658794 Catalog

126428-Catalog 126428-Catalog 126428-Catalog 784572 Batch10 unilog cesco-content

2014-10-17

: Pdf 658794-Catalog 658794-Catalog 784572 Batch10 unilog

Open the PDF directly: View PDF PDF.
Page Count: 48

International Catalog
Metering Equipment
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
2
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
ABOUT
MILBANK
About Milbank
Energy at work since 1927
Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation
sectors. Milbank combines more than 85 years of expertise in electrical engineering design and manufacturing
with a commitment to develop and globally implement sustainable, integrated power solutions. Milbank’s
portfolio includes electric metering systems, PowerGen™ wind and solar solutions, and portable power. A third-
generation, family-owned business, Milbank is headquartered in Kansas City, Mo. For more information, please
visit milbankworks.com.
Milbank meter sockets have set the standard for quality since
1927. With a 99.97% quality performance, thousands of
active products to meet your utility’s requirements and tens of
millions of sockets installed across the globe, our products help
keep energy at work. And with 22 stocking locations across the
U.S., and our OneSERT program to help during emergency
situations, our meter sockets are ready to go, wherever the job
may be.
Milbank’s standby and portable generators give you the peace
of mind of living life uninterrupted during increasingly frequent
power outages caused by severe weather, high demand and
other situations. Our electric vehicle supply equipment, wind
turbines and power management systems give you reliable and
sustainable ways to reduce both your energy costs and your
impact on the environment.
When it comes to commercial and industrial products, Milbank
has it covered! We offer a complete line of junction boxes,
telephone cabinet covers, transformer cabinets, wireways,
pushbutton enclosures, consoles and thermal management
products. We specialize in custom-built enclosures and are
more than happy to design a solution for your specific project.
Our commercial meter pedestals are easy to install, fast, safe
and secure, and completely customizable.
METERING
POWERGEN
COMMERCIAL & INDUSTRIAL
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
TABLE OF
CONTENTS
Table of Contents
See back of catalog for index by catalog number
Single Position Meter Sockets
Economy socket, 4–6 terminals, ring type ........................................................................................................................ 4
100–125 amps, 4 & 5 terminals, ringless & ring type ....................................................................................................... 5
200 amps, 4 & 5 terminals, ringless & ring type ........................................................................................................... 6–7
100–200 amps, 7 terminals, ringless & ring type .............................................................................................................. 8
200 amps, 7 terminals, ringless ......................................................................................................................................... 9
Stainless steel meter sockets .......................................................................................................................................... 10
320 amps, 4 & 5 terminals, lever bypass, ringless .......................................................................................................... 11
Meter Mains
100–200 amps, 4 terminals, ringless ............................................................................................................................... 12
100–200 amps, with load center, 4 terminals, ringless & ring type ................................................................................ 13
320 amps, 4 terminals, lever bypass, ringless ................................................................................................................. 14
Cold sqeuence, 4–7 terminals, ringless ........................................................................................................................... 15
Multi-Position
100 amps, 5 terminals, ringless ....................................................................................................................................... 16
Meter mains, 125 & 200 amps, 4 terminals, ringless ...................................................................................................... 17
Transformer Rated, Test Switches, Transformer Cabinets & Transockets
20 amps, 6–15 terminals, ringless & ring type .......................................................................................................... 18–19
Test switches ............................................................................................................................................................ 20–22
Transformer cabinets ................................................................................................................................................ 23–24
600 amp transockets, 6–14 terminals, ringless ............................................................................................................... 25
Pedestals
100–200 amps, meter main pedestals, 4 terminals, ringless ........................................................................................... 26
100–200 amps, meter main with load center pedestals, 4 terminals, ringless ................................................................ 27
Power Outlets/RV Power
Surface mount power outlets.......................................................................................................................................... 28
Power outlet pedestals ................................................................................................................................................... 29
Miscellaneous
Terminal boxes ......................................................................................................................................................... 30–31
Commercial meter pedestals .................................................................................................................................... 32–33
Generators ...................................................................................................................................................................... 34
Electric vehicle supply equipment .................................................................................................................................. 35
Accessories ............................................................................................................................................................... 36–39
Reference information .............................................................................................................................................. 40–43
3
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
4
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
economy
socket
Economy Socket
4–6 Terminals | 100 Amps | Ring Type
Catalog Number Terminals Hub
Location
Hub
Size Connectors CU/AL Quantity
per Package Knockouts
AP2300-03 4 Top & Bottom (2) 1" #12-#1 12 34", 1"
AP2300-04 4 Top & Bottom (2) 114" #12-#1 12 34", 1"
AP2300-07 4Top 1" #12-#1 12 34", 1"
AP2300-08 4Top 114" #12-#1 12 34", 1"
AP2300-03-5T 5 Top & Bottom (2) 1" #12-#1 12 34", 1"
AP2300-03-5T-AB 5 Top & Bottom (2) 1" #12-#1 12 34", 1"
AP2300-03-6T 6 Top & Bottom (2) 1" #12-#1 12 34", 1"
30-100 Amps | 4, 5 & 6 Terminals | Economy Cast Socket | Ring Type
• Non-UL Listed: These units are not UL tested.
• Fifth Terminal: AP2300-03-5T and AP2300-03-5T-AB include factory-installed fifth terminal
• Sixth Terminal: AP2300-03-6T includes factory-installed sixth terminal.
• Auto-Bypass: -AB suffix indicates installed auto-bypass feature. Consult factory for more details.
• Sealing Rings: These units are supplied with an MR-2 snap action sealing ring as standard.
Notes
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
100–125 AMP
SINGLE
POSITION
SOCKETS
Single Position Sockets
100–125 Amps | Ringless & Ring Type | 600 VAC
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
5
U7487-RL-TG U5934-XL U7490-RL-TG
22
1
33
4
11
2
33
4
Catalog Number Amps Terminals Hub Connectors CU/AL Bypass Dimensions Knockouts
Line Load D" W" H" 1 2 3 4
U7487-RL-TG 125 4 H.O. #6-2/0 #6-2/0 None 3516 8 11122 11211414
U5934-XL 100 4 C.P. #6-2/0 #6-2/0 None 3516 8 11122 11211414
U7487-RL-TG-5T 125 5 H.O. #12-1/0 #12-1/0 None 3516 8 11122 11211414
Catalog Number Amps Terminals Hub Connectors CU/AL Bypass Dimensions Knockouts
Line Load D" W" H" 1 2 3 4
U7490-YL-TG 125 4 114" #6-2/0 #6-2/0 None 3516 8 11122 11211414
U5929-XL 100 4 C.P. #6-2/0 #6-2/0 None 3516 8 11122 11211414
U7490-YL-TG-5T 125 5 114" #12-1/0 #12-1/0 None 3516 8 11122 11211414
4 & 5 Terminals | Single Position | Ringless
4 & 5 Terminals | Single Position | Ring Type
7487 5929
5934
7490
• Aluminum: These units are also available in aluminum. Consult factory for more details.
• Fifth Terminal: For field mounted fifth terminal on the U7487 & U7490 order catalog number 5T8K2 to fit into round
opening at the 9 o’clock position. For factory-installed fifth terminal, add -5T to the catalog number.
• Hubs: For proper hub selection see the hub suffix chart on the accessory page.
• Connectors: Extruded aluminum connectors are tin plated.
• Sealing Rings: The U7490 unit is supplied with an MR-2 snap action sealing ring as standard.
• Horn Bypass: Horn bypass is available—contact factory for details.
• Isolated Neutral: U5929 and U5934 include isolated neutral option, ideal for solar applications.
Notes
SOLAR-FRIENDLY
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
200 AMP
SINGLE
POSITION
SOCKETS
Single Position Sockets
200 Amps | 4 & 5 Terminals | Ringless | 600 VAC
6
• Other Options: These units are also available in aluminum and horn bypass. Consult factory for more details.
• Fifth Terminal: For field mounted fifth terminal, order catalog number K5T to fit into square opening at the 9 o’clock
position. For factory-installed fifth terminal, add suffix -5T to catalog number.
• Triplex Ground (-TG): Factory installed.
• Connectors: Extruded aluminum connectors are tin plated.
Notes
12
3
1 1
7021 7040
Catalog Number Terminals Hub Connectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2 3
U7021-RL-TG 4 H.O. #6-350 #6-350 4188 151221214,1214
U7021-DL-TG 4 2" #6-350 #6-350 4188 151221214,1214
U7040-RL-TG 4 H.O. #6-350 #6-350 41811 145821214,1214
U7021-RL-TG-5T 5 H.O. #6-350 #6-350 4188 151221214,1214
200 Amps | 4 & 5 Terminals | Single Position | Ringless
U7021-RL-TG U7040-RL-TG
11
23
1 1 1
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
200 AMP
SINGLE
POSITION
SOCKETS
Single Position Sockets
200 Amps | 4 & 5 Terminals | Ring Type | 600 VAC
7
1
1
2 3
1 1
1
7018
7017
U7018-XL-TGU7017-RL-TG
Catalog Number Terminals Hub Connectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2 3
U7017-RL-TG 4 H.O. #6-350 #6-350 4188 151221214,1214
U7017-DL-TG 4 2" #6-350 #6-350 4188 151221214,1214
U7018-XL-TG 4 C.P. #6-350 #6-350 4316 1118151221214,1214
U7017-RL-TG-5T 5 H.O. #6-350 #6-350 4188 151221214,1214
200 Amps | 4 & 5 Terminals | Single Position | Ring Type
11
12
3
• Other Options: These units are also available in aluminum and horn bypass. Consult factory for more details.
• Fifth Terminal: For field mounted fifth terminal, order catalog number K5T to fit into square opening at the 9 o’clock
position.
• Triplex Ground (-TG): Factory installed.
• Connectors: Extruded aluminum connectors are tin plated.
• Sealing Rings: Units on this page are supplied with an MR-2 snap action sealing ring as standard.
Notes
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Single Position Sockets
100–200 Amps | 7 Terminals | Ringless | 600 VAC
100–200 AMP
SINGLE
POSITION
SOCKETS
8
Catalog Number Amps Hub Connectors CU/AL Bypass Dimensions Knockouts
Line Load D" W" H" 1 2 3
S1910-YL 100 114" #6-2/0 #6-2/0 None 3516 8 11122 11214
S2417-RL 200 H.O. #6-350 #6-350 None 3516 8 11122 11214
S2417-DL 200 2" #6-350 #6-350 None 3516 8 11122 11214
Catalog Number Amps Hub Connectors CU/AL Bypass Dimensions Knockouts
Line Load D" W" H" 1 2 3 4
S4339-RL 100 H.O. #6-2/0 #6-2/0 None 3516 8 11122 11214
S4275-DL 200 2" #6-350 #6-350 None 4188 151221214,1214
U3328-RXL 200 C.P. #6-350 #6-350 None 47813 19 3 21214,1214
7 Terminals | Single Position | Ringless
7 Terminals | Single Position | Ring Type
Notes
• U3328-RXL: For isolated neutral, order K1047.
• Sealing Rings: Ring type units are supplied with an MR-2 snap action sealing ring as standard.
•Aluminum Option: Products on this page are available in aluminum shell construction. Contact Milbank for details.
S1910-YL
13
2 2
1910
4339
U3328-RXL
12
11
43
13328
S4339-RL
1
12
3
1
4275
S2417-RL
1
2 2 3
4
1
2417
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
200 AMP
SINGLE
POSITION
SOCKETS
Single Position Sockets
200 Amps | 7 Terminals | Ringless | 600 VAC
9
1
34
1 1 1
2
These units have a large hub opening with reducer plate to small hub opening.
• Bypass: 1 Medium duty, no bypass. 2 Medium duty lever bypass, non jaw-clamping. 3 Lever supplies clamping action on
meter spades and also operates bypass device.
•Aluminum Option: Products on this page are available in aluminum.
•4 & 5 Terminal Option: These units are also available in 4 & 5 terminals.
Notes
Catalog Number Hub Connectors CU/AL Bypass Dimensions Knockouts
Line Load D" W" H" 1 2 3 4
U7420-RL H.O. #6-350 #6-350 None 1 47810 18123 2123414,12
U7421-RL H.O. #6-350 #6-350 Lever 2 47810 18123 2123414,12
U7422-RXLC.P. #6-350 #6-350 None 1 47813 19 3 21214,1214
U7423-RXLC.P. #6-350 #6-350 Lever 2 47813 19 3 21214,1214
U9700-RRLH.O. #6-350 #6-350 Lever 3 47810 18123 2123414,12
U9701-RXLC.P. #6-350 #6-350 Lever 3 47813 19 3 21214,1214
200 Amps | 7 Terminals | Single Position | Ringless
U7421-RL U9700-RRL
1
1
2
3
3
47420
7421
9700
7422
7423
9701
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
10
STAINLESS
STEEL
PRODUCTS
Stainless Steel Products
Build to endure extreme environments
USS4701-O UCSS3433-O
Catalog
Number Terminals Hub Connectors CU/AL Bypass Dimensions
Line Load D" W" H"
USS3914-O 4 Blank #6-350 #6-350 None 47813 19
USS4801-O 4 Blank #6-350 #6-350 Lever 47813 19
USS4801-O-5T9 5 Blank #6-350 #6-350 Lever 47813 19
USS4701-O 7 Blank #6-350 #6-350 Lever 47813 19
Catalog Number Terminals Hub Connectors CU Bypass Dimensions
D" W" H"
UCSS3436-O 6 Blank #14 - 2 Test Switch* 51812 20
UCSS3438-O 8 Blank #14 - 2 Test Switch* 51812 20
UCSS3433-O 13 Blank #14 - 2 Test Switch* 51812 20
200 Amps | Single Position | Stainless Steel | Ringless
Transformer Rated | With Provisions for Test Switch | Stainless Steel | Ring Type
• Conduit Opening Applications: All conduit openings have dimples provided to center location. Top conduit
opening must have water-tight hub installed.
• *Test Switch: Test switch provisions. Test switch and wiring not included.
• Contact Milbank for other units available in stainless steel.
Notes
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Single Position Lever Bypass
320 Amp | 4 & 5 Terminal | Ringless | 600 VAC
320 AMP
SINGLE
POSITION
LEVER BYPASS
11
1 1
1
23
11
1 1
111
23
U4363-R U1797-O-K2L-K3L
4363 4505 1797
Catalog Number Terminals Hub Connectors CU/AL Bypass Dimensions Knockouts
Line Load D" W" H" 1 2 3
U4363-R* 4 H.O. 38" x 16 Stud 38” x 16 Stud Lever 47813 2814314,1214
U1797-O-K2L-K3L 4 Blank
(1) #4-600 or
(2) 1/0-250
Twin #6-350 Lever 47813 2814314,1214
U4505-X 5 C.P. 38" x 16 Stud 38” x 16 Stud Lever 47815 2814314,1214
320 Amps | 4 & 5 Terminals | Single Position | Ringless
• *UL Listing:
This product is UL listed for parallel 250 conductors only. Use K1450 with (2) 250 conductors.
• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.
• Connectors: U1797 includes lugs. U4363 and U4505 are supplied with 38"-16 hex head nuts with Belleville washers. For
connector lug kits, order as extra from chart on accessories page. Separate lug kits are required for line and load.
•Bypass: Lever supplies clamping action on meter spades and also operates bypass device.
•Fifth Terminal: For field-installed fifth terminal for U4363 and U1797, order K3865.
Notes
11
11 1
2
3
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Meter Mains
100–200 Amps | 4 Terminals | Ringless | 120/240 VAC
100–200 AMP
METER MAINS
U5842-RL-100 U5844-PXL-200
1 1
12
3
1 2
3
5
3
3
4
4
4
4
22 2
5842
5852
5844 5854
Catalog Number Service Hub Connectors CU/AL Bypass Dimensions Knockouts
Line Load D" W" H" 1 2 3 4 5
U5842-RL OH H.O. #6-350 None 4188 30 21214,1214— —
U5842-RL-100 OH H.O. #6-350 CB - 100A None 4188 30 21214,1214— —
U5842-PXL-200 OH C.P. #6-350 CB - 200A None 4188 30 21214,1214— —
U5844-PXL-200 OH/UG C.P. #6-350 CB - 200A None 41214 30 3 212112,3414,12
Catalog Number Service Hub Connectors CU/AL Bypass Dimensions Knockouts
Line Load D" W" H" 1 2 3 4 5 6
U5852-RL OH H.O. #6-350 None 4188 30 21214,1214———
U5852-RL-100 OH H.O. #6-350 CB - 100A None 4188 30 21214,1214———
U5852-RL-200 OH H.O. #6-350 CB - 200A None 41814 30 21214,1214———
U5854-RL-200 OH/UG H.O. #6-350 CB - 200A None 412141430 3 2122 1 12,3414,12
4 Terminals | Meter Mains | Ringless
4 Terminals | Meter Mains | Ring Type
Notes
Breaker not included
• AIC Rating: All models are rated 22K AIC when using Siemens QPH (100A) or QNH (200A) breakers.
• Hub: -PXL versions supplied with one (1) closing plate packed inside. Order other hubs separately.
• Fifth Terminal: For field installable fifth terminal kit, order K5T.
12
3 3 3
4
5
5
5
64
12
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
100–200 AMP
METER MAIN
W/ LOAD CENTER
Meter Main with Load Center
100–200 Amps | 4 Terminals | 120/240 VAC
1 2
33
4 5
5
6
63
1 2
3 3 3
4 56
5
4
5
UAP5024-XL
U5168-XTL-200
4 Terminals | Meter Mains | Ringless
4 Terminals | Meter Mains | Ring Type
• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.
• Fifth Terminal: For field installed fifth terminal, order K5T.
• Interlock Kit: For generator auxiliary circuit breaker interlock, order K5815 for large QN with small frame Q; order K5820
for large frame QN with large frame QN; order K5830 for small frame Q to small frame Q. See accessories page for details.
• UAP5024-XL: This unit is painted aluminum. Breaker section has provision for six double pole “plug-in” type circuit
breakers. All circuit breakers will be parallel. To comply with NEC wire bending space requirements, the maximum breaker
amperage is 200 amps restricted to 3/0 copper conductor.
Notes
5024
5168
5169
Catalog Number Amps Service Circuits Hub Connectors
CU/AL - Line
Dimensions Knockouts
D" W" H" 1 2 3 4 5 6
U5168-XTL-100 100 OH/UG 10 C.P. #6-350 412141830 3 2122 1 12,3414,12
U5168-XTL-200 200 OH/UG 8 C.P. #6-350 412141830 3 2122 1 12,3414,12
UAP5024-XL 200 OH/UG 12 C.P. #6-350 412141824 3 2122 1 12,3414,12
Catalog Number Amps Service Circuits Hub Connectors
CU/AL - Line
Dimensions Knockouts
D" W" H" 1 2 3 4 5 6
U5169-XTL-100 100 OH/UG 10 C.P. #6-350 412141830 3 2122 1 12,3414,12
U5169-XTL-200 200 OH/UG 8 C.P. #6-350 412141830 3 2122 1 12,3414,12
Amps Cutler Hammer Siemens General Electric Square D
150-200 BR, BRH, HQP, QPHW, QPGF, QPHGF QP, QPH THQL, THHQL, THQL-GF, THHQL-GF Homeline
≤ 125 QP / BR QP, QPH THQ Homeline
Plug-In Breaker Compatibility Chart
13
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Lever Bypass Meter Mains
320 Amps | 4 Terminals | Ringless | 120/240 VAC
320 AMP
LEVER BYPASS
METER MAIN
U5890-X-2/200 U5894-X-2/200
1
2
2
3
2
22
2
5
3
3 3
4
4 4
1
2
2
5890
5893
5891
5892
5894
5895
Catalog Number Service Hub Side
Wireway
Connectors
CU/AL - Line
Branch
Circuits
Dimensions Knockouts
D" W" H" 1 2 3 4 5
U5890-X-2/200 OH/UG C.P. No 38" x 16 Studs N/A 6 241235 4 21214— —
U5891-X-2/200 OH/UG C.P. No 38" x 16 Studs 12 6 291235 4 212112,3414
U5892-X-2/200 OH/UG C.P. No 38" x 16 Studs 24 6 291235 4 212112,3414
U5893-X-2/200 OH/UG C.P. Yes 38" x 16 Studs N/A 6 241235 4 21214— —
U5894-X-2/200 OH/UG C.P. Yes 38" x 16 Studs 12 6 291235 4 212112,3414
U5895-X-2/200 OH/UG C.P. Yes 38" x 16 Studs 24 6 291235 4 212112,3414
320 Amps | 4 Terminals | Meter Mains | Lever Bypass | Ringless
• Hubs: For proper hub selection refer to the hub suffix chart on the accessory page.
• Breakers: All units come with two 200A main breakers.
• Side Bussed Units: U5893, U5894 and U5895.
• -MLK: Main Lug feed-through kit K3701 factory installed on U5891 and U5894.
• Fifth Terminal: For field mounted fifth terminal order catalog number K3865.
•Connectors: Socket is supplied with 3/8” - 16 hex head nuts with Belleville washers. For connector lug kits, order as extra
from chart on accessories page. Separate lug kits are required for line side only.
Notes
Amps Cutler Hammer Siemens General Electric Square D
150-200 BR, BRH, HQP, QPHW, QPGF, QPHGF QP, QPH THQL, THHQL, THQL-GF, THHQL-GF Homeline
≤ 125 QP / BR QP, QPH THQ Homeline
Plug-In Breaker Compatibility Chart
14
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
COLD
SEQUENCE
METER MAINS
Cold Sequence Meter Mains
4, 5 & 7 Terminals | Ringless
200 Amp Circuit Breaker Disconnect Ahead Of Meter Socket
400 Amp (320 Amp Continuous) Circuit Breaker Disconnect Ahead Of Meter Socket
Catalog Number Terminals Service Hub Connectors CU/AL Bypass Dimensions Knockouts
Line & Load D" W" H" 1 2 3 4
U5764-X-200-CB 4 OH/UG C.P. #6-350 Lever 42732 13 43 4 21214
U5765-X-200-CB 5 OH/UG C.P. #6-350 Lever 42732 13 43 4 212112 , 34
U5784-O-200-CB 5 UG Blank #6-350 Lever 42732 26 28 4 21214
U5767-X-200-CB 7 OH/UG C.P. #6-350 Lever 42732 13 43 4 212112 , 34
U5787-O-200-CB 7 UG Blank #6-350 Lever 6 26 28 4 212112 , 34
Catalog Number Terminals Service Hub Connectors CU/AL Bypass Dimensions Knockouts
Line Load D" W" H" 1 2 3 4
U5797-O-400-CB 5 UG Blank 3/0-500 3/0-500 Lever 6 26
36
4 212112 , 34
U5796-X-400-CB 7 OH/UG C.P. 3/0-500 3/0-500 Lever 6 13 56 4 21214
U5799-O-400-CB 7 UG Blank 3/0-500 3/0-500 Lever 6 26
36
4 212112 , 34
U5767-X-200-CB U5787-O-200-CB
1
1 1 1
23
1
5764
5765
5767
1
2
3 344
2 2 2
1 1
1 1
5784
5787
1
1
2 2
34
1
5796
5797
5799
1
1
2 2 2 2
343
1
1 1
Notes
• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.
15
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Multi-Position Sockets
100 Amps | 4 Terminals | 300 VAC
100 AMP
MULTI-
POSITION
1
333333
12 2 2 2
2 2 2 2 2
2
22222211
33
2222
22
1
22222
2 22222
3 3
1
13 3
2 2 2
2 2 2 2
U8212-RL
Catalog
Number Positions Hub Connectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2 3
U8212-RL 2 H.O. #6-350 #6-2/0 41220516 16 212214,12
U8213-RL 3 H.O. #6-350 #6-2/0 412281216 212214,12
U8214-RL 4 H.O. #6-350 #6-2/0 412401116 16 212214,12
U8215-RL 5 H.O. #6-350 #6-2/0 412487816 212214,12
U8216-XL 6 C.P. #6-350 #6-2/0 41257116 16 212214,12
100 Amps per Position | 4 Terminal | Multi-Position | Ringless
Notes
• Hub: For proper hub selection refer to the hub suffix chart on the accessory page. A hub opening is supplied at each end
and the extra opening is closed with a closing plate as standard.
• Fifth Terminal Kit: For field mounted fifth terminal, order 5T8K2 (6 o’clock position).
• Connectors: Extruded aluminum connectors are tin plated.
• 200 Amp Units: 200 amp per position units available—consult factory.
1 2 2
2 22
3 3 8212
8213
8215 8216
8214
16
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
125–200 AMP
MULTI-POSITION
METER MAINS
Multi-Position Meter Mains
125 & 200 Amp | 4 Terminals | Ringless | 120/240 VAC
Catalog
Number Amps Positions Service Hub Connectors CU/AL Dimensions Weight
(lbs.)
Line D" W" H"
U5902-X 125 2 OH/UG C.P. 38” x 16 Stud 518261230 58
U5903-X 125 3 OH/UG C.P. 38” x 16 Stud 518345930 88
U5904-X 125 4 OH/UG C.P. 38” x 16 Stud 518424530 107
U5905-X 125 5 OH/UG C.P. 38” x 16 Stud 51851120 30 128
U5906-X 125 6 OH/UG C.P. 38” x 16 Stud 51859310 30 146
Catalog
Number Amps Positions Service Hub Connectors CU/AL Dimensions Weight
(lbs.)
Line D" W" H"
U5882-X 200 2 OH/UG C.P. 38” x 16 Stud 518261230 58
U5883-X 200 3 OH/UG C.P. 38” x 16 Stud 518345930 88
U5884-X 200 4 OH/UG C.P. 38” x 16 Stud 518424530 107
U5885-X 200 5 OH/UG C.P. 38” x 16 Stud 51851120 30 128
U5886-X 200 6 OH/UG C.P. 38” x 16 Stud 51859310 30 146
125 Amps per Position | 4 Terminal | Multi-Position Meter Mains | Ringless
200 Amp / Position | 4 Terminal | Multi Position Meter Mains | Ringless
Notes
• Optional: Factory installed breakers are available—consult factory.
• AIC Rating: All models are rated 22K AIC with Siemens breakers.
• Hub: Units supplied with one (1) closing plate. Order hubs separately, see accesory page.
• Fifth Terminal: For field installed fifth terminal, order K5T.
•Connectors: Socket is supplied with 3/8” - 16 hex head nuts with Belleville washers. For connector lug kits, order as extra
from chart on accessories page. Separate lug kits are required for line side only.
U5882-X U5884-X
17
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
20 AMP
TRANSFORMER
RATED
Transformer Rated
20 Amps | 6–15 Terminals | 600 VAC
11
2
3
2 2
20 Amps | Ringless | Plunger Bypass | Overhead/Underground Service
20 Amps | Ring Type | Overhead/Underground Service
Catalog
Number Terminals Hub Meter Form Connectors
CU Bypass Dimensions Knockouts
D" W" H" 1 2 3 4
UC1299-RL 6 H.O.
4S
#14 - #10 Plunger 3516 8 14 2 11211414
UC7235-RL 8 H.O.
5S
#14 - #10 Plunger 3516 8 14 2 11211414
UC7237-RL 13 H.O.
6, 8, 9S & (ALT) 10S
#14 - #10 Plunger 3516 8 14 2 11211414
Catalog
Number Terminals Hub Meter Form Connectors
CU Bypass Dimensions Knockouts
D" W" H" 1 2 3
UC1300-XL 6 H.O.
4S
#14 - #4 Max Plunger 3516 8 14 11211414
UC7544-XL 8 H.O.
3S
#14 - #4 Max Plunger 3516 8 14 11211414
UC7545-XL 13 H.O.
6, 8, 9S & (ALT) 10S
#14 - #4 Max Plunger 3516 8 14 11211414
UC5732-XL 15 H.O.
Special
#14 - #4 Max None 3516 8 14 11211414
Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.
• Bypass: Plunger type bypass automatically closes when meter is removed.
• Connectors: Units are supplied with mechanical type connectors (#4 max).
2
1
4
33
2
1299
7235
7237 1300
7544
7545
5732
UC7237-RL
18
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
20 AMP
TRANSFORMER
RATED
Transformer Rated
20 Amps | 6–13 Terminals | Test Switch Provision
11
12
11 7444
7445
7446
7448
7449
7478
7532
1 Piece Cover | Ringless | Overhead/Underground | with test switch provision*
2 Piece Cover | Ringless | Overhead/Underground | with test switch provision*
Catalog
Number Terminals Hub Meter Form Connectors
CU Bypass Dimensions Knockouts
D" W" H" 1 2
UC7478-RL 6 H.O. 4S #14 - #4 Max None 41812 20 11414, 12
UC7444-RL 8 H.O. 5S #14 - #4 Max None 41812 20 11414, 12
UC7445-RL 13 H.O.
6, 8, 9 & (ALT) 10S
#14 - #4 Max None 41812 20 11414, 12
UC5087-RL 13 H.O.
6, 8, 9 & (ALT) 10S
#14 - #4 Max Plunger 41812 20 11414, 12
Catalog
Number Terminals Hub Meter Form Connectors
CU Bypass Dimensions Knockouts
D" W" H" 1 2
UC7532-RL 6 H.O. 4S #14 - #4 Max None 41812 20 11414, 12
UC7448-RL 8 H.O. 5S #14 - #4 Max None 41812 20 11414, 12
UC7449-RL 13 H.O.
6, 8, 9 & (ALT) 10S
#14 - #4 Max None 41812 20 11414, 12
UC7449-XL UC7532-RL
(shown prewired with
Milbank test switch)
UC7478-YL
Notes
• Hubs: For proper hub selection see the hub suffix chart on the accessory page.
• Prewiring: If standard factory pre-wiring is required, refer to wiring diagrams in the general engineering section of this
catalog. Determine appropriate diagram and send copy with order. If custom factory prewiring is required, specify on
order. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be
sure to provide a copy of your wiring diagram. Catalog number will change to match wiring.
• Connectors: Units are supplied with mechanical type connectors (#4 max).
• *Test Switch Cover: Units on this page are not designed for use with test switch covers. Units are available in 512" deep
shell for test switch cover—contact factory for details. It is also possible to remove the test switch bridge and mount a test
switch to the back of the enclosure.
• Ring Type Option: 2-piece cover units are available in ring type—contact factory for details.
19
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Test Switches
4, 7 & 10 Pole
TEST
SWITCHES
Factory Installed: For cover installed add the suffix -WC or -WCFL to the catalog number of desired test switch.
Field Installed: For field installed cover order kit number K3388 or K3388-BLK-FL.
The Milbank test switch is designed to meet the critical requirements of the electric utility industry. Not only do
they meet EEI, ANSI C12.9, and UL standards but they combine several special features giving the Milbank test
switch increased safety, durability and reliability. One such feature is our unique switch blade contact points
which cut through residue that builds up after years of service. Another distinction is our polarity barrier which is
designed to be flexible as well as offer exceptional insulating qualities. Our test switches are constructed from the
latest materials available using modern fabricating and assembly methods.
Switch Blades
Two dimples coined into one
side of the switch blade ensure
positive contact in corrosive, sooty
environments—even after years of
inactivity.
Test Switch Covers
Standard test switch covers are made
from impact resistant clear thermal
plastic which has excellent tracking
and moisture resistant properties. If
covers are required, add suffix -WC
(with cover) to the catalog number
or order separately catalog number
K3388. Black flush mount covers are
also available. Order catalog number
K3388-BLK-FL. 10 pole base only.
Standard Cover
Test Switch Base
The base is molded from a high
strength, fiberglass reinforced,
thermoset polyester. This material is
track resistant, flame retardant and has
low water absorption qualities. Bases
are available in 7 pole and 10 pole
sizes.
Switch Jaws
The switch blade jaw clips are
constructed from spring grade copper
alloy. The material and design ensure
excellent contact which prevents
overheating.
Socket shells must be 518" deep
-OR-
must not have test switch bridge
mounted on back
in order to support a cover.
Polarity Barrier
For maximum protection potential
circuits are supplied with permanently
mounted barriers made from high
tensile strength polycarbonate.
Current Carrying Parts
Highly conductive copper and copper
alloy materials are used on all current
carrying parts. This ensures conductivity
and deters corrosion. Spring grades
are used where appropriate. Plating is
available if required. Contact general
offices to special order.
Flush Mount Cover (Black)
20
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
TEST
SWITCHES
Test Switches
4, 7 & 10 Pole
7 1/2"
3 1/2"
3 1/2"
9 1/2"
Key
P Potential Switch
C+ Line side current switch with
short circuit assembly
CLoad side current switch
with test jack assembly
N Neutral bar (no switch)
Pn Neutral Potentail Switch
X Unused Position on base
Insulating barrier, isolates
both sides of switch
Catalog
Number 7-Pole on a 10-Pole Base
TS07-0049 P X P X Pn X C+ C C C+
TS07-0106 X P C+ C P C+ C Pn X X
Catalog
Number 10-Pole
TS10-0109 P P P Pn C+ C C+ C C+ C
TS10-0110 P C+ C P C+ C P C+ C Pn
TS10-0111 P P P Pn C C+ C C+ C C+
TS10-0112 C+ C C+ C C+ C P P P Pn
TS10-0016 P P P Pn C C+ C C+ C C+
Catalog
Number 7-Pole
TS07-0105 P P Pn C+ C C+ C
Catalog
Number 4-Pole
TS04-0101 X P Pn X C+ C X
TS04-0104 X C+ C X P Pn X
Custom Pole Arrangements:
The key may be used to diagram
your own pole arrangement. Be
sure to specify base size and
whether all C+ line side, current
switch / shunt circuit assemblies
are to be bussed together. The
catalog numbers shown above
are connected in line-load pairs;
therefore, if bussed is required,
different catalog numbers will
apply.
21
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
TEST SWITCH
WORKSHEET
Test Switch Worksheet
Key
P Potential Switch
C+ Line side current switch with
short circuit assembly
CLoad side current switch
with test jack assembly
N Neutral bar (no switch)
Pn Neutral Potential Switch
X Unused Position on base
Insulating barrier - one side
Insulating barrier - two sides
4
7
10
Other ____
Yes | Clear ___ Black ___
No
7-Pole
10-Pole
Number of Poles Test Switch Cover (only available for 10-pole bases)
Base Size
q q
q q
q
q
q
q
Engineering Information: _________________________________________________________________________
_________________________________________________________________________________________________
_________________________________________________________________________________________________
Customer Name: ________________________________________________________________
Address: _______________________________________________________________________
________________________________________________________________________________
Phone / Fax #: _________________________________________________________________
Custom Pole Arrangements: The key may be used to diagram your own
pole arrangement. Be sure to specify base size and whether all C+ line side,
current switch / shunt circuit assemblies are to be bussed together. The
catalog numbers shown above are connected in line-load pairs; therefore, if
bussed is required, different catalog numbers will apply.
TEST SWITCH BASE
The base is molded from a high strength,
fiberglass reinforced, thermoset polyester.
This material is track-resistant, flame-retardant
and has low water absorption qualities. Bases
are available in two standard sizes following
NEMA mounting classifications.
Handle Color Key
BK Black P Purple Y Yellow GN Green
R Red BL Blue W White BKS Black Stripe
BR Brown GR Grey O Orange WS White Stripe
12345678910
Pole Position Chart
Feature 12345678910
45° Angle Stops
Ganged Handles (C)
Bussing
Colored Handles
Special Features
22
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
CURRENT
TRANSFORMER
CABINET
Current Transformer Cabinet
Panel Enclosure | Type 3R
For use as a current transformer cabinet or panel enclosure.
•Foroutdoorusetoprovideprotectionagainstrain,sleet
and snow, or indoor use to protect against dripping water.
Construction
Enclosure and cover manufactured from 16 or 14 gauge
G90U galvanized steel.
The doors are overlapping with no center post.
Continuous door hinge with stainless steel hinge pins.
Three point pad-lockable handle.
Panel mounting studs provided for optional back panels.
Drip shield top and seam-free sides, front and back.
Finish
ANSI 61 gray polyester powder coating over phosphatized
G90U galvanized steel.
Application
Current Transformer Cabinets | Panel Enclosure
Catalog
Number
UPC #
(7-84572) Weight Dimensions Steel Panel Catalog # Wood Panel Catalog #
W" H" D"
363010-CT3R 18823 99 36 30 10 A-36P30 A-36P30W
363016-CT3R 16181 121.5 36 30 16 A-36P30 A-36P30W
363610-CT3R 17368 113 36 36 10 A-36P36 A-36P36W
363612-CT3R 16185 118 36 36 12 A-36P36 A-36P36W
363616-CT3R 18819 139 36 36 16 A-36P36 A-36P36W
483616-CT3R 25707 163 48 36 16 A-48P36 A-48P36W
484812-CT3R 16184 210 48 48 12 A-48P48 A-48P48W
606013-CT3R 18252 274 60 60 13 A-60P60 A-60P60W
PT Cabinets
Catalog Number Dimensions Knockout
D" W" H"
PT48L 8 8 2712212" - right side
PT48AL 8 12 36 212" - right side
PT48R 8 8 2712212" - left side
PT48AR 8 12 36 212" - left side
Notes
• *PT48: PT48L and PT48AL has mounting emboss on the right side to be mounted on left side of CT cabinet. PT48R and
PT48AR have mounting emboss on left side to be mounted on right side of CT cabinet.
Wall or Pole Mount: For wall or pole mount CT rack order S7860. This unit accomodates 3 donut style CTs. The
removable cover makes wiring much easier.
PT48AR* S7860
23
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Transformer Cabinets
800 Amps
TRANSFORMER
CABINETS
800 Amps | Transformer Cabinets
Catalog Number C.T. Racks Dimensions Front Cover Cover Type
D" W" H"
CT244811-SC A 11 24 48 1 Piece Screw
CT304811-SC A, B, G, H 11 30 48 1 Piece Screw
CT364811-SC A, B, G, H 11 36 48 1 Piece Screw
CT244811-HC A 11 24 48 1 Piece Hinge
CT304811-HC A, B, G, H 11 30 48 1 Piece Hinge
CT364811-HC A, B, G, H 11 36 48 1 Piece Hinge
Notes
• Enclosure: These units are rated Type 3R, powder coated and constructed of galvanized steel.
• Mounting: 14 - 20 welded studs for use with CT mounting rack.
CT364811-HC CT Cabinet
and K4722 CT Rack
CT Cabinet Mounting Racks
Code Catalog
Number AIC Rating Amps Volts Type of Service Termination Type
A K4797 50K 800 600 1Ø3W or 3Ø3W 12 - 13 studs on 134" centers
B K4798 50K 800 600 3Ø4W 12 - 13 studs on 134" centers
G K4729 50K 800 600 1Ø3W or 3Ø3W 6 lugs: (3) #4-600 or (6) #1-250
H K4722 50K 800 600 3Ø4W 8 lugs: (3) #4-600 or (6) #1-250
K4729 (with lugs) K4722 (with lugs)
K4797 (studs) K4798 (studs)
24
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
600 AMP
TRANSOCKETS
Transockets
600 Amps | 6–14 Terminals | Donut or Bar Type CTs
S2690-XT S2690-XT
11
3
11222
1
1
11
22
333
2
22
1890
1891
3912
2674
2690
3831
600 Amps | 600 Volts | With PTs and Donut Type CTs | Ringless
600 Amps | 600 Volts | Bar Type CTs Only | Ringless
Catalog
Number Terminals Hub Meter
Form
PTs Quantity
& Ratio
CTs Quantity
& Ratio
Dimensions Knockouts
D" W" H" 1 2 3
S1891-XT 8 (2) C.P. 5S (2) 4:1 (2) 200/5 91218 24 21211116
S3912-XT 13 (2) C.P. 6S (2) 2.5:1 (3) 200/5 91218 24 21211116
S1890-XT 14 (2) C.P. 6S (2) 2.5:1 (3) 200/5 91218 24 21211116
Catalog
Number Terminals Hub Meter
Form
CTs Quantity
& Ratio
Dimensions Knockouts
D" W" H" 1 2 3
S3831-XT 6 (2) C.P. 4S (2) 200/5 111418 30 4 3121
S2690-XT 8 (2) C.P. 5S (2) 200/5 111418 30 4 3121
S2674-XT 13 (2) C.P. 8S (3) 200/5 111418 30 4 3121
Notes
• Hubs: Units are supplied with two closing plates as standard. To order hubs as extra refer to the hub suffix chart on the
accessory page.
• Prewiring: Units supplied prewired with test switch and transformers in place. Contact factory if wiring diagram is desired.
• Pricing: Contact general office for pricing information.
• Other units available - contact factory for details.
S1890-XT
25
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
100–200 AMP
METER MAIN
PEDESTAL
Meter Pedestal
100–200 Amps | 4 Terminals | Ringless | 120/240 VAC
Grade Line
1
1
NU8980-O-KK
8980
4 Terminals | Ringless | Underground Service
Catalog Number Amps Hub Connectors CU/AL Bypass Dimensions Knockouts
Line Load D" W" H" 1 2
U8436-O 200 Blank 4/0 (line)
2/0 (neutral) #6-350 Horn 4189 62 2 14,12
NU8980-O 200 Blank #6-350 CB1None 6 9 79 212
NU8980-O-SF100 100 Blank #6-350 CB None 6 9 79 212
NU8980-O-2002200 Blank #6-350 CB None 6 9 79 212
1 Field Installed Circuit Breaker Required. 2 Milbank main breaker.
• Hanging Hook: U8436 is supplied with keyhole hanger for easy mounting to building.
• Extension Unit: For U8436, order extension unit K5800 for 15” burial applications and two K5800 units for 30” burial
applications.
• Series Wired Main: For series wired main order wire kit K4714 and UQFPH-M type circuit breaker.
• Branch Circuit Breakers: Branch interior accepts most manufacturers’ small frame plug-in type circuit breakers (Milbank,
GE, Siemens, Cutler-Hammer, Murray).
• SF: SF in catalog number has small frame plug-in type circuit breaker installed on middle stabs of 4-circuit interior. Only
two single pole spaces available.
• Fifth Terminal: For field installed fifth terminal, order catalog number K5T.
• Listing: Listed for free standing or wall mount.
Notes
U8436-O
GRADE LINE
18.00
1
1 1
1
1
2 2
2 2
2
2
8436
26
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
100–200 AMP
METER MAIN
W/ LOAD CENTER
PEDESTAL
Meter Main w/ Load Center Pedestal
100–200 Amps | 4 Terminals | Ringless
U5136-O-200S
24”
27.5”
50”
80”
Grade Level
1
1
2 2
3 3
1
1
9.875” 4.13”
16.07”
5136
5137
100-200 Amps | 4 Terminals | Meter Main Pedestal | Ringless
Catalog Number Service Meter
Positions Bypass Connectors CU/AL Knockouts
Line Load 1 2 3
U5136-O-100S UG Single Horn #6-350 CB 2 12,3414
U5136-O-200S UG Single Horn #6-350 CB 2 12,3414
U5137-O-200S UG Double Horn #6-350 CB 2 12,3414
Notes
• Parallel to Series Conversion: For field converting from parallel wired to series wired order K5194.
• Fifth Terminal: For field installed fifth terminal, order K5T.
• Stabilizer Foot: For field installed stabilizer foot, order K5415.
• Application: Designed for free standing direct burial.
• Receptacles: Consult factory for installed receptacle assemblies.
• Main Breaker: Milbank UQFP-M-(AMP).
• Ring Type Units: Ring type units available—contact Milbank for details.
27
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Surface Mount Power Outlet
Millennium Series | Metered & Unmetered
SURFACE
MOUNT
POWER
OUTLETS
125 Amps | Surface Mount Power Outlets
Receptacle Configurations
Circuit Breaker Configurations
Catalog Number Metered/
Unmetered
Receptacle
Configuration
Circuit Breaker
Configuration
Loop Feed
Line
Dimensions Knockouts
D" W" H" 1 2 3
U5000-XL Unmetered (2) 1/0-#12 51291819142 112114
U5000-XL-41 Unmetered A X (2) 1/0-#12 51291819142 112114
U5000-XL-55 Unmetered B Y (2) 1/0-#12 51291819142 112114
U5000-XL-75 Unmetered C Z (2) 1/0-#12 51291819142 112114
U5100-XL Metered #6-250 51291825 2 112114
U5100-XL-41 Metered A X #6-250 51291825 2 112114
U5100-XL-55 Metered B Y #6-250 51291825 2 112114
U5100-XL-75 Metered C Z #6-250 51291825 2 112114
122
33
5000
A B C
(1) TT30R, (1) 5-20R GFI
(1) 14-50R, (1) 5-20R GFI
(1) 14-50R, (1) TT30R,
(1) 5-20R GFI
X Y Z
(1) 30A, 1P, 120V
(1) 20A, 1P, 120V
(1) 50A, 2P, 120/240V
(1) 20A, 1P, 120V
(1) 50A, 2P, 120/240V
(1) 30A, 1P, 120V
(1) 20A, 1P, 120V
1
33
22
5100
U5000-XL-75 U5100-XL-75
Notes
• Other Configurations: Additional
configurations are available—contact
Milbank for details.
• Metered Units: Metered units are
ring type.
28
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
POWER
OUTLET
PEDESTALS
Power Outlet Pedestals
Millennium Series | Metered & Unmetered
125 Amps | Power Outlet Pedestals
Receptacle Configurations
Circuit Breaker Configurations
Catalog Number Double Head
Catalog Number
Receptacle
Configuration
Circuit Breaker
Configuration
Dimensions Knockouts
D" W" H" 1
U5200-XL U5220-XL — 5916 9186412114
U5200-XL-41 U5220-XL-41 A X 5916 9186412114
U5200-XL-55 U5220-XL-55 B Y 5916 9186412114
U5200-XL-75 U5220-XL-75 C Z 5916 9186412114
U5300-O U5320-O — 5916 9187014114
U5300-O-41 U5320-O-41 A X 5916 9187014114
U5300-O-55 U5320-O-55 B Y 5916 9187014114
U5300-O-75 U5320-O-75 C Z 5916 9187014114
A B C
(1) TT30R,
(1) 5-20R GFI
(1) 14-50R,
(1) 5-20R GFI
(1) 14-50R, (1) TT30R,
(1) 5-20R GFI
X Y Z
(1) 30A, 1P, 120V
(1) 20A, 1P, 120V
(1) 50A, 2P, 120/240V
(1) 20A, 1P, 120V
(1) 50A, 2P, 120/240V
(1) 30A, 1P, 120V
(1) 20A, 1P, 120V
12 2
5200
5220
U5200-XL-75 U5300-O-75
12 2
5300
5320
Notes
• Other Configurations: Additional configurations
are available—contact Milbank for details.
• Metered Units: Metered units are ring type.
29
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
TERMINAL
BOX
Terminal Box
100–400 Amps | 120/240 Volts
Shown with
optional 3Ø
Lug Kit
1 1
1
1 1 1
34
1
2
3
3 3
4
U4540-XL S9617-O
4540
4542
4544
4546
4548
4549
Terminal Boxes | 1Ø and 3Ø | 120/240 Volts
Secondary Service Pedestal for Underground Use
Catalog
Number Amps Phase Volts Hub Connectors
CU7AL
1Ø to
3Ø Kit
Dimensions Knockouts
D" W" H" 1 2 3 4
U4544-XL 100 1 120/240 C.P. (6) #12-1/0 K4543 41891316 18 2 1 14,12
U4546-XL 100 3 600 C.P. (6) #12-1/0 N/A 41891316 18 2 1 14,12
U4540-XL 200 1 120/240 C.P. (6) #6-350 K4539 418141316 23 21221211414,12
U4542-XL 200 3 600 C.P. (6) #6-350 N/A 418141316 23 21221211414,12
U4548-RXL 400 1 120/240 C.P. (3) #6-350 or
(2) #4-600 K4547 5 151227 3 3 14,1214
U4549-RXL 400 3 600 C.P. (3) #6-350 or
(2) #4-600 N/A 5 151227 3 3 14,1214
Catalog Number Pedestal Supplied With Dimensions
D" W" H"
S9617-O (3) 6 hole 350 MCM connector bars 101132 1038451116
Notes
• Hub: Standard hub opening on top with closing plate attached.
• Features: UL-listed pad lockable Type 3R enclosure.
• 3Ø 120/240V Application: Field installable 3Ø lug kit converts 1Ø unit to 3Ø unit.
Notes
• Features: Unit supplied with 3/8"-16 penta head bolt and pad-lockable latch.
• Stake: Catalog number S9110 must be added to catalog number in order to ensure shipment of 72" stake for free
standing installation (i.e. S9617-O-S9110).
9617
30
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
SECONDARY
TERMINAL BOX
Terminal Box
Secondary
1
2 2
2 2
1 1 1
Terminal Boxes
Catalog
Number Hub Amps
(End Connection)
Amps (Center Connection) Dimensions Knockouts
Each Way Total D" W" H" 1 2
S1787-4X (4) C.P. 950 950 1900 14 30 42 78916
S8333-6X (6) C.P. 1500 1500 3000 24 44 52
1787
8333
Notes
• Hot Bus Support: Hot bus support and support ear available as kit for the S8333. Order kit K1822. Kit also includes
hardware to mount bus.
31
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
COMMERCIAL
PEDESTALS
Commercial Pedestals
Attractive | Easy to Install | Secure | Cost-Effective
Milbank Commercial Pedestals are pad-mounted,
weatherproof electrical enclosures consisting of
a utility pull section with optional meter socket,
and a customer section containing distribution and
control equipment. Milbank Commercial Pedestals
are an attractive, secure, easy to install and cost-
effective solution when underground remote
site power distribution and control equipment is
required, replacing unsightly and inefficient strut and
backboard structures.
UL-listed as Industrial Control Equipment (File E113855)
Strut and backboard Commercial pedestal
Type 3R rainproof, vandal-resistant cabinet of polyurethane
powder-coated steel (aluminum or stainless steel also available)
UL-listed as enclosed industrial control equipment (UL508)
Isolated lockable & sealable utility metering and lug landing
sections
Lockable customer section for distribution and control equipment
with internal deadfront
Print pocket inside customer section door contains wiring
schematics and installation instructions
Most load centers are UL-listed for use with various
manufacturers’ circuit breakers
All stainless steel external hardware (screws, bolts, hinges,
handles, hasps and sealing screws)
Standard Features
Ringless
socket
Ring type
socket
Utility lug
landing
Customer
interior
32
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
COMMERCIAL
PEDESTALS
Commercial Pedestals
Attractive | Easy to Install | Secure | Cost-Effective
These units are ideal for controlling and metering:
Traffic signals
Street lighting
Irrigation and sprinkler systems
Cell towers and telephone vaults
Pump stations
Temporary power for fairgrounds, swap meets, outdoor markets,
portable offices, holiday lights, etc.
Outdoor lighting for athletic fields, tennis and basketball courts,
parking lots, landscaping and subdivision entrances, etc.
Meter sockets: ring type or ringless, up to 400 amp
Main and branch breakers or T fuses
Distribution: copper load centers and panel boards
Clocks, timers and relays
Photoelectric cells and controls
Power receptacles: pin and sleeve, twist lock or straight blade
Contactors: definite purpose, electrical or mechanically held, IEC
and mercury types
Surge protection and lightning arrestors
Reserve inlet generator receptacle with interlocked circuit breakers
Motor starters and relays
Push button controls
Thermostat controls, fans and heating strips
Power blocks and terminal blocks
Steel, aluminum and plywood backboards
Transformers
Interlock devices for circuit breakers
Available in steel, aluminum (unpainted, painted or anodized) or
stainless steel construction with powder-coated finish available in
eight standard colors or special-ordered RAL colors
Available for applications up to 400 amp, 120V, 208V, 240V, 277V,
480V - 1Ø or 3Ø
Applications
Available Factory-Installed Options
33
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
GENERATORS Generators
Home Standby & Portable
Home Standby Generators
•7,10&12kWverticalair-cooled
•17&20kWhorizontalair-cooled
•30&45kWhorizontalliquid-cooled
•ByBriggs&Stratton
Portable Generators
•Briggs&Stratton
•Pramac(includesPowermate&DeWALT)
With over 85 years in the electrical distribution industry, Milbank is proud to offer quality
home standby and portable generator systems in partnership with Briggs & Stratton and
Pramac.
34
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
ELECTRIC
VEHICLE
SUPPLY
EQUIPMENT
Electric Vehicle Supply Equipment
Milbank | Driving the Future of Power
From a wall-mounted single dock unit in a residential garage, to a citywide municipal
integration, our scalable, flexible, reliable solution is designed for effectiveness in virtually any
installation scenario.
Level II Models
MEVSE-RS—Residential, single wall mounted; overnight at-home
charging.
MEVSE-RS Dual—Pedestal mounted with two ports; ideal for multi-
family and high-traffic commercial parking lots.
MEVSE-RS+—Available in single, dual and quad configurations with
the addition of programmable, smart charging capabilities; allows
communication with the grid for charging when energy consumption
is low; allows connectivity to GPRS.
Level III Models
DC Fast Charge — Stations feature JARI/TEPCO connectors and
CHAdeMO certification; practical networking and payment options;
available from 30-60kW models suitable for public and fleet usage;
charges in 15-30 minutes.
Suitable EV Station Locations
•Shoppingmalls
•Theatres
•Municipalbuildings
•Centralbusinessdistricts
•Entertainmentdistricts
•Stadiums&arenas
•Restareas
•Truckstops/travelplazas
•Camping/RVparks
•Restaurants
•Parkinggarages
•Publiccurbsideparking
•Ofcebuildings
•Single-familyresidences
•Multi-unitresidences
•Airports
•Hotels
•Casinos
•Anywherepeopleparkforextendedperiodsoftime
35
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Application Disconnects service at the meter.
Features
Meter stays in place to prevent tampering and to
simplify power restoration
Rotated meter shows that service has been
disconnected
Easily plugs into all new Milbank 200 amp blocks
with square fifth terminal hole
Ordering Order K4974
ACCESSORIES Accessories
Disconnect/Out of Service Devices
Disconnect Sleeve
Plug-In Out Of Service Device
Application Discretely disconnects service at the meter while
leaving the meter in place.
Features
Mylar® polyester film — flexible, durable and
stable even at extreme temperatures.
Safe, reliable and easy to install
Standard design fits most meter blades
High dielectric strength
Non-hygroscopic
Ordering Order M5-144
Installation
Guidelines
Turn off main switch or breaker before installation
Remove meter from socket
Place disconnect sleeve over load side blades
Replace meter and reseal
Do not use disconnect sleeves on lever bypass
sockets.
M5-144 disconnect sleeves
(above) shown installed on meter
blades (below)
K4974 (above); meter with K4974
installed and service disconnected
(below).
36
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
ACCESSORIES
Accessories
Hubs and Closing Plates
-R
Large hub opening
-WL A7514 -YL A7515 -ZL A7516 -DL A7517 -EL A7518 -XL A7551
1" hub 114" hub 112" hub 2" hub 212" hub Small closing
plate
-F A8110 -G A8111 -H A8112 -X A9064 -RRL S8324
3" hub 312" hub 4" hub Large closing plate Large hub opening
adapted to small
hub oepning
-RL
Small hub opening
Notes
• Suffix: Add to catalog number for factory installation of hub.
• Packaging: Individually packed units for field installation.
• Abbreviations: H.O. (hub opening), C.P. (closing plate).
37
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
ACCESSORIES Accessories
Connector Kits, Closing Covers & Sealing Rings
Connector Kits | For Use with 38"-16 Stud Type Units Only
Closing Covers
Single Twin
Suffix Part # (3 per set) - 1Ø Suffix Part # (3 per set) - 1Ø
K1 K1539 6-350 K2 K1350 6-350
K3 K1540 6-350 (non rotating) K2L K1350L 6-350 (non rotat-
ing)
K3L K1540L
4-600 or (2) 1/0-
250
(non rotating)
K4 K1541 4-600
Suffix Part # (4 per set) - 3Ø Suffix Part # (4 per set) - 3Ø
K5 K3082 6-350 K6 K3442 6-350
K7 K3441 4-600 or (2) 1/0-
250 K8 K3083 4-600
Meter Closing Plate
(Ring Type / Ringless)
Metal Closing Plate
(For Ringless Sockets)
6003 - Grey Plastic CP-21
6116 - Clear Plastic
K8180 (sold in pairs)
Allows only one
breaker to be in the
“on” position when
back-feeding with
a standby power
generator.
K5815 - large QN with small frame Q
K5820 - large frame QN with large frame QN
K5830 - small frame Q to small frame Q
Sealing Rings
MR-2 - Snap Action MR-4 - Screw Type
(Stainless Steel)
MR2-SS - Stainless
Steel
Bypass Link
Generator Interlock
38
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
ACCESSORIES
Accessories
Fifth Terminals and Tap Connectors
K1190
(For factory installed
triplex ground, add
suffix -TG to catalog
number)
Fifth Terminals
Tap Connectors (3 per set)
5T8K2 - 100-200 Amp
“Plug-In”
K5T - 200 Amp
(Block with Square Hole)
K3865 - Heavy Duty Jaw
Clamping
(K3866 without Neutral Wire)
Replaces the load or
line side slide-in nut
assembly on Milbank
200 amp sockets.
Allows for a 100 amp
tap location in addition
to the #6-350 kcmil
load-side connector.
K5022 includes safety
barrier extensions for
applications over 300
VAC. Three lugs per kit.
K4977-INT - Internal Hex (set of 3)
K4977-EXT - External Hex (set of 3)
K5022-INT - Internal Hex (set of 4 w/ barrier)
Triplex Ground
Knockout Actual Sizes
Conduit to Knockout Reference Chart
Locknut Clearances
Clearance for Locknuts on Knockouts
Conduit
Size
Milbank
Knockout
Actual Size
Milbank Knock-
out
121278
3434118
1 1 138
114114134
1121122
2 2 212
2122123
3 3 358
312312418
4 4 44164
(“D” in nearest practical dimension)
Knockout Size “D”
12118
34138
1 134
114214
112258
2 318
212312
3 414
312434
4 538
“D”
39
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Watthour Meter Forms
Standard Forms | Transformer Rated or Self-Contained
WATTHOUR
METER
FORMS
SC SC TR TR TR
TR SC SC SC SC
TR TR SC SC TR
TR TR SC SC TR
TR TR TR
2 and 3-WIRE FORMS
1S & 2S
2 and 3-WIRE FORMS
1S & 2S with BYPASS
2-WIRE FORM 3S
5th Term. 9 o'clock
2-WIRE FORM 3S
with BYPASS
2-WIRE FORM 3S
5th Te rm.6 o'clock
2-WIRE FORM 3S
with BYPASS
2 ELEMENT
3-WIRE NETWORK
FORM 12S 5th
TERM. 9 o'clock
2 ELEMENT 3-WIRE
NETWORK FORM 12S
with BYPASS
5th Term. 9 o'clock
2 ELEMENT 3-WIRE
NETWORK FORM 12S
with BYPASS
5th Te rm. 6 o'clock
2 ELEMENT
3-WIRE NETWORK
FORM 12S 5th
TERM. 6 o'clock
3-WIRE FORM 4S 3-WIRE FORM 4S
WITH BYPASS
2 or 3 ELEMENT
34W Y or
Y FORM 14S
FORM 15S
2 or 3 ELEMENT
34W Y or
FORMS 14S & 15S
with BYPASS
2 ELEMENT
34W Y or
Y FORM 7S
∆ FORM 24S
with BYPASS
2 ELEMENT
23W, 24W, 33W
FORM 5S
2 ELEMENT 23W,
24W, 33W
FORM 5S with
BYPASS
2 ELEMENT
23W, 24W, 33W
FORM 13S
2 or 3 ELEMENT
23W, 24W, 33W
FORM 13S with
BYPASS
2 or 3 ELEMENT
34W Y or
Y FORM 9S
∆ FORM 8S
2 or 3 ELEMENT
34W Y or
FORMS 8S & 9S
with BYPASS
2 ELEMENT
34W Y
FORM 6S
2 ELEMENT
34W Y
FORM 6S
with BYPASS
TR = TRANSFORMER RATED
SC = SELF CONTAINED
40
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
METER
FORMS
Meter Forms
Reference Information
+
+
I
LINE
(BONDED)
N
C.T.
LOAD
2++
DIAGRAM D
P
1
P
2
C+
1C
2
C+
2
PN
C
1
C.T.
DIAGRAM D
13W or 3W Network with 2 C.T.’s
2 Stator Meter - Form 5S
8T Socket, Test Switch #TS07-0105
+
+
1
LINE
C.T.
LOAD
2
P
1
C+
1
++
3
+
+
PT PT
DIAGRAM E
P
3
P2
C
1
C+
3
C
3
C.T.
DIAGRAM E
33W “” with 2 P.T.’s & 2 C.T.’s
2 Stator Meter - Form
5S
8T Socket, Test Switch #TS07-0105
+
+
1
LINE
C.T.
LOAD
2
P
1
C+
1
++
3
DIAGRAM F
P
3
P2
C
1
C+
3
C
3
C.T.
DIAGRAM F
33W “” with 2 C.T.’s
2 Stator Meter - Form 5S
8T Socket, Test Switch #TS07-
0105
+
+
C.T.
LOAD
P
1
+
+
P
3
P
N
C+
C+
C.T.
C.T.
++
(BONDED)
DIAGRAM G
CC
C+
C
1
LINE
2
3
N
DIAGRAM G
34W “Y” with 3 C.T.’s
2
1
2
Stator Meter - Form 6S
13T Socket, Test Switch #TS10-0109
+
+
1
LINE
C.T.
LOAD
2
P
1
+
+
3
P
3
PN
C+
N
C.T.
C.T.
++
(BONDED)
++
PT
PT
++
DIAGRAM H
C
C+
C+
C
C
DIAGRAM H
34W “Y” with 2 P.T.’s & 3 C.T.’s
2
1
2
Stator Meter - Form 6S
13T Socket, Test Switch #TS10-0109
+
+
1
LINE
C.T.
LOAD
2
P
1
+
+
3
P
3
P
N
C+
N
C.T.
C.T.
++
(BONDED)
P
2
DIAGRAM I
C
C+
C
C+
C
DIAGRAM I
34W “Y” or “” with 3 C.T.’s
“Y” 3 Stator Meter - Form 9S
” 2 Stator Meter -
Form 8S
13T Socket, Test Switch #TS10-0109
+
+
1
LINE
C.T.
LOAD
2
P
1
+
+
3
PN
C+
N
C.T.
C.T.
+
+
(BONDED)
++
PT PT
+
+
P3
PT
++
DIAGRAM J
P
2
C
C+
C
C+
C
DIAGRAM J
34W “Y” with 3 P.T.’s & 3 C.T.’s
3 Stator Meter - Form 9S
13T Socket, Test Switch #TS10-0109
DIAGRAM A
(ALT.LOC.)
+
+
+
+
I
LINE
(BONDED)
NC.T. LOAD
P
1
P
N
C+
1C1
P.T.
DIAGRAM A
12W with 1 P.T. & 1 C.T.
Single Stator Meter(2W1) - Form 3S
5T Socket, Test Switch #TS04-0101
DIAGRAM B
13W with 1 C.T.
Single Stator Meter (2W1) - Form 3S
5T Socket, Test Switch #TS04-0101
+
+
I
LINE
(BONDED)
N
C.T.
LOAD
2
P
1
P2C+
1C+
2
C
2
C+
2
++
DIAGRAM C
C.T.
DIAGRAM C
13W with 2 C.T.’s
Single Stator Meter (3W1) - Form 4S
6T Socket, Test Switch #TS07-0105
Prewiring: If standard factory prewiring is required,
refer to wiring diagrams on this page. Determine
appropriate diagram and send a copy with order.
If custom factory prewiring is required, specify on
order. Be sure to include meter socket catalog
number, test switch make and catalog number,
meter form number and provide a copy of your
wiring diagram.
41
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
materials
& finishes
Materials & Finishes
Reference Information
Materials
Finish
Ratings & Compliance
The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing.
*American Iron and Steel Institute.
Steel Quality
16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. (AISI G90)
14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.
Steel Sheet
Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire.
Bus Bar: Alloy; 6101-O & 6063-O
Aluminum Extrusion
3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064–.125
Aluminum Sheet
Electrolytic copper with tin plating in most applications.
Copper Sheet & Bus
•Inmostunits,supportbasesforcurrent-carryingcomponentsaremoldedfromfiberglassreinforcedhigh-strength,trackresistant,
thermoset polyester molding compounds.
•Clearorblacksafetyshieldsandpolaritybarriersaremoldedfromhigh-strength,trackresistant,polycarbonatemoldingcompounds.
•Varioussheetinsulatingmaterials,asappropriatefortheapplicationareutilizedinthefabricationofflat,formedandpunchedcomponent
parts and barriers.
Insulating Materials
Light gray state-of-the-art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the
chemical analysis of the weather resistant finish, please contact the factory.
Process
Zinc-coated with a chromate dip.
Metal Fastners
All Milbank electrical enclosures in this catalog are rated “Type 3R Enclosure” unless specified otherwise on the product’s page. All
enclosures with a UL designation are constructed per the appropriate UL Standard and may be installed per the National Electric Code.
UL procedure files associated with the UL Standards are listed as follows: Meter Sockets (UL 414, File E30202), Test Switches (UL 414, File
E62531), Power Outlets (UL 231, File E90945), Panelboards (UL 67, File E32628) and Pullout Switches (UL 1429, File E133062). Additional
standards are utilized as applicable: Meter Sockets (ANSI C12.7), Test Switches (ANSI C12.9) and Panelboards (NEMA PB-1).
Ratings & Compliance
42
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Product Specifications
Reference Information
Enclosure Information
Definitions Pertaining to Nonhazardous Locations | Indoor Use
Definitions Pertaining to Nonhazardous Locations | Outdoor Use
All Milbank electrical enclosures in this catalog are rated “Type 3R Electrical Enclosure” unless specified otherwise. All enclosures with a
UL designation are constructed per the appropriate UL standard and may be installed per the National Electric Code. Meter sockets are
constructed per “UL 414, Meter Sockets”, file #E30202 and per “ANSI C12.7-1993-Meter Sockets”. All test switches are constructed per “UL
414, Meter Sockets”, file #E30302 and per “ANSI C12.9-1993-Test Switches”. Power outlets are constructed per “UL 231, Power Outlets”,
file #E90945. Panelboards are constructed per “UL 67, Panelboards”, file #E32628 and “NEMA PB-1-1984-Panelboards”. Pullout switches
are constructed per “UL 1429, Pullout Switches”, file #133062.
Type 1 Enclosure
Type 1 enclosures are intended for indoor use primarily to provide a degree of protection against limited amounts of falling dirt.
Type 12 Enclosure
Type 12 enclosures are intended for indoor use primarily to provide a degree of protection against circulating dust, falling dirt and dripping
noncorrosive liquids.
Type 13 Enclosure
Type 13 enclosures are intended for indoor use primarily to provide a degree of protection against dust, spraying of water, oil and
noncorrosive coolant.
Type 3 Enclosure
Type 3 enclosures are intended for outdoor use primarily to provide a degree of protection against rain, sleet, windblown dust and damage
from external ice formation.
Type 3R Enclosure
Type 3R enclosures are intended for outdoor use primarily to provide a degree of protection against rain, sleet and damage from external
ice formation.
Type 4 Enclosure
Type 4 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain,
splashing water, hose-directed water and damage from external ice formation.
Type 4X Enclosure
Type 4X enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust
and rain, splashing water, hose-directed water and damage from external ice formation.
Milbank Electrical Meter Enclosures Specification Note
43
PRODUCT
SPECIFICATIONS
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
INDEX Index
44
6003....................................................38
6116....................................................38
363010-CT3R ......................................22
363016-CT3R ......................................22
363610-CT3R ......................................22
363612-CT3R ......................................22
363616-CT3R ......................................22
483616-CT3R ......................................22
484812-CT3R ......................................22
5T8K2 .................................................39
606013-CT3R ......................................22
A7514 .................................................37
A7515 .................................................37
A7516 .................................................37
A7517 .................................................37
A7518 .................................................37
A7551 .................................................37
A8110 .................................................37
A8111 .................................................37
A8112 .................................................37
A9064 .................................................37
AP2300-03 ............................................ 4
AP2300-03-5T .......................................4
AP2300-03-5T-AB .................................4
AP2300-03-6T .......................................4
AP2300-04 ............................................ 4
AP2300-07 ............................................ 4
AP2300-08 ............................................ 4
CP-21 .................................................. 38
CT244811-HC .....................................24
CT244811-SC .....................................24
CT304811-HC .....................................24
CT304811-SC .....................................24
CT364811-HC .....................................24
CT364811-SC .....................................24
K1190 .................................................39
K1350 .................................................38
K1350L ...............................................38
K1539 .................................................38
K1540 .................................................38
K1540L ...............................................38
K1541 .................................................38
K3082 .................................................38
K3083 .................................................38
K3441 .................................................38
K3442 .................................................38
K3865 .................................................39
K3866 .................................................39
K4722 .................................................24
K4729 .................................................24
K4797 .................................................24
K4798 .................................................24
K4974 .................................................36
K4977-EXT ..........................................39
K4977-INT ..........................................39
K5022-INT ..........................................39
K5815 .................................................38
K5820 .................................................38
K5830 .................................................38
K5T .....................................................39
K8180 .................................................38
M5-144 ...............................................36
MR-2 ...................................................38
MR2-SS ...............................................38
MR-4 ...................................................38
NU8980-O ..........................................26
NU8980-O-2002 ................................. 26
NU8980-O-SF100 ............................... 26
PT48AL ...............................................22
PT48AR ............................................... 22
PT48L ..................................................22
PT48R .................................................22
S1787-4X ............................................31
S1890-XT ............................................25
S1891-XT ............................................25
S1910-YL ..............................................8
S2417-DL .............................................. 8
S2417-RL ..............................................8
S2674-XT ............................................25
S2690-XT ............................................25
S3831-XT ............................................25
S3912-XT ............................................25
S4275-DL .............................................. 8
S4339-RL ..............................................8
S8324..................................................37
S8333-6X ............................................31
TS04-0101 ..........................................21
TS04-0104 ..........................................21
TS07-0049 ..........................................21
TS07-0105 ..........................................21
TS07-0106 ..........................................21
TS10-0016 ..........................................21
TS10-0109 ..........................................21
TS10-0110 ..........................................21
TS10-0111 ..........................................21
TS10-0112 ..........................................21
U1797-O-K2L-K3L ..............................11
U3328-RXL ............................................8
U4363-R .............................................. 11
U4505-X ..............................................11
U4540-XL ............................................ 30
U4542-XL ............................................ 30
U4544-XL ............................................ 30
U4546-XL ............................................ 30
U4548-RXL ..........................................30
U4549-RXL ..........................................30
U5000-XL ............................................ 28
U5000-XL-41 .......................................28
U5000-XL-55 .......................................28
U5000-XL-75 .......................................28
U5100-XL ............................................ 28
U5100-XL-41 .......................................28
U5100-XL-55 .......................................28
U5100-XL-75 .......................................28
U5136-O-100S ....................................27
U5136-O-200S ....................................27
U5137-O-200S ....................................27
U5168-XTL-100 ...................................13
U5168-XTL-200 ...................................13
U5169-XTL-100 ...................................13
U5169-XTL-200 ...................................13
U5200-XL ............................................ 29
U5200-XL-41 .......................................29
U5200-XL-55 .......................................29
U5200-XL-75 .......................................29
U5220-XL ............................................ 29
U5220-XL-41 .......................................29
U5220-XL-55 .......................................29
U5220-XL-75 .......................................29
U5300-O ............................................. 29
U5300-O-41 ........................................29
U5300-O-55 ........................................29
U5300-O-75 ........................................29
U5320-O ............................................. 29
U5320-O-41 ........................................29
U5320-O-55 ........................................29
U5320-O-75 ........................................29
U5764-X-200-CB ................................15
U5765-X-200-CB ................................15
U5767-X-200-CB ................................15
U5784-O-200-CB ................................15
U5787-O-200-CB ................................15
U5796-X-400-CB ................................15
U5797-O-400-CB ................................15
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
INDEX
Index 45
U5799-O-400-CB ................................15
U5842-PXL-200 ...................................12
U5842-RL ............................................ 12
U5842-RL-100 ..................................... 12
U5844-PXL-200 ...................................12
U5852-RL ............................................ 12
U5852-RL-100 ..................................... 12
U5852-RL-200 ..................................... 12
U5854-RL-200 ..................................... 12
U5882-X ..............................................17
U5883-X ..............................................17
U5884-X ..............................................17
U5885-X ..............................................17
U5886-X ..............................................17
U5890-X-2/200 ...................................14
U5891-X-2/200 ...................................14
U5892-X-2/200 ...................................14
U5893-X-2/200 ...................................14
U5894-X-2/200 ...................................14
U5895-X-2/200 ...................................14
U5902-X ..............................................17
U5903-X ..............................................17
U5904-X ..............................................17
U5905-X ..............................................17
U5906-X ..............................................17
U5929-XL .............................................. 5
U5934-XL .............................................. 5
U7017-DL-TG .......................................7
U7017-RL-TG ........................................ 7
U7017-RL-TG-5T ...................................7
U7018-XL-TG ........................................ 7
U7021-DL-TG .......................................6
U7021-RL-TG ........................................ 6
U7021-RL-TG-5T ...................................6
U7040-RL-TG ........................................ 6
U7420-RL .............................................. 9
U7421-RL .............................................. 9
U7422-RXL ............................................9
U7423-RXL ............................................9
U7487-RL-TG ........................................ 5
U7487-RL-TG-5T ...................................5
U7490-YL-TG ........................................ 5
U7490-YL-TG-5T ...................................5
U8212-RL ............................................ 16
U8213-RL ............................................ 16
U8214-RL ............................................ 16
U8215-RL ............................................ 16
U8216-XL ............................................ 16
U8436-O ............................................. 26
U9700-RRL ............................................ 9
U9701-RXL ............................................9
UAP5024-XL .......................................13
UC1299-RL .........................................18
UC1300-XL .........................................18
UC5087-RL .........................................19
UC5732-XL .........................................18
UC7235-RL .........................................18
UC7237-RL .........................................18
UC7444-RL .........................................19
UC7445-RL .........................................19
UC7448-RL .........................................19
UC7449-RL .........................................19
UC7478-RL .........................................19
UC7532-RL .........................................19
UC7544-XL .........................................18
UC7545-XL .........................................18
UCSS3433-O ......................................10
UCSS3436-O ......................................10
UCSS3438-O ......................................10
USS3914-O ......................................... 10
USS4701-O ......................................... 10
USS4801-O ......................................... 10
USS4801-O-5T9 ..................................10
46
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
NOTES Notes
47
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com
NOTES
Notes
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com INTERNATIONAL 3/13

Navigation menu