658794 Catalog

126428-Catalog 126428-Catalog 126428-Catalog 784572 Batch10 unilog cesco-content

2014-10-17

: Pdf 658794-Catalog 658794-Catalog 784572 Batch10 unilog

Open the PDF directly: View PDF PDF.
Page Count: 48

Download658794-Catalog
Open PDF In BrowserView PDF
International Catalog
Metering Equipment

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

2

About Milbank

ABOUT
MILBANK

Energy at work since 1927

Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation
sectors. Milbank combines more than 85 years of expertise in electrical engineering design and manufacturing
with a commitment to develop and globally implement sustainable, integrated power solutions. Milbank’s
portfolio includes electric metering systems, PowerGen™ wind and solar solutions, and portable power. A thirdgeneration, family-owned business, Milbank is headquartered in Kansas City, Mo. For more information, please
visit milbankworks.com.

METERING
Milbank meter sockets have set the standard for quality since
1927. With a 99.97% quality performance, thousands of
active products to meet your utility’s requirements and tens of
millions of sockets installed across the globe, our products help
keep energy at work. And with 22 stocking locations across the
U.S., and our OneSERT program to help during emergency
situations, our meter sockets are ready to go, wherever the job
may be.

COMMERCIAL & INDUSTRIAL
When it comes to commercial and industrial products, Milbank
has it covered! We offer a complete line of junction boxes,
telephone cabinet covers, transformer cabinets, wireways,
pushbutton enclosures, consoles and thermal management
products. We specialize in custom-built enclosures and are
more than happy to design a solution for your specific project.
Our commercial meter pedestals are easy to install, fast, safe
and secure, and completely customizable.

POWERGEN
Milbank’s standby and portable generators give you the peace
of mind of living life uninterrupted during increasingly frequent
power outages caused by severe weather, high demand and
other situations. Our electric vehicle supply equipment, wind
turbines and power management systems give you reliable and
sustainable ways to reduce both your energy costs and your
impact on the environment.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

Table of Contents
See back of catalog for index by catalog number

3

TABLE OF
CONTENTS

Single Position Meter Sockets
Economy socket, 4–6 terminals, ring type......................................................................................................................... 4
100–125 amps, 4 & 5 terminals, ringless & ring type........................................................................................................ 5
200 amps, 4 & 5 terminals, ringless & ring type............................................................................................................ 6–7
100–200 amps, 7 terminals, ringless & ring type............................................................................................................... 8
200 amps, 7 terminals, ringless.......................................................................................................................................... 9
Stainless steel meter sockets........................................................................................................................................... 10
320 amps, 4 & 5 terminals, lever bypass, ringless........................................................................................................... 11

Meter Mains
100–200 amps, 4 terminals, ringless................................................................................................................................
100–200 amps, with load center, 4 terminals, ringless & ring type.................................................................................
320 amps, 4 terminals, lever bypass, ringless..................................................................................................................
Cold sqeuence, 4–7 terminals, ringless............................................................................................................................

12
13
14
15

Multi-Position
100 amps, 5 terminals, ringless........................................................................................................................................ 16
Meter mains, 125 & 200 amps, 4 terminals, ringless....................................................................................................... 17

Transformer Rated, Test Switches, Transformer Cabinets & Transockets
20 amps, 6–15 terminals, ringless & ring type........................................................................................................... 18–19
Test switches............................................................................................................................................................. 20–22
Transformer cabinets................................................................................................................................................. 23–24
600 amp transockets, 6–14 terminals, ringless................................................................................................................ 25

Pedestals
100–200 amps, meter main pedestals, 4 terminals, ringless............................................................................................ 26
100–200 amps, meter main with load center pedestals, 4 terminals, ringless................................................................. 27

Power Outlets/RV Power
Surface mount power outlets.......................................................................................................................................... 28
Power outlet pedestals.................................................................................................................................................... 29

Miscellaneous
Terminal boxes.......................................................................................................................................................... 30–31
Commercial meter pedestals..................................................................................................................................... 32–33
Generators....................................................................................................................................................................... 34
Electric vehicle supply equipment................................................................................................................................... 35
Accessories................................................................................................................................................................ 36–39
Reference information............................................................................................................................................... 40–43

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

4

Economy Socket

economy
socket

4–6 Terminals | 100 Amps | Ring Type

30-100 Amps | 4, 5 & 6 Terminals | Economy Cast Socket | Ring Type
Catalog Number

Terminals

Hub
Location

Hub
Size

Connectors CU/AL

Quantity
per Package

AP2300-03

4

Top & Bottom

(2) 1"

#12-#1

12

3

AP2300-04

4

Top & Bottom

1

(2) 1 ⁄4"

#12-#1

12

3

AP2300-07

4

Top

1"

#12-#1

12

3

AP2300-08

4

Top

11⁄4"

#12-#1

12

3

AP2300-03-5T

5

Top & Bottom

(2) 1"

#12-#1

12

3

AP2300-03-5T-AB

5

Top & Bottom

(2) 1"

#12-#1

12

3

AP2300-03-6T

6

Top & Bottom

(2) 1"

#12-#1

12

3

Knockouts
⁄4", 1"
⁄4", 1"
⁄4", 1"
⁄4", 1"
⁄4", 1"
⁄4", 1"
⁄4", 1"

Notes
• Non-UL Listed: These units are not UL tested.
• Fifth Terminal: AP2300-03-5T and AP2300-03-5T-AB include factory-installed fifth terminal
• Sixth Terminal: AP2300-03-6T includes factory-installed sixth terminal.
• Auto-Bypass: -AB suffix indicates installed auto-bypass feature. Consult factory for more details.
• Sealing Rings: These units are supplied with an MR-2 snap action sealing ring as standard.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

5

Single Position Sockets

100–125 AMP
SINGLE
POSITION
SOCKETS

100–125 Amps | Ringless & Ring Type | 600 VAC

1

3

2

1

2

3

7487

3

2

5929
5934
7490

3

1
4

4

U7487-RL-TG

U5934-XL

U7490-RL-TG
SOLAR-FRIENDLY

4 & 5 Terminals | Single Position | Ringless
Catalog Number Amps Terminals Hub

Connectors CU/AL

Bypass

Dimensions

Knockouts

Line

Load

D"

W"

H"

1

U7487-RL-TG

125

4

H.O.

#6-2/0

#6-2/0

None

35⁄16

8

111⁄2

2

11⁄2 11⁄4

1

U5934-XL

100

4

C.P.

#6-2/0

#6-2/0

None

5

3 ⁄16

8

11 ⁄2

2

1 ⁄2 1 ⁄4

1

U7487-RL-TG-5T

125

5

H.O.

#12-1/0

#12-1/0

None

3 ⁄16

8

11 ⁄2

2

1 ⁄2 1 ⁄4

1

5

1
1

2
1
1

3
1
1

4
⁄4
⁄4
⁄4

4 & 5 Terminals | Single Position | Ring Type
Catalog Number Amps Terminals Hub

Connectors CU/AL

Bypass

Dimensions

Knockouts

Line

Load

D"

W"

H"

1

U7490-YL-TG

125

4

11⁄4"

#6-2/0

#6-2/0

None

35⁄16

8

111⁄2

2

11⁄2 11⁄4

1

U5929-XL

100

4

C.P.

#6-2/0

#6-2/0

None

5

3 ⁄16

8

11 ⁄2

2

1 ⁄2 1 ⁄4

1

U7490-YL-TG-5T

125

5

1 ⁄4"

#12-1/0

#12-1/0

None

3 ⁄16

8

11 ⁄2

2

1 ⁄2 1 ⁄4

1

1

5

1
1

2
1
1

3
1
1

4
⁄4
⁄4
⁄4

Notes
• Aluminum: These units are also available in aluminum. Consult factory for more details.
• Fifth Terminal: For field mounted fifth terminal on the U7487 & U7490 order catalog number 5T8K2 to fit into round
	 opening at the 9 o’clock position. For factory-installed fifth terminal, add -5T to the catalog number.
• Hubs: For proper hub selection see the hub suffix chart on the accessory page.
• Connectors: Extruded aluminum connectors are tin plated.
• Sealing Rings: The U7490 unit is supplied with an MR-2 snap action sealing ring as standard.
• Horn Bypass: Horn bypass is available—contact factory for details.
• Isolated Neutral: U5929 and U5934 include isolated neutral option, ideal for solar applications.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

6

Single Position Sockets

200 amp
single
position
sockets

200 Amps | 4 & 5 Terminals | Ringless | 600 VAC

1

3

1

2

1

1

1

7021

1

1
2

U7021-RL-TG

1

7040

3

U7040-RL-TG

200 Amps | 4 & 5 Terminals | Single Position | Ringless
Catalog Number

Terminals

Hub

Connectors CU/AL

Dimensions

Knockouts

Line

Load

D"

W"

H"

1

1

2

3

U7021-RL-TG

4

H.O.

#6-350

#6-350

4 ⁄8

8

15 ⁄2

2 ⁄2

1

⁄4, ⁄2

1

U7021-DL-TG

4

2"

#6-350

#6-350

41⁄8

8

151⁄2

21⁄2

1

⁄4,1⁄2

1

U7040-RL-TG

4

H.O.

#6-350

#6-350

1

4 ⁄8

11

14 ⁄8

1

2 ⁄2

1

1

⁄4, ⁄2

1

U7021-RL-TG-5T

5

H.O.

#6-350

#6-350

4 ⁄8

8

15 ⁄2

2 ⁄2

1

⁄4, ⁄2

1

1

1

5
1

1

1

1

1

⁄4
⁄4
⁄4
⁄4

Notes
• Other Options: These units are also available in aluminum and horn bypass. Consult factory for more details.
• Fifth Terminal: For field mounted fifth terminal, order catalog number K5T to fit into square opening at the 9 o’clock
	 position. For factory-installed fifth terminal, add suffix -5T to catalog number.
• Triplex Ground (-TG): factory installed.
• Connectors: Extruded aluminum connectors are tin plated.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

7

Single Position Sockets

200 AMP
SINGLE
POSITION
SOCKETS

200 Amps | 4 & 5 Terminals | Ring Type | 600 VAC

1

3

1

1

1

2

7017

1

1
2

U7017-RL-TG

1

1
3

U7018-XL-TG

200 Amps | 4 & 5 Terminals | Single Position | Ring Type
Catalog Number Terminals

Hub

Connectors CU/AL

Dimensions

Knockouts

Line

Load

D"

W"

H"

1

1

2

3

U7017-RL-TG

4

H.O.

#6-350

#6-350

4 ⁄8

8

15 ⁄2

2 ⁄2

1

⁄4, ⁄2

1

U7017-DL-TG

4

2"

#6-350

#6-350

1

4 ⁄8

8

15 ⁄2

1

2 ⁄2

1

1

⁄4, ⁄2

1

U7018-XL-TG

4

C.P.

#6-350

#6-350

43⁄16

111⁄8

151⁄2

21⁄2

1

⁄4,1⁄2

1

U7017-RL-TG-5T

5

H.O.

#6-350

#6-350

4 ⁄8

8

15 ⁄2

2 ⁄2

1

⁄4, ⁄2

1

1

1
1

1

1

1

1

1

⁄4
⁄4
⁄4
⁄4

Notes
• Other Options: These units are also available in aluminum and horn bypass. Consult factory for more details.
• Fifth Terminal: For field mounted fifth terminal, order catalog number K5T to fit into square opening at the 9 o’clock
	position.
• Triplex Ground (-TG): factory installed.
• Connectors: Extruded aluminum connectors are tin plated.
• Sealing Rings: Units on this page are supplied with an MR-2 snap action sealing ring as standard.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

7018

8

Single Position Sockets

100–200 amp
single
position
sockets

100–200 Amps | 7 Terminals | Ringless | 600 VAC

S2417-RL

S1910-YL

2

1

2

3

1

1910
4339

1

1

2417

2 3

2

U3328-RXL

S4339-Rl

1

3

4

1

1

4275

2

1

2

1
4

1

3328

3

7 Terminals | Single Position | Ringless
Connectors CU/AL

Dimensions

Bypass

Knockouts

Catalog Number

Amps

Hub

Line

Load

D"

W"

H"

1

2

S1910-YL

100

11⁄4"

#6-2/0

#6-2/0

None

35⁄16

8

111⁄2

2

11⁄2

1

S2417-RL

200

H.O.

#6-350

#6-350

None

5

3 ⁄16

8

11 ⁄2

2

1

1 ⁄2

1

S2417-DL

200

2"

#6-350

#6-350

None

3 ⁄16

8

11 ⁄2

2

1 ⁄2

1

5

1
1

3
⁄4
⁄4
⁄4

1

7 Terminals | Single Position | Ring Type
Catalog Number Amps

Hub

Connectors CU/AL
Line

Load

Bypass

Dimensions

Knockouts

D"

W"

H"

1

2

5

S4339-RL

100

H.O.

#6-2/0

#6-2/0

None

3 ⁄16

8

11 ⁄2

2

S4275-DL

200

2"

#6-350

#6-350

None

41⁄8

8

151⁄2

21⁄2

U3328-RXL

200

C.P.

#6-350

#6-350

None

4 ⁄8

13

19

3

7

1

3

4

⁄4

—

⁄4

—

1

1 ⁄2

1

⁄4,1⁄2

1

1

2 ⁄2
1

⁄4, ⁄2

1

1

⁄4

1

Notes
• U3328-RXL: For isolated neutral, order K1047.
• Sealing Rings: Ring type units are supplied with an MR-2 snap action sealing ring as standard.
•	Aluminum Option: Products on this page are available in aluminum shell construction. Contact Milbank for details.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

9

Single Position Sockets

200 amp
single
position
sockets

200 Amps | 7 Terminals | Ringless | 600 VAC

3
1

4

1

2
3

1

7420
7421
9700

1

2

1
4

U7421-RL

7422
7423
9701

1
3

U9700-RRL

200 Amps | 7 Terminals | Single Position | Ringless
Catalog Number

Hub

U7420-RL
U7421-RL

Connectors CU/AL
Line

Load

H.O.

#6-350

H.O.

U7422-RXL†
†

†

Bypass

Dimensions

Knockouts

D"

W"

H"

1

2

#6-350

None

1

7

4 ⁄8

10

18 ⁄2

#6-350

#6-350

Lever 2

47⁄8

10

C.P.

#6-350

#6-350

None 1

47⁄8

U7423-RXL

C.P.

#6-350

#6-350

Lever

2

7

U9700-RRL

H.O.

#6-350

#6-350

Lever

3

U9701-RXL†

C.P.

#6-350

#6-350

Lever 3

3

4

3

1

2 ⁄2

3

⁄4

1

181⁄2

3

21⁄2

3

⁄4

1

13

19

3

21⁄2

1

⁄4,1⁄2

1

⁄4

4 ⁄8

13

19

3

2 ⁄2

1

⁄4, ⁄2

1

⁄4

7

4 ⁄8

10

1

18 ⁄2

3

2 ⁄2

47⁄8

13

19

3

21⁄2

1

1

1

⁄4,1⁄2

1

3

1

⁄4,1⁄2

⁄4

⁄4,1⁄2

⁄4,1⁄2

1

⁄4

1

Notes
These units have a large hub opening with reducer plate to small hub opening.
• Bypass: 1 Medium duty, no bypass. 2 Medium duty lever bypass, non jaw-clamping. 3 Lever supplies clamping action on
	 meter spades and also operates bypass device.
•	Aluminum Option: Products on this page are available in aluminum.
•	4 & 5 Terminal Option: These units are also available in 4 & 5 terminals.
†

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

10

Stainless Steel Products

STAINLESS
STEEL
PRODUCTS

Build to endure extreme environments

USS4701-O

UCSS3433-O

200 Amps | Single Position | Stainless Steel | Ringless
Connectors CU/AL

Dimensions

Catalog
Number

Terminals

Hub

Line

Load

D"

W"

H"

USS3914-O

4

Blank

#6-350

#6-350

None

47⁄8

13

19

USS4801-O

4

Blank

#6-350

#6-350

Lever

7

4 ⁄8

13

19

USS4801-O-5T9

5

Blank

#6-350

#6-350

Lever

7

4 ⁄8

13

19

USS4701-O

7

Blank

#6-350

#6-350

Lever

47⁄8

13

19

Bypass

Transformer Rated | With Provisions for Test Switch | Stainless Steel | Ring Type
Dimensions

Catalog Number

Terminals

Hub

Connectors CU

Bypass

D"

W"

H"

UCSS3436-O

6

Blank

#14 - 2

Test Switch*

51⁄8

12

20

UCSS3438-O

8

Blank

#14 - 2

Test Switch*

1

5 ⁄8

12

20

UCSS3433-O

13

Blank

#14 - 2

Test Switch*

5 ⁄8

12

20

1

Notes
• Conduit Opening Applications: All conduit openings have dimples provided to center location. Top conduit
	 opening must have water-tight hub installed.
• *Test Switch: Test switch provisions. Test switch and wiring not included.
• Contact Milbank for other units available in stainless steel.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

11

Single Position Lever Bypass

320 amp
single
position
lever bypass

320 Amp | 4 & 5 Terminal | Ringless | 600 VAC

1

1

1
3

1

1

1 1
3 2

4505

1

4363

1

1

2

1
1 1 1
3 2

1

1797

U4363-R

U1797-O-K2L-K3L

320 Amps | 4 & 5 Terminals | Single Position | Ringless
Catalog Number

Terminals

Hub

U4363-R*

4

H.O.

U1797-O-K2L-K3L

4

Blank

U4505-X

5

C.P.

Connectors CU/AL
Line
⁄8" x 16 Stud

3

(1) #4-600 or
(2) 1/0-250

⁄8" x 16 Stud

3

Load

Bypass

Dimensions

Knockouts

D"

W"

H"

1

7

2

3

⁄8” x 16 Stud

Lever

4 ⁄8

13

28 ⁄4

3

1

⁄4, ⁄2

1

Twin #6-350

Lever

47⁄8

13

281⁄4

3

1

⁄4,1⁄2

1

⁄4

⁄8” x 16 Stud

Lever

4 ⁄8

15

28 ⁄4

3

1

⁄4, ⁄2

1

⁄4

3

3

7

1

1

1

⁄4

1

Notes
• *UL Listing: This product is UL listed for parallel 250 conductors only. Use K1450 with (2) 250 conductors.
• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.
• Connectors: U1797 includes lugs. U4363 and U4505 are supplied with 3⁄8"-16 hex head nuts with Belleville washers. For
	 connector lug kits, order as extra from chart on accessories page. Separate lug kits are required for line and load.
•	Bypass: Lever supplies clamping action on meter spades and also operates bypass device.
•	Fifth Terminal: For field-installed fifth terminal for U4363 and U1797, order K3865.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

12

100–200 amp
meter mains

Meter Mains
100–200 Amps | 4 Terminals | Ringless | 120/240 VAC

1

3

1 2

1
1

5842
5852

4
3

2

2
2
5

4

34

3

2

5844

3

2

1
6

34

5

5
4

3

5854
4 5

U5844-PXL-200

U5842-RL-100
4 Terminals | Meter Mains | Ringless
Catalog Number

Service

Hub

U5842-RL

OH

Connectors CU/AL
Line

Load

H.O.

#6-350

—

Bypass

†

Dimensions

Knockouts

D"

W"

H"

1

None

1

4 ⁄8

8

1

2

3

4

5

1

⁄4, ⁄2

1

⁄4

—

—

1

⁄4, ⁄2

1

⁄4

—

—

⁄4,1⁄2

1

⁄4

—

2 ⁄2

1

30

1

2 ⁄2

1

1

U5842-RL-100

OH

H.O.

#6-350

CB - 100A

None

4 ⁄8

8

30

2 ⁄2

1

U5842-PXL-200

OH

C.P.

#6-350

CB - 200A

None

41⁄8

8

30

21⁄2

1

U5844-PXL-200

OH/UG

C.P.

#6-350

CB - 200A

None

4 ⁄2

14

30

3

1

1

⁄2, ⁄4

1

3

—
⁄4,1⁄2

1

4 Terminals | Meter Mains | Ring Type
Catalog Number

Service Hub

Connectors CU/AL
Line

Load

Bypass

Dimensions

Knockouts

D"

W"

H"

1

1

2

3

4

5

6

1

⁄4, ⁄2

1

⁄4

—

—

—

1

⁄4, ⁄2

1

⁄4

—

—

—

⁄4,1⁄2

1

⁄4

—

—

2 ⁄2

2

1

U5852-RL

OH

H.O.

#6-350

—

None

4 ⁄8

8

30

2 ⁄2

1

U5852-RL-100

OH

H.O.

#6-350

CB - 100A

None

1

4 ⁄8

8

30

1

2 ⁄2

1

U5852-RL-200

OH

H.O.

#6-350

CB - 200A

None

41⁄8

14

30

21⁄2

1

OH/UG H.O.

#6-350

CB - 200A

None

4 ⁄2 14 ⁄4

30

3

U5854-RL-200

†

1

1

1

1

⁄2, ⁄4

1

3

—
⁄4,1⁄2

1

Notes
Breaker not included
•	AIC Rating: All models are rated 22K AIC when using Siemens QPH (100A) or QNH (200A) breakers.
•	Hub: -PXL versions supplied with one (1) closing plate packed inside. Order other hubs separately.
•	Fifth Terminal: For field installable fifth terminal kit, order K5T.
†	

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

13

Meter Main with Load Center

100–200 AMP
meter main
w/ load center

100–200 Amps | 4 Terminals | 120/240 VAC

3 3
1

2

5

6

3 6 3

5
4

45

3

3
1

5168
5169

2
6

5024

5
4 5

UAP5024-XL

U5168-XTL-200
4 Terminals | Meter Mains | Ringless
Catalog Number Amps Service Circuits Hub

Connectors
CU/AL - Line

Dimensions
D"

Knockouts

W"

H"

1

2

3

4

1

5

U5168-XTL-100

100

OH/UG

10

C.P.

#6-350

4 ⁄2 14 ⁄8

30

3

2 ⁄2

2

1

1

U5168-XTL-200

200

OH/UG

8

C.P.

#6-350

41⁄2 141⁄8

30

3

21⁄2

2

1

1

UAP5024-XL

200

OH/UG

12

C.P.

#6-350

41⁄2 141⁄8

24

3

21⁄2

2

1

1

1

1

6

3

⁄2, ⁄4

1

⁄4,1⁄2

⁄2,3⁄4

1

⁄2,3⁄4

1

⁄4,1⁄2
⁄4,1⁄2

4 Terminals | Meter Mains | Ring Type
Catalog Number Amps Service Circuits Hub

Connectors
CU/AL - Line

Dimensions
D"

Knockouts

W"

H"

1

2

3

4

1

5

U5169-XTL-100

100

OH/UG

10

C.P.

#6-350

4 ⁄2 14 ⁄8

30

3

2 ⁄2

2

1

1

U5169-XTL-200

200

OH/UG

8

C.P.

#6-350

41⁄2 141⁄8

30

3

21⁄2

2

1

1

1

1

6

3

⁄2, ⁄4

1

⁄4,1⁄2

⁄2,3⁄4

1

⁄4,1⁄2

Notes
• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.
• Fifth Terminal: For field installed fifth terminal, order K5T.
• Interlock Kit: For generator auxiliary circuit breaker interlock, order K5815 for large QN with small frame Q; order K5820
	 for large frame QN with large frame QN; order K5830 for small frame Q to small frame Q. See accessories page for details.
• UAP5024-XL: This unit is painted aluminum. Breaker section has provision for six double pole “plug-in” type circuit 	
	 breakers. All circuit breakers will be parallel. To comply with NEC wire bending space requirements, the maximum breaker 	
	 amperage is 200 amps restricted to 3/0 copper conductor.

Plug-In Breaker Compatibility Chart
Amps

Cutler Hammer

Siemens

General Electric

Square D

150-200

BR, BRH, HQP, QPHW, QPGF, QPHGF

QP, QPH

THQL, THHQL, THQL-GF, THHQL-GF

Homeline

≤ 125

QP / BR

QP, QPH

THQ

Homeline

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

14

Lever Bypass Meter Mains

320 amp
lever bypass
meter main

320 Amps | 4 Terminals | Ringless | 120/240 VAC

1

2

2

2

2

5890
5893

3

U5890-X-2/200

1

2

2

2

2

34

43

3 4

5891
5892
5894
5895

5

U5894-X-2/200

320 Amps | 4 Terminals | Meter Mains | Lever Bypass | Ringless
Catalog Number

Service

Hub

Side
Wireway

U5890-X-2/200

OH/UG

C.P.

No

3

U5891-X-2/200

OH/UG

C.P.

No

3

Dimensions

Knockouts

Connectors
CU/AL - Line

Branch
Circuits

D"

W"

H"

1

2

⁄8" x 16 Studs

N/A

6

241⁄2

35

4

21⁄2

1

⁄8" x 16 Studs

12

6

291⁄2

35

4

21⁄2

1

1

⁄8" x 16 Studs

24

6

29 ⁄2

35

4

2 ⁄2

1

1

⁄8" x 16 Studs

N/A

6

241⁄2

35

4

21⁄2

1

⁄8" x 16 Studs

12

6

291⁄2

35

4

21⁄2

1

1

⁄8" x 16 Studs

24

6

29 ⁄2

35

4

2 ⁄2

1

1

U5892-X-2/200

OH/UG

C.P.

No

3

U5893-X-2/200

OH/UG

C.P.

Yes

3

U5894-X-2/200

OH/UG

C.P.

Yes

3

U5895-X-2/200

OH/UG

C.P.

Yes

3

1

1

1

1

3

4

5

⁄4

—

—

⁄2,3⁄4

1

⁄4

⁄2, ⁄4

1

⁄4

—

—

⁄2,3⁄4

1

⁄4

⁄2, ⁄4

1

⁄4

⁄4

3

3

Notes
• Hubs: For proper hub selection refer to the hub suffix chart on the accessory page.
• Breakers: All units come with two 200A main breakers.
• Side Bussed Units: U5893, U5894 and U5895.
• -MLK: Main Lug feed-through kit K3701 factory installed on U5891 and U5894.
• Fifth Terminal: For field mounted fifth terminal order catalog number K3865.
• Connectors: Socket is supplied with 3/8” - 16 hex head nuts with Belleville washers. For connector lug kits, order as extra
	 from chart on accessories page. Separate lug kits are required for line side only.

Plug-In Breaker Compatibility Chart
Amps

Cutler Hammer

Siemens

General Electric

Square D

150-200

BR, BRH, HQP, QPHW, QPGF, QPHGF

QP, QPH

THQL, THHQL, THQL-GF, THHQL-GF

Homeline

≤ 125

QP / BR

QP, QPH

THQ

Homeline

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

15

Cold Sequence Meter Mains

cold
sequence
meter mains

4, 5 & 7 Terminals | Ringless

1

1

5796

2 1 2
4 3

U5767-X-200-CB

U5787-O-200-CB

1
1
1 1 1
3 2

1

1

2

5764 5767
5765

1

3

2

1

2

4

4

1

1

2
3

5784
5787

1

1

2
3

2 2

1

1

4

2
3

5797
5799

200 Amp Circuit Breaker Disconnect Ahead Of Meter Socket
Connectors CU/AL

Catalog Number

Terminals

Service

Hub

U5764-X-200-CB

4

OH/UG

C.P.

#6-350

U5765-X-200-CB

5

OH/UG

C.P.

U5784-O-200-CB

5

UG

U5767-X-200-CB

7

U5787-O-200-CB

7

Line & Load

Bypass

Dimensions

Knockouts

D"

W"

H"

1

2

Lever

27

4 ⁄32

13

43

4

2 ⁄2

1

#6-350

Lever

27

4 ⁄32

13

43

4

2 ⁄2

1

Blank

#6-350

Lever

427⁄32

26

28

4

21⁄2

1

OH/UG

C.P.

#6-350

Lever

27

4 ⁄32

13

43

4

1

2 ⁄2

1

1

UG

Blank

#6-350

Lever

6

26

28

4

21⁄2

1

1

1

1

3

4

⁄4

—
⁄2 , 3⁄4

1

⁄4

—
⁄2 , 3⁄4
⁄2 , 3⁄4

400 Amp (320 Amp Continuous) Circuit Breaker Disconnect Ahead Of Meter Socket
Catalog Number

Terminals

Service

Hub

U5797-O-400-CB

5

UG

U5796-X-400-CB

7

U5799-O-400-CB

7

Connectors CU/AL
Line

Load

Blank

3/0-500

3/0-500

OH/UG

C.P.

3/0-500

UG

Blank

3/0-500

Bypass

Dimensions

Knockouts

D"

W"

H"

1

2

3

Lever

6

26

36

4

2 ⁄2

1

3/0-500

Lever

6

13

56

4

21⁄2

1

3/0-500

Lever

6

26

36

4

21⁄2

1

Notes
• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

1

4
1

⁄2 , 3⁄4

1

⁄2 , 3⁄4

⁄4

—

16

Multi-Position Sockets

100 amp
multiposition

100 Amps | 4 Terminals | 300 VAC

1

3

2

2

2

2

2

2

2

3

8212

U8212-RL

2

2

2

1 3 2

2

2 3

2

2

8213

2

2

2

2

2

1 3 2

2

2

2

2 3 1

1 3 2 3

2

8215

2 3

2

3 2

3 2 3

2

1

8214

2

2

2

2

2

2

1 3 2

2

2

2

2

2 3 1

2

8216

100 Amps per Position | 4 Terminal | Multi-Position | Ringless
Catalog
Number

Positions Hub

Connectors CU/AL

Dimensions

Knockouts

Line

Load

D"

W"

H"

1

2

U8212-RL

2

H.O.

#6-350

#6-2/0

41⁄2

20 5⁄16

16

21⁄2

2

1

U8213-RL

3

H.O.

#6-350

#6-2/0

41⁄2

28 1⁄2

16

21⁄2

2

1

U8214-RL

4

H.O.

#6-350

#6-2/0

41⁄2

40 11⁄16

16

21⁄2

2

1

U8215-RL

5

H.O.

#6-350

#6-2/0

41⁄2

48 7⁄8

16

21⁄2

2

1

U8216-XL

6

C.P.

#6-350

#6-2/0

4 ⁄2

57 ⁄16

16

2 ⁄2

2

1

1

1

1

3
⁄4,1⁄2
⁄4,1⁄2
⁄4,1⁄2
⁄4,1⁄2
⁄4,1⁄2

Notes
• Hub: For proper hub selection refer to the hub suffix chart on the accessory page. A hub opening is supplied at each end
	 and the extra opening is closed with a closing plate as standard.
• Fifth Terminal Kit: For field mounted fifth terminal, order 5T8K2 (6 o’clock position).
• Connectors: Extruded aluminum connectors are tin plated.
• 200 Amp Units: 200 amp per position units available—consult factory.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

17

Multi-Position Meter Mains
125 & 200 Amp | 4 Terminals | Ringless | 120/240 VAC

U5882-X

125–200 amp
multi-position
meter mains

U5884-X

125 Amps per Position | 4 Terminal | Multi-Position Meter Mains | Ringless
Catalog
Number

Amps Positions Service Hub

Connectors CU/AL

Dimensions

Line

D"

W"

H"

Weight
(lbs.)

⁄8” x 16 Stud

51⁄8

26 1⁄2

30

58

⁄8” x 16 Stud

51⁄8

34 5⁄9

30

88

⁄8” x 16 Stud

1

5 ⁄8

42 ⁄5

30

107

⁄8” x 16 Stud

1

5 ⁄8

51 ⁄20

30

128

⁄8” x 16 Stud

51⁄8

59 3⁄10

30

146

U5902-X

125

2

OH/UG

C.P.

3

U5903-X

125

3

OH/UG

C.P.

3

U5904-X

125

4

OH/UG

C.P.

3

U5905-X

125

5

OH/UG

C.P.

3

U5906-X

125

6

OH/UG

C.P.

3

4

1

200 Amp / Position | 4 Terminal | Multi Position Meter Mains | Ringless
Catalog
Number

Amps Positions Service Hub

Connectors CU/AL

Dimensions

Line

D"

W"

H"

Weight
(lbs.)

⁄8” x 16 Stud

51⁄8

26 1⁄2

30

58

⁄8” x 16 Stud

51⁄8

34 5⁄9

30

88

⁄8” x 16 Stud

1

5 ⁄8

42 ⁄5

30

107

⁄8” x 16 Stud

1

5 ⁄8

51 ⁄20

30

128

⁄8” x 16 Stud

51⁄8

59 3⁄10

30

146

U5882-X

200

2

OH/UG

C.P.

3

U5883-X

200

3

OH/UG

C.P.

3

U5884-X

200

4

OH/UG

C.P.

3

U5885-X

200

5

OH/UG

C.P.

3

U5886-X

200

6

OH/UG

C.P.

3

4

1

Notes
• Optional: Factory installed breakers are available—consult factory.
• AIC Rating: All models are rated 22K AIC with Siemens breakers.
• Hub: Units supplied with one (1) closing plate. Order hubs separately, see accesory page.
• Fifth Terminal: For field installed fifth terminal, order K5T.
• Connectors: Socket is supplied with 3/8” - 16 hex head nuts with Belleville washers. For connector lug kits, order as extra
	 from chart on accessories page. Separate lug kits are required for line side only.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

18

Transformer Rated

20 amp
transformer
rated

20 Amps | 6–15 Terminals | 600 VAC

2

2

3

3

1

1

1

1299 7237
7235

1300 7545
7544 5732

2 2 2
3

4

UC7237-RL
20 Amps | Ringless | Plunger Bypass | Overhead/Underground Service
Catalog
Number

Terminals Hub

Meter Form

Connectors
CU

Bypass

Dimensions

Knockouts

D"

W"

H"

1

2

3

5

1

1

4
⁄4

UC1299-RL

6

H.O.

4S

#14 - #10

Plunger

3 ⁄16

8

14

2

1 ⁄2

1 ⁄4

1

UC7235-RL

8

H.O.

5S

#14 - #10

Plunger

35⁄16

8

14

2

11⁄2

11⁄4

1

⁄4

UC7237-RL

13

H.O. 6, 8, 9S & (ALT) 10S

#14 - #10

Plunger

3 ⁄16

8

14

2

1 ⁄2

1 ⁄4

1

⁄4

5

1

1

20 Amps | Ring Type | Overhead/Underground Service
Catalog
Number

Terminals

Hub

Meter Form

Connectors
CU

Bypass

Dimensions

Knockouts

D"

W"

H"

1

2

5

1

1

3
⁄4

UC1300-XL

6

H.O.

4S

#14 - #4 Max Plunger

3 ⁄16

8

14

1 ⁄2

1 ⁄4

1

UC7544-XL

8

H.O.

3S

#14 - #4 Max Plunger

35⁄16

8

14

11⁄2

11⁄4

1

⁄4

UC7545-XL

13

H.O. 6, 8, 9S & (ALT) 10S #14 - #4 Max Plunger

5

3 ⁄16

8

14

1

1 ⁄2

1

1 ⁄4

1

⁄4

UC5732-XL

15

H.O.

3 ⁄16

8

14

1 ⁄2

1 ⁄4

1

⁄4

Special

#14 - #4 Max

None

5

1

1

Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.
• Bypass: Plunger type bypass automatically closes when meter is removed.
• Connectors: Units are supplied with mechanical type connectors (#4 max).

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

19

Transformer Rated

20 amp
transformer
rated

20 Amps | 6–13 Terminals | Test Switch Provision

1

1

UC7449-XL

UC7478-YL

1

UC7532-RL
(shown prewired with
Milbank test switch)

1

1

2

7444
7445
7446
7448
7449
7478
7532

1 Piece Cover | Ringless | Overhead/Underground | with test switch provision*
Catalog
Number

Terminals Hub

Meter Form

Connectors
CU

Bypass

Dimensions

Knockouts

D"

W"

H"

1

1

2

UC7478-RL

6

H.O.

4S

#14 - #4 Max

None

4 ⁄8

12

20

1 ⁄4

1

UC7444-RL

8

H.O.

5S

#14 - #4 Max

None

41⁄8

12

20

11⁄4

1

⁄4, 1⁄2

UC7445-RL

13

H.O. 6, 8, 9 & (ALT) 10S

#14 - #4 Max

None

41⁄8

12

20

11⁄4

1

⁄4, 1⁄2

UC5087-RL

13

H.O. 6, 8, 9 & (ALT) 10S

#14 - #4 Max Plunger 4 ⁄8

12

20

1 ⁄4

1

⁄4, 1⁄2

1

1

⁄4, 1⁄2

1

2 Piece Cover | Ringless | Overhead/Underground | with test switch provision*
Catalog
Number

Terminals Hub

Meter Form

Connectors
CU

Bypass

Dimensions

Knockouts

D"

W"

H"

1

UC7532-RL

6

H.O.

4S

#14 - #4 Max

None

41⁄8

12

20

11⁄4

1

⁄4, 1⁄2

2

UC7448-RL

8

H.O.

5S

#14 - #4 Max

None

41⁄8

12

20

11⁄4

1

⁄4, 1⁄2

UC7449-RL

13

H.O. 6, 8, 9 & (ALT) 10S

#14 - #4 Max

None

41⁄8

12

20

11⁄4

1

⁄4, 1⁄2

Notes
• Hubs: For proper hub selection see the hub suffix chart on the accessory page.
• Prewiring: If standard factory pre-wiring is required, refer to wiring diagrams in the general engineering section of this 	
	 catalog. Determine appropriate diagram and send copy with order. If custom factory prewiring is required, specify on 	
	 order. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be 	
	 sure to provide a copy of your wiring diagram. Catalog number will change to match wiring.
• Connectors: Units are supplied with mechanical type connectors (#4 max).
• *Test Switch Cover: Units on this page are not designed for use with test switch covers. Units are available in 51⁄2" deep
	 shell for test switch cover—contact factory for details. It is also possible to remove the test switch bridge and mount a test 	
	 switch to the back of the enclosure.
• Ring Type Option: 2-piece cover units are available in ring type—contact factory for details.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

20

Test Switches

test
switches

4, 7 & 10 Pole

Switch Blades
Two dimples coined into one
side of the switch blade ensure
positive contact in corrosive, sooty
environments—even after years of
inactivity.
Test Switch Covers
Standard test switch covers are made
from impact resistant clear thermal
plastic which has excellent tracking
and moisture resistant properties. If
covers are required, add suffix -WC
(with cover) to the catalog number
or order separately catalog number
K3388. Black flush mount covers are
also available. Order catalog number
K3388-BLK-FL. 10 pole base only.

Test Switch Base
The base is molded from a high
strength, fiberglass reinforced,
thermoset polyester. This material is
track resistant, flame retardant and has
low water absorption qualities. Bases
are available in 7 pole and 10 pole
sizes.
Switch Jaws
The switch blade jaw clips are
constructed from spring grade copper
alloy. The material and design ensure
excellent contact which prevents
overheating.

Standard Cover

Polarity Barrier
For maximum protection potential
circuits are supplied with permanently
mounted barriers made from high
tensile strength polycarbonate.
Current Carrying Parts
Highly conductive copper and copper
alloy materials are used on all current
carrying parts. This ensures conductivity
and deters corrosion. Spring grades
are used where appropriate. Plating is
available if required. Contact general
offices to special order.

Flush Mount Cover (Black)
Socket shells must be 51⁄8" deep
-ORmust not have test switch bridge
mounted on back
in order to support a cover.

Factory Installed: For cover installed add the suffix -WC or -WCFL to the catalog number of desired test switch.
Field Installed: For field installed cover order kit number K3388 or K3388-BLK-FL.
The Milbank test switch is designed to meet the critical requirements of the electric utility industry. Not only do
they meet EEI, ANSI C12.9, and UL standards but they combine several special features giving the Milbank test
switch increased safety, durability and reliability. One such feature is our unique switch blade contact points
which cut through residue that builds up after years of service. Another distinction is our polarity barrier which is
designed to be flexible as well as offer exceptional insulating qualities. Our test switches are constructed from the
latest materials available using modern fabricating and assembly methods.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

21

Test Switches

test
switches

4, 7 & 10 Pole

3 1/2"

7 1/2"

3 1/2"

9 1/2"

Key

Catalog
Number

4-Pole

P

Potential Switch

TS04-0101

X

P

Pn

X

C+

C

X

C+

Line side current switch with
short circuit assembly

TS04-0104

X

C+

C

X

P

Pn

X

C

Load side current switch
with test jack assembly

N

Neutral bar (no switch)

Pn

Neutral Potentail Switch

X

Unused Position on base

C

C+

C

Catalog
Number

7-Pole

TS07-0105

P

P

Pn

C+

Insulating barrier, isolates
both sides of switch
Custom Pole Arrangements:
The key may be used to diagram
your own pole arrangement. Be
sure to specify base size and
whether all C+ line side, current
switch / shunt circuit assemblies
are to be bussed together. The
catalog numbers shown above
are connected in line-load pairs;
therefore, if bussed is required,
different catalog numbers will
apply.

Catalog
Number

7-Pole on a 10-Pole Base

TS07-0049

P

X

P

X

Pn

X

C+

C

C

C+

TS07-0106

X

P

C+

C

P

C+

C

Pn

X

X

Catalog
Number

10-Pole

TS10-0109

P

P

P

Pn

C+

C

C+

C

C+

C

TS10-0110

P

C+

C

P

C+

C

P

C+

C

Pn

TS10-0111

P

P

P

Pn

C

C+

C

C+

C

C+

TS10-0112

C+

C

C+

C

C+

C

P

P

P

Pn

TS10-0016

P

P

P

Pn

C

C+

C

C+

C

C+

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

22

Test Switch Worksheet

TEST SWITCH
WORKSHEET

customer Name:_________________________________________________________________
Address:________________________________________________________________________
________________________________________________________________________________
Phone / Fax #: __________________________________________________________________

test switch base

Handle Color Key
BK

Black

P

Purple

Y

Yellow

GN

The base is molded from a high strength,
fiberglass reinforced, thermoset polyester.
This material is track-resistant, flame-retardant
and has low water absorption qualities. Bases
are available in two standard sizes following
NEMA mounting classifications.

Green

R

Red

BL

Blue

W

White

BKS

Black Stripe

BR

Brown

GR

Grey

O

Orange

WS

White Stripe

Pole Position Chart
1

2

3

4

5

6

7

8

9

10

Special Features
Feature

1

2

3

4

5

6

7

8

9

10

45° Angle Stops
Ganged Handles (C)
Bussing
Colored Handles
Engineering Information: _________________________________________________________________________
_________________________________________________________________________________________________
_________________________________________________________________________________________________

Key
P

Potential Switch

C+

Line side current switch with
short circuit assembly

C

Load side current switch
with test jack assembly

N

Neutral bar (no switch)

Pn

Neutral Potential Switch

X

Unused Position on base
Insulating barrier - one side
Insulating barrier - two sides

Custom Pole Arrangements: The key may be used to diagram your own
pole arrangement. Be sure to specify base size and whether all C+ line side,
current switch / shunt circuit assemblies are to be bussed together. The
catalog numbers shown above are connected in line-load pairs; therefore, if
bussed is required, different catalog numbers will apply.

Number of Poles

q
	7
q
	10
q
	q Other ____
	4

Test Switch Cover (only available for 10-pole bases)

q Yes | Clear ___ Black ___
	No
q
	

Base Size

q
	10-Pole
q
	7-Pole

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

23

Current Transformer Cabinet

current
transformer
cabinet

Panel Enclosure | Type 3R
Application

• For use as a current transformer cabinet or panel enclosure.
• For outdoor use to provide protection against rain, sleet
	 and snow, or indoor use to protect against dripping water.

Construction
• Enclosure and cover manufactured from 16 or 14 gauge
	 G90U galvanized steel.
• The doors are overlapping with no center post.
• Continuous door hinge with stainless steel 	hinge pins.
• Three point pad-lockable handle.
• Panel mounting studs provided for optional back panels.
• Drip shield top and seam-free sides, front and back.

Finish
• ANSI 61 gray polyester powder coating over phosphatized
	 G90U galvanized steel.

PT Cabinets
Catalog Number

Dimensions

Knockout

D"

W"

H"

PT48L

8

8

271⁄2

21⁄2" - right side

PT48AL

8

12

36

21⁄2" - right side

PT48R

8

8

271⁄2

21⁄2" - left side

PT48AR

8

12

36

21⁄2" - left side

PT48AR*

Current Transformer Cabinets | Panel Enclosure
Catalog
Number

UPC #
(7-84572)

Weight

363010-CT3R

18823

363016-CT3R
363610-CT3R

Dimensions

S7860

Steel Panel Catalog # Wood Panel Catalog #

W"

H"

D"

99

36

30

10

A-36P30

A-36P30W

16181

121.5

36

30

16

A-36P30

A-36P30W

17368

113

36

36

10

A-36P36

A-36P36W

363612-CT3R

16185

118

36

36

12

A-36P36

A-36P36W

363616-CT3R

18819

139

36

36

16

A-36P36

A-36P36W

483616-CT3R

25707

163

48

36

16

A-48P36

A-48P36W

484812-CT3R

16184

210

48

48

12

A-48P48

A-48P48W

606013-CT3R

18252

274

60

60

13

A-60P60

A-60P60W

Notes
• *PT48: PT48L and PT48AL has mounting emboss on the right side to be mounted on left side of CT cabinet. PT48R and 	
	 PT48AR have mounting emboss on left side to be mounted on right side of CT cabinet.
• Wall or Pole Mount: For wall or pole mount CT rack order S7860. This unit accomodates 3 donut style CTs. The 		
	 removable cover makes wiring much easier.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

24

Transformer Cabinets

transformer
cabinets

800 Amps

K4797 (studs)

K4798 (studs)

K4729 (with lugs)

K4722 (with lugs)

CT364811-HC CT Cabinet
and K4722 CT Rack

800 Amps | Transformer Cabinets
Catalog Number

C.T. Racks

CT244811-SC

Dimensions

Front Cover

Cover Type

48

1 Piece

Screw

30

48

1 Piece

Screw

36

48

1 Piece

Screw

11

24

48

1 Piece

Hinge

A, B, G, H

11

30

48

1 Piece

Hinge

A, B, G, H

11

36

48

1 Piece

Hinge

D"

W"

H"

A

11

24

CT304811-SC

A, B, G, H

11

CT364811-SC

A, B, G, H

11

CT244811-HC

A

CT304811-HC
CT364811-HC

CT Cabinet Mounting Racks
Code

Catalog
Number

AIC Rating

Amps

Volts

Type of Service

A

K4797

50K

800

600

1Ø3W or 3Ø3W

1

B

K4798

50K

800

600

3Ø4W

1

G

K4729

50K

800

600

1Ø3W or 3Ø3W

6 lugs: (3) #4-600 or (6) #1-250

H

K4722

50K

800

600

3Ø4W

8 lugs: (3) #4-600 or (6) #1-250

Termination Type
⁄2 - 13 studs on 13⁄4" centers
⁄2 - 13 studs on 13⁄4" centers

Notes
• Enclosure: These units are rated Type 3R, powder coated and constructed of galvanized steel.
• Mounting: 1⁄4 - 20 welded studs for use with CT mounting rack.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

25

Transockets

600 amp
transockets

600 Amps | 6–14 Terminals | Donut or Bar Type CTs

3

2

2

2

2

1
1
2

1

2

1

1

1

1890
1891
3912

2

S1890-XT

3

3

1

1

2
3

2674
2690
3831

S2690-XT

S2690-XT

600 Amps | 600 Volts | With PTs and Donut Type CTs | Ringless
Dimensions

Knockouts

Catalog
Number

Terminals

Hub

Meter
Form

PTs Quantity
& Ratio

CTs Quantity
& Ratio

D"

W"

H"

1

2

S1891-XT

8

(2) C.P.

5S

(2) 4:1

(2) 200/5

1

9 ⁄2

18

24

1

2 ⁄2

1

11

S3912-XT

13

(2) C.P.

6S

(2) 2.5:1

(3) 200/5

1

9 ⁄2

18

24

1

2 ⁄2

1

11

S1890-XT

14

(2) C.P.

6S

(2) 2.5:1

(3) 200/5

91⁄2

18

24

21⁄2

1

11

3
⁄16
⁄16

⁄16

600 Amps | 600 Volts | Bar Type CTs Only | Ringless
Dimensions

Knockouts

Catalog
Number

Terminals

Hub

Meter
Form

CTs Quantity
& Ratio

D"

W"

H"

1

2

3

S3831-XT

6

(2) C.P.

4S

(2) 200/5

111⁄4

18

30

4

31⁄2

1

S2690-XT

8

(2) C.P.

5S

(2) 200/5

11 ⁄4

18

30

4

1

3 ⁄2

1

S2674-XT

13

(2) C.P.

8S

(3) 200/5

11 ⁄4

18

30

4

3 ⁄2

1

1
1

1

Notes
• Hubs: Units are supplied with two closing plates as standard. To order hubs as extra refer to the hub suffix chart on the 	
	 accessory page.
• Prewiring: Units supplied prewired with test switch and transformers in place. Contact factory if wiring diagram is desired.
• Pricing: Contact general office for pricing information.
• Other units available - contact factory for details.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

26

Meter Pedestal

100–200 AMP
meter main
pedestal

100–200 Amps | 4 Terminals | Ringless | 120/240 VAC
2

1

2

1
1

2

1

2

1

1

1

2

GRADE LINE

Grade Line

2
18.00

8980

8436
U8436-O

NU8980-O-KK

4 Terminals | Ringless | Underground Service
Catalog Number

Amps

Hub

Connectors CU/AL
Line

Load
#6-350

Bypass

Dimensions

Knockouts

D"

W"

H"

1

Horn

1

4 ⁄8

9

62

2

2

U8436-O

200

Blank

4/0 (line)
2/0 (neutral)

NU8980-O

200

Blank

#6-350

CB1

None

6

9

79

21⁄2

—

NU8980-O-SF100

100

Blank

#6-350

CB

None

6

9

79

21⁄2

—

NU8980-O-200

200

Blank

#6-350

CB

None

6

9

79

2 ⁄2

—

2

1

⁄4,1⁄2

1

Notes
	Field Installed Circuit Breaker Required. 2 Milbank main breaker.
• Hanging Hook: U8436 is supplied with keyhole hanger for easy mounting to building.
• Extension Unit: For U8436, order extension unit K5800 for 15” burial applications and two K5800 units for 30” burial
	applications.
• Series Wired Main: For series wired main order wire kit K4714 and UQFPH-M type circuit breaker.
• Branch Circuit Breakers: Branch interior accepts most manufacturers’ small frame plug-in type circuit breakers (Milbank,
	 GE, Siemens, Cutler-Hammer, Murray).
• SF: SF in catalog number has small frame plug-in type circuit breaker installed on middle stabs of 4-circuit interior. Only
	 two single pole spaces available.
• Fifth Terminal: For field installed fifth terminal, order catalog number K5T.
• Listing: Listed for free standing or wall mount.

1

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

27

Meter Main w/ Load Center Pedestal

100–200 amp
meter main
w/ load center
pedestal

100–200 Amps | 4 Terminals | Ringless
16.07”

1

1
50”

3

80”

3
1

2 2

27.5”

1

Grade Level

24”

5136
5137
9.875”

4.13”

U5136-O-200S
100-200 Amps | 4 Terminals | Meter Main Pedestal | Ringless
Connectors CU/AL

Knockouts

Catalog Number

Service

Meter
Positions

Bypass

Line

Load

1

U5136-O-100S

UG

Single

Horn

#6-350

CB

2

1

⁄2,3⁄4

1

U5136-O-200S

UG

Single

Horn

#6-350

CB

2

1

3

⁄2, ⁄4

1

U5137-O-200S

UG

Double

Horn

#6-350

CB

2

1

⁄2, ⁄4

1

2

3

Notes
• Parallel to Series Conversion: For field converting from parallel wired to series wired order K5194.
• Fifth Terminal: For field installed fifth terminal, order K5T.
• Stabilizer Foot: For field installed stabilizer foot, order K5415.
• Application: Designed for free standing direct burial.
• Receptacles: Consult factory for installed receptacle assemblies.
• Main Breaker: Milbank UQFP-M-(AMP).
• Ring Type Units: Ring type units available—contact Milbank for details.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

3
⁄4
⁄4
⁄4

28

Surface Mount Power Outlet

surface
mount
power
outlets

Millennium Series | Metered & Unmetered

3

3

2

1

3

3

5000

5100

2

2

U5000-XL-75

1

2

U5100-XL-75

125 Amps | Surface Mount Power Outlets
Dimensions

Knockouts

Metered/
Receptacle
Circuit Breaker
Unmetered Configuration Configuration

Loop Feed
Line

D"

W"

H"

1

2

3

U5000-XL

Unmetered

—

—

(2) 1/0-#12

1

5 ⁄2

1

9 ⁄8

19 ⁄4

2

1

1 ⁄2

11⁄4

U5000-XL-41

Unmetered

A

X

(2) 1/0-#12

51⁄2

91⁄8

191⁄4

2

11⁄2

11⁄4

U5000-XL-55

Unmetered

B

Y

(2) 1/0-#12

51⁄2

91⁄8

191⁄4

2

11⁄2

11⁄4

U5000-XL-75

Unmetered

C

Z

(2) 1/0-#12

1

5 ⁄2

1

9 ⁄8

1

19 ⁄4

2

1

1 ⁄2

11⁄4

U5100-XL

Metered

—

—

#6-250

51⁄2

91⁄8

25

2

11⁄2

11⁄4

U5100-XL-41

Metered

A

X

#6-250

51⁄2

91⁄8

25

2

11⁄2

11⁄4

U5100-XL-55

Metered

B

Y

#6-250

51⁄2

91⁄8

25

2

11⁄2

11⁄4

U5100-XL-75

Metered

C

Z

#6-250

5 ⁄2

9 ⁄8

25

2

1 ⁄2

11⁄4

Catalog Number

Receptacle Configurations
A

(1) TT30R, (1) 5-20R GFI

B

C

(1) 14-50R, (1) 5-20R GFI

(1) 14-50R, (1) TT30R,
(1) 5-20R GFI

1

1

1

1

Notes
• Other Configurations: Additional 	
	 configurations are available—contact 	
	 Milbank for details.
• Metered Units: Metered units are 	
	 ring type.

Circuit Breaker Configurations
X

Y

Z

(1) 30A, 1P, 120V
(1) 20A, 1P, 120V

(1) 50A, 2P, 120/240V
(1) 20A, 1P, 120V

(1) 50A, 2P, 120/240V
(1) 30A, 1P, 120V
(1) 20A, 1P, 120V

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

29

Power Outlet Pedestals

power
outlet
pedestals

Millennium Series | Metered & Unmetered

1

2

2

2

1

2

5200
5220

5300
5320

U5200-XL-75

U5300-O-75

125 Amps | Power Outlet Pedestals
Dimensions

Knockouts

Catalog Number

Double Head
Catalog Number

Receptacle
Configuration

Circuit Breaker
Configuration

D"

W"

H"

1

U5200-XL

U5220-XL

—

—

9

5 ⁄16

1

9 ⁄8

64 ⁄2

11⁄4

U5200-XL-41

U5220-XL-41

A

X

59⁄16

91⁄8

641⁄2

11⁄4

U5200-XL-55

U5220-XL-55

B

Y

59⁄16

91⁄8

641⁄2

11⁄4

U5200-XL-75

U5220-XL-75

C

Z

9

5 ⁄16

1

9 ⁄8

64 ⁄2

11⁄4

U5300-O

U5320-O

—

—

59⁄16

91⁄8

701⁄4

11⁄4

U5300-O-41

U5320-O-41

A

X

59⁄16

91⁄8

701⁄4

11⁄4

U5300-O-55

U5320-O-55

B

Y

59⁄16

91⁄8

701⁄4

11⁄4

U5300-O-75

U5320-O-75

C

Z

5 ⁄16

9 ⁄8

70 ⁄4

11⁄4

Receptacle Configurations
A

B

C

9

1

1

1

1

Notes
• Other Configurations: Additional configurations 	
	 are available—contact Milbank for details.
• Metered Units: Metered units are ring type.

(1) TT30R,
(1) 5-20R GFI

(1) 14-50R,
(1) 5-20R GFI

(1) 14-50R, (1) TT30R,
(1) 5-20R GFI

Circuit Breaker Configurations
X

Y

Z

(1) 30A, 1P, 120V
(1) 20A, 1P, 120V

(1) 50A, 2P, 120/240V
(1) 20A, 1P, 120V

(1) 50A, 2P, 120/240V
(1) 30A, 1P, 120V
(1) 20A, 1P, 120V

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

30

Terminal Box

Terminal
BOX

100–400 Amps | 120/240 Volts

Shown with
optional 3Ø
Lug Kit

2

1

1 3

1

4540
4542

3

1 4

3

4544
4546

1

1
4

U4540-XL

9617

4548
4549

1
3

S9617-O

Terminal Boxes | 1Ø and 3Ø | 120/240 Volts
Catalog
Number

Amps Phase

Volts

Hub

Connectors 1Ø to
CU7AL
3Ø Kit

Dimensions

Knockouts

D"

W"

H"

1

2

U4544-XL

100

1

120/240

C.P.

(6) #12-1/0

K4543

41⁄8

913⁄16

18

2

1

1

U4546-XL

100

3

600

C.P.

(6) #12-1/0

N/A

41⁄8

913⁄16

18

2

1

1

U4540-XL

200

1

120/240

C.P.

(6) #6-350

K4539

41⁄8

1413⁄16

23

2 1⁄2

2 1⁄2

U4542-XL

200

3

600

C.P.

(6) #6-350

N/A

41⁄8

1413⁄16

23

2 1⁄2

2 1⁄2

(3) #6-350 or
(2) #4-600
(3) #6-350 or
(2) #4-600

K4547

5

15 ⁄2

27

3

3

1

N/A

5

15 ⁄2

27

3

3

1

U4548-RXL

400

1

120/240

C.P.

U4549-RXL

400

3

600

C.P.

1
1

3

4

⁄4,1⁄2

—

⁄4,1⁄2

—

11⁄4

1

⁄4,1⁄2

11⁄4

1

⁄4,1⁄2

1

⁄4, ⁄2

1

⁄4

⁄4, ⁄2

1

⁄4

1

Notes
• Hub: Standard hub opening on top with closing plate attached.
• Features: UL-listed pad lockable Type 3R enclosure.
• 3Ø 120/240V Application: Field installable 3Ø lug kit converts 1Ø unit to 3Ø unit.

Secondary Service Pedestal for Underground Use
Catalog Number

Pedestal Supplied With

S9617-O

(3) 6 hole 350 MCM connector bars

Dimensions
D"

W"

H"

10 ⁄32 10 ⁄8 4511⁄16
11

3

Notes
• Features: Unit supplied with 3/8"-16 penta head bolt and pad-lockable latch.
• Stake: Catalog number S9110 must be added to catalog number in order to ensure shipment of 72" stake for free 	
	 standing installation (i.e. S9617-O-S9110).

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

31

Terminal Box

secondary
terminal box

Secondary

8333

2
1

2
1

1

2

1787

1
2

Terminal Boxes
Catalog
Number

Hub

Amps
(End Connection)

S1787-4X

(4) C.P.

S8333-6X

(6) C.P.

Amps (Center Connection)

Dimensions

Knockouts

Each Way

Total

D"

W"

H"

1

950

950

1900

14

30

42

7

9

1500

1500

3000

24

44

52

—

—

⁄8

2
⁄16

Notes
• Hot Bus Support: Hot bus support and support ear available as kit for the S8333. Order kit K1822. Kit also includes 	
	 hardware to mount bus.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

32

Commercial Pedestals

commercial
pedestals

Attractive | Easy to Install | Secure | Cost-Effective

Milbank Commercial Pedestals are pad-mounted,
weatherproof electrical enclosures consisting of
a utility pull section with optional meter socket,
and a customer section containing distribution and
control equipment. Milbank Commercial Pedestals
are an attractive, secure, easy to install and costeffective solution when underground remote
site power distribution and control equipment is
required, replacing unsightly and inefficient strut and
backboard structures.
Strut and backboard

Commercial pedestal

UL-listed as Industrial Control Equipment (File E113855)
Standard Features
• Type 3R rainproof, vandal-resistant cabinet of polyurethane
powder-coated steel (aluminum or stainless steel also available)
• UL-listed as enclosed industrial control equipment (UL508)
• Isolated lockable & sealable utility metering and lug landing
sections
• Lockable customer section for distribution and control equipment
with internal deadfront
• Print pocket inside customer section door contains wiring
schematics and installation instructions
• Most load centers are UL-listed for use with various
manufacturers’ circuit breakers
• All stainless steel external hardware (screws, bolts, hinges,
handles, hasps and sealing screws)

Ringless
socket

Ring type
socket

Utility lug
landing

Customer
interior

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

Commercial Pedestals
Attractive | Easy to Install | Secure | Cost-Effective
Applications
These units are ideal for controlling and metering:
• Traffic signals
• Street lighting
• Irrigation and sprinkler systems
• Cell towers and telephone vaults
• Pump stations
• Temporary power for fairgrounds, swap meets, outdoor markets, 	
	 portable offices, holiday lights, etc.
• Outdoor lighting for athletic fields, tennis and basketball courts, 	
	 parking lots, landscaping and subdivision entrances, etc.

Available Factory-Installed Options
• Meter sockets: ring type or ringless, up to 400 amp
• Main and branch breakers or T fuses
• Distribution: copper load centers and panel boards
• Clocks, timers and relays
• Photoelectric cells and controls
• Power receptacles: pin and sleeve, twist lock or straight blade
• Contactors: definite purpose, electrical or mechanically held, IEC 	
	 and mercury types
• Surge protection and lightning arrestors
• Reserve inlet generator receptacle with interlocked circuit breakers
• Motor starters and relays
• Push button controls
• Thermostat controls, fans and heating strips
• Power blocks and terminal blocks
• Steel, aluminum and plywood backboards
• Transformers
• Interlock devices for circuit breakers
• Available in steel, aluminum (unpainted, painted or anodized) or
	 stainless steel construction with powder-coated finish available in
	 eight standard colors or special-ordered RAL colors
• Available for applications up to 400 amp, 120V, 208V, 240V, 277V, 	
	 480V - 1Ø or 3Ø

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

33

commercial
pedestals

34

Generators

GENERATORS

Home Standby & Portable

With over 85 years in the electrical distribution industry, Milbank is proud to offer quality
home standby and portable generator systems in partnership with Briggs & Stratton and
Pramac.

Home Standby Generators
• 7, 10 & 12 kW vertical air-cooled
• 17 & 20 kW horizontal air-cooled
• 30 & 45 kW horizontal liquid-cooled
• By Briggs & Stratton

Portable Generators
• Briggs & Stratton
• Pramac (includes Powermate & DeWALT)

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

Electric Vehicle Supply Equipment
Milbank | Driving the Future of Power

35

electric
vehicle
supply
equipment

From a wall-mounted single dock unit in a residential garage, to a citywide municipal
integration, our scalable, flexible, reliable solution is designed for effectiveness in virtually any
installation scenario.

Level II Models
MEVSE-RS—Residential, single wall mounted; overnight at-home
charging.
MEVSE-RS Dual—Pedestal mounted with two ports; ideal for multifamily and high-traffic commercial parking lots.
MEVSE-RS+—Available in single, dual and quad configurations with
the addition of programmable, smart charging capabilities; allows
communication with the grid for charging when energy consumption
is low; allows connectivity to GPRS.

Level III Models
DC Fast Charge — Stations feature JARI/TEPCO connectors and
CHAdeMO certification; practical networking and payment options;
available from 30-60kW models suitable for public and fleet usage;
charges in 15-30 minutes.

Suitable EV Station Locations
• Shopping malls
• Theatres
• Municipal buildings
• Central business districts
• Entertainment districts
• Stadiums & arenas
• Rest areas
• Truck stops / travel plazas
• Camping / RV parks
• Restaurants
• Parking garages
• Public curbside parking
• Office buildings
• Single-family residences
• Multi-unit residences
• Airports
• Hotels
• Casinos
• Anywhere people park for extended periods of time

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

36

Accessories

accessories

Disconnect/Out of Service Devices

Disconnect Sleeve
Application

Discretely disconnects service at the meter while
leaving the meter in place.
Mylar® polyester film — flexible, durable and
stable even at extreme temperatures.

Features

Safe, reliable and easy to install
Standard design fits most meter blades
High dielectric strength
Non-hygroscopic

Ordering

M5-144 disconnect sleeves
(above) shown installed on meter
blades (below)

Order M5-144
Turn off main switch or breaker before installation
Remove meter from socket

Installation
Guidelines

Place disconnect sleeve over load side blades
Replace meter and reseal
Do not use disconnect sleeves on lever bypass
sockets.

Plug-In Out Of Service Device
Application

Disconnects service at the meter.
Meter stays in place to prevent tampering and to
simplify power restoration

Features

Rotated meter shows that service has been
disconnected
Easily plugs into all new Milbank 200 amp blocks
with square fifth terminal hole

Ordering

K4974 (above); meter with K4974
installed and service disconnected
(below).

Order K4974

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

37

Accessories

accessories

Hubs and Closing Plates

-RL
Small hub opening

-WL

A7514

-YL

A7515

1 ⁄4" hub

1" hub

-ZL

A7516

-DL

1 ⁄2" hub

1

A7517

2" hub

1

-EL

A7518

2 ⁄2" hub
1

-XL

A7551

Small closing
plate

-R
Large hub opening

-F

A8110
3" hub

-G

A8111

3 ⁄2" hub
1

-H

A8112
4" hub

-X

A9064

Large closing plate

Notes
• Suffix: Add to catalog number for factory installation of hub.
• Packaging: Individually packed units for field installation.
• Abbreviations: H.O. (hub opening), C.P. (closing plate).

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

-RRL

S8324

Large hub opening
adapted to small
hub oepning

38

Accessories

accessories

Connector Kits, Closing Covers & Sealing Rings

Connector Kits | For Use with 3⁄8"-16 Stud Type Units Only

Single

K8180 (sold in pairs)

Twin

Suffix

Part #

(3 per set) - 1Ø

Suffix

Part #

(3 per set) - 1Ø

K1

K1539

6-350

K2

K1350

6-350

K3

K1540 6-350 (non rotating)

K2L

K1350L

6-350 (non rotating)

K3L

K1540L

4-600 or (2) 1/0250
(non rotating)

K4

K1541

4-600

Suffix

Part #

(4 per set) - 3Ø

Suffix

Part #

(4 per set) - 3Ø

K5

K3082

6-350

K6

K3442

6-350

K7

K3441

4-600 or (2) 1/0250

K8

K3083

4-600

Closing Covers

Bypass Link

Generator Interlock

Meter Closing Plate
(Ring Type / Ringless)

Metal Closing Plate
(For Ringless Sockets)

6003 - Grey Plastic

CP-21

K5815 - large QN with small frame Q
K5820 - large frame QN with large frame QN

Allows only one
breaker to be in the
“on” position when
back-feeding with
a standby power
generator.

K5830 - small frame Q to small frame Q

6116 - Clear Plastic

Sealing Rings

MR-2 - Snap Action
MR2-SS - Stainless
Steel

MR-4 - Screw Type
(Stainless Steel)

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

39

Accessories

accessories

Fifth Terminals and Tap Connectors
Fifth Terminals

Triplex Ground

5T8K2 - 100-200 Amp
“Plug-In”

K5T - 200 Amp
(Block with Square Hole)

K3865 - Heavy Duty Jaw
Clamping
(K3866 without Neutral Wire)

Tap Connectors (3 per set)
Replaces the load or
line side slide-in nut
assembly on Milbank
200 amp sockets.
Allows for a 100 amp
tap location in addition
to the #6-350 kcmil
load-side connector.
K5022 includes safety
barrier extensions for
applications over 300
VAC. Three lugs per kit.

Locknut Clearances
Clearance for Locknuts on Knockouts
“D” (“D”

“D”

⁄2

11⁄8

3

⁄4

13⁄8

1

13⁄4

11⁄4

21⁄4

11⁄2

25⁄8

2

31⁄8

1

2 ⁄2

31⁄2

3

41⁄4

31⁄2

43⁄4

4

53⁄8

K4977-EXT - External Hex (set of 3)
K5022-INT - Internal Hex (set of 4 w/ barrier)

Knockout Actual Sizes
Conduit to Knockout Reference Chart
Milbank
Knockout

Actual Size
Milbank Knockout

⁄2

1

⁄2

⁄4

3

⁄4

11⁄8

1

1

13⁄8

11⁄4

11⁄4

13⁄4

11⁄2

11⁄2

2

2

2

21⁄2

21⁄2

21⁄2

3

3

3

35⁄8

31⁄2

31⁄2

41⁄8

4

4

441⁄64

1
3

in nearest practical dimension)

Knockout Size

K4977-INT - Internal Hex (set of 3)

Conduit
Size

K1190
(For factory installed
triplex ground, add
suffix -TG to catalog
number)

⁄8

7

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

1

40

Watthour Meter Forms

watthour
meter
forms

Standard Forms | Transformer Rated or Self-Contained

SC

2 and 3-WIRE FORMS
1S & 2S

SC

2 and 3-WIRE FORMS
1S & 2S with BYPASS

TR

2-WIRE FORM 3S
5th Term. 9 o'clock

TR

2-WIRE FORM 3S
with BYPASS

TR

SC

SC

SC

2-WIRE FORM 3S
with BYPASS

2 ELEMENT
3-WIRE NETWORK
FORM 12S 5th
TERM. 9 o'clock

2 ELEMENT 3-WIRE
NETWORK FORM 12S
with BYPASS
5th Term. 9 o'clock

2 ELEMENT
3-WIRE NETWORK
FORM 12S 5th
TERM. 6 o'clock

TR

TR

SC

3-WIRE FORM 4S

3-WIRE FORM 4S
WITH BYPASS

TR

2 ELEMENT
2∅3W, 2∅4W, 3∅3W
FORM 5S

TR
2 ELEMENT 2∅3W,
2∅4W, 3∅3W
FORM 5S with
BYPASS

2 or 3 ELEMENT
3∅4W Y or ∆
Y FORM 14S
∆ FORM 15S

SC

2 ELEMENT
2∅3W, 2∅4W, 3∅3W
FORM 13S

SC
2 or 3 ELEMENT
3∅4W Y or ∆
FORMS 14S & 15S
with BYPASS

SC

2 or 3 ELEMENT
2∅3W, 2∅4W, 3∅3W
FORM 13S with
BYPASS

TR

2-WIRE FORM 3S
5th Term.6 o'clock

SC
2 ELEMENT 3-WIRE
NETWORK FORM 12S
with BYPASS
5th Term. 6 o'clock

TR
2 ELEMENT
3∅4W Y or ∆
Y FORM 7S
∆ FORM 24S
with BYPASS

TR

2 or 3 ELEMENT
3∅4W Y or ∆
Y FORM 9S
∆ FORM 8S

TR = TRANSFORMER RATED
SC = SELF CONTAINED

TR
2 or 3 ELEMENT
3∅4W Y or ∆
FORMS 8S & 9S
with BYPASS

TR

TR

2 ELEMENT
3∅4W Y
FORM 6S

2 ELEMENT
3∅4W Y
FORM 6S
with BYPASS

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

41

Meter Forms

meter
forms

Reference Information
diagram a

1∅2w with 1 P.T. & 1 C.T.
Single Stator Meter(2W1∅) - Form 3S
5T Socket, Test Switch #TS04-0101

diagram b

1∅3w with 1 C.T.
Single Stator Meter (2W1∅) - Form 3S
5T Socket, Test Switch #TS04-0101
DIAGRAM B

DIAGRAM A

diagram d

1∅3w or 3W Network with 2 C.T.’s
2 Stator Meter - Form 5S
8T Socket, Test Switch #TS07-0105

DIAGRAM C

DIAGRAM D

(ALT.LOC.)

(ALT.LOC.)

+
C1

P1 PN

diagram c

1∅3w with 2 C.T.’s
Single Stator Meter (3W1∅) - Form 4S
6T Socket, Test Switch #TS07-0105

P1 PN

C1

+
C1

C1

+
C1

P1 P2

+
C2

+
C2 C2

+
C1

P1 P2 PN

+
C2 C2

C1

+

P.T. +
+

I
LINE
N

+

LOAD

C.T.

I

+

LINE 2
N

C.T.

+

diagram e

3∅3w “∆” with 2 P.T.’s & 2 C.T.’s
2 Stator Meter - Form 5S
8T Socket, Test Switch #TS07-0105

diagram f

3∅3w “∆” with 2 C.T.’s
2 Stator Meter - Form 5S
8T Socket, Test Switch #TS07-0105

DIAGRAM E

P1 P3

LINE

(BONDED)

(BONDED)

P 2 C+
1

P 2 C+
1

P1 P3

C.T.
C.T. +

LOAD

+

diagram g

LINE

P1

P 3 P N C+

+

PT

C+ C

+
+

+
C.T.

+

LOAD

+
C.T.

C.T.

+

+
C

C

P3 PN

PT

+ C
C

P1 P2 P3 PN

+ C
C

PT

C.T.

C.T.

+
+

C.T.

(BONDED)

+
+

LOAD
C.T.

C

C+

C

C+

+
+

C.T.

+
+

LOAD
C.T.

C+

C

C+

C

1
2
LINE
3
N(BONDED)

+

+
+

C.T.

+
+

C.T.

+
+

Prewiring: If standard factory prewiring is required,
refer to wiring diagrams on this page. Determine
appropriate diagram and send a copy with order.
If custom factory prewiring is required, specify on
order. Be sure to include meter socket catalog
number, test switch make and catalog number,
meter form number and provide a copy of your
wiring diagram.

C+ C

PT

PT

+

+
1
2
LINE
3
N(BONDED)

+
+

C.T.

+
+

C.T.

+

LOAD

+

C.T.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

C

+
PT

diagram j

+ +
+ +

+

+

+

C+

DIAGRAM J

+

1
2
LINE
3
N(BONDED)

1
2
LINE
3
N

LOAD

+

3∅4w “Y” with 3 P.T.’s & 3 C.T.’s
3 Stator Meter - Form 9S
13T Socket, Test Switch #TS10-0109

DIAGRAM I

P1 P2 P3 PN

LOAD

+
C.T.

diagram i

3∅4w “Y” or “∆” with 3 C.T.’s
“Y” 3 Stator Meter - Form 9S
“∆” 2 Stator Meter - Form 8S
13T Socket, Test Switch #TS10-0109

+

+

1
LINE 2
3

+

C.T.

diagram h

P1

+

1
LINE 2
3

C.T.

3∅4w “Y” with 2 P.T.’s & 3 C.T.’s
2 1⁄2 Stator Meter - Form 6S
13T Socket, Test Switch #TS10-0109

+
PT

+

DIAGRAM H

C+ C

C

+

I
N(BONDED)
2

DIAGRAM G

+
C3 C3

C1

+

3∅4w “Y” with 3 C.T.’s
2 1⁄2 Stator Meter - Form 6S
13T Socket, Test Switch #TS10-0109

DIAGRAM F

+
C3 C3

C1

+

I
N(BONDED)
2

LOAD

LOAD
C.T.

42

Materials & Finishes

materials
& finishes

Reference Information

Materials
Steel Quality
The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing.
*American Iron and Steel Institute.

Steel Sheet
16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. (AISI G90)
14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.

Aluminum Extrusion
Wire-Terminals: Alloy; 6061-T6, Tin-plated for Cu/Al wire.
Bus Bar: Alloy; 6101-O & 6063-O

Aluminum Sheet
3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064–.125

Copper Sheet & Bus
Electrolytic copper with tin plating in most applications.

Insulating Materials
• 	In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant,
thermoset polyester molding compounds.
• 	Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds.
• 	Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component
parts and barriers.

Finish
Process
Light gray state-of-the-art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the
chemical analysis of the weather resistant finish, please contact the factory.

Metal Fastners
Zinc-coated with a chromate dip.

Ratings & Compliance
Ratings & Compliance
All Milbank electrical enclosures in this catalog are rated “Type 3R Enclosure” unless specified otherwise on the product’s page. All
enclosures with a UL designation are constructed per the appropriate UL Standard and may be installed per the National Electric Code.
UL procedure files associated with the UL Standards are listed as follows: Meter Sockets (UL 414, File E30202), Test Switches (UL 414, File
E62531), Power Outlets (UL 231, File E90945), Panelboards (UL 67, File E32628) and Pullout Switches (UL 1429, File E133062). Additional
standards are utilized as applicable: Meter Sockets (ANSI C12.7), Test Switches (ANSI C12.9) and Panelboards (NEMA PB-1).

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

Product Specifications
Reference Information

43

PRODUCT
SPECIFICATIONS

Enclosure Information
Milbank Electrical Meter Enclosures Specification Note
All Milbank electrical enclosures in this catalog are rated “Type 3R Electrical Enclosure” unless specified otherwise. All enclosures with a
UL designation are constructed per the appropriate UL standard and may be installed per the National Electric Code. Meter sockets are
constructed per “UL 414, Meter Sockets”, file #E30202 and per “ANSI C12.7-1993-Meter Sockets”. All test switches are constructed per “UL
414, Meter Sockets”, file #E30302 and per “ANSI C12.9-1993-Test Switches”. Power outlets are constructed per “UL 231, Power Outlets”,
file #E90945. Panelboards are constructed per “UL 67, Panelboards”, file #E32628 and “NEMA PB-1-1984-Panelboards”. Pullout switches
are constructed per “UL 1429, Pullout Switches”, file #133062.

Definitions Pertaining to Nonhazardous Locations | Indoor Use
Type 1 Enclosure
Type 1 enclosures are intended for indoor use primarily to provide a degree of protection against limited amounts of falling dirt.

Type 12 Enclosure
Type 12 enclosures are intended for indoor use primarily to provide a degree of protection against circulating dust, falling dirt and dripping
noncorrosive liquids.

Type 13 Enclosure
Type 13 enclosures are intended for indoor use primarily to provide a degree of protection against dust, spraying of water, oil and
noncorrosive coolant.

Definitions Pertaining to Nonhazardous Locations | Outdoor Use
Type 3 Enclosure
Type 3 enclosures are intended for outdoor use primarily to provide a degree of protection against rain, sleet, windblown dust and damage
from external ice formation.

Type 3R Enclosure
Type 3R enclosures are intended for outdoor use primarily to provide a degree of protection against rain, sleet and damage from external
ice formation.

Type 4 Enclosure
Type 4 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain,
splashing water, hose-directed water and damage from external ice formation.

Type 4X Enclosure
Type 4X enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust
and rain, splashing water, hose-directed water and damage from external ice formation.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

44

Index

INDEX

6003....................................................38
6116....................................................38
363010-CT3R.......................................22
363016-CT3R.......................................22
363610-CT3R.......................................22
363612-CT3R.......................................22
363616-CT3R.......................................22
483616-CT3R.......................................22
484812-CT3R.......................................22
5T8K2..................................................39
606013-CT3R.......................................22
A7514..................................................37
A7515..................................................37
A7516..................................................37
A7517..................................................37
A7518..................................................37
A7551..................................................37
A8110..................................................37
A8111..................................................37
A8112..................................................37
A9064..................................................37
AP2300-03.............................................4
AP2300-03-5T........................................4
AP2300-03-5T-AB..................................4
AP2300-03-6T........................................4
AP2300-04.............................................4
AP2300-07.............................................4
AP2300-08.............................................4
CP-21...................................................38
CT244811-HC......................................24
CT244811-SC......................................24
CT304811-HC......................................24
CT304811-SC......................................24
CT364811-HC......................................24
CT364811-SC......................................24
K1190..................................................39
K1350..................................................38
K1350L................................................38
K1539..................................................38
K1540..................................................38
K1540L................................................38
K1541..................................................38
K3082..................................................38
K3083..................................................38
K3441..................................................38
K3442..................................................38
K3865..................................................39
K3866..................................................39

K4722..................................................24
K4729..................................................24
K4797..................................................24
K4798..................................................24
K4974..................................................36
K4977-EXT...........................................39
K4977-INT...........................................39
K5022-INT...........................................39
K5815..................................................38
K5820..................................................38
K5830..................................................38
K5T......................................................39
K8180..................................................38
M5-144................................................36
MR-2....................................................38
MR2-SS................................................38
MR-4....................................................38
NU8980-O...........................................26
NU8980-O-2002..................................26
NU8980-O-SF100................................26
PT48AL................................................22
PT48AR................................................22
PT48L...................................................22
PT48R..................................................22
S1787-4X.............................................31
S1890-XT.............................................25
S1891-XT.............................................25
S1910-YL...............................................8
S2417-DL...............................................8
S2417-RL...............................................8
S2674-XT.............................................25
S2690-XT.............................................25
S3831-XT.............................................25
S3912-XT.............................................25
S4275-DL...............................................8
S4339-RL...............................................8
S8324..................................................37
S8333-6X.............................................31
TS04-0101...........................................21
TS04-0104...........................................21
TS07-0049...........................................21
TS07-0105...........................................21
TS07-0106...........................................21
TS10-0016...........................................21
TS10-0109...........................................21
TS10-0110...........................................21
TS10-0111...........................................21
TS10-0112...........................................21

U1797-O-K2L-K3L...............................11
U3328-RXL.............................................8
U4363-R...............................................11
U4505-X...............................................11
U4540-XL.............................................30
U4542-XL.............................................30
U4544-XL.............................................30
U4546-XL.............................................30
U4548-RXL...........................................30
U4549-RXL...........................................30
U5000-XL.............................................28
U5000-XL-41........................................28
U5000-XL-55........................................28
U5000-XL-75........................................28
U5100-XL.............................................28
U5100-XL-41........................................28
U5100-XL-55........................................28
U5100-XL-75........................................28
U5136-O-100S.....................................27
U5136-O-200S.....................................27
U5137-O-200S.....................................27
U5168-XTL-100....................................13
U5168-XTL-200....................................13
U5169-XTL-100....................................13
U5169-XTL-200....................................13
U5200-XL.............................................29
U5200-XL-41........................................29
U5200-XL-55........................................29
U5200-XL-75........................................29
U5220-XL.............................................29
U5220-XL-41........................................29
U5220-XL-55........................................29
U5220-XL-75........................................29
U5300-O..............................................29
U5300-O-41.........................................29
U5300-O-55.........................................29
U5300-O-75.........................................29
U5320-O..............................................29
U5320-O-41.........................................29
U5320-O-55.........................................29
U5320-O-75.........................................29
U5764-X-200-CB.................................15
U5765-X-200-CB.................................15
U5767-X-200-CB.................................15
U5784-O-200-CB.................................15
U5787-O-200-CB.................................15
U5796-X-400-CB.................................15
U5797-O-400-CB.................................15

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

45

Index
U5799-O-400-CB.................................15
U5842-PXL-200....................................12
U5842-RL.............................................12
U5842-RL-100......................................12
U5844-PXL-200....................................12
U5852-RL.............................................12
U5852-RL-100......................................12
U5852-RL-200......................................12
U5854-RL-200......................................12
U5882-X...............................................17
U5883-X...............................................17
U5884-X...............................................17
U5885-X...............................................17
U5886-X...............................................17
U5890-X-2/200....................................14
U5891-X-2/200....................................14
U5892-X-2/200....................................14
U5893-X-2/200....................................14
U5894-X-2/200....................................14
U5895-X-2/200....................................14
U5902-X...............................................17
U5903-X...............................................17
U5904-X...............................................17
U5905-X...............................................17
U5906-X...............................................17

INDEX

U5929-XL...............................................5
U5934-XL...............................................5
U7017-DL-TG........................................7
U7017-RL-TG.........................................7
U7017-RL-TG-5T....................................7
U7018-XL-TG.........................................7
U7021-DL-TG........................................6
U7021-RL-TG.........................................6
U7021-RL-TG-5T....................................6
U7040-RL-TG.........................................6
U7420-RL...............................................9
U7421-RL...............................................9
U7422-RXL.............................................9
U7423-RXL.............................................9
U7487-RL-TG.........................................5
U7487-RL-TG-5T....................................5
U7490-YL-TG.........................................5
U7490-YL-TG-5T....................................5
U8212-RL.............................................16
U8213-RL.............................................16
U8214-RL.............................................16
U8215-RL.............................................16
U8216-XL.............................................16
U8436-O..............................................26
U9700-RRL.............................................9

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

U9701-RXL.............................................9
UAP5024-XL........................................13
UC1299-RL..........................................18
UC1300-XL..........................................18
UC5087-RL..........................................19
UC5732-XL..........................................18
UC7235-RL..........................................18
UC7237-RL..........................................18
UC7444-RL..........................................19
UC7445-RL..........................................19
UC7448-RL..........................................19
UC7449-RL..........................................19
UC7478-RL..........................................19
UC7532-RL..........................................19
UC7544-XL..........................................18
UC7545-XL..........................................18
UCSS3433-O.......................................10
UCSS3436-O.......................................10
UCSS3438-O.......................................10
USS3914-O..........................................10
USS4701-O..........................................10
USS4801-O..........................................10
USS4801-O-5T9...................................10

46
NOTES

Notes

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

Notes

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 816.483.5314 | milbankworks.com

47
NOTES

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

INTERNATIONAL 3/13



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c003 61.141987, 2011/02/22-12:03:51
Create Date                     : 2013:03:07 11:39:29-06:00
Metadata Date                   : 2013:03:07 11:40:12-06:00
Modify Date                     : 2013:03:07 11:40:12-06:00
Creator Tool                    : Adobe InDesign CS5.5 (7.5.3)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 11987 bytes, use -b option to extract), (Binary data 12328 bytes, use -b option to extract)
Instance ID                     : uuid:d59ff264-593d-4562-a482-c15ba77ebdb3
Document ID                     : xmp.did:A93F24564887E211B28AFD796347B020
Original Document ID            : xmp.did:860755593A03E2118F05AE0EA9CB0C4F
Rendition Class                 : proof:pdf
History Action                  : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:860755593A03E2118F05AE0EA9CB0C4F, xmp.iid:677232354E03E2118F05AE0EA9CB0C4F, xmp.iid:687232354E03E2118F05AE0EA9CB0C4F, xmp.iid:DC7316BD5E03E2118F05AE0EA9CB0C4F, xmp.iid:8F0DCF7B6303E2118F05AE0EA9CB0C4F, xmp.iid:5EE8AAE06303E2118F05AE0EA9CB0C4F, xmp.iid:FD8D203AC10CE211AEF9BAB4534B811F, xmp.iid:DF47A5A9803DE2119B5DC3934B1D7A59, xmp.iid:CADA01D6803DE2119B5DC3934B1D7A59, xmp.iid:5C52ACFA803DE2119B5DC3934B1D7A59, xmp.iid:5D52ACFA803DE2119B5DC3934B1D7A59, xmp.iid:5E52ACFA803DE2119B5DC3934B1D7A59, xmp.iid:CA75A2DB893DE2119B5DC3934B1D7A59, xmp.iid:71BB60E9913DE2119B5DC3934B1D7A59, xmp.iid:C0C7FEB39D3DE2119B5DC3934B1D7A59, xmp.iid:DE804162483EE21183FED970A5775A11, xmp.iid:A7AD5C015A3EE21183FED970A5775A11, xmp.iid:389246545F3EE21183FED970A5775A11, xmp.iid:65A03922653EE21183FED970A5775A11, xmp.iid:BC64D3B2F43EE211A49EEA6996BB8DDB, xmp.iid:607DE0FF063FE211A49EEA6996BB8DDB, xmp.iid:4F2BB089263FE211A49EEA6996BB8DDB, xmp.iid:7274E837E43FE2118243A99CFB1ED936, xmp.iid:F4C48A05EF3FE2118243A99CFB1ED936, xmp.iid:BA9D9E7EB240E211A44FC2AD6B24517F, xmp.iid:9CADA429B540E211A44FC2AD6B24517F, xmp.iid:0B3C1C6CB540E211A44FC2AD6B24517F, xmp.iid:0C3C1C6CB540E211A44FC2AD6B24517F, xmp.iid:0D3C1C6CB540E211A44FC2AD6B24517F, xmp.iid:7DD41120C240E211A44FC2AD6B24517F, xmp.iid:2F051230D842E211B1A8F76443300450, xmp.iid:EBA3B1491943E211B1A8F76443300450, xmp.iid:4DC94E379E48E211B655F15BD78A7B44, xmp.iid:0E62873F7B50E211B9B18F4256B72475, xmp.iid:3AC3CD203255E211B716DC9A9613B5EF, xmp.iid:3052414BFA55E211B314F75A6C4D7FF6, xmp.iid:D3F918282159E21199669445F84656A2, xmp.iid:34E0C900EE59E2119B8DEA0E871A1028, xmp.iid:12CDB14B1C76E2119C6E995C71A90413, xmp.iid:7C47012D1F76E2119C6E995C71A90413, xmp.iid:059316553A87E211B28AFD796347B020, xmp.iid:8C39D6553A87E211B28AFD796347B020, xmp.iid:28C419504287E211B28AFD796347B020, xmp.iid:173E911A4887E211B28AFD796347B020, xmp.iid:183E911A4887E211B28AFD796347B020, xmp.iid:A93F24564887E211B28AFD796347B020, xmp.iid:DE096B2C4C87E211B28AFD796347B020, xmp.iid:DF096B2C4C87E211B28AFD796347B020
History When                    : 2012:09:20 10:46:31-05:00, 2012:09:20 13:08:40-05:00, 2012:09:20 13:08:40-05:00, 2012:09:20 15:07-05:00, 2012:09:20 15:40:58-05:00, 2012:09:20 15:43:48-05:00, 2012:10:02 13:44:41-05:00, 2012:12:03 13:35:58-06:00, 2012:12:03 13:37:13-06:00, 2012:12:03 13:38:14-06:00, 2012:12:03 13:39:36-06:00, 2012:12:03 13:39:36-06:00, 2012:12:03 14:41:47-06:00, 2012:12:03 15:39:26-06:00, 2012:12:03 17:03:51-06:00, 2012:12:04 13:25:38-06:00, 2012:12:04 15:31:46-06:00, 2012:12:04 16:09:53-06:00, 2012:12:04 16:51:26-06:00, 2012:12:05 09:59:06-06:00, 2012:12:05 12:10:07-06:00, 2012:12:05 15:55:52-06:00, 2012:12:06 14:33:39-06:00, 2012:12:06 15:50:59-06:00, 2012:12:07 15:10:14-06:00, 2012:12:07 15:29:20-06:00, 2012:12:07 15:31:12-06:00, 2012:12:07 16:21:48-06:00, 2012:12:07 16:53:41-06:00, 2012:12:07 17:02:08-06:00, 2012:12:10 08:45:06-06:00, 2012:12:10 17:27:01-06:00, 2012:12:17 17:05:14-06:00, 2012:12:27 17:15:05-06:00, 2013:01:02 17:14:16-06:00, 2013:01:03 17:07:06-06:00, 2013:01:07 17:22:51-06:00, 2013:01:08 17:49:12-06:00, 2013:02:13 14:31:07-06:00, 2013:02:13 14:51:44-06:00, 2013:03:07 09:18:57-06:00, 2013:03:07 09:18:59-06:00, 2013:03:07 10:16:05-06:00, 2013:03:07 10:57:32-06:00, 2013:03:07 10:59:11-06:00, 2013:03:07 10:59:12-06:00, 2013:03:07 11:26:40-06:00, 2013:03:07 11:36:13-06:00
History Software Agent          : Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5
History Changed                 : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata
Derived From Instance ID        : xmp.iid:183E911A4887E211B28AFD796347B020
Derived From Document ID        : xmp.did:8C39D6553A87E211B28AFD796347B020
Derived From Original Document ID: xmp.did:860755593A03E2118F05AE0EA9CB0C4F
Derived From Rendition Class    : default
Doc Change Count                : 16128
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Page Count                      : 48
Creator                         : Adobe InDesign CS5.5 (7.5.3)
EXIF Metadata provided by EXIF.tools

Navigation menu