GE BallastBrochure11 08 648355 Catalog 1

529707-Catalog 529707-Catalog 529707-Catalog 768386 Batch5 unilog cesco-content

2014-07-05

: Pdf 648355-Catalog 1 648355-Catalog_1 768386 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 73

FEATURING:
ULTRA TM
ELECTRONIC
BALLASTS
TRANSFORMING
THE
POWER
OF
LIGHT
GE BALLAST
PRODUCTS
CATALOG
GE BALLAST PRODUCTS CATALOG
For more information, visit www.gelighting.com
GE BALLAST PRODUCTS CATALOG
ULTRA
ELECTRONIC BALLAST
MAX
FEATURING
Breakthrough technology that dramatically
improves efficiency, simplifies installation
and delivers optimal lamp performance.
TABLE OF CONTENTS
Fluorescent Electromagnetic Ballasts
Product Overview . . . . . . . . . . . . . . . . . . . . . .2-1
Application and Operation Information . . . . . . . .2-4
Typical Specifications . . . . . . . . . . . . . . . . . . .2-7
Lead Lengths . . . . . . . . . . . . . . . . . . . . . . . .2-8
F40T12 . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9
F40T10 . . . . . . . . . . . . . . . . . . . . . . . . . . .2-11
T12 High Output . . . . . . . . . . . . . . . . . . . . .2-12
T12 Very High Output . . . . . . . . . . . . . . . . . .2-14
F96PG17 . . . . . . . . . . . . . . . . . . . . . . . . . .2-15
F96T12 Very High Output . . . . . . . . . . . . . . .2-15
T12 Slimline . . . . . . . . . . . . . . . . . . . . . . . .2-16
Circline . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-18
Preheat and Trigger . . . . . . . . . . . . . . . . . . .2-19
Dimming . . . . . . . . . . . . . . . . . . . . . . . . . . .2-21
Export . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-22
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . .2-23
Sign Illuminating Ballasts
Product Overview . . . . . . . . . . . . . . . . . . . . . .3-1
Application and Operation Information . . . . . . . .3-2
High Output Sign Ballasts . . . . . . . . . . . . . . . .3-3
Lead Length & Ballast Footage . . . . . . . . . . . . .3-4
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . .3-5
Compact Fluorescent Ballasts
Product Overview . . . . . . . . . . . . . . . . . . . . . .4-1
Understanding Compact Fluorescent Technology .4-3
Specifications . . . . . . . . . . . . . . . . . . . . . . . .4-4
Understanding Part Numbers . . . . . . . . . . . . .4-5
Twin/Quad Lamps 5-13 Watts . . . . . . . . . . . . .4-6
Twin/Quad/Multiple Lamps 13-26 Watts . . . . . .4-7
Multiple Lamps 32-70 Watts . . . . . . . . . . . . .4-8
2D Lamps 10-38 Watts . . . . . . . . . . . . . . . . .4-9
T5 Circular Lamps 22-40 Watts . . . . . . . . . .4-11
T5 Long Twin Lamps 24-96 Watts . . . . . . . . .4-12
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . .4-15
High Intensity Discharge (HID) Ballasts
Product Overview . . . . . . . . . . . . . . . . . . . . . .5-1
Application and Operation Information . . . . . . . .5-5
Nomenclature . . . . . . . . . . . . . . . . . . . . . . .5-10
Specifications . . . . . . . . . . . . . . . . . . . . . . .5-11
Distributor Replacement Kits . . . . . . . . . . . . .5-12
Core and Coil . . . . . . . . . . . . . . . . . . . . . . .5-14
Metal Halide . . . . . . . . . . . . . . . . . . . . . .5-14
Pulse Start Metal Halide . . . . . . . . . . . . .5-19
High Pressure Sodium . . . . . . . . . . . . . . .5-22
Mercury . . . . . . . . . . . . . . . . . . . . . . . . .5-26
F-Can Ballasts . . . . . . . . . . . . . . . . . . . . . . .5-27
HID Controls/Part Numbers & Accessories . . .5-29
Ignitors . . . . . . . . . . . . . . . . . . . . . . . . . . .5-31
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . .5-32
Glossary
Warranty
Electronic Ballasts Featuring
New UltraMaxTechnology
Product Overview . . . . . . . . . . . . . . . . . . . . . .1-1
UltraMax
TM
Electronic Ballasts Overview . . . . . . .1-2
UltraMax
TM
System Performance Matrix . . . . . .1-7
UltraMax
TM
Ordering Guide and System Wattage 1-8
Additional Electronic Ballast Overview . . . . . . . .1-9
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-11
Performance . . . . . . . . . . . . . . . . . . . . . . . .1-12
Specifications . . . . . . . . . . . . . . . . . . . . . . .1-14
Ballast Matrix . . . . . . . . . . . . . . . . . . . . . . .1-18
F17T8 . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-20
F25T8 . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-21
F28T8 . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-22
F32T8 . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-23
F40T8 . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-28
F96T8 Slimline . . . . . . . . . . . . . . . . . . . . . .1-29
T8HO . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-30
T5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-31
T10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-32
T12 Rapid Start . . . . . . . . . . . . . . . . . . . . . .1-33
T12 Slimline . . . . . . . . . . . . . . . . . . . . . . . .1-36
T12HO High Output . . . . . . . . . . . . . . . . . . .1-37
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . .1-38
Dimming Product Overview . . . . . . . . . . . . . .1-40
Dimming Application and Operating Information 1-41
Dimming Specifications . . . . . . . . . . . . . . . . .1-42
Dimming Controls Cross Reference . . . . . . . .1-43
Dimming T8 . . . . . . . . . . . . . . . . . . . . . . . .1-44
Dimming Wiring Diagrams . . . . . . . . . . . . . .1-46
ELECTRONIC
FLUORESCENT BALLASTS
GE offers electronic ballasts for a wide range of applications.
A COMPREHENSIVE RANGE
OF SOLUTIONS ...
FROM THE NAME YOU TRUST
GE introduced the first
fluorescent ballast more than
60 years ago. Today we are
providing high frequency
electronic ballasts for almost
every fluorescent application.
With our UltraMaxTM Ballasts, we are bringing you the future in
ballast performance.
GE revolutionizes lighting again with new, breakthrough technology.
Our patented UltraMaxelectronic ballasts transform the power of
light into efficiency and savings from store shelves to the installation
site. It all starts with UltraMax's Multi-Voltage Control (MVC), which
automatically adjusts to handle voltage from 120V through 277V.
That cuts the ballast models you need to stock from 40 down to 13,
which can dramatically reduce inventory carrying costs. UltraMax
ballasts have ArcGuard Protection, too, with a UL Type CC Anti-Arc
Rating. Plus, they’re ultra lamp friendly, with an industry low Lamp
Current Crest Factor of 1.4 for optimal lamp performance. And the
small, low-profile design of the UltraMaxballasts makes retrofits
effortless at the job site.
For more information, visit www.gelighting.com
1-1
PRODUCT
OVERVIEW
The choice for High light
output.
With a ballast factor of 1.15,
UltraMaxTM H delivers the most
lumens for maximum light
or when you want more
savings using fewer lamps.
This is the first high-
efficiency high-light
output line for 2, 3
and 4 T8 lamps.
The Normal light option balances efficiency
and illumination. The most-used type
of ballast, the N line saves energy without
sacrificing lumens. A ballast factor of .87
meets most application needs. For 1, 2, 3,
and 4 T8 lamps in 2', 3', 4', and 8'
lengths.
The Low watt option for Max energy savings.
With a ballast factor of .77, the
L line is the most energy efficient choice.
It provides adequate illumination for most
applications. For 1, 2, 3, and 4 T8 lamps in 2’,
3’, and 4’ lengths.
ULTRA
ELECTRONIC BALLAST
MAX
ULTRA
ELECTRONIC BALLAST
MAX
ULTRAMAXTM
ELECTRONIC
BALLASTS
ULTRAMAXTM
ELECTRONIC
BALLASTS
transforming the power of light
1-2
GE revolutionizes lighting again with
new, breakthrough technology.
In the GE labs, our engineers have developed
a new breed of ballasts to make lighting systems
that save more energy, are more adaptable, and
deliver optimal lamp performance. The innovative,
patented technology in our new UltraMaxTM elec-
tronic ballasts exceeds expectations, and is like
nothing else available.
Multi-Voltage technology means a single
UltraMaxTM model handles voltage from
120 through 277.
UltraMaxTM Ballasts can virtually “read’’ the
incoming voltage and adapt automatically to any
voltage from 108V to 305V. The benefits of Multi-
Voltage Control (MVC) are obvious:
• Fewer models handle more jobs, eliminating
inventory hassles.
• MVC simplifies installation and eliminates
guesswork at the job site.
• MVC compensates for incoming voltage
fluctuations or variations from unreliable
power.
UltraMaxTM is the only full line of
T8 ballasts with a UL Type CC Anti-Arc
Rating.
UL Type CC Rating is a stringent designation
of protection against arcing in electrical devices.
GE’s Arc-Guard design eliminates the damaging
effects arcing can have on lamps, ballasts and
sockets.
High efficiency delivers up to 40%
energy savings.
Ballasts are the new frontier of energy efficien-
cy. Systems combining UltraMaxTM electronic bal-
lasts and T8/WM lamps can deliver up to 40%
energy savings over standard electromagnetically
ballasted T12 systems. Since energy costs are typi-
cally 80% of the overall cost of light, a more effi-
cient system can pay for itself in a very short time
and provide an excellent return on investment.
UltraMaxTM is ultra lamp friendly.
With an industry low lamp current crest factor
(LCCF) of 1.4, UltraMaxTM ensures optimal lamp
operation and maximum lamp life, which can save
on lamp and maintenance costs.
Active Current Regulation (ACR)
technology is a patented advantage.
UltraMax’s patented ACR modular design
means individual inverter modules regulate the
output current to each lamp. So, unlike conven-
tional ballasts, if one lamp fails, the remaining
lamps are not forced to operate at a higher cur-
rent. This ensures optimal lamp performance.
Anti-Striation Control for better light
quality, with no striations.
UltraMaxTM is the only line of T8 ballasts with
Anti-Striation Control. This advanced technology
eliminates the maintenance issues caused by stri-
ating lamps, often referred to as spiraling or
swirling. This provides a flicker- and worry-free
environment.
Fully parallel independent lamp
operation makes system easier to
maintain.
If one lamp fails, all the others in the system
stay lit. That means system maintenance is easier
to manage.
UltraMaxTM is ultra-cool.
UltraMax’s high efficiency design results in
ultra-cool operation that can provide additional
AC energy savings, especially during peak demand
periods.
A big idea in a small package.
The UltraMaxTM housing is smaller, lower-pro-
file and lightweight. That can be a big help in
retrofits. It also means future fixture designs can
be more compact and streamlined.
Every unit is tested and proven before
it’s shipped.
GE does 100% burn-in on every UltraMaxTM
ballast using our extreme open/short test, which
simulates undesirable and harsh-use situations, so
you are assured of a system you can rely on right
out of the box.
GE Six Sigma quality backed
by a full 5-year warranty.
UltraMaxTM is designed by GE’s expert engi-
neers and custom-manufactured to our exacting
Six Sigma specifications, all backed by a full 5-year
warranty.
COMPARE THE ENERGY USE
OF A THREE LAMP FIXTURE
1STANDARD T12/WM SYSTEM
2STANDARD ELECTRONIC
T8 SYSTEM
3ULTRAMAXTM L SYSTEM
WITH GE T8 WATT-MISER
117
watts 87
watts 68
watts
1 2 3
A FULL FAMILY OF HIGH
EFFICIENCY MULTI-VOLTAGE
BALLASTS FOR ALL T8
APPLICATIONS.
ULTRA
ELECTRONIC BALLAST
MAX
ULTRA
ELECTRONIC BALLAST
MAX
ULTRA
ELECTRONIC BALLAST
MAX
Applications:
Safety
No PCBs
UL Listed
- Class P, Type 1
- Type CC
- Type HL (Hazardous
Location)
Application Information
Minimum Starting
Temperature: 0°F, -18°C
Maximum Ambient
Temperature: 105°F, 40°C
Sound Rated A
Remote Mounting:
18' maximum lead length, 18
AWG
High Frequency Lamp
Operation: Above 60 kHz
Physical Parameters
(Except for the 4H model)
Length: 9.50 in.
Width: 1.70 in.
Height: 1.2 in.
Weight: 1.4 lbs.
Offices
Retail
Schools
Universities
Plants
Hotels
Warehouses
Hospitals
See for
yourself
how different
UltraMaxTM
ballasts perform.
BALLAST
FACTOR
*SYSTEM
LUMENS
(2850 Lumens/Lamp)
*INPUT
WATTS
LUMENS PER
WATT
* For a 2-Lamp F32T8 System at 277V
.77 4389 48 91
.87 4959 53 94
1.15 6555 73 90
L
N
H
For more information, visit www.gelighting.com
1-3
L
N
H
UltraMaxelectronic
ballasts have 5% more
energy efficiency than
standard electronic
ballasts. When
combined with
GE T8 Watt-
Miser®lamps,
it means up
to 40% in
energy savings.
ULTRA
ELECTRONIC BALLAST
MAX
ULTRA
ELECTRONIC BALLAST
MAX
transforming the power of light
1-4
A SMALLER, LOWER PROFILE DESIGN
IS A BIG IDEA FOR EFFICIENT
INSTALLATION.
PHYSICAL
DIMENSIONS
For Ballast types
L, N and H (except 4H)
OVERALL
DIMENSIONS
A(length)
8.375 in.
(21.273 cm)
B(width)
1.25 in.
(3.175 cm)
C(height)
1.125 in.
(2.858 cm)
MOUNTING
DIMENSIONS
D(length)
8.875 in.
(22.54 cm)
E(width)
1.4375 in.
(3.651 cm)
WEIGHT
RANGE
1.00 to 1.50 lbs.
(0.454 to 0.6804 kg.)
For more information, visit www.gelighting.com
1-5
ULTRAMAXTM
ELECTRONIC
BALLASTS
It’s easy to see how smaller, lower-profile
UltraMaxTM ballasts make even the toughest
retrofits into easy fits.
B
D
E
A
C
TRANSFORMING
THE
POWER
OF
LIGHT
NEW
WHEN YOU
WANT LIGHTING
DONE RIGHT
,
START WITH GE.
Up to 40% in
energy savings
One patented GE
ballast handles
120V through
277V
13 models can
replace more than
40 conventional
electronic ballasts
ULTRA
ELECTRONIC BALLAST
MAX
ULTRA
ELECTRONIC BALLAST
MAX
ULTRAMAXTM
ELECTRONIC
BALLASTS
ULTRAMAXTM
ELECTRONIC
BALLASTS
transforming the power of light
1-6 1-7
For more information, visit www.gelighting.com
CHOOSING THE RIGHT BALLAST IS SIMPLE.
The easy-to-understand model numbering system helps you choose and install the right model.
Instructions and wiring diagrams on each ballast label help assure a correct installation the first time.
TOTAL PERFORMANCE SYSTEMWARRANTY
Here are the facts behind the promise.
It starts with precision manufacturing.
GE UltraMaxTM Electronic Ballasts are custom-manufactured to our
exacting specifications. We work to assure you the
reliability and quality you expect from GE.
Manufacturing processes include rigorous testing and
quality control. Quality standards are further assurance
of trouble-free performance.
100% burn-in of units to assure reliability.
GE’s extreme open/short Test which tests units’
ability to withstand severe current conditions.
Careful component selection and extensive testing
of elements prior to final approval.
Critical component placement and extensive testing
of elements prior to final approval.
Extensive lamp/ballast system testing which ensure
optimal operating performance and compatibility.
Comprehensive testing under adverse field and
accelerated life conditions to prevent failure in the
field.
Commitment to Six Sigma standards for world-
class product and service excellence.
Power line voltage spike protection that passes
the IEEE surge test (where a 6000V pulse is
applied to input leads). Compliance with all
appropriate regulatory standards.
Contact your GE representitive for specific warranty details.
TRANSFORMING
THE
POWER
OF
LIGHT
UltraMax
TM
Total Performance System
Warranty
GE Lighting is pleased to provide the following warranty covering GE
T8 fluorescent lamps and GE UltraMax
TM
electronic ballasts.
GE Lighting warrants that lamps and ballasts comply with their respective published specifications and
are free from defects in material, workmanship and title.
This warranty only applies when GE lamps are operated on GE UltraMax
TM
electronic ballasts that
have been properly wired and installed; are operated within the electrical values shown on the ballast
label; used in lighting equipment designed and approved for the application; and environmental
conditions (temperature, humidity and air movement) are within the normal specified operating range of
the system.
If lamps in systems meeting the above requirements fail due to factors within the lamp during the
initial three (3) years or 10,500 hours of operation, whichever comes first, after the date of purchase,
GE Lighting agrees to furnish replacement lamps at no charge. This warranty applies to lamps which
are operated on a burning cycle of 10 hours/start or more.
If a GE UltraMaxTM electronic ballast fails due to factors within the ballast during the initial five (5)
years after the date of manufacture, GE Lighting, at its option, will at no charge either replace the
defective ballast including paying a labor allowance or refund the purchase price of the ballast.
GE Lighting reserves the right to examine failed lamps and/or ballasts to determine the cause of
failure and patterns of lamp usage. These lamp and ballast warranties do not apply to any abnormal
use or use in violation of any applicable standard, code or instructions for use in installations including
those contained in the National Electric Code (NEC), The Standards for Safety of Underwriters
Laboratory, Inc. (UL), Standards for the American National Standards Institute (ANSI) or, in Canada, the
Canadian Standards Association (CSA).
The foregoing shall constitute the exclusive remedy of the purchaser and the sole liability of GE
Lighting for lamp and ballast warranties. NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE IS MADE OR IS TO BE IMPLIED. In no event shall GE Lighting be liable for any
other cost of damages including lost profits, incidental, special or consequential damages.
Notes:
Light refers to "mean" lumen output relative to highlighted T12 Electromagnetic E.S. (energy saving) ballast systems.
RLPW is mean system Lumens/Watt relative to highlighted T12 Electromagnetic E.S. (energy saving) ballast systems.
Watts shown at 277 Volts.
SYSTEM PERFORMANCE COMPARISON MATRIX
Compare the overall performance of a GE UltraMaxTM system to conventional lamp and ballast systems.
2-Lamp System
Performance
4' Fluorescent
Electromagnetic E.S. Rapid Start Low Power (L) Normal UltraMax
TM
LUltraMax
TM
N UltraMax
TM
H
Watt-Miser T12 (CW) Watts: 74 Watts: 64 Not Available Not Available Not Available Not Available Not Available
BF: 0.90 BF: 0.86
Light: 100% Light: 96%
RLPW: 100% RLPW: 110%
F32T8 & F32T8/XL (SP) Watts: 69 Watts: 63 Watts: 51 Watts: 58 Watts: 48 Watts: 53 Watts: 73
BF: 0.88 BF: 0.88 BF: 0.78 BF: 0.88 BF: 0.77 BF: 0.87 BF: 1.15
Light: 116% Light: 116% Light: 103% Light: 116% Light: 102% Light: 115% Light: 152%
RLPW: 125% RLPW: 137% RLPW: 149% RLPW: 148% RLPW: 157% RLPW: 160% RLPW: 154%
F32T8/WM ULTRA & XL (SP) Not Not Watts: 48 Watts: 54 Watts: 46 Watts: 52 Watts: 70
Recommended Recommended BF: 0.78 BF: 0.88 BF: 0.77 BF: 0.87 BF: 1.15
Light: 102% Light: 115% Light: 100% Light: 113% Light: 150%
RLPW: 157% RLPW: 157% RLPW: 161% RLPW: 161% RLPW: 158%
3-Lamp System
Performance
4' Fluorescent
Electromagnetic E.S. Rapid Start Low Power (L) Normal UltraMax
TM
LUltraMax
TM
N UltraMax
TM
H
Watt-Miser T12 (CW) Watts: 117 Watts: 93 Not Available Not Available Not Available Not Available Not Available
BF: 0.91 BF: 0.86
Light: 100% Light: 95%
RLPW: 100% RLPW: 119%
F32T8 & F32T8/XL (SP) Watts: 105 Watts: 93 Watts: 77 Watts: 87 Watts: 72 Watts: 80 Watts: 109
BF: 0.88 BF: 0.88 BF: 0.78 BF: 0.88 BF: 0.77 BF: 0.87 BF: 1.15
Light: 115% Light: 115% Light: 102% Light: 115% Light: 101% Light: 114% Light: 150%
RLPW: 128% RLPW: 145% RLPW: 155% RLPW: 155% RLPW: 163% RLPW: 166% RLPW: 161%
F32T8/WM ULTRA & XL (SP) Not Not Watts: 72 Watts: 81 Watts: 68 Watts: 77 Watts: 104
Recommended Recommended BF: 0.78 BF: 0.88 BF: 0.77 BF: 0.87 BF: 1.15
Light: 101% Light: 113% Light: 99% Light: 112% Light: 148%
RLPW: 163% RLPW: 164% RLPW: 171% RLPW: 170% RLPW: 167%
4-Lamp System
Performance
4' Fluorescent
Electromagnetic E.S. Rapid Start Low Power (L) Normal UltraMax
TM
LUltraMax
TM
N UltraMax
TM
H
Watt-Miser T12 (CW) Watts: 148 Watts: 128 Not Available Not Available Not Available Not Available Not Available
BF: 0.90 BF: 0.86
Light: 100% Light: 96%
RLPW: 100% RLPW: 110%
F32T8 & F32T8/XL (SP) Watts: 138 Watts: 120 Watts: 100 Watts: 114 Watts: 96 Watts: 107 TBD
BF: 0.88 BF: 0.88 BF: 0.78 BF: 0.88 BF: 0.77 BF: 0.87
Light: 116% Light: 116% Light: 103% Light: 116% Light: 102% Light: 115%
RLPW: 125% RLPW: 143% RLPW: 152% RLPW: 151% RLPW: 158% RLPW: 159%
F32T8/WM ULTRA & XL (SP) Not Not Watts: 95 Watts: 107 Watts: 91 Watts: 103 TBD
Recommended Recommended BF: 0.78 BF: 0.88 BF: 0.77 BF: 0.87
Light: 102% Light: 115% Light: 100% Light: 113%
RLPW: 158% RLPW: 159% RLPW: 163% RLPW: 163%
Lamps Electromagnetic Ballasts Electronic Ballasts
ULTRA
ELECTRONIC BALLAST
MAX
The right ballast. The right performance. The right light.
1 = Maximum number of lamps supported by this ballast.
32 = Lamp watts (primary lamp)
N = Normal ballast (ballast factor of .87)
ULTRA
ELECTRONIC BALLAST
MAX
1-9
For more information, visit www.gelighting.com
ULTRAMAXTM
ELECTRONIC
BALLASTS
transforming the power of light
1-8
ORDERING GUIDE AND SYSTEM WATTAGE
There’s a combination of GE UltraMaxballasts and T8 lamps that can make virtually
any lighting system perform better. The chart below lets you see for yourself.
High Normal Low Power
# Lamps
Starting
Instant Start
Normal
Denotes standard laboratory non-fixture open bench testing.
In fixture watts represent typical field operating conditions with ballast and lamps in fixture/luminaire.
Open fixture denotes non-lensed fixture/luminaire. Enclosed fixture denotes lensed fixture/luminaire.
Units
Units
GE UltraMax Ballasts F32T8 Input Watts F32T8/WM Input Watts F28T8/WM Input Watts
Product Description Input Input In Fixture
Input In Fixture
Input Input Fixture
Per
Code Voltage WattsOpen Enclosed WattsOpen Enclosed WattsOpen Enclosed Case
149706 GE-132-MAX-L/Ultra Multi-Volt 120 25 24 24 24 23 23 22 TBD TBD 10
277 25 24 24 24 23 23 22 TBD TBD
249707 GE-232-MAX-L/Ultra Multi-Volt 120 48 48 47 46 46 45 44 TBD TBD 10
277 48 48 47 46 46 45 44 TBD TBD
349708 GE-332-MAX-L/Ultra Multi-Volt 120 73 72 71 69 68 67 65 TBD TBD 10
277 72 71 70 68 67 66 65 TBD TBD
449709 GE-432-MAX-L/Ultra Multi-Volt 120 97 95 93 92 90 88 87 TBD TBD 10
277 96 93 92 91 89 87 86 TBD TBD
149771 GE-132-MAX-N/Ultra Multi-Volt 120 28 28 27 27 26 26 25 TBD TBD 10
277 28 28 27 27 26 26 25 TBD TBD
249772 GE-232-MAX-N/Ultra Multi-Volt 120 54 54 53 53 52 51 49 TBD TBD 10
277 53 53 52 52 51 50 48 TBD TBD
349773 GE-332-MAX-N/Ultra Multi-Volt 120 82 80 78 78 77 74 72 TBD TBD 10
277 80 78 77 77 75 73 71 TBD TBD
449774 GE-432-MAX-N/Ultra Multi-Volt 120 109 105 103 105 101 98 98 TBD TBD 10
277 107 103 101 103 99 97 96 TBD TBD
249775 GE-232-MAX-H/Ultra Multi-Volt 120 74 71 69 71 69 67 66 TBD TBD 10
277 73 70 68 70 68 66 65 TBD TBD
349776 GE-332-MAX-H/Ultra Multi-Volt 120 111 105 102 106 102 97 97 TBD TBD 10
277 109 103 100 104 100 96 96 TBD TBD
449777 GE-432-MAX-H/Ultra Multi-Volt 120 151 TBD TBD 145 TBD TBD 133 TBD TBD 10
277 147 TBD TBD 141 TBD TBD 131 TBD TBD
GE UltraMax Ballasts F96T8 Input Watts F96T8/WM Input Watts
Product Description Input Input In Fixture
Input In Fixture
Per
Code Voltage WattsOpen Enclosed WattsOpen Enclosed Case
149766 GE-159-MAX-N/Ultra Multi-Volt 120 56 TBD TBD 54 TBD TBD 10
277 55 TBD TBD 53 TBD TBD
249767 GE-259-MAX-N/Ultra Multi-Volt 120 112 TBD TBD 107 TBD TBD 10
277 110 TBD TBD 105 TBD TBD
PRODUCT OVERVIEW
AccuStart® and Universal Voltage Low
Profile High Performance (HP-A & HP-B)
AccuStart® ballasts are ideal for frequently
switched applications or as a rapid start alternative.
They incorporate patented programmed rapid start
technology to properly heat the lamp filaments,
which yields an increase in lamp life up to 50%. The
1-4 lamp models offer universal input voltage.
Our low profile High Performance ballasts with
THD <10% offer the convenience of universal input
voltage (108-305 Volts) as a standard feature.
Universal input is "installer-friendly" – ensuring that
you have the right voltage ballast every time. Our low
profile models also feature a package and cross-sec-
tion that can offer greater flexibility in fixture design
(1.0" height x 1.5" width). Since the mounting and
wiring footprints are the same as a standard ballast,
our low profile HP models will easily retrofit into any
T12 or T8 fixture.
Low Profile Reduced Harmonic (RH-A)
Our low profile RH ballasts are over 45%
smaller and 30% lighter. They feature a space-sav-
ing package (1.18" height x 1.7" width) and cross
section for greater flexibility in fixture design. The
1-4 lamp model features parallel lamp operation,
with standard mounting footprint and wiring for
ease of replacement. They offer high efficiency
performance with THD <20%.
Low profile RH ballasts. AccuStart®ballasts for frequently
switched applications.
Flexible fixture design options for
T5 lamps.
PRODUCT OVERVIEW
transforming the power of light
1-10
ELECTRONIC
FLUORESCENT BALLASTS
1-11
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS
PRODUCT OVERVIEW
T5 systems are gaining greater popularity for
high-end architectural applications. GE provides a
wide range of T5 solutions, from 14 to 54 watts.
Our T5 ballasts operate multiple (1 or 2) F35T5,
F28T5, F21T5 and F14T5 lamps. Additionally, our
T5HO ballasts operate multiple (1 or 2) F54T5HO,
F39T5HO and F24T5HO lamps. Moreover, they
make your life easier with standard features that
include universal input voltage (108-305 Volts),
programmed rapid start technology for longer lamp
life and end of lamp life shutdown circuit with
auto-reset.
T5 Standard Output
Our standard output ballasts for T5 applica-
tions support multiple lamp operation (including
14, 21, 28, and 35 watts). They're ideal for indi-
rect pendant mount, surface mount, cove, under-
cabinet or task lighting. With a small cross section
(1.0"height x 1.18"width), our T5 models give
you more options for slim fixture design. Standard
features include universal input voltage, end-of-
lamp-life shutdown circuit and programmed rapid
start technology.
T5 High Output
High output T5 ballasts from GE support 24-,
39- and 54-watt lamps and they offer the same
standard features and compact dimensions as our T5
standard output. They're also well-suited to applica-
tions where space is at a premium, including slim
pendant mounted fixtures, cove and task lighting.
T5 BALLASTS FOR INDIRECT, HIGH-END
ARCHITECTURAL APPLICATIONS
NEC & UL Requirements
Ballast installation presents the possibility of
exposure to potentially hazardous voltages and
should be performed only by qualified personnel.
All installation, inspection, and maintenance should
be performed only with power to the fixture turned
off. Additionally, all fixtures and ballasts must be
installed and operated in compliance with the
National Electrical Code, Underwriters Laboratories
Inc. (UL) requirements, and all local applicable
codes and regulations.
Polarity
Polarity refers to the proper connection of bal-
last lead wires to line wires. To aid you in making a
correct installation, GE ballast leads are color-coded
for easy identification. The WHITE ballast lead is to
be connected to the neutral (grounded) and the
BLACK (or black with white tracer) lead always to
the phase (“hot”) line wire. Systems where neither
of the line wires are at ground potential require
specially designed ballasts. A change in polarity
may result in the voltage from the lead to the
ground exceeding UL-specified limits. In some types
of ballasts, a change in polarity may decrease volt-
age from the lead to the ground, thereby impeding
the starting dependability of the ballast.
Grounding
Ballast cases and fixtures must always be
grounded. The ballast case may be grounded to the
fixture or otherwise grounded. It could be haz-
ardous to make contact with an ungrounded fix-
ture or ballast when in operation. Neglecting to
properly ground the ballast and fixture combination
may also result in failure of certain lamps to start or
for unacceptable levels of electromagnetic noise to
be conducted onto the power lines.
Operating Line Voltage Limits
To receive the full benefits of rated lamp output
and to prolong ballast life, it is essential that volt-
age supplied to an installation be maintained with-
in limits prescribed for each circuit. These limits are
listed in the next column.
Subjecting a ballast to excessive voltage for an
extended period results in the deterioration of the
insulation. This insulation breakdown will cause
early ballast failure.
Low voltage has no damaging effect on the
ballast. However, lamps may not start reliably, and
early lamp failure could result.
Internal Ballast Protection
Class P Classification—Since January 1, 1984,
the National Electrical Code requires that “where
Fluorescent fixtures are installed indoors, the ballast
shall have thermal protection integral within the
ballast except for simple reactance ballasts.” This
ruling applies to replacement ballasts as well as to
those contained within new fixtures.
In compliance with the National Electrical Code,
UL has established a Class P ballast classification for
fluorescent light fixtures. A Class P ballast must
employ internal thermal protection limiting its oper-
ating temperature.
GE UL-approved Class P ballasts comply with
the National Electrical Code requirement and are
equipped with an automatic resetting thermal
protector, built-in and adjacent to the transformer
coils. The resetting thermal protector functions as
a thermostat, which will open and temporarily
deactivate the ballast when it exceeds the permis-
sible temperature. It will reset when the ballast
cools to a safe operating temperature. The ballast
will continue to cycle until the cause of overheat-
ing is eliminated. If the ballast is defective, it must
be replaced. If the cause is external, a Class P bal-
last will resume normal operation after abnormal
conditions are eliminated.
VOLTAGE RANGE
Nominal Voltage
120
220
277
347
120-277 (UNV)
Minimum
108
198
249
312
108
Maximum
132
242
305
382
305
SAFETY
APPLICATION AND
OPERATING
INFORMATION
APPLICATION AND
OPERATING
INFORMATION
1-13
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS
transforming the power of light
1-12
ELECTRONIC
FLUORESCENT BALLASTS
APPLICATION AND
OPERATING
INFORMATION
Dimming Ballasts - Ballastar®dimming ballasts
from GE are controlled by using 10-0vDC. Care
should be taken to ensure that the line voltage
(AC) wires are not connected to the low voltage
DC wires. Ballastar®electronic dimming ballasts
have protection (safety) circuitry that will sense the
error so as not to harm the installer or the ballast.
Dimming ballasts manufactured after May 1999
have the protection circuit. Dimming ballasts manu-
factured before this date do not have low voltage
circuit protection.
Fusing - Class P ballasts do not require fusing.
Fusing can be used when a single circuit has a
large number of fixtures/ballasts.
Grounding - ANSI C82.1 recommends all fixtures
and ballasts be grounded. GE requires all electronic
ballasts be grounded.
Thermal Protection - All GE electronic ballasts
meet UL 935 Standard for thermal protection.
These ballasts are designated Class P. A Class P
ballast will disconnect the ballast from input
power in the event of internal over-temperature.
SAFETY PERFORMANCE
Lamp Connections
Fluorescent ballasts are designed to generate
voltages in excess of 300 Volts. It is imperative
that proper connection to quality sockets be
assured in accordance with wiring diagrams on
each page of the catalog and on product labels.
Some applications may not require the use of all
of the ballast output leads. If any leads are not to
be connected, each should be individually capped
and insulated to at least 600 Volts.
Application Versatility
Many GE models are designed to allow for
applications with different types or quantities of
lamps. Lamp applications not listed on label cannot
be warranted.
Audible Noise (Sound)
Electrical equipment, including most
fluorescent lamp ballasts, produces some noise.
Care must be taken to select a ballast with the
proper sound rating for a particular lighting
installation. Secure mounting can reduce the
potential for audible noise. Typically, electronic
ballasts operate up to 75% quieter than
electromagnetic ballasts for fluorescent lamps.
Remote Mounting
Excessive hot or cold temperatures, audible
noise requirements, or a desire to operate lamps
in more than one fixture with the same ballast
(master/slave), may make it desirable to mount
the ballast remotely. Care must be taken to allow
for ballast heat dissipation and proper grounding.
In any application, the wire used to extend
leads must be at least as large as the wire sup-
plied on the ballast (18 AWG) with an insulation
rating of 1000 VAC at 90°C.
Lead lengths in excess of those noted, cause
loading effects that can dramatically impact bal-
last performance and void the warranty. GE T8
instant start and programmed (rapid) start elec-
tronic ballasts can be mounted remotely, from the
lamp sockets, up to 18 feet. GE T8 rapid start
electronic ballasts can be mounted remotely, from
the lamp sockets, up to 12 feet.
• Incorrect wiring
• Poor heat dissipation due to surrounding insu-
lation
• Sealed (Vapor Tight) Fixtures - Unusual heat
build-up due to lack of ventilation in fixtures
may cause thermal (on/off) cycling of certain
ballasts. Consult GE for specific
recommendations.
Recommendations:
• Selection of a proper ballast to match the
requirements of the lamp, fixture, voltage
and installation
• Mounting of ballast within the fixture with as
much surface contact as possible between
the ballast and metal portions of the
fixture.Secure mounting will aid in proper heat
dissipation and can minimize the potential for
ballast hum.
• The use of heat-conducting dissipators (radia-
tors), if necessary, which increases surface con-
tact between the ballast and fixture.
• If necessary, locate the ballast in a remote, cool-
er area outside the fixture.
• Consult GE for remote mounting recommen-
dations.
Starting Method Legend
IS=Instant Start
PRS=Programmed Rapid Start
RS=Rapid Start
PAR-IS=Parallel Instant Start
PAR-PRS=Parallel Programmed Rapid Start
PAR-RS=Parallel Rapid Start
SER-RS=Series Rapid Start
Lamp Starting Dependability
Fluorescent lamps are inherently more difficult
to start at low temperatures. All ballasts have limi-
tations as to their ability to start lamps at low
ambient temperatures. In this catalog, the low
starting point for each lamp/ballast combination
appears in the column marked “Minimum Starting
Temperature.”
Four lamp instant start ballasts can operate at a
minimum starting temperature down
to -18°C (0°F) under the following conditions:
1. Lead lengths to the lamps are those
supplied, by GE, with the ballast or shorter.
2. The distance from the lamp to the ground
plane is no greater than 3/4".
3. The line voltage supplied to the ballast is no
less than rated nominal.
4. The ballast or lamps are not remotely
mounted.
5. The lamps have been burned in per lamp
manufacturer requirements (typically 100
hours).
Contact GE for lamp operating characteristics and
requirments below 15°C (50°F).
Light Output
Optimum light output from fluorescent lamps
is achieved when the lamp wall is at 100-110°F.
Any substantial excursion (either colder or warmer)
will result in a reduction in light output.
Ballast Life
A fluorescent lamp ballast, like any other elec-
trical device, generates heat during its normal
operation. Ballast temperatures should be kept as
low as possible. Maximum dissipation of heat
through fixture design and proper ballast installa-
tion will help. Although excessive temperature
may not cause the ballast to fail immediately, it
can shorten ballast life. To assure maximum life,
the ballast case temperature should not exceed
75°C, in a maximum ambient (fixture cavity) of
40°C.
Causes of ballast overheating:
• Incorrect line voltage or frequency
• Incorrect size, type or number of lamps
PERFORMANCE, continued
TYPICAL
SPECIFICATIONS
TYPICAL
SPECIFICATIONS
transforming the power of light
1-14 1-15
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS ELECTRONIC
FLUORESCENT BALLASTS
TYPICAL SPECIFICATIONS FOR INSTANT START
BALLASTS FOR:
• RH (Reduced Harmonics)
• L (Low Wattage)
• RHH (Reduced Harmonics High Light)
TYPICAL SPECIFICATIONS FOR INSTANT START
BALLASTS FOR:
Universal Voltage Performance
•HP(High Performance)
1. Ballasts (1-4 lamp) shall operate as a Parallel Circuit,
allowing remaining lamp(s) to maintain full light
output if one or more lamps fail.
2. Ballasts shall operate from 60 Hz input source of
120, 277 Volts, and sustained variations of ±10%
(Voltage & Frequency) with no damage to the
ballasts.
3. Ballasts shall be a high frequency electronic type,
and operate lamps at a frequency above 20 kHz.
4. Lamp Current Crest Factor (ratio of peak to RMS
current) shall be 1.7 or less in accordance with
lamp manufacturer recommendation and ANSI
C82.11-1993.
5. Ballasts shall tolerate operation in ambient
temperatures up to 105°F (40°C) without damage.
6. Ballasts shall comply with FCC Part 18 Non-
Consumer Equipment for EMI (power line
conducted) and RFI (Radiated).
7. Ballasts shall provide transient immunity as
recommended by ANSI C62.41-1991, Location A2.
8. Ballasts shall operate lamps with no visible
flicker (< 3% flicker index).
9. Ballasts shall tolerate sustained open circuit and
short circuit output conditions without damage.
10. Ballasts shall be Underwriters Laboratory
(UL 935) listed, Class P, Type 1 Outdoor, and
CSA certified where applicable.
11. Ballast shall have a Ballast Factor greater than .85
per ANSI C82.11-1993. Ballast Factor for Low Power (L)
models shall be greater than .77.
12. Input current Total Harmonic Distortion shall
not exceed 20% for the primary lamp applications.
13. Ballasts shall have a Power Factor greater than
.95 for primary lamp applications.
14. The ballasts do not contain any PCBs.
15. The manufacturer shall provide written warranty
against defects in material or workmanship,
including replacement, for five years from date
of manufacture.
16. Ballast shall be manufactured in an ISO 9001
Certified Facility.
17. Ballasts shall provide instant starting sequence
consistent with ANSI standard C82.11-1993.
18. GE model __________________ (or approved equal).
1. Ballasts (1-4 lamp) shall operate as a Parallel Circuit,
allowing remaining lamp(s) to maintain full light
output if one or more lamps fail.
2. Ballasts shall operate from 50/60 Hz input source of
120 through 277 Volts, and sustained variations of
±10% (Voltage & Frequency) with no damage to
the ballasts.
3. Ballasts shall be a high frequency electronic type,
and operate lamps at a frequency above 42 kHz to
minimize interference with infrared control systems.
4. Lamp Current Crest Factor (ratio of peak to RMS
current) shall be 1.7 or less in accordance with lamp
manufacturer recommendation and ANSI C82.11-
1993.
5. Ballasts shall tolerate operation in ambient tempera-
tures up to 105°F (40°C) without damage.
6. Ballasts shall comply with FCC Part 18 Non-
Consumer Equipment for EMI (power line
conducted) and RFI (Radiated).
7. Ballasts shall provide transient immunity as
recommended by ANSI C62.41-1991, Location A2.
8. Ballasts shall operate lamps with no visible flicker
(<3% flicker index).
9. Ballasts shall tolerate sustained open circuit and
short circuit output conditions without damage.
10. Ballasts shall be Underwriters Laboratory UL 935)
listed, Class P, Type 1 Outdoor, and CSA certified
where applicable.
11. Ballast shall have a Ballast Factor greater than .85
per ANSI C82.11-1993.
12. Input current Total Harmonic Distortion shall not
exceed 10% for the primary lamp.
13. Ballasts shall have a Power Factor greater than .98
for primary lamp.
14. The ballasts shall not have any PCBs.
15. The manufacturer shall provide written warranty
against defects in material or workmanship,includ-
ing replacement, for five years from date of manu-
facture.
16. Manufacturer shall have been manufacturing elec-
tronic ballasts for at least fifteen years.
17. Ballast shall be manufactured in an ISO 9001
Certified Facility.
18. Ballasts shall provide instant starting sequence con-
sistent with ANSI standard C82.11-1993.
19. Ballast shall be Bx32IUNVHP-B (x=1 or 2) or
Bx32IUNVHP-A (x=3 or 4) depending upon the
quantity of lamps per fixture.
20. GE model ______________ (or approved equal).
TYPICAL SPECIFICATIONS FOR ULTRAMAX
MULTI-VOLTAGE, INSTANT START, HIGH
EFFICIENCY BALLASTS
Section I – Physical Characteristics
1.1 The electronic ballast shall be physically
interchangeable with standard electromagnetic and
standard electronic ballast.
1.2 The electronic ballast shall have a maximum height of
1.2 in. and maximum weight of 1.5 lbs. (except 4H).
1.3 The electronic ballast shall be furnished with integral
leads, color-coded to ANSI C82.11.
Section II – Performance Requirements
2.1 The electronic ballast shall operate throughout wide
range of input line voltage 120-277 Volts, with
+/-10% variation tolerance 50/60 Hz for Multi Voltage
Control /Universal Voltage.
2.2 Ballast shall be classified “hi-efficiency” and shall
provide a minimum of 3 watts energy savings over
comparable standard electronic ballasts.
2.3 The electronic ballast input current shall have Total
Harmonic Distortion (THD) of less than 10% when
used with the primary lamp at 120 Volts. It shall be
less than 20% on other approved lamps.
2.4 The electronic ballast shall have a Power Factor greater
than 98% when used with primary lamp at 120
Volts and greater than 95% at 277 Volts.
2.5 The electronic ballast shall be Sound Rated A.
2.6 The electronic ballast output frequency to the lamps
shall be above 60 kHz to minimize interference with
infrared control systems and eliminate visible flicker.
2.7 The electronic ballast shall meet ANSI C82.11 for
Electronic Ballast Performance.
2.8 The electronic ballast shall withstand transients
specified in ANSI C62.41, Location Category A3.
2.9 The electronic ballast shall be Instant Start with
independent parallel lamp operation.
2.10 The electronic ballast shall have a Lamp Current Crest
Factor of <1.5.
2.11 Lamps may be remote or tandem mounted up to a
maximum of 18ft. overall lead length between ballasts
and lamps.
2.12 Ballast shall have a minimum starting temperature of
0ºF for F32T8, F25T8 and F17T8.
Section III – Regulatory
3.1 The electronic ballast shall meet the requirements
of the Federal Communications Commission rules
and regulations, Title 47 CFR part 18, for Non-
Consumer equipment.
3.2 The electronic ballast shall comply with all
applicable state and federal efficiency standards.
3.3 The electronic ballast shall be Underwriters
Laboratories (UL) Listed Class P & Type HL.
3.4 The electronic ballast shall provide UL Class CC,
Closed Cabinet protection to prevent ignition of
non-UL–controlled thermoplastic diffuser and
overheating of bi-pin lampholders.
Section IV – Other
4.1 The electronic ballast shall not contain
Polychlorinated Biphenyl (PCBs).
4.2 The electronic ballast shall carry a five year warranty
form the date of manufacture. Warranty shall be
valid for maximum case temperature of 70ºC.
4.3 The electronic ballast shall eliminate lamp striation
(spiraling effect).
4.4 The electronic ballast shall be available in 1, 2, 3, &
4 lamp versions for F32T8 and 1 & 2 lamp versions
for F96T8.
4.5 The F32T8 electronic ballast shall be available with
Ballast Factor of .77 Low, .87 Normal, and 1.15
High Power.
4.6 The electronic ballast shall have constant Ballast
Factor if one or more lamps fail.
TYPICAL
SPECIFICATIONS
1-17
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS
TYPICAL
SPECIFICATIONS
transforming the power of light
1-16
ELECTRONIC
FLUORESCENT BALLASTS
1. Ballasts (1-4 lamp) shall operate as a Parallel Circuit,
allowing remaining lamp(s) to maintain full light
output if one or more lamps fail (except T12 High
Output).
2. Ballasts shall operate from 50/60 Hz input source
of 120, 277, and 347 Volts, and sustained
variations of 10% (Voltage & Frequency) with no
damage to the ballasts.
3. Ballasts shall be a high frequency electronic type,
and operate lamps at a frequency above 20 kHz.
4. Lamp Current Crest Factor (ratio of peak to RMS
current) shall be 1.7 or less in accordance with
lamp manufacturer recommendation and ANSI
C82.11-1993.
5. Ballasts shall tolerate operation in ambient
temperatures up to 105°F (40°C) without
damage. Ballasts shall comply with FCC Part 18
Non-Consumer Equipment for EMI (power line
conducted) and RFI (Radiated).
6. Ballasts shall provide transient immunity as
recommended by ANSI C62.41-1991, Location A2.
7. Ballasts shall operate lamps with no visible flicker
(< 3% flicker index).
8. Ballasts shall tolerate sustained open circuit and
short circuit output conditions without damage.
9. Ballasts shall be Underwriters Laboratory (UL 935)
listed, Class P, Type 1 Outdoor, and CSA certified
where applicable.
10. Ballast shall have a Ballast Factor greater than .85
per ANSI C82.11-1993. Ballast Factor for Low
Power (L) models shall be greater than .77.
11. Input current Total Harmonic Distortion shall not
exceed 10% for the primary lamp.
12. Ballasts shall have a Power Factor greater than
.98 for primary lamp.
13. The ballasts do not contain any PCBs.
14. The manufacturer shall provide written warranty
against defects in material or workmanship,
including replacement, for five years from date of
manufacture.
15. Ballast shall be manufactured in an ISO 9001
Certified Facility.
16. Ballasts shall provide instant starting sequence
consistent with ANSI standard C82.11-1993.
17. GE model__________________(or approved equal).
1. Ballasts (1-4 lamp) shall operate as a Parallel Circuit,
allowing remaining lamp(s) to maintain full light
output if one or more lamps fail (except T12 High
Output).
2. Ballasts shall operate from 60 Hz input source of
120, 277 Volts, and sustained variations of ±10%
(Voltage & Frequency) with no damage to the
ballasts.
3. Ballasts shall be a high frequency electronic type,
and operate lamps at a frequency above 20 kHz.
4. Lamp Current Crest Factor (ratio of peak to RMS
current) shall be 1.7 or less in accordance with
lamp manufacturer recommendation and ANSI
C82.11-1993.
5. Ballasts shall tolerate operation in ambient
temperatures up to 105°F (40°C) without damage.
6. Ballasts shall comply with FCC Part 18 Non-
Consumer Equipment for EMI (power line
conducted) and RFI (Radiated).
7. Ballasts shall provide transient immunity as
recommended by ANSI C62.41-1991, Location A2.
8. Ballasts shall operate lamps with no visible flicker
(< 3% flicker index).
9. Ballasts shall tolerate sustained open circuit and
short circuit output conditions without damage.
10. Ballasts shall be Underwriters Laboratory (UL 935)
listed, Class P, Type 1 Outdoor, and CSA certified
where applicable.
11. Ballast shall have a Ballast Factor greater than
.85 per ANSI C82.11-1993.
12. Input current Total Harmonic Distortion shall not
exceed 10% for the primary lamp applications.
13. Ballast shall be manufactured in an ISO 9001
Certified Facility.
14. Ballasts shall have a Power Factor greater than
.98 primary applications.
15. The ballasts do not contain any PCBs.
16. The manufacturer shall provide written warranty
against defects in material or workmanship,
including replacement, for five years from date
of manufacture.
17. Ballasts shall provide rapid starting sequence
consistent with ANSI standard C82.11-1993.
18. GE model_________________ (or approved equal).
1. Ballasts shall have a minimum start temperature
of 0°F.
2. Ballasts shall operate from a 50/60 Hz input source
of 120 through 277 Volts, and sustained variations
of ±10% (Voltage & Frequency) with no damage
to the ballasts.
3. Ballasts shall be a high frequency electronic type,
and operate lamps at a frequency above 42 kHz
to minimize interference with infrared control
systems.
4. Lamp Current Crest Factor (ratio of peak to RMS
current) shall be 1.7 or less in accordance with
lamp manufacturer recommendation and ANSI
C82.11-1993.
5. Ballasts shall tolerate operation in ambient
temperatures up to 105°F (40°C) without damage.
6. Ballasts shall comply with FCC Part 18 Non-
Consumer Equipment for EMI (power line
conducted) and RFI (Radiated).
7. Ballasts shall provide transient immunity as
recommended by ANSI C62.41-1991, Location A2.
8. Ballasts shall operate lamps with no visible flicker
(<3% flicker index).
9. Ballasts shall tolerate sustained open circuit and
short circuit output conditions without damage.
10. Ballasts shall be Underwriters Laboratory (UL 935)
listed, Class P, Type 1 Outdoor, and CSA certified
where applicable.
11. Ballast shall have a Ballast Factor greater than .85,
per ANSI C82.11-1993.
12. Input current Total Harmonic Distortion shall not
exceed 10%.
13. Ballasts shall have a Power Factor greater than
.98, for primary application.
14. The ballasts shall not have any PCBs.
15. The manufacturer shall provide written warranty
against defects in material or workmanship,
including replacement, for five years from date
of manufacture.
16. Ballast shall be manufactured in an ISO 9001
Certified Facility.
17. Ballast shall be manufactured in North America.
18. Ballast shall be GE AccuStart HP Product
Bx32PUNVHP-A (x=1,2,3, or 4).
19. GE model ______________ (or approved equal).
1. Ballast shall be Programmed Rapid Start.
2. Ballast shall incorporate lamp shutdown circuitry
for end of lamp life protection.
3. Ballast shall allow for re-lamping without the need
to cycle power.
4. Ballasts shall operate from 50/60 Hz input source
of 108-305 Volts, with no damage to the ballasts.
5. Ballasts shall be a high frequency electronic type,
and operate lamps at a frequency above 20 kHz.
6. Lamp Current Crest Factor (ratio of peak to RMS
current) shall be 1.7 or less in accordance with
lamp manufacturer recommendation and ANSI
C82.11-1993.
7. Ballasts shall tolerate operation in ambient
temperatures up to 105°F (40°C) without damage.
8. Ballasts shall comply with FCC Part 18 Non-
Consumer Equipment for EMI (power line
conducted) and RFI (Radiated).
9. Ballasts shall provide transient immunity as
recommended by ANSI C62.41-1991, Location A2.
10. Ballasts shall operate lamps with no visible flicker
(< 3% flicker index).
11. Ballasts shall tolerate sustained open circuit and
short circuit output conditions without damage.
12. Ballasts shall be Underwriters Laboratory (UL 935)
listed, Class P, Type 1 Outdoor, and CSA certified
where applicable.
13. Ballast shall have a Ballast Factor greater than .95
per ANSI C82.11-1993.
14. Input current Total Harmonic Distortion shall not
exceed 10% for the primary lamp.
15. Ballasts shall have a Power Factor greater than .98.
16. The ballasts do not contain any PCBs.
17. The manufacturer shall provide written warranty
against defects in material or workmanship,
including replacement, for five years from date
of manufacture.
18. Ballast shall be manufactured in and ISO 9001
Certified Facility.
19. GE model ________________ (or approved equal).
TYPICAL SPECIFICATIONS FOR INSTANT
START BALLASTS FOR:
•HP(High Performance)
HPL (High Performance Low Power)
HPH (High Performance High Light)
TYPICAL SPECIFICATIONS FOR RAPID START
BALLASTS
TYPICAL SPECIFICATIONS FOR PROGRAMMED
(RAPID) START BALLASTS
TYPICAL SPECIFICATIONS FOR T5 AND T5
HIGH OUTPUT (HO) BALLASTS
BALLAST MATRIX
1-19
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS
BALLAST MATRIX
transforming the power of light
1-18
ELECTRONIC
FLUORESCENT BALLASTS
BALLAST MATRIX
1L0.77 49706 GE-132-MAX-L/Ultra Multi-Volt
2L0.77 49707 GE-232-MAX-L/Ultra Multi-Volt
3L0.77 49708 GE-332-MAX-L/Ultra Multi-Volt
4L0.77 49709 GE-432-MAX-L/Ultra Multi-Volt
1N0.87 49771 GE-132-MAX-N/Ultra Multi-Volt
2N0.87 49772 GE-232-MAX-N/Ultra Multi-Volt
3N0.87 49773 GE-332-MAX-N/Ultra Multi-Volt
4N0.87 49774 GE-432-MAX-N/Ultra Multi-Volt
2H1.15 49775 GE-232-MAX-H/Ultra Multi-Volt
3H1.15 49776 GE-332-MAX-H/Ultra Multi-Volt
4H1.15 49777 GE-432-MAX-H/Ultra Multi-Volt
1N0.88 47532 B132PUNVHP-A Multi-Volt
2N0.88 47533 B232PUNVHP-A Multi-Volt
3N0.88 41008 B332PUNVHP-B Multi-Volt
4N0.88 41009 B432PUNVHP-B Multi-Volt
2N0.88 80355 B232SR120V5
80356 B232SR277V5
3N0.88 80357 B332SR120V5
80358 B332SR277V5
1N0.87 49766 GE-159-MAX-N/Ultra Multi-Volt
2N0.87 49767 GE-259-MAX-N/Ultra Multi-Volt
2H1.15 TBA GE-259-MAX-H/Ultra Multi-Volt
1N0.93 80286 B286I120RH
80287 B286I277RH
2N0.88 80286 B286I120RH
80287 B286I277RH
GE Electronic Ballasts
Ballast Product Input
Factor Code Description Voltage
GE Ballast Cross Reference for T8 Lamps
GE/Universal Ltg. Technologies (Magnetek)
Std. RH HP High Efficiency
GE Ballast Cross Reference for T8 Lamps
Advance Sylvania
Std. Discrete Centium High Efficiency Std. Quicktronic QT PRO
Lamp
Starting
Power
# Lamps
8-Ft. HO 8-Ft. T8 F96 Four-Foot T8, F32, F32/U, F25, F17, F32WM
IS-(vs-Rs) Instant Start Dimming Program Rapid Start Instant Start
Standard High Standard Standard Standard High Standard Low Power
Power
Starting
Lamp
8-Ft. HO 8-Ft. T8 F96 Four-Foot T8, F32, F32/U, F25, F17, F32WM
IS-vs-RS Instant Start Dimming Program Rapid Start Instant Start
Standard High Standard Standard Standard High Standard Low Power
REL-1P32-LW-SC ROP-2P32-LW-SC QTP1x32T8/120 RSL-A
VEL-1P32-LW-SC VOP-2P32-LW-SC QTP1x32T8/277 RSL-A
REL-2P32-LW-SC RCN-2P32-LW ROP-2P32-LW-SC QT2x32/120LP QTP2x32T8/120 RSL-A
VEL-2P32-LW-SC VCN-2P32-LW VOP-2P32-LW-SC QT2x32/277LP QTP2x32T8/277 RSL-A
REL-3P32-LW-SC RCN-3P32-LW ROP-2P32-LW-SC QT3x32/120LP QTP3x32T8/120 RSL-A
VEL-3P32-LW-SC VCN-3P32-LW VOP-2P32-LW-SC QT3x32/277LP QTP3x32T8/277 RSL-A
REL-4P32-LW-SC RCN-4P32-LW ROP-2P32-LW-SC QT4x32/120LP QTP4x32T8/120 RSL-A
VEL-4P32-LW-SC VCN-4P32-LW VOP-2P32-LW-SC QT4x32/277LP QTP4x32T8/277 RSL-A
REL-1P32-SC RCN-1P32-SC ROP-2P32-SC QT1x32/120IS-SC QTP1x32T8/120 ISN-D
VEL-1P32-SC VCN-1P32-SC VOP-2P32-SC QT1x32/277IS-SC QTP1x32T8/277 ISN-D
REL-2P32-SC RCN-2P32-SC ROP-2P32-SC QT2x32/120IS-SC QTP2x32T8/120 ISN-D
VEL-2P32-SC VCN-2P32-SC VOP-2P32-SC QT2x32/277IS-SC QTP2x32T8/277 ISN-D
REL-3P32-SC RCN-3P32-SC ROP-2P32-SC QT3x32/120ISN-SC QTP3x32T8/120 ISN-A
VEL-3P32-SC VCN-3P32-SC VOP-2P32-SC QT3x32/277ISN-SC QTP3x32T8/277 ISN-A
REL-4P32-SC RCN-4P32-SC ROP-2P32-SC QT4x32/120ISN-SC QTP4x32T8/120 ISN-A
VEL-4P32-SC VCN-4P32-SC VOP-2P32-SC QT4x32/277ISN-SC QTP4x32T8/277 ISN-A
REL-2P32-HL-SC QT2x32/120PLUS
VEL-2P32-HL-SC QT2x32/277PLUS
REL-3P32-HL-SC QT3x32/120PLUS
VEL-3P32-HL-SC QT3x32/277PLUS
RCN-1S32-SC QTP1x32T8/120 PSN-F
VCN-1S32-SC QTP1x32T8/277 PSN-F
RCN-2S32-SC QTP2x32T8/120 PSN-F
VCN-2S32-SC QTP2x32T8/277 PSN-F
RCN-3S32-SC QTP3x32T8/120 PSN-SC
VCN-3S32-SC QTP3x32T8/277 PSN-SC
RCN-4S32-SC QTP4x32T8/120 PSN-SC
VCN-4S32-SC QTP4x32T8/277 PSN-SC
RZT-2S32 QT2x32/120DIM5-B
VZT-2S32 QT2x32/277DIM5-B
RZT-3S32 QT3x32/120DIM5-Q
VZT-3S32 QT3x32/277DIM5-Q
REL-2P59-S-RH-TP RCN-2P59
VEL-2P59-S-RH-TP VCN-2P59
REL-2P59-S-RH-TP RCN-2P59 QT2x59/120IS QTP2x59T8/120 ISN-A
VEL-2P59-S-RH-TP VCN-2P59 QT2x59/277IS QTP2x59T8/277 ISN-A
REL-2P59-HL QT2x59/120PLUS
VEL-2P59-HL QT2X59/277PLUS
RCN-2S86
VCN-2S86
REL-2S86 series RS RCN-2S86
VEL-2S86 series RS VCN-2S86
B132IUNVHP-B
B232IUNVHP-B
B332IUNVHP-A
B432IUNVHP-A
B132PUNVHP-A
B232PUNVHP-A
B332PUNVHP-B
B432PUNVHP-B
B259IUNVHP
120
277
120 B232I120L-A B232I120EL/Ultra
277 B232I277L-A B232I277EL/Ultra
120 B332I120L-A B332I120EL/Ultra
277 B332I277L-A B332I277EL/Ultra
120 B432I120L-A B432I120EL/Ultra
277 B432I277L-A B432I277EL/Ultra
120 B132I120RH-A
277 B132I277RH-A
120 B232I120RH-A B232I120HE/Ultra
277 B232I277RH-A B232I277HE/Ultra
120 B332I120RH-A B332I120HE/Ultra
277 B332I277RH-A B332I277HE/Ultra
120 B432I120RH-A B432I120HE/Ultra
277 B432I277RH-A B432I277HE/Ultra
120 B232I120RHH B232I120HPH
277 B232I277RHH B232I277HPH
120 B332I120RHH
277 B332I277RHH
120
277
120 B132P120RH
277 B132P277RH
120 B232P120RH
277 B232P277RH
120 B332P120RH
277 B332P277RH
120 B432P120RH
277 B432P277RH
Varible dimming 3-level switch dim
120 B232SR120V5 B232SR120S30
277 B232SR277V5 B232SR277S30
120 B332SR120V5 B332SR120S30
277 B332SR277V5 B332SR277S30
120 B159I120RH
277 B159I277RH
120 B259I120RH B259I120HE/Ultra
277 B259I277RH B259I277HE/Ultra
120 B232I120RHH B232I120HPH
277 B232I277RHH B232I277HPH
120 B286I120RH
277 B286I277RH
120 B286I120RH
277 B286I277RH
F25T8
1-21
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS
transforming the power of light
1-20
ELECTRONIC
FLUORESCENT BALLASTS
F17T8
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F17T8 - One Lamp Applications
120 0.14 >.99 1.05 <10
49771 1 IS GE-132-MAX-N/Ultra • 17 0/-18 1A -A
277 0.07 >.90 1.05 <22
120 0.15 >.99 <10
47532 1 PRS B132PUNVHP-A • 17 0.91 0/-18 2 -A
277 0.07 >.96 <15
F17T8 - Two Lamp Applications
120 0.24 28 >.99 <12
49707 GE-232-MAX-L/Ultra .95 0/-18 1B -A
277 0.11 29 >.93 <24
120 0.27 >.99 <10
49772
2PAR-IS
GE-232-MAX-N/Ultra • 32 1.05 0/-18 1B -A
277 0.12 >.94 <20
120 0.28 >.99 <10
47533 2 SER-PRS B232PUNVHP-A 34 0.95 0/-18 30 -A
277 0.13 >.95 <15
F17T8 - Three Lamp Applications
120 0.35 >.99 <10
49708 GE-332-MAX-L/Ultra 42 0.95 0/-18 1C -A
277 0.16 >.96 <19
120 0.40 >.99 <10
49773
3PAR-IS
GE-332-MAX-N/Ultra • 48 1.05 0/-18 1C -A
277 0.18 >.97 <17
120 0.40 >.98
41008 3 SER-PRS B332PUNVHP-A 48 0.92 <10 0/-18 23 -A
277 0.19 >.90
F17T8 - Four Lamp Applications
120 0.47 >.99 <10
49709 GE-432-MAX-L/Ultra 56 0.95 0/-18 1D -A
277 0.21 >.96 <19
120 0.54 65 >.99 <10
49774
4PAR-IS
GE-432-MAX-N/Ultra • 1.05 0/-18 1D -A
277 0.24 64 >.97 <18
120 0.57 67 >.90 0.92 <25 0/-18 8 ST
41009 4 SER-PRS B432PUNV-HP-B
277 0.24 67 >.90 0.92 <25 0/-18 8 ST
FOR (1), (2), (3) & (4)
F17T8 LAMPS
CUS
DIMENSIONS
Overall Dimensions Mounting Dimension
Draw # L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
-A 9.50” 1.70” 1.18” 8.89” 1.69”
-B 9.50” 1.50” 1.00” 8.89” 0.88”
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F25T8 - One Lamp Applications
120 0.18 >.99 <10
49706 GE-132-MAX-L/Ultra 21 0.94 0/-18 1A -A
277 0.08 >.92 <20
120 0.24 23 >.99 <10
49771
1IS
GE-132-MAX-N/Ultra • 0.94 0/-18 1A -A
277 0.09 24 >.93 <18
120 0.20 >.99
47532 1 PRS B132PUNVHP-A • 24 0.91 <10 0/-18 2 -A
277 0.09 >.98
F25T8 - Two Lamp Applications
120 0.34 >.99 <10
49707 GE-232-MAX-L/Ultra 40 0.84 0/-18 1B -A
277 0.15 >.96 <19
2PAR-IS 120 0.21 53 >.96 0.87 <15
49772 GE-232-MAX-N/Ultra • 0/-18 1B -A
277 0.38 45 >.99 0.94 <10
120 0.40 47 >.99
47533 2 SER-PRS B232PUNVHP-A
277 0.17 46 >.97 0.94 <10 0/-18 30 -A
F25T8 - Three Lamp Applications
120 0.50 60 >.99 <10
49708 GE-332-MAX-L/Ultra 0.84 0/-18 1C -A
277 0.22 59 >.97 <14
120 0.56 67 >.99 <10
49773 GE-332-MAX-N/Ultra • 0.94 0/-18 1C -A
3PAR-IS
277 0.24 66 >.98 <13
80136 347 B332I347HP 0.20 68 >.99 0.91 <10 0/-18 6 ST
41008 120 0.77 92 >.99
3SER-PRS 277 B332PUNVHP-A • 0.33 89 >.95 .89 <10 0/-18 8 -A
F25T8 - Four Lamp Applications
120 0.67 80 >.99 <10
49709 GE-432-MAX-L/Ultra • 0.84 0/-18 1D -A
277 0.30 79 >.97 <15
120 0.76 91 >.99 <10
49774 4 PAR-IS GE-432-MAX-N/Ultra • 0.94 0/-18 1D -A
277 0.33 89 >.98 <14
120 0.77 92 >.99
41009 4 SER-PRS B432PUNVHP-A 0.89 <10 0/-18 8 -A
277 0.33 89 >.95
FOR (1), (2), (3) & (4)
F25T8 LAMPS
CUS
DIMENSIONS
Overall Dimensions Mounting Dimension
Draw # L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
-A 9.50” 1.70” 1.18” 8.89” 1.69”
-B 9.50” 1.50” 1.00” 8.89” 0.88”
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
1-23
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS
transforming the power of light
1-22
ELECTRONIC
FLUORESCENT BALLASTS
F32T8 & F32T8/WM
F28T8
DIMENSIONS
Overall Dimensions Mounting Dimension
Draw # L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
-A 9.50” 1.70” 1.18” 8.89” 1.69”
-B 9.50” 1.50” 1.00” 8.89” 0.88”
DIMENSIONS
Overall Dimensions Mounting Dimension
Draw # L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
-A 9.50” 1.70” 1.18” 8.89” 1.69”
-B 9.50” 1.50” 1.00” 8.89” 0.88”
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F28T8 - One Lamp Applications
120
49706 GE-132-MAX-L/Ultra • TBD 22 TBD TBD TBD TBD 1A -A
277
120
49771
1IS
GE-132-MAX-N/Ultra • TBD 25 TBD TBD TBD TBD 1B -A
277
F28T8 - Two Lamp Applications
120
49707 GE-232-MAX-L/Ultra • TBD 44 TBD TBD TBD TBD 1B -A
277
120 49
49772 2 PAR-IS GE-232-MAX-N/Ultra • • TBD TBD TBD TBD TBD 1B -A
277 48
120 66
49775 GE-232-MAX-H/Ultra • • TBD TBD TBD TBD TBD 1B -A
277 65
F28T8 - Three Lamp Applications
120
49708 GE-332-MAX-L/Ultra • TBD 65 TBD TBD TBD TBD 1C -A
277
120 72
49773 GE-332-MAX-N/Ultra • TBD TBD TBD TBD TBD 1C -A
277 71
120 97
49776
3PAR-IS
GE-332-MAX-H/Ultra • TBD TBD TBD TBD TBD 1C -A
277 96
F28T8 - Four Lamp Applications
120 87
49709 GE-432-MAX-L/Ultra • TBD TBD TBD TBD TBD 1D -A
277 86
120 98
49774 4 PAR-IS GE-432-MAX-N/Ultra • TBD TBD TBD TBD TBD 1D -A
277 96
120 133
49777 GE-432-MAX-H/Ultra • TBD TBD TBD TBD TBD TBD ST
277 131
FOR (1), (2), (3) & (4) F28T8 LAMPS
(F28T8/UMX – GE ULTRAMAX SYSTEM)
CUS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F32T8 - One Lamp Applications
120 0.22 >.99 <10
49706 GE-132-MAX-L/Ultra • 25 0.77 0/-18 1A -A
277 0.10 >.94 <18
120 0.42 >.99 <10
49771 GE-132-MAX-N/Ultra • 28 0.87 0/-18 1A -A
277 0.19 >.98 <15
1IS
120 0.24 28 >.99 <10
49707 GE-232-MAX-L/Ultra 0.87 0/-18 1B -A
277 0.11 29 >.93 <23
120 0.26 >.99 <10
49772 GE-232-MAX-N/Ultra • 31 0.87 0/-18 1B -A
277 0.12 >.94 <20
120 0.26 31 >.99
47532 B132PUNVHP-A • 0.88 <10 0/-18 2 -A
277 0.11 30 >.98
120 0.27 >.99 <10
47533
1PRS
B232PUNVHP-A • 32 1.00 0/-18 30 -A
277 0.12 >.95 <15
FOR (1) F32T8 LAMP
CUS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F32T8/WM - One Lamp Applications
120 0.21 >.99 <10
49706 GE-132-MAX-L/Ultra • 24 0.77 0/-18 1A -A
277 0.09 >.93 <18
120 0.22 26 >.99 <11
49707 GE-232-MAX-L/Ultra • 0.87 0/-18 1B -A
277 0.11 27 >.93 <25
120 0.25 >.99 <10
49772
1IS
GE-232-MAX-N/Ultra • 29 0.87 0/-18 1B -A
277 0.12 >.94 <21
120 0.23 >.99
47532 1 SER-PRS B132PUNVHP-A 28 0.88 <10 60/16 2 -A
277 0.10 >.98
FOR (1) F32T8/WM LAMP
CUS
F32T8 & F32T8/WM
1-25
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS
F32T8
transforming the power of light
1-24
ELECTRONIC
FLUORESCENT BALLASTS
Overall Dimensions Mounting Dimensions
Draw # L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
-A 9.50” 1.70” 1.18” 8.89” 1.69”
DIMENSIONS
Overall Dimensions Mounting Dimensions
Draw # L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
-A 9.50” 1.70” 1.18” 8.89” 1.69”
DIMENSIONS
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F32T8/WM - Two Lamp Applications
120 0.40 >.99 <10
49707 GE-232-MAX-L/Ultra 46 0.77 0/-18 1B -A
277 0.18 >.97 <17
120 0.45 53 >.99 <10
49772 GE-232-MAX-N/Ultra • 0.87 0/-18 1B -A
277 0.20 52 >.96 <15
2PAR-IS 120 0.42 >.99 <10
49708 GE-332-MAX-L/Ultra • 49 0.87 0/-18 1C -A
277 0.19 >.97 <17
120 0.46 >.99 <10
49773 GE-332-MAX-N/Ultra • 55 0.87 0/-18 1C -A
277 0.21 >.97 <15
120 0.50 >.99
47533 2 SER-PRS B232PUNVHP-A 60 0.88 <10 60/16 30 -A
277 0.21 >.98
FOR (2) F32T8/WM LAMPS
CUS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F32T8 - Two Lamp Applications
120 0.42 >.99 <10
49707 GE-232-MAX-L/Ultra 48 0.77 0/-18 1B -A
277 0.19 >.97 <17
120 0.47 54 >.99 <10
49772 GE-232-MAX-N/Ultra • 0.87 0/-18 1B -A
277 0.21 53 >.96 <15
120 0.84 74 >.99 <10
49775 GE-232-MAX-H/Ultra • 1.15 0/-18 1B -A
277 0.37 73 >.98 <13
120 0.45 >.99 <10
49708
2PAR-IS
GE-332-MAX-L/Ultra • 53 0.87 0/-18 1C -A
277 0.20 >.97 <16
120 0.49 >.99 <10
49773 GE-332-MAX-N/Ultra 58 0.87 0/-18 1C -A
277 0.22 >.97 <14
120 0.52 62 >.99
47533 2 SER-PRS B232PUNVHP-A 0.88 <10 0/-18 30 -A
277 0.22 60 >.98
FOR (2) F32T8 LAMPS
CUS
F32T8 & F32T8/WM
1-27
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS
F32T8 & F32T8/WM
transforming the power of light
1-26
ELECTRONIC
FLUORESCENT BALLASTS
DIMENSIONS
Overall Dimensions Mounting Dimension
Draw # L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
-A 9.50” 1.70” 1.18” 8.89” 1.69”
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F32T8/WM - Three Lamp Applications
120 0.60 69 >.99 <10
49708 GE-332-MAX-L/Ultra • 0.77 0/-18 1C -A
277 0.26 68 >.98 <13
120 0.66 78 >.99 <10
49773 GE-332-MAX-N/Ultra • 0.87 0/-18 1C -A
277 0.29 77 >.98 <13
3PAR-IS 120 0.89 106 >.99 <10
49776 GE-332-MAX-H/Ultra • 1.15 0/-18 1C -A
277 0.39 104 >.98 <13
80136 347 B332I347HP • 0.25 88 >.99 0.88 <10 0/-18 6 ST
120 0.73 87 >.99
41008 3 SER-PRS B332PUNVHP-A* 0.88 <10 0/-18 23 -A
277 0.32 85 >.95
* Preliminary performance data
FOR (3) F32T8/WM LAMPS
CUS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F32T8 - Four Lamp Applications
120 0.84 97 >.99 <10
49709 GE-432-MAX-L/Ultra • 0.77 0/-18 1D -A
277 0.37 96 >.98 <13
120 0.94 109 >.99 <10
49774 GE-432-MAX-N/Ultra • 0.87 0/-18 1D -A
277 0.40 107 >.98 <13
4PAR-IS
120 151
49777 GE-432-MAX-H/Ultra* • TBD TBD TBD TBD TBD TBD TBD
277 147
120 1.00 119 >.99
41009 4 SER-PRS B432PUNVHP-A 0.88 <10 0/-18 8 -A
277 0.42 115 >.95
FOR (4) F32T8 LAMPS
CUS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F32T8/WM - Four Lamp Applications
120 0.80 92 >.99 <10
49709 GE-432-MAX-L/Ultra • 0.77 0/-18 1D -A
277 0.36 91 >.98 <14
120 0.90 105 >.99 <10
49774 4 PAR-IS GE-432-MAX-N/Ultra • 0.87 0/-18 1D -A
277 0.39 103 >.98 <13
120 145
49777 GE-432-MAX-H/Ultra* • TBD TBD TBD TBD TBD TBD TBD
277 141
120 0.95 114 >.99
41009 4 SER-PRS B432PUNVHP-A* 0.88 <10 0/-18 8 -A
277 0.41 110 >.95
* Preliminary performance data
FOR (4) F32T8/WM LAMPS
CUS
Overall Dimensions Mounting Dimensions
Draw # L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
-A 9.50” 1.70” 1.18” 8.89” 1.69”
DIMENSIONS
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F32T8 - Three Lamp Applications
120 0.63 73 >.99 <10
49708 GE-332-MAX-L/Ultra • 0.77 0/-18 1C -A
277 0.27 72 >.98 <13
120 0.70 82 >.99 <10
49773 GE-332-MAX-N/Ultra • 0.87 0/-18 1C -A
277 0.30 80 >.98 <13
120 0.92 111 >.99 <10
49776 GE-332-MAX-H/Ultra • 1.15 0/-18 1C -A
277 0.40 109 >.98 <13
120 0.65 78 >.99 <13
49709 3 PAR-IS GE-432-MAX-L/Ultra • 0.87 0/-18 1D -A
277 0.29 77 >.97 <16
120 0.72 85
49774 GE-432-MAX-N/Ultra • >.99 0.87 <13 0/-18 1D -A
277 0.32 84
120
49777 GE-432-MAX-H/Ultra TBD TBD TBD TBD TBD TBD TBD TBD
277
80136 347 B332I347HP 0.25 88 >.99 0.88 <10 0/-18 6 ST
120 0.77 92 >.99
41008 3 SER-RS B332PUNVHP-A* 0.88 <10 0/-18 23 -A
277 0.34 90 >.95
120 0.77 92 >.99
41009 3 SER-PRS B432PUNVHP-A 0.93 <10 0/-18 23 -A
277 0.34 90 >.98
*Preliminary performance data
FOR (3) F32T8 LAMPS
CUS
T8 SLIMLINE F96T8
& F96T8/WM
1-29
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS
F40T8
transforming the power of light
1-28
ELECTRONIC
FLUORESCENT BALLASTS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F40T8 - One Lamp Applications
120 0.32 >.99 <10
49766 GE-159-MAX-N/Ultra • 38 0.94 0/-18 1A -A
277 0.15 >.95 <18
120 0.39 >.99 <10
49767 GE-259-MAX-N/Ultra • 46 0.94 0/-18 1B -A
277 0.18 >.95 <20
1IS
120
TBD GE-132-MAX-N/Ultra • TBD TBD TBD TBD TBD TBD 1A -A
277
F40T8 - Two Lamp Applications
120 0.66 77 <10
49767 GE-259-MAX-N/Ultra • >.97 0.94 0/-18 1B -A
277 0.29 76 <18
120
49773 2 PAR-IS GE-332-MAX-N/Ultra • • TBD TBD TBD TBD TBD TBD 1B -A
277
120
49776 GE-332-MAX-H/Ultra • • TBD TBD TBD TBD TBD TBD 1C -A
277
F40T8 - Three Lamp Applications
120
49774 GE-432-MAX-N/Ultra • TBD TBD TBD TBD TBD TBD 1C -A
3PAR-IS 277
120
49777 GE-432-MAX-H/Ultra • TBD TBD TBD TBD TBD TBD TBD ST
277
FOR (1), (2) & (3)
F40T8 LAMPS
CUS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F96T8 - One Lamp Applications
120 0.45 56 >.99 <10
49766 GE-159-MAX-N/Ultra • 0.87 0/-18 1A -A
277 0.21 55 >.95 <15
120 0.53 >.99 <10
49767 GE-259-MAX-N/Ultra • 62 0.87 0/-18 1B -A
277 0.24 >.97 <20
80142 120 B259I120HPL 0.51 60 >.98 0.92 <10 50/10 14 ST
80143
1IS
277 B259I277HPL 0.22 60 >.98 0.92 <10 50/10 14 ST
F96T8 - Two Lamp Applications
120 0.95 112 >.99 <10
49767 GE-259-MAX-N/Ultra • 0.87 0/-18 1B -A
277 0.41 110 >.98 <15
80148 120 B259I120RHH 1.30 150 >.98 1.18 <20 32/0 14 SL
80149 2 PAR-IS 277 B259I277RHH 0.56 150 >.98 1.18 <20 32/0 14 SL
80142 120 B259I120HPL 0.84 100 >.98 0.78 <10 50/10 14 ST
80143 277 B259I277HPL 0.36 100 >.98 0.78 <10 50/10 14 ST
FOR (1) AND (2) F96T8 LAMPS
CUS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F96T8/WM - One Lamp Applications
120 0.46 54 >.99 <10
49766 GE-159-MAX-N/Ultra • 0.87 0/-18 1A -A
1IS
277 0.20 53 >.95 <15
F96T8/WM - Two Lamp Applications
120 0.90 107 >.99 <10
49767 2 PAR-IS GE-259-MAX-N/Ultra • 0.87 0/-18 1B -A
277 0.39 105 >.98 <15
FOR (1) AND (2) F96T8/WM LAMPS
CUS
DIMENSIONS
Overall Dimensions Mounting Dimension
Draw # L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
-A 9.50” 1.70” 1.18” 8.89” 1.69”
-B 9.50” 1.50” 1.00” 8.89” 0.88”
DIMENSIONS
Overall Dimensions Mounting Dimension
Draw # L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
SL 11.75” 3.13” 1.78” 11.41” 2.00”
-A 9.50” 1.70” 1.18” 8.89” 1.69”
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
1-31
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS
transforming the power of light
1-30
ELECTRONIC
FLUORESCENT BALLASTS
T5
T5 ballasts incorporate poke
in connectors, for easy installation
DIMENSIONS
Overall Dimensions Mounting Dimensions
Draw # L W H M X
-C 14.25” 1.18” 1.00” 13.75”
-D 16.88” 1.18” 1.00” 16.20”
-C, -D
T8HO
DIMENSIONS
Overall Dimensions Mounting Dimensions
Draw # L W H M X
SL 11.75” 3.13” 1.78” 11.41” 2.00”
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F48T8HO - One Lamp Applications
80286 1IS
120 B286I120RH 0.47 48 > .90 1.00 < 30 -20/-29 3 SL
80287 277 B286I277RH 0.20 47 > .90 1.00 < 30 -20/-29 3 SL
F60T8HO - One Lamp Applications
80286 1IS
120 B286I120RH 0.56 60 > .90 0.99 < 30 -20/-29 3 SL
80287 277 B286I277RH 0.23 57 > .90 0.98 < 30 -20/-29 3 SL
F72T8HO - One Lamp Applications
80286 1IS
120 B286I120RH 0.64 71 > .90 0.98 < 30 -20/-29 3 SL
80287 277 B286I277RH 0.26 67 > .90 0.98 < 30 -20/-29 3 SL
F96T8HO - One Lamp Applications
80286 1IS
120 B286I120RH 0.79 92 > .90 0.96 < 25 -20/-29 3 SL
80287 277 B286I277RH 0.32 87 > .90 0.93 < 25 -20/-29 3 SL
F48T8HO - Two Lamp Applications
80286 2PAR-IS 120 B286I120RH 0.70 80 > .95 0.85 < 25 -20/-29 3 SL
80287 277 B286I277RH 0.30 77 > .90 0.84 < 25 -20/-29 3 SL
F60T8HO - Two Lamp Applications
80286 2PAR-IS 120 B286I120RH 0.85 99 > .95 0.85 < 20 -20/-29 3 SL
80287 277 B286I277RH 0.36 96 > .95 0.84 < 20 -20/-29 3 SL
F72T8HO - Two Lamp Applications
80286 2PAR-IS 120 B286I120RH 1.00 117 > .95 0.85 < 20 -20/-29 3 SL
80287 277 B286I277RH 0.42 114 > .95 0.84 < 20 -20/-29 3 SL
F96T8HO - Two Lamp Applications
80286 2PAR-IS 120 B286I120RH 1.30 151 > .95 0.81 < 20 -20/-29 3 SL
80287 277 B286I277RH 0.53 144 > .95 0.81 < 20 -20/-29 3 SL
FOR (1) & (2) F48T8HO, F60T8HO,
F72T8HO & F96T8HO LAMPS
CUS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F14T5 - One Lamp Applications
120 0.15 >.98 <10
47536 1 PRS B228PUNV-C 18 1.05 0/-18 4a -C
277 0.07 >.90 <15
F14T5 - Two Lamp Applications
120 0.28 >.98
47536 2 SER-PRS B228PUNV-C 34 1.00 <10 0/-18 4a -C
277 0.13 >.95
F21T5 - One Lamp Applications
120 0.21 >.98 <10
47536 1 PRS B228PUNV-C 25 1.03 0/-18 4a -C
277 0.10 >.95 <15
F21T5 - Two Lamp Applications
120 0.41 49
47536 2 SER-PRS B228PUNV-C >.98 1.00 <10 0/-18 4a -C
277 0.18 48
F28T5 - One Lamp Applications
120 0.28 >.98
47536 1 PRS B228PUNV-C 33 1.00 <10 0/-18 4a -C
277 0.12 >.95
F28T5 - Two Lamp Application
120 0.55 66
47536 2 SER-PRS B228PUNV-C >.98 1.00 <10 0/-18 4a -C
277 0.23 64
F35T5 - One Lamp Applications
120 0.34 >.98
47536 1 PRS B228PUNV-C 40 1.00 <10 0/-18 4a -C
277 0.15 >.95
F35T5 - Two Lamp Applications
120 0.67 81
47536 2 SER-PRS B228PUNV-C >.98 1.00 <10 0/-18 4a -C
277 0.28 78
T5 FOR F14, F21,
F28 & F35T5 LAMPS
CUS
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
1-33
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS
transforming the power of light
1-32
ELECTRONIC
FLUORESCENT BALLASTS
F25T12
T5HO & T10
Overall Dimensions Mounting Dimensions
Draw
#L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
-C 14.25” 1.18” 1.00” 13.75”
-D 16.88” 1.18” 1.00” 16.20”
DIMENSIONS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F24T5HO - One Lamp Applications
120 0.23 >.98
47534 B224PUNV-C 28 1.06 <10 0/-18 4b -C
277 0.10 >.95
120 0.27 >.98
47540
1PRS
B239PUNV-D 32 1.25 <10 0/-18 4b -D
277 0.13 >.90
F24T5HO - Two Lamp Applications
120 0.45 53
47534 B224PUNV-C >.98 1.00 <10 0/-18 4b -C
277 0.19 52
120 0.51 >.98
47540
2SER-PRS
B239PUNV-D 59 1.15 <10 0/-18 4b -D
277 0.22 >.95
F39T5HO - One Lamp Applications
120 0.34 41
47534 B224PUNV-C >.98 0.95 <10 0/-18 4b -C
277 0.15 40
120 0.39 >.98
47540
1PRS
B239PUNV-D 47 1.10 <10 0/-18 4b -D
277 0.18 >.95
F39T5HO - Two Lamp Applications
120 0.75 89
47540 2 SER-PRS B239PUNV-D >.98 1.00 <10 0/-18 4b -D
277 0.32 88
F54T5HO- One Lamp Applications
120 0.54 >.98
47542 1 PRS B254PUNV-D 64 1.10 <10 0/-18 4b -D
277 0.24 >.95
F54T5HO- Two Lamp Application
120 1.03 121
47542 2 SER-PRS B254PUNV-D >.98 1.00 <10 0/-18 4b -D
277 0.43 117
T5HO FOR F24, F39,
F28 & F54 T5HO LAMPS
CUS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F40T10 - One Lamp Applications
80152 120 B140R120HP 0.34 39 > .98 0.89 < 10 50/10 2 ST
80153 1RS
277 B140R277HP 0.15 39 > .98 0.89 < 10 50/10 2 ST
80154 120 B240R120HP 0.44 48 > .98 1.03 < 10 50/10 4 ST
80155 277 B240R277HP 0.19 48 > .98 1.03 < 10 50/10 4 ST
F40T10 - Two Lamp Applications
80154 2PAR-RS 120 B240R120HP 0.67 80 > .98 0.90 < 10 50/10 4 ST
80155 277 B240R277HP 0.29 80 > .98 0.90 < 10 50/10 4 ST
F40T10 - Three Lamp Applications
80156 3PAR-RS 120 B340R120HP 0.98 116 > .98 0.90 < 10 50/10 5 ST
80157 277 B340R277HP 0.43 116 > .98 0.90 < 10 50/10 5 ST
FOR F40T10 LAMPS
CUS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F25T12 - Two Lamp Applications
120 0.36 >.99 <10
49707 GE-232-MAX-L/Ultra • 42 TBD 0/-18 1B -A
277 0.16 >.96 <19
120 0.41 >.99 <10
49772
2PAR-IS
GE-232-MAX-N/Ultra 48 TBD 0/-18 1B -A
277 0.18 >.97 <16
F25T12 - Three Lamp Applications
120 0.53 >.99 <10
49708 GE-332-MAX-L/Ultra 63 TBD 0/-18 1C -A
277 0.24 >.97 <13
120 0.61 72 >.99 <10
49773 3PAR-IS GE-332-MAX-N/Ultra TBD 0/-18 1C -A
277 0.27 71 >.98 <13
80136 347 B332I347HP 0.21 71 >.99 0.79 <10 0/-18 6 ST
F25T12 - Four Lamp Applications
120 0.71 84 >.99 <10
49709 GE-432-MAX-L/Ultra TBD 0/-18 1D -A
277 0.31 83 >.97 <15
120 0.81 96 >.99 <10
49774 4 PAR-IS GE-432-MAX-N/Ultra TBD 0/-18 1D -A
277 0.35 95 >.98 <13
FOR (2), (3) & (4)
F25T12 (ANSI ONLY) LAMPS
CUS
-C, -D
Overall Dimensions Mounting Dimensions
Draw # L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
-A 9.50” 1.70” 1.18” 8.89” 1.69”
DIMENSIONS
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
F40T12 & F40T12/WM
1-35
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS
F30T12 & F30T12/WM
transforming the power of light
1-34
ELECTRONIC
FLUORESCENT BALLASTS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F30T12 - One Lamp Applications
80152 120 B140R120HP 0.26 30 > .95 0.91 < 10 50/10 2 ST
80153 1RS
277 B140R277HP 0.11 30 > .95 0.91 < 10 50/10 2 ST
80154 120 B240R120HP 0.33 37 > .95 1.05 < 10 50/10 4 ST
80155 277 B240R277HP 0.14 37 > .95 1.05 < 10 50/10 4 ST
F30T12 - Two Lamp Applications
87049 120 B240R120RH 0.51 59 > .95 0.92 < 20 50/10 4 ST
80154 2 PAR-RS 120 B240R120HP 0.50 60 > .95 0.92 < 10 50/10 4 ST
80155 277 B240R277HP 0.22 60 > .95 0.92 < 10 50/10 4 ST
F30T12 - Three Lamp Applications
80156 3PAR-RS 120 B340R120HP 0.75 90 > .98 0.91 < 10 50/10 5 ST
80157 227 B340R277HP 0.33 90 >.98 0.91 <10 50/10 5 ST
FOR (1), (2) & (3) F30T12 LAMPS
CUS
FOR (1), (2) & (3) F30T12/WM LAMPS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F30T12/WM - One Lamp Applications
80152 120 B140R120HP 0.24 27 > .97 0.86 < 10 60/16 2 ST
80153 1RS
277 B140R277HP 0.10 27 > .97 0.86 < 10 60/16 2 ST
80154 120 B240R120HP 0.30 33 > .95 1.00 < 10 60/16 4 ST
80155 277 B240R277HP 0.13 33 > .95 1.00 < 10 60/16 4 ST
F30T12/WM - Two Lamp Applications
80153 2PAR-RS 120 B240R120HP 0.46 53 > .98 0.88 < 10 60/16 4 ST
80157 277 B240R277HP 0.20 53 > .98 0.88 < 10 60/16 4 ST
F30T12/WM - Three Lamp Applications
80156 3PAR-RS 120 B340R120HP 0.64 76 > .98 0.88 < 10 60/16 5 ST
80157 277 B340R277HP 0.28 76 > .98 0.88 < 10 60/16 5 ST
CUS
FOR (1), (2) & (3)
F40T12 LAMPS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F40T12 - One Lamp Applications
80152 120 B140R120HP 0.33 39 > .99 0.88 < 10 50/10 2 ST
80153 277 B140R277HP 0.14 39 > .99 0.88 < 10 50/10 2 ST
87219 1 RS 120 B240R120RH 0.41 46 > .90 1.09 < 20 50/10 4 ST
80154 120 B240R120HP 0.42 46 > .98 1.02 < 10 50/10 4 ST
80155 277 B240R277HP 0.18 46 > .98 1.02 < 10 50/10 4 ST
F40T12 - Two Lamp Applications
87219 120 B240R120RH 0.62 73 > .98 0.89 < 20 50/10 4 ST
80154 120 B240R120HP 0.65 75 > .99 0.88 < 10 50/10 4 ST
80155 2 PAR-RS 277 B240R277HP 0.28 74 > .99 0.90 < 10 50/10 4 ST
80156 120 B340R120HP 0.70 84 > .98 1.04 < 10 50/10 5 ST
80157 277 B340R277HP 0.31 84 > .98 1.04 < 10 50/10 5 ST
F40T12 - Three Lamp Applications
80156 3PAR-RS 120 B340R120HP 0.94 113 > .99 0.88 < 10 50/10 5 ST
80157 277 B340R277HP 0.41 113 > .99 0.88 < 10 50/10 5 ST
CUS
FOR (1), (2) & (3)
F40T12/WM LAMPS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F40T12/WM - One Lamp Applications
80152 120 B140R120HP 0.28 33 > .98 0.86 < 10 60/16 2 ST
80153 277 B140R277HP 0.12 33 > .98 0.86 < 10 60/16 2 ST
87219 1 RS 120 B240R120RH 0.36 39 > .89 1.10 < 20 60/16 4 ST
80154 120 B240R120HP 0.35 39 > .98 0.97 < 10 60/16 4 ST
80155 277 B240R277HP 0.15 39 > .98 0.97 < 10 60/16 4 ST
F40T12/WM - Two Lamp Applications
87219 120 B240R120RH 0.53 62 > .95 0.89 < 20 60/16 4 ST
80154 2 PAR-RS 120 B240R120HP 0.54 64 > .99 0.86 < 10 60/16 4 ST
80155 277 B240R277HP 0.23 64 > .99 0.86 < 10 60/16 4 ST
FF40T12/WM - Three Lamp Applications
80156 3PAR-RS 120 B340R120HP 0.78 93 > .99 0.86 < 10 60/16 5 ST
80157 277 B340R277HP 0.34 93 > .99 0.86 < 10 60/16 5 ST
CUS
Overall Dimensions Mounting Dimensions
Draw
#L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
DIMENSIONS
Overall Dimensions Mounting Dimensions
Draw
#L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
DIMENSIONS
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
1-37
For more information, visit www.gelighting.com
ELECTRONIC
FLUORESCENT BALLASTS
T12 & T12/WM
transforming the power of light
1-36
ELECTRONIC
FLUORESCENT BALLASTS
T12 SLIMLINE & T12
HIGH OUTPUT
DIMENSIONS
Overall Dimensions Mounting Dimensions
Draw
#L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
SL 11.75” 3.13” 1.78” 11.41” 2.00”
FOR F48T12 LAMPS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F48T12 - One Lamp Applications
80160 1IS
120 B260I120HP 0.39 47 > .95 1.08 < 10 0/-18 14 SL
80161 277 B260I277HP 0.18 47 > .95 1.08 < 10 0/-18 14 SL
F48T12 - Two Lamp Applications
80158 120 B260I120RH 0.68 76 > .95 0.92 < 25 0/-18 14 SL
80159 2PAR-IS 277 B260I277RH 0.29 76 > .95 0.92 < 25 0/-18 14 SL
80160 120 B260I120HP 0.61 74 > .98 0.91 < 10 0/-18 14 SL
80161 277 B260I277HP 0.27 74 > .98 0.91 < 10 0/-18 14 SL
CUS
FOR F48T12/WM LAMPS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F48T12/WM - One Lamp Applications
80160 1IS
120 B260I120HP 0.36 42 > .95 1.08 < 15 60/16 14 SL
80161 277 B260I277HP 0.16 42 > .95 1.08 < 15 60/16 14 SL
F48T12/WM - Two Lamp Applications
80158 120 B260I120RH 0.60 64 > .95 0.92 < 25 60/16 14 SL
80159 2PAR-IS 277 B260I277RH 0.25 64 > .95 0.92 < 25 60/16 14 SL
80160 120 B260I120HP 0.57 66 > .95 0.93 < 10 60/16 14 SL
81161 277 B260I277HP 0.25 66 > .95 0.93 < 10 60/16 14 SL
CUS
FOR F72T12 LAMPS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F72T12 - One Lamp Applications
80158 120 B260I120RH 0.60 66 > .90 1.04 < 25 0/-18 14 SL
80159 1IS
277 B260I277RH 0.25 66 > .90 1.04 < 25 0/-18 14 SL
80160 120 B260I120HP 0.55 67 > .95 1.06 < 10 0/-18 14 SL
80161 277 B260I277HP 0.25 67 > .95 1.06 < 10 0/-18 14 SL
F72T12 - Two Lamp Applications
80158 120 B260I120RH 0.92 107 > .95 0.90 < 20 0/-18 14 SL
80159 2PAR-IS 277 B260I277RH 0.39 107 > .95 0.90 < 20 0/-18 14 SL
80160 120 B260I120HP 0.90 107 > .99 0.91 < 10 0/-18 14 SL
80161 277 B260I277HP 0.39 107 > .99 0.91 < 10 0/-18 14 SL
CUS
FOR F96T12 LAMPS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F96T12 - One Lamp Applications
80158 120 B260I120RH 0.73 83 > .95 1.02 < 25 0/-18 14 SL
80159 1IS
277 B260I277RH 0.31 83 > .95 1.02 < 25 0/-18 14 SL
80160 120 B260I120HP 0.70 84 > .98 1.05 < 10 0/-18 14 SL
80161 277 B260I277HP 0.31 84 > .98 1.05 < 10 0/-18 14 SL
F96T12 - Two Lamp Applications
80158 120 B260I120RH 1.16 133 > .95 0.86 < 20 0/-18 14 SL
80159 2PAR-IS 277 B260I277RH 0.50 133 > .95 0.86 < 20 0/-18 14 SL
80160 120 B260I120HP 1.16 137 > .99 0.88 < 10 0/-18 14 SL
80161 277 B260I277HP 0.50 137 > .99 0.88 < 10 0/-18 14 SL
CUS
FOR F96T12/WM LAMPS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F96T12/WM - One Lamp Applications
80158 120 B260I120RH 0.60 66 > .90 1.05 < 25 60/16 14 SL
80159 1IS
277 B260I277RH 0.26 66 > .90 1.05 < 25 60/16 14 SL
80160 120 B260I120HP 0.59 70 > .98 1.05 < 10 60/16 14 SL
80161 277 B260I277HP 0.26 70 > .98 1.03 < 10 60/16 14 SL
F96T12/WM - Two Lamp Applications
80158 120 B260I120RH 0.93 107 > .95 0.88 < 20 60/16 14 SL
80159 2PAR-IS 277 B260I277RH 0.40 107 > .95 0.88 < 20 60/16 14 SL
80160 120 B260I120HP 0.96 112 > .99 0.88 < 10 60/16 14 SL
80161 277 B260I277HP 0.40 112 > .99 0.88 < 10 60/16 14 SL
CUS
FOR T12 HIGH OUTPUT LAMPS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F72T12HO - Two Lamp Applications
80162 2SER-RS 120 B295SR120HP 1.40 169 > .99 0.95 < 10 -20/-29 4 SL
80163 277 B295SR277HP 0.61 169 > .99 0.95 < 10 -20/-29 4 SL
F73T12/BL/HO - Two Lamp Applications
80664 2 SER-RS 120 493B2 1.60 180 > .90 1.00 < 25 50/10 4 ST
F84T12HO - Two Lamp Applications
80162 2SER-RS 120 B295SR120HP 1.60 185 > .99 0.89 < 10 - 20/-29 4 SL
80163 277 B295SR277HP 0.69 185 > .99 0.91 < 10 - 20/-29 4 SL
F96T12HO - Two Lamp Applications
80162 2SER-RS 120 B295SR120HP 1.77 208 > .99 0.90 < 10 - 20/-29 4 SL
80163 277 B295SR277HP 0.76 208 > .99 0.90 < 10 - 20/-29 4 SL
CUS
FOR T12HO/WM HIGH OUTPUT LAMPS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC HL (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F96T12HO/WM - Two Lamp Applications
80162 2SER-RS 120 B295SR120HP 1.47 174 > .99 0.88 < 10 60/16 4 SL
80163 277 B295SR277HP 0.63 174 > .99 0.88 < 10 60/16 4 SL
CUS
DIMENSIONS
Overall Dimensions Mounting Dimensions
Draw # L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
SL 11.75” 3.13” 1.78” 11.41” 2.00”
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
1-39
For more information, visit www.gelighting.com
WIRING DIAGRAMS
WIRING DIAGRAMS
transforming the power of light
1-38
ELECTRONIC
FLUORESCENT BALLASTS
Line White
Black Blue
Blue
Blue
Red
BALLAST
LAMP
LAMP
LAMP
WIRING DIAGRAMS WIRING DIAGRAMS
DIAGRAM 14 DIAGRAM 30
DIAGRAM 23
DIAGRAM 1A
DIAGRAM 1 DIAGRAM 1B
DIAGRAM 1C DIAGRAM 1D DIAGRAM 2
DIAGRAM 3 DIAGRAM 4
DIAGRAM 4A
DIAGRAM 4B
DIAGRAM 5 DIAGRAM 6
DIAGRAM 8
White
Black
Line
Yellow Red
Red
Blue
Blue
Yellow BALLAST
LAMP
LAMP
LAMP
LAMP
DIAGRAM 7
DIAGRAM 7A DIAGRAM 13
ELECTRONIC
FLUORESCENT BALLASTS
1-41
For more information, visit www.gelighting.com
transforming the power of light
1-40
ELECTRONIC BALLASTS
DIMMING APPLICATION
& OPERATING INFO.
APPLICATION AND OPERATING INFORMATION
Dimming ballasts follow the same guidelines
as electronic ballasts in regard to the application
and operating information. In addition to the sec-
tion for electronic ballasts, the following applies
specifically to dimming electronic ballasts. See
pages 1-13 and 1-14 for electronic ballast applica-
tion and operating information.
V5 dimming ballasts are controlled by using
10-0vDC. Care should be taken to ensure that the
line voltage (AC) wires are not connected to the
low voltage DC wires. Electronic dimming ballasts
have a protection circuit that will sense if the bal-
last has been connected in this manner and not
harm the ballast or the installer. If connected in
this mode, the lamps will dim to the 30% level.
New Lamp Installation
When new lamps are installed, they must
operate at a full bright level for a minimum of 100
hours prior to dimming. Failure to do this will
effect lamp life and cause the lamps to not dim
properly. Consult your lamp manufacturer for fur-
ther lamp information.
Light Level Switching Installation Note
The two power leads for the light level switch-
ing ballasts must be connected to the same power
circuit. The leads should connect to separate
switches or relays for control of the light level
switching operation. Connection of the input
leads to separate power circuits can damage the
ballasts and cause electrical system problem.
Note:
Do not connect any other ballast to the load
side of the switches controlling the switched
dimming ballast.
Compatible Dimming Controls
For a listing of compatible controls for the V5
dimming ballasts, please see page1-45 in this
catalog.
Fusing
Class P ballasts do not require fusing. Fusing
can be used when a single circuit has a large num-
ber of fixtures/ballasts. For a comprehensive list of
appropriate fuses, contact your GE representative.
SAFETY
ELECTRONIC BALLASTS
DIMMING
PRODUCT OVERVIEW
The effective dimming of fluorescent lights delivers
a wide range of benefits: greater control of work-
space lighting, ability to create a mood, energy
savings, and more. Our electronic T8 fluorescent
dimming products help you save as much as 30%
on energy bills—and they meet today’s toughest
specification requirements, including ASHRAE 90.1
and California Title 24.
GE offers three options for variable lighting
control: continuous dimming (100% to 5%) and
two forms of light level switching (either 100/50%
or 100/60/30%).
Dimming ballasts from GE are designed to
ensure optimum lamp performance. Their Lamp
Current Crest Factors are well below the maximum
1.7 ANSI standard — and they start the lamps
according to ANSI recommendations throughout
the entire dimming range. Both of these important
design parameters ensure optimum lamp perform-
ance. In addition, our dimming ballasts actually
increase cathode heating when dimming to
maintain the cathode’s proper temperature, which
enhances lamp life and performance stability.
Continuous Dimming (V5)
• 1, 2 & 3 lamp models with full range
dimming (100% to 5%)
• Designed for optimal lamp performance
— Cathode voltage increases as lamps dim
— Positive starting at all dimming levels
— No lamp dropout
— No flicker at all dimming levels
• Line voltage control circuit protection
— Miswiring of control leads will not damage
the ballast
• Compatible with all 0 to 10 Volt DC controls
and photocells
• Maximum energy savings versus comparable
ballasts on the market
• THD <10% throughout the entire dimming
range
• 120, 277 and 347 Volt models available
Light Level Switching (S30 & S50)
• 1, 2, & 3 lamp models for 120 & 277 Volt
• Switches to preset light levels, keeping all
lamps illuminated
• Eliminates the dark spots associated with
inboard/outboard
• Connects with two line voltage power leads
— Wires the same as an inboard/outboard
fixture
— No special controls required; uses two wall
switches
• Meets all ASHRAE 90.1 and California Title 24
requirements for lighting control
• THD <10%
• Lower installed costs; less wiring and
equipment required
DIMMING PRODUCT OVERVIEW
GE dimming ballasts help you save as much as 30%
on energy bills.
GE Light Level Switching for ultimate control.
1-43
For more information, visit www.gelighting.com
transforming the power of light
1-42
DIMMING CONTROLS
CROSS REFERENCE
ELECTRONIC BALLASTS
CONTROLS CROSS REFERENCE
Data Subject to Change Without Notice
Company Name Slide Dimmer Photo Sensor
& Phone or Modules 10-0 Volts
Electronics Diversified MX Dimming System
800-547-2690 Versa-Pak Dimming System
Prolight Dimming System
Honeywell EL7315A1019
800-345-6770 EL7315A1009
use with EL7305A1010
Hunt Dimming
970-484-9048 PS-010-xxx
Leviton Centura Centura
800-824-3005 Illuma Tech IP7 Photocell: 0DC0P
DPSPE-212
Lightolier Controls Sunrise Slider
800-526-2731 Momentum Slider
Vega Slider
LEQ BC
Lithonia Controls LEQ LVBC
800-533-2719 SLD LVBC LEQ DPC
SQ1DC
Novitas 01-PCx
310-568-9600
PLC Multipoint EDSAB
425-353-7552 RCD
Prescolite Controls Element
800-DIMMERS EW-EF
PA7
Sensor Switch
800-727-7483 CM-ALC
Thomas Industries
601-842-7212 DHC-LSD
UNENCO Daylight Tracker
800-227-0452 DT-D
Watt Stopper LS-4 LCD-1xx
800-879-8585 use with LCD-101 and LCD-103 LS-xxx
Compatible B332SRxxxV5 (xxx = 120 or 277)
Ballasts B232SRxxxV5 (xxx = 120, 277 or 347)
B132RxxxV5 (xxx = 120, 277 or 347
ELECTRONIC BALLASTS
DIMMING
SPECIFICATIONS
TYPICAL SPECIFICATIONS
FOR DIMMING BALLASTS
Continuous Dimming & Light Level
Switching
1. Ballasts shall operate from 60 Hz input source
of 120, 277 Volts, and sustained variations of
±10% (Voltage & Frequency) with no damage
to the ballasts.
2. Ballasts shall be a high frequency electronic
type, and operate lamps at a frequency above
20 kHz.
3. Lamp Current Crest Factor (ratio of peak to
RMS current) shall be 1.7 or less in accordance
with lamp manufacturer recommendation and
ANSI C82.11-1993.
4. Ballasts shall tolerate operation in ambient
temperatures up to 105°F (40°C) without
damage.
5. Ballasts shall comply with FCC Part 18 Non-
Consumer Equipment for EMI (power line
conducted) and RFI (Radiated).
6. Ballasts shall provide transient immunity as
recommended by ANSI C62.41-1991.
7. Ballasts shall operate lamps with no visible
flicker (<3% flicker index).
8. Ballasts shall tolerate sustained open circuit
and short circuit output conditions without
damage.
9. Ballasts shall be Underwriters Laboratory (UL
935) listed, Class P, Type 1 Outdoor, and CSA
certified where applicable.
10. Ballast shall have a Ballast Factor greater than
.85 per ANSI C82.11-1993, in the 100% light
position.
11. Input current Total Harmonic Distortion shall
not exceed 10% for the primary lamp.
12. Ballasts shall have a Power Factor greater than
.98 for primary lamp.
13. The ballasts shall not have any PCBs.
14. The manufacturer shall provide written warran-
ty against defects in material or workmanship,
including replacement, for five years from date
of manufacture.
15. Ballast shall be manufactured in an ISO 9001
Certified Facility.
16. Ballasts shall provide rapid starting sequence
consistent with ANSI standard C82.11-1993.
17. GE model ___________ (or approved equal).
Continuous Dimming:
From 100% to 5% (V5 Ballast)
Ballast 10-0 Volt (DC) control leads shall have
safety/protection circuitry to protect the ballast
against improper wiring of line voltage (AC) to
control leads (DC).
In the event of improper wiring, the ballast will
operate with no harm to the ballast or user.
The ballast will dim to a 30% light level.
•All lamps must remain on at low light levels
(No Lamp Dropout).
Light Level Dimming:
From 100% to 60% to 30% or
100% to 50% (S30/S50 Ballasts)
Ballast(s) must be operable with two standard
wall switches or relays.
Both switches must be wired on same phase
of circuit.
Ballast(s) must be compatible with Power Line
Carrier (PLC) Systems.
Ballast must provide equal lamp current to
each lamp at all settings.
1-45
For more information, visit www.gelighting.com
transforming the power of light
1-44
ELECTRONIC BALLASTS
DIMMING F32T8
DIMENSIONS
Overall Dimensions Mounting Dimensions
Draw
#L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
-ZZ 16.40” 2.40” 1.50” 15.88” 1.69”
DIMMING BALLASTS FOR
(2), (3) & (4) F32T8 LAMPS
DIMMING BALLASTS
FOR (1) F32T8 LAMPS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F32T8 - Two Lamp Applications
B232SR120S30 @ 100% 0.52 62 > .99 0.88 < 10 50/10 16 ST
80367 120 B232SR120S30 @ 60% 0.38 45 > .95 0.58 < 10 50/10 16 ST
B232SR120S30 @ 30% 0.24 28 > .95 0.27 < 10 50/10 16 ST
B232SR277S30 @ 100% 0.23 62 > .99 0.88 < 10 50/10 16 ST
80368 277 B232SR277S30 @ 60% 0.17 45 > .95 0.58 < 10 50/10 16 ST
B232SR277S30 @ 30% 0.11 28 > .95 0.27 < 10 50/10 16 ST
80361 2 SER-RS 120 B232SR120S50 @ 100% 0.52 62 > .99 0.88 < 10 50/10 16 ST
B232SR120S50 @ 50% 0.31 37 > .95 0.48 < 10 50/10 16 ST
80362 277 B232SR277S50 @ 100% 0.23 62 > .99 0.88 < 10 50/10 16 ST
B232SR277S50 @ 50% 0.14 37 > .95 0.48 < 10 50/10 16 ST
80355 120 B232SR120V5 @ 100% 0.52 62 > .99 0.88 < 10 50/10 19 ST
B232SR120V5 @ 5% 0.12 13 > .90 0.05 < 10 50/10 19 ST
80356 277 B232SR277V5 @ 100% 0.23 62 > .99 0.88 < 10 50/10 19 ST
B232SR277V5 @ 5% 0.05 13 > .90 0.05 < 15 50/10 19 ST
86448 347 B232SR347V5 @ 100% 0.18 62 > .99 0.88 < 10 50/10 19 ST
B232SR347V5 @ 5% 0.04 13 > .90 0.05 < 15 50/10 19 ST
80362 277 B232SR277S50 @ 100% 0.23 62 >.99 0.88 <10 50/10 16 ST
B232SR277S50 @ 50% 0.14 37 >.90 0.48 <10 50/10 19 ST
F32T8 - Three Lamp Applications
B332SR120S30 @ 100% 0.78 93 > .99 0.88 < 10 50/10 17 ST
80369 120 B332SR120S30 @ 60% 0.61 69 > .95 0.60 < 10 50/10 17 ST
B332SR120S30 @ 30% 0.40 43 > .95 0.30 < 10 50/10 17 ST
B332SR277S30 @ 100% 0.34 94 > .99 0.88 < 10 50/10 17 ST
80370 277 B332SR277S30 @ 60% 0.26 69 > .95 0.60 < 10 50/10 17 ST
B332SR277S30 @ 30% 0.16 43 > .95 0.30 < 10 50/10 17 ST
80363 3 SER-RS 120 B332SR120S50 @ 100% 0.78 93 > .99 0.88 < 10 50/10 17 ST
B332SR120S50 @ 50% 0.50 57 > .95 0.48 < 10 50/10 17 ST
80364 277 B332SR277S50 @ 100% 0.34 93 > .99 0.88 < 10 50/10 17 ST
B332SR277S50 @ 50% 0.22 57 > .95 0.48 < 10 50/10 17 ST
80357 120 B332SR120V5 @ 100% 0.77 92 > .99 0.88 < 10 50/10 20 ST
B332SR120V5 @ 5% 0.17 20 > .90 0.05 < 10 50/10 20 ST
80358 277 B332SR277V5 @ 100% 0.33 92 > .99 0.88 < 10 50/10 20 ST
B332SR277V5 @ 5% 0.07 20 > .90 0.05 < 15 50/10 20 ST
F32T8 - Four Lamp Applications
????? 4 SER-RS 277 B432SR277V5 @ 100% 0.42 112 > .99 0.88 < 10 50/10 26 -ZZ
B432SR277V5 @ 5% 0.11 27 > .90 0.05 < 15 50/10 26 -ZZ
CUS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F32T8 - One Lamp Applications
B132R120S30 @ 100% 0.27 32 > .99 0.89 < 10 50/10 15 ST
80365 120 B132R120S30 @ 60% 0.19 23 > .99 0.60 < 10 50/10 15 ST
B132R120S30 @ 30% 0.12 14 > .98 0.28 < 10 50/10 15 ST
B132R277S30 @ 100% 0.13 33 > .99 0.89 < 10 50/10 15 ST
80366 277 B132R277S30 @ 60% 0.09 25 > .98 0.63 < 15 50/10 15 ST
B132R277S30 @ 30% 0.06 15 > .95 0.28 < 20 50/10 15 ST
80359 1 RS 120 B132R120S50 @ 100% 0.27 32 > .99 0.89 < 10 50/10 15 ST
B132R120S50 @ 50% 0.16 19 > .98 0.44 < 10 50/10 15 ST
80360 277 B132R277S50 @ 100% 0.13 36 > .99 0.89 < 10 50/10 15 ST
B132R277S50 @ 50% 0.07 19 > .95 0.45 < 20 50/10 15 ST
80353 120 B132R120V5 @ 100% 0.27 32 > .99 0.88 < 10 50/10 18 ST
B132R120V5 @ 5% 0.07 8 > .90 0.05 < 10 50/10 18 ST
80354 277 B132R277V5 @ 100% 0.12 32 > .99 0.88 < 10 50/10 18 ST
B132R277V5 @ 5% 0.03 8 > .90 0.05 < 15 50/10 18 ST
86446 347 B132R347V5 @ 100% 0.09 32 > .99 0.88 < 10 50/10 18 ST
B132R347V5 @ 5% 0.02 8 > .90 0.05 < 20 50/10 18 ST
CUS
ELECTRONIC BALLASTS
DIMMING
F25T8 & F32T8
DIMENSIONS
Overall Dimensions Mounting Dimensions
Draw
#L W H M X
ST 9.50” 2.40” 1.55” 8.89” 1.69”
DIMMING BALLASTS
FOR (1) & (2) F25T8 LAMPS
GE Lamp Certification Line Input Power Ballast Min. F/C
Product Code Starting Line Catalog UL Type Current Power Factor Factor THD Start Wiring
(C Pack) Qty. Method Volts Number CC (Amps) (Watts) (PF) (BF) % Temp Diag. Dim.
F25T8 - One Lamp Applications
B132R120S30 @ 100% 0.20 24 > .99 0.93 < 10 50/10 15 ST
80365 120 B132R120S30 @ 60% 0.16 19 > .99 0.62 < 10 50/10 15 ST
B132R120S30 @ 30% 0.10 12 > .98 0.29 < 15 50/10 15 ST
B132R277S30 @ 100% 0.10 27 > .98 0.91 < 10 50/10 15 ST
80366 277 B132R277S30 @ 60% 0.08 21 > .95 0.63 < 25 50/10 15 ST
B132R277S30 @ 30% 0.06 13 > .90 0.28 < 25 50/10 15 ST
80359 1 RS 120 B132R120S50 @ 100% 0.24 29 > .99 0.92 < 10 50/10 15 ST
B132R120S50 @ 50% 0.13 16 > .98 0.46 < 10 50/10 15 ST
80360 277 B132R277S50 @ 100% 0.10 27 > .98 0.91 < 10 50/10 15 ST
B132R277S50 @ 50% 0.06 17 > .95 0.47 < 20 50/10 15 ST
80353 120 B132R120V5 @ 100% 0.22 26 > .99 0.90 < 10 50/10 18 ST
B132R120V5 @ 5% 0.06 7 > .90 0.05 < 15 50/10 18 ST
80354 277 B132R277V5 @ 100% 0.10 26 > .99 0.90 < 10 50/10 18 ST
B132R277V5 @ 5% 0.03 7 > .90 0.05 < 20 50/10 18 ST
86446 347 B132R347V5 @ 100% 0.08 26 > .99 0.90 < 10 50/10 18 ST
B132R347V5 @ 5% 0.02 7 > .90 0.05 < 30 50/10 18 ST
F25T8 - Two Lamp Applications
80362 2 SER-RS 277 B232SR277S50 @ 100% 0.18 48 > .99 0.88 < 10 50/10 16 ST
B232SR277S50 @ 50% 0.11 29 > .95 0.45 < 20 50/10 16 ST
CUS
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
IS = Instant Start
PRS = Programmed Rapid Start
RS =Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
transforming the power of light
1-46
DIMMING WIRING DIAGRAMS
DIAGRAM 15 DIAGRAM 16 DIAGRAM 17
DIAGRAM 18 DIAGRAM 19 DIAGRAM 20
ELECTRONIC BALLASTS
DIMMING DIAGRAMS
2-1
For more information, visit www.gelighting.com
ELECTROMAGNETIC
FLUORESCENT BALLASTS
A WIDE PRODUCT LINE TO MEET ALL
YOUR NEEDS
Our comprehensive line of magnetic ballasts offers outstanding
performance and value. These energy-efficient ballasts are available
for a wide variety of applications.
GE's full spectrum of solutions includes ballasts for
T12/T10/T8 applications, plus Slimline, Circline, trigger-
start and preheat ballasts. We also make rugged
weatherproof ballasts...and models specifically
engineered for the fast growing export market.
GE has a comprehensive line of energy-efficient magnetic
ballasts for T12, T10 and T8 applications.
ELECTROMAGNETIC
FLOURESCENT
BALLASTS
2-3
For more information, visit www.gelighting.com
ELECROMAGNETIC
FLUORESCENT BALLASTS
transforming the power of light
2-2
ELECROMAGNETIC
FLUORESCENT BALLASTS
PRODUCT OVERVIEW PRODUCT OVERVIEW
Rapid Start
Ballasts
T12/10 Applications
Rapid Start Ballasts
These ballasts provide smooth starting to rapid start
lamps – reaching full brightness in about two seconds
without the use of starters. They have built-in filament
windings that energize the low-voltage cathodes in rapid
start lamps. Because electrodes are continuously heated,
less voltage is required to strike an arc through a rapid
start lamp than a slimline one.
Ballasts for T12/T10 Applications
GE offers a wide variety of T12 and T10 ballasts to
operate 1-3 rapid start lamps. This lamp/ballast system
provides smooth, virtually instant starting without the use
of starters (30-and 40-watt T12 models and 40-watt T10
models are available). Models for U-lamp applications are
also available. These “hybrid” type ballasts incorporate an
electronic switch which disconnects power to the lamp
cathodes after start-up, saving additional energy.
Ballasts for T8 Applications
GE‘s T8 product offering includes models for F17,
F25, F32 and F40 type T8 lamps. This product line fea-
tures OcTekelectromagnetic ballast models. These mod-
els are low initial cost energy efficient options for use
with F32T8, 4-foot rapid start lamps. These models are
available in several variations, including full, medium, low
light output and hybrid versions (OkTekPlus). These
models maximize energy savings and provide effective
choices when retrofitting 4-foot T12 fixtures.
T8 Applications
Rapid Start Dimming
Ballasts
Slimline Ballasts
Rapid Start Dimming Ballasts
Light levels produced by fluorescent lamps can be
adjusted by using rapid start dimming ballasts in
conjunction with proper control devices. These ballasts
are generally for one- and two-lamp operation of 40-
watt rapid start lamps – and they may also be used with
30-watt rapid start lamps. However, 30-watt lamps and
40-watt lamps should not be mixed on the same
dimming control. Different colors and brands of lamps,
or different ballast brands, also should not be mixed on
the same dimming control. All dimming ballasts are
recommended for use with phase controlled-type
dimming controls only and subject to the approval of the
dimming control manufacturer.
Slimline Ballasts
Our slimline models are designed for use with sin-
gle-pin slimline lamps. They do not require the use of
starters. These ballasts deliver a high-starting voltage to
the lamps, enabling an arc to strike through the tube
without preheating the lamp cathodes (which are
specially constructed to withstand the shock).
Preheat Ballast Export (50/60 Hz) Ballast
Circline Ballasts
These products are available in 430 mA rapid start
and preheat types, designed for use with circline
lamps. The operating characteristics are the same for
both circline and conventional lamps. All circline socket
wires are fully sleeved.
Trigger-Start Ballasts
These ballasts are designed for use with general
fluorescent lamps and do not require the use of
starters. They contain preheat windings which allow
regular lamp filaments to be heated in one second.
However, they require a higher open-circuit voltage
than rapid start ballasts.
Preheat Ballasts
These units are designed for use with general
fluorescent lamps and require the use of starters. These
ballasts deliver an open-circuit voltage high enough to
activate the starter to preheat lamp filaments to a
temperature approximately 1750°F. After a few sec-
onds, the starter opens the filament circuit. This pro-
vides an additional power surge to enable an electric
arc to strike through the lamp and ignite it. Lamp cur-
rent is then limited by the ballast to an operating level
proper for the lamp.
Weatherproof Ballasts
Ballasts designated as “weatherproof” are designed
to withstand direct exposure to rain and snow and are
Underwriters Laboratories, Inc.–approved for this pur-
pose. The weatherproof ballasts listed within the cata-
log are enclosed in a round extruded aluminum can
with the cover sealed be a double-rolled seam. It is
supplied with a detached aluminum mounting bracket
containing four keyholes and a stainless steel band with
a threaded fastener. The mounting bracket can be locat-
ed at any point on the cylinder portion of the ballast.
There is no junction box supplied with the ballast. A
standard 3/4", 14 N.P. thread nipple is provided at one
end of the ballast to allow for the selection of a weath-
ertight junction box most applicable to the particular
needs and local electrical code requirements.
Export (50/60 Hz) Ballasts
Our export product offering consists of a variety of
one- and two-lamp models for rapid start, preheat,
high output, slimline, and 1500 mA lamps. Included in
this product line are ballasts for 50 and 60 Hz applica-
tions, including 110, 120, 127, 220, 230, 240, and
277 Volts. Many of these models are available with
resetting thermal protection.
PRODUCT OVERVIEW
PRODUCT OVERVIEW
Electromagnetic and hybrid ballasts may be
remote mounted according to the table below:
2-5
ELECROMAGNETIC
FLUORESCENT BALLASTS
transforming the power of light
2-4
ELECROMAGNETIC
FLUORESCENT BALLASTS
APPLICATION AND OPERATING INFORMATION APPLICATION AND OPERATING INFORMATION
VOLTAGE RANGE
Minimum
110
205
220
255
315
450
570
Maximum
125
232
250
290
364
505
630
Nominal Voltage
120
220
240
277
347
480
600
Wire size 30-40 Watt
Rapid Start 800 mA - HO
1500 mA - VHO Instant Start
(Slimline)
Red/Blue
Leads
Yellow
Leads
Red/Blue
Leads
Yellow
Leads
#6
#8
#10
#12
#14
#16
#18
All Leads
544'
340'
214'
134'
84'
52'
30'
384'
240'
150'
94'
60'
36'
20'
272'
170'
107'
67'
42'
26'
21'
192'
120'
75'
47'
30'
18'
15'
544'
340'
214'
134'
84'
52'
30'
For more information, visit www.gelighting.com
APPLICATION
AND OPERATING
INFORMATION
APPLICATION
AND OPERATING
INFORMATION
SAFETY
NEC & UL Requirements
Ballast installation presents the possibility of
exposure to potentially hazardous voltages and
should be performed only by qualified personnel.
All installation, inspection, and maintenance
should be performed only with power to the
fixture turned off. Additionally, all fixtures and
ballasts must be installed and operated in compli-
ance with the National Electrical Code, Underwriters
Laboratories Inc. (UL) requirements, and all local
applicable codes and regulations.
Polarity
Polarity refers to the proper connection of bal-
last lead wires to line wires. To aid you in making a
correct installation, GE ballast leads are color-coded
for easy identification. The WHITE ballast lead is to
be connected to the neutral (grounded) and the
BLACK (or black with white tracer) lead always to
the phase (“hot”) line wire. Systems where neither
of the line wires are at ground potential require
specially designed ballasts. A change in polarity may
result in the voltage from the lead to the ground
exceeding UL-specified limits. In some types of bal-
lasts, a change in polarity may decrease voltage
from the lead to the ground, thereby impeding the
starting dependability of the ballast.
Grounding
Ballast cases and fixtures must always be
grounded. The ballast case may be grounded to the
fixture or otherwise grounded. It could be haz-
ardous to make contact with an ungrounded fixture
or ballast when in operation. Neglecting to properly
ground the ballast and fixture combination may also
result in failure of certain lamps to start or for unac-
ceptable levels of electromagnetic noise to be con-
ducted onto the power lines.
Operating Line Voltage Limits
To receive the full benefits of rated lamp output
and to prolong ballast life, it is essential that voltage
supplied to an installation be maintained within lim-
its prescribed for each circuit. These limits are listed
in the next column.
Subjecting a ballast to excessive voltage for an
extended period results in the deterioration of the
insulation. This insulation breakdown will cause early
ballast failure.
Low voltage has no damaging effect on the bal-
last. However, lamps may not start reliably, and early
lamp failure could result.
Internal Ballast Protection
Class P Classification – Since January 1, 1984, the
National Electrical Code requires that “where
Fluorescent fixtures are installed indoors, the ballast
shall have thermal protection integral within the bal-
last except for simple reactance ballasts.” This ruling
applies to replacement ballasts as well as to those
contained within new light fixtures.
In compliance with the National Electrical Code,
UL has established a Class P ballast classification for
fluorescent light fixtures indoors. A Class P ballast
must employ internal thermal protection limiting its
operating temperature.
GE UL-approved Class P ballasts comply with the
National Electrical Code requirement and are
equipped with an automatic resetting thermal protec-
tor, built-in and adjacent to the transformer coils. The
resetting thermal protector functions as a thermostat,
which will open and temporarily deactivate the bal-
last when it exceeds the permissible temperature. It
will reset when the ballast cools to a safe operating
temperature. The ballast will continue to cycle until
the cause of overheating is eliminated. If the ballast is
defective, it must be replaced. If the cause is external,
a Class P ballast will resume normal operation after
abnormal conditions are eliminated.
Fusing
Class P ballasts do not require fusing. Fusing can
be used when a single circuit has a large number of
fixtures/ballasts. For more information, contact your
GE Lighting representative or visit
www.gelighting.com.
PERFORMANCE
Lamp Connections
Electromagnetic fluorescent ballasts are designed
to generate voltages in excess of 300 Volts. It is
imperative that proper connection to good quality
sockets be assured in accordance with wiring dia-
grams throughout this catalog and on product labels.
Some applications may not require the use of all of
the ballast output leads. If any leads are not to be
connected, each should be individually capped and
insulated to at least 600 Volts.
Application Versatility
Many GE models are designed to allow for appli-
cations with different types or quantities of lamps.
Use of products other than noted is not covered by
UL Listing and/or CSA certification and cannot be
warranted.
Audible Noise (Sound)
Electrical equipment, including most fluorescent
lamp ballasts, produces some noise. Care must be
taken to select a ballast with the proper sound rating
for a particular lighting installation. Ballast sound will
be noticeable only when it exceeds the ambient
sound level.
Although no industry standards currently exist,
the generally accepted criteria for sound rating speci-
fications are as follows:
Remote Mounting
Excessive hot or cold temperatures, audible
noise requirements, or a desire to operate lamps
in more than one fixture with the same ballast
(master/slave), may make it desirable to mount the
ballast remotely. Care must be taken to allow for
ballast heat dissipation and proper grounding.
In any application, the wire used to extend
leads must be at least as large as the wire supplied
on the ballast (18 AWG) with an insulation rating
of 1000 VAC at 90°C. Lead lengths in excess of
those noted cause loading effects that can dra-
matically impact ballast performance and void the
warranty.
Operating Temperature
Most fluorescent ballasts and lamps are designed
to provide optimum performance at an ambient tem-
perature of 77°F. Three key performance attributes
can be impacted by the ambient (room) temperature
of the installation:
• Lamp Starting Dependability
Fluorescent lamps are inherently more difficult to
start at low temperatures. All ballasts have limi-
tations as to their ability to start lamps at low
ambient temperatures. In this catalog, the low
starting point for each lamp/ballast combination
appears in the column marked ”Minimum
Starting Temperature.“
• Light Output
Optimum light output from fluorescent lamps
is achieved when the lamp wall is at 100-
110°F. Any substantial excursion (either colder
or warmer) will result in a reduction in light
output.
• Ballast Life
A fluorescent lamp ballast, like any other elec-
trical device, generates heat during its normal
operation. Ballast temperatures should be kept
as low as possible. Maximum dissipation of
heat through fixture design and proper bal-
last installation will help. Although excessive
temperature may not cause the ballast to fail
immediately, it can shorten ballast life. To
assure maximum life, the ballast case temper-
ature should not exceed 90°C.
Location Average Ballast
Ambient Noise Recommendation
Typical Office < 30 decibels A
Noisy Office or Retail 31-36 decibels B
Factory, Outdoor > 36 decibels C
2-7
For more information, visit www.gelighting.com
ELECROMAGNETIC
FLUORESCENT BALLASTS
transforming the power of light
2-6
ELECROMAGNETIC
FLUORESCENT BALLASTS
APPLICATION AND OPERATING INFORMATION SPECIFICATIONS
Other ballasts can also be manufactured to meet
low-leakage requirements. Consult GE for complete
information regarding low-leakage ballasts.
TYPE 1 BALLASTS
All GE outdoor non-weatherproof magnetic
ballasts (except those for sign applications) are
designed to meet UL requirements for Type 1 use
(metal enclosure required for wet or damp locations).
BALLASTS FOR
GERMICIDAL LAMPS
GE manufactures ballasts to operate germicidal
lamps. When ordering, make sure the ANSI
designation of the germicidal lamp matches exactly
with the ballast's recommended application.
Several typically encountered germicidal lamps are
listed below along with the proper GE ballast for
their operation.
Contact GE Lighting for additional information
or applications not listed.
Lamps
Line
Voltage
@60Hz
Maximum
Leakage
To Ground
Catalog
Number
(2)F30T12/RS
120 20uA 86251
573-L-TC-P-IP
(1)F40T12/RS
120 30uA 86101
412-L-SLH-TC-P-IP
(2)F40T12/RS
120 30uA 86137
446-L-SLH-TC-P
(1)F40T12/RS
277 50uA 96158
458-L-SLH-TC-P-IP
(2)F40T12/RS
277 50uA 86123
443-L-SLH-TC-P
Germicidal
Lamp GE Ballast See Page
Number
(1)G15T8 200-H2 2-19 - 2-20
1. Ballasts shall be certified energy saving
magnetic type and operate lamps at a
frequency of 60 Hz.
2. Ballasts shall be specifically designed to
operate (Quantity & Type) lamps.
3. Ballasts shall operate from 60 Hz input
source of _______ Volts*, and tolerate
sustained variations of +5%-10% with
no damage to the ballasts.
4. Ballasts shall provide transient immunity as
recommended by ANSI C62.41-1991,
Location Category A1.
5. Ballasts shall provide starting sequence
consistent with ANSI standard C82.1.
6. Ballasts shall tolerate sustained open cir-
cuit and short circuit output conditions
with no damage to the ballasts.
7. Ballasts shall be:
• UL LISTED as Class P and for use in
indoor or Type 1 outdoor applications.
• CSA CERTIFIED where applicable
(120 and 347 Volt models).
8. Ballasts shall tolerate operation, in most
fixtures, at ambient temperatures up to
105°F (40°C). Ballast enclosure is limited
to 90°C maximum temperature.
9. Ballasts shall have a Power Factor greater
than .90.
10.Lamp Current Crest Factor (ratio of peak to
RMS current) shall be 1.7 or less in accordance
with lamp manufacturers recommendation
and ANSI C82.11-1993.
• 1.85 or less for instant start
Slimline (also per ANSI C82.1).
11.Ballasts shall have a Ballast Factor greater
than .925 per ANSI C82.11-1993.
• .95 or greater for HO and VHO
applications.
12.Input current Total Harmonic Distortion
shall not exceed .32 per ANSI C82.1.
13.Ballasts shall be fully encapsulated (potted)
to ensure maximum thermal and structural
integrity.
14.Manufacturer shall provide written war-
ranty against defects in material or work-
manship.
15.Manufacturer shall have been manufac-
turing electromagnetic ballasts for at
least twenty years.
16.Ballast shall be manufactured in North
America
17.GE model*______________ (or approved equal).
APPLICATION
AND OPERATING
INFORMATION
GE
Product
Code
SPECIFICATIONS
Operating Temperature, continued
Causes of ballast overheating:
• Incorrect primary voltage or frequency
• Incorrect size, type or number of lamps
• Failed lamp starter
• Incorrect wiring
• Poor heat dissipation due to surrounding
insulation
• Sealed (Vapor Tight) Fixtures - Unusual heat
build-up due to lack of ventilation in fixtures
may cause thermal (on/off) cycling of certain
ballasts. Consult GE for specific recommenda-
tions.
Recommendations:
• Selection of a proper ballast to match the
requirements of the lamp, fixture, voltage and
installation
• Mounting of ballast within the fixture with as
much surface contact as possible between the
ballast and metal portions of the fixture.
• The use of heat-conducting dissipators (radia-
tors), if necessary, which increases surface
contact between the ballast and fixture.
• If necessary, locate the ballast in a remote,
cooler area outside the fixture.
• Planned lamp maintenance – the organized
replacement of failed and failing lamps,
particularly with preheat or slimline systems.
• Use of special LOW HEAT (-LH) rise, VERY LOW
HEAT (-VLH) rise, and SUPER LOW HEAT (-SLH)
rise ballasts where available and necessary.
LOW-LEAKAGE CURRENT
TO GROUND BALLASTS
Many one- and two-lamp, 30- and 40-watt high
power rapid start ballasts, and two- and three-lamp
20-watt trigger start ballasts, meet requirements for
“low-leakage-current-to-ground.” Those most fre-
quently used in low-leakage applications are listed
in the next column.
All high power factor ballasts are equipped
with capacitators. Oil-filled capacitators
contain non-resetting internal protection
and are manufactured without PCBs.
TYPICAL SPECIFICATIONS FOR
ELECTROMAGNETIC BALLASTS
T12
2-9
For more information, visit www.gelighting.com
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D1 6 7/16 1 7/8 1 1/2 6 -
D2 9 1/2 2 3/8 1 1/2 8 57/64 1 11/16
W
H
L
M
D
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number
NOM
(Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F30T12 - High Power Factor
86287 1 Rapid 277 697-L-TC-P-IP .16 44 .98 2.23 < 1.7 < 20 50/10 A 42 D2
86251 2 Rapid 120 573-L-TC-P-IP .66 79 .95 1.21 < 1.7 < 20 50/10 A 1 D2
86253 2 Rapid 277 588-L-TC-P-IP .29 79 .96 1.21 < 1.7 < 20 50/10 A 1 D2
F30T12 - Normal Power Factor
86105 1 Rapid 120 413-C-TC-P-IP .63 37 .72 1.95 < 1.7 < 10 50/10 A 8 D1
F30T12/WM - High Power Factor
86251 2 Rapid 120 573-L-TC-P-IP .57 67 .89 1.33 < 1.9 < 20 60/15 A 1 D2
86253 2 Rapid 277 588-L-TC-P-IP .26 70 .92 1.31 < 1.9 < 20 60/15 A 1 D2
F30T12 AND F30T12/WM LAMPS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number
NOM
(Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F40T12 - High Power Factor
86101 1 Rapid 120 412-L-SLH-TC-P-IP•••• •.45 52 .95 1.83 < 1.7 < 20 50/10 A 42 D2
86158 1 Rapid 277 458-L-SLH-TC-P-IP•••• •.19 51 .95 1.86 < 1.7 < 20 50/10 A 42 D2
86110 2 Hybrid 120 420-L-TC-P-IP•••• .62 72 .85 1.18 < 1.7 < 20 50/10 A 1 D2
86137 2 Rapid 120 446-L-SLH-TC-P .75 89 .94 1.06 < 1.7 < 20 50/10 A 1 D2
86208 2 Hybrid 277 537-L-TC-P-IP•••• .31 82 .94 1.15 < 1.7 < 20 50/10 A 1 D2
86123 2 Rapid 277 443-L-SLH-TC-P .34 90 .95 1.06 < 1.7 < 20 50/10 A 1 D2
F40T12- Normal Power Factor
86105 1 Rapid 120 413-C-TC-P-IP•• •.53 36 .61 1.69 < 1.7 < 20 50/10 A 8 D1
F40T12 LAMPS
Not for use with “U” lamps
Not for use with Energy Saver “U” lamps
For Residential Use Only
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F40T12/WM - High Power Factor
86101 1 Rapid 120 412-L-SLH-TC-P-IP•••• •.38 44 .88 2.00 < 1.9 < 20 60/15 A 42 D2
86158 1 Rapid 277 458-L-SLH-TC-P-IP•••• •.17 44 .88 2.00 < 1.85 < 20 60/15 A 42 D2
86110 2 Hybrid 120 420-L-TC-P-IP•••• .50 59 .80 1.36 < 1.9 < 20 60/15 A 1 D2
86137 2 Rapid 120 446-L-SLH-TC-P .65 74 .90 1.22 < 1.9 < 20 60/15 A 1 D2
86123 2 Rapid 277 443-L-SLH-TC-P .28 74 .90 1.22 < 1.9 < 20 60/15 A 1 D2
86208 2 Hybrid 277 537-L-TC-P-IP•••• .26 70 .91 1.30 < 1.9 < 20 60/15 A 1 D2
F40T12/WM - Normal Power Factor
86105 1 Rapid 120 413-C-TC-P-IP•• •.61 33 .68 2.06 < 1.9 < 20 60/15 A 8 D1
F40T12/WM LAMPS
DIMENSIONS
Not for use with “U” lamps
Not for use with Energy Saver “U” lamps
For Residential Use Only
For more information, visit www.gelighting.com
2-9
ELECROMAGNETIC
FLUORESCENT BALLASTS
transforming the power of light
2-8
ELECROMAGNETIC
FLUORESCENT BALLASTS
LEAD LENGTHS
Black Black/White White Red Blue Yellow Blue/White Brown
LEAD LENGTHS
Catalog
Number
GE
Product
Code
Quantity
Exit
Length
Quantity
Exit
Length
Quantity
Exit
Length
Quantity
Exit
Length
Quantity
Exit
Length
Quantity
Exit
Length
Quantity
Exit
Length
Quantity
Exit
Length
86071 200-C-S-P-IP 1 R 13 2 R 13 1 R 27 1 R 27 1 R 27
86073 200-H2-IP 2 8-15
86078 202-B-TC-P-IP 1 L 8 1 L 27 1 R 26
86080 202-SB-TC-IP 1 12 2 32-12 1 26 1 26 1 32
86085 213-TC-P-IP 1 L 41 1 L 41 1 R 23 1 R 23
86105 413-C-TC-P-IP 1 L 9 1 L 29 2 R 30 1 L 29
86110 420-L-TC-P-IP 1 L 20 1 L 20 2 R 24 2 R 24 2 L 36
86123 443-L-SLH-TC-P 1 L 22 1 L 22 2 R 26 2 R 26 2 L 36
86132 445-RS-WS-TC-P-IP 1 L 10 2 L/R 10 2 R 9 1 R 9
86137 446-L-SLH-TC-P 1 L 22 1 L 22 2 R 26 2 R 26 2 L 36
86144 447-LR-TC-P-IP 1 L 10 1 L 10 2 R 13 2 R 13 2 L 18
86158 458-L-SLH-TC-P-IP 1 L 25 1 L 25 2 L 37 2 R 27 2 R 27
86164 480-SLH-TC-P-IP 1 L 18 1 L 18 2 R 46 2 R 46 2 L 65
86167 480-XLH-TC-P-IP 1 L 18 1 L 18 2 R 46 2 R 46 2 L 65
86171 487-SLH-TC-P-IP 1 L 18 1 L 18 2 R 46 2 R 46 2 L 65
86173 487-XLH-TC-P-IP 1 L 18 1 L 18 2 R 46 2 R 46 2 L 65
86176 490-XLH-TC-P-IP 1 L 18 1 L 18 2 R 33 2 R 33 2 L 51
86185 502-A-TC-P-IP 1 L 20 1 L 38 2 R 26 1 L 38 2 R 26 1 L 38 1 R 20
86206 532-BR-TC-P-IP 1 L 10 1 L 42 1 R 27 1 R 27 2 L 42
86208 537-L-TC-P-IP 1 L 20 1 L 20 2 R 24 2 R 24 2 L 36
86222 546-B-TC-P-IP 1 L 10 1 L 17 2 R 12 1 L 17
86227 547-RS-WS-TC-P-IP 1 L 10 2 L/R 10 2 R 9 1 R 9
86231 548-H2-IP 2 9
86240 554-L-TC-P-IP 1 L 10 1 L 10 2 R 13 2 R 13 2 L 16
86243 562-L-TC-P-IP 1 L 10 1 L 10 2 L 10 2 R 10
86245 564-L-TC-P-IP 1 L 10 1 L 10 2 R 13 2 R 13 2 L 16
86251 573-L-TC-P-IP 1 L 22 1 L 22 2 R 25 2 R 25 2 L 26
86253 588-L-TC-P-IP 1 L 22 1 L 22 2 R 25 2 R 25 2 L 26
86264 627-LH-TC-P-IP 1 L 18 1 L 18 2 R 20 2 R 20 2 L 32
86287 697-L-TC-P-IP 1 L 20 1 L 20 2 L 26 2 R 26 2 R 23
86341 754-L-TC-P-IP 1 L 22 1 L 22 2 R 26 2 R 26 2 L 36
86351 798-XLH-TC-P-IP 1 L 18 1 18 2 33 2 33 2 51
86359 806-SLH-TC-P 1 L 68 1 L 68 1 R 44 1 R 44
86372 822-BR-TC-P-IP 1 L 8 1 L 68 1 R 44
86378 827-SLH-TC-P 1 L 68 1 L 68 1 R 44 1 R 45 2 L 61.5
86381 828-BR-TC-P-IP 1 8 1 L 68 1 R 44
86396 881-BR-TC-P-IP 1 L 68 1 L 68 1 R 44 1 R 44
86402 930-K-TC-P-IP 1 L 18 1 L 18 2 R 46 2 R 46 2 L 65
86411 937-K-TC-P-IP 1 L 18 1 L 18 2 R 46 2 R 46 2 L 65
86430 957-S-TC-P-IP 1 L 10 1 L 10 2 R 49 2 L 52
86432 960-VLH-TC-P-IP 1 L 20 1 L 20 2 R 38 2 R 38 2 L 47
Lead Quantities (per color)
Exits (L=Left, R=Right, B=Bottom)
Lengths (in inches, +/- 1")
T10
2-11
For more information, visit www.gelighting.com
ELECROMAGNETIC
FLUORESCENT BALLASTS
T12
transforming the power of light
2-10
FOR F40T10 LAMPS
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D2 9 1/2 2 3/8 1 1/2 8 57/64 1 11/16
W
H
L
M
D
DIMENSIONS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F40T10 - High Power Factor
86101 1 Rapid 120 412-L-SLH-TC-P-IP .45 52 .90 1.73 < 1.7 < 20 50/10 A 42 D2
86158 1 Rapid 277 458-L-SLH-TC-P-IP .19 51 .90 1.76 < 1.7 < 20 50/10 A 42 D2
86110 2 Hybrid 120 420-L-TC-P-IP .65 74 .85 1.15 < 1.7 < 32 50/10 A 1 D2
86137 2 Rapid 120 446-L-SLH-TC-P .76 90 .95 1.06 < 1.7 < 20 50/10 A 1 D2
86123 2 Rapid 277 443-L-SLH-TC-P .33 90 .95 1.06 < 1.7 < 20 50/10 A 1 D2
86208 2 Hybrid 277 537-L-TC-P-IP .32 85 .95 1.12 < 1.7 < 20 50/10 A 1 D2
ELECROMAGNETIC
FLUORESCENT BALLASTS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F40T12/U - High Power Factor
86110 2 Hybrid 120 420-L-TC-P-IP•••• .64 74 .83 1.12 < 1.7 < 32 50/10 A 1 D2
86137 2 Rapid 120 446-L-SLH-TC-P .76 90 .93 1.03 < 1.7 < 20 50/10 A 1 D2
86208 2 Hybrid 277 537-L-TC-P-IP•••• .32 87 .94 1.08 < 1.7 < 20 50/10 A 1 D2
86123 2 Rapid 277 443-L-SLH-TC-P .34 92 .95 1.03 < 1.7 < 20 50/10 A 1 D2
Not for use with Energy Saver “U” lamps
F40T12/U LAMPS
FOR F40T12/WM/U, F48" 25W/UTLS
AND WORKLITE 25 LAMPS
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D1 6 7/16 1 7/8 1 1/2 6 -
D2 9 1/2 2 3/8 1 1/2 8 57/64 1 11/16
DIMENSIONS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F40T12/WM/U - High Power Factor
86137 2 Rapid 120 446-L-SLH-TC-P .65 74 .90 1.22 < 1.9 < 20 60/15 A 1 D2
86123 2 Rapid 277 443-L-SLH-TC-P .28 74 .90 1.22 < 1.9 < 20 60/15 A 1 D2
F48”25W/UTLS & WORKLITE - Normal Power Factor
86105 1 Rapid 120 413-C-TC-P-IP•• •.51 32 .90 2.79 < 1.7 < 20 50/10 A 8 D1
For Residential Use Only
T12HO
2-13
For more information, visit www.gelighting.com
ELECROMAGNETIC
FLUORESCENT BALLASTS
transforming the power of light
2-12
FOR F72T12HO LAMPS
DIMENSIONS
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D7 11 3/4 3 3/16 2 5/8 11 9/64 2
W
H
L
M
D
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F72T12HO - High Power Factor
86174 1 Rapid 120 490-XLH-TC-P .95 107 .86 0.80 < 2.0 > 32 -20/-29 B 15 D7
86164 2 Rapid 120 480-SLH-TC-P-IP 1.69 196 .97 0.49 < 1.9 < 20 -20/-29 B 1 D7
86167 2 Rapid 120 480-XLH-TC-P-IP 1.69 196 .97 0.49 < 1.9 < 20 -20/-29 B 1 D7
86174 2 Rapid 120 490-XLH-TC-P 1.50 177 .92 0.52 < 1.7 < 10 -20/-29 B 1 D7
86171 2 Rapid 277 487-SLH-TC-P-IP .74 197 .96 0.48 < 1.7 < 20 -20/-29 B 1 D7
86173 2 Rapid 277 487-XLH-TC-P-IP .78 208 .95 0.46 < 1.7 < 20 -20/-29 B 1 D7
Power Factor Corrected to >85%
FOR F72T12HO LAMPS
See product overview pages for electromagnetic fluorescent ballasts for additional information on weatherproof applications.
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F72T12HO - High Power Factor - Tanning
86351 2 Rapid 120 798-XLH-TC-P-IP 1.89 224 1.06 0.47 < 1.7 < 20 50/10 B 1 D7
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F84T12HO - High Power Factor
86164 2 Rapid 120 480-SLH-TC-P-IP 1.87 220 .93 0.42 < 1.9 < 20 -20/-29 B 1 D7
86167 2 Rapid 120 480-XLH-TC-P-IP 1.98 235 .93 0.40 < 1.9 < 20 -20/-29 B 1 D7
86171 2 Rapid 277 487-SLH-TC-P-IP .87 235 .97 0.41 < 1.9 < 20 -20/-29 B 1 D7
86173 2 Rapid 277 487-XLH-TC-P-IP .89 244 .95 0.39 < 1.9 < 20 -20/-29 B 1 D7
FOR F84T12HO LAMPS
FOR F96T12HO AND
F96T12HO/WM LAMPS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F96T12HO - High Power Factor
86174 1 Rapid 120 490-XLH-TC-P 1.10 124 .85 0.65 < 2.0 < 20 -20/-29 B 15 D7
86164 2 Rapid 120 480-SLH-TC-P-IP 1.99 237 .96 0.41 < 1.7 < 10 -20/-29 B 1 D7
86167 2 Rapid 120 480-XLH-TC-P-IP 2.15 250 .96 0.39 < 1.7 < 10 -20/-29 B 1 D7
86171 2 Rapid 277 487-SLH-TC-P-IP .87 237 .95 0.40 < 1.7 < 10 -20/-29 B 1 D7
86173 2 Rapid 277 487-XLH-TC-P-IP .95 261 .97 0.37 < 1.7 < 10 -20/-29 B 1 D7
F96T12HO/WM - High Power Factor
86174 1 Rapid 120 490-XLH-TC-P .94 106 .81 0.76 < 2.0 < 32 60/15 B 15 D7
86164 2 Rapid 120 480-SLH-TC-P-IP 1.72 202 .89 0.44 < 1.9 < 20 60/15 B 1 D7
86167 2 Rapid 120 480-XLH-TC-P-IP 1.80 209 .89 0.43 < 1.9 < 20 60/15 B 1 D7
86171 2 Rapid 277 487-SLH-TC-P-IP .75 205 .91 0.44 < 1.9 < 20 60/15 B 1 D7
86173 2 Rapid 277 487-XLH-TC-P-IP .83 223 .92 0.41 < 1.9 < 20 60/15 B 1 D7
For more information, visit www.gelighting.com
ELECROMAGNETIC
FLUORESCENT BALLASTS
T12HO
W
H
L
M
D
FOR F24, F30, F36 AND
F42T12HO LAMPS
FOR F48T12HO LAMPS
DIMENSIONS
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D6 11 3/4 3 1/8 1 25/32 11 9/64 2
D7 11 3/4 3 3/16 2 5/8 11 9/64 2
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F24T12HO - High Power Factor
86174 2 Rapid 120 490-XLH-TC-P .95 103 .81 0.79 < 2.0 > 32 -20/-29 B 1 D7
86264 2 Rapid 277 627-LH-TC-P-IP .40 103 .94 0.91 < 1.9 < 32 50/10 B 1 D6
F36T12HO - High Power Factor
86174 2 Rapid 120 490-XLH-TC-P 1.06 121 .84 0.69 < 2.0 < 32 50/10 B 1 D7
86264 2 Rapid 277 627-LH-TC-P-IP .48 128 .98 0.77 < 1.7 < 20 50/10 B 1 D6
F42T12HO - High Power Factor
86174 2 Rapid 120 490-XLH-TC-P 1.12 130 .86 0.66 < 2.0 < 32 50/10 B 1 D7
86264 2 Rapid 120 627-LH-TC-P-IP .51 139 .98 0.71 < 1.7 < 20 50/10 B 1 D6
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F48T12HO - High Power Factor
86174 1 Rapid 120 490-XLH-TC-P•• .82 82 .81 0.99 < 2.0 > 32 -20/-29 B 15 D7
86174 2 Rapid 120 490-XLH-TC-P 1.18 139 .87 0.63 < 2.0 < 20 -20/-29 B 1 D7
86264 2 Rapid 277 627-LH-TC-P-IP .55 150 .99 0.66 < 1.7 < 20 50/10 B 1 D6
Power Factor Corrected to >70%
FOR F48T12HO/WM AND
F60T12HO LAMPS
FOR F60 AND F64T12HO LAMPS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F48T12HO/WM - High Power Factor
86174 1 Rapid 120 490-XLH-TC-P•• .80 76 .78 1.03 < 2.0 > 32 60/15 B 15 D7
86174 2 Rapid 120 490-XLH-TC-P 1.07 124 .83 0.67 < 2.0 < 32 60/15 B 1 D7
86264 2 Rapid 277 627-LH-TC-P-IP .49 131 .92 0.70 < 1.9 < 20 60/15 B 1 D6
F60T12HO - High Power Factor
86174 1 Rapid 120 490-XLH-TC-P .92 99 .83 0.84 < 2.0 > 32 -20/-29 B 15 D7
86174 2 Rapid 120 490-XLH-TC-P 1.42 169 .89 0.53 < 2.0 < 20 -20/-29 B 1 D7
Power Factor Corrected to >70%
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F64T12HO - High Power Factor
86174 1 Rapid 120 490-XLH-TC-P .93 101 .84 0.83 < 1.9 > 32 -20/-29 B 15 D7
86174 2 Rapid 120 490-XLH-TC-P 1.50 178 .89 0.50 < 1.9 < 20 -20/-29 B 1 D7
T12VHO
2-15
For more information, visit www.gelighting.com
ELECROMAGNETIC
FLUORESCENT BALLASTS
transforming the power of light
2-14
FOR F96T12VHO AND
F96T12VHO/WM LAMPS
FOR F96PG17 AND
F96PG17/WM LAMPS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F96PG17 - High Power Factor
86430 1 Rapid 277 957-S-TC-P-IP .83 192 .79 0.41 < 1.9 < 32 -20/-29 C 12 D8
86402 2 Rapid 120 930-K-TC-P-IP•• 3.83 446 .98 0.22 < 1.7 < 20 -20/-29 D 1 D8
86411 2 Rapid 277 937-K-TC-P-IP•• 1.61 429 .95 0.22 < 1.7 < 20 -20/-29 D 1 D8
F96PG17/WM - High Power Factor
86430 1 Rapid 277 957-S-TC-P-IP .79 175 .76 0.43 < 1.9 < 32 60/15 C 12 D8
Cannot be used with T10 or T10J lamps
DIMENSIONS
W
H
L
M
D
See product overview pages for electromagnetic fluorescent ballasts for additional information on weatherproof applications.
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D8 14 5/16 3 3/16 2 5/8 13 3/4 2
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F96T12VHO - High Power Factor
86430 1 Rapid 277 957-S-TC-P-IP•• .81 197 .78 0.40 < 1.9 < 32 -20/-29 C 12 D8
86402 2 Rapid 120 930-K-TC-P-IP•• 4.10 482 .99 0.21 < 1.7 < 20 -20/-29 D 1 D8
86411 2 Rapid 277 937-K-TC-P-IP•• 1.64 450 .95 0.21 < 1.7 < 20 -20/-29 D 1 D8
F96T12VHO/WM - High Power Factor
86430 1 Rapid 277 957-S-TC-P-IP•• .79 183 .77 0.42 < 1.9 < 32 60/15 C 12 D8
Power Factor Corrected to >70%
Cannot be used with T10 or T10J lamps
For more information, visit www.gelighting.com
T12VHO
ELECROMAGNETIC
FLUORESCENT BALLASTS
DIMENSIONS
W
H
L
M
D
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F48PG17 - High Power Factor
86432 2 Rapid 120 960-VLH-TC-P-IP•• 1.60 175 .70 0.40 < 2.0 < 32 -20/-29 C 1 D8
F48T12VHO - High Power Factor
86432 2 Rapid 120 960-VLH-TC-P-IP•• 1.62 185 .72 0.39 < 2.0 < 32 -20/-29 C 1 D8
May be used with equivalent T10 or T10J lamps.
FOR F48PG17 AND
F48T12VHO LAMPS
See product overview pages for electromagnetic fluorescent ballasts for additional information on weatherproof applications.
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F72PG17 - High Power Factor
86430 1 Rapid 277 957-S-TC-P-IP•• .76 157 .77 0.49 < 1.9 > 32 -20/-29 C 12 D8
86402 2 Rapid 120 930-K-TC-P-IP•• 3.05 360 .95 0.26 < 1.7 < 20 -20/-29 D 1 D8
86432 2 Rapid 120 960-VLH-TC-P-IP•• 2.01 239 .72 0.30 < 1.9 < 20 -20/-29 C 1 D8
86411 2 Rapid 277 937-K-TC-P-IP•• 1.26 341 .92 0.27 < 1.7 < 20 -20/-29 D 1 D8
F72T12VHO - High Power Factor
86430 1 Rapid 277 957-S-TC-P-IP•• .75 161 .79 0.49 < 1.9 > 32 -20/-29 C 12 D8
86402 2 Rapid 120 930-K-TC-P-IP•• 3.05 360 .95 0.26 < 1.7 < 20 -20/-29 D 1 D8
86432 2 Rapid 120 960-VLH-TC-P-IP•• 2.08 248 .79 0.32 < 1.9 < 20 -20/-29 C 1 D8
86411 2 Rapid 277 937-K-TC-P-IP•• 1.26 341 .91 0.27 < 1.7 < 20 -20/-29 D 1 D8
Power Factor Corrected to >70%
Cannot be used with T10 or T10J lamps
May be used with equivalent T10 or T10J lamps
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D8 14 5/16 3 3/16 2 5/8 13 3/4 2
FOR F72PG17 AND
F72T12VHO LAMPS
2-17
For more information, visit www.gelighting.com
ELECROMAGNETIC
FLUORESCENT BALLASTS
transforming the power of light
2-16
T12 SLIMLINE
DIMENSIONS
W
H
L
M
D
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D6 11 3/4 3 1/8 1 25/32 11 9/64 2
D12 11 3/4 3 3/16 1 25/32 11 9/64 2
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F96T12 - High Power Factor
86372 1 Instant 120 822-BR-TC-P-IP .84 96 .95 0.98 < 1.85 < 32 0/-18 C 34 D6
86381 1 Instant 277 828-BR-TC-P-IP .35 93 .93 1.00 < 1.85 < 32 0/-18 C 34 D6
86378 2 Instant 277 827-SLH-TC-P-IP .58 158 .93 0.59 < 1.85 < 10 50/10 C 40 D12
F96T12/WM - High Power Factor
86372 1 Instant 120 822-BR-TC-P-IP .70 79 .90 1.14 < 2.0 < 32 60/15 C 34 D6
86381 1 Instant 277 828-BR-TC-P-IP .30 79 .96 1.22 < 2.0 < 32 60/15 C 34 D6
86378 2 Instant 277 827-SLH-TC-P-IP .48 132 .89 0.67 < 2.0 < 20 60/15 C 40 D12
FOR F96T12 AND
F96T12/WM LAMPS
For more information, visit www.gelighting.com
T12 SLIMLINE
ELECROMAGNETIC
FLUORESCENT BALLASTS
DIMENSIONS
W
H
L
M
D
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D6 11 3/4 3 1/8 1 25/32 11 9/64 2
D10 9 29/64 3 3/32 1 25/32 8 57/64 1 11/16
D12 11 3/4 3 3/16 1 25/32 11 9/64 2
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F24T12 - High Power Factor
86206 2 Instant 277 532-BR-TC-P-IP•• .29 60 .96 1.60 < 1.85 < 32 32 / 0 B 40 D6
F36T12 - High Power Factor
86085 2 Instant 120 213-TC-P-IP .70 77 .95 1.24 < 1.85 > 32 50/10 B 39 D10
86206 2 Instant 277 532-BR-TC-P-IP•• .34 75 .93 1.24 < 1.85 < 32 32 / 0 B 40 D12
F40T12 /IS - Bi Pin - High Power Factor
86085 2 Instant 120 213-TC-P-IP .80 94 .92 0.98 < 1.85 < 20 50/10 B 39 D10
86206 2 Instant 277 532-BR-TC-P-IP .37 94 .92 0.98 < 1.85 < 32 32 / 0 B 40 D12
F42T12 - High Power Factor
86085 2 Instant 120 213-TC-P-IP .74 86 .93 1.09 < 2.0 < 32 50/10 B 39 D10
86206 2 Instant 277 532-BR-TC-P-IP .34 84 .94 1.11 < 1.85 < 32 32 / 0 B 40 D12
F48T12 - High Power Factor
86085 2 Instant 120 213-TC-P-IP .79 95 .92 0.89 < 1.85 < 20 50/10 B 39 D10
86206 2 Instant 277 532-BR-TC-P-IP .35 95 .96 1.01 < 1.85 < 32 32 / 0 B 40 D12
F48T12/WM - High Power Factor
86085 2 Instant 120 213-TC-P-IP .72 80 .91 1.14 < 2.0 < 32 60/15 B 39 D10
86206 2 Instant 277 532-BR-TC-P-IP .32 82 .94 1.15 < 2.0 < 32 60/15 B 40 D12
Power Factor Corrected to >75%
FOR F24 - F48T12 LAMPS
FOR F60 - F84T12 LAMPS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F60T12 - High Power Factor
86396 2 Instant 120 881-BR-TC-P-IP•• .96 109 .84 0.77 < 1.85 < 32 0/-18 C 39 D6
F64T12 - High Power Factor
86396 2 Instant 120 881-BR-TC-P-IP •• 1.05 119 .84 0.71 < 1.85 < 32 0/-18 C 39 D6
F72T12 - High Power Factor
86372 1 Instant 120 822-BR-TC-P-IP .72 81 .95 1.17 < 1.85 < 32 0/-18 C 34 D6
86381 1 Instant 277 828-BR-TC-P-IP .30 78 .92 1.18 < 1.85 < 32 0/-18 C 34 D6
86359 2 Instant 120 806-SLH-TC-P 1.13 133 1.01 0.76 < 1.85 < 20 50/10 C 39 D6
86396 2 Instant 120 881-BR-TC-P-IP 1.03 120 .82 0.69 < 1.85 < 32 0/-18 C 39 D6
86378 2 Instant 277 827-SLH-TC-P-IP .49 135 .93 0.69 < 1.85 < 20 50/10 C 40 D12
F84T12 - High Power Factor
86372 1 Instant 120 822-BR-TC-P-IP .77 89 .96 1.09 < 1.85 < 32 0/-18 C 34 D6
86381 1 Instant 277 828-BR-TC-P-IP .33 86 .94 1.09 < 1.85 < 32 0/-18 C 34 D6
86359 2 Instant 120 806-SLH-TC-P 1.26 143 .95 0.67 < 1.85 < 20 50/10 C 39 D6
86378 2 Instant 277 827-SLH-TC-P-IP .55 150 .95 0.63 < 1.85 < 10 50/10 C 40 D12
Use with any combination of F60T12 & F64T12
2-19
For more information, visit www.gelighting.com
ELECROMAGNETIC
FLUORESCENT BALLASTS
transforming the power of light
2-18
PREHEAT/TRIGGER
DIMENSIONS
W
H
L
M
D
L
L
M
M
W
3/32" Slots
E
H
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F4T5 - Normal Power Factor
86231 1 Preheat 120 548-H2-IP•• .17 8 1.00 12.5 < 1.7 <10 50/10 A 21 E1
Requires Starter
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D1 6 7/16 1 7/8 1 1/2 6 -
D2 9 1/2 2 3/8 1 1/2 8 57/64 1 11/16
D3 6 19/32 2 3/8 1 1/2 6 -
D11 6 7/16 1 7/8 1 5/16 6 -
E1 3 1/16 1 25/32 1 5/16 2 3/4 -
FOR F4 AND F6T5 LAMPS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F14T8 - Normal Power Factor
86071 1 Preheat 120 200-C-S-P-IP•• .42 22 1.07 4.89 < 1.7 <10 50/10 A 28 D11
86073 1 Preheat 120 200-H2-IP•• •.36 19 .99 5.15 < 1.7 <10 50/10 A 21 E1
F14T12 - Normal Power Factor
86243 1 Preheat 277 562-L-TC-P-IP .11 28 .75 2.68 < 2.0 <32 50/10 A 12 D2
86245 2 Preheat 120 564-L-TC-P-IP .39 45 .79 1.75 < 1.7 <20 50/10 A 1 D2
86240 2 Preheat 277 554-L-TC-P-IP .17 45 .79 1.76 < 1.9 <20 50/10 A 1 D2
F14T12 - Normal Power Factor
86071 1 Preheat 120 200-C-S-P-IP•• .43 22 1.11 4.96 < 1.7 <10 50/10 A 28 D11
86073 1 Preheat 120 200-H2-IP•• •.37 20 .98 4.85 < 1.7 <10 50/10 A 21 E1
86222 1 Preheat 120 546-B-TC-P-IP•• •.66 30 .86 2.87 < 1.7 <10 50/10 A 8 D1
Starter is built in as an integral component
Requires one circuit interrupting lamp holder
Requires Starter
FOR F14T8 AND F14T12 LAMPS
FOR F15T8 LAMPS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F15T8 - High Power Factor
86243 1 Preheat 277 562-L-TC-P-IP .12 28 .88 3.16 < 2.0 <32 50/10 A 12 D2
86245 2 Preheat 120 564-L-TC-P-IP .47 51 .91 1.78 < 1.7 <32 50/10 A 1 D2
86240 2 Preheat 277 554-L-TC-P-IP .20 51 .89 1.76 < 1.9 <20 50/10 A 1 D2
F15T8 - Normal Power Factor
86071 1 Preheat 120 200-C-S-P-IP•• .36 22 1.05 4.86 < 1.7 <10 50/10 A 28 D11
86073 1 Preheat 120 200-H2-IP•• •.32 20 1.05 5.13 < 1.7 <10 50/10 A 21 E1
86222 1 Preheat 120 546-B-TC-P-IP•• •.55 25 .89 3.50 < 1.7 <10 50/10 A 8 D1
86144 2 Preheat 120 447-LR-TC-P-IP .50 39 .75 1.92 < 1.7 <20 50/10 A 1 D3
Starter is built in as an integral component
Requires one circuit interrupting lamp holder
Requires Starter
For more information, visit www.gelighting.com
CIRCLINE
ELECROMAGNETIC
FLUORESCENT BALLASTS
DIMENSIONS
W
H
L
M
D
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D1 6 7/16 1 7/8 1 1/2 6 -
D11 6 7/16 1 7/8 1 5/16 6 -
E1 3 1/16 1 25/32 1 5/16 2 3/4 -
L
L
M
M
W
3/32" Slots
E
H
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
FC6T9 (20 Watt) - Normal Power Factor
86071 1 Preheat 120 200-C-S-P-IP•• .40 29 1.01 3.47 < 1.7 <10 50/10 A 28 D11
86073 1 Preheat 120 200-H2P-IP•• .34 20 .94 4.66 < 1.7 <10 50/10 A 21 E1
86227 1 Rapid 120 547-RS-WS-TC-P-IP .64 27 .90 3.30 < 1.7 < 10 50/10 A 29 D1
FC8T9 (22 Watt) - Normal Power Factor
86071 1 Preheat 120 200-C-S-P-IP•• .24 22 .93 4.19 < 1.7 <10 50/10 A 28 D11
86073 1 Preheat 120 200-H2P-IP•• .30 20 .83 4.08 < 1.7 <10 50/10 A 21 E1
86227 1 Rapid 120 547-RS-WS-TC-P-IP•• .60 30 .85 2.83 < 1.7 < 10 50/10 A 29 D1
Also available in White Cans
Starter is built in as an integral component
Requires Starter
FOR 20, 22 AND 32 WATT LAMPS
FOR 32 AND 40 WATT LAMPS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
FC12T9 (32 Watt) - Normal Power Factor
86078 1 Preheat 120 202-B-TC-P-IP•• .67 37 .91 2.44 < 1.7 <10 50/10 A 22 D11
86080 1 Preheat 120 202-SB-TC-P-IP•• .67 37 .91 2.44 < 1.7 <10 50/10 A 28 D11
86132 1 Rapid 120 445-RS-WS-TC-P-IP•• .60 35 .68 1.97 < 1.7 < 20 50/10 A 29 D1
FC16T9 (40 Watt) - Normal Power Factor
86132 1 Rapid 120 445-RS-WS-TC-P-IP•• .55 33 .60 1.83 < 1.7 < 20 50/10 A 29 D1
Also available in White Cans
Starter is built in as an integral component
Requires Starter
2-21
For more information, visit www.gelighting.com
ELECROMAGNETIC
FLUORESCENT BALLASTS
transforming the power of light
2-20
PREHEAT/TRIGGER &
DIMMING
DIMENSIONS
W
H
L
M
D
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D11 6 7/16 1 7/8 1 5/16 6 -
D5 16 3/8 2 3/8 1 1/2 15 25/32 1 11/16
PREHEAT/TRIGGER
FOR F40T10 AND F40T12 LAMPS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F40T10 - Normal Power Factor
86078 1 Preheat/RS 120 202-B-TC-P-IP•• .56 38 .77 2.05 < 1.7 <20 50/10 A 22 D11
86080 1 Preheat/RS 120 202-SB-TC-P-IP•• .56 38 .77 2.05 < 1.7 <20 50/10 A 28 D11
F40T12 - Normal Power Factor
86078 1 Preheat/RS 120 202-B-TC-P-IP•• .60 39 .77 1.99 < 1.7 <10 50/10 A 22 D11
86080 1 Preheat/RS 120 202-SB-TC-P-IP•• .60 39 .77 1.99 < 1.7 <10 50/10 A 28 D11
F40T12/WM - Normal Power Factor
86078 1 Preheat/RS 120 202-B-TC-P-IP•• .68 37 .82 2.22 < 1.9 <10 60/15 A 22 D11
86080 1 Preheat/RS 120 202-SB-TC-P-IP•• .68 37 .82 2.22 < 1.9 <10 60/15 A 28 D11
Starter is built in as an integral component
Requires Starter
PREHEAT/TRIGGER
ELECROMAGNETIC
FLUORESCENT BALLASTS
DIMENSIONS
W
H
L
M
D
L
L
M
M
W
3/32" Slots
E
H
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D1 6 7/16 1 7/8 1 1/2 6 -
D2 9 1/2 2 3/8 1 1/2 8 57/64 1 11/16
D3 6 19/32 2 3/8 1 1/2 6 -
D11 6 7/16 1 7/8 1 5/16 6 -
E1 3 1/16 1 25/32 1 5/16 2 3/4 -
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F15T12 - High Power
86243 1 Preheat 277 562-L-TC-P-IP .11 28 .85 3.04 < 2.0 <32 50/10 A 12 D2
86245 2 Preheat 120 564-L-TC-P-IP .43 44 .85 1.91 < 1.7 <20 50/10 A 1 D2
86240 2 Preheat 277 554-L-TC-P-IP .20 49 .87 1.78 < 1.9 <20 50/10 A 1 D2
F15T12 - Normal Power
86071 1 Preheat 120 200-C-S-P-IP•• .41 23 1.20 5.26 < 1.7 <10 50/10 A 28 D11
86073 1 Preheat 120 200-H2-IP•• •.44 21 1.08 5.19 < 1.7 <10 50/10 A 21 E1
86222 1 Preheaat 120 546-B-TC-P-IP•• •.61 30 .96 3.23 < 1.7 <10 50/10 A 8 D1
86144 2 Preheat 120 447-LR-TC-P-IP .56 42 .80 1.90 < 1.7 <20 50/10 A 1 D3
F18T8 - Normal Power
86071 1 Preheat 120 200-C-S-P-IP•• .33 21 .91 4.31 < 1.7 <10 50/10 A 28 D11
86073 1 Preheat 120 200-H2-IP•• •.28 19 .80 4.29 < 1.7 <10 50/10 A 21 E1
F19T8 - Normal Power
86071 1 Preheat 120 200-C-S-P-IP•• .31 21 .91 4.28 < 1.7 <10 50/10 A 28 D11
86073 1 Preheat 120 200-H2-IP•• •.26 18 .80 4.33 < 1.7 <10 50/10 A 21 E1
Starter is built in as an integral component
Requires Starter
Requires one circuit interrupting lamp holder
FOR F15T12, F18T8
AND F19T8 LAMPS
FOR F20, F25, F30T12
AND F30T8 LAMPS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F20T12 - High Power Factor
86243 1 Preheat 277 562-L-TC-P-IP .12 30 .81 2.73 < 1.9 <32 50/10 A 12 D2
86245 2 Preheat 120 564-L-TC-P-IP .51 55 .85 1.55 < 1.7 <20 50/10 A 1 D2
86240 2 Preheat 277 554-L-TC-P-IP .22 55 .86 1.55 < 1.7 <20 50/10 A 1 D2
F20T12 - Normal Power Factor
86071 1 Preheat 120 200-C-S-P-IP•• .35 23 .95 4.15 < 1.7 <10 50/10 A 28 D11
86073 1 Preheat 120 200-H2-IP•• •.30 20 .83 4.15 < 1.7 <10 50/10 A 21 E1
86222 1 Preheat 120 546-B-TC-P-IP•• •.58 29 .82 2.83 < 1.7 <10 50/10 A 8 D1
86144 2 Preheat 120 447-LR-TC-P-IP .43 37 .56 1.51 < 1.7 <20 50/10 A 1 D3
F30T8 - Normal Power Factor
86078 1 Preheat 120 202-B-TC-P-IP•• .62 37 .97 2.62 < 1.7 <10 50/10 A 22 D11
86080 1 Preheat 120 202-SB-TC-P-IP•• .62 39 2.97 7.62 < 1.7 <10 50/10 A 28 D11
F30T12 - Normal Power Factor
86078 1 Preheat/RS 120 202-B-TC-P-IP•• .68 37 .85 2.28 < 1.7 <10 50/10 A 22 D11
86080 1 Preheat/RS 120 202-SB-TC-P-IP•• .68 37 .85 2.28 < 1.7 <10 50/10 A 28 D11
Starter is built in as an integral component
Requires Starter
Requires one circuit interrupting lamp holder
60HZ
DIMMING
FOR F30T12 AND F40T12 LAMPS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F40T12 - High Power Factor
86185 2 @ 100% 120 502-A-TC-P-IP✝➑ •• .85 94 .88 0.94 < 1.7 < 20 50/10 A 18 D5
86185 2 @ 20% 120 502-A-TC-P-IP✝➑ •• .68 35 .20 0.57 < 1.7 < 32 50/10 A 18 D5
F30T12 - Corrected Power Factor
86185 2 @ 100% 120 502-A-TC-P-IP➑➂ •• .87 83 .89 1.07 < 1.7 < 20 50/10 A 18 D5
86185 2 @ 20% 120 502-A-TC-P-IP➑➁ •• .58 27 .21 0.77 < 1.9 < 32 50/10 A 18 D5
Requires two circuit interrupting lamp holder
UL component recognized for use with specific Dimming Controls
Power Factor Corrected to <60%
Power Factor Corrected to >60%
2-23
For more information, visit www.gelighting.com
ELECROMAGNETIC
FLUORESCENT BALLASTS
transforming the power of light
2-22
WIRING DIAGRAMS
DIMENSIONS
W
H
L
M
D
Overall Dimensions Mounting Dimensions
Draw # L W H M X
D2 9 1/2 2 3/8 1 1/2 8 57/64 1 11/16
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F40T12 - High Power Factor
86341 2 Rapid 220/50Hz 754-L-TC-P-IP .43 93 .94 1.01 < 1.7 < 20 50/10 A 1 D2
FOR F30T12 AND F40T12 LAMPS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F40T12/WM - High Power Factor
86341 2 Rapid 220/50Hz 754-L-TC-P-IP .37 77 .87 1.13 < 1.9 < 32 60/15 A 1 D2
FOR F40T12/U, F40T12/WM
AND F40T12/WM/U LAMPS
FOR F40T10 LAMPS
GE Lamp Certification Line Input Ballast Min. F/C
Product Line Catalog Current Power Ballast Efficacy Crest THD Start Sound Wiring
Code Qty. Descr. Volts Number NOM (Amps) (Watts) Factor Factor Factor % Temp Rating Diag. Dim.
F40T10 - High Power Factor
86341 2 Rapid 220/50Hz 754-L-TC-P-IP .43 95 .93 0.98 < 1.7 < 20 50/10 A 1 D2
EXPORT
ELECROMAGNETIC
FLUORESCENT BALLASTS
WIRING DIAGRAMS
White
Black
Yell ow Blue
Red
Line BALLAST
Yell ow
Blue
Red
LAMP
LAMP
White
Black
Blue
Red
Line
Red
Use disconnect
lampholder only
BALLAST
LAMP
Blue/White
Yellow Red
Line
LAMP
White
Black
Yellow
Blue
Red
Blue
Blue/White
LAMP
LAMP
BALLAST
BALLAST
Blue
Red
Line
LAMP
White
Black
Blue
Red
Line
Yellow
Red
White
Black
Yel l o w
Blue
Red
Blue
INSULATE EACH YELLOW LEAD
INDIVIDUALLY
BALLAST
LAMP
Blue/White
Yellow
Blue Red
Line
DIMMER
White
White
Black
Black
Yellow
Red
Brown
LAMP
Use disconnect
lampholder only
LAMP
BALLAST
DIAGRAM 1 DIAGRAM 8 DIAGRAM 11
DIAGRAM 15 DIAGRAM 18DIAGRAM 12
DIAGRAM 22 DIAGRAM 28DIAGRAM 21
BALLAST
Line
LAMP
Black
Black
Diagram 21
S
BALLAST
LAMP
White
Black
Blue
S
S
BALLAST Yellow
Blue
Red
Line
LAMP
White
Black
White
Mount lamp within 1/2" of
grounded metal reflector
ELECROMAGNETIC
FLUORESCENT BALLASTS
WIRING DIAGRAMS
transforming the power of light
2-24
WIRING DIAGRAMS
DIAGRAM 34 DIAGRAM 35
Blue
Red
Line White
Black Red
Metal contacts
lamp to fixture
White
BALLAST
BALLAST
Line
White
Black
Red
LAMP
BALLAST
Red
Line
LAMP
White
Black Blue
LAMP
DIAGRAM 29
DIAGRAM 37 DIAGRAM 39DIAGRAM 36
DIAGRAM 42DIAGRAM 40
Blue
Red
Line
White
Black
Brown
Brown BALLAST
LAMP
LAMP
BALLAST Blue
Red
Line
LAMP
White
Black
Blue
Red
BALLAST
Blue
Red
Line
LAMP
White
Blue
Red
Black
Lamps must be mounted within one inch of a grounded
metal reflector, cover of the ballast channel or grounded
metal strip at least one-inch wide over the full length of
the lamp.
Yellow Blue
Red
Line
White
Black
Yellow Blue
Red
BALLAST
LAMP
LAMP
Lamps must be mounted within one inch of a grounded metal
reflector, cover of the ballast channel or grounded metal strip
at least one-inch wide over the full length of the lamp.
BALLAST
LAMP
LAMP
Blue
Line
White
Black Red
3-1
For more information, visit www.gelighting.com
SIGN ILLUMINATING BALLASTS
A COMPLETE RANGE OF SOLUTIONS...
FROM THE NAME YOU TRUST
GE’s high-output ballasts are great for rugged outdoor sign cabinet
applications because they provide reliable low-temperature starting—as
low as -20°F. And all GE sign ballasts offer Class P thermal protection.
Our range of sign ballasts:
• Offers proven reliability
• Is ideal for high-moisture environments
• Supports applications from 1-6 lamps and 2-48 ft.
GE offers the convenience of one-stop shopping not just for sign bal-
lasts but for HID, linear fluorescent, and all your other ballast needs.
GE sign ballasts provide ultra-reliable low-temperature
starting – plus Class P thermal protection.
SIGN ILLUMINATING
BALLASTS
HIGH OUTPUT
SIGN BALLASTS
SIGN ILLUMINATING BALLASTS
transforming the power of light
3-2
APPLICATION
AND OPERATING
INFORMATION
SIGN ILLUMINATING BALLASTS
3-3
For more information, visit www.gelighting.com
Heat
Ballasts generate heat during normal operation. By
design, fluorescent ballasts should operate so that their
maximum hot-spot case temperature does not exceed 90°C
(194°F). Operating at higher temperatures will shorten bal-
last life or may cause the thermal protection circuit to trip.
The temperature the ballast reaches depends on the
temperature of the area surrounding it – plus the heat-
conducting surface touching the ballast. Ballasts should
be installed in a manner that avoids future overheating.
To maintain normal ballast temperature, you should:
1. Mount the ballast against a flat surface of heavy gauge
metal such as the structural part of the sign.
2.Keep the ballast as far away as possible from other
ballasts, lamps or reflective surfaces. (Lamps generate
approximately three-fourths of the heat in a plastic sign).
The ends of the lamps are the hottest part, so you should
mount the ballast as far away from the ends as possible.
3.Paint the inside of the sign with flat white paint.
Moisture Protection
1. Vent the sign as well as possible without allowing
water to enter.
2. Ballasts should be mounted horizontally (except for
weatherproof types). If the ballast must be mounted ver-
tically, allow room for sufficient air circulation.
Wherever possible, mount the ballast in an enclosure
outside the sign by using GE pup tents. You can get pup
tents at no charge when you order the plastic sign bal-
last. Your wholesaler will also have a supply for your con-
venience.
Grounding
The white lead of a 120-volt ballast must be connected
to the neutral or ground side of the power supply. All metal
parts of the sign, as well as the ballast case, must be
grounded either through the conduit which holds the
power supply or by direct connection with a grounding
wire. An underground sign is a potential hazard – and it
can give misleading symptoms when looking for sign faults.
Proper Lamp Life and Starting
In rapid-start installations, proper filament heating is
necessary for reliable starting and normal lamp life. To
ensure that proper heating is taking place, the following
steps are recommended:
1. Lamp leads should be kept as short as possible and with
a minimum of splices.
2. All connections should be soldered.
3. Maintain proper alignment and spacing of lamp holders
to ensure good contact in the sockets.
4. Mount lamps within one inch of grounded metal. This is
one lamp manufacturer's published requirement for
eliable starting.
Flashing
Rapid-start lamps may be flashed without reduction
in lamp life by using ballasts which are specifically
designed for this operation. These ballasts are designed
with slightly higher filament voltages that the conven-
tional ballast to ensure satisfactory lamp life. Instant-
start lamps cannot be flashed.
CAUTION: Use only one flasher contact per ballast.
Light Output vs. Temperature
The light output of a fluorescent lamp varies according
to the mercury vapor pressure inside the lamp. This pressure
is controlled by the coldest spot on the bulb wall. The bal-
last may start the lamp, but the light output can be very
low as the bulb wall temperature is low. Several factors
influence this, including ambient temperatures, wind, type of
enclosure, etc. If maximum light output is critical, consult a
lamp manufacturer for advice.
Lamp Starting Problems
Occasionally a field problem will arise involving improp-
er lamp starting. The usual complaint is that the lamps start
slowly (or not at all). Here are some of the causes:
1. Low line voltage
2. Improper sign grounding
3. Insufficient or no filament voltage
4. Insufficient or no open circuit voltage
5. Dirty lamps during high-humidity operating conditions
6. Lamps improperly inserted in the sockets.
If lamp starting is a problem in your installation, check
the sign grounding, filament voltage (3.4-3.9 volts), and
open circuit voltage. If all are normal, the probable cause is
dirty lamps. The lamps should be washed in clean water,
drip-dried, and reinstalled. If this doesn't solve the prob-
lem, contact your nearest GE representative for further
assistance.
Short Lamp Life
If the lamp has not given proper length of service as
specified by the lamp manufacturer, the following rea-
sons for early failure should be considered:
1. Improper starting due to insufficient filament voltage
2. Frequent starting and short operating periods
3. Improper ballast
4. Improper voltage supply
5. Faulty wiring
6. Defective lamps
7. Lamps improperly inserted in sockets
Early lamp failure will be preceded by a dense blacken-
ing on either or both ends of the lamps. This blackening
will extend three or four inches from the lamp base and
should not be confused with a small dense spot, which is a
mercury deposit that can occur at any time during lamp life.
Dense blackening due to early lamp failure should not be
confused with the gray bands that sometimes appear
toward the end of normal lamp life (about two inches from
either end of the lamp).
APPLICATION AND OPERATING INFORMATION
Total Start Max. Max. Open
GE Product Catalog Lamp Temp Line Input Circuit Wiring Dimen. Weight
Code Number Footage (°F) Cur. Watts Volt. Diagram Chart Ref. (lbs.)
PLASTIC SIGN BALLASTS - HIGH OUTPUT 800mA RS LAMPS - 120 Volts - 60 Hz
TWO LAMP BALLASTS
88921 USB-0412-12-IP 4´ min. - 12´ max. -20 1.35 160 500 1a, 2a 1 8
FOUR LAMP BALLASTS
88931 USB-0816-14-IP 8´ min. - 16´ max. -20 1.90 220 590 4a, 6a, 9, 1b 2 12
88936 USB-1024-14-IP 10´ min. - 24´ max. -20 2.70 325 720 4a, 6a, 9, 1b 3 14
88934 USB-1632-24-IP 16´ min. - 32´ max. -20 3.50 420 950 4a, 6a, 9 4 16
SIX LAMP BALLASTS
88939 USB-2036-46-IP 20´ min. - 36´ max. -20 4.00 480 720 5a, 7, 7a 4 18
88940 USB-2048-46-IP 20´ min. - 48´ max. -20 5.00 600 720 5a, 7, 7a 4 18
Diagrams Notes:
Note 1: When operating a two-lamp ballast on one lamp insulate each yellow lead.
Note 2: When operating a three-lamp ballast on two lamps insulate each yellow and
blue/white lead.
Note 3: When operating a four-lamp ballast on three lamps insulate each yellow
blue/white, and brown lead.
STANDARD HIGH OUTPUT
SIGN BALLASTS
HIGH OUTPUT SIGN BALLASTS
DIMENSIONS
DIMENSION CHART
Ref. # A B C D E
110CM\nv˝ 11VB\nv˝ 11>\nv˝ 1C\v˝ 3C\zn˝
210CM\nv˝ 11VB\nv˝ 11>\nv˝ 2VC\nv˝ 3C\zn˝
313C\zn˝ 14B\zn˝ 13C\v˝ 2VC\nv˝ 3 C\zn˝
415>\zn˝ 16ZZ\zn˝ 16Z\,˝ 2VC\nv˝ 3C\zn˝
513>\zn˝ 16ZZ\zn˝ 16Z\,˝ 2 VC\nv˝ 3 C\zn˝
See page 4-4 for Lead Lengths
Total Start Max. Max. Open
GE Product Catalog Lamp Temp Line Input Circuit Wiring Dimen. Weight
Code Number Footage (°F) Cur. Watts Volt. Diagram Chart Ref. (lbs.)
MAX-3 HIGH OUTPUT SIGN BALLASTS 800mA RS LAMPS - 120 Volts - 60 Hz
ONE TO SIX LAMP BALLASTS
88918 USB-0218-16-IP 2´ min. - 18´ max. -20° 2.00 240 625 3, 4, 5, 6, 7, 8 3 15
88920 USB-1232-16-IP 12´ min. - 32´ max. -20° 3.50 410 970 3, 4, 5, 6, 7, 8 3 16
88919 USB-1048-16-IP 10´ min. - 48´ max. -20° 4.80 570 800 1, 2, 3, 4, 7, 8 5 18
WHITE
BLACK
BLUE
BLUE
RED
RED
YELLOW
YELLOW
LINE
BALLAST
LAMP
BLACK
BLUE
BLUE
BROWN
BROWN
YELLOW
YELLOW
RED
RED
BLUE/WHITE
BLUE/WHITE
LINE
BALLAST
LAMP
WHITE
BLACK
YELLOW
YELLOW
RED
RED
BLUE
BLUE
LINE BALLAST
LAMP 1
LAMP 2
MOUNT LAMPS WITHIN 1˝ OF
GROUNDED METAL REFLECTOR
WHITE
BLACK
BROWN
BROWN
YELLOW
YELLOW
LINE BLUE
BLUE
BLUE / WH
BLUE / WH
RED
RED
BALLAST
LAMP 4
LAMP 3
LAMP 1
MOUNT LAMPS WITHIN 1˝ OF
GROUNDED METAL REFLECTOR
LAMP 2
WHITE
BLACK
BROWN
BROWN
BLUE / WH
BLUE / WH
YELLOW
YELLOW
LINE BLUE
BLUE
ORANGE / BLK
ORANGE / BLK
ORANGE
ORANGE
RED
RED
BALLAST
LAMP 1
LAMP 2
LAMP 4
MOUNT LAMPS WITHIN 1˝ OF
GROUNDED METAL REFLECTOR
LAMP 3
LAMP 6
LAMP 5
BLACK
WHITE
YELLOW
YELLOW
BROWN
BROWN
RED
RED
BLUE / WH
BLUE / WH
BLUE
BLUE
LINE
BALLAST
LAMP 2
LAMP 3
INDIVIDUALLY CAP
THE YELLOW LEADS
LAMP 1
DIAGRAM 1 DIAGRAM 1A DIAGRAM 1B
DIAGRAM 2 DIAGRAM 2A DIAGRAM 3
DIAGRAM 4 DIAGRAM 4A DIAGRAM 5
DIAGRAM 5A DIAGRAM 6 DIAGRAM 6A
3-5
For more information, visit www.gelighting.com
SIGN ILLUMINATING BALLASTS
transforming the power of light
3-4
SIGN ILLUMINATING BALLASTS
WIRING DIAGRAMS
LEAD LENGTH &
BALLAST FOOTAGE
PLASTIC SIGN BALLASTS
LEAD LENGTHS (INCHES)
GE Product Catalog Orange Blue Red
Code Number White Black Blues Reds Yellows Browns Oranges Blacks Whites Whites
PLASTIC SIGN BALLASTS - HIGH OUTPUT 800mA RS LAMPS - 120 Volts - 60 Hz
TWO LAMP BALLASTS
88921 USB-0412-12-IP 24 24 38 38 48
FOUR LAMP BALLASTS
88931 USB-0816-14-IP 36 24 65 40 39 56 48
88936 USB-1024-14-IP 24 24 79 48 75 83 57
88934 USB-1632-24-IP 24 24 80 54 60 80 72
SIX LAMP BALLASTS
88939 USB-2036-46-IP 24 24 50 80 70 38 50 50 38
88940 USB-2048-46-IP 24 24 80 80 70 50 50 50 50
MAX-3 HIGH OUTPUT SIGN BALLASTS 800mA RS LAMPS - 120 Volts - 60 Hz
ONE TO SIX LAMP BALLASTS
88918 USB-0218-16-IP 24 24 60 60 60 60 60 60 60
88920 USB-1232-16-IP 24 24 80 60 60 80 60 60 72
88919 USB-1048-16-IP 24 24 80 80 70 50 60 60 50
Note: Maximum volts above ground, any lead 590 volts.
SIGN BALLAST FOOTAGE
No. of
Lamps
Per
Ballast
4-6
Fluorescent Sign Ballast Matrix
TOTAL LAMP FOOTAGE REQUIRED
24 681012 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
1-2 88921, USB-0412-12-IP
88931, USB-0816-14-IP
1-4 88936, USB-1024-14-IP
2-4 88934, USB-1632-24-IP
88939, USB-2036-46-IP
88940, USB-2048-46-IP
88918, USB-0218-16-IP
1-6 88920, USB-1232-16-IP
88919, USB-1048-16-IP
WIRING DIAGRAMS
SIGN ILLUMINATING BALLASTS
transforming the power of light
3-6
WIRING DIAGRAMS
BLACK
WHITE
BROWN
BROWN
BLUE / WH
BLUE / WH
YELLOW
YELLOW
LINE BLUE
BLUE
ORANGE / BLK
ORANGE / BLK
ORANGE
ORANGE
RED
RED
BALLAST
INDIVIDUALLY CAP
THE YELLOW LEADS
LAMP 6
LAMP 2
LAMP 4
LAMP 5
LAMP 1
DIAGRAM 7 DIAGRAM 7A DIAGRAM 8
DIAGRAM 9
WIRING DIAGRAMS
Our newest compact fluorescent models offer installer-friendly
universal input voltage.
4-1
For more information, visit www.gelighting.com
COMPACT
FLUORESCENT BALLASTS
A
COMPLETE RANGE OF SOLUTIONS
FROM THE NAME YOU TRUST
GE offers a full range of magnetic and electronic compact fluores-
cent ballasts. Our magnetic models come in a variety of shapes and
sizes, from core and coils to High Power Factor potted ballasts
with bottom exit leads and mounting studs for all downlighting
applications.
Our newest electronic models offer installer-friendly universal
input voltage, which reduces your inventory and ensures that you
have the right voltage ballast every time. These models feature a
low profile case that fits in any fixture. And their metal housing
construction meets all plenum codes and delivers maximum heat
transfer to extend ballast life.
COMPACT
FLUORESCENT
BALLASTS
COMPACT
FLUORESCENT BALLASTS
transforming the power of light
4-2 4-3
For more information, visit www.gelighting.com
COMPACT
FLUORESCENT BALLASTS
PRODUCT
OVERVIEW
UNDERSTANDING
CFL TECHNOLOGY
PRODUCT OVERVIEW
Electronic Compact Fluorescent Ballasts
Electronic compact fluorescent ballasts from GE fea-
ture installer-friendly universal input voltage (108 to 305
Volts) and metal case designs for compliance with all
plenum and construction code requirements. They also
offer an end-of-life shutdown circuit with auto-reset
that meets ANSI/NEMA requirements a feature that
eliminates lamp/socket damage while allowing you to
replace failed lamps after shutdown without turning off
the power.
Our universal voltage compact fluorescent ballasts
offer both one- and two-lamp operationand they're
ideal for a wide variety of downlight and surface
mount applications for atriums, hotel corridors,
offices, and outdoors. All models operate multiple
lamp types for added versatility in many different
applications.
These ballasts are designed and manufactured for
long life. Lamps can be mounted in close proximity to
these ballasts because they have no temperature-critical
components near the can sides. And their circuit board
potting enhances reliability by lowering case tempera-
tures.
All universal voltage compact fluorescent ballasts
incorporate programmed rapid start (PRS) technology
that increases lamp life for those frequently switched
applications where occupancy sensors are used. PRS is
recommended by all lamp manufacturers.
For the Canadian market, we have new 347 Volt com-
pact fluorescent models. These also offer outstanding relia-
bility and lamp performance. These 347 Volt models are
available for one- and two-lamp operation for lamps rang-
ing from 13 to 70 watts.
Magnetic Compact Fluorescent Ballasts
GE offers a complete line of magnetic compact fluo-
rescent ballasts, ranging from 5-40 watts (10-38 watts
for 2D lamps). Both core & coil and F-Can models are
available in a variety of configurations that include side
exit (SE), bottom exit (BE) and bottom exit studs (BES).
UNDERSTANDING CFL TECHNOLOGY
Compact fluorescent (CFL) lamps are single-ended
and plug into sockets. They're sometimes referred to as
“single-based” or “single-ended” fluorescent lamps.
Lamp Shapes
Today's CFL lamps come in these basic shapes: twin
tube, quad, triple, multi and circular. Each of these shapes
has its own subset of sizes. For example, the twin tube
may range from 4" long (5 watt) to 22" long (40 watt).
Pins and Starters
CFL lamps feature either two pins or four pins.
Those with two pins have starters built into their bases,
and they require a magnetic preheat ballast. The two-
pin CFL lamps are available in wattages from 5-28.
Four-pin lamps are traditionally powered by elec-
tronic ballasts. These lamps do not have an internal
starter, so the other filament terminals (pins) are made
accessible for external connection to the ballasts. Note:
GE offers both magnetic and electronic ballasts for the
four-pin 32 and 26 watt lamps and all four-pin Long
Twin T5 lamps.
Lamp Bases
There are a variety of lamp bases used with today's
CFL lamps. This provides a safeguard to make sure that
the proper lamp/ballast combination is installed. The
lamp base style is part of the ANSI/NEMA designation.
In this catalog, GE CFL ballasts are classified according
to lamp type. Icons representing each lamp type provide a
quick visual reference. Within each classification, the
lamps and their appropriate ballasts can be found by
referring to the generic NEMA lamp descriptions.
Lamp Designation
There are two different industry-recognized
nomenclatures for identifying CFL lamps: ANSI Lamp
Designations and NEMA Lamp Designations.
Here are examples of each:
Installer-friendly options for compact fluorescent lamps.
13W 7T4 TGX23 PH
Lamp
Wattage
Lamp
Length
Lamp
Diameter
1/8"
Twin (T)
Quad (Q)
Multi (M)
2D (S)
Base Starting:
PH - Preheat
RS - Rapid
Start
CFT 13W GX23
Twin (T)
Quad (Q)
Multi (M)
2D (S)
Lamp
Wattage
Base
Twin, 2-Pin
5w – 13w
Long Twin T5, 4-Pin
5w – 80w
2-Pin 4-Pin
Quad 9w – 27w
Square (2D)
10w – 55w
Multiple, 4-Pin
(GE & OSI)
18w – 70w
Multiple, 4-Pin
(Philips)
18w – 42w
OR
OR
OR
T5 Circular
22w - 55w
Industry
Single
or Twin
Double
or Quad
Multiple
Multiple
Long Twin
T5
Square
Circline
Watts
5, 7, 9, 13
9, 13, 18,
20, 26, 27
13,18, 26,
32, 42
42,57,70
18, 24/27,
36/39, 40
50,80
10, 16, 21,
28, 38,55
22, 40, 55
GE
Low watt
Biax
Double
Biax
Biax T/E
Biax Q/E
High
Lumen
Biax
2D
__
OSI
Dulux S,
S/E
Dulux D,
D/E
Dulux T
T/E, T/E/IN
Dulux T/E/IN
Dulux L, F
__
Pentron
Philips
PL-S
PL-C
PL-T
PL-T
PL-L
__
Silhouette
NEMA Designation
ANSI Designation
Both lamp designations refer to lamp wattage, shape,
and base type. Since the NEMA designation is shorter, it
will probably be the nomenclature of choice in the future.
All of the major lamp companies have trade names for
various CFL lamp types, such as GE’s “Biax” and “2D”
lamps, OSI’s “Dulux,” and Philips’ “PL.” These names
have become more widely used than either of the indus-
try designations.
4-5
For more information, visit www.gelighting.com
COMPACT
FLUORESCENT BALLASTS
COMPACT
FLUORESCENT BALLASTS
SPECIFICATIONS
transforming the power of light
4-4
1. Ballast shall be Programmed Rapid Start.
2. Ballast shall incorporate lamp shutdown circuitry
for end of lamp life protection.
3. Ballast shall allow for re-lamping without the
need to cycle power.
4. Ballasts shall operate from 50/60 Hz input
source of 120, 277, or 347 Volts with no dam-
age to the ballasts.
4a. Ballasts shall operate from 50/60 Hz input
source of 108-305 Volts with no damage to the
ballasts for High Performance (HP) models.
5. Ballast shall be of metal can construction to
meet all plenum requirements and to eliminate
the need for extra grounding wires.
6. Ballasts shall be a high frequency electronic
type, and operate lamps at a frequency above
50 kHz to minimize interference with infrared
control systems.
7. Lamp Current Crest Factor (ratio of peak to RMS
current) shall be 1.7 or less in accordance with
lamp manufacturer recommendation and ANSI
C82.11-1993.
8. Ballasts shall tolerate operation in ambient tem-
peratures up to 140°F (55°C) without damage.
9. Ballasts shall have a maximum case temperature
test point of 75°C printed on the label for easy
fixture testing and troubleshooting.
10. Ballast shall have a maximum case temperature
rise of 15°C.
11. Ballasts shall comply with FCC Part 18 Non-
Consumer Equipment for EMI (power line con-
ducted) and RFI (Radiated).
12. Ballasts shall provide transient immunity as rec-
ommended by ANSI C62.41-1991.
13. Ballasts shall operate lamps with no visible flick-
er (< 3% flicker index).
14. Ballasts shall tolerate sustained open circuit and
short circuit output conditions without damage.
15. Ballasts shall be Underwriters Laboratory (UL
935) listed, Class P, Type 1 Outdoor, and CSA
certified where applicable.
16. Input current Total Harmonic Distortion shall not
exceed 10% for the primary lamp.
17. Ballasts shall have a Power Factor greater than
.98 for the primary lamp.
18. The ballasts shall not have any PCBs.
19. The manufacturer shall provide written warranty
against defects in material or workmanship,
including replacement, for five years from date
of manufacture.
20. Manufacturer shall have been manufacturing
electronic ballasts for at least fifteen years.
21. Ballast shall be manufactured in an ISO 9001
Certified Facility.
22. GE model_________________________ (or
approved equal).
TYPICAL SPECIFICATIONS FOR ELECTRONIC
COMPACT FLUORESCENT BALLASTS
UNDERSTANDING PART NUMBERS
Example: C213UNVBES000C*
Ballast Type: C
Lamp Quantity: 2
Lamp Type: 13W Quad, 4 Pin (CFQ13W/G24q)
Voltage: UNV 120 to 277 Volts
BES: Bottom exit connection, studs
000C: ColorBlack
C: Packaging container style—Carton Pack
*Exception is C2642, which does not distinguish
number of lamps. See catalog.
4XXX XX P XXX XXX X
1 – 120V
2 – 277V
3 – 347V
F1 – Frame
F2 – Fr. w/feet
H2 – Cover/Fr.
Odd = NPF
Even = HPF
No suffix – Side Exit
BE – Bottom Exit
BES – Bottom Exit
with Studs
C – Carton
T– Tray Pack
Thermally
Protected
Color:
001 – White
000 – Black
CXXX X XXX XXX XXX X
# of Lamps
Lamp
Wattage*
No suffix=P
P=Programmed
Rapid Start
I=Instant Start
SE – Side Exit
BE – Bottom Exit
BES – Bottom
Exit/Studs
HP-B – Low Profile
RH – Reduced
Harmonics
T = Tray Pack
C – Carton Pack
I – Individual
120V, 277V
347V, UNV
(120-277)
Colors
000 – Black
001 – White
CXXX XX XXX XXX XXX X
# of lamps SR-Series,
Rapid Start
R-Rapid Start
Lamp
Wattage
No suffix or SE –
Side Exit
BE – Bottom Exit
BES – Bottom Exit
with Studs
UNV or 347V Color: 001-White
000-Black
C-Carton
T-Tray Pack
I-Individual
UNDERSTANDING
PART NUMBERS
Magnetic
Our part number nomenclature for magnetic
ballasts is shown below:
Example: 4123PBES000T
Ballast for CFL Lamps: Indicated by “4” prefix
Voltage: 120V
Lamp Type: 26W Quad Lamp (refer to catalog
for wattage)
Power Factor: Normal
Encased and Potted: Indicated by absence of
F1, F2, or H2
P: Thermally protected
BES: Bottom exit leads with studs
000: ColorBlack
T: Packaging container style Tray Pack
These ballasts are available for a wide variety of
applications with lamps, voltages, mounting
configurations, and performance characteristics. For
more detailed information, just identify the lamps
to be ballasted and work forward to determine the
ballast part number.
Electronic
Our nomenclature for electronic CFL ballasts
follows the system already in place for other elec-
tronic ballasts. The exceptions are that the model
number prefix for compact fluorescent is a C rather
than a Band the suffixes for the mounting config-
uration will be the same as those used for magnetic
products (BE and BES). If you don't see these suffix-
es, the ballast has traditional side exit leads.
Example: Electronic C240PUNVHP-B
Ballast Type: C — CFL Electronic Ballast
Lamp Qty: 2
Lamp Type: 40W TT5, 4 Pin (FT40W/2611)
P: Programmed Rapid Start
Voltage: UNV 120 to 277 Volts
HP-B: High Performance <10%; low profile can
000: ColorBlack
C: Packaging container style—Carton Pack
4-7
For more information, visit www.gelighting.com
MAGNETIC COMPACT
FLUORESCENT BALLASTS
MAGNETIC COMPACT
FLUORESCENT BALLASTS
transforming the power of light
4-6
TWIN LAMPS5 WATTS
TWIN LAMPS7 WATTS
DIMENSIONS
Twin, 2-Pin
Lamp Type
5 Watts
CFT5W/G23
7 Watts
CFT7W/G23
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
87634 M 1 277 4205F2P ■★ 11 0.08 0.19 1.00 0°F Normal <10% PH B2 1
All ballasts are UL listed, CSA approved and designated Class P (thermally protected).
REFERENCE DRAWING FOR A1, A2, B1, B2
AB
C
E
D
Lead Lengths: 10˝
Dwg. A B C D E
B2 1.94” 1.64” 1.97” 2.38” 2.81”
QUICK
REFERENCE
Nominal lamp
watts and
configuration
QUICK
REFERENCE
Nominal lamp
watts and
configuration
TWIN LAMPS
5-13 WATTS
TWIN & QUAD LAMPS
13- 26 WATTS
TWIN & QUAD LAMPS13 WATTS - U.S. LAMPS
OR
Twin or
Quad, 2-Pin
U.S. type
lamp
Lamp Type
13 Watts
CFT13W/GX2 OR
CFQ13W/GX23
Non-thermally protected models available.
PH = Preheat
F1 indicates an open core & coil unit with no mounting feet.
F2 indicates an open core & coil unit with mounting feet.
H2 indicates clamped & covered core & coil with mounting feet.
F1R - Coil enclosed with plastic covers/no mounting feet.
F2R - Coil enclosed with plastic covers/with mounting feet.
Standard cases offer side lead configuration.Add “BE” suffix for Bottom Exit design or “BES” for Bottom Exit
Studs design.
Not approved for use in hazardous locations.
{
REFERENCE DRAWING FOR C3, C4, C5
15/16"
AF
B
D
E
C
Lead Lengths: Side –12˝
BE/BES
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
87634 M 1 277 4205F2P ■★ 12 0.08 0.19 0.95 0°F Normal <10% PH B2 1
TWIN & QUAD LAMPS9 & 10 WATTS
OR
Twin or
Quad, 2-Pin
Lamp Type
9 Watts
CFT9W/G23 OR
CFQ9W/G23
10 Watts
CFQ10W/G24d
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
87634 M 1 277 4205F2P■★ 14 0.11 0.18 0.95 0°F Normal <10% PH B2 1
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
87655 87655 87655 M 2 277 4214PBES26 0.09 0.09 0.85 32°F High <20% PH C4 9
Dwg. A B C D E F
C4 2.34” 1.53” 5.20” 6.00” 6.59” 0.31”
TWIN, QUAD AND MULTIPLE LAMPS13 WATTS
OR
Quad or
Multiple, 4-Pin
Lamp Type
13 Watts
CFQ13W/G24q OR
CFM13W/GX24q
13W: Twin T4, 4-Pin
18W: Twin T5, 4-Pin
TWIN, QUAD AND MULTIPLE LAMPS18 WATTS
OR
Quad or
Multiple, 4-Pin
Lamp Type
18 Watts
CFQ18W/G24q OR
CFM18W/GX24q
Lamp Type
13 Watts
CFT13W/2GX7
18 Watts
FT18W/2G11RS
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
80673 80669 80671 E 1 120 C213UNV
18 0.15 —— 1.00 0°F High <10% PRS C10 18
80673 80669 80671 E 2 120 C213UNV
32 0.27 —— 0.98 0°F High <10% PRS C10 19
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
80679 80675 80677 E 1 120 C218UNV22 0.19 —— 1.00 0°F High <10% PRS C10 18
80679 80675 80677 E 2 120 C218UNV40 0.34 —— 0.98 0°F High <10% PRS C10 19
DIMENSIONS
All ballasts are UL listed, CSA approved and designated Class P (thermally protected).
REFERENCE DRAWING FOR C3, C4, C5
15/16"
AF
B
D
E
C
QUAD AND TRIPLE LAMPS26 WATTS
QUAD AND MULTIPLE LAMPS26 WATTS
Lamp Type
26 Watts
CFQ26W/G24d
26 Watts
CFQ26W/G24q OR
CFM26W/GX24q
Lead Lengths: Side
• Black/White–11˝
• Red/Blue–12˝
BE/BES
OR
Quad or
Multiple, 4-Pin
REFERENCE DRAWING FOR C10
D
F
E
A
G
C
B
REFERENCE DRAWING FOR C11
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
87700 87700 87700 M 2 277 4226P62 0.22 0.34 0.90 32°F High <20% PH C4 8
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
80689 80685 80687 E 1 120 C2642UNV28 0.25 —— 1.02 0°F High <10% PRS C10 18
80689 80685 80687 E 2 120 C2642UNV56 0.49 —— 0.98 0°F High <10% PRS C10 19
47509 47503 47506 E 2 120 C242UNV56 0.46 —— 1.02 0°F High <10% PRS C11 19
PRS = Programmed Rapid Start; RS = Rapid Start
F1 indicates an open core & coil unit with no mounting feet.
F2 indicates an open core & coil unit with mounting feet.
Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or
“BES” for Bottom Exit connectors with 2˝ O.C. screw studs.
Standard cases offer side lead configuration. Add “BE” suffix for Bottom Exit design or “BES” for Bottom Exit Studs design.
Dwg. A B C D E F
C4 2.34” 1.53” 5.20” 6.00” 6.59” 0.31”
Dwg. A B C D E F G
C10 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00”
C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.55” 1.00”
Leadless-Poke-in wire connection
2D LAMPS
10-21 WATTS
4-9
For more information, visit www.gelighting.com
ELECTRONIC COMPACT
FLUORESCENT BALLASTS
ELECTRONIC COMPACT
FLUORESCENT BALLASTS
MULTIPLE LAMPS
32-70 WATTS
transforming the power of light
4-8
DIMENSIONS
MULTIPLE LAMPS32, 42, 57 & 70 WATTS
All ballasts are UL listed, CSA approved and designated Class P (thermally protected), Type HL.
Lamp Type
32 WATTS
CFM32W/GX24q
Multiple, 4-Pin
Lamp Type
42 Watts
CFM42W/GX24q
Multiple, 4-Pin
Lamp Type
57 Watts
CFM57W/GX24q
Multiple, 4-Pin
Lamp Type
70 Watts
CFM70W/GX24q
Multiple, 4-Pin
REFERENCE DRAWING FOR C10
D
F
E
A
G
C
B
Dwg. A B C D E F G
C10 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00”
C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.55” 1.00”
Leadless-Poke-in wire connection
REFERENCE DRAWING FOR C11
DIMENSIONS
All ballasts are UL listed, CSA approved and designated Class P (thermally protected), Type HL.
REFERENCE DRAWING FOR C10
D
F
E
A
G
C
B
Dwg. A B C D E F G
C10 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00”
C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.55” 1.00”
Leadless-Poke-in wire connection
2D LAMPS10 WATTS
Lamp Type
16 Watts
CFS16W/GR8
16 Watts
CFS16W/GR10q
2D, 2-Pin or
2D, 4-Pin
2D LAMPS16 WATTS
2D LAMPS21 WATTS
Lamp Type
10 Watts
CFS10W/GR10q
2D, 4-Pin
Lamp Type
21 Watts
CFS21W/GR10q
2D, 4-Pin
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
80689 80685 80687 E 1 120 C2642UNV36 0.32 —— 1.00 0°F High <10% PRS C10 18
80689 80685 80687 E 1 120 C2642UNV48 0.42 —— 0.98 0°F High <10% PRS C10 18
47509 47503 47506 E 1 120 C242UNV45 0.38 —— 1.00 0°F High <10% PRS C11 19
47509 47503 47506 E 2 120 C242UNV91 0.76 —— 0.98 0°F High <10% PRS C11 19
47509 47503 47506 E 1 120 C242UNV58 0.48 —— 1.00 0°F High <10% PRS C11 19
47509 47503 47506 E 1 120 C242UNV 73 0.61 —— 1.00 0°F High <10% PRS C11 19
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
80673 80669 80671 E 1 120 C213UNV
15 0.12 —— 1.02 0°F High <12% PRS C10 18a
80673 80669 80671 E 2 120 C213UNV
26 0.22 —— 1.02 0°F High <12% PRS C10 19a
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
80673 80669 80671 E 1 120 C213UNV19 0.15 —— 0.95 0°F High <10% PRS C10 18a
80673 80669 80671 E 2 120 C213UNV33 0.28 —— 0.95 0°F High <10% PRS C10 19a
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
80679 80675 80677 E 1 120 C218UNV24 0.18 —— 0.98 0°F High <10% PRS C10 18a
80679 80675 80677 E 2 120 C218UNV43 0.37 —— 0.95 0°F High <10% PRS C10 19a
QUICK
REFERENCE
Nominal lamp
watts and
configuration
QUICK
REFERENCE
Nominal lamp
watts and
configuration
RS = Rapid Start; PRS = Programmed Rapid Start
Standard cases offer side lead configuration. Add “BE” suffix for Bottom Exit design or “BES” for Bottom Exit Studs design.
Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or
“BES” for Bottom Exit connectors with 2˝ O.C. screw studs.
Starter required: use COP-40 or FS-4 type fluorescent starter.
RS = Rapid Start; PRS = Programmed Rapid Start
Standard cases offer side lead configuration. Add “BE” suffix for Bottom Exit design or “BES” for Bottom Exit Studs design.
Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or
“BES” for Bottom Exit connectors with 2˝ O.C. screw studs.
4-11
For more information, visit www.gelighting.com
ELECTRONIC COMPACT
FLUORESCENT BALLASTS
MAGNETIC AND ELECTRONIC COMPACT
FLUORESCENT BALLASTS
2D LAMPS
28-38 WATTS
transforming the power of light
4-10
DIMENSIONS
All ballasts are UL listed, CSA approved and designated Class P (thermally protected), Type HL.
DIMENSIONS
All ballasts are UL listed, CSA approved and designated Class P (thermally protected), Type HL.
Dwg. A B C D E F G
C3 2.14” 1.56” 3.50” 4.31” 4.75” 0.22”
C4 2.34” 1.53” 5.20” 6.00” 6.59” 0.31”
C5 1.88” 1.47” 5.13” 6.00” 6.44” 0.25”
C10 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00”
2D LAMPS28 WATTS
Lamp Type
28 Watts
CFS28W/GR8
28 Watts
CFS28W/GR10q
2D, 2-Pin or
2D, 4-Pin
REFERENCE DRAWING FOR C3, C4, C5
15/16"
AF
B
D
E
C
Lead Lengths: Side –12˝
BE/BES
2D LAMPS38 WATTS
Lamp Type
38 Watts
CFS38W/GR10q
2D, 4-Pin
REFERENCE DRAWING FOR C10
D
F
E
A
G
C
B
Leadless-Poke-in wire connection
T5 CIRCULAR
LAMPS
22-40 WATTS
T5 CIRCULAR LAMPS22 & 40 WATTS
Lamp Type
22 Watts
FC9T5-22W
T5 CIRCULAR
Lamp Type
40 Watts
FC12T5-40W
T5 CIRCULAR
Lamp Type
22 & 40
Watts
FC9T5-22W &
FC12T5-40W
T5 CIRCULAR
REFERENCE DRAWING FOR C10
D
F
E
A
G
C
B
Dwg. A B C D E F G
C10 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00”
C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.55” 1.00”
Leadless-Poke-in wire connection
REFERENCE DRAWING FOR C11
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
87700 87700 87700 M 2 277 4226PBES66 0.23 0.34 0.93 25°F High <20% PH C4 7a
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
87623 87623 M 2 120 4150P84 0.72 — 0.80 0°F High <10% PRS C10 18a
120 or
80689 80685 80687 E 1 277 or C2642UNV33 0.13 — 0.80 0°F High <10% PRS C10 18a
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
80689 80685 80687 E 1 120 C2642UNV25 0.22 —— 1.00 0°F High <10% PRS C10 28
277 0.10
47509 47503 47506 E 2 120 C242UNV50 0.42 —— 1.05 0°F High <10% PRS C11 23
277 0.19
80689 80685 80687 E 1 120 C2642UNV42 0.37 —— 0.98 0°F High <10% PRS C10 28
277 0.16
47509 47506 E 2 120 C242UNV80 0.65 —— 0.98 0°F High <10% PRS C11 2347503 277 79 0.29
47509 47503 47506 E 2 120 C242UNV66 0.54 —— 0.98 0°F High <10% PRS C11 23
277 64 0.24
QUICK
REFERENCE
Nominal lamp
watts and
configuration
RS = Rapid Start; PRS = Programmed Rapid Start
Standard cases offer side lead configuration. Add “BE” suffix for Bottom Exit design or “BES” for Bottom Exit Studs design.
Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or
“BES” for Bottom Exit connectors with 2˝ O.C. screw studs.
QUICK
REFERENCE
Nominal lamp
watts and
configuration
Starter required: use COP-40 or FS-4 type fluorescent starter.
Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or
“BES” for Bottom Exit connectors with 2˝ O.C. screw studs.
T5 LONG TWIN
36-39 WATTS
4-13
For more information, visit www.gelighting.com
MAGNETIC AND ELECTRONIC COMPACT
FLUORESCENT BALLASTS
MAGNETIC AND ELECTRONIC COMPACT
FLUORESCENT BALLASTS
T5 LONG TWIN
24-27 WATTS
transforming the power of light
4-12
LONG TWIN T5 BALLASTS24/27 WATTS
(BIAX, DULUX L AND PLL)
Lamp Type
24/27 Watts
FT24W/2G11/RS
24/27 Watts
FT24W/2G10
Long Twin
T5, 4-Pin or
Long Twin
T5, 4-Pin
RS = Rapid Start; PRS = Programmed Rapid Start
Standard cases offer side lead configuration.
Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or
“BES” for Bottom Exit connectors with 2˝ O.C. screw studs.
Not approved for use in hazardous locations.
DIMENSIONS
All ballasts are UL listed, CSA approved and designated Class P (thermally protected).
DIMENSIONS
All ballasts are UL listed, CSA approved and designated Class P (thermally protected).
REFERENCE DRAWING FOR C10
D
F
E
A
G
C
B
Dwg. A B C D E F G
C10 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00”
C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.55” 1.00”
Leadless-Poke-in wire connection
REFERENCE DRAWING FOR C11
REFERENCE DRAWING FOR -C
Dwg. L W H M X
-C 14.25” 1.18” 1.00” 13.75” ---
LONG TWIN T5 BALLASTS36/39 WATTS
(BIAX, DULUX L AND PLL)
Lamp Type
36/39 Watts
FT36W/2G11/RS
36/39 Watts
FT36W/2G10
Long Twin
T5, 4-Pin
RS = Rapid Start; PRS = Programmed Rapid Start
Standard cases offer side lead configuration.
New auto reset shutdown circuit
Add following suffix for complete catalog # “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or
“BES” for Bottom Exit connectors with 2˝ O.C. screw studs.
Not approved for use in hazardous locations.
REFERENCE DRAWING FOR C6
Dwg. A B C D E F
C6 2.40” 1.55” 8.31” 8.89” 9.50” 1.19”
B
C
AF
E
D
5/16 "
111/16"
Lead Lengths:
Magnetic
Models 4145P, 4245P,
4146P, 4246P
Black/White-11˝
Red/Blue/Yellow -16˝
Electronic
Black/White-24˝
Red/Blue-30˝
Yellow - 4
Magnetic
(All other)
Black/White- 20˝
Red/Blue/Yellow -
30˝
REFERENCE DRAWING FOR C11
Dwg. A B C D E F G
C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.56” 1.00”
Leadless-Poke-in wire connection
REFERENCE DRAWING FOR -D
Dwg. L W H M X
-D 16.88” 1.16” 1.00” 16.28” ---
REFERENCE DRAWING FOR -C
Dwg. L W H M X
-C 14.25” 1.18” 1.00” 13.75” ---
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
47535 —
E1 120 B224PUNV-C 27 0.23 —— 1.05 0°F High <10% PRS -C 27
277 0.10 <15%
47535 —
E2 120 B224PUNV-C 52 0.43 —— 1.00 0°F High <10% PRS -C 27
277 51 0,18
80689 80685 80687 E 1 120 C2642UNV30 0.26 —— 0.90 0°F High <10% PRS C10 21
277 0.11
80689 80685 80687 E 2 120 C2642UNV52 0.45 —— 0.85 0°F High <10% PRS C10 20
277 0.20
47509 47503 47506 E 2 120 C242UNV51 0.43 —— 1.02 0°F High <10% PRS C11 20
277 50 0.19
47535 —
E1 120 B224PUNV-C 24 0.20 —— 1.05 0°F High <10% PRS -C 27
277 0.09 <15%
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
87623 M 2 120 4150P88 0.76 —— 0.90 50°F High <20% RS C6 5
80152 —
E1 120 B140R120HP 38 0.32 —— 0.90 50°F High <10% RS C6 11
80153 —
E1 277 B140R277HP 38 0.13 —— 0.94 50°F High <10% RS C6 11
80154 —
E1 120 B240R120HP 46 0.40 —— 1.00 50°F High <10% RS C6 13
80155 —
E1 277 B240R277HP 46 0.17 —— 1.00 50°F High <10% RS C6 13
80154 —
E2 120 B240R120HP 75 0.62 —— 0.89 50°F High <10% RS C6 13
80155 —
E2 277 B240R277HP 75 0.27 —— 0.89 50°F High <10% RS C6 13
47535 —
E1 120 B224PUNV-C
36 0.30 —— 0.95 0°F High <10% PRS -C 27
277 0.13
47540 —
E1 120 B239PUNV-D
38 0.32 —— 1.02 0°F High <10% PRS -D 27
277 0.15
47540 —
E2 120 B239PUNV-D
71 0.59 —— 0.97 0°F High <10% PRS -D 27
277 70 0.26
80156 —
E3 120 B340R120HP 106 0.89 —— 0.90 50°F High <10% RS C6 15
89219 —
E2 120 B240R120RH 69 0.58 —— 0.90 50°F High <20% RS C6 13
80157 —
E3 277 B340R277HP 106 0.39 —— 0.90 50°F High <10% RS C6 15
47509 47503 47506 E 2 120 C242UNV
68 0.57 —— 0.90 0°F High <10% PRS C11 20
277 67 0.25
47509 47503 47506 E 2 120 C242UNV
68 0.57 —— 0.90 0°F High <10% PRS C11 20
277 67 0.25
QUICK
REFERENCE
Nominal lamp
watts and
configuration
QUICK
REFERENCE
Nominal lamp
watts and
configuration
WIRING DIAGRAMS
4-15
For more information, visit www.gelighting.com
ELECTRONIC COMPACT
FLUORESCENT BALLASTS
MAGNETIC AND ELECTRONIC COMPACT
FLUORESCENT BALLASTS
T5 LONG TWIN
40-96 WATTS
transforming the power of light
4-14
LONG TWIN T5 BALLASTS
40, 50, 55 & 96 WATTS
(BIAX, DULUX L AND PLL)
DIMENSIONS
All ballasts are UL listed, CSA approved and designated Class P (thermally protected).
Lamp Type
40 Watts
FT40W/2G11
Long Twin T5,
4-Pin
RS = Rapid Start; IS = Instant Start; PRS = Programmed Rapid Start
Standard cases offer side lead configuration.
New auto reset shutdown circuit
Incorporates shutdown circuit
Not approved for use in hazardous locations.
Lamp Type
50 Watts
FT50W/2G11
Long Twin
T5, 4-Pin
Lamp Type
96 Watts
FT96W/GY10q
Long Twin
T5, 4-Pin
Lamp Type
55 Watts
FT55W/2G11
Long Twin
T5, 4-Pin
REFERENCE DRAWING FOR -B
Dwg. L W H M X
-B 9.50” 1.50” 1.00” 8.89” 0.88”
-D 16.88” 1.18” 1.00” 16.20” ---
-SL 11.75” 3.13” 1.78” 11.41” 2.00”
REFERENCE DRAWING FOR -SL
REFERENCE DRAWING FOR C6
Dwg. A B C D E F
C6 2.40” 1.55” 8.31” 8.89” 9.50” 1.19”
B
C
AF
E
D
5/16 "
111/16"
Lead Lengths:
Magnetic
Black/White-20˝
Red/Blue/Yellow -30˝
Electronic
Black/White-24˝
Red/Blue-30˝
Yellow - 4
REFERENCE DRAWING FOR -D
GE Product Code Mag Qty Line Starting Min
Side Bottom Bottom or of Line Catalog Input Current Current Ballast Start Power Starting Wir
Exit Exit Exit Studs Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD MethodDim Diag
Electrical Characteristics - 60 Hz
87625 M 2 120 4152P85 0.68 —— 0.90 50°F High <20% RS C6 5
80680 —
E1 120 C240SI120RH40 0.40 —— 1.02 50°F High <20% IS C6 12
80681 —
E1 277 C240SI277RH40 0.17 —— 1.02 50°F High <20% IS C6 12
80683 — E 1 120C240PUNVHP-B
41 0.34 —— 1.00 0°F High <10% PRS -B 20
277 40 0.15
80690 E 2 120 C340SI120RH75 0.68 —— 0.99 50°F High <20% IS C6 14
80691 E 2 277 C340SI277RH75 0.28 —— 0.99 50°F High <20% IS C6 14
80680 E 2 120 C240SI120RH69 0.61 —— 0.88 50°F High <20% IS C6 12
80681 E 2 277 C240SI277RH69 0.27 —— 0.88 50°F High <20% IS C6 12
80683 — E 2 120 C240PUNVHP-B• 76 0.63 —— 0.90 0°F High <10% PRS -B 20
277 73 0.27
80690 E 3 120 C340SI120RH98 0.88 —— 0.88 50°F High <20% IS C6 14
80691 E 3 277 C340SI277RH98 0.39 —— 0.88 50°F High <20% IS C6 14
80136 E 3 347 B332I347HP 97 0.28 —— 0.85 50°F High <10% IS C6 14
47542 —
E1
120 B254PUNV-D• 60 0.50 —— 1.29 0°F High <10% PRS -D 27
277 0.23
47542 —
E2
120 B254PUNV-D• 111 0.93 —— 1.18 0°F High <10% PRS -D 27
277 108 0.40
47542 —
E1
120 B254PUNV-D• 58 0.49 —— 0.90 0°F High <10% PRS -D 27
277 0.22
47542 —
E2
120 B254PUNV-D• 106 0.89 —— 0.82 0°F High <10% PRS -D 27
277 104 0.38
80162 E 2 120 B295SR120HP 172 1.44 —— 0.93 -20°F High <10% SER-RS SL 4
80163 E 2 277 B295SR277HP 172 0.63 —— 0.93 -20°F High <10% SER-RS SL 4
WIRING DIAGRAMS
BALLAST
Black
Black
Line
Black
White
Yellow
Yellow
Red
Red
Blue
Blue
BALLAST
Line
BALLAST
Line
Blue
Blue
White
Black
Line
Black
White Blue
Blue
BALLAST
BALLAST
Line
Blue
Blue
Red
Red
Black
White
Yellow
Yellow
Black
White
Blue
BALLAST
Line
DIAGRAM 1 DIAGRAM 5 DIAGRAM 7A
DIAGRAM 8A DIAGRAM 9DIAGRAM 8
DIAGRAM 13 DIAGRAM 15DIAGRAM 11
BALLAST
Black
Line White Red
Blue
Blue
Red
Yellow
Yellow BALLAST
Black
Line White
Red
Blue
Blue
Red
Yellow
Yellow
BALLAST
Black
Line White
Red
Blue
Blue
Red/White
Red/White
Red
QUICK
REFERENCE
Nominal lamp
watts and
configuration
MAGNETIC AND ELECTRONIC COMPACT
FLUORESCENT BALLASTS
transforming the power of light
4-16
WIRING DIAGRAMS
WIRING DIAGRAMS
DIAGRAM 18A DIAGRAM 19
Black
White Red
Red
Blue
Blue
BALLAST
Green
Black
White Red
Red
Blue
Blue
BALLAST
Green
Black
White Red
Blue
Yellow
BALLAST
Green
Red
Yellow
Blue
DIAGRAM 18
DIAGRAM 20 DIAGRAM 21DIAGRAM 19A
DIAGRAM 23
Red
Blue
Yellow
BALLAST
Black
White
Green
Red
Blue
Yellow
BALLAST
Black
White
Green
Red
Yellow
Blue
Black
White
Green
Red
Red
Yellow
Yellow
Blue
Blue
BALLAST
Mount lamp within 1" of grounded metal reflector.
BALLAST
Black
Line
White
Green
Red
Red
Blue
Blue
BALLAST
Black
White
Green
Red
Blue
DIAGRAM 27
DIAGRAM 28
5-1
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
For more information, visit www.gelighting.com
GE MEANS HIGHER EXPECTATIONS IN
HIGH INTENSITY DISCHARGE.
GE offers a wide line of ballasts for all High Intensity Discharge (HID)
lamp types (mercury, vapor, metal halide and high-pressure sodium)
for applications ranging from 35-2000 watts, including core & coil,
electronic, F-Can, potted core & coil, weatherproof, postline, and
indoor encased ballasts. Our line includes the latest innovation in
magnetic core & coil technology in years.
GE offers a wide line of HID ballasts for
applications ranging from 35-2000 watts.
HIGH INTENSITY
DISCHARGE
BALLASTS
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
5-2 5-3
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
transforming the power of light
For more information, visit www.gelighting.com
PRODUCT
OVERVIEW
PRODUCT
OVERVIEW
PRODUCT OVERVIEW PRODUCT OVERVIEW
Core & Coil
Core & coil ballasts are used in over 90% of all
HID fixtures. GE‘s core & coil models are available for
all HID lamp types, including single-, dual-, tri-, and
multi-voltage designs. For added versatility and
reduced inventory costs, GE has also introduced the
industry's first Multi-5ballast (120, 208, 240, 277,
or 480 Volt), featuring a 480-Volt tap on a conven-
tional quad tap ballast.
Our core & coil models are ideal for a wide variety
of lighting applications, including factories, warehouses,
gymnasiums and retail stores. All these ballasts feature
precision-wound coils, ensuring even heat dissipation
and the highest electrical integrity.
GE‘s Preciseis the next generation in core & coil
technology, featuring a smaller, lightweight design and
improved temperature performance. Precisefits virtu-
ally all applications, and has no exposed live metal
parts. There are no plastic extrusions, which prevents
breakage during shipping. Color-coded leads make
installation easy.
F-Can
These ballasts are used primarily for indoor down-
lighting applications where quiet operation is essen-
tial. All the components of these ballasts are enclosed
in a fluorescent-style ballast can and are thermally
protected.
Potted Core & Coil
Our potted core & coil ballasts are designed for
applications requiring quieter or cooler operation
than provided by standard coil & coil ballasts. The
potting material is a sand-filled polyester which
provides excellent sound-deadening and heat trans-
fer qualities.
HID Multi-5Ballasts
Core & Coil Ballasts
HID Ballast Kits
REMOTE MOUNTING DISTANCE
Maximum Length in Feet for Remote Mounting of HID Ballasts to Lamp
For proper installation, ensure that remote ballasts are properly vented and mounted to a heat-dissipating surface.
ANSI Lamp Type Watts 12 GA 14 GA 16 GA 18 GA
H45 Mercury 40 534 336 211 132
H46 Mercury 50 498 313 197 123
H43 Mercury 75 620 390 245 154
H38 Mercury 100 620 390 245 154
H39 Mercury 175 272 171 107 67
H37 Mercury 250 194 122 77 48
H33 Mercury 400 132 83 52 33
H35 Mercury 700 297 187 117 74
H36 Mercury 1000 208 131 82 51
M57 Metal Halide 175 272 171 107 67
M58 Metal Halide 250 194 122 77 48
M59 Metal Halide 400 132 83 52 33
M47 Metal Halide 1000 196 123 77 48
M48 Metal Halide 1500 146 92 58 36
HID Capacitors F-Can Ballasts
Multi-5Uni-Pak
Weatherproof
GE's weatherproof ballasts are designed to stand
up to the toughest outdoor conditions. They can be
mounted remotely in the pole base or pole top. Since
they're not hermetically sealed, they should not be
mounted in areas prone to water accumulation.
Indoor Encased
Our HID indoor encased ballasts can be mounted
remotely, which lets you use a smaller HID fixture while
ensuring quiet operation. If necessary, these ballasts
can be specified with an integral capacitor and starter.
Ignitors
GE offers the industry's most complete line of igni-
tors, including standard, automatic shutoff, instant
restrike, and long distance ignitors.
5-5
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
5-4
transforming the power of light
PRODUCT OVERVIEW APPLICATION AND OPERATING INFORMATION
OIL–FILLED CAPACITORS
Normal Position of Protective
Device
Protective Device (Only in metal cases)
Protective device to prevent case rupture
Barrier
Position of Protective Device
After Activation
Barrier
Normal Cover Position
1/2"
Plastic Dry Type Capacitors Metal and Oil Filled Capacitors
For maximum safety and reliability, all GE capaci-
tors come with built-in bleed resistors. All GE capaci-
tors are recognized by UL (UL file #E68320 for metal
cases and #E182721 for plastic cases) and approved
by CSA (CSA file #LR51331, metal cases only).
Environmental safety is assured by use of biodegrad-
able, nontoxic (no PCBs) dielectric fluid (soybean oil),
patented for use in capacitors. Dry-film capacitors do
not include protective devices. Since they can fail in a
hazardous manner, it is the responsibility of the pur-
chaser to take appropriate precautions.
Capacitors
GE has a comprehensive line of capacitors in metal
cases (up to 520V ratings) and plastic cases (up to 400V
ratings) – plus metal cases for dual-level operation. All GE
capacitors are designed for 60,000 hours of continuous
life. They're exceptionally reliable because we put them
through accelerated life testing at 125% rated voltage
and 110% of rated temperature +10°C.
GE capacitors are normally packaged with ballasts. They
may also be ordered separately, bulk packaged, or individual-
ly boxed with the suffix “BH” (metal cases only). Capacitor
weights vary from 1/4 lb. to 1 lb. each.
Dry Capacitors
Type “P” plastic case capacitors described in this sec-
tion are dry and do NOT contain safety interrupters (or
oil). Plastic cases are UL rated “94V-O” (for use up to
100°C maximum). Type "P" capacitors are supplied with
stranded copper wire leads 8 inches long (18 AWG, with
150°C rated insulation). Capacitor rolls are sealed inside
plastic cases using epoxy. Design and testing of GE
capacitors follow specifications in Electronic Industries
Association (EIA) Standard 456-A, titled “Metalized Film
Dielectric Capacitors for Alternating Current
Application.”
“P” capacitors are designed and rated for continu-
ous duty AC voltages below 400VAC @ 50 or 60 Hz.
Capacitors used with HID ballasts at voltages above
400VAC should contain interrupters (available from GE in
oval “MF” and round “RMF” oil-filled metal cases).
GE Product
Code uF VACr Part # Case Ht (")
89078 12.0 400 005-2799-MF 1.50 oval 2.7
88982 15.0 400 005-1185-MF 1.75 oval 2.7
89083 24.0 360 005-3160-MF 1.75 oval 3.1
89071 24.0 400 005-2664-MF 1.75 oval 3.1
89077 24.0 480 005-2779-MF 1.75 oval 3.9
89007 48.0 330 005-1422-MF 1.75 oval 3.9
PRODUCT
OVERVIEW
APPLICATION &
OPERATING INFO.
1.81" 1.30"
0.58"
0.93"
0.43"
.29"
0.25" Dia.
2 Holes
0.09"
5.50"
0.93"
0.29"
0.90"
1.75"
45º
5-7
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
BRACKET
REFERENCE
5-6
transforming the power of light
BRACKET REFERENCE CHART APPLICATION AND OPERATING INFORMATION
CORE & COIL
WELDED BRACKETS
All welded brackets are .093" thick.
Ref. Drawing B1
0.75"0.25"
4.00"
3.35" 0.30"
0.75"0.25"
4.00"
3.35" 0.30"
1.00"
1.25"
5.25"
4.60"
.250 Slot
2 Places
1.25"
7.75"
7.75"
.281 Slot
2 Places
1.75"
on center
2.75"
7.75"
6.75"
on center
0.50"
0.50"
TYP.
6.10"
on center
.281 Slot
6 Req.
R. TYP.
Ref. Drawing B2
Ref. Drawing B1-A
1.00"
0.25"
5.25"
4.60"
Ref. Drawing B1-B
Ref. Drawing B3
Ref. Drawing B4
CORE & COIL
ADJUSTABLE
MOUNTING
BRACKETS
Routinely supplied with replacement kits.
All welded brackets are .093" thick.
For use with:
• 50 to 175 watt Mercury, High Pressure Sodium
and Metal Halide and some 250 watt Metal Halide
For use with:
• 250 to 1500 watt Metal Halide
• 250 to 1000 watt High Pressure Sodium and
Mercury Vapor
7.25"
1.300"
.090"
.580" .930"
.735"
.290"
1/4" Dia.
2 Holes
.290"
45°
1. 880"
2.685" 1.750"
.835"
.460"
Ref. Drawing
ADJ2
Ref. Drawing
MB1
Ref. Drawing
MB2
APPLICATION &
OPERATING INFO.
Underwriters Laboratories, Inc. Acceptance
All F-Can and weatherproof ballasts listed in this
catalog are Underwriters Laboratories, Inc. white
card listed, except those for 347 Volt operation. All
core & coil, potted core & coil and postline ballasts
listed in this catalog are Underwriters Laboratories,
Inc. yellow card listed (component recognized).
Ballast Replacement
Ballast replacement presents the possibility of
exposure to potentially hazardous voltages and
should be performed only by qualified personnel. All
installation, inspection and maintenance should be
performed only with the entire circuit power to fix-
ture or equipment turned off. Installation shall be in
accordance with National Electric Code.
Heat
A ballast, like any other electrical device, gener-
ates heat during normal operation. Planning for
maximum heat dissipation with proper fixture
design, installation planning and ballast selection will
minimize the possibility of a heat-related problem
arising. Excessive temperature will have an adverse
effect on ballast life.
Normal Temperature Limits:
• F-Can Ballasts
Maximum case temperature: 90°C
• Weatherproof Ballasts
Maximum case temperature: 90°C
• Core & Coil Ballasts and
Potted Core and Coil Ballasts
Insulation: Class 180°C
Maximum coil temperature: 165°C
(measured by change of resistance method)
All F-Can ballasts listed in this catalog are
equipped with built-in automatic resetting internal
thermal protection as a standard feature.
Other ballast types may be available with ther-
mal protection as an option. If required, consult your
GE representative for availability and ordering infor-
mation.
Whenever a ballast with thermal protection is
used, it is imperative that the fixture/ballast/lamp
combination be heat tested under actual or simulat-
ed installation conditions to assure that the ballast
will not cycle.
The resetting thermal protector functions as a
thermostat which will open and temporarily deacti-
vate the ballast when it exceeds the permissible tem-
perature. The ballast will continue to cycle until the
cause of overheating is eliminated. If the ballast is
defective, it must be replaced. If the cause is exter-
nal, the ballast will resume normal operation after
abnormal conditions are eliminated.
To attain normal ballast life, the maximum coil
temperature of the ballast should not exceed the rat-
ing of the insulation system. A temperature increase
of 10°C results in a 50% reduction of ballast life.
Low Ambient Temperature (Cold)
As temperatures drop, less and less vaporized
gas is available within the arc tube of a high intensity
discharge lamp, thereby causing an increase in the
open circuit voltage required to initiate an arc in the
lamp, until a point is reached where the lamp cannot
be started. The minimum temperature at which any
ballast listed in this catalog will provide reliable start-
ing is listed with the electrical characteristics.
Low ambient temperatures will also result in a
slight increase in the warm-up period of any type of
high intensity discharge lamp.
Ballasts should be protected from weather, mois-
ture, or other abnormal atmospheric conditions,
unless specifically designed for use under adverse
conditions.
Fusing
The purpose of fusing an HID ballast is to
remove the ballast from the power line in the event
of a ballast system failure. A fuse does not protect
the ballast from failing.
Because the temperature in the ballast
compartment is high, typically 90OC, fuse ratings are
specified at 25OC, and that this rating declines as the
temperature increases, HID fuse recommendations
are made between 2 and 3 times the maximum
current the ballast will draw during all normal
conditions.
Fast-blow fuses should not be used due to the
possibility of high inrush currents. These currents are
due to the fact that the power can be applied at any
point in the AC voltage waveform. Standard and
slow-blow are acceptable.
When using the 120V tap for auxiliary lighting, a
slow-blow fuse should be used to protect the ballast
from damage from a fault in the auxiliary lighting
circuit.
Ref. Drawing
ADJ1
5-9
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
5-8
transforming the power of light
APPLICATION AND OPERATING INFORMATION
APPLICATION &
OPERATING INFO.
Sound
High intensity discharge lamp ballasts, like all
electromagnetic devices, produce noise, or “hum.” It
is the degree of noise which determines the exis-
tence of a problem. Ballast noise will only be notice-
able when it exceeds the ambient sound level of the
installation. It is obvious that a ballast designed pri-
marily for outdoor or factory use would not be suit-
able in an office environment.
The vast improvements in all high intensity dis-
charge lamps and ballasts, and their excellent
energy efficiency, have made them viable options
for many indoor applications. The ballasts being
considered should be carefully analyzed to ensure
that there will not be an objectionable level of bal-
last noise.
All F-Can ballasts listed in this catalog are
“Sound Rated” to aid in the selection of a ballast
that is proper for the environment in which it will
operate.
Potted core & coil ballasts are also designed to
operate at reduced sound levels, generally several
decibels lower than a standard core & coil ballast.
Core & coil ballasts are not sound rated.
In situations where light output necessitates
using a ballast with a sound rating or noise level
not normally acceptable, the ballast should be
remotely mounted. Note, however, that not all bal-
lasts listed in this catalog are designed or recom-
mended for remote mounting.
Polarity
Polarity refers to the proper connection of bal-
last lead wires to line wires. To aid you in making a
correct installation, GE ballast leads are color-coded
for easy identification. The white or yellow ballast
lead is to be connected to the neutral or common.
Choose the appropriate ballast voltage lead to con-
nect to the line.
Grounding
Ballast and capacitors or starters in metallic
casings must always be grounded. Ballasts and
components may be grounded to the fixture or
otherwise grounded. It would be hazardous to
make contact with an ungrounded fixture, ballast
or other electrical component while in operation.
Operating Line Voltage Limits
To receive the full benefits of rated lamp out-
put and to prolong ballast life, it is essential that
voltage supplied to an installation be maintained
within the prescribed limits.
In general, the line voltage supplied to a lag
type ballast (reactor or high reactance autotrans-
former) should be maintained within 5% of the
voltage for which the ballast is rated. The line volt-
age to lead type ballasts (constant wattage auto-
transformer or constant wattage isolated) should
be maintained within 10%.
Subjecting a ballast to excessive voltage for an
extended period of time results in the deterioration
of the coil insulation. This insulation breakdown
will cause early ballast failure.
Low voltage has no damaging effect on the
ballast. It could, however, have an adverse effect
on lamp performance and starting dependability.
Maintenance
Selecting and installing an adequate and
efficient lighting system means nothing if it is
not properly maintained. Maintenance must
always be considered as part of the life cycle
cost of any high intensity discharge lighting
installation in order to assure the continued per-
formance of the system as originally specified.
First and foremost in importance is proper
lamp maintenance. High intensity discharge
lamps do not “burn out” like an incandescent
bulb, but rather, undergo changes with the arc
tube which prevent the lamp from starting prop-
erly, warming up and producing full light output.
The beginning of difficulties such as these gener-
ally indicates the end of a lamp's useful life. Also,
a dead lamp left in a fixture can be very damag-
ing to the ignitor in systems which utilize them.
To overcome this problem, GE offers automatic
shutoff ignitors, which are described in the igni-
tor section of this catalog.
In difficult locations, group replacement of all
the lamps, working or not, is often more economi-
cal and convenient than spot replacement. The
same, of course, applies to ballasts which might
be approaching the end of their life. Only you can
decide what is right for your lighting system, but
what is important is that you have a maintenance
program.
APPLICATION AND OPERATING INFORMATION
APPLICATION &
OPERATING INFO.
Periodic cleaning of the fixtures‘ lenses and
reflectors is also important in maintaining proper
light output. For indoor systems, maintenance of
reflective surfaces, such as walls and ceilings, will
also help assure proper levels of illumination.
Standby Lighting and Packaging
Standby Lighting
To provide light during a high intensity discharge
lamp's warm-up period, or the cool-down period
following a power interruption which has extin-
guished it, incandescent standby lighting can be
incorporated. This is accomplished by use of a
standby lighting device, or remote, that switches off
an incandescent lamp incorporated into the fixture
once an arc has been established, or reestablished,
in the HID lamp. Generally, standby lighting devices
operate on 120 Volts, so a tap must be provided on
ballasts designed to operate at higher line voltages.
The 120 Volt terminal or lead on all GE dual-,
tri- and multi-voltage ballasts can be used as a tap
for standby lighting when the ballast is utilized for
any of the higher voltages. Many single voltage bal-
lasts are available with a 120 Volt tap and are listed
throughout the core & coil data section. Other sin-
gle voltage ballasts may be available in this version.
Consult your GE representative for availability and
price information.
Any connection to the 120 Volt tap must be
accomplished by means of a slow-blow fuse. This
fuse will protect the ballast from abnormal condi-
tions in the standby lamp circuit or its control
device. The fuse should be located in the coolest
place in the fixture (below 80°C). The recommend-
ed fuse amperage and maximum auxiliary lamp
wattage are listed in this catalog for each ballast
suitable for standby lighting applications.
Be sure to follow the wiring instructions of the
standby lighting device manufacturer. All applicable
requirements of the National Electrical Code must
be met.
Packaging
Standard Pack
GE high intensity discharge lamp ballasts are
routinely packed in easy-to-handle cartons contain-
ing from 1 to 20 units per carton, depending on the
size and weight of the ballasts. Consult your GE
representative regarding the number of “units per
carton” for shipment with attached mounting
brackets, capacitors (for high power factor units),
and ignitors (if required). Other ordering criteria may
cause packaging to vary.
Individual Cartons
All distributor replacement kits, weatherproof,
postline, potted core & coil, and many larger bal-
lasts are packaged in individual cartons.
Individual cartons serve a threefold purpose: as
a display carton, a stock package, and a shipping
container for the retail market. Individual cartons
may be packed in master cartons, depending on
weight and size.
Individual carton packaging may be available for
other ballasts. Contact your GE representative
regarding availability and cost.
5-11
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
SPECIFICATIONS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
NOMENCLATURE
5-10
transforming the power of light
NOMENCLATURE TYPICAL SPECIFICATIONS FOR HID BALLASTS
ABBREVIATIONS
CWA Constant Wattage Autotransformer
CWI Constant Wattage Isolated
ISO Regulated Lag
R-HPF Reactor—High Power Factor
R-NPF Reactor—Normal Power Factor
HX-HPF Lag Type — High Reactance
Autotransformer—High Power Factor
HX-NPF Lag Type — High Reactance
Autotransformer—Normal Power
Factor
UL Bench Top Rise Temperature Code
To facilitate UL inspection, the UL Bench Top
Rise Temperature Code is shown on the core &
coil ballast label as 1029X. 1029 is the UL
Standard for HID Ballasts, and the X is the
temperature code. If a fixture is UL listed for
1029D, then automatically all ballasts with an
A, B, C or D temperature classification are
acceptable for use within that same fixture.
UL Bench Top Rise Letter Code
Temperature Range for
Class H (180°C) Ballasts
A<75°C B75°C<80°C
C80°C<85°C D85°C<90°C
E90°C<95°C F95°C<100°C
1 2 3 4 5 6 7 8 9
Number of Digits
1 2 to 4 3 1 1 1 1 3 1
M 2 0 0 0 M L T A C 5 M 0 0 0 C
Field Description
1(M) Metal Halide, (P) Pulse Start Metal Halide, (S) High Pressure Sodium, (H) Mercury
235 to 2000 Watts (Varies from two to four digits)
3(MLT) Quad, (ML5) Multi-5, (TRI) TriVolt, (48T) 480/120, (120) 120, (277) 277, (230) 230V/50Hz
4(R) Reactor, (A) CWA, (I) CWI, (O) IsoReg, (L) High Reactance/Lag, (M) MagLag
5(C), C&C, (F) F-Can, (W) Weatherproof, (E) Encased/Potted C&C (I) Indoor Encased
6(E) E&I, (3) 3x4, (4) 4-3/4, (5) 5-3/4, (X) Non Core and Coil
7(M) Mogul or Medium, (D) Double Ended, (X) Multiple Lamps, (L) Low Loss
8Pack Code (000 to 999, per pack code listing)
9(C) Carton, (T) Tray, (I) Individual, (K) Kit
Field
Lamp Type
(M/P/S/H)
Wattage
Primary Voltage
(MLT/ML5/TRI/48
T/
120/277/
230)
Circuit Type
(R/A/I/O/L/M)
Style
(C/F/W/E/I/P)
Frame Size
(E/3/4/5/X)
Socket Type &
Other Oddities
(M/D/X/L)
Pack Code
(000 TO 999)
Container Type
(C/T/I/K)
1. Ballasts shall be designed in accordance with all
applicable ANSI specifications including ANSI
C82.4
2. The Core & Coil ballast shall be designed with
class "H" (180°C) or higher insulation system
and vacuum impregnated with a 100% solids
based resin.
3. All coils shall be precision wound.
4. Core & Coil ballasts shall be designed to oper-
ate at least 180 cycles of 12 hours on and 12
hours off, with the lamp circuit in an open or
short-circuited condition and without undue
reduction in ballast life.
5. Core & Coil ballast and starter combinations
shall be designed to provide a reliable lamp start-
ing down to -40°C for High Pressure Sodium
and -30°C for Metal Halide at minimum rated
line voltage.
6. Manufacturer shall provide written warranty
against defects in workmanship, including
replacement, for two years from date of man-
ufacture.
Capacitors
1. All capacitors will be provided with a self-con-
tained internal bleeder resistor.
2. All oil-filled capacitors will be housed in corro-
sion-resistant steel cans and contain .25" quick
disconnect terminals.
3. All capacitors will be manufactured by ballast
manufacturer.
Ignitors
1. All ignitors will be epoxy-filled with either a
plastic or aluminum external housing.
2. The ignitor shall be so designed to provide six
months of lamp open circuit operation without
failure.
Kits
1. All HID kits shall be precision wound to ensure
proper installation.
2. All HID kits shall be pre-wired.
3. All HID kits shall be built with color-coded
leads.
4. All HID kits are to be UL and CSA recognized
following the guidelines found in UL 1029 and
CAN/CSA-22.2 No.74-92 (part 2 and 3).
5. GE Model______________ ( o r approved equal).
5-13
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
DISTRIBUTOR
REPLACEMENT KITS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
DISTRIBUTOR
REPLACEMENT KITS
5-12
transforming the power of light
DISTRIBUTOR REPLACEMENT KITS
GE's HID distributor replacement kits contain
the appropriate core & coil, a properly rated capac-
itor, and all other components required for ballast
replacement. Our kits are the quickest and easiest
to install of any on the market, thanks to unique
design features like:
• Prewired capacitor and ignitor (if required) to
save time and reduce wiring errors
• Color coded leads to reduce risk of incorrect
wiring inside the fixture
• Features that exceed UL standards, including
capacitors that offer trip fault protection
• Simple installation instructions and trou-
bleshooting tips
• UPS shippable box
Our kit offerings include many quad-voltage
(120, 208, 240, or 277 volt) and 480 Volt core &
coil ballasts, as well as the new Multi-5 five-volt-
age ballast. 480 Volt ballasts are equipped with a
120 Volt tap to accommodate standby lighting.
GE‘s Multi-5™ Ballast Lamp Replacement kit is
available for metal halide and high pressure sodi-
um applications. This easy to carry, convenient, all-
in-one kit ensures ballast lamp compatibility.
Distributor replacement kit cartons are pack-
aged in master cartons in quantities from 1 to 6
units.
Master carton quantities can be found on GE's
list and distributor price sheets.
Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits
Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits
Lamp Type Wattage Voltage Frame Size GE Product Code Part Number
Metal 150 480-120 3 x 4 86711 M15048TLC3M500K
Halide 175 Multi-5 3 x 4 87210 M175ML5AC3M500K
175 120/208/240/277 3 x 4 86741 M175MLTAC3M500K
250 Multi-5 3 x 4 87211 M250ML5AC3M500K
250 120/208/240/277 3 x 4 86765 M250MLTAC3M500K
250 Multi-5 4.25 x 4.75 87212 M250ML5AC4M500K
250 Multi-5™ Uni-Pak3 x 4 49763 M250ML5AC3M555K
250 Multi-5™ Uni-Pak4.25 x 4.75 49742 M250ML5AC4M555K
400 Multi-5 4.25 x 4.75 86808 M400ML5AC4M500K
400 120/208/240/277 4.25 x 4.75 86814 M400MLTAC4M500K
400 480-120 4.25 x 4.75 86803 M40048TAC4M500K
400 Multi-5™ Uni-Pak4.25 x 4.75 49745 M400ML5AC4M555K
1000 Multi-5 4.25 x 5.75 87213 M1000ML5AC5M500K
1000 120/208/240/277 4.25 x 5.75 86655 M1000MLTAC5M500K
1000 480-120 4.25 x 5.75 86650 M100048TAC5M500K
1500 120/208/240/277 4.25 x 5.75 86698 M1500MLTAC5M500K
1500 480-120 4.25 x 5.75 86693 M150048TAC5M500K
Pulse 175 120/208/240/277 3 x 4 86885 P175MLTAC3M500K
Start 175 480-120 3 x 4 86876 P17548TAC3M500K
Metal 250 120/208/240/277 4.25 x 4.75 86935 P250MLTAC4M500K
Halide 250 480-120 4.25 x 4.75 86926 P25048TAC4M500K
320 120/208/240/277 4.25 x 4.75 86959 P320MLTAC4M500K
320 480-120 4.25 x 4.75 86952 P32048TAC4M500K
350 120/208/240/277 4.25 x 4.75 86984 P350MLTAC4M500K
Lamp Type Wattage Voltage Frame Size GE Product Code Part Number
400 120/208/240/277 4.25 x 4.75 87008 P400MLTAC4M500K
400 480-120 4.25 x 4.75 86999 P40048TAC4M500K
750 480-120 4.25 x 5.75 46936 P75048TAC5M500K
HPS 50 120/208/240/277 3 x 4 87152 S50MLTLC3M500K
70 120/208/240/277 3 x 4 86587 S70MLTLC3M500K
70 480-120 3 x 4 86456 S7048TLC3M500K
100 120/208/240/277 3 x 4 87074 S100MLTLC3M500K
100 480-120 3 x 4 87068 S10048TLC3M500K
150 120/208/240/277 3 x 4 87094 S150MLTLC3M500K
150 480-120 3 x 4 87087 S15048TLC3M500K
250 Multi-5 4.25 x 4.75 87214 S250ML5AC4M500K
250 120/208/240/277 4.25 x 4.75 87121 S250MLTAC4M500K
250 Multi-5™ Uni-Pak4.25 x 4.75 49757 S250ML5AC4M555K
400 Multi-5 4.25 x 4.75 8725 S400ML5AC4M500K
400 120/208/240/277 4.25 x 4.75 87164 S400MLTAC4M500K
400 480-120 4.25 x 4.75 87198 S40048TAC4M500K
400 Multi-5 4.25 x 5.75 87217 S400ML5AC5M500K
400 120/208/240/277 4.25 x 5.75 87175 S400MLTAC5M500K
400 480-120 4.25 x 5.75 87206 S40048TAC5M500K
400 Multi-5™ Uni-Pak4.25 x 4.75 49758 S400ML5AC4M555K
1000 Multi-5 4.25 x 5.75 87218 S1000ML5AC5M500K
1000 120/208/240/277 4.25 x 5.75 87056 S1000MLTAC5M500K
1000 480-120 4.25 x 5.75 87048 S100048TAC5M500K
Mercury 100 120/208/240/277 3 x 4 86519 H100MLTAC3M500K
175 120/208/240/277 3 x 4 86527 H175MLTAC3M500K
400 120/208/240/277 4.25 x 4.75 86542 H400MLTAC4M500K
5-15
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
MH 150-175 WATTS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
5-14
transforming the power of light
MH 35-100 WATTS
MH 35/39 WATTS
CORE & COIL ELECTRONIC BALLASTS
METAL HALIDE LAMPS
Nom Dimensions Capacitor Ignitor
GE Max Open Total M ax UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Voltage Rating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 35/39 WATT M130 METAL HALIDE LAMP
120 or 1.16 3
208 or 0.67 3
86824 240 or M50MLTLC3M500K HX-HPF 67 0.57 2 4PC1 1.0 2.6 6 280 1.2 2.2 1.31x2.16 2.2 4.3 MH100-3A 10 A
277 0.50 2
DIMENSIONS
DESCRIPTION SUFFIX *
For Ballast Only 000
For Bracket Only (see pg. 5-6) 200
For Capacitor Only (see pg. 5-6) 500
For Distributor Replacement Kit
(see pg. 5-12 thru 5-13) 500K
BRef. Dwg. L W M S
14.00" 0.75" 3.35" 0.25"
PC1 5.25" 1.25" 4.60" 0.25"
M
L
WS
Bracket
See pg. 5-6 for adjustable mounting brackets and
detailed bracket drawings.
B
MAX
0.250 Dia Thru
2 Holes
0.199 Dia Thru
4 Holes
A
2.438˝
2.812˝
3.500˝3.938˝
REFERENCE DRAWING PC1
MH 70 WATTS
Nom Dimensions Capacitor Ignitor
GE Max Open Total M ax UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Voltage Rating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 70 WATT M98 METAL HALIDE LAMP – Medium Base
120 or 1.70 4 A
86847 208 or M70MLTLC3M500K HX-HPF 95 1.04 245 34PC1 1.3 2.9 8 280 1.2 2.7 1.31x2.16 2.2 4.3 MH100-3A 10 B
240 or 0.87 3 B
277 0.78 2 B
86839 480-120 M7048TLC3M HX-HPF 95 0.50 245 1 6 PC1 1.3 2.9 8 300 1.2 2.7 1.31x2.16 2.2 4.3 MH100-3A 10 E
MH 100 WATTS
Nom Dimensions Capacitor Ignitor UL
GE Max Open Total Max Bench
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Top
Code Volts Number Type Input Current Vltg Rtg Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Rise
(1) 100 WATT M90 OR M92 METAL HALIDE LAMP - Medium Base
120 or 2.30 5
86675 208 or M100MLTLC3M500K HX-HPF 130 1.30 250 44PC1 1.7 3.2 10 280 1.2 2.7 1.31x2.16 2.2 6.3 MH100-3A 10 A
240 or 1.10 3
277 0.95 3
86667 480-120 M10048TLC3M500K HX-HPF 140 0.62 250 2 6 PC1 1.7 3.2 10 280 1.2 2.7 1.31x2.16 2.2 5.0 MH100-3A 10 C
CORE & COIL ELECTRONIC BALLASTS
METAL HALIDE LAMPS
DIMENSIONS
MH 150 WATTS
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Vltg Rtg Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 150 WATT M102 METAL HALIDE LAMP - Medium Base
120 or 3.32 10
86718 208 or M150MLTLC3M500K HX-HPF 185 1.93 245 54PC1 2.3 3.9 16 300 1.6 2.7 1.56x2.69 2.7 7.3 MH100-3A 10 D
240 or 1.66 5
277 1.48 4
86711 480-120 M15048TLC3M500K HX-HPF 180 1.00 245 2 6 PC1 2.3 3.9 16 280 1.6 2.7 1.56x2.69 2.7 7.3 MH100-3A 10 F
BRef. Dwg. L W M S
14.00” 0.75” 3.35” 0.25”
PC1 5.25” 1.25” 4.60” 0.25”
M
L
WS
Bracket
See pg. 5-6 for adjustable mounting brackets and
detailed bracket drawings.
B
MAX
0.250 Dia Thru
2 Holes
0.199 Dia Thru
4 Holes
A
2.438˝
2.812˝
3.500˝3.938˝
REFERENCE DRAWING PC1
MH 175 WATTS featuring Multi-5
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Voltage Rating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 175 WATT M57, M107 METAL HALIDE OR H39 MERCURY LAMPS
120 or 1.80 5 A
86741 208 or M175MLTAC3M500K CWA 213 1.10 310 321 PC1 2.2 3.6 10 400 1.6 2.7 1.56x2.69 2.7 6.8 n/a n/a B
240 or 0.90 3 A
277 0.78 2 A
120 or 208 1.90 5
208 or 208 1.10 3
87210 240 or M175ML5AC3M500K CWA 208 0.95 300 3 44 PC1 2.3 3.6 10 400 1.6 2.7 1.56x2.69 2.7 6.8 n/a n/a B
277 or 208 0.85 2
480 210 0.50 1.5
DESCRIPTION SUFFIX *
For Ballast Only 000
For Bracket Only (see pg. 5-6) 200
For Capacitor Only (see pg. 5-6) 500
For Distributor Replacement Kit
(see pg. 5-12 thru 5-13) 500K
5-17
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
5-16
transforming the power of light
MH 250 WATTS
CORE & COIL ELECTRONIC BALLASTS
METAL HALIDE LAMPS
DIMENSIONS
BRef. Dwg. L W M S
14.00” 0.75” 3.35” 0.25”
PC1 5.25” 1.25” 4.60” 0.25”
PC 2 5.25” 1.25” 4.60” 0.25”
M
L
WS
Bracket
See pg. 5-6 for adjustable mounting brackets and
detailed bracket drawings.
B
MAX
0.250 Dia Thru
2 Holes
0.199 Dia Thru
4 Holes
A
2.438˝
2.812˝
3.500˝3.938˝
REFERENCE DRAWING PC1 REFERENCE DRAWING PC2
MH 250 WATTS featuring Multi-5
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Voltage Rating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 250 WATT M58 METAL HALIDE OR H37 MERCURY LAMP - 4" Frame
120 or 2.60 8 C
86765 208 or M250MLTAC3M500K CWA 294 1.58 280 521 PC1 3.0 4.3 15 400 1.6 3.6 1.91x2.91 2.7 9.0 n/a n/a D
240 or 1.30 4 C
277 1.12 3 C
120 or 2.60 8 B
208 or 1.60 5 B
87211 240 or M250ML5AC3M500K CWA 280 1.30 290 4 44 PC1 3.0 4.3 15 400 1.6 3.6 1.91x2.91 2.7 9.0 n/a n/a B
277 or 1.20 3 C
480 0.70 2 C
MH 250 WATTS featuring Multi-5
Nom Dimensions Capacitor Ignitor
GE Max Open To tal Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Voltage Rating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 250 WATT M58 METAL HALIDE OR H37 MERCURY LAMPS - 4.75" Frame
120 or 2.50 8
208 or 1.40 5
87212 240 or M250ML5AC4M500K CWA 293 1.30 305 4 44 PC2 1.8 3.6 15 400 1.6 3.6 1.91x2.91 2.7 10.8 n/a n/a A
277 or 1.10 3
480 0.65 2
B
MAX
0.250 Dia Thru
2 Holes
0.250 Dia Thru
4 Holes
A
3.875˝
4.250˝
4.375˝4.750˝
MH 400-1000 WATTS
CORE & COIL ELECTRONIC BALLASTS
METAL HALIDE LAMPS
MH 400 WATTS featuring Multi-5
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current VoltageRating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 400 WATT M59 METAL HALIDE OR H33 MERCURY LAMP
86803 480-120 M40048TAC4M500K CWA 458 1.00 300 5 19 PC2 2.0 3.9 24 400 1.8 3.6 1.91x2.91 3.1 11.2 n/a n/a E
120 or 4.00 10 C
86814 208 or M400MLTAC4M500K CWA 458 2.30 300 821 PC2 2.0 3.9 24 360 1.8 3.6 1.91x2.91 3.1 11.2 n/a n/a D
240 or 2.00 5 D
277 1.70 5 E
120 or 4.00 10 E
208 or 2.30 8 D
87212 240 or M400ML5AC4M500K CWA 458 2.00 300 5 44 PC2 2.0 3.9 24 400 1.8 3.6 1.91x2.91 3.1 11.2 n/a n/a E
277 or 1.70 5 D
480 1.00 5 E
DIMENSIONS
BRef. Dwg. L W M S
PC 2 5.25” 1.25” 4.60” 0.25”
PC3 7.75” 2.75” 6.10” 0.25”
M
L
WS
Bracket
REFERENCE DRAWING PC2 REFERENCE DRAWING PC3
B
MAX
0.250 Dia Thru
2 Holes
0.250 Dia Thru
4 Holes
A
3.875˝
4.250˝
4.375˝4.750˝
B
MAX
0.250 Dia Thru
2 Holes
0.250 Dia Thru
8 Holes
A
3.875˝
4.250˝4.375˝
5.375˝5.750˝
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Voltage Rating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 1000 WATT M47 METAL HALIDE OR H36 MERCURY LAMP
86650 480-120 M100048TAC5M500K CWA 1080 2.30 420 10 19 PC3 2.8 4.6 24 480 n/a n/a 1.91x2.91 3.9 22.0 n/a n/a C
120 or 9.20 20
86655 208 or M1000MLTAC5M500K CWA 1080 5.30 420 15 21 PC3 2.8 4.7 24 480 n/a n/a 1.91x2.91 3.9 22.0 n/a n/a D
240 or 4.60 10
277 4.00 10
120 or 9.00 20 F
208 or 5.20 15 B
87213 240 or M1000ML5AC5M500K CWA 1080 4.40 425 10 44 PC3 2.8 4.6 24 480 n/a n/a 1.91x2.91 3.9 22.0 n/a n/a B
277 or 3.90 10 B
480 2.30 10 B
MH 1000 WATTS featuring Multi-5
See pg. 5-6 for adjustable mounting brackets and
detailed bracket drawings.
DESCRIPTION SUFFIX *
For Ballast Only 000
For Bracket Only (see pg. 5-6) 200
For Capacitor Only (see pg. 5-6) 500
For Distributor Replacement Kit
(see pg. 5-12 thru 5-13) 500K
DESCRIPTION SUFFIX *
For Ballast Only 000
For Bracket Only (see pg. 5-6) 200
For Capacitor Only (see pg. 5-6) 500
For Distributor Replacement Kit
(see pg. 5-12 thru 5-13) 500K
5-19
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
5-18
transforming the power of light
MH 1500 WATTS
PULSE START
MH 175-320 WATTS
CORE & COIL ELECTRONIC BALLASTS
METAL HALIDE LAMPS
MH 1500 WATTS
DIMENSIONS
BRef. Dwg. L W M S
PC3 7.75” 2.75” 6.10” 0.25”
M
L
WS
Bracket
REFERENCE DRAWING PC3
B
MAX
0.250 Dia Thru
2 Holes
0.250 Dia Thru
8 Holes
A
3.875˝
4.250˝4.375˝
5.375˝5.750˝
Nom Dimensions Capacitor Ignitor
GE Max Open Total M ax UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Voltage Rating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 1500 WATT M48 METAL HALIDE LAMP
86693 480-120 M150048TAC5M500K CWA 1610 3.50 450 10 19 PC3 4.3 6.4 32 525 n/a n/a 1.97x3.66 3.9 29.5 n/a n/a E
120 or 14.00 40 F
86698 208 or M1500MLTAC5M500K CWA 1610 8.00 450 25 21 PC3 4.3 6.4 32 525 n/a n/a 1.97x3.66 3.9 30.0 n/a n/a E
277 7.00 20 F
See pg. 5-6 for adjustable mounting brackets and
detailed bracket drawings.
CORE & COIL ELECTRONIC BALLASTS
METAL HALIDE LAMPS
PULSE START MH 250-320 WATTS
DIMENSIONS
BRef. Dwg. L W M S
PC1 5.25” 1.25” 4.60” 0.25”
PC 2 5.25” 1.25” 4.60” 0.25”
M
L
WS
Bracket
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Voltage Rating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 250/320 WATT M138 OR M132METAL HALIDE PULSE START LAMP
120 or 2.40 8
86935 208 or P250MLTAC4M500K CWA 285 1.45 296 511 PC2 1.3 3.2 14 400 1.6 3.6 1.91x2.91 2.7 9.3 MH350-1 10 A
240 or 1.20 5
277 1.06 3
86926 480-120 P25048TAC4M500K CWA 285 0.62 290 2 13 PC2 2.0 3.8 14.0 400 1.6 3.6 1.91x2.91 2.7 11.3 MH350-1 10 A
120 or 4.10 8
86959 208 or P320MLTAC4M500K CWA 365 2.50 292 711 PC2 2.0 3.8 20.5 400 1.8 3.6 1.91x2.91 3.1 11.2 MH350-1 10 A
240 or 2.00 5
277 1.85 5
120 or 3.25 8
86968 277 or P320TRIAC4M500K CWA 365 1.40 265 4 15 PC2 1.7 3.7 24.5 300 1.6 3.6 1.91x2.91 2.7 11.0 MH350-1 10 A
340 1.15 3
86952 480-120 P32048TAC4M500K CWA 405 1.06 292 3 13 PC2 2.0 3.8 20.5 400 1.8 3.6 1.91x2.91 3.1 11.3 MH350-1 10 A
REFERENCE DRAWING PC1
B
MAX
0.250 Dia Thru
2 Holes
0.199 Dia Thru
4 Holes
A
2.438˝
2.812˝
3.500˝3.938˝
PULSE START MH 175 WATTS
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Vltg Rtg Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 175 WATT M137 METAL HALIDE PULSE START LAMP
120 or 1.80 5 A
86885 208 or P175MLTAC3M500K CWA 208 1.10 255 311 PC1 2.1 3.6 10 400 1.6 2.7 1.31x2.16 3.9 6.8 MH350-1 10 B
240 or 0.90 3 B
277 0.78 2 B
86876 480-120 P17548TAC3M500K CWA 210 0.45 255 2 13 PC1 2.6 4.1 10 400 1.6 2.7 1.31x2.16 3.9 7.0 MH350-1 10 C
REFERENCE DRAWING PC2
B
MAX
0.250 Dia Thru
2 Holes
0.250 Dia Thru
4 Holes
A
3.875˝
4.250˝
4.375˝4.750˝
DESCRIPTION SUFFIX *
For Ballast Only 000
For Bracket Only (see pg. 5-6) 200
For Capacitor Only (see pg. 5-6) 500
For Distributor Replacement Kit
(see pg. 5-12 thru 5-13) 500K
DESCRIPTION SUFFIX *
For Ballast Only 000
For Bracket Only (see pg. 5-6) 200
For Capacitor Only (see pg. 5-6) 500
For Distributor Replacement Kit
(see pg. 5-12 thru 5-13) 500K
5-21
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
5-20
transforming the power of light
PULSE START
MH 350-400 WATTS
PULSE START
MH 750 WATTS
CORE & COIL ELECTRONIC BALLASTS
METAL HALIDE LAMPS
DIMENSIONS
REFERENCE DRAWING RX1
BRef. Dwg. L W M S
PC 2 5.25” 1.25” 4.60” 0.25”
RX1 4.00” 0.75” 3.35” 0.25”
M
L
WS
Bracket
REFERENCE DRAWING PC2
B
MAX
0.250 Dia Thru
2 Holes
0.250 Dia Thru
4 Holes
A
3.875˝
4.250˝
4.375˝4.750˝
PULSE START MH 350-400 WATTS
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 350 WATT M131 METAL HALIDE PULSE START LAMP
120 or 4.10 10
86984 208 or P350MLTAC4M500K CWA 400 2.50 292 711 PC2 2.0 3.8 22 400 1.8 3.6 1.91x2.91 3.1 11.2 MH350-1 10 A
240 or 2.00 5
277 1.85 5
42692 277 P350277RCEM500K RX-NPF 377 3.80 277 8 1 RX1 1.5 3.2 22.5 280 — — — 6.8 MH350-1 10 A
RX-HPF 2.34 1.6 3.6 1.56x2.69 3.5
(1) 400 WATT M135 METAL HALIDE PULSE START LAMP
120 or 4.10 10
87008 208 or P400MLTAC4M500K CWA 458 2.50 292 711 PC2 2.0 3.8 24 400 1.8 3.6 1.91x2.91 3.1 11.2 MH350-1 10 D
240 or 2.00 5
277 1.85 5
86999 480-120 P40048TAC4M500K CWA 458 1.06 292 3 13 PC2 2.0 3.8 24 400 1.8 3.6 1.19x2.91 3.1 11.3 MH350-1 10 D
CORE & COIL ELECTRONIC BALLASTS
METAL HALIDE LAMPS
PULSE START MH 750 WATTS
DIMENSIONS
BRef. Dwg. L W M S
PC3 7.75” 2.75” 6.10” 0.25”
M
L
WS
Bracket
REFERENCE DRAWING PC3
B
MAX
0.250 Dia Thru
2 Holes
0.250 Dia Thru
8 Holes
A
3.875˝
4.250˝4.375˝
5.375˝5.750˝
See pg. 5-6 for adjustable mounting brackets and
detailed bracket drawings.
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 750 WATT M149 METAL HALIDE PULSE START LAMP
120 or 6.90 15
46934 208 or P750MLTAC5M500K CWA 810 4.00 400 811 PC3 2.8 4.6 24 480 n/a n/a 1.91x2.91 3.9 22.0 HPS750-1B 10 D
240 or 3.50 8
277 3.00 8
46936 480-120 P75048TAC5M500K CWA 810 2.00 400 6 13 PC3 2.8 4.6 24 480 n/a n/a 1.91x2.91 3.9 22.0 HPS750-1B 10 E
DESCRIPTION SUFFIX *
For Ballast Only 000
For Bracket Only (see pg. 5-6) 200
For Capacitor Only (see pg. 5-6) 500
For Distributor Replacement Kit
(see pg. 5-12 thru 5-13) 500K
DESCRIPTION SUFFIX *
For Ballast Only 000
For Bracket Only (see pg. 5-6) 200
For Capacitor Only (see pg. 5-6) 500
For Distributor Replacement Kit
(see pg. 5-12 thru 5-13) 500K
5-23
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
5-22
transforming the power of light
HPS 50 WATTS
HPS 100-150 WATTS
CORE & COIL ELECTRONIC BALLASTS
HIGH PRESSURE SODIUM LAMPS
HPS 70 WATTS
DIMENSIONS
BRef. Dwg. L W M S
PC1 5.25” 1.25” 4.60” 0.25”
1, 1a 4.00” 0.75” 3.35” 0.25”
M
L
WS
Bracket
REFERENCE DRAWING 1
.203" Dia Thru
4 Holes
0.594"
0.438"
B
A
2.188"
1.750"
2.625"
2.188"
1.750"
.203" Dia Thru
4 Holes
2.625"
2.188"
0.594"
0.438"
0.438"
2.188"
AB
REFERENCE DRAWING PC1
B
MAX
0.250 Dia Thru
2 Holes
0.199 Dia Thru
4 Holes
A
2.438˝
2.812˝
3.500˝3.938˝
See pg. 5-6 for adjustable mounting brackets and
detailed bracket drawings.
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 70 WATT S62 HIGH PRESSURE SODIUM lamp
86605 120 1233-142U0001 R-NPF 83 2.10 120 8111.3 2.6 — — — 2.3 HPS150-3A 3 A
1233-142W u R-HPF 1.30 5 1A 1a 1.3 2.7 28 120 1.6 2.7 n/a n/a 2.5 Permanently Attached
86456 480-120 S7048TLC3M500K HX-HPF 94 0.34 120 2 6 PC1 1.4 2.8 7 280 1.2 2.2 1.31x2.16 2.2 6.0 HPS150-3A 10 A
120 or 1.40 5 A
86587 208 or S70MLTLC3M500K HX-HPF 94 0.83 120 34PC1 1.4 2.7 7 280 1.2 2.2 1.31x2.16 2.2 4.1 HPS150-3A 10 B
240 or 0.72 3 B
277 0.62 2 B
HPS 50 WATTS
Nom Dimensions Capacitor Ignitor
GE Max Open Total M ax UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 50 WATT S68 HIGH PRESSURE SODIUM LAMP
120 or 1.24 5
87152 208 or S50MLTLC3M500K HX-HPF 64 0.59 120 34PC1 1.4 2.6 5 280 1.2 2.2 1.31x2.16 2.2 4.1 HPS150-3A 10 A
240 or 0.50 3
277 0.44 2
REFERENCE DRAWING 1a
CORE & COIL ELECTRONIC BALLASTS
HIGH PRESSURE SODIUM LAMPS
HPS 150 WATTS
DIMENSIONS
BRef. Dwg. L W M S
PC1 5.25” 1.25” 4.60” 0.25”
1, 1a 4.00” 0.75” 3.35” 0.25”
M
L
WS
Bracket
REFERENCE DRAWING 1
.203" Dia Thru
4 Holes
0.594"
0.438"
B
A
2.188"
1.750"
2.625"
2.188"
REFERENCE DRAWING 1a
1.750"
.203" Dia Thru
4 Holes
2.625"
2.188"
0.594"
0.438"
0.438"
2.188"
AB
REFERENCE DRAWING PC1
B
MAX
0.250 Dia Thru
2 Holes
0.199 Dia Thru
4 Holes
A
2.438˝
2.812˝
3.500˝3.938˝
See pg. 5-6 for adjustable mounting brackets and
detailed bracket drawings.
1
Also can be used on a 277 Volt line in conjunction with step-down transformers.
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 150 WATT S55 HIGH PRESSURE SODIUM LAMP
86606 120 11233-154U001 R-NPF 171 4.40 120 15 1 1 2.0 3.0 — — — 3.2 HPS150-3 3 A
1233-154W u R-HPF 3 2.40 8 1A 1a 2.0 3.4 52 240 1.8 3.6 2.12 2.9 3.5 Permanently Attached
87087 480-120 S15048TLC3M500K HX-HPF 189 0.72 120 3 4A PC1 3.0 4.5 14 280 1.6 2.7 1.56x2.69 2.7 8.7 HPS150-3A 10 D
120 or 3.00 10 C
87094 208 or S150MLTLC3M500K HX-HPF 189 1.65 120 54PC1 2.4 3.7 14 280 1.6 2.7 1.56x2.69 2.7 7.0 HPS150-3A 10 C
240 or 1.45 5 B
277 1.25 5 C
HPS 100 WATTS
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 100 WATT S54 HIGH PRESSURE SODIUM LAMP
87068 480-120 S10048TLC3M500K HX-HPF 135 0.57 122 2 6 PC1 2.0 3.3 10 280 1.2 2.7 1.31x2.16 2.7 6.5 HPS150-3A 10 B
120 or 2.20 8 B
87074 208 or S100MLTLC3M500K HX-HPF 122 1.40 120 54PC1 2.0 3.3 10 280 1.2 2.7 1.31x2.16 2.7 5.9 HPS150-3A 10 A
240 or 1.10 5 A
277 0.95 3 A
DESCRIPTION SUFFIX *
For Ballast Only 000
For Bracket Only (see pg. 5-6) 200
For Capacitor Only (see pg. 5-6) 500
For Distributor Replacement Kit
(see pg. 5-12 thru 5-13) 500K
DESCRIPTION SUFFIX *
For Ballast Only 000
For Bracket Only (see pg. 5-6) 200
For Capacitor Only (see pg. 5-6) 500
For Distributor Replacement Kit
(see pg. 5-12 thru 5-13) 500K
5-25
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
5-24
transforming the power of light
HPS 250-400 WATTS
HPS 400-1000 WATTS
CORE & COIL ELECTRONIC BALLASTS
HIGH PRESSURE SODIUM LAMPS
HPS 250 WATTS featuring Multi-5
DIMENSIONS
BRef. Dwg. L W M S
PC 2 5.25” 1.25” 4.60” 0.25”
M
L
WS
Bracket
REFERENCE DRAWING PC2
B
MAX
0.250 Dia Thru
2 Holes
0.250 Dia Thru
4 Holes
A
3.875˝
4.250˝
4.375˝4.750˝
See pg. 5-6 for adjustable mounting brackets and
detailed bracket drawings.
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Voltage Rating Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 250 WATT S50 HIGH PRESSURE SODIUM LAMP
120 or 2.50 8
87121 208 or S250MLTAC4M500K CWA 300 1.50 185 511PC2 1.7 3.7 35 280 1.8 3.6 1.91x2.91 3.1 10.3 HPS400-3A 10 A
240 or 1.30 4
277 1.10 4
120 or 2.50 8
208 or 1.43 5
87214 240 or S250ML5AC4M500K CWA 300 1.25 200 4 46 PC2 2.0 3.8 35 280 1.8 3.6 1.91x2.91 3.1 10.3 HPS400-3 10 A
277 or 1.10 4
480 0.65 4
HPS 400 WATTS featuring Multi-5
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Voltage Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP - 4 3/4” FRAME
87198 480-120 S40048TAC4M500K CWA 465 1.00 190 5 13 PC2 2.3 4.1 55 240 1.8 3.6 1.91x2.91 3.5 14.5 HPS400-3A 10 D
120 or 3.90 15 D
87164 208 or S400MLTAC4M500K CWA 465 2.25 190 811 PC2 2.3 4.1 55 240 1.8 3.6 1.91x2.91 3.5 14.5 HPS400-3A 10 D
240 or 1.95 8 C
277 1.70 5 D
120 or 3.90 15 B
208 or 2.25 8 D
87215 240 or S400ML5AC4M500K CWA 465 1.95 190 8 46 PC2 2.3 4.1 55 240 1.8 3.6 1.91x2.91 3.5 15.5 HPS400-3 10 C
277 or 1.70 5 C
480 1.00 5 B
CORE & COIL ELECTRONIC BALLASTS
HIGH PRESSURE SODIUM LAMPS
HPS 400 WATTS featuring Multi-5
DIMENSIONS
BRef. Dwg. L W M S
PC3 7.75” 2.75” 6.10” 0.25”
M
L
WS
Bracket
REFERENCE DRAWING PC3
B
MAX
0.250 Dia Thru
2 Holes
0.250 Dia Thru
8 Holes
A
3.875˝
4.250˝4.375˝
5.375˝5.750˝
See pg. 5-6 for adjustable mounting brackets and
detailed bracket drawings.
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP - 5 3/4" Frame
87206 480-120 S40048TAC5M500K CWA 465 1.00 190 5 13 PC3 2.3 4.2 48 280 1.8 4.6 1.91x2.91 3.9 15.5 HPS400-3A 10 D
120 or 3.90 15
87175 208 or S400MLTAC5M500K CWA 467 2.25 195 811 PC3 2.3 4.1 48 280 1.8 4.6 1.91x2.91 3.9 15.5 HPS400-3A 10 D
240 or 1.95 8
277 1.70 5
120 or 3.90 15
208 or 2.25 8
87217 240 or S400ML5AC5M500K CWA 468 1.95 1.95 8 46 PC3 2.5 4.3 48 280 1.8 4.6 1.91x2.91 3.9 15.5 HPS400-3 10 C
277 or 1.70 5
480 1.00 5
HPS 1000 WATTS featuring Multi-5
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 1000 WATT S52 HIGH PRESSURE SODIUM lamp
87048 480-120 S100048TAC5M500K CWA 1100 2.40 440 8 13 PC3 3.8 6.0 26 525 n/a n/a 1.91x2.91 4.3 25.0 HPS1000-4B 15 D
120 or 9.50 20
87056 208 or S1000MLTAC5M500K CWA 1100 5.50 440 15 11 PC3 3.8 5.6 26 525 n/a n/a 1.91x2.91 4.25 26.0 HPS1000-4B 15 C
240 or 4.80 10
277 4.10 10
120 or 9.10 20
208 or 5.40 15
87218 240 or S1000ML5AC5M500K CWA 1.48 4.60 435 10 46 PC3 3.8 5.5 26 525 n/a n/a 1.91x2.91 4.25 26.0 HPS1000-4 15 D
277 or 4.10 10
480 2.40 8
DESCRIPTION SUFFIX *
For Ballast Only 000
For Bracket Only (see pg. 5-6) 200
For Capacitor Only (see pg. 5-6) 500
For Distributor Replacement Kit
(see pg. 5-12 thru 5-13) 500K
DESCRIPTION SUFFIX *
For Ballast Only 000
For Bracket Only (see pg. 5-6) 200
For Capacitor Only (see pg. 5-6) 500
For Distributor Replacement Kit
(see pg. 5-12 thru 5-13) 500K
5-27
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
5-26
transforming the power of light
MERCURY
100-400 WATTS
MH 75-150 WATTS
CORE & COIL ELECTRONIC BALLASTS
MERCURY LAMPS
MERCURY 100 WATTS
Nom Dimensions Capacitor Ignitor
GE Max Open Total Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 100 WATT H38 or H44 MERCURY LAMP
120 or 1.05 3
86519 208 or H100MLTAC3M500K CWA 125 0.60 250 221 PC1 1.3 2.5 10 280 1.4 2.7 1.31x2.16 2.7 4.0 n/a n/a A
240 or 0.52 2
277 0.45 2
MERCURY 175 WATTS
Nom Dimensions Capacitor Ignitor
GE Max Open To tal Max UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 175 WATT H39 MERCURY LAMP
120 or 1.75 5
86527 208 or H175MLTAC3M500K CWA 202 1.00 235 321 PC1 1.6 2.9 17.5 300 1.6 3.6 1.56x2.69 3.1 5.2 n/a n/a A
240 or 0.86 3
277 0.75 2
MERCURY 400 WATTS
DIMENSIONS
BRef. Dwg. L W M S
PC1 5.25” 1.25” 4.60” 0.25”
PC 2 5.25” 1.25” 4.60” 0.25”
M
L
WS
Bracket
See pg. 5-6 for adjustable mounting brackets and
detailed bracket drawings.
B
MAX
0.250 Dia Thru
2 Holes
0.199 Dia Thru
4 Holes
A
2.438˝
2.812˝
3.500˝3.938˝
REFERENCE DRAWING PC1 REFERENCE DRAWING PC2
B
MAX
0.250 Dia Thru
2 Holes
0.250 Dia Thru
4 Holes
A
3.875˝
4.250˝
4.375˝4.750˝
Nom Dimensions Capacitor Ignitor
GE Max Open Total M ax UL
Product Input Catalog*Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt Catalog Distance Bench
Code Volts Number Type Input Current Vltg Rtng Dia Dwg A B Mfd Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise
(1) 400 WATT H33 MERCURY LAMP
120 or 3.90 10
86542 208 or H400MLTAC4M500K CWA 440 2.22 245 821 PC2 1.6 3.4 35 240 1.6 3.6 1.91x2.91 3.1 9.5 n/a n/a C
240 or 1.92 5
277 1.68 5
F-CAN BALLASTS
METAL HALIDE LAMPS
Nom Dimensions Max
GE Max Open Dist Certifications
Product Input Catalog Circuit Input Input Circuit Fuse Wir Overall Case Mtg Total To Sound
Code Volts Number Type Watts Current Vltg Rtng Dia Length Length Dim Weight Lamp (ft) Rating UL CSA
(1) 70 WATT M85 METAL HALIDE (with built-in ignitor)
86575 120 or 11210-277C-TC7HX-HPF 98 2.00 250 6 34 11.75 10.55 11.10 11.0 20 B Yes Yes
277 0.90 3
(1) 70 WATT M98 METAL HALIDE (with built-in ignitor)
86578 120 or 11210-506C-TC22 HX-HPF 90 2.00 250 6 34 11.75 10.55 11.10 11.0 20 B Yes Yes
277 0.90 3
(1) 100 WATT M90 METAL HALIDE (with built-in ignitor)
86574 120 or 11210-239C-TC HX-HPF 125 2.20 250 8 34 11.75 10.55 11.10 11.0 20 B Yes Yes
277 1.00 4
MH 70-100 WATTS
Case Length
Overall Length
Mounting
Height
Mounting
Width
Hole
Width
REFERENCE DRAWING
FOR F-CAN
Mounting Bracket Assemblies
4.500"
0.562"
0.406"
4.000"
1.000" 2.000"
0.250" Dia.
Mounting Bracket Assemblies
1.750"
1.437"
2.562"
1.500"
2.000"
0.218" Dia.
Tee-Pee Lead Wire Covers
Splice Box
Splice Box
2.812"
3.000"
2.000"
2.531"
0.850" Dia.
Knockouts
5 Places
Embossed Dimples
2 Places
0.297" Dia.
Mounting Holes
2 Places
Catalog Number
2-BMB-1.
Available for the remote
installation of ballasts.
Each assembly consists of
two (2) mounting brackets,
four (4) screws, four (4)
washers and four (4) nuts.
Catalog Number SB-4.
Ref. part #001-2009
For use with all F-Can Ballasts.
It is easily installed on the
anchor bracket provided on
each F-Can ballast. It contains
five (5) 7/8" diameter knockouts.
Catalog Number TP5. Ref. part #001-2013.
For use where ballast is attached to the
surface of an enclosure or raceway.
Tee-Pee Lead Wire Covers
F-CAN BALLASTS OPTIONAL ACCESSORIES
7 This ballast may also be used with (1) 70 watt S88 High Pressure Sodium lamp.
22 M98 Designates Venture Lighting catalog numbers MH70/4/MED, C/4/MED or MS70/C/84/MED/W
DESCRIPTION SUFFIX *
For Ballast Only 000
For Bracket Only (see pg. 5-6) 200
For Capacitor Only (see pg. 5-6) 500
For Distributor Replacement Kit
(see pg. 5-12 thru 5-13) 500K
5-29
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
HID CONTROLLERS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
5-28
transforming the power of light
MH/PSMH
175-400 WATTS &
HPS 70 WATTS
F-CAN BALLASTS
METAL HALIDE & PULSE START METAL HALIDE LAMPS
MH AND PSMH 175-400 WATTS
Nom Dimensions Max
GE Max Open Dist Certifications
Product Input Catalog Circuit Input Input Circuit Fuse Wir Overall Case Mtg Total To Sound
Code Volts Number Type Watts Current Vltg Rtng Dia Length Length Dim Weight Lamp (ft) Rating UL CSA
(1) 175 WATT M57 METAL HALIDE OR H39 MERCURY LAMP
86563 120 or 1110-245SC-TC000I CWA 205 1.75 300 5 34 14.30 13.15 13.75 14.0 * B Yes Yes
277 0.75 3
(1) 250 WATT M58 METAL HALIDE OR H37 MERCURY LAMP
86564 120 or 1110-246C-TC 8c CWA 295 2.50 280 8 34 16.65 15.55 16.10 17.5 * C Yes Yes
277 1.10 4
(1) 400 WATT M59 METAL HALIDE OR H33 MERCURY LAMP
42670 120 or 1110-247SC-TC CWA 460 3.90 300 10 34 19.25 18.05 18.60 23.0 * C Yes Yes
277 1.70 5
80728 120 or 1111-247SC-TC 23 CWA 460 3.90 300 10 36 14.30 13.15 13.75 14.0 * B Yes Yes
277 1.70 5
8c This ballast can be used with a MH200 ignitor to operate (1) 250 watt M103 lamp. Consult Universal for instructions.
23 Two of these ballasts are required to operate the lamp. Electrical data is for two ballasts, except for “Sound Rating,” which is for each ballast.
* Refer to Page 5-4.
F-CAN BALLASTS OPTIONAL ACCESSORIES
F-CAN BALLASTS
METAL HALIDE LAMPS
Nom Dimensions Max
GE Max Open Dist Certifications
Product Input Catalog Circuit Input Input Circuit Fuse Wir Overall Case Mtg Total To Sound
Code Volts Number Type Watts Current Vltg Rtng Dia Length Length Dim Weight Lamp (ft) Rating UL CSA
(1) 70 WATT S62 HIGH PRESSURE SODIUM (with built-in starter)
86596 120 or 12210-237C-TC0001 HX-HPF 97 1.60 140 534 11.75 10.55 11.10 9.2 10 B Yes Yes
277 0.70 2
HPS 70 WATTS
Case Length
Overall Length
Mounting
Height
Mounting
Width
Hole
Width
REFERENCE DRAWING
FOR F-CAN
Mounting Bracket Assemblies
4.500"
0.562"
0.406"
4.000"
1.000" 2.000"
0.250" Dia.
Mounting Bracket Assemblies
1.750"
1.437"
2.562"
1.500"
2.000"
0.218" Dia.
Tee-Pee Lead Wire Covers
Splice Box
Splice Box
2.812"
3.000"
2.000"
2.531"
0.850" Dia.
Knockouts
5 Places
Embossed Dimples
2 Places
0.297" Dia.
Mounting Holes
2 Places
Catalog Number
2-BMB-1 (PC #86624)
Available for the remote
installation of ballasts.
Each assembly consists of
two (2) mounting brackets,
four (4) screws, four (4)
washers and four (4) nuts.
Catalog Number SB-4.
Ref. part #001-2009
For use with all F-Can Ballasts.
It is easily installed on the
anchor bracket provided on
each F-Can ballast. It contains
five (5) 7/8" diameter knockouts.
Catalog Number TP5. Ref. part #001-2013.
For use where ballast is attached to the
surface of an enclosure or raceway.
Tee-Pee Lead Wire Covers
SOLODUAL-LEVEL HID SWITCHING CONTROLLER
Application
The SOLO
dual level HID controller simplifies the
complex. Providing single fixture control to ensure
maximum ROI. The SOLO
is capable of interfacing
with metal halide, pulse start, and high-pressure sodi-
um fixtures ranging from 175 watts to 1,650 watts.
The SOLO
reduces fixture power up to 50% in
applications such as warehouse and manufacturing
facilities.
Key Features
• For use with CWA (Constant Wattage Auto-
Transformer) ballasts only
• Lamp Type Controlled: (Refer to ordering informa-
tion when selecting control module)
175W to 1,650W Metal Halide
175W to 720W Pulse Start Halide
250W to 1,000W High Pressure Sodium
• Initial Lamp Warm Up Time: 15 minutes
• Warm Up Time If Lamp Goes Out: 15 minutes
after lamp current is detected
• Lamp Switching: Solid state switching and
microprocessor watch dog provides reliable zero
cross voltage switching from low to high and
zero cross current switching from high to low.
Inrush protected.
• Continuous Dim Lamp Protection: The micro-
processor monitors continuous dim time of the
lamp. If lamp is dimmed continuously for 24
hours, lamp is automatically cycled to full power
for 15 minutes to increase lamp life.
• Capacitor: Series dim capacitor is mounted inside
the SOLO
module. Capacitor value is selected
based on ballast manufacturing specifications.
• Sensor Self-adjusting: Digital microprocessor
constantly adjusts sensitivity for optimum
performance.
• Sensor Optics: 9.6 square inches of optical lens @
2.15" focal length. (For long range sensing appli-
cations, the greater optical area and longer focal
length increases performance.)
• Sensor Range Pattern: (4) interchangeable lens
options
• Laser alignment: Allows accurate aiming of
sensor pattern to within +/- 2 degrees
• Sensor Timer Settings: 2-, 4-, 8-,16-, and
64-minute and 10-second test modes
• Force Dim Option: After lamp warm up, sensor is
disabled and lamp will dim continuously.
Continuous dim protection is still active.
• Self Diagnostics Test Button: Momentary push
button initiates self-diagnostic to verify SOLO
is
functioning properly.
• User Interface: 4 dip switches and self diagnostic
push button
• Mounting: 3/4" Threaded pipe mounting adapter
with security screw. Mount such that sensor lens
is even or below fixture reflector.
• Power Cord: 6' power cord with Myzer plug.
• Operating Temperature Range: (Indoor use only):
-22ºF to +149ºF (-30ºC to +65ºC)
•Weight: Less than 3 lbs. (without dim capacitor
installed)
• Dimensions: 13.25"H x 5.5"W x 2.6"D
(33.6 x 14.0 x 6.6 cm)
• Construction: Rugged, high impact, injection-
molded plastic.
• UL and CUL listed
• Warranty: Five-year limited
SOLOInstallation
Integrated HID Dual-level Switching Controller and Sensor
5-31
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
IGNITORS
For more information, visit www.gelighting.com
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
5-30
transforming the power of light
PART NUMBERS &
ACCESSORIES
SOLODUAL LEVEL HID SWITCHING CONTROLLER
Part Numbers and Accessories
GE Product
Code Model Wattage Controlled Table
41461 LB-1 175W Metal Halide
175W, 200W Pulse Start Metal Halide
41462 LB-2 250W, 320W, 350W, 400W Metal Halide
250W, 320W, 350W, 400W, 450W Pulse Start Metal Halide
250 W High Pressure Sodium (HPS)
400 W High Pressure Sodium (HPS) (Maximum operating temperature @ 55°C)
41463 LB-3 1,500W, 1,650W Metal Halide (Maximum operating temperature @ 55°C)
1,000W Metal Halide (Maximum operating temperature @ 65°C)
740W, 1000W Pulse Start Metal Halide (Maximum operating temperature @ 55°C)
600W, 1,000W High Pressure Sodium (HPS) (Max. operating temperature @ 65°C)
Models
41461 LB-1 SoloTM
TBD LB-1-MS SoloTM with MyzerSTART option
41462 LB-2 SoloTM
TBD LB-2-MS SoloTM with MyzerSTART option
41463 LB-3 SoloTM
TBD LB-3-MS SoloTM with MyzerSTART option
41304 LB-1-EXTP1 SoloTM with 4 Pin Low Voltage Interface
TBD LB-1-MS-EXTP2 SoloTM with MyzerSTART option with 4 Pin Low Voltage Interface
41324 LB-2-EXTP1 SoloTM with 4 Pin Low Voltage Interface
TBD LB-2-MS-EXPT2 SoloTM with MyzerSTART option with 4 Pin Low Voltage Interface
41328 LB-3-EXPT1 SoloTM with 4 Pin Low Voltage Interface
TBD LB-3-MS-EXTP2 SoloTM with MyzerSTART option with 4 Pin Low Interface
Lens
41479 LB-Lens 15 Lens 15, Aisle Lens, 1.5 x .23
41481 LB-Lens 10 Lens 10, Aisle Lens, 1.0 x .23
41277 LB-Lens 07 Lens 07, Aisle Lens, .70 x .16
41413 LB-Lens 0806 Lens 0806, Area Lens, .80 x .60
Accessories
41502 LB-LAT-1 Laser Alignment Tool
41292 LB-CSR-10 Cable Strain Relief, 10 Pack
41500 LB-KIT-1 Conversion Hardware Kit non-Myzer Port HID Fixtures
41283 MP-C2P-10 MyzerPORT Bypass Shorting Plug, 10 pack
41290 MP-BP-10 MyzerPORT Bypass Shorting Plug, 10 pack
Replacement Parts
41486 DC-6 Power Cable, 6 foot
41429 LB-LAT-SW Laser Alignment Tool on/off Switch
41476 LB-COVER-1 Capacitor and Wiring Compartment Cover
41402 LB-MOUNT-1 3/4" Threaded Mounting Adapter
41472 LB-CAP-WIRES Two (2) Cap Connection Wires with Quick Disconnects
TBD MPNA-C2P-100 MyzerPORT Connector Nipple adapter, 100 pack
41390 LB-FPP-10 G2, 4 pin EXTP1-Port Plug, 10 pack
* All orders require a completed HID capacitor sign-off sheet. Contact your GE representiative for more details.
IGNITORS
GE Product Code Catalog Number Description
STANDARD IGNITORS
Metal halide
86864 86864001I For 35 watt M130, 50 watt M110, 70 watt M98, 100 watt M90 or M92, or 150 watt M102 lamps.
HIGH PRESSURE SODIUM
86635 86635001I For lamps of 150 watts or less except 150 watt S56.
86641 86641001I For lamps from 200 to 400 watts and 150 watt S56 with CWA ballasts.
GE Long
Product Lamp ANSI Circuit Standard Auto Instant Distance
Code Watts Code Type Ignitors Shutoff Restrike Ignitors
HIGH PRESSURE SODIUM IGNITORS
86635 35 S76 Reactor HPS 150-3A HPS 150-45B HPS 150-5B HPS 150-4A
86635 50 S68 Reactor, HX HPS 150-3A HPS 150-45B HPS 150-5B HPS 150-4A
86635 70 S62 Reactor, HX HPS 150-3A HPS 150-45B HPS 150-5B HPS 150-4A
86635 100 S54 Reactor, HX HPS 150-3A HPS 150-45B HPS 150-5B HPS 150-4A
86635 150 S55 Reactor, HX HPS 150-3A HPS 150-45B HPS 150-5B HPS 150-4A
86641 150 S56 CWA HPS 400-3A HPS 400-45B HPS 400-4A
86641 250 S50 CWA HPS 400-3A HPS 400-45B HPS 400-4A
86641 400 S51 CWA HPS 400-3A HPS 400-45B HPS 400-4A
GE Long
Product Lamp ANSI Circuit Standard Auto Distance
Code Watts Code Type Ignitors Shutoff Ignitors
METAL HALIDE IGNITORS
86864 35 M130 Reactor MH 100-3A MH 100-5A
86864 50 M110 HX MH 100-3A MH 100-5A
86864 70 M98 HX MH 100-3A MH 100-35B MH 100-5A
86864 100 M90 Reactor MH 100-3A MH 100-35B MH 100-5A
86864 100 M90 CWA MH 100-3A MH 100-35B MH 100-5A
86864 150 M102 HX MH 100-3A MH 100-35B MH 100-5A
Standard Ignitors
Standard Ignitors are supplied with all High
Pressure Sodium and Metal Halide ballasts requir-
ing ignitors. These ballasts are supplied with an
appropriate external ignitor unless the ignitor is
permanently attached to or built into the ballast.
Instant Restrike Ignitors
An Instant Restrike Ignitor generates multiple
pulses to restrike a lamp arc after a brief power
interruption has extinguished it, without the typi-
cal 3-minute cool-down time. A Standard Ignitor
cannot restrike an arc until the lamp has had
time to sufficiently cool. Even though an Instant
Restrike Ignitor can reinitiate the lamp arc imme-
diately upon restoration of power, the lamp is
still subject to warmup. The following chart is
based on an S55 lamp.
1 second 2 seconds 87% 35 seconds
5 seconds Instant 83% 70 seconds
15 seconds Instant 76% 130 seconds
30 seconds Instant 62% 190 seconds
1 minute Instant 46% 255 seconds
Cold Start Instant 36% 360 seconds
Time Lamp Is Restrike Light Output Lamp Warmup
Extinguished Time On Reignition Time
Plug Replaceable Ignitors
Incorporates terminals and a separate mounting
base to simplify construction and replacement.
Long Distance Ignitors
Long Distance Ignitors are used in situations
where an ignitor must be mounted further from the
lamp than is recommended for a standard ignitor.
The maximum lamp to ignitor distance for these
ignitors is 50 feet, which may vary depending on
the type of lamp, ballast, fixture, and wiring.
Automatic Shutoff Ignitors
In the event of a lamp failure, a Standard Ignitor
will continue to pulse, trying to start the lamp. This
may reduce the life of the ignitor. An Automatic
Shutoff Ignitor will apply pulses for 10 to 12 min-
utes and then deactivate if a lamp arc cannot be
initiated. Resetting the ignitor is accomplished by
momentarily interrupting the power to the ballast.
For this reason, these ignitors are not recommended
for use on unswitched circuits.
Shutoff Devices
Ignitor Accessory (IA) devices can be used to
convert a Standard Ignitor into an Automatic Shutoff
Ignitor. Simply match the Shutoff Device catalog
number on page 5-78 with the Standard Ignitor
that is supplied with the ballast. Using the IA device
with the Standard Ignitor eliminates the need to
buy a separate Automatic Shutoff Ignitor.
HIGH INTENSITY DISCHARGE
(HID) BALLASTS
WIRING DIAGRAMS
5-32
transforming the power of light
WIRING DIAGRAMS
Line
(Black)
Lamp
(Blue)
Com
1
2
3
To Lamp Shell
STARTER
SF
Line
(Black)
Lamp Eyelet
REACTOR
APACITOR**
(Blue)
Common
(White)
Common
(White)
STARTER
Cap Cap
(Black)
Lamp Eyelet
(Blue)
Com
(Yellow)
1
2
3
3
To Lamp Shell
STARTER
(Yellow)
240V
277V
208V
120V
Cap Cap
(Black)
Lamp Eyelet
(Blue)
Com
(Yellow)
1
2
3
3
To Lamp Shell
STARTER
(Yellow)
277V
347V
120V
Line
Cap Cap
(White) (Black)
Lamp Eyelet
(Blue)
Com
(White)
1
2
3
3
To Lamp Shell
STARTER
Lamp Eyelet
(Red) 1
2
33
277V
240V
208V
120V
Com
(Yellow)
Com
(Yellow)
STARTER
Cap
(Red)
Cap
(Red)
(Red)
(Brown)
(Yellow)
DIAGRAM 1 DIAGRAM 1A DIAGRAM 4
DIAGRAM 6 DIAGRAM 11DIAGRAM 4A
DIAGRAM 15 DIAGRAM 19DIAGRAM 13
Lamp Eyelet
(Red)
1
2
3
3
347V
277V
120V
Com
(White)
Com
(White)
STARTER
Cap
(Red)
Cap
(Red)
Lamp Eyelet
(Red)
1
2
3
3
347V
277V
120V
Com
(White)
Com
(White)
STARTER
Cap
(Red)
Cap
(Red)
PERMISSIBLE
Com (Yellow)
or (White)
Com (Yellow)
or (White)
Cap
(Red)
Line
120V (AUX)
INC LAMP
W MAX
Com
(Yellow)
Com
(Yellow)
Cap
(Red)
277V
240V
208V
120V
277V or 347V Black
or 120V
Black/Yellow
White
Red
Insulate Unused Input
Lead for 300 Volts.
BALLAST
White
277V Black
Red Red Black or
Yellow
B
A
L
L
A
S
T
or 120V Black/Yellow
B
A
L
L
A
S
T
Separately Insulate Unused Input
Lead for 300 Volts
DIAGRAM 21 DIAGRAM 34 DIAGRAM 36
DIAGRAM 46DIAGRAM 44
6-1
For more information, visit www.gelighting.com
GLOSSARY
GLOSSARY
AC (Alternating Current) - Current which passes from the generator in
one direction and then the other, alternately.
ANSI (American National Standards Institute) - Non-profit
organization that generates voluntary product performance standards for
many U.S. industries. ANSI Standards C82.1 applies to electromagnetic
ballasts.
Arc - Intense luminous discharge formed by the passage of electric current
across a space between electrodes.
Auto Rest Shutdown Circuit - Circuit senses lamp end life and will
automatically shut off power to the lamp(s). When a new lamp is insert-
ed in the socket, the ballast resets, and turns on the lamp automatically.
Some shutdown circuits require the power to be interrupted before a
new lamp will re-light.
Ballast - Device for starting and regulating fluorescent and high intensity
discharge lamps.
Ballast Efficacy Factor (BEF) - Value used to evaluate various lighting
systems based on light output and power input. The BEF can only be
used to compare systems operating the same type and quantity of
lamps.
Ballast Factor (BF) - Measure of light output from lamp operated by
commercial ballast as compared to a laboratory standard reference bal-
last. Ballast Factor .94 means ballast produces 94% of light produced by
ANSI C82.2 reference ballast operating same lamps.
Ballast Hum - Sound generated by the vibration of laminations in the
electromagnetic field that transforms the current for discharge lamp use.
Ballast Losses - Power which is supplied to a ballast but is not converted
into lamp energy. Ballast loss is dissipated as heat.
Bottom Exit (BE) - A configuration with leads or a wire-trap on the
bottom or base of the ballast. This type of configuration is usually used
when the ballast is mounted onto a junction box plate.
Bottom Exit Studs (BES) - A configuration with screw studs mounted
on the base plate or bottom of the ballast. The screws are 3/8" inches
long with a #8-32 thread size (#8-32 nut). They are mounted on a two-
inch center. The studs are usually used to mount the ballast directly onto
a junction box plate.
Canadian Energy Standards - Indicates ballast complies with
Canadian Energy Standards and meets the requirements of
CAN/CSA C654-M91.
Canadian Standards Association (CSA) - Association that generates
product performance and safety standards for many Canadian
industries.
Capacitor - Device in ballast that stores electrical energy. Often used for
power factor correction and lamp regulation (see "Power Factor").
Cathode - See “Electrode”.
Centigrade (C) - Celsius temperature scale where 0°C=32°F.
Circle E - Designates a ballast meets or exceeds the requirements of Public
Law 100-357 establishing standards of efficiency.
Class P Thermal Protector - A switching device sensitive to current
and heat that automatically disconnects ballast if the temperature
exceeds UL temperature limitations.
Coil - Windings of copper or aluminum wire surrounding the steel core
in ballast.
Core - Component of electromagnetic ballast that is surrounded by the
coil. Core is comprised of steel laminations or solid ferrite material.
Core & Coil Ballast - Another term for an electromagnetic ballast.
Crest Factor (Lamp Current Crest Factor) - Ratio of peak lamp
current to RMS or average lamp operating current.
Efficacy - Lumen output per unit of power supplied to ballast (lumens per
watt).
Electrical Testing Laboratory (ETL) - Independent testing laboratory
that performs ballast tests and certifies accuracy of performance data.
Electrode - Metal filaments that emit electrons in a fluorescent lamp.
Negatively charged free electrons emitted by one electrode are attracted
to the positive electrode (anode), creating an electric current and arc
between electrodes.
Electromagnetic Ballast (Magnetic Ballast) - A ballast that uses a
“Core & Coil” assembly to transform electrical current to start and
operate fluorescent lamps.
EMI (Electromagnetic Interference) - Electrical interference (noise)
generated by electrical and electronic devices. Levels generated by high
frequency electronic devices are subject to regulation by Federal
Communications Commission (FCC).
Filament - Metal Tungsten wire coated with Barium Oxide that emits
electrons when voltage is applied.
Filament Voltage - Voltage applied to the lamp cathode.
Fluorescent Lamp - Gas filled lamp in which light is produced by the
interaction of electrons with phosphors lining the lamp's glass tube.
Foot Candles - Measure of light level on a surface being illuminated.
Defined as one lumen of light per one square foot of surface area.
Four-Pin Compact Fluorescent Lamps - Type of lamps that do not
have any starter built into the base of the lamp. Therefore, the ballast
has the starting circuit. Traditionally 4-pin lamps are designed to work
with electronic ballasts; however, GE offers magnetic ballasts to operate
some 4-pin lamps.
Frequency - Rate of alternation in an AC current. Expressed in cycles per
second or Hertz (Hz).
Harmonic - An integral multiple of the fundamental frequency (60 Hz)
that becomes a component of the current (see “Harmonic Distortion”).
Harmonic Distortion - Distortion of an AC waveform caused by
multiples of the fundamental frequency (harmonics). Odd triplet harmon-
ics (thirds, ninths, etc.) may result in large currents on the neutral line in
a four-wire Wye three-phase system.
Hertz (Hz) - Unit used to measure frequency of alteration of current or
voltage; cycles per second.
High Efficiency (Energy Saving) Electromagnetic Ballast -
Ballast with core & coils, designed to minimize ballast losses compared to
the “standard” ballast.
High Intensity Discharge (HID) Lamp - A lamp containing a filled
arc tube in which the active element becomes vaporized (a gaseous
state) and is discharged into the arc stream to produce light.
High Power Factor - A ballast whose power factor is corrected to
90% or greater by the use of a capacitor.
Incandescent Lamp - Lamp in which light is produced by a filament
heated by an electric current.
Input Voltage - Power supply voltage required for proper operation of
an arc discharge lighting ballast.
Inputs Watts - The total power input to the ballast which includes lamp
watts and ballast losses. The total power input to the fixture is the input
watts to the ballast or ballasts and is the value to be used when calculat-
ing cost of energy and air conditioning loads.
Instant Start Lamp - A fluorescent lamp with a single pin at each end.
The lamp is ignited by a high voltage without any filament heating.
GLOSSARY
GLOSSARY
transforming the power of light
6-2
Instant Start - Lamp starting method in which lamps are started by high
voltage input with no preheating of lamp filaments. Some rapid start
lamps are designed so that they may be instant started.
Laminations - Layers of steel, making up the "core" that is surrounded
by the coils in a core & coil ballast.
Lamp Current Crest Factor - See “Crest Factor”.
Lamp Filament - See “Electrode”.
Lamp Watts - Input power used to operate lamps.
Lumens/Watt - A measurement of white light produced by each output
watt.
Metal Cases - Case design used in both magnetic and electronic ballasts.
These ballasts are grounded once they are mounted to the fixture. They
meet all safety codes, some of which do not allow plastic in open plenum
areas.
National Electric Code (NEC) - A nationally accepted electrical
installation code to reduce the risk of fire, developed by the National Fire
Protection Association.
National Energy Standards for Fluorescent Ballasts - A
federal law enacted in 1988 that sets energy standards for ballasts consis-
tent throughout the United States.
NOM - Laboratory that sets safety standards for building materials, electrical
appliances and other products for Mexico.
Non-PCB Capacitor - Capacitor used in ballasts to help provide power
factor correction. Contains no polychlorinated biphenyls and meets EPA
requirements.
Normal Power Factor - Ballasts with power factor less than .90 and do
not incorporate any means of Power Factor Correction.
Parallel Lamp Operation - Refers to ballasts that employ multiple
output current paths from a single ballast to allow lamps to operate
independent of one another, allowing other lamps operated by the
ballast to remain lit should companion lamp(s) fail.
PCB (Polychlorinated Biphenyls) - Chemical pollutant formerly used
in ballast capacitors.
Potting - Material used to completely surround and cover components of
some magnetic and electronic ballasts. Potting compound fulfills func-
tions of protecting components, dampening sound, and dissipating heat.
Power Factor - Measurement of the relationship between the AC source
voltage and current. High power factor ballasts require less AC operating
current at the same wattage than an equivalent low power factor ballast.
Formula: Power Factor equals Input Watts divided by the product of Line
Volts times Line Amps (Volt Amps or VA).
Power Factor Corrected - Ballasts that incorporate a means of Power
Factor Correction but whose power factor is <90% and <50%.
Preheat Lamp - A fluorescent lamp in which the filament must be heated
by use of a starter before the arc is created. These lamps are typically
operated with electromagnetic ballasts.
Programmed Rapid Start - Lamp starting method which preheats the
lamp filaments while not allowing the lamp to ignite and then applies the
open circuit voltage (OCV) to start the lamp. The user may experience a
half- to one-second delay after turning on the lamps while the pre-heat-
ing takes place. This type of starting circuit keeps lamp end blackening to
a minimum and improves lamp life performance, especially in applications
where the lamps are frequently switched on and off.
Rapid Start Lamp - A fluorescent lamp with two pins at each end con
nected to the filament. The filaments are heated by the ballast to aid in
starting. Some rapid start lamps may be instant started without filament
heat, for example, the F32T8 lamp.
Rapid Start - Lamp starting method in which lamp filaments are heated
while open circuit voltage (OCV) is applied to facilitate lamp ignition.
Series Lamp Operation - Refers to ballasts that employ a single current
path passing through all lamps operated by the ballast. If one lamp
should fail, companion lamps operated by the same ballasts will also
extinguish or dim.
Standard Alternating Current Frequency in the United States -
60 Hertz (Hz) or 60 cycles per second.
Total Harmonic Distortion (THD) - The combined effect of Harmonic
Distortion on the AC waveform produced by a ballast or other device.
Expressed as a percentage. Excessive levels of THD can create large cur-
rents on the neutral line of a four-wire Wye three phase system. (See
“Harmonic Distortion”.)
Transients - High voltage surges through an electrical system caused by
lightning strikes to nearby transformers, overhead lines or the ground.
May also be caused by switching of motors or compressors, as well as by
short circuits or utility system switching. Can lead to premature ballast
failure.
Two-Pin Compact Fluorescent Lamps - Type of lamps that have the
glow bottle starter built into the base of the lamp. Traditionally 2-pin
lamps are designed to work with electromagnetic ballasts.
UL Underwriters' Laboratories, Inc.- Laboratory that sets safety
standards for building materials, electrical appliances and other
products.
Watts - Measurement of electrical ability to do work.
WARRANTY
General Electric Company, (hereinafter called “GE”) warrants to the purchaser that its lamp ballasts, (hereinafter
called lighting products), will be free from defects in material and workmanship for the specified warranty periods
beginning from the date of manufacture.
Electronic Fluorescent Ballasts . . . . . . . . . . . . . . . . . . . . .Up to 60 Months
Standard Electromagnetic, Fluorescent HID,
SLH, Hybrid, Octek™ Fluorescent Ballasts . . . . . . . . . . . .24 Months
Standard Fluorescent Sign Ballasts . . . . . . . . . . . . . . . . .24 Months
MAX-3 or MSB-3 Series Fluorescent Sign Ballasts . . . . . .36 Months
If it appears within the specified warranty period that any GE Lighting Product does not meet the warranty
specified above, GE, at its option, will either repair or replace the Lighting Product at GE's expense. GE extends this
limited warranty to the original or first end-user purchaser only. This warranty is conditional based upon proper stor-
age, installation, use and maintenance.
This warranty is not applicable to, and GE makes no warranty whatsoever with respect to, any
Lighting Product not installed and operated in accordance with the National Electric Code (NEC), the Standards for
Safety of Underwriters Laboratories, Inc. (UL), Standards for the American National Standards Institute (ANSI) or, in
Canada, the Canadian Standards Association (CSA). Nor is this warranty applicable to any Lighting Product which
has not been installed and operated in accordance with GE's specifications and connection diagrams or Lighting
Products which have been subjected to abnormal operating conditions. This includes, but is not limited to, excessive
temperatures as specified in GE's published literature. The conditions for any tests (to be) performed on Lighting
Products which are claimed to have not performed in accordance with the terms of the warranty shall be mutually
agreed upon in writing and GE may be represented at any such tests.
No implied warranty of merchantability or fitness for a particular purpose shall apply
beyond the aforementioned warranty period. The foregoing warranty is exclusive of all other statutory,
written or oral warranties and no other warranties of any kind, statutory or otherwise are given or herein expressed.
Warranty claims are to be made in accordance with GE's published Warranty Service Program which is available
upon request. This warranty sets forth GE's obligations and responsibilities regarding its lighting products and is the
exclusive remedy available to the claimant.
Limitations of Liability, Under no circumstances, whether as a result of breach of contract, breach of war-
ranty, tort, strict liability or otherwise, will GE be liable for consequential, incidental, special or exemplary damages,
including, but not limited to, loss of profits, loss of use or damage to any property or equipment, cost of capital,
cost of substitute product, facilities or services, down time costs or claims of claimants customers. GE's liability for all
claims of any kind or for any loss or damages arising out of, resulting from or concerning any aspect of this warran-
ty or from the Lighting Products or services furnished hereunder, shall not exceed the price of the specific Lighting
Product which gives right to the claim, except in accordance with GE Technical Engineering Service Program.
State Law Right, Some states do not allow the exclusion or limitation of consequential or incidental dam-
ages or the duration of time for an implied warranty. Therefore, the limitations or exclusions of consequential or inci-
dental damage and implied warranties may not apply to certain claimants. This warranty provides the claimant with
specific legal rights and claimants may have other rights that vary from state to state.
Effective: 12/1/99
GE BALLAST WARRANTY
© 2003 General Electric Company Printed in USA. 16122 (4/03)
GE is a registered trademark of General Electric Company. All specification information is subject to change without notification.
FOR THE MOST UP-TO-DATE,
PRODUCT INFORMATION,
VISIT WWW.GELIGHTING.COM
TRANSFORMING THE POWER OF LIGHT
GE BALLAST PRODUCTS CATALOG