE NUMBER:S4-WB-4T8-1C-UNV-AC48-T1-32’-DL70
12-3/8" [314MM]
SERIES
S4=Stellar Suspended
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
NUMBER OF LAMPS
4=4 Lamps
OPTICS UP
W=White
OPTICS DOWN
B= Baffle
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
SUSPENDED
3-1/4" [83MM]
Construction: Die-formed all aluminum baffle
assembly (3” blade spacing) mechanically
attached to a corrosion resistant formed steel
ballast channel. Perforated siderail sections are
23% open with 0.0625” stagger hole spacing.
Standard 4’-0”, 8’-0”, and 12’-0” fixture lengths
combine for continuous runs.
NUMBER OF CIRCUITS
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Fixed Cable
12”, 15”, 18”, 21”, 24” or 27” (+/- 1/2” adjustment)
-Adjustable Cable
48”, 120”, 240”, 300”, or 360”
(infinite adjustment along entire length of cable)
48”
96”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
144”
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint. Consult factory for custom finishes.
End Plates: Laser cut 14-gauge cold rolled
steel, mechanically attached without exposed
fasteners.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
OPTIONS
DL100=100% Downlight Kit
DL70=70% Downlight Kit
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
75
76
77
78
79
D/I Extrusions
Versatility. Scalability. Capability.
Corelite’s extensive lines of Direct/Indirect Extruded product
families infallibly provide the simple solution to complex
spaces. The Element, Loft, Vertechs, Traverse and Navigator
families of luminaires offer versatile lighting solutions for
modern architectural spaces with their innovative uplight and
downlight control features and unique scalability between
fixtures. All D/I Extrusion fixtures provide both task and
ambient illumination, while offering elegant styling, extruded
aluminum housings and up to five unique media options.
Corelite’s D/I Extrusions also provide the ideal platform for
the revolutionary Slide-N-Lock™ adjustable optics, as well
as the cutting-edge Smart Environment control system.
80
ELEMENT
pg. 82-83
ELEMENT MICRO
pg. 84-85
LOFT
pg. 86-87
LOFT MICRO
pg. 88-89
VERTECHS
pg. 90-91
TRAVERSE
pg. 92-93
NAVIGATOR II
pg. 94-95
MINIGATOR
pg. 96-97
81
Element
SUSPENDED | DIRECT-INDIRECT / SEMI-INDIRECT | T5 / T5HO / T8
A minimal rectilinear profile with
dedication to innovative optical
controls is the essence of Element.
E2-WM with standard die-cast end caps
Micro Prismatic
Lens (E2-WM)
Cross Blade Parabolic
Louver (E2-WB)
RPerformance™
Louver (E2-WH)
Concave Metallic
Perf (E2-WC)
Slide-N-Lock™
(pages 98-99)
Lamp Isolators
(pages 98-99)
Day-Sense
(page 170)
2Sense
(page 171)
•
•
•
•
•
82
Five downlight media options
RPerformance™ Louver meets RP1 requirements
Slide-N-Lock™ optics with 8 field-adjustable settings
Lamp Isolator kits
Day-Sense integral daylight sensor and 2Sense integral
daylight/occupancy sensor
Element Wall
(pages 122-123)
High Efficiency
Louver (E2-WW)
SUSPE NDE D E L E ME NT
ORDERING INFORMATION:
SAMPLE NUMBER:E2-WM-2N5-1C-UNV-AC48-T1-12
6-3/4" [171MM]
SERIES
E2=Element Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
OPTICS DOWN
B=Cross Blade Parabolic Louver
C=Concave Metallic Perf
H=RPerformance™ Louver
M=Micro Prismatic Lens
W=High Efficiency Louver
Lens: Lens is .125” thickk clear micro-prismatic
acrylic material offering 91% transmission.
Louvers: Cross Blade and RPerformance™ are
continuous semi-specular aluminum. Perf is
semi-specular material, perforated section is
15% open with 0.062” diameter holes and opal
diffuser. High Efficiency is continuous highly
reflective painted white aluminum.
Electrical: T5/T5HO fixtures are pre-wired with
quickk wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quickk wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0” and 12’-0” centers. Refer to
installation section for various ceiling interface
details and rigid pendant mounting details.
OPTICS UP
W=White
S=Specular
NUMBER OF LAMPS
1=1 Lamp (N5, T5)
2=2 Lamps (N5, T5, T8)
3=3 Lamps (N5, T5)
SUSPENDED
2-1/2" [64MM]
Construction: Housing is 6063 T5 aluminum
extrusion forming a 7-1/2” x 2-1/2” rectilinear
profile. Standard 4’-0”, 8’-0” and 12’-0” fixture
lengths combine for continuous runs.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
SUSPENSION LENGTH
-Adjustable Cable
48”, 120”, 240”, 300”, 360”
(infinite adjustment along entire length of cable)
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
48”
96”
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
144”
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
OPTIONS
Slide-N-Lock™ (page 98-99)
DL1=95% Downlight
DL5=75% Downlight
DL2=90% Downlight
DL6=70% Downlight
DL3=85% Downlight
DL7=65% Downlight
DL4=80% Downlight
DL8=60% Downlight
Lamp Isolator Kits* (page 98-99)
DL/UDU=2 lamps up 1 lamp down
DL/DUD=2 lamps down 1 lamp up
DL/UXU=2 lamps up
DL/DXD=2 lamps down
DL/XDX=1 lamp down
DL/XUX=1 lamp up
Dimensions do not include
end plates or caps
DS=Day-Sense Integral Daylight Sensor
2S=2Sense Integral Daylight/Occupancy Sensor
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
all options available. Please consult your Cooper Lighting Representative for availability and
technical information. Specifications and dimensions subject to change without notice.
-
-
-
83
Element Micro
SUSPENDED | DIRECT-INDIRECT | T5 / T5HO / T8
The Element Micro offers
maximized performance in a
modern micro-scaled package.
E1-WM with standard die-cast end caps
Micro Prismatic
Lens (E1-WM)
• Highly efficient micro prismatic lens
84
Element Micro Wall
(pages 124-125)
SUSPE NDE D E L E ME NT MI CR O
ORDERING INFORMATION:
SAMPLE NUMBER:E1-WM-2N5-1C-UNV-AC48-T1-12
5-1/4" [133MM]
SERIES
E1=Element Micro Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
OPTICS DOWN
M=Micro Prismatic Lens
Lens: Lens is .125” thickk clear micro-prismatic
acrylic material offering 91% transmission.
Electrical: T5/T5HO fixtures are pre-wired with
quickk wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quickk wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
OPTICS UP
W=White
S=Specular
NUMBER OF LAMPS
1=1 Lamp (N5, T5, T8)
2=2 Lamps (N5, T5)
SUSPENDED
2-1/2" [64MM]
Construction: Housing is 6063 T5 aluminum
extrusion forming a 5-1/4” x 2-1/2” rectilinear
profile. Standard 4’-0”, 8’-0” and 12’-0” fixture
lengths combine for continuous runs.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0” and 12’-0” centers. Refer to
installation section for various ceiling interface
details and rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
48”
96”
SUSPENSION LENGTH
-Adjustable Cable
48”, 120”, 240”, 300”, 360”
(infinite adjustment along entire length of cable)
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
144”
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
all options available. Please consult your Cooper Lighting Representative for availability and
technical information. Specifications and dimensions subject to change without notice.
-
-
-
85
Loft
SUSPENDED | DIRECT-INDIRECT / SEMI-INDIRECT | T5 / T5HO / T8
The exceptionally versatile Loft
takes efficiency and modern design
sophistication to new heights.
L2-WM with standard die-cast end caps
Micro Prismatic
Lens (L2-WM)
Cross Blade Parabolic
Louver (L2-WB)
RPerformance™
Louver (L2-WH)
Concave Metallic
Perf (L2-WC)
Slide-N-Lock™
(pages 98-99)
Lamp Isolators
(pages 98-99)
Day-Sense
(page 170)
2Sense
(page 171)
•
•
•
•
•
86
Five downlight media options
RPerformance™ Louver meets RP1 requirements
Slide-N-Lock™ optics with 8 field-adjustable settings
Lamp Isolator kits
Day-Sense integral daylight sensor and 2Sense
integral daylight/occupancy sensor
Loft Wall
(pages 126-127)
High Efficiency
Louver (L2-WW)
SUSPE NDE D L O FT
ORDERING INFORMATION:
SAMPLE NUMBER:L2-WM-1T5-1C-UNV-AC48-T1-12
7-1/2" [191MM]
SERIES
L2=Loft Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
OPTICS DOWN
B=Cross Blade Parabolic Louver
C=Concave Metallic Perf
H=RPerformance™ Louver
M=Micro Prismatic Lens
W=High Efficiency Louver
Lens: Lens is .125” thickk clear micro-prismatic
acrylic material offering 91% transmission.
Louvers: Cross Blade and RPerformance™ are
continuous semi-specular aluminum. Perf is
semi-specular material, perforated section is
15% open with 0.062” diameter holes and opal
diffuser. High Efficiency is continuous highly
reflective painted white aluminum.
Electrical: T5/T5HO fixtures are pre-wired with
quickk wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quickk wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0” and 12’-0” centers. Refer to
installation section for various ceiling interface
details and rigid pendant mounting details.
OPTICS UP
W=White
S=Specular
NUMBER OF LAMPS
1=1 Lamp (N5, T5)
2=2 Lamps (N5, T5, T8)
3=3 Lamps (N5, T5)
SUSPENDED
2-1/2" [64MM]
Construction: Housing is 6063 T5 aluminum
extrusion forming a 7-1/2” x 2-1/2” angled
profile. Standard 4’-0”, 8’-0” and 12’-0” fixture
lengths combine for continuous runs.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
SUSPENSION LENGTH
-Adjustable Cable
48”, 120”, 240”, 300”, 360”
(infinite adjustment along entire length of cable)
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
48”
96”
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
144”
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
OPTIONS
Slide-N-Lock™ (page 98-99)
DL1=95% Downlight
DL5=75% Downlight
DL2=90% Downlight
DL6=70% Downlight
DL3=85% Downlight
DL7=65% Downlight
DL4=80% Downlight
DL8=60% Downlight
Lamp Isolator Kits* (page 98-99)
DL/UDU=2 lamps up 1 lamp down
DL/DUD=2 lamps down 1 lamp up
DL/UXU=2 lamps up
DL/DXD=2 lamps down
DL/XDX=1 lamp down
DL/XUX=1 lamp up
Dimensions do not include
end plates or caps
DS=Day-Sense Integral Daylight Sensor
2S=2Sense Integral Daylight/Occupancy Sensor
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
all options available. Please consult your Cooper Lighting Representative for availability and
technical information. Specifications and dimensions subject to change without notice.
-
-
-
87
Loft Micro
SUSPENDED | DIRECT-INDIRECT | T5 / T5HO / T8
The Loft Micro combines
maximized performance with a
uniquely minimalistic profile.
L1-WM with standard die-cast end caps
Micro Prismatic
Lens (L1-WM)
• Highly efficient micro prismatic lens
88
Loft Micro Wall
(pages 128-129)
SUSPE NDE D L O FT MI CR O
ORDERING INFORMATION:
SAMPLE NUMBER:L1-WM-1T5-1C-UNV-AC48-T1-12
Construction: Housing is 6063 T5 aluminum
extrusion forming a 5-7/8” x 2-1/2” angled
profile. Standard 4’-0”, 8’-0” and 12’-0” fixture
lengths combine for continuous runs.
SERIES
L1=Loft Micro Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
OPTICS DOWN
M=Micro Prismatic Lens
2-1/2" [64MM]
5-7/8" [149MM]
Lens: Lens is .125” thickk clear micro-prismatic
acrylic material offering 91% transmission.
OPTICS UP
W=White
S=Specular
NUMBER OF LAMPS
1=1 Lamp (N5, T5, T8)
2=2 Lamps (N5, T5)
Electrical: T5/T5HO fixtures are pre-wired with
quickk wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quickk wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
SUSPENDED
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0” and 12’-0” centers. Refer to
installation section for various ceiling interface
details and rigid pendant mounting details.
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
48”
96”
SUSPENSION LENGTH
-Adjustable Cable
48”, 120”, 240”, 300”, 360”
(infinite adjustment along entire length of cable)
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
144”
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
all options available. Please consult your Cooper Lighting Representative for availability and
technical information. Specifications and dimensions subject to change without notice.
-
-
-
89
Vertechs
SUSPENDED | DIRECT-INDIRECT / SEMI-INDIRECT | T5 / T5HO / T8
Vertechs embodies the twenty-first
century demands of architecturally
attractive and efficient design.
VB-WB with standard die-cast end caps
Micro Prismatic
Lens (VB-WM)
Cross Blade Parabolic
Louver (VB-WB)
RPerformance™
Louver (VB-WH)
Concave Metallic
Perf (VB-WC)
Slide-N-Lock™
(pages 98-99)
Lamp Isolators
(pages 98-99)
Day-Sense
(page 170)
2Sense
(page 171)
•
•
•
•
•
90
Five downlight media options
RPerformance™ Louver meets RP1 requirements
Slide-N-Lock™ optics with 8 field-adjustable settings
Lamp Isolator kits
Day-Sense integral daylight sensor and 2Sense integral
daylight/occupancy sensor
Vertechs Wall
(pages 130-131)
High Efficiency
Louver (VB-WW)
SUSPE NDE D V E RTE CHS
ORDERING INFORMATION:
SAMPLE NUMBER:VB-WB-2T8-1C-UNV-AC48-T1-32’-DL5
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
2-1/2" [64MM]
Lens: Lens is .125” thickk clear micro-prismatic
acrylic material offering 91% transmission.
9" [229MM]
Louvers: Cross Blade and RPerformance™ are
continuous semi-specular aluminum. Perf is
semi-specular material, perforated section is
15% open with 0.062” diameter holes and opal
diffuser. High Efficiency is continuous highly
reflective painted white aluminum.
SERIES
VB=Vertechs Suspended
OPTICS UP
W=White
S=Specular
OPTICS DOWN
B=Cross Blade Parabolic Louver
C=Concave Metallic Perf
H=RPerformance™ Louver
M=Micro Prismatic Lens
W=High Efficiency Louver
NUMBER OF LAMPS
1=1 Lamp (N5, T5)
2=2 Lamps ((N5, T5, T8)
3=3 Lamps (N5, T5)
SUSPENDED
Construction: Housing is 6063 T5 aluminum
extrusion forming a 9”x2-1/2” rectangular
profile. Standard 4’-0”, 8’-0”, and 12’-0” fixture
lengths combine for continuous runs.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
Electrical: T5/T5HO fixtures are pre-wired with
quickk wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quickk wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
WIRING*
C=Standard Circuit
B=Battery Pack
D=Dimming
E=Emergency
Y=Daylight
T=Nightlight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Adjustable Cable
48”, 120”, 240”, 300”, 360”
(infinite adjustment along entire length of cable)
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
48”
96”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
144”
End Caps: Standard end caps are precision diecast aluminum, mechanically attached without
exposed fasteners.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row
w configurations overr 12’ consistt off 8’ and 12’ sections.
OPTIONS
Slide-N-Lock™ (pg. 98-99)
DL1=95% Downlight
DL5=75%
DL2=90% Downlight
DL6=70%
DL3=85% Downlight
DL7=65%
DL4=80% Downlight
DL8=60%
Downlight
Downlight
Downlight
Downlight
Lamp Isolator Kits* (pg. 98-99)
DL/UDU=2 lamps up 1 lamp down
DL/DUD=2 lamps down 1 lamp up
DL/UXU=2 lamps up
DL/DXD=2 lamps down
DL/XDX=1 lamp down
DL/XUX=1 lamp up
Dimensions do not include
end plates or caps
DS=Day-Sense Integral Daylight Sensor
2S=2Sense Integral Daylight/Occupancy Sensor
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
all options available. Please consult your Cooper Lighting Representative for availability and
technical information. Specifications and dimensions subject to change without notice.
-
-
-
91
Traverse
SUSPENDED | DIRECT-INDIRECT / SEMI-INDIRECT | T5 / T5HO / T8
No matter the design goal, the
Traverse is equipped with the
media and controls to achieve it.
TB-WB with standard die-cast end caps
Micro Prismatic
Lens (TB-WM)
Cross Blade Parabolic
Louver (TB-WB)
RPerformance™
Louver (TB-WH)
Concave Metallic
Perf (TB-WC)
Slide-N-Lock™
(pages 98-99)
Lamp Isolators
(pages 98-99)
Day-Sense
(pages 170)
2Sense
(pages 171)
•
•
•
•
•
92
Five downlight media options
RPerformance™ Louver meets RP1 requirements
Slide-N-Lock™ optics with 8 field-adjustable settings
Lamp Isolator kits
Day-Sense integral daylight sensor and 2Sense
integral daylight/occupancy sensor
Traverse Wall
(pages 132-133)
High Efficiency
Louver (TB-WW)
SUSPE NDE D TR AV E R SE
ORDERING INFORMATION:
SAMPLE NUMBER:TB-WB-3T8-1C-UNV-AC48-T1-32
SERIES
TB=Traverse Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
OPTICS DOWN
B=Cross Blade Parabolic Louver
C=Concave Metallic Perf
H=RPerformance™ Louver
M=Micro Prismatic Lens
W=High Efficiency Louver
Lens: Lens is .125” thick clear micro-prismatic
acrylic material offering 91% transmission.
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
3=3 Lamps
9" [229MM]
Louvers: Cross Blade and RPerformance™ are
continuous semi-specular aluminum. Perf is
semi-specular material, perforated section is
15% open with 0.062” diameter holes and opal
diffuser. High Efficiency is continuous highly
reflective painted white aluminum.
OPTICS UP
S=Specular
W=White
SUSPENDED
2-7/8" [73MM]
Construction: Housing is 6063 T5 aluminum
extrusion forming a 9”x2-7/8” rectangular
profile. Standard 4’-0”, 8’-0”, and 12’-0” fixture
lengths combine for continuous runs.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
WIRING*
C=Standard Circuit
B=Battery Pack
D=Dimming
E=Emergency
Y=Daylight
T=Nightlight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
Mounting: Aircraft cable mounts on 4’-0”, 8’-0”,
and 12’-0” centers. Refer to spec sheets for
various ceiling interface details and rigid
pendant mounting details.
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Adjustable Cable
48”, 120”, 240”, 300”, 360”
(infinite adjustment along entire length of cable)
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
48”
96”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
144”
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
OPTIONS
Slide-N-Lock™ (page 98-99)
DL1=95% Downlight
DL5=75% Downlight
DL2=90% Downlight
DL6=70% Downlight
DL3=85% Downlight
DL7=65% Downlight
DL4=80% Downlight
DL8=60% Downlight
Lamp Isolator Kits* (page 98-99)
DL/UDU=2 lamps up 1 lamp down
DL/DUD=2 lamps down 1 lamp up
DL/UXU=2 lamps up
DL/DXD=2 lamps down
DL/XDX=1 lamp down
DL/XUX=1 lamp up
Dimensions do not include
end plates or caps
DS=Day-Sense Integral Daylight Sensor
2S=2Sense Integral Daylight/Occupancy Sensor
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
93
Navigator II
SUSPENDED | DIRECT-INDIRECT / SEMI-INDIRECT | T5 / T5HO / T8
The classic Navigator II, now updated
and tailored to the requirements of
contemporary design.
NB-WB with standard die-cast end caps
Micro Prismatic
Lens (NB-WM)
Cross Blade Parabolic
Louver (NB-WB)
RPerformance™
Louver (NB-WH)
Concave Metallic
Perf (NB-WC)
Slide-N-Lock™
(pages 98-99)
Lamp Isolators
(pages 98-99)
Day-Sense
(page 170)
2Sense
(page 171)
•
•
•
•
•
94
Five downlight media options
RPerformance™ Louver meets RP1 requirements
Slide-N-Lock™ optics with 8 field-adjustable settings
Lamp Isolator kits
Day-Sense integral daylight sensor and 2Sense
integral daylight/occupancy sensor
Gator Wall
(pages 134-135)
High Efficiency
Louver (NB-WW)
SUSPE NDE D NAV I G ATO R I I
ORDERING INFORMATION:
SAMPLE NUMBER:NB-WB-2N5-1C-UNV-AC48-T1-32-DL1
Construction: Housing is 6063 T5 aluminum
extrusion forming a 9”x2-7/8” rounded profile.
Standard 4’-0”, 8’-0”, and 12’-0” fixture lengths
combine for continuous runs.
SERIES
NB=Navigator II Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
OPTICS DOWN
B=Cross Blade Parabolic Louver
C=Concave Metallic Perf
H=RPerformance™ Louver
M=Micro Prismatic Lens
W=High Efficiency Louver
Lens: Lens is .125” thick clear micro-prismatic
acrylic material offering 91% transmission.
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
3=3 Lamps
9" [229MM]
Louvers: Cross Blade and RPerformance™ are
continuous semi-specular aluminum. Perf is
semi-specular material, perforated section is
15% open with 0.062” diameter holes and opal
diffuser. High Efficiency is continuous highly
reflective painted white aluminum.
OPTICS UP
S=Specular
W=White
SUSPENDED
2-7/8" [73MM]
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
WIRING*
C=Standard Circuit
B=Battery Pack
D=Dimming
E=Emergency
Y=Daylight
T=Nightlight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Adjustable Cable
48”, 120”, 240”, 300”, 360”
(infinite adjustment along entire length of cable)
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
48”
96”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
144”
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
OPTIONS
Slide-N-Lock™ (page 98-99)
DL1=95% Downlight
DL5=75% Downlight
DL2=90% Downlight
DL6=70% Downlight
DL3=85% Downlight
DL7=65% Downlight
DL4=80% Downlight
DL8=60% Downlight
Lamp Isolator Kits* (page 98-99)
DL/UDU=2 lamps up 1 lamp down
DL/DUD=2 lamps down 1 lamp up
DL/UXU=2 lamps up
DL/DXD=2 lamps down
DL/XDX=1 lamp down
DL/XUX=1 lamp up
Dimensions do not include
end plates or caps
DS=Day-Sense Integral Daylight Sensor
2S=2Sense Integral Daylight/Occupancy Sensor
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
95
Minigator
SUSPENDED | DIRECT-INDIRECT / SEMI-INDIRECT | T5 / T5HO / T8
The Minigator offers a minimal profile
with the same immense capabilities
as its larger counterpart.
MB-WB with standard die-cast end caps
Micro Prismatic
Lens (MB-WM)
Cross Blade Parabolic
Louver (MB-WB)
RPerformance™
Louver (MB-WH)
Concave Metallic
Perf (MB-WC)
Slide-N-Lock™
(pages 98-99)
Lamp Isolators
(pages 98-99)
Day-Sense
(page 170)
2Sense
(page 171)
•
•
•
•
•
96
Five downlight media options
RPerformance™ Louver meets RP1 requirements
Slide-N-Lock™ optics with 8 field-adjustable settings
Lamp Isolator kits
Day-Sense integral daylight sensor and 2Sense
integral daylight/occupancy sensor
Gator Wall
(pages 134-135)
High Efficiency
Louver (MB-WW)
SUSPE NDE D MI NI G ATO R
ORDERING INFORMATION:
SAMPLE NUMBER:MB-WB-2T8-1C-UNV-AC48-T1-32’-DL5
Construction: Housing is 6063 T5 aluminum
extrusion forming a 6-3/4”x2-1/2” rounded
profile. Standard 4’-0”, 8’-0”, and 12’-0” fixture
lengths combine for continuous runs.
SERIES
MB=Minigator Suspended
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
OPTICS DOWN
B=Cross Blade Parabolic Louver
C=Concave Metallic Perf
H=RPerformance™ Louver
M=Micro Prismatic Lens
W=High Efficiency Louver
Lens: Lens is .125” thick clear micro-prismatic
acrylic material offering 91% transmission.
NUMBER OF LAMPS
1=1 Lamp (N5, T5)
2=2 Lamps (N5, T5, T8)
3=3 Lamps (N5, T5)
6-3/4" [171MM]
Louvers: Cross Blade and RPerformance™ are
continuous semi-specular aluminum. Perf is
semi-specular material, perforated section is
15% open with 0.062” diameter holes and opal
diffuser. High Efficiency is continuous highly
reflective painted white aluminum.
OPTICS UP
W=White
S=Specular
SUSPENDED
2-1/2" [64MM]
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical components certified to UL and CUL standards.
Mounting: Standard aircraft cable mounts on
4’-0”, 8’-0”, and 12’-0” centers. Refer to spec
sheets for various ceiling interface details and
rigid pendant mounting details.
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
SUSPENSION
A=Aircraft Cable
P=Rigid Pendant
POWER FEED*
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
SUSPENSION LENGTH
-Adjustable Cable
48”, 120”, 240”, 300”, 360”
(infinite adjustment along entire length of cable)
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
48”
96”
-Rigid Pendant
12”, 15”, 18”, 21”, 24” or 27”
(additional pendant lengths available, consult factory)
CEILING TYPE*
T1=1” T-Bar
T9=9/16” T-Bar
TS=Slotted T-Bar
ST=Structure
JB=4” Octagonal J-Box
144”
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
OPTIONS
Slide-N-Lock™ (page 98-99)
DL1=95% Downlight
DL5=75% Downlight
DL2=90% Downlight
DL6=70% Downlight
DL3=85% Downlight
DL7=65% Downlight
DL4=80% Downlight
DL8=60% Downlight
Lamp Isolator Kits* (page 98-99)
DL/UDU=2 lamps up 1 lamp down
DL/DUD=2 lamps down 1 lamp up
DL/UXU=2 lamps up
DL/DXD=2 lamps down
DL/XDX=1 lamp down
DL/XUX=1 lamp up
Dimensions do not include
end plates or caps
DS=Day-Sense Integral Daylight Sensor
2S=2Sense Integral Daylight/Occupancy Sensor
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
97
SLIDE-N-LOCK™
The original revolutionary Slide-N-Lock™ optics designed for the Navigator II can
also be specified for all D/I Extruded families. Rather than one optic per configuration,
the Slide-N-Lock™ is a one-size-fits-all optic with 8 settings that are factory preset at the specified level and, if necessary, can later be easily adjusted in the field.
To adjust, simply depress the control notch, then “Slide-N-Lock” the optic into the
new desired setting.
• 8 UPLIGHT AND
DOWNLIGHT SETTINGS
• FULLY FIELD ADJUSTABLE
uplight
95%
downlight
90%
85%
DL2
DL1
80%
DL3
75%
DL4
70%
DL5
75%
DL6
60%
DL7
DL8
*All distributions based on a 2T8 lamping
LAMP ISOLATORS
The ability to isolate uplight and downlight when combined with dual circuit
wiring is an added feature of several Corelite fixtures. This feature is ideal
for training rooms, classrooms and lecture halls where three light levels may
be required to accommodate a variety of room tasks.
• ADDED FLEXIBILITY WITH
DUAL CIRCUIT WIRING
• IDEAL FOR MEDIA
PRESENTATIONS
D-U-D
U=Isolator Up
D=Isolator Down
X=No Isolator
98
D-X-D
X-U-X
U-D-U
U-X-U
X-D-X
A pp l icat io n Ex am p le > Su p erm ark e t – Low-Ene rgy Sta c k s
3 T 8 Tra d i t i o n a l
Scenario 1
•
•
•
•
14’ Ceiling
11.5’ Mounting height
3T8* “Open” configuration
Average Horizontal Illuminance (.8 llf)
Vertical Shelf Surface: 25.9 fc
Floor: 39.5 fc
Ceiling: 114.0 fc
• 1.43 Watts per sq ft
SUMMARY
Scenario 1 illustrates a typical direct-indirect
supermarket application wherein luminaires
are suspended high above the floors and
aligned with the aisles. Although the bright
ceiling surfaces create an "open" feel,
wasted light in the ceiling truss represents
wasted energy.
* Lamp: Standard T8, 3000 initial lumens
Ballast: .88 Ballast factor, 85 input watts
2 T 8 U l t ra E n erg y Effi ci ent
Scenario 2
•
•
•
•
14’ Ceiling
9’ Mounting height
2T8** DL5 ("super" T8) configuration
Average Horizontal Illuminance
Vertical Shelf Surface: 28.8 fc
Floor: 41.5 fc
Ceiling: 19.8 fc
• 0.85 Watts per sq ft
** Lamp: “Super T8”, 3100 Initial Lumens
Ballast: .88 Ballast Factor, 55 input watts
SUMMARY
By lowering the luminaire's mounting
height, eliminating a lamp, utilizing an ultra
energy efficient lamp/ballast combination
and adding Slide-N-Lock™ Optics in the
DL5 configuration, light levels improve
and energy consumption is substantially
reduced. Although the uplight is lowered
dramatically, 25% of the total output still
gently illuminates the ceiling for subtle
luminous effects.
IMPROVED VERTICAL A N D
H O R I Z O N T A L I L LUMINANCE
USING 4 0 % LESS
ENERGY!
A pp l icat io n Ex am p le > Clas s ro om/Tra ining Room
Scenario 1
Scenario 2
Scenario 3
• D-U-D Lamp Isolator configuration
• D-U-D Lamp Isolator configuration
• D-U-D Lamp Isolator configuration
• Outboard lamps at 100%
inboard lamp at 100%
• Outboard lamps off,
inboard lamp at 5%
• Outboard lamps at 100%
inboard lamp off
Maximum system brightness for
clean-up and non-media presentations, notice the screen is washed out.
This setting creates enough ambient
illumination for wayfinding and note
taking while creating ideal projection
screen contrast.
This condition creates recommended
light levels for reading and writing
while also creating great projection
screen contrast by eliminating the
uplight component.
99
100
101
102
103
104
105
W
A
Lighting
Inside
L
The
L
Lines.
From narrow corridors to wide-open office perimeters, wall
mounted luminaires provide the necessary performance
to illuminate the most challenging architectural spaces.
As they share the same uncompromising design sense
with their linear suspended counterparts, Corelite’s wall
mount fixtures maintain the aesthetic synergy of any
project.
106
107
Wal l
It’s All in the Family.
One of Corelite’s most unique attributes is the inclusion of
a wall mount companion for every product family, without
exception. Wall mount fixtures enhance the uniformity and
cohesiveness of the overall aesthetic appeal of a project,
while also adding further flexibility, allowing the designer
to continue with one product family in spaces that are not
conducive to suspended fixtures, such as corridors and
office perimeters. A variety of families also accommodate
the innovative Slide-N-Lock™ adjustable optics and Smart
Environment control systems, and are even ADA compliant.
108
CLASS A D/I
CLASS A D/I
BAFFLE pg. 110-111 LENSED pg. 112-113
CLASS A PERF
pg. 114-115
CLASS A INDIRECT
pg. 116-117
IRIDIUM PERF
pg. 118-119
STELLAR
pg. 120-121
ELEMENT
pg. 122-123
ELEMENT MICRO
pg. 124-125
LOFT
pg. 126-127
LOFT MICRO
pg. 128-129
VERTECHS
pg. 130-131
TRAVERSE
pg. 132-133
ELEMENT
GATOR
pg. 134-135
109
AW-WB with standard flat end plates
Eclipse Louver
(AW-WE)
Tapered End Cap (ET)
Rounded End Cap (ER)
100% Downlight
Isolators (DL100)
• Glare reduction with the Eclipse louver
• 80% and 100% Downlight Isolators
• Standard Flat or Optional Tapered or
Rounded end caps
110
Class A D/I Baffle
Suspended
(pages 32-33)
80% Downlight
Isolators (DL80)
WALL CL ASS A D/ I B AFFL E
ORDERING INFORMATION:
SAMPLE NUMBER:AW-WB-2T8-1C-UNV-SU-WA-12’-ET
2-7/8" [73MM]
6-1/2" [165MM]
Construction: Housing is one piece die-formed
cold rolled steel, forming a 6”x2-7/8” architectural profile. Standard 4’-0”, 8’-0”, and 12’-0”
fixture lengths combine for continuous runs.
SERIES
AW=Class A D/I Wall
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish.
OPTICS UP
W=White
Louvers: Standard white aluminum perforated
blades. Optional Eclipse Louver with white
perforated blades and ribbed diffuse anodized
aluminum runners.
OPTICS DOWN
B=Perforated Baffle (Standard)
E=Eclipse Louver
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WALL
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
48”
96”
144”
Mounting: Fixture mounts directly to existing
structure over a 2”x4” standard electrical box
mounted horizontally into the wall.
MOUNTING
SU-WA=Surface Wall Mount
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’
sections.
End Plates: Standard laser cut 14-gauge cold
rolled steel, mechanically attached with no
exposed fasteners. Optional die cast aluminum
end caps also available.
OPTIONS
ET=Tapered End Cap
ER=Rounded End Cap
DL100=100% Downlight Isolator for outboard lamp
DL80=80% Downlight Isolator for outboard lamp
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
111
AW-WO with standard flat end plates
Tapered End Cap (ET)
Rounded End Cap (ER)
• Standard Flat or Optional Tapered or
Rounded end caps
112
Class A D/I Lensed
Suspended
(pages 34-35)
WALL CL ASS A D/ I L E NSE D
ORDERING INFORMATION:
SAMPLE NUMBER:AW-WO-2T8-1C-UNV-SU-WA-12’-ET
2-7/8" [73MM]
Construction: Housing is one piece die-formed
cold rolled steel, forming a 6”x2-7/8” architectural profile. Standard 4’-0”, 8’-0”, and 12’-0”
fixture lengths combine for continuous runs.
SERIES
AW=Class A D/I Wall
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish.
OPTICS UP
W=White
Lens: Standard white opal.
OPTICS DOWN
O=White Opal Lens
6-1/2" [165MM]
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
WALL
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
48”
96”
144”
Mounting: Fixture mounts directly to existing
structure over a 2”x4” standard electrical box
mounted horizontally into the wall.
MOUNTING
SU-WA=Surface Wall Mount
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Plates: Standard laser cut 14-gauge cold
rolled steel, mechanically attached with no
exposed fasteners. Optional die cast aluminum
end caps also available.
OPTIONS
ET=Tapered End Cap
ER=Rounded End Cap
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
113
AW-SP with standard flat end plates
Tapered End Cap (ET)
Rounded End Cap (ER)
• Standard Flat or Optional Tapered or
Rounded end caps
114
Class A Perf
Suspended
(pages 38-39)
WALL CL ASS A PE R F
ORDERING INFORMATION:
SAMPLE NUMBER:AW-SP-2T8-1C-UNV-SU-WA-12’-ET
Construction: Housing is one piece die-formed
cold rolled steel, forming a 6”x2-7/8”
architectural profile. Perforated section is 23%
open with 0.0625” staggered hole pattern and
opal diffuser. Standard 4’-0”, 8’-0”, and 12’-0”
fixture lengths combine for continuous runs.
SERIES
AW=Class A Perf Wall
Reflectors: Die-formed reflectors are highly
specular anodized aluminum.
OPTICS UP
S=Specular
OPTICS DOWN
P=Perforated
2-7/8" [73MM]
6-1/2" [165MM]
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WALL
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
48”
96”
144”
Mounting: Fixture mounts directly to existing
structure over a 2”x4” standard electrical box
mounted horizontally into the wall.
MOUNTING
SU-WA=Surface Wall Mount
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Plates: Standard laser cut 14-gauge cold
rolled steel, mechanically attached with no
exposed fasteners. Optional die cast aluminum
end caps also available.
OPTIONS
ET=Tapered End Cap
ER=Rounded End Cap
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
115
AW-SN with standard flat end plates
Tapered End Cap (ET)
Rounded End Cap (ER)
• Standard Flat or Optional Tapered or
Rounded end caps
116
Class A Indirect
Suspended
(pages 42-43)
WALL CL ASS A I NDI R E CT
ORDERING INFORMATION:
SAMPLE NUMBER:AW-SN-2T8-1C-UNV-SU-WA-12’-ET
Construction: Housing is one piece die-formed
cold rolled steel, forming a 6”x2-7/8”
architectural profile. Standard 4’-0”, 8’-0”,
and 12’-0” fixture lengths combine for
continuous runs.
SERIES
AW=Class A Indirect Wall
Reflectors: Die-formed reflectors are highly
specular anodized aluminum.
OPTICS UP
S=Specular
OPTICS DOWN
N=None
2-7/8" [73MM]
6-1/2" [165MM]
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WALL
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
48”
96”
144”
Mounting: Fixture mounts directly to existing
structure over a 2”x4” standard electrical box
mounted horizontally into the wall.
MOUNTING
SU-WA=Surface Wall Mount
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Plates: Standard laser cut 14-gauge cold
rolled steel, mechanically attached with no
exposed fasteners. Optional die cast aluminum
end caps also available.
OPTIONS
ET=Tapered End Cap
ER=Rounded End Cap
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
117
IW-SP with standard Straight end caps (ES)
Beveled End Cap (EB)
• Standard Straight or optional Beveled end caps
118
Iridium Perf
Suspended
(pages 58-59)
WALL I R I DI UM PE R F
ORDERING INFORMATION:
SAMPLE NUMBER:IW-SP-2T8-1C-UNV-SU-WA-8’-ES
Construction: Housing is one piece die-formed
cold rolled steel, forming a 6-1/2”x2-1/2”
architectural profile. Standard 4’-0” and 8’-0”
fixture lengths combine for continuous runs.
SERIES
IW=Iridium Wall
Reflectors: Die-formed reflectors are highly
specular anodized aluminum.
OPTICS UP
S=Specular
OPTICS DOWN
P=Perforated
2-1/2" [63MM]
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
7" [178MM]
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WALL
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
48”
Mounting: Fixture mounts directly to existing
structure over a 2”x4” standard electrical box
mounted horizontally into the wall.
MOUNTING
SU-WA=Surface Wall Mount
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’ or 8’ in length.
-Continuously Mounted
Standard row configurations over 8’ consist of 4’ and 8’ sections.
End caps: End caps are precision die-cast
aluminum,mechanically attached without
exposed fasteners.
OPTIONS
ES=Straight End Cap (provided if none specified)
EB=Beveled End Cap
96”
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
119
SW-WB with standard flat end plates
100% Downlight Kit
(DL100)
70% Downlight Kit
(DL70)
• 100% or 70% Downlight Kits
120
Stellar Suspended
(pages 70-71)
Stellar Surface
(pages 150-151)
WALL STE L L AR
ORDERING INFORMATION:
SAMPLE NUMBER:SW-WB-1T8-1C-UNV-SU-WA-12’-DL70
3-1/4" [83MM]
6-1/2" [165MM]
Construction: Die-formed all aluminum baffle
assembly (2” blade spacing) mechanically
attached to a corrosion resistant formed steel
ballast channel. Perforated side rail sections are
23% open with 0.0625” stagger hole spacing.
Standard 4’-0”, 8’-0”, and 12’-0” fixture lengths
combine for continuous runs.
SERIES
SW=Stellar Wall
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
NUMBER OF LAMPS
1=1 Lamp (N5, T5, T8)
2=2 Lamps (N5, T5)
OPTICS UP
W=White
OPTICS DOWN
B=Baffle
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
48”
96”
WALL
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Fixture mounts directly to existing
structure over a 2”x4” standard electrical box
mounted horizontally into the wall. Field
adjustable brackets (+/-3°) allow for perfect
continuous alignment.
MOUNTING
SU-WA=Surface Wall Mount
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint. Consult factory for custom finishes.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’ and 12’ sections.
End Plates: End plates are laser cut 14-gauge
cold rolled steel.
OPTIONS
DL100=100% Downlight Kit
DL70=70% Downlight Kit
144”
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
121
E2W-WM with standard die-cast end caps
Micro Prismatic
Lens (E2W-WM)
Cross Blade Parabolic
Louver (E2W-WB)
RPerformance™
Louver (E2W-WH)
Slide-N-Lock™
(pages 98-99)
Day-Sense
(pages 170)
2Sense
(pages 171)
•
•
•
•
122
Concave Metallic
Perf (E2W-WC)
Five downlight media options
RPerformance™ Louver meets RP1 requirements
Slide-N-Lock™ optics with 8 field-adjustable settings
Day-Sense integral daylight sensor and 2Sense integral
daylight/occupancy sensor
Element Suspended
(pages 82-83)
High Efficiency
Louver (E2W-WW)
WALL E L E ME NT
ORDERING INFORMATION:
SAMPLE NUMBER:E2W-WM-1T5-1C-UNV-SU-WA-8’-DL8
2-1/2" [64MM]
7-1/8" [181MM]
Construction: Housing is 6063 T5 aluminum
extrusion forming a 6-5/8” x 2-1/2” rectangular
profile. Standard 4’-0” and 8’-0” fixture lengths
combine for continuous runs.
SERIES
E2W=Element Wall
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish with one
die-formed highly specular anodized aluminum
side reflector.
OPTICS UP
W=White
S=Specular
Lens: Lens is .125” thick clear micro-prismatic
acrylic material offering 91% transmission.
OPTICS DOWN
B=Cross Blade Parabolic Louver
C=Concave Metallic Perf
H=RPerformance™ Louver
M=Micro Prismatic Lens
W=High Efficiency Louver
Louvers: Cross Blade and RPerformance™ are
continuous semi-specular aluminum. Perf is
semi-specular material, perforated section is
15% open with 0.062” diameter holes and opal
diffuser. High Efficiency is continuous highly
reflective painted white aluminum.
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WALL
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Fixture mounts directly to existing
structure over a 2”x4” standard electrical box
mounted horizontally into the wall.
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
48”
96”
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
MOUNTING
SU-WA=Surface Wall Mount
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’ or 8’ in length.
-Continuously Mounted
Standard row configurations over 8’ consist of 4’ and 8’ sections.
OPTIONS
Slide-N-Lock™ (pg. 98-99)
DL1=95% Downlight
DL5=75% Downlight
DL2=90% Downlight
DL6=70% Downlight
DL3=85% Downlight
DL7=65% Downlight
DL4=80% Downlight
DL8=60% Downlight
DS=Day-Sense Integral Daylight Sensor
2S=2Sense Integral Daylight/Occupancy Sensor
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
123
E1W-SM with standard die-cast end caps
Micro Prismatic
Lens (E1W-WM)
• Highly efficient micro prismatic lens
• ADA compliant
124
Element Micro
Suspended
(pages 84-85)
WALL E L E ME NT MI CR O
ORDERING INFORMATION:
SAMPLE NUMBER:E1W-SM-1T5-1C-UNV-SU-WA-8’-DL8
2-1/2" [64MM]
3-3/4"
[95MM]
Construction: Housing is 6063 T5 aluminum
extrusion forming a 3-1/4” x 2-1/2” rectangular
profile. Standard 4’-0” and 8’-0” fixture lengths
combine for continuous runs.
SERIES
E1W=Element Micro Wall
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish with one
die-formed highly specular anodized aluminum
side reflector.
OPTICS UP
S=Specular
Lens: Lens is .125” thick clear micro-prismatic
acrylic material offering 91% transmission.
OPTICS DOWN
M=Micro Prismatic Lens
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD.
NUMBER OF LAMPS
1=1 Lamp
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
WALL
Mounting: Fixture mounts directly to existing
structure over a 2”x4” standard electrical box
mounted horizontally into the wall.
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
MOUNTING
SU-WA=Surface Wall Mount
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’ or 8’ in length.
-Continuously Mounted
Standard row configurations over 8’ consist of 4’ and 8’ sections.
48”
96”
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
125
L2W-WM with standard die-cast end caps
Micro Prismatic
Lens (L2W-WM)
Cross Blade Parabolic
Louver (L2W-WB)
RPerformance™
Louver (L2W-WH)
Slide-N-Lock™
(pages 98-99)
Day-Sense
(pages 170)
2Sense
(pages 171)
•
•
•
•
126
Concave Metallic
Perf (L2W-WC)
Five downlight media options
RPerformance™ Louver meets RP1 requirements
Slide-N-Lock™ optics with 8 field-adjustable settings
Day-Sense integral daylight sensor and 2Sense integral
daylight/occupancy sensor
Loft Suspended
(pages 86-87)
High Efficiency
Louver (L2W-WW)
WALL L O FT
ORDERING INFORMATION:
SAMPLE NUMBER:L2W-WM-1T5-1C-UNV-SU-WA-8’-DL8
2-1/2" [64MM]
Construction: Housing is 6063 T5 aluminum
extrusion forming a 6-7/8” x 2-1/2” angled
profile. Standard 4’-0” and 8’-0” fixture lengths
combine for continuous runs.
SERIES
L2W=Loft Wall
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish with one
die-formed highly specular anodized aluminum
side reflector.
OPTICS UP
W=White
S=Specular
Lens: Lens is .125” thick clear micro-prismatic
acrylic material offering 91% transmission.
OPTICS DOWN
B=Cross Blade Parabolic Louver
C=Concave Metallic Perf
H=RPerformance™ Louver
M=Micro Prismatic Lens
W=High Efficiency Louver
Louvers: Cross Blade and RPerformance™ are
continuous semi-specular aluminum. Perf is
semi-specular material, perforated section is
15% open with 0.062” diameter holes and opal
diffuser. High Efficiency is continuous highly
reflective painted white aluminum.
7-3/8" [187MM]
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WALL
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Fixture mounts directly to existing
structure over a 2”x4” standard electrical box
mounted horizontally into the wall.
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
48”
96”
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
MOUNTING
SU-WA=Surface Wall Mount
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’ or 8’ in length.
-Continuously Mounted
Standard row configurations over 8’ consist of 4’ and 8’ sections.
OPTIONS
Slide-N-Lock™ (pg. 98-99)
DL1=95% Downlight
DL5=75% Downlight
DL2=90% Downlight
DL6=70% Downlight
DL3=85% Downlight
DL7=65% Downlight
DL4=80% Downlight
DL8=60% Downlight
DS=Day-Sense Integral Daylight Sensor
2S=2Sense Integral Daylight/Occupancy Sensor
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
127
L1W-SM with standard die-cast end caps
Micro Prismatic
Lens (E1W-WM)
• Highly efficient micro prismatic lens
• ADA compliant
128
Loft Micro
Suspended
(pages 88-89)
WALL L O FT MI CR O
ORDERING INFORMATION:
SAMPLE NUMBER:L1W-SM-1T5-1C-UNV-SU-WA-8’-DL8
SERIES
L1W=Loft Micro Wall
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish with one
die-formed highly specular anodized aluminum
side reflector.
OPTICS UP
S=Specular
Lens: Lens is .125” thick clear micro-prismatic
acrylic material offering 91% transmission.
OPTICS DOWN
M=Micro Prismatic Lens
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
4" [102MM]
Mounting: Fixture mounts directly to existing
structure over a 2”x4” standard electrical box
mounted horizontally into the wall.
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
NUMBER OF LAMPS
1=1 Lamp
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
WALL
2-1/2" [64MM]
Construction: Housing is 6063 T5 aluminum
extrusion forming a 3-1/2” x 2-1/2” angled profile. Standard 4’-0” and 8’-0” fixture lengths
combine for continuous runs.
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
MOUNTING
SU-WA=Surface Wall Mount
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’ or 8’ in length.
-Continuously Mounted
Standard row configurations over 8’ consist of 4’ and 8’ sections.
48”
96”
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
129
VW-SM with standard die-cast end caps
Micro Prismatic Lens
(VW-SM)
Cross Blade Parabolic
Louver (VW-SB)
RPerformance™
Louver (VW-SH)
Slide-N-Lock™
(pages 98-99)
Day-Sense
(pages 170)
2Sense
(pages 171)
•
•
•
•
130
Concave Metallic
Perf (VW-SC)
Five downlight media options
RPerformance™ Louver meets RP1 requirements
Slide-N-Lock™ optics with 8 field-adjustable settings
Day-Sense integral daylight sensor and 2Sense integral
daylight/occupancy sensor
Vertechs
Suspended
(pages 90-91)
High Efficiency
Louver (VW-SW)
WALL V E RTE CHS
ORDERING INFORMATION:
SAMPLE NUMBER:VW-SB-2T8-1C-UNV-SU-WA-8’-DL5
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish with one
die-formed highly specular anodized aluminum
side reflector.
Lens: Lens is .125” thick clear micro-prismatic
acrylic material offering 91% transmission.
2-1/2" [64MM]
8-1/4" [210MM]
Louvers: Cross Blade and RPerformance™ are
continuous semi-specular aluminum. Perf is
semi-specular material, perforated section is
15% open with 0.062” diameter holes and opal
diffuser. High Efficiency is continuous highly
reflective painted white aluminum.
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
Series
VW=Vertechs Wall
OPTICS UP
S=Specular
OPTICS DOWN
B=Cross Blade Parabolic Louver
C=Concave Metallic Perf
H=RPerformance™ Louver
M=Micro Prismatic Lens
W=High Efficiency Louver
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
WALL
Construction: Housing is 6063 T5 aluminum
extrusion forming a 7-3/4” x 2-1/2” rectangular
profile. Standard 4’-0” and 8’-0” fixture lengths
combine for continuous runs.
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Fixture mounts directly to existing
structure over a 2”x4” standard electrical box
mounted horizontally into the wall.
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
48”
96”
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
MOUNTING
SU-WA=Surface Wall Mount
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’ or 8’ in length.
-Continuously Mounted
Standard row configurations over 8’ consist of 4’ and 8’ sections.
OPTIONS
Slide-N-Lock™ (pg. 98-99)
DL1=95% Downlight
DL5=75% Downlight
DL2=90% Downlight
DL6=70% Downlight
DL3=85% Downlight
DL7=65% Downlight
DL4=80% Downlight
DL8=60% Downlight
DS=Day-Sense Integral Daylight Sensor
2S=2Sense Integral Daylight/Occupancy Sensor
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
131
TW-WM with standard die-cast end caps
Micro Prismatic Lens
(TW-WM)
Cross Blade Parabolic
Louver (TW-WB)
RPerformance™
Louver (TW-WH)
Slide-N-Lock™
(pages 98-99)
Day-Sense
(pages 170)
2Sense
(pages 171)
•
•
•
•
132
Concave Metallic
Perf (TW-WC)
Five downlight media options
RPerformance™ Louver meets RP1 requirements
Slide-N-Lock™ optics with 8 field-adjustable settings
Day-Sense integral daylight sensor and 2Sense integral
daylight/occupancy sensor
Traverse
Suspended
(pages 92-93)
High Efficiency
Louver (TW-WW)
WALL TR AV E R SE
ORDERING INFORMATION:
SAMPLE NUMBER:TW-WB-1T8-1C-UNV-SU-WA-12’
Construction: Housing is 6063 T5 aluminum
extrusion forming a 6-3/8”x2-7/8” rectangular
profile. Standard 4’-0” and 8’-0” fixture lengths
combine for continuous runs.
SERIES
TW=Traverse Wall
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflectors are highly specular
anodized aluminum.
OPTICS DOWN
B=Cross Blade Parabolic Louver
C=Concave Metallic Perf
H=RPerformance™ Louver
M=Micro Prismatic Lens
W=High Efficiency Louver
Lens: Lens is .125” thick clear micro-prismatic
acrylic material offering 91% transmission.
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
Louvers: Cross Blade and RPerformance™ are
continuous semi-specular aluminum. Perf is
semi-specular material, perforated section is
15% open with 0.062” diameter holes and opal
diffuser. High Efficiency is continuous highly
reflective painted white aluminum.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
2-7/8" [73MM]
6-7/8" [174MM]
OPTICS UP
S=Specular
W=White
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
Mounting: Fixture mounts directly to existing
structure over a 2”x4” standard electrical box
mounted horizontally into the wall.
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
48”
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
WALL
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
MOUNTING
SU-WA=Surface Wall Mount
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’ or 8’ in length.
-Continuously Mounted
Standard row configurations over 8’ consist of 4’ and 8’ sections.
OPTIONS
Slide-N-Lock™ (pg. 98-99)
DL1=95% Downlight
DL5=75% Downlight
DL2=90% Downlight
DL6=70% Downlight
DL3=85% Downlight
DL7=65% Downlight
DL4=80% Downlight
DL8=60% Downlight
96”
DS=Day-Sense Integral Daylight Sensor
2S=2Sense Integral Daylight/Occupancy Sensor
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
133
GW-WH with standard die-cast end caps
Micro Prismatic Lens
(GW-WM)
Cross Blade Parabolic
Louver (GW-WB)
RPerformance™
Louver (GW-WH)
Slide-N-Lock™
(pages 98-99)
Day-Sense
(pages 170)
2Sense
(pages 171)
•
•
•
•
134
Concave Metallic
Perf (GW-WC)
High Efficiency
Louver (GW-WW)
Navigator
Suspended
(pages 94-95)
Minigator
Suspended
(pages 96-97)
Five downlight media options
RPerformance™ Louver meets RP1 requirements
Slide-N-Lock™ optics with 8 field-adjustable settings
Day-Sense integral daylight sensor and 2Sense integral
daylight/occupancy sensor
WALL G ATO R
ORDERING INFORMATION:
SAMPLE NUMBER:GW-WB-2T8-1C-UNV-SU-WA-8’-DL5
2-7/8" [73MM]
Construction: Housing is 6063 T5 aluminum
extrusion forming a 6-3/8” x 2-7/8” rounded
profile. Standard 4’-0” and 8’-0” fixture lengths
combine for continuous runs.
GW=Gator Wall
Reflectors: Reflector pan is painted with a high
reflectance white powder coat finish. Optional
die-formed side reflector is a highly specular
anodized aluminum.
OPTICS UP
S=Specular
W=White
Lens: Lens is .125” thick clear micro-prismatic
acrylic material offering 91% transmission.
OPTICS DOWN
B=Cross Blade Parabolic Louver
C=Concave Metallic Perf
H=RPerformance™ Louver
M=Micro Prismatic Lens
W=High Efficiency Louver
Louvers: Cross Blade and RPerformance™ are
continuous semi-specular aluminum. Perf is
semi-specular material, perforated section is
15% open with 0.062” diameter holes and opal
diffuser. High Efficiency is continuous highly
reflective painted white aluminum.
6-7/8" [174MM]
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
WALL
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quick wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Fixture mounts directly to existing
structure over a 2”x4” standard electrical box
mounted horizontally into the wall.
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint.
48”
96”
End Caps: Standard end caps are precision
die-cast aluminum, mechanically attached
without exposed fasteners.
MOUNTING
SU-WA=Surface Wall Mount
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’ or 8’ in length.
-Continuously Mounted
Standard row configurations over 8’ consist of 4’ and 8’ sections.
OPTIONS
Slide-N-Lock™ (pg. 98-99)
DL1=95% Downlight
DL5=75% Downlight
DL2=90% Downlight
DL6=70% Downlight
DL3=85% Downlight
DL7=65% Downlight
DL4=80% Downlight
DL8=60% Downlight
DS=Day-Sense Integral Daylight Sensor
2S=2Sense Integral Daylight/Occupancy Sensor
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
135
136
137
S
N o
U
R
F
S t r i n g s
A
C
E
A t t a c h e d .
It is always a challenge to illuminate open spaces with low
or obstructed ceilings where wall mounted fixtures alone
cannot suffice, yet the benefits and aesthetics of linear
architectural lighting are still desired. Surface mounted
fixtures, with the same wide light distribution and row
spacing as their suspended and recessed counterparts,
offer an attractive architectural solution.
138
139
Surf a c e
No plenum? No problem.
Whether the preference is individual recessed or
continuous linear suspended, and when the ceiling
allows neither, Corelite has the surface mounted solution
to satisfy. In applications with compromised plenums
– or none at all – Corelite offers a surface mountable
alternative to the recessed Class R series, in both
traditional and linear forms. For spaces with low ceilings
or tall interior elements, library stacks for example, both
the Stellar and Stellar Q linear series’ provide effective
and attractive surface mount options.
140
CLASS R2
pg. 142-143
CLASS Rs
pg. 144-145
STELLAR Q 2T5
pg. 146-147
STELLAR Q 2T8
pg. 148-149
STELLAR 2T5
pg. 150-151
STELLAR 2T8
pg. 152-153
141
Class R2 Surface
SURFACE MOUNT | DIRECT | T5 / T5HO
The Class R2 Surface mount is the
ultimate obstructed plenum solution
with recessed appeal.
Micro Baffle
Lens
Round Perf (R2-WP)
Rectangular Perf
Lens Gasketing (LG)
• Minimal 3” frame height
• 84.2% efficiency (R2-WL-2N5-22)
• Accommodates up to 3 T5 lamps
• Four unique shielding options
• Supports energy saving ballasts and controls
142
Class R2 Recessed
(pages 16-17)
SURFACE CL ASS R 2
ORDERING INFORMATION:
SAMPLE NUMBER:R2-WB-2N5-1C-UNV-22-SU
3" [76MM]
23 3/4" [603MM]
Construction: Low profile housing die-formed 20
gauge cold rolled steel with integral one-piece
20 gauge gear tray. Surface mounting kit with
snap-together frame design constructed of dieformed 20 gauge cold rolled steel.
SERIES
R2=Class R2 (3”) Surface
Reflectors: High reflectance white powder coat
painted reflector system.
REFLECTOR
W=White
Shielding: Lens secured to housing via injection
molded inserts for easy lamp access.
SHIELDING
B=Micro Baffle
L=Lens
P=Round Perf
R=Rectangular Perf
Lens: Linear prismatic co-extruded acrylic lens
with fully frosted center and clear/frost blended
lens returns.
Micro Baffle: Linear prismatic co-extruded
acrylic lens with white internal micro baffle,
clear center and clear/frost blended lens returns.
NUMBER OF LAMPS
1=1 Lamp
2=2 Lamps
3=3 Lamps
Perf: Linear prismatic co-extruded acrylic lens
with perforated formed steel shield, fully frosted
center and clear/frost blended lens returns.
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD.
WIRING*
C=Standard Circuit
B=Battery
D=Dimming / Step Dimming (see OPTIONS)
E=Emergency
Y=Daylight
T=Nightlight
Finish: Fixture housings and surface mount kits
are high reflectance white using electrostatically
applied polyester powder coat paint.
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Mounting: Surface mount kit installs easily with
four (4) 1/4-20 screws. Frame mounts first onto
surface, by others. Fixture housing slides into
open end of frame and remaining frame piece
snaps into place for seamless finish. See
installation instructions for further detail.
2x4
CEILING TYPE
SU=Surface Mount
OPTIONS
LG=Lens Gasketing
SD=Step Dimming
PROJECT NAME:
CATALOG #:
SURFACE
SIZE
24=2’x4’
22=2’x2’
2x2
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
143
Class Rs Surface
SURFACE MOUNT | DIRECT | T5 / T5HO
Lower ceiling heights, not expectations,
with the T5-specific micro-scaled linear
Class Rs Surface.
Rectangular Perf
Lens
Micro Baffle
Round Perf (RB-WP)
• Accommodates 2 T5 or T5HO lamps
• Four unique shielding options
• Individual 4’ units only
144
Class R2 Recessed
(pages 16-17)
SURFACE CL ASS R s
ORDERING INFORMATION:
SAMPLE NUMBER:RB-WL-2N5-1C-UNV-SU-JB
1 3/4" [44MM]
6" [152MM]
Construction: Formed 20 gauge steel gear tray
mounts to shielding via 2 factory supplied clips.
SERIES
RB=Class Rs Surface
Reflectors: High reflectance white powder coat
painted reflector system.
OPTICS UP
W=White
Shielding: Lens secured to housing via injection
molded inserts for easy lamp access.
OPTICS DOWN
B=Micro Baffle
L=Lens
P=Round Perf
R=Rectangular Perf
Lens: Linear prismatic co-extruded acrylic lens
with fully frosted center and clear/frost blended
lens returns.
Micro Baffle: Linear prismatic co-extruded
acrylic lens with white internal micro baffle,
clear center and clear/frost blended lens returns.
Perf: Linear prismatic co-extruded acrylic lens
with perforated formed steel shield, fully frosted
center and clear/frost blended lens returns.
NUMBER OF LAMPS
2=2 Lamps
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD.
WIRING*
C=Standard Circuit
B=Battery
D=Dimming / Step Dimming (see OPTIONS)
E=Emergency
Y=Daylight
T=Nightlight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
MOUNTING
SU-JB=Surface Mount
OPTIONS*
SD=Step Dimming
SURFACE
Mounting: Class Rs is for individual surface
mounting only. Luminaire requires 2 factory
supplied formed steel painted mounting clips
to be installed to structure with hardware by
others (see installation instructions). Fixture then
temporarily hangs onto clips to allow hands-free
wiring, then fixture swings into place and is
ultimately secured by factory supplied hardware.
End Caps: Injection-molded plastic end caps.
48”
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
145
Stellar Q 2T5 (6”) Surface
SURFACE MOUNT | DIRECT | T5 / T5HO
With its two-lamp T5 specific profile, the
squared Stellar Q Surface stands at the
very edge of modern design.
Q1-WB with standard flat end plates
100% Downlight Kit
(DL100)
70% Downlight Kit
(DL70)
• 2T5 specific design
• 100% or 70% Downlight Kits
146
Stellar Q1
Suspended
(pages 66-67)
SURFACE STE L L AR Q
ORDERING INFORMATION:
SAMPLE NUMBER:Q1-WB-2T5-1C-UNV-SU-JB-32’-DL100
2-1/2" [64MM]
6" [152MM]
Construction: Die-formed all aluminum baffle
assembly (1.5” blade spacing) mechanically
attached to a corrosion resistant formed steel
ballast channel. Perforated siderail sections are
23% open with 0.0625” stagger hole spacing.
Standard 4’-0”, 8’-0”, and 12’-0” fixture lengths
combine for continuous runs.
SERIES
Q1=Stellar Q Surface
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD.
OPTICS UP
W=White
OPTICS DOWN
B= Baffle
NUMBER OF LAMPS
2=2 Lamps
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
NUMBER OF CIRCUITS
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
48”
96”
144”
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint. Consult factory for custom finishes.
MOUNTING
SU-JB=Surface Mount
SURFACE
Mounting: Crossbar cover supports the fixture
at the power mount and connects to 4”
octagonal junction box, by others. All other
mounts interface to 1/4”-20 studs by others,
protruding from the ceiling. The first suspension
point is the length of the fixture less 2-3/8”, all
other suspension points are 4’, 8’ or 12’
on-center. See installation instructions.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’
and 12’ sections.
OPTIONS
DL100=100% Downlight Kit
(recommended for surface mount applications)
DL70=70% Downlight Kit
End Plates: Laser cut 14-gauge cold rolled
steel, mechanically attached without exposed
fasteners.
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
147
Stellar Q 2T8 (9”) Surface
SURFACE MOUNT | DIRECT | T8
With its two-lamp T8 specific profile, the
squared Stellar Q Surface stands at the
very edge of modern design.
Q2-WB with standard flat end plates
100% Downlight Kit
(DL100)
70% Downlight Kit
(DL70)
• 2T8 specific design
• 100% or 70% Downlight Kits
148
Stellar Q2
Suspended
(pages 68-69)
SURFACE STE L L AR Q
ORDERING INFORMATION:
SAMPLE NUMBER:Q2-WB-2T8-1C-UNV-SU-JB-32’-DL100
2-7/8" [73MM]
9" [229MM]
Construction: Die-formed all aluminum baffle
assembly (2” blade spacing) mechanically
attached to a corrosion resistant formed steel
ballast channel. Perforated siderail sections are
23% open with 0.0625” stagger hole spacing.
Standard 4’-0”, 8’-0”, and 12’-0” fixture lengths
combine for continuous runs.
SERIES
Q2=Stellar Q Surface
Electrical: T8 fixtures are pre-wired with quick
wire connectors and use UL listed Class P,
265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
OPTICS UP
W=White
OPTICS DOWN
B= Baffle
NUMBER OF LAMPS
2=2 Lamps
LAMP TYPE
T8=T8 Normal Output
NUMBER OF CIRCUITS
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
48”
96”
144”
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint. Consult factory for custom finishes.
MOUNTING
SU-JB=Surface Mount
SURFACE
Mounting: Crossbar cover supports the fixture
at the power mount and connects to 4”
octagonal junction box, by others. All other
mounts interface to 1/4”-20 studs by others,
protruding from the ceiling. The first suspension
point is the length of the fixture less 2-3/8”, all
other suspension points are 4’, 8’ or 12’
on-center. See installation instructions.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’
and 12’ sections.
OPTIONS
DL100=100% Downlight Kit
(recommended for surface mount applications)
DL70=70% Downlight Kit
End Plates: Laser cut 14-gauge cold rolled
steel, mechanically attached without exposed
fasteners.
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
149
Stellar 2T5 (6”) Surface
SURFACE MOUNT | DIRECT | T5 / T5HO
The industrial styled Stellar Surface
provides efficient direct illumination in the
most challenging spaces.
S1-WB with standard die-cast end caps
100% Downlight Kit
(DL100)
70% Downlight Kit
(DL70)
• 2T5 specific design
• 100% or 70% Downlight Kits
150
Stellar 2T5
Suspended
(pages 70-71)
Stellar Wall
(pages 120-121)
SURFACE STE L L AR
ORDERING INFORMATION:
SAMPLE NUMBER:S1-WB-2T5-1C-UNV-SU-JB-12’-DL100
Construction: Die-formed all aluminum baffle
assembly (1.5” blade spacing) mechanically
attached to a corrosion resistant formed steel
ballast channel. Perforated siderail sections are
23% open with 0.0625” stagger hole spacing.
Standard 4’-0”, 8’-0”, and 12’-0” fixture lengths
combine for continuous runs.
SERIES
S1=Stellar Surface
2-1/2" [64MM]
OPTICS UP
W=White
6" [152MM]
OPTICS DOWN
B= Baffle
Electrical: T5/T5HO fixtures are pre-wired with
quick wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD.
NUMBER OF LAMPS
2=2 Lamps
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
48”
96”
144”
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint. Consult factory for custom finishes.
MOUNTING
SU-JB=Surface Mount
SURFACE
Mounting: Crossbar cover supports the fixture
at the power mount and connects to 4”
octagonal junction box, by others. All other
mounts interface to 1/4”-20 studs by others,
protruding from the ceiling. The first suspension
point is the length of the fixture less 2-3/8”, all
other suspension points are 4’, 8’ or 12’
on-center. See installation instructions.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’
and 12’ sections.
OPTIONS
DL100=100% Downlight Kit
(recommended for surface mount applications)
DL70=70% Downlight Kit
End Plates: Laser cut 14-gauge cold rolled
steel, mechanically attached without exposed
fasteners.
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
151
Stellar 2T8 (9”) Surface
SURFACE MOUNT | DIRECT | T8
The industrial styled Stellar Surface
provides efficient direct illumination in the
most challenging spaces.
S2-WB with standard die-cast end caps
100% Downlight Kit
(DL100)
70% Downlight Kit
(DL70)
• 2T8 specific design
• 100% or 70% Downlight Kits
152
Stellar 2T8
Suspended
(pages 72-73)
Stellar Wall
(pages 120-121)
SURFACE STE L L AR
ORDERING INFORMATION:
SAMPLE NUMBER:S2-WB-2T8-1C-UNV-SU-JB-12’-DL100
Construction: Die-formed all aluminum baffle
assembly (2”blade spacing) mechanically
attached to a corrosion resistant formed steel
ballast channel. Perforated siderail sections are
23% open with 0.0625” stagger hole spacing.
Standard 4’-0”, 8’-0”, and 12’-0” fixture lengths
combine for continuous runs.
S2=Stellar Surface
OPTICS UP
W=White
OPTICS DOWN
B= Baffle
2-7/8" [73MM]
Electrical: T8 fixtures are pre-wired with quick
wire connectors and use UL listed Class P,
265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical
components certified to UL and CUL standards.
9" [229MM]
NUMBER OF LAMPS
2=2 Lamps
LAMP TYPE
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
48”
96”
144”
Finish: Fixture housings are standard white
using electrostatically applied polyester powder
coat paint. Consult factory for custom finishes.
MOUNTING
SU-JB=Surface Mount
SURFACE
Mounting: Crossbar cover supports the fixture
at the power mount and connects to 4”
octagonal junction box, by others. All other
mounts interface to 1/4”-20 studs by others,
protruding from the ceiling. The first suspension
point is the length of the fixture less 2-3/8”, all
other suspension points are 4’, 8’ or 12’
on-center. See installation instructions.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 4’,8’, or 12’ in length.
-Continuously Mounted
Standard row configurations over 12’ consist of 8’
and 12’ sections.
OPTIONS
DL100=100% Downlight Kit
(recommended for surface mount applications)
DL70=70% Downlight Kit
End Plates: Laser cut 14-gauge cold rolled
steel, mechanically attached without exposed
fasteners.
Dimensions do not include
end plates or caps
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
technical information. Specifications and dimensions subject to change without notice.
-
-
-
153
154
155
C
O
V
E
Highlight The Subject, Not The Source.
Cove lighting is commonly used to accent archetectural
surfaces and details while completely concealing the
lamp source. A splash of light on the ceiling can change
the character of a room by giving it a larger, more open
feel. All of Corelite’s cove luminaires may also function
as a primary source of general illumination by combining
either 2T5 or 2T8 lumen packages with optically designed
asymmetric reflector systems.
156
157
Navigator II
A Means to Every End...
Co v e
One of These Three is Just Right.
The Corelite Cove series of luminaires aim to be wholly
complementary to any application. Corelight Cove series
luminaires carry three specific lumen packages that easily
address changing scales within architectural spaces. The
Cove Solo offers a micro-profile 1-1/2” x 6” 1T5 dedicated
housing, while the Duo offers two lamping options, 2T5
and 1T8, in a mid-sized 2” x 6” housing. The large scale
Trio maximizes the performance of a 2T8 lamping in an
efficiently engineered 2-7/8” x 8-1/2” housing. Ideas of
scale in architecture are extended by the component of
light, and it is the goal of the Corelite Cove Series to do
just that.
158
SOLO
pg. 160-161
DUO
pg. 162-163
TRIO
pg. 164-165
159
Solo
COVE MOUNT | ASYMMETRIC INDIRECT | T5 / T5HO
The Cove Solo offers T5 lampspecific lengths to go the distance in
preventing socket shadows.
Plus 5 Aiming System
(P5)
• Plus5TM Adjustable Aiming System
• Standard 2’, 3’, 4’ and 8’ nominal fixture lengths
• Optimizes single T5 lamp performance
160
CO V E SO L O
ORDERING INFORMATION:
SAMPLE NUMBER:CS-SN-1T5-1C-UNV-8’-P5
1 1/2" [38 MM]
Construction: Housing is one piece die-formed
20-gauge corrosion resistant steel, forming a
1 1/2” deep ballast channel. Standard nominal
2’-0”, 3’-0”, 4’-0”, and 8’-0” fixture lengths
combine for continuous runs.
SERIES
CS=Cove Solo
Reflectors: Die-formed reflectors are highly
specular anodized aluminum.
OPTICS UP
S=Specular
6" [152 MM]
OPTICS DOWN
N=None
Electrical: Fixtures are prewired with quickk wire
connectors and use UL listed Class P, T5/T5HO
program rapid start universal voltage electronic
ballasts. Power factor of 97% with less than
10% THD. Fixtures and electrical components
certified to UL and CUL standards.
21955
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
1098
0098
988
549
49
Finish: Reflector pans are anodized aluminum.
Ballast channels are corrosion resistant steel.
Options: Plus5 Adjustable Aiming System allows
for 5 degree incremental adjustments.
OPTIONS
P5=Plus5 Aiming System
96”
COVE
48”
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 2’,3’, 4’, or 8’ in length.
-Continuously Mounted
Standard row configurations over 8’ consist of 4’ and 8’ sections.
2’ and 3’ sections will be used for row lengths other than in 4’
increments.
1T5/1T5HO
36”
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
NUMBER OF CIRCUITS*
1=1 Circuit
1646
4
46
24”
NUMBER OF LAMPS
1=1 Lamp
Front Mount
Degree of Lift
Back Mount
1-1/2 x 6
0 (Standard)
1-1/2 x 6
2x6
5
1-7/8 x 6-1/8
2-1/2 x 6
10
2-1/8 x 6-1/4
3 x 5-3/4
15
2-1/2 x 6-1/4
3-1/2 x 5-5/8
20
2-3/4 x 6-1/8
3-7/8 x 5-1/2
25
3x6
4-1/4 x 5-1/4
30
3-3/8 x 6
Note: Fixture lengths shown are nominal
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
all options available. Please consult your Cooper Lighting Representative for availability and
technical information. Specifications and dimensions subject to change without notice.
-
-
-
161
Duo
COVE MOUNT | ASYMMETRIC INDIRECT | T5 / T5HO / T8
Optimizing dual T5 and single T8
lampings, the Cove Duo is the
solution for any cove application.
Plus 5 Aiming System
(P5)
• Plus5TM Adjustable Aiming System
• Standard 2’, 3’, 4’ and 8’ fixture lengths
• Optimizes single T8 and dual T5/T5HO
lamp performance
162
CO V E DUO
ORDERING INFORMATION:
SAMPLE NUMBER:CD-SN-1T8-1C-UNV-8’-P5
2" [51 MM]
Construction: Housing is one piece die-formed
20-gauge corrosion resistant steel, forming a
2” deep ballast channel. Standard 2’-0”, 3’-0”,
4’-0”, and 8’-0” fixture lengths combine for
continuous runs.
6" [152 MM]
SERIES
CD=Cove Duo
OPTICS UP
S=Specular
Reflectors: Die-formed reflectors are
highly specular anodized aluminum.
OPTICS DOWN
N=None
Electrical: T5/T5HO fixtures are pre-wired with
quickk wire connectors and use UL listed Class P,
T5/T5HO program rapid start universal voltage
electronic ballasts, power factor of 97% with
less than 10% THD. T8 fixtures are pre-wired
with quickk wire connectors and use UL listed
Class P, 265ma T8 instant start universal voltage
electronic ballasts, power factor of 95% with
less than 10% THD. Fixtures and electrical components certified to UL and CUL standards.
3001
011
2250
5
50
1500
500
00
NUMBER OF LAMPS
1=1 Lamp (T8)
2=2 Lamps (N5, T5)
LAMP TYPE
N5=T5 Normal Output
T5=T5 High Output
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
750
50
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
2T5/2T5HO
Finish: Reflector pans are anodized aluminum.
Ballast channels are corrosion resistant steel.
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 2’,3’, 4’, or 8’ in length.
-Continuously Mounted
Standard row configurations over 8’ consist of 4’ and 8’ sections.
2’ and 3’ sections will be used for row lengths other than in 4’
increments.
Options: Plus5 Adjustable Aiming System allows
for 5 degree incremental adjustments.
OPTIONS
P5=Plus5 Aiming System
36”
48”
96”
COVE
24”
Front Mount
Degree of Lift
Back Mount
2x6
0 (Standard)
2x6
2-1/2 x 6-1/8
5
2-1/2 x 6-1/8
3 x 6-1/4
10
3 x 6-1/4
3-1/2 x 6-1/4
15
3-1/2 x 6-1/4
4 x 6-1/4
20
3-7/8 x 6-1/4
4-3/8 x 6-1/4
25
4-1/4 x 6-1/4
4-3/4 x 6-1/4
30
4-3/4 x 6-1/4
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
all options available. Please consult your Cooper Lighting Representative for availability and
technical information. Specifications and dimensions subject to change without notice.
-
-
-
163
Trio
COVE MOUNT | ASYMMETRIC INDIRECT | T8
Engineered for a dual T8 lamp
configuration, the Cove Trio is the
most commanding of the line.
Plus 5 Aiming System
(P5)
• Plus5TM Adjustable Aiming System
• Standard 2’, 3’, 4’ and 8’ fixture lengths
• Optimizes dual T8 lamp performance
164
CO V E TR I O
ORDERING INFORMATION:
SAMPLE NUMBER:CT-SN-1T8-1C-UNV-8’-P5
2 7/8" [73 MM]
8 1/2" [215 MM]
Construction: Housing is one piece die-formed
20-gauge corrosion resistant steel, forming a
3” deep ballast channel. Standard 2’-0”, 3’-0”,
4’-0”, and 8’-0” fixture lengths combine for
continuous runs.
Reflectors: Highly specular anodized aluminum
strip in housing to enhance output.
SERIES
CT=Cove Trio
OPTICS UP
S=Specular
OPTICS DOWN
N=None
Electrical: Fixtures are prewired with quickk wire
connectors and use instant start UL listed Class
P, 265ma T8 electronic ballasts. Power factor
of 95% with less than 10% THD. Fixtures and
electrical components certified to UL and CUL
standards.
NUMBER OF LAMPS
2=2 Lamps
LAMP TYPE
T8=T8 Normal Output
NUMBER OF CIRCUITS*
1=1 Circuit
2=2 Circuits
2361
611
1777700
WIRING*
C=Standard Circuit
D=Dimming
E=Emergency
B=Battery Pack
T=Nightlight
Y=Daylight
118
180
800
590
90
VOLTAGE*
120=120V
277=277V
347=347V
UNV=Universal (120V-277V)
Finish: Reflector pans are pre-paint white 90%
reflective aluminum. Ballast channels are
corrosion resistant steel.
2T8
RUN LENGTH
Specify luminaire length in feet.
-Individually Mounted
Luminaires may be 2’,3’, 4’, or 8’ in length.
-Continuously Mounted
Standard row configurations over 8’ consist of 4’ and 8’ sections.
2’ and 3’ sections will be used for row lengths other than in 4’
increments.
Options: Plus5 Adjustable Aiming System allows
for 5 degree incremental adjustments.
OPTIONS
P5=Plus5 Aiming System
36”
48”
96”
COVE
24”
Front Mount
Degree of Lift
Back Mount
2-7/8 x 8-1/2
0 (Standard)
2-7/8 x 8-1/2
3-5/8 x 8-1/2
5
3 x 8-3/4
4-1/4 x 8-1/4
10
3-1/4 x 8-7/8
5x8
15
3-1/2 x 9
5-5/8 x 7-3/4
20
3-1/2 x 9
6-1/4 x 7-1/2
25
3-3/4 x 9
6-3/4 x 7
30
4 x 8-7/8
PROJECT NAME:
CATALOG #:
TYPE:
-
-
-
-
-
all options available. Please consult your Cooper Lighting Representative for availability and
technical information. Specifications and dimensions subject to change without notice.
-
-
-
165
166
167
S
M
A
R
T
ENVIRONMENTS
Sm a r t e r T h a n T he Av erag e Sys tem.
More than ever, reigning in energy expenses and harnessing
the power of natural resources – sunlight, for example –
are imperative to operational success. It is Corelite’s goal
to provide as many cutting-edge tools to make doing so
not just possible for those in the know, but simple and
accessible for everyone. With so much intelligence ingrained
in Corelite’s platforms, just sit back and let it do what it does
best: save you money.
Who’s the smart one now?
168
169
SM ART E N VI RONME NT S
D AY- S E N S E ™
The Day-Sense sensor is an innovative
in-fixture energy saving device. It
detects an influx of daylight, and in
turn automatically dims a fluorescent
luminaire, or series of luminaires. This
sensor is manually adjustable to allow
for greater or lesser sensitivity to light
dependent upon user preference.
Watts/Sq. ft.
•
•
•
•
•
•
•
•
•
Watts/Sq. ft.
Watts/Sq. ft.
Manually adjustable “Iris” type sensor allows user to set light sensitivity
Footcandle Range: Application specific, consult factory
Controls any 0-10 volt dimming ballast (no dimming controls required)
Wall dimming controls not required, works with simple on/off switch
Commissioning not required
1 Day-Sense sensor controls up to 20 ballasts
Recommended for use in small private offices and conference rooms with windows
Maximum recommended mounting height: 10’
Available with all Corelite D/I Extrusion families
How to order:
L2-WM-2T5-1D-120-AC48-T1-12-DS
Note: Day-Sense (DS) must be specified with Dimming (D) and specific voltage (120, 277 or 347).
170
2 SE NSE ™
Watts/Sq. ft.
ft.
Watts/Sq. ft.
•
•
•
•
•
Controls any DALI protocol ballast (no dimming controls required)
Footcandle Range: Application specific, consult factory.
Wall dimming controls not required, works with simple on/off switch
Commissioning not required
Passive Infrared (PIR) Occupancy sensor with 2 settings (toggle on sensor):
Setting 1: Open Office Mode – steps lighting down to 50% after 15 minute of inactivity
Setting 2: Private Office Mode – shuts lighting completely off after 15 minutes of inactivity.
• Recommended for use in small private offices and conference rooms with windows
• Maximum recommended mounting height: 10’
• Available with all Corelite D/I Extrusion families
SMART
ENVIRONMENTS
The energy saving 2Sense system
provides a combination of daylight
and occupancy sensing technology
(PIR) into one petite in-fixture sensor.
2Sense’s daylight sensor automatically
dims the luminaire when daylight is
detected, while its occupancy sensor
will shut-off the luminaire if human
body heat has not been detected for
15 minutes.
How to order:
L2-WM-2T5-1D-120-AC48-T1-12-2S
Note: 2Sense (2S) must be specified with Dimming (D) and specific voltage (120, 277 or 347).
171
SM ART E N VI RONME NT S
I N C LA SS C OMMA N D
A comprehensive turnkey lighting and control package that places the teacher in
command of the classrooom and the environment.
172
Teacher Lighting Controls:
Energy Saving Technology
Integration of lighting and controls into
one package, with command at the
teacher’s fingertips, could very well be the
teacher’s new best friend. Ensuring that
lighting is task appropriate – from ambient
illumination for reading to whiteboard
or media presentations – is crucial to
a productive atmosphere, and is easily
achieved with any of several customizable
switch interfaces. These controls
seamlessly combine the desired lighting
scenarios, making an attentive audience
just a switch-flip away.
In addition to the benefits of user control,
InClass Command employs occupancy and
daylight sensors to ensure that the lighting
system is as energy efficient as possible.
When daylight is present, the lighting dims
down. When students and teacher are no
longer present, the lighting shuts off. It’s
simple, smart and in command of true
energy savings.
General Illumination
A/V Mode
Creating an inviting and efficient atmosphere conducive to learning is of the utmost concern
when lighting for classrooms, and the needs of the instructor and the student must both
be considered. For the instructor, whiteboard visibility and the ability to adjust lighting for
multimedia presentations are critical. Students require efficient and controlled task lighting
for note taking and unimpeded computer screen visibility. Direct-Indirect suspended
luminaires, with their highly efficient bilateral ambient light distribution and isolatable
downlight components, address all of these requirements. The ability to easily integrate
energy-saving control systems only serves to further their appeal.
SMART
ENVIRONMENTS
Lighting The Classroom
173
SM ART E N VI RONME NT S
I N C LA SS C OMMA N D
(Surface Mount)
174
Corelite’s D/I Extrusion families supply
direct-indirect light distribution, offering
the ideal combination of functional direct
work surface illumination and indirect
ambient lighting for visual comfort. The
combination of lamp distribution isolators
and energy saving teacher controls truly
gives the teacher command of the class
and the classroom.
2. Daylight Sensor
An innovative energy-saving device,
the Day-Sense sensor can detect a
specific user-defined daylight level in a
space, and in turn automatically dim the
luminaire down. When used properly in
environments having sufficient daylight,
an energy savings of at least 35% can
be achieved.
3. Occupancy Sensor
Corelite’s Dual Technology surface
mount occupancy sensor’s combination
of Ultrasonic and Passive Infrared
technologies offers the most complete
sensing equipment available today.
This pairing helps eliminate false
activations or deactivations for additional
energy savings. The OMC-DT sensors are
also equipped with MicroSet technology,
which provides a revolutionary adaptive
and airflow tolerant technology, making
them ideal for spaces with increased
airflow due to higher occupant levels.
MicroSet Dual Tech sensors radically
simplify and reduce a contractor’s
installation and adjustment time period.
4. Teacher Lighting Controls
A decorator style switch with up
to five buttons offers ON/OFF
control of relay groups with the
touch of a button. The switch also
provides scene control and raise/
lower control of lighting loads
when used in conjuction with the
relay panel.
5. Relay Panel
Corelite’s lighting control panel
is a cost effective specification
grade lighting control system
packed with plenty of standard
features. Control up to 4 relays
per panel with optional support
for up to 4 0-10V dimming ballast
control outputs. Network up to 254
ControlKeeper panels for a state of
the art lighting control system.
6. Recessed Whiteboard Luminaire
When ambient lighting
alone cannot adequately
provide the necessary
vertical footcandles, wallwashing luminaires such
as the Neoray Series 23
may supplement the
lighting package to supply
the enhanced vertical
surface illumination
required for perfect
visibility of whiteboards.
SMART
ENVIRONMENTS
1. Suspended Luminaires
175
Corelite
4675 Holly Street
Denver, CO 80216
P: 303-393-1522
F: 303-393-1477
International Sales, USA
Cooper Lighting
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
F: 770-486-4801
Cooper Lighting
Customer First Center
1121 Highway 74 South
Peachtree City, GA 30269
Canada
Cooper Lighting
5925 McLaughlin Road
Mississauga, Ontario L5R 1B8
P: 770-486-4800
F: 770-486-4801
P: 905-507-4000
F: 905-568-7049
www.cooperlighting.com
Domestic Facilities
Cranbury, New Jersey
Elk Grove Village, Illinois
Irving, Texas
Ontario, California
Peachtree City, Georgia
The Cooper Lighting Family
Halo
Metalux
Lumark
Sure-Lites
Neo-Ray
Corelite
Portfolio
Iris
Shaper
io
Lumière
Invue
McGraw-Edison
Streetworks
Fail-Safe
PDS
MWS
RSA
Ametrix
Canadian Facilities
Calgary, Alberta T2E 7V9
Mississauga, Ontario L5R 1B8
Cooper Lighting and Corelite logos are valuable trademarks off Cooper Industries in the United States and other countries.
You are not permitted to use the Cooper Trademarks without the prior written consent off Cooper Industries.
Cooper Industries, Ltd.
600 Travis, Ste. 5800
Houston, TX 77002-1001
P: 713-209-8400
www.cooperindustries.com
ADE090950
Printed in USA
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : XDay Create Date : 2009:05:28 12:38:15-06:00 Modify Date : 2009:08:25 09:16:10-06:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2009:08:25 09:16:10-06:00 Creator Tool : Acrobat: pictwpstops filter 1.0 Document ID : uuid:6E4755DE37E211DE839C9132FE0B8FC0 Instance ID : uuid:334b9691-a5e1-4437-bd37-798b5fbc42e3 Derived From Instance ID : uuid:f0ff524e-3673-11de-93af-0017f208cae6 Derived From Document ID : uuid:168766d5-b4c1-4cfb-8923-718124664085 Format : application/pdf Creator : XDay Title : CoreliteCatalog Producer : Acrobat Distiller 9.0.0 (Windows) Page Count : 176EXIF Metadata provided by EXIF.tools