GE BallastBrochure11 08 648355 Catalog 1
529707-Catalog 529707-Catalog 529707-Catalog 768386 Batch5 unilog cesco-content
2014-07-05
: Pdf 648355-Catalog 1 648355-Catalog_1 768386 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 73
Download | |
Open PDF In Browser | View PDF |
GE BALLAST PRODUCTS CATALOG FEATURING: TRANSFORMING THE POWER OF LIGHT ™ TM ULTRA ELECTRONIC BALLASTS GE BALLAST PRODUCTS CATALOG FEATURING U L T R AMAX ™ ELECTRONIC BALLAST Breakthrough technology that dramatically improves efficiency, simplifies installation and delivers optimal lamp performance. TABLE OF CONTENTS Electronic Ballasts Featuring New UltraMax™ Technology Product Overview . . . . . . . . . . . . . . . . . . . . . .1-1 UltraMaxTM Electronic Ballasts Overview . . . . . . .1-2 UltraMaxTM System Performance Matrix . . . . . .1-7 UltraMaxTM Ordering Guide and System Wattage 1-8 Additional Electronic Ballast Overview . . . . . . . .1-9 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-11 Performance . . . . . . . . . . . . . . . . . . . . . . . .1-12 Specifications . . . . . . . . . . . . . . . . . . . . . . .1-14 Ballast Matrix . . . . . . . . . . . . . . . . . . . . . . .1-18 F17T8 . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-20 F25T8 . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-21 F28T8 . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-22 F32T8 . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-23 F40T8 . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-28 F96T8 Slimline . . . . . . . . . . . . . . . . . . . . . .1-29 T8HO . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-30 T5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-31 T10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-32 T12 Rapid Start . . . . . . . . . . . . . . . . . . . . . .1-33 T12 Slimline . . . . . . . . . . . . . . . . . . . . . . . .1-36 T12HO High Output . . . . . . . . . . . . . . . . . . .1-37 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . .1-38 Dimming Product Overview . . . . . . . . . . . . . .1-40 Dimming Application and Operating Information 1-41 Dimming Specifications . . . . . . . . . . . . . . . . .1-42 Dimming Controls Cross Reference . . . . . . . .1-43 Dimming T8 . . . . . . . . . . . . . . . . . . . . . . . .1-44 Dimming Wiring Diagrams . . . . . . . . . . . . . .1-46 Fluorescent Electromagnetic Ballasts Product Overview . . . . . . . . . . . . . . . . . . . . . .2-1 Application and Operation Information . . . . . . . .2-4 Typical Specifications . . . . . . . . . . . . . . . . . . .2-7 Lead Lengths . . . . . . . . . . . . . . . . . . . . . . . .2-8 F40T12 . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9 F40T10 . . . . . . . . . . . . . . . . . . . . . . . . . . .2-11 T12 High Output . . . . . . . . . . . . . . . . . . . . .2-12 T12 Very High Output . . . . . . . . . . . . . . . . . .2-14 F96PG17 . . . . . . . . . . . . . . . . . . . . . . . . . .2-15 F96T12 Very High Output . . . . . . . . . . . . . . .2-15 T12 Slimline . . . . . . . . . . . . . . . . . . . . . . . .2-16 Circline . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-18 Preheat and Trigger . . . . . . . . . . . . . . . . . . .2-19 Dimming . . . . . . . . . . . . . . . . . . . . . . . . . . .2-21 Export . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-22 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . .2-23 Sign Illuminating Ballasts Product Overview . . . . . . . . . . . . . . . . . . . . . .3-1 Application and Operation Information . . . . . . . .3-2 High Output Sign Ballasts . . . . . . . . . . . . . . . .3-3 Lead Length & Ballast Footage . . . . . . . . . . . . .3-4 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . .3-5 Compact Fluorescent Ballasts Product Overview . . . . . . . . . . . . . . . . . . . . . .4-1 Understanding Compact Fluorescent Technology .4-3 Specifications . . . . . . . . . . . . . . . . . . . . . . . .4-4 Understanding Part Numbers . . . . . . . . . . . . .4-5 Twin/Quad Lamps 5-13 Watts . . . . . . . . . . . . .4-6 Twin/Quad/Multiple Lamps 13-26 Watts . . . . . .4-7 Multiple Lamps 32-70 Watts . . . . . . . . . . . . .4-8 2D Lamps 10-38 Watts . . . . . . . . . . . . . . . . .4-9 T5 Circular Lamps 22-40 Watts . . . . . . . . . .4-11 T5 Long Twin Lamps 24-96 Watts . . . . . . . . .4-12 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . .4-15 High Intensity Discharge (HID) Ballasts Product Overview . . . . . . . . . . . . . . . . . . . . . .5-1 Application and Operation Information . . . . . . . .5-5 Nomenclature . . . . . . . . . . . . . . . . . . . . . . .5-10 Specifications . . . . . . . . . . . . . . . . . . . . . . .5-11 Distributor Replacement Kits . . . . . . . . . . . . .5-12 Core and Coil . . . . . . . . . . . . . . . . . . . . . . .5-14 Metal Halide . . . . . . . . . . . . . . . . . . . . . .5-14 Pulse Start Metal Halide . . . . . . . . . . . . .5-19 High Pressure Sodium . . . . . . . . . . . . . . .5-22 Mercury . . . . . . . . . . . . . . . . . . . . . . . . .5-26 F-Can Ballasts . . . . . . . . . . . . . . . . . . . . . . .5-27 HID Controls/Part Numbers & Accessories . . .5-29 Ignitors . . . . . . . . . . . . . . . . . . . . . . . . . . .5-31 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . .5-32 Glossary Warranty For more information, visit www.gelighting.com ELECTRONIC FLUORESCENT BALLASTS COMPREHENSIVE RANGE OF SOLUTIONS ... FROM THE NAME YOU TRUST GE introduced the first fluorescent ballast more than 60 years ago. Today we are providing high frequency electronic ballasts for almost every fluorescent application. PRODUCT OVERVIEW A With our UltraMaxTM Ballasts, we are bringing you the future in ballast performance. GE revolutionizes lighting again with new, breakthrough technology. Our patented UltraMax™ electronic ballasts transform the power of light into efficiency and savings from store shelves to the installation site. It all starts with UltraMax's Multi-Voltage Control (MVC), which automatically adjusts to handle voltage from 120V through 277V. That cuts the ballast models you need to stock from 40 down to 13, which can dramatically reduce inventory carrying costs. UltraMax™ ballasts have ArcGuard Protection, too, with a UL Type CC Anti-Arc Rating. Plus, they’re ultra lamp friendly, with an industry low Lamp Current Crest Factor of 1.4 for optimal lamp performance. And the small, low-profile design of the UltraMax™ ballasts makes retrofits effortless at the job site. GE offers electronic ballasts for a wide range of applications. For more information, visit www.gelighting.com 1-1 U L T R A MAX U L T R A MAX ELECTRONIC BALLAST High efficiency delivers up to 40% energy savings. Ballasts are the new frontier of energy efficiency. Systems combining UltraMaxTM electronic ballasts and T8/WM lamps can deliver up to 40% energy savings over standard electromagnetically ballasted T12 systems. Since energy costs are typically 80% of the overall cost of light, a more efficient system can pay for itself in a very short time and provide an excellent return on investment. UltraMaxTM is ultra lamp friendly. With an industry low lamp current crest factor (LCCF) of 1.4, UltraMaxTM ensures optimal lamp operation and maximum lamp life, which can save on lamp and maintenance costs. COMPARE THE ENERGY USE OF A THREE LAMP FIXTURE 117 watts 1 STANDARD T12/WM SYSTEM 2 STANDARD ELECTRONIC T8 SYSTEM 3 ULTRAMAXTM L SYSTEM WITH GE T8 WATT-MISER 1-2 1 87 watts 2 ELECTRONIC BALLAST Fully parallel independent lamp operation makes system easier to maintain. If one lamp fails, all the others in the system stay lit. That means system maintenance is easier to manage. UltraMaxTM is ultra-cool. UltraMax’s high efficiency design results in ultra-cool operation that can provide additional AC energy savings, especially during peak demand periods. A big idea in a small package. The UltraMaxTM housing is smaller, lower-profile and lightweight. That can be a big help in retrofits. It also means future fixture designs can be more compact and streamlined. Every unit is tested and proven before it’s shipped. GE does 100% burn-in on every UltraMaxTM ballast using our extreme open/short test, which simulates undesirable and harsh-use situations, so you are assured of a system you can rely on right out of the box. GE Six Sigma quality backed by a full 5-year warranty. UltraMaxTM is designed by GE’s expert engineers and custom-manufactured to our exacting Six Sigma specifications, all backed by a full 5-year warranty. 68 watts 3 transforming the power of light ™ L The Low watt option for Max energy savings. With a ballast factor of .77, the L line is the most energy efficient choice. It provides adequate illumination for most applications. For 1, 2, 3, and 4 T8 lamps in 2’, 3’, and 4’ lengths. U L T R AMAX ELECTRONIC BALLAST ELECTRONIC BALLAST H The choice for High light output. With a ballast factor of 1.15, UltraMaxTM H delivers the most lumens for maximum light or when you want more savings using fewer lamps. This is the first highefficiency high-light output line for 2, 3 and 4 T8 lamps. UltraMax™ electronic ballasts have 5% more energy efficiency than standard electronic ballasts. When combined with GE T8 WattMiser® lamps, it means up to 40% in energy savings. UltraMaxTM ballasts perform. L .77 4389 48 91 N .87 4959 53 94 1.15 6555 73 90 N The Normal light option balances efficiency and illumination. The most-used type of ballast, the N line saves energy without sacrificing lumens. A ballast factor of .87 meets most application needs. For 1, 2, 3, and 4 T8 lamps in 2', 3', 4', and 8' lengths. U L T R AMAX See for yourself how different LUMENS PER WATT Anti-Striation Control for better light quality, with no striations. UltraMaxTM is the only line of T8 ballasts with Anti-Striation Control. This advanced technology eliminates the maintenance issues caused by striating lamps, often referred to as spiraling or swirling. This provides a flicker- and worry-free environment. ULTRAMAXTM ELECTRONIC BALLASTS U L T R AMAX *INPUT WATTS UltraMaxTM is the only full line of T8 ballasts with a UL Type CC Anti-Arc Rating. UL Type CC Rating is a stringent designation of protection against arcing in electrical devices. GE’s Arc-Guard design eliminates the damaging effects arcing can have on lamps, ballasts and sockets. A FULL FAMILY OF HIGH EFFICIENCY MULTI-VOLTAGE BALLASTS FOR ALL T8 APPLICATIONS. (2850 Lumens/Lamp) Multi-Voltage technology means a single UltraMaxTM model handles voltage from 120 through 277. UltraMaxTM Ballasts can virtually “read’’ the incoming voltage and adapt automatically to any voltage from 108V to 305V. The benefits of MultiVoltage Control (MVC) are obvious: • Fewer models handle more jobs, eliminating inventory hassles. • MVC simplifies installation and eliminates guesswork at the job site. • MVC compensates for incoming voltage fluctuations or variations from unreliable power. Active Current Regulation (ACR) technology is a patented advantage. UltraMax’s patented ACR modular design means individual inverter modules regulate the output current to each lamp. So, unlike conventional ballasts, if one lamp fails, the remaining lamps are not forced to operate at a higher current. This ensures optimal lamp performance. H *SYSTEM LUMENS GE revolutionizes lighting again with new, breakthrough technology. In the GE labs, our engineers have developed a new breed of ballasts to make lighting systems that save more energy, are more adaptable, and deliver optimal lamp performance. The innovative, patented technology in our new UltraMaxTM electronic ballasts exceeds expectations, and is like nothing else available. BALLAST FACTOR ULTRAMAXTM ELECTRONIC BALLASTS ELECTRONIC BALLAST * For a 2-Lamp F32T8 System at 277V Safety • No PCBs • UL Listed - Class P, Type 1 - Type CC - Type HL (Hazardous Location) Application Information • Minimum Starting Temperature: 0°F, -18°C • Maximum Ambient Temperature: 105°F, 40°C • Sound Rated A • Remote Mounting: 18' maximum lead length, 18 AWG • High Frequency Lamp Operation: Above 60 kHz Physical Parameters (Except for the 4H model) Length: 9.50 in. Width: 1.70 in. Height: 1.2 in. Weight: 1.4 lbs. Applications: Offices Retail Schools Universities Plants Hotels Warehouses Hospitals For more information, visit www.gelighting.com 1-3 U L T R A MAX U L T R A MAX ELECTRONIC BALLAST ELECTRONIC BALLAST A SMALLER, LOWER PROFILE DESIGN IS A BIG IDEA FOR EFFICIENT INSTALLATION. B It’s easy to see how smaller, lower-profile UltraMaxTM ballasts make even the toughest retrofits into easy fits. ULTRAMAXTM ELECTRONIC BALLASTS WHEN YOU WANT LIGHTING DONE RIGHT, START WITH GE. PHYSICAL DIMENSIONS For Ballast types L, N and H (except 4H) W NE OVERALL DIMENSIONS A (length) 8.375 in. (21.273 cm) B (width) 1.25 in. (3.175 cm) D A C (height) 1.125 in. (2.858 cm) MOUNTING DIMENSIONS Up to 40% in energy savings 13 models can replace more than 40 conventional electronic ballasts One patented GE ballast handles 120V through 277V D (length) 8.875 in. (22.54 cm) E (width) 1.4375 in. (3.651 cm) WEIGHT RANGE C E 1.00 to 1.50 lbs. (0.454 to 0.6804 kg.) TRANSFORMING POWER OF THE LIGHT™ 1-4 transforming the power of light ™ For more information, visit www.gelighting.com 1-5 U L T R A MAX U L T R A MAX ELECTRONIC BALLAST ELECTRONIC BALLAST CHOOSING THE RIGHT BALLAST IS SIMPLE. SYSTEM PERFORMANCE COMPARISON MATRIX The easy-to-understand model numbering system helps you choose and install the right model. Instructions and wiring diagrams on each ballast label help assure a correct installation the first time. Compare the overall performance of a GE UltraMaxTM system to conventional lamp and ballast systems. Lamps Electronic Ballasts Electromagnetic Ballasts ULTRAMAXTM ELECTRONIC BALLASTS 2-Lamp System Performance 4' Fluorescent TOTAL PERFORMANCE SYSTEM™ WARRANTY Electromagnetic E.S. Rapid Start Low Power (L) Normal UltraMaxTM L UltraMaxTM N UltraMaxTM H Watt-Miser T12 (CW) Watts: 74 BF: 0.90 Light: 100% RLPW: 100% Watts: 64 BF: 0.86 Light: 96% RLPW: 110% Not Available Not Available Not Available Not Available Not Available F32T8 & F32T8/XL (SP) Watts: 69 BF: 0.88 Light: 116% RLPW: 125% Watts: 63 BF: 0.88 Light: 116% RLPW: 137% Watts: 51 BF: 0.78 Light: 103% RLPW: 149% Watts: 58 BF: 0.88 Light: 116% RLPW: 148% Watts: 48 BF: 0.77 Light: 102% RLPW: 157% Watts: 53 BF: 0.87 Light: 115% RLPW: 160% Watts: 73 BF: 1.15 Light: 152% RLPW: 154% F32T8/WM ULTRA & XL (SP) Not Recommended Not Recommended Watts: 48 BF: 0.78 Light: 102% RLPW: 157% Watts: 54 BF: 0.88 Light: 115% RLPW: 157% Watts: 46 BF: 0.77 Light: 100% RLPW: 161% Watts: 52 BF: 0.87 Light: 113% RLPW: 161% Watts: 70 BF: 1.15 Light: 150% RLPW: 158% Electromagnetic E.S. Rapid Start Low Power (L) Normal UltraMaxTM L UltraMaxTM N UltraMaxTM H Watt-Miser T12 (CW) Watts: 117 BF: 0.91 Light: 100% RLPW: 100% Watts: 93 BF: 0.86 Light: 95% RLPW: 119% Not Available Not Available Not Available Not Available Not Available F32T8 & F32T8/XL (SP) Watts: 105 BF: 0.88 Light: 115% RLPW: 128% Watts: 93 BF: 0.88 Light: 115% RLPW: 145% Watts: 77 BF: 0.78 Light: 102% RLPW: 155% Watts: 87 BF: 0.88 Light: 115% RLPW: 155% Watts: 72 BF: 0.77 Light: 101% RLPW: 163% Watts: 80 BF: 0.87 Light: 114% RLPW: 166% Watts: 109 BF: 1.15 Light: 150% RLPW: 161% F32T8/WM ULTRA & XL (SP) Not Recommended Not Recommended Watts: 72 BF: 0.78 Light: 101% RLPW: 163% Watts: 81 BF: 0.88 Light: 113% RLPW: 164% Watts: 68 BF: 0.77 Light: 99% RLPW: 171% Watts: 77 BF: 0.87 Light: 112% RLPW: 170% Watts: 104 BF: 1.15 Light: 148% RLPW: 167% Electromagnetic E.S. Rapid Start Low Power (L) Normal UltraMaxTM L UltraMaxTM N UltraMaxTM H Watt-Miser T12 (CW) Watts: 148 BF: 0.90 Light: 100% RLPW: 100% Watts: 128 BF: 0.86 Light: 96% RLPW: 110% Not Available Not Available Not Available Not Available Not Available F32T8 & F32T8/XL (SP) Watts: 138 BF: 0.88 Light: 116% RLPW: 125% Watts: 120 BF: 0.88 Light: 116% RLPW: 143% Watts: 100 BF: 0.78 Light: 103% RLPW: 152% Watts: 114 BF: 0.88 Light: 116% RLPW: 151% Watts: 96 BF: 0.77 Light: 102% RLPW: 158% Watts: 107 BF: 0.87 Light: 115% RLPW: 159% TBD F32T8/WM ULTRA & XL (SP) Not Recommended Not Recommended Watts: 95 BF: 0.78 Light: 102% RLPW: 158% Watts: 107 BF: 0.88 Light: 115% RLPW: 159% Watts: 91 BF: 0.77 Light: 100% RLPW: 163% Watts: 103 BF: 0.87 Light: 113% RLPW: 163% TBD Here are the facts behind the promise. It starts with precision manufacturing. GE UltraMaxTM Electronic Ballasts are custom-manufactured to our exacting specifications. We work to assure you the AXT R ABM reliability and quality you expect from GE. LLAS T A L C U CTRONI h t. Manufacturing processes include rigorous testing and ELE e ri gh t lig a n ce . T h p er fo rm t gh ri e quality control. Quality standards are further assurance . Th t b a lla st T h e ri gh ty ™ Warran of trouble-free performance. ystem ng GE TM x ce S coveri rformanfollowing warrantyllasts. e P l ta o e a T b th provide lectronic ations an UltraMag is pleased to GE UltraMax e specific • 100% burn-in of units to assure reliability. blished tin d ective pu n sp a re that s eir p GE Ligh m ballasts y with th ctronic st scent la s compl • GE’s extreme open/short Test which tests units’ the balla Max ele d ballast title. T8 fluore GE Ultra lues shown on tal lamps an kmanship and on at ed th at va en s e oper , wor arrant ctrical vironm w ar ial e of en ele g er ps e d ng at tin th ra an m E lam ing ithin tion; GE Ligh m defects in ability to withstand severe current conditions. when G d operat erated w for the applica fro ly applies stalled; are op al specifie ed are free in ranty on the d approv within the norm g an rin d This war erly wired and du ne e p desig ent) ar in the lam purchase, en prop uipment movem • Careful component selection and extensive testing ors with have be and air hting eq e to fact after the date of ps which ed in lig humidity ts fail du st, lam label; us (temperature, quiremen ever comes fir plies to re ns ap e y itio ov nt nd ra co of elements prior to final approval. g the ab n, which This war e (5) em. operatio s meetin charge. initial fiv the syst in system 10,500 hours of t lamps at no ring the If lamps ballast du her replace the s or emen more. ithin the eit e (3) year to furnish replac hours/start or w • Critical component placement and extensive testing re s ge . th or ar l st ch fact 10 initia balla es cycle of llast fails due to option, will at no se price of the e of ting agre GE Ligh ed on a burning the caus al ronic ba Lighting, at its e purcha termine at E TM elect abnorm refund th ballasts to de are oper of elements prior to final approval. UltraMax manufacture, G allowance or y to any including or pl d/ ap an t If a GE no or ps ns te of a lab failed lam st warranties do use in installatio s ter the da cluding paying r examine riter years af balla e ctions fo Underw ballast in rves the right to ese lamp and • Extensive lamp/ballast system testing which ensure nada, th or instru s for Safety of defective I) or, in Ca ting rese lamp usage. Th standard, code rd NS da (A an te St GE Ligh Institu rns of ), The icable s pl tte rd EC ap pa (N da y E d G an de an optimal operating performance and compatibility. failure an in violation of ectric Co ican National St liability of e tional El er the sole TNESS FOR A use or us ained in the Na rds for the Am ser and FI nt e purcha e for any LITY OR anda those co edy of th ERCHANTABI Lighting be liabl (UL), St (CSA). m n c. re In tio • Comprehensive testing under adverse field and e ry, M cia siv E NTY OF Laborato Standards Asso titute the exclu t shall G ages. WARRA no even ns m da ial nt Canadian regoing shall co warranties. NO BE IMPLIED. In conseque st The fo accelerated life conditions to prevent failure in the and balla MADE OR IS TO ental, special or id for lamp IS Lighting AR PURPOSE ing lost profits, inc UL lud IC inc RT es PA ag field. st of dam other co • Commitment to Six Sigma standards for worldclass product and service excellence. • Power line voltage spike protection that passes MING SFOR OF TRAN WER the IEEE surge test (where a 6000V pulse is O THEP T H LIG applied to input leads). Compliance with all appropriate regulatory standards. • Contact your GE representitive for specific warranty details. TM d ULTRAMAXTM ELECTRONIC BALLASTS 1 = Maximum number of lamps supported by this ballast. 32 = Lamp watts (primary lamp) N = Normal ballast (ballast factor of .87) 3-Lamp System Performance 4' Fluorescent TM 4-Lamp System Performance 4' Fluorescent ™ Notes: Light refers to "mean" lumen output relative to highlighted T12 Electromagnetic E.S. (energy saving) ballast systems. RLPW is mean system Lumens/Watt relative to highlighted T12 Electromagnetic E.S. (energy saving) ballast systems. Watts shown at 277 Volts. 1-6 transforming the power of light ™ For more information, visit www.gelighting.com 1-7 U L T R A MAX ELECTRONIC BALLAST ORDERING GUIDE AND SYSTEM WATTAGE # Lamps Power High Instant Start Normal Low ULTRAMAXTM ELECTRONIC BALLASTS Starting GE UltraMax Ballasts Product Description Code 1 49706 GE-132-MAX-L/Ultra 2 49707 GE-232-MAX-L/Ultra 3 49708 GE-332-MAX-L/Ultra 4 49709 GE-432-MAX-L/Ultra 1 49771 GE-132-MAX-N/Ultra 2 49772 GE-232-MAX-N/Ultra 3 49773 GE-332-MAX-N/Ultra 4 49774 GE-432-MAX-N/Ultra 2 49775 GE-232-MAX-H/Ultra 3 49776 GE-332-MAX-H/Ultra 4 49777 GE-432-MAX-H/Ultra Input Voltage Normal † ∆ 1-8 1 49766 GE-159-MAX-N/Ultra 2 49767 GE-259-MAX-N/Ultra F32T8 Input Watts F32T8/WM Input Watts F28T8/WM Input Watts Input In Fixture∆ Input Watts† Open Enclosed Watts† In Fixture∆ Input † Open Enclosed Watts Units Input Fixture∆ Per Open Enclosed Case Multi-Volt 120 277 Multi-Volt 120 277 Multi-Volt 120 277 Multi-Volt 120 277 25 25 48 48 73 72 97 96 24 24 48 48 72 71 95 93 24 24 47 47 71 70 93 92 24 24 46 46 69 68 92 91 23 23 46 46 68 67 90 89 23 23 45 45 67 66 88 87 22 22 44 44 65 65 87 86 TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD Multi-Volt 120 277 Multi-Volt 120 277 Multi-Volt 120 277 Multi-Volt 120 277 28 28 54 53 82 80 109 107 28 28 54 53 80 78 105 103 27 27 53 52 78 77 103 101 27 27 53 52 78 77 105 103 26 26 52 51 77 75 101 99 26 26 51 50 74 73 98 97 25 25 49 48 72 71 98 96 TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD Multi-Volt 120 277 Multi-Volt 120 277 Multi-Volt 120 277 74 73 111 109 151 147 71 70 105 103 TBD TBD 69 68 102 100 TBD TBD 71 70 106 104 145 141 69 68 102 100 TBD TBD 67 66 97 96 TBD TBD 66 65 97 96 133 131 TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD GE UltraMax Ballasts Product Description Code AccuStart® and Universal Voltage Low Profile High Performance (HP-A & HP-B) F96T8 Input Watts F96T8/WM Input Watts Input Voltage Input Watts† In Fixture∆ Input † Watts Open Enclosed In Fixture∆ Open Enclosed Multi-Volt 120 277 Multi-Volt 120 277 56 55 112 110 TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD 54 53 107 105 TBD TBD TBD TBD 10 10 10 10 10 10 10 10 AccuStart® ballasts are ideal for frequently switched applications or as a rapid start alternative. They incorporate patented programmed rapid start technology to properly heat the lamp filaments, which yields an increase in lamp life up to 50%. The 1-4 lamp models offer universal input voltage. Our low profile High Performance ballasts with THD <10% offer the convenience of universal input voltage (108-305 Volts) as a standard feature. Universal input is "installer-friendly" – ensuring that you have the right voltage ballast every time. Our low profile models also feature a package and cross-section that can offer greater flexibility in fixture design (1.0" height x 1.5" width). Since the mounting and wiring footprints are the same as a standard ballast, our low profile HP models will easily retrofit into any T12 or T8 fixture. Low Profile Reduced Harmonic (RH-A) Our low profile RH ballasts are over 45% smaller and 30% lighter. They feature a space-saving package (1.18" height x 1.7" width) and cross section for greater flexibility in fixture design. The 1-4 lamp model features parallel lamp operation, with standard mounting footprint and wiring for ease of replacement. They offer high efficiency performance with THD <20%. PRODUCT OVERVIEW PRODUCT OVERVIEW There’s a combination of GE UltraMax™ ballasts and T8 lamps that can make virtually any lighting system perform better. The chart below lets you see for yourself. 10 10 10 Units Per Case 10 10 Low profile RH ballasts. AccuStart® ballasts for frequently switched applications. Flexible fixture design options for T5 lamps. Denotes standard laboratory non-fixture open bench testing. In fixture watts represent typical field operating conditions with ballast and lamps in fixture/luminaire. Open fixture denotes non-lensed fixture/luminaire. Enclosed fixture denotes lensed fixture/luminaire. transforming the power of light ™ For more information, visit www.gelighting.com 1-9 ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS T5 systems are gaining greater popularity for high-end architectural applications. GE provides a wide range of T5 solutions, from 14 to 54 watts. Our T5 ballasts operate multiple (1 or 2) F35T5, F28T5, F21T5 and F14T5 lamps. Additionally, our T5HO ballasts operate multiple (1 or 2) F54T5HO, F39T5HO and F24T5HO lamps. Moreover, they make your life easier with standard features that include universal input voltage (108-305 Volts), programmed rapid start technology for longer lamp life and end of lamp life shutdown circuit with auto-reset. T5 High Output High output T5 ballasts from GE support 24-, 39- and 54-watt lamps and they offer the same standard features and compact dimensions as our T5 standard output. They're also well-suited to applications where space is at a premium, including slim pendant mounted fixtures, cove and task lighting. T5 Standard Output Our standard output ballasts for T5 applications support multiple lamp operation (including 14, 21, 28, and 35 watts). They're ideal for indirect pendant mount, surface mount, cove, undercabinet or task lighting. With a small cross section (1.0"height x 1.18"width), our T5 models give you more options for slim fixture design. Standard features include universal input voltage, end-oflamp-life shutdown circuit and programmed rapid start technology. SAFETY NEC & UL Requirements Ballast installation presents the possibility of exposure to potentially hazardous voltages and should be performed only by qualified personnel. All installation, inspection, and maintenance should be performed only with power to the fixture turned off. Additionally, all fixtures and ballasts must be installed and operated in compliance with the National Electrical Code, Underwriters Laboratories Inc. (UL) requirements, and all local applicable codes and regulations. Polarity Polarity refers to the proper connection of ballast lead wires to line wires. To aid you in making a correct installation, GE ballast leads are color-coded for easy identification. The WHITE ballast lead is to be connected to the neutral (grounded) and the BLACK (or black with white tracer) lead always to the phase (“hot”) line wire. Systems where neither of the line wires are at ground potential require specially designed ballasts. A change in polarity may result in the voltage from the lead to the ground exceeding UL-specified limits. In some types of ballasts, a change in polarity may decrease voltage from the lead to the ground, thereby impeding the starting dependability of the ballast. Grounding Ballast cases and fixtures must always be grounded. The ballast case may be grounded to the fixture or otherwise grounded. It could be hazardous to make contact with an ungrounded fixture or ballast when in operation. Neglecting to properly ground the ballast and fixture combination may also result in failure of certain lamps to start or for unacceptable levels of electromagnetic noise to be conducted onto the power lines. Operating Line Voltage Limits To receive the full benefits of rated lamp output and to prolong ballast life, it is essential that voltage supplied to an installation be maintained within limits prescribed for each circuit. These limits are listed in the next column. 1-10 transforming the power of light ™ VOLTAGE RANGE Nominal Voltage 120 220 277 347 120-277 (UNV) Minimum 108 198 249 312 108 Maximum 132 242 305 382 305 Subjecting a ballast to excessive voltage for an extended period results in the deterioration of the insulation. This insulation breakdown will cause early ballast failure. Low voltage has no damaging effect on the ballast. However, lamps may not start reliably, and early lamp failure could result. APPLICATION AND OPERATING INFORMATION PRODUCT OVERVIEW T5 BALLASTS FOR INDIRECT, HIGH-END ARCHITECTURAL APPLICATIONS Internal Ballast Protection Class P Classification—Since January 1, 1984, the National Electrical Code requires that “where Fluorescent fixtures are installed indoors, the ballast shall have thermal protection integral within the ballast except for simple reactance ballasts.” This ruling applies to replacement ballasts as well as to those contained within new fixtures. In compliance with the National Electrical Code, UL has established a Class P ballast classification for fluorescent light fixtures. A Class P ballast must employ internal thermal protection limiting its operating temperature. GE UL-approved Class P ballasts comply with the National Electrical Code requirement and are equipped with an automatic resetting thermal protector, built-in and adjacent to the transformer coils. The resetting thermal protector functions as a thermostat, which will open and temporarily deactivate the ballast when it exceeds the permissible temperature. It will reset when the ballast cools to a safe operating temperature. The ballast will continue to cycle until the cause of overheating is eliminated. If the ballast is defective, it must be replaced. If the cause is external, a Class P ballast will resume normal operation after abnormal conditions are eliminated. For more information, visit www.gelighting.com 1-11 APPLICATION AND OPERATING INFORMATION SAFETY PERFORMANCE PERFORMANCE, continued Dimming Ballasts - Ballastar® dimming ballasts from GE are controlled by using 10-0vDC. Care should be taken to ensure that the line voltage (AC) wires are not connected to the low voltage DC wires. Ballastar® electronic dimming ballasts have protection (safety) circuitry that will sense the error so as not to harm the installer or the ballast. Dimming ballasts manufactured after May 1999 have the protection circuit. Dimming ballasts manufactured before this date do not have low voltage circuit protection. Lamp Connections Fluorescent ballasts are designed to generate voltages in excess of 300 Volts. It is imperative that proper connection to quality sockets be assured in accordance with wiring diagrams on each page of the catalog and on product labels. Some applications may not require the use of all of the ballast output leads. If any leads are not to be connected, each should be individually capped and insulated to at least 600 Volts. Lamp Starting Dependability Fluorescent lamps are inherently more difficult to start at low temperatures. All ballasts have limitations as to their ability to start lamps at low ambient temperatures. In this catalog, the low starting point for each lamp/ballast combination appears in the column marked “Minimum Starting Temperature.” Four lamp instant start ballasts can operate at a minimum starting temperature down to -18°C (0°F) under the following conditions: 1. Lead lengths to the lamps are those supplied, by GE, with the ballast or shorter. 2. The distance from the lamp to the ground plane is no greater than 3/4". 3. The line voltage supplied to the ballast is no less than rated nominal. 4. The ballast or lamps are not remotely mounted. 5. The lamps have been burned in per lamp manufacturer requirements (typically 100 hours). Contact GE for lamp operating characteristics and requirments below 15°C (50°F). Fusing - Class P ballasts do not require fusing. Fusing can be used when a single circuit has a large number of fixtures/ballasts. Grounding - ANSI C82.1 recommends all fixtures and ballasts be grounded. GE requires all electronic ballasts be grounded. Thermal Protection - All GE electronic ballasts meet UL 935 Standard for thermal protection. These ballasts are designated Class P. A Class P ballast will disconnect the ballast from input power in the event of internal over-temperature. Application Versatility Many GE models are designed to allow for applications with different types or quantities of lamps. Lamp applications not listed on label cannot be warranted. Audible Noise (Sound) Electrical equipment, including most fluorescent lamp ballasts, produces some noise. Care must be taken to select a ballast with the proper sound rating for a particular lighting installation. Secure mounting can reduce the potential for audible noise. Typically, electronic ballasts operate up to 75% quieter than electromagnetic ballasts for fluorescent lamps. Remote Mounting Excessive hot or cold temperatures, audible noise requirements, or a desire to operate lamps in more than one fixture with the same ballast (master/slave), may make it desirable to mount the ballast remotely. Care must be taken to allow for ballast heat dissipation and proper grounding. In any application, the wire used to extend leads must be at least as large as the wire supplied on the ballast (18 AWG) with an insulation rating of 1000 VAC at 90°C. Lead lengths in excess of those noted, cause loading effects that can dramatically impact ballast performance and void the warranty. GE T8 instant start and programmed (rapid) start electronic ballasts can be mounted remotely, from the lamp sockets, up to 18 feet. GE T8 rapid start electronic ballasts can be mounted remotely, from the lamp sockets, up to 12 feet. 1-12 transforming the power of light ™ Light Output Optimum light output from fluorescent lamps is achieved when the lamp wall is at 100-110°F. Any substantial excursion (either colder or warmer) will result in a reduction in light output. Ballast Life A fluorescent lamp ballast, like any other electrical device, generates heat during its normal operation. Ballast temperatures should be kept as low as possible. Maximum dissipation of heat through fixture design and proper ballast installation will help. Although excessive temperature may not cause the ballast to fail immediately, it can shorten ballast life. To assure maximum life, the ballast case temperature should not exceed 75°C, in a maximum ambient (fixture cavity) of 40°C. • Incorrect wiring • Poor heat dissipation due to surrounding insulation • Sealed (Vapor Tight) Fixtures - Unusual heat build-up due to lack of ventilation in fixtures may cause thermal (on/off) cycling of certain ballasts. Consult GE for specific recommendations. Recommendations: • Selection of a proper ballast to match the requirements of the lamp, fixture, voltage and installation • Mounting of ballast within the fixture with as much surface contact as possible between the ballast and metal portions of the fixture.Secure mounting will aid in proper heat dissipation and can minimize the potential for ballast hum. • The use of heat-conducting dissipators (radiators), if necessary, which increases surface contact between the ballast and fixture. • If necessary, locate the ballast in a remote, cooler area outside the fixture. • Consult GE for remote mounting recommendations. APPLICATION AND OPERATING INFORMATION ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS Starting Method Legend IS=Instant Start PRS=Programmed Rapid Start RS=Rapid Start PAR-IS=Parallel Instant Start PAR-PRS=Parallel Programmed Rapid Start PAR-RS=Parallel Rapid Start SER-RS=Series Rapid Start Causes of ballast overheating: • Incorrect line voltage or frequency • Incorrect size, type or number of lamps For more information, visit www.gelighting.com 1-13 ELECTRONIC FLUORESCENT BALLASTS TYPICAL SPECIFICATIONS FOR ULTRAMAX MULTI-VOLTAGE, INSTANT START, HIGH EFFICIENCY BALLASTS TYPICAL SPECIFICATIONS 1.1 1.2 1.3 Section I – Physical Characteristics The electronic ballast shall be physically interchangeable with standard electromagnetic and standard electronic ballast. The electronic ballast shall have a maximum height of 1.2 in. and maximum weight of 1.5 lbs. (except 4H). The electronic ballast shall be furnished with integral leads, color-coded to ANSI C82.11. Section II – Performance Requirements The electronic ballast shall operate throughout wide range of input line voltage 120-277 Volts, with +/-10% variation tolerance 50/60 Hz for Multi Voltage Control /Universal Voltage. 2.2 Ballast shall be classified “hi-efficiency” and shall provide a minimum of 3 watts energy savings over comparable standard electronic ballasts. 2.3 The electronic ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when used with the primary lamp at 120 Volts. It shall be less than 20% on other approved lamps. 2.4 The electronic ballast shall have a Power Factor greater than 98% when used with primary lamp at 120 Volts and greater than 95% at 277 Volts. 2.5 The electronic ballast shall be Sound Rated A. 2.6 The electronic ballast output frequency to the lamps shall be above 60 kHz to minimize interference with infrared control systems and eliminate visible flicker. 2.7 The electronic ballast shall meet ANSI C82.11 for Electronic Ballast Performance. 2.8 The electronic ballast shall withstand transients specified in ANSI C62.41, Location Category A3. 2.9 The electronic ballast shall be Instant Start with independent parallel lamp operation. 2.10 The electronic ballast shall have a Lamp Current Crest Factor of <1.5. 2.11 Lamps may be remote or tandem mounted up to a maximum of 18ft. overall lead length between ballasts and lamps. 2.12 Ballast shall have a minimum starting temperature of 0ºF for F32T8, F25T8 and F17T8. 3.1 3.2 3.3 3.4 2.1 1-14 4.1 4.2 4.3 4.4 4.5 4.6 Section III – Regulatory The electronic ballast shall meet the requirements of the Federal Communications Commission rules and regulations, Title 47 CFR part 18, for NonConsumer equipment. The electronic ballast shall comply with all applicable state and federal efficiency standards. The electronic ballast shall be Underwriters Laboratories (UL) Listed Class P & Type HL. The electronic ballast shall provide UL Class CC, Closed Cabinet protection to prevent ignition of non-UL–controlled thermoplastic diffuser and overheating of bi-pin lampholders. Section IV – Other The electronic ballast shall not contain Polychlorinated Biphenyl (PCBs). The electronic ballast shall carry a five year warranty form the date of manufacture. Warranty shall be valid for maximum case temperature of 70ºC. The electronic ballast shall eliminate lamp striation (spiraling effect). The electronic ballast shall be available in 1, 2, 3, & 4 lamp versions for F32T8 and 1 & 2 lamp versions for F96T8. The F32T8 electronic ballast shall be available with Ballast Factor of .77 Low, .87 Normal, and 1.15 High Power. The electronic ballast shall have constant Ballast Factor if one or more lamps fail. transforming the power of light ™ TYPICAL SPECIFICATIONS FOR INSTANT START BALLASTS FOR: • RH (Reduced Harmonics) • L (Low Wattage) • RHH (Reduced Harmonics High Light) 1. Ballasts (1-4 lamp) shall operate as a Parallel Circuit, allowing remaining lamp(s) to maintain full light output if one or more lamps fail. 2. Ballasts shall operate from 60 Hz input source of 120, 277 Volts, and sustained variations of ±10% (Voltage & Frequency) with no damage to the ballasts. 3. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz. 4. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. 5. Ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage. 6. Ballasts shall comply with FCC Part 18 NonConsumer Equipment for EMI (power line conducted) and RFI (Radiated). 7. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2. 8. Ballasts shall operate lamps with no visible flicker (< 3% flicker index). 9. Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage. 10. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. 11. Ballast shall have a Ballast Factor greater than .85 per ANSI C82.11-1993. Ballast Factor for Low Power (L) models shall be greater than .77. 12. Input current Total Harmonic Distortion shall not exceed 20% for the primary lamp applications. 13. Ballasts shall have a Power Factor greater than .95 for primary lamp applications. 14. The ballasts do not contain any PCBs. 15. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of manufacture. 16. Ballast shall be manufactured in an ISO 9001 Certified Facility. 17. Ballasts shall provide instant starting sequence consistent with ANSI standard C82.11-1993. 18. GE model __________________ (or approved equal). TYPICAL SPECIFICATIONS FOR INSTANT START BALLASTS FOR: Universal Voltage Performance • HP (High Performance) 1. Ballasts (1-4 lamp) shall operate as a Parallel Circuit, allowing remaining lamp(s) to maintain full light output if one or more lamps fail. 2. Ballasts shall operate from 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ±10% (Voltage & Frequency) with no damage to the ballasts. 3. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 42 kHz to minimize interference with infrared control systems. 4. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.111993. 5. Ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage. 6. Ballasts shall comply with FCC Part 18 NonConsumer Equipment for EMI (power line conducted) and RFI (Radiated). 7. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2. 8. Ballasts shall operate lamps with no visible flicker (<3% flicker index). 9. Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage. 10. Ballasts shall be Underwriters Laboratory UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. 11. Ballast shall have a Ballast Factor greater than .85 per ANSI C82.11-1993. 12. Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp. 13. Ballasts shall have a Power Factor greater than .98 for primary lamp. 14. The ballasts shall not have any PCBs. 15. The manufacturer shall provide written warranty against defects in material or workmanship,including replacement, for five years from date of manufacture. 16. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years. 17. Ballast shall be manufactured in an ISO 9001 Certified Facility. 18. Ballasts shall provide instant starting sequence consistent with ANSI standard C82.11-1993. 19. Ballast shall be Bx32IUNVHP-B (x=1 or 2) or Bx32IUNVHP-A (x=3 or 4) depending upon the quantity of lamps per fixture. 20. GE model ______________ (or approved equal). For more information, visit www.gelighting.com TYPICAL SPECIFICATIONS ELECTRONIC FLUORESCENT BALLASTS 1-15 TYPICAL SPECIFICATIONS TYPICAL SPECIFICATIONS FOR INSTANT START BALLASTS FOR: • HP (High Performance) • HPL (High Performance Low Power) • HPH (High Performance High Light) 1-16 1. Ballasts (1-4 lamp) shall operate as a Parallel Circuit, allowing remaining lamp(s) to maintain full light output if one or more lamps fail (except T12 High Output). 2. Ballasts shall operate from 50/60 Hz input source of 120, 277, and 347 Volts, and sustained variations of 10% (Voltage & Frequency) with no damage to the ballasts. 3. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz. 4. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. 5. Ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage. Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (Radiated). 6. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2. 7. Ballasts shall operate lamps with no visible flicker (< 3% flicker index). 8. Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage. 9. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. 10. Ballast shall have a Ballast Factor greater than .85 per ANSI C82.11-1993. Ballast Factor for Low Power (L) models shall be greater than .77. 11. Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp. 12. Ballasts shall have a Power Factor greater than .98 for primary lamp. 13. The ballasts do not contain any PCBs. 14. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of manufacture. 15. Ballast shall be manufactured in an ISO 9001 Certified Facility. 16. Ballasts shall provide instant starting sequence consistent with ANSI standard C82.11-1993. 17. GE model__________________(or approved equal). TYPICAL SPECIFICATIONS FOR RAPID START BALLASTS TYPICAL SPECIFICATIONS FOR PROGRAMMED (RAPID) START BALLASTS TYPICAL SPECIFICATIONS FOR T5 AND T5 HIGH OUTPUT (HO) BALLASTS 1. Ballasts (1-4 lamp) shall operate as a Parallel Circuit, allowing remaining lamp(s) to maintain full light output if one or more lamps fail (except T12 High Output). 2. Ballasts shall operate from 60 Hz input source of 120, 277 Volts, and sustained variations of ±10% (Voltage & Frequency) with no damage to the ballasts. 3. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz. 4. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. 5. Ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage. 6. Ballasts shall comply with FCC Part 18 NonConsumer Equipment for EMI (power line conducted) and RFI (Radiated). 7. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2. 8. Ballasts shall operate lamps with no visible flicker (< 3% flicker index). 9. Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage. 10. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. 11. Ballast shall have a Ballast Factor greater than .85 per ANSI C82.11-1993. 12. Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp applications. 13. Ballast shall be manufactured in an ISO 9001 Certified Facility. 14. Ballasts shall have a Power Factor greater than .98 primary applications. 15. The ballasts do not contain any PCBs. 16. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of manufacture. 17. Ballasts shall provide rapid starting sequence consistent with ANSI standard C82.11-1993. 18. GE model_________________ (or approved equal). 1. Ballasts shall have a minimum start temperature of 0°F. 2. Ballasts shall operate from a 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ±10% (Voltage & Frequency) with no damage to the ballasts. 3. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 42 kHz to minimize interference with infrared control systems. 4. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. 5. Ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage. 6. Ballasts shall comply with FCC Part 18 NonConsumer Equipment for EMI (power line conducted) and RFI (Radiated). 7. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2. 8. Ballasts shall operate lamps with no visible flicker (<3% flicker index). 9. Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage. 10. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. 11. Ballast shall have a Ballast Factor greater than .85, per ANSI C82.11-1993. 12. Input current Total Harmonic Distortion shall not exceed 10%. 13. Ballasts shall have a Power Factor greater than .98, for primary application. 14. The ballasts shall not have any PCBs. 15. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of manufacture. 16. Ballast shall be manufactured in an ISO 9001 Certified Facility. 17. Ballast shall be manufactured in North America. 18. Ballast shall be GE AccuStart HP Product Bx32PUNVHP-A (x=1,2,3, or 4). 19. GE model ______________ (or approved equal). 1. Ballast shall be Programmed Rapid Start. 2. Ballast shall incorporate lamp shutdown circuitry for end of lamp life protection. 3. Ballast shall allow for re-lamping without the need to cycle power. 4. Ballasts shall operate from 50/60 Hz input source of 108-305 Volts, with no damage to the ballasts. 5. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz. 6. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. 7. Ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage. 8. Ballasts shall comply with FCC Part 18 NonConsumer Equipment for EMI (power line conducted) and RFI (Radiated). 9. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2. 10. Ballasts shall operate lamps with no visible flicker (< 3% flicker index). 11. Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage. 12. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. 13. Ballast shall have a Ballast Factor greater than .95 per ANSI C82.11-1993. 14. Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp. 15. Ballasts shall have a Power Factor greater than .98. 16. The ballasts do not contain any PCBs. 17. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of manufacture. 18. Ballast shall be manufactured in and ISO 9001 Certified Facility. 19. GE model ________________ (or approved equal). transforming the power of light ™ For more information, visit www.gelighting.com TYPICAL SPECIFICATIONS ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS 1-17 ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS 1-18 0.77 49709 GE-432-MAX-L/Ultra Multi-Volt 1 N 0.87 49771 GE-132-MAX-N/Ultra Multi-Volt 2 N 0.87 49772 GE-232-MAX-N/Ultra Multi-Volt 3 N 0.87 49773 GE-332-MAX-N/Ultra Multi-Volt 4 N 0.87 49774 GE-432-MAX-N/Ultra Multi-Volt 2 H 1.15 49775 GE-232-MAX-H/Ultra Multi-Volt 3 H 1.15 49776 GE-332-MAX-H/Ultra Multi-Volt 4 H 1.15 49777 GE-432-MAX-H/Ultra Multi-Volt 1 N 0.88 47532 B132PUNVHP-A Multi-Volt 2 N 0.88 47533 B232PUNVHP-A Multi-Volt 3 N 0.88 41008 B332PUNVHP-B Multi-Volt 4 N 0.88 41009 B432PUNVHP-B Multi-Volt N 0.88 3 N 0.88 80355 80356 80357 80358 B232SR120V5 B232SR277V5 B332SR120V5 B332SR277V5 N 0.87 49766 GE-159-MAX-N/Ultra Multi-Volt 2 N 0.87 49767 GE-259-MAX-N/Ultra Multi-Volt 2 H 1.15 TBA GE-259-MAX-H/Ultra Multi-Volt 1 N 0.93 2 N 0.88 80286 80287 80286 80287 B286I120RH B286I277RH B286I120RH B286I277RH Standard Standard Standard Standard High Program Rapid Start Dimming 120 277 120 277 120 277 120 277 B132I120RH-A B132I277RH-A B232I120RH-A B232I277RH-A B332I120RH-A B332I277RH-A B432I120RH-A B432I277RH-A 120 277 120 277 120 277 B232I120RHH B232I277RHH B332I120RHH B332I277RHH B232I120HPH B232I277HPH 120 277 120 277 120 277 120 277 B132P120RH B132P277RH B232P120RH B232P277RH B332P120RH B332P277RH B432P120RH B432P277RH B132PUNVHP-A B232IUNVHP-B B332IUNVHP-A B432IUNVHP-A 120 277 120 277 B159I120RH B159I277RH B259I120RH B259I277RH 120 277 B232I120RHH B232I277RHH 120 277 120 277 B286I120RH B286I277RH B286I120RH B286I277RH REL-2P32-HL-SC VEL-2P32-HL-SC REL-3P32-HL-SC VEL-3P32-HL-SC B332PUNVHP-B B432PUNVHP-B B259IUNVHP B232I120HPH B232I277HPH transforming the power of light ™ 3-level switch dim B232SR120S30 B232SR277S30 B332SR120S30 B332SR277S30 B259I120HE/Ultra B259I277HE/Ultra REL-2P59-S-RH-TP VEL-2P59-S-RH-TP REL-2P59-S-RH-TP VEL-2P59-S-RH-TP RCN-1S32-SC VCN-1S32-SC RCN-2S32-SC VCN-2S32-SC RCN-3S32-SC VCN-3S32-SC RCN-4S32-SC VCN-4S32-SC QTP1x32T8/120 PSN-F QTP1x32T8/277 PSN-F QTP2x32T8/120 PSN-F QTP2x32T8/277 PSN-F QTP3x32T8/120 PSN-SC QTP3x32T8/277 PSN-SC QTP4x32T8/120 PSN-SC QTP4x32T8/277 PSN-SC RZT-2S32 VZT-2S32 RZT-3S32 VZT-3S32 QT2x32/120DIM5-B QT2x32/277DIM5-B QT3x32/120DIM5-Q QT3x32/277DIM5-Q RCN-2P59 VCN-2P59 RCN-2P59 VCN-2P59 QT2x59/120IS QT2x59/277IS QT2x59/120PLUS QT2X59/277PLUS RCN-2S86 VCN-2S86 RCN-2S86 VCN-2S86 QTP2x59T8/120 ISN-A QTP2x59T8/277 ISN-A Lamp QTP1x32T8/120 ISN-D QTP1x32T8/277 ISN-D QTP2x32T8/120 ISN-D QTP2x32T8/277 ISN-D QTP3x32T8/120 ISN-A QTP3x32T8/277 ISN-A QTP4x32T8/120 ISN-A QTP4x32T8/277 ISN-A QT2x32/120PLUS QT2x32/277PLUS QT3x32/120PLUS QT3x32/277PLUS REL-2P59-HL VEL-2P59-HL REL-2S86 series RS VEL-2S86 series RS QT1x32/120IS-SC QT1x32/277IS-SC QT2x32/120IS-SC QT2x32/277IS-SC QT3x32/120ISN-SC QT3x32/277ISN-SC QT4x32/120ISN-SC QT4x32/277ISN-SC Starting ROP-2P32-SC VOP-2P32-SC ROP-2P32-SC VOP-2P32-SC ROP-2P32-SC VOP-2P32-SC ROP-2P32-SC VOP-2P32-SC Power RCN-1P32-SC VCN-1P32-SC RCN-2P32-SC VCN-2P32-SC RCN-3P32-SC VCN-3P32-SC RCN-4P32-SC VCN-4P32-SC B232PUNVHP-A Varible dimming B232SR120V5 B232SR277V5 B332SR120V5 B332SR277V5 120 277 120 277 B232I120HE/Ultra B232I277HE/Ultra B332I120HE/Ultra B332I277HE/Ultra B432I120HE/Ultra B432I277HE/Ultra REL-1P32-SC VEL-1P32-SC REL-2P32-SC VEL-2P32-SC REL-3P32-SC VEL-3P32-SC REL-4P32-SC VEL-4P32-SC B132IUNVHP-B BALLAST MATRIX L Four-Foot T8, F32, F32/U, F25, F17, F32WM 4 8-Ft. T8 F96 Multi-Volt 8-Ft. HO GE-332-MAX-L/Ultra Instant Start 49708 QT2x32/120LP QT2x32/277LP QT3x32/120LP QT3x32/277LP QT4x32/120LP QT4x32/277LP Program Rapid Start 0.77 RCN-2P32-LW VCN-2P32-LW RCN-3P32-LW VCN-3P32-LW RCN-4P32-LW VCN-4P32-LW Dimming L B232I120EL/Ultra B232I277EL/Ultra B332I120EL/Ultra B332I277EL/Ultra B432I120EL/Ultra B432I277EL/Ultra Instant Start 3 B232I120L-A B232I277L-A B332I120L-A B332I277L-A B432I120L-A B432I277L-A IS-vs-RS Multi-Volt Low Power GE-232-MAX-L/Ultra Standard 49707 QT PRO QTP1x32T8/120 RSL-A QTP1x32T8/277 RSL-A QTP2x32T8/120 RSL-A QTP2x32T8/277 RSL-A QTP3x32T8/120 RSL-A QTP3x32T8/277 RSL-A QTP4x32T8/120 RSL-A QTP4x32T8/277 RSL-A High 0.77 Std. Quicktronic Standard L High Efficiency ROP-2P32-LW-SC VOP-2P32-LW-SC ROP-2P32-LW-SC VOP-2P32-LW-SC ROP-2P32-LW-SC VOP-2P32-LW-SC ROP-2P32-LW-SC VOP-2P32-LW-SC Standard 2 Sylvania Std. Discrete REL-1P32-LW-SC VEL-1P32-LW-SC REL-2P32-LW-SC VEL-2P32-LW-SC REL-3P32-LW-SC VEL-3P32-LW-SC REL-4P32-LW-SC VEL-4P32-LW-SC Standard Multi-Volt 120 277 120 277 120 277 120 277 Advance Centium High GE-132-MAX-L/Ultra GE/Universal Ltg. Technologies (Magnetek) Std. RH HP High Efficiency Standard # Lamps Power 49706 Low Power 0.77 High Instant Start Description GE Ballast Cross Reference for T8 Lamps GE Ballast Cross Reference for T8 Lamps Input Voltage L 1 Instant Start Product Code 1 2 IS-(vs-Rs) GE Electronic Ballasts Ballast Factor Standard Starting Lamp 8-Ft. HO 8-Ft. T8 F96 Four-Foot T8, F32, F32/U, F25, F17, F32WM BALLAST MATRIX BALLAST MATRIX For more information, visit www.gelighting.com 1-19 ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS F17T8 GE Lamp Certification Line Input Power Ballast Product Code Catalog Starting Line UL Type UL Type Current Power Factor Factor C US (C Pack) Qty. Method Volts Number (Amps) (Watts) (PF) (BF) CC HL F17T8 - One Lamp Applications 120 0.14 >.99 1.05 49771 1 IS GE-132-MAX-N/Ultra • • • 17 277 0.07 >.90 1.05 47532 1 PRS 120 277 0.15 0.07 B132PUNVHP-A • GE-232-MAX-L/Ultra • • • GE-232-MAX-N/Ultra • • • B232PUNVHP-A • 17 >.99 >.96 0.91 THD % Min. F/C Start Temp Wiring Diag. Dim. <10 <22 0/-18 1A -A <10 <15 0/-18 2 -A 0/-18 1B -A 0/-18 1B -A 0/-18 30 -A GE Lamp Product Code Starting Line Catalog C (C Pack) Qty. Method Volts Number F25T8 - One Lamp Applications 120 49706 GE-132-MAX-L/Ultra 277 1 IS 120 49771 GE-132-MAX-N/Ultra 277 120 47532 1 PRS B132PUNVHP-A 277 F25T8 - Two Lamp Applications 120 49707 GE-232-MAX-L/Ultra 277 2 PAR-IS 120 49772 GE-232-MAX-N/Ultra 277 F17T8 - Two Lamp Applications 49707 2 PAR-IS 49772 47533 2 SER-PRS 120 277 120 277 120 277 0.24 0.11 0.27 0.12 0.28 0.13 28 29 32 34 >.99 >.93 >.99 >.94 >.99 >.95 .95 1.05 0.95 <12 <24 <10 <20 <10 <15 F17T8 - Three Lamp Applications 49708 3 PAR-IS 49773 41008 120 277 120 277 3 SER-PRS GE-332-MAX-L/Ultra • • • GE-332-MAX-N/Ultra • • • B332PUNVHP-A • 120 277 0.35 0.16 0.40 0.18 0.40 0.19 42 48 48 >.99 >.96 >.99 >.97 >.98 >.90 0.95 1.05 0.92 <10 <19 <10 <17 <10 47533 0/-18 1C -A 0/-18 1C -A 49708 0/-18 23 -A 49773 4 PAR-IS 49774 120 277 120 277 GE-432-MAX-L/Ultra • • • GE-432-MAX-N/Ultra • • • B432PUNV-HP-B • 120 41009 4 SER-PRS 277 65 64 >.99 >.96 >.99 >.97 0.57 67 >.90 0.92 0.24 67 >.90 0.92 0.95 1.05 <10 <19 <10 <18 41008 3 SER-PRS 1D -A 0/-18 1D -A 49709 <25 0/-18 8 ST 49774 4 PAR-IS <25 0/-18 8 ST 41009 4 SER-PRS 120 277 • • • • • 0.18 0.08 0.24 0.09 0.20 0.09 • • • • • • • B232PUNVHP-A • GE-332-MAX-L/Ultra • • • GE-332-MAX-N/Ultra • • • B332I347HP • B332PUNVHP-A • GE-432-MAX-L/Ultra • • • GE-432-MAX-N/Ultra • • • B432PUNVHP-A • 21 23 24 24 >.99 >.92 >.99 >.93 >.99 >.98 0.34 0.15 0.21 0.38 53 45 >.99 >.96 >.96 >.99 0.40 0.17 47 46 >.99 >.97 0.50 0.22 0.56 0.24 0.20 0.77 0.33 60 59 67 66 68 92 89 >.99 >.97 >.99 >.98 >.99 >.99 >.95 0.67 0.30 0.76 0.33 80 79 91 89 >.99 >.97 >.99 >.98 0.77 0.33 92 89 >.99 >.95 40 0.94 0.94 <10 <20 <10 Min. F/C Start Temp Wiring Diag. Dim. 0/-18 1A -A 0/-18 1A -A 0/-18 2 -A 0/-18 1B -A 0/-18 1B -A 0/-18 30 -A 0/-18 1C -A 0/-18 1C -A 0/-18 6 ST 0/-18 8 -A 0/-18 1D -A 0/-18 1D -A 0/-18 8 -A <18 0.91 <10 0.87 0.94 <10 <19 <15 <10 0.94 <10 0.84 120 277 120 277 347 120 277 0.91 <10 <14 <10 <13 <10 .89 <10 0.84 0.94 F25T8 - Four Lamp Applications 120 277 120 277 120 277 0.84 0.94 0.89 <10 <15 <10 <14 <10 DIMENSIONS STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W ST -A -B 1-20 PAR-IS 0/-18 DIMENSIONS IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start 3 80136 0.47 0.21 0.54 0.24 56 SER-PRS • THD % F25T8 - Three Lamp Applications F17T8 - Four Lamp Applications 49709 2 Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor (Amps) (Watts) (PF) (BF) CC HL US F25T8 FOR (1), (2), (3) & (4) F25T8 LAMPS FOR (1), (2), (3) & (4) F17T8 LAMPS 9.50” 9.50” 9.50” 2.40” 1.70” 1.50” transforming the power of light ™ IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Mounting Dimension H M X 1.55” 1.18” 1.00” 8.89” 8.89” 8.89” 1.69” 1.69” 0.88” STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W ST -A -B 9.50” 9.50” 9.50” 2.40” 1.70” 1.50” Mounting Dimension H M X 1.55” 1.18” 1.00” 8.89” 8.89” 8.89” 1.69” 1.69” 0.88” For more information, visit www.gelighting.com 1-21 ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F28T8 - One Lamp Applications 120 49706 277 1 IS 120 49771 277 F28T8 - Two Lamp Applications 120 49707 277 120 49772 2 PAR-IS 277 120 49775 277 F28T8 - Three Lamp Applications 120 49708 277 120 49773 277 3 PAR-IS 120 49776 277 F28T8 - Four Lamp Applications 120 49709 277 120 49774 4 PAR-IS 277 120 49777 277 Catalog Number Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C FOR (1) F32T8 LAMP THD % Min. F/C Start Temp Wiring Diag. Dim. GE-132-MAX-L/Ultra • • • TBD 22 TBD TBD TBD TBD 1A -A GE-132-MAX-N/Ultra • • • TBD 25 TBD TBD TBD TBD 1B -A GE-232-MAX-L/Ultra • • • TBD GE-232-MAX-N/Ultra • • • TBD GE-232-MAX-H/Ultra • • • TBD GE-332-MAX-L/Ultra • • • TBD GE-332-MAX-N/Ultra • • • TBD GE-332-MAX-H/Ultra • • • TBD GE-432-MAX-L/Ultra • • • TBD GE-432-MAX-N/Ultra • • • TBD GE-432-MAX-H/Ultra • • • TBD 44 49 48 66 65 65 72 71 97 96 87 86 98 96 133 131 GE Lamp Product Code Starting Line Catalog C (C Pack) Qty. Method Volts Number F32T8 - One Lamp Applications 120 49706 GE-132-MAX-L/Ultra 277 120 49771 GE-132-MAX-N/Ultra 277 1 IS 120 49707 GE-232-MAX-L/Ultra 277 120 49772 GE-232-MAX-N/Ultra 277 TBD TBD TBD TBD 1B -A TBD TBD TBD TBD 1B -A TBD TBD TBD TBD 1B -A TBD TBD TBD TBD 1C -A TBD TBD TBD TBD 1C -A TBD TBD TBD TBD 1C -A 47532 1 • • • • • • • • • • • B132PUNVHP-A • B232PUNVHP-A • 0.22 0.10 0.42 0.19 0.24 0.11 0.26 0.12 0.26 0.11 0.27 0.12 25 28 28 29 31 31 30 32 >.99 >.94 >.99 >.98 >.99 >.93 >.99 >.94 >.99 >.98 >.99 >.95 0.77 0.87 0.87 0.87 <10 <18 <10 <15 <10 <23 <10 <20 Min. F/C Start Temp Wiring Diag. Dim. 0/-18 1A -A 0/-18 1A -A 0/-18 1B -A 0/-18 1B -A 0.88 <10 0/-18 2 -A 1.00 <10 <15 0/-18 30 -A TBD TBD TBD TBD 1D -A TBD TBD TBD TBD 1D -A TBD TBD TBD TBD TBD ST GE Lamp Certification Line Input Power Ballast Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor C US (C Pack) Qty. Method Volts Number (Amps) (Watts) (PF) (BF) CC HL F32T8/WM - One Lamp Applications 120 0.21 >.99 49706 GE-132-MAX-L/Ultra • • • 24 0.77 277 0.09 >.93 120 0.22 26 >.99 49707 GE-232-MAX-L/Ultra • • • 0.87 1 IS 277 0.11 27 >.93 120 0.25 >.99 49772 GE-232-MAX-N/Ultra • • • 29 0.87 277 0.12 >.94 1 SER-PRS 120 277 B132PUNVHP-A • 0.23 0.10 28 >.99 >.98 0.88 THD % <10 <18 <11 <25 <10 <21 <10 Min. F/C Start Wiring Temp Diag. Dim. 0/-18 1A -A 0/-18 1B -A 0/-18 1B -A 60/16 2 -A DIMENSIONS DIMENSIONS STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start ST -A -B IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W 1-22 • THD % FOR (1) F32T8/WM LAMP 47532 IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start PRS 47533 120 277 120 277 Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL F32T8 & F32T8/WM F28T8 FOR (1), (2), (3) & (4) F28T8 LAMPS (F28T8/UMX – GE ULTRAMAX SYSTEM) 9.50” 9.50” 9.50” 2.40” 1.70” 1.50” transforming the power of light ™ Mounting Dimension H M X 1.55” 1.18” 1.00” 8.89” 8.89” 8.89” 1.69” 1.69” 0.88” STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W ST -A -B 9.50” 9.50” 9.50” 2.40” 1.70” 1.50” Mounting Dimension H M X 1.55” 1.18” 1.00” 8.89” 8.89” 8.89” 1.69” 1.69” 0.88” For more information, visit www.gelighting.com 1-23 ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS GE Lamp Product Code Starting Line Catalog C (C Pack) Qty. Method Volts Number F32T8 - Two Lamp Applications 120 49707 GE-232-MAX-L/Ultra 277 120 49772 GE-232-MAX-N/Ultra 277 120 49775 GE-232-MAX-H/Ultra 2 PAR-IS 277 120 49708 GE-332-MAX-L/Ultra 277 120 49773 GE-332-MAX-N/Ultra 277 47533 2 SER-PRS 120 277 B232PUNVHP-A FOR (2) F32T8/WM LAMPS Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL • • • • • • • • • • • • • • • • 0.42 0.19 0.47 0.21 0.84 0.37 0.45 0.20 0.49 0.22 0.52 0.22 48 54 53 74 73 53 58 62 60 >.99 >.97 >.99 >.96 >.99 >.98 >.99 >.97 >.99 >.97 >.99 >.98 0.77 0.87 1.15 0.87 0.87 0.88 THD % Min. F/C Start Temp <10 <17 <10 <15 <10 <13 <10 <16 <10 <14 <10 Wiring Diag. Dim. 0/-18 1B -A 0/-18 1B -A 0/-18 1B -A 0/-18 1C -A 0/-18 1C -A 0/-18 30 -A GE Lamp Product Code Starting Line Catalog C (C Pack) Qty. Method Volts Number F32T8/WM - Two Lamp Applications 120 49707 GE-232-MAX-L/Ultra 277 120 49772 GE-232-MAX-N/Ultra 277 2 PAR-IS 120 49708 GE-332-MAX-L/Ultra 277 120 49773 GE-332-MAX-N/Ultra 277 47533 STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start 120 277 B232PUNVHP-A ST -A 9.50” 9.50” IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W 1-24 SER-PRS • • • • • • • • • • • • • 0.40 0.18 0.45 0.20 0.42 0.19 0.46 0.21 0.50 0.21 >.99 >.97 >.99 >.96 >.99 >.97 >.99 >.97 46 53 52 49 55 >.99 >.98 60 0.77 0.87 0.87 0.87 0.88 THD % Min. F/C Start Temp Wiring Diag. Dim. 0/-18 1B -A 0/-18 1B -A 0/-18 1C -A 0/-18 1C -A 60/16 30 -A <10 <17 <10 <15 <10 <17 <10 <15 <10 DIMENSIONS DIMENSIONS IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start 2 Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL F32T8 & F32T8/WM F32T8 FOR (2) F32T8 LAMPS 2.40” 1.70” Mounting Dimensions H M X 1.55” 1.18” transforming the power of light ™ 8.89” 8.89” 1.69” 1.69” STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W ST -A 9.50” 9.50” 2.40” 1.70” Mounting Dimensions H M X 1.55” 1.18” 8.89” 8.89” 1.69” 1.69” For more information, visit www.gelighting.com 1-25 ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F32T8 - Three Lamp Applications 120 49708 277 120 49773 277 120 49776 277 120 49709 3 PAR-IS 277 120 49774 277 120 49777 277 80136 347 120 41008 3 SER-RS 277 41009 3 SER-PRS 120 277 Catalog Number FOR (4) F32T8 LAMPS Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C GE-332-MAX-L/Ultra • • • GE-332-MAX-N/Ultra • • • GE-332-MAX-H/Ultra • • • GE-432-MAX-L/Ultra • • • GE-432-MAX-N/Ultra • • • GE-432-MAX-H/Ultra B332I347HP • B332PUNVHP-A* • B432PUNVHP-A • 0.63 0.27 0.70 0.30 0.92 0.40 0.65 0.29 0.72 0.32 73 72 82 80 111 109 78 77 85 84 >.99 >.98 >.99 >.98 >.99 >.98 >.99 >.97 >.99 0.87 TBD TBD TBD 0.25 0.77 0.34 88 92 90 >.99 >.99 >.95 0.77 0.34 92 90 >.99 >.98 0.77 0.87 1.15 0.87 THD % Min. F/C Start Temp <10 <13 <10 <13 <10 <13 <13 <16 Wiring Diag. Dim. 0/-18 1C -A 0/-18 1C -A 0/-18 1C -A 0/-18 1D -A <13 0/-18 1D -A TBD TBD TBD TBD TBD 0.88 <10 0/-18 6 ST 0.88 <10 0/-18 23 -A 0.93 <10 0/-18 23 -A GE Lamp Certification Line Input Power Ballast Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor C US (C Pack) Qty. Method Volts Number (Amps) (Watts) (PF) (BF) CC HL F32T8 - Four Lamp Applications 120 0.84 97 >.99 49709 GE-432-MAX-L/Ultra • • • 0.77 277 0.37 96 >.98 120 0.94 109 >.99 49774 GE-432-MAX-N/Ultra • • • 0.87 277 0.40 107 >.98 4 PAR-IS 41009 • • • • • • • • • • • 0.60 0.26 0.66 0.29 0.89 0.39 0.25 0.73 0.32 69 68 78 77 106 104 88 87 85 >.99 >.98 >.99 >.98 >.99 >.98 >.99 >.99 >.95 THD % 0.88 <10 <13 <10 <13 <10 <13 <10 0.88 <10 0.77 0.87 1.15 Min. F/C Start Temp Wiring Diag. Dim. 0/-18 1C -A 0/-18 1C -A 0/-18 1C -A 0/-18 6 ST 0/-18 23 -A SER-PRS 120 277 B432PUNVHP-A • TBD 1.00 0.42 • 151 147 119 115 Wiring Diag. Dim. 0/-18 1D -A 0/-18 1D -A TBD TBD TBD TBD TBD TBD >.99 >.95 0.88 <10 0/-18 8 -A THD % Min. F/C Start Temp Wiring Diag. Dim. 0/-18 1D -A 0/-18 1D -A TBD TBD TBD TBD <10 0/-18 8 -A GE Lamp Certification Line Input Power Ballast Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor C US (C Pack) Qty. Method Volts Number (Amps) (Watts) (PF) (BF) CC HL F32T8/WM - Four Lamp Applications 120 0.80 92 >.99 49709 GE-432-MAX-L/Ultra • • • 0.77 277 0.36 91 >.98 120 0.90 105 >.99 49774 4 PAR-IS GE-432-MAX-N/Ultra • • • 0.87 277 0.39 103 >.98 120 145 49777 GE-432-MAX-H/Ultra* • • • TBD TBD TBD 277 141 FOR (3) F32T8/WM LAMPS Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL 4 • <10 <13 <10 <13 Min. F/C Start Temp FOR (4) F32T8/WM LAMPS * Preliminary performance data GE Lamp Product Code Starting Line Catalog C (C Pack) Qty. Method Volts Number F32T8/WM - Three Lamp Applications 120 49708 GE-332-MAX-L/Ultra 277 120 49773 GE-332-MAX-N/Ultra 277 3 PAR-IS 120 49776 GE-332-MAX-H/Ultra 277 80136 347 B332I347HP 120 41008 3 SER-PRS B332PUNVHP-A* 277 120 GE-432-MAX-H/Ultra* • 277 49777 THD % F32T8 & F32T8/WM F32T8 & F32T8/WM FOR (3) F32T8 LAMPS 41009 4 SER-PRS 120 277 B432PUNVHP-A* • 0.95 0.41 114 110 >.99 >.95 0.88 <10 <14 <10 <13 * Preliminary performance data * Preliminary performance data DIMENSIONS DIMENSIONS IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W ST -A 1-26 9.50” 9.50” 2.40” 1.70” IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Mounting Dimensions H M X 1.55” 1.18” transforming the power of light ™ 8.89” 8.89” 1.69” 1.69” STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W ST -A 9.50” 9.50” 2.40” 1.70” Mounting Dimension H M X 1.55” 1.18” 8.89” 8.89” 1.69” 1.69” For more information, visit www.gelighting.com 1-27 ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F40T8 - One Lamp Applications 120 49766 277 120 49767 1 IS 277 120 TBD 277 F40T8 - Two Lamp Applications 120 49767 277 120 49773 2 PAR-IS 277 120 49776 277 F40T8 - Three Lamp Applications 120 49774 277 3 PAR-IS 120 49777 277 Catalog Number FOR (1) AND (2) F96T8 LAMPS Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C 0.32 0.15 0.39 0.18 38 >.99 >.95 >.99 >.95 GE-159-MAX-N/Ultra • • • GE-259-MAX-N/Ultra • • • GE-132-MAX-N/Ultra • • • TBD TBD TBD TBD GE-259-MAX-N/Ultra • • • 0.66 0.29 77 76 >.97 0.94 46 0.94 0.94 THD % <10 <18 <10 <20 TBD <10 Min. F/C Start Temp Wiring Diag. Dim. 0/-18 1A -A 0/-18 1B -A TBD 1A -A 0/-18 1B -A GE Lamp Product Code Starting Line Catalog C (C Pack) Qty. Method Volts Number F96T8 - One Lamp Applications 120 49766 GE-159-MAX-N/Ultra 277 120 49767 GE-259-MAX-N/Ultra 277 1 IS 80142 120 B259I120HPL 80143 277 B259I277HPL F96T8 - Two Lamp Applications 120 49767 GE-259-MAX-N/Ultra 277 80148 120 B259I120RHH 80149 2 PAR-IS 277 B259I277RHH 80142 120 B259I120HPL 80143 277 B259I277HPL <18 GE-332-MAX-N/Ultra • • • TBD TBD TBD TBD TBD TBD 1B -A GE-332-MAX-H/Ultra • • • TBD TBD TBD TBD TBD TBD 1C -A GE-432-MAX-N/Ultra • • • TBD TBD TBD TBD TBD TBD 1C -A GE-432-MAX-H/Ultra • • • TBD TBD TBD TBD TBD TBD TBD ST Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL • • • • • • • • • • • • • • • 0.45 0.21 0.53 0.24 0.51 0.22 56 55 60 60 >.99 >.95 >.99 >.97 >.98 >.98 0.95 0.41 1.30 0.56 0.84 0.36 112 110 150 150 100 100 >.99 >.98 >.98 >.98 >.98 >.98 62 0.87 0.87 0.92 0.92 0.87 1.18 1.18 0.78 0.78 Wiring Diag. Dim. 0/-18 1A -A 0/-18 1B -A 50/10 50/10 14 14 ST ST <10 <15 <20 <20 <10 <10 0/-18 1B -A 32/0 32/0 50/10 50/10 14 14 14 14 SL SL ST ST THD % Min. F/C Start Temp Wiring Diag. Dim. <10 <15 0/-18 1A -A <10 <15 0/-18 1B -A DIMENSIONS DIMENSIONS STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start ST -A -B IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W 1-28 <10 <15 <10 <20 <10 <10 Min. F/C Start Temp FOR (1) AND (2) F96T8/WM LAMPS GE Lamp Certification Line Input Power Ballast Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor C US (C Pack) Qty. Method Volts Number (Amps) (Watts) (PF) (BF) CC HL F96T8/WM - One Lamp Applications 120 0.46 54 >.99 49766 GE-159-MAX-N/Ultra • • • 0.87 1 IS 277 0.20 53 >.95 F96T8/WM - Two Lamp Applications 120 0.90 107 >.99 49767 2 PAR-IS GE-259-MAX-N/Ultra • • • 0.87 277 0.39 105 >.98 IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start THD % T8 SLIMLINE F96T8 & F96T8/WM F40T8 FOR (1), (2) & (3) F40T8 LAMPS 9.50” 9.50” 9.50” 2.40” 1.70” 1.50” transforming the power of light ™ Mounting Dimension H M X 1.55” 1.18” 1.00” 8.89” 8.89” 8.89” 1.69” 1.69” 0.88” STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W ST SL -A 9.50” 11.75” 9.50” 2.40” 3.13” 1.70” Mounting Dimension H M X 1.55” 1.78” 1.18” 8.89” 11.41” 8.89” 1.69” 2.00” 1.69” For more information, visit www.gelighting.com 1-29 ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS T5 FOR F14, F21, F28 & F35T5 LAMPS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F48T8HO - One Lamp Applications 80286 120 1 IS 80287 277 F60T8HO - One Lamp Applications 80286 120 1 IS 80287 277 F72T8HO - One Lamp Applications 80286 120 1 IS 80287 277 F96T8HO - One Lamp Applications 80286 120 1 IS 80287 277 F48T8HO - Two Lamp Applications 80286 120 2 PAR-IS 80287 277 F60T8HO - Two Lamp Applications 80286 120 2 PAR-IS 80287 277 F72T8HO - Two Lamp Applications 80286 120 2 PAR-IS 80287 277 F96T8HO - Two Lamp Applications 80286 120 2 PAR-IS 80287 277 Catalog Number Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C THD % Min. F/C Start Temp Wiring Diag. Dim. B286I120RH B286I277RH • • • • 0.47 0.20 48 47 > .90 > .90 1.00 1.00 < 30 < 30 -20/-29 -20/-29 3 3 SL SL B286I120RH B286I277RH • • • • 0.56 0.23 60 57 > .90 > .90 0.99 0.98 < 30 < 30 -20/-29 -20/-29 3 3 SL SL B286I120RH B286I277RH • • • • 0.64 0.26 71 67 > .90 > .90 0.98 0.98 < 30 < 30 -20/-29 -20/-29 3 3 SL SL B286I120RH B286I277RH • • • • 0.79 0.32 92 87 > .90 > .90 0.96 0.93 < 25 < 25 -20/-29 -20/-29 3 3 SL SL B286I120RH B286I277RH • • • • 0.70 0.30 80 77 > .95 > .90 0.85 0.84 < 25 < 25 -20/-29 -20/-29 3 3 SL SL B286I120RH B286I277RH • • • • 0.85 0.36 99 96 > .95 > .95 0.85 0.84 < 20 < 20 -20/-29 -20/-29 3 3 SL SL B286I120RH B286I277RH • • • • 1.00 0.42 117 114 > .95 > .95 0.85 0.84 < 20 < 20 -20/-29 -20/-29 3 3 SL SL B286I120RH B286I277RH • • • • 1.30 0.53 151 144 > .95 > .95 0.81 0.81 < 20 < 20 -20/-29 -20/-29 3 3 SL SL GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F14T5 - One Lamp Applications 120 47536 1 PRS 277 F14T5 - Two Lamp Applications 120 47536 2 SER-PRS 277 F21T5 - One Lamp Applications 120 47536 1 PRS 277 F21T5 - Two Lamp Applications 120 47536 2 SER-PRS 277 F28T5 - One Lamp Applications 120 47536 1 PRS 277 F28T5 - Two Lamp Application 120 47536 2 SER-PRS 277 F35T5 - One Lamp Applications 120 47536 1 PRS 277 F35T5 - Two Lamp Applications 120 47536 2 SER-PRS 277 STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start C THD % Min. F/C Start Temp Wiring Diag. Dim. B228PUNV-C • 0.15 0.07 18 >.98 >.90 1.05 <10 <15 0/-18 4a -C B228PUNV-C • 0.28 0.13 34 >.98 >.95 1.00 <10 0/-18 4a -C B228PUNV-C • 0.21 0.10 25 >.98 >.95 1.03 <10 <15 0/-18 4a -C B228PUNV-C • 0.41 0.18 49 48 >.98 1.00 <10 0/-18 4a -C B228PUNV-C • 0.28 0.12 33 >.98 >.95 1.00 <10 0/-18 4a -C B228PUNV-C • 0.55 0.23 66 64 >.98 1.00 <10 0/-18 4a -C B228PUNV-C • 0.34 0.15 40 >.98 >.95 1.00 <10 0/-18 4a -C B228PUNV-C • 0.67 0.28 81 78 >.98 1.00 <10 0/-18 4a -C SL IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W 1-30 Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL DIMENSIONS DIMENSIONS IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Catalog Number T5 T8HO FOR (1) & (2) F48T8HO, F60T8HO, F72T8HO & F96T8HO LAMPS 11.75” 3.13” transforming the power of light ™ Mounting Dimensions H M X 1.78” 11.41” 2.00” STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W T5 ballasts incorporate poke in connectors, for easy installation -C, -D -C -D 14.25” 16.88” 1.18” 1.18” Mounting Dimensions H M X 1.00” 1.00” 13.75” 16.20” For more information, visit www.gelighting.com — — 1-31 ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F24T5HO - One Lamp Applications 120 47534 277 1 PRS 120 47540 277 F24T5HO - Two Lamp Applications 120 47534 277 2 SER-PRS 120 47540 277 F39T5HO - One Lamp Applications 120 47534 277 1 PRS 120 47540 277 F39T5HO - Two Lamp Applications 120 47540 2 SER-PRS 277 F54T5HO- One Lamp Applications 120 47542 1 PRS 277 F54T5HO- Two Lamp Application 120 47542 2 SER-PRS 277 Catalog Number Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor (Amps) (Watts) (PF) (BF) CC HL C US B224PUNV-C • B239PUNV-D • B224PUNV-C • B239PUNV-D • B224PUNV-C • B239PUNV-D FOR (2), (3) & (4) F25T12 (ANSI ONLY) LAMPS • 0.23 0.10 0.27 0.13 28 32 >.98 >.95 >.98 >.90 THD % Min. F/C Start Temp Wiring Diag. Dim. 1.06 <10 0/-18 4b -C 1.25 <10 0/-18 4b -D 0.45 0.19 0.51 0.22 53 52 >.98 1.00 <10 0/-18 4b -C 59 >.98 >.95 1.15 <10 0/-18 4b -D 0.34 0.15 0.39 0.18 41 40 >.98 0.95 <10 0/-18 4b -C 47 >.98 >.95 1.10 <10 0/-18 4b GE Lamp Product Code Starting Line Catalog C (C Pack) Qty. Method Volts Number F25T12 - Two Lamp Applications 120 49707 GE-232-MAX-L/Ultra 277 2 PAR-IS 120 49772 GE-232-MAX-N/Ultra 277 F25T12 - Three Lamp Applications 120 49708 GE-332-MAX-L/Ultra 277 120 3 PAR-IS 49773 GE-332-MAX-N/Ultra 277 80136 347 B332I347HP F25T12 - Four Lamp Applications 120 49709 GE-432-MAX-L/Ultra 277 120 49774 4 PAR-IS GE-432-MAX-N/Ultra 277 -D B239PUNV-D • 0.75 0.32 89 88 >.98 1.00 <10 0/-18 4b -D B254PUNV-D • 0.54 0.24 64 >.98 >.95 1.10 <10 0/-18 4b -D B254PUNV-D • 1.03 0.43 121 117 >.98 1.00 <10 0/-18 4b -D Wiring Diag. Dim. Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor (Amps) (Watts) (PF) (BF) CC HL US • • • • • • • • • • • • • • • • • • • 0.36 0.16 0.41 0.18 >.99 >.96 >.99 >.97 42 48 0.53 0.24 0.61 0.27 0.21 72 71 71 >.99 >.97 >.99 >.98 >.99 0.71 0.31 0.81 0.35 84 83 96 95 >.99 >.97 >.99 >.98 63 TBD TBD TBD TBD 0.79 TBD TBD THD % Min. F/C Start Temp <10 <19 <10 <16 <10 <13 <10 <13 <10 <10 <15 <10 <13 Wiring Diag. Dim. 0/-18 1B -A 0/-18 1B -A 0/-18 1C -A 0/-18 1C -A 0/-18 6 ST 0/-18 1D -A 0/-18 1D -A F25T12 T5HO & T10 T5HO FOR F24, F39, F28 & F54 T5HO LAMPS FOR F40T10 LAMPS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F40T10 - One Lamp Applications 80152 120 80153 277 1 RS 80154 120 80155 277 F40T10 - Two Lamp Applications 80154 120 2 PAR-RS 80155 277 F40T10 - Three Lamp Applications 80156 120 3 PAR-RS 80157 277 Catalog Number Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C THD % Min. F/C Start Temp B140R120HP B140R277HP B240R120HP B240R277HP • • • • 0.34 0.15 0.44 0.19 39 39 48 48 > .98 > .98 > .98 > .98 0.89 0.89 1.03 1.03 < 10 < 10 < 10 < 10 50/10 50/10 50/10 50/10 2 2 4 4 ST ST ST ST B240R120HP B240R277HP • • 0.67 0.29 80 80 > .98 > .98 0.90 0.90 < 10 < 10 50/10 50/10 4 4 ST ST B340R120HP B340R277HP • • 0.98 0.43 116 116 > .98 > .98 0.90 0.90 < 10 < 10 50/10 50/10 5 5 ST ST DIMENSIONS DIMENSIONS IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start Overall Dimensions Draw # L W -C, -D 1-32 ST -C -D IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start 9.50” 14.25” 16.88” 2.40” 1.18” 1.18” transforming the power of light ™ Mounting Dimensions H M X 1.55” 1.00” 1.00” 8.89” 13.75” 16.20” STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W ST -A 9.50” 9.50” 2.40” 1.70” Mounting Dimensions H M X 1.55” 1.18” 8.89” 8.89” 1.69” 1.69” 1.69” — — For more information, visit www.gelighting.com 1-33 ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS FOR (1), (2) & (3) F40T12 LAMPS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F30T12 - One Lamp Applications 80152 120 80153 277 1 RS 80154 120 80155 277 F30T12 - Two Lamp Applications 87049 120 80154 2 PAR-RS 120 80155 277 F30T12 - Three Lamp Applications 80156 120 3 PAR-RS 80157 227 Catalog Number Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C THD % Min. F/C Start Temp Wiring Diag. GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F40T12 - One Lamp Applications 80152 120 80153 277 87219 1 RS 120 80154 120 80155 277 F40T12 - Two Lamp Applications 87219 120 80154 120 80155 2 PAR-RS 277 80156 120 80157 277 F40T12 - Three Lamp Applications 80156 120 3 PAR-RS 80157 277 Dim. B140R120HP B140R277HP B240R120HP B240R277HP • • • • 0.26 0.11 0.33 0.14 30 30 37 37 > .95 > .95 > .95 > .95 0.91 0.91 1.05 1.05 < 10 < 10 < 10 < 10 50/10 50/10 50/10 50/10 2 2 4 4 ST ST ST ST B240R120RH B240R120HP B240R277HP • • • 0.51 0.50 0.22 59 60 60 > .95 > .95 > .95 0.92 0.92 0.92 < 20 < 10 < 10 50/10 50/10 50/10 4 4 4 ST ST ST B340R120HP B340R277HP • • 0.75 0.33 90 90 > .98 >.98 0.91 0.91 < 10 <10 50/10 50/10 5 5 ST ST FOR (1), (2) & (3) F30T12/WM LAMPS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F30T12/WM - One Lamp Applications 80152 120 80153 277 1 RS 80154 120 80155 277 F30T12/WM - Two Lamp Applications 80153 120 2 PAR-RS 80157 277 F30T12/WM - Three Lamp Applications 80156 120 3 PAR-RS 80157 277 Catalog Number Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C B140R120HP B140R277HP B240R120HP B240R277HP • • • • 0.24 0.10 0.30 0.13 27 27 33 33 > .97 > .97 > .95 > .95 0.86 0.86 1.00 1.00 THD % Min. F/C Start Temp < 10 < 10 < 10 < 10 60/16 60/16 60/16 60/16 Wiring Diag. Dim. 2 2 4 4 ST ST ST ST B240R120HP B240R277HP • • 0.46 0.20 53 53 > .98 > .98 0.88 0.88 < 10 < 10 60/16 60/16 4 4 ST ST B340R120HP B340R277HP • • 0.64 0.28 76 76 > .98 > .98 0.88 0.88 < 10 < 10 60/16 60/16 5 5 ST ST US THD % Min. F/C Start Temp Wiring Diag. Dim. B140R120HP B140R277HP B240R120RH B240R120HP B240R277HP • • • • • 0.33 0.14 0.41 0.42 0.18 39 39 46 46 46 > .99 > .99 > .90 > .98 > .98 0.88 0.88 1.09 1.02 1.02 < 10 < 10 < 20 < 10 < 10 50/10 50/10 50/10 50/10 50/10 2 2 4 4 4 ST ST ST ST ST B240R120RH B240R120HP B240R277HP B340R120HP B340R277HP • • • • • 0.62 0.65 0.28 0.70 0.31 73 75 74 84 84 > .98 > .99 > .99 > .98 > .98 0.89 0.88 0.90 1.04 1.04 < 20 < 10 < 10 < 10 < 10 50/10 50/10 50/10 50/10 50/10 4 4 4 5 5 ST ST ST ST ST B340R120HP B340R277HP • 0.94 0.41 113 113 > .99 > .99 0.88 0.88 < 10 < 10 50/10 50/10 5 5 ST ST GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F40T12/WM - One Lamp Applications 80152 120 80153 277 87219 1 RS 120 80154 120 80155 277 F40T12/WM - Two Lamp Applications 87219 120 80154 2 PAR-RS 120 80155 277 FF40T12/WM - Three Lamp Applications 80156 120 3 PAR-RS 80157 277 THD % Min. F/C Start Temp Wiring Diag. Dim. Catalog Number Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C B140R120HP B140R277HP B240R120RH B240R120HP B240R277HP • • • • • 0.28 0.12 0.36 0.35 0.15 33 33 39 39 39 > .98 > .98 > .89 > .98 > .98 0.86 0.86 1.10 0.97 0.97 < 10 < 10 < 20 < 10 < 10 60/16 60/16 60/16 60/16 60/16 2 2 4 4 4 ST ST ST ST ST B240R120RH B240R120HP B240R277HP • • • 0.53 0.54 0.23 62 64 64 > .95 > .99 > .99 0.89 0.86 0.86 < 20 < 10 < 10 60/16 60/16 60/16 4 4 4 ST ST ST B340R120HP B340R277HP • • 0.78 0.34 93 93 > .99 > .99 0.86 0.86 < 10 < 10 60/16 60/16 5 5 ST ST DIMENSIONS STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W ST 1-34 Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor (Amps) (Watts) (PF) (BF) CC HL C FOR (1), (2) & (3) F40T12/WM LAMPS DIMENSIONS IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Catalog Number F40T12 & F40T12/WM F30T12 & F30T12/WM FOR (1), (2) & (3) F30T12 LAMPS 9.50” 2.40” transforming the power of light ™ IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Mounting Dimensions H M X 1.55” 8.89” 1.69” STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W ST 9.50” 2.40” Mounting Dimensions H M X 1.55” 8.89” 1.69” For more information, visit www.gelighting.com 1-35 ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F48T12 - One Lamp Applications 80160 120 1 IS 80161 277 F48T12 - Two Lamp Applications 80158 120 80159 277 2 PAR-IS 80160 120 80161 277 Catalog Number FOR F96T12 LAMPS Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C THD % Min. F/C Start Temp Wiring Diag. Dim. B260I120HP B260I277HP • • 0.39 0.18 47 47 > .95 > .95 1.08 1.08 < 10 < 10 0/-18 0/-18 14 14 SL SL B260I120RH B260I277RH B260I120HP B260I277HP • • • • 0.68 0.29 0.61 0.27 76 76 74 74 > .95 > .95 > .98 > .98 0.92 0.92 0.91 0.91 < 25 < 25 < 10 < 10 0/-18 0/-18 0/-18 0/-18 14 14 14 14 SL SL SL SL GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F96T12 - One Lamp Applications 80158 120 80159 277 1 IS 80160 120 80161 277 F96T12 - Two Lamp Applications 80158 120 80159 277 2 PAR-IS 80160 120 80161 277 Catalog Number Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C THD % Min. F/C Start Temp Wiring Diag. Dim. B260I120RH B260I277RH B260I120HP B260I277HP • • • • 0.73 0.31 0.70 0.31 83 83 84 84 > .95 > .95 > .98 > .98 1.02 1.02 1.05 1.05 < 25 < 25 < 10 < 10 0/-18 0/-18 0/-18 0/-18 14 14 14 14 SL SL SL SL B260I120RH B260I277RH B260I120HP B260I277HP • • • • 1.16 0.50 1.16 0.50 133 133 137 137 > .95 > .95 > .99 > .99 0.86 0.86 0.88 0.88 < 20 < 20 < 10 < 10 0/-18 0/-18 0/-18 0/-18 14 14 14 14 SL SL SL SL THD % Min. F/C Start Temp Wiring Diag. Dim. T12 SLIMLINE & T12 HIGH OUTPUT T12 & T12/WM FOR F48T12 LAMPS FOR F96T12/WM LAMPS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F96T12/WM - One Lamp Applications 80158 120 80159 277 1 IS 80160 120 80161 277 F96T12/WM - Two Lamp Applications 80158 120 80159 277 2 PAR-IS 80160 120 80161 277 FOR F48T12/WM LAMPS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F48T12/WM - One Lamp Applications 80160 120 1 IS 80161 277 F48T12/WM - Two Lamp Applications 80158 120 80159 277 2 PAR-IS 80160 120 81161 277 Catalog Number Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C THD % Min. F/C Start Temp Wiring Diag. Dim. B260I120HP B260I277HP • • 0.36 0.16 42 42 > .95 > .95 1.08 1.08 < 15 < 15 60/16 60/16 14 14 SL SL B260I120RH B260I277RH B260I120HP B260I277HP • • • • 0.60 0.25 0.57 0.25 64 64 66 66 > .95 > .95 > .95 > .95 0.92 0.92 0.93 0.93 < 25 < 25 < 10 < 10 60/16 60/16 60/16 60/16 14 14 14 14 SL SL SL SL Catalog Number Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C B260I120RH B260I277RH B260I120HP B260I277HP • • • • 0.60 0.26 0.59 0.26 66 66 70 70 > .90 > .90 > .98 > .98 1.05 1.05 1.05 1.03 < 25 < 25 < 10 < 10 60/16 60/16 60/16 60/16 14 14 14 14 SL SL SL SL B260I120RH B260I277RH B260I120HP B260I277HP • • • • 0.93 0.40 0.96 0.40 107 107 112 112 > .95 > .95 > .99 > .99 0.88 0.88 0.88 0.88 < 20 < 20 < 10 < 10 60/16 60/16 60/16 60/16 14 14 14 14 SL SL SL SL THD % Min. F/C Start Temp Wiring Diag. Dim. FOR T12 HIGH OUTPUT LAMPS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F72T12HO - Two Lamp Applications 80162 120 2 SER-RS 80163 277 F73T12/BL/HO - Two Lamp Applications 80664 2 SER-RS 120 F84T12HO - Two Lamp Applications 80162 120 2 SER-RS 80163 277 F96T12HO - Two Lamp Applications 80162 120 2 SER-RS 80163 277 FOR F72T12 LAMPS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F72T12 - One Lamp Applications 80158 120 80159 277 1 IS 80160 120 80161 277 F72T12 - Two Lamp Applications 80158 120 80159 277 2 PAR-IS 80160 120 80161 277 Catalog Number Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C THD % Min. F/C Start Temp Wiring Diag. Dim. B260I120RH B260I277RH B260I120HP B260I277HP • • • • 0.60 0.25 0.55 0.25 66 66 67 67 > .90 > .90 > .95 > .95 1.04 1.04 1.06 1.06 < 25 < 25 < 10 < 10 0/-18 0/-18 0/-18 0/-18 14 14 14 14 SL SL SL SL B260I120RH B260I277RH B260I120HP B260I277HP • • • • 0.92 0.39 0.90 0.39 107 107 107 107 > .95 > .95 > .99 > .99 0.90 0.90 0.91 0.91 < 20 < 20 < 10 < 10 0/-18 0/-18 0/-18 0/-18 14 14 14 14 SL SL SL SL IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start 1-36 9.50” 11.75” C B295SR120HP B295SR277HP • • 1.40 0.61 169 169 > .99 > .99 0.95 0.95 < 10 < 10 -20/-29 -20/-29 4 4 SL SL 493B2 • 1.60 180 > .90 1.00 < 25 50/10 4 ST B295SR120HP B295SR277HP • • 1.60 0.69 185 185 > .99 > .99 0.89 0.91 < 10 < 10 - 20/-29 - 20/-29 4 4 SL SL B295SR120HP B295SR277HP • • 1.77 0.76 208 208 > .99 > .99 0.90 0.90 < 10 < 10 - 20/-29 - 20/-29 4 4 SL SL GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F96T12HO/WM - Two Lamp Applications 80162 120 2 SER-RS 80163 277 THD % Min. F/C Start Temp Wiring Diag. Dim. < 10 < 10 60/16 60/16 4 4 SL SL Catalog Number B295SR120HP B295SR277HP Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL C • • 1.47 0.63 174 174 > .99 > .99 0.88 0.88 DIMENSIONS PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W ST SL Certification Line Input Power Ballast UL Type UL Type Current Power Factor Factor US (Amps) (Watts) (PF) (BF) CC HL FOR T12HO/WM HIGH OUTPUT LAMPS DIMENSIONS STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start Catalog Number 2.40” 3.13” IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Mounting Dimensions H M X 1.55” 1.78” transforming the power of light ™ 8.89” 11.41” 1.69” 2.00” STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W ST SL 9.50” 11.75” 2.40” 3.13” Mounting Dimensions H M X 1.55” 1.78” 8.89” 11.41” 1.69” 2.00” For more information, visit www.gelighting.com 1-37 ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT BALLASTS WIRING DIAGRAMS Line Black White BALLAST Blue Blue Blue Red LAMP LAMP LAMP Blue Black Line White Yellow Blue BALLAST Red Red Yellow LAMP LAMP LAMP LAMP DIAGRAM 1 DIAGRAM 1A DIAGRAM 1B DIAGRAM 5 DIAGRAM 6 DIAGRAM 7 DIAGRAM 1C DIAGRAM 1D DIAGRAM 2 DIAGRAM 7A DIAGRAM 8 DIAGRAM 13 DIAGRAM 3 DIAGRAM 4 DIAGRAM 14 DIAGRAM 23 DIAGRAM 30 WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAMS DIAGRAM 4A DIAGRAM 4B 1-38 transforming the power of light ™ For more information, visit www.gelighting.com 1-39 ELECTRONIC BALLASTS ELECTRONIC BALLASTS The effective dimming of fluorescent lights delivers a wide range of benefits: greater control of workspace lighting, ability to create a mood, energy savings, and more. Our electronic T8 fluorescent dimming products help you save as much as 30% on energy bills—and they meet today’s toughest specification requirements, including ASHRAE 90.1 and California Title 24. GE offers three options for variable lighting control: continuous dimming (100% to 5%) and two forms of light level switching (either 100/50% or 100/60/30%). Dimming ballasts from GE are designed to ensure optimum lamp performance. Their Lamp Current Crest Factors are well below the maximum 1.7 ANSI standard — and they start the lamps according to ANSI recommendations throughout the entire dimming range. Both of these important design parameters ensure optimum lamp performance. In addition, our dimming ballasts actually increase cathode heating when dimming to maintain the cathode’s proper temperature, which enhances lamp life and performance stability. Continuous Dimming (V5) • 1, 2 & 3 lamp models with full range dimming (100% to 5%) • Designed for optimal lamp performance — Cathode voltage increases as lamps dim — Positive starting at all dimming levels — No lamp dropout — No flicker at all dimming levels APPLICATION AND OPERATING INFORMATION • Line voltage control circuit protection — Miswiring of control leads will not damage the ballast • Compatible with all 0 to 10 Volt DC controls and photocells • Maximum energy savings versus comparable ballasts on the market • THD <10% throughout the entire dimming range • 120, 277 and 347 Volt models available Light Level Switching (S30 & S50) • 1, 2, & 3 lamp models for 120 & 277 Volt • Switches to preset light levels, keeping all lamps illuminated • Eliminates the dark spots associated with inboard/outboard • Connects with two line voltage power leads — Wires the same as an inboard/outboard fixture — No special controls required; uses two wall switches • Meets all ASHRAE 90.1 and California Title 24 requirements for lighting control • THD <10% • Lower installed costs; less wiring and equipment required SAFETY Dimming ballasts follow the same guidelines as electronic ballasts in regard to the application and operating information. In addition to the section for electronic ballasts, the following applies specifically to dimming electronic ballasts. See pages 1-13 and 1-14 for electronic ballast application and operating information. V5 dimming ballasts are controlled by using 10-0vDC. Care should be taken to ensure that the line voltage (AC) wires are not connected to the low voltage DC wires. Electronic dimming ballasts have a protection circuit that will sense if the ballast has been connected in this manner and not harm the ballast or the installer. If connected in this mode, the lamps will dim to the 30% level. Compatible Dimming Controls For a listing of compatible controls for the V5 dimming ballasts, please see page1-45 in this catalog. Fusing Class P ballasts do not require fusing. Fusing can be used when a single circuit has a large number of fixtures/ballasts. For a comprehensive list of appropriate fuses, contact your GE representative. DIMMING APPLICATION & OPERATING INFO. DIMMING PRODUCT OVERVIEW DIMMING PRODUCT OVERVIEW New Lamp Installation When new lamps are installed, they must operate at a full bright level for a minimum of 100 hours prior to dimming. Failure to do this will effect lamp life and cause the lamps to not dim properly. Consult your lamp manufacturer for further lamp information. Light Level Switching Installation Note The two power leads for the light level switching ballasts must be connected to the same power circuit. The leads should connect to separate switches or relays for control of the light level switching operation. Connection of the input leads to separate power circuits can damage the ballasts and cause electrical system problem. Note: Do not connect any other ballast to the load side of the switches controlling the switched dimming ballast. GE dimming ballasts help you save as much as 30% on energy bills. 1-40 GE Light Level Switching for ultimate control. transforming the power of light ™ For more information, visit www.gelighting.com 1-41 ELECTRONIC BALLASTS ELECTRONIC BALLASTS CONTROLS CROSS REFERENCE 1-42 Continuous Dimming & Light Level Switching 1. Ballasts shall operate from 60 Hz input source of 120, 277 Volts, and sustained variations of ±10% (Voltage & Frequency) with no damage to the ballasts. 2. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz. 3. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. 4. Ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage. 5. Ballasts shall comply with FCC Part 18 NonConsumer Equipment for EMI (power line conducted) and RFI (Radiated). 6. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991. 7. Ballasts shall operate lamps with no visible flicker (<3% flicker index). 8. Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage. 9. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. 10. Ballast shall have a Ballast Factor greater than .85 per ANSI C82.11-1993, in the 100% light position. 11. Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp. 12. Ballasts shall have a Power Factor greater than .98 for primary lamp. 13. The ballasts shall not have any PCBs. 14. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of manufacture. 15. Ballast shall be manufactured in an ISO 9001 Certified Facility. 16. Ballasts shall provide rapid starting sequence consistent with ANSI standard C82.11-1993. 17. GE model ___________ (or approved equal). Continuous Dimming: From 100% to 5% (V5 Ballast) • Ballast 10-0 Volt (DC) control leads shall have safety/protection circuitry to protect the ballast against improper wiring of line voltage (AC) to control leads (DC). • In the event of improper wiring, the ballast will operate with no harm to the ballast or user. The ballast will dim to a 30% light level. • All lamps must remain on at low light levels (No Lamp Dropout). Light Level Dimming: From 100% to 60% to 30% or 100% to 50% (S30/S50 Ballasts) • Ballast(s) must be operable with two standard wall switches or relays. • Both switches must be wired on same phase of circuit. • Ballast(s) must be compatible with Power Line Carrier (PLC) Systems. • Ballast must provide equal lamp current to each lamp at all settings. transforming the power of light ™ Company Name & Phone Electronics Diversified 800-547-2690 Prolight Dimming System Honeywell 800-345-6770 use with EL7305A1010 Hunt Dimming 970-484-9048 Leviton 800-824-3005 DPSPE-212 Lightolier Controls 800-526-2731 Vega Slider LEQ BC Lithonia Controls 800-533-2719 SQ1DC Novitas 310-568-9600 PLC Multipoint 425-353-7552 Prescolite Controls 800-DIMMERS PA7 Sensor Switch 800-727-7483 Thomas Industries 601-842-7212 UNENCO 800-227-0452 Watt Stopper 800-879-8585 Compatible Ballasts Slide Dimmer or Modules Photo Sensor 10-0 Volts MX Dimming System Versa-Pak Dimming System EL7315A1019 EL7315A1009 PS-010-xxx Centura Illuma Tech IP7 Centura Photocell: 0DC0P DIMMING CONTROLS CROSS REFERENCE DIMMING SPECIFICATIONS TYPICAL SPECIFICATIONS FOR DIMMING BALLASTS Sunrise Slider Momentum Slider LEQ LVBC SLD LVBC LEQ DPC 01-PCx EDSAB RCD Element EW-EF CM-ALC DHC-LSD Daylight Tracker DT-D LS-4 LCD-1xx use with LCD-101 and LCD-103 LS-xxx B332SRxxxV5 (xxx = 120 or 277) B232SRxxxV5 (xxx = 120, 277 or 347) B132RxxxV5 (xxx = 120, 277 or 347 Data Subject to Change Without Notice For more information, visit www.gelighting.com 1-43 ELECTRONIC BALLASTS ELECTRONIC BALLASTS DIMMING BALLASTS FOR (2), (3) & (4) F32T8 LAMPS DIMMING F25T8 & F32T8 GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F25T8 - One Lamp Applications 80365 120 80366 277 80359 1 RS 120 80360 277 80353 120 80354 277 86446 347 Catalog Number B132R120S30 B132R120S30 B132R120S30 B132R277S30 B132R277S30 B132R277S30 B132R120S50 B132R120S50 B132R277S50 B132R277S50 B132R120V5 B132R120V5 B132R277V5 B132R277V5 B132R347V5 B132R347V5 Certification UL Type C US CC @ 100% @ 60% @ 30% @ 100% @ 60% @ 30% @ 100% @ 50% @ 100% @ 50% @ 100% @ 5% @ 100% @ 5% @ 100% @ 5% Line Current (Amps) Input Power (Watts) Power Factor (PF) Ballast Factor (BF) THD % Min. F/C Start Wiring Temp Diag. GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F32T8 - Two Lamp Applications Dim. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 0.20 0.16 0.10 0.10 0.08 0.06 0.24 0.13 0.10 0.06 0.22 0.06 0.10 0.03 0.08 0.02 24 19 12 27 21 13 29 16 27 17 26 7 26 7 26 7 > .99 > .99 > .98 > .98 > .95 > .90 > .99 > .98 > .98 > .95 > .99 > .90 > .99 > .90 > .99 > .90 0.93 0.62 0.29 0.91 0.63 0.28 0.92 0.46 0.91 0.47 0.90 0.05 0.90 0.05 0.90 0.05 < 10 < 10 < 15 < 10 < 25 < 25 < 10 < 10 < 10 < 20 < 10 < 15 < 10 < 20 < 10 < 30 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 15 15 15 15 15 15 15 15 15 15 18 18 18 18 18 18 ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST 2 SER-RS 277 B232SR277S50 @ 100% B232SR277S50 @ 50% • • • • 0.18 0.11 48 29 > .99 > .95 0.88 0.45 < 10 < 20 50/10 50/10 16 16 ST ST 80365 120 80366 277 80359 1 RS 120 80360 277 80353 120 80354 277 86446 347 Catalog Number B132R120S30 @ 100% B132R120S30 @ 60% B132R120S30 @ 30% B132R277S30 @ 100% B132R277S30 @ 60% B132R277S30 @ 30% B132R120S50 @ 100% B132R120S50 @ 50% B132R277S50 @ 100% B132R277S50 @ 50% B132R120V5 @ 100% B132R120V5 @ 5% B132R277V5 @ 100% B132R277V5 @ 5% B132R347V5 @ 100% B132R347V5 @ 5% Certification UL Type C US CC • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Line Current (Amps) Input Power (Watts) Power Factor (PF) Ballast Factor (BF) THD % 0.27 0.19 0.12 0.13 0.09 0.06 0.27 0.16 0.13 0.07 0.27 0.07 0.12 0.03 0.09 0.02 32 23 14 33 25 15 32 19 36 19 32 8 32 8 32 8 > .99 > .99 > .98 > .99 > .98 > .95 > .99 > .98 > .99 > .95 > .99 > .90 > .99 > .90 > .99 > .90 0.89 0.60 0.28 0.89 0.63 0.28 0.89 0.44 0.89 0.45 0.88 0.05 0.88 0.05 0.88 0.05 < 10 < 10 < 10 < 10 < 15 < 20 < 10 < 10 < 10 < 20 < 10 < 10 < 10 < 15 < 10 < 20 Min. F/C Start Wiring Temp Diag. 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 15 15 15 15 15 15 15 15 15 15 18 18 18 18 18 18 2 SER-RS 120 80362 277 80355 120 80356 277 86448 347 80362 277 Line Current (Amps) Input Power (Watts) Power Factor (PF) Ballast Factor (BF) THD % Min. F/C Start Wiring Temp Diag. Dim. B232SR120S30 @ 100% B232SR120S30 @ 60% B232SR120S30 @ 30% B232SR277S30 @ 100% B232SR277S30 @ 60% B232SR277S30 @ 30% B232SR120S50 @ 100% B232SR120S50 @ 50% B232SR277S50 @ 100% B232SR277S50 @ 50% B232SR120V5 @ 100% B232SR120V5 @ 5% B232SR277V5 @ 100% B232SR277V5 @ 5% B232SR347V5 @ 100% B232SR347V5 @ 5% B232SR277S50 @ 100% B232SR277S50 @ 50% • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 0.52 0.38 0.24 0.23 0.17 0.11 0.52 0.31 0.23 0.14 0.52 0.12 0.23 0.05 0.18 0.04 0.23 0.14 62 45 28 62 45 28 62 37 62 37 62 13 62 13 62 13 62 37 > .99 > .95 > .95 > .99 > .95 > .95 > .99 > .95 > .99 > .95 > .99 > .90 > .99 > .90 > .99 > .90 >.99 >.90 0.88 0.58 0.27 0.88 0.58 0.27 0.88 0.48 0.88 0.48 0.88 0.05 0.88 0.05 0.88 0.05 0.88 0.48 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 15 < 10 < 15 <10 <10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 16 16 16 16 16 16 16 16 16 16 19 19 19 19 19 19 16 19 ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST 80369 120 B332SR120S30 @ 100% B332SR120S30 @ 60% B332SR120S30 @ 30% B332SR277S30 @ 100% B332SR277S30 @ 60% B332SR277S30 @ 30% B332SR120S50 @ 100% B332SR120S50 @ 50% B332SR277S50 @ 100% B332SR277S50 @ 50% B332SR120V5 @ 100% B332SR120V5 @ 5% B332SR277V5 @ 100% B332SR277V5 @ 5% • • • • • • • • • • • • • • • • • • • • • • • • • • • • 0.78 0.61 0.40 0.34 0.26 0.16 0.78 0.50 0.34 0.22 0.77 0.17 0.33 0.07 93 69 43 94 69 43 93 57 93 57 92 20 92 20 > .99 > .95 > .95 > .99 > .95 > .95 > .99 > .95 > .99 > .95 > .99 > .90 > .99 > .90 0.88 0.60 0.30 0.88 0.60 0.30 0.88 0.48 0.88 0.48 0.88 0.05 0.88 0.05 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 15 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 17 17 17 17 17 17 17 17 17 17 20 20 20 20 ST ST ST ST ST ST ST ST ST ST ST ST ST ST 80370 277 ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST 3 SER-RS 120 80364 277 80357 120 80358 277 B432SR277V5 @ 100% B432SR277V5 @ 5% • • • • 0.42 0.11 112 27 > .99 > .90 0.88 0.05 < 10 < 15 50/10 50/10 26 26 -ZZ -ZZ F32T8 - Four Lamp Applications ????? 4 SER-RS 277 DIMENSIONS STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start ST IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W 1-44 277 80363 Dim. DIMENSIONS IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start 80368 Certification UL Type C US CC F32T8 - Three Lamp Applications DIMMING BALLASTS FOR (1) F32T8 LAMPS GE Lamp Product Code Starting Line (C Pack) Qty. Method Volts F32T8 - One Lamp Applications 120 80361 F25T8 - Two Lamp Applications 80362 80367 Catalog Number DIMMING F32T8 DIMMING BALLASTS FOR (1) & (2) F25T8 LAMPS 9.50” 2.40” transforming the power of light ™ Mounting Dimensions H M X 1.55” 8.89” 1.69” STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start Overall Dimensions Draw # L W ST -ZZ 9.50” 16.40” 2.40” 2.40” Mounting Dimensions H M X 1.55” 1.50” 8.89” 15.88” 1.69” 1.69” For more information, visit www.gelighting.com 1-45 ELECTRONIC BALLASTS DIMMING DIAGRAMS DIMMING WIRING DIAGRAMS 1-46 DIAGRAM 15 DIAGRAM 16 DIAGRAM 17 DIAGRAM 18 DIAGRAM 19 DIAGRAM 20 transforming the power of light ™ ELECTROMAGNETIC FLUORESCENT BALLASTS A WIDE PRODUCT LINE TO MEET ALL YOUR NEEDS GE's full spectrum of solutions includes ballasts for T12/T10/T8 applications, plus Slimline, Circline, triggerstart and preheat ballasts. We also make rugged weatherproof ballasts...and models specifically engineered for the fast growing export market. ELECTROMAGNETIC FLOURESCENT BALLASTS Our comprehensive line of magnetic ballasts offers outstanding performance and value. These energy-efficient ballasts are available for a wide variety of applications. GE has a comprehensive line of energy-efficient magnetic ballasts for T12, T10 and T8 applications. For more information, visit www.gelighting.com 2-1 ELECROMAGNETIC FLUORESCENT BALLASTS ELECROMAGNETIC FLUORESCENT BALLASTS Rapid Start Ballasts These ballasts provide smooth starting to rapid start lamps – reaching full brightness in about two seconds without the use of starters. They have built-in filament windings that energize the low-voltage cathodes in rapid start lamps. Because electrodes are continuously heated, less voltage is required to strike an arc through a rapid start lamp than a slimline one. Rapid Start Ballasts PRODUCT OVERVIEW Ballasts for T8 Applications GE‘s T8 product offering includes models for F17, F25, F32 and F40 type T8 lamps. This product line features OcTek™ electromagnetic ballast models. These models are low initial cost energy efficient options for use with F32T8, 4-foot rapid start lamps. These models are available in several variations, including full, medium, low light output and hybrid versions (OkTek™ Plus). These models maximize energy savings and provide effective choices when retrofitting 4-foot T12 fixtures. PRODUCT OVERVIEW T8 Applications Ballasts for T12/T10 Applications GE offers a wide variety of T12 and T10 ballasts to operate 1-3 rapid start lamps. This lamp/ballast system provides smooth, virtually instant starting without the use of starters (30-and 40-watt T12 models and 40-watt T10 models are available). Models for U-lamp applications are also available. These “hybrid” type ballasts incorporate an electronic switch which disconnects power to the lamp cathodes after start-up, saving additional energy. T12/10 Applications Rapid Start Dimming Ballasts Light levels produced by fluorescent lamps can be adjusted by using rapid start dimming ballasts in conjunction with proper control devices. These ballasts are generally for one- and two-lamp operation of 40watt rapid start lamps – and they may also be used with 30-watt rapid start lamps. However, 30-watt lamps and 40-watt lamps should not be mixed on the same dimming control. Different colors and brands of lamps, or different ballast brands, also should not be mixed on the same dimming control. All dimming ballasts are recommended for use with phase controlled-type dimming controls only and subject to the approval of the dimming control manufacturer. Circline Ballasts These products are available in 430 mA rapid start and preheat types, designed for use with circline lamps. The operating characteristics are the same for both circline and conventional lamps. All circline socket wires are fully sleeved. Trigger-Start Ballasts These ballasts are designed for use with general fluorescent lamps and do not require the use of starters. They contain preheat windings which allow regular lamp filaments to be heated in one second. However, they require a higher open-circuit voltage than rapid start ballasts. Preheat Ballasts These units are designed for use with general fluorescent lamps and require the use of starters. These ballasts deliver an open-circuit voltage high enough to activate the starter to preheat lamp filaments to a temperature approximately 1750°F. After a few seconds, the starter opens the filament circuit. This provides an additional power surge to enable an electric arc to strike through the lamp and ignite it. Lamp current is then limited by the ballast to an operating level proper for the lamp. Preheat Ballast Weatherproof Ballasts Ballasts designated as “weatherproof” are designed to withstand direct exposure to rain and snow and are Underwriters Laboratories, Inc.–approved for this purpose. The weatherproof ballasts listed within the catalog are enclosed in a round extruded aluminum can with the cover sealed be a double-rolled seam. It is supplied with a detached aluminum mounting bracket containing four keyholes and a stainless steel band with a threaded fastener. The mounting bracket can be located at any point on the cylinder portion of the ballast. There is no junction box supplied with the ballast. A standard 3/4", 14 N.P. thread nipple is provided at one end of the ballast to allow for the selection of a weathertight junction box most applicable to the particular needs and local electrical code requirements. Export (50/60 Hz) Ballasts Our export product offering consists of a variety of one- and two-lamp models for rapid start, preheat, high output, slimline, and 1500 mA lamps. Included in this product line are ballasts for 50 and 60 Hz applications, including 110, 120, 127, 220, 230, 240, and 277 Volts. Many of these models are available with resetting thermal protection. PRODUCT OVERVIEW PRODUCT OVERVIEW Export (50/60 Hz) Ballast Rapid Start Dimming Ballasts Slimline Ballasts Our slimline models are designed for use with single-pin slimline lamps. They do not require the use of starters. These ballasts deliver a high-starting voltage to the lamps, enabling an arc to strike through the tube without preheating the lamp cathodes (which are specially constructed to withstand the shock). Slimline Ballasts 2-2 transforming the power of light ™ For more information, visit www.gelighting.com 2-3 ELECROMAGNETIC FLUORESCENT BALLASTS ELECROMAGNETIC FLUORESCENT BALLASTS APPLICATION AND OPERATING INFORMATION APPLICATION AND OPERATING INFORMATION SAFETY PERFORMANCE APPLICATION AND OPERATING INFORMATION NEC & UL Requirements Ballast installation presents the possibility of exposure to potentially hazardous voltages and should be performed only by qualified personnel. All installation, inspection, and maintenance should be performed only with power to the fixture turned off. Additionally, all fixtures and ballasts must be installed and operated in compliance with the National Electrical Code, Underwriters Laboratories Inc. (UL) requirements, and all local applicable codes and regulations. Polarity Polarity refers to the proper connection of ballast lead wires to line wires. To aid you in making a correct installation, GE ballast leads are color-coded for easy identification. The WHITE ballast lead is to be connected to the neutral (grounded) and the BLACK (or black with white tracer) lead always to the phase (“hot”) line wire. Systems where neither of the line wires are at ground potential require specially designed ballasts. A change in polarity may result in the voltage from the lead to the ground exceeding UL-specified limits. In some types of ballasts, a change in polarity may decrease voltage from the lead to the ground, thereby impeding the starting dependability of the ballast. Grounding Ballast cases and fixtures must always be grounded. The ballast case may be grounded to the fixture or otherwise grounded. It could be hazardous to make contact with an ungrounded fixture or ballast when in operation. Neglecting to properly ground the ballast and fixture combination may also result in failure of certain lamps to start or for unacceptable levels of electromagnetic noise to be conducted onto the power lines. Operating Line Voltage Limits To receive the full benefits of rated lamp output and to prolong ballast life, it is essential that voltage supplied to an installation be maintained within limits prescribed for each circuit. These limits are listed in the next column. 2-4 Nominal Voltage 120 220 240 277 347 480 600 Minimum 110 205 220 255 315 450 570 Maximum 125 232 250 290 364 505 630 Subjecting a ballast to excessive voltage for an extended period results in the deterioration of the insulation. This insulation breakdown will cause early ballast failure. Low voltage has no damaging effect on the ballast. However, lamps may not start reliably, and early lamp failure could result. Internal Ballast Protection Class P Classification – Since January 1, 1984, the National Electrical Code requires that “where Fluorescent fixtures are installed indoors, the ballast shall have thermal protection integral within the ballast except for simple reactance ballasts.” This ruling applies to replacement ballasts as well as to those contained within new light fixtures. In compliance with the National Electrical Code, UL has established a Class P ballast classification for fluorescent light fixtures indoors. A Class P ballast must employ internal thermal protection limiting its operating temperature. GE UL-approved Class P ballasts comply with the National Electrical Code requirement and are equipped with an automatic resetting thermal protector, built-in and adjacent to the transformer coils. The resetting thermal protector functions as a thermostat, which will open and temporarily deactivate the ballast when it exceeds the permissible temperature. It will reset when the ballast cools to a safe operating temperature. The ballast will continue to cycle until the cause of overheating is eliminated. If the ballast is defective, it must be replaced. If the cause is external, a Class P ballast will resume normal operation after abnormal conditions are eliminated. Fusing Class P ballasts do not require fusing. Fusing can be used when a single circuit has a large number of fixtures/ballasts. For more information, contact your GE Lighting representative or visit www.gelighting.com. transforming the power of light ™ Lamp Connections Electromagnetic and hybrid ballasts may be Electromagnetic fluorescent ballasts are designed remote mounted according to the table below: to generate voltages in excess of 300 Volts. It is imperative that proper connection to good quality Wire size 30-40 Watt 800 mA - HO Instant Start Rapid Start 1500 mA - VHO (Slimline) sockets be assured in accordance with wiring diaRed/Blue Yellow Red/Blue Yellow All Leads grams throughout this catalog and on product labels. Leads Leads Leads Leads Some applications may not require the use of all of 544' #6 544' 384' 272' 192' the ballast output leads. If any leads are not to be 340' #8 340' 240' 170' 120' connected, each should be individually capped and 214' #10 214' 150' 107' 75' insulated to at least 600 Volts. 134' #12 134' 94' 67' 47' Application Versatility Many GE models are designed to allow for applications with different types or quantities of lamps. Use of products other than noted is not covered by UL Listing and/or CSA certification and cannot be warranted. Audible Noise (Sound) Electrical equipment, including most fluorescent lamp ballasts, produces some noise. Care must be taken to select a ballast with the proper sound rating for a particular lighting installation. Ballast sound will be noticeable only when it exceeds the ambient sound level. Although no industry standards currently exist, the generally accepted criteria for sound rating specifications are as follows: Location Typical Office Noisy Office or Retail Factory, Outdoor Average Ambient Noise < 30 decibels 31-36 decibels > 36 decibels Ballast Recommendation A B C Remote Mounting Excessive hot or cold temperatures, audible noise requirements, or a desire to operate lamps in more than one fixture with the same ballast (master/slave), may make it desirable to mount the ballast remotely. Care must be taken to allow for ballast heat dissipation and proper grounding. In any application, the wire used to extend leads must be at least as large as the wire supplied on the ballast (18 AWG) with an insulation rating of 1000 VAC at 90°C. Lead lengths in excess of those noted cause loading effects that can dramatically impact ballast performance and void the warranty. #14 #16 #18 84' 52' 30' 60' 36' 20' 42' 26' 21' 30' 18' 15' 84' 52' 30' Operating Temperature Most fluorescent ballasts and lamps are designed to provide optimum performance at an ambient temperature of 77°F. Three key performance attributes can be impacted by the ambient (room) temperature of the installation: APPLICATION AND OPERATING INFORMATION VOLTAGE RANGE • Lamp Starting Dependability Fluorescent lamps are inherently more difficult to start at low temperatures. All ballasts have limitations as to their ability to start lamps at low ambient temperatures. In this catalog, the low starting point for each lamp/ballast combination appears in the column marked ”Minimum Starting Temperature.“ • Light Output Optimum light output from fluorescent lamps is achieved when the lamp wall is at 100110°F. Any substantial excursion (either colder or warmer) will result in a reduction in light output. • Ballast Life A fluorescent lamp ballast, like any other electrical device, generates heat during its normal operation. Ballast temperatures should be kept as low as possible. Maximum dissipation of heat through fixture design and proper ballast installation will help. Although excessive temperature may not cause the ballast to fail immediately, it can shorten ballast life. To assure maximum life, the ballast case temperature should not exceed 90°C. For more information, visit www.gelighting.com 2-5 ELECROMAGNETIC FLUORESCENT BALLASTS ELECROMAGNETIC FLUORESCENT BALLASTS APPLICATION AND OPERATING INFORMATION Operating Temperature, continued Causes of ballast overheating: • Incorrect primary voltage or frequency • Incorrect size, type or number of lamps • Failed lamp starter • Incorrect wiring • Poor heat dissipation due to surrounding insulation • Sealed (Vapor Tight) Fixtures - Unusual heat build-up due to lack of ventilation in fixtures may cause thermal (on/off) cycling of certain ballasts. Consult GE for specific recommendations. Recommendations: • Selection of a proper ballast to match the requirements of the lamp, fixture, voltage and installation • Mounting of ballast within the fixture with as much surface contact as possible between the ballast and metal portions of the fixture. • The use of heat-conducting dissipators (radiators), if necessary, which increases surface contact between the ballast and fixture. • If necessary, locate the ballast in a remote, cooler area outside the fixture. • Planned lamp maintenance – the organized replacement of failed and failing lamps, particularly with preheat or slimline systems. • Use of special LOW HEAT (-LH) rise, VERY LOW HEAT (-VLH) rise, and SUPER LOW HEAT (-SLH) rise ballasts where available and necessary. LOW-LEAKAGE CURRENT TO GROUND BALLASTS Many one- and two-lamp, 30- and 40-watt high power rapid start ballasts, and two- and three-lamp 20-watt trigger start ballasts, meet requirements for “low-leakage-current-to-ground.” Those most frequently used in low-leakage applications are listed in the next column. 2-6 Lamps Line Maximum Voltage Leakage @60Hz To Ground (2)F30T12/RS (1)F40T12/RS (2)F40T12/RS (1)F40T12/RS (2)F40T12/RS 120 120 120 277 277 20uA 30uA 30uA 50uA 50uA SPECIFICATIONS GE Product Code Catalog Number 86251 573-L-TC-P-IP 86101 412-L-SLH-TC-P-IP 86137 446-L-SLH-TC-P 96158 458-L-SLH-TC-P-IP 86123 443-L-SLH-TC-P Other ballasts can also be manufactured to meet low-leakage requirements. Consult GE for complete information regarding low-leakage ballasts. TYPE 1 BALLASTS All GE outdoor non-weatherproof magnetic ballasts (except those for sign applications) are designed to meet UL requirements for Type 1 use (metal enclosure required for wet or damp locations). BALLASTS FOR GERMICIDAL LAMPS GE manufactures ballasts to operate germicidal lamps. When ordering, make sure the ANSI designation of the germicidal lamp matches exactly with the ballast's recommended application. Several typically encountered germicidal lamps are listed below along with the proper GE ballast for their operation. Contact GE Lighting for additional information or applications not listed. Germicidal Lamp GE Ballast See Page Number (1)G15T8 200-H2 2-19 - 2-20 All high power factor ballasts are equipped with capacitators. Oil-filled capacitators contain non-resetting internal protection and are manufactured without PCBs. transforming the power of light ™ TYPICAL SPECIFICATIONS FOR ELECTROMAGNETIC BALLASTS 1. Ballasts shall be certified energy saving magnetic type and operate lamps at a frequency of 60 Hz. 2. Ballasts shall be specifically designed to operate (Quantity & Type) lamps. 3. Ballasts shall operate from 60 Hz input source of _______ Volts*, and tolerate sustained variations of +5%-10% with no damage to the ballasts. 4. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location Category A1. 5. Ballasts shall provide starting sequence consistent with ANSI standard C82.1. 6. Ballasts shall tolerate sustained open circuit and short circuit output conditions with no damage to the ballasts. 7. Ballasts shall be: • UL LISTED as Class P and for use in indoor or Type 1 outdoor applications. • CSA CERTIFIED where applicable (120 and 347 Volt models). 8. Ballasts shall tolerate operation, in most fixtures, at ambient temperatures up to 105°F (40°C). Ballast enclosure is limited to 90°C maximum temperature. 9. Ballasts shall have a Power Factor greater than .90. 10. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturers recommendation and ANSI C82.11-1993. • 1.85 or less for instant start Slimline (also per ANSI C82.1). 11. Ballasts shall have a Ballast Factor greater than .925 per ANSI C82.11-1993. • .95 or greater for HO and VHO applications. 12. Input current Total Harmonic Distortion shall not exceed .32 per ANSI C82.1. 13. Ballasts shall be fully encapsulated (potted) to ensure maximum thermal and structural integrity. 14. Manufacturer shall provide written warranty against defects in material or workmanship. 15. Manufacturer shall have been manufacturing electromagnetic ballasts for at least twenty years. 16. Ballast shall be manufactured in North America 17. GE model*______________ (or approved equal). For more information, visit www.gelighting.com SPECIFICATIONS APPLICATION AND OPERATING INFORMATION 2-7 ELECROMAGNETIC FLUORESCENT BALLASTS ELECROMAGNETIC FLUORESCENT BALLASTS LEAD LENGTHS 1 1 L L L L L L 68 18 18 10 20 8 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 L L L L L L L L L L L L L L L L L 10 10 10 22 22 18 20 22 18 68 68 68 68 68 18 18 10 20 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 2 2 2 2 R R R R R R R L R R R R R R R R R R R L R R R R L R R R R R R R R R R 27 1 1 1 1 2 2 1 2 2 2 2 2 2 2 2 1 1 2 1 1 R 26 26 23 29 24 26 9 26 13 27 46 46 46 46 33 38 27 24 17 9 26 23 30 24 26 9 26 13 37 46 46 46 46 33 26 27 24 12 9 9 13 10 13 25 25 20 26 26 33 44 44 44 44 44 46 46 49 38 R L R R R R R R R R R R R L R R L R 2 2 2 2 2 2 2 2 2 1 R R R R R R R R R 13 10 13 25 25 20 26 26 33 44 1 R 45 1 2 2 2 2 R R R L R 44 46 46 52 38 1 32 2 2 L L 36 36 2 2 L L 36 18 2 2 2 2 2 2 L L L L L R 65 65 65 65 51 26 2 L 36 2 L 16 2 2 2 2 L L L L 16 26 26 32 1 R L 27 38 1 2 R L 20 42 R 23 2 L L 65 65 2 L 47 Lead Quantities (per color) Exits (L=Left, R=Right, B=Bottom) Lengths (in inches, +/- 1") Catalog Number 277 120 277 697-L-TC-P-IP 573-L-TC-P-IP 588-L-TC-P-IP • • • • • • 120 413-C-TC-P-IP • • 120 277 573-L-TC-P-IP 588-L-TC-P-IP • • • • Line Current NOM (Amps) • Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. .16 .66 .29 44 79 79 .98 .95 .96 2.23 1.21 1.21 < 1.7 < 1.7 < 1.7 < 20 < 20 < 20 50/10 50/10 50/10 A A A 42 1 1 D2 D2 D2 .63 37 .72 1.95 < 1.7 < 10 50/10 A 8 D1 .57 .26 67 70 .89 .92 1.33 1.31 < 1.9 < 1.9 < 20 < 20 60/15 60/15 A A 1 1 D2 D2 GE Lamp Product Code Qty. Descr. F40T12 - High Power Factor 86101 1 Rapid 86158 1 Rapid 86110 2 Hybrid 86137 2 Rapid 86208 2 Hybrid 86123 2 Rapid F40T12- Normal Power Factor 86105 1 Rapid Certification Line Volts Catalog Number Ballast Efficacy Crest Factor Factor THD % 120 412-L-SLH-TC-P-IP★ • 277 458-L-SLH-TC-P-IP★ • 120 420-L-TC-P-IP◆ • 120 446-L-SLH-TC-P • 277 537-L-TC-P-IP◆ • 277 443-L-SLH-TC-P • • • • • • • • • • • • • 120 • • 413-C-TC-P-IP❉ • • • • • • Line Current NOM (Amps) • • Input Power Ballast (Watts) Factor Min. F/C Start Sound Wiring Temp Rating Diag. Dim. • .45 .19 .62 .75 .31 .34 52 51 72 89 82 90 .95 .95 .85 .94 .94 .95 1.83 1.86 1.18 1.06 1.15 1.06 < 1.7 < 1.7 < 1.7 < 1.7 < 1.7 < 1.7 < 20 < 20 < 20 < 20 < 20 < 20 50/10 50/10 50/10 50/10 50/10 50/10 A A A A A A 42 42 1 1 1 1 D2 D2 D2 D2 D2 D2 • .53 36 .61 1.69 < 1.7 < 20 50/10 A 8 D1 NOM Line Current (Amps) Ballast Efficacy Crest Factor Factor THD % • F40T12/WM LAMPS 36 51 2 2 Certification Line Volts ★ Not for use with “U” lamps ◆ Not for use with Energy Saver “U” lamps ❉ For Residential Use Only 2 L GE Lamp Product Code Qty. Descr. F30T12 - High Power Factor 86287 1 Rapid 86251 2 Rapid 86253 2 Rapid F30T12 - Normal Power Factor 86105 1 Rapid F30T12/WM - High Power Factor 86251 2 Rapid 86253 2 Rapid F40T12 LAMPS 2 2 2 Length R Exit 1 Quantity 27 Length R Exit 1 Brown T12 27 32-12 L 41 L 29 L 20 L 22 L/R 10 L 22 L 10 L 25 L 18 L 18 L 18 L 18 L 18 L 38 L 42 L 20 L 17 L/R 10 27 Quantity L Length 1 2 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 2 Exit Exit Length 8 68 1 1 1 1 1 1 L R Quantity 10 10 10 22 22 18 20 22 18 68 25 1 Length L L L L L L L L L L L 13 Blue/White Exit 1 1 1 1 1 1 1 1 1 1 1 R Yellow Quantity 18 18 18 18 18 20 10 20 10 10 2 Blue Length L L L L L L L L L L Exit 1 1 1 1 1 1 1 1 1 1 L Quantity L L L L L L L 13 8-15 8 12 41 9 20 22 10 22 10 Red Length R White Exit 1 2 1 1 1 1 1 1 1 1 1 Quantity 200-C-S-P-IP 200-H2-IP 202-B-TC-P-IP 202-SB-TC-IP 213-TC-P-IP 413-C-TC-P-IP 420-L-TC-P-IP 443-L-SLH-TC-P 445-RS-WS-TC-P-IP 446-L-SLH-TC-P 447-LR-TC-P-IP 458-L-SLH-TC-P-IP 480-SLH-TC-P-IP 480-XLH-TC-P-IP 487-SLH-TC-P-IP 487-XLH-TC-P-IP 490-XLH-TC-P-IP 502-A-TC-P-IP 532-BR-TC-P-IP 537-L-TC-P-IP 546-B-TC-P-IP 547-RS-WS-TC-P-IP 548-H2-IP 554-L-TC-P-IP 562-L-TC-P-IP 564-L-TC-P-IP 573-L-TC-P-IP 588-L-TC-P-IP 627-LH-TC-P-IP 697-L-TC-P-IP 754-L-TC-P-IP 798-XLH-TC-P-IP 806-SLH-TC-P 822-BR-TC-P-IP 827-SLH-TC-P 828-BR-TC-P-IP 881-BR-TC-P-IP 930-K-TC-P-IP 937-K-TC-P-IP 957-S-TC-P-IP 960-VLH-TC-P-IP Length 86071 86073 86078 86080 86085 86105 86110 86123 86132 86137 86144 86158 86164 86167 86171 86173 86176 86185 86206 86208 86222 86227 86231 86240 86243 86245 86251 86253 86264 86287 86341 86351 86359 86372 86378 86381 86396 86402 86411 86430 86432 Exit Catalog Number Quantity GE Product Code Black/White Quantity LEAD LENGTHS Black F30T12 AND F30T12/WM LAMPS L 61.5 GE Lamp Product Line Catalog Code Qty. Descr. Volts Number F40T12/WM - High Power Factor 86101 1 Rapid 120 412-L-SLH-TC-P-IP★ • 86158 1 Rapid 277 458-L-SLH-TC-P-IP★ • 86110 2 Hybrid 120 420-L-TC-P-IP◆ • 86137 2 Rapid 120 446-L-SLH-TC-P • 86123 2 Rapid 277 443-L-SLH-TC-P • 86208 2 Hybrid 277 537-L-TC-P-IP◆ • F40T12/WM - Normal Power Factor 86105 1 Rapid 120 413-C-TC-P-IP❉ Certification • • • • • • • • • • • • • • • • • • • • • • • • • Input Power Ballast (Watts) Factor Min. F/C Start Sound Wiring Temp Rating Diag. Dim. .38 .17 .50 .65 .28 .26 44 44 59 74 74 70 .88 .88 .80 .90 .90 .91 2.00 2.00 1.36 1.22 1.22 1.30 < 1.9 < 1.85 < 1.9 < 1.9 < 1.9 < 1.9 < 20 < 20 < 20 < 20 < 20 < 20 60/15 60/15 60/15 60/15 60/15 60/15 A A A A A A 42 42 1 1 1 1 D2 D2 D2 D2 D2 D2 .61 33 .68 2.06 < 1.9 < 20 60/15 A 8 D1 ★ Not for use with “U” lamps ◆ Not for use with Energy Saver “U” lamps ❉ For Residential Use Only DIMENSIONS H M L W Overall Dimensions Draw # L D1 6 7/16 D2 9 1/2 W 1 7/8 2 3/8 Mounting Dimensions H M X 1 1/2 6 1 1/2 8 57/64 1 11/16 D 2-8 transforming the power of light ™ For For more more information, information, visit visit www.gelighting.com www.gelighting.com 2-9 2-9 ELECROMAGNETIC FLUORESCENT BALLASTS ELECROMAGNETIC FLUORESCENT BALLASTS FOR F40T10 LAMPS F40T12/U LAMPS GE Lamp Product Code Qty. Descr. F40T12/U - High Power Factor 86110 2 Hybrid 86137 2 Rapid 86208 2 Hybrid 86123 2 Rapid Certification Line Volts Catalog Number 120 120 277 277 420-L-TC-P-IP◆ 446-L-SLH-TC-P 537-L-TC-P-IP◆ 443-L-SLH-TC-P Line Current (Amps) NOM • • • • • • • • • • • • • • • • .64 .76 .32 .34 • • Input Power Ballast (Watts) Factor 74 90 87 92 .83 .93 .94 .95 Ballast Efficacy Crest Factor Factor 1.12 1.03 1.08 1.03 THD % < 1.7 < 1.7 < 1.7 < 1.7 < 32 < 20 < 20 < 20 Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. 50/10 50/10 50/10 50/10 A A A A 1 1 1 1 Dim. D2 D2 D2 D2 GE Lamp Product Line Code Qty. Descr. Volts F40T10 - High Power Factor 86101 1 Rapid 120 86158 1 Rapid 277 86110 2 Hybrid 120 86137 2 Rapid 120 86123 2 Rapid 277 86208 2 Hybrid 277 Certification Catalog Number 412-L-SLH-TC-P-IP 458-L-SLH-TC-P-IP 420-L-TC-P-IP 446-L-SLH-TC-P 443-L-SLH-TC-P 537-L-TC-P-IP Line Current (Amps) NOM • • • • • • • • • • • • • • • • • • • • • • • • • • .45 .19 .65 .76 .33 .32 • • Input Power Ballast (Watts) Factor 52 51 74 90 90 85 .90 .90 .85 .95 .95 .95 Ballast Efficacy Crest Factor Factor 1.73 1.76 1.15 1.06 1.06 1.12 < 1.7 < 1.7 < 1.7 < 1.7 < 1.7 < 1.7 THD % < 20 < 20 < 32 < 20 < 20 < 20 Min. F/C Start Sound Wiring Temp Rating Diag. 50/10 50/10 50/10 50/10 50/10 50/10 A A A A A A 42 42 1 1 1 1 Dim. D2 D2 D2 D2 D2 D2 ◆ Not for use with Energy Saver “U” lamps GE Lamp Product Line Catalog Code Qty. Descr. Volts Number F40T12/WM/U - High Power Factor 86137 2 Rapid 120 446-L-SLH-TC-P 86123 2 Rapid 277 443-L-SLH-TC-P F48”25W/UTLS & WORKLITE - Normal Power Factor 86105 1 Rapid 120 413-C-TC-P-IP❉ Certification • • • • • • • • • • NOM Line Current (Amps) Input Power Ballast (Watts) Factor Min. F/C Start Sound Wiring Temp Rating Diag. • • .65 .28 74 74 .90 .90 1.22 1.22 < 1.9 < 1.9 < 20 < 20 60/15 60/15 A A 1 1 D2 D2 • .51 32 .90 2.79 < 1.7 < 20 50/10 A 8 D1 Dim. T10 T12 FOR F40T12/WM/U, F48" 25W/UTLS AND WORKLITE 25 LAMPS ❉ For Residential Use Only DIMENSIONS H M L W Overall Dimensions Draw # L D1 6 7/16 D2 9 1/2 W 1 7/8 2 3/8 D 2-10 transforming the power of light ™ Mounting Dimensions H M X 1 1/2 6 1 1/2 8 57/64 1 11/16 DIMENSIONS Overall Dimensions Draw # L D2 9 1/2 H W 2 3/8 Mounting Dimensions H M X 1 1/2 8 57/64 1 11/16 M L W D For more information, visit www.gelighting.com 2-11 ELECROMAGNETIC FLUORESCENT BALLASTS ELECROMAGNETIC FLUORESCENT BALLASTS FOR F24, F30, F36 AND F42T12HO LAMPS GE Lamp Product Line Code Qty. Descr. Volts F24T12HO - High Power Factor 86174 2 Rapid 120 86264 2 Rapid 277 F36T12HO - High Power Factor 86174 2 Rapid 120 86264 2 Rapid 277 F42T12HO - High Power Factor 86174 2 Rapid 120 86264 2 Rapid 120 FOR F72T12HO LAMPS Certification Catalog Number Line Current (Amps) NOM Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. 490-XLH-TC-P 627-LH-TC-P-IP • • • • .95 .40 103 103 .81 .94 0.79 0.91 < 2.0 < 1.9 > 32 < 32 -20/-29 50/10 B B 1 1 D7 D6 490-XLH-TC-P 627-LH-TC-P-IP • • • • 1.06 .48 121 128 .84 .98 0.69 0.77 < 2.0 < 1.7 < 32 < 20 50/10 50/10 B B 1 1 D7 D6 490-XLH-TC-P 627-LH-TC-P-IP • • • • 1.12 .51 130 139 .86 .98 0.66 0.71 < 2.0 < 1.7 < 32 < 20 50/10 50/10 B B 1 1 D7 D6 GE Lamp Product Line Code Qty. Descr. Volts F72T12HO - High Power Factor 86174 1 Rapid 120 86164 2 Rapid 120 86167 2 Rapid 120 86174 2 Rapid 120 86171 2 Rapid 277 86173 2 Rapid 277 Certification Catalog Number 490-XLH-TC-P 480-SLH-TC-P-IP 480-XLH-TC-P-IP 490-XLH-TC-P 487-SLH-TC-P-IP 487-XLH-TC-P-IP NOM • • • • • • • • • • • • • • • • • • Line Current (Amps) .95 1.69 1.69 1.50 .74 .78 Input Power Ballast (Watts) Factor 107 196 196 177 197 208 .86 .97 .97 .92 .96 .95 Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. < 2.0 < 1.9 < 1.9 < 1.7 < 1.7 < 1.7 > 32 < 20 < 20 < 10 < 20 < 20 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. 0.80 0.49 0.49 0.52 0.48 0.46 B B B B B B 15 1 1 1 1 1 Dim. D7 D7 D7 D7 D7 D7 ✜ Power Factor Corrected to >85% FOR F72T12HO LAMPS GE Lamp Product Line Code Qty. Descr. Volts F48T12HO - High Power Factor 86174 1 Rapid 120 86174 2 Rapid 120 86264 2 Rapid 277 Certification Catalog Number 490-XLH-TC-P▼ 490-XLH-TC-P 627-LH-TC-P-IP Line Current (Amps) NOM • • • • • • .82 1.18 .55 Input Power Ballast (Watts) Factor 82 139 150 .81 .87 .99 Ballast Efficacy Crest Factor Factor 0.99 0.63 0.66 < 2.0 < 2.0 < 1.7 THD % Min. F/C Start Sound Wiring Temp Rating Diag. > 32 < 20 < 20 -20/-29 -20/-29 50/10 B B B 15 1 1 Dim. D7 D7 D6 ▼ Power Factor Corrected to >70% Certification Catalog Number Line Current (Amps) NOM Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. 490-XLH-TC-P▼ 490-XLH-TC-P 627-LH-TC-P-IP • • • • • • .80 1.07 .49 76 124 131 .78 .83 .92 1.03 0.67 0.70 < 2.0 < 2.0 < 1.9 > 32 < 32 < 20 60/15 60/15 60/15 B B B 15 1 1 D7 D7 D6 490-XLH-TC-P 490-XLH-TC-P • • • • .92 1.42 99 169 .83 .89 0.84 0.53 < 2.0 < 2.0 > 32 < 20 -20/-29 -20/-29 B B 15 1 D7 D7 FOR F60 AND F64T12HO LAMPS Certification Catalog Number 490-XLH-TC-P 490-XLH-TC-P Line Current (Amps) NOM • • • • .93 1.50 Input Power Ballast (Watts) Factor 101 178 .84 .89 Ballast Efficacy Crest Factor Factor 0.83 0.50 < 1.9 < 1.9 THD % Min. F/C Start Sound Wiring Temp Rating Diag. > 32 < 20 -20/-29 -20/-29 B B 15 1 NOM • Line Current (Amps) • 1.89 Input Power Ballast (Watts) Factor 224 1.06 0.47 < 1.7 < 20 50/10 B 1 Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. < 1.9 < 1.9 < 1.9 < 1.9 < 20 < 20 < 20 < 20 -20/-29 -20/-29 -20/-29 -20/-29 Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. D7 Certification Catalog Number 480-SLH-TC-P-IP 480-XLH-TC-P-IP 487-SLH-TC-P-IP 487-XLH-TC-P-IP NOM • • • • • • • • • • • • • • Line Current (Amps) 1.87 1.98 .87 .89 Input Power Ballast (Watts) Factor 220 235 235 244 .93 .93 .97 .95 0.42 0.40 0.41 0.39 B B B B 1 1 1 1 Dim. D7 D7 D7 D7 Dim. ▼ Power Factor Corrected to >70% GE Lamp Product Line Code Qty. Descr. Volts F64T12HO - High Power Factor 86174 1 Rapid 120 86174 2 Rapid 120 Certification FOR F84T12HO LAMPS GE Lamp Product Line Code Qty. Descr. Volts F84T12HO - High Power Factor 86164 2 Rapid 120 86167 2 Rapid 120 86171 2 Rapid 277 86173 2 Rapid 277 FOR F48T12HO/WM AND F60T12HO LAMPS GE Lamp Product Line Code Qty. Descr. Volts F48T12HO/WM - High Power Factor 86174 1 Rapid 120 86174 2 Rapid 120 86264 2 Rapid 277 F60T12HO - High Power Factor 86174 1 Rapid 120 86174 2 Rapid 120 GE Lamp Product Line Catalog Code Qty. Descr. Volts Number F72T12HO - High Power Factor - Tanning 86351 2 Rapid 120 798-XLH-TC-P-IP T12HO T12HO FOR F48T12HO LAMPS Dim. D7 D7 FOR F96T12HO AND F96T12HO/WM LAMPS GE Lamp Product Line Code Qty. Descr. Volts F96T12HO - High Power Factor 86174 1 Rapid 120 86164 2 Rapid 120 86167 2 Rapid 120 86171 2 Rapid 277 86173 2 Rapid 277 F96T12HO/WM - High Power Factor 86174 1 Rapid 120 86164 2 Rapid 120 86167 2 Rapid 120 86171 2 Rapid 277 86173 2 Rapid 277 Certification Catalog Number 490-XLH-TC-P 480-SLH-TC-P-IP 480-XLH-TC-P-IP 487-SLH-TC-P-IP 487-XLH-TC-P-IP 490-XLH-TC-P 480-SLH-TC-P-IP 480-XLH-TC-P-IP 487-SLH-TC-P-IP 487-XLH-TC-P-IP NOM • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Line Current (Amps) Input Power Ballast (Watts) Factor Dim. 1.10 1.99 2.15 .87 .95 124 237 250 237 261 .85 .96 .96 .95 .97 0.65 0.41 0.39 0.40 0.37 < 2.0 < 1.7 < 1.7 < 1.7 < 1.7 < 20 < 10 < 10 < 10 < 10 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 B B B B B 15 1 1 1 1 D7 D7 D7 D7 D7 .94 1.72 1.80 .75 .83 106 202 209 205 223 .81 .89 .89 .91 .92 0.76 0.44 0.43 0.44 0.41 < 2.0 < 1.9 < 1.9 < 1.9 < 1.9 < 32 < 20 < 20 < 20 < 20 60/15 60/15 60/15 60/15 60/15 B B B B B 15 1 1 1 1 D7 D7 D7 D7 D7 See product overview pages for electromagnetic fluorescent ballasts for additional information on weatherproof applications. DIMENSIONS H M L W Overall Dimensions Draw # L D6 11 3/4 D7 11 3/4 W 3 1/8 3 3/16 D 2-12 transforming the power of light ™ Mounting Dimensions H M 1 25/32 11 9/64 2 5/8 11 9/64 DIMENSIONS H X 2 2 M L W Overall Dimensions Draw # L D7 11 3/4 W 3 3/16 Mounting Dimensions H M 2 5/8 11 9/64 X 2 D For more information, visit www.gelighting.com 2-13 ELECROMAGNETIC FLUORESCENT BALLASTS ELECROMAGNETIC FLUORESCENT BALLASTS FOR F96PG17 AND F96PG17/WM LAMPS FOR F48PG17 AND F48T12VHO LAMPS GE Lamp Product Line Code Qty. Descr. Volts F48PG17 - High Power Factor 86432 2 Rapid 120 F48T12VHO - High Power Factor 86432 2 Rapid 120 Certification Catalog Number NOM Line Current (Amps) Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. 960-VLH-TC-P-IP① • • 1.60 175 .70 0.40 < 2.0 < 32 -20/-29 C 1 D8 960-VLH-TC-P-IP① • • 1.62 185 .72 0.39 < 2.0 < 32 -20/-29 C 1 D8 ① May be used with equivalent T10 or T10J lamps. GE Lamp Product Line Code Qty. Descr. Volts F96PG17 - High Power Factor 86430 1 Rapid 277 86402 2 Rapid 120 86411 2 Rapid 277 F96PG17/WM - High Power Factor 86430 1 Rapid 277 Certification Catalog Number NOM Line Current (Amps) Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. 957-S-TC-P-IP 930-K-TC-P-IP❷ 937-K-TC-P-IP❷ • • • • • • .83 3.83 1.61 192 446 429 .79 .98 .95 0.41 0.22 0.22 < 1.9 < 1.7 < 1.7 < 32 < 20 < 20 -20/-29 -20/-29 -20/-29 C D D 12 1 1 D8 D8 D8 957-S-TC-P-IP • • .79 175 .76 0.43 < 1.9 < 32 60/15 C 12 D8 THD % Min. F/C Start Sound Wiring Temp Rating Diag. ❷ Cannot be used with T10 or T10J lamps GE Lamp Product Line Code Qty. Descr. Volts F72PG17 - High Power Factor 86430 1 Rapid 277 86402 2 Rapid 120 86432 2 Rapid 120 86411 2 Rapid 277 F72T12VHO - High Power Factor 86430 1 Rapid 277 86402 2 Rapid 120 86432 2 Rapid 120 86411 2 Rapid 277 Certification Catalog Number NOM Line Current (Amps) Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. FOR F96T12VHO AND F96T12VHO/WM LAMPS Dim. 957-S-TC-P-IP▼ 930-K-TC-P-IP❷ 960-VLH-TC-P-IP① 937-K-TC-P-IP❷ • • • • • • • • .76 3.05 2.01 1.26 157 360 239 341 .77 .95 .72 .92 0.49 0.26 0.30 0.27 < 1.9 < 1.7 < 1.9 < 1.7 > 32 < 20 < 20 < 20 -20/-29 -20/-29 -20/-29 -20/-29 C D C D 12 1 1 1 D8 D8 D8 D8 957-S-TC-P-IP▼ 930-K-TC-P-IP❷ 960-VLH-TC-P-IP① 937-K-TC-P-IP❷ • • • • • • • • .75 3.05 2.08 1.26 161 360 248 341 .79 .95 .79 .91 0.49 0.26 0.32 0.27 < 1.9 < 1.7 < 1.9 < 1.7 > 32 < 20 < 20 < 20 -20/-29 -20/-29 -20/-29 -20/-29 C D C D 12 1 1 1 D8 D8 D8 D8 GE Lamp Product Line Code Qty. Descr. Volts F96T12VHO - High Power Factor 86430 1 Rapid 277 86402 2 Rapid 120 86411 2 Rapid 277 F96T12VHO/WM - High Power Factor 86430 1 Rapid 277 Certification Catalog Number NOM Line Current (Amps) Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor Dim. 957-S-TC-P-IP▼ 930-K-TC-P-IP❷ 937-K-TC-P-IP❷ • • • • • • .81 4.10 1.64 197 482 450 .78 .99 .95 0.40 0.21 0.21 < 1.9 < 1.7 < 1.7 < 32 < 20 < 20 -20/-29 -20/-29 -20/-29 C D D 12 1 1 D8 D8 D8 957-S-TC-P-IP▼ • • .79 183 .77 0.42 < 1.9 < 32 60/15 C 12 D8 T12VHO T12VHO FOR F72PG17 AND F72T12VHO LAMPS ▼ Power Factor Corrected to >70% ❷ Cannot be used with T10 or T10J lamps ▼ Power Factor Corrected to >70% ❷ Cannot be used with T10 or T10J lamps ① May be used with equivalent T10 or T10J lamps See product overview pages for electromagnetic fluorescent ballasts for additional information on weatherproof applications. See product overview pages for electromagnetic fluorescent ballasts for additional information on weatherproof applications. DIMENSIONS H M L W Overall Dimensions Draw # L D8 14 5/16 W 3 3/16 D 2-14 transforming the power of light ™ Mounting Dimensions H M 2 5/8 13 3/4 DIMENSIONS H X 2 M L W Overall Dimensions Draw # L D8 14 5/16 W 3 3/16 Mounting Dimensions H M 2 5/8 13 3/4 X 2 D For more information, visit www.gelighting.com 2-15 ELECROMAGNETIC FLUORESCENT BALLASTS ELECROMAGNETIC FLUORESCENT BALLASTS FOR F96T12 AND F96T12/WM LAMPS GE Lamp Product Line Code Qty. Descr. Volts F24T12 - High Power Factor 86206 2 Instant 277 F36T12 - High Power Factor 86085 2 Instant 120 86206 2 Instant 277 F40T12 /IS - Bi Pin - High Power Factor 86085 2 Instant 120 86206 2 Instant 277 F42T12 - High Power Factor 86085 2 Instant 120 86206 2 Instant 277 F48T12 - High Power Factor 86085 2 Instant 120 86206 2 Instant 277 F48T12/WM - High Power Factor 86085 2 Instant 120 86206 2 Instant 277 Certification Catalog Number NOM 532-BR-TC-P-IP◗ • • 213-TC-P-IP 532-BR-TC-P-IP◗ • • • • • 213-TC-P-IP 532-BR-TC-P-IP • • • • 213-TC-P-IP 532-BR-TC-P-IP • • 213-TC-P-IP 532-BR-TC-P-IP 213-TC-P-IP 532-BR-TC-P-IP Line Current (Amps) Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. .29 60 .96 1.60 < 1.85 < 32 32 / 0 B 40 D6 .70 .34 77 75 .95 .93 1.24 1.24 < 1.85 < 1.85 > 32 < 32 50/10 32 / 0 B B 39 40 D10 D12 • .80 .37 94 94 .92 .92 0.98 0.98 < 1.85 < 1.85 < 20 < 32 50/10 32 / 0 B B 39 40 D10 D12 • • • .74 .34 86 84 .93 .94 1.09 1.11 < 2.0 < 1.85 < 32 < 32 50/10 32 / 0 B B 39 40 D10 D12 • • • • • .79 .35 95 95 .92 .96 0.89 1.01 < 1.85 < 1.85 < 20 < 32 50/10 32 / 0 B B 39 40 D10 D12 • • • • • .72 .32 80 82 .91 .94 1.14 1.15 < 2.0 < 2.0 < 32 < 32 60/15 60/15 B B 39 40 D10 D12 Ballast Efficacy Crest Factor Factor THD % GE Lamp Product Line Code Qty. Descr. Volts F96T12 - High Power Factor 86372 1 Instant 120 86381 1 Instant 277 86378 2 Instant 277 F96T12/WM - High Power Factor 86372 1 Instant 120 86381 1 Instant 277 86378 2 Instant 277 Certification Catalog Number 822-BR-TC-P-IP 828-BR-TC-P-IP 827-SLH-TC-P-IP 822-BR-TC-P-IP 828-BR-TC-P-IP 827-SLH-TC-P-IP NOM • • • • • • • • • • • • • • Line Current (Amps) • • • • • • Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. .84 .35 .58 96 93 158 .95 .93 .93 0.98 1.00 0.59 < 1.85 < 1.85 < 1.85 < 32 < 32 < 10 0/-18 0/-18 50/10 C C C 34 34 40 D6 D6 D12 .70 .30 .48 79 79 132 .90 .96 .89 1.14 1.22 0.67 < 2.0 < 2.0 < 2.0 < 32 < 32 < 20 60/15 60/15 60/15 C C C 34 34 40 D6 D6 D12 T12 SLIMLINE T12 SLIMLINE FOR F24 - F48T12 LAMPS ◗ Power Factor Corrected to >75% FOR F60 - F84T12 LAMPS GE Lamp Product Line Code Qty. Descr. Volts F60T12 - High Power Factor 86396 2 Instant 120 F64T12 - High Power Factor 86396 2 Instant 120 F72T12 - High Power Factor 86372 1 Instant 120 86381 1 Instant 277 86359 2 Instant 120 86396 2 Instant 120 86378 2 Instant 277 F84T12 - High Power Factor 86372 1 Instant 120 86381 1 Instant 277 86359 2 Instant 120 86378 2 Instant 277 Certification Catalog Number NOM Line Current (Amps) Input Power Ballast (Watts) Factor Min. F/C Start Sound Wiring Temp Rating Diag. Dim. 881-BR-TC-P-IP❏ • • .96 109 .84 0.77 < 1.85 < 32 0/-18 C 39 D6 881-BR-TC-P-IP❏ • • 1.05 119 .84 0.71 < 1.85 < 32 0/-18 C 39 D6 822-BR-TC-P-IP 828-BR-TC-P-IP 806-SLH-TC-P 881-BR-TC-P-IP 827-SLH-TC-P-IP • • • • • • • • • • • .72 .30 1.13 1.03 .49 81 78 133 120 135 .95 .92 1.01 .82 .93 1.17 1.18 0.76 0.69 0.69 < 1.85 < 1.85 < 1.85 < 1.85 < 1.85 < 32 < 32 < 20 < 32 < 20 0/-18 0/-18 50/10 0/-18 50/10 C C C C C 34 34 39 39 40 D6 D6 D6 D6 D12 • • • • • • • • • • .77 .33 1.26 .55 89 86 143 150 .96 .94 .95 .95 1.09 1.09 0.67 0.63 < 1.85 < 1.85 < 1.85 < 1.85 < 32 < 32 < 20 < 10 0/-18 0/-18 50/10 50/10 C C C C 34 34 39 40 D6 D6 D6 D12 822-BR-TC-P-IP 828-BR-TC-P-IP 806-SLH-TC-P 827-SLH-TC-P-IP • • • • • • • • • • • ❏ Use with any combination of F60T12 & F64T12 DIMENSIONS H M L W Overall Dimensions Draw # L D6 11 3/4 D10 9 29/64 D12 11 3/4 W 3 1/8 3 3/32 3 3/16 D 2-16 transforming the power of light ™ Mounting Dimensions H M X 1 25/32 11 9/64 2 1 25/32 8 57/64 1 11/16 1 25/32 11 9/64 2 DIMENSIONS H M L W Overall Dimensions Draw # L D6 11 3/4 D12 11 3/4 W 3 1/8 3 3/16 Mounting Dimensions H M 1 25/32 11 9/64 1 25/32 11 9/64 X 2 2 D For more information, visit www.gelighting.com 2-17 ELECROMAGNETIC FLUORESCENT BALLASTS ELECROMAGNETIC FLUORESCENT BALLASTS FOR F4 AND F6T5 LAMPS GE Lamp Product Line Catalog Code Qty. Descr. Volts Number FC6T9 (20 Watt) - Normal Power Factor 86071 1 Preheat 120 200-C-S-P-IP♣ 86073 1 Preheat 120 200-H2P-IP❶ 86227 1 Rapid 120 547-RS-WS-TC-P-IP FC8T9 (22 Watt) - Normal Power Factor 86071 1 Preheat 120 200-C-S-P-IP♣ 86073 1 Preheat 120 200-H2P-IP❶ 86227 1 Rapid 120 547-RS-WS-TC-P-IP✩ Certification Line Current (Amps) NOM Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. • • • • • • .40 .34 .64 29 20 27 1.01 .94 .90 3.47 4.66 3.30 < 1.7 < 1.7 < 1.7 <10 <10 < 10 50/10 50/10 50/10 A A A 28 21 29 D11 E1 D1 • • • • • • .24 .30 .60 22 20 30 .93 .83 .85 4.19 4.08 2.83 < 1.7 < 1.7 < 1.7 <10 <10 < 10 50/10 50/10 50/10 A A A 28 21 29 D11 E1 D1 Line Current (Amps) NOM Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. CIRCLINE 548-H2-IP❶ • • • .67 .67 .60 37 37 35 .91 .91 .68 2.44 2.44 1.97 < 1.7 < 1.7 < 1.7 <10 <10 < 20 50/10 50/10 50/10 A A A 22 28 29 D11 D11 D1 • • .55 33 .60 1.83 < 1.7 < 20 50/10 A 29 D1 ✩ Also available in White Cans ♣ Starter is built in as an integral component ❶ Requires Starter NOM • • Input Power Ballast (Watts) Factor .17 8 1.00 Ballast Efficacy Crest Factor Factor 12.5 THD % < 1.7 <10 Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. 50/10 A 21 Dim. E1 FOR F14T8 AND F14T12 LAMPS ♣ Starter is built in as an integral component ♠ Requires one circuit interrupting lamp holder ❶ Requires Starter • • • Line Current (Amps) ❶ Requires Starter Dim. FOR 32 AND 40 WATT LAMPS Certification Certification Catalog Number GE Lamp Product Line Code Qty. Descr. Volts F14T8 - Normal Power Factor 86071 1 Preheat 120 86073 1 Preheat 120 F14T12 - Normal Power Factor 86243 1 Preheat 277 86245 2 Preheat 120 86240 2 Preheat 277 F14T12 - Normal Power Factor 86071 1 Preheat 120 86073 1 Preheat 120 86222 1 Preheat 120 ✩ Also available in White Cans ♣ Starter is built in as an integral component ❶ Requires Starter GE Lamp Product Line Catalog Code Qty. Descr. Volts Number FC12T9 (32 Watt) - Normal Power Factor 86078 1 Preheat 120 202-B-TC-P-IP❶ 86080 1 Preheat 120 202-SB-TC-P-IP♣ 86132 1 Rapid 120 445-RS-WS-TC-P-IP✩ FC16T9 (40 Watt) - Normal Power Factor 86132 1 Rapid 120 445-RS-WS-TC-P-IP✩ GE Lamp Product Line Code Qty. Descr. Volts F4T5 - Normal Power Factor 86231 1 Preheat 120 Certification Catalog Number 200-C-S-P-IP♣ 200-H2-IP❶ • • • • 562-L-TC-P-IP 564-L-TC-P-IP 554-L-TC-P-IP • • • • • • 200-C-S-P-IP♣ 200-H2-IP❶ 546-B-TC-P-IP♠ • • • • • • NOM Line Current (Amps) • .42 .36 22 19 1.07 .99 4.89 5.15 < 1.7 < 1.7 <10 <10 50/10 50/10 A A 28 21 D11 E1 .11 .39 .17 28 45 45 .75 .79 .79 2.68 1.75 1.76 < 2.0 < 1.7 < 1.9 <32 <20 <20 50/10 50/10 50/10 A A A 12 1 1 D2 D2 D2 • • .43 .37 .66 22 20 30 1.11 .98 .86 4.96 4.85 2.87 < 1.7 < 1.7 < 1.7 <10 <10 <10 50/10 50/10 50/10 A A A 28 21 8 D11 E1 D1 NOM Line Current (Amps) Ballast Efficacy Crest Factor Factor THD % • Input Power Ballast (Watts) Factor Min. F/C Start Sound Wiring Temp Rating Diag. Dim. PREHEAT/TRIGGER FOR 20, 22 AND 32 WATT LAMPS FOR F15T8 LAMPS GE Lamp Product Code Qty. Descr. F15T8 - High Power Factor 86243 1 Preheat 86245 2 Preheat 86240 2 Preheat F15T8 - Normal Power Factor 86071 1 Preheat 86073 1 Preheat 86222 1 Preheat 86144 2 Preheat Certification Input Power Ballast (Watts) Factor Min. F/C Start Sound Wiring Temp Rating Diag. Line Volts Catalog Number 277 120 277 562-L-TC-P-IP 564-L-TC-P-IP 554-L-TC-P-IP • • • • • • • .12 .47 .20 28 51 51 .88 .91 .89 3.16 1.78 1.76 < 2.0 < 1.7 < 1.9 <32 <32 <20 50/10 50/10 50/10 A A A 12 1 1 D2 D2 D2 120 120 120 120 200-C-S-P-IP♣ 200-H2-IP❶ 546-B-TC-P-IP♠ 447-LR-TC-P-IP • • • • • • • • • • .36 .32 .55 .50 22 20 25 39 1.05 1.05 .89 .75 4.86 5.13 3.50 1.92 < 1.7 < 1.7 < 1.7 < 1.7 <10 <10 <10 <20 50/10 50/10 50/10 50/10 A A A A 28 21 8 1 D11 E1 D1 D3 Dim. ♣ Starter is built in as an integral component ♠ Requires one circuit interrupting lamp holder ❶ Requires Starter DIMENSIONS L M W H H M L W Overall Dimensions Draw # L D1 6 7/16 D11 6 7/16 E1 3 1/16 W 1 7/8 1 7/8 1 25/32 Mounting Dimensions H M 1 1/2 6 1 5/16 6 1 5/16 2 3/4 DIMENSIONS L X - M W H H M L W M L 3/32" Slots D 3/32" Slots W 1 7/8 2 3/8 2 3/8 1 7/8 1 25/32 Mounting Dimensions H M X 1 1/2 6 1 1/2 8 57/64 1 11/16 1 1/2 6 1 5/16 6 1 5/16 2 3/4 - D E 2-18 M L Overall Dimensions Draw # L D1 6 7/16 D2 9 1/2 D3 6 19/32 D11 6 7/16 E1 3 1/16 transforming the power of light ™ E For more information, visit www.gelighting.com 2-19 ELECROMAGNETIC FLUORESCENT BALLASTS ELECROMAGNETIC FLUORESCENT BALLASTS GE Lamp Product Code Qty. Descr. F15T12 - High Power 86243 1 Preheat 86245 2 Preheat 86240 2 Preheat F15T12 - Normal Power 86071 1 Preheat 86073 1 Preheat 86222 1 Preheaat 86144 2 Preheat F18T8 - Normal Power 86071 1 Preheat 86073 1 Preheat F19T8 - Normal Power 86071 1 Preheat 86073 1 Preheat Certification Line Volts Catalog Number 277 120 277 562-L-TC-P-IP 564-L-TC-P-IP 554-L-TC-P-IP • • • • • • • 120 120 120 120 200-C-S-P-IP♣ 200-H2-IP❶ 546-B-TC-P-IP♠ 447-LR-TC-P-IP • • • • • • • • • • 120 120 200-C-S-P-IP♣ 200-H2-IP❶ • • • • 120 120 200-C-S-P-IP♣ 200-H2-IP❶ • • • • Line Current (Amps) NOM Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. .11 .43 .20 28 44 49 .85 .85 .87 3.04 1.91 1.78 < 2.0 < 1.7 < 1.9 <32 <20 <20 50/10 50/10 50/10 A A A 12 1 1 D2 D2 D2 .41 .44 .61 .56 23 21 30 42 1.20 1.08 .96 .80 5.26 5.19 3.23 1.90 < 1.7 < 1.7 < 1.7 < 1.7 <10 <10 <10 <20 50/10 50/10 50/10 50/10 A A A A 28 21 8 1 D11 E1 D1 D3 • .33 .28 21 19 .91 .80 4.31 4.29 < 1.7 < 1.7 <10 <10 50/10 50/10 A A 28 21 D11 E1 • .31 .26 21 18 .91 .80 4.28 4.33 < 1.7 < 1.7 <10 <10 50/10 50/10 A A 28 21 D11 E1 ♣ Starter is built in as an integral component ❶ Requires Starter ♠ Requires one circuit interrupting lamp holder GE Lamp Product Line Code Qty. Descr. Volts F40T10 - Normal Power Factor 86078 1 Preheat/RS 120 86080 1 Preheat/RS 120 F40T12 - Normal Power Factor 86078 1 Preheat/RS 120 86080 1 Preheat/RS 120 F40T12/WM - Normal Power Factor 86078 1 Preheat/RS 120 86080 1 Preheat/RS 120 Certification Catalog Number Line Current (Amps) NOM Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. 202-B-TC-P-IP❶ 202-SB-TC-P-IP♣ • • • • .56 .56 38 38 .77 .77 2.05 2.05 < 1.7 < 1.7 <20 <20 50/10 50/10 A A 22 28 D11 D11 202-B-TC-P-IP❶ 202-SB-TC-P-IP♣ • • • • .60 .60 39 39 .77 .77 1.99 1.99 < 1.7 < 1.7 <10 <10 50/10 50/10 A A 22 28 D11 D11 202-B-TC-P-IP❶ 202-SB-TC-P-IP♣ • • • • .68 .68 37 37 .82 .82 2.22 2.22 < 1.9 < 1.9 <10 <10 60/15 60/15 A A 22 28 D11 D11 THD % Min. F/C Start Sound Wiring Temp Rating Diag. ♣ Starter is built in as an integral component ❶ Requires Starter DIMMING FOR F30T12 AND F40T12 LAMPS 60HZ FOR F20, F25, F30T12 AND F30T8 LAMPS GE Lamp Product Line Code Qty. Descr. Volts F20T12 - High Power Factor 86243 1 Preheat 277 86245 2 Preheat 120 86240 2 Preheat 277 F20T12 - Normal Power Factor 86071 1 Preheat 120 86073 1 Preheat 120 86222 1 Preheat 120 86144 2 Preheat 120 F30T8 - Normal Power Factor 86078 1 Preheat 120 86080 1 Preheat 120 F30T12 - Normal Power Factor 86078 1 Preheat/RS 120 86080 1 Preheat/RS 120 PREHEAT/TRIGGER FOR F40T10 AND F40T12 LAMPS PREHEAT/TRIGGER & DIMMING PREHEAT/TRIGGER FOR F15T12, F18T8 AND F19T8 LAMPS Certification Catalog Number Line Current (Amps) NOM Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. 562-L-TC-P-IP 564-L-TC-P-IP 554-L-TC-P-IP • • • • • • • .12 .51 .22 30 55 55 .81 .85 .86 2.73 1.55 1.55 < 1.9 < 1.7 < 1.7 <32 <20 <20 50/10 50/10 50/10 A A A 12 1 1 D2 D2 D2 200-C-S-P-IP♣ 200-H2-IP❶ 546-B-TC-P-IP♠ 447-LR-TC-P-IP • • • • • • • • • • .35 .30 .58 .43 23 20 29 37 .95 .83 .82 .56 4.15 4.15 2.83 1.51 < 1.7 < 1.7 < 1.7 < 1.7 <10 <10 <10 <20 50/10 50/10 50/10 50/10 A A A A 28 21 8 1 D11 E1 D1 D3 202-B-TC-P-IP❶ 202-SB-TC-P-IP♣ • • • • .62 .62 37 39 .97 2.97 2.62 7.62 < 1.7 < 1.7 <10 <10 50/10 50/10 A A 22 28 D11 D11 202-B-TC-P-IP❶ 202-SB-TC-P-IP♣ • • • • .68 .68 37 37 .85 .85 2.28 2.28 < 1.7 < 1.7 <10 <10 50/10 50/10 A A 22 28 D11 D11 GE Lamp Product Line Code Qty. Descr. Volts F40T12 - High Power Factor 86185 2 @ 100% 120 86185 2 @ 20% 120 F30T12 - Corrected Power Factor 86185 2 @ 100% 120 86185 2 @ 20% 120 Certification Catalog Number NOM Line Current (Amps) Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor Dim. 502-A-TC-P-IP✝➑ 502-A-TC-P-IP✝➑ • • • • .85 .68 94 35 .88 .20 0.94 0.57 < 1.7 < 1.7 < 20 < 32 50/10 50/10 A A 18 18 D5 D5 502-A-TC-P-IP➑➂ 502-A-TC-P-IP➑➁ • • • • .87 .58 83 27 .89 .21 1.07 0.77 < 1.7 < 1.9 < 20 < 32 50/10 50/10 A A 18 18 D5 D5 ✝ Requires two circuit interrupting lamp holder ➑ UL component recognized for use with specific Dimming Controls ➁ Power Factor Corrected to <60% ➂ Power Factor Corrected to >60% ♣ Starter is built in as an integral component ❶ Requires Starter ♠ Requires one circuit interrupting lamp holder DIMENSIONS L M W H H M L W M L 3/32" Slots Overall Dimensions Draw # L D1 6 7/16 D2 9 1/2 D3 6 19/32 D11 6 7/16 E1 3 1/16 W 1 7/8 2 3/8 2 3/8 1 7/8 1 25/32 Mounting Dimensions H M X 1 1/2 6 1 1/2 8 57/64 1 11/16 1 1/2 6 1 5/16 6 1 5/16 2 3/4 - DIMENSIONS H M L W Overall Dimensions Draw # L D11 6 7/16 D5 16 3/8 W 1 7/8 2 3/8 Mounting Dimensions H M X 1 5/16 6 1 1/2 15 25/32 1 11/16 D D E 2-20 transforming the power of light ™ For more information, visit www.gelighting.com 2-21 ELECROMAGNETIC FLUORESCENT BALLASTS ELECROMAGNETIC FLUORESCENT BALLASTS WIRING DIAGRAMS FOR F30T12 AND F40T12 LAMPS GE Lamp Product Line Catalog Code Qty. Descr. Volts Number F40T12 - High Power Factor 86341 2 Rapid 220/50Hz 754-L-TC-P-IP Certification Line Current (Amps) NOM • .43 Input Power Ballast (Watts) Factor 93 .94 Ballast Efficacy Crest Factor Factor 1.01 < 1.7 THD % < 20 Min. F/C Start Sound Wiring Temp Rating Diag. 50/10 A 1 Dim. Black White D2 Black White Yellow Yellow Line BALLAST BALLAST Blue Blue Red Red Black White Blue Blue Yellow Yellow Line Red Red Blue BALLAST Blue/White Blue/White Red Red LAMP LAMP LAMP LAMP LAMP LAMP Use disconnect lampholder only DIAGRAM 1 EXPORT FOR F40T12/U, F40T12/WM AND F40T12/WM/U LAMPS GE Lamp Product Line Catalog Code Qty. Descr. Volts Number F40T12/WM - High Power Factor 86341 2 Rapid 220/50Hz 754-L-TC-P-IP Certification Line Current (Amps) NOM Input Power Ballast (Watts) Factor Ballast Efficacy Crest Factor Factor THD % Min. F/C Start Sound Wiring Temp Rating Diag. DIAGRAM 8 Dim. Red Red Black • .37 77 .87 1.13 < 1.9 < 32 60/15 A 1 DIAGRAM 11 White D2 Black White Blue Blue Line Brown BALLAST Red Red BALLAST DIMMER Black White Blue/White Blue Blue Yellow Yellow Blue BALLAST Yellow Yellow Red Red WIRING DIAGRAMS Line LAMP LAMP Black FOR F40T10 LAMPS GE Lamp Product Line Catalog Code Qty. Descr. Volts Number F40T10 - High Power Factor 86341 2 Rapid 220/50Hz 754-L-TC-P-IP LAMP LAMP Certification Line Current (Amps) NOM • .43 Input Power Ballast (Watts) Factor 95 .93 Ballast Efficacy Crest Factor Factor 0.98 < 1.7 THD % < 20 Min. F/C Start Sound Wiring Temp Rating Diag. 50/10 A 1 Line White Line INSULATE EACH YELLOW LEAD INDIVIDUALLY Use disconnect lampholder only Dim. DIAGRAM 12 D2 DIAGRAM 15 S DIAGRAM 18 S S Line LAMP Black BALLAST Black White Blue BALLAST Yellow LAMP Black Blue White Black Red White BALLAST LAMP Mount lamp within 1/2" of grounded metal reflector Line Diagram 21 DIAGRAM 21 DIMENSIONS Overall Dimensions Draw # L D2 9 1/2 H W 2 3/8 DIAGRAM 22 DIAGRAM 28 Mounting Dimensions H M X 1 1/2 8 57/64 1 11/16 M L W D 2-22 transforming the power of light ™ For more information, visit www.gelighting.com 2-23 ELECROMAGNETIC FLUORESCENT BALLASTS WIRING DIAGRAMS Red Red Blue White Black Line BALLAST White LAMP LAMP LAMP White BALLAST Red Blue Black Black BALLAST White Red Line Line Metal contacts lamp to fixture WIRING DIAGRAMS DIAGRAM 29 Red Red LAMP DIAGRAM 34 Blue Blue LAMP Yellow Yellow LAMP DIAGRAM 35 Red Red Blue Blue LAMP Line BALLAST LAMP BALLAST White White Black Black Line Lamps must be mounted within one inch of a grounded metal reflector, cover of the ballast channel or grounded metal strip at least one-inch wide over the full length of the lamp. DIAGRAM 36 DIAGRAM 37 Black LAMP Line LAMP Brown Brown White Black BALLAST Blue Blue LAMP Line DIAGRAM 40 2-24 White Red Red Blue Red BALLAST Red Blue White Black Line Lamps must be mounted within one inch of a grounded metal reflector, cover of the ballast channel or grounded metal strip at least one-inch wide over the full length of the lamp. BALLAST DIAGRAM 42 transforming the power of light ™ DIAGRAM 39 SIGN ILLUMINATING BALLASTS A COMPLETE RANGE OF SOLUTIONS... FROM THE NAME YOU TRUST SIGN ILLUMINATING BALLASTS GE’s high-output ballasts are great for rugged outdoor sign cabinet applications because they provide reliable low-temperature starting—as low as -20°F. And all GE sign ballasts offer Class P thermal protection. Our range of sign ballasts: • Offers proven reliability • Is ideal for high-moisture environments • Supports applications from 1-6 lamps and 2-48 ft. GE offers the convenience of one-stop shopping not just for sign ballasts but for HID, linear fluorescent, and all your other ballast needs. GE sign ballasts provide ultra-reliable low-temperature starting – plus Class P thermal protection. For more information, visit www.gelighting.com 3-1 SIGN ILLUMINATING BALLASTS SIGN ILLUMINATING BALLASTS APPLICATION AND OPERATING INFORMATION Heat Ballasts generate heat during normal operation. By design, fluorescent ballasts should operate so that their maximum hot-spot case temperature does not exceed 90°C (194°F). Operating at higher temperatures will shorten ballast life or may cause the thermal protection circuit to trip. The temperature the ballast reaches depends on the temperature of the area surrounding it – plus the heatconducting surface touching the ballast. Ballasts should be installed in a manner that avoids future overheating. To maintain normal ballast temperature, you should: 1. Mount the ballast against a flat surface of heavy gauge metal such as the structural part of the sign. 2.Keep the ballast as far away as possible from other ballasts, lamps or reflective surfaces. (Lamps generate approximately three-fourths of the heat in a plastic sign). The ends of the lamps are the hottest part, so you should mount the ballast as far away from the ends as possible. 3.Paint the inside of the sign with flat white paint. Moisture Protection 1. Vent the sign as well as possible without allowing water to enter. 2. Ballasts should be mounted horizontally (except for weatherproof types). If the ballast must be mounted vertically, allow room for sufficient air circulation. Wherever possible, mount the ballast in an enclosure outside the sign by using GE pup tents. You can get pup tents at no charge when you order the plastic sign ballast. Your wholesaler will also have a supply for your convenience. Grounding The white lead of a 120-volt ballast must be connected to the neutral or ground side of the power supply. All metal parts of the sign, as well as the ballast case, must be grounded either through the conduit which holds the power supply or by direct connection with a grounding wire. An underground sign is a potential hazard – and it can give misleading symptoms when looking for sign faults. Proper Lamp Life and Starting In rapid-start installations, proper filament heating is necessary for reliable starting and normal lamp life. To ensure that proper heating is taking place, the following steps are recommended: 1. Lamp leads should be kept as short as possible and with a minimum of splices. 2. All connections should be soldered. 3. Maintain proper alignment and spacing of lamp holders to ensure good contact in the sockets. 4. Mount lamps within one inch of grounded metal. This is one lamp manufacturer's published requirement for eliable starting. 3-2 Flashing Rapid-start lamps may be flashed without reduction in lamp life by using ballasts which are specifically designed for this operation. These ballasts are designed with slightly higher filament voltages that the conventional ballast to ensure satisfactory lamp life. Instantstart lamps cannot be flashed. CAUTION: Use only one flasher contact per ballast. Light Output vs. Temperature The light output of a fluorescent lamp varies according to the mercury vapor pressure inside the lamp. This pressure is controlled by the coldest spot on the bulb wall. The ballast may start the lamp, but the light output can be very low as the bulb wall temperature is low. Several factors influence this, including ambient temperatures, wind, type of enclosure, etc. If maximum light output is critical, consult a lamp manufacturer for advice. Lamp Starting Problems Occasionally a field problem will arise involving improper lamp starting. The usual complaint is that the lamps start slowly (or not at all). Here are some of the causes: 1. Low line voltage 2. Improper sign grounding 3. Insufficient or no filament voltage 4. Insufficient or no open circuit voltage 5. Dirty lamps during high-humidity operating conditions 6. Lamps improperly inserted in the sockets. If lamp starting is a problem in your installation, check the sign grounding, filament voltage (3.4-3.9 volts), and open circuit voltage. If all are normal, the probable cause is dirty lamps. The lamps should be washed in clean water, drip-dried, and reinstalled. If this doesn't solve the problem, contact your nearest GE representative for further assistance. Short Lamp Life If the lamp has not given proper length of service as specified by the lamp manufacturer, the following reasons for early failure should be considered: 1. Improper starting due to insufficient filament voltage 2. Frequent starting and short operating periods 3. Improper ballast 4. Improper voltage supply 5. Faulty wiring 6. Defective lamps 7. Lamps improperly inserted in sockets Early lamp failure will be preceded by a dense blackening on either or both ends of the lamps. This blackening will extend three or four inches from the lamp base and should not be confused with a small dense spot, which is a mercury deposit that can occur at any time during lamp life. Dense blackening due to early lamp failure should not be confused with the gray bands that sometimes appear toward the end of normal lamp life (about two inches from either end of the lamp). transforming the power of light ™ STANDARD HIGH OUTPUT SIGN BALLASTS GE Product Code Catalog Number Total Lamp Footage Start Temp (°F) Max. Line Cur. Max. Input Watts Open Circuit Volt. Wiring Diagram Dimen. Chart Ref. Weight (lbs.) PLASTIC SIGN BALLASTS - HIGH OUTPUT 800mA RS LAMPS - 120 Volts - 60 Hz TWO LAMP BALLASTS 88921 USB-0412-12-IP 4´ min. - 12´ max. -20 1.35 160 500 1a, 2a 1 8 USB-0816-14-IP USB-1024-14-IP USB-1632-24-IP 8´ min. - 16´ max. 10´ min. - 24´ max. 16´ min. - 32´ max. -20 -20 -20 1.90 2.70 3.50 220 325 420 590 720 950 4a, 6a, 9, 1b 4a, 6a, 9, 1b 4a, 6a, 9 2 3 4 12 14 16 USB-2036-46-IP USB-2048-46-IP 20´ min. - 36´ max. 20´ min. - 48´ max. -20 -20 4.00 5.00 480 600 720 720 5a, 7, 7a 5a, 7, 7a 4 4 18 18 FOUR LAMP BALLASTS 88931 88936 88934 SIX LAMP BALLASTS 88939 88940 HIGH OUTPUT SIGN BALLASTS GE Product Code Catalog Number Total Lamp Footage Start Temp (°F) Max. Line Cur. Max. Input Watts Open Circuit Volt. Wiring Diagram Dimen. Chart Ref. Weight (lbs.) -20° -20° -20° 2.00 3.50 4.80 240 410 570 625 970 800 3, 4, 5, 6, 7, 8 3, 4, 5, 6, 7, 8 1, 2, 3, 4, 7, 8 3 3 5 15 16 18 MAX-3 HIGH OUTPUT SIGN BALLASTS 800mA RS LAMPS - 120 Volts - 60 Hz ONE TO SIX LAMP BALLASTS 88918 88920 88919 USB-0218-16-IP USB-1232-16-IP USB-1048-16-IP 2´ min. - 18´ max. 12´ min. - 32´ max. 10´ min. - 48´ max. See page 4-4 for Lead Lengths DIMENSIONS DIMENSION CHART Ref. # A 1 10 CM\nv˝ 2 10 CM\nv˝ 3 13C\zn˝ 4 15>\zn˝ 5 13>\zn˝ B 11VB\nv˝ 11VB\nv˝ 14B\zn˝ 16ZZ\zn˝ 16ZZ\zn˝ C 11>\nv˝ 11>\nv˝ 13C\v˝ 16Z\,˝ 16Z\,˝ D 1C\v˝ 2VC\nv˝ 2VC\nv˝ 2VC\nv˝ 2 VC\nv˝ HIGH OUTPUT SIGN BALLASTS APPLICATION AND OPERATING INFORMATION E 3C\zn˝ 3C\zn˝ 3C\zn˝ 3C\zn˝ 3C\zn˝ Diagrams Notes: Note 1: When operating a two-lamp ballast on one lamp insulate each yellow lead. Note 2: When operating a three-lamp ballast on two lamps insulate each yellow and blue/white lead. Note 3: When operating a four-lamp ballast on three lamps insulate each yellow blue/white, and brown lead. For more information, visit www.gelighting.com 3-3 SIGN ILLUMINATING BALLASTS SIGN ILLUMINATING BALLASTS PLASTIC SIGN BALLASTS LEAD LENGTHS (INCHES) GE Product Code Catalog Number White Black Blues WIRING DIAGRAMS Reds Yellows Browns Oranges Orange Blacks Blue Whites Red Whites LINE WHITE BLACK BLUE BLUE BALLAST RED RED YELLOW YELLOW LINE PLASTIC SIGN BALLASTS - HIGH OUTPUT 800mA RS LAMPS - 120 Volts - 60 Hz BLACK BLUE BLUE BROWN BROWN YELLOW YELLOW BALLAST RED RED BLUE/WHITE BLUE/WHITE TWO LAMP BALLASTS 88921 USB-0412-12-IP 24 24 38 38 48 36 24 24 24 24 24 65 79 80 40 48 54 39 75 60 56 83 80 88939 USB-2036-46-IP 24 24 50 88940 USB-2048-46-IP 24 24 80 MAX-3 HIGH OUTPUT SIGN BALLASTS 800mA RS LAMPS - 120 Volts - 60 Hz 80 80 70 70 38 50 FOUR LAMP BALLASTS 88931 88936 88934 LAMP USB-0816-14-IP USB-1024-14-IP USB-1632-24-IP 48 57 72 DIAGRAM 1 LAMP DIAGRAM 1A DIAGRAM 1B SIX LAMP BALLASTS 50 50 50 50 38 50 LINE ONE TO SIX LAMP BALLASTS 88918 88920 88919 USB-0218-16-IP USB-1232-16-IP USB-1048-16-IP 24 24 24 24 24 24 60 80 80 60 60 80 60 60 70 60 80 50 60 60 60 60 60 60 60 72 50 WHITE BLACK YELLOW YELLOW BALLAST RED RED BLUE BLUE LAMP 1 Note: Maximum volts above ground, any lead 590 volts. LAMP 2 DIAGRAM 2 DIAGRAM 2A DIAGRAM 3 SIGN BALLAST FOOTAGE LINE Fluorescent Sign Ballast Matrix No. of Lamps Per Ballast 1-2 TOTAL LAMP FOOTAGE REQUIRED WHITE BLACK BROWN BROWN YELLOW YELLOW BALLAST BLUE BLUE BLUE / WH BLUE / WH RED RED WIRING DIAGRAMS LEAD LENGTH & BALLAST FOOTAGE MOUNT LAMPS WITHIN 1˝ OF GROUNDED METAL REFLECTOR LAMP 4 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 LAMP 3 88921, USB-0412-12-IP LAMP 2 88931, USB-0816-14-IP 1-4 LAMP 1 MOUNT LAMPS WITHIN 1˝ OF GROUNDED METAL REFLECTOR 88936, USB-1024-14-IP 2-4 88934, USB-1632-24-IP DIAGRAM 4 88939, USB-2036-46-IP 4-6 DIAGRAM 4A DIAGRAM 5 88940, USB-2048-46-IP 88918, USB-0218-16-IP 1-6 LINE 88920, USB-1232-16-IP 88919, USB-1048-16-IP WHITE BLACK BROWN BROWN BLUE / WH BLUE / WH YELLOW YELLOW BALLAST BLUE BLUE ORANGE / BLK ORANGE / BLK ORANGE ORANGE RED RED LINE LAMP 1 LAMP 2 BLACK WHITE YELLOW YELLOW BROWN BROWN BALLAST RED RED BLUE / WH BLUE / WH BLUE BLUE LAMP 1 LAMP 3 LAMP 2 LAMP 4 LAMP 5 LAMP 3 LAMP 6 INDIVIDUALLY CAP THE YELLOW LEADS MOUNT LAMPS WITHIN 1˝ OF GROUNDED METAL REFLECTOR DIAGRAM 5A 3-4 transforming the power of light ™ DIAGRAM 6 DIAGRAM 6A For more information, visit www.gelighting.com 3-5 SIGN ILLUMINATING BALLASTS WIRING DIAGRAMS LINE BLACK WHITE BROWN BROWN BLUE / WH BLUE / WH YELLOW YELLOW BALLAST BLUE BLUE ORANGE / BLK ORANGE / BLK ORANGE ORANGE RED RED LAMP 1 LAMP 2 LAMP 4 LAMP 5 LAMP 6 INDIVIDUALLY CAP THE YELLOW LEADS WIRING DIAGRAMS DIAGRAM 7 3-6 DIAGRAM 7A DIAGRAM 8 DIAGRAM 9 transforming the power of light ™ COMPACT FLUORESCENT BALLASTS A COMPLETE RANGE OF SOLUTIONS FROM THE NAME YOU TRUST GE offers a full range of magnetic and electronic compact fluorescent ballasts. Our magnetic models come in a variety of shapes and sizes, from core and coils to High Power Factor potted ballasts with bottom exit leads and mounting studs for all downlighting applications. COMPACT FLUORESCENT BALLASTS Our newest electronic models offer installer-friendly universal input voltage, which reduces your inventory and ensures that you have the right voltage ballast every time. These models feature a low profile case that fits in any fixture. And their metal housing construction meets all plenum codes and delivers maximum heat transfer to extend ballast life. Our newest compact fluorescent models offer installer-friendly universal input voltage. For more information, visit www.gelighting.com 4-1 COMPACT FLUORESCENT BALLASTS COMPACT FLUORESCENT BALLASTS Electronic Compact Fluorescent Ballasts Electronic compact fluorescent ballasts from GE feature installer-friendly universal input voltage (108 to 305 Volts) and metal case designs for compliance with all plenum and construction code requirements. They also offer an end-of-life shutdown circuit with auto-reset that meets ANSI/NEMA requirements – a feature that eliminates lamp/socket damage while allowing you to replace failed lamps after shutdown without turning off the power. Our universal voltage compact fluorescent ballasts offer both one- and two-lamp operation–and they're ideal for a wide variety of downlight and surface mount applications for atriums, hotel corridors, offices, and outdoors. All models operate multiple lamp types for added versatility in many different applications. These ballasts are designed and manufactured for long life. Lamps can be mounted in close proximity to these ballasts because they have no temperature-critical UNDERSTANDING CFL TECHNOLOGY components near the can sides. And their circuit board potting enhances reliability by lowering case temperatures. All universal voltage compact fluorescent ballasts incorporate programmed rapid start (PRS) technology that increases lamp life for those frequently switched applications where occupancy sensors are used. PRS is recommended by all lamp manufacturers. For the Canadian market, we have new 347 Volt compact fluorescent models. These also offer outstanding reliability and lamp performance. These 347 Volt models are available for one- and two-lamp operation for lamps ranging from 13 to 70 watts. Magnetic Compact Fluorescent Ballasts GE offers a complete line of magnetic compact fluorescent ballasts, ranging from 5-40 watts (10-38 watts for 2D lamps). Both core & coil and F-Can models are available in a variety of configurations that include side exit (SE), bottom exit (BE) and bottom exit studs (BES). Compact fluorescent (CFL) lamps are single-ended and plug into sockets. They're sometimes referred to as “single-based” or “single-ended” fluorescent lamps. Lamp Shapes Today's CFL lamps come in these basic shapes: twin tube, quad, triple, multi and circular. Each of these shapes has its own subset of sizes. For example, the twin tube may range from 4" long (5 watt) to 22" long (40 watt). lamp base style is part of the ANSI/NEMA designation. In this catalog, GE CFL ballasts are classified according to lamp type. Icons representing each lamp type provide a quick visual reference. Within each classification, the lamps and their appropriate ballasts can be found by referring to the generic NEMA lamp descriptions. Lamp Designation There are two different industry-recognized nomenclatures for identifying CFL lamps: ANSI Lamp Designations and NEMA Lamp Designations. Here are examples of each: OR ANSI Designation OR Long Twin T5, 4-Pin 5w – 80w Twin, 2-Pin 5w – 13w 13W Lamp Wattage 7T4 Lamp Length Lamp Diameter OR 2-Pin 4-Pin Quad 9w – 27w Square (2D) 10w – 55w PRODUCT OVERVIEW Multiple, 4-Pin (Philips) 18w – 42w T5 Circular 22w - 55w Installer-friendly options for compact fluorescent lamps. Pins and Starters CFL lamps feature either two pins or four pins. Those with two pins have starters built into their bases, and they require a magnetic preheat ballast. The twopin CFL lamps are available in wattages from 5-28. Four-pin lamps are traditionally powered by electronic ballasts. These lamps do not have an internal starter, so the other filament terminals (pins) are made accessible for external connection to the ballasts. Note: GE offers both magnetic and electronic ballasts for the four-pin 32 and 26 watt lamps and all four-pin Long Twin T5 lamps. Lamp Bases There are a variety of lamp bases used with today's CFL lamps. This provides a safeguard to make sure that the proper lamp/ballast combination is installed. The 4-2 transforming the power of light ™ 1/8" Twin (T) Quad (Q) Multi (M) 2D (S) GX23 PH Base Starting: PH - Preheat RS - Rapid Start NEMA Designation CFT Twin (T) Quad (Q) Multi (M) 2D (S) Multiple, 4-Pin (GE & OSI) 18w – 70w T 13W GX23 Lamp Wattage Base Both lamp designations refer to lamp wattage, shape, and base type. Since the NEMA designation is shorter, it will probably be the nomenclature of choice in the future. All of the major lamp companies have trade names for various CFL lamp types, such as GE’s “Biax” and “2D” lamps, OSI’s “Dulux,” and Philips’ “PL.” These names have become more widely used than either of the industry designations. Industry Watts GE OSI Philips Single or Twin Low watt Biax Dulux S, S/E PL-S 5, 7, 9, 13 Double or Quad 9, 13, 18, 20, 26, 27 Double Biax Dulux D, D/E PL-C Multiple 13,18, 26, 32, 42 Biax T/E Dulux T T/E, T/E/IN PL-T Multiple 42,57,70 Biax Q/E Dulux T/E/IN PL-T High Lumen Biax Dulux L, F PL-L 2D __ __ __ Pentron Silhouette Long Twin 18, 24/27, T5 36/39, 40 50,80 Square 10, 16, 21, 28, 38,55 Circline 22, 40, 55 For more information, visit www.gelighting.com UNDERSTANDING CFL TECHNOLOGY PRODUCT OVERVIEW 4-3 COMPACT FLUORESCENT BALLASTS COMPACT FLUORESCENT BALLASTS TYPICAL SPECIFICATIONS FOR ELECTRONIC COMPACT FLUORESCENT BALLASTS UNDERSTANDING PART NUMBERS 4-4 19. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of manufacture. 20. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years. 21. Ballast shall be manufactured in an ISO 9001 Certified Facility. 22. GE model_________________________ (or approved equal). transforming the power of light ™ Lamp Wattage Our part number nomenclature for magnetic ballasts is shown below: UNV or 347V Color: 001-White 000-Black CXXX XX XXX XXX XXX X Odd = NPF Even = HPF Thermally Protected Color: 001 – White 000 – Black # of lamps SR-Series, Rapid Start R-Rapid Start 4XXX XX P XXX XXX X 1 – 120V 2 – 277V 3 – 347V F1 – Frame F2 – Fr. w/feet H2 – Cover/Fr. No suffix – Side Exit BE – Bottom Exit BES – Bottom Exit with Studs C – Carton T – Tray Pack Example: 4123PBES000T Ballast for CFL Lamps: Indicated by “4” prefix Voltage: 120V Lamp Type: 26W Quad Lamp (refer to catalog for wattage) Power Factor: Normal Encased and Potted: Indicated by absence of F1, F2, or H2 P: Thermally protected BES: Bottom exit leads with studs 000: Color — Black T: Packaging container style — Tray Pack These ballasts are available for a wide variety of applications with lamps, voltages, mounting configurations, and performance characteristics. For more detailed information, just identify the lamps to be ballasted and work forward to determine the ballast part number. Electronic Our nomenclature for electronic CFL ballasts follows the system already in place for other electronic ballasts. The exceptions are that the model number prefix for compact fluorescent is a C rather than a B—and the suffixes for the mounting configuration will be the same as those used for magnetic products (BE and BES). If you don't see these suffixes, the ballast has traditional side exit leads. No suffix or SE – Side Exit BE – Bottom Exit BES – Bottom Exit with Studs C-Carton T-Tray Pack I-Individual Example: Electronic C240PUNVHP-B Ballast Type: C — CFL Electronic Ballast Lamp Qty: 2 Lamp Type: 40W TT5, 4 Pin (FT40W/2611) P: Programmed Rapid Start Voltage: UNV 120 to 277 Volts HP-B: High Performance <10%; low profile can 000: Color — Black C: Packaging container style—Carton Pack Lamp Wattage* 120V, 277V 347V, UNV (120-277) Colors 000 – Black 001 – White CXXX X XXX XXX XXX # of Lamps No suffix=P P=Programmed Rapid Start I=Instant Start X T = Tray Pack SE – Side Exit C – Carton Pack BE – Bottom Exit I – Individual BES – Bottom Exit/Studs HP-B – Low Profile RH – Reduced Harmonics Example: C213UNVBES000C* Ballast Type: C Lamp Quantity: 2 Lamp Type: 13W Quad, 4 Pin (CFQ13W/G24q) Voltage: UNV 120 to 277 Volts BES: Bottom exit connection, studs 000C: Color — Black C: Packaging container style—Carton Pack UNDERSTANDING PART NUMBERS SPECIFICATIONS Magnetic 1. Ballast shall be Programmed Rapid Start. 2. Ballast shall incorporate lamp shutdown circuitry for end of lamp life protection. 3. Ballast shall allow for re-lamping without the need to cycle power. 4. Ballasts shall operate from 50/60 Hz input source of 120, 277, or 347 Volts with no damage to the ballasts. 4a. Ballasts shall operate from 50/60 Hz input source of 108-305 Volts with no damage to the ballasts for High Performance (HP) models. 5. Ballast shall be of metal can construction to meet all plenum requirements and to eliminate the need for extra grounding wires. 6. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 50 kHz to minimize interference with infrared control systems. 7. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. 8. Ballasts shall tolerate operation in ambient temperatures up to 140°F (55°C) without damage. 9. Ballasts shall have a maximum case temperature test point of 75°C printed on the label for easy fixture testing and troubleshooting. 10. Ballast shall have a maximum case temperature rise of 15°C. 11. Ballasts shall comply with FCC Part 18 NonConsumer Equipment for EMI (power line conducted) and RFI (Radiated). 12. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991. 13. Ballasts shall operate lamps with no visible flicker (< 3% flicker index). 14. Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage. 15. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. 16. Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp. 17. Ballasts shall have a Power Factor greater than .98 for the primary lamp. 18. The ballasts shall not have any PCBs. *Exception is C2642, which does not distinguish number of lamps. See catalog. For more information, visit www.gelighting.com 4-5 MAGNETIC COMPACT FLUORESCENT BALLASTS MAGNETIC COMPACT FLUORESCENT BALLASTS TWIN LAMPS–5 WATTS GE Product Code Mag Side Bottom Bottom or Exit Exit Exit Studs Elec Electrical Characteristics - 60 Hz ❍M 87634 — — Qty of Lamps Line Starting Catalog Input Current Current Number Watts Amps Amps Line Volt Min Ballast Start Power Factor Temp Factor Starting THD Method✿ Wir Dim Diag Nominal lamp watts and configuration TWIN, QUAD AND MULTIPLE LAMPS–13 WATTS Nominal lamp watts and configuration Lamp Type • 5 Watts GE Product Code Side Bottom Bottom Exit Exit Exit Studs Electrical Characteristics - 60 Hz 80673 80669 80671 80673 80669 80671 Lamp Type 13 Watts CFT5W/G23 • 7 Watts 1 277 4205F2P ■★ 11 0.08 0.19 1.00 0°F Normal <10% PH B2 CFT7W/G23 1 TWIN LAMPS–7 WATTS GE Product Code Mag Side Bottom Bottom or Exit Exit Exit Studs Elec Electrical Characteristics - 60 Hz ❍M 87634 — — Qty of Lamps 1 Line Starting Catalog Input Current Current Number Watts Amps Amps Line Volt 277 4205F2P ■★ 12 QUICK REFERENCE QUICK REFERENCE 0.08 0.19 Min Ballast Start Power Factor Temp Factor 0.95 Starting THD Method✿ 0°F Normal <10% Wir Dim Diag PH B2 Twin, 2-Pin Qty of Lamps E E 1 2 Line Volt Line Starting Catalog Input Current Current Number Watts Amps Amps 120 C213UNV◆ 18 120 C213UNV◆ 32 0.15 0.27 —— —— Min Ballast Start Power Factor Temp Factor 1.00 0.98 0°F 0°F High High Starting THD Method✿ Wir Dim Diag <10% <10% C10 C10 PRS PRS CFQ13W/G24q OR CFM13W/GX24q 18 19 OR Quad or Multiple, 4-Pin TWIN, QUAD AND MULTIPLE LAMPS–18 WATTS GE Product Code Side Bottom Bottom Exit Exit Exit Studs Electrical Characteristics - 60 Hz 80679 80675 80677 80679 80675 80677 1 Mag or Elec Mag or Elec Qty of Lamps Line Volt Line Starting Catalog Input Current Current Number Watts Amps Amps Min Ballast Start Power Factor Temp Factor Starting THD Method✿ Lamp Type • 13 Watts Wir Dim Diag CFT13W/2GX7 • 18 Watts E E 1 2 120 C218UNV◆ 120 C218UNV◆ 22 40 0.19 0.34 —— —— 1.00 0.98 0°F 0°F High High <10% <10% PRS PRS C10 C10 FT18W/2G11RS 18 19 TWIN & QUAD LAMPS–9 & 10 WATTS Qty of Lamps 1 Line Starting Catalog Input Current Current Number Watts Amps Amps Line Volt 277 4205F2P ■★ 14 0.11 0.18 Min Ballast Start Power Factor Temp Factor 0.95 0°F Starting THD Method✿ Normal <10% Lamp Type • 9 Watts Wir Dim Diag PH B2 CFT9W/G23 OR CFQ9W/G23 • 10 Watts 1 CFQ10W/G24d OR 13W: Twin T4, 4-Pin 18W: Twin T5, 4-Pin QUAD AND TRIPLE LAMPS–26 WATTS GE Product Code Side Bottom Bottom Exit Exit Exit Studs Electrical Characteristics - 60 Hz 87700 87700 87700 Mag or Elec Qty of Lamps Line Volt Line Starting Catalog Input Current Current Number Watts Amps Amps M 2 277 4226P▲ 62 0.22 0.34 Min Ballast Start Power Factor Temp Factor 0.90 32°F High Starting THD Method✿ Wir Dim Diag <20% C4 PH Lamp Type 18 Watts CFQ18W/G24q OR CFM18W/GX24q 8 Twin or Quad, 2-Pin OR Quad or Multiple, 4-Pin TWIN & QUAD LAMPS–13 WATTS - U.S. LAMPS GE Product Code Mag Side Bottom Bottom or Exit Exit Exit Studs Elec Electrical Characteristics - 60 Hz 87655 87655 87655 ❍ M Qty of Lamps 2 Line Starting Catalog Input Current Current Number Watts Amps Amps Line Volt 277 4214PBES▲ 26 0.09 0.09 Min Ballast Start Power Factor Temp Factor 0.85 32°F High Starting THD Method✿ Wir Dim Diag <20% C4 PH Lamp Type 13 Watts CFT13W/GX2 OR CFQ13W/GX23 9 TWIN LAMPS 5-13 WATTS OR Twin or Quad, 2-Pin U.S. type lamp Non-thermally protected models available. ✿ PH = Preheat F1 indicates an open core & coil unit with no mounting feet. F2 indicates an open core & coil unit with mounting feet. H2 indicates clamped & covered core & coil with mounting feet. F1R - Coil enclosed with plastic covers/no mounting feet. F2R - Coil enclosed with plastic covers/with mounting feet. ▲ Standard cases offer side lead configuration.Add “BE” suffix for Bottom Exit design or “BES” for Bottom Exit Studs design. ❍ Not approved for use in hazardous locations. ★ ■ { QUAD AND MULTIPLE LAMPS–26 WATTS GE Product Code Side Bottom Bottom Exit Exit Exit Studs Electrical Characteristics - 60 Hz 80689 80685 80687 80689 80685 80687 47509 47503 47506 Mag or Elec Qty of Lamps Line Volt Line Starting Catalog Input Current Current Number Watts Amps Amps Min Ballast Start Power Factor Temp Factor Starting THD Method✿ Lamp Type • 26 Watts Wir Dim Diag CFQ26W/G24d • 26 Watts E E E 1 2 2 120 C2642UNV◆ 28 120 C2642UNV◆ 56 120 C242UNV◆ 56 0.25 0.49 0.46 —— —— —— 1.02 0.98 1.02 0°F 0°F 0°F High High High <10% <10% <10% PRS PRS PRS C10 C10 C11 CFQ26W/G24q OR CFM26W/GX24q 18 19 19 OR ✿ PRS = Programmed Rapid Start; RS = Rapid Start F1 indicates an open core & coil unit with no mounting feet. F2 indicates an open core & coil unit with mounting feet. ◆ Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or “BES” for Bottom Exit connectors with 2˝ O.C. screw studs. ▲ Standard cases offer side lead configuration. Add “BE” suffix for Bottom Exit design or “BES” for Bottom Exit Studs design. Quad or Multiple, 4-Pin TWIN & QUAD LAMPS 13- 26 WATTS GE Product Code Mag Side Bottom Bottom or Exit Exit Exit Studs Elec Electrical Characteristics - 60 Hz ❍M 87634 — — All ballasts are UL listed, CSA approved and designated Class P (thermally protected). DIMENSIONS All ballasts are UL listed, CSA approved and designated Class P (thermally protected). REFERENCE DRAWING FOR C10 G C F A DIMENSIONS REFERENCE DRAWING FOR A1, A2, B1, B2 REFERENCE DRAWING FOR C3, C4, C5 C D C B B A B 1.64” C 1.97” D 2.38” E 2.81” Lead Lengths: 10˝ 4-6 A F 15/16" F 15/16" E A 1.94” D E E D C E D B A Dwg. B2 REFERENCE DRAWING FOR C11 B REFERENCE DRAWING FOR C3, C4, C5 Dwg. A B C D E F C4 2.34” 1.53” 5.20” 6.00” 6.59” 0.31” Lead Lengths: transforming the power of light ™ Side –12˝ BE/BES – 8˝ Dwg. A B C D E F C4 2.34” 1.53” 5.20” 6.00” 6.59” 0.31” Lead Lengths: Side • Black/Wh ite–11˝ • Red/Blu e–12˝ BE/BES – 8˝ Dwg. A C10 2.31” C11 2.98” B C D 1.00” 1.00” 4.25” 4.25” 4.61” 4.61” E F G 4.94” 0.98” 1.00” 4.94” 1.55” 1.00” Leadless-Poke-in wire connection For more information, visit www.gelighting.com 4-7 ELECTRONIC COMPACT FLUORESCENT BALLASTS ELECTRONIC COMPACT FLUORESCENT BALLASTS MULTIPLE LAMPS–32, 42, 57 & 70 WATTS GE Product Code Side Bottom Bottom Exit Exit Exit Studs Electrical Characteristics - 60 Hz 80689 80685 80687 80689 80685 80687 47509 47503 47506 47509 47503 47506 47509 47503 47506 47509 47503 47506 Mag or Elec Qty of Lamps Line Volt E E E E E E 1 1 1 2 1 1 120 120 120 120 120 120 Line Starting Catalog Input Current Current Number Watts Amps Amps C2642UNV◆ C2642UNV◆ C242UNV◆ C242UNV◆ C242UNV◆ C242UNV◆ 36 48 45 91 58 73 0.32 0.42 0.38 0.76 0.48 0.61 —— —— —— —— —— —— Min Ballast Start Power Factor Temp Factor 1.00 0.98 1.00 0.98 1.00 1.00 0°F 0°F 0°F 0°F 0°F 0°F High High High High High High QUICK REFERENCE QUICK REFERENCE Starting THD Method✿ Wir Dim Diag <10% <10% <10% <10% <10% <10% C10 C10 C11 C11 C11 C11 PRS PRS PRS PRS PRS PRS GE Product Code Side Bottom Bottom Exit Exit Exit Studs Electrical Characteristics - 60 Hz 80673 80669 80671 80673 80669 80671 Lamp Type • 32 WATTS CFM32W/GX24q 18 18 19 19 19 19 Nominal lamp watts and configuration 2D LAMPS–10 WATTS Nominal lamp watts and configuration Mag or Elec Qty of Lamps E E 1 2 Line Volt Line Starting Catalog Input Current Current Number Watts Amps Amps 120 C213UNV◆ 120 C213UNV◆ 15 26 0.12 0.22 Min Ballast Start Power Factor Temp Factor —— —— 1.02 1.02 0°F 0°F High High Starting THD Method✿ Wir Dim Diag <12% <12% C10 18a C10 19a PRS PRS Lamp Type 10 Watts CFS10W/GR10q Multiple, 4-Pin 2D, 4-Pin Lamp Type 42 Watts CFM42W/GX24q 2D LAMPS–16 WATTS GE Product Code Side Bottom Bottom Exit Exit Exit Studs Electrical Characteristics - 60 Hz 80673 80669 80671 80673 80669 80671 Multiple, 4-Pin Lamp Type 57 Watts CFM57W/GX24q Mag or Elec Qty of Lamps Line Volt Line Starting Catalog Input Current Current Number Watts Amps Amps Min Ballast Start Power Factor Temp Factor Starting THD Method✿ Lamp Type • 16 Watts Wir Dim Diag CFS16W/GR8 • 16 Watts E E 1 2 120 C213UNV◆ 120 C213UNV◆ 19 33 0.15 0.28 —— —— 0.95 0.95 0°F 0°F High High <10% <10% PRS PRS C10 18a C10 19a CFS16W/GR10q 2D, 2-Pin or 2D, 4-Pin Multiple, 4-Pin Lamp Type 70 Watts CFM70W/GX24q 2D LAMPS–21 WATTS GE Product Code Side Bottom Bottom Exit Exit Exit Studs Electrical Characteristics - 60 Hz 80679 80675 80677 80679 80675 80677 Multiple, 4-Pin Mag or Elec Qty of Lamps E E 1 2 Line Volt Line Starting Catalog Input Current Current Number Watts Amps Amps 120 C218UNV◆ 120 C218UNV◆ 24 43 0.18 0.37 —— —— Min Ballast Start Power Factor Temp Factor 0.98 0.95 0°F 0°F High High Starting THD Method✿ Wir Dim Diag <10% <10% C10 18a C10 19a PRS PRS Lamp Type 21 Watts CFS21W/GR10q ✿ RS = Rapid Start; PRS = Programmed Rapid Start ▲ Standard cases offer side lead configuration. Add “BE” suffix for Bottom Exit design or “BES” for Bottom Exit Studs design. ◆ Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or “BES” for Bottom Exit connectors with 2˝ O.C. screw studs. 2D LAMPS 10-21 WATTS MULTIPLE LAMPS 32-70 WATTS 2D, 4-Pin All ballasts are UL listed, CSA approved and designated Class P (thermally protected), Type HL. DIMENSIONS REFERENCE DRAWING FOR C10 ● Starter required: use COP-40 or FS-4 type fluorescent starter. ✿ RS = Rapid Start; PRS = Programmed Rapid Start ▲ Standard cases offer side lead configuration. Add “BE” suffix for Bottom Exit design or “BES” for Bottom Exit Studs design. ◆ Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or “BES” for Bottom Exit connectors with 2˝ O.C. screw studs. REFERENCE DRAWING FOR C11 G C F A All ballasts are UL listed, CSA approved and designated Class P (thermally protected), Type HL. B DIMENSIONS D E Dwg. A C10 2.31” C11 2.98” B C D 1.00” 1.00” 4.25” 4.25” 4.61” 4.61” E F G 4.94” 0.98” 1.00” 4.94” 1.55” 1.00” Leadless-Poke-in wire connection REFERENCE DRAWING FOR C10 G C F A B D E 4-8 transforming the power of light ™ Dwg. A C10 2.31” C11 2.98” B C D 1.00” 1.00” 4.25” 4.25” 4.61” 4.61” E F G 4.94” 0.98” 1.00” 4.94” 1.55” 1.00” Leadless-Poke-in wire connection For more information, visit www.gelighting.com 4-9 ELECTRONIC COMPACT FLUORESCENT BALLASTS MAGNETIC AND ELECTRONIC COMPACT FLUORESCENT BALLASTS QUICK REFERENCE 2D LAMPS–28 WATTS GE Product Code Side Bottom Bottom Exit Exit Exit Studs Electrical Characteristics - 60 Hz 87700 87700 87700 Mag or Elec Qty of Lamps Line Volt Line Starting Catalog Input Current Current Number Watts Amps Amps Min Ballast Start Power Factor Temp Factor Starting THD Method✿ Wir Dim Diag QUICK REFERENCE Nominal lamp watts and configuration T5 CIRCULAR LAMPS–22 & 40 WATTS Lamp Type • 28 Watts GE Product Code Mag Side Bottom Bottom or Exit Exit Exit Studs Elec Electrical Characteristics - 60 Hz CFS28W/GR8 • 28 Watts M 2 277 4226PBES▲ 66 0.23 0.34 0.93 25°F High <20% PH C4 7a 2D LAMPS–38 WATTS 80689 80685 80687 Mag or Elec Qty of Lamps M 2 E 1 Line Volt Line Starting Catalog Input Current Current Number Watts Amps Amps 120 4150P▲ 120 or C2642UNV◆ 277 or Min Ballast Start Power Factor Temp Factor Starting THD Method✿ Wir Dim Diag 84 0.72 — 0.80 0°F High <10% PRS C10 18a 33 0.13 — 0.80 0°F High <10% PRS C10 18a Line Volt 80689 80685 80687 E 1 47509 47503 47506 E 2 80689 80685 80687 E 1 47509 47503 47506 E 2 47509 47503 47506 E 2 Line Starting Catalog Input Current Current Number Watts Amps Amps 120 ◆ 277 C2642UNV 120 ◆ 277 C242UNV CFS28W/GR10q 2D, 2-Pin or 2D, 4-Pin GE Product Code Side Bottom Bottom Exit Exit Exit Studs Electrical Characteristics - 60 Hz 87623 — 87623 Qty of Lamps 120 ◆ 277 C2642UNV 120 ◆ 277 C242UNV 120 ◆ 277 C242UNV Lamp Type 38 Watts 25 50 42 80 79 66 64 0.22 0.10 0.42 0.19 0.37 0.16 0.65 0.29 0.54 0.24 Min Ballast Start Power Factor Temp Factor Nominal lamp watts and configuration Starting THD Method✿ Wir Dim Diag Lamp Type 22 Watts FC9T5-22W —— 1.00 0°F High <10% PRS C10 28 —— 1.05 0°F High <10% PRS C11 23 T5 CIRCULAR —— 0.98 0°F High <10% PRS C10 28 Lamp Type 40 Watts —— 0.98 0°F High <10% PRS C11 23 —— 0.98 0°F High <10% PRS C11 23 FC12T5-40W T5 CIRCULAR CFS38W/GR10q Lamp Type 22 & 40 Watts FC9T5-22W & FC12T5-40W 2D, 4-Pin ✿ RS = Rapid Start; PRS = Programmed Rapid Start ▲ Standard cases offer side lead configuration. Add “BE” suffix for Bottom Exit design or “BES” for Bottom Exit Studs design. ◆ Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or “BES” for Bottom Exit connectors with 2˝ O.C. screw studs. All ballasts are UL listed, CSA approved and designated Class P (thermally protected), Type HL. T5 CIRCULAR LAMPS 22-40 WATTS 2D LAMPS 28-38 WATTS T5 CIRCULAR ● Starter required: use COP-40 or FS-4 type fluorescent starter. ◆ Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or “BES” for Bottom Exit connectors with 2˝ O.C. screw studs. DIMENSIONS All ballasts are UL listed, CSA approved and designated Class P (thermally protected), Type HL. REFERENCE DRAWING FOR C10 REFERENCE DRAWING FOR C3, C4, C5 E D C B DIMENSIONS G C F A REFERENCE DRAWING FOR C10 B A 15/16" REFERENCE DRAWING FOR C11 F D E G C F A Dwg. A B C D E C3 C4 C5 C10 2.14” 2.34” 1.88” 2.31” 1.56” 1.53” 1.47” 1.00” 3.50” 5.20” 5.13” 4.25” 4.31” 6.00” 6.00” 4.61” 4.75” 6.59” 6.44” 4.94” Lead Lengths: F G 0.22” – 0.31” – 0.25” – 0.98” 1.00” Side –12˝ BE/BES – 8˝ Leadless-Poke-in wire connection 4-10 transforming the power of light ™ B D E Dwg. A C10 2.31” C11 2.98” B C D 1.00” 1.00” 4.25” 4.25” 4.61” 4.61” E F G 4.94” 0.98” 1.00” 4.94” 1.55” 1.00” Leadless-Poke-in wire connection For more information, visit www.gelighting.com 4-11 MAGNETIC AND ELECTRONIC COMPACT FLUORESCENT BALLASTS MAGNETIC AND ELECTRONIC COMPACT FLUORESCENT BALLASTS LONG TWIN T5 BALLASTS–24/27 WATTS (BIAX, DULUX L AND PLL) Qty of Lamps 47535 — — ❍E 1 47535 — — ❍E 2 80689 80685 80687 E 1 80689 80685 80687 E 2 47509 47503 47506 E 2 47535 — — ❍E 1 Line Starting Catalog Input Current Current Number Watts Amps Amps Line Volt 120 277 120 277 120 277 120 277 120 277 120 277 B224PUNV-C 27 52 B224PUNV-C 51 C2642UNV◆ 30 C2642UNV◆ 52 C242UNV◆ 51 50 B224PUNV-C 24 0.23 0.10 0.43 0,18 0.26 0.11 0.45 0.20 0.43 0.19 0.20 0.09 Min Ballast Start Power Factor Temp Factor Nominal lamp watts and configuration Starting THD Method✿ GE Product Code Side Bottom Bottom Exit Exit Exit Studs Electrical Characteristics - 60 Hz 87623 — — 80152 — — 80153 — — 80154 — — 80155 — — 80154 — — 80155 — — Lamp Type • 24/27 Watts Wir Dim Diag FT24W/2G11/RS • 24/27 Watts FT24W/2G10 —— 1.05 0°F High <10% <15% PRS -C 27 —— 1.00 0°F High <10% PRS -C 27 —— 0.90 0°F High <10% PRS C10 21 —— 0.85 0°F High <10% PRS C10 20 —— 1.02 0°F High <10% PRS C11 20 —— 1.05 0°F High <10% <15% PRS -C 27 • Long Twin T5, 4-Pin or • Long Twin T5, 4-Pin Qty of Lamps Line Volt Line Starting Catalog Input Current Current Number Watts Amps Amps Min Ballast Start Power Factor Temp Factor Starting THD Method✿ Lamp Type • 36/39 Watts Wir Dim Diag FT36W/2G11/RS • 36/39 Watts ❍E ❍E ❍E ❍E ❍E ❍E M 2 1 1 1 1 2 2 47535 — — ❍E 1 47540 — — ❍E 1 47540 — — ❍E 2 80156 89219 80157 — — — — — — ❍E ❍E ❍E 3 2 3 47509 47503 47506 E 2 47509 47503 47506 E 2 120 120 277 120 277 120 277 120 277 120 277 120 277 120 120 277 120 277 120 277 4150P▲ B140R120HP B140R277HP B240R120HP B240R277HP B240R120HP B240R277HP 88 38 38 46 46 75 75 B224PUNV-C• 36 B239PUNV-D• 38 B239PUNV-D• B340R120HP B240R120RH B340R277HP C242UNV•◆ C242UNV•◆ 71 70 106 69 106 68 67 68 67 0.76 0.32 0.13 0.40 0.17 0.62 0.27 0.30 0.13 0.32 0.15 0.59 0.26 0.89 0.58 0.39 0.57 0.25 0.57 0.25 —— —— —— —— —— —— —— 0.90 0.90 0.94 1.00 1.00 0.89 0.89 50°F 50°F 50°F 50°F 50°F 50°F 50°F High High High High High High High <20% <10% <10% <10% <10% <10% <10% RS RS RS RS RS RS RS C6 C6 C6 C6 C6 C6 C6 5 11 11 13✛ 13✛ 13 13 —— 0.95 0°F High <10% PRS -C 27 —— 1.02 0°F High <10% PRS -D 27 —— 0.97 0°F High <10% PRS -D 27 —— —— —— 0.90 0.90 0.90 50°F 50°F 50°F High High High <10% <20% <10% RS RS RS C6 C6 C6 15 13 15 —— 0.90 0°F High <10% PRS C11 20 —— 0.90 0°F High <10% PRS C11 20 FT36W/2G10 Long Twin T5, 4-Pin ✿ RS = Rapid Start; PRS = Programmed Rapid Start ▲ Standard cases offer side lead configuration. • New auto reset shutdown circuit ◆ Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or “BES” for Bottom Exit connectors with 2˝ O.C. screw studs. ❍ Not approved for use in hazardous locations. ✿ RS = Rapid Start; PRS = Programmed Rapid Start ▲ Standard cases offer side lead configuration. ◆ Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or “BES” for Bottom Exit connectors with 2˝ O.C. screw studs. ❍ Not approved for use in hazardous locations. T5 LONG TWIN 24-27 WATTS Mag or Elec Nominal lamp watts and configuration All ballasts are UL listed, CSA approved and designated Class P (thermally protected). DIMENSIONS REFERENCE DRAWING FOR C6 All ballasts are UL listed, CSA approved and designated Class P (thermally protected). E D DIMENSIONS C REFERENCE DRAWING FOR -D REFERENCE DRAWING FOR C10 Dwg. G C A B F A B D E Dwg. L W H M X -D 16.88” 1.16” 1.00” 16.28” --- A C6 2.40” Lead Lengths: Electronic Black/Wh ite-24˝ Red/Blue- 30˝ Yellow - 48˝ 111/16" 5/16" F B C D E F 1.55” 8.31” 8.89” 9.50” 1.19” Magnetic Models 4145P, 4245P, 4146P, 4246P Black/Wh ite-11˝ Red/Blue/Yellow -16˝ T5 LONG TWIN 36-39 WATTS GE Product Code Mag Side Bottom Bottom or Exit Exit Exit Studs Elec Electrical Characteristics - 60 Hz QUICK REFERENCE LONG TWIN T5 BALLASTS–36/39 WATTS (BIAX, DULUX L AND PLL) QUICK REFERENCE Magnetic (All other) Black/Wh ite- 20˝ Red/Blue/Yellow 30˝ REFERENCE DRAWING FOR C11 REFERENCE DRAWING FOR -C REFERENCE DRAWING FOR C11 REFERENCE DRAWING FOR -C Dwg. L W H M X -C 14.25” 1.18” 1.00” 13.75” --- Dwg. A C10 2.31” C11 2.98” B C D 1.00” 1.00” 4.25” 4.25” 4.61” 4.61” E F G 4.94” 0.98” 1.00” 4.94” 1.55” 1.00” Leadless-Poke-in wire connection 4-12 transforming the power of light ™ Dwg. L W H M X -C 14.25” 1.18” 1.00” 13.75” --- Dwg. A C11 2.98” B C D 1.00” 4.25” 4.61” E F G 4.94” 1.56” 1.00” Leadless-Poke-in wire connection For more information, visit www.gelighting.com 4-13 ELECTRONIC COMPACT FLUORESCENT BALLASTS MAGNETIC AND ELECTRONIC COMPACT FLUORESCENT BALLASTS LONG TWIN T5 BALLASTS– 40, 50, 55 & 96 WATTS (BIAX, DULUX L AND PLL) 80683 80690 80691 80680 80681 — — — — — — Mag or Elec Qty of Lamps M ❍E ❍E 2 1 1 1 E E E E 2 2 2 2 80683 — — E 2 80690 80691 80136 — — — — — — E E E 3 3 3 47542 — — ❍E 1 47542 — — ❍E 2 47542 — — ❍E 1 47542 80162 80163 — — — — ❍E — — Min Ballast Start Power Factor Temp Factor Starting THD Method✿ Wir Dim Diag <20% <20% <20% C6 C6 C6 Lamp Type 40 Watts Black 2 E E 2 2 120 4152P▲ 85 120 C240SI120RH▼ 40 277 C240SI277RH▼ 40 120 • 41 277C240PUNVHP-B 40 120 C340SI120RH▼ 75 277 C340SI277RH▼ 75 120 C240SI120RH▼ 69 277 C240SI277RH▼ 69 120 76 277 C240PUNVHP-B• 73 120 C340SI120RH▼ 98 277 C340SI277RH▼ 98 347 B332I347HP 97 120 277 B254PUNV-D• 60 120 111 277 B254PUNV-D• 108 120 277 B254PUNV-D• 58 120 106 277 B254PUNV-D• 104 120 B295SR120HP 172 277 B295SR277HP 172 0.68 0.40 0.17 0.34 0.15 0.68 0.28 0.61 0.27 0.63 0.27 0.88 0.39 0.28 0.50 0.23 0.93 0.40 0.49 0.22 0.89 0.38 1.44 0.63 —— —— —— —— 0.90 1.02 1.02 1.00 50°F 50°F 50°F 0°F High High High High RS IS IS <10% PRS FT40W/2G11 Blue BALLAST White Black Black —— —— —— —— 0.99 0.99 0.88 0.88 50°F 50°F 50°F 50°F High High High High <20% <20% <20% <20% IS IS IS IS C6 C6 C6 C6 14✛ 14✛ 12 12 —— 0.90 0°F High <10% PRS -B 20 —— —— —— 0.88 0.88 0.85 50°F 50°F 50°F High High High <20% <20% <10% IS IS IS C6 C6 C6 14 14 14 —— 1.29 0°F High <10% PRS -D 27 —— 1.18 0°F High <10% PRS -D 27 —— 0.90 0°F High <10% PRS -D 27 Lamp Type 50 Watts Blue BALLAST Blue Line Line Line FT50W/2G11 DIAGRAM 1 DIAGRAM 5 DIAGRAM 7A Long Twin T5, 4-Pin Lamp Type 55 Watts FT55W/2G11 —— —— —— 0.82 0.93 0.93 0°F -20°F -20°F High High High <10% <10% <10% PRS -D SER-RS SER-RS SL SL Yellow Yellow White Black Long Twin T5, 4-Pin 27 4 4 White Lamp Type 96 Watts Black BALLAST Red Red Blue Blue White BALLAST Blue Line BALLAST FT96W/GY10q Black Blue Blue Line Line DIAGRAM 8 T5 LONG TWIN 40-96 WATTS Blue Black Long Twin T5, 4-Pin 20 Red BALLAST Yellow 5 12✛ 12✛ -B Red White Yellow E — — — — Nominal lamp watts and configuration Line Starting Catalog Input Current Current Number Watts Amps Amps Line Volt WIRING DIAGRAMS DIAGRAM 8A DIAGRAM 9 Long Twin T5, 4-Pin ✿ RS = Rapid Start; IS = Instant Start; PRS = Programmed Rapid Start ▲ Standard cases offer side lead configuration. • New auto reset shutdown circuit ▼ Incorporates shutdown circuit ❍ Not approved for use in hazardous locations. All ballasts are UL listed, CSA approved and designated Class P (thermally protected). Line DIMENSIONS Black White BALLAST Blue Blue Red Red Line Black White Yellow Yellow BALLAST Blue Blue Red Red Line Black White Yellow Yellow BALLAST Red/White Red/White Blue Blue Red Red REFERENCE DRAWING FOR -SL REFERENCE DRAWING FOR -B DIAGRAM 11 REFERENCE DRAWING FOR C6 DIAGRAM 13 WIRING DIAGRAMS GE Product Code Side Bottom Bottom Exit Exit Exit Studs Electrical Characteristics - 60 Hz 87625 — — 80680 — — 80681 — — QUICK REFERENCE DIAGRAM 15 REFERENCE DRAWING FOR -D E D C A B 111/16" 5/16" F Dwg. A B C D E F C6 2.40” 1.55” 8.31” 8.89” 9.50” 1.19” Lead Lengths: Electronic Black/Wh ite-24˝ Red/Blue- 30˝ Yellow - 48˝ 4-14 Magnetic Black/Wh ite-20˝ Red/Blue/Yellow -30˝ Dwg. L W H M X -B -D -SL 9.50” 16.88” 11.75” 1.50” 1.18” 3.13” 1.00” 1.00” 1.78” 8.89” 16.20” 11.41” 0.88” --2.00” transforming the power of light ™ For more information, visit www.gelighting.com 4-15 MAGNETIC AND ELECTRONIC COMPACT FLUORESCENT BALLASTS WIRING DIAGRAMS Black Red Red White Green BALLAST Blue Blue Black Red Red White BALLAST Green DIAGRAM 18 Black White Blue Blue Green BALLAST DIAGRAM 18A DIAGRAM 19 Black Red White Red Black Yellow White Yellow Green BALLAST Green Red Red Yellow Yellow Blue Blue Blue Blue Red Red BALLAST Blue Blue Black White Green BALLAST Red Red Yellow Yellow Line Blue Blue Mount lamp within 1" of grounded metal reflector. WIRING DIAGRAMS DIAGRAM 19A DIAGRAM 20 DIAGRAM 21 Black Red White Green BALLAST Yellow Blue DIAGRAM 23 DIAGRAM 27 Black Red White Green BALLAST Blue DIAGRAM 28 4-16 transforming the power of light ™ HIGH INTENSITY DISCHARGE (HID) BALLASTS GE MEANS HIGHER EXPECTATIONS IN HIGH INTENSITY DISCHARGE. HIGH INTENSITY DISCHARGE BALLASTS GE offers a wide line of ballasts for all High Intensity Discharge (HID) lamp types (mercury, vapor, metal halide and high-pressure sodium) for applications ranging from 35-2000 watts, including core & coil, electronic, F-Can, potted core & coil, weatherproof, postline, and indoor encased ballasts. Our line includes the latest innovation in magnetic core & coil technology in years. GE offers a wide line of HID ballasts for applications ranging from 35-2000 watts. For more information, visit www.gelighting.com 5-1 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS PRODUCT OVERVIEW Core & Coil Core & coil ballasts are used in over 90% of all HID fixtures. GE‘s core & coil models are available for all HID lamp types, including single-, dual-, tri-, and multi-voltage designs. For added versatility and reduced inventory costs, GE has also introduced the industry's first Multi-5 ™ ballast (120, 208, 240, 277, or 480 Volt), featuring a 480-Volt tap on a conventional quad tap ballast. Our core & coil models are ideal for a wide variety of lighting applications, including factories, warehouses, gymnasiums and retail stores. All these ballasts feature precision-wound coils, ensuring even heat dissipation and the highest electrical integrity. GE‘s Precise™ is the next generation in core & coil technology, featuring a smaller, lightweight design and improved temperature performance. Precise™ fits virtually all applications, and has no exposed live metal parts. There are no plastic extrusions, which prevents breakage during shipping. Color-coded leads make installation easy. PRODUCT OVERVIEW HID Multi-5™ Ballasts Weatherproof GE's weatherproof ballasts are designed to stand up to the toughest outdoor conditions. They can be mounted remotely in the pole base or pole top. Since they're not hermetically sealed, they should not be mounted in areas prone to water accumulation. ensuring quiet operation. If necessary, these ballasts can be specified with an integral capacitor and starter. Ignitors GE offers the industry's most complete line of ignitors, including standard, automatic shutoff, instant restrike, and long distance ignitors. Indoor Encased Our HID indoor encased ballasts can be mounted remotely, which lets you use a smaller HID fixture while Multi-5™ Uni-Pak™ HID Capacitors F-Can Ballasts Core & Coil Ballasts F-Can These ballasts are used primarily for indoor downlighting applications where quiet operation is essential. All the components of these ballasts are enclosed in a fluorescent-style ballast can and are thermally protected. REMOTE MOUNTING DISTANCE Maximum Length in Feet for Remote Mounting of HID Ballasts to Lamp ANSI Lamp Type Watts 12 GA 14 GA 16 GA 18 GA H45 H46 H43 H38 H39 H37 H33 H35 H36 M57 M58 M59 M47 M48 Mercury Mercury Mercury Mercury Mercury Mercury Mercury Mercury Mercury Metal Halide Metal Halide Metal Halide Metal Halide Metal Halide 40 50 75 100 175 250 400 700 1000 175 250 400 1000 1500 534 498 620 620 272 194 132 297 208 272 194 132 196 146 336 313 390 390 171 122 83 187 131 171 122 83 123 92 211 197 245 245 107 77 52 117 82 107 77 52 77 58 132 123 154 154 67 48 33 74 51 67 48 33 48 36 PRODUCT OVERVIEW HID Ballast Kits PRODUCT OVERVIEW Potted Core & Coil Our potted core & coil ballasts are designed for applications requiring quieter or cooler operation than provided by standard coil & coil ballasts. The potting material is a sand-filled polyester which provides excellent sound-deadening and heat transfer qualities. For proper installation, ensure that remote ballasts are properly vented and mounted to a heat-dissipating surface. 5-2 transforming the power of light ™ For more information, visit www.gelighting.com 5-3 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS PRODUCT OVERVIEW APPLICATION AND OPERATING INFORMATION For maximum safety and reliability, all GE capacitors come with built-in bleed resistors. All GE capacitors are recognized by UL (UL file #E68320 for metal cases and #E182721 for plastic cases) and approved by CSA (CSA file #LR51331, metal cases only). Environmental safety is assured by use of biodegradable, nontoxic (no PCBs) dielectric fluid (soybean oil), patented for use in capacitors. Dry-film capacitors do not include protective devices. Since they can fail in a hazardous manner, it is the responsibility of the purchaser to take appropriate precautions. Capacitors GE has a comprehensive line of capacitors in metal cases (up to 520V ratings) and plastic cases (up to 400V ratings) – plus metal cases for dual-level operation. All GE capacitors are designed for 60,000 hours of continuous life. They're exceptionally reliable because we put them through accelerated life testing at 125% rated voltage and 110% of rated temperature +10°C. GE capacitors are normally packaged with ballasts. They Plastic Dry Type Capacitors may also be ordered separately, bulk packaged, or individually boxed with the suffix “BH” (metal cases only). Capacitor weights vary from 1/4 lb. to 1 lb. each. Dry Capacitors Type “P” plastic case capacitors described in this section are dry and do NOT contain safety interrupters (or oil). Plastic cases are UL rated “94V-O” (for use up to 100°C maximum). Type "P" capacitors are supplied with stranded copper wire leads 8 inches long (18 AWG, with 150°C rated insulation). Capacitor rolls are sealed inside plastic cases using epoxy. Design and testing of GE capacitors follow specifications in Electronic Industries Association (EIA) Standard 456-A, titled “Metalized Film Dielectric Capacitors for Alternating Current Application.” “P” capacitors are designed and rated for continuous duty AC voltages below 400VAC @ 50 or 60 Hz. Capacitors used with HID ballasts at voltages above 400VAC should contain interrupters (available from GE in oval “MF” and round “RMF” oil-filled metal cases). OIL–FILLED CAPACITORS GE Product Code uF VACr Part # Case Ht (") 89078 88982 89083 89071 89077 89007 12.0 15.0 24.0 24.0 24.0 48.0 400 400 360 400 480 330 005-2799-MF 005-1185-MF 005-3160-MF 005-2664-MF 005-2779-MF 005-1422-MF 1.50 oval 1.75 oval 1.75 oval 1.75 oval 1.75 oval 1.75 oval 2.7 2.7 3.1 3.1 3.9 3.9 Metal and Oil Filled Capacitors APPLICATION & OPERATING INFO. Protective Device (Only in metal cases) PRODUCT OVERVIEW Protective device to prevent case rupture Normal Cover Position 1/2" Barrier Barrier Normal Position of Protective Device 5-4 Position of Protective Device After Activation transforming the power of light ™ For more information, visit www.gelighting.com 5-5 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS BRACKET REFERENCE CHART APPLICATION AND OPERATING INFORMATION CORE & COIL ADJUSTABLE MOUNTING BRACKETS CORE & COIL WELDED BRACKETS All welded brackets are .093" thick. Routinely supplied with replacement kits. All welded brackets are .093" thick. Ref. Drawing B2 Ref. Drawing B1 .250 Slot 2 Places Ref. Drawing ADJ1 1.25" 1.00" 0.75"0.25" 4.60" 3.35" 5.25" 0.30" Underwriters Laboratories, Inc. Acceptance All F-Can and weatherproof ballasts listed in this catalog are Underwriters Laboratories, Inc. white card listed, except those for 347 Volt operation. All core & coil, potted core & coil and postline ballasts listed in this catalog are Underwriters Laboratories, Inc. yellow card listed (component recognized). Ballast Replacement Ballast replacement presents the possibility of exposure to potentially hazardous voltages and should be performed only by qualified personnel. All installation, inspection and maintenance should be performed only with the entire circuit power to fixture or equipment turned off. Installation shall be in accordance with National Electric Code. 4.00" Ref. Drawing B3 Ref. Drawing B1-A Heat A ballast, like any other electrical device, generates heat during normal operation. Planning for maximum heat dissipation with proper fixture design, installation planning and ballast selection will minimize the possibility of a heat-related problem arising. Excessive temperature will have an adverse effect on ballast life. Ref. Drawing ADJ2 .281 Slot 2 Places 1.25" 0.75"0.25" Ref. Drawing MB1 7.75" 5.50" 3.35" Normal Temperature Limits: • F-Can Ballasts Maximum case temperature: 90°C 0.09" 7.75" 0.43" 0.30" 1.75" 1.81" 4.00" 1.30" 45º 0.93" The resetting thermal protector functions as a thermostat which will open and temporarily deactivate the ballast when it exceeds the permissible temperature. The ballast will continue to cycle until the cause of overheating is eliminated. If the ballast is defective, it must be replaced. If the cause is external, the ballast will resume normal operation after abnormal conditions are eliminated. To attain normal ballast life, the maximum coil temperature of the ballast should not exceed the rating of the insulation system. A temperature increase of 10°C results in a 50% reduction of ballast life. Low Ambient Temperature (Cold) As temperatures drop, less and less vaporized gas is available within the arc tube of a high intensity discharge lamp, thereby causing an increase in the open circuit voltage required to initiate an arc in the lamp, until a point is reached where the lamp cannot be started. The minimum temperature at which any ballast listed in this catalog will provide reliable starting is listed with the electrical characteristics. Low ambient temperatures will also result in a slight increase in the warm-up period of any type of high intensity discharge lamp. Ballasts should be protected from weather, moisture, or other abnormal atmospheric conditions, unless specifically designed for use under adverse conditions. Ref. Drawing B1-B Ref. Drawing B4 • Weatherproof Ballasts Maximum case temperature: 90°C 0.93" 0.58" 2.75" .29" .281 Slot 6 Req. 1.75" 0.90" on center R. TYP. 0.50" TYP. 6.10" 1.00" 0.25" on center 0.50" 0.25" Dia. 2 Holes For use with: • 50 to 175 watt Mercury, High Pressure Sodium and Metal Halide and some 250 watt Metal Halide 6.75" on center 7.75" 4.60" Ref. Drawing MB2 7.25" 1.880" 5.25" .090" .460" BRACKET REFERENCE 1.300" 2.685" 1.750" 45° .835" .290" .930" .580" .290" .735" 1/4" Dia. 2 Holes For use with: • 250 to 1500 watt Metal Halide • 250 to 1000 watt High Pressure Sodium and Mercury Vapor 5-6 transforming the power of light ™ • Core & Coil Ballasts and Potted Core and Coil Ballasts Insulation: Class 180°C Maximum coil temperature: 165°C (measured by change of resistance method) All F-Can ballasts listed in this catalog are equipped with built-in automatic resetting internal thermal protection as a standard feature. Other ballast types may be available with thermal protection as an option. If required, consult your GE representative for availability and ordering information. Whenever a ballast with thermal protection is used, it is imperative that the fixture/ballast/lamp combination be heat tested under actual or simulated installation conditions to assure that the ballast will not cycle. Fusing The purpose of fusing an HID ballast is to remove the ballast from the power line in the event of a ballast system failure. A fuse does not protect the ballast from failing. Because the temperature in the ballast compartment is high, typically 90OC, fuse ratings are specified at 25OC, and that this rating declines as the temperature increases, HID fuse recommendations are made between 2 and 3 times the maximum current the ballast will draw during all normal conditions. Fast-blow fuses should not be used due to the possibility of high inrush currents. These currents are due to the fact that the power can be applied at any point in the AC voltage waveform. Standard and slow-blow are acceptable. When using the 120V tap for auxiliary lighting, a slow-blow fuse should be used to protect the ballast from damage from a fault in the auxiliary lighting circuit. For more information, visit www.gelighting.com APPLICATION & OPERATING INFO. 0.29" 5-7 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS Sound High intensity discharge lamp ballasts, like all electromagnetic devices, produce noise, or “hum.” It is the degree of noise which determines the existence of a problem. Ballast noise will only be noticeable when it exceeds the ambient sound level of the installation. It is obvious that a ballast designed primarily for outdoor or factory use would not be suitable in an office environment. The vast improvements in all high intensity discharge lamps and ballasts, and their excellent energy efficiency, have made them viable options for many indoor applications. The ballasts being considered should be carefully analyzed to ensure that there will not be an objectionable level of ballast noise. All F-Can ballasts listed in this catalog are “Sound Rated” to aid in the selection of a ballast that is proper for the environment in which it will operate. Potted core & coil ballasts are also designed to operate at reduced sound levels, generally several decibels lower than a standard core & coil ballast. Core & coil ballasts are not sound rated. In situations where light output necessitates using a ballast with a sound rating or noise level not normally acceptable, the ballast should be remotely mounted. Note, however, that not all ballasts listed in this catalog are designed or recommended for remote mounting. APPLICATION & OPERATING INFO. Polarity Polarity refers to the proper connection of ballast lead wires to line wires. To aid you in making a correct installation, GE ballast leads are color-coded for easy identification. The white or yellow ballast lead is to be connected to the neutral or common. Choose the appropriate ballast voltage lead to connect to the line. 5-8 Grounding Ballast and capacitors or starters in metallic casings must always be grounded. Ballasts and components may be grounded to the fixture or otherwise grounded. It would be hazardous to make contact with an ungrounded fixture, ballast or other electrical component while in operation. Operating Line Voltage Limits To receive the full benefits of rated lamp output and to prolong ballast life, it is essential that voltage supplied to an installation be maintained within the prescribed limits. In general, the line voltage supplied to a lag type ballast (reactor or high reactance autotransformer) should be maintained within 5% of the voltage for which the ballast is rated. The line voltage to lead type ballasts (constant wattage autotransformer or constant wattage isolated) should be maintained within 10%. Subjecting a ballast to excessive voltage for an extended period of time results in the deterioration of the coil insulation. This insulation breakdown will cause early ballast failure. Low voltage has no damaging effect on the ballast. It could, however, have an adverse effect on lamp performance and starting dependability. Maintenance Selecting and installing an adequate and efficient lighting system means nothing if it is not properly maintained. Maintenance must always be considered as part of the life cycle cost of any high intensity discharge lighting installation in order to assure the continued performance of the system as originally specified. First and foremost in importance is proper lamp maintenance. High intensity discharge lamps do not “burn out” like an incandescent bulb, but rather, undergo changes with the arc tube which prevent the lamp from starting properly, warming up and producing full light output. The beginning of difficulties such as these generally indicates the end of a lamp's useful life. Also, a dead lamp left in a fixture can be very damaging to the ignitor in systems which utilize them. To overcome this problem, GE offers automatic shutoff ignitors, which are described in the ignitor section of this catalog. In difficult locations, group replacement of all the lamps, working or not, is often more economical and convenient than spot replacement. The same, of course, applies to ballasts which might be approaching the end of their life. Only you can decide what is right for your lighting system, but what is important is that you have a maintenance program. transforming the power of light ™ APPLICATION AND OPERATING INFORMATION Periodic cleaning of the fixtures‘ lenses and reflectors is also important in maintaining proper light output. For indoor systems, maintenance of reflective surfaces, such as walls and ceilings, will also help assure proper levels of illumination. Standby Lighting and Packaging Standby Lighting To provide light during a high intensity discharge lamp's warm-up period, or the cool-down period following a power interruption which has extinguished it, incandescent standby lighting can be incorporated. This is accomplished by use of a standby lighting device, or remote, that switches off an incandescent lamp incorporated into the fixture once an arc has been established, or reestablished, in the HID lamp. Generally, standby lighting devices operate on 120 Volts, so a tap must be provided on ballasts designed to operate at higher line voltages. The 120 Volt terminal or lead on all GE dual-, tri- and multi-voltage ballasts can be used as a tap for standby lighting when the ballast is utilized for any of the higher voltages. Many single voltage ballasts are available with a 120 Volt tap and are listed throughout the core & coil data section. Other single voltage ballasts may be available in this version. Consult your GE representative for availability and price information. Any connection to the 120 Volt tap must be accomplished by means of a slow-blow fuse. This fuse will protect the ballast from abnormal conditions in the standby lamp circuit or its control device. The fuse should be located in the coolest place in the fixture (below 80°C). The recommended fuse amperage and maximum auxiliary lamp wattage are listed in this catalog for each ballast suitable for standby lighting applications. Be sure to follow the wiring instructions of the standby lighting device manufacturer. All applicable requirements of the National Electrical Code must be met. Packaging Standard Pack GE high intensity discharge lamp ballasts are routinely packed in easy-to-handle cartons containing from 1 to 20 units per carton, depending on the size and weight of the ballasts. Consult your GE representative regarding the number of “units per carton” for shipment with attached mounting brackets, capacitors (for high power factor units), and ignitors (if required). Other ordering criteria may cause packaging to vary. Individual Cartons All distributor replacement kits, weatherproof, postline, potted core & coil, and many larger ballasts are packaged in individual cartons. Individual cartons serve a threefold purpose: as a display carton, a stock package, and a shipping container for the retail market. Individual cartons may be packed in master cartons, depending on weight and size. Individual carton packaging may be available for other ballasts. Contact your GE representative regarding availability and cost. For more information, visit www.gelighting.com APPLICATION & OPERATING INFO. APPLICATION AND OPERATING INFORMATION 5-9 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS NOMENCLATURE TYPICAL SPECIFICATIONS FOR HID BALLASTS ABBREVIATIONS UL Bench Top Rise Temperature Code CWA Constant Wattage Autotransformer CWI Constant Wattage Isolated ISO Regulated Lag R-HPF Reactor—High Power Factor To facilitate UL inspection, the UL Bench Top Rise Temperature Code is shown on the core & coil ballast label as 1029X. 1029 is the UL Standard for HID Ballasts, and the X is the temperature code. If a fixture is UL listed for 1029D, then automatically all ballasts with an A, B, C or D temperature classification are acceptable for use within that same fixture. R-NPF Reactor—Normal Power Factor HX-HPF Lag Type — High Reactance Autotransformer—High Power Factor UL Bench Top Rise Letter Code Temperature Range for Class H (180°C) Ballasts HX-NPF Lag Type — High Reactance Autotransformer—Normal Power Factor A <75°C C 80°C<85°C E 90°C<95°C B 75°C<80°C D 85°C<90°C F 95°C<100°C Field 4 6 7 8 9 1 C 1 5 1 M 3 0 1 C Socket Type & Other Oddities (M/D/X/L) 3 Frame Size (E/3/4/5/X) 2 Style (C/F/W/E/I/P) 5 Number of Digits NOMENCLATURE Field 5-10 0 0 Ignitors 1. All ignitors will be epoxy-filled with either a plastic or aluminum external housing. 2. The ignitor shall be so designed to provide six months of lamp open circuit operation without failure. Kits 1. All HID kits shall be precision wound to ensure proper installation. 2. All HID kits shall be pre-wired. 3. All HID kits shall be built with color-coded leads. 4. All HID kits are to be UL and CSA recognized following the guidelines found in UL 1029 and CAN/CSA-22.2 No.74-92 (part 2 and 3). 5. GE Model______________ (or approved equal). Container Type (C/T/I/K) Wattage 1 A Pack Code (000 TO 999) Lamp Type (M/P/S/H) 3 M L T Circuit Type (R/A/I/O/L/M) 2 to 4 2 0 0 0 Primary Voltage (MLT/ML5/TRI/48T/ 120/277/ 230) 1 M Capacitors 1. All capacitors will be provided with a self-contained internal bleeder resistor. 2. All oil-filled capacitors will be housed in corrosion-resistant steel cans and contain .25" quick disconnect terminals. 3. All capacitors will be manufactured by ballast manufacturer. Description 1 (M) Metal Halide, (P) Pulse Start Metal Halide, (S) High Pressure Sodium, (H) Mercury 2 35 to 2000 Watts (Varies from two to four digits) 3 (MLT) Quad, (ML5) Multi-5, (TRI) TriVolt, (48T) 480/120, (120) 120, (277) 277, (230) 230V/50Hz 4 (R) Reactor, (A) CWA, (I) CWI, (O) IsoReg, (L) High Reactance/Lag, (M) MagLag 5 (C), C&C, (F) F-Can, (W) Weatherproof, (E) Encased/Potted C&C (I) Indoor Encased 6 (E) E&I, (3) 3x4, (4) 4-3/4, (5) 5-3/4, (X) Non Core and Coil 7 (M) Mogul or Medium, (D) Double Ended, (X) Multiple Lamps, (L) Low Loss 8 Pack Code (000 to 999, per pack code listing) 9 (C) Carton, (T) Tray, (I) Individual, (K) Kit transforming the power of light ™ SPECIFICATIONS 1 1. Ballasts shall be designed in accordance with all applicable ANSI specifications including ANSI C82.4 2. The Core & Coil ballast shall be designed with class "H" (180°C) or higher insulation system and vacuum impregnated with a 100% solids based resin. 3. All coils shall be precision wound. 4. Core & Coil ballasts shall be designed to operate at least 180 cycles of 12 hours on and 12 hours off, with the lamp circuit in an open or short-circuited condition and without undue reduction in ballast life. 5. Core & Coil ballast and starter combinations shall be designed to provide a reliable lamp starting down to -40°C for High Pressure Sodium and -30°C for Metal Halide at minimum rated line voltage. 6. Manufacturer shall provide written warranty against defects in workmanship, including replacement, for two years from date of manufacture. For more information, visit www.gelighting.com 5-11 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS DISTRIBUTOR REPLACEMENT KITS GE's HID distributor replacement kits contain the appropriate core & coil, a properly rated capacitor, and all other components required for ballast replacement. Our kits are the quickest and easiest to install of any on the market, thanks to unique design features like: • Prewired capacitor and ignitor (if required) to save time and reduce wiring errors • Color coded leads to reduce risk of incorrect wiring inside the fixture • Features that exceed UL standards, including capacitors that offer trip fault protection • Simple installation instructions and troubleshooting tips • UPS shippable box Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits Our kit offerings include many quad-voltage (120, 208, 240, or 277 volt) and 480 Volt core & coil ballasts, as well as the new Multi-5 five-voltage ballast. 480 Volt ballasts are equipped with a 120 Volt tap to accommodate standby lighting. GE‘s Multi-5™ Ballast Lamp Replacement kit is available for metal halide and high pressure sodium applications. This easy to carry, convenient, allin-one kit ensures ballast lamp compatibility. Distributor replacement kit cartons are packaged in master cartons in quantities from 1 to 6 units. Master carton quantities can be found on GE's list and distributor price sheets. Lamp Type HPS Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits 5-12 Pulse Start Metal Halide Wattage 150 175 175 250 250 250 250 250 400 400 400 400 1000 1000 1000 1500 1500 175 175 250 250 320 320 350 Voltage 480-120 Multi-5 120/208/240/277 Multi-5 120/208/240/277 Multi-5 Multi-5™ Uni-Pak™ Multi-5™ Uni-Pak™ Multi-5 120/208/240/277 480-120 Multi-5™ Uni-Pak™ Multi-5 120/208/240/277 480-120 120/208/240/277 480-120 120/208/240/277 480-120 120/208/240/277 480-120 120/208/240/277 480-120 120/208/240/277 Frame Size 3x4 3x4 3x4 3x4 3x4 4.25 x 4.75 3x4 4.25 x 4.75 4.25 x 4.75 4.25 x 4.75 4.25 x 4.75 4.25 x 4.75 4.25 x 5.75 4.25 x 5.75 4.25 x 5.75 4.25 x 5.75 4.25 x 5.75 3x4 3x4 4.25 x 4.75 4.25 x 4.75 4.25 x 4.75 4.25 x 4.75 4.25 x 4.75 GE Product Code 86711 87210 86741 87211 86765 87212 49763 49742 86808 86814 86803 49745 87213 86655 86650 86698 86693 86885 86876 86935 86926 86959 86952 86984 Part Number M15048TLC3M500K M175ML5AC3M500K M175MLTAC3M500K M250ML5AC3M500K M250MLTAC3M500K M250ML5AC4M500K M250ML5AC3M555K M250ML5AC4M555K M400ML5AC4M500K M400MLTAC4M500K M40048TAC4M500K M400ML5AC4M555K M1000ML5AC5M500K M1000MLTAC5M500K M100048TAC5M500K M1500MLTAC5M500K M150048TAC5M500K P175MLTAC3M500K P17548TAC3M500K P250MLTAC4M500K P25048TAC4M500K P320MLTAC4M500K P32048TAC4M500K P350MLTAC4M500K transforming the power of light ™ Mercury Voltage 120/208/240/277 480-120 480-120 120/208/240/277 120/208/240/277 480-120 120/208/240/277 480-120 120/208/240/277 480-120 Multi-5 120/208/240/277 Multi-5™ Uni-Pak™ Frame Size 4.25 x 4.75 4.25 x 4.75 4.25 x 5.75 3x4 3x4 3x4 3x4 3x4 3x4 3x4 4.25 x 4.75 4.25 x 4.75 4.25 x 4.75 GE Product Code 87008 86999 46936 87152 86587 86456 87074 87068 87094 87087 87214 87121 49757 Part Number P400MLTAC4M500K P40048TAC4M500K P75048TAC5M500K S50MLTLC3M500K S70MLTLC3M500K S7048TLC3M500K S100MLTLC3M500K S10048TLC3M500K S150MLTLC3M500K S15048TLC3M500K S250ML5AC4M500K S250MLTAC4M500K S250ML5AC4M555K 400 Multi-5 4.25 x 4.75 8725 S400ML5AC4M500K 400 120/208/240/277 4.25 x 4.75 87164 S400MLTAC4M500K 400 480-120 4.25 x 4.75 87198 S40048TAC4M500K 400 Multi-5 4.25 x 5.75 87217 S400ML5AC5M500K 400 120/208/240/277 4.25 x 5.75 87175 S400MLTAC5M500K 400 480-120 4.25 x 5.75 87206 S40048TAC5M500K 400 Multi-5™ Uni-Pak 4.25 x 4.75 49758 S400ML5AC4M555K 1000 Multi-5 4.25 x 5.75 87218 S1000ML5AC5M500K 1000 120/208/240/277 4.25 x 5.75 87056 S1000MLTAC5M500K 1000 480-120 4.25 x 5.75 87048 S100048TAC5M500K ™ 100 120/208/240/277 3x4 86519 H100MLTAC3M500K 175 120/208/240/277 3x4 86527 H175MLTAC3M500K 400 120/208/240/277 4.25 x 4.75 86542 H400MLTAC4M500K DISTRIBUTOR REPLACEMENT KITS DISTRIBUTOR REPLACEMENT KITS Lamp Type Metal Halide Wattage 400 400 750 50 70 70 100 100 150 150 250 250 250 For more information, visit www.gelighting.com 5-13 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS CORE & COIL ELECTRONIC BALLASTS METAL HALIDE LAMPS CORE & COIL ELECTRONIC BALLASTS METAL HALIDE LAMPS MH 35/39 WATTS MH 150 WATTS Nom Dimensions Capacitor Ignitor GE Max Open Total Max UL Product Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench Code Volts Number Type Input Current Voltage Rating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 35/39 WATT M130 METAL HALIDE LAMP 120 or 1.16 3 208 or 0.67 3 86824 M50MLTLC3M500K HX-HPF 67 4 PC1 1.0 2.6 6 280 1.2 2.2 1.31x2.16 2.2 4.3 MH100-3A 10 A 240 or 0.57 2 277 0.50 2 Nom Dimensions Capacitor Ignitor GE Max Open Total Max UL Product Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench Code Volts Number Type Input Current Vltg Rtg Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 150 WATT M102 METAL HALIDE LAMP - Medium Base 120 or 3.32 10 208 or 1.93 5 86718 M150MLTLC3M500K HX-HPF 185 245 4 PC1 2.3 3.9 16 300 1.6 2.7 1.56x2.69 2.7 7.3 MH100-3A 10 D 240 or 1.66 5 277 1.48 4 86711 480-120 M15048TLC3M500K HX-HPF 180 1.00 245 2 6 PC1 2.3 3.9 16 280 1.6 2.7 1.56x2.69 2.7 7.3 MH100-3A 10 F MH 70 WATTS Nom GE Max Open Product Input Catalog* Circuit Watts Input Circuit Fuse Wir Code Volts Number Type Input Current Voltage Rating Dia (1) 70 WATT M98 METAL HALIDE LAMP – Medium Base 120 or 1.70 4 208 or 1.04 3 86847 M70MLTLC3M500K HX-HPF 95 245 4 240 or 0.87 3 277 0.78 2 86839 480-120 M7048TLC3M HX-HPF 95 0.50 245 1 6 Dimensions Ref Dwg A B Capacitor Min Dry Film Mfd Volt Dia Ht MH 175 WATTS featuring Multi-5™ Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise PC1 1.3 2.9 8 280 1.2 2.7 1.31x2.16 2.2 4.3 MH100-3A 10 PC1 1.3 2.9 8 300 1.2 2.7 1.31x2.16 2.2 4.3 MH100-3A 10 A B B B E MH 100 WATTS Nom Dimensions Capacitor Ignitor UL GE Max Open Total Max Bench Product Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Top Code Volts Number Type Input Current Vltg Rtg Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Rise (1) 100 WATT M90 OR M92 METAL HALIDE LAMP - Medium Base 120 or 2.30 5 208 or 1.30 4 86675 M100MLTLC3M500K HX-HPF 130 250 4 PC1 1.7 3.2 10 280 1.2 2.7 1.31x2.16 2.2 6.3 MH100-3A 10 A 240 or 1.10 3 277 0.95 3 86667 480-120 M10048TLC3M500K HX-HPF 140 0.62 250 2 6 PC1 1.7 3.2 10 280 1.2 2.7 1.31x2.16 2.2 5.0 MH100-3A 10 C DIMENSIONS Nom GE Max Open Circuit Watts Input Circuit Fuse Product Input Catalog* Code Volts Number Type Input Current Voltage Rating (1) 175 WATT M57, M107 METAL HALIDE OR H39 MERCURY LAMPS 120 or 1.80 5 208 or 1.10 3 86741 M175MLTAC3M500K CWA 213 310 240 or 0.90 3 277 0.78 2 120 or 208 1.90 5 208 or 208 1.10 3 87210 240 or M175ML5AC3M500K CWA 208 0.95 300 3 277 or 208 0.85 2 480 210 0.50 1.5 Dimensions Wir Ref Dia Dwg A B Capacitor Min Dry Film Mfd Volt Dia Ht 21 PC1 2.2 3.6 10 400 1.6 2.7 1.56x2.69 2.7 6.8 n/a n/a A B A A 44 PC1 2.3 3.6 10 400 1.6 2.7 1.56x2.69 2.7 6.8 n/a n/a B DIMENSIONS REFERENCE DRAWING PC1 0.199 Dia Thru 4 Holes 0.199 Dia Thru 4 Holes A DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-6) For Capacitor Only (see pg. 5-6) For Distributor Replacement Kit (see pg. 5-12 thru 5-13) 000 200 500 500K W Bracket BRef. Dwg. L W M 1 4.00" 0.75" 3.35" PC1 5.25" 1.25" 4.60" B MAX S M L A DESCRIPTION 2.812˝ 0.250 Dia Thru 2 Holes S 0.25" 0.25" See pg. 5-6 for adjustable mounting brackets and detailed bracket drawings. 2.438˝ transforming the power of light ™ 3.500˝ 3.938˝ For Ballast Only For Bracket Only (see pg. 5-6) For Capacitor Only (see pg. 5-6) For Distributor Replacement Kit (see pg. 5-12 thru 5-13) SUFFIX * 000 200 500 500K W Bracket M L BRef. Dwg. L W M 1 4.00” 0.75” 3.35” PC1 5.25” 1.25” 4.60” B MAX S 2.812˝ 0.250 Dia Thru 2 Holes S 0.25” 0.25” See pg. 5-6 for adjustable mounting brackets and detailed bracket drawings. 2.438˝ MH 150-175 WATTS MH 35-100 WATTS REFERENCE DRAWING PC1 5-14 Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise 3.500˝ 3.938˝ For more information, visit www.gelighting.com 5-15 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS CORE & COIL ELECTRONIC BALLASTS METAL HALIDE LAMPS CORE & COIL ELECTRONIC BALLASTS METAL HALIDE LAMPS MH 400 WATTS featuring Multi-5™ MH 250 WATTS featuring Multi-5 ™ Nom GE Max Open Product Input Catalog* Circuit Watts Input Circuit Fuse Code Volts Number Type Input Current Voltage Rating (1) 250 WATT M58 METAL HALIDE OR H37 MERCURY LAMP - 4" Frame 120 or 2.60 8 208 or 1.58 5 86765 M250MLTAC3M500K CWA 294 280 240 or 1.30 4 277 1.12 3 120 or 2.60 8 208 or 1.60 5 87211 240 or M250ML5AC3M500K CWA 280 1.30 290 4 277 or 1.20 3 480 0.70 2 Dimensions Wir Ref Dia Dwg A B Capacitor Min Dry Film Mfd Volt Dia Ht Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise 21 PC1 3.0 4.3 15 400 1.6 3.6 1.91x2.91 2.7 9.0 n/a n/a 44 PC1 3.0 4.3 15 400 1.6 3.6 1.91x2.91 2.7 9.0 n/a n/a C D C C B B B C C Nom Dimensions Capacitor GE Max Open Product Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Code Volts Number Type Input Current VoltageRating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (1) 400 WATT M59 METAL HALIDE OR H33 MERCURY LAMP 86803 480-120 M40048TAC4M500K CWA 458 1.00 300 5 19 PC2 2.0 3.9 24 400 1.8 3.6 1.91x2.91 3.1 120 or 4.00 10 208 or 2.30 8 86814 M400MLTAC4M500K CWA 458 300 21 PC2 2.0 3.9 24 360 1.8 3.6 1.91x2.91 3.1 240 or 2.00 5 277 1.70 5 120 or 4.00 10 208 or 2.30 8 87212 240 or M400ML5AC4M500K CWA 458 2.00 300 5 44 PC2 2.0 3.9 24 400 1.8 3.6 1.91x2.91 3.1 277 or 1.70 5 480 1.00 5 Ignitor Total Max UL Wt Catalog Distance Bench (lbs.) Number to lamp (ft) Top Rise 11.2 n/a n/a 11.2 n/a n/a 11.2 n/a n/a E C D D E E D E D E MH 1000 WATTS featuring Multi-5™ MH 250 WATTS featuring Multi-5™ Nom Dimensions Capacitor Ignitor GE Max Open Total Max UL Product Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench Code Volts Number Type Input Current Voltage Rating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 250 WATT M58 METAL HALIDE OR H37 MERCURY LAMPS - 4.75" Frame 120 or 2.50 8 208 or 1.40 5 87212 240 or M250ML5AC4M500K CWA 293 1.30 305 4 44 PC2 1.8 3.6 15 400 1.6 3.6 1.91x2.91 2.7 10.8 n/a n/a A 277 or 1.10 3 480 0.65 2 0.199 Dia Thru 4 Holes 0.250 Dia Thru 4 Holes A A DIMENSIONS REFERENCE DRAWING PC2 B MAX MH 250 WATTS SUFFIX * 3.875˝ 3.500˝ 3.938˝ 4.375˝ 4.750˝ 4.60” S 0.25” 0.25” W Bracket 0.25” See pg. 5-6 for adjustable mounting brackets and detailed bracket drawings. 5-16 For Ballast Only For Bracket Only (see pg. 5-6) For Capacitor Only (see pg. 5-6) For Distributor Replacement Kit (see pg. 5-12 thru 5-13) 500K 1.25” n/a D n/a F B B B B 22.0 n/a B MAX B MAX DESCRIPTION 5.25” n/a 0.250 Dia Thru 8 Holes 0.250 Dia Thru 2 Holes 4.250˝ PC 2 22.0 A 0.250 Dia Thru 2 Holes BRef. Dwg. L W M 1 4.00” 0.75” 3.35” PC1 5.25” 1.25” 4.60” C 0.250 Dia Thru 2 Holes 0.250 Dia Thru 2 Holes 2.438˝ n/a REFERENCE DRAWING PC3 A 000 200 500 n/a 0.250 Dia Thru 4 Holes 4.250˝ 2.812˝ For Ballast Only For Bracket Only (see pg. 5-6) For Capacitor Only (see pg. 5-6) For Distributor Replacement Kit (see pg. 5-12 thru 5-13) 22.0 REFERENCE DRAWING PC2 REFERENCE DRAWING PC1 B MAX DESCRIPTION Ignitor Total Max UL Wt Catalog Distance Bench (lbs.) Number to lamp (ft) Top Rise MH 400-1000 WATTS DIMENSIONS Nom Dimensions Capacitor GE Max Open Product Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Code Volts Number Type Input Current Voltage Rating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (1) 1000 WATT M47 METAL HALIDE OR H36 MERCURY LAMP 86650 480-120 M100048TAC5M500K CWA 1080 2.30 420 10 19 PC3 2.8 4.6 24 480 n/a n/a 1.91x2.91 3.9 120 or 9.20 20 208 or 5.30 15 86655 M1000MLTAC5M500K CWA 1080 420 21 PC3 2.8 4.7 24 480 n/a n/a 1.91x2.91 3.9 240 or 4.60 10 277 4.00 10 120 or 9.00 20 208 or 5.20 15 87213 240 or M1000ML5AC5M500K CWA 1080 4.40 425 10 44 PC3 2.8 4.6 24 480 n/a n/a 1.91x2.91 3.9 277 or 3.90 10 480 2.30 10 transforming the power of light ™ M L S SUFFIX * 000 200 500 4.250˝ 3.875˝ 3.875˝ 4.375˝ 5.375˝ 5.750˝ 4.375˝ 4.750˝ 500K BRef. Dwg. L W M S PC 2 PC3 5.25” 7.75” 1.25” 2.75” 4.60” 6.10” 0.25” 0.25” See pg. 5-6 for adjustable mounting brackets and detailed bracket drawings. W Bracket S M L For more information, visit www.gelighting.com 5-17 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS CORE & COIL ELECTRONIC BALLASTS METAL HALIDE LAMPS CORE & COIL ELECTRONIC BALLASTS METAL HALIDE LAMPS MH 1500 WATTS PULSE START MH 175 WATTS GE Product Input Catalog* Circuit Code Volts Number Type (1) 1500 WATT M48 METAL HALIDE LAMP 86693 480-120 M150048TAC5M500K CWA 120 or 86698 208 or M1500MLTAC5M500K CWA 277 Nom Dimensions Max Open Watts Input Circuit Fuse Wir Ref Input Current Voltage Rating Dia Dwg A B Min Dry Film Mfd Volt Dia Ht 1610 PC3 4.3 6.4 32 525 n/a n/a 1.97x3.66 3.9 29.5 n/a n/a PC3 4.3 6.4 32 525 n/a n/a 1.97x3.66 3.9 30.0 n/a n/a 1610 3.50 14.00 8.00 7.00 450 450 10 19 40 25 21 20 Capacitor Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise E F E F GE Product Input Catalog* Circuit Watts Code Volts Number Type Input (1) 175 WATT M137 METAL HALIDE PULSE START LAMP 120 or 208 or 86885 P175MLTAC3M500K CWA 208 240 or 277 86876 480-120 P17548TAC3M500K CWA 210 Nom Dimensions Max Open Input Circuit Fuse Wir Ref Current Vltg Rtg Dia Dwg A B 1.80 1.10 0.90 0.78 0.45 255 255 5 3 3 2 2 Capacitor Min Dry Film Mfd Volt Dia Ht Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise 11 PC1 2.1 3.6 10 400 1.6 2.7 1.31x2.16 3.9 6.8 MH350-1 10 13 PC1 2.6 4.1 10 400 1.6 2.7 1.31x2.16 3.9 7.0 MH350-1 10 A B B B C PULSE START MH 250-320 WATTS Nom GE Max Open Product Input Catalog* Circuit Watts Input Circuit Fuse Code Volts Number Type Input Current Voltage Rating (1) 250/320 WATT M138 OR M132METAL HALIDE PULSE START LAMP 120 or 2.40 8 208 or 1.45 5 86935 P250MLTAC4M500K CWA 285 296 240 or 1.20 5 277 1.06 3 86926 480-120 P25048TAC4M500K CWA 285 0.62 290 2 120 or 4.10 8 208 or 2.50 7 86959 P320MLTAC4M500K CWA 365 292 240 or 2.00 5 277 1.85 5 120 or 3.25 8 86968 277 or P320TRIAC4M500K CWA 365 1.40 265 4 340 1.15 3 86952 480-120 P32048TAC4M500K CWA 405 1.06 292 3 DIMENSIONS DIMENSIONS Dimensions Wir Ref Dia Dwg A B 11 PC2 1.3 3.2 Capacitor Min Dry Film Mfd Volt Dia Ht Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise 14 400 1.6 3.6 1.91x2.91 2.7 9.3 MH350-1 10 A 13 PC2 2.0 3.8 14.0 400 1.6 3.6 1.91x2.91 2.7 11.3 MH350-1 10 A 11 PC2 2.0 3.8 20.5 400 1.8 3.6 1.91x2.91 3.1 11.2 MH350-1 10 A 15 PC2 1.7 3.7 24.5 300 1.6 3.6 1.91x2.91 2.7 11.0 MH350-1 10 A 13 PC2 2.0 3.8 20.5 400 1.8 3.6 1.91x2.91 3.1 11.3 MH350-1 10 A REFERENCE DRAWING PC2 REFERENCE DRAWING PC1 MH 1500 WATTS 0.250 Dia Thru 8 Holes 0.250 Dia Thru 4 Holes A B MAX A B MAX B MAX DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-6) For Capacitor Only (see pg. 5-6) For Distributor Replacement Kit (see pg. 5-12 thru 5-13) 000 200 500 500K Bracket W DESCRIPTION 0.250 Dia Thru 2 Holes M L BRef. Dwg. L W M S PC3 7.75” 2.75” 6.10” 0.25” 4.250˝ 2.812˝ 0.250 Dia Thru 2 Holes 0.250 Dia Thru 2 Holes S 4.250˝ 3.875˝ See pg. 5-6 for adjustable mounting brackets and detailed bracket drawings. 4.375˝ 5.375˝ 5.750˝ For Ballast Only For Bracket Only (see pg. 5-6) For Capacitor Only (see pg. 5-6) For Distributor Replacement Kit (see pg. 5-12 thru 5-13) SUFFIX * 000 200 500 2.438˝ transforming the power of light ™ 3.875˝ 3.500˝ 3.938˝ 4.375˝ 4.750˝ 500K BRef. Dwg. L W M PC1 5.25” 1.25” 4.60” PC 2 5-18 0.199 Dia Thru 4 Holes A PULSE START MH 175-320 WATTS REFERENCE DRAWING PC3 5.25” 1.25” 4.60” S 0.25” 0.25” W Bracket S M L For more information, visit www.gelighting.com 5-19 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS CORE & COIL ELECTRONIC BALLASTS METAL HALIDE LAMPS CORE & COIL ELECTRONIC BALLASTS METAL HALIDE LAMPS PULSE START MH 350-400 WATTS PULSE START MH 750 WATTS DIMENSIONS Nom Dimensions Open Circuit Fuse Wir Ref Vltg Rtng Dia Dwg A B 292 277 292 292 10 7 5 5 8 10 7 5 5 3 Capacitor Min Dry Film Mfd Volt Dia Ht Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise 11 PC2 2.0 3.8 1 1.5 3.2 22.5 280 — — — 1.6 3.6 1.56x2.69 RX1 22 400 1.8 3.6 1.91x2.91 3.1 11.2 MH350-1 10 A — 6.8 MH350-1 3.5 10 A 11 PC2 2.0 3.8 24 400 1.8 3.6 1.91x2.91 3.1 11.2 MH350-1 10 D 13 PC2 2.0 3.8 24 400 1.8 3.6 1.19x2.91 3.1 11.3 MH350-1 10 D Ignitor Total Max UL Wt Catalog Distance Bench (lbs.) Number to lamp (ft) Top Rise 22.0 HPS750-1B 10 D 22.0 HPS750-1B 10 E DIMENSIONS REFERENCE DRAWING RX1 REFERENCE DRAWING PC2 Nom Dimensions Capacitor GE Max Open Product Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (1) 750 WATT M149 METAL HALIDE PULSE START LAMP 120 or 6.90 15 208 or 4.00 8 46934 P750MLTAC5M500K CWA 810 400 11 PC3 2.8 4.6 24 480 n/a n/a 1.91x2.91 3.9 240 or 3.50 8 277 3.00 8 46936 480-120 P75048TAC5M500K CWA 810 2.00 400 6 13 PC3 2.8 4.6 24 480 n/a n/a 1.91x2.91 3.9 REFERENCE DRAWING PC3 0.250 Dia Thru 8 Holes 0.250 Dia Thru 4 Holes PULSE START MH 350-400 WATTS A 5-20 A B MAX B MAX PULSE START MH 750 WATTS GE Max Product Input Catalog* Circuit Watts Input Code Volts Number Type Input Current (1) 350 WATT M131 METAL HALIDE PULSE START LAMP 120 or 4.10 208 or 2.50 86984 P350MLTAC4M500K CWA 400 240 or 2.00 277 1.85 RX-NPF 3.80 42692 277 P350277RCEM500K 377 RX-HPF 2.34 (1) 400 WATT M135 METAL HALIDE PULSE START LAMP 120 or 4.10 208 or 2.50 87008 P400MLTAC4M500K CWA 458 240 or 2.00 277 1.85 86999 480-120 P40048TAC4M500K CWA 458 1.06 4.250˝ 0.250 Dia Thru 2 Holes DESCRIPTION DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-6) For Capacitor Only (see pg. 5-6) For Distributor Replacement Kit (see pg. 5-12 thru 5-13) 000 200 500 3.875˝ For Ballast Only For Bracket Only (see pg. 5-6) For Capacitor Only (see pg. 5-6) For Distributor Replacement Kit (see pg. 5-12 thru 5-13) 4.375˝ 4.750˝ SUFFIX * 000 200 500 0.250 Dia Thru 2 Holes Bracket W M L 500K 500K BRef. Dwg. L W M S PC 2 RX1 5.25” 4.00” 1.25” 0.75” 4.60” 3.35” 0.25” 0.25” W Bracket transforming the power of light ™ M L S S 4.250˝ BRef. Dwg. L W M S PC3 7.75” 2.75” 6.10” 0.25” 3.875˝ 4.375˝ 5.375˝ 5.750˝ See pg. 5-6 for adjustable mounting brackets and detailed bracket drawings. For more information, visit www.gelighting.com 5-21 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS CORE & COIL ELECTRONIC BALLASTS HIGH PRESSURE SODIUM LAMPS CORE & COIL ELECTRONIC BALLASTS HIGH PRESSURE SODIUM LAMPS HPS 50 WATTS HPS 100 WATTS Nom Dimensions Max Open Input Circuit Fuse Wir Ref Current Vltg Rtng Dia Dwg A B 1.24 0.59 0.50 0.44 120 5 3 3 2 4 PC1 Capacitor Min Dry Film Mfd Volt Dia Ht 1.4 2.6 5 Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise 280 1.2 2.2 1.31x2.16 2.2 4.1 HPS150-3A 10 A HPS 70 WATTS GE Product Input Catalog* Circuit Watts Code Volts Number Type Input (1) 100 WATT S54 HIGH PRESSURE SODIUM LAMP 87068 480-120 S10048TLC3M500K HX-HPF 135 120 or 208 or 87074 S100MLTLC3M500K HX-HPF 122 240 or 277 Nom Dimensions Max Open Input Circuit Fuse Wir Ref Current Vltg Rtng Dia Dwg A B 0.57 2.20 1.40 1.10 0.95 122 120 2 8 5 5 3 Capacitor Min Dry Film Mfd Volt Dia Ht 6 PC1 2.0 3.3 10 280 1.2 2.7 1.31x2.16 2.7 6.5 HPS150-3A 10 4 PC1 2.0 3.3 10 280 1.2 2.7 1.31x2.16 2.7 5.9 HPS150-3A 10 Capacitor Dry Film Dia Ht Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise — — — — 2.3 HPS150-3A 1.6 2.7 n/a n/a 2.5 Permanently Attached 1.2 2.2 1.31x2.16 2.2 6.0 HPS150-3A 3 A 10 1.2 2.2 1.31x2.16 2.2 10 A A B B B 4.1 HPS150-3A GE Max Product Input Catalog* Circuit Watts Input Code Volts Number Type Input Current (1) 150 WATT S55 HIGH PRESSURE SODIUM LAMP 1233-154U001 R-NPF 4.40 86606 120 1 171 1233-154W u R-HPF 3 2.40 87087 480-120 S15048TLC3M500K HX-HPF 189 0.72 120 or 3.00 208 or 1.65 87094 S150MLTLC3M500K HX-HPF 189 240 or 1.45 277 1.25 1 DIMENSIONS Nom Dimensions Open Circuit Fuse Wir Ref Vltg Rtng Dia Dwg A B 120 120 120 15 8 3 10 5 5 5 Capacitor Min Dry Film Mfd Volt Dia Ht 1 1 1A 1a 4A PC1 2.0 3.0 2.0 3.4 3.0 4.5 — — — — — — 52 240 1.8 3.6 2.12 2.9 14 280 1.6 2.7 1.56x2.69 2.7 3.2 HPS150-3 3.5 Permanently Attached 8.7 HPS150-3A 3 A 10 4 2.4 3.7 14 280 1.6 2.7 1.56x2.69 2.7 7.0 HPS150-3A 10 D C C B C PC1 .203" Dia Thru 4 Holes B MAX 0.594" A HPS 50 WATTS DESCRIPTION 2.625" 2.625" 2.188" REFERENCE DRAWING 1a 4.00” 0.75” 3.35” 0.25” See pg. 5-6 for adjustable mounting brackets and detailed bracket drawings. 5-22 M L A 1.750" 2.188" 000 200 500 2.438˝ 2.188" 3.500˝ 3.938˝ 2.625" 500K 2.625" B 2.188" REFERENCE DRAWING 1a 0.594" BRef. Dwg. L W M PC1 5.25” 1.25” 4.60” 1.750" 2.188" 1, 1a .203" Dia Thru 4 Holes transforming the power of light ™ 4.00” 0.75” 3.35” S 0.25” W Bracket 0.25” See pg. 5-6 for adjustable mounting brackets and detailed bracket drawings. M L B 0.438" 0.438" S A 0.594" 0.438" 0.438" 1, 1a SUFFIX * For Ballast Only For Bracket Only (see pg. 5-6) For Capacitor Only (see pg. 5-6) For Distributor Replacement Kit (see pg. 5-12 thru 5-13) 2.188" 3.500˝ 3.938˝ 500K Bracket 0.594" 2.812˝ 1.750" 2.188" W B A 0.250 Dia Thru 2 Holes SUFFIX * S 0.25” .203" Dia Thru 4 Holes B MAX 2.812˝ BRef. Dwg. L W M PC1 5.25” 1.25” 4.60” 0.438" 0.199 Dia Thru 4 Holes B A 0.250 Dia Thru 2 Holes 2.438˝ REFERENCE DRAWING 1 REFERENCE DRAWING PC1 0.438" 0.199 Dia Thru 4 Holes 000 200 500 Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise Also can be used on a 277 Volt line in conjunction with step-down transformers. DIMENSIONS REFERENCE DRAWING 1 REFERENCE DRAWING PC1 A For Ballast Only For Bracket Only (see pg. 5-6) For Capacitor Only (see pg. 5-6) For Distributor Replacement Kit (see pg. 5-12 thru 5-13) B B A A A HPS 150 WATTS Nom Dimensions GE Max Open Product Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt (1) 70 WATT S62 HIGH PRESSURE SODIUM lamp 1233-142U0001 R-NPF 83 2.10 8 1 1 1.3 2.6 — — 86605 120 120 1233-142W u R-HPF 1.30 5 1A 1a 1.3 2.7 28 120 86456 480-120 S7048TLC3M500K HX-HPF 94 0.34 120 2 6 PC1 1.4 2.8 7 280 120 or 1.40 5 208 or 0.83 3 86587 S70MLTLC3M500K HX-HPF 94 120 4 PC1 1.4 2.7 7 280 240 or 0.72 3 277 0.62 2 DESCRIPTION Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise HPS 100-150 WATTS GE Product Input Catalog* Circuit Watts Code Volts Number Type Input (1) 50 WATT S68 HIGH PRESSURE SODIUM LAMP 120 or 208 or 87152 S50MLTLC3M500K HX-HPF 64 240 or 277 S 1.750" 2.188" .203" Dia Thru 4 Holes For more information, visit www.gelighting.com 5-23 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS CORE & COIL ELECTRONIC BALLASTS HIGH PRESSURE SODIUM LAMPS CORE & COIL ELECTRONIC BALLASTS HIGH PRESSURE SODIUM LAMPS HPS 400 WATTS featuring Multi-5™ HPS 250 WATTS featuring Multi-5™ Nom Dimensions Capacitor GE Max Open Product Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Code Volts Number Type Input Current Voltage Rating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (1) 250 WATT S50 HIGH PRESSURE SODIUM LAMP 120 or 2.50 8 208 or 1.50 5 11 PC2 1.7 3.7 35 280 1.8 3.6 1.91x2.91 3.1 87121 S250MLTAC4M500K CWA 300 185 240 or 1.30 4 277 1.10 4 120 or 2.50 8 208 or 1.43 5 87214 240 or S250ML5AC4M500K CWA 300 1.25 200 4 46 PC2 2.0 3.8 35 280 1.8 3.6 1.91x2.91 3.1 277 or 1.10 4 480 0.65 4 Ignitor Total Max UL Wt Catalog Distance Bench (lbs.) Number to lamp (ft) Top Rise 10.3 HPS400-3A 10.3 HPS400-3 10 A 10 A GE Max Product Input Catalog* Circuit Watts Input Code Volts Number Type Input Current (1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP - 5 3/4" Frame 87206 480-120 S40048TAC5M500K CWA 465 1.00 120 or 3.90 208 or 2.25 87175 S400MLTAC5M500K CWA 467 240 or 1.95 277 1.70 120 or 3.90 208 or 2.25 87217 240 or S400ML5AC5M500K CWA 468 1.95 277 or 1.70 480 1.00 Nom Dimensions Open Circuit Fuse Wir Ref Vltg Rtng Dia Dwg A B 190 195 1.95 5 15 8 8 5 15 8 8 5 5 Capacitor Min Dry Film Mfd Volt Dia Ht Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise 13 PC3 2.3 4.2 48 280 1.8 4.6 1.91x2.91 3.9 15.5 HPS400-3A 10 D 11 PC3 2.3 4.1 48 280 1.8 4.6 1.91x2.91 3.9 15.5 HPS400-3A 10 D 46 PC3 2.5 4.3 48 280 1.8 4.6 1.91x2.91 3.9 15.5 HPS400-3 10 C HPS 400 WATTS featuring Multi-5™ HPS 1000 WATTS featuring Multi-5™ Nom GE Max Open Product Input Catalog* Circuit Watts Input Circuit Code Volts Number Type Input Current Voltage (1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP - 4 3/4” FRAME 87198 480-120 S40048TAC4M500K CWA 465 1.00 190 120 or 3.90 208 or 2.25 87164 S400MLTAC4M500K CWA 465 190 240 or 1.95 277 1.70 120 or 3.90 208 or 2.25 87215 240 or S400ML5AC4M500K CWA 465 1.95 190 277 or 1.70 480 1.00 Dimensions Fuse Wir Ref Rtng Dia Dwg 5 15 8 8 5 15 8 8 5 5 A 13 PC2 B 2.3 4.1 11 PC2 2.3 4.1 46 PC2 2.3 4.1 Capacitor Min Dry Film Mfd Volt Dia Ht Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise 55 240 1.8 3.6 1.91x2.91 3.5 14.5 HPS400-3A 55 240 1.8 3.6 1.91x2.91 3.5 14.5 HPS400-3A 55 240 1.8 3.6 1.91x2.91 3.5 15.5 HPS400-3 10 D D D C D B D C C B 10 10 GE Product Input Catalog* Circuit Watts Code Volts Number Type Input (1) 1000 WATT S52 HIGH PRESSURE SODIUM lamp 87048 480-120 S100048TAC5M500K CWA 1100 120 or 208 or 87056 S1000MLTAC5M500K CWA 1100 240 or 277 120 or 208 or 87218 240 or S1000ML5AC5M500K CWA 1.48 277 or 480 Nom Dimensions Max Open Input Circuit Fuse Wir Ref Current Vltg Rtng Dia Dwg A B 2.40 9.50 5.50 4.80 4.10 9.10 5.40 4.60 4.10 2.40 440 440 435 8 20 15 10 10 20 15 10 10 8 Capacitor Min Dry Film Mfd Volt Dia Ht Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise 13 PC3 3.8 6.0 26 525 n/a n/a 1.91x2.91 4.3 25.0 HPS1000-4B 15 D 11 PC3 3.8 5.6 26 525 n/a n/a 1.91x2.91 4.25 26.0 HPS1000-4B 15 C 46 PC3 3.8 5.5 26 525 n/a n/a 1.91x2.91 4.25 26.0 HPS1000-4 15 D DIMENSIONS DIMENSIONS REFERENCE DRAWING PC3 0.250 Dia Thru 4 Holes A DESCRIPTION For Ballast Only For Bracket Only (see pg. 5-6) For Capacitor Only (see pg. 5-6) For Distributor Replacement Kit (see pg. 5-12 thru 5-13) 000 200 500 Bracket W DESCRIPTION S 4.250˝ 0.250 Dia Thru 2 Holes M L 500K BRef. Dwg. L W M S PC 2 5.25” 1.25” 4.60” 0.25” 3.875˝ See pg. 5-6 for adjustable mounting brackets and detailed bracket drawings. 5-24 0.250 Dia Thru 8 Holes B MAX SUFFIX * transforming the power of light ™ 4.375˝ 4.750˝ For Ballast Only For Bracket Only (see pg. 5-6) For Capacitor Only (see pg. 5-6) For Distributor Replacement Kit (see pg. 5-12 thru 5-13) SUFFIX * 000 200 500 500K A Bracket W B MAX S M L 0.250 Dia Thru 2 Holes BRef. Dwg. L W M S PC3 7.75” 2.75” 6.10” 0.25” See pg. 5-6 for adjustable mounting brackets and detailed bracket drawings. 4.250˝ 3.875˝ HPS 400-1000 WATTS HPS 250-400 WATTS REFERENCE DRAWING PC2 4.375˝ 5.375˝ 5.750˝ For more information, visit www.gelighting.com 5-25 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS CORE & COIL ELECTRONIC BALLASTS MERCURY LAMPS F-CAN BALLASTS METAL HALIDE LAMPS MERCURY 100 WATTS MH 70-100 WATTS Nom Dimensions Capacitor Ignitor GE Max Open Total Max UL Product Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 100 WATT H38 or H44 MERCURY LAMP 120 or 1.05 3 208 or 0.60 2 86519 H100MLTAC3M500K CWA 125 250 21 PC1 1.3 2.5 10 280 1.4 2.7 1.31x2.16 2.7 4.0 n/a n/a A 240 or 0.52 2 277 0.45 2 MERCURY 175 WATTS GE Max Circuit Watts Input Product Input Catalog* Code Volts Number Type Input Current (1) 175 WATT H39 MERCURY LAMP 120 or 1.75 208 or 1.00 86527 H175MLTAC3M500K CWA 202 240 or 0.86 277 0.75 Nom Dimensions Open Circuit Fuse Wir Ref Vltg Rtng Dia Dwg A B 5 3 3 2 235 21 PC1 Capacitor Min Dry Film Mfd Volt Dia Ht Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise 1.6 2.9 17.5 300 1.6 3.6 1.56x2.69 3.1 5.2 n/a n/a Nom GE Max Open Product Input Catalog Circuit Input Input Circuit Fuse Code Volts Number Type Watts Current Vltg Rtng (1) 70 WATT M85 METAL HALIDE (with built-in ignitor) 86575 120 or 11210-277C-TC7 HX-HPF 98 2.00 250 6 277 0.90 3 (1) 70 WATT M98 METAL HALIDE (with built-in ignitor) 86578 120 or 11210-506C-TC22 HX-HPF 90 2.00 250 6 277 0.90 3 (1) 100 WATT M90 METAL HALIDE (with built-in ignitor) 86574 120 or 11210-239C-TC HX-HPF 125 2.20 250 8 277 1.00 4 7 22 Dimensions Wir Dia Max Dist Certifications Overall Case Mtg Total To Sound Length Length Dim Weight Lamp (ft) Rating UL CSA 34 11.75 10.55 11.10 11.0 20 B Yes Yes 34 11.75 10.55 11.10 11.0 20 B Yes Yes 34 11.75 10.55 11.10 11.0 20 B Yes Yes This ballast may also be used with (1) 70 watt S88 High Pressure Sodium lamp. M98 Designates Venture Lighting catalog numbers MH70/4/MED, C/4/MED or MS70/C/84/MED/W A MERCURY 400 WATTS Nom Dimensions Open Circuit Fuse Wir Ref Vltg Rtng Dia Dwg A B 245 10 8 5 5 Capacitor Min Dry Film Mfd Volt Dia Ht Ignitor Total Max UL Oil Filled Wt Catalog Distance Bench Oval Ht (lbs.) Number to lamp (ft) Top Rise F-CAN BALLASTS OPTIONAL ACCESSORIES 21 PC2 1.6 3.4 35 240 1.6 3.6 1.91x2.91 3.1 9.5 n/a n/a C Tee-Pee Lead Wire Covers Mounting Bracket Assemblies Catalog Number 2-BMB-1. DIMENSIONS REFERENCE DRAWING PC2 MERCURY 100-400 WATTS REFERENCE DRAWING PC1 0.199 Dia Thru 4 Holes 0.250 Dia Thru 4 Holes A A B MAX DESCRIPTION 1.000" 2.000" For use where ballast is attached to the surface of an enclosure or raceway. 0.406" 4.000" 4.500" 0.562" 1.437" 1.500" 2.562" 2.000" Mounting Bracket Assemblies 1.750" 0.218" Dia. B MAX Tee-Pee Lead Wire Covers SUFFIX * 2.812˝ For Ballast Only For Bracket Only (see pg. 5-6) For Capacitor Only (see pg. 5-6) For Distributor Replacement Kit (see pg. 5-12 thru 5-13) 000 200 500 500K 4.250˝ 0.250 Dia Thru 2 Holes 0.250 Dia Thru 2 Holes Splice Box Catalog Number SB-4. Ref. part #001-2009 2.438˝ 3.875˝ 3.500˝ 3.938˝ BRef. Dwg. L W M S PC1 PC 2 5.25” 5.25” 1.25” 1.25” 4.60” 4.60” 0.25” 0.25” See pg. 5-6 for adjustable mounting brackets and detailed bracket drawings. 5-26 Available for the remote installation of ballasts. Each assembly consists of two (2) mounting brackets, four (4) screws, four (4) washers and four (4) nuts. Catalog Number TP5. Ref. part #001-2013. 0.250" Dia. W For use with all F-Can Ballasts. Embossed Dimples 2 Places It is easily installed on the anchor bracket provided on each F-Can ballast. It contains five (5) 7/8" diameter knockouts. 4.375˝ 4.750˝ Bracket M L transforming the power of light ™ S 2.531" 2.000" 3.000" 2.812" 0.297" Dia. Mounting Holes 2 Places Splice Box REFERENCE DRAWING FOR F-CAN 0.850" Dia. Knockouts 5 Places Width Hole Ca se Le ng th Height MH 75-150 WATTS GE Max Product Input Catalog* Circuit Watts Input Code Volts Number Type Input Current (1) 400 WATT H33 MERCURY LAMP 120 or 3.90 208 or 2.22 86542 H400MLTAC4M500K CWA 440 240 or 1.92 277 1.68 g tin ngth un e Mo rall L e Ov Mounting Width For more information, visit www.gelighting.com 5-27 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS Nom GE Max Open Product Input Catalog Circuit Input Input Circuit Fuse Code Volts Number Type Watts Current Vltg Rtng (1) 175 WATT M57 METAL HALIDE OR H39 MERCURY LAMP 86563 120 or 1110-245SC-TC000I CWA 205 1.75 300 5 277 0.75 3 (1) 250 WATT M58 METAL HALIDE OR H37 MERCURY LAMP 86564 120 or 1110-246C-TC 8c CWA 295 2.50 280 8 277 1.10 4 (1) 400 WATT M59 METAL HALIDE OR H33 MERCURY LAMP 42670 120 or 1110-247SC-TC CWA 460 3.90 300 10 277 1.70 5 80728 120 or 1111-247SC-TC 23 CWA 460 3.90 300 10 277 1.70 5 Dimensions Wir Dia Max Dist Certifications Overall Case Mtg Total To Sound Length Length Dim Weight Lamp (ft) Rating UL CSA 34 14.30 13.15 13.75 14.0 * B Yes Yes 34 16.65 15.55 16.10 17.5 * C Yes Yes 34 19.25 18.05 18.60 23.0 * C Yes Yes 36 14.30 13.15 13.75 14.0 * B Yes Yes This ballast can be used with a MH200 ignitor to operate (1) 250 watt M103 lamp. Consult Universal for instructions. Two of these ballasts are required to operate the lamp. Electrical data is for two ballasts, except for “Sound Rating,” which is for each ballast. * Refer to Page 5-4. 8c 23 F-CAN BALLASTS METAL HALIDE LAMPS HPS 70 WATTS Nom GE Max Open Product Input Catalog Circuit Input Input Circuit Fuse Code Volts Number Type Watts Current Vltg Rtng (1) 70 WATT S62 HIGH PRESSURE SODIUM (with built-in starter) 120 or 1.60 5 86596 12210-237C-TC0001 HX-HPF 97 140 277 0.70 2 Dimensions Wir Dia 34 Max Dist Certifications Overall Case Mtg Total To Sound Length Length Dim Weight Lamp (ft) Rating UL CSA 11.75 10.55 11.10 9.2 10 B Yes Yes F-CAN BALLASTS OPTIONAL ACCESSORIES Tee-Pee Lead Wire Covers Mounting Bracket Assemblies MH/PSMH 175-400 WATTS & HPS 70 WATTS Catalog Number 2-BMB-1 (PC #86624) Available for the remote installation of ballasts. Each assembly consists of two (2) mounting brackets, four (4) screws, four (4) washers and four (4) nuts. Catalog Number TP5. Ref. part #001-2013. 0.250" Dia. 1.000" 2.000" For use where ballast is attached to the surface of an enclosure or raceway. 0.406" 4.000" 4.500" 0.562" 1.437" Mounting Bracket Assemblies 1.750" 0.218" Dia. Tee-Pee Lead Wire Covers Splice Box Catalog Number SB-4. Ref. part #001-2009 2.531" For use with all F-Can Ballasts. Embossed Dimples 2 Places It is easily installed on the anchor bracket provided on each F-Can ballast. It contains five (5) 7/8" diameter knockouts. 2.000" 3.000" 2.812" 0.297" Dia. Mounting Holes 2 Places Splice Box 5-28 1.500" 2.562" 2.000" REFERENCE DRAWING FOR F-CAN 0.850" Dia. Knockouts 5 Places Width Hole Ca se Le ng th Height SOLO™ DUAL-LEVEL HID SWITCHING CONTROLLER Application The SOLO™ dual level HID controller simplifies the complex. Providing single fixture control to ensure maximum ROI. The SOLO™ is capable of interfacing with metal halide, pulse start, and high-pressure sodium fixtures ranging from 175 watts to 1,650 watts. The SOLO™ reduces fixture power up to 50% in applications such as warehouse and manufacturing facilities. Key Features • For use with CWA (Constant Wattage AutoTransformer) ballasts only • Lamp Type Controlled: (Refer to ordering information when selecting control module) 175W to 1,650W Metal Halide 175W to 720W Pulse Start Halide 250W to 1,000W High Pressure Sodium • Initial Lamp Warm Up Time: 15 minutes • Warm Up Time If Lamp Goes Out: 15 minutes after lamp current is detected • Lamp Switching: Solid state switching and microprocessor watch dog provides reliable zero cross voltage switching from low to high and zero cross current switching from high to low. Inrush protected. • Continuous Dim Lamp Protection: The microprocessor monitors continuous dim time of the lamp. If lamp is dimmed continuously for 24 hours, lamp is automatically cycled to full power for 15 minutes to increase lamp life. • Capacitor: Series dim capacitor is mounted inside the SOLO™ module. Capacitor value is selected based on ballast manufacturing specifications. • Sensor Self-adjusting: Digital microprocessor constantly adjusts sensitivity for optimum performance. • Sensor Optics: 9.6 square inches of optical lens @ 2.15" focal length. (For long range sensing applications, the greater optical area and longer focal length increases performance.) • Sensor Range Pattern: (4) interchangeable lens options • Laser alignment: Allows accurate aiming of sensor pattern to within +/- 2 degrees • Sensor Timer Settings: 2-, 4-, 8-,16-, and 64-minute and 10-second test modes • Force Dim Option: After lamp warm up, sensor is disabled and lamp will dim continuously. Continuous dim protection is still active. • Self Diagnostics Test Button: Momentary push button initiates self-diagnostic to verify SOLO™ is functioning properly. • User Interface: 4 dip switches and self diagnostic push button • Mounting: 3/4" Threaded pipe mounting adapter with security screw. Mount such that sensor lens is even or below fixture reflector. • Power Cord: 6' power cord with Myzer plug. • Operating Temperature Range: (Indoor use only): -22ºF to +149ºF (-30ºC to +65ºC) • Weight: Less than 3 lbs. (without dim capacitor installed) • Dimensions: 13.25"H x 5.5"W x 2.6"D (33.6 x 14.0 x 6.6 cm) • Construction: Rugged, high impact, injectionmolded plastic. • UL and CUL listed • Warranty: Five-year limited HID CONTROLLERS F-CAN BALLASTS METAL HALIDE & PULSE START METAL HALIDE LAMPS MH AND PSMH 175-400 WATTS SOLO™ Installation Integrated HID Dual-level Switching Controller and Sensor g tin ngth un e Mo rall L e Ov Mounting Width transforming the power of light ™ For more information, visit www.gelighting.com 5-29 HIGH INTENSITY DISCHARGE (HID) BALLASTS HIGH INTENSITY DISCHARGE (HID) BALLASTS IGNITORS SOLO™ DUAL LEVEL HID SWITCHING CONTROLLER GE Product Code STANDARD IGNITORS Metal halide Catalog Number 86864 86864001I For 35 watt M130, 50 watt M110, 70 watt M98, 100 watt M90 or M92, or 150 watt M102 lamps. HIGH PRESSURE SODIUM 86635 86641 86635001I 86641001I For lamps of 150 watts or less except 150 watt S56. For lamps from 200 to 400 watts and 150 watt S56 with CWA ballasts. GE Product Code 41461 41462 41463 41461 TBD 41462 TBD 41463 TBD 41304 TBD 41324 TBD 41328 TBD 41479 41481 41277 41413 PART NUMBERS & ACCESSORIES 41502 41292 41500 41283 41290 5-30 41486 41429 41476 41402 41472 TBD 41390 Model LB-1 LB-2 LB-3 Models LB-1 LB-1-MS LB-2 LB-2-MS LB-3 LB-3-MS LB-1-EXTP1 LB-1-MS-EXTP2 LB-2-EXTP1 LB-2-MS-EXPT2 LB-3-EXPT1 LB-3-MS-EXTP2 Lens LB-Lens 15 LB-Lens 10 LB-Lens 07 LB-Lens 0806 Accessories LB-LAT-1 LB-CSR-10 LB-KIT-1 MP-C2P-10 MP-BP-10 Replacement Parts DC-6 LB-LAT-SW LB-COVER-1 LB-MOUNT-1 LB-CAP-WIRES MPNA-C2P-100 LB-FPP-10 Wattage Controlled Table 175W Metal Halide 175W, 200W Pulse Start Metal Halide 250W, 320W, 350W, 400W Metal Halide 250W, 320W, 350W, 400W, 450W Pulse Start Metal Halide 250 W High Pressure Sodium (HPS) 400 W High Pressure Sodium (HPS) (Maximum operating temperature @ 55°C) 1,500W, 1,650W Metal Halide (Maximum operating temperature @ 55°C) 1,000W Metal Halide (Maximum operating temperature @ 65°C) 740W, 1000W Pulse Start Metal Halide (Maximum operating temperature @ 55°C) 600W, 1,000W High Pressure Sodium (HPS) (Max. operating temperature @ 65°C) SoloTM SoloTM with MyzerSTART option SoloTM SoloTM with MyzerSTART option SoloTM SoloTM with MyzerSTART option SoloTM with 4 Pin Low Voltage Interface SoloTM with MyzerSTART option with 4 Pin Low Voltage Interface SoloTM with 4 Pin Low Voltage Interface SoloTM with MyzerSTART option with 4 Pin Low Voltage Interface SoloTM with 4 Pin Low Voltage Interface SoloTM with MyzerSTART option with 4 Pin Low Interface Lens 15, Aisle Lens, 1.5 x .23 Lens 10, Aisle Lens, 1.0 x .23 Lens 07, Aisle Lens, .70 x .16 Lens 0806, Area Lens, .80 x .60 Laser Alignment Tool Cable Strain Relief, 10 Pack Conversion Hardware Kit non-Myzer Port HID Fixtures MyzerPORT Bypass Shorting Plug, 10 pack MyzerPORT Bypass Shorting Plug, 10 pack Power Cable, 6 foot Laser Alignment Tool on/off Switch Capacitor and Wiring Compartment Cover 3/4" Threaded Mounting Adapter Two (2) Cap Connection Wires with Quick Disconnects MyzerPORT Connector Nipple adapter, 100 pack G2, 4 pin EXTP1-Port Plug, 10 pack * All orders require a completed HID capacitor sign-off sheet. Contact your GE representiative for more details. transforming the power of light ™ GE Product Lamp ANSI Code Watts Code Circuit Type Standard Ignitors Auto Shutoff Instant Restrike Long Distance Ignitors HIGH PRESSURE SODIUM IGNITORS GE Product Lamp Code Watts ANSI Code Circuit Type Standard Ignitors Auto Shutoff Long Distance Ignitors METAL HALIDE IGNITORS 86635 35 S76 Reactor HPS 150-3A HPS 150-45B HPS 150-5B HPS 150-4A 86864 35 M130 Reactor MH 100-3A — MH 100-5A 86635 50 S68 Reactor, HX HPS 150-3A HPS 150-45B HPS 150-5B HPS 150-4A 86864 50 M110 HX MH 100-3A — MH 100-5A 86635 70 S62 Reactor, HX HPS 150-3A HPS 150-45B HPS 150-5B HPS 150-4A 86864 70 M98 HX MH 100-3A MH 100-35B MH 100-5A 86635 100 S54 Reactor, HX HPS 150-3A HPS 150-45B HPS 150-5B HPS 150-4A 86864 100 M90 Reactor MH 100-3A MH 100-35B MH 100-5A 86635 150 S55 Reactor, HX HPS 150-3A HPS 150-45B HPS 150-5B HPS 150-4A 86864 100 M90 CWA MH 100-3A MH 100-35B MH 100-5A 86641 150 S56 CWA HPS 400-3A HPS 400-45B — HPS 400-4A 86864 150 M102 HX MH 100-3A MH 100-35B MH 100-5A 86641 250 S50 CWA HPS 400-3A HPS 400-45B — HPS 400-4A 86641 400 S51 CWA HPS 400-3A HPS 400-45B — HPS 400-4A Standard Ignitors Standard Ignitors are supplied with all High Pressure Sodium and Metal Halide ballasts requiring ignitors. These ballasts are supplied with an appropriate external ignitor unless the ignitor is permanently attached to or built into the ballast. Instant Restrike Ignitors An Instant Restrike Ignitor generates multiple pulses to restrike a lamp arc after a brief power interruption has extinguished it, without the typical 3-minute cool-down time. A Standard Ignitor cannot restrike an arc until the lamp has had time to sufficiently cool. Even though an Instant Restrike Ignitor can reinitiate the lamp arc immediately upon restoration of power, the lamp is still subject to warmup. The following chart is based on an S55 lamp. Time Lamp Is Extinguished Restrike Time 1 second 5 seconds 15 seconds 30 seconds 1 minute Cold Start 2 seconds Instant Instant Instant Instant Instant Light Output On Reignition 87% 83% 76% 62% 46% 36% Lamp Warmup Time 35 seconds 70 seconds 130 seconds 190 seconds 255 seconds 360 seconds Plug Replaceable Ignitors Incorporates terminals and a separate mounting base to simplify construction and replacement. Long Distance Ignitors Long Distance Ignitors are used in situations where an ignitor must be mounted further from the lamp than is recommended for a standard ignitor. The maximum lamp to ignitor distance for these ignitors is 50 feet, which may vary depending on the type of lamp, ballast, fixture, and wiring. Automatic Shutoff Ignitors In the event of a lamp failure, a Standard Ignitor will continue to pulse, trying to start the lamp. This may reduce the life of the ignitor. An Automatic Shutoff Ignitor will apply pulses for 10 to 12 minutes and then deactivate if a lamp arc cannot be initiated. Resetting the ignitor is accomplished by momentarily interrupting the power to the ballast. For this reason, these ignitors are not recommended for use on unswitched circuits. Shutoff Devices Ignitor Accessory (IA) devices can be used to convert a Standard Ignitor into an Automatic Shutoff Ignitor. Simply match the Shutoff Device catalog number on page 5-78 with the Standard Ignitor that is supplied with the ballast. Using the IA device with the Standard Ignitor eliminates the need to buy a separate Automatic Shutoff Ignitor. For more information, visit www.gelighting.com IGNITORS Part Numbers and Accessories Description 5-31 HIGH INTENSITY DISCHARGE (HID) BALLASTS WIRING DIAGRAMS REACTOR 277V Lamp Eyelet (Blue) 240V STARTER 3 Cap Lamp (Blue) 120V 1 STARTER Com Common Common (White) (White) Lamp Eyelet (Blue) 3 208V APACITOR** 2 (Black) Line (Black) Cap Line (Black) F 1 3 (Yellow) S STARTER 2 To Lamp Shell Com (Yellow) To Lamp Shell DIAGRAM 1 DIAGRAM 1A DIAGRAM 4 Line 277V (Black) Cap Cap Cap STARTER 3 n) ow (Br 120V 2 2 To Lamp Shell Com To Lamp Shell d) (Re STARTER Cap Cap (Red) (Red) 2 1 3 ) ow ell (Y STARTER Com Lamp Eyelet (Red) 1 3 208V 1 3 240V (Blue) 3 (Blue) 3 (Yellow) 120V Lamp Eyelet Lamp Eyelet (White) Cap 277V (Black) 347V Com (Yellow) (White) Com (Yellow) (Yellow) DIAGRAM 4A 347V DIAGRAM 6 Lamp Eyelet (Red) 347V 3 277V 1 Lamp Eyelet (Red) Cap (Red) 1 3 STARTER Cap Cap (Red) (Red) Line 3 277V 3 120V DIAGRAM 11 120V Cap Cap (Red) (Red) STARTER INC LAMP W MAX 2 2 Com Com Com Com (White) (White) (White) (White) DIAGRAM 13 120V (AUX) Com (Yellow) or (White) PERMISSIBLE Com (Yellow) or (White) DIAGRAM 15 DIAGRAM 19 B A L L A S T 277V 240V 277V or 347V Black 208V Cap (Red) BALLAST or 120V Black/Yellow Red Red White WIRING DIAGRAMS Red Black or Yellow White 120V 5-32 B A L L A S T Com Com (Yellow) (Yellow) 277V Black or 120V Black/Yellow Insulate Unused Input Lead for 300 Volts. DIAGRAM 21 DIAGRAM 34 DIAGRAM 44 DIAGRAM 46 Separately Insulate Unused Input Lead for 300 Volts transforming the power of light ™ DIAGRAM 36 AC (Alternating Current) - Current which passes from the generator in one direction and then the other, alternately. ANSI (American National Standards Institute) - Non-profit organization that generates voluntary product performance standards for many U.S. industries. ANSI Standards C82.1 applies to electromagnetic ballasts. Arc - Intense luminous discharge formed by the passage of electric current across a space between electrodes. Auto Rest Shutdown Circuit - Circuit senses lamp end life and will automatically shut off power to the lamp(s). When a new lamp is inserted in the socket, the ballast resets, and turns on the lamp automatically. Some shutdown circuits require the power to be interrupted before a new lamp will re-light. Ballast - Device for starting and regulating fluorescent and high intensity discharge lamps. Ballast Efficacy Factor (BEF) - Value used to evaluate various lighting systems based on light output and power input. The BEF can only be used to compare systems operating the same type and quantity of lamps. Ballast Factor (BF) - Measure of light output from lamp operated by commercial ballast as compared to a laboratory standard reference ballast. Ballast Factor .94 means ballast produces 94% of light produced by ANSI C82.2 reference ballast operating same lamps. Ballast Hum - Sound generated by the vibration of laminations in the electromagnetic field that transforms the current for discharge lamp use. Ballast Losses - Power which is supplied to a ballast but is not converted into lamp energy. Ballast loss is dissipated as heat. Bottom Exit (BE) - A configuration with leads or a wire-trap on the bottom or base of the ballast. This type of configuration is usually used when the ballast is mounted onto a junction box plate. Bottom Exit Studs (BES) - A configuration with screw studs mounted on the base plate or bottom of the ballast. The screws are 3/8" inches long with a #8-32 thread size (#8-32 nut). They are mounted on a twoinch center. The studs are usually used to mount the ballast directly onto a junction box plate. Canadian Energy Standards - Indicates ballast complies with Canadian Energy Standards and meets the requirements of CAN/CSA C654-M91. Canadian Standards Association (CSA) - Association that generates product performance and safety standards for many Canadian industries. Capacitor - Device in ballast that stores electrical energy. Often used for power factor correction and lamp regulation (see "Power Factor"). Cathode - See “Electrode”. Centigrade (C) - Celsius temperature scale where 0°C=32°F. Circle E - Designates a ballast meets or exceeds the requirements of Public Law 100-357 establishing standards of efficiency. Class P Thermal Protector - A switching device sensitive to current and heat that automatically disconnects ballast if the temperature exceeds UL temperature limitations. Coil - Windings of copper or aluminum wire surrounding the steel core in ballast. Core - Component of electromagnetic ballast that is surrounded by the coil. Core is comprised of steel laminations or solid ferrite material. Core & Coil Ballast - Another term for an electromagnetic ballast. Crest Factor (Lamp Current Crest Factor) - Ratio of peak lamp current to RMS or average lamp operating current. Efficacy - Lumen output per unit of power supplied to ballast (lumens per watt). Electrical Testing Laboratory (ETL) - Independent testing laboratory that performs ballast tests and certifies accuracy of performance data. Electrode - Metal filaments that emit electrons in a fluorescent lamp. Negatively charged free electrons emitted by one electrode are attracted to the positive electrode (anode), creating an electric current and arc between electrodes. Electromagnetic Ballast (Magnetic Ballast) - A ballast that uses a “Core & Coil” assembly to transform electrical current to start and operate fluorescent lamps. EMI (Electromagnetic Interference) - Electrical interference (noise) generated by electrical and electronic devices. Levels generated by high frequency electronic devices are subject to regulation by Federal Communications Commission (FCC). Filament - Metal Tungsten wire coated with Barium Oxide that emits electrons when voltage is applied. Filament Voltage - Voltage applied to the lamp cathode. Fluorescent Lamp - Gas filled lamp in which light is produced by the interaction of electrons with phosphors lining the lamp's glass tube. Foot Candles - Measure of light level on a surface being illuminated. Defined as one lumen of light per one square foot of surface area. Four-Pin Compact Fluorescent Lamps - Type of lamps that do not have any starter built into the base of the lamp. Therefore, the ballast has the starting circuit. Traditionally 4-pin lamps are designed to work with electronic ballasts; however, GE offers magnetic ballasts to operate some 4-pin lamps. Frequency - Rate of alternation in an AC current. Expressed in cycles per second or Hertz (Hz). Harmonic - An integral multiple of the fundamental frequency (60 Hz) that becomes a component of the current (see “Harmonic Distortion”). Harmonic Distortion - Distortion of an AC waveform caused by multiples of the fundamental frequency (harmonics). Odd triplet harmonics (thirds, ninths, etc.) may result in large currents on the neutral line in a four-wire Wye three-phase system. Hertz (Hz) - Unit used to measure frequency of alteration of current or voltage; cycles per second. High Efficiency (Energy Saving) Electromagnetic Ballast Ballast with core & coils, designed to minimize ballast losses compared to the “standard” ballast. High Intensity Discharge (HID) Lamp - A lamp containing a filled arc tube in which the active element becomes vaporized (a gaseous state) and is discharged into the arc stream to produce light. High Power Factor - A ballast whose power factor is corrected to 90% or greater by the use of a capacitor. Incandescent Lamp - Lamp in which light is produced by a filament heated by an electric current. Input Voltage - Power supply voltage required for proper operation of an arc discharge lighting ballast. Inputs Watts - The total power input to the ballast which includes lamp watts and ballast losses. The total power input to the fixture is the input watts to the ballast or ballasts and is the value to be used when calculating cost of energy and air conditioning loads. Instant Start Lamp - A fluorescent lamp with a single pin at each end. The lamp is ignited by a high voltage without any filament heating. For more information, visit www.gelighting.com GLOSSARY GLOSSARY 6-1 GLOSSARY GLOSSARY Instant Start - Lamp starting method in which lamps are started by high voltage input with no preheating of lamp filaments. Some rapid start lamps are designed so that they may be instant started. Laminations - Layers of steel, making up the "core" that is surrounded by the coils in a core & coil ballast. Lamp Current Crest Factor - See “Crest Factor”. Lamp Filament - See “Electrode”. Lamp Watts - Input power used to operate lamps. Lumens/Watt - A measurement of white light produced by each output watt. Metal Cases - Case design used in both magnetic and electronic ballasts. These ballasts are grounded once they are mounted to the fixture. They meet all safety codes, some of which do not allow plastic in open plenum areas. National Electric Code (NEC) - A nationally accepted electrical installation code to reduce the risk of fire, developed by the National Fire Protection Association. National Energy Standards for Fluorescent Ballasts - A federal law enacted in 1988 that sets energy standards for ballasts consistent throughout the United States. NOM - Laboratory that sets safety standards for building materials, electrical appliances and other products for Mexico. Non-PCB Capacitor - Capacitor used in ballasts to help provide power factor correction. Contains no polychlorinated biphenyls and meets EPA requirements. Normal Power Factor - Ballasts with power factor less than .90 and do not incorporate any means of Power Factor Correction. 6-2 Rapid Start - Lamp starting method in which lamp filaments are heated while open circuit voltage (OCV) is applied to facilitate lamp ignition. Series Lamp Operation - Refers to ballasts that employ a single current path passing through all lamps operated by the ballast. If one lamp should fail, companion lamps operated by the same ballasts will also extinguish or dim. Standard Alternating Current Frequency in the United States 60 Hertz (Hz) or 60 cycles per second. Total Harmonic Distortion (THD) - The combined effect of Harmonic Distortion on the AC waveform produced by a ballast or other device. Expressed as a percentage. Excessive levels of THD can create large currents on the neutral line of a four-wire Wye three phase system. (See “Harmonic Distortion”.) Transients - High voltage surges through an electrical system caused by lightning strikes to nearby transformers, overhead lines or the ground. May also be caused by switching of motors or compressors, as well as by short circuits or utility system switching. Can lead to premature ballast failure. Two-Pin Compact Fluorescent Lamps - Type of lamps that have the glow bottle starter built into the base of the lamp. Traditionally 2-pin lamps are designed to work with electromagnetic ballasts. UL Underwriters' Laboratories, Inc.- Laboratory that sets safety standards for building materials, electrical appliances and other products. Watts - Measurement of electrical ability to do work. Parallel Lamp Operation - Refers to ballasts that employ multiple output current paths from a single ballast to allow lamps to operate independent of one another, allowing other lamps operated by the ballast to remain lit should companion lamp(s) fail. PCB (Polychlorinated Biphenyls) - Chemical pollutant formerly used in ballast capacitors. Potting - Material used to completely surround and cover components of some magnetic and electronic ballasts. Potting compound fulfills functions of protecting components, dampening sound, and dissipating heat. Power Factor - Measurement of the relationship between the AC source voltage and current. High power factor ballasts require less AC operating current at the same wattage than an equivalent low power factor ballast. Formula: Power Factor equals Input Watts divided by the product of Line Volts times Line Amps (Volt Amps or VA). Power Factor Corrected - Ballasts that incorporate a means of Power Factor Correction but whose power factor is <90% and <50%. Preheat Lamp - A fluorescent lamp in which the filament must be heated by use of a starter before the arc is created. These lamps are typically operated with electromagnetic ballasts. Programmed Rapid Start - Lamp starting method which preheats the lamp filaments while not allowing the lamp to ignite and then applies the open circuit voltage (OCV) to start the lamp. The user may experience a half- to one-second delay after turning on the lamps while the pre-heating takes place. This type of starting circuit keeps lamp end blackening to a minimum and improves lamp life performance, especially in applications where the lamps are frequently switched on and off. Rapid Start Lamp - A fluorescent lamp with two pins at each end con nected to the filament. The filaments are heated by the ballast to aid in starting. Some rapid start lamps may be instant started without filament heat, for example, the F32T8 lamp. transforming the power of light ™ WARRANTY GE BALLAST WARRANTY General Electric Company, (hereinafter called “GE”) warrants to the purchaser that its lamp ballasts, (hereinafter called lighting products), will be free from defects in material and workmanship for the specified warranty periods beginning from the date of manufacture. Electronic Fluorescent Ballasts . . . . . . . . . . . . . . . . . . . . .Up to 60 Months Standard Electromagnetic, Fluorescent HID, SLH, Hybrid, Octek™ Fluorescent Ballasts . . . . . . . . . . . .24 Months Standard Fluorescent Sign Ballasts . . . . . . . . . . . . . . . . .24 Months MAX-3 or MSB-3 Series Fluorescent Sign Ballasts . . . . . .36 Months If it appears within the specified warranty period that any GE Lighting Product does not meet the warranty specified above, GE, at its option, will either repair or replace the Lighting Product at GE's expense. GE extends this limited warranty to the original or first end-user purchaser only. This warranty is conditional based upon proper storage, installation, use and maintenance. This warranty is not applicable to, and GE makes no warranty whatsoever with respect to, any Lighting Product not installed and operated in accordance with the National Electric Code (NEC), the Standards for Safety of Underwriters Laboratories, Inc. (UL), Standards for the American National Standards Institute (ANSI) or, in Canada, the Canadian Standards Association (CSA). Nor is this warranty applicable to any Lighting Product which has not been installed and operated in accordance with GE's specifications and connection diagrams or Lighting Products which have been subjected to abnormal operating conditions. This includes, but is not limited to, excessive temperatures as specified in GE's published literature. The conditions for any tests (to be) performed on Lighting Products which are claimed to have not performed in accordance with the terms of the warranty shall be mutually agreed upon in writing and GE may be represented at any such tests. No implied warranty of merchantability or fitness for a particular purpose shall apply beyond the aforementioned warranty period. The foregoing warranty is exclusive of all other statutory, written or oral warranties and no other warranties of any kind, statutory or otherwise are given or herein expressed. Warranty claims are to be made in accordance with GE's published Warranty Service Program which is available upon request. This warranty sets forth GE's obligations and responsibilities regarding its lighting products and is the exclusive remedy available to the claimant. Limitations of Liability, Under no circumstances, whether as a result of breach of contract, breach of warranty, tort, strict liability or otherwise, will GE be liable for consequential, incidental, special or exemplary damages, including, but not limited to, loss of profits, loss of use or damage to any property or equipment, cost of capital, cost of substitute product, facilities or services, down time costs or claims of claimants customers. GE's liability for all claims of any kind or for any loss or damages arising out of, resulting from or concerning any aspect of this warranty or from the Lighting Products or services furnished hereunder, shall not exceed the price of the specific Lighting Product which gives right to the claim, except in accordance with GE Technical Engineering Service Program. State Law Right, Some states do not allow the exclusion or limitation of consequential or incidental damages or the duration of time for an implied warranty. Therefore, the limitations or exclusions of consequential or incidental damage and implied warranties may not apply to certain claimants. This warranty provides the claimant with specific legal rights and claimants may have other rights that vary from state to state. Effective: 12/1/99 T R A N S F O R M I N G T H E P O W E R O F L I G H T FOR THE MOST UP-TO-DATE, PRODUCT INFORMATION, VISIT WWW.GELIGHTING.COM GE BALLAST PRODUCTS CATALOG © 2003 General Electric Company Printed in USA. 16122 (4/03) GE is a registered trademark of General Electric Company. All specification information is subject to change without notification.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Modify Date : 2004:05:07 13:37:38-05:00 Create Date : 2004:05:07 10:55:17-05:00 Title : GE - ballastBrochure11-08 Author : Creator : QuarkXPress(tm) 4.1 Producer : Acrobat Distiller 5.0.5 for Macintosh Page Count : 73 Mod Date : 2004:05:07 13:37:38-05:00 Creation Date : 2004:05:07 10:55:17-05:00 Metadata Date : 2004:05:07 13:37:38-05:00 Has XFA : NoEXIF Metadata provided by EXIF.tools