Baldor DC Motor Controls MotionUSA Your Source For High Speed And Precision
2014-11-11
: Pdf 648049-Attachment 648049-Attachment 781568 Batch12 unilog
Open the PDF directly: View PDF .
Page Count: 24
Download | |
Open PDF In Browser | View PDF |
DC Motors & Controls Farm Duty Motors Subfractional Permanent Magnet DC Motor - TENV, Rigid Base 1/50 thru 1/4 Hp Definite Purpose Motors Applications: General purpose including conveyors, material handling equipment and packaging machinery. Features: High quality ball bearing motors with precision machined die cast aluminum or steel housings. Dynamically balanced for smooth, vibration-free operation. Unit Handling Motors Brake Motors Input Motor Hp Output Base Speed Voltage Direct Current Armature Full Load Amperage Armature Catalog Number List Price Mult. Sym. Gear Style Ap’x. Shpg. Wgt. Notes (a) 1/50 1/25 1800 1725 1/15 1800 1/8 1725 1/4 3450 90 90 90 180 90 180 90 180 0.3 0.5 0.8 0.4 1.3 0.7 2.5 1.3 AP231001 AP232001 AP233001 AP233021 AP7401 AP7421 AP7402 AP7422 294 322 346 346 484 484 484 484 DS DS DS DS DS DS DS DS 2308P 2314P 2318P 2318P 2424P 2424P 2424P 2424P 4 5 5 5 12 12 12 12 20,60 20,60 20,60 20,60 20,60 20,60 20,60 20,60 NOTE: Supplied with type SJO, three foot 18/3 AWG grounded cord. (a) See notes on inside back flap. 200 & 575 Volt Motors SCR Drive Permanent Magnet Motor TENV and TEFC, C-Face with Base 1/4 thru 5 Hp Applications: Conveyors, mixers, packaging machinery. Features: NEMA C-face with removable base. Tach adaptable. Class F insulation, double sealed ball bearings. 20:1 constant torque speed range. UL and CSA recognized. 1/4 - 1/2 Hp motors are TENV, all others are TEFC. No dual mounting base holes on 1/4 - 1/2 Hp. IEC Frame Motors 50 Hertz Motors Inverter/Vector Motors & Controls Base Speed NEMA Frame 1/4 1750 56C 1/3 1750 56C 1750 56C 2500 56C 1750 56C 2500 56C 1750 56C 2500 56C 1750 2500 1750 2500 1750 145TC 145TC 145TC 145TC 182TC 182C 1810ATC Hp 1/2 3/4 DC Motors and Controls Soft Start & Dynamic Brakes 238 1 1 1/2 2 3 5 1750 NEMA 56C thru 1810ATC Voltage D.C. Full Load Amperage Arm. Arm. 90 180 90 180 90 180 90 90 180 90 90 180 90 180 180 180 180 180 180 180 180 2.5 1.25 3.2 1.6 4.8 2.5 5 7.6 3.7 7.5 10 5 9.7 4.85 7.7 7 9.6 10 14 14 21.6 Enclosure Catalog Number List Price Mult. Sym. Ap’x. Shpg. Wgt. Notes (a) TENV TENV TENV TENV TENV TENV TENV TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC CDP3310 CDP3306 CDP3320 CDP3316 CDP3330 CDP3326 CDP3335 CDP3440 CDP3436 CDP3443 CDP3445 CDP3455 CDP3450 CDP3460 CDP3575 CDP3580 CDP3585 CDP3590 CDP3603 CDP3604 CDP3605 695 695 733 733 820 820 733 996 996 881 1,211 1,211 996 996 2,231 1,941 2,662 2,231 3,278 3,260 5,564 K K K K K K K K K K K K K K L1 L1 L1 L1 L1 L1 L1 24 23 27 27 32 31 26 38 38 36 44 44 38 38 65 53 74 66 112 112 161 20,60 20,60 20,60 20,60 20,60 20,60 20,60 20 20 20 20 20 20 20 20 20 20 8 20 20 20 NOTE: See Tach Generators on page 254 and Mounting Kits on page 255. (a) See notes on inside back flap. Reliance M/N T56S1001 T56S1003 T56S1005 T56S1027 T56S1006 T56S1009 T56S1029 T56S1011 T56S1013 T56S1012 1750 56C 1/2 1750 56C 3/4 1750 56C 1 1750 56C 1 1/2 2 3 5 1750 1750 1750 1750 143TC 143TC 182ATC 1810ATC 90 180 90 180 90 180 90 180 90 180 180 180 180 180 2.5 1.25 3.2 1.6 4.8 2.5 7.6 3.7 10 5 7.7 9.6 14 24.5 List Price Mult. Sym. Ap’x. Shpg. Wgt. Notes (a) TENV TENV TENV TENV TENV TENV TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC CDPT3310 CDPT3306 CDPT3320 CDPT3316 CDPT3330 CDPT3326 CDPT3440 CDPT3436 CDPT3445 CDPT3455 CDPT3575 CDPT3585 CDPT3603 CDPT3605 1,984 1,984 2,024 2,024 2,151 2,151 2,275 2,275 2,538 2,538 3,523 3,953 4,598 6,878 K K K K K K K K K K L1 L1 L1 L1 27 27 30 30 35 36 44 45 50 50 71 79 122 164 20,60 20,60 20,60 20,60 20,60 20,60 20 20 20 20 20 20 20 20 Explosion Proof Permanent Magnet SCR Drive Motor - TEFC, C-Face with Base 1/4 thru 1 1/2 Hp IEC Frame Motors (a) See notes on inside back flap. NEMA 56C thru 145TC Applications: Conveyors, feeders, and pumps (adjustable speed and constant torque for hazardous locations). Features: NEMA C-Face with welded on base. 20:1 constant torque speed range. UL and CSA. Division 1, Class I, Group D; Class II, Group F & G, T3C. Thermostat and explosion proof conduit box included. Not tach adaptable. Base Speed NEMA Frame 1/4 1750 56C 1/3 1750 56C 1/2 1750 56C 3/4 1750 56C 1 1750 56C 1 1/2 1750 145TC Hp Brake Motors 1/3 Arm. Catalog Number 200 & 575 Volt Motors 56C Arm. Enclosure Voltage D.C. Full Load Amperage Arm. Arm. 90 180 90 180 90 180 90 180 90 180 180 2.7 1.3 3.6 1.7 5.2 2.5 7 3.5 9.6 4.9 7.1 Catalog Number XP Cls/Grp Temp Code List Price Mult. Sym. Ap’x. Shpg. Wgt. Notes (a) CDPX3410 CDPX3406 CDPX3420 CDPX3416 CDPX3430 CDPX3426 CDPX3440 CDPX3436 CDPX3545 CDPX3555 CDPX3575 ② ② ② ② ② ② ② ② ② ② ② T3C T3C T3C T3C T3C T3C T3C T3C T3C T3C T3C 1,907 1,907 2,396 2,396 2,705 2,705 3,344 3,344 4,454 4,454 4,761 K K K K K K K K K K L1 38 38 43 44 46 46 51 51 73 71 81 20, 59 20, 59 20, 59 20, 59 20, 59 20, 59 20, 59 20, 59 20, 59 20, 59 20, 59 50 Hertz Motors 1750 Full Load Amperage Inverter/Vector Motors & Controls 1/4 Voltage D.C. DC Motors and Controls NEMA Frame Soft Starters & Dynamic Brakes Base Speed Hp Unit Handling Motors speed range with NEMA Type K control. 1/4 - 1/2 motors are TENV, all others are TEFC. Definite Purpose Motors 1/4 thru 5 Hp NEMA 56C thru 1810ATC Integral DC Tach Permanent Magnet SCR Applications: Conveyors and metering pumps (precise speed regulation). Drive Motor Features: Provides an integral 50 VDC per 1000 RPM precision tachometer TENV and TEFC, for closed loop drive system. Class F insulation. 20:1 constant torque C-Face with Base Farm Duty Motors DC Motors & Controls ② Class I, Group D; Class II, Group F&G CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. 239 DC Motors & Controls Farm Duty Motors Definite Purpose Motors Washdown Duty Permanent Magnet SCR Drive Motor - TENV and TEFC, C-Face with Base Unit Handling Motors Base Speed NEMA Frame 1/4 1750 56C 1/3 1750 56C 1/2 1750 56C 3/4 1750 56C 1 1750 56C 1 1/2 2 3 5 1750 1750 1750 1750 145TC 145TC 182TC 1810ATC Hp Brake Motors 200 & 575 Volt Motors IEC Frame Motors 50 Hertz Motors NEMA 56C thru 1810ATC Applications: Food processing conveyors and feeders exposed to high pressure wash down. Features: Moisture sealant on bolt heads between frame and endplates, neoprene gasketed conduit box. Double sealed ball bearings. Forsheda® running contact v-ring slinger. Stainless steel shaft. Electrostatic epoxy paint coating. Class F insulation. 20:1 constant torque speed range. Tach adaptable. 3300P motors are TENV, all others are TEFC. Voltage D.C. Full Load Amperage Arm. Arm. 90 180 90 180 90 180 90 180 90 180 180 180 180 180 2.5 1.25 3.2 1.6 4.8 2.5 7.6 3.7 10 5 7.7 9.6 14 24.5 Enclosure Catalog Number List Price Mult. Sym. Ap’x. Shpg. Wgt. Notes (a) TENV TENV TENV TENV TENV TENV TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC CDPWD3310 CDPWD3306 CDPWD3320 CDPWD3316 CDPWD3330 CDPWD3326 CDPWD3440 CDPWD3436 CDPWD3445 CDPWD3455 CDPWD3575 CDPWD3585 CDPWD3603 CDPWD3605 900 900 950 950 1,068 1,068 1,289 1,289 1,572 1,572 3,008 3,590 4,595 7,783 K K K K K K K K K K L1 L1 L1 L1 25 24 27 27 32 32 38 38 44 44 66 75 116 157 20,60 20,60 20,60 20,60 20,60 20,60 20 20 20 20 20 20 20 20 NOTE: See Tach Generators on page 254. Mounting kits on page 255. (a) See notes on inside back flap. Paint Free Washdown Duty Permanent Magnet SCR Drive Motor, TEFC, C-Face with Base Inverter/Vector Motors & Controls DC Motors and Controls Soft Start & Dynamic Brakes 240 1/4 thru 5 Hp Base Speed NEMA Frame 1/4 1750 56C 1/2 1750 56C 1 1750 56C Hp (a) See notes on inside back flap. 1/4 thru 1 Hp NEMA 56C Applications: Food processing, packaging exposed to high pressure washdown with caustic solutions. Features: Class F insulation; 20:1 constant torque speed range. Moisture resistant 200°C magnet wire. Sealed ball bearings with moisture resistant grease. Contact lip seals on shaft extensions. Neoprene gaskets. Special processed endplates. 300 series stainless steel motor frame, base, shaft and hardware. No exterior paint. Not tach adaptable. Voltage D.C. Full Load Amperage Arm. Arm. 90 180 90 180 90 180 2.7 1.3 5.2 2.5 9.6 4.9 Catalog Number List Price Mult. Sym. Ap’x. Shpg. Wgt. Notes (a) CDPSWD3410 CDPSWD3406 CDPSWD3430 CDPSWD3426 CDPSWD3545 CDPSWD3555 1,077 1,077 1,276 1,276 1,886 1,886 K K K K K K 29 28 37 38 63 63 20 20 20 20 20 20 IEC D63 thru D112D Applications: Metric SCR Drive Motor replacement. Features: Metric Flange or C-Face per IEC 60072-1 Standards. Bolt on non-metric base. Class F insulation. Tach adaptable except type 15kW. 20:1 constant torque speed range. Conforms to IEC 60034-1. Definite Purpose Motors 0.15 thru 5 kW 0.2 thru 3.7 Hp 1.1/1.5 1.5/2 2.2/3 3.7/5 .15/.20 .18/.25 .25/.33 1.37/.50 .56/.75 .75/1 1.1/1.5 1.5/2 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 1.1 1.25 1.6 2.5 2.5 3.7 3.6 5 5.1 7.7 7.7 9.6 10 14 24.5 D63D D71C D71C D71C D71C D80C D80C D80C D80C D80C D90C D90C D90C 180 180 180 180 180 180 180 180 180 180 180 180 180 1.1 1.4 1.7 2.5 2.5 3.6 3.7 5.1 5 7.7 7.7 10.0 9.6 1800 1750 1750 3000 1750 3000 1750 3000 1750 3000 1750 3000 1750 B5 Flange TENV TENV TENV TENV TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC B14 Face TENV TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC Mult. Sym. Ap’x. Shpg. Wgt. Notes (a) VP7424D VP3311D VP3316D VP3326D VP3428D VP3436D VP3439D VP3455D VP3458D VP3468D VP3575D VP3585D VP3588D VP3603D VP3605D 485 695 733 820 850 996 881 1,211 996 1,110 2,244 2,677 2,244 3,294 5,592 DS K K K K K K K K L1 L1 L1 L1 L1 L1 10 23 27 31 33 40 37 46 41 47 71 78 69 121 166 60 20,60 20,60 20,60 20 20 20 20 20 20 20 20 20 20 20 VP7424-14 VP3411-14 VP3416-14 VP3428-14 VP3426-14 VP3439-14 VP3436-14 VP3458-14 VP3455-14 VP3468-14 VP3575-14 VP3588-14 VP3585-14 485 781 832 850 881 881 996 996 1,211 1,110 2,244 2,244 2,677 DS K K K K K K K K L1 L1 L1 L1 10 30 31 31 37 35 40 38 45 43 73 70 80 60 20 20 20 20 20 20 20 20 20 20 20 20 NOTE: Above motors D71 and larger with B5 flange, fitted with oil seal. Catalog numbers VP7424D and VP7424-14 are not tach adaptable. Tach Generators are shown on page 254. Tach Mounting Kits are shown on page 255. (a) See notes on inside back flap. 200 & 575 Volt Motors D63D D71D D71D D71D D71D D80D D80D D80D D80D D90D D90D D90D D90D D112D D112D 1800 1750 1750 1750 3000 1750 3000 1750 3000 3000 1750 1750 3000 1750 1750 List Price IEC Frame Motors .75/1 Arm. Catalog Number 50 Hertz Motors .57/.75 Arm. Enclosure Inverter/Vector Motors & Controls .37/.5 Full Load Amperage NEMA Frame DC Motors and Controls .15/.20 .18/.25 .25/.33 Voltage D.C. Base Speed Soft Starters & Dynamic Brakes kW/Hp Brake Motors Unit Handling Motors Metric Flange Permanent Magnet SCR Drive Motor, TENV and TEFC, Flange and Face Mount Farm Duty Motors DC Motors & Controls 241 DC Motors & Controls Farm Duty Motors Low Voltage Permanent Magnet Motor TENV and TEFC 1/4 thru 1 Hp Applications: Battery operation for portable pumps, fans, augers, winches and lifts. Definite Purpose Motors Unit Handling Motors Brake Motors 200 & 575 Volt Motors IEC Frame Motors Features: NEMA C-face, Class F insulation, double sealed ball bearings. Top-mounted terminal studs for power connection on ratings 40-amps and up. Not tach adaptable. 1/4 - 1/2 Hp are TENV, 3/4 - 1 Hp are TEFC. Hp Base Speed NEMA Frame 1/4 1800 56C 1/3 1800 56C 1/2 1800 56C 3/4 1800 56C 56CZ 1 1800 56C Voltage D.C. Full Load Amperage Catalog Number List Price Mult. Sym. Ap’x. Shpg. Wgt. Notes (a) 12 24 12 24 12 24 12 24 12 24 22.5 10.6 28.6 13.6 40 19.6 66 29.4 85.6 34.2 CDP3410-V12 CDP3410-V24 CDP3420-V12 CDP3420-V24 CDP3430-V12 CDP3430-V24 CDP3440-V12 CDP3440-V24 CDP3445-V12 CDP3445-V24 747 708 820 782 850 810 1,220 845 1,765 1,757 K K K K K K K K K K 23 23 31 31 37 35 42 41 45 46 20,60 20,60 20,60 20,60 20,60 20,60 20 20 20 20 (a) See notes on inside back flap. DC Power Motor TEFC, Rigid Base 1/3 thru 1 1/2 Hp NEMA 56 thru 184 Applications: Cranes, hoists, conveyors, augers and marine duty DC applications. Powered from generators or batteries. Features: 20% Compound Wound. Weather proof, meets IEEE 45 specifications. Suitable for mounting in any position. Continuous duty. Easy access brushes. Not tach adaptable. 50 Hertz Motors Inverter/Vector Motors & Controls DC Motors and Controls Soft Start & Dynamic Brakes 242 NEMA 56C Hp Speed NEMA Frame Rated Current 1/3 1/2 3/4 1 1750 1750 1750 1750 56 56 56 56 3.2 4.8 6.6 8 1/3 1/2 3/4 1 1 1/2 1750 1750 1750 1750 1750 56 56 56 56 184 1.7 2.1 3.3 4 6.1 Catalog Number 115 VDC D1151 D1152 D1153 D1154 230 VDC D2301 D2302 D2303 D2304 D2305 NOTE: Not for SCR control applications. Base welded on 3513D type only. Not tach adaptable. (a) See notes on inside back flap. List Price Mult. Sym. Ap'x Shpg. Wgt. Notes (a) 1,358 1,452 1,705 2,005 K K K K 23 29 34 62 20 20 20 20 1,358 1,455 1,705 2,005 3,521 K K K K L1 41 29 34 62 84 20 20 20 20 20 1/4 thru 3 Hp NEMA 56C thru 215C 1/4 1750 56C 1/3 1750 56C 1/2 1750 56C 3/4 1750 56C 1 1750 56C 182C 1 1/2 1750 2 1750 3 1750 182C 182C 213C 184TC 215C Voltage D.C. Full Load Amperage Arm. Field Arm. Field 90 90 180 90 90 180 90 90 180 90 180 90 180 90 180 180 180 180 180 100/50 100/50 200/100 100/50 100/50 200/100 100/50 100/50 200/100 100/50 200/100 100/50 200/100 100/50 200/100 200/100 200/100 200/100 200/100 3 3.4 1.9 3.7 5.7 2.6 5 7.8 3.9 8 5 10 5 9.6 7.5 9.5 9.5 14.7 14.7 .3/.6 .4/.8 .21/.42 .5/1 .5/1 .25/.5 .44/.88 .6/1.2 .3/.6 .6/1.2 .3/.6 .6/1.2 .25/.5 .55/1.1 .25/.5 .4/.8 .4/.8 .6/1.2 .6/1.2 Catalog Number List Price Mult. Sym. Ap’x. Shpg. Wgt. CD3425 CD3433 CD3434 CD5333 (b)(c) CD3450 CD3451 CD5350 (c) CD3475 CD3476 CD5375 (c) CD5318 (c) CD5319 (c) CD6218 CD6219 CD6215 CD6202 CD7502 CD6203 CD7503 699 764 764 1,101 868 868 1,216 1,080 1,080 1,432 1,525 1,525 2,037 2,037 2,281 2,698 4,734 3,064 5,035 K K K K K K K K K K K K L1 L1 L1 L1 L1 L1 L1 23 24 24 31 29 29 38 34 34 45 54 53 65 66 84 98 105 135 137 Notes (a) Brake Motors NEMA Frame 200 & 575 Volt Motors Base Speed Hp Unit Handling Motors Features: Designed for use with NEMA Type K SCR control, 20:1 constant torque speed range (except where noted). NEMA C-face and removable base. NEMA 182 frame and larger have a normally closed thermostat on the field winding. Class F insulation, 1.0 service factor. Definite Purpose Motors Applications: Conveyors, printing, textile equipment, machine tools (adjustable speeds with constant torque). 8, 73 IEC Frame Motors Shunt Wound SCR Drive Motors, TEFC, C-Face with Base Farm Duty Motors DC Motors & Controls 1/2 thru 2 Hp NEMA 182CZ thru 182C Features: Designed for use with NEMA Type K SCR control, 20:1 constant torque speed range. Normally closed thermostat on the field winding. Class F insulation, 1.0 service factor. UL and CSA Division 1, Class I, Group D, Class II, Group F & G. Full Load Amperage Catalog Number NEMA Frame 1/2 1750 182CZ 3/4 1750 182CZ 90 100/50 7 .55/1.1 CDX1875 (b) 182CZ 180 200/100 5 .25/.5 CDX2001 (b) 182C 180 200/100 5 .25/.5 CDX7100 Arm. Field Arm. Field XP Cls/Grp Temp Code List Price Explosion-Proof - Continuous Duty - Division 1, Class I, Group D & Class II, Group F & G - 1.0 S.F. 90 100/50 4.9 .55/1.1 CDX1850 (b) 2,768 ② T3B 1 1750 1 1/2 1750 182C 180 200/100 7.5 .25/.5 CDX7150 2 1750 182C 180 200/100 9.5 .4/.8 CDX7200 (b) ② ② ② ② ② T3B T3B T3B T3B T3B Mult. Sym. Ap’x. Shpg. Wgt. L1 100 3,666 L1 100 4,560 L1 102 3,785 L1 102 5,012 L1 121 5,629 L1 135 Notes (a) (a) See notes on inside back flap. ② Class I, Group D; Class II, Group F&G (b) Refers to shaft and/or face mounting dimensions only. Base mounting dimensions and shaft height differ from NEMA frames shown. Go to www.baldor.com for details. DC Motors and Controls Voltage D.C. Base Speed Hp Inverter/Vector Motors & Controls Applications: Conveyors, printing, textile equipment, machine tools (adjustable speeds with constant torque). Soft Starters & Dynamic Brakes Shunt Wound SCR Drive Motors, Explosion Proof TEFC, C-Face with Base 50 Hertz Motors NOTE: See Tach Generators on page 254 and Mounting Kits on page 255. Tach Mounting Kits are not available for explosion-proof motors. (a) See notes on inside back flap. (b) Base welded on type 3513D only. (c) No dual mounting base holes on 35D, 75D or 91D type. CAUTION: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. 243 DC Motors & Controls Farm Duty Motors Definite Purpose Motors RPM III DC Shunt Wound SCR Drive Motors, 180V Armature Power Code K Unit Handling Motors Brake Motors 200 & 575 Volt Motors Hp Base Speed NEMA Frame 1.5 2 1750 1750 3 1750 5 1750 DC189ATY (c) DC189ATY (c) DC1811ATCZ (d) DC189ATY (c)(e) DC189ATCZ (d)(e) DC1810ATCZ (d)(e) DC2112ATCZ (d) Voltage D.C. IEC Frame Motors 50 Hertz Motors Arm. Field 180 180 180 180 180 180 180 100/200 100/200 100/200 100/200 100/200 100/200 100/200 NEMA 189ATY thru 2112ATCZ Applications: Metals, paper, web processes, extruders, cranes, conveyors, packaging, printing, machine tools. Features: Unique laminated square frame for improved commutation on rectified power supplies. The square configuration allows for increased rating per frame size. Class F rated insulation system. Service Line brushes with convenient wear indicating reference lines. PLS™ (Positive Lubrication System) for longer bearing and motor life. F-3 mounting. Tach adaptable with thermostat. Full Load Amperage Enclosure Catalog Number List Price Mult. Sym. Ap’x. Shpg. Wgt. Reliance M/N Field Type XPY Tach Kit TENV TENV TENV DPG DPG DPG TENV D1815R D1802R CD1803R D1803R CDD1803R CD1805R CD2105R 6,040 6,040 9,906 6,040 6,040 7,266 14,534 N2 N2 N2 N2 N2 N2 N2 169 86 212 165 160 175 355 T18R1119 T18R1117 T18R1102 T18R1118 T18R1120 T18R1105 T21S1101 STR STR STR STR STR STR STR 413336-1R 413336-1R 413336-1R 413336-1R 413336-1R 413336-1R 413336-1R Arm. Field (a)(b) 7.2 9.5 14.1 14.8 14.8 24 23 0.721 0.72 1.21 0.946 0.946 1.67 1.3 NOTE: Encoder and tachometer kits on page 248. (a) Field amps at 25°C (b) Field amps for high voltage connection (c) 140TC C-face (d) 180TC C-face (e) Top mounted conduit box, if blower added, blower must be mounted F-1 or F-2. RPM III DC Shunt Wound SCR Drive Motors, 240V Armature 240V Field, Power Code C Inverter/Vector Motors & Controls DC Motors and Controls Soft Start & Dynamic Brakes 244 1.5 thru 5 Hp 3 thru 10 Hp NEMA 1811ATCZ thru 2113ATCZ Applications: Textile range drives, roofing machines, tube mills, and similar applications. Features: Range drive motors have matched IR drops within approximately 5 volts and good regulation characteristics out to the maximum field weakened speed of 2300 rpm. Capable of operation at 25% base speed with 67% armature current and motor field pre-weakened to 2100 rpm. Specially designed for use on multi-motor drives operating on a common voltage power supply such as textile range drives, roofing machines, tube mills, etc. F-1 mounting. Tach adaptable with thermostat. * Splash-Proof Guarded (SPG) is an open machine in which the ventilating openings are so constructed that successful operation is not interfered with when drops of liquid or solid particles strike or enter the enclosure at any angle not greater than 60 degrees downward from the vertical. Hp Base Speed NEMA Frame 3 5 7.5 10 1750/2300 1750/2300 1750/2300 1750/2300 C1811ATCZ (b) C1811ATCZ (b) C1812ATCZ (b) SC2113ATCZ (c) Voltage D.C. Arm. Field Arm. Field (a) 240 240 240 240 240 240 240 240 11 18.1 27 37 NOTE: Encoder and tachometer kits on page 248. (a) Field amps at 25°C (b) 180TC C-face (c) 210TC C-face Full Load Amperage 0.994 1.11 1.4 2.18 Enclosure * Catalog Number List Price Mult. Sym. Ap’x. Shpg. Wgt. Reliance M/N Field Type XPY Tach Kit SPG SPG SPG SPG CD2003R-2 CD2005R-2 CD2007R-2 D2010R-2 11,067 11,067 12,042 16,661 N2 N2 N2 N2 198 209 235 346 T18R1009 T18R1010 T18R1011 T21S1001 STAB STAB STAB STAB 413336-1R 413336-1R 413336-1R 417708-21 5 1750/2300 7.5 1750/2300 10 1750/2300 15 1750/2300 20 1750/2300 25 1750/2300 30 40 50 1750/2300 1750/2300 1750/2300 NEMA Frame C1812ATZ SC2113ATZ SC2113ATZ SC2113ATZ MC2113ATZ MC2113ATZ SC2512ATZ SC2512ATZ LC2512ATZ LC2512ATZ MC2812ATZ MC2812ATZ LC2812ATZ MC3212ATZ LC3212ATZ Voltage D.C. Arm. Field 240 500 240 500 240 500 240 500 240 500 240 500 500 500 500 150 150/300 150 150/300 150 150/300 150 150/300 150 150/300 150 150/300 150/300 150/300 150/300 Full Load Amperage Arm. Field (a)(b) 18.5 9 27 13.5 35.5 17.5 53.5 25.6 71 33 87 41 50 65 84 1.79 1.05 3.26 1.41 3.13 1.55 2.17 1.71 4.14 2.05 4.05 2.23 1.75 1.82 1.97 Catalog Number List Price Mult. Sym. Ap’x. Shpg. Wgt. Notes Reliance M/N Field Type XPY Tach Kit D2505R D5505R D2507R D5507R D2510R D5510R D2515R D5515R D2520R D5520R D2525R D5525R D5530R D5540R D5550R 13,081 15,311 17,059 17,059 18,820 18,820 28,213 28,213 30,464 30,464 43,228 43,228 48,066 65,449 69,186 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 251 340 359 360 379 405 560 547 640 640 805 815 895 1120 1270 87 87 87 87 87 87 6,87 87 87 87 87 86,87 87 87 87 T18R1005 (d) T21S201 (c) T21S301 T21S302 (d) T21S303 T21S304 T25S301 T25S302 T25S303 T25S304 T28S301 T28S302 T28S303 T32S301 T32S302 STAB STAB STAB STAB STAB STAB STAB STAB STAB STAB STAB STAB STAB STAB STAB 417709-17 417708.21 417709-65 417709-65 417709-65 417709-65 417709-66 417709-66 417709-66 417709-66 417709-67 417709-67 417709-67 417709-68 417709-68 Unit Handling Motors Features: Unique laminated square frame for improved commutation on rectified power supplies. The square configuration allows for increased rating per frame size. Class F rated insulation system. Service Line brushes with convenient wear indicating reference lines. PLS™ (Positive Lubrication System) for longer bearing and motor life. F-1 mounting unless otherwise specified. Tach adaptable with thermostat. Definite Purpose Motors Applications: Metals, paper, web processes, extruders, cranes, conveyors, packaging, printing, machine tools. Brake Motors Base/Max Speed NEMA 1812ATZ thru 3212ATZ 200 & 575 Volt Motors Hp 5 thru 50 Hp IEC Frame Motors RPM III DC Shunt Wound SCR Drive TEFC Motors, 240V & 500V Armature, Power Code C Farm Duty Motors DC Motors & Controls Inverter/Vector Motors & Controls DC Motors and Controls Soft Starters & Dynamic Brakes (a) Field amps at 25°C (b) Field amps for high voltage connection (c) TENV enclosure (d) Power Code D 50 Hertz Motors NOTE: Encoder and tachometer kits on page 248. 245 DC Motors & Controls Farm Duty Motors Definite Purpose Motors NEMA 2113ATZ thru 4414ATZ RPM III Wound Field SCR 10 thru 500 Hp Drive DPG-FV Motors, Applications: Metals, printing, extruders, cranes, conveyors, machine tools 240V & 500V Armature, Features: Laminated square frame for improved commutation. Tach Power Code C adaptable with thermostat. F1 mount unless otherwise specified. Unit Handling Motors Brake Motors Hp Base/Max Speed NEMA Frame 10 1750/2300 15 1750/2300 20 1750/2300 25 1750/2300 SC2113ATZ SC2113ATZ SC2113ATCZ SC2113ATZ SC2113ATZ SC2113ATZ SC2113ATZ MC2113ATZ MC2113ATZ MC2113ATZ LC2113ATZ LC2113ATZ LC2113ATZ SC2512ATZ LC2115ATZ LC2115ATZ MC2115ATZ MC2512ATZ LC2512ATZ LC2115ATZ LC2512ATZ C2514ATZ LC2512ATZ MC2812ATZ C2515ATZ C2514ATZ LC2812ATZ C2815ATZ C2515ATZ MC3212ATZ C2815ATZ C2813ATZ UC2813ATZ LC3212ATZ UC3214ATZ C2815ATZ C2815ATZ UC2815ATZ UC2815ATZ MC3612ATZ ULC3612ATZ UC3214ATZ LC3612ATZ C3613ATZ ULC3612ATZ C4011ATZ MC4013ATZ LC3613ATZ MC4013ATZ LC4013ATZ MC4013ATZ LC4013ATZ C4413ATZ C4412ATZ C4414ATZ 1750/2300 30 200 & 575 Volt Motors 40 1750/2300 1150/1800 1750/2300 1750/2100 1150/2000 50 1750/2100 1150/1900 IEC Frame Motors 60 1750/2100 1150/1900 75 50 Hertz Motors 100 1750/2100 1150/2000 1750/2000 1750/2100 1150/1850 1750/2000 125 1750/2000 1150/2000 Inverter/Vector Motors & Controls 1750/2000 150 1750/2100 1150/2000 200 1750/2100 DC Motors and Controls 1150/2000 250 300 Soft Start & Dynamic Brakes 400 500 1750/2100 1150/2000 1750/2000 1750/2100 1150/2000 1750/2000 1150/1600 1750/2050 1150/1450 Voltage D.C. Arm. Field Arm. Field (a) 500 240 240 500 500 240 500 500 240 500 500 240 500 500 500 240 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 300 150 150 300 300 150 300 300 150 300 300 150 300 300 300 150 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 18 56 56 27 27 76.5 37 37 96 46 43 109 52 51 54 146 69 68.5 72 87 84 87 102 100 102 124 124 125 167 162 168 204 204 203 204 245 245 245 245 240 249 322 321 323 405 400 406 478 478 485 643 635 644 797 805 NOTE: Encoder and tachometer kits on page 248. 246 Full Load Amperage 1.11 4.73 4.73 2.22 3.03 7.12 3.03 2.23 8.43 3.33 3.08 10 3.3 2.84 3.104 5.63 4.48 2.88 5.27 3.104 3.38 4.06 4.6 3.43 5.17 6.21 3.62 4.14 6.7 3.33 4.14 6.103 6.103 4.4 8.36 9.45 9.45 9.45 9.45 4.8 7.29 8.36 5.41 10.7 8.87 6.63 10.7 12.5 6.5 13.2 11.9 7.97 13 10.8 12.3 Catalog Number List Price Mult. Sym. Ap’x. Shpg. Wgt. Notes Reliance M/N Field Type XPY Tach Kit D5010RS-BV D2015R-BV CD2015R-BV D5015R-BV D5015RS-BV D2020R-BV D5020R-BV D5020RS-BV D2025R-BV D5025R-BV D5025RS-BV D2030R-BV D5030R-BV D5030RS-BV D5130R-BV D2040R-BV D5040R-BV D5040RS-BV D5140R-BV D5050R-BV D5050RS-BV D5150R-BV D5060R-BV D5060RS-BV D5160R-BV D5075R-BV D5075RS-BV D5175R-BV D50100R-BV D50100RS-BV D51100R-BV D50125R-BV D50125UR-BV D50125RS-BV D51125RR-BV D50150R-BV D50150RE-BV D50150UR-BV D50150URE-BV D50150RS-BV D51150RR-BV D50200RR-BV D50200RS-BV D51200R-BV D50250RR-BV D50250RS-BV D51250R-BV D50300R-BV D50300RS-BV D51300R-BV D50400R-BV D50400RS-BV D51400R-BV D50500R-BV D51500R-BV 19,133 16,556 17,153 16,556 19,133 16,556 16,556 20,894 18,317 18,317 22,483 19,905 19,905 30,609 26,587 26,587 23,683 31,738 29,962 26,587 32,860 34,634 29,962 45,623 39,995 34,634 50,462 56,918 39,995 67,915 56,918 49,873 51,108 71,773 73,535 56,918 56,918 58,152 58,152 88,976 89,964 73,535 91,619 106,410 89,964 124,469 145,465 113,818 150,442 163,196 145,465 168,174 201,741 196,381 206,180 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 345 (c) 345 (d) 345 (b) 375 345 (c) 345 (d) 390 370 (c) 370 (d) 410 472 (c) 400 445 535 (c) 480 480 501 570 (c) 640 520 660 (c) 695 610 860 (c) 805 767 885 (c) 1125 890 1210( c) 1239 997 945 1290 (c) 1475 1125 1125 1265 1255 1630 (c) 1850 1475 1905 (c) 1850 1891 2310 (c) 2735 2190 2815 (c) 3015 3040 3040 (c) 3830 3480 4560 101,102 103 103 103 101,102 103 103 101,102 103 6,104 101,102 103 103 101,102 104 6,103 103 6,101,102 104 103 6,101,102 6,104 103 6,101,102 6,103 103 6,101,102 6,103 103 6,101,102 6,104 6,103 5,6,103 6,101,102 5,6,103 6,103 6, 103 5,6,103 5,6,103 6,105 5,6,104 5,6,103 6,105 6,104 5,6,104 6,105 6,104 6,104 6,105 6,104 6,104 6,105 6,101,104 6,101,104 6,101,104 T21T1342 T21T1359 T21T1384 T21T1364 T21T1346 T21T1363 T21T1350 T21T1344 T21T1371 T21T1351 T21T1345 T21T1375 T21T1352 T25T1342 T21T1378 T21T1380 T21T2353 T25T1344 T25T1355 T21T2354 T25T1339 T25T1359 T25T2348 T28T1330 T25T1364 T25T2349 T28T1327 T28T1342 T25T2350 T32T1314 T28T1344 T28T1333 T28T1349 T32T1318 T32T1327 T28T1334 T28T1352 T28T1350 T28T1351 T36S1313 T36S1323 T32T1322 T36S1314 T36S1325 T36S1318 T40S1306 T40S1317 T36S1319 T40S1309 T40S1320 T40S1314 T40S1311 T44T1304 T44T1305 T44T1306 STAB STR STR STR STAB STR STR STAB STR STR STAB STR STR STAB STR STR STR STAB STR STR STAB STR STR STAB STR STR STAB STR STR STAB STR STR STR STAB STR STR STR STR STR STAB STR STR STAB STR STR STAB STR STR STAB STR STR STAB STR STR STR 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-26 417708-21 417708-21 417708-26 417708-26 417708-21 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-26 417708-156 417708-156 417708-156 (a) Field amps at 25°C (b) 210TC C-Face (c) Extruder duty enclosed commutator design (d) Power Code D 7.5 1750/2300 10 1750/2300 15 1750/2300 20 1750/2300 25 1750/2300 30 1750/2300 40 50 60 1750/2100 1750/2100 1750/2100 150 300 150 300 150 300 150 300 150 150/300 150 150/300 150 150/300 150 150/300 150/300 150/300 300 Arm. Field(a)(b) 11 5.2 19.2 9 28 13.5 37 17.4 56 27 74 35 91.5 43 111 52 68 85 100 List Price Mult. Sym. Ap’x. Shpg. Wgt. Notes Reliance M/N Field Type XPY Tach Kit D2003R D5003R D2005R D5005R D2007R D5007R D2010R D5010R D2015R D5015R D2020R D5020R D2025R D5025R D2030R D5030R D5040R D5050R D5060R 6,431 9,967 10,358 9,967 10,358 9,967 11,335 11,335 15,311 15,311 18,661 17,074 18,661 18,661 26,466 26,466 28,717 41,092 45,931 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 161 197 194 194 210 197 233 227 315 320 403 372 415 394 515 520 605 766 860 80,83 80 80,83 80 80,83 80 80,84 80,85 87 87 87 87 87 87 87 87 6,87 6,87 6,87 T18R1127 T18R1333 (d) T18R1318 (d) T18R1334 (d) T18R1301 (d) T18R1335 (d) T18R1302 (d) T18R1307 (d) T21S1330 T21S1322 T21S1331 T21S1323 T21S1332 T21S1324 T25S1330 T25S1322 T25S1323 T28S1313 T28S1314 STAB STR STAB STR STAB STR STAB STAB STAB STAB STAB STAB STAB STAB STAB STAB STAB STAB STAB 413336-1R 413336-1R 413336-1R 413336-1R 413336-1R 413336-1R 413336-1R 413336-1R 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-21 417708-26 417708-26 1.52 0.741 1.77 1 1.95 1.29 2.12 1.08 4.12 1.76 4.24 1.98 5.82 2.61 3.45 1.71 2.4 2.01 2.77 NOTE: Encoder and tachometer kits on page 248. (a) Field amps at 25°C (b) Field amps for high voltage connection (c) 180 TC C-face (e) Top mounted conduit box, if blower added, blower must be mounted F-1 or F-2 (d) Power Code D Definite Purpose Motors Unit Handling Motors Brake Motors 1750/2300 Field 240 500 240 500 240 500 240 500 240 500 240 500 240 500 240 500 500 500 500 Catalog Number 200 & 575 Volt Motors 5 Arm. Full Load Amperage IEC Frame Motors 1750/2300 DC189ATCZ (c)(e) C1811ATZ C1811ATZ C1811ATZ C1811ATZ C1811ATZ C1812ATZ C1812ATZ SC2113ATZ SC2113ATZ LC2113ATZ MC2113ATZ LC2113ATZ LC2113ATZ SC2512ATZ SC2512ATZ LC2512ATZ MC2812ATZ LC2812ATZ Voltage D.C. Features: Unique laminated square frame for improved commutation on rectified power supplies. The square configuration allows for increased rating per frame size. High limit thermostat. Provision for adding adapter mounted feedback device. Class F rated insulation system. Service Line brushes with convenient wear indicating reference lines. PLS™ (Positive Lubrication System) for longer bearing and motor life. F-1 mounting unless otherwise specified. 50 Hertz Motors 3 NEMA Frame Applications: Metals, paper, web processes, extruders, cranes, conveyors, packaging, printing, machine tools. Inverter/Vector Motors & Controls Base/Max Speed NEMA 189ATCZ thru 2812ATZ DC Motors and Controls Hp 3 thru 60 Hp Soft Starters & Dynamic Brakes RPM III Wound Field SCR Drive DPG Motors, 240V & 500V Armature Power Code C Farm Duty Motors DC Motors & Controls 247 DC Motors & Controls Farm Duty Motors RPM III DC Motor Applications: Encoder and Tachometer Kits for Field Installation Encoder and Tachometer Kits Features: Kits include the encoder or tachometer and all mounting hardware required for installation on RPM III DC Motors. Definite Purpose Motors Device Type Unit Handling Motors Brake Motors Catalog Number Frames Enclosure List Price Mult. Sym. Ap’x. Shpg. Wgt. 417708-30 417708-32 417708-33 417708-153 417708-34 417708-36 417708-37 417708-154 417708-133 417708-134 417708-135 417708-151 417708-126 417708-136 417708-137 417708-138 417708-25 417708-152 DC180, C180, DC2112 C210-C250 C280-C400 C440 DC180, C180, DC2112 C210-C250 C280-C400 C440 DC180, C180, DC2112 C210-C250 C280-C400 C440 DC180, C180, DC2112 C210-C250 C280-C400 C440 C280-C400 C440 DPG, DPFV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV DPG, DPFV, TENV DPG, DPFV, TENV 3,164 3,164 3,164 3,164 3,764 3,764 3,764 3,764 4,036 4,036 4,036 4,036 5,128 5,128 5,128 5,128 4,673 4,673 E8 E8 E8 E8 E8 E8 E8 E8 E8 E8 E8 E8 E8 E8 E8 E8 N5 N5 5 5 5 5 5 5 5 5 5 5 5 5 4 6 6 4 11 13 Output RD120-1 1 x 120 ppr RD120-2 2 x 120 ppr H20 1024 ppr RL67 1024z ppr RE045 45 VAC/ 1000 RPM 200 & 575 Volt Motors IEC Frame Motors 50 Hertz Motors Inverter/Vector Motors & Controls DC Motors and Controls Soft Start & Dynamic Brakes 248 Encoder and Tachometer Mounting Kits (less tach) Device Type XC42, XC46, BC42, BC46, H56, 800123-R & -S XPY, XPYII, 5PY, RPY444 RL67 Applications: Encoder and Tachometer mounting kits for field installation Features: Kits include all mounting hardware required for installation on RPM III DC motors. Feedback device not included. Catalog Number Frames Enclosure List Price Mult. Sym. Ap’x. Shpg. Wgt. 413336-2R 417708-22 417708-27 417708-155 417709-21 417709-58 417709-59 417709-60 417709-61 413336-1R 417708-21 417708-26 417708-156 417709-17 417709-65 417709-66 417709-67 417709-68 417708-40 417708-41 417708-42 417708-157 DC180, C180, DC2112 C210-C250 C280-C400 C440 C180 C210 C250 C280 C320 DC180, C180, DC2112 C210-C250 C280-C400 C440 C180 C210 C250 C280 C320 DC180, C180, DC2112 C210 - C250 C280 - C400 C440 DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV TEFC TEFC TEFC TEFC TEFC DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV TEFC TEFC TEFC TEFC TEFC DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV DPG, DPFV, TENV 1,689 1,689 1,689 1,689 4,245 4,245 4,245 4,245 4,245 1,689 1,689 1,689 1,689 4,245 4,245 4,245 4,245 4,245 1,091 1,091 1,091 1,091 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 9 9 9 9 19 20 23 23 29 7 7 7 8 6 6 9 15 18 1 2 1 1 C180ATZ, DC180ATZ C210ATZ C250ATZ C280ATZ C320ATZ C3612ATZ C3613ATZ C400ATZ C440ATZ 417077-51 419947-29 419947-30 419947-32 419947-34 417077-74 417077-127 417077-75 417077-126 1,491 1,491 1,491 1,823 2,123 2,123 2,123 2,324 4,738 A8 A8 A8 A8 A8 A8 A8 A8 A8 Ap’x. Shpg. Wgt. (lb) 44 52 39 55 81 55 75 85 225 Description Blower Kit Without Filter Blower Kit Without Filter Blower Kit Without Filter Blower Kit Without Filter Blower Kit Without Filter Blower Kit Without Filter Blower Kit Without Filter Blower Kit Without Filter Blower Kit Without Filter Filter Kits for use with DPG-FV, RPM III DC motors Catalog Number List Price Mult. Sym. C180ATZ, DC180ATZ C2113ATZ C2115ATZ C2512ATZ C2514ATZ C2515ATZ C2812ATZ C2813ATZ C2815ATZ C3210ATZ C3212ATZ C3214ATZ C3612ATZ C3613ATZ C400ATZ C440ATZ 417077-57 417077-58 417077-59 417077-58 417077-59 417077-59 417077-59 417077-59 417077-59 417077-59 417077-59 417077-59 417077-65 417077-102 417077-102 417077-124 911 911 911 911 911 911 911 911 911 911 911 911 1,165 1,642 1,642 1,893 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 Ap’x. Shpg. Wgt. (lb) 2 4 4 4 4 4 4 4 4 4 4 4 7 6 6 18 Description Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Washable Wire Mesh Canister Type Square Replaceable Polyester Type 50 Hertz Motors Motor Frame Definite Purpose Motors Mult. Sym. Unit Handling Motors List Price Brake Motors Catalog Number 200 & 575 Volt Motors Motor Frame IEC Frame Motors Blower Kits for use with RPM III DC Motors Suitable for operation on 230/460V or 240/480V, 3-Phase, 50/60 Hz Farm Duty Motors DC Motors & Controls Sliding Bases for RPM III DC motors List Price Mult. Sym. DC1810ATZ DC1811ATZ C1811ATZ C1812ATZ DC2112ATZ C2113ATZ C2115ATZ C2512ATZ C2514ATZ C2515ATZ UC2812ATZ UC2813ATZ UC2815ATZ UC3212ATZ UC3214ATZ UC3612ATZ UC3613ATZ 42384-26D 42384-26BE 42384-26BE 42384-26BF 42384-26BH 419914-1A 419914-1P 419914-1B 419914-1R 419914-1S 419914-1C 419914-1T 419914-1U 419914-1D 419914-1W 419914-1E 419914-1X 319 319 278 319 545 545 545 634 634 634 1,223 1,223 1,223 1,606 1,606 2,166 2,166 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 Ap’x. Shpg. Wgt. 14 17 17 17 29 50 36 33 59 36 37 26 42 69 76 76 81 Description Dimension Sheet Standard Duty Heavy Duty Heavy Duty Heavy Duty Heavy Duty Heavy Duty Heavy Duty Heavy Duty Heavy Duty Heavy Duty Heavy Duty Heavy Duty Heavy Duty Heavy Duty Heavy Duty Heavy Duty Heavy Duty 609987-501 609987-501 609987-1 609987-1 609958-51 609957-1 609957-1 609957-1 609957-1 609957-1 609957-1 609957-1 609957-1 609977-1 609977-1 609977-1 609977-1 DC Motors and Controls Catalog Number Soft Starters & Dynamic Brakes Motor Frame Inverter/Vector Motors & Controls Applications: Used for adjusting belt tension on belted applications. Not suitable for wall or ceiling mounting. 249 DC Motors & Controls Farm Duty Motors Definite Purpose Motors NEMA L186AT thru 506AT SCR Drive Motors Shunt 5 thru 250 Hp and Stabilized Shunt Applications: Conveyors, plastic extruders, packaging machinery and other Wound - DPFG, Self constant torque applications for DC SCR motors. Ventilated, Rigid Base Unit Handling Motors Features: Includes thermostat on interpole. Class F insulation system resistant to dirt, carbon, dust and moisture. High dielectric stability. Low moment of inertia armature for fast response. Constant pressure brush springs and longer brushes for reduced maintenance. Includes grease fittings and reliefs for bearing maintenance. Power code C and D or M-G sets. Maximum RPM by field weakening. Provisions for tach mounting. (See tach mounting kits on page 322). May be converted to blower ventilated (DPBV) for extended constant torque speed range. Brake Motors 200 & 575 Volt Motors IEC Frame Motors 50 Hertz Motors Base/Max Speed (a) NEMA Frame 5 1750/2300 L186AT 7 1/2 1750/2300 1810AT 218AT 10 1750/2300 219AT 15 1750/2300 258AT 20 1750/2300 259AT 25 1750/2300 288AT 287-8AT 30 1750/2300 288AT 40 50 60 75 100 125 150 200 250 1750/2100 1750/2100 1750/2100 1750/2100 1750/2000 1750/2000 1750/2000 1750/1900 1750/1900 328AT 328AT 365-6AT 366AT 368AT 407AT 409AT 504AT 506AT Hp Voltage D.C. Full Load Amperage Arm. Field Arm. 240 500 240 500 240 500 240 500 240 500 240 500 240 500 500 500 500 500 500 500 500 500 500 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 17.7 8.5 28.1 13.2 36.6 17.2 55 25.2 70.5 35.1 89.2 43.4 106 50 67.9 83.7 98.6 123 158 200 237 320 392 Field (b) .68 .6 .8 .69 2.16 1.17 2.58 1.4 2.48 1.24 2.99 1.64 4.52 2 2.17 2 1.75 1.48 3 3 3.7 3.9 5 Catalog Number List Price Motors Only (c) Mult. Sym. Ap’x. Shpg. Wgt. (d) XPY Tach Kit Blower Catalog Number Notes (e) D2005P D5005P D2007P D5007P D2010P D5010P D2015P D5015P D2020P D5020P D2025P D5025P D2030P D5030P D5040P D5050P D5060P D5075P D50100P D50125P D50150P D50200P D50250P 6,242 6,242 7,258 8,009 8,238 8,238 9,861 9,861 11,273 11,273 15,236 15,236 15,236 15,236 20,393 20,393 27,343 27,343 36,878 42,414 52,882 65,981 79,067 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 180 162 218 235 245 255 250 250 250 250 575 490 595 590 784 835 790 905 1100 1445 1785 2095 2540 TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP400XP TKP400XP TKP500XP TKP500XP FVB3180 FVB3180 FVB3180 FVB3210 FVB3210 FVB3210 FVB3250 FVB3250 FVB3250 FVB3250 FVB4280 FVB4280 FVB4280 FVB4280 FVB6320 FVB6320 FVB6400 FVB6400 FVB6400 FVB6400 FVB6400 FVB8500 FVB8500 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 Inverter/Vector Motors & Controls NOTES: (a) DPFG enclosure is self-ventilated. Speed can be reduced to approximately 60% of base speed with constant torque. See performance data in CA608 catalog for specific speed-torque curves. Separate blower can be used to increase operating range below 60% of base speed. (b) Field amps are for 150V connection on 240VDC motors; 300V connection on 500VDC motors. 360, 400 & 500 frames are 4 pole stabilized shunt until 3rd quarter 2006 when they became shunt. Others are 2 pole shunt. (c) Does not include price of blower. See page 253 for pricing. (d) Does not include weight of blower. See page 253 for weights. (e) See notes on inside back flap. 180 frame motors are supplied without external conduit box, see online layout drawing for details. DC Motors and Controls Soft Start & Dynamic Brakes 250 50 1750/2100 328AT 60 1750/2100 366AT 365-6AT 75 1750/2100 366AT 100 125 150 200 250 300 400 500 1750/2000 1750/2000 1750/2000 1750/1900 1750/1900 1750 1750/1900 1750/1900 368AT 368AT 407-9AT 409AT 504-6AT 506AT 508AT 5010AT Field Arm. Field (a) 240 500 240 500 240 500 240 500 500 500 500 500 500 500 500 500 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 138 67.9 175 83.7 201 98.6 256 123 158 197 238 311 405 478 624 788 2.64 2.17 2.64 2 5.6 1.75 5.6 1.48 3 3 2.7 3.75 4.9 6.2 6.08 6 D2040P-BV D5040P-BV D2050P-BV D5050P-BV D2060P-BV D5060P-BV D2075P-BV D5075P-BV D50100P-BV D50125P-BV D50150P-BV D50200P-BV D50250P-BV D50300P-BV D50400P-BV D50500P-BV List Price w/Blower & Filter Mult. Sym. Ap’x. Shpg. Wgt. XPY Tach Kit Notes (b) 23,764 23,764 23,764 23,764 30,715 30,715 30,715 30,715 40,250 40,250 46,126 57,457 70,339 83,425 117,765 154,655 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 855 830 835 885 980 880 975 960 1145 1170 1515 1830 2175 2640 3285 4170 TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP400XP TKP400XP TKP500XP TKP500XP TKP5006XP TKP500XP 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 NOTE: (a) Field amps are for 150V connection on 240VDC motors; 300V connection on 500VDC motors. 360 through 500 frames are 4 pole stabilized shunt, until 3rd quarter 2006 when they became shunt. Others are 2 pole shunt. Tach mounting kits on page 253. (b) See notes on inside back flap. SCR Drive Motor 240V Armature - 240V Field Shunt Wound DPFG Self-Ventilated Rigid Base and C-Face Hp 3 5 7 1/2 10 15 Base/Max Speed 1750/2300 1750/2300 1750/2300 1750/2300 1750/2300 NEMA Frame L186ATC L186ATC 1810ATC 219ATC 258ATC Voltage D.C. 3 thru 15 Hp NEMA L186ATC thru 258ATC Definite Purpose Motors Unit Handling Motors Brake Motors 328AT Arm. Catalog Number 200 & 575 Volt Motors 1750/2100 Full Load Amperage Applications: Conveyors, plastic extruders, packaging machinery and other constant torque applications for DC SCR motors. Features: Includes thermostat on interpole. Class F insulation system resistant to dirt, carbon, dust and moisture. High dielectric stability. Low moment of inertia armature for fast response. Constant pressure brush springs and longer brushes for reduced maintenance. Includes grease fittings and reliefs for bearing maintenance. Power code C or M-G sets. Maximum RPM by field weakening. Full Load Amperage Arm. Field Arm. 240 240 240 240 240 120/240 120/240 120/240 120/240 120/240 10.6 17.7 28.1 36.6 55 Field (a) .45 .45 .52 1.26 1.26 Catalog Number List Price Motor Mult. Sym. Ap’x. Shpg. Wgt. (c) XPY Tach Kit Blower Catalog Number Notes (d) 6,453 6,453 7,468 8,834 10,458 N2 N2 N2 N2 N2 170 170 222 250 250 TKP1836XP TKP1836XP TKP1836XP TKP1836XP TKP1836XP FVB3180 FVB3180 FVB3180 FVB3210 FVB3250 1, 3 1, 3 1, 3 1, 3 1, 3 (b) CD2003P-2 CD2005P-2 CD2007P-2 CD2010P-2 CD2015P-2 NOTE: (a) Field amps for 240VDC connection. (b) Does not include price of blower and filter. See page 253 for pricing. (c) Does not include weight of blower and filter. See page 253 for weights. Tach mounting kits on page 253. (d) See notes on inside back flap. 180 frame motors are supplied without external conduit box, see online layout drawing for details. Inverter/Vector Motors & Controls 40 Voltage D.C. DC Motors and Controls NEMA Frame Soft Starters & Dynamic Brakes Base/Max Speed Hp IEC Frame Motors Features: Includes thermostat on interpole. Class F insulation system resistant to dirt, carton, dust and moisture. High dielectric stability. Low moment of inertia armature for fast response. Constant pressure brush springs and longer brushes for reduced maintenance. Includes grease fittings and reliefs for bearing maintenance. Power code C or M-G sets. Maximum RPM by field weakening. Provisions for tach mounting. (See tach kits on page 322). Blower-ventilated, includes filter. 50 Hertz Motors NEMA 328AT thru 5010AT SCR Drive Motor Shunt 40 thru 500 Hp and Stabilized Shunt Applications: Conveyors, plastic extruders, packaging machinery and other Wound DPBV Enclosure constant torque applications for DC SCR motors. - Rigid Base Farm Duty Motors DC Motors & Controls 251 DC Motors & Controls Farm Duty Motors Shunt Wound SCR Drive Motor - TEFC, Rigid Base 5 thru 25 Hp NEMA 1810AT THRU 328AT Applications: Conveyors and packaging machinery. Definite Purpose Motors Features: Includes thermostat on interpole, grease fittings and reliefs. Class F insulation system. Constant pressure brush springs and precision brush holders. Provisions for tach mounting ( See tach mounting kits page 322). Unit Handling Motors Brake Motors 200 & 575 Volt Motors Base/Max Speed NEMA Frame 5 1750/2300 1810AT 7 1/2 1750/2300 2110AT 10 1750/2300 259AT 15 1750/2300 288AT 20 1750/2300 328AT 25 1750/2300 328AT Hp Voltage D.C. Full Load Amperage Arm. Field Arm. Field (a) 240 500 240 500 240 500 240 500 240 500 240 500 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 150/300 17.6 8.3 26.6 12.3 34.3 16.3 51.7 24.5 68.8 32.7 84.8 40.9 0.68 0.34 2.10 1.05 1.72 0.86 1.96 0.99 2.22 1.11 2.22 1.11 Catalog Number List Price Motors Only Mult. Sym. Ap’x. Shpg. Wgt. XPY Tach Kit Notes (b) 9,004 9,004 10,480 10,480 13,020 13,020 17,374 17,374 22,882 22,882 22,882 22,882 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 220 214 300 310 250 250 630 630 850 875 872 870 N/A N/A TKP2136XPT TKP2136XPT TKP2136XPT TKP2136XPT TKP2136XPT TKP2136XPT TKP2136XPT TKP2136XPT TKP2136XPT TKP2136XPT 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 D2505P D5505P D2507P D5507P D2510P D5510P D2515P D5515P D2520P D5520P D2525P D5525P NOTE: (a) Field amps are for 150V connection on 240VDC motors; 300V connection on 500VDC motors. Tach mounting kits on page 253. (b) See notes on inside back flap. 180 frame motors are supplied without external conduit box, see online layout drawing for details. IEC Frame Motors 5 thru 40 kW Lifting Magnet Generators Applications: Crane mounted lifting magnets for recyclers and steel mills. Features: Heavy duty steel frame. Cast iron endplates. Class H insulation with Class F temperature rise. Precision brush holders. Constant force brush springs. Double sealed ball bearings. Compound wound with drooping voltage characteristics. DPFG enclosure. Weather resistant paint. F-2 conduit box. CDMG generators have C-face and base mounting for hydraulic pump or PTO mounting. 50 Hertz Motors Inverter/Vector Motors & Controls DC Motors and Controls Soft Start & Dynamic Brakes 252 NEMA 1810AT thru 329AT kW Base Speed 5 7 1/2 2500 2500 10 2500 15 1750 20 1750 25 1750 33 1750 40 1750 Voltage D.C. NEMA Frame 1810AT 219AT 219AT 219ATC 259AT 259ATC 288AT 288ATC 328AT 328ATC 328AT 328ATC 329AT Full Load Amperage Arm. Field Arm. Field 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 21.7 32.6 43.5 43.5 65 65 87 87 109 109 144 144 174 0.61 1.14 0.72 0.72 1.3 1.3 1.8 1.8 2.13 2.13 2.13 2.13 3.7 Field Control Rheostat Catalog Number List Price Mult. Sym. Ap’x. Shpg. Wgt. Ohms Amp Max. DMG2305 DMG2307 DMG2310 CDMG2310 DMG2315 CDMG2315 DMG2320 CDMG2320 DMG2325 CDMG2325 DMG2333 CDMG2333 DMG2340 7,521 8,652 9,589 10,190 16,097 16,684 17,622 18,625 19,269 20,265 24,435 25,423 26,785 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 220 245 250 250 250 250 595 620 820 886 840 880 910 300 150 200 200 200 200 125 125 100 100 100 100 50 0.85 1.6 1.4 1.4 1.82 1.82 2.52 2.52 3.0 3.0 3.0 3.0 5.2 NOTE: Field control rheostat and meters are not included in price or available from Baldor. (a) See notes on inside back flap. Notes (a) 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 1, 3 Tach Mounting Kits for DC Integral Hp Motor Catalog No. Ending With “P” Tach Type Motor Frame Motor Enclosure Catalog Number List Price Mult. Sym. XPYII XPY, DPY BTG1000 180/360 210/360 400 500 210/360 500 180/360 400 500 210/360 400 500 210/360 400 500 DPFG, DPBV TEFC DPFG, DPBV DPFG, DPBV DPFG, DPBV DPFG, DPBV DPFG, DPBV DPFG, DPBV DPFG, DPBV DPFG, DPBV DPFG, DPBV DPFG, DPBV DPFG, DPBV DPFG, DPBV DPFG, DPBV TKP1836XP TKP2136XPT TKP400XP TKP500XP TKP2136XC TKP500XC TKP1836ENC TKP400ENC TKP500ENC TKP2136NC TKP400NC TKP500NC TKP2136AC TKP400AC TKP500AC 1,142 1,142 1,142 1,142 1,689 1,689 867 867 867 65 65 65 65 65 65 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 A8 XC42 or XC46 ENC00NV ENCODER NCS PANCAKE IEC Frame Motors AC PANCAKE Ap’x. Shpg. Wgt. 1 13 3 3 16 7 17 16 17 3 1 1 2 1 1 Unit Handling Motors Features: Tach mounting kits supply adapter, coupling, accessory shaft and mounting hardware. Allows mounting to 8.5 inch accessory face on most large DC motors. Brake Motors Applications: Allows addition of DC, AC and digital tachometers to large DC motors for closed-loop operation. 200 & 575 Volt Motors Tach Mounting Kits and Cooling Blowers for DC Integral Hp Motors Definite Purpose Motors Farm Duty Motors DC Motors & Controls 180 210 250 280 320 360-400 504-506 508-5012 FVB3180 FVB3210 FVB3250 FVB4280 FVB6320 FVB6400 FVB8500 FVB95010 (a) 180, 210, 250 280 320,360,400 504-506 FLT3210-250 (b) FLT4280 FLT6320-400 FLT8500 Blower Power Blower Size Blower and Mounting Kit 1 PH LM 3 3 PH LM 3 3 PH LM 3 3 PH LM 4 3 PH LM 6 3 PH LM 6 3 PH LM 8 3 PH LM 9 Filter and Hardware for Above Blowers LM 3 LM 4 LM 6 LM 8 List Price Mult. Sym. Ap’x. Shpg. Wgt. 1,491 1,491 1,491 1,823 2,123 2,323 2,750 4,738 A8 A8 A8 A8 A8 A8 A8 A8 18 25 19 44 46 59 93 171 791 791 791 965 A8 A8 A8 A8 2 9 14 9 Inverter/Vector Motors & Controls Catalog Number DC Motors and Controls Motor Frame 50 Hertz Motors Blower and Mounting Kits for DC Integral Hp Motor Catalog No. Ending With “P” Soft Starters & Dynamic Brakes NOTE: (a) Includes Blower and Filter. (b) Also used with FVB3180. 253 DC Motors & Controls Farm Duty Motors Tach Generators DC, AC and Digital Output Applications: Speed feedback for controls (encoders also offer position feedback). Features: Ball bearing construction, standard mounting flanges and/or feet. Definite Purpose Motors Unit Handling Motors Brake Motors 200 & 575 Volt Motors IEC Frame Motors 50 Hertz Motors Inverter/Vector Motors & Controls DC Motors and Controls Soft Start & Dynamic Brakes 254 Generator Type Voltage 30AFL-O XPYIII XPYII XPYII XPY XPYIII XPY XPYII XPY 50VDC 100VDC 100VDC 100VDC 50VDC 50VDC 50VDC XPYII XPYIII XPYII XPYII XPYIII DPY DPY E-ACC E-ACC XPY XPY XPYII XPYII XPY XPYIII XPY XPY XC42 XPY XC42 XC46 XC42 XC46 XC42 XC46 AC XC46 NCS AC NCS 100VDC 100VDC 50VDC 50VDC 1024PPR 1024PPR 1024PPR 1024PPR 60VDC 60VDC 60VDC 100VDC 60VDC 50VDC 100VDC 100VDC 50VDC 50VDC 100VDC 50VDC 100VDC 45/90VAC 50VDC 50VDC 45/90VAC 50VDC Catalog Number List Price XPY Flange Mount (DC) BTG1000 409 559 BTG100XPS 1,021 743 PTG100XPS 1,509 1099 PTG100XP 1,453 1058 BTG50XPS 1,021 743 PTG50XPS 1,509 1099 PTG50XP 1,453 1058 XPY Washdown Flange Mount (DC) PTGWD100XPS 1,607 1170 BTGWD100XPS 1,214 884 PTGWD50XPS 1,607 1170 Encoder BTGWD50XPS Based Digital PY Flange Mount 1,214 Encoder PTG1024LD Based (a) Digital PY Flange Mount 1380 PTG1024LD Electrically (a) Isolated Encoder1,895 ENC00NV (a) (b) Isolated Encoder1501 Electrically (a) (b) Metric Flange Mount (DC) 1,932 ENC00NV Metric (c) Flange Mount (DC) 1058 PTG60XP-M PTG60XP-M (c) (c) 1,453 1099 PTG60XPS-M PTG60XPS-M Foot (c) Mount (DC) 1,509 PFTG100XP (c) 1058 1,021 BTG60XPS-M PFTG50XP 1058 Foot Mount (DC) Foot Mount with Face (DC) 1,453 PFTG100XP PFTG42100X 2081 PFTG50XP 1,453 PFTG4250XC Foot Mount with Face (DC) 2127 PFTG46100X 3659 PFTG42100X 2,857 PFTG4650XC 3659 PFTG4250XC 2,920 Pancake Mount (AC & DC) 5,021 PFTG46100X PTG4590AC (d) ** 1017 PFTG4650XC 5,021 PTG50NC Pancake (d) **Mount (AC & DC) 1518 PTG4590AC (d) ** 1,396 PTG50NC (d) ** 2,085 Mult. Sym. Ap’x. Shpg. Wgt. DS N5 N5 N5 N5 N5 N5 7 2 10 36 23 8 36 N5 N5 N5 N5 N5 N5 E8 E8 N5 N5 N5 N5 N5 N5 N5 N5 N5 N5 N5 N5 N5 N5 N5 9 2 10 2 1 1 2 2 8 5 8 62 6 6 33 6 32 43 33 44 32 43 9 44 8 8 8 NOTE: Flange mounted tachs require tach adapters shown on pages 253 & 255. XPY tachs have UL listing, file number E109527, CSA file number LR36841-5, XPYII tachs are pending approval. (a) See page 196 for cables. (b) Electrically isolated encoder & kit: Mounts to SCR motors using appropriate adapter shown on page 253 may eliminate the need for EXB00801 isolated encoder feedback board. (c) Requires adapter for metric flange tach. Will not mount on adapters for PY flanges. (d) Does not mount to TEFC. See catalog MN605 for details. Will only mount to DPFG and DPBV motors on pages 250 & 251 using adapters shown on page 253. 3300P TK3300 202 A8 1 3400D/P TK3400 358 A8 4 3500D/P TK3500 377 A8 9 3600D TK3600 498 A8 5 3600P TK3600PM 498 A8 3 7500D TK7500 516 A8 17 9100D TK9100 557 A8 23 Definite Purpose Motors Unit Handling Motors Ap’x. Shpg. Wgt. Brake Motors Mult. Sym. 200 & 575 Volt Motors List Price IEC Frame Motors Kit Catalog Number 50 Hertz Motors Baldor Motor Type Inverter/Vector Motors & Controls Complete kits consisting of fan cover (except TK3300), shaft extension coupling and tach adapter bracket with miscellaneous hardware. If you prefer, the conversion can be made by Baldor Mod Express. Tach kits will not work with Explosion Proof Motors (CDPX or CDX). See PY flange mount tachs shown on page 254. DC Motors and Controls For PY Flange mounted BTG1000, XPY, XPYII and DPY tachometers Soft Starters & Dynamic Brakes Field Conversion Tach Mounting Kits for Permanent Magnet and Shunt Wound Motor Farm Duty Motors DC Motors & Controls 255 DC Motors & Controls Farm Duty Motors Fractional Horsepower DC Speed Controls for PMDC Motors 1/15 thru 1/4 Definite Purpose Motors Applications: Conveyors, machine tools and other applications requiring adjustable speed. Features: Simple DC motor control with built-in circuit breaker, center lock reversing switch (center off), on/off switch, 7 foot SJO oil resistant cord, and variable voltage transformer for manual speed adjustment. NEMA 1 enclosure is standard. CSA list file # LR54532. Unit Handling Motors Max Hp 1/15 1/8 1/4 Catalog Number BC110 BC115 BC130 List Price 549 586 746 Brake Motors 200 & 575 Volt Motors NEMA 1 Enclosed DC Controls for PMDC and Shunt Wound Motors IEC Frame Motors BC140 ENCLOSED (NEMA 1) 50 Hertz Motors NOTE: Inverter/Vector Motors & Controls DC Motors and Controls Soft Start & Dynamic Brakes 256 115 VAC Single Phase 50/60 Hz. Mult Sym. E9 E9 E9 1/100 thru 2 Hp Ap’x Shpg. Wgt. 5 6 10 Amp Capacity 1.0 1.5 3.0 Input Voltage 115VAC 115VAC 115VAC 115/230 VAC Single Phase 50/60 Hz. Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Features: SCR controls have a free-wheeling diode and feature adjustable accel, decel, current limit, IR comp, min. and max speed pots to match applications. The anti-demag feature protects PM motors and helps protect the SCR power bridge against direct shorts. The controls have US and Canadian UL component recognition. A Plug-in Horsepower Resistor® and armature fuse must be ordered and installed in BC138, BC139, BC140, BC140-FBR, BC141 and BC142. Hp Range Catalog Number List Price Mult. Sym. 1/100-1/3 1/50-3/4 1/100-2 (a) 1/100-2 (a) BC138 BC139 BC140 BC140-FBR 218 218 369 510 E9 E9 E9 E9 Ap’x Shpg. Wgt. Lbs. 1 1 3 3 Input Voltage 115 230 115/230 115/230 (a) 1 Hp at 115V and 2 Hp at 230V requires BC143 heatsink kit. See page 330 for features. FBR=Forward/Brake/Reverse. DC Control Accessories Catalog Number Description List Price Mult. Sym. BC24-LF BC143 BC144 BC145 BC146 BC147 BC148 BC149 BC152 BC218 Ac Line Filter for use with CE Applications External Heatsink Kit (BC140, BC140-FBR, BC141, BC142, BC204) Forward-Brake-Reverse Switch Kit for BC140 Signal Isolator Board Current Sensing Relay/Overload Protector Barrier Terminal Board (BC141 and BC142) Replacement Potentiometer Kit (5K ohm) Knob and Dial Kit Barrier Terminal Board With Signal Isolator (BC141 and BC142) DIN-rail mounting kit for BC141, BC142 or BC204 75 72 124 211 136 30 13 15 193 36 E9 E9 E9 E9 E9 E9 E9 E9 E9 E9 Ap’x. Shpg. Wgt. 1 2 1 1 1 1 1 1 1 1 NOTE: BC24-LF is an AC line filter required for applications where CE is required if the control is not filtered elsewhere in the application. This filter may be used on most 115 or 230 VAC, single phase applications where CE is required. Features: Chassis-mount SCR controls have a free-wheeling diode and feature adjustable accel, decel, current limit, IR comp, min and max speed pots to match applications. The anti-demag feature protects PM motors and helps protect the SCR power bride against direct shorts. The controls have US and Canadian UL component recognition. List Price Mult. Sym. Standard Model, single voltage BC141 with BC152 Signal Isolator and BC143 Heatsink factory installed Standard Model, single voltage BC142 with BC152 Signal Isolator and BC143 Heatsink factory installed 202 E9 Ap’x. Shpg. Wgt. 1 477 E9 2 115 202 E9 2 230 499 E9 2 230 BC142-5 Dual voltage, without fuse holders 225 E9 1 115/230 BC142-6 Standard Model, dual voltage 224 E9 1 115/230 499 E9 1 115/230 660 E9 5 230 BC141 1/100-1 1/2 BC141-SIH 1/100-3 (a) BC142 1/100 - 3 BC142-SIH (a) 1/100-1 1/2 1/50-3 1/100 - 1 1/2 (a) 1/50 - 3 1/100 - 1 1/2 1/50 - 3 5 BC142-6SIH BC155 BC142-6 with BC152 signal isolator board and BC143 heatsink factory installed 230V - 5 Hp Input Voltage 115 Plug-in Horsepower Resistor and Fuse Kit Motor Hp Armature Voltage 90-130V 1/100 1/50 1/30 1/20 1/15 1/12 1/8 1/6 1/4 1/3 1/2 3/4 1 (a) 1 1/2 (a) 180V 1/50 1/25 1/15 1/10 1/8 1/6 1/4 1/3 1/2 3/4 1 1 1/2 2 (a) 3 (a) IEC Frame Motors NOTE: Above controls include 5k speed potentiometer. (a) 1-1.5 Hp at 115 Volts and 2-3 Hp at 230 Volts, requires BC143 Heatsink kit. BC155 Includes integral heatsink. Please refer to page 330 for features. Brake Motors 1/100-1 1/2 (a) Description Input Voltage / Max. Hp A Plug-in Horsepower Resistor® and armature fuse must be ordered and installed in BC138, BC139, BC140, BC140-FBR, BC141 and BC142. These should be selected based on the motor’s rated current. The price of the Hp resistor and fuse is included in the BC138, BC139, BC140, BC140-FBR, BC141 and BC142 list price. See selection below for catalog number. Spare resistor kits are available for $11.00 list, E9 multiplier. Plug-In Hp Resistor Resistance Value (Ohms) Catalog Number Ap’x DC Current (Amps) DC Fuse Rating For Armature 1.0 0.51 0.35 0.25 0.25 0.18 0.1 0.1 0.05 0.035 0.025 0.015 0.01 0.006 BR1000 BR0510 BR0350 BR0250 BR0251 BR0180 BR0100 BR0101 BR0050 BR0035 BR0025 BR0015SP BR0010SP BR0006 0.20 0.30 0.33 0.5 0.8 0.85 1.3 2.0 2.5 3.3 5.0 7.5 10 15 0.5 0.5 0.5 0.75 1.0 1.25 2.0 2.5 4.0 5.0 8.0 12.0 15.0 25.0 (b) NOTE: (a) External Heatsink required. (b) Also used with AC Line Fuse. For AC line fuse rating see manual. 50 Hertz Motors Catalog Number Inverter/Vector Motors & Controls Hp Range DC Motors and Controls BC141 / BC142 Definite Purpose Motors Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Unit Handling Motors 115 VAC Single Phase 50/60 Hz. 230 VAC Single Phase 50/60 Hz. 200 & 575 Volt Motors 1/100 thru 1.5 Hp 1/50 thru 5 Hp Soft Starters & Dynamic Brakes Chassis Mount DC Controls Farm Duty Motors DC Motors & Controls 257 DC Motors & Controls Farm Duty Motors NEMA 4X DC Control and Accessories 1/4 thru 2 Hp 3 Hp 115/230 VAC 230 VAC Single Phase 50/60 Hz. Single Phase 50/60 Hz. Definite Purpose Motors Applications: Constant torque, new or replacement. Unit Handling Motors Features: BC154, BCWD140 and BC160 are non-regen controls with reversal by means of switching the armature leads (BCWD140 has a forward/brake/ reverse switch mounted). BC254 is a line regenerative SCR control that can drive the motor to a timed stop. BC354 is a PWM control that provides lowripple DC power to the motor allowing more Hp when used with a 130 or 260 VDC motor. All offer a choice of armature or tachometer feedback and a speed or torque mode. No Hp resistors are needed for these controls, current is jumper selectable. BC154, BC160, BC254 and BC354 are painted black and come with a start-stop switch. BCWD140 comes with white epoxy paint and also forward/ brake/reverse and run-jog switches. See page 330 for features. Brake Motors 200 & 575 Volt Motors Hp Range Catalog Number 1/4-2 BC154 BC154-P BC154-R BC154-SI IEC Frame Motors 3 BC160 1/4-2 BCWD140 1/8-2 BC254 BC254-FBR 1/4-2 BC354 Description Input Voltage / Max. Hp List Price NEMA 4X SCR (black) Standard model - 120V - 1 Hp, 230V - 2 Hp 467 BC154 with POWER SWITCH instead of START/STOP SW. 467 BC154 with BC156 - FBR Switch factory installed 616 BC154 with BC145 Signal Isolator Board and BC158 751 Auto/Man Switch kit factory installed 120V - 1.5 Hp, 230V - 3 Hp 537 NEMA 4X Washdown Duty SCR (white) 120V - 1 Hp, 230V - 2 Hp 625 NEMA 4X Washdown Duty Line Regen SCR (black) 673 120V - 1 Hp, 230V - 2 Hp (a) 706 BC254 with BC253 FWD-BRAKE-REV switch factory installed NEMA 4X Washdown Duty PWM DC (black) (b) 120V - 1 Hp, 230V - 2 Hp 723 Mult. Sym. Ap’x. Shpg. Wgt. Input Voltage E9 E9 E9 5 5 5 115/230 115/230 115/230 E9 5 115/230 E9 3 115/230 E9 6 115/230 E9 E9 5 5 115/230 115/230 E9 5 115/230 NOTE: (a) See page 329 for BC254 accessories. (b) Output current is 7.5 amps; Output voltage is 130VDC for 115VAC input - 260VDC for 230VAC input. Motors designed for these voltages will give the best performance. 50 Hertz Motors Inverter/Vector Motors & Controls DC SCR NEMA 4X DC Control Accessories Catalog Number DC Motors and Controls BC153 BC156 BC157 BC158 BC159 BC145 Description Electronic Forward-Dynamic Brake-Reverse Kit for BC154, BC354 Mechanical Forward-Dynamic Brake-Reverse Switch for BC154, BC354 Run/Jog switch for BC154 & BC160, BC354 Auto/Manual Installation Kit for BC145 signal isolator for BC154, BC160, BC354 AC Line Switch Kit for BC154, BCWD140, BC254, BC354 Signal Isolator Board List Price Mult. Sym. 223 145 27 60 32 211 E9 E9 E9 E9 E9 E9 NOTE: BC159 AC Line Switch Kit is factory installed on BC154, BCWD140, BC354. Listed here as replacement or spare parts. Soft Start & Dynamic Brakes 258 Ap’x. Shpg. Wgt. 1 1 1 1 1 1 Applications: Frequent start/stop/reverse applications or where controlled braking is required. Features: Single phase line regenerative open chassis control to operate permanent magnet or wound field DC motors. These line regen controls are ideal for applications with overhauling loads. In torque mode, it can be used for tensioning applications. Several accessory boards are available to further customize the control. Includes 5k speed potentiometer. Jumper selectable current settings. Hp Range Catalog Number BC204 1/8-2 (a) BC204-BPSI 1/4-2 1/4-3 5 BC200 BC201 BC203 BC254 1/8-2 BC254-FBR Description Input Voltage / Max. Hp List Price Line Regen SCR 120V 1 Hp, 230V 2 Hp, Standard Model 377 BC204 with BC215 Bi-polar Signal Isolator 487 factory installed 120V 1 Hp, 230V 2 Hp 704 120V 1-1/2 Hp, 230V 3 Hp 836 230V 5Hp 1,052 NEMA 4X Washdown Duty Line Regen SCR 120V - 1Hp, 230V - 2Hp Standard Model 673 BC254 with Power On/Off switch instead of Start/ Stop switch, and BC253. Forward-Brake-Reverse 706 switch factory installed Mult. Sym. Ap’x. Shpg. Wgt. E9 3 E9 3 E9 E9 E9 4 1 10 115/230 115/230 230 E9 5 115/230 E9 5 115/230 List Price Mult. Sym. Ap’x. Shpg. Wgt. 216 E9 1 72 100 77 36 E9 E9 E9 E9 2 3 1 1 213 27 60 27 E9 E9 E9 E9 1 1 1 5 Definite Purpose Motors Single Phase 50/60 Hz. Single Phase 50/60 Hz. Unit Handling Motors 115/230 VAC 230 VAC Input Voltage 115/230 Brake Motors 1/4 thru 3 Hp 5 Hp 200 & 575 Volt Motors Line Regenerative DC Controls and Accessories Farm Duty Motors DC Motors & Controls IEC Frame Motors NOTE: (a) 1 Hp at 115 volts and 2 Hp at 230 volts requires BC143 heatsink kit. Catalog Number Description Accessories for BC200, BC201 and BC203 BC212 Bipolar signal isolator board 50 Hertz Motors Line Regenerative DC Control Accessories BC245 BC253 BC258 BC259 Bipolar signal isolator for BC254 Forward-Stop-Brake-Reverse Switch for BC254 Auto-manual Switch for BC254 AC Line Switch for BC254 Accessories for BC254 DC Motors and Controls External Heatsink Kit Bipolar signal isolator board Multispeed board for BC204 DIN rail mounting kit Soft Starters & Dynamic Brakes BC143 BC215 BC216 BC218 Inverter/Vector Motors & Controls Accessories for BC204 259 DC Motors & Controls Farm Duty Motors NEMA Enclosed DC Control Specifications Features Definite Purpose Motors Unit Handling Motors Brake Motors 200 & 575 Volt Motors IEC Frame Motors 50 Hertz Motors Inverter/Vector Motors & Controls DC Motors and Controls Soft Start & Dynamic Brakes 260 Catalog Number BC140 or BC154 BC140-FBR BC138 BC139 Enclosure NEMA 1 NEMA 1 NEMA 1 NEMA 4X NEMA 4X Control Type AC Line Input DC Armature Voltage Nominal Shunt Field Power Supply Voltage - DC Rated Horsepower Range External Heat Sink (BC143) Required Speed Range (Motor May Be 20: 1 Constant Torque) Adjustable Acceleration Time Adjustable Deceleration Time Minimum Speed Adjustable Maximum Speed Adjustable Current Limit Adjustable Adjustable Current Limit and Trip Out Type NEMA K 115 90 NEMA K 230 180 NEMA K 115 230 90 180 NEMA K 115 230 90 180 NEMA K 230 180 50/100 100/200 50/100 100/200 50/100 100/200 100/200 50/100 1/100 - 1/3 1/50-3/4 1/100-1 1/50-2 No 3 Not Required 1/50-1 No 1/50-1 1/25-2 Not Required 50:1 50:1 50:1 50:1 50:1 50:1 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No Speed Speed Speed Yes No Required Yes Included Included with Hp Resistor Yes No Required Yes Included Included with Hp Resistor Yes No Required Yes Included Included with Hp Resistor Yes Yes Yes Yes Yes Timed or Non-Timed Speed or Torque Yes Yes N/A Yes External Not Supplied with Control Yes Yes Yes Yes Yes Timed or Non-Timed Speed or Torque Yes Yes N/A Yes External Yes Yes Yes Yes Yes Timed or Non-Timed Speed or Torque Yes Yes N/A Yes External Not Supplied with Control Standard Standard Standard Opt - BC159 No Standard No No No No Opt-BC144 No Opt-BC156 Opt-BC153 No No Standard Opt-BC153 No No No Opt-BC157 Opt-BC157 Standard External Mount Opt-BC145 Internal Mount Opt-BC145 Internal Mount Opt-BC145 Internal Mount Opt-BC145 Opt-BC145 (0-5, 0-10 VDC) input standard (0-5, 0-10 VDC) input standard (0-5, 0-10 VDC) input standard Standard Standard Standard Standard Standard Standard Standard Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Control Of Speed or Torque IR Compensation Adjustable Tachometer Feedback Input Plug-In Horsepower Resistor ® UL & cUL Listing, CE AC Line Fuse DC Armature Fuse Options AC Line Switch Forward/Brake/Reverse Switch Mechanical Electronic Run/Jog Switch Input Signal Following Mode Capability Current (1-5, 4-20, 20-50mA) No No Voltage (0-25,0-120, 0-550 VDC) Electrical Connection To Control Barrier Terminal Block Current Sensing Relay/Overload Protector AC Line Filter for CE Standard Standard No No Opt-BC24-LF Opt-BC24-LF 1 Hp 2Hp Opt - BC146 External Mount Opt-BC24-LF BC160 External BCWD140 NEMA 4X Washdown NEMA K 115 230 90 180 100/200 1/25-2 Not Required Chassis Mount DC Control Specifications 1/100-1.5 1/50-3 1 Hp-Up 2 Hp-Up 50:1 50:1 50:1 50:1 Yes Yes Yes Yes Yes Yes Yes Non Timed Yes Yes Yes Non Timed Yes Yes Yes Non Timed Speed Speed Speed Yes Yes Required Yes Included Included with Hp Resistor Yes Yes Required Yes Included Included with Hp Resistor Yes Yes Required Yes Included Included with Hp Resistor Yes Yes Yes Non Timed Speed Torque Yes Yes N/A Yes External Included with Hp Resistor Current (4-20 mA) Plug on Mount Opt-BC152 Plug on Mount Opt-BC152 Plug on Mount Opt-BC152 Current (1-5, 4-20, 20-50 mA) External Mount Opt-BC145 External Mount Opt-BC145 External Mount Opt-BC145 0-9 VDC Standard 0-9 VDC Standard 0-9 VDC Standard Plug on Mount Plug on Mount Plug on Mount Opt-BC152 Opt-BC152 Opt-BC152 External Mount Opt-BC145 External Mount Opt-BC145 External Mount Opt-BC145 Standard Opt-BC147 Standard Opt-BC147 Opt-BC146 Rated Horsepower Range External Heat Sink (BC143) Required Speed Range (Motor may be 20:1Constant Torque) Adjustable Acceleration Adjustable Deceleration Min.. Speed Adjustable Max. Speed Adjustable Adjustable Current Limit and Tripout Type Control of Speed or Torque IR Compensation Adjustment Tachometer Feedback Input Plug-in Horsepower Resistor® UL & cUL Listing, CE AC Line Fuse DC Armature Fuse 50:1 BC203 Chassis Regenerative 230 180 100/200 100/200 1/4-1-1/2 1/2-3 Not Required Not Required 50:1 50:1 50:1 5 Yes Yes Yes Yes Fwd & Rev Regen No Yes Non Timed Speed or Torque Yes Yes N/A Yes External Fwd & Rev Regen No Yes Fwd & Rev Regen No Yes Fwd & Rev Regen No Yes Timed Timed Timed Speed or Torque Yes Yes N/A Yes Included Speed or Torque Yes Yes N/A Yes Included Yes Yes N/A Yes External External N/A N/A External External Mount Opt-BC145 No No No No 0-9 VDC Standard 0 to ± 10 VDC Standard 0 to ± 10 VDC Standard 0 to ± 10 VDC Standard 0 to ± 10 VDC Standard External Mount Opt-BC145 ±5 to ±25 VDC Opt-BC215 ±25 to ±250 VDC Opt-BC212 ±25 to ±250 VDC Opt-BC212 ±25 to ±250 VDC Opt-BC212 Standard Opt-BC147 No Standard Standard N/A No Standard No Standard No Standard Opt-BC146 Opt-BC146 Opt-BC146 N/A Standard Standard No Standard No No No No No Opt - BC211 Opt - BC211 Opt - BC211 Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Unit Handling Motors 100/200 BC201 Chassis Regenerative 115 230 90 180 Brake Motors 50/100 BC200 Chassis Regenerative 115 230 90 180 50/100 100/200 1/4-1 1/2-2 Not Required Speed Options 200 & 575 Volt Motors BC142 Chassis NEMA K 230 180 Enclosure Control Type AC Line Input DC Armature Voltage Nominal Shunt Field Power Supply Voltage - DC BC142-6 Chassis NEMA K 115 230 90 180 50/100 100/200 1/100-1 1/2 1/50-3 1/2 Hp-Up 1 Hp-Up Catalog Number BC155 BC204 Chassis Chassis NEMA K Regenerative 230 115 230 180 90 180 50/100 50/100 100/200 100/200 1/8-1 5 1/4-2 Not 90V-1Hp Required 180V-2Hp BC141 Chassis NEMA K 115 90 IEC Frame Motors Features Definite Purpose Motors Farm Duty Motors DC Motors & Controls Voltage (0-25, 0-120, 0-550 VDC) Electrical Connection To Control Push-On Quick Connects Barrier Terminal Block Current Sensing Relay/ Overload Protector Regenerative Accel / Decel Board AC Line Filter for CE Inverter/Vector Motors & Controls 0-200, VDC) DC Motors and Controls Voltage (0-5, 0-10, 0-100, Soft Starters & Dynamic Brakes Input Signal Voltage (must be isolated) 50 Hertz Motors Input Signal Following Mode Capability 261
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Creator : Title : Baldor DC Motor Controls - MotionUSA - Your Source for High Speed and High Precision Subject : Baldor DC Motor Controls - MotionUSA - Your Source for High Speed and High Precision Create Date : 2013:02:18 11:01:37Z Creator Tool : Adobe Acrobat 10.1.4 Modify Date : 2014:01:06 12:59:40-05:00 Metadata Date : 2014:01:06 12:59:40-05:00 Producer : GPL Ghostscript 8.15 Keywords : Baldor DC Motor Controls - MotionUSA - Your Source for High Speed and High Precision Document ID : uuid:848623e6-dd3c-44db-b0c7-22c42bebb0f8 Instance ID : uuid:686f84f1-65ff-4bd6-8d2b-ca9d2cdeaca3 Page Count : 24 Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools