661870 Catalog
185820-Brochure 185820-Brochure 185820-Brochure 768386 Batch5 unilog cesco-content
2014-07-05
: Pdf 661870-Catalog 661870-Catalog 768386 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 195
Download | |
Open PDF In Browser | View PDF |
Table of Contents Fluorescent Electromagnetic Ballasts Section 1- Page Product Overview............................................................................................................................................1-2 Application Operation Information.................................................................................................................1-4 Typical Specifications......................................................................................................................................1-8 Lead Lengths....................................................................................................................................................1-9 T8 (265 mA)..................................................................................................................................................1-10 T12..................................................................................................................................................................1-11 T12 High Output............................................................................................................................................1-13 T12 Very High Output...................................................................................................................................1-17 Circline...........................................................................................................................................................1-18 T12 Slimline..................................................................................................................................................1-19 Preheat and Trigger Start . ............................................................................................................................1-21 Export ............................................................................................................................................................1-25 Dimming .......................................................................................................................................................1-29 Export ............................................................................................................................................................1-30 Fluorescent Electronic Ballasts Section 2- Page Product Overview............................................................................................................................................2-2 Application Operation Information.................................................................................................................2-4 Typical Specifications......................................................................................................................................2-7 F17T8.............................................................................................................................................................2-14 F25T8.............................................................................................................................................................2-16 F32T8 (32, 30, 25 & 28 Watt Four Foot Lamps)........................................................................................2-19 F40T8.............................................................................................................................................................2-31 F96T8 Slimline..............................................................................................................................................2-33 F96T8HO High Output.................................................................................................................................2-34 T5....................................................................................................................................................................2-35 T5HO..............................................................................................................................................................2-37 T12 ................................................................................................................................................................2-39 T12 Slimline...................................................................................................................................................2-41 T12HO High Output......................................................................................................................................2-43 T2....................................................................................................................................................................2-44 Energy Management Systems Section 3- Page --DCL With DEMANDflex Product Overview............................................................................................................................................3-2 DemandFlex T8...............................................................................................................................................3-3 DemandFlex T5, T5HO & TT5......................................................................................................................3-6 DemandFlex T8 Wiring Diagram...................................................................................................................3-7 FOR MORE INFORMATION CALL i 1-800-BALLAST (225-5278) Table of Contents Controllable Lighting Section 3- Page --Fluorescent Energy Management/Dimming Ballasts and Controls Product Overview..........................................................................................................................................3-10 Ballastar® Light Level Switching................................................................................................................3-10 SuperDim® Analog Dimming......................................................................................................................3-11 DaliPro™ Digital Dimming..........................................................................................................................3-13 Application Operation Information...............................................................................................................3-14 Controls for Analog Dimming Ballasts........................................................................................................3-15 DaliPro®........................................................................................................................................................3-16 SuperDim®....................................................................................................................................................3-17 Ballastar® 0-10 Volt......................................................................................................................................3-18 Ballastar® Light Level Switching................................................................................................................3-19 Table of Contents Compact Fluorescent Ballasts Section 4- Page Product Overview............................................................................................................................................4-2 Understanding Compact Fluorescent Technology.........................................................................................4-3 Configurations..................................................................................................................................................4-4 Lamp Matrix....................................................................................................................................................4-5 Typical Specifications......................................................................................................................................4-6 Nomenclature...................................................................................................................................................4-7 5-13 Watt Twin, Quad and Triple...................................................................................................................4-8 18 Watt Twin, Quad and Multiple................................................................................................................4-10 26-28 Watt Quad and Triple........................................................................................................................4-11 32 to 70 Watt Triple and Multiple................................................................................................................4-12 2D and T5 Circular........................................................................................................................................4-14 Long Twin T5................................................................................................................................................4-18 High Intensity Discharge (HID) Ballasts Section 5- Page Product Overview............................................................................................................................................5-3 Oil Filled Capacitors........................................................................................................................................5-5 Dry Capacitors.................................................................................................................................................5-7 Bracket Reference Chart..................................................................................................................................5-9 Application and Operation Information........................................................................................................5-10 Nomenclature.................................................................................................................................................5-13 Typical Specifications....................................................................................................................................5-14 Distributor Replacement Kits........................................................................................................................5-15 Core and Coil Metal Halide ........................................................................................................................................5-19 Pulse Start Metal Halide......................................................................................................................5-23 High Pressure Sodium..........................................................................................................................5-30 50 Hz Core and Coil Ballasts........................................................................................................................5-34 F-Can Ballast..................................................................................................................................................5-36 Potted Core and Coil......................................................................................................................................5-39 Indoor Encased...............................................................................................................................................5-40 Ignitors............................................................................................................................................................5-41 Reference Drawings.............................................................................................................................5-43 Table of Contents Electronic High Intensity Discharge (eHID) Ballasts Section 6- Page Product Overview............................................................................................................................................6-2 Product Family Chart.......................................................................................................................................6-3 Wiring Diagrams..............................................................................................................................................6-4 Dimensions.......................................................................................................................................................6-5 Application and Operation Information..........................................................................................................6-7 Sign Ballasts Section 7- Page Application and Operation Information..........................................................................................................7-2 Sign Ballast Footage Chart & Lead Lengths..................................................................................................7-3 Standard............................................................................................................................................................7-4 Max-3 Series....................................................................................................................................................7-5 SIGNA Electronic Sign Ballasts.....................................................................................................................7-6 FOR MORE INFORMATION CALL ii 1-800-BALLAST (225-5278) Table of Contents Glossary Section 8- Page ..........................................................................................................................................................................7-1 Obsolete Cross Reference Section 9- Page ..........................................................................................................................................................................8-1 Index Section 10- Page ..........................................................................................................................................................................9-1 Warranty Section 11- Page ........................................................................................................................................................................10-1 Table of Contents FOR MORE INFORMATION CALL iii 1-800-BALLAST (225-5278) Electromagnetic Fluorescent Ballasts A Wide Product Line To Meet All Your Needs Our comprehensive line of magnetic ballasts offer outstanding performance and value. These energy-efficient ballasts carry the trusted UNIVERSAL® brand and are available for a wide variety of applications. Universal Lighting Technologies’ (“Universal”) full spectrum of solutions includes ballasts for T12/T10/T8 applications, plus Slimline, Circline, trigger-start and preheat ballasts. We also make rugged weatherproof ballasts ... and models specifically engineered for the fast growing export market. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group Fluorescent-Electromagnetic Our comprehensive line of energy-efficient magnetic ballasts carry the trusted UNIVERSAL® brand name. Product Overview Rapid Start Ballasts These ballasts provide smooth starting to Rapid Start lamps — reaching full brightness in about two seconds without the use of starters. They have built-in filament windings that energize the lowvoltage cathodes in Rapid Start lamps. Because electrodes are continuously heated, less voltage is required to strike an arc through a Rapid Start lamp than a Slimline one. Ballasts for T12/T10 Applications Universal offers a wide variety of T12 and T10 ballasts to operate 1 - 3 Rapid Start lamps. This lamp/ballast system provides smooth, virtually instant starting without the use of starters (30- and 40-watt T12 models and 40-watt T10 models are available). Models for U-lamp applications are also available. UNIVERSAL® PLUS models are available for use where maximum efficiency is required. These “hybrid” type ballasts in corporate an electronic switch which disconnects power to the lamp cathodes after start-up, saving additional energy. Ballasts for T8 Applications Universal’s T8 product offering includes models for F17, F25, F32 and F40 type T8 lamps. This product line features our OcTek™ electromagnetic ballast models. These models are low initial cost energy efficient options for use with F32T8, 4 foot Rapid Start lamps. These models are available in several variations, including full, medium, low light output and hybrid versions (OcTek™ Plus). These models maximize energy savings and provide effective choices when retrofitting 4-foot T12 fixtures. T12/T10 Applications T8 Applications Slimline Ballasts Fluorescent-Electromagnetic Slimline Ballasts Our Slimline models are designed for use with single-pin Slimline lamps. They do not require the use of starters. These ballasts deliver a high starting voltage to the lamps, enabling an arc to strike through the tube without preheating the lamp cathodes (which are specially constructed to withstand the shock). Rapid Start Ballasts PAGE 1-2 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Product Overview Circline Ballasts These products are available in 430 mA Rapid Start and preheat types, designed for use with Circline lamps. The operating characteristics are the same for both Circline and conventional lamps. All Circline socket wires are fully sleeved. Trigger-Start Ballasts These ballasts are designed for use with general fluorescent lamps and do not require the use of starters. They contain preheat windings which allow regular lamp filaments to be heated in one second. However, they require a higher open-circuit voltage than Rapid Start ballasts. Preheat Ballasts These units are designed for use with general fluorescent lamps and require the use of starters. These ballasts deliver an opencircuit voltage high enough to activate the starter to preheat lamp filaments to a temperature approximately 1750° F. After a few seconds, the starter opens the filament circuit. This provides an additional power surge to enable an electric arc to strike through the lamp and ignite it. Lamp current is then limited by the ballast to an operating level proper for the lamp. Preheat Ballast Export (50/60 Hz) Ballasts Our export product offering consists of a variety of one- and twolamp models for Rapid Start, Preheat, High Output, Slimline, and 1500 mA lamps. Included in this product line are ballasts for 50 and 60 Hz applications, including 120, 127 and 220 volts. Many of these models are available with resetting thermal protection. Export (50/60 HZ) Ballast Fluorescent-Electromagnetic PAGE 1-3 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Application And Operating Information SAFETY Subjecting a ballast to excessive voltage for an extended period of time results in the deterioration of the insulation. This insulation breakdown will cause early ballast failure. Low voltage has no damaging effect on the ballast. However, lamps may not start reliably, and early lamp failure could result. NEC & UL Requirements Ballast installation presents the possibility of exposure to potentially hazardous voltages and should be performed only by qualified personnel. All installation, inspection and maintenance should be performed only with power to the fixture turned off. Additionally, all fixtures and ballasts must be installed and operated in compliance with the National Electrical Code, Underwriters Laboratories Inc. (UL) requirements and all applicable codes and regulations. Internal Ballast Protection Class P Classification - Since January 1, 1984, the National Electrical Code requires that “where Fluorescent fixtures are installed indoors, the ballast shall have thermal protection integral within the ballast except for simple reactance ballasts.” This ruling applies to replacement ballasts as well as to those contained within new light fixtures. In compliance with the National Electrical Code, UL has established a Class P ballast classification for fluorescent light fixtures indoors. A Class P ballast must employ internal thermal protection limiting its operating temperature. Universal UL-approved Class P ballasts comply with the National Electrical Code requirement and are equipped with an automatic resetting thermal protector, built-in and adjacent to the transformer coils. The resetting thermal protector functions as a thermostat which will open and temporarily deactivate the ballast when it exceeds the permissible temperature. It will reset when the ballast cools to a safe operating temperature. The ballast will continue to cycle until the cause of overheating is eliminated. If the ballast is defective, it must be replaced. If the cause is external, a Class P ballast will resume normal operation after abnormal conditions are eliminated. Polarity Polarity refers to the proper connection of ballast lead wires to line wires. To aid you in making a correct installation, Universal ballast leads are color-coded for easy identification. The WHITE ballast lead is to be connected to the neutral (grounded) and the BLACK (or black with white tracer) lead always to the phase (“hot”) line wire. Systems where neither of the line wires are at ground potential require specially designed ballasts. A change in polarity may result in the voltage from the lead to the ground exceeding UL-specified limits. In some types of ballasts, a change in polarity may decrease voltage from the lead to the ground, thereby impeding the starting dependability of the ballast. Fluorescent-Electromagnetic Grounding Ballast cases and fixtures must always be grounded. The ballast case may be grounded to the fixture or otherwise grounded. It could be hazardous to make contact with an ungrounded fixture or ballast when in operation. Neglecting to properly ground the ballast and fixture combination may also result in failure of certain lamps to start or for unacceptable levels of electromagnetic noise to be conducted onto the power lines. Fusing Class P ballasts do not require fusing. Fusing can be used when a single circuit has a large number of fixtures/ballasts. For a comprehensive list of appropriate fuses, contact our Technical Engineering Services (TES) Department at 1-800-BALLAST or check out our TES home page at www. unvlt.com Operating Line Voltage Limits To receive the full benefits of rated lamp output and to prolong ballast life, it is essential that voltage supplied to an installation be maintained within limits prescribed for each circuit. These limits are listed below: Nominal Voltage 120 220 240 277 347 480 600 VOLTAGE RANGE Minimum Maximum 110 205 220 255 315 450 570 PAGE 1-4 125 232 250 290 364 505 630 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Application And Operating Information PERFORMANCE Lamp Connections Electromagnetic fluorescent ballasts are designed to generate voltages in excess of 300 volts. It is imperative that proper connection to good quality sockets be assured in accordance with wiring diagrams on each page of the catalog and on product labels. Some applications may not require the use of all of the ballasts output leads. If any leads are not to be connected, each should be individually capped and insulated to at least 600 volts. Application Versatility Many models are designed to allow for applications with different types or quantities of lamps. Use of products other than noted is not covered by UL Listing and/or CSA certification and cannot be warranted. Audible Noise (Sound) Electrical equipment, including most fluorescent lamp ballasts, produces some noise. Care must be taken to select a ballast with the proper sound rating for a particular lighting installation. Ballast sound will be noticeable only when it exceeds the ambient sound level. Although no industry standards currently exist, the generally accepted criteria for sound rating specifications are as follows: Average Ambient Noise Ballast Recommendation < 30 decibels A Noisy Office or Retail 31-36 decibels B Factory, Outdoor C Location Typical Office > 36 decibels Remote Mounting Excessive hot or cold temperatures, audible noise requirements or a desire to operate lamps in more than one fixture with the same ballast (master/slave), may make it desirable to mount the ballast remotely. Care must be taken to allow for ballast heat dissipation and proper grounding. In any application, the wire used to extend leads must be at least as large as the wire supplied on the ballast (18 AWG) with an insulation rating of 1000 VAC at 90°C. Lead lengths in excess of those noted cause loading effects that can dramatically impact ballast performance and void the warranty. Electromagnetic and hybrid ballasts may be remote mounted according to the table below: Wire Size 800 mA - HO 1500 mA - VHO Instant Start (Slimline) Red/Blue Leads Yellow Leads Red/Blue Leads Yellow Leads All Leads 544’ 340’ 214’ 134’ 84’ 52’ 30’ 384’ 240’ 150’ 94’ 60’ 36’ 20’ 272’ 170’ 107’ 67’ 42’ 26’ 21’ 192’ 120’ 75’ 47’ 30’ 18’ 15’ 544’ 340’ 214’ 134’ 84’ 52’ 30’ PAGE 1-5 Fluorescent-Electromagnetic #6 #8 #10 #12 #14 #16 #18 30-40 Watt Rapid Start FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Application And Operating Information PERFORMANCE Fluorescent-Electromagnetic Operating Temperature Most fluorescent ballasts and lamps are designed to provide optimum performance at ambient temperature of 77˚F. Three key performance attributes can be impacted by the ambient (room) temperature of the installation: • Lamp Starting Dependability Fluorescent lamps are inherently more difficult to start at low temperatures. All ballasts have limitations as to their ability to start lamps at low ambient temperatures. In this catalog, the low starting point for each lamp/ballast combination appears in the column marked “Minimum Starting Temperature.” • Light Output Optimum light output from fluorescent lamps is achieved when the lamp wall is at 100-110°F. Any substantial excursion (either colder or warmer) will result in a reduction in light output. RECOMMENDATIONS... • Selection of a proper ballast to match the requirements of the lamp, fixture, voltage and installation. • Mounting of ballast within the fixture with as much surface contact as possible between the ballast and metal portions of the fixture. • The use of heat-conducting dissipators (radiators), if necessary, which increase surface contact between the ballast and fixture. • If necessary, locate the ballast in a remote, cooler area outside the fixture. • Planned lamp maintenance – the organized replacement of failed and failing lamps, particularly with Preheat or Slimline Systems. • Use of special LOW HEAT (-LH) rise, VERY LOW HEAT (-VLH) rise and SUPER LOW HEAT (-SLH) rise ballasts where available and necessary. • Ballast Life A fluorescent lamp ballast, like any other electrical device, generates heat during its normal operation. Ballast temperatures should be kept as low as possible. Maximum dissipation of heat through fixture design and proper ballast installation will help. Although excessive temperature may not cause the ballast to fail immediately, it can dramatically shorten ballast life. To assure maximum life, the ballast case temperature should not exceed 90˚C. CAUSES OF BALLAST OVERHEATING: • Incorrect primary voltage or frequency • Incorrect size, type or number of lamps • Failed lamp starter • Incorrect wiring • Poor heat dissipation due to surrounding insulation • Sealed (Vapor Tight) Fixtures - Unusual heat build-up due to lack of ventilation in fixtures may cause thermal (on/off) cycling of certain ballasts. Consult Universal for specific recommendations. PAGE 1-6 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Application And Operating Information LOW-LEAKAGE CURRENT TO GROUND BALLASTS Many one- and two-lamp, 30- and 40-watt high power Rapid Start ballasts – and two- and three-lamp 20-watt Trigger Start ballasts – meet requirements for “low-leakage-current-to-ground.” Those most frequently used in low-leakage applications are listed below. Line Voltage Lamps @ 60Hz (1)F40T12/RS 120 (2)F40T12/RS 120 (1)F40T12/RS 277 (2)F40T12/RS 277 (2)F20T12 120 Maximum Leakage To Ground 30uA 30uA 50uA 50uA 15uA Catalog Number 412-L-SLH-TC-P 446-L-SLH-TC-P 458-L-SLH-TC-P 443-L-SLH-TC-P 447-LR-VLH-TC-P Other ballasts can also be manufactured to meet low-leakage requirements. Consult Universal’s Technical Engineering Services Department at 1-800-BALLAST for complete information regarding low-leakage ballasts. TYPE 1 BALLASTS All Universal outdoor non-weatherproof magnetic ballasts (except those for sign applications) are designed to meet UL requirements for Type 1 use (metal enclosure required for wet or damp locations). BALLASTS FOR GERMICIDAL LAMPS Universal manufactures ballasts to operate germicidal lamps. When ordering, make sure the ANSI designation of the germicidal lamp matches exactly with the ballast’s recommended application. Several typically encountered germicidal lamps are listed below along with the proper Universal ballast for their operation. Contact Universal’s Technical Engineering Services at 1-800-BALLAST for additional information or applications not listed Germicidal Lamp Universal Ballast See Page Number (1)G15T8 200-H2 1-46 – 1-48 Fluorescent-Electromagnetic All high power factor ballasts are equipped with capacitors. Oil-filled capacitors contain non-resetting internal protection and are manufactured without PCBs. PAGE 1-7 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Specifications TYPICAL SPECIFICATIONS FOR ELECTROMAGNETIC BALLASTS 1. Ballasts shall be certified energy saving magnetic type and operate lamps at a frequency of 60 Hz. 2. Ballasts shall be specifically designed to operate (Quantity & Type) lamps. 3. Ballasts shall operate from 60 Hz input source of _____ volts, and tolerate sustained variations of +5%-10% with no damage to the ballasts. 4. Ballasts shall provide transient immunity as specified by ANSI C62.41-1991, Location Category A1. 5. Ballasts shall provide starting sequence consistent with ANSI standard C82.1. 6. Ballasts shall tolerate sustained open circuit and short circuit output conditions with no damage to the ballasts. 7. Ballasts shall be: – UL LISTED as Class P, and for use in indoor or Type 1 outdoor applications. – CSA CERTIFIED where applicable (120 and 347 volt models). 8. Ballasts shall tolerate operation, in most fixtures, at ambient temperatures up to 105°F (40°C). Ballast enclosure is limited to 90˚C maximum temperature. 9. Ballasts shall have Power Factor greater than .90. 10. Lamp Current Crest Factor (ratio of peak to RMS lamp current) shall be 1.7 or less in accordance with lamp manufacturers recommendation and ANSI C82.1. – 1.85 or less for instant start slimline (also per ANSI C82.1). 11. Ballasts shall have a Ballast Factor greater than .925 per ANSI C82.1. Fluorescent-Electromagnetic – .95 or greater for HO and VHO applications. 12. Input current Total Harmonic Distortion shall not exceed .32 per ANSI C82.1. 13. Ballasts shall be fully encapsulated (potted) to ensure maximum thermal and structural integrity. 14. Manufacturer shall provide written warranty against defects in material or workmanship. 15. Manufacturer shall have been manufacturing electromagnetic ballasts for at least twenty years. 16. Ballasts shall be manufactured in North America. 17. Universal model ___________ (or approved equal). PAGE 1-8 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Lead Lengths Lead Quantities (per color), Exits (L=Left, R=Right, B=Bottom) and Lengths (in inches, +/- 1”) Black/White Black/White White Red Blue Yellow Blue/White Brown Red/White R R 12 27 2 R 12 1 L 12 1 2 R L 12 12 2 L 12 2 L 12 Length Quanti ty Exit Length Quanti ty Exit Length 2 2 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electromagnetic 200-C-S-P 1 R 12 2 R 12 1 R 12 1 R 12 1 R 12 200-H2 2 8-15 202-B-TC-P 1 L 12 1 L 12 1 R 12 202-SB-TC-P 1 12 2 12 1 26 1 12 1 12 213-TC-P 1 L 12 1 L 12 1 R 12 1 R 12 412-L-SLH-TC-P 1 L 12 1 L 12 2 L 12 412-L-TC-P 1 L 12 1 L 25 2 L 37 413-C-TC-P 1 L 9 1 L 29 2 R 30 1 L 29 420-L-TC-P 1 L 20 1 L 20 2 R 24 2 R 24 2 L 36 443-L-SLH-TC-P 1 L 12 1 L 12 2 R 12 2 R 12 2 L 12 445-RS-WS-TC-P 1 L 12 2 12 2 R 12 1 R 12 446-L-SLH-TC-P 1 L 12 1 L 12 2 R 12 2 R 12 2 L 12 446-LR-TC-P 1 L 22 1 L 22 2 R 26 2 R 26 2 L 36 447-LR-TC-P 1 L 10 1 L/R 10 2 R 13 2 R 13 2 L 18 447-LR-VLH-TC-P 1 L 10 1 L 10 2 R 13 2 R 13 2 L 18 458-L-SLH-TC-P 1 L 12 1 L 12 2 L 12 2 R 12 480-SLH-TC-P 1 L 18 1 L 18 2 R 46 2 R 46 2 L 65 480-XLH-TC-P 1 L 12 1 L 12 2 R 12 2 R 12 2 L 12 481-LH-TC-P 1 L 10 1 L 10 2 R 44 2 L 60 487-SLH-TC-P 1 L 18 1 L 18 2 R 46 2 R 46 2 L 65 487-XLH-TC-P 1 L 12 1 L 12 2 R 12 2 R 12 2 L 12 490-XLH-TC-P 1 L 18 1 L 18 2 R 33 2 R 33 2 L 51 502-A-TC-P 1 L 12 1 L 12 2 R 12 1 L 12 2 R 12 532-BR-TC-P 1 L 12 1 L 12 1 R 12 1 R 12 540-L-TC-P 1 L 20 1 L 20 2 R 25 2 R 25 2 L 37 546-B-TC-P 1 L 12 1 L 12 2 R 12 1 L 12 547-RS-WS-TC-P 1 L 12 2 L/R 12 2 R 12 1 R 12 554-L-TC-P 1 L 12 1 L 12 2 R 12 2 R 12 2 L 12 564-L-TC-P 1 L 10 1 L 10 2 R 13 2 R 13 2 L 16 567-L-TC 1 L 10 1 L 10 2 R 13 2 R 13 2 L 16 573-L-TC-P 1 L 12 1 L 12 2 R 12 2 R 12 2 L 12 595-L-TC-P 1 L 20 1 L 20 2 R 24 2 R 24 2 L 36 597-L-TC-P 1 L 10 1 L 10 2 R 13 2 R 13 2 L 16 631-LH-TC-P 1 L 18 1 L 18 2 R 20 2 R 20 2 L 32 698-L-SLH-TC 1 L 22 1 L 22 2 R 26 2 R 26 2 L 36 726-L-VLH-WS-TC-P 1 L 12 1 L 12 2 L 12 2 R 12 4 L/R 12 757-XLH-TC 1 L 18 1 L 18 2 R 46 2 R 46 2 L 65 778-XLH-TC 1 L 18 1 L 18 2 R 33 2 R 33 2 L 51 789-SLH-TC-P 1 L 10 1 L 10 2 R 10 2 R 10 2 L 10 806-BR-TC-P 1 L 68 1 L 68 1 R 44 1 R 44 806-SLH-TC-P 1 L 12 1 L 12 1 R 12 1 R 12 808-BR-TC-P 1 L 68 1 L 68 1 R 44 1 R 44 822-BR-TC-P 1 L 8 1 L 68 1 R 44 827-SLH-TC-P 1 L 12 1 L 12 1 R 12 1 R 12 828-BR-TC-P 1 12 1 L 12 1 R 12 831-TC 1 L 73 1 L 73 1 R 49 1 R 49 881-BR-TC-P 1 L 12 1 L 12 1 R 12 1 R 12 897-SLH-TC 1 L 12 1 L 12 1 R 12 1 R 12 930-K-TC-P 1 L 12 1 L 12 2 R 12 2 R 12 2 L 12 931-LH-TC-P 1 L 12 1 L 12 2 R 12 2 R 12 2 L 12 937-K-TC-P 1 L 12 1 L 12 2 R 12 2 R 12 2 L 12 CF1320H2P 1,1 L,R 9,18 M232SR120C 1 L 20 1 L 20 2 R 24 2 R 24 2 L 36 M232SR277C 1 L 20 1 L 20 2 R 24 2 R 24 2 L 36 W-589-D-TC-P 1 L 12 1 L 12 2 R 12 2 R 12 2 L 12 4105F2P 2 L 10 4105P 2 L 12 PAGE 1-9 Quanti ty Exit Length Quanti ty Exit Length Quanti ty Exit Length Quanti ty Exit Length Quanti ty Exit Length Quanti ty Exit Length Quanti ty Exit Catalog # Black T8 UNIVERSAL® ELECTROMAGNETIC BALLASTS • 265 mA High Output Lamps • 4´ Lamp Applications • OcTek™ Series Featured Fluorescent-Electromagnetic FOR F32T8 and F32T8/U LAMPS T8 U-Shaped Lamps Input Power Ballast (Watts) Factor Lamp Certification Line Catalog Qty. Descr. Volts Number NOM F32T8 - High Power Factor OcTek® 2 Rapid 120 M232SR120C • • • • 2 Rapid 277 M232SR277C • • • F32T8/U - High Power Factor OcTek™ 2 Rapid 120 M232SR120C • • • • 2 Rapid 277 M232SR277C • • • Line Current (Amps) Overall Dimensions Draw # L W D2 9 1/2 2 3/8 WIRING DIAGRAMS Mounting Dimensions H M X 1 1/2 8 57/64 1 Min. F/C Start Sound Wiring Temp Rating Diag. Dim. .65 .28 74 74 .95 .95 1.28 1.28 < 1.7 < 1.7 < 20 < 20 50/10 50/10 A A 1 1 D2 D2 .65 .28 74 74 .95 .95 1.28 1.28 < 1.7 < 1.7 < 20 < 20 50/10 50/10 A A 1 1 D2 D2 Line H M L W Ballast Efficacy Crest THD Factor Factor % Black White Yellow Yellow BALLAST Blue Blue Red Red LAMP LAMP D Diagram 1 1 DIAGRAM PAGE 1-10 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) UNIVERSAL® ELECTROMAGNETIC BALLASTS T12 • 430 and 460 mA • 3´ and 4´ Lamp Applications High Output Lamps FOR F30T12, F30T12ES, and F40T12 LAMPS NOM Line Input Current Power Ballast Efficacy (Amps) (Watts) Factor Factor Ballast Crest THD Start Factor % Temp Min. F/C Sound Wiring Rating Diag. Dim. .66 .66 79 79 .90 .95 1.14 1.21 < 1.9 < 1.7 < 20 < 20 0/-18 60/15 A A 1 1 D4 D2 • .63 37 .72 1.95 < 1.7 < 10 50/10 A 8 D1 .58 .57 68 67 .86 .89 1.26 1.33 < 1.9 < 1.9 < 20 < 20 60/15 50/10 A A 1 1 D4 D2 • • • • .45 .19 .62 .75 .80 .34 .27 52 51 72 89 92 90 92 .95 .95 .85 .94 .88 .95 .95 1.83 1.86 1.18 1.06 0.96 1.06 1.03 < 1.7 < 1.7 < 1.7 < 1.7 < 1.7 < 1.7 < 1.7 < 20 < 20 < 20 < 20 < 20 < 20 < 20 50/10 50/10 50/10 50/10 0/-18 50/10 50/10 A A A A A A A 42 42 1 1 1 1 1 D2 D2 D2 D2 D4 D2 D2 .53 36 .61 1.69 < 1.7 < 20 50/10 A 8 D1 • ❉ For Residential Use Only ★ Not for use with “U” lamps ◆ Not for use with Energy Saver “U” lamps ✚ Operates at 50 or 60 Hz n For Replacement Only X For Distribution Only Overall Dimensions Mounting Dimensions Draw # L W H M X D1 6 7/16 1 7/8 1 1/2 6 D2 9 1/2 2 3/8 1 1/2 8 57/64 1 11/16 D4 9 1/2 2 3/8 1 11/16 8 57/64 1 11/16 WIRING DIAGRAMS Line Black White Yellow Yellow BALLAST Black White Blue Blue Red Red Blue BALLAST Red Red LAMP H LAMP M L W LAMP Diagram 1 DIAGRAM 1 D Line Use disconnect lampholder only Diagram 8 DIAGRAM 8 Line Black White Red Red BALLAST Blue Blue LAMP DIAGRAM 42 Diagram 42 PAGE 1-11 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electromagnetic Lamp Certification Line Catalog Qty. Descr. Volts Number F30T12 - High Power Factor 2 Rapid 120 W-589-D-TC-Pn • • 2 Rapid 120 573-L-TC-PX • • F30T12 - Normal Power Factor 1 Rapid 120 413-C-TC-P❉ • • F30T12ES - High Power Factor 2 Rapid 120 W-589-D-TC-Pn • • 2 Rapid 120 573-L-TC-PX • • F40T12- High Power Factor 1 Rapid 120 412-L-SLH-TC-P★n • • • • 1 Rapid 277 458-L-SLH-TC-P★n • • • • 2 Hybrid 120 420-L-TC-P◆ • • • • 2 Rapid 120 446-L-SLH-TC-Pn • • • • 2 Rapid 120 W-589-D-TC-Pn • • 2 Rapid 277 443-L-SLH-TC-Pn • • • • 2 Rapid 347 698-L-SLH-TC • • • • F40T12- Normal Power Factor 1 Rapid 120 413-C-TC-P❉ • • T12 High Output Lamps • 4´ Energy Saver Lamp Applications • Energy Efficient FOR F40T12ES, F40T12/U, F40T12ES/U, F48“ 25W/UTLS AND WORKLITE 25 LAMPS Fluorescent-Electromagnetic T8 U-Shaped Lamps Lamp Certification Line Catalog Qty. Descr. Volts Number F40T12ES - High Power Factor 1 Rapid 120 412-L-SLH-TC-P★n • • • • 1 Rapid 277 458-L-SLH-TC-P★n • • • • 2 Hybrid 120 420-L-TC-P◆ • • • • 2 Rapid 120 446-L-SLH-TC-Pn • • • • 2 Rapid 277 443-L-SLH-TC-Pn • • • • 2 Rapid 347 698-L-SLH-TC • • • F40T12ES - Normal Power Factor 1 Rapid 120 413-C-TC-P❉ • • F40T12 /U - High Power Factor 2 Hybrid 120 420-L-TC-P◆ • • • • 2 Rapid 120 446-L-SLH-TC-Pn • • • • • • 2 Rapid 120 W-589-D-TC-Pn 2 Rapid 277 443-L-SLH-TC-Pn • • • • 2 Rapid 347 698-L-SLH-TC • • • F40T12ES/U - High Power Factor 2 Rapid 120 446-L-SLH-TC-Pn • • • • 2 Rapid 277 443-L-SLH-TC-Pn • • • • 2 Rapid 347 698-L-SLH-TC • • • F48”25W/UTLS & WORKLITE - Normal Power Factor 1 Rapid 120 413-C-TC-P❉ • • ❉ ★ ◆ n UNIVERSAL® ELECTROMAGNETIC BALLASTS • 430 and 460 mA NOM Line Input Current Power Ballast Efficacy (Amps) (Watts) Factor Factor Ballast Crest THD Start Factor % Temp Min. F/C Sound Wiring Rating Diag. Dim. • • • • .38 .17 .50 .65 .28 .24 44 44 59 74 74 78 .88 .88 .80 .90 .90 .90 2.00 2.00 1.36 1.22 1.22 1.15 < 1.9 < 1.85 < 1.9 < 1.9 < 1.9 < 1.9 < 20 < 20 < 20 < 20 < 20 < 20 60/15 60/15 60/15 60/15 60/15 60/15 A A A A A A 42 42 1 1 1 1 D2 D2 D2 D2 D2 D2 • .61 33 .68 2.06 < 1.9 < 20 60/15 A 8 D1 • • .64 .76 .84 .34 .27 74 90 97 92 92 .83 .93 .92 .95 .93 1.12 1.03 0.95 1.03 1.01 < 1.7 < 1.7 < 1.7 < 1.7 < 1.7 < 32 < 20 < 20 < 20 < 20 50/10 50/10 0/-18 50/10 50/10 A A A A A 1 1 1 1 1 D2 D2 D4 D2 D2 • • .65 .28 .24 74 74 78 .90 .90 .90 1.22 1.22 1.15 < 1.9 < 1.9 < 1.9 < 20 < 20 < 20 60/15 60/15 60/15 A A A 1 1 1 D2 D2 D2 • .51 32 .90 2.79 < 1.7 < 20 50/10 A 8 D1 For Residential Use Only Not for use with “U” lamps Not for use with Energy Saver “U” lamps For Replacement Only Overall Dimensions Draw # L W D1 6 7/16 1 7/8 D2 9 1/2 2 3/8 11/16 WIRING DIAGRAMS Mounting Dimensions H M X 1 1/2 6 1 1/2 8 57/64 1 Line Black White Yellow Yellow BALLAST Black White Blue Blue Red Red Blue BALLAST Red Red LAMP H LAMP M L W LAMP Diagram 1 DIAGRAM 1 D Line Use disconnect lampholder only Diagram 8 DIAGRAM 8 Line Black White Red Red BALLAST Blue Blue LAMP Diagram 42 DIAGRAM 42 PAGE 1-12 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) UNIVERSAL® ELECTROMAGNETIC BALLASTS T12 HO • 800 mA • 2-3 1/2´ Lamp Applications • Standard & Weatherproof Models High Output Lamps FOR F24, F30, F36, F42 AND F48T12HO LAMPS F24T12HO - High Power Factor 2 Rapid 120 490-XLH-TC-P 2 Rapid 120 631-LH-TC-P❁ 2 Rapid 347 778-XLH-TC F36T12HO - High Power Factor 2 Rapid 120 490-XLH-TC-P 2 Rapid 120 631-LH-TC-P✪ 2 Rapid 347 778-XLH-TC F42T12HO - High Power Factor 2 Rapid 120 490-XLH-TC-P F48T12HO - High Power Factor 1 Rapid 120 481-LH-TC-P▼ 1 Rapid 120 490-XLH-TC-P▼ 1 Rapid 120 631-LH-TC-P▼ 1 Rapid 347 778-XLH-TC▼ 2 Rapid 120 490-XLH-TC-P 2 Rapid 120 631-LH-TC-P 2 Rapid 347 778-XLH-TC Input Power Ballast (Watts) Factor Line Current (Amps) Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. • • • • • .95 1.13 .31 103 100 103 .81 .83 .81 0.79 0.83 0.79 < 2.0 < 2.0 < 2.0 > 32 < 32 > 32 -20/-29 -20/-29 -20/-29 B B B 1 1 1 D7 D6 D7 • • • • • 1.06 1.20 .41 121 122 141 .84 .85 .80 0.69 0.69 0.57 < 2.0 < 1.9 < 2.0 < 32 < 20 < 32 50/10 -20/-29 -20/-29 B B B 1 1 1 D7 D6 D7 • • 1.12 130 .86 0.66 < 2.0 < 32 50/10 B 1 D7 • • • • • • • • • • • • .79 .82 1.05 .32 1.18 1.25 .42 82 82 82 83 139 137 139 .84 .81 .83 .79 .87 .85 .86 1.02 0.99 1.02 0.95 0.63 0.62 0.62 < 1.9 < 2.0 < 1.9 < 2.0 < 2.0 < 1.7 < 2.0 > 32 > 32 < 32 > 32 < 20 < 20 < 32 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 B B B B B B B 12 15 15 15 1 1 1 D7 D7 D6 D7 D7 D6 D7 ❁ Power Factor Corrected to 75% for (2) F24T12HO ✪ Power Factor Corrected to 85% for (2) F36T12HO ▼ Power Factor Corrected to >70% XFor Distribution Only See page 1-16 for Dimensions and Wiring Diagrams PAGE 1-13 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electromagnetic See page 1-3 for additional information on weatherproof applications. Lamp Certification Line Catalog NOM Qty. Descr. Volts Number T12 HO UNIVERSAL® ELECTROMAGNETIC BALLASTS • 800-840 mA • 4´-5´4´´ Lamp Applications High Output Lamps • Standard and Weatherproof Models Fluorescent-Electromagnetic FOR F48T12HOES, F60T12HO AND F64T12HO LAMPS Lamp Certification Line Catalog NOM Qty. Descr. Volts Number F48T12HOES - High Power Factor 1 Rapid 120 481-LH-TC-P▼ 1 Rapid 120 490-XLH-TC-P▼ 1 Rapid 120 631-LH-TC-P▼ 1 Rapid 347 778-XLH-TC▼ 2 Rapid 120 490-XLH-TC-P 2 Rapid 120 631-LH-TC-P 2 Rapid 347 778-XLH-TC F60T12HO - High Power Factor 1 Rapid 120 481-LH-TC-P 1 Rapid 120 490-XLH-TC-P 1 Rapid 120 631-LH-TC-P▼ 1 Rapid 347 778-XLH-TC▼ 2 Rapid 120 490-XLH-TC-P 2 Rapid 347 778-XLH-TC F64T12HO - High Power Factor 1 Rapid 120 481-LH-TC-P 1 Rapid 120 490-XLH-TC-P 1 Rapid 347 778-XLH-TC▼ 2 Rapid 120 490-XLH-TC-P 2 Rapid 347 778-XLH-TC ▼ Power Factor Corrected to >70% X For Distribution Only Input Power Ballast (Watts) Factor Line Current (Amps) Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. • • • • • • • • • • • • .77 .80 1.03 .31 1.07 1.15 .39 75 76 75 78 124 124 126 .79 .78 .77 .75 .83 .80 .81 1.05 1.03 1.03 0.97 0.67 0.64 0.64 < 1.9 < 2.0 < 1.9 < 2.0 < 2.0 < 1.9 < 2.0 > 32 > 32 < 32 > 32 < 32 < 20 < 32 60/15 60/15 60/15 60/15 60/15 60/15 60/15 B B B B B B B 12 15 15 15 1 1 1 D7 D7 D6 D7 D7 D6 D7 • • • • • • • • • • .86 .92 1.08 .34 1.42 .49 100 99 94 96 169 169 .87 .83 .85 .82 .89 .88 0.87 0.84 0.90 0.85 0.53 0.52 < 1.9 < 2.0 < 1.7 < 2.0 < 2.0 < 2.0 < 32 > 32 < 32 > 32 < 20 < 20 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 B B B B B B 12 15 15 15 1 1 D7 D7 D6 D7 D7 D7 • • • • • • • • .90 .93 .35 1.50 .52 102 101 103 178 178 .87 .84 .82 .89 .93 0.85 0.83 0.80 0.50 0.52 < 1.9 < 1.9 < 2.0 < 1.9 < 2.0 < 32 > 32 > 32 < 20 < 20 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 B B B B B 12 15 15 1 1 D7 D7 D7 D7 D7 See page 1-16 for Dimensions and Wiring Diagrams PAGE 1-14 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) UNIVERSAL® ELECTROMAGNETIC BALLASTS T12 HO • 800 - 840 mA • 6´ - 8´ Lamp Applications High Output Lamps • Standard, Weatherproof & Tanning Models FOR F72T12HO, F84T12HO, F96T12HO AND F96T12HOES LAMPS F72T12HO - High Power Factor 1 Rapid 120 481-LH-TC-P 1 Rapid 120 490-XLH-TC-P 1 Rapid 347 778-XLH-TC✜ 2 Rapid 120 480-SLH-TC-P 2 Rapid 120 480-XLH-TC-Pn 2 Rapid 120 490-XLH-TC-P 2 Rapid 277 487-SLH-TC-P 2 Rapid 277 487-XLH-TC-Pn 2 Rapid 347 778-XLH-TC F84T12HO - High Power Factor 1 Rapid 120 481-LH-TC-P 2 Rapid 120 480-SLH-TC-P 2 Rapid 120 480-XLH-TC-Pn 2 Rapid 277 487-SLH-TC-P 2 Rapid 277 487-XLH-TC-Pn F96T12HO - High Power Factor 1 Rapid 120 481-LH-TC-P 1 Rapid 120 490-XLH-TC-P 1 Rapid 347 778-XLH-TC 2 Rapid 120 480-SLH-TC-P 2 Rapid 120 480-XLH-TC-Pn 2 Rapid 277 487-SLH-TC-P 2 Rapid 277 487-XLH-TC-Pn F96T12HOES - High Power Factor 1 Rapid 120 481-LH-TC-P 1 Rapid 120 490-XLH-TC-P 1 Rapid 347 778-XLH-TC 2 Rapid 120 480-SLH-TC-P 2 Rapid 120 480-XLH-TC-Pn 2 Rapid 277 487-SLH-TC-P 2 Rapid 277 487-XLH-TC-Pn ✜ Power Factor Corrected to >85% nFor Replacement Only X For Distribution Only Input Power Ballast (Watts) Factor Line Current (Amps) Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. • • • • • • • • • • • • • • • • • • • • • • .92 .95 .35 1.69 1.69 1.50 .74 .78 .54 106 107 106 196 196 177 197 208 187 .89 .86 .84 .97 .97 .92 .96 .95 .95 0.84 0.80 0.79 0.49 0.49 0.52 0.48 0.46 0.51 < 1.9 < 2.0 < 2.0 < 1.9 < 1.9 < 1.7 < 1.7 < 1.7 < 1.7 < 32 > 32 > 32 < 20 < 20 < 10 < 20 < 20 < 10 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 B B B B B B B B B 12 15 15 1 1 1 1 1 1 D7 D7 D7 D7 D7 D7 D7 D7 D7 • • • • • • • • • • • • • • • • 1.02 1.87 1.98 .87 .89 119 220 235 235 244 .88 .93 .93 .97 .95 0.74 0.42 0.40 0.41 0.39 < 1.9 < 1.9 < 1.9 < 1.9 < 1.9 < 32 < 20 < 20 < 20 < 20 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 B B B B B 12 1 1 1 1 D7 D7 D7 D7 D7 • • • • • • • • • • • • • • • • • • • 1.16 1.10 .41 1.99 2.15 .87 .95 136 124 137 237 246 237 249 .91 .85 .83 .96 .96 .95 .97 0.67 0.65 0.71 0.41 0.39 0.40 0.39 < 1.9 < 2.0 < 2.0 < 1.7 < 1.7 < 1.7 < 1.7 < 20 < 20 < 32 < 10 < 10 < 10 < 10 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 B B B B B B B 12 15 15 1 1 1 1 D7 D7 D7 D7 D7 D7 D7 • • • • • • • • • • • • • • • • • • • .96 .94 .37 1.72 1.80 .75 .83 110 106 116 202 209 205 223 .84 .81 .83 .89 .89 .91 .92 0.77 0.76 0.71 0.44 0.43 0.44 0.41 < 1.9 < 2.0 < 2.0 < 1.9 < 1.9 < 1.9 < 1.9 < 32 < 32 < 32 < 20 < 20 < 20 < 20 60/15 60/15 60/15 60/15 60/15 60/15 60/15 B B B B B B B 12 15 15 1 1 1 1 D7 D7 D7 D7 D7 D7 D7 See page 1-16 for Dimensions and Wiring Diagrams PAGE 1-15 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electromagnetic See page 1-3 for additional information on weatherproof applications. Lamp Certification Line Catalog NOM Qty. Descr. Volts Number Fluorescent-Electromagnetic T12 HO & VHO UNIVERSAL® ELECTROMAGNETIC BALLASTS Overall Dimensions Mounting Dimensions Draw # L W H M X D6 11 3/4 3 1/8 1 25/32 11 9/64 2 D7 11 3/4 3 3/16 1 5/8 11 9/64 2 D8 14 5/16 3 3/16 2 5/8 13 3/4 2 D9 19 3/16 3 3/16 2 5/8 18 5/8 2 WIRING DIAGRAMS Line Black White Yellow Yellow BALLAST Blue Blue Red Red LAMP LAMP Diagram 1 H DIAGRAM 1 M L W D Line Black White Blue Blue BALLAST Red Red Black Red Red White BALLAST Yellow Yellow Blue Blue LAMP LAMP Diagram 12 DIAGRAM 12 Line INSULATE EACH YELLOW LEAD INDIVIDUALLY DIAGRAM 15 Diagram 15 PAGE 1-16 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) UNIVERSAL® ELECTROMAGNETIC BALLASTS T12 VHO • 1500 - 1580 mA • 4´ and 6´ VHO, SHO & PG Lamp Applications High Output Lamps FOR F72PG17, F72T12VHO, F96PG17, F96PG17ES, F96T12VHO AND F96T12VHOES LAMPS F72PG17 - High Power Factor 2 Rapid 120 930-K-TC-P❷X 2 Rapid 120 931-LH-TC-P①X 2 Rapid 277 937-K-TC-P❷X F72T12VHO - High Power Factor 2 Rapid 120 930-K-TC-P❷X 2 Rapid 120 931-LH-TC-P①X 2 Rapid 277 937-K-TC-P❷X F96PG17 - High Power Factor 2 Rapid 120 930-K-TC-P❷X 2 Rapid 120 931-LH-TC-P①X 2 Rapid 277 937-K-TC-P❷X F96PG17ES - High Power Factor 2 Rapid 120 931-LH-TC-PX F96T12VHO - High Power Factor 2 Rapid 120 930-K-TC-P❷X 2 Rapid 120 931-LH-TC-P①X 2 Rapid 277 937-LH-TC-P❷X F96T12VHOES - High Power Factor 2 Rapid 120 931-LH-TC-PX Input Power Ballast (Watts) Factor Line Current (Amps) Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. • • • • • • 3.05 2.77 1.26 360 303 341 .95 .82 .92 0.26 0.27 0.27 < 1.7 < 1.7 < 1.7 < 20 < 20 < 20 -20/-29 -20/-29 -20/-29 D D D 1 1 1 D8 D8 D8 • • • • • • 3.05 2.77 1.26 360 303 341 .95 .80 .91 0.26 0.26 0.27 < 1.7 < 1.7 < 1.7 < 20 < 20 < 20 -20/-29 -20/-29 -20/-29 D D D 1 1 1 D8 D8 D8 • • • • • • 3.83 3.25 1.61 446 380 429 .98 .83 .95 0.22 0.22 0.22 < 1.7 < 1.7 < 1.7 < 20 < 20 < 20 -20/-29 -20/-29 -20/-29 D D D 1 1 1 D8 D8 D8 • • 2.88 333 .75 0.22 < 1.7 < 32 60/15 D 1 D8 • • • • • • 4.10 3.83 1.64 482 431 450 .99 .93 .95 0.21 0.22 0.21 < 1.7 < 1.7 < 1.7 < 20 < 20 < 20 -20/-29 -20/-29 -20/-29 D D D 1 1 1 D8 D8 D8 • • 3.09 361 .83 0.23 < 1.7 < 20 60/15 D 1 D8 ❷ Cannot be used with T10 or T10J lamps ①May be used with equivalent T10 or T10J Lamps X For Distribution Only See page 1-18 for Dimensions and Wiring Diagrams PAGE 1-17 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electromagnetic Lamp Certification Line Catalog NOM Qty. Descr. Volts Number UNIVERSAL® ELECTROMAGNETIC BALLASTS • 430 mA • 20-40 Watt Lamp Applications CIRCLINE FOR 20, 22, 32 AND 40 WATT LAMPS Fluorescent-Electromagnetic Circline Lamps Lamp Certification Line Catalog NOM Qty. Descr. Volts Number FC6T9 (20 Watt) - Normal Power Factor 1 Preheat 120 200-C-S-P♣X 1 Rapid 120 547-RS-WS-TC-PX FC8T9 (22 Watt) - Normal Power Factor 1 Preheat 120 200-C-S-P♣X 1 Rapid 120 547-RS-WS-TC-P✩X FC12T9 (32 Watt) - High Power Factor 2 Rapid 120 W-589-D-TC-P❸n FC12T9 (32 Watt) - Normal Power Factor 1 Preheat 120 202-B-TC-P❶X 1 Preheat 120 202-SB-TC-P♣X 1 Rapid 120 445-RS-WS-TC-P✩X FC16T9 (40 Watt) - High Power Factor 2 Rapid 120 W-589-D-TC-P❸n FC16T9 (40 Watt) - Normal Power Factor 1 Rapid 120 445-RS-WS-TC-P✩X Line Current (Amps) Input Power Ballast (Watts) Factor Min. F/C Start Sound Wiring Temp Rating Diag. Ballast Efficacy Crest THD Factor Factor % Dim. • • • • .40 .64 29 27 1.01 .90 3.47 3.30 < 1.7 < 1.7 <10 < 10 50/10 50/10 A A 28 29 D11 D1 • • • • .24 .60 22 30 .93 .85 4.19 2.83 < 1.7 < 1.7 <10 < 10 50/10 50/10 A A 28 29 D11 D1 • • .64 76 .89 1.17 < 1.9 < 20 0/-18 A 1 D4 • • • • • • .67 .67 .60 37 37 35 .91 .91 .68 2.44 2.44 1.97 < 1.7 < 1.7 < 1.7 <10 <10 < 20 50/10 50/10 50/10 A A A 22 28 29 D11 D11 D1 • • .88 98 .95 0.96 < 1.7 < 20 0/-18 A 1 D4 • • .55 33 .60 1.83 < 1.7 < 20 50/10 A 29 D1 ✩ Also available in White Cans ♥ Only available in White Cans ♣Starter is built in as an integral component ❶ Requires Starter ❸ May be used with any combination of F30T12/RS, F40T12/RS, FC12T9/RS and FC16T9/RS nFor Replacement Only XFor Distribution Only Overall Dimensions Mounting Dimensions Draw # L W H M X D1 6 7/16 1 7/8 1 1/2 6 D4 9 1/2 2 3/8 1 11/16 8 57/64 1 11/16 WIRING DIAGRAMS Line Black White Yellow Yellow BALLAST S Blue Blue Red Red LAMP LAMP Blue White LAMP Black BALLAST DIAGRAM Diagram 1 1 Line H M L W D Line Black White Blue BALLAST Red White Line Black White Diagram 22 DIAGRAM 22 BALLAST Yellow Red Red Blue White LAMP Mount lamp within 1/2" of grounded metal reflector DIAGRAM Diagram 28 28 PAGE 1-18 Metal contacts lamp to fixture DIAGRAM Diagram 2929 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) UNIVERSAL® ELECTROMAGNETIC BALLASTS T12 • 425-440 mA • 2´-7´ Lamp Applications SLIMLINE Slimline Lamps • Slimline FOR F24 - F84T12 LAMPS ◗ Power Factor Corrected to >75% ❏ Use with any combination of F60T12 & F64T12 nFor Replacement Only Input Power Ballast (Watts) Factor Line Current (Amps) Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. .29 60 .96 1.60 < 1.85 < 32 32 / 0 B 40 D6 .70 .34 77 75 .95 .93 1.24 1.24 < 1.85 > 32 < 1.85 < 32 50/10 32 / 0 B B 39 40 D10 D12 .80 .37 94 94 .92 .92 0.98 0.98 < 1.85 < 20 < 1.85 < 32 50/10 32 / 0 B B 39 40 D10 D12 .74 .34 86 84 .93 .94 1.09 1.11 < 2.0 < 32 < 1.85 < 32 50/10 32 / 0 B B 39 40 D10 D12 .79 .35 95 95 .92 .96 0.89 1.01 < 1.85 < 20 < 1.85 < 32 50/10 32 / 0 B B 39 40 D10 D12 .72 .32 80 82 .91 .94 1.14 1.15 < 2.0 < 2.0 < 32 < 32 60/15 60/15 B B 39 40 D10 D12 .96 109 .84 0.77 < 1.85 < 32 0/-18 C 39 D6 1.05 119 .84 0.71 < 1.85 < 32 0/-18 C 39 D6 .72 .30 1.13 1.03 .49 .37 81 78 133 120 135 123 .95 .92 1.01 .82 .93 .91 1.17 1.18 0.76 0.69 0.69 0.74 < 1.85 < 1.85 < 1.85 < 1.85 < 1.85 < 1.85 < 32 < 32 < 20 < 32 < 20 < 32 0/-18 0/-18 50/10 0/-18 50/10 50/10 C C C C C C 34 34 39 39 40 65 D6 D6 D6 D6 D12 D12 .77 .33 1.26 .55 .42 89 86 143 150 141 .96 .94 .95 .95 .92 1.09 1.09 0.67 0.63 0.65 < 1.85 < 1.85 < 1.85 < 1.85 < 1.85 < 32 < 32 < 20 < 10 < 32 0/-18 0/-18 50/10 50/10 50/10 C C C C C 34 34 39 40 65 D6 D6 D6v D12 D12 See page 1-23 for Dimensions and Wiring Diagrams XFor Distribution Only PAGE 1-19 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electromagnetic Lamp Certification Line Catalog Qty. Descr. Volts Number NOM F24T12 - High Power Factor 2 Instant 277 532-BR-TC-P◗X • • F36T12 - High Power Factor 2 Instant 120 213-TC-PX • • • 2 Instant 277 532-BR-TC-P◗X • • F40T12 /IS - Bi Pin - High Power Factor 2 Instant 120 213-TC-PX • • • 2 Instant 277 532-BR-TC-PX • • F42T12 - High Power Factor 2 Instant 120 213-TC-PX • • • 2 Instant 277 532-BR-TC-PX • • F48T12 - High Power Factor 2 Instant 120 213-TC-PX • • • 2 Instant 277 532-BR-TC-PX • • F48T12ES - High Power Factor 2 Instant 120 213-TC-PX • • • 2 Instant 277 532-BR-TC-PX • • F60T12 - High Power Factor 2 Instant 120 881-BR-TC-P❏X • • F64T12 - High Power Factor 2 Instant 120 881-BR-TC-P❏X • • F72T12 - High Power Factor 1 Instant 120 822-BR-TC-P • • • 1 Instant 277 828-BR-TC-PX • • 2 Instant 120 806-SLH-TC-Pn • • • • • 2 Instant 120 881-BR-TC-PX • • 2 Instant 277 827-SLH-TC-Pn • • • • • 2 Instant 347 897-SLH-TCX • • • F84T12 - High Power Factor 1 Instant 120 822-BR-TC-P • • • 1 Instant 277 828-BR-TC-PX • • 2 Instant 120 806-SLH-TC-Pn • • • • • 2 Instant 277 827-SLH-TC-Pn • • • • • 2 Instant 347 897-SLH-TCX • • • T12 UNIVERSAL® ELECTROMAGNETIC BALLASTS • 425-440 mA SLIMLINE • 8´ Lamp Applications Slimline Lamps Fluorescent-Electromagnetic FOR F96T12 AND F96T12ES LAMPS Lamp Certification Line Catalog Qty. Descr. Volts Number NOM F96T12 - High Power Factor 1 Instant 120 822-BR-TC-P • • • 1 Instant 277 828-BR-TC-PX • • 2 Instant 120 806-SLH-TC-Pn • • • • • 2 Instant 277 827-SLH-TC-Pn • • • • • 2 Instant 347 897-SLH-TCX • • F96T12ES - High Power Factor 1 Instant 120 822-BR-TC-P • • • 1 Instant 277 828-BR-TC-PX • • 2 Instant 120 806-SLH-TC-Pn • • • • • 2 Instant 277 827-SLH-TC-Pn • • • • • • • 2 Instant 347 897-SLH-TCX Line Current (Amps) Input Power Ballast (Watts) Factor Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. .84 .35 1.41 .58 .45 96 93 165 158 151 .95 .93 .95 .93 .89 0.98 1.00 0.57 0.59 0.59 < 1.85 < 1.85 < 1.85 < 1.85 < 1.85 < 32 < 32 < 10 < 10 < 32 0/-18 0/-18 50/10 50/10 50/10 C C C C C 34 34 39 40 65 D6 D6 D6 D12 D12 .70 .30 1.13 .48 .38 79 79 133 132 121 .90 .96 .91 .89 .86 1.14 1.22 0.68 0.67 0.71 < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 < 32 < 32 < 20 < 20 < 32 60/15 60/15 60/15 60/15 60/15 C C C C C 34 34 39 40 65 D6 D6 D6 D12 D12 n For Replacement Only X For Distribution Only WIRING DIAGRAMS Overall Dimensions Mounting Dimensions Draw # L W H M X D6 11 3/4 3 1/8 1 25/32 11 9/64 2 D10 9 29/64 3 3/32 1 25/32 8 57/64 1 11/16 LAMP LAMP Line LAMP White Black H White Red Black BALLAST Red Blue Diagram 39 DIAGRAM 39 Line M L W BALLAST Diagram 34 DIAGRAM 34 D LAMP LAMP LAMP Brown Brown White Black BALLAST LAMP Yellow Yellow White Black Blue Red BALLAST Blue Red Line Line Diagram 40 40 DIAGRAM PAGE 1-20 Diagram 65 DIAGRAM 65 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) UNIVERSAL® ELECTROMAGNETIC BALLASTS PREHEAT/ TRIGGER • 4-13 Watt T5 Lamp Applications • 14 Watt T8 & T12 Applications High Output Lamps FOR F4, F6, F8, F13T5, F14T8 AND F14T12 LAMPS F6T5 - Normal Power Factor 1 Preheat 120 4105P❶ 1 Preheat 120 4105F2P❶ F8T5 - Normal Power Factor 1 Preheat 120 4105P❶ 1 Preheat 120 4105F2P❶ F14T8 - Normal Power Factor 1 Preheat 120 200-C-S-P♣X 1 Preheat 120 200-H2❶ F14T12 - High Power Factor 2 Preheat 120 564-L-TC-P 2 Preheat 277 554-L-TC-PX F14T12 - Normal Power Factor 1 Preheat 120 200-C-S-P♣X 1 Preheat 120 200-H2❶ 1 Preheat 120 546-B-TC-P♠X 2 Preheat 120 447-LR-VLH-TC-P❺ • • • • • • • • • • • • • • • • • • • • • • • Input Power Ballast (Watts) Factor Line Current (Amps) Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. .18 .18 9 9 1.00 1.00 11.11 11.11 < 1.5 < 1.5 10 10 50 50 A A 21 21 C1 B1 .17 .17 9.5 9.5 1.00 1.00 10.53 10.53 < 1.5 < 1.5 9 9 50 50 A A 21 21 C1 B1 • .42 .36 22 19 1.07 .99 4.89 5.15 < 1.7 < 1.7 <10 <10 50/10 50/10 A A 28 21 D11 E1 • .39 .17 45 45 .79 .79 1.75 1.76 < 1.7 < 1.9 <20 <20 50/10 50/10 A A 1 1 D2 D2 • • .43 .37 .66 .62 22 20 30 40 1.11 .98 .86 .77 4.96 4.85 2.87 1.95 < 1.7 < 1.7 < 1.7 < 1.7 <10 <10 <10 <20 50/10 50/10 50/10 50/10 A A A A 28 21 8 1 D11 E1 D1 D3 ❶ Requires Starter ♣ Starter is built in as an integral component ♠ Requires one circuit interrupting lamp holder ❺ Recommended for enclosed Fixtures Requiring “very low heat” ballasts XFor Distribution Only See page 1-24 for Dimensions and Wiring Diagrams PAGE 1-21 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electromagnetic Lamp Certification Line Catalog NOM Qty. Descr. Volts Number PREHEAT/ TRIGGER UNIVERSAL® ELECTROMAGNETIC BALLASTS • 15, 18 & 19 Watt T8 Lamp Applications High Output Lamps • 15 Watt T12 Lamp Applications Fluorescent-Electromagnetic FOR F15T8, F18T8, F19T8 AND F15T12 LAMPS Lamp Certification Line Catalog Qty. Descr. Volts Number NOM F15T8 - High Power Factor 2 Preheat 120 564-L-TC-P • • • 2 Preheat 277 554-L-TC-PX • • F15T8 - Normal Power Factor 1 Preheat 120 200-C-S-P♣X • • 1 Preheat 120 200-H2❶ • • • 1 Preheat 120 546-B-TC-P♠X • • • 1 Preheat 120 CF1320H2P❶ • • 2 Preheat 120 447-LR-TC-P • • 2 Preheat 120 447-LR-VLH-TC-P❺ • • F18T8 - Normal Power 1 Preheat 120 200-C-S-P♣X • • 1 Preheat 120 200-H2❶ • • • F19T8 - Normal Power 1 Preheat 120 200-C-S-P♣X • • 1 Preheat 120 200-H2❶ • • • F15T12 - High Power 2 Preheat 120 564-L-TC-P • • • 2 Preheat 277 554-L-TC-PX • • F15T12 - Normal Power 1 Preheat 120 200-C-S-P♣X • • 1 Preheat 120 200-H2❶ • • • 1 Preheat 120 546-B-TC-P♠X • • • 2 Preheat 120 447-LR-TC-P • • 2 Preheat 120 447-LR-VLH-TC-P❺ • • ♣ Starter is built in as an integral component ♠Requires one circuit interrupting lamp holder ❶Requires Starter ❺Recommended for enclosed Fixtures Requiring “very low heat” ballasts X For Distribution Only Input Power Ballast (Watts) Factor Line Current (Amps) Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. .47 .20 51 51 .91 .89 1.78 1.76 < 1.7 < 1.9 <32 <20 50/10 50/10 A A 1 1 D2 D2 .36 .32 .55 .26 .50 .53 22 20 25 17 39 38 1.05 1.05 .89 .75 .75 .76 4.86 5.13 3.50 4.55 1.92 2.02 < 1.7 < 1.7 < 1.7 < 1.7 < 1.7 < 1.7 <10 <10 <10 <15 <20 <20 50/10 50/10 50/10 50/10 50/10 50/10 A A A A A A 28 21 8 21 1 1 D11 E1 D1 E2 D3 D3 .33 .28 21 19 .91 .80 4.31 4.29 < 1.7 < 1.7 <10 <10 50/10 50/10 A A 28 21 D11 E1 .31 .26 21 18 .91 .80 4.28 4.33 < 1.7 < 1.7 <10 <10 50/10 50/10 A A 28 21 D11 E1 .43 .20 44 49 .85 .87 1.91 1.78 < 1.7 < 1.9 <20 <20 50/10 50/10 A A 1 1 D2 D2 .41 .44 .61 .56 .58 23 21 30 42 40 1.20 1.08 .96 .80 .77 5.26 5.19 3.23 1.90 1.93 < 1.7 < 1.7 < 1.7 < 1.7 < 1.7 <10 <10 <10 <20 <10 50/10 50/10 50/10 50/10 50/10 A A A A A 28 21 8 1 1 D11 E1 D1 D3 D3 See page 1-24 for Dimensions and Wiring Diagrams PAGE 1-22 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) UNIVERSAL® ELECTROMAGNETIC BALLASTS PREHEAT/ TRIGGER • 20-40 Watt T12 Lamp Applications • 30 Watt T8 Lamp Applications High Output Lamps 60Hz FOR F20, F25, F30, F40T12 AND F30T8 LAMPS Line Current (Amps) Input Power Ballast (Watts) Factor Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. .51 .22 55 55 .85 .86 1.55 1.55 < 1.7 < 1.7 <20 <20 50/10 50/10 A A 1 1 D2 D2 .35 .30 .58 .26 .43 .42 23 20 29 17 37 35 .95 .83 .82 .75 .56 .55 4.15 4.15 2.83 4.55 1.51 1.57 < 1.7 < 1.7 < 1.7 < 1.7 < 1.7 < 1.7 <10 <10 <10 <15 <20 <20 50/10 50/10 50/10 50/10 50/10 50/10 A A A A A A 28 21 8 21 1 1 D11 E1 D1 E2 D3 D3 .62 .62 37 39 .97 2.97 2.62 7.62 < 1.7 < 1.7 <10 <10 50/10 50/10 A A 22 28 D11 D11 .68 .68 37 37 .85 .85 2.28 2.28 < 1.7 < 1.7 <10 <10 50/10 50/10 A A 22 28 D11 D11 .60 .60 39 39 .77 .77 1.99 1.99 < 1.7 < 1.7 <10 <10 50/10 50/10 A A 22 28 D11 D11 .68 .68 37 37 .82 .82 2.22 2.22 < 1.9 < 1.9 <10 <10 60/15 60/15 A A 22 28 D11 D11 See page 1-24 for Dimensions and Wiring Diagrams ♣ Starter is built in as an integral component ❶ Requires Starter ♠ Requires one circuit interrupting lamp holder ❺ Recommended for enclosed Fixtures Requiring “very low heat” ballasts X For Distribution Only PAGE 1-23 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electromagnetic Lamp Certification Line Catalog Qty. Descr. Volts Number NOM F20T12 - High Power Factor 2 Preheat 120 564-L-TC-P • • • 2 Preheat 277 554-L-TC-PX • • F20T12 - Normal Power Factor 1 Preheat 120 200-C-S-P♣X • • 1 Preheat 120 200-H2❶ • • • 1 Preheat 120 546-B-TC-P♠X • • • 1 Preheat 120 CF1320H2P❶ • • 2 Preheat 120 447-LR-TC-P • • 2 Preheat 120 447-LR-VLH-TC-P❺ • • F30T8 - Normal Power Factor 1 Preheat 120 202-B-TC-P❶X • • 1 Preheat 120 202-SB-TC-P♣X • • F30T12 - Normal Power Factor 1 Preheat/RS 120 202-B-TC-P❶X • • 1 Preheat/RS 120 202-SB-TC-P♣X • • F40T12 - Normal Power Factor 1 Preheat/RS 120 202-B-TC-P❶X • • 1 Preheat/RS 120 202-SB-TC-P ♣X • • F40T12ES - Normal Power Factor 1 Preheat/RS 120 202-B-TC-P❶X • • 1 Preheat/RS 120 202-SB-TC-P♣X • • Fluorescent-Electromagnetic PREHEAT/ TRIGGER Overall Dimensions Draw # L W B1 2 3/8 27/32 C1 2 3/4 1 27/32 D1 6 7/16 1 7/8 D2 9 1/2 2 3/8 11/16 D3 6 19/32 2 3/8 D11 6 7/16 1 7/8 E1 3 1/16 1 25/32 UNIVERSAL® ELECTROMAGNETIC BALLASTS Mounting Dimensions H M X 1 13/32 2 1 3/32 2 13/32 1 1/2 6 1 1/2 8 57/64 1 1 1/2 1 5/16 1 5/16 6 6 2 3/4 WIRING DIAGRAMS Black White Yellow Yellow Line BALLAST Black White Blue Blue Red Red Blue BALLAST Red Red LAMP - LAMP LAMP Diagram 1 DIAGRAM 1 Line Use disconnect lampholder only Diagram 8 DIAGRAM 8 M W A H S S S LAMP LAMP C L Black B L M H M L D Blue White Black Black BALLAST W H W BALLAST M L Line Line Diagram 21 DIAGRAM 21 Diagram 22 DIAGRAM 22 3/32" Slots E Line Black White Blue BALLAST Red White Yellow LAMP Mount lamp within 1/2" of grounded metal reflector DIAGRAM Diagram 2828 PAGE 1-24 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) UNIVERSAL® ELECTROMAGNETIC BALLASTS • 14-20 Watt EXPORT • Preheat/Trigger High Output Lamps • T12/T8 FOR 14 - 20 WATT, T8 AND T12 LAMPS F14T12 - High Power Factor 2 Trigger 220/60Hz 567-L-TC F15T12 - High Power Factor 2 Trigger 220/60Hz 567-L-TC F15T8 - High Power Factor 2 Trigger 220/60Hz 567-L-TC F20T12 - High Power Factor 2 Trigger 127/60Hz 597-L-TC-P❾ 2 Trigger 220/60Hz 567-L-TC Input Power Ballast (Watts) Factor Line Current (Amps) Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. • .22 44 .76 1.74 < 1.9 < 20 50/10 A 1 D2 • .24 47 .85 1.81 < 1.9 < 20 50/10 A 1 D2 • .25 49 .86 1.77 < 1.9 < 32 50/10 A 1 D2 • • • .45 .26 55 53 .88 .83 1.60 1.55 < 1.7 < 1.7 < 15 < 20 50/10 50/10 A A 1 1 D2 D2 ❾ May also be used with F14T12, F15T8 and F15T12 Lamps Overall Dimensions Draw # L W D2 9 1/2 2 3/8 Mounting Dimensions H M X 1 1/2 8 57/64 1 WIRING DIAGRAMS Line H BALLAST Blue Blue Red Red LAMP M L W Black White Yellow Yellow LAMP D Diagram 1 DIAGRAM 1 PAGE 1-25 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electromagnetic Lamp Certification Line Catalog NOM Qty. Descr. Volts Number UNIVERSAL® ELECTROMAGNETIC BALLASTS • 430-460 mA EXPORT • Rapid Start T12 High Output Lamps FOR F30T12, F30T12ES, F40T12, F40T12/U, F40T12ES AND F40T12ES/U LAMPS Fluorescent-Electromagnetic T8 U-Shaped Lamps Lamp Certification Line Catalog Qty. Descr. Volts Number NOM F40T12 - High Power Factor 2 Rapid 120/60Hz 446-LR-TC-P➐ • • • 2 Rapid 127/60Hz 595-L-TC-P❿ • • 2 Rapid 220/60Hz 540-L-TC-P • 2 Rapid 277/60Hz 808-BR-TC-P➐ • • • F40T12/U - High Power Factor 1 Rapid 120/60Hz 412-L-TC-P➐ • • 2 Rapid 120/60Hz 446-LR-TC-P➐ • • • F40T12ES - High Power Factor 1 Rapid 120/60Hz 412-L-TC-P➐ • • 2 Rapid 120/60Hz 446-LR-TC-P➐ • • • 2 Rapid 220/60Hz 540-L-TC-P • 2 Rapid 277/60Hz 443-L-TC-P➐ • • • F40T12ES/U - High Power Factor 2 Rapid 120/60Hz 446-LR-TC-P➐ • • • ❍ Power Factor Corrected to >80% ✜ Power Factor Corrected to >85% ➐ For Export Only-may not be purchased for use in the USA For Distribution Only Overall Dimensions Draw # L W D2 9 1/2 2 3/8 Mounting Dimensions H M X 1 1/2 8 57/64 1 Line Current (Amps) Input Power Ballast (Watts) Factor Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. .77 .70 .42 .36 91 87 90 96 .93 .88 .91 .94 1.02 1.01 1.01 0.97 <1.7 < 1.7 <1.7 < 1.7 <20 < 20 <20 < 20 50/10 50/10 50/10 50/10 A A A A 1 1 1 1 D2 D2 D2 D2 .48 .77 57 91 .95 .91 1.67 1.00 < 1.7 < 1.7 < 20 < 20 60/15 50/10 A A 42 1 D2 D2 .44 .66 .36 .32 51 75 75 82 .90 .86 .86 .88 1.76 1.15 1.15 1.08 < 1.7 < 1.9 <1.9 < 1.9 < 20 < 20 <20 < 20 50/10 60/15 60/15 60/15 A A A A 42 1 1 1 D2 D2 D2 D2 .66 75 .86 1.15 < 1.9 < 20 60/15 A 1 D2 ❿May also be used with F40T12ES Lamps ■For Replacement Only ✠For Distribution Only WIRING DIAGRAMS Line Black White Yellow Yellow BALLAST Blue Blue Red Red LAMP H LAMP DIAGRAM Diagram 1 1 M L W D Line Black White Red Red BALLAST Blue Blue LAMP Diagram 4242 DIAGRAM PAGE 1-26 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) UNIVERSAL® ELECTROMAGNETIC BALLASTS • 430 mA EXPORT • Rapid Start High Output Lamps • Continuous Dimming FOR F30T12 AND F40T12 LAMPS Input Power Ballast (Watts) Factor Line Current (Amps) Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. .85 .68 94 35 .88 .20 0.94 .57 < 1.7 < 1.7 < 20 < 32 50/10 50/10 A A 18 18 D5 D5 .87 .58 83 27 .89 .21 1.07 .77 < 1.7 < 1.9 < 20 < 32 50/10 50/10 A A 18 18 D5 D5 ♠ Requires one circuit interrupting lamp holder ✝ Requires two circuit interrupting lamp holder ➑ UL component recognized for use with specific Dimming Controls ➁ Power Factor Corrected to <60% ➂ Power Factor Corrected to >60% ✠ For Distribution Only Overall Dimensions Draw # L W D5 16 3/8 2 3/8 WIRING DIAGRAMS Mounting Dimensions H M X 1 1/2 15 25/32 1 DIMMER Black White H Blue/White Blue BALLAST Brown Yellow Yellow Red Red M L W LAMP D Black LAMP White Line Use disconnect lampholder only Diagram DIAGRAM 1818 Ballast must be grounded. Install in accordance with the national Electric Code WARNING External fuses should not be used with 277-volt dimming ballasts. CAUTION The control circuit line will carry approximately 0.375 amps per 40-watt lamps (and approximately 0.41 amps per 30-watt lamp). This means that the control circuit attached to the ballast brown wire must be sized appropriately. Please note that the ampacity of the control line is approximately double the ampacity requirement of the line when 277-volt dimming ballasts are used. When 120-volt ballasts are used, the ampacity requirement of the control lead is slightly lower than the line current. PAGE 1-27 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electromagnetic Lamp Certification Line Catalog NOM Qty. Descr. Volts Number F40T12 - High Power Factor 2 @ 100% 120 502-A-TC-P✝➑✠ • • 2 @ 20% 120 502-A-TC-P✝➑✠ • • F30T12 - Corrected Power Factor 2 @ 100% 120 502-A-TC-P➑➂✠ • • 2 @ 20% 120 502-A-TC-P➑➁✠ • • UNIVERSAL® ELECTROMAGNETIC BALLASTS • 425-440 mA EXPORT • 4´-8´ Lamp Applications High Output Lamps • T12 Slimline • Instant Start Fluorescent-Electromagnetic Slimline Lamps Lamp Certification Line Catalog Qty. Descr. Volts Number NOM F64T12 - High Power Factor 2 Instant 120/60Hz 806-BR-TC-P • • F72T12 - High Power Factor 2 Instant 120/60Hz 806-BR-TC-P➐ • • 2 Instant 220/60Hz 808-BR-TC-P❍ • F84T12 - High Power Factor 2 Instant 120/60Hz 806-BR-TC-P➐ • • 2 Instant 220/60Hz 808-BR-TC-P • F96T12 - High Power Factor 2 Instant 120/60Hz 806-BR-TC-P➐ • • 2 Instant 220/60Hz 808-BR-TC-P✜ • • F96T12ES - High Power Factor 2 Instant 120/60Hz 806-BR-TC-P➐ • • 2 Instant 220/60Hz 808-BR-TC-P◗ • • 2 Instant 127/60Hz 831-TC • FOR F64, F72, F84, F96T12 AND F96T12ES LAMPS Line Current (Amps) Input Power Ballast (Watts) Factor Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. 1.05 124 1.05 0.84 <1.85 <20 50/10 C 39 D12 1.15 .73 131 134 .90 .93 0.69 0.69 < 1.85 < 32 < 1.85 < 32 50/10 50/10 C C 39 39 D12 D12 1.29 .77 149 152 .92 .95 0.62 0.63 < 1.85 < 32 < 1.85 < 32 50/10 50/10 C C 39 39 D12 D12 1.40 .85 162 165 .89 .92 0.55 0.55 < 1.85 < 32 < 1.85 < 32 50/10 50/10 C C 39 39 D12 D12 1.16 .76 1.07 129 130 124 .86 .86 .68 0.67 0.66 0.55 < 2.0 < 32 < 2.0 < 32 < 1.85 < 25 60/15 60/15 50/10 C C B 39 39 39 D12 D12 D10 ◗ Power Factor Corrected to >75% ❍ Power Factor Corrected to >80% ✜ Power Factor Corrected to >85% ➐ For Export Only-may not be purchased for use in the USA XFor Distribution Only Overall Dimensions Mounting Dimensions Draw # L W H M X D10 9 29/64 3 3/32 1 25/32 8 57/64 1 11/16 WIRING DIAGRAMS LAMP Line LAMP White H Black M L W BALLAST Red Blue Diagram 39 DIAGRAM 39 D PAGE 1-28 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) UNIVERSAL® ELECTROMAGNETIC BALLASTS • 430-460 mA High HighOutput OutputLamps Lamps FOR F30T12, F30T12ES, F40T12, F40T12/U, F40T12ES AND F40T12ES/U LAMPS Slimline Lamps T8 U-Shaped Lamps ❍ Power Factor Corrected to >80% ✜ Power Factor Corrected to >85% ➐ For Export Only-may not be purchased for use in the USA For Distribution Only Overall Dimensions Draw # L W D1 6 7/16 1 7/8 D2 9 1/2 2 3/8 Mounting Dimensions H M X 1 1/2 6 1 1/2 8 57/64 1 Input Power Ballast (Watts) Factor Line Current (Amps) Min. F/C Start Sound Wiring Temp Rating Diag. Ballast Efficacy Crest THD Factor Factor % Dim. .77 .70 .42 .36 91 87 90 96 .93 .88 .91 .94 1.02 1.01 1.01 0.97 <1.7 < 1.7 <1.7 < 1.7 <20 < 20 <20 < 20 50/10 50/10 50/10 50/10 A A A A 1 1 1 1 D2 D2 D2 D2 .48 .77 57 91 .95 .91 1.67 1.00 < 1.7 < 1.7 < 20 < 20 60/15 50/10 A A 42 1 D2 D2 .44 .66 .36 .32 51 75 75 82 .90 .86 .86 .88 1.76 1.15 1.15 1.08 < 1.7 < 1.9 <1.9 < 1.9 < 20 < 20 <20 < 20 50/10 60/15 60/15 60/15 A A A A 42 1 1 1 D2 D2 D2 D2 .66 75 .86 1.15 < 1.9 < 20 60/15 A 1 D2 ❿May also be used with F40T12ES Lamps ■For Replacement Only ✠For Distribution Only WIRING DIAGRAMS Line Black White Yellow Yellow Blue Blue Red Red BALLAST LAMP H LAMP DIAGRAM Diagram 1 1 M L W Black/White D White BALLAST Blue LAMP Diagram 14 Line DIAGRAM 14 PAGE 1-29 Red Red Line Black White Red Red BALLAST Blue Blue LAMP Diagram 4242 DIAGRAM FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electromagnetic Lamp Certification Line Catalog Qty. Descr. Volts Number NOM F40T12 - High Power Factor 2 Rapid 120/60Hz 446-LR-TC-P➐ • • • 2 Rapid 127/60Hz 595-L-TC-P❿ • • 2 Rapid 220/60Hz 540-L-TC-P • 2 Rapid 277/60Hz 808-BR-TC-P➐ • • • F40T12/U - High Power Factor 1 Rapid 120/60Hz 412-L-TC-P➐ • • 2 Rapid 120/60Hz 446-LR-TC-P➐ • • • F40T12ES - High Power Factor 1 Rapid 120/60Hz 412-L-TC-P➐ • • 2 Rapid 120/60Hz 446-LR-TC-P➐ • • • 2 Rapid 220/60Hz 540-L-TC-P • 2 Rapid 277/60Hz 443-L-TC-P➐ • • • F40T12ES/U - High Power Factor 2 Rapid 120/60Hz 446-LR-TC-P➐ • • • EXPORT • Rapid Start T12 UNIVERSAL® ELECTROMAGNETIC BALLASTS • 425-440 mA EXPORT • 4´-8´ Lamp Applications High Output Lamps • T12 Slimline • Instant Start Fluorescent-Electromagnetic Slimline Lamps Lamp Certification Line Catalog Qty. Descr. Volts Number NOM F64T12 - High Power Factor 2 Instant 120/60Hz 806-BR-TC-P • • F72T12 - High Power Factor 2 Instant 120/60Hz 806-BR-TC-P➐ • • 2 Instant 220/60Hz 808-BR-TC-P❍ • F84T12 - High Power Factor 2 Instant 120/60Hz 806-BR-TC-P➐ • • 2 Instant 220/60Hz 808-BR-TC-P • F96T12 - High Power Factor 2 Instant 120/60Hz 806-BR-TC-P➐ • • 2 Instant 220/60Hz 808-BR-TC-P✜ • • F96T12ES - High Power Factor 2 Instant 120/60Hz 806-BR-TC-P➐ • • 2 Instant 220/60Hz 808-BR-TC-P◗ • • 2 Instant 127/60Hz 831-TC • FOR F64, F72, F84, F96T12 AND F96T12ES LAMPS Line Current (Amps) Input Power Ballast (Watts) Factor Ballast Efficacy Crest THD Factor Factor % Min. F/C Start Sound Wiring Temp Rating Diag. Dim. 1.05 124 1.05 0.84 <1.85 <20 50/10 C 39 D12 1.15 .73 131 134 .90 .93 0.69 0.69 < 1.85 < 32 < 1.85 < 32 50/10 50/10 C C 39 39 D12 D12 1.29 .77 149 152 .92 .95 0.62 0.63 < 1.85 < 32 < 1.85 < 32 50/10 50/10 C C 39 39 D12 D12 1.40 .85 162 165 .89 .92 0.55 0.55 < 1.85 < 32 < 1.85 < 32 50/10 50/10 C C 39 39 D12 D12 1.16 .76 1.07 129 130 124 .86 .86 .68 0.67 0.66 0.55 < 2.0 < 32 < 2.0 < 32 < 1.85 < 25 60/15 60/15 50/10 C C B 39 39 39 D12 D12 D10 ◗ Power Factor Corrected to >75% ❍ Power Factor Corrected to >80% ✜ Power Factor Corrected to >85% ➐ For Export Only-may not be purchased for use in the USA XFor Distribution Only Overall Dimensions Mounting Dimensions Draw # L W H M X D6 11 3/4 3 1/8 1 25/32 11 9/64 2 D10 9 29/64 3 3/32 1 25/32 8 57/64 1 11/16 WIRING DIAGRAMS LAMP White H BALLAST Black M L W Red Line Diagram 34 DIAGRAM 34 D LAMP Line LAMP White Black BALLAST Red Blue Diagram 39 DIAGRAM 39 PAGE 1-30 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) UNIVERSAL® ELECTROMAGNETIC BALLASTS • 430 mA DIMMING • Rapid Start High Output Lamps • Continuous Dimming FOR F30T12 AND F40T12 LAMPS Input Power Ballast (Watts) Factor Line Current (Amps) Min. F/C Start Sound Wiring Temp Rating Diag. Ballast Efficacy Crest THD Factor Factor % Fluorescent-Electromagnetic Lamp Certification Line Catalog NOM Qty. Descr. Volts Number F40T12 - High Power Factor 2 @ 100% 120 502-A-TC-P✝➑✠ • • 2 @ 20% 120 502-A-TC-P✝➑✠ • • 2 @ 100% 277 678-A-TC-P✝➑✠ • • 2 @ 20% 277 678-A-TC-P✝➑✠ • • F30T12 - Corrected Power Factor 2 @ 100% 120 502-A-TC-P➑➂✠ • • 2 @ 20% 120 502-A-TC-P➑➁✠ • • 2 @ 100% 277 678-A-TC-P➑➂✠ • • 2 @ 20% 277 678-A-TC-P✝➑➁✠ • • Dim. .85 .68 .39 .34 94 35 100 30 .88 .20 .88 .20 0.94 .57 0.94 .67 < 1.7 < 1.7 < 1.7 < 1.7 < 20 < 32 < 32 < 32 50/10 50/10 50/10 50/10 A A A A 18 18 16 16 D5 D5 D5 D5 .87 .58 .85 .68 83 27 96 33 .89 .21 .90 .23 1.07 .77 0.93 .70 < 1.7 < 1.9 < 1.7 < 1.7 < 20 < 32 < 32 < 32 50/10 50/10 50/10 50/10 A A A A 18 18 16 16 D5 D5 D5 D5 ♠ Requires one circuit interrupting lamp holder ✝ Requires two circuit interrupting lamp holder ➑ UL component recognized for use with specific Dimming Controls ➁ Power Factor Corrected to <60% ➂ Power Factor Corrected to >60% ✠ For Distribution Only Overall Dimensions Draw # L W D2 9 1/2 2 3/8 11/16 WIRING DIAGRAMS Mounting Dimensions H M X 1 1/2 8 57/64 1 DIMMER DIMMER Black/White White H Black White Red/White Blue/White Blue Red/White Line BALLAST Blue Red Red BALLAST Red M L W Brown Yellow Yellow Red LAMP LAMP D LAMP Use disconnect lampholder only Line Use disconnect lampholder only Diagram 9 DIAGRAM 9 WARNING External fuses should not be used with 277-volt dimming ballasts. Diagram 16 16 DIAGRAM DIMMER Black White Blue/White Blue BALLAST Black White Blue/White Blue/White Blue Yellow Yellow Red Red LAMP White Line Use disconnect lampholder only Diagram 18 Ballast must be grounded. Install in accordance with the national Electric Code PAGE 1-31 DIAGRAM 18 BALLAST Brown Red Red LAMP LAMP Black CAUTION The control circuit line will carry approximately 0.375 amps per 40-watt lamps (and approximately 0.41 amps per 30-watt lamp). This means that the control circuit attached to the ballast brown wire must be sized appropriately. Please note that the ampacity of the control line is approximately double the ampacity requirement of the line when 277-volt dimming ballasts are used. When 120-volt ballasts are used, the ampacity requirement of the control lead is slightly lower than the line current. DIMMER Brown Line Use disconnect lampholder only Diagram 19 DIAGRAM 19 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Electronic Fluorescent Ballasts A Complete Range of Solutions — From The Name You Trust For more than 30 years, the lighting industry has relied on our TRIAD® brand for the most specified, most installed, most reliable electronic ballasts in the business. The TRIAD® line offers advantages like installerfriendly universal input voltage, which ensures that you have the right voltage ballast every time. We’re also the industry leader in low profile design lightweight, space-saving ballasts that offer the same footprint and wiring as conventional ballasts. And our AccuStart™ ballasts feature programmed rapid start technology that dramatically enhances lamp life. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group Fluorescent-Electronic Fluorescent-Electronic Universal is the leader in energy saving electronic ballasts. Product Overview Setting The Pace In T8 Technology Universal Lighting keeps pushing the frontier of T8 technology with innovative products that deliver dramatic energy savings, greater fixture design flexibility, longer lamp life and installation ease. You can count on Universal for some of the industry’s smallest, lightest and most hassle-free T8 ballasts. Universal Voltage Low Profile High Performance (HP-A and HP-B) Our low profile High Performance ballasts with THD<10% offer the convenience of universal input voltage (108 - 305 volts) as a standard feature. Universal input is “installer-friendly” - ensuring that you have the right voltage ballast every time. Our low profile models also feature a remarkably small package and cross section (1.0”H x 1.5”W) for greater flexibility in fixture design. Since the mounting and wiring footprints are the same as a standard size ballast, our low profile HP models will easily retrofit into any T12 or T8 fixture. High Efficiency Lamp/Ballast System The High Efficiency Lamp/Ballast System is the most significant advancement in linear fluorescent energy savings in more than a quarter century. The system delivers up to 40% energy savings compared to conventional magnetic T12 energy-saving systems and up to 11% versus standard electronic T8 systems. Our High Efficiency ballast is designed to operate any lamp manufacturer’s F32T8/ES energy-saving lamp or standard F32T8 lamp. There are two options: - EL suffix denotes .77 ballast factor - HE suffix denotes .87 ballast factor - HEH suffix denotes 1.18 ballast factor AccuStart® AccuStart® ballasts are ideal for frequently switched applications or as a rapid start alternative. They incorporate programmed rapid start technology to properly heat the lamp filaments, which yields an increase in lamp life up to 50%. The 1-4 lamp models offer universal input voltage - an industry exclusive. Fluorescent-Electronic T8 Super Low Profile Our T8 super low profile models offer maximum fixture flexibility. They’re ideal for pendant mount and other specialty lighting applications. They feature a small cross section (1.0”H x 1.18”W) and low profile dimensions for indirect/direct fixtures, plus installer-friendly universal input voltage (108 - 305 volts). Low Power (L-A) Family of Low Profile Ballasts. AccuStart® ballasts for frequently switched applications. PAGE 2-2 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Product Overview Low Power (L-A) The L-A Series ballasts offer the option of a .78 ballast factor for maximum energy savings. They feature space-saving low profile design. The 2- to 4-lamp models are ideal for retrofitting energysaving T12 lamps - and offer parallel lamp operation and THD<20%. Low Profile Reduced Harmonic (RH-A) Our low profile RH ballasts are over 45% smaller and 30% lighter. They feature a space-saving package and cross section (1.18” H x 1.7”W) for greater flexibility in fixture design. The 1- to 4-lamp model features parallel lamp operation, with standard mounting footprint and wiring for ease of replacement. They offer high efficiency performance with THD<20%. Reduced Harmonic High Output (RHH and RHH-A) These ballasts deliver the maximum light output by operating lamps at their rated current of 265mA without compromising lamp life. They feature a 1.18 ballast factor versus the industry standard .88 to provide lighting design flexibility. T5 Ballasts For Indirect And High-End Architectural Applications T5 systems are gaining greater popularity for high-end architectural applications. Universal Lighting gives you a wide range of T5 solutions, from 14 to 54 watts. Our T5 ballasts operate multiple (1 or 2) F35T5, F28T5, F21T5 and F14T5 lamps. Additionally, our T5HO ballasts operate multiple (1 or 2) F54T5HO, F39T5HO and F24T5HO lamps. Moreover, they make your life easier with standard features that include universal input voltage (108 - 305 volts), programmed rapid start technology for longer lamp life and end of lamp life shutdown circuit with auto-reset. T5 Standard Output Our standard output T5 ballasts support multiple lamp operation (including 14-, 21-, 28-, and 35-watt lamps). They’re ideal for indirect pendant mount, surface mount, cove, undercabinet or task lighting. With a small cross section (1.0”H x 1.18”W), our T5 models give you more options for slim fixture design. Standard features include universal input voltage, end-of-lamp-life shutdown circuit and programmed rapid start technology. T5 High Output Universal’s high output T5 ballasts support 24-, 39- and 54-watt lamps. They offer the same standard features and compact dimensions as our T5 standard output line - and they’re also wellsuited to applications where space is at a premium, including slim pendant mounted fixtures, cove and task lighting. Fluorescent-Electronic Family of Universal HP Ballasts. Flexible Fixture design options for T5 and T5HO lamps. PAGE 2-3 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Application And Operating Information SAFETY NEC & UL Requirements Ballast installation presents the possibility of exposure to potentially hazardous voltages and should be performed only by qualified personnel. All installation, inspection and maintenance should be performed only with power to the fixture turned off. Additionally, all fixtures and ballasts must be installed and operated in compliance with the National Electrical Code, Underwriters Laboratories Inc. (UL) requirements, and all local applicable codes and regulations. Polarity Polarity refers to the proper connection of ballast lead wires to line wires. To aid you in making a correct installation, Universal ballast leads are color-coded for easy identification. The WHITE ballast lead is to be connected to the neutral (grounded) and the BLACK (or black with white tracer) lead always to the phase (“hot”) line wire. Systems where neither of the line wires are at ground potential require specially designed ballasts. A change in polarity may result in the voltage from the lead to the ground exceeding UL-specified limits. In some types of ballasts, a change in polarity may decrease voltage from the lead to the ground, thereby impeding the starting dependability of the ballast. Grounding Ballast cases and fixtures must always be grounded. The ballast case may be grounded to the fixture or otherwise grounded. It could be hazardous to make contact with an ungrounded fixture or ballast when in operation. Neglecting to properly ground the ballast and fixture combination may also result in failure of certain lamps to start or for unacceptable levels of electromagnetic noise to be conducted onto the power lines. Operating Line Voltage Limits To receive the full benefits of rated lamp output and to prolong ballast life, it is essential that voltage supplied to an installation be maintained within limits prescribed for each circuit. These limits are listed below: Nominal Voltage Minimum VOLTAGE RANGE Maximum 120 220 277 347 120-277 (UNV) 347-480 (HRV) 108 198 249 312 108 312 132 242 305 382 305 528 Fluorescent-Electronic Subjecting a ballast to excessive voltage for an extended period results in the deterioration of the insulation. This insulation breakdown will cause early ballast failure. Low voltage has no damaging effect on the ballast. However, lamps may not start reliably, and early lamp failure could result. Internal Ballast Protection Class P Classification - Since January 1, 1984, the National Electrical Code requires that “where Fluorescent fixtures are installed indoors, the ballast shall have thermal protection integral within the ballast except for simple reactance ballasts.” This ruling applies to replacement ballasts as well as to those contained within new fixtures. In compliance with the National Electrical Code, UL has established a Class P ballast classification for fluorescent light fixtures. A Class P ballast must employ internal thermal protection limiting its operating temperature. Universal UL-approved Class P ballasts comply with the National Electrical Code requirement and are equipped with an automatic resetting thermal protector, built-in and adjacent to the transformer coils. The resetting thermal protector functions as a thermostat which will open and temporarily deactivate the ballast when it exceeds the permissible temperature. It will reset when the ballast cools to a safe operating temperature. The ballast will continue to cycle until the cause of overheating is eliminated. If the ballast is defective, it must be replaced. If the cause is external, a Class P ballast will resume normal operation after abnormal conditions are eliminated. PAGE 2-4 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Application And Operating Information SAFETY Dimming Ballasts - Ballastar® Dimming Ballasts are controlled by using 10-0vDC. Care should be taken to insure that the line voltage (AC) wires are not connected to the low voltage DC wires. Ballastar® Electronic Dimming Ballasts have protection (safety) circuitry, that will sense the error so as not to harm the installer or the ballast. Dimming ballasts manufactured after May 1999 have the protection circuit. Dimming ballasts manufactured before this date do not have low voltage circuit protection. Fusing - Class P ballasts do not require fusing. Fusing can be used when a single circuit has a large number of fixtures/ballasts. For a comprehensive list of appropriate fuses, contact our Technical Engineering Services (TES) Department at 1-800-BALLAST or check out our TES home page at www.unvlt.com. Grounding - ANSI C82.1 recommends all fixtures and ballasts be grounded. Universal requires all electronic ballasts be grounded. Thermal Protection - All Universal electronic ballasts meet UL 935 Standard for thermal protection. These ballasts are designated Class P. A Class P ballast will disconnect the ballast from input power in the event of internal over-temperature. PERFORMACE Lamp Connections Fluorescent ballasts are designed to generate voltages in excess of 300 volts. It is imperative that proper connection to quality sockets be assured in accordance with wiring diagrams on each page of the catalog and on product labels. Some applications may not require the use of all of the ballast output leads. If any leads are not to be connected, each should be individually capped and insulated to at least 600 volts. Application Versatility Many Universal models are designed to allow for applications with different types or quantities of lamps. Lamp applications not listed on label cannot be warranted. Audible Noise (Sound) Electrical equipment, including most fluorescent lamp ballasts, produces some noise. Care must be taken to select a ballast with the proper sound rating for a particular lighting installation. Secure mounting can reduce the potential for audible noise. Typically, electronic ballasts operate up to 75% quieter than electromagnetic ballasts for fluorescent lamps. EMI/RFI Electronic ballasts operate at high frequency and, therefore, may produce radio frequency interference (RFI) or electromagnetic interference (EMI). Some sensitive electrical equipment such as televisions, radios, or some medical equipment can be adversely affected by this RFI or EMI interference. Currently the electronic frequencies from 450 kilohertz (kHz) to 300 megahertz (MHz) are regulated by the FCC. For electronic ballasts, the limits and regulations are listed in the Code of Federal Regulations, Title 47, Part 18, Subpart C titled RF Lighting Devices. ULT provides ballasts compliant with non-consumer limits for commercial applications, as well as several models in compliance with consumer limits for residential use. See the Data Sheets for the electronic ballast of interest to determine which FCC requirement, consumer or non-consumer the particular product meets. PAGE 2-5 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Remote Mounting Excessive hot or cold temperatures, audible noise requirements, or a desire to operate lamps in more than one fixture with the same ballast (master/slave), may make it desirable to mount the ballast remotely. Care must be taken to allow for ballast heat dissipation and proper grounding. In any application, the wire used to extend leads must be at least as large as the wire supplied on the ballast (18 AWG) with an insulation rating of 1000 VAC at 90°C. Lead lengths in excess of those noted cause loading effects that can dramatically impact ballast performance and void the warranty. Universal T8 Instant Start and Programmed Rapid Start Electronic ballasts can be mounted remotely, from the lamp sockets, up to 18 feet. Universal T8 Rapid Start Electronic ballasts can be mounted remotely, from the lamp sockets, up to 12 feet. Application And Operating Information PERFORMANCE • Lamp Starting Dependability Fluorescent lamps are inherently more difficult to start at low temperatures. All ballasts have limitations as to their ability to start lamps at low ambient temperatures. In this catalog, the low starting point for each lamp/ballast combination appears in the column marked “Minimum Starting Temperature.” Universal four lamp instant start ballasts can operate at a minimum starting temperature down to -18°C (0°F) under the following conditions: 1. Lead lengths to the lamps are those supplied, by Universal, with the ballast or shorter. 2. The distance from the lamp to the ground plane is no greater than 3/4”. 3. The line voltage supplied to the ballast is no less than rated nominal. 4. The ballast or lamps are not remotely mounted. 5. The lamps have been burned in per lamp manufacturer requirements (typically 100 hours). The lamp manufacturer should be contacted for lamp operating characteristics and requirments below 15°C (50°F). • Light Output Optimum light output from fluorescent lamps is achieved when the lamp wall is at 100-110°F. Any substantial excursion (either colder or warmer) will result in a reduction in light output. • Ballast Life A fluorescent lamp ballast, like any other electrical device, generates heat during its normal operation. Ballast temperatures should be kept as low as possible. Maximum dissipation of heat through fixture design and proper ballast installation will help. Although excessive temperature may not cause the ballast to fail immediately, it can shorten ballast life. To assure maximum life, the ballast case temperature should not exceed 75˚C, in a maximum ambient (fixture cavity) of 40˚C. Causes of ballast overheating: • Incorrect line voltage or frequency • Incorrect size, type or number of lamps • Incorrect wiring • Poor heat dissipation due to surrounding insulation • Sealed (Vapor Tight) Fixtures - Unusual heat build-up due to lack of ventilation in fixtures may cause thermal (on/off) cycling of certain ballasts. Consult Universal for specific recommendations. Fluorescent-Electronic RECOMMENDATIONS... • Selection of a proper ballast to match the requirements of the lamp, fixture, voltage and installation. • Mounting of ballast within the fixture with as much surface contact as possible between the ballast and metal portions of the fixture. Secure mounting will aid in proper heat dissipation and can minimize the potential for ballast hum. • The use of heat-conducting dissipators (radiators), if necessary, which increase surface contact between the ballast and fixture. • If necessary, locate the ballast in a remote, cooler area outside the fixture. • Consult Universal for remote mounting recommendations. • Starting Method Legend IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start PAGE 2-6 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Specifications TYPICAL SPECIFICATIONS FOR INSTANT START BALLASTS FOR: Ballasts (1-4 lamp) shall operate as a Parallel Circuit, allowing remaining lamp(s) to maintain full light output if one or more lamps fail. Ballasts shall operate from 60 Hz input source of 120, 277 Volts, and sustained variations of ± 10% (Voltage & Frequency) with no damage to the ballasts. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (Radiated). Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2. Ballasts shall operate lamps with no visible flicker (<3% flicker index). Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. Ballast shall have a Ballast Factor greater than .85 per ANSI C82.11-1993. - Ballast Factor for Low Power (L-A) models shall be greater than .77. Input current Total Harmonic Distortion shall not exceed 20% for the primary lamp applications Ballasts shall have a Power Factor greater than .95 for primary lamp applications. The ballasts do not contain any PCB’s. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of manufacture. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years. Ballast shall be manufactured in an ISO 9001 Certified Facility Ballasts shall provide instant starting sequence consistent with ANSI standard C82.11-1993. Universal model ______________ (or approved equal). PAGE 2-7 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. • RH (Reduced Harmonic) • L (Low Wattage) • RHH and RHH-A (Reduced Harmonic High Output) Specifications Fluorescent-Electronic TYPICAL SPECIFICATIONS FOR INSTANT START BALLASTS FOR: Universal Voltage • HP (High Performance) 1. Ballasts (1-4 lamp) shall operate as a Parallel Circuit, allowing remaining lamp(s) to maintain full light output if one or more lamps fail. 2. Ballasts shall operate from 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ± 10% (Voltage & Frequency) with no damage to the ballasts. 3. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 42 kHz to minimize interference with infared control systems. 4. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. 5. Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (Radiated). 6. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2. 7. Ballasts shall operate lamps with no visible flicker (<3% flicker index). 8. Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage. 9. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. 10. Ballast shall have a Ballast Factor greater than .85 per ANSI C82.11-1993. 11. Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp. 12. Ballasts shall have a Power Factor greater than .98 for primary lamp. 13. The ballasts shall not have any PCB’s. 14. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of manufacture. 15. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years. 16. Ballast shall be manufactured in an ISO 9001 Certified Facility. 17. Ballasts shall provide instant starting sequence consistent with ANSI standard C82.11-1993. 18. Ballast shall be Universal Lighting Technologies Bx32IUNVHP-B (x=1 or 2) or Bx32IUNVHP-A (x=3 or 4) depending upon the quantity of lamps per fixture. 19. Universal model ______________ (or approved equal). PAGE 2-8 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Specifications TYPICAL SPECIFICATIONS FOR INSTANT START BALLASTS FOR: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. • HP (High Performance) • HPL (High Performance Low Power) • HPH (High Performance High Light) Ballasts (1-4 lamp) shall operate as a Parallel Circuit, allowing remaining lamp(s) to maintain full light output if one or more lamps fail (except T12 High Output). Ballasts shall operate from 50/60 Hz input source of 120, 277, and 347 Volts, and sustained variations of ± 10% (Voltage & Frequency) with no damage to the ballasts. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2. Ballasts shall operate lamps with no visible flicker (<3% flicker index). Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. Ballast shall have a Ballast Factor greater than .85 per ANSI C82.11-1993. - Ballast Factor for Low Power (L) models shall be greater than .77. Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp. Ballasts shall have a Power Factor greater than .98 for primary lamp. The ballasts do not contain any PCB’s. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of manufacture. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years. Ballast shall be manufactured in an ISO 9001 Certified Facility Ballasts shall provide instant starting sequence consistent with ANSI standard C82.11-1993. Universal model ______________ (or approved equal). Fluorescent-Electronic PAGE 2-9 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Specifications TYPICAL SPECIFICATIONS FOR RAPID START BALLASTS Ballasts (1-4 lamp) shall operate as a Parallel Circuit, allowing remaining lamps(s) to maintain full light output if one or more lamps fail (except T12 High Output). Ballasts shall operate from 60 Hz input source of 120, 277 Volts, and sustained variations of ± 10% (Voltage & Frequency) with no damage to the ballasts. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (Radiated). Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2. Ballasts shall operate lamps with no visible flicker (<3% flicker index). Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, CSA Certified where applicable. Ballast shall have a Ballast factor greater than .85, per ANSI C82.11-1993. Input current Total Harmonic Distortion shall not exceed 10% for primary lamp applications. Ballast shall be manufactured in an ISO 9001 Certified Facility Ballasts shall have a Power Factor greater than 0.98 primary applications. The ballasts do not contain any PCB’s. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of manufacture. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years. Ballasts shall provide rapid starting sequence consistent with ANSI standard C82.11-1993. Universal model ______________ (or approved equal). Fluorescent-Electronic 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. PAGE 2-10 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Specifications TYPICAL SPECIFICATIONS FOR PROGRAMMED RAPID START BALLASTS: 1. Ballasts shall have a minimum start temperature of 0°F. 2. Ballasts shall operate from a 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ± 10% (Voltage & Frequency) with no damage to the ballasts. 3. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 42 kHz to minimize interference with infrared control systems. 4. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. 5. Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (Radiated). 6. Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991, Location A2. 7. Ballasts shall operate lamps with no visible flicker (<3% flicker index). 8. Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage. 9. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. 10. Ballast shall have a Ballast factor greater than .85, per ANSI C82.11-1993. 11. Input current Total Harmonic Distortion shall not exceed 10%. 12. Ballasts shall have a Power Factor greater than 0.98, for primary application. 13. The ballasts shall not have any PCB’s. 14. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of manufacture. 15. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years. 16. Ballast shall be manufactured in an ISO 9001 Certified Facility. 17. Ballast shall be manufactured in North America. 18. Ballast shall be Universal Lighting Technologies AccuStart HP Product Bx32PUNVHP-A (x=1,2,3. or 4). 19. Universal model ______________ (or approved equal). Fluorescent-Electronic PAGE 2-11 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Specifications TYPICAL SPECIFICATIONS FOR INSTANT START T5 AND T5 HIGH OUTPUT (HO) BALLASTS : Fluorescent-Electronic 1. Ballast shall be Instant Start. 2. Ballast shall incorporate lamp shutdown circuitry for end of lamp life protection. 3. Ballast shall allow for re-lamping without the need to cycle power. 4. Ballasts shall operate from 50/60 Hz input source from 108-305 Volts with no damage to the ballasts. 5. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz. 6. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. 7. Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (Radiated). 8. Ballasts shall provide transient immunity recommended by ANSI C62.41-1991, Location A2. 9. Ballasts shall operate lamps with no visible flicker (<3% flicker index). 10. Ballasts shall tolerate sustained open and short circuit output conditions without damage. 11. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. 12. Ballast shall have a Ballast Factor greater than 0.95 per ANSI C82.11-1993. 13. Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp. 14. Ballasts shall have a Power Factor greater than .98. 15. The ballasts do not contain any PCB’s. 16. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for up to five years from date of manufacture. 17. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years. 18. Ballast shall be manufactured in an ISO 9001 Certified Facility. 19. Universal model ______________ (or approved equal). PAGE 2-12 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Specifications TYPICAL SPECIFICATIONS FOR PROGRAMMED RAPID START T5 AND T5 HIGH OUTPUT (HO) BALLASTS : 1. Ballast shall be Programmed Rapid Start. 2. Ballast shall incorporate lamp shutdown circuitry for end of lamp life protection. 3. Ballast shall allow for re-lamping without the need to cycle power. 4. Ballasts shall operate from 50/60 Hz input source from 108-305 Volts with no damage to the ballasts. 5. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz. 6. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. 7. Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (Radiated). 8. Ballasts shall provide transient immunity recommended by ANSI C62.41-1991, Location A2. 9. Ballasts shall operate lamps with no visible flicker (<3% flicker index). 10. Ballasts shall tolerate sustained open and short circuit output conditions without damage. 11. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified where applicable. 12. Ballast shall have a Ballast Factor greater than 0.95 per ANSI C82.11-1993. 13. Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp. 14. Ballasts shall have a Power Factor greater than .98. 15. The ballasts do not contain any PCB’s. 16. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for up to five years from date of manufacture. 17. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years. 18. Ballast shall be manufactured in an ISO 9001 Certified Facility. 19. Universal model ______________ (or approved equal). Fluorescent-Electronic PAGE 2-13 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) F17T8 • Low Profile Designs Featured TRIAD® ELECTRONIC BALLASTS FOR (1) & (2) F17T8 LAMP • Instant & Programmed Rapid Starting Options Fluorescent-Electronic • 1-2 Lamp Applications Lamp Certification Line Input Power Starting Line Catalog Current Power Factor NOM Qty. Method Volts Number (Amps) (Watts) (PF) F17T8 - One Lamp Application 120 B132I120RH-A • • • 0.17 19 > .90 277 B132I277RH-A • • 0.07 20 > .90 347 B132I347RH • 0.05 18 > .95 120 0.14 B132IUNVHP-B • • 17 >.95 277 0.07 1 347 B132I347HP • 0.05 18 > .95 IS 120 B232I120RES-A* • • • 0.35 21 > .50 120 B232I120RES-G* • • • 0.34 22 > .50 120 0.17 > .98 B232IUNV-C • • 20 277 0.08 > .95 120 0.12 > .98 B132IUNVEL-A • • 14 277 0.06 > .90 120 0.13 > .98 B132IUNVHE-A • • 16 277 0.07 > .90 120 0.14 16 ES1608A • • > .97 277 0.07 17 120 0.15 > .99 B132PUNVHP-A • • • 17 1 PRS 277 0.07 > .96 347 ES1510A • 0.05 18 > .97 F17T8 - Two Lamp Applications 120 B232I120L-A • • 0.27 30 > .90 277 B232I277L-A • • 0.12 30 > .90 347 B232I347L-A • 0.09 29 > .98 120 B232I120RES-G* • • • 0.49 33 > .50 120 B232I120RES-A* • • • 0.49 32 > .50 120 B232I120RH-A • • • 0.31 34 > .90 277 B232I277RH-A • • • 0.13 34 > .90 347 B232I347RH-A • 0.09 32 > .95 2 PAR-IS 347 B232I347HPL • 0.09 29 > .98 120 0.26 > .99 B232IUNVHP-B • • • 32 277 0.12 > .98 347 B232I347HP-A • 0.09 32 > .95 120 0.27 > .99 B232IUNV-C • • 31 277 0.12 > .98 120 0.21 25 B232IUNVEL-A • • > .95 277 0.10 26 120 B232I120EL • • 0.22 26 > .98 277 B232I277EL • • 0.11 27 > .98 120 0.24 B232IUNVHE-A • • 30 > .95 277 0.12 120 0.33 41 B232IUNVHEH-A • • > .95 277 0.15 40 120 B232I120HE • • 0.25 30 > .98 277 B232I277HE • • 0.12 30 > .95 120 0.24 29 2 SER-IS ES1608A • • > .97 277 0.11 30 120 0.22 26 B232PUNVEL-A • > .90 277 0.10 26 120 0.24 29 B232PUNVHE-A • > .90 277 0.11 28 2 SER-PRS 120 0.29 35 ES4800A • • > .97 277 0.13 36 120 0.28 > .99 B232PUNVHP-A • • • 34 277 0.13 > .95 347 ES1329A • • 0.11 36 > .97 * For Residential Use Only Ballast Ballast Min. F/C Factor Efficacy THD Start Wiring (BF) Factor (BEF) % Temp Diag. Dim. 0.93 0.93 0.92 < 32 < 32 < 20 < 10 < 15 < 15 < 150 < 150 0/-18 0/-18 0/-18 1 1 1 0/-18 0/-18 0/-18 0/-18 1 1 3a 3a 1.04 4.89 4.65 5.11 5.24 5.11 5.14 4.91 5.20 < 10 0/-18 21a 0.78 5.57 < 15 0/-18 1 -A 0.90 5.63 < 10 0/-18 1 -A 0.87 5.44 5.12 5.35 4.83 < 10 0/-18 39a ESA < 10 < 15 < 10 0/-18 0/-18 2 40 0.89 0.92 1.08 1.08 0.91 0.87 0.85 0.86 0.80 0.94 0.94 0.95 0.95 0.92 0.79 -A -A ST -B ST -A -G -C -A ESA < 32 < 32 < 20 < 140 < 140 < 32 < 32 < 20 < 10 < 10 < 10 < 10 < 10 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 3 3 3 3 3 3 3 3 3 0/-18 0/-18 3 3 0.91 0.80 0.79 0.80 2.83 2.87 2.76 2.85 2.94 2.79 2.79 2.88 2.72 2.84 2.88 2.94 3.20 3.08 3.04 2.96 0/-18 21 -C < 10 0/-18 3 -A <10 <15 0/-18 0/-18 3 3 ST ST 0.90 3.00 < 10 0/-18 3 -A 1.18 0.91 0.91 0.87 0.72 0.84 0.95 2.88 2.95 3.03 3.03 3.00 2.90 2.77 2.77 2.90 3.00 2.71 2.64 2.79 2.42 < 10 0/-18 3 -A <10 <10 0/-18 0/-18 3 3 ST ST < 10 0/-18 39 ESA < 10 0/-18 30 -A < 10 0/-18 30 -A < 10 0/-18 37 ESA < 10 < 15 <10 0/-18 0/-18 30 37 -A 0.91 0.92 0.95 0.87 -A -A -A -G -A -A -A -A ST -B -A ESA See page 2-18 for Dimensions and Wiring Diagrams IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start SER-PRS = Series Programmed Rapid Start PAGE 2-14 PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start SER-IS = Series Instant Start FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® ELECTRONIC BALLASTS FOR (3) & (4) F17T8 LAMPS F17T8 • Low Profile Designs Featured • Instant & Programmed Rapid Starting Options • 3-4 Lamp Applications * For Residential Use Only Line Input Power Ballast Ballast Min. F/C Current Power Factor Factor Efficacy THD Start Wiring (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. 0.40 0.17 0.12 0.47 0.20 0.14 0.12 0.38 0.18 0.14 0.35 0.15 0.32 0.15 0.39 0.17 0.36 0.17 0.49 0.22 0.72 0.41 0.18 0.39 0.18 0.41 0.19 44 44 43 52 52 47 43 45 48 42 41 38 40 46 43 44 60 58 51 49 48 46 47 49 48 0.48 0.21 0.17 0.84 0.54 0.23 0.19 0.17 0.49 0.22 0.19 0.49 0.22 0.44 0.20 0.42 0.22 0.49 0.22 0.47 0.22 0.28 0.48 0.23 0.53 0.24 55 54 56 61 63 61 64 56 59 58 62 59 58 53 52 51 51 59 58 56 58 77 57 58 63 62 >.90 >.95 >.99 > .90 > .90 > .95 > .99 > .99 > .90 > .98 > .99 > .95 >.98 >.98 > .99 > .97 >.98 >.95 0.86 0.88 0.80 0.99 0.99 0.90 0.80 0.92 0.92 0.82 0.79 0.80 > .95 > .50 > .98 > .95 1.19 1.00 0.99 0.87 > .97 > .99 > .90 > .95 > .95 > .97 > .50 > .95 > .95 > .95 > .97 > .98 > .90 > .98 > .98 > .95 > .98 > .95 > .98 > .98 > .98 > .95 > .98 > .98 > .99 > .97 > .99 > .90 0.92 0.89 0.91 0.93 0.79 0.80 0.82 0.92 0.92 0.92 0.92 0.82 0.90 0.92 0.91 0.79 0.81 0.80 0.90 0.91 0.91 1.20 0.87 0.91 1.95 2.00 1.85 1.90 1.90 1.91 1.85 2.04 1.92 1.95 2.00 2.08 2.00 <30 <25 <20 < 32 < 32 < 20 < 10 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 6 6 6 6 6 6 6 -A -A ST -A -A ST ST < 10 < 10 0/-18 0/-18 6 -A 6 ST 2.00 < 10 0/-18 6 -A 2.07 2.07 1.98 2.05 1.96 1.98 2.02 1.89 1.85 1.90 1.94 <10 <10 0/-18 0/-18 6 6 ST ST < 10 0/-18 < 135 0/-18 < 10 0/-18 < 12 6 7a -A -A 24 -D 1.44 1.48 1.46 1.51 1.46 1.51 1.44 1.46 1.53 1.55 1.48 1.51 1.56 1.49 1.52 1.59 1.57 1.53 1.55 1.63 1.57 1.56 1.53 1.50 1.44 1.47 < 10 0/-18 6 -A <10 <15 0/-18 0/-18 6 6 ST ST < 10 0/-18 38a ESB < 10 0/-18 23 -A < 20 < 20 < 20 < 130 < 20 < 20 < 20 < 10 < 10 < 10 < 10 < 12 0/-18 0/-18 0-/18 0/-18 0/-18 0/-18 0/-18 0/-18 7a 7a 7 7a 7a 7a 7a 7 -A -A ST -A -A -A ST ST 0/-18 0/-18 7a 7a ST 0/-18 25 -D < 10 0/-18 7a -A < 10 < 15 0/-18 0/-18 7a 7a ST ST < 10 0/-18 7a -A < 10 < 10 < 10 0/-18 0/-18 0/-18 7a 7a 7a ST ST ST < 10 0/-18 38 ESB < 10 0/-18 8 -A -A See page 2-18 for Dimensions and Wiring Diagrams PAGE 2-15 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Lamp Certification Starting Line Catalog NOM Qty. Method Volts Number F17T8 - Three Lamp Applications 120 B332I120L-A • • 277 B332I277L-A • • 347 B332I347L • 120 B332I120RH-A • • • 277 B332I277RH-A • • • 347 B332I347RH • 347 B332I347HPL • 120 B332IUNVHP-A • • • 3 PAR-IS 277 347 B332I347HP • 120 B332IUNVEL-A • • 277 120 B332I120EL • • 277 B332I277EL • • 120 B332IUNVHE-A • • 277 120 B332I120HE • • 277 B332I277HE • • 120 B332IUNVHEH-A • • 277 120 B432I120RES-A* • • • 120 B432IUNV-D • • 277 120 ES1720B • • 277 120 3 SER-PRS B332PUNVHP-A • • • 277 F17T8 - Four Lamp Applications 120 B432I120L-A • • 277 B432I277L-A • • 347 B432I347L • 120 B432I120RES-A* • • • 120 B432I120RH-A • • • 277 B432I277RH-A • • • 347 B432I347RH • 347 B432I347HPL • 4 PAR-IS 120 B432IUNVHP-A • • • 277 347 B432I347HP • 120 B432IUNV-D • • 277 120 B432IUNVEL-A • • 277 120 B432I120EL • • 277 B432I277EL • • 120 B432IUNVHE-A • • 277 120 B432I120HE • • 277 B432I277HE • • 277 B432I277HEH • • 120 ES1720B • • 277 120 4 SER-PRS B432PUNVHP-A • • • 277 F25T8 • Standard & Low Profile Designs Featured TRIAD® ELECTRONIC BALLASTS • Instant & Programmed Rapid Starting Options FOR (1) & (2) F25T8 LAMP Fluorescent-Electronic • 1-2 Lamp Applications Lamp Certification Line Input Power Ballast Ballast Min. F/C Starting Line Catalog Current Power Factor Factor Efficacy THD Start Wiring NOM Qty. Method Volts Number (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. F25T8 - One Lamp Applications 120 B132I120RH-A • • • 0.22 26 > .97 0.92 3.54 < 25 0/-18 1 -A 277 B132I277RH-A • • 0.10 27 > .97 0.92 3.41 < 25 0/-18 1 -A 347 B132I347RH • 0.07 25 > .95 0.90 3.60 < 20 0/-18 1 ST 120 0.21 B132IUNVHP-B • • 24 >.95 0.88 3.67 < 10 0/-18 1 -B 277 0.09 1 IS 347 B132I347HP • 0.07 25 > .95 0.90 3.60 < 10 0/-18 1 ST 120 0.18 > .98 B132IUNVEL-A • • 19 0.78 4.11 <10 0/-18 1 -A 277 0.09 > .90 120 0.18 > .98 B132IUNVHE-A • • 22 0.89 4.05 <10 0/-18 1 -A 277 0.10 > .95 120 0.20 > .99 1 PRS B132PUNVHP-A • • • 24 0.91 3.79 < 10 0/-18 2 -A 277 0.09 > .98 347 ES1510A • • 0.07 24 > .97 0.87 2.81 < 10 0/-18 40 ESA 347 B232I347HPL • 0.08 26 > .98 0.88 3.38 < 10 0/-18 3 ST 120 B232I120RES-A* • • • 0.43 28 > .50 1.08 3.86 < 150 0/-18 3a -A 120 B232I120RES-G* • • • 0.43 28 > .50 1.08 3.86 < 150 0/-18 3a -G 1 IS 120 0.24 B232IUNV-C • • 28 > .98 1.02 3.64 < 10 0/-18 21 -C 277 0.11 120 0.19 23 3.78 ES1608A • • > .97 0.87 < 10 0/-18 39a ESA 277 0.09 24 3.63 120 0.22 25 3.92 1 PRS ES4800A • • > .97 1.02 < 10 0/-18 37 ESA 277 0.09 26 4.08 F25T8 - Two Lamp Applications 120 B232I120L-A • • 0.37 43 > .95 0.78 1.81 < 20 0/-18 3 -A 277 B232I277L-A • • 0.16 43 > .95 0.80 1.86 < 20 0/-18 3 -A 347 B232I347L-A • 0.12 39 > .98 0.79 2.03 < 20 0/-18 3 -A 120 B232I120RES-A* • • • 0.64 46 > .50 0.92 2.00 < 130 0/-18 3 -A 120 B232I120RES-G* • • • 0.64 46 > .50 0.92 2.00 < 140 0/-18 3 -G 120 B232I120RH-A • • • 0.41 48 > .95 0.93 1.94 < 20 0/-18 3 -A 277 B232I277RH-A • • • 0.18 48 > .95 0.93 1.94 < 20 0/-18 3 -A 347 B232I347RH-A • 0.13 46 > .95 0.89 1.93 < 20 0/-18 3 -A 347 B232I347HPL • 0.12 41 > .98 0.75 1.83 < 10 0/-18 3 ST 120 0.37 45 > .99 2.00 B232IUNVHP-B • • • 0.90 < 10 0/-18 3 -B 277 0.16 44 > .98 2.05 2 PAR-IS 347 B232I347HP-A • 0.13 46 > .95 0.89 1.93 < 10 0/-18 3 -A 120 0.37 45 2.00 B232IUNV-C • • > .98 0.90 < 10 0/-18 21 -C 277 0.16 44 2.05 120 0.30 36 0.79 2.19 B232IUNVEL-A • • > .95 < 10 0/-18 3 -A 277 0.14 37 0.80 2.18 120 B232I120EL • • 0.33 39 > .98 0.78 2.00 < 10 0/-18 3 ST 277 B232I277EL • • 0.15 37 > .98 0.79 2.14 < 10 0/-18 3 ST 120 0.36 B232IUNVHE-A • • 44 > .95 0.88 2.00 < 10 0/-18 3 -A 277 0.16 120 0.51 61 1.93 B232IUNVHEH-A • • > .95 1.18 < 10 0/-18 3 -A 277 0.22 60 1.97 120 B232I120HE • • 0.35 42 > .98 0.90 2.14 < 10 0/-18 3 ST 277 B232I277HE • • 0.16 43 > .98 0.90 2.09 < 10 0/-18 3 ST 120 0.36 2 SER-IS ES1608A • • 43 > .97 0.87 2.02 < 10 0/-18 39 ESA 277 0.16 120 0.31 37 1.92 B232PUNVEL-A • > .90 0.71 <10 0/-18 30 -A 277 0.14 36 2.00 120 0.35 42 1.98 B232PUNVHE-A • > .90 0.83 <10 0/-18 30 -A 277 0.15 41 2.02 2 SER-PRS 120 0.40 47 > .99 2.00 B232PUNVHP-A • • • 0.94 <10 0/-18 30 -A 277 0.17 46 > .97 2.04 347 ES1329A • • 0.14 49 > .97 0.87 1.78 <10 0/-18 37 ESA 120 0.40 47 2.00 ES4800A • • > .97 0.94 < 10 0/-18 37 ESA 277 0.17 46 2.04 * For Residential Use Only See page 2-18 for Dimensions and Wiring Diagrams PAGE 2-16 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® ELECTRONIC BALLASTS FOR (3) & (4) F25T8 LAMPS F25T8 • Low Profile Designs Featured • Instant & Programmed Rapid Starting Options • 3-4 Lamp Applications * For Residential Use Only IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Line Input Power Ballast Ballast Min. F/C Current Power Factor Factor Efficacy THD Start Wiring (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. 0.52 0.22 0.17 0.60 0.26 0.20 0.17 0.55 0.25 0.20 0.49 0.22 0.47 0.20 0.56 0.24 0.52 0.24 0.69 0.30 0.58 0.26 0.96 0.62 0.26 0.52 0.24 61 62 60 70 70 68 60 66 65 68 59 58 56 56 67 66 61 64 83 81 70 71 74 72 63 64 > .95 < .98 > .99 > .95 > .95 > .95 > .99 > .99 > .98 > .99 > .99 > .97 > .98 > .98 > .99 > .98 > .98 > .98 > .95 > .99 > .95 > .50 0.68 0.30 0.24 1.13 0.74 0.32 0.26 0.24 0.74 0.32 0.26 0.73 0.31 0.65 0.28 0.60 0.28 0.72 0.31 0.71 0.32 0.41 0.69 0.31 0.77 0.33 78 76 83 85 87 84 90 83 87 85 90 87 85 78 76 77 77 87 85 85 86 114 83 92 89 > .95 > .95 > .98 > .50 > .95 > .95 > .95 > .98 > .99 > .95 > .98 > .98 > .98 > .97 > .98 > .98 > .98 > .99 > .98 > .98 > .98 > .99 > .97 > .99 > .95 1.34 1.34 1.26 1.33 1.33 1.32 1.26 1.36 1.38 1.34 1.36 1.38 1.39 1.41 1.34 1.36 1.44 1.41 1.40 1.43 1.31 1.38 1.32 1.36 1.38 1.36 0.78 0.78 0.78 0.90 0.91 0.91 0.90 0.78 0.89 0.90 0.90 0.78 0.80 0.79 0.89 0.89 0.89 1.19 0.87 0.89 < 25 < 20 < 20 < 20 < 25 < 20 < 10 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 6 6 6 6 6 6 6 -A -A ST -A -A ST ST <10 0/-18 6 -A < 10 0/-18 6 ST < 10 0/-18 6 -A < 10 < 10 0/-18 0/-18 6 6 ST ST < 10 0/-18 6 -A < 10 < 10 0/-18 0/-18 6 6 ST ST < 10 0/-18 6 -A < 10 0/-18 23 -A < 130 0/-18 7a -A < 10 0/-18 24 -D < 10 0/-18 38a ESB 1.00 1.03 0.94 1.06 1.05 1.08 1.00 0.94 1.02 1.05 1.00 1.03 1.06 1.00 1.03 1.04 1.03 1.02 1.05 1.05 1.03 1.04 < 20 < 20 < 20 < 130 < 20 < 20 < 20 < 10 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 7a 7a 7 7a 7a 7a 7a 7 -A -A ST -A -A -A ST ST < 10 < 10 0/-18 0/-18 7a 7a -A ST < 10 0/-18 25 -D < 10 0/-18 7a -A < 10 < 10 0/-18 0/-18 7a 7a ST ST < 10 0/-18 7a -A < 10 < 10 < 10 0/-18 0/-18 0/-18 7a 7a 7a ST ST ST 1.05 < 10 0/-18 38 ESB 0.97 1.00 < 10 0/-18 8 -A See page 2-18 for Dimensions and Wiring Diagrams STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start SER-PRS = Series Programmed Rapid Start PAGE 2-17 0.82 0.83 0.76 0.93 0.93 0.90 0.76 0.92 0.91 0.80 0.78 0.79 0.90 0.88 0.90 1.16 0.92 0.98 0.98 0.87 PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Lamp Certification Starting Line Catalog NOM Qty. Method Volts Number F25T8 - Three Lamp Applications 120 B332I120L-A • • 277 B332I277L-A • • 347 B332I347L • 120 B332I120RH-A • • • 277 B332I277RH-A • • • 347 B332I347RH • 347 B332I347HPL • 3 PAR-IS 120 B332IUNVHP-A • • • 277 347 B332I347HP • 120 B332IUNVEL-A • • 277 120 B332I120EL • • 277 B332I277EL • • 120 B332IUNVHE-A • • 277 120 B332I120HE • • 277 B332I277HE • • 120 B332IUNVHEH-A • • 277 120 3 SER-PRS B332PUNVHP-A • • • 277 120 B432I120RES-A* • • • 3 PAR-IS 120 B432IUNV-D • • 277 120 ES1720B • • 277 F25T8 - Four Lamp Applications 120 B432I120L-A • • 277 B432I277L-A • • 347 B432I347L • 120 B432I120RES-A* • • • 120 B432I120RH-A • • • 277 B432I277RH-A • • • 347 B432I347RH • 347 B432I347HPL • 4 PAR-IS 120 B432IUNVHP-A • • • 277 347 B432I347HP • 120 B432IUNV-D • • 277 120 B432IUNVEL-A • • 277 120 B432I120EL • • 277 B432I277EL • • 120 B432IUNVHE-A • • 277 120 B432I120HE • • 277 B432I277HE • • 277 B432I277HEH • • 120 ES1720B • • 277 120 4 SER-PRS B432PUNVHP-A • • • 277 F17T8 & F25T8 TRIAD® ELECTRONIC BALLASTS FOR F17T8 & F25T8 LAMPS Overall Dimensions Draw # L Fluorescent-Electronic ST -A -B -C -D -G ESA ESB 9.50” 9.50” 9.50” 14.25” 16.88” 9.50” 9.50” 9.50” Mounting Dimensions H M X W 2.40” 1.70” 1.50” 1.18” 1.18” 1.18” 1.56” 2.38” 1.55” 1.18” 1.00” 1.00” 1.00” 1.00” 1.00” 1.00” ST 8.89” 8.89” 8.89” 13.75” 16.20” 8.89” 8.88” 8.88” WIRING DIAGRAMS 1.69” 1.69” 0.88” ------0.78” --- DIAGRAM 2 DIAGRAM 1 DIAGRAM 3 -A, -B, -G, ESA, ESB Line Black White -C, -D BALLAST DIAGRAM 3a Blue Blue Blue Red LAMP LAMP LAMP DIAGRAM 6 DIAGRAM 7 DIAGRAM 37a For three lamp operation, cap any blue lead, insulate to 600V DIAGRAM 8 DIAGRAM 7a DIAGRAM 38 DIAGRAM 38a DIAGRAM 21 DIAGRAM 21a DIAGRAM 39 DIAGRAM 39a DIAGRAM 30 DIAGRAM 23 DIAGRAM 40 DIAGRAM 24 PAGE 2-18 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® ELECTRONIC BALLASTS FOR (1) F32T8 LAMP F32T8 • Low Profile Designs Featured • Instant & Programmed Rapid Starting Options • 1 Lamp Applications IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAGE 2-19 PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Lamp Certification Line Input Power Ballast Ballast Min. F/C Starting Line Catalog Current Power Factor Factor Efficacy THD Start Wiring NOM Qty. Method Volts Number (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. F32T8 - One Lamp Applications 120 B132I120RH-A • • • 0.26 31 > .98 0.88 2.84 < 20 0/-18 1 -A 277 B132I277RH-A • • 0.11 31 > .97 0.88 2.84 < 20 0/-18 1 -A 347 B132I347RH • 0.09 31 > .98 0.88 2.84 < 20 0/-18 1 ST 120 0.25 30 2.93 B132IUNVHP-B • • > .95 0.88 < 10 0/-18 1 -B 277 0.12 29 3.03 347 B132I347HP • 0.09 31 > .98 0.88 2.84 < 10 0/-18 1 ST 120 0.22 > .98 B132IUNVEL-A • • 25 0.77 3.08 < 10 0/-18 1 -A 277 0.11 > .95 120 0.24 > .98 B132IUNVHE-A • • 28 0.87 3.11 < 10 0/-18 1 -A 277 0.12 > .95 120 B232I120L-A • • 0.29 33 > .90 0.96 2.91 < 32 0/-18 3a -A 277 B232I277L-A • • 0.13 33 > .90 1.00 3.03 < 32 0/-18 3a -A 347 B232I347L-A • 0.10 33 > .98 0.96 2.91 < 20 0/-18 3a -A 120 B232I120RES-A* • • • 0.53 35 > .50 1.06 3.03 < 135 0/-18 3a -A 120 B232I120RES-G* • • • 0.53 36 > .50 1.06 2.94 < 150 0/-18 3a -G 120 B232I120RH-A • • • 0.31 38 > .90 1.09 2.87 < 25 0/-18 3a -A 277 B232I277RH-A • • • 0.14 38 > .90 1.09 2.87 < 25 0/-18 3a -A 347 B232I347RH-A • 0.11 36 > .95 1.05 2.92 < 20 0/-18 3a -A 347 B232I347HPL • 0.09 32 > .98 0.91 2.84 < 10 0/-18 3a ST 120 0.29 > .99 1 IS B232IUNVHP-B • • • 35 1.05 3.00 < 10 0/-18 3a -B 277 0.13 > .98 347 B232I347HP-A • 0.11 36 > .95 1.05 2.92 < 10 0/-18 3a -A 120 0.29 B232IUNV-C • • 35 > .98 1.02 3.19 < 10 0/-18 22 -C 277 0.13 120 0.24 B232IUNVEL-A • • 30 > .95 0.95 3.17 < 10 0/-18 3a -A 277 0.11 120 B232I120EL • • 0.24 29 > .98 0.90 3.10 < 10 0/-18 3a ST 277 B232I277EL • • 0.11 30 > .98 0.92 3.07 < 10 0/-18 3a ST 120 0.28 B232IUNVHE-A • • 33 > .95 1.05 3.18 < 10 0/-18 3a -A 277 0.13 120 0.39 47 2.94 B232IUNVHEH-A1 • • > .95 1.38 < 10 0/-18 3a -A 277 0.18 46 3.00 120 B232I120HE • • 0.27 33 > .98 1.00 3.03 < 10 0/-18 3a ST 277 B232I277HE • • 0.13 34 > .98 1.03 3.03 < 10 0/-18 3a ST 120 0.25 30 2.90 ES1608A • • > .97 0.87 < 10 0/-18 39a ESA 277 0.11 31 2.81 120 0.24 B232PUNVHE-A • 29 > .90 0.88 3.03 < 10 0/-18 30 -A 277 0.11 120 0.20 25 2.89 B232PUNVEL-A • > .90 0.88 < 10 0/-18 30 -A 277 0.09 23 3.09 120 0.26 31 > .99 2.84 B132PUNVHP-A • • • 0.88 < 10 0/-18 2 -A 1 PRS 277 0.11 30 > .98 2.93 347 ES1510A • 0.09 31 > .97 0.87 2.81 < 10 0/-18 40 ESA 120 0.26 31 See page 2-23 3.23 Wiring 37 Diagrams ES4800A • • > .97 1.00 for Dimensions < 10 and 0/-18 ESA 277 0.12 32 3.13 120 0.27 > .99 < 10 B232PUNVHP-A • • • 32 1.00 3.13 0/-18 30 -A 277 0.12 > .95 < 15 * For Residential Use Only 1 Consult Lamp Manufacturers for applications with Ballast Factor > 1.20 F32T8 TRIAD® ELECTRONIC BALLASTS • Low Profile Designs Featured FOR (2) F32T8 LAMPS • Instant & Programmed Rapid Starting Options Fluorescent-Electronic • 2 Lamp Applications Lamp Certification Starting Line Catalog NOM Qty. Method Volts Number F32T8 - Two Lamp Applications 120 B232I120L-A • • 277 B232I277L-A • • 347 B232I347L-A • 120 B232I120RES-A* • • • 120 B232I120RES-G* • • • 120 B232I120RH-A • • • 277 B232I277RH-A • • • 347 B232I347RH-A • 120 B232I120RHH-A • • 277 B232I277RHH-A • • 347 B232I347HPL • 2 PAR-IS 120 B232IUNVHP-B • • • 277 347 B232I347HP-A • 120 B232IUNV-C • • 277 120 B232IUNVEL-A • • 277 120 B232I120EL • • 277 B232I277EL • • 120 B232IUNVHE-A • • 277 120 B232IUNVHEH-A • • 277 120 B232I120HE • • 277 B232I277HE • • 347 B332IHRVHB-E • • 480 2 SER-IS 120 ES1608A • • 277 120 B332I120L-A • • 277 B332I277L-A • • 347 B332I347L • 120 B332I120RH-A • • • 277 B332I277RH-A • • • 347 B332I347RH • 347 B332I347HPL • 120 B332IUNVHP-A • • • 277 2 PAR-IS 347 B332I347HP • 120 B332IUNVEL-A • • 277 120 B332I120EL • • 277 B332I277EL • • 120 B332IUNVHE-A • • 277 120 B332I120HE • • 277 B332I277HE • • 120 1 B332IUNVHEH-A • • 277 120 B232PUNVEL-A • 277 2 SER-PRS 120 B232PUNVHE-A • 277 120 B232PUNVHP-A • • • 277 * For Residential Use Only 1 Consult lamp manufacturers Line Input Power Ballast Ballast Min. F/C Current Power Factor Factor Efficacy THD Start Wiring (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. 0.44 0.19 0.15 0.80 0.80 0.49 0.22 0.17 0.66 0.29 0.14 0.47 0.19 0.17 0.48 0.20 0.40 0.17 0.40 0.18 0.45 0.20 0.62 0.26 0.45 0.20 0.22 0.17 0.48 0.21 0.51 0.21 0.16 0.59 0.26 0.19 0.16 0.53 0.24 0.19 0.48 0.21 0.45 0.20 0.53 0.23 0.50 0.23 0.69 0.30 0.40 0.17 0.47 0.20 0.52 0.22 51 51 51 56 56 58 58 58 77 77 50 56 55 58 58 56 48 47 47 55 54 74 73 54 53 76 57 56 58 61 56 69 69 65 56 63 66 57 56 53 55 64 63 60 61 83 81 47 46 56 55 62 60 PAGE 2-20 > .95 > .95 > .98 > .50 > .50 > .98 > .98 > .99 > .98 > .98 > .99 0.78 0.78 0.78 0.88 0.88 0.88 0.88 0.88 1.18 1.18 0.78 0.88 > .99 > .99 0.88 > .98 0.88 > .95 0.77 1.53 1.53 1.53 1.57 1.57 1.52 1.52 1.52 1.53 1.53 1.56 1.57 1.60 1.52 1.52 1.57 < 20 < 20 < 20 < 120 < 130 < 20 < 20 < 20 < 20 < 20 < 10 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 3 3 3 3 3 3 3 3 3 3 3 -A -A -A -A -G -A -A -A -A -A ST < 10 < 10 0/-18 0/-18 3 3 -A < 10 0/-18 21 -B -C 1.60 < 10 0/-18 3 -A 0.77 0.77 0.87 1.18 0.87 0.87 1.64 1.64 1.58 1.61 1.59 1.62 1.61 1.64 < 10 < 10 0/-18 0/-18 3 3 ST ST < 10 0/-18 3 -A < 10 0/-18 3 -A < 10 < 10 0/-18 0/-18 3 3 ST ST 1.22 1.61 < 10 0/-18 46 -E > .97 0.87 > .95 0.92 > .98 0.92 > .99 0.87 > .95 1.03 > .95 1.04 > .95 0.99 > .99 0.87 > .99 0.99 > .95 > .99 0.99 > .99 0.89 > .97 > .98 0.86 > .98 0.87 > .99 0.99 > .98 > .98 0.96 > .98 1.01 > .95 1.27 > .90 0.71 > .90 > .90 0.88 > .90 > .99 0.88 > .98 1.53 1.55 1.59 1.51 1.55 1.49 1.51 1.52 1.55 1.57 1.50 1.56 1.59 1.62 1.58 1.55 1.57 1.60 1.66 1.53 1.57 1.51 1.54 1.57 1.60 1.42 1.47 < 10 0/-18 39 ESA < 25 < 20 < 20 < 25 < 25 < 20 < 10 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 6 6 6 6 6 6 6 -A -A ST -A -A ST ST < 10 < 10 0/-18 6 -A 0/-18 6 ST < 10 0/-18 6 -A < 10 < 10 0/-18 0/-18 6 6 ST ST < 10 0/-18 6 -A < 10 < 10 0/-18 0/-18 6 6 ST ST < 10 0/-18 6 -A < 10 0/-18 30 -A < 10 0/-18 30 -A < 10 0/-18 30 -A > .98 > .98 > .95 > .95 > .98 > .98 > .97 > .90 See page 2-23 for Dimensions and Wiring Diagrams FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® ELECTRONIC BALLASTS FOR (3) F32T8 LAMPS F32T8 • Low Profile Designs Featured • Instant & Programmed Rapid Starting Options • 3 Lamp Applications Input Power (Watts) 58 60 59 64 63 76 76 75 86 86 85 113 113 75 85 83 88 74 73 70 70 83 81 80 79 111 108 110 109 92 90 83 83 83 92 92 92 95 83 92 89 92 92 91 80 78 79 76 89 87 88 89 119 80 82 92 90 PAGE 2-21 Power Ballast Ballast Min. F/C Factor Factor Efficacy THD Start Wiring (PF) (BF) Factor (BEF) % Temp Diag. Dim. 1.50 > .97 0.87 < 10 0/-18 37 ESA 1.45 > .97 0.87 1.47 <10 0/-18 37 ESA > .99 1.55 0.99 < 10 0/-18 23 -A > .90 1.57 > .98 > .98 > .99 > .98 > .98 > .98 > .98 > .98 > .99 > .99 > .98 > .99 > .99 > .98 > .98 > .99 > .99 > .98 > .98 > .99 > .98 > .98 > .95 > .99 > .95 > .97 > .97 > .98 > .50 > .95 > .95 > .95 > .98 > .99 > .95 > .98 > .98 > .99 > .98 > .98 > .98 > .99 > .98 > .98 > .98 > .99 > .97 > .99 > .95 0.78 0.78 0.79 0.88 0.88 0.88 1.18 1.18 0.79 0.88 0.88 0.77 0.77 0.77 0.87 0.87 0.87 1.18 1.18 0.88 0.83 0.84 0.87 0.96 0.94 0.99 0.99 0.87 0.94 0.99 0.96 0.86 0.84 0.87 0.94 0.96 0.96 1.28 0.87 0.93 1.03 1.03 1.05 1.02 1.02 1.04 1.04 1.04 1.05 1.02 1.05 1.00 1.05 1.07 1.10 1.10 1.04 1.05 1.09 1.10 1.06 1.09 1.07 1.08 0.96 0.98 1.00 1.01 1.05 1.04 1.02 1.08 1.04 1.05 1.02 1.06 1.08 1.02 1.05 1.08 1.10 1.06 1.14 1.06 1.08 1.09 1.08 1.08 1.09 1.06 1.01 1.03 < 20 < 20 < 20 < 20 < 20 < 20 < 20 < 20 < 10 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 6 6 6 6 6 6 6 6 6 -A -A ST -A -A ST ST ST ST < 10 < 10 0/-18 0/-18 6 6 -A ST < 10 0/-18 6 -A < 10 < 10 0/-18 0/-18 6 6 ST ST < 10 0/-18 6 -A < 10 < 10 0/-18 0/-18 6 6 ST ST < 10 0/-18 6 -A < 10 0/-18 46 -E < 10 < 20 < 20 < 20 < 130 < 20 < 20 < 20 < 10 < 10 < 10 < 10 0/-18 23 -A 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 7a 7a 7 7a 7a 7a 7a 7 -A -A ST -A -A -A ST ST 0/-18 0/-18 7a 7a -A 0/-18 24 -D < 10 0/-18 7a -A < 10 < 10 0/-18 0/-18 7 7 ST ST < 10 0/-18 7a -A < 10 < 10 < 10 0/-18 0/-18 0/-18 7 7 7 ST ST ST < 10 0/-18 < 10 0/-18 S 38a ESB 8 -A See page 2-23 for Dimensions and Wiring Diagrams FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Lamp Certification Line Starting Line Catalog Current NOM Qty. Method Volts Number (Amps) 120 0.49 ES4800A • • 277 0.22 347 ES1329A • • 0.17 120 0.54 B332PUNVHP-A • • • 277 0.24 F32T8 - Three Lamp Applications 120 B332I120L-A • • 0.65 277 B332I277L-A • • 0.28 347 B332I347L • 0.21 120 B332I120RH-A • • • 0.75 277 B332I277RH-A • • • 0.33 347 B332I347RH • 0.25 120 B332I120RHH • • 0.98 277 B332I277RHH • • 0.43 347 B332I347HPL • 0.21 3 PAR-IS 120 0.71 B332IUNVHP-A • • • 277 0.31 347 B332I347HP • 0.25 120 0.61 B332IUNVEL-A • • 277 0.26 120 B332I120EL • • 0.59 277 B332I277EL • • 0.26 120 0.70 B332IUNVHE-A • • 277 0.30 120 B332I120HE • • 0.67 277 B332I277HE • • 0.30 120 0.91 B332IUNVHEH-A • • 277 0.39 347 0.32 3 SER-IS B332IHRVHB-E • • 480 0.24 120 0.77 3 SER-RS B332PUNVHP-A • • • 277 0.34 120 B432I120L-A • • 0.71 277 B432I277L-A • • 0.31 347 B432I347L • 0.24 120 B432I120RES-A* • • • 1.20 120 B432I120RH-A • • • 0.78 277 B432I277RH-A • • • 0.33 347 B432I347RH • 0.28 347 B432I347HPL • 0.24 120 0.77 B432IUNVHP-A • • • 3 PAR-IS 277 0.34 347 B432I347HP • 0.28 120 0.77 B432IUNV-D • • 277 0.33 120 0.67 B432IUNVEL-A • • 277 0.29 120 B432I120EL • • 0.67 277 B432I277EL • • 0.28 120 0.74 B432IUNVHE-A • • 277 0.32 120 B432I120HE • • 0.74 277 B432I277HE • • 0.33 • • 0.43 277 B432I277HEH1 120 0.68 ES1720B • • 277 0.31 120 0.77 3 SER-PRS B432PUNVHP-A • • • 277 0.34 * For Residential Use Only 1 Consult lamp manufacturers for applications with Ballast Factor > 1.20 F32T8 • Low Profile Designs Featured TRIAD® ELECTRONIC BALLASTS FOR (4) F32T8 LAMPS • Instant & Programmed Rapid Starting Options Fluorescent-Electronic • 4 Lamp Applications Lamp Certification Line Input Power Ballast Ballast Starting Line Catalog Current Power Factor Factor Efficacy THD NOM Qty. Method Volts Number (Amps) (Watts) (PF) (BF) Factor (BEF) % F32T8 - Four Lamp Applications 120 B432I120L-A • • 0.85 100 > .98 0.78 0.78 < 20 277 B432I277L-A • • 0.36 98 > .98 0.78 0.80 < 20 347 B432I347L • 0.29 101 > .99 0.78 0.77 < 20 120 B432I120RES-A* • • • 1.40 109 > .50 0.87 0.80 < 130 120 B432I120RH-A • • • 0.93 112 > .99 0.88 0.79 < 20 277 B432I277RH-A • • • 0.40 110 > .98 0.88 0.80 < 20 347 B432I347RH • 0.33 114 > .98 0.88 0.77 < 20 347 B432I347HPL • 0.29 101 > .99 0.78 0.77 < 10 120 0.93 112 > .99 0.79 B432IUNVHP-A • • • 0.88 < 10 277 0.40 108 > .98 0.80 347 B432I347HP • 0.33 114 > .99 0.88 0.77 < 10 120 0.93 111 0.77 B432IUNV-D • • > .98 0.88 < 10 4 PAR-IS 277 0.40 109 0.80 120 0.80 97 > .99 0.79 B432IUNVEL-A • • 0.77 < 10 277 0.34 96 > .98 0.80 120 B432I120EL • • 0.81 95 > .99 0.77 0.81 < 10 277 B432I277EL • • 0.35 93 > .99 0.77 0.83 < 10 120 0.91 109 0.80 B432IUNVHE-A • • > .99 0.87 < 10 277 0.38 106 0.82 120 B432I120HE • • 0.90 106 > .99 0.87 0.82 < 10 277 B432I277HE • • 0.39 105 > .99 0.87 0.83 < 10 277 B432I277HEH • • 0.53 145 > .99 1.18 0.81 < 10 120 0.88 107 0.81 ES1720B • • > .97 0.87 < 10 277 0.40 108 0.82 120 1.00 119 > .99 0.74 4 SER-PRS B432PUNVHP-A • • • 0.88 < 10 277 0.42 115 > .98 0.77 * For Residential Use Only IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Min. F/C Start Wiring Temp Diag. Dim. 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 7a 7a 7 7a 7a 7a 7a 7 -A -A ST -A -A -A ST ST 0/-18 0/-18 7a 7a -A 0/-18 25 -D 0/-18 7a -A 0/-18 0/-18 7a 7a ST ST 0/-18 7a -A 0/-18 0/-18 0/-18 7a 7a 7a ST ST ST 0/-18 38 ESB 0/-18 8 -A ST See page 2-23 for Dimensions and Wiring Diagrams STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start SER-PRS = Series Programmed Rapid Start PAGE 2-22 PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® ELECTRONIC BALLASTS F32T8 FOR F32T8 LAMPS Overall Dimensions Draw # L ST -A -B -C -D -E -G ESA ESB 9.50” 9.50” 9.50” 14.25” 16.88” 16.88” 9.50” 9.50” 9.50” W 2.40” 1.70” 1.50” 1.18” 1.18” 1.74” 1.18” 1.56” 2.38” Mounting Dimensions H M X 1.55” 1.18” 1.00” 1.00” 1.00” 1.18” 1.00” 1.00” 1.00” 8.89” 8.89” 8.89” 13.75” 16.20” 16.28” 8.89” 8.88” 8.88” WIRING DIAGRAMS 1.69” 1.69” 0.88” --------0.78” --- DIAGRAM 1 For Three Lamp Application, Individually cap brown leads, Insulate to 600V DIAGRAM 8 -A, -B, -E, -G ESA, ESB DIAGRAM 2 -C, -D For Two Lamp operation, individually cap yellow leads, Insulate to 600V DIAGRAM 23 DIAGRAM 3 DIAGRAM 21 DIAGRAM 24 DIAGRAM 22 DIAGRAM 3a Line Black White DIAGRAM 37 BALLAST Blue Blue Blue Red DIAGRAM 25 LAMP LAMP LAMP DIAGRAM 39 For Two Lamp operation, Insulate one blue lead to 600V DIAGRAM 6 Line Blue Black White Yellow Yellow BALLAST DIAGRAM 30 Blue Red Red LAMP DIAGRAM 39a LAMP LAMP LAMP For Three Lamp Operation, Insulate one blue lead to 600V DIAGRAM 7 DIAGRAM 40 DIAGRAM 38 For three lamp operation, cap any blue lead, insulate to 600V DIAGRAM 7a DIAGRAM 38a DIAGRAM 46 PAGE 2-23 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic ST F32T8ES 30 WATT • High Performance Models and Low Profile Designs TRIAD® ELECTRONIC BALLASTS • Instant and Programmed Rapid Starting Options FOR (1) & (2) F32T8ES(30 WATT) LAMPS Fluorescent-Electronic • 1-2 Lamp Applications Lamp Certification Starting Line Catalog NOM Qty. Method Volts Number F32T8ES(30W) - One Lamp Applications 277 B132I277RH-A • • 120 B132IUNVHP-B • • 277 1 IS 120 • 277 B132IUNVEL-A • 120 • 277 B132IUNVHE-A • 120 PRS • • 1 277 B132PUNVHP-A • 277 B232I277L-A • 347 B232I347L-A • 120 B232I120RH-A • • • 277 B232I277RH-A • • • 347 B232I347RH-A • 120 • • 1 PAR-IS 277 B232IUNVHP-B • 347 B232I347HP-A • 120 B232IUNVEL-A • • 277 120 B232I120EL • • 277 B232I277EL • • 120 • 277 B232IUNVHE-A • 120 1 • 277 B232IUNVHEH-A • 120 B232I120HE • • 277 B232I277HE • • 120 B232PUNVEL-A • 277 1 120 PRS 277 B232PUNVHE-A • 120 • • 277 B232PUNVHP-A • F32T8ES(30W) - Two Lamp Applications 120 • • 277 B232IUNVEL-A 120 B232I120EL • • 277 B232I277EL • • 120 • 277 B232IUNVHE-A • 120 • 277 B232IUNVHEH-A • 120 B232I120HE • • 277 B232I277HE • • 277 B232I277L-A • 347 B232I347L-A • 2 PAR-IS 120 B232I120RH-A • • • 277 B232I277RH-A • • • 347 B232I347RH-A • 120 B232I120RHH-A • • 277 B232I277RHH-A • • 120 B232IUNVHP-B • • • 277 347 B232I347HP-A • 120 277 B232PUNVEL-A • 120 2 SER-PRS 277 B232PUNVHE-A • 120 • • 277 B232PUNVHP-A • 120 B332I120RH-A • • • 277 B332I277RH-A • • • 120 • • 277 B332IUNVHP-A • 2 PAR-IS 120 • 277 B332IUNVEL-A • 120 B332I120EL • • 277 B332I277EL • • 120 B332IUNVHE-A • • 277 1 Consult lamp manufacturers Line Input Power Ballast Ballast Min. F/C Current Power Factor Factor Efficacy THD Start Wiring (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. 0.11 0.25 0.11 0.22 0.11 0.24 0.12 0.23 0.10 0.12 0.15 0.32 0.15 0.15 0.28 0.12 0.15 0.23 0.11 0.24 0.11 0.25 0.12 0.37 0.16 0.26 0.12 0.19 0.09 0.22 0.10 0.25 0.11 0.38 0.17 0.38 0.17 0.42 0.19 0.59 0.25 0.43 0.19 0.18 0.14 0.47 0.21 0.10 0.63 0.26 0.44 0.19 0.10 0.37 0.16 0.43 0.18 0.50 0.21 0.54 0.23 0.50 0.22 0.46 0.20 0.42 0.19 0.49 0.21 29 29 25 28 28 33 51 35 38 54 33 53 > .97 > .95 > .98 > .95 > .98 > .95 > .99 > .98 > .90 > .98 > .90 > .90 > .98 > .99 > .98 > .98 0.94 3.24 0.77 32 43 30 32 22 23 27 26 30 > .95 > .95 > .98 > .98 > .90 > .90 > .99 > .95 28 28 28 46 44 44 52 51 70 68 51 50 49 48 55 58 34 73 73 53 52 34 45 44 50 49 60 58 63 63 59 54 53 51 50 59 57 PAGE 2-24 > .95 > .98 > .98 > .95 > .98 > .98 > .95 > .95 > .98 > .98 > .95 > .98 > .98 > .98 > .98 > .98 > .98 > .99 > .98 > .98 > .90 > .90 > .99 > .98 > .96 > .97 > .99 > .95 > .99 > .98 > .98 > .98 > .99 > .97 60/16 1 -A 3.08 < 15 <10 < 10 60/16 1 -A 0.87 3.11 < 10 60/16 1 -A 0.88 0.98 0.78 1.10 1.10 0.88 1.05 0.88 3.14 2.97 1.53 3.14 2.89 1.63 3.18 1.66 < 10 < 32 < 20 < 32 < 25 < 20 60/16 60/16 60/16 60/16 60/16 60/16 2 3a 3a 3a 3a 3a -A -A -A -A -A -A 1.05 1.38 1.00 1.03 0.72 0.88 1.00 3.28 3.21 3.33 3.22 3.27 3.12 3.26 3.38 3.33 < 10 < 10 < 10 < 10 60/16 60/16 60/16 3a 3 3 -A ST ST 0.88 0.92 0.89 0.92 0.77 0.77 0.77 0.87 1.18 0.87 0.87 0.77 0.96 0.89 0.89 1.04 1.18 1.18 0.88 1.04 0.71 0.87 0.88 1.01 1.00 0.99 0.89 0.86 0.86 0.99 3.03 3.92 3.18 3.29 1.67 1.75 1.75 1.67 1.71 1.69 1.74 1.71 1.74 1.57 3.10 1.62 1.53 3.06 1.62 1.62 1.66 1.69 3.06 1.59 1.61 1.74 1.78 1.47 1.52 1.60 1.59 1.68 1.65 1.68 1.69 1.72 1.68 1.74 < 10 < 10 60/16 60/16 60/16 60/16 1 3a 3a 3a -B -B -A -A < 10 < 10 < 10 < 10 < 10 60/16 60/16 60/16 60/16 60/16 3a 3 3 30 30 -A ST ST < 10 60/16 30 -A < 10 < 10 < 10 60/16 60/16 60/16 3 3 3 -A ST ST < 10 < 10 < 10 < 20 < 20 < 20 < 20 < 20 <20 <20 60/16 60/16 60/16 60/16 60/16 60/16 60/16 60/16 60/16 60/16 3 3 3 3 3 3 3 3 3 3 -A ST ST -A -A -A -A -A -A -A < 10 < 10 < 10 < 10 < 10 60/16 3 -A -A -A 60/16 60/16 60/16 60/16 3 3 30 30 < 10 < 25 < 25 60/16 60/16 60/16 30 6 6 -A -A -A < 10 < 10 < 10 60/16 60/16 60/16 6 6 6 -A ST ST < 10 < 10 60/16 60/16 6 6 -B -A -A -A -A -A See page 2-30 for Dimensions and Wiring Diagrams FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® ELECTRONIC BALLASTS FOR (2)(cont.), (3) & (4) F32T8ES LAMPS F32T8ES • High Performance Models and Low Profile Designs 30 WATT • Instant and Programmed Rapid Starting Options • 3-4 Lamp Applications IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Line Input Power Ballast Ballast Min. F/C Current Power Factor Factor Efficacy THD Start Wiring (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. 0.47 0.21 0.65 0.28 0.21 0.16 0.51 0.23 57 58 78 76 71 61 60 > .98 > .98 > .95 > .97 > .90 > .99 >.90 0.96 0.99 1.28 0.69 0.30 0.66 0.29 0.58 0.25 0.56 0.24 0.65 0.28 0.63 0.28 0.86 0.37 0.30 0.22 0.73 0.32 0.65 0.71 0.26 0.26 0.72 0.32 0.62 0.27 0.61 0.27 0.70 0.30 0.70 0.31 0.73 0.32 81 81 79 77 70 69 66 65 79 77 76 75 104 101 102 101 87 85 78 85 88 88 86 84 75 73 73 73 84 82 83 84 87 85 > .98 > .98 > .99 > .95 > .99 > .98 > .98 > .99 > .99 > .98 > .98 > .99 > .95 > .98 > .95 > .99 > .95 > .98 > .99 > .98 > .98 > .98 > .95 > .99 > .98 > .98 > .98 0.80 0.87 0.31 0.31 0.87 0.38 0.80 0.34 0.75 0.32 0.91 0.38 0.85 0.37 0.49 0.95 0.41 95 104 106 106 104 101 97 96 89 87 109 106 100 99 134 114 110 > .98 > .99 > .99 > .99 > .98 > .95 > .99 > .98 > .99 > .99 > .98 > .98 > .98 > .99 > .95 > .99 > .99 > .99 > .99 > .99 > .95 60/16 60/16 6 6 ST ST 1.72 1.62 1.65 < 10 60/16 46 -E <10 60/16 23 -A 0.88 0.88 0.89 0.77 0.77 0.77 0.87 0.87 0.87 1.18 1.18 0.88 0.86 0.88 0.99 0.99 0.96 0.86 0.85 0.84 0.96 0.96 0.96 0.93 1.09 1.09 1.13 1.16 1.10 1.12 1.17 1.18 1.10 1.13 1.14 1.16 1.13 1.17 1.16 1.17 1.01 1.04 1.10 1.04 1.13 1.13 1.12 1.14 1.15 1.18 1.16 1.15 1.14 1.17 1.16 1.14 1.07 1.09 < 20 < 20 60/16 60/16 6 6 -A -A < 10 60/16 6 -A 0.80 0.88 0.88 0.88 0.88 0.77 0.77 0.77 0.87 0.87 0.87 1.18 0.88 0.84 0.85 0.83 0.83 0.85 0.87 0.79 0.80 0.87 0.89 0.80 0.82 0.87 0.88 0.88 0.77 0.80 < 10 60/16 6 -A < 10 60/16 6 -A < 10 < 10 60/16 60/16 6 6 ST ST < 10 60/16 6 -A < 10 < 10 60/16 60/16 6 6 ST ST < 10 60/16 6 -A < 10 60/16 46 -E < 10 60/16 23 -A < 20 < 10 < 10 < 20 60/16 60/16 60/16 60/16 7a 7a 7a 7a -A -A ST ST < 10 60/16 7a -A < 10 60/16 7a -A < 10 < 10 60/16 60/16 7a 7a ST ST < 10 60/16 7a -A < 10 < 10 60/16 60/16 7 7 ST ST < 10 60/16 8 -A < 20 < 10 < 10 < 20 60/16 60/16 60/16 60/16 7a 7a 7a 7a -A -A ST ST < 10 60/16 7a -A < 10 60/16 7a -A < 10 < 10 60/16 60/16 7a 7a ST ST < 10 60/16 7a -A < 10 < 10 < 10 60/16 60/16 60/16 7a 7a 7a ST ST ST < 10 60/16 8 -A See page 2-30 for Dimensions and Wiring Diagrams STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start SER-PRS = Series Programmed Rapid Start PAGE 2-25 < 10 < 10 1.22 0.99 1.68 1.71 1.64 1.68 PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start SER-IS = Series Instant Start FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Lamp Certification Starting Line Catalog NOM Qty. Method Volts Number F32T8ES(30W) - Two Lamp Applications 120 B332I120HE • • 2 PAR-IS 277 B332I277HE • • 120 • 277 B332IUNVHEH-A • 347 • 2 SER-IS 480 B332IHRVHB-E • 120 • • 2 SER-PRS 277 B332PUNVHP-A • F32T8ES(30W) - Three Lamp Applications 120 B332I120RH-A • • • 277 B332I277RH-A • • • 120 B332IUNVHP-A • • • 277 3 PAR-IS 120 B332IUNVEL-A • • 277 120 B332I120EL • • 277 B332I277EL • • 120 B332IUNVHE-A • • 277 120 B332I120HE • • 277 B332I277HE • • 120 B332IUNVHEH-A • • 277 347 3 SER-IS B332IHRVHB-E • • 480 120 3 SER-PRS B332PUNVHP-A • • • 277 120 B432I120L-A • 120 B432I120RH-A • • • 347 B432I347HP • 347 B432I347RH • 120 B432IUNVHP-A • • • 277 3 PAR-IS 120 B432IUNVEL-A • • 277 120 B432I120EL • • 277 B432I277EL • • 120 B432IUNVHE-A • • 277 120 B432I120HE • • 277 B432I277HE • • 3 SER-PRS 120 B432PUNVHP-A • • • 277 F32T8ES(30W) - Four Lamp Applications 120 B432I120L-A • 120 B432I120RH-A • • • 347 B432I347HP • 347 B432I347RH • 120 B432IUNVHP-A • • • 277 4 PAR-IS 120 B432IUNVEL-A • • 277 120 B432I120EL • • 277 B432I277EL • • 120 B432IUNVHE-A • • 277 120 B432I120HE • • 277 B432I277HE • • 277 B432I277HEH • • 120 4 SER-PRS B432PUNVHP-A • • • 277 F32T8ES Fluorescent-Electronic (25 WATT) • High Performance Models and Low Profile Designs • 1-2 Lamp Applications TRIAD® ELECTRONIC BALLASTS FOR (1) & (2) F32T8ES (25 WATT) LAMPS Lamp Certification Line Input Power Ballast Ballast Min. F/C Starting Line Catalog Current Power Factor Factor Efficacy THD Start Wiring NOM Qty. Method Volts Number (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. F32T8ES (25W) - One Lamp Applications 120 0.24 B132IUNVHP-B • • 24 > .95 0.88 3.67 < 10 60/16 1 -B 277 0.09 120 0.17 > .98 B132IUNVEL-A • • 20 0.77 3.85 < 10 60/16 1 -A 277 0.07 > .95 120 0.19 > .98 B132IUNVHE-A • • 23 0.87 3.78 < 10 60/16 1 -A 277 0.09 > .95 120 0.23 > .99 B232IUNVHP-B • • • 28 1.05 3.75 < 10 60/16 3a -B 277 0.10 > .98 1 IS 120 0.20 24 > .99 3.96 < 10 B232IUNVEL-A • • 0.95 60/16 3a -A 277 0.09 25 > .95 3.80 < 15 120 B232I120EL • • 0.19 23 > .98 0.89 3.87 < 10 60/16 3a ST 277 B232I277EL • • 0.08 23 > .98 0.92 4.00 < 15 60/16 3a ST 120 0.23 > .98 B232IUNVHE-A • • 27 1.05 3.89 < 10 60/16 3a -A 277 0.10 > .95 0.32 38 3.63 120 • > .95 1.38 < 10 60/16 3a -A B232IUNVHEH-A1 • 277 0.14 37 3.73 120 B232I120HE • • 0.21 25 > .98 1.00 4.00 < 10 60/16 3 ST 277 B232I277HE • • 0.90 24 > .98 1.03 4.29 < 10 60/16 3 ST 120 0.21 B132PUNVHP-A • • • 25 > .99 0.88 3.52 < 10 60/16 2 -A 277 0.09 120 0.16 19 3.74 0.71 < 10 60/16 30 -A 277 B232PUNVEL-A • 0.08 19 > .90 3.74 1 PRS 120 0.20 25 3.52 0.88 < 10 60/16 30 -A 277 B232PUNVHE-A • 0.09 24 > .90 3.67 120 0.22 > .99 B232PUNVHP-A • • • 27 1.00 3.70 < 10 60/16 30 -A 277 0.10 >.94 F32T8ES (25W) - Two Lamp Applications 120 0.37 44 > .99 2.00 B232IUNVHP-B • • • 0.88 < 10 60/16 3 -B 277 0.16 43 > .98 2.05 120 0.33 39 > .99 1.97 B232IUNVEL-A • • 0.77 < 10 60/16 3 -A 277 0.14 38 > .98 2.03 120 B232I120EL • • 0.31 37 > .98 0.77 2.08 < 10 60/16 3 ST 277 B232I277EL • • 0.14 37 > .98 0.77 2.08 < 10 60/16 3 ST 120 0.37 44 1.98 B232IUNVHE-A • • > .98 0.87 < 10 60/16 3 -A 277 0.16 43 2.02 120 0.49 59 2.00 B232IUNVHEH-A • • > .95 1.18 < 10 60/16 3 -A 277 0.21 58 2.03 120 B232I120HE • • 0.34 41 > .98 0.87 2.12 < 10 60/16 3 ST 277 B232I277HE • • 0.15 41 > .98 0.87 2.12 < 10 60/16 3 ST 2 PAR-IS 120 0.43 > .98 B332IUNVHP-A • • • 51 1.00 1.96 < 10 60/16 6 -A 277 0.20 > .90 120 0.37 44 > .99 2.02 B332IUNVEL-A • • 0.89 < 10 60/16 6 -A 277 0.16 43 > .95 2.07 120 B332I120EL • • 0.35 42 > .98 0.86 2.05 < 10 60/16 6 ST 277 B332I277EL • • 0.16 43 > .98 0.86 2.00 < 10 60/16 6 ST 120 0.43 51 > .98 1.94 B332IUNVHE-A • • 0.99 < 10 60/16 6 -A 277 0.19 50 > .95 1.98 120 B332I120HE • • 0.40 48 > .98 0.96 2.00 < 10 60/16 6 ST 277 B332I277HE • • 0.17 48 > .99 0.99 2.06 < 10 60/16 6 ST 120 0.55 66 1.94 1 B332IUNVHEH-A • • > .95 1.28 < 10 60/16 6 -A 277 0.25 65 1.97 347 0.18 > .95 B332IHRVH-E • • 61 1.14 1.87 < 10 60/16 46 -E 480 0.14 > .90 120 0.43 52 > .99 1.69 2 SER-IS B232PUNVHP-A • • • 0.88 < 10 60/16 30 -A 277 0.19 51 > .98 1.73 120 0.42 > .99 B332PUNVHP-A • • • 50 0.99 1.98 < 10 60/16 23 -A 277 0.20 > .90 120 0.32 38 1.87 B232PUNVEL-A • > .90 0.71 < 10 60/16 30 -A 277 0.14 38 1.87 2 SER-PRS 120 0.37 44 1.98 0.87 < 10 60/16 30 -A 277 B232PUNVHE-A • 0.16 41 > .90 2.02 1 Consult lamp manufacturers for applications with Ballast Factor > 1.20 See page 2-30 for Dimensions and Wiring Diagrams PAGE 2-26 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® ELECTRONIC BALLASTS FOR (3) & (4) F32T8ES (25 WATT) LAMPS Line Input Power Ballast Ballast Min. F/C Current Power Factor Factor Efficacy THD Start Wiring (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. 0.57 0.26 0.48 0.21 0.47 0.20 0.24 0.60 0.54 0.23 0.72 0.32 0.26 0.19 0.61 0.27 0.51 0.22 0.60 0.26 0.57 0.25 0.61 0.27 0.62 0.28 69 68 58 57 56 56 66 65 64 64 87 85 88 73 72 61 61 72 71 68 69 73 71 75 73 > .99 > .95 > .99 > .97 > .98 > .98 > .98 > .95 > .98 > .99 > .95 > .97 > .90 > .98 > .95 > .98 > .98 > .99 > .95 > .99 > .99 > .99 > .95 > .99 > .95 0.90 0.77 0.77 0.77 0.87 0.87 0.87 1.18 1.11 0.97 0.85 0.87 0.96 0.96 0.96 0.88 0.93 1.30 1.32 1.33 1.35 1.38 1.38 1.32 1.34 1.36 1.36 1.36 1.39 1.26 0.74 0.33 0.62 0.26 90 88 74 72 > .98 > .95 > .98 > .98 0.89 0.77 0.77 0.99 1.01 1.04 1.07 4 PAR-IS 120 0.73 B432IUNVHE-A • • 277 0.31 120 B432I120HE • • 0.70 277 B432I277HE • • 0.30 120 0.84 4 SER-PRS B432PUNVHP-A • • • 277 0.36 1 Consult lamp manufacturers for applications with Ballast Factor > 1.20 IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start (25 WATT) • 3-4 Lamp Applications 87 85 84 84 100 98 > .99 > .98 > .99 > .99 > .99 > .95 1.00 1.02 1.04 1.04 0.88 0.90 60/16 6 -A < 10 60/16 6 -A < 10 < 10 60/16 60/16 6 6 ST ST < 10 60/16 6 -A < 10 < 10 60/16 60/16 6 6 ST ST < 10 60/16 6 -A < 10 60/16 46 -E < 10 60/16 7a -A < 10 < 10 60/16 60/16 7 7 ST ST < 10 60/16 7a -A < 10 < 10 60/16 60/16 7a 7a ST ST < 10 60/16 23 -A < 10 60/16 8 -A < 10 60/16 7a -A < 10 < 10 60/16 60/16 7a 7a ST ST <10 60/16 7a -A < 10 < 10 < 10 60/16 60/16 7a 7a ST ST 60/16 8 -A See page 2-30 for Dimensions and Wiring Diagrams STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start SER-PRS = Series Programmed Rapid Start PAGE 2-27 0.87 0.87 0.87 0.88 1.33 1.35 1.39 1.43 1.33 1.35 1.41 1.39 1.21 1.24 1.24 1.27 < 10 PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start SER-IS = Series Instant Start FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Lamp Certification Starting Line Catalog NOM Qty. Method Volts Number F32T8ES (25W) - Three Lamp Applications 120 B332IUNVHP-A • • • 277 120 B332IUNVEL-A • • 277 120 B332I120EL • • 3 PAR-IS 277 B332I277EL • • 120 B332IUNVHE-A • • 277 120 B332I120HE • • 277 B332I277HE • • 120 B332IUNVHEH-A • • 277 347 3 SER-IS B332IHRVHB-E • • 480 120 B432IUNVHP-A • • • 277 120 B432I120EL • • 3 PAR-IS 277 B432I277EL • • 120 B432IUNVHE-A • • 277 120 B432I120HE • • 274 B432I277HE • • 120 B332PUNVHP-A • • • 277 3 SER-PRS 120 B432PUNVHP-A • • • 277 F32T8ES (25W) - Four Lamp Applications 120 B432IUNVHP-A • • • 277 120 B432I120EL • • 277 B432I277EL • • F32T8ES • High Performance Models and Low Profile Designs F28T8 TRIAD® ELECTRONIC BALLASTS FOR (1) & (2) F28T8 LAMPS • High Performance Models and Low Profile Designs • Instant and Programmed Rapid Starting Options Fluorescent-Electronic • 1-2 Lamp Applications Lamp Certification Line Input Power Ballast Ballast Min. F/C Starting Line Catalog Current Power Factor Factor Efficacy THD Start Wiring NOM Qty. Method Volts Number (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. F28T8 - One Lamp Applications 277 B132I277RH-A • • 0.10 27 > .98 0.97 3.59 < 20 60/16 1 -A 120 0.21 B132IUNVHP-B • • 26 > .95 0.88 3.38 < 10 60/16 1 -B 277 0.09 120 0.20 > .98 B132IUNVEL-A • • 21 0.77 3.67 < 10 60/16 1 -A 277 0.10 > .95 120 0.20 > .98 B132IUNVHE-A • • 24 0.87 3.63 < 10 60/16 1 -A 277 0.10 > .95 277 B232I277L-A • • 0.12 30 > .90 0.96 3.20 < 32 60/16 3a -A 347 B232I347L-A • 0.08 29 > .98 0.96 3.31 < 20 60/16 3a -A 120 B232I120RH-A • • • 0.30 33 > .90 1.10 3.33 < 32 60/16 3a -A 277 B232I277RH-A • • • 0.13 33 > .90 1.10 3.33 < 32 60/16 3a -A 1 IS 347 B232I347RH-A • 0.09 32 > .98 1.04 3.25 < 20 60/16 3a -A 120 0.26 31 > .99 3.39 B232IUNVHP-B • • • 1.05 < 10 60/16 3a -B 277 0.11 30 > .98 3.50 347 B232I347HP-A • 0.09 32 > .98 0.88 3.25 < 10 60/16 3a -A 120 0.22 26 3.65 B232IUNVEL-A • • > .95 0.95 < 10 60/16 3a -A 277 0.10 27 3.52 120 B232I120EL • • 0.23 28 > .98 0.92 3.29 < 10 60/16 3a ST 277 B232I277EL • • 0.09 26 > .98 0.92 3.54 < 10 60/16 3a ST 120 0.24 B232IUNVHE-A • • 29 > .95 1.10 3.79 < 10 60/16 3a -A 277 0.11 120 0.33 40 3.45 B232IUNVHEH-A1 • • > .95 1.38 < 10 60/16 3a -A 277 0.15 39 3.54 120 B232I120HE • • 0.23 28 > .98 1.01 3.61 < 10 60/16 3a ST 277 B232I277HE • • 0.12 29 > .98 1.02 3.52 < 10 60/16 3a ST 120 0.28 B132PUNVHP-A • • • 27 > .99 0.88 3.26 < 10 60/16 2 -A 277 0.11 120 0.18 21 3.38 0.71 < 10 60/16 30 -A 277 B232PUNVEL-A • 0.08 21 > .90 3.38 PRS 1 120 0.21 25 3.49 0.88 < 10 60/16 30 -A 277 B232PUNVHE-A • 0.09 24 > .90 3.67 120 0.25 > .99 B232PUNVHP-A • • • 30 1.00 3.33 < 10 60/16 30 -A 277 0.11 >.95 F28T8 - Two Lamp Applications 277 B232I277L-A • • 0.17 45 > .95 0.75 1.67 < 25 60/16 3 -A 347 B232I347L-A • 0.13 44 > .98 0.78 1.77 < 20 60/16 3 -A 120 B232I120RH-A • • • 0.43 51 > .98 0.90 1.76 < 20 60/16 3 -A 277 B232I277RH-A • • • 0.19 51 > .98 0.90 1.76 < 20 60/16 3 -A 347 B232I347RH-A • 0.14 50 > .98 0.88 1.76 < 20 60/16 3 -A 120 0.41 48 > .99 1.83 B232IUNVHP-B • • • 0.88 < 10 60/16 3 -B 277 0.17 47 > .98 1.87 347 B232I347HP-A • 0.14 50 > .98 1.04 1.76 < 10 60/16 3 -A 120 0.36 B232IUNVEL-A • • 43 > .95 0.77 1.79 < 10 60/16 3 -A 277 0.15 120 B232I120EL • • 0.35 41 > .98 0.77 1.88 < 10 60/16 3 ST 277 B232I277EL • • 0.14 41 > .98 0.77 1.88 < 10 60/16 3 ST 120 0.40 49 1.78 B232IUNVHE-A • • > .95 0.87 < 10 60/16 3 -A 2 PAR-IS 277 0.18 48 1.81 120 0.53 64 1.84 B232IUNVHEH-A • • > .95 1.18 < 10 60/16 3 -A 277 0.23 62 1.90 120 B232I120HE • • 0.38 48 > .98 0.87 1.81 < 10 60/16 3 ST 277 B232I277HE • • 0.17 47 > .98 0.87 1.85 < 10 60/16 3 ST 120 B332I120RH-A • • • 0.50 57 > .95 1.02 1.79 < 32 60/16 6 -A 277 B332I277RH-A • • • 0.22 57 > .95 1.00 1.75 < 25 60/16 6 -A 120 0.46 55 > .99 1.80 B332IUNVHP-A • • • 0.99 < 10 60/16 6 -A 277 0.21 54 > .90 1.83 120 0.41 49 > .99 1.82 B332IUNVEL-A • • 0.89 < 10 60/16 6 -A 277 0.18 48 > .95 1.85 120 B332I120EL • • 0.38 45 > .98 0.86 1.91 < 10 60/16 6 ST 277 B332I277EL • • 0.18 47 > .98 0.88 1.87 < 10 60/16 6 ST 120 0.45 54 > .99 1.83 B332IUNVHE-A • • 0.99 < 10 60/16 6 -A 277 0.19 53 > .97 1.87 120 0.57 71 1.80 B332IUNVHEH-A1 • • > .95 1.28 < 10 60/16 6 -A 277 0.27 69 1.86 1 Consult lamp manufacturers for applications with Ballast Factors > 1.20 See page 2-30 for Dimensions and Wiring Diagrams PAGE 2-28 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® ELECTRONIC BALLASTS FOR (2)(cont.), (3) & (4) F28T8 LAMPS F28T8 • High Performance Models and Low Profile Designs • Instant and Programmed Rapid Starting Options • 2-4 Lamp Applications IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Line Input Power Current Power Factor (Amps) (Watts) (PF) 0.42 51 > .98 0.20 52 > .98 0.19 > .97 65 0.15 > .90 0.25 > .99 30 0.11 > .95 0.34 41 0.15 40 > .90 0.39 47 0.17 46 > .90 0.46 55 > .99 0.21 54 > .90 Ballast Ballast Min. F/C Factor Efficacy THD Start Wiring (BF) Factor (BEF) % Temp Diag. Dim. 0.96 1.88 < 10 60/16 6 ST 0.98 1.88 < 10 60/16 6 ST 1.22 1.00 0.70 0.87 0.99 1.88 < 10 60/16 46 -E 3.33 < 10 60/16 30 -A 1.71 1.75 1.85 1.89 1.80 1.83 < 10 < 10 60/16 60/16 30 30 -A < 10 60/16 23 -A -A 0.63 0.27 0.61 0.27 0.53 0.23 0.50 0.22 0.60 0.26 0.57 0.24 0.78 0.34 0.28 0.21 0.23 0.23 0.66 0.29 0.57 0.26 0.25 0.64 0.28 0.28 0.66 0.29 0.68 0.30 74 74 73 71 66 65 62 61 75 73 72 71 95 92 94 78 78 79 77 69 68 66 77 75 74 79 78 82 80 > .98 > .98 > .99 > .95 > .99 > .97 > .98 > .98 > .99 > .98 > .98 > .98 > .95 > .97 > .90 > .98 > .98 > .98 > .95 > .99 > .95 > .98 > .99 > .98 > .98 > .99 > .95 > .99 > .95 0.88 0.88 0.89 0.77 0.77 0.77 0.87 0.87 0.87 1.18 1.18 0.99 0.99 0.97 0.97 0.86 0.88 0.96 0.98 0.88 0.93 1.19 1.19 1.22 1.25 1.17 1.18 1.24 1.26 1.16 1.19 1.21 1.23 1.24 1.28 1.26 < 20 < 20 60/16 60/16 6 6 -A -A < 10 60/16 6 -A 1.27 1.27 1.23 1.26 1.25 1.26 1.33 1.25 1.28 1.32 1.11 1.13 1.13 1.16 < 10 0.28 0.28 0.80 0.35 0.70 0.31 0.75 0.29 0.77 0.33 0.85 0.32 0.45 0.89 0.39 95 95 96 93 85 84 83 81 97 94 94 93 123 107 104 > .99 > .99 > .98 > .95 > .99 > .98 > .99 > .98 > .99 > .98 > .99 > .98 > .99 > .99 > .95 0.88 0.88 0.89 0.88 0.77 0.77 0.77 0.87 0.87 0.87 1.18 0.88 0.93 0.93 0.93 0.95 0.91 0.92 0.93 0.95 0.90 0.93 0.93 0.94 0.96 0.82 0.85 60/16 6 -A 60/16 60/16 6 6 ST ST < 10 60/16 6 -A < 10 < 10 60/16 60/16 6 6 ST ST < 10 60/16 6 -A < 10 60/16 46 -E < 10 < 10 60/16 60/16 7a 7a ST ST 60/16 7a -A < 10 60/16 7a -A < 10 60/16 7a ST < 10 60/16 7a -A < 10 60/16 7a ST < 10 60/16 23 -A < 10 60/16 8 -A < 10 < 20 60/16 60/16 7a 7a ST ST < 10 60/16 7a -A < 10 60/16 7a -A < 10 < 10 60/16 60/16 7a 7a ST ST < 10 60/16 7a -A < 10 < 10 < 10 60/16 60/16 60/16 7a 7a 7a ST ST ST < 10 60/16 8 -A See page 2-30 for Dimensions and Wiring Diagrams STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start SER-PRS = Series Programmed Rapid Start PAGE 2-29 < 10 < 10 < 10 PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start SER-IS = Series Instant Start FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Lamp Certification Starting Line Catalog NOM Qty. Method Volts Number 120 B332I120HE • • 2 PAR-IS 277 B332I277HE • • 347 1 • • 2 SER-IS B332IHRVH-E 480 120 B232PUNVHP-A • • • 277 120 277 B232PUNVEL-A • 2 SER-PRS 120 277 B232PUNVHE-A • 120 B332PUNVHP-A • • • 277 F28T8 - Three Lamp Applications 120 B332I120RH-A • • • 277 B332I277RH-A • • • 120 B332IUNVHP-A • • • 277 120 B332IUNVEL-A • • 3 PAR-IS 277 120 B332I120EL • • 277 B332I277EL • • 120 B332IUNVHE-A • • 277 120 B332I120HE • • 277 B332I277HE • • 120 B332IUNVHEH-A • • 277 347 3 SER-IS B332IHRVHB-E • • 480 347 B432I347RH • 347 B432I347HP • 120 B432IUNVHP-A • • • 277 120 B432IUNVEL-A • • 277 277 B432I277EL • • 120 B432IUNVHE-A • • 277 277 B432I277HE • • 120 B332PUNVHP-A • • • 277 3 SER-PRS 120 B432PUNVHP-A • • • 277 F28T8 - Four Lamp Applications 347 B432I347HP • 347 B432I347RH • 120 B432IUNVHP-A • • • 277 120 B432IUNVEL-A • • 277 120 B432I120EL • • 277 B432I277EL • • 4 PAR-IS 120 B432IUNVHE-A • • 277 120 B432I120HE • • 277 B432I277HE • • 277 B432I277HEH • • 120 4 SER-PRS B432PUNVHP-A • • • 277 F32T8ES TRIAD® ELECTRONIC BALLASTS & FOR F32T8ES AND F28T8 LAMPS F28T8 Overall Dimensions Draw # L ST -A -E 9.50” 9.50” 16.88” W 2.40” 1.70” 1.74” Mounting Dimensions H M X 1.55” 1.18” 1.18” 8.89” 8.89” 16.28” WIRING DIAGRAMS 1.69” 1.69” --- DIAGRAM 1 For three lamp operation, cap any blue lead, insulate to 600V Fluorescent-Electronic ST DIAGRAM 7a DIAGRAM 2 -A, -E For Three Lamp Application, Individually cap brown leads, Insulate to 600V DIAGRAM 8 DIAGRAM 3 For Two Lamp operation, individually cap yellow leads, Insulate to 600V DIAGRAM 3a Line Black White BALLAST DIAGRAM 23 Blue Blue Blue Red LAMP LAMP LAMP For Two Lamp operation, Insulate one blue lead to 600V DIAGRAM 6 Line DIAGRAM 30 Blue Black White BALLAST Yellow Yellow Blue Red Red LAMP LAMP LAMP LAMP For Three Lamp Operation, Insulate one blue lead to 600V DIAGRAM 7 PAGE 2-30 DIAGRAM 46 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® ELECTRONIC BALLASTS FOR (1), (2), AND (3) F40T8 LAMPS F40T8 • Low Profile Designs Featured • Instant & Programmed Rapid Starting Options • 1-3 Lamp Applications Ballast Ballast Min. F/C Factor Efficacy THD Start Wiring (BF) Factor (BEF) % Temp Diag. Dim. 0.83 0.83 < 15 < 15 50/10 50/10 1 1 -A -A 0.85 2.37 2.24 2.30 2.36 < 10 32/0 1 -B 0.76 2.38 < 10 0/-18 1 -A 0.86 2.46 < 10 0/-18 1 -A 0.91 0.91 0.95 1.03 1.03 1.02 0.86 1.03 1.02 < 25 < 25 < 20 < 25 < 25 <10 < 10 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 3a 3a 3a 3a 3a 3a 3a -A -A -A -A -A -A ST < 10 < 20 32/0 0/-18 3a 3a -B -A 0.99 0.71 0.84 1.05 0.87 2.28 2.28 2.50 2.29 2.29 2.27 2.26 2.40 2.45 2.27 2.30 2.36 2.37 2.45 2.33 2.40 2.84 2.69 1.98 < 10 0/-18 22 -C < 10 0/-18 30 -A < 10 0/-18 30 -A < 10 0/-18 37 ESA < 10 0/-18 37 ESA 0.91 0.87 0.89 0.82 0.96 1.00 0.82 0.95 0.89 0.99 1.26 1.20 1.23 1.24 1.18 1.17 1.22 1.19 1.22 1.23 1.31 1.35 1.29 1.32 1.25 1.25 < 10 < 20 < 20 < 20 < 20 < 20 < 10 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 14 6 6 6 6 6 6 ST -A -A ST -A -A ST < 10 0/-18 6 -A < 10 0/-18 6 -A < 10 0/-18 6 -A < 10 0/-18 6 -A 0.84 0.81 0.90 0.90 0.81 0.92 0.94 0.86 0.96 0.84 0.81 0.80 0.83 0.81 0.81 0.84 0.84 0.86 0.89 0.91 0.86 0.90 < 20 < 20 < 10 < 10 < 10 0/-18 0/-18 0/-18 0/-18 0/-18 7a 7 7a 7a 7 -A ST -A -A ST < 10 0/-18 7a -A < 10 0/-18 24 -D < 10 0/-18 7a -A < 10 0/-18 7a -A See page 2-32 for Dimensions and Wiring Diagrams PAGE 2-31 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Lamp Certification Line Input Power Starting Line Catalog Current Power Factor NOM Qty. Method Volts Number (Amps) (Watts) (PF) F40T8 - One Lamp Applications 120 B132I120RH-A • • • 0.30 35 > .96 277 B132I277RH-A • • 0.13 37 > .95 120 0.31 37 B132IUNVHP-B • • > .95 277 0.13 36 120 0.25 > .98 B132IUNVEL-A • • 32 277 0.13 > .95 120 0.30 > .98 B132IUNVHE-A • • 35 277 0.14 > .95 120 B232I120L-A • • 0.34 40 > .95 277 B232I277L-A • • 0.15 40 > .95 347 B232I347L-A • 0.11 38 > .98 1 IS 120 B232I120RH-A • • • 0.38 45 > .95 277 B232I277RH-A • • • 0.17 45 > .95 347 B232I347HP-A • 0.13 45 > .98 347 B232I347HPL • 0.11 38 > .98 120 0.36 43 > .99 B232IUNVHP-B • • • 277 0.15 42 > .98 347 B232I347RH-A • 0.13 45 > .98 120 0.37 43 B232IUNV-C • • > .98 277 0.16 42 120 0.25 30 B232PUNVEL-A • > .90 277 0.11 29 120 0.30 36 B232PUNVHE-A • > .90 1 PRS 277 0.13 35 120 0.31 37 ES4800A • • > .97 277 0.14 39 347 ES1679A • 0.13 44 > .97 F40T8 - Two Lamp Applications 347 B259I347HP • 0.22 76 > .98 120 B332I120L-A • • 0.60 71 > .98 277 B332I277L-A • • 0.26 72 > .98 347 B332I347L • 0.20 69 > .99 120 B332I120RH-A • • • 0.73 82 > .98 277 B332I277RH-A • • • 0.31 82 > .98 2 PAR-IS 347 B332I347HPL • 0.20 69 > .99 120 0.65 78 > .99 B332IUNVHP-A • • • 277 0.29 77 > .95 120 0.57 68 > .99 B332IUNVEL-A • • 277 0.25 66 > .98 120 0.64 77 > .99 B332IUNVHE-A • • 277 0.27 75 > .98 120 0.84 101 B332IUNVHEH-A • • > .95 277 0.36 101 F40T8 - Three Lamp Applications 120 B432I120L-A • • 0.84 100 > .98 347 B432I347L • 0.29 100 > .99 120 B432I120RH-A • • • 0.93 112 > .99 277 B432I277RH-A • • • 0.40 109 > .99 347 B432I347HPL • 0.29 100 > .99 120 0.95 114 > .99 3 PAR-IS B432IUNVHP-A • • • 277 0.41 109 > .98 120 0.94 112 B432IUNV-D • • > .98 277 0.40 109 120 0.81 97 > .99 B432IUNVEL-A • • 277 0.35 94 > .98 120 0.93 111 > .99 B432IUNVHE-A • • 277 0.39 107 > .98 TRIAD® ELECTRONIC BALLASTS F40T8 FOR F40T8 LAMPS Overall Dimensions Draw # L ST -A -B -C -D ESA 9.50” 9.50” 9.50” 14.25” 16.88” 9.50” W 2.40” 1.70” 1.50” 1.18” 1.18” 1.56” Mounting Dimensions H M X 1.55” 1.18” 1.00” 1.00” 1.00” 1.00” 8.89” 8.89” 8.89” 13.75” 16.20” 8.88” WIRING DIAGRAMS 1.69” 1.69” 0.88” ----0.78” Line Blue Black White Yellow Yellow BALLAST Blue Red Red LAMP LAMP LAMP LAMP For Three Lamp Operation, Insulate one blue lead to 600V Fluorescent-Electronic DIAGRAM 1 DIAGRAM 7 -A, -B, ESA ST -C, -D For three lamp operation, cap any blue lead, insulate to 600V DIAGRAM 3a DIAGRAM 7a Line Black White BALLAST Blue Blue Blue Red LAMP LAMP LAMP For Two Lamp Operation, Insulate one blue lead to 600V DIAGRAM 14 DIAGRAM 6 DIAGRAM 22 DIAGRAM 24 DIAGRAM 37 PAGE 2-32 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® ELECTRONIC BALLASTS • Instant Starting Options FOR (1) AND (2) F48T8, F72T8, F96T8 AND F96T8ES LAMPS • 8’ T8 SLIMLINE • 1-2 Lamp Applications STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start ST SL -A 9.50” 11.75” 9.50” W 2.40” 3.13” 1.70” Mounting Dimensions H M X 1.55” 1.78” 1.18” 8.89” 11.14” 8.89” 1.07 1.07 3.15 3.06 < 10 < 10 0/-18 0/-18 14 14 ST ST 0.90 0.90 1.61 1.64 < 10 < 10 0/-18 0/-18 14 14 ST ST 1.05 1.05 2.10 2.06 < 10 < 10 0/-18 0/-18 14 14 ST ST 0.88 0.88 1.05 1.07 < 10 < 10 0/-18 0/-18 14 14 ST ST 0.88 0.88 1.05 1.05 0.92 0.92 1.08 1.05 1.05 1.05 1.52 1.52 1.54 1.54 1.53 1.53 1.50 1.52 1.54 1.53 1.52 < 20 < 20 < 25 < 20 < 10 < 10 50/10 50/10 50/10 50/10 50/10 50/10 13 13 14 14 14 14 ST ST ST ST ST ST < 10 < 10 < 10 < 10 32/0 32/0 32/0 32/0 14 14 13 13 -A ST ST ST 0.88 0.88 1.18 1.18 0.78 0.78 0.88 0.89 0.88 0.88 0.79 0.79 0.79 0.79 0.78 0.78 0.78 0.80 0.79 0.81 0.83 < 20 < 20 < 20 < 20 < 10 < 10 50/10 50/10 32/0 32/0 50/10 50/10 14 14 14 14 14 14 ST ST SL SL ST ST < 10 < 10 < 10 < 10 32/0 32/0 32/0 32/0 14 14 14 14 -A ST ST ST 1.05 1.05 1.66 1.66 < 10 < 10 60/16 60/16 13 13 ST ST 1.18 1.18 0.88 0.88 0.83 0.86 0.86 0.88 < 20 < 20 < 10 < 10 60/16 60/16 60/16 60/16 14 14 14 14 SL SL ST ST PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start WIRING DIAGRAMS 1.69” 2.00” 1.69” DIAGRAM 13 ST, SL Ballast Ballast Min. F/C Factor Efficacy THD Start Wiring (BF) Factor (BEF) % Temp Diag. Dim. -A For One Lamp Operation, Insulate one blue lead to 600V DIAGRAM 14 PAGE 2-33 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Overall Dimensions Draw # L SLIMLINE • High Performance Models Lamp Certification Line Input Power Starting Line Catalog Current Power Factor NOM Qty. Method Volts Number (Amps) (Watts) (PF) F48T8 - One Lamp Applications 120 B259I120HE • • 0.29 34 > .98 1 IS 277 B259I277HE • • 0.16 35 > .97 F48T8 - Two Lamp Applications 120 B259I120HE • • 0.47 56 > .99 2 PAR-IS 277 B259I277HE • • 0.20 55 > .97 F72T8 - One Lamp Applications 120 B259I120HE • • 0.42 50 > .99 1 IS 120 B259I277HE • • 0.19 51 > .97 F72T8 - Two Lamp Applications 277 B259I120HE • • 0.71 84 > .99 2 PAR-IS 277 B259I277HE • • 0.30 82 > .97 F96T8 - One Lamp Applications 120 B159I120RH • • 0.52 58 > .96 277 B159I277RH • • 0.22 58 > .96 120 B259I120RH • • • 0.62 68 > .97 277 B259I277RH • • • 0.26 68 > .97 1 IS 120 B259I120HPL • • 0.51 60 > .98 277 B259I277HPL • • 0.22 60 > .98 120 0.60 72 > .99 B259IUNVHP-A • • • 277 0.26 71 > .98 347 B259I347HP • 0.20 68 > .97 120 B259I120HE • • 0.58 69 > .97 277 B259I277HE • • 0.25 69 > .97 F96T8 - Two Lamp Applications 120 B259I120RH • • • 0.95 112 > .98 277 B259I277RH • • • 0.41 112 > .98 120 B259I120RHH • • 1.30 150 > .98 277 B259I277RHH • • 0.56 150 > .98 120 B259I120HPL • • 0.84 100 > .98 2 PAR-IS 277 B259I277HPL • • 0.36 100 > .98 120 0.95 113 > .99 B259IUNVHP-A • • • 277 0.40 110 > .98 347 B259I347HP • 0.33 113 > .99 120 B259I120HE • • 0.92 108 > .99 277 B259I277HE • • 0.38 106 > .99 F96T8ES - One Lamp Applications 120 B259I120HE • • 0.53 63 > .97 1 PAR-IS 277 B259I277HE • • 0.23 63 > .97 F96T8ES - Two Lamp Applications 120 B259I120RHH • • 1.20 142 > .98 277 B259I277RHH • • 0.50 138 > .98 2 PAR-IS 120 B259I120HE • • 0.85 102 > .99 277 B259I277HE • • 0.36 100 > .99 IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start T8 Slimline Lamps T8HO • Instant Starting Options • 1-2 Lamp Applications High Output Lamps TRIAD® ELECTRONIC BALLASTS FOR (1) AND (2) F48T8HO, F60T8HO, F72T8HO AND F96T8HO LAMPS • 4-8’ T8 High Output Fluorescent-Electronic Lamp Certification Line Input Power Starting Line Catalog Current Power Factor NOM Qty. Method Volts Number (Amps) (Watts) (PF) F48T8HO - One Lamp Applications 120 B286I120RH • • • 0.47 48 > .90 1 IS 277 B286I277RH • • • 0.20 47 > .90 F60T8HO - One Lamp Applications 120 B286I120RH • • • 0.56 60 > .90 1 IS 277 B286I277RH • • • 0.23 57 > .90 F72T8HO - One Lamp Applications 120 B286I120RH • • • 0.64 71 > .90 1 IS 277 B286I277RH • • • 0.26 67 > .90 F96T8HO - One Lamp Applications 120 B286I120RH • • • 0.79 92 > .90 1 IS 277 B286I277RH • • • 0.32 87 > .90 F48T8HO - Two Lamp Applications 120 B286I120RH • • • 0.70 80 > .95 2 PAR-IS 277 B286I277RH • • • 0.30 77 > .90 F60T8HO - Two Lamp Applications 120 B286I120RH • • • 0.85 99 > .95 2 PAR-IS 277 B286I277RH • • • 0.36 96 > .95 F72T8HO - Two Lamp Applications 120 B286I120RH • • • 1.00 117 > .95 2 PAR-IS 277 B286I277RH • • • 0.42 114 > .95 F96T8HO - Two Lamp Applications 120 B286I120RH • • • 1.30 151 > .95 2 PAR-IS 277 B286I277RH • • • 0.53 144 > .95 SL 11.75” W 3.13” Mounting Dimensions H M X 1.78” 1.00 1.00 2.08 2.13 < 30 -20/-29 < 30 -20/-29 3 3 SL SL 0.99 0.98 1.65 1.72 < 30 -20/-29 < 30 -20/-29 3 3 SL SL 0.98 0.98 1.38 1.46 < 30 -20/-29 < 30 -20/-29 3 3 SL SL 0.96 0.93 1.04 1.07 < 25 -20/-29 < 25 -20/-29 3 3 SL SL 0.85 0.84 1.06 1.09 < 25 -20/-29 < 25 -20/-29 3 3 SL SL 0.85 0.84 0.86 0.88 < 20 -20/-29 < 20 -20/-29 3 3 SL SL 0.85 0.84 0.73 0.74 < 20 -20/-29 < 20 -20/-29 3 3 SL SL 0.81 0.81 0.54 0.56 < 20 -20/-29 < 20 -20/-29 3 3 SL SL STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Overall Dimensions Draw # L Ballast Ballast Min. F/C Factor Efficacy THD Start Wiring (BF) Factor (BEF) % Temp Diag. Dim. 11.14” PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start WIRING DIAGRAMS 2.00” SL For One Lamp Operation, Insulate one blue lead to 600V DIAGRAM 3 PAGE 2-34 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® T5 ELECTRONIC BALLASTS FOR F8, F13, F14, F21 AND F24 LAMPS IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Line Input Power Ballast Ballast Min. F/C Current Power Factor Factor Efficacy THD Start Wiring (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. 0.18 10 > .50 1.30 13.00 < 150 0/-18 47 CBT 0.34 22 > .50 1.30 5.91 < 150 0/-18 47 CBT 0.25 15 > .50 1.10 9.33 < 150 0/-18 47 CBT 0.48 28 > .50 1.10 3.93 < 150 0/-18 48 CBT 0.15 0.07 0.14 0.07 0.15 0.07 0.25 18 16 17 19 20 16 > .98 > .90 > .98 > .85 1.05 0.89 1.00 0.97 5.83 5.56 5.24 5.26 5.00 6.06 < 10 < 15 < 15 < 20 0/-18 37 -C 0/-18 37 -C < 10 0/-18 < 150 0/-18 40 ESX 0.28 0.13 0.24 0.11 0.25 0.11 0.31 0.13 0.46 34 29 31 37 36 30 > .98 > .95 > .99 > .90 > .99 > .98 > .99 > .98 > .50 1.00 2.94 < 10 37 -C 0.89 3.07 < 10 < 15 0/-18 0/-18 37 -C 0.95 3.06 < 10 0/-18 37 -D < 10 0/-18 37 -D 0.21 0.10 0.19 0.09 0.20 0.09 0.36 25 22 23 26 > .98 > .95 > .99 > .90 0/-18 37 -C 0/-18 37 -C < 10 0/-18 40 47 CBT 0.41 0.18 0.35 0.16 0.37 0.16 0.44 0.19 49 48 42 44 52 51 > .98 < 10 0/-18 37 -C < 10 0/-18 37 -C 0.40 26 25 > .97 > .50 47 CBT 3.12 3.19 3.23 < 150 0/-18 0.89 4.12 4.05 3.87 < 10 < 15 < 10 < 15 1.00 3.85 1.00 > .99 > .95 0.89 > .99 > .98 0.95 > .99 > .98 1.15 2.04 2.08 2.12 2.21 2.25 < 10 0/-18 37 -D < 10 0/-18 37 -D > .50 3.85 < 150 0/-18 47 CBT > .97 > .50 1.15 0.97 1.03 1.15 1.00 4.60 2.16 < 150 0/-18 48 CBT ESX See page 2-38 for Dimensions and Wiring Diagrams STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAGE 2-35 PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Lamp Certification Starting Line Catalog NOM Qty. Method Volts Number F8T5 - One Lamp Applications 1 RS 120 CBT113L-120 n • • F8T5 - Two Lamp Applications 2 RS 120 CBT213L-120 n • • F13T5 - One Lamp Applications 1 RS 120 CBT113L-120 n • • F13T5 - Two Lamp Applications 2 SER-RS 120 CBT213L-120 n • • F14T5 - One Lamp Applications 120 • • • 277 B228PUNV-C 120 PRS • 1 277 B228PUNV90-C • 120 ES4528X • • 277 1 RS 120 CBT113L-120 n • • F14T5 - Two Lamp Applications 120 • • • 277 B228PUNV-C 120 • 277 B228PUNV90-C • 120 • 2 SER-PRS 277 B228PUNV95-D • 120 • 277 B228PUNV115-D • 2 SER-RS 120 CBT213L-120 n • • F21T5 - One Lamp Applications 120 • • • 277 B228PUNV-C 120 PRS • • 1 277 B228PUNV90-C 120 • • 277 ES4528X RS 120 CBT213L-120 n • • F21T5 - Two Lamp Applications 120 • • • 277 B228PUNV-C 120 • • 277 B228PUNV90-C 2 SER-PRS 120 • 277 B228PUNV95-D • 120 • 277 B228PUNV115-D • F24T5 - One Lamp Applications 1 RS 120 CBT126L-120 n • • n Add “B” for Bottom Exit or “S” for Side Exit or “BS” for Bottom Exit with 2” O.C. screw studs. T5 • Multiple Lamp Operation • Rapid and Programmed Rapid Starting Options • T5 Ballasts meet ANSI requirement for end-of-lamp life safety shutdown • Super Low Profile Designs • 1-2 Lamp Applications Fluorescent-Electronic T5 TRIAD® T5 ELECTRONIC BALLASTS • Multiple Lamp Operation • Rapid and Programmed Rapid Starting Options • T5 Ballasts meet ANSI requirement for end-of-lamp life safety shutdown • Super Low Profile Designs • 1-2 Lamp Applications Lamp Certification Starting Line Catalog NOM Qty. Method Volts Number F28T5 - One Lamp Applications 120 • • • 277 B228PUNV-C 120 PRS • • 1 277 B228PUNV90-C 120 ES4528X • • 277 1 RS 120 CBT213L-120 n • • F28T5 - Two Lamp Applications 120 • • • 277 B228PUNV-C 120 • • 277 B228PUNV90-C 2 SER-PRS 120 B228PUNV95-D • • 277 120 • 277 B228PUNV115-D • F35T5 - One Lamp Applications 120 PRS • • 1 277 ES4528X n Add “B” for Bottom Exit or “S” for Side Exit or “BS” for Bottom Exit with 2” O.C. screw studs. FOR F28 AND F35T5 LAMPS Line Input Power Ballast Ballast Min. F/C Current Power Factor Factor Efficacy THD Start Wiring (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. 0.28 0.12 0.11 0.25 0.27 0.12 0.45 33 29 30 > .98 > .95 > .99 > .90 34 > .97 30 0.55 0.23 0.48 0.21 0.50 0.21 0.59 0.25 66 64 58 56 58 57 69 68 0.34 0.15 42 > .50 1.00 3.03 0.90 3.10 3.00 1.00 2.94 0.96 3.20 > .99 > .98 > .99 > .98 1.00 0.90 0.95 1.15 1.52 1.56 1.55 1.61 1.64 1.67 1.67 1.69 > .97 1.00 2.38 > .98 > .98 < 10 0/-18 37 -C 0/-18 37 -C < 10 0/-18 < 150 0/-18 40 47 ESX CBT < 10 0/-18 37 -C < 10 0/-18 37 -C < 10 0/-18 37 -D < 10 0/-18 37 -D < 10 0/-18 40 ESX < 10 < 15 See page 2-38 for Dimensions and Wiring Diagrams IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAGE 2-36 PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD T5HO ELECTRONIC BALLASTS ® FOR F24, F39 AND F54 T5HO LAMPS • Multiple Lamp Operation • Programmed Rapid and Instant Starting Models • T5HO Ballasts meet ANSI requirements for end-of-lamp life safety shutdown • Super Low Profile Designs • 1-4 Lamp Applications Ballast Ballast Min. F/C Factor Efficacy THD Start Wiring (BF) Factor (BEF) % Temp Diag. Dim. 1.06 3.79 < 10 0/-18 37 -C 1.00 1.89 1.92 < 10 0/-18 37 -C 1.15 1.95 < 10 0/-18 37 -D 0.95 2.32 2.38 < 10 0/-18 37 -C 1.10 2.34 < 10 0/-18 37 -D 1.00 1.12 1.14 < 10 0/-18 37 -D < 10 < 15 0/-18 42 -E < 10 0/-18 37 -D 1.02 1.02 1.55 1.62 1.65 1.62 1.65 1.59 1.00 1.00 1.00 1.00 1.00 1.00 0.83 0.84 0.83 0.85 0.83 0.85 0.83 0.83 0.86 0.82 0.83 1.05 1.05 0.58 0.59 0.57 0.58 1.00 1.00 0.42 0.43 0.43 0.44 1.00 1.15 1.16 1.02 1.02 < 10 0/-18 37 -D < 10 0/-18 4b -D < 10 0/-18 41 -E < 10 0/-18 37 -D < 10 0/-18 37 -D < 10 < 10 < 15 < 10 < 15 0/-18 4b -D 0/-18 44 -E 0/-18 44 -E < 10 0/-18 44 -E < 10 0/-18 44 -E < 10 0/-18 44 -E < 10 0/-18 44 -E < 10 0/-18 43 ESK See page 2-38 for Dimensions and Wiring Diagrams IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAGE 2-37 PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Lamp Certification Line Input Power Starting Line Catalog Current Power Factor NOM Qty. Method Volts Number (Amps) (Watts) (PF) F24T5HO - One Lamp Applications 120 0.23 > .98 1 PRS B224PUNV-C • • • 28 277 0.10 > .95 F24T5HO - Two Lamp Applications 120 0.45 53 B224PUNV-C • • • > .98 277 0.19 52 2 SER-PRS 120 0.51 > .98 B239PUNV-D • • • 59 277 0.22 > .95 F39T5HO - One Lamp Applications 120 0.34 41 B224PUNV-C • • • > .98 277 0.15 40 1 PRS 120 0.39 > .98 B239PUNV-D • • • 47 277 0.18 > .95 F39T5HO - Two Lamp Applications 120 0.75 89 2 SER-PRS B239PUNV-D • • • > .98 277 0.32 88 F54T5HO - One Lamp Applications 347 0.19 > .98 B254PHRVHB-E • • 66 480 0.15 > .90 120 0.52 63 > .99 B254PUNV-D • • • 1 PRS 277 0.23 62 > .95 120 0.52 63 > .99 B254PUNVHB-D • • • 277 0.23 62 > .95 347 B254P347-D • 0.19 64 > .95 F54T5HO - Two Lamp Applications 347 0.35 120 > .98 B254PHRVHB-E • • 480 0.26 119 > .95 120 1.03 120 > .99 B254PUNV-D • • • 277 0.43 117 > .98 120 1.03 120 > .99 B254PUNVHB-E • • • 2 SER-PRS 277 0.43 117 > .98 347 B254P347-D • 0.35 120 > .98 120 1.01 121 B454PUNV-E • • > .95 277 0.44 116 120 1.01 122 B454PUNVHB-E • • > .95 277 0.44 121 F54T5HO - Three Lamp Applications 120 1.52 181 > .98 B454PUNV-E • • 277 0.66 178 > .95 3 SER-PRS 120 1.52 184 > .98 B454PUNVHB-E • • 277 0.66 182 > .95 F54T5HO - Four Lamp Applications 120 2.01 240 > .98 B454PUNV-E • • 277 0.86 234 > .99 4 SER-PRS 120 1.96 235 > .98 B454PUNVHB-E • • 277 0.84 229 > .99 F80T5HO - One Lamp Applications 120 0.73 87 1 PRS ES4515K • • > .97 277 0.32 86 T5HO T5 TRIAD® T5 & T5HO ELECTRONIC BALLASTS & T5HO Overall Dimensions Draw # L -C CBT -D -E ESK ESX 14.25” 3.86” 16.88” 16.88” 16.65” 14.13” W 1.18” 2.00” 1.18” 1.74” 1.24” 1.24” Mounting Dimensions H M X 1.00” 1.00” 1.00” 1.18” 1.00” 0.73” 13.75” 3.50” 16.20” 16.28” 16.30” 13.78” — — — — — — WIRING DIAGRAMS DIAGRAM 4b Fluorescent-Electronic -C, -D CBT -E, ESK, ESX DIAGRAM 37 T5 ballasts incorporate poke in connectors, for easy installation DIAGRAM 40 DIAGRAM 43 DIAGRAM 41 DIAGRAM 42 For one lamp operation, individually cap yellow and yellow/black leads, insulate to 600V. DIAGRAM 44 DIAGRAM 47 DIAGRAM 48 PAGE 2-38 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® ELECTRONIC BALLASTS FOR (1), (2) AND (3) F30T12, F30T12ES, & (2)F32T12 LAMPS ST -A 9.50” 9.50” W 2.40” 1.70” Mounting Dimensions H M X 1.55” 1.18” 8.89” 8.89” T12 Straight Lamps • 1-3 Lamp Applications Line Input Power Ballast Ballast Min. F/C Current Power Factor Factor Efficacy THD Start Wiring (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. 0.26 0.11 0.33 0.14 30 30 37 37 > .95 > .95 > .95 > .95 0.91 0.91 1.05 1.05 3.03 3.03 2.84 2.84 < 10 < 10 < 10 < 10 50/10 50/10 50/10 50/10 2 2 4 4 ST ST ST ST 0.51 0.50 0.22 59 60 60 > .95 > .95 > .95 0.92 0.92 0.92 1.56 1.53 1.53 < 20 < 10 < 10 50/10 50/10 50/10 4 4 4 ST ST ST 0.75 0.33 90 90 > .98 > .98 0.91 0.91 1.01 1.01 < 10 < 10 50/10 50/10 5 5 ST ST 0.24 0.10 0.30 0.13 27 27 33 33 > .97 > .97 > .95 > .95 0.86 0.86 1.00 1.00 3.19 3.19 3.03 3.03 < 10 < 10 < 10 < 10 60/16 60/16 60/16 60/16 2 2 4 4 ST ST ST ST 0.46 0.20 53 53 > .98 > .98 0.88 0.88 1.66 1.66 < 10 < 10 60/16 60/16 4 4 ST ST 0.64 0.28 76 76 > .98 > .98 0.88 0.88 1.16 1.16 < 10 < 10 60/16 60/16 5 5 ST ST 0.48 56 > .98 0.90 1.61 < 25 50/10 2 -A STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Overall Dimensions Draw # L • Standard & High Performance Models PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start WIRING DIAGRAMS 1.69” 1.69” DIAGRAM 2 ST For One lamp Operation, Individually Cap blue leads, Insulate to 600V DIAGRAM 4 -A DIAGRAM 5 PAGE 2-39 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Lamp Certification Starting Line Catalog NOM Qty. Method Volts Number F30T12 - One Lamp Applications 120 B140R120HP • • 277 B140R277HP • • 1 RS 120 B240R120HP • • • 277 B240R277HP • • F30T12 - Two Lamp Applications 120 B240R120RH • • 2 PAR-RS 120 B240R120HP • • • 277 B240R277HP • • F30T12 - Three Lamp Applications 120 B340R120HP • • 3 PAR-RS 277 B340R277HP • • F30T12ES - One Lamp Applications 120 B140R120HP • • 277 B140R277HP • • 1 RS 120 B240R120HP • • • 277 B240R277HP • • F30T12ES - Two Lamp Applications 120 B240R120HP • • • 2 PAR-RS 277 B240R277HP • • F30T12ES - Three Lamp Applications 120 B340R120HP • • 3 PAR-RS 277 B340R277HP • • F32T12 - Two Lamp Applications 2 SER-RS 120 B234SR120M-A • • F30T12, F30T12ES, F32T12 • Rapid Starting Options F40T12 TRIAD® ELECTRONIC BALLASTS • Standard & High Performance Models & F34T12ES FOR (1) , (2) AND (3) F40T12 AND F34T12ES LAMPS • Rapid Starting Options T12 Straight Lamps • 1-3 Lamp Applications T12 U-Shaped Lamps Fluorescent-Electronic Lamp Certification Line Input Power Starting Line Catalog Current Power Factor NOM Qty. Method Volts Number (Amps) (Watts) (PF) F40T12 - One Lamp Applications 120 B140R120HP • • 0.33 38 > .99 277 B140R277HP • • 0.14 38 > .99 120 B134R120M-A • • 0.36 36 > .90 1 RS 277 B234SR277M-A • • 0.17 42 > .88 120 B240R120RH • • 0.41 46 > .90 120 B240R120HP • • • 0.42 46 > .98 277 B240R277HP • • 0.18 46 > .98 F40T12 - Two Lamp Applications 120 B240R120RH • • 0.62 73 > .98 120 B240R120HP • • • 0.65 75 > .99 2 PAR-RS 277 B240R277HP • • 0.28 74 > .99 120 B340R120HP • • 0.70 84 > .98 277 B340R277HP • • 0.31 84 > .98 2 SER-RS 120 B234SR120M-A • • 0.63 71 > .90 277 B234SR277M-A • • 0.26 70 > .90 F40T12 - Three Lamp Applications 120 B340R120HP • 0.94 113 > .99 3 PAR-RS 277 B340R277HP • • 0.41 113 > .99 F34T12ES - One Lamp Applications 120 B140R120HP • • 0.28 32 > .98 277 B140R277HP • • 0.12 32 > .98 120 B134R120M-A • • 0.30 31 > .90 1 RS 277 B234SR277M-A • • 0.15 25 > .80 120 B240R120RH • • 0.36 39 > .89 120 B240R120HP • • • 0.35 39 > .98 277 B240R277HP • • 0.15 39 > .98 F34T12ES - Two Lamp Applications 120 B240R120RH • • 0.53 62 > .95 2 PAR-RS 120 B240R120HP • • • 0.54 63 > .99 277 B240R277HP • • 0.23 63 > .99 2 SER-RS 120 B234SR120M-A • • 0.49 59 > .90 277 B234SR277M-A • • 0.23 60 > .90 F34T12ES - Three Lamp Applications 120 B340R120HP • • 0.78 93 > .99 3 PAR-RS 277 B340R277HP • • 0.34 93 > .99 Overall Dimensions Draw # L ST -A 9.50” 9.50” W 2.40” 1.70” Mounting Dimensions H M X 1.55” 1.18” 8.89” 8.89” 0.88 0.88 0.86 0.94 1.09 1.02 1.02 2.32 2.32 2.39 2.24 2.37 2.22 2.22 < 10 < 10 < 30 < 30 < 20 < 10 < 10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 2 2 2 4 4 4 4 ST ST -A -A ST ST ST 0.89 0.90 0.90 1.04 1.04 0.90 0.87 1.22 1.20 1.22 1.24 1.24 1.27 1.24 < 20 < 10 < 10 < 10 < 10 < 30 < 30 50/10 50/10 50/10 50/10 50/10 50/10 50/10 4 4 4 5 5 30 4 ST ST ST ST ST -A -A 0.88 0.88 0.78 0.78 < 10 < 10 50/10 50/10 5 5 ST ST 0.86 0.86 0.86 0.94 1.10 0.97 0.97 2.69 2.69 2.77 2.69 2.82 2.49 2.49 < 10 < 10 < 30 < 30 < 20 < 10 < 10 60/16 60/16 60/16 50/10 60/16 60/16 60/16 2 2 2 4 4 4 4 ST ST -A -A ST ST ST 0.89 0.86 0.86 0.86 0.87 1.44 1.37 1.37 1.46 1.45 < 20 < 10 < 10 < 30 < 30 60/16 60/16 60/16 60/16 50/10 4 4 4 30 4 ST ST ST -A -A 0.86 0.86 0.92 0.92 < 10 < 10 60/16 60/16 5 5 ST ST WIRING DIAGRAMS 1.69” 1.69” DIAGRAM 2 ST Ballast Ballast Min. F/C Factor Efficacy THD Start Wiring (BF) Factor (BEF) % Temp Diag. Dim. -A For One Lamp Applications, individually cap blue leads, Insulate fo 600V DIAGRAM 4 DIAGRAM 5 DIAGRAM 30 PAGE 2-40 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® ELECTRONIC BALLASTS • Standard & High Performance Models FOR F48T12, F48T12ES, F60T12, F64T12 & F72T12 LAMPS • Instant Starting Options STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start SL -A ST ST 11.75” 9.50” 9.50” W 3.13” 1.70” 2.40” Mounting Dimensions H M X 1.78” 1.18” 1.55” SL 11.14” 8.89” 8.89” Ballast Ballast Min. F/C Factor Efficacy THD Start Wiring (BF) Factor (BEF) % Temp Diag. Dim. 1.10 2.34 0.92 0.90 0.95 1.21 1.32 1.27 1.28 1.10 2.89 2.82 0.92 0.93 < 10 0/-18 14 SL < 20 < 30 0/-18 50/10 14 14 ST -A < 10 0/-18 14 SL < 10 60/16 14 SL 1.44 1.39 1.41 < 20 60/16 14 ST < 10 60/16 14 SL 1.02 1.10 1.85 1.90 < 20 0/-18 14 ST < 10 0/-18 14 SL 0.90 0.92 1.01 1.00 1.01 < 20 0/-18 14 ST < 10 0/-18 14 SL 1.03 1.10 1.75 1.80 1.15 < 20 0/-18 14 ST < 10 0/-18 14 SL 0.90 0.92 0.95 0.95 0.96 < 20 0/-18 14 ST < 10 0/-18 14 SL 1.04 1.06 1.58 1.56 1.58 < 20 0/-18 14 ST < 10 0/-18 14 SL PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start WIRING DIAGRAMS 2.00” 1.69” 1.69” -A PAGE 2-41 For One Lamp Operation, Insulate one blue lead to 600V DIAGRAM 14 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Overall Dimensions Draw # L SLIMLINE • 1-2 Lamp Applications Lamp Certification Line Input Power Starting Line Catalog Current Power Factor NOM Qty. Method Volts Number (Amps) (Watts) (PF) F48T12 - One Lamp Applications 1 IS 120 0.39 B260IUNVHP • • 47 > .95 277 0.18 F48T12 - Two Lamp Applications 120 B260I120RH • • 0.68 76 > .95 2 PAR-IS 120 B260I120M-A • • 0.62 68 > .90 120 0.61 75 > .98 B260IUNVHP • • 277 0.27 74 > .95 F48T12ES - One Lamp Applications 1 IS 120 0.32 38 > .98 B260IUNVHP • • 277 0.15 39 > .95 F48T12ES - Two Lamp Applications 120 B260I120RH • • 0.60 64 > .95 2 PAR-IS 120 0.57 67 B260IUNVHP • • > .95 277 0.25 66 F60T12 - One Lamp Applications 120 B260I120RH • • 0.46 55 > .95 1 PAR-IS 120 0.49 > .98 B260IUNVHP • • 58 277 0.22 > .95 F60T12 - Two Lamp Applications 120 B260I120RH • • 0.74 89 > .95 2 PAR-IS 120 0.77 92 B260IUNVHP • • > .98 277 0.33 91 F64T12 - One Lamp Applications 120 B260I120RH • • 0.49 59 > .95 1 PAR-IS 120 0.51 61 > .98 B260IUNVHP • • 277 0.35 96 > .95 F64T12 - Two Lamp Applications 120 B260I120RH • • 0.80 95 > .95 2 PAR-IS 120 0.81 97 B260IUNVHP • • > .98 277 0.35 96 F72T12 - One Lamp Applications 120 B260I120RH • • 0.60 66 > .95 1 IS 120 0.55 68 B260IUNVHP • • > .95 277 0.25 67 IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start T12 Slimline Lamps T12 Slimline Lamps SLIMLINE • Standard & High Performance Models TRIAD® ELECTRONIC BALLASTS • Instant Starting Options F72T12(cont.), F84T12, F96T12 & F96T12ES LAMPS • 1-2 Lamp Applications Fluorescent-Electronic Lamp Certification Line Input Power Starting Line Catalog Current Power Factor NOM Qty. Method Volts Number (Amps) (Watts) (PF) F72T12 - Two Lamp Applications 120 B260I120RH • • 0.92 107 > .95 2 PAR-IS 120 B260I120M-A • • 0.90 105 > .95 120 0.90 109 B260IUNVHP • • > .99 277 0.39 107 F84T12 - One Lamp Applications 120 B260I120RH • • 0.63 74 > .95 1 IS 120 0.63 76 B260IUNVHP • • > .98 277 0.28 75 F84T12 - Two Lamp Applications 120 B260I120RH • • 1.02 120 > .95 2 PAR-IS 120 1.03 123 B260IUNVHP • • > .98 277 0.44 120 F96T12 - One Lamp Applications 120 B260I120RH • • 0.73 83 > .95 1 IS 120 0.70 85 B260IUNVHP • • > .98 277 0.31 84 F96T12 - Two Lamp Applications 120 B260I120RH • • 1.16 133 > .95 2 PAR-IS 120 1.16 139 B260IUNVHP • • > .99 277 0.50 137 F96T12ES - One Lamp Applications 120 B260I120RH • • 0.60 66 > .95 1 IS 120 B260I120M-A • • 0.61 66 > .90 120 0.59 72 B260IUNVHP • • > .98 277 0.26 70 F96T12ES - Two Lamp Applications 120 B260I120RH • • 0.93 107 > .95 2 PAR-IS 120 B260I120M-A • • 0.90 105 > .95 120 0.96 112 B260IUNVHP • • > .99 277 0.40 110 STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Overall Dimensions Draw # L SL -A ST 11.75” 9.50” 9.50” ST W 3.13” 1.70” 2.40” Mounting Dimensions H M X 1.78” 1.18” 1.55” 11.14” 8.89” 8.89” SL Ballast Ballast Min. F/C Factor Efficacy THD Start Wiring (BF) Factor (BEF) % Temp Diag. Dim. 0.90 0.90 0.91 0.84 0.86 0.83 0.85 < 20 < 30 0/-18 50/10 14 14 ST -A < 10 0/-18 14 SL 1.05 1.10 1.42 1.45 1.47 < 20 0/-18 14 ST < 10 0/-18 14 -A 0.88 0.88 0.73 0.72 0.73 < 20 0/-18 14 ST < 10 0/-18 14 -A 1.02 1.05 1.23 1.24 1.25 < 20 0/-18 14 ST < 10 0/-18 14 SL 0.86 0.88 0.65 0.63 0.64 < 20 0/-18 14 ST < 10 0/-18 14 SL 1.05 1.09 1.03 1.59 1.65 1.43 1.47 < 20 < 30 60/16 60/16 14 14 ST -A < 10 60/16 14 SL 0.88 0.88 0.88 0.82 0.84 0.79 0.80 < 20 < 30 60/16 60/16 14 14 ST -A < 10 60/16 14 SL PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start WIRING DIAGRAMS 2.00” 1.69” 1.69” -A For One Lamp Operation, Insulate one blue lead to 600V DIAGRAM 14 PAGE 2-42 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) TRIAD® ELECTRONIC BALLASTS FOR T12 HIGH OUTPUT LAMPS • Rapid Starting Options • 2 Lamp Applications ST SL 9.50” 11.75” ST 2.40” 3.13” Mounting Dimensions H M X 1.55” 1.78” 0.89 0.81 0.82 < 10 -20/-29 4 SL 0.89 0.66 0.67 < 10 -20/-29 4 SL 0.95 0.89 0.56 0.55 0.56 < 10 -20/-29 4 SL < 10 -20/-29 4 SL 1.00 0.56 < 25 4 ST 0.89 0.89 0.48 0.48 0.49 < 10 - 20/-29 4 SL < 10 -20/-29 4 SL 0.88 0.88 0.43 0.43 0.44 < 10 - 20/-29 4 SL < 10 -20/-29 4 SL 0.88 0.51 < 10 60/16 4 SL 0.88 0.51 < 10 60/16 4 SL STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start W Ballast Ballast Min. F/C Factor Efficacy THD Start Wiring (BF) Factor (BEF) % Temp Diag. Dim. 8.89” 11.14” 50/10 PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start WIRING DIAGRAMS 1.69” 2.00” SL DIAGRAM 4 PAGE 2-43 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent-Electronic Lamp Certification Line Input Power Starting Line Catalog Current Power Factor NOM Qty. Method Volts Number (Amps) (Watts) (PF) F48T12HO - Two Lamp Applications 120 0.92 110 2 SER-RS B295SRUNVHP • • > .98 277 0.40 109 F60T12HO - Two Lamp Applications 120 1.11 134 2 SER-RS B295SRUNVHP • • > .98 277 0.48 132 F72T12HO - Two Lamp Applications 120 B295SR120HP • • 1.40 169 > .99 2 SER-RS 120 1.40 162 B295SRUNVHPº • • > .99 277 0.61 160 F73T12/BL/HO - Two Lamp Applications 2 SER-RS 120 493B2 • • 1.60 180 > .90 F84T12HO - Two Lamp Applications 120 B295SR120HP • • 1.60 185 > .99 2 SER-RS 120 1.60 176 B295SRUNVHPº • • > .99 277 0.69 173 F96T12HO - Two Lamp Applications 120 B295SR120HP • • 1.77 208 > .99 2 SER-RS 120 1.77 205 B295SRUNVHPº • • > .99 277 0.76 209 F96T12HOES - Two Lamp Applications 120 B295SR120HP • • 1.47 174 > .99 2 SER-RS 120 1.47 174 B295SRUNVHPº • • > .99 277 0.63 171 º Preliminary Data Overall Dimensions Draw # L T12HO • High Performance Models Fluorescent-Electronic T2 • Programmed Rapid Starting Options TRIAD® ELECTRONIC BALLASTS • 1-2 Lamp Applications FOR F6T2, F8T2, F11T2 AND F13T2 LAMPS Lamp Certification Line Input Power Starting Line Catalog Current Power Factor NOM Qty. Method Volts Number (Amps) (Watts) (PF) F6T2 - One And Two Lamp Applications 120 0.12 14 2 SER-PRS ES1786X • • > .97 277 0.07 15 120 0.07 8 1 PRS ES1786X • • > .97 277 0.05 9 F8T2 - One And Two Lamp Applications 120 0.17 20 2 SER-PRS ES1786X • • > .97 277 0.08 21 120 0.10 1 PRS ES1786X • • 11 > .97 277 0.06 F11T2 - One And Two Lamp Applications 120 0.20 2 SER-PRS ES1786X • • 26 > .97 277 0.09 120 0.12 1 PRS ES1786X • • 15 > .97 277 0.07 F13T2 - One And Two Lamp Applications 120 0.27 31 2 SER-PRS ES1786X • • > .97 277 0.13 32 120 0.15 16 1 PRS ES1786X • • > .97 277 0.08 17 ESX 14.13” W 1.24” Mounting Dimensions H M X 0.73” 1.00 1.00 7.14 6.67 12.50 11.11 1.00 < 10 0/-18 37 ESX < 10 0/-18 37 ESX 5.00 4.76 < 10 0/-18 37 ESX 1.00 9.09 < 10 0/-18 37 ESX 1.00 3.85 < 10 0/-18 37 ESX 1.00 6.67 < 10 0/-18 37 ESX 1.00 1.00 3.23 3.13 6.25 5.88 < 10 0/-18 37 ESX < 10 0/-18 37 ESX STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Overall Dimensions Draw # L Ballast Ballast Min. F/C Factor Efficacy THD Start Wiring (BF) Factor (BEF) % Temp Diag. Dim. 13.78” PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start WIRING DIAGRAMS — DIAGRAM 37 ESX PAGE 2-44 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Energy Management System DCL® with DEMANDflex® DEMANDflex® ballasts are high efficiency program start ballasts with the flexibility to be tuned at the circuit level to fixed power levels during installation. They are fully compatible with occupancy sensors and exceed the CEE requirements for high efficiency program start T8 ballasts. DEMANDflex® ballasts having tuning capabilities with ranges from 100% to 50% power levels, making them applicable for a wide range of lighting installations. Installations can start with DEMANDflex® ballasts and after installation, the ballasts can be tuned to maximize energy savings with fixed light levels. No dimming control wires are associated with DEMANDflex® ballasts which makes them easy to install in all existing fluorescent lighting applications. DEMANDflex® ballasts can also be integrated with DCL® controls to be part of the most cost-effective lighting system available. DCL® controls allow for local control with energy management systems and external control via the internet for networked managed systems. DCL® controls allow for integration with utility demand response programs that provide for improved pricing contracts to end-users in exchange for the utility to have the ability to lower lighting power levels during periods of high demand. DCL/DEMANDflex Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group Product Overview DEMANDflex® Ballasts n Power level tuning potential to 50% –Set the circuit power level at installation –Typical 10% to 15% power reduction n Install the same as standard PRS ballasts –No control wires necessary –Standard mounting footprint –Same wiring as program rapid start ballasts n High efficiency program start operation –Exceeds CEE T8 requirements –Compatible with occupancy sensors n NEMA premium –Exceeds CEE T8 requirements –Compatible with occupancy sensors DCL® Controlled Systems n –Avoid high peak charges –Reduce demand costs n Programmable fade rates –Gradual transitions –No disruptions n n DCL/DEMANDflex Reduces lighting power by up to 50% Use existing power connections to communicate to the ballasts –No control wires Implement with various controls and systems –BAS Systems –Photo Cells –Occupancy Sensors –Contact Closure For more information contact Universal or visit www.unvlt.com. PAGE 3-2 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) DEMANDflex® FOR (1), (2), (3) & (4) LAMPS DEMANDflex niversal DCL® Dimming U Programmed Rapid Start 1, 2, 3, & 4 Lamp Applications Visit www.unvlt.com for a comprehensive description of the DCL® system and DEMANDflex® ballasts • • • • T8 Lamp Certification Line Input Power Ballast Ballast Min. F/C Starting Line Catalog Current Power Factor Factor Efficacy THD Start Qty. Method Volts Number c (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp F32T8 - One Lamp Applications Wiring Diag. Dim. • • • • • • • • • • • • • • • • • • • • • • • • 0.24 0.11 0.11 0.05 0.32 0.15 0.14 0.07 0.20 0.09 0.09 0.05 29 14 29 14 38 18 39 19 24 11 24 12 > .95 > .95 > .95 > .90 > .95 > .95 > .95 > .95 > .95 > .95 > .95 > .95 0.88 0.28 0.88 0.28 1.15 0.50 1.15 0.50 0.68 0.18 0.68 0.18 3.01 2.05 3.03 1.96 3.03 2.78 2.95 2.63 2.85 1.64 2.85 1.57 < 10 < 15 < 10 < 15 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 12a 12a 12a 12a 12a 12a 12a 12a 12a 12a 12a 12a -A -A -A -A -A -A -A -A -A -A -A -A B232PUNVDR-A @ 100% 120 B232PUNVDR-A @ 50% B232PUNVDR-A @ 100% 277 B232PUNVDR-A @ 50% B232PUNVDRH-A @ 100% 120 2 PRS B232PUNVDRH-A @ 50% B232PUNVDRH-A @ 100% 277 B232PUNVDRH-A @ 50% B232PUNVDRL-A @ 100% 120 B232PUNVDRL-A @ 50% B232PUNVDRL-A @ 100% 277 B232PUNVDRL-A @ 50% • • • • • • • • • • • • • • • • • • • • • • • • 0.47 0.22 0.20 0.10 0.62 0.30 0.26 0.13 0.40 0.19 0.17 0.09 57 28 56 28 75 37 73 36 47 24 47 24 > .95 > .95 > .95 > .95 > .95 > .90 > .95 > .90 > .95 > .95 > .95 > .95 0.87 0.34 0.87 0.35 1.15 0.50 1.15 0.50 0.71 0.19 0.71 0.19 1.53 1.20 1.56 1.22 1.53 1.35 1.58 1.39 1.51 0.81 1.51 0.81 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 12b 12b 12b 12b 12b 12b 12b 12b 12b 12b 12b 12b -A -A -A -A -A -A -A -A -A -A -A -A B332PUNVDR-A @ 100% 120 B332PUNVDR-A @ 50% B332PUNVDR-A @ 100% 277 B332PUNVDR-A @ 50% B332PUNVDRL-A @ 100% 120 3 PRS B332PUNVDRL-A @ 50% B332PUNVDRL-A @ 100% 277 B332PUNVDRL-A @ 50% B332PUNVDRH-E @ 100% 120 B332PUNVDRH-E @ 50% B332PUNVDRH-E @ 100% 277 B332PUNVDRH-E @ 50% • • • • • • • • • • • • • • • • • • • • • • • • 0.70 0.34 0.30 0.16 0.59 0.29 0.25 0.13 0.95 0.48 0.41 0.21 85 42 83 41 72 36 72 36 115 57 111 55 > .95 > .95 > .95 > .95 > .95 > .95 > .95 > .95 > .95 > .95 > .95 > .95 0.87 0.35 0.87 0.35 0.71 0.22 0.71 0.22 1.15 0.50 1.15 0.50 1.02 0.83 1.05 0.85 0.99 0.61 0.99 0.61 1.00 0.88 1.04 0.91 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 12c 12c 12c 12c 12c 12c 12c 12c 12d 12d 12d 12d -A -A -A -A -A -A -A -A -A -A -A -A B432PUNVDR-E @ 100% 120 B432PUNVDR-E @ 50% B432PUNVDR-E @ 100% 277 4 PRS B432PUNVDR-E @ 50% B432PUNVDRL-E @ 100% 120 B432PUNVDRL-E @ 50% B432PUNVDRL-E @ 100% 277 B432PUNVDRL-E @ 50% • • • • • • • • • • • • • • • • 0.96 0.48 0.41 0.20 0.78 0.37 0.34 0.17 116 58 112 56 93 47 93 47 > .95 > .95 > .95 > .95 > .95 > .95 > .95 > .95 0.88 0.35 0.88 0.35 0.71 0.21 0.71 0.21 0.75 0.60 0.79 0.63 0.76 0.45 0.76 0.45 < 10 < 10 < 10 < 15 < 10 < 15 < 10 < 15 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 12e 12e 12e 12e 12e 12e 12e 12e -A -A -A -A -A -A -A -A F32T8 - Two Lamp Applications F32T8 - Three Lamp Applications F32T8 - Four Lamp Applications See page 3-7 for Dimensions and Wiring Diagrams PAGE 3-3 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) DEMANDflex B232PUNVDR-A @ 100% 120 B232PUNVDR-A @ 50% B232PUNVDR-A @ 100% 277 B232PUNVDR-A @ 50% B232PUNVDRH-A @ 100% 120 1 PRS B232PUNVDRH-A @ 50% B232PUNVDRH-A @ 100% 277 B232PUNVDRH-A @ 50% B232PUNVDRL-A @ 100% 120 B232PUNVDRL-A @ 50% B232PUNVDRL-A @ 100% 277 B232PUNVDRL-A @ 50% DEMANDflex T8 • • • • DEMANDflex® niversal DCL® Dimming U Programmed Rapid Start 1, 2, 3, & 4 Lamp Applications Visit www.unvlt.com for a comprehensive description of the DCL system and DEMANDflex ballasts FOR (1), (2), (3) & (4) LAMPS Lamp Certification Line Input Power Ballast Ballast Min. F/C Starting Line Catalog Current Power Factor Factor Efficacy THD Start Qty. Method Volts Number c (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp F25T8 - One Lamp Applications B232PUNVDR-A @ 100% 120 B232PUNVDR-A @ 50% B232PUNVDR-A @ 100% 277 B232PUNVDR-A @ 50% B232PUNVDRH-A @ 100% 120 1 PRS B232PUNVDRH-A @ 50% B232PUNVDRH-A @ 100% 277 B232PUNVDRH-A @ 50% B232PUNVDRL-A @ 100% 120 B232PUNVDRL-A @ 50% B232PUNVDRL-A @ 100% 277 B232PUNVDRL-A @ 50% • • • • • • • • • • • • • • • • • • • • • • • • 0.19 0.10 0.08 0.05 0.25 0.12 0.11 0.06 0.15 0.08 0.07 0.04 22 12 22 13 30 14 30 15 18 10 18 10 > .95 > .95 > .95 > .90 > .95 > .95 > .95 > .90 > .95 > .95 > .95 > .95 0.87 0.35 0.88 0.35 1.16 0.50 1.16 0.50 0.69 0.18 0.69 0.18 4.00 2.93 3.95 2.82 3.87 3.57 3.81 3.33 3.85 1.84 3.77 1.75 < 10 < 15 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 15 < 10 < 15 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 12a 12a 12a 12a 12a 12a 12a 12a 12a 12a 12a 12a -A -A -A -A -A -A -A -A -A -A -A -A B232PUNVDR-A @ 100% 120 B232PUNVDR-A @ 50% B232PUNVDR-A @ 100% 277 B232PUNVDR-A @ 50% B232PUNVDRH-A @ 100% 120 2 PRS B232PUNVDRH-A @ 50% B232PUNVDRH-A @ 100% 277 B232PUNVDRH-A @ 50% B232PUNVDRL-A @ 100% 120 B232PUNVDRL-A @ 50% B232PUNVDRL-A @ 100% 277 B232PUNVDRL-A @ 50% • • • • • • • • • • • • • • • • • • • • • • • • 0.36 0.19 0.16 0.09 0.46 0.21 0.20 0.10 0.30 0.15 0.13 0.07 44 23 43 23 55 26 55 26 36 18 35 18 > .95 > .95 > .95 > .95 > .95 > .90 > .95 > .90 > .95 > .95 > .95 > .95 0.87 0.35 0.87 0.35 1.15 0.50 1.15 0.50 0.69 0.19 0.69 0.19 2.01 1.56 2.05 1.53 2.09 1.92 2.08 1.92 1.93 1.06 1.95 1.03 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 12b 12b 12b 12b 12b 12b 12b 12b 12b 12b 12b 12b -A -A -A -A -A -A -A -A -A -A -A -A B332PUNVDR-A @ 100% 120 B332PUNVDR-A @ 50% B332PUNVDR-A @ 100% 277 B332PUNVDR-A @ 50% B332PUNVDRL-A @ 100% 120 3 PRS B332PUNVDRL-A @ 50% B332PUNVDRL-A @ 100% 277 B332PUNVDRL-A @ 50% B332PUNVDRH-E @ 100% 120 B332PUNVDRH-E @ 50% B332PUNVDRH-E @ 100% 277 B332PUNVDRH-E @ 50% • • • • • • • • • • • • • • • • • • • • • • • • 0.55 0.27 0.24 0.13 0.47 0.24 0.21 0.11 0.74 0.35 0.33 0.16 66 33 65 32 56 28 55 29 89 42 89 43 > .95 > .95 > .95 > .95 > .95 > .95 > .95 > .90 > .95 > .95 > .95 > .95 0.87 0.35 0.87 0.35 0.71 0.23 0.71 0.23 1.17 0.50 1.17 0.50 1.32 1.06 1.34 1.09 1.27 0.81 1.29 0.80 1.31 1.19 1.31 1.16 < 10 < 10 < 10 < 15 < 10 < 10 < 10 < 10 < 10 < 15 < 10 < 15 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 12c 12c 12c 12c 12c 12c 12c 12c 12d 12d 12d 12d -A -A -A -A -A -A -A -A -A -A -A -A B432PUNVDR-E @ 100% 120 B432PUNVDR-E @ 50% B432PUNVDR-E @ 100% 277 4 PRS B432PUNVDR-E @ 50% B432PUNVDRL-E @ 100% 120 B432PUNVDRL-E @ 50% B432PUNVDRL-E @ 100% 277 B432PUNVDRL-E @ 50% • • • • • • • • • • • • • • • • 0.75 0.37 0.33 0.17 0.61 0.31 0.27 0.15 90 44 89 44 73 37 72 38 > .95 > .95 > .95 > .90 > .95 > .95 > .95 > .90 0.89 0.35 0.89 0.35 0.71 0.21 0.71 0.21 0.99 0.80 1.00 0.80 0.97 0.56 0.98 0.56 < 10 < 15 < 10 < 15 < 10 < 15 < 10 < 15 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 12e 12e 12e 12e 12e 12e 12e 12e -A -A -A -A -A -A -A -A F25T8 - Two Lamp Applications F25T8 - Three Lamp Applications F25T8 - Four Lamp Applications DEMANDflex Wiring Diag. Dim. See page 3-7 for Dimensions and Wiring Diagrams PAGE 3-4 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) DEMANDflex® • • • • FOR (1), (2), (3) & (4) LAMPS DEMANDflex niversal DCL® Dimming U Programmed Rapid Start 1, 2, 3, & 4 Lamp Applications Visit www.unvlt.com for a comprehensive description of the DCL system and DEMANDflex ballasts T8 Lamp Certification Line Input Power Ballast Ballast Min. F/C Starting Line Catalog Current Power Factor Factor Efficacy THD Start Qty. Method Volts Number c (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp F17T8 - One Lamp Applications Wiring Diag. Dim. • • • • • • • • • • • • • • • • • • • • • • • • 0.14 0.08 0.06 0.04 0.18 0.09 0.09 0.05 0.11 0.09 0.05 0.04 16 10 17 10 22 11 22 11 13 10 13 11 > .95 > .95 > .95 > .85 > .95 > .95 > .95 > .90 > .95 > .95 > .95 > .85 0.92 0.27 0.92 0.27 1.15 0.50 1.15 0.50 0.70 0.20 0.70 0.20 5.65 2.81 5.48 2.66 5.23 4.63 5.23 4.55 5.47 1.98 5.22 1.87 < 10 < 15 < 10 < 15 < 10 < 15 < 10 < 15 < 10 < 15 < 10 < 15 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 12a 12a 12a 12a 12a 12a 12a 12a 12a 12a 12a 12a -A -A -A -A -A -A -A -A -A -A -A -A B232PUNVDR-A @ 100% 120 B232PUNVDR-A @ 50% B232PUNVDR-A @ 100% 277 B232PUNVDR-A @ 50% B232PUNVDRH-A @ 100% 120 2 PRS B232PUNVDRH-A @ 50% B232PUNVDRH-A @ 100% 277 B232PUNVDRH-A @ 50% B232PUNVDRL-A @ 100% 120 B232PUNVDRL-A @ 50% B232PUNVDRL-A @ 100% 277 B232PUNVDRL-A @ 50% • • • • • • • • • • • • • • • • • • • • • • • • 0.25 0.13 0.13 0.06 0.32 0.16 0.14 0.07 0.21 0.12 0.09 0.06 30 16 30 16 38 19 39 19 25 15 25 15 > .95 > .95 > .95 > .95 > .95 > .95 > .95 > .90 > .95 > .95 > .95 > .95 0.90 0.27 0.90 0.27 1.16 0.50 1.16 0.50 0.69 0.19 0.69 0.19 3.00 1.72 3.00 1.67 3.05 2.63 2.97 2.63 2.78 1.29 2.76 1.24 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 15 < 10 < 10 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 12b 12b 12b 12b 12b 12b 12b 12b 12b 12b 12b 12b -A -A -A -A -A -A -A -A -A -A -A -A B332PUNVDR-A @ 100% 120 B332PUNVDR-A @ 50% B332PUNVDR-A @ 100% 277 B332PUNVDR-A @ 50% B332PUNVDRL-A @ 100% 120 3 PRS B332PUNVDRL-A @ 50% B332PUNVDRL-A @ 100% 277 B332PUNVDRL-A @ 50% B332PUNVDRH-E @ 100% 120 B332PUNVDRH-E @ 50% B332PUNVDRH-E @ 100% 277 B332PUNVDRH-E @ 50% • • • • • • • • • • • • • • • • • • • • • • • • 0.40 0.20 0.18 0.10 0.33 0.18 0.15 0.09 0.54 0.25 0.24 0.12 48 24 48 24 40 22 40 23 65 32 65 32 > .95 > .95 > .95 > .90 > .95 > .95 > .95 > .85 > .95 > .95 > .95 > .90 0.89 0.36 0.89 0.36 0.73 0.23 0.73 0.23 1.19 0.51 1.19 0.51 1.86 1.51 1.86 1.51 1.83 1.05 1.83 1.02 1.83 1.59 1.84 1.59 < 10 < 10 < 10 < 15 < 10 < 10 < 10 < 15 < 10 < 15 < 10 < 15 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 12c 12c 12c 12c 12c 12c 12c 12c 12d 12d 12d 12d -A -A -A -A -A -A -A -A -A -A -A -A B432PUNVDR-E @ 100% 120 B432PUNVDR-E @ 50% B432PUNVDR-E @ 100% 277 4 PRS B432PUNVDR-E @ 50% B432PUNVDRL-E @ 100% 120 B432PUNVDRL-E @ 50% B432PUNVDRL-E @ 100% 277 B432PUNVDRL-E @ 50% • • • • • • • • • • • • • • • • 0.53 0.27 0.24 0.13 0.43 0.26 0.20 0.12 64 32 63 32 52 31 52 31 > .95 > .95 > .95 > .90 > .95 > .95 > .95 > .90 0.91 0.35 0.91 0.35 0.73 0.21 0.73 0.21 1.42 1.09 1.44 1.09 1.41 0.69 1.41 0.67 < 10 < 15 < 10 < 15 < 10 < 15 < 10 < 15 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 12e 12e 12e 12e 12e 12e 12e 12e -A -A -A -A -A -A -A -A F17T8 - Two Lamp Applications F17T8 - Three Lamp Applications F17T8 - Four Lamp Applications See page 3-7 for Dimensions and Wiring Diagrams FOR MORE INFORMATION CALL PAGE 3-5 1-800-BALLAST (225-5278) DEMANDflex B232PUNVDR-A @ 100% 120 B232PUNVDR-A @ 50% B232PUNVDR-A @ 100% 277 B232PUNVDR-A @ 50% B232PUNVDRH-A @ 100% 120 1 PRS B232PUNVDRH-A @ 50% B232PUNVDRH-A @ 100% 277 B232PUNVDRH-A @ 50% B232PUNVDRL-A @ 100% 120 B232PUNVDRL-A @ 50% B232PUNVDRL-A @ 100% 277 B232PUNVDRL-A @ 50% DEMANDflex • • • • • T5, T5HO & TT5 niversal DCL® Dimming U Programmed Rapid Start 2 Lamp Applications for T5 & T5HO 1 & 2 Lamp Applications for TT5 Visit www.unvlt.com for a comprehensive description of the DCL system and DEMANDflex ballasts DEMANDflex® FOR (2) T5, (2) T5HO and FOR (1) & (2) TT5 LAMPS Lamp Certification Line Input Power Ballast Ballast Min. F/C Starting Line Catalog Current Power Factor Factor Efficacy THD Start Qty. Method Volts Number c (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp F28T5 - Two Lamp Applications B228PUNVDRH-D @ 100% 120 2 PRS B228PUNVDRH-D @ 50% B228PUNVDRH-D @ 100% 277 B228PUNVDRH-D @ 50% • • • • • • • • 0.60 0.30 0.25 0.13 72 36 70 35 > .95 > .95 > .95 > .95 1.15 0.51 1.15 0.50 1.60 1.42 1.64 1.43 < 10 < 10 < 10 < 10 50/10 50/10 50/10 50/10 12f 12f 12f 12f -A -A -A -A B228PUNVDRH-D @ 100% 120 2 PRS B228PUNVDRH-D @ 50% B228PUNVDRH-D @ 100% 277 B228PUNVDRH-D @ 50% • • • • • • • • 0.75 0.38 0.31 0.17 90 45 87 44 > .95 > .95 > .95 > .95 1.13 0.51 1.13 0.51 1.26 1.13 1.30 1.16 < 10 < 10 < 10 < 10 50/10 50/10 50/10 50/10 12f 12f 12f 12f -A -A -A -A B228PUNVDRH-D 120 2 PRS B228PUNVDRH-D B228PUNVDRH-D 277 B228PUNVDRH-D @ 100% @ 50% @ 100% @ 50% • • • • • • • • 0.47 0.23 0.20 0.11 56 28 55 28 > .95 > .95 > .95 > .90 1.16 0.51 1.16 0.51 2.07 1.82 2.11 1.82 < 10 < 10 < 10 < 10 50/10 50/10 50/10 50/10 12f 12f 12f 12f -A -A -A -A B228PUNVDRH-D 120 2 PRS B228PUNVDRH-D B228PUNVDRH-D 277 B228PUNVDRH-D @ 100% @ 50% @ 100% @ 50% • • • • • • • • 0.34 0.16 0.15 0.08 40 19 40 20 > .95 > .95 > .95 > .85 1.17 0.52 1.17 0.52 2.93 2.74 2.93 2.60 < 10 < 10 < 10 < 10 50/10 50/10 50/10 50/10 12f 12f 12f 12f -A -A -A -A B254PUNVDR-D @ 100% 120 2 PRS B254PUNVDR-D @ 50% B254PUNVDR-D @ 100% 277 B254PUNVDR-D @ 50% • • • • • • • • 1.00 0.50 0.43 0.22 120 60 120 60 > .95 > .95 > .95 > .90 1.00 0.45 1.00 0.45 0.83 0.75 0.83 0.75 < 10 < 10 < 10 < 10 0/-18 0/-18 0/-18 0/-18 12f 12f 12f 12f -A -A -A -A B254PUNVDR-D @ 100% 120 2 PRS B254PUNVDR-D @ 50% B254PUNVDR-D @ 100% 277 B254PUNVDR-D @ 50% • • • • • • • • 0.90 0.41 0.39 0.19 108 50 106 50 > .95 > .95 > .95 > .95 1.06 0.57 1.06 0.57 0.98 1.14 1.00 1.14 < 10 < 10 < 10 < 10 0/-18 0/-18 0/-18 0/-18 12f 12f 12f 12f -A -A -A -A B254PUNVDR-D 120 2 PRS B254PUNVDR-D B254PUNVDR-D 277 B254PUNVDR-D @ 100% @ 50% @ 100% @ 50% • • • • • • • • 0.97 0.47 0.42 0.21 115 57 113 57 > .95 > .95 > .95 > .95 1.10 0.63 1.11 0.63 0.96 1.11 0.98 1.11 < 10 < 10 < 10 < 10 0/-18 0/-18 0/-18 0/-18 12f 12f 12f 12f -A -A -A -A B254PUNVDR-D 120 2 PRS B254PUNVDR-D B254PUNVDR-D 277 B254PUNVDR-D @ 100% @ 50% @ 100% @ 50% • • • • • • • • 0.88 0.41 0.38 0.19 106 49 104 48 > .95 > .95 > .95 > .95 1.04 0.56 1.04 0.56 0.98 1.14 1.00 1.17 < 10 < 10 < 10 < 10 0/-18 0/-18 0/-18 0/-18 12f 12f 12f 12f -A -A -A -A C240PUNVDR-A 120 2 PRS C240PUNVDR-A C240PUNVDR-A 277 C240PUNVDR-A @ 100% @ 50% @ 100% @ 50% • • • • • • • • 0.59 0.30 0.25 0.13 69 35 68 34 > .95 > .90 > .95 > .90 0.88 0.40 0.88 0.40 1.28 1.14 1.29 1.18 < 10 < 10 < 10 < 10 32/0 32/0 32/0 32/0 12g 12g 12g 12g -A -A -A -A C240PUNVDR-A 120 1 PRS C240PUNVDR-A C240PUNVDR-A 277 C240PUNVDR-A @ 100% @ 50% @ 100% @ 50% • • • • • • • • 0.29 0.16 0.13 0.08 34 18 36 20 > .95 > .90 > .95 > .90 0.88 0.40 0.88 0.40 2.59 2.22 2.44 2.00 < 10 < 10 < 10 < 10 32/0 32/0 32/0 32/0 12h 12h 12h 12h -A -A -A -A 120 C240PUNVDR-A @ 100% 277 C240PUNVDR-A @ 100% • • • • 0.52 0.22 62 62 > .95 > .95 0.86 0.87 1.39 1.40 < 10 < 10 32/0 32/0 12g 12g -A -A 120 C240PUNVDR-A @ 100% 277 C240PUNVDR-A @ 100% • • • • 0.25 0.12 28 33 > .95 > .95 0.87 0.87 3.11 2.64 < 10 < 10 32/0 32/0 12h 12h -A -A F35T5 - Two Lamp Applications F21T5 - Two Lamp Applications F14T5 - Two Lamp Applications F54T5HO - Two Lamp Applications FT55W/2G11 - Two Lamp Applications FT50W/2G11 - Two Lamp Applications FC12T5-55W - Two Lamp Applications FT40W/2G11 - Two Lamp Applications DEMANDflex Wiring Diag. Dim. FT40W/2G11 - One Lamp Applications FT40W/2G11/ES - Two Lamp Applications 2 PRS 1 PRS FT40W/2G11/ES - One Lamp Applications See page 3-7 for Dimensions and Wiring Diagrams PAGE 3-6 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) DEMANDflex T8 DEMANDflex® WIRING DIAGRAMS Wiring Diagram 12a Wiring Diagram 12e Wiring Diagram 12b Wiring Diagram 12f Wiring Diagram 12c Wiring Diagram 12g Wiring Diagram 12d Wiring Diagram 12h DEMANDflex FOR MORE INFORMATION CALL PAGE 3-7 1-800-BALLAST (225-5278) DCL Controls DCL CONTROLS LP12DCLUNV-xx MODEL DESCription LP12DCLUNV-xx SC20DCLUNV RSMDCL51 WTPDCL51 WPS5527K Circuit Control Panel Single Circuit Controller Contact Interface Controller Time/Photo Controller Photo Sensor for WTPDCL Dimensions Length 32” Width 20” Depth 4.3” Mounting 24” 16” The same cabinet size is used for the four different panels. the quantity of individual controllers installed is determined by the model number. xx = number of circuits (03-12) SC20DCLUNV Mounting pattern Dimensions Length 9.66” Width 3.98” Depth 3.21” Circuit control panels are used to send commands down the lighting circuit to the DemandFlex ballasts. The LP12DCLUNV-xx panels are available with 3 to 12 integral circuit control modules. If more than 12 circuits are being controlled, additional panels can be used. The SC20DCLUNV is used when there are a small number of circuits or space limitations prevent the use of an LP12DCLUNV panel. One RSMDCL51 or WTPDCL51 can control up to 63 circuits. If more than 63 circuits are to be controlled, an RSMDCL can be connected in parallel with either controller for another 63 circuits. Stand Alone Time Clock/Photo Cell DCL Controls Contact Closure Interface Control The WTPDCL51 controller provides time of day scheduling and can also be connected to the WPS5527K Photo Cell for daylight harvesting. Manual override switches are also available. The RSMDCL51 controller integrates with external relays or switches to translate commands to the DCL system. This controller can be used to interface with building automation systems, PLC’s, or switches. These systems may also incorporate photo cells for dayllight harvesting. FOR MORE INFORMATION CALL PAGE 3-8 1-800-BALLAST (225-5278) Controllable Lighting Fluorescent Energy Management / Dimming Ballasts and Controls The effective dimming of fluorescent lights delivers a wide range of benefits: greater control of workspace lighting, ability to create a mood, energy savings, and more. Universal Lighting Technologies (“Universal”) line of electronic dimming ballasts and controls lets you accomplish these goals with a variety of products to suit your dimming needs. From light level switching and analog dimming to digital dimming and controls, Universal has the products and technologies to meet today’s dimming requirements for energy savings and controllable lighting. Fluorescent Dimming Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group Product Overview Universal offers three different families of dimming products that can be used for today’s dimming requirements for architectural lighting control and energy management applications: Ballastar: Light Level Switching SuperDim: Analog (0 to 10 volt) dimming DaliPro: Digital Dimming with the DALI protocol Ballastar® Light Level Switching (S30 & S50) Our Ballastar® line offers two options of light level switching (either 100/50% or 100/60/30%). That makes Ballastar® a cost-effective solution for both new construction and retrofits. Universal Ballastar® ballasts are designed to ensure optimum lamp performance. Their Lamp Current Crest Factors are well below the maximum 1.7 ANSI standard — and they start the lamps according to ANSI recommendations at all dimming levels. Both of these important design parameters ensure optimum lamp performance. In addition, Ballastar® ballasts actually increase cathode heating when dimming to maintain the cathode’s proper temperature, which enhances lamp life and performance stability. Fluorescent Dimming • 1, 2, & 3 lamp models for 120 & 277 volt • Switches to preset light levels, keeping all lamps illuminated • Eliminates the dark spots associated with inboard/outboard configurations • Connects with two line voltage power leads — Wires the same as an inboard/outboard fixture — No special controls required; uses two wall switches • Meets all ASHRAE 90.1 and California Title 24 requirements for lighting control • THD <10% • Lower installed costs; less wiring and equipment required Ballastar® Light Level Switching for ultimate control. PAGE 3-10 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Product Overview SuperDim® Analog Dimming Ballasts Universal Lighting’s new SuperDim® analog dimming ballasts are the most cost-effective choice for large scale dimming applications. SuperDim® ballasts are designed for T8 and T5 linear fluorescent lamps and T4 4-pin quad and triple compact fluorescent lamps. SuperDim® ballasts are compatible with a wide range of 0 – 10 volt controls and can be connected to photocells for daylight harvesting. The resulting energy savings makes it easy to adhere to even the strictest energy requirements, including California Title 24 and ASHRAE 90.1. These versatile ballasts offer programmed rapid start technology for longer lamp life. They also incorporate end-of-lamp-life shutdown circuits, low profile designs and < 10% THD at full bright. Features and Benefits • Ideal for T8 and T5 linear fluorescent lamps and T4 4-pin quad and triple compact fluorescent lamps • Compatible with most 0 – 10 volt manufactured controls • Daylight harvesting options with photocells for maximum energy savings • Programmed rapid start technology maximizes lamp life • Low profile design for fixture design flexibility • End-of-lamp-life shutdown circuitry ensures safe operation • < 10% THD at full bright • Universal input voltage (120–277 volts) for installation flexibility Fluorescent Dimming PAGE 3-11 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent Dimming Notes PAGE 3-12 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Product Overview DaliPro Digital Dimming Ballasts for DALI New DaliPro™ ballasts from Universal Lighting let you take full advantage of the Digital Addressable Lighting Interface (DALI) standard...and that means greater flexibility, greater savings. The DALI Advantage The DALI protocol uses a 2-wire control loop to communicate with up to 64 ballasts. Broadcast, group and individual addressing is used to control light levels, recall scenes and poll ballast status. Many DALI-compatible controls are now available from established manufacturers; and new varieties are being developed daily. DaliPro Features and Benefits • Available for T8, T5, T5HO and compact fluorescent lamps • Provides dimming down to 1% for linear lamps and 3% for compact fluorescent lamps • Lets you adapt instantly to additions or changes in lighting design without ballast or fixture rewiring • Offers status/performance data, including lamp status and system faults • Low profile designs for easy installation in a wide variety of fixtures • Universal input voltage (120– 277 volts) —Installer-friendly; ensures you have the right ballast every time —Reduces inventory costs and requirements • End-of-Lamp Life Shutdown with auto reset circuitry for safe operation • Programmed Rapid Start for long lamp life Fluorescent Dimming PAGE 3-13 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Application And Operating Information Dimming ballasts follow the same guidelines as electronic ballasts in regard to the application and operating information. In addition to the section for electronic ballasts, the following applies specifically to dimming electronic ballasts. SAFETY Analog dimming ballasts are controlled by using a low voltage 10-0vDC control circuit. Care should be taken to insure that the line voltage (AC) wires are not connected to the low voltage DC wires. SuperDim® Electronic dimming ballasts have a protection circuit that will sense if the ballast has been connected in this manner and not harm the ballast or the installer. If connected in this mode, the lamps will dim to the 30% level. New Lamp Installation When new lamps are installed, they must operate at a full bright level for a minimum of 100 hours prior to dimming. Failure to do this will effect lamp life and cause the lamps to not dim properly. Consult your lamp manufacturer for further lamp information. Light Level Switching Installation Note The two power leads for the light level switching ballasts must be connected to the same power circuit. The leads should connect to separate switches or relays for control of the light level switching operation. Connection of the input leads to separate power circuits can damage the ballasts. Note: Do not connect any other ballast to the load side of the switches controlling the switched dimming ballast. Compatible Dimming Controls For a listing of compatible controls for universal analog ballasts, please consult catalog page 3-7, or call 1-800-BALLAST or check out the Dimming and Controls section of our home page at www.unvlt.com. Fusing Fluorescent Dimming Class P ballasts do not require fusing. Fusing can be used when a single circuit has a large number of fixtures/ballasts. For a comprehensive list of appropriate fuses, contact our Technical Engineering Services (TES) Department at 1-800-BALLAST. Detailed Operating Instructions For additional information on all of Universal’s dimming products, consult our website at www.unvlt.com. Application notes, dimming brochures and online training is available PAGE 3-14 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Controls For Analog Dimming Ballasts Manual Controls: Wall Stations & Hand-Held Remotes Manufacturer Website Architectural Lighting Management www.almsys.com Douglas Lighting Controls, Inc. www.douglaslightingcontrols.com Electronics Diversified, Inc. www.edionline.com Genlyte Controls www.lolcontrols.com HUNT Dimming www.huntdimming.com Lehigh Electric Products Co. www.lehighdim.com Leviton www.leviton.com Lutron www.lutron.com/universal NexLight www.nexlight.com PLC-Multipoint www.plcmultipoint.com Sensor Switch, Inc. www.sensorswitch.com The Watt Stopper, Inc. www.wattstopper.com Telephone (888) 446-9137 (604) 873-2797 (800) 547-2690 (800) 526-2731 (970) 484-9048 (610) 395-3386 (800) 323-8902 (888) LUTRON1 - Sales (800) 523-9466 - Technical Support (218) 828-3700 (425) 353-7552 (800) 727-7483 (800) 879-8585 Manufacturer Website Electronics Diversified, Inc. www.edionline.com Lehigh Electric Products Co. www.lehighdim.com Leviton www.leviton.com Lutron www.lutron.com/universal Marlin Controls, Inc. www.marlincontrols.com NexLight www.nexlight.com Novitas www.novitas.com The Watt Stopper, Inc. www.wattstopper.com Telephone (800) 547-2690 (610) 395-3386 (800) 323-8902 (888) LUTRON1 - Sales (800) 523-9466 - Technical Support (800) 788-5750 (218) 828-3700 (310) 218-5360 (800) 879-8585 Occupancy Sensors & Controls Photodetectors & Daylight Controls Manufacturer Website Douglas Lighting Controls, Inc. www.douglaslightingcontrols.com Electronics Diversified, Inc. www.edionline.com Hubbell Building Automation, Inc. www.hubbell-automation.com Lehigh Electric Products Co. www.lehighdim.com Leviton www.leviton.com Lutron www.lutron.com/universal Marlin Controls, Inc. www.marlincontrols.com NexLight www.nexlight.com Novitas www.novitas.com PLC-Multipoint www.plcmultipoint.com Sensor Switch, Inc. www.sensorswitch.com The Watt Stopper, Inc. www.wattstopper.com Telephone (604) 873-2797 (800) 547-2690 (888) 698-3242 (610) 395-3386 (800) 323-8902 (888) LUTRON1 - Sales (800) 523-9466 - Technical Support (800) 788-5750 (218) 828-3700 (310) 218-5360 (425) 353-7552 (800) 727-7483 (800) 879-8585 Systems: Control Panels, Building Management Systems, etc. Telephone (888) 446-9137 (604) 873-2797 (800) 547-2690 (800) 526-2731 (970) 484-9048 (610) 395-3386 (800) 323-8902 (888) LUTRON1 - Sales (800) 523-9466 - Technical Support (800) 788-5750 (218) 828-3700 (425) 353-7552 (800) 227-5154 (800) 879-8585 Universal Lighting Technologies Analog Dimming Ballasts The information listed above is provided by Universal Lighting Technologies to facilitate development of dimming systems. All information has been provided by the controls manufacturers, and Universal Lighting Technologies makes no guarantee regarding its accuracy. The reader is advised to contact these, and other manufacturers of analog dimming systems, to obtain application advice, to determine availability of the controls listed above, and to learn about other controls that may be offered. Data is subject to change without notice. PAGE 3-15 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent Dimming Manufacturer Website Architectural Lighting Management www.almsys.com Douglas Lighting Controls, Inc. www.douglaslightingcontrols.com Electronics Diversified, Inc. www.edionline.com Genlyte Controls www.lolcontrols.com HUNT Dimming www.huntdimming.com Lehigh Electric Products Co. www.lehighdim.com Leviton www.leviton.com Lutron www.lutron.com/universal Marlin Controls, Inc. www.marlincontrols.com NexLight www.nexlight.com PLC-Multipoint www.plcmultipoint.com Touch-Plate Lighting Controls www.touchplate.com The Watt Stopper, Inc. www.wattstopper.com DaliPro® DIMMING BALLASTS Fluorescent Dimming DaliPro® Lamp Starting Line Catalog Qty. Method Volts Number F32T8 120 1 PRS B132PUNVDV1l 277 120 2 PRS B232PUNVDV1l 277 F14T5 120 1 PRS B114PUNVDV1 277 120 2 PRS B214PUNVDV1 277 F28T5 120 1 PRS B128PUNVDV1 277 120 2 PRS B228PUNVDV1 277 F54T5HO 120 1 PRS B154PUNVDV1 277 120 2 PRS B254PUNVDV1 277 CFQ18W/Gx24q 120 1 PRS C118PUNVDV3w£ 277 120 2 PRS C218PUNVDV3wn 277 CFQ26W/Gx24q 120 1 PRS C126PUNVDV3w´ 277 120 2 PRS C226PUNVDV3wp 277 CFTR32W/Gx24q 120 1 PRS C132PUNVDV3w 277 120 2 PRS C232PUNVDV3w 277 CFM42W/Gx24q 120 1 PRS C142PUNVDV3w 277 120 2 PRS C242PUNVDV3w 277 FT40W/2G11 120 1 PRS C140PUNVDV3w 277 120 2 PRS C240PUNVDV3w 277 Line Current (Amps) 0.31 0.13 0.61 0.26 l Minimum Dimming Temperature is 50°F / 10°C £Also operates (1) CFTR18W/Gx24q n Also operates (2) CFTR18W/Gx24q ´Also operates (1) CFTR26W/Gx24q pAlso operates (2) CFTR26W/Gx24q Power Factor (PF) Ballast Factor (BF) Ballast Efficacy THD Factor (BEF) % 37 > .98 1.00 36 73 > .98 1.00 70 2.70 2.78 1.37 1.43 18 > .98 1.00 18 > .98 Min. F/C Start Wiring Temp Diag. Dim. <10 0/-18 7 DP1 <10 0/-18 8 DP1 5.56 <10 50/10 7 DP1 1.00 2.86 <10 50/10 8 DP1 0.27 0.11 0.55 0.23 32 > .98 1.00 31 66 > .98 1.00 63 3.13 3.23 1.52 1.59 <10 50/10 7 DP1 <10 50/10 8 DP1 0.52 0.22 1.05 0.44 62 > .98 1.00 60 126 > .98 1.00 121 1.61 1.67 0.79 0.83 <10 50/10 7 DP1 <10 50/10 8 DP1 0.19 0.10 0.34 0.16 21 > .95 1.00 20 39 > .95 1.00 38 4.76 5.00 2.56 2.63 <10 0/-18 9 DP2 <10 0/-18 10 DP2 0.28 0.12 0.50 0.23 28 > .95 1.00 27 54 > .95 1.00 53 3.57 3.70 1.85 1.89 <10 0/-18 9 DP2 <10 0/-18 10 DP2 0.34 0.15 0.58 0.26 38 > .95 1.00 37 71 > .95 1.00 70 2.63 2.70 1.41 1.43 <10 0/-18 9 DP2 <10 0/-18 10 DP2 0.43 0.19 0.82 0.36 47 > .95 1.00 45 92 > .95 1.00 91 2.13 2.22 1.09 1.10 <10 0/-18 9 DP2 <10 0/-18 10 DP2 0.37 0.16 0.83 0.37 45 > .95 1.00 44 97 > .95 1.00 94 2.22 2.27 1.03 1.06 <10 0/-18 9 DP1 <10 0/-18 10 DP1 0.15 0.07 0.28 0.13 All models are cULus Listed w Minimum Dimming Temperature is 32°F / 0°C Input Power (Watts) See page 3-20for Dimensions and Wiring Diagrams STARTING METHOD LEGEND IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start PAGE 3-16 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) SuperDim ® DIMMING BALLASTS SuperDim ® Please visit www.unvlt.com for the most up to date status and recent changes to the SuperDim product family. Lamp Starting Qty. Method F17T8 1 PRS 1 PRS 2 PRS 2 PRS Power Factor (PF) 120 ES5833B ES-1-T8-17-UNV-B-DIM-10 • • 277 120 ES5818K ES-1-T8-17-UNV-K-DIM-10 • • 277 120 ES5834B ES-2-T8-17-UNV-B-DIM-10 • • 277 120 ES5817K ES-2-T8-17-UNV-K-DIM-10 • • 277 0.17 20 0.08 21 0.17 20 0.08 21 0.29 35 0.13 0.29 35 0.13 > .99 0.87 > .95 > .99 0.87 > .95 > .99 0.87 > .98 > .99 0.87 > .98 4.35 4.20 4.35 4.20 2.51 2.47 2.51 2.47 120 ES5821B ES-1-T8-32/25-UNV-B-DIM-10 • • 277 120 ES5835K ES-1-T8-32/25-UNV-K-DIM-10 • • 277 120 ES5822B ES-2-T8-32/25-UNV-B-DIM-10 • • 277 120 ES5836K ES-2-T8-32/25-UNV-K-DIM-10 • • 277 0.21 26 0.10 0.21 26 0.10 0.41 48 0.18 0.41 48 0.18 > .99 0.87 > .90 > .99 0.87 > .90 > .99 0.87 > .95 > .99 0.87 > .95 3.41 3.36 3.40 3.31 1.80 1.82 1.80 1.82 120 ES5821B ES-1-T8-32/25-UNV-B-DIM-10 • • 277 120 ES5835K ES-1-T8-32/25-UNV-K-DIM-10 • • 277 120 ES5822B ES-2-T8-32/25-UNV-B-DIM-10 • • 277 120 ES5836K ES-2-T8-32/25-UNV-K-DIM-10 • • 277 0.29 34 0.13 0.27 33 0.13 34 0.56 65 0.23 64 0.56 65 0.23 64 > .99 0.87 > .95 > .99 0.87 > .95 > .99 0.87 > .98 > .99 0.87 > .95 2.60 2.57 2.63 2.60 1.33 1.37 1.33 1.37 120 ES5849K ES-1-T5-14-UNV-K-DIM-10 • • 277 120 ES5851K ES-2-T5-14-UNV-K-DIM-10 • • 277 0.16 20 0.07 0.28 34 0.13 > .99 1.00 > .98 > .99 1.00 > .95 120 ES5839K ES-1-T5-21-UNV-K-DIM-10 • • 277 120 ES5861K ES-2-T5-21-UNV-K-DIM-10 • • 277 0.23 28 0.16 0.40 48 0.17 > .99 > .98 > .99 > .98 120 ES5846K ES-1-T5-28-UNV-K-DIM-10 • • 277 120 ES5847K ES-2-T5-28-UNV-K-DIM-10 • • 277 F35T5 120 1 PRS ES5853K ES-1-T5-35-UNV-K-DIM-10 • • 277 CFQ/H13W 120 2 PRS ES5011GT/HT£v ES-2/1-CFQ-13-UNV-GT/HT-DIM-10 • • 277 CFQ/H18W 120 2 PRS ES5012GT/HT nv ES-2/1-CFQ-18-UNV-GT/HT-DIM-10 • • 277 CFQ/H26W 120 2 PRS ES5013GT/HT´v ES-2/1-CFQ-26-UNV-GT/HT-DIM-10 • • 277 CFH42W 120 1 PRS ES5010GT/HT pv ES-1-CFH-42/36/26-UNV-GT/HT-DIM-10 • • 277 FT40W/2G11 120 1 PRS ES5006BMµ ES-1-CFT-40-UNV-BM-DIM-10 • • 277 120 2 PRS ES5007BMTµ ES-2-CFT-40-UNV-BMT-DIM-10 • • 277 £Also operates (1) CFQ/H13W n Also operates (1) CFQ/H18W ´Also operates (1) CFQ/H26W pAlso operates (1) CFH32W and (1) FQ/H26W HT suffix—Lead entry is bottom feed GT suffix—Lead entry is end feed µIncorporates lead wires v PAGE 3-17 Ballast Ballast Factor Efficacy THD (BF) Factor (BEF) % Min. F/C Start Wiring Temp Diag. Dim. <10 32/0 1 ESB <10 32/0 1 ESK <10 32/0 2 ESB <10 32/0 2 ESK <10 32/0 1 ESB <10 32/0 1 ESK <10 32/0 1 ESB <10 32/0 1 ESK <10 32/0 1 ESB <10 32/0 1 ESK <10 32/0 2 ESB <10 32/0 2 ESK 5.13 4.95 <10 32/0 1 ESK 2.94 <10 32/0 2 ESK 1.00 3.64 <10 32/0 1 ESK 1.00 2.08 <10 32/0 2 ESK 0.30 37 0.14 0.56 67 0.25 > .99 1.00 > .95 > .99 1.00 > .98 2.67 2.71 1.49 1.50 <10 32/0 1 ESK <10 32/0 2 ESK 0.34 0.15 40 41 > .99 1.00 > .98 2.50 2.44 <10 32/0 1 ESK 0.25 0.11 30 29 > .99 1.00 > .95 3.38 3.41 <10 32/0 3 GT/HT 0.31 38 0.14 > .99 > .95 1.00 2.66 <10 32/0 3 GT/HT 0.46 0.19 54 52 > .99 1.00 > .95 1.85 1.94 <10 32/0 3 GT/HT 0.34 46 0.15 > .99 1.00 > .95 2.41 2.20 <10 32/0 4 GT/HT 44 > .99 1.09 43 > .98 88 > .99 1.09 87 2.48 2.53 1.24 1.25 <10 32/0 5 ESBM <10 32/0 6 ESBMT 0.35 0.16 0.73 0.31 STARTING METHOD LEGEND PRS = Programmed Rapid Start See page 3-20 for Dimensions and Wiring Diagrams FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent Dimming F25T8 1 PRS 1 PRS 2 PRS 2 PRS F32T8 1 PRS 1 PRS 2 PRS 2 PRS F14T5 1 PRS 2 PRS F21T5 1 PRS 2 PRS F28T5 1 PRS 2 PRS Certification Line Input Line Catalog Current Power Volts Number Description (Amps) (Watts) BALLASTAR 0-10V DIMMING T8 Straight Lamps • Rapid Start • 1, 2, 3 & 4 Lamp Applications FOR (1), (2), (3) & (4) T8 LAMPS Please visit www.unvlt.com for the most up to date status and recent changes to the Ballastar 0-10V product family. T12 U-Shaped Lamps Fluorescent Dimming BALLASTAR ® 0-10 VOLT DIMMING BALLASTS • Analog Dimming Lamp Starting Line Catalog Qty. Method Volts Number F25T8 - One Lamp Applications B132R120V5 @ 100% 120 B132R120V5 @ 5% B132R277V5 @ 100% 1 RS 277 B132R277V5 @ 5% B132R347V5 @ 100% 347 B132R347V5 @ 5% F25T8 - Two Lamp Applications B232SR347V5 @ 100% 2 RS 347 B232SR347V5 @ 5% F25T8 - Four Lamp Applications B432P277V5-E @ 100% 4 PAR-PRS 277 B432P277V5-E @ 5% F32T8 - One Lamp Applications B132R120V5 @ 100% 120 B132R120V5 @ 5% B132R277V5 @ 100% 1 RS 277 B132R277V5 @ 5% B132R347V5 @ 100% 347 B132R347V5 @ 5% F32T8 - Two Lamp Applications B232SR120V5 @ 100% 120 B232SR120V5 @ 5% B232SR277V5 @ 100% 2 SER-RS 277 B232SR277V5 @ 5% B232SR347V5 @ 100% 347 B232SR347V5 @ 5% B232SR347V5 @ 100% 2 RS 347 B232SR347V5 @ 5% F32T8 - Three Lamp Applications B332SR120V5 @ 100% 120 B332SR120V5 @ 5% 3 SER-RS B332SR277V5 @ 100% 277 B332SR277V5 @ 5% F32T8 - Four Lamp Applications B432SR277V5 @ 100% 4 SER/PAR-RS 277 B432SR277V5 @ 5% B432P277V5-E@ 100% 4 SER-PRS 277 B432P277V5-E@ 5% B432P277V5H-E@ 100% 4 SER-PRS 277 B432P277V5H-E@ 5% Line Input Power Ballast Ballast Min. F/C Current Power Factor Factor Efficacy THD Start Wiring (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. 0.22 0.06 0.10 0.03 0.08 0.02 26 7 26 7 26 7 > .99 > .90 > .99 > .90 > .99 > .90 0.90 0.05 0.90 0.05 0.90 0.05 3.46 0.71 3.46 0.71 3.46 0.71 < 10 < 15 < 10 < 20 < 10 < 30 50/10 50/10 50/10 50/10 50/10 50/10 13 13 13 13 13 13 ST ST ST ST ST ST 0.14 0.04 47 12 > .99 > .90 0.93 0.05 1.98 0.42 <10 <15 50/10 50/10 15 15 -E -E 0.33 0.09 90 22 > .98 > .90 0.88 0.05 0.98 0.23 <10 <15 50/10 0/10 14 14 -E -E 0.27 0.07 0.12 0.03 0.09 0.02 32 8 32 8 32 8 > .99 > .90 > .99 > .90 > .99 > .90 0.88 0.05 0.88 0.05 0.88 0.05 2.75 0.63 2.75 0.63 2.75 0.63 < 10 < 10 < 10 < 15 < 10 < 20 50/10 50/10 50/10 50/10 50/10 50/10 13 13 13 13 13 13 ST ST ST ST ST ST 0.52 0.12 0.23 0.05 0.18 0.04 0.18 0.04 62 13 62 13 62 13 62 13 > .99 > .90 > .99 > .90 > .99 > .90 > .99 > .90 0.88 0.05 0.88 0.05 0.88 0.05 0.88 0.05 1.42 0.38 1.42 0.38 1.42 0.38 1.42 0.38 < 10 < 10 < 10 < 15 < 10 < 15 <10 <15 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 15 15 15 15 15 15 15 15 ST ST ST ST ST ST -E -E 0.77 0.17 0.33 0.07 92 20 92 20 > .99 > .90 > .99 > .90 0.88 0.05 0.88 0.05 0.96 0.25 0.96 0.25 < 10 < 10 < 10 < 15 50/10 50/10 50/10 50/10 17 17 17 17 ST ST ST ST 0.42 0.11 0.42 0.10 0.55 0.12 117 27 115 24 150 28 > .99 > .90 > .99 > .90 > .99 > .90 0.88 0.05 0.88 0.05 1.18 0.06 0.79 0.19 0.77 0.21 0.79 0.22 < 10 < 15 < 10 < 15 < 10 < 15 50/10 50/10 50/10 50/10 50/10 50/10 18 18 14 14 14 14 -ZZ -ZZ -E -E -E -E All models except B232SR347V5 are cULus Listed B232SR347V5 is CSA Certified IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start See page 3-20 for Dimensions and Wiring Diagrams STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAGE 3-18 PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) BALLASTAR ® STEP DIMMING BALLASTS BALLASTAR LIGHT LEVEL SWITCHING • Step Dimming • Rapid Start FOR (1), (2) & (3) T8 LAMPS T8 Straight Lamps • 1-3 Lamp Applications T12 U-Shaped Lamps All models are cULus Listed Line Input Power Ballast Ballast Min. F/C Current Power Factor Factor Efficacy THD Start Wiring (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. 0.14 0.08 0.08 0.05 16 9 16 9 > .95 > .95 > .70 > .70 0.88 0.29 0.88 0.29 5.50 3.22 5.50 3.22 < 15 < 15 < 15 < 15 32/0 32/0 32/0 32/0 12a 12a 12a 12a -A -A -A -A 0.25 0.14 0.12 0.07 30 16 30 16 > .99 > .98 > .88 > .85 0.87 0.30 0.87 0.30 2.90 1.88 2.90 1.88 < 10 < 15 < 10 < 15 32/0 32/0 32/0 32/0 12 12 12 12 -A -A -A -A 0.21 0.10 0.11 0.06 24 12 24 12 > .95 > .90 > .80 > .80 0.85 0.28 0.85 0.28 3.54 2.33 3.54 2.33 < 10 < 10 < 10 < 10 32/0 32/0 32/0 32/0 12a 12a 12a 12a -A -A -A -A 0.39 0.20 0.18 0.09 46 24 46 24 > .98 > .95 > .98 > .90 0.84 0.28 0.84 0.28 1.83 1.17 1.83 1.17 < 10 < 10 < 10 < 10 32/0 32/0 32/0 32/0 12 12 12 12 -A -A -A -A 0.27 0.19 0.12 0.13 0.09 0.06 0.25 0.12 0.12 0.06 32 23 14 33 25 15 29 14 29 14 > .99 > .99 > .98 > .99 > .98 > .95 > .99 > .98 > .85 > .80 0.89 0.60 0.28 0.89 0.63 0.28 0.88 0.29 0.88 0.29 2.78 2.61 2.00 2.70 2.52 1.87 3.03 2.07 3.03 2.07 < 10 < 10 < 10 < 10 < 15 < 20 < 10 < 10 < 10 < 20 50/10 50/10 50/10 50/10 50/10 50/10 32/0 32/0 32/0 32/0 11 11 11 11 11 11 12a 12a 12a 12a ST ST ST ST ST ST ST ST ST ST 0.52 0.38 0.24 0.23 0.17 0.11 0.48 0.24 0.21 0.11 62 45 28 62 45 28 57 28 56 28 > .99 > .95 > .95 > .99 > .95 > .95 > .99 > .99 > .95 > .90 0.88 0.58 0.27 0.88 0.58 0.27 0.88 0.30 0.88 0.30 1.42 1.29 0.96 1.42 1.29 0.96 1.54 1.07 1.57 1.07 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 50/10 50/10 50/10 50/10 50/10 50/10 32/0 32/0 32/0 32/0 12 12 12 12 12 12 12 12 12 12 ST ST ST ST ST ST -A -A -A -A 0.78 0.61 0.40 0.34 0.26 0.16 93 69 43 94 69 43 > .99 > .95 > .95 > .99 > .95 > .95 0.88 0.60 0.30 0.88 0.60 0.30 0.95 0.87 0.70 0.94 0.87 0.70 < 10 < 10 < 10 < 10 < 10 < 10 50/10 50/10 50/10 50/10 50/10 50/10 16 16 16 16 16 16 ST ST ST ST ST ST See page 3-20 for Dimensions and Wiring Diagrams PAGE 3-19 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent Dimming Lamp Starting Line Catalog Qty. Method Volts Number F17T8 - One Lamp Applications B232PUS50-A @ 100% 120 B232PUS50-A @ 50% 1 PRS B232PUS50-A @ 100% 277 B232PUS50-A @ 50% F17T8 - Two Lamp Applications B232PUS50-A @ 100% 120 B232PUS50-A @ 50% 2 PRS B232PUS50-A @ 100% 277 B232PUS50-A @ 50% F25T8 - One Lamp Applications B232PUS50-A @ 100% 120 B232PUS50-A @ 50% 1 RS B232PUS50-A @ 100% 277 B232PUS50-A @ 50% F25T8 - Two Lamp Applications B232PUS50-A @ 100% 120 B232PUS50-A @ 50% 2 SER-RS B232PUS50-A @ 100% 277 B232PUS50-A @ 50% F32T8 - One Lamp Applications B132R120S30 @ 100% 120 B132R120S30 @ 60% B132R120S30 @ 30% B132R277S30 @ 100% 277 B132R277S30 @ 60% 1 RS B132R277S30 @ 30% B232PUS50-A @ 100% 120 B232PUS50-A @ 50% B232PUS50-A @ 100% 277 B232PUS50-A @ 50% F32T8 - Two Lamp Applicationswa B232SR120S30 @ 100% 120 B232SR120S30 @ 60% B232SR120S30 @ 30% B232SR277S30 @ 100% 277 B232SR277S30 @ 60% 2 SER-RS B232SR277S30 @ 30% B232PUS50-A @ 100% 120 B232PUS50-A @ 50% B232PUS50-A @ 100% 277 B232PUS50-A @ 50% F32T8 - Three Lamp Applications B332SR120S30 @ 100% 120 B332SR120S30 @ 60% B332SR120S30 @ 30% 3 SER-RS B332SR277S30 @ 100% 277 B332SR277S30 @ 60% B332SR277S30 @ 30% T8 DIMENSIONS AND WIRING DIAGRAMS DIMMING Overall Dimensions Draw # L ST -E -ZZ ESB ESK GT/HT ESBM ESBMT DP1 DP2 9.50” 16.88” 16.40” 9.50” 16.65” 4.95” 9.50” 9.50” 18.00” 4.95” W 2.40” 1.74” 2.40” 2.38” 1.24” 3.00” 2.38” 2.38” 1.18” 2.93” Mounting Dimensions H M X 1.55” 1.18” 1.50” 1.00” 1.00” 1.18” 1.00” 1.20” 1.18” 1.38” 8.89” 16.28” 15.88” 8.88” 16.30” 4.63” 8.88” 8.88” 17.70” 4.57” 1.69” — 1.69” — — — — — — — DIAGRAM 6 DIAGRAM 13 DIAGRAM 7 -E, ESB, ESK, ESBM, ESBMT, DP1 ST, -ZZ Fluorescent Dimming DIAGRAM 8 DIAGRAM 14 DIAGRAM 9 HT, DP2 GT DIAGRAM 15 WIRING DIAGRAMS DIAGRAM 10 DIAGRAM 1 DIAGRAM 16 DIAGRAM 11 DIAGRAM 2 DIAGRAM 3 DIAGRAM 12 DIAGRAM 17 DIAGRAM 4 DIAGRAM 12a DIAGRAM 18 INDIVIDUALLY CAP YELLOW LEADS DIAGRAM 5 PAGE 3-20 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) BALLASTAR ® STEP DIMMING BALLASTS FOR T5 LAMPS -D -A 16.88” 9.50” 1.18” 1.70” 0.17 0.09 0.09 0.05 21 10 21 10 > .95 > .95 > .75 > .75 1.19 0.40 1.19 0.40 5.90 3.74 5.80 3.50 < 15 < 15 < 15 < 15 50/10 50/10 50/10 50/10 12a 12a 12a 12a -A -A -A -A 0.33 0.15 0.15 0.08 0.29 0.13 0.13 0.06 37.5 18 37 19 35 16 35 16 > .95 > .95 > .90 > .85 > .95 > .95 > .95 > .90 1.15 0.40 1.15 0.40 1.00 0.37 1.00 0.37 3.10 2.19 3.11 2.14 2.86 2.30 2.86 2.29 < 10 < 15 < 10 < 15 < 10 < 10 < 10 < 10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 12 12 12 12 19 19 19 19 -A -A -A -A -D -D -D -D 0.24 0.12 0.12 0.62 0.40 0.18 0.17 0.08 29 14 29 14 48 21 47 22 > .95 > .95 > .85 > .85 > .95 > .95 > .95 > .95 1.18 0.39 1.18 0.40 0.99 0.36 0.99 0.36 4.09 2.84 4.06 2.75 2.06 1.73 2.10 1.65 < 10 < 15 < 15 < 15 < 10 < 10 < 10 < 10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 50/10 12a 12a 12a 12a 19 19 19 19 -A -A -A -A -D -D -D -D 0.50 0.23 0.21 0.10 0.59 0.29 0.25 0.12 58 28 57 28 71 34 69 34 > .99 > .99 > .98 > .95 > .99 > .99 > .98 > .95 0.95 0.35 0.95 0.35 1.15 0.45 1.15 0.45 1.64 1.25 1.67 1.25 1.62 1.32 1.67 1.32 < 10 < 20 < 10 < 20 < 10 < 10 < 10 < 15 50/10 19 -D 50/10 19 -D 50/10 19 -D 50/10 19 -D Mounting Dimensions H M X 1.00” 1.18” 16.20” 8.89” -D — — PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start -A WIRING DIAGRAMS PAGE 3-21 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Fluorescent Dimming W T5 Straight Lamps Line Input Power Ballast Ballast Min. F/C Current Power Factor Factor Efficacy THD Start Wiring (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start Overall Dimensions Draw # L • Programmed Rapid Start • 2 Lamp Applications Lamp Starting Line Catalog Qty. Method Volts Number F14T5 - One Lamp Applications B214PU115S50A @ 100% 120 1 PRS B214PU115S50A @ 50% B214PU115S50A @ 100% 277 B214PU115S50A @ 50% F14T5 - Two Lamp Applications B214PU115S50A @ 100% 120 B214PU115S50A @ 50% B214PU115S50A @ 100% 277 2 PRS B214PU115S50A @ 50% B228PU95S50D @ 100% 120 B228PU95S50D @ 50% B228PU95S50D @ 100% 277 B228PU95S50D @ 50% F21T5 - One Lamp Applications B214PU115S50A @ 100% 120 1 PRS B214PU115S50A @ 50% B214PU115S50A @ 100% 277 B214PU115S50A @ 50% B228PU95S50D @ 100% 120 2 PRS B228PU95S50D @ 50% B228PU95S50D @ 100% 277 B228PU95S50D @ 50% F28T5 - Two Lamp Applications B228PU95S50D @100% 120 B228PU95S50D @50% 2 PRS B228PU95S50D @100% 277 B228PU95S50D @50% B228PU115S50D @100% 120 B228PU115S50D @50% 2 PRS B228PU115S50D @100% 277 B228PU115S50D @50% º Preliminary Data All models are cULus Listed BALLASTAR LIGHT LEVEL SWITCHING • Step Dimming Fluorescent Dimming Notes PAGE 3-22 Compact Fluorescent Ballasts The Courage To Dream Small Universal Lighting Technologies (“Universal”) offers a full range of magnetic and electronic compact fluorescent ballasts. Our magnetic models come in a variety of shapes and sizes, from core and coils to High Power Factor potted ballasts with bottom exit leads and mounting studs for all downlighting applications. Our newest electronic models offer installer-friendly universal input voltage, which reduces your inventory and ensures that you have the right voltage ballast every time. These models feature a low profile case that fits in any fixture. And their metal housing construction meets all plenum codes and delivers maximum heat transfer to extend ballast life. Compact Fluorescent Our newest compact fluorescent models offer installer-friendly universal input voltage. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group Product Overview Electronic Compact Fluorescent Ballasts Universal’s newest TRIAD® electronic compact fluorescent ballasts feature installer-friendly universal input voltage (108 to 305 volts) and metal case designs for compliance with all plenum and construction code requirements. They also offer an end-of-lamp-life shutdown circuit with auto-reset that meets ANSI/NEMA requirements—a feature that eliminates lamp/socket damage while allowing you to replace failed lamps after shutdown without turning off the power. Our universal voltage compact fluorescent ballasts offer both 1- and 2-lamp operation—and they’re ideal for a wide variety of downlight and surface mount applications for atriums, hotel corridors, offices, and outdoors. All models operate multiple lamp types for added versatility in many different applications. All universal voltage compact fluorescent ballasts incorporate Universal’s Programmed Rapid Start (PRS) technology that increases lamp life for those frequently switched applications where occupancy sensors are used. PRS is recommended by all lamp manufacturers. For the Canadian market, we have 347 volt compact fluorescent models. These also offer outstanding reliability and lamp performance. These 347 volt models are available for 1 and 2 lamp operation for lamps ranging from 13 to 70 Watts. These ballasts are designed and manufactured for long life. Lamps can be mounted in close proximity to these ballasts because they have no temperature-critical components near the can sides. And their circuit board potting enhances reliability by lowering case temperatures. CFL Mult-E Kit The multi-exit ballast lead wire connectors accomodate side and bottom lead exit requirements. The snap mount adapter plate adds bottom-exit studs and additional flexibility for replacement of older magnetic ballasts. They also fit virtually every j-box cover and fixture application. This product is for distribution sale only. Compact Fluorescent Mult-E Kit products: C213UNVME000K C218UNVME000K C2642UNVME000K Mult-E Kit contains: Multi-exit ballast Snap-mount adapter plate Lead wire set Wire extraction tool Instructions Magnetic Compact Fluorescent Ballasts Universal offers a complete line of magnetic compact fluorescent ballasts, ranging from 5 - 40 watts (10 - 38 watts for 2D lamps). Both core & coil and F-can models are available...in a variety of configurations that include Side Exit, Bottom Exit and Bottom Exit Studs. FOR MORE INFORMATION CALL PAGE 4-2 1-800-BALLAST (225-5278) Understanding Compact Fluorescent Technology Compact fluorescent (CFL) lamps are single-ended and plug into sockets. They’re sometimes referred to as “single-based” or “single-ended” fluorescent lamps. Lamp Shapes Today’s CFL lamps come in these basic shapes: twin tube, quad, triple, multi and circular. Each of these shapes has its own subset of sizes. For example, the twin tube may range from 4˝ long (5 watt) to 22˝ long (40 watt). OR OR Long Twin T5, 4-Pin 5w – 80w Twin, 2-Pin 5w – 13w In this catalog, Universal CFL ballasts are classified according to lamp type. Icons representing each lamp type provide a quick visual reference. Within each classification, the lamps and their appropriate ballasts can be found by referring to the generic NEMA lamp descriptions. Lamp Designation There are two different industry-recognized nomenclatures for identifying CFL lamps: ANSI Lamp Designations and NEMA Lamp Designations. Here are examples of each: OR 2-Pin 4-Pin Quad 9w – 27w Lamp Bases There are a variety of lamp bases used with today’s CFL lamps. This provides a safeguard to make sure that the proper lamp/ballast combination is installed. The lamp base style is part of the ANSI/NEMA designation. Square (2D) 10w – 55w ANSI Designation 13W / 7T4 / T / GX23 / PH Lamp Wattage Multiple, 4-Pin (GE & OSI) 18w – 70w Multiple, 4-Pin (Philips) 18w – 42w Twin (T) Quad (Q) Multi (M) 2D (S) Lamp Diameter 1/8˝ Base Starting: PH – Preheat RS – Rapid Start NEMA Designation T5 Circular 22w - 55w CFT 13W / GX23 Pins and Starters CFL lamps feature either two pins or four pins. Those with two pins have starters built into their bases, and they require a magnetic preheat ballast. The two-pin CFL lamps are available in wattages from 5 to 28. Twin (T) Quad (Q) Multi (M) 2D (S) Watts 5, 7, 9, 13 9, 13, 18, 20, 26, 27 13, 18, 26, 32, 42 42, 57, 70 18, 24/27, 36/39, 40, 50, 80 10, 16, 21, 28, 38, 55 22, 40, 55 Lamp Wattage Base Both lamp designations refer to lamp wattage, shape, and base type. Since the NEMA designation is shorter, it will probably be the nomenclature of choice in the future. All of the major lamp companies have trade names for various CFL lamp types, such as GE’s “Biax” and “2D” lamps, OSI’s “Dulux,” and Philips’ “PL”. These names have become more widely used than either of the industry designations. GE Low Watt Biax Double Biax Biax T/E Biax Q/E High Lumen Biax 2D — OSI Philips Dulux S, S/E PL-S Dulux D, D/E PL-C Dulux T, T/E, T/E/IN PL-T Dulux T/E/IN PL-T Dulux L, F PL-L –– –– Pentron Silhouette FOR MORE INFORMATION CALL PAGE 4-3 1-800-BALLAST (225-5278) Compact Fluorescent Four-pin lamps are traditionally powered by electronic ballasts. These lamps do not have an internal starter, so the other filament terminals (pins) are made accessible for external connection to the ballasts. Note: Universal offers both magnetic and electronic ballasts for the four-pin 32 and 26 watt lamps and all four-pin Long Twin T5 lamps. Industry Single or Twin Double or Quad Multiple Multiple Long Twin T5 Square Circline Lamp Length Configurations Bottom Exit* Bottom Exit with Studs** Standard Side Exit–Both Ends Electronic Side Exit Electronic Bottom Exit Electronic Bottom Exit with Studs Electronic Multi-Exit Compact Fluorescent Standard Side Exit For full versatility in application according to various fixture requirements, Universal manufactures encased ballasts in three lead and mounting options. This catalog lists ordering codes for standard side exit units. *Bottom exit units should be ordered with suffix “-BE” attached to the catalog number. **Bottom exit with studs should be ordered with suffix “-BES” attached to the catalog number. (Example: Standard Unit: “4000P”; Bottom Exit unit “4000-BE”; Bottom Exit with Studs: “4000-BES”). FOR MORE INFORMATION CALL PAGE 4-4 1-800-BALLAST (225-5278) Product Overview ANSI Lamp Designation NEMA Lamp Designation Built-In Starter GE 5W/4T4/T/G23/PH 7W/5T4/T/G23/PH 9W/6T4/T/G23/PH 13W/7T4/T/GX23/PH CFT5W/G23 CFT7W/G23 CFT9W/G23 CFT13W/GX23 YES YES YES YES F5 BX F7 BX F9 BX F13 BX CF 5DS CF 7DS CF 9DS CF 13DS PL-S 5W PL-S 7W PL-S 9W PL-S 13W 9W/4T4/Q/G23-2/PH 13W/5T4/Q/GX23-2/PH CFQ9W/G23 CFQ13W/GX23 YES YES F9 DBX23 F13 DBX23 CF 9DD CF 13DD — PL-C 13W/USA 13W/6T4/Q/G24d-1/PH 18W/7T4/Q/G24d-2/PH 26W/8T4/Q/G24d-3/PH CFQ13W/G24d CFQ18W/G24d CFQ26W/G24d YES YES YES F13 DBX T4 F18 DBX T4 F26 DBX T4 — CF 18DD CF 26DD PL-C 13W PL-C 18W PL-C 26W CFQ13W/G24q CFQ18W/G24q CFQ26W/G24q NO NO NO F13 DBX/4P F18 DBX/4P F26 DBX/4P CF 13DD/E CF 18DD/E CF 26DD/E PL-C 13W/4P PL-C 18W/4P PL-C 26W/4P 10W/3.5T4/S/GR10q-4 16W/5.5T4/S/GR10q-4 21W/5.5T4/S/GR10q-4 28W/8T6/S/GR8-2/PH 28W/8T6/S/GR10q-4 38W/8T6/S/GR10q-4 55W/8T6/S/GRY10q-3 CFS10W/GR10q CFS16W/GR10q CFS21W/GR10q CFS28W/GR8 CFS28W/GR10q CFS38W/GR10q CFS55W/GRY10q NO NO NO YES NO NO NO F10 2D/4P F16 2D/4P F21 2D/4P F28 2D F28 2D/4P F38 2D/4P F55 2D/4P — — — — — — — — — — — — — — 20W/6T5/Q/GX32d-2/PH 27W/7T5/Q/GX32d-3/PH CFQ20W/GX32d CFQ27W/GX32d YES YES — — — — PL-C 15MM/22W PL-C 15MM/28W CFT13W/2GX7 NO — CF 13DS/E — 18-20W/9T5/T/2G11/PH-RS 18W/10T5/T/2G11/RS 18W/5T5/T/2G10 24-27W/13T5/T/2G11/PH-RS 24W/7T5/T/2G10 36-39W/16T5/T/2G11/PH-RS 36W/9T5/T/2G10 40W/22T5/T/2G11/RS 50W/22T5/T/2G11/RS 55W/21T5/T/2G11 80W/22T5/T/2G11 FT18W/2G11 FT18W/2G11/RS CFM18W/2G10 FT24W/2G11/RS CFM24W/2G10 FT36W/2G11/RS CFM36W/2G10 FT40W/2G11/RS FT50W/2G11/RS FT55W/2G11 FT80W/2G11 NO NO NO NO NO NO NO NO NO NO NO F18 BX F18 BX/RS — F27 BX/RS — F39 BX/RS — F40 BX/RS F50 BX/RS F55 BX — FT 18DL FT 18DL/RS CF 18DF FT 24DL CF 24DF FT 36DL CF 36DF FT 40DL/RS — FT 55DL — — PL-L 18W — PL-L 24W — PL-L 36W — PL-L 40W/RS PL-L 50W/RS — PL-L 80W 18W/5T4/M/GX24d-2 26W/6T4/M/GX24d-3 CFM18W/GX24d CFM26W/GX24d YES YES — — CF 18DT CF 26DT — — 13W/5T4/M/GX24q-1 18W/5T4/M/GX24q-2 26W/6T4/M/GX24q-3 32W/6T4/M/GX24q-3 42W/7T4/M/GX24q-4 57W/7T4/M/GX24q-5 70W/8T4/M/GX24q-6 CFM13W/GX24q CFM18W/GX24q CFM26W/GX24q CFM32W/GX24q CFM42W/GX24q CFM57W/GX24q CFM70W/GX24q NO NO NO NO NO NO NO F13 TBX/4P F18 TBX/4P F26 TBX/4P F32 TBX/4P/EOL F42 TBX/4P/EOL F57 QBX/4P/EOL F70 QBX/4P/EOL CF 13DT/E CF 18DT/E/IN CF 26DT/E/IN CF 32DT/E/IN CF 42DT/E/IN CF 57DT/E/IN — — PL-T 18W/4P PL-T 26W/4P PL-T 32W/4P PL-T 42W/4P — — — — — FC9T5-22W/2GX13 FC12T5-40W/2GX13 FC12T5-55W/2GX13 NO NO NO — — — FPC22 FPC40 FPC55/HO FC9T5 22W FC12T5 40W FC12T5 55W LAMP MANUFACTURER OSI Philips Twin, 2-Pin Quad, 2-Pin Quad, 2-Pin OR 13W/6T4/Q/G24q-1 18W/7T4/Q/G24q-2 26W/8T4/Q/G24q-3 Quad, 4-Pin Square, (2D) T5 Quad, 2-Pin 13W/6T4/T/2GX7 Twin T4, 4-Pin Long Twin T5, 4-Pin Multiple, 4-Pin T5 Circular, 4-Pin FOR MORE INFORMATION CALL PAGE 4-5 1-800-BALLAST (225-5278) Compact Fluorescent Multiple, 2-Pin Specifications Compact Fluorescent TYPICAL SPECIFICATIONS FOR ELECTRONIC COMPACT FLUORESCENT BALLASTS 1. 2. 3. 4. 4a. 5. 6. 7. 8. 9. 10. 11. 12. Ballast shall be Programmed Rapid Start. Ballast shall incorporate lamp shutdown circuitry for end of lamp life protection. Ballast shall allow for re-lamping without the need to cycle power. Ballasts shall operate from 50/60 Hz input source of 120, 277, or 347 Volts with no damage to the ballasts. Ballasts shall operate from 50/60 Hz input source of 108-305 Volts with no damage to the ballasts for High Performance (HP) models. Ballast shall be of metal can construction to meet all plenum requirements and to eliminate the need for extra grounding wires. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 50 kHz to minimize interference with infrared control systems. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and ANSI C82.11-1993. Ballasts shall tolerate operation in ambient temperatures up to 140°F (55°C) without damage. Ballasts shall have a maximum case temperature test point of 75°C printed on the label for easy fixture testing and trouble shooting. Ballast shall have a maximum case temperature rise of 15°C. Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (Radiated). Ballasts shall provide transient immunity as recommended by ANSI C62.41-1991. 13. 14. 15. 16. 17. 18. Ballasts shall operate lamps with no visible flicker (<3% flicker index). Ballasts shall tolerate sustained open and short circuit output conditions without damage. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified, and unless noted otherwise, approved for use in hazardous locations (Type HL). Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp. Ballasts shall have a Power Factor greater than .98 for the primary lamp. The ballasts shall not have any PCB’s. 19. 20. 21. The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of manufacture. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years. Ballast shall be manufactured in an ISO 9001 Certified Facility. 22. Universal model ___________ (or approved equal). FOR MORE INFORMATION CALL PAGE 4-6 1-800-BALLAST (225-5278) Understanding Universal Part Numbers MAGNETIC ELECTRONIC Our part number nomenclature for magnetic ballasts is shown below: Our nomenclature for electronic CFL ballasts follows the system already in place for other Universal electronic ballasts. The exceptions are that the model number prefix for compact fluorescent is a C rather than a B—and the suffixes for the mounting configuration will be the same as those used for magnetic products (BE and BES). If you don’t see these suffixes, the ballast has traditional side exit leads. Odd = NPF Even = HPF Thermally Protected Color: 001 – White 000 – Black 4XXX XX P XXX XXX X 1 – 120V 2 – 277V 3 – 347V F1 – Frame F2 – Fr. w/feet H2 – Cover/Fr. No suffix – Side Exit BE – Bottom Exit BES – Bottom Exit with Studs Lamp Wattage C – Carton T – Tray Pack UNV or 347V Color: 001-White 000-Black CXXX XX XXX XXX XXX X Example: 4123PBES000T Ballast for CFL Lamps: Indicated by “4” prefix Voltage: 120V Lamp Type: 26W Quad Lamp (refer to catalog for wattage) Power Factor: Normal Encased and Potted: Indicated by absence of F1, F2, or H2) P: Thermally protected BES: Bottom exit leads with studs 000: Color—Black T: Packaging container style—Tray Pack # of lamps These ballasts are available for a wide variety of applications with lamps, voltages, mounting configurations, and performance characteristics. For more detailed information, just identify the lamps to be ballasted and work forward to determine the ballast part number. SR-Series, Rapid Start R-Rapid Start No suffix or SE – C-Carton Side Exit T-Tray Pack BE – Bottom Exit I-Individual BES – Bottom Exit K-Replacement Kit with Studs ME-Multi Exit MES-Multi Exit with Studs Example:Electronic C240PUNVHP-B Ballast Type: C — CFL Electronic Ballast Lamp Qty: 2 Lamp Type: 40W TT5, 4 Pin (FT40W/2611) P: Programmed Rapid Start Voltage: UNV 120 to 277 volts HP-B: High Performance <10%; low profile can 000: Color—Black C: Packaging container style—Carton Pack Lamp Wattage* 120V, 277V 347V, UNV (120-277) Colors 000 – Black 001 – White CXXX X XXX XXX XXX # of Lamps No suffix=P P=Programmed Rapid Start I=Instant Start X T = Tray Pack SE – Side Exit C – Carton Pack BE – Bottom Exit I – Individual BES – Bottom K-Replacement Kit Exit/Studs ME– Multi Exit MES– Multi Exit with Studs HP-B – Low Profile RH – Reduced Harmonics *Exception is C2642, which does not distinguish number of lamps. See catalog. FOR MORE INFORMATION CALL PAGE 4-7 1-800-BALLAST (225-5278) Compact Fluorescent Example: C213UNVBES000C* Ballast Type: C Lamp Quantity: 2 Lamp Type: 13W Quad, 4 Pin (CFQ13W/G24q) Voltage: UNV 120 to 277 volts BES: Bottom exit connection, studs 000C: Color—Black C: Packaging container style—Carton Pack TWIN LAMPS • Open core & coil or encased & potted designs OR MAGNETIC AND ELECTRONIC COMPACT FLUORESCENT BALLASTS • 1 & 2 lamp models available 5, 7, 9 & 11 WATTS • Ideal for surface mount fixtures, exit & retail display signs QUICK REFERENCE Nominal lamp watts and configuration Lamp Type 7 Watts CFT7W/G23 Mag Qty Line or of Line Catalog Input Current Elec Lamps Volt Number Watts Amps Electrical Characteristics - 60 Hz ❍ M 1 120 4105F2P ■★ 10 0.18 M 1 120 4105P 10 0.18 FOR TWIN LAMPS 5, 7, 9 AND 11 WATTS Lead Configuration Starting Min Current Ballast Start Power Side Bottom Bottom Starting Wir Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag 0.20 0.20 0.95 0° F Normal <10% X 0.95 0° F Normal <10% X — — — — PH PH B2 1 C1 1 0.20 0.20 0.90 25° F Normal <10% X 0.90 25° F Normal <10% X — — — — PH PH B2 1 C1 1 Twin, 2-Pin Lamp Type 9 Watts CFT9W/G23 OR CFQ9W/G23 ❍ M M 1 1 120 4105F2P ■★ 10 120 4105P 10 0.18 0.18 OR Twin or Quad, 2-Pin ★ Non-thermally protected models available. ✿ PH = Preheat F2 indicates an open core & coil unit with mounting feet. ■ H2 indicates clamped & covered core & coil with mounting feet. µ Add “B” for Bottom Exit or “S” for Side Exit or “BS” for Bottom Exit with 2” O.C. screw studs. ❍ Not approved for use in hazardous locations. Compact Fluorescent { The encased ballasts listed on this page are available in white (001) or black (000) cans, except CBT’s, which are all in white cans. All ballasts are UL listed, CSA approved See page 4-13 for Dimensions and Wiring Diagrams. FOR MORE INFORMATION CALL PAGE 4-8 1-800-BALLAST (225-5278) MAGNETIC AND ELECTRONIC COMPACT FLUORESCENT BALLASTS FOR TWIN, QUAD AND MULTIPLE LAMPS 13 WATTS QUICK REFERENCE Mag Qty Line or of Line Catalog Input Current Elec Lamps Volt Number Watts Amps Lamp Type Electrical Characteristics - 60 Hz ❍ M 13 Watts 1 120 CF1320H2P ■ 16 0.24 CFT13W/GX23 ❍ M 1 120 4113P 14 0.24 OR ❍ M 1 277 4211F2P ■★ 22 0.16 CFQ13W/GX23 ❍ M 1 277 4211PBES 22 0.16 M 1 120 4112P 14 0.13 M 1 120 4113P 14 0.24 M 1 277 4210PBES 21 0.10 OR M 2 120 4114P 31 0.26 2 277 4214PBES 26 0.09 Twin or Quad, M Nominal lamp watts and configuration TWIN, QUAD & MULTIPLE LAMPS • Ideal for downlights & wall sconces • E lectronic models feature universal input voltage from 120V to 277V. 347V models are also available. OR 13 WATTS • E lectronic models feature programmed rapid start for excellent lamp performance & auto reset shutdown circuit Lead Configuration Starting Min Current Ballast Start Power Side Bottom Bottom Starting Wir Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag 0.30 0.36 0.35 0.35 0.14 0.36 0.11 0.33 0.09 0.85 0.80 1.00 1.00 0.80 0.90 1.00 0.95 0.85 32° F 32° F 32° F 32° F 32° F 32° F 32° F 32° F 32° F Normal Normal Normal Normal High Normal High High High <15% <10% <10% <10% <20% <10% <20% <20% <20% X X X X X X X X X — — — — X X X — — — — — — X X X X X PH PH PH PH PH PH PH PH PH B10 C2 B3 C3 C2 C2 C3 C5 C4 1 1 1 1 2 1 2 8 9 2-Pin U.S. type Lamp Type 13 Watts CFQ13W/G24q OR CFM13W/GX24q 120 E 1 C213UNV ◆r 18 277 120 E 2 C213UNV ◆r 30 277 1 18 E 347 C213/347◆ 2 33 0.15 <10% —— 1.00 0° F High X X X PRS C10 0.07 <15% 0.26 —— 1.00 0° F High <10% X X X PRS C10 0.11 0.06 —— 1.00 0°F High <10% X X X PRS C10 0.10 —— 0.98 18 19 18 19 OR Quad or Multiple, 4-Pin Lamp Type 13 Watts CFT13W/2GX7 E 1 E 2 120 CT213UNV ◆ 15 277 120 CT213UNV ◆ 26 277 0.12 <10% —— 0.98 0°F High X 0.06 <12% 0.22 —— 0.98 0°F High <10% X 0.10 X X PRS C10 20✛ X X PRS C10 20 Non-thermally { See page 4-13 for Dimensions and Wiring Diagrams. PAGE 4-9 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Compact Fluorescent protected models available. The encased ballasts listed on this page are available in white (001) or black (000) ✿ PH = Preheat; PRS = Programmed Rapid Start; RS=Rapid Start cans, except CBT’s, which are all in white F2 indicates an open core & coil unit with mounting feet. cans. H2 indicates clamped & covered core & coil with mounting feet. Twin T4, All ballasts are UL listed, CSA approved ■ ◆ Add following suffix for complete catalog #: “SE” for Side Exit 4-Pin connectors, “BE” for Bottom Exit connectors, “BES” for Bottom Exit connectors with 2˝ O.C. screw studs, "ME" for Multi Exit connectors, or "MES" for Multi Exit with 2" OC screw studs. ❍ Not approved for use in hazardous locations. rAdd “ME000K” suffix for Mult-E Kit. For Distribution only. TWIN, QUAD & MULTIPLE LAMPS • Ideal for downlights, surface mount & outdoor fixtures • E lectronic models feature universal input voltage from 120V to 277V. 347V models are also available. • Electronic models feature programmed rapid start for excellent lamp performance & auto reset shutdown circuit OR 18 WATTS QUICK REFERENCE Nominal lamp watts and configuration Lamp Type 18 Watts CFQ18W/G24d Mag Qty Line or of Line Catalog Input Current Elec Lamps Volt Number Watts Amps Electrical Characteristics - 60 Hz M 2 120 4122PBES 50 0.45 MAGNETIC AND ELECTRONIC COMPACT FLUORESCENT BALLASTS FOR TWIN, QUAD AND MULTIPLE LAMPS 18 WATTS Lead Configuration Starting Min Current Ballast Start Power Side Bottom Bottom Starting Wir Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag 0.27 0.88 15° F High <20% — — X PH C6 10 Quad, 2-Pin Lamp Type 18 Watts CFQ18W/G24q OR CFM18W/GX24q OR 120 E 1 C218UNV ◆r 19 277 120 E 2 C218UNV◆r 35 277 1 21 E 347 C218/347◆ 2 38 0.16 <10% —— 1.00 0° F High X X X PRS C10 0.07 <15% 0.30 —— 0.95 0° F High <10% X X X PRS C10 0.13 0.11 —— 1.00 0°F High <10% X X X PRS C10 0.06 —— 0.98 18 19 18 19 Quad or Multiple, 4-Pin Lamp Type 18 Watts FT18W/2G11RS E 1 E 2 120 CT218UNVSE◆ 23 277 120 43 CT218UNVSE◆ 277 42 0.19 0.07 0.37 0.16 —— —— 1.00 0.98 0° F 0° F High <10% X High <10% X __ PRS C10 18 __ __ PRS C10 19 The encased ballasts listed on this page are available in white (001) or black (000) cans, except CBT’s, which are all in white cans. All ballasts are UL listed, CSA approved and designated Class P (thermally protected), Type HL. Compact Fluorescent ✿ PH = Preheat; PRS = Programmed Rapid Start; RS=Rapid Start ◆ Add following suffix for complete catalog #: “SE” for Side Exit connectors, “BE” for Bottom Exit connectors, “BES” Twin T5, for Bottom Exit connectors with 2˝ O.C. screw studs, "ME" for 4-Pin, Multi Exit connectors, or "MES" for Multi Exit with 2" OC screw studs. rAdd “ME000K” suffix for Mult-E Kit. For Distribution only. __ See page 4-13 for Dimensions and Wiring Diagrams. FOR MORE INFORMATION CALL PAGE 4-10 1-800-BALLAST (225-5278) MAGNETIC AND ELECTRONIC COMPACT FLUORESCENT BALLASTS • Ideal for downlights, surface mount & outdoor fixtures • Electronic models feature universal input voltage from120V to 277V. 347V models are also available. • Electronic models feature programmed rapid start for excellent lamp performance & auto reset shutdown circuit FOR QUAD AND MULTIPLE LAMPS 26 AND 28 WATTS QUICK REFERENCE Nominal lamp watts and configuration Lamp Type 26 Watts CFQ26W/G24d Quad, 2-Pin Lamp Type 26 Watts CFQ26W/G24q OR CFM26W/GX24q OR Mag Qty Line or of Line Catalog Input Current Elec Lamps Volt Number Watts Amps Electrical Characteristics - 60 Hz M 1 120 4124PBES 30 0.27 M 1 120 4124PBES 30 0.27 M 2 120 4128PBES 61 0.55 M 2 277 4226PBES 62 0.22 120 E 1 C2642UNV ◆r 28 277 120 E 2 C2642UNV◆r 56 277 31 1 E 347 C2642/347◆ 2 57 120 56 ◆ E 2 C242UNV 277 55 E 2 347 C242/347◆ 44 0.25 0.11 0.47 0.21 0.09 0.17 0.46 0.20 0.14 QUAD AND MULTIPLE LAMPS OR 26 & 28 WATTS Lead Configuration Starting Min Current Ballast Start Power Side Bottom Bottom Starting Wir Amps Factor Temp Factor THD Exit Exit Exit Studs Method_ Dim Diag 0.46 0.46 0.38 0.34 0.88 0.88 0.90 0.90 —— 25° F 25° F 32° F 32° F High High High High <30% < 30% <20% <20% — — X X X — — — — X X X PH PH PH PH C4 C4 C6 C4 3 3 16 8 1.02 0° F High <10% X X X PRS C10 18 —— 0.98 0° F High <10% X X X PRS C10 19 —— —— 1.02 18 0°F High <10% X X X PRS C10 0.98 19 —— 1.02 0° F High <10% X X X PRS C11 19 —— 1.02 0° F High <10% X X X PRS C11 19 Quad or Multiple, 4-Pin ❍ M 1 120 4139F2P■ 32 0.65 0.84 0.95 15° F Normal <10% X — — PH B3 1 Lamp Type 28 Watts CFQ28W/GX32d ✿ PH = Preheat; PRS = Programmed Rapid Start; RS = Rapid Start The encased ballasts listed on this page ■ F2 indicates an open core & coil unit with mounting feet. are available in white (001) or black (000) cans, except CBT’s, which are all in white ◆ Add following suffix for complete catalog #: “SE” for Side Exit cans. connectors or “BE” suffix for Bottom Exit connectors or “BES” All ballasts are UL listed, CSA approved for Bottom Exit connectors with 2˝ O.C. screw studs. T5 Quad, 2-Pin ❍ Not approved for use in hazardous locations. rAdd “ME” suffix for Mult-E Kit. For Distribution only. µ Add “B” for Bottom Exit or “S” for Side Exit or “BS” for Bottom Exit with 2” O.C. screw studs. Compact Fluorescent See page 4-13 for Dimensions and Wiring Diagrams. PAGE 4-11 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) MULTIPLE LAMPS 32, 42, 57 & 70 WATTS QUICK REFERENCE Nominal lamp watts and configuration Lamp Type 32 Watts CFM32W/GX24q Multiple, 4-Pin Lamp Type 42 Watts CFM42W/GX24q Multiple, 4-Pin Lamp Type 57 Watts CFM57W/GX24q Multiple, 4-Pin Compact Fluorescent Lamp Type 70 Watts CFM70W/GX24q ELECTRONIC COMPACT FLUORESCENT BALLASTS FOR MULTIPLE LAMPS • Ideal for downlights, surface mount & outdoor fixtures • E lectronic models feature universal input voltage from 120V to 277V. 347V models are also available. • Electronic models feature programmed rapid start for excellent lamp performance & auto reset shutdown circuit Mag Qty Line or of Line Catalog✪ Input Current Elec Lamps Volt Number Watts Amps Electrical Characteristics - 60 Hz 120 0.30 E 1 C2642UNV◆r 36 277 0.13 E 1 347 C2642/347◆ 36 0.11 120 69 0.58 E 2 C242UNV◆ 277 67 0.26 E 2 347 C242/347◆ 62 0.19 E 1 E 1 E 1 E 2 E 1 E 2 E 1 E 1 120 C2642UNV◆r 48 277 347 C2642/347◆ 50 120 C242UNV◆ 45 277 120 91 C242UNV◆ 277 90 347 C242/347◆ 42 347 C242/347◆ 80 120 58 ◆ C242UNV 277 57 347 C242/347◆ 61 E 1 E 1 120 C242UNV◆ 277 347 C242/347◆ 0.41 0.18 0.15 0.40 0.18 0.76 0.32 0.13 0.25 0.52 0.21 0.18 32, 42, 57 & 70 WATTS Lead Configuration Starting Min Current Ballast Start Power Side Bottom Bottom Starting Wir Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag —— 1.00 0° F High <10% X X X —— 0.98 0° F High <10% X X X PRS C10 18 —— 1.00 0° F High <10% X X X PRS C11 19 —— 1.00 0° F High <10% X X X PRS C11 19 —— 0.98 0° F High <10% X X X PRS C10 18 —— 1.00 0° F High <10% X X X PRS C10 18 —— 1.00 0° F High <10% X X X PRS C11 19 —— 0.98 0° F High <10% X X X PRS C11 19 —— —— 1.00 0° F 0.98 0° F High <10% X High <10% X X X X X PRS C11 18 PRS C11 19 —— 1.00 0° F High <10% X X X PRS C11 19 —— 1.00 0° F High < 10% X X X PRS C11 19 1.00 0° F High <10% X X X PRS C11 19 1.00 0° F High < 10% X X X PRS C11 19 73 0.61 —— 72 0.27 74 0.21 —— PRS C10 18 Multiple, 4-Pin ✿ RS = Rapid Start; PRS = Programmed Rapid Start The encased ballasts listed on this page are ◆ Add following suffix for complete catalog #: “SE” for Side Exit available in white (001) or black (000) cans. connectors or “BE” suffix for Bottom Exit connectors or “BES” All ballasts are UL listed, CSA approved and designated Class P (thermally protected), Type for Bottom Exit connectors with 2˝ O.C. screw studs. HL. rAdd “ME” suffix for Mult-E Kit. For Distribution only. µ Add “B” for Bottom Exit or “S” for Side Exit or “BS” for Bottom Exit with 2” O.C. screw studs. See page 4-13 for Dimensions and Wiring Diagrams. FOR MORE INFORMATION CALL PAGE 4-12 1-800-BALLAST (225-5278) TWIN, TRIPLE, QUAD & MULTIPLE LAMPS MAGNETIC AND ELECTRONIC COMPACT FLUORESCENT BALLASTS WIRING DIAGRAMS AND DIMENSIONS REFERENCE DRAWING FOR B1-B3 WIRING DIAGRAMS C D Install in accordance with National Electrical Code. B A E Dwg. A B1 B2 B3 0.84” 1.23” 1.50” B C 1.41” 1.64” 1.95” D 1.72” 1.97” 2.34” E 2.00” 2.38” 2.81” 2.38” 2.81” 3.25” Black Lead Lengths: 10˝-12˝ REFERENCE DRAWING FOR C1, C2 E C B Dwg. C1 C2 REFERENCE DRAWING FOR C3, C4, C5 D A A B 17/64" A B C D E 1.84” 1.84” 1.09” 1.42” 2.06” 2.40” 2.41” 2.75” 2.75” 3.13” B C D E F C3 C4 C5 2.14” 2.34” 1.88” 1.56” 1.53” 1.47” 3.50” 5.45” 5.13” 4.31” 6.00” 6.00” 4.75” 6.59” 6.44” 0.22” 0.31” 0.25” Dwg. C6 A B 2.38” 1.53” C F A 111/16" F 5/16" C D 8.31” 8.89” E F 9.48” 1.19” Dwg. C10 A B Black C Line D E F Red DIAGRAM 3 G Leadless-Poke-in wire connection White Blue BALLAST Blue Line Black Blue E F DIAGRAM 8 Parallel lamp operation White Red BALLAST BALLAST Line Black Blue DIAGRAM 17 Series lamp operation G C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.55” 1.00” Leadless-Poke-in wire connection White BALLAST Black White Green REFERENCE DRAWING FOR CBT Red Red BALLAST Blue Blue DIAGRAM 18 Ballast should be groundBlack White Green BALLAST Red Red Yellow Yellow Blue Blue DIAGRAM 19 Series lamp operation Ballast should be grounded Black Blue Line DIAGRAM 9 Series lamp opera- Red White Green Black Red BALLAST Yellow Yellow Blue Blue White Red BALLAST Black Blue Line DIAGRAM 10 Parallel lamp operation Dwg. A B C D E CBT 3.86” 2.00” 1.00” 3.50” —— DIAGRAM 20 Series lamp opera- PAGE 4-13 DIAGRAM 47 DIAGRAM 48 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Compact Fluorescent Black DIAGRAM 16 Series lamp operation D Blue BALLAST 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00” White C DIAGRAM 2 White D E Line B Line G REFERENCE DRAWING FOR C11 A Blue BALLAST Black B Lead Lengths: Side • Black/White– 11˝ • Red/Blue–12˝ BE/BES–8˝ Dwg. White Lead Lengths: Side–12˝ BE/BES–8˝ E D A F 15/ " 16 A REFERENCE DRAWING FOR C10 REFERENCE DRAWING FOR C6 B DIAGRAM 1 Dwg. Lead Lengths: Side–12˝ BE/BES–8˝ C Line E D C 3/ " 16 BALLAST Black 2D LAMPS • Ideal for surface mount fixtures • All magnetic models are encased & potted. • Magnetic and electronic models available. • E lectronic models feature universal input voltage from 120V to 277V. 347V models are also available. • Electronic models feature programmed rapid start for excellent lamp performance & auto reset shutdown circuit 10, 16 & 21 WATTS QUICK REFERENCE Nominal lamp watts and configuration Lamp Type 10 Watts CFS10W/GR10q 2D, 4-Pin Lamp Type 16 Watts CFS16W/GR10q 2D, 4-Pin Lamp Type 21 Watts CFS21W/GR10q Compact Fluorescent 2D, 4-Pin MAGNETIC & ELECTRONIC COMPACT FLUORESCENT BALLASTS FOR 2D LAMPS 10, 16 AND 21 WATTS Lead Configuration Mag Qty Line Starting Min or of Line Catalog Input Current Current Ballast Start Power Side Bottom Bottom Starting Wir Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag Electrical Characteristics - 60 Hz 120 0.12 <10% E 1 C213UNV◆r 15 —— 1.02 0° F High X X X PRS C10 18a 277 0.06 <15% 120 0.22 E 2 C213UNV◆r 26 —— 1.02 0° F High <10% X X X PRS C10 19a 277 0.10 E 1 347 C213/347◆ 16 0.05 —— 1.02 0° F High <10% X X X PRS C10 18a E 2 347 C213/347◆ 28 0.08 —— 1.02 0° F High <10% X X X PRS C10 19a E 1 E 1 E 2 E 2 120 C213UNV◆r 19 277 20 347 C213/347◆ 120 C213UNV◆r 33 277 347 C213/347◆ 34 0.15 —— 0.95 0° F High 0.07 0.06 —— 0.95 0°F High 0.28 —— 0.95 0° F High 0.12 0.10 —— 0.95 0°F High <10% X <15% <10% X X X PRS C10 18a X X PRS C10 18a <10% X X X PRS C10 19a <10% X X X PRS C10 19a E 1 E 1 E 2 E 2 120 C218UNV◆r 24 277 347 C218/347◆ 21 120 C218UNV◆r 43 277 347 C218/347◆ 39 0.18 —— 0.98 0° F High 0.08 0.06 —— 0.98 0° F High 0.37 —— 0.95 0° F High 0.16 0.12 —— 0.95 0° F High <10% <15% <10% <10% <15% <10% X X X PRS C10 18a X X X PRS C10 18a X X X PRS C10 19a X X X PRS C10 19a ● Starter required: use COP-40 or FS-4 type fluorescent starter. ✿ PH = Preheat; PRS = Programmed Rapid Start ◆ Add following suffix for complete catalog #: “SE” for Side Exit connectors, “BE” for Bottom Exit connectors, “BES” for Bottom Exit connectors with 2˝ O.C. screw studs, "ME" for Multi Exit connectors, or "MES" for Multi Exit with 2" OC screw studs. rAdd “ME000K” suffix for Mult-E Kit. For Distribution only. The encased ballasts listed on this page are available in white (001) or black (000) cans. All ballasts are UL listed, CSA approved and designated Class P (thermally protected), Type HL. See page 4-16 for Dimensions and Wiring Diagrams. PAGE 4-14 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) MAGNETIC & ELECTRONIC COMPACT FLUORESCENT BALLASTS FOR 2D LAMPS 28, 38 & 55 WATTS QUICK REFERENCE Nominal lamp watts and configuration Lamp Type 28 Watts CFS28W/GR8 2D, 2-Pin Lamp Type 28 Watts CFS28W/GR10q Mag Qty Line or of Line Catalog✪ Input Current Elec Lamps Volt Number Watts Amps Electrical Characteristics - 60 Hz M 1 120 4124PBES 37 0.34 M 1 120 4124PBES 37 0.34 M 2 120 4128PBES 61 0.55 M 2 277 4226PBES 66 0.23 E 1 E 1 E 2 E 2 120 C2642UNV◆r 31 277 347 C2642/347◆ 33 64 120 C242UNV◆ 277 63 347 C242/347◆ 60 0.27 0.12 0.10 0.54 0.24 0.18 E 1 120 C2642UNV◆r 33 277 0.27 0.12 2D LAMPS • Ideal for surface mount fixtures • All magnetic models are encased & potted • Magnetic & electronic models available • E lectronic models feature universal input voltage from 120V to 277V. • Electronic models feature programmed rapid start for excellent lamp performance & auto reset shutdown circuit 28, 38 & 55 WATTS Lead Configuration Starting Min Current Ballast Start Power Side Bottom Bottom Starting Wir Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag 0.46 0.46 0.38 0.34 0.88 0.88 0.90 0.93 —— 32° F 32° F 32° F 25° F High High High High <20% <20% <20% <20% — — X X X — — — — X X X PH PH PH PH C4 C4 C6 C4 1a 1a 13a 7a 0.95 0° F High <10% X X X PRS C10 18a —— 0.95 0°F High <10% X X X PRS C10 18a —— 1.00 0° F High <10% X X X PRS C11 19a —— 1.00 0°F High <10% X X X PRS C11 19a —— 0.80 0°F High <10% X — X PRS C10 18a 2D, 4-Pin Lamp Type 38 Watts CFS38W/GR10q 2D, 4-Pin ✿ PH = Preheat; PRS = Programmed Rapid Start ◆ Add following suffix for complete catalog #: “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or “BES” for Bottom Exit connectors with 2˝ O.C. screw studs. rAdd “ME” suffix for Mult-E Kit. For Distribution only. The encased ballasts listed on this page are available in white (001) or black (000) cans. All ballasts are UL listed, CSA approved and designated Class P (thermally protected), Type HL. Compact Fluorescent See page 4-16 for Dimensions and Wiring Diagrams. FOR MORE INFORMATION CALL PAGE 4-15 1-800-BALLAST (225-5278) MAGNETIC & ELECTRONIC COMPACT FLUORESCENT BALLASTS FOR 2D LAMPS 2D LAMPS WIRING DIAGRAMS AND DIMENSIONS WIRING DIAGRAMS REFERENCE DRAWING FOR C4, C5 Install in accordance with National Electrical Code. E D C A B F 15/16" Dwg. A B C D E F C4 C5 2.34” 1.88” 1.53” 1.47” 5.45” 5.13” 6.00” 6.00” 6.59” 6.44” 0.31” 0.25” White White Black Lead Lengths: Side–12˝ BE/BES–8˝ Red BALLAST Black Blue BALLAST White Blue Blue Black DIAGRAM 7a Parallel lamp opera- DIAGRAM 1a E D A B Dwg. A B C6 2.40” 1.55” Line DIAGRAM 13a Series lamp operation S D E 8.31” 8.89” Black White Green 9.50” 1.19” F A Blue White DIAGRAM 5a Black BALLAST BALLAST DIAGRAM 18a Blue Line DIAGRAM 9a Parallel lamp operation Black White BALLAST Red Red Yellow Yellow Blue Blue D E D Blue Blue Blue Green C Red Red G B Compact Fluorescent White BALLAST Line REFERENCE DRAWING FOR C10 B FS-4 F Black A S FS-4 5/16" Lead Lengths: Side–12˝ BE/BES–8˝ Dwg. S FS-4 111/16" F C C Blue Line Line REFERENCE DRAWING FOR C6 C Red BALLAST E C10 2.31” 1.00” 4.25” 4.61” 4.94” F G 0.98” 1.00” DIAGRAM 19a Series lamp operation Leadless-Poke-in wire connection REFERENCE DRAWING FOR C11 Dwg. A B C D E F G C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.55” 1.00” Leadless-Poke-in wire connection FOR MORE INFORMATION CALL PAGE 4-16 1-800-BALLAST (225-5278) ELECTRONIC COMPACT FLUORESCENT BALLASTS 22, 40 & 55 WATTS QUICK REFERENCE Nominal lamp watts and configuration Lamp Type 22 Watts FC9T5-22W T5 CIRCULAR Lamp Type 40 Watts FC12T5-40W T5 CIRCULAR Lamp Type 22 & 40 Watts FC9T5-22W & FC12T5-40W T5 CIRCULAR LAMPS • Ideal for surface mount fixtures • E lectronic models feature universal input voltage from 120V to 277V. 347V models are also available. • Electronic models feature rapid and programmed rapid start for excellent lamp performance & auto reset shutdown circuit Mag Qty Line or of Line Catalog✪ Input Current Elec Lamps Volt Number Watts Amps Electrical Characteristics - 60 Hz 120 0.21 E 1 C2642UNV◆r 25 277 0.10 E 1 347 C2642/347◆ 26 0.08 E 2 E 2 120 C242UNV◆ 50 277 347 C242/347◆ 47 0.42 0.19 0.14 E 1 E 1 E 2 E 2 120 C2642UNV◆r 42 277 347 C2642/347◆ 40 80 120 C242UNV◆ 277 79 347 C242/347◆ 71 0.35 0.16 0.12 0.65 0.29 0.22 22,40 & 55 WATTS WIRING DIAGRAMS Lead Configuration Starting Min Current Ballast Start Power Side Bottom Bottom Starting Wir Install in accordance with Amps Factor Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag National Electrical Code. —— 1.00 0° F High <10% X X X PRS C10 28 —— 0.98 0° F High <10% X X X PRS C10 28 —— 1.05 0° F High <10% X X X PRS C11 23 —— 1.05 0° F High <10% X X X PRS C11 23 —— 0.98 0° F High <10% X X X PRS C10 28 —— 0.98 0° F High <10% X X X PRS C10 28 —— 0.98 0° F High <10% X X X PRS C11 23 —— 0.98 0° F High <10% X X X PRS C11 23 Black White Green E 2 T5 CIRCULAR Lamp Type ❍ E 1 55 Watts FC12T5-55W ❍ E 2 120 C242UNV◆ 277 66 64 120 C242/347◆ 59 277 120 B254PUNV-D 56 277 120 106 B254PUNV-D 277 103 0.54 0.24 0.18 Yellow Blue DIAGRAM 23 Series lamp operation Black White Green E 2 Red BALLAST Red BALLAST Blue —— 0.98 0° F High <10% X X X PRS C11 23 —— 0.98 0° F High <10% X X X PRS C11 23 0.87 0° F High <10% X — — PRS -D 28 0.85 0° F High <10% X — — PRS -D 23 0.46 —— 0.21 0.88 —— 0.38 DIAGRAM 28 DIAGRAM 47 ✿ PRS = Programmed Rapid Start; RS=Rapid Start ◆ Add following suffix for complete catalog #: “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or “BES” for Bottom Exit connectors with 2˝ O.C. screw studs. µ Add “B” for Bottom Exit or “S” for Side Exit or “BS” for Bottom Exit with 2” O.C. screw studs. ❍ Not approved for use in hazardous locations. Compact Fluorescent T5 CIRCULAR The encased ballasts listed on this page are available in white (001) or black (000) cans, except CBT’s, which are all in white cans. All ballasts are UL listed, CSA approved and designated Class P (thermally protected). REFERENCE DRAWING FOR C11 REFERENCE DRAWING FOR C10 C F A G B Dwg. D E A B C D E F G C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.56” 1.00” Dwg. A B C D E F G C10 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00” Leadless-Poke-in wire connection Leadless-Poke-in wire connection REFERENCE DRAWING FOR CBT REFERENCE DRAWING FOR -D Dwg. -D L W 16.88” 1.16” H M 1.00” 16.28” X --- PAGE 4-17 Dwg. A B C D E CBT 3.86” 2.00” 1.00” 3.50” —— LONG TWIN T5 LAMPS • Ideal for track light & surface mount fixtures • Electronic models feature universal input voltage from 120V to 277V. 347V models are also available • Electronic models feature rapid and programmed rapid start for excellent lamp performance & auto reset shutdown circuit 18, 24/27 WATTS QUICK REFERENCE Nominal lamp watts and configuration Lamp Type 18 Watts FT18W/2G11/RS Long Twin T5, 4-Pin Mag Qty Line Starting or of Line Catalog Input Current Current Ballast Elec Lamps Volt Number Watts Amps Amps Factor Electrical Characteristics - 60 Hz E 1 120 CBT126L-120µ 20 0.36 —— 1.10 120 0.19 —— E 1 CT218UNVSE 23 1.00 277 0.07 —— 120 43 0.37 —— E 2 CT218UNVSE 0.98 277 42 0.16 —— 1 ❍ E 2 E 1 E 2 Long Twin T5, E 2 4-Pin E 1 E 2 Lamp Type 24/27 Watts FT24W/2G11/RS Lamp Type 24/27 Watts CFM24W/2G10 Compact Fluorescent T5 F-Lamp, 4-Pin ❍ E 120 B224PUNV-C 27 277 120 52 B224PUNV-C 277 51 347 C2642/347◆ 29 120 51 C242UNV◆ 277 50 347 C242/347◆ 49 120 C2642UNV 26 277 120 47 C2642UNV 277 49 ELECTRONIC COMPACT FLUORESCENT BALLASTS FOR LONG TWIN T5 LAMPS 18 AND 24/27 WATTS (BIAX, DULUX L AND PLL) Lead Configuration Min Start Power Side Bottom Bottom Starting Wir Temp Factor THD Exit Exit Exit Studs Method✿ Dim Diag 0° F Normal <150% High <10% High <10% X X X X X X — — — — X — — — — RS PRS PRS PRS PRS <10% X <15% — — PRS -C 29 <10% X — — PRS -C 29 0° F 0° F 0.23 —— 1.05 0° F High 0.10 0.43 —— 1.00 0° F High 0.18 0.09 —— 0.90 0° F High 0.43 —— 1.02 0° F High 0.19 0.14 —— 1.02 0° F High 0.22 —— 1.01 0° F High 0.10 0.40 —— 0.98 0° F High 0.18 CBT C10 C10 C10 C10 47 21 21 20 20 <10% X X X PRS C10 21 <10% X X X PRS C11 20 <10% X X X PRS C11 20 <10% X X X PRS C10 21 <10% X X X PRS C10 21 120 0.20 <10% 1 B224PUNV-C 24 —— 1.05 0° F High X — — PRS -C 29 277 0.09 <15% 120 48 0.40 ❍ E 2 B224PUNV-C —— 1.00 0° F High <10% X — — PRS -C 29 277 47 0.17 ✿ RS = Rapid Start; PRS = Programmed Rapid Start The encased ballasts listed on this page ❍ E ❍ Not approved for use in hazardous locations. ◆ Add following suffix for complete catalog #: “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or “BES” for Bottom Exit connectors with 2˝ O.C. screw studs. rAdd “ME” suffix for Mult-E Kit. For Distribution only. µ Add “B” for Bottom Exit or “S” for Side Exit or “BS” for Bottom Exit with 2” O.C. screw studs. are available in white (001) or black (000) cans, excpet CBT’s, which are all in white cans. All ballasts are UL listed, CSA approved See pages 4-21 and 4-22 for Dimensions and Wiring Diagrams. FOR MORE INFORMATION CALL PAGE 4-18 1-800-BALLAST (225-5278) ELECTRONIC LONG TWIN T5 BALLASTS LONG TWIN T5 LAMPS • Ideal for track light & surface mount fixtures • New electronic 1 & 2 lamp models for 24 watt lamps • Electronic models feature universal input voltage from 120V to 277V. 347V models are also available. • Electronic models feature programmed rapid start for excellent lamp performance & auto reset shutdown circuit 36/39 AND 40 WATTS (BIAX, DULUX L AND PLL) 36/39 & 40 WATTS QUICK REFERENCE Lead Configuration Mag Qty Line Starting Min or of Line Catalog Input Current Current Ballast Start Power Bottom Bottom Starting Wir Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD Side Exit Exit Studs Method✿ Dim Diag Lamp Type Electrical Characteristics - 60 Hz 36/39 Watts 120 0.30 —— ❍ E 1 B224PUNV-C• 36 0.95 0° F High <10% X PRS -C 29 — — FT36W/2G11/RS 277 0.13 —— 120 71 0.59 —— ❍ E 2 B239PUNV-D• 0.97 0° F High <10% X PRS -D 29 — — 277 70 0.26 —— 120 0.37 ❍ E 1 B254PUNV-D£ 44 —— 1.22 0° F High <10% X — — PRS -D 28 277 0.17 Long Twin T5, ❍ 120 90 0.75 E 2 B254PUNV-D —— 1.20 0° F High <10% X — — PRS -D 23 4-Pin 277 88 0.32 120 0.29 < 10% ❍ E 1 C242UNV◆ 34 —— 0.88 0° F High X X X PRS C11 20 277 0.14 < 20% 120 ◆ 0.43 —— E 2 C242UNV• 64 0.83 0° F High <10% X X X PRS C11 20 277 0.19 —— ◆ E 2 347 C242/347• 64 0.19 —— 0.90 0° F High <10% X X X PRS C11 20 Nominal lamp watts and configuration Lamp Type 36/39 Watts CFM36W/2G10 T5 F-Lamp, 4-Pin E 1 E 1 E 1 E 2 ❍ E ❍ E 120 C240SI120RH 40 277 C240SI277RH 40 120 41 C240PUNVHP-B• 277 40 120 93 ◆ C242UNV 277 87 120 C340SI120RH 75 277 C340SI277RH 75 120 C240SI120RH 67 277 C240SI277RH 67 76 120 C240PUNVHP-B• 277 73 120 ◆ C242UNV 47 277 120 C340SI120RH 98 277 C340SI277RH 98 0.28 0.12 0.27 0.12 0.28 0.14 0.57 0.25 —— 0.95 0° F High <10% X — — PRS -C 29 —— 0.98 0° F High <10% X X X PRS C10 21 —— —— 0.98 0° F High <15% X X X PRS C11 20 —— —— 0.90 0° F High <10% X X X PRS C11 20 0.40 —— 1.02 50° F High <20% X — — IS C6 12✛ 0.17 —— 1.02 50° F High <20% X — — IS C6 12✛ 0.34 —— 1.00 0° F High <10% X — — PRS -B 20 0.15 0.78 —— 1.00 0° F High <10% X X X PRS C11 20 0.34 0.68 —— 0.99 50° F High <20% X — — IS C6 14 ✛ 0.30 —— 0.99 50° F High <20% X — — IS C6 14✛ 0.61 —— 0.88 50°F High <20% X — — IS C6 12 0.27 —— 0.88 50°F High <20% X — — IS C6 12 0.63 —— 0.90 0° F High <10% X — — PRS -B 20 0.27 0.40 —— 1.08 0° F High <10% X X X PRS C11 20 0.18 0.88 —— 0.88 50° F High <20% X — — IS C6 14 0.39 —— 0.88 50° F High <20% X — — IS C6 14 ✿ PRS = Programmed Rapid Start; IS = Instant Start ◆ Add following suffix for complete catalog #: “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or “BES” for Bottom Exit connectors with 2˝ O.C. screw studs. ❍ Not approved for use in hazardous locations. £Consult lamp manufacturers for applications with Ballast Factor >1.20. rAdd “ME” suffix for Mult-E Kit. For Distribution only. The encased ballasts listed on this page are available in white (001) or black (000) cans. All ballasts are UL listed, CSA approved See pages 4-21 and 4-22 for Dimensions and Wiring Diagrams. FOR MORE INFORMATION CALL PAGE 4-19 1-800-BALLAST (225-5278) Compact Fluorescent 1 1 E 1 E 2 ❍ E 2 Long Twin T5, ❍ E 2 4-Pin 2 ❍ E 2 ❍ E E 2 E 1 3 ❍ E 3 ❍ E Lamp Type 40 Watts FT40W/2G11 120 B224PUNV-C• 34 277 120 C2642UNV◆r 32 277 120 C242UNV◆ 33 277 120 68 C242UNV•◆r 277 67 ELECTRONIC LONG TWIN T5 LAMPS • Ideal for track light & recessed fixtures • Electronic models for 1, 2, 3 & 4 lamp applications • Programmed Rapid & Instant Starting Options • Models feature auto reset shutdown circuit 50, 55 & 80 WATTS ELECTRONIC LONG TWIN T5 BALLASTS 50, 55 AND 80 WATTS (BIAX, DULUX L AND PLL) QUICK REFERENCE Lead Configuration Mag Qty Line Starting Min or of Line Catalog Input Current Current Ballast Start Power Side Bottom Bottom Starting Wir Elec Lamps Volt Number Watts Amps Amps Factor Temp Factor THD Exit Exit Exit Studs Method_ Dim Diag Electrical Characteristics - 60 Hz Lamp Type 120 60 0.50 50 Watts m E 1 B254PUNV-D —— 1.12 0° F High <10% X — — PRS -D 29 277 59 0.22 FT50W/2G11 120 112 1.00 m E 2 B254PUNV-D —— 1.10 0° F High <10% X — — PRS -D 29 277 109 0.43 m E 1 347 B254P347-D 58 0.17 —— 1.12 0° F High <10% X — — PRS -D 27 m E 2 347 B254P347-D 106 0.31 —— 1.10 0° F High <10% X — — PRS -D 27 347 0.19 <10% Long Twin T5, E 1 B254PHRVHB-E 65 —— 1.12 0° F High X — — PRS -E 42 480 0.15 <15% 4-Pin 347 115 0.33 E 2 B254PHRVHB-E —— 1.10 0° F High <10% X — — PRS -E 41 480 114 0.25 120 180 1.51 E 3 B454PUNV-E —— 1.13 0° F High <10% X — — PRS -E 44 277 178 0.65 120 233 1.87 E 4 B454PUNV-E —— 1.10 0° F High <10% X — — PRS -E 44 277 225 0.80 120 240 1.98 E 4 B454PUNVHB-E —— 1.10 0° F High <10% X — — PRS -E 44 277 235 0.84 Nominal lamp watts and configuration Lamp Type 55 Watts FT55W/2G11 Compact Fluorescent Long Twin T5, 4-Pin Lamp Type 80 Watts FT80W/2G11 E 1 E 2 E 1 E 2 E 1 E 1 E 1 E 2 E 3 E 4 E 4 120 B254PUNV-D 58 277 120 112 B254PUNV-D 109 277 347 B254P347-D 57 347 B254P347-D 102 120 C242UNVu 46 277 347 C242/347u 43 347 B254PHRVHB-E 61 480 347 109 B254PHRVHB-E 108 480 120 170 B454PUNV-E 167 277 120 223 B454PUNV-E 217 277 120 229 B454PUNVHB-E 223 277 0.48 — — PRS -D 29 0.22 —— 0.92 0° F High <10% X 0.93 — — PRS -D 29 0.40 —— 0.90 0° F High <10% X 0.17 —— 0.92 0° F High <10% X — — PRS -D 27 0.30 —— 0.90 0° F High <10% X — — PRS -D 27 0.38 —— 0.83 0° F High <10% X X X PRS C11 21 0.17 0.13 —— 0.83 0° F High <10% X X X PRS C11 21 0.19 <10% —— 0.92 0° F High X — — PRS -E 42 0.14 <15% 0.33 — — PRS -E 41 0.24 —— 0.90 0° F High <10% X 1.42 — — PRS -E 44 0.62 —— 0.93 0° F High <10% X 1.87 — — PRS -E 44 0.80 —— 0.90 0° F High <10% X 1.91 — — PRS -E 44 0.80 —— 0.90 0° F High <10% X E 1 120 ES4515K 277 0.74 0.32 88 87 —— 1.00 0° F High <10% X — — PRS ESK 43 Long Twin T5, 4-Pin The encased ballasts listed on this page are available in white (001) or black (000) cans. All ballasts are UL listed, CSA _ IS = Instant Start; PRS = Programmed Rapid Start approved and designated Class P (thermally protected). u Add following suffix for complete catalog #: “SE” for Side Exit connectors or “BE” suffix for Bottom Exit connectors or “BES” for Bottom Exit connectors with 2˝ O.C. screw studs. m Not approved for use in hazardous locations. See pages 4-21 and 4-22 for Dimensions and Wiring Diagrams. FOR MORE INFORMATION CALL PAGE 4-20 1-800-BALLAST (225-5278) MAGNETIC AND ELECTRONIC COMPACT FLUORESCENT BALLASTS LONG TWIN T5 LAMPS DIMENSIONS REFERENCE Drawing for -B REFERENCE Drawing for C6 E D C A B Dwg. -B L W H M X 9.50” 1.50” 1.00” 8.89” 0.88” Dwg. C6 111/16" F 5/16" A B C D 2.40” 1.55” 8.31” 8.89” E F 9.50” 1.19” Lead Lengths: Side • Black/White–11˝ • Red/Blue–16˝ • Yellow–16˝ REFERENCE Drawing for C10 C REFERENCE Drawing for C11 F A G B D E Dwg. A B C D E F G Dwg. C10 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00” A B C D E F G C11 2.98” 1.00” 4.25” 4.61” 4.94” 1.56” 1.00” Leadless-Poke-in wire connection Leadless-Poke-in wire connection REFERENCE Drawing for CBT REFERENCE Drawing for -D, -E, ESK L W H M -D 16.88” 1.18” 1.00” 16.20” -E 16.88” 1.74” 1.18” 16.28” ESK 16.65” 1.24” 1.00” 16.30” Dwg. A B C D E CBT 3.86” 2.00” 1.00” 3.50” —— PAGE 4-21 X ------- Compact Fluorescent Dwg. MAGNETIC AND ELECTRONIC COMPACT FLUORESCENT BALLASTS LONG TWIN T5 LAMPS WIRING DIAGRAMS Black Red White Red BALLAST Yellow Blue Yellow Blue Black White Green Red BALLAST Yellow Blue DIAGRAM 23 Series lamp operation Line DIAGRAM 34 Line Black White DIAGRAM 27 Series lamp operation Blue Blue Red BALLAST Black White Green DIAGRAM 12 Parallel lamp operation Black White Line BALLAST DIAGRAM 42 For one lamp application, individually cap yellow and yellow/black leads, insulate to 600V DIAGRAM 5 Parallel lamp operation Red BALLAST Blue DIAGRAM 47 DIAGRAM 41 DIAGRAM 28 Blue Blue Blue Red DIAGRAM 43 DIAGRAM 29 DIAGRAM 14 Parallel lamp operation Cap unused blue lead; insulate to 600 Compact Fluorescent ; Black Red White Green Red BALLAST Yellow Yellow Blue Blue DIAGRAM 44 DIAGRAM 20 Series lamp operation Red Black White Green Red BALLAST Blue Blue Line DIAGRAM 33 Mount lamp within 1" of grounded metal reflector. DIAGRAM 21 FOR MORE INFORMATION CALL PAGE 4-22 1-800-BALLAST (225-5278) Ballasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies (“Universal”) offers a wide array of ballasts for High Intensity Discharge (HID) lamps. Applications include Metal Halide (MH), Pulse Start Metal Halide (PSMH), and High Pressure Sodium (HPS) lamps ranging from 35 to 1500 watts. We’re the technology leader in every category of HID ballasts. Our Universal Precise™ line is the latest innovation in magnetic core & coil technology in years. HID Universal offers a complete line of HID ballasts for applications ranging from 35 - 1500 watts. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group HID Notes PAGE 5-2 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Product Overview Core & Coil Core & coil ballasts are used in over 90% of all HID fixtures. Universal’s core & coil models are available for all HID lamp types, including single-, dual-, tri-, quad- and multi-volt designs. For added versatility and reduced inventory costs, Universal has also introduced the industry’s first Multi-5™ ballast (120, 208, 240, 277, or 480 volt), featuring a 480-volt tap on a conventional quad-tap ballast. Our core & coil models are ideal for a wide variety of lighting applications, including factories, warehouses, gymnasiums and retail stores. All these ballasts feature precision-wound coils, ensuring even heat dissipation and the highest electrical integrity. Universal’s Universal Precise™ is the next generation in core & coil technology, featuring a smaller, lightweight design and improved temperature performance. Universal Precise™ fits virtually all applications, and has no exposed live metal parts. There are no plastic extrusions, which prevents breakage during shipping. Color-coded leads make installation easy. 50 Hertz Universal offers 50 Hz core & coil ballasts to meet the rapid growth in demand in international markets. Our ballasts are available for 220, 230, and 240 volt electrical systems. F-Can These ballasts are used primarily for indoor downlighting applications where quiet operation is essential. All the components of these ballasts are enclosed in a fluorescent-style ballast can and are thermally protected. HID F-Can Ballasts Core and Coil Ballasts PAGE 5-3 HID Ballast Kits FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Product Overview For maximum safety and reliability, all Universal capacitors come with built-in bleed resistors (patented by Universal) and approved by CSA (CSA file #LR51331, metal cases only). Environmental safety is assured by use of biodegradable, nontoxic (no PCBs) dielectric fluid (soybean oil), patented by Universal for use in capacitors. Dry-film capacitors do not include protective devices. Since they can fail in a hazardous manner, it is the responsibility of the purchaser to take appropriate precautions. Capacitors Universal has a comprehensive line of capacitors in metal cases (up to 525V ratings) and plastic cases (up to 400V ratings). All Universal capacitors are designed for 60,000 hours of continuous life. They’re exceptionally reliable because we put them through accelerated life testing at 125% rated voltage and rated temperature +10°C. Universal capacitors are normally packaged with ballasts. They may also be ordered separately, bulk packaged, or individually boxed with the suffix “BH” (metal cases only). Capacitor weights vary from 1/4 lb. to 1 lb. each. Dry Capacitors Type “P” plastic case capacitors described in this section are dry and do NOT contain safety interrupters (or oil). Plastic cases are UL rated “94V-O” (for use up to 100°C maximum). Type “P” capacitors are supplied with stranded copper wire leads 8 inches long (18 awg, with 150°C rated insulation). Capacitor rolls are sealed inside plastic cases using epoxy. Design and testing of Universal capacitors follow specifications in Electronic Industries Association (EIA) Standard 456-A, titled “Metalized Film Dielectric Capacitors for Alternating Current Application.” “P” capacitors are designed and rated for continuous duty AC voltages below 400VAC @ 50 or 60 Hz. Capacitors used with HID ballasts at voltages above 400VAC should contain interrupters (available from Universal in oval “MF” and round “RMF” oil-filled metal cases). Metal and Oil Filled Capacitors HID Plastic Dry Type Capacitors Protective Device (Only in metal cases) Protective device to prevent case rupture Normal Cover Position Normal Cover Position 1/2" 1/2" Barrier Normal Position of Protective Device Barrier Barrier Position of Protective Device After Activation Capacitor Protective CapacitorDevices Protective Devices PAGE 5-4 Barrier FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Oil-Filled Capacitors µF VACr 5.0 300 6.0 Part # Case Ht (“) µF VACr Part # Case Ht (“) 005-1466-BH 1.25 oval 2.2 24.0 480 005-2779-BH 1.75 oval 3.9 300 005-1561-BH 1.25 oval 2.2 24.5 300 005-3278-BH 1.75 oval 2.7 7.0 300 005-1410-BH 1.25 oval 2.2 26.0 330 005-2669-BH 1.75 oval 3.1 8.0 330 005-1411-BH 1.25 oval 2.2 26.0 525 0052776-BH 1.75 oval 4.3 10.0 330 005-1413-BH 1.25 oval 2.7 28.0 240 005-1886-BH 1.75 dia 2.3 10.0 400 005-2666-BH 1.25 oval 3.9 28.0 300 005-1468-BH 1.75 oval 3.1 10.0 400 005-1184-BH 1.50 oval 2.7 28.0 425 005-1799-BH 1.75 oval 3.9 10.0 400 005-2167-BH 1.75 dia 2.9 30.0 440 005-1475-BH 1.75 oval 3.9 12.0 300 005-1467-BH 1.25 oval 3.1 32.0 300 005-2351-BH 1.75 oval 3.1 12.0 400 005-2799-BH 1.50 oval 2.7 32.0 525 005-1474-BH 2.00 oval 3.9 12.0 440 005-1464-BH 1.50 oval 3.1 33.0 300 005-1470-BH 1.75 oval 3.1 13.0 300 005-1414-BH 1.25 oval 3.1 35.0 330 005-1421-BH 1.75 oval 3.1 14.0 240 005-1884-BH 1.75 dia 2.3 36.0 525 005-2793-BH 2.00 oval 4.3 14.0 300 005-1415-BH 1.50 oval 2.7 40.0 240 005-1887-BH 1.75 dia 2.7 15.0 400 005-1185-BH 1.75 oval 2.7 40.0 300 005-1768-BH 1.75 oval 3.9 16.0 300 005-1498-BH 1.50 oval 2.7 48.0 330 005-1422-BH 1.75 oval 3.9 17.5 300 005-1417-BH 1.50 oval 3.1 52.0 240 005-1888-BH 2.00 dia 2.9 18.0 440 005-1401-BH 1.75 oval 3.1 55.0 240 005-1594-BH 1.75 oval 3.5 18.5 330 005-1796-BH 1.50 oval 3.1 55.0 300 005-2117-BH 1.75 oval 3.9 20.0 240 005-1885-BH 1.75 dia 2.3 20.0 330 005-1418-BH 1.50 oval 3.1 20.5 400 005-3262-BH 1.75 oval 3.1 21.0 525 005-1495-BH 1.75 oval 3.9 22.5 300 005-1419-BH 1.50 oval 3.5 24.0 360 005-3160-BH 1.75 oval 3.1 24.0 400 005-2664-BH 1.75 oval 3.1 HID PAGE 5-5 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID Notes PAGE 5-2 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Dry Capacitors -- µF V 100°C Rated Part # DIA (“) L (“) 105°C Rated Part # DIA (“) L (“) 280 005-4400-BH 1.18 2.20 R17058511-BH 1.26 2.36 280 005-4051-BH 1.18 2.76 R17058512-BH 1.26 2.83 330 R17058539-BH 1.26 2.24 280 R17058513-BH 1.26 2.36 280 005-4052-BH 1.18 2.76 R17058514-BH 1.26 2.83 280 005-4053-BH 1.58 2.76 R17058515-BH 1.65 2.83 300 005-4054-BH 1.58 2.76 R17058535-BH 1.65 2.83 330 R17058541-BH 1.65 2.83 280 005-4407-BH 1.18 2.76 R17058517-BH 1.26 2.83 280 005-4056-BH 1.58 2.76 R17058519-BH 1.65 2.83 R17058226-BH 1.65 330 005-4408-BH 1.58 2.76 R17058578-BH 1.65 2.83 R17058227-BH 1.65 400 005-4409-BH 1.58 2.76 R17058555-BH 1.65 2.83 400 005-4025-BH 1.58 3.74 R17058557-BH 1.65 3.82 R17058310-BH 1.65 400 005-4485-BH 1.58 2.76 R17058558-BH 1.65 2.83 300 005-4099-BH 1.58 2.76 R17058536-BH 1.65 2.83 330 005-4411-BH 1.58 2.76 R17058543-BH 1.65 2.83 400 005-4412-BH 1.58 3.74 R17058580-BH 1.65 3.82 330 005-4044-BH 1.58 3.74 170 R17058500-BH 1.26 2.83 280 005-4060-BH 1.58 2.76 R17058520-BH 1.65 2.83 280 005-4416-BH 1.58 2.76 R17058520-BH 1.65 2.83 R17058232-BH 1.65 400 005-4164-BH 1.58 3.74 R17058560-BH 1.65 3.82 400 R17058562-BH 1.65 3.82 400 005-4026-BH 1.77 3.74 R17058563-BH 1.85 3.82 R17058320-BH 1.85 280 005-4062-BH 1.58 2.76 R17058522-BH 1.65 2.83 280 005-4420-BH 1.58 2.76 R17058522-BH 1.65 2.83 330 R17058547-BH 1.65 2.83 400 R17058588-BH 1.65 3.82 280 R17058523-BH 1.65 3.82 170 005-4065-BH 1.58 2.76 R17058501-BH 1.65 2.83 280 005-4066-BH 1.58 3.74 R17058526-BH 1.65 3.82 330 400 R17058564-BH 1.85 3.82 400 005-4432-BH 1.77 3.74 R17058565-BH 1.85 3.82 400 005-4128-BH 1.77 3.74 R17058567-BH 1.85 3.82 400 005-4483-BH 1.77 3.74 R17058569-BH 1.85 3.82 280 R17058527-BH 1.65 3.15 280 R17058528-BH 1.65 3.82 280 R17058529-BH 1.65 3.82 400 005-4438-BH 1.85 3.74 R17058571-BH 1.85 3.82 R17058342-BH 1.85 400 005-4027-BH 1.77 4.61 330 005-4047-BH 1.58 4.61 R17058552-BH 1.65 4.76 300 005-4048-BH 1.58 4.61 R17058537-BH 1.65 4.76 400 005-4484-BH 1.77 4.61 R17058574-BH 1.85 4.76 170 005-4071-BH 1.58 2.76 R17058502-BH 1.65 2.83 280 005-4072-BH 1.58 4.61 R17058530-BH 1.65 4.76 330 005-4447-BH 1.77 3.74 8R17058553-BH 1.85 3.82 2.83 2.83 3.82 2.83 3.82 5.31 FOR MORE INFORMATION CALL PAGE 5-7 1-800-BALLAST (225-5278) HID 5.0 5.0 5.0 6.0 6.0 7.0 8.0 8.0 10.0 10.0 10.0 10.0 10.0 11.0 12.0 12.0 12.0 13.0 14.0 14.0 14.0 14.0 15.0 15.0 16.0 16.0 16.0 17.0 17.5 20.0 20.0 20.0 20.0 20.5 21.0 22.0 22.5 22.5 24.0 24.0 24.0 24.5 26.0 26.5 28.0 28.0 28.0 90°C Rated Part # DIA (“) L (“) Dry Capacitors (Cont.) µF V 35.0 35.0 40.0 40.0 48.0 48.0 52.0 52.0 55.0 55.0 55.0 90°C Rated Part # DIA (“) L (“) 100°C Rated Part # DIA (“) L (“) 280 280 005-4075-P 1.77 4.61 240 005-4456-P 1.58 3.74 240 005-4077-P 1.58 4.61 280 330 170 005-4087-P 1.77 3.74 280 005-4127-P 1.77 4.61 240 005-4465-P 1.77 3.74 240 005-4084-P 1.77 4.61 300 R17058531-BH 1.65 R17058532-BH 1.85 R17058505-BH 1.65 R17058506-BH 1.65 R17058533-BH 1.85 R17058554-BH 2.05 R17058503-BH 1.85 R17058534-BH 1.85 R17058507-BH 1.85 R17058509-BH 1.85 R17058538-BH 1.85 105°C Rated Part # DIA (“) L (“) 3.82 4.76 3.82 4.76 4.76 4.76 3.82 4.76 3.82 R17058212-BH 1.85 4.76 4.76 5.31 HT HID Ballasts Designed for high temperature applications Includes 105º Capacitors and Ignitors Voltage Catalog Number Carton Pack Metal Halide 175W Quad-Tap M175MLTAC3M 818C HID Lamp Wattage 175W Multi-5 M175ML5AC3M 818C 175W 480V M17548TAC3M 818C 175W Tri-Tap M175TRIAC30 818C 250W Quad-Tap M250MLTAC3M 818C 250W Quad-Tap M250MLTAC4M 818C 250W Multi-5 M250ML5AC3M 818C 250W Multi-5 M250ML5AC4M 250W 480V M25048TAC3M 818C 250W 480V M25048TAC4M 818C 400W Quad-Tap M400MLTAC4M 818C 400W Multi-5 M400ML5AC4M 818C 400W 480V M40048TAC4M 818C 400W Tri-Tap M400TRIAC4M 818C Lamp Wattage Voltage Catalog Number Carton Pack Pulse Start Metal Halide 175W Quad-Tap P175MLTAC3M 818C Kit 818K 175W Multi-5 P175ML5AC3M 400W Quad-Tap P400MLTAC4M 818C 400W Multi-5 P400ML5AC4M 818K 818K High Pressure Sodium 818K 818K 818K Refer to catalog pages for ballast dimensions and electrical data Quad-Tap: 120/208/240/277 Volt Multi-5: 120/208/240/277/480 Volt Tri-Trap: 120/277/347 480V include 120V tap for stand-by lighting Kit 100W Quad-Tap S100MLTLC3M 818C 100W 480V S10048TLC3M 818C 150W Quad-Tap S150MLTLC3M 818C 150W 480V S15048TLC3M 818C 150W Tri-Trap S150TRILC3M 818C 250W Multi-5 S250ML5AC4M 400W Quad-Tap S400MLTAC4M 818C 400W Multi-5 S400ML5AC4M 818C 400W Multi-5 S400ML5AC5M 400W 480V S40048TAC4M 818C 818K 818K 818K 818K 818K FOR MORE INFORMATION CALL PAGE 5-8 1-800-BALLAST (225-5278) 5.75" Slot aces 7.75" 2.75" Bracket Reference Chart .281 Slot 6 Req. 1.75" on center 7.75" Bracket B4 0.50" TYP. CORE & COIL WELDED BRACKETS CORE & COIL ADJUSTABLE MOUNTING Bracket B4 B R A C K E T S 6.10" on center 0.55" 6.75" 0.50" 5.75" on center .640" 7.75" 7.75" BracketAll welded B3brackets are .093” thick. Ref. Drawing B2 Ref. Drawing B1 0.2 3 Routinely supplied with replacement kits. 0.75"0.25" .250 Slot 2 Places 0.75"0.25" Ref. Drawing ADJ1 .250 Slot 2 Places 1.25" 1.00" 0.75"0.25" 0.75"0.25" 3.35" 0.75"0.25" 1.25" 1.00" 0.30" 3.35" 4.00" 30" 3.35" 5.25" 0.30" Bracket B2 Bracket B1-A .281 Slot 6 Req. .281 Slot 2 Places 0.75"0.25" .250 Slot 2 Places 1.25" 2.65" 6.75" 3.35" Bracket B1 on center 4.00" 7.75" 0.55" 0.30" 4.60" .640"0.50" 7.75" BracketB1-A B4 Bracket Bracket B3 Ref. Drawing B4 2.75" R. TYP. .281 Slot 6 Req. 0.70" 2.65" 6.10" 4.60" on center 5.25" 0.25" Dia. 3 Holes 0.50" R. TYP. 6.10" on center 0.55" .640" Bracket B2 B4 Bracket .281 Slot 6 Req. 0.50" TYP. 7.75" R. TYP. 0.50" 45º 2.65" 0.58" .29" 1.50" 0.90" 0.70" 6.10" 0.25" Dia. 2 0.55" Holes 6.75" on center 1.50" For use with: 7.75" 6.10" 0.50" Bracket B3 Bracket B1-B Bracket B4 Bracket B4 .640" 7.75" OR .640" 0.25" Dia. 3 Holes • 50 to 175 watt Mercury, High Pressure Sodium and Metal Halide and some 250 watt Metal Halide on center 0.55" 0.93" 0.70" 0.70" on center 0.70" 7.75" 4.60" 6.75" on center 5.25" 3 Holes 0.29" R. TYP. on center 0.25" Dia. 1.30" 1.75" 0.93" 0.50" 1.00" 1.75" 2.75"0.25" 0.09" 0.43" 7.75" 1.25" 1.50" Bracket B2 B4 Bracket 5.50" 6.75" on center 1.81" 2.65" on center 7.75" on center .281 Slot 6 Req. 0.70" 5.25" 6.75" Ref. Drawing MB1 1.75" TYP. .281 Slot 6 Req. 1.75" on center TYP. Bracket B1-A Bracket B3 4.00" 7.75" 7.75" Ref. Drawing B1-B 1.50" 0.30" 7.75" TYP. on center 1.25" 1.00" 2.75" 0.50" 3.35" 0.50" Bracket B2 2 Places 0.70" on center 6.10" .281 Slot 2 Places Ref. Drawing ADJ2.250 Slot OR 1.25" 1.00" 0.70" 2.75" 1.75" 0.30" R. TYP. 4.00" 0.50" Bracket B1-A 5.25" Ref. Drawing B3 0.75"0.25" 0.50" TYP. 1.25" 4.60" 0.30" 4.00" Bracket B1-A Bracket B1 .281 Slot 2.75" 1.75" 2 Places on center 0.75"0.25" 3.35" 3.35" Bracket B1 4.00" Ref. Drawing B1-A 0.30" OR 4.00" 4.60" 0.30" 4.00"3.35" 0.30" 0.70" R. TYP. Bracket B3 0.70 2.65" 0.25" Dia. 3 Holes OR Ref. Drawing MB2 OR 7.25" 1.880" .090" .460" 1.300" 2.685" 1.750" 45ϒ .290" .930" .580" .290" .735" 1/4" OR Dia. 2 Holes For use with: • 250 to 1500 watt Metal Halide • 250 to 1000 watt High Pressure Sodium and Mercury Vapor OR PAGE 5-9 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID .835" Application And Operating Information Underwriters’ Laboratories, Inc. Acceptance All F-Can and Weatherproof ballasts listed in this catalog are Underwriters’ Laboratories, Inc. white card listed, except those for 347 volt operation. All Core & Coil and Potted Core & Coil ballasts listed in this catalog are Underwriters’ Laboratories, Inc. yellow card listed (component recognized). temperature. The ballast will continue to cycle until the cause of overheating is eliminated. If the ballast is defective, it must be replaced. If the cause is external, the ballast will resume normal operation after abnormal conditions are eliminated. To attain normal ballast life, the maximum coil temperature of the ballast should not exceed the rating of the insulation system. A temperature increase of 10° C results in a 50% reduction of ballast life. Ballast Replacement Ballast replacement presents the possibility of exposure to potentially hazardous voltages and should be performed only by qualified personnel. All installation, inspection and maintenance should be performed only with the entire circuit power to fixture or equipment turned off. Installation shall be in accordance with National Electric Code. Low Ambient Temperature (cold) As temperatures drop, less and less vaporized gas is available within the arc tube of a high intensity discharge lamp, thereby causing an increase in the open circuit voltage required to initiate an arc in the lamp, until a point is reached where the lamp cannot be started. The minimum temperature at which any ballast listed in this catalog will provide reliable starting is listed with the electrical characteristics. Heat A ballast, like any other electrical device, generates heat during normal operation. Planning for maximum heat dissipation with proper fixture design, installation planning and ballast selection will minimize the possibility of a heat-related problem arising. Excessive temperature will have an adverse effect on ballast life. Normal temperature limits: F-Can Ballasts Maximum case temperature: 90°C Potted Core & Coil Ballasts and Core & Coil Ballasts Insulation: Class 180°C Maximum coil temperature: 165°C (measured by change of resistance method) Ballasts should be protected from weather, moisture, or other abnormal atmospheric conditions, unless specifically designed for use under adverse conditions. Fusing The purpose of fusing an HID ballast is to remove the ballast from the power line in the event of a ballast system failure. A fuse does not protect the ballast from failing. Because the temperature in the ballast compartment is high, typically 90OC, fuse ratings are specified at 25OC, and that this rating declines as the temperature increases, HID fuse recommendations are made between 2 and 3 times the maximum current the ballast will draw during all normal conditions. HID All F-Can ballasts listed in this catalog are equipped with built-in automatic resetting internal thermal protection as a standard feature. Fast-blow fuses should not be used due to the possibility of high inrush currents. These currents are due to the fact that the power can be applied ant any point in the AC voltage waveform. Standard and slow-blow are acceptable. Whenever a ballast with thermal protection is used, it is imperative that the fixture/ballast/lamp combination be heat tested under actual or simulated installation conditions to assure that the ballast will not cycle. The resetting thermal protector functions as a thermostat which will open and temporarily deactivate the ballast when it exceeds the permissible When using the 120V tap for auxiliary lighting, a slowblow fuse should be used to protect the ballast from damage from a fault in the auxiliary lighting circuit. REMOTE MOUNTING DISTANCE Maximum Length in Feet for Remote Mounting of HID Ballasts to Lamp ANSI Lamp Type Watts 12 GA 14 GA 16 GA 18 GA M57 M58 M59 M47 M48 Metal Halide Metal Halide Metal Halide Metal Halide Metal Halide 175 250 400 1000 1500 272 194 132 196 146 171 122 83 123 92 107 77 52 77 58 67 48 33 48 36 For proper installation, insure that remote ballasts are properly vented and mounted to a heat-dissipating surface. PAGE 5-10 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Application And Operating Information Sound High intensity discharge lamp ballasts, like all electromagnetic devices, produce noise, or “hum.” It is the degree of noise which determines the existence of a problem. Ballast noise will only be noticeable when it exceeds the ambient sound level of the installation. It is obvious that a ballast designed primarily for outdoor or factory use would not be suitable in an office environment. The vast improvements in all high intensity discharge lamps and ballasts, and their excellent energy efficiency, have made them viable options for many indoor applications. The ballasts being considered should be carefully analyzed to insure that there will not be an objectionable level of ballast noise. All F-Can ballasts listed in this catalog are “Sound Rated” to aid in the selection of a ballast which is proper for the environment in which it will operate. Potted Core & Coil ballasts are also designed to operate at reduced sound levels, generally several decibels lower than a standard Core & Coil ballast. Core & Coil ballasts are not sound rated. In situations where light output necessitates using a ballast with a sound rating or noise level not normally acceptable, the ballast should be remotely mounted. Note, however, that not all ballasts listed in this catalog are designed or recommended for remote mounting. Polarity Polarity refers to the proper connection of ballast lead wires to line wires. To aid you in making a correct installation, Universal ballast leads are color-coded for easy identification. The white or yellow ballast lead is to be connected to the neutral or common. Choose the appropriate ballast voltage lead to connect to the line. Operating Line Voltage Limits To receive the full benefits of rated lamp output and to prolong ballast life, it is essential that the voltage supplied to an installation be maintained within the prescribed limits. In general, the line voltage supplied to a lag type ballast (reactor or high reactance autotransformer) should be maintained within 5% of the voltage for which the ballast is rated. The line voltage to lead type ballasts (constant wattage autotransformer or constant wattage isolated) should be maintained within 10%. Subjecting a ballast to excessive voltage for an extended period of time results in the deterioration of the coil insulation. This insulation breakdown will cause early ballast failure. Low voltage has no damaging effect on the ballast. It could, however, have an adverse effect on lamp performance and starting dependability. Maintenance Selecting and installing an adequate and efficient lighting system means nothing if it is not properly maintained. Maintenance must always be considered as part of the life cycle cost of any high intensity discharge lighting installation in order to assure the continued performance of the system as originally specified. First and foremost in importance is proper lamp maintenance. High intensity discharge lamps do not “burn out” like an incandescent bulb, but rather, undergo changes within the arc tube which prevent the lamp from starting properly, warming up and producing full light output. The beginning of difficulties such as these generally indicates the end of a lamp’s useful life. Also, a dead lamp left in a fixture can be very damaging to the ignitor in systems which utilize them. To overcome this problem, Universal offers automatic shutoff ignitors, which are described in the ignitor section of this catalog. PAGE 5-11 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID Grounding Ballasts and capacitors or starters in metallic casings must always be grounded. Ballasts and components may be grounded to the fixture or otherwise connected to ground. It would be hazardous to make contact with an ungrounded fixture, ballast or other electrical component while in operation. Application And Operating Information In difficult locations, group replacement of all the lamps, working or not, is often more economical and convenient than spot replacement. The same, of course, applies to ballasts which might be approaching the end of their life. Only you can decide what is right for your lighting system, but what is important is that you have a maintenance program. Periodic cleaning of the fixtures’ lenses and reflectors is also important in maintaining proper light output. For indoor systems, maintenance of reflective surfaces, such as walls and ceilings, will also help assure proper levels of illumination. STANDBY LIGHTING AND PACKAGING Standby Lighting To provide light during a high intensity discharge lamp’s warmup period, or the cool-down period following a power interruption which has extinguished it, incandescent standby lighting can be incorporated. This is accomplished by use of a standby lighting device, or remote, that switches off an incandescent lamp incorporated into the fixture once an arc has been established, or reestablished, in the HID lamp. Generally, standby lighting devices operate on 120 volts, so a tap must be provided on ballasts designed to operate at higher line voltages. HID The 120 volt terminal or lead on all Universal dual-, tri-, quad- and multi-volt ballasts can be used as a tap for standby lighting when the ballast is utilized for any of the higher voltages. Many single voltage ballasts are available with a 120 volt tap and are listed throughout the Core & Coil data section. Other single voltage ballasts may be available in this version. Consult our Customer Service Department for availability and price information. Any connection to the 120 volt tap must be accomplished by means of a slow-blow fuse. This fuse will protect the ballast from abnormal conditions in the standby lamp circuit or its control device. The fuse should be located in the coolest place in the fixture (below 80°C). The recommended fuse amperage and maximum auxiliary lamp wattage are listed in this catalog for each ballast suitable for standby lighting applications. Be sure to follow the wiring instructions of the standby lighting device manufacturer. All applicable requirements of the National Electrical Code must be met. Packaging Standard Pack Universal’s high intensity discharge lamp ballasts are routinely packed in easy-to-handle cartons containing from 1 to 20 units per carton, depending on the size and weight of the ballasts. Consult Customer Service for the number of “units per carton” for shipment with attached mounting brackets, capacitors (for high power factor units), and ignitors (if required). Other ordering criteria may cause packaging to vary. Tray Pack For the convenience of large quantity users who request it, Universal ballasts may be packed in trays. The number of units depends upon the size and weight of each ballast. These trays are large corrugated cartons with lids and sides that come off easily. This type of packaging affords Universal customers a savings of time and money on their own production costs. There are fewer cartons to open, break up and dispose of on the assembly line; warehouse handling is reduced and inventory control is easier. There is no additional charge for tray packing. Individual Cartons All Distributor Replacement Kits, Weatherproof, Potted Core & Coil and other larger ballasts are packaged in individual cartons. Individual cartons serve a threefold purpose: as a display carton, a stock package, and a shipping container for the retail market. Individual cartons may be packed in master cartons, depending on weight and size. Individual carton packaging may be available for other ballasts. Contact our Customer Service Department for availability and cost. PAGE 5-12 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Nomenclature UNIVERSAL PRECISE™ ABBREVIATIONS UL Bench Top Rise Temperature Code CWA Constant Wattage Autotransformer CWI Constant Wattage Isolated ISO Regulated Lag R-HPF Reactor—High Power Factor R-NPF Reactor—Normal Power Factor To facilitate UL inspection, the UL Bench Top Rise Temperature Code is shown on the Universal Core & Coil Ballast label as 1029X. 1029 is the UL Standard for HID Ballasts, and the X is the temperature code. If a fixture is UL listed for 1029D, then automatically all ballasts with an A, B, C or D temperature classification are acceptable for use within that same fixture. HX-HPF Lag Type — High Reactance Autotransformer—High Power Factor UL Bench Top Rise Letter Code Temperature Range for Class H (180° C) Ballasts HX-NPF Lag Type — High Reactance Autotransformer—Normal Power Factor A<75°C B 75°C < 80°C C 80°C < 85°C D 85°C < 90°C E 90°C < 95°C F 95°C < 100°C Field 1 2 3 4 5 6 7 8 9 1 5 1 M 3 0 1 C Number of Digits 1 C 0 0 Container Type (C/T/I/K) Pack Code (000 TO 999) Field 1 A Socket Type & Other Oddities (M/D/X/L) Frame Size (E/3/4/5/X) Style (C/F/W/E/I/P) Circuit Type (R/A/I/O/L/M) 3 M L T Primary Voltage (MLT/ML5/TRI/ 48T/120/277/ 230) Lamp Type (M/P/S/H) 2 to 4 2 0 0 0 Wattage 1 M Description (M) Metal Halide, (P) Pulse Start Metal Halide, (S) High Pressure Sodium 2 35 to 2000 Watts (Varies from two to four digits) 3 (MLT) Quad, (ML5) Multi-5, (TRI) TriVolt, (48T) 480/120, (120) 120, (277) 277, (230) 230V/50Hz 4 (R) Reactor, (A) CWA, (I) CWI, (O) IsoReg, (L) High Reactance/Lag, (M) MagLag 5 (C), C&C, (F) F-Can, (W) Weatherproof, (E) Encased/Potted C&C (I) Indoor Encased 6 (E) E&I, (3) 3x4, (4) 4-3/4, (5) 5-3/4, (X) Non Core and Coil 7 (M) Mogul or Medium, (D) Double Ended, (X) Multiple Lamps, (L) Low Loss 8 Pack Code (000 to 999, per pack code listing) 9 (C) Carton, (T) Tray, (I) Individual, (K) Kit PAGE 5-13 HID 1 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Specifications TYPICAL SPECIFICATIONS FOR HID BALLASTS 1. Ballasts shall be designed in accordance with all applicable ANSI specifications including ANSI C82.4. 2 . The Core & Coil ballast shall be designed with class “H” (180°C) or higher insulation system and vacuum impregnated with a 100% solid based resin. 3 . All coils shall be precision wound. 4 . Core & Coil ballasts shall be designed to operate at least 180 cycles of 12 hours on and 12 hours off, with the lamp circuit in an open or short-circuited condition and without undue reduction in ballast life. 5. Core & Coil ballast and starter combinations shall be designed to provide a reliable lamp starting down to -40°C for High Pressure Sodium and Pulse Start Metal Halide and -30°C for Metal Halide and Mercury at minimum rated line voltage. 6. Manufacturer shall provide written warranty against defects in workmanship, including replacement, for two years from date of manufacture. CAPACITORS 1. All capacitors will be provided with a self-contained internal bleeder resistor. HID 2. All oil-filled capacitors will be housed in corrosion-resistant steel cans and contain .25” quick disconnect terminals. 3. All capacitors will be supplied by ballast manufacturer. IGNITORS 1. All ignitors will be epoxy-filled with either a plastic or aluminum external housing. 2. The ignitor shall be so designed to provide six months of lamp open circuit operation without failure. KITS 1. All HID kits shall be precision wound to insure proper insulation. 2. All HID kits shall be pre-wired. 3. All HID kits shall be built with color-coded leads. 4. All HID kits are to be UL and CSA recognized following the guidelines found in UL 1029 and CAN/CSA-22.2 No. 74-92 (part 2 and 3). 5. Universal Model __________________________ (or approved equal). PAGE 5-14 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Distributor Replacement Kits Universal’s HID distributor replacement kits contain the appropriate core & coil, a properly rated capacitor, and all other components required for ballast replacement. Our kits are the quickest and easiest to install of any on the market, thanks to unique design features like: • • • • • Prewired capacitor and ignitor (if required) to save installation time and reduce wiring errors. Color-coded leads to reduce risk of incorrect wiring inside the fixture. Features that exceed UL standards, including capacitors that offer trip fault protection. Simple installation instructions and troubleshooting tips. UPS shippable box. Our kit offerings include many quad voltage (120, 208, 240, or 277 volt) and 480 volt core & coil ballasts, as well as the new Multi-5 five-voltage ballast. 480 volt ballasts are equipped with a 120 volt tap to accommodate stand by lighting. Also available for Metal Halide and High Pressure Sodium applications, Universal Lighting’s Multi-5TM Ballast-Lamp Replacement Kit. This easy to carry convenient all-in-one kit ensures ballast lamp compatibility. Distributor replacement kit cartons are packaged in master cartons in quantities from 1 to 6 units. Master carton quantities can be found on Universal’s list and distributor price sheets. Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits LampType Wattage Voltage Frame Size Old Part Number 175 120/208/240/277 3 x 4 1130-91R-500K M175MLTAC3M500K 175 Multi-5™ Uni-Pak™ 3 x 4 New M175ML5AC3M555K 250 120/208/240/277 250 Multi-5™ Uni-Pak™ 250 120/208/240/277 175 175 Metal Halide 250 250 250 250 250 400 400 400 400 400 1000 1000 1000 1000 3 x 4 480-120 3 x 4 1130-31-500K 3 x 4 New Multi-5 480-120 Multi-5 1130-92-500K 3 x 4 New 3 x 4 4.25 x 4.75 4.25 x 4.75 1130-32-500K 1130-92R-500K New M175ML5AC3M500K M17548TAC3M500K M250MLTAC3M500K M250ML5AC3M500K M250ML5AC3M555K M25048TAC3M500K M250MLTAC4M500K M250ML5AC4M500K New M250ML5AC4M555K 4.25 x 4.75 1130-93U-500K M400MLTAC4M500K Multi-5 4.25 x 4.75 1130-826S-500K 480-120 4.25 x 4.75 1130-33R-500K 120/208/240/277 4.25 x 5.75 1130-97R-500K 480-120 120/208/240/277 120/208/240/277 4.25 x 4.75 4.25 x 4.75 Multi-5™ Uni-Pak™ 4.25 x 4.75 120/208/240/277 Multi-5 4.25 x 5.75 4.25 x 5.75 Multi-5™ Uni-Pak™ 4.25 x 5.75 480-120 1250 120/208/240/277 1500 480-120 1500 3 x 4 Multi-5™ Uni-Pak™ 4.25 x 4.75 New 120/208/240/277 4.25 x 5.75 4.25 x 5.75 4.25 x 5.75 4.25 x 5.75 1130-32R-500K 1130-93R-500K New 1130-97-500K New New 1130-57-500K New 1130-99R-500K 1130-69R-500K PAGE 5-15 M25048TAC4M500K M400MLTAC4M500K M400ML5AC4M500K M400ML5AC4M555K M40048TAC4M500K M1000MLTAC5M500K M1000MLTAC5M500K M1000ML5AC5M500K M1000ML5AC5M555K M100048TAC5M500K M1250MLTAC5M500K M1500MLTAC5M500K M150048TAC5M500K FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID 1000 Multi-5 New Part Number Distributor Replacement Kits Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits LampType Wattage Voltage Frame Size 35 120/208/240/277 3 x 4 70 120/208/240/277 3 x 4 70 100 120/208/240/277 100 Pulse Start 480-120 120/208/240/277 100 120/208/240/277 70 150 150 150 120/208/240/277 480-120 120/208/240/277 120/208/240/277 480-120 175 120/208/240/277 175 Multi-5 175 175 175 200 120/208/240/277 120/208/240/277 480-120 Multi-5 480-120 480-120 350 120/208/240/277 350 Multi-5 320 320 350 350 3 x 4 New 400 480-120 400 450 450 450 Multi-5 120/208/240/277 Multi-5 480-120 750 120/208/240/277 750 480-120 750 Multi-5 875 120/208/240/277 1000 Multi-5 1000 120/208/240/277 New 3 x 4 New 3 x 4 New 4.25 x 5.75 New 4.25 x 5.75 New 3 x 4 New New 4.25 x 4.75 4.25 x 4.75 New New New 4.25 x 4.75 1130-827-500K 4.25 x 4.75 New 4.25 x 4.75 1130-622-500K 4.25 x 4.75 New 4.25 x 4.75 480-120 New 3 x 4 480-120 120/208/240/277 New 11310-543-500K 3 x 4 4.25 x 4.75 400 New 3 x 4 Multi-5 Multi-5 M70MLTLC3M500K New New 4.25 x 4.75 250 11310-510-500K 3 x 4 Multi-5 Multi-5 M35MLTLC3M500K 11310-90-500K 3 x 4 4.25 x 4.75 4.25 x 4.75 New New 4.25 x 5.75 4.25 x 5.75 4.25 x 5.75 4.25 x 5.75 4.25 x 5.75 4.25 x 5.75 PAGE 5-16 M100MLTLC3M500K M100MLTLC3D500K M10048TLC3M500K M150MLTLC3M500K M150MLTLC3D500K M15048TLC3M500K P175MLTAC3M500K P175MLTAC3L500K P175ML5AC3M500K P175MLTAC4L500K P17548TAC4L500K P200ML5AC3M500K P250MLTAC4L500K P250ML5AC4M500K P250ML5AC4L500K P25048TAC4L500K P320MLTAC4O500K P32048TAC4L500K 4.25 x 4.75 4.25 x 4.75 M70MLTLC3D500K New 1130-829-500K 4.25 x 4.75 M7048TLC3M500K P320ML5AC4M500K New 4.25 x 4.75 M50MLTLC3M500K New 4.25 x 4.75 4.25 x 4.75 New Part Number New 11310-95-500K 3 x 4 250 250 320 3 x 4 4.25 x 4.75 3 x 4 120/208/240/277 120/208/240/277 3 x 4 250 320 Metal Halide HID 50 Old Part Number New New New New New New New New New New P32048TAC4M500K P350MLTAC4M500K P350ML5AC4M500K P350ML5AC4L500K P35048TAC4L500K P400MLTAC4L500K P400ML5AC4M500K P40048TAC4M500K P450MLTAC4M500K P450ML5AC4M500K P45048TAC4M500K P750MLTAC5M500K P750ML5AC5M500K P75048TAC5M500K P875MLTAC5M500K P1000MLTAC5M500K P1000ML5AC5M500K FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Distributor Replacement Kits Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits LampType Wattage Voltage Frame Size 50 120/208/240/277 3 x 4 70 70 120/208/240/277 480-120 Old Part Number New Part Number 12310-95-500K S50MLTLC3M500K 3 x 4 12310-148R-500K S7048TLC3M500K 3 x 4 12310-30R-500K S10048TLC3M500K 3 x 4 12310-160S-500K 4.25 x 4.75 New 3 x 4 12310-153-500K 100 120/208/240/277 3 x 4 150 120/208/240/277 3 x 4 200 120/208/240/277 4.25 x 4.75 250 Multi-5 4.25 x 4.75 H.P.S. 100 150 200 250 250 250 400 400 400 400 400 400 400 600 1000 1000 1000 1000 480-120 480-120 480-120 120/208/240/277 480-120 12310-90-500K 12310-165-500K 4.25 x 4.75 4.25 x 4.75 Multi-5™ Uni-Pak™ 4.25 x 4.75 Multi-5 4.25 x 4.75 120/208/240/277 4.25 x 4.75 Multi-5 4.25 x 5.75 480-120 4.25 x 5.75 480-120 120/208/240/277 4.25 x 4.75 4.25 x 5.75 Multi-5™ Uni-Pak™ 4.25 x 4.75 120/208/240/277 4.25 x 5.75 Multi-5 4.25 x 5.75 120/208/240/277 4.25 x 5.75 Multi-5™ Uni-Pak™ 4.25 x 5.75 480-120 4.25 x 5.75 New New 1230-92S-500K 1230-32S-500K New New 1230-93U-500K 1230-33U-500K New 1230-93S-500K 1230-33S-500K New New 1230-97S-500K New New 1230-57S-500K S70MLTLC3M500K S100MLTLC3M500K S150MLTLC3M500K S15048TLC3M500K S200MLTAC4M500K S20048TAC4M500K S250ML5AC4M500K S250MLTAC4M500K S25048TAC4M500K S250ML5AC4M555K S400ML5AC4M500K S400MLTAC4M500K S40048TAC4M500K S400ML5AC5M500K S400MLTAC5M500K S40048TAC5M500K S400ML5AC4M555K S600MLTAC5M500K S1000MLTAC5M500K S1000ML5AC5M500K S1000ML5AC5M555K S100048TAC5M500K HID PAGE 5-17 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Distributor Replacement Kits Canadian Tri-Tap Distributor Replacement Kits LampType Metal Halide Wattage Voltage Frame Size Old Part Number New Part Number 175 120/277/347 3 x 4 1130-605-502K M175TRIAC30502K 1130-593R-502K M250TRIAC4M502K 1130-598-502K M1000TRIAC5M502K 250 250 4.25 x 4.75 1130-595R-502K 1500 120/277/347 4.25 x 5.75 1130-599-502K 35 50 70 100 175 Pulse Start Metal Halide H.P.S. 4.25 x 4.75 New 120/277/347 1000 120/277/347 3 x 4 400 120/277/347 150 120/277/347 120/277/347 120/277/347 120/277/347 120/277/347 120/277/347 120/277/347 200 120/277/347 320 120/277/347 250 350 400 450 750 70 100 150 250 4.25 x 5.75 3 x 4 3 x 4 11310-604-502K 3 x 4 11310-590-502K 3 x 4 3 x 4 120/277/347 4.25 x 4.75 120/277/347 120/277/347 120/277/347 120/277/347 120/277/347 11310-584-502K New 3 x 4 4.25 x 4.75 120/277/347 New 3 x 4 120/277/347 120/277/347 New New New 4.25 x 4.75 New New 4.25 x 4.75 New 4.25 x 4.75 4.25 x 5.75 New New 3 x 4 12310-579-502K 3 x 4 12310-588-502K 3 x 4 4.25 x 4.75 12310-584-502K M50TRILC3M502K M70TRILC3M502K M100TRILC3M502K M150TRILC3M502K P175TRIAC3M502K P200TRIAC3M502K P250TRIAC4M502K P320TRIAC4M502K P350TRIAC4M502K P400TRIAC4M502K P450TRIAC4M502K P750TRIAC5M502K S70TRILC3M502K S100TRILC3M502K S150TRILC3M502K S400TRIAC5M502K 4.25 x 4.75 1230-595U-502K 1000 120/277/347 4.25 x 5.75 1230-598S-502K S400TRIAC4M502K S1000TRIAC5M502K HID 4.25 x 5.75 M35TRILC3M502K 1230-595S-502K 120/277/347 120/277/347 M1500TRIAC5M502K S250TRIAC4M502K 400 400 M400TRIAC4M502K 1230-593S-502K M250TRIAC3M502K PAGE 5-18 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS METAL HALIDE • 6 0 Hz • Minimum starting temperature: -30° C • Normal and High Power Factor models available MH 175-250 WATT Nom Dimensions Capacitor Ignitor Max Open Total Max UL Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Weight Catalog Distance Bench Volts Number Type Input Current Voltage Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 175 WATT M57, M107 METAL HALIDE LAMP 120 M175120AC3M CWA 213 1.90 305 5 17 PC1 2.2 3.6 10 400 1.65 2.83 1.56x2.69 2.69 6.1 n/a n/a A 230 M175230AC3M CWA 205 1.00 310 3 46 PC1 2.25 3.55 12 400 1.65 3.82 1.56x2.69 2.7 6.7 n/a n/a C 120 or 2.15 5 M175TRIAC30 CWA 211 0.95 305 17 PC1 2.45 3.8 10 400 1.65 2.83 1.56x2.69 2.69 6.8 n/a n/a C 277 or 2 347 0.75 2 120 or 1.90 5 A 208 or M175MLTAC3M CWA 213 1.10 3 C 305 16 PC1 2.2 3.6 10 400 1.65 2.83 1.56x2.69 2.69 6.1 n/a n/a 240 or 0.95 3 B 277 0.85 2 C 120 or 1.94 5 1.11 3 208 or 240 or M175ML5AC3M CWA 208 1.00 300 3 25 PC1 2.3 3.6 10 400 1.65 2.83 1.56x2.69 2.69 6.8 n/a n/a B 277 or 0.83 2 480 0.50 2 480 M17548TAC3M CWA 210 0.51 315 2 15 PC1 2.0 3.3 10 400 1.65 2.83 1.56x2.69 2.69 5.6 n/a n/a D (1) 250 WATT M58 METAL HALIDE LAMP - 4” Frame 230 M250230AC3M CWA 282 1.40 285 4 46 PC1 3.0 4.3 18 400 n/a n/a 1.75 3.1 9.0 n/a n/a D 120 or 2.78 8 B 277 or M250TRIAC3M CWA 295 1.30 320 3 17 PC1 3.0 4.5 15 400 1.85 3.82 2.01x3.01 2.69 9.0 n/a n/a D 347 1.05 3 D 120 or 2.65 8 208 or M250MLTAC3M CWA 297 1.58 5 16 PC1 3.0 315 4.3 15 400 1.85 3.82 2.01x3.01 2.69 9.0 n/a n/a D 240 or 1.30 4 277 1.13 3 120 or 2.50 8 1.50 5 208 or 240 or M250ML5AC3M CWA 280 1.25 290 4 25 PC1 3.0 4.3 15 400 1.6 3.82 2.01x3.01 2.69 9.0 n/a n/a C 277 or 1.10 3 480 0.65 2 347 M250347AC3M CWA 293 1.05 320 3 42 PC1 3.0 4.5 15 400 1.85 3.82 2.01x3.01 2.69 9.0 n/a n/a D 480 M25048TAC3M CWA 292 0.71 320 2 15 PC1 3.0 4.3 15 400 1.85 3.82 2.01x3.01 2.69 9.0 n/a n/a D 3 Capacitors are available as an option for high power factor operation. See page 5-23 for Reference Drawings and Wiring Diagrams. HID CORE & COIL PAGE 5-19 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) MH 250-400 WATT • 6 0 Hz • Minimum starting temperature: -30° C • High Power Factor models available • Feature CWA design HID CORE & COIL BALLASTS METAL HALIDE Nom Dimensions Capacitor Ignitor Max Open Total Max UL Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Weight Catalog Distance Bench Volts Number Type Input Current Voltage Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 250 WATT M58 METAL HALIDE LAMP - 4.75” Frame 120 or 3.05 8 277 or M250TRIAC4M CWA 280 1.25 305 3 17 PC2 1.63 3.63 15 400 1.85 3.82 2.01x3.01 2.69 9.5 n/a n/a B 347 1.05 3 120 or 3.05 8 208 or 1.65 5 310 16 PC2 1.53 3.53 15 400 1.85 3.82 2.01x3.01 2.69 9.5 n/a n/a B M250MLTAC4M CWA 290 240 or 1.55 4 277 1.25 3 120 or 2.42 8 208 or 1.40 5 300 4 25 PC2 1.82 3.62 15 360 1.85 3.82 2.01x3.01 2.69 10.8 n/a n/a A 240 or M250ML5AC4M CWA 282 1.20 277 or 1.00 3 480 0.60 2 480 M25048TAC4M CWA 284 0.61 300 2 15 PC2 1.82 3.62 15 360 1.85 3.82 2.01x3.01 2.69 10.8 n/a n/a B (1) 400 WATT M59 METAL HALIDE LAMP 120 M400120AC4M CWA 458 3.94 299 10 28 PC2 2.0 3.86 24 360 1.85 3.82 2.01x3.01 3.12 11.2 n/a n/a E 230 M400230AC4M CWA 448 2.20 300 6 46 PC2 2.13 3.75 28 425 n/a n/a 2.91 3.88 13.0 n/a n/a D 277 M400277AC4M CWA 458 1.69 299 5 14 PC2 2.0 3.86 24 360 1.85 3.82 2.01x3.01 3.12 11.2 n/a n/a E 120 or 4.22 10 277 or M400TRIAC4M CWA 455 1.67 297 5 17 PC2 2.0 3.9 24 360 1.85 3.82 2.01x3.01 3.12 11.0 n/a n/a C 347 1.44 5 120 or 3.90 10 C 277 or M400TRIAC40 CWA 455 1.70 295 5 29 PC2 2.15 3.90 24 360 n/a n/a 1.91x2.91 3.10 10.5 n/a n/a D 347 1.35 4 D 120 or 3.94 10 208 or 2.20 8 M400MLTAC4M CWA 458 299 16 PC2 2.0 3.9 24 360 1.85 3.82 2.01x3.01 3.12 11.2 n/a n/a E 240 or 1.93 5 277 1.69 5 120 or 4.00 10 208 or 2.30 8 240 or M400ML5AC4M CWA 458 2.00 300 5 25 PC2 2.0 3.9 24 360 1.85 3.82 2.01x3.01 3.12 11.2 n/a n/a E 277 or 1.70 5 480 1.00 50 480 M40048TAC4M CWA 458 1.00 300 3 15 PC2 2.0 3.9 24 360 1.85 3.82 2.01x3.01 3.12 11.0 n/a n/a E HID CORE & COIL See page 5-23 for Reference Drawings and Wiring Diagrams. PAGE 5-20 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS METAL HALIDEFEATURING MULTI-5™ • 60 HZ. • Minimum Starting Temperature: -30° C • Feature CWA Design MH 1000-1500 WATT Nom Dimensions Capacitor Ignitor Max Open Total Max UL Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Weight Catalog Distance Bench Volts Number Type Input Current Voltage Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 1000 WATT M47 METAL HALIDE LAMP 120 M1000120AC5M CWA 1080 9.00 425 23 28 PC3 2.9 4.75 24 480 n/a n/a 2.01x3.01 4.0 18.0 n/a n/a D 230 M1000230AC5M CWA 1080 4.70 420 13 46 PC3 3.4 5.30 30 440 n/a n/a 2.91 3.87 21.0 n/a n/a C 120 or 9.00 20 D 277 or M1000TRIAC5M CWA 1080 3.90 435 10 17 PC3 3.0 4.95 24 480 n/a n/a 2.01x3.01 4.0 19.0 n/a n/a D 347 3.20 8 E 120 or 8.95 20 208 or 5.15 15 D 425 16 PC3 2.9 5.05 24 480 n/a n/a 2.01x3.01 4.0 22.0 n/a n/a M1000MLTAC5M CWA 1080 240 or 4.50 10 277 3.90 10 120 or 9.15 20 F 5.25 15 E 208 or 420 10 25 PC3 2.9 5.05 24 480 n/a n/a 2.01x3.01 4.0 22.0 n/a n/a E 240 or M1000ML5AC5M CWA 1080 4.55 277 or 3.95 10 E 480 2.30 6 E 480 M100048TAC5M CWA 1080 2.30 410 6 15 PC3 2.85 4.80 24 480 n/a n/a 2.01x3.01 4.0 22.0 n/a n/a D 480 M100048TAN5M CWA 1080 2.30 410 6 15 PC3 2.85 4.75 24 480 n/a n/a 2.01x3.01 3.9 22.0 n/a n/a A (1) 1250 WATT M180 METAL HALIDE LAMP 120 or 12.00 30 F 208 or 6.90 20 D 240 or M1250MLTAC5M CWA 1360 6.00 420 15 17 PC3 4.4 6.4 32 440 n/a n/a 1.97x3.66 3.88 25.0 n/a n/a D 277 5.20 15 E (1) 1500 WATT M48 METAL HALIDE LAMP 230 M1500230AC5M CWA 1605 7.00 430 20 46 PC3 4.38 6.18 42(2x21) 480 n/a n/a 1.96x3.65 3.9 30.0 n/a n/a C 120 or 13.70 40 277 or M1500TRIAC5M CWA 1610 6.00 460 20 17 PC3 4.38 6.38 32 525 n/a n/a 1.96x3.65 3.9 29.5 n/a n/a G 347 4.70 15 120 or 14.30 40 F 208 or M1500MLTAC5M CWA 1615 8.30 25 G 455 48 PC3 4.4 6.4 32 525 n/a n/a 1.96x3.65 3.9 30.0 n/a n/a 240 or 7.20 20 F 277 6.20 20 E 480 M150048TAC5M CWA 1620 3.50 445 10 15 PC3 4.4 6.4 32 525 n/a n/a 1.96x3.65 3.9 30.0 n/a n/a E See page 5-23 for Reference Drawings and Wiring Diagrams. HID CORE & COIL PAGE 5-21 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS MH METAL HALIDE DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) 000 200 500 Wiring Diagram 31 Wiring Diagram 17 Wiring Diagram 32 Wiring Diagram 25 Wiring Diagram 33 500K 502K 518 700 718 Bracket W Wiring Diagram 16 S M L BRef. Dwg. 1 PC1 PC2 PC3 L 4.00” 5.25” 7.75” 7.75” W 0.75” 1.25” 2.75” 2.75” M 3.35” 4.60” 6.10” 6.10” S 0.25” 0.25” 0.25” 0.25” See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. REFERENCE DRAWING 1 REFERENCE DRAWING PC1 2.625" 0.438" A .203" Dia Thru 4 Holes 2.188" B 4 Holes ClearedB A for #10 Thru-Bolts A 0.438" 0.438" .199" Dia Thru 4 Holes 0.594" B MAX 0.594" A B A .250" Dia Thru 2 Holes 2.812˝ 2 Holes Cleared for #10 Thru-Bolts 0.656" .218" Dia Thru 4 Holes 0.437" B .250" Dia Thru 2 Holes 0.438" A 2.937" 1.750" 2.188" 2.437" 1.750" 2.438˝ 2.188" 2.188" 3.500˝ 3.938˝ 2.812" 2.625" REFERENCE DRAWING PC2 2.437" 1.218" 2.812" Four 0.250" Male Quick Connect Blade Terminals 3.125" 3.125" 3.750" Wiring Diagram 42 Wiring Diagram 28 Reference Drawing 3 Reference Drawing 2 Cleared Reference Drawing for8 Holes #10 Thru-Bolts 1-A A Reference Drawing 4 B MAX B MAX 4.250˝ 2 Holes Cleared for #10 Thru-Bolts 2 Holes Cleared for #10 Thru-Bolts 0.625" .250" Dia Thru 4 Holes 3.875˝ 3.500" 2.500" .199" Dia Thru 4 Holes REFERENCE DRAWING PC3 4 Holes Cleared Reference Drawing for #10 Thru-Bolts 1 A 1.218" 3.938" .203" Dia Thru 4 Holes A B .250" Dia Thru4.750˝ 4.375˝ 2 Holes 4.375˝ .250" Dia Thru 5.750˝ 5.375˝ 2 Holes 0.637" .250" Dia Thru 4 Holes A 0.637" .250" Dia Thru 8 Holes B A 0.625" .250" Dia Thru 8 Holes B .250" Dia Thru 2 Holes A Wiring Diagram 29 4.375" 4.250" 1.937" 4.375" Four 0.250" Male Quick Connect Terminals 4.250" 3.875" 1.937" 4.750" 4.750" B .250" Dia Thru 2 Holes 3.875" 3.875" 3.875" 1.937" 3.875˝ Four 0.250" Male Quick Connect Terminals WIRING DIAGRAMS 4.250" 4.250˝ Wiring Diagram 46 4.250" 1.937" 4.375" 5.375" 5.750" 4.375" 5.375" 5.750" HID CORE & COIL Wiring Diagram 14 Reference Drawing 6 Reference Drawing 5 0.625" .250" Dia Thru 8 Holes .218" Dia Thru 4 Holes B A 0.625" .250" Dia Thru 8 Holes B A 0.625" .250" Dia Thru 4 Holes B A B .250" Dia Thru 2 Holes .250" Dia Thru 2 Holes 1.062" .250" Dia Thru 2 Holes Reference Drawing 8 Reference Drawing 7 0.687" A 3.437" Wiring Diagram 15 3.875" 4.250" 1.937" 4.375" 5.375" Wiring Diagram 30 2.750" 3.437" 3.875" 4.250" 3.437" 4.125" 1.937" 4.375" 5.375" 5.750" Wiring Diagram 483.875" 4.250" 1.937" 4.375" 4.750" 5.750" Reference Drawing 13 Reference Drawing 15 Reference Drawing 14 PAGE 5-22 B 0.843" 0.812" 3.937" 3.500" Reference Drawing 16 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS PULSE START METAL HALIDE PULSE START MH • 6 0 Hz • Minimum starting temperature: -30° C • Normal and High Power Factor models available 35/39-100 WATT Nom Dimensions Capacitor Ignitor Max Open Total Max UL Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Weight Catalog Distance Bench Volts Number Type Input Current Voltage Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 35/39 WATT M130 METAL HALIDE LAMP 120 or .84 2 277 or M35TRILC3M HX-HPF 54 .40 235 1 4 PC1 0.85 2.15 5 300 1.26 2.36 1.31x2.16 2.2 1.7 MH100-3A 5 A 347 .30 1 120 or .82 2 208 or .48 1 M35MLTLC3M HX-HPF 50 230 3 PC1 240 or .42 1 277 .36 1 (1) 50 WATT M110 METAL HALIDE LAMP — Medium Base 120 or 1.30 3 277 or M50TRILC3M HX-HPF 67 .61 250 2 5 PC1 347 .48 2 120 or 208 or M50MLTLC3M HX-HPF 67 240 or 277 1.16 0.67 252 0.57 0.50 3 3 2 2 0.85 2.0 5 277 1.26 2.83 1.31x2.16 2.2 1.7 MH100-3A 5 A 1.05 2.55 6 300 1.26 2.83 1.31x2.16 2.2 4.25 MH100-3A 10 A 6 300 1.26 2.36 1.31x2.16 2.2 4.25 MH100-3A 10 A 3 PC1 1.05 2.55 3 Capacitors are available as an option for high power factor operation. A B E B A A C A See page 5-23 for Reference Drawings and Wiring Diagrams. PAGE 5-23 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL (1) 70 WATT M98 METAL HALIDE LAMP - Medium Base 120 or 1.85 4 277 or M70TRILC3M HX-HPF 91 0.80 260 2 4 PC1 1.5 2.65 8 280 1.65 2.83 1.31x2.16 2.2 5.0 MH100-3A 10 347 0.65 2 120 or 1.70 4 208 or 1.04 3 M70MLTLC3M HX-HPF 95 250 3 PC1 1.33 2.88 8 300 1.65 2.83 1.31x2.16 2.2 4.25 MH100-3A 10 240 or 0.87 3 277 0.78 2 480 M7048TLC3M HX-HPF 100 0.50 250 1 6 PC1 1.38 2.88 8 300 1.65 2.83 1.31x2.16 2.2 4.25 MH100-3A 10 (1) 70 WATT M85 METAL HALIDE LAMP - Double Ended 120 or 1.70 4 208 or 1.04 3 250 3 PC1 1.38 2.88 8 300 1.65 2.83 1.31x2.16 2.2 4.25 MH70-3B 10 M70MLTLC3D HX-HPF 95 240 or 0.87 3 277 0.78 2 (1) 100 WATT M90 OR M92 METAL HALIDE LAMP - Medium Base 120 or 2.50 7 277 or M100TRILC3M HX-HPF 125 1.10 265 3 4 PC1 1.6 2.95 12 280 1.65 2.83 1.31.2.16 3.13 5.5 MH100-3A 10 347 0.90 3 120 or 2.40 5 208 or 1.45 4 M100MLTLC3M HX-HPF 130 260 13 PC1 1.5 2.8 12 300 1.65 2.83 1.31x2.16 3.12 5.0 MH100-3A 10 240 or 1.20 3 277 1.00 3 480 M10048TLC3M HX-HPF 132 0.62 285 2 6 PC1 1.7 3.0 10 300 1.65 2.83 1.31x2.16 2.7 5.5 MH100-3A 10 (1) 100 WATT M91 METAL HALIDE LAMP - Double Ended 120 or 2.40 5 208 or 1.45 4 M100MLTLC3D HX-HPF 130 260 13 PC1 1.5 2.6 12 300 1.65 2.83 1.31x2.16 3.12 5.0 MH70-3B 10 240 or 1.20 3 277 1.00 3 PULSE START MH 150-200 WATT HID CORE & COIL HID CORE & COIL BALLASTS • 60 Hz • Minimum Starting Temperature: -40° C • Feature CWA Design PULSE START METAL HALIDE Nom Dimensions Capacitor Ignitor Max Open Total Max UL Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Weight Catalog Distance Bench Volts Number Type Input Current Voltage Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 150 WATT M102/M142 METAL HALIDE LAMP - Medium Base 120 or 3.32 10 277 or M150TRILC3M HX-HPF 185 1.48 245 4 5 PC1 2.38 3.65 16 280 1.65 2.83 1.56x2.69 2.69 7.3 MH100-3A 10 D 347 0.65 2 120 or 3.32 10 208 or M150MLTLC3M HX-HPF 185 1.93 5 245 3 PC1 2.38 3.88 16 300 1.65 2.83 1.56x2.69 2.69 7.3 MH100-3A 10 A 240 or 1.66 5 277 1.48 4 120 or 1.50 4 C 208 or M150MLTAC3M CWA 188 0.90 210 3 9 PCI 2.5 3.75 16 330 1.65 3.82 n/a n/a 7.1 MH150-1A 10 D 240 or 0.75 3 C 277 0.65 2 C 480 M15048TLC3M HX-HPF 185 1.00 260 3 6 PC1 2.3 3.6 16 280 1.65 2.83 1.56x2.69 2.69 7.0 MH100-3A 10 F (1) 150 WATT M81 METAL HALIDE LAMP - Double Ended 120 or 3.32 10 208 or 1.93 5 M150MLTLC3D HX-HPF 185 245 3 PC1 2.38 3.88 16 277 1.65 2.83 1.56x2.69 2.69 7.3 MH70-3B 10 D 240 or 1.66 5 277 1.48 4 (1) 175 WATT M152 METAL HALIDE PULSE START LAMP RX-NPF 1.50 n/a n/a n/a n/a 277 P175277RCEM 199 277 3 1 RX1 2.3 3.4 12 300 3.9 MH350-1A 10 C RX-HPF 1.25 1.6 2.8 1.31x2.16 3.9 120 or 1.84 5 277 or P175TRIAC3M CWA 208 0.79 308 2 12 PC1 2.5 3.6 10 400 1.6 2.8 1.31x2.16 3.9 6.8 MH350-1 10 B 347 0.63 2 120 or 2.09 5 3 208 or P175MLTAC3M CWA 208 1.26 306 9 PC1 2.5 3.6 10 400 1.6 2.8 1.31x2.16 3.9 6.8 MH350-1A 10 A 240 or 1.02 3 277 0.96 2 120 or 1.95 5 208 or P175MLTAC3L CWA 198 1.10 285 3 9 PC1 3.10 4.20 11 370 1.65 2.83 n/a n/a 8.5 MH350-1A 2 A 240 or 1.00 3 277 0.80 2 120 or 1.70 5 3 208 or P175MLTAC4L CWA 198 0.95 270 9 PC2 1.77 3.3 12.5 330 1.55 2.83 n/a n/a 8.45 MH350-1A 10 A 240 or 0.85 3 277 0.75 2 120 or 1.80 5 208 or 1.05 3 240 or P175ML5AC3M CWA 210 0.90 295 3 26 PC1 2.6 4.0 10 400 1.6 2.8 2.7 2.7 8.0 MH350-1A 10 B 277 or 0.80 2 480 0.45 2 480 P17548TAC3L CWA 198 0.50 285 2 11 PC1 3.10 4.20 11 360 1.65 2.83 n/a n/a 8.5 MH350-1A 2 A 480 P17548TAC4L CWA 198 0.40 275 2 11 PC2 1.80 3.5 12.5 330 1.6 2.8 n/a n/a 9.6 MH350-1A 10 A (1) 200 WATT M136 METAL HALIDE PULSE START LAMP 277 P200277RCEM RX-HPF 218 0.92 277 4 1 RX1 1.0 2.8 13 280 1.6 3.6 n/a n/a 4.7 MH350-1A 10 A 120 or 277 or P200TRIAC3M CWA 240 347 120 or 208 or 240 or P200ML5AC3M CWA 233 277 or 480 480 P20048TAC3M CWA 232 2.70 1.04 310 0.87 2.66 1.52 1.31 303 1.12 0.68 0.50 305 6 3 12 PC1 2.8 3 6 4 3 26 PC1 2.7 3 2 2 11 PC1 2.8 4.0 11 400 1.6 2.8 2.7 3.6 8.0 MH350-1A 10 C 4.0 11 400 1.6 2.7 n/a n/a 8.0 MH350-1A 10 C 4.1 11 400 1.6 2.8 1.56x2.69 2.7 8.5 MH350-1 10 C PAGE 5-24 HID CORE & COIL BALLASTS PULSE START METAL HALIDE • 60 Hz • Minimum Starting Temperature: -40° C • CWA and High Power Factor Models Available PULSE START MH 250-320 WATT See page 5-29 for Reference Drawings and Wiring Diagrams. PAGE 5-25 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL Nom Dimensions Capacitor Ignitor Max Open Total Max UL Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Weight Catalog Distance Bench Volts Number Type Input Current Voltage Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 250 WATT M153 METAL HALIDE PULSE START LAMP RX-NPF 2.00 n/a n/a n/a n/a 277 P250277RCEM 278 5 1 RX1 1.0 2.8 17.5 300 4.8 MH350-1A 10 A 277 RX-HPF 1.25 1.6 3.7 n/a n/a 120 or 2.61 8 277 or P250TRIAC4M CWA 300 1.28 292 3 12 PC2 1.4 3.4 14 400 1.6 3.7 2.3 4.0 9.0 MH350-1A 10 A 347 1.09 3 120 or 2.40 8 5 208 or P250MLTAC40 CWA 291 1.40 277 9 PC2 1.45 3.10 17 360 1.6 3.7 2.3 3.1 9.0 MH350-1A 10 A 240 or 1.20 5 277 1.05 3 120 or 2.50 8 5 208 or P250MLTAC4L CWA 283 1.50 270 9 PC2 2.05 3.65 17 360 1.65 3.82 2.3 3.1 10.9 MH350-1A 15 A 240 or 1.30 5 277 1.10 3 120 or 2.45 8 208 or 1.42 5 240 or P250ML5AC4M CWA 285 1.22 290 5 26 PC2 2.0 3.9 14 400 1.6 3.7 1.56x2.69 3.1 11.3 MH350-1A 10 A 277 or 1.05 3 480 0.62 2 120 or 2.45 8 208 or 1.42 5 240 or P250ML5AC4M CWA 285 1.22 290 5 26 PC2 2.0 3.9 14 400 1.6 3.7 1.56x2.69 3.1 11.3 MH350-1A 10 A 277 or 1.05 3 480 480 P25048TAC4L CWA 283 0.60 275 2 11 PC2 1.9 3.6 17 360 1.65 3.82 n/a n/a 10.0 MH350-1A 10 A (1) 320 WATT M154 METAL HALIDE PULSE START LAMP RX-NPF 3.05 10 n/a n/a n/a n/a 277 P320277RCEM 348 277 1 RX1 1.5 3.3 22.5 280 6.8 MH350-1A 10 A RX-HPF 1.51 6 1.8 3.6 n/a n/a 120 or 4.50 8 277 or P320TRIAC4M CWA 370 2.00 281 4 12 PC2 2.0 3.7 20.5 400 1.6 3.7 2.9 3.6 11.0 MH350-1A 10 C 347 1.50 3 120 or 3.10 9 5 208 or P320MLTAC40 CWA 364 1.80 275 9 PC2 2.0 3.9 21.0 360 1.85 3.82 2.9 3.6 11.0 MH350-1A 10 A 240 or 1.55 5 277 1.35 4 120 or 4.00 10 208 or 2.40 7 240 or P320ML5AC4M CWA 370 2.10 280 5 26 PC2 2.0 3.9 20.5 360 1.8 3.7 1.91x2.91 3.6 11.3 MH350-1A 10 D 277 or 1.85 5 480 1.06 3 120 or 4.00 10 208 or 2.40 7 240 or P320ML5AN4M CWA 405 2.10 282 5 26 PC2 2.0 3.86 20.5 360 1.85 3.82 1.75 3.1 11.3 MH350-1A 10 A 277 or 1.85 5 480 1.06 3 120 or 3.10 10 208 or 1.80 7 240 or P320ML5AC4L CWA 363 1.55 275 8 26 PC2 1.88 3.8 21 360 n/a n/a 2.91 3.13 12.0 MH350-1A 10 A 277 or 1.35 5 480 0.80 3 PULSE START MH HID CORE & COIL 320-350 WATT • 60 Hz • Minimum Starting Temperature: -40° C • Feature CWA Design HID CORE & COIL BALLASTS PULSE START METAL HALIDE Nom Dimensions Capacitor Ignitor Max Open Total Max UL Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Weight Catalog Distance Bench Volts Number Type Input Current Voltage Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 350 WATT M131 METAL HALIDE PULSE START LAMP 120 or 3.10 8 208 or 1.80 5 240 or P320ML5AN4L CWA 363 1.55 275 5 26 PC2 1.88 3.8 21 360 1.85 3.82 n/a n/a 12.0 MH350-1A 10 A 277 or 1.35 4 480 0.80 3 480 CWA 364 0.80 280 3 11 PC2 2.0 3.9 21 360 1.85 3.82 n/a n/a 11.0 MH350-1A 10 A P32048TAC4L RX-NPF 3.80 — — — — 277 377 277 8 1 RX1 1.5 3.3 22.5 300 6.8 MH350-1 10 A P350277RCEM RX-HPF 2.34 n/a n/a 1.56x2.69 3.9 120 or 4.00 10 277 or P350TRIAC4M CWA 405 2.00 280 5 12 PC2 2.0 4.0 21 400 n/a n/a 2.9 3.1 11.5 MH350-1A 10 C 347 1.50 3 120 or 3.40 9 208 or P350MLTAC4M 2.00 6 CWA 400 275 9 PC2 2.0 3.9 22 360 n/a n/a 2.7 3.9 11.0 MH350-1A 10 C 240 or 1.70 5 277 1.45 4 120 or 2.40 9 208 or 6 P350MLTAN4M CWA 400 2.00 275 47 PC2 2.0 3.9 22 360 n/a n/a 2.7 3.9 11.0 MH350-1A 10 A 240 or 1.70 5 277 1.45 4 120 or 4.22 10 208 or 2.49 7 240 or P350ML5AC4M CWA 405 2.16 282 5 26 PC2 2.0 3.9 21 400 n/a n/a 1.91x2.91 3.1 11.3 MH350-1A 10 D 277 or 1.87 5 480 1.09 3 120 or 4.22 10 208 or 2.49 7 240 or P350ML5AN4M CWA 405 2.16 282 5 26 PC2 2.0 3.9 21 400 n/a n/a 1.91x2.91 3.1 11.3 MH350-1A 10 D 277 or 1.87 5 480 1.09 3 120 or 3.35 10 208 or 1.90 7 240 or P350ML5AC4L CWA 397 1.65 275 9 26 PC2 1.88 3.8 22 360 1.85 3.82 2.69 3.9 12.0 MH350-1A 10 B 277 or 1.45 5 480 0.85 3 120 or 3.35 9 208 or 1.90 6 240 or P350ML5AN4L CWA 397 1.65 275 5 26 PC2 1.88 3.8 22 360 1.85 3.82 2.69 3.9 12.0 MH350-1A 10 A 277 or 1.45 4 480 0.85 3 480 P35048TAC4L CWA 397 0.85 280 3 11 PC2 2.00 3.9 22 360 1.85 3.82 2.69 3.9 11.0 MH350-1A 10 C See page 5-29 for Reference Drawings and Wiring Diagrams. PAGE 5-26 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS PULSE START METAL HALIDE • 60 Hz • Minimum Starting Temperature: -40° C • CWA and High Power Factor Models Available PULSE START MH 400 WATT Nom Dimensions Capacitor Ignitor Max Open Total Max UL Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Weight Catalog Distance Bench Volts Number Type Input Current Voltage Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 400 WATT M135 METAL HALIDE PULSE START LAMP 120 or 4.40 10 277 or P400TRIAC4M CWA 457 2.01 287 5 12 PC2 2.0 3.8 24 400 1.8 3.6 2.9 3.1 11.0 MH350-1A 10 D 347 1.52 4 120 or 4.05 10 277 or P400TRIAN4M CWA 454 1.95 285 5 12 PC2 2.0 3.9 24 400 1.8 3.6 2.9 3.1 11.0 MH350-1A 10 D 347 1.40 4 120 or 3.90 10 B 208 or P400MLTAC4L CWA 454 2.25 280 7 9 PC2 2.30 4.20 26 330 1.85 3.82 n/a n/a 11 MH350-1A 10 B 240 or 1.95 5 B 277 1.70 5 C 120 or 4.00 10 208 or 2.40 7 240 or P400ML5AC4M CWA 457 2.10 286 5 26 PC2 2.0 3.9 24 400 1.8 3.7 1.91x2.91 3.1 11.3 MH350-1A 10 D 277 or 1.85 5 480 1.06 3 120 or 3.90 10 208 or 2.25 7 240 or P400ML5AN4M CWA 455 1.95 286 5 26 PC2 2.0 3.9 24 400 1.8 3.7 1.91x2.91 3.1 11.3 MH350-1A 10 D 277 or 1.70 5 480 0.95 3 480 P40048TAC4L CWA 455 1.00 275 3 11 PC2 2.3 4.2 28 330 1.85 3.82 n/a n/a 12 MH350-1A 10 D 480 P40048TAC4M CWA 457 1.00 285 3 11 PC2 2.0 3.9 24 400 1.8 3.6 3.7 3.1 11.3 MH350-1A 10 D See page 5-29 for Reference Drawings and Wiring Diagrams. HID CORE & COIL PAGE 5-27 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) PULSE START MH HID CORE & COIL 450-1000 WATT • 60 Hz • Minimum Starting Temperature: -40° C • CWA and High Power Factor Models Available HID CORE & COIL BALLASTS PULSE START METAL HALIDE Nom Dimensions Capacitor Ignitor Max Open Total Max UL Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Weight Catalog Distance Bench Volts Number Type Input Current Voltage Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 450 WATT M144 METAL HALIDE PULSE START LAMP 120 or 4.40 10 208 or 2.60 8 285 9 PC2 2.3 4.0 26.5 400 1.8 4.7 2.9 3.5 11.0 MH350-1A 10 C P450MLTAC4M CWA 510 240 or 2.20 7 277 1.90 5 120 or 4.44 10 208 or 2.56 8 240 or P450ML5AC4M CWA 510 2.38 305 7 26 PC2 2.6 4.7 26.5 400 1.8 4.7 1.91x2.91 3.9 12.0 MH350-1 10 D 277 or 1.92 5 480 1.22 4 480 P45048TAC4M CWA 511 1.40 305 10 11 PC2 2.7 4.7 26.5 400 0.8 4.6 2.9 3.5 12.0 MH350-1A 10 D (1) 750 WATT M149 METAL HALIDE PULSE START LAMP 120 or 7.05 15 B 277 or P750TRIAC5M CWA 820 3.05 340 8 12 PC3 2.8 4.6 28 425 n/a n/a 2.91 3.9 18.0 P750-1B 10 C 347 2.45 8 C 120 or 7.10 18 D A 208 or 4.10 10 340 9 PC3 2.8 4.8 28 400 n/a n/a 2.91 3.9 18.0 P750-1B 10 P750MLTAC5M CWA 825 240 or 3.55 10 B 277 3.10 8 B 120 or 6.95 18 C 208 or 4.00 10 C 240 or P750ML5AC5M CWA 820 3.50 340 10 26 PC3 2.8 4.9 28 400 n/a n/a 2.9 3.9 19.0 P750-1B 16 D 277 or 3.00 8 D 480 1.75 5 C 480 P75048TAC5M CWA 822 1.80 335 5 11 PC3 2.8 4.8 28 400 n/a n/a 2.91 3.9 18.0 P750-1B 10 D (1) 875 WATT M166 METAL HALIDE PULSE START LAMP 120 or 8.50 20 D C 208 or 5.30 15 395 9 PC3 2.8 4.5 24 440 n/a n/a 2.9 3.9 17.5 HPS1000-48 10 P875MLTAC5M CWA 945 240 or 4.30 10 A 277 3.80 10 C 120 or 8.05 20 E 208 or 4.65 12 C 240 or P875ML5AC5M CWA 950 4.05 395 10 26 PC3 2.8 4.8 24 440 n/a n/a 2.9 3.9 19.4 HPS1000-4B 10 B 277 or 3.50 10 C 480 2.00 5 C (1) 1000 WATT M141 METAL HALIDE PULSE START LAMP 120 or 9.00 20 208 or 5.20 15 420 9 PC3 2.9 5.1 24 480 n/a n/a 2.9 3.9 22.0 HPS1000-4B 20 D P1000MLTAC5M CWA 1080 240 or 4.50 10 277 3.90 10 120 or 8.95 20 G 208 or 5.15 15 B 240 or P1000ML5AC5M CWA 1080 4.45 420 10 26 PC3 2.9 5.1 24 480 n/a n/a 2.9 3.9 22.0 HPS1000-4B 20 C 277 or 3.85 10 C 480 2.25 10 C 480 P100048TAC5M CWA 1080 2.55 410 10 11 PC3 2.8 4.8 24 480 n/a n/a 2.9 3.9 22.0 HPS1000-4B 15 D See page 5-29 for Reference Drawings and Wiring Diagrams. PAGE 5-28 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) PULSE START MH HID CORE & COIL BALLASTS PULSE START METAL HALIDE DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) 000 200 500 500K REFERENCE DRAWING PC1 REFERENCE DRAWING PC2 4 Holes Cleared for #10 Thru-Bolts 4 Holes Cleared for #10 Thru-Bolts A A B MAX B MAX 2.812˝ 2 Holes Cleared for #10 Thru-Bolts 502K 3.875˝ 2.438˝ 4.250˝ 2 Holes Cleared for #10 Thru-Bolts 3.500˝ 3.938˝ 4.375˝ 4.750˝ 518 700 REFERENCE DRAWING PC3 718 REFERENCE DRAWING RX1 8 Holes Cleared for #10 Thru-Bolts A B MAX Bracket W S 2 Holes Cleared for #10 Thru-Bolts M L BRef. Dwg. PC1 PC2 PC3 RX1 L 5.25” 7.75” 7.75” 4.00” W 1.25” 1.25” 2.75” 0.75” M 4.60” 5.75” 6.10” 3.35” 4.250˝ S 0.25” 0.25” 0.25” 0.25” 3.875˝ 4.375˝ 5.375˝ 5.750˝ See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. Wiring Diagram 5 Wiring Diagram 11 Wiring Diagram 6 Wiring Diagram 12 Wiring Diagram 9 Wiring Diagram 26 Wiring Diagram 13 Wiring Diagram 47 WIRING DIAGRAMS Wiring Diagram 1 Wiring Diagram 3 HID CORE & COIL Wiring Diagram 4 PAGE 5-29 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HPS 35-100 HID CORE & COIL WATT • 60 Hz • Minimum Starting Temperature: -40° C • Normal and High Power Factor Models HID CORE & COIL BALLASTS HIGH PRESSURE SODIUM Nom Dimensions Capacitor Ignitor Max Open Total Max UL Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Weight Catalog Distance Bench Volts Number Type Input Current Voltage Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 35 WATT S76 HIGH PRESSURE SODIUM LAMP 120 2 2 1a 0.6 1.7 14 120 n/a n/a 1.56x2.69 2.7 1.5 HPS150-3A 3 A 1233-251W ◆ R-HPF 3 43 0.65 1201 Permanently Attached RX-NPF 0.85 120 2 120 S35120RCEM 44 1 5 0.6 1.7 14 240 — — 1.9 2.3 1.0 HPS150-3A 10 A RX-HPF 0.63 3 (1) 50 WATT S68 HIGH PRESSURE SODIUM LAMP 1233-35W ◆ R-HPF 3 60 0.90 120 5 2 1a 0.9 2.4 20 240 n/a n/a 1.56x2.69 3.1 2.0 HPS150-3A 3 A 1201 Permanently Attached RX-NPF 1.12 8 120 S50120RCEM 60 120 1 5 0.8 2.0 20 240 — — 1.9 2.3 2.0 HPS150-3A 3 A RX-HPF 0.90 5 120 or 1.24 5 208 or 0.60 3 130 3 PC1 1.3 2.7 5 300 1.2 2.2 2.2 2.2 4.1 HPS150-3A 5 A S50MLTLC3M HX-HPF 66 240 or 0.52 3 277 0.45 2 (1) 70 WATT S62 HIGH PRESSURE SODIUM LAMP 1.30 120 5 2 1a 1.3 2.8 2.8 120 1.6 2.7 n/a n/a 2.5 HPS150-3A 3 A 1233-142W ◆ R-HPF 83 120 Permanently Attached RX-NPF 1.60 8 120 S70120RCEM 80 120 1 RX1 1.1 2.8 28 240 n/a n/a 1.3 2.7 2.0 HPS150-3A 3 A RX-HPF 1.30 4 230 S70230LC3M HX-HPF 88 1.00 120 2 35 PC1 1.9 3.2 10 280 1.6 2.7 1.3 2.7 5.7 HPS150-3A 3 A 120 or 1.50 5 S7027TLC3M HX-HPF 98 120 36 PC1 1.3 2.8 7 300 n/a n/a 1.3 2.2 4.1 HPS150-3A 10 B 277 0.65 2 120 or 1.50 5 277 or S70TRILC3M HX-HPF 94 0.65 120 2 4 PC1 2.0 3.5 7 300 1.2 2.7 1.31x2.16 2.2 4.2 HPS150-3A 10 B 347 0.50 2 120 or 1.50 5 3 208 or S70MLTLC3M HX-HPF 98 0.88 120 3 PC1 1.3 2.8 7 300 1.2 2.8 1.31x2.16 2.2 4.2 HPS150-3A 10 B 240 or 0.75 3 277 0.65 2 480 S7048TLC3M HX-HPF 94 0.34 120 2 6 PC1 1.8 2.9 7 300 1.2 2.8 1.3 2.2 5.6 HPS150-3A 10 A (1) 100 WATT S54 HIGH PRESSURE SODIUM LAMP -1233-10W ◆ R-HPF 3 117 1.80 120 8 2 1a 1.5 2.9 40 240 1.6 3.6 1.87 2.9 2.8 HPS150-3A 3 A 120 1 Permanently Attached RX-NPF 115 2.24 10 120 S100120RCEM 120 1 5 1.50 2.8 40 240 — — 1.8 2.7 2.0 HPS150-3A 10 A RX-HPF 112 1.81 8 120 or 2.20 3 S10027TLC3M HX-HPF 122 120 36 PC1 2.0 3.4 10 330 1.6 2.7 1.3 2.7 5.9 HPS150-3A 10 B 277 0.95 2 120 or 2.20 8 277 or S100TRILC3M HX-HPF 130 0.95 120 3 5 PC1 2.0 3.5 10 330 1.2 2.7 1.31x2.16 2.7 5.9 HPS150-3A 10 B 347 0.69 2 120 or 2.20 8 208 or S100MLTLC3M HX-HPF 122 1.30 5 120 3 PC1 2.0 3.4 10 330 1.2 2.7 2.2 2.7 6.0 HPS150-3A 10 B 240 or 1.10 5 277 0.95 3 480 S10048TLC3M HX-HPF 135 0.57 120 2 6 PC1 2.0 3.3 10 277 1.6 2.8 1.3 2.2 6.2 HPS150-3A 5 E 1 3 ◆ Also can be used on a 277 volt line in conjuction with the step down transformers Capacitors are available as an option for High Power Factor operation Ballast has built-in starter. PAGE 5-30 See pages 5-34 and 5-35 for Reference Drawings and Wiring Diagrams. FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS HIGH PRESSURE SODIUM • 60 Hz • Minimum Starting Temperature: -40° C • CWA, Normal and High Power Factor Models HPS 150-250 WATT Ballast has built-in starter. * Also can be used on a 277 volt line in conjunction with the step-down transformers described on page 5-53. 3 Capacitors are available as an option for high power factor operation. ◆ PAGE 5-31 See pages 5-34 and 5-35 for Reference Drawings and Wiring Diagrams. HID CORE & COIL Nom Dimensions Capacitor Ignitor Max Open Total Max UL Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Weight Catalog Distance Bench Volts Number Type Input Current Voltage Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 150 WATT S55 HIGH PRESSURE SODIUM LAMP 1233-154W ◆ R-HPF 3 171 2.40 120 8 2 1a 2.0 3.4 52 240 1.8 3.0 2.12 2.9 3.5 HPS150-3A 3 A 120 1 Permanently Attached RX-NPF 4.40 120 S150120RCEM 168 120 5 1 5 2.0 3.1 15 240 n/a n/a 2.0 2.9 3.3 HPS150-3A 3 A RX-HPF 2.35 208 S150208LC3M HX-HPF 190 0.95 120 5 37 PC1 2.3 3.8 14 300 n/a n/a 1.5 2.7 7.0 HPS150-3A 10 C 120 or 1.90 10 B S15027TLC3M HX-HPF 295 185 36 PC1 2.5 3.9 14 280 n/a n/a 2.7 2.7 7.0 HPS150-3A 10 277 0.80 5 A 120 or 3.00 10 B 277 or S150TRILC3M HX-HPF 188 1.35 120 5 5 PC1 2.3 3.7 14 300 1.6 2.8 1.56x2.69 2.7 7.0 HPS150-3A 10 C 347 1.00 4 B 120 or 1.90 10 B 5 A 208 or S150MLTLC3M HX-HPF 188 1.00 120 3 PC1 2.5 3.9 14 280 1.6 2.8 2.7 2.7 7.0 HPS150-3A 10 240 or 0.95 5 B 277 0.80 5 A 480 S15048TLC3M HX-HPF 189 0.72 120 3 6 PC1 3.0 4.5 14 277 1.6 2.7 1.56x2.69 2.7 8.7 HPS150-3A 10 D (1) 150 WATT S56 HIGH PRESSURE SODIUM LAMP 120 1.65 5 1.50 3 208 CWA 188 210 9 PC1 2.5 3.9 20 240 1.6 3.6 n/a n/a 8.0 HPS150-3A 10 D S150MLTAC3M 240 0.85 3 277 0.75 3 (1) 200 WATT S66 HIGH PRESSURE SODIUM LAMP R-NPF 2.80 8 — — — — — — 240 225 240 1 4 1.5 3.0 5.3 HPS450-1B 5 A 1233-183S 2.00 3 22.5 240 n/a n/a 1.56X2.69 3.5 R-HPF 3 120 2.00 7 277 S200TRIAC4M CWA 233 0.86 184 3 12 PC2 1.4 3.3 28 280 n/a n/a 1.91x2.91 3.1 8.7 HPS400-3A 10 C 347 0.68 3 120 or 2.10 7 208 or 1.20 4 CWA 230 175 9 PC2 1.2 3.0 28 300 1.8 3.7 1.91X2.91 3.1 8.5 HPS400-3A 10 S200MLTAC4M B 240 or 1.00 4 277 0.88 3 480 S20048TAC4M CWA 240 0.56 172 2 34 PC2 2.0 3.8 28 280 1.6 4.6 1.7 3.1 11.0 HPS400-3A 10 C (1) 250 WATT S50 HIGH PRESSURE SODIUM LAMP R-NPF 3.50 10 — — — — — — 240 278 240 1 4 2.0 3.5 6.8 HPS450-1B 5 A 1233-24S R-HPF 2.50 5 28 240 n/a n/a 1.87 2.3 120 S250120AC4M CWA 295 2.50 185 8 38 PC2 1.8 3.7 35 330 n/a n/a 1.8 3.1 10.3 HPS400-3A 10 A 230 S250230AC4M CWA 280 1.24 188 5 39 PC2 1.7 3.6 40 300 n/a n/a 1.8 3.9 10.3 HPS400-3A 3 B 240 S250240AC4M CWA 295 1.20 185 4 40 PC2 1.8 3.7 35 330 n/a n/a 1.8 3.1 10.3 HPS400-3A 10 A 120 2.50 8 277 S250TRIAC4M CWA 300 1.20 190 4 12 PC2 1.7 3.8 35 330 1.6 3.7 1.91x2.91 3.1 10.3 HPS400-3A 10 C 347 1.00 3 120 2.50 8 208 1.40 5 S250MLTAC4M CWA 295 190 9 PC2 1.8 3.7 35 330 1.6 3.7 1.91x2.91 3.1 10.3 HPS400-3A 10 A 240 1.20 4 277 1.10 4 120 2.50 8 208 1.40 5 240 S250ML5AC4M CWA 300 1.20 200 4 26 PC2 2.0 3.8 35 330 1.6 3.7 1.91x2.91 3.1 14.0 HPS400-3A 10 A 277 1.10 4 480 0.60 2 480 S250480AC4M CWA 285 0.62 200 2 39 PC2 1.8 3.7 35 280 1.8 4.6 n/a n/a 10.4 HPS400-3A 5 A 480 S25048TAC4M CWA 285 0.62 200 2 11 PC2 1.8 3.7 35 280 1.6 3.7 1.91x2.91 3.1 10.4 HPS400-3A 5 A HPS 400-430 WATTS • 60 Hz • Minimum Starting Temperature: -40° C • CWA, Normal and High Power Factors Models Available HID CORE & COIL BALLASTS HIGH PRESSURE SODIUMFEATURING MULTI-5™ Nom Dimensions Capacitor Ignitor Max Open Total Max UL Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Weight Catalog Distance Bench Volts Number Type Input Current Voltage Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP - 4 3/ ” Frame 230 S400230AC4M CWA 465 2.05 190 8 39 PC2 2.5 4.3 64 300 n/a n/a 1.8 3.2 15.5 HPS400-3A 10 D 277 S400277AC4M CWA 460 1.70 192 5 41 PC2 2.32 4.1 55 240 1.8 4.6 1.8 3.9 14.0 HPS400-3A 10 D 120 or 3.95 10 277 or S400TRIAC4M CWA 465 1.70 192 5 12 PC2 2.32 4.1 55 240 1.8 3.7 1.91x2.91 3.5 14.0 HPS400-3A 10 D 347 1.35 4 120 or 3.80 10 208 or 2.20 6 S400MLTAC4M CWA 463 190 9 PC2 2.32 4.1 55 240 1.8 3.7 1.91x2.91 3.5 14.0 HPS400-3A 10 D 240 or 1.80 5 277 1.70 5 120 or 3.95 10 208 or 2.30 6 240 or S400ML5AC4M CWA 465 2.00 190 5 26 PC2 2.44 4.3 55 240 1.8 3.7 1.91x2.91 3.5 14.0 HPS400-3A 10 D 277 or 1.70 5 480 1.00 3 480 S400480AC4M CWA 464 1.00 190 3 11 PC2 2.32 4.1 55 240 1.8 4.6 1.8 3.9 14.0 HPS400-3A 10 D 480 S40048TAC4M CWA 464 1.00 190 3 11 PC2 2.32 4.1 55 240 1.8 3.7 1.91x2.91 3.5 14.0 HPS400-3A 10 D (1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP - 5 3/ ” Frame 120 or 3.90 10 277 or S400TRIAC5M CWA 467 1.70 200 5 12 PC2 2.2 4.1 48 280 2.0 4.7 1.91x2.91 3.9 16.0 HPS400-3A 10 E 347 1.35 4 120 or 3.95 10 208 or 2.30 6 200 9 PC3 2.25 4.1 48 280 2.0 4.7 1.91x2.91 3.9 16.0 HPS400-3A 10 D S400MLTAC5M CWA 470 2.00 5 240 or 277 1.70 5 120 or 4.00 10 208 or 2.30 6 240 or S400ML5AC5M CWA 468 2.00 200 5 26 PC3 2.5 4.5 48 300 2.0 4.7 1.91x2.91 3.9 17.5 HPS400-3A 10 D 277 or 1.75 5 480 1.00 3 480 S40048TAC5M CWA 467 1.00 200 3 11 PC3 2.25 4.1 48 280 2.0 4.7 1.91x2.91 3.9 16.0 HPS400-3A 10 D (1) 430 WATT SON AGRO HIGH PRESSURE SODIUM LAMP 120 or 4.50 10 208 or 2.50 8 205 9 PC2 2.2 4.3 48 330 2.0 4.7 1.91x2.91 3.9 11.0 HPS400-3A 10 D S430MLTAC4M CWA 490 2.10 7 240 or 277 1.80 5 4 4 Capacitors are available as an option for high power factor operation. See pages 5-34 and 5-35 for Reference Drawings and Wiring Diagrams. HID CORE & COIL 3 PAGE 5-32 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS HIGH PRESSURE SODIUM • 6 0 Hz • Minimum starting temperature: -40° C • CWA models available HPS 600-1000 WATT Nom Dimensions Capacitor Ignitor Max Open Total Max UL Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Weight Catalog Distance Bench Volts Number Type Input Current Voltage Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number to lamp (ft) Top Rise (1) 600 WATT S106 HIGH PRESSURE SODIUM LAMP 120 or 5.10 20 208 or 3.10 15 CWA 640 240 9 PC3 3.0 5.0 55 300 1.8 4.7 1.91x2.91 3.9 21.0 HPS600-1B 10 A S600MLTAC5M 240 or 2.70 10 277 2.35 10 (1) 1000 WATT S52 HIGH PRESSURE SODIUM LAMP 220 or 5.15 15 230 or S1000230AC5M CWA 1100 5.00 405 15 39 PC3 4.0 5.8 36 540 n/a n/a 3.66 4.25 25.5 HPS1000-4B 10 D 240 4.80 15 120 or 9.50 20 S100024TAC5M CWA 1100 440 40 PC3 3.7 5.7 26 525 n/a n/a 1.8 4.3 26.0 HPS1000-4B 10 C 240 4.80 10 120 or 9.60 20 277 or S1000TRIAC5M CWA 1100 4.30 440 10 12 PC3 3.8 5.8 26 525 n/a n/a 1.9 2.9 27.0 HPS1000-4B 15 D 347 3.40 10 120 or 9.50 20 5.50 15 208 or S1000MLTAC5M CWA 1100 440 9 PC3 3.7 5.7 26 525 n/a n/a 1.91x2.91 4.3 26.0 HPS1000-4B 15 C 240 or 4.80 10 277 4.20 10 120 or 9.10 20 5.40 15 208 or 240 or S1000ML5AC5M CWA 1048 4.60 440 10 26 PC3 3.7 5.6 26 480 n/a n/a 1.91x2.91 4.3 26.0 HPS1000-4B 15 D 277 or 4.10 10 480 2.45 8 480 S1000480AC5M CWA 1100 2.45 440 8 11 PC3 3.7 6.0 26 500 n/a n/a 1.8 4.3 25.0 HPS1000-4B 15 D 480 S100048TAC5M CWA 1100 2.45 440 8 11 PC3 3.7 6.0 26 525 n/a n/a 1.91x2.91 4.3 25.0 HPS1000-4B 15 D See pages 5-34 and 5-35 for Reference Drawings and Wiring Diagrams. HID CORE & COIL PAGE 5-33 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS HPS HIGH PRESSURE SODIUM DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) REFERENCE DRAWING 1 000 200 500 REFERENCE DRAWING 1a 2.625" 0.438" B A 0.438" 0.594" A .203" Dia Thru 4 Holes 2.188" .203" Dia Thru 4 Holes 500K B B A 2.625" 0.438" 0.438" .199" Dia Thru A 4 Holes 0.438" .250" Dia Thru .199" Dia Thru 2 Holes 4 Holes .250" Dia Thru 2 Holes 0.594" B A 2.188" 0.438" 0.594" 0.594" 0.438" 0.438" 502K 1.750" 2.188" 518 1.750" 2.625" 2.188" 700 2.437" 1.750" 2.188" 2.188" 2.812" 1.750" 2.188" .203" Dia Thru 4 Holes 2.188" 2.625" 1.218" 2.437" 2.812" Reference Drawing 1 Reference Drawing REFERENCE DRAWING 4 1 Reference Drawing 1-A Reference Drawing REFERENCE DRAWING 1-A Reference Drawing 2 Reference D 2 5 " A 0.656" .218" Dia Thru 4 Holes 0.437" B B A .250"Bracket Dia Thru W 2 Holes 3.937" 3.500" 2.500" 4.250" B A Connect Terminals Reference Drawing 6 Reference Drawing 4 Holes Cleared for #10 Thru-Bolts 6 A 0.687" A B 0.625" .250" Dia Thru 8 Holes A .218" Dia Thru 4 Holes B A 0.687" 1.062" .218" Dia Thru 4 Holes B .250" Dia Thru 2 Holes 3.875˝ 3.500˝ 3.938˝ 4.250" 1.937" 5.375" 4.375" 4.375˝ 4.750˝ 4.250" 1.937" 3.437" 4.375" 3.875" 5.375" 4.250" 1.937" 5.750" 5.750" 4.375" Reference Drawing 8 Reference Drawing 7 0.625" .250" Dia Thru 8 Holes A 0.625" .250" Dia Thru 4 Holes B A A B 1.062" 3.437" 3.437" 2.750" 3.875" 5.375" REFERENCE DRAWING PC3 5.375" HID CORE & COIL 4.250˝ 2 Holes Cleared for #10 Thru-Bolts 3.875" 4.375" 4.375" REFERENCE DRAWING PC2 2.812˝ 0.625" .250" Dia Thru 8 Holes .250" Dia Thru 2 Holes 5.750" 2.750" 3.437" 3.437" 4.125" 3.437" 4.125" 5.750" Reference Drawing 13 Reference Drawing B MAX 13 8 Holes Cleared for #10 Thru-Bolts A Reference Drawing 14 Reference Drawing 14 2 Holes Cleared for #10 Thru-Bolts B .250" Dia Thru 2 Holes .250" Dia Thru 2 Holes 4.250˝ 3.875" 4.250" 4.750" B MAX Four 0.250" 1.937" B 4.750" 4.750" Reference Drawing 4 Holes5 Cleared for #10 Thru-Bolts Reference Drawing A 5 B 2 Holes Cleared for #10 Thru-Bolts .250" Dia Thru 2 Holes PC1 4.375" 3.875" 4.250" 1.937" 4.375" 1.937" Reference Drawing REFERENCE4 DRAWING 2.438˝ Male Quick 4.250" 4.750" A Four 0.250" Male Quick Connect Terminals Four 0.250" Male Quick Connect Terminals 3.875" 4.250" 1.937" 4.375" 1.937" 3.875" B .250" Dia Thru 2 Holes 3.750" 3.875" 4.250" 0.625" .250" Dia Thru 8 Holes 3.875" B 3.125" B MAX A A A 0.637" .250" Dia Thru 4 Holes .250" Dia Thru 2 Holes .250" Dia Thru 2 Holes 3.125" Reference Drawing 3 .250" Dia Thru 2 Holes A B 0.625" .250" Dia Thru 4 Holes .250" Dia Thru 2 Holes 2.937" See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. 0.637" .250" Dia Thru 8 Holes 0.637" .250" Dia Thru 4 Holes 0.625" .250" Dia Thru 4 Holes L 2.437" W M S 0.250" Male Four Quick Connect 1.218" Blade Terminals 4.00” 0.75” 3.35” 0.25” 2.812" .199" Dia Thru0.25” 5.25” 1.25” 4.60” 4 Holes 7.75” 1.25” 5.75” 0.25” Drawing B 0.843" S0.812" M L BRef. Dwg. 1, 1a, 5 PC1, 4 PC2, PC3 A 3.875˝ 4.375˝ 5.375˝ 5.750˝ 3.875" 1.937" 4.375" 5.375" 5.750" Reference Drawing 15 4.250" 1.937" 4.375" 4.750" Reference Drawing 16 PAGE 5-34 3.500" 3.938" .203" Dia Thru 4 Holes 718 3.500" 3.938" 1.218" FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS HPS HIGH PRESSURE SODIUM WIRING DIAGRAMS Wiring Diagram 1 Wiring Diagram 2 Wiring Diagram 9 Wiring Diagram 11 Wiring Diagram 36 Wiring Diagram 37 Wiring Diagram 3 Wiring Diagram 12 Wiring Diagram 4 Wiring Diagram 38 Wiring Diagram 26 Wiring Diagram 39 Wiring Diagram 5 Wiring Diagram 34 Wiring Diagram 40 Wiring Diagram 6 HID CORE & COIL Wiring Diagram 35 Wiring Diagram 41 PAGE 5-35 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) MH & HPS 50 HZ • 50 Hz • Minimum Starting Temperature: -40° C • CWA, Normal and High Power factor models available HID CORE & COIL BALLASTS 50 HERTZ Nom Dimensions Capacitor Ignitor UL Max Open Total Max Bench Input Catalog* Circuit Input Input Circuit Fuse Wir Ref Min Dry Film Oil Filled Wt. Catalog Dist. Top Volts Number Type Watts Curr. Volt. Rating Dia Dwg A B µF Volt Dia Ht Oval Ht (lbs.) Number lamp Rise (1) 175 WATT M57 METAL HALIDE LAMP 230 M175230AC3M CWA 205 1.17 312 2 14 PC1 2.25 3.55 12 400 1.56 3.74 1.5 3.13 6.7 n/a n/a C (1) 250 WATT M58 METAL HALIDE LAMP 230 M250230AC3M CWA 282 1.55 285 3 14 PC1 3.0 4.3 18 400 n/a n/a 2.01x3.01 3.1 9.0 n/a n/a D (1) 400 WATT M59 METAL HALIDE LAMP 230 M400230AC4M CWA 435 2.44 300 5 14 PC2 2.13 3.73 28 425 n/a n/a 1.91x2.91 3.9 13.0 n/a n/a D (1) 1000 WATT M47 METAL HALIDE LAMP 230 M1000230AC5M CWA 1080 5.33 405 15 14 PC3 3.44 5.24 30 440 n/a n/a 2.01x3.01 3.9 24.0 n/a n/a C (1) 1500 WATT M48 METAL HALIDE LAMP 230 M1500230AC5M CWA 1605 7.29 430 20 14 PC3 4.38 6.18 42(2x21) 480 n/a n/a 1.97x3.66 3.9 30 n/a n/a C (1) 200 WATT S66 HIGH PRESSURE SODIUM LAMP R-NPF 2.90 8 — — — — — — 240 225 240 1 4 1.5 3.0 5.4 HPS460-1B 10 D 1238-183S R-HPF 2.06 3 28 240 n/a n/a 1.91x2.91 3.1 (1) 250 WATT S50 HIGH PRESSURE SODIUM LAMP R-NPF 3.60 10 — — — — — — 230 278 230 1 4 2.0 3.5 7.1 HPS460-1B 10 A 1238-133S R-HPF 2.50 5 35 240 1.8 4.6 n/a n/a 230 S250230AC4M CWA 280 1.38 188 5 8 PC2 1.78 3.58 40 300 n/a n/a 2.01x3.01 3.9 10.3 HPS400-3A 3 B (1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP (continued) 230 S400230AC4M CWA 465 2.26 190 8 10 PC2 2.5 4.3 64 300 n/a n/a 1.91x2.91 3.1 15.5 HPS400-3A 3 D (1) 1000 WATT S52 HIGH PRESSURE SODIUM LAMP 230 S1000230AC5M CWA 1100 5.44 405 15 39 PC3 4.0 5.8 36 540 n/a n/a 1.96x3.65 4.25 25.5 HPS1000-4B 10 D HID CORE & COIL 50 HERTZ See page 5-37 for Reference Drawings and Wiring Diagrams. PAGE 5-36 HID CORE & COIL BALLASTS 50 HZ 50 HERTZ DESCRIPTION 2.625" SUFFIX * 0.438" For Ballast Only .199" Dia Thru For0.594" Capacitor Only (see pg. 5-5,4 Holes 5-6) .250" Dia Thru 0.438" B A 2.188" 2 Holes REFERENCE DRAWING PC1 000 A 500B REFERENCE DRAWING 4 0.656" .218" Dia Thru 4 Holes 0.199 Dia Thru 0.437" 4 Holes A A B MAX .250" Dia Thru 2 Holes 3.937" 3.500" 0.250 Dia Thru 2 Holes B A B 0.843" 0.812" 2.812˝ 2.937" 2.437" 2.438˝ 3.500" 3.938" Bracket To Lamp Shell e) 347V 277V A B 2 Holes Cleared for #10 Thru-Bolts 120V 3.875˝ 4 4.750" (Blue) 1 3 .250" Dia Thru 2 Holes A B STARTER 2 Four 0.250" Male Quick Connect Terminals To Lamp Shell (Yellow) 1.937" 0.625" .250" Dia Thru 8 Holes Lamp Eyelet 3 Com 3.875" 4.250" 4.375" 4.250˝ 4.375˝ 4.750˝ To Lamp Shell Com (Yellow) 3 A B MAX 2 3.875" 4.250" 1.937" 4 Holes Cleared for #10 Thru-Bolts (Black) Cap Cap Four 0.250" Male Quick Connect Terminals 2 Reference Drawing 4 3 REFERENCE DRAWING PC2 (Yellow) (Black) Cap Cap V 3.125" 3.750" Reference Drawing BRef. Dwg. L W M S 1 4.00” 0.75” 3.60” 0.25” 2, 3, 4 5.25” 1.75” 4.60” 0.25” 277V 0.637" PC1 5.25” 1.25” 4.60” 0.25” 0.637" Lamp Eyelet LampDia Eyelet 240V .250" Dia Thru .250" Thru 4 Holes (Blue) PC2 A 7.75” 1.25” 5.75” 0.25” 8 (Blue) Holes B 3 3 1 1 208V 3 3 .250" Dia Thru PC3 7.75” 2.75” 6.10” 0.25” .250" Dia Thru 2 Holes 2 Holes 120V STARTER See p. 5-8 for adjustable mounting brackets and detailed bracket drawings. STARTER (White) V S M Reference Drawing L 2 ference Drawing 1-A 3.125" .199" Dia Thru 4 Holes Cap W 2.500" Four 0.250" Male Quick Connect Blade Terminals 3.500˝ 3.938˝ Cap 3" Dia Thru 4 Holes 2.437" 1.218" 2.812" (Black) 1.218" (Yellow) 2.812" 3.875" 4.375" REFERENCE DRAWING PC3 5.750" 5.375" 4.250" 1.937" 4a 4.375" 5.375" 5.750" 0.250 Dia Thru 8 Holes Reference Drawing 6 Com White) (Yellow) Line Red to Lamp Eyelet Red to Lamp Eyelet 0.250 Dia Thru 2 Holes 1 3 3 3 0.625" .250" Dia Thru 8 Holes STARTER 0.687" .218" Dia Thru 4 Holes Com (White) or (Yellow) B 2A .250" Dia Thru 2 Holes 1.062" To Lamp Shell 7 2.750" 3.437" Com (White) or (Yellow) 3.437" 4.125" B 2 3.875˝ Red Lamp Shell B 8 3.875" 1.937" 4.375" 4.250" 1.937" 5.375" 4.375" 4.750" Wiring Diagram 10 240V Lamp Eyelet (Blue) Lamp Eyelet 120V A .250" Dia Thru 2 Holes 4.375˝ 5.375˝ 5.750˝ 5.750" Wiring Diagram 1 277V Reference Drawing 208V 14 0.625" .250" Dia Thru 4 Holes STARTER A Cap (White) 3.875" 4.250" 1 3 4.250˝ 3.437" WIRING DIAGRAMS Reference Drawing 8 B MAX (Red) 3 ) wn o (Br 1 d) (Re 3 STARTER Cap Cap (Red) (Red) 3 Reference Drawing 15 Reference Drawing 16 1 3 STARTER Line 2 e (Y Com Com (Yellow) (Yellow) Wiring Diagram 8 Com Com (White) (White) 12 Wiring Diagram 14 HID CORE & COIL 50 HERTZ ) w llo 2 Wiring Diagram 39 11 Line 347V Lamp Eyelet (Red) Blue/White Trace 3 277V 1 3 120V Cap STARTER Cap IGNITOR Line A Reference Drawing 7 (Blue) (Red) (Red) Cap (Red) 2 Com (White) Com (White) 15 Com (White) Yellow/Red Trace Cap (Red) Com (White) 16 PAGE 5-37 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) MH 35-400 WATT HID F-CAN F-CAN BALLASTS • 60 Hz • Minimum Starting Temperature: -30° C • CWA and High Power Factor Designs METAL HALIDE Nom Max Dimensions Max Open Dist Certifications Input Catalog Circuit Input Input Circuit Fuse Wir Overall Case Mtg Total To Sound Volts Number Type Watts Current Voltage Rating Dia Length Length Dim Weight Lamp (ft) Rating UL CSA (1) 35/39 WATT M130 METAL HALIDE (with built-in ignitor) 120 1120-251A-TC CWA 55 0.50 225 2 21 9.50 8.35 8.85 3.0 20 B Yes Yes (1) 50 WATT M110 METAL HALIDE (with built-in ignitor) 120 0.64 3 or 11210-236C-TC HX-HPF 70 240 20 11.75 10.56 11.14 11.0 20 B Yes Yes 277 0.65 2 (1) 70 WATT M85 METAL HALIDE (with built-in ignitor) 120 2.00 6 or 11210-277C-TC7 HX-HPF 98 250 20 11.75 10.56 11.14 11.0 20 B Yes Yes 277 0.90 3 (1) 70 WATT M98 METAL HALIDE (with built-in ignitor) 120 2.00 6 or 11210-506C-TC22 HX-HPF 90 250 20 11.75 10.56 11.14 11.0 20 B Yes Yes 277 0.90 3 120 2.00 6 or 11210-554C-TC HX-HPF 90 250 20 11.75 10.56 11.14 11.0 20 B No Yes 347 0.80 3 (1) 100 WATT M90 METAL HALIDE (with built-in ignitor) 120 2.20 8 or 11210-239C-TC HX-HPF 125 250 20 11.75 10.56 11.14 11.0 20 B Yes Yes 277 1.00 4 120 2.20 8 or 11210-606C-TC HX-HPF 125 250 20 11.75 10.56 11.14 11.0 20 B No Yes 347 0.70 2 (1) 150 WATT M81 METAL HALIDE (with built-in ignitor) 120 3.70 10 or 11210-242C-TC HX-HPF 185 260 20 14.31 13.19 13.75 14.0 20 B Yes Yes 277 1.60 5 (1) 150 WATT M102 METAL HALIDE (with built-in ignitor) 120 3.70 10 or 11210-539C-TC HX-HPF 185 260 20 14.31 13.19 13.75 14.0 20 B Yes Yes 277 1.60 4 (1) 175 WATT M57 METAL HALIDE LAMP 120 1.75 5 or 20 14.32 13.19 13.75 14.0 CWA 205 300 * B Yes Yes 1110-245SC-TC 0.75 3 277 120 1.75 5 or 20 11.75 10.55 11.10 14.0 CWA 205 300 * B Yes Yes 1110-564C-TC 0.62 2 347 (1) 250 WATT M58 METAL HALIDE LAMP 120 2.50 8 or 20 16.75 15.57 16.13 17.5 CWA 295 280 * C Yes Yes 1110-246C-TC 8c 1.10 4 277 120 2.50 8 or CWA 300 300 22 11.75 10.55 11.10 11.0 * B Yes Yes 1111-246C-TC 23 1.10 4 277 120 2.50 8 or 20 16.65 15.55 16.10 17.5 CWA 295 285 * C Yes Yes 1110-566C-TC 0.95 3 347 (1) 400 WATT M59 METAL HALIDE LAMP 120 3.90 10 or 20 19.25 18.06 18.63 23.0 CWA 455 300 * C Yes Yes 1110-247SC-TC 1.70 5 277 120 3.90 10 or 1111-247SC-TC 23 CWA 460 300 22 14.31 13.19 13.75 14.0 * B Yes Yes 1.70 5 277 120 3.90 10 or 20 19.25 18.05 18.60 23.0 CWA 460 300 * C Yes Yes 1110-568C-TC 1.30 5 347 This ballast may also be used with (1) 70 watt S88 High Pressure Sodium lamp. 7 M98 Designates Venture Lighting catalog numbers MH70/4/MED, C/4/MED or MS70/C/84/MED/W 22 See page 5-40 for Reference Drawings and Wiring Diagrams. This ballast can be used with a MH200 ignitor to operate (1) 250 watt M103 lamp. Consult Universal for instructions. 8c 23 Two of these ballasts are required to operate the lamp. Electrical data is for two ballasts, except for “Sound Rating,” which is for each ballast * Refer to Page 5-5. PAGE 5-38 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) F-CAN BALLASTS HIGH PRESSUE SODIUM HPS 35-250 • 60 Hz • Minimum Starting Temperature: -40° C • CWA and High Power Factor Designs WATT Nom Max Dimensions Max Open Dist Certifications Input Catalog Circuit Input Input Circuit Fuse Wir Overall Case Mtg Total To Sound Volts Number Type Watts Current Voltage Rating Dia Length Length Dim Weight Lamp (ft) Rating UL CSA (1) 35 WATT S76 HIGH PRESSURE SODIUM (with built-in starter) 120 0.80 5 or 12210-261C-TC 20 11.75 10.55 11.10 9.0 HX-HPF 55 120 10 B Yes Yes 0.35 2 277 (1) 50 WATT S68 HIGH PRESSURE SODIUM (with built-in starter) 120 1.40 5 or 12210-236C-TC 20 11.75 10.55 11.10 9.0 HX-HPF 75 120 10 B Yes Yes 0.60 2 277 (1) 70 WATT S62 HIGH PRESSURE SODIUM (with built-in starter) 120 1.60 5 or 12210-237C-TC 20 11.75 10.56 11.14 9.15 HX-HPF 97 140 10 B Yes Yes 0.70 2 277 120 1.69 5 or 12210-552C-TC 20 11.75 10.55 11.10 9.2 HX-HPF 109 145 10 B Yes Yes 0.63 2 347 (1) 100 WATT S54 HIGH PRESSURE SODIUM (with built-in starter) 120 2.10 6 or 12210-239C-TC 20 11.75 10.55 11.10 10.4 HX-HPF 125 130 10 B Yes Yes 1.00 3 277 120 2.10 6 or 12210-606C-TC 20 11.75 10.55 11.10 10.4 HX-HPF 126 165 10 B Yes Yes 0.90 3 347 (1) 150 WATT S55 HIGH PRESSURE SODIUM (with built-in starter) 120 2.80 8 or 12210-241C-TC 20 14.30 13.15 13.75 14.1 HX-HPF 185 120 10 B Yes Yes 1.20 4 277 120 2.80 8 or 12210-602C-TC 20 14.30 13.15 13.75 14.1 HX-HPF 185 120 10 B Yes Yes 1.03 3 347 See page 5-40 for Reference Drawings and Wiring Diagrams. HID F-CAN PAGE 5-39 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Insulate Unused Input Lead for 300 Volts. White or Yellow Wiring Diagram 36 277V Black or 120V Black/Yellow F-CAN 277V or 347V Black or 120V Black/Yellow Wiring Diagram B 34 A B A L L A S T BALLAST Red Black White 1.000" 2.000" Line Insulate Unused Input Lead for 300 Volts. L L A S T 0.250" Dia. Red Red White 4.000" 4.500" 277V White or Yellow B A L L A S T Wiring Diagram 35 Separately Insulate Unused Input Lead for 300 Volts Wiring Diagram HID CORE & COIL BALLASTS 36 Red F-CAN Black or Yellow 0.406" Black or 120V 0.562" 0.250" Black/Yellow Dia. Wiring Diagram 34 Separately Insulate Unused Input 1.000" Lead for 3002.000" Volts Wiring Diagram 35 Wiring Diagram Mounting Bracket Assemblies 4.500" 0.406" 4.000" 36 F-CAN BALLASTS OPTIONAL ACCESSORIES Mounting Bracket Assemblies Splice Box Mounting Bracket Assemblies Tee-Pee Lead Wire Covers 1.437" 1.500" 2.562" 2.000" 0.250" Dia. 0.562" 1.750" 0.218" Dia. 1.000" 2.000" 2.531" 1.437" 0.406" 4.000" 4.500" Tee-Pee Lead Wire Covers 1.500" 2.562" 2.000" 0.562" Embossed Dimples 2 Places 2.000" 3.000" 1.750" 2.812" 0.850" Dia. Knockouts 5 Places 0.218" Dia. Catalog Number 2-BMB-1. Mounting Bracket Assemblies Catalog NumberTee-Pee TP5. Ref.part Lead #001-2013. Wire Covers Available for the remote installation of ballasts. Each assembly consists of two (2) mounting brackets, four (4) screws, four (4) washers and four (4) nuts. For use where ballast is attached to the surface of an enclosure or raceway. Embossed Dimples 2 Places 1.437" 1.500" 2.562" 2.000" 2.531" 0.297" Dia. Mounting Holes 2 Places Box Catalog Number SB-4. Splice Ref. part #001-2009 2.000" 3.000" 2.812" 0.850" Dia. Knockouts 5 Places For use with all F-Can Ballasts. It is easily installed on 0.297" Dia. the anchor bracket provided on each F-Can ballast. It Mounting Holes contains five (5) 7/8” diameter knockouts. 2 Places Splice Box 1.750" 0.218" Dia. 2.531" REFERENCE DRAWING Tee-Pee Lead Wire Covers FOR F-CAN e as Embossed Dimples 2 Places 2.000" 3.000" 0.850" Dia. Knockouts 5 Places 0.297" Dia. Mounting Holes 2 Places th ng Le 2.812" Height C Width Splice Box g tin ngth un e Mo rall L e Ov Hole Mounting Width WIRING DIAGRAMS B A Wiring Diagram 20 L L A S T Black L L A S T Red Line HID F-CAN B A L L A S T Red White White or Yellow 120V Black 277V Black or 120V Black/Yellow Wiring Diagram 35 Red White LAST B A Wiring Diagram 21 Wiring Diagram 22 Black or Yellow Red Separately Neutral toInsulate Lamp ShellUnused Input Lead for 300 Volts Wiring Diagram 36 1.000" 2.000" 0.406" 0.562" PAGE 5-40 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) STANDARD IGNITORS • INSTANT RESTRIKE IGNITORS • LONG DISTANCE IGNITORS • AUTOMATIC SHUTOFF IGNITORS • SHUTOFF DEVICES Catalog Number IGNITORS Description Reference Drawing Number --STANDARD IGNITORS (See pg. 5-43) PULSE START METAL HALIDE MH 70-3B 13 MH 100-3A MH 150-1A MH 200-1B 13 MH 350-1A P 750-1B13 HPS 1000-4B13 HIGH PRESSURE SODIUM HPS 150-3A HPS 400-3A HPS 450-1B 13 HPS 460-1B 13 HPS 600-1B HPS 610-1B HPS 1000-4B 13 HPS 1000-6B 13 For double-ended MH lamps with HX-HPF ballasts: 70 watt (M85), 100 watt (M91), and 150 watt (M81) 27 For MH lamps with HX-HPF ballasts: 35/39w(M130), 50w(M110), 70w(M98), 100w(M90/M140), and 150w(M102/M142) 25 For 150 watt (M102/M142) lamp with CWA ballast 28 For double-ended MH 250 watt (M80) lamp 28 For MH lamps with CWA ballasts: 175 watt (M152/M137), 200 watt (M136), 250 watt (M153/M138), 320 watt (M154/M132), 350 watt (M131), 400 watt (M155/M135), and 450 watt (M144) 24 For 750 watt (M149) MH lamp 28 For MH lamps: 875 watt (M166) and 1000 watt (M141). It is also used for 1000W HPS lamps 28 For HPS lamps of 150 watt or less with HX-HPF ballast, except 150 watt S56 lamp For HPS lamps from 200 to 400 watts and 150 watt S56 lamp with CWA ballasts For 150 watt S56, 200, 250 or 400 watt lamps with 240 volt/60 Hz reactor ballasts. With attached mounting bracket. For 200, 250 and 400 watt lamps with HX-HPF ballasts and 50 Hz reactor ballasts. With attached mounting bracket. For 600 watt lamps. For 600 watt lamps. For 1000 watt HPS and Pulse Start Metal Halide lamps. With attached mounting bracket. Obsolete 24 25 28 28 28 27 27 27 PLUG REPLACEABLE IGNITORS PULSE START METAL HALIDE MH 150-G15 MH 350-G05 HIGH PRESSURE SODIUM HPS 150-G01 HPS 400-G05 For MH lamps with HX-HPF ballasts: 35/39 watt (M130), 50 watt (M110), 70 watt (M98), 100 watt (M90/M140), and 150 watt (M102/M142) 32 For MH lamps with CWA ballasts: 175 watt (M152/M137), 200 watt (M136), 250 watt (M153/M138), 320 watt (M154/M132), 350 watt (M131), 400 watt (M155/M135), and 450 watt (M144) 32 For HPS lamps of 150 watt or less with HX-HPF ballast, except 150 watt S56 lamp For HPS lamps from 200 to 400 watts and 150 watt S56 lamp with CWA ballasts 32 32 INSTANT RESTRIKE IGNITORS HIGH PRESSURE SODIUM HPS 150-5B 13 Instant Restrike Ignitor — for lamps of 150 watts or less except 150 watt S56. Ignitor has attached mounting bracket. 30 LONG DISTANCE IGNITORS PULSE START METAL HALIDE MH 100-5A MH 100-5A MH UNV-5B HIGH PRESSURE SODIUM HPS 150-4A HPS 400-4A HPS 1000-5B For MH lamps from 35 to 50 watts. Max Ballast to Lamp Distance ( ~ 20’) For MH lamps from 70 to 150 watts. Max Ballast to Lamp Distance ( ~ 30’) For MH lamps from 35 to 450 watts. Ignitor incorporates automatic resetting thermal protection. Max Ballast to Lamp Distance ( ~ 50’) 25 25 25 For HPS lamps of 150 watt or less, excerpt 150 watt S56 lamp. Max Ballast to Lamp Distance ( ~ 20’) 24 For HPS lamps from 200 to 400 watts and 150 watt S56 lamp. Max Ballast to Lamp Distance ( ~ 25’) 25 For 1000 watt HPS lamps. Ignitor incorporates automatic resetting thermal protection. Max Ballast to Lamp Distance ( ~ 50’) 25 AUTOMATIC SHUTOFF IGNITORS PULSE START METAL HALIDE MH 150-35B MH 350-15B 13 13 P 750-15B 13 HPS 1000-55B 13 HIGH PRESSURE SODIUM HPS 150-45B 13 HPS 400-45B 13 HPS 1000-55B 13 For MH lamps: 35/39 watt (M130), 50 watt (M110), 70 watt (M98), 100 watt (M90/M140), and 150 watt (M102/M142). With attached mounting bracket For 150 watt M81 lamp with CWA ballasts. With attached mounting bracket. For MH lamps: 175 watt (M152/M137), 200 watt (M136), 250 watt (M153/M138), 320 watt (M154/M132), 350 watt (M131), 400 watt (M155/M135), and 450 watt (M144) For 750 watt (M149) MH lamp For MH lamps: 875 watt (M166) and 1000 watt (M141). It is also used for 1000W HPS lamps For lamps of 150 watts or less except 150 watt S56. With attached mounting bracket. For lamps from 200 to 400 watts and 150 watt S56 with constant wattage autotransformer ballasts. With attached mounting bracket. For 1000 watt HPS and Pulse Start Metal Halide lamps. With attached mounting bracket. AUTOMATIC SHUTOFF DEVICES In addition to one-piece shutoff ignitors, automatic shutoff devices are available as separate components for use with the ignitors below. SA-55 SA-100 SA-250 13 HPS 150-3A, HPS 150-5B MH70-3B, MH100-3A, MH150-1A, MH350-1A, HPS150-4A, HPS400-3A, HPS600-1B HPS1000-4B ignitor, only with 1000 watt HPS ballasts 28 31 31 31 31 28 28 31 25 25 33 May also be available without attached mounting bracket. Substitute “A” suffix for “B” suffix when ordering. Minimum quantities may apply. PAGE 5-41 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID IGNITORS MH 100-35B 13 IGNITORS IGNITORS Lamp Watts ANSI Code Circuit Type Standard Ignitors Auto Shutoff Instant Restrike Long Distance Ignitors Lamp Watts HPS 150-45B HPS 150-45B HPS 150-45B HPS 150-45B HPS 150-45B HPS 400-45B HPS 400-45B HPS 400-45B HPS 400-45B HPS 400-45B HPS 400-45B HPS 400-45B — — HPS 1000-55B HPS 150-5B HPS 150-5B HPS 150-5B HPS 150-5B HPS 150-5B — — — — — — — — — — HPS 150-4A HPS 150-4A HPS 150-4A HPS 150-4A HPS 150-4A HPS 400-4A HPS 400-4A HPS 400-4A HPS 400-4A HPS 400-4A HPS 400-4A HPS 400-4A — — — 35 50 70 70 100 100 100 150 150 150 350 350 HIGH PRESSURE SODIUM IGNITORS HID IGNITORS 35 50 70 100 150 150 250 250 250 400 400 400 600 600 1000 S76 S68 S62 S54 S55 S56 S50 S50 S50 S51 S51 S51 S106 S106 S52 Reactor Reactor, HX Reactor, HX Reactor, HX Reactor, HX CWA Reactor CWA HX Reactor CWA HX CWA Reactor CWA HPS 150-3A HPS 150-3A HPS 150-3A HPS 150-3A HPS 150-3A HPS 400-3A HPS 450-1B HPS 400-3A HPS 460-1B HPS 450-1B HPS 400-3A HPS 460-1B HPS 600-1B HPS 610-1B HPS 1000-4B ANSI Code Circuit Type Standard Ignitors Auto Shutoff Long Distance Ignitors MH 100-3A MH 100-3A MH 70-3B MH 100-3A MH 100-3A MH 100-3A MH 70-3B MH 70-3B MH 150-35B MH 100-3A MH 70-3B MH 70-3B — — MH 70-35B MH 100-35B MH 100-35B MH 100-35B — — MH 150-35B MH 100-35B — — MH 100-5A MH 100-5A MH 100-5A MH 100-5A MH 100-5A MH 100-5A — — — MH 100-5A — — METAL HALIDE IGNITORS M130 M110 M85 M98 M90 M90 M91 M81 M81 M102 M131 M131 Reactor HX HX HX Reactor CWA HX HX CWA HX Reactor HX STANDARD IGNITORS LONG DISTANCE IGNITORS Standard Ignitors are supplied with all Universal High Pressure Sodium and Metal Halide ballasts requiring ignitors. These ballasts are supplied with an appropriate external ignitor unless the ignitor is permanently attached to or built into the ballast. Long Distance Ignitors are used in situations where a ignitor must be mounted further from the lamp than is recommended for a standard ignitor. The maximum lamp to ignitor distance for these ignitors is 50 feet, which may vary depending on the type of lamp, ballast, fixture, and wiring. INSTANT RESTRIKE IGNITORS AUTOMATIC SHUTOFF IGNITORS An Instant Restrike Ignitor generates multiple pulses to restrike a lamp arc after a brief power interruption has extinguished it, without the typical 3-minute cool-down time. A Standard Ignitor cannot restrike an arc until the lamp has had time to sufficiently cool. Even though an Instant Restrike Ignitor can reinitiate the lamp arc immediately upon restoration of power, the lamp is still subject to warmup. The following chart is based on an S55 lamp. In the event of a lamp failure, a Standard Ignitor will continue to pulse, trying to start the lamp. This may reduce the life of the ignitor. An Automatic Shutoff Ignitor will apply pulses for 10 to 12 minutes and then deactivate if a lamp arc cannot be initiated. Resetting the ignitor is accomplished by momentarily interrupting the power to the ballast. For this reason, these ignitors are not recommended for use on unswitched circuits. Time Lamp Is Extinguished Restrike Time 1 second 5 seconds 15 seconds 30 seconds 1 minute Cold Start 2 seconds Instant Instant Instant Instant Instant Light Output On Reignition 87% 83% 76% 62% 46% 36% SHUTOFF DEVICES Lamp Warmup Time Ignitor Accessory (IA) devices can be used to convert a Standard Ignitor into an Automatic Shutoff Ignitor. Simply match the Shutoff Device catalog number on page 5-62 with the Standard Ignitor that is supplied with the ballast. Using the IA device with the Standard Ignitor eliminates the need to buy a separate Automatic Shutoff Ignitor. 35 seconds 70 seconds 130 seconds 190 seconds 255 seconds 360 seconds TEMPERATURE RATING PLUG REPACEABLE IGNITORS Most ignitors are rated for a 105°C maximum case temperature. Consult ballast specification sheets at www.unvlt.com for specific details. Incorporates terminals and a separate mounting base to simplify construction and replacement. PAGE 5-42 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) 0.750" 2.500" ng .219 Dia. Thru 1.250" REFERENCE DRAWINGS Starter Reference Drawing 26 All dimensions in decimals. All lead lengths: 13 inches ±1 Starter Reference Drawing 25 Sta No. 1 (Red or Blue) No. 1 (Red or Blue) No. 3 (Brown) Ref. Drawing 24 Ref. Drawing 25 No. 3 (Brown) No. 2 (Yellow) No. 2 (Yellow) Mounting Bracket No. 1 (Red or Blue) No. 1 (Red or Blue) No. 3 (Brown) No. 3 (Brown) 1.312" No. 2 (Yellow) No. 2 (Yellow) No. 1 (Red or Blue) No. 1 (Red or Blue) No. 3 (Brown) No. 3 (Brown) No. 2 (Yellow) No. 2 (Yellow) Mounting Bracket 1.312" No. 1.250" 1 (Red or Blue) No. 3 (Brown) No. 2 (Yellow)2.031" ing ing n) 2.031" 2.031" 0.875" 0.218" e Drawing w) e/White) d or Blue) )wn) racket ow) No. 2 (Yellow) No. 1 (Red or Blue) Mounting Bracket No. 3 (Brown) No. 2 (Yellow) 1.312" 1.265" Mounting Bracket 1.265" 0.500" 1.250"0.500" 1.312" 2.031" 0.750" 0.750" 1.250" .219 Dia. Thru 0.875" .219 Dia. Thru 2.031" 3.500" No. 2 (Yellow) 1.250" Bracket 3.500" 4.312" 4.750" 4.312" Starter Reference Drawing 29 No. 1 (Red or Blue) Reference Drawing No. 1 (Red or Blue) Ref. Drawing Starter 31 No. 3 (Brown) 27 No. 3 (Brown) 1.250" e Drawing ce Drawing low) ue/White) e) Bracket 0.875" 2.531" 3.500" 4.312" 2.031" 0.875" 0.218" 4.750" 0.875" 0.218" Ballast (Blue/White) Lamp (Blue) Mounting Bracket 1.562" 1.500" 0.875" 2.500" 0.218" 0.875" 3.500" 4.312" 4.750" .218" No. 1 (Red or Blue) No. 1 (Red or Blue) No. 3 (Brown) No. 3 (Brown) No. 2 (Yellow) No. 2 (Yellow) Mounting Bracket Mounting Bracket Ref. Drawing 32 1.312" 1.250" 2.031" 3.500" 4.312" 4.750" 3.500" 4.312" 4.750" Starter Reference Drawing 30 1.250" 0.875" 0.218" 2.031" 0.875" 0.218" 0.218" 4.750" Starter Reference Drawing Starter Reference Drawing 28 28 Starter Reference Drawing Starter Reference Drawing 31 29 Com. (Yellow) Starter Reference Drawing Starter Reference Drawing 29 29 Ballast (Blue/White) Ballast (Blue/White) Lamp (Blue) Lamp (Blue) Com. (Yellow) Com. (Yellow) Mounting Bracket Mounting Bracket Com. (Yellow) Ballast (Blue/White) Ballast (Blue/White) Lamp (Blue) Lamp (Blue) Mounting Bracket Ballast (Blue/White) Mounting Bracket Lamp (Blue) 1.562" 1.562" Com. (Yellow) 1.562" Mounting Bracket 1.500" 1.500" 1.562" 3.500" 1.531" 3.500" 2.500" 0.875" 1.531" 2.500" PAGE 5-43 3.750" 1.562" 1.531" 2.531" 0.875" 3.750" St Ref. Drawing 33 1.312" 2.031" 0.875" 0.218" 0.218" HID IGNITORS 0.218" 3.500" 4.312" 3.750" 4.750" 4.312" 3.500" 4.750" 4.312" Com. (Yellow) Starter Reference Drawing Starter Reference Drawing 27 27 Mounting Bracket 1.250" 1.562" 1.250" 2.500" Ref. Drawing 30 .875" Ballast (Blue/White) No. 2 (Yellow) No. 2 (Yellow) Lamp (Blue) Bracket No. 1Mounting (Red or Mounting Blue) Bracket Com. No. 3(Yellow) (Brown) 1.312" 1.312" Mounting Bracket No. 2 (Yellow) 2.031" 0.218" 2.057" St 2.031" 0.875" 1.25" 3.500" 4.312" 4.750" 3.46" 4.312" 4.750" 4.750" 1.312" 1.531" 0.875" 0.218" 0.218" Starter Reference Drawing 28 1.250" 2.031" 1.312" 0.218" Starter Drawing 0.875" 4.750" Reference Starter Reference Drawing 3.500" 26 26 4.312" Bracket 2.031" 0.875" No. 1 (Red or Blue) No. 1 (Red or Blue) No. 3 (Brown) No. 3 (Brown) No. 2 (Yellow) No. 2 (Yellow) 120V (Black/Yellow) Mounting Bracket Mounting Bracket No. 1 (Blue) 1.312" 1.312" No. 3 (Brown) Ref. Drawing 28 0.218" wing 3.500" 4.312" 4.750" Starter Reference Drawing Starter Reference Drawing 25 25 No. 3 (Brown) racket 0.875" 1.250" 1.250" Starter Reference Drawing Starter Reference Drawing Starter Reference 24 24 Drawing 27 Starter Reference Drawing No. 1 (Red or Blue) 25 Ref. Drawing 27 w) 2.500" 1.250" 2.500" 0.218" 2.500" or Blue) 1.250" 0.875" 1.250" 1.250" 3.500" 2.000" 2.000" 4.312" 4.750" IGNITORS 0.875" 2.531" 0.875" FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID Notes PAGE 5-44 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) eHID Less energy. Enhanced performances. Experience significant energy savings and increased lumen output vs. halogen lamps with Electronic High Intensity Discharge (HID) ballasts from Universal Lighting Technologies. Vossloh-Schwabe (VS), also a Panasonic Lighting Company, recently merged its US operation into Universal. This merger combines Vossloh’s market leading high quality electronic HID product line with Universal’s extensive offering. There are numerous advantages of using VS electronic HID ballasts. Operating HID lamps used in HID lighting systems with electronic ballasts greatly increases system efficiency in comparison with magnetic ballasts. These ballasts are designed to provide optimal lamp performance and maximum energy savings. With enhanced capabilities to downsize the form factor of luminaire housings and reduce wiring costs, VS electronic HID ballasts lead the way to electronic solutions for HID lighting. Microprocessor controlled intelligence offers superior lamp performance and the flexibility for proprietary value-added functions. VS electronic HID ballasts cover your HID needs with products for Metal Halide Lamps ranging from 20 Watts to 250 Watts. VS electronic HID ballasts continuously monitors lamp characteristics during operation and adjusts the lamp current to optimize performance. This guarantees controlled operation in all modes of operation. The lamp color temperature is also stabilized by using VS electronic HID ballasts due to its relatively constant output power characteristics in addition to producing flicker free lighting that usually occurs at the end of the discharge lamp’s service life. The technology enhancements of VS electronic HID ballasts, allowing very small form factors and light weight designs, has enabled new, innovative luminaire designs. ELECTRONIC HID Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group Product Overview Micro Series: The introduction of the smallest eHID ballasts in the market was coordinated with the launch of the new miniaturized capsule MH lamps enabling the ultimate luminaire design flexibility. Extremely compact and aesthetically pleasing, luminaire designs are approaching the form factor and size of low voltage halogen systems. Mini Ballast Series: Two ideal form factors that are used in millions of HID track light luminaires characterize the mini series of eHID ballasts. The mini-slim and mini-square units revolutionized track lighting by allowing significantly smaller and greater variety of luminaire designs while providing energy savings of 60-70% versus halogen systems. ELECTRONIC HID Standard Case “Valued-added Series”: Millions of recessed, track-head and specialty luminaires have used the de facto industry standard enclosure since introduction. The significant energy savings and enhanced reliability of our ballasts promoted the rapid escalation of electronically ballasted MH luminaires for almost 15 years. Technological advancements have now allowed the integration of multiple, value-added functions such as: a powersource for the self-heating thermal protectors, an electronic 277V step-down transformer, and an intelligent auxiliary lighting control for back-up lighting during lamp hot restrike modes. Ideal for new, retrofit and replacement applications in recessed luminaires. Features and Benefits: • Optimum lamp performance • Rugged, compact and lightweight design • High power factor • Enhanced color and CRI uniformity • Shut-down protection • Reduced wiring costs • Eliminates nuisance lamp cycling at end-of-lamp life (intelligent lamp sensing capabilities) • Constant lamp power • Reduced lamp dropouts due to improved line voltage dip withstand • Quiet operation • Durable performance for various applications • Fewer SKUs required in inventory • Broadens design flexibility for new applications and luminaries PAGE 6-2 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) eHID Product Family Order code Part # Lamp Wattage Lamp Type Input Voltage Mounting Lead Exit Dimensions Wiring Micro Series 188514 M2012CK-7EUN 20 M/C156 120 No Feet Side 1 1 188882 M2012CK-7EUN-F 20 M/C156 120 Feet Side 2 1 1 188883 M2012CK-7EUN-J 20 M/C156 120 Studs Top 3 188574 M2212CK-7EUN 22 M/C175 120 No Feet Side 1 1 188884 M2212CK-7EUN-F 22 M/C175 120 Feet Side 2 1 1 188885 M2212CK-7EUN-J 22 M/C175 120 Studs Top 3 188635 M3912CK-7EUN 39 M/C130 120 No Feet Side 4 1 188776 M3912CK-7EUN-F 39 M/C130 120 Feet Side 2 1 1 188756 M3912CK-7EUN-J 39 M/C130 120 Studs Top 3 188757 MTm3912CK-7EUN 39Tm M/C179 120 No Feet Side 4 1 188777 MTm3912CK-7EUN-F 39Tm M/C179 120 Feet Side 2 1 188758 MTm3912CK-7EUN-J 39Tm M/C179 120 Studs Top 3 1 Mini-Slim Series 188152 M2012CK-6EUN-F 20 M/C156 120 Feet Side 5 1 188246 M3912CK-6EUN-F 39 M/C130 120 Feet Side 5 1 188702 M3927CK-6EUN-F 39 M/C130 277 Feet Side 6 1 188774 M3927CK-6EUN-J 39 M/C130 277 Studs Top 7 1 188164 M7012CK-6EUN-F 70 M/C98, M/C139, M/C143 120 Feet Side 5 1 188703 M7027CK-6EUN-F 70 M/C98, M/C139, M/C143 277 Feet Side 6 1 188775 M7027CK-6EUN-J 70 M/C98, M/C139, M/C143 277 Studs Top 7 1 Mini-Square Series 188151 M2012CK-6EU-F 20 M/C156 120 Feet Side 8 1 188627 M2012CK-6EU-J 20 M/C156 120 Studs Top 9 1 188701 M2212CK-6EU-J 22 M/C175 120 Studs Top 9 1 188293 M3912CK-6EU-F 39 M/C130 120 Feet Side 8 1 1 188512 M3912CK-6EU-J 39 M/C130 120 Studs Top 9 188402 M3927CK-6EU-F 39 M/C130 277 Feet Side 10 1 188551 M3927CK-6EU-J 39 M/C130 277 Studs Top 9 1 188377 JM7012CK-6EU-F 70 M/C98, M/C139, M/C143 120 Feet Side 11 1 188628 M7012CK-6EU-J 70 M/C98, M/C139, M/C143 120 Studs Top 9 1 188895 M3912-27CK-6EU-F 39 M/C130 120-277 Feet Side 10 1 188896 M3912-27CK-6EU-J 39 M/C130 120-277 Studs Top 9 1 188897 M3912/27CK-6EU-JT3 39 M/C130 120/277 Studs Top 9 2a,2b,2c 188901 M2012-27CK-6EU-F 20 M/C156 120-277 Feet Side 10 1 188902 M2012-27CK-6EU-J 20 M/C156 120-277 Studs Top 9 1 188903 M2012/27CK-6EU-JT3 20 M/C156 120/277 Studs Top 9 2a,2b,2c 188939 M7012-27CK-6EU-F 70 M/C198,M/C139,M/C143 120-277 Feet Side 10 1 188940 M7012-27CK-6EU-J 70 M/C198,M/C139,M/C143 120-277 Studs Top 9 1 188941 M7012/27CK-6EU-JT3 70 M/C198,M/C139,M/C143 120/277 Studs Top 9 2a,2b,2c Standard Series 188610 M2012-27CK-5EU-F 20 M/C156 120-277 Feet Side 12 1 188611 M2012/27CK-5EU-JT3 20 M/C156 120/277 Studs Top 13 2a, 2b, 2c 188156 M3912-27CK-5EU 39 M/C130 120-277 No Feet Side 14 1 188157 M3912-27CK-5EU-F 39 M/C130 120-277 Feet Side 12 1 188301 M3912-27CK-5EU-J 39 M/C130 120-277 Studs Top 13 1 188629 M3912/27CK-5EU-JT3 39 M/C130 120/277 Studs Top 13 2a, 2b, 2c 188630 M3912/27CK-5EU-JA3 39 M/C130 120/277 Studs Top 13 3a, 3b, 3c 188612 M5012-27CK-5EU-F 50 M148 or M110 120-277 Feet Side 12 1 188613 M5012/27CK-5EU-JT3 50 M148 or M110 120/277 Studs Top 13 2a, 2b, 2c M7012-27CK-5EU 70 M/C98, M/C139, M/C143 120-277 No Feet Side 14 1 M7012-27CK-5EU-F 70 M/C98, M/C139, M/C143 120-277 Feet Side 12 1 188167 M7012-27CK-5EU-J 70 M/C98, M/C139, M/C143 120-277 Studs Top 13 1 188631 M7012/27CK-5EU-JT3 70 M/C98, M/C139, M/C143 120/277 Studs Top 13 2a, 2b, 2c 188632 M7012/27CK-5EU-JA3 70 M/C98, M/C139, M/C143 120/277 Studs Top 13 3a, 3b, 3c 188633 M10012/27CK-5EU-JT3 100 M/C90, M/C140 and M/C164 120/277 Studs Top 13 2a, 2b, 2c 188168 M10012-27CK-5EU 100 M/C90, M/C140 and M/C164 120-277 No Feet Side 14 1 188169 M10012-27CK-5EU-F 100 M/C90, M/C140 and M/C164 120-277 Feet Side 12 1 188302 M10012-27CK-5EU-J 100 M/C90, M/C140 and M/C164 120-277 Studs Top 13 1 188634 M10012/27CK-5EU-JA3 100 M/C90, M/C140 and M/C164 120/277 Studs Top 13 3a, 3b, 3c 188638 M15012-27CK-5EU-F 150 M/C102/E and M/C142/E 120-277 Feet Side 12 1 188639 M15012-27CK-5EU-J 150 M/C102/E and M/C142/E 120-277 Studs Top 13 1 C183 208-277 Feet Side 17 4a, 4b M80/M168 208-277 Feet Side 17 4a, 4b Mid Wattage 188909 M21020-27CK-2EUN-F 210 188911 M25020-27CK-2EUN-F 250 (100V) PAGE 6-3 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) ELECTRONIC HID 188165 188166 Wiring Diagrams 1 N WHITE 120V RED L 1 BLACK BLUE GREEN 120/277V with IDTP Tap 2b WIRING (with 3-wire 120V IDTP) WIRING (with 4-wire 120V IDTP) RP-1B IDTP 2 black L blue N WHITE black 120/277 white 120/277 N WHITE PURPLE blue white L RP-5A IDTP 2 red 2a PURPLE BLACK BLACK GREEN GREEN RED RED 1 BLUE 1 BLUE 2c WIRING (with 3-wire 277V IDTP) RP-4A IDTP 2 L 277 N red white black WHITE PURPLE BLACK GREEN RED 1 BLUE 120/277V with Auxiliary Control + IDTP Tap Wiring & Dimensions Diagrams (shown in millimeters and inches) 3b WIRING (with 3-wire 120V IDTP) WIRING (with 4-wire 120V IDTP) RP-1B IDTP 2 N WHITE HALOGEN LAMP <150W L blue white black 120/277 black 120/277 N ORANGE PURPLE WHITE BLACK GREEN GREEN RED RED 1 Connect red lead to center contact on Edison base lampholders 2 IDTP - Insulation Detector Thermal Protector 1 BLUE Notes for Wiring Diagram 1 blue ORANGE PURPLE BLACK BLUE ELECTRONIC HID HALOGEN LAMP <150W red L RP-5A IDTP 2 white 3a 3c WIRING (with 3-wire 277V IDTP) RP-4A IDTP 2 L black 277 N WHITE HALOGEN LAMP <150W red white ORANGE PURPLE BLACK GREEN RED 1 BLUE PAGE 6-4 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Wiring Dimming Ballasts 4a 4b WIRING (For Fixed Output) WIRING (For Dimming Control) RED RED BLUE BLUE GREEN GREEN BLACK BLACK WHITE WHITE GREY (+) GREY (+) PINK (+) PINK (+) 0 - 10V DIMMER Dimensions 1 2 33.5/1.32 29.7/1.17 33.0/1.30 97.7/3.85 76.0/2.99 Temp. Testpoint 31.0/1.22 28.0/1.10 Temp. Testpoint 104.7/4.12 3 4 33.5/1.32 16.7/0.66 33.5/1.35 96.7/3.81 90.7/3.57 Temp. Testpoint 38.1/1.5 Temp. Testpoint 11.8/0.47 8-32 stud 50.8/2.0 PAGE 6-4 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) ELECTRONIC HID 30.1/1.19 Dimensions 5 6 28.6/ 44.2/ 1.13 1.74 28.6/ 44.2/ 1.13 1.74 133/5.25 133/5.25 140..0/5.51 140.0/5.51 30.0/1.18 30.0/1.18 7 8 44.2/ 1.74 64.8/2.55 75.6/2.98 22.1/ 0.87 127.8/5.03 50.8/2 86.8/3.42 10.9/0.43 95.1/3.74 39.5/ 1.56 Temp. Testpoint 9 30.6/1.21 10 76.2/3.0 64.8/2.55 75.6/2.98 38.1/1.5 86.8/3.42 89.4/3.52 95.1/3.74 50.8/2.0 11.8/0.47 8-32 stud 30.6/1.21 39.7/1.56 ELECTRONIC HID 11 12 64.8/2.55 72.1/ 2.84 76.0/2.99 92.0/ 3.62 46.0/ 1.31 86.8/3.42 133.5/5.26 95.1/3.74 140.0/5.51 39.9/1.57 31.8/1.25 PAGE 6-5 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Dimensions 13 14 92.0/3.62 92.0/ 3.62 46.0/1.31 127.5/5.02 8-32 stud 133.5/5.26 50.8/2.0 11.4/0.45 39.9/1.57 39.9/1.57 15 16 92.0/3.62 72.1/ 2.84 92.0/ 3.62 46.0/ 1.31 46.0/1.31 127.5/5.02 8-32 stud 133.5/5.26 50.8/2.0 140.0/5.51 11.4/0.45 39.9/1.57 39.9/1.57 17 72.0/ 2.84 92.0/ 3.62 46.0/ 1.31 202.0/ 7.95 208.0/ 8.19 60.0/2.36 ELECTRONIC HID PAGE 6-6 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Application And Operating Information General: If the electrical current through an HID lamp is properly stabilized, an HID plasma arc with very high luminous efficiency is created in the arc tube chamber resulting in a very efficient light source. The internal pressure of the arc tube chamber rises as the arc tube temperature increases and will attain between 1 and 10 bar; thereby, defining these lamps as high-pressure HID lamps, high intensity discharge lamps or simply HID lamps. The light output and color rendition of HID lamps vary considerably depending on the lamp family (mercury, metal halide or sodium lamps). HID lamps can only be started and operated with ballasts. Ignitors or ignition voltage characteristics are additionally required for sodium and metal halide lamps. As well as stabilizing the lamp’s operating point, ballasts also influence the lamp’s output and luminous flux, the system light output, the service life of the lamps as well as the color temperature of the light source. Electromagnetic or electronic ballasts can be used for HID lamps, but unlike fluorescent lamps, lamp efficiency is not significantly improved by the use of electronic ballasts. However, electronic ballasts can lead to a reduction of the inherent losses and thus to an increase in system efficiency. In addition, electronic ballasts can ensure gentle lamp operation, which may increase lamp’s service life. Electronic Ballasts for Metal Halide Lamps Electronic ballasts are designed with all the components required to operate metal halide lamps, including ignition, power factor correction, and stable normal operation. Furthermore, they safely shutdown lamps at the end of their service life to prevent high temperatures from being generated in the luminaires that could influence the service life of the luminaire or its components. Vossloh-Schwabe also provides special electronic ballasts for additional luminaire functions such as heater power for insulation detection thermal protectors and for switching on of an auxiliary incandescent lamp for the dark phase of an HID lamp during initial warm-up or during hot-restrike cool-down mode. Standards/Regulations ANSI C82.14 Low-Frequency Square Wave Electronic Ballasts for Metal Halide Lamps UL 1598 Standard for Safety-Luminaires ANSI C82.77 Harmonic Emission Limits-Related Power Quality Requirements or Lighting Equipment ANSI/UL 1029 Standard for Safety-High Intensity HID Lamp Ballasts ANSI/IEEE C62.41 Surge Voltages in Low Voltage AC Power Circuits ELECTRONIC HID US Code of Federal Regulations Title 47 –Telecommunications Part 18– Industrial, Scientific and Medical Devices PAGE 6-7 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Application And Operating Information Technical Specifications: Operating voltage range 120VAC rated: 120V 277V ±10% 277VAC rated: 277V ±10% 120–277V rated: 108V–305V 120/277V rated: 108V–132V and 249V–305V Leakage current ≤0.5mA Hot restrike auxiliary lamp operation In order to ensure continuous illumination even during the ignition period or in the event of a lamp drop-out due to short term power outage, an additional incandescent lamp (maximum 150W) can be used on models designated with a JA suffix. Short circuit issues The ballast output metal halide lamp leads are basically short-circuit-proof. However, any shorts or connections between those lamp leads to the ballast case or to safetyneutral (earth ground) will destroy the ballasts. Likewise the metal halide lamp leads shall not be connected to input power connections nor shall the auxiliary lamp leadsbe shorted together otherwise the ballast’s circuitry could be damaged or fail. Provisions in the luminaire design should be implemented to prevent all lead wires but especially lamp leads from being pinched, damaged, or cut during luminaire assembly, field installation or normal service. Mechanical Mounting: Surface Firm, flat, preferably metal surface required to ensure good heat transfer for long ballast service life and reliability. Avoid mounting on uneven or protruding surfaces. Mounting Location Electronic ballasts must be protected against moisture and heat. Outdoor applications must utilize luminaires with the appropriate weatherproof ratings depending on location. Most Vossloh-Schwabe electronic ballasts are rated “Outdoor Type 1”. Fastening Use mechanical means to ensure ballasts are fixed tightly to flat surfaces. Use appropriately sized screws depending on the ballast mounting slot size or spring clips to provide interference fit. If ballast is destined for installation in a luminaire, sufficient heat transfer must be ensured between the electronic ballast and the luminaire housing. Electronic ballasts should be mounted with the greatest possible clearance from heat sources or lamps. During operation, the temperature measured at the ballast’s tc point must not exceed the specified maximum value. PAGE 6-8 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) ELECTRONIC HID Heat transfer Application And Operating Information Technical Specifications: • Dimensional tolerances: – Case: ±1mm (±0.039”) – Standard lead length tolerances: +50mm (+2”) or –30mm (–1”) Micro lead length tolerances: ±15mm (±0.6”) – Slot width on “F” mounting tabs: 5mm (0.20”); for Mini-Square Size: 4mm (0.157”) • Remote wiring guidelines: – Each lamp’s lead wires must be run in a separate conduit from the input power leads to achieve good EMI performance and maximum remote capabilities. Lamp leads shall not be bundled together, but each set of lamp leads shall be run in its own conduit. – Individual lamp lead wires must be used for external fixture wire extensions using wire types SF-2 (equivalent to SEW-2 or 3071) or SFF-2 (equivalent to SEWF-2 or 3070) or alternately, if approved by VS, high voltage luminaire wire with a 18AWG conductor and a 1000VAC minimum voltage rating. Temperature rating is especially critical if the lamp lead extension wires are directly connected to lampholder terminals. – Maximum remote distances: See individual model specification sheets. The specified maximum remote distances are based on lamp leads run in a minimum ½” internal diameter conduit, pipe or flexible conduit. For longer remote distances contact the TES group at Universal Lighting. – Using service power cords (types SJ, SO, ST, SV etc.) or metal clad cable assemblies for lamp lead extension wire are not recommended as they are not compatible with the above characteristics, can cause starting problems and shall not be used unless VS gives written approval. Insulation clearance ELECTRONIC HID Remote mounted ballasts shall be installed per National Electrical Code and local codes while also complying with wiring methods per Vossloh-Schwabe recommendations. Per UL requirements, thermal insulation shall be a minimum of 3” from any ballast surface. PAGE 6-9 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Application And Operating Information Safety Functions: Regulatory approvals Vossloh-Schwabe electronic HID ballasts are UL listed or UL recognized component and cUL listed for use in Canada. Shutdown of defective lamps In the event of a lamp failing to ignite or of a lamp with low or high operating voltages (end of lamp’s service life), the electronic ballast will switch off after a defined period of time (typically 30 minutes). The ballast will also shut-down if the lamp fails to achieve symmetrical current operation (rectification) or if lamp leads are shorted to each other. After lamp replacement, the ballast output can be reset by disconnecting (count to 10) and then reconnecting input power. Transient input voltage Electronic ballasts incorporate transient protection that complies with ANSI C62.41 and ANSI C82.14 test procedure and values. Temperature Protection To prevent excess temperatures, ballasts contain thermal protection devices or thermal sensing circuitry. A ballast will restart after it has cooled down, however, it might be necessary to briefly reset the input power after the over-temperature condition is resolved. General guidelines Always disconnect power to the luminaire before installation or service of the ballasts. Install to all provisions of local or National Electric Codes. The ballast case/green lead must be grounded. Dispose of any replaced ballasts or lamps properly per local environmental regulations. Reliability and Service Life: The electronic ballast service life is inversely proportional to the temperature of its critical internal components. Normal ballast operation shall have the temperature of the tc point less than the warranted values in the individual specification sheets Electrical Installation: 3-Phase connection of luminaires with electronic ballasts Power factor compensation Luminaires with electronic ballasts do not need power factor compensation, as the typical power factor range of electronic ballasts is 95 to 99%. PAGE 6-10 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) ELECTRONIC HID Prior to operating newly installed lighting systems, please check the ballast’s rated voltage range to ensure it is appropriate for the job site input power supply voltage. The neutral power supply wire must be connected securely to all luminaires and to all ballasts. Power supply conductors must only be connected or disconnected when the circuit is not energized. The neutral conductor must never be disconnected as the first disconnected wire nor individually at the circuit panel, at a distribution wiring junction box or at the luminaire during energized power supply operation as out-of balance voltage operation can lead to serious over-voltages and subsequent ballast failures. Application And Operating Information Wiring Wiring between the power supply, electronic ballasts and lamp must comply with the respective circuit diagram. Note: the ballast (metal) case (using toothed washer) or provided green lead must be connected to safety-neutral (earth ground). In addition, all metal luminaire parts and metal lamp reflector/housings shall also be connected to earth ground for safety and for proper lamp starting. Metal halide luminaires must only be fitted with electrical components that are rated to withstand ignition voltages of 4kV. To ensure compliance with RFI suppression limits, input and output conductors should not be run in the same conduit as lamp conductors. Conduit size recommendations are stated in the individual ballast specification sheets or construction notes. Lamp maintenance notice To replace end-of-service lamps, turn-off luminaire power, remove and replace lamps then turn-on luminaire power. If power was not turned off during lamp replacement, the luminaire/ballast-input power must be reset to restart the new lamp. If the lamp or wiring is defective, the ballast will “shut-down” in 1.5 to 30 minutes depending upon the fault condition. Supplemental IDTP wiring The IDTP (insulation detector thermal protector) is required by UL for most recessed luminaires. This fast acting thermal protector is typically mounted on the same junction box as the electronic ballast. Special “JT” electronic ballasts provide a separate 120V power supply for the IDTP heater to allow the luminaire to be rated for both 120V and 277V operation. See the individual ballast specifications for the proper wiring procedures for JT & JA ballasts with this IDTP heater function. Note: When using JT or JA ballasts on multiple lamp luminaires, only one ballast yellow or purple lead should be connected to the IDTP heater. All other ballasts’ yellow or purple leads should be capped-off. Operation of JT and JA ballasts on 208V and 240V is not recommended, as the IDTP may not function properly. Lamp compatibility ELECTRONIC HID Not all HID lamps are compatible with all electronic ballasts. Therefore, consult with Vossloh-Schwabe Technical Support or a specific lamp company regarding a certain lamp’s compatibility. PAGE 6-11 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Sign Illuminating Ballasts A Complete Range Of Solutions… From The Name You Trust Universal Lighting Technologies (“Universal”) is known throughout the sign business as a company that can set and meet today’s toughest industry standards. Our high-output ballasts are great for rugged outdoor sign cabinet applications because they provide ultra-reliable, low-temperature starting as low as -20° F. All Universal sign ballasts offer Class P thermal protection. We have three product lines spanning the sign business: • The UNIVERSAL® USB is a line that offers complete coverage with 6 units. • The UNIVERSAL® MAX-3 ensures that the installer has the right sign ballast on the truck for every application, from 1-6 lamps, 2-48 feet — replacing up to 100 conventional ballasts with a maximum of three models. • Signa® Electronic Sign ballasts are ideal for new sign installations with minimum wire connections, universal input voltage, parallel lamp operation, and maximum energy savings. Universal offers the convenience of one-stop shopping for not just sign ballasts, but compact fluorescent, linear fluorescent, HID, and all your other ballast needs. For the unmistakable sign of quality and reliability, turn to Universal. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group Plastic Sign Ballasts Universal ® sign ballasts provide ultra-reliable low-temperature starting — plus Class P thermal protection. Application And Operating Information Heat Ballasts generate heat during normal operation. By design, fluorescent ballasts should operate so that their maximum hot-spot case temperature does not exceed 90°C (194°F). Operating at higher temperatures will shorten ballast life or may cause the thermal protection cicuit to trip. The temperature the ballast reaches depends on the temperature of the area surrounding it — plus the heat-conducting surface touching the ballast. Ballasts should be installed in a manner that avoids future overheating. To maintain normal ballast temperature, you should: 1. Mount the ballast against a flat surface of heavy gauge metal such as the structural part of the sign. 2. K eep the ballast as far away as possible from other ballasts, lamps or reflective surfaces. (Lamps generate approximately three-fourths of the heat in a plastic sign.) The ends of the lamps are the hottest part, so you should mount the ballast as far away from the ends as possible. 3. Paint the inside of the sign with flat white paint. Moisture Protection 1. Vent the sign as well as possible without allowing water to enter. 2. B allasts should be mounted horizontally (except for weatherproof types). If the ballast must be mounted vertically, allow room for sufficient air circulation. Wherever possible, mount the ballast in an enclosure outside the sign by using Universal pup tents. You can get pup tents at no charge when you order the plastic sign ballast. Your wholesaler will also have a supply for your convenience. Grounding Plastic Sign Ballasts The white lead of a 120-volt ballast must be connected to the neutral or ground side of the power supply. All metal parts of the sign, as well as the ballast case, must be grounded either through the conduit which holds the power supply or by direct connection with a grounding wire. An ungrounded sign is a potential hazard—and it can give misleading symptoms when looking for sign faults. Proper Lamp Life and Starting In rapid-start installations, proper filament heating is necessary for reliable starting and normal lamp life. To ensure that proper heating is taking place, the following steps are recommended: 1. Lamp leads should be kept as short as possible and with a minimum of splices. 2. All connections should be soldered. 3. Maintain proper alignment and spacing of lamp holders to ensure good contact in the sockets. 4. Mount lamps within one inch of grounded metal. This is one lamp manufacturer’s published requirement for reliable starting. Light Output vs. Temperature The light output of a fluorescent lamp varies according to the mercury vapor pressure inside the lamp. This pressure is controlled by the coldest spot on the bulb wall. The ballast may start the lamp, but the light output can be very low if the bulb wall temperature is low. Several factors influence this, including ambient temperatures, wind, type of enclosure, etc. If maximum light output is critical, consult a lamp manufacturer for advice. Lamp Starting Problems Occasionally a field problem will arise involving improper lamp starting. The usual complaint is that the lamps start slowly (or not at all). Here are some of the causes: 1. Low line voltage 2. Improper sign grounding 3. Insufficient or no filament voltage 4. Insufficient or no open circuit voltage 5. Dirty lamps during high-humidity operating conditions 6. Lamps improperly inserted in the sockets If lamp starting is a problem in your installation, check the sign grounding, filament voltage (3.4 - 3.9 volts), and open circuit voltage. If all are normal, the probable cause is dirty lamps. The lamps should be washed in clean water, drip-dried, and reinstalled. If this doesn’t solve the problem, contact your nearest Universal representative for further assistance. Short Lamp Life If the lamp has not given proper length of service as specified by the lamp manufacturer, the following reasons for early failure should be considered: 1. Improper starting due to insufficient filament voltage 2. Frequent starting and short operating periods 3. Improper ballast 4. Improper voltage supply 5. Faulty wiring 6. Defective lamps 7. Lamps improperly inserted in sockets Early lamp failure will be preceded by a dense blackening on either or both ends of the lamps. This blackening will extend three or four inches from the lamp base and should not be confused with a small dense spot, which is a mercury deposit that can occur any time during lamp life. Dense blackening due to early lamp failure should not be confused with the gray bands that sometimes appear toward the end of normal lamp life (about two inches from either end of the lamp). PAGE 6-2 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Sign Ballast Footage Chart UNIVERSAL® USB Fluorescent Sign Ballast Matrix No. of Lamps Per Ballast 2 TOTAL LAMP FOOTAGE REQUIRED 4 1-2 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 USB-0412-12 1-4 USB-0816-14 USB-1024-14 2-4 USB-1632-24 4-6 USB-2036-46 USB-2048-46 UNIVERSAL MAX-3 Fluorescent Sign Ballast Matrix ® No. of Lamps Per Ballast 2 TOTAL LAMP FOOTAGE REQUIRED 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 32 34 36 38 40 42 44 46 48 USB-0218-16 1-6 USB-1232-16 USB-1048-16 SIGNA® Electronic Sign Ballast Matrix No. of Lamps Per Ballast 2 1-2 TOTAL LAMP FOOTAGE REQUIRED 4 6 8 10 12 14 16 18 20 22 24 26 28 30 ESB216-12 2-4 ESB432-14 4-6 ESB848-46 1-4 ESB1040-14 Plastic Sign Ballasts LEAD LENGTHS (Inches) Catalog Number White Black Blues Reds Yellows Browns Oranges Orange Blacks Blue Whites Red Whites Note: Maximum volts above ground, any lead 590 volts. PAGE 6-3 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Plastic Sign Ballasts PLASTIC SIGN BALLASTS - HIGH OUTPUT 800mA RS LAMPS - 120 Volts - 60 Hz WO LAMP BALLASTS T USB-0412-12 24 24 38 38 48 FOUR LAMP BALLASTS USB-0816-14 36 24 65 40 39 56 48 USB-1024-14 24 24 79 48 75 83 57 USB-1632-24 24 24 80 54 60 80 72 SIX LAMP BALLASTS USB-2036-46 24 24 50 80 70 38 50 50 38 USB-2048-46 24 24 80 80 70 50 50 50 50 MAX-3 HIGH OUTPUT SIGN BALLASTS 800mA RS LAMPS - 120 Volts - 60 Hz ONE TO SIX LAMP BALLASTS USB-0218-16 24 24 60 60 60 60 60 60 60 USB-1232-16 24 24 80 60 60 80 60 60 72 USB-1048-16 24 24 80 80 70 50 60 60 50 SIGNA ELECTRONIC SIGN BALLASTS- T12 RAPID START HIGH OUTPUT LAMPS - 108 to 305 VOLTS - 50/60 Hz ONE TO SIX LAMP BALLASTS ESB216-12 68 68 ESB432-14 80 80 80 80 ESB848-46 80 80 80 80 80 80 HIGH OUTPUT BALLASTS • Provide ultra-reliable low-temperature starting (as low as –20°F) STANDARD HIGH OUTPUT SIGN BALLASTS • Support 1 to 6 lamps • Ideal for rugged outdoor sign cabinet applications • Class P thermally protected Total Lamp Footage Catalog Number Start Temp (°F) Max. Line Cur. Max. Input Watts Open Circuit Wiring Dimen. Volt. Diagram Chart Ref. PLASTIC SIGN BALLASTS - HIGH OUTPUT 800mA RS LAMPS - 120 Volts - 60 Hz TWO LAMP BALLASTS USB-0412-12 4´ min. - 12´ max. FOUR LAMP BALLASTS USB-0816-14 8´ min. - 16´ max. USB-1024-14 10´ min. - 24´ max. USB-1632-24 16´ min. - 32´ max. SIX LAMP BALLASTS USB-2036-46 USB-2048-46 LINE 20´ min. - 36´ max. 20´ min. - 48´ max. WHITE BLACK BLUE BLUE BALLAST Weight (lbs.) -20 1.35 160 500 1a, 2a 1 8 -20 -20 -20 1.90 2.70 3.50 220 325 420 590 720 950 4a, 6a, 9, 1b 4a, 6a, 9, 1b 4a, 6a, 9 2 3 4 12 14 16 -20 -20 4.00 5.00 480 600 600 720 5a, 7, 7a 5a, 7, 7a 4 4 18 18 BLACK BLUE BLUE BROWN BROWN YELLOW YELLOW LINE RED RED YELLOW YELLOW BALLAST LINE RED RED BLUE/WHITE BLUE/WHITE WHITE BLACK YELLOW YELLOW BALLAST RED RED BLUE BLUE LAMP 1 LINE LAMP 2 LAMP LAMP Diagram 1a Diagram 1b WHITE BLACK BROWN BROWN YELLOW YELLOW BALLAST LINE BLUE BLUE BLUE / WH BLUE / WH RED RED WHITE BLACK BROWN BROWN BLUE / WH BLUE / WH YELLOW YELLOW BALLAST MOUNT LAMPS WITHIN 1˝ OF GROUNDED METAL REFLECTOR Diagram 2a BLUE BLUE ORANGE / BLK ORANGE / BLK ORANGE ORANGE RED RED LINE LAMP 1 LAMP 1 BLACK WHITE YELLOW YELLOW BROWN BROWN BALLAST LAMP 2 LAMP 2 LAMP 1 LAMP 3 LAMP 2 LAMP 3 LAMP 4 LAMP 3 LAMP 5 LAMP 4 LAMP 6 MOUNT LAMPS WITHIN 1˝ OF GROUNDED METAL REFLECTOR INDIVIDUALLY CAP THE YELLOW LEADS MOUNT LAMPS WITHIN 1˝ OF GROUNDED METAL REFLECTOR Diagram 4a Diagram 6a Diagram 5a LINE BLACK WHITE BROWN BROWN BLUE / WH BLUE / WH YELLOW YELLOW BALLAST RED RED BLUE / WH BLUE / WH BLUE BLUE BLUE BLUE ORANGE / BLK ORANGE / BLK ORANGE ORANGE RED RED LAMP 1 LAMP 2 LAMP 3 3 LAMP 4 4 LAMP 5 INDIVIDUALLY CAP THE YELLOW LEADS Plastic Sign Ballasts Diagram 7 Diagram 9 Diagram 7a PLASTIC SIGN FLUORESCENT BALLASTS DIMENSION CHART - STANDARD CASE (INCHES) Ref. # 1 2 3 4 A B C D E 10 37/64˝ 1037/64˝ 13 3/16˝ 15 3/16˝ 1145/64˝ 1145/64˝ 14 5/16˝ 16 11/16˝ 119/64˝ 119/64˝ 13 3/4˝ 161/8˝ 13/4˝ 2 43/64˝ 2 43/64˝ 2 43/64˝ 3 3/16˝ 3 3/16˝ 3 3/16˝ 3 3/16˝ PAGE 6-4 Diagrams Notes: Note 1: When operating a two-lamp ballast on one lamp insulate each yellow lead. Note 3: When operating a four-lamp ballast on three lamps insulate each yellow blue/white, and brown lead. FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) UNIVERSAL® MAX-3 HIGH OUTPUT SIGN BALLASTS • Superior fill material coats all components and fills all voids to dissipate heat for cooler operation, longer life. • Supports 1 to 6 lamps, 2 to 48 feet total length • Low watt-loss steel lamination and all-copper coils assure cooler, more efficient operation and performance. • Class P thermally protected Total Lamp Footage Catalog Number Start Temp (°F) Max. Line Cur. Max. Input Watts Open Circuit Wiring Volt. Diagram MAX-3 HIGH OUTPUT SIGN BALLASTS 800mA RS LAMPS - 120 Volts - 60 Hz ONE TO SIX LAMP BALLASTS USB-0218-16 USB-1232-16 USB-1048-16 2´ min. - 18´ max. 12´ min. - 32´ max. 10´ min. - 48´ max. -20° -20° -20° 2.00 3.50 4.80 240 410 570 MAX-3 BALLASTS 625 970 800 3, 4, 5, 6, 7, 8 3, 4, 5, 6, 7, 8 1, 2, 3, 4, 7, 8 Dimen. Chart Ref. Weight (lbs.) 1 1 2 15 16 18 See page 6-3 for Lead Lengths 2 3 Diagram 1 Diagram 3 Diagram 2 2 Diagram 5 3 Diagram 6 4 5 Diagram 4 3 4 Diagram 7 Diagram 8 Ref. # 1 2 A B C D E 13 3/16˝ 159/16˝ 145/16˝ 1611/16˝ 13 3/4˝ 16 1/8˝ 2 43/64˝ 2 43/64˝ 3 3/16˝ 3 3/16˝ PAGE 6-5 Diagrams Notes: Note 1: When operating a two-lamp ballast on one lamp insulate each yellow lead. Note 2: When operating a three-lamp ballast on two lamps insulate each yellow and blue/white lead. Note 3: When operating a four-lamp ballast on three lamps insulate each yellow blue/white, and brown lead. FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) MAX-3 Series Ballasts MAX-3 SERIES HIGH OUTPUT SIGN BALLASTS DIMENSION CHART ELECTRONIC SIGN BALLASTS Catalog Number SIGNA® ELECTRONIC SIGN BALLASTS • Instant start for maximum energy savings • Simplified wiring for fewer connections • Universal input voltage • Parallel Lamp Operation Total Lamp Footage Start Temp Input (°F) Voltage Max. Input Watts Max. Line Wiring Current (A) Diagram Dimen. Chart Ref. Weight (lbs.) T12HO UP TO 8’ IN LENGTH OR T8HO UP TO 6’ IN LENGTH - 120 to 277 Volts - 50/60 Hz ONE TO TWO LAMP BALLASTS ESB216-12 2´ min. - 16´ max. -20 ONE, TWO, THREE OR FOUR LAMP BALLASTS 120 277 134 130 1.12 0.47 10 1 4.2 120 277 280 274 2.34 0.99 11 2 7.4 120 277 408 395 3.41 1.47 12 3 9.7 120 ESB1040-14 10´ min. - 40´ max. -20 277 Consult www.signasign.com for complete specification information 341 331 2.85 1.25 11 3 10 ESB432-14 4´ min. - 32´ max. -20 FOUR, FIVE OR SIX LAMP BALLASTS ESB848-46 8´ min. - 48´ max. -20 T12HO UP TO 8’ IN LENGTH OR T8HO UP TO 8’ IN LENGTH - 120 to 277 Volts - 50/60 Hz ONE, TWO, THREE OR FOUR LAMP BALLASTS Diagram 11 Electronic Sign Ballasts Diagram 10 Diagram 12 ELECTRONIC SIGN BALLASTS DIMENSION CHART - STANDARD CASE (INCHES) Ref. # 1 2 3 A B C D E 10 37/64 ˝ 133/16˝ 15 9/16˝ 1145/64˝ 14 5/16˝ 16 11/16˝ 119/64˝ 13 3/4˝ 161/8˝ 13/4˝ 2 43/64˝ 2 43/64˝ 3 3/16˝ 3 3/16˝ 3 3/16˝ PAGE 6-6 Diagrams Notes: When Operating less than the maximum number of lamps, insulate unused blue leads. FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) Glossary Class P Thermal Protector–A switching device sensitive to current and heat that automatically disconnects ballast if the ballast temperature exceeds UL temperature limitations. Coil–Windings of copper or aluminum wire surrounding the steel core in ballast. Core–Component of electromagnetic ballast that is surrounded by the coil. Core is comprised of steel laminations or solid ferrite material. Core & Coil Ballast–Another term for an electromagnetic ballast. Crest Factor (Lamp Current Crest Factor)–Ratio of peak lamp current to RMS or average lamp operating current. Efficacy–Lumen output per unit of power supplied to ballast (lumens per watt). Electrical Testing Laboratory (ETL)–Independent testing laboratory that performs ballast tests and certifies accuracy of performance data. Electrode–Metal filaments that emit electrons in a fluorescent lamp. Negatively charged free electrons emitted by one electrode are attracted to the positive electrode (anode), creating an electric current and arc between electrodes. Electromagnetic Ballast (Magnetic Ballast)–A ballast that uses a “Core & Coil” assembly to transform electrical current to start and operate fluorescent lamps. EMI (Electromagnetic Interference)–Electrical interference (noise) generated by electrical and electronic devices. Levels generated by high frequency electronic devices are subject to regulation by Federal Communications Commission (FCC). Filament–Metal Tungsten wire coated with Barium Oxide that emits electrons when voltage is applied. Filament Voltage–Voltage applied to the lamp cathode. Fluorescent Lamp–Gas filled lamp in which light is produced by the interaction of electrons with phosphors lining the lamp’s glass tube. Foot Candles–Measure of light level on a surface being illuminated. Defined as one lumen of light per one square foot of surface area. Four-Pin Compact Fluorescent Lamps–Type of lamps that do not have any starter built into the base of the lamp. Therefore, the ballast has the starting circuit. Traditionally 4-pin lamps are designed to work with electronic ballasts; however, Universal does offer magnetic ballasts to operate some 4-pin lamps. Frequency–Rate of alteration in an AC current. Expressed in cycles per second or Hertz (Hz). Harmonic–An integral multiple of the fundamental frequency (60 Hz) that becomes a component of the current (see “Harmonic Distortion”). Harmonic Distortion–Distortion of an AC waveform caused by multiples of the fundamental frequency (harmonics). Odd triplet harmonics (thirds, ninths, etc.) may result in large currents on the neutral line in a four-wire Wye three-phase system. Hertz (Hz)–Unit used to measure frequency of alteration of current or voltage; cycles per second. FOR MORE INFORMATION CALL PAGE 7-1 1-800-BALLAST (225-5278) Glossary AC (Alternating Current)–Current which passes from the generator in one direction and then the other, alternately ANSI (American National Standards Institute)–Non-profit organization that generates voluntary product performance standards for many U.S. industries. ANSI Standard C82.1 applies to electromagnetic ballasts. Arc–Intense luminous discharge formed by the passage of electric current across a space between electrodes. Auto Reset Shutdown Circuit–Circuit senses lamp end of life and will automatically shut off power to the lamp(s). When a new lamp is inserted in the socket, the ballast resets, and turns on the lamp automatically. Some shutdown circuits require the power to be interrupted before a new lamp will re-light. Ballast–Device for starting and regulating fluorescent and high intensity discharge lamps. Ballast Efficacy Factor (BEF) – Value used to evaluate various lighting systems based on light output and power input. The BEF can only be used to compare systems operating the same type and quantity of lamps. Ballast Factor (BF)–Measure of light output from lamp operated by commercial ballast as compared to a laboratory standard reference ballast. Ballast factor .94 means ballast produces 94% of light produced by ANSI C82.2 reference ballast operating same lamps. Ballast Hum–Sound generated by the vibration of laminations in the electromagnetic field that transforms the current for discharge lamp use. Ballast Losses–Power which is supplied to a ballast that is not converted into lamp energy. Ballast loss is dissipated as heat. Bottom Exit (BE)–A configuration with leads or a wire-trap on the bottom or base of the ballast. This type of configuration is usually used when the ballast is mounted onto a junction box plate. Bottom Exit Studs (BES)–A configuration with screw studs mounted on the base plate or bottom of the ballast. The screws are 3/8˝ inches long with a #8-32 thread size (#8-32 nut). They are mounted on a two-inch center. The studs are usually used to mount the ballast directly onto a junction box plate. Canadian Energy Standards – Indicates ballast complies with Canadian Energy Standards and meets the requirements ofCAN/CSA-C654-M91. Canadian Standards Association (CSA)–Association that generates product performance and safety standards for many Canadian industries. Capacitor–Device in ballast that stores electrical energy. Often used for power factor correction and lamp regulation(see “Power Factor”). Cathode–See “Electrode”. Centigrade (C)–Celsius temperature scale where 0°C = 32°F. Circle E–Designates a ballast meets or exceeds the requirements of Public Law 100-357 establishing standards of efficiency. Glossary Glossary High Efficiency (Energy Saving) Electromagnetic Ballast– Ballast with Core & Coils, designed to minimize ballast losses compared to the “standard” ballast. High Intensity Discharge (HID) Lamp–A lamp containing a filled arc tube in which the active element becomes vaporized (a gaseous state) and is discharged into the arc stream to produce light. High Power Factor–A ballast whose power factor is corrected to 90% or greater by use of a capacitor. Incandescent Lamp–Lamp in which light is produced by a filament heated by an electric current. Input Voltage–Power supply voltage required for proper operation of an arc discharge lighting ballast. Inputs Watts–The total power input to the ballast which includes lamp watts and ballast losses. The total power input to the fixture is the input watts to the ballast or ballasts and is the value to be used when calculating cost of energy and air conditioning loads. Instant Start Lamp–a fluorescent lamp with a single pin at each end. The lamp is ignited by a high voltage without any filament heating. Instant Start–Lamp starting method in which lamps are started by high voltage input with no preheating of lamp filaments. Some rapid start lamps are designed so that they may be instant started. Laminations–Layers of steel, making up the “core” that is surrounded by the coils in a core & coil ballasts. Lamp Current Crest Factor–See “Crest Factor”. Lamp Filament–See “Electrode”. Lamp Watts –Input power used to operate lamps. Lumens/Watt–A measurement of white light produced by each output watt. Metal Cases–Case design used in both magnetic and electronic ballasts. These ballasts are grounded once they are mounted to the fixture. They meet all safety codes, some of which do not allow plastic in open plenum areas. National Electric Code (NEC)–A nationally accepted electrical installation code to reduce the risk of fire, developed by the National Fire Protection Association. National Energy Standards for Fluorescent Ballasts–A federal law enacted in 1988 that sets energy standards for ballasts consistent throughout the United States. NOM –Laboratory that sets safety standards for building materials, electrical appliances and other products for Mexico. Non-PCB Capacitor–Capacitor used in ballasts to help provide power factor correction. Contains no polychlorinated biphenyls and meets EPA requirements. Normal Power Factor–Ballasts with power factor less than .90 and do not incorporate any means of Power Factor Correction. Parallel Lamp Operation–Refers to ballasts that employ multiple-output current paths from a single ballast to allow lamps to operate independent of one another, allowing other lamps operated by the ballast to remain lit should companion lamp(s) fail. PCB (Polychlorinated Biphenyls)–Chemical pollutant formerly used in ballast capacitors. Potting–Material used to completely surround and cover components of some magnetic and electronic ballasts. Potting compound fulfills functions of protecting components, dampening sound, and dissipating heat. Power Factor–Measurement of the relationship between the AC source voltage and current. High power factor ballasts require less AC operating current operating at the same wattage than an equivalent low power factor ballast. Formula: Power Factor equals Input Watts divided by the product of Line Volts times Line Amps (Volt Amps or VA). Power Factor Corrected–Ballasts that incorporate a means of Power Factor Correction but whose power factor is <90% and >50%. Preheat Lamp–A fluorescent lamp in which the filament must be heated by use of a starter before the arc is created. These lamps are typically operated with electromagnetic ballasts. Programmed Rapid Start–lamp starting method which preheats the lamp filaments while not allowing the lamp to ignite and then applies the open circuit voltage (OCV) to start the lamp. The user may experience a half to one-second delay after turning on the lamps while the pre-heating takes place. This type of starting circuit keeps lamp end blackening to a minimum and improves lamp life performance, especially in applications where the lamps are frequently switched on and off. Rapid Start Lamp–A fluorescent lamp with two pins at each end connected to the filament. The filaments are heated by the ballast to aid in starting. Some rapid start lamps may be instant started without filament heat, for example, the F32T8 lamp. Rapid Start–Lamp starting method in which lamp filaments are heated while open circuit voltage (OCV) is applied to facilitate lamp ignition. Series Lamp Operation–Refers to ballasts that employ a single current path passing through all lamps operated by the ballast. If one lamp should fail, companion lamps operated by the same ballasts will also extinguish or dim. Standard Alternating Current Frequency in the United States– 60 Hertz (Hz) or 60 cycles per second. Total Harmonic Distortion (THD)–The combined effect of Harmonic Distortion on the AC waveform produced by a ballast or other device. Expressed as a percentage. Excessive levels of THD can create large currents on the neutral line of a four-wire Wye three phase system. (See “Harmonic Distortion”.) Transients–High voltage surges through an electrical system caused by lightning strikes to nearby transformers, overhead lines or the ground. May also be caused by switching of motors and compressors, as well as by short circuits or utility system switching. Can lead to premature ballast failure. Two-Pin Compact Fluorescent Lamps–Type of lamps that have the glow bottle starter built into the base of the lamp. Traditionally 2-pin lamps are designed to work with electromagnetic ballasts. UL (Underwriters’ Laboratories, Inc.)–Laboratory that sets safety standards for building materials, electrical appliances and other products. Watts–Measurement of electrical ability to do work. FOR MORE INFORMATION CALL PAGE 7-2 1-800-BALLAST (225-5278) Index Page # 200-C-S-P 200-H2 202-B-TC-P 202-SB-TC-P 213-TC-P 300-H2 412-L-SLH-TC-P 412-L-TC-P 413-C-TC-P 420-L-TC-P 443-L-SLH-TC-P 445-RS-WS-TC-P 446-L-SLH-TC-P 446-LR-TC-P 447-LR-TC-P 447-LR-VLH-TC-P 458-L-SLH-TC-P 480-SLH-TC-P 480-XLH-TC-P 481-LH-TC-P 487-SLH-TC-P 487-XLH-TC-P 490-XLH-TC-P 493B2 532-BR-TC-P 540-L-TC-P 546-B-TC-P 547-RS-WS-TC-P 554-L-TC-P 564-L-TC-P 567-L-TC 573-L-TC-P 595-L-TC-P 597-L-TC-P 631-LH-TC-P 698-L-SLH-TC 726-L-VLH-WS-TC-P 778-XLH-TC 806-BR-TC-P 806-SLH-TC-P 808-BR-TC-P 822-BR-TC-P 827-SLH-TC-P 828-BR-TC-P 831-TC 897-SLH-TC 930-K-TC-P 931-LH-TC-P 937-K-TC-P 1010-236RC-TC 1010-238C-TC 1010-239RC-TC 1010-245C-TC 1-24, 1-25, 1-26, 1-27 1-25, 1-26, 1-27 1-24, 1-27 1-24, 1-27 1-22 1-27 1-13, 1-14 1-30 1-13, 1-14 1-13, 1-14 1-13, 1-14 1-24 1-13, 1-14 1-30 1-26, 1-27 1-25, 1-26, 1-27 1-13, 1-14 1-17 1-17 1-16, 1-17 1-17 1-17 1-15, 1-16, 1-17 2-41 1-22 1-30 1-25, 1-26, 1-27 1-24 1-25, 1-26, 1-27 1-25, 1-26, 1-27 1-34 1-13 1-30 1-34 1-15, 1-16 1-13, 1-14 1-24 1-15, 1-16, 1-17 1-33 1-22, 1-23 1-33 1-22, 1-23 1-22, 1-23 1-22, 1-23 1-33 1-22, 1-23 1-19, 1-20 1-19, 1-20 1-19, 1-20 5-39 5-39 5-39 5-39 Catalog # 1010-246C-TC 1010-247SC-TC 1033-15S 1033-16S 1033-17S 1033-23S 1033-24S 1038-113S 1038-122S 1038-130S 1110-245SC-TC 1110-246C-TC 1110-247SC-TC 1110-564C-TC 1110-566C-TC 1110-568C-TC 1111-246C-TC 1111-247SC-TC 1120-251A-TC 11210-236C-TC 11210-239C-TC 11210-242C-TC 11210-277C-TC 11210-506C-TC 11210-539C-TC 11210-554C-TC 11210-606C-TC 1220-246C-TC 1233-10W 1233-24S 1233-35UN 1233-35W 1233-142W 1233-154W 1233-183S 1233-251UN 1233-251W 1238-133S 1238-183S 12210-236C-TC 12210-237C-TC 12210-239C-TC 12210-241C-TC 12210-261C-TC 12210-552C-TC 12210-602C-TC 12210-606C-TC 4105F2P 4105P 4112PBES 4113P 4114P 4114PBES Page # 5-39 5-39 5-43 5-34 5-34 5-43 5-34 5-33 5-36 5-36 5-38 5-38 5-52 5-38 5-38 5-38 5-38 5-38 5-38 5-38 5-38 5-38 5-38 5-38 5-38 5-38 5-38 5-39 5-26 5-27 5-26 5-26 5-26 5-27 5-27 5-26 5-26 5-36 5-36 5-39 5-39 5-39 5-39 5-39 5-39 5-39 5-39 1-25, 4-8 1-25 4-9 4-9 4-9 4-9 Index Index Catalog # FOR MORE INFORMATION CALL PAGE 9-1 1-800-BALLAST (225-5278) Index Index Catalog # Page # Catalog # Page # 4122PBES 4124PBES 4128PBES 4139F2P 4205F2P 4214PBES 4226PBES B114PUNVDV1 B128PUNVDV1 B132I120RH-A B132I277RH-A B132I347HP B132I347RH B132IUNVEL-A B132IUNVHE-A B132IUNVHP-B B132PUNVDV1 B132PUNVHP-A B132R120S30 B132R120S50 B132R120V5 B132R277S30 B132R277S50 B132R277V5 B132R347V5 B134R120M-A B140R120HP B140R277HP B154PUNVDV1 B159I120RH B159I277RH B214PUNVDV1 B224PUNV-C B228PU90S50D B228PU95S50D B228PU115S50D B228PUNV90-C B228PUNV95-D B228PUNV115-D B228PUNVDV1 B228PUNV-C B232I120EL B232I120HE B232I120L-A B232I120RES-A B232I120RES-G B232I120RH-A B232I120RHH-A B232I277EL B232I277HE B232I277L-A B232I277RH-A 4-10 4-11, 4-15 4-11, 4-15 4-19 4-8 4-9 4-11, 4-15 3-10 3-10 2-14, 2-16, 2-19, 2-30 2-14, 2-16, 2-19, 2-24, 2-26, 2-27, 2-30 2-14, 2-16, 2-19 2-14, 2-16, 2-19 2-14, 2-16, 2-19, 2-24, 2-27, 2-30 2-14, 2-16, 2-19, 2-24, 2-26, 2-27, 2-30 2-14, 2-16, 2-19, 2-24, 2-26, 2-27, 2-30 3-10 2-14, 2-16, 2-19, 2-24, 2-26, 2-29 3-13 3-13 3-12 3-13 3-13 3-12 3-12 2-38 2-37, 2-38 2-37, 2-38 3-10 2-32 2-32 3-10 2-35, 4-18, 4-19 3-15 3-15 3-15 2-34 2-34, 2-36 2-34, 2-36 3-10 2-34 2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27 2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27 2-14, 2-16, 2-19, 2-20, 2-30 2-14, 2-16, 2-19, 2-20 2-14, 2-16, 2-19, 2-20 2-14, 2-16, 2-19, 2-20, 2-24, 2-27, 2-30 2-20, 2-24 2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27 2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27 2-14, 2-16, 2-19, 2-20, 2-24, 2-27, 2-30 2-14, 2-16, 2-19, 2-20, 2-24, 2-27, 2-30 B232I277RHH-A B232I347HP-A B232I347HPL B232I347L-A B232I347RH-A B232IUNV-C B232IUNVEL-A B232IUNVHE-A B232IUNVHEH-A B232IUNVHP-B B232PUNVDV1 B232PUNVEL-A B232PUNVHE-A B232PUNVHP-A B232SR120S30 B232SR120V5 B232SR277S30 B232SR277V5 B232SR347V5 B234SR120M-A B234SR277M-A B239PUNV-D B240R120HP B240R120RH B240R277HP B254P347-D B254HRVHB-E B254PUNVDV1 B254PUNV-D B254PUNVHB-D B259I120HE B259I120HPL B259I120RH B259I120RHH B259I277HE B259I277HPL B259I277RH B259I277RHH B259I347HP B259IUNVHP-A B260I120M-A B260I120RH B260IUNVHP B286I120RH B286I277RH B295SR120HP B295SRUNVHP B332I120EL B332I120HE 2-20, 2-24 2-14, 2-16, 2-19, 2-20, 2-24, 2-27, 2-30 2-14, 2-16, 2-19, 2-20, 2-30 2-14, 2-16, 2-19, 2-20, 2-24, 2-27, 2-30 2-14, 2-16, 2-19, 2-20, 2-24, 2-27, 2-30 2-14, 2-16, 2-19, 2-20, 2-30 2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27 2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27 2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27 2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27, 2-30 3-10 2-20 2-20 2-14, 2-16, 2-19, 2-20, 2-24, 2-26, 2-27 3-13 3-12 3-13 3-12 3-12 2-37, 2-38 2-37, 2-38 2-35, 4-19 2-37, 2-38 2-37, 2-38 2-37, 2-38 2-35, 4-20 2-35, 4-20 3-10 2-35, 4-17, 4-19, 4-20 2-35, 4-17, 4-19, 4-20 2-32 2-32 2-32 2-32 2-32 2-32 2-32 2-32 2-30, 2-32 2-32 2-39, 2-40 2-39, 2-40 2-39, 2-40 2-33 2-33 2-41, 4-32 2-41 2-15, 2-17, 2-20, 2-21, 2-24, 2-25, 2-26, 2-27, 2-28 2-15, 2-17, 2-20, 2-21, 2-24, 2-25, 2-26, 2-27, 2-28 FOR MORE INFORMATION CALL PAGE 9-2 1-800-BALLAST (225-5278) Index Page # Catalog # Page # B332I120L-A B332I120RH-A B332I120RHH B332I277EL B332I277HE B332I277L-A B332I277RH-A B332I277RHH B332I347HP B332I347HPL B332I347RH B332I347L B332IHRVH-E B332IUNVEL-A B332IUNVHE-A B332IUNVHEH-A B332IUNVHP-A B332PUNVHP-A B332SR120S30 B332SR120V5 B332SR277S30 B332SR277V5 B340R120HP B340R277HP B432I120EL B432I120HE B432I120L-A B432I120RES-A B432I120RH-A B432I277EL B432I277HE B432I277HEH B432I277L-A B432I277RH-A B432I347HP B432I347HPL B432I347L B432I347RH B432IUNV-D B432IUNVEL-A B432IUNVHE-A B432IUNVHP-A 2-15, 2-17, 2-20, 2-21, 2-30 2-15, 2-17, 2-20, 2-21, 2-24, 2-25, 2-27, 2-28, 2-30 2-21 2-15, 2-17, 2-20, 2-21, 2-24, 2-25, 2-26, 2-27, 2-28 2-15, 2-17, 2-20, 2-21, 2-24, 2-25, 2-26, 2-27, 2-28 2-15, 2-17, 2-20, 2-21, 2-30 2-15, 2-17, 2-20, 2-21, 2-24, 2-25, 2-27, 2-28, 2-30 2-21 2-15, 2-17, 2-20, 2-21 2-15, 2-17, 2-20, 2-21, 2-30 2-15, 2-17, 2-20, 2-21 2-15, 2-17, 2-20, 2-21, 2-30 2-20, 2-21, 2-24, 2-25, 2-26, 2-28 2-15, 2-17, 2-20, 2-21, 2-24, 2-25, 2-26, 2-27, 2-28, 2-30 2-15, 2-17, 2-20, 2-21, 2-24, 2-25, 2-26, 2-27, 2-28, 2-30 2-15, 2-17, 2-20, 2-21, 2-24, 2-25, 2-26, 2-27, 2-28, 2-30 2-15, 2-17, 2-20, 2-21, 2-24, 2-25, 2-26, 2-27, 2-28 2-15, 2-17, 2-20, 2-21, 2-24, 2-25, 2-26, 2-27, 2-28 3-13 3-12 3-13 3-12 2-37, 2-38 2-37, 2-38 2-15, 2-17, 2-21, 2-22, 2-25, 2-26, 2-27 2-15, 2-17, 2-21, 2-22, 2-25, 2-26, 2-27 2-15, 2-17, 2-21, 2-22, 2-25, 2-30 2-15, 2-17, 2-21, 2-22 2-15, 2-17, 2-21, 2-22, 2-25, 2-30 2-15, 2-17, 2-21, 2-22, 2-25, 2-26, 2-28 2-15, 2-17, 2-21, 2-22, 2-25, 2-26, 2-28 2-15, 2-17, 2-21, 2-22, 2-25, 2-28 2-15, 2-17, 2-21, 2-22 2-15, 2-17, 2-21, 2-22, 2-30 2-15, 2-17, 2-21, 2-22 2-15, 2-17, 2-21, 2-22, 2-30 2-15, 2-17, 2-21, 2-22, 2-30 2-15, 2-17, 2-21, 2-22 2-15, 2-17, 2-21, 2-22, 2-30 2-15, 2-17, 2-21, 2-22, 2-25, 2-28, 2-30 2-15, 2-17, 2-21, 2-22, 2-25, 2-26, 2-28, 2-30 2-15, 2-17, 2-21, 2-22, 2-25, B432PUNVHP-A B432P277V5-E B432P277V5H-E B432SR277V5 B454PUNV-E B454PUNVHB-E C118PUNVDV3 C126PUNVDV3 C132PUNVDV3 C140PUNVDV3 C142PUNVDV3 C213/347 C213UNV C218/347 C218PUNVDV3 C218UNV C226PUNVDV3 C232PUNVDV3 C240PUNVDV3 C240PUNVHP-B C240SI120RH C240SI277RH C242/347 C242PUNVDV3 C242UNV C340SI120RH C340SI277RH C2642/347 C2642UNV CBT113L-120 CBT213L-120 CBT218L-120xC CBT126L-120 CF1320H2P CT213UNV CT218UNVSE ESB213-12 ESB432-14 ES1329A ES1510A ES1608A ES1679A ES1720B ES1786X ES4515K ES4528X ES4800A ES5000GT/HT ES5001GT/HT ES5002GT/HT ES5003GT/HT 2-26, 2-28, 2-30 2-15, 2-17, 2-21, 2-22, 2-25, 2-26, 2-28 3-12 3-12 3-12 2-35, 4-20 2-35, 4-20 3-10 3-10 3-10 3-10 3-10 4-9, 4-14 4-9, 4-14 4-10, 4-14 3-10 4-10, 4-14 3-10 3-10 3-10 4-19 4-19 4-19 4-11, 4-12, 4-15, 4-17, 4-18, 4-19, 4-20 3-10 4-11, 4-12, 4-15, 4-17, 4-18, 4-19, 4-20 4-19 4-19 4-11, 4-12, 4-15, 4-17, 4-18 4-11, 4-12, 4-15, 4-17, 4-20 2-34, 4-8, 4-9 2-34, 4-8, 4-9 4-10 2-34, 4-11, 4-17, 4-18 1-26, 1-27, 4-9 4-9 4-10, 4-18 7-6 7-6 2-14, 2-16, 2-20 2-14, 2-16, 2-19 2-14, 2-16, 2-19, 2-20 2-30 2-15, 2-17, 2-21, 2-22 2-42 2-35, 4-20 2-34 2-14, 2-16, 2-19, 2-20, 2-30 3-8 3-8 3-8 3-8 FOR MORE INFORMATION CALL PAGE 9-3 1-800-BALLAST (225-5278) Index Catalog # Index Index Catalog # Page # Catalog # Page # ES5006BM ES5007BMT ES5008BM ES5009BMT ES5010GT/HT ES5011GT/HT ES5012GT/HT ES5013GT/HT ES5702CTL ES5703CTL ES5704CTL ES5705CTL ES5720CTL ES5721CTL ES5722CTL ES5723CTL ES5723HT ES5733HT ES5734HT ES5817K ES5818K ES5821B ES5822B ES5825K ES5826K ES5827B ES5828K ES5829K ES5830K ES5831B ES5832B ES5833B ES5834B ES5835K ES5836K ES5838K ES5839K ES5840K ES5842K ES5843K ES5844K ES5846K ES5847K ES5848K ES5849K ES5850K ES5851K ES5852K ES5853K ES5860K ES5861K 3-11 3-11 3-8 3-8 3-11 3-11 3-11 3-11 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-11 3-11 3-11 3-11 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-11 3-11 3-11 3-11 3-8 3-11 3-8 3-8 3-8 3-11 3-11 3-11 3-8 3-11 3-8 3-11 3-8 3-11 3-8 3-11 ES5901CTL ES5902CTL ES5903CTL ES5961CTL HPS 150-3A HPS 150-4A HPS 150-5B HPS 150-45B HPS 150-G01 HPS 400-3A HPS 400-4A HPS 400-45B HPS 400-G05 HPS 450-1B HPS 460-1B HPS 600-1B HPS 1000-4B HPS 1000-55B M35MLTLC3M M35TRILC3M M50MLTLC3M M50TRILC3M M70MLTLC3D M70MLTLC3M M70TRILC3M M100MLTLC3D M100MLTLC3M M100TRILC3M M150MLTLC3D M150MLTLC3M M150TRILC3M M175ML5AC3M M175MLTAC3M M175MLTAE3M M175TRIAC30 M232SR120C M232SR277C M250ML5AC3M M250ML5AC4M M250MLTAC3M M250MLTAC4M M250MLTAE3M M250TRIAC3M M250TRIAC4M M260I120L M400ML5AC4M M400MLTAC4L M400MLTAC4M M400MLTAE4M M400MLTAI4X M400TRIAC4M 3-9 3-9 3-9 3-9 5-41 5-41 5-41 5-41 5-43 5-43 5-43 5-43 5-43 5-43 5-43 5-43 5-43 5-43 5-17 5-17 5-17 5-17 5-17 5-17 5-17 5-19 5-17 5-17 5-18 5-18 5-18 5-18 5-18 5-41 5-18 1-12 1-12 5-18 5-19 5-18 5-19 5-41 5-18 5-19 1-39, 1-40 5-19 5-19 5-19 5-41 5-42 5-19 FOR MORE INFORMATION CALL PAGE 9-4 1-800-BALLAST (225-5278) Index Page # Catalog # Page # M1000ML5AC5M M1000MLTAC5M M1000TRIAC5M M1500MLTAC5M M1500TRIAC5M M7048TLC3M M10048TLC3M M15048TLC3M M17548TAC3M M25048TAC3M M25048TAC4M M400120AC4M M400208AC4M M400277AC4M M40027TAC4M M40048TAC4M M100048TAC5M M150048TAC5M M100120LC3N M175120AC3M M175277AC3M M250120AC3M M250208AC3M M250230AC3M M250240AC3M M250277AC3M M250347AC3M M400230AC4M M1000120AC5M M1000208AC5M M1000230AC5M M1000240AC5M M1000277AC5M M1000480AC5M M1500230AC5M M1500480AC5M MH 70-3B MH 100-3A MH 100-5A MH 100-35B MH 150-35B MH 200-1B MH 350-1A MH150-G15 P 350-15B P175ML5AC3M P175MLTAC3M P175TRIAC3M P200ML5AC3M P200MLTAC3M P200TRIAC3M P250ML5AC4M 5-20 5-20 5-20 5-20 5-20 5-17 5-17 5-18 5-18 5-18 5-19 5-19 5-19 5-19 5-19 5-19 5-20 5-20 5-17 5-18 5-18 5-18 5-18 5-36 5-18 5-18 5-18 5-36 5-20 5-20 5-36 5-20 5-20 5-20 5-20, 5-36 5-20 5-43 5-43 5-43 5-43 5-43 5-43 5-43 5-43 5-43 5-22 5-22 5-22 5-22 5-22 5-22 5-22 P250MLTAC4M P250TRIAC4M P320ML5AC4M P320MLTAC4M P320TRIAC4M P350ML5AC4M P350MLTAC4M P350TRIAC4M P400ML5AC4M P400MLTAC4M P400TRIAC4M P450ML5AC4M P450MLTAC4M P750ML5AC5M P750MLTAC5M P750TRIAC5M P1000ML5AC5M P1000MLTAC5M P17548TAC3M P20048TAC3M P25048TAC4M P32048TAC4M P35048TAC4M P40048TAC4M P45048TAC4M P75048TAC5M P100048TAC5M P175277RCEM P200277RCEM P250277RCEM P32027TAFXM P320277RCEM P350277RCEM P350480AC4M P400277RCEM S35120RCEM S70120RCEM S50120RCEM S50MLTLC3M S70MLTLC3M S70TRILC3M S100120RCEM S100MLTLC3M S100TRILC3M S150120RCEM S150MLTLC3M S150TRILC3M S20048TAC4M S200MLTAC4M S200TRIAC4M S250240AC4M S250480AC4M 5-22 5-22 5-23 5-23 5-23 5-23 5-23 5-23 5-24 5-24 5-24 5-24 5-24 5-24 5-24 5-24 5-24 5-24 5-22 5-22 5-22 5-23 5-23 5-24 5-24 5-24 5-24 5-22 5-22 5-22 5-38 5-23 5-23 5-23 5-24 5-26 5-26 5-26 5-26 5-26 5-26 5-26 5-26 5-26 5-27 5-27 5-27 5-27 5-27 5-27 5-27 5-27 Index Catalog # FOR MORE INFORMATION CALL PAGE 9-5 1-800-BALLAST (225-5278) Index Index Catalog # Page # S250ML5AC4M S250MLTAC4M S250TRIAC4M S40048TAC4M S400ML5AC4M S400ML5AC5M S400MLTAC4M S400MLTAC5M S400TRIAC4M S400TRIAC5M S430MLTAC4M S600MLTAC5M S100024TAC5M S1000480AC5M S1000ML5AC5M S1000MLTAC5M S1000TRIAC5M S7027TLC3M S7048TLC3M S10027TLC3M S10048TLC3M S15027TLC3M S15048TLC3M S25048TAC4M S40048TAC5M S400230AC4M S400277AC4M S400480AC4M S100048TAC5M S150208LC3M S250230AC4M S400230AC4M S1000230AC5M SA-55 SA-100 USB-0218-16 USB-0412-12 USB-0816-14 USB-1024-14 USB-1048-16 USB-1232-16 USB-1632-24 USB-2036-46 USB-2048-46 W-589-D-TC-P 5-27 5-27 5-27 5-28 5-28 5-28 5-28 5-28 5-28 5-28 5-28 5-29 5-29 5-29 5-29 5-29 5-29 5-26 5-26 5-26 5-26 5-27 5-27 5-27 5-28 5-28 5-28 5-28 5-29 5-27 5-27, 5-36 5-36 5-36 5-43 5-43 7-3, 7-5 7-3, 7-4 7-3, 7-4 7-3, 7-4 7-3, 7-5 7-3, 7-5 7-3, 7-4 7-3, 7-4 7-3, 7-4 1-13, 1-14, 1-24 Catalog # Page # FOR MORE INFORMATION CALL PAGE 9-6 1-800-BALLAST (225-5278) Limited Warranty Universal Lighting Technologies, 26 Century Blvd., Suite 500, Nashville, TN 37214-3683, 1-800-BALLAST, (hereinafter called “Universal”) warrants to the purchaser that its lamp ballasts (hereinafter called “Lighting Products”) will be free from defects in material and workmanship for the specified warranty periods beginning from the date of manufacture. TRIAD Electronic Fluorescent Ballasts Universal, Energy Saving Electromagnetic Fluorescent Ballasts AddressPro, SuperDim, and DaliPro Ballasts Standard Universal Electromagnetic, Fluorescent & HID Ballasts Universal Sign Ballasts MAX-3 Series Sign Ballasts Basic-12 and Homestar Electronic Ballasts VS Lampholders VS Brand Magnetic IEC, Electronic IEC, Ignitors, Switches and Capacitors Electronic HID up to 60 Months* 36 Months 36 Months 24 Months 24 Months 36 Months 36 Months 36 Months 36 Months up to 60 Months* *Consult individual product information sheets at www.unvlt.com for specific warranty information. If it appears within the specified warranty period that any Universal Lighting Product does not meet the warranty specified above, Universal will provide a replacement lighting product. Universal extends this limited warranty to the first end-user purchaser only. This warranty is conditional based upon proper storage, installation, use and maintenance. This warranty is not applicable to, and Universal makes no warranty whatsoever with respect to, any Lighting Product not installed and operated in accordance with the National Electric Code (NEC), the Standards for Safety of Underwriters Laboratories, Inc. (UL), Standards for the American National Standards Institute (ANSI), in Canada, the Canadian Standards Association (CSA), or the International Electrotechnical Commission (IEC). Nor is this warranty applicable to any Lighting Product which has not been installed and operated in accordance with Universal’s specifications and connection diagrams or Lighting Products which have been submitted to abnormal operating conditions. This includes, but is not limited to, excessive temperatures as specified in Universal’s published literature. The conditions for any tests (to be) performed on Lighting Products which are claimed to have not performed in accordance with the terms of the warranty shall be mutually agreed upon in writing and Universal may be represented at any such tests. NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY BEYOND THE AFOREMENTIONED WARRANTY PERIOD. The foregoing warranty is exclusive of all other statutory, written or oral warranties and no other warranties of any kind, statutory or otherwise, are given or herein expressed. Warranty claims are to be made in accordance with Universal’s published Warranty Service Program, which is available upon request. This warranty sets forth Universal’s obligations and responsibilities regarding its Lighting Products and is the exclusive remedy available to the claimant. LIMITATIONS OF LIABILITY. Under no circumstances, whether as a result of breach of contract, breach of warranty, tort, strict liability or otherwise, will Universal be liable for consequential, incidental, special or exemplary damages, including, but not limited to, loss of profits, loss of use or damage to any property or equipment, cost of capital, cost of substitute product, facilities or services, down time costs or claims of claimant’s customers. Universal’s liability for all claims of any kind or for any loss or damages arising out of, resulting from or concerning any aspect of this warranty or from the Lighting Products or services furnished hereunder, shall not exceed the price of the specific Lighting Product which gives right to the claim, except in accordance with Universal’s Technical Engineering Service Program. STATE LAW RIGHT. Some states do not allow the exclusion or limitation of consequential or incidental damages or the duration of time for an implied warranty. Therefore, the limitations or exclusions of consequential or incidental damage and implied warranties may not apply to certain claimants. This warranty provides the claimant with specific legal rights and claimants may have other rights that vary from state to state. Universal Lighting Technologies, Inc. • 26 Century Blvd., Suite 500 • Nashville, Tennessee 37214-3683 • 1-800-BALLAST Form No. LPGWTY0410 IT’S EASY TO REACH US... Universal Lighting Technologies, Inc. 26 Century Blvd., Suite 500 Nashville, TN 37214-3683 General Info: (615) 316-5100 For Technical Engineering Services (TES), application support and warranty information, call 1-800-BALLAST Website: Email: webmaster@unvlt.com Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group All specification information is subject to change without notification. ULTNAV0710
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23 Modify Date : 2010:07:22 09:07:31-05:00 Create Date : 2010:07:22 09:07:31-05:00 Metadata Date : 2010:07:22 09:07:31-05:00 Creator Tool : Adobe InDesign CS3 (5.0.4) Format : application/pdf Document ID : uuid:e740228c-2912-c340-bb68-d14ef7defdb8 Instance ID : uuid:add1a082-a1a3-2845-a7e6-44cc7be7ee0f Producer : Adobe PDF Library 8.0 Page Count : 195 Creator : Adobe InDesign CS3 (5.0.4) Trapped : FalseEXIF Metadata provided by EXIF.tools