638059 Catalog

26099-Catalog 26099-Catalog 26099-Catalog 622454 Batch7 unilog cesco-content

2014-09-04

: Pdf 638059-Catalog 638059-Catalog 622454 Batch7 unilog

Open the PDF directly: View PDF PDF.
Page Count: 57

This literature is published in good faith and is believed to be reliable.
However, it does not represent and/or warrant in any manner the
information and suggestions contained in this brochure. Data presented is
the result of laboratory tests and field experience.
A policy of ongoing product improvement is maintained. This may result
in modifications of features and/or specifications without notice.
CTELNAIP130709 © 2013 IPEX EL004U
Customers call
IPEX USA LLC
Toll free: (800) 463-9572
www.ipexamerica.com
CUSTOMER SERVICE CENTER
www.ipexamerica.com
DISTRIBUTED BY:
Products manufactured by IPEX Electrical Inc. and distributed in the United
States by IPEX USA LLC.
INEXO®, Kwikflex®, Kwikon®, SceptaConTM, SceptalightTM and SuperDuct®are
trademarks of IPEX Branding Inc. Pocket Pro
ELECTRICAL SYSTEMS
Trenchless Raceways Systems
® TMTM
®
®
®
www.ipexamerica.com
About the IPEX Group of Companies
As leading suppliers of thermoplastic piping systems, the IPEX Group of
Companies provides our customers with some of the world’s largest and most
comprehensive product lines. All IPEX products are backed by more than
50 years of experience. With state-of-the-art manufacturing facilities and
distribution centers across North America, we have established a reputation
for product innovation, quality, end-user focus and performance.
Markets served by IPEX group products are:
Electrical systems
PVC, CPVC, PP, PVCO, ABS, PEX, FR-PVDF and PE pipe and fittings (1/4"
to 48")
Industrial process piping systems
Municipal pressure and gravity piping systems
Plumbing and mechanical piping systems
PE Electrofusion systems for gas and water
Industrial, plumbing and electrical cements
Irrigation systems
®
Indoor use primarily to provide protection
against contact with the enclosed equipment
and against a limited amount of falling dirt.
Indoor use to provide a degree of protection
against limited amounts of falling water and dirt.
Outdoor use to provide a degree of protection
against windblown rain; undamaged by the
formation of ice on the enclosure.
Either indoor or outdoor use to provide a
degree of protection against falling rain,
splashing water, and hose-directed water;
undamaged by the formation of ice on the
enclosure.
Either indoor or outdoor use to provide a
degree of protection against falling rain,
splashing water, and hose-directed water;
undamaged by the formation of ice on the
enclosure; resists corrosion.
Indoor or outdoor use primarily to provide a
degree of protection against hose-directed
water, the entry of water during prolonged
submersion at a limited depth, and be
undamaged by the formation of ice on the
enclosure.
Indoor use to provide a degree of protection
against dust, dirt, fiber flyings, dripping water,
and external condensation of noncorrosive
liquids.
Indoor use to provide a degree of protection
and spraying of water, oil, and noncorrosive
liquids.
2
3
4
4X
12
13
6P
1 2 3 4 5 6 7 8
1
TYPE
DESIGNATION UL UNDERWRITERS LABORATORIES INC
(UL 50 AND UL 508)
This material is reproduced with permission from Underwriters
Laboratories Inc. Standard for Safety for Cabinets and Boxes, UL
50, Copyright 1988 and Industrial Control Equipment, UL 508,
Copyright 1994 by Underwriters Laboratories Inc.
Underwriters Laboratories Inc. (UL) shall not be responsible to
anyone for the use of or reliance upon a UL Standard by anyone.
UL shall not incur any obligation or liability for damages,
including consequential damages, arising out of or in connection
with the use, interpretation of, or reliance upon a UL Standard.
Company
Name
Title
Address
City State Zip
Phone ext.
Fax E-mail / Website
This is a:
Home Address Business Address Jobsite Address
Business Type:
(check 1 or 2 that best apply)
Company Classification:
Distributor/Wholesaler
Engineering Firm
Contractor
Government
OEM - Products Manufactured:_______________________
Other:_____________________________________________
SIC or industry sector:__________________________________
My primary markets are (check all that apply):
Tel: (905) 403-0264
Toll Free: (800) 463-9572
Fax: (905) 403-1124
Website: www.ipexamerica.com
IPEX
2441 Royal Windsor Drive
Mississauga, Ontario, Canada
L5J 4C7
PLEASE PRINT
Register your Pocket Pro today!
Fax this form to (905) 403-1124 and we’ll add
you to our mailing list.
Commercial
Residential
Industrial
Other:_________________
Utility
OEM
Institutional
i
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . .1
Applications . . . . . . . . . . . . . . . . . . . . . . . . .2
Advantages . . . . . . . . . . . . . . . . . . . . . . . . . .3
Scepter®Rigid PVC Schedule 40 & 80 Conduit .7
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Expansion and Contraction . . . . . . . . . . . . . . . . . .10
Conduit Dimensions . . . . . . . . . . . . . . . . . . . . . . .15
Scepter®PVC Conduit Fittings . . . . . . . . . . . .19
Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Cover Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Weatherproof Covers . . . . . . . . . . . . . . . . . . . . . . .46
Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
Conduit Repair Kit . . . . . . . . . . . . . . . . . . . . .57
EPR Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
SceptalightTM: Nonmetallic Light Fixtures . . . .59
Kwikflex® . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Nonmetallic Liquidtight Flexible Conduit . . . . . . . .67
Nonmetallic Liquidtight Fittings . . . . . . . . . . . . . . .68
Kwikon®ENT . . . . . . . . . . . . . . . . . . . . . . . . .71
ENT Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
Couplings/Connectors . . . . . . . . . . . . . . . . . . . . . .75
Slab Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
ENT Wall Boxes, Ceiling Boxes & Covers . . . . . . . . .81
Short Form Sample Specifications . . . . . . . . . . . . .82
INEXO®ICF Boxes . . . . . . . . . . . . . . . . . . . . .85
....continued
1ii TABLE OF CONTENTS INTRODUCTION
Pocket Pro provides the most comprehensive information about
PVC systems – from basic raw material to installation
characteristics of the finished product. Written with the engineer,
contractor and distributor in mind, it is based on laboratory test
results and IPEX’s many years of field experience.
At IPEX, we have been extruding PVC conduit and molding
fittings since 1951. We formulate our own compounds,
maintain strict quality control during production, and offer one
of the most comprehensive lines of nonmetallic electrical
products throughout North America.
More important, our commitment to customers extends
beyond the sale. Quality control and thorough jobsite field
reports have earned IPEX a reputation for product quality and
service excellence.
Super Duct® . . . . . . . . . . . . . . . . . . . . . . . . .87
Advantages . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
Engineering Data . . . . . . . . . . . . . . . . . . . . . . . . .89
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91
Telephone Duct . . . . . . . . . . . . . . . . . . . . . . . . . .94
Power & Communication Duct . . . . . . . . . . . . . . . .95
SceptaconTM Trenchless Raceway Systems . . .97
32 ADVANTAGES
Labor Savings
Compared to metal, PVC products reduce labor on a typical
installation by up to two-thirds. The reason?
PVC is easy to work with. It can also be cut and joined without
vises, cutters, threading equipment and reamers associated
with metal conduit.
Lightweight Conduit
Scepter rigid PVC conduit is one-half the weight of aluminum
and one-sixth the weight of steel. As a result, handling and
installation are easier and faster, reducing labor costs.
Easy Joining
Solvent cementing is all that is required, eliminating the need
for power-threading machines, pipe vises and cutting
equipment. A hacksaw or carpenter’s saw is the only
equipment required.
Strength
Scepter rigid PVC conduit offers both high impact and high
tensile strength, even in cold temperatures. They exceed all UL
and NEMA standards.
Rigid Conduit Sch. 40 UL Impact @ 73°F
Size (in.) (ft.lbs.)
1/2 50
3/4 80
1 100
1-1/4 120
1-1/2 150
2 190
2-1/2 210
3 – 6 220
APPLICATIONS
Engineers, electricians, contractors, specifiers and utilities have
realized for many years the advantages of PVC. Today, IPEX
electrical systems include Scepter®PVC conduit and fittings,
INEXO®ICF boxes, Kwikon®ENT fittings, SceptaConTM
trenchless raceway systems, SceptalightTM nonmetallic light
fixtures and Super Duct®power and communication ducts.
These brands are the number-one choice for power,
communication and data needs. Whether exposed, concealed in
walls, encased in concrete, or directly buried, IPEX electrical
products are preferred
For The Long Run
.
Only when you specify IPEX branded products by name are you
guaranteed our commitment to excellence.
Applications
Typical industrial/commercial and residential applications for
IPEX electrical systems include:
• Mines
• Steel mills
• Food processing plants
• Subways
• Bridges and tunnels
• Agricultural, dairy, hog, cattle,
chicken, etc.
• Marinas
• Sewage treatment plants
• Pulp & paper industries
• Street and highway lighting
• Car washes
Parking garages
• Residential applications
• Fish plants
• Water treatment plants
• Airports
• Utilities
• Cable
• Communications
54 ADVANTAGES
Fire Resistant
PVC is a self-extinguishing material and will not support
combustion. It will not drip or run when exposed to fire.
Samples taken from an actual fire show the outer surface of
the conduit was blistered and charred.
The interior of the conduit, however, was unaffected.
Additionally, the undamaged conductors were then removed
and reinstalled in new conduit.
Fire-resistant characteristics per CAN ULC S102.2 are as follows:
Suitable for Direct Burial
PVC is suitable for direct burial and
requires no extra protection when installed
in accordance with local inspection
authority guidelines. The usual care
regarding trenches and backfilling should
be respected.
One-Source Specification
IPEX electrical systems offer a full range
of PVC fittings and accessories. As a
result, one-material specifying is possible.
Quality Control
In addition to our rigorous quality control
testing, IPEX product carries third-party
certification by UL and CSA.
IPEX
Compound Flame
Spread Smoke
Developed Fuel
Contribution
1/8" thickness 10 – 20 225 – 270 0
3/4" thickness 10 – 20 300 – 390 0
Easy Wire Pulls
PVC’s exceptionally smooth interior surface greatly reduces the
amount of friction while pulling conductors/wires through long
runs, even with 90° bends. A large pull-rope and wire-pulling
compound should be used when pulling all conductors and wires.
Noncorroding
PVC is immune to damage from naturally
corrosive soil conditions, as well as
electro-chemical and galvanic corrosion.
This ensures lower maintenance costs and
longer performance
For The Long Run.
Nonconducting
IPEX electrical systems are nonsparking
and non-conducting, thereby eliminating
the most dangerous ‘second point of
contact’ and ‘phase to ground’ faults. The
use of a separate grounding conductor
provides complete and positive grounding
for the whole system.
Long Life
Scepter rigid PVC conduit and fittings
retain their original properties after years
of exposure to direct sunlight, heat and
weather. In addition, resistance to fungi,
bacterial action, rodents, termites and
corrosive agents ensures a long, trouble-
free life for PVC conduit installed indoors
or outdoors.
Chemical Resistance
One of the greatest benefits of PVC is its
excellent chemical resistance. It resists
attack by acids, alkalies, salt solutions
and many other types of chemicals.
For more information on PVC and
chemical resistance, refer to the IPEX
Chemical Resistance Guide.
Concrete Tight
Scepter rigid PVC conduit systems are designed and engineered to
be concrete tight in all weather conditions.
ADVANTAGES
7
SCEPTER RIGID
PVC CONDUIT
SCEPTER RIGID PVC SCH. 40 & 80 CONDUIT
This section provides comprehensive information and
guidelines for the design and installation of PVC Schedule 40
& 80 conduit and fittings. Always consult the authority having
jurisdiction for specific installation procedures.
UL Listed-UL651
Sunlight Resistant
Rated for use with 90°C
conductors
NEMA TC-2
Corps. of Engineers Spec.
CE 303:01
Military Spec,Federal Spec.
WC 09A
Bookmark Our Website
www.ipexamerica.com
OUR ELECTRICAL CATALOG
& SCEPTER ELECTRICAL
CATALOG INCLUDE MORE
INFORMATION ON:
Conduit & Fittings Duct
Light Fixtures Trenchless Raceways
ENT Tubing & Fittings and much more ...
PRODUCT INFO,
TECHNICAL
DOCUMENTS,
ONLINE TRAINING
& MUCH MORE ...
available at www.ipexamerica.com
98
SCEPTER RIGID
PVC CONDUIT
SCEPTER RIGID
PVC CONDUIT
INSTALLATION
Solvent Cementing
After cutting Scepter rigid PVC conduit,
sharp edges or burrs from inside the
conduit should be removed with a knife.
Thoroughly clean the end of the pipe
and inside the fitting with a pipe
cleaner. Apply a generous amount of
solvent cement to both surfaces; slide
together and give a quarter turn to
ensure the solvent is spread evenly on
the material. Hold together for a few
seconds until the joint is made.
Usually the solvent-cemented joint will
be strong enough to install immediately.
However, in climates with low
temperatures or areas with high humidity, extra time may be
required before moving the pipe for permanent installation.
Solvent cemented joints appear to “set up” instantly, but will
take 24 hours to cure properly. After this time, the solvent-
cemented joint has completely cured and is waterproof. For
extreme cold weather installations, a PVC primer is
recommended. IPEX cements and primers are available in
quarter-pint, half-pint, pint, quart and gallon containers.
Bending
PVC is a thermoplastic material that,
when heated, becomes soft and pliable.
As a result, its shape can be altered.
A flameless heat source is
recommended to heat the pipe. AN
OPEN FLAME SHOULD NOT BE USED.
Either an electric unit or an infra-red
propane unit is recommended.
The necessary temperature for bending
pipe is 260°F. The pipe must be heated
evenly over an area approximately ten
times the diameter of the pipe before
any attempt at bending is made.
Bending the pipe when it has not been
thoroughly heated will cause the pipe to
“kink.” With proper care and a little
practice, the bend will form easily.
Cooling the pipe with cold air or water
will cause “spring back.” Allow a few
extra degrees of overbending to
compensate. Maximum bending radius
shall be six times the internal diameter
according to NEC.
Support
Due to PVC’s light weight,
support spacing is different
than that used with metal
conduits. Supporting straps should
NOT be firmly tightened, to allow for
linear movement. The maximum
allowable support spacing, as per National Electrical
Code Article 352.30 (NEC), is as follows:
Support Spacing For Schedule 40 & 80
Conduit
Maximum Operating
Temperature
The National Electrical Code (NEC)
permits the use of rigid PVC pipe and
fittings in areas where ambient
temperatures do not exceed 122°F.
Cutting
Scepter rigid PVC conduit can be easily
cut on the jobsite by using a hacksaw,
carpenter’s saw or PVC conduit cutters.
For larger sizes of conduit, the use of a
miter box is also recommended to ensure
a square cut.
INSTALLATION
Nominal Conduit Diameter Maximum Support Spacing
inches feet
1/2 3
3/4 3
1 3
1-1/4 5
1-1/2 5
2 5
2-1/2 6
3 6
3-1/2 7
4 7
5 7
6 8
1110
SCEPTER RIGID
PVC CONDUIT
SCEPTER RIGID
PVC CONDUIT
EXPANSION & CONTRACTION
Number of Expansion Joints Required
Use the following equation to determine the number of expansion
joints needed for a Scepter Rigid PVC Conduit installation:
Number of joints =
E = Expansion joint travel length (4") or (8") depending on diameter.
Always round up to the next whole number.
Setting the Piston Opening
The expansion joint must be installed to allow for expansion and
contraction of the conduit run. On a cold day, if an expansion joint is
installed completely closed with the piston bottomed, there is no room
for expansion when the conduit is warmed. If it is installed open to the
maximum on a hot day, the expansion joint will pull apart when cooled.
The correct piston opening for any installation condition can be easily
determined using the formula below:
Piston setting =
Compressed length + max. temp. – installation temp. x E
max. temp. – min. temp.
Formula can be used for both metric and imperial measurements.
total expansion (in)
E
Size (inches) Compressed Length (inches) Travel (inches)
1/2 8.00 4
3/4 8.00 4
18.50 4
1-1/4 9.00 4
1-1/2 9.00 4
29.25 4
2-1/2 9.25 4
314.25 8
3-1/2 14.25 8
414.25 8
514.25 8
614.25 8
()
EXPANSION & CONTRACTION
Using Expansion Joints
It’s just as important to know when to
use an expansion joint as it is to know
how to install it correctly. Expansion
joints are required when the
temperature change is greater than
25°F. Scepter rigid PVC conduit has a
coefficient of linear expansion of 3.6 x
10-4 in./ft./°F. Generally, a 100 ft. run
of PVC conduit will undergo a change in
length of 3.6 inches for every 100°F
temperature change.
For conduit installed indoors, the range of expansion and
contraction can be calculated using the maximum air
temperature plus the heat contributed by the conductors inside
the conduit and minimum air temperature expected. Expansion
joints are not required indoors unless there are widely varying
temperatures such as the attic of a building.
Conduit installed outdoors, exposed to direct sunlight, will be
considerably hotter than the air temperature. As a guideline in
this case, add 27°F to the temperature change. Expansion
joints should be installed to allow for the anticipated
temperature change.
Expansion Formula
By using the following formula and the chart below, the total
expected expansion in a run can be easily determined:
Total Expansion (in.) = length of run (ft.)
x temperature change (°F) x 0.00036
0 1 2 3 4 5
120
110
100
90
80
70
60
50
40
30
20
10
PVC PIPE
As a general rule
for every
temperature
change of 10ºF,
PVC pipe will
expand or contract
3/8" per 100'
TEMPERATURE CHANGE IN ºF
LENGTH VARIATION in/100 ft OF PIPE
PVC PIPE LENGTH VARIATION
DUE TO TEMPERATURE CHANGE (ºF)
Coefficient = 3.6 x 10-4 in/ft/ºF
1312
SCEPTER RIGID
PVC CONDUIT
SCEPTER RIGID
PVC CONDUIT
EXPANSION & CONTRACTION
Figure 1
Figure 2
Figure 3
Figure 4
EXPANSION & CONTRACTION
Location of Expansion Joints
Proper functioning of an expansion joint depends on three
procedures:
1. The correct placement of the expansion joint.
2. The proper installation of Scepter rigid PVC conduit and the
expansion joint.
3. The proper placement and fastening of support straps.
One Expansion Joint
Figure 1
If only one expansion joint is needed between two boxes, the
barrel of the joint should be rigidly fastened close to the
first box. Scepter rigid PVC conduit is then loosely supported
with straps, allowing the conduit to move freely as it
expands and contracts.
Two Expansion
Joints
Figure 2
If two expansion joints
are needed, the joints are
firmly fastened back to back
at the center of the run.
Scepter rigid PVC conduit is
loosely supported with straps, allowing the
conduit to move freely as it expands and
contracts.
Two Expansion Joints (Alternative)
Figure 3
Alternatively, the center of the run and the two expansion joints
(located at the boxes) should be rigidly fastened. All other
support straps should be loosely fastened.
Three or More Expansion Joints
Figure 4
If more than two joints are needed in a very long run, they
should be put in a series, one after the other. Each barrel must
be rigidly fastened while conduit is loosely supported with
straps allowing conduit to move freely as it expands and
contracts. When installed in a series, each section acts
independently of the other. Spacing of conduit supports must
be in accordance with the NEC Article 352.30.
1514
SCEPTER RIGID
PVC CONDUIT
SCEPTER RIGID
PVC CONDUIT
Weight Comparison of Scepter Rigid PVC
Conduit (lbs./100 ft.)
CONDUIT DIMENSIONS
Scepter PVC Schedule 40 in 10' or 20' Lengths
Scepter PVC Schedule 40 conduit is listed with Underwriters
Laboratories Inc. Article 352 of the National Electrical Code
outlines the correct installation procedures.
UL Listed-UL651
Sunlight Resistant
Rated for use with 90°C
conductors
NEMA TC-2
Corps. of Engineers Spec.
CE 303:01
Military Spec, Federal Spec.
WC 1094A
Nominal
Size
(in)
10'
Product
Code
20'
Product
Code Code
OD (in) ID (in) Min.
Wall
(in)
Weight
lbs/100
ft
Standard
10'
ft/crate
1/2 032405 032406 0.840 0.622 0.109 15 6,000
3/4 032407 032408 1.050 0.824 0.113 21 4,400
1032410 032411 1.315 1.049 0.133 31 3,600
1-1/4 032412 032414 1.660 1.380 0.140 42 3,300
1-1/2 032415 032416 1.900 1.610 0.145 53 2,250
2032420 032421 2.375 2.067 0.154 71 1,400
2-1/2 032425 032426 2.875 2.469 0.203 112 930
3032430 032431 3.500 3.068 0.216 166 880
3-1/2 032435 032436 4.000 3.548 0.226 200 630
4032440 032441 4.500 4.026 0.237 236 570
5032450 032451 5.563 5.047 0.258 321 380
6032460 032461 6.625 6.065 0.280 417 260
Nominal Size (in) Schedule 40 PVC Aluminum Rigid Steel
1/2 15 28 79
3/4 21 36 105
131 53 153
1-1/4 42 70 201
1-1/2 53 86 249
271 116 334
2-1/2 112 183 527
3166 239 690
3-1/2 200 288 831
4236 340 982
5321 465 1,334
6417 613 1,771
EXPANSION & CONTRACTION
Common Mistakes
The most common mistakes are neglecting to use
expansion joints or not using enough expansion joints. It
is more cost effective to use more expansion joints than
needed, rather than too few. It is difficult to correct the
problem after conductors are installed and in service.
Another common mistake is to tighten the support straps
too firmly. This will not allow for the proper expansion and
contraction of rigid PVC conduit.
1. Solvent cement the PVC conduit into the conduit hub of
the OPEJ and firmly secure the PVC conduit on the
solvent cement side of the OPEJ using IPEX pipe straps.
2. Set the expansion fitting by marking a line 11/2" from the
end of the conduit to be inserted and insert the conduit
into the OPEJ to this mark.
3. Secure and support the conduit raceway using IPEX
pipe straps.
Installation of the One Piece
Expansion Joint (OPEJ)
Installation of Expansion Joints
Installation recommendations:
• Expansion joints should be mounted so the piston can
travel in a straight line in the barrel. If the alignment is not
straight, the piston will bind, preventing the joint from
working correctly.
• The expansion joint barrel should be clamped tight, but the
conduit mounted loose enough in its hangers to allow for
movement as it expands and contracts.
• Scepter nonmetallic straps are correctly sized and designed
for proper support, and must be used to secure the conduit.
• When expansion joints are used in a vertical position, the
piston should be in a downward position so dirt cannot
deposit between the barrel and piston at the muzzle of the
expansion joints.
WARNING:
16
SCEPTER RIGID
PVC CONDUIT
SCEPTER RIGID
PVC CONDUIT
CONDUIT DIMENSIONS
Scepter Schedule 80 Heavy Wall in 10' or
20' Lengths
Scepter PVC Heavy Wall conduit is for use above and below
ground where it may be subject to severe physical damage, such
as pole risers, bridge crossings and other similar applications.
UL Listed-UL651
Sunlight Resistant
Rated for use with 90°C
conductors
NEMA TC2
Corps. of Engineers Spec.
CE 303:01
Military Spec, Federal Spec.
WC 1094A
Nominal
Size (in) 10'
Product
Code
20'
Product
Code OD (in) ID (in) Min.
Wall
(in)
Weight
lbs/100
ft
Standard
10'
ft/crate
1/2 032505 032506 0.840 0.546 0.147 21 6,000
3/4 032507 032508 1.050 0.724 0.154 28 4,400
1032510 032511 1.315 0.957 0.179 41 3,600
1-1/4 032512 032514 1.660 1.278 0.191 57 3,300
1-1/2 032515 032516 1.900 1.500 0.200 70 2,250
2032520 032521 2.375 1.939 0.218 96 1,400
2-1/2 032525 032526 2.875 2.323 0.276 146 930
3032530 032531 3.500 2.900 0.300 195 880
4032540 032541 4.500 3.826 0.337 286 570
5032550 032551 5.563 4.813 0.375 397 380
6032560 032561 6.625 5.761 0.432 546 260
Weight Comparison of Scepter Rigid PVC
Conduit (lbs./100 ft.)
Nominal Size (in) Schedule 80 PVC Aluminum Rigid Steel
1/2 21 28 79
3/4 28 36 105
141 53 153
1 1/4 57 70 201
1 1/2 70 86 249
296 116 334
2 1/2 146 183 527
3195 239 690
4286 340 982
5397 466 1,334
6546 613 1,771
17
CONDUIT DIMENSIONS
PROPERTIES UNIT VALUE ASTM
TEST
METHOD
ELECTRICAL
Dielectric Strength volts/mil 1215 D149
Dielectric Constant 60 cps at 30ºC 3.55 D150
1000 cps at
30ºC 3.22 D150
Power Factor 60 cps at 30ºC 4.04 D150
1000 cps at
30ºC 4.71 D150
PHYSICAL
Specific Gravity 13.5 D792
Hardness Durometer D 78 D676
Izod Impact Strength
@ 73ºF (23ºC) ft.lb/in. notch 15.0 D256
Tensile Strength
@ 73ºF (23ºC) psi 6000 D638
Compressive Strength psi 8600 D695
Flexural Strength psi 11500 D790
THERMAL
Coefficient of Thermal
Conductivity BTU/sec/in2/ºF/in 0.11 C177
Coefficient of Linear
Expansion per ºF x 10-5 5.5 D696
Heat Distortion
Temperature at 264 psi ºF 158 D648
OTHERS
Flammability self-
extinguishing D635
Water Absorption in 30
days %0.6
Color charcoal grey
Light Transmission opaque D791
PHYSICAL PROPERTIES OF PVC TYPE II
All technical data is believed to be accurate and is presented soley
for information and guidance.
SCEPTER CONDUIT
FITTINGS
19
PVC CONDUIT FITTINGS
Industry leaders specify Scepter PVC conduit fittings by
name. For years, Scepter PVC fittings have set the standard
for quality and value-added features not normally available
from other suppliers. Features such as our threaded brass
inserts, brass screws and superior PVC gasketing system
make a real difference.
It’s our Commitment to Excellence.
UL Listed
UL514B - UL514C NEMA TC-2, 3
UL651
C22.2 No. 85
NOTES
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
2120
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
FITTINGS
Long Line Couplings
Size (inches) Part Number Product Code A (inches)
1-1/2 LLC30 077192 3.175
2LLC35 077193 3.675
2-1/2 LLC40 077194 4.280
3LLC45 077195 4.800
4 LLC55 077196 6.200
5LLC60 077197 8.220
6 LLC65 077198 8.220
Size (inches) Part Number Product Code L (inches)
2 x 1-1/4 SW3525 077320 4
3 x 2 SW4535 077321 6
3 x 2-1/2 SW4540 077335 6.5
4 x 2 SW5535 077322 7
4 x 2-1/2 SW5540 069282 -
4 x 3 SW5545 077333 7
(Socket x Socket) Other sizes available upon request.
Fabricated Swedge Reducer Couplings
Repair Coupling Sleeve
Size
(inches) Part
Number Product
Code A (inches) D Min
(inches) D Max
(inches)
1-1/2 REC30 077292 2.300 1.912 1.924
2REC35 077293 2.405 2.367 2.399
2-1/2 REC40 077294 3.450 2.883 2.897
3REC45 077295 3.600 3.507 3.523
4 REC55 077296 3.920 4.506 4.524
5REC60 077297 4.275 5.583 5.603
6 REC65 077298 4.620 6.647 6.669
D
A
FITTINGS
Couplings
Size (in) Part
Number Product
Code A (in) B (in) C (in)
1/2 EC10 068000 1.060 0.844 1.400
3/4 EC15 068001 1.310 1.056 1.640
1EC20 077003 1.590 1.315 2.031
1-1/4 EC25 077004 2.000 1.660 2.156
1-1/2 EC30 077005 2.230 1.900 2.281
2EC35 077006 2.720 2.375 2.406
2-1/2 EC40 077007 3.320 2.875 3.187
3EC45 077008 4.000 3.500 3.437
3-1/2 EC50 077009 4.500 4.000 3.625
4EC55 077010 5.000 4.500 3.750
5EC60 077011 6.120 5.563 4.187
6EC65 077012 7.370 6.625 4.562
5º couplings
Size (inches) Part Number Product Code L (inches)
25EC35 077100 4.0
2-1/2 5EC40 077101 5.5
35EC45 077103 6.0
3-1/2 5EC50 077102 7.0
45EC55 077104 7.0
55EC60 077105 7.5
65EC65 077106 11.0
2322
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
FITTINGS
Reducer Bushings
Size (in) Part Number Product Code
3/4 x 1/2 1805 077300
1 x 1/2 1805-1 077301
1 x 3/4 1806 077302
1-1/4 x 3/4 1807-1 077303
1-1/4 x 1 1807 077304
1-1/2 x 1 1808-1 077305
1-1/2 x 1-1/4 1808 077306
2 x 1 1809-1 077313
2 x 1-1/4 1809 077307
2 x 1-1/2 1810 077308
2-1/2 x 2 1811 077309
3 x 2 1812-1 077310
3 x 2-1/2 1812 077311
4 x 2 1813-1 077319
4 x 3 1813 077312
4 x 3-1/2 1814 077317
*Additional sizes of reducer bushings are available upon request.
Threaded Reducer Bushings
Size (in) Part Number Product Code
3/4 x 1/2 1825 077314
1 x 1/2 1826 077315
1 x 3/4 1827 077316
Female Adapters
Note: All female adapters have NPT-tapered threads.
Size (in) Part
Number Product
Code A (in) B (in) C (in) D (in)
1/2 FA10 076544 0.620 1.080 0.800 1.725
1/2 FA10 077041 0.620 1.080 0.800 1.725
3/4 FA15 077042 0.820 1.300 0.800 1.900
1FA20 077043 1.065 1.590 1.000 2.300
1-1/4 FA25 077044 1.395 2.000 1.015 2.425
1-1/2 FA30 077045 1.575 2.230 1.050 2.440
2FA35 077046 2.050 2.720 1.075 2.550
2-1/2 FA40 077047 1.020 3.250 1.500 2.700
3FA45 077048 3.090 4.000 1.630 4.100
3-1/2 FA50 077049 3.540 4.500 1.800 3.895
4FA55 077050 4.025 5.000 1.755 4.210
5FA60 077051 5.035 6.120 2.065 5.240
6FA65 077052 6.045 7.370 2.065 5.235
Terminal Adapters
Size (in) Part
Number Product
Code A (in) B (in) C (in) D (in)
1/2 TA10 077021 0.700 0.591 0.750 1.550
3/4 TA15 077022 0.675 0.790 1.000 1.750
1TA20 077023 0.625 1.000 1.115 1.860
1-1/4 TA25 077024 0.640 1.311 1.300 2.125
1-1/2 TA30 077025 0.725 1.530 1.425 2.250
2TA35 077026 0.800 1.970 1.150 2.100
2-1/2 TA40 077027 0.800 2.346 1.900 2.930
3TA45 077028 0.815 2.915 2.000 3.055
3-1/2 TA50 077029 1.000 3.385 1.715 3.055
4TA55 077030 0.815 3.850 1.990 3.215
5TA60 077031 1.725 5.015 2.000 5.985
6TA65 077032 1.875 6.025 2.130 6.500
Note: 1/2" to 1 1/4" TA - tapered thread
1 1/2" to 6" TA - non-tapered thread
FITTINGS
2524
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
FITTINGS
Poly Plugs
Size (in) Part Number Product Code
2 - 2-1/2 PP3540 077433
3 - 3-1/2 PP4550 077434
4PP55 077435
5PP60 077436
6PP65 077437
“O” Ring Expansion Joints
Size (in) Part Number Product Code A (in) B (in)
1/2 EJ10 077381 12.00 8.00
3/4 EJ15 077382 12.00 8.00
1EJ20 077383 12.50 8.50
1-1/4 EJ25 077384 13.00 9.00
1-1/2 EJ30 077385 13.00 9.00
2EJ35 077386 13.25 9.25
2-1/2 EJ40 077387 13.25 9.25
3EJ45 077388 22.25 14.25
3-1/2 EJ50 077389 22.25 14.25
4EJ55 077390 22.25 14.25
5EJ60 077391 22.25 14.25
6EJ65 077392 22.25 14.25
AB
max. min.
FITTINGS
End Bells
Size (in) Part Number Product Code
1/2 EB-10 077406
3/4 EB-15 077085
1EB-20 077323
1-1/4 EB-25 077324
1-1/2 EB-30 077325
2EB-35 077326
2-1/2 EB-40 077327
3EB-45 077328
3-1/2 EB-50 077329
4EB-55 077330
5EB-60 077331
6EB-65 077332
End Caps
Size (in) Part Number Product Code
1/2 CAP10 077421
3/4 CAP15 077422
1CAP20 077423
1-1/4 CAP25 077424
1-1/2 CAP30 077425
2CAP35 077426
2-1/2 CAP40 077427
3CAP45 077428
3-1/2 CAP50 077429
4CAP55 077430
5CAP60 077431
6CAP65 077432
2726
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
FITTINGS
90° Elbows
Schedule 40
Standard Radius
FITTINGS
One Piece Expansion Joints
Size (in) Part Number Product Code
1/2 OPEJ10 077018
3/4 OPEJ15 077019
1OPEJ20 077053
1-1/4 OPEJ25 077054
1-1/2 OPEJ30 077061
2OPEJ35 077063
T.A. Special Expansion Joint
Size (in) Part Number Product Code
2-1/2 EJ40TA 077398
Expansion and Deflection Fitting Assemblies
Size (in) Part Number Description Product Code
2* SE-J-35 Complete Assembly 077889
3* SE-J-45 Complete Assembly 077890
4* SE-J-55 Complete Assembly 077891
Size
inches Part
Number Product
Code D
inches T
inches R
inches
1/2 EE1090 068580 0.840 1.500 4.00
3/4 EE1590 068581 1.050 1.500 4.50
1EE2090 068582 1.315 1.875 5.75
1-1/4 EE2590 068583 1.660 2.000 7.25
1-1/2 EE3090 068584 1.900 2.000 8.25
2EE3590 068585 2.375 2.000 9.50
2-1/2 EE4090 068586 2.875 3.000 10.50
3EE4590 068587 3.500 3.125 13.00
3-1/2 EE5090 068588 4.000 3.250 15.00
4EE5590 068589 4.500 3.375 16.00
5EE6090 068591 5.563 3.625 24.00
6EE6590 068592 6.625 3.750 30.00
45° Elbows
Schedule 40
Standard Radius
Size
inches Part
Number Product
Code D
inches T
inches R
inches
1/2 EE1045 068600 0.840 1.500 4.00
3/4 EE1545 068601 1.050 1.500 4.50
1EE2045 068602 1.315 1.875 5.75
1-1/4 EE2545 068603 1.660 2.000 7.25
1-1/2 EE3045 068604 1.900 2.000 8.25
2EE3545 068605 2.375 2.000 9.50
2-1/2 EE4045 068606 2.875 3.000 10.50
3EE4545 068607 3.500 3.125 13.00
3-1/2 EE5045 068608 4.000 3.250 15.00
4EE5545 068609 4.500 3.375 16.00
5EE6045 068611 5.563 3.625 24.00
6EE6545 068612 6.625 3.750 30.00
* Not Certified
28 FITTINGS 29
FITTINGS
30° Elbows
Schedule 40
Standard Radius
Size
inches Part
Number Product
Code D
inches T
inches R
inches
1/2 EE1030 068620 0.840 1.500 4.00
3/4 EE1530 068621 1.050 1.500 4.50
1EE2030 068622 1.315 1.875 5.75
1-1/4 EE2530 068623 1.660 2.000 7.25
1-1/2 EE3030 068624 1.900 2.000 8.25
2EE3530 068625 2.375 2.000 9.50
2-1/2 EE4030 068626 2.750 3.000 10.50
3EE4530 068627 3.500 3.125 13.00
3-1/2 EE5030 068628 4.000 3.250 15.00
4EE5530 068629 4.500 3.375 16.00
5EE6030 068631 5.563 3.625 24.00
6EE6530 068632 6.625 3.750 30.00
22-1/2° Elbows
Schedule 40
Standard Radius
Size
inches Part
Number Product
Code D
inches T
inches R
inches
1-1/2 EE1522 078580 1.900 2.000 8.25
2EE2022 078581 2.375 2.000 9.50
2-1/2 EE2522 078582 2.875 3.000 10.50
3EE3022 078583 3.500 3.125 13.00
3-1/2 EE3522 078584 4.000 3.250 15.00
4EE4022 078585 4.500 3.375 16.00
5EE5022 078586 5.563 3.625 24.00
6EE6022 078587 6.625 3.750 30.00
90° Elbows
Schedule 40
Integral Bell End
Size
inches Part
Number Product
Code D
inches T
inches R
inches
1/2 EE1090B 068420 0.840 1.500 4.00
3/4 EE1590B 068421 1.050 1.500 4.50
1EE2090B 068422 1.315 1.875 5.75
1-1/4 EE2590B 068423 1.660 2.000 7.25
1-1/2 EE3090B 068424 1.900 2.000 8.25
2EE3590B 068425 2.375 2.000 9.50
2-1/2 EE4090B 068426 2.875 3.000 10.50
3EE4590B 068427 3.500 3.125 13.00
3-1/2 EE5090B 068428 4.000 3.250 15.00
4EE5590B 068429 4.500 3.375 16.00
5EE6090B 068430 5.563 3.625 24.00
6EE6590B 068431 6.625 3.750 30.00
45° Elbows
Schedule 40
Integral Bell End
Size
inches Part
Number Product
Code D
inches T
inches R
inches
1/2 EE1045B 068561 0.840 1.500 4.00
3/4 EE1545B 068562 1.050 1.500 4.50
1EE2045B 068563 1.315 1.875 5.75
1-1/4 EE2545B 068564 1.660 2.000 7.25
1-1/2 EE3045B 068565 1.900 2.000 8.25
2EE3545B 068566 2.375 2.000 9.50
2-1/2 EE4045B 068567 2.875 3.000 10.50
3EE4545B 068568 3.500 3.125 13.00
3-1/2 EE5045B 068569 4.000 3.250 15.00
4EE5545B 068570 4.500 3.375 16.00
5EE6045B 068571 5.563 3.625 24.00
6EE6545B 068572 6.625 3.750 30.00
D
T
R
D
T
R
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
90° Elbows
Schedule 80
Standard Radius
Size
inches Part
Number Product
Code D
inches T
inches R
inches
1/2 80EE1090 068690 0.840 1.500 4.00
3/4 80EE1590 068691 1.050 1.500 4.50
180EE2090 068692 1.315 1.875 5.75
1-1/4 80EE2590 068693 1.660 2.000 7.25
1-1/2 80EE3090 068694 1.900 2.000 8.25
280EE3590 068695 2.375 2.000 9.50
2-1/2 80EE4090 068696 2.875 3.000 10.50
380EE4590 068697 3.500 3.125 13.00
480EE5590 068698 4.500 3.375 16.00
580EE6090 068699 5.563 3.625 24.00
680EE6590 068700 6.625 3.750 30.00
30° Elbows
Schedule 80
Standard Radius
Size
inches Part
Number Product
Code D
inches T
inches R
inches
1/2 80EE1030 068550 0.840 1.500 4.00
3/4 80EE1530 068551 1.050 1.500 4.50
180EE2030 068552 1.315 1.875 5.75
1-1/4 80EE2530 068553 1.660 2.000 7.25
1-1/2 80EE3030 068554 1.900 2.000 8.25
280EE3530 068555 2.375 2.000 9.50
2-1/2 80EE4030 068556 2.750 3.000 10.50
380EE4530 068557 3.500 3.125 13.00
480EE5530 068558 4.500 3.375 16.00
580EE6030 068559 5.563 3.625 24.00
680EE6530 068560 6.625 3.750 30.00
45° Elbows
Schedule 80
Standard Radius
Size
inches Part
Number Product
Code D
inches T
inches R
inches
1/2 80EE1045 068810 0.840 1.500 4.00
3/4 80EE1545 068811 1.050 1.500 4.50
180EE2045 068812 1.315 1.875 5.75
1-1/4 80EE2545 068813 1.660 2.000 7.25
1-1/2 80EE3045 068814 1.900 2.000 8.25
280EE3545 068815 2.375 2.000 9.50
2-1/2 80EE4045 068816 2.875 3.000 10.50
380EE4545 068817 3.500 3.125 13.00
480EE5545 068818 4.500 3.375 16.00
580EE6045 068819 5.563 3.625 24.00
680EE6545 068820 6.625 3.750 30.00
30 FITTINGS 31
FITTINGS
D
T
R
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
32 FITTINGS 33
FITTINGS
Schedule 40 Special Radius (Plain End)
Size
Inches Degree Bend 18" Radius
Product Code 24" Radius
Product Code 30" Radius
Product Code 36" Radius
Product Code 48" Radius
Product Code 60" Radius
Product Code
1
90 068702 068722 068742 068762 068782 #
45 068802 068822 068842 068862 068882 #
30 068902 068922 068942 068962 068982 #
22-1/2 078853 078035 ####
1-1/4
90 068703 068723 068743 068763 068783 #
45 068803 068823 068843 068863 068883 #
30 068903 068923 068943 068963 068983 #
22-1/2 068513 078667 # # # #
1-1/2
90 068704 068724 068744 068764 068784 #
45 068804 068824 068844 068864 068884 #
30 068904 068924 068944 068964 068984 #
22-1/2 068523 078668 ####
2
90 068705 068725 068745 068765 068785 068113
45 068805 068825 068845 068865 068885 #
30 068905 068925 068945 068965 068985 #
22-1/2 068514 068547 #068515 # #
2-1/2
90 068706 068726 068746 068766 068786 #
45 068806 068826 068846 068866 068886 #
30 068906 068926 068946 068966 068986 #
22-1/2 068524 ####
3
90 068707 068727 068747 068767 068787 068114
45 068807 068827 068847 068867 068887 #
30 068907 068927 068947 068967 068987 #
22-1/2 068516 068525 #068517 068526 #
3-1/2
90 Use Standard
Schedule 40
Elbow
068728 068748 068768 068788 #
45 068828 068848 068868 068888 #
30 068928 068948 068968 068988 #
22-1/2 068130 ####
4
90 Use Standard
Schedule 40
Elbow
068729 068749 068769 068789 068112
45 068829 068849 068869 068889 078011
30 068929 068949 068969 068989 #
22-1/2 068518 068519 068520 068521 068111
5
90 Use Standard
Schedule 40 Elbow
068751 068771 068791 068115
45 068851 068871 068891 078615
30 068951 068971 068991 068132
22-1/2 068529 068522 # #
6
90 Use Standard
Schedule 40 Elbow
068772 068792 #
45 068872 068892 078220
30 068972 068992 #
22-1/2 068528 068527 078221
8
90 - - - - 068052 #
45 - - - - 068082 #
22-1/2 - - - - 068081 #
11-1/4 - - - - 068080 #
Note: # indicates available on request. Material is
non-cancelable and non-returnable.Note: Larger Radius Elbows are available on request
and are non-cancelable and non-returnable.
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
3534 FITTINGS
Schedule 40 Special Radius (Belled One End)
Size
Inches Degree Bend 18" Radius
Product Code 24" Radius
Product Code 36" Radius
Product Code 48" Radius
Product Code
290 068014 068030 068054 068078
45 068015 068033 068055 068079
2-1/2 90 068016 068034 068056 068086
45 068017 068035 068057 068090
390 068018 068036 068058 068091
45 068019 068037 068059 068092
3-1/2 90 Use Std. Sch. 40
Radius (15") 068038 068070 068093
45 068039 068071 068094
490 Use Std. Sch. 40
Radius (16") 068050 068072 068095
45 068053 068073 068096
590 Use Std. Sch. 40
Radius (24") Use Std. Sch. 40
Radius (24") 068074 068097
45 068075 068098
690 Use Std. Sch. 40
Radius (30") Use Std. Sch. 40
Radius (30") 068076 068099
45 068077 068106
Schedule 80 Special Radius (Belled One End)
Size
Inches Degree
Bend 18" Radius
Product Code 24" Radius
Product Code 30" Radius
Product Code 36" Radius
Product Code 48" Radius
Product Code
190 068710 # # # 068541
45 # # # # #
1-1/4 90 068711 068735 # # 068542
45 # # # # #
1-1/2 90 068712 # # 068545 068543
45 # # # # #
290 068713 068736 #068775 068544
45 #068530 #068534 #
2-1/2 90 068714 068737 # 068776 068548
45 # 068531 # 068535 #
390 068715 068738 #068777 068794
45 #068532 #068536 #
490 068716 068739 068549 068778 068795
45 # 068533 # 068537 #
590 Use Standard Schedule 80 Radius (24") #068779 068796
45 #068538 068546
690 068540 068797
45 068539 #
Note: # indicates available on request. Material is non-
cancelable and non-returnable.Note: 30º and 22½º Elbows are available on request.
Note: Larger Radius Elbows are available on request and
are non-cancelable and non-returnable.
FITTINGS
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
3736
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
FITTINGS
Conduit Clamps and Spacers
Size (in) Part Number Product Code
1/2 CCS10 077794
3/4 CCS15 077796
1CCS20 077797
1-1/4 CCS25 077798
1-1/2 CCS30 077799
2CCS35 077800
Strut Base CCS-B 077343
CCS-B are sold individually, two pieces are required to create one
base unit.
PVC Coated Steel, 1 Hole
Size (in) Part Number Product Code
1/2 CS10-1 077831
3/4 CS15-1 077832
1CS20-1 077833
1-1/4 CS25-1 077834
1-1/2 CS30-1 077835
2CS35-1 077836
2-1/2 CS40-1 077837
3CS45-1 077838
3-1/2 CS50-1 077839
4CS55-1 077840
FITTINGS
PVC Coated Steel, 2 Hole
Size (in) Part Number Product Code
2CS35 077818
2-1/2 CS40 077819
3CS45 077820
3-1/2 CS50 077821
4CS55 077822
5CS60 077824
6CS65 077823
Pipe Straps PE, 2 Hole
Size (in) Part Number Product Code
2-1/2 PS40 077262
3PS45 077263
4PS55 077264
Pipe Straps PVC, 2 Hole
Size (in) Part Number Product Code
1/2 PS10 077811
3/4 PS15 077812
1PS20 077813
1-1/4 PS25 077814
1-1/2 PS30 077815
2PS35 077816
3938
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
FITTINGS
* Note: All access fittings are UL listed for wet locations.
Supplied with threaded brass inserts, brass screws and PVC gasketing.
Stainless steel screws are available upon request.
Access Fittings* Type LL
Size (in) Part Number Product Code
1/2 SLL10S 077521
3/4 SLL20S 077522
1SLL30S 077523
1-1/4 SLL40S 077524
1-1/2 SLL50S 077525
2SLL60S 077526
2-1/2 SLL70S 077527
3SLL80S 077528
3-1/2 SLL90S 077530
4SLL100S 077529
Access Fittings* Type C
Size (in) Part Number Product Code
1/2 SC10S 077501
3/4 SC20S 077502
1SC30S 077503
1-1/4 SC40S 077504
1-1/2 SC50S 077505
2SC60S 077506
2-1/2 SC70S 077507
3SC80S 077508
3-1/2 SC90S 077510
4SC100S 077509
FITTINGS
Access Fittings* Type LB
Size (in) Part Number Product Code
1/2 SLB10S 077541
3/4 SLB20S 077542
1SLB30S 077543
1-1/4 SLB40S 077544
1-1/2 SLB50S 077545
2SLB60S 077546
2-1/2 SLB70S 077547
3SLB80S 077488
3-1/2 SLB90S 077549
4SLB100S 077550
Access Fittings* Type LR
Size (in) Part Number Product Code
1/2 SLR10S 077481
3/4 SLR20S 077482
1SLR30S 077483
1-1/4 SLR40S 077484
1-1/2 SLR50S 077485
2SLR60S 077486
2-1/2 SLR70S 077480
3SLR80S 077488
3-1/2 SLR90S 077487
4SLR100S 077489
* Note: All access fittings are UL listed for wet locations.
Supplied with threaded brass inserts, brass screws and PVC gasketing.
Stainless steel screws are available upon request.
4140
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
FITTINGS
B
DE
B
C
J
J
* Notes: All access fittings are UL listed for wet locations.
Supplied with threaded brass inserts, brass screws and PVC gasketing.
Stainless steel screws are available upon request.
KL
I
Access Fittings* Type TB
Size (in) Part Number Product Code
1/2 STB10S 077451
3/4 STB20S 077452
1STB30S 077453
1-1/4 STB40S 077454
1-1/2 STB50S 077455
2STB60S 077456
Access Fitting Dimensions*
Size (in) A (in) B (in) C (in) D (in) E (in) F (in)
1/2 5.606 0.639 1.268 1.100 0.840 4.337
3/4 5.606 0.810 1.536 1.325 1.050 5.395
16.500 0.910 1.700 1.600 1.335 6.250
1-1/4 7.900 1.050 2.300 2.000 1.100 7.625
1-1/2 8.500 1.125 2.675 2.250 1.900 8.250
210.875 1.160 3.188 2.820 2.375 10.531
2-1/2 14.600 1.750 4.500 3.950 2.870 13.630
314.600 1.900 4.500 3.950 3.510 13.630
3-1/2 17.040 2.125 5.536 5.000 4.000 16.000
417.040 2.125 5.536 5.000 4.530 16.000
Size (in) G (in) H (in) I (in) J (in) K (in) L (in)
1/2 4.095 1.297 2.487 2.280 1.005 0.750
3/4 4.095 1.297 2.487 2.803 1.005 0.810
14.750 1.500 2.075 3.250 1.125 1.115
1-1/4 5.750 1.750 3.575 3.950 1.562 1.300
1-1/2 6.500 1.750 3.938 4.250 1.656 1.425
28.156 2.344 4.535 5.438 1.968 1.160
2-1/2 9.825 3.805 6.240 7.300 2.610 -
310.897 2.733 6.240 7.300 2.610 -
3-1/2 11.465 4.535 7.500 8.535 2.975 -
411.465 4.535 7.500 8.535 2.975 -
Not UL listed.
FITTINGS
Access Fittings* Type T
Size (in) Part Number Product Code
1/2 ST10S 077461
3/4 ST20S 077462
1ST30S 077463
1-1/4 ST40S 077464
1-1/2 ST50S 077465
2ST60S 077466
2-1/2 ST70S 077467
3ST80S 077468
3-1/2 ST90S 077471
4ST100S 077572
Access Fittings* Type E
Size (in) Part Number Product Code
1/2 SE10S 077561
3/4 SE20S 077562
1SE30S 077563
1-1/4 SE40S 077564
1-1/2 SE50S 077565
2SE60S 077566
2-1/2 SE70S 077567
3SE80S 077568
3-1/2 SE90S 077569
4SE100S 077570
* Notes: All access fittings are UL listed for wet locations.
Supplied with threaded brass inserts, brass screws and PVC gasketing.
Stainless steel screws are available upon request.
4342
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
Note: Meter risers are 2' in length and come complete with male adapter.
Slip Meter Risers
Schedule 40, Size (in) Part Number Product Code
2SMR35TA 068371
2-1/2 SMR40TA 068372
3SMR45TA 068373
4SMR55TA 068374
“Two in One” Pull Elbow
Scepter’s “two in one” access pull elbow reduces inventory
costs and increases installation flexibility (3/4" hub fitting
supplied with 3/4" x 1/2" reducers). The pull elbow is approved
for wet locations and provides for easy wire pulling. They are
manufactured from high impact, nonconducting and
noncorroding PVC.
Size (in) Part Number Product Code
1/2 or 3/4 PE15/10 077491
FITTINGS
Meter Hubs
Size (in) Part Number Product Code
1-1/4 MHU25 077961
1-1/2 MHU30 077963
2MHU35 077965
2-1/2 MHU40 077967
3MHU45 077968
FITTINGS
Service Entrance Fittings
Size (in) Part Number Product Code
1/2 EF10 077281
3/4 EF15 077282
1EF20 077283
1-1/4 EF25 077284
1-1/2 EF30 077285
2EF35 077286
2-1/2 EF40 077287
3EF45 077288
3-1/2 EF50 077289
4EF55 077290
Offset Terminal Adapters
(Meter Offsets)
Size (in) Part Number Product Code
1-1/4 MO25 077941
2MO35 077942
Long Meter Offsets
(Fabricated)
Size (in) Part Number Product Code
1-1/4 LMO25 069641
1-1/2 LMO30 069645
2LMO35 069646
4544
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
COVER PLATES
F Series - Triple Gang Plates
1.415”
dia. dia. dia.
1.610” 1.760”
DRC15/10 TSC15/10 20RC15/1020-3RC15/1030-3RC15/10 BRC15/10
GASK 15/10
F Series - Single Gang Plates
Description Part Number Product Code
Duplex Receptacle DRC15/10 077617
Toggle Switch TSC15/10 077616
Single Receptacle 20RC15/10 077618
Single Receptacle 20-3RC15/10 077619
Single Receptacle 30RC15/10 077620
Blank c/w Gasket BRC15/10 077611
PVC Gasket only for F Series Box GASK15/10 077621
Description Part Number Product Code
Blank Cover c/w Gasket BRC20-2-U 077359
Double Switch TSC20-2-U 077373
Double Duplex Receptacle DRC20-2-U 077362
Combo Switch Duplex Rec. TSDC20-2-U 077374
PVC Gasket GASK20-2 077743
Foam Gasket with Adhesive GASKFU20-2 172650
Description Part Number Product Code
Triple Receptacle DRC20-3 077747
Combo Switch Receptacle DSDR20-3 077745
Triple Switch TSC20-3 077744
Combo Switch Receptacle TSDC20-3 077746
Blank Cover c/w Gasket BRC20-3 077748
PVC Gasket GASK20-3 077749
GASK20-2
F Series - Double Gang Plates
GASKF20-2-UBRC20-2-U TSC20-2-U DRC20-2-U TSDC20-2-U
FITTINGS
Note: All grommets are supplied with TSRCU10, TSRCU15 & SRCU15.
Socket Solvent Weld Strain Relief Connectors
Size (in) Part Number Product Code
3/4 SRC15 c/w 6
grommets 077985
3/4 SRCU15 c/w 4
grommets 077209
Strain Relief Connectors Grommet Dimensions
Nonmetallic Strain Relief Connectors
Scepter’s Nonmetallic Strain Relief Connectors are supplied
with all the components you need for a complete connection.
The connector body, a selection of grommets and compression
rings accepting a range of cord dimensions, a sealing ‘O’ ring
and metallic locknut are all supplied in one package. Available
in 1/2" and 3/4" threaded hub and 3/4" PVC socket solvent
weld configurations to accommodate a variety of applications.
Threaded, Strain Relief Connector
c/w “O”Ring, Locknut & 4 Grommets
Threaded, Strain Relief Connector
c/w “O”Ring, Locknut & 6 Grommets
Size (in) Part Number Product Code
1/2 TSRCU10 077244
3/4 TSRCU15 077261
Size (in) Part Number Product Code
1/2 TSRC10 077754
3/4 TSRC15 077756
GASK20-3
W = .195 W = .285
L = .450 L = .530
W = .220 W = .291
L = .516 L = .565
Ø = .240 Ø = .300"
Ø = .290 Ø = .385
Ø = .405 Ø = .500
Ø = .525 Ø = .625
4746
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
WEATHERPROOF COVERS
VSC20-2-U
VSRC20-2-U
VSDR20-2-U
Weatherproof Covers - Double Gang
Note: Weatherproof covers, with lids closed, are UL Listed for wet
locations.
Description Part
Number Product
Code
Toggle Switch Cover VSCU20-2 077376
Combination Switch
& GFI Receptacle VSRC20-2 077357
Combination Switch
& Duplex Receptacle VSDRU20-2 077356
Double Door GFI
Cover VSGG20-2 077096
Double Door Duplex
Cover VSDD20-2 077097
Gasket for 2-Gang ‘F’
Boxes (except
VSGG20-2 & VSDD20-2) GASKFU20-2 172650
Gasket for VSGG20-2
& VSDD20-2 Double
Gangs GASKV20-2 072227
VSDD20-2
VSGG20-2
WEATHERPROOF COVERS
WTL15
WTL20
WTL30
WDR15/10
RWDR15/10
WTL50
WGF15/10
RWGF15/10
WDRE15/10
RWDRE15/10
Description (in) Part
Number Product
Code
Plunger-style Switch
Cover VPT15/10 077630
Toggle Switch Cover VSC15/10 077612
Grey Toggle Switch
Cover WTG15/10 077606
Grey Duplex
Receptacle WDR15/10 077993
White Duplex
Receptacle RWDR15/10 077786
Grey Ground Fault
Receptacle WGF15/10 077785
White Ground Fault
Receptacle RWGF15/10 077787
Single Receptacle
Device 15 AMP 1.375 WTL15 077992
Single Receptacle
Device 20 AMP 1.625 WTL20 077994
Single Receptacle
Device 30 AMP 1.722 WTL30 077991
Single Receptacle
Device 50 AMP 2.187 WTL50 077951
Grey Double Door
Duplex Receptacle WDRE15/10 077087
White Double Door
Duplex Receptacle RWDRE15/10 077408
Gasket for W Series
Cover (except WDRE
& RWDRE) GASKW 077755
Gasket for WDRE &
RWDRE Covers GASKDD 072225
Weatherproof Covers - Single Gang
VSC15/10
VPT15/10
WTG15/10
Note: Weatherproof covers, with lids closed, are UL
Listed for wet locations.
4948
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
BOXES
FD-3
FSC-3-101520
FS-3-101520
H
W
D
F Series Double Gang Boxes
FS-2-U cu.in. = 38.5, FSC-2-U & FSS-2-U cu.in. = 37.0,
FSCC-2-U cu.in.= 35.0, FD-2-U cu.in.= 47.5
Hub Size
(in) Part Number Product
Code OD (inches)
H W D
1/2, 3/4, 1 FS-2-101520-U 077364 4.62 4.62 2.5
1/2, 3/4, 1 FSC-2-101520-U 077368 4.62 4.62 2.5
1/2, 3/4, 1 FSS-2-101520-U 077372 4.62 4.62 2.5
1/2, 3/4, 1 FSCC-2-101520-U 077369 4.62 4.62 2.5
Blank FD-2-U 077649 4.62 4.62 3.0
F Series Triple Gang Boxes
FS-3 cu.in. = 56.0, FSC-3 cu.in. = 54.0
Hub Size (in) Part Number Product
Code OD (inches)
H W D
1/2, 3/4, 1 FS-3-101520 077337 4.5 6.6 2.5
1/2, 3/4, 1 FSC-3-101520 077438 4.5 6.6 2.5
Blank FD-3 077737 4.5 6.6 3.0
Note: All F series & octagonal boxes are supplied with integral
mounting feet, threaded brass inserts and grounding clips
FD-2-U
FSS-2-101520-U
FSCC-2-101520-U
FS-2-101520-U
FSC-2-101520-U
BOXES
F Series Single Gang Boxes
Outside Dimensions:
Height, 49/16" – Width, 213/16" – Depth 2", Cubic Inches = 25.67
Size (in) Part Number Product Code
1/2 FSC10 077607
3/4 FSC15 077608
1/2 FS10 077601
3/4 FS15 077602
1/2 FSCC10 077622
3/4 FSCC15 077623
1/2 FSS10 077604
3/4 FSS15 077605
Note: 10 = 1/2" Hub, 15 = 3/4" Hub
FS FSCC
FSC FSS
FD Series Single Gang Deep Boxes
Outside Dimensions:
Height, 49/16" – Width, 213/16" – Depth 23/4", Cubic Inches = 35.30
With the exception of the FD Blank Box, Scepter FD Series
Single Gang Deep Boxes are molded with 1" conduit hubs and
supplied with reducer bushings. The conduit hub(s) are field
modified as 1/2", 3/4" or 1" to accommodate job-site
requirements. The appropriate quantity of 1" x 3/4" and 3/4" x
1/2" reducers to create the desired hub size are packaged with
each FD Series Single Gang Deep Box.
Size (in) Part Number Product Code
1/2, 3/4, 1 FDC101520 077291
1/2, 3/4, 1 FDS101520 077299
BLANK FD BLANK 077603
347 VOLT FD347 077610
FDC101520
FDS101520
FD Blank
Note: 10 = 1/2" Hub, 15 = 3/4" Hub, 20 = 1" Hub
5150
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
Fabricated Boxes
Unflanged PVC fabricated boxes of any size may be made to
customers’ specifications and come complete with lids,
gaskets and screws. These boxes are not UL Listed and are not
returnable.
BOXES
BCAA
F
B
CD
E
Junction boxes are supplied
with threaded brass
inserts, brass screws,
PVC gasketing and
mounting feet. Nylon
and stainless steel
screws, and larger sizes
of fabricated junction
boxes, are available
upon request.
Part
Number Product
Code A
(in) B
(in) C
(in) E
(in) E
(in) F
(in)
JB442 077659 3.675 4.000 3.450 2.125 2.000 8-32
JB444 077696 3.675 4.000 3.450 4.188 3.750 8-32
JB446 077669 3.675 4.000 3.450 6.225 6.000 8-32
JB552 077670 4.680 5.000 4.485 2.000 1.845 8-32
JB664 077697 6.000 6.375 5.813 4.180 4.000 10-32
JB666 077698 6.000 6.375 5.813 6.188 6.000 10-32
JB884 077664 8.075 8.625 7.966 4.230 4.005 1/4-20
JB887 077671 8.100 8.625 7.966 7.250 7.035 1/4-20
JB12124 077672 12.085 12.580 11.874 4.256 4.030 1/4-20
JB12126 077666 12.085 12.580 11.874 6.240 6.025 1/4-20
JB12128 077668 12.085 12.580 11.874 8.250 8.025 1/4-20
PVC Molded Junction Boxes
(F = Threaded brass insert size.)
Scepter PVC junction boxes are:
NEMA 1, 2, 3, 4, 4X, 6P, 12, 13
UL listed for wet locations
LFB150C
Threaded Round Box
Scepter’s Threaded Junction Boxes are corrosion resistant,
non-conductive and incorporate high-temperature silicone
gaskets and brass hardware to withstand extreme temperature
variations. Manufactured from glass-reinforced thermoplastic
polyester resin, these boxes can endure extreme temperatures
(material temperature range -40°F to +302°F).
BOXES
Octagonal Boxes*
Octagonal Boxes are shipped complete with
cover, gasket, 4 reducing bushings (3/4" x
1/2") and 4 sealing caps to be installed from
inside box to seal off unused entry hubs.
Size (in) Part Number Hub Size (in) Product Code
4 x 1-1/2 OB15/10 1/2 – 3/4 077983*
4 x 2-1/8 OB20 1077984*
Octagonal Box Extension Rings*
Size (in) Part Number Product Code
4 x 1 deep XR20 077989*
4 x 2 deep XR35 077990*
* Octagonal Boxes are not designed for supporting luminaries.
Note: All F series & octagonal boxes are supplied with integral
mounting feet, threaded brass inserts and grounding clips
Size (in) Part Number Product Code
4 - 3/4" Threaded Hubs LFB150C 077250
4 - 3/4" Threaded Hubs
c/w 1/2" Threaded Hole in Cover LFB150T 077251
LFB150T
5352
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
BOXES
Floor Box Base
(Includes disposable protective cap & reducer plugs)
076954 FB
Floor Box Base c/w Leveling Ring Adapter
(includes disposable protective cap, reducer plugs
& leveling ring adapter)
077068 FBKIT
Floor Box Stand Kit (includes FB Box)
(is equiped with several height brackets which
accommodate the different rebar and post-tension cable heights and
slab depths found from job-site to job-site.)
077700 FBSKIT
Metal Cover Adapter Kit
(includes leveling ring, metal cover adapter & 2 gaskets)
076953 AFMC
Universal Leveling Ring Adapter
076606 LRA-U
Floor Box Duplex Receptacle Cover (Nonmetallic)
(includes flush mount cover, blank cover & gasket)
Brown 076955 FBDRCB
Gold 076949 FBDRCG
Grey 076600 FBDRCGr
Light Almond 076605 FBDRCA
Nonmetallic Floor Box, Cover & Metal Cover
Adapter
Installation is quick and simple with our nonmetallic floor box
and covers, saving both time and money over similar metallic
assemblies.
Scepter’s floor box and duplex receptacle covers are constructed
from high impact, noncorroding and nonconducting PVC.
The flush-mount covers are available in custom colors and are
shipped with a leveling ring. Metal cover adapter kits are also
available, allowing you to adapt to metal floor plates. Our 6" deep
floor box allows flexibility for various concrete floor pours, while the
4-3/4" width offers easy access and ample wire room. Scepter’s FB
box is molded with 2 - 1" and 2 - 3/4" hub openings.
All boxes are shipped complete with reducer plugs for added
versatility.
FB
AFMC
LRA-U
FBDRC
Description Product
Code Part
Number
BOXES
Standard PVC
Coupling
Flanged Box with Fiber-Reinforced Safety
Tread Cover
Scepter’s Flanged ‘H’ Series Junction Boxes provide H10 Highway
Loading. The fiber-reinforced safety tread cover secures using
recessed Hex Key fastening hardware offering a simple installation
while reducing the opportunity for tampering.
C
B
A
C
H887 H887-A
Junction Box Adapters
Junction Box Adapters, installed using
a standard PVC coupling, offer a
trouble-free and reliable PVC
connection. In addition to providing a
strong connection, the JBA also
maximizes the interior box wiring
space unlike the use of male adapters
(TA) and facilitates wire pulling - the
smooth internal edges limiting the
potential for wire damage.
Size (in) Part Number Product Code
1/2 JBA10 077721
3/4 JBA15 077722
1JBA20 077723
1-1/4 JBA25 077724
1-1/2 JBA30 077725
2JBA35 077726
2-1/2 JBA40 077727
3JBA45 077728
3-1/2 JBA50 077729
4JBA55 077730
Junction Box
Adapter
Part
Number Product
Code Box ID (in)
L W D Lid Dimensions (in)
A B C
H664 077685 6 6 4-1/4 9.0 9.0 0.60
H666 077686 6 6 6-1/4 9.0 9.0 0.60
H884 077687 8 8 4-1/4 11.5 11.5 0.75
H886 077688 8 8 6-1/4 11.5 11.5 0.75
H887 077689 8 8 7-1/4 11.5 11.5 0.75
H887-A 077692 8 8 7-1/4 11.5 11.5 0.75
FBS-KIT
Junction box and couplings
sold separately
5554
SCEPTER CONDUIT
FITTINGS
SCEPTER CONDUIT
FITTINGS
SPACERS
COVER PLATES / CEMENTS & PRIMER
Brass Cover Plates
(offers a one-piece design measuring 5-3/4"
diameter. Are available in a variety of
styles accommodating power and
communication needs. Install to the FB
box using the universal leveling ring adapter.
Cements
Size Part Number Product Code
250ml (1/2 Pint) S100PT5 078883
500ml (Pint) S100PT 078884
1L (Quart) S100QT 078885
4L (Gallon) S100GAL 078887
Primer
c/w Applicator Cap
Size Part Number Product Code
250ml (1/2 Pint) C100PT5 078163
500ml (Pint) C100PT 078174
1L (Quart) C100QT 078175
Size Part Number Product Code
500ml (Pint) CWC10 078503
1L (Quart) CWC20 078886
Scepter 100 - Cold Weather / Wet Weather
Cement
Description Part Number Product Code
Duplex Screw Cover DSC 178091
Duplex Screw Cover DSC-P/C 178092
Single Screw Cover SSC 178093
Single Screw Cover SSC-P/C 178094
Duplex Flip Lid (single) DFL-1 178095
Duplex Flip Lid (double) DFL-2 178096
Tri-Service Universal Divider Kit
(includes upper & lower dividers, riser tube & two grommets)
077948 FBUDK
Y Connector (3/4")
077499 FBYC
FBUDK
FBYC
Intermediate
Vertical-Lok Spacers
Dimension
(in) Part Number Product
Code A inches B inches C inches
2 x 1-1/2 IS3530 029550 1.500 3.937 0.62
2 x 2 IS3535 029551 2.000 4.488 0.62
2 x 3 IS3545 029552 3.000 5.433 0.62
3 x 1-1/2 IS4530 029553 1.500 5.130 no rebar slots
3 x 2 IS4535 029554 2.000 5.630 0.87
3 x 3 IS4545 029555 -6.614 0.87
4 x 1 IS5520 029556 1.000 5.630 no rebar slots
4 x 1-1/2 IS5530 029557 -6.614 0.87
4 x 2 IS5535 029558 2.000 6.614 0.87
4 x 3 IS5545 029559 3.000 7.638 0.87
5 x 1-1/2 IS6030 029560 1.500 7.325 no rebar slots
5 x 2 IS6035 029561 2.188 7.874 0.87
5 x 3 IS6045 029562 3.188 8.701 0.87
6 x 1-1/2 IS6530 029563 -7.441 0.87
6 x 2 IS6535 029564 -7.677 0.87
6 x 3 IS6545 029565 3.000 9.764 0.87
8 x 2 IS8035 029294 - - no rebar slots
BB
A
B
BBB
B1
B
C
A
A1
C
CONDUIT REPAIR KIT 57
CONDUIT REPAIR KIT
56
SCEPTER CONDUIT
FITTINGS
SPACERS / CONDUIT REPAIR KIT
Size (in) Part Number Product Code Length (in)
1-1/4 EPR25 077976 24
1-1/2 EPR30 077971 24
2EPR35 077972 24
2-1/2 EPR40 077973 24
3EPR45 077974 24
4EPR55 077975 24
5EPR60 077977 24
6EPR65 077979 24
EPR Kits for Conduit Repair
EPR Kits from IPEX are the first total
repair systems for broken and damaged
PVC conduit. They offer fast and easy
repairs for damaged conduit caused by
actions such as earth excavation,
horizontal and core drilling.
All sizes are 24 inches in length.
Base
Vertical-Lok Spacers
Dimension
(in) Part Number Product
Code A inches B inches C inches
2 x 1-1/2 BS3530 029566 2.992 3.937 0.62
2 x 2 BS3535 029567 2.992 4.488 0.62
2 x 3 BS3545 029568 2.992 5.433 0.62
3 x 1-1/2 BS4530 029569 3.000 4.615 no rebar slots
3 x 2 BS4535 029570 2.992 5.630 0.87
3 x 3 BS4545 029571 2.992 6.614 0.87
4 x 1 BS5520 029572 1.750 4.060 no rebar slots
4 x 1-1/2 BS5530 029573 2.992 6.614 0.87
4 x 2 BS5535 029574 2.992 6.614 0.87
4 x 3 BS5545 029575 2.992 7.638 0.87
5 x 1-1/2 BS6030 029576 3.000 6.900 no rebar slots
5 x 2 BS6035 029577 2.992 7.874 0.87
5 x 3 BS6045 029578 2.992 8.701 0.87
6 x 1-1/2 BS6530 029579 3.031 7.441 0.87
6 x 2 BS6535 029580 3.031 7.677 0.87
6 x 3 BS6545 029581 2.992 9.764 0.87
8 x 2 BS8035 029293 - - no rebar slots
59
SCEPTALIGHTTM
SCEPTALIGHT: The Light That Lasts
Sceptalight fixtures from IPEX prove themselves to be all-round
performers in a variety of indoor and outdoor applications.
Sceptalight fixtures are made from a glass-reinforced
thermoplastic polyester resin, which enable them to stand up
better to corrosive elements than metal. This thermoplastic
design marries an unrivaled balance of strength, stiffness and
toughness with all the benefits users appreciate of Scepter
rigid PVC conduit and fittings - long life, easy servicing and
high impact-resistance.
Sceptalight's thermoplastic construction offers outstanding
corrosion and chemical resistance. And its interior and exterior
silicone gaskets create a watertight seal, the reason it performs
equally well indoors and outside.
Features and Benefits
• Stable Construction
• Watertight seal with weather-resistant silicone gaskets
• Corrosion Resistant
• Durable and Impact Resistant
Mounting Options
Box with four 3/4
"
threaded hubs and
integral mounting feet.
CEILING MOUNT
Box with four 3/4
"
threaded hubs, 90º wall
bracket and integral
mounting feet.
WALL MOUNT
Pendant cap with
3/4
"
threaded hub
and a locking set
screw.
PENDANT MOUNT
SCEPTALIGHT
NOTES
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
6160
SCEPTALIGHT
SCEPTALIGHT
SCEPTALIGHTTM
Wet Locations
Ceiling Mount
Ceiling Mount
with Standard Clear Glass Globe Part
Number Product
Code
150W Incandescent LVPF150C 077225
150W Incandescent less guard LVPF150LG 077237
26W Compact Fluorescent LVPL26C 077170
18W Compact Fluorescent LVPL18C 077210
13W Compact Fluorescent LVPL13C 077122
9W Compact Fluorescent LVPL9C 077121
7W Compact Fluorescent LVPL7C 077120
Ceiling Mount with Clear Polycarbonate
Glass Globe (no guard) Part
Number Product
Code
26W Compact Fluorescent LVPL26PCC 077176
18W Compact Fluorescent LVPL18PCC 077211
13W Compact Fluorescent LVPL13PCC 077165
9W Compact Fluorescent LVPL9PCC 077155
7W Compact Fluorescent LVPL7PCC 077145
4 3/4"
10"
6"
9 1/2"
4 3/4"
11 3/4"
Ceiling Mount Ceiling Mount Ceiling Mount
Polycarbonate Globe
C22.2 No. 250
UL 1598
Minimum 60ºC supply conductors
Wall Mount Bracket
Description Part
Number Product
Code
Use with Wet, Marine and Hazardous
locations. For wall mount fixtures select
and order the appropriate style (wattage
and globe) ceiling mount fixture from
above and add LWB150.
LWB150 077233
SCEPTALIGHTTM
Globe Options
Sceptalight offers a variety of globe options to suit a wide range
of applications and environments. Our standard clear glass
globes are ideal for general purpose area lighting for either
indoor or outdoor use. Polycarbonate globes offer impact
resistance in case of accidental contact and the assurance that
work areas are not contaminated by broken glass. Colored
globes - available in red, blue, green or amber - can transform
the light to an indicator or warning light.
Light Options
Fluorescents
Our compact fluorescent fixtures work four to five times more
efficiently per watt than incandescents and provide 10-20
times the lamp life, yet use approximately 75% less energy. In
this way, Sceptalight fluorescents lower energy and maintenance
costs without sacrificing light levels.
Incandescents
With their low initial cost, Sceptalight incandescent fixtures
make the most practical choice to meet the daily needs of
commercial, industrial, marine and agricultural applications.
Our incandescents are ideal for short burn times as well as
flashing and dimming applications.
Heat-treated
Amber Glass
Heat-treated
Green Glass
Heat-treated
Blue Glass
Heat-treated
Red Glass
Clear
Polycarbonate Standard or Heat-treated
Clear Glass
Wet
Locations con’t
Pendant Mount
6362
SCEPTALIGHT
SCEPTALIGHT
SCEPTALIGHTTM
Ceiling Mount
with Heat Resistant Glass Globe Part
Number Product
Code
150WIncandescent clear LVPF150HRC-HAZ 077414
150WIncandescent red LVPF150HRR-HAZ 077415
150WIncandescent blue LVPF150HRB-HAZ 077416
150WIncandescent green LVPF150HRG-HAZ 077417
150WIncandescent amber LVPF150HRA-HAZ 077494
26WCompact Fluorescent clear LVPL26HRC-HAZ 077377
26WCompact Fluorescent red LVPL26HRR-HAZ 077378
26WCompact Fluorescent blue LVPL26HRB-HAZ 077379
26WCompact Fluorescent green LVPL26HRG-HAZ 077399
26WCompact Fluorescent amber LVPL26HRA-HAZ 077400
18WCompact Fluorescent clear LVPL18HRC-HAZ 077347
18WCompact Fluorescent red LVPL18HRR-HAZ 077348
18WCompact Fluorescent blue LVPL18HRB-HAZ 077349
18WCompact Fluorescent green LVPL18HRG-HAZ 077353
18WCompact Fluorescent amber LVPL18HRA-HAZ 077354
Hazardous
Locations
Ceiling Mount
Pendant Mount
with Heat Resistant Glass Globe Part
Number Product
Code
150WIncandescent clear LPMF150HRC-HAZ 077495
150WIncandescent red LPMF150HRR-HAZ 077496
26WCompact Fluorescent clear LPPL26HRC-HAZ 077407
26WCompact Fluorescent red LPPL26HRR-HAZ 077409
18WCompact Fluorescent clear LPPL18HRC-HAZ 077500
18WCompact Fluorescent red LPPL18HRR-HAZ 077498
Pendant Mount
UL 844
Class I, DIV 2 Groups A,B,C & D
Class II, DIV 2 Groups F & G
Minimum 90oC supply conductors
Wall Mount Bracket
Description Part
Number Product
Code
Use with Wet, Marine and Hazardous
locations. For wall mount fixtures select
and order the appropriate style (wattage
and globe) ceiling mount fixture from
above and add LWB150.
LWB150 077233
SCEPTALIGHTTM
Pendant Mount
with Standard Clear Glass Globe Part
Number Product
Code
150W Incandescent LPMF150C 077231
26W Compact Fluorescent LPPL26C 077184
18W Compact Fluorescent LPPL18C 077212
13W Compact Fluorescent LPPL13C 077185
9W Compact Fluorescent LPPL9C 077183
7W Compact Fluorescent LPPL7C 077182
Pendant Mount with Clear
Polycarbonate Globe (no guard) Part
Number Product
Code
26W Compact Fluorescent LPPL26PCC 077375
18W Compact Fluorescent LPPL18PCC 077273
13W Compact Fluorescent LPPL13PCC 077365
9W Compact Fluorescent LPPL9PCC 077355
7W Compact Fluorescent LPPL7PCC 077345
4 3/4"
10 1/4"
4 3/4"
12"
Marine
Locations
Ceiling Mount
Pendant
Ceiling Mount
with Heat Resistant Glass Globe Part
Number Product
Code
100W Incandescent LVPF100C-MAR 077275
Ceiling Mount
with Heat Resistant Glass Globe Part
Number Product
Code
100W Incandescent LPMF100C-MAR 077276
C22.2 No. 250
UL 1598, UL 1598A, UL 1598
Minimum 110oC supply conductors
SCEPTALIGHTTM 6564
SCEPTALIGHT
SCEPTALIGHT
SCEPTALIGHTTM
Nonmetallic Utility Light Fixture
Globe Description Part
Number Hub
Size (in) Product
Code
Fixture c/w
Clear Glass Globe LVPE150-10/15 1/2 x 3/4 077493
Fixture c/w Clear
Polycarbonate Globe LVPE150-PCC* 1/2 x 3/4 077181
Fixture c/w Heat
Resistant Clear Globe LVPE150-HRC 1/2 x 3/4 077578
Fixture c/w Heat
Resistant Red Globe LVPE150-HRR 1/2 x 3/4 077599
Fixture c/w Heat
Resistant Blue Globe LVPE150-HRB 1/2 x 3/4 077579
Fixture c/w Heat
Resistant Green Globe LVPE150-HRG 1/2 x 3/4 077597
Fixture c/w Heat
Resistant Amber Globe LVPE150-HRA 1/2 x 3/4 077598
Replacement
Clear Glass Globe LGC150 077247
Nonmetallic
Clamp-on Guard LVPUG150 077558
Fixture c/w
Clear Glass Globe &
Clamp-on guard LVPE150-1015G 1/2 x 3/4 077402
* Maximum 60W incandescent lamp with polycarbonate globe
LVPE150 LVPE150-PCC
5 1/8"
11"
5 1/8"
9 7/8"
3 1/2"
*
LVPUG150 LVPE150-1015G
Accessories & Components
Heat Resistant Globes
Description Part Number Product Code
Clear LG150T 077909
Red LCGR150T 077239
Blue LCGB150T 077910
Green LCGG150T 077241
Amber LCGA150T 077242
Polycarbonate Globes (for use with
compact fluorescent or maximum 60W incandescent lamp)
Description Part Number Product Code
Clear LPCC18 077911
Red LPCR18 077912
Blue LPCB18 077913
Green LPCG18 077914
Amber LPCA18 077915
Standard Glass Globes
Description Part Number Product Code
Clear LGC150 077247
KWIKFLEX®67
KWIKFLEX
KWIKFLEX: NMLT Conduit & Fittings
Kwikflex®NMLT Type B on reels are UL listed in all lengths
Available in sizes from 3/8" to 2", reels offer the end user the
best possible continuous length in the market place. Its
patented design offers a low profile coupling that when two
conduits are connected it is hardly noticeable and allows the
user to run the conduit at any length desirable. There is no
longer any need for additional parts when making a long
conduit run.
Kwikflex NMLT is also available in extra-flexible formulations in
sizes 3/8" to 2"
Coils come packaged in easy to ship cartons
Coils are conveniently packaged in cardboard boxes to keep the
pipe clean and come with a center knock-out for easy dispensing.
Applications
• HVAC equipment
• Machine tools
• Marine equipment
• Motors & controls
• Printing equipment
• Pumps
• Refrigeration equipment
• Transformer connections
• Outdoor lighting
NOTES
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
6968
KWIKFLEX
KWIKFLEX
KWIKFLEX®
KWIKFLEX®
NMLT Flexible Conduit
(Grey) Type B
Size (in) Product Code Length (ft)
3/8 165005 100
1/2 165007 100
3/4 165009 100
1165011 100
1-1/4 165014 100
1-1/2 165017 50
1-1/2 165021 100
2165020 50
NMLT Flexible Conduit Reels
(Grey) Type B
Size (in) Product Code Length (ft)
1/2 165082 1000
3/4 165085 700
1165090 500
NMLT 90º Elbows (Grey)
Size (in) Part Number Product code
3/8 LTB03/90 065306
1/2 LTB10/90 065307
3/4 LTB15/90 065310
1LTB20/90 065312
1-1/4 LTB25/90 065314
1-1/2 LTB30/90 065317
2 LTB35/90 065320
NMLT Extra Flexible Tubing
(Black)
Size (in) Product Code Length (ft)
3/8 165055 100
1/2 165057 100
3/4 165059 100
1165061 100
1-1/4 165064 100
1-1/2 165067 100
2 165070 100
Other packages sizes available on request
NMLT Screw-on 90º Elbows
(Grey)
Size (in) Part Number Product code
1/2 LTD10/90 065350
3/4 LTD15/90 065352
NMLT Straight Fittings (Grey)
Size (in) Part Number Product code
3/8 LTS03 065326
1/2 LTS10 065327
3/4 LTS15 065330
1LTS20 065332
1-1/4 LTS25 065334
1-1/2 LTS30 065337
2 LTS35 065340
71
KWIKON®ENT
Kwikon®ENT
Savings for the Long Run
Noncorroding and nonconducting, Kwikon Electrical Nonmetallic
Tubing and fittings are designed
For The Long Run
. Coiled in
lengths up to 1,500 feet, the Kwikon system can span the
longest run. Encased in concrete, concealed in walls or ceilings,
Kwikon offers the best alternative to the labor-intensive, 10'
lengths of metal conduit with its couplings and scrap.
Now you can use the Kwikon ENT system for communications
(yellow), fire alarm and emergency (red), as well as power
(blue) applications. It comes with color-coded stripes for easy
identification on 1,500 ft., 1000 ft. and 750 ft. reels. The
Kwikon ENT system is the right choice.
Kwikon Fittings
Our unique Kwikon couplings, transition couplings and
connectors are designed with six 360° locking tabs to ensure a
secure concrete-tight connection.
Time-consuming taping and solvent welding are eliminated.
Kwikon fittings are permitted for use with all UL Listed and
CSA certified ENT.
UL 514B, UL 514C
UL 1653 TC-13 C22.2 No. 21127, C22.2 No. 85
FT-4 Rated
70
KWIKON ENT
KWIKFLEX
KWIKFLEX®
NMLT Screw-on Straight Fittings
(Grey)
Size (in) Part Number Product code
1/2 LTD10 065360
3/4 LTD15 065362
NMLT Screw-on Multi Angle
Fittings (Grey)
Size (in) Part Number Product code
1/2 LTMA10 065015
3/4 LTMA15 065016
7372
KWIKON ENT
KWIKON ENT
ENT TUBING
Exposed Work
ENT is permitted to be used for exposed work, where not subject
to physical damage, in buildings not exceeding 3 floors above grade.
Pulling Wire
Kwikon’s interior corrugated surface
greatly reduces the amount of friction
while pulling conductors through long
runs, even with 90° bends.
Transition from ENT to EMT
Transition from ENT to EMT no longer
requires solvent welding. Simply connect
the Kwikon transition coupling to EMT
with the set screw and snap on to ENT.
NEC, Article 362
Rules governing the installation of
Kwikon ENT are covered in the 2011
National Electrical Code, ANSI/NFPA
Article 362. Kwikon ENT systems are
recognized for use in places of assembly
as referenced in Articles 518 & 520.
Kwikon ENT may be installed exposed, in
areas not subject to physical damage
where the building does not exceed three
floors above grade [(362.10 (1)].
Kwikon ENT may be concealed in floors, walls, ceilings and
suspended ceilings where a thermal barrier of material has a
minimum of 15-minute finish rating.
NOTE: Kwikon ENT may
penetrate fire-rated walls, floors or ceilings with a UL Listed or
recognized through-penetration fire-stop system.
Fire Resistive Construction & Wall Assemblies
Kwikon ENT tubing, Kwikon fittings and
Kwikon slab boxes are approved for use in
noncombustible 2 hr. and 4 hr. fire rated
floor-ceiling assemblies. Normal weight
concrete cover must be provided of a
minimum of 2-1/8" for 2 hr. assemblies
and 2-3/8" for 4 hr. assemblies. [ULI File:
E 78276 and ULC File: R-19226].
Kwikon ENT and Kwikon fittings have
been investigated for use in a nonload-
bearing wall and partition assembly. The
report (ULC CR2196) concludes the wall
assemblies with Kwikon ENT and fittings
will provide a 2 hr. resistance to the
passage of flame and dangerous
transmission of heat.
Ease of Installation
Engineered for the rugged day-to-day
challenges of the construction industry,
Kwikon has already established itself as
a market leader. Requiring no special
tools for bending or cutting, Kwikon is
easily installed.
Bending & Cutting
Kwikon’s corrugated construction allows
it to be easily bent by hand, no longer
requiring special bending equipment
traditionally required with metal conduit
systems. When bending, ensure the
radius of the curve is at least six times
the internal diameter of the tubing.
Kwikon Slab Boxes
Kwikon slab boxes are available with or
without molded connectors. For boxes
without molded connectors, preassembly
is quick and simple using our threaded
male adapter with locknuts. This provides
a secure concrete-tight connection.
Pre-Assembly of Metallic
Boxes
Metal slab boxes can be quickly
preassembled with Kwikon connectors.
Secured with a locknut, Kwikon connectors
provide a concrete-tight connection.
Installation in Sheer Walls,
Interior Walls & Block Walls
Kwikon’s flexibility, lightweight and ease of
handling in metal, wood or block walls,
combined with Kwikon connectors and
couplings, substantially reduce time and
labor needed to install electrical raceways.
Use in Ceilings
Kwikon ENT is permitted for use in
ceilings where not subject to physical
damage and in buildings 3 storeys or more
provided the ceiling provides a 15-minute
finish rating.
ENT TUBING
7574
KWIKON ENT
KWIKON ENT
E 59258, E 119384 TC-13 C22.2 No. 227.1
KWIKON®COUPLINGS / CONNECTORS
Kwikon Coupling
Size (in) Part Number Product Code
1/2 KC10 089000
3/4 KC15 089001
1 KC20 089002
1-1/4 KC25 189670
1-1/2 KC30 189671
2KC35 189672
Kwikon Connector For
Concrete Encasement
Size (in) Part Number Product Code
1/2 KTA10 089006
3/4 KTA15 089007
1 KTA20 089008
1-1/4 KTA25 189680
1-1/2 KTA30 189681
2KTA35 189682
Kwikon Snap-in Connector
Size (in) Part Number Product Code
1/2 KTS10 089146
3/4 KTS15 089147
1 KTS20 089148
Kwikon Transition Coupling
Size (in) Part Number Product Code
1/2 KTC10 089012
3/4 KTC15 089013
1 KTC20 089014
ENT TUBING
Kwikon ENT - Blue Stripe
Wrapped in plastic, coils are easily dispensed from the center.
ReelCoil
All Kwikon ENT is UL Listed for use in walls, floor slabs and
ceilings, as outlined in Article 362 of the 2005 NEC Code.
Storage of Kwikon ENT Tubing
Manufacturer recommends that ENT tubing should not be
stored outdoors where subjected to direct sunlight without
protective covering, i.e. packaging or tarps.
Size (in) Length (ft) Product Code Weight lbs/pkg
1/2 1500 012002 165
3/4 1000 012011 158
1 750 012021 160
1-1/4 1000 012047 193
1-1/2 750 012033 205
2 500 012044 220
1/2 200 012031 20
3/4 100 012040 12.5
1 100 012041 17
1-1/4 500 012046 76
1-1/2 300 012032 50.5
2 225 012043 69.5
Kwikon ENT - 10' Sticks with Blue Stripe
Size (in) Length (ft) Product Code Crate Qty
1/2 10 012001 3,600
3/4 10 012010 2,200
110 012034 1,800
Kwikon ENT Reels - Color Coded
Size
(in) Length
(ft) Product Code Weight
lbs/reel
Red Yellow Blue
1/2 1500 012305 012335 012002 165
3/4 1000 012307 012337 012011 158
1750 012310 012340 012021 160
1-1/4 1000 012037 012038 012047 193
1-1/2 750 012035 012036 012033 205
2500 012039 012042 012044 220
E 122659 TC-13
7776
KWIKON ENT
KWIKON ENT
KWIKON®ESU & ACCESSORIES
Kwikon 90oStub Down Fittings
Size (in) Part Number Product Code
1/2 KT90-10 089060
3/4 KT90-15 089059
1 KT90-20 089058
KT90 Stub Down Fittings
(Kwikon x Threaded)
Size (in) Part Number Product Code
1/2 KK90-10 089055
3/4 KK90-15 089056
1 KK90-20 089057
KK90 Stub Down Fittings
(Kwikon x Kwikon)
Kwikon ENT Form Stubby
Size (in) Part Number Product Code
1/2 KSTB-10 089330
3/4 KSTB-15 089331
1 KSTB-20 089332
1-1/4 KSTB-25 089333
Kwikon ENT Multi-LinkTM
Form Stubby
Size (in) Part Number Product Code
1/2 MSTB-10 089031
3/4 MSTB-15 089026
1 MSTB-20 089025
Kwikon ENT Angled Form Stubby
Size (in) Part Number Product Code
1/2 KASTB-10 089233
3/4 KASTB-15 089234
1KASTB-20 089235
1-1/4 KASTB-25 089236
1-1/2 KASTB-30 089238
KWIKON®COUPLINGS / CONNECTORS
Accessories
The
NEW ENT Support Unit (ESU)
raises the tubing or conduit up off the concrete form
during the concrete pour maintaining a level
raceway and allows for maximum aggregate flow and
concrete consolidation.
Easy to use, the ESU snaps around any size of ENT.
It is perfect for use in high rise buildings constructed with post-
tensioned (PT) concrete slabs.
Features
• One size fits all 1/2" - 2"
• Saves time and labour
• Easy locking mechanism
• Securable to the concrete form
• Minimal footprint reduces amount of surface contact
Part Number Product Code
ESU-10-35 089149
Tapered Plugs
Size (in) Part Number Product Code
1/2 TP10 089003
3/4 TP15 089004
1TP20 089005
Kwikon Cutter & Blades
Description Part Number Product Code
Cutter (1/2"- 1") CLC20 089066
Blades for CLC20 SSB 089067
Cutter (1/2"- 2") CLC35 089068
Blades for CLC35 SB35 089069
7978
KWIKON ENT
KWIKON ENT
KWIKON®SLAB BOXES
Hub Size (in) Part Number Product Code
8 x 1/2 SMBS-H-10 089480
4 x 1/2 & 4 x 3/4 SMBS-H-10/15 089481
8 x 3/4" SMBS-H-15 089482
4 x 1/2, 2 x 3/4, 2 x 1 SMBS-H-10/20 089483
4 x 3/4 & 4 x 1 SMBS-H-15/20 089484
Hub Size (in) Part Number Product Code
8 x 1/2 SMBS-10 089490
4 x 1/2, 2 x 3/4, 2 x 1 SMBS-10/20 089491
Description Part Number Product Code
4 x 1/2", 2 x 3/4", 2 x 1" MB-10/20 089016
8 x 1/2" knockouts MB-10 089017
Shallow Slab Box
ENT Slab Box
Slab Box with Knockouts (w/o Molded Connectors)
Shallow Slab Box with Molded Connectors
Shallow Slab Box without Molded Connectors
Description Part Number Product Code
8 x 1/2" connectors MBH-10 089022
8 x 3/4" connectors MBH-15 089018
4 x 1/2", 4 x 3/4" connectors MBH-10/15 089020
4 x 1/2", 2 x 3/4", 2 x 1"
connectors MBH-10/20 089019
4 x 3/4", 4 x 1" knockouts MBH-15/20 089021
Slab Box with Molded Connectors (Hubs)
KWIKON®SLAB BOXES
Kwikon Slab Boxes
Engineered to be rugged and durable, Kwikon slab boxes
withstand construction’s harshest environments. Designed by
contractors for contractors, Kwikon slab boxes are available in two
unique styles, with or without molded connectors. Now you can
provide a complete, nonmetallic slab system. priced competitively
with traditional steel mud boxes, Kwikon slab boxes increase
labor efficiencies, reducing costs.
Standard Slab Boxes
Hub Size (in) Part Number Product Code
8 x 1/2 SMB-H-10 089465
8 x 3/4 SMB-H-15 089462
4 x 1/2, 4 x 3/4 SMB-H-10/15 089458
4 x 1/2, 2 x 3/4, 2 x 1 SMB-H-10/20 089466
4 x 3/4, 4 x 1 SMB-H-15/20 089464
Knockout Size (in) Part Number Product Code
8 x 1/2 SMB-10 089460
4 x 1/2, 2 x 3/4, 2 x 1 SMB-10/20 089461
Hub Size (in) Part Number Product Code
8 x 1/2 SSBH-10 089467
8 x 3/4 SSBH-15 089468
4 x 1/2, 2 x 3/4, SSBH-10/15 089469
4 x 1/2, 2 x 3/4, 2 x 1 SSBH-10/20 089474
4 x 3/4, 4 x 1 SSBH-15/20 089475
4" Square Slab Box
Slab Box with Molded Connectors
Slab Box without Molded Connectors
Slab Box with Molded Connectors
• Approved for support of ceiling fans up to 35 lbs and
luminaries up to 50 lbs
• Corner and traditional mounting tabs offer contractors two
options when installing to the slab deck
• Angled design guides the nail into position within the trim
cover area
• Ready to install – no assembly required
• Clear Vue vacuum formed removable covers
8180
KWIKON ENT
KWIKON ENT
KWIKON®SLAB BOXES
KWIKON®SLAB BOXES
KSB-10/15 KDSB-2-10/15
KVP KFC-10 KWBC-10
KDCB-10/15
KCB-10
KRCD-2-10 KRCD-2-15
KDSB-2-10
KRC-10 KRC-15
ENT Wall Boxes, Ceiling Boxes & Covers
Size (in) Part Number Product Code
Ceiling Box 2-1/16" Deep KCB-10 089506
4" Set-Up Box 2-1/16" Deep KDCB-10/15 089507
Switch Box 3-1/16" Deep KSB-10/15 089508
4" Square Box 1-1/2" Deep KDSB-2-10 089509
4" Square Box 2-1/8" Deep KDSB-2-10/15 089510
Raised 1/2" Single Device KRC-10 089501
Raised 5/8" Single Device KRC-15 089502
Raised 1/2" Two Devices KRCD-2-10 089503
Raised 5/8" Two Devices KRCD-2-15 089504
Round Flat Cover, 1/2" KO KFC-10 089505
Square Flat Cover, 1/2" KO KWBC-10 089500
Voltage Partition KVP 089512
Size (in) Part Number Product Code
4 x 1/2 & 4 x 3/4 SVDB-H-10/15 089496
4 x 3/4 & 4 x 1 SVDB-H-15/20 089049
4 x 1/2, 2 x 3/4, 2 x 1 SVDB-H-10/20 089052
8 x 3/4" SVDB-H-15 089065
Hub Size (in) Part Number Product Code
4 x 1/2 SVSB-H-10 089054
4 x 3/4 SVSB-H-15 089053
Concrete Wall Box
3-1/2" Deep Boxes
2" Shallow Boxes
• Fully assembled and installation ready
• Perfectly suited for deep or shallow construction preferences
• Concrete-tight poly film covering the box opening
• Kwikon hubs do not protrude inside the box
• Clear Vue vacuum formed removable covers
Floor Box Stand Kit
includes FB Box
Is equiped with several height brackets which accommodate
the different rebar and post-tension cable heights and slab
depths found from job-site to job-site.
Product Code Part Number
FBS-KIT
FBS-KIT 077700
For full product selection see page 51
SHORT FORM SAMPLE SPECIFICATIONS 83
82 SHORT FORM SAMPLE SPECIFICATIONS
KWIKON ENT
KWIKON ENT
Short Form Sample Specification
General
References:
Standards referred to in this section are:
UL 1653 Electrical Nonmetallic Tubing
NEMA TC-13 Electrical Nonmetallic Tubing
Products
Manufacturers:
Acceptable manufacturers are listed below:
Electrical Nonmetallic Tubing - Kwikon by IPEX
Electrical Nonmetallic Tubing Fittings - Kwikon by IPEX
Electrical Nonmetallic Tubing Boxes - Kwikon by IPEX
All ENT tubing, ENT fittings, ENT boxes and accessories shall be
manufactured by the same company so as to form a complete
ENT system.
ENT systems shall be approved for use in fire resistance rated
concrete floor-ceiling assemblies with fire resistance ratings up
to 4 hours.
Raceways:
ENT raceway shall be color coded to indicate the wiring system.
Blue stripe for power, red stripe for fire alarm/emergency
systems and yellow stripe for data/communications.
ENT raceway shall be listed to UL1653 and manufactured in
accordance with NEMA TC-13.
Fittings:
ENT fittings shall be manufactured of high impact PVC
ENT fittings requirements:
Provide fittings meeting the following requirements:
Six locking tabs located every 60º proving 360º contact
Locking tabs shall provide a pullout of a minimum
175 ft-lb force
Concrete tight without the need for taping
When transitioning to EMT conduit, the transition fitting
shall have six locking tabs for ENT connection and set-
screw connection for EMT
Boxes:
ENT boxes shall be manufactured of high impact PVC
ENT slab box and wall box requirements:
Slab boxes shall be approved for the purpose and
concrete-tight
Round slab boxes shall be approved for use with
luminaries up to 50 lbs. and ceiling fans up to 35 lbs.
Round slab boxes shall have threaded brass inserts for
the attachment of luminaries or ceiling fans
Slab boxes shall have eight (8) integrally molded ENT
hub connectors with six locking tabs for ENT raceway
connection
Installation
ENT raceways, fittings, boxes and accessories shall be
installed in accordance with Article 362 of the 2002 National
Electrical code.
Where ENT penetrates a fire rated wall, floor or ceiling
assembly, an approved firestop system as listed in
Underwriters Laboratories Building Materials Directory or other
nationally recognized testing laboratory shall be used.
Not permitted for use where subject to ambient temperatures
in excess of 122ºF (50ºC).
INEXO®ICF BOX 85
INEXO ICF BOX
INEXO®Electrical Boxes - the only approved
electrical box for ICF construction!
Available in commercial and residential styles.
THE INNOVATIVE ELECTRICAL BOX FOR
INSULATED CONCRETE FORM CONSTRUCTION
Insertion depth
of 2-1/4"
Insertion depth
of 2-1/4"
Full flange prevents box
from twisting and
sinking into foam if
over-tightened
Full flange prevents box
from twisting and
sinking into foam if
over-tightened
‘TEETH’ can be
easily removed
and replaced
‘TEETH’ can be
easily removed
and replaced
‘TEETH’ lock in
place providing a
rigid hold in the
EPS foam
‘TEETH’ lock in
place providing a
rigid hold in the
EPS foam
Greater installation versatility
with 3 screw hole choices and
flanges on both sides
Greater installation versatility
with 3 screw hole choices and
flanges on both sides
INEXO provides a 1/2"
drywall setback resulting
in a professional finish
INEXO provides a 1/2"
drywall setback resulting
in a professional finish
Single gang box
provides 19 cubic inch
capacity
Single gang box
provides 19 cubic inch
capacity
INEXO Boxes for ICF Construction
Until now there have been few choices when attempting to provide a truly
professional electrical box solution for Insulated Concrete Form homes.
INEXO’s patented design provides a truly professional solution that
works with your production schedule and provides the quality installation
and finished look that builders require and owners appreciate. INEXO
boxes link seamlessly with existing ICF materials, tools and methods. A
complete offering designed for ICF walls allow builders to standardize
on the use of electrical boxes throughout the building.
Residential (NMD Cable 14/2 – 10/3)
Commercial (AC or NMD Cable)
Description Part Number Product Code
Single Gang ICF-1-RL 220000
Double Gang ICF-2-RL 220001
Triple Gang ICF-3-RL 220002
Description Part Number Product Code
Single Gang ICF-1-CLU 220009
Double Gang ICF-2-CLU 220010
Triple Gang ICF-3-CLU 220011
87
SUPER DUCT
SUPER DUCT®
SUPERDUCT: Telephone, Power &
Communications Duct
Super Duct is recognized by major utilities, contractors and
engineering firms as the premier ducting product available on
the market.
Super Duct is manufactured with a specialized compound and
engineered for high impact and crush strength specifically
required by utilities for underground duct. This compound
enhances the friction coefficient of Super Duct for easier
pulling of conductors/wires through long runs.
UL 651
NOTES
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
8988
SUPER DUCT
SUPER DUCT
ENGINEERING DATA
Field Bending
The natural flexibility of IPEX Super Duct allows field
bending, so minor changes in elevation or direction can
often be accommodated without the use of special sweeps or
fittings. The following table indicates typical maximum
offset bends that can be achieved by “cold bending.”
Offset
Allowable Offset for Super Duct
NOTES:
1. Axial deflection should not be attempted at the joints.
2. The above values were established for ambient temperatures above
the freezing point. Increased radii may be desirable at below-freezing
temperatures.
Size
inches Max Allowable Offset
10' Length (inches) Max Allowable Offset
20' Length (inches)
220 79
314 56
3-1/2 12 49
411 43
5 7 35
6 7 29
ADVANTAGES
Lightweight
Super Duct is easy to carry and install, reducing labor and costs.
Long Lengths
Super Duct is available in 10' and 20' lengths, minimizing the
number of connections needed.
Bell Ends
Super Duct is bell-ended, allowing for easy assembly in the field.
High Compressive Strength
Super Duct’s specially formulated compound is designed to
withstand high loads.
Low Coefficient of Friction
The smooth bore of Super Duct facilitates cable pulling and
eliminates costly cable damage.
Quality Control
Stringent, continuous testing ensures that Super Duct is a
consistently high quality product.
9190
SUPER DUCT
SUPER DUCT
Concrete Encased Monolithic Installation
For multipurpose power cable and communication duct banks,
spacing between ducts is critical for optimum performance.
IPEX offers Vertical Lok Spacer systems to accommodate all
specification and field installations.
These lightweight spacers provide the
vertical and horizontal separation required
in a trench.
With spacers in place on trench bottom,
lay the first tier of ducts. When using a
concrete base, lay the bottom tier before
the base has taken initial set. Place
subsequent tiers of spacers on top of the
tier until the required number of ducts are
installed. Then tie the entire assembly
together. It is not necessary to weight or
brace the bank unless the concrete mix is
very wet.
The Concrete Pour
Do not allow a heavy mass of concrete to fall directly onto the
duct. If this is a possibility, use a plank to direct the concrete
down the sides of the bank assembly to the trench bottom. The
concrete will flow to the center of the bank and rise up in the
middle, uniformly filling all open spaces. Voids can be
eliminated by carefully working a long, flat slicing bar or
spatula up and down between the vertical rows of ducts.
Concrete should then flow between and under all of the ducts.
Duct Bank Elevation
All spacers should be staggered. It is recommended that
spacers should be located approximately one-fifth of duct
length from each end. Vertical Lok spacers should be located
to a maximum of every 5.5 ft.
Backfilling
Backfill with regular excavated soil after the concrete has set.
INSTALLATIONENGINEERING DATA
Bends
Pipe Dia. Radius of Bend (R)
(in) 24" 36" 48" 60"
290° / 45° / 22-1/2°
390° / 45° / 22-1/2°
490° / 45° / 22-1/2°
590° / 45° / 22-1/2°
690° / 45° / 22-1/2°
90° 45° 221/2°
Static Friction Coefficient
Ducting Materials
.0 .1 .2 .3 .4 .5 .6 .7 .8
PVC
RTRC
9392
SUPER DUCT
SUPER DUCT
INSTALLATION
Direct Burial Installation
Trench Bottom
The trench bottom should provide a
continuous, firm and uniform support
for the duct bank construction. Care
should be taken to avoid lumps, ridges,
depressions and stones causing “point”
contacts or uneven bearing.
Rock or Shale
Excavate 3" below the desired depth and bring the trench back
to grade with selected tamped soil. This will provide the duct
with a uniform bedding surface.
Unstable Soils
Tests should be conducted to establish the soil strength in
marshy or swampy areas. It may be necessary in these
conditions to dig deeper and refill with crushed stone or
gravel, or to employ mats, timbers or a concrete base.
Placement of Duct
After the first tier of ducts is installed, backfill and compact
as outlined below. If wood combs are employed for spacing,
remove them as the backfill is placed and tamped. Then begin
the next tier.
Initial Backfilling
1.Fit side and center to the top of the ducts. Use a hand
tamper only to tamp firmly.
2.Backfill over the duct to the required thickness (see note)
and tamp firmly, using only a hand tamper.
Final Backfilling
When the last tier is placed, hand-place the backfill to 4" over
the duct with soil that does not contain stones larger than
3/8". Hand-tamping of this layer is optional, depending on the
specifications.
From this point, backfill may be completed by hand or by
pneumatic tamping in layers from 4" to 12" depending on the
degree of compaction desired.
When placing backfill by machine, avoid the use of large rocks
until a protective layer (minimum of 12") is established.
Note: In direct burial, no spacer should be used with Duct; spacers provide “point” support
instead of the continuous bed required. Backfill thickness between ducts is usually 2" to 3".
INSTALLATION
Concrete Encased Tier-by-Tier
Installation
The advantage of this method is the
production of a solid, void-free concrete
envelope. Simply pour each tier
independently.
Trench Bottom
After grading the trench, place a foundation of 3" of concrete
on the bottom. It should be smooth and graded.
Bank Assembly
Lay the bottom tier of ducts on the
concrete base. Ducts should be spaced
with wooden combs (two per duct
length). Concrete the first tier level to
the top of the comb. Remove combs
and fill the voids. Light tamping will
ensure an even surface. Repeat this
sequence until the bank is built up.
Concreting
If the concrete is allowed to set before assembling the next
tier, the concrete will be stronger and more dense and the
ducts will be aligned straighter. One problem with this method
is that the bank will be in a
series of layers and therefore more
likely to heave and
separate under frost conditions. If
successive tiers are laid before the concrete has set, a
satisfactory bond will be achieved by tamping the dry concrete.
Backfilling
Backfill with regular excavated soil when the bank is complete.
Duct is usually laid in 100' sections once the trench is
excavated. Therefore, concreting can be a continuous process.
Cross-section of
tier-by-tier method.
Type of wood comb used.
100'
100'
100' 100'
100'
9594
SUPER DUCT
SUPER DUCT
POWER & COMMUNICATION DUCT
Type EB-20
Rated For 90°C Cable / 20-Foot Length, Belled One End
Nominal
Size (in) Product
Code Average
OD Min. Wall Feet/Pallet Approx.
Wt/lbs
2008821 2.375 0.060 3,520 37
3008831 3.500 0.061 1,560 56
*4 008841 4.500 0.082 1,200 93
*5 008851 5.563 0.103 460 142
*6 008861 6.625 0.125 520 202
* UL Listed
Type DB-60
Rated For 90°C Cable / 20-Foot Length, Belled One End
Nominal
Size (in) Product
Code Average
OD Min. Wall Feet/Pallet Approx.
Wt/lbs
2008321 2.375 0.060 3,520 37
3008731 3.500 0.092 1,560 80
4008741 4.500 0.121 1,200 132
5008751 5.563 0.152 460 202
6008761 6.625 0.182 520 285
Type EB-35
Rated For 90°C Cable / 20-Foot Length, Belled One End
Type DB-120 Duct
Rated For 90°C Cable / 20-Foot Length, Belled One End
Nominal
Size (in) Product
Code Average
OD Min. Wall Feet/Pallet Approx.
Wt/lbs
2008921 2.375 0.060 3,520 33
3008931 3.500 0.076 1,560 64
4008941 4.500 0.100 1,200 105
5008951 5.563 0.126 460 161
6008961 6.625 0.152 520 230
Nominal
Size (in) Product
Code Average
OD Min. Wall Feet/Pallet Approx.
Wt/lbs
2008621 2.375 0.077 3,520 42
3008631 3.500 0.118 1,560 96
4008641 4.500 0.154 1,200 158
5008651 5.563 0.191 460 240
6008661 6.625 0.227 520 336
PVC Plastic Compounds.
Plastic Utilities Duct for Underground
Installation.
Smooth-Wall Poly (Vinyl-Chloride) (PVC)
conduit and Fittings for Underground
Installation.
ASTM D1784, ASTM F512
NEMA TC-6
95 POWER & COMMUNICATION DUCT
TELEPHONE DUCT
PVC Telephone Duct -
20 foot Length, Belled One End
Nominal
Size Product
Code Type Average
OD Min.
Wall Min.
ID Feet /
Pallet Approx.
lbs/ft
4008040 B4.350 0.091 4.13 1,260 1.0
4008041 B (HW) 4.350 0.101 4.11 1,260 1.1
4008042 C4.350 0.148 4.00 1,260 1.6
4008043 C X 10' 4.350 0.148 4.00 630 1.6
4008044 D4.350 0.148 4.00 1,260 1.6
Performance Properties
As indicated under Telephone Standard 8546
Telephone Duct
Type B, Type B(HW), Type C, Type D
Telephone Duct Type B and Type B – Heavy Wall are designed
for use in concrete-encased installations.
Telephone Duct Type C is designed for direct burial applications.
Telephone Duct Type D is designed for exposed and special
applications, and contains 6% titanium oxide for UV resistance.
Minimum
Impact Resistance Minimum Pipe
Stiffness Heat Distortion
48 hrs @ 140°F
Type @ 73.4ºF @ 32ºF Type lbs/in/in Type Load Max decr.
B50 ft.lbs. 25 ft.lbs. B30 B15 0.250"
B(HW) 50 ft.lbs. 25 ft.lbs. B (HW) 40 B (HW) 15 0.250"
C100 ft.lbs. 50 ft.lbs. C120 C60 0.250"
D150 ft.lbs. 75 ft.lbs. D120 D60 0.250"
97
SCEPTACON
SCEPTACONTM TRENCHLESS RACEWAY SYSTEMS
SceptaConTM Trenchless Raceway Systems
SceptaCon is one of the first PVC systems designed for the
rigors of trenchless applications. It links seamlessly to existing
PVC conduit infrastructures and allows utility companies to
standardize on PVC throughout their entire electrical systems.
SceptaCon's slide-in locking system and pre-installed, pre-
lubricated gaskets allow contractors to create a water-tight seal
by hand in seconds - in all temperatures - without having to
worry about solvents or chemicals freezing or drying too quickly.
Its unique spline-lock snaps into a recessed opening, ensuring
the spline won't get snagged during pull-through. SceptaCon's
rounded bell shoulders slide easily past roots, rocks and other
debris in the borehole, ensuring a smooth, easy installation.
And because SceptaCon is made to the same high standards as
our Scepter rigid PVC conduit, contractors and electrical
utilities can be assured of the same level of quality - above
ground and below.
&MUCH MORE ...
DOWNLOAD
OUR ELECTRICAL CATALOG
OR OUR SCEPTER
ELECTRICAL CATALOG
ONLINE TRAINING
TECHNICAL DOCUMENTS
PRODUCT INFO
Visit our website:
www.ipexamerica.com
+
Riser / Resi Straps
Size Part Number Product Code
3/4" KPS075 132006
1" KPS100 132007
1-1/4" KPS125 132008
1-1/2" KPS150 132009
2" KPS200 132010
Conduit Clamp & Spacers
Size (in) Part Number Product Code
1/2 CCS10 077794
3/4 CCS15 077796
1 CCS20 077797
1-1/4 CCS25 077798
1-1/2 CCS30 077799
2 CCS35 077800
Strut Base CCS-B 077343
The Conduit Clamp and Spacers are
engineered to accommodate proper
expansion and contraction of conduits and
to prevent unwanted clamp opening.
Manufactured of the same material as
Riser/RESI raceway, Kwikpath pipe straps
allow for compliance with installation requirements providing
for the proper support of Riser/RESI raceways.
99
KWIKPATH®COMMUNICATION RACEWAY SYSTEMS
98
SCEPTACON
SCEPTACONTM TRENCHLESS RACEWAY SYSTEMS
No Cementing or Lubrication
SceptaCon’s slide-in locking system and
pre-installed, pre-lubricated gaskets allow
contractors to create a water-tight seal by
hand in seconds.
Outperforms Other PVC
Products
SceptaCon’s unique spline-lock snaps into
a recessed opening, ensuring the spline
won’t get snagged during pull-through.
SceptaCon’s rounded bell shoulders slide
easily past roots, rocks and other debris in
the borehole, ensuring a smooth, easy
installation.
No Fusion Required
Because SceptaCon’s joints can be quickly
joined by hand in seconds, crews don’t
need large, expensive fusion equipment or
special training to create water-tight joints.
In addition, SceptaCon can be assembled
one pipe length at a time, then pulled
underground, eliminating the need for long
strings of pipe on the job.
Superior Performance
SceptaCon is made from durable schedule 40 PVC that’s
resistant to creasing, scoring or flattening when pulled past
obstructions in the borehole, yet flexible enough to bend with
underground twists and turns. SceptaCon remains round,
unlike HDPE which can stretch and become oval.
Easy to Handle
SceptaCon is available in
convenient 10' and 20'
lengths that are light-
weight, easy to handle and
no problem to work with in
all types of weather.
Length Product Code
2" x 20' 106221
3" x 10' 106330
3" x 20' 106331
4" x 10' 106340
4" x 20' 106341
5" x 10' 106350
5" x 20' 106351
6" x 10' 106360
6" x 20' 106361
SCEPTACONTM TRENCHLESS RACEWAY SYSTEMS
SCEPTACON
NOTES
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
NOTES
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
NOTES
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
____________________
Indoor use primarily to provide protection
against contact with the enclosed equipment
and against a limited amount of falling dirt.
Indoor use to provide a degree of protection
against limited amounts of falling water and dirt.
Outdoor use to provide a degree of protection
against windblown rain; undamaged by the
formation of ice on the enclosure.
Either indoor or outdoor use to provide a
degree of protection against falling rain,
splashing water, and hose-directed water;
undamaged by the formation of ice on the
enclosure.
Either indoor or outdoor use to provide a
degree of protection against falling rain,
splashing water, and hose-directed water;
undamaged by the formation of ice on the
enclosure; resists corrosion.
Indoor or outdoor use primarily to provide a
degree of protection against hose-directed
water, the entry of water during prolonged
submersion at a limited depth, and be
undamaged by the formation of ice on the
enclosure.
Indoor use to provide a degree of protection
against dust, dirt, fiber flyings, dripping water,
and external condensation of noncorrosive
liquids.
Indoor use to provide a degree of protection
and spraying of water, oil, and noncorrosive
liquids.
2
3
4
4X
12
13
6P
1 2 3 4 5 6 7 8
1
TYPE
DESIGNATION UL UNDERWRITERS LABORATORIES INC
(UL 50 AND UL 508)
This material is reproduced with permission from Underwriters
Laboratories Inc. Standard for Safety for Cabinets and Boxes, UL
50, Copyright 1988 and Industrial Control Equipment, UL 508,
Copyright 1994 by Underwriters Laboratories Inc.
Underwriters Laboratories Inc. (UL) shall not be responsible to
anyone for the use of or reliance upon a UL Standard by anyone.
UL shall not incur any obligation or liability for damages,
including consequential damages, arising out of or in connection
with the use, interpretation of, or reliance upon a UL Standard.
Company
Name
Title
Address
City State Zip
Phone ext.
Fax E-mail / Website
This is a:
Home Address Business Address Jobsite Address
Business Type:
(check 1 or 2 that best apply)
Company Classification:
Distributor/Wholesaler
Engineering Firm
Contractor
Government
OEM - Products Manufactured:_______________________
Other:_____________________________________________
SIC or industry sector:__________________________________
My primary markets are (check all that apply):
Tel: (905) 403-0264
Toll Free: (800) 463-9572
Fax: (905) 403-1124
Website: www.ipexamerica.com
IPEX
2441 Royal Windsor Drive
Mississauga, Ontario, Canada
L5J 4C7
PLEASE PRINT
Register your Pocket Pro today!
Fax this form to (905) 403-1124 and we’ll add
you to our mailing list.
Commercial
Residential
Industrial
Other:_________________
Utility
OEM
Institutional
This literature is published in good faith and is believed to be reliable.
However, it does not represent and/or warrant in any manner the
information and suggestions contained in this brochure. Data presented is
the result of laboratory tests and field experience.
A policy of ongoing product improvement is maintained. This may result
in modifications of features and/or specifications without notice.
CTELNAIP130709 © 2013 IPEX EL004U
Customers call
IPEX USA LLC
Toll free: (800) 463-9572
www.ipexamerica.com
CUSTOMER SERVICE CENTER
www.ipexamerica.com
DISTRIBUTED BY:
Products manufactured by IPEX Electrical Inc. and distributed in the United
States by IPEX USA LLC.
INEXO®, Kwikflex®, Kwikon®, SceptaConTM, SceptalightTM and SuperDuct®are
trademarks of IPEX Branding Inc. Pocket Pro
ELECTRICAL SYSTEMS
Trenchless Raceways Systems
® TMTM
®
®
®
www.ipexamerica.com
About the IPEX Group of Companies
As leading suppliers of thermoplastic piping systems, the IPEX Group of
Companies provides our customers with some of the world’s largest and most
comprehensive product lines. All IPEX products are backed by more than
50 years of experience. With state-of-the-art manufacturing facilities and
distribution centers across North America, we have established a reputation
for product innovation, quality, end-user focus and performance.
Markets served by IPEX group products are:
Electrical systems
PVC, CPVC, PP, PVCO, ABS, PEX, FR-PVDF and PE pipe and fittings (1/4"
to 48")
Industrial process piping systems
Municipal pressure and gravity piping systems
Plumbing and mechanical piping systems
PE Electrofusion systems for gas and water
Industrial, plumbing and electrical cements
Irrigation systems
®