638059 Catalog

26099-Catalog 26099-Catalog 26099-Catalog 622454 Batch7 unilog cesco-content

2014-09-04

: Pdf 638059-Catalog 638059-Catalog 622454 Batch7 unilog

Open the PDF directly: View PDF PDF.
Page Count: 57

Download638059-Catalog
Open PDF In BrowserView PDF
CUSTOMER SERVICE CENTER
Customers call IPEX USA LLC
Toll free: (800) 463-9572
www.ipexamerica.com

About the IPEX Group of Companies
As leading suppliers of thermoplastic piping systems, the IPEX Group of
Companies provides our customers with some of the world’s largest and most
comprehensive product lines. All IPEX products are backed by more than
50 years of experience. With state-of-the-art manufacturing facilities and
distribution centers across North America, we have established a reputation
for product innovation, quality, end-user focus and performance.
Markets served by IPEX group products are:
• Electrical systems
• PVC, CPVC, PP, PVCO, ABS, PEX, FR-PVDF and PE pipe and fittings (1/4"
to 48")
• Industrial process piping systems
• Municipal pressure and gravity piping systems
• Plumbing and mechanical piping systems
• PE Electrofusion systems for gas and water
• Industrial, plumbing and electrical cements
• Irrigation systems

Products manufactured by IPEX Electrical Inc. and distributed in the United
States by IPEX USA LLC.
INEXO®, Kwikflex®, Kwikon®, SceptaConTM, SceptalightTM and SuperDuct® are
trademarks of IPEX Branding Inc.

Pocket Pro

DISTRIBUTED BY:

w w w . i p e x a m e r i c a . c o m

E L E C T R I C A L

This literature is published in good faith and is believed to be reliable.
However, it does not represent and/or warrant in any manner the
information and suggestions contained in this brochure. Data presented is
the result of laboratory tests and field experience.

S Y S T E M S

®

TM

TM

Trenchless Raceways Systems

A policy of ongoing product improvement is maintained. This may result
in modifications of features and/or specifications without notice.
®

®

®

®

CTELNAIP130709 © 2013 IPEX EL004U

w w w. i p ex a m e r i c a . c o m

TYPE
DESIGNATION

1

1
2

UL UNDERWRITERS LABORATORIES INC
(UL 50 AND UL 508)
Indoor use primarily to provide protection
against contact with the enclosed equipment
and against a limited amount of falling dirt.

Register your Pocket Pro today!
Fax this form to (905) 403-1124 and we’ll add
you to our mailing list.

Indoor use to provide a degree of protection
against limited amounts of falling water and dirt.

2

3

Outdoor use to provide a degree of protection
against windblown rain; undamaged by the
formation of ice on the enclosure.

4

Either indoor or outdoor use to provide a
degree of protection against falling rain,
splashing water, and hose-directed water;
undamaged by the formation of ice on the
enclosure.

4X

Either indoor or outdoor use to provide a
degree of protection against falling rain,
splashing water, and hose-directed water;
undamaged by the formation of ice on the
enclosure; resists corrosion.

Tel: (905) 403-0264
Toll Free: (800) 463-9572
Fax: (905) 403-1124

IPEX
2441 Royal Windsor Drive
Mississauga, Ontario, Canada
L5J 4C7

Website: www.ipexamerica.com
PLEASE PRINT

Company

3

Name

4

6P
5

12
13

Indoor or outdoor use primarily to provide a
degree of protection against hose-directed
water, the entry of water during prolonged
submersion at a limited depth, and be
undamaged by the formation of ice on the
enclosure.
Indoor use to provide a degree of protection
against dust, dirt, fiber flyings, dripping water,
and external condensation of noncorrosive
liquids.
Indoor use to provide a degree of protection
and spraying of water, oil, and noncorrosive
liquids.

6
This material is reproduced with permission from Underwriters
Laboratories Inc. Standard for Safety for Cabinets and Boxes, UL
50, Copyright 1988 and Industrial Control Equipment, UL 508,
Copyright 1994 by Underwriters Laboratories Inc.

7

Underwriters Laboratories Inc. (UL) shall not be responsible to
anyone for the use of or reliance upon a UL Standard by anyone.
UL shall not incur any obligation or liability for damages,
including consequential damages, arising out of or in connection
with the use, interpretation of, or reliance upon a UL Standard.

Title
Address
City

State

Zip

Phone

ext.

Fax

E-mail / Website

This is a:
❏ Home Address

❏ Business Address

❏ Jobsite Address

Business Type:
(check 1 or 2 that best apply)

Company Classification:
❏ Distributor/Wholesaler
❏ Engineering Firm
❏ Contractor
❏ Government
❏ OEM - Products Manufactured:_______________________
❏ Other:_____________________________________________
SIC or industry sector:__________________________________
My primary markets are (check all that apply):

8

❏ Commercial
❏ Residential
❏ Industrial
❏ Other:_________________

❏ Utility
❏ OEM
❏ Institutional

i

TABLE OF CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . .1
Applications . . . . . . . . . . . . . . . . . . . . . . . . .2
Advantages . . . . . . . . . . . . . . . . . . . . . . . . . .3
Scepter® Rigid PVC Schedule 40 & 80 Conduit .7
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Expansion and Contraction . . . . . . . . . . . . . . . . . .10
Conduit Dimensions . . . . . . . . . . . . . . . . . . . . . . .15

Scepter® PVC Conduit Fittings . . . . . . . . . . . .19
Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Cover Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Weatherproof Covers . . . . . . . . . . . . . . . . . . . . . . .46
Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55

Conduit Repair Kit . . . . . . . . . . . . . . . . . . . . .57
EPR Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57

SceptalightTM: Nonmetallic Light Fixtures . . . .59
Kwikflex® . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Nonmetallic Liquidtight Flexible Conduit . . . . . . . .67
Nonmetallic Liquidtight Fittings . . . . . . . . . . . . . . .68

Kwikon® ENT . . . . . . . . . . . . . . . . . . . . . . . . .71
ENT Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
Couplings/Connectors . . . . . . . . . . . . . . . . . . . . . .75
Slab Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
ENT Wall Boxes, Ceiling Boxes & Covers . . . . . . . . .81
Short Form Sample Specifications . . . . . . . . . . . . .82

INEXO® ICF Boxes . . . . . . . . . . . . . . . . . . . . .85
....continued

ii

TABLE OF CONTENTS

INTRODUCTION

Super Duct® . . . . . . . . . . . . . . . . . . . . . . . . .87
Advantages . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
Engineering Data . . . . . . . . . . . . . . . . . . . . . . . . .89
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91
Telephone Duct . . . . . . . . . . . . . . . . . . . . . . . . . .94
Power & Communication Duct . . . . . . . . . . . . . . . .95

SceptaconTM Trenchless Raceway Systems . . .97

Pocket Pro provides the most comprehensive information about
PVC systems – from basic raw material to installation
characteristics of the finished product. Written with the engineer,
contractor and distributor in mind, it is based on laboratory test
results and IPEX’s many years of field experience.
At IPEX, we have been extruding PVC conduit and molding
fittings since 1951. We formulate our own compounds,
maintain strict quality control during production, and offer one
of the most comprehensive lines of nonmetallic electrical
products throughout North America.
More important, our commitment to customers extends
beyond the sale. Quality control and thorough jobsite field
reports have earned IPEX a reputation for product quality and
service excellence.

1

2

APPLICATIONS

Engineers, electricians, contractors, specifiers and utilities have
realized for many years the advantages of PVC. Today, IPEX
electrical systems include Scepter® PVC conduit and fittings,
INEXO® ICF boxes, Kwikon® ENT fittings, SceptaConTM
trenchless raceway systems, SceptalightTM nonmetallic light
fixtures and Super Duct® power and communication ducts.
These brands are the number-one choice for power,
communication and data needs. Whether exposed, concealed in
walls, encased in concrete, or directly buried, IPEX electrical
products are preferred For The Long Run.
Only when you specify IPEX branded products by name are you
guaranteed our commitment to excellence.

3

ADVANTAGES

Labor Savings
Compared to metal, PVC products reduce labor on a typical
installation by up to two-thirds. The reason?
PVC is easy to work with. It can also be cut and joined without
vises, cutters, threading equipment and reamers associated
with metal conduit.

Lightweight Conduit
Scepter rigid PVC conduit is one-half the weight of aluminum
and one-sixth the weight of steel. As a result, handling and
installation are easier and faster, reducing labor costs.

Applications

Easy Joining

Typical industrial/commercial and residential applications for
IPEX electrical systems include:

Solvent cementing is all that is required, eliminating the need
for power-threading machines, pipe vises and cutting
equipment. A hacksaw or carpenter’s saw is the only
equipment required.

• Mines
• Steel mills
• Food processing plants

Strength

• Subways

Scepter rigid PVC conduit offers both high impact and high
tensile strength, even in cold temperatures. They exceed all UL
and NEMA standards.

• Bridges and tunnels
• Agricultural, dairy, hog, cattle,
chicken, etc.
• Marinas

Rigid Conduit Sch. 40
Size (in.)

UL Impact @ 73°F
(ft.lbs.)

1/2

50

• Sewage treatment plants

3/4

80

• Pulp & paper industries

1

100

1-1/4

120

1-1/2

150

2

190

• Parking garages

2-1/2

210

• Residential applications

3–6

220

• Street and highway lighting
• Car washes

• Fish plants
• Water treatment plants
• Airports
• Utilities
• Cable
• Communications

4

ADVANTAGES

5

ADVANTAGES

Easy Wire Pulls

Fire Resistant

PVC’s exceptionally smooth interior surface greatly reduces the
amount of friction while pulling conductors/wires through long
runs, even with 90° bends. A large pull-rope and wire-pulling
compound should be used when pulling all conductors and wires.

PVC is a self-extinguishing material and will not support
combustion. It will not drip or run when exposed to fire.

Noncorroding

The interior of the conduit, however, was unaffected.
Additionally, the undamaged conductors were then removed
and reinstalled in new conduit.

PVC is immune to damage from naturally
corrosive soil conditions, as well as
electro-chemical and galvanic corrosion.
This ensures lower maintenance costs and
longer performance For The Long Run.

Samples taken from an actual fire show the outer surface of
the conduit was blistered and charred.

Fire-resistant characteristics per CAN ULC S102.2 are as follows:
IPEX
Compound

Flame
Spread

Smoke
Developed

Fuel
Contribution

Nonconducting

1/8" thickness

10 – 20

225 – 270

0

IPEX electrical systems are nonsparking
and non-conducting, thereby eliminating
the most dangerous ‘second point of
contact’ and ‘phase to ground’ faults. The
use of a separate grounding conductor
provides complete and positive grounding
for the whole system.

3/4" thickness

10 – 20

300 – 390

0

Long Life
Scepter rigid PVC conduit and fittings
retain their original properties after years
of exposure to direct sunlight, heat and
weather. In addition, resistance to fungi,
bacterial action, rodents, termites and
corrosive agents ensures a long, troublefree life for PVC conduit installed indoors
or outdoors.

Suitable for Direct Burial
PVC is suitable for direct burial and
requires no extra protection when installed
in accordance with local inspection
authority guidelines. The usual care
regarding trenches and backfilling should
be respected.

One-Source Specification
IPEX electrical systems offer a full range
of PVC fittings and accessories. As a
result, one-material specifying is possible.

Quality Control
Chemical Resistance
One of the greatest benefits of PVC is its
excellent chemical resistance. It resists
attack by acids, alkalies, salt solutions
and many other types of chemicals.
For more information on PVC and
chemical resistance, refer to the IPEX
Chemical Resistance Guide.

Concrete Tight
Scepter rigid PVC conduit systems are designed and engineered to
be concrete tight in all weather conditions.

In addition to our rigorous quality control
testing, IPEX product carries third-party
certification by UL and CSA.

Bookmark Our Website

SCEPTER RIGID PVC SCH. 40 & 80 CONDUIT

SCEPTER RIGID
PVC CONDUIT

www.ipexamerica.com

PRODUCT INFO,
TECHNICAL
DOCUMENTS,
ONLINE TRAINING
& MUCH MORE ...

This section provides comprehensive information and
guidelines for the design and installation of PVC Schedule 40
& 80 conduit and fittings. Always consult the authority having
jurisdiction for specific installation procedures.

OUR ELECTRICAL CATALOG
& SCEPTER ELECTRICAL
CATALOG INCLUDE MORE
INFORMATION ON:
• Conduit & Fittings
• Light Fixtures

• Duct
• Trenchless Raceways

• ENT Tubing & Fittings

• and much more

...

available at w w w. i p e x a m e r i c a . c o m

7

UL Listed-UL651
Sunlight Resistant
Rated for use with 90°C
conductors

NEMA TC-2
Corps. of Engineers Spec.
CE 303:01
Military Spec,Federal Spec.
WC 09A

INSTALLATION

INSTALLATION

Support

Solvent Cementing

Due to PVC’s light weight,
support spacing is different
than that used with metal
conduits. Supporting straps should
NOT be firmly tightened, to allow for
linear movement. The maximum
allowable support spacing, as per National Electrical
Code Article 352.30 (NEC), is as follows:

After cutting Scepter rigid PVC conduit,
sharp edges or burrs from inside the
conduit should be removed with a knife.
Thoroughly clean the end of the pipe
and inside the fitting with a pipe
cleaner. Apply a generous amount of
solvent cement to both surfaces; slide
together and give a quarter turn to
ensure the solvent is spread evenly on
the material. Hold together for a few
seconds until the joint is made.

Support Spacing For Schedule 40 & 80
Conduit
Nominal Conduit Diameter
inches

Maximum Support Spacing
feet

1/2

3

3/4

3

1

3

1-1/4

5

1-1/2

5

2

5

2-1/2

6

3

6

3-1/2

7

4

7

5

7

6

8

Maximum Operating
Temperature
The National Electrical Code (NEC)
permits the use of rigid PVC pipe and
fittings in areas where ambient
temperatures do not exceed 122°F.

Cutting
Scepter rigid PVC conduit can be easily
cut on the jobsite by using a hacksaw,
carpenter’s saw or PVC conduit cutters.
For larger sizes of conduit, the use of a
miter box is also recommended to ensure
a square cut.

Usually the solvent-cemented joint will
be strong enough to install immediately.
However, in climates with low
temperatures or areas with high humidity, extra time may be
required before moving the pipe for permanent installation.
Solvent cemented joints appear to “set up” instantly, but will
take 24 hours to cure properly. After this time, the solventcemented joint has completely cured and is waterproof. For
extreme cold weather installations, a PVC primer is
recommended. IPEX cements and primers are available in
quarter-pint, half-pint, pint, quart and gallon containers.

Bending
PVC is a thermoplastic material that,
when heated, becomes soft and pliable.
As a result, its shape can be altered.
A flameless heat source is
recommended to heat the pipe. AN
OPEN FLAME SHOULD NOT BE USED.
Either an electric unit or an infra-red
propane unit is recommended.
The necessary temperature for bending
pipe is 260°F. The pipe must be heated
evenly over an area approximately ten
times the diameter of the pipe before
any attempt at bending is made.
Bending the pipe when it has not been
thoroughly heated will cause the pipe to
“kink.” With proper care and a little
practice, the bend will form easily.
Cooling the pipe with cold air or water
will cause “spring back.” Allow a few
extra degrees of overbending to
compensate. Maximum bending radius
shall be six times the internal diameter
according to NEC.

9

SCEPTER RIGID
PVC CONDUIT

SCEPTER RIGID
PVC CONDUIT

8

11

EXPANSION & CONTRACTION

EXPANSION & CONTRACTION

Using Expansion Joints

Number of Expansion Joints Required

It’s just as important to know when to
use an expansion joint as it is to know
how to install it correctly. Expansion
joints are required when the
temperature change is greater than
25°F. Scepter rigid PVC conduit has a
coefficient of linear expansion of 3.6 x
10-4 in./ft./°F. Generally, a 100 ft. run
of PVC conduit will undergo a change in
length of 3.6 inches for every 100°F
temperature change.

Use the following equation to determine the number of expansion
joints needed for a Scepter Rigid PVC Conduit installation:
total expansion (in)

Number of joints =

E
E = Expansion joint travel length (4") or (8") depending on diameter.
Always round up to the next whole number.

Setting the Piston Opening

For conduit installed indoors, the range of expansion and
contraction can be calculated using the maximum air
temperature plus the heat contributed by the conductors inside
the conduit and minimum air temperature expected. Expansion
joints are not required indoors unless there are widely varying
temperatures such as the attic of a building.
Conduit installed outdoors, exposed to direct sunlight, will be
considerably hotter than the air temperature. As a guideline in
this case, add 27°F to the temperature change. Expansion
joints should be installed to allow for the anticipated
temperature change.

Expansion Formula

The expansion joint must be installed to allow for expansion and
contraction of the conduit run. On a cold day, if an expansion joint is
installed completely closed with the piston bottomed, there is no room
for expansion when the conduit is warmed. If it is installed open to the
maximum on a hot day, the expansion joint will pull apart when cooled.
The correct piston opening for any installation condition can be easily
determined using the formula below:
Piston setting =
Compressed length +

(

max. temp. – installation temp.
max. temp. – min. temp.

)

xE

Formula can be used for both metric and imperial measurements.

By using the following formula and the chart below, the total
expected expansion in a run can be easily determined:
Total Expansion (in.) = length of run (ft.)
x temperature change (°F) x 0.00036
PVC PIPE LENGTH VARIATION
DUE TO TEMPERATURE CHANGE (ºF)
Coefficient = 3.6 x 10-4 in/ft/ºF

TEMPERATURE CHANGE IN ºF

120
110
100
90
80

PVC PIPE

70
60
50
40
30
20
10
0

As a general rule
for every
temperature
change of 10ºF,
PVC pipe will
expand or contract
3/8" per 100'
1
2
3
4
LENGTH VARIATION in/100 ft OF PIPE

5

Size (inches)

Compressed Length (inches)

Travel (inches)

1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
5
6

8.00
8.00
8.50
9.00
9.00
9.25
9.25
14.25
14.25
14.25
14.25
14.25

4
4
4
4
4
4
4
8
8
8
8
8

SCEPTER RIGID
PVC CONDUIT

SCEPTER RIGID
PVC CONDUIT

10

EXPANSION & CONTRACTION

EXPANSION & CONTRACTION

Location of Expansion Joints

Figure 1

Proper functioning of an expansion joint depends on three
procedures:
1. The correct placement of the expansion joint.
2. The proper installation of Scepter rigid PVC conduit and the
expansion joint.
3. The proper placement and fastening of support straps.

One Expansion Joint
Figure 1
If only one expansion joint is needed between two boxes, the
barrel of the joint should be rigidly fastened close to the
first box. Scepter rigid PVC conduit is then loosely supported
with straps, allowing the conduit to move freely as it
expands and contracts.

Figure 2

Two Expansion
Joints
Figure 2
If two expansion joints
are needed, the joints are
firmly fastened back to back
at the center of the run.
Scepter rigid PVC conduit is
loosely supported with straps, allowing the
conduit to move freely as it expands and
contracts.

Figure 3

Two Expansion Joints (Alternative)
Figure 3
Alternatively, the center of the run and the two expansion joints
(located at the boxes) should be rigidly fastened. All other
support straps should be loosely fastened.

Three or More Expansion Joints
Figure 4
If more than two joints are needed in a very long run, they
should be put in a series, one after the other. Each barrel must
be rigidly fastened while conduit is loosely supported with
straps allowing conduit to move freely as it expands and
contracts. When installed in a series, each section acts
independently of the other. Spacing of conduit supports must
be in accordance with the NEC Article 352.30.

13

SCEPTER RIGID
PVC CONDUIT

SCEPTER RIGID
PVC CONDUIT

12

Figure 4

15

CONDUIT DIMENSIONS

EXPANSION & CONTRACTION

Installation of Expansion Joints

Scepter PVC Schedule 40 in 10' or 20' Lengths

Installation recommendations:

Scepter PVC Schedule 40 conduit is listed with Underwriters
Laboratories Inc. Article 352 of the National Electrical Code
outlines the correct installation procedures.

• Expansion joints should be mounted so the piston can
travel in a straight line in the barrel. If the alignment is not
straight, the piston will bind, preventing the joint from
working correctly.
• The expansion joint barrel should be clamped tight, but the
conduit mounted loose enough in its hangers to allow for
movement as it expands and contracts.
• Scepter nonmetallic straps are correctly sized and designed
for proper support, and must be used to secure the conduit.
• When expansion joints are used in a vertical position, the
piston should be in a downward position so dirt cannot
deposit between the barrel and piston at the muzzle of the
expansion joints.

WARNING:
Common Mistakes
The most common mistakes are neglecting to use
expansion joints or not using enough expansion joints. It
is more cost effective to use more expansion joints than
needed, rather than too few. It is difficult to correct the
problem after conductors are installed and in service.
Another common mistake is to tighten the support straps
too firmly. This will not allow for the proper expansion and
contraction of rigid PVC conduit.

Installation of the One Piece
Expansion Joint (OPEJ)
1. Solvent cement the PVC conduit into the conduit hub of
the OPEJ and firmly secure the PVC conduit on the
solvent cement side of the OPEJ using IPEX pipe straps.
2. Set the expansion fitting by marking a line 11/2" from the
end of the conduit to be inserted and insert the conduit
into the OPEJ to this mark.
3. Secure and support the conduit raceway using IPEX
pipe straps.

Nominal 10'
20'
Code ID (in)
Size Product Product OD
(in)
(in)
Code Code

Min. Weight Standard
Wall lbs/100 10'
(in)
ft
ft/crate

1/2

032405 032406 0.840 0.622 0.109

15

6,000

3/4

032407 032408 1.050 0.824 0.113

21

4,400

1

032410 032411 1.315 1.049 0.133

31

3,600

1-1/4 032412 032414 1.660 1.380 0.140

42

3,300

1-1/2 032415 032416 1.900 1.610 0.145

53

2,250

71

1,400

112

930

032430 032431 3.500 3.068 0.216

166

880

3-1/2 032435 032436 4.000 3.548 0.226

200

630

2

032420 032421 2.375 2.067 0.154

2-1/2 032425 032426 2.875 2.469 0.203
3
4

032440 032441 4.500 4.026 0.237

236

570

5

032450 032451 5.563 5.047 0.258

321

380

6

032460 032461 6.625 6.065 0.280

417

260

Weight Comparison of Scepter Rigid PVC
Conduit (lbs./100 ft.)
Nominal Size (in)

Schedule 40 PVC

Aluminum

Rigid Steel

1/2

15

28

79

3/4

21

36

105

1

31

53

153

1-1/4

42

70

201

1-1/2

53

86

249

2

71

116

334

2-1/2

112

183

527

3

166

239

690

3-1/2

200

288

831

4

236

340

982

5

321

465

1,334

6

417

613

1,771

UL Listed-UL651
Sunlight Resistant
Rated for use with 90°C
conductors

NEMA TC-2
Corps. of Engineers Spec.
CE 303:01
Military Spec, Federal Spec.
WC 1094A

SCEPTER RIGID
PVC CONDUIT

SCEPTER RIGID
PVC CONDUIT

14

Scepter Schedule 80 Heavy Wall in 10' or
20' Lengths
Scepter PVC Heavy Wall conduit is for use above and below
ground where it may be subject to severe physical damage, such
as pole risers, bridge crossings and other similar applications.
20'
Nominal 10' Product
OD (in) ID (in)
Size (in) Product
Code Code

Min.
Wall
(in)

Weight Standard
lbs/100 10'
ft
ft/crate

1/2

032505 032506 0.840

0.546

0.147

21

6,000

3/4

032507 032508 1.050

0.724

0.154

28

4,400

1

032510 032511 1.315

0.957

0.179

41

3,600

1-1/4 032512 032514 1.660

1.278

0.191

57

3,300

1-1/2 032515 032516 1.900

1.500

0.200

70

2,250

032520 032521 2.375

1.939

0.218

96

1,400

2-1/2 032525 032526 2.875

2.323

0.276

146

930

2

17

CONDUIT DIMENSIONS

CONDUIT DIMENSIONS

PHYSICAL PROPERTIES OF PVC TYPE II

UNIT

VALUE

ASTM
TEST
METHOD

Dielectric Strength

volts/mil

1215

D149

Dielectric Constant

60 cps at 30ºC
1000 cps at
30ºC

3.55

D150

3.22

D150

Power Factor

60 cps at 30ºC
1000 cps at
30ºC

4.04

D150

4.71

D150

13.5

D792

PROPERTIES

ELECTRICAL

PHYSICAL

3

032530 032531 3.500

2.900

0.300

195

880

Specific Gravity

4

032540 032541 4.500

3.826

0.337

286

570

Hardness

Durometer D

78

D676

5

032550 032551 5.563

4.813

0.375

397

380

6

032560 032561 6.625

5.761

0.432

546

260

Izod Impact Strength
@ 73ºF (23ºC)

ft.lb/in. notch

15.0

D256

Tensile Strength
@ 73ºF (23ºC)

psi

6000

D638

Compressive Strength

psi

8600

D695

Flexural Strength

psi

11500

D790

BTU/sec/in2/ºF/in

0.11

C177

per ºF x 10-5

5.5

D696

ºF

158

D648

selfextinguishing

D635

Weight Comparison of Scepter Rigid PVC
Conduit (lbs./100 ft.)
Nominal Size (in)

Schedule 80 PVC

Aluminum

Rigid Steel

1/2

21

28

79

3/4

28

36

105

1

41

53

153

1 1/4

57

70

201

1 1/2

70

86

249

2

96

116

334

2 1/2

146

183

527

3

195

239

690

4

286

340

982

5

397

466

1,334

6

546

613

1,771

THERMAL
Coefficient of Thermal
Conductivity
Coefficient of Linear
Expansion
Heat Distortion
Temperature at 264 psi
OTHERS
Flammability
Water Absorption in 30
days
Color
Light Transmission

UL Listed-UL651
Sunlight Resistant
Rated for use with 90°C
conductors

NEMA TC2
Corps. of Engineers Spec.
CE 303:01
Military Spec, Federal Spec.
WC 1094A

%

0.6
charcoal grey
opaque

D791

All technical data is believed to be accurate and is presented soley
for information and guidance.

SCEPTER RIGID
PVC CONDUIT

SCEPTER RIGID
PVC CONDUIT

16

NOTES

19

SCEPTER CONDUIT
FITTINGS

____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________

PVC CONDUIT FITTINGS

Industry leaders specify Scepter PVC conduit fittings by
name. For years, Scepter PVC fittings have set the standard
for quality and value-added features not normally available
from other suppliers. Features such as our threaded brass
inserts, brass screws and superior PVC gasketing system
make a real difference.

It’s our Commitment to Excellence.

UL Listed
UL514B - UL514C

NEMA TC-2, 3

C22.2 No. 85

UL651

20

Long Line Couplings

Size (in)

Part
Number

Product
Code

A (in)

B (in)

C (in)

1/2

EC10

068000

1.060

0.844

1.400

EC15

068001

1.310

1.056

Size (inches)

Part Number

Product Code

A (inches)

1-1/2

LLC30

077192

3.175

2

LLC35

077193

3.675

2-1/2

LLC40

077194

4.280

3

LLC45

077195

4.800

4

LLC55

077196

6.200

5

LLC60

077197

8.220

6

LLC65

077198

8.220

1.640

1

EC20

077003

1.590

1.315

2.031

1-1/4

EC25

077004

2.000

1.660

2.156

1-1/2

EC30

077005

2.230

1.900

2.281

2

EC35

077006

2.720

2.375

2.406

2-1/2

EC40

077007

3.320

2.875

3.187

3

EC45

077008

4.000

3.500

3.437

3-1/2

EC50

077009

4.500

4.000

3.625

4

EC55

077010

5.000

4.500

3.750

5

EC60

077011

6.120

5.563

4.187

6

EC65

077012

7.370

6.625

4.562

Fabricated Swedge Reducer Couplings
(Socket x Socket) Other sizes available upon request.

5º couplings
Size (inches)

Part Number

Product Code

L (inches)

2

5EC35

077100

4.0

2-1/2

5EC40

077101

5.5

3

5EC45

077103

6.0

3-1/2

5EC50

077102

7.0

4

5EC55

077104

7.0

5

5EC60

077105

7.5

6

5EC65

077106

11.0

Size (inches)

Part Number

Product Code

L (inches)

2 x 1-1/4

SW3525

077320

4

3x2

SW4535

077321

6

3 x 2-1/2

SW4540

077335

6.5
7

4x2

SW5535

077322

4 x 2-1/2

SW5540

069282

-

4x3

SW5545

077333

7

D

Repair Coupling Sleeve

A

Size
(inches)

Part
Number

Product A (inches) D Min
Code
(inches)

D Max
(inches)

1-1/2

REC30

077292

2.300

1.912

2

REC35

077293

2.405

2.367

2.399

2-1/2

REC40

077294

3.450

2.883

2.897

1.924

3

REC45

077295

3.600

3.507

3.523

4

REC55

077296

3.920

4.506

4.524

5

REC60

077297

4.275

5.583

5.603

6

REC65

077298

4.620

6.647

6.669

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

Couplings

3/4

21

FITTINGS

FITTINGS

22

FITTINGS

Reducer Bushings
A (in)

B (in)

C (in)

D (in)

Size (in)

Part Number

Product Code

3/4 x 1/2

1805

077300

1 x 1/2

1805-1

077301

1 x 3/4

1806

077302

1-1/4 x 3/4

1807-1

077303

1/2

TA10

077021

0.700

0.591

0.750

1.550

3/4

TA15

077022

0.675

0.790

1.000

1.750

1

TA20

077023

0.625

1.000

1.115

1.860

1-1/4

TA25

077024

0.640

1.311

1.300

2.125

1-1/4 x 1

1807

077304

1-1/2

TA30

077025

0.725

1.530

1.425

2.250

1-1/2 x 1

1808-1

077305

2

TA35

077026

0.800

1.970

1.150

2.100

1-1/2 x 1-1/4

1808

077306

2-1/2

TA40

077027

0.800

2.346

1.900

2.930

2x1

1809-1

077313

3

TA45

077028

0.815

2.915

2.000

3.055

2 x 1-1/4

1809

077307

3-1/2

TA50

077029

1.000

3.385

1.715

3.055

2 x 1-1/2

1810

077308

4

TA55

077030

0.815

3.850

1.990

3.215

2-1/2 x 2

1811

077309

5

TA60

077031

1.725

5.015

2.000

5.985

3x2

1812-1

077310

6

TA65

077032

1.875

6.025

2.130

6.500

3 x 2-1/2

1812

077311

4x2

1813-1

077319

4x3

1813

077312

4 x 3-1/2

1814

077317

*Additional sizes of reducer bushings are available upon request.

Female Adapters
Part
Product
Size (in) Number
Code

A (in)

B (in)

C (in)

D (in)

1/2

FA10

076544

0.620

1.080

0.800

1.725

1/2

FA10

077041

0.620

1.080

0.800

1.725

3/4

FA15

077042

0.820

1.300

0.800

1.900

1

FA20

077043

1.065

1.590

1.000

2.300

1-1/4

FA25

077044

1.395

2.000

1.015

2.425

1-1/2

FA30

077045

1.575

2.230

1.050

2.440

2

FA35

077046

2.050

2.720

1.075

2.550

2-1/2

FA40

077047

1.020

3.250

1.500

2.700

3

FA45

077048

3.090

4.000

1.630

4.100

3-1/2

FA50

077049

3.540

4.500

1.800

3.895

4

FA55

077050

4.025

5.000

1.755

4.210

5

FA60

077051

5.035

6.120

2.065

5.240

6

FA65

077052

6.045

7.370

2.065

5.235

Note: All female adapters have NPT-tapered threads.
Note: 1/2" to 1 1/4" TA - tapered thread
1 1/2" to 6" TA - non-tapered thread

Threaded Reducer Bushings
Size (in)

Part Number

Product Code

3/4 x 1/2

1825

077314

1 x 1/2

1826

077315

1 x 3/4

1827

077316

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

Terminal Adapters
Part
Product
Size (in) Number
Code

23

FITTINGS

24

End Bells

Poly Plugs

Size (in)

Part Number

Product Code

Size (in)

Part Number

Product Code

1/2

EB-10

077406

2 - 2-1/2

PP3540

077433

3/4

EB-15

077085

3 - 3-1/2

PP4550

077434

1

EB-20

077323

4

PP55

077435

1-1/4

EB-25

077324

5

PP60

077436

1-1/2

EB-30

077325

6

PP65

077437

2

EB-35

077326

2-1/2

EB-40

077327

3

EB-45

077328

3-1/2

EB-50

077329

4

EB-55

077330

5

EB-60

077331

6

EB-65

077332

“O” Ring Expansion Joints

B
min.

A
max.

Size (in) Part Number

End Caps

Product Code

A (in)

B (in)

1/2

EJ10

077381

12.00

8.00

3/4

EJ15

077382

12.00

8.00

1

EJ20

077383

12.50

8.50

1-1/4

EJ25

077384

13.00

9.00

Size (in)

Part Number

Product Code

1-1/2

EJ30

077385

13.00

9.00

1/2

CAP10

077421

2

EJ35

077386

13.25

9.25

3/4

CAP15

077422

2-1/2

EJ40

077387

13.25

9.25

1

CAP20

077423

3

EJ45

077388

22.25

14.25

1-1/4

CAP25

077424

3-1/2

EJ50

077389

22.25

14.25

1-1/2

CAP30

077425

4

EJ55

077390

22.25

14.25

2

CAP35

077426

5

EJ60

077391

22.25

14.25

2-1/2

CAP40

077427

6

EJ65

077392

22.25

14.25

3

CAP45

077428

3-1/2

CAP50

077429

4

CAP55

077430

5

CAP60

077431

6

CAP65

077432

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

25

FITTINGS

FITTINGS

26

27

FITTINGS

FITTINGS

One Piece Expansion Joints
Part Number

Product Code

1/2

OPEJ10

077018

3/4

OPEJ15

077019

1

OPEJ20

077053

Size
inches

Part
Number

Product
Code

D
inches

T
inches

R
inches

1-1/4

OPEJ25

077054

1/2

EE1090

068580

0.840

1.500

4.00

1-1/2

OPEJ30

077061

3/4

EE1590

068581

1.050

1.500

4.50

2

OPEJ35

077063

1

EE2090

068582

1.315

1.875

5.75

1-1/4

EE2590

068583

1.660

2.000

7.25

1-1/2

EE3090

068584

1.900

2.000

8.25

2

EE3590

068585

2.375

2.000

9.50

2-1/2

EE4090

068586

2.875

3.000

10.50

SCEPTER CONDUIT
FITTINGS

Size (in)

T.A. Special Expansion Joint

Size (in)

Part Number

Product Code

2-1/2

EJ40TA

077398

Expansion and Deflection Fitting Assemblies

3

EE4590

068587

3.500

3.125

13.00

3-1/2

EE5090

068588

4.000

3.250

15.00

4

EE5590

068589

4.500

3.375

16.00

5

EE6090

068591

5.563

3.625

24.00

6

EE6590

068592

6.625

3.750

30.00

45° Elbows
Schedule 40
Standard Radius
Size
inches

Part
Number

Product
Code

D
inches

T
inches

R
inches

Size (in)

Part Number

Description

Product Code

1/2

EE1045

068600

0.840

1.500

4.00

2*

SE-J-35

Complete Assembly

077889

3/4

EE1545

068601

1.050

1.500

4.50

3*

SE-J-45

Complete Assembly

077890

1

EE2045

068602

1.315

1.875

5.75

4*

SE-J-55

Complete Assembly

077891

1-1/4

EE2545

068603

1.660

2.000

7.25

1-1/2

EE3045

068604

1.900

2.000

8.25

2

EE3545

068605

2.375

2.000

9.50

2-1/2

EE4045

068606

2.875

3.000

10.50

* Not Certified

3

EE4545

068607

3.500

3.125

13.00

3-1/2

EE5045

068608

4.000

3.250

15.00

4

EE5545

068609

4.500

3.375

16.00

5

EE6045

068611

5.563

3.625

24.00

6

EE6545

068612

6.625

3.750

30.00

SCEPTER CONDUIT
FITTINGS

90° Elbows
Schedule 40
Standard Radius

28

29

FITTINGS

30° Elbows
Schedule 40
Standard Radius

90° Elbows
Schedule 40
Integral Bell End

R

D

Size
inches

Part
Number

Product
Code

D
inches

T
inches

R
inches

Size
inches

1/2

EE1030

068620

0.840

1.500

4.00

3/4

EE1530

068621

1.050

1.500

4.50

1

EE2030

068622

1.315

1.875

1-1/4

EE2530

068623

1.660

1-1/2

EE3030

068624

2

EE3530

2-1/2

Part
Number

Product
Code

D
inches

T
inches

R
inches

1/2

EE1090B 068420

0.840

1.500

4.00

3/4

EE1590B 068421

1.050

1.500

4.50

5.75

1

EE2090B 068422

1.315

1.875

5.75

2.000

7.25

1-1/4

EE2590B 068423

1.660

2.000

7.25

1.900

2.000

8.25

1-1/2

EE3090B 068424

1.900

2.000

8.25

068625

2.375

2.000

9.50

2

EE3590B 068425

2.375

2.000

9.50

EE4030

068626

2.750

3.000

10.50

2-1/2

EE4090B 068426

2.875

3.000

10.50

EE4530

068627

3.500

3.125

13.00

3

EE4590B 068427

3.500

3.125

13.00

EE5030

068628

4.000

3.250

15.00

3-1/2

EE5090B 068428

4.000

3.250

15.00

4

EE5530

068629

4.500

3.375

16.00

4

EE5590B 068429

4.500

3.375

16.00

5

EE6030

068631

5.563

3.625

24.00

5

EE6090B 068430

5.563

3.625

24.00

6

EE6530

068632

6.625

3.750

30.00

6

EE6590B 068431

6.625

3.750

30.00

Product
Code

D
inches

T
inches

R
inches

T

3
3-1/2

22-1/2° Elbows
Schedule 40
Standard Radius

R

45° Elbows
Schedule 40
Integral Bell End

D

Size
inches

Part
Number

Product
Code

D
inches

T
inches

R
inches

Size
inches

1-1/2

EE1522

078580

1.900

2.000

8.25

1/2

EE1045B 068561

0.840

1.500

4.00

9.50

3/4

EE1545B 068562

1.050

1.500

4.50

10.50

1

EE2045B 068563

1.315

1.875

5.75

13.00

1-1/4

EE2545B 068564

1.660

2.000

7.25

EE3045B 068565

1.900

2.000

8.25

2
2-1/2
3

EE2022
EE2522
EE3022

078581
078582
078583

2.375
2.875
3.500

2.000
3.000
3.125

Part
Number

3-1/2

EE3522

078584

4.000

3.250

15.00

1-1/2

4

EE4022

078585

4.500

3.375

16.00

2

EE3545B 068566

2.375

2.000

9.50

5

EE5022

078586

5.563

3.625

24.00

2-1/2

EE4045B 068567

2.875

3.000

10.50

6

EE6022

078587

6.625

3.750

30.00

3

EE4545B 068568

3.500

3.125

13.00

3-1/2

EE5045B 068569

4.000

3.250

15.00

4

EE5545B 068570

4.500

3.375

16.00

5

EE6045B 068571

5.563

3.625

24.00

6

EE6545B 068572

6.625

3.750

30.00

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

T

FITTINGS

30

31

FITTINGS

90° Elbows
Schedule 80
Standard Radius

30° Elbows
Schedule 80
Standard Radius

R

D

Size
inches

Part
Number

Product
Code

D
inches

T
inches

R
inches

Size
inches

1/2

80EE1090 068690

0.840

1.500

4.00

3/4

80EE1590 068691

1.050

1.500

4.50

1

80EE2090 068692

1.315

1.875

1-1/4

80EE2590 068693

1.660

1-1/2

80EE3090 068694

2

Product
Code

D
inches

T
inches

R
inches

1/2

80EE1030 068550

0.840

1.500

4.00

3/4

80EE1530 068551

1.050

1.500

4.50

5.75

1

80EE2030 068552

1.315

1.875

5.75

2.000

7.25

1-1/4

80EE2530 068553

1.660

2.000

7.25

1.900

2.000

8.25

1-1/2

80EE3030 068554

1.900

2.000

8.25

80EE3590 068695

2.375

2.000

9.50

2

80EE3530 068555

2.375

2.000

9.50

2-1/2

80EE4090 068696

2.875

3.000

10.50

2-1/2

80EE4030 068556

2.750

3.000

10.50

3

80EE4590 068697

3.500

3.125

13.00

3

80EE4530 068557

3.500

3.125

13.00

4

80EE5590 068698

4.500

3.375

16.00

4

80EE5530 068558

4.500

3.375

16.00

5

80EE6090 068699

5.563

3.625

24.00

5

80EE6030 068559

5.563

3.625

24.00

6

80EE6590 068700

6.625

3.750

30.00

6

80EE6530 068560

6.625

3.750

30.00

Product
Code

D
inches

T
inches

R
inches

1/2

80EE1045 068810

0.840

1.500

4.00

3/4

80EE1545 068811

1.050

1.500

4.50

1

80EE2045 068812

1.315

1.875

5.75

1-1/4

80EE2545 068813

1.660

2.000

7.25

1-1/2

80EE3045 068814

1.900

2.000

8.25

2

80EE3545 068815

2.375

2.000

9.50

2-1/2

80EE4045 068816

2.875

3.000

10.50

3

80EE4545 068817

3.500

3.125

13.00

4

80EE5545 068818

4.500

3.375

16.00

5

80EE6045 068819

5.563

3.625

24.00

6

80EE6545 068820

6.625

3.750

30.00

45° Elbows
Schedule 80
Standard Radius
Size
inches

Part
Number

Part
Number

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

T

FITTINGS

32

33

FITTINGS

FITTINGS

Schedule 40 Special Radius (Plain End)

1

1-1/4

1-1/2

2

2-1/2

3

3-1/2

4

5

6

8

Degree Bend
90
45
30
22-1/2
90
45
30
22-1/2
90
45
30
22-1/2
90
45
30
22-1/2
90
45
30
22-1/2
90
45
30
22-1/2
90
45
30
22-1/2
90
45
30
22-1/2
90
45
30
22-1/2
90
45
30
22-1/2
90
45
22-1/2
11-1/4

18" Radius
Product Code

24" Radius
Product Code

30" Radius
Product Code

36" Radius
Product Code

48" Radius
Product Code

60" Radius
Product Code

068702
068802
068902
078853
068703
068803
068903
068513
068704
068804
068904
068523
068705
068805
068905
068514
068706
068806
068906
068524
068707
068807
068907
068516

068722
068822
068922
078035
068723
068823
068923
078667
068724
068824
068924
078668
068725
068825
068925
068547
068726
068826
068926

068742
068842
068942
#
068743
068843
068943
#
068744
068844
068944
#
068745
068845
068945
#
068746
068846
068946
#
068747
068847
068947
#
068748
068848
068948
#
068749
068849
068949
068519
068751
068851
068951
068529

068762
068862
068962
#
068763
068863
068963
#
068764
068864
068964
#
068765
068865
068965
068515
068766
068866
068966
#
068767
068867
068967
068517
068768
068868
068968
#
068769
068869
068969
068520
068771
068871
068971
068522
068772
068872
068972
068528
-

068782
068882
068982
#
068783
068883
068983
#
068784
068884
068984
#
068785
068885
068985
#
068786
068886
068986
#
068787
068887
068987
068526
068788
068888
068988
#
068789
068889
068989
068521
068791
068891
068991
#
068792
068892
068992
068527
068052
068082
068081
068080

#
#
#
#
#
#
#
#
#
#
#
#
068113
#
#
#
#
#
#
#
068114
#
#
#
#
#
#
#
068112
078011
#
068111
068115
078615
068132
#
#
078220
#
078221
#
#
#
#

Use Standard
Schedule 40
Elbow
Use Standard
Schedule 40
Elbow

068727
068827
068927
068525
068728
068828
068928
068130
068729
068829
068929
068518

Use Standard
Schedule 40 Elbow

Use Standard
Schedule 40 Elbow
-

-

Note: # indicates available on request. Material is
non-cancelable and non-returnable.

-

Note: Larger Radius Elbows are available on request
and are non-cancelable and non-returnable.

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

Size
Inches

34

FITTINGS

35

FITTINGS

Schedule 40 Special Radius (Belled One End)
Size
Inches

Degree Bend

SCEPTER CONDUIT
FITTINGS

2-1/2
3
3-1/2
4
5
6

24" Radius
Product Code

36" Radius
Product Code

48" Radius
Product Code

068014
068015
068016
068017
068018
068019
Use Std. Sch. 40
Radius (15")

Use Std. Sch. 40
Radius (24")

068030
068033
068034
068035
068036
068037
068038
068039
068050
068053
Use Std. Sch. 40
Radius (24")

Use Std. Sch. 40
Radius (30")

Use Std. Sch. 40
Radius (30")

068054
068055
068056
068057
068058
068059
068070
068071
068072
068073
068074
068075
068076
068077

068078
068079
068086
068090
068091
068092
068093
068094
068095
068096
068097
068098
068099
068106

Use Std. Sch. 40
Radius (16")

Schedule 80 Special Radius (Belled One End)
Size
Inches
1
1-1/4
1-1/2
2
2-1/2
3
4
5
6

Degree
Bend

18" Radius
Product Code

24" Radius
Product Code

30" Radius
Product Code

36" Radius
Product Code

48" Radius
Product Code

90
45
90
45
90
45
90
45
90
45
90
45
90
45
90
45
90
45

068710
#
068711
#
068712
#
068713
#
068714
#
068715
#
068716
#

#
#
068735
#
#
#
068736
068530
068737
068531
068738
068532
068739
068533

#
#
#
#
#
#
#
#
#
#
#
#
068549
#
#
#

#
#
#
#
068545
#
068775
068534
068776
068535
068777
068536
068778
068537
068779
068538
068540
068539

068541
#
068542
#
068543
#
068544
#
068548
#
068794
#
068795
#
068796
068546
068797
#

Use Standard Schedule 80 Radius (24")

Note: # indicates available on request. Material is noncancelable and non-returnable.

Note: 30º and 22½º Elbows are available on request.
Note: Larger Radius Elbows are available on request and
are non-cancelable and non-returnable.

SCEPTER CONDUIT
FITTINGS

90
45
90
45
90
45
90
45
90
45
90
45
90
45

2

18" Radius
Product Code

36

FITTINGS

37

FITTINGS

Pipe Straps PVC, 2 Hole
Part Number

Product Code

1/2

PS10

077811

Size (in)

Part Number

Product Code

3/4

PS15

077812

1/2

CS10-1

077831

1

PS20

077813

3/4

CS15-1

077832

1-1/4

PS25

077814

1

CS20-1

077833

1-1/2

PS30

077815

1-1/4

CS25-1

077834

2

PS35

077816

1-1/2

CS30-1

077835

2

CS35-1

077836

2-1/2

CS40-1

077837

3

CS45-1

077838

3-1/2

CS50-1

077839

4

CS55-1

077840

Pipe Straps PE, 2 Hole
Size (in)

Part Number

Product Code

2-1/2

PS40

077262

3

PS45

077263

4

PS55

077264

Conduit Clamps and Spacers

PVC Coated Steel, 2 Hole
Size (in)

Part Number

Product Code

Size (in)

Part Number

Product Code

2

CS35

077818

1/2

CCS10

077794

2-1/2

CS40

077819

3/4

CCS15

077796

3

CS45

077820

1

CCS20

077797

3-1/2

CS50

077821

1-1/4

CCS25

077798

4

CS55

077822

1-1/2

CCS30

077799

5

CS60

077824

2

CCS35

077800

6

CS65

077823

Strut Base

CCS-B

077343

CCS-B are sold individually, two pieces are required to create one
base unit.

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

PVC Coated Steel, 1 Hole
Size (in)

38

Access Fittings* Type LB

Access Fittings* Type LL

Size (in)

Part Number

Product Code

Size (in)

Part Number

Product Code

1/2

SLB10S

077541

1/2

SLL10S

077521

3/4

SLB20S

077542

3/4

SLL20S

077522

1

SLB30S

077543

1

SLL30S

077523

1-1/4

SLB40S

077544

1-1/4

SLL40S

077524

1-1/2

SLB50S

077545

1-1/2

SLL50S

077525

2

SLB60S

077546

2

SLL60S

077526

2-1/2

SLB70S

077547

2-1/2

SLL70S

077527

3

SLB80S

077488

3

SLL80S

077528

3-1/2

SLB90S

077549

3-1/2

SLL90S

077530

4

SLB100S

077550

4

SLL100S

077529

Access Fittings* Type LR

Access Fittings* Type C

Size (in)

Part Number

Product Code

Size (in)

Part Number

Product Code

1/2

SLR10S

077481

1/2

SC10S

077501

3/4

SLR20S

077482

3/4

SC20S

077502

1

SLR30S

077483

1

SC30S

077503

1-1/4

SLR40S

077484

1-1/4

SC40S

077504

1-1/2

SLR50S

077485

1-1/2

SC50S

077505

2

SLR60S

077486

2

SC60S

077506

2-1/2

SLR70S

077480

2-1/2

SC70S

077507

3

SLR80S

077488

3

SC80S

077508

3-1/2

SLR90S

077487

3-1/2

SC90S

077510

4

SLR100S

077489

4

SC100S

077509

* Note: All access fittings are UL listed for wet locations.
Supplied with threaded brass inserts, brass screws and PVC gasketing.
Stainless steel screws are available upon request.

* Note: All access fittings are UL listed for wet locations.
Supplied with threaded brass inserts, brass screws and PVC gasketing.
Stainless steel screws are available upon request.

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

39

FITTINGS

FITTINGS

40

41

FITTINGS

FITTINGS

Access Fittings* Type T

Access Fittings* Type TB
K

E

C D

I

Size (in)
1/2
3/4
1
1-1/4
1-1/2
2

Part Number
ST10S
ST20S
ST30S
ST40S
ST50S
ST60S

Product Code

Size (in)

Part Number

Product Code

077461

1/2

STB10S

077451

077462

3/4

STB20S

077452

077463

1

STB30S

077453

077464

1-1/4

STB40S

077454

077465

1-1/2

STB50S

077455

077466

2

STB60S

077456

2-1/2

ST70S

077467

3

ST80S

077468

3-1/2

ST90S

077471

4

ST100S

077572

Access Fittings* Type E

Size (in)

Part Number

J

Product Code

1/2

SE10S

077561

3/4

SE20S

077562

1

SE30S

077563

1-1/4

SE40S

077564

1-1/2

SE50S

077565

2

SE60S

077566

2-1/2

SE70S

077567

3

SE80S

077568

3-1/2

SE90S

077569

4

SE100S

077570

* Notes: All access fittings are UL listed for wet locations.
Supplied with threaded brass inserts, brass screws and PVC gasketing.
Stainless steel screws are available upon request.

Not UL listed.

Access Fitting Dimensions*
Size (in)

A (in)

B (in)

C (in)

D (in)

E (in)

F (in)

1/2

5.606

0.639

1.268

1.100

0.840

4.337

3/4

5.606

0.810

1.536

1.325

1.050

5.395

1

6.500

0.910

1.700

1.600

1.335

6.250

1-1/4

7.900

1.050

2.300

2.000

1.100

7.625

1-1/2

8.500

1.125

2.675

2.250

1.900

8.250

2

10.875

1.160

3.188

2.820

2.375

10.531

2-1/2

14.600

1.750

4.500

3.950

2.870

13.630

3

14.600

1.900

4.500

3.950

3.510

13.630

3-1/2

17.040

2.125

5.536

5.000

4.000

16.000

4

17.040

2.125

5.536

5.000

4.530

16.000

Size (in)

G (in)

H (in)

I (in)

J (in)

K (in)

L (in)

1/2

4.095

1.297

2.487

2.280

1.005

0.750

3/4

4.095

1.297

2.487

2.803

1.005

0.810

1

4.750

1.500

2.075

3.250

1.125

1.115

1-1/4

5.750

1.750

3.575

3.950

1.562

1.300

1-1/2

6.500

1.750

3.938

4.250

1.656

1.425

2

8.156

2.344

4.535

5.438

1.968

1.160

2-1/2

9.825

3.805

6.240

7.300

2.610

-

3

10.897

2.733

6.240

7.300

2.610

-

3-1/2

11.465

4.535

7.500

8.535

2.975

-

4

11.465

4.535

7.500

8.535

2.975

-

* Notes: All access fittings are UL listed for wet locations.
Supplied with threaded brass inserts, brass screws and PVC gasketing.
Stainless steel screws are available upon request.

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

J

L

B

B

42

Service Entrance Fittings

Meter Hubs

Size (in)

Part Number

Product Code

Size (in)

Part Number

Product Code

1/2

EF10

077281

1-1/4

MHU25

077961

3/4

EF15

077282

1-1/2

MHU30

077963

1

EF20

077283

2

MHU35

077965

1-1/4

EF25

077284

2-1/2

MHU40

077967

1-1/2

EF30

077285

3

MHU45

077968

2

EF35

077286

2-1/2

EF40

077287

3

EF45

077288

3-1/2

EF50

077289

4

EF55

077290

Offset Terminal Adapters
(Meter Offsets)

Slip Meter Risers
Schedule 40, Size (in)

Part Number

Product Code

2

SMR35TA

068371

2-1/2

SMR40TA

068372

3

SMR45TA

068373

4

SMR55TA

068374

Note: Meter risers are 2' in length and come complete with male adapter.

Size (in)

Part Number

Product Code

1-1/4

MO25

077941

2

MO35

077942

“Two in One” Pull Elbow
Scepter’s “two in one” access pull elbow reduces inventory
costs and increases installation flexibility (3/4" hub fitting
supplied with 3/4" x 1/2" reducers). The pull elbow is approved
for wet locations and provides for easy wire pulling. They are
manufactured from high impact, nonconducting and
noncorroding PVC.

Long Meter Offsets
(Fabricated)
Size (in)

Part Number

Product Code

1-1/4

LMO25

069641

1-1/2

LMO30

069645

2

LMO35

069646

Size (in)

Part Number

Product Code

1/2 or 3/4

PE15/10

077491

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

43

FITTINGS

FITTINGS

FITTINGS

Nonmetallic Strain Relief Connectors

F Series - Single Gang Plates

Scepter’s Nonmetallic Strain Relief Connectors are supplied
with all the components you need for a complete connection.
The connector body, a selection of grommets and compression
rings accepting a range of cord dimensions, a sealing ‘O’ ring
and metallic locknut are all supplied in one package. Available
in 1/2" and 3/4" threaded hub and 3/4" PVC socket solvent
weld configurations to accommodate a variety of applications.

Threaded, Strain Relief Connector
c/w “O”Ring, Locknut & 4 Grommets

1.415”
dia.

1.610”
dia.

DRC15/10 TSC15/10 20RC15/1020-3RC15/1030-3RC15/10 BRC15/10

Description

Part Number

Product Code

Duplex Receptacle

DRC15/10

077617

Toggle Switch

TSC15/10

077616

Single Receptacle

20RC15/10

077618

Single Receptacle

20-3RC15/10

077619

Single Receptacle

30RC15/10

077620

Blank c/w Gasket

BRC15/10

077611

GASK15/10

077621

PVC Gasket only for F Series Box

Part Number

Product Code

1/2

TSRCU10

077244

3/4

TSRCU15

077261

F Series - Double Gang Plates
GASK20-2

Size (in)

1.760”
dia.

Threaded, Strain Relief Connector
c/w “O”Ring, Locknut & 6 Grommets

BRC20-2-U

TSC20-2-U

DRC20-2-U TSDC20-2-U GASKF20-2-U

Size (in)

Part Number

Product Code

Description

Part Number

Product Code

1/2

TSRC10

077754

Blank Cover c/w Gasket

BRC20-2-U

077359

3/4

TSRC15

077756

Double Switch

TSC20-2-U

077373

Double Duplex Receptacle

DRC20-2-U

077362

Combo Switch Duplex Rec.

TSDC20-2-U

077374

GASK20-2

077743

GASKFU20-2

172650

Socket Solvent Weld Strain Relief Connectors

PVC Gasket

3/4
3/4

Part Number

Product Code

SRC15 c/w 6
grommets
SRCU15 c/w 4
grommets

077985
077209

Strain Relief Connectors Grommet Dimensions
W = .195

W = .285

L = .450

L = .530

W = .220
L = .516

W = .291

Ø = .290

Foam Gasket with Adhesive

Ø = .385

F Series - Triple Gang Plates
GASK20-3

Size (in)

Description

Part Number

Product Code

DRC20-3

077747

DSDR20-3

077745

TSC20-3

077744

Combo Switch Receptacle

TSDC20-3

077746

Blank Cover c/w Gasket

BRC20-3

077748

GASK20-3

077749

Triple Receptacle
Ø = .405

Ø = .500

L = .565

Combo Switch Receptacle
Triple Switch

Ø = .240

Ø = .300"

Ø = .525

Ø = .625

Note: All grommets are supplied with TSRCU10, TSRCU15 & SRCU15.

PVC Gasket

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

45

COVER PLATES

GASK 15/10

44

46

Weatherproof Covers - Single Gang
VPT15/10

Description

(in)

Weatherproof Covers - Double Gang

Part
Number

Product
Code

VPT15/10

077630

Description

Part
Number

Product
Code

VSC20-2-U

VSC15/10

Toggle Switch Cover

VSC15/10

Toggle Switch Cover

VSCU20-2 077376

Combination Switch
& GFI Receptacle

VSRC20-2 077357

Combination Switch
& Duplex Receptacle

VSDRU20-2 077356

077612
VSRC20-2-U

WTG15/10

WDR15/10
RWDR15/10

WGF15/10
RWGF15/10

WTL15
WTL20
WTL30

Grey Toggle Switch
Cover

WTG15/10 077606

Grey Duplex
Receptacle

WDR15/10 077993

White Duplex
Receptacle

RWDR15/10 077786

VSDR20-2-U

Grey Ground Fault
Receptacle

WGF15/10 077785

White Ground Fault
Receptacle

RWGF15/10 077787

Single Receptacle
Device 15 AMP

1.375

WTL15

077992

Single Receptacle
Device 20 AMP

1.625

WTL20

077994

Single Receptacle
Device 30 AMP

1.722

WTL30

077991

VSGG20-2

Double Door GFI
Cover

VSGG20-2 077096

Double Door Duplex
Cover

VSDD20-2 077097

VSDD20-2

Gasket for 2-Gang ‘F’
Boxes (except

GASKFU20-2 172650

VSGG20-2 & VSDD20-2)

Single Receptacle
Device 50 AMP

2.187

WTL50

077951

WTL50

WDRE15/10
RWDRE15/10

Grey Double Door
Duplex Receptacle

WDRE15/10 077087

White Double Door
Duplex Receptacle

RWDRE15/10 077408

Gasket for W Series
Cover (except WDRE

GASKW

077755

GASKDD

072225

Gasket for VSGG20-2
& VSDD20-2 Double
Gangs

GASKV20-2 072227

& RWDRE)

Gasket for WDRE &
RWDRE Covers

Note: Weatherproof covers, with lids closed, are UL
Listed for wet locations.

Note: Weatherproof covers, with lids closed, are UL Listed for wet
locations.

SCEPTER CONDUIT
FITTINGS

Plunger-style Switch
Cover

SCEPTER CONDUIT
FITTINGS

47

WEATHERPROOF COVERS

WEATHERPROOF COVERS

48

49

BOXES

BOXES

F Series Single Gang Boxes

F Series Double Gang Boxes

Outside Dimensions:
Height, 49/16" – Width, 213/16" – Depth 2", Cubic Inches = 25.67

FS-2-U cu.in. = 38.5, FSC-2-U & FSS-2-U cu.in. = 37.0,
FSCC-2-U cu.in.= 35.0, FD-2-U cu.in.= 47.5

FSC

FSS

FSCC

FS

Size (in)

Part Number

Product Code

1/2

FSC10

077607

3/4

FSC15

077608

1/2

FS10

077601

3/4

FS15

077602

1/2

FSCC10

077622

3/4

FSCC15

077623

1/2

FSS10

077604

3/4

FSS15

077605

Part Number

Product
Code

1/2, 3/4, 1

FS-2-101520-U

077364

4.62 4.62

2.5

1/2, 3/4, 1

FSC-2-101520-U

077368

4.62 4.62

2.5

1/2, 3/4, 1

FSS-2-101520-U

077372

4.62 4.62

2.5

1/2, 3/4, 1

FSCC-2-101520-U

077369

4.62 4.62

2.5

Blank

FD-2-U

077649

4.62 4.62

3.0

H

OD (inches)
W
D

FSC-2-101520-U
FSCC-2-101520-U
FD-2-U

FS-2-101520-U

Note: 10 = 1/2" Hub, 15 = 3/4" Hub

FSS-2-101520-U

FD Series Single Gang Deep Boxes
Outside Dimensions:
Height, 49/16" – Width, 213/16" – Depth 23/4", Cubic Inches = 35.30
With the exception of the FD Blank Box, Scepter FD Series
Single Gang Deep Boxes are molded with 1" conduit hubs and
supplied with reducer bushings. The conduit hub(s) are field
modified as 1/2", 3/4" or 1" to accommodate job-site
requirements. The appropriate quantity of 1" x 3/4" and 3/4" x
1/2" reducers to create the desired hub size are packaged with
each FD Series Single Gang Deep Box.
FD Blank

FDS101520

FDC101520

F Series Triple Gang Boxes
FS-3 cu.in. = 56.0, FSC-3 cu.in. = 54.0

Part Number

Product
Code

H

1/2, 3/4, 1

FS-3-101520

077337

4.5

6.6

2.5

1/2, 3/4, 1

FSC-3-101520

077438

4.5

6.6

2.5

Blank

FD-3

077737

4.5

6.6

3.0

Hub Size (in)

H

OD (inches)
W
D

W

D
FS-3-101520

Size (in)

Part Number

Product Code

1/2, 3/4, 1

FDC101520

077291

1/2, 3/4, 1

FDS101520

077299

BLANK

FD BLANK

077603

347 VOLT

FD347

077610

Note: 10 = 1/2" Hub, 15 = 3/4" Hub, 20 = 1" Hub

FSC-3-101520

Note: All F series & octagonal boxes are supplied with integral
mounting feet, threaded brass inserts and grounding clips

FD-3

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

Hub Size
(in)

51

BOXES

BOXES

Octagonal Boxes*

PVC Molded Junction Boxes

Octagonal Boxes are shipped complete with
cover, gasket, 4 reducing bushings (3/4" x
1/2") and 4 sealing caps to be installed from
inside box to seal off unused entry hubs.

Junction boxes are supplied
with threaded brass
inserts, brass screws,
PVC gasketing and
mounting feet. Nylon
and stainless steel
screws, and larger sizes
of fabricated junction
boxes, are available
upon request.

Size (in)

Part Number

Hub Size (in)

Product Code

4 x 1-1/2

OB15/10

1/2 – 3/4

077983*

4 x 2-1/8

OB20

1

077984*

Octagonal Box Extension Rings*
Size (in)

Part Number

Product Code

4 x 1 deep

XR20

077989*

4 x 2 deep

XR35

077990*

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

50

(F = Threaded brass insert size.)

* Octagonal Boxes are not designed for supporting luminaries.
Note: All F series & octagonal boxes are supplied with integral
mounting feet, threaded brass inserts and grounding clips

B
C

Scepter PVC junction boxes are:
NEMA 1, 2, 3, 4, 4X, 6P, 12, 13
UL listed for wet locations

BC

D
E

A
F

A

Threaded Round Box
Scepter’s Threaded Junction Boxes are corrosion resistant,
non-conductive and incorporate high-temperature silicone
gaskets and brass hardware to withstand extreme temperature
variations. Manufactured from glass-reinforced thermoplastic
polyester resin, these boxes can endure extreme temperatures
(material temperature range -40°F to +302°F).
Size (in)

Part Number

Product Code

4 - 3/4" Threaded Hubs

LFB150C

077250

4 - 3/4" Threaded Hubs
c/w 1/2" Threaded Hole in Cover

LFB150T

077251

Part
Number

Product
Code

A
(in)

B
(in)

C
(in)

E
(in)

E
(in)

F
(in)

JB442

077659 3.675 4.000 3.450 2.125 2.000 8-32

JB444

077696 3.675 4.000 3.450 4.188 3.750 8-32

JB446

077669 3.675 4.000 3.450 6.225 6.000 8-32

JB552

077670 4.680 5.000 4.485 2.000 1.845 8-32

JB664

077697 6.000 6.375 5.813 4.180 4.000 10-32

JB666

077698 6.000 6.375 5.813 6.188 6.000 10-32

JB884

077664 8.075 8.625 7.966 4.230 4.005 1/4-20

JB887

077671 8.100 8.625 7.966 7.250 7.035 1/4-20

JB12124 077672 12.085 12.580 11.874 4.256 4.030 1/4-20
JB12126 077666 12.085 12.580 11.874 6.240 6.025 1/4-20
LFB150C

LFB150T

JB12128 077668 12.085 12.580 11.874 8.250 8.025 1/4-20

Fabricated Boxes
Unflanged PVC fabricated boxes of any size may be made to
customers’ specifications and come complete with lids,
gaskets and screws. These boxes are not UL Listed and are not
returnable.

53

BOXES

BOXES

Flanged Box with Fiber-Reinforced Safety
Tread Cover

Nonmetallic Floor Box, Cover & Metal Cover
Adapter

Scepter’s Flanged ‘H’ Series Junction Boxes provide H10 Highway
Loading. The fiber-reinforced safety tread cover secures using
recessed Hex Key fastening hardware offering a simple installation
while reducing the opportunity for tampering.

Installation is quick and simple with our nonmetallic floor box
and covers, saving both time and money over similar metallic
assemblies.

H887

H887-A

CC
B

A

Part
Number

Product
Code

L

Box ID (in)
W
D

H664

077685

6

6

4-1/4

H666

077686

6

6

6-1/4

H884

077687

8

8

4-1/4

H886

077688

8

8

6-1/4

H887

077689

8

8

7-1/4

H887-A 077692

8

8

7-1/4

Lid Dimensions (in)
A
B
C
9.0

9.0

0.60

9.0

9.0

0.60

11.5

11.5

0.75

11.5

11.5

0.75

11.5

11.5

0.75

11.5

11.5

0.75

Scepter’s floor box and duplex receptacle covers are constructed
from high impact, noncorroding and nonconducting PVC.
The flush-mount covers are available in custom colors and are
shipped with a leveling ring. Metal cover adapter kits are also
available, allowing you to adapt to metal floor plates. Our 6" deep
floor box allows flexibility for various concrete floor pours, while the
4-3/4" width offers easy access and ample wire room. Scepter’s FB
box is molded with 2 - 1" and 2 - 3/4" hub openings.
All boxes are shipped complete with reducer plugs for added
versatility.

Description

Product
Code

Part
Number

Floor Box Base
(Includes disposable protective cap & reducer plugs)

076954

FB

Junction Box Adapters

Floor Box Base c/w Leveling Ring Adapter

Junction Box Adapters, installed using
a standard PVC coupling, offer a
trouble-free and reliable PVC
connection. In addition to providing a
strong connection, the JBA also
maximizes the interior box wiring
space unlike the use of male adapters
(TA) and facilitates wire pulling - the
smooth internal edges limiting the
potential for wire damage.

(includes disposable protective cap, reducer plugs
& leveling ring adapter)

077068

FB

FBKIT

Floor Box Stand Kit (includes FB Box)
FBS-KIT

Junction Box Standard PVC
Coupling
Adapter

(is equiped with several height brackets which
accommodate the different rebar and post-tension cable heights and
slab depths found from job-site to job-site.)

Junction box and couplings
sold separately

077700

FBSKIT

Metal Cover Adapter Kit
Size (in)

Part Number

Product Code

1/2

JBA10

077721

3/4

JBA15

077722

1

JBA20

077723

1-1/4

JBA25

077724

1-1/2

JBA30

077725

Floor Box Duplex Receptacle Cover (Nonmetallic)
(includes flush mount cover, blank cover & gasket)

2

JBA35

077726

2-1/2

JBA40

077727

3

JBA45

077728

3-1/2

JBA50

077729

4

JBA55

077730

(includes leveling ring, metal cover adapter & 2 gaskets)

076953

AFMC

AFMC

Universal Leveling Ring Adapter
076606

Brown
Gold
Grey
Light Almond

076955
076949
076600
076605

LRA-U

FBDRCB
FBDRCG
FBDRCGr
FBDRCA

LRA-U

FBDRC

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

52

54

COVER PLATES / CEMENTS & PRIMER

55

SPACERS

Tri-Service Universal Divider Kit
(includes upper & lower dividers, riser tube & two grommets)

B
B

077948

FBUDK

FBUDK

A
077499

C

FBYC

SCEPTER CONDUIT
FITTINGS

SCEPTER CONDUIT
FITTINGS

Y Connector (3/4")

C
FBYC

B

Brass Cover Plates
(offers a one-piece design measuring 5-3/4"
diameter. Are available in a variety of
styles accommodating power and
communication needs. Install to the FB
box using the universal leveling ring adapter.

B

A

B1

Description

Part Number

Product Code

Duplex Screw Cover

DSC

178091

Duplex Screw Cover

DSC-P/C

178092

Single Screw Cover

SSC

178093

Single Screw Cover

SSC-P/C

178094

Duplex Flip Lid (single)

DFL-1

178095

Duplex Flip Lid (double)

DFL-2

178096

Part Number Product Code

250ml (1/2 Pint)

S100PT5

078883

500ml (Pint)

S100PT

078884

1L (Quart)

S100QT

078885

4L (Gallon)

S100GAL

078887

Scepter 100 - Cold Weather / Wet Weather
Cement
Size

A1

B
B

Intermediate
Vertical-Lok Spacers

Cements
Size

B

Part Number Product Code

Dimension
Product
Part Number
(in)
Code

A inches

B inches

C inches

2 x 1-1/2

IS3530

029550

1.500

3.937

0.62

2x2

IS3535

029551

2.000

4.488

0.62

2x3

IS3545

029552

3.000

5.433

0.62

3 x 1-1/2

IS4530

029553

1.500

5.130

no rebar slots

3x2

IS4535

029554

2.000

5.630

0.87

3x3

IS4545

029555

-

6.614

0.87

4x1

IS5520

029556

1.000

5.630

no rebar slots

4 x 1-1/2

IS5530

029557

-

6.614

0.87

500ml (Pint)

CWC10

078503

4x2

IS5535

029558

2.000

6.614

0.87

1L (Quart)

CWC20

078886

4x3

IS5545

029559

3.000

7.638

0.87

5 x 1-1/2

IS6030

029560

1.500

7.325

no rebar slots

5x2

IS6035

029561

2.188

7.874

0.87

5x3

IS6045

029562

3.188

8.701

0.87

6 x 1-1/2

IS6530

029563

-

7.441

0.87

6x2

IS6535

029564

-

7.677

0.87

6x3

IS6545

029565

3.000

9.764

0.87

8x2

IS8035

029294

-

-

no rebar slots

Primer

c/w Applicator Cap

Size

Part Number Product Code

250ml (1/2 Pint)

C100PT5

078163

500ml (Pint)

C100PT

078174

1L (Quart)

C100QT

078175

56

SPACERS / CONDUIT REPAIR KIT

57

CONDUIT REPAIR KIT

EPR Kits for Conduit Repair

SCEPTER CONDUIT
FITTINGS

Base
Vertical-Lok Spacers
Dimension
Product
Part Number
(in)
Code

A inches

B inches

C inches

EPR Kits from IPEX are the first total
repair systems for broken and damaged
PVC conduit. They offer fast and easy
repairs for damaged conduit caused by
actions such as earth excavation,
horizontal and core drilling.
All sizes are 24 inches in length.

BS3530

029566

2.992

3.937

0.62

2x2

BS3535

029567

2.992

4.488

0.62

2x3

BS3545

029568

2.992

5.433

0.62

Size (in)

Part Number

Product Code

Length (in)

3 x 1-1/2

BS4530

029569

3.000

4.615

no rebar slots

1-1/4

EPR25

077976

24

3x2

BS4535

029570

2.992

5.630

0.87

1-1/2

EPR30

077971

24

3x3

BS4545

029571

2.992

6.614

0.87

2

EPR35

077972

24

4x1

BS5520

029572

1.750

4.060

no rebar slots

2-1/2

EPR40

077973

24

4 x 1-1/2

BS5530

029573

2.992

6.614

0.87

3

EPR45

077974

24

4x2

BS5535

029574

2.992

6.614

0.87

4

EPR55

077975

24

4x3

BS5545

029575

2.992

7.638

0.87

5

EPR60

077977

24

5 x 1-1/2

BS6030

029576

3.000

6.900

no rebar slots

6

EPR65

077979

24

5x2

BS6035

029577

2.992

7.874

0.87

5x3

BS6045

029578

2.992

8.701

0.87

6 x 1-1/2

BS6530

029579

3.031

7.441

0.87

6x2

BS6535

029580

3.031

7.677

0.87

6x3

BS6545

029581

2.992

9.764

0.87

8x2

BS8035

029293

-

-

no rebar slots

CONDUIT REPAIR KIT

2 x 1-1/2

SCEPTALIGHT: The Light That Lasts
Sceptalight fixtures from IPEX prove themselves to be all-round
performers in a variety of indoor and outdoor applications.
Sceptalight fixtures are made from a glass-reinforced
thermoplastic polyester resin, which enable them to stand up
better to corrosive elements than metal. This thermoplastic
design marries an unrivaled balance of strength, stiffness and
toughness with all the benefits users appreciate of Scepter
rigid PVC conduit and fittings - long life, easy servicing and
high impact-resistance.
Sceptalight's thermoplastic construction offers outstanding
corrosion and chemical resistance. And its interior and exterior
silicone gaskets create a watertight seal, the reason it performs
equally well indoors and outside.

Features and Benefits
• Stable Construction
• Watertight seal with weather-resistant silicone gaskets
• Corrosion Resistant
• Durable and Impact Resistant

Mounting Options
CEILING MOUNT

Box with four 3/4"
threaded hubs and
integral mounting feet.

WALL MOUNT

Box with four 3/4"
threaded hubs, 90º wall
bracket and integral
mounting feet.

PENDANT MOUNT

Pendant cap with
3/4" threaded hub
and a locking set
screw.

SCEPTALIGHT

____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________

59

SCEPTALIGHT TM

NOTES

60

Globe Options
Sceptalight offers a variety of globe options to suit a wide range
of applications and environments. Our standard clear glass
globes are ideal for general purpose area lighting for either
indoor or outdoor use. Polycarbonate globes offer impact
resistance in case of accidental contact and the assurance that
work areas are not contaminated by broken glass. Colored
globes - available in red, blue, green or amber - can transform
the light to an indicator or warning light.

Wet Locations

C22.2 No. 250
UL 1598
Minimum 60ºC supply conductors

Ceiling Mount
4 3/4"

6"

4 3/4"

11 3/4"

Ceiling Mount

Heat-treated
Blue Glass

Heat-treated
Green Glass

Heat-treated
Red Glass

Heat-treated
Amber Glass

Light Options
Fluorescents
Our compact fluorescent fixtures work four to five times more
efficiently per watt than incandescents and provide 10-20
times the lamp life, yet use approximately 75% less energy. In
this way, Sceptalight fluorescents lower energy and maintenance
costs without sacrificing light levels.

Incandescents
With their low initial cost, Sceptalight incandescent fixtures
make the most practical choice to meet the daily needs of
commercial, industrial, marine and agricultural applications.
Our incandescents are ideal for short burn times as well as
flashing and dimming applications.

Ceiling Mount
Polycarbonate Globe

Part
Number

Product
Code

150W

Incandescent

LVPF150C

077225

150W

Incandescent less guard

LVPF150LG

077237

26W

Compact Fluorescent

LVPL26C

077170

18W

Compact Fluorescent

LVPL18C

077210

13W

Compact Fluorescent

LVPL13C

077122

9W

Compact Fluorescent

LVPL9C

077121

7W

Compact Fluorescent

LVPL7C

077120

Part
Number

Product
Code

Ceiling Mount with Clear Polycarbonate
Glass Globe (no guard)
26W

Compact Fluorescent

LVPL26PCC

077176

18W

Compact Fluorescent

LVPL18PCC

077211

13W

Compact Fluorescent

LVPL13PCC

077165

9W

Compact Fluorescent

LVPL9PCC

077155

7W

Compact Fluorescent

LVPL7PCC

077145

Wall Mount Bracket
Description

Part
Number

Product
Code

Use with Wet, Marine and Hazardous
locations. For wall mount fixtures select
and order the appropriate style (wattage
and globe) ceiling mount fixture from
above and add LWB150.

LWB150

077233

SCEPTALIGHT

SCEPTALIGHT

Ceiling Mount
with Standard Clear Glass Globe
Standard or Heat-treated
Clear Glass

9 1/2"

10"

Ceiling Mount

Clear
Polycarbonate

61

SCEPTALIGHT TM

SCEPTALIGHT TM

62

Wet
Locations

Hazardous
Locations

4 3/4"

4 3/4"

con’t

UL 844
Class I, DIV 2 Groups A,B,C & D
Class II, DIV 2 Groups F & G
Minimum 90oC supply conductors

Ceiling Mount

Pendant Mount
12"

Pendant Mount
with Standard Clear Glass Globe

10 1/4"

Ceiling Mount
with Heat Resistant Glass Globe

Part
Number

Product
Code

150W Incandescent clear

LVPF150HRC-HAZ

077414

LVPF150HRR-HAZ 077415

Part
Number

Product
Code

150W Incandescent red
150W Incandescent blue

LVPF150HRB-HAZ 077416

150W

Incandescent

LPMF150C

077231

150W Incandescent green

LVPF150HRG-HAZ 077417

26W

Compact Fluorescent

LPPL26C

077184

150W Incandescent amber

LVPF150HRA-HAZ

077494

18W

Compact Fluorescent

LPPL18C

077212

26W Compact Fluorescent clear

LVPL26HRC-HAZ

077377

13W

Compact Fluorescent

LPPL13C

077185

26W Compact Fluorescent red

LVPL26HRR-HAZ

077378

9W

Compact Fluorescent

LPPL9C

077183

26W Compact Fluorescent blue

LVPL26HRB-HAZ

077379

7W

Compact Fluorescent

LPPL7C

077182

26W Compact Fluorescent green

LVPL26HRG-HAZ

077399

Part
Number

Product
Code

26W Compact Fluorescent amber LVPL26HRA-HAZ

077400

Pendant Mount with Clear
Polycarbonate Globe (no guard)

18W Compact Fluorescent clear

LVPL18HRC-HAZ

077347

26W

Compact Fluorescent

LPPL26PCC

077375

18W Compact Fluorescent red

LVPL18HRR-HAZ

077348

18W

Compact Fluorescent

LPPL18PCC

077273

18W Compact Fluorescent blue

LVPL18HRB-HAZ

077349

13W

Compact Fluorescent

LPPL13PCC

077365

18W Compact Fluorescent green

LVPL18HRG-HAZ

077353

9W

Compact Fluorescent

LPPL9PCC

077355

18W Compact Fluorescent amber LVPL18HRA-HAZ

077354

7W

Compact Fluorescent

LPPL7PCC

077345

Wall Mount Bracket
Marine
Locations

C22.2 No. 250
UL 1598, UL 1598A, UL 1598
Minimum 110oC supply conductors

Ceiling Mount
Ceiling Mount
with Heat Resistant Glass Globe
100W

Incandescent

Part
Number

Product
Code

LVPF100C-MAR

077275

Part
Number

Product
Code

LPMF100C-MAR

077276

Pendant
Ceiling Mount
with Heat Resistant Glass Globe
100W

Incandescent

Description
Use with Wet, Marine and Hazardous
locations. For wall mount fixtures select
and order the appropriate style (wattage
and globe) ceiling mount fixture from
above and add LWB150.

Part
Number

Product
Code

LWB150

077233

Pendant Mount
Pendant Mount
with Heat Resistant Glass Globe

Part
Number

Product
Code

150W Incandescent clear

LPMF150HRC-HAZ

077495

150W Incandescent red

LPMF150HRR-HAZ

077496

26W Compact Fluorescent clear

LPPL26HRC-HAZ

077407

26W Compact Fluorescent red

LPPL26HRR-HAZ

077409

18W Compact Fluorescent clear

LPPL18HRC-HAZ

077500

18W Compact Fluorescent red

LPPL18HRR-HAZ

077498

SCEPTALIGHT

SCEPTALIGHT

63

SCEPTALIGHT TM

SCEPTALIGHT TM

64

Nonmetallic Utility Light Fixture
LVPE150-PCC

LVPE150

65

SCEPTALIGHT TM

SCEPTALIGHT TM

Accessories & Components
*

5 1/8"

5 1/8"

Standard Glass Globes
3 1/2"

9 7/8"

Description

Part Number

Product Code

Clear

LGC150

077247

11"

LVPUG150

LVPE150-1015G

Globe Description

Part
Number

Hub
Size (in)

Product
Code

Fixture c/w
Clear Glass Globe

LVPE150-10/15

1/2 x 3/4

077493

Fixture c/w Clear
Polycarbonate Globe

LVPE150-PCC*

1/2 x 3/4

077181

Fixture c/w Heat
Resistant Clear Globe

LVPE150-HRC

1/2 x 3/4

077578

Fixture c/w Heat
Resistant Red Globe

LVPE150-HRR

1/2 x 3/4

077599

Fixture c/w Heat
Resistant Blue Globe

LVPE150-HRB

1/2 x 3/4

077579

Fixture c/w Heat
Resistant Green Globe

LVPE150-HRG

Fixture c/w Heat
Resistant Amber Globe
Replacement
Clear Glass Globe
Nonmetallic
Clamp-on Guard
Fixture c/w
Clear Glass Globe &
Clamp-on guard

LVPE150-HRA

1/2 x 3/4
1/2 x 3/4

077597
077598

LGC150

077247

LVPUG150

077558

LVPE150-1015G

1/2 x 3/4

077402

* Maximum 60W incandescent lamp with polycarbonate globe

Description

Part Number

Product Code

Clear

LG150T

077909

Red

LCGR150T

077239

Blue

LCGB150T

077910

Green

LCGG150T

077241

Amber

LCGA150T

077242

Polycarbonate Globes (for use with
compact fluorescent or maximum 60W incandescent lamp)
Description

Part Number

Product Code

Clear

LPCC18

077911

Red

LPCR18

077912

Blue

LPCB18

077913

Green

LPCG18

077914

Amber

LPCA18

077915

SCEPTALIGHT

SCEPTALIGHT

Heat Resistant Globes

KWIKFLEX: NMLT Conduit & Fittings
Kwikflex® NMLT Type B on reels are UL listed in all lengths
Available in sizes from 3/8" to 2", reels offer the end user the
best possible continuous length in the market place. Its
patented design offers a low profile coupling that when two
conduits are connected it is hardly noticeable and allows the
user to run the conduit at any length desirable. There is no
longer any need for additional parts when making a long
conduit run.
Kwikflex NMLT is also available in extra-flexible formulations in
sizes 3/8" to 2"
Coils come packaged in easy to ship cartons
Coils are conveniently packaged in cardboard boxes to keep the
pipe clean and come with a center knock-out for easy dispensing.

Applications
• HVAC equipment
• Machine tools
• Marine equipment
• Motors & controls
• Printing equipment
• Pumps
• Refrigeration equipment
• Transformer connections
• Outdoor lighting

KWIKFLEX

____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________

67

KWIKFLEX ®

NOTES

68

KWIKFLEX ®

69

KWIKFLEX ®

NMLT Flexible Conduit
(Grey) Type B

NMLT 90º Elbows (Grey)

Size (in)

Part Number

Product code

3/8

LTB03/90

065306

Size (in)

Product Code

Length (ft)

1/2

LTB10/90

065307

3/8

165005

100

3/4

LTB15/90

065310

1/2

165007

100

1

LTB20/90

065312

3/4

165009

100

1-1/4

LTB25/90

065314

1

165011

100

1-1/2

LTB30/90

065317

1-1/4

165014

100

2

LTB35/90

065320

1-1/2

165017

50

1-1/2

165021

100

2

165020

50

NMLT Straight Fittings (Grey)

Size (in)
1/2
3/4
1

Product Code
165082
165085
165090

Length (ft)
1000
700
500

NMLT Extra Flexible Tubing
(Black)

Size (in)

Part Number

Product code

3/8

LTS03

065326

1/2

LTS10

065327

3/4

LTS15

065330

1

LTS20

065332

1-1/4

LTS25

065334

1-1/2

LTS30

065337

2

LTS35

065340

NMLT Screw-on 90º Elbows
(Grey)

Size (in)

Product Code

Length (ft)

3/8

165055

100

1/2

165057

100

3/4

165059

100

Size (in)

Part Number

Product code

1

165061

100

1/2

LTD10/90

065350

1-1/4

165064

100

3/4

LTD15/90

065352

1-1/2

165067

100

2

165070

100

Other packages sizes available on request

KWIKFLEX

KWIKFLEX

NMLT Flexible Conduit Reels
(Grey) Type B

70

KWIKFLEX ®

71

KWIKON ® ENT

NMLT Screw-on Straight Fittings
(Grey)

Size (in)

Part Number

Product code

1/2

LTD10

065360

3/4

LTD15

065362

KWIKFLEX

NMLT Screw-on Multi Angle
Fittings (Grey)

Size (in)

Part Number

Product code

1/2

LTMA10

065015

3/4

LTMA15

065016

Kwikon® ENT Savings for the Long Run

Now you can use the Kwikon ENT system for communications
(yellow), fire alarm and emergency (red), as well as power
(blue) applications. It comes with color-coded stripes for easy
identification on 1,500 ft., 1000 ft. and 750 ft. reels. The
Kwikon ENT system is the right choice.

Kwikon Fittings
Our unique Kwikon couplings, transition couplings and
connectors are designed with six 360° locking tabs to ensure a
secure concrete-tight connection.
Time-consuming taping and solvent welding are eliminated.
Kwikon fittings are permitted for use with all UL Listed and
CSA certified ENT.

UL 514B, UL 514C
UL 1653

TC-13

C22.2 No. 21127, C22.2 No. 85
FT-4 Rated

KWIKON ENT

Noncorroding and nonconducting, Kwikon Electrical Nonmetallic
Tubing and fittings are designed For The Long Run. Coiled in
lengths up to 1,500 feet, the Kwikon system can span the
longest run. Encased in concrete, concealed in walls or ceilings,
Kwikon offers the best alternative to the labor-intensive, 10'
lengths of metal conduit with its couplings and scrap.

72

ENT TUBING

Ease of Installation

Exposed Work

Engineered for the rugged day-to-day
challenges of the construction industry,
Kwikon has already established itself as
a market leader. Requiring no special
tools for bending or cutting, Kwikon is
easily installed.

ENT is permitted to be used for exposed work, where not subject
to physical damage, in buildings not exceeding 3 floors above grade.

Bending & Cutting
Kwikon’s corrugated construction allows
it to be easily bent by hand, no longer
requiring special bending equipment
traditionally required with metal conduit
systems. When bending, ensure the
radius of the curve is at least six times
the internal diameter of the tubing.

Kwikon Slab Boxes
Kwikon slab boxes are available with or
without molded connectors. For boxes
without molded connectors, preassembly
is quick and simple using our threaded
male adapter with locknuts. This provides
a secure concrete-tight connection.

Pulling Wire
Kwikon’s interior corrugated surface
greatly reduces the amount of friction
while pulling conductors through long
runs, even with 90° bends.

Transition from ENT to EMT
Transition from ENT to EMT no longer
requires solvent welding. Simply connect
the Kwikon transition coupling to EMT
with the set screw and snap on to ENT.

NEC, Article 362
Rules governing the installation of
Kwikon ENT are covered in the 2011
National Electrical Code, ANSI/NFPA
Article 362. Kwikon ENT systems are
recognized for use in places of assembly
as referenced in Articles 518 & 520.
Kwikon ENT may be installed exposed, in
areas not subject to physical damage
where the building does not exceed three
floors above grade [(362.10 (1)].

Metal slab boxes can be quickly
preassembled with Kwikon connectors.
Secured with a locknut, Kwikon connectors
provide a concrete-tight connection.

Kwikon ENT may be concealed in floors, walls, ceilings and
suspended ceilings where a thermal barrier of material has a
minimum of 15-minute finish rating. NOTE: Kwikon ENT may
penetrate fire-rated walls, floors or ceilings with a UL Listed or
recognized through-penetration fire-stop system.

Installation in Sheer Walls,
Interior Walls & Block Walls

Fire Resistive Construction & Wall Assemblies

Kwikon’s flexibility, lightweight and ease of
handling in metal, wood or block walls,
combined with Kwikon connectors and
couplings, substantially reduce time and
labor needed to install electrical raceways.

Use in Ceilings
Kwikon ENT is permitted for use in
ceilings where not subject to physical
damage and in buildings 3 storeys or more
provided the ceiling provides a 15-minute
finish rating.

Kwikon ENT tubing, Kwikon fittings and
Kwikon slab boxes are approved for use in
noncombustible 2 hr. and 4 hr. fire rated
floor-ceiling assemblies. Normal weight
concrete cover must be provided of a
minimum of 2-1/8" for 2 hr. assemblies
and 2-3/8" for 4 hr. assemblies. [ULI File:
E 78276 and ULC File: R-19226].
Kwikon ENT and Kwikon fittings have
been investigated for use in a nonloadbearing wall and partition assembly. The
report (ULC CR2196) concludes the wall
assemblies with Kwikon ENT and fittings
will provide a 2 hr. resistance to the
passage of flame and dangerous
transmission of heat.

KWIKON ENT

KWIKON ENT

Pre-Assembly of Metallic
Boxes

73

ENT TUBING

74

ENT TUBING

Kwikon ENT - Blue Stripe

Kwikon Coupling
Product Code

KC10

089000

3/4

KC15

089001

1

KC20

089002

1-1/4

KC25

189670

1-1/2

KC30

189671

2

KC35

189672

1500

012002

165

3/4

1000

012011

158

1

750

012021

160

1-1/4

1000

012047

193

1-1/2

750

012033

205

2

500

012044

220

1/2

200

012031

20

3/4

100

012040

12.5

1

100

012041

17

1-1/4

500

012046

76

1-1/2

300

012032

50.5

Size (in)

Part Number

Product Code

2

225

012043

69.5

1/2

KTA10

089006

3/4

KTA15

089007

1

KTA20

089008

1-1/4

KTA25

189680

1-1/2

KTA30

189681

2

KTA35

189682

Reel

1/2

Wrapped in plastic, coils are easily dispensed from the center.

Kwikon ENT Reels - Color Coded

Kwikon Connector For
Concrete Encasement

Red

Product Code
Yellow

Blue

Weight
lbs/reel

1500

012305

012335

012002

165

3/4

1000

012307

012337

012011

158

1

750

012310

012340

012021

160

1-1/4

1000

012037

012038

012047

193

1-1/2

750

012035

012036

012033

205

Size (in)

Part Number

Product Code

2

500

012039

012042

012044

220

1/2

KTS10

089146

3/4

KTS15

089147

1

KTS20

089148

Length
(ft)

1/2

Kwikon ENT - 10' Sticks with Blue Stripe
Size (in)

Length (ft)

Product Code

Crate Qty

1/2

10

012001

3,600

3/4

10

012010

2,200

1

10

012034

1,800

All Kwikon ENT is UL Listed for use in walls, floor slabs and
ceilings, as outlined in Article 362 of the 2005 NEC Code.

Storage of Kwikon ENT Tubing

Kwikon Snap-in Connector

Kwikon Transition Coupling
Size (in)

Part Number

Product Code

1/2

KTC10

089012

3/4

KTC15

089013

1

KTC20

089014

Manufacturer recommends that ENT tubing should not be
stored outdoors where subjected to direct sunlight without
protective covering, i.e. packaging or tarps.
E 59258, E 119384

E 122659

TC-13

TC-13

C22.2 No. 227.1

KWIKON ENT

KWIKON ENT

Part Number

1/2

Length (ft)

Coil

Product Code Weight lbs/pkg

Size (in)

Size (in)

Size
(in)

75

KWIKON ® COUPLINGS / CONNECTORS

76

KWIKON ® COUPLINGS / CONNECTORS

Kwikon 90o Stub Down Fittings
KT90 Stub Down Fittings
(Kwikon x Threaded)
Size (in)

Part Number

Product Code

1/2

KT90-10

089060

3/4

KT90-15

089059

1

KT90-20

089058

KK90 Stub Down Fittings
(Kwikon x Kwikon)
Size (in)

Part Number

Product Code

1/2

KK90-10

089055

3/4

KK90-15

089056

1

KK90-20

089057

77

KWIKON ® ESU & ACCESSORIES

The NEW ENT Support Unit (ESU)
raises the tubing or conduit up off the concrete form
during the concrete pour maintaining a level
raceway and allows for maximum aggregate flow and
concrete consolidation.
Easy to use, the ESU snaps around any size of ENT.
It is perfect for use in high rise buildings constructed with posttensioned (PT) concrete slabs.

Features
•
•
•
•
•

Part Number

Product Code

ESU-10-35

089149

One size fits all 1/2" - 2"
Saves time and labour
Easy locking mechanism
Securable to the concrete form
Minimal footprint reduces amount of surface contact

Size (in)

Part Number

Product Code

1/2

KSTB-10

089330

3/4

KSTB-15

089331

1

KSTB-20

089332

1-1/4

KSTB-25

089333

Kwikon ENT Multi-LinkTM
Form Stubby
Size (in)

Part Number

Product Code

1/2

MSTB-10

089031

3/4

MSTB-15

089026

1

MSTB-20

089025

Kwikon ENT Angled Form Stubby
Size (in)

Part Number

Product Code

1/2

KASTB-10

089233

3/4

KASTB-15

089234

1

KASTB-20

089235

1-1/4

KASTB-25

089236

1-1/2

KASTB-30

089238

Accessories
Tapered Plugs
Size (in)

Part Number

Product Code

1/2

TP10

089003

3/4

TP15

089004

1

TP20

089005

Kwikon Cutter & Blades
Description

Part Number

Product Code

Cutter (1/2"- 1")

CLC20

089066

Blades for CLC20

SSB

089067

Cutter (1/2"- 2")

CLC35

089068

Blades for CLC35

SB35

089069

KWIKON ENT

KWIKON ENT

Kwikon ENT Form Stubby

78

KWIKON ® SLAB BOXES

79

KWIKON ® SLAB BOXES

Shallow Slab Box

Kwikon Slab Boxes
Engineered to be rugged and durable, Kwikon slab boxes
withstand construction’s harshest environments. Designed by
contractors for contractors, Kwikon slab boxes are available in two
unique styles, with or without molded connectors. Now you can
provide a complete, nonmetallic slab system. priced competitively
with traditional steel mud boxes, Kwikon slab boxes increase
labor efficiencies, reducing costs.

Standard Slab Boxes
• Approved for support of ceiling fans up to 35 lbs and
luminaries up to 50 lbs
• Corner and traditional mounting tabs offer contractors two
options when installing to the slab deck
• Angled design guides the nail into position within the trim
cover area
• Ready to install – no assembly required
• Clear Vue vacuum formed removable covers

Shallow Slab Box with Molded Connectors
Hub Size (in)

Part Number

Product Code

8 x 1/2

SMBS-H-10

089480

4 x 1/2 & 4 x 3/4

SMBS-H-10/15

089481

8 x 3/4"

SMBS-H-15

089482

4 x 1/2, 2 x 3/4, 2 x 1

SMBS-H-10/20

089483

4 x 3/4 & 4 x 1

SMBS-H-15/20

089484

Shallow Slab Box without Molded Connectors
Hub Size (in)

Part Number

Product Code

8 x 1/2

SMBS-10

089490

4 x 1/2, 2 x 3/4, 2 x 1

SMBS-10/20

089491

Hub Size (in)

Part Number

Product Code

8 x 1/2

SMB-H-10

089465

8 x 3/4

SMB-H-15

089462

4 x 1/2, 4 x 3/4

SMB-H-10/15

089458

4 x 1/2, 2 x 3/4, 2 x 1

SMB-H-10/20

089466

4 x 3/4, 4 x 1

SMB-H-15/20

089464

Slab Box without Molded Connectors
Knockout Size (in)

Part Number

Product Code

8 x 1/2

SMB-10

089460

4 x 1/2, 2 x 3/4, 2 x 1

SMB-10/20

089461

ENT Slab Box
Slab Box with Molded Connectors (Hubs)
Description

Part Number

Product Code

8 x 1/2" connectors

MBH-10

089022

8 x 3/4" connectors

MBH-15

089018

4 x 1/2", 4 x 3/4" connectors

MBH-10/15

089020

4 x 1/2", 2 x 3/4", 2 x 1"
connectors

MBH-10/20

089019

4 x 3/4", 4 x 1" knockouts

MBH-15/20

089021

Slab Box with Knockouts (w/o Molded Connectors)

4" Square Slab Box
Slab Box with Molded Connectors
Hub Size (in)

Part Number

Product Code

8 x 1/2

SSBH-10

089467

8 x 3/4

SSBH-15

089468

4 x 1/2, 2 x 3/4,

SSBH-10/15

089469

4 x 1/2, 2 x 3/4, 2 x 1

SSBH-10/20

089474

4 x 3/4, 4 x 1

SSBH-15/20

089475

Description

Part Number

Product Code

4 x 1/2", 2 x 3/4", 2 x 1"

MB-10/20

089016

8 x 1/2" knockouts

MB-10

089017

KWIKON ENT

KWIKON ENT

Slab Box with Molded Connectors

80

KWIKON ® SLAB BOXES

ENT Wall Boxes, Ceiling Boxes & Covers

Concrete Wall Box
•
•
•
•
•

81

KWIKON ® SLAB BOXES

Fully assembled and installation ready
Perfectly suited for deep or shallow construction preferences
Concrete-tight poly film covering the box opening
Kwikon hubs do not protrude inside the box
Clear Vue vacuum formed removable covers

3-1/2" Deep Boxes
Size (in)

Part Number

Product Code

4 x 1/2 & 4 x 3/4

SVDB-H-10/15

089496

4 x 3/4 & 4 x 1

SVDB-H-15/20

089049

4 x 1/2, 2 x 3/4, 2 x 1

SVDB-H-10/20

089052

8 x 3/4"

SVDB-H-15

089065

Size (in)

Part Number

Product Code

KCB-10

089506

KDCB-10/15

089507

Switch Box 3-1/16" Deep

KSB-10/15

089508

4" Square Box 1-1/2" Deep

KDSB-2-10

089509

4" Square Box 2-1/8" Deep

KDSB-2-10/15

089510

Raised 1/2" Single Device

KRC-10

089501

Raised 5/8" Single Device

KRC-15

089502

Raised 1/2" Two Devices

KRCD-2-10

089503

Raised 5/8" Two Devices

KRCD-2-15

089504

Round Flat Cover, 1/2" KO

KFC-10

089505

Square Flat Cover, 1/2" KO

KWBC-10

089500

KVP

089512

Ceiling Box 2-1/16" Deep
4" Set-Up Box 2-1/16" Deep

Voltage Partition

2" Shallow Boxes
Hub Size (in)

Part Number

Product Code

4 x 1/2

SVSB-H-10

089054

4 x 3/4

SVSB-H-15

089053
KSB-10/15

KDSB-2-10/15

KDSB-2-10

KCB-10

Floor Box Stand Kit

KRC-10

KRC-15

KRCD-2-10

KRCD-2-15

KWIKON ENT

KWIKON ENT

KDCB-10/15

includes FB Box

Is equiped with several height brackets which accommodate
the different rebar and post-tension cable heights and slab
depths found from job-site to job-site.
Product Code

Part Number

FBS-KIT

077700

For full product selection see page 51

FBS-KIT

KVP

KFC-10

KWBC-10

82

83

SHORT FORM SAMPLE SPECIFICATIONS

SHORT FORM SAMPLE SPECIFICATIONS

Short Form Sample Specification
General
References:

Fittings:

Standards referred to in this section are:

ENT fittings shall be manufactured of high impact PVC

• UL 1653 Electrical Nonmetallic Tubing

ENT fittings requirements:

• NEMA TC-13 Electrical Nonmetallic Tubing

Provide fittings meeting the following requirements:
• Six locking tabs located every 60º proving 360º contact

Products
Manufacturers:

• Locking tabs shall provide a pullout of a minimum
175 ft-lb force

Acceptable manufacturers are listed below:

• Concrete tight without the need for taping

• Electrical Nonmetallic Tubing - Kwikon by IPEX
• Electrical Nonmetallic Tubing Fittings - Kwikon by IPEX
• Electrical Nonmetallic Tubing Boxes - Kwikon by IPEX
All ENT tubing, ENT fittings, ENT boxes and accessories shall be
manufactured by the same company so as to form a complete
ENT system.

Raceways:
ENT raceway shall be color coded to indicate the wiring system.
Blue stripe for power, red stripe for fire alarm/emergency
systems and yellow stripe for data/communications.
ENT raceway shall be listed to UL1653 and manufactured in
accordance with NEMA TC-13.

Boxes:
ENT boxes shall be manufactured of high impact PVC
ENT slab box and wall box requirements:
• Slab boxes shall be approved for the purpose and
concrete-tight
• Round slab boxes shall be approved for use with
luminaries up to 50 lbs. and ceiling fans up to 35 lbs.
• Round slab boxes shall have threaded brass inserts for
the attachment of luminaries or ceiling fans
• Slab boxes shall have eight (8) integrally molded ENT
hub connectors with six locking tabs for ENT raceway
connection

Installation
ENT raceways, fittings, boxes and accessories shall be
installed in accordance with Article 362 of the 2002 National
Electrical code.
Where ENT penetrates a fire rated wall, floor or ceiling
assembly, an approved firestop system as listed in
Underwriters Laboratories Building Materials Directory or other
nationally recognized testing laboratory shall be used.
Not permitted for use where subject to ambient temperatures
in excess of 122ºF (50ºC).

KWIKON ENT

KWIKON ENT

ENT systems shall be approved for use in fire resistance rated
concrete floor-ceiling assemblies with fire resistance ratings up
to 4 hours.

• When transitioning to EMT conduit, the transition fitting
shall have six locking tabs for ENT connection and setscrew connection for EMT

85

INEXO ® ICF BOX

Full flange prevents box
from twisting and
sinking into foam if
over-tightened

Insertion depth
of 2-1/4"
‘TEETH’ can be
easily removed
and replaced

INEXO provides a 1/2"
drywall setback resulting
in a professional finish

INEXO Boxes for ICF Construction
Until now there have been few choices when attempting to provide a truly
professional electrical box solution for Insulated Concrete Form homes.

‘TEETH’ lock in
place providing a
rigid hold in the
EPS foam

THE INNOVATIVE ELECTRICAL BOX FOR
INSULATED CONCRETE FORM CONSTRUCTION

Residential (NMD Cable 14/2 – 10/3)
Description

Part Number

Product Code

Single Gang

ICF-1-RL

220000

Double Gang

ICF-2-RL

220001

Triple Gang

ICF-3-RL

220002

Commercial (AC or NMD Cable)

INEXO® Electrical Boxes - the only approved
electrical box for ICF construction!

Description

Part Number

Product Code

Single Gang

ICF-1-CLU

220009

Double Gang

ICF-2-CLU

220010

Available in commercial and residential styles.

Triple Gang

ICF-3-CLU

220011

INEXO ICF BOX

Greater installation versatility
with 3 screw hole choices and
flanges on both sides

Single gang box
provides 19 cubic inch
capacity

INEXO’s patented design provides a truly professional solution that
works with your production schedule and provides the quality installation
and finished look that builders require and owners appreciate. INEXO
boxes link seamlessly with existing ICF materials, tools and methods. A
complete offering designed for ICF walls allow builders to standardize
on the use of electrical boxes throughout the building.

NOTES

SUPERDUCT: Telephone, Power &
Communications Duct
Super Duct is recognized by major utilities, contractors and
engineering firms as the premier ducting product available on
the market.
Super Duct is manufactured with a specialized compound and
engineered for high impact and crush strength specifically
required by utilities for underground duct. This compound
enhances the friction coefficient of Super Duct for easier
pulling of conductors/wires through long runs.

UL 651

SUPER DUCT

____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________

87

SUPER DUCT ®

88

ADVANTAGES

89

ENGINEERING DATA

Lightweight

Field Bending

Super Duct is easy to carry and install, reducing labor and costs.

The natural flexibility of IPEX Super Duct allows field
bending, so minor changes in elevation or direction can
often be accommodated without the use of special sweeps or
fittings. The following table indicates typical maximum
offset bends that can be achieved by “cold bending.”

Long Lengths
Super Duct is available in 10' and 20' lengths, minimizing the
number of connections needed.

Bell Ends

Allowable Offset for Super Duct

Super Duct is bell-ended, allowing for easy assembly in the field.

High Compressive Strength
Offset

Super Duct’s specially formulated compound is designed to
withstand high loads.

Low Coefficient of Friction
The smooth bore of Super Duct facilitates cable pulling and
eliminates costly cable damage.

Quality Control
Stringent, continuous testing ensures that Super Duct is a
consistently high quality product.

Size
inches

Max Allowable Offset
10' Length (inches)

Max Allowable Offset
20' Length (inches)

2

20

79

3

14

56

3-1/2

12

49

4

11

43

5

7

35

6

7

29

SUPER DUCT

SUPER DUCT

NOTES:
1. Axial deflection should not be attempted at the joints.
2. The above values were established for ambient temperatures above
the freezing point. Increased radii may be desirable at below-freezing
temperatures.

90

ENGINEERING DATA

Bends

Concrete Encased Monolithic Installation

Pipe Dia.
(in)

91

INSTALLATION

For multipurpose power cable and communication duct banks,
spacing between ducts is critical for optimum performance.
IPEX offers Vertical Lok Spacer systems to accommodate all
specification and field installations.

Radius of Bend (R)
24"

36"

48"

2

90° / 45° / 22-1/2°

3

90° / 45° / 22-1/2°

4

90° / 45° / 22-1/2°

5

90° / 45° / 22-1/2°

6

90° / 45° / 22-1/2°

90°

60"

These lightweight spacers provide the
vertical and horizontal separation required
in a trench.
With spacers in place on trench bottom,
lay the first tier of ducts. When using a
concrete base, lay the bottom tier before
the base has taken initial set. Place
subsequent tiers of spacers on top of the
tier until the required number of ducts are
installed. Then tie the entire assembly
together. It is not necessary to weight or
brace the bank unless the concrete mix is
very wet.

45°

221/2°

The Concrete Pour
Do not allow a heavy mass of concrete to fall directly onto the
duct. If this is a possibility, use a plank to direct the concrete
down the sides of the bank assembly to the trench bottom. The
concrete will flow to the center of the bank and rise up in the
middle, uniformly filling all open spaces. Voids can be
eliminated by carefully working a long, flat slicing bar or
spatula up and down between the vertical rows of ducts.
Concrete should then flow between and under all of the ducts.

Static Friction Coefficient
Ducting Materials PVC
RTRC
.0

.1

.2

.3

.4

.5

.6

.7

.8

Duct Bank Elevation

SUPER DUCT

SUPER DUCT

All spacers should be staggered. It is recommended that
spacers should be located approximately one-fifth of duct
length from each end. Vertical Lok spacers should be located
to a maximum of every 5.5 ft.

Backfilling
Backfill with regular excavated soil after the concrete has set.

92

INSTALLATION

Direct Burial Installation

Concrete Encased Tier-by-Tier
Installation

Trench Bottom

The advantage of this method is the
production of a solid, void-free concrete
envelope. Simply pour each tier
independently.
Cross-section of
tier-by-tier method.

Trench Bottom

After grading the trench, place a foundation of 3" of concrete
on the bottom. It should be smooth and graded.

The trench bottom should provide a
continuous, firm and uniform support
for the duct bank construction. Care
should be taken to avoid lumps, ridges,
depressions and stones causing “point”
contacts or uneven bearing.

Rock or Shale
Excavate 3" below the desired depth and bring the trench back
to grade with selected tamped soil. This will provide the duct
with a uniform bedding surface.

Bank Assembly
Lay the bottom tier of ducts on the
concrete base. Ducts should be spaced
with wooden combs (two per duct
length). Concrete the first tier level to
the top of the comb. Remove combs
and fill the voids. Light tamping will
ensure an even surface. Repeat this
sequence until the bank is built up.

93

INSTALLATION

Unstable Soils
Type of wood comb used.

Tests should be conducted to establish the soil strength in
marshy or swampy areas. It may be necessary in these
conditions to dig deeper and refill with crushed stone or
gravel, or to employ mats, timbers or a concrete base.

Concreting

Placement of Duct

If the concrete is allowed to set before assembling the next
tier, the concrete will be stronger and more dense and the
ducts will be aligned straighter. One problem with this method
is that the bank will be in a series of layers and therefore more
likely to heave and separate under frost conditions. If
successive tiers are laid before the concrete has set, a
satisfactory bond will be achieved by tamping the dry concrete.

After the first tier of ducts is installed, backfill and compact
as outlined below. If wood combs are employed for spacing,
remove them as the backfill is placed and tamped. Then begin
the next tier.

Initial Backfilling
1. Fit side and center to the top of the ducts. Use a hand
tamper only to tamp firmly.

Backfilling
Backfill with regular excavated soil when the bank is complete.

2. Backfill over the duct to the required thickness (see note)
and tamp firmly, using only a hand tamper.

100'
100'
100'
100'

Duct is usually laid in 100' sections once the trench is
excavated. Therefore, concreting can be a continuous process.

When the last tier is placed, hand-place the backfill to 4" over
the duct with soil that does not contain stones larger than
3/8". Hand-tamping of this layer is optional, depending on the
specifications.
From this point, backfill may be completed by hand or by
pneumatic tamping in layers from 4" to 12" depending on the
degree of compaction desired.
When placing backfill by machine, avoid the use of large rocks
until a protective layer (minimum of 12") is established.
Note: In direct burial, no spacer should be used with Duct; spacers provide “point” support
instead of the continuous bed required. Backfill thickness between ducts is usually 2" to 3".

SUPER DUCT

SUPER DUCT

100'

Final Backfilling

94

95

TELEPHONE DUCT

95

POWER & COMMUNICATION DUCT

Telephone Duct

Type EB-20

Type B, Type B(HW), Type C, Type D

Rated For 90°C Cable / 20-Foot Length, Belled One End

Telephone Duct Type B and Type B – Heavy Wall are designed
for use in concrete-encased installations.
Telephone Duct Type C is designed for direct burial applications.
Telephone Duct Type D is designed for exposed and special
applications, and contains 6% titanium oxide for UV resistance.

PVC Telephone Duct 20 foot Length, Belled One End
Nominal Product
Size
Code

Min.
Type Average
OD
Wall

Product
Code

Average
OD

Min. Wall Feet/Pallet Approx.
Wt/lbs

2

008821

2.375

0.060

3,520

37

3

008831

3.500

0.061

1,560

56

*4

008841

4.500

0.082

1,200

93

*5

008851

5.563

0.103

460

142

*6

008861

6.625

0.125

520

202

* UL Listed

Min. Feet / Approx.
ID Pallet lbs/ft

Type DB-60
Rated For 90°C Cable / 20-Foot Length, Belled One End

4

008040

4.350 0.091 4.13 1,260

1.0

4

008041 B (HW) 4.350 0.101 4.11 1,260

1.1

Nominal
Size (in)

Product
Code

Average
OD

4

008042

1.6

2

008321

2.375

0.060

3,520

4

008043 C X 10' 4.350 0.148 4.00

3

008731

3.500

0.092

1,560

80

4

008741

4.500

0.121

1,200

132

5

008751

5.563

0.152

460

202

6

008761

6.625

0.182

520

285

4

008044

B

Nominal
Size (in)

C
D

4.350 0.148 4.00 1,260
630

4.350 0.148 4.00 1,260

1.6
1.6

Min. Wall Feet/Pallet Approx.
Wt/lbs
37

Performance Properties
Type EB-35

As indicated under Telephone Standard 8546

Rated For 90°C Cable / 20-Foot Length, Belled One End
Minimum
Minimum Pipe
Heat Distortion
Impact Resistance
Stiffness
48 hrs @ 140°F
Type @ 73.4ºF @ 32ºF Type lbs/in/in Type Load Max decr.
B

50 ft.lbs.

B(HW) 50 ft.lbs.

25 ft.lbs.

B

25 ft.lbs. B (HW)

30
40

B

15

0.250"

B (HW) 15

0.250"

C

100 ft.lbs. 50 ft.lbs.

C

120

C

60

0.250"

D

150 ft.lbs. 75 ft.lbs.

D

120

D

60

0.250"

Nominal
Size (in)

Product
Code

Average
OD

Min. Wall Feet/Pallet Approx.
Wt/lbs

2

008921

2.375

0.060

3,520

3

008931

3.500

0.076

1,560

64

4

008941

4.500

0.100

1,200

105

5

008951

5.563

0.126

460

161

6

008961

6.625

0.152

520

230

33

Type DB-120 Duct
Nominal
Size (in)

Product
Code

Average
OD

Min. Wall Feet/Pallet Approx.
Wt/lbs

2

008621

2.375

0.077

3,520

3

008631

3.500

0.118

1,560

96

4

008641

4.500

0.154

1,200

158

5

008651

5.563

0.191

460

240

6

008661

6.625

0.227

520

336

PVC Plastic Compounds.
Plastic Utilities Duct for Underground
Installation.
Smooth-Wall Poly (Vinyl-Chloride) (PVC)
ASTM D1784, ASTM F512
conduit and Fittings for Underground
NEMA TC-6
Installation.

42

SUPER DUCT

SUPER DUCT

Rated For 90°C Cable / 20-Foot Length, Belled One End

97

SCEPTACON TM TRENCHLESS RACEWAY SYSTEMS

Visit our website:
www.ipexamerica.com

PRODUCT INFO

TECHNICAL DOCUMENTS

ONLINE TRAINING
&

MUCH MORE ...
SceptaCon Trenchless Raceway Systems
TM

SceptaCon is one of the first PVC systems designed for the
rigors of trenchless applications. It links seamlessly to existing
PVC conduit infrastructures and allows utility companies to
standardize on PVC throughout their entire electrical systems.
SceptaCon's slide-in locking system and pre-installed, prelubricated gaskets allow contractors to create a water-tight seal
by hand in seconds - in all temperatures - without having to
worry about solvents or chemicals freezing or drying too quickly.

DOWNLOAD
OUR ELECTRICAL CATALOG
OR OUR SCEPTER
ELECTRICAL CATALOG

SCEPTACON

+

Its unique spline-lock snaps into a recessed opening, ensuring
the spline won't get snagged during pull-through. SceptaCon's
rounded bell shoulders slide easily past roots, rocks and other
debris in the borehole, ensuring a smooth, easy installation.
And because SceptaCon is made to the same high standards as
our Scepter rigid PVC conduit, contractors and electrical
utilities can be assured of the same level of quality - above
ground and below.

98

SCEPTACON TM TRENCHLESS RACEWAY SYSTEMS

99

KWIKPATH ® COMMUNICATION RACEWAY SYSTEMS

No Cementing or Lubrication
SceptaCon’s slide-in locking system and
pre-installed, pre-lubricated gaskets allow
contractors to create a water-tight seal by
hand in seconds.

Riser / Resi Straps
Manufactured of the same material as
Riser/RESI raceway, Kwikpath pipe straps
allow for compliance with installation requirements providing
for the proper support of Riser/RESI raceways.

Outperforms Other PVC
Products
SceptaCon’s unique spline-lock snaps into
a recessed opening, ensuring the spline
won’t get snagged during pull-through.
SceptaCon’s rounded bell shoulders slide
easily past roots, rocks and other debris in
the borehole, ensuring a smooth, easy
installation.

No Fusion Required
Because SceptaCon’s joints can be quickly
joined by hand in seconds, crews don’t
need large, expensive fusion equipment or
special training to create water-tight joints.
In addition, SceptaCon can be assembled
one pipe length at a time, then pulled
underground, eliminating the need for long
strings of pipe on the job.

132006

1"

KPS100

132007

1-1/4"

KPS125

132008

1-1/2"

KPS150

132009

2"

KPS200

132010

Size (in)

Part Number

Product Code

1/2

CCS10

077794

3/4

CCS15

077796

1

CCS20

077797

1-1/4

CCS25

077798

1-1/2

CCS30

077799

Length

Product Code

2

CCS35

077800

2" x 20'

106221

Strut Base

CCS-B

077343

3" x 10'

106330

3" x 20'

106331

4" x 10'

106340

4" x 20'

106341

5" x 10'

106350

5" x 20'

106351

6" x 10'

106360

6" x 20'

106361

SCEPTACON

SCEPTACON

Product Code

KPS075

The Conduit Clamp and Spacers are
engineered to accommodate proper
expansion and contraction of conduits and
to prevent unwanted clamp opening.

Superior Performance

SceptaCon is available in
convenient 10' and 20'
lengths that are lightweight, easy to handle and
no problem to work with in
all types of weather.

Part Number

3/4"

Conduit Clamp & Spacers

SceptaCon is made from durable schedule 40 PVC that’s
resistant to creasing, scoring or flattening when pulled past
obstructions in the borehole, yet flexible enough to bend with
underground twists and turns. SceptaCon remains round,
unlike HDPE which can stretch and become oval.

Easy to Handle

Size

NOTES

NOTES

____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________

____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________

NOTES

____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________

TYPE
DESIGNATION

1

1
2

UL UNDERWRITERS LABORATORIES INC
(UL 50 AND UL 508)
Indoor use primarily to provide protection
against contact with the enclosed equipment
and against a limited amount of falling dirt.

Register your Pocket Pro today!
Fax this form to (905) 403-1124 and we’ll add
you to our mailing list.

Indoor use to provide a degree of protection
against limited amounts of falling water and dirt.

2

3

Outdoor use to provide a degree of protection
against windblown rain; undamaged by the
formation of ice on the enclosure.

4

Either indoor or outdoor use to provide a
degree of protection against falling rain,
splashing water, and hose-directed water;
undamaged by the formation of ice on the
enclosure.

4X

Either indoor or outdoor use to provide a
degree of protection against falling rain,
splashing water, and hose-directed water;
undamaged by the formation of ice on the
enclosure; resists corrosion.

Tel: (905) 403-0264
Toll Free: (800) 463-9572
Fax: (905) 403-1124

IPEX
2441 Royal Windsor Drive
Mississauga, Ontario, Canada
L5J 4C7

Website: www.ipexamerica.com
PLEASE PRINT

Company

3

Name

4

6P
5

12
13

Indoor or outdoor use primarily to provide a
degree of protection against hose-directed
water, the entry of water during prolonged
submersion at a limited depth, and be
undamaged by the formation of ice on the
enclosure.
Indoor use to provide a degree of protection
against dust, dirt, fiber flyings, dripping water,
and external condensation of noncorrosive
liquids.
Indoor use to provide a degree of protection
and spraying of water, oil, and noncorrosive
liquids.

6
This material is reproduced with permission from Underwriters
Laboratories Inc. Standard for Safety for Cabinets and Boxes, UL
50, Copyright 1988 and Industrial Control Equipment, UL 508,
Copyright 1994 by Underwriters Laboratories Inc.

7

Underwriters Laboratories Inc. (UL) shall not be responsible to
anyone for the use of or reliance upon a UL Standard by anyone.
UL shall not incur any obligation or liability for damages,
including consequential damages, arising out of or in connection
with the use, interpretation of, or reliance upon a UL Standard.

Title
Address
City

State

Zip

Phone

ext.

Fax

E-mail / Website

This is a:
❏ Home Address

❏ Business Address

❏ Jobsite Address

Business Type:
(check 1 or 2 that best apply)

Company Classification:
❏ Distributor/Wholesaler
❏ Engineering Firm
❏ Contractor
❏ Government
❏ OEM - Products Manufactured:_______________________
❏ Other:_____________________________________________
SIC or industry sector:__________________________________
My primary markets are (check all that apply):

8

❏ Commercial
❏ Residential
❏ Industrial
❏ Other:_________________

❏ Utility
❏ OEM
❏ Institutional

CUSTOMER SERVICE CENTER
Customers call IPEX USA LLC
Toll free: (800) 463-9572
www.ipexamerica.com

About the IPEX Group of Companies
As leading suppliers of thermoplastic piping systems, the IPEX Group of
Companies provides our customers with some of the world’s largest and most
comprehensive product lines. All IPEX products are backed by more than
50 years of experience. With state-of-the-art manufacturing facilities and
distribution centers across North America, we have established a reputation
for product innovation, quality, end-user focus and performance.
Markets served by IPEX group products are:
• Electrical systems
• PVC, CPVC, PP, PVCO, ABS, PEX, FR-PVDF and PE pipe and fittings (1/4"
to 48")
• Industrial process piping systems
• Municipal pressure and gravity piping systems
• Plumbing and mechanical piping systems
• PE Electrofusion systems for gas and water
• Industrial, plumbing and electrical cements
• Irrigation systems

Products manufactured by IPEX Electrical Inc. and distributed in the United
States by IPEX USA LLC.
INEXO®, Kwikflex®, Kwikon®, SceptaConTM, SceptalightTM and SuperDuct® are
trademarks of IPEX Branding Inc.

Pocket Pro

DISTRIBUTED BY:

w w w . i p e x a m e r i c a . c o m

E L E C T R I C A L

This literature is published in good faith and is believed to be reliable.
However, it does not represent and/or warrant in any manner the
information and suggestions contained in this brochure. Data presented is
the result of laboratory tests and field experience.

S Y S T E M S

®

TM

TM

Trenchless Raceways Systems

A policy of ongoing product improvement is maintained. This may result
in modifications of features and/or specifications without notice.
®

®

®

®

CTELNAIP130709 © 2013 IPEX EL004U

w w w. i p ex a m e r i c a . c o m



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2013:07:23 09:45:44-04:00
Modify Date                     : 2013:07:23 11:18:55-04:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2013:07:23 11:18:55-04:00
Format                          : application/pdf
Title                           : untitled
Producer                        : Acrobat Distiller 10.1.5 (Windows)
Document ID                     : uuid:261d2597-d2b5-46fe-9086-043158c10bff
Instance ID                     : uuid:f1b2345e-1501-410b-b87c-ad7bdd3ca80f
Page Count                      : 57
EXIF Metadata provided by EXIF.tools

Navigation menu