661870 Catalog
185820-Brochure 185820-Brochure 185820-Brochure 768386 Batch5 unilog cesco-content
2014-07-05
: Pdf 661870-Catalog 661870-Catalog 768386 Batch5 unilog
Open the PDF directly: View PDF
.
Page Count: 195
| Download | |
| Open PDF In Browser | View PDF |
Table of Contents
Fluorescent Electromagnetic Ballasts
Section 1- Page
Product Overview............................................................................................................................................1-2
Application Operation Information.................................................................................................................1-4
Typical Specifications......................................................................................................................................1-8
Lead Lengths....................................................................................................................................................1-9
T8 (265 mA)..................................................................................................................................................1-10
T12..................................................................................................................................................................1-11
T12 High Output............................................................................................................................................1-13
T12 Very High Output...................................................................................................................................1-17
Circline...........................................................................................................................................................1-18
T12 Slimline..................................................................................................................................................1-19
Preheat and Trigger Start . ............................................................................................................................1-21
Export ............................................................................................................................................................1-25
Dimming .......................................................................................................................................................1-29
Export ............................................................................................................................................................1-30
Fluorescent Electronic Ballasts
Section 2- Page
Product Overview............................................................................................................................................2-2
Application Operation Information.................................................................................................................2-4
Typical Specifications......................................................................................................................................2-7
F17T8.............................................................................................................................................................2-14
F25T8.............................................................................................................................................................2-16
F32T8 (32, 30, 25 & 28 Watt Four Foot Lamps)........................................................................................2-19
F40T8.............................................................................................................................................................2-31
F96T8 Slimline..............................................................................................................................................2-33
F96T8HO High Output.................................................................................................................................2-34
T5....................................................................................................................................................................2-35
T5HO..............................................................................................................................................................2-37
T12 ................................................................................................................................................................2-39
T12 Slimline...................................................................................................................................................2-41
T12HO High Output......................................................................................................................................2-43
T2....................................................................................................................................................................2-44
Energy Management Systems
Section 3- Page
--DCL With DEMANDflex
Product Overview............................................................................................................................................3-2
DemandFlex T8...............................................................................................................................................3-3
DemandFlex T5, T5HO & TT5......................................................................................................................3-6
DemandFlex T8 Wiring Diagram...................................................................................................................3-7
FOR MORE INFORMATION CALL
i
1-800-BALLAST
(225-5278)
Table of Contents
Controllable Lighting
Section 3- Page
--Fluorescent Energy Management/Dimming Ballasts and Controls
Product Overview..........................................................................................................................................3-10
Ballastar® Light Level Switching................................................................................................................3-10
SuperDim® Analog Dimming......................................................................................................................3-11
DaliPro™ Digital Dimming..........................................................................................................................3-13
Application Operation Information...............................................................................................................3-14
Controls for Analog Dimming Ballasts........................................................................................................3-15
DaliPro®........................................................................................................................................................3-16
SuperDim®....................................................................................................................................................3-17
Ballastar® 0-10 Volt......................................................................................................................................3-18
Ballastar® Light Level Switching................................................................................................................3-19
Table of Contents
Compact Fluorescent Ballasts
Section 4- Page
Product Overview............................................................................................................................................4-2
Understanding Compact Fluorescent Technology.........................................................................................4-3
Configurations..................................................................................................................................................4-4
Lamp Matrix....................................................................................................................................................4-5
Typical Specifications......................................................................................................................................4-6
Nomenclature...................................................................................................................................................4-7
5-13 Watt Twin, Quad and Triple...................................................................................................................4-8
18 Watt Twin, Quad and Multiple................................................................................................................4-10
26-28 Watt Quad and Triple........................................................................................................................4-11
32 to 70 Watt Triple and Multiple................................................................................................................4-12
2D and T5 Circular........................................................................................................................................4-14
Long Twin T5................................................................................................................................................4-18
High Intensity Discharge (HID) Ballasts
Section 5- Page
Product Overview............................................................................................................................................5-3
Oil Filled Capacitors........................................................................................................................................5-5
Dry Capacitors.................................................................................................................................................5-7
Bracket Reference Chart..................................................................................................................................5-9
Application and Operation Information........................................................................................................5-10
Nomenclature.................................................................................................................................................5-13
Typical Specifications....................................................................................................................................5-14
Distributor Replacement Kits........................................................................................................................5-15
Core and Coil
Metal Halide ........................................................................................................................................5-19
Pulse Start Metal Halide......................................................................................................................5-23
High Pressure Sodium..........................................................................................................................5-30
50 Hz Core and Coil Ballasts........................................................................................................................5-34
F-Can Ballast..................................................................................................................................................5-36
Potted Core and Coil......................................................................................................................................5-39
Indoor Encased...............................................................................................................................................5-40
Ignitors............................................................................................................................................................5-41
Reference Drawings.............................................................................................................................5-43
Table of Contents
Electronic High Intensity Discharge (eHID) Ballasts
Section 6- Page
Product Overview............................................................................................................................................6-2
Product Family Chart.......................................................................................................................................6-3
Wiring Diagrams..............................................................................................................................................6-4
Dimensions.......................................................................................................................................................6-5
Application and Operation Information..........................................................................................................6-7
Sign Ballasts
Section 7- Page
Application and Operation Information..........................................................................................................7-2
Sign Ballast Footage Chart & Lead Lengths..................................................................................................7-3
Standard............................................................................................................................................................7-4
Max-3 Series....................................................................................................................................................7-5
SIGNA Electronic Sign Ballasts.....................................................................................................................7-6
FOR MORE INFORMATION CALL
ii
1-800-BALLAST
(225-5278)
Table of Contents
Glossary
Section 8- Page
..........................................................................................................................................................................7-1
Obsolete Cross Reference
Section 9- Page
..........................................................................................................................................................................8-1
Index
Section 10- Page
..........................................................................................................................................................................9-1
Warranty
Section 11- Page
........................................................................................................................................................................10-1
Table of Contents
FOR MORE INFORMATION CALL
iii
1-800-BALLAST
(225-5278)
Electromagnetic
Fluorescent Ballasts
A Wide Product Line
To Meet All Your Needs
Our comprehensive line of magnetic ballasts offer outstanding
performance and value. These energy-efficient ballasts carry
the trusted UNIVERSAL® brand and are available for a wide
variety of applications.
Universal Lighting Technologies’ (“Universal”) full spectrum of
solutions includes ballasts for T12/T10/T8 applications, plus
Slimline, Circline, trigger-start and preheat ballasts. We also
make rugged weatherproof ballasts ... and models specifically
engineered for the fast growing export market.
Universal Lighting Technologies is a subsidiary of
Panasonic Electric Works Co., Ltd., a member of the Panasonic Group
Fluorescent-Electromagnetic
Our comprehensive line of energy-efficient magnetic ballasts carry the
trusted UNIVERSAL® brand name.
Product Overview
Rapid Start Ballasts
These ballasts provide smooth starting to Rapid Start lamps —
reaching full brightness in about two seconds without the use of
starters. They have built-in filament windings that energize the lowvoltage cathodes in Rapid Start lamps. Because electrodes are continuously heated, less voltage is required to strike an arc through a
Rapid Start lamp than a Slimline one.
Ballasts for T12/T10 Applications
Universal offers a wide variety of T12 and T10 ballasts to operate
1 - 3 Rapid Start lamps. This lamp/ballast system provides smooth,
virtually instant starting without the use of starters (30- and 40-watt
T12 models and 40-watt T10 models are available). Models for
U-lamp applications are also available. UNIVERSAL® PLUS models
are available for use where maximum efficiency is required. These
“hybrid” type ballasts in corporate an electronic switch which disconnects power to the lamp cathodes after
start-up, saving additional energy.
Ballasts for T8 Applications
Universal’s T8 product offering includes models for F17, F25,
F32 and F40 type T8 lamps. This product line features our OcTek™
electromagnetic ballast models. These models are low initial cost
energy efficient options for use with F32T8,
4 foot Rapid Start lamps. These models are available in several
variations, including full, medium, low light output and hybrid
versions (OcTek™ Plus). These models maximize energy savings
and provide effective choices when retrofitting 4-foot T12 fixtures.
T12/T10 Applications
T8 Applications
Slimline Ballasts
Fluorescent-Electromagnetic
Slimline Ballasts
Our Slimline models are designed for use with single-pin Slimline
lamps. They do not require the use of starters. These ballasts
deliver a high starting voltage to the lamps, enabling an arc to strike
through the tube without preheating the lamp cathodes (which are
specially constructed to withstand the shock).
Rapid Start Ballasts
PAGE 1-2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Product Overview
Circline Ballasts
These products are available in 430 mA Rapid Start and preheat
types, designed for use with Circline lamps. The operating
characteristics are the same for both Circline and conventional
lamps. All Circline socket wires are fully sleeved.
Trigger-Start Ballasts
These ballasts are designed for use with general fluorescent
lamps and do not require the use of starters. They contain
preheat windings which allow regular lamp filaments to be
heated in one second. However, they require a higher
open-circuit voltage than Rapid Start ballasts.
Preheat Ballasts
These units are designed for use with general fluorescent lamps
and require the use of starters. These ballasts deliver an opencircuit voltage high enough to activate the starter to preheat lamp
filaments to a temperature approximately 1750° F. After a few
seconds, the starter opens the filament circuit. This provides an
additional power surge to enable an electric arc to strike through
the lamp and ignite it. Lamp current is then limited by the ballast
to an operating level proper for the lamp.
Preheat Ballast
Export (50/60 Hz) Ballasts
Our export product offering consists of a variety of one- and twolamp models for Rapid Start, Preheat, High Output, Slimline, and
1500 mA lamps. Included in this product line are ballasts for 50
and 60 Hz applications, including 120, 127 and 220 volts. Many of
these models are available with resetting thermal protection.
Export (50/60 HZ) Ballast
Fluorescent-Electromagnetic
PAGE 1-3
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
SAFETY
Subjecting a ballast to excessive voltage for an extended period
of time results in the deterioration of the insulation. This insulation breakdown will cause early ballast failure. Low voltage
has no damaging effect on the ballast. However, lamps may not
start reliably, and early lamp failure could result.
NEC & UL Requirements
Ballast installation presents the possibility of exposure to
potentially hazardous voltages and should be performed
only by qualified personnel. All installation, inspection and
maintenance should be performed only with power to the
fixture turned off. Additionally, all fixtures and ballasts must
be installed and operated in compliance with the National
Electrical Code, Underwriters Laboratories Inc. (UL) requirements and all applicable codes and regulations.
Internal Ballast Protection
Class P Classification - Since January 1, 1984, the National
Electrical Code requires that “where Fluorescent fixtures are
installed indoors, the ballast shall have thermal protection
integral within the ballast except for simple reactance ballasts.” This ruling applies to replacement ballasts as well as to
those contained within new light fixtures.
In compliance with the National Electrical Code, UL has
established a Class P ballast classification for fluorescent light
fixtures indoors.
A Class P ballast must employ internal thermal protection limiting its operating temperature.
Universal UL-approved Class P ballasts comply with the
National Electrical Code requirement and are equipped with an
automatic resetting thermal protector, built-in and adjacent to
the transformer coils. The resetting thermal protector functions as a thermostat which will open and temporarily deactivate the ballast when it exceeds the permissible temperature.
It will reset when the ballast cools to a safe operating temperature. The ballast will continue to cycle until the cause of
overheating is eliminated. If the ballast is defective, it must be
replaced. If the cause is external, a Class P ballast will resume
normal operation after abnormal conditions are eliminated.
Polarity
Polarity refers to the proper connection of ballast lead wires
to line wires. To aid you in making a correct installation,
Universal ballast leads are color-coded for easy identification. The WHITE ballast lead is to be connected to the neutral
(grounded) and the BLACK (or black with white tracer) lead
always to the phase (“hot”) line wire. Systems where neither
of the line wires are at ground potential require specially
designed ballasts. A change in polarity may result in the voltage from the lead to the ground exceeding UL-specified limits.
In some types of ballasts, a change in polarity may decrease
voltage from the lead to the ground, thereby impeding the
starting dependability of the ballast.
Fluorescent-Electromagnetic
Grounding
Ballast cases and fixtures must always be grounded. The
ballast case may be grounded to the fixture or otherwise
grounded. It could be hazardous to make contact with an
ungrounded fixture or ballast when in operation. Neglecting
to properly ground the ballast and fixture combination may
also result in failure of certain lamps to start or for unacceptable levels of electromagnetic noise to be conducted onto the
power lines.
Fusing
Class P ballasts do not require fusing. Fusing can be used
when a single circuit has a large number of fixtures/ballasts.
For a comprehensive list of appropriate fuses, contact our
Technical Engineering Services (TES) Department at
1-800-BALLAST or check out our TES home page at www.
unvlt.com
Operating Line Voltage Limits
To receive the full benefits of rated lamp output and to prolong ballast life, it is essential that voltage supplied to an
installation be maintained within limits prescribed for each
circuit. These limits are listed below:
Nominal Voltage
120
220
240
277
347
480
600
VOLTAGE RANGE
Minimum
Maximum
110
205
220
255
315
450
570
PAGE 1-4
125
232
250
290
364
505
630
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
PERFORMANCE
Lamp Connections
Electromagnetic fluorescent ballasts are designed to generate
voltages in excess of 300 volts. It is imperative that proper
connection to good quality sockets be assured in accordance
with wiring diagrams on each page of the catalog and on
product labels. Some applications may not require the use of
all of the ballasts output leads. If any leads are not to be connected, each should be individually capped and insulated to at
least 600 volts.
Application Versatility
Many models are designed to allow for applications with different types or quantities of lamps. Use of products other
than noted is not covered by UL Listing and/or CSA certification and cannot be warranted.
Audible Noise (Sound)
Electrical equipment, including most fluorescent lamp ballasts, produces some noise. Care must be taken to select a
ballast with the proper sound rating for a particular lighting
installation. Ballast sound will be noticeable only when it
exceeds the ambient sound level.
Although no industry standards currently exist, the generally
accepted criteria for sound rating specifications are as follows:
Average
Ambient Noise
Ballast
Recommendation
< 30 decibels
A
Noisy Office or Retail 31-36 decibels
B
Factory, Outdoor
C
Location
Typical Office
> 36 decibels
Remote Mounting
Excessive hot or cold temperatures, audible noise requirements or a desire to operate lamps in more than one fixture with the
same ballast (master/slave), may make it desirable to mount the ballast remotely. Care must be taken to allow for ballast heat dissipation and proper grounding.
In any application, the wire used to extend leads must be at least as large as the wire supplied on the ballast (18 AWG) with an
insulation rating of 1000 VAC at 90°C.
Lead lengths in excess of those noted cause loading effects that can dramatically impact ballast performance and void the warranty.
Electromagnetic and hybrid ballasts may be remote mounted according to the table below:
Wire Size
800 mA - HO
1500 mA - VHO
Instant Start
(Slimline)
Red/Blue
Leads
Yellow
Leads
Red/Blue
Leads
Yellow
Leads
All Leads
544’
340’
214’
134’
84’
52’
30’
384’
240’
150’
94’
60’
36’
20’
272’
170’
107’
67’
42’
26’
21’
192’
120’
75’
47’
30’
18’
15’
544’
340’
214’
134’
84’
52’
30’
PAGE 1-5
Fluorescent-Electromagnetic
#6
#8
#10
#12
#14
#16
#18
30-40 Watt
Rapid Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
PERFORMANCE
Fluorescent-Electromagnetic
Operating Temperature
Most fluorescent ballasts and lamps are designed to provide
optimum performance at ambient temperature of 77˚F. Three
key performance attributes can be impacted by the ambient
(room) temperature of the installation:
•
Lamp Starting Dependability
Fluorescent lamps are inherently more difficult to
start at low temperatures. All ballasts have
limitations as to their ability to start lamps at low
ambient temperatures. In this catalog, the low
starting point for each lamp/ballast combination
appears in the column marked “Minimum Starting
Temperature.”
•
Light Output
Optimum light output from fluorescent lamps is
achieved when the lamp wall is at 100-110°F.
Any substantial excursion (either colder or warmer)
will result in a reduction in light output.
RECOMMENDATIONS...
• Selection of a proper ballast to match the
requirements of the lamp, fixture, voltage and
installation.
•
Mounting of ballast within the fixture with as much
surface contact as possible between the ballast and
metal portions of the fixture.
•
The use of heat-conducting dissipators (radiators),
if necessary, which increase surface contact between
the ballast and fixture.
•
If necessary, locate the ballast in a remote, cooler
area outside the fixture.
•
Planned lamp maintenance – the organized
replacement of failed and failing lamps, particularly
with Preheat or Slimline Systems.
•
Use of special LOW HEAT (-LH) rise, VERY LOW
HEAT (-VLH) rise and SUPER LOW HEAT (-SLH)
rise ballasts where available and necessary.
• Ballast Life
A fluorescent lamp ballast, like any other electrical
device, generates heat during its normal operation.
Ballast temperatures should be kept as low as
possible. Maximum dissipation of heat through
fixture design and proper ballast installation will
help. Although excessive temperature may not cause
the ballast to fail immediately, it can dramatically
shorten ballast life. To assure maximum life, the
ballast case temperature should not exceed 90˚C.
CAUSES OF BALLAST OVERHEATING:
• Incorrect primary voltage or frequency
• Incorrect size, type or number of lamps
• Failed lamp starter
• Incorrect wiring
• Poor heat dissipation due to surrounding
insulation
• Sealed (Vapor Tight) Fixtures - Unusual heat
build-up due to lack of ventilation in fixtures
may cause thermal (on/off) cycling of certain
ballasts. Consult Universal for specific
recommendations.
PAGE 1-6
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
LOW-LEAKAGE CURRENT TO GROUND BALLASTS
Many one- and two-lamp, 30- and 40-watt high power Rapid Start ballasts – and two- and three-lamp 20-watt Trigger Start
ballasts – meet requirements for “low-leakage-current-to-ground.” Those most frequently used in low-leakage applications are
listed below.
Line Voltage
Lamps
@ 60Hz
(1)F40T12/RS
120
(2)F40T12/RS
120
(1)F40T12/RS
277
(2)F40T12/RS
277
(2)F20T12
120
Maximum
Leakage
To Ground
30uA
30uA
50uA
50uA
15uA
Catalog Number
412-L-SLH-TC-P
446-L-SLH-TC-P
458-L-SLH-TC-P
443-L-SLH-TC-P
447-LR-VLH-TC-P
Other ballasts can also be manufactured to meet low-leakage requirements. Consult Universal’s Technical Engineering Services
Department at 1-800-BALLAST for complete information regarding low-leakage ballasts.
TYPE 1 BALLASTS
All Universal outdoor non-weatherproof magnetic ballasts (except those for sign applications) are designed to meet UL requirements for Type 1 use (metal enclosure required for wet or damp locations).
BALLASTS FOR GERMICIDAL LAMPS
Universal manufactures ballasts to operate germicidal lamps. When ordering, make sure the ANSI designation of the germicidal
lamp matches exactly with the ballast’s recommended application.
Several typically encountered germicidal lamps are listed below along with the proper Universal ballast for their operation.
Contact Universal’s Technical Engineering Services at
1-800-BALLAST
for additional information or applications not listed
Germicidal Lamp
Universal Ballast
See Page Number
(1)G15T8
200-H2
1-46 – 1-48
Fluorescent-Electromagnetic
All high power factor ballasts are equipped with capacitors.
Oil-filled capacitors contain non-resetting internal protection
and are manufactured without PCBs.
PAGE 1-7
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Specifications
TYPICAL SPECIFICATIONS
FOR ELECTROMAGNETIC BALLASTS
1. Ballasts shall be certified energy saving magnetic type and operate lamps at a frequency of 60 Hz.
2. Ballasts shall be specifically designed to operate (Quantity & Type) lamps.
3. Ballasts shall operate from 60 Hz input source of _____ volts, and tolerate sustained variations of +5%-10%
with no damage to the ballasts.
4. Ballasts shall provide transient immunity as specified by ANSI C62.41-1991, Location Category A1.
5. Ballasts shall provide starting sequence consistent with ANSI standard C82.1.
6. Ballasts shall tolerate sustained open circuit and short circuit output conditions with no damage to the ballasts.
7. Ballasts shall be:
– UL LISTED as Class P, and for use in indoor or Type 1 outdoor applications.
– CSA CERTIFIED where applicable (120 and 347 volt models).
8. Ballasts shall tolerate operation, in most fixtures, at ambient temperatures up to 105°F (40°C). Ballast enclosure is limited to 90˚C maximum temperature.
9. Ballasts shall have Power Factor greater than .90.
10. Lamp Current Crest Factor (ratio of peak to RMS lamp current) shall be 1.7 or less in accordance with lamp
manufacturers recommendation and ANSI C82.1.
– 1.85 or less for instant start slimline (also per ANSI C82.1).
11. Ballasts shall have a Ballast Factor greater than .925 per ANSI C82.1.
Fluorescent-Electromagnetic
– .95 or greater for HO and VHO applications.
12. Input current Total Harmonic Distortion shall not exceed .32 per ANSI C82.1.
13. Ballasts shall be fully encapsulated (potted) to ensure maximum thermal and structural integrity.
14. Manufacturer shall provide written warranty against defects in material or workmanship.
15. Manufacturer shall have been manufacturing electromagnetic ballasts for at least twenty years.
16. Ballasts shall be manufactured in North America.
17. Universal model ___________ (or approved equal).
PAGE 1-8
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Lead Lengths
Lead Quantities (per color), Exits (L=Left, R=Right, B=Bottom) and Lengths (in inches, +/- 1”)
Black/White
Black/White
White
Red
Blue
Yellow
Blue/White
Brown
Red/White
R
R
12
27
2
R
12
1
L 12
1
2
R
L
12
12
2
L
12
2
L
12
Length
Quanti
ty
Exit
Length
Quanti
ty
Exit
Length
2
2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electromagnetic
200-C-S-P
1 R
12
2 R
12
1 R
12
1 R
12
1 R
12
200-H2
2 8-15
202-B-TC-P
1 L
12
1 L
12
1 R
12
202-SB-TC-P 1
12
2
12
1
26
1
12
1
12
213-TC-P
1 L
12
1 L
12
1 R
12
1 R
12
412-L-SLH-TC-P
1 L 12
1 L
12
2 L
12
412-L-TC-P
1 L 12
1 L
25
2 L
37
413-C-TC-P
1 L
9
1 L
29
2 R
30
1 L
29
420-L-TC-P
1 L
20
1 L
20
2 R
24
2 R
24
2 L
36
443-L-SLH-TC-P 1 L
12
1 L
12
2 R
12
2 R
12
2 L
12
445-RS-WS-TC-P 1 L
12
2
12
2 R
12
1 R
12
446-L-SLH-TC-P 1 L
12
1 L
12
2 R
12
2 R
12
2 L
12
446-LR-TC-P
1 L
22
1 L
22
2 R
26
2 R
26
2 L
36
447-LR-TC-P 1 L
10
1 L/R 10
2 R
13
2 R
13
2 L
18
447-LR-VLH-TC-P 1 L
10
1 L
10
2 R
13
2 R
13
2 L
18
458-L-SLH-TC-P
1 L 12
1 L
12
2 L
12
2 R
12
480-SLH-TC-P 1 L
18
1 L
18
2 R
46
2 R
46
2 L
65
480-XLH-TC-P 1 L
12
1 L
12
2 R
12
2 R
12
2 L
12
481-LH-TC-P 1 L
10
1 L
10
2 R
44
2 L
60
487-SLH-TC-P 1 L
18
1 L
18
2 R
46
2 R
46
2 L
65
487-XLH-TC-P 1 L
12
1 L
12
2 R
12
2 R
12
2 L
12
490-XLH-TC-P 1 L
18
1 L
18
2 R
33
2 R
33
2 L
51
502-A-TC-P
1 L
12
1 L
12
2 R
12
1 L
12
2 R
12
532-BR-TC-P 1 L
12
1 L
12
1 R
12
1 R
12
540-L-TC-P
1 L
20
1 L
20
2 R
25
2 R
25
2 L
37
546-B-TC-P
1 L 12
1 L
12
2 R 12
1 L 12
547-RS-WS-TC-P 1 L 12
2 L/R 12
2 R 12
1 R 12
554-L-TC-P
1 L 12
1 L
12
2 R 12
2 R 12
2 L 12
564-L-TC-P
1 L 10
1 L
10
2 R 13
2 R 13
2 L 16
567-L-TC
1 L 10
1 L
10
2 R 13
2 R 13
2 L 16
573-L-TC-P
1 L 12
1 L
12
2 R 12
2 R 12
2 L 12
595-L-TC-P
1 L 20
1 L
20
2 R 24
2 R 24
2 L 36
597-L-TC-P
1 L 10
1 L
10
2 R 13
2 R 13
2 L 16
631-LH-TC-P 1 L 18
1 L
18
2 R 20
2 R 20
2 L 32
698-L-SLH-TC 1 L 22
1 L
22
2 R 26
2 R 26
2 L 36
726-L-VLH-WS-TC-P 1 L 12
1 L
12
2 L 12
2 R 12
4 L/R 12
757-XLH-TC
1 L 18
1 L
18
2 R 46
2 R 46
2 L 65
778-XLH-TC
1 L 18
1 L
18
2 R 33
2 R 33
2 L 51
789-SLH-TC-P 1 L
10
1
L 10
2 R
10
2 R 10
2
L
10
806-BR-TC-P 1 L 68
1
L 68
1 R
44
1 R 44
806-SLH-TC-P 1 L 12
1
L 12
1 R
12
1 R 12
808-BR-TC-P 1 L 68
1
L 68
1 R
44
1 R 44
822-BR-TC-P
1 L
8
1
L 68
1 R
44
827-SLH-TC-P 1 L 12
1
L 12
1 R
12
1 R 12
828-BR-TC-P
1
12
1
L 12
1 R
12
831-TC
1 L 73
1 L
73
1 R 49
1 R 49
881-BR-TC-P 1 L 12
1
L 12
1 R
12
1 R 12
897-SLH-TC
1 L 12
1
L 12
1 R
12
1 R 12
930-K-TC-P
1 L 12
1
L 12
2 R
12
2 R 12
2
L 12
931-LH-TC-P 1 L 12
1
L 12
2 R
12
2 R 12
2
L 12
937-K-TC-P
1 L 12
1
L 12
2 R
12
2 R 12
2
L 12
CF1320H2P 1,1 L,R 9,18
M232SR120C 1 L 20
1
L 20
2 R
24
2 R 24
2
L 36
M232SR277C 1 L 20
1
L 20
2 R
24
2 R 24
2
L 36
W-589-D-TC-P 1 L 12
1 L 12
2 R 12
2 R
12
2 L 12
4105F2P
2 L 10
4105P
2 L 12
PAGE 1-9
Quanti
ty
Exit
Length
Quanti
ty
Exit
Length
Quanti
ty
Exit
Length
Quanti
ty
Exit
Length
Quanti
ty
Exit
Length
Quanti
ty
Exit
Length
Quanti
ty
Exit
Catalog
#
Black
T8
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
• 265 mA
High Output Lamps
• 4´ Lamp Applications
• OcTek™ Series Featured
Fluorescent-Electromagnetic
FOR F32T8 and F32T8/U LAMPS
T8 U-Shaped Lamps
Input
Power Ballast
(Watts) Factor
Lamp Certification
Line
Catalog
Qty. Descr.
Volts
Number NOM
F32T8 - High Power Factor OcTek®
2 Rapid
120 M232SR120C
•
•
• •
2 Rapid
277 M232SR277C
•
•
•
F32T8/U - High Power Factor OcTek™
2 Rapid
120 M232SR120C
•
•
• •
2 Rapid
277 M232SR277C
•
•
•
Line
Current
(Amps)
Overall Dimensions
Draw #
L
W
D2
9 1/2
2 3/8
WIRING DIAGRAMS
Mounting Dimensions
H
M
X
1 1/2 8 57/64
1
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
.65
.28
74
74
.95
.95
1.28
1.28
< 1.7
< 1.7
< 20
< 20
50/10
50/10
A
A
1
1
D2
D2
.65
.28
74
74
.95
.95
1.28
1.28
< 1.7
< 1.7
< 20
< 20
50/10
50/10
A
A
1
1
D2
D2
Line
H
M
L
W
Ballast
Efficacy Crest THD
Factor Factor
%
Black
White
Yellow
Yellow
BALLAST
Blue
Blue
Red
Red
LAMP
LAMP
D
Diagram 1 1
DIAGRAM
PAGE 1-10
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
T12
• 430 and 460 mA
• 3´ and 4´ Lamp Applications
High Output Lamps
FOR F30T12, F30T12ES, and F40T12 LAMPS
NOM
Line
Input
Current Power Ballast Efficacy
(Amps) (Watts) Factor Factor
Ballast
Crest
THD
Start
Factor
%
Temp
Min. F/C
Sound Wiring
Rating Diag.
Dim.
.66
.66
79
79
.90
.95
1.14
1.21
< 1.9
< 1.7
< 20
< 20
0/-18
60/15
A
A
1
1
D4
D2
•
.63
37
.72
1.95
< 1.7
< 10
50/10
A
8
D1
.58
.57
68
67
.86
.89
1.26
1.33
< 1.9
< 1.9
< 20
< 20
60/15
50/10
A
A
1
1
D4
D2
•
•
•
•
.45
.19
.62
.75
.80
.34
.27
52
51
72
89
92
90
92
.95
.95
.85
.94
.88
.95
.95
1.83
1.86
1.18
1.06
0.96
1.06
1.03
< 1.7
< 1.7
< 1.7
< 1.7
< 1.7
< 1.7
< 1.7
< 20
< 20
< 20
< 20
< 20
< 20
< 20
50/10
50/10
50/10
50/10
0/-18
50/10
50/10
A
A
A
A
A
A
A
42
42
1
1
1
1
1
D2
D2
D2
D2
D4
D2
D2
.53
36
.61
1.69
< 1.7
< 20
50/10
A
8
D1
•
❉ For Residential Use Only
★ Not for use with “U” lamps
◆ Not for use with Energy Saver “U” lamps
✚ Operates at 50 or 60 Hz
n For Replacement Only
X For Distribution Only
Overall Dimensions
Mounting Dimensions
Draw #
L
W
H
M
X
D1
6 7/16 1 7/8 1 1/2
6
D2
9 1/2
2 3/8 1 1/2 8 57/64 1 11/16
D4
9 1/2
2 3/8 1 11/16 8 57/64 1 11/16
WIRING DIAGRAMS
Line
Black
White
Yellow
Yellow
BALLAST
Black
White
Blue
Blue
Red
Red
Blue
BALLAST
Red
Red
LAMP
H
LAMP
M
L
W
LAMP
Diagram 1
DIAGRAM 1
D
Line
Use disconnect
lampholder only
Diagram 8
DIAGRAM 8
Line
Black
White
Red
Red
BALLAST
Blue
Blue
LAMP
DIAGRAM
42
Diagram 42
PAGE 1-11
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electromagnetic
Lamp
Certification
Line
Catalog
Qty. Descr.
Volts
Number
F30T12 - High Power Factor
2 Rapid
120 W-589-D-TC-Pn
•
•
2 Rapid
120 573-L-TC-PX
•
•
F30T12 - Normal Power Factor
1 Rapid
120 413-C-TC-P❉
•
•
F30T12ES - High Power Factor
2 Rapid
120 W-589-D-TC-Pn
•
•
2 Rapid
120 573-L-TC-PX
•
•
F40T12- High Power Factor
1 Rapid
120 412-L-SLH-TC-P★n •
•
•
•
1 Rapid
277 458-L-SLH-TC-P★n •
•
•
•
2 Hybrid
120 420-L-TC-P◆
•
•
•
•
2 Rapid
120 446-L-SLH-TC-Pn •
•
•
•
2 Rapid
120 W-589-D-TC-Pn
•
•
2 Rapid
277 443-L-SLH-TC-Pn •
•
•
•
2 Rapid
347 698-L-SLH-TC
•
•
•
•
F40T12- Normal Power Factor
1 Rapid
120 413-C-TC-P❉
•
•
T12
High Output Lamps
• 4´ Energy Saver Lamp
Applications
• Energy Efficient
FOR F40T12ES, F40T12/U, F40T12ES/U, F48“ 25W/UTLS
AND WORKLITE 25 LAMPS
Fluorescent-Electromagnetic
T8 U-Shaped Lamps
Lamp
Certification
Line
Catalog
Qty. Descr.
Volts
Number
F40T12ES - High Power Factor
1 Rapid
120 412-L-SLH-TC-P★n •
•
•
•
1 Rapid
277 458-L-SLH-TC-P★n •
•
•
•
2 Hybrid
120 420-L-TC-P◆
•
•
•
•
2 Rapid
120 446-L-SLH-TC-Pn •
•
•
•
2 Rapid
277 443-L-SLH-TC-Pn •
•
•
•
2 Rapid
347 698-L-SLH-TC •
•
•
F40T12ES - Normal Power Factor
1 Rapid
120 413-C-TC-P❉
•
•
F40T12 /U - High Power Factor
2 Hybrid
120 420-L-TC-P◆
•
•
•
•
2 Rapid
120 446-L-SLH-TC-Pn •
•
•
•
•
•
2 Rapid
120 W-589-D-TC-Pn
2 Rapid
277 443-L-SLH-TC-Pn •
•
•
•
2 Rapid
347 698-L-SLH-TC •
•
•
F40T12ES/U - High Power Factor
2 Rapid
120 446-L-SLH-TC-Pn •
•
•
•
2 Rapid
277 443-L-SLH-TC-Pn •
•
•
•
2 Rapid
347 698-L-SLH-TC •
•
•
F48”25W/UTLS & WORKLITE - Normal Power Factor
1 Rapid
120 413-C-TC-P❉
•
•
❉
★
◆
n
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
• 430 and 460 mA
NOM
Line
Input
Current Power Ballast Efficacy
(Amps) (Watts) Factor Factor
Ballast
Crest
THD
Start
Factor
%
Temp
Min. F/C
Sound Wiring
Rating Diag.
Dim.
•
•
•
•
.38
.17
.50
.65
.28
.24
44
44
59
74
74
78
.88
.88
.80
.90
.90
.90
2.00
2.00
1.36
1.22
1.22
1.15
< 1.9
< 1.85
< 1.9
< 1.9
< 1.9
< 1.9
< 20
< 20
< 20
< 20
< 20
< 20
60/15
60/15
60/15
60/15
60/15
60/15
A
A
A
A
A
A
42
42
1
1
1
1
D2
D2
D2
D2
D2
D2
•
.61
33
.68
2.06
< 1.9
< 20
60/15
A
8
D1
•
•
.64
.76
.84
.34
.27
74
90
97
92
92
.83
.93
.92
.95
.93
1.12
1.03
0.95
1.03
1.01
< 1.7
< 1.7
< 1.7
< 1.7
< 1.7
< 32
< 20
< 20
< 20
< 20
50/10
50/10
0/-18
50/10
50/10
A
A
A
A
A
1
1
1
1
1
D2
D2
D4
D2
D2
•
•
.65
.28
.24
74
74
78
.90
.90
.90
1.22
1.22
1.15
< 1.9
< 1.9
< 1.9
< 20
< 20
< 20
60/15
60/15
60/15
A
A
A
1
1
1
D2
D2
D2
•
.51
32
.90
2.79
< 1.7
< 20
50/10
A
8
D1
For Residential Use Only
Not for use with “U” lamps
Not for use with Energy Saver “U” lamps
For Replacement Only
Overall Dimensions
Draw #
L
W
D1
6 7/16 1 7/8
D2
9 1/2
2 3/8
11/16
WIRING DIAGRAMS
Mounting Dimensions
H
M
X
1 1/2
6
1 1/2 8 57/64
1
Line
Black
White
Yellow
Yellow
BALLAST
Black
White
Blue
Blue
Red
Red
Blue
BALLAST
Red
Red
LAMP
H
LAMP
M
L
W
LAMP
Diagram 1
DIAGRAM 1
D
Line
Use disconnect
lampholder only
Diagram 8
DIAGRAM
8
Line
Black
White
Red
Red
BALLAST
Blue
Blue
LAMP
Diagram 42
DIAGRAM 42
PAGE 1-12
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
T12
HO
• 800 mA
• 2-3 1/2´ Lamp Applications
• Standard & Weatherproof Models
High Output Lamps
FOR F24, F30, F36, F42 AND F48T12HO LAMPS
F24T12HO - High Power Factor
2 Rapid 120 490-XLH-TC-P
2 Rapid 120 631-LH-TC-P❁
2 Rapid 347 778-XLH-TC
F36T12HO - High Power Factor
2 Rapid 120 490-XLH-TC-P
2 Rapid 120 631-LH-TC-P✪
2 Rapid 347 778-XLH-TC
F42T12HO - High Power Factor
2 Rapid 120 490-XLH-TC-P
F48T12HO - High Power Factor
1 Rapid 120 481-LH-TC-P▼
1 Rapid 120 490-XLH-TC-P▼
1 Rapid 120 631-LH-TC-P▼
1 Rapid 347 778-XLH-TC▼
2 Rapid 120 490-XLH-TC-P
2 Rapid 120 631-LH-TC-P
2 Rapid 347 778-XLH-TC
Input
Power Ballast
(Watts) Factor
Line
Current
(Amps)
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
•
•
•
•
•
.95
1.13
.31
103
100
103
.81
.83
.81
0.79
0.83
0.79
< 2.0
< 2.0
< 2.0
> 32
< 32
> 32
-20/-29
-20/-29
-20/-29
B
B
B
1
1
1
D7
D6
D7
•
•
•
•
•
1.06
1.20
.41
121
122
141
.84
.85
.80
0.69
0.69
0.57
< 2.0
< 1.9
< 2.0
< 32
< 20
< 32
50/10
-20/-29
-20/-29
B
B
B
1
1
1
D7
D6
D7
•
•
1.12
130
.86
0.66
< 2.0
< 32
50/10
B
1
D7
•
•
•
•
•
•
•
•
•
•
•
•
.79
.82
1.05
.32
1.18
1.25
.42
82
82
82
83
139
137
139
.84
.81
.83
.79
.87
.85
.86
1.02
0.99
1.02
0.95
0.63
0.62
0.62
< 1.9
< 2.0
< 1.9
< 2.0
< 2.0
< 1.7
< 2.0
> 32
> 32
< 32
> 32
< 20
< 20
< 32
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
B
B
B
B
B
B
B
12
15
15
15
1
1
1
D7
D7
D6
D7
D7
D6
D7
❁ Power Factor Corrected to 75% for (2) F24T12HO
✪ Power Factor Corrected to 85% for (2) F36T12HO
▼ Power Factor Corrected to >70%
XFor Distribution Only
See page 1-16 for Dimensions and Wiring Diagrams
PAGE 1-13
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electromagnetic
See page 1-3 for additional information on weatherproof applications.
Lamp Certification
Line
Catalog
NOM
Qty. Descr.
Volts
Number
T12
HO
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
• 800-840 mA
• 4´-5´4´´ Lamp Applications
High Output Lamps
• Standard and Weatherproof
Models
Fluorescent-Electromagnetic
FOR F48T12HOES, F60T12HO AND
F64T12HO LAMPS
Lamp Certification
Line
Catalog
NOM
Qty. Descr.
Volts
Number
F48T12HOES - High Power Factor
1 Rapid 120 481-LH-TC-P▼
1 Rapid 120 490-XLH-TC-P▼
1 Rapid 120 631-LH-TC-P▼
1 Rapid 347 778-XLH-TC▼
2 Rapid 120 490-XLH-TC-P
2 Rapid 120 631-LH-TC-P
2 Rapid 347 778-XLH-TC
F60T12HO - High Power Factor
1 Rapid 120 481-LH-TC-P
1 Rapid 120 490-XLH-TC-P
1 Rapid 120 631-LH-TC-P▼
1 Rapid 347 778-XLH-TC▼
2 Rapid 120 490-XLH-TC-P
2 Rapid 347 778-XLH-TC
F64T12HO - High Power Factor
1 Rapid 120 481-LH-TC-P
1 Rapid 120 490-XLH-TC-P
1 Rapid 347 778-XLH-TC▼
2 Rapid 120 490-XLH-TC-P
2 Rapid 347 778-XLH-TC
▼ Power Factor Corrected to >70%
X For Distribution Only
Input
Power Ballast
(Watts) Factor
Line
Current
(Amps)
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
•
•
•
•
•
•
•
•
•
•
•
•
.77
.80
1.03
.31
1.07
1.15
.39
75
76
75
78
124
124
126
.79
.78
.77
.75
.83
.80
.81
1.05
1.03
1.03
0.97
0.67
0.64
0.64
< 1.9
< 2.0
< 1.9
< 2.0
< 2.0
< 1.9
< 2.0
> 32
> 32
< 32
> 32
< 32
< 20
< 32
60/15
60/15
60/15
60/15
60/15
60/15
60/15
B
B
B
B
B
B
B
12
15
15
15
1
1
1
D7
D7
D6
D7
D7
D6
D7
•
•
•
•
•
•
•
•
•
•
.86
.92
1.08
.34
1.42
.49
100
99
94
96
169
169
.87
.83
.85
.82
.89
.88
0.87
0.84
0.90
0.85
0.53
0.52
< 1.9
< 2.0
< 1.7
< 2.0
< 2.0
< 2.0
< 32
> 32
< 32
> 32
< 20
< 20
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
B
B
B
B
B
B
12
15
15
15
1
1
D7
D7
D6
D7
D7
D7
•
•
•
•
•
•
•
•
.90
.93
.35
1.50
.52
102
101
103
178
178
.87
.84
.82
.89
.93
0.85
0.83
0.80
0.50
0.52
< 1.9
< 1.9
< 2.0
< 1.9
< 2.0
< 32
> 32
> 32
< 20
< 20
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
B
B
B
B
B
12
15
15
1
1
D7
D7
D7
D7
D7
See page 1-16 for Dimensions and Wiring Diagrams
PAGE 1-14
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
T12
HO
• 800 - 840 mA
• 6´ - 8´ Lamp Applications
High Output Lamps
• Standard, Weatherproof
& Tanning Models
FOR F72T12HO, F84T12HO, F96T12HO
AND F96T12HOES LAMPS
F72T12HO - High Power Factor
1 Rapid 120 481-LH-TC-P
1 Rapid 120 490-XLH-TC-P
1 Rapid 347 778-XLH-TC✜
2 Rapid 120 480-SLH-TC-P
2 Rapid 120 480-XLH-TC-Pn
2 Rapid 120 490-XLH-TC-P
2 Rapid 277 487-SLH-TC-P
2 Rapid 277 487-XLH-TC-Pn
2 Rapid 347 778-XLH-TC
F84T12HO - High Power Factor
1 Rapid 120 481-LH-TC-P
2 Rapid 120 480-SLH-TC-P
2 Rapid 120 480-XLH-TC-Pn
2 Rapid 277 487-SLH-TC-P
2 Rapid 277 487-XLH-TC-Pn
F96T12HO - High Power Factor
1 Rapid 120 481-LH-TC-P
1 Rapid 120 490-XLH-TC-P
1 Rapid 347 778-XLH-TC
2 Rapid 120 480-SLH-TC-P
2 Rapid 120 480-XLH-TC-Pn
2 Rapid 277 487-SLH-TC-P
2 Rapid 277 487-XLH-TC-Pn
F96T12HOES - High Power Factor
1 Rapid 120 481-LH-TC-P
1 Rapid 120 490-XLH-TC-P
1 Rapid 347 778-XLH-TC
2 Rapid 120 480-SLH-TC-P
2 Rapid 120 480-XLH-TC-Pn
2 Rapid 277 487-SLH-TC-P
2 Rapid 277 487-XLH-TC-Pn
✜ Power Factor Corrected to >85%
nFor Replacement Only
X For Distribution Only
Input
Power Ballast
(Watts) Factor
Line
Current
(Amps)
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
.92
.95
.35
1.69
1.69
1.50
.74
.78
.54
106
107
106
196
196
177
197
208
187
.89
.86
.84
.97
.97
.92
.96
.95
.95
0.84
0.80
0.79
0.49
0.49
0.52
0.48
0.46
0.51
< 1.9
< 2.0
< 2.0
< 1.9
< 1.9
< 1.7
< 1.7
< 1.7
< 1.7
< 32
> 32
> 32
< 20
< 20
< 10
< 20
< 20
< 10
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
B
B
B
B
B
B
B
B
B
12
15
15
1
1
1
1
1
1
D7
D7
D7
D7
D7
D7
D7
D7
D7
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1.02
1.87
1.98
.87
.89
119
220
235
235
244
.88
.93
.93
.97
.95
0.74
0.42
0.40
0.41
0.39
< 1.9
< 1.9
< 1.9
< 1.9
< 1.9
< 32
< 20
< 20
< 20
< 20
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
B
B
B
B
B
12
1
1
1
1
D7
D7
D7
D7
D7
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1.16
1.10
.41
1.99
2.15
.87
.95
136
124
137
237
246
237
249
.91
.85
.83
.96
.96
.95
.97
0.67
0.65
0.71
0.41
0.39
0.40
0.39
< 1.9
< 2.0
< 2.0
< 1.7
< 1.7
< 1.7
< 1.7
< 20
< 20
< 32
< 10
< 10
< 10
< 10
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
B
B
B
B
B
B
B
12
15
15
1
1
1
1
D7
D7
D7
D7
D7
D7
D7
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
.96
.94
.37
1.72
1.80
.75
.83
110
106
116
202
209
205
223
.84
.81
.83
.89
.89
.91
.92
0.77
0.76
0.71
0.44
0.43
0.44
0.41
< 1.9
< 2.0
< 2.0
< 1.9
< 1.9
< 1.9
< 1.9
< 32
< 32
< 32
< 20
< 20
< 20
< 20
60/15
60/15
60/15
60/15
60/15
60/15
60/15
B
B
B
B
B
B
B
12
15
15
1
1
1
1
D7
D7
D7
D7
D7
D7
D7
See page 1-16 for Dimensions and Wiring Diagrams
PAGE 1-15
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electromagnetic
See page 1-3 for additional information on weatherproof applications.
Lamp Certification
Line
Catalog
NOM
Qty. Descr.
Volts
Number
Fluorescent-Electromagnetic
T12
HO & VHO
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
Overall Dimensions
Mounting Dimensions
Draw #
L
W
H
M
X
D6
11 3/4 3 1/8 1 25/32 11 9/64
2
D7
11 3/4 3 3/16 1 5/8 11 9/64
2
D8 14 5/16 3 3/16 2 5/8 13 3/4
2
D9 19 3/16 3 3/16 2 5/8 18 5/8
2
WIRING DIAGRAMS
Line
Black
White
Yellow
Yellow
BALLAST
Blue
Blue
Red
Red
LAMP
LAMP
Diagram 1
H
DIAGRAM 1
M
L
W
D
Line
Black
White
Blue
Blue
BALLAST
Red
Red
Black
Red
Red
White
BALLAST
Yellow
Yellow
Blue
Blue
LAMP
LAMP
Diagram 12
DIAGRAM 12
Line
INSULATE EACH YELLOW LEAD
INDIVIDUALLY
DIAGRAM
15
Diagram 15
PAGE 1-16
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
T12
VHO
• 1500 - 1580 mA
• 4´ and 6´ VHO, SHO & PG Lamp
Applications
High Output Lamps
FOR F72PG17, F72T12VHO, F96PG17, F96PG17ES,
F96T12VHO AND F96T12VHOES LAMPS
F72PG17 - High Power Factor
2 Rapid 120 930-K-TC-P❷X
2 Rapid 120 931-LH-TC-P①X
2 Rapid 277 937-K-TC-P❷X
F72T12VHO - High Power Factor
2 Rapid 120 930-K-TC-P❷X
2 Rapid 120 931-LH-TC-P①X
2 Rapid 277 937-K-TC-P❷X
F96PG17 - High Power Factor
2 Rapid 120 930-K-TC-P❷X
2 Rapid 120 931-LH-TC-P①X
2 Rapid 277 937-K-TC-P❷X
F96PG17ES - High Power Factor
2 Rapid 120 931-LH-TC-PX
F96T12VHO - High Power Factor
2 Rapid 120 930-K-TC-P❷X
2 Rapid 120 931-LH-TC-P①X
2 Rapid 277 937-LH-TC-P❷X
F96T12VHOES - High Power Factor
2 Rapid 120 931-LH-TC-PX
Input
Power Ballast
(Watts) Factor
Line
Current
(Amps)
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
•
•
•
•
•
•
3.05
2.77
1.26
360
303
341
.95
.82
.92
0.26
0.27
0.27
< 1.7
< 1.7
< 1.7
< 20
< 20
< 20
-20/-29
-20/-29
-20/-29
D
D
D
1
1
1
D8
D8
D8
•
•
•
•
•
•
3.05
2.77
1.26
360
303
341
.95
.80
.91
0.26
0.26
0.27
< 1.7
< 1.7
< 1.7
< 20
< 20
< 20
-20/-29
-20/-29
-20/-29
D
D
D
1
1
1
D8
D8
D8
•
•
•
•
•
•
3.83
3.25
1.61
446
380
429
.98
.83
.95
0.22
0.22
0.22
< 1.7
< 1.7
< 1.7
< 20
< 20
< 20
-20/-29
-20/-29
-20/-29
D
D
D
1
1
1
D8
D8
D8
•
•
2.88
333
.75
0.22
< 1.7
< 32
60/15
D
1
D8
•
•
•
•
•
•
4.10
3.83
1.64
482
431
450
.99
.93
.95
0.21
0.22
0.21
< 1.7
< 1.7
< 1.7
< 20
< 20
< 20
-20/-29
-20/-29
-20/-29
D
D
D
1
1
1
D8
D8
D8
•
•
3.09
361
.83
0.23
< 1.7
< 20
60/15
D
1
D8
❷ Cannot be used with T10 or T10J lamps
①May be used with equivalent T10 or T10J Lamps
X For Distribution Only
See page 1-18 for Dimensions and Wiring Diagrams
PAGE 1-17
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electromagnetic
Lamp Certification
Line
Catalog
NOM
Qty. Descr.
Volts
Number
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
• 430 mA
• 20-40 Watt Lamp Applications
CIRCLINE
FOR 20, 22, 32 AND 40 WATT LAMPS
Fluorescent-Electromagnetic
Circline Lamps
Lamp Certification
Line
Catalog
NOM
Qty. Descr.
Volts
Number
FC6T9 (20 Watt) - Normal Power Factor
1 Preheat 120 200-C-S-P♣X
1 Rapid 120 547-RS-WS-TC-PX
FC8T9 (22 Watt) - Normal Power Factor
1 Preheat 120 200-C-S-P♣X
1 Rapid 120 547-RS-WS-TC-P✩X
FC12T9 (32 Watt) - High Power Factor
2 Rapid 120 W-589-D-TC-P❸n
FC12T9 (32 Watt) - Normal Power Factor
1 Preheat 120 202-B-TC-P❶X
1 Preheat 120 202-SB-TC-P♣X
1 Rapid 120 445-RS-WS-TC-P✩X
FC16T9 (40 Watt) - High Power Factor
2 Rapid 120 W-589-D-TC-P❸n
FC16T9 (40 Watt) - Normal Power Factor
1 Rapid 120 445-RS-WS-TC-P✩X
Line
Current
(Amps)
Input
Power Ballast
(Watts) Factor
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Ballast
Efficacy Crest THD
Factor Factor
%
Dim.
•
•
•
•
.40
.64
29
27
1.01
.90
3.47
3.30
< 1.7
< 1.7
<10
< 10
50/10
50/10
A
A
28
29
D11
D1
•
•
•
•
.24
.60
22
30
.93
.85
4.19
2.83
< 1.7
< 1.7
<10
< 10
50/10
50/10
A
A
28
29
D11
D1
•
•
.64
76
.89
1.17
< 1.9
< 20
0/-18
A
1
D4
•
•
•
•
•
•
.67
.67
.60
37
37
35
.91
.91
.68
2.44
2.44
1.97
< 1.7
< 1.7
< 1.7
<10
<10
< 20
50/10
50/10
50/10
A
A
A
22
28
29
D11
D11
D1
•
•
.88
98
.95
0.96
< 1.7
< 20
0/-18
A
1
D4
•
•
.55
33
.60
1.83
< 1.7
< 20
50/10
A
29
D1
✩ Also available in White Cans
♥ Only available in White Cans
♣Starter is built in as an integral component
❶ Requires Starter
❸ May be used with any combination of F30T12/RS, F40T12/RS, FC12T9/RS and FC16T9/RS
nFor Replacement Only
XFor Distribution Only
Overall Dimensions
Mounting Dimensions
Draw #
L
W
H
M
X
D1
6 7/16 1 7/8 1 1/2
6
D4
9 1/2
2 3/8 1 11/16 8 57/64
1
11/16
WIRING DIAGRAMS
Line
Black
White
Yellow
Yellow
BALLAST
S
Blue
Blue
Red
Red
LAMP
LAMP
Blue
White
LAMP
Black
BALLAST
DIAGRAM
Diagram 1 1
Line
H
M
L
W
D
Line
Black
White
Blue
BALLAST
Red
White
Line
Black
White
Diagram 22
DIAGRAM 22
BALLAST
Yellow
Red
Red
Blue
White
LAMP
Mount lamp within 1/2" of
grounded metal reflector
DIAGRAM
Diagram 28 28
PAGE 1-18
Metal contacts
lamp to fixture
DIAGRAM
Diagram 2929
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
T12
• 425-440 mA
• 2´-7´ Lamp Applications
SLIMLINE
Slimline Lamps
• Slimline
FOR F24 - F84T12 LAMPS
◗ Power Factor Corrected to >75%
❏ Use with any combination of F60T12 & F64T12
nFor Replacement Only
Input
Power Ballast
(Watts) Factor
Line
Current
(Amps)
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
.29
60
.96
1.60
< 1.85 < 32
32 / 0
B
40
D6
.70
.34
77
75
.95
.93
1.24
1.24
< 1.85 > 32
< 1.85 < 32
50/10
32 / 0
B
B
39
40
D10
D12
.80
.37
94
94
.92
.92
0.98
0.98
< 1.85 < 20
< 1.85 < 32
50/10
32 / 0
B
B
39
40
D10
D12
.74
.34
86
84
.93
.94
1.09
1.11
< 2.0 < 32
< 1.85 < 32
50/10
32 / 0
B
B
39
40
D10
D12
.79
.35
95
95
.92
.96
0.89
1.01
< 1.85 < 20
< 1.85 < 32
50/10
32 / 0
B
B
39
40
D10
D12
.72
.32
80
82
.91
.94
1.14
1.15
< 2.0
< 2.0
< 32
< 32
60/15
60/15
B
B
39
40
D10
D12
.96
109
.84
0.77
< 1.85 < 32
0/-18
C
39
D6
1.05
119
.84
0.71
< 1.85 < 32
0/-18
C
39
D6
.72
.30
1.13
1.03
.49
.37
81
78
133
120
135
123
.95
.92
1.01
.82
.93
.91
1.17
1.18
0.76
0.69
0.69
0.74
< 1.85
< 1.85
< 1.85
< 1.85
< 1.85
< 1.85
< 32
< 32
< 20
< 32
< 20
< 32
0/-18
0/-18
50/10
0/-18
50/10
50/10
C
C
C
C
C
C
34
34
39
39
40
65
D6
D6
D6
D6
D12
D12
.77
.33
1.26
.55
.42
89
86
143
150
141
.96
.94
.95
.95
.92
1.09
1.09
0.67
0.63
0.65
< 1.85
< 1.85
< 1.85
< 1.85
< 1.85
< 32
< 32
< 20
< 10
< 32
0/-18
0/-18
50/10
50/10
50/10
C
C
C
C
C
34
34
39
40
65
D6
D6
D6v
D12
D12
See page 1-23 for Dimensions and Wiring Diagrams
XFor Distribution Only
PAGE 1-19
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electromagnetic
Lamp Certification
Line
Catalog
Qty. Descr.
Volts
Number NOM
F24T12 - High Power Factor
2 Instant 277 532-BR-TC-P◗X
•
•
F36T12 - High Power Factor
2 Instant 120 213-TC-PX
•
•
•
2 Instant 277 532-BR-TC-P◗X
•
•
F40T12 /IS - Bi Pin - High Power Factor
2 Instant 120 213-TC-PX
•
•
•
2 Instant 277 532-BR-TC-PX
•
•
F42T12 - High Power Factor
2 Instant 120 213-TC-PX
•
•
•
2 Instant 277 532-BR-TC-PX
•
•
F48T12 - High Power Factor
2 Instant 120 213-TC-PX
•
•
•
2 Instant 277 532-BR-TC-PX
•
•
F48T12ES - High Power Factor
2 Instant 120 213-TC-PX
•
•
•
2 Instant 277 532-BR-TC-PX
•
•
F60T12 - High Power Factor
2 Instant 120 881-BR-TC-P❏X
•
•
F64T12 - High Power Factor
2 Instant 120 881-BR-TC-P❏X
•
•
F72T12 - High Power Factor
1 Instant 120 822-BR-TC-P
•
•
•
1 Instant 277 828-BR-TC-PX
•
•
2 Instant 120 806-SLH-TC-Pn •
•
•
• •
2 Instant 120 881-BR-TC-PX
•
•
2 Instant 277 827-SLH-TC-Pn •
•
•
• •
2 Instant 347 897-SLH-TCX
•
•
•
F84T12 - High Power Factor
1 Instant 120 822-BR-TC-P
•
•
•
1 Instant 277 828-BR-TC-PX
•
•
2 Instant 120 806-SLH-TC-Pn •
•
•
• •
2 Instant 277 827-SLH-TC-Pn •
•
•
• •
2 Instant 347 897-SLH-TCX
•
•
•
T12
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
• 425-440 mA
SLIMLINE
• 8´ Lamp Applications
Slimline Lamps
Fluorescent-Electromagnetic
FOR F96T12 AND F96T12ES LAMPS
Lamp Certification
Line
Catalog
Qty. Descr.
Volts
Number NOM
F96T12 - High Power Factor
1 Instant 120 822-BR-TC-P
•
•
•
1 Instant 277 828-BR-TC-PX
•
•
2 Instant 120 806-SLH-TC-Pn •
•
•
• •
2 Instant 277 827-SLH-TC-Pn •
•
•
• •
2 Instant 347 897-SLH-TCX
•
•
F96T12ES - High Power Factor
1 Instant 120 822-BR-TC-P
•
•
•
1 Instant 277 828-BR-TC-PX
•
•
2 Instant 120 806-SLH-TC-Pn •
•
•
• •
2 Instant 277 827-SLH-TC-Pn •
•
•
• •
•
•
2 Instant 347 897-SLH-TCX
Line
Current
(Amps)
Input
Power Ballast
(Watts) Factor
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
.84
.35
1.41
.58
.45
96
93
165
158
151
.95
.93
.95
.93
.89
0.98
1.00
0.57
0.59
0.59
< 1.85
< 1.85
< 1.85
< 1.85
< 1.85
< 32
< 32
< 10
< 10
< 32
0/-18
0/-18
50/10
50/10
50/10
C
C
C
C
C
34
34
39
40
65
D6
D6
D6
D12
D12
.70
.30
1.13
.48
.38
79
79
133
132
121
.90
.96
.91
.89
.86
1.14
1.22
0.68
0.67
0.71
< 2.0
< 2.0
< 2.0
< 2.0
< 2.0
< 32
< 32
< 20
< 20
< 32
60/15
60/15
60/15
60/15
60/15
C
C
C
C
C
34
34
39
40
65
D6
D6
D6
D12
D12
n For Replacement Only
X For Distribution Only
WIRING DIAGRAMS
Overall Dimensions
Mounting Dimensions
Draw #
L
W
H
M
X
D6
11 3/4 3 1/8 1 25/32 11 9/64
2
D10 9 29/64 3 3/32 1 25/32 8 57/64
1
11/16
LAMP
LAMP
Line
LAMP
White
Black
H
White
Red
Black
BALLAST
Red
Blue
Diagram 39
DIAGRAM 39
Line
M
L
W
BALLAST
Diagram 34
DIAGRAM 34
D
LAMP
LAMP
LAMP
Brown
Brown
White
Black
BALLAST
LAMP
Yellow
Yellow
White
Black
Blue
Red
BALLAST
Blue
Red
Line
Line
Diagram 40 40
DIAGRAM
PAGE 1-20
Diagram 65
DIAGRAM 65
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
PREHEAT/
TRIGGER
• 4-13 Watt T5 Lamp Applications
• 14 Watt T8 & T12 Applications
High Output Lamps
FOR F4, F6, F8, F13T5, F14T8
AND F14T12 LAMPS
F6T5 - Normal Power Factor
1 Preheat
120 4105P❶
1 Preheat
120 4105F2P❶
F8T5 - Normal Power Factor
1 Preheat
120 4105P❶
1 Preheat
120 4105F2P❶
F14T8 - Normal Power Factor
1 Preheat
120 200-C-S-P♣X
1 Preheat
120 200-H2❶
F14T12 - High Power Factor
2 Preheat
120 564-L-TC-P
2 Preheat
277 554-L-TC-PX
F14T12 - Normal Power Factor
1 Preheat
120 200-C-S-P♣X
1 Preheat
120 200-H2❶
1 Preheat
120 546-B-TC-P♠X
2 Preheat
120 447-LR-VLH-TC-P❺
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Input
Power Ballast
(Watts) Factor
Line
Current
(Amps)
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
.18
.18
9
9
1.00
1.00
11.11
11.11
< 1.5
< 1.5
10
10
50
50
A
A
21
21
C1
B1
.17
.17
9.5
9.5
1.00
1.00
10.53
10.53
< 1.5
< 1.5
9
9
50
50
A
A
21
21
C1
B1
•
.42
.36
22
19
1.07
.99
4.89
5.15
< 1.7
< 1.7
<10
<10
50/10
50/10
A
A
28
21
D11
E1
•
.39
.17
45
45
.79
.79
1.75
1.76
< 1.7
< 1.9
<20
<20
50/10
50/10
A
A
1
1
D2
D2
•
•
.43
.37
.66
.62
22
20
30
40
1.11
.98
.86
.77
4.96
4.85
2.87
1.95
< 1.7
< 1.7
< 1.7
< 1.7
<10
<10
<10
<20
50/10
50/10
50/10
50/10
A
A
A
A
28
21
8
1
D11
E1
D1
D3
❶ Requires Starter
♣ Starter is built in as an integral component
♠ Requires one circuit interrupting lamp holder
❺ Recommended for enclosed Fixtures Requiring “very low heat” ballasts
XFor Distribution Only
See page 1-24 for Dimensions and Wiring Diagrams
PAGE 1-21
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electromagnetic
Lamp Certification
Line
Catalog
NOM
Qty. Descr.
Volts
Number
PREHEAT/
TRIGGER
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
• 15, 18 & 19 Watt T8 Lamp
Applications
High Output Lamps
• 15 Watt T12 Lamp Applications
Fluorescent-Electromagnetic
FOR F15T8, F18T8, F19T8 AND F15T12 LAMPS
Lamp Certification
Line
Catalog
Qty. Descr.
Volts
Number NOM
F15T8 - High Power Factor
2 Preheat
120 564-L-TC-P
•
•
•
2 Preheat
277 554-L-TC-PX
•
•
F15T8 - Normal Power Factor
1 Preheat
120 200-C-S-P♣X
•
•
1 Preheat
120 200-H2❶
•
•
•
1 Preheat
120 546-B-TC-P♠X
•
•
•
1 Preheat
120 CF1320H2P❶
•
•
2 Preheat
120 447-LR-TC-P
•
•
2 Preheat
120 447-LR-VLH-TC-P❺
•
•
F18T8 - Normal Power
1 Preheat
120 200-C-S-P♣X
•
•
1 Preheat
120 200-H2❶
•
•
•
F19T8 - Normal Power
1 Preheat
120 200-C-S-P♣X
•
•
1 Preheat
120 200-H2❶
•
•
•
F15T12 - High Power
2 Preheat
120 564-L-TC-P
•
•
•
2 Preheat
277 554-L-TC-PX
•
•
F15T12 - Normal Power
1 Preheat
120 200-C-S-P♣X
•
•
1 Preheat
120 200-H2❶
•
•
•
1 Preheat
120 546-B-TC-P♠X
•
•
•
2 Preheat
120 447-LR-TC-P
•
•
2 Preheat
120 447-LR-VLH-TC-P❺
•
•
♣ Starter is built in as an integral component
♠Requires one circuit interrupting lamp holder
❶Requires Starter
❺Recommended for enclosed Fixtures Requiring “very low heat” ballasts
X For Distribution Only
Input
Power Ballast
(Watts) Factor
Line
Current
(Amps)
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
.47
.20
51
51
.91
.89
1.78
1.76
< 1.7
< 1.9
<32
<20
50/10
50/10
A
A
1
1
D2
D2
.36
.32
.55
.26
.50
.53
22
20
25
17
39
38
1.05
1.05
.89
.75
.75
.76
4.86
5.13
3.50
4.55
1.92
2.02
< 1.7
< 1.7
< 1.7
< 1.7
< 1.7
< 1.7
<10
<10
<10
<15
<20
<20
50/10
50/10
50/10
50/10
50/10
50/10
A
A
A
A
A
A
28
21
8
21
1
1
D11
E1
D1
E2
D3
D3
.33
.28
21
19
.91
.80
4.31
4.29
< 1.7
< 1.7
<10
<10
50/10
50/10
A
A
28
21
D11
E1
.31
.26
21
18
.91
.80
4.28
4.33
< 1.7
< 1.7
<10
<10
50/10
50/10
A
A
28
21
D11
E1
.43
.20
44
49
.85
.87
1.91
1.78
< 1.7
< 1.9
<20
<20
50/10
50/10
A
A
1
1
D2
D2
.41
.44
.61
.56
.58
23
21
30
42
40
1.20
1.08
.96
.80
.77
5.26
5.19
3.23
1.90
1.93
< 1.7
< 1.7
< 1.7
< 1.7
< 1.7
<10
<10
<10
<20
<10
50/10
50/10
50/10
50/10
50/10
A
A
A
A
A
28
21
8
1
1
D11
E1
D1
D3
D3
See page 1-24 for Dimensions and Wiring Diagrams
PAGE 1-22
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
PREHEAT/
TRIGGER
• 20-40 Watt T12
Lamp Applications
• 30 Watt T8 Lamp Applications
High Output Lamps
60Hz
FOR F20, F25, F30, F40T12
AND F30T8 LAMPS
Line
Current
(Amps)
Input
Power Ballast
(Watts) Factor
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
.51
.22
55
55
.85
.86
1.55
1.55
< 1.7
< 1.7
<20
<20
50/10
50/10
A
A
1
1
D2
D2
.35
.30
.58
.26
.43
.42
23
20
29
17
37
35
.95
.83
.82
.75
.56
.55
4.15
4.15
2.83
4.55
1.51
1.57
< 1.7
< 1.7
< 1.7
< 1.7
< 1.7
< 1.7
<10
<10
<10
<15
<20
<20
50/10
50/10
50/10
50/10
50/10
50/10
A
A
A
A
A
A
28
21
8
21
1
1
D11
E1
D1
E2
D3
D3
.62
.62
37
39
.97
2.97
2.62
7.62
< 1.7
< 1.7
<10
<10
50/10
50/10
A
A
22
28
D11
D11
.68
.68
37
37
.85
.85
2.28
2.28
< 1.7
< 1.7
<10
<10
50/10
50/10
A
A
22
28
D11
D11
.60
.60
39
39
.77
.77
1.99
1.99
< 1.7
< 1.7
<10
<10
50/10
50/10
A
A
22
28
D11
D11
.68
.68
37
37
.82
.82
2.22
2.22
< 1.9
< 1.9
<10
<10
60/15
60/15
A
A
22
28
D11
D11
See page 1-24 for Dimensions and Wiring Diagrams
♣ Starter is built in as an integral component
❶ Requires Starter
♠ Requires one circuit interrupting lamp holder
❺ Recommended for enclosed Fixtures Requiring
“very low heat” ballasts
X For Distribution Only
PAGE 1-23
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electromagnetic
Lamp Certification
Line
Catalog
Qty. Descr.
Volts
Number NOM
F20T12 - High Power Factor
2 Preheat
120 564-L-TC-P
•
•
•
2 Preheat
277 554-L-TC-PX
•
•
F20T12 - Normal Power Factor
1 Preheat
120 200-C-S-P♣X
•
•
1 Preheat
120 200-H2❶
•
•
•
1 Preheat
120 546-B-TC-P♠X
•
•
•
1 Preheat
120 CF1320H2P❶
•
•
2 Preheat
120 447-LR-TC-P
•
•
2 Preheat
120 447-LR-VLH-TC-P❺
•
•
F30T8 - Normal Power Factor
1 Preheat
120 202-B-TC-P❶X
•
•
1 Preheat
120 202-SB-TC-P♣X
•
•
F30T12 - Normal Power Factor
1 Preheat/RS 120 202-B-TC-P❶X
•
•
1 Preheat/RS 120 202-SB-TC-P♣X
•
•
F40T12 - Normal Power Factor
1 Preheat/RS 120 202-B-TC-P❶X
•
•
1 Preheat/RS 120 202-SB-TC-P ♣X
•
•
F40T12ES - Normal Power Factor
1 Preheat/RS 120 202-B-TC-P❶X
•
•
1 Preheat/RS 120 202-SB-TC-P♣X
•
•
Fluorescent-Electromagnetic
PREHEAT/
TRIGGER
Overall Dimensions
Draw #
L
W
B1
2 3/8
27/32
C1
2 3/4 1 27/32
D1
6 7/16 1 7/8
D2
9 1/2
2 3/8
11/16
D3 6 19/32 2 3/8
D11 6 7/16 1 7/8
E1
3 1/16 1 25/32
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
Mounting Dimensions
H
M
X
1 13/32
2
1 3/32 2 13/32
1 1/2
6
1 1/2 8 57/64
1
1 1/2
1 5/16
1 5/16
6
6
2 3/4
WIRING DIAGRAMS
Black
White
Yellow
Yellow
Line
BALLAST
Black
White
Blue
Blue
Red
Red
Blue
BALLAST
Red
Red
LAMP
-
LAMP
LAMP
Diagram 1
DIAGRAM 1
Line
Use disconnect
lampholder only
Diagram 8
DIAGRAM 8
M
W
A
H
S
S
S
LAMP
LAMP
C
L
Black
B
L
M
H
M
L
D
Blue
White
Black
Black
BALLAST
W
H
W
BALLAST
M
L
Line
Line
Diagram 21
DIAGRAM
21
Diagram 22
DIAGRAM
22
3/32" Slots
E
Line
Black
White
Blue
BALLAST
Red
White
Yellow
LAMP
Mount lamp within 1/2" of
grounded metal reflector
DIAGRAM
Diagram 2828
PAGE 1-24
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
• 14-20 Watt
EXPORT
• Preheat/Trigger
High Output Lamps
• T12/T8
FOR 14 - 20 WATT, T8 AND T12 LAMPS
F14T12 - High Power Factor
2 Trigger 220/60Hz 567-L-TC
F15T12 - High Power Factor
2 Trigger 220/60Hz 567-L-TC
F15T8 - High Power Factor
2 Trigger 220/60Hz 567-L-TC
F20T12 - High Power Factor
2 Trigger 127/60Hz 597-L-TC-P❾
2 Trigger 220/60Hz 567-L-TC
Input
Power Ballast
(Watts) Factor
Line
Current
(Amps)
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
•
.22
44
.76
1.74
< 1.9
< 20
50/10
A
1
D2
•
.24
47
.85
1.81
< 1.9
< 20
50/10
A
1
D2
•
.25
49
.86
1.77
< 1.9
< 32
50/10
A
1
D2
•
•
•
.45
.26
55
53
.88
.83
1.60
1.55
< 1.7
< 1.7
< 15
< 20
50/10
50/10
A
A
1
1
D2
D2
❾ May also be used with F14T12, F15T8 and F15T12 Lamps
Overall Dimensions
Draw #
L
W
D2
9 1/2
2 3/8
Mounting Dimensions
H
M
X
1 1/2 8 57/64
1
WIRING DIAGRAMS
Line
H
BALLAST
Blue
Blue
Red
Red
LAMP
M
L
W
Black
White
Yellow
Yellow
LAMP
D
Diagram 1
DIAGRAM 1
PAGE 1-25
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electromagnetic
Lamp Certification
Line
Catalog
NOM
Qty. Descr.
Volts
Number
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
• 430-460 mA
EXPORT
• Rapid Start T12
High Output Lamps
FOR F30T12, F30T12ES, F40T12, F40T12/U,
F40T12ES AND F40T12ES/U LAMPS
Fluorescent-Electromagnetic
T8 U-Shaped Lamps
Lamp Certification
Line
Catalog
Qty. Descr.
Volts
Number NOM
F40T12 - High Power Factor
2 Rapid 120/60Hz 446-LR-TC-P➐
•
• •
2 Rapid 127/60Hz 595-L-TC-P❿
•
•
2 Rapid 220/60Hz 540-L-TC-P
•
2 Rapid 277/60Hz 808-BR-TC-P➐
•
•
•
F40T12/U - High Power Factor
1 Rapid 120/60Hz 412-L-TC-P➐
•
•
2 Rapid 120/60Hz 446-LR-TC-P➐
•
•
•
F40T12ES - High Power Factor
1 Rapid 120/60Hz 412-L-TC-P➐
•
•
2 Rapid 120/60Hz 446-LR-TC-P➐
•
•
•
2 Rapid 220/60Hz 540-L-TC-P
•
2 Rapid 277/60Hz 443-L-TC-P➐
•
•
•
F40T12ES/U - High Power Factor
2 Rapid 120/60Hz 446-LR-TC-P➐
•
•
•
❍ Power Factor Corrected to >80%
✜ Power Factor Corrected to >85%
➐ For Export Only-may not be purchased for use in the USA
For Distribution Only
Overall Dimensions
Draw #
L
W
D2
9 1/2
2 3/8
Mounting Dimensions
H
M
X
1 1/2 8 57/64
1
Line
Current
(Amps)
Input
Power Ballast
(Watts) Factor
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
.77
.70
.42
.36
91
87
90
96
.93
.88
.91
.94
1.02
1.01
1.01
0.97
<1.7
< 1.7
<1.7
< 1.7
<20
< 20
<20
< 20
50/10
50/10
50/10
50/10
A
A
A
A
1
1
1
1
D2
D2
D2
D2
.48
.77
57
91
.95
.91
1.67
1.00
< 1.7
< 1.7
< 20
< 20
60/15
50/10
A
A
42
1
D2
D2
.44
.66
.36
.32
51
75
75
82
.90
.86
.86
.88
1.76
1.15
1.15
1.08
< 1.7
< 1.9
<1.9
< 1.9
< 20
< 20
<20
< 20
50/10
60/15
60/15
60/15
A
A
A
A
42
1
1
1
D2
D2
D2
D2
.66
75
.86
1.15
< 1.9
< 20
60/15
A
1
D2
❿May also be used with F40T12ES Lamps
■For Replacement Only
✠For Distribution Only
WIRING DIAGRAMS
Line
Black
White
Yellow
Yellow
BALLAST
Blue
Blue
Red
Red
LAMP
H
LAMP
DIAGRAM
Diagram 1 1
M
L
W
D
Line
Black
White
Red
Red
BALLAST
Blue
Blue
LAMP
Diagram 4242
DIAGRAM
PAGE 1-26
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
• 430 mA
EXPORT
• Rapid Start
High Output Lamps
• Continuous Dimming
FOR F30T12 AND F40T12 LAMPS
Input
Power Ballast
(Watts) Factor
Line
Current
(Amps)
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
.85
.68
94
35
.88
.20
0.94
.57
< 1.7
< 1.7
< 20
< 32
50/10
50/10
A
A
18
18
D5
D5
.87
.58
83
27
.89
.21
1.07
.77
< 1.7
< 1.9
< 20
< 32
50/10
50/10
A
A
18
18
D5
D5
♠ Requires one circuit interrupting lamp holder
✝ Requires two circuit interrupting lamp holder
➑ UL component recognized for use with specific Dimming Controls
➁ Power Factor Corrected to <60%
➂ Power Factor Corrected to >60%
✠ For Distribution Only
Overall Dimensions
Draw #
L
W
D5
16 3/8 2 3/8
WIRING DIAGRAMS
Mounting Dimensions
H
M
X
1 1/2 15 25/32 1
DIMMER
Black
White
H
Blue/White
Blue
BALLAST
Brown
Yellow
Yellow
Red
Red
M
L
W
LAMP
D
Black
LAMP
White
Line
Use disconnect
lampholder only
Diagram
DIAGRAM
1818
Ballast must be grounded. Install in accordance with the national Electric Code
WARNING
External fuses should not be used with 277-volt dimming ballasts.
CAUTION
The control circuit line will carry approximately 0.375 amps per 40-watt lamps
(and approximately 0.41 amps per 30-watt lamp). This means that the control
circuit attached to the ballast brown wire must be sized appropriately. Please
note that the ampacity of the control line is approximately double the ampacity
requirement of the line when 277-volt dimming ballasts are used. When 120-volt
ballasts are used, the ampacity requirement of the control lead is slightly lower
than the line current.
PAGE 1-27
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electromagnetic
Lamp Certification
Line
Catalog
NOM
Qty. Descr.
Volts
Number
F40T12 - High Power Factor
2 @ 100% 120 502-A-TC-P✝➑✠
•
•
2 @ 20% 120 502-A-TC-P✝➑✠
•
•
F30T12 - Corrected Power Factor
2 @ 100% 120 502-A-TC-P➑➂✠
•
•
2 @ 20% 120 502-A-TC-P➑➁✠
•
•
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
• 425-440 mA
EXPORT
• 4´-8´ Lamp Applications
High Output Lamps
• T12 Slimline
• Instant Start
Fluorescent-Electromagnetic
Slimline Lamps
Lamp Certification
Line
Catalog
Qty. Descr.
Volts
Number NOM
F64T12 - High Power Factor
2 Instant 120/60Hz 806-BR-TC-P
•
•
F72T12 - High Power Factor
2 Instant 120/60Hz 806-BR-TC-P➐
•
•
2 Instant 220/60Hz 808-BR-TC-P❍
•
F84T12 - High Power Factor
2 Instant 120/60Hz 806-BR-TC-P➐
•
•
2 Instant 220/60Hz 808-BR-TC-P
•
F96T12 - High Power Factor
2 Instant 120/60Hz 806-BR-TC-P➐
•
•
2 Instant 220/60Hz 808-BR-TC-P✜
•
•
F96T12ES - High Power Factor
2 Instant 120/60Hz 806-BR-TC-P➐
•
•
2 Instant 220/60Hz 808-BR-TC-P◗
•
•
2 Instant 127/60Hz 831-TC
•
FOR F64, F72, F84, F96T12 AND F96T12ES LAMPS
Line
Current
(Amps)
Input
Power Ballast
(Watts) Factor
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
1.05
124
1.05
0.84
<1.85
<20
50/10
C
39
D12
1.15
.73
131
134
.90
.93
0.69
0.69
< 1.85 < 32
< 1.85 < 32
50/10
50/10
C
C
39
39
D12
D12
1.29
.77
149
152
.92
.95
0.62
0.63
< 1.85 < 32
< 1.85 < 32
50/10
50/10
C
C
39
39
D12
D12
1.40
.85
162
165
.89
.92
0.55
0.55
< 1.85 < 32
< 1.85 < 32
50/10
50/10
C
C
39
39
D12
D12
1.16
.76
1.07
129
130
124
.86
.86
.68
0.67
0.66
0.55
< 2.0 < 32
< 2.0 < 32
< 1.85 < 25
60/15
60/15
50/10
C
C
B
39
39
39
D12
D12
D10
◗ Power Factor Corrected to >75%
❍ Power Factor Corrected to >80%
✜ Power Factor Corrected to >85%
➐ For Export Only-may not be purchased for use in the USA
XFor Distribution Only
Overall Dimensions
Mounting Dimensions
Draw #
L
W
H
M
X
D10 9 29/64 3 3/32 1 25/32 8 57/64
1
11/16
WIRING DIAGRAMS
LAMP
Line
LAMP
White
H
Black
M
L
W
BALLAST
Red
Blue
Diagram 39
DIAGRAM
39
D
PAGE 1-28
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
• 430-460 mA
High
HighOutput
OutputLamps
Lamps
FOR F30T12, F30T12ES, F40T12, F40T12/U,
F40T12ES AND F40T12ES/U LAMPS
Slimline Lamps
T8 U-Shaped Lamps
❍ Power Factor Corrected to >80%
✜ Power Factor Corrected to >85%
➐ For Export Only-may not be purchased for use in the USA
For Distribution Only
Overall Dimensions
Draw #
L
W
D1
6 7/16 1 7/8
D2
9 1/2
2 3/8
Mounting Dimensions
H
M
X
1 1/2
6
1 1/2 8 57/64
1
Input
Power Ballast
(Watts) Factor
Line
Current
(Amps)
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Ballast
Efficacy Crest THD
Factor Factor
%
Dim.
.77
.70
.42
.36
91
87
90
96
.93
.88
.91
.94
1.02
1.01
1.01
0.97
<1.7
< 1.7
<1.7
< 1.7
<20
< 20
<20
< 20
50/10
50/10
50/10
50/10
A
A
A
A
1
1
1
1
D2
D2
D2
D2
.48
.77
57
91
.95
.91
1.67
1.00
< 1.7
< 1.7
< 20
< 20
60/15
50/10
A
A
42
1
D2
D2
.44
.66
.36
.32
51
75
75
82
.90
.86
.86
.88
1.76
1.15
1.15
1.08
< 1.7
< 1.9
<1.9
< 1.9
< 20
< 20
<20
< 20
50/10
60/15
60/15
60/15
A
A
A
A
42
1
1
1
D2
D2
D2
D2
.66
75
.86
1.15
< 1.9
< 20
60/15
A
1
D2
❿May also be used with F40T12ES Lamps
■For Replacement Only
✠For Distribution Only
WIRING DIAGRAMS
Line
Black
White
Yellow
Yellow
Blue
Blue
Red
Red
BALLAST
LAMP
H
LAMP
DIAGRAM
Diagram 1 1
M
L
W
Black/White
D
White
BALLAST
Blue
LAMP
Diagram 14
Line
DIAGRAM 14
PAGE 1-29
Red
Red
Line
Black
White
Red
Red
BALLAST
Blue
Blue
LAMP
Diagram 4242
DIAGRAM
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electromagnetic
Lamp Certification
Line
Catalog
Qty. Descr.
Volts
Number NOM
F40T12 - High Power Factor
2 Rapid 120/60Hz 446-LR-TC-P➐
•
• •
2 Rapid 127/60Hz 595-L-TC-P❿
•
•
2 Rapid 220/60Hz 540-L-TC-P
•
2 Rapid 277/60Hz 808-BR-TC-P➐
•
•
•
F40T12/U - High Power Factor
1 Rapid 120/60Hz 412-L-TC-P➐
•
•
2 Rapid 120/60Hz 446-LR-TC-P➐
•
•
•
F40T12ES - High Power Factor
1 Rapid 120/60Hz 412-L-TC-P➐
•
•
2 Rapid 120/60Hz 446-LR-TC-P➐
•
•
•
2 Rapid 220/60Hz 540-L-TC-P
•
2 Rapid 277/60Hz 443-L-TC-P➐
•
•
•
F40T12ES/U - High Power Factor
2 Rapid 120/60Hz 446-LR-TC-P➐
•
•
•
EXPORT
• Rapid Start T12
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
• 425-440 mA
EXPORT
• 4´-8´ Lamp Applications
High Output Lamps
• T12 Slimline
• Instant Start
Fluorescent-Electromagnetic
Slimline Lamps
Lamp Certification
Line
Catalog
Qty. Descr.
Volts
Number NOM
F64T12 - High Power Factor
2 Instant 120/60Hz 806-BR-TC-P
•
•
F72T12 - High Power Factor
2 Instant 120/60Hz 806-BR-TC-P➐
•
•
2 Instant 220/60Hz 808-BR-TC-P❍
•
F84T12 - High Power Factor
2 Instant 120/60Hz 806-BR-TC-P➐
•
•
2 Instant 220/60Hz 808-BR-TC-P
•
F96T12 - High Power Factor
2 Instant 120/60Hz 806-BR-TC-P➐
•
•
2 Instant 220/60Hz 808-BR-TC-P✜
•
•
F96T12ES - High Power Factor
2 Instant 120/60Hz 806-BR-TC-P➐
•
•
2 Instant 220/60Hz 808-BR-TC-P◗
•
•
2 Instant 127/60Hz 831-TC
•
FOR F64, F72, F84, F96T12 AND F96T12ES LAMPS
Line
Current
(Amps)
Input
Power Ballast
(Watts) Factor
Ballast
Efficacy Crest THD
Factor Factor
%
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Dim.
1.05
124
1.05
0.84
<1.85
<20
50/10
C
39
D12
1.15
.73
131
134
.90
.93
0.69
0.69
< 1.85 < 32
< 1.85 < 32
50/10
50/10
C
C
39
39
D12
D12
1.29
.77
149
152
.92
.95
0.62
0.63
< 1.85 < 32
< 1.85 < 32
50/10
50/10
C
C
39
39
D12
D12
1.40
.85
162
165
.89
.92
0.55
0.55
< 1.85 < 32
< 1.85 < 32
50/10
50/10
C
C
39
39
D12
D12
1.16
.76
1.07
129
130
124
.86
.86
.68
0.67
0.66
0.55
< 2.0 < 32
< 2.0 < 32
< 1.85 < 25
60/15
60/15
50/10
C
C
B
39
39
39
D12
D12
D10
◗ Power Factor Corrected to >75%
❍ Power Factor Corrected to >80%
✜ Power Factor Corrected to >85%
➐ For Export Only-may not be purchased for use in the USA
XFor Distribution Only
Overall Dimensions
Mounting Dimensions
Draw #
L
W
H
M
X
D6
11 3/4 3 1/8 1 25/32 11 9/64
2
D10 9 29/64 3 3/32 1 25/32 8 57/64
1
11/16
WIRING DIAGRAMS
LAMP
White
H
BALLAST
Black
M
L
W
Red
Line
Diagram 34
DIAGRAM
34
D
LAMP
Line
LAMP
White
Black
BALLAST
Red
Blue
Diagram 39
DIAGRAM
39
PAGE 1-30
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
UNIVERSAL®
ELECTROMAGNETIC
BALLASTS
• 430 mA
DIMMING
• Rapid Start
High Output Lamps
• Continuous Dimming
FOR F30T12 AND F40T12 LAMPS
Input
Power Ballast
(Watts) Factor
Line
Current
(Amps)
Min. F/C
Start Sound Wiring
Temp Rating Diag.
Ballast
Efficacy Crest THD
Factor Factor
%
Fluorescent-Electromagnetic
Lamp Certification
Line
Catalog
NOM
Qty. Descr.
Volts
Number
F40T12 - High Power Factor
2 @ 100% 120 502-A-TC-P✝➑✠
•
•
2 @ 20% 120 502-A-TC-P✝➑✠
•
•
2 @ 100% 277 678-A-TC-P✝➑✠
•
•
2 @ 20% 277 678-A-TC-P✝➑✠
•
•
F30T12 - Corrected Power Factor
2 @ 100% 120 502-A-TC-P➑➂✠
•
•
2 @ 20% 120 502-A-TC-P➑➁✠
•
•
2 @ 100% 277 678-A-TC-P➑➂✠
•
•
2 @ 20% 277 678-A-TC-P✝➑➁✠
•
•
Dim.
.85
.68
.39
.34
94
35
100
30
.88
.20
.88
.20
0.94
.57
0.94
.67
< 1.7
< 1.7
< 1.7
< 1.7
< 20
< 32
< 32
< 32
50/10
50/10
50/10
50/10
A
A
A
A
18
18
16
16
D5
D5
D5
D5
.87
.58
.85
.68
83
27
96
33
.89
.21
.90
.23
1.07
.77
0.93
.70
< 1.7
< 1.9
< 1.7
< 1.7
< 20
< 32
< 32
< 32
50/10
50/10
50/10
50/10
A
A
A
A
18
18
16
16
D5
D5
D5
D5
♠ Requires one circuit interrupting lamp holder
✝ Requires two circuit interrupting lamp holder
➑ UL component recognized for use with specific Dimming Controls
➁ Power Factor Corrected to <60%
➂ Power Factor Corrected to >60%
✠ For Distribution Only
Overall Dimensions
Draw #
L
W
D2
9 1/2
2 3/8
11/16
WIRING DIAGRAMS
Mounting Dimensions
H
M
X
1 1/2 8 57/64
1
DIMMER
DIMMER
Black/White
White
H
Black
White
Red/White
Blue/White
Blue
Red/White
Line
BALLAST
Blue
Red
Red
BALLAST
Red
M
L
W
Brown
Yellow
Yellow
Red
LAMP
LAMP
D
LAMP
Use disconnect
lampholder only
Line
Use disconnect
lampholder only
Diagram 9
DIAGRAM 9
WARNING
External fuses should not be used with 277-volt dimming ballasts.
Diagram 16 16
DIAGRAM
DIMMER
Black
White
Blue/White
Blue
BALLAST
Black
White
Blue/White
Blue/White
Blue
Yellow
Yellow
Red
Red
LAMP
White
Line
Use disconnect
lampholder only
Diagram 18
Ballast must be grounded. Install in accordance with the national Electric Code
PAGE 1-31
DIAGRAM 18
BALLAST
Brown
Red
Red
LAMP
LAMP
Black
CAUTION
The control circuit line will carry approximately 0.375 amps per 40-watt lamps
(and approximately 0.41 amps per 30-watt lamp). This means that the control
circuit attached to the ballast brown wire must be sized appropriately. Please
note that the ampacity of the control line is approximately double the ampacity
requirement of the line when 277-volt dimming ballasts are used. When 120-volt
ballasts are used, the ampacity requirement of the control lead is slightly lower
than the line current.
DIMMER
Brown
Line
Use disconnect
lampholder only
Diagram 19
DIAGRAM 19
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Electronic
Fluorescent Ballasts
A Complete Range of
Solutions — From The
Name You Trust
For more than 30 years, the lighting industry has
relied on our TRIAD® brand for the most specified,
most installed, most reliable electronic ballasts in the
business.
The TRIAD® line offers advantages like installerfriendly universal input voltage, which ensures that
you have the right voltage ballast every time. We’re
also the industry leader in low profile design lightweight, space-saving ballasts that offer the same
footprint and wiring as conventional ballasts. And our
AccuStart™ ballasts feature programmed rapid start
technology that dramatically enhances lamp life.
Universal Lighting Technologies is a subsidiary of
Panasonic Electric Works Co., Ltd., a member of the Panasonic Group
Fluorescent-Electronic
Fluorescent-Electronic
Universal is the leader in energy saving electronic ballasts.
Product Overview
Setting The Pace In T8 Technology
Universal Lighting keeps pushing the frontier of T8 technology with innovative products that deliver
dramatic energy savings, greater fixture design flexibility, longer lamp life and installation ease. You
can count on Universal for some of the industry’s smallest, lightest and most hassle-free T8 ballasts.
Universal Voltage Low Profile High Performance (HP-A and HP-B)
Our low profile High Performance ballasts with THD<10% offer the convenience of universal input voltage (108 - 305 volts) as a standard feature. Universal input is “installer-friendly” - ensuring that you
have the right voltage ballast every time. Our low profile models also feature a remarkably small package and cross section (1.0”H x 1.5”W) for greater flexibility in fixture design. Since the mounting and
wiring footprints are the same as a standard size ballast, our low profile HP models will easily retrofit
into any T12 or T8 fixture.
High Efficiency Lamp/Ballast System
The High Efficiency Lamp/Ballast System is the most significant advancement in linear fluorescent
energy savings in more than a quarter century. The system delivers up to 40% energy savings
compared to conventional magnetic T12 energy-saving systems and up to 11% versus standard
electronic T8 systems. Our High Efficiency ballast is designed to operate any lamp manufacturer’s
F32T8/ES energy-saving lamp or standard F32T8 lamp. There are two options:
- EL suffix denotes .77 ballast factor
- HE suffix denotes .87 ballast factor
- HEH suffix denotes 1.18 ballast factor
AccuStart®
AccuStart® ballasts are ideal for frequently switched applications or as a rapid start alternative. They incorporate programmed rapid start technology to properly heat the lamp filaments, which yields an increase in
lamp life up to 50%. The 1-4 lamp models offer universal input voltage - an industry exclusive.
Fluorescent-Electronic
T8 Super Low Profile
Our T8 super low profile models offer maximum fixture flexibility. They’re ideal for pendant mount and
other specialty lighting applications. They feature a small cross section (1.0”H x 1.18”W) and low profile dimensions for indirect/direct fixtures, plus installer-friendly universal input voltage
(108 - 305 volts).
Low Power (L-A)
Family of Low Profile Ballasts.
AccuStart® ballasts for frequently switched applications.
PAGE 2-2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Product Overview
Low Power (L-A)
The L-A Series ballasts offer the option of a .78 ballast factor for maximum energy savings. They
feature space-saving low profile design. The 2- to 4-lamp models are ideal for retrofitting energysaving T12 lamps - and offer parallel lamp operation and THD<20%.
Low Profile Reduced Harmonic (RH-A)
Our low profile RH ballasts are over 45% smaller and 30% lighter. They feature a space-saving package and cross section (1.18” H x 1.7”W) for greater flexibility in fixture design. The 1- to 4-lamp
model features parallel lamp operation, with standard mounting footprint and wiring for ease of
replacement. They offer high efficiency performance with THD<20%.
Reduced Harmonic High Output (RHH and RHH-A)
These ballasts deliver the maximum light output by operating lamps at their rated current of 265mA
without compromising lamp life. They feature a 1.18 ballast factor versus the industry standard .88
to provide lighting design flexibility.
T5 Ballasts For Indirect And High-End Architectural Applications
T5 systems are gaining greater popularity for high-end architectural applications. Universal Lighting
gives you a wide range of T5 solutions, from 14 to 54 watts. Our T5 ballasts operate multiple (1 or
2) F35T5, F28T5, F21T5 and F14T5 lamps. Additionally, our T5HO ballasts operate multiple (1 or 2)
F54T5HO, F39T5HO and F24T5HO lamps. Moreover, they make your life easier with standard features
that include universal input voltage (108 - 305 volts), programmed rapid start technology for longer
lamp life and end of lamp life shutdown circuit with auto-reset.
T5 Standard Output
Our standard output T5 ballasts support multiple lamp operation (including 14-, 21-, 28-, and
35-watt lamps). They’re ideal for indirect pendant mount, surface mount, cove, undercabinet or task
lighting. With a small cross section (1.0”H x 1.18”W), our T5 models give you more options for slim
fixture design. Standard features include universal input voltage, end-of-lamp-life shutdown circuit
and programmed rapid start technology.
T5 High Output
Universal’s high output T5 ballasts support 24-, 39- and 54-watt lamps. They offer the same
standard features and compact dimensions as our T5 standard output line - and they’re also wellsuited to applications where space is at a premium, including slim pendant mounted fixtures, cove
and task lighting.
Fluorescent-Electronic
Family of Universal HP Ballasts.
Flexible Fixture design options for T5 and T5HO lamps.
PAGE 2-3
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
SAFETY
NEC & UL Requirements
Ballast installation presents the possibility of exposure to potentially hazardous voltages and should be performed only by qualified
personnel. All installation, inspection and maintenance should be performed only with power to the fixture turned off. Additionally, all
fixtures and ballasts must be installed and operated in compliance with the National Electrical Code, Underwriters Laboratories Inc. (UL)
requirements, and all local applicable codes and regulations.
Polarity
Polarity refers to the proper connection of ballast lead wires to line wires. To aid you in making a correct installation, Universal ballast leads are color-coded for easy identification. The WHITE ballast lead is to be connected to the neutral (grounded) and the BLACK
(or black with white tracer) lead always to the phase (“hot”) line wire. Systems where neither of the line wires are at ground potential
require specially designed ballasts. A change in polarity may result in the voltage from the lead to the ground exceeding UL-specified
limits. In some types of ballasts, a change in polarity may decrease voltage from the lead to the ground, thereby impeding the starting
dependability of the ballast.
Grounding
Ballast cases and fixtures must always be grounded. The ballast case may be grounded to the fixture or otherwise grounded. It could be
hazardous to make contact with an ungrounded fixture or ballast when in operation. Neglecting to properly ground the ballast and fixture combination may also result in failure of certain lamps to start or for unacceptable levels of electromagnetic noise to be conducted
onto the power lines.
Operating Line Voltage Limits
To receive the full benefits of rated lamp output and to prolong ballast life, it is essential that voltage supplied to an installation be maintained within limits prescribed for each circuit. These limits are listed below:
Nominal Voltage
Minimum
VOLTAGE RANGE
Maximum
120
220
277
347
120-277 (UNV)
347-480 (HRV)
108
198
249
312
108
312
132
242
305
382
305
528
Fluorescent-Electronic
Subjecting a ballast to excessive voltage for an extended period results in the deterioration of the insulation. This insulation breakdown will cause early ballast failure.
Low voltage has no damaging effect on the ballast. However, lamps may not start reliably, and early lamp failure could result.
Internal Ballast Protection
Class P Classification - Since January 1, 1984, the National Electrical Code requires that “where Fluorescent fixtures are installed
indoors, the ballast shall have thermal protection integral within the ballast except for simple reactance ballasts.” This ruling applies to
replacement ballasts as well as to those contained within new fixtures.
In compliance with the National Electrical Code, UL has established a Class P ballast classification for fluorescent light fixtures.
A Class P ballast must employ internal thermal protection limiting its operating temperature.
Universal UL-approved Class P ballasts comply with the National Electrical Code requirement and are equipped with an automatic resetting thermal protector, built-in and adjacent to the transformer coils. The resetting thermal protector functions as a thermostat which
will open and temporarily deactivate the ballast when it exceeds the permissible temperature. It will reset when the ballast cools to a
safe operating temperature. The ballast will continue to cycle until the cause of overheating is eliminated. If the ballast is defective, it
must be replaced. If the cause is external, a Class P ballast will resume normal operation after abnormal conditions are eliminated.
PAGE 2-4
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
SAFETY
Dimming Ballasts - Ballastar® Dimming Ballasts are controlled by using 10-0vDC. Care should be taken to insure that the line
voltage (AC) wires are not connected to the low voltage DC wires. Ballastar® Electronic Dimming Ballasts have protection (safety)
circuitry, that will sense the error so as not to harm the installer or the ballast. Dimming ballasts manufactured after May 1999 have
the protection circuit. Dimming ballasts manufactured before this date do not have low voltage circuit protection.
Fusing - Class P ballasts do not require fusing. Fusing can be used when a single circuit has a large number of fixtures/ballasts.
For a comprehensive list of appropriate fuses, contact our Technical Engineering Services (TES) Department at 1-800-BALLAST
or check out our TES home page at www.unvlt.com.
Grounding - ANSI C82.1 recommends all fixtures and ballasts be grounded. Universal requires all electronic ballasts be grounded.
Thermal Protection - All Universal electronic ballasts meet UL 935 Standard for thermal protection. These ballasts are designated
Class P. A Class P ballast will disconnect the ballast from input power in the event of internal over-temperature.
PERFORMACE
Lamp Connections
Fluorescent ballasts are designed to generate voltages in excess of 300 volts. It is imperative that proper connection to quality sockets
be assured in accordance with wiring diagrams on each page of the catalog and on product labels. Some applications may not require
the use of all of the ballast output leads. If any leads are not to be connected, each should be individually capped and insulated to at
least 600 volts.
Application Versatility
Many Universal models are designed to allow for applications with different types or quantities of lamps. Lamp applications not listed
on label cannot be warranted.
Audible Noise (Sound)
Electrical equipment, including most fluorescent lamp ballasts, produces some noise. Care must be taken to select a ballast with the
proper sound rating for a particular lighting installation. Secure mounting can reduce the potential for audible noise. Typically, electronic ballasts operate up to 75% quieter than electromagnetic ballasts for fluorescent lamps.
EMI/RFI
Electronic ballasts operate at high frequency and, therefore, may produce radio frequency interference (RFI) or electromagnetic interference (EMI). Some sensitive electrical equipment such as televisions, radios, or some medical equipment can be adversely affected by this
RFI or EMI interference. Currently the electronic frequencies from 450 kilohertz (kHz) to 300 megahertz (MHz) are regulated by the FCC. For
electronic ballasts, the limits and regulations are listed in the Code of Federal Regulations, Title 47, Part 18, Subpart C titled RF Lighting
Devices. ULT provides ballasts compliant with non-consumer limits for commercial applications,
as well as several models in compliance with consumer limits for residential use.
See the Data Sheets for the electronic ballast of interest to determine which FCC requirement, consumer or non-consumer
the particular product meets.
PAGE 2-5
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Remote Mounting
Excessive hot or cold temperatures, audible noise requirements, or a desire to operate lamps in more than one fixture with the same
ballast (master/slave), may make it desirable to mount the ballast remotely. Care must be taken to allow for ballast heat dissipation and
proper grounding.
In any application, the wire used to extend leads must be at least as large as the wire supplied on the ballast (18 AWG) with an insulation rating of 1000 VAC at 90°C.
Lead lengths in excess of those noted cause loading effects that can dramatically impact ballast performance and void the warranty.
Universal T8 Instant Start and Programmed Rapid Start Electronic ballasts can be mounted remotely, from the lamp sockets, up to 18 feet.
Universal T8 Rapid Start Electronic ballasts can be mounted remotely, from the lamp sockets, up to 12 feet.
Application And Operating Information
PERFORMANCE
• Lamp Starting Dependability
Fluorescent lamps are inherently more difficult to start at low temperatures. All ballasts have limitations
as to their ability to start lamps at low ambient temperatures. In this catalog, the low starting point for
each lamp/ballast combination appears in the column marked “Minimum Starting Temperature.”
Universal four lamp instant start ballasts can operate at a minimum starting temperature down to -18°C (0°F)
under the following conditions:
1. Lead lengths to the lamps are those supplied, by Universal, with the ballast or shorter.
2. The distance from the lamp to the ground plane is no greater than 3/4”.
3. The line voltage supplied to the ballast is no less than rated nominal.
4. The ballast or lamps are not remotely mounted.
5. The lamps have been burned in per lamp manufacturer requirements (typically 100 hours).
The lamp manufacturer should be contacted for lamp operating characteristics and requirments below 15°C (50°F).
• Light Output
Optimum light output from fluorescent lamps is achieved when the lamp wall is at 100-110°F.
Any substantial excursion (either colder or warmer) will result in a reduction in light output.
• Ballast Life
A fluorescent lamp ballast, like any other electrical device, generates heat during its normal operation.
Ballast temperatures should be kept as low as possible. Maximum dissipation of heat through fixture
design and proper ballast installation will help. Although excessive temperature may not cause the
ballast to fail immediately, it can shorten ballast life. To assure maximum life, the ballast case temperature
should not exceed 75˚C, in a maximum ambient (fixture cavity) of 40˚C.
Causes of ballast overheating:
• Incorrect line voltage or frequency
• Incorrect size, type or number of lamps
• Incorrect wiring
• Poor heat dissipation due to surrounding insulation
• Sealed (Vapor Tight) Fixtures - Unusual heat build-up due to lack of ventilation in
fixtures may cause thermal (on/off) cycling of certain ballasts. Consult Universal for
specific recommendations.
Fluorescent-Electronic
RECOMMENDATIONS...
• Selection of a proper ballast to match the requirements of the lamp,
fixture, voltage and installation.
•
Mounting of ballast within the fixture with as much surface contact
as possible between the ballast and metal portions of the fixture.
Secure mounting will aid in proper heat dissipation and can minimize
the potential for ballast hum.
• The use of heat-conducting dissipators (radiators), if necessary,
which increase surface contact between the ballast and fixture.
• If necessary, locate the ballast in a remote, cooler area outside the fixture.
• Consult Universal for remote mounting recommendations.
• Starting Method Legend
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
PAGE 2-6
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Specifications
TYPICAL SPECIFICATIONS
FOR INSTANT START BALLASTS FOR:
Ballasts (1-4 lamp) shall operate as a Parallel Circuit, allowing remaining lamp(s) to maintain full light output
if one or more lamps fail.
Ballasts shall operate from 60 Hz input source of 120, 277 Volts, and sustained variations of
± 10% (Voltage & Frequency) with no damage to the ballasts.
Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz.
Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp
manufacturer recommendation and ANSI C82.11-1993.
Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and
RFI (Radiated).
Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2.
Ballasts shall operate lamps with no visible flicker (<3% flicker index).
Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage.
Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified
where applicable.
Ballast shall have a Ballast Factor greater than .85 per ANSI C82.11-1993.
- Ballast Factor for Low Power (L-A) models shall be greater than .77.
Input current Total Harmonic Distortion shall not exceed 20% for the primary lamp applications
Ballasts shall have a Power Factor greater than .95 for primary lamp applications.
The ballasts do not contain any PCB’s.
The manufacturer shall provide written warranty against defects in material or workmanship, including
replacement, for five years from date of manufacture.
Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years.
Ballast shall be manufactured in an ISO 9001 Certified Facility
Ballasts shall provide instant starting sequence consistent with ANSI standard C82.11-1993.
Universal model ______________ (or approved equal).
PAGE 2-7
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
• RH (Reduced Harmonic)
• L (Low Wattage)
• RHH and RHH-A (Reduced Harmonic High Output)
Specifications
Fluorescent-Electronic
TYPICAL SPECIFICATIONS
FOR INSTANT START BALLASTS FOR:
Universal Voltage
• HP (High Performance)
1. Ballasts (1-4 lamp) shall operate as a Parallel Circuit, allowing remaining lamp(s) to maintain full light output
if one or more lamps fail.
2. Ballasts shall operate from 50/60 Hz input source of 120 through 277 Volts, and sustained variations of
± 10% (Voltage & Frequency) with no damage to the ballasts.
3. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 42 kHz to
minimize interference with infared control systems.
4. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp
manufacturer recommendation and ANSI C82.11-1993.
5. Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and
RFI (Radiated).
6. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2.
7. Ballasts shall operate lamps with no visible flicker (<3% flicker index).
8. Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage.
9. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified
where applicable.
10. Ballast shall have a Ballast Factor greater than .85 per ANSI C82.11-1993.
11. Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp.
12. Ballasts shall have a Power Factor greater than .98 for primary lamp.
13. The ballasts shall not have any PCB’s.
14. The manufacturer shall provide written warranty against defects in material or workmanship, including
replacement, for five years from date of manufacture.
15. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years.
16. Ballast shall be manufactured in an ISO 9001 Certified Facility.
17. Ballasts shall provide instant starting sequence consistent with ANSI standard C82.11-1993.
18. Ballast shall be Universal Lighting Technologies Bx32IUNVHP-B (x=1 or 2) or Bx32IUNVHP-A (x=3 or 4)
depending upon the quantity of lamps per fixture.
19. Universal model ______________ (or approved equal).
PAGE 2-8
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Specifications
TYPICAL SPECIFICATIONS
FOR INSTANT START BALLASTS FOR:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
• HP (High Performance)
• HPL (High Performance Low Power)
• HPH (High Performance High Light)
Ballasts (1-4 lamp) shall operate as a Parallel Circuit, allowing remaining lamp(s) to maintain full light output
if one or more lamps fail (except T12 High Output).
Ballasts shall operate from 50/60 Hz input source of 120, 277, and 347 Volts, and sustained variations of
± 10% (Voltage & Frequency) with no damage to the ballasts.
Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz.
Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp
manufacturer recommendation and ANSI C82.11-1993.
Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2.
Ballasts shall operate lamps with no visible flicker (<3% flicker index).
Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage.
Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified
where applicable.
Ballast shall have a Ballast Factor greater than .85 per ANSI C82.11-1993.
- Ballast Factor for Low Power (L) models shall be greater than .77.
Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp.
Ballasts shall have a Power Factor greater than .98 for primary lamp.
The ballasts do not contain any PCB’s.
The manufacturer shall provide written warranty against defects in material or workmanship, including
replacement, for five years from date of manufacture.
Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years.
Ballast shall be manufactured in an ISO 9001 Certified Facility
Ballasts shall provide instant starting sequence consistent with ANSI standard C82.11-1993.
Universal model ______________ (or approved equal).
Fluorescent-Electronic
PAGE 2-9
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Specifications
TYPICAL SPECIFICATIONS
FOR RAPID START BALLASTS
Ballasts (1-4 lamp) shall operate as a Parallel Circuit, allowing remaining lamps(s) to maintain full light output
if one or more lamps fail (except T12 High Output).
Ballasts shall operate from 60 Hz input source of 120, 277 Volts, and sustained variations of
± 10% (Voltage & Frequency) with no damage to the ballasts.
Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz.
Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp
manufacturer recommendation and ANSI C82.11-1993.
Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and
RFI (Radiated).
Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2.
Ballasts shall operate lamps with no visible flicker (<3% flicker index).
Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage.
Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, CSA Certified
where applicable.
Ballast shall have a Ballast factor greater than .85, per ANSI C82.11-1993.
Input current Total Harmonic Distortion shall not exceed 10% for primary lamp applications.
Ballast shall be manufactured in an ISO 9001 Certified Facility
Ballasts shall have a Power Factor greater than 0.98 primary applications.
The ballasts do not contain any PCB’s.
The manufacturer shall provide written warranty against defects in material or workmanship, including
replacement, for five years from date of manufacture.
Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years.
Ballasts shall provide rapid starting sequence consistent with ANSI standard C82.11-1993.
Universal model ______________ (or approved equal).
Fluorescent-Electronic
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
PAGE 2-10
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Specifications
TYPICAL SPECIFICATIONS
FOR PROGRAMMED RAPID START BALLASTS:
1. Ballasts shall have a minimum start temperature of 0°F.
2. Ballasts shall operate from a 50/60 Hz input source of 120 through 277 Volts, and sustained variations of
± 10% (Voltage & Frequency) with no damage to the ballasts.
3. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 42 kHz to minimize
interference with infrared control systems.
4. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp
manufacturer recommendation and ANSI C82.11-1993.
5. Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and
RFI (Radiated).
6. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2.
7. Ballasts shall operate lamps with no visible flicker (<3% flicker index).
8. Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage.
9. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified
where applicable.
10. Ballast shall have a Ballast factor greater than .85, per ANSI C82.11-1993.
11. Input current Total Harmonic Distortion shall not exceed 10%.
12. Ballasts shall have a Power Factor greater than 0.98, for primary application.
13. The ballasts shall not have any PCB’s.
14. The manufacturer shall provide written warranty against defects in material or workmanship, including
replacement, for five years from date of manufacture.
15. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years.
16. Ballast shall be manufactured in an ISO 9001 Certified Facility.
17. Ballast shall be manufactured in North America.
18. Ballast shall be Universal Lighting Technologies AccuStart HP Product Bx32PUNVHP-A (x=1,2,3. or 4).
19. Universal model ______________ (or approved equal).
Fluorescent-Electronic
PAGE 2-11
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Specifications
TYPICAL SPECIFICATIONS
FOR INSTANT START T5 AND T5 HIGH OUTPUT (HO) BALLASTS :
Fluorescent-Electronic
1. Ballast shall be Instant Start.
2. Ballast shall incorporate lamp shutdown circuitry for end of lamp life protection.
3. Ballast shall allow for re-lamping without the need to cycle power.
4. Ballasts shall operate from 50/60 Hz input source from 108-305 Volts with no damage to the ballasts.
5. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz.
6. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp
manufacturer recommendation and ANSI C82.11-1993.
7. Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and
RFI (Radiated).
8. Ballasts shall provide transient immunity recommended by ANSI C62.41-1991, Location A2.
9. Ballasts shall operate lamps with no visible flicker (<3% flicker index).
10. Ballasts shall tolerate sustained open and short circuit output conditions without damage.
11. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified
where applicable.
12. Ballast shall have a Ballast Factor greater than 0.95 per ANSI C82.11-1993.
13. Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp.
14. Ballasts shall have a Power Factor greater than .98.
15. The ballasts do not contain any PCB’s.
16. The manufacturer shall provide written warranty against defects in material or workmanship, including
replacement, for up to five years from date of manufacture.
17. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years.
18. Ballast shall be manufactured in an ISO 9001 Certified Facility.
19. Universal model ______________ (or approved equal).
PAGE 2-12
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Specifications
TYPICAL SPECIFICATIONS
FOR PROGRAMMED RAPID START T5 AND T5 HIGH OUTPUT (HO) BALLASTS :
1. Ballast shall be Programmed Rapid Start.
2. Ballast shall incorporate lamp shutdown circuitry for end of lamp life protection.
3. Ballast shall allow for re-lamping without the need to cycle power.
4. Ballasts shall operate from 50/60 Hz input source from 108-305 Volts with no damage to the ballasts.
5. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz.
6. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp
manufacturer recommendation and ANSI C82.11-1993.
7. Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and
RFI (Radiated).
8. Ballasts shall provide transient immunity recommended by ANSI C62.41-1991, Location A2.
9. Ballasts shall operate lamps with no visible flicker (<3% flicker index).
10. Ballasts shall tolerate sustained open and short circuit output conditions without damage.
11. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified
where applicable.
12. Ballast shall have a Ballast Factor greater than 0.95 per ANSI C82.11-1993.
13. Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp.
14. Ballasts shall have a Power Factor greater than .98.
15. The ballasts do not contain any PCB’s.
16. The manufacturer shall provide written warranty against defects in material or workmanship, including
replacement, for up to five years from date of manufacture.
17. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years.
18. Ballast shall be manufactured in an ISO 9001 Certified Facility.
19. Universal model ______________ (or approved equal).
Fluorescent-Electronic
PAGE 2-13
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
F17T8
• Low Profile
Designs Featured
TRIAD® ELECTRONIC BALLASTS
FOR (1) & (2)
F17T8 LAMP
• Instant & Programmed
Rapid Starting Options
Fluorescent-Electronic
• 1-2 Lamp Applications
Lamp Certification
Line
Input Power
Starting
Line
Catalog Current Power Factor
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF)
F17T8 - One Lamp Application
120 B132I120RH-A
•
•
•
0.17
19 > .90
277 B132I277RH-A
•
•
0.07
20 > .90
347 B132I347RH
•
0.05
18 > .95
120
0.14
B132IUNVHP-B •
•
17 >.95
277
0.07
1
347 B132I347HP
•
0.05
18 > .95
IS
120 B232I120RES-A* •
•
•
0.35
21 > .50
120 B232I120RES-G* •
•
•
0.34
22 > .50
120
0.17
> .98
B232IUNV-C
•
•
20
277
0.08
> .95
120
0.12
> .98
B132IUNVEL-A •
•
14
277
0.06
> .90
120
0.13
> .98
B132IUNVHE-A •
•
16
277
0.07
> .90
120
0.14
16
ES1608A
•
•
> .97
277
0.07
17
120
0.15
> .99
B132PUNVHP-A •
•
•
17
1
PRS
277
0.07
> .96
347 ES1510A
•
0.05
18 > .97
F17T8 - Two Lamp Applications
120 B232I120L-A
•
•
0.27
30 > .90
277 B232I277L-A
•
•
0.12
30 > .90
347 B232I347L-A
•
0.09
29 > .98
120 B232I120RES-G* •
•
•
0.49
33 > .50
120 B232I120RES-A* •
•
•
0.49
32 > .50
120 B232I120RH-A
•
•
•
0.31
34 > .90
277 B232I277RH-A
•
•
•
0.13
34 > .90
347 B232I347RH-A
•
0.09
32 > .95
2 PAR-IS 347 B232I347HPL
•
0.09
29 > .98
120
0.26
> .99
B232IUNVHP-B •
•
•
32
277
0.12
> .98
347 B232I347HP-A
•
0.09
32 > .95
120
0.27
> .99
B232IUNV-C
•
•
31
277
0.12
> .98
120
0.21
25
B232IUNVEL-A •
•
> .95
277
0.10
26
120 B232I120EL
•
•
0.22
26 > .98
277 B232I277EL
•
•
0.11
27 > .98
120
0.24
B232IUNVHE-A •
•
30 > .95
277
0.12
120
0.33
41
B232IUNVHEH-A •
•
> .95
277
0.15
40
120 B232I120HE
•
•
0.25
30 > .98
277 B232I277HE
•
•
0.12
30 > .95
120
0.24
29
2 SER-IS
ES1608A
•
•
> .97
277
0.11
30
120
0.22
26
B232PUNVEL-A •
> .90
277
0.10
26
120
0.24
29
B232PUNVHE-A •
> .90
277
0.11
28
2 SER-PRS 120
0.29
35
ES4800A
•
•
> .97
277
0.13
36
120
0.28
> .99
B232PUNVHP-A •
•
•
34
277
0.13
> .95
347 ES1329A
•
•
0.11
36 > .97
* For Residential Use Only
Ballast
Ballast
Min. F/C
Factor Efficacy THD Start Wiring
(BF) Factor (BEF) %
Temp Diag. Dim.
0.93
0.93
0.92
< 32
< 32
< 20
< 10
< 15
< 15
< 150
< 150
0/-18
0/-18
0/-18
1
1
1
0/-18
0/-18
0/-18
0/-18
1
1
3a
3a
1.04
4.89
4.65
5.11
5.24
5.11
5.14
4.91
5.20
< 10
0/-18
21a
0.78
5.57
< 15
0/-18
1
-A
0.90
5.63
< 10
0/-18
1
-A
0.87
5.44
5.12
5.35
4.83
< 10
0/-18
39a ESA
< 10
< 15
< 10
0/-18
0/-18
2
40
0.89
0.92
1.08
1.08
0.91
0.87
0.85
0.86
0.80
0.94
0.94
0.95
0.95
0.92
0.79
-A
-A
ST
-B
ST
-A
-G
-C
-A
ESA
< 32
< 32
< 20
< 140
< 140
< 32
< 32
< 20
< 10
< 10
< 10
< 10
< 10
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
3
3
3
3
3
3
3
3
3
0/-18
0/-18
3
3
0.91
0.80
0.79
0.80
2.83
2.87
2.76
2.85
2.94
2.79
2.79
2.88
2.72
2.84
2.88
2.94
3.20
3.08
3.04
2.96
0/-18
21
-C
< 10
0/-18
3
-A
<10
<15
0/-18
0/-18
3
3
ST
ST
0.90
3.00
< 10
0/-18
3
-A
1.18
0.91
0.91
0.87
0.72
0.84
0.95
2.88
2.95
3.03
3.03
3.00
2.90
2.77
2.77
2.90
3.00
2.71
2.64
2.79
2.42
< 10
0/-18
3
-A
<10
<10
0/-18
0/-18
3
3
ST
ST
< 10
0/-18
39
ESA
< 10
0/-18
30
-A
< 10
0/-18
30
-A
< 10
0/-18
37
ESA
< 10
< 15
<10
0/-18
0/-18
30
37
-A
0.91
0.92
0.95
0.87
-A
-A
-A
-G
-A
-A
-A
-A
ST
-B
-A
ESA
See page 2-18 for Dimensions and Wiring Diagrams
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
SER-PRS = Series Programmed Rapid Start
PAGE 2-14
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
SER-IS = Series Instant Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (3) & (4) F17T8 LAMPS
F17T8
• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
• 3-4 Lamp Applications
* For Residential Use Only
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
0.40
0.17
0.12
0.47
0.20
0.14
0.12
0.38
0.18
0.14
0.35
0.15
0.32
0.15
0.39
0.17
0.36
0.17
0.49
0.22
0.72
0.41
0.18
0.39
0.18
0.41
0.19
44
44
43
52
52
47
43
45
48
42
41
38
40
46
43
44
60
58
51
49
48
46
47
49
48
0.48
0.21
0.17
0.84
0.54
0.23
0.19
0.17
0.49
0.22
0.19
0.49
0.22
0.44
0.20
0.42
0.22
0.49
0.22
0.47
0.22
0.28
0.48
0.23
0.53
0.24
55
54
56
61
63
61
64
56
59
58
62
59
58
53
52
51
51
59
58
56
58
77
57
58
63
62
>.90
>.95
>.99
> .90
> .90
> .95
> .99
> .99
> .90
> .98
> .99
> .95
>.98
>.98
> .99
> .97
>.98
>.95
0.86
0.88
0.80
0.99
0.99
0.90
0.80
0.92
0.92
0.82
0.79
0.80
> .95
> .50
> .98
> .95
1.19
1.00
0.99
0.87
> .97
> .99
> .90
> .95
> .95
> .97
> .50
> .95
> .95
> .95
> .97
> .98
> .90
> .98
> .98
> .95
> .98
> .95
> .98
> .98
> .98
> .95
> .98
> .98
> .99
> .97
> .99
> .90
0.92
0.89
0.91
0.93
0.79
0.80
0.82
0.92
0.92
0.92
0.92
0.82
0.90
0.92
0.91
0.79
0.81
0.80
0.90
0.91
0.91
1.20
0.87
0.91
1.95
2.00
1.85
1.90
1.90
1.91
1.85
2.04
1.92
1.95
2.00
2.08
2.00
<30
<25
<20
< 32
< 32
< 20
< 10
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
6
6
6
6
6
6
6
-A
-A
ST
-A
-A
ST
ST
< 10
< 10
0/-18
0/-18
6
-A
6
ST
2.00
< 10
0/-18
6
-A
2.07
2.07
1.98
2.05
1.96
1.98
2.02
1.89
1.85
1.90
1.94
<10
<10
0/-18
0/-18
6
6
ST
ST
< 10 0/-18
< 135 0/-18
< 10
0/-18
< 12
6
7a
-A
-A
24
-D
1.44
1.48
1.46
1.51
1.46
1.51
1.44
1.46
1.53
1.55
1.48
1.51
1.56
1.49
1.52
1.59
1.57
1.53
1.55
1.63
1.57
1.56
1.53
1.50
1.44
1.47
< 10
0/-18
6
-A
<10
<15
0/-18
0/-18
6
6
ST
ST
< 10
0/-18
38a ESB
< 10
0/-18
23
-A
< 20
< 20
< 20
< 130
< 20
< 20
< 20
< 10
< 10
< 10
< 10
< 12
0/-18
0/-18
0-/18
0/-18
0/-18
0/-18
0/-18
0/-18
7a
7a
7
7a
7a
7a
7a
7
-A
-A
ST
-A
-A
-A
ST
ST
0/-18
0/-18
7a
7a
ST
0/-18
25
-D
< 10
0/-18
7a
-A
< 10
< 15
0/-18
0/-18
7a
7a
ST
ST
< 10
0/-18
7a
-A
< 10
< 10
< 10
0/-18
0/-18
0/-18
7a
7a
7a
ST
ST
ST
< 10
0/-18
38
ESB
< 10
0/-18
8
-A
-A
See page 2-18 for Dimensions and Wiring Diagrams
PAGE 2-15
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp Certification
Starting
Line
Catalog
NOM
Qty. Method Volts
Number
F17T8 - Three Lamp Applications
120 B332I120L-A
•
•
277 B332I277L-A
•
•
347 B332I347L
•
120 B332I120RH-A
•
•
•
277 B332I277RH-A
•
•
•
347 B332I347RH
•
347 B332I347HPL
•
120
B332IUNVHP-A •
•
•
3 PAR-IS
277
347 B332I347HP
•
120
B332IUNVEL-A •
•
277
120 B332I120EL
•
•
277 B332I277EL
•
•
120
B332IUNVHE-A •
•
277
120 B332I120HE
•
•
277 B332I277HE
•
•
120
B332IUNVHEH-A •
•
277
120 B432I120RES-A* •
•
•
120
B432IUNV-D
•
•
277
120
ES1720B
•
•
277
120
3 SER-PRS
B332PUNVHP-A •
•
•
277
F17T8 - Four Lamp Applications
120 B432I120L-A
•
•
277 B432I277L-A
•
•
347 B432I347L
•
120 B432I120RES-A* •
•
•
120 B432I120RH-A
•
•
•
277 B432I277RH-A
•
•
•
347 B432I347RH
•
347 B432I347HPL
•
4 PAR-IS
120
B432IUNVHP-A •
•
•
277
347 B432I347HP
•
120
B432IUNV-D
•
•
277
120
B432IUNVEL-A •
•
277
120 B432I120EL
•
•
277 B432I277EL
•
•
120
B432IUNVHE-A •
•
277
120 B432I120HE
•
•
277 B432I277HE
•
•
277 B432I277HEH
•
•
120
ES1720B
•
•
277
120
4 SER-PRS
B432PUNVHP-A •
•
•
277
F25T8
• Standard & Low Profile
Designs Featured
TRIAD® ELECTRONIC BALLASTS
• Instant & Programmed
Rapid Starting Options
FOR (1) & (2) F25T8 LAMP
Fluorescent-Electronic
• 1-2 Lamp Applications
Lamp Certification
Line
Input Power Ballast
Ballast
Min. F/C
Starting
Line
Catalog Current Power Factor Factor Efficacy THD Start Wiring
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
F25T8 - One Lamp Applications
120 B132I120RH-A
•
•
•
0.22
26 > .97 0.92
3.54
< 25 0/-18
1
-A
277 B132I277RH-A
•
•
0.10
27 > .97 0.92
3.41
< 25 0/-18
1
-A
347 B132I347RH
•
0.07
25 > .95 0.90
3.60
< 20 0/-18
1
ST
120
0.21
B132IUNVHP-B •
•
24
>.95 0.88
3.67
< 10 0/-18
1
-B
277
0.09
1
IS
347 B132I347HP
•
0.07
25 > .95 0.90
3.60
< 10 0/-18
1
ST
120
0.18
> .98
B132IUNVEL-A •
•
19
0.78
4.11
<10 0/-18
1
-A
277
0.09
> .90
120
0.18
> .98
B132IUNVHE-A •
•
22
0.89
4.05
<10 0/-18
1
-A
277
0.10
> .95
120
0.20
> .99
1
PRS
B132PUNVHP-A •
•
•
24
0.91
3.79
< 10 0/-18
2
-A
277
0.09
> .98
347 ES1510A
•
•
0.07
24 > .97 0.87
2.81
< 10 0/-18
40 ESA
347 B232I347HPL
•
0.08
26 > .98 0.88
3.38
< 10 0/-18
3
ST
120 B232I120RES-A* •
•
•
0.43
28 > .50 1.08
3.86 < 150 0/-18
3a
-A
120 B232I120RES-G* •
•
•
0.43
28 > .50 1.08
3.86 < 150 0/-18
3a
-G
1
IS
120
0.24
B232IUNV-C
•
•
28 > .98 1.02
3.64
< 10 0/-18
21
-C
277
0.11
120
0.19
23
3.78
ES1608A
•
•
> .97 0.87
< 10 0/-18 39a ESA
277
0.09
24
3.63
120
0.22
25
3.92
1
PRS
ES4800A
•
•
> .97 1.02
< 10 0/-18
37 ESA
277
0.09
26
4.08
F25T8 - Two Lamp Applications
120 B232I120L-A
•
•
0.37
43 > .95 0.78
1.81
< 20 0/-18
3
-A
277 B232I277L-A
•
•
0.16
43 > .95 0.80
1.86
< 20 0/-18
3
-A
347 B232I347L-A
•
0.12
39 > .98 0.79
2.03
< 20 0/-18
3
-A
120 B232I120RES-A* •
•
•
0.64
46 > .50 0.92
2.00 < 130 0/-18
3
-A
120 B232I120RES-G* •
•
•
0.64
46 > .50 0.92
2.00 < 140 0/-18
3
-G
120 B232I120RH-A
•
•
•
0.41
48 > .95 0.93
1.94
< 20 0/-18
3
-A
277 B232I277RH-A
•
•
•
0.18
48 > .95 0.93
1.94
< 20 0/-18
3
-A
347 B232I347RH-A
•
0.13
46 > .95 0.89
1.93
< 20 0/-18
3
-A
347 B232I347HPL
•
0.12
41 > .98 0.75
1.83
< 10 0/-18
3
ST
120
0.37
45 > .99
2.00
B232IUNVHP-B •
•
•
0.90
< 10 0/-18
3
-B
277
0.16
44 > .98
2.05
2 PAR-IS 347 B232I347HP-A
•
0.13
46 > .95 0.89
1.93
< 10 0/-18
3
-A
120
0.37
45
2.00
B232IUNV-C
•
•
> .98 0.90
< 10 0/-18
21
-C
277
0.16
44
2.05
120
0.30
36
0.79
2.19
B232IUNVEL-A •
•
> .95
< 10 0/-18
3
-A
277
0.14
37
0.80
2.18
120 B232I120EL
•
•
0.33
39 > .98 0.78
2.00
< 10 0/-18
3
ST
277 B232I277EL
•
•
0.15
37 > .98 0.79
2.14
< 10 0/-18
3
ST
120
0.36
B232IUNVHE-A •
•
44 > .95 0.88
2.00
< 10 0/-18
3
-A
277
0.16
120
0.51
61
1.93
B232IUNVHEH-A •
•
> .95 1.18
< 10 0/-18
3
-A
277
0.22
60
1.97
120 B232I120HE
•
•
0.35
42 > .98 0.90
2.14
< 10 0/-18
3
ST
277 B232I277HE
•
•
0.16
43 > .98 0.90
2.09
< 10 0/-18
3
ST
120
0.36
2
SER-IS
ES1608A
•
•
43 > .97 0.87
2.02
< 10 0/-18
39 ESA
277
0.16
120
0.31
37
1.92
B232PUNVEL-A •
> .90 0.71
<10 0/-18
30 -A
277
0.14
36
2.00
120
0.35
42
1.98
B232PUNVHE-A •
> .90 0.83
<10 0/-18
30 -A
277
0.15
41
2.02
2 SER-PRS 120
0.40
47 > .99
2.00
B232PUNVHP-A •
•
•
0.94
<10 0/-18
30 -A
277
0.17
46 > .97
2.04
347 ES1329A
•
•
0.14
49 > .97 0.87
1.78
<10 0/-18
37 ESA
120
0.40
47
2.00
ES4800A
•
•
> .97 0.94
< 10 0/-18
37 ESA
277
0.17
46
2.04
* For Residential Use Only
See page 2-18 for Dimensions and Wiring Diagrams
PAGE 2-16
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (3) & (4) F25T8 LAMPS
F25T8
• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
• 3-4 Lamp Applications
* For Residential Use Only
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
0.52
0.22
0.17
0.60
0.26
0.20
0.17
0.55
0.25
0.20
0.49
0.22
0.47
0.20
0.56
0.24
0.52
0.24
0.69
0.30
0.58
0.26
0.96
0.62
0.26
0.52
0.24
61
62
60
70
70
68
60
66
65
68
59
58
56
56
67
66
61
64
83
81
70
71
74
72
63
64
> .95
< .98
> .99
> .95
> .95
> .95
> .99
> .99
> .98
> .99
> .99
> .97
> .98
> .98
> .99
> .98
> .98
> .98
> .95
> .99
> .95
> .50
0.68
0.30
0.24
1.13
0.74
0.32
0.26
0.24
0.74
0.32
0.26
0.73
0.31
0.65
0.28
0.60
0.28
0.72
0.31
0.71
0.32
0.41
0.69
0.31
0.77
0.33
78
76
83
85
87
84
90
83
87
85
90
87
85
78
76
77
77
87
85
85
86
114
83
92
89
> .95
> .95
> .98
> .50
> .95
> .95
> .95
> .98
> .99
> .95
> .98
> .98
> .98
> .97
> .98
> .98
> .98
> .99
> .98
> .98
> .98
> .99
> .97
> .99
> .95
1.34
1.34
1.26
1.33
1.33
1.32
1.26
1.36
1.38
1.34
1.36
1.38
1.39
1.41
1.34
1.36
1.44
1.41
1.40
1.43
1.31
1.38
1.32
1.36
1.38
1.36
0.78
0.78
0.78
0.90
0.91
0.91
0.90
0.78
0.89
0.90
0.90
0.78
0.80
0.79
0.89
0.89
0.89
1.19
0.87
0.89
< 25
< 20
< 20
< 20
< 25
< 20
< 10
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
6
6
6
6
6
6
6
-A
-A
ST
-A
-A
ST
ST
<10
0/-18
6
-A
< 10
0/-18
6
ST
< 10
0/-18
6
-A
< 10
< 10
0/-18
0/-18
6
6
ST
ST
< 10
0/-18
6
-A
< 10
< 10
0/-18
0/-18
6
6
ST
ST
< 10
0/-18
6
-A
< 10
0/-18
23
-A
< 130 0/-18
7a
-A
< 10
0/-18
24
-D
< 10
0/-18
38a ESB
1.00
1.03
0.94
1.06
1.05
1.08
1.00
0.94
1.02
1.05
1.00
1.03
1.06
1.00
1.03
1.04
1.03
1.02
1.05
1.05
1.03
1.04
< 20
< 20
< 20
< 130
< 20
< 20
< 20
< 10
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
7a
7a
7
7a
7a
7a
7a
7
-A
-A
ST
-A
-A
-A
ST
ST
< 10
< 10
0/-18
0/-18
7a
7a
-A
ST
< 10
0/-18
25
-D
< 10
0/-18
7a
-A
< 10
< 10
0/-18
0/-18
7a
7a
ST
ST
< 10
0/-18
7a
-A
< 10
< 10
< 10
0/-18
0/-18
0/-18
7a
7a
7a
ST
ST
ST
1.05
< 10
0/-18
38
ESB
0.97
1.00
< 10
0/-18
8
-A
See page 2-18 for Dimensions and Wiring Diagrams
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
SER-PRS = Series Programmed Rapid Start
PAGE 2-17
0.82
0.83
0.76
0.93
0.93
0.90
0.76
0.92
0.91
0.80
0.78
0.79
0.90
0.88
0.90
1.16
0.92
0.98
0.98
0.87
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp Certification
Starting
Line
Catalog
NOM
Qty. Method Volts
Number
F25T8 - Three Lamp Applications
120 B332I120L-A
•
•
277 B332I277L-A
•
•
347 B332I347L
•
120 B332I120RH-A
•
•
•
277 B332I277RH-A
•
•
•
347 B332I347RH
•
347 B332I347HPL
•
3 PAR-IS
120
B332IUNVHP-A •
•
•
277
347 B332I347HP
•
120
B332IUNVEL-A •
•
277
120 B332I120EL
•
•
277 B332I277EL
•
•
120
B332IUNVHE-A •
•
277
120 B332I120HE
•
•
277 B332I277HE
•
•
120
B332IUNVHEH-A •
•
277
120
3 SER-PRS
B332PUNVHP-A •
•
•
277
120 B432I120RES-A* •
•
•
3 PAR-IS
120
B432IUNV-D
•
•
277
120
ES1720B
•
•
277
F25T8 - Four Lamp Applications
120 B432I120L-A
•
•
277 B432I277L-A
•
•
347 B432I347L
•
120 B432I120RES-A* •
•
•
120 B432I120RH-A
•
•
•
277 B432I277RH-A
•
•
•
347 B432I347RH
•
347 B432I347HPL
•
4 PAR-IS 120
B432IUNVHP-A •
•
•
277
347 B432I347HP
•
120
B432IUNV-D
•
•
277
120
B432IUNVEL-A •
•
277
120 B432I120EL
•
•
277 B432I277EL
•
•
120
B432IUNVHE-A •
•
277
120 B432I120HE
•
•
277 B432I277HE
•
•
277 B432I277HEH
•
•
120
ES1720B
•
•
277
120
4 SER-PRS
B432PUNVHP-A •
•
•
277
F17T8
&
F25T8
TRIAD® ELECTRONIC BALLASTS
FOR F17T8 & F25T8 LAMPS
Overall Dimensions
Draw #
L
Fluorescent-Electronic
ST
-A
-B
-C
-D
-G
ESA
ESB
9.50”
9.50”
9.50”
14.25”
16.88”
9.50”
9.50”
9.50”
Mounting Dimensions
H
M
X
W
2.40”
1.70”
1.50”
1.18”
1.18”
1.18”
1.56”
2.38”
1.55”
1.18”
1.00”
1.00”
1.00”
1.00”
1.00”
1.00”
ST
8.89”
8.89”
8.89”
13.75”
16.20”
8.89”
8.88”
8.88”
WIRING DIAGRAMS
1.69”
1.69”
0.88”
------0.78”
---
DIAGRAM 2
DIAGRAM 1
DIAGRAM 3
-A, -B, -G, ESA, ESB
Line
Black
White
-C, -D
BALLAST
DIAGRAM 3a
Blue
Blue
Blue
Red
LAMP
LAMP
LAMP
DIAGRAM 6
DIAGRAM 7
DIAGRAM 37a
For three lamp operation, cap
any blue lead, insulate to 600V
DIAGRAM 8
DIAGRAM 7a
DIAGRAM 38
DIAGRAM 38a
DIAGRAM 21
DIAGRAM 21a
DIAGRAM 39
DIAGRAM 39a
DIAGRAM 30
DIAGRAM 23
DIAGRAM 40
DIAGRAM 24
PAGE 2-18
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (1) F32T8 LAMP
F32T8
• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
• 1 Lamp Applications
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAGE 2-19
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp Certification
Line
Input Power Ballast
Ballast
Min. F/C
Starting
Line
Catalog
Current Power Factor Factor Efficacy THD Start Wiring
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
F32T8 - One Lamp Applications
120 B132I120RH-A
•
•
•
0.26
31 > .98 0.88
2.84
< 20 0/-18
1
-A
277 B132I277RH-A
•
•
0.11
31 > .97 0.88
2.84
< 20 0/-18
1
-A
347 B132I347RH
•
0.09
31 > .98 0.88
2.84
< 20 0/-18
1
ST
120
0.25
30
2.93
B132IUNVHP-B •
•
> .95 0.88
< 10 0/-18
1
-B
277
0.12
29
3.03
347 B132I347HP
•
0.09
31 > .98 0.88
2.84
< 10 0/-18
1
ST
120
0.22
> .98
B132IUNVEL-A •
•
25
0.77
3.08
< 10 0/-18
1
-A
277
0.11
> .95
120
0.24
> .98
B132IUNVHE-A •
•
28
0.87
3.11
< 10 0/-18
1
-A
277
0.12
> .95
120 B232I120L-A
•
•
0.29
33 > .90 0.96
2.91
< 32 0/-18
3a
-A
277 B232I277L-A
•
•
0.13
33 > .90 1.00
3.03
< 32 0/-18
3a
-A
347 B232I347L-A
•
0.10
33 > .98 0.96
2.91
< 20 0/-18
3a
-A
120 B232I120RES-A* •
•
•
0.53
35 > .50 1.06
3.03 < 135 0/-18
3a
-A
120 B232I120RES-G* •
•
•
0.53
36 > .50 1.06
2.94 < 150 0/-18
3a
-G
120 B232I120RH-A
•
•
•
0.31
38 > .90 1.09
2.87
< 25 0/-18
3a
-A
277 B232I277RH-A
•
•
•
0.14
38 > .90 1.09
2.87
< 25 0/-18
3a
-A
347 B232I347RH-A
•
0.11
36 > .95 1.05
2.92
< 20 0/-18
3a
-A
347 B232I347HPL
•
0.09
32 > .98 0.91
2.84
< 10 0/-18
3a ST
120
0.29
> .99
1
IS
B232IUNVHP-B •
•
•
35
1.05
3.00
< 10 0/-18
3a
-B
277
0.13
> .98
347 B232I347HP-A
•
0.11
36 > .95 1.05
2.92
< 10 0/-18
3a
-A
120
0.29
B232IUNV-C
•
•
35
> .98 1.02
3.19
< 10 0/-18
22
-C
277
0.13
120
0.24
B232IUNVEL-A •
•
30 > .95 0.95
3.17
< 10 0/-18
3a
-A
277
0.11
120 B232I120EL
•
•
0.24
29 > .98 0.90
3.10
< 10 0/-18
3a ST
277 B232I277EL
•
•
0.11
30 > .98 0.92
3.07
< 10 0/-18
3a ST
120
0.28
B232IUNVHE-A •
•
33 > .95 1.05
3.18
< 10 0/-18
3a
-A
277
0.13
120
0.39
47
2.94
B232IUNVHEH-A1 •
•
> .95 1.38
< 10 0/-18
3a
-A
277
0.18
46
3.00
120 B232I120HE
•
•
0.27
33 > .98 1.00
3.03
< 10 0/-18
3a ST
277 B232I277HE
•
•
0.13
34 > .98 1.03
3.03
< 10 0/-18
3a ST
120
0.25
30
2.90
ES1608A
•
•
> .97 0.87
< 10 0/-18 39a ESA
277
0.11
31
2.81
120
0.24
B232PUNVHE-A •
29
> .90 0.88
3.03
< 10 0/-18
30
-A
277
0.11
120
0.20
25
2.89
B232PUNVEL-A •
> .90 0.88
< 10 0/-18
30
-A
277
0.09
23
3.09
120
0.26
31 > .99
2.84
B132PUNVHP-A •
•
•
0.88
< 10 0/-18
2
-A
1 PRS
277
0.11
30
> .98
2.93
347 ES1510A
•
0.09
31 > .97 0.87
2.81
< 10 0/-18
40 ESA
120
0.26
31 See page 2-23
3.23
Wiring 37
Diagrams
ES4800A
•
•
> .97 1.00 for Dimensions
< 10 and
0/-18
ESA
277
0.12
32
3.13
120
0.27
> .99
< 10
B232PUNVHP-A •
•
•
32
1.00
3.13
0/-18
30
-A
277
0.12
> .95
< 15
* For Residential Use Only
1 Consult Lamp Manufacturers for applications with Ballast Factor > 1.20
F32T8
TRIAD® ELECTRONIC BALLASTS
• Low Profile
Designs Featured
FOR (2) F32T8 LAMPS
• Instant & Programmed
Rapid Starting Options
Fluorescent-Electronic
• 2 Lamp Applications
Lamp Certification
Starting
Line
Catalog
NOM
Qty. Method Volts
Number
F32T8 - Two Lamp Applications
120 B232I120L-A
•
•
277 B232I277L-A
•
•
347 B232I347L-A
•
120 B232I120RES-A* •
•
•
120 B232I120RES-G* •
•
•
120 B232I120RH-A
•
•
•
277 B232I277RH-A
•
•
•
347 B232I347RH-A
•
120 B232I120RHH-A •
•
277 B232I277RHH-A •
•
347 B232I347HPL
•
2 PAR-IS 120
B232IUNVHP-B •
•
•
277
347 B232I347HP-A
•
120
B232IUNV-C
•
•
277
120
B232IUNVEL-A •
•
277
120 B232I120EL
•
•
277 B232I277EL
•
•
120
B232IUNVHE-A •
•
277
120
B232IUNVHEH-A •
•
277
120 B232I120HE
•
•
277 B232I277HE
•
•
347
B332IHRVHB-E •
•
480
2 SER-IS
120
ES1608A
•
•
277
120 B332I120L-A
•
•
277 B332I277L-A
•
•
347 B332I347L
•
120 B332I120RH-A
•
•
•
277 B332I277RH-A
•
•
•
347 B332I347RH
•
347 B332I347HPL
•
120
B332IUNVHP-A •
•
•
277
2 PAR-IS 347 B332I347HP
•
120
B332IUNVEL-A •
•
277
120 B332I120EL
•
•
277 B332I277EL
•
•
120
B332IUNVHE-A •
•
277
120 B332I120HE
•
•
277 B332I277HE
•
•
120
1
B332IUNVHEH-A •
•
277
120
B232PUNVEL-A •
277
2 SER-PRS 120
B232PUNVHE-A •
277
120
B232PUNVHP-A •
•
•
277
* For Residential Use Only
1 Consult lamp manufacturers
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
0.44
0.19
0.15
0.80
0.80
0.49
0.22
0.17
0.66
0.29
0.14
0.47
0.19
0.17
0.48
0.20
0.40
0.17
0.40
0.18
0.45
0.20
0.62
0.26
0.45
0.20
0.22
0.17
0.48
0.21
0.51
0.21
0.16
0.59
0.26
0.19
0.16
0.53
0.24
0.19
0.48
0.21
0.45
0.20
0.53
0.23
0.50
0.23
0.69
0.30
0.40
0.17
0.47
0.20
0.52
0.22
51
51
51
56
56
58
58
58
77
77
50
56
55
58
58
56
48
47
47
55
54
74
73
54
53
76
57
56
58
61
56
69
69
65
56
63
66
57
56
53
55
64
63
60
61
83
81
47
46
56
55
62
60
PAGE 2-20
> .95
> .95
> .98
> .50
> .50
> .98
> .98
> .99
> .98
> .98
> .99
0.78
0.78
0.78
0.88
0.88
0.88
0.88
0.88
1.18
1.18
0.78
0.88
> .99
> .99 0.88
> .98 0.88
> .95 0.77
1.53
1.53
1.53
1.57
1.57
1.52
1.52
1.52
1.53
1.53
1.56
1.57
1.60
1.52
1.52
1.57
< 20
< 20
< 20
< 120
< 130
< 20
< 20
< 20
< 20
< 20
< 10
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
3
3
3
3
3
3
3
3
3
3
3
-A
-A
-A
-A
-G
-A
-A
-A
-A
-A
ST
< 10
< 10
0/-18
0/-18
3
3
-A
< 10
0/-18
21
-B
-C
1.60
< 10
0/-18
3
-A
0.77
0.77
0.87
1.18
0.87
0.87
1.64
1.64
1.58
1.61
1.59
1.62
1.61
1.64
< 10
< 10
0/-18
0/-18
3
3
ST
ST
< 10
0/-18
3
-A
< 10
0/-18
3
-A
< 10
< 10
0/-18
0/-18
3
3
ST
ST
1.22
1.61
< 10
0/-18
46
-E
> .97 0.87
> .95 0.92
> .98 0.92
> .99 0.87
> .95 1.03
> .95 1.04
> .95 0.99
> .99 0.87
> .99
0.99
> .95
> .99 0.99
> .99
0.89
> .97
> .98 0.86
> .98 0.87
> .99
0.99
> .98
> .98 0.96
> .98 1.01
> .95 1.27
> .90
0.71
> .90
> .90
0.88
> .90
> .99
0.88
> .98
1.53
1.55
1.59
1.51
1.55
1.49
1.51
1.52
1.55
1.57
1.50
1.56
1.59
1.62
1.58
1.55
1.57
1.60
1.66
1.53
1.57
1.51
1.54
1.57
1.60
1.42
1.47
< 10
0/-18
39
ESA
< 25
< 20
< 20
< 25
< 25
< 20
< 10
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
6
6
6
6
6
6
6
-A
-A
ST
-A
-A
ST
ST
< 10
< 10
0/-18
6
-A
0/-18
6
ST
< 10
0/-18
6
-A
< 10
< 10
0/-18
0/-18
6
6
ST
ST
< 10
0/-18
6
-A
< 10
< 10
0/-18
0/-18
6
6
ST
ST
< 10
0/-18
6
-A
< 10
0/-18
30
-A
< 10
0/-18
30
-A
< 10
0/-18
30
-A
> .98
> .98
> .95
> .95
> .98
> .98
> .97
> .90
See page 2-23 for Dimensions and Wiring Diagrams
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (3) F32T8 LAMPS
F32T8
• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
• 3 Lamp Applications
Input
Power
(Watts)
58
60
59
64
63
76
76
75
86
86
85
113
113
75
85
83
88
74
73
70
70
83
81
80
79
111
108
110
109
92
90
83
83
83
92
92
92
95
83
92
89
92
92
91
80
78
79
76
89
87
88
89
119
80
82
92
90
PAGE 2-21
Power Ballast
Ballast
Min. F/C
Factor Factor Efficacy THD Start Wiring
(PF) (BF) Factor (BEF) %
Temp Diag. Dim.
1.50
> .97 0.87
< 10 0/-18
37 ESA
1.45
> .97 0.87
1.47
<10 0/-18
37 ESA
> .99
1.55
0.99
< 10 0/-18
23
-A
> .90
1.57
> .98
> .98
> .99
> .98
> .98
> .98
> .98
> .98
> .99
> .99
> .98
> .99
> .99
> .98
> .98
> .99
> .99
> .98
> .98
> .99
> .98
> .98
> .95
> .99
> .95
> .97
> .97
> .98
> .50
> .95
> .95
> .95
> .98
> .99
> .95
> .98
> .98
> .99
> .98
> .98
> .98
> .99
> .98
> .98
> .98
> .99
> .97
> .99
> .95
0.78
0.78
0.79
0.88
0.88
0.88
1.18
1.18
0.79
0.88
0.88
0.77
0.77
0.77
0.87
0.87
0.87
1.18
1.18
0.88
0.83
0.84
0.87
0.96
0.94
0.99
0.99
0.87
0.94
0.99
0.96
0.86
0.84
0.87
0.94
0.96
0.96
1.28
0.87
0.93
1.03
1.03
1.05
1.02
1.02
1.04
1.04
1.04
1.05
1.02
1.05
1.00
1.05
1.07
1.10
1.10
1.04
1.05
1.09
1.10
1.06
1.09
1.07
1.08
0.96
0.98
1.00
1.01
1.05
1.04
1.02
1.08
1.04
1.05
1.02
1.06
1.08
1.02
1.05
1.08
1.10
1.06
1.14
1.06
1.08
1.09
1.08
1.08
1.09
1.06
1.01
1.03
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 10
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
6
6
6
6
6
6
6
6
6
-A
-A
ST
-A
-A
ST
ST
ST
ST
< 10
< 10
0/-18
0/-18
6
6
-A
ST
< 10
0/-18
6
-A
< 10
< 10
0/-18
0/-18
6
6
ST
ST
< 10
0/-18
6
-A
< 10
< 10
0/-18
0/-18
6
6
ST
ST
< 10
0/-18
6
-A
< 10
0/-18
46
-E
< 10
< 20
< 20
< 20
< 130
< 20
< 20
< 20
< 10
< 10
< 10
< 10
0/-18
23
-A
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
7a
7a
7
7a
7a
7a
7a
7
-A
-A
ST
-A
-A
-A
ST
ST
0/-18
0/-18
7a
7a
-A
0/-18
24
-D
< 10
0/-18
7a
-A
< 10
< 10
0/-18
0/-18
7
7
ST
ST
< 10
0/-18
7a
-A
< 10
< 10
< 10
0/-18
0/-18
0/-18
7
7
7
ST
ST
ST
< 10
0/-18
< 10
0/-18
S
38a ESB
8
-A
See page 2-23 for Dimensions and Wiring Diagrams
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp Certification
Line
Starting
Line
Catalog Current
NOM
Qty. Method Volts
Number (Amps)
120
0.49
ES4800A
•
•
277
0.22
347 ES1329A
•
•
0.17
120
0.54
B332PUNVHP-A •
•
•
277
0.24
F32T8 - Three Lamp Applications
120 B332I120L-A
•
•
0.65
277 B332I277L-A
•
•
0.28
347 B332I347L
•
0.21
120 B332I120RH-A
•
•
•
0.75
277 B332I277RH-A
•
•
•
0.33
347 B332I347RH
•
0.25
120 B332I120RHH
•
•
0.98
277 B332I277RHH
•
•
0.43
347 B332I347HPL
•
0.21
3 PAR-IS 120
0.71
B332IUNVHP-A •
•
•
277
0.31
347 B332I347HP
•
0.25
120
0.61
B332IUNVEL-A •
•
277
0.26
120 B332I120EL
•
•
0.59
277 B332I277EL
•
•
0.26
120
0.70
B332IUNVHE-A •
•
277
0.30
120 B332I120HE
•
•
0.67
277 B332I277HE
•
•
0.30
120
0.91
B332IUNVHEH-A •
•
277
0.39
347
0.32
3 SER-IS
B332IHRVHB-E •
•
480
0.24
120
0.77
3 SER-RS
B332PUNVHP-A •
•
•
277
0.34
120 B432I120L-A
•
•
0.71
277 B432I277L-A
•
•
0.31
347 B432I347L
•
0.24
120 B432I120RES-A* •
•
•
1.20
120 B432I120RH-A
•
•
•
0.78
277 B432I277RH-A
•
•
•
0.33
347 B432I347RH
•
0.28
347 B432I347HPL
•
0.24
120
0.77
B432IUNVHP-A •
•
•
3 PAR-IS 277
0.34
347 B432I347HP
•
0.28
120
0.77
B432IUNV-D
•
•
277
0.33
120
0.67
B432IUNVEL-A •
•
277
0.29
120 B432I120EL
•
•
0.67
277 B432I277EL
•
•
0.28
120
0.74
B432IUNVHE-A •
•
277
0.32
120 B432I120HE
•
•
0.74
277 B432I277HE
•
•
0.33
•
•
0.43
277 B432I277HEH1
120
0.68
ES1720B
•
•
277
0.31
120
0.77
3 SER-PRS
B432PUNVHP-A •
•
•
277
0.34
* For Residential Use Only
1 Consult lamp manufacturers for applications with Ballast Factor > 1.20
F32T8
• Low Profile
Designs Featured
TRIAD® ELECTRONIC BALLASTS
FOR (4) F32T8 LAMPS
• Instant & Programmed
Rapid Starting Options
Fluorescent-Electronic
• 4 Lamp Applications
Lamp Certification
Line
Input Power Ballast
Ballast
Starting
Line
Catalog Current Power Factor Factor Efficacy THD
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF) (BF) Factor (BEF) %
F32T8 - Four Lamp Applications
120 B432I120L-A
•
•
0.85
100 > .98 0.78
0.78
< 20
277 B432I277L-A
•
•
0.36
98 > .98 0.78
0.80
< 20
347 B432I347L
•
0.29
101 > .99 0.78
0.77
< 20
120 B432I120RES-A* •
•
•
1.40
109 > .50 0.87
0.80 < 130
120 B432I120RH-A
•
•
•
0.93
112 > .99 0.88
0.79
< 20
277 B432I277RH-A
•
•
•
0.40
110 > .98 0.88
0.80
< 20
347 B432I347RH
•
0.33
114 > .98 0.88
0.77
< 20
347 B432I347HPL
•
0.29
101 > .99 0.78
0.77
< 10
120
0.93
112 > .99
0.79
B432IUNVHP-A •
•
•
0.88
< 10
277
0.40
108 > .98
0.80
347 B432I347HP
•
0.33
114 > .99 0.88
0.77
< 10
120
0.93
111
0.77
B432IUNV-D
•
•
> .98 0.88
< 10
4 PAR-IS
277
0.40
109
0.80
120
0.80
97 > .99
0.79
B432IUNVEL-A •
•
0.77
< 10
277
0.34
96 > .98
0.80
120 B432I120EL
•
•
0.81
95 > .99 0.77
0.81
< 10
277 B432I277EL
•
•
0.35
93 > .99 0.77
0.83
< 10
120
0.91
109
0.80
B432IUNVHE-A •
•
> .99 0.87
< 10
277
0.38
106
0.82
120 B432I120HE
•
•
0.90
106 > .99 0.87
0.82
< 10
277 B432I277HE
•
•
0.39
105 > .99 0.87
0.83
< 10
277 B432I277HEH
•
•
0.53
145 > .99 1.18
0.81
< 10
120
0.88
107
0.81
ES1720B
•
•
> .97 0.87
< 10
277
0.40
108
0.82
120
1.00
119 > .99
0.74
4 SER-PRS
B432PUNVHP-A •
•
•
0.88
< 10
277
0.42
115 > .98
0.77
* For Residential Use Only
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
Min. F/C
Start Wiring
Temp Diag. Dim.
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
7a
7a
7
7a
7a
7a
7a
7
-A
-A
ST
-A
-A
-A
ST
ST
0/-18
0/-18
7a
7a
-A
0/-18
25
-D
0/-18
7a
-A
0/-18
0/-18
7a
7a
ST
ST
0/-18
7a
-A
0/-18
0/-18
0/-18
7a
7a
7a
ST
ST
ST
0/-18
38
ESB
0/-18
8
-A
ST
See page 2-23 for Dimensions and Wiring Diagrams
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
SER-PRS = Series Programmed Rapid Start
PAGE 2-22
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
F32T8
FOR F32T8 LAMPS
Overall Dimensions
Draw #
L
ST
-A
-B
-C
-D
-E
-G
ESA
ESB
9.50”
9.50”
9.50”
14.25”
16.88”
16.88”
9.50”
9.50”
9.50”
W
2.40”
1.70”
1.50”
1.18”
1.18”
1.74”
1.18”
1.56”
2.38”
Mounting Dimensions
H
M
X
1.55”
1.18”
1.00”
1.00”
1.00”
1.18”
1.00”
1.00”
1.00”
8.89”
8.89”
8.89”
13.75”
16.20”
16.28”
8.89”
8.88”
8.88”
WIRING DIAGRAMS
1.69”
1.69”
0.88”
--------0.78”
---
DIAGRAM 1
For Three Lamp Application, Individually
cap brown leads, Insulate to 600V
DIAGRAM 8
-A, -B, -E, -G ESA, ESB
DIAGRAM 2
-C, -D
For Two Lamp operation, individually
cap yellow leads, Insulate to 600V
DIAGRAM 23
DIAGRAM 3
DIAGRAM 21
DIAGRAM 24
DIAGRAM 22
DIAGRAM 3a
Line
Black
White
DIAGRAM 37
BALLAST
Blue
Blue
Blue
Red
DIAGRAM 25
LAMP
LAMP
LAMP
DIAGRAM 39
For Two Lamp operation,
Insulate one blue lead to 600V
DIAGRAM 6
Line
Blue
Black
White
Yellow
Yellow
BALLAST
DIAGRAM 30
Blue
Red
Red
LAMP
DIAGRAM 39a
LAMP
LAMP
LAMP
For Three Lamp Operation,
Insulate one blue lead to 600V
DIAGRAM 7
DIAGRAM 40
DIAGRAM 38
For three lamp operation, cap any
blue lead, insulate to 600V
DIAGRAM 7a
DIAGRAM 38a
DIAGRAM 46
PAGE 2-23
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
ST
F32T8ES
30 WATT
• High Performance
Models and Low Profile
Designs
TRIAD® ELECTRONIC BALLASTS
• Instant and Programmed
Rapid Starting Options
FOR (1) & (2) F32T8ES(30 WATT) LAMPS
Fluorescent-Electronic
• 1-2 Lamp Applications
Lamp Certification
Starting
Line
Catalog
NOM
Qty. Method Volts
Number
F32T8ES(30W) - One Lamp Applications
277 B132I277RH-A
•
•
120
B132IUNVHP-B
•
•
277
1
IS
120
•
277 B132IUNVEL-A •
120
•
277 B132IUNVHE-A •
120
PRS
•
•
1
277 B132PUNVHP-A •
277 B232I277L-A
•
347 B232I347L-A
•
120 B232I120RH-A
•
•
•
277 B232I277RH-A
•
•
•
347 B232I347RH-A
•
120
•
•
1 PAR-IS 277 B232IUNVHP-B •
347 B232I347HP-A
•
120
B232IUNVEL-A
•
•
277
120 B232I120EL
•
•
277 B232I277EL
•
•
120
•
277 B232IUNVHE-A •
120
1
•
277 B232IUNVHEH-A •
120 B232I120HE
•
•
277 B232I277HE
•
•
120
B232PUNVEL-A
•
277
1
120
PRS
277 B232PUNVHE-A •
120
•
•
277 B232PUNVHP-A •
F32T8ES(30W) - Two Lamp Applications
120
•
•
277 B232IUNVEL-A
120 B232I120EL
•
•
277 B232I277EL
•
•
120
•
277 B232IUNVHE-A •
120
•
277 B232IUNVHEH-A •
120 B232I120HE
•
•
277 B232I277HE
•
•
277 B232I277L-A
•
347 B232I347L-A
•
2 PAR-IS 120 B232I120RH-A
•
•
•
277 B232I277RH-A
•
•
•
347 B232I347RH-A
•
120 B232I120RHH-A •
•
277 B232I277RHH-A •
•
120
B232IUNVHP-B
•
•
•
277
347 B232I347HP-A
•
120
277 B232PUNVEL-A •
120
2 SER-PRS
277 B232PUNVHE-A •
120
•
•
277 B232PUNVHP-A •
120 B332I120RH-A
•
•
•
277 B332I277RH-A
•
•
•
120
•
•
277 B332IUNVHP-A •
2 PAR-IS 120
•
277 B332IUNVEL-A •
120 B332I120EL
•
•
277 B332I277EL
•
•
120
B332IUNVHE-A
•
•
277
1 Consult lamp manufacturers
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
0.11
0.25
0.11
0.22
0.11
0.24
0.12
0.23
0.10
0.12
0.15
0.32
0.15
0.15
0.28
0.12
0.15
0.23
0.11
0.24
0.11
0.25
0.12
0.37
0.16
0.26
0.12
0.19
0.09
0.22
0.10
0.25
0.11
0.38
0.17
0.38
0.17
0.42
0.19
0.59
0.25
0.43
0.19
0.18
0.14
0.47
0.21
0.10
0.63
0.26
0.44
0.19
0.10
0.37
0.16
0.43
0.18
0.50
0.21
0.54
0.23
0.50
0.22
0.46
0.20
0.42
0.19
0.49
0.21
29
29
25
28
28
33
51
35
38
54
33
53
> .97
> .95
> .98
> .95
> .98
> .95
> .99
> .98
> .90
> .98
> .90
> .90
> .98
> .99
> .98
> .98
0.94
3.24
0.77
32
43
30
32
22
23
27
26
30
> .95
> .95
> .98
> .98
> .90
> .90
> .99
> .95
28
28
28
46
44
44
52
51
70
68
51
50
49
48
55
58
34
73
73
53
52
34
45
44
50
49
60
58
63
63
59
54
53
51
50
59
57
PAGE 2-24
> .95
> .98
> .98
> .95
> .98
> .98
> .95
> .95
> .98
> .98
> .95
> .98
> .98
> .98
> .98
> .98
> .98
> .99
> .98
> .98
> .90
> .90
> .99
> .98
> .96
> .97
> .99
> .95
> .99
> .98
> .98
> .98
> .99
> .97
60/16
1
-A
3.08
< 15
<10
< 10
60/16
1
-A
0.87
3.11
< 10
60/16
1
-A
0.88
0.98
0.78
1.10
1.10
0.88
1.05
0.88
3.14
2.97
1.53
3.14
2.89
1.63
3.18
1.66
< 10
< 32
< 20
< 32
< 25
< 20
60/16
60/16
60/16
60/16
60/16
60/16
2
3a
3a
3a
3a
3a
-A
-A
-A
-A
-A
-A
1.05
1.38
1.00
1.03
0.72
0.88
1.00
3.28
3.21
3.33
3.22
3.27
3.12
3.26
3.38
3.33
< 10
< 10
< 10
< 10
60/16
60/16
60/16
3a
3
3
-A
ST
ST
0.88
0.92
0.89
0.92
0.77
0.77
0.77
0.87
1.18
0.87
0.87
0.77
0.96
0.89
0.89
1.04
1.18
1.18
0.88
1.04
0.71
0.87
0.88
1.01
1.00
0.99
0.89
0.86
0.86
0.99
3.03
3.92
3.18
3.29
1.67
1.75
1.75
1.67
1.71
1.69
1.74
1.71
1.74
1.57
3.10
1.62
1.53
3.06
1.62
1.62
1.66
1.69
3.06
1.59
1.61
1.74
1.78
1.47
1.52
1.60
1.59
1.68
1.65
1.68
1.69
1.72
1.68
1.74
< 10
< 10
60/16
60/16
60/16
60/16
1
3a
3a
3a
-B
-B
-A
-A
< 10
< 10
< 10
< 10
< 10
60/16
60/16
60/16
60/16
60/16
3a
3
3
30
30
-A
ST
ST
< 10
60/16
30
-A
< 10
< 10
< 10
60/16
60/16
60/16
3
3
3
-A
ST
ST
< 10
< 10
< 10
< 20
< 20
< 20
< 20
< 20
<20
<20
60/16
60/16
60/16
60/16
60/16
60/16
60/16
60/16
60/16
60/16
3
3
3
3
3
3
3
3
3
3
-A
ST
ST
-A
-A
-A
-A
-A
-A
-A
< 10
< 10
< 10
< 10
< 10
60/16
3
-A
-A
-A
60/16
60/16
60/16
60/16
3
3
30
30
< 10
< 25
< 25
60/16
60/16
60/16
30
6
6
-A
-A
-A
< 10
< 10
< 10
60/16
60/16
60/16
6
6
6
-A
ST
ST
< 10
< 10
60/16
60/16
6
6
-B
-A
-A
-A
-A
-A
See page 2-30 for Dimensions and Wiring Diagrams
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (2)(cont.), (3) & (4) F32T8ES LAMPS
F32T8ES
• High Performance
Models and Low Profile
Designs
30 WATT
• Instant and Programmed
Rapid Starting Options
• 3-4 Lamp Applications
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
0.47
0.21
0.65
0.28
0.21
0.16
0.51
0.23
57
58
78
76
71
61
60
> .98
> .98
> .95
> .97
> .90
> .99
>.90
0.96
0.99
1.28
0.69
0.30
0.66
0.29
0.58
0.25
0.56
0.24
0.65
0.28
0.63
0.28
0.86
0.37
0.30
0.22
0.73
0.32
0.65
0.71
0.26
0.26
0.72
0.32
0.62
0.27
0.61
0.27
0.70
0.30
0.70
0.31
0.73
0.32
81
81
79
77
70
69
66
65
79
77
76
75
104
101
102
101
87
85
78
85
88
88
86
84
75
73
73
73
84
82
83
84
87
85
> .98
> .98
> .99
> .95
> .99
> .98
> .98
> .99
> .99
> .98
> .98
> .99
> .95
> .98
> .95
> .99
> .95
> .98
> .99
> .98
> .98
> .98
> .95
> .99
> .98
> .98
> .98
0.80
0.87
0.31
0.31
0.87
0.38
0.80
0.34
0.75
0.32
0.91
0.38
0.85
0.37
0.49
0.95
0.41
95
104
106
106
104
101
97
96
89
87
109
106
100
99
134
114
110
> .98
> .99
> .99
> .99
> .98
> .95
> .99
> .98
> .99
> .99
> .98
> .98
> .98
> .99
> .95
> .99
> .99
> .99
> .99
> .99
> .95
60/16
60/16
6
6
ST
ST
1.72
1.62
1.65
< 10
60/16
46
-E
<10
60/16
23
-A
0.88
0.88
0.89
0.77
0.77
0.77
0.87
0.87
0.87
1.18
1.18
0.88
0.86
0.88
0.99
0.99
0.96
0.86
0.85
0.84
0.96
0.96
0.96
0.93
1.09
1.09
1.13
1.16
1.10
1.12
1.17
1.18
1.10
1.13
1.14
1.16
1.13
1.17
1.16
1.17
1.01
1.04
1.10
1.04
1.13
1.13
1.12
1.14
1.15
1.18
1.16
1.15
1.14
1.17
1.16
1.14
1.07
1.09
< 20
< 20
60/16
60/16
6
6
-A
-A
< 10
60/16
6
-A
0.80
0.88
0.88
0.88
0.88
0.77
0.77
0.77
0.87
0.87
0.87
1.18
0.88
0.84
0.85
0.83
0.83
0.85
0.87
0.79
0.80
0.87
0.89
0.80
0.82
0.87
0.88
0.88
0.77
0.80
< 10
60/16
6
-A
< 10
60/16
6
-A
< 10
< 10
60/16
60/16
6
6
ST
ST
< 10
60/16
6
-A
< 10
< 10
60/16
60/16
6
6
ST
ST
< 10
60/16
6
-A
< 10
60/16
46
-E
< 10
60/16
23
-A
< 20
< 10
< 10
< 20
60/16
60/16
60/16
60/16
7a
7a
7a
7a
-A
-A
ST
ST
< 10
60/16
7a
-A
< 10
60/16
7a
-A
< 10
< 10
60/16
60/16
7a
7a
ST
ST
< 10
60/16
7a
-A
< 10
< 10
60/16
60/16
7
7
ST
ST
< 10
60/16
8
-A
< 20
< 10
< 10
< 20
60/16
60/16
60/16
60/16
7a
7a
7a
7a
-A
-A
ST
ST
< 10
60/16
7a
-A
< 10
60/16
7a
-A
< 10
< 10
60/16
60/16
7a
7a
ST
ST
< 10
60/16
7a
-A
< 10
< 10
< 10
60/16
60/16
60/16
7a
7a
7a
ST
ST
ST
< 10
60/16
8
-A
See page 2-30 for Dimensions and Wiring Diagrams
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
SER-PRS = Series Programmed Rapid Start
PAGE 2-25
< 10
< 10
1.22
0.99
1.68
1.71
1.64
1.68
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
SER-IS = Series Instant Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp Certification
Starting
Line
Catalog
NOM
Qty. Method Volts
Number
F32T8ES(30W) - Two Lamp Applications
120 B332I120HE
•
•
2 PAR-IS 277 B332I277HE
•
•
120
•
277 B332IUNVHEH-A •
347
•
2 SER-IS
480 B332IHRVHB-E •
120
•
•
2 SER-PRS
277 B332PUNVHP-A •
F32T8ES(30W) - Three Lamp Applications
120 B332I120RH-A
•
•
•
277 B332I277RH-A
•
•
•
120
B332IUNVHP-A •
•
•
277
3 PAR-IS 120
B332IUNVEL-A •
•
277
120 B332I120EL
•
•
277 B332I277EL
•
•
120
B332IUNVHE-A •
•
277
120 B332I120HE
•
•
277 B332I277HE
•
•
120
B332IUNVHEH-A •
•
277
347
3 SER-IS
B332IHRVHB-E •
•
480
120
3 SER-PRS
B332PUNVHP-A •
•
•
277
120 B432I120L-A
•
120 B432I120RH-A
•
•
•
347 B432I347HP
•
347 B432I347RH
•
120
B432IUNVHP-A •
•
•
277
3 PAR-IS 120
B432IUNVEL-A •
•
277
120 B432I120EL
•
•
277 B432I277EL
•
•
120
B432IUNVHE-A •
•
277
120 B432I120HE
•
•
277 B432I277HE
•
•
3 SER-PRS
120
B432PUNVHP-A •
•
•
277
F32T8ES(30W) - Four Lamp Applications
120 B432I120L-A
•
120 B432I120RH-A
•
•
•
347 B432I347HP
•
347 B432I347RH
•
120
B432IUNVHP-A •
•
•
277
4 PAR-IS 120
B432IUNVEL-A •
•
277
120 B432I120EL
•
•
277 B432I277EL
•
•
120
B432IUNVHE-A •
•
277
120 B432I120HE
•
•
277 B432I277HE
•
•
277 B432I277HEH
•
•
120
4 SER-PRS
B432PUNVHP-A •
•
•
277
F32T8ES
Fluorescent-Electronic
(25 WATT)
• High Performance
Models and Low Profile
Designs
• 1-2 Lamp Applications
TRIAD® ELECTRONIC BALLASTS
FOR (1) & (2)
F32T8ES (25 WATT) LAMPS
Lamp Certification
Line
Input Power Ballast
Ballast
Min. F/C
Starting
Line
Catalog Current Power Factor Factor Efficacy THD Start Wiring
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
F32T8ES (25W) - One Lamp Applications
120
0.24
B132IUNVHP-B •
•
24
> .95 0.88
3.67
< 10 60/16
1
-B
277
0.09
120
0.17
> .98
B132IUNVEL-A •
•
20
0.77
3.85
< 10 60/16
1
-A
277
0.07
> .95
120
0.19
> .98
B132IUNVHE-A •
•
23
0.87
3.78
< 10 60/16
1
-A
277
0.09
> .95
120
0.23
> .99
B232IUNVHP-B •
•
•
28
1.05
3.75
< 10 60/16
3a
-B
277
0.10
> .98
1
IS
120
0.20
24 > .99
3.96
< 10
B232IUNVEL-A •
•
0.95
60/16
3a
-A
277
0.09
25 > .95
3.80
< 15
120 B232I120EL
•
•
0.19
23 > .98 0.89
3.87
< 10 60/16
3a ST
277 B232I277EL
•
•
0.08
23 > .98 0.92
4.00
< 15 60/16
3a ST
120
0.23
> .98
B232IUNVHE-A •
•
27
1.05
3.89
< 10 60/16
3a
-A
277
0.10
> .95
0.32
38
3.63
120
•
> .95 1.38
< 10 60/16
3a
-A
B232IUNVHEH-A1 •
277
0.14
37
3.73
120 B232I120HE
•
•
0.21
25 > .98 1.00
4.00
< 10 60/16
3
ST
277 B232I277HE
•
•
0.90
24 > .98 1.03
4.29
< 10 60/16
3
ST
120
0.21
B132PUNVHP-A •
•
•
25
> .99 0.88
3.52
< 10 60/16
2
-A
277
0.09
120
0.16
19
3.74
0.71
< 10 60/16
30
-A
277 B232PUNVEL-A •
0.08
19 > .90
3.74
1
PRS
120
0.20
25
3.52
0.88
< 10 60/16
30
-A
277 B232PUNVHE-A •
0.09
24 > .90
3.67
120
0.22
> .99
B232PUNVHP-A •
•
•
27
1.00
3.70
< 10 60/16
30 -A
277
0.10
>.94
F32T8ES (25W) - Two Lamp Applications
120
0.37
44 > .99
2.00
B232IUNVHP-B •
•
•
0.88
< 10 60/16
3
-B
277
0.16
43 > .98
2.05
120
0.33
39 > .99
1.97
B232IUNVEL-A •
•
0.77
< 10 60/16
3
-A
277
0.14
38 > .98
2.03
120 B232I120EL
•
•
0.31
37 > .98 0.77
2.08
< 10 60/16
3
ST
277 B232I277EL
•
•
0.14
37 > .98 0.77
2.08
< 10 60/16
3
ST
120
0.37
44
1.98
B232IUNVHE-A •
•
> .98 0.87
< 10 60/16
3
-A
277
0.16
43
2.02
120
0.49
59
2.00
B232IUNVHEH-A •
•
> .95 1.18
< 10 60/16
3
-A
277
0.21
58
2.03
120 B232I120HE
•
•
0.34
41 > .98 0.87
2.12
< 10 60/16
3
ST
277 B232I277HE
•
•
0.15
41 > .98 0.87
2.12
< 10 60/16
3
ST
2 PAR-IS 120
0.43
> .98
B332IUNVHP-A •
•
•
51
1.00
1.96
< 10 60/16
6
-A
277
0.20
> .90
120
0.37
44 > .99
2.02
B332IUNVEL-A •
•
0.89
< 10 60/16
6
-A
277
0.16
43 > .95
2.07
120 B332I120EL
•
•
0.35
42 > .98 0.86
2.05
< 10 60/16
6
ST
277 B332I277EL
•
•
0.16
43 > .98 0.86
2.00
< 10 60/16
6
ST
120
0.43
51 > .98
1.94
B332IUNVHE-A •
•
0.99
< 10 60/16
6
-A
277
0.19
50 > .95
1.98
120 B332I120HE
•
•
0.40
48 > .98 0.96
2.00
< 10 60/16
6
ST
277 B332I277HE
•
•
0.17
48 > .99 0.99
2.06
< 10 60/16
6
ST
120
0.55
66
1.94
1
B332IUNVHEH-A •
•
> .95 1.28
< 10 60/16
6
-A
277
0.25
65
1.97
347
0.18
> .95
B332IHRVH-E
•
•
61
1.14
1.87
< 10 60/16
46
-E
480
0.14
> .90
120
0.43
52 > .99
1.69
2 SER-IS
B232PUNVHP-A •
•
•
0.88
< 10 60/16
30 -A
277
0.19
51 > .98
1.73
120
0.42
> .99
B332PUNVHP-A •
•
•
50
0.99
1.98
< 10 60/16
23 -A
277
0.20
> .90
120
0.32
38
1.87
B232PUNVEL-A
•
>
.90
0.71
<
10
60/16
30
-A
277
0.14
38
1.87
2
SER-PRS
120
0.37
44
1.98
0.87
< 10 60/16
30
-A
277 B232PUNVHE-A •
0.16
41 > .90
2.02
1 Consult lamp manufacturers for applications with Ballast Factor > 1.20
See page 2-30 for Dimensions and Wiring Diagrams
PAGE 2-26
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (3) & (4)
F32T8ES (25 WATT) LAMPS
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
0.57
0.26
0.48
0.21
0.47
0.20
0.24
0.60
0.54
0.23
0.72
0.32
0.26
0.19
0.61
0.27
0.51
0.22
0.60
0.26
0.57
0.25
0.61
0.27
0.62
0.28
69
68
58
57
56
56
66
65
64
64
87
85
88
73
72
61
61
72
71
68
69
73
71
75
73
> .99
> .95
> .99
> .97
> .98
> .98
> .98
> .95
> .98
> .99
> .95
> .97
> .90
> .98
> .95
> .98
> .98
> .99
> .95
> .99
> .99
> .99
> .95
> .99
> .95
0.90
0.77
0.77
0.77
0.87
0.87
0.87
1.18
1.11
0.97
0.85
0.87
0.96
0.96
0.96
0.88
0.93
1.30
1.32
1.33
1.35
1.38
1.38
1.32
1.34
1.36
1.36
1.36
1.39
1.26
0.74
0.33
0.62
0.26
90
88
74
72
> .98
> .95
> .98
> .98
0.89
0.77
0.77
0.99
1.01
1.04
1.07
4 PAR-IS 120
0.73
B432IUNVHE-A •
•
277
0.31
120 B432I120HE
•
•
0.70
277 B432I277HE
•
•
0.30
120
0.84
4 SER-PRS
B432PUNVHP-A •
•
•
277
0.36
1 Consult lamp manufacturers for applications with Ballast Factor > 1.20
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
(25 WATT)
• 3-4 Lamp Applications
87
85
84
84
100
98
> .99
> .98
> .99
> .99
> .99
> .95
1.00
1.02
1.04
1.04
0.88
0.90
60/16
6
-A
< 10
60/16
6
-A
< 10
< 10
60/16
60/16
6
6
ST
ST
< 10
60/16
6
-A
< 10
< 10
60/16
60/16
6
6
ST
ST
< 10
60/16
6
-A
< 10
60/16
46
-E
< 10
60/16
7a
-A
< 10
< 10
60/16
60/16
7
7
ST
ST
< 10
60/16
7a
-A
< 10
< 10
60/16
60/16
7a
7a
ST
ST
< 10
60/16
23
-A
< 10
60/16
8
-A
< 10
60/16
7a
-A
< 10
< 10
60/16
60/16
7a
7a
ST
ST
<10
60/16
7a
-A
< 10
< 10
< 10
60/16
60/16
7a
7a
ST
ST
60/16
8
-A
See page 2-30 for Dimensions and Wiring Diagrams
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
SER-PRS = Series Programmed Rapid Start
PAGE 2-27
0.87
0.87
0.87
0.88
1.33
1.35
1.39
1.43
1.33
1.35
1.41
1.39
1.21
1.24
1.24
1.27
< 10
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
SER-IS = Series Instant Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp Certification
Starting
Line
Catalog
NOM
Qty. Method Volts
Number
F32T8ES (25W) - Three Lamp Applications
120
B332IUNVHP-A •
•
•
277
120
B332IUNVEL-A •
•
277
120 B332I120EL
•
•
3 PAR-IS 277 B332I277EL
•
•
120
B332IUNVHE-A •
•
277
120 B332I120HE
•
•
277 B332I277HE
•
•
120
B332IUNVHEH-A •
•
277
347
3 SER-IS
B332IHRVHB-E •
•
480
120
B432IUNVHP-A •
•
•
277
120 B432I120EL
•
•
3 PAR-IS 277 B432I277EL
•
•
120
B432IUNVHE-A •
•
277
120 B432I120HE
•
•
274 B432I277HE
•
•
120
B332PUNVHP-A •
•
•
277
3 SER-PRS
120
B432PUNVHP-A •
•
•
277
F32T8ES (25W) - Four Lamp Applications
120
B432IUNVHP-A •
•
•
277
120 B432I120EL
•
•
277 B432I277EL
•
•
F32T8ES
• High Performance
Models and Low Profile
Designs
F28T8
TRIAD® ELECTRONIC BALLASTS
FOR (1) & (2) F28T8 LAMPS
• High Performance
Models and Low Profile
Designs
• Instant and Programmed
Rapid Starting Options
Fluorescent-Electronic
• 1-2 Lamp Applications
Lamp Certification
Line
Input Power Ballast
Ballast
Min. F/C
Starting
Line
Catalog Current Power Factor Factor Efficacy THD Start Wiring
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
F28T8 - One Lamp Applications
277 B132I277RH-A
•
•
0.10
27 > .98 0.97
3.59
< 20 60/16
1
-A
120
0.21
B132IUNVHP-B •
•
26
> .95 0.88
3.38
< 10 60/16
1
-B
277
0.09
120
0.20
> .98
B132IUNVEL-A •
•
21
0.77
3.67
< 10 60/16
1
-A
277
0.10
> .95
120
0.20
> .98
B132IUNVHE-A •
•
24
0.87
3.63
< 10 60/16
1
-A
277
0.10
> .95
277 B232I277L-A
•
•
0.12
30 > .90 0.96
3.20
< 32 60/16
3a
-A
347 B232I347L-A
•
0.08
29 > .98 0.96
3.31
< 20 60/16
3a
-A
120 B232I120RH-A
•
•
•
0.30
33 > .90 1.10
3.33
< 32 60/16
3a
-A
277 B232I277RH-A
•
•
•
0.13
33 > .90 1.10
3.33
< 32 60/16
3a
-A
1
IS
347 B232I347RH-A
•
0.09
32 > .98 1.04
3.25
< 20 60/16
3a
-A
120
0.26
31 > .99
3.39
B232IUNVHP-B •
•
•
1.05
< 10 60/16
3a
-B
277
0.11
30 > .98
3.50
347 B232I347HP-A
•
0.09
32 > .98 0.88
3.25
< 10 60/16
3a
-A
120
0.22
26
3.65
B232IUNVEL-A •
•
> .95 0.95
< 10 60/16
3a
-A
277
0.10
27
3.52
120 B232I120EL
•
•
0.23
28 > .98 0.92
3.29
< 10 60/16
3a ST
277 B232I277EL
•
•
0.09
26 > .98 0.92
3.54
< 10 60/16
3a ST
120
0.24
B232IUNVHE-A •
•
29 > .95 1.10
3.79
< 10 60/16
3a
-A
277
0.11
120
0.33
40
3.45
B232IUNVHEH-A1 •
•
> .95 1.38
< 10 60/16
3a
-A
277
0.15
39
3.54
120 B232I120HE
•
•
0.23
28 > .98 1.01
3.61
< 10 60/16
3a ST
277 B232I277HE
•
•
0.12
29 > .98 1.02
3.52
< 10 60/16
3a ST
120
0.28
B132PUNVHP-A •
•
•
27
> .99 0.88
3.26
< 10 60/16
2
-A
277
0.11
120
0.18
21
3.38
0.71
< 10 60/16
30
-A
277 B232PUNVEL-A •
0.08
21 > .90
3.38
PRS
1
120
0.21
25
3.49
0.88
< 10 60/16
30
-A
277 B232PUNVHE-A •
0.09
24 > .90
3.67
120
0.25
> .99
B232PUNVHP-A •
•
•
30
1.00
3.33
< 10 60/16
30 -A
277
0.11
>.95
F28T8 - Two Lamp Applications
277 B232I277L-A
•
•
0.17
45 > .95 0.75
1.67
< 25 60/16
3
-A
347 B232I347L-A
•
0.13
44 > .98 0.78
1.77
< 20 60/16
3
-A
120 B232I120RH-A
•
•
•
0.43
51 > .98 0.90
1.76
< 20 60/16
3
-A
277 B232I277RH-A
•
•
•
0.19
51 > .98 0.90
1.76
< 20 60/16
3
-A
347 B232I347RH-A
•
0.14
50 > .98 0.88
1.76
< 20 60/16
3
-A
120
0.41
48 > .99
1.83
B232IUNVHP-B •
•
•
0.88
< 10 60/16
3
-B
277
0.17
47 > .98
1.87
347 B232I347HP-A
•
0.14
50 > .98 1.04
1.76
< 10 60/16
3
-A
120
0.36
B232IUNVEL-A •
•
43 > .95 0.77
1.79
< 10 60/16
3
-A
277
0.15
120 B232I120EL
•
•
0.35
41 > .98 0.77
1.88
< 10 60/16
3
ST
277 B232I277EL
•
•
0.14
41 > .98 0.77
1.88
< 10 60/16
3
ST
120
0.40
49
1.78
B232IUNVHE-A •
•
> .95 0.87
< 10 60/16
3
-A
2 PAR-IS 277
0.18
48
1.81
120
0.53
64
1.84
B232IUNVHEH-A •
•
> .95 1.18
< 10 60/16
3
-A
277
0.23
62
1.90
120 B232I120HE
•
•
0.38
48 > .98 0.87
1.81
< 10 60/16
3
ST
277 B232I277HE
•
•
0.17
47 > .98 0.87
1.85
< 10 60/16
3
ST
120 B332I120RH-A
•
•
•
0.50
57 > .95 1.02
1.79
< 32 60/16
6
-A
277 B332I277RH-A
•
•
•
0.22
57 > .95 1.00
1.75
< 25 60/16
6
-A
120
0.46
55 > .99
1.80
B332IUNVHP-A •
•
•
0.99
< 10 60/16
6
-A
277
0.21
54 > .90
1.83
120
0.41
49 > .99
1.82
B332IUNVEL-A •
•
0.89
< 10 60/16
6
-A
277
0.18
48 > .95
1.85
120 B332I120EL
•
•
0.38
45 > .98 0.86
1.91
< 10 60/16
6
ST
277 B332I277EL
•
•
0.18
47 > .98 0.88
1.87
< 10 60/16
6
ST
120
0.45
54 > .99
1.83
B332IUNVHE-A •
•
0.99
< 10 60/16
6
-A
277
0.19
53 > .97
1.87
120
0.57
71
1.80
B332IUNVHEH-A1 •
•
> .95 1.28
< 10 60/16
6
-A
277
0.27
69
1.86
1 Consult lamp manufacturers for applications with Ballast Factors > 1.20
See page 2-30 for Dimensions and Wiring Diagrams
PAGE 2-28
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (2)(cont.), (3) & (4) F28T8 LAMPS
F28T8
• High Performance
Models and Low Profile
Designs
• Instant and Programmed
Rapid Starting Options
• 2-4 Lamp Applications
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
Line
Input Power
Current Power Factor
(Amps) (Watts) (PF)
0.42
51 > .98
0.20
52 > .98
0.19
> .97
65
0.15
> .90
0.25
> .99
30
0.11
> .95
0.34
41
0.15
40 > .90
0.39
47
0.17
46 > .90
0.46
55 > .99
0.21
54 > .90
Ballast
Ballast
Min. F/C
Factor Efficacy THD Start Wiring
(BF) Factor (BEF) %
Temp Diag. Dim.
0.96
1.88
< 10 60/16
6
ST
0.98
1.88
< 10 60/16
6
ST
1.22
1.00
0.70
0.87
0.99
1.88
< 10
60/16
46
-E
3.33
< 10
60/16
30
-A
1.71
1.75
1.85
1.89
1.80
1.83
< 10
< 10
60/16
60/16
30
30
-A
< 10
60/16
23
-A
-A
0.63
0.27
0.61
0.27
0.53
0.23
0.50
0.22
0.60
0.26
0.57
0.24
0.78
0.34
0.28
0.21
0.23
0.23
0.66
0.29
0.57
0.26
0.25
0.64
0.28
0.28
0.66
0.29
0.68
0.30
74
74
73
71
66
65
62
61
75
73
72
71
95
92
94
78
78
79
77
69
68
66
77
75
74
79
78
82
80
> .98
> .98
> .99
> .95
> .99
> .97
> .98
> .98
> .99
> .98
> .98
> .98
> .95
> .97
> .90
> .98
> .98
> .98
> .95
> .99
> .95
> .98
> .99
> .98
> .98
> .99
> .95
> .99
> .95
0.88
0.88
0.89
0.77
0.77
0.77
0.87
0.87
0.87
1.18
1.18
0.99
0.99
0.97
0.97
0.86
0.88
0.96
0.98
0.88
0.93
1.19
1.19
1.22
1.25
1.17
1.18
1.24
1.26
1.16
1.19
1.21
1.23
1.24
1.28
1.26
< 20
< 20
60/16
60/16
6
6
-A
-A
< 10
60/16
6
-A
1.27
1.27
1.23
1.26
1.25
1.26
1.33
1.25
1.28
1.32
1.11
1.13
1.13
1.16
< 10
0.28
0.28
0.80
0.35
0.70
0.31
0.75
0.29
0.77
0.33
0.85
0.32
0.45
0.89
0.39
95
95
96
93
85
84
83
81
97
94
94
93
123
107
104
> .99
> .99
> .98
> .95
> .99
> .98
> .99
> .98
> .99
> .98
> .99
> .98
> .99
> .99
> .95
0.88
0.88
0.89
0.88
0.77
0.77
0.77
0.87
0.87
0.87
1.18
0.88
0.93
0.93
0.93
0.95
0.91
0.92
0.93
0.95
0.90
0.93
0.93
0.94
0.96
0.82
0.85
60/16
6
-A
60/16
60/16
6
6
ST
ST
< 10
60/16
6
-A
< 10
< 10
60/16
60/16
6
6
ST
ST
< 10
60/16
6
-A
< 10
60/16
46
-E
< 10
< 10
60/16
60/16
7a
7a
ST
ST
60/16
7a
-A
< 10
60/16
7a
-A
< 10
60/16
7a
ST
< 10
60/16
7a
-A
< 10
60/16
7a
ST
< 10
60/16
23
-A
< 10
60/16
8
-A
< 10
< 20
60/16
60/16
7a
7a
ST
ST
< 10
60/16
7a
-A
< 10
60/16
7a
-A
< 10
< 10
60/16
60/16
7a
7a
ST
ST
< 10
60/16
7a
-A
< 10
< 10
< 10
60/16
60/16
60/16
7a
7a
7a
ST
ST
ST
< 10
60/16
8
-A
See page 2-30 for Dimensions and Wiring Diagrams
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
SER-PRS = Series Programmed Rapid Start
PAGE 2-29
< 10
< 10
< 10
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
SER-IS = Series Instant Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp Certification
Starting
Line
Catalog
NOM
Qty. Method Volts
Number
120 B332I120HE
•
•
2 PAR-IS
277 B332I277HE
•
•
347
1
•
•
2 SER-IS
B332IHRVH-E
480
120
B232PUNVHP-A •
•
•
277
120
277 B232PUNVEL-A •
2
SER-PRS
120
277 B232PUNVHE-A •
120
B332PUNVHP-A •
•
•
277
F28T8 - Three Lamp Applications
120 B332I120RH-A
•
•
•
277 B332I277RH-A
•
•
•
120
B332IUNVHP-A •
•
•
277
120
B332IUNVEL-A •
•
3 PAR-IS 277
120 B332I120EL
•
•
277 B332I277EL
•
•
120
B332IUNVHE-A •
•
277
120 B332I120HE
•
•
277 B332I277HE
•
•
120
B332IUNVHEH-A •
•
277
347
3 SER-IS
B332IHRVHB-E •
•
480
347 B432I347RH
•
347 B432I347HP
•
120
B432IUNVHP-A •
•
•
277
120
B432IUNVEL-A •
•
277
277 B432I277EL
•
•
120
B432IUNVHE-A •
•
277
277 B432I277HE
•
•
120
B332PUNVHP-A •
•
•
277
3 SER-PRS
120
B432PUNVHP-A •
•
•
277
F28T8 - Four Lamp Applications
347 B432I347HP
•
347 B432I347RH
•
120
B432IUNVHP-A •
•
•
277
120
B432IUNVEL-A •
•
277
120 B432I120EL
•
•
277 B432I277EL
•
•
4 PAR-IS 120
B432IUNVHE-A •
•
277
120 B432I120HE
•
•
277 B432I277HE
•
•
277 B432I277HEH
•
•
120
4 SER-PRS
B432PUNVHP-A •
•
•
277
F32T8ES
TRIAD® ELECTRONIC BALLASTS
&
FOR F32T8ES AND F28T8 LAMPS
F28T8
Overall Dimensions
Draw #
L
ST
-A
-E
9.50”
9.50”
16.88”
W
2.40”
1.70”
1.74”
Mounting Dimensions
H
M
X
1.55”
1.18”
1.18”
8.89”
8.89”
16.28”
WIRING DIAGRAMS
1.69”
1.69”
---
DIAGRAM 1
For three lamp operation, cap any
blue lead, insulate to 600V
Fluorescent-Electronic
ST
DIAGRAM 7a
DIAGRAM 2
-A, -E
For Three Lamp Application, Individually
cap brown leads, Insulate to 600V
DIAGRAM 8
DIAGRAM 3
For Two Lamp operation, individually
cap yellow leads, Insulate to 600V
DIAGRAM 3a
Line
Black
White
BALLAST
DIAGRAM 23
Blue
Blue
Blue
Red
LAMP
LAMP
LAMP
For Two Lamp operation,
Insulate one blue lead to 600V
DIAGRAM 6
Line
DIAGRAM 30
Blue
Black
White
BALLAST
Yellow
Yellow
Blue
Red
Red
LAMP
LAMP
LAMP
LAMP
For Three Lamp Operation,
Insulate one blue lead to 600V
DIAGRAM 7
PAGE 2-30
DIAGRAM 46
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (1), (2), AND (3) F40T8 LAMPS
F40T8
• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
• 1-3 Lamp Applications
Ballast
Ballast
Min. F/C
Factor Efficacy THD Start Wiring
(BF) Factor (BEF) %
Temp Diag. Dim.
0.83
0.83
< 15
< 15
50/10
50/10
1
1
-A
-A
0.85
2.37
2.24
2.30
2.36
< 10
32/0
1
-B
0.76
2.38
< 10
0/-18
1
-A
0.86
2.46
< 10
0/-18
1
-A
0.91
0.91
0.95
1.03
1.03
1.02
0.86
1.03
1.02
< 25
< 25
< 20
< 25
< 25
<10
< 10
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
3a
3a
3a
3a
3a
3a
3a
-A
-A
-A
-A
-A
-A
ST
< 10
< 20
32/0
0/-18
3a
3a
-B
-A
0.99
0.71
0.84
1.05
0.87
2.28
2.28
2.50
2.29
2.29
2.27
2.26
2.40
2.45
2.27
2.30
2.36
2.37
2.45
2.33
2.40
2.84
2.69
1.98
< 10
0/-18
22
-C
< 10
0/-18
30
-A
< 10
0/-18
30
-A
< 10
0/-18
37
ESA
< 10
0/-18
37
ESA
0.91
0.87
0.89
0.82
0.96
1.00
0.82
0.95
0.89
0.99
1.26
1.20
1.23
1.24
1.18
1.17
1.22
1.19
1.22
1.23
1.31
1.35
1.29
1.32
1.25
1.25
< 10
< 20
< 20
< 20
< 20
< 20
< 10
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
14
6
6
6
6
6
6
ST
-A
-A
ST
-A
-A
ST
< 10
0/-18
6
-A
< 10
0/-18
6
-A
< 10
0/-18
6
-A
< 10
0/-18
6
-A
0.84
0.81
0.90
0.90
0.81
0.92
0.94
0.86
0.96
0.84
0.81
0.80
0.83
0.81
0.81
0.84
0.84
0.86
0.89
0.91
0.86
0.90
< 20
< 20
< 10
< 10
< 10
0/-18
0/-18
0/-18
0/-18
0/-18
7a
7
7a
7a
7
-A
ST
-A
-A
ST
< 10
0/-18
7a
-A
< 10
0/-18
24
-D
< 10
0/-18
7a
-A
< 10
0/-18
7a
-A
See page 2-32 for Dimensions and Wiring Diagrams
PAGE 2-31
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp Certification
Line
Input Power
Starting
Line
Catalog
Current Power Factor
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF)
F40T8 - One Lamp Applications
120 B132I120RH-A
•
•
•
0.30
35 > .96
277 B132I277RH-A
•
•
0.13
37 > .95
120
0.31
37
B132IUNVHP-B •
•
> .95
277
0.13
36
120
0.25
> .98
B132IUNVEL-A •
•
32
277
0.13
> .95
120
0.30
> .98
B132IUNVHE-A •
•
35
277
0.14
> .95
120 B232I120L-A
•
•
0.34
40 > .95
277 B232I277L-A
•
•
0.15
40 > .95
347 B232I347L-A
•
0.11
38 > .98
1
IS
120 B232I120RH-A
•
•
•
0.38
45 > .95
277 B232I277RH-A
•
•
•
0.17
45 > .95
347 B232I347HP-A
•
0.13
45 > .98
347 B232I347HPL
•
0.11
38 > .98
120
0.36
43 > .99
B232IUNVHP-B •
•
•
277
0.15
42 > .98
347 B232I347RH-A
•
0.13
45 > .98
120
0.37
43
B232IUNV-C
•
•
> .98
277
0.16
42
120
0.25
30
B232PUNVEL-A •
> .90
277
0.11
29
120
0.30
36
B232PUNVHE-A •
> .90
1
PRS
277
0.13
35
120
0.31
37
ES4800A
•
•
> .97
277
0.14
39
347 ES1679A
•
0.13
44 > .97
F40T8 - Two Lamp Applications
347 B259I347HP
•
0.22
76 > .98
120 B332I120L-A
•
•
0.60
71 > .98
277 B332I277L-A
•
•
0.26
72 > .98
347 B332I347L
•
0.20
69 > .99
120 B332I120RH-A
•
•
•
0.73
82 > .98
277 B332I277RH-A
•
•
•
0.31
82 > .98
2 PAR-IS 347 B332I347HPL
•
0.20
69 > .99
120
0.65
78 > .99
B332IUNVHP-A •
•
•
277
0.29
77 > .95
120
0.57
68 > .99
B332IUNVEL-A •
•
277
0.25
66 > .98
120
0.64
77 > .99
B332IUNVHE-A •
•
277
0.27
75 > .98
120
0.84
101
B332IUNVHEH-A •
•
> .95
277
0.36
101
F40T8 - Three Lamp Applications
120 B432I120L-A
•
•
0.84
100 > .98
347 B432I347L
•
0.29
100 > .99
120 B432I120RH-A
•
•
•
0.93
112 > .99
277 B432I277RH-A
•
•
•
0.40
109 > .99
347 B432I347HPL
•
0.29
100 > .99
120
0.95
114 > .99
3 PAR-IS
B432IUNVHP-A •
•
•
277
0.41
109 > .98
120
0.94
112
B432IUNV-D
•
•
> .98
277
0.40
109
120
0.81
97 > .99
B432IUNVEL-A •
•
277
0.35
94 > .98
120
0.93
111 > .99
B432IUNVHE-A •
•
277
0.39
107 > .98
TRIAD® ELECTRONIC BALLASTS
F40T8
FOR F40T8 LAMPS
Overall Dimensions
Draw #
L
ST
-A
-B
-C
-D
ESA
9.50”
9.50”
9.50”
14.25”
16.88”
9.50”
W
2.40”
1.70”
1.50”
1.18”
1.18”
1.56”
Mounting Dimensions
H
M
X
1.55”
1.18”
1.00”
1.00”
1.00”
1.00”
8.89”
8.89”
8.89”
13.75”
16.20”
8.88”
WIRING DIAGRAMS
1.69”
1.69”
0.88”
----0.78”
Line
Blue
Black
White
Yellow
Yellow
BALLAST
Blue
Red
Red
LAMP
LAMP
LAMP
LAMP
For Three Lamp Operation,
Insulate one blue lead to 600V
Fluorescent-Electronic
DIAGRAM 1
DIAGRAM 7
-A, -B, ESA
ST
-C, -D
For three lamp operation, cap any
blue lead, insulate to 600V
DIAGRAM 3a
DIAGRAM 7a
Line
Black
White
BALLAST
Blue
Blue
Blue
Red
LAMP
LAMP
LAMP
For Two Lamp Operation,
Insulate one blue lead to 600V
DIAGRAM 14
DIAGRAM 6
DIAGRAM 22
DIAGRAM 24
DIAGRAM 37
PAGE 2-32
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
• Instant Starting Options
FOR (1) AND (2)
F48T8, F72T8, F96T8 AND F96T8ES LAMPS
• 8’ T8 SLIMLINE
• 1-2 Lamp Applications
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
ST
SL
-A
9.50”
11.75”
9.50”
W
2.40”
3.13”
1.70”
Mounting Dimensions
H
M
X
1.55”
1.78”
1.18”
8.89”
11.14”
8.89”
1.07
1.07
3.15
3.06
< 10
< 10
0/-18
0/-18
14
14
ST
ST
0.90
0.90
1.61
1.64
< 10
< 10
0/-18
0/-18
14
14
ST
ST
1.05
1.05
2.10
2.06
< 10
< 10
0/-18
0/-18
14
14
ST
ST
0.88
0.88
1.05
1.07
< 10
< 10
0/-18
0/-18
14
14
ST
ST
0.88
0.88
1.05
1.05
0.92
0.92
1.08
1.05
1.05
1.05
1.52
1.52
1.54
1.54
1.53
1.53
1.50
1.52
1.54
1.53
1.52
< 20
< 20
< 25
< 20
< 10
< 10
50/10
50/10
50/10
50/10
50/10
50/10
13
13
14
14
14
14
ST
ST
ST
ST
ST
ST
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
14
14
13
13
-A
ST
ST
ST
0.88
0.88
1.18
1.18
0.78
0.78
0.88
0.89
0.88
0.88
0.79
0.79
0.79
0.79
0.78
0.78
0.78
0.80
0.79
0.81
0.83
< 20
< 20
< 20
< 20
< 10
< 10
50/10
50/10
32/0
32/0
50/10
50/10
14
14
14
14
14
14
ST
ST
SL
SL
ST
ST
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
14
14
14
14
-A
ST
ST
ST
1.05
1.05
1.66
1.66
< 10
< 10
60/16
60/16
13
13
ST
ST
1.18
1.18
0.88
0.88
0.83
0.86
0.86
0.88
< 20
< 20
< 10
< 10
60/16
60/16
60/16
60/16
14
14
14
14
SL
SL
ST
ST
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
WIRING DIAGRAMS
1.69”
2.00”
1.69”
DIAGRAM 13
ST, SL
Ballast
Ballast
Min. F/C
Factor Efficacy THD Start Wiring
(BF) Factor (BEF) %
Temp Diag. Dim.
-A
For One Lamp Operation, Insulate one blue
lead to 600V
DIAGRAM 14
PAGE 2-33
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Overall Dimensions
Draw #
L
SLIMLINE
• High Performance
Models
Lamp Certification
Line
Input Power
Starting
Line
Catalog Current Power Factor
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF)
F48T8 - One Lamp Applications
120 B259I120HE
•
•
0.29
34 > .98
1
IS
277 B259I277HE
•
•
0.16
35 > .97
F48T8 - Two Lamp Applications
120 B259I120HE
•
•
0.47
56 > .99
2 PAR-IS
277 B259I277HE
•
•
0.20
55 > .97
F72T8 - One Lamp Applications
120 B259I120HE
•
•
0.42
50 > .99
1
IS
120 B259I277HE
•
•
0.19
51 > .97
F72T8 - Two Lamp Applications
277 B259I120HE
•
•
0.71
84 > .99
2 PAR-IS
277 B259I277HE
•
•
0.30
82 > .97
F96T8 - One Lamp Applications
120 B159I120RH
•
•
0.52
58 > .96
277 B159I277RH
•
•
0.22
58 > .96
120 B259I120RH
•
•
•
0.62
68 > .97
277 B259I277RH
•
•
•
0.26
68 > .97
1
IS
120 B259I120HPL
•
•
0.51
60 > .98
277 B259I277HPL
•
•
0.22
60 > .98
120
0.60
72 > .99
B259IUNVHP-A •
•
•
277
0.26
71 > .98
347 B259I347HP
•
0.20
68 > .97
120 B259I120HE
•
•
0.58
69 > .97
277 B259I277HE
•
•
0.25
69 > .97
F96T8 - Two Lamp Applications
120 B259I120RH
•
•
•
0.95
112 > .98
277 B259I277RH
•
•
•
0.41
112 > .98
120 B259I120RHH
•
•
1.30
150 > .98
277 B259I277RHH
•
•
0.56
150 > .98
120 B259I120HPL
•
•
0.84
100 > .98
2 PAR-IS
277 B259I277HPL
•
•
0.36
100 > .98
120
0.95
113 > .99
B259IUNVHP-A •
•
•
277
0.40
110 > .98
347 B259I347HP
•
0.33
113 > .99
120 B259I120HE
•
•
0.92
108 > .99
277 B259I277HE
•
•
0.38
106 > .99
F96T8ES - One Lamp Applications
120 B259I120HE
•
•
0.53
63 > .97
1 PAR-IS
277 B259I277HE
•
•
0.23
63 > .97
F96T8ES - Two Lamp Applications
120 B259I120RHH
•
•
1.20
142 > .98
277 B259I277RHH
•
•
0.50
138 > .98
2 PAR-IS
120 B259I120HE
•
•
0.85
102 > .99
277 B259I277HE
•
•
0.36
100 > .99
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
T8
Slimline Lamps
T8HO
• Instant Starting Options
• 1-2 Lamp Applications
High Output Lamps
TRIAD® ELECTRONIC BALLASTS
FOR (1) AND (2)
F48T8HO, F60T8HO, F72T8HO AND
F96T8HO LAMPS
• 4-8’ T8 High Output
Fluorescent-Electronic
Lamp Certification
Line
Input Power
Starting
Line
Catalog Current Power Factor
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF)
F48T8HO - One Lamp Applications
120 B286I120RH
•
•
•
0.47
48 > .90
1
IS
277 B286I277RH
•
•
•
0.20
47 > .90
F60T8HO - One Lamp Applications
120 B286I120RH
•
•
•
0.56
60 > .90
1
IS
277 B286I277RH
•
•
•
0.23
57 > .90
F72T8HO - One Lamp Applications
120 B286I120RH
•
•
•
0.64
71 > .90
1
IS
277 B286I277RH
•
•
•
0.26
67 > .90
F96T8HO - One Lamp Applications
120 B286I120RH
•
•
•
0.79
92 > .90
1
IS
277 B286I277RH
•
•
•
0.32
87 > .90
F48T8HO - Two Lamp Applications
120 B286I120RH
•
•
•
0.70
80 > .95
2 PAR-IS
277 B286I277RH
•
•
•
0.30
77 > .90
F60T8HO - Two Lamp Applications
120 B286I120RH
•
•
•
0.85
99 > .95
2 PAR-IS
277 B286I277RH
•
•
•
0.36
96 > .95
F72T8HO - Two Lamp Applications
120 B286I120RH
•
•
•
1.00
117 > .95
2 PAR-IS
277 B286I277RH
•
•
•
0.42
114 > .95
F96T8HO - Two Lamp Applications
120 B286I120RH
•
•
•
1.30
151 > .95
2 PAR-IS
277 B286I277RH
•
•
•
0.53
144 > .95
SL
11.75”
W
3.13”
Mounting Dimensions
H
M
X
1.78”
1.00
1.00
2.08
2.13
< 30 -20/-29
< 30 -20/-29
3
3
SL
SL
0.99
0.98
1.65
1.72
< 30 -20/-29
< 30 -20/-29
3
3
SL
SL
0.98
0.98
1.38
1.46
< 30 -20/-29
< 30 -20/-29
3
3
SL
SL
0.96
0.93
1.04
1.07
< 25 -20/-29
< 25 -20/-29
3
3
SL
SL
0.85
0.84
1.06
1.09
< 25 -20/-29
< 25 -20/-29
3
3
SL
SL
0.85
0.84
0.86
0.88
< 20 -20/-29
< 20 -20/-29
3
3
SL
SL
0.85
0.84
0.73
0.74
< 20 -20/-29
< 20 -20/-29
3
3
SL
SL
0.81
0.81
0.54
0.56
< 20 -20/-29
< 20 -20/-29
3
3
SL
SL
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
Overall Dimensions
Draw #
L
Ballast
Ballast
Min. F/C
Factor Efficacy THD Start Wiring
(BF) Factor (BEF) %
Temp Diag. Dim.
11.14”
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
WIRING DIAGRAMS
2.00”
SL
For One Lamp Operation, Insulate one blue lead to 600V
DIAGRAM 3
PAGE 2-34
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® T5 ELECTRONIC
BALLASTS
FOR F8, F13, F14, F21 AND F24 LAMPS
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
0.18
10
> .50
1.30
13.00
< 150 0/-18
47
CBT
0.34
22
> .50
1.30
5.91
< 150 0/-18
47
CBT
0.25
15
> .50
1.10
9.33
< 150 0/-18
47
CBT
0.48
28
> .50
1.10
3.93
< 150 0/-18
48
CBT
0.15
0.07
0.14
0.07
0.15
0.07
0.25
18
16
17
19
20
16
> .98
> .90
> .98
> .85
1.05
0.89
1.00
0.97
5.83
5.56
5.24
5.26
5.00
6.06
< 10
< 15
< 15
< 20
0/-18
37
-C
0/-18
37
-C
< 10
0/-18
< 150 0/-18
40
ESX
0.28
0.13
0.24
0.11
0.25
0.11
0.31
0.13
0.46
34
29
31
37
36
30
> .98
> .95
> .99
> .90
> .99
> .98
> .99
> .98
> .50
1.00
2.94
< 10
37
-C
0.89
3.07
< 10
< 15
0/-18
0/-18
37
-C
0.95
3.06
< 10
0/-18
37
-D
< 10
0/-18
37
-D
0.21
0.10
0.19
0.09
0.20
0.09
0.36
25
22
23
26
> .98
> .95
> .99
> .90
0/-18
37
-C
0/-18
37
-C
< 10
0/-18
40
47
CBT
0.41
0.18
0.35
0.16
0.37
0.16
0.44
0.19
49
48
42
44
52
51
> .98
< 10
0/-18
37
-C
< 10
0/-18
37
-C
0.40
26
25
> .97
> .50
47 CBT
3.12
3.19
3.23
< 150 0/-18
0.89
4.12
4.05
3.87
< 10
< 15
< 10
< 15
1.00
3.85
1.00
> .99
> .95 0.89
> .99
> .98 0.95
> .99
> .98 1.15
2.04
2.08
2.12
2.21
2.25
< 10
0/-18
37
-D
< 10
0/-18
37
-D
> .50
3.85
< 150 0/-18
47
CBT
> .97
> .50
1.15
0.97
1.03
1.15
1.00
4.60
2.16
< 150 0/-18
48 CBT
ESX
See page 2-38 for Dimensions and Wiring Diagrams
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAGE 2-35
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp Certification
Starting
Line
Catalog
NOM
Qty. Method Volts
Number
F8T5 - One Lamp Applications
1
RS
120 CBT113L-120 n •
•
F8T5 - Two Lamp Applications
2
RS
120 CBT213L-120 n •
•
F13T5 - One Lamp Applications
1
RS
120 CBT113L-120 n •
•
F13T5 - Two Lamp Applications
2 SER-RS 120 CBT213L-120 n •
•
F14T5 - One Lamp Applications
120
•
•
•
277 B228PUNV-C
120
PRS
•
1
277 B228PUNV90-C •
120
ES4528X
•
•
277
1
RS
120 CBT113L-120 n •
•
F14T5 - Two Lamp Applications
120
•
•
•
277 B228PUNV-C
120
•
277 B228PUNV90-C •
120
•
2 SER-PRS
277 B228PUNV95-D •
120
•
277 B228PUNV115-D •
2 SER-RS 120 CBT213L-120 n •
•
F21T5 - One Lamp Applications
120
•
•
•
277 B228PUNV-C
120
PRS
•
•
1
277 B228PUNV90-C
120
•
•
277 ES4528X
RS
120 CBT213L-120 n •
•
F21T5 - Two Lamp Applications
120
•
•
•
277 B228PUNV-C
120
•
•
277 B228PUNV90-C
2 SER-PRS
120
•
277 B228PUNV95-D •
120
•
277 B228PUNV115-D •
F24T5 - One Lamp Applications
1
RS
120 CBT126L-120 n •
•
n Add “B” for Bottom Exit or “S” for Side Exit
or “BS” for Bottom Exit with 2” O.C. screw studs.
T5
• Multiple Lamp Operation
• Rapid and Programmed Rapid
Starting Options
• T5 Ballasts meet ANSI requirement for
end-of-lamp life safety shutdown
• Super Low Profile Designs
• 1-2 Lamp Applications
Fluorescent-Electronic
T5
TRIAD® T5 ELECTRONIC
BALLASTS
• Multiple Lamp Operation
• Rapid and Programmed Rapid
Starting Options
• T5 Ballasts meet ANSI requirement for
end-of-lamp life safety shutdown
• Super Low Profile Designs
• 1-2 Lamp Applications
Lamp Certification
Starting
Line
Catalog
NOM
Qty. Method Volts
Number
F28T5 - One Lamp Applications
120
•
•
•
277 B228PUNV-C
120
PRS
•
•
1
277 B228PUNV90-C
120
ES4528X
•
•
277
1
RS
120 CBT213L-120 n •
•
F28T5 - Two Lamp Applications
120
•
•
•
277 B228PUNV-C
120
•
•
277 B228PUNV90-C
2
SER-PRS
120
B228PUNV95-D
•
•
277
120
•
277 B228PUNV115-D •
F35T5 - One Lamp Applications
120
PRS
•
•
1
277 ES4528X
n Add “B” for Bottom Exit or “S” for Side Exit
or “BS” for Bottom Exit with 2” O.C. screw studs.
FOR F28 AND F35T5 LAMPS
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
0.28
0.12
0.11
0.25
0.27
0.12
0.45
33
29
30
> .98
> .95
> .99
> .90
34
> .97
30
0.55
0.23
0.48
0.21
0.50
0.21
0.59
0.25
66
64
58
56
58
57
69
68
0.34
0.15
42
> .50
1.00
3.03
0.90
3.10
3.00
1.00
2.94
0.96
3.20
> .99
> .98
> .99
> .98
1.00
0.90
0.95
1.15
1.52
1.56
1.55
1.61
1.64
1.67
1.67
1.69
> .97
1.00
2.38
> .98
> .98
< 10
0/-18
37
-C
0/-18
37
-C
< 10
0/-18
< 150 0/-18
40
47
ESX
CBT
< 10
0/-18
37
-C
< 10
0/-18
37
-C
< 10
0/-18
37
-D
< 10
0/-18
37
-D
< 10
0/-18
40
ESX
< 10
< 15
See page 2-38 for Dimensions and Wiring Diagrams
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAGE 2-36
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD T5HO ELECTRONIC
BALLASTS
®
FOR F24, F39 AND
F54 T5HO LAMPS
• Multiple Lamp Operation
• Programmed Rapid and
Instant Starting Models
• T5HO Ballasts meet ANSI
requirements for end-of-lamp
life safety shutdown
• Super Low Profile Designs
• 1-4 Lamp Applications
Ballast
Ballast
Min. F/C
Factor Efficacy THD Start Wiring
(BF) Factor (BEF) %
Temp Diag. Dim.
1.06
3.79
< 10
0/-18
37
-C
1.00
1.89
1.92
< 10
0/-18
37
-C
1.15
1.95
< 10
0/-18
37
-D
0.95
2.32
2.38
< 10
0/-18
37
-C
1.10
2.34
< 10
0/-18
37
-D
1.00
1.12
1.14
< 10
0/-18
37
-D
< 10
< 15
0/-18
42
-E
< 10
0/-18
37
-D
1.02
1.02
1.55
1.62
1.65
1.62
1.65
1.59
1.00
1.00
1.00
1.00
1.00
1.00
0.83
0.84
0.83
0.85
0.83
0.85
0.83
0.83
0.86
0.82
0.83
1.05
1.05
0.58
0.59
0.57
0.58
1.00
1.00
0.42
0.43
0.43
0.44
1.00
1.15
1.16
1.02
1.02
< 10
0/-18
37
-D
< 10
0/-18
4b
-D
< 10
0/-18
41
-E
< 10
0/-18
37
-D
< 10
0/-18
37
-D
< 10
< 10
< 15
< 10
< 15
0/-18
4b
-D
0/-18
44
-E
0/-18
44
-E
< 10
0/-18
44
-E
< 10
0/-18
44
-E
< 10
0/-18
44
-E
< 10
0/-18
44
-E
< 10
0/-18
43
ESK
See page 2-38 for Dimensions and Wiring Diagrams
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAGE 2-37
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp Certification
Line
Input Power
Starting
Line
Catalog Current Power Factor
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF)
F24T5HO - One Lamp Applications
120
0.23
> .98
1
PRS
B224PUNV-C
•
•
•
28
277
0.10
> .95
F24T5HO - Two Lamp Applications
120
0.45
53
B224PUNV-C
•
•
•
> .98
277
0.19
52
2 SER-PRS
120
0.51
> .98
B239PUNV-D
•
•
•
59
277
0.22
> .95
F39T5HO - One Lamp Applications
120
0.34
41
B224PUNV-C
•
•
•
> .98
277
0.15
40
1
PRS
120
0.39
> .98
B239PUNV-D
•
•
•
47
277
0.18
> .95
F39T5HO - Two Lamp Applications
120
0.75
89
2 SER-PRS
B239PUNV-D
•
•
•
> .98
277
0.32
88
F54T5HO - One Lamp Applications
347
0.19
> .98
B254PHRVHB-E •
•
66
480
0.15
> .90
120
0.52
63 > .99
B254PUNV-D
•
•
•
1
PRS
277
0.23
62 > .95
120
0.52
63 > .99
B254PUNVHB-D •
•
•
277
0.23
62 > .95
347 B254P347-D
•
0.19
64 > .95
F54T5HO - Two Lamp Applications
347
0.35
120 > .98
B254PHRVHB-E •
•
480
0.26
119 > .95
120
1.03
120 > .99
B254PUNV-D
•
•
•
277
0.43
117 > .98
120
1.03
120 > .99
B254PUNVHB-E •
•
•
2 SER-PRS 277
0.43
117 > .98
347 B254P347-D
•
0.35
120 > .98
120
1.01
121
B454PUNV-E
•
•
> .95
277
0.44
116
120
1.01
122
B454PUNVHB-E •
•
> .95
277
0.44
121
F54T5HO - Three Lamp Applications
120
1.52
181 > .98
B454PUNV-E
•
•
277
0.66
178 > .95
3 SER-PRS
120
1.52
184 > .98
B454PUNVHB-E •
•
277
0.66
182 > .95
F54T5HO - Four Lamp Applications
120
2.01
240 > .98
B454PUNV-E
•
•
277
0.86
234 > .99
4 SER-PRS
120
1.96
235 > .98
B454PUNVHB-E •
•
277
0.84
229 > .99
F80T5HO - One Lamp Applications
120
0.73
87
1
PRS
ES4515K
•
•
> .97
277
0.32
86
T5HO
T5
TRIAD® T5 & T5HO ELECTRONIC
BALLASTS
&
T5HO
Overall Dimensions
Draw #
L
-C
CBT
-D
-E
ESK
ESX
14.25”
3.86”
16.88”
16.88”
16.65”
14.13”
W
1.18”
2.00”
1.18”
1.74”
1.24”
1.24”
Mounting Dimensions
H
M
X
1.00”
1.00”
1.00”
1.18”
1.00”
0.73”
13.75”
3.50”
16.20”
16.28”
16.30”
13.78”
—
—
—
—
—
—
WIRING DIAGRAMS
DIAGRAM 4b
Fluorescent-Electronic
-C, -D
CBT
-E, ESK, ESX
DIAGRAM 37
T5 ballasts incorporate poke
in connectors, for easy installation
DIAGRAM 40
DIAGRAM 43
DIAGRAM 41
DIAGRAM 42
For one lamp operation, individually cap
yellow and yellow/black leads,
insulate to 600V.
DIAGRAM 44
DIAGRAM 47
DIAGRAM 48
PAGE 2-38
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (1), (2) AND (3)
F30T12, F30T12ES, & (2)F32T12 LAMPS
ST
-A
9.50”
9.50”
W
2.40”
1.70”
Mounting Dimensions
H
M
X
1.55”
1.18”
8.89”
8.89”
T12 Straight Lamps
• 1-3 Lamp Applications
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
0.26
0.11
0.33
0.14
30
30
37
37
> .95
> .95
> .95
> .95
0.91
0.91
1.05
1.05
3.03
3.03
2.84
2.84
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
2
2
4
4
ST
ST
ST
ST
0.51
0.50
0.22
59
60
60
> .95
> .95
> .95
0.92
0.92
0.92
1.56
1.53
1.53
< 20
< 10
< 10
50/10
50/10
50/10
4
4
4
ST
ST
ST
0.75
0.33
90
90
> .98
> .98
0.91
0.91
1.01
1.01
< 10
< 10
50/10
50/10
5
5
ST
ST
0.24
0.10
0.30
0.13
27
27
33
33
> .97
> .97
> .95
> .95
0.86
0.86
1.00
1.00
3.19
3.19
3.03
3.03
< 10
< 10
< 10
< 10
60/16
60/16
60/16
60/16
2
2
4
4
ST
ST
ST
ST
0.46
0.20
53
53
> .98
> .98
0.88
0.88
1.66
1.66
< 10
< 10
60/16
60/16
4
4
ST
ST
0.64
0.28
76
76
> .98
> .98
0.88
0.88
1.16
1.16
< 10
< 10
60/16
60/16
5
5
ST
ST
0.48
56
> .98
0.90
1.61
< 25
50/10
2
-A
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
Overall Dimensions
Draw #
L
• Standard & High
Performance Models
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
WIRING DIAGRAMS
1.69”
1.69”
DIAGRAM 2
ST
For One lamp Operation, Individually Cap
blue leads, Insulate to 600V
DIAGRAM 4
-A
DIAGRAM 5
PAGE 2-39
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp Certification
Starting
Line
Catalog
NOM
Qty. Method Volts
Number
F30T12 - One Lamp Applications
120 B140R120HP
•
•
277 B140R277HP
•
•
1
RS
120 B240R120HP
•
•
•
277 B240R277HP
•
•
F30T12 - Two Lamp Applications
120 B240R120RH
•
•
2 PAR-RS 120 B240R120HP
•
•
•
277 B240R277HP
•
•
F30T12 - Three Lamp Applications
120 B340R120HP
•
•
3 PAR-RS
277 B340R277HP
•
•
F30T12ES - One Lamp Applications
120 B140R120HP
•
•
277 B140R277HP
•
•
1
RS
120 B240R120HP
•
•
•
277 B240R277HP
•
•
F30T12ES - Two Lamp Applications
120 B240R120HP
•
•
•
2 PAR-RS
277 B240R277HP
•
•
F30T12ES - Three Lamp Applications
120 B340R120HP
•
•
3 PAR-RS
277 B340R277HP
•
•
F32T12 - Two Lamp Applications
2 SER-RS 120 B234SR120M-A •
•
F30T12,
F30T12ES,
F32T12
• Rapid Starting Options
F40T12
TRIAD® ELECTRONIC BALLASTS
• Standard & High
Performance Models
&
F34T12ES
FOR (1) , (2) AND (3)
F40T12 AND F34T12ES LAMPS
• Rapid Starting Options
T12 Straight Lamps
• 1-3 Lamp Applications
T12 U-Shaped Lamps
Fluorescent-Electronic
Lamp Certification
Line
Input Power
Starting
Line
Catalog Current Power Factor
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF)
F40T12 - One Lamp Applications
120 B140R120HP
•
•
0.33
38 > .99
277 B140R277HP
•
•
0.14
38 > .99
120 B134R120M-A
•
•
0.36
36 > .90
1
RS
277 B234SR277M-A •
•
0.17
42 > .88
120 B240R120RH
•
•
0.41
46 > .90
120 B240R120HP
•
•
•
0.42
46 > .98
277 B240R277HP
•
•
0.18
46 > .98
F40T12 - Two Lamp Applications
120 B240R120RH
•
•
0.62
73 > .98
120 B240R120HP
•
•
•
0.65
75 > .99
2 PAR-RS 277 B240R277HP
•
•
0.28
74 > .99
120 B340R120HP
•
•
0.70
84 > .98
277 B340R277HP
•
•
0.31
84 > .98
2 SER-RS 120 B234SR120M-A •
•
0.63
71 > .90
277 B234SR277M-A •
•
0.26
70 > .90
F40T12 - Three Lamp Applications
120 B340R120HP
•
0.94
113 > .99
3 PAR-RS
277 B340R277HP
•
•
0.41
113 > .99
F34T12ES - One Lamp Applications
120 B140R120HP
•
•
0.28
32 > .98
277 B140R277HP
•
•
0.12
32 > .98
120 B134R120M-A
•
•
0.30
31 > .90
1
RS
277 B234SR277M-A •
•
0.15
25 > .80
120 B240R120RH
•
•
0.36
39 > .89
120 B240R120HP
•
•
•
0.35
39 > .98
277 B240R277HP
•
•
0.15
39 > .98
F34T12ES - Two Lamp Applications
120 B240R120RH
•
•
0.53
62 > .95
2 PAR-RS 120 B240R120HP
•
•
•
0.54
63 > .99
277 B240R277HP
•
•
0.23
63 > .99
2 SER-RS 120 B234SR120M-A •
•
0.49
59 > .90
277 B234SR277M-A •
•
0.23
60 > .90
F34T12ES - Three Lamp Applications
120 B340R120HP
•
•
0.78
93 > .99
3 PAR-RS
277 B340R277HP
•
•
0.34
93 > .99
Overall Dimensions
Draw #
L
ST
-A
9.50”
9.50”
W
2.40”
1.70”
Mounting Dimensions
H
M
X
1.55”
1.18”
8.89”
8.89”
0.88
0.88
0.86
0.94
1.09
1.02
1.02
2.32
2.32
2.39
2.24
2.37
2.22
2.22
< 10
< 10
< 30
< 30
< 20
< 10
< 10
50/10
50/10
50/10
50/10
50/10
50/10
50/10
2
2
2
4
4
4
4
ST
ST
-A
-A
ST
ST
ST
0.89
0.90
0.90
1.04
1.04
0.90
0.87
1.22
1.20
1.22
1.24
1.24
1.27
1.24
< 20
< 10
< 10
< 10
< 10
< 30
< 30
50/10
50/10
50/10
50/10
50/10
50/10
50/10
4
4
4
5
5
30
4
ST
ST
ST
ST
ST
-A
-A
0.88
0.88
0.78
0.78
< 10
< 10
50/10
50/10
5
5
ST
ST
0.86
0.86
0.86
0.94
1.10
0.97
0.97
2.69
2.69
2.77
2.69
2.82
2.49
2.49
< 10
< 10
< 30
< 30
< 20
< 10
< 10
60/16
60/16
60/16
50/10
60/16
60/16
60/16
2
2
2
4
4
4
4
ST
ST
-A
-A
ST
ST
ST
0.89
0.86
0.86
0.86
0.87
1.44
1.37
1.37
1.46
1.45
< 20
< 10
< 10
< 30
< 30
60/16
60/16
60/16
60/16
50/10
4
4
4
30
4
ST
ST
ST
-A
-A
0.86
0.86
0.92
0.92
< 10
< 10
60/16
60/16
5
5
ST
ST
WIRING DIAGRAMS
1.69”
1.69”
DIAGRAM 2
ST
Ballast
Ballast
Min. F/C
Factor Efficacy THD Start Wiring
(BF) Factor (BEF) %
Temp Diag. Dim.
-A
For One Lamp Applications, individually cap
blue leads, Insulate fo 600V
DIAGRAM 4
DIAGRAM 5
DIAGRAM 30
PAGE 2-40
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
• Standard & High
Performance Models
FOR F48T12, F48T12ES, F60T12, F64T12 &
F72T12 LAMPS
• Instant Starting Options
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
SL
-A
ST
ST
11.75”
9.50”
9.50”
W
3.13”
1.70”
2.40”
Mounting Dimensions
H
M
X
1.78”
1.18”
1.55”
SL
11.14”
8.89”
8.89”
Ballast
Ballast
Min. F/C
Factor Efficacy THD Start Wiring
(BF) Factor (BEF) %
Temp Diag. Dim.
1.10
2.34
0.92
0.90
0.95
1.21
1.32
1.27
1.28
1.10
2.89
2.82
0.92
0.93
< 10
0/-18
14
SL
< 20
< 30
0/-18
50/10
14
14
ST
-A
< 10
0/-18
14
SL
< 10
60/16
14
SL
1.44
1.39
1.41
< 20
60/16
14
ST
< 10
60/16
14
SL
1.02
1.10
1.85
1.90
< 20
0/-18
14
ST
< 10
0/-18
14
SL
0.90
0.92
1.01
1.00
1.01
< 20
0/-18
14
ST
< 10
0/-18
14
SL
1.03
1.10
1.75
1.80
1.15
< 20
0/-18
14
ST
< 10
0/-18
14
SL
0.90
0.92
0.95
0.95
0.96
< 20
0/-18
14
ST
< 10
0/-18
14
SL
1.04
1.06
1.58
1.56
1.58
< 20
0/-18
14
ST
< 10
0/-18
14
SL
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
WIRING DIAGRAMS
2.00”
1.69”
1.69”
-A
PAGE 2-41
For One Lamp Operation, Insulate one blue lead to 600V
DIAGRAM 14
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Overall Dimensions
Draw #
L
SLIMLINE
• 1-2 Lamp Applications
Lamp Certification
Line
Input Power
Starting
Line
Catalog Current Power Factor
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF)
F48T12 - One Lamp Applications
1
IS
120
0.39
B260IUNVHP
•
•
47
> .95
277
0.18
F48T12 - Two Lamp Applications
120 B260I120RH
•
•
0.68
76 > .95
2 PAR-IS 120 B260I120M-A
•
•
0.62
68 > .90
120
0.61
75 > .98
B260IUNVHP
•
•
277
0.27
74 > .95
F48T12ES - One Lamp Applications
1
IS
120
0.32
38 > .98
B260IUNVHP
•
•
277
0.15
39 > .95
F48T12ES - Two Lamp Applications
120 B260I120RH
•
•
0.60
64 > .95
2 PAR-IS 120
0.57
67
B260IUNVHP
•
•
> .95
277
0.25
66
F60T12 - One Lamp Applications
120 B260I120RH
•
•
0.46
55 > .95
1 PAR-IS 120
0.49
> .98
B260IUNVHP
•
•
58
277
0.22
> .95
F60T12 - Two Lamp Applications
120 B260I120RH
•
•
0.74
89 > .95
2 PAR-IS 120
0.77
92
B260IUNVHP
•
•
> .98
277
0.33
91
F64T12 - One Lamp Applications
120 B260I120RH
•
•
0.49
59 > .95
1 PAR-IS 120
0.51
61 > .98
B260IUNVHP
•
•
277
0.35
96 > .95
F64T12 - Two Lamp Applications
120 B260I120RH
•
•
0.80
95 > .95
2 PAR-IS 120
0.81
97
B260IUNVHP
•
•
> .98
277
0.35
96
F72T12 - One Lamp Applications
120 B260I120RH
•
•
0.60
66 > .95
1
IS
120
0.55
68
B260IUNVHP
•
•
> .95
277
0.25
67
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
T12
Slimline Lamps
T12
Slimline Lamps
SLIMLINE
• Standard & High
Performance Models
TRIAD® ELECTRONIC BALLASTS
• Instant Starting Options
F72T12(cont.), F84T12, F96T12 & F96T12ES
LAMPS
• 1-2 Lamp Applications
Fluorescent-Electronic
Lamp Certification
Line
Input Power
Starting
Line
Catalog Current Power Factor
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF)
F72T12 - Two Lamp Applications
120 B260I120RH
•
•
0.92
107 > .95
2 PAR-IS 120 B260I120M-A
•
•
0.90
105 > .95
120
0.90
109
B260IUNVHP
•
•
> .99
277
0.39
107
F84T12 - One Lamp Applications
120 B260I120RH
•
•
0.63
74 > .95
1
IS
120
0.63
76
B260IUNVHP
•
•
> .98
277
0.28
75
F84T12 - Two Lamp Applications
120 B260I120RH
•
•
1.02
120 > .95
2 PAR-IS 120
1.03
123
B260IUNVHP
•
•
> .98
277
0.44
120
F96T12 - One Lamp Applications
120 B260I120RH
•
•
0.73
83 > .95
1
IS
120
0.70
85
B260IUNVHP
•
•
> .98
277
0.31
84
F96T12 - Two Lamp Applications
120 B260I120RH
•
•
1.16
133 > .95
2 PAR-IS 120
1.16
139
B260IUNVHP
•
•
> .99
277
0.50
137
F96T12ES - One Lamp Applications
120 B260I120RH
•
•
0.60
66 > .95
1
IS
120 B260I120M-A
•
•
0.61
66 > .90
120
0.59
72
B260IUNVHP
•
•
> .98
277
0.26
70
F96T12ES - Two Lamp Applications
120 B260I120RH
•
•
0.93
107 > .95
2 PAR-IS 120 B260I120M-A
•
•
0.90
105 > .95
120
0.96
112
B260IUNVHP
•
•
> .99
277
0.40
110
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
Overall Dimensions
Draw #
L
SL
-A
ST
11.75”
9.50”
9.50”
ST
W
3.13”
1.70”
2.40”
Mounting Dimensions
H
M
X
1.78”
1.18”
1.55”
11.14”
8.89”
8.89”
SL
Ballast
Ballast
Min. F/C
Factor Efficacy THD Start Wiring
(BF) Factor (BEF) %
Temp Diag. Dim.
0.90
0.90
0.91
0.84
0.86
0.83
0.85
< 20
< 30
0/-18
50/10
14
14
ST
-A
< 10
0/-18
14
SL
1.05
1.10
1.42
1.45
1.47
< 20
0/-18
14
ST
< 10
0/-18
14
-A
0.88
0.88
0.73
0.72
0.73
< 20
0/-18
14
ST
< 10
0/-18
14
-A
1.02
1.05
1.23
1.24
1.25
< 20
0/-18
14
ST
< 10
0/-18
14
SL
0.86
0.88
0.65
0.63
0.64
< 20
0/-18
14
ST
< 10
0/-18
14
SL
1.05
1.09
1.03
1.59
1.65
1.43
1.47
< 20
< 30
60/16
60/16
14
14
ST
-A
< 10
60/16
14
SL
0.88
0.88
0.88
0.82
0.84
0.79
0.80
< 20
< 30
60/16
60/16
14
14
ST
-A
< 10
60/16
14
SL
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
WIRING DIAGRAMS
2.00”
1.69”
1.69”
-A
For One Lamp Operation, Insulate one blue lead to 600V
DIAGRAM 14
PAGE 2-42
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR T12 HIGH
OUTPUT LAMPS
• Rapid Starting Options
• 2 Lamp Applications
ST
SL
9.50”
11.75”
ST
2.40”
3.13”
Mounting Dimensions
H
M
X
1.55”
1.78”
0.89
0.81
0.82
< 10 -20/-29
4
SL
0.89
0.66
0.67
< 10 -20/-29
4
SL
0.95
0.89
0.56
0.55
0.56
< 10 -20/-29
4
SL
< 10 -20/-29
4
SL
1.00
0.56
< 25
4
ST
0.89
0.89
0.48
0.48
0.49
< 10 - 20/-29
4
SL
< 10 -20/-29
4
SL
0.88
0.88
0.43
0.43
0.44
< 10 - 20/-29
4
SL
< 10 -20/-29
4
SL
0.88
0.51
< 10
60/16
4
SL
0.88
0.51
< 10
60/16
4
SL
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
W
Ballast
Ballast
Min. F/C
Factor Efficacy THD Start Wiring
(BF) Factor (BEF) %
Temp Diag. Dim.
8.89”
11.14”
50/10
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
WIRING DIAGRAMS
1.69”
2.00”
SL
DIAGRAM 4
PAGE 2-43
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp Certification
Line
Input Power
Starting
Line
Catalog
Current Power Factor
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF)
F48T12HO - Two Lamp Applications
120
0.92
110
2 SER-RS
B295SRUNVHP •
•
> .98
277
0.40
109
F60T12HO - Two Lamp Applications
120
1.11
134
2 SER-RS
B295SRUNVHP •
•
> .98
277
0.48
132
F72T12HO - Two Lamp Applications
120 B295SR120HP
•
•
1.40
169 > .99
2 SER-RS 120
1.40
162
B295SRUNVHPº •
•
> .99
277
0.61
160
F73T12/BL/HO - Two Lamp Applications
2 SER-RS 120 493B2
•
•
1.60
180 > .90
F84T12HO - Two Lamp Applications
120 B295SR120HP
•
•
1.60
185 > .99
2 SER-RS 120
1.60
176
B295SRUNVHPº •
•
> .99
277
0.69
173
F96T12HO - Two Lamp Applications
120 B295SR120HP
•
•
1.77
208 > .99
2 SER-RS 120
1.77
205
B295SRUNVHPº •
•
> .99
277
0.76
209
F96T12HOES - Two Lamp Applications
120 B295SR120HP
•
•
1.47
174 > .99
2 SER-RS 120
1.47
174
B295SRUNVHPº •
•
> .99
277
0.63
171
º Preliminary Data
Overall Dimensions
Draw #
L
T12HO
• High Performance
Models
Fluorescent-Electronic
T2
• Programmed Rapid
Starting Options
TRIAD® ELECTRONIC BALLASTS
• 1-2 Lamp Applications
FOR F6T2, F8T2, F11T2 AND F13T2 LAMPS
Lamp Certification
Line
Input Power
Starting
Line
Catalog Current Power Factor
NOM
Qty. Method Volts
Number (Amps) (Watts) (PF)
F6T2 - One And Two Lamp Applications
120
0.12
14
2 SER-PRS
ES1786X
•
•
> .97
277
0.07
15
120
0.07
8
1
PRS
ES1786X
•
•
> .97
277
0.05
9
F8T2 - One And Two Lamp Applications
120
0.17
20
2 SER-PRS
ES1786X
•
•
> .97
277
0.08
21
120
0.10
1
PRS
ES1786X
•
•
11 > .97
277
0.06
F11T2 - One And Two Lamp Applications
120
0.20
2 SER-PRS
ES1786X
•
•
26 > .97
277
0.09
120
0.12
1
PRS
ES1786X
•
•
15 > .97
277
0.07
F13T2 - One And Two Lamp Applications
120
0.27
31
2 SER-PRS
ES1786X
•
•
> .97
277
0.13
32
120
0.15
16
1
PRS
ES1786X
•
•
> .97
277
0.08
17
ESX
14.13”
W
1.24”
Mounting Dimensions
H
M
X
0.73”
1.00
1.00
7.14
6.67
12.50
11.11
1.00
< 10
0/-18
37
ESX
< 10
0/-18
37
ESX
5.00
4.76
< 10
0/-18
37
ESX
1.00
9.09
< 10
0/-18
37
ESX
1.00
3.85
< 10
0/-18
37
ESX
1.00
6.67
< 10
0/-18
37
ESX
1.00
1.00
3.23
3.13
6.25
5.88
< 10
0/-18
37
ESX
< 10
0/-18
37
ESX
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
Overall Dimensions
Draw #
L
Ballast
Ballast
Min. F/C
Factor Efficacy THD Start Wiring
(BF) Factor (BEF) %
Temp Diag. Dim.
13.78”
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
WIRING DIAGRAMS
—
DIAGRAM 37
ESX
PAGE 2-44
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Energy Management System
DCL® with DEMANDflex®
DEMANDflex® ballasts are high efficiency program start
ballasts with the flexibility to be tuned at the circuit level
to fixed power levels during installation. They are fully
compatible with occupancy sensors and exceed the CEE
requirements for high efficiency program start T8
ballasts. DEMANDflex® ballasts having tuning capabilities with ranges from 100% to 50% power levels, making
them applicable for a wide range of lighting installations.
Installations can start with DEMANDflex® ballasts and
after installation, the ballasts can be tuned to maximize
energy savings with fixed light levels. No dimming
control wires are associated with DEMANDflex® ballasts
which makes them easy to install in all existing fluorescent lighting applications. DEMANDflex® ballasts can also
be integrated with DCL® controls to be part of the most
cost-effective lighting system available.
DCL® controls allow for local control with energy management systems and external control via the internet for
networked managed systems. DCL® controls allow for
integration with utility demand response programs that
provide for improved pricing contracts to end-users in
exchange for the utility to have the ability to lower
lighting power levels during periods of high demand.
DCL/DEMANDflex
Universal Lighting Technologies is a subsidiary of
Panasonic Electric Works Co., Ltd., a member of the Panasonic Group
Product Overview
DEMANDflex® Ballasts
n
Power level tuning potential to 50%
–Set the circuit power level at installation
–Typical 10% to 15% power reduction
n
Install the same as standard PRS ballasts
–No control wires necessary
–Standard mounting footprint
–Same wiring as program rapid start ballasts
n
High efficiency program start operation
–Exceeds CEE T8 requirements
–Compatible with occupancy sensors
n
NEMA premium
–Exceeds CEE T8 requirements
–Compatible with occupancy sensors
DCL® Controlled Systems
n
–Avoid high peak charges
–Reduce demand costs
n
Programmable fade rates
–Gradual transitions
–No disruptions
n
n
DCL/DEMANDflex
Reduces lighting power by up to 50%
Use existing power connections to communicate to the ballasts
–No control wires
Implement with various controls and systems
–BAS Systems
–Photo Cells
–Occupancy Sensors
–Contact Closure
For more information contact Universal or visit www.unvlt.com.
PAGE 3-2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
DEMANDflex®
FOR (1), (2), (3) & (4) LAMPS
DEMANDflex
niversal DCL® Dimming
U
Programmed Rapid Start
1, 2, 3, & 4 Lamp Applications
Visit www.unvlt.com for a comprehensive
description of the DCL® system and
DEMANDflex® ballasts
•
•
•
•
T8
Lamp
Certification Line Input Power Ballast Ballast
Min. F/C
Starting Line
Catalog Current Power Factor Factor Efficacy THD
Start
Qty. Method Volts
Number
c (Amps) (Watts) (PF)
(BF) Factor (BEF) %
Temp
F32T8 - One Lamp Applications
Wiring
Diag. Dim.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.24
0.11
0.11
0.05
0.32
0.15
0.14
0.07
0.20
0.09
0.09
0.05
29
14
29
14
38
18
39
19
24
11
24
12
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
0.88
0.28
0.88
0.28
1.15
0.50
1.15
0.50
0.68
0.18
0.68
0.18
3.01
2.05
3.03
1.96
3.03
2.78
2.95
2.63
2.85
1.64
2.85
1.57
< 10
< 15
< 10
< 15
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B232PUNVDR-A @ 100%
120
B232PUNVDR-A @ 50%
B232PUNVDR-A @ 100%
277
B232PUNVDR-A @ 50%
B232PUNVDRH-A @ 100%
120
2 PRS B232PUNVDRH-A @ 50%
B232PUNVDRH-A @ 100%
277
B232PUNVDRH-A @ 50%
B232PUNVDRL-A @ 100%
120
B232PUNVDRL-A @ 50%
B232PUNVDRL-A @ 100%
277
B232PUNVDRL-A @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.47
0.22
0.20
0.10
0.62
0.30
0.26
0.13
0.40
0.19
0.17
0.09
57
28
56
28
75
37
73
36
47
24
47
24
> .95
> .95
> .95
> .95
> .95
> .90
> .95
> .90
> .95
> .95
> .95
> .95
0.87
0.34
0.87
0.35
1.15
0.50
1.15
0.50
0.71
0.19
0.71
0.19
1.53
1.20
1.56
1.22
1.53
1.35
1.58
1.39
1.51
0.81
1.51
0.81
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B332PUNVDR-A @ 100%
120
B332PUNVDR-A @ 50%
B332PUNVDR-A @ 100%
277
B332PUNVDR-A @ 50%
B332PUNVDRL-A @ 100%
120
3 PRS B332PUNVDRL-A @ 50%
B332PUNVDRL-A @ 100%
277
B332PUNVDRL-A @ 50%
B332PUNVDRH-E @ 100%
120
B332PUNVDRH-E @ 50%
B332PUNVDRH-E @ 100%
277
B332PUNVDRH-E @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.70
0.34
0.30
0.16
0.59
0.29
0.25
0.13
0.95
0.48
0.41
0.21
85
42
83
41
72
36
72
36
115
57
111
55
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
0.87
0.35
0.87
0.35
0.71
0.22
0.71
0.22
1.15
0.50
1.15
0.50
1.02
0.83
1.05
0.85
0.99
0.61
0.99
0.61
1.00
0.88
1.04
0.91
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12c
12c
12c
12c
12c
12c
12c
12c
12d
12d
12d
12d
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B432PUNVDR-E @ 100%
120
B432PUNVDR-E @ 50%
B432PUNVDR-E @ 100%
277
4 PRS B432PUNVDR-E @ 50%
B432PUNVDRL-E @ 100%
120
B432PUNVDRL-E @ 50%
B432PUNVDRL-E @ 100%
277
B432PUNVDRL-E @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.96
0.48
0.41
0.20
0.78
0.37
0.34
0.17
116
58
112
56
93
47
93
47
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
0.88
0.35
0.88
0.35
0.71
0.21
0.71
0.21
0.75
0.60
0.79
0.63
0.76
0.45
0.76
0.45
< 10
< 10
< 10
< 15
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12e
12e
12e
12e
12e
12e
12e
12e
-A
-A
-A
-A
-A
-A
-A
-A
F32T8 - Two Lamp Applications
F32T8 - Three Lamp Applications
F32T8 - Four Lamp Applications
See page 3-7 for Dimensions and Wiring Diagrams
PAGE 3-3
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
DEMANDflex
B232PUNVDR-A @ 100%
120
B232PUNVDR-A @ 50%
B232PUNVDR-A @ 100%
277
B232PUNVDR-A @ 50%
B232PUNVDRH-A @ 100%
120
1 PRS B232PUNVDRH-A @ 50%
B232PUNVDRH-A @ 100%
277
B232PUNVDRH-A @ 50%
B232PUNVDRL-A @ 100%
120
B232PUNVDRL-A @ 50%
B232PUNVDRL-A @ 100%
277
B232PUNVDRL-A @ 50%
DEMANDflex
T8
•
•
•
•
DEMANDflex®
niversal DCL® Dimming
U
Programmed Rapid Start
1, 2, 3, & 4 Lamp Applications
Visit www.unvlt.com for a comprehensive
description of the DCL system and
DEMANDflex ballasts
FOR (1), (2), (3) & (4) LAMPS
Lamp
Certification Line Input Power Ballast Ballast
Min. F/C
Starting Line
Catalog Current Power Factor Factor Efficacy THD
Start
Qty. Method Volts
Number
c (Amps) (Watts) (PF)
(BF) Factor (BEF) %
Temp
F25T8 - One Lamp Applications
B232PUNVDR-A @ 100%
120
B232PUNVDR-A @ 50%
B232PUNVDR-A @ 100%
277
B232PUNVDR-A @ 50%
B232PUNVDRH-A @ 100%
120
1 PRS B232PUNVDRH-A @ 50%
B232PUNVDRH-A @ 100%
277
B232PUNVDRH-A @ 50%
B232PUNVDRL-A @ 100%
120
B232PUNVDRL-A @ 50%
B232PUNVDRL-A @ 100%
277
B232PUNVDRL-A @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.19
0.10
0.08
0.05
0.25
0.12
0.11
0.06
0.15
0.08
0.07
0.04
22
12
22
13
30
14
30
15
18
10
18
10
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .95
0.87
0.35
0.88
0.35
1.16
0.50
1.16
0.50
0.69
0.18
0.69
0.18
4.00
2.93
3.95
2.82
3.87
3.57
3.81
3.33
3.85
1.84
3.77
1.75
< 10
< 15
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B232PUNVDR-A @ 100%
120
B232PUNVDR-A @ 50%
B232PUNVDR-A @ 100%
277
B232PUNVDR-A @ 50%
B232PUNVDRH-A @ 100%
120
2 PRS B232PUNVDRH-A @ 50%
B232PUNVDRH-A @ 100%
277
B232PUNVDRH-A @ 50%
B232PUNVDRL-A @ 100%
120
B232PUNVDRL-A @ 50%
B232PUNVDRL-A @ 100%
277
B232PUNVDRL-A @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.36
0.19
0.16
0.09
0.46
0.21
0.20
0.10
0.30
0.15
0.13
0.07
44
23
43
23
55
26
55
26
36
18
35
18
> .95
> .95
> .95
> .95
> .95
> .90
> .95
> .90
> .95
> .95
> .95
> .95
0.87
0.35
0.87
0.35
1.15
0.50
1.15
0.50
0.69
0.19
0.69
0.19
2.01
1.56
2.05
1.53
2.09
1.92
2.08
1.92
1.93
1.06
1.95
1.03
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B332PUNVDR-A @ 100%
120
B332PUNVDR-A @ 50%
B332PUNVDR-A @ 100%
277
B332PUNVDR-A @ 50%
B332PUNVDRL-A @ 100%
120
3 PRS B332PUNVDRL-A @ 50%
B332PUNVDRL-A @ 100%
277
B332PUNVDRL-A @ 50%
B332PUNVDRH-E @ 100%
120
B332PUNVDRH-E @ 50%
B332PUNVDRH-E @ 100%
277
B332PUNVDRH-E @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.55
0.27
0.24
0.13
0.47
0.24
0.21
0.11
0.74
0.35
0.33
0.16
66
33
65
32
56
28
55
29
89
42
89
43
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .95
0.87
0.35
0.87
0.35
0.71
0.23
0.71
0.23
1.17
0.50
1.17
0.50
1.32
1.06
1.34
1.09
1.27
0.81
1.29
0.80
1.31
1.19
1.31
1.16
< 10
< 10
< 10
< 15
< 10
< 10
< 10
< 10
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12c
12c
12c
12c
12c
12c
12c
12c
12d
12d
12d
12d
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B432PUNVDR-E @ 100%
120
B432PUNVDR-E @ 50%
B432PUNVDR-E @ 100%
277
4 PRS B432PUNVDR-E @ 50%
B432PUNVDRL-E @ 100%
120
B432PUNVDRL-E @ 50%
B432PUNVDRL-E @ 100%
277
B432PUNVDRL-E @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.75
0.37
0.33
0.17
0.61
0.31
0.27
0.15
90
44
89
44
73
37
72
38
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .90
0.89
0.35
0.89
0.35
0.71
0.21
0.71
0.21
0.99
0.80
1.00
0.80
0.97
0.56
0.98
0.56
< 10
< 15
< 10
< 15
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12e
12e
12e
12e
12e
12e
12e
12e
-A
-A
-A
-A
-A
-A
-A
-A
F25T8 - Two Lamp Applications
F25T8 - Three Lamp Applications
F25T8 - Four Lamp Applications
DEMANDflex
Wiring
Diag. Dim.
See page 3-7 for Dimensions and Wiring Diagrams
PAGE 3-4
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
DEMANDflex®
•
•
•
•
FOR (1), (2), (3) & (4) LAMPS
DEMANDflex
niversal DCL® Dimming
U
Programmed Rapid Start
1, 2, 3, & 4 Lamp Applications
Visit www.unvlt.com for a comprehensive
description of the DCL system and
DEMANDflex ballasts
T8
Lamp
Certification Line Input Power Ballast Ballast
Min. F/C
Starting Line
Catalog Current Power Factor Factor Efficacy THD
Start
Qty. Method Volts
Number
c (Amps) (Watts) (PF)
(BF) Factor (BEF) %
Temp
F17T8 - One Lamp Applications
Wiring
Diag. Dim.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.14
0.08
0.06
0.04
0.18
0.09
0.09
0.05
0.11
0.09
0.05
0.04
16
10
17
10
22
11
22
11
13
10
13
11
> .95
> .95
> .95
> .85
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .85
0.92
0.27
0.92
0.27
1.15
0.50
1.15
0.50
0.70
0.20
0.70
0.20
5.65
2.81
5.48
2.66
5.23
4.63
5.23
4.55
5.47
1.98
5.22
1.87
< 10
< 15
< 10
< 15
< 10
< 15
< 10
< 15
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B232PUNVDR-A @ 100%
120
B232PUNVDR-A @ 50%
B232PUNVDR-A @ 100%
277
B232PUNVDR-A @ 50%
B232PUNVDRH-A @ 100%
120
2 PRS B232PUNVDRH-A @ 50%
B232PUNVDRH-A @ 100%
277
B232PUNVDRH-A @ 50%
B232PUNVDRL-A @ 100%
120
B232PUNVDRL-A @ 50%
B232PUNVDRL-A @ 100%
277
B232PUNVDRL-A @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.25
0.13
0.13
0.06
0.32
0.16
0.14
0.07
0.21
0.12
0.09
0.06
30
16
30
16
38
19
39
19
25
15
25
15
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .95
0.90
0.27
0.90
0.27
1.16
0.50
1.16
0.50
0.69
0.19
0.69
0.19
3.00
1.72
3.00
1.67
3.05
2.63
2.97
2.63
2.78
1.29
2.76
1.24
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 15
< 10
< 10
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B332PUNVDR-A @ 100%
120
B332PUNVDR-A @ 50%
B332PUNVDR-A @ 100%
277
B332PUNVDR-A @ 50%
B332PUNVDRL-A @ 100%
120
3 PRS B332PUNVDRL-A @ 50%
B332PUNVDRL-A @ 100%
277
B332PUNVDRL-A @ 50%
B332PUNVDRH-E @ 100%
120
B332PUNVDRH-E @ 50%
B332PUNVDRH-E @ 100%
277
B332PUNVDRH-E @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.40
0.20
0.18
0.10
0.33
0.18
0.15
0.09
0.54
0.25
0.24
0.12
48
24
48
24
40
22
40
23
65
32
65
32
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .85
> .95
> .95
> .95
> .90
0.89
0.36
0.89
0.36
0.73
0.23
0.73
0.23
1.19
0.51
1.19
0.51
1.86
1.51
1.86
1.51
1.83
1.05
1.83
1.02
1.83
1.59
1.84
1.59
< 10
< 10
< 10
< 15
< 10
< 10
< 10
< 15
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12c
12c
12c
12c
12c
12c
12c
12c
12d
12d
12d
12d
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B432PUNVDR-E @ 100%
120
B432PUNVDR-E @ 50%
B432PUNVDR-E @ 100%
277
4 PRS B432PUNVDR-E @ 50%
B432PUNVDRL-E @ 100%
120
B432PUNVDRL-E @ 50%
B432PUNVDRL-E @ 100%
277
B432PUNVDRL-E @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.53
0.27
0.24
0.13
0.43
0.26
0.20
0.12
64
32
63
32
52
31
52
31
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .90
0.91
0.35
0.91
0.35
0.73
0.21
0.73
0.21
1.42
1.09
1.44
1.09
1.41
0.69
1.41
0.67
< 10
< 15
< 10
< 15
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12e
12e
12e
12e
12e
12e
12e
12e
-A
-A
-A
-A
-A
-A
-A
-A
F17T8 - Two Lamp Applications
F17T8 - Three Lamp Applications
F17T8 - Four Lamp Applications
See page 3-7 for Dimensions and Wiring Diagrams
FOR MORE INFORMATION CALL
PAGE 3-5
1-800-BALLAST
(225-5278)
DEMANDflex
B232PUNVDR-A @ 100%
120
B232PUNVDR-A @ 50%
B232PUNVDR-A @ 100%
277
B232PUNVDR-A @ 50%
B232PUNVDRH-A @ 100%
120
1 PRS B232PUNVDRH-A @ 50%
B232PUNVDRH-A @ 100%
277
B232PUNVDRH-A @ 50%
B232PUNVDRL-A @ 100%
120
B232PUNVDRL-A @ 50%
B232PUNVDRL-A @ 100%
277
B232PUNVDRL-A @ 50%
DEMANDflex
•
•
•
•
•
T5, T5HO & TT5
niversal DCL® Dimming
U
Programmed Rapid Start
2 Lamp Applications for T5 & T5HO
1 & 2 Lamp Applications for TT5
Visit www.unvlt.com for a comprehensive
description of the DCL system and DEMANDflex ballasts
DEMANDflex®
FOR (2) T5, (2) T5HO and
FOR (1) & (2) TT5 LAMPS
Lamp
Certification Line Input Power Ballast Ballast
Min. F/C
Starting Line
Catalog Current Power Factor Factor Efficacy THD
Start
Qty. Method Volts
Number
c (Amps) (Watts) (PF)
(BF) Factor (BEF) %
Temp
F28T5 - Two Lamp Applications
B228PUNVDRH-D @ 100%
120
2 PRS B228PUNVDRH-D @ 50%
B228PUNVDRH-D @ 100%
277
B228PUNVDRH-D @ 50%
•
•
•
•
•
•
•
•
0.60
0.30
0.25
0.13
72
36
70
35
> .95
> .95
> .95
> .95
1.15
0.51
1.15
0.50
1.60
1.42
1.64
1.43
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
12f
12f
12f
12f
-A
-A
-A
-A
B228PUNVDRH-D @ 100%
120
2 PRS B228PUNVDRH-D @ 50%
B228PUNVDRH-D @ 100%
277
B228PUNVDRH-D @ 50%
•
•
•
•
•
•
•
•
0.75
0.38
0.31
0.17
90
45
87
44
> .95
> .95
> .95
> .95
1.13
0.51
1.13
0.51
1.26
1.13
1.30
1.16
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
12f
12f
12f
12f
-A
-A
-A
-A
B228PUNVDRH-D
120
2 PRS B228PUNVDRH-D
B228PUNVDRH-D
277
B228PUNVDRH-D
@ 100%
@ 50%
@ 100%
@ 50%
•
•
•
•
•
•
•
•
0.47
0.23
0.20
0.11
56
28
55
28
> .95
> .95
> .95
> .90
1.16
0.51
1.16
0.51
2.07
1.82
2.11
1.82
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
12f
12f
12f
12f
-A
-A
-A
-A
B228PUNVDRH-D
120
2 PRS B228PUNVDRH-D
B228PUNVDRH-D
277
B228PUNVDRH-D
@ 100%
@ 50%
@ 100%
@ 50%
•
•
•
•
•
•
•
•
0.34
0.16
0.15
0.08
40
19
40
20
> .95
> .95
> .95
> .85
1.17
0.52
1.17
0.52
2.93
2.74
2.93
2.60
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
12f
12f
12f
12f
-A
-A
-A
-A
B254PUNVDR-D @ 100%
120
2 PRS B254PUNVDR-D @ 50%
B254PUNVDR-D @ 100%
277
B254PUNVDR-D @ 50%
•
•
•
•
•
•
•
•
1.00
0.50
0.43
0.22
120
60
120
60
> .95
> .95
> .95
> .90
1.00
0.45
1.00
0.45
0.83
0.75
0.83
0.75
< 10
< 10
< 10
< 10
0/-18
0/-18
0/-18
0/-18
12f
12f
12f
12f
-A
-A
-A
-A
B254PUNVDR-D @ 100%
120
2 PRS B254PUNVDR-D @ 50%
B254PUNVDR-D @ 100%
277
B254PUNVDR-D @ 50%
•
•
•
•
•
•
•
•
0.90
0.41
0.39
0.19
108
50
106
50
> .95
> .95
> .95
> .95
1.06
0.57
1.06
0.57
0.98
1.14
1.00
1.14
< 10
< 10
< 10
< 10
0/-18
0/-18
0/-18
0/-18
12f
12f
12f
12f
-A
-A
-A
-A
B254PUNVDR-D
120
2 PRS B254PUNVDR-D
B254PUNVDR-D
277
B254PUNVDR-D
@ 100%
@ 50%
@ 100%
@ 50%
•
•
•
•
•
•
•
•
0.97
0.47
0.42
0.21
115
57
113
57
> .95
> .95
> .95
> .95
1.10
0.63
1.11
0.63
0.96
1.11
0.98
1.11
< 10
< 10
< 10
< 10
0/-18
0/-18
0/-18
0/-18
12f
12f
12f
12f
-A
-A
-A
-A
B254PUNVDR-D
120
2 PRS B254PUNVDR-D
B254PUNVDR-D
277
B254PUNVDR-D
@ 100%
@ 50%
@ 100%
@ 50%
•
•
•
•
•
•
•
•
0.88
0.41
0.38
0.19
106
49
104
48
> .95
> .95
> .95
> .95
1.04
0.56
1.04
0.56
0.98
1.14
1.00
1.17
< 10
< 10
< 10
< 10
0/-18
0/-18
0/-18
0/-18
12f
12f
12f
12f
-A
-A
-A
-A
C240PUNVDR-A
120
2 PRS C240PUNVDR-A
C240PUNVDR-A
277
C240PUNVDR-A
@ 100%
@ 50%
@ 100%
@ 50%
•
•
•
•
•
•
•
•
0.59
0.30
0.25
0.13
69
35
68
34
> .95
> .90
> .95
> .90
0.88
0.40
0.88
0.40
1.28
1.14
1.29
1.18
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
12g
12g
12g
12g
-A
-A
-A
-A
C240PUNVDR-A
120
1 PRS C240PUNVDR-A
C240PUNVDR-A
277
C240PUNVDR-A
@ 100%
@ 50%
@ 100%
@ 50%
•
•
•
•
•
•
•
•
0.29
0.16
0.13
0.08
34
18
36
20
> .95
> .90
> .95
> .90
0.88
0.40
0.88
0.40
2.59
2.22
2.44
2.00
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
12h
12h
12h
12h
-A
-A
-A
-A
120 C240PUNVDR-A @ 100%
277 C240PUNVDR-A @ 100%
•
•
•
•
0.52
0.22
62
62
> .95
> .95
0.86
0.87
1.39
1.40
< 10
< 10
32/0
32/0
12g
12g
-A
-A
120 C240PUNVDR-A @ 100%
277 C240PUNVDR-A @ 100%
•
•
•
•
0.25
0.12
28
33
> .95
> .95
0.87
0.87
3.11
2.64
< 10
< 10
32/0
32/0
12h
12h
-A
-A
F35T5 - Two Lamp Applications
F21T5 - Two Lamp Applications
F14T5 - Two Lamp Applications
F54T5HO - Two Lamp Applications
FT55W/2G11 - Two Lamp Applications
FT50W/2G11 - Two Lamp Applications
FC12T5-55W - Two Lamp Applications
FT40W/2G11 - Two Lamp Applications
DEMANDflex
Wiring
Diag. Dim.
FT40W/2G11 - One Lamp Applications
FT40W/2G11/ES - Two Lamp Applications
2 PRS
1 PRS
FT40W/2G11/ES - One Lamp Applications
See page 3-7 for Dimensions and Wiring Diagrams
PAGE 3-6
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
DEMANDflex
T8
DEMANDflex®
WIRING DIAGRAMS
Wiring Diagram 12a
Wiring Diagram 12e
Wiring Diagram 12b
Wiring Diagram 12f
Wiring Diagram 12c
Wiring Diagram 12g
Wiring Diagram 12d
Wiring Diagram 12h
DEMANDflex
FOR MORE INFORMATION CALL
PAGE 3-7
1-800-BALLAST
(225-5278)
DCL Controls
DCL CONTROLS
LP12DCLUNV-xx
MODEL
DESCription
LP12DCLUNV-xx
SC20DCLUNV
RSMDCL51
WTPDCL51
WPS5527K
Circuit Control Panel
Single Circuit Controller
Contact Interface Controller
Time/Photo Controller
Photo Sensor for WTPDCL
Dimensions
Length
32”
Width
20”
Depth
4.3”
Mounting
24”
16”
The same cabinet size is used
for the four different panels. the
quantity of individual controllers
installed is determined by the
model number.
xx = number of circuits (03-12)
SC20DCLUNV
Mounting pattern
Dimensions
Length
9.66”
Width
3.98”
Depth
3.21”
Circuit control panels are used to send commands down the lighting circuit to the DemandFlex ballasts. The
LP12DCLUNV-xx panels are available with 3 to 12 integral circuit control modules. If more than 12 circuits are
being controlled, additional panels can be used.
The SC20DCLUNV is used when there are a small number of circuits or space limitations prevent the use of
an LP12DCLUNV panel.
One RSMDCL51 or WTPDCL51 can control up to 63 circuits. If more than 63 circuits are to be controlled, an
RSMDCL can be connected in parallel with either controller for another 63 circuits.
Stand Alone Time Clock/Photo Cell
DCL Controls
Contact Closure Interface Control
The WTPDCL51 controller provides time of day
scheduling and can also be connected to the
WPS5527K Photo Cell for daylight harvesting.
Manual override switches are also available.
The RSMDCL51 controller integrates with external
relays or switches to translate commands to the DCL
system. This controller can be used to interface with
building automation systems, PLC’s, or switches.
These systems may also incorporate photo cells for
dayllight harvesting.
FOR MORE INFORMATION CALL
PAGE 3-8
1-800-BALLAST
(225-5278)
Controllable Lighting
Fluorescent Energy
Management / Dimming
Ballasts and Controls
The effective dimming of fluorescent lights delivers a wide
range of benefits: greater control of workspace lighting, ability
to create a mood, energy savings, and more.
Universal Lighting Technologies (“Universal”) line of electronic
dimming ballasts and controls lets you accomplish these goals
with a variety of products to suit your dimming needs. From
light level switching and analog dimming to digital dimming and
controls, Universal has the products and technologies to meet
today’s dimming requirements for energy savings and controllable lighting.
Fluorescent Dimming
Universal Lighting Technologies is a subsidiary of
Panasonic Electric Works Co., Ltd., a member of the Panasonic Group
Product Overview
Universal offers three different families of dimming products that can be used for today’s dimming
requirements for architectural lighting control and energy management applications:
Ballastar: Light Level Switching
SuperDim: Analog (0 to 10 volt) dimming
DaliPro: Digital Dimming with the DALI protocol
Ballastar® Light Level Switching (S30 & S50)
Our Ballastar® line offers two options of light level switching (either 100/50% or 100/60/30%).
That makes Ballastar® a cost-effective solution for both new construction and retrofits.
Universal Ballastar® ballasts are designed to ensure optimum lamp performance. Their Lamp Current
Crest Factors are well below the maximum 1.7 ANSI standard — and they start the lamps according
to ANSI recommendations at all dimming levels. Both of these important design parameters ensure
optimum lamp performance. In addition, Ballastar® ballasts actually increase cathode heating when
dimming to maintain the cathode’s proper temperature, which enhances lamp life and performance stability.
Fluorescent Dimming
• 1, 2, & 3 lamp models for 120 & 277 volt
• Switches to preset light levels, keeping all lamps illuminated
• Eliminates the dark spots associated with inboard/outboard configurations
• Connects with two line voltage power leads
— Wires the same as an inboard/outboard fixture
— No special controls required; uses two wall switches
• Meets all ASHRAE 90.1 and California Title 24 requirements for lighting control
• THD <10%
• Lower installed costs; less wiring and equipment required
Ballastar® Light Level Switching for ultimate control.
PAGE 3-10
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Product Overview
SuperDim® Analog Dimming Ballasts
Universal Lighting’s new SuperDim® analog dimming ballasts are the most cost-effective choice for
large scale dimming applications. SuperDim® ballasts are designed for T8 and T5 linear fluorescent
lamps and T4 4-pin quad and triple compact fluorescent lamps.
SuperDim® ballasts are compatible with a wide range of 0 – 10 volt controls and can be connected to
photocells for daylight harvesting. The resulting energy savings makes it easy to adhere to even the
strictest energy requirements, including California Title 24 and ASHRAE 90.1.
These versatile ballasts offer programmed rapid start technology for longer lamp life. They also
incorporate end-of-lamp-life shutdown circuits, low profile designs and < 10% THD at full bright.
Features and Benefits
• Ideal for T8 and T5 linear fluorescent lamps and T4 4-pin
quad and triple compact fluorescent lamps
• Compatible with most 0 – 10 volt manufactured controls
• Daylight harvesting options with photocells for maximum
energy savings
• Programmed rapid start technology maximizes lamp life
• Low profile design for fixture design flexibility
• End-of-lamp-life shutdown circuitry ensures safe operation
• < 10% THD at full bright
• Universal input voltage (120–277 volts) for installation flexibility
Fluorescent Dimming
PAGE 3-11
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent Dimming
Notes
PAGE 3-12
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Product Overview
DaliPro Digital Dimming Ballasts for DALI
New DaliPro™ ballasts from Universal Lighting let you take full advantage of the Digital Addressable
Lighting Interface (DALI) standard...and that means greater flexibility, greater savings.
The DALI Advantage
The DALI protocol uses a 2-wire control loop to communicate with up to 64 ballasts. Broadcast, group
and individual addressing is used to control light levels, recall scenes and poll ballast status.
Many DALI-compatible controls are now available from established manufacturers; and new varieties
are being developed daily.
DaliPro Features and Benefits
• Available for T8, T5, T5HO and compact fluorescent lamps
• Provides dimming down to 1% for linear lamps and 3% for compact fluorescent lamps
• Lets you adapt instantly to additions or changes in lighting design without ballast or fixture rewiring
• Offers status/performance data, including lamp status and system faults
• Low profile designs for easy installation in a wide variety of fixtures
• Universal input voltage (120– 277 volts)
—Installer-friendly; ensures you have the right ballast every time
—Reduces inventory costs and requirements
• End-of-Lamp Life Shutdown with auto reset circuitry for safe operation
• Programmed Rapid Start for long lamp life
Fluorescent Dimming
PAGE 3-13
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
Dimming ballasts follow the same guidelines as electronic ballasts in regard to the application and operating information.
In addition to the section for electronic ballasts, the following applies specifically to dimming electronic ballasts.
SAFETY
Analog dimming ballasts are controlled by using a low voltage 10-0vDC control circuit. Care should be taken to insure that
the line voltage (AC) wires are not connected to the low voltage DC wires. SuperDim® Electronic dimming ballasts have a
protection circuit that will sense if the ballast has been connected in this manner and not harm the ballast or the installer. If
connected in this mode, the lamps will dim to the 30% level.
New Lamp Installation
When new lamps are installed, they must operate at a full bright level for a minimum of 100 hours prior to dimming.
Failure to do this will effect lamp life and cause the lamps to not dim properly. Consult your lamp manufacturer for further
lamp information.
Light Level Switching Installation Note
The two power leads for the light level switching ballasts must be connected to the same power circuit. The leads should
connect to separate switches or relays for control of the light level switching operation. Connection of the input leads to
separate power circuits can damage the ballasts.
Note:
Do not connect any other ballast to the load side of the switches controlling the switched
dimming ballast.
Compatible Dimming Controls
For a listing of compatible controls for universal analog ballasts, please consult catalog page 3-7, or call 1-800-BALLAST
or check out the Dimming and Controls section of our home page at www.unvlt.com.
Fusing
Fluorescent Dimming
Class P ballasts do not require fusing. Fusing can be used when a single circuit has a large number of fixtures/ballasts.
For a comprehensive list of appropriate fuses, contact our Technical Engineering Services (TES) Department at 1-800-BALLAST.
Detailed Operating Instructions
For additional information on all of Universal’s dimming products, consult our website at www.unvlt.com. Application
notes, dimming brochures and online training is available
PAGE 3-14
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Controls For Analog Dimming Ballasts
Manual Controls: Wall Stations & Hand-Held Remotes
Manufacturer
Website
Architectural Lighting Management
www.almsys.com
Douglas Lighting Controls, Inc.
www.douglaslightingcontrols.com
Electronics Diversified, Inc.
www.edionline.com
Genlyte Controls
www.lolcontrols.com
HUNT Dimming
www.huntdimming.com
Lehigh Electric Products Co.
www.lehighdim.com
Leviton
www.leviton.com
Lutron
www.lutron.com/universal
NexLight
www.nexlight.com
PLC-Multipoint
www.plcmultipoint.com
Sensor Switch, Inc.
www.sensorswitch.com
The Watt Stopper, Inc.
www.wattstopper.com
Telephone
(888) 446-9137
(604) 873-2797
(800) 547-2690
(800) 526-2731
(970) 484-9048
(610) 395-3386
(800) 323-8902
(888) LUTRON1 - Sales
(800) 523-9466 - Technical Support
(218) 828-3700
(425) 353-7552
(800) 727-7483
(800) 879-8585
Manufacturer
Website
Electronics Diversified, Inc.
www.edionline.com
Lehigh Electric Products Co.
www.lehighdim.com
Leviton
www.leviton.com
Lutron
www.lutron.com/universal
Marlin Controls, Inc.
www.marlincontrols.com
NexLight
www.nexlight.com
Novitas
www.novitas.com
The Watt Stopper, Inc.
www.wattstopper.com
Telephone
(800) 547-2690
(610) 395-3386
(800) 323-8902
(888) LUTRON1 - Sales
(800) 523-9466 - Technical Support
(800) 788-5750
(218) 828-3700
(310) 218-5360
(800) 879-8585
Occupancy Sensors & Controls
Photodetectors & Daylight Controls
Manufacturer
Website
Douglas Lighting Controls, Inc.
www.douglaslightingcontrols.com
Electronics Diversified, Inc.
www.edionline.com
Hubbell Building Automation, Inc.
www.hubbell-automation.com
Lehigh Electric Products Co.
www.lehighdim.com
Leviton
www.leviton.com
Lutron
www.lutron.com/universal
Marlin Controls, Inc.
www.marlincontrols.com
NexLight
www.nexlight.com
Novitas
www.novitas.com
PLC-Multipoint
www.plcmultipoint.com
Sensor Switch, Inc.
www.sensorswitch.com
The Watt Stopper, Inc.
www.wattstopper.com
Telephone
(604) 873-2797
(800) 547-2690
(888) 698-3242
(610) 395-3386
(800) 323-8902
(888) LUTRON1 - Sales
(800) 523-9466 - Technical Support
(800) 788-5750
(218) 828-3700
(310) 218-5360
(425) 353-7552
(800) 727-7483
(800) 879-8585
Systems: Control Panels, Building Management Systems, etc.
Telephone
(888) 446-9137
(604) 873-2797
(800) 547-2690
(800) 526-2731
(970) 484-9048
(610) 395-3386
(800) 323-8902
(888) LUTRON1 - Sales
(800) 523-9466 - Technical Support
(800) 788-5750
(218) 828-3700
(425) 353-7552
(800) 227-5154
(800) 879-8585
Universal Lighting Technologies Analog Dimming Ballasts
The information listed above is provided by Universal Lighting Technologies to facilitate development of dimming systems. All information has been provided by the controls
manufacturers, and Universal Lighting Technologies makes no guarantee regarding its accuracy. The reader is advised to contact these, and other manufacturers of analog dimming
systems, to obtain application advice, to determine availability of the controls listed above, and to learn about other controls that may be offered.
Data is subject to change without notice.
PAGE 3-15
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent Dimming
Manufacturer
Website
Architectural Lighting Management
www.almsys.com
Douglas Lighting Controls, Inc.
www.douglaslightingcontrols.com
Electronics Diversified, Inc.
www.edionline.com
Genlyte Controls
www.lolcontrols.com
HUNT Dimming
www.huntdimming.com
Lehigh Electric Products Co.
www.lehighdim.com
Leviton
www.leviton.com
Lutron
www.lutron.com/universal
Marlin Controls, Inc.
www.marlincontrols.com
NexLight
www.nexlight.com
PLC-Multipoint
www.plcmultipoint.com
Touch-Plate Lighting Controls
www.touchplate.com
The Watt Stopper, Inc.
www.wattstopper.com
DaliPro® DIMMING BALLASTS
Fluorescent Dimming
DaliPro®
Lamp
Starting
Line
Catalog
Qty. Method
Volts
Number
F32T8
120
1 PRS
B132PUNVDV1l
277
120
2 PRS
B232PUNVDV1l
277
F14T5
120
1 PRS
B114PUNVDV1
277
120
2 PRS
B214PUNVDV1
277
F28T5
120
1 PRS
B128PUNVDV1
277
120
2 PRS
B228PUNVDV1
277
F54T5HO
120
1 PRS
B154PUNVDV1
277
120
2 PRS
B254PUNVDV1
277
CFQ18W/Gx24q
120
1 PRS
C118PUNVDV3w£
277
120
2 PRS
C218PUNVDV3wn
277
CFQ26W/Gx24q
120
1 PRS
C126PUNVDV3w´
277
120
2 PRS
C226PUNVDV3wp
277
CFTR32W/Gx24q
120
1 PRS
C132PUNVDV3w
277
120
2 PRS
C232PUNVDV3w
277
CFM42W/Gx24q
120
1 PRS
C142PUNVDV3w
277
120
2 PRS
C242PUNVDV3w
277
FT40W/2G11
120
1 PRS
C140PUNVDV3w
277
120
2 PRS
C240PUNVDV3w
277
Line
Current
(Amps)
0.31
0.13
0.61
0.26
l Minimum Dimming Temperature is 50°F / 10°C
£Also operates (1) CFTR18W/Gx24q
n Also operates (2) CFTR18W/Gx24q
´Also operates (1) CFTR26W/Gx24q
pAlso operates (2) CFTR26W/Gx24q
Power
Factor
(PF)
Ballast
Factor
(BF)
Ballast
Efficacy
THD
Factor (BEF)
%
37
> .98
1.00
36
73
> .98
1.00
70
2.70
2.78
1.37
1.43
18
> .98
1.00
18
> .98
Min. F/C
Start
Wiring
Temp
Diag.
Dim.
<10
0/-18
7
DP1
<10
0/-18
8
DP1
5.56
<10
50/10
7
DP1
1.00
2.86
<10
50/10
8
DP1
0.27
0.11
0.55
0.23
32
> .98
1.00
31
66
> .98
1.00
63
3.13
3.23
1.52
1.59
<10
50/10
7
DP1
<10
50/10
8
DP1
0.52
0.22
1.05
0.44
62
> .98
1.00
60
126
> .98
1.00
121
1.61
1.67
0.79
0.83
<10
50/10
7
DP1
<10
50/10
8
DP1
0.19
0.10
0.34
0.16
21
> .95
1.00
20
39
> .95
1.00
38
4.76
5.00
2.56
2.63
<10
0/-18
9
DP2
<10
0/-18
10
DP2
0.28
0.12
0.50
0.23
28
> .95
1.00
27
54
> .95
1.00
53
3.57
3.70
1.85
1.89
<10
0/-18
9
DP2
<10
0/-18
10
DP2
0.34
0.15
0.58
0.26
38
> .95
1.00
37
71
> .95
1.00
70
2.63
2.70
1.41
1.43
<10
0/-18
9
DP2
<10
0/-18
10
DP2
0.43
0.19
0.82
0.36
47
> .95
1.00
45
92
> .95
1.00
91
2.13
2.22
1.09
1.10
<10
0/-18
9
DP2
<10
0/-18
10
DP2
0.37
0.16
0.83
0.37
45
> .95
1.00
44
97
> .95
1.00
94
2.22
2.27
1.03
1.06
<10
0/-18
9
DP1
<10
0/-18
10
DP1
0.15
0.07
0.28
0.13
All models are cULus Listed
w Minimum Dimming Temperature is 32°F / 0°C
Input
Power
(Watts)
See page 3-20for Dimensions
and Wiring Diagrams
STARTING METHOD LEGEND
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
PAGE 3-16
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
SuperDim ® DIMMING BALLASTS
SuperDim ®
Please visit www.unvlt.com for the most up to date status
and recent changes to the SuperDim product family.
Lamp
Starting
Qty. Method
F17T8
1 PRS
1 PRS
2 PRS
2 PRS
Power
Factor
(PF)
120
ES5833B
ES-1-T8-17-UNV-B-DIM-10
•
•
277
120
ES5818K
ES-1-T8-17-UNV-K-DIM-10
•
•
277
120
ES5834B
ES-2-T8-17-UNV-B-DIM-10
•
•
277
120
ES5817K
ES-2-T8-17-UNV-K-DIM-10
•
•
277
0.17
20
0.08
21
0.17
20
0.08
21
0.29
35
0.13
0.29
35
0.13
> .99
0.87
> .95
> .99
0.87
> .95
> .99
0.87
> .98
> .99
0.87
> .98
4.35
4.20
4.35
4.20
2.51
2.47
2.51
2.47
120
ES5821B
ES-1-T8-32/25-UNV-B-DIM-10
•
•
277
120
ES5835K
ES-1-T8-32/25-UNV-K-DIM-10
•
•
277
120
ES5822B
ES-2-T8-32/25-UNV-B-DIM-10
•
•
277
120
ES5836K
ES-2-T8-32/25-UNV-K-DIM-10
•
•
277
0.21
26
0.10
0.21
26
0.10
0.41
48
0.18
0.41
48
0.18
> .99
0.87
> .90
> .99
0.87
> .90
> .99
0.87
> .95
> .99
0.87
> .95
3.41
3.36
3.40
3.31
1.80
1.82
1.80
1.82
120
ES5821B
ES-1-T8-32/25-UNV-B-DIM-10
•
•
277
120
ES5835K
ES-1-T8-32/25-UNV-K-DIM-10
•
•
277
120
ES5822B
ES-2-T8-32/25-UNV-B-DIM-10
•
•
277
120
ES5836K
ES-2-T8-32/25-UNV-K-DIM-10
•
•
277
0.29
34
0.13
0.27
33
0.13
34
0.56
65
0.23
64
0.56
65
0.23
64
> .99
0.87
> .95
> .99
0.87
> .95
> .99
0.87
> .98
> .99
0.87
> .95
2.60
2.57
2.63
2.60
1.33
1.37
1.33
1.37
120
ES5849K
ES-1-T5-14-UNV-K-DIM-10
•
•
277
120
ES5851K
ES-2-T5-14-UNV-K-DIM-10
•
•
277
0.16
20
0.07
0.28
34
0.13
> .99
1.00
> .98
> .99
1.00
> .95
120
ES5839K
ES-1-T5-21-UNV-K-DIM-10
•
•
277
120
ES5861K
ES-2-T5-21-UNV-K-DIM-10
•
•
277
0.23
28
0.16
0.40
48
0.17
> .99
> .98
> .99
> .98
120
ES5846K
ES-1-T5-28-UNV-K-DIM-10
•
•
277
120
ES5847K
ES-2-T5-28-UNV-K-DIM-10
•
•
277
F35T5
120
1 PRS
ES5853K
ES-1-T5-35-UNV-K-DIM-10
•
•
277
CFQ/H13W
120
2 PRS
ES5011GT/HT£v ES-2/1-CFQ-13-UNV-GT/HT-DIM-10 •
•
277
CFQ/H18W
120
2 PRS
ES5012GT/HT nv ES-2/1-CFQ-18-UNV-GT/HT-DIM-10 •
•
277
CFQ/H26W
120
2 PRS
ES5013GT/HT´v ES-2/1-CFQ-26-UNV-GT/HT-DIM-10 •
•
277
CFH42W
120
1 PRS
ES5010GT/HT pv ES-1-CFH-42/36/26-UNV-GT/HT-DIM-10
•
•
277
FT40W/2G11
120
1 PRS
ES5006BMµ
ES-1-CFT-40-UNV-BM-DIM-10
•
•
277
120
2 PRS
ES5007BMTµ
ES-2-CFT-40-UNV-BMT-DIM-10
•
•
277
£Also operates (1) CFQ/H13W
n Also operates (1) CFQ/H18W
´Also operates (1) CFQ/H26W
pAlso operates (1) CFH32W and (1) FQ/H26W
HT suffix—Lead entry is bottom feed
GT suffix—Lead entry is end feed
µIncorporates lead wires
v
PAGE 3-17
Ballast Ballast
Factor Efficacy THD
(BF) Factor (BEF) %
Min. F/C
Start Wiring
Temp Diag. Dim.
<10
32/0
1
ESB
<10
32/0
1
ESK
<10
32/0
2
ESB
<10
32/0
2
ESK
<10
32/0
1
ESB
<10
32/0
1
ESK
<10
32/0
1
ESB
<10
32/0
1
ESK
<10
32/0
1
ESB
<10
32/0
1
ESK
<10
32/0
2
ESB
<10
32/0
2
ESK
5.13
4.95
<10
32/0
1
ESK
2.94
<10
32/0
2
ESK
1.00
3.64
<10
32/0
1
ESK
1.00
2.08
<10
32/0
2
ESK
0.30
37
0.14
0.56
67
0.25
> .99
1.00
> .95
> .99
1.00
> .98
2.67
2.71
1.49
1.50
<10
32/0
1
ESK
<10
32/0
2
ESK
0.34
0.15
40
41
> .99
1.00
> .98
2.50
2.44
<10
32/0
1
ESK
0.25
0.11
30
29
> .99
1.00
> .95
3.38
3.41
<10
32/0
3
GT/HT
0.31
38
0.14
> .99
> .95
1.00
2.66
<10
32/0
3
GT/HT
0.46
0.19
54
52
> .99
1.00
> .95
1.85
1.94
<10
32/0
3
GT/HT
0.34
46
0.15
> .99
1.00
> .95
2.41
2.20
<10
32/0
4
GT/HT
44
> .99
1.09
43
> .98
88
> .99
1.09
87
2.48
2.53
1.24
1.25
<10
32/0
5
ESBM
<10
32/0
6
ESBMT
0.35
0.16
0.73
0.31
STARTING METHOD LEGEND
PRS = Programmed Rapid Start
See page 3-20 for Dimensions
and Wiring Diagrams
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent Dimming
F25T8
1 PRS
1 PRS
2 PRS
2 PRS
F32T8
1 PRS
1 PRS
2 PRS
2 PRS
F14T5
1 PRS
2 PRS
F21T5
1 PRS
2 PRS
F28T5
1 PRS
2 PRS
Certification Line
Input
Line
Catalog
Current Power
Volts
Number
Description
(Amps) (Watts)
BALLASTAR
0-10V
DIMMING
T8 Straight Lamps
• Rapid Start
• 1, 2, 3 & 4 Lamp Applications
FOR (1), (2), (3) & (4) T8 LAMPS
Please visit www.unvlt.com for the most up to date status
and recent changes to the Ballastar 0-10V product family.
T12 U-Shaped Lamps
Fluorescent Dimming
BALLASTAR ® 0-10 VOLT
DIMMING BALLASTS
• Analog Dimming
Lamp
Starting
Line
Catalog
Qty. Method Volts
Number
F25T8 - One Lamp Applications
B132R120V5 @ 100%
120
B132R120V5 @ 5%
B132R277V5 @ 100%
1
RS
277
B132R277V5 @ 5%
B132R347V5 @ 100%
347
B132R347V5 @ 5%
F25T8 - Two Lamp Applications
B232SR347V5 @ 100%
2
RS
347
B232SR347V5 @ 5%
F25T8 - Four Lamp Applications
B432P277V5-E @ 100%
4 PAR-PRS 277
B432P277V5-E @ 5%
F32T8 - One Lamp Applications
B132R120V5 @ 100%
120
B132R120V5 @ 5%
B132R277V5 @ 100%
1
RS
277
B132R277V5 @ 5%
B132R347V5 @ 100%
347
B132R347V5 @ 5%
F32T8 - Two Lamp Applications
B232SR120V5 @ 100%
120
B232SR120V5 @ 5%
B232SR277V5 @ 100%
2 SER-RS 277
B232SR277V5 @ 5%
B232SR347V5 @ 100%
347
B232SR347V5 @ 5%
B232SR347V5 @ 100%
2
RS
347
B232SR347V5 @ 5%
F32T8 - Three Lamp Applications
B332SR120V5 @ 100%
120
B332SR120V5 @ 5%
3 SER-RS
B332SR277V5 @ 100%
277
B332SR277V5 @ 5%
F32T8 - Four Lamp Applications
B432SR277V5 @ 100%
4 SER/PAR-RS 277
B432SR277V5 @ 5%
B432P277V5-E@ 100%
4 SER-PRS 277
B432P277V5-E@ 5%
B432P277V5H-E@ 100%
4 SER-PRS 277
B432P277V5H-E@ 5%
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
0.22
0.06
0.10
0.03
0.08
0.02
26
7
26
7
26
7
> .99
> .90
> .99
> .90
> .99
> .90
0.90
0.05
0.90
0.05
0.90
0.05
3.46
0.71
3.46
0.71
3.46
0.71
< 10
< 15
< 10
< 20
< 10
< 30
50/10
50/10
50/10
50/10
50/10
50/10
13
13
13
13
13
13
ST
ST
ST
ST
ST
ST
0.14
0.04
47
12
> .99
> .90
0.93
0.05
1.98
0.42
<10
<15
50/10
50/10
15
15
-E
-E
0.33
0.09
90
22
> .98
> .90
0.88
0.05
0.98
0.23
<10
<15
50/10
0/10
14
14
-E
-E
0.27
0.07
0.12
0.03
0.09
0.02
32
8
32
8
32
8
> .99
> .90
> .99
> .90
> .99
> .90
0.88
0.05
0.88
0.05
0.88
0.05
2.75
0.63
2.75
0.63
2.75
0.63
< 10
< 10
< 10
< 15
< 10
< 20
50/10
50/10
50/10
50/10
50/10
50/10
13
13
13
13
13
13
ST
ST
ST
ST
ST
ST
0.52
0.12
0.23
0.05
0.18
0.04
0.18
0.04
62
13
62
13
62
13
62
13
> .99
> .90
> .99
> .90
> .99
> .90
> .99
> .90
0.88
0.05
0.88
0.05
0.88
0.05
0.88
0.05
1.42
0.38
1.42
0.38
1.42
0.38
1.42
0.38
< 10
< 10
< 10
< 15
< 10
< 15
<10
<15
50/10
50/10
50/10
50/10
50/10
50/10
50/10
50/10
15
15
15
15
15
15
15
15
ST
ST
ST
ST
ST
ST
-E
-E
0.77
0.17
0.33
0.07
92
20
92
20
> .99
> .90
> .99
> .90
0.88
0.05
0.88
0.05
0.96
0.25
0.96
0.25
< 10
< 10
< 10
< 15
50/10
50/10
50/10
50/10
17
17
17
17
ST
ST
ST
ST
0.42
0.11
0.42
0.10
0.55
0.12
117
27
115
24
150
28
> .99
> .90
> .99
> .90
> .99
> .90
0.88
0.05
0.88
0.05
1.18
0.06
0.79
0.19
0.77
0.21
0.79
0.22
< 10
< 15
< 10
< 15
< 10
< 15
50/10
50/10
50/10
50/10
50/10
50/10
18
18
14
14
14
14
-ZZ
-ZZ
-E
-E
-E
-E
All models except B232SR347V5 are cULus Listed
B232SR347V5 is CSA Certified
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
See page 3-20 for Dimensions
and Wiring Diagrams
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAGE 3-18
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
BALLASTAR ® STEP DIMMING BALLASTS
BALLASTAR
LIGHT LEVEL
SWITCHING
• Step Dimming
• Rapid Start
FOR (1), (2) & (3) T8 LAMPS
T8 Straight Lamps
• 1-3 Lamp Applications
T12 U-Shaped Lamps
All models are cULus Listed
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
0.14
0.08
0.08
0.05
16
9
16
9
> .95
> .95
> .70
> .70
0.88
0.29
0.88
0.29
5.50
3.22
5.50
3.22
< 15
< 15
< 15
< 15
32/0
32/0
32/0
32/0
12a
12a
12a
12a
-A
-A
-A
-A
0.25
0.14
0.12
0.07
30
16
30
16
> .99
> .98
> .88
> .85
0.87
0.30
0.87
0.30
2.90
1.88
2.90
1.88
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
12
12
12
12
-A
-A
-A
-A
0.21
0.10
0.11
0.06
24
12
24
12
> .95
> .90
> .80
> .80
0.85
0.28
0.85
0.28
3.54
2.33
3.54
2.33
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
12a
12a
12a
12a
-A
-A
-A
-A
0.39
0.20
0.18
0.09
46
24
46
24
> .98
> .95
> .98
> .90
0.84
0.28
0.84
0.28
1.83
1.17
1.83
1.17
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
12
12
12
12
-A
-A
-A
-A
0.27
0.19
0.12
0.13
0.09
0.06
0.25
0.12
0.12
0.06
32
23
14
33
25
15
29
14
29
14
> .99
> .99
> .98
> .99
> .98
> .95
> .99
> .98
> .85
> .80
0.89
0.60
0.28
0.89
0.63
0.28
0.88
0.29
0.88
0.29
2.78
2.61
2.00
2.70
2.52
1.87
3.03
2.07
3.03
2.07
< 10
< 10
< 10
< 10
< 15
< 20
< 10
< 10
< 10
< 20
50/10
50/10
50/10
50/10
50/10
50/10
32/0
32/0
32/0
32/0
11
11
11
11
11
11
12a
12a
12a
12a
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
0.52
0.38
0.24
0.23
0.17
0.11
0.48
0.24
0.21
0.11
62
45
28
62
45
28
57
28
56
28
> .99
> .95
> .95
> .99
> .95
> .95
> .99
> .99
> .95
> .90
0.88
0.58
0.27
0.88
0.58
0.27
0.88
0.30
0.88
0.30
1.42
1.29
0.96
1.42
1.29
0.96
1.54
1.07
1.57
1.07
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
50/10
50/10
32/0
32/0
32/0
32/0
12
12
12
12
12
12
12
12
12
12
ST
ST
ST
ST
ST
ST
-A
-A
-A
-A
0.78
0.61
0.40
0.34
0.26
0.16
93
69
43
94
69
43
> .99
> .95
> .95
> .99
> .95
> .95
0.88
0.60
0.30
0.88
0.60
0.30
0.95
0.87
0.70
0.94
0.87
0.70
< 10
< 10
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
50/10
50/10
16
16
16
16
16
16
ST
ST
ST
ST
ST
ST
See page 3-20 for Dimensions and Wiring Diagrams
PAGE 3-19
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent Dimming
Lamp
Starting
Line
Catalog
Qty. Method Volts
Number
F17T8 - One Lamp Applications
B232PUS50-A @ 100%
120
B232PUS50-A @ 50%
1
PRS
B232PUS50-A @ 100%
277
B232PUS50-A @ 50%
F17T8 - Two Lamp Applications
B232PUS50-A @ 100%
120
B232PUS50-A @ 50%
2
PRS
B232PUS50-A @ 100%
277
B232PUS50-A @ 50%
F25T8 - One Lamp Applications
B232PUS50-A @ 100%
120
B232PUS50-A @ 50%
1
RS
B232PUS50-A @ 100%
277
B232PUS50-A @ 50%
F25T8 - Two Lamp Applications
B232PUS50-A @ 100%
120
B232PUS50-A @ 50%
2 SER-RS
B232PUS50-A @ 100%
277
B232PUS50-A @ 50%
F32T8 - One Lamp Applications
B132R120S30 @ 100%
120
B132R120S30 @ 60%
B132R120S30 @ 30%
B132R277S30 @ 100%
277
B132R277S30 @ 60%
1
RS
B132R277S30 @ 30%
B232PUS50-A @ 100%
120
B232PUS50-A @ 50%
B232PUS50-A @ 100%
277
B232PUS50-A @ 50%
F32T8 - Two Lamp Applicationswa
B232SR120S30 @ 100%
120
B232SR120S30 @ 60%
B232SR120S30 @ 30%
B232SR277S30 @ 100%
277
B232SR277S30 @ 60%
2 SER-RS
B232SR277S30 @ 30%
B232PUS50-A @ 100%
120
B232PUS50-A @ 50%
B232PUS50-A @ 100%
277
B232PUS50-A @ 50%
F32T8 - Three Lamp Applications
B332SR120S30 @ 100%
120
B332SR120S30 @ 60%
B332SR120S30 @ 30%
3 SER-RS
B332SR277S30 @ 100%
277
B332SR277S30 @ 60%
B332SR277S30 @ 30%
T8
DIMENSIONS AND WIRING DIAGRAMS
DIMMING
Overall Dimensions
Draw #
L
ST
-E
-ZZ
ESB
ESK
GT/HT
ESBM
ESBMT
DP1
DP2
9.50”
16.88”
16.40”
9.50”
16.65”
4.95”
9.50”
9.50”
18.00”
4.95”
W
2.40”
1.74”
2.40”
2.38”
1.24”
3.00”
2.38”
2.38”
1.18”
2.93”
Mounting Dimensions
H
M
X
1.55”
1.18”
1.50”
1.00”
1.00”
1.18”
1.00”
1.20”
1.18”
1.38”
8.89”
16.28”
15.88”
8.88”
16.30”
4.63”
8.88”
8.88”
17.70”
4.57”
1.69”
—
1.69”
—
—
—
—
—
—
—
DIAGRAM 6
DIAGRAM 13
DIAGRAM 7
-E, ESB, ESK, ESBM,
ESBMT, DP1
ST, -ZZ
Fluorescent Dimming
DIAGRAM 8
DIAGRAM 14
DIAGRAM 9
HT, DP2
GT
DIAGRAM 15
WIRING DIAGRAMS
DIAGRAM 10
DIAGRAM 1
DIAGRAM 16
DIAGRAM 11
DIAGRAM 2
DIAGRAM 3
DIAGRAM 12
DIAGRAM 17
DIAGRAM 4
DIAGRAM 12a
DIAGRAM 18
INDIVIDUALLY CAP YELLOW LEADS
DIAGRAM 5
PAGE 3-20
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
BALLASTAR ® STEP DIMMING BALLASTS
FOR T5 LAMPS
-D
-A
16.88”
9.50”
1.18”
1.70”
0.17
0.09
0.09
0.05
21
10
21
10
> .95
> .95
> .75
> .75
1.19
0.40
1.19
0.40
5.90
3.74
5.80
3.50
< 15
< 15
< 15
< 15
50/10
50/10
50/10
50/10
12a
12a
12a
12a
-A
-A
-A
-A
0.33
0.15
0.15
0.08
0.29
0.13
0.13
0.06
37.5
18
37
19
35
16
35
16
> .95
> .95
> .90
> .85
> .95
> .95
> .95
> .90
1.15
0.40
1.15
0.40
1.00
0.37
1.00
0.37
3.10
2.19
3.11
2.14
2.86
2.30
2.86
2.29
< 10
< 15
< 10
< 15
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
50/10
50/10
50/10
50/10
12
12
12
12
19
19
19
19
-A
-A
-A
-A
-D
-D
-D
-D
0.24
0.12
0.12
0.62
0.40
0.18
0.17
0.08
29
14
29
14
48
21
47
22
> .95
> .95
> .85
> .85
> .95
> .95
> .95
> .95
1.18
0.39
1.18
0.40
0.99
0.36
0.99
0.36
4.09
2.84
4.06
2.75
2.06
1.73
2.10
1.65
< 10
< 15
< 15
< 15
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
50/10
50/10
50/10
50/10
12a
12a
12a
12a
19
19
19
19
-A
-A
-A
-A
-D
-D
-D
-D
0.50
0.23
0.21
0.10
0.59
0.29
0.25
0.12
58
28
57
28
71
34
69
34
> .99
> .99
> .98
> .95
> .99
> .99
> .98
> .95
0.95
0.35
0.95
0.35
1.15
0.45
1.15
0.45
1.64
1.25
1.67
1.25
1.62
1.32
1.67
1.32
< 10
< 20
< 10
< 20
< 10
< 10
< 10
< 15
50/10
19
-D
50/10
19
-D
50/10
19
-D
50/10
19
-D
Mounting Dimensions
H
M
X
1.00”
1.18”
16.20”
8.89”
-D
—
—
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
-A
WIRING DIAGRAMS
PAGE 3-21
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent Dimming
W
T5 Straight Lamps
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF) (BF) Factor (BEF) %
Temp Diag. Dim.
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
Overall Dimensions
Draw #
L
• Programmed Rapid Start
• 2 Lamp Applications
Lamp
Starting
Line
Catalog
Qty. Method Volts
Number
F14T5 - One Lamp Applications
B214PU115S50A @ 100%
120
1
PRS
B214PU115S50A @ 50%
B214PU115S50A @ 100%
277
B214PU115S50A @ 50%
F14T5 - Two Lamp Applications
B214PU115S50A @ 100%
120
B214PU115S50A @ 50%
B214PU115S50A @ 100%
277
2
PRS
B214PU115S50A @ 50%
B228PU95S50D @ 100%
120
B228PU95S50D @ 50%
B228PU95S50D @ 100%
277
B228PU95S50D @ 50%
F21T5 - One Lamp Applications
B214PU115S50A @ 100%
120
1
PRS
B214PU115S50A @ 50%
B214PU115S50A @ 100%
277
B214PU115S50A @ 50%
B228PU95S50D @ 100%
120
2
PRS
B228PU95S50D @ 50%
B228PU95S50D @ 100%
277
B228PU95S50D @ 50%
F28T5 - Two Lamp Applications
B228PU95S50D @100%
120
B228PU95S50D @50%
2
PRS
B228PU95S50D @100%
277
B228PU95S50D @50%
B228PU115S50D @100%
120
B228PU115S50D @50%
2
PRS
B228PU115S50D @100%
277
B228PU115S50D @50%
º Preliminary Data
All models are cULus Listed
BALLASTAR
LIGHT LEVEL
SWITCHING
• Step Dimming
Fluorescent Dimming
Notes
PAGE 3-22
Compact Fluorescent
Ballasts
The Courage To Dream Small
Universal Lighting Technologies (“Universal”) offers a
full range of magnetic and electronic compact fluorescent ballasts. Our magnetic models come in a variety
of shapes and sizes, from core and coils to High Power
Factor potted ballasts with bottom exit leads and mounting studs for all downlighting applications.
Our newest electronic models offer installer-friendly
universal input voltage, which reduces your inventory
and ensures that you have the right voltage ballast every
time. These models feature a low profile case that fits in
any fixture. And their metal housing construction meets
all plenum codes and delivers maximum heat transfer to
extend ballast life.
Compact Fluorescent
Our newest compact fluorescent models offer installer-friendly universal
input voltage.
Universal Lighting Technologies is a subsidiary of
Panasonic Electric Works Co., Ltd., a member of the Panasonic Group
Product Overview
Electronic Compact Fluorescent Ballasts
Universal’s newest TRIAD® electronic compact fluorescent ballasts feature installer-friendly universal input
voltage (108 to 305 volts) and metal case designs for compliance with all plenum and construction code
requirements. They also offer an end-of-lamp-life shutdown circuit with auto-reset that meets ANSI/NEMA
requirements—a feature that eliminates lamp/socket damage while allowing you to replace failed lamps
after shutdown without turning off the power.
Our universal voltage compact fluorescent ballasts offer both 1- and 2-lamp operation—and they’re ideal for
a wide variety of downlight and surface mount applications for atriums, hotel corridors, offices, and outdoors.
All models operate multiple lamp types for added versatility in many different applications.
All universal voltage compact fluorescent ballasts incorporate Universal’s Programmed Rapid Start (PRS)
technology that increases lamp life for those frequently switched applications where occupancy sensors are
used. PRS is recommended by all lamp manufacturers.
For the Canadian market, we have 347 volt compact fluorescent models. These also offer outstanding reliability and lamp performance. These 347 volt models are available for 1 and 2 lamp operation for lamps
ranging from 13 to 70 Watts.
These ballasts are designed and manufactured for long life. Lamps can be mounted in close proximity to
these ballasts because they have no temperature-critical components near the can sides. And their circuit
board potting enhances reliability by lowering case temperatures.
CFL Mult-E Kit
The multi-exit ballast lead wire connectors accomodate side and bottom lead exit requirements.
The snap mount adapter plate adds bottom-exit studs and additional flexibility for replacement of
older magnetic ballasts. They also fit virtually every j-box cover and fixture application. This
product is for distribution sale only.
Compact Fluorescent
Mult-E Kit products:
C213UNVME000K
C218UNVME000K
C2642UNVME000K
Mult-E Kit contains:
Multi-exit ballast
Snap-mount adapter plate
Lead wire set
Wire extraction tool
Instructions
Magnetic Compact Fluorescent Ballasts
Universal offers a complete line of magnetic compact fluorescent ballasts, ranging from 5 - 40
watts (10 - 38 watts for 2D lamps). Both core & coil and F-can models are available...in a variety
of configurations that include Side Exit, Bottom Exit and Bottom Exit Studs.
FOR MORE INFORMATION CALL
PAGE 4-2
1-800-BALLAST
(225-5278)
Understanding Compact Fluorescent Technology
Compact fluorescent (CFL) lamps are single-ended and
plug into sockets. They’re sometimes referred to as “single-based” or “single-ended” fluorescent lamps.
Lamp Shapes
Today’s CFL lamps come in these basic shapes: twin tube,
quad, triple, multi and circular. Each of these shapes has its
own subset of sizes. For example, the twin tube may range
from 4˝ long (5 watt) to 22˝ long (40 watt).
OR
OR
Long Twin T5, 4-Pin
5w – 80w
Twin, 2-Pin
5w – 13w
In this catalog, Universal CFL ballasts are classified
according to lamp type. Icons representing each lamp
type provide a quick visual reference. Within each classification, the lamps and their appropriate ballasts can
be found by referring to the generic NEMA lamp descriptions.
Lamp Designation
There are two different industry-recognized
nomenclatures for identifying CFL lamps: ANSI
Lamp Designations and NEMA Lamp Designations. Here
are examples of each:
OR
2-Pin
4-Pin
Quad 9w – 27w
Lamp Bases
There are a variety of lamp bases used with today’s CFL
lamps. This provides a safeguard to make sure that the
proper lamp/ballast combination is installed. The lamp
base style is part of the ANSI/NEMA
designation.
Square (2D)
10w – 55w
ANSI Designation
13W / 7T4 / T / GX23 / PH
Lamp
Wattage
Multiple, 4-Pin
(GE & OSI)
18w – 70w
Multiple, 4-Pin
(Philips)
18w – 42w
Twin (T)
Quad (Q)
Multi (M)
2D (S)
Lamp
Diameter
1/8˝
Base
Starting:
PH – Preheat
RS – Rapid Start
NEMA Designation
T5 Circular
22w - 55w
CFT 13W / GX23
Pins and Starters
CFL lamps feature either two pins or four pins. Those
with two pins have starters built into their bases, and
they require a magnetic preheat ballast. The two-pin CFL
lamps are available in wattages from 5 to 28.
Twin (T)
Quad (Q)
Multi (M)
2D (S)
Watts
5, 7, 9, 13
9, 13, 18, 20, 26, 27
13, 18, 26, 32, 42
42, 57, 70
18, 24/27, 36/39, 40, 50, 80
10, 16, 21, 28, 38, 55
22, 40, 55
Lamp
Wattage
Base
Both lamp designations refer to lamp wattage, shape,
and base type. Since the NEMA designation is shorter, it
will probably be the nomenclature of choice in the future.
All of the major lamp companies have trade names for
various CFL lamp types, such as GE’s “Biax” and “2D”
lamps, OSI’s “Dulux,” and Philips’ “PL”. These names
have become more widely used than either of the industry designations.
GE
Low Watt Biax
Double Biax
Biax T/E
Biax Q/E
High Lumen Biax
2D
—
OSI
Philips
Dulux S, S/E
PL-S
Dulux D, D/E
PL-C
Dulux T, T/E, T/E/IN
PL-T
Dulux T/E/IN
PL-T
Dulux L, F
PL-L
––
––
Pentron
Silhouette
FOR MORE INFORMATION CALL
PAGE 4-3
1-800-BALLAST
(225-5278)
Compact Fluorescent
Four-pin lamps are traditionally powered by electronic
ballasts. These lamps do not have an internal starter, so
the other filament terminals (pins) are made
accessible for external connection to the ballasts. Note:
Universal offers both magnetic and electronic ballasts for
the four-pin 32 and 26 watt lamps and all four-pin Long
Twin T5 lamps.
Industry
Single or Twin
Double or Quad
Multiple
Multiple
Long Twin T5
Square
Circline
Lamp
Length
Configurations
Bottom Exit*
Bottom Exit with Studs**
Standard Side Exit–Both Ends
Electronic Side Exit
Electronic Bottom Exit
Electronic Bottom Exit with Studs
Electronic Multi-Exit
Compact Fluorescent
Standard Side Exit
For full versatility in application according to various fixture requirements, Universal manufactures encased ballasts in three lead and mounting
options. This catalog lists ordering codes for standard side exit units. *Bottom exit units should be ordered with suffix “-BE” attached to the
catalog number. **Bottom exit with studs should be ordered with suffix “-BES” attached to the catalog number.
(Example: Standard Unit: “4000P”; Bottom Exit unit “4000-BE”; Bottom Exit with Studs: “4000-BES”).
FOR MORE INFORMATION CALL
PAGE 4-4
1-800-BALLAST
(225-5278)
Product Overview
ANSI Lamp
Designation
NEMA Lamp
Designation
Built-In
Starter
GE
5W/4T4/T/G23/PH
7W/5T4/T/G23/PH
9W/6T4/T/G23/PH
13W/7T4/T/GX23/PH
CFT5W/G23
CFT7W/G23
CFT9W/G23
CFT13W/GX23
YES
YES
YES
YES
F5 BX
F7 BX
F9 BX
F13 BX
CF 5DS
CF 7DS
CF 9DS
CF 13DS
PL-S 5W
PL-S 7W
PL-S 9W
PL-S 13W
9W/4T4/Q/G23-2/PH
13W/5T4/Q/GX23-2/PH
CFQ9W/G23
CFQ13W/GX23
YES
YES
F9 DBX23
F13 DBX23
CF 9DD
CF 13DD
—
PL-C 13W/USA
13W/6T4/Q/G24d-1/PH
18W/7T4/Q/G24d-2/PH
26W/8T4/Q/G24d-3/PH
CFQ13W/G24d
CFQ18W/G24d
CFQ26W/G24d
YES
YES
YES
F13 DBX T4
F18 DBX T4
F26 DBX T4
—
CF 18DD
CF 26DD
PL-C 13W
PL-C 18W
PL-C 26W
CFQ13W/G24q
CFQ18W/G24q
CFQ26W/G24q
NO
NO
NO
F13 DBX/4P
F18 DBX/4P
F26 DBX/4P
CF 13DD/E
CF 18DD/E
CF 26DD/E
PL-C 13W/4P
PL-C 18W/4P
PL-C 26W/4P
10W/3.5T4/S/GR10q-4
16W/5.5T4/S/GR10q-4
21W/5.5T4/S/GR10q-4
28W/8T6/S/GR8-2/PH
28W/8T6/S/GR10q-4
38W/8T6/S/GR10q-4
55W/8T6/S/GRY10q-3
CFS10W/GR10q
CFS16W/GR10q
CFS21W/GR10q
CFS28W/GR8
CFS28W/GR10q
CFS38W/GR10q
CFS55W/GRY10q
NO
NO
NO
YES
NO
NO
NO
F10 2D/4P
F16 2D/4P
F21 2D/4P
F28 2D
F28 2D/4P
F38 2D/4P
F55 2D/4P
—
—
—
—
—
—
—
—
—
—
—
—
—
—
20W/6T5/Q/GX32d-2/PH
27W/7T5/Q/GX32d-3/PH
CFQ20W/GX32d
CFQ27W/GX32d
YES
YES
—
—
—
—
PL-C 15MM/22W
PL-C 15MM/28W
CFT13W/2GX7
NO
—
CF 13DS/E
—
18-20W/9T5/T/2G11/PH-RS
18W/10T5/T/2G11/RS
18W/5T5/T/2G10
24-27W/13T5/T/2G11/PH-RS
24W/7T5/T/2G10
36-39W/16T5/T/2G11/PH-RS
36W/9T5/T/2G10
40W/22T5/T/2G11/RS
50W/22T5/T/2G11/RS
55W/21T5/T/2G11
80W/22T5/T/2G11
FT18W/2G11
FT18W/2G11/RS
CFM18W/2G10
FT24W/2G11/RS
CFM24W/2G10
FT36W/2G11/RS
CFM36W/2G10
FT40W/2G11/RS
FT50W/2G11/RS
FT55W/2G11
FT80W/2G11
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
F18 BX
F18 BX/RS
—
F27 BX/RS
—
F39 BX/RS
—
F40 BX/RS
F50 BX/RS
F55 BX
—
FT 18DL
FT 18DL/RS
CF 18DF
FT 24DL
CF 24DF
FT 36DL
CF 36DF
FT 40DL/RS
—
FT 55DL
—
—
PL-L 18W
—
PL-L 24W
—
PL-L 36W
—
PL-L 40W/RS
PL-L 50W/RS
—
PL-L 80W
18W/5T4/M/GX24d-2
26W/6T4/M/GX24d-3
CFM18W/GX24d
CFM26W/GX24d
YES
YES
—
—
CF 18DT
CF 26DT
—
—
13W/5T4/M/GX24q-1
18W/5T4/M/GX24q-2
26W/6T4/M/GX24q-3
32W/6T4/M/GX24q-3
42W/7T4/M/GX24q-4
57W/7T4/M/GX24q-5
70W/8T4/M/GX24q-6
CFM13W/GX24q
CFM18W/GX24q
CFM26W/GX24q
CFM32W/GX24q
CFM42W/GX24q
CFM57W/GX24q
CFM70W/GX24q
NO
NO
NO
NO
NO
NO
NO
F13 TBX/4P
F18 TBX/4P
F26 TBX/4P
F32 TBX/4P/EOL
F42 TBX/4P/EOL
F57 QBX/4P/EOL
F70 QBX/4P/EOL
CF 13DT/E
CF 18DT/E/IN
CF 26DT/E/IN
CF 32DT/E/IN
CF 42DT/E/IN
CF 57DT/E/IN
—
—
PL-T 18W/4P
PL-T 26W/4P
PL-T 32W/4P
PL-T 42W/4P
—
—
—
—
—
FC9T5-22W/2GX13
FC12T5-40W/2GX13
FC12T5-55W/2GX13
NO
NO
NO
—
—
—
FPC22
FPC40
FPC55/HO
FC9T5 22W
FC12T5 40W
FC12T5 55W
LAMP MANUFACTURER
OSI
Philips
Twin, 2-Pin
Quad, 2-Pin
Quad, 2-Pin
OR
13W/6T4/Q/G24q-1
18W/7T4/Q/G24q-2
26W/8T4/Q/G24q-3
Quad, 4-Pin
Square, (2D)
T5 Quad, 2-Pin
13W/6T4/T/2GX7
Twin T4, 4-Pin
Long Twin T5, 4-Pin
Multiple, 4-Pin
T5 Circular, 4-Pin
FOR MORE INFORMATION CALL
PAGE 4-5
1-800-BALLAST
(225-5278)
Compact Fluorescent
Multiple, 2-Pin
Specifications
Compact Fluorescent
TYPICAL SPECIFICATIONS FOR
ELECTRONIC COMPACT FLUORESCENT BALLASTS
1.
2.
3.
4.
4a.
5.
6.
7.
8.
9.
10.
11.
12.
Ballast shall be Programmed Rapid Start.
Ballast shall incorporate lamp shutdown circuitry for end of lamp life protection.
Ballast shall allow for re-lamping without the need to cycle power.
Ballasts shall operate from 50/60 Hz input source of 120, 277, or 347 Volts with no damage
to the ballasts.
Ballasts shall operate from 50/60 Hz input source of 108-305 Volts with no damage to the
ballasts for High Performance (HP) models.
Ballast shall be of metal can construction to meet all plenum requirements and to eliminate the
need for extra grounding wires.
Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above
50 kHz to minimize interference with infrared control systems.
Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with
lamp manufacturer recommendation and ANSI C82.11-1993.
Ballasts shall tolerate operation in ambient temperatures up to 140°F (55°C) without damage.
Ballasts shall have a maximum case temperature test point of 75°C printed on the label for easy
fixture testing and trouble shooting.
Ballast shall have a maximum case temperature rise of 15°C.
Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line
conducted) and RFI (Radiated).
Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991.
13.
14.
15.
16.
17.
18.
Ballasts shall operate lamps with no visible flicker (<3% flicker index).
Ballasts shall tolerate sustained open and short circuit output conditions without damage.
Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA
certified, and unless noted otherwise, approved for use in hazardous locations (Type HL).
Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp.
Ballasts shall have a Power Factor greater than .98 for the primary lamp.
The ballasts shall not have any PCB’s.
19.
20.
21.
The manufacturer shall provide written warranty against defects in material or workmanship,
including replacement, for five years from date of manufacture.
Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years.
Ballast shall be manufactured in an ISO 9001 Certified Facility.
22. Universal model ___________ (or approved equal).
FOR MORE INFORMATION CALL
PAGE 4-6
1-800-BALLAST
(225-5278)
Understanding Universal Part Numbers
MAGNETIC
ELECTRONIC
Our part number nomenclature for magnetic ballasts is
shown below:
Our nomenclature for electronic CFL ballasts follows the
system already in place for other Universal electronic ballasts. The exceptions are that the model number
prefix for compact fluorescent is a C rather than a
B—and the suffixes for the mounting configuration
will be the same as those used for magnetic products (BE
and BES). If you don’t see these suffixes, the ballast has
traditional side exit leads.
Odd = NPF
Even = HPF
Thermally
Protected
Color:
001 – White
000 – Black
4XXX XX P XXX XXX X
1 – 120V
2 – 277V
3 – 347V
F1 – Frame
F2 – Fr. w/feet
H2 – Cover/Fr.
No suffix – Side Exit
BE – Bottom Exit
BES – Bottom Exit
with Studs
Lamp
Wattage
C – Carton
T – Tray Pack
UNV or 347V
Color: 001-White
000-Black
CXXX XX XXX XXX XXX X
Example: 4123PBES000T
Ballast for CFL Lamps: Indicated by “4” prefix
Voltage: 120V
Lamp Type: 26W Quad Lamp (refer to catalog
for wattage)
Power Factor: Normal
Encased and Potted: Indicated by absence of F1, F2,
or H2)
P: Thermally protected
BES: Bottom exit leads with studs
000: Color—Black
T: Packaging container style—Tray Pack
# of lamps
These ballasts are available for a wide variety of applications
with lamps, voltages, mounting configurations, and
performance characteristics. For more detailed information,
just identify the lamps to be ballasted and work forward to
determine the ballast part number.
SR-Series,
Rapid Start
R-Rapid Start
No suffix or SE –
C-Carton
Side Exit
T-Tray Pack
BE – Bottom Exit
I-Individual
BES – Bottom Exit
K-Replacement Kit
with Studs
ME-Multi Exit
MES-Multi Exit with Studs
Example:Electronic C240PUNVHP-B
Ballast Type: C — CFL Electronic Ballast
Lamp Qty: 2
Lamp Type: 40W TT5, 4 Pin (FT40W/2611)
P: Programmed Rapid Start
Voltage: UNV 120 to 277 volts
HP-B: High Performance <10%; low profile can
000: Color—Black
C: Packaging container style—Carton Pack
Lamp
Wattage*
120V, 277V
347V, UNV
(120-277)
Colors
000 – Black
001 – White
CXXX X XXX XXX XXX
# of Lamps
No suffix=P
P=Programmed
Rapid Start
I=Instant Start
X
T = Tray Pack
SE – Side Exit
C – Carton Pack
BE – Bottom Exit
I – Individual
BES – Bottom
K-Replacement Kit
Exit/Studs
ME– Multi Exit
MES– Multi Exit with Studs
HP-B – Low Profile
RH – Reduced Harmonics
*Exception is C2642, which does not distinguish
number of lamps. See catalog.
FOR MORE INFORMATION CALL
PAGE 4-7
1-800-BALLAST
(225-5278)
Compact Fluorescent
Example: C213UNVBES000C*
Ballast Type: C
Lamp Quantity: 2
Lamp Type: 13W Quad, 4 Pin (CFQ13W/G24q)
Voltage: UNV 120 to 277 volts
BES: Bottom exit connection, studs
000C: Color—Black
C: Packaging container style—Carton Pack
TWIN
LAMPS
• Open core & coil or encased
& potted designs
OR
MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT BALLASTS
• 1 & 2 lamp models available
5, 7, 9 & 11
WATTS
• Ideal for surface mount fixtures,
exit & retail display signs
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
7 Watts
CFT7W/G23
Mag Qty
Line
or
of Line Catalog Input Current
Elec Lamps Volt Number Watts Amps
Electrical Characteristics - 60 Hz
❍ M
1 120 4105F2P ■★ 10 0.18
M
1 120
4105P
10 0.18
FOR TWIN LAMPS
5, 7, 9 AND 11 WATTS
Lead Configuration
Starting
Min
Current Ballast Start Power Side Bottom Bottom Starting Wir
Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag
0.20
0.20
0.95 0° F Normal <10% X
0.95 0° F Normal <10% X
—
—
—
—
PH
PH
B2 1
C1 1
0.20
0.20
0.90 25° F Normal <10% X
0.90 25° F Normal <10% X
—
—
—
—
PH
PH
B2 1
C1 1
Twin, 2-Pin
Lamp Type
9 Watts
CFT9W/G23
OR
CFQ9W/G23
❍ M
M
1
1
120 4105F2P ■★ 10
120
4105P
10
0.18
0.18
OR
Twin or Quad,
2-Pin
★ Non-thermally protected models available.
✿ PH = Preheat
F2 indicates an open core & coil unit with mounting feet.
■ H2 indicates clamped & covered core & coil with mounting feet.
µ Add “B” for Bottom Exit or “S” for Side Exit or “BS” for
Bottom Exit with 2” O.C. screw studs.
❍ Not approved for use in hazardous locations.
Compact Fluorescent
{
The encased ballasts listed on this page
are available in white (001) or black (000)
cans, except CBT’s, which are all in white
cans.
All ballasts are UL listed, CSA approved
See page 4-13 for Dimensions
and Wiring Diagrams.
FOR MORE INFORMATION CALL
PAGE 4-8
1-800-BALLAST
(225-5278)
MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS FOR TWIN, QUAD
AND MULTIPLE LAMPS
13 WATTS
QUICK
REFERENCE
Mag Qty
Line
or
of Line Catalog Input Current
Elec Lamps Volt Number Watts Amps
Lamp Type
Electrical Characteristics - 60 Hz
❍ M
13 Watts
1 120 CF1320H2P ■ 16 0.24
CFT13W/GX23 ❍ M
1 120
4113P
14 0.24
OR
❍ M
1 277 4211F2P ■★ 22 0.16
CFQ13W/GX23 ❍
M
1 277 4211PBES 22 0.16
M
1 120
4112P
14 0.13
M
1 120
4113P
14 0.24
M
1 277 4210PBES 21 0.10
OR
M
2 120
4114P
31 0.26
2 277 4214PBES 26 0.09
Twin or Quad, M
Nominal lamp watts
and configuration
TWIN, QUAD
& MULTIPLE
LAMPS
• Ideal for downlights & wall sconces
• E lectronic models feature universal input
voltage from 120V to 277V. 347V models are
also available.
OR
13 WATTS
• E lectronic models feature programmed rapid start
for excellent lamp performance & auto reset shutdown circuit
Lead Configuration
Starting
Min
Current Ballast Start Power Side Bottom Bottom Starting Wir
Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag
0.30
0.36
0.35
0.35
0.14
0.36
0.11
0.33
0.09
0.85
0.80
1.00
1.00
0.80
0.90
1.00
0.95
0.85
32° F
32° F
32° F
32° F
32° F
32° F
32° F
32° F
32° F
Normal
Normal
Normal
Normal
High
Normal
High
High
High
<15%
<10%
<10%
<10%
<20%
<10%
<20%
<20%
<20%
X
X
X
X
X
X
X
X
X
—
—
—
—
X
X
X
—
—
—
—
—
—
X
X
X
X
X
PH
PH
PH
PH
PH
PH
PH
PH
PH
B10
C2
B3
C3
C2
C2
C3
C5
C4
1
1
1
1
2
1
2
8
9
2-Pin
U.S. type
Lamp Type
13 Watts
CFQ13W/G24q
OR
CFM13W/GX24q
120
E
1
C213UNV ◆r 18
277
120
E
2
C213UNV ◆r 30
277
1
18
E
347 C213/347◆
2
33
0.15
<10%
—— 1.00 0° F High
X
X
X
PRS C10
0.07
<15%
0.26
—— 1.00 0° F High <10% X
X
X
PRS C10
0.11
0.06 —— 1.00
0°F High <10% X
X
X
PRS C10
0.10 —— 0.98
18
19
18
19
OR
Quad or
Multiple,
4-Pin
Lamp Type
13 Watts
CFT13W/2GX7
E 1
E
2
120
CT213UNV ◆ 15
277
120
CT213UNV ◆ 26
277
0.12
<10%
—— 0.98 0°F High
X
0.06
<12%
0.22
—— 0.98 0°F High <10% X
0.10
X
X
PRS C10 20✛
X
X
PRS C10
20
Non-thermally
{
See page 4-13 for Dimensions
and Wiring Diagrams.
PAGE 4-9
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Compact Fluorescent
protected models available.
The encased ballasts listed on this page
are available in white (001) or black (000)
✿ PH = Preheat; PRS = Programmed Rapid Start; RS=Rapid Start
cans,
except CBT’s, which are all in white
F2 indicates an open core & coil unit with mounting feet.
cans.
H2 indicates clamped & covered core & coil with mounting feet.
Twin T4,
All ballasts are UL listed, CSA approved
■ ◆ Add following suffix for complete catalog #: “SE” for Side Exit
4-Pin
connectors, “BE” for Bottom Exit connectors, “BES”
for Bottom Exit connectors with 2˝ O.C. screw studs, "ME" for
Multi Exit connectors, or "MES" for Multi Exit with 2" OC screw studs.
❍ Not approved for use in hazardous locations.
rAdd “ME000K” suffix for Mult-E Kit. For Distribution only.
TWIN, QUAD
& MULTIPLE
LAMPS
• Ideal for downlights, surface
mount & outdoor fixtures
• E lectronic models feature universal input voltage from
120V to 277V. 347V models are also available.
• Electronic models feature programmed rapid start
for excellent lamp performance
& auto reset shutdown circuit
OR
18 WATTS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
18 Watts
CFQ18W/G24d
Mag Qty
Line
or
of Line Catalog Input Current
Elec Lamps Volt Number Watts Amps
Electrical Characteristics - 60 Hz
M
2 120 4122PBES 50 0.45
MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS FOR TWIN, QUAD
AND MULTIPLE LAMPS
18 WATTS
Lead Configuration
Starting
Min
Current Ballast Start Power Side Bottom Bottom Starting Wir
Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag
0.27
0.88 15° F High <20% —
—
X
PH
C6 10
Quad, 2-Pin
Lamp Type
18 Watts
CFQ18W/G24q
OR
CFM18W/GX24q
OR
120
E
1
C218UNV ◆r 19
277
120
E
2
C218UNV◆r 35
277
1
21
E
347 C218/347◆
2
38
0.16
<10%
—— 1.00 0° F High
X
X
X
PRS C10
0.07
<15%
0.30
—— 0.95 0° F High <10% X
X
X
PRS C10
0.13
0.11 —— 1.00
0°F High <10% X
X
X
PRS C10
0.06 —— 0.98
18
19
18
19
Quad or
Multiple, 4-Pin
Lamp Type
18 Watts
FT18W/2G11RS
E
1
E
2
120
CT218UNVSE◆ 23
277
120
43
CT218UNVSE◆
277
42
0.19
0.07
0.37
0.16
——
——
1.00
0.98
0° F
0° F
High <10% X
High <10% X
__
PRS C10 18
__
__
PRS C10 19
The encased ballasts listed on this page are
available in white (001) or black (000) cans,
except CBT’s, which are all in white cans.
All ballasts are UL listed, CSA approved and
designated Class P (thermally protected),
Type HL.
Compact Fluorescent
✿ PH = Preheat; PRS = Programmed Rapid Start; RS=Rapid Start
◆ Add following suffix for complete catalog #: “SE” for Side Exit
connectors, “BE” for Bottom Exit connectors, “BES”
Twin T5,
for Bottom Exit connectors with 2˝ O.C. screw studs, "ME" for
4-Pin,
Multi Exit connectors, or "MES" for Multi Exit with 2" OC screw
studs.
rAdd “ME000K” suffix for Mult-E Kit. For Distribution only.
__
See page 4-13 for Dimensions
and Wiring Diagrams.
FOR MORE INFORMATION CALL
PAGE 4-10
1-800-BALLAST
(225-5278)
MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS
• Ideal for downlights, surface
mount & outdoor fixtures
• Electronic models feature universal input
voltage from120V to 277V. 347V models
are also available.
• Electronic models feature programmed
rapid start for excellent lamp performance
& auto reset shutdown circuit
FOR QUAD AND MULTIPLE LAMPS
26 AND 28 WATTS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
26 Watts
CFQ26W/G24d
Quad, 2-Pin
Lamp Type
26 Watts
CFQ26W/G24q
OR
CFM26W/GX24q
OR
Mag Qty
Line
or of Line
Catalog
Input Current
Elec Lamps Volt
Number
Watts Amps
Electrical Characteristics - 60 Hz
M 1 120 4124PBES
30 0.27
M 1 120 4124PBES
30 0.27
M 2 120 4128PBES
61 0.55
M 2 277 4226PBES
62 0.22
120
E 1
C2642UNV ◆r 28
277
120
E 2
C2642UNV◆r 56
277
31
1
E
347 C2642/347◆
2
57
120
56
◆
E 2
C242UNV
277
55
E 2 347 C242/347◆ 44
0.25
0.11
0.47
0.21
0.09
0.17
0.46
0.20
0.14
QUAD AND
MULTIPLE
LAMPS
OR
26 & 28 WATTS
Lead Configuration
Starting
Min
Current Ballast Start Power Side Bottom Bottom Starting Wir
Amps Factor Temp Factor THD Exit Exit Exit Studs Method_ Dim Diag
0.46
0.46
0.38
0.34
0.88
0.88
0.90
0.90
——
25° F
25° F
32° F
32° F
High
High
High
High
<30%
< 30%
<20%
<20%
—
—
X
X
X
—
—
—
—
X
X
X
PH
PH
PH
PH
C4
C4
C6
C4
3
3
16
8
1.02 0° F
High <10% X
X
X
PRS C10 18
——
0.98 0° F
High <10% X
X
X
PRS C10 19
——
——
1.02
18
0°F High <10% X
X
X
PRS C10
0.98 19
——
1.02 0° F
High <10% X
X
X
PRS C11 19
——
1.02 0° F
High <10% X
X
X
PRS C11 19
Quad or
Multiple,
4-Pin
❍ M 1 120
4139F2P■
32 0.65 0.84 0.95 15° F Normal <10% X
—
—
PH B3 1
Lamp Type
28 Watts
CFQ28W/GX32d
✿ PH = Preheat; PRS = Programmed Rapid Start; RS = Rapid Start
The encased ballasts listed on this page
■ F2 indicates an open core & coil unit with mounting feet.
are available in white (001) or black (000)
cans, except CBT’s, which are all in white
◆ Add following suffix for complete catalog #: “SE” for Side Exit
cans.
connectors or “BE” suffix for Bottom Exit connectors or “BES”
All ballasts are UL listed, CSA approved
for Bottom Exit connectors with 2˝ O.C. screw studs.
T5 Quad, 2-Pin
❍ Not approved for use in hazardous locations.
rAdd “ME” suffix for Mult-E Kit. For Distribution only.
µ Add “B” for Bottom Exit or “S” for Side Exit or “BS” for
Bottom Exit with 2” O.C. screw studs.
Compact Fluorescent
See page 4-13 for Dimensions
and Wiring Diagrams.
PAGE 4-11
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
MULTIPLE
LAMPS
32, 42, 57 & 70 WATTS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
32 Watts
CFM32W/GX24q
Multiple, 4-Pin
Lamp Type
42 Watts
CFM42W/GX24q
Multiple, 4-Pin
Lamp Type
57 Watts
CFM57W/GX24q
Multiple, 4-Pin
Compact Fluorescent
Lamp Type
70 Watts
CFM70W/GX24q
ELECTRONIC
COMPACT FLUORESCENT
BALLASTS FOR MULTIPLE LAMPS
• Ideal for downlights, surface mount &
outdoor fixtures
• E lectronic models feature universal input
voltage from 120V to 277V. 347V models
are also available.
• Electronic models feature programmed
rapid start for excellent lamp performance
& auto reset shutdown circuit
Mag Qty
Line
or of Line
Catalog✪
Input Current
Elec Lamps Volt
Number
Watts Amps
Electrical Characteristics - 60 Hz
120
0.30
E 1
C2642UNV◆r 36
277
0.13
E 1 347 C2642/347◆ 36 0.11
120
69 0.58
E 2
C242UNV◆
277
67 0.26
E 2 347 C242/347◆
62 0.19
E 1
E 1
E 1
E 2
E 1
E 2
E 1
E 1
120
C2642UNV◆r 48
277
347 C2642/347◆ 50
120
C242UNV◆
45
277
120
91
C242UNV◆
277
90
347 C242/347◆
42
347 C242/347◆
80
120
58
◆
C242UNV
277
57
347 C242/347◆
61
E 1
E 1
120
C242UNV◆
277
347 C242/347◆
0.41
0.18
0.15
0.40
0.18
0.76
0.32
0.13
0.25
0.52
0.21
0.18
32, 42, 57 & 70 WATTS
Lead Configuration
Starting
Min
Current Ballast Start Power Side Bottom Bottom Starting Wir
Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag
——
1.00 0° F
High <10% X
X
X
——
0.98 0° F
High <10% X
X
X
PRS C10 18
——
1.00 0° F
High <10% X
X
X
PRS C11 19
——
1.00 0° F
High <10% X
X
X
PRS C11 19
——
0.98 0° F
High <10% X
X
X
PRS C10 18
——
1.00 0° F
High <10% X
X
X
PRS C10 18
——
1.00 0° F
High <10% X
X
X
PRS C11 19
——
0.98 0° F
High <10% X
X
X
PRS C11 19
——
——
1.00 0° F
0.98 0° F
High <10% X
High <10% X
X
X
X
X
PRS C11 18
PRS C11 19
——
1.00 0° F
High <10% X
X
X
PRS C11 19
——
1.00 0° F
High < 10% X
X
X
PRS C11 19
1.00 0° F
High <10% X
X
X
PRS C11 19
1.00 0° F
High < 10% X
X
X
PRS C11 19
73 0.61
——
72 0.27
74 0.21 ——
PRS C10 18
Multiple, 4-Pin
✿ RS = Rapid Start; PRS = Programmed Rapid Start
The encased ballasts listed on this page are
◆
Add following suffix for complete catalog #: “SE” for Side Exit
available in white (001) or black (000) cans.
connectors or “BE” suffix for Bottom Exit connectors or “BES” All ballasts are UL listed, CSA approved and
designated Class P (thermally protected), Type
for Bottom Exit connectors with 2˝ O.C. screw studs.
HL.
rAdd “ME” suffix for Mult-E Kit. For Distribution only.
µ Add “B” for Bottom Exit or “S” for Side Exit or “BS” for
Bottom Exit with 2” O.C. screw studs.
See page 4-13 for Dimensions
and Wiring Diagrams.
FOR MORE INFORMATION CALL
PAGE 4-12
1-800-BALLAST
(225-5278)
TWIN, TRIPLE,
QUAD &
MULTIPLE
LAMPS
MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS
WIRING DIAGRAMS AND DIMENSIONS
REFERENCE DRAWING FOR B1-B3
WIRING DIAGRAMS
C
D
Install in accordance with
National Electrical Code.
B
A
E
Dwg.
A
B1
B2
B3
0.84”
1.23”
1.50”
B
C
1.41”
1.64”
1.95”
D
1.72”
1.97”
2.34”
E
2.00”
2.38”
2.81”
2.38”
2.81”
3.25”
Black
Lead Lengths: 10˝-12˝
REFERENCE DRAWING FOR C1, C2
E
C
B
Dwg.
C1
C2
REFERENCE DRAWING FOR C3, C4, C5
D
A
A
B
17/64"
A
B
C
D
E
1.84”
1.84”
1.09”
1.42”
2.06”
2.40”
2.41”
2.75”
2.75”
3.13”
B
C
D
E
F
C3
C4
C5
2.14”
2.34”
1.88”
1.56”
1.53”
1.47”
3.50”
5.45”
5.13”
4.31”
6.00”
6.00”
4.75”
6.59”
6.44”
0.22”
0.31”
0.25”
Dwg.
C6
A
B
2.38” 1.53”
C
F
A
111/16"
F
5/16"
C
D
8.31”
8.89”
E
F
9.48” 1.19”
Dwg.
C10
A
B
Black
C
Line
D
E
F
Red
DIAGRAM 3
G
Leadless-Poke-in wire connection
White
Blue
BALLAST
Blue
Line
Black
Blue
E
F
DIAGRAM 8
Parallel lamp operation
White
Red
BALLAST
BALLAST
Line Black
Blue
DIAGRAM 17
Series lamp operation
G
C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.55” 1.00”
Leadless-Poke-in wire connection
White
BALLAST
Black
White
Green
REFERENCE DRAWING FOR CBT
Red
Red
BALLAST
Blue
Blue
DIAGRAM 18
Ballast should be groundBlack
White
Green
BALLAST
Red
Red
Yellow
Yellow
Blue
Blue
DIAGRAM 19
Series lamp operation
Ballast should be grounded
Black
Blue
Line
DIAGRAM 9
Series lamp opera-
Red
White
Green
Black
Red
BALLAST
Yellow
Yellow
Blue
Blue
White
Red
BALLAST
Black
Blue
Line
DIAGRAM 10
Parallel lamp operation
Dwg.
A
B
C
D
E
CBT
3.86”
2.00”
1.00”
3.50”
——
DIAGRAM 20
Series lamp opera-
PAGE 4-13
DIAGRAM 47
DIAGRAM 48
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Compact Fluorescent
Black
DIAGRAM 16
Series lamp operation
D
Blue
BALLAST
2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00”
White
C
DIAGRAM 2
White
D
E
Line
B
Line
G
REFERENCE DRAWING FOR C11
A
Blue
BALLAST
Black
B
Lead Lengths: Side
• Black/White–
11˝
• Red/Blue–12˝
BE/BES–8˝
Dwg.
White
Lead Lengths: Side–12˝
BE/BES–8˝
E
D
A
F
15/ "
16
A
REFERENCE DRAWING FOR C10
REFERENCE DRAWING FOR C6
B
DIAGRAM 1
Dwg.
Lead Lengths: Side–12˝
BE/BES–8˝
C
Line
E
D
C
3/ "
16
BALLAST
Black
2D
LAMPS
• Ideal for surface mount fixtures
• All magnetic models are encased & potted.
• Magnetic and electronic models available.
• E lectronic models feature universal input voltage
from 120V to 277V. 347V models are also available.
• Electronic models feature programmed
rapid start for excellent lamp performance
& auto reset shutdown circuit
10, 16 & 21
WATTS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
10 Watts
CFS10W/GR10q
2D, 4-Pin
Lamp Type
16 Watts
CFS16W/GR10q
2D, 4-Pin
Lamp Type
21 Watts
CFS21W/GR10q
Compact Fluorescent
2D, 4-Pin
MAGNETIC & ELECTRONIC
COMPACT FLUORESCENT
BALLASTS FOR 2D LAMPS
10, 16 AND 21 WATTS
Lead Configuration
Mag Qty
Line Starting
Min
or
of Line Catalog Input Current Current Ballast Start Power Side Bottom Bottom Starting Wir
Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag
Electrical Characteristics - 60 Hz
120
0.12
<10%
E
1
C213UNV◆r 15
—— 1.02 0° F High
X
X
X
PRS C10 18a
277
0.06
<15%
120
0.22
E
2
C213UNV◆r 26
—— 1.02 0° F High <10% X
X
X
PRS C10 19a
277
0.10
E
1 347 C213/347◆ 16 0.05 —— 1.02 0° F High <10% X
X
X
PRS C10 18a
E
2 347 C213/347◆ 28 0.08 —— 1.02 0° F High <10% X
X
X
PRS C10 19a
E 1
E 1
E 2
E 2
120
C213UNV◆r 19
277
20
347 C213/347◆
120
C213UNV◆r 33
277
347 C213/347◆
34
0.15
—— 0.95 0° F High
0.07
0.06 —— 0.95 0°F High
0.28
—— 0.95 0° F High
0.12
0.10 —— 0.95 0°F High
<10%
X
<15%
<10% X
X
X
PRS C10 18a
X
X
PRS C10 18a
<10% X
X
X
PRS C10 19a
<10% X
X
X
PRS C10 19a
E
1
E
1
E
2
E
2
120
C218UNV◆r 24
277
347 C218/347◆ 21
120
C218UNV◆r 43
277
347 C218/347◆ 39
0.18
—— 0.98 0° F High
0.08
0.06 —— 0.98 0° F High
0.37
—— 0.95 0° F High
0.16
0.12 —— 0.95 0° F High
<10%
<15%
<10%
<10%
<15%
<10%
X
X
X
PRS C10 18a
X
X
X
PRS C10 18a
X
X
X
PRS C10 19a
X
X
X
PRS C10 19a
● Starter required: use COP-40 or FS-4 type fluorescent starter.
✿ PH = Preheat; PRS = Programmed Rapid Start
◆ Add following suffix for complete catalog #: “SE” for Side Exit
connectors, “BE” for Bottom Exit connectors, “BES” for Bottom
Exit connectors with 2˝ O.C. screw studs, "ME" for Multi Exit
connectors, or "MES" for Multi Exit with 2" OC screw studs.
rAdd “ME000K” suffix for Mult-E Kit. For Distribution only.
The encased ballasts listed on this page are
available in white (001) or black (000) cans.
All ballasts are UL listed, CSA approved and
designated Class P (thermally protected), Type
HL.
See page 4-16 for Dimensions
and Wiring Diagrams.
PAGE 4-14
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
MAGNETIC & ELECTRONIC
COMPACT FLUORESCENT
BALLASTS FOR 2D LAMPS
28, 38 & 55 WATTS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
28 Watts
CFS28W/GR8
2D, 2-Pin
Lamp Type
28 Watts
CFS28W/GR10q
Mag Qty
Line
or of Line
Catalog✪
Input Current
Elec Lamps Volt
Number
Watts Amps
Electrical Characteristics - 60 Hz
M 1 120 4124PBES
37 0.34
M 1 120 4124PBES
37 0.34
M 2 120 4128PBES
61 0.55
M 2 277 4226PBES
66 0.23
E 1
E 1
E 2
E 2
120
C2642UNV◆r 31
277
347 C2642/347◆ 33
64
120
C242UNV◆
277
63
347 C242/347◆
60
0.27
0.12
0.10
0.54
0.24
0.18
E 1
120
C2642UNV◆r 33
277
0.27
0.12
2D
LAMPS
• Ideal for surface mount fixtures
• All magnetic models are encased & potted
• Magnetic & electronic models available
• E lectronic models feature universal input voltage
from 120V to 277V.
• Electronic models feature programmed
rapid start for excellent lamp performance
& auto reset shutdown circuit
28, 38 & 55
WATTS
Lead Configuration
Starting
Min
Current Ballast Start Power Side Bottom Bottom Starting Wir
Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag
0.46
0.46
0.38
0.34
0.88
0.88
0.90
0.93
——
32° F
32° F
32° F
25° F
High
High
High
High
<20%
<20%
<20%
<20%
—
—
X
X
X
—
—
—
—
X
X
X
PH
PH
PH
PH
C4
C4
C6
C4
1a
1a
13a
7a
0.95 0° F
High <10% X
X
X
PRS C10 18a
——
0.95
0°F
High <10% X
X
X
PRS C10 18a
——
1.00 0° F
High <10% X
X
X
PRS C11 19a
——
1.00
0°F
High <10% X
X
X
PRS C11 19a
——
0.80
0°F
High <10% X
—
X
PRS C10 18a
2D, 4-Pin
Lamp Type
38 Watts
CFS38W/GR10q
2D, 4-Pin
✿ PH = Preheat; PRS = Programmed Rapid Start
◆ Add following suffix for complete catalog #: “SE” for Side Exit
connectors or “BE” suffix for Bottom Exit connectors or “BES”
for Bottom Exit connectors with 2˝ O.C. screw studs.
rAdd “ME” suffix for Mult-E Kit. For Distribution only.
The encased ballasts listed on this page are
available in white (001) or black (000) cans.
All ballasts are UL listed, CSA approved and
designated Class P (thermally protected),
Type HL.
Compact Fluorescent
See page 4-16 for Dimensions
and Wiring Diagrams.
FOR MORE INFORMATION CALL
PAGE 4-15
1-800-BALLAST
(225-5278)
MAGNETIC & ELECTRONIC COMPACT
FLUORESCENT BALLASTS FOR
2D LAMPS
2D
LAMPS
WIRING DIAGRAMS AND DIMENSIONS
WIRING DIAGRAMS
REFERENCE DRAWING FOR C4, C5
Install in accordance with
National Electrical Code.
E
D
C
A
B
F
15/16"
Dwg.
A
B
C
D
E
F
C4
C5
2.34”
1.88”
1.53”
1.47”
5.45”
5.13”
6.00”
6.00”
6.59”
6.44”
0.31”
0.25”
White
White
Black
Lead Lengths: Side–12˝
BE/BES–8˝
Red
BALLAST
Black
Blue
BALLAST
White
Blue
Blue
Black
DIAGRAM 7a
Parallel lamp opera-
DIAGRAM 1a
E
D
A
B
Dwg.
A
B
C6 2.40” 1.55”
Line
DIAGRAM 13a
Series lamp operation
S
D
E
8.31”
8.89”
Black
White
Green
9.50” 1.19”
F
A
Blue
White
DIAGRAM 5a
Black
BALLAST
BALLAST
DIAGRAM 18a
Blue
Line
DIAGRAM 9a
Parallel lamp operation
Black
White
BALLAST
Red
Red
Yellow
Yellow
Blue
Blue
D
E
D
Blue
Blue
Blue
Green
C
Red
Red
G
B
Compact Fluorescent
White
BALLAST
Line
REFERENCE DRAWING FOR C10
B
FS-4
F
Black
A
S
FS-4
5/16"
Lead Lengths: Side–12˝
BE/BES–8˝
Dwg.
S
FS-4
111/16"
F
C
C
Blue
Line
Line
REFERENCE DRAWING FOR C6
C
Red
BALLAST
E
C10 2.31” 1.00” 4.25” 4.61” 4.94”
F
G
0.98”
1.00”
DIAGRAM 19a
Series lamp operation
Leadless-Poke-in wire connection
REFERENCE DRAWING FOR C11
Dwg.
A
B
C
D
E
F
G
C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.55” 1.00”
Leadless-Poke-in wire connection
FOR MORE INFORMATION CALL
PAGE 4-16
1-800-BALLAST
(225-5278)
ELECTRONIC COMPACT
FLUORESCENT BALLASTS
22, 40 & 55 WATTS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
22 Watts
FC9T5-22W
T5 CIRCULAR
Lamp Type
40 Watts
FC12T5-40W
T5 CIRCULAR
Lamp Type
22 & 40 Watts
FC9T5-22W &
FC12T5-40W
T5
CIRCULAR
LAMPS
• Ideal for surface mount fixtures
• E lectronic models feature universal input
voltage from 120V to 277V. 347V models
are also available.
• Electronic models feature rapid and programmed
rapid start for excellent lamp performance
& auto reset shutdown circuit
Mag Qty
Line
or of Line
Catalog✪
Input Current
Elec Lamps Volt
Number
Watts Amps
Electrical Characteristics - 60 Hz
120
0.21
E 1
C2642UNV◆r 25
277
0.10
E 1 347 C2642/347◆ 26 0.08
E 2
E 2
120
C242UNV◆
50
277
347 C242/347◆
47
0.42
0.19
0.14
E 1
E 1
E 2
E 2
120
C2642UNV◆r 42
277
347 C2642/347◆ 40
80
120
C242UNV◆
277
79
347 C242/347◆
71
0.35
0.16
0.12
0.65
0.29
0.22
22,40 & 55 WATTS
WIRING DIAGRAMS
Lead Configuration
Starting
Min
Current Ballast Start Power Side Bottom Bottom Starting Wir Install in accordance with
Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag National Electrical Code.
——
1.00 0° F
High <10% X
X
X
PRS C10 28
——
0.98 0° F
High <10% X
X
X
PRS C10 28
——
1.05 0° F
High <10% X
X
X
PRS C11 23
——
1.05 0° F
High <10% X
X
X
PRS C11 23
——
0.98 0° F
High <10% X
X
X
PRS C10 28
——
0.98 0° F
High <10% X
X
X
PRS C10 28
——
0.98 0° F
High <10% X
X
X
PRS C11 23
——
0.98 0° F
High <10% X
X
X
PRS C11 23
Black
White
Green
E 2
T5 CIRCULAR
Lamp Type ❍
E 1
55 Watts
FC12T5-55W
❍ E
2
120
C242UNV◆
277
66
64
120
C242/347◆
59
277
120
B254PUNV-D 56
277
120
106
B254PUNV-D
277
103
0.54
0.24
0.18
Yellow
Blue
DIAGRAM 23
Series lamp operation
Black
White
Green
E 2
Red
BALLAST
Red
BALLAST
Blue
——
0.98 0° F
High <10% X
X
X
PRS C11 23
——
0.98 0° F
High <10% X
X
X
PRS C11 23
0.87 0° F
High <10% X
—
—
PRS
-D 28
0.85 0° F
High <10% X
—
—
PRS
-D 23
0.46
——
0.21
0.88
——
0.38
DIAGRAM 28
DIAGRAM 47
✿ PRS = Programmed Rapid Start; RS=Rapid Start
◆ Add following suffix for complete catalog #: “SE” for Side Exit
connectors or “BE” suffix for Bottom Exit connectors or “BES”
for Bottom Exit connectors with 2˝ O.C. screw studs.
µ Add “B” for Bottom Exit or “S” for Side Exit or “BS” for
Bottom Exit with 2” O.C. screw studs.
❍ Not approved for use in hazardous locations.
Compact Fluorescent
T5 CIRCULAR
The encased ballasts listed on this page are
available in white (001) or black (000) cans, except
CBT’s, which are all in white cans.
All ballasts are UL listed, CSA approved and
designated Class P (thermally protected).
REFERENCE DRAWING FOR C11
REFERENCE DRAWING FOR C10
C
F
A
G
B
Dwg.
D
E
A
B
C
D
E
F
G
C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.56” 1.00”
Dwg.
A
B
C
D
E
F
G
C10 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00”
Leadless-Poke-in wire connection
Leadless-Poke-in wire connection
REFERENCE DRAWING FOR CBT
REFERENCE DRAWING FOR -D
Dwg.
-D
L
W
16.88”
1.16”
H
M
1.00” 16.28”
X
---
PAGE 4-17
Dwg.
A
B
C
D
E
CBT
3.86”
2.00”
1.00”
3.50”
——
LONG TWIN
T5 LAMPS
• Ideal for track light & surface mount fixtures
• Electronic models feature universal input
voltage from 120V to 277V. 347V models are also
available
• Electronic models feature rapid and
programmed rapid start for excellent lamp performance & auto reset shutdown circuit
18, 24/27 WATTS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
18 Watts
FT18W/2G11/RS
Long Twin T5,
4-Pin
Mag Qty
Line Starting
or
of Line Catalog Input Current Current Ballast
Elec Lamps Volt Number Watts Amps Amps Factor
Electrical Characteristics - 60 Hz
E 1 120 CBT126L-120µ 20 0.36 —— 1.10
120
0.19 ——
E 1
CT218UNVSE 23
1.00
277
0.07 ——
120
43 0.37 ——
E 2
CT218UNVSE
0.98
277
42 0.16 ——
1
❍ E
2
E
1
E
2
Long Twin T5,
E
2
4-Pin
E
1
E
2
Lamp Type
24/27 Watts
FT24W/2G11/RS
Lamp Type
24/27 Watts
CFM24W/2G10
Compact Fluorescent
T5 F-Lamp,
4-Pin
❍ E
120
B224PUNV-C 27
277
120
52
B224PUNV-C
277
51
347 C2642/347◆ 29
120
51
C242UNV◆
277
50
347 C242/347◆ 49
120
C2642UNV 26
277
120
47
C2642UNV
277
49
ELECTRONIC
COMPACT FLUORESCENT BALLASTS
FOR LONG TWIN T5 LAMPS
18 AND 24/27 WATTS (BIAX, DULUX L AND PLL)
Lead Configuration
Min
Start Power Side Bottom Bottom Starting Wir
Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag
0° F Normal <150%
High <10%
High <10%
X
X
X
X
X
X
—
—
—
—
X
—
—
—
—
RS
PRS
PRS
PRS
PRS
<10%
X
<15%
—
—
PRS
-C 29
<10% X
—
—
PRS
-C 29
0° F
0° F
0.23
—— 1.05 0° F High
0.10
0.43
—— 1.00 0° F High
0.18
0.09 —— 0.90 0° F High
0.43
—— 1.02 0° F High
0.19
0.14 —— 1.02 0° F High
0.22
—— 1.01 0° F High
0.10
0.40
—— 0.98 0° F High
0.18
CBT
C10
C10
C10
C10
47
21
21
20
20
<10% X
X
X
PRS C10 21
<10% X
X
X
PRS C11 20
<10% X
X
X
PRS C11 20
<10% X
X
X
PRS C10 21
<10% X
X
X
PRS C10 21
120
0.20
<10%
1
B224PUNV-C 24
—— 1.05 0° F High
X
—
—
PRS -C 29
277
0.09
<15%
120
48 0.40
❍ E
2
B224PUNV-C
—— 1.00 0° F High <10% X
—
—
PRS -C 29
277
47 0.17
✿ RS = Rapid Start; PRS = Programmed Rapid Start
The encased ballasts listed on this page
❍ E
❍ Not approved for use in hazardous locations.
◆
Add following suffix for complete catalog #: “SE” for Side Exit
connectors or “BE” suffix for Bottom Exit connectors or “BES”
for Bottom Exit connectors with 2˝ O.C. screw studs.
rAdd “ME” suffix for Mult-E Kit. For Distribution only.
µ Add “B” for Bottom Exit or “S” for Side Exit or “BS” for
Bottom Exit with 2” O.C. screw studs.
are available in white (001) or black (000)
cans, excpet CBT’s, which are all in white
cans.
All ballasts are UL listed, CSA approved
See pages 4-21 and 4-22 for
Dimensions and Wiring Diagrams.
FOR MORE INFORMATION CALL
PAGE 4-18
1-800-BALLAST
(225-5278)
ELECTRONIC
LONG TWIN T5 BALLASTS
LONG TWIN
T5 LAMPS
• Ideal for track light & surface mount fixtures
• New electronic 1 & 2 lamp models for 24 watt lamps
• Electronic models feature universal input voltage
from 120V to 277V. 347V models are also available.
• Electronic models feature programmed rapid start for
excellent lamp performance & auto reset shutdown circuit
36/39 AND 40 WATTS
(BIAX, DULUX L AND PLL)
36/39 & 40
WATTS
QUICK
REFERENCE
Lead Configuration
Mag Qty
Line Starting
Min
or
of Line Catalog Input Current Current Ballast Start Power Bottom Bottom Starting Wir
Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD Side Exit Exit Studs Method✿ Dim Diag
Lamp Type
Electrical Characteristics - 60 Hz
36/39 Watts
120
0.30 ——
❍ E 1
B224PUNV-C• 36
0.95 0° F High <10% X
PRS -C 29
—
—
FT36W/2G11/RS
277
0.13 ——
120
71
0.59
——
❍ E
2
B239PUNV-D•
0.97 0° F High <10% X
PRS -D 29
—
—
277
70 0.26 ——
120
0.37
❍ E
1
B254PUNV-D£ 44
—— 1.22 0° F High <10% X
—
—
PRS -D 28
277
0.17
Long Twin T5, ❍
120
90 0.75
E
2
B254PUNV-D
—— 1.20 0° F High <10% X
—
—
PRS -D 23
4-Pin
277
88 0.32
120
0.29
< 10%
❍ E
1
C242UNV◆ 34
—— 0.88 0° F High
X
X
X
PRS C11 20
277
0.14
< 20%
120 ◆
0.43 ——
E
2
C242UNV• 64
0.83 0° F High <10% X
X
X
PRS C11 20
277
0.19 ——
◆
E
2 347 C242/347• 64 0.19 —— 0.90 0° F High <10% X
X
X
PRS C11 20
Nominal lamp watts
and configuration
Lamp Type
36/39 Watts
CFM36W/2G10
T5 F-Lamp,
4-Pin
E
1
E
1
E
1
E
2
❍ E
❍ E
120 C240SI120RH 40
277 C240SI277RH 40
120
41
C240PUNVHP-B•
277
40
120
93
◆
C242UNV
277
87
120 C340SI120RH 75
277 C340SI277RH 75
120 C240SI120RH 67
277 C240SI277RH 67
76
120
C240PUNVHP-B•
277
73
120
◆
C242UNV
47
277
120 C340SI120RH 98
277 C340SI277RH 98
0.28
0.12
0.27
0.12
0.28
0.14
0.57
0.25
——
0.95
0° F
High <10% X
—
—
PRS
-C 29
——
0.98 0° F High <10% X
X
X
PRS C10 21
——
—— 0.98 0° F High <15% X
X
X
PRS C11 20
——
——
0.90
0° F
High <10% X
X
X
PRS C11 20
0.40 —— 1.02 50° F High <20% X
—
—
IS
C6 12✛
0.17 —— 1.02 50° F High <20% X
—
—
IS
C6 12✛
0.34
—— 1.00 0° F High <10% X
—
—
PRS -B 20
0.15
0.78
—— 1.00 0° F High <10% X
X
X
PRS C11 20
0.34
0.68 —— 0.99 50° F High <20% X
—
—
IS
C6 14 ✛
0.30 —— 0.99 50° F High <20% X
—
—
IS
C6 14✛
0.61 —— 0.88 50°F High <20% X
—
—
IS
C6 12
0.27 —— 0.88 50°F High <20% X
—
—
IS
C6 12
0.63
—— 0.90 0° F High <10% X
—
—
PRS -B 20
0.27
0.40
—— 1.08 0° F High <10% X
X
X
PRS C11 20
0.18
0.88 —— 0.88 50° F High <20% X
—
—
IS
C6 14
0.39 —— 0.88 50° F High <20% X
—
—
IS
C6 14
✿ PRS = Programmed Rapid Start; IS = Instant Start
◆ Add following suffix for complete catalog #: “SE” for Side Exit
connectors or “BE” suffix for Bottom Exit connectors or “BES”
for Bottom Exit connectors with 2˝ O.C. screw studs.
❍ Not approved for use in hazardous locations.
£Consult lamp manufacturers for applications with Ballast Factor >1.20.
rAdd “ME” suffix for Mult-E Kit. For Distribution only.
The encased ballasts listed on this page
are available in white (001) or black (000)
cans.
All ballasts are UL listed, CSA approved
See pages 4-21 and 4-22 for
Dimensions and Wiring Diagrams.
FOR MORE INFORMATION CALL
PAGE 4-19
1-800-BALLAST
(225-5278)
Compact Fluorescent
1
1
E
1
E
2
❍ E
2
Long Twin T5, ❍ E
2
4-Pin
2
❍ E
2
❍ E
E
2
E
1
3
❍ E
3
❍ E
Lamp Type
40 Watts
FT40W/2G11
120
B224PUNV-C• 34
277
120
C2642UNV◆r 32
277
120
C242UNV◆ 33
277
120
68
C242UNV•◆r
277
67
ELECTRONIC
LONG TWIN
T5 LAMPS
• Ideal for track light & recessed fixtures
• Electronic models for 1, 2, 3 & 4 lamp applications
• Programmed Rapid & Instant Starting Options
• Models feature auto reset shutdown circuit
50, 55 & 80 WATTS
ELECTRONIC
LONG TWIN T5 BALLASTS
50, 55 AND 80 WATTS
(BIAX, DULUX L AND PLL)
QUICK
REFERENCE
Lead Configuration
Mag Qty
Line Starting
Min
or
of Line
Catalog
Input Current Current Ballast Start Power Side Bottom Bottom Starting Wir
Elec Lamps Volt
Number
Watts Amps Amps Factor Temp Factor THD Exit Exit Exit Studs Method_ Dim Diag
Electrical Characteristics - 60 Hz
Lamp Type
120
60 0.50
50 Watts
m E
1
B254PUNV-D
—— 1.12 0° F High <10% X
—
—
PRS -D 29
277
59 0.22
FT50W/2G11
120
112 1.00
m E
2
B254PUNV-D
—— 1.10 0° F High <10% X
—
—
PRS -D 29
277
109 0.43
m E
1 347 B254P347-D 58 0.17 —— 1.12 0° F High <10% X
—
—
PRS -D 27
m E
2 347 B254P347-D 106 0.31 —— 1.10 0° F High <10% X
—
—
PRS -D 27
347
0.19
<10%
Long Twin T5, E
1
B254PHRVHB-E 65
—— 1.12 0° F High
X
—
—
PRS -E 42
480
0.15 <15%
4-Pin
347
115 0.33
E
2
B254PHRVHB-E
—— 1.10 0° F High <10% X
—
—
PRS -E 41
480
114 0.25
120
180 1.51
E
3
B454PUNV-E
—— 1.13 0° F High <10% X
—
—
PRS -E 44
277
178 0.65
120
233 1.87
E
4
B454PUNV-E
—— 1.10 0° F High <10% X
—
—
PRS -E 44
277
225 0.80
120
240 1.98
E
4
B454PUNVHB-E
—— 1.10 0° F High <10% X
—
—
PRS -E 44
277
235 0.84
Nominal lamp watts
and configuration
Lamp Type
55 Watts
FT55W/2G11
Compact Fluorescent
Long Twin T5,
4-Pin
Lamp Type
80 Watts
FT80W/2G11
E
1
E
2
E
1
E
2
E
1
E
1
E
1
E
2
E
3
E
4
E
4
120
B254PUNV-D 58
277
120
112
B254PUNV-D 109
277
347 B254P347-D 57
347 B254P347-D 102
120
C242UNVu 46
277
347 C242/347u 43
347
B254PHRVHB-E 61
480
347
109
B254PHRVHB-E 108
480
120
170
B454PUNV-E 167
277
120
223
B454PUNV-E 217
277
120
229
B454PUNVHB-E 223
277
0.48
—
—
PRS -D 29
0.22 —— 0.92 0° F High <10% X
0.93
—
—
PRS -D 29
0.40 —— 0.90 0° F High <10% X
0.17 —— 0.92 0° F High <10% X
—
—
PRS -D 27
0.30 —— 0.90 0° F High <10% X
—
—
PRS -D 27
0.38
——
0.83
0°
F
High
<10%
X
X
X
PRS
C11 21
0.17
0.13 —— 0.83 0° F High <10% X
X
X
PRS C11 21
0.19
<10%
——
0.92
0°
F
High
X
—
—
PRS -E 42
0.14 <15%
0.33
—
—
PRS -E 41
0.24 —— 0.90 0° F High <10% X
1.42
—
—
PRS -E 44
0.62 —— 0.93 0° F High <10% X
1.87
—
—
PRS -E 44
0.80 —— 0.90 0° F High <10% X
1.91
—
—
PRS -E 44
0.80 —— 0.90 0° F High <10% X
E
1
120
ES4515K
277
0.74
0.32
88
87
——
1.00 0° F High <10% X
—
—
PRS ESK 43
Long Twin T5,
4-Pin
The encased ballasts listed on this page are available in
white (001) or black (000) cans. All ballasts are UL listed, CSA
_ IS = Instant Start; PRS = Programmed Rapid Start
approved and designated Class P (thermally protected).
u Add following suffix for complete catalog #: “SE” for Side Exit
connectors or “BE” suffix for Bottom Exit connectors or “BES”
for Bottom Exit connectors with 2˝ O.C. screw studs.
m Not approved for use in hazardous locations.
See pages 4-21 and 4-22 for
Dimensions and Wiring Diagrams.
FOR MORE INFORMATION CALL
PAGE 4-20
1-800-BALLAST
(225-5278)
MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS
LONG TWIN
T5 LAMPS
DIMENSIONS
REFERENCE Drawing for -B
REFERENCE Drawing for C6
E
D
C
A
B
Dwg.
-B
L
W
H
M
X
9.50”
1.50”
1.00”
8.89”
0.88”
Dwg.
C6
111/16"
F
5/16"
A
B
C
D
2.40”
1.55”
8.31”
8.89”
E
F
9.50” 1.19”
Lead Lengths: Side
• Black/White–11˝
• Red/Blue–16˝
• Yellow–16˝
REFERENCE Drawing for C10
C
REFERENCE Drawing for C11
F
A
G
B
D
E
Dwg.
A
B
C
D
E
F
G
Dwg.
C10 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00”
A
B
C
D
E
F
G
C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.56” 1.00”
Leadless-Poke-in wire connection
Leadless-Poke-in wire connection
REFERENCE Drawing for CBT
REFERENCE Drawing for -D, -E, ESK
L
W
H
M
-D 16.88” 1.18” 1.00” 16.20”
-E 16.88” 1.74” 1.18” 16.28”
ESK 16.65” 1.24” 1.00” 16.30”
Dwg.
A
B
C
D
E
CBT
3.86”
2.00”
1.00”
3.50”
——
PAGE 4-21
X
-------
Compact Fluorescent
Dwg.
MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS
LONG TWIN
T5 LAMPS
WIRING DIAGRAMS
Black
Red
White
Red
BALLAST
Yellow
Blue
Yellow
Blue
Black
White
Green
Red
BALLAST
Yellow
Blue
DIAGRAM 23
Series lamp operation
Line
DIAGRAM 34
Line
Black
White
DIAGRAM 27
Series lamp operation
Blue
Blue
Red
BALLAST
Black
White
Green
DIAGRAM 12
Parallel lamp operation
Black
White
Line
BALLAST
DIAGRAM 42
For one lamp application, individually cap
yellow and yellow/black leads, insulate to 600V
DIAGRAM 5
Parallel lamp operation
Red
BALLAST
Blue
DIAGRAM 47
DIAGRAM 41
DIAGRAM 28
Blue
Blue
Blue
Red
DIAGRAM 43
DIAGRAM 29
DIAGRAM 14
Parallel lamp operation
Cap unused blue lead; insulate to 600
Compact Fluorescent
;
Black
Red
White
Green
Red
BALLAST
Yellow
Yellow
Blue
Blue
DIAGRAM 44
DIAGRAM 20
Series lamp operation
Red
Black
White
Green
Red
BALLAST
Blue
Blue
Line
DIAGRAM 33
Mount lamp within 1" of grounded metal reflector.
DIAGRAM 21
FOR MORE INFORMATION CALL
PAGE 4-22
1-800-BALLAST
(225-5278)
Ballasts For High Intensity
Discharge Lamps
Universal Means Higher
Expectations In High
Intensity Discharge
Universal Lighting Technologies (“Universal”) offers a
wide array of ballasts for High Intensity Discharge (HID)
lamps. Applications include Metal Halide (MH), Pulse
Start Metal Halide (PSMH), and High Pressure Sodium
(HPS) lamps ranging from 35 to 1500 watts.
We’re the technology leader in every category of
HID ballasts. Our Universal Precise™ line is the latest
innovation in magnetic core & coil technology in years.
HID
Universal offers a complete line of HID ballasts for applications ranging from
35 - 1500 watts.
Universal Lighting Technologies is a subsidiary of
Panasonic Electric Works Co., Ltd., a member of the Panasonic Group
HID
Notes
PAGE 5-2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Product Overview
Core & Coil
Core & coil ballasts are used in over 90% of all HID fixtures. Universal’s core & coil models are available for
all HID lamp types, including single-, dual-, tri-, quad- and multi-volt designs. For added
versatility and reduced inventory costs, Universal has also introduced the industry’s first Multi-5™
ballast (120, 208, 240, 277, or 480 volt), featuring a 480-volt tap on a conventional quad-tap ballast.
Our core & coil models are ideal for a wide variety of lighting applications, including factories,
warehouses, gymnasiums and retail stores. All these ballasts feature precision-wound coils, ensuring even
heat dissipation and the highest electrical integrity.
Universal’s Universal Precise™ is the next generation in core & coil technology, featuring a smaller, lightweight design and improved temperature performance. Universal Precise™ fits virtually all
applications, and has no exposed live metal parts. There are no plastic extrusions, which prevents
breakage during shipping. Color-coded leads make installation easy.
50 Hertz
Universal offers 50 Hz core & coil ballasts to meet the rapid growth in demand in international
markets. Our ballasts are available for 220, 230, and 240 volt electrical systems.
F-Can
These ballasts are used primarily for indoor downlighting applications where quiet operation is essential. All
the components of these ballasts are enclosed in a fluorescent-style ballast can and are thermally
protected.
HID
F-Can Ballasts
Core and Coil Ballasts
PAGE 5-3
HID Ballast Kits
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Product Overview
For maximum safety and reliability, all Universal capacitors come with built-in bleed resistors (patented
by Universal) and approved by CSA (CSA file #LR51331, metal cases only). Environmental safety is
assured by use of biodegradable, nontoxic (no PCBs) dielectric fluid (soybean oil), patented by Universal
for use in capacitors. Dry-film capacitors do not include protective devices. Since they can fail in a hazardous manner, it is the responsibility of the purchaser to take appropriate precautions.
Capacitors
Universal has a comprehensive line of capacitors in metal cases (up to 525V ratings) and plastic cases
(up to 400V ratings). All Universal capacitors are designed for 60,000 hours of continuous life. They’re
exceptionally reliable because we put them through accelerated life testing at 125% rated voltage and
rated temperature +10°C.
Universal capacitors are normally packaged with ballasts. They may also be ordered separately, bulk
packaged, or individually boxed with the suffix “BH” (metal cases only). Capacitor weights vary from
1/4 lb. to 1 lb. each.
Dry Capacitors
Type “P” plastic case capacitors described in this section are dry and do NOT contain safety
interrupters (or oil). Plastic cases are UL rated “94V-O” (for use up to 100°C maximum). Type “P”
capacitors are supplied with stranded copper wire leads 8 inches long (18 awg, with 150°C rated insulation). Capacitor rolls are sealed inside plastic cases using epoxy. Design and testing of Universal
capacitors follow specifications in Electronic Industries Association (EIA) Standard 456-A, titled
“Metalized Film Dielectric Capacitors for Alternating Current Application.”
“P” capacitors are designed and rated for continuous duty AC voltages below 400VAC @ 50 or 60 Hz.
Capacitors used with HID ballasts at voltages above 400VAC should contain interrupters (available from
Universal in oval “MF” and round “RMF” oil-filled metal cases).
Metal and Oil Filled Capacitors
HID
Plastic Dry Type Capacitors
Protective Device (Only in metal cases)
Protective device to prevent case rupture
Normal Cover Position
Normal Cover Position
1/2"
1/2"
Barrier
Normal Position of Protective Device
Barrier
Barrier
Position of Protective Device
After Activation
Capacitor Protective
CapacitorDevices
Protective Devices
PAGE 5-4
Barrier
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Oil-Filled Capacitors
µF
VACr
5.0
300
6.0
Part #
Case
Ht (“)
µF
VACr
Part #
Case
Ht (“)
005-1466-BH 1.25 oval
2.2
24.0
480
005-2779-BH 1.75 oval
3.9
300
005-1561-BH 1.25 oval
2.2
24.5
300
005-3278-BH 1.75 oval
2.7
7.0
300
005-1410-BH 1.25 oval
2.2
26.0
330
005-2669-BH 1.75 oval
3.1
8.0
330
005-1411-BH 1.25 oval
2.2
26.0
525
0052776-BH
1.75 oval
4.3
10.0
330
005-1413-BH 1.25 oval
2.7
28.0
240
005-1886-BH
1.75 dia
2.3
10.0
400
005-2666-BH 1.25 oval
3.9
28.0
300
005-1468-BH 1.75 oval
3.1
10.0
400
005-1184-BH 1.50 oval
2.7
28.0
425
005-1799-BH 1.75 oval
3.9
10.0
400
005-2167-BH
1.75 dia
2.9
30.0
440
005-1475-BH 1.75 oval
3.9
12.0
300
005-1467-BH 1.25 oval
3.1
32.0
300
005-2351-BH 1.75 oval
3.1
12.0
400
005-2799-BH 1.50 oval
2.7
32.0
525
005-1474-BH 2.00 oval
3.9
12.0
440
005-1464-BH 1.50 oval
3.1
33.0
300
005-1470-BH 1.75 oval
3.1
13.0
300
005-1414-BH 1.25 oval
3.1
35.0
330
005-1421-BH 1.75 oval
3.1
14.0
240
005-1884-BH
1.75 dia
2.3
36.0
525
005-2793-BH 2.00 oval
4.3
14.0
300
005-1415-BH 1.50 oval
2.7
40.0
240
005-1887-BH
1.75 dia
2.7
15.0
400
005-1185-BH 1.75 oval
2.7
40.0
300
005-1768-BH 1.75 oval
3.9
16.0
300
005-1498-BH 1.50 oval
2.7
48.0
330
005-1422-BH 1.75 oval
3.9
17.5
300
005-1417-BH 1.50 oval
3.1
52.0
240
005-1888-BH
2.00 dia
2.9
18.0
440
005-1401-BH 1.75 oval
3.1
55.0
240
005-1594-BH 1.75 oval
3.5
18.5
330
005-1796-BH 1.50 oval
3.1
55.0
300
005-2117-BH 1.75 oval
3.9
20.0
240
005-1885-BH
1.75 dia
2.3
20.0
330
005-1418-BH 1.50 oval
3.1
20.5
400
005-3262-BH 1.75 oval
3.1
21.0
525
005-1495-BH 1.75 oval
3.9
22.5
300
005-1419-BH 1.50 oval
3.5
24.0
360
005-3160-BH 1.75 oval
3.1
24.0
400
005-2664-BH 1.75 oval
3.1
HID
PAGE 5-5
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
Notes
PAGE 5-2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Dry Capacitors
--
µF V
100°C Rated
Part #
DIA (“) L (“)
105°C Rated
Part #
DIA (“) L (“)
280
005-4400-BH 1.18 2.20 R17058511-BH 1.26 2.36
280
005-4051-BH 1.18 2.76 R17058512-BH 1.26 2.83
330
R17058539-BH 1.26 2.24
280
R17058513-BH 1.26 2.36
280
005-4052-BH 1.18 2.76 R17058514-BH 1.26 2.83
280
005-4053-BH 1.58 2.76 R17058515-BH 1.65 2.83
300
005-4054-BH 1.58 2.76 R17058535-BH 1.65 2.83
330
R17058541-BH 1.65 2.83
280
005-4407-BH 1.18 2.76 R17058517-BH 1.26 2.83
280
005-4056-BH 1.58 2.76 R17058519-BH 1.65 2.83 R17058226-BH 1.65
330
005-4408-BH 1.58 2.76 R17058578-BH 1.65 2.83 R17058227-BH 1.65
400
005-4409-BH 1.58 2.76 R17058555-BH 1.65 2.83
400
005-4025-BH 1.58 3.74 R17058557-BH 1.65 3.82 R17058310-BH 1.65
400
005-4485-BH 1.58 2.76 R17058558-BH 1.65 2.83
300
005-4099-BH 1.58 2.76 R17058536-BH 1.65 2.83
330
005-4411-BH 1.58 2.76 R17058543-BH 1.65 2.83
400
005-4412-BH 1.58 3.74 R17058580-BH 1.65 3.82
330
005-4044-BH 1.58 3.74
170
R17058500-BH 1.26 2.83
280
005-4060-BH 1.58 2.76 R17058520-BH 1.65 2.83
280
005-4416-BH 1.58 2.76 R17058520-BH 1.65 2.83 R17058232-BH 1.65
400
005-4164-BH 1.58 3.74 R17058560-BH 1.65 3.82
400
R17058562-BH 1.65 3.82
400
005-4026-BH 1.77 3.74 R17058563-BH 1.85 3.82 R17058320-BH 1.85
280
005-4062-BH 1.58 2.76 R17058522-BH 1.65 2.83
280
005-4420-BH 1.58 2.76 R17058522-BH 1.65 2.83
330
R17058547-BH 1.65 2.83
400
R17058588-BH 1.65 3.82
280
R17058523-BH 1.65 3.82
170
005-4065-BH 1.58 2.76 R17058501-BH 1.65 2.83
280
005-4066-BH 1.58 3.74 R17058526-BH 1.65 3.82
330
400
R17058564-BH 1.85 3.82
400
005-4432-BH 1.77 3.74 R17058565-BH 1.85 3.82
400
005-4128-BH 1.77 3.74 R17058567-BH 1.85 3.82
400
005-4483-BH 1.77 3.74 R17058569-BH 1.85 3.82
280
R17058527-BH 1.65 3.15
280
R17058528-BH 1.65 3.82
280
R17058529-BH 1.65 3.82
400
005-4438-BH 1.85 3.74 R17058571-BH 1.85 3.82 R17058342-BH 1.85
400
005-4027-BH 1.77 4.61
330
005-4047-BH 1.58 4.61 R17058552-BH 1.65 4.76
300
005-4048-BH 1.58 4.61 R17058537-BH 1.65 4.76
400
005-4484-BH 1.77 4.61 R17058574-BH 1.85 4.76
170
005-4071-BH 1.58 2.76 R17058502-BH 1.65 2.83
280
005-4072-BH 1.58 4.61 R17058530-BH 1.65 4.76
330
005-4447-BH 1.77 3.74 8R17058553-BH 1.85 3.82
2.83
2.83
3.82
2.83
3.82
5.31
FOR MORE INFORMATION CALL
PAGE 5-7
1-800-BALLAST
(225-5278)
HID
5.0
5.0
5.0
6.0
6.0
7.0
8.0
8.0
10.0
10.0
10.0
10.0
10.0
11.0
12.0
12.0
12.0
13.0
14.0
14.0
14.0
14.0
15.0
15.0
16.0
16.0
16.0
17.0
17.5
20.0
20.0
20.0
20.0
20.5
21.0
22.0
22.5
22.5
24.0
24.0
24.0
24.5
26.0
26.5
28.0
28.0
28.0
90°C Rated
Part #
DIA (“) L (“)
Dry Capacitors (Cont.)
µF V
35.0
35.0
40.0
40.0
48.0
48.0
52.0
52.0
55.0
55.0
55.0
90°C Rated
Part #
DIA (“) L (“)
100°C Rated
Part #
DIA (“) L (“)
280
280
005-4075-P
1.77 4.61
240
005-4456-P
1.58 3.74
240
005-4077-P
1.58 4.61
280
330
170
005-4087-P
1.77 3.74
280
005-4127-P
1.77 4.61
240
005-4465-P
1.77 3.74
240
005-4084-P
1.77 4.61
300
R17058531-BH 1.65
R17058532-BH 1.85
R17058505-BH 1.65
R17058506-BH 1.65
R17058533-BH 1.85
R17058554-BH 2.05
R17058503-BH 1.85
R17058534-BH 1.85
R17058507-BH 1.85
R17058509-BH 1.85
R17058538-BH 1.85
105°C Rated
Part #
DIA (“) L (“)
3.82
4.76
3.82
4.76
4.76
4.76
3.82
4.76
3.82 R17058212-BH 1.85
4.76
4.76
5.31
HT HID Ballasts
Designed for high temperature applications
Includes 105º Capacitors and Ignitors
Voltage
Catalog Number
Carton Pack
Metal Halide
175W Quad-Tap M175MLTAC3M 818C
HID
Lamp Wattage
175W Multi-5 M175ML5AC3M 818C
175W
480V M17548TAC3M 818C
175W Tri-Tap M175TRIAC30 818C
250W Quad-Tap M250MLTAC3M 818C
250W Quad-Tap M250MLTAC4M 818C
250W Multi-5 M250ML5AC3M 818C
250W Multi-5 M250ML5AC4M
250W
480V M25048TAC3M 818C
250W
480V M25048TAC4M 818C
400W Quad-Tap M400MLTAC4M 818C
400W Multi-5 M400ML5AC4M 818C
400W
480V M40048TAC4M 818C
400W Tri-Tap M400TRIAC4M 818C
Lamp Wattage Voltage
Catalog Number
Carton Pack
Pulse Start Metal Halide
175W Quad-Tap P175MLTAC3M 818C
Kit
818K
175W Multi-5 P175ML5AC3M
400W Quad-Tap P400MLTAC4M 818C
400W Multi-5 P400ML5AC4M
818K
818K
High Pressure Sodium
818K
818K
818K
Refer to catalog pages for ballast dimensions and electrical data
Quad-Tap: 120/208/240/277 Volt
Multi-5: 120/208/240/277/480 Volt
Tri-Trap: 120/277/347
480V include 120V tap for stand-by lighting
Kit
100W Quad-Tap S100MLTLC3M 818C
100W
480V S10048TLC3M 818C
150W Quad-Tap S150MLTLC3M 818C
150W
480V S15048TLC3M 818C
150W Tri-Trap S150TRILC3M 818C
250W Multi-5 S250ML5AC4M
400W Quad-Tap S400MLTAC4M 818C
400W Multi-5 S400ML5AC4M 818C
400W Multi-5 S400ML5AC5M
400W
480V S40048TAC4M 818C
818K
818K
818K
818K
818K
FOR MORE INFORMATION CALL
PAGE 5-8
1-800-BALLAST
(225-5278)
5.75"
Slot
aces
7.75"
2.75"
Bracket Reference Chart
.281 Slot
6 Req.
1.75"
on center
7.75"
Bracket B4
0.50"
TYP.
CORE & COIL
WELDED
BRACKETS
CORE & COIL
ADJUSTABLE
MOUNTING
Bracket B4 B R A C K E T S
6.10"
on center
0.55"
6.75"
0.50"
5.75"
on center
.640"
7.75"
7.75"
BracketAll welded
B3brackets are .093” thick.
Ref. Drawing B2
Ref. Drawing B1
0.2
3
Routinely supplied with replacement kits.
0.75"0.25" .250 Slot
2 Places
0.75"0.25"
Ref. Drawing ADJ1
.250 Slot
2 Places
1.25" 1.00"
0.75"0.25"
0.75"0.25"
3.35"
0.75"0.25"
1.25" 1.00"
0.30"
3.35"
4.00"
30"
3.35"
5.25"
0.30"
Bracket B2
Bracket B1-A
.281 Slot
6 Req.
.281 Slot
2 Places
0.75"0.25"
.250 Slot
2 Places
1.25"
2.65"
6.75"
3.35"
Bracket B1
on center
4.00"
7.75"
0.55"
0.30"
4.60"
.640"0.50"
7.75"
BracketB1-A
B4
Bracket
Bracket B3
Ref. Drawing B4
2.75"
R. TYP.
.281 Slot
6 Req.
0.70"
2.65" 6.10"
4.60" on
center
5.25"
0.25" Dia.
3 Holes
0.50"
R. TYP.
6.10"
on center
0.55"
.640"
Bracket
B2 B4
Bracket
.281 Slot
6 Req.
0.50"
TYP.
7.75"
R. TYP.
0.50"
45º
2.65"
0.58"
.29"
1.50"
0.90"
0.70"
6.10"
0.25" Dia.
2 0.55"
Holes
6.75"
on center
1.50"
For use with:
7.75"
6.10"
0.50"
Bracket B3
Bracket
B1-B
Bracket
B4
Bracket B4
.640"
7.75"
OR
.640"
0.25" Dia.
3 Holes
• 50 to 175 watt Mercury, High Pressure
Sodium and
Metal Halide and some 250 watt Metal Halide
on center
0.55"
0.93"
0.70"
0.70"
on center
0.70"
7.75"
4.60"
6.75"
on center
5.25"
3 Holes
0.29"
R. TYP.
on center
0.25" Dia.
1.30"
1.75"
0.93"
0.50"
1.00"
1.75"
2.75"0.25"
0.09"
0.43"
7.75"
1.25"
1.50"
Bracket
B2 B4
Bracket
5.50"
6.75"
on center
1.81"
2.65"
on center
7.75"
on center
.281 Slot
6 Req.
0.70"
5.25" 6.75"
Ref. Drawing MB1
1.75"
TYP.
.281 Slot
6 Req.
1.75"
on center
TYP.
Bracket B1-A
Bracket B3
4.00"
7.75"
7.75"
Ref. Drawing B1-B
1.50"
0.30"
7.75"
TYP.
on center
1.25" 1.00"
2.75"
0.50"
3.35"
0.50"
Bracket B2
2 Places
0.70"
on center
6.10"
.281 Slot
2 Places
Ref. Drawing ADJ2.250 Slot
OR
1.25" 1.00"
0.70"
2.75" 1.75"
0.30"
R. TYP.
4.00"
0.50"
Bracket B1-A
5.25"
Ref. Drawing B3
0.75"0.25"
0.50"
TYP.
1.25"
4.60"
0.30"
4.00"
Bracket B1-A
Bracket B1
.281 Slot
2.75" 1.75" 2 Places
on center
0.75"0.25"
3.35"
3.35"
Bracket B1
4.00"
Ref. Drawing B1-A
0.30"
OR
4.00"
4.60"
0.30"
4.00"3.35"
0.30"
0.70"
R. TYP.
Bracket B3
0.70
2.65"
0.25" Dia.
3 Holes
OR
Ref. Drawing MB2
OR
7.25"
1.880"
.090"
.460"
1.300"
2.685"
1.750"
45ϒ
.290"
.930"
.580"
.290"
.735"
1/4"
OR
Dia.
2 Holes
For use with:
• 250 to 1500 watt Metal Halide
• 250 to 1000 watt High Pressure Sodium and
Mercury Vapor
OR
PAGE 5-9
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
.835"
Application And Operating Information
Underwriters’ Laboratories, Inc. Acceptance
All F-Can and Weatherproof ballasts listed in this
catalog are Underwriters’ Laboratories, Inc. white card
listed, except those for 347 volt operation. All Core &
Coil and Potted Core & Coil ballasts listed in this catalog are Underwriters’ Laboratories, Inc.
yellow card listed (component recognized).
temperature. The ballast will continue to cycle until
the cause of overheating is eliminated. If the ballast is
defective, it must be replaced. If the cause is external,
the ballast will resume normal operation after
abnormal conditions are eliminated.
To attain normal ballast life, the maximum coil
temperature of the ballast should not exceed the
rating of the insulation system. A temperature increase
of 10° C results in a 50% reduction of ballast life.
Ballast Replacement
Ballast replacement presents the possibility of
exposure to potentially hazardous voltages and should
be performed only by qualified personnel. All installation, inspection and maintenance should be performed
only with the entire circuit power to fixture or equipment turned off. Installation shall be in accordance
with National Electric Code.
Low Ambient Temperature (cold)
As temperatures drop, less and less vaporized gas is
available within the arc tube of a high intensity
discharge lamp, thereby causing an increase in the open
circuit voltage required to initiate an arc in the lamp,
until a point is reached where the lamp cannot be started. The minimum temperature at which any ballast listed
in this catalog will provide reliable starting is
listed with the electrical characteristics.
Heat
A ballast, like any other electrical device, generates
heat during normal operation. Planning for maximum
heat dissipation with proper fixture design, installation planning and ballast selection will minimize the
possibility of a heat-related problem arising. Excessive
temperature will have an adverse effect on ballast life.
Normal temperature limits:
F-Can Ballasts
Maximum case temperature: 90°C
Potted Core & Coil Ballasts and
Core & Coil Ballasts
Insulation: Class 180°C
Maximum coil temperature: 165°C
(measured by change of resistance method)
Ballasts should be protected from weather, moisture, or
other abnormal atmospheric conditions, unless specifically designed for use under adverse conditions.
Fusing
The purpose of fusing an HID ballast is to remove the ballast from the power line in the event of a ballast system
failure. A fuse does not protect the ballast from failing.
Because the temperature in the ballast compartment is
high, typically 90OC, fuse ratings are specified at 25OC, and
that this rating declines as the temperature increases, HID
fuse recommendations are made between 2 and 3 times
the maximum current the ballast will draw during all normal conditions.
HID
All F-Can ballasts listed in this catalog are equipped
with built-in automatic resetting internal thermal
protection as a standard feature.
Fast-blow fuses should not be used due to the possibility
of high inrush currents. These currents are due to the
fact that the power can be applied ant any point in the AC
voltage waveform. Standard and slow-blow are acceptable.
Whenever a ballast with thermal protection is used, it
is imperative that the fixture/ballast/lamp combination
be heat tested under actual or simulated installation
conditions to assure that the ballast will not cycle.
The resetting thermal protector functions as a
thermostat which will open and temporarily
deactivate the ballast when it exceeds the permissible
When using the 120V tap for auxiliary lighting, a slowblow fuse should be used to protect the ballast from damage from a fault in the auxiliary lighting circuit.
REMOTE MOUNTING DISTANCE
Maximum Length in Feet for Remote Mounting of HID Ballasts to Lamp
ANSI
Lamp Type
Watts
12 GA
14 GA
16 GA
18 GA
M57
M58
M59
M47
M48
Metal Halide
Metal Halide
Metal Halide
Metal Halide
Metal Halide
175
250
400
1000
1500
272
194
132
196
146
171
122
83
123
92
107
77
52
77
58
67
48
33
48
36
For proper installation, insure that remote ballasts are properly vented and mounted to a heat-dissipating surface.
PAGE 5-10
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
Sound
High intensity discharge lamp ballasts, like all electromagnetic devices, produce noise, or “hum.” It is the
degree of noise which determines the existence of a
problem. Ballast noise will only be noticeable when it
exceeds the ambient sound level of the installation. It
is obvious that a ballast designed primarily for
outdoor or factory use would not be suitable in an
office environment.
The vast improvements in all high intensity discharge
lamps and ballasts, and their excellent energy
efficiency, have made them viable options for many
indoor applications. The ballasts being considered
should be carefully analyzed to insure that there will
not be an objectionable level of ballast noise.
All F-Can ballasts listed in this catalog are “Sound
Rated” to aid in the selection of a ballast which is
proper for the environment in which it will operate.
Potted Core & Coil ballasts are also designed to
operate at reduced sound levels, generally several
decibels lower than a standard Core & Coil ballast.
Core & Coil ballasts are not sound rated.
In situations where light output necessitates using a
ballast with a sound rating or noise level not normally
acceptable, the ballast should be remotely mounted.
Note, however, that not all ballasts listed in this
catalog are designed or recommended for remote
mounting.
Polarity
Polarity refers to the proper connection of ballast lead
wires to line wires. To aid you in making a
correct installation, Universal ballast leads are
color-coded for easy identification. The white or
yellow ballast lead is to be connected to the neutral or
common. Choose the appropriate ballast voltage lead
to connect to the line.
Operating Line Voltage Limits
To receive the full benefits of rated lamp output and
to prolong ballast life, it is essential that the voltage
supplied to an installation be maintained within the
prescribed limits.
In general, the line voltage supplied to a lag type
ballast (reactor or high reactance autotransformer)
should be maintained within 5% of the voltage for
which the ballast is rated. The line voltage to lead type
ballasts (constant wattage autotransformer or constant
wattage isolated) should be maintained within 10%.
Subjecting a ballast to excessive voltage for an
extended period of time results in the deterioration
of the coil insulation. This insulation breakdown will
cause early ballast failure.
Low voltage has no damaging effect on the ballast. It
could, however, have an adverse effect on lamp
performance and starting dependability.
Maintenance
Selecting and installing an adequate and efficient
lighting system means nothing if it is not properly
maintained. Maintenance must always be considered
as part of the life cycle cost of any high intensity
discharge lighting installation in order to assure the
continued performance of the system as originally
specified.
First and foremost in importance is proper lamp maintenance. High intensity discharge lamps do not “burn
out” like an incandescent bulb, but rather, undergo
changes within the arc tube which prevent the lamp
from starting properly, warming up and
producing full light output. The beginning of
difficulties such as these generally indicates the end
of a lamp’s useful life. Also, a dead lamp left in a
fixture can be very damaging to the ignitor in
systems which utilize them. To overcome this
problem, Universal offers automatic shutoff
ignitors, which are described in the ignitor section of
this catalog.
PAGE 5-11
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
Grounding
Ballasts and capacitors or starters in metallic casings
must always be grounded. Ballasts and components
may be grounded to the fixture or otherwise
connected to ground. It would be hazardous to make
contact with an ungrounded fixture, ballast or other
electrical component while in operation.
Application And Operating Information
In difficult locations, group replacement of all the
lamps, working or not, is often more economical
and convenient than spot replacement. The same,
of course, applies to ballasts which might be
approaching the end of their life. Only you can decide
what is right for your lighting system, but what is
important is that you have a maintenance program.
Periodic cleaning of the fixtures’ lenses and reflectors
is also important in maintaining proper light output.
For indoor systems, maintenance of reflective
surfaces, such as walls and ceilings, will also help
assure proper levels of illumination.
STANDBY LIGHTING AND PACKAGING
Standby Lighting
To provide light during a high intensity discharge
lamp’s warmup period, or the cool-down period
following a power interruption which has
extinguished it, incandescent standby lighting can be
incorporated. This is accomplished by use of a
standby lighting device, or remote, that switches off
an incandescent lamp incorporated into the fixture
once an arc has been established, or reestablished, in
the HID lamp. Generally, standby lighting devices operate on 120 volts, so a tap must be provided on ballasts
designed to operate at higher line voltages.
HID
The 120 volt terminal or lead on all Universal dual-,
tri-, quad- and multi-volt ballasts can be used as a tap
for standby lighting when the ballast is utilized for any
of the higher voltages. Many single voltage
ballasts are available with a 120 volt tap and are
listed throughout the Core & Coil data section. Other
single voltage ballasts may be available in this
version. Consult our Customer Service Department
for availability and price information.
Any connection to the 120 volt tap must be
accomplished by means of a slow-blow fuse. This fuse
will protect the ballast from abnormal conditions in
the standby lamp circuit or its control device. The fuse
should be located in the coolest place in the
fixture (below 80°C). The recommended fuse
amperage and maximum auxiliary lamp wattage
are listed in this catalog for each ballast suitable for
standby lighting applications.
Be sure to follow the wiring instructions of the
standby lighting device manufacturer. All applicable
requirements of the National Electrical Code must be
met.
Packaging
Standard Pack
Universal’s high intensity discharge lamp ballasts are
routinely packed in easy-to-handle cartons
containing from 1 to 20 units per carton, depending on
the size and weight of the ballasts. Consult Customer
Service for the number of “units per carton” for shipment with attached mounting brackets, capacitors
(for high power factor units), and ignitors (if required).
Other ordering criteria may cause
packaging to vary.
Tray Pack
For the convenience of large quantity users who
request it, Universal ballasts may be packed in trays.
The number of units depends upon the size and weight
of each ballast. These trays are large
corrugated cartons with lids and sides that come off
easily. This type of packaging affords Universal
customers a savings of time and money on their own
production costs. There are fewer cartons to open,
break up and dispose of on the assembly line;
warehouse handling is reduced and inventory control
is easier. There is no additional charge for tray
packing.
Individual Cartons
All Distributor Replacement Kits, Weatherproof, Potted
Core & Coil and other larger ballasts are
packaged in individual cartons.
Individual cartons serve a threefold purpose: as a
display carton, a stock package, and a shipping
container for the retail market. Individual cartons may
be packed in master cartons, depending on weight
and size.
Individual carton packaging may be available for other
ballasts. Contact our Customer Service Department
for availability and cost.
PAGE 5-12
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Nomenclature
UNIVERSAL PRECISE™
ABBREVIATIONS
UL Bench Top Rise Temperature Code
CWA
Constant Wattage Autotransformer
CWI
Constant Wattage Isolated
ISO
Regulated Lag
R-HPF
Reactor—High Power Factor
R-NPF
Reactor—Normal Power Factor
To facilitate UL inspection, the UL Bench Top Rise
Temperature Code is shown on the Universal Core &
Coil Ballast label as 1029X. 1029 is the UL Standard
for HID Ballasts, and the X is the
temperature code. If a fixture is UL listed for 1029D,
then automatically all ballasts with an A, B, C or D
temperature classification are acceptable for use
within that same fixture.
HX-HPF Lag Type — High Reactance
Autotransformer—High Power Factor
UL Bench Top Rise Letter Code
Temperature Range for
Class H (180° C) Ballasts
HX-NPF Lag Type — High Reactance
Autotransformer—Normal Power Factor
A<75°C
B 75°C < 80°C C 80°C < 85°C
D 85°C < 90°C E 90°C < 95°C F 95°C < 100°C
Field
1
2
3
4
5
6
7
8
9
1
5
1
M
3
0
1
C
Number of Digits
1
C
0
0
Container Type
(C/T/I/K)
Pack Code
(000 TO 999)
Field
1
A
Socket Type & Other
Oddities (M/D/X/L)
Frame Size
(E/3/4/5/X)
Style
(C/F/W/E/I/P)
Circuit Type
(R/A/I/O/L/M)
3
M L T
Primary
Voltage
(MLT/ML5/TRI/
48T/120/277/
230)
Lamp Type
(M/P/S/H)
2 to 4
2 0 0 0
Wattage
1
M
Description
(M) Metal Halide, (P) Pulse Start Metal Halide, (S) High Pressure Sodium
2
35 to 2000 Watts (Varies from two to four digits)
3
(MLT) Quad, (ML5) Multi-5, (TRI) TriVolt, (48T) 480/120, (120) 120, (277) 277, (230) 230V/50Hz
4
(R) Reactor, (A) CWA, (I) CWI, (O) IsoReg, (L) High Reactance/Lag, (M) MagLag
5
(C), C&C, (F) F-Can, (W) Weatherproof, (E) Encased/Potted C&C (I) Indoor Encased
6
(E) E&I, (3) 3x4, (4) 4-3/4, (5) 5-3/4, (X) Non Core and Coil
7
(M) Mogul or Medium, (D) Double Ended, (X) Multiple Lamps, (L) Low Loss
8
Pack Code (000 to 999, per pack code listing)
9
(C) Carton, (T) Tray, (I) Individual, (K) Kit
PAGE 5-13
HID
1
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Specifications
TYPICAL SPECIFICATIONS
FOR HID BALLASTS
1. Ballasts shall be designed in accordance with all applicable ANSI specifications including ANSI C82.4.
2 . The Core & Coil ballast shall be designed with class “H” (180°C) or higher insulation system and vacuum
impregnated with a 100% solid based resin.
3 . All coils shall be precision wound.
4 . Core & Coil ballasts shall be designed to operate at least 180 cycles of 12 hours on and 12 hours off, with
the lamp circuit in an open or short-circuited condition and without undue reduction in ballast life.
5. Core & Coil ballast and starter combinations shall be designed to provide a reliable lamp starting down to
-40°C for High Pressure Sodium and Pulse Start Metal Halide and -30°C for Metal Halide and Mercury at
minimum rated line voltage.
6. Manufacturer shall provide written warranty against defects in workmanship, including replacement, for two
years from date of manufacture.
CAPACITORS
1. All capacitors will be provided with a self-contained internal bleeder resistor.
HID
2. All oil-filled capacitors will be housed in corrosion-resistant steel cans and contain .25” quick disconnect
terminals.
3. All capacitors will be supplied by ballast manufacturer.
IGNITORS
1. All ignitors will be epoxy-filled with either a plastic or aluminum external housing.
2. The ignitor shall be so designed to provide six months of lamp open circuit operation without failure.
KITS
1. All HID kits shall be precision wound to insure proper insulation.
2. All HID kits shall be pre-wired.
3. All HID kits shall be built with color-coded leads.
4. All HID kits are to be UL and CSA recognized following the guidelines found in UL 1029 and
CAN/CSA-22.2 No. 74-92 (part 2 and 3).
5. Universal Model __________________________ (or approved equal).
PAGE 5-14
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Distributor Replacement Kits
Universal’s HID distributor replacement kits contain the appropriate core & coil, a properly rated capacitor, and all
other components required for ballast replacement. Our kits are the quickest and easiest to install of any on the
market, thanks to unique design features like:
•
•
•
•
•
Prewired capacitor and ignitor (if required) to save installation time and reduce wiring errors.
Color-coded leads to reduce risk of incorrect wiring inside the fixture.
Features that exceed UL standards, including capacitors that offer trip fault protection.
Simple installation instructions and troubleshooting tips.
UPS shippable box.
Our kit offerings include many quad voltage (120, 208, 240, or 277 volt) and 480 volt core & coil ballasts, as well as
the new Multi-5 five-voltage ballast. 480 volt ballasts are equipped with a 120 volt tap to accommodate stand by
lighting.
Also available for Metal Halide and High Pressure Sodium applications, Universal Lighting’s Multi-5TM Ballast-Lamp
Replacement Kit. This easy to carry convenient all-in-one kit ensures ballast lamp compatibility.
Distributor replacement kit cartons are packaged in master cartons in quantities from 1 to 6 units. Master carton
quantities can be found on Universal’s list and distributor price sheets.
Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits
LampType
Wattage
Voltage
Frame Size
Old Part Number
175
120/208/240/277
3 x 4
1130-91R-500K
M175MLTAC3M500K
175
Multi-5™ Uni-Pak™
3 x 4
New
M175ML5AC3M555K
250
120/208/240/277
250
Multi-5™ Uni-Pak™
250
120/208/240/277
175
175
Metal
Halide
250
250
250
250
250
400
400
400
400
400
1000
1000
1000
1000
3 x 4
480-120
3 x 4
1130-31-500K
3 x 4
New
Multi-5
480-120
Multi-5
1130-92-500K
3 x 4
New
3 x 4
4.25 x 4.75
4.25 x 4.75
1130-32-500K
1130-92R-500K
New
M175ML5AC3M500K
M17548TAC3M500K
M250MLTAC3M500K
M250ML5AC3M500K
M250ML5AC3M555K
M25048TAC3M500K
M250MLTAC4M500K
M250ML5AC4M500K
New
M250ML5AC4M555K
4.25 x 4.75
1130-93U-500K
M400MLTAC4M500K
Multi-5
4.25 x 4.75
1130-826S-500K
480-120
4.25 x 4.75
1130-33R-500K
120/208/240/277
4.25 x 5.75
1130-97R-500K
480-120
120/208/240/277
120/208/240/277
4.25 x 4.75
4.25 x 4.75
Multi-5™ Uni-Pak™ 4.25 x 4.75
120/208/240/277
Multi-5
4.25 x 5.75
4.25 x 5.75
Multi-5™ Uni-Pak™ 4.25 x 5.75
480-120
1250
120/208/240/277
1500
480-120
1500
3 x 4
Multi-5™ Uni-Pak™ 4.25 x 4.75
New
120/208/240/277
4.25 x 5.75
4.25 x 5.75
4.25 x 5.75
4.25 x 5.75
1130-32R-500K
1130-93R-500K
New
1130-97-500K
New
New
1130-57-500K
New
1130-99R-500K
1130-69R-500K
PAGE 5-15
M25048TAC4M500K
M400MLTAC4M500K
M400ML5AC4M500K
M400ML5AC4M555K
M40048TAC4M500K
M1000MLTAC5M500K
M1000MLTAC5M500K
M1000ML5AC5M500K
M1000ML5AC5M555K
M100048TAC5M500K
M1250MLTAC5M500K
M1500MLTAC5M500K
M150048TAC5M500K
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
1000
Multi-5
New Part Number
Distributor Replacement Kits
Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits
LampType
Wattage
Voltage
Frame Size
35
120/208/240/277
3 x 4
70
120/208/240/277
3 x 4
70
100
120/208/240/277
100
Pulse Start
480-120
120/208/240/277
100
120/208/240/277
70
150
150
150
120/208/240/277
480-120
120/208/240/277
120/208/240/277
480-120
175
120/208/240/277
175
Multi-5
175
175
175
200
120/208/240/277
120/208/240/277
480-120
Multi-5
480-120
480-120
350
120/208/240/277
350
Multi-5
320
320
350
350
3 x 4
New
400
480-120
400
450
450
450
Multi-5
120/208/240/277
Multi-5
480-120
750
120/208/240/277
750
480-120
750
Multi-5
875
120/208/240/277
1000
Multi-5
1000
120/208/240/277
New
3 x 4
New
3 x 4
New
4.25 x 5.75
New
4.25 x 5.75
New
3 x 4
New
New
4.25 x 4.75
4.25 x 4.75
New
New
New
4.25 x 4.75
1130-827-500K
4.25 x 4.75
New
4.25 x 4.75
1130-622-500K
4.25 x 4.75
New
4.25 x 4.75
480-120
New
3 x 4
480-120
120/208/240/277
New
11310-543-500K
3 x 4
4.25 x 4.75
400
New
3 x 4
Multi-5
Multi-5
M70MLTLC3M500K
New
New
4.25 x 4.75
250
11310-510-500K
3 x 4
Multi-5
Multi-5
M35MLTLC3M500K
11310-90-500K
3 x 4
4.25 x 4.75
4.25 x 4.75
New
New
4.25 x 5.75
4.25 x 5.75
4.25 x 5.75
4.25 x 5.75
4.25 x 5.75
4.25 x 5.75
PAGE 5-16
M100MLTLC3M500K
M100MLTLC3D500K
M10048TLC3M500K
M150MLTLC3M500K
M150MLTLC3D500K
M15048TLC3M500K
P175MLTAC3M500K
P175MLTAC3L500K
P175ML5AC3M500K
P175MLTAC4L500K
P17548TAC4L500K
P200ML5AC3M500K
P250MLTAC4L500K
P250ML5AC4M500K
P250ML5AC4L500K
P25048TAC4L500K
P320MLTAC4O500K
P32048TAC4L500K
4.25 x 4.75
4.25 x 4.75
M70MLTLC3D500K
New
1130-829-500K
4.25 x 4.75
M7048TLC3M500K
P320ML5AC4M500K
New
4.25 x 4.75
M50MLTLC3M500K
New
4.25 x 4.75
4.25 x 4.75
New Part Number
New
11310-95-500K
3 x 4
250
250
320
3 x 4
4.25 x 4.75
3 x 4
120/208/240/277
120/208/240/277
3 x 4
250
320
Metal Halide
HID
50
Old Part Number
New
New
New
New
New
New
New
New
New
New
P32048TAC4M500K
P350MLTAC4M500K
P350ML5AC4M500K
P350ML5AC4L500K
P35048TAC4L500K
P400MLTAC4L500K
P400ML5AC4M500K
P40048TAC4M500K
P450MLTAC4M500K
P450ML5AC4M500K
P45048TAC4M500K
P750MLTAC5M500K
P750ML5AC5M500K
P75048TAC5M500K
P875MLTAC5M500K
P1000MLTAC5M500K
P1000ML5AC5M500K
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Distributor Replacement Kits
Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits
LampType
Wattage
Voltage
Frame Size
50
120/208/240/277
3 x 4
70
70
120/208/240/277
480-120
Old Part Number
New Part Number
12310-95-500K
S50MLTLC3M500K
3 x 4
12310-148R-500K
S7048TLC3M500K
3 x 4
12310-30R-500K
S10048TLC3M500K
3 x 4
12310-160S-500K
4.25 x 4.75
New
3 x 4
12310-153-500K
100
120/208/240/277
3 x 4
150
120/208/240/277
3 x 4
200
120/208/240/277
4.25 x 4.75
250
Multi-5
4.25 x 4.75
H.P.S.
100
150
200
250
250
250
400
400
400
400
400
400
400
600
1000
1000
1000
1000
480-120
480-120
480-120
120/208/240/277
480-120
12310-90-500K
12310-165-500K
4.25 x 4.75
4.25 x 4.75
Multi-5™ Uni-Pak™ 4.25 x 4.75
Multi-5
4.25 x 4.75
120/208/240/277
4.25 x 4.75
Multi-5
4.25 x 5.75
480-120
4.25 x 5.75
480-120
120/208/240/277
4.25 x 4.75
4.25 x 5.75
Multi-5™ Uni-Pak™ 4.25 x 4.75
120/208/240/277
4.25 x 5.75
Multi-5
4.25 x 5.75
120/208/240/277
4.25 x 5.75
Multi-5™ Uni-Pak™ 4.25 x 5.75
480-120
4.25 x 5.75
New
New
1230-92S-500K
1230-32S-500K
New
New
1230-93U-500K
1230-33U-500K
New
1230-93S-500K
1230-33S-500K
New
New
1230-97S-500K
New
New
1230-57S-500K
S70MLTLC3M500K
S100MLTLC3M500K
S150MLTLC3M500K
S15048TLC3M500K
S200MLTAC4M500K
S20048TAC4M500K
S250ML5AC4M500K
S250MLTAC4M500K
S25048TAC4M500K
S250ML5AC4M555K
S400ML5AC4M500K
S400MLTAC4M500K
S40048TAC4M500K
S400ML5AC5M500K
S400MLTAC5M500K
S40048TAC5M500K
S400ML5AC4M555K
S600MLTAC5M500K
S1000MLTAC5M500K
S1000ML5AC5M500K
S1000ML5AC5M555K
S100048TAC5M500K
HID
PAGE 5-17
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Distributor Replacement Kits
Canadian Tri-Tap Distributor Replacement Kits
LampType
Metal
Halide
Wattage
Voltage
Frame Size
Old Part Number
New Part Number
175
120/277/347
3 x 4
1130-605-502K
M175TRIAC30502K
1130-593R-502K
M250TRIAC4M502K
1130-598-502K
M1000TRIAC5M502K
250
250
4.25 x 4.75
1130-595R-502K
1500
120/277/347
4.25 x 5.75
1130-599-502K
35
50
70
100
175
Pulse Start
Metal Halide
H.P.S.
4.25 x 4.75
New
120/277/347
1000
120/277/347
3 x 4
400
120/277/347
150
120/277/347
120/277/347
120/277/347
120/277/347
120/277/347
120/277/347
120/277/347
200
120/277/347
320
120/277/347
250
350
400
450
750
70
100
150
250
4.25 x 5.75
3 x 4
3 x 4
11310-604-502K
3 x 4
11310-590-502K
3 x 4
3 x 4
120/277/347
4.25 x 4.75
120/277/347
120/277/347
120/277/347
120/277/347
120/277/347
11310-584-502K
New
3 x 4
4.25 x 4.75
120/277/347
New
3 x 4
120/277/347
120/277/347
New
New
New
4.25 x 4.75
New
New
4.25 x 4.75
New
4.25 x 4.75
4.25 x 5.75
New
New
3 x 4
12310-579-502K
3 x 4
12310-588-502K
3 x 4
4.25 x 4.75
12310-584-502K
M50TRILC3M502K
M70TRILC3M502K
M100TRILC3M502K
M150TRILC3M502K
P175TRIAC3M502K
P200TRIAC3M502K
P250TRIAC4M502K
P320TRIAC4M502K
P350TRIAC4M502K
P400TRIAC4M502K
P450TRIAC4M502K
P750TRIAC5M502K
S70TRILC3M502K
S100TRILC3M502K
S150TRILC3M502K
S400TRIAC5M502K
4.25 x 4.75
1230-595U-502K
1000
120/277/347
4.25 x 5.75
1230-598S-502K
S400TRIAC4M502K
S1000TRIAC5M502K
HID
4.25 x 5.75
M35TRILC3M502K
1230-595S-502K
120/277/347
120/277/347
M1500TRIAC5M502K
S250TRIAC4M502K
400
400
M400TRIAC4M502K
1230-593S-502K
M250TRIAC3M502K
PAGE 5-18
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
METAL HALIDE
• 6 0 Hz
• Minimum starting
temperature: -30° C
• Normal and High Power Factor
models available
MH
175-250
WATT
Nom Dimensions
Capacitor
Ignitor
Max Open
Total
Max
UL
Input
Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht
Oval
Ht
(lbs.)
Number to lamp (ft) Top Rise
(1) 175 WATT M57, M107 METAL HALIDE LAMP
120
M175120AC3M
CWA 213 1.90
305
5 17 PC1 2.2
3.6 10 400 1.65
2.83 1.56x2.69 2.69
6.1
n/a
n/a
A
230
M175230AC3M
CWA 205 1.00
310
3 46 PC1 2.25
3.55 12 400 1.65
3.82 1.56x2.69 2.7
6.7
n/a
n/a
C
120 or
2.15
5
M175TRIAC30 CWA 211 0.95
305
17 PC1 2.45
3.8 10 400 1.65
2.83 1.56x2.69 2.69
6.8
n/a
n/a
C
277 or
2
347
0.75
2
120 or
1.90
5
A
208 or M175MLTAC3M CWA 213 1.10
3
C
305
16
PC1
2.2
3.6
10
400
1.65
2.83
1.56x2.69
2.69
6.1
n/a
n/a
240 or
0.95
3
B
277
0.85
2
C
120 or
1.94
5
1.11
3
208 or
240 or M175ML5AC3M CWA 208 1.00
300
3 25 PC1 2.3
3.6 10 400 1.65
2.83 1.56x2.69 2.69
6.8
n/a
n/a
B
277 or
0.83
2
480
0.50
2
480
M17548TAC3M
CWA 210 0.51
315
2 15 PC1 2.0
3.3 10 400 1.65
2.83 1.56x2.69 2.69
5.6
n/a
n/a
D
(1) 250 WATT M58 METAL HALIDE LAMP - 4” Frame
230 M250230AC3M CWA 282 1.40
285
4 46 PC1 3.0
4.3 18 400 n/a
n/a
1.75
3.1
9.0
n/a
n/a
D
120 or
2.78
8
B
277 or M250TRIAC3M CWA 295 1.30
320
3 17 PC1 3.0
4.5 15 400 1.85
3.82 2.01x3.01 2.69
9.0
n/a
n/a
D
347
1.05
3
D
120 or
2.65
8
208 or M250MLTAC3M CWA 297 1.58
5 16 PC1 3.0
315
4.3 15 400 1.85
3.82 2.01x3.01 2.69
9.0
n/a
n/a
D
240 or
1.30
4
277
1.13
3
120 or
2.50
8
1.50
5
208 or
240 or M250ML5AC3M CWA 280 1.25
290
4 25 PC1 3.0
4.3 15 400 1.6
3.82 2.01x3.01 2.69
9.0
n/a
n/a
C
277 or
1.10
3
480
0.65
2
347 M250347AC3M CWA 293 1.05
320
3 42 PC1 3.0
4.5 15 400 1.85
3.82 2.01x3.01 2.69
9.0
n/a
n/a
D
480 M25048TAC3M CWA 292 0.71
320
2 15 PC1 3.0
4.3 15 400 1.85
3.82 2.01x3.01 2.69
9.0
n/a
n/a
D
3
Capacitors are available as an option for high power
factor operation.
See page 5-23 for Reference
Drawings and Wiring Diagrams.
HID
CORE & COIL
PAGE 5-19
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
MH
250-400
WATT
• 6 0 Hz
• Minimum starting
temperature: -30° C
• High Power Factor models
available
• Feature CWA design
HID CORE & COIL BALLASTS
METAL HALIDE
Nom Dimensions
Capacitor
Ignitor
Max Open
Total
Max
UL
Input
Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht
Oval
Ht
(lbs.)
Number to lamp (ft) Top Rise
(1) 250 WATT M58 METAL HALIDE LAMP - 4.75” Frame
120 or
3.05
8
277 or M250TRIAC4M CWA 280 1.25
305
3 17 PC2 1.63
3.63 15 400 1.85
3.82 2.01x3.01 2.69
9.5
n/a
n/a
B
347
1.05
3
120 or
3.05
8
208 or
1.65
5
310
16 PC2 1.53
3.53 15 400 1.85
3.82 2.01x3.01 2.69
9.5
n/a
n/a
B
M250MLTAC4M CWA 290
240 or
1.55
4
277
1.25
3
120 or
2.42
8
208 or
1.40
5
300
4 25 PC2 1.82
3.62 15 360 1.85
3.82 2.01x3.01 2.69 10.8
n/a
n/a
A
240 or M250ML5AC4M CWA 282 1.20
277 or
1.00
3
480
0.60
2
480
M25048TAC4M
CWA 284 0.61
300
2 15 PC2 1.82
3.62 15 360 1.85
3.82 2.01x3.01 2.69 10.8
n/a
n/a
B
(1) 400 WATT M59 METAL HALIDE LAMP
120
M400120AC4M CWA 458 3.94
299
10 28 PC2 2.0
3.86 24 360 1.85
3.82 2.01x3.01 3.12 11.2
n/a
n/a
E
230
M400230AC4M CWA 448 2.20
300
6 46 PC2 2.13
3.75 28 425 n/a
n/a
2.91
3.88 13.0
n/a
n/a
D
277
M400277AC4M CWA 458 1.69
299
5 14 PC2 2.0
3.86 24 360 1.85
3.82 2.01x3.01 3.12 11.2
n/a
n/a
E
120 or
4.22
10
277 or M400TRIAC4M CWA 455 1.67
297
5
17 PC2 2.0
3.9 24 360 1.85
3.82 2.01x3.01 3.12
11.0
n/a
n/a
C
347
1.44
5
120 or
3.90
10
C
277 or M400TRIAC40 CWA 455 1.70
295
5
29 PC2 2.15
3.90 24 360 n/a
n/a 1.91x2.91 3.10
10.5
n/a
n/a
D
347
1.35
4
D
120 or
3.94
10
208 or
2.20
8
M400MLTAC4M CWA 458
299
16 PC2 2.0
3.9 24 360 1.85
3.82 2.01x3.01 3.12
11.2
n/a
n/a
E
240 or
1.93
5
277
1.69
5
120 or
4.00
10
208 or
2.30
8
240 or M400ML5AC4M CWA 458 2.00
300
5
25 PC2 2.0
3.9 24 360 1.85
3.82 2.01x3.01 3.12
11.2
n/a
n/a
E
277 or
1.70
5
480
1.00
50
480
M40048TAC4M CWA 458 1.00
300
3 15 PC2 2.0
3.9 24 360 1.85
3.82 2.01x3.01 3.12 11.0
n/a
n/a
E
HID
CORE & COIL
See page 5-23 for Reference
Drawings and Wiring Diagrams.
PAGE 5-20
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
METAL HALIDEFEATURING MULTI-5™
• 60 HZ.
• Minimum Starting
Temperature: -30° C
• Feature CWA Design
MH
1000-1500
WATT
Nom Dimensions
Capacitor
Ignitor
Max Open
Total
Max
UL
Input
Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht
Oval
Ht
(lbs.)
Number to lamp (ft) Top Rise
(1) 1000 WATT M47 METAL HALIDE LAMP
120
M1000120AC5M CWA 1080 9.00
425
23 28 PC3 2.9
4.75 24 480 n/a
n/a 2.01x3.01 4.0
18.0
n/a
n/a
D
230
M1000230AC5M CWA 1080 4.70
420
13 46 PC3 3.4
5.30 30 440 n/a
n/a
2.91
3.87 21.0
n/a
n/a
C
120 or
9.00
20
D
277 or M1000TRIAC5M CWA 1080 3.90
435
10 17 PC3 3.0
4.95 24 480 n/a
n/a 2.01x3.01 4.0
19.0
n/a
n/a
D
347
3.20
8
E
120 or
8.95
20
208 or
5.15
15
D
425
16 PC3 2.9
5.05 24 480 n/a
n/a 2.01x3.01 4.0
22.0
n/a
n/a
M1000MLTAC5M CWA 1080
240 or
4.50
10
277
3.90
10
120 or
9.15
20
F
5.25
15
E
208 or
420
10 25 PC3 2.9
5.05 24 480 n/a
n/a 2.01x3.01 4.0
22.0
n/a
n/a
E
240 or M1000ML5AC5M CWA 1080 4.55
277 or
3.95
10
E
480
2.30
6
E
480
M100048TAC5M CWA 1080 2.30
410
6 15 PC3 2.85
4.80 24 480 n/a
n/a 2.01x3.01 4.0
22.0
n/a
n/a
D
480
M100048TAN5M CWA 1080 2.30
410
6 15 PC3 2.85
4.75 24 480 n/a
n/a 2.01x3.01 3.9
22.0
n/a
n/a
A
(1) 1250 WATT M180 METAL HALIDE LAMP
120 or
12.00
30
F
208 or
6.90
20
D
240 or M1250MLTAC5M CWA 1360 6.00
420
15 17 PC3 4.4
6.4 32 440 n/a
n/a 1.97x3.66 3.88 25.0
n/a
n/a
D
277
5.20
15
E
(1) 1500 WATT M48 METAL HALIDE LAMP
230 M1500230AC5M CWA 1605 7.00
430
20 46 PC3 4.38
6.18 42(2x21) 480 n/a
n/a 1.96x3.65 3.9
30.0
n/a
n/a
C
120 or
13.70
40
277 or M1500TRIAC5M CWA 1610 6.00
460
20 17 PC3 4.38
6.38 32 525 n/a
n/a 1.96x3.65 3.9
29.5
n/a
n/a
G
347
4.70
15
120 or
14.30
40
F
208 or M1500MLTAC5M CWA 1615 8.30
25
G
455
48 PC3 4.4
6.4 32 525 n/a
n/a 1.96x3.65 3.9
30.0
n/a
n/a
240 or
7.20
20
F
277
6.20
20
E
480
M150048TAC5M CWA 1620 3.50
445
10 15 PC3 4.4
6.4 32 525 n/a
n/a 1.96x3.65 3.9
30.0
n/a
n/a
E
See page 5-23 for Reference
Drawings and Wiring Diagrams.
HID
CORE & COIL
PAGE 5-21
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
MH
METAL HALIDE
DESCRIPTION
SUFFIX *
For Ballast Only
For Bracket Only (see pg. 5-7)
For Capacitor Only (see pg. 5-5, 5-6)
For Distributor Replacement Kit
(see pg. 5-13 thru 5-15)
For Canadian Distributor
Replacement Kit (see pg. 5-16)
For Dry-Capacitor & Ballast
(see pg. 5-6)
For Bracket & Capacitor
(see pg. 5-5, 5-7)
For Bracket & Dry-Capacitor
(see pg. 5-6, 5-7)
000
200
500
Wiring Diagram 31
Wiring Diagram 17
Wiring Diagram 32
Wiring Diagram 25
Wiring Diagram 33
500K
502K
518
700
718
Bracket
W
Wiring Diagram 16
S
M
L
BRef. Dwg.
1
PC1
PC2
PC3
L
4.00”
5.25”
7.75”
7.75”
W
0.75”
1.25”
2.75”
2.75”
M
3.35”
4.60”
6.10”
6.10”
S
0.25”
0.25”
0.25”
0.25”
See p. 5-7 for adjustable mounting brackets and detailed bracket drawings.
REFERENCE DRAWING 1
REFERENCE DRAWING PC1
2.625"
0.438"
A
.203" Dia Thru
4 Holes
2.188"
B
4 Holes ClearedB
A
for #10 Thru-Bolts
A
0.438"
0.438"
.199" Dia Thru
4 Holes
0.594"
B
MAX
0.594"
A
B
A
.250" Dia Thru
2 Holes
2.812˝
2 Holes Cleared
for #10 Thru-Bolts
0.656"
.218" Dia Thru
4 Holes
0.437"
B
.250" Dia Thru
2 Holes
0.438"
A
2.937"
1.750"
2.188"
2.437"
1.750"
2.438˝
2.188"
2.188"
3.500˝ 3.938˝
2.812"
2.625"
REFERENCE DRAWING PC2
2.437"
1.218"
2.812"
Four 0.250" Male
Quick Connect
Blade Terminals
3.125"
3.125"
3.750"
Wiring Diagram 42
Wiring Diagram 28
Reference Drawing
3
Reference Drawing
2
Cleared
Reference Drawing for8 Holes
#10 Thru-Bolts
1-A
A
Reference Drawing
4
B
MAX
B
MAX
4.250˝
2 Holes Cleared
for #10 Thru-Bolts
2 Holes Cleared
for #10 Thru-Bolts
0.625"
.250" Dia Thru
4 Holes
3.875˝
3.500"
2.500"
.199" Dia Thru
4 Holes
REFERENCE DRAWING PC3
4 Holes Cleared
Reference Drawing
for #10 Thru-Bolts
1
A
1.218"
3.938"
.203" Dia Thru
4 Holes
A
B
.250" Dia
Thru4.750˝
4.375˝
2 Holes
4.375˝
.250" Dia Thru
5.750˝
5.375˝
2 Holes
0.637"
.250" Dia Thru
4 Holes
A
0.637"
.250" Dia Thru
8 Holes
B
A
0.625"
.250" Dia Thru
8 Holes
B
.250" Dia Thru
2 Holes
A
Wiring Diagram 29
4.375"
4.250" 1.937"
4.375"
Four 0.250"
Male Quick
Connect
Terminals
4.250"
3.875"
1.937"
4.750"
4.750"
B
.250" Dia Thru
2 Holes
3.875"
3.875"
3.875"
1.937"
3.875˝
Four 0.250"
Male Quick
Connect
Terminals
WIRING DIAGRAMS
4.250"
4.250˝
Wiring Diagram 46
4.250" 1.937"
4.375"
5.375"
5.750"
4.375"
5.375"
5.750"
HID
CORE & COIL
Wiring Diagram 14
Reference Drawing
6
Reference Drawing
5
0.625"
.250" Dia Thru
8 Holes
.218" Dia Thru
4 Holes
B
A
0.625"
.250" Dia Thru
8 Holes
B
A
0.625"
.250" Dia Thru
4 Holes
B
A
B
.250" Dia Thru
2 Holes
.250" Dia Thru
2 Holes
1.062"
.250" Dia Thru
2 Holes
Reference Drawing
8
Reference Drawing
7
0.687"
A
3.437"
Wiring
Diagram 15
3.875"
4.250" 1.937"
4.375"
5.375"
Wiring Diagram 30
2.750"
3.437"
3.875"
4.250"
3.437"
4.125"
1.937"
4.375"
5.375"
5.750"
Wiring Diagram 483.875"
4.250" 1.937"
4.375"
4.750"
5.750"
Reference Drawing
13
Reference Drawing
15
Reference Drawing
14
PAGE 5-22
B
0.843"
0.812"
3.937"
3.500"
Reference Drawing
16
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
PULSE START METAL HALIDE
PULSE START
MH
• 6 0 Hz
• Minimum starting
temperature: -30° C
• Normal and High Power Factor
models available
35/39-100 WATT
Nom Dimensions
Capacitor
Ignitor
Max Open
Total
Max
UL
Input
Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht
Oval
Ht
(lbs.)
Number to lamp (ft) Top Rise
(1) 35/39 WATT M130 METAL HALIDE LAMP
120 or
.84
2
277 or
M35TRILC3M HX-HPF 54
.40
235
1
4 PC1 0.85
2.15 5 300 1.26
2.36 1.31x2.16 2.2
1.7
MH100-3A
5
A
347
.30
1
120 or
.82
2
208 or
.48
1
M35MLTLC3M HX-HPF 50
230
3 PC1
240 or
.42
1
277
.36
1
(1) 50 WATT M110 METAL HALIDE LAMP — Medium Base
120 or
1.30
3
277 or
M50TRILC3M HX-HPF 67
.61
250
2
5 PC1
347
.48
2
120 or
208 or
M50MLTLC3M HX-HPF 67
240 or
277
1.16
0.67
252
0.57
0.50
3
3
2
2
0.85
2.0
5
277
1.26
2.83
1.31x2.16
2.2
1.7
MH100-3A
5
A
1.05
2.55
6
300
1.26
2.83
1.31x2.16
2.2
4.25
MH100-3A
10
A
6
300
1.26
2.36
1.31x2.16
2.2
4.25
MH100-3A
10
A
3 PC1
1.05
2.55
3
Capacitors are available as an option for high power
factor operation.
A
B
E
B
A
A
C
A
See page 5-23 for Reference
Drawings and Wiring Diagrams.
PAGE 5-23
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
CORE & COIL
(1) 70 WATT M98 METAL HALIDE LAMP - Medium Base
120 or
1.85
4
277 or
M70TRILC3M HX-HPF 91
0.80
260
2
4 PC1 1.5
2.65 8 280 1.65
2.83 1.31x2.16 2.2
5.0
MH100-3A
10
347
0.65
2
120 or
1.70
4
208 or
1.04
3
M70MLTLC3M
HX-HPF 95
250
3 PC1 1.33
2.88 8 300 1.65
2.83 1.31x2.16 2.2
4.25
MH100-3A
10
240 or
0.87
3
277
0.78
2
480
M7048TLC3M HX-HPF 100
0.50
250
1
6 PC1 1.38
2.88 8 300 1.65
2.83 1.31x2.16 2.2
4.25
MH100-3A
10
(1) 70 WATT M85 METAL HALIDE LAMP - Double Ended
120 or
1.70
4
208 or
1.04
3
250
3 PC1 1.38
2.88 8 300 1.65
2.83 1.31x2.16 2.2
4.25
MH70-3B
10
M70MLTLC3D HX-HPF 95
240 or
0.87
3
277
0.78
2
(1) 100 WATT M90 OR M92 METAL HALIDE LAMP - Medium Base
120 or
2.50
7
277 or
M100TRILC3M HX-HPF 125
1.10
265
3
4 PC1 1.6
2.95 12 280 1.65
2.83 1.31.2.16 3.13
5.5
MH100-3A
10
347
0.90
3
120 or
2.40
5
208 or
1.45
4
M100MLTLC3M HX-HPF 130
260
13 PC1 1.5
2.8 12 300 1.65
2.83 1.31x2.16 3.12
5.0
MH100-3A
10
240 or
1.20
3
277
1.00
3
480
M10048TLC3M HX-HPF 132
0.62
285
2
6 PC1 1.7
3.0 10 300 1.65
2.83 1.31x2.16 2.7
5.5
MH100-3A
10
(1) 100 WATT M91 METAL HALIDE LAMP - Double Ended
120 or
2.40
5
208 or
1.45
4
M100MLTLC3D HX-HPF 130
260
13 PC1 1.5
2.6 12 300 1.65
2.83 1.31x2.16 3.12
5.0
MH70-3B
10
240 or
1.20
3
277
1.00
3
PULSE START
MH
150-200 WATT
HID
CORE & COIL
HID CORE & COIL BALLASTS
• 60 Hz
• Minimum Starting
Temperature: -40° C
• Feature CWA Design
PULSE START METAL HALIDE
Nom Dimensions
Capacitor
Ignitor
Max Open
Total
Max
UL
Input
Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht
Oval
Ht
(lbs.)
Number to lamp (ft) Top Rise
(1) 150 WATT M102/M142 METAL HALIDE LAMP - Medium Base
120 or
3.32
10
277 or
M150TRILC3M HX-HPF 185
1.48
245
4
5 PC1 2.38
3.65 16 280 1.65
2.83 1.56x2.69 2.69
7.3
MH100-3A
10
D
347
0.65
2
120 or
3.32
10
208 or M150MLTLC3M HX-HPF 185
1.93
5
245
3 PC1 2.38
3.88 16 300 1.65
2.83 1.56x2.69 2.69
7.3
MH100-3A
10
A
240 or
1.66
5
277
1.48
4
120 or
1.50
4
C
208 or M150MLTAC3M
CWA 188
0.90
210
3
9 PCI 2.5
3.75 16 330 1.65
3.82
n/a
n/a
7.1
MH150-1A
10
D
240 or
0.75
3
C
277
0.65
2
C
480
M15048TLC3M HX-HPF 185
1.00
260
3
6 PC1 2.3
3.6 16 280 1.65
2.83 1.56x2.69 2.69
7.0
MH100-3A
10
F
(1) 150 WATT M81 METAL HALIDE LAMP - Double Ended
120 or
3.32
10
208 or
1.93
5
M150MLTLC3D HX-HPF 185
245
3 PC1 2.38
3.88 16 277 1.65
2.83 1.56x2.69 2.69
7.3
MH70-3B 10
D
240 or
1.66
5
277
1.48
4
(1) 175 WATT M152 METAL HALIDE PULSE START LAMP
RX-NPF
1.50
n/a
n/a
n/a
n/a
277
P175277RCEM
199
277
3
1 RX1 2.3
3.4 12 300
3.9
MH350-1A 10
C
RX-HPF
1.25
1.6
2.8 1.31x2.16 3.9
120 or
1.84
5
277 or P175TRIAC3M CWA 208 0.79
308
2 12 PC1 2.5
3.6 10 400 1.6
2.8 1.31x2.16 3.9
6.8
MH350-1
10
B
347
0.63
2
120 or
2.09
5
3
208 or P175MLTAC3M CWA 208 1.26
306
9 PC1 2.5
3.6 10 400 1.6
2.8 1.31x2.16 3.9
6.8
MH350-1A 10
A
240 or
1.02
3
277
0.96
2
120 or
1.95
5
208 or P175MLTAC3L CWA 198 1.10
285
3
9 PC1 3.10
4.20 11 370 1.65
2.83
n/a
n/a
8.5
MH350-1A 2
A
240 or
1.00
3
277
0.80
2
120 or
1.70
5
3
208 or P175MLTAC4L CWA 198 0.95
270
9 PC2 1.77
3.3 12.5 330 1.55
2.83
n/a
n/a
8.45 MH350-1A 10
A
240 or
0.85
3
277
0.75
2
120 or
1.80
5
208 or
1.05
3
240 or P175ML5AC3M CWA 210 0.90
295
3 26 PC1 2.6
4.0 10 400 1.6
2.8
2.7
2.7
8.0
MH350-1A 10
B
277 or
0.80
2
480
0.45
2
480
P17548TAC3L CWA 198 0.50
285
2 11 PC1 3.10
4.20 11 360 1.65
2.83
n/a
n/a
8.5
MH350-1A 2
A
480
P17548TAC4L CWA 198 0.40
275
2 11 PC2 1.80
3.5 12.5 330 1.6
2.8
n/a
n/a
9.6
MH350-1A 10
A
(1) 200 WATT M136 METAL HALIDE PULSE START LAMP
277
P200277RCEM RX-HPF 218 0.92
277
4
1 RX1 1.0
2.8 13 280
1.6
3.6
n/a
n/a
4.7
MH350-1A 10
A
120 or
277 or P200TRIAC3M CWA 240
347
120 or
208 or
240 or P200ML5AC3M CWA 233
277 or
480
480
P20048TAC3M CWA 232
2.70
1.04
310
0.87
2.66
1.52
1.31
303
1.12
0.68
0.50
305
6
3 12 PC1 2.8
3
6
4
3 26 PC1 2.7
3
2
2 11 PC1 2.8
4.0
11 400
1.6
2.8
2.7
3.6
8.0
MH350-1A
10
C
4.0
11 400
1.6
2.7
n/a
n/a
8.0
MH350-1A
10
C
4.1
11 400
1.6
2.8 1.56x2.69 2.7
8.5
MH350-1
10
C
PAGE 5-24
HID CORE & COIL BALLASTS
PULSE START METAL HALIDE
• 60 Hz
• Minimum Starting
Temperature: -40° C
• CWA and High Power
Factor Models Available
PULSE START
MH
250-320 WATT
See page 5-29 for Reference
Drawings and Wiring Diagrams.
PAGE 5-25
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
CORE & COIL
Nom Dimensions
Capacitor
Ignitor
Max Open
Total
Max
UL
Input
Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht
Oval
Ht
(lbs.)
Number to lamp (ft) Top Rise
(1) 250 WATT M153 METAL HALIDE PULSE START LAMP
RX-NPF
2.00
n/a
n/a
n/a
n/a
277
P250277RCEM
278
5
1 RX1 1.0
2.8 17.5 300
4.8
MH350-1A 10
A
277
RX-HPF
1.25
1.6
3.7
n/a
n/a
120 or
2.61
8
277 or P250TRIAC4M CWA 300 1.28
292
3
12 PC2 1.4
3.4 14 400 1.6
3.7
2.3
4.0
9.0
MH350-1A 10
A
347
1.09
3
120 or
2.40
8
5
208 or P250MLTAC40 CWA 291 1.40
277
9 PC2 1.45
3.10 17 360 1.6
3.7
2.3
3.1
9.0
MH350-1A 10
A
240 or
1.20
5
277
1.05
3
120 or
2.50
8
5
208 or P250MLTAC4L CWA 283 1.50
270
9 PC2 2.05
3.65 17 360 1.65
3.82
2.3
3.1
10.9
MH350-1A 15
A
240 or
1.30
5
277
1.10
3
120 or
2.45
8
208 or
1.42
5
240 or P250ML5AC4M CWA 285 1.22
290
5
26 PC2 2.0
3.9 14 400 1.6
3.7 1.56x2.69 3.1
11.3
MH350-1A 10
A
277 or
1.05
3
480
0.62
2
120 or
2.45
8
208 or
1.42
5
240 or P250ML5AC4M CWA 285 1.22
290
5
26 PC2 2.0
3.9 14 400 1.6
3.7 1.56x2.69 3.1
11.3
MH350-1A 10
A
277 or
1.05
3
480
480
P25048TAC4L
CWA 283 0.60
275
2
11 PC2 1.9
3.6 17 360 1.65
3.82
n/a
n/a
10.0
MH350-1A 10
A
(1) 320 WATT M154 METAL HALIDE PULSE START LAMP
RX-NPF
3.05
10
n/a
n/a
n/a
n/a
277
P320277RCEM
348
277
1 RX1 1.5
3.3 22.5 280
6.8
MH350-1A 10
A
RX-HPF
1.51
6
1.8
3.6
n/a
n/a
120 or
4.50
8
277 or P320TRIAC4M CWA 370 2.00
281
4
12 PC2 2.0
3.7 20.5 400 1.6
3.7
2.9
3.6
11.0
MH350-1A 10
C
347
1.50
3
120 or
3.10
9
5
208 or P320MLTAC40 CWA 364 1.80
275
9 PC2 2.0
3.9 21.0 360 1.85
3.82
2.9
3.6
11.0
MH350-1A 10
A
240 or
1.55
5
277
1.35
4
120 or
4.00
10
208 or
2.40
7
240 or P320ML5AC4M CWA 370 2.10
280
5
26 PC2 2.0
3.9 20.5 360 1.8
3.7 1.91x2.91 3.6
11.3
MH350-1A 10
D
277 or
1.85
5
480
1.06
3
120 or
4.00
10
208 or
2.40
7
240 or P320ML5AN4M CWA 405 2.10
282
5
26 PC2 2.0
3.86 20.5 360 1.85
3.82
1.75
3.1
11.3
MH350-1A 10
A
277 or
1.85
5
480
1.06
3
120 or
3.10
10
208 or
1.80
7
240 or P320ML5AC4L CWA 363 1.55
275
8
26 PC2 1.88
3.8 21 360 n/a
n/a
2.91
3.13
12.0
MH350-1A 10
A
277 or
1.35
5
480
0.80
3
PULSE START
MH
HID
CORE & COIL
320-350 WATT
• 60 Hz
• Minimum Starting
Temperature: -40° C
• Feature CWA Design
HID CORE & COIL BALLASTS
PULSE START METAL HALIDE
Nom Dimensions
Capacitor
Ignitor
Max Open
Total
Max
UL
Input
Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht
Oval
Ht
(lbs.)
Number to lamp (ft) Top Rise
(1) 350 WATT M131 METAL HALIDE PULSE START LAMP
120 or
3.10
8
208 or
1.80
5
240 or P320ML5AN4L CWA 363 1.55
275
5
26 PC2 1.88
3.8 21 360 1.85
3.82
n/a
n/a
12.0
MH350-1A 10
A
277 or
1.35
4
480
0.80
3
480
CWA 364 0.80
280
3
11 PC2 2.0
3.9 21 360 1.85
3.82
n/a
n/a
11.0
MH350-1A 10
A
P32048TAC4L
RX-NPF
3.80
—
—
—
—
277
377
277
8
1 RX1 1.5
3.3 22.5 300
6.8
MH350-1
10
A
P350277RCEM
RX-HPF
2.34
n/a
n/a 1.56x2.69 3.9
120 or
4.00
10
277 or P350TRIAC4M CWA 405 2.00
280
5 12 PC2 2.0
4.0 21 400 n/a
n/a
2.9
3.1
11.5 MH350-1A 10
C
347
1.50
3
120 or
3.40
9
208 or P350MLTAC4M
2.00
6
CWA 400
275
9 PC2 2.0
3.9 22 360 n/a
n/a
2.7
3.9
11.0 MH350-1A 10
C
240 or
1.70
5
277
1.45
4
120 or
2.40
9
208 or
6
P350MLTAN4M CWA 400 2.00
275
47 PC2 2.0
3.9 22 360 n/a
n/a
2.7
3.9
11.0 MH350-1A 10
A
240 or
1.70
5
277
1.45
4
120 or
4.22
10
208 or
2.49
7
240 or P350ML5AC4M CWA 405 2.16
282
5 26 PC2 2.0
3.9 21 400 n/a
n/a 1.91x2.91 3.1
11.3 MH350-1A 10
D
277 or
1.87
5
480
1.09
3
120 or
4.22
10
208 or
2.49
7
240 or P350ML5AN4M CWA 405 2.16
282
5 26 PC2 2.0
3.9 21 400 n/a
n/a 1.91x2.91 3.1
11.3 MH350-1A 10
D
277 or
1.87
5
480
1.09
3
120 or
3.35
10
208 or
1.90
7
240 or P350ML5AC4L CWA 397 1.65
275
9 26 PC2 1.88
3.8 22 360 1.85
3.82
2.69
3.9
12.0 MH350-1A 10
B
277 or
1.45
5
480
0.85
3
120 or
3.35
9
208 or
1.90
6
240 or P350ML5AN4L CWA 397 1.65
275
5 26 PC2 1.88
3.8 22 360 1.85
3.82
2.69
3.9
12.0 MH350-1A 10
A
277 or
1.45
4
480
0.85
3
480
P35048TAC4L CWA 397 0.85
280
3 11 PC2 2.00
3.9 22 360 1.85
3.82
2.69
3.9
11.0 MH350-1A 10
C
See page 5-29 for Reference
Drawings and Wiring Diagrams.
PAGE 5-26
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
PULSE START METAL HALIDE
• 60 Hz
• Minimum Starting
Temperature: -40° C
• CWA and High Power
Factor Models Available
PULSE START
MH
400 WATT
Nom Dimensions
Capacitor
Ignitor
Max Open
Total
Max
UL
Input
Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht
Oval
Ht
(lbs.)
Number to lamp (ft) Top Rise
(1) 400 WATT M135 METAL HALIDE PULSE START LAMP
120 or
4.40
10
277 or P400TRIAC4M CWA 457 2.01
287
5 12 PC2 2.0
3.8 24 400 1.8
3.6
2.9
3.1
11.0 MH350-1A 10
D
347
1.52
4
120 or
4.05
10
277 or P400TRIAN4M CWA 454 1.95
285
5 12 PC2 2.0
3.9 24 400 1.8
3.6
2.9
3.1
11.0 MH350-1A 10
D
347
1.40
4
120 or
3.90
10
B
208 or P400MLTAC4L CWA 454 2.25
280
7
9 PC2 2.30
4.20 26 330 1.85
3.82
n/a
n/a
11
MH350-1A 10
B
240 or
1.95
5
B
277
1.70
5
C
120 or
4.00
10
208 or
2.40
7
240 or P400ML5AC4M CWA 457 2.10
286
5 26 PC2 2.0
3.9 24 400 1.8
3.7 1.91x2.91 3.1
11.3 MH350-1A 10
D
277 or
1.85
5
480
1.06
3
120 or
3.90
10
208 or
2.25
7
240 or P400ML5AN4M CWA 455 1.95
286
5 26 PC2 2.0
3.9 24 400 1.8
3.7 1.91x2.91 3.1
11.3 MH350-1A 10
D
277 or
1.70
5
480
0.95
3
480
P40048TAC4L CWA 455 1.00
275
3 11 PC2 2.3
4.2 28 330 1.85
3.82
n/a
n/a
12
MH350-1A 10
D
480
P40048TAC4M CWA 457 1.00
285
3 11 PC2 2.0
3.9 24 400 1.8
3.6
3.7
3.1
11.3 MH350-1A 10
D
See page 5-29 for Reference
Drawings and Wiring Diagrams.
HID
CORE & COIL
PAGE 5-27
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
PULSE START
MH
HID
CORE & COIL
450-1000 WATT
• 60 Hz
• Minimum Starting
Temperature: -40° C
• CWA and High Power
Factor Models Available
HID CORE & COIL BALLASTS
PULSE START METAL HALIDE
Nom Dimensions
Capacitor
Ignitor
Max Open
Total
Max
UL
Input
Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht
Oval
Ht
(lbs.)
Number to lamp (ft) Top Rise
(1) 450 WATT M144 METAL HALIDE PULSE START LAMP
120 or
4.40
10
208 or
2.60
8
285
9 PC2 2.3
4.0 26.5 400 1.8
4.7
2.9
3.5
11.0 MH350-1A 10
C
P450MLTAC4M CWA 510
240 or
2.20
7
277
1.90
5
120 or
4.44
10
208 or
2.56
8
240 or P450ML5AC4M CWA 510 2.38
305
7 26 PC2 2.6
4.7 26.5 400 1.8
4.7 1.91x2.91 3.9
12.0
MH350-1
10
D
277 or
1.92
5
480
1.22
4
480
P45048TAC4M CWA 511 1.40
305
10 11 PC2 2.7
4.7 26.5 400 0.8
4.6
2.9
3.5
12.0 MH350-1A 10
D
(1) 750 WATT M149 METAL HALIDE PULSE START LAMP
120 or
7.05
15
B
277 or P750TRIAC5M CWA 820 3.05
340
8 12 PC3 2.8
4.6 28 425 n/a
n/a
2.91
3.9
18.0
P750-1B
10
C
347
2.45
8
C
120 or
7.10
18
D
A
208 or
4.10
10
340
9 PC3 2.8
4.8 28 400 n/a
n/a
2.91
3.9
18.0
P750-1B
10
P750MLTAC5M CWA 825
240 or
3.55
10
B
277
3.10
8
B
120 or
6.95
18
C
208 or
4.00
10
C
240 or P750ML5AC5M
CWA 820 3.50
340
10 26 PC3 2.8
4.9 28 400
n/a
n/a
2.9
3.9
19.0
P750-1B
16
D
277 or
3.00
8
D
480
1.75
5
C
480
P75048TAC5M CWA 822 1.80
335
5 11 PC3 2.8
4.8 28 400 n/a
n/a
2.91
3.9
18.0
P750-1B
10
D
(1) 875 WATT M166 METAL HALIDE PULSE START LAMP
120 or
8.50
20
D
C
208 or
5.30
15
395
9 PC3 2.8
4.5 24 440 n/a
n/a
2.9
3.9
17.5 HPS1000-48 10
P875MLTAC5M CWA 945
240 or
4.30
10
A
277
3.80
10
C
120 or
8.05
20
E
208 or
4.65
12
C
240 or P875ML5AC5M CWA 950 4.05
395
10 26 PC3 2.8
4.8 24 440 n/a
n/a
2.9
3.9
19.4 HPS1000-4B 10
B
277 or
3.50
10
C
480
2.00
5
C
(1) 1000 WATT M141 METAL HALIDE PULSE START LAMP
120 or
9.00
20
208 or
5.20
15
420
9 PC3 2.9
5.1 24 480 n/a
n/a
2.9
3.9
22.0 HPS1000-4B 20
D
P1000MLTAC5M CWA 1080
240 or
4.50
10
277
3.90
10
120 or
8.95
20
G
208 or
5.15
15
B
240 or P1000ML5AC5M CWA 1080 4.45
420
10 26 PC3 2.9
5.1 24 480 n/a
n/a
2.9
3.9
22.0 HPS1000-4B 20
C
277 or
3.85
10
C
480
2.25
10
C
480
P100048TAC5M CWA 1080 2.55
410
10 11 PC3 2.8
4.8 24 480 n/a
n/a
2.9
3.9
22.0 HPS1000-4B 15
D
See page 5-29 for Reference
Drawings and Wiring Diagrams.
PAGE 5-28
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
PULSE START
MH
HID CORE & COIL BALLASTS
PULSE START METAL HALIDE
DESCRIPTION
SUFFIX *
For Ballast Only
For Bracket Only (see pg. 5-7)
For Capacitor Only (see pg. 5-5, 5-6)
For Distributor Replacement Kit
(see pg. 5-13 thru 5-15)
For Canadian Distributor
Replacement Kit (see pg. 5-16)
For Dry-Capacitor & Ballast
(see pg. 5-6)
For Bracket & Capacitor
(see pg. 5-5, 5-7)
For Bracket & Dry-Capacitor
(see pg. 5-6, 5-7)
000
200
500
500K
REFERENCE DRAWING PC1
REFERENCE DRAWING PC2
4 Holes Cleared
for #10 Thru-Bolts
4 Holes Cleared
for #10 Thru-Bolts
A
A
B
MAX
B
MAX
2.812˝
2 Holes Cleared
for #10 Thru-Bolts
502K
3.875˝
2.438˝
4.250˝
2 Holes Cleared
for #10 Thru-Bolts
3.500˝ 3.938˝
4.375˝ 4.750˝
518
700
REFERENCE DRAWING PC3
718
REFERENCE DRAWING RX1
8 Holes Cleared
for #10 Thru-Bolts
A
B
MAX
Bracket
W
S
2 Holes Cleared
for #10 Thru-Bolts
M
L
BRef. Dwg.
PC1
PC2
PC3
RX1
L
5.25”
7.75”
7.75”
4.00”
W
1.25”
1.25”
2.75”
0.75”
M
4.60”
5.75”
6.10”
3.35”
4.250˝
S
0.25”
0.25”
0.25”
0.25”
3.875˝
4.375˝
5.375˝ 5.750˝
See p. 5-7 for adjustable mounting brackets and detailed bracket drawings.
Wiring Diagram 5
Wiring Diagram 11
Wiring Diagram 6
Wiring Diagram 12
Wiring Diagram 9
Wiring Diagram 26
Wiring Diagram 13
Wiring Diagram 47
WIRING DIAGRAMS
Wiring Diagram 1
Wiring Diagram 3
HID
CORE & COIL
Wiring Diagram 4
PAGE 5-29
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HPS
35-100
HID
CORE & COIL
WATT
• 60 Hz
• Minimum Starting
Temperature: -40° C
• Normal and High Power
Factor Models
HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUM
Nom Dimensions
Capacitor
Ignitor
Max Open
Total
Max
UL
Input
Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht
Oval
Ht
(lbs.)
Number to lamp (ft) Top Rise
(1) 35 WATT S76 HIGH PRESSURE SODIUM LAMP
120
2
2 1a 0.6
1.7 14 120 n/a
n/a 1.56x2.69 2.7
1.5 HPS150-3A
3
A
1233-251W ◆ R-HPF 3 43 0.65
1201
Permanently Attached
RX-NPF 0.85
120
2
120
S35120RCEM
44
1 5
0.6
1.7 14 240 —
—
1.9
2.3
1.0 HPS150-3A 10
A
RX-HPF
0.63
3
(1) 50 WATT S68 HIGH PRESSURE SODIUM LAMP
1233-35W ◆ R-HPF 3 60 0.90
120
5
2 1a 0.9
2.4 20 240 n/a
n/a 1.56x2.69 3.1
2.0 HPS150-3A
3
A
1201
Permanently Attached
RX-NPF 1.12
8
120
S50120RCEM
60
120
1 5
0.8
2.0 20 240 —
—
1.9
2.3
2.0 HPS150-3A 3
A
RX-HPF
0.90
5
120 or
1.24
5
208 or
0.60
3
130
3 PC1 1.3
2.7 5 300 1.2
2.2
2.2
2.2
4.1 HPS150-3A 5
A
S50MLTLC3M HX-HPF 66
240 or
0.52
3
277
0.45
2
(1) 70 WATT S62 HIGH PRESSURE SODIUM LAMP
1.30
120
5
2 1a
1.3
2.8 2.8 120 1.6
2.7
n/a
n/a
2.5
HPS150-3A
3
A
1233-142W ◆ R-HPF 83
120
Permanently Attached
RX-NPF
1.60
8
120
S70120RCEM
80
120
1 RX1 1.1
2.8 28 240
n/a
n/a
1.3
2.7
2.0
HPS150-3A
3
A
RX-HPF
1.30
4
230
S70230LC3M HX-HPF 88
1.00
120
2
35 PC1 1.9
3.2 10 280
1.6
2.7
1.3
2.7
5.7
HPS150-3A
3
A
120 or
1.50
5
S7027TLC3M HX-HPF 98
120
36 PC1 1.3
2.8
7 300
n/a
n/a
1.3
2.2
4.1
HPS150-3A
10
B
277
0.65
2
120 or
1.50
5
277 or S70TRILC3M HX-HPF 94 0.65
120
2
4 PC1 2.0
3.5 7 300 1.2
2.7 1.31x2.16 2.2
4.2 HPS150-3A 10
B
347
0.50
2
120 or
1.50
5
3
208 or S70MLTLC3M HX-HPF 98 0.88
120
3 PC1 1.3
2.8 7 300 1.2
2.8 1.31x2.16 2.2
4.2 HPS150-3A 10
B
240 or
0.75
3
277
0.65
2
480
S7048TLC3M HX-HPF 94
0.34
120
2
6 PC1 1.8
2.9 7 300 1.2
2.8
1.3
2.2
5.6
HPS150-3A 10
A
(1) 100 WATT S54 HIGH PRESSURE SODIUM LAMP -1233-10W ◆ R-HPF 3 117 1.80
120
8
2 1a 1.5
2.9 40 240 1.6
3.6
1.87
2.9
2.8 HPS150-3A
3
A
120 1
Permanently Attached
RX-NPF 115 2.24
10
120
S100120RCEM
120
1 5
1.50
2.8 40 240
—
—
1.8
2.7
2.0
HPS150-3A
10
A
RX-HPF 112 1.81
8
120 or
2.20
3
S10027TLC3M HX-HPF 122
120
36 PC1 2.0
3.4 10 330
1.6
2.7
1.3
2.7
5.9
HPS150-3A
10
B
277
0.95
2
120 or
2.20
8
277 or S100TRILC3M HX-HPF 130 0.95
120
3
5 PC1 2.0
3.5 10 330 1.2
2.7 1.31x2.16 2.7
5.9 HPS150-3A 10
B
347
0.69
2
120 or
2.20
8
208 or S100MLTLC3M HX-HPF 122 1.30
5
120
3 PC1 2.0
3.4 10 330 1.2
2.7
2.2
2.7
6.0 HPS150-3A 10
B
240 or
1.10
5
277
0.95
3
480
S10048TLC3M HX-HPF 135 0.57
120
2
6 PC1 2.0
3.3 10 277 1.6
2.8
1.3
2.2
6.2 HPS150-3A 5
E
1
3
◆
Also can be used on a 277 volt line in conjuction with the step down transformers
Capacitors are available as an option for High Power Factor operation
Ballast has built-in starter.
PAGE 5-30
See pages 5-34 and 5-35 for
Reference Drawings and Wiring Diagrams.
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUM
• 60 Hz
• Minimum Starting
Temperature: -40° C
• CWA, Normal and High Power
Factor Models
HPS
150-250
WATT
Ballast has built-in starter.
* Also can be used on a 277 volt line in conjunction with
the step-down transformers described on page 5-53.
3
Capacitors are available as an option for high power
factor operation.
◆
PAGE 5-31
See pages 5-34 and 5-35 for
Reference Drawings and Wiring Diagrams.
HID
CORE & COIL
Nom Dimensions
Capacitor
Ignitor
Max Open
Total
Max
UL
Input
Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht
Oval
Ht
(lbs.)
Number to lamp (ft) Top Rise
(1) 150 WATT S55 HIGH PRESSURE SODIUM LAMP
1233-154W ◆
R-HPF 3 171 2.40
120
8
2 1a
2.0
3.4 52 240
1.8
3.0
2.12
2.9
3.5
HPS150-3A
3
A
120 1
Permanently Attached
RX-NPF
4.40
120
S150120RCEM
168
120
5
1 5
2.0
3.1 15 240
n/a
n/a
2.0
2.9
3.3
HPS150-3A
3
A
RX-HPF
2.35
208
S150208LC3M HX-HPF 190 0.95
120
5
37 PC1 2.3
3.8 14 300 n/a
n/a
1.5
2.7
7.0
HPS150-3A 10
C
120 or
1.90
10
B
S15027TLC3M HX-HPF 295
185
36 PC1 2.5
3.9 14 280 n/a
n/a
2.7
2.7
7.0 HPS150-3A 10
277
0.80
5
A
120 or
3.00
10
B
277 or S150TRILC3M HX-HPF 188 1.35
120
5
5 PC1 2.3
3.7 14 300
1.6
2.8 1.56x2.69 2.7
7.0
HPS150-3A
10
C
347
1.00
4
B
120 or
1.90
10
B
5
A
208 or S150MLTLC3M HX-HPF 188 1.00
120
3 PC1 2.5
3.9 14 280
1.6
2.8
2.7
2.7
7.0
HPS150-3A
10
240 or
0.95
5
B
277
0.80
5
A
480
S15048TLC3M HX-HPF 189 0.72
120
3
6 PC1 3.0
4.5 14 277
1.6
2.7 1.56x2.69 2.7
8.7
HPS150-3A
10
D
(1) 150 WATT S56 HIGH PRESSURE SODIUM LAMP
120
1.65
5
1.50
3
208
CWA 188
210
9 PC1 2.5
3.9 20 240
1.6
3.6
n/a
n/a
8.0
HPS150-3A
10
D
S150MLTAC3M
240
0.85
3
277
0.75
3
(1) 200 WATT S66 HIGH PRESSURE SODIUM LAMP
R-NPF
2.80
8
— —
—
—
—
—
240
225
240
1 4
1.5
3.0
5.3
HPS450-1B
5
A
1233-183S
2.00
3
22.5 240
n/a
n/a 1.56X2.69 3.5
R-HPF 3
120
2.00
7
277
S200TRIAC4M
CWA 233 0.86
184
3
12 PC2 1.4
3.3 28 280
n/a
n/a 1.91x2.91 3.1
8.7
HPS400-3A
10
C
347
0.68
3
120 or
2.10
7
208 or
1.20
4
CWA 230
175
9 PC2 1.2
3.0 28 300
1.8
3.7 1.91X2.91 3.1
8.5
HPS400-3A
10
S200MLTAC4M
B
240 or
1.00
4
277
0.88
3
480
S20048TAC4M
CWA 240 0.56
172
2
34 PC2 2.0
3.8 28 280
1.6
4.6
1.7
3.1
11.0
HPS400-3A
10
C
(1) 250 WATT S50 HIGH PRESSURE SODIUM LAMP
R-NPF
3.50
10
— —
—
—
—
—
240
278
240
1 4
2.0
3.5
6.8 HPS450-1B
5
A
1233-24S
R-HPF
2.50
5
28 240 n/a
n/a
1.87
2.3
120
S250120AC4M CWA 295 2.50
185
8 38 PC2 1.8
3.7 35 330 n/a
n/a
1.8
3.1
10.3 HPS400-3A 10
A
230
S250230AC4M CWA 280 1.24
188
5 39 PC2 1.7
3.6 40 300 n/a
n/a
1.8
3.9
10.3 HPS400-3A 3
B
240
S250240AC4M CWA 295 1.20
185
4 40 PC2 1.8
3.7 35 330 n/a
n/a
1.8
3.1
10.3 HPS400-3A 10
A
120
2.50
8
277
S250TRIAC4M CWA 300 1.20
190
4 12 PC2 1.7
3.8 35 330 1.6
3.7 1.91x2.91 3.1
10.3 HPS400-3A 10
C
347
1.00
3
120
2.50
8
208
1.40
5
S250MLTAC4M CWA 295
190
9 PC2 1.8
3.7 35 330 1.6
3.7 1.91x2.91 3.1
10.3 HPS400-3A 10
A
240
1.20
4
277
1.10
4
120
2.50
8
208
1.40
5
240 S250ML5AC4M CWA 300 1.20
200
4 26 PC2 2.0
3.8 35 330 1.6
3.7 1.91x2.91 3.1
14.0 HPS400-3A 10
A
277
1.10
4
480
0.60
2
480
S250480AC4M CWA 285 0.62
200
2 39 PC2 1.8
3.7 35 280 1.8
4.6
n/a
n/a
10.4 HPS400-3A 5
A
480
S25048TAC4M CWA 285 0.62
200
2 11 PC2 1.8
3.7 35 280 1.6
3.7 1.91x2.91 3.1
10.4 HPS400-3A 5
A
HPS
400-430
WATTS
• 60 Hz
• Minimum Starting
Temperature: -40° C
• CWA, Normal and High Power
Factors Models Available
HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUMFEATURING MULTI-5™
Nom Dimensions
Capacitor
Ignitor
Max Open
Total
Max
UL
Input
Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht
Oval
Ht
(lbs.)
Number to lamp (ft) Top Rise
(1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP - 4 3/ ” Frame
230
S400230AC4M CWA 465 2.05
190
8 39 PC2 2.5
4.3 64 300 n/a
n/a
1.8
3.2
15.5 HPS400-3A 10
D
277
S400277AC4M CWA 460 1.70
192
5 41 PC2 2.32
4.1 55 240 1.8
4.6
1.8
3.9
14.0 HPS400-3A 10
D
120 or
3.95
10
277 or S400TRIAC4M
CWA 465 1.70
192
5 12 PC2 2.32
4.1 55 240 1.8
3.7 1.91x2.91 3.5
14.0 HPS400-3A 10
D
347
1.35
4
120 or
3.80
10
208 or
2.20
6
S400MLTAC4M CWA 463
190
9 PC2 2.32
4.1 55 240 1.8
3.7 1.91x2.91 3.5
14.0 HPS400-3A 10
D
240 or
1.80
5
277
1.70
5
120 or
3.95
10
208 or
2.30
6
240 or S400ML5AC4M CWA 465 2.00
190
5 26 PC2 2.44
4.3 55 240 1.8
3.7 1.91x2.91 3.5
14.0 HPS400-3A 10
D
277 or
1.70
5
480
1.00
3
480
S400480AC4M CWA 464 1.00
190
3 11 PC2 2.32
4.1 55 240 1.8
4.6
1.8
3.9
14.0 HPS400-3A 10
D
480
S40048TAC4M CWA 464 1.00
190
3 11 PC2 2.32
4.1 55 240 1.8
3.7 1.91x2.91 3.5
14.0 HPS400-3A 10
D
(1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP - 5 3/ ” Frame
120 or
3.90
10
277 or S400TRIAC5M CWA 467 1.70
200
5 12 PC2 2.2
4.1 48 280 2.0
4.7 1.91x2.91 3.9
16.0 HPS400-3A 10
E
347
1.35
4
120 or
3.95
10
208 or
2.30
6
200
9 PC3 2.25
4.1 48 280 2.0
4.7 1.91x2.91 3.9
16.0 HPS400-3A 10
D
S400MLTAC5M CWA 470
2.00
5
240 or
277
1.70
5
120 or
4.00
10
208 or
2.30
6
240 or S400ML5AC5M CWA 468 2.00
200
5 26 PC3 2.5
4.5 48 300 2.0
4.7 1.91x2.91 3.9
17.5 HPS400-3A 10
D
277 or
1.75
5
480
1.00
3
480
S40048TAC5M CWA 467 1.00
200
3 11 PC3 2.25
4.1 48 280 2.0
4.7 1.91x2.91 3.9
16.0 HPS400-3A 10
D
(1) 430 WATT SON AGRO HIGH PRESSURE SODIUM LAMP
120 or
4.50
10
208 or
2.50
8
205
9 PC2 2.2
4.3 48 330 2.0
4.7 1.91x2.91 3.9
11.0 HPS400-3A 10
D
S430MLTAC4M CWA 490
2.10
7
240 or
277
1.80
5
4
4
Capacitors are available as an option for high power
factor operation.
See pages 5-34 and 5-35 for
Reference Drawings and Wiring Diagrams.
HID
CORE & COIL
3
PAGE 5-32
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUM
• 6 0 Hz
• Minimum starting
temperature: -40° C
• CWA models available
HPS
600-1000
WATT
Nom Dimensions
Capacitor
Ignitor
Max Open
Total
Max
UL
Input
Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht
Oval
Ht
(lbs.)
Number to lamp (ft) Top Rise
(1) 600 WATT S106 HIGH PRESSURE SODIUM LAMP
120 or
5.10
20
208 or
3.10
15
CWA 640
240
9 PC3 3.0
5.0 55 300 1.8
4.7 1.91x2.91 3.9
21.0 HPS600-1B 10
A
S600MLTAC5M
240 or
2.70
10
277
2.35
10
(1) 1000 WATT S52 HIGH PRESSURE SODIUM LAMP
220 or
5.15
15
230 or S1000230AC5M
CWA 1100 5.00
405
15 39 PC3 4.0
5.8 36 540
n/a
n/a
3.66
4.25
25.5
HPS1000-4B 10
D
240
4.80
15
120 or
9.50
20
S100024TAC5M
CWA 1100
440
40 PC3 3.7
5.7 26 525
n/a
n/a
1.8
4.3
26.0 HPS1000-4B 10
C
240
4.80
10
120 or
9.60
20
277 or S1000TRIAC5M CWA 1100 4.30
440
10 12 PC3 3.8
5.8 26 525
n/a
n/a
1.9
2.9
27.0
HPS1000-4B 15
D
347
3.40
10
120 or
9.50
20
5.50
15
208 or S1000MLTAC5M
CWA 1100
440
9 PC3 3.7
5.7 26 525
n/a
n/a 1.91x2.91 4.3
26.0
HPS1000-4B 15
C
240 or
4.80
10
277
4.20
10
120 or
9.10
20
5.40
15
208 or
240 or S1000ML5AC5M CWA 1048 4.60
440
10 26 PC3 3.7
5.6 26 480
n/a
n/a 1.91x2.91 4.3
26.0 HPS1000-4B 15
D
277 or
4.10
10
480
2.45
8
480
S1000480AC5M
CWA 1100 2.45
440
8
11 PC3 3.7
6.0 26 500
n/a
n/a
1.8
4.3
25.0 HPS1000-4B 15
D
480
S100048TAC5M
CWA 1100 2.45
440
8
11 PC3 3.7
6.0 26 525
n/a
n/a 1.91x2.91 4.3
25.0
HPS1000-4B 15
D
See pages 5-34 and 5-35 for
Reference Drawings and Wiring Diagrams.
HID
CORE & COIL
PAGE 5-33
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
HPS
HIGH PRESSURE SODIUM
DESCRIPTION
SUFFIX *
For Ballast Only
For Bracket Only (see pg. 5-7)
For Capacitor Only (see pg. 5-5, 5-6)
For Distributor Replacement Kit
(see pg. 5-13 thru 5-15)
For Canadian Distributor
Replacement Kit (see pg. 5-16)
For Dry-Capacitor & Ballast
(see pg. 5-6)
For Bracket & Capacitor
(see pg. 5-5, 5-7)
For Bracket & Dry-Capacitor
(see pg. 5-6, 5-7)
REFERENCE DRAWING 1
000
200
500
REFERENCE DRAWING 1a
2.625"
0.438"
B
A
0.438"
0.594"
A
.203" Dia Thru
4 Holes
2.188"
.203" Dia Thru
4 Holes
500K
B
B
A
2.625"
0.438"
0.438"
.199" Dia Thru
A
4 Holes
0.438"
.250" Dia Thru
.199" Dia Thru
2 Holes
4 Holes
.250" Dia Thru
2 Holes
0.594" B
A
2.188"
0.438"
0.594"
0.594"
0.438"
0.438"
502K
1.750"
2.188"
518
1.750"
2.625"
2.188"
700
2.437"
1.750"
2.188"
2.188"
2.812"
1.750"
2.188"
.203" Dia Thru
4 Holes
2.188"
2.625"
1.218"
2.437"
2.812"
Reference Drawing
1
Reference
Drawing
REFERENCE
DRAWING
4
1
Reference Drawing
1-A
Reference
Drawing
REFERENCE
DRAWING
1-A
Reference Drawing
2
Reference D
2
5
"
A
0.656"
.218" Dia Thru
4 Holes
0.437"
B
B
A
.250"Bracket
Dia Thru
W
2 Holes
3.937"
3.500"
2.500"
4.250"
B
A
Connect
Terminals
Reference Drawing
6
Reference Drawing
4 Holes Cleared
for #10 Thru-Bolts
6
A
0.687"
A
B
0.625"
.250" Dia Thru
8 Holes
A
.218" Dia Thru
4 Holes
B
A
0.687"
1.062"
.218" Dia Thru
4 Holes
B
.250" Dia Thru
2 Holes
3.875˝
3.500˝ 3.938˝
4.250" 1.937"
5.375"
4.375"
4.375˝ 4.750˝
4.250" 1.937"
3.437"
4.375"
3.875"
5.375"
4.250" 1.937" 5.750"
5.750"
4.375"
Reference Drawing
8
Reference Drawing
7
0.625"
.250" Dia Thru
8 Holes
A
0.625"
.250" Dia Thru
4 Holes
B
A
A
B
1.062"
3.437"
3.437"
2.750"
3.875"
5.375"
REFERENCE
DRAWING PC3
5.375"
HID
CORE & COIL
4.250˝
2 Holes Cleared
for #10 Thru-Bolts
3.875"
4.375"
4.375"
REFERENCE DRAWING PC2
2.812˝
0.625"
.250" Dia Thru
8 Holes
.250" Dia Thru
2 Holes
5.750"
2.750"
3.437"
3.437"
4.125"
3.437"
4.125"
5.750"
Reference Drawing
13
Reference Drawing
B
MAX
13
8 Holes Cleared
for #10 Thru-Bolts
A
Reference Drawing
14
Reference Drawing
14
2 Holes Cleared
for #10 Thru-Bolts
B
.250" Dia Thru
2 Holes
.250" Dia Thru
2 Holes
4.250˝
3.875"
4.250"
4.750"
B
MAX
Four 0.250"
1.937"
B
4.750"
4.750"
Reference Drawing
4 Holes5
Cleared
for #10 Thru-Bolts
Reference Drawing
A
5
B
2 Holes Cleared
for #10 Thru-Bolts
.250" Dia Thru
2 Holes
PC1
4.375"
3.875"
4.250" 1.937"
4.375"
1.937"
Reference Drawing
REFERENCE4 DRAWING
2.438˝ Male Quick
4.250"
4.750"
A
Four 0.250"
Male Quick
Connect
Terminals Four 0.250"
Male Quick
Connect
Terminals
3.875"
4.250" 1.937"
4.375"
1.937" 3.875"
B
.250" Dia Thru
2 Holes
3.750"
3.875"
4.250"
0.625"
.250" Dia Thru
8 Holes
3.875"
B
3.125"
B
MAX
A
A
A
0.637"
.250" Dia Thru
4 Holes
.250" Dia Thru
2 Holes
.250" Dia Thru
2 Holes
3.125"
Reference Drawing
3
.250" Dia Thru
2 Holes
A
B
0.625"
.250" Dia Thru
4 Holes
.250" Dia Thru
2 Holes
2.937"
See p. 5-7 for adjustable mounting brackets and detailed bracket drawings.
0.637"
.250" Dia Thru
8 Holes
0.637"
.250" Dia Thru
4 Holes
0.625"
.250" Dia Thru
4 Holes
L 2.437" W
M
S 0.250" Male
Four
Quick Connect
1.218"
Blade Terminals
4.00”
0.75” 3.35” 0.25”
2.812"
.199" Dia Thru0.25”
5.25” 1.25” 4.60”
4 Holes
7.75” 1.25” 5.75” 0.25”
Drawing
B
0.843"
S0.812"
M
L
BRef. Dwg.
1, 1a, 5
PC1, 4
PC2, PC3
A
3.875˝
4.375˝
5.375˝ 5.750˝
3.875"
1.937"
4.375"
5.375"
5.750"
Reference Drawing
15
4.250" 1.937"
4.375"
4.750"
Reference Drawing
16
PAGE 5-34
3.500"
3.938"
.203" Dia Thru
4 Holes
718
3.500"
3.938"
1.218"
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
HPS
HIGH PRESSURE SODIUM
WIRING DIAGRAMS
Wiring Diagram 1
Wiring Diagram 2
Wiring Diagram 9
Wiring Diagram 11
Wiring Diagram 36
Wiring Diagram 37
Wiring Diagram 3
Wiring Diagram 12
Wiring Diagram 4
Wiring Diagram 38
Wiring Diagram 26
Wiring Diagram 39
Wiring Diagram 5
Wiring Diagram 34
Wiring Diagram 40
Wiring Diagram 6
HID
CORE & COIL
Wiring Diagram 35
Wiring Diagram 41
PAGE 5-35
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
MH & HPS
50 HZ
• 50 Hz
• Minimum Starting
Temperature: -40° C
• CWA, Normal and High Power
factor models available
HID CORE & COIL BALLASTS
50 HERTZ
Nom Dimensions
Capacitor
Ignitor
UL
Max Open
Total
Max Bench
Input
Catalog*
Circuit
Input
Input Circuit
Fuse
Wir Ref Min
Dry Film
Oil Filled
Wt. Catalog Dist. Top
Volts
Number
Type
Watts
Curr. Volt.
Rating
Dia Dwg
A B µF Volt Dia
Ht
Oval
Ht (lbs.) Number lamp Rise
(1) 175 WATT M57 METAL HALIDE LAMP
230
M175230AC3M CWA
205
1.17 312
2
14 PC1 2.25 3.55 12 400 1.56 3.74
1.5
3.13 6.7
n/a
n/a
C
(1) 250 WATT M58 METAL HALIDE LAMP
230
M250230AC3M CWA
282
1.55 285
3
14 PC1 3.0 4.3 18 400 n/a
n/a 2.01x3.01 3.1 9.0
n/a
n/a
D
(1) 400 WATT M59 METAL HALIDE LAMP
230
M400230AC4M CWA
435
2.44 300
5
14 PC2 2.13 3.73 28 425 n/a
n/a 1.91x2.91 3.9 13.0 n/a
n/a
D
(1) 1000 WATT M47 METAL HALIDE LAMP
230 M1000230AC5M CWA
1080
5.33 405
15
14 PC3 3.44 5.24 30 440 n/a
n/a 2.01x3.01 3.9 24.0 n/a
n/a
C
(1) 1500 WATT M48 METAL HALIDE LAMP
230 M1500230AC5M CWA
1605
7.29 430
20
14 PC3 4.38 6.18 42(2x21) 480 n/a
n/a 1.97x3.66 3.9 30
n/a
n/a
C
(1) 200 WATT S66 HIGH PRESSURE SODIUM LAMP
R-NPF
2.90
8
— —
—
—
—
—
240
225
240
1
4
1.5 3.0
5.4 HPS460-1B 10
D
1238-183S
R-HPF
2.06
3
28 240 n/a
n/a 1.91x2.91
3.1
(1) 250 WATT S50 HIGH PRESSURE SODIUM LAMP
R-NPF
3.60
10
— —
—
—
—
—
230
278
230
1
4
2.0 3.5
7.1 HPS460-1B 10
A
1238-133S
R-HPF
2.50
5
35 240 1.8
4.6
n/a
n/a
230
S250230AC4M
CWA
280
1.38 188
5
8 PC2 1.78 3.58 40 300 n/a
n/a 2.01x3.01
3.9 10.3 HPS400-3A 3
B
(1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP (continued)
230
S400230AC4M
CWA
465
2.26 190
8
10 PC2 2.5 4.3 64 300 n/a
n/a 1.91x2.91
3.1 15.5 HPS400-3A 3
D
(1) 1000 WATT S52 HIGH PRESSURE SODIUM LAMP
230
S1000230AC5M
CWA
1100
5.44 405
15
39 PC3 4.0 5.8 36 540 n/a
n/a 1.96x3.65
4.25 25.5 HPS1000-4B 10
D
HID
CORE & COIL 50 HERTZ
See page 5-37 for Reference Drawings and
Wiring Diagrams.
PAGE 5-36
HID CORE & COIL BALLASTS
50 HZ
50 HERTZ
DESCRIPTION
2.625"
SUFFIX *
0.438"
For Ballast Only
.199" Dia Thru
For0.594"
Capacitor Only (see
pg. 5-5,4 Holes
5-6)
.250" Dia Thru
0.438"
B
A
2.188"
2 Holes
REFERENCE DRAWING PC1
000
A
500B
REFERENCE DRAWING 4
0.656"
.218" Dia Thru
4 Holes
0.199 Dia Thru
0.437"
4 Holes
A
A
B
MAX
.250" Dia Thru
2 Holes
3.937"
3.500"
0.250 Dia Thru
2 Holes
B
A
B
0.843"
0.812"
2.812˝
2.937"
2.437"
2.438˝
3.500"
3.938"
Bracket
To Lamp Shell
e)
347V
277V
A
B
2 Holes Cleared
for #10 Thru-Bolts
120V
3.875˝
4
4.750"
(Blue)
1
3
.250" Dia Thru
2 Holes
A
B
STARTER
2
Four 0.250"
Male Quick
Connect
Terminals
To Lamp Shell
(Yellow)
1.937"
0.625"
.250" Dia Thru
8 Holes
Lamp Eyelet
3
Com
3.875"
4.250"
4.375"
4.250˝
4.375˝ 4.750˝
To Lamp Shell
Com
(Yellow)
3
A
B
MAX
2
3.875"
4.250" 1.937"
4 Holes Cleared
for #10 Thru-Bolts
(Black)
Cap
Cap
Four 0.250"
Male Quick
Connect
Terminals
2
Reference Drawing
4
3
REFERENCE DRAWING
PC2
(Yellow)
(Black)
Cap
Cap
V
3.125"
3.750"
Reference Drawing
BRef. Dwg.
L
W
M
S
1
4.00” 0.75” 3.60” 0.25”
2, 3, 4
5.25” 1.75”
4.60” 0.25”
277V
0.637"
PC1
5.25” 1.25” 4.60” 0.25”
0.637"
Lamp
Eyelet
LampDia
Eyelet
240V
.250" Dia Thru
.250"
Thru
4 Holes (Blue)
PC2 A
7.75”
1.25” 5.75” 0.25”
8 (Blue)
Holes
B
3
3
1
1
208V
3
3
.250" Dia Thru
PC3
7.75” 2.75” 6.10” 0.25” .250" Dia Thru
2 Holes
2 Holes
120V
STARTER
See
p. 5-8 for adjustable mounting brackets and detailed bracket drawings.
STARTER
(White)
V
S
M Reference Drawing
L
2
ference Drawing
1-A
3.125"
.199" Dia Thru
4 Holes
Cap
W
2.500"
Four 0.250" Male
Quick Connect
Blade Terminals
3.500˝ 3.938˝
Cap
3" Dia Thru
4 Holes
2.437"
1.218"
2.812"
(Black)
1.218"
(Yellow)
2.812"
3.875"
4.375"
REFERENCE DRAWING PC3
5.750"
5.375"
4.250" 1.937"
4a
4.375"
5.375"
5.750"
0.250 Dia Thru
8 Holes
Reference Drawing
6
Com
White)
(Yellow)
Line
Red to Lamp Eyelet
Red to Lamp Eyelet
0.250 Dia Thru
2 Holes
1
3
3
3
0.625"
.250" Dia Thru
8 Holes
STARTER
0.687"
.218" Dia Thru
4 Holes
Com
(White)
or (Yellow)
B
2A
.250" Dia Thru
2 Holes
1.062"
To Lamp Shell
7
2.750"
3.437"
Com
(White)
or (Yellow)
3.437"
4.125"
B
2
3.875˝
Red
Lamp Shell
B
8
3.875"
1.937"
4.375"
4.250" 1.937"
5.375"
4.375"
4.750"
Wiring Diagram 10
240V
Lamp Eyelet
(Blue)
Lamp Eyelet
120V
A
.250" Dia Thru
2 Holes
4.375˝
5.375˝ 5.750˝
5.750"
Wiring
Diagram 1
277V
Reference
Drawing
208V
14
0.625"
.250" Dia Thru
4 Holes
STARTER
A
Cap
(White)
3.875"
4.250"
1
3
4.250˝
3.437"
WIRING DIAGRAMS
Reference Drawing
8
B
MAX
(Red)
3
)
wn
o
(Br
1
d)
(Re
3
STARTER
Cap Cap
(Red) (Red)
3
Reference Drawing
15
Reference Drawing
16
1
3
STARTER
Line
2
e
(Y
Com
Com
(Yellow)
(Yellow)
Wiring Diagram 8
Com
Com
(White)
(White)
12
Wiring Diagram 14
HID
CORE & COIL 50 HERTZ
)
w
llo
2
Wiring Diagram 39
11
Line
347V
Lamp Eyelet
(Red)
Blue/White
Trace
3
277V
1
3
120V
Cap
STARTER
Cap
IGNITOR
Line
A
Reference Drawing
7
(Blue)
(Red) (Red)
Cap
(Red)
2
Com
(White)
Com
(White)
15
Com
(White)
Yellow/Red
Trace
Cap
(Red)
Com
(White)
16
PAGE 5-37
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
MH
35-400
WATT
HID
F-CAN
F-CAN BALLASTS
• 60 Hz
• Minimum Starting
Temperature: -30° C
• CWA and High Power
Factor Designs
METAL HALIDE
Nom
Max
Dimensions
Max Open
Dist Certifications
Input
Catalog
Circuit Input Input Circuit Fuse Wir Overall Case Mtg Total To Sound
Volts
Number
Type Watts Current Voltage Rating Dia Length Length Dim Weight Lamp (ft) Rating UL CSA
(1) 35/39 WATT M130 METAL HALIDE (with built-in ignitor)
120
1120-251A-TC
CWA 55
0.50
225
2
21 9.50
8.35 8.85 3.0
20
B Yes Yes
(1) 50 WATT M110 METAL HALIDE (with built-in ignitor)
120
0.64
3
or 11210-236C-TC
HX-HPF 70
240
20 11.75 10.56 11.14 11.0
20
B Yes Yes
277
0.65
2
(1) 70 WATT M85 METAL HALIDE (with built-in ignitor)
120
2.00
6
or 11210-277C-TC7
HX-HPF 98
250
20 11.75 10.56 11.14 11.0
20
B Yes Yes
277
0.90
3
(1) 70 WATT M98 METAL HALIDE (with built-in ignitor)
120
2.00
6
or 11210-506C-TC22
HX-HPF 90
250
20 11.75 10.56 11.14 11.0
20
B Yes Yes
277
0.90
3
120
2.00
6
or 11210-554C-TC
HX-HPF 90
250
20 11.75 10.56 11.14 11.0
20
B
No Yes
347
0.80
3
(1) 100 WATT M90 METAL HALIDE (with built-in ignitor)
120
2.20
8
or 11210-239C-TC
HX-HPF 125
250
20 11.75 10.56 11.14 11.0
20
B Yes Yes
277
1.00
4
120
2.20
8
or 11210-606C-TC
HX-HPF 125
250
20 11.75 10.56 11.14 11.0
20
B
No Yes
347
0.70
2
(1) 150 WATT M81 METAL HALIDE (with built-in ignitor)
120
3.70
10
or 11210-242C-TC
HX-HPF 185
260
20 14.31 13.19 13.75 14.0
20
B Yes Yes
277
1.60
5
(1) 150 WATT M102 METAL HALIDE (with built-in ignitor)
120
3.70
10
or 11210-539C-TC
HX-HPF 185
260
20 14.31 13.19 13.75 14.0
20
B Yes Yes
277
1.60
4
(1) 175 WATT M57 METAL HALIDE LAMP
120
1.75
5
or
20 14.32 13.19 13.75 14.0
CWA 205
300
*
B
Yes Yes
1110-245SC-TC
0.75
3
277
120
1.75
5
or
20 11.75 10.55 11.10 14.0
CWA 205
300
*
B
Yes Yes
1110-564C-TC
0.62
2
347
(1) 250 WATT M58 METAL HALIDE LAMP
120
2.50
8
or
20 16.75 15.57 16.13 17.5
CWA 295
280
*
C
Yes Yes
1110-246C-TC 8c
1.10
4
277
120
2.50
8
or
CWA 300
300
22 11.75 10.55 11.10 11.0
*
B
Yes Yes
1111-246C-TC 23
1.10
4
277
120
2.50
8
or
20 16.65 15.55 16.10 17.5
CWA 295
285
*
C
Yes Yes
1110-566C-TC
0.95
3
347
(1) 400 WATT M59 METAL HALIDE LAMP
120
3.90
10
or
20 19.25 18.06 18.63 23.0
CWA 455
300
*
C
Yes Yes
1110-247SC-TC
1.70
5
277
120
3.90
10
or 1111-247SC-TC 23
CWA 460
300
22 14.31 13.19 13.75 14.0
*
B
Yes Yes
1.70
5
277
120
3.90
10
or
20 19.25 18.05 18.60 23.0
CWA 460
300
*
C
Yes Yes
1110-568C-TC
1.30
5
347
This ballast may also be used with (1) 70 watt S88
High Pressure Sodium lamp.
7
M98 Designates Venture Lighting catalog numbers
MH70/4/MED, C/4/MED or MS70/C/84/MED/W
22
See page 5-40 for Reference Drawings and
Wiring Diagrams.
This ballast can be used with a MH200 ignitor to operate
(1) 250 watt M103 lamp. Consult Universal for instructions.
8c
23
Two of these ballasts are required to operate the lamp.
Electrical data is for two ballasts, except for “Sound Rating,”
which is for each ballast
* Refer to Page 5-5.
PAGE 5-38
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
F-CAN BALLASTS
HIGH PRESSUE SODIUM
HPS
35-250
• 60 Hz
• Minimum Starting
Temperature: -40° C
• CWA and High Power
Factor Designs
WATT
Nom
Max
Dimensions
Max Open
Dist Certifications
Input
Catalog
Circuit Input Input Circuit Fuse Wir Overall Case Mtg Total To Sound
Volts
Number
Type Watts Current Voltage Rating Dia Length Length Dim Weight Lamp (ft) Rating UL CSA
(1) 35 WATT S76 HIGH PRESSURE SODIUM (with built-in starter)
120
0.80
5
or 12210-261C-TC
20 11.75 10.55 11.10 9.0
HX-HPF 55
120
10
B
Yes Yes
0.35
2
277
(1) 50 WATT S68 HIGH PRESSURE SODIUM (with built-in starter)
120
1.40
5
or 12210-236C-TC
20 11.75 10.55 11.10 9.0
HX-HPF 75
120
10
B
Yes Yes
0.60
2
277
(1) 70 WATT S62 HIGH PRESSURE SODIUM (with built-in starter)
120
1.60
5
or 12210-237C-TC
20 11.75 10.56 11.14 9.15
HX-HPF 97
140
10
B
Yes Yes
0.70
2
277
120
1.69
5
or 12210-552C-TC
20 11.75 10.55 11.10 9.2
HX-HPF 109
145
10
B
Yes Yes
0.63
2
347
(1) 100 WATT S54 HIGH PRESSURE SODIUM (with built-in starter)
120
2.10
6
or 12210-239C-TC
20 11.75 10.55 11.10 10.4
HX-HPF 125
130
10
B
Yes Yes
1.00
3
277
120
2.10
6
or 12210-606C-TC
20 11.75 10.55 11.10 10.4
HX-HPF 126
165
10
B
Yes Yes
0.90
3
347
(1) 150 WATT S55 HIGH PRESSURE SODIUM (with built-in starter)
120
2.80
8
or 12210-241C-TC
20 14.30 13.15 13.75 14.1
HX-HPF 185
120
10
B
Yes Yes
1.20
4
277
120
2.80
8
or 12210-602C-TC
20 14.30 13.15 13.75 14.1
HX-HPF 185
120
10
B
Yes Yes
1.03
3
347
See page 5-40 for Reference Drawings and
Wiring Diagrams.
HID
F-CAN
PAGE 5-39
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Insulate Unused Input
Lead for 300 Volts.
White or
Yellow
Wiring Diagram
36
277V Black
or 120V Black/Yellow
F-CAN
277V or 347V Black
or 120V
Black/Yellow
Wiring Diagram
B
34
A
B
A
L
L
A
S
T
BALLAST
Red
Black
White
1.000" 2.000"
Line
Insulate Unused Input
Lead for 300 Volts.
L
L
A
S
T
0.250" Dia.
Red
Red
White
4.000"
4.500"
277V
White or
Yellow
B
A
L
L
A
S
T
Wiring Diagram
35
Separately Insulate Unused Input
Lead for 300 Volts
Wiring Diagram
HID CORE & COIL BALLASTS
36
Red
F-CAN
Black or
Yellow
0.406"
Black
or 120V
0.562"
0.250" Black/Yellow
Dia.
Wiring Diagram
34
Separately Insulate Unused Input
1.000"
Lead for 3002.000"
Volts
Wiring Diagram
35
Wiring
Diagram
Mounting
Bracket Assemblies
4.500"
0.406"
4.000"
36
F-CAN BALLASTS OPTIONAL ACCESSORIES
Mounting Bracket Assemblies
Splice Box
Mounting Bracket Assemblies
Tee-Pee Lead
Wire Covers
1.437"
1.500"
2.562" 2.000"
0.250" Dia.
0.562"
1.750"
0.218" Dia.
1.000" 2.000"
2.531"
1.437"
0.406"
4.000"
4.500"
Tee-Pee Lead Wire Covers
1.500"
2.562" 2.000"
0.562"
Embossed Dimples
2 Places
2.000"
3.000"
1.750"
2.812"
0.850" Dia.
Knockouts
5 Places
0.218" Dia.
Catalog Number
2-BMB-1.
Mounting Bracket Assemblies
Catalog NumberTee-Pee
TP5. Ref.part
Lead #001-2013.
Wire Covers
Available for the remote installation of ballasts. Each
assembly consists of two (2) mounting brackets, four (4)
screws, four (4) washers and four (4) nuts.
For use where ballast is attached to the surface of an
enclosure or raceway.
Embossed Dimples
2 Places
1.437"
1.500"
2.562" 2.000"
2.531"
0.297" Dia.
Mounting Holes
2 Places
Box
Catalog Number SB-4. Splice
Ref. part
#001-2009
2.000"
3.000"
2.812"
0.850" Dia.
Knockouts
5 Places
For use with all F-Can Ballasts. It is easily installed on
0.297" Dia.
the anchor bracket provided on each
F-Can ballast. It
Mounting Holes
contains five (5) 7/8” diameter knockouts.
2 Places
Splice Box
1.750"
0.218" Dia.
2.531"
REFERENCE
DRAWING
Tee-Pee Lead
Wire Covers
FOR F-CAN
e
as
Embossed Dimples
2 Places
2.000"
3.000"
0.850" Dia.
Knockouts
5 Places
0.297" Dia.
Mounting Holes
2 Places
th
ng
Le
2.812"
Height
C
Width
Splice Box
g
tin ngth
un
e
Mo rall L
e
Ov
Hole
Mounting
Width
WIRING DIAGRAMS
B
A
Wiring Diagram 20 L
L
A
S
T
Black
L
L
A
S
T
Red
Line
HID
F-CAN
B
A
L
L
A
S
T
Red
White
White or
Yellow
120V Black
277V Black
or 120V Black/Yellow
Wiring Diagram
35
Red
White
LAST
B
A
Wiring Diagram
21
Wiring Diagram 22
Black or
Yellow
Red
Separately
Neutral toInsulate
Lamp ShellUnused Input
Lead for 300 Volts
Wiring Diagram
36
1.000" 2.000"
0.406"
0.562"
PAGE 5-40
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
STANDARD IGNITORS • INSTANT RESTRIKE IGNITORS •
LONG DISTANCE IGNITORS • AUTOMATIC SHUTOFF
IGNITORS • SHUTOFF DEVICES
Catalog Number
IGNITORS
Description
Reference Drawing Number
--STANDARD IGNITORS
(See pg. 5-43)
PULSE START METAL HALIDE
MH 70-3B 13
MH 100-3A
MH 150-1A
MH 200-1B 13
MH 350-1A
P 750-1B13
HPS 1000-4B13
HIGH PRESSURE SODIUM
HPS 150-3A
HPS 400-3A
HPS 450-1B 13
HPS 460-1B 13
HPS 600-1B
HPS 610-1B
HPS 1000-4B 13
HPS 1000-6B 13
For double-ended MH lamps with HX-HPF ballasts: 70 watt (M85), 100 watt (M91), and 150 watt (M81)
27
For MH lamps with HX-HPF ballasts: 35/39w(M130), 50w(M110), 70w(M98), 100w(M90/M140), and 150w(M102/M142) 25
For 150 watt (M102/M142) lamp with CWA ballast
28
For double-ended MH 250 watt (M80) lamp
28
For MH lamps with CWA ballasts: 175 watt (M152/M137), 200 watt (M136), 250 watt (M153/M138),
320 watt (M154/M132), 350 watt (M131), 400 watt (M155/M135), and 450 watt (M144)
24
For 750 watt (M149) MH lamp
28
For MH lamps: 875 watt (M166) and 1000 watt (M141). It is also used for 1000W HPS lamps
28
For HPS lamps of 150 watt or less with HX-HPF ballast, except 150 watt S56 lamp
For HPS lamps from 200 to 400 watts and 150 watt S56 lamp with CWA ballasts
For 150 watt S56, 200, 250 or 400 watt lamps with 240 volt/60 Hz reactor ballasts. With attached mounting bracket.
For 200, 250 and 400 watt lamps with HX-HPF ballasts and 50 Hz reactor ballasts. With attached mounting bracket.
For 600 watt lamps.
For 600 watt lamps.
For 1000 watt HPS and Pulse Start Metal Halide lamps. With attached mounting bracket.
Obsolete
24
25
28
28
28
27
27
27
PLUG REPLACEABLE IGNITORS
PULSE START METAL HALIDE
MH 150-G15
MH 350-G05
HIGH PRESSURE SODIUM
HPS 150-G01
HPS 400-G05
For MH lamps with HX-HPF ballasts: 35/39 watt (M130), 50 watt (M110), 70 watt (M98), 100 watt (M90/M140),
and 150 watt (M102/M142)
32
For MH lamps with CWA ballasts: 175 watt (M152/M137), 200 watt (M136), 250 watt (M153/M138),
320 watt (M154/M132), 350 watt (M131), 400 watt (M155/M135), and 450 watt (M144)
32
For HPS lamps of 150 watt or less with HX-HPF ballast, except 150 watt S56 lamp
For HPS lamps from 200 to 400 watts and 150 watt S56 lamp with CWA ballasts
32
32
INSTANT RESTRIKE IGNITORS
HIGH PRESSURE SODIUM
HPS 150-5B 13
Instant Restrike Ignitor — for lamps of 150 watts or less except 150 watt S56. Ignitor has attached mounting bracket.
30
LONG DISTANCE IGNITORS
PULSE START METAL HALIDE
MH 100-5A
MH 100-5A
MH UNV-5B
HIGH PRESSURE SODIUM
HPS 150-4A
HPS 400-4A
HPS 1000-5B
For MH lamps from 35 to 50 watts. Max Ballast to Lamp Distance ( ~ 20’)
For MH lamps from 70 to 150 watts. Max Ballast to Lamp Distance ( ~ 30’)
For MH lamps from 35 to 450 watts. Ignitor incorporates automatic resetting thermal protection.
Max Ballast to Lamp Distance ( ~ 50’)
25
25
25
For HPS lamps of 150 watt or less, excerpt 150 watt S56 lamp. Max Ballast to Lamp Distance ( ~ 20’)
24
For HPS lamps from 200 to 400 watts and 150 watt S56 lamp. Max Ballast to Lamp Distance ( ~ 25’)
25
For 1000 watt HPS lamps. Ignitor incorporates automatic resetting thermal protection. Max Ballast to Lamp Distance ( ~ 50’) 25
AUTOMATIC SHUTOFF IGNITORS
PULSE START METAL HALIDE
MH 150-35B
MH 350-15B 13
13
P 750-15B 13
HPS 1000-55B 13
HIGH PRESSURE SODIUM
HPS 150-45B 13
HPS 400-45B 13
HPS 1000-55B 13
For MH lamps: 35/39 watt (M130), 50 watt (M110), 70 watt (M98), 100 watt (M90/M140), and 150 watt (M102/M142).
With attached mounting bracket
For 150 watt M81 lamp with CWA ballasts. With attached mounting bracket.
For MH lamps: 175 watt (M152/M137), 200 watt (M136), 250 watt (M153/M138), 320 watt (M154/M132),
350 watt (M131), 400 watt (M155/M135), and 450 watt (M144)
For 750 watt (M149) MH lamp
For MH lamps: 875 watt (M166) and 1000 watt (M141). It is also used for 1000W HPS lamps
For lamps of 150 watts or less except 150 watt S56. With attached mounting bracket.
For lamps from 200 to 400 watts and 150 watt S56 with constant wattage autotransformer ballasts.
With attached mounting bracket.
For 1000 watt HPS and Pulse Start Metal Halide lamps. With attached mounting bracket.
AUTOMATIC SHUTOFF DEVICES
In addition to one-piece shutoff ignitors, automatic shutoff devices are available as separate components for use with the ignitors below.
SA-55
SA-100
SA-250
13
HPS 150-3A, HPS 150-5B
MH70-3B, MH100-3A, MH150-1A, MH350-1A, HPS150-4A, HPS400-3A, HPS600-1B
HPS1000-4B ignitor, only with 1000 watt HPS ballasts
28
31
31
31
31
28
28
31
25
25
33
May also be available without attached mounting bracket. Substitute “A” suffix for “B” suffix when ordering. Minimum quantities may apply.
PAGE 5-41
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
IGNITORS
MH 100-35B 13
IGNITORS
IGNITORS
Lamp
Watts
ANSI
Code
Circuit
Type
Standard
Ignitors
Auto
Shutoff
Instant
Restrike
Long Distance
Ignitors
Lamp
Watts
HPS 150-45B
HPS 150-45B
HPS 150-45B
HPS 150-45B
HPS 150-45B
HPS 400-45B
HPS 400-45B
HPS 400-45B
HPS 400-45B
HPS 400-45B
HPS 400-45B
HPS 400-45B
—
—
HPS 1000-55B
HPS 150-5B
HPS 150-5B
HPS 150-5B
HPS 150-5B
HPS 150-5B
—
—
—
—
—
—
—
—
—
—
HPS 150-4A
HPS 150-4A
HPS 150-4A
HPS 150-4A
HPS 150-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
—
—
—
35
50
70
70
100
100
100
150
150
150
350
350
HIGH PRESSURE SODIUM IGNITORS
HID
IGNITORS
35
50
70
100
150
150
250
250
250
400
400
400
600
600
1000
S76
S68
S62
S54
S55
S56
S50
S50
S50
S51
S51
S51
S106
S106
S52
Reactor
Reactor, HX
Reactor, HX
Reactor, HX
Reactor, HX
CWA
Reactor
CWA
HX
Reactor
CWA
HX
CWA
Reactor
CWA
HPS 150-3A
HPS 150-3A
HPS 150-3A
HPS 150-3A
HPS 150-3A
HPS 400-3A
HPS 450-1B
HPS 400-3A
HPS 460-1B
HPS 450-1B
HPS 400-3A
HPS 460-1B
HPS 600-1B
HPS 610-1B
HPS 1000-4B
ANSI
Code
Circuit
Type
Standard
Ignitors
Auto
Shutoff
Long Distance
Ignitors
MH 100-3A
MH 100-3A
MH 70-3B
MH 100-3A
MH 100-3A
MH 100-3A
MH 70-3B
MH 70-3B
MH 150-35B
MH 100-3A
MH 70-3B
MH 70-3B
—
—
MH 70-35B
MH 100-35B
MH 100-35B
MH 100-35B
—
—
MH 150-35B
MH 100-35B
—
—
MH 100-5A
MH 100-5A
MH 100-5A
MH 100-5A
MH 100-5A
MH 100-5A
—
—
—
MH 100-5A
—
—
METAL HALIDE IGNITORS
M130
M110
M85
M98
M90
M90
M91
M81
M81
M102
M131
M131
Reactor
HX
HX
HX
Reactor
CWA
HX
HX
CWA
HX
Reactor
HX
STANDARD IGNITORS
LONG DISTANCE IGNITORS
Standard Ignitors are supplied with all Universal High
Pressure Sodium and Metal Halide ballasts requiring ignitors.
These ballasts are supplied with an appropriate external ignitor
unless the ignitor is permanently attached to or built into the
ballast.
Long Distance Ignitors are used in situations where a ignitor
must be mounted further from the lamp than is recommended
for a standard ignitor. The maximum lamp to ignitor distance
for these ignitors is 50 feet, which may vary depending on the
type of lamp, ballast, fixture, and wiring.
INSTANT RESTRIKE IGNITORS
AUTOMATIC SHUTOFF IGNITORS
An Instant Restrike Ignitor generates multiple pulses to
restrike a lamp arc after a brief power interruption has
extinguished it, without the typical 3-minute cool-down time.
A Standard Ignitor cannot restrike an arc until the lamp has
had time to sufficiently cool. Even though an Instant Restrike
Ignitor can reinitiate the lamp arc immediately upon restoration
of power, the lamp is still subject to warmup. The following
chart is based on an S55 lamp.
In the event of a lamp failure, a Standard Ignitor will continue
to pulse, trying to start the lamp. This may reduce the life of
the ignitor. An Automatic Shutoff Ignitor will apply pulses for
10 to 12 minutes and then deactivate if a lamp arc cannot be
initiated. Resetting the ignitor is accomplished by momentarily
interrupting the power to the ballast. For this reason, these
ignitors are not recommended for use on unswitched circuits.
Time Lamp Is
Extinguished
Restrike
Time
1 second
5 seconds
15 seconds
30 seconds
1 minute
Cold Start
2 seconds
Instant
Instant
Instant
Instant
Instant
Light Output
On Reignition
87%
83%
76%
62%
46%
36%
SHUTOFF DEVICES
Lamp Warmup
Time
Ignitor Accessory (IA) devices can be used to convert
a Standard Ignitor into an Automatic Shutoff Ignitor. Simply
match the Shutoff Device catalog number on page 5-62 with
the Standard Ignitor that is supplied with the ballast. Using the
IA device with the Standard Ignitor eliminates the need to buy
a separate Automatic Shutoff Ignitor.
35 seconds
70 seconds
130 seconds
190 seconds
255 seconds
360 seconds
TEMPERATURE RATING
PLUG REPACEABLE IGNITORS
Most ignitors are rated for a 105°C maximum case
temperature. Consult ballast specification sheets at
www.unvlt.com for specific details.
Incorporates terminals and a separate mounting base to
simplify construction and replacement.
PAGE 5-42
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
0.750"
2.500"
ng
.219 Dia. Thru
1.250"
REFERENCE DRAWINGS
Starter Reference Drawing
26
All dimensions in decimals.
All lead lengths: 13 inches ±1
Starter Reference Drawing
25
Sta
No. 1 (Red or Blue)
No. 1 (Red or Blue)
No. 3 (Brown)
Ref. Drawing 24
Ref. Drawing 25
No. 3 (Brown)
No. 2 (Yellow)
No. 2 (Yellow)
Mounting
Bracket
No. 1 (Red
or Blue)
No. 1 (Red or Blue)
No. 3 (Brown)
No. 3 (Brown)
1.312"
No. 2 (Yellow)
No. 2 (Yellow)
No. 1 (Red or Blue)
No. 1 (Red or Blue)
No. 3 (Brown)
No. 3 (Brown)
No. 2 (Yellow)
No. 2 (Yellow)
Mounting Bracket
1.312"
No. 1.250"
1 (Red or Blue)
No. 3 (Brown)
No. 2 (Yellow)2.031"
ing
ing
n)
2.031"
2.031"
0.875"
0.218"
e Drawing
w)
e/White)
d or Blue)
)wn)
racket
ow)
No. 2 (Yellow)
No. 1 (Red or Blue)
Mounting Bracket
No. 3 (Brown)
No.
2 (Yellow)
1.312"
1.265"
Mounting Bracket
1.265"
0.500"
1.250"0.500"
1.312"
2.031"
0.750"
0.750"
1.250"
.219 Dia. Thru
0.875"
.219 Dia. Thru
2.031"
3.500"
No. 2 (Yellow)
1.250"
Bracket
3.500"
4.312"
4.750"
4.312"
Starter Reference Drawing
29
No. 1 (Red or Blue)
Reference
Drawing
No. 1 (Red
or Blue)
Ref. Drawing Starter
31
No. 3 (Brown)
27
No. 3 (Brown)
1.250"
e Drawing
ce Drawing
low)
ue/White)
e)
Bracket
0.875"
2.531"
3.500"
4.312" 2.031"
0.875" 0.218"
4.750"
0.875"
0.218"
Ballast (Blue/White)
Lamp (Blue)
Mounting Bracket
1.562"
1.500"
0.875"
2.500"
0.218"
0.875"
3.500"
4.312"
4.750"
.218"
No. 1 (Red or Blue)
No. 1 (Red or Blue)
No. 3 (Brown)
No. 3 (Brown)
No. 2 (Yellow)
No. 2 (Yellow)
Mounting Bracket
Mounting Bracket
Ref. Drawing 32
1.312"
1.250"
2.031"
3.500"
4.312"
4.750"
3.500"
4.312"
4.750"
Starter Reference Drawing
30
1.250"
0.875"
0.218"
2.031"
0.875"
0.218"
0.218"
4.750"
Starter
Reference
Drawing
Starter
Reference
Drawing
28
28
Starter Reference Drawing
Starter Reference
Drawing
31
29
Com. (Yellow)
Starter
Reference
Drawing
Starter
Reference
Drawing
29
29
Ballast (Blue/White)
Ballast (Blue/White)
Lamp (Blue)
Lamp (Blue)
Com. (Yellow)
Com. (Yellow)
Mounting Bracket
Mounting Bracket
Com. (Yellow)
Ballast (Blue/White)
Ballast (Blue/White)
Lamp (Blue)
Lamp (Blue)
Mounting Bracket
Ballast
(Blue/White)
Mounting Bracket
Lamp (Blue)
1.562"
1.562"
Com. (Yellow)
1.562"
Mounting Bracket 1.500"
1.500"
1.562"
3.500"
1.531"
3.500"
2.500"
0.875"
1.531"
2.500"
PAGE 5-43
3.750"
1.562"
1.531"
2.531"
0.875"
3.750"
St
Ref. Drawing 33
1.312"
2.031"
0.875"
0.218"
0.218"
HID
IGNITORS
0.218"
3.500"
4.312"
3.750" 4.750"
4.312"
3.500"
4.750"
4.312"
Com. (Yellow)
Starter
Reference
Drawing
Starter
Reference
Drawing
27
27
Mounting Bracket 1.250"
1.562" 1.250"
2.500"
Ref. Drawing 30
.875"
Ballast (Blue/White)
No. 2 (Yellow)
No. 2 (Yellow)
Lamp
(Blue)
Bracket
No. 1Mounting
(Red or Mounting
Blue)
Bracket
Com.
No. 3(Yellow)
(Brown)
1.312"
1.312"
Mounting
Bracket
No. 2 (Yellow)
2.031"
0.218"
2.057"
St
2.031"
0.875"
1.25"
3.500"
4.312"
4.750"
3.46"
4.312"
4.750"
4.750"
1.312"
1.531"
0.875"
0.218"
0.218"
Starter Reference Drawing
28
1.250"
2.031"
1.312"
0.218"
Starter
Drawing
0.875"
4.750" Reference
Starter
Reference
Drawing
3.500"
26
26
4.312"
Bracket
2.031"
0.875"
No. 1 (Red or Blue)
No. 1 (Red or Blue)
No. 3 (Brown)
No. 3 (Brown)
No. 2 (Yellow)
No. 2 (Yellow)
120V (Black/Yellow)
Mounting Bracket
Mounting Bracket
No. 1 (Blue)
1.312"
1.312"
No. 3 (Brown)
Ref. Drawing 28
0.218"
wing
3.500"
4.312"
4.750"
Starter
Reference
Drawing
Starter
Reference
Drawing
25 25
No. 3 (Brown)
racket
0.875"
1.250"
1.250"
Starter
Reference
Drawing
Starter
Reference
Drawing
Starter Reference
24 24 Drawing
27
Starter Reference Drawing
No. 1 (Red or Blue)
25
Ref. Drawing 27
w)
2.500" 1.250"
2.500"
0.218"
2.500"
or Blue)
1.250"
0.875"
1.250"
1.250"
3.500" 2.000"
2.000"
4.312"
4.750"
IGNITORS
0.875"
2.531"
0.875"
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
Notes
PAGE 5-44
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
eHID
Less energy. Enhanced performances.
Experience significant energy savings and increased lumen output vs. halogen lamps with Electronic
High Intensity Discharge (HID) ballasts from Universal Lighting Technologies. Vossloh-Schwabe (VS), also
a Panasonic Lighting Company, recently merged its US operation into Universal. This merger combines
Vossloh’s market leading high quality electronic HID product line with Universal’s extensive offering.
There are numerous advantages of using VS electronic HID ballasts. Operating HID lamps used in HID
lighting systems with electronic ballasts greatly increases system efficiency in comparison with magnetic
ballasts. These ballasts are designed to provide optimal lamp performance
and maximum energy savings. With enhanced capabilities to downsize
the form factor of luminaire housings and reduce wiring costs, VS electronic HID ballasts lead the way to electronic solutions for HID lighting. Microprocessor controlled intelligence offers superior lamp performance and the
flexibility for proprietary value-added functions. VS electronic HID ballasts
cover your HID needs with products for Metal Halide Lamps ranging from
20 Watts to 250 Watts.
VS electronic HID ballasts continuously monitors lamp characteristics
during operation and adjusts the lamp current to optimize performance.
This guarantees controlled operation in all modes of operation. The lamp
color temperature is also stabilized by using VS electronic HID ballasts
due to its relatively constant output power characteristics in addition to
producing flicker free lighting that usually occurs at the end of the discharge lamp’s service life. The
technology enhancements of VS electronic HID ballasts, allowing very small form factors and light weight
designs, has enabled new, innovative luminaire designs.
ELECTRONIC HID
Universal Lighting Technologies is a subsidiary of
Panasonic Electric Works Co., Ltd., a member of the Panasonic Group
Product Overview
Micro Series: The introduction of the smallest eHID ballasts in the market was
coordinated with the launch of the new miniaturized capsule MH lamps
enabling the ultimate luminaire design flexibility. Extremely compact
and aesthetically pleasing, luminaire designs are approaching
the form factor and size of low voltage halogen systems.
Mini Ballast Series: Two ideal form factors that are used
in millions of HID track light luminaires characterize the mini series
of eHID ballasts. The mini-slim and mini-square units revolutionized
track lighting by allowing significantly smaller and greater
variety of luminaire designs while providing
energy savings of 60-70%
versus halogen systems.
ELECTRONIC HID
Standard Case “Valued-added Series”: Millions of recessed,
track-head and specialty luminaires have used the de facto industry
standard enclosure since introduction. The significant energy savings
and enhanced reliability of our ballasts promoted the rapid escalation
of electronically ballasted MH luminaires for almost 15 years. Technological advancements have now allowed the integration of multiple,
value-added functions such as: a powersource for the self-heating
thermal protectors, an electronic 277V step-down transformer, and
an intelligent auxiliary lighting control for back-up lighting during
lamp hot restrike modes. Ideal for new, retrofit and replacement
applications in recessed luminaires.
Features and Benefits:
• Optimum lamp performance
• Rugged, compact and lightweight design
• High power factor
• Enhanced color and CRI uniformity
• Shut-down protection
• Reduced wiring costs
• Eliminates nuisance lamp cycling at end-of-lamp life (intelligent lamp sensing capabilities)
• Constant lamp power
• Reduced lamp dropouts due to improved line voltage dip withstand
• Quiet operation
• Durable performance for various applications
• Fewer SKUs required in inventory
• Broadens design flexibility for new applications and luminaries
PAGE 6-2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
eHID Product Family
Order code
Part #
Lamp Wattage
Lamp Type
Input Voltage
Mounting
Lead Exit
Dimensions
Wiring
Micro Series
188514
M2012CK-7EUN
20
M/C156
120
No Feet
Side
1
1
188882
M2012CK-7EUN-F
20
M/C156
120
Feet
Side
2
1
1
188883
M2012CK-7EUN-J
20
M/C156
120
Studs
Top
3
188574
M2212CK-7EUN
22
M/C175
120
No Feet
Side
1
1
188884
M2212CK-7EUN-F
22
M/C175
120
Feet
Side
2
1
1
188885
M2212CK-7EUN-J
22
M/C175
120
Studs
Top
3
188635
M3912CK-7EUN
39
M/C130
120
No Feet
Side
4
1
188776
M3912CK-7EUN-F
39
M/C130
120
Feet
Side
2
1
1
188756
M3912CK-7EUN-J
39
M/C130
120
Studs
Top
3
188757
MTm3912CK-7EUN
39Tm
M/C179
120
No Feet
Side
4
1
188777
MTm3912CK-7EUN-F
39Tm
M/C179
120
Feet
Side
2
1
188758
MTm3912CK-7EUN-J
39Tm
M/C179
120
Studs
Top
3
1
Mini-Slim Series
188152
M2012CK-6EUN-F
20
M/C156
120
Feet
Side
5
1
188246
M3912CK-6EUN-F
39
M/C130
120
Feet
Side
5
1
188702
M3927CK-6EUN-F
39
M/C130
277
Feet
Side
6
1
188774
M3927CK-6EUN-J
39
M/C130
277
Studs
Top
7
1
188164
M7012CK-6EUN-F
70
M/C98, M/C139, M/C143
120
Feet
Side
5
1
188703
M7027CK-6EUN-F
70
M/C98, M/C139, M/C143
277
Feet
Side
6
1
188775
M7027CK-6EUN-J
70
M/C98, M/C139, M/C143
277
Studs
Top
7
1
Mini-Square Series
188151
M2012CK-6EU-F
20
M/C156
120
Feet
Side
8
1
188627
M2012CK-6EU-J
20
M/C156
120
Studs
Top
9
1
188701
M2212CK-6EU-J
22
M/C175
120
Studs
Top
9
1
188293
M3912CK-6EU-F
39
M/C130
120
Feet
Side
8
1
1
188512
M3912CK-6EU-J
39
M/C130
120
Studs
Top
9
188402
M3927CK-6EU-F
39
M/C130
277
Feet
Side
10
1
188551
M3927CK-6EU-J
39
M/C130
277
Studs
Top
9
1
188377
JM7012CK-6EU-F
70
M/C98, M/C139, M/C143
120
Feet
Side
11
1
188628
M7012CK-6EU-J
70
M/C98, M/C139, M/C143
120
Studs
Top
9
1
188895
M3912-27CK-6EU-F
39
M/C130
120-277
Feet
Side
10
1
188896
M3912-27CK-6EU-J
39
M/C130
120-277
Studs
Top
9
1
188897
M3912/27CK-6EU-JT3
39
M/C130
120/277
Studs
Top
9
2a,2b,2c
188901
M2012-27CK-6EU-F
20
M/C156
120-277
Feet
Side
10
1
188902
M2012-27CK-6EU-J
20
M/C156
120-277
Studs
Top
9
1
188903
M2012/27CK-6EU-JT3
20
M/C156
120/277
Studs
Top
9
2a,2b,2c
188939
M7012-27CK-6EU-F
70
M/C198,M/C139,M/C143
120-277
Feet
Side
10
1
188940
M7012-27CK-6EU-J
70
M/C198,M/C139,M/C143
120-277
Studs
Top
9
1
188941
M7012/27CK-6EU-JT3
70
M/C198,M/C139,M/C143
120/277
Studs
Top
9
2a,2b,2c
Standard Series
188610
M2012-27CK-5EU-F
20
M/C156
120-277
Feet
Side
12
1
188611
M2012/27CK-5EU-JT3
20
M/C156
120/277
Studs
Top
13
2a, 2b, 2c
188156
M3912-27CK-5EU
39
M/C130
120-277
No Feet
Side
14
1
188157
M3912-27CK-5EU-F
39
M/C130
120-277
Feet
Side
12
1
188301
M3912-27CK-5EU-J
39
M/C130
120-277
Studs
Top
13
1
188629
M3912/27CK-5EU-JT3
39
M/C130
120/277
Studs
Top
13
2a, 2b, 2c
188630
M3912/27CK-5EU-JA3
39
M/C130
120/277
Studs
Top
13
3a, 3b, 3c
188612
M5012-27CK-5EU-F
50
M148 or M110
120-277
Feet
Side
12
1
188613
M5012/27CK-5EU-JT3
50
M148 or M110
120/277
Studs
Top
13
2a, 2b, 2c
M7012-27CK-5EU
70
M/C98, M/C139, M/C143
120-277
No Feet
Side
14
1
M7012-27CK-5EU-F
70
M/C98, M/C139, M/C143
120-277
Feet
Side
12
1
188167
M7012-27CK-5EU-J
70
M/C98, M/C139, M/C143
120-277
Studs
Top
13
1
188631
M7012/27CK-5EU-JT3
70
M/C98, M/C139, M/C143
120/277
Studs
Top
13
2a, 2b, 2c
188632
M7012/27CK-5EU-JA3
70
M/C98, M/C139, M/C143
120/277
Studs
Top
13
3a, 3b, 3c
188633
M10012/27CK-5EU-JT3
100
M/C90, M/C140 and M/C164
120/277
Studs
Top
13
2a, 2b, 2c
188168
M10012-27CK-5EU
100
M/C90, M/C140 and M/C164
120-277
No Feet
Side
14
1
188169
M10012-27CK-5EU-F
100
M/C90, M/C140 and M/C164
120-277
Feet
Side
12
1
188302
M10012-27CK-5EU-J
100
M/C90, M/C140 and M/C164
120-277
Studs
Top
13
1
188634
M10012/27CK-5EU-JA3
100
M/C90, M/C140 and M/C164
120/277
Studs
Top
13
3a, 3b, 3c
188638
M15012-27CK-5EU-F
150
M/C102/E and M/C142/E
120-277
Feet
Side
12
1
188639
M15012-27CK-5EU-J
150
M/C102/E and M/C142/E
120-277
Studs
Top
13
1
C183
208-277
Feet
Side
17
4a, 4b
M80/M168
208-277
Feet
Side
17
4a, 4b
Mid Wattage
188909
M21020-27CK-2EUN-F
210
188911
M25020-27CK-2EUN-F
250 (100V)
PAGE 6-3
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
ELECTRONIC HID
188165
188166
Wiring Diagrams
1
N
WHITE
120V
RED
L
1
BLACK
BLUE
GREEN
120/277V with IDTP Tap
2b
WIRING (with 3-wire 120V IDTP)
WIRING (with 4-wire 120V IDTP)
RP-1B
IDTP 2
black
L
blue
N
WHITE
black
120/277
white
120/277
N
WHITE
PURPLE
blue
white
L
RP-5A
IDTP 2
red
2a
PURPLE
BLACK
BLACK
GREEN
GREEN
RED
RED
1
BLUE
1
BLUE
2c
WIRING (with 3-wire 277V IDTP)
RP-4A
IDTP 2
L
277
N
red
white
black
WHITE
PURPLE
BLACK
GREEN
RED
1
BLUE
120/277V with Auxiliary Control + IDTP Tap
Wiring & Dimensions Diagrams (shown in millimeters and inches)
3b
WIRING (with 3-wire 120V IDTP)
WIRING (with 4-wire 120V IDTP)
RP-1B
IDTP 2
N
WHITE
HALOGEN LAMP
<150W
L
blue
white
black
120/277
black
120/277
N
ORANGE
PURPLE
WHITE
BLACK
GREEN
GREEN
RED
RED
1
Connect red lead to center contact on Edison base lampholders
2
IDTP - Insulation Detector Thermal Protector
1
BLUE
Notes for Wiring Diagram
1
blue
ORANGE
PURPLE
BLACK
BLUE
ELECTRONIC HID
HALOGEN LAMP
<150W
red
L
RP-5A
IDTP 2
white
3a
3c
WIRING (with 3-wire 277V IDTP)
RP-4A
IDTP 2
L
black
277
N
WHITE
HALOGEN LAMP
<150W
red
white
ORANGE
PURPLE
BLACK
GREEN
RED
1
BLUE
PAGE 6-4
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Wiring
Dimming Ballasts
4a
4b
WIRING (For Fixed Output)
WIRING (For Dimming Control)
RED
RED
BLUE
BLUE
GREEN
GREEN
BLACK
BLACK
WHITE
WHITE
GREY (+)
GREY (+)
PINK (+)
PINK (+)
0 - 10V
DIMMER
Dimensions
1
2
33.5/1.32
29.7/1.17
33.0/1.30
97.7/3.85
76.0/2.99
Temp. Testpoint
31.0/1.22
28.0/1.10
Temp. Testpoint
104.7/4.12
3
4
33.5/1.32
16.7/0.66
33.5/1.35
96.7/3.81
90.7/3.57
Temp. Testpoint
38.1/1.5
Temp. Testpoint
11.8/0.47
8-32 stud
50.8/2.0
PAGE 6-4
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
ELECTRONIC HID
30.1/1.19
Dimensions
5
6
28.6/ 44.2/
1.13 1.74
28.6/ 44.2/
1.13 1.74
133/5.25
133/5.25
140..0/5.51
140.0/5.51
30.0/1.18
30.0/1.18
7
8
44.2/
1.74
64.8/2.55
75.6/2.98
22.1/
0.87
127.8/5.03
50.8/2
86.8/3.42
10.9/0.43
95.1/3.74
39.5/
1.56
Temp. Testpoint
9
30.6/1.21
10
76.2/3.0
64.8/2.55
75.6/2.98
38.1/1.5
86.8/3.42
89.4/3.52
95.1/3.74
50.8/2.0
11.8/0.47
8-32 stud
30.6/1.21
39.7/1.56
ELECTRONIC HID
11
12
64.8/2.55
72.1/
2.84
76.0/2.99
92.0/
3.62
46.0/
1.31
86.8/3.42
133.5/5.26
95.1/3.74
140.0/5.51
39.9/1.57
31.8/1.25
PAGE 6-5
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Dimensions
13
14
92.0/3.62
92.0/
3.62
46.0/1.31
127.5/5.02
8-32 stud
133.5/5.26
50.8/2.0
11.4/0.45
39.9/1.57
39.9/1.57
15
16
92.0/3.62
72.1/
2.84
92.0/
3.62
46.0/
1.31
46.0/1.31
127.5/5.02
8-32 stud
133.5/5.26
50.8/2.0
140.0/5.51
11.4/0.45
39.9/1.57
39.9/1.57
17
72.0/
2.84
92.0/
3.62
46.0/
1.31
202.0/ 7.95
208.0/ 8.19
60.0/2.36
ELECTRONIC HID
PAGE 6-6
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
General:
If the electrical current through an HID lamp is properly stabilized, an HID plasma arc with very high luminous efficiency is created
in the arc tube chamber resulting in a very efficient light source. The internal pressure of the arc tube chamber rises as the arc
tube temperature increases and will attain between 1 and 10 bar; thereby, defining these lamps as high-pressure HID lamps, high
intensity discharge lamps or simply HID lamps. The light output and color rendition of HID lamps vary considerably depending on
the lamp family (mercury, metal halide or sodium lamps).
HID lamps can only be started and operated with ballasts. Ignitors or ignition voltage characteristics are additionally required for
sodium and metal halide lamps. As well as stabilizing the lamp’s operating point, ballasts also influence the lamp’s output and
luminous flux, the system light output, the service life of the lamps as well as the color temperature of the light source.
Electromagnetic or electronic ballasts can be used for HID lamps, but unlike fluorescent lamps, lamp
efficiency is not significantly improved by the use of electronic ballasts. However, electronic ballasts can
lead to a reduction of the inherent losses and thus to an increase in system efficiency. In addition,
electronic ballasts can ensure gentle lamp operation, which may increase lamp’s service life.
Electronic Ballasts for Metal Halide Lamps
Electronic ballasts are designed with all the components required to operate metal halide lamps, including ignition, power factor
correction, and stable normal operation. Furthermore, they safely shutdown lamps at the end of their service life to prevent high
temperatures from being generated in the luminaires that could influence the service life of the luminaire or its components.
Vossloh-Schwabe also provides special electronic ballasts for additional luminaire functions such as heater power for insulation
detection thermal protectors and for switching on of an auxiliary incandescent lamp for the dark phase of an HID lamp during
initial warm-up or during hot-restrike cool-down mode.
Standards/Regulations
ANSI C82.14
Low-Frequency Square Wave Electronic Ballasts for Metal Halide Lamps
UL 1598
Standard for Safety-Luminaires
ANSI C82.77
Harmonic Emission Limits-Related Power Quality Requirements
or Lighting Equipment
ANSI/UL 1029
Standard for Safety-High Intensity HID Lamp Ballasts
ANSI/IEEE C62.41 Surge Voltages in Low Voltage AC Power Circuits
ELECTRONIC HID
US Code of Federal Regulations Title 47 –Telecommunications Part 18– Industrial, Scientific and Medical Devices
PAGE 6-7
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
Technical Specifications:
Operating voltage range
120VAC rated: 120V 277V ±10%
277VAC rated: 277V ±10%
120–277V rated: 108V–305V
120/277V rated: 108V–132V and 249V–305V
Leakage current
≤0.5mA
Hot restrike auxiliary lamp operation
In order to ensure continuous illumination even during the ignition period or in the event of a lamp drop-out due to short term
power outage, an additional incandescent lamp (maximum 150W) can be used on models designated with a JA suffix.
Short circuit issues
The ballast output metal halide lamp leads are basically short-circuit-proof. However, any shorts or connections between those
lamp leads to the ballast case or to safetyneutral (earth ground) will destroy the ballasts. Likewise the metal halide lamp leads
shall not be connected to input power connections nor shall the auxiliary lamp leadsbe shorted together otherwise the ballast’s
circuitry could be damaged or fail.
Provisions in the luminaire design should be implemented to prevent all lead wires but especially lamp leads from being pinched,
damaged, or cut during luminaire assembly, field installation or normal service.
Mechanical Mounting:
Surface
Firm, flat, preferably metal surface required to ensure good heat transfer for long ballast service life and reliability. Avoid mounting
on uneven or protruding surfaces.
Mounting Location
Electronic ballasts must be protected against moisture and heat. Outdoor applications must utilize luminaires with the appropriate
weatherproof ratings depending on location. Most Vossloh-Schwabe electronic ballasts are rated “Outdoor Type 1”.
Fastening
Use mechanical means to ensure ballasts are fixed tightly to flat surfaces. Use appropriately sized screws depending on the
ballast mounting slot size or spring clips to provide interference fit.
If ballast is destined for installation in a luminaire, sufficient heat transfer must be ensured between the electronic ballast and the
luminaire housing. Electronic ballasts should be mounted with the greatest possible clearance from heat sources or lamps.
During operation, the temperature measured at the ballast’s tc point must not exceed the specified maximum value.
PAGE 6-8
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
ELECTRONIC HID
Heat transfer
Application And Operating Information
Technical Specifications:
• Dimensional tolerances:
– Case: ±1mm (±0.039”)
– Standard lead length tolerances: +50mm (+2”) or –30mm (–1”) Micro lead length tolerances: ±15mm (±0.6”)
– Slot width on “F” mounting tabs: 5mm (0.20”); for Mini-Square Size: 4mm (0.157”)
• Remote wiring guidelines:
– Each lamp’s lead wires must be run in a separate conduit from the input power leads to achieve good EMI performance and
maximum remote capabilities. Lamp leads shall not be bundled together, but each set of lamp leads shall be run in its own
conduit.
– Individual lamp lead wires must be used for external fixture wire extensions using wire types SF-2 (equivalent to SEW-2 or
3071) or SFF-2 (equivalent to SEWF-2 or 3070) or alternately, if approved by VS, high voltage luminaire wire with a 18AWG
conductor and a 1000VAC minimum voltage rating. Temperature rating is especially critical if the lamp lead extension wires are
directly connected to lampholder terminals.
– Maximum remote distances:
See individual model specification sheets.
The specified maximum remote distances are based on lamp leads run in a minimum ½” internal diameter conduit, pipe or
flexible conduit. For longer remote distances contact the TES group at Universal Lighting.
– Using service power cords (types SJ, SO, ST, SV etc.) or metal clad cable assemblies for lamp lead extension wire are not
recommended as they are not compatible with the above characteristics, can cause starting problems and shall not be used
unless VS gives written approval.
Insulation clearance
ELECTRONIC HID
Remote mounted ballasts shall be installed per National Electrical Code and local codes while also complying with wiring
methods per Vossloh-Schwabe recommendations. Per UL requirements, thermal insulation shall be a minimum of 3” from
any ballast surface.
PAGE 6-9
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
Safety Functions:
Regulatory approvals
Vossloh-Schwabe electronic HID ballasts are UL listed or UL recognized component and cUL listed for use in Canada.
Shutdown of defective lamps
In the event of a lamp failing to ignite or of a lamp with low or high operating voltages (end of lamp’s service life), the electronic
ballast will switch off after a defined period of time (typically 30 minutes). The ballast will also shut-down if the lamp fails to
achieve symmetrical current operation (rectification) or if lamp leads are shorted to each other. After lamp replacement, the ballast
output can be reset by disconnecting (count to 10) and then reconnecting input power.
Transient input voltage
Electronic ballasts incorporate transient protection that complies with ANSI C62.41 and ANSI C82.14 test procedure and values.
Temperature Protection
To prevent excess temperatures, ballasts contain thermal protection devices or thermal sensing circuitry. A ballast will restart
after it has cooled down, however, it might be necessary to briefly reset the input power after the over-temperature condition is
resolved.
General guidelines
Always disconnect power to the luminaire before installation or service of the ballasts. Install to all provisions of local or National
Electric Codes. The ballast case/green lead must be grounded. Dispose of any replaced ballasts or lamps properly per local
environmental regulations.
Reliability and Service Life:
The electronic ballast service life is inversely proportional to the temperature of its critical internal components. Normal ballast
operation shall have the temperature of the tc point less than the warranted values in the individual specification sheets
Electrical Installation:
3-Phase connection of luminaires with electronic ballasts
Power factor compensation
Luminaires with electronic ballasts do not need power factor compensation, as the typical power factor range of electronic
ballasts is 95 to 99%.
PAGE 6-10
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
ELECTRONIC HID
Prior to operating newly installed lighting systems, please check the ballast’s rated voltage range to ensure it is appropriate
for the job site input power supply voltage. The neutral power supply wire must be connected securely to all luminaires and to
all ballasts. Power supply conductors must only be connected or disconnected when the circuit is not energized. The neutral
conductor must never be disconnected as the first disconnected wire nor individually at the circuit panel, at a distribution wiring
junction box or at the luminaire during energized power supply operation as out-of balance voltage operation can lead to serious
over-voltages and subsequent ballast failures.
Application And Operating Information
Wiring
Wiring between the power supply, electronic ballasts and lamp must comply with the respective circuit diagram.
Note: the ballast (metal) case (using toothed washer) or provided green lead must be connected to safety-neutral (earth ground).
In addition, all metal luminaire parts and metal lamp reflector/housings shall also be connected to earth ground for safety and for
proper lamp starting. Metal halide luminaires must only be fitted with electrical components that are rated to withstand ignition
voltages of 4kV. To ensure compliance with RFI suppression limits, input and output conductors should not be run in the same
conduit as lamp conductors. Conduit size recommendations are stated in the individual ballast specification sheets or
construction notes.
Lamp maintenance notice
To replace end-of-service lamps, turn-off luminaire power, remove and replace lamps then turn-on luminaire power. If power was
not turned off during lamp replacement, the luminaire/ballast-input power must be reset to restart the new lamp. If the lamp or
wiring is defective, the ballast will “shut-down” in 1.5 to 30 minutes depending upon the fault condition.
Supplemental IDTP wiring
The IDTP (insulation detector thermal protector) is required by UL for most recessed luminaires. This fast acting thermal
protector is typically mounted on the same junction box as the electronic ballast. Special “JT” electronic ballasts provide a
separate 120V power supply for the IDTP heater to allow the luminaire to be rated for both 120V and 277V operation. See the
individual ballast specifications for the proper wiring procedures for JT & JA ballasts with this IDTP heater function.
Note: When using JT or JA ballasts on multiple lamp luminaires, only one ballast yellow or purple lead should be connected to the
IDTP heater. All other ballasts’ yellow or purple leads should be capped-off. Operation of JT and JA ballasts on 208V and 240V is
not recommended, as the IDTP may not function properly.
Lamp compatibility
ELECTRONIC HID
Not all HID lamps are compatible with all electronic ballasts. Therefore, consult with Vossloh-Schwabe Technical Support or a
specific lamp company regarding a certain lamp’s compatibility.
PAGE 6-11
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Sign Illuminating
Ballasts
A Complete Range Of Solutions…
From The Name You Trust
Universal Lighting Technologies (“Universal”) is known throughout the sign
business as a company that can set and meet today’s toughest industry
standards. Our high-output ballasts are great for rugged outdoor sign
cabinet applications because they provide ultra-reliable, low-temperature
starting as low as -20° F. All Universal sign ballasts offer Class P thermal
protection. We have three product lines spanning the sign business:
• The UNIVERSAL® USB is a line that offers complete
coverage with 6 units.
•
The UNIVERSAL® MAX-3 ensures that the installer has the
right sign ballast on the truck for every application, from
1-6 lamps, 2-48 feet — replacing up to 100 conventional
ballasts with a maximum of three models.
• Signa® Electronic Sign ballasts are ideal for new sign
installations with minimum wire connections, universal input
voltage, parallel lamp operation, and maximum energy savings.
Universal offers the convenience of one-stop shopping for not just sign ballasts, but compact fluorescent, linear fluorescent, HID, and all your other
ballast needs.
For the unmistakable sign of quality and reliability, turn to Universal.
Universal Lighting Technologies is a subsidiary of
Panasonic Electric Works Co., Ltd., a member of the Panasonic Group
Plastic Sign Ballasts
Universal ® sign ballasts provide ultra-reliable low-temperature starting —
plus Class P thermal protection.
Application And Operating Information
Heat
Ballasts generate heat during normal operation. By design,
fluorescent ballasts should operate so that their maximum
hot-spot case temperature does not exceed 90°C (194°F).
Operating at higher temperatures will shorten ballast life or
may cause the thermal protection cicuit to trip.
The temperature the ballast reaches depends on the temperature of the area surrounding it — plus the heat-conducting
surface touching the ballast. Ballasts should be installed in a
manner that avoids future overheating. To maintain normal
ballast temperature, you should:
1. Mount the ballast against a flat surface of heavy gauge
metal such as the structural part of the sign.
2. K
eep the ballast as far away as possible from other
ballasts, lamps or reflective surfaces. (Lamps generate
approximately three-fourths of the heat in a plastic sign.)
The ends of the lamps are the hottest part, so you should
mount the ballast as far away from the ends as possible.
3. Paint the inside of the sign with flat white paint.
Moisture Protection
1. Vent the sign as well as possible without allowing
water to enter.
2. B
allasts should be mounted horizontally (except for weatherproof types). If the ballast must be mounted vertically,
allow room for sufficient air circulation. Wherever possible,
mount the ballast in an enclosure outside the sign by using
Universal pup tents. You can
get pup tents at no charge when you order the plastic
sign ballast. Your wholesaler will also have a supply
for your convenience.
Grounding
Plastic Sign Ballasts
The white lead of a 120-volt ballast must be connected to the
neutral or ground side of the power supply. All metal parts of
the sign, as well as the ballast case, must be grounded either
through the conduit which holds the power supply or by
direct connection with a grounding wire. An ungrounded sign
is a potential hazard—and it can give misleading symptoms
when looking for sign faults.
Proper Lamp Life and Starting
In rapid-start installations, proper filament heating is necessary for reliable starting and normal lamp life. To ensure
that proper heating is taking place, the following steps are
recommended:
1. Lamp leads should be kept as short as possible and with a
minimum of splices.
2. All connections should be soldered.
3. Maintain proper alignment and spacing of lamp holders
to ensure good contact in the sockets.
4. Mount lamps within one inch of grounded metal. This is
one lamp manufacturer’s published requirement for reliable
starting.
Light Output vs. Temperature
The light output of a fluorescent lamp varies according to the
mercury vapor pressure inside the lamp. This pressure is
controlled by the coldest spot on the bulb wall. The ballast may
start the lamp, but the light output can be very low if the bulb
wall temperature is low. Several factors influence this, including
ambient temperatures, wind, type of enclosure, etc. If maximum
light output is critical, consult a lamp manufacturer for advice.
Lamp Starting Problems
Occasionally a field problem will arise involving improper
lamp starting. The usual complaint is that the lamps start
slowly (or not at all). Here are some of the causes:
1. Low line voltage
2. Improper sign grounding
3. Insufficient or no filament voltage
4. Insufficient or no open circuit voltage
5. Dirty lamps during high-humidity operating conditions
6. Lamps improperly inserted in the sockets
If lamp starting is a problem in your installation, check the sign
grounding, filament voltage (3.4 - 3.9 volts), and open circuit
voltage. If all are normal, the probable cause is dirty lamps. The
lamps should be washed in clean water, drip-dried, and reinstalled. If this doesn’t solve the problem, contact your nearest
Universal representative for further assistance.
Short Lamp Life
If the lamp has not given proper length of service as specified
by the lamp manufacturer, the following reasons
for early failure should be considered:
1. Improper starting due to insufficient filament voltage
2. Frequent starting and short operating periods
3. Improper ballast
4. Improper voltage supply
5. Faulty wiring
6. Defective lamps
7. Lamps improperly inserted in sockets
Early lamp failure will be preceded by a dense blackening on
either or both ends of the lamps. This blackening will extend
three or four inches from the lamp base and should not be
confused with a small dense spot, which is a mercury deposit
that can occur any time during lamp life. Dense blackening
due to early lamp failure should not be confused with the gray
bands that sometimes appear toward the end of normal lamp
life (about two inches from either end of the lamp).
PAGE 6-2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Sign Ballast Footage Chart
UNIVERSAL® USB Fluorescent Sign Ballast Matrix
No. of
Lamps
Per
Ballast 2
TOTAL LAMP FOOTAGE REQUIRED
4
1-2
6
8
10
12 14 16
18
20 22 24 26 28 30 32 34 36
38 40 42 44 46 48
USB-0412-12
1-4
USB-0816-14
USB-1024-14
2-4
USB-1632-24
4-6
USB-2036-46
USB-2048-46
UNIVERSAL MAX-3 Fluorescent Sign Ballast Matrix
®
No. of
Lamps
Per
Ballast 2
TOTAL LAMP FOOTAGE REQUIRED
4
6
8
10
12 14 16
18
20 22
24
26 28 30
32
34 36
38 40 42
44 46 48
32
34 36
38 40 42
44 46 48
USB-0218-16
1-6
USB-1232-16
USB-1048-16
SIGNA® Electronic Sign Ballast Matrix
No. of
Lamps
Per
Ballast 2
1-2
TOTAL LAMP FOOTAGE REQUIRED
4
6
8
10
12 14 16
18
20 22
24
26 28 30
ESB216-12
2-4
ESB432-14
4-6
ESB848-46
1-4
ESB1040-14
Plastic Sign Ballasts LEAD LENGTHS (Inches)
Catalog
Number
White Black Blues
Reds Yellows Browns Oranges
Orange
Blacks
Blue
Whites
Red
Whites
Note: Maximum volts above ground, any lead 590 volts.
PAGE 6-3
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Plastic Sign Ballasts
PLASTIC SIGN BALLASTS - HIGH OUTPUT 800mA RS LAMPS - 120 Volts - 60 Hz
WO LAMP BALLASTS
T
USB-0412-12
24
24
38
38
48
FOUR LAMP BALLASTS
USB-0816-14
36
24
65
40
39
56
48
USB-1024-14
24
24
79
48
75
83
57
USB-1632-24
24
24
80
54
60
80
72
SIX LAMP BALLASTS
USB-2036-46
24
24
50
80
70
38
50
50
38
USB-2048-46
24
24
80
80
70
50
50
50
50
MAX-3 HIGH OUTPUT SIGN BALLASTS 800mA RS LAMPS - 120 Volts - 60 Hz
ONE TO SIX LAMP BALLASTS
USB-0218-16
24
24
60
60
60
60
60
60
60
USB-1232-16
24
24
80
60
60
80
60
60
72
USB-1048-16
24
24
80
80
70
50
60
60
50
SIGNA ELECTRONIC SIGN BALLASTS- T12 RAPID START HIGH OUTPUT LAMPS - 108 to 305 VOLTS - 50/60 Hz
ONE TO SIX LAMP BALLASTS
ESB216-12
68
68
ESB432-14
80
80
80
80
ESB848-46
80
80
80
80
80
80
HIGH
OUTPUT
BALLASTS
• Provide ultra-reliable
low-temperature starting
(as low as –20°F)
STANDARD
HIGH OUTPUT
SIGN BALLASTS
• Support 1 to 6 lamps
• Ideal for rugged outdoor
sign cabinet applications
• Class P thermally protected
Total
Lamp
Footage
Catalog
Number
Start
Temp
(°F)
Max.
Line
Cur.
Max.
Input
Watts
Open
Circuit
Wiring
Dimen.
Volt.
Diagram
Chart Ref.
PLASTIC SIGN BALLASTS - HIGH OUTPUT 800mA RS LAMPS - 120 Volts - 60 Hz
TWO LAMP BALLASTS
USB-0412-12
4´ min. - 12´ max.
FOUR LAMP BALLASTS
USB-0816-14
8´ min. - 16´ max.
USB-1024-14
10´ min. - 24´ max.
USB-1632-24
16´ min. - 32´ max.
SIX LAMP BALLASTS
USB-2036-46
USB-2048-46
LINE
20´ min. - 36´ max.
20´ min. - 48´ max.
WHITE
BLACK
BLUE
BLUE
BALLAST
Weight
(lbs.)
-20
1.35
160
500
1a, 2a
1
8
-20
-20
-20
1.90
2.70
3.50
220
325
420
590
720
950
4a, 6a, 9, 1b
4a, 6a, 9, 1b
4a, 6a, 9
2
3
4
12
14
16
-20
-20
4.00
5.00
480
600
600
720
5a, 7, 7a
5a, 7, 7a
4
4
18
18
BLACK
BLUE
BLUE
BROWN
BROWN
YELLOW
YELLOW
LINE
RED
RED
YELLOW
YELLOW
BALLAST
LINE
RED
RED
BLUE/WHITE
BLUE/WHITE
WHITE
BLACK
YELLOW
YELLOW
BALLAST
RED
RED
BLUE
BLUE
LAMP 1
LINE
LAMP 2
LAMP
LAMP
Diagram 1a
Diagram 1b
WHITE
BLACK
BROWN
BROWN
YELLOW
YELLOW
BALLAST
LINE
BLUE
BLUE
BLUE / WH
BLUE / WH
RED
RED
WHITE
BLACK
BROWN
BROWN
BLUE / WH
BLUE / WH
YELLOW
YELLOW
BALLAST
MOUNT LAMPS WITHIN 1˝ OF
GROUNDED METAL REFLECTOR
Diagram 2a
BLUE
BLUE
ORANGE / BLK
ORANGE / BLK
ORANGE
ORANGE
RED
RED
LINE
LAMP 1
LAMP 1
BLACK
WHITE
YELLOW
YELLOW
BROWN
BROWN
BALLAST
LAMP 2
LAMP 2
LAMP 1
LAMP 3
LAMP 2
LAMP 3
LAMP 4
LAMP 3
LAMP 5
LAMP 4
LAMP 6
MOUNT LAMPS WITHIN 1˝ OF
GROUNDED METAL REFLECTOR
INDIVIDUALLY CAP
THE YELLOW LEADS
MOUNT LAMPS WITHIN 1˝ OF
GROUNDED METAL REFLECTOR
Diagram 4a
Diagram 6a
Diagram 5a
LINE
BLACK
WHITE
BROWN
BROWN
BLUE / WH
BLUE / WH
YELLOW
YELLOW
BALLAST
RED
RED
BLUE / WH
BLUE / WH
BLUE
BLUE
BLUE
BLUE
ORANGE / BLK
ORANGE / BLK
ORANGE
ORANGE
RED
RED
LAMP 1
LAMP 2
LAMP 3
3
LAMP 4
4
LAMP 5
INDIVIDUALLY CAP
THE YELLOW LEADS
Plastic Sign Ballasts
Diagram 7
Diagram 9
Diagram 7a
PLASTIC SIGN FLUORESCENT BALLASTS
DIMENSION CHART - STANDARD CASE (INCHES)
Ref. #
1
2
3
4
A
B
C
D
E
10 37/64˝
1037/64˝
13 3/16˝
15 3/16˝
1145/64˝
1145/64˝
14 5/16˝
16 11/16˝
119/64˝
119/64˝
13 3/4˝
161/8˝
13/4˝
2 43/64˝
2 43/64˝
2 43/64˝
3 3/16˝
3 3/16˝
3 3/16˝
3 3/16˝
PAGE 6-4
Diagrams Notes:
Note 1: When operating a two-lamp ballast on one lamp
insulate each yellow lead.
Note 3: When operating a four-lamp ballast on three
lamps insulate each yellow blue/white, and brown
lead.
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
UNIVERSAL®
MAX-3
HIGH OUTPUT
SIGN BALLASTS
• Superior fill material coats all components and fills all
voids to dissipate heat for cooler operation, longer life.
• Supports 1 to 6 lamps, 2 to 48 feet total length
• Low watt-loss steel lamination and all-copper coils
assure cooler, more efficient operation and performance.
• Class P thermally protected
Total
Lamp
Footage
Catalog
Number
Start
Temp
(°F)
Max.
Line
Cur.
Max.
Input
Watts
Open
Circuit
Wiring
Volt.
Diagram
MAX-3 HIGH OUTPUT SIGN BALLASTS 800mA RS LAMPS - 120 Volts - 60 Hz
ONE TO SIX LAMP BALLASTS
USB-0218-16
USB-1232-16
USB-1048-16
2´ min. - 18´ max.
12´ min. - 32´ max.
10´ min. - 48´ max.
-20°
-20°
-20°
2.00
3.50
4.80
240
410
570
MAX-3
BALLASTS
625
970
800
3, 4, 5, 6, 7, 8
3, 4, 5, 6, 7, 8
1, 2, 3, 4, 7, 8
Dimen.
Chart Ref.
Weight
(lbs.)
1
1
2
15
16
18
See page 6-3 for Lead Lengths
2
3
Diagram 1
Diagram 3
Diagram 2
2
Diagram 5
3
Diagram 6
4
5
Diagram 4
3
4
Diagram 7
Diagram 8
Ref. #
1
2
A
B
C
D
E
13 3/16˝
159/16˝
145/16˝
1611/16˝
13 3/4˝
16 1/8˝
2 43/64˝
2 43/64˝
3 3/16˝
3 3/16˝
PAGE 6-5
Diagrams Notes:
Note 1: When operating a two-lamp ballast on one lamp
insulate each yellow lead.
Note 2: When operating a three-lamp ballast on two
lamps insulate each yellow and blue/white lead.
Note 3: When operating a four-lamp ballast on three
lamps insulate each yellow blue/white, and brown
lead.
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
MAX-3 Series Ballasts
MAX-3 SERIES HIGH OUTPUT SIGN BALLASTS
DIMENSION CHART
ELECTRONIC
SIGN
BALLASTS
Catalog
Number
SIGNA® ELECTRONIC
SIGN BALLASTS
• Instant start for maximum energy savings
• Simplified wiring for fewer connections
• Universal input voltage
• Parallel Lamp Operation
Total
Lamp
Footage
Start
Temp
Input
(°F)
Voltage
Max.
Input
Watts
Max.
Line
Wiring
Current (A)
Diagram
Dimen.
Chart Ref.
Weight
(lbs.)
T12HO UP TO 8’ IN LENGTH OR T8HO UP TO 6’ IN LENGTH - 120 to 277 Volts - 50/60 Hz
ONE TO TWO LAMP BALLASTS
ESB216-12
2´ min. - 16´ max.
-20
ONE, TWO, THREE OR FOUR LAMP BALLASTS
120
277
134
130
1.12
0.47
10
1
4.2
120
277
280
274
2.34
0.99
11
2
7.4
120
277
408
395
3.41
1.47
12
3
9.7
120
ESB1040-14
10´ min. - 40´ max.
-20
277
Consult www.signasign.com for complete specification information
341
331
2.85
1.25
11
3
10
ESB432-14
4´ min. - 32´ max.
-20
FOUR, FIVE OR SIX LAMP BALLASTS
ESB848-46
8´ min. - 48´ max.
-20
T12HO UP TO 8’ IN LENGTH OR T8HO UP TO 8’ IN LENGTH - 120 to 277 Volts - 50/60 Hz
ONE, TWO, THREE OR FOUR LAMP BALLASTS
Diagram 11
Electronic Sign Ballasts
Diagram 10
Diagram 12
ELECTRONIC SIGN BALLASTS
DIMENSION CHART - STANDARD CASE (INCHES)
Ref. #
1
2
3
A
B
C
D
E
10 37/64 ˝
133/16˝
15 9/16˝
1145/64˝
14 5/16˝
16 11/16˝
119/64˝
13 3/4˝
161/8˝
13/4˝
2 43/64˝
2 43/64˝
3 3/16˝
3 3/16˝
3 3/16˝
PAGE 6-6
Diagrams Notes:
When Operating less than the maximum number of
lamps, insulate unused blue leads.
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Glossary
Class P Thermal Protector–A switching device sensitive to
current and heat that automatically disconnects ballast if the
ballast temperature exceeds UL temperature limitations.
Coil–Windings of copper or aluminum wire surrounding the
steel core in ballast.
Core–Component of electromagnetic ballast that is surrounded
by the coil. Core is comprised of steel laminations or solid
ferrite material.
Core & Coil Ballast–Another term for an electromagnetic
ballast.
Crest Factor (Lamp Current Crest Factor)–Ratio of peak lamp
current to RMS or average lamp operating current.
Efficacy–Lumen output per unit of power supplied to ballast
(lumens per watt).
Electrical Testing Laboratory (ETL)–Independent testing
laboratory that performs ballast tests and certifies accuracy
of performance data.
Electrode–Metal filaments that emit electrons in a fluorescent
lamp. Negatively charged free electrons emitted by one
electrode are attracted to the positive electrode (anode),
creating an electric current and arc between electrodes.
Electromagnetic Ballast (Magnetic Ballast)–A ballast that uses
a “Core & Coil” assembly to transform electrical current to start
and operate fluorescent lamps.
EMI (Electromagnetic Interference)–Electrical interference
(noise) generated by electrical and electronic devices. Levels
generated by high frequency electronic devices are subject to
regulation by Federal Communications Commission (FCC).
Filament–Metal Tungsten wire coated with Barium Oxide that
emits electrons when voltage is applied.
Filament Voltage–Voltage applied to the lamp cathode.
Fluorescent Lamp–Gas filled lamp in which light is produced
by the interaction of electrons with phosphors lining the lamp’s
glass tube.
Foot Candles–Measure of light level on a surface being
illuminated. Defined as one lumen of light per one square
foot of surface area.
Four-Pin Compact Fluorescent Lamps–Type of lamps that do
not have any starter built into the base of the lamp. Therefore,
the ballast has the starting circuit. Traditionally 4-pin lamps are
designed to work with electronic ballasts; however, Universal
does offer magnetic ballasts to operate some 4-pin lamps.
Frequency–Rate of alteration in an AC current. Expressed in
cycles per second or Hertz (Hz).
Harmonic–An integral multiple of the fundamental frequency (60 Hz) that becomes a component of the current (see
“Harmonic Distortion”).
Harmonic Distortion–Distortion of an AC waveform caused by
multiples of the fundamental frequency (harmonics). Odd triplet
harmonics (thirds, ninths, etc.) may result in large currents on
the neutral line in a four-wire Wye three-phase system.
Hertz (Hz)–Unit used to measure frequency of alteration of current or voltage; cycles per second.
FOR MORE INFORMATION CALL
PAGE 7-1
1-800-BALLAST
(225-5278)
Glossary
AC (Alternating Current)–Current which passes from the
generator in one direction and then the other, alternately
ANSI (American National Standards Institute)–Non-profit
organization that generates voluntary product performance
standards for many U.S. industries. ANSI Standard C82.1 applies
to electromagnetic ballasts.
Arc–Intense luminous discharge formed by the passage of
electric current across a space between electrodes.
Auto Reset Shutdown Circuit–Circuit senses lamp end of life
and will automatically shut off power to the lamp(s). When a
new lamp is inserted in the socket, the ballast resets, and turns
on the lamp automatically. Some shutdown circuits require the
power to be interrupted before a new lamp
will re-light.
Ballast–Device for starting and regulating fluorescent and high
intensity discharge lamps.
Ballast Efficacy Factor (BEF) – Value used to evaluate various
lighting systems based on light output and power input. The
BEF can only be used to compare systems operating the same
type and quantity of lamps.
Ballast Factor (BF)–Measure of light output from lamp operated
by commercial ballast as compared to a laboratory standard reference ballast. Ballast factor .94 means ballast produces 94% of
light produced by ANSI C82.2 reference ballast operating same
lamps.
Ballast Hum–Sound generated by the vibration of laminations
in the electromagnetic field that transforms the current for discharge lamp use.
Ballast Losses–Power which is supplied to a ballast that is not
converted into lamp energy. Ballast loss is dissipated as heat.
Bottom Exit (BE)–A configuration with leads or a wire-trap on
the bottom or base of the ballast. This type of configuration
is usually used when the ballast is mounted onto a junction box
plate.
Bottom Exit Studs (BES)–A configuration with screw studs
mounted on the base plate or bottom of the ballast. The screws
are 3/8˝ inches long with a #8-32 thread size (#8-32 nut). They
are mounted on a two-inch center. The studs are usually used
to mount the ballast directly onto a junction
box plate.
Canadian Energy Standards – Indicates ballast complies
with Canadian Energy Standards and meets the requirements ofCAN/CSA-C654-M91.
Canadian Standards Association (CSA)–Association that
generates product performance and safety
standards for many Canadian industries.
Capacitor–Device in ballast that stores electrical energy.
Often used for power factor correction and lamp regulation(see
“Power Factor”).
Cathode–See “Electrode”.
Centigrade (C)–Celsius temperature scale where 0°C = 32°F.
Circle E–Designates a ballast meets or exceeds the
requirements of Public Law 100-357 establishing standards
of efficiency.
Glossary
Glossary
High Efficiency (Energy Saving) Electromagnetic Ballast–
Ballast with Core & Coils, designed to minimize ballast losses
compared to the “standard” ballast.
High Intensity Discharge (HID) Lamp–A lamp containing
a filled arc tube in which the active element becomes vaporized
(a gaseous state) and is discharged into the arc stream
to produce light.
High Power Factor–A ballast whose power factor is corrected to
90% or greater by use of a capacitor.
Incandescent Lamp–Lamp in which light is produced by a
filament heated by an electric current.
Input Voltage–Power supply voltage required for proper operation of an arc discharge lighting ballast.
Inputs Watts–The total power input to the ballast which
includes lamp watts and ballast losses. The total power input to
the fixture is the input watts to the ballast or ballasts and is the
value to be used when calculating cost of energy and air conditioning loads.
Instant Start Lamp–a fluorescent lamp with a single pin at each
end. The lamp is ignited by a high voltage without any
filament heating.
Instant Start–Lamp starting method in which lamps are
started by high voltage input with no preheating of lamp
filaments. Some rapid start lamps are designed so that they may
be instant started.
Laminations–Layers of steel, making up the “core” that is surrounded by the coils in a core & coil ballasts.
Lamp Current Crest Factor–See “Crest Factor”.
Lamp Filament–See “Electrode”.
Lamp Watts –Input power used to operate lamps.
Lumens/Watt–A measurement of white light produced by each output
watt.
Metal Cases–Case design used in both magnetic and
electronic ballasts. These ballasts are grounded once they
are mounted to the fixture. They meet all safety codes, some
of which do not allow plastic in open plenum areas.
National Electric Code (NEC)–A nationally accepted electrical installation code to reduce the risk of fire, developed by the
National Fire Protection Association.
National Energy Standards for Fluorescent Ballasts–A federal
law enacted in 1988 that sets energy standards for ballasts consistent throughout the United States.
NOM –Laboratory that sets safety standards for building materials, electrical appliances and other products for Mexico.
Non-PCB Capacitor–Capacitor used in ballasts to help provide
power factor correction. Contains no polychlorinated biphenyls
and meets EPA requirements.
Normal Power Factor–Ballasts with power factor less than .90
and do not incorporate any means of Power Factor Correction.
Parallel Lamp Operation–Refers to ballasts that employ multiple-output current paths from a single ballast to allow lamps to
operate independent of one another, allowing other lamps operated by the ballast to remain lit should companion lamp(s) fail.
PCB (Polychlorinated Biphenyls)–Chemical pollutant formerly
used in ballast capacitors.
Potting–Material used to completely surround and cover
components of some magnetic and electronic ballasts.
Potting compound fulfills functions of protecting components,
dampening sound, and dissipating heat.
Power Factor–Measurement of the relationship between the AC
source voltage and current. High power factor ballasts require
less AC operating current operating at the same wattage than
an equivalent low power factor ballast. Formula: Power Factor
equals Input Watts divided by the product of
Line Volts times Line Amps (Volt Amps or VA).
Power Factor Corrected–Ballasts that incorporate a means
of Power Factor Correction but whose power factor is <90% and
>50%.
Preheat Lamp–A fluorescent lamp in which the filament must
be heated by use of a starter before the arc is created. These
lamps are typically operated with electromagnetic ballasts.
Programmed Rapid Start–lamp starting method which
preheats the lamp filaments while not allowing the lamp to ignite
and then applies the open circuit voltage (OCV) to start the lamp.
The user may experience a half to one-second delay after turning
on the lamps while the pre-heating takes place. This type of starting circuit keeps lamp end blackening to a minimum and improves
lamp life performance, especially in applications where the lamps
are frequently switched on and off.
Rapid Start Lamp–A fluorescent lamp with two pins at each
end connected to the filament. The filaments are heated by the
ballast to aid in starting. Some rapid start lamps may be instant
started without filament heat, for example, the F32T8 lamp.
Rapid Start–Lamp starting method in which lamp filaments are
heated while open circuit voltage (OCV) is applied to
facilitate lamp ignition.
Series Lamp Operation–Refers to ballasts that employ a
single current path passing through all lamps operated by the
ballast. If one lamp should fail, companion lamps operated by
the same ballasts will also extinguish or dim.
Standard Alternating Current Frequency in the United States–
60 Hertz (Hz) or 60 cycles per second.
Total Harmonic Distortion (THD)–The combined effect of
Harmonic Distortion on the AC waveform produced by a ballast
or other device. Expressed as a percentage. Excessive levels of
THD can create large currents on the neutral line of a four-wire
Wye three phase system. (See “Harmonic Distortion”.)
Transients–High voltage surges through an electrical system
caused by lightning strikes to nearby transformers, overhead
lines or the ground. May also be caused by switching of motors
and compressors, as well as by short circuits or utility system
switching. Can lead to premature ballast failure.
Two-Pin Compact Fluorescent Lamps–Type of lamps that
have the glow bottle starter built into the base of the lamp.
Traditionally 2-pin lamps are designed to work with
electromagnetic ballasts.
UL (Underwriters’ Laboratories, Inc.)–Laboratory that
sets safety standards for building materials, electrical
appliances and other products.
Watts–Measurement of electrical ability to do work.
FOR MORE INFORMATION CALL
PAGE 7-2
1-800-BALLAST
(225-5278)
Index
Page #
200-C-S-P
200-H2
202-B-TC-P
202-SB-TC-P
213-TC-P
300-H2
412-L-SLH-TC-P
412-L-TC-P
413-C-TC-P
420-L-TC-P
443-L-SLH-TC-P
445-RS-WS-TC-P
446-L-SLH-TC-P
446-LR-TC-P
447-LR-TC-P
447-LR-VLH-TC-P
458-L-SLH-TC-P
480-SLH-TC-P
480-XLH-TC-P
481-LH-TC-P
487-SLH-TC-P
487-XLH-TC-P
490-XLH-TC-P
493B2
532-BR-TC-P
540-L-TC-P
546-B-TC-P
547-RS-WS-TC-P
554-L-TC-P
564-L-TC-P
567-L-TC
573-L-TC-P
595-L-TC-P
597-L-TC-P
631-LH-TC-P
698-L-SLH-TC
726-L-VLH-WS-TC-P
778-XLH-TC
806-BR-TC-P
806-SLH-TC-P
808-BR-TC-P
822-BR-TC-P
827-SLH-TC-P
828-BR-TC-P
831-TC
897-SLH-TC
930-K-TC-P
931-LH-TC-P
937-K-TC-P
1010-236RC-TC
1010-238C-TC
1010-239RC-TC
1010-245C-TC
1-24, 1-25, 1-26, 1-27
1-25, 1-26, 1-27
1-24, 1-27
1-24, 1-27
1-22
1-27
1-13, 1-14
1-30
1-13, 1-14
1-13, 1-14
1-13, 1-14
1-24
1-13, 1-14
1-30
1-26, 1-27
1-25, 1-26, 1-27
1-13, 1-14
1-17
1-17
1-16, 1-17
1-17
1-17
1-15, 1-16, 1-17
2-41
1-22
1-30
1-25, 1-26, 1-27
1-24
1-25, 1-26, 1-27
1-25, 1-26, 1-27
1-34
1-13
1-30
1-34
1-15, 1-16
1-13, 1-14
1-24
1-15, 1-16, 1-17
1-33
1-22, 1-23
1-33
1-22, 1-23
1-22, 1-23
1-22, 1-23
1-33
1-22, 1-23
1-19, 1-20
1-19, 1-20
1-19, 1-20
5-39
5-39
5-39
5-39
Catalog #
1010-246C-TC
1010-247SC-TC
1033-15S
1033-16S
1033-17S
1033-23S
1033-24S
1038-113S
1038-122S
1038-130S
1110-245SC-TC
1110-246C-TC
1110-247SC-TC
1110-564C-TC
1110-566C-TC
1110-568C-TC
1111-246C-TC
1111-247SC-TC
1120-251A-TC
11210-236C-TC
11210-239C-TC
11210-242C-TC
11210-277C-TC
11210-506C-TC
11210-539C-TC
11210-554C-TC
11210-606C-TC
1220-246C-TC
1233-10W
1233-24S
1233-35UN
1233-35W
1233-142W
1233-154W
1233-183S
1233-251UN
1233-251W
1238-133S
1238-183S
12210-236C-TC
12210-237C-TC
12210-239C-TC
12210-241C-TC
12210-261C-TC
12210-552C-TC
12210-602C-TC
12210-606C-TC
4105F2P
4105P
4112PBES
4113P
4114P
4114PBES
Page #
5-39
5-39
5-43
5-34
5-34
5-43
5-34
5-33
5-36
5-36
5-38
5-38
5-52
5-38
5-38
5-38
5-38
5-38
5-38
5-38
5-38
5-38
5-38
5-38
5-38
5-38
5-38
5-39
5-26
5-27
5-26
5-26
5-26
5-27
5-27
5-26
5-26
5-36
5-36
5-39
5-39
5-39
5-39
5-39
5-39
5-39
5-39
1-25, 4-8
1-25
4-9
4-9
4-9
4-9
Index
Index
Catalog #
FOR MORE INFORMATION CALL
PAGE 9-1
1-800-BALLAST
(225-5278)
Index
Index
Catalog #
Page #
Catalog #
Page #
4122PBES
4124PBES
4128PBES
4139F2P
4205F2P
4214PBES
4226PBES
B114PUNVDV1
B128PUNVDV1
B132I120RH-A
B132I277RH-A
B132I347HP
B132I347RH
B132IUNVEL-A
B132IUNVHE-A
B132IUNVHP-B
B132PUNVDV1
B132PUNVHP-A
B132R120S30
B132R120S50
B132R120V5
B132R277S30
B132R277S50
B132R277V5
B132R347V5
B134R120M-A
B140R120HP
B140R277HP
B154PUNVDV1
B159I120RH
B159I277RH
B214PUNVDV1
B224PUNV-C
B228PU90S50D
B228PU95S50D
B228PU115S50D
B228PUNV90-C
B228PUNV95-D
B228PUNV115-D
B228PUNVDV1
B228PUNV-C
B232I120EL
B232I120HE
B232I120L-A
B232I120RES-A
B232I120RES-G
B232I120RH-A
B232I120RHH-A
B232I277EL
B232I277HE
B232I277L-A
B232I277RH-A
4-10
4-11, 4-15
4-11, 4-15
4-19
4-8
4-9
4-11, 4-15
3-10
3-10
2-14, 2-16, 2-19, 2-30
2-14, 2-16, 2-19, 2-24, 2-26, 2-27, 2-30
2-14, 2-16, 2-19
2-14, 2-16, 2-19
2-14, 2-16, 2-19, 2-24, 2-27, 2-30
2-14, 2-16, 2-19, 2-24, 2-26, 2-27, 2-30
2-14, 2-16, 2-19, 2-24, 2-26, 2-27, 2-30
3-10
2-14, 2-16, 2-19, 2-24, 2-26, 2-29
3-13
3-13
3-12
3-13
3-13
3-12
3-12
2-38
2-37, 2-38
2-37, 2-38
3-10
2-32
2-32
3-10
2-35, 4-18, 4-19
3-15
3-15
3-15
2-34
2-34, 2-36
2-34, 2-36
3-10
2-34
2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27
2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27
2-14, 2-16, 2-19, 2-20, 2-30
2-14, 2-16, 2-19, 2-20
2-14, 2-16, 2-19, 2-20
2-14, 2-16, 2-19, 2-20, 2-24, 2-27, 2-30
2-20, 2-24
2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27
2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27
2-14, 2-16, 2-19, 2-20, 2-24, 2-27, 2-30
2-14, 2-16, 2-19, 2-20, 2-24, 2-27, 2-30
B232I277RHH-A
B232I347HP-A
B232I347HPL
B232I347L-A
B232I347RH-A
B232IUNV-C
B232IUNVEL-A
B232IUNVHE-A
B232IUNVHEH-A
B232IUNVHP-B
B232PUNVDV1
B232PUNVEL-A
B232PUNVHE-A
B232PUNVHP-A
B232SR120S30
B232SR120V5
B232SR277S30
B232SR277V5
B232SR347V5
B234SR120M-A
B234SR277M-A
B239PUNV-D
B240R120HP
B240R120RH
B240R277HP
B254P347-D
B254HRVHB-E
B254PUNVDV1
B254PUNV-D
B254PUNVHB-D
B259I120HE
B259I120HPL
B259I120RH
B259I120RHH
B259I277HE
B259I277HPL
B259I277RH
B259I277RHH
B259I347HP
B259IUNVHP-A
B260I120M-A
B260I120RH
B260IUNVHP
B286I120RH
B286I277RH
B295SR120HP
B295SRUNVHP
B332I120EL
B332I120HE
2-20, 2-24
2-14, 2-16, 2-19, 2-20, 2-24, 2-27, 2-30
2-14, 2-16, 2-19, 2-20, 2-30
2-14, 2-16, 2-19, 2-20, 2-24, 2-27, 2-30
2-14, 2-16, 2-19, 2-20, 2-24, 2-27, 2-30
2-14, 2-16, 2-19, 2-20, 2-30
2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27
2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27
2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27
2-14, 2-16, 2-19, 2-20, 2-24,
2-26, 2-27, 2-30
3-10
2-20
2-20
2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27
3-13
3-12
3-13
3-12
3-12
2-37, 2-38
2-37, 2-38
2-35, 4-19
2-37, 2-38
2-37, 2-38
2-37, 2-38
2-35, 4-20
2-35, 4-20
3-10
2-35, 4-17, 4-19, 4-20
2-35, 4-17, 4-19, 4-20
2-32
2-32
2-32
2-32
2-32
2-32
2-32
2-32
2-30, 2-32
2-32
2-39, 2-40
2-39, 2-40
2-39, 2-40
2-33
2-33
2-41, 4-32
2-41
2-15, 2-17, 2-20, 2-21, 2-24,
2-25, 2-26, 2-27, 2-28
2-15, 2-17, 2-20, 2-21, 2-24,
2-25, 2-26, 2-27, 2-28
FOR MORE INFORMATION CALL
PAGE 9-2
1-800-BALLAST
(225-5278)
Index
Page #
Catalog #
Page #
B332I120L-A
B332I120RH-A
B332I120RHH
B332I277EL
B332I277HE
B332I277L-A
B332I277RH-A
B332I277RHH
B332I347HP
B332I347HPL
B332I347RH
B332I347L
B332IHRVH-E
B332IUNVEL-A
B332IUNVHE-A
B332IUNVHEH-A
B332IUNVHP-A
B332PUNVHP-A
B332SR120S30
B332SR120V5
B332SR277S30
B332SR277V5
B340R120HP
B340R277HP
B432I120EL
B432I120HE
B432I120L-A
B432I120RES-A
B432I120RH-A
B432I277EL
B432I277HE
B432I277HEH
B432I277L-A
B432I277RH-A
B432I347HP
B432I347HPL
B432I347L
B432I347RH
B432IUNV-D
B432IUNVEL-A
B432IUNVHE-A
B432IUNVHP-A
2-15, 2-17, 2-20, 2-21, 2-30
2-15, 2-17, 2-20, 2-21, 2-24,
2-25, 2-27, 2-28, 2-30
2-21
2-15, 2-17, 2-20, 2-21, 2-24,
2-25, 2-26, 2-27, 2-28
2-15, 2-17, 2-20, 2-21, 2-24,
2-25, 2-26, 2-27, 2-28
2-15, 2-17, 2-20, 2-21, 2-30
2-15, 2-17, 2-20, 2-21, 2-24,
2-25, 2-27, 2-28, 2-30
2-21
2-15, 2-17, 2-20, 2-21
2-15, 2-17, 2-20, 2-21, 2-30
2-15, 2-17, 2-20, 2-21
2-15, 2-17, 2-20, 2-21, 2-30
2-20, 2-21, 2-24, 2-25, 2-26, 2-28
2-15, 2-17, 2-20, 2-21, 2-24, 2-25,
2-26, 2-27, 2-28, 2-30
2-15, 2-17, 2-20, 2-21, 2-24, 2-25,
2-26, 2-27, 2-28, 2-30
2-15, 2-17, 2-20, 2-21, 2-24, 2-25,
2-26, 2-27, 2-28, 2-30
2-15, 2-17, 2-20, 2-21, 2-24, 2-25,
2-26, 2-27, 2-28
2-15, 2-17, 2-20, 2-21, 2-24, 2-25,
2-26, 2-27, 2-28
3-13
3-12
3-13
3-12
2-37, 2-38
2-37, 2-38
2-15, 2-17, 2-21, 2-22, 2-25, 2-26, 2-27
2-15, 2-17, 2-21, 2-22, 2-25, 2-26, 2-27
2-15, 2-17, 2-21, 2-22, 2-25, 2-30
2-15, 2-17, 2-21, 2-22
2-15, 2-17, 2-21, 2-22, 2-25, 2-30
2-15, 2-17, 2-21, 2-22, 2-25, 2-26, 2-28
2-15, 2-17, 2-21, 2-22, 2-25, 2-26, 2-28
2-15, 2-17, 2-21, 2-22, 2-25, 2-28
2-15, 2-17, 2-21, 2-22
2-15, 2-17, 2-21, 2-22, 2-30
2-15, 2-17, 2-21, 2-22
2-15, 2-17, 2-21, 2-22, 2-30
2-15, 2-17, 2-21, 2-22, 2-30
2-15, 2-17, 2-21, 2-22
2-15, 2-17, 2-21, 2-22, 2-30
2-15, 2-17, 2-21, 2-22, 2-25, 2-28, 2-30
2-15, 2-17, 2-21, 2-22, 2-25,
2-26, 2-28, 2-30
2-15, 2-17, 2-21, 2-22, 2-25,
B432PUNVHP-A
B432P277V5-E
B432P277V5H-E
B432SR277V5
B454PUNV-E
B454PUNVHB-E
C118PUNVDV3
C126PUNVDV3
C132PUNVDV3
C140PUNVDV3
C142PUNVDV3
C213/347
C213UNV
C218/347
C218PUNVDV3
C218UNV
C226PUNVDV3
C232PUNVDV3
C240PUNVDV3
C240PUNVHP-B
C240SI120RH
C240SI277RH
C242/347
C242PUNVDV3
C242UNV
C340SI120RH
C340SI277RH
C2642/347
C2642UNV
CBT113L-120
CBT213L-120
CBT218L-120xC
CBT126L-120
CF1320H2P
CT213UNV
CT218UNVSE
ESB213-12
ESB432-14
ES1329A
ES1510A
ES1608A
ES1679A
ES1720B
ES1786X
ES4515K
ES4528X
ES4800A
ES5000GT/HT
ES5001GT/HT
ES5002GT/HT
ES5003GT/HT
2-26, 2-28, 2-30
2-15, 2-17, 2-21, 2-22, 2-25, 2-26, 2-28
3-12
3-12
3-12
2-35, 4-20
2-35, 4-20
3-10
3-10
3-10
3-10
3-10
4-9, 4-14
4-9, 4-14
4-10, 4-14
3-10
4-10, 4-14
3-10
3-10
3-10
4-19
4-19
4-19
4-11, 4-12, 4-15, 4-17, 4-18, 4-19, 4-20
3-10
4-11, 4-12, 4-15, 4-17, 4-18, 4-19, 4-20
4-19
4-19
4-11, 4-12, 4-15, 4-17, 4-18
4-11, 4-12, 4-15, 4-17, 4-20
2-34, 4-8, 4-9
2-34, 4-8, 4-9
4-10
2-34, 4-11, 4-17, 4-18
1-26, 1-27, 4-9
4-9
4-10, 4-18
7-6
7-6
2-14, 2-16, 2-20
2-14, 2-16, 2-19
2-14, 2-16, 2-19, 2-20
2-30
2-15, 2-17, 2-21, 2-22
2-42
2-35, 4-20
2-34
2-14, 2-16, 2-19, 2-20, 2-30
3-8
3-8
3-8
3-8
FOR MORE INFORMATION CALL
PAGE 9-3
1-800-BALLAST
(225-5278)
Index
Catalog #
Index
Index
Catalog #
Page #
Catalog #
Page #
ES5006BM
ES5007BMT
ES5008BM
ES5009BMT
ES5010GT/HT
ES5011GT/HT
ES5012GT/HT
ES5013GT/HT
ES5702CTL
ES5703CTL
ES5704CTL
ES5705CTL
ES5720CTL
ES5721CTL
ES5722CTL
ES5723CTL
ES5723HT
ES5733HT
ES5734HT
ES5817K
ES5818K
ES5821B
ES5822B
ES5825K
ES5826K
ES5827B
ES5828K
ES5829K
ES5830K
ES5831B
ES5832B
ES5833B
ES5834B
ES5835K
ES5836K
ES5838K
ES5839K
ES5840K
ES5842K
ES5843K
ES5844K
ES5846K
ES5847K
ES5848K
ES5849K
ES5850K
ES5851K
ES5852K
ES5853K
ES5860K
ES5861K
3-11
3-11
3-8
3-8
3-11
3-11
3-11
3-11
3-9
3-9
3-9
3-9
3-9
3-9
3-9
3-9
3-9
3-9
3-9
3-11
3-11
3-11
3-11
3-8
3-8
3-8
3-8
3-8
3-8
3-8
3-8
3-11
3-11
3-11
3-11
3-8
3-11
3-8
3-8
3-8
3-11
3-11
3-11
3-8
3-11
3-8
3-11
3-8
3-11
3-8
3-11
ES5901CTL
ES5902CTL
ES5903CTL
ES5961CTL
HPS 150-3A
HPS 150-4A
HPS 150-5B
HPS 150-45B
HPS 150-G01
HPS 400-3A
HPS 400-4A
HPS 400-45B
HPS 400-G05
HPS 450-1B
HPS 460-1B
HPS 600-1B
HPS 1000-4B
HPS 1000-55B
M35MLTLC3M
M35TRILC3M
M50MLTLC3M
M50TRILC3M
M70MLTLC3D
M70MLTLC3M
M70TRILC3M
M100MLTLC3D
M100MLTLC3M
M100TRILC3M
M150MLTLC3D
M150MLTLC3M
M150TRILC3M
M175ML5AC3M
M175MLTAC3M
M175MLTAE3M
M175TRIAC30
M232SR120C
M232SR277C
M250ML5AC3M
M250ML5AC4M
M250MLTAC3M
M250MLTAC4M
M250MLTAE3M
M250TRIAC3M
M250TRIAC4M
M260I120L
M400ML5AC4M
M400MLTAC4L
M400MLTAC4M
M400MLTAE4M
M400MLTAI4X
M400TRIAC4M
3-9
3-9
3-9
3-9
5-41
5-41
5-41
5-41
5-43
5-43
5-43
5-43
5-43
5-43
5-43
5-43
5-43
5-43
5-17
5-17
5-17
5-17
5-17
5-17
5-17
5-19
5-17
5-17
5-18
5-18
5-18
5-18
5-18
5-41
5-18
1-12
1-12
5-18
5-19
5-18
5-19
5-41
5-18
5-19
1-39, 1-40
5-19
5-19
5-19
5-41
5-42
5-19
FOR MORE INFORMATION CALL
PAGE 9-4
1-800-BALLAST
(225-5278)
Index
Page #
Catalog #
Page #
M1000ML5AC5M
M1000MLTAC5M
M1000TRIAC5M
M1500MLTAC5M
M1500TRIAC5M
M7048TLC3M
M10048TLC3M
M15048TLC3M
M17548TAC3M
M25048TAC3M
M25048TAC4M
M400120AC4M
M400208AC4M
M400277AC4M
M40027TAC4M
M40048TAC4M
M100048TAC5M
M150048TAC5M
M100120LC3N
M175120AC3M
M175277AC3M
M250120AC3M
M250208AC3M
M250230AC3M
M250240AC3M
M250277AC3M
M250347AC3M
M400230AC4M
M1000120AC5M
M1000208AC5M
M1000230AC5M
M1000240AC5M
M1000277AC5M
M1000480AC5M
M1500230AC5M
M1500480AC5M
MH 70-3B
MH 100-3A
MH 100-5A
MH 100-35B
MH 150-35B
MH 200-1B
MH 350-1A
MH150-G15
P 350-15B
P175ML5AC3M
P175MLTAC3M
P175TRIAC3M
P200ML5AC3M
P200MLTAC3M
P200TRIAC3M
P250ML5AC4M
5-20
5-20
5-20
5-20
5-20
5-17
5-17
5-18
5-18
5-18
5-19
5-19
5-19
5-19
5-19
5-19
5-20
5-20
5-17
5-18
5-18
5-18
5-18
5-36
5-18
5-18
5-18
5-36
5-20
5-20
5-36
5-20
5-20
5-20
5-20, 5-36
5-20
5-43
5-43
5-43
5-43
5-43
5-43
5-43
5-43
5-43
5-22
5-22
5-22
5-22
5-22
5-22
5-22
P250MLTAC4M
P250TRIAC4M
P320ML5AC4M
P320MLTAC4M
P320TRIAC4M
P350ML5AC4M
P350MLTAC4M
P350TRIAC4M
P400ML5AC4M
P400MLTAC4M
P400TRIAC4M
P450ML5AC4M
P450MLTAC4M
P750ML5AC5M
P750MLTAC5M
P750TRIAC5M
P1000ML5AC5M
P1000MLTAC5M
P17548TAC3M
P20048TAC3M
P25048TAC4M
P32048TAC4M
P35048TAC4M
P40048TAC4M
P45048TAC4M
P75048TAC5M
P100048TAC5M
P175277RCEM
P200277RCEM
P250277RCEM
P32027TAFXM
P320277RCEM
P350277RCEM
P350480AC4M
P400277RCEM
S35120RCEM
S70120RCEM
S50120RCEM
S50MLTLC3M
S70MLTLC3M
S70TRILC3M
S100120RCEM
S100MLTLC3M
S100TRILC3M
S150120RCEM
S150MLTLC3M
S150TRILC3M
S20048TAC4M
S200MLTAC4M
S200TRIAC4M
S250240AC4M
S250480AC4M
5-22
5-22
5-23
5-23
5-23
5-23
5-23
5-23
5-24
5-24
5-24
5-24
5-24
5-24
5-24
5-24
5-24
5-24
5-22
5-22
5-22
5-23
5-23
5-24
5-24
5-24
5-24
5-22
5-22
5-22
5-38
5-23
5-23
5-23
5-24
5-26
5-26
5-26
5-26
5-26
5-26
5-26
5-26
5-26
5-27
5-27
5-27
5-27
5-27
5-27
5-27
5-27
Index
Catalog #
FOR MORE INFORMATION CALL
PAGE 9-5
1-800-BALLAST
(225-5278)
Index
Index
Catalog #
Page #
S250ML5AC4M
S250MLTAC4M
S250TRIAC4M
S40048TAC4M
S400ML5AC4M
S400ML5AC5M
S400MLTAC4M
S400MLTAC5M
S400TRIAC4M
S400TRIAC5M
S430MLTAC4M
S600MLTAC5M
S100024TAC5M
S1000480AC5M
S1000ML5AC5M
S1000MLTAC5M
S1000TRIAC5M
S7027TLC3M
S7048TLC3M
S10027TLC3M
S10048TLC3M
S15027TLC3M
S15048TLC3M
S25048TAC4M
S40048TAC5M
S400230AC4M
S400277AC4M
S400480AC4M
S100048TAC5M
S150208LC3M
S250230AC4M
S400230AC4M
S1000230AC5M
SA-55
SA-100
USB-0218-16
USB-0412-12
USB-0816-14
USB-1024-14
USB-1048-16
USB-1232-16
USB-1632-24
USB-2036-46
USB-2048-46
W-589-D-TC-P
5-27
5-27
5-27
5-28
5-28
5-28
5-28
5-28
5-28
5-28
5-28
5-29
5-29
5-29
5-29
5-29
5-29
5-26
5-26
5-26
5-26
5-27
5-27
5-27
5-28
5-28
5-28
5-28
5-29
5-27
5-27, 5-36
5-36
5-36
5-43
5-43
7-3, 7-5
7-3, 7-4
7-3, 7-4
7-3, 7-4
7-3, 7-5
7-3, 7-5
7-3, 7-4
7-3, 7-4
7-3, 7-4
1-13, 1-14, 1-24
Catalog #
Page #
FOR MORE INFORMATION CALL
PAGE 9-6
1-800-BALLAST
(225-5278)
Limited Warranty
Universal Lighting Technologies, 26 Century Blvd., Suite 500, Nashville, TN 37214-3683, 1-800-BALLAST, (hereinafter called “Universal”)
warrants to the purchaser that its lamp ballasts (hereinafter called “Lighting Products”) will be free from defects in material and workmanship for the specified warranty periods beginning from the date of manufacture.
TRIAD Electronic Fluorescent Ballasts
Universal, Energy Saving Electromagnetic Fluorescent Ballasts
AddressPro, SuperDim, and DaliPro Ballasts
Standard Universal Electromagnetic, Fluorescent & HID Ballasts
Universal Sign Ballasts
MAX-3 Series Sign Ballasts
Basic-12 and Homestar Electronic Ballasts
VS Lampholders
VS Brand Magnetic IEC, Electronic IEC, Ignitors, Switches and Capacitors
Electronic HID
up to 60 Months*
36 Months
36 Months
24 Months
24 Months
36 Months
36 Months
36 Months
36 Months
up to 60 Months*
*Consult individual product information sheets at www.unvlt.com for specific warranty information.
If it appears within the specified warranty period that any Universal Lighting Product does not meet the warranty specified above, Universal
will provide a replacement lighting product. Universal extends this limited warranty to the first end-user purchaser only. This warranty is
conditional based upon proper storage, installation, use and maintenance.
This warranty is not applicable to, and Universal makes no warranty whatsoever with respect to, any Lighting Product not installed and
operated in accordance with the National Electric Code (NEC), the Standards for Safety of Underwriters Laboratories, Inc. (UL), Standards for
the American National Standards Institute (ANSI), in Canada, the Canadian Standards Association (CSA), or the International Electrotechnical
Commission (IEC). Nor is this warranty applicable to any Lighting Product which has not been installed and operated in accordance with
Universal’s specifications and connection diagrams or Lighting Products which have been submitted to abnormal operating conditions. This
includes, but is not limited to, excessive temperatures as specified in Universal’s published literature. The conditions for any tests (to be)
performed on Lighting Products which are claimed to have not performed in accordance with the terms of the warranty shall be mutually
agreed upon in writing and Universal may be represented at any such tests.
NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY BEYOND THE AFOREMENTIONED
WARRANTY PERIOD. The foregoing warranty is exclusive of all other statutory, written or oral warranties and no other warranties of any kind,
statutory or otherwise, are given or herein expressed. Warranty claims are to be made in accordance with Universal’s published Warranty
Service Program, which is available upon request. This warranty sets forth Universal’s obligations and responsibilities regarding its Lighting
Products and is the exclusive remedy available to the claimant.
LIMITATIONS OF LIABILITY. Under no circumstances, whether as a result of breach of contract, breach of warranty, tort, strict liability or
otherwise, will Universal be liable for consequential, incidental, special or exemplary damages, including, but not limited to, loss of profits,
loss of use or damage to any property or equipment, cost of capital, cost of substitute product, facilities or services, down time costs or
claims of claimant’s customers. Universal’s liability for all claims of any kind or for any loss or damages arising out of, resulting from or
concerning any aspect of this warranty or from the Lighting Products or services furnished hereunder, shall not exceed the price of the
specific Lighting Product which gives right to the claim, except in accordance with Universal’s Technical Engineering Service Program.
STATE LAW RIGHT. Some states do not allow the exclusion or limitation of consequential or incidental damages or the duration of time for
an implied warranty. Therefore, the limitations or exclusions of consequential or incidental damage and implied warranties may not apply to
certain claimants. This warranty provides the claimant with specific legal rights and claimants may have other rights that vary from state to
state.
Universal Lighting Technologies, Inc. • 26 Century Blvd., Suite 500 • Nashville, Tennessee 37214-3683 • 1-800-BALLAST
Form No. LPGWTY0410
IT’S EASY TO REACH US...
Universal Lighting Technologies, Inc.
26 Century Blvd., Suite 500
Nashville, TN 37214-3683
General Info: (615) 316-5100
For Technical Engineering Services (TES), application
support and warranty information, call 1-800-BALLAST
Website:
Email: webmaster@unvlt.com
Universal Lighting Technologies is a subsidiary of
Panasonic Electric Works Co., Ltd., a member of the Panasonic Group
All specification information is subject to change without
notification. ULTNAV0710
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23 Modify Date : 2010:07:22 09:07:31-05:00 Create Date : 2010:07:22 09:07:31-05:00 Metadata Date : 2010:07:22 09:07:31-05:00 Creator Tool : Adobe InDesign CS3 (5.0.4) Format : application/pdf Document ID : uuid:e740228c-2912-c340-bb68-d14ef7defdb8 Instance ID : uuid:add1a082-a1a3-2845-a7e6-44cc7be7ee0f Producer : Adobe PDF Library 8.0 Page Count : 195 Creator : Adobe InDesign CS3 (5.0.4) Trapped : FalseEXIF Metadata provided by EXIF.tools