INDUSTRIAL

SERVING INDUSTRIAL, SPECIALTY AND
COMMERCIAL APPLICATIONS

J U N E 2 013

Industrial
Servicing Industrial,
Commercial and Specialty
Applications
This catalog contains in-depth
information on the most
comprehensive line of
instrumentation, power and
control cable available today.
It features the latest information
on products, along with detailed
technical and specification data
in indexed sections — with an
easy-to-use “spec-on-a-page”
format.
The “spec-on-a-page” format
was developed to meet your
needs. It features up-to-theminute product information,
from applications and
constructions to detailed
technical and specification
data. There’s also a glossary of
technical terms for additional
assistance.
And, of course, if you need any
further data, General Cable’s
Customer Service staff provides
the answers you need quickly
and efficiently.

What’s New?
BUILDING WIRE

Building wire is the most frequently specified wiring solution
today for commercial and residential construction projects.
General Cable offers a complete line of copper and aluminum alloy
building wire to serve virtually all the requirements of the electrical
industry. Our aluminum alloy building wire line consists of service
entrance cables for residential applications and power distribution
feeder cables for commercial, institutional and industrial
construction applications. Find out more about General Cable's
STABILOY® and NUAL® Brands of aluminum alloy cables.

G LO BA L O IL A N D G AS SO LU T I O N S
From exploration and extraction to production and processing
of natural resources, General Cable’s products satisfy virtually
every cabling requirement around the globe.

H A R N E S S I N G T H E R E N E WA B L E P O W E R
OF THE SUN
General Cable has the offering to comprise a complete cable
solution for solar power applications. From low-voltage DC and
AC connections and medium-voltage distribution to high-voltage
overhead and underground transmission lines, General Cable’s
range of products is engineered to withstand the demands of
entire solar power generation, transmission and distribution
systems — from the sun to the outlet.

All information in this catalog is presented solely
as a guide to product selection and is believed
to be reliable. All printing errors are subject to
correction in subsequent releases of this catalog.
Although General Cable has taken precautions to
ensure the accuracy of the product specifications
at the time of publication, the specifications of all
products contained herein are subject to change
without notice.
GENERAL CABLE, ARCTIC-FLEX, CCW, CHTC,
CVTC, DURAFLEX, DURALOX, DURASHEATH,
EHTC, FLEXFOIL, FREP, GENFREE, NVN, PNH,
PVIC, STRANDFILL, SUNGEN, SUPER VUTRON, VERTITECK, VNTC, UNIBLEND, UNICON
and UNISHIELD are trademarks of General Cable
Technologies Corporation.
©	2013. General Cable Technologies Corporation.
Highland Heights, KY 41076
All rights reserved.	
Printed in USA.

D E L I V E R I N G T H E R E N E WA B L E P O W E R
O F W I N D E N E R GY
General Cable has the offering to comprise a complete cable
solution for wind power applications. From optical fiber and
grounding wires for SCADA systems, low-voltage DC and AC
connections and medium-voltage distribution to high-voltage
overhead, underground and submarine transmission lines,
General Cable has the range of products engineered to withstand
the demands of entire wind power generation, transmission and
distribution systems — from the wind to the outlet.

PRODUCT SELECTION LOCATOR
SECTION

SPECIFICATION

1

300 V Instrumentation Cables

1000

2

600 V Instrumentation Cables

2000

3

600 V Flexible Control and Power Cables

3000

4

600 V Multi-Conductor Control and Power Cables

4000

5

600 V — 2 kV Industrial Power Cables

5000

6

2.4 kV — 35 kV Industrial Medium-Voltage Cables

6000

7

600 V — 35 kV Industrial Armored Cables

7000

8

600 V — 28 kV TECK90 Armored Control and Power Cables

8000

9

300 V — 35 kV CCW Armored Cables for Hazardous Locations 9000

	 Technical Information

®

A–F

Phone: 888-593-3355
www.generalcable.com

Table of Contents
Section 1

Date of Issue 06/13

300 V Instrumentation Cables

SPECIFICATION NO.

1050

CHTC®

1100

CHTC®

1150

CVTC®

1200

CVTC®

1250†

PVIC®

1300†

PVIC®

1350

PVIC®

PRODUCT DESCRIPTION

XLPE/XL-CPE, Instrumentation, Shielded
300 V, UL Type PLTC, Overall Shielded Pairs/Triads
XLPE/XL-CPE, Instrumentation, Shielded
300 V, UL Type PLTC, Individual and Overall Shielded Pairs
XLPE/PVC, Instrumentation, Shielded
300 V, UL Type PLTC, Overall Shielded Pairs/Triads
XLPE/PVC, Instrumentation, Shielded
300 V, UL Type PLTC, Individual and Overall Shielded Pairs
PVC/PVC, Instrumentation, Shielded
300 V, UL Type PLTC/ITC, Overall Shielded Pairs/Triads
PVC/PVC, Instrumentation, Shielded
300 V, UL Type PLTC/ITC, Individual and Overall Shielded Pairs
PVC/PVC, Instrumentation, Shielded
300 V, UL Type PLTC/ITC, Individual and Overall Shielded Triads

Section 2

600 V Instrumentation Cables

SPECIFICATION NO.
2050†
CHTC®

PRODUCT DESCRIPTION

2100†

FREP®

2150†

FREP®

2200

FREP®

2250

Arctic-Flex®

2300

Arctic-Flex®

2350

CVTC®

2400

CVTC®

2450†

VNTC®

2500†

VNTC®

2600†

GenFree®

2625†

GenFree®

2650

GenFree®

XLPE/XL-CPE, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Pairs/Triads
FR-EPR/CPE, Instrumentation, Shielded
600 V, UL Type TC, Overall Shielded Pairs/Triads
FR-EPR/CPE, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Pairs
FR-EPR/CPE, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Triads
XLPE/ARCTIC-PVC, Instrumentation, Shielded
600 V, UL Type TC, CSA Type CIC, Overall Shielded Pairs/Triads
XLPE/ARCTIC-PVC, Instrumentation, Shielded
600 V, UL Type TC, CSA Type CIC, Individual and Overall Shielded Pairs
XLPE/PVC, Instrumentation, Shielded
600 V, UL Type TC, Overall Shielded Pairs/Triads
XLPE/PVC, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Pairs
PVC/Nylon/PVC, Instrumentation, Shielded
600 V, UL Type TC, Overall Shielded Pairs/Triads
PVC/Nylon/PVC, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Pairs
XLPE/LSZH, Instrumentation, Shielded
600 V, UL Type TC-LS, Overall Shielded Pairs/Triads
XLPE/LSZH, Instrumentation, Shielded
600 V, UL Type TC-LS, Individual and Overall Shielded Pairs
XLPE/LSZH, Instrumentation, Shielded
600 V, UL Type TC-LS, Individual and Overall Shielded Triads

Section 3

600 V Flexible Control and Power Cables

SPECIFICATION NO.

PRODUCT DESCRIPTION

3150

NVN®

3250

MTW

3300

Festoon

Phone: 888-593-3355
www.generalcable.com

PVC/Nylon/Neoprene, Thermoset Flexible Control
600 V, UL Type TC
PVC/Nylon/PVC, Thermoplastic Flexible Control
600 V, UL Type MTW/CSA AWM
PVC/PVC, Thermoplastic Extreme Flexing Festoon Control and Power
600 V, UL/CSA Type Festoon

REVISION DATE

Mar. 2012
Mar. 2012

Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012

REVISION DATE

Mar. 2012

Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012

REVISION DATE

Jan. 2010

Jan. 2010
Jan. 2010

†Indicates these products are stocked by General Cable

Table of Contents

Date of Issue 06/13

Section 4

600 V Multi-Conductor Control and Power Cables

SPECIFICATION NO.
4050†
CHTC®

PRODUCT DESCRIPTION

4075†

CHTC®

4100†

CHTC®

4150

EHTC®

4200

EHTC®

4250

EHTC®

4300†

FREP®

4310†

FREP®

4325†

FREP®

4350†

FREP®

4400

Arctic-Flex®

4450

Arctic-Flex®

4460

CCTC™

4480

CCTC™

4500†

CVTC®

4550†

CVTC®

4575

CVTC® VFD

4580†

CVTC® VFD

4600†

VNTC®

4650†

VNTC®

4700†

VNTC®

4750†

VNTC®

4775†

TC-Flex™

4780†

TC-Flex™

XLPE/XL-CPE, Control, Unshielded
600 V, UL Type TC—E-2 Color Code
XLPE/XL-CPE, Control, Unshielded
600 V, UL Type TC—E-1 Color Code
XLPE/XL-CPE, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER—Method 4 Color Code
FR-EPR/XL-CPE, Control, Unshielded
600 V, UL Type TC (18 AWG/16 AWG)—E-2 Color Code
FR-EPR/XL-CPE, Control, Unshielded
600 V, UL Type TC (14 AWG—10 AWG)—E-2 Color Code
FR-EPR/XL-CPE, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER—Method 4 Color Code
FR-EPR/CPE, Control, Unshielded
600 V, UL Type TC-ER—E-2 Color Code
FR-EPR/CPE, Control, Unshielded
600 V, UL Type TC-ER—E-1 Color Code
FR-EPR/CPE, Control, Shielded
600 V, UL Type TC-ER, Overall Shielded—E-2 Color Code
FR-EPR/CPE, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER—Method 4 Color Code
XLPE/Arctic-PVC, Control, Unshielded
600 V, UL Type TC-ER, CSA Type RW90 XLPE, CSA Type TC
XLPE/Arctic-PVC, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER, CSA Type RW90 XLPE, CSA Type TC
FR-XLPE/CPE, Control, Shielded
600 V, UL Type TC-ER—E-1 Color Code
FR-XLPE/CPE, Low-Voltage Power, Shielded
600 V, UL Type TC-ER—Method 4 Color Code
XLPE/PVC, Control, Unshielded
600 V, UL Type TC-ER—E-2 Color Code
XLPE/PVC, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER—Method 4 Color Code
XLPE/PVC, Low-Voltage Power, Shielded
2000 V, UL Type TC-ER—Method 4 Color Code
XLPE/PVC, Low-Voltage Power, Copper Tape Shielded
2000 V, UL Type TC-ER—Method 4 Color Code
PVC/Nylon/PVC, Control, Unshielded
600 V, UL Type TC-ER (18 AWG/16 AWG)—E-2 Color Code
PVC/Nylon/PVC, Control, Unshielded
600 V, UL Type TC-ER (14 AWG—10 AWG)—E-2 Color Code
PVC/Nylon/PVC, Control, Shielded
600 V, UL Type TC-ER, Overall Shielded—E-2 Color Code
PVC/Nylon/PVC, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER—Method 4 Color Code
18 AWG (1,0 mm²)—16 AWG (1,5 mm²)
UL Type WTTC 1000 V or Type TC-ER 600 V or Type MTW and c(UL) CIC/TC
600 V FT4 or CSA AWM 90°C 1000 V
14 AWG (2,5 mm²)–10 AWG (6,0 mm²)
UL Type WTTC 1000 V or Type TC-ER 600 V or Type MTW and c(UL) CIC/TC
600 V FT4 or CSA AWM 90°C 1000 V

†Indicates these products are stocked by General Cable

REVISION DATE

Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012

Aug. 2012
Mar. 2012
Mar. 2012
Jun. 2012
Jun. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Jun. 2013
Jun. 2013

Phone: 888-593-3355
www.generalcable.com

Table of Contents
Section 4

(cont’d.)

SPECIFICATION NO.
4785†
TC-Flex™

4790†

TC-Flex™

4800

20/10

4850

20/10

4900†

GenFree®

4925

GenFree®

4950†

GenFree®

Date of Issue 06/13

600 V Multi-Conductor Control and Power Cables
PRODUCT DESCRIPTION

18 AWG (1,0 mm²)—16 AWG (1,5 mm²)
UL Type WTTC 1000 V or Type TC-ER 600 V or Type MTW and c(UL) CIC/TC
600 V FT4 or CSA AWM 90°C 1000 V
14 AWG (2,5 mm²)—4 AWG (35,0 mm²)
UL Type WTTC 1000 V or Type TC-ER 600 V or Type MTW and c(UL) CIC/TC
600 V FT4 or CSA AWM 90°C 1000 V
PE/PVC/PVC, Control, Unshielded
600 V (18 AWG/16 AWG)—E-1 Color Code
PE/PVC/PVC, Control, Unshielded
600 V (14 AWG—10 AWG)—E-1 Color Code
XLPE/LSZH, Control
600 V, UL Type TC-LS-ER—E-2 Color Code
XLPE/LSZH, Control, Shielded
600 V, UL Type TC-LS-ER, Overall Shielded—E-2 Color Code
XLPE/LSZH, Low-Voltage Power, Unshielded
600 V, UL Type TC-LS-ER—Method 4 Color Code

Section 5

600 V – 2 kV Industrial Power Cables

SPECIFICATION NO.
5050†
DuraSheath®

PRODUCT DESCRIPTION

5075

GenFree® II

5100

Unicon® FREP®

5125

GenFree® II

5150†

XHHW-2 VW-1

5175†

XHHW-2 CT

5250†

Unicon® XLPE

5275

GenFree® II

5290†

THHN/THWN-2

5300

Super Vu-Tron®

5310†

Diesel Locomotive
Cable

5350†

GenFree® LSZH

5400

GenFree® LSZH

5700†

RHH/RHW-2

5790

EPR/XL-CPE, Low-Voltage Power, Unshielded
600 V, UL Type RHH/RHW-2/USE-2
LSZH XLPO/LSZH XLPO, Low-Voltage Power, Unshielded
600 V, UL Type RHH/RHW-2/USE-2
FR-EPR, Low-Voltage Power, Unshielded
600 V, UL Type RHH/RHW-2/USE-2
LSZH XLPO, Low-Voltage Power, Unshielded
600 V, UL Type XHHW-2
XLPE, Control and Low-Voltage Power
600 V, UL Type SIS/XHHW-2, VW-1 Rated
XLPE, Low-Voltage Power
600 V, UL Type XHHW-2, CT Rated, Single Conductor, Copper
XLPE, Low-Voltage Power
600 V, UL Type RHH/RHW-2/USE-2
LSZH XLPO, Low-Voltage Power, Unshielded
600 V, UL Type RHH/RHW-2/USE-2
PVC, Low-Voltage Power
600 V, UL Type THHN/THWN-2, Single Conductor, Copper
EPR/CPE, Diesel Locomotive Cable
90°C, 2000 V, DLO, UL Type RHH/RHW, 600 V, CSA Type R90, 1000 V
2000 Volts (EPR/XL-CPE), UL RHH/RHW-2 2000 V and c(UL) RW90 1000 V
Flexible, Oil-, Sunlight- and Ozone-Resistant, Flame-Retardant, -40°C to 90°C

REVISION DATE

Jun. 2013
Jun. 2013
Jul. 2010
Jul. 2010
Oct. 2012
Oct. 2012
Oct. 2012

REVISION DATE

Mar. 2012

Jun. 2013
Jan. 2010
Jun. 2013
Oct. 2012
Jan. 2013
Oct. 2012
Jun. 2013
Oct. 2012
Mar. 2012
May 2012

DISCONTINUED
DISCONTINUED

Sept. 2013

XLPE, Low-Voltage Power, Unshielded
2000 V, UL Type RHH/RHW-2, Single Conductor, Aluminum
SunGen® Global XLPE/LSZH XLPO, Photovoltaic Wire, TÜV 2 pfg
1169/08.2007 PV1-F AC Uo/U 0.6/1 kV, UL 4703, PV Wire 2000 V

Mar. 2012

Phone: 888-593-3355
www.generalcable.com

Sept. 2013

May 2012

†Indicates these products are stocked by General Cable

Table of Contents
Section 5

(cont’d.)

SPECIFICATION NO.
5800†
SunGen®

5800A
5810†
5810A
5840†
5840A
5845†
5850†
5850A
5855†
5880†
5890†

Date of Issue 06/13

600 V – 2 kV Industrial Power Cables
PRODUCT DESCRIPTION

Dual-Layer EPR/XL-CPE, Photovoltaic Wire
600 V, UL Type PV/USE-2/RHH or RHW-2, Single Conductor, Copper
Dual-Layer EPR/XL-CPE, Photovoltaic Wire
SunGen®
600 V, UL Type PV/USE-2/RHH or RHW-2, Single Conductor, Aluminum
SunGen®
Dual-Layer EPR/XL-CPE, Photovoltaic Wire
2000 V, UL Type PV/RHH or RHW-2 or 600 V USE-2, Single Conductor, Copper
Dual-Layer EPR/XL-CPE, Photovoltaic Wire
SunGen®
2000 V, UL Type PV/RHH or RHW-2 or 600 V USE-2, Single Conductor, Aluminum
SunGen®
XLPE, Photovoltaic Wire
600 V, UL Type PV/USE-2 or 2000 V RHH or RHW-2 or CSA RPVU90
1000 V, Single Conductor, Copper
XLPE, Photovoltaic Wire
SunGen®
600 V, UL Type PV/USE-2 or 2000 V RHH or RHW-2 or CSA RPVU90
1000 V, Single Conductor, Aluminum
SunGen® IC XLPE, Photovoltaic Wire
600 V, UL Type PV/USE-2 or 2000 V RHH or RHW-2 or CSA RPVU90
1000 V, Single Conductor, Copper
SunGen®
XLPE, Photovoltaic Wire
2000 V, UL Type PV/RHH or RHW-2 or 600 V USE-2 or CSA RPVU90
1000 V, Single Conductor, Copper
XLPE, Photovoltaic Wire
SunGen®
2000 V, UL Type PV/RHH or RHW-2 or 600 V USE-2 or CSA RPVU90
1000 V, Single Conductor, Aluminum
SunGen® IC XLPE, Photovoltaic Wire
2000 V, UL Type PV/RHH or RHW-2 or 600 V USE-2 or CSA RPVU90
1000 V, Single Conductor, Copper
SunGen® MI XLPE/PVC, AC Micro-Inverter Cable
600 V, UL Type TC-ER
SunGen® MI-LS XLPO/LSZH, AC Micro-Inverter Cable
600 V, UL Type TC-LS-ER

Section 6

2.4 kV – 35 kV Industrial Medium-Voltage Cables

SPECIFICATION NO.
6050†
DuraSheath®

PRODUCT DESCRIPTION

6100†
6150
6155†
6160†
6175
6180†
6200
6250

EPR/XL-CPE, Medium-Voltage Power, Nonshielded
2400 V, UL Type MV-90
UniShield® EPR/Copper Wire Shield/CPE, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils
EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
Uniblend®
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils
Uniblend® LF EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils
Aluminum
EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
Uniblend® LF 5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils
EPR/Copper Tape Shield/CPE, Medium-Voltage Power, Shielded
Uniblend®
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils
GenFree®
EPR/Copper Tape Shield/LSZH, Medium-Voltage Power, Shielded
Uniblend®
5 kV and 8 kV, UL Type MV-105/ST1, 133%/100% Ins. Levels, 115 Mils
Copper Wire TRXLPE/Copper Wire Shield/PVC, Medium-Voltage Power
Shield
5 kV, UL Type MV-105, 100% Ins. Level, 90 Mils
EPR/Copper Tape Shield with Overall PVC Jacket
Uniblend®
Medium-Voltage Power, Shielded, 5 kV and 8 kV, UL Type MV-105
133%/100% Ins. Levels, 115 Mils, Three Conductor

†Indicates these products are stocked by General Cable

REVISION DATE

May 2012
Oct. 2012
May 2012
Oct. 2012
May 2012
Oct. 2012

May 2012
May 2012
Oct. 2012
May 2012
May 2012
May 2012

REVISION DATE

Aug. 2011
Jun. 2013
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Jan. 2011
Mar. 2012

Phone: 888-593-3355
www.generalcable.com

Table of Contents
Section 6

(cont’d.)

SPECIFICATION NO.
6255†
Uniblend®

6275
6280
6300†
6350
6355†
6360†
6375
6380†
6400
6450
6455†
6475
6480
6500
6550
6555†
6560
6575
6580
6600

Date of Issue 06/13

2.4 kV – 35 kV Industrial Medium-Voltage Cables
PRODUCT DESCRIPTION

LF EPR/Copper Tape Shield with Overall PVC Jacket
Medium-Voltage Power, Shielded, 5 kV and 8 kV, UL Type MV-105
133%/100% Ins. Levels, 115 Mils, Three Conductor
EPR/Copper Tape Shield with Overall CPE Jacket
Uniblend®
Medium-Voltage Power, Shielded, 5 kV and 8 kV, UL Type MV-105
133%/100% Ins. Levels, 115 Mils, Three Conductor
EPR/Copper Tape Shield with Overall LSZH Jacket
GenFree®
Uniblend®
Medium-Voltage Power, Shielded, 5 kV and 8 kV, UL Type MV-105
133%/100% Ins. Levels, 115 Mils, Three Conductor
UniShield® EPR/Copper Wire Shield/CPE, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils
EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
Uniblend®
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils
Uniblend® LF EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils
Aluminum
EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
Uniblend® LF 15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils
EPR/Copper Tape Shield/CPE, Medium-Voltage Power, Shielded
Uniblend®
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils
GenFree®
EPR/Copper Tape Shield/LSZH, Medium-Voltage Power, Shielded
Uniblend®
15 kV, UL Type MV-105/ST1, 133% Ins. Level, 220 Mils
Copper Wire TRXLPE/Copper Wire Shield/PVC, Medium-Voltage Power
Shield
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils
EPR/Copper Tape Shield with Overall PVC Jacket
Uniblend®
Medium-Voltage Power, Shielded, 15 kV, UL Type MV-105
133% Ins. Level, 220 Mils, Three Conductor
Uniblend® LF EPR/Copper Tape Shield with Overall PVC Jacket
Medium-Voltage Power, Shielded, 15 kV, UL Type MV-105
133% Ins. Level, 220 Mils, Three Conductor
EPR/Copper Tape Shield with Overall CPE Jacket
Uniblend®
Medium-Voltage Power, Shielded, 15 kV, UL Type MV-105
133% Ins. Level, 220 Mils, Three Conductor
EPR/Copper Tape Shield with Overall LSZH Jacket
GenFree®
Uniblend®
Medium-Voltage Power, Shielded, 15 kV, UL Type MV-105
133% Ins. Level, 220 Mils, Three Conductor
UniShield® EPR/Copper Wire Shield/CPE, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils
EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
Uniblend®
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils
Uniblend® LF EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils
Aluminum
EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
Uniblend® LF 25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils
EPR/Copper Tape Shield/CPE, Medium-Voltage Power, Shielded
Uniblend®
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils
EPR/Copper Tape Shield/LSZH, Medium-Voltage Power, Shielded
GenFree®
Uniblend®
25 kV and 35 kV, UL Type MV-105/ST1, 133%/100% Ins. Levels, 345 Mils
EPR/Copper Tape Shield with Overall PVC Jacket
Uniblend®
Medium-Voltage Power, Shielded, 25 kV and 35 kV, UL Type MV-105
133%/100% Ins. Levels, 345 Mils, Three Conductor

Phone: 888-593-3355
www.generalcable.com

REVISION DATE

Mar. 2012

Mar. 2012
Mar. 2012
Jun. 2013
Mar. 2012
Apr. 2011
Apr. 2011
Apr. 2011
Mar. 2012
Jan. 2011
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Jun. 2013
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012

†Indicates these products are stocked by General Cable

Table of Contents
Section 6

(cont’d.)

SPECIFICATION NO.

6605

6650
6655
6660

2.4 kV – 35 kV Industrial Medium-Voltage Cables
PRODUCT DESCRIPTION

Uniblend® LF EPR/Copper Tape Shield with Overall PVC Jacket
Medium-Voltage Power, Shielded, 25 kV and 35 kV, UL Type MV-105
133%/100% Ins. Levels, 345 Mils, Three Conductor
EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
Uniblend®
35 kV, UL Type MV-105, 133% Ins. Levels, 420 Mils
Uniblend® LF EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
35 kV, UL Type MV-105, 133% Ins. Levels, 420 Mils
Aluminum
EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
Uniblend® LF 35 kV, UL Type MV-105, 133% Ins. Levels, 420 Mils

Section 7

600 V – 35 kV Industrial Armored Cables

SPECIFICATION NO.
7050†
Duralox®

PRODUCT DESCRIPTION

7100†

Duralox®

7150†

Duralox®

7160†

Duralox®

7200†

Duralox®

7250†

Duralox®
Uniblend®
Duralox®
Uniblend®
Duralox®
Uniblend®
Duralox®
Uniblend®
Duralox®
Uniblend®

7300†
7310†
7350
7400

Date of Issue 06/13

XLPE/AIA/PVC, Control, Armored
600 V, UL Type MC, Multi-Conductor
XLPE/AIA/PVC, Power, Armored
600 V, UL Type MC, Three and Four Conductor (8 AWG - 4/0 AWG)
XLPE/AIA/PVC, Power, Armored
600 V, UL Type MC, Three and Four Conductor (250 kcmil - 1000 kcmil)
XLPE/AIA/PVC, Power, Armored, with Enhanced Ground Wires (50%)
600 V, UL Type MC, Three Conductor (1/0 AWG - 1000 kcmil)
EPR/AIA/PVC, Power, Nonshielded, Armored
2400 V, UL Type MV-90 or MC, Three Conductor
EPR/AIA/PVC, Power, Shielded, Armored
5 kV/8 kV, UL Type MV-105 or MC, 133%/100% Ins. Levels, 115 Mils, Three Conductor
EPR/AIA/PVC, Power, Shielded, Armored
15 kV, UL Type MV-105 or MC, 133% Ins. Level, 220 Mils, Three Conductor
EPR/AIA/PVC, Power, Shielded, Armored, with Enhanced Ground Wires (50%)
15 kV, UL Type MV-105 or MC, 133% Ins. Level, 220 Mils, Three Conductor
EPR/AIA/PVC, Power, Shielded, Armored
25 kV, UL Type MV-105 or MC, 100% Ins. Level, 260 Mils, Three Conductor
EPR/AIA/PVC, Power, Shielded, Armored
35 kV, UL Type MV-105 or MC, 100% Ins. Level, 345 Mils, Three Conductor

REVISION DATE

Mar. 2012
Apr. 2011
Apr. 2011
Apr. 2011

REVISION DATE

Jan. 2010
Jun. 2013
Jun. 2013
Jun. 2013
Jan. 2010

Aug. 2010
Aug. 2010
Aug. 2010
Aug. 2010
Aug. 2010

Section 8

600 V – 28 kV TECK90 Armored Control and Power Cables

SPECIFICATION NO.
8025†
TECK90

PRODUCT DESCRIPTION

8050†

TECK90

8075†

TECK90

8100

TECK90

8125

TECK90

8150†

TECK90

8175†

TECK90

XLPE/PVC/AIA/PVC, Control, Armored
600 V, CSA TECK90, Multi-Conductor, 14 AWG
XLPE/PVC/AIA/PVC, Control, Armored
600 V, CSA TECK90, Multi-Conductor, 12 AWG
XLPE/PVC/AIA/PVC, Control, Armored
600 V, CSA TECK90, Multi-Conductor, 10 AWG
XLPE/PVC/AIA/PVC, Power, Armored
1000 V, CSA TECK90, Single Conductor
XLPE/PVC/AIA/PVC, Control and Power, Armored
1000 V, CSA TECK90, Two Conductor
XLPE/PVC/AIA/PVC, Control and Power, Armored
1000 V, CSA TECK90, Three Conductor
XLPE/PVC/AIA/PVC, Control and Power, Armored
1000 V, CSA TECK90, Four Conductor

†Indicates these products are stocked by General Cable

REVISION DATE

Mar. 2012

Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012
Mar. 2012

Phone: 888-593-3355
www.generalcable.com

Table of Contents
Section 8

(cont’d.)

SPECIFICATION NO.

8200

TECK90

8225

TECK90

8250†

TECK90

8275

HVTECK

8300

HVTECK

8325

HVTECK

8350

HVTECK

8375

HVTECK

8400

HVTECK

8425

HVTECK

8450†

HVTECK

8475

HVTECK

8500

HVTECK

8525

HVTECK

8550

VERTITECK®
TECK90
VERTITECK®
TECK90
VERTITECK®
HVTECK
VERTITECK®
HVTECK

8575
8600
8625
8700†

ACWU

8750†

ACWU

8775†

ACWU

Phone: 888-593-3355
www.generalcable.com

Date of Issue 06/13

600 V – 28 kV TECK90 Armored Control and Power Cables
PRODUCT DESCRIPTION

XLPE/PVC/AIA/PVC, Power/Control Composite
600 V, CSA TECK90, Three Power and Three 14 AWG Control Conductors
XLPE/PVC/AIA/PVC, Power, Unshielded, Armored
5 kV, CSA TECK90, 100%/133% Ins. Levels, Single Conductor
XLPE/PVC/AIA/PVC, Power, Unshielded, Armored
5 kV, CSA TECK90, 100%/133% Ins. Levels, Three Conductor
TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored
5 kV, CSA HVTECK, 100%/133% Ins. Levels, 90 Mils, Single Conductor
TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored
5 kV, CSA HVTECK, 133% Ins. Level, 115 Mils, Single Conductor
TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
5 kV, CSA HVTECK, 100%/133% Ins. Levels, 90 Mils, Three Conductor
TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
5 kV, CSA HVTECK, 133% Ins. Level, 115 Mils, Three Conductor
TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 100% Ins. Level, 175 Mils, Single Conductor
TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 133% Ins. Level, 220 Mils, Single Conductor
TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 100% Ins. Level, 175 Mils, Three Conductor
TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 133% Ins. Level, 220 Mils, Three Conductor
TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
25 kV, CSA HVTECK, 100% Ins. Level, 260 Mils, Three Conductor
TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
25 kV, CSA HVTECK, 133% Ins. Level, 320 Mils, Three Conductor
TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
28 kV, CSA HVTECK, 133% Ins. Level, 345 Mils, Three Conductor
XLPE/PVC/GSIA/PVC, Power, Unshielded, Armored
1 kV, CSA TECK90, Three Conductor
XLPE/PVC/GSIA/PVC, Power, Unshielded, Armored
5 kV, CSA TECK90, 90 Mils, Three Conductor
TRXLPE/Tape Shield/PVC/GSIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 133% Ins. Level, 220 Mils, Three Conductor
TRXLPE/Tape Shield/PVC/GSIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 100% Ins. Level, 175 Mils, Three Conductor
XLPE/AIA/PVC, Control, Armored
600 V, CSA ACWU90 (-40˚C), Single Conductor
XLPE/AIA/PVC, Control, Armored
600 V, CSA ACWU90 (-40˚C), Three Conductor
XLPE/AIA/PVC, Control, Armored
600 V, CSA ACWU90 (-40˚C), Four Conductor

REVISION DATE

Mar. 2012
Oct. 2012
Jun. 2013
Oct. 2012
Oct. 2012
Oct. 2012
Oct. 2012
Oct. 2012
Oct. 2012
Oct. 2012
Oct. 2012
Oct. 2012
Oct. 2012
Oct. 2012
Jan. 2010
Oct. 2012
Oct. 2012
Oct. 2012

Mar. 2012
Mar. 2012
Mar. 2012

†Indicates these products are stocked by General Cable

Table of Contents
Section 9

300 V - 35 kV CCW® Armored Cables for Hazardous Locations

SPECIFICATION NO.

9025
9050
9075
9125
9150
9225
9250
9325
9350
9500
9510
9525
9600
9615
9625
9650
9675
9700
9800
9815
9825
9835
9845
9855
9875
9900

Date of Issue 06/13

CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor
CCW®
Armor

PRODUCT DESCRIPTION

Thermocouple Extension, Single Pair, Overall Shield (OS)
UL Type ITC-HL/PLTC, PVC, 105°C, ABS CWCMC
Thermocouple Extension, Pairs, Overall Shield (OS)
UL Type ITC-HL/PLTC, PVC, 105°C, ABS CWCMC
Thermocouple Extension, Pairs, Individual and Overall Shield (IS-OS)
UL Type ITC-HL/PLTC, PVC, 105°C, ABS CWCMC
300 V Instrumentation, Pairs/Triads, Overall Shield (OS)
UL Type ITC-HL/PLTC, XLPE, 90°C, ABS CWCMC
300 V Instrumentation, Pairs/Triads, Individual and Overall Shield (IS-OS)
UL Type ITC-HL/PLTC, XLPE, 90°C, ABS CWCMC
300 V Instrumentation, Pairs/Triads, Overall Shield (OS)
UL Type ITC-HL/PLTC, PVC, 105°C, ABS CWCMC
300 V Instrumentation, Pairs/Triads, Individual and Overall Shield (IS-OS)
UL Type ITC-HL/PLTC, PVC, 105°C, ABS CWCMC
600 V Instrumentation, Pairs/Triads, Overall Shield (OS)
UL Type MC-HL, PVC/Nylon, 90°C, ABS CWCMC
600 V Instrumentation, Pairs/Triads, Individual and Overall Shield (IS-OS)
UL Type MC-HL, PVC/Nylon, 90°C, ABS CWCMC
600 V Control With Grounding Conductor
UL Type MC-HL, XLPE, 90°C, ABS CWCMC
600 V Control With Bare Grounding Conductor
UL Type MC-HL, XLPE, 90°C, ABS CWCMC
600 V Control Without Grounding Conductor
UL Type MC, XLPE, 90°C, ABS CWCMC
600 V Power, 3/C VFD and 4/C
UL Type MC-HL, XLPE, 90°C, ABS CWCMC
2000 V Power, 3/C VFD
UL Type MC-HL, XLPE, 90°C, ABS CWCMC
600 V Composite Power and Control
UL Type MC-HL, XLPE, 90°C, ABS CWCMC
600 V Composite Power and Control Without Ground
UL Type MC, XLPE, 90°C, ABS CWCMC
1000 V Power, 3/C VFD
CSA Type RA90, HL, XLPE, 90°C
2.4 kV Power, Nonshielded, 3/C VFD
UL Type MC-HL or MV-90, EPR, 90°C, ABS CWCMC
5 kV 133%/8 kV 100% Power, Shielded, 3/C VFD
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC
8 kV 133% Power, Shielded, 3/C VFD
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC
15 kV 100% Power, Shielded, 3/C
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC
15 kV 133% Power, Shielded, 3/C
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC
25 kV 100% Power, Shielded, 3/C
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC
25 kV 133%/35 kV 100% Power, Shielded, 3/C
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC
35 kV 133% Power, Shielded, 3/C
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC
CCW® Armored Cable Tool Kit

†Indicates these products are stocked by General Cable

REVISION DATE

Apr. 2011
Apr. 2011
Apr. 2011
Apr. 2011
Apr. 2011
Apr. 2011
Apr. 2011

Feb. 2011
Feb. 2011
Feb. 2011
Feb. 2011
Feb. 2011
Feb. 2011
Feb. 2011
Jan. 2011
Feb. 2011
Mar. 2012
Feb. 2011
May 2012
May 2012
May 2012
May 2012
May 2012
Feb. 2011
Feb. 2011
Jan. 2010

Phone: 888-593-3355
www.generalcable.com

Table of Contents

Date of Issue 06/13

Section A

General Technical Information

SPECIFICATION NO.

DESCRIPTION

A005

Glossary

Jan. 2010

A025

Reference Standards

Jan. 2010

A050

Checklist for Specifications

Jan. 2010

A075

NEC and CSA Designations

Jan. 2010

A100

Common Color Sequence

May 2013

A150

Metric Conversion Factors

Sept. 2010

A200

Reel Capacity Chart

Jan. 2012

Section B

Conductor Data

SPECIFICATION NO.

DESCRIPTION

B005

Conductor Reference

Jan. 2010

B025

Class B Conductors for General Wiring

Mar. 2012

B030

Class C Conductors for General Wiring

Feb. 2011

B035

Class H Conductors for General Wiring

Feb. 2011

B040

Class I Conductors for General Wiring

Mar. 2012

B045

Class K Conductors for General Wiring

Mar. 2012

Section C

Material Properties

SPECIFICATION NO.

DESCRIPTION

C005

Thermoplastic Jacket and Insulation Material Properties

Sept. 2012

C010

Thermoset Jacket and Insulation Material Properties

Jan. 2010

Section D

Handling and Storage Recommendations

SPECIFICATION NO.

DESCRIPTION

D005

Recommended Reel Handling Practices

May 2013

D025

Recommended Cable Handling Practices

Oct. 2011

D050

Recommended Cable Storage Practices

May 2013

Phone: 888-593-3355
www.generalcable.com

REVISION DATE

REVISION DATE

REVISION DATE

REVISION DATE

Table of Contents

Date of Issue 06/13

Section E

Cable Installation Guidelines

SPECIFICATION NO.

DESCRIPTION

E005

Pre-Installation Instructions

Apr. 2010

E025

Installation – Overview and Checklist

Jan. 2011

E050

Installation – Feed-In Setups

Apr. 2010

E075

Installation – Conductor Maximum Pulling Tensions

Oct. 2012

E100

Installation – Training and Bending Limitations

Apr. 2010

E125

Installation – Maximum Sidewall Pressure

Oct. 2012

Section F

Cable Testing

SPECIFICATION NO.

DESCRIPTION

F005

DC “HI-POT” Pre-Test Guidelines for MV Cables

Apr. 2010

F025

DC “HI-POT” Testing Guidelines for MV Cables

Apr. 2010

F075

Field Electrical “HI-POT” Testing Guidelines

Apr. 2010

F100

Emergency Overload Current Guidelines

Jan. 2010

F125

Short Circuit Current Calculation Overview

Jan. 2010

F150

Short Circuit Current for Copper Shields

Jan. 2010

F175

AC Resistance & Inductive Reactance

Jun. 2013

REVISION DATE

REVISION DATE

Phone: 888-593-3355
www.generalcable.com

Corporate Social Responsibility
C R E AT I N G S H A R E D VA L U E
General Cable believes corporate social responsibility (CSR) is about creating shared value. That
means keeping a dual focus in our business decisions: what is good for us as a company and what
contributes to the greater good of the communities in which we live and work.
SAFETY
Working safer by working together

General Cable has one worldwide safety vision and goal – ZERO & BEYOND. We
measure safety performance globally, share best practices and implement sound health
and safety management systems. Many of our facilities worldwide are OHSAS 18001
(safety management system) certified. All North American facilities have implemented
an equivalent health and safety management system. General Cable was a pioneer in
obtaining the OHSAS 18001 Certificate for Occupational Health and Safety Management
Systems in Europe and North Africa.

SUSTAINABILITY
Responsible practices in daily operations
As a global leader in the wire and cable industry, General Cable recognizes its role and
responsibility in promoting sustainability. Our strongest business value is continuous
improvement in all areas of our company. Across our many businesses, the quest to
introduce new and better products through continuous improvement in environmental
designs reflects our commitment to achieving industry-leading standards and responding
proactively to global environmental issues. General Cable was the first cable manufacturer
to obtain certification for its environmental management system, in accordance with the
ISO 14001 and EMAS Standards.

CITIZENSHIP
A commitment to being good citizens
Being responsible citizens in our communities is of the utmost importance to us.
Unequivocal honesty, integrity, forthrightness and fair dealing have long been part of
General Cable’s core values and are expected globally in all of our business relationships
with our customers, employees, suppliers, neighbors and competitors. Our company
leaders and employees strive to make a difference throughout a host of volunteer activities
and financial support, improving the communities in which we live and work.

INNOVATION
Technologies that power and connect the world
General Cable is delivering innovation that matters. We are focusing on R&D expertise and
investing in developing wire and cable solutions that meet the challenges confronting our
customers and the world. In working together and using all the ingenuity and creativity we
have, we will reach the goal of being the preeminent supplier of wire and cabling solutions
in the industry, both with green constructions and designs for the ever-growing renewable
energy market.

Visit www.GeneralCableCSR.com to learn more.
A commitment to achieving industry-leading standards
and responding proactively to environmental global issues.

+1.859.572.8000
info@generalcable.com

Making Contact with the World
Directing Traffic without Gridlock
Building Bridges in the Sky

General Cable is a leader in the
development, design, manufacture,
marketing and distribution of copper,
aluminum and fiber optic wire and cable
for the energy, industrial, specialty and
communications markets.

As one of the largest wire and cable manufacturers with more than
14,000 associates, 57 manufacturing facilities in 26 countries and
sales representation and distribution worldwide, we are truly
One Company Connecting the World.

Energy Cables
Our cables carry energy across the world — through the air,
underground and under the sea. Increasing demand for energy is
accelerating investment in exploration, extraction, power generation,
transmission and distribution — whether based on coal, natural gas,
oil, nuclear, wind, solar or water.

Our products inspire progress worldwide …

Industrial & Specialty Cables

customers use our value-added products
improves the standard of living for

Our cables channel the power and signals that make equipment hum
and engines run. From oil rigs and broadcast studios to cars and trains,
and in commercial buildings, public venues, factory floors and special
applications such as military, nuclear, marine and mining — we serve
an extensive range of markets.

people everywhere.

Communications Cables

to create global infrastructure that

innovative solutions and industry-leading

Our cables keep information flowing — facilitating a non-stop stream
of words and images around the world. We meet the high-speed
bandwidth needs of global communications networks, from fiber
optic submarine communications cables, copper and fiber aerial and
underground cables to copper and fiber optic enterprise cables and
system solutions.

products, expanding geographic access and

World Headquarters

Each day we’re building business
momentum — developing ideas into

furthering our investment in highly capable
associates, Lean Manufacturing, material
science and technology resources.

General Cable
4 Tesseneer Drive
Highland Heights, KY
41076-9753 U.S.A.

Date of Issue 06/13
Section 1		

Industrial Cables

300 V Instrumentation Cables
SPECIFICATION NO.

PRODUCT DESCRIPTION

REVISION DATE

1050

CHTC

XLPE/XL-CPE, Instrumentation, Shielded
300 V, UL Type PLTC, Overall Shielded Pairs/Triads

Mar. 2012

1100

CHTC®

XLPE/XL-CPE, Instrumentation, Shielded
300 V, UL Type PLTC, Individual and Overall Shielded Pairs

Mar. 2012

1150

CVTC®

XLPE/PVC, Instrumentation, Shielded
300 V, UL Type PLTC, Overall Shielded Pairs/Triads

Mar. 2012

1200

CVTC®

XLPE/PVC, Instrumentation, Shielded
300 V, UL Type PLTC, Individual and Overall Shielded Pairs

Mar. 2012

1250†

PVIC®

PVC/PVC, Instrumentation, Shielded
300 V, UL Type PLTC/ITC, Overall Shielded Pairs/Triads

Mar. 2012

1300†

PVIC®

PVC/PVC, Instrumentation, Shielded
300 V, UL Type PLTC/ITC, Individual and Overall Shielded Pairs

Mar. 2012

1350

PVIC®

PVC/PVC, Instrumentation, Shielded
300 V, UL Type PLTC/ITC, Individual and Overall Shielded Triads

Mar. 2012

†Indicates

®

these products are stocked by General Cable

Phone: 888-593-3355
www.generalcable.com

SPEC 1050

March, 2012

CHTC

®

XLPE/XL-CPE, Instrumentation, Shielded
300 V, UL Type PLTC, Overall Shielded Pairs/Triads
Product Construction:
Conductor:

• 20 AWG thru 16 AWG tinned, annealed copper per
ASTM B33
• Class B stranding per ASTM B8

Insulation:

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. OF COND.
THICKNESS
THICKNESS
CABLE
O.D.
PAIRS/ SIZE COND.
LBS/
LBS/
TRIADS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

1
1 TRI
2
4
8
12
16
20
24
36
50

20
20
20
20
20
20
20
20
20
20
20

7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121

0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012

0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30

0.035
0.035
0.040
0.040
0.050
0.050
0.060
0.060
0.060
0.070
0.070

0.89
0.89
1.02
1.02
1.27
1.27
1.52
1.52
1.52
1.78
1.78

0.230
0.240
0.320
0.370
0.500
0.575
0.665
0.740
0.795
1.005
1.175

5.84
6.10
8.13
9.40
12.70
14.61
16.89
18.80
20.19
25.53
29.85

9
13
17
31
60
89
118
148
177
264
365

14
19
25
47
90
133
176
220
263
392
544

27
33
48
73
138
186
248
300
350
525
697

40
49
71
109
205
277
369
446
521
781
1037

OVERALL SHIELDED PAIRS/TRIADS
18 AWG CONDUCTORS
337820*
337830*
337840*
337850*
337860*
337870*
337880*
337890*
337900*
337910*
337920*

1
1 TRI
2
4
8
12
16
20
24
36
50

18
18
18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.035
0.035
0.040
0.050
0.050
0.060
0.060
0.060
0.070
0.070
0.070

0.89
0.89
1.02
1.27
1.27
1.52
1.52
1.52
1.78
1.78
1.78

0.245
0.255
0.350
0.425
0.545
0.640
0.730
0.810
0.895
1.095
1.255

6.22
6.48
8.89
10.80
13.84
16.26
18.54
20.57
22.73
27.81
31.88

16
16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.035
0.035
0.050
0.050
0.060
0.060
0.060
0.060
0.070
0.070
0.080

0.89
0.89
1.27
1.27
1.52
1.52
1.52
1.52
1.78
1.78
2.03

0.270
0.285
0.430
0.490
0.650
0.755
0.845
0.900
1.020
1.225
1.415

6.86
7.24
10.92
12.45
16.51
19.18
21.46
22.86
25.91
31.12
35.94

Overall shielded pairs/triads
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire
• Lead-free Cross-linked Chlorinated Polyethylene
(XL-CPE)

Print:

• GENERAL CABLE ® (PLANT OF MFG) CHTC XX/
PS/TS XXAWG CU/XLP/XL-CPE SHIELDED (UL)
TYPE PLTC 90˚C SUN RES OIL RES I & II PLUS
DAY/MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

Options:

• Bare copper conductor
• Class C stranding
• Individual and overall shielded pairs/triads
• Thermoplastic Low-Smoke, Zero-Halogen (LSZH)
jacket
• In accordance with UL Subject 2250 as
Instrumentation Tray Cable (ITC)
• Other constructions available upon request

Applications:
13
18
23
44
86
127
169
210
252
377
523

19
26
34
65
127
189
251
313
375
561
778

32
40
58
99
173
245
318
392
450
672
904

48
60
86
147
257
365
473
583
670
1000
1345

18
27
36
69
135
202
268
335
401
601
834

28
41
61
40
54
80
53
85
126
102 135 201
201 246 366
300 346 515
399 444 661
498 552 821
597 655 975
894 649 966
1241 1308 1947

OVERALL SHIELDED PAIRS/TRIADS
16 AWG CONDUCTORS
1
309520*
337930* 1 TRI
2
337940*
4
337950*
8
337960*
12
337970*
16
337980*
20
337990*
24
338000*
36
338010*
338020* 50

Shield:

Jacket:

OVERALL SHIELDED PAIRS/TRIADS
20 AWG CONDUCTORS
337770*
337780*
337790*
309660*
309670*
309680*
337800*
337810*
309690*
311640*
309700*

• Flame-retardant Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black
and white; Triads - black, white and red. One
conductor in each pair or triad is printed alphanumerically for easy identification

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

• Typical applications include audio, intercom,
control, energy management and alarm circuits
• In free air or raceways in accordance with NEC
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC
• In ducts, cable trays or conduit
• In accordance with UL Subject 13 as PowerLimited Circuit Cable
• In class 3 circuits in accordance with NEC

Features:

• Rated at 90˚C
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Oil-resistant jacket
• Sunlight- and weather-resistant
• Excellent electrical, thermal and physical
properties
• Excellent moisture resistance
• Excellent flame resistance
• “Heavy duty” rating per ICEA standards
• Excellent low temperature cold bend
characteristics
• Meets cold bend test at -35˚C

Compliances:

Industry Compliances:
	 • UL 13 Type PLTC, UL File # E36118
	 • UL 1581
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 1100
March, 2012

CHTC

®

XLPE/XL-CPE, Instrumentation, Shielded
300 V, UL Type PLTC, Individual and Overall Shielded Pairs
Product Construction:
Conductor:

•	20 AWG thru 16 AWG tinned, annealed copper per
ASTM B33
•	Class B stranding per ASTM B8

Insulation:

•	Flame-retardant Cross-linked Polyethylene (XLPE)
•	Color-coded per ICEA Method 1: Pairs - black and
white. One conductor in each pair is printed alphanumerically for easy identification

Shield:

Individual and overall shielded pairs
•	Individual pairs are 100% shielded with Flexfoil®
aluminum/polyester in contact with stranded
tinned copper drain wire
•	Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

•	Lead-free Cross-linked Chlorinated Polyethylene
(XL-CPE)

Print:

•	GENERAL CABLE ® (PLANT OF MFG) CHTC XX/
SPS XX AWG CU/XLP/XL-CPE SHIELDED (UL)
TYPE PLTC 90˚C SUN RES OIL RES I & II DAY/
MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE
MARK

Options:

•	Bare copper conductor
•	Class C stranding
•	Overall shielded pairs
•	Thermoplastic Low-Smoke, Zero-Halogen (LSZH)
jacket
•	In accordance with UL Subject 2250 as
Instrumentation Tray Cable (ITC)
•	Other constructions available upon request

Applications:

•	Typical applications include audio, intercom,
control, energy management and alarm circuits
•	In free air or raceways in accordance with NEC
•	Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC
•	In ducts, cable trays or conduit
•	In accordance with UL Subject 13 as PowerLimited Circuit Cable
•	In class 3 circuits in accordance with NEC

Features:

•	Rated at 90˚C
•	Ripcord applied to all cables with jacket thickness
of 60 mils or less
•	Oil-resistant jacket
•	Sunlight- and weather-resistant
•	Excellent electrical, thermal and physical
properties
•	Excellent moisture resistance
•	Excellent flame resistance
•	“Heavy duty” rating per ICEA standards
•	Excellent low temperature cold bend
characteristics
•	Meets cold bend test at -35˚C

Compliances:

Industry Compliances:
	 • UL 13 Type PLTC, UL File # E36118
	 • UL 1581
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
COND.
THICKNESS
THICKNESS
CABLE
O.D.
NO. OF SIZE COND.
LBS/
LBS/
PAIRS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

INDIVIDUAL AND OVERALL SHIELDED PAIRS
20 AWG CONDUCTORS
338030*
309540*
309550*
309560*
338040*
338050*
309570*
309580*
338060*

2
4
8
12
16
20
24
36
50

20
20
20
20
20
20
20
20
20

7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121

0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012

0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30

0.040
0.050
0.050
0.060
0.060
0.060
0.070
0.070
0.070

1.02
1.27
1.27
1.52
1.52
1.52
1.78
1.78
1.78

0.340
0.415
0.525
0.645
0.715
0.785
0.875
1.045
1.215

8.64
10.54
13.34
16.38
18.16
19.94
22.23
26.54
30.86

21
40
78
117
155
193
231
346
479

31
60
116
147
231
287
344
515
713

54
93
157
233
294
357
422
620
828

80
138
234
347
438
531
628
923
1232

41
79
155
231
307
378
459
687
952

76
113
203
300
383
483
571
816
1119

113
168
302
446
570
719
850
1214
1665

INDIVIDUAL AND OVERALL SHIELDED PAIRS
18 AWG CONDUCTORS
338070*
338080*
338090*
338100*
338110*
338120*
338130*
338140*
338150*

2
4
8
12
16
20
24
36
50

18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.050
0.050
0.060
0.060
0.060
0.070
0.070
0.070
0.080

1.27
1.27
1.52
1.52
1.52
1.78
1.758
1.78
2.03

0.415
0.475
0.605
0.750
0.830
0.945
1.045
1.225
1.450

10.54
12.07
15.37
19.05
21.08
24.00
26.54
31.12
36.83

28
53
104
155
206
254
308
461
640

INDIVIDUAL AND OVERALL SHIELDED PAIRS
16 AWG CONDUCTORS
338160*
338170*
338180*
338190*
338200*
338210*
338220*
338230*
338240*

2
4
8
12
16
20
24
36
50

16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.050
0.050
0.060
0.060
0.070
0.070
0.070
0.080
0.080

1.27
1.27
1.52
1.52
1.78
1.78
1.78
2.03
2.03

0.440
0.545
0.965
0.885
0.980
1.080
1.235
1.405
1.640

11.18
13.84
24.51
22.48
24.89
27.43
31.37
35.69
41.66

40
78
153
229
304
380
455
662
945

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

60
92
137
116
163 243
228 287 427
341 437 650
453 553 823
566 680 1012
677 800 1191
985 1108 1649
1408 1523 2267

SPEC 1150
March, 2012

CVTC

®

XLPE/PVC, Instrumentation, Shielded
300 V, UL Type PLTC, Overall Shielded Pairs/Triads
Product Construction:
Conductor:

• 18 AWG and 16 AWG bare, annealed
copper per ASTM B3
• Class B stranding per ASTM B8

Insulation:

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. OF COND.
THICKNESS
THICKNESS
CABLE
O.D.
PAIRS/ SIZE COND.
LBS/
LBS/
TRIADS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

OVERALL SHIELDED PAIRS/TRIADS
18 AWG CONDUCTORS
366140*
342930*
342940*
342950*
342960*
342970*
342980*
342990*
343000*
343010*
343020*

1
1 TRI
2
4
8
12
16
20
24
36
50

18
18
18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.035
0.040
0.040
0.050
0.050
0.060
0.060
0.060
0.060
0.070
0.070

0.89
1.02
1.02
1.27
1.27
1.52
1.52
1.52
1.52
1.78
1.78

0.235
0.250
0.365
0.440
0.550
0.675
0.750
0.785
0.905
1.080
1.245

5.97
6.35
9.27
11.18
13.97
17.15
19.05
19.94
22.99
27.43
31.62

1
1 TRI
2
4
8
12
16
20
24
36
50

16
16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.035
0.040
0.050
0.050
0.060
0.060
0.060
0.070
0.070
0.070
0.080

0.89
1.02
1.27
1.27
1.52
1.52
1.52
1.78
1.78
1.78
2.03

0.262
0.280
0.430
0.490
0.650
0.755
0.845
0.880
1.020
1.220
1.405

6.65
7.11
10.92
12.45
16.51
19.18
21.46
22.35
25.91
30.99
35.69

Shield:

Overall shielded pairs/triads
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:
13
18
25
46
87
129
171
211
253
377
524

19
27
37
68
129
192
254
314
377
561
780

32
40
56
98
175
250
317
392
476
681
913

48
60
83
146
260
372
472
583
708
1013
1359

OVERALL SHIELDED PAIRS/TRIADS
16 AWG CONDUCTORS
366150*
343030*
343040*
343050*
343060*
343070*
343080*
343090*
343100*
343110*
343120*

• Flame-retardant Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black
and white; Triads - black, white and red. One
conductor in each pair or triad is printed alphanumerically for easy identification

• Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Print:

• GENERAL CABLE ® (PLANT OF MFG) CVTC XX/
PS/TS XXAWG FR-XLP/PVC SHIELDED (UL) TYPE
PLTC 90˚C SUN RES PLUS DAY/MONTH/YEAR
OF MFG SEQUENTIAL FOOTAGE MARK

Options:

• Tinned copper conductor
• Class C stranding
• Individual and overall shielded pairs/triads
• Ethylene Propylene Rubber (EPR) insulation
• In accordance with UL Subject 2250 as
Instrumentation Tray Cable (ITC)
• Other constructions available upon request

Applications:
19
27
37
71
135
203
270
334
400
599
831

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

28
42
63
40
53
79
55
81
121
106 131 195
201 254 378
302 350 521
402 451 671
497 545 811
595 657 978
891 965 1423
1237 1322 1967

• In free air and raceways in accordance with NEC
• Typical applications include audio, intercom,
control, energy management and alarm circuits
• In ducts, cable trays or conduit
• In accordance with UL Subject 13 as PowerLimited Circuit Cable
• In Class 3 circuits in accordance with NEC
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

Features:

• Rated at 90˚C
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Abrasion- and chemical-resistant
• Excellent electrical properties
• Sunlight- and weather-resistant
• Meets cold bend test at -25˚C

Compliances:

Industry Compliances:
	 • UL 13 Type PLTC, UL File # E36118
	 • UL 1581
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • IEEE 383
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 1200

March, 2012

CVTC

®

XLPE/PVC, Instrumentation, Shielded
300 V, UL Type PLTC, Individual and Overall Shielded Pairs
Product Construction:
Conductor:

• 18 AWG and 16 AWG bare, annealed copper per
ASTM B3
• Class B stranding per ASTM B8

Insulation:

• Flame-retardant Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black and
white. One conductor in each pair is printed alphanumerically for easy identification

Shield:

Individual and overall shielded pairs
• Individual pairs are 100% shielded with Flexfoil®
aluminum/polyester in contact with stranded
tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Print:

• GENERAL CABLE ® (PLANT OF MFG) CVTC XX/
SPS XXAWG FR-XLP/PVC SHIELDED (UL) TYPE
PLTC 90˚C SUN RES PLUS DAY/MONTH/YEAR
OF MFG SEQUENTIAL FOOTAGE MARK

Options:

• Tinned copper conductor
• Class C stranding
• Overall shielded pairs
• Ethylene Propylene Rubber (EPR) insulation
• In accordance with UL Subject 2250 as
Instrumentation Tray Cable (ITC)
• Other constructions available upon request

Applications:

• In free air and raceways in accordance with NEC
• Typical applications include audio, intercom,
control, energy management and alarm circuits
• In ducts, cable trays or conduit
• In accordance with UL Subject 13 as PowerLimited Circuit Cable
• In Class 3 circuits in accordance with NEC
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

Features:

• Rated at 90˚C
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Abrasion- and chemical-resistant
• Excellent electrical properties
• Sunlight- and weather-resistant
• Meets cold bend test at -25˚C

Compliances:

Industry Compliances:
	 • UL 13 Type PLTC, UL File # E36118
	 • UL 1581
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • IEEE 383
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
COND.
THICKNESS
THICKNESS
CABLE
O.D.
NO. OF SIZE COND.
LBS/
LBS/
PAIRS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

INDIVIDUAL AND OVERALL SHIELDED PAIRS
18 AWG CONDUCTORS
343140*
343150*
343160*
343170*
343180*
343190*
343200*
343210*
343220*

2
4
8
12
16
20
24
36
50

18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.050
0.050
0.050
0.060
0.060
0.070
0.070
0.070
0.080

1.27
1.27
1.27
1.52
1.52
1.78
1.78
1.78
2.03

0.410
0.475
0.605
0.750
0.830
0.955
1.030
1.210
1.425

10.41
12.07
15.37
19.05
21.08
24.26
26.16
30.73
36.20

30
55
105
156
207
252
302
452
637

45
82
156
232
308
375
449
673
948

73
109
117
174
215 320
308 458
392 583
494 735
583 868
830 1235
1145 1704

INDIVIDUAL AND OVERALL SHIELDED PAIRS
16 AWG CONDUCTORS
343240*
343250*
343260*
343270*
343280*
343290*
343300*
343310*
343320*

2
4
8
12
16
20
24
36
50

16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.050
0.050
0.060
0.060
0.070
0.070
0.070
0.080
0.080

1.27
1.27
1.52
1.52
1.78
1.78
1.78
2.03
2.03

0.455
0.530
0.710
0.855
0.955
1.055
1.160
1.380
1.580

11.56
13.46
18.03
21.72
24.26
26.80
29.46
35.05
40.13

42
80
155
230
306
375
456
674
945

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

63
96
143
119 160 238
231 293 436
342 425 632
455 563 838
558 664 988
679 780 1161
1003 1137 1692
1406 1518 2259

SPEC 1250

March, 2012

PVIC

®

PVC/PVC, Instrumentation, Shielded
300 V, UL Type PLTC/ITC, Overall Shielded Pairs/Triads
Product Construction:
Conductor:

• 20 AWG thru 16 AWG bare, annealed
copper per ASTM B3
• Class B stranding per ASTM B8

Insulation:

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. OF COND.
THICKNESS
THICKNESS
CABLE
O.D.
PAIRS/ SIZE COND.
LBS/
LBS/
TRIADS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

OVERALL SHIELDED PAIRS/TRIADS
20 AWG CONDUCTORS
325900
325910
325920
325940
339620*
348090*
334630*
348100*
759610*
339650*
339660*

1
1 TRI
2
4
8
12
16
20
24
36
50

20
20
20
20
20
20
20
20
20
20
20

7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121

0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012

0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30

0.040
0.040
0.040
0.042
0.050
0.050
0.050
0.060
0.060
0.060
0.070

1.02
1.02
1.02
1.07
1.27
1.27
1.27
1.52
1.52
1.52
1.78

0.220
0.241
0.255
0.321
0.475
0.545
0.605
0.650
0.740
0.850
0.970

5.59
6.12
6.48
8.15
12.07
13.84
15.37
16.51
18.80
21.59
24.64

18
18
18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.040
0.040
0.042
0.042
0.060
0.060
0.060
0.060
0.070
0.070
0.070

1.02
1.02
1.07
1.07
1.52
1.52
1.52
1.52
1.78
1.78
1.78

0.240
0.264
0.325
0.357
0.646
0.670
0.750
0.780
0.915
1.030
1.180

6.10
6.71
8.26
9.07
16.41
17.02
19.05
19.81
23.24
26.16
29.97

13
18
25
45
80
124
159
201
228
354
491

28
34
41
65
104
195
248
309
376
530
713

42
51
60
97
154
290
369
460
559
789
1061

12
18
25
46
87
129
171
211
253
453
524

18
27
37
68
129
192
254
314
377
674
780

35
52
44
66
55
82
90
133
192 285
293 436
374 556
449 668
564 839
787 1171
1059 1576

18
27
37
71
135
203
270
334
400
599
831

27
45
67
40
58
86
55
74
109
106 132 197
201 259 385
302 408 607
402 526 783
497 655 975
595 803 1195
891 1122 1670
1237 1544 2298

OVERALL SHIELDED PAIRS/TRIADS
16 AWG CONDUCTORS
1
325770
325780 1 TRI
2
325790
4
325810
8
339700*
298830* 12
760530* 16
20
339710*
339720* 24
339730* 36
50
339740*

16
16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.040
0.042
0.042
0.053
0.060
0.060
0.070
0.070
0.070
0.070
0.080

1.02
1.07
1.07
1.35
1.52
1.52
1.78
1.78
1.78
1.78
2.03

0.273
0.297
0.344
0.481
0.726
0.755
0.845
0.905
1.030
1.165
1.355

6.93
7.54
8.74
12.22
18.44
19.18
21.46
22.99
26.16
29.59
34.42

Shield:

Overall shielded pairs/triads
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:
9
12
17
30
54
83
107
135
153
238
330

OVERALL SHIELDED PAIRS/TRIADS
18 AWG CONDUCTORS
1
325830
325840 1 TRI
2
325850
4
325880
8
348020*
348030* 12
348040* 16
339670* 20
339680* 24
36
791720*
339690* 50

• Lead-free Polyvinyl Chloride (PVC)
• Color-coded per ICEA Method 1: Pairs - black
and white; Triads - black, white and red. One
conductor in each pair or triad is printed alphanumerically for easy identification

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

• Lead-free, sunlight-resistant Polyvinyl Chloride
(PVC)

Print:

• GENERAL CABLE ® (PLANT OF MFG) PVIC® XX/
PS/TS XXAWG PVC/PVC SHIELDED (UL) TYPE
PLTC OR ITC 105˚C SUN RES MONTH/YEAR OF
MFG SEQUENTIAL FOOTAGE MARK

Options:

• Tinned copper conductor
• Class C stranding
• Other constructions available upon request

Applications:

• In free air and raceways in accordance with NEC
• Typical applications include audio, intercom,
control, energy management and alarm
circuits
• In ducts, cable trays or conduit
• In accordance with UL Subject 13 as PowerLimited Circuit Cable
• In Class 3 circuits in accordance with NEC
Article 725
• In accordance with UL Subject 2250 as
Instrumentation Tray Cable (ITC)
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC Article
501.10(B)(4) for UL Type PLTC/ITC cables
• Per NEC Article 727 for Type PLTC/ITC

Features:

• Rated at 105˚C
• Good electrical properties
• Oil- and sunlight-resistant
• Flame-retardant
• Good mechanical properties
• Meets cold bend test at -25˚C

Compliances:

Industry Compliances:
	 • UL Type PLTC/ITC, UL File # E36118
	 • RoHS Compliant
Flame Test Compliances:
	 • IEEE 383 (70,000 BTU/hr)
	 • UL Subject 13 (70,000 BTU/hr) for PLTC
	 • UL Subject 2250 (70,000 BTU/hr) for ITC
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 1300

March, 2012

PVIC

®

PVC/PVC, Instrumentation, Shielded
300 V, UL Type PLTC/ITC, Individual and Overall Shielded Pairs
Product Construction:
Conductor:

• 20 AWG thru 16 AWG bare, annealed
copper per ASTM B3
• Class B stranding per ASTM B8

Insulation:

• Lead-free Polyvinyl Chloride (PVC)
• Color-coded per ICEA Method 1: Pairs - black and
white. One conductor in each pair is printed alphanumerically for easy identification

Shield:

Individual and overall shielded pairs
• Individual pairs are 100% shielded with Flexfoil®
aluminum/polyester in contact with stranded
tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, sunlight-resistant Polyvinyl Chloride
(PVC)

Print:

• GENERAL CABLE ® (PLANT OF MFG) PVIC XX/
SPS XXAWG PVC/PVC SHIELDED (UL) TYPE
PLTC OR ITC 105˚C SUN RES MONTH/YEAR OF
MFG SEQUENTIAL FOOTAGE MARK

Options:

• Tinned copper conductor
• Class C stranding
• Other constructions available upon request

Applications:

• In free air and raceways in accordance with NEC
• Typical applications include audio, intercom,
control, energy management and alarm circuits
• In ducts, cable trays or conduit
• In accordance with UL Subject 13 as PowerLimited Circuit Cable
• In Class 3 circuits in accordance with NEC
Article 725
• In accordance with UL Subject 2250 as
Instrumentation Tray Cable (ITC)
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC Article
501.10(B)(4) for UL Type PLTC/ITC cables
• Per NEC Article 727 for Type PLTC/ITC

Features:

• Rated at 105˚C
• Good electrical properties
• Oil- and sunlight-resistant
• Flame-retardant
• Good mechanical properties
• Meets cold bend test at -25˚C

Compliances:

Industry Compliances:
	 • UL Type PLTC/ITC, UL File # E36118
	 • RoHS Compliant
Flame Test Compliances:
	 • IEEE 383 (70,000 BTU/hr)
	 • UL Subject 13 (70,000 BTU/hr) for PLTC
	 • UL Subject 2250 (70,000 BTU/hr) for ITC
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
COND.
THICKNESS
THICKNESS
CABLE
O.D.
NO. OF SIZE COND.
LBS/
LBS/
PAIRS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

INDIVIDUAL AND OVERALL SHIELDED PAIRS
20 AWG CONDUCTORS
325930
325950
339750
339760*
348110*
339770*
339780*
348120*
341790*

2
4
8
12
16
20
24
36
50

20
20
20
20
20
20
20
20
20

7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121

0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012

0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30

0.040
0.042
0.050
0.060
0.060
0.060
0.060
0.070
0.070

1.02
1.07
1.27
1.52
1.52
1.52
1.52
1.78
1.78

0.316
0.325
0.426
0.640
0.705
0.780
0.845
1.015
1.190

8.03
8.26
10.82
16.26
17.91
19.81
21.46
25.78
30.23

22
39
71
83
165
175
209
324
433

33
58
106
124
246
260
311
482
644

46
76
148
223
280
339
397
586
786

69
113
220
332
417
504
591
872
1170

45
82
156
232
308
375
449
673
935

61
91
100 149
212 316
315 469
401 597
505 752
596 887
846 1259
1165 1734

INDIVIDUAL AND OVERALL SHIELDED PAIRS
18 AWG CONDUCTORS
325860
325890
348060
348070*
760420*
339800*
339810*
339820*
339830*

2
4
8
12
16
20
24
36
50

18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.042
0.042
0.060
0.060
0.060
0.070
0.070
0.070
0.080

1.07
1.07
1.52
1.52
1.52
1.78
1.78
1.78
2.03

0.380
0.410
0.485
0.760
0.845
0.955
1.040
1.215
1.450

9.65
10.41
12.32
19.30
21.46
24.26
26.42
30.86
36.83

30
55
105
156
207
252
302
452
628

INDIVIDUAL AND OVERALL SHIELDED PAIRS
16 AWG CONDUCTORS
325800
325820
298880
298890
759770*
339840*
759780*
339850*
339860*

2
4
8
12
16
20
24
36
50

16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.042
0.053
0.060
0.060
0.070
0.070
0.070
0.080
0.090

1.07
1.35
1.52
1.52
1.78
1.78
1.78
2.03
2.29

0.346
0.506
0.665
0.855
0.970
1.080
1.165
1.390
1.655

8.79
12.85
16.89
21.72
24.64
27.43
29.59
35.31
42.04

42
80
155
230
306
375
456
674
935

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

63
80
119
119 151 225
231 288 429
342 435 647
455 575 856
558 705 1049
679 828 1232
1003 1215 1808
1391 1670 2485

SPEC 1350

March, 2012

PVIC

®

PVC/PVC, Instrumentation, Shielded
300 V, UL Type PLTC/ITC, Individual and Overall Shielded Triads
Product Construction:
Conductor:

• 20 AWG thru 16 AWG bare, annealed
copper per ASTM B3
• Class B stranding per ASTM B8

Insulation:

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
COND.
THICKNESS
THICKNESS
CABLE
O.D.
NO. OF SIZE COND.
LBS/
LBS/
TRIADS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

INDIVIDUAL AND OVERALL SHIELDED TRIADS
20 AWG CONDUCTORS
339870*
339880*
339890*
339900*
339910*
339920*
339930*
339940*

2 TRI
4 TRI
8 TRI
12 TRI
16 TRI
20 TRI
24 TRI
36 TRI

20
20
20
20
20
20
20
20

7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121

0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012

0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30

0.040
0.040
0.050
0.060
0.060
0.060
0.070
0.070

1.07
1.07
1.27
1.52
1.52
1.52
1.78
1.78

0.340
0.365
0.566
0.705
0.780
0.860
0.955
1.115

8.64
9.27
14.38
17.91
19.81
21.84
24.26
28.32

26
48
97
145
192
240
288
431

39
71
144
216
286
357
429
641

59
97
187
287
365
440
541
767

88
144
279
427
543
655
805
1141

57
109
219
320
426
531
637
954

77
115
143 213
275 409
412 613
550 819
668 994
785 1168
1151 1713

INDIVIDUAL AND OVERALL SHIELDED TRIADS
18 AWG CONDUCTORS
325870*
339960*
348010*
760300*
339980*
339990*
340000*
340010*

2 TRI
4 TRI
8 TRI
12 TRI
16 TRI
20 TRI
24 TRI
36 TRI

18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.040
0.050
0.060
0.060
0.070
0.070
0.070
0.080

1.07
1.27
1.52
1.52
1.78
1.78
1.78
2.03

0.321
0.444
0.691
0.840
0.960
1.060
1.145
1.365

8.15
11.28
17.55
21.34
24.38
26.92
29.08
34.67

38
73
147
215
286
357
428
641

INDIVIDUAL AND OVERALL SHIELDED TRIADS
16 AWG CONDUCTORS
340020*
340030*
340040*
340050*
340060*
340070*
340080*
340090*

2 TRI
4 TRI
8 TRI
12 TRI
16 TRI
20 TRI
24 TRI
36 TRI

16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.040
0.050
0.060
0.070
0.070
0.070
0.080
0.080

1.07
1.27
1.52
1.78
1.78
1.78
2.03
2.03

0.367
0.502
0.786
0.970
1.075
1.195
1.310
1.540

9.32
12.75
19.96
24.64
27.31
30.35
33.27
40.39

54
108
218
325
433
541
649
972

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

80
104 154
161 195 290
324 375 558
484 597 888
644 765 1138
805 933 1388
966 1125 1674
1447 1620 2411

• Lead-free Polyvinyl Chloride (PVC)
• Color-coded per ICEA Method 1: Triads - black,
white and red. One conductor in each triad is
printed alpha-numerically for easy identification

Shield:

Individual and overall shielded triads
• Individual triads are 100% shielded with Flexfoil®
aluminum/polyester in contact with stranded
tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, sunlight-resistant Polyvinyl Chloride
(PVC)

Print:

• GENERAL CABLE ® (PLANT OF MFG) PVIC XX/
STS XXAWG PVC/PVC SHIELDED (UL) TYPE
PLTC OR ITC 105˚C SUN RES MONTH/YEAR OF
MFG SEQUENTIAL FOOTAGE MARK

Options:

• Tinned copper conductor
• Class C stranding
• Other constructions available upon request

Applications:

• In free air and raceways in accordance with NEC
• Typical applications include audio, intercom,
control, energy management and alarm circuits
• In ducts, cable trays or conduit
• In accordance with UL Subject 13 as PowerLimited Circuit Cable
• In Class 3 circuits in accordance with NEC
Article 725
• In accordance with UL Subject 2250 as
Instrumentation Tray Cable (ITC)
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC Article
501-4(b) for UL Type PLTC/ITC cables
• Per NEC Article 727 for Type PLTC/ITC

Features:

• Rated at 105˚C
• Good electrical properties
• Oil and sunlight resistance
• Flame-retardant
• Good mechanical properties
• Meets cold bend test at -25˚C

Compliances:

Industry Compliances:
	 • UL Type PLTC/ITC, UL File # E36118
	 • RoHS Compliant
Flame Test Compliances:
	 • IEEE 383 (70,000 BTU/hr)
	 • UL Subject 13 (70,000 BTU/hr) for PLTC
	 • UL Subject 2250 (70,000 BTU/hr) for ITC
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

Date of Issue 06/13
Section 2		

Industrial Cables

600 V Instrumentation Cables
SPECIFICATION NO.

PRODUCT DESCRIPTION

REVISION DATE

2050†

CHTC®

XLPE/XL-CPE, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Pairs/Triads

Mar. 2012

2100†

FREP®

FR-EPR/CPE, Instrumentation, Shielded
600 V, UL Type TC, Overall Shielded Pairs/Triads

Mar. 2012

2150†

FREP®

FR-EPR/CPE, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Pairs

Mar. 2012

2200

FREP®

FR-EPR/CPE, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Triads

Mar. 2012

2250

Arctic-Flex® XLPE/ARCTIC-PVC, Instrumentation, Shielded
600 V, UL Type TC, CSA Type CIC, Overall Shielded Pairs/Triads

Mar. 2012

2300

Arctic-Flex® XLPE/ARCTIC-PVC, Instrumentation, Shielded
600 V, UL Type TC, CSA Type CIC, Individual and Overall Shielded Pairs

Mar. 2012

2350

CVTC®

XLPE/PVC, Instrumentation, Shielded
600 V, UL Type TC, Overall Shielded Pairs/Triads

Mar. 2012

2400

CVTC®

XLPE/PVC, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Pairs

Mar. 2012

2450†

VNTC®

PVC/Nylon/PVC, Instrumentation, Shielded
600 V, UL Type TC, Overall Shielded Pairs/Triads

Mar. 2012

2500†

VNTC®

PVC/Nylon/PVC, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Pairs

Mar. 2012

2600†

GenFree®

XLPE/LSZH, Instrumentation, Shielded
600 V, UL Type TC-LS, Overall Shielded Pairs/Triads

Mar. 2012

2625†

GenFree®

XLPE/LSZH, Instrumentation, Shielded
600 V, UL Type TC-LS, Individual and Overall Shielded Pairs

Mar. 2012

2650

GenFree®

XLPE/LSZH, Instrumentation, Shielded
600 V, UL Type TC-LS, Individual and Overall Shielded Triads

Mar. 2012

†Indicates

these products are stocked by General Cable

Phone: 888-593-3355
www.generalcable.com

SPEC 2050
March, 2012

CHTC

®

XLPE/XL-CPE, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Pairs/Triads
Product Construction:
Conductor:

• 18 AWG and 16 AWG tinned, annealed
copper per ASTM B33
• Class B stranding per ASTM B8

Insulation:

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. OF COND.
THICKNESS
THICKNESS
CABLE
O.D.
PAIRS/ SIZE COND.
LBS/
LBS/
TRIADS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

INDIVIDUAL AND OVERALL SHIELDED PAIRS/TRIADS
18 AWG CONDUCTORS
1
18 7/.0152 0.030 0.76 0.045 1.52 0.315 8.15
13
19
49
73
285150
26
64
95
337620* 1 TRI 18 7/.0152 0.030 0.76 0.045 1.14 0.335 8.51 18
2
18 7/.0152 0.030 0.76 0.045 1.14 0.510 12.95
28
42
92
137
337630*
4
18 7/.0152 0.030 0.76 0.060 1.52 0.630 16.00
53
79
167 249
337640*
8
18 7/.0152 0.030 0.76 0.080 2.03 0.855 21.72 104 155
326 485
337650*
18 7/.0152 0.030 0.76 0.080 2.03 1.030 26.16 155 231
441 656
337660* 12
16
18 7/.0152 0.030 0.76 0.080 2.03 1.140 28.96 206 307
554 824
337670*
18 7/.0152 0.030 0.76 0.080 2.03 1.265 32.13 256 381
676 1006
337680* 20
18 7/.0152 0.030 0.76 0.080 2.03 1.450 36.83 308 459
795 1183
337690* 24
18 7/.0152 0.030 0.76 0.110 2.79 1.650 41.91 461 687 1118 1664
337700* 36
50
18 7/.0152 0.030 0.76 0.110 2.79 2.085 52.96 637 948 1616 2405
337710*
INDIVIDUAL AND OVERALL SHIELDED PAIRS/TRIADS
16 AWG CONDUCTORS
1
16 7/.0192 0.030 0.76 0.045 1.52 0.345 8.76
19
28
61
91
240990
42
85
127
241510 1 TRI 16 7/.0192 0.030 0.76 0.045 1.52 0.360 9.10 28
2
16 7/.0192 0.030 0.76 0.060 1.52 0.585 14.86
40
60
130 193
241010
4
16 7/.0192 0.030 0.76 0.060 1.52 0.675 17.15
78 116
204 304
232560
8
16 7/.0192 0.030 0.76 0.080 2.03 0.915 23.24 153 228
394 586
241000*
12
16 7/.0192 0.030 0.76 0.080 2.03 1.110 28.19 229 341
548
816
252370
16 7/.0192 0.030 0.76 0.080 2.03 1.350 34.29 304 453
713 1061
337720* 16
16 7/.0192 0.030 0.76 0.080 2.03 1.365 34.67 380 566
850 1265
337730* 20
24
16 7/.0192 0.030 0.76 0.080 2.03 1.570 39.88 455 677 1001 1490
337740*
16 7/.0192 0.030 0.76 0.110 2.79 1.980 50.29 682 1014 1548 2304
337750* 36
16 7/.0192 0.030 0.76 0.110 2.79 2.165 54.99 946 1408 2020 3006
337760* 50
Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

• Flame-retardant Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black
and white; Triads - black, white and red. One
conductor in each pair or triad is printed alphanumerically for easy identification

Shield:

Individual and overall shielded pairs/triads
• Individual pairs/triads are 100% shielded with
Flexfoil® aluminum/polyester in contact with
stranded tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free Cross-linked Chlorinated Polyethylene
(XL-CPE)

Print:

• GENERAL CABLE ® (PLANT OF MFG) CHTC®
XX/SPS/STS XXAWG SHIELDED CU/XLP/XL-CPE
SHIELDED (UL) TYPE TC 600 V 90˚C WET OR
DRY SUN RES OIL RES I & II DAY/MONTH/YEAR
OF MFG SEQUENTIAL FOOTAGE MARK

Options:

• 300 V Type PLTC
• Bare copper conductor
• Class C stranding
• Overall shielded pairs/triads
• EHTC®—Ethylene Propylene Rubber (EPR)
insulation
• Thermoplastic Low-Smoke, Zero-Halogen (LSZH)
jacket
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2
industrial hazardous locations per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Oil-resistant jacket
• Sunlight- and weather-resistant
• Excellent electrical, thermal and physical
properties
• Excellent moisture resistance
• Excellent flame resistance
• “Heavy duty” rating per ICEA standards
• Excellent low temperature cold bend
characteristics
• Meets cold bend test at -35˚C

Compliances:

Industry Compliances:
	 • UL Type RFH-2, FFH-2 conductors
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 2100

March, 2012

FREP

®

FR-EPR/CPE, Instrumentation, Shielded
600 V, UL Type TC, Overall Shielded Pairs/Triads
Product Construction:
Conductor:

• 18 AWG and 16 AWG tinned, annealed copper per
ASTM B33
• Class B stranding per ASTM B8

Insulation:

• Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II
• Color-coded per ICEA Method 1: Pairs - black
and white; Triads - black, white and red. One
conductor in each pair or triad is printed alphanumerically for easy identification

Shield:

Overall shielded pairs/triads
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. OF COND.
THICKNESS
THICKNESS
CABLE
O.D.
PAIRS/ SIZE COND.
LBS/
LBS/
TRIADS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

OVERALL SHIELDED PAIRS/TRIADS
18 AWG CONDUCTORS

Jacket:

• Lead-free, flame-retardant, thermoplastic
Chlorinated Polyethylene (CPE)

Print:

• GENERAL CABLE ® (PLANT OF MFG) FREP®
XX/PS/TS XXAWG EPR/CPE SHIELDED
(UL) TYPE TC 90˚C WET OR DRY 600 V DIR
BUR SUN RES DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

Options:

• Bare copper conductor
• Class C stranding
• Individual and overall shielded pairs/triads
• CCTC—Cross-linked Polyethylene (XLPE)
insulation
• FREP ® XL-flame-retardant, thermoset Chlorinated
Polyethylene (XL-CPE) jacket
• FREP ® II-flame-retardant, thermoplastic LowSmoke, Zero-Halogen (LSZH) Polyolefin jacket
• FREP ® 300 V-UL Type PLTC
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties
• Excellent moisture resistance
• Excellent resistance to compression cuts and heat
deformation
• Excellent flame resistance—burns to an ash; does
not exhibit thermoplastic drip
• Low coefficient of friction for easy pulling
• Sunlight- and weather-resistant
• Excellent low temperature cold bend
characteristics
• Meets cold bend test at -40˚C

Compliances:

Industry Compliances:
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

1
287650*
325250* 1 TRI
2
337010*
4
337020*
8
337030*
337040* 12
294580* 16
337050* 20
337060* 24
36
337070*
337080* 50

18
18
18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025

0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64

0.045
0.045
0.045
0.045
0.060
0.060
0.080
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.52
1.52
2.03
2.03
2.03
2.03
2.03

0.300
0.315
0.420
0.490
0.675
0.775
0.925
1.025
1.105
1.360
1.555

7.62
8.00
10.67
12.45
17.15
19.69
23.50
26.04
28.07
34.54
39.50

13
18
23
44
86
127
169
210
252
377
523

19
26
34
65
127
189
251
313
375
561
778

42
53
75
117
224
305
425
510
604
865
1144

63
79
112
174
333
454
632
759
899
1287
1703

OVERALL SHIELDED PAIRS/TRIADS
16 AWG CONDUCTORS
1
314960
279690 1 TRI
2
283170*
4
283180*
8
337090*
12
283190*
16
337100*
20
337110*
24
337120*
36
337130*
50
337140*

16
16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025

0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64

0.045
0.045
0.045
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03

0.320
0.335
0.460
0.560
0.740
0.900
1.015
1.130
1.215
1.505
2.095

8.13
8.51
11.68
14.22
18.80
22.86
25.78
28.70
30.86
38.23
53.21

18
28
26
39
36
54
69 103
135 201
202 300
268 399
335 498
401 597
601 894
834 1241

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

52
77
66
98
95
141
171 254
294 438
438 652
560 833
680 1012
807 1201
1160 1726
1702 2533

SPEC 2150

March, 2012

FREP

®

FR-EPR/CPE, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Pairs
Product Construction:
Conductor:

• 18 AWG and 16 AWG tinned, annealed copper per
ASTM B33
• Class B stranding per ASTM B8

Insulation:

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
COND.
THICKNESS
THICKNESS
CABLE
O.D.
NO. OF SIZE COND.
LBS/
LBS/
PAIRS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

INDIVIDUAL AND OVERALL SHIELDED PAIRS
18 AWG CONDUCTORS
279700
279710
279720*
279730*
279740*
319270*
279750*
337240*
337250*

2
4
8
12
16
20
24
36
50

18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025

0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64

0.045
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.110

1.14
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.79

0.473
0.586
0.751
0.948
1.050
1.185
1.220
1.474
1.780

12.01
14.88
19.08
24.08
26.67
30.10
30.99
37.44
45.21

27
53
103
153
206
254
311
461
640

41
83
124
78 152 226
153 259 385
228 398 592
307 502
747
378 623 927
463 709 1055
687 1008 1500
952 1454 2164

INDIVIDUAL AND OVERALL SHIELDED PAIRS
16 AWG CONDUCTORS
280500
280520
280530
280540
279760
280990*
337260*
279770*
288260*
288250*

2
4
6
8
12
16
20
24
36
50

16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025

0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64

0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.110

1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.79

0.500
0.650
0.755
0.840
1.065
1.185
1.320
1.485
1.760
2.035

12.70
16.51
19.18
21.34
27.05
30.10
33.53
37.72
44.70
51.69

40
77
115
151
226
305
380
455
683
946

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

59 103 153
114 189 281
171 268 399
225 330 491
337 506 753
453 643 957
566 777 1156
677 932 1387
1016 1410 2098
1408 1883 2802

• Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II
• Color-coded per ICEA Method 1: Pairs - black and
white. One conductor in each pair is printed alphanumerically for easy identification

Shield:

Individual and overall shielded pairs
• Individual pairs are 100% individually shielded
with Flexfoil® aluminum/polyester in contact with
stranded tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, flame-retardant, thermoplastic
Chlorinated Polyethylene (CPE)

Print:

• GENERAL CABLE ® (PLANT OF MFG) FREP ® XX/
SPS XXAWG EPR/CPE SHIELDED (UL) TYPE
TC 90˚C WET OR DRY 600 V DIR BUR SUN
RES DAY/MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

Options:

• Bare copper conductor
• Class C stranding
• Overall shielded pairs
• CCTC—Cross-linked Polyethylene (XLPE)
insulation
• FREP® XL-flame-retardant, thermoset Chlorinated
Polyethylene (XL-CPE) jacket
• FREP® II-flame-retardant, thermoplastic LowSmoke, Zero-Halogen (LSZH) Polyolefin jacket
• FREP® 300 V-UL Type PLTC
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties
• Excellent moisture resistance
• Excellent resistance to compression cuts and heat
deformation
• Excellent flame resistance—burns to an ash; does
not exhibit thermoplastic drip
• Low coefficient of friction for easy pulling
• Sunlight- and weather-resistant
• Excellent low temperature cold bend
characteristics
• Meets cold bend test at -40˚C

Compliances:

Industry Compliances:
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 2200
March, 2012

FREP

®

FR-EPR/CPE, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Triads
Product Construction:
Conductor:

• 18 AWG and 16 AWG tinned, annealed copper per
ASTM B33
• Class B stranding per ASTM B8

Insulation:

• Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II
• Color-coded per ICEA Method 1: Triads - black,
white and red. One conductor in each triad is
printed alpha-numerically for easy identification

Shield:

Individual and overall shielded triads
• Individual triads are 100% shielded with Flexfoil®
aluminum/polyester in contact with stranded
tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, flame-retardant, thermoplastic
Chlorinated Polyethylene (CPE)

Print:

• GENERAL CABLE ® (PLANT OF MFG) FREP ® XX/
STS XXAWG EPR/CPE SHIELDED (UL) TYPE
TC 90˚C WET OR DRY 600 V DIR BUR SUN
RES DAY/MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

Options:

• Bare copper conductor
• Class C stranding
• Overall shielded pairs/triads
• CCTC—Cross-linked Polyethylene (XLPE)
insulation
• FREP ® XL-flame-retardant, thermoset Chlorinated
Polyethylene (XL-CPE) jacket
• FREP ® II-flame-retardant, thermoplastic LowSmoke, Zero-Halogen (LSZH) polyolefin jacket
• FREP ® 300 V-UL Type PLTC
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties
• Excellent moisture resistance
• Excellent resistance to compression cuts and heat
deformation
• Excellent flame resistance—burns to an ash; does
not exhibit thermoplastic drip
• Low coefficient of friction for easy pulling
• Sunlight- and weather-resistant
• Excellent low temperature cold bend
characteristics
• Meets cold bend test at -40˚C

Compliances:

Industry Compliances:
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
COND.
THICKNESS
THICKNESS
CABLE
O.D.
NO. OF SIZE COND.
LBS/
LBS/
TRIADS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

INDIVIDUAL AND OVERALL SHIELDED TRIADS
18 AWG CONDUCTORS
337150*
319250*
319260*
337160*
294540*
337170*
337180*
337190*

2 TRI
4 TRI
8 TRI
12 TRI
16 TRI
20 TRI
24 TRI
36 TRI

18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025

0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64

0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080

1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03

0.560
0.640
0.825
1.065
1.180
1.310
1.500
1.740

14.22
16.26
20.96
27.05
29.97
33.27
38.10
44.20

38
73
144
218
290
361
433
649

57
109
214
324
431
538
645
965

127
201
343
528
675
825
972
1470

189
299
510
786
1005
1228
1447
2188

INDIVIDUAL AND OVERALL SHIELDED TRIADS
16 AWG CONDUCTORS
280950*
280960*
280970*
287410*
337200*
337210*
337220*
337230*

2 TRI
4 TRI
8 TRI
12 TRI
16 TRI
20 TRI
24 TRI
36 TRI

16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025

0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64

0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.110

1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.79

0.615
0.705
0.850
1.160
1.290
1.380
1.615
1.920

15.62
17.91
21.59
29.46
32.77
35.05
41.02
48.77

57
84 159 237
108 160 249 371
217 323 472 702
328 487 683 1016
436 649 879 1308
545 811 1058 1575
653 972 1266 1884
979 1457 1918 2854

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

SPEC 2250

March, 2012

Arctic-Flex

®

XLPE/ARCTIC-PVC, Instrumentation, Shielded
600 V, UL Type TC, CSA Type CIC, Overall Shielded Pairs/Triads
Product Construction:
Conductor:

• 18 AWG and 16 AWG tinned, annealed copper per
ASTM B3
• Class B stranding per ASTM B8	

Insulation:

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. OF COND.
THICKNESS
THICKNESS
CABLE
O.D.
PAIRS/ SIZE COND.
LBS/
LBS/
TRIADS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

OVERALL SHIELDED PAIRS/TRIADS
18 AWG CONDUCTORS
366170*
347630*
347640*
347650*
347660*
347670*
347680*
347690*
347700*
347710*
347720*

1
1 TRI
2
4
8
12
16
20
24
36
50

18
18
18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.060
0.080
0.080
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.52
2.03
2.03
2.03
2.03
2.03
2.03

0.315
0.340
0.450
0.560
0.750
0.850
1.010
1.085
1.210
1.500
2.570

8.00
8.64
11.43
14.22
19.05
21.59
25.65
27.56
30.73
38.10
65.28

12
18
23
44
94
141
187
233
279
418
580

18
26
34
65
140
210
278
347
415
622
863

46
68
57
85
88 131
144 214
263 391
358 533
461 686
600 893
761 1043
1005 1496
1603 2386

OVERALL SHIELDED PAIRS/TRIADS
16 AWG CONDUCTORS
366180*
347730*
347740*
347750*
347760*
347770*
347780*
347790*
347800*
347810*
347820*

1
1 TRI
2
4
8
12
16
20
24
36
50

16
16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.110

1.14
1.14
1.14
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.79

0.345
0.360
0.560
0.650
0.810
1.000
1.120
1.170
1.440
1.650
2.020

8.76
9.14
14.22
16.51
20.57
25.40
28.45
29.72
36.58
41.91
51.31

19
28
27
40
36
53
69 102
135 201
202 300
268 399
335 498
401 597
601 894
834 1241

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

32
71
121
186
324
486
616
734
894
1254
1800

48
106
181
277
482
723
917
1092
1330
1866
2679

• Lead-free, flame-retardant Cross-linked
Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black
and white; Triads - black, white, and red. One
conductor in each pair or triad is printed alphanumerically for easy identification

Shield:

Overall shielded pairs/triads
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, flame-retardant, sunlight-resistant
Arctic-grade Polyvinyl Chloride (PVC)

Print:

• GENERAL CABLE ® (PLANT OF MFG) (UL) TYPE
TC ARCTIC-FLEX® FR-XLP/PVC XX PS/TS XX
AWG SHIELDED 90C WET OR DRY SUN RES
DIR BUR 600 V - CSA TYPE CIC SHIELDED
INSTRUMENTATION CABLE XLPE 90C WET OR
DRY -40C FT4 PLUS DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK	

Options:

• Bare copper
• Class C stranding
• E-2 Color Code
• CSA Rated TC for 14 AWG and larger
• Other constructions available upon request

Applications:

• Industrial lighting, control and signaling circuits
• Primary installations in cable trays, raceways or
outdoor applications where supported by a
messenger wire
• In wet or dry locations

Features:

• Rated 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Sunlight- and weather-resistant
• Meets CSA cold impact test at -40˚C
• Meets ICEA and CSA cold bend test at -60˚C

Compliances:

Industry Compliances:
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • CSA C22.2 No. 239 Type CIC
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • CSA FT4
	 • IEEE 383
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to lengths and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 2300

March, 2012

Arctic-Flex

®

XLPE/ARCTIC-PVC, Instrumentation, Shielded
600 V, UL Type TC, CSA Type CIC, Individual and Overall Shielded Pairs
Product Construction:
Conductor:

• 18 AWG and 16 AWG tinned, annealed copper per
ASTM B3
• Class B stranding per ASTM B8	

Insulation:

• Lead-free, flame-retardant Cross-linked
Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black and
white. One conductor in each pair is printed alphanumerically for easy identification

Shield:

Individual and overall shielded pairs
• Individual pairs are 100% shielded with Flexfoil®
aluminum/polyester in contact with stranded
tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, flame-retardant, sunlight-resistant
Arctic-grade Polyvinyl Chloride (PVC)

Print:

• GENERAL CABLE ® (PLANT OF MFG) (UL) TYPE
TC ARCTIC-FLEX® FR-XLP/PVC XX SPS/STS
XX AWG SHIELDED 90C WET OR DRY SUN
RES DIR BUR 600 V - CSA TYPE CIC SHIELDED
INSTRUMENTATION CABLE XLPE 90C WET OR
DRY -40C FT4 PLUS DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK	

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
COND.
THICKNESS
THICKNESS
CABLE
O.D.
NO. OF SIZE COND.
LBS/
LBS/
PAIRS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

INDIVIDUAL AND OVERALL SHIELDED PAIRS
18 AWG CONDUCTORS
347830*
347840*
347850*
347860*
347870*
347880*
347890*
347900*
347910*

2
4
8
12
16
20
24
36
50

Applications:

• Industrial lighting, control and signaling circuits
• Primary installations in cable trays, raceways or
outdoor applications where supported by a
messenger wire
• In wet or dry locations

Features:

• Rated 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Sunlight- and weather-resistant
• Meets CSA cold impact test at -40˚C
• Meets ICEA and CSA cold bend test at -60˚C

Compliances:

Industry Compliances:
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • CSA C22.2 No. 239 Type CIC
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • CSA FT4
	 • IEEE 383
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to lengths and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.110

1.14
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.79

0.515
0.625
0.805
1.020
1.130
1.235
1.465
1.630
1.975

13.08
15.88
20.45
25.91
28.70
31.37
37.21
41.40
50.17

30
55
105
156
207
252
308
461
640

45
93 138
82 167 248
156 304 460
232 449 668
308 554 824
375 666 991
458 794 1182
686 1122 1670
952 1598 2378

INDIVIDUAL AND OVERALL SHIELDED PAIRS
16 AWG CONDUCTORS

Options:

• Bare copper
• Class C stranding
• E-2 Color Code
• CSA Rated TC for 14 AWG and larger
• Other constructions available upon request

18
18
18
18
18
18
18
18
18

347920*
347930*
347940*
347950*
347960*
347970*
347980*
347990*
348000*

2
4
8
12
16
20
24
36
50

16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.110
0.110

1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.79
2.79

0.595
0.695
0.900
1.110
1.260
1.315
1.510
1.820
2.095

15.11
17.65
22.86
28.19
32.00
33.40
38.35
46.23
53.21

42
63 132
80
119
212
155 231 395
230 342 578
306 455 733
375 558 845
456 679 1009
674 1003 1259
946 1408 2032

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

196
315
588
860
1091
1258
1502
1874
3024

SPEC 2350

March, 2012

CVTC

®

XLPE/PVC, Instrumentation, Shielded
600 V, UL Type TC, Overall Shielded Pairs/Triads
Product Construction:
Conductor:

• 18 AWG and 16 AWG bare, annealed
copper per ASTM B3
• Class B stranding per ASTM B8

Insulation:

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. OF COND.
THICKNESS
THICKNESS
CABLE
O.D.
PAIRS/ SIZE COND.
LBS/
LBS/
TRIADS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

OVERALL SHIELDED PAIRS/TRIADS
18 AWG CONDUCTORS
366160*
337270*
337360*
337280*
337290*
337300*
337310*
337320*
337330*
337340*
337350*

1
1 TRI
2
4
8
12
16
20
24
36
50

18
18
18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.060
0.080
0.080
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.52
2.03
2.03
2.03
2.03
2.03
2.03

0.315
0.340
0.450
0.560
0.750
0.850
1.010
1.085
1.210
1.500
2. 570

8.00
8.64
11.43
14.22
19.05
21.59
25.65
27.56
30.73
38.10
65.28

1
1 TRI
2
4
8
12
16
20
24
36
50

16
16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.110

1.14
1.14
1.14
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.79

0.345
0.360
0.560
0.650
0.810
1.000
1.120
1.170
1.440
1.650
2.020

8.76
9.14
14.22
16.51
20.57
25.40
28.45
29.72
36.58
41.91
51.31

Shield:

Overall shielded pairs/triads
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:
12
18
23
44
94
141
187
233
279
418
580

18
26
34
65
140
210
278
347
415
622
863

46
68
58
86
88
131
144 214
263 391
358 533
461 686
600 893
701 1043
1005 1496
1603 2386

19
27
36
69
135
202
268
335
401
601
834

28
32
48
40
72
107
53
121 180
102 186 277
201 324 482
300 486 723
399 616 917
498 734 1092
597 894 1330
894 1254 1866
1241 1800 2679

OVERALL SHIELDED PAIRS/TRIADS
16 AWG CONDUCTORS
319810*
319870*
337370*
382260*
337390*
337400*
337410*
337420*
337430*
337440*
337450*

• Flame-retardant Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black
and white; Triads - black, white and red. One
conductor in each pair or triad is printed alphanumerically for easy identification

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

• Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Print:

• GENERAL CABLE ® (PLANT OF MFG) CVTC®
XX/PS/TS XXAWG FR-XLP/PVC SHIELDED (UL)
TYPE TC 90˚C WET OR DRY DIR BUR SUN RES
600 V MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

Options:

• 300 V Type PLTC
• Tinned copper conductor
• Class C stranding
• Individual and overall shielded pairs/triads
• EVTC—Ethylene Propylene Rubber (EPR)
insulation
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Abrasion- and chemical-resistant
• Excellent electrical properties
• Sunlight- and weather-resistant
• Meets cold bend test at -25˚C

Compliances:

Industry Compliances:
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • ICEA T-29-520 (210,000 BTU/hr)
	 • CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 2400
March, 2012

CVTC

®

XLPE/PVC, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Pairs
Product Construction:
Conductor:

• 18 AWG and 16 AWG bare, annealed
copper per ASTM B3
• Class B stranding per ASTM B8

Insulation:

• Flame-retardant Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black and
white. One conductor in each pair is printed alphanumerically for easy identification

Shield:

Individual and overall shielded pairs
• Individual pairs are 100% shielded with Flexfoil®
aluminum/polyester in contact with stranded
tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Print:

• GENERAL CABLE ® (PLANT OF MFG) CVTC®
XX/SPS XXAWG FR-XLP/PVC SHIELDED (UL)
TYPE TC 90˚C WET OR DRY DIR BUR SUN
RES 600 V PLUS MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

Options:

• 300 V Type PLTC
• Tinned copper conductor
• Class C stranding
• Overall shielded pairs/triads
• EVTC—Ethylene Propylene Rubber (EPR)
insulation
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Abrasion- and chemical-resistant
• Excellent electrical properties
• Sunlight- and weather-resistant
• Meets cold bend test at -25˚C

Compliances:

Industry Compliances:
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • ICEA T-29-520 (210,000 BTU/hr)
	 • CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
COND.
THICKNESS
THICKNESS
CABLE
O.D.
NO. OF SIZE COND.
LBS/
LBS/
PAIRS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

INDIVIDUAL AND OVERALL SHIELDED PAIRS
18 AWG CONDUCTORS
319820*
319840*
319850*
337460*
337470*
337480*
337490*
337500*
337510*

2
4
8
12
16
20
24
36
50

18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.110

1.14
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.79

0.515
0.625
0.805
1.020
1.130
1.235
1.465
1.630
1.975

13.08
15.88
20.45
25.91
28.70
31.37
37.21
41.40
50.17

28
53
104
155
206
254
308
461
640

41
95 141
53
170 253
155 292 435
231 442 658
307 554 824
378 666 991
459 802 1194
687 1116 1661
952 1598 2378

INDIVIDUAL AND OVERALL SHIELDED PAIRS
16 AWG CONDUCTORS
337520*
337530*
337540*
337550*
337560*
337570*
337580*
337590*
337600*

2
4
8
12
16
20
24
36
50

16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.110
0.110

1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.79
2.79

0.595
0.695
0.900
1.110
1.260
1.315
1.510
1.820
2.095

15.11
17.65
22.86
28.19
32.00
33.40
38.35
46.23
53.21

40
78
153
229
304
380
455
682
946

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

60 135 201
116
214 318
228 399 594
341 584 869
453
712 1060
566 845 1258
677 1009 1502
1014 1259 1874
1408 2032 3024

SPEC 2450

March, 2012

VNTC

®

PVC/Nylon/PVC, Instrumentation, Shielded
600 V, UL Type TC, Overall Shielded Pairs/Triads
Product Construction:
Conductor:

• 18 AWG thru 14 AWG bare, annealed
copper per ASTM B3
• Class B stranding per ASTM B8

Insulation:

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. OF COND.
THICKNESS
THICKNESS
CABLE
O.D.
PAIRS/ SIZE COND.
LBS/
LBS/
TRIADS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

OVERALL SHIELDED PAIRS/TRIADS
18 AWG CONDUCTORS
1
235020
239210 1 TRI
2
235910
3
319740*
4
235980
5
336830*
7
336840*
230760* 12
16
270970*
336850* 20
230750* 24
230800* 36
336860* 50

18
18
18
18
18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03

0.280
0.300
0.440
0.465
0.505
0.570
0.585
0.770
0.825
0.905
1.020
1.150
1.405

7.11
7.62
11.18
11.81
12.83
14.48
14.86
19.56
20.96
22.99
25.91
29.21
35.69

12
18
23
33
44
55
75
127
168
210
252
378
525

19
41
61
27
49
73
34
72 107
50
90 134
65
110 164
82 144 214
112
177 263
189 277 412
250 355 528
313 455 677
375 544 810
562 763 1135
781 1036 1542

20
27
37
53
69
87
117
201
267
337
398
595
833

29
52
77
40
61
91
54
93 138
79
117 174
103 160 238
129 190 283
174 239 356
299 370 551
397
513 763
502 628 935
592
740 1101
886 1063 1582
1240 1435 2136

OVERALL SHIELDED PAIRS/TRIADS
16 AWG CONDUCTORS
1
230830
230840 1 TRI
2
238410*
3
239200*
4
230790*
5
336870*
7
336880*
244590* 12
16
244610*
336890* 20
230780* 24
230820* 36
230810* 50

16
16
16
16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03

0.300
0.315
0.470
0.505
0.575
0.610
0.630
0.825
0.970
1.010
1.135
1.375
1.570

7.62
8.00
11.94
12.83
14.61
15.49
16.00
20.96
24.64
25.65
28.83
34.93
39.88

OVERALL SHIELDED PAIRS/TRIADS
14 AWG CONDUCTORS
237490

1

14

7/.0242 0.015 0.38 0.045 1.14 0.325

8.26

28

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

42

62

92

• Flame-retardant Polyvinyl Chloride (PVC) with
clear Polyamide (nylon)
• Color-coded per ICEA Method 1: Pairs - black
and white; Triads - black, white and red. One
conductor in each pair or triad is printed alphanumerically for easy identification

Shield:

Overall shielded pairs/triads
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Print:

• GENERAL CABLE ® (PLANT OF MFG) VNTC®
XX/PS/TS XXAWG SHIELDED (UL) TYPE TC 600
V TFN SUN RES DIR BUR ROHS DAY/MONTH/
YEAR OF MFG SEQUENTIAL FOOTAGE MARK

Options:

• Tinned copper conductor
• Class C stranding
• Individual and overall shielded pairs/triads
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

Features:

• Rated at 90˚C dry, 75˚C wet
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Provides sunlight, cold bend and cold impact
resistance
• Offer the smallest cable O.D. available for suitable
applications
• Provides excellent oil and chemical resistance
• Provides a long service life
• Meets cold bend test at -25˚C

Compliances:

Industry Compliances:
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • NEC Type TFN conductors
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable
	 • RoHS Compliant

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 2500
March, 2012

VNTC

®

PVC/Nylon/PVC, Instrumentation, Shielded
600 V, UL Type TC, Individual and Overall Shielded Pairs
Product Construction:
Conductor:

• 18 AWG and 16 AWG bare, annealed
copper per ASTM B3
• Class B stranding per ASTM B8

Insulation:

• Flame-retardant Polyvinyl Chloride (PVC) with
clear Polyamide (nylon)
• Color-coded per ICEA Method 1: Pairs - black and
white. One conductor in each pair is printed alphanumerically for easy identification

Shield:

Individual and overall shielded pairs
• Individual pairs are 100% shielded with Flexfoil®
aluminum/polyester in contact with stranded
tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Print:

•G
 ENERAL CABLE ® (PLANT OF MFG) VNTC®
XX/SPS XXAWG SHIELDED (UL) TYPE TC 600 V
TFN SUN RES DIR BUR ROHS PLUS DAY/
MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE
MARK

Options:

• Tinned copper conductor
• Class C stranding
• Overall shielded pairs/triads
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

Features:

• Rated at 90˚C dry, 75˚C wet
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Provides sunlight, cold bend and cold impact
resistance
• Offer the smallest cable O.D. available for suitable
applications
• Provides excellent oil and chemical
resistance
• Provides a long service life
• Meets cold bend test at -25˚C

Compliances:

Industry Compliances:
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • NEC Type TFN conductors
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable
	 • RoHS Compliant

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
COND.
THICKNESS
THICKNESS
CABLE
O.D.
NO. OF SIZE COND.
LBS/
LBS/
PAIRS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

INDIVIDUAL AND OVERALL SHIELDED PAIRS
18 AWG CONDUCTORS
235970*
336900*
235900*
336910*
336920*
241020*
336930*
336940*
241030*
243880*
256300*

2
3
4
5
7
12
16
20
24
36
50

18
18
18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03

0.445
0.480
0.555
0.580
0.650
0.845
0.960
1.050
1.175
1.380
1.615

11.30
12.19
14.10
14.73
16.51
21.46
24.38
26.67
29.85
35.05
41.02

28
41
46
68
53
79
74
110
102 152
193 287
229 341
283 421
340 506
508 756
705 1049

84 125
106 158
145 216
169 252
219 326
390 506
473 704
594 884
689 1025
979 1457
1371 1960

INDIVIDUAL AND OVERALL SHIELDED PAIRS
16 AWG CONDUCTORS
237180
235990*
237160
336950*
336960*
235750
242870
237130*
277820*
242860*
243890*
244600*

2
3
4
5
7
8
12
16
20
24
36
50

16
16
16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03

0.495
0.520
0.600
0.655
0.710
0.760
0.940
1.055
1.175
1.350
1.480
1.810

12.57
44
65 105
13.21
64
95
137
15.24
84
125 188
16.64 105
157 224
18.03 145
216 290
19.30 155 224 307
23.88 244 363 498
26.80 324 482 635
29.85 407 605 768
34.29 486 724 903
37.59 732 1089 1290
45.97 1011 1504 1809

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

156
204
280
333
432
457
741
945
1143
1344
1920
2692

SPEC 2600

March, 2012

GenFree

®

XLPE/LSZH, Instrumentation, Shielded
600 V, UL Type TC-LS, Overall Shielded Pairs/Triads
Product Construction:
Conductor:

• 18 AWG and 16 AWG tinned, annealed copper per
ASTM B33
• Class B stranding per ASTM B8

Insulation:

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. OF COND.
THICKNESS
THICKNESS
CABLE
O.D.
PAIRS/ SIZE COND.
LBS/
LBS/
TRIADS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

OVERALL SHIELDED PAIRS/TRIADS
18 AWG CONDUCTORS
1
393710*
393720* 1 TRI
2
393730*
4
393740*
8
393750*
393760* 12
393770* 16
393780* 20
393790* 24
393800* 36
393810* 50

18
18
18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.060
0.080
0.080
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.52
2.03
2.03
2.03
2.03
2.03
2.03

0.315
0.340
0.450
0.560
0.750
0.850
1.010
1.085
1.210
1.500
2.570

8.00
8.64
11.43
14.22
19.05
21.59
25.65
27.56
30.73
38.10
65.28

16
16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.110

1.14
1.14
1.14
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.79

0.345
0.360
0.560
0.650
0.810
1.000
1.120
1.170
1.440
1.650
2.020

8.76
9.14
14.22
16.51
20.57
25.40
28.45
29.72
36.58
41.91
51.31

Shield:

Overall shielded pairs/triads
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:
13
18
23
44
86
127
169
210
252
377
523

19
26
34
65
127
189
251
313
375
561
778

46 68
58 86
88 131
144 214
263 391
358 533
461 686
600 893
701 1043
1005 1496
1603 2386

OVERALL SHIELDED PAIRS/TRIADS
16 AWG CONDUCTORS
1
393820
393830 1 TRI
2
393840*
4
393850*
8
393860*
393870* 12
393880* 16
393890* 20
393900* 24
393910* 36
393920* 50

• Lead-free, flame-retardant, low-smoke
Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black
and white; Triads - black, white and red. One
conductor in each pair or triad is printed alphanumerically for easy identification

18
28
26
39
36
54
69 103
135 201
202 300
268 399
335 498
401 597
601 894
834 1241

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

32
72
121
186
324
486
616
734
894
1254
1800

48
107
180
277
482
723
917
1092
1330
1866
2679

• Lead-free, flame-retardant, sunlight-resistant,
Low-Smoke, Zero-Halogen Polyolefin (LSZH)

Print:

• GENERAL CABLE ® (PLANT OF MFG) GENFREE®
XX/PS/TS XXAWG XLPE/LSZH SHIELDED (UL)
TYPE TC-LS 90˚C WET OR DRY 600 V DIR BUR
SUN RES ROHS DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

Options:

• Class C stranding
• Individual and overall shielded pairs/triads
• Other constructions available upon request

Applications:

• In free air, raceways, aerial or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical and electrical properties
• Excellent moisture resistance
• Excellent resistance to compression and impact
• Chemical-resistant
• Low coefficient of friction for easy pulling
• Sunlight- and weather-resistant
• Meets cold bend test at -30˚C
• Low-Smoke, Zero-Halogen jacket is
environmentally safe
• Low-Smoke, Zero-Halogen jacket reduces the
amount of toxic and corrosive gases emitted
during combustion, providing a safer environment
for personnel and equipment during the hazards
of fire

Compliances:

Industry Compliances:
	 • UL 1277 Type TC-LS, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
	 • ICEA T-33-655
	 • RoHS Compliant
Flame Test Compliances:
	 • UL 1581
	 • UL 1685 Vertical Flame Test
	 • IEEE 1202
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 2625

March, 2012

GenFree

®

XLPE/LSZH, Instrumentation, Shielded
600 V, UL Type TC-LS, Individual and Overall Shielded Pairs
Product Construction:
Conductor:

• 18 AWG and 16 AWG tinned, annealed copper per
ASTM B33
• Class B stranding per ASTM B8

Insulation:

• Lead-free, flame-retardant, low-smoke
Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black and
white. One conductor in each pair is printed alphanumerically for easy identification

Shield:

Individual and overall shielded pairs
• Individual pairs are 100% individually shielded
with Flexfoil® aluminum/polyester in contact with
stranded tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, flame-retardant, sunlight-resistant
Low-Smoke, Zero-Halogen Polyolefin (LSZH)

Print:

• GENERAL CABLE ® (PLANT OF MFG) GENFREE®
XX/SPS XXAWG XLPE/LSZH SHIELDED (UL)
TYPE TC-LS 90˚C WET OR DRY 600 V DIR BUR
SUN RES ROHS DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

Options:

• Class C stranding
• Overall shielded pairs
• Other constructions available upon request

Applications:

• In free air, raceways, aerial or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical and electrical properties
• Excellent moisture resistance
• Excellent resistance to compression and impact
• Chemical-resistant
• Low coefficient of friction for easy pulling
• Sunlight- and weather-resistant
• Meets cold bend test at -30˚C
• Low-Smoke, Zero-Halogen jacket is
environmentally safe
• Low-Smoke, Zero-Halogen jacket reduces the
amount of toxic and corrosive gases emitted during
combustion, providing a safer environment for
personnel and equipment during the hazards of fire

Compliances:

Industry Compliances:
	 • UL 1277 Type TC-LS, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
	 • ICEA T-33-655
	 • RoHS Compliant
Flame Test Compliances:
	 • UL 1581
	 • UL 1685 Vertical Flame Test
	 • IEEE 1202
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
COND.
THICKNESS
THICKNESS
CABLE
O.D.
NO. OF SIZE COND.
LBS/
LBS/
PAIRS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

INDIVIDUAL AND OVERALL SHIELDED PAIRS
18 AWG CONDUCTORS
393930
393940
393950*
393960*
393970*
393980*
393990*
394000*
394010*

2
4
8
12
16
20
24
36
50

18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.060
0.080
0.080
0.080
0.080
0.080
0.010
0.010

1.14
1.52
2.03
2.03
2.03
2.03
2.03
2.79
2.79

0.510
0.630
0.855
1.030
1.140
1.265
1.450
1.650
2.085

12.95
16.00
21.72
26.16
28.96
32.13
36.83
41.91
52.96

27
53
103
153
206
254
311
461
640

41
92
137
78 167 249
153 326 485
228 441 656
307 554 824
378 676 1006
463 795 1183
687 1118 1664
952 1616 2405

INDIVIDUAL AND OVERALL SHIELDED PAIRS
16 AWG CONDUCTORS
394020
394030
394040
394050
394060
394070*
394080*
394090*
394100*
394110*

2
4
6
8
12
16
20
24
36
50

16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.110
0.110

1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.79
2.79

0.585
0.675
0.800
0.915
1.110
1.350
1.365
1.570
1.980
2.165

14.86
17.15
20.32
23.24
28.19
34.29
34.67
39.88
50.29
54.99

40
77
115
151
226
305
380
455
683
946

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

59 130 193
114 204 304
171 301 447
225 394 586
337 548
816
453 713 1061
566 850 1265
677 1001 1490
1016 1548 2304
1408 2020 3006

SPEC 2650

March, 2012

GenFree

®

XLPE/LSZH, Instrumentation, Shielded
600 V, UL Type TC-LS, Individual and Overall Shielded Triads
Product Construction:
Conductor:

• 18 AWG and 16 AWG tinned, annealed copper per
ASTM B33
• Class B stranding per ASTM B8

Insulation:

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
COND.
THICKNESS
THICKNESS
CABLE
O.D.
NO. OF SIZE COND.
LBS/
LBS/
TRIADS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

INDIVIDUAL AND OVERALL SHIELDED TRIADS
18 AWG CONDUCTORS
394120* 2 TRI
394130* 4 TRI
394140* 8 TRI
394150* 12 TRI
394160* 16 TRI
394170* 20 TRI
394180* 24 TRI
394190* 36 TRI

18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.110

1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.79

0.595
0.690
0.940
1.135
1.265
1.405
1.565
1.860

15.11
17.53
23.88
28.83
32.13
35.69
39.75
47.24

38
74
145
217
289
361
432
647

57 150
110 231
216 435
323
612
430 773
537 935
643 1097
963 1662

223
344
647
911
1150
1391
1633
2473

INDIVIDUAL AND OVERALL SHIELDED TRIADS
16 AWG CONDUCTORS
394200*
394210*
394220*
394230*
394240*
394250*
394260*
394270*

2 TRI
4 TRI
8 TRI
12 TRI
16 TRI
20 TRI
24 TRI
36 TRI

16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.060
0.060
0.080
0.080
0.080
0.080
0.110
0.110

1.52
1.52
2.03
2.03
2.03
2.03
2.79
2.79

0.640
0.745
1.015
1.230
1.370
1.525
1.760
2.015

16.26
18.92
25.78
31.24
34.80
38.74
44.70
51.18

57
84 183 272
111 165 494 735
219 326 549 817
328 487 777 1156
437 650 988 1470
545 811 1120 1667
654 973 1530 2277
979 1457 2142 3188

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

• Lead-free, flame-retardant, low-smoke
Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Triads - black,
white and red. One conductor in each triad is
printed alpha-numerically for easy identification

Shield:

Individual and overall shielded triads
• Individual triads are 100% shielded with Flexfoil®
aluminum/polyester in contact with stranded
tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, flame-retardant, sunlight-resistant
Low-Smoke, Zero-Halogen Polyolefin (LSZH)

Print:

• GENERAL CABLE ® (PLANT OF MFG) GENFREE®
XX/STS XXAWG XLPE/LSZH SHIELDED (UL)
TYPE TC-LS 90˚C WET OR DRY 600 V DIR BUR
SUN RES ROHS DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

Options:

• Class C stranding
• Overall shielded pairs/triads
• Other constructions available upon request

Applications:

• In free air, raceways, aerial or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical and electrical properties
• Excellent moisture resistance
• Excellent resistance to compression and impact
• Chemical-resistant
• Low coefficient of friction for easy pulling
• Sunlight- and weather-resistant
• Meets cold bend test at -30˚C
• Low-Smoke, Zero-Halogen jacket is
environmentally safe
• Low-Smoke, Zero-Halogen jacket reduces the
amount of toxic and corrosive gases emitted during
combustion, providing a safer environment for
personnel and equipment during the hazards of fire

Compliances:

Industry Compliances:
	 • UL 1277 Type TC-LS, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
	 • ICEA T-33-655
	 • RoHS Compliant
Flame Test Compliances:
	 • UL 1581
	 • UL 1685 Vertical Flame Test
	 • IEEE 1202
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

Date of Issue 06/13
Section 3		

Industrial Cables

600 V Flexible Control and Power Cables
SPECIFICATION NO.

PRODUCT DESCRIPTION

REVISION DATE

3150

NVN

PVC/Nylon/Neoprene, Thermoset Flexible Control
600 V, UL Type TC

Jan. 2010

3250

MTW

PVC/Nylon/PVC, Thermoplastic Flexible Control
600 V, UL Type MTW/CSA AWM

Jan. 2010

3300

Festoon

PVC/PVC, Thermoplastic Extreme Flexing Festoon Control and Power
600 V, UL/CSA Type Festoon

Jan. 2010

®

Phone: 888-593-3355
www.generalcable.com

SPEC 3150

January, 2010

NVN

®

PVC/Nylon/Neoprene, Thermoset Flexible Control
600 V, UL Type TC
Product Construction:
Conductor:

• 18 AWG thru 12 AWG fully annealed stranded bare
copper per ASTM B3
• Class C stranding per ASTM B8

Insulation:

COPPER
MINIMUM AVG. MINIMUM AVG.
MINIMUM
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
BEND
COND.
RADIS
CATALOG NO. OF SIZE COND. THICKNESS THICKNESS CABLE O.D. LBS/
LBS/
NUMBER COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km INCHES mm

18 AWG CONDUCTORS
554420*
624740*
624750*
624760*
624010*
624780*
624790*
686890*

4
8
10
12
16
19
24
30

18
18
18
18
18
18
18
18

19/.0092
19/.0092
19/.0092
19/.0092
19/.0092
19/.0092
19/.0092
19/.0092

0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52

0.310
0.420
0.450
0.465
0.515
0.570
0.660
0.695

7.87 21
10.67 42
11.43 53
11.81 63
13.08 85
14.48 100
16.76 127
17.65 158

31
63
79
94
126
149
189
235

65
116
135
137
175
192
297
345

97
173
201
204
260
286
442
513

2.5
3.3
3.6
3.7
4.1
4.6
5.3
5.6

63.5
83.8
91.5
94.0
104.1
116.8
134.6
142.2

16 AWG CONDUCTORS
625160*
625200*
625220*
625230*
625250*
625270*
625280*
625290*

4
8
10
12
16
19
24
30

16
16
16
16
16
16
16
16

19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117

0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

624950*
624980*
624990*
625000*
625020*
625030*
625040*
625050*

4
8
10
12
16
19
24
30

14
14
14
14
14
14
14
14

19/.0147
19/.0147
19/.0147
19/.0147
19/.0147
19/.0147
19/.0147
19/.0147

0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

324820*
624850*
624860*
624870*
624890*
624900*
624910*
624920*

4
8
10
12
16
19
24
30

12
12
12
12
12
12
12
12

19/.0185
19/.0185
19/.0185
19/.0185
19/.0185
19/.0185
19/.0185
19/.0185

0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52

0.345
0.465
0.500
0.520
0.605
0.635
0.735
0.775

8.76
11.81
12.70
13.21
15.37
16.13
18.67
19.69

33
66
83
100
133
158
199
249

49
98
124
149
198
235
296
371

85
153
179
186
257
320
403
476

126
228
266
277
382
476
600
708

2.8
3.7
4.0
4.2
4.8
5.1
5.9
6.2

71.1
94.0
101.6
106.7
121.9
129.5
149.9
157.5

53
105
132
158
210
250
316
394

79
156
196
235
313
372
470
586

117
181
270
278
353
449
565
727

174
269
402
414
525
668
841
1082

3.0
3.9
4.8
4.9
5.4
5.7
6.6
7.4

76.2
99.1
121.9
124.5
137.2
144.8
167.6
188.0

84
167
209
250
334
397
501
626

125
249
311
372
497
591
746
932

157 234
272 405
369 549
389 579
503 749
638 949
841 1252
1017 1513

3.4
4.6
5.4
5.5
6.1
6.5
7.8
8.3

86.4
116.9
137.2
139.7
155.0
165.1
198.1
210.8

14 AWG CONDUCTORS
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.52
1.52
1.52
1.52
1.52
2.03

0.375
0.485
0.595
0.615
0.675
0.710
0.825
0.920

9.53
12.32
15.11
15.62
17.15
18.03
20.96
23.37

• Flame-retardant Polyvinyl Chloride (PVC) with
clear Polyamide (nylon)
• Color-coded per ICEA Method 1, Table E-2 (does
not include white or green)

Jacket:

• Thermosetting Neoprene

Print:

• GENERAL CABLE ® BRAND REX BRAND
(PLANT OF MFG) NVN 90˚C FLEXIBLE CONTROL
CABLE 600 V TYPE TC SUN RES XX/C XXAWG
(TFFN) OR (THHN/THWN) (UL)

Applications:

• Tight installations
• Trays, conduits and raceways
• Cranes and hoists
• Pendant stations
• Load lifts and platforms
• Recommended for moderate flex applications

Features:

• Rated at 90˚C
• Moderate flex cable
• Small diameter
• Thermosetting rubber jacket
• Flame-retardant
• Suitable for indoor and outdoor applications
• Meets cold bend test at -40˚C

Compliances:

Industry Compliances:
	 • UL Type TC - 600 V, UL File # E57179
Flame Test Compliances:
	 • IEEE 1202 (70,000 BTU/hr)
	 • IEEE 383 (70,000 BTU/hr)
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

12 AWG CONDUCTORS
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.060
0.060
0.060
0.060
0.060
0.080
0.080

1.14
1.52
1.52
1.52
1.52
1.52
2.03
2.03

0.420
0.575
0.670
0.690
0.765
0.805
0.980
1.040

10.67
14.61
17.02
17.53
19.43
20.45
24.89
26.42

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

SPEC 3250

January, 2010

MTW

PVC/Nylon/PVC, Thermoplastic Flexible Control
600 V, UL Type MTW/CSA AWM
Product Construction:
Conductor:

•	18 AWG thru 10 AWG fully annealed stranded bare
copper per ASTM B3
•	Class M-18 AWG thru 16 AWG
•	Class K-14 AWG thru 10 AWG
•	Stranding per ASTM B8

Insulation:

•	Flame-retardant Polyvinyl Chloride (PVC) with
clear Polyamide (nylon)
•	Color-coded: all conductors red, except #2 is
white and #3 is green. All with alpha-numeric
designations

Jacket:

•	Heat-, moisture- and oil-resistant Polyvinyl
Chloride (PVC)

Print:

•	GENERAL CABLE® BRAND REX BRAND
(PLANT OF MFG) TYPE MTW FLEXING 600 V
(UL) NO OF COND/AWG SIZE/CSA AWM IIA
90˚C 600 V FT1

Applications:

•	Pendant cable
•	Machine tool
•	Internal machine connections
•	Material handling equipment
•	Moderate flex

Features:

•	Rated at 90˚C
•	Moisture- and oil-resistant
•	Heavy-duty PVC jacket
•	Meets cold bend test at -25˚C

Compliances:

Industry Compliances:
	 •	UL Type MTW/CSA AWM
Other Compliances:
	 •	EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 •	OSHA Acceptable
	 • RoHS Compliant

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

COPPER
MINIMUM AVG. MINIMUM AVG.
MINIMUM
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
BEND
COND.
RADIUS
CATALOG NO. OF SIZE COND. THICKNESS THICKNESS CABLE O.D. LBS/
LBS/
NUMBER COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km INCHES mm

18 AWG CONDUCTORS
339170*
339180*
339190*
339200*
339210*
339220*
339230*
339240*

6
8
12
16
22
31
41
60

18
18
18
18
18
18
18
18

41/34
41/34
41/34
41/34
41/34
41/34
41/34
41/34

0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

339250*
339260*
339270*
339280*
339290*
339300*
339310*
339320*

6
8
12
16
22
31
41
60

16
16
16
16
16
16
16
16

65/34
65/34
65/34
65/34
65/34
65/34
65/34
65/34

0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

339330* 6
339340* 8
339350* 12
339360* 16
339370* 22

14
14
14
14
14

41/30
41/30
41/30
41/30
41/30

0.020
0.020
0.020
0.020
0.020

339380* 6
339390* 8
339400* 12
339410* 16
339420* 22

12
12
12
12
12

65/30
65/30
65/30
65/30
65/30

0.020
0.020
0.020
0.020
0.020

339430* 6
339440* 8
339450* 12
339460* 16

10
10
10
10

105/30
105/30
105/30
105/30

0.026
0.026
0.026
0.026

0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080

1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03

0.400
0.455
0.500
0.580
0.660
0.760
0.890
1.010

10.16
11.56
12.70
14.73
16.76
19.30
22.61
25.65

32
42
63
84
116
163
216
316

48
63
94
125
173
243
321
470

88
108
144
196
252
325
460
617

131
161
214
292
375
484
685
918

3.0 76.2
3.5 88.9
4.0 101.6
4.5 114.3
5.0 127.0
6.0 152.4
7.0 177.8
8.0 203.2

50
66
99
132
182
256
339
496

74
98
147
196
271
381
504
738

113 168
141 210
214 318
263 391
377 561
518 771
652 970
909 1353

3.5 88.9
4.0 101.6
4.5 114.3
5.0 127.0
5.5 139.7
6.5 165.1
8.0 203.2
9.0 228.2

80
107
160
213
293

119
159
238
317
436

149
204
279
354
467

222
304
415
527
695

3.5
4.5
5.0
5.5
6.0

88.9
114.3
127.0
139.7
152.4

129
172
258
344
473

192
256
384
512
704

226 336
289 430
398 592
506 753
720 1072

4.5
5.0
5.5
6.0
7.5

114.3
127.0
139.7
152.4
190.0

205
274
411
548

305
408
612
816

329 490
424 631
604 899
852 1268

5.0 127.0
6.0 152.4
7.0 177.8
9.0 228.6

16 AWG CONDUCTORS
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080

1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03

0.440
0.500
0.585
0.640
0.735
0.845
0.995
1.125

11.18
12.70
14.86
16.26
18.67
21.46
25.27
28.58

14 AWG CONDUCTORS
0.51
0.51
0.51
0.51
0.51

0.045
0.060
0.060
0.060
0.060

1.14
1.52
1.52
1.52
1.52

0.470
0.570
0.630
0.690
0.795

11.94
14.48
16.00
17.53
20.19

12 AWG CONDUCTORS
0.51
0.51
0.51
0.51
0.51

0.060
0.060
0.060
0.060
0.080

1.52
1.52
1.52
1.52
2.03

0.565
0.645
0.715
0.790
0.955

14.35
16.38
18.16
20.07
24.26

10 AWG CONDUCTORS
0.66
0.66
0.66
0.66

0.060
0.060
0.080
0.080

1.52
1.52
2.03
2.03

0.665
0.765
0.895
1.155

16.89
19.43
22.73
29.34

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

SPEC 3300

January, 2010

Festoon

PVC/PVC, Thermoplastic Extreme Flexing Festoon Control and Power
600 V, UL/CSA Type Festoon
Product Construction:
Conductor:

• 16 AWG thru 2 AWG fully annealed stranded bare
copper per ASTM B3
• Class M - 16 AWG
• Class K - 14 AWG thru 2 AWG
• Stranding per ASTM B8

Insulation:
MINIMUM AVG. MINIMUM AVG.
INSULATION
JACKET
NO. COND.
CATALOG OF SIZE COND. THICKNESS THICKNESS
NUMBER COND. (AWG) STRAND INCHES mm INCHES mm

NOMINAL
CABLE O.D.
INCHES
mm

COPPER
WEIGHT

NET WEIGHT

LBS/
LBS/
1000 FT kg/km 1000 FT kg/km

16 AWG CONDUCTORS
245310* 4
419630* 4
¥
245320* 8
404010* 8
¥
245330* 12
404020* 12

16
16
16
16
16
16

65/34
65/34
65/34
65/34
65/34
65/34

0.030
0.030
0.030
0.030
0.030
0.030

245340* 4
404030* 4
¥
245350* 8
404090* 8
¥
245360* 12
403990* 12

14
14
14
14
14
14

41/30
41/30
41/30
41/30
41/30
41/30

0.030
0.030
0.030
0.030
0.030
0.030

245370*
404040*
¥
245380*
238800*
¥
365680*
404080*
¥
245390*
404330*

4
4
5
5
7
7
8
8

12
12
12
12
12
12
12
12

65/30
65/30
65/30
65/30
65/30
65/30
65/30
65/30

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

245400*
404000*

4
4

10
10

¥

0.76
0.76
0.76
0.76
0.76
0.76

0.035
0.035
0.035
0.035
0.035
0.035

0.89
0.89
0.89
0.89
0.89
0.89

0.200 x 0.580
0.200 x 0.580
0.200 x 1.110
0.200 x 1.110
0.200 x 1.605
0.200 x 1.605

5.1 x 14.73
5.1 x 14.73
5.1 x 28.20
5.1 x 28.20
5.1 x 40.77
5.1 x 40.77

31.92
31.92
63.84
63.84
95.76
95.76

47.05
47.05
95.00
95.00
142.50
142.50

91
91
173
173
253
253

135
135
257
257
377
377

5.33 x 18.54
5.33 x 18.54
5.33 x 29.85
5.33 x 29.85
5.33 x 43.18
5.33 x 43.18

51.52
51.52
103.04
103.04
154.56
154.56

76.67
76.67
153.33
153.33
230.00
230.00

116
116
224
224
330
330

173
173
333
333
491
491

83.04
83.04
103.80
103.80
145.32
145.32
166.08
166.08

123.57
123.57
154.47
154.47
216.25
216.25
247.14
247.14

160
160
195
195
271
271
307
307

238
238
290
290
403
403
457
457

105/30 0.030 0.76 0.045 1.14 0.270 x 0.880 6.86 x 22.35 132.32 196.91
105/30 0.030 0.76 0.045 1.14 0.270 x 0.880 6.86 x 22.35 132.32 196.91

241
241

359
359

405
405

603
603

14 AWG CONDUCTORS
¥

0.76
0.76
0.76
0.76
0.76
0.76

0.035
0.035
0.035
0.035
0.035
0.035

0.89
0.89
0.89
0.89
0.89
0.89

0.210 x 0.710
0.210 x 0.710
0.210 x 1.175
0.210 x 1.175
0.210 x 1.700
0.210 x 1.700

12 AWG CONDUCTORS
¥

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.035
0.035
0.035
0.035
0.035
0.035
0.035
0.035

0.89
0.89
0.89
0.89
0.89
0.89
0.89
0.89

0.230 x 0.710
0.230 x 0.710
0.230 x 0.865
0.230 x 0.865
0.230 x 1.340
0.230 x 1.340
0.230 x 1.650
0.230 x 1.650

5.84 x 18.54
5.84 x 18.54
5.84 x 21.97
5.84 x 21.97
5.84 x 34.04
5.84 x 34.04
5.84 x 41.91
5.84 x 41.91

10 AWG CONDUCTORS
¥

8 AWG CONDUCTORS
¥

245410*
406320*

4
4

8
8

168/30 0.045 1.14 0.045 1.14
168/30 0.045 1.14 0.045 1.14

245420*
404050*
¥
332010*
434680*

4
4
5
5

6
6
6
6

266/30
266/30
266/30
266/30

495.36
495.36
619.20
619.20

612
612
747
747

911
911
1112
1112

245440*
404060*

4
4

4
4

420/30 0.060 1.52 0.045 1.14 0.490 x 1.690 12.45 x 42.93 560.00 833.34
420/30 0.060 1.52 0.045 1.14 0.490 x 1.690 12.45 x 42.93 560.00 833.34

750
750

1116
1116

245450*
404070*

4
4

2
2

665/30 0.060 1.52 0.045 1.14 0.560 x 1.955 14.23 x 49.66 852.00 1267.86 1273
665/30 0.060 1.52 0.045 1.14 0.560 x 1.955 14.23 x 49.66 852.00 1267.86 1273

1894
1894

0.365 x 1.190 9.27 x 30.23 212.40 316.07
0.365 x 1.190 9.27 x 30.23 212.40 316.07

• Flame-retardant Polyvinyl Chloride (PVC)
• Color-coded per ICEA Method 1, Table E-2 (does
not include white or green). All with alpha-numeric
designations

Jacket:

• Flame-retardant Polyvinyl Chloride (PVC),
yellow or black

Print:

• E-24573 PVC T-XXXXX 105˚C 600 V VW-1 (UL)FESTOON CABLE OUTDOOR XX/C XX/AWG-CSA
LL9755 105˚C 600 V FT1

Applications:

• Cranes and hoists
• Festooning systems
• Track systems
• Robots
• Conveyors
• Telescoping jetways

Features:

• Rated at 105˚C
• Designed for continuous extreme flexing
applications
• Anti-coiling in festoon applications
• Small bending radii
• Flat construction allows for stacking
• Oil- and chemical-resistant
• Indoor or outdoor use
• Meets cold bend test at -55˚C

Compliances:

Industry Compliances:
	 • UL listed/CSA certified flat festoon cable
Flame Test Compliances:
	 • UL VW-1/CSA FT1
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

6 AWG CONDUCTORS
¥

0.060
0.060
0.060
0.060

1.52
1.52
1.52
1.52

0.045
0.045
0.045
0.045

1.14
1.14
1.14
1.14

0.430 x 1.450
0.430 x 1.450
0.430 x 1.735
0.430 x 1.735

10.92 x 36.83
10.92 x 36.83
10.92 x 44.07
10.92 x 44.07

332.88
332.88
416.10
416.10

4 AWG CONDUCTORS
¥

2 AWG CONDUCTORS
¥

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¥ Indicates black jacketed cables.

Phone: 888-593-3355
www.generalcable.com

Date of Issue 06/13
Section 4		

Industrial Cables

600 V Multi-Conductor Control and Power Cables
SPECIFICATION NO.

PRODUCT DESCRIPTION

REVISION DATE

4050†

CHTC®

XLPE/XL-CPE, Control, Unshielded
600 V, UL Type TC—E-2 Color Code

Mar. 2012

4075†

CHTC®

XLPE/XL-CPE, Control, Unshielded
600 V, UL Type TC—E-1 Color Code

Mar. 2012

4100†

CHTC®

XLPE/XL-CPE, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER—Method 4 Color Code

Mar. 2012

4150

EHTC®

FR-EPR/XL-CPE, Control, Unshielded
600 V, UL Type TC (18 AWG/16 AWG)—E-2 Color Code

Mar. 2012

4200

EHTC®

FR-EPR/XL-CPE, Control, Unshielded
600 V, UL Type TC (14 AWG—10 AWG)—E-2 Color Code

Mar. 2012

4250

EHTC®

FR-EPR/XL-CPE, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER—Method 4 Color Code

Mar. 2012

4300†

FREP®

FR-EPR/CPE, Control, Unshielded
600 V, UL Type TC-ER—E-2 Color Code

Mar. 2012

4310†

FREP®

FR-EPR/CPE, Control, Unshielded
600 V, UL Type TC-ER—E-1 Color Code

Mar. 2012

4325†

FREP®

FR-EPR/CPE, Control, Shielded
600 V, UL Type TC-ER, Overall Shielded—E-2 Color Code

Mar. 2012

4350†

FREP®

FR-EPR/CPE, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER—Method 4 Color Code

Aug. 2012

4400

Arctic-Flex® XLPE/Arctic-PVC, Control, Unshielded
600 V, UL Type TC-ER, CSA Type RW90 XLPE, CSA Type TC

Mar. 2012

4450

Arctic-Flex® XLPE/Arctic-PVC, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER, CSA Type RW90 XLPE, CSA Type TC

Mar. 2012

4460

CCTC™

FR-XLPE/CPE, Control, Shielded
600 V, UL Type TC-ER—E-1 Color Code

Jun. 2012

4480

CCTC™

FR-XLPE/CPE, Low-Voltage Power, Shielded
600 V, UL Type TC-ER—Method 4 Color Code

Jun. 2012

4500†

CVTC®

XLPE/PVC, Control, Unshielded
600 V, UL Type TC-ER—E-2 Color Code

Mar. 2012

4550†

CVTC®

XLPE/PVC, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER—Method 4 Color Code

Mar. 2012

4575

CVTC® VFD

XLPE/PVC, Low-Voltage Power, Shielded
2000 V, UL Type TC-ER—Method 4 Color Code

Mar. 2012

4580†

CVTC® VFD

XLPE/PVC, Low-Voltage Power, Copper Tape Shielded
2000 V, UL Type TC-ER—Method 4 Color Code

Mar. 2012

†Indicates

these products are stocked by General Cable

Phone: 888-593-3355
www.generalcable.com

		
Industrial Cables		

Date of Issue 06/13
Section 4

600 V Multi-Conductor Control and Power Cables
SPECIFICATION NO.

PRODUCT DESCRIPTION

4600†

VNTC®

PVC/Nylon/PVC, Control, Unshielded
600 V, UL Type TC-ER (18 AWG/16 AWG)—E-2 Color Code

Mar. 2012

4650†

VNTC®

PVC/Nylon/PVC, Control, Unshielded
600 V, UL Type TC-ER (14 AWG—10 AWG)—E-2 Color Code

Mar. 2012

4700†

VNTC®

PVC/Nylon/PVC, Control, Shielded
600 V, UL Type TC-ER, Overall Shielded—E-2 Color Code

Mar. 2012

4750†

VNTC®

PVC/Nylon/PVC, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER—Method 4 Color Code

Mar. 2012

4775†

TC-Flex™

18 AWG (1,0 mm²)—16 AWG (1,5 mm²)
UL Type WTTC 1000 V or Type TC-ER 600 V or Type MTW and c(UL) CIC/TC
600 V FT4 or CSA AWM 90°C 1000 V

Jun. 2013

4780†

TC-Flex™

14 AWG (2,5 mm²)–10 AWG (6,0 mm²)
UL Type WTTC 1000 V or Type TC-ER 600 V or Type MTW and c(UL) CIC/TC
600 V FT4 or CSA AWM 90°C 1000 V

Jun. 2013

4785†

TC-Flex™

18 AWG (1,0 mm²)—16 AWG (1,5 mm²)
UL Type WTTC 1000 V or Type TC-ER 600 V or Type MTW and c(UL) CIC/TC
600 V FT4 or CSA AWM 90°C 1000 V

Jun. 2013

4790†

TC-Flex™

14 AWG (2,5 mm²)—4 AWG (35,0 mm²)
UL Type WTTC 1000 V or Type TC-ER 600 V or Type MTW and c(UL) CIC/TC
600 V FT4 or CSA AWM 90°C 1000 V

Jun. 2013

4800

20/10

PE/PVC/PVC, Control, Unshielded
600 V (18 AWG/16 AWG)—E-1 Color Code

Jul. 2010

4850

20/10

PE/PVC/PVC, Control, Unshielded
600 V (14 AWG—10 AWG)—E-1 Color Code

Jul. 2010

4900†

GenFree®

XLPE/LSZH, Control
600 V, UL Type TC-LS-ER—E-2 Color Code

Oct. 2012

4925

GenFree®

XLPE/LSZH, Control, Shielded
600 V, UL Type TC-LS-ER, Overall Shielded—E-2 Color Code

Oct. 2012

4950†

GenFree®

XLPE/LSZH, Low-Voltage Power, Unshielded
600 V, UL Type TC-LS-ER—Method 4 Color Code

Oct. 2012

†Indicates

REVISION DATE

these products are stocked by General Cable

Phone: 888-593-3355
www.generalcable.com

SPEC 4050

March, 2012

CHTC

®

XLPE/XL-CPE, Control, Unshielded
600 V, UL Type TC—E-2 Color Code
Product Construction:
Conductor:

• 16 AWG thru 10 AWG fully annealed stranded
tinned copper per ASTM B33
• Class B stranding per ASTM B8

Insulation:

• Flame-retardant Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1, Table E-2 plus
alpha-numeric printed numbers (does not include
white or green)

Jacket:

• Lead-free Cross-linked Chlorinated Polyethylene
(XL-CPE)

Print

• GENERAL CABLE ® (PLANT OF MFG) CHTC®
XX/C XXAWG CU/XLP/XL-CPE (UL) TYPE TC
XHHW-2 CDRS DIR BUR SUN RES OIL RES I & II
600 V DAY/MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

Options:

• 2 kV version
• Bare copper conductor
• Class C stranding
• E-1 Color Code—see Spec 4075
• Overall shielded multi-conductor
• Ethylene Propylene Rubber (EPR)
insulation—see EHTC® Spec 4200
• Thermoplastic Low-Smoke, Zero-Halogen
(LSZH) jacket
• Flame-retardant Polyvinyl Chloride (PVC)
jacket—see CVTC® Spec 4500
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Div. 2 industrial
hazardous locations per NEC Article 501 and
Class 1 circuits per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties
• Excellent moisture resistance
• Excellent resistance to crush, compression cuts
and heat deformation
• Excellent flame resistance
• Oil-resistant jacket
• “Heavy Duty” rating per ICEA standards
• Sunlight- and weather-resistant
• Excellent low temperature cold bend
characteristics
• Meets cold bend test at -35˚C

Compliances:

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

16 AWG MULTI-CONDUCTORS
241420
312500
312510
312520
241430
241440

2
3
4
5
7
9

16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

223650* 2 Flat
2
272270
3
223790
4
223780
5
223770
7
223750
9
223760
12
223640
223670* 19
232850* 37

14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

260730* 2 Flat
2
272260
3
223910
4
223930
5
223920
7
224080
9
224070
12
224090
265940* 19
347050* 37

12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

361350* 2 Flat
2
355210
3
224100
4
224110
5
224120*
7
224130*
9
347060*
12
347070*

10
10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060

1.14
1.14
1.14
1.14
1.14
1.52

0.340 8.64
0.360 9.14
0.390 9.91
0.420 10.67
0.460 11.68
0.565 14.35

17
25
33
41
58
74

25
37
49
61
86
110

61
73
91
110
141
199

91
109
135
164
210
296

26
26
39
53
66
92
118
158
250
490

39
39
59
78
98
137
176
235
372
730

68 101
75
112
95
141
118
176
143
213
179 266
249 371
317 472
467 695
899 1338

50
74
51
76
64
95
85 126
106 158
168 251
191 285
255 380
403 600
741 1103

85 126
98 146
127 189
160 238
194 289
264 393
345
513
435 647
690 1027
1393 2073

14 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03

.230 x .365 5.84 x 9.27

0.370
0.390
0.425
0.465
0.505
0.620
0.700
0.815
1.130

9.40
9.91
10.80
11.81
12.83
15.75
17.78
20.70
28.70

12 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03

.250 x .400 6.35 x 10.16

0.410
0.435
0.475
0.520
0.595
0.695
0.780
0.955
1.265

10.41
11.05
12.07
13.21
15.11
17.65
19.81
24.26
32.13

10 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03

.270 x .445 6.86 x 11.30

0.455
0.485
0.560
0.615
0.670
0.765
0.905

5.26
12.32
14.22
15.62
17.02
19.43
22.99

66
67
100
134
167
234
302
404

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

98
100
150
199
249
349
449
601

117
126
176
240
291
376
456
636

174
188
262
357
433
560
679
946

SPEC 4075

March, 2012

CHTC

®

XLPE/XL-CPE, Control, Unshielded
600 V, UL Type TC—E-1 Color Code
Product Construction:
Conductor:

• 14 AWG thru 10 AWG fully annealed stranded
tinned copper per ASTM B33
• Class B stranding per ASTM B8

Insulation:

• Flame-retardant Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1, Table E-1

Jacket:
COPPER
WEIGHT

CATALOG
NUMBER

MINIMUM AVG. MINIMUM AVG.
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

14 AWG MULTI-CONDUCTORS
256260* 2 Flat
2
330580
3
244160
4
239640
5
239700
7
237500
9
239660
12
252400
19
252410*
383980* 25
383990* 30
384000* 37

14
14
14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

.230 x .365 5.84 x 9.27

0.370
0.390
0.425
0.465
0.505
0.620
0.700
0.815
1.000
1.050
1.130

9.40
9.91
10.80
11.81
12.83
15.75
17.78
20.70
25.40
26.67
28.70

26
26
39
53
66
92
118
158
250
330
398
490

39
39
59
78
98
137
176
235
372
491
592
730

68 101
75
112
95
141
118
176
143
213
179 266
249 371
317 472
467 695
632 941
731 1088
899 1338

42
42
64
85
106
168
191
255
403
515
618
741

63
85
63
98
95 127
126 160
158 194
251 264
285 345
380 435
600 690
767 858
920 997
1103 1393

126
146
189
238
289
393
513
647
1027
1277
1484
2073

66
67
100
134
167
234
302
404

98
100
150
199
249
349
449
601

174
188
262
357
433
560
679
946

12 AWG MULTI-CONDUCTORS
233320* 2 Flat
2
239670
3
233330
4
239680
5
239650
7
243530
9
239620
12
252360
252230* 19
384010* 25
384020* 30
384030* 37

12
12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

384040* 2 Flat
2
243540
3
239630
4
233310
5
262680*
7
375010*
9
235680*
12
375470*

10
10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

.250 x .400 6.35 x 10.16

0.410
0.435
0.475
0.520
0.595
0.695
0.780
0.955
1.095
1.175
1.265

10.41
11.05
12.07
13.21
15.11
17.65
19.81
24.26
27.81
29.85
32.13

10 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03

.270 x .445 6.86 x 11.30

0.455
0.485
0.560
0.615
0.670
0.765
0.905

5.26
12.32
14.22
15.62
17.02
19.43
22.99

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

117
126
176
240
291
376
456
636

• Lead-free Cross-linked Chlorinated Polyethylene
(XL-CPE)

Print

• GENERAL CABLE ® (PLANT OF MFG) CHTC®
XX/C XXAWG CU/XLP/XL-CPE (UL) TYPE TC
XHHW-2 CDRS DIR BUR SUN RES OIL RES I & II
600 V DAY/MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

Options:

• 2 kV version
• Bare copper conductor
• Class C stranding
• E-2 Color Code—see Spec 4050
• Overall shielded multi-conductor
• Ethylene Propylene Rubber (EPR)
insulation—see EHTC Spec 4200
• Thermoplastic Low-Smoke, Zero-Halogen (LSZH)
jacket
• Flame-retardant Polyvinyl Chloride (PVC)
jacket—see CVTC® Spec 4500
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Div. 2 industrial
hazardous locations per NEC Article 501 and
Class 1 circuits per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties
• Excellent moisture resistance
• Excellent resistance to crush, compression cuts
and heat deformation
• Excellent flame resistance
• Oil-resistant jacket
• “Heavy Duty” rating per ICEA standards
• Sunlight- and weather-resistant
• Excellent low temperature cold bend
characteristics
• Meets cold bend test at -35˚C

Compliances:

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 4100

March, 2012

CHTC

®

XLPE/XL-CPE, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER1—Method 4 Color Code
Product Construction:
Conductor:

•	14 AWG thru 500 kcmil tinned, annealed
copper per ASTM B33
•	Class B stranding per ASTM B8

Insulation:

•	Flame-retardant Cross-linked Polyethylene (XLPE)
•	Color-coded per ICEA Method 4; individual
conductors colored black with conductor number
surface printed in contrasting ink

Options (cont’d.):

•	Uninsulated tinned annealed copper
per ASTM B3
•	Class B stranding per ASTM B8

Print:

•	GENERAL CABLE ® (PLANT OF MFG) CHTC®
XX/C XXAWG WITH GRND CU/XLP/XL-CPE (UL)
TYPE TC-ER XHHW-2 CDRS DIR BUR SUN RES
600 V MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC-ER for 2 AWG and larger,
UL File # E57179
	 • UL 1581
	 • ICEA S-95-658/NEMA WC70
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Features:

•	Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
•	Excellent physical, thermal and electrical
properties
•	Excellent moisture resistance
•	Excellent resistance to crush, compression cuts
and heat deformation
•	Excellent flame resistance
•	Excellent low temperature cold bend
characteristics
•	“Heavy duty” rating per ICEA standards
•	Sunlight- and weather-resistant
•	Oil-resistant jacket

Options:

•	Bare copper conductor
•	Class C stranding
•	2 kV version
•	E-1 or E-2 Color Code
•	Overall shielded multi-conductor
•	Insulated ground conductor
•	Flame-retardant Ethylene Propylene Rubber (EPR)
insulation—see EHTC® Spec 4250

NO. OF
COND.

Compliances:

•	In free air, raceways or direct burial
•	In wet or dry locations
•	Permitted for Exposed Run (ER) use in
accordance with NEC for 2 AWG and larger
•	Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

• Lead-free Cross-linked Chlorinated Polyethylene
(XL-CPE)

CATALOG
NUMBER

•	Meets cold bend test at -35˚C
•	Meets the crush and impact requirements of Type
MC cable for 2 AWG and larger

Applications:

Jacket:

COND.
SIZE
(AWG/
kcmil)

Features (cont’d.):

•	Thermoplastic Low-Smoke, Zero-Halogen (LSZH)
jacket
• Other constructions available upon request

Ground:

COND.
STRAND

GROUND
WIRE SIZE
(AWG)

MINIMUM AVG.
INSULATION
THICKNESS
INCHES

mm

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

MINIMUM AVG.
JACKET THICKNESS
INCHES

mm

NOMINAL
CABLE O.D.
INCHES

COPPER
WEIGHT

NET WEIGHT

mm

LBS/
1000 FT

kg/km

LBS/
1000 FT

kg/km

10.80
12.07
14.22
16.13
17.91
18.29
20.83
21.84
24.13
25.40
28.45
28.45
31.37
30.86
33.78
33.27
37.59
36.07
39.88
39.12
44.83
44.20
49.15
51.05
55.37
58.55
64.90

53
85
134
190
242
301
384
448
578
716
919
872
1136
1081
1413
1341
1760
1717
2245
2132
2796
2494
3282
3477
4577
4938
6509

78
126
199
283
360
448
571
667
861
1066
1368
1298
1691
1609
2103
1996
2619
2555
3341
3173
4161
3712
4884
5174
6811
7349
9647

118
160
240
325
405
481
600
667
905
1024
1295
1199
1704
1463
1830
1810
2326
2437
3123
2659
3909
3196
4571
4423
6068
6097
7905

176
238
357
483
603
716
893
992
1347
1524
1927
1784
2536
2177
2723
2694
3462
3627
4648
3957
5817
4756
6803
6582
9030
9074
11764

14 AWG - 500 kcmil MULTI-CONDUCTORS
383790*
309340*
282570*
282580
282590*
282600
282610*
282620
282630*
282640
282650*
366070*
366080*
282660*
338860*
282670*
292410*
366090*
366100*
282680*
338880*
338890*
338900*
282690*
338910*
282710*
331150*

3
3
3
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4

14
12
10
8
8
6
6
4
4
2
2
1
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
250
250
350
350
500
500

7/.0242
7/.0305
7/.0385
7/.0486
7/.0486
7/.0612
7/.0612
7/.0772
7/.0772
7/.0974
7/.0974
19/.0664
19/.0664
19/.0745
19/.0745
19/.0837
19/.0837
19/.0940
19/.0940
19/.1055
19/.1055
37/.0822
37/.0822
37/.0973
37/.0973
37/.1162
37/.1162

14
12
10
10
10
8
8
8
8
6
6
6
6
6
6
6
6
4
4
4
4
4
4
3
3
2
2

0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.065
0.065
0.065

0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.65
1.65
1.65
1.65
1.65
1.65

0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110
0.110
0.110
0.110

1.14
1.14
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79
2.79
2.79
2.79

0.425
0.475
0.526
0.635
0.705
0.720
0.820
0.860
0.950
1.000
1.120
1.120
1.235
1.215
1.330
1.310
1.480
1.420
1.570
1.540
1.765
1.740
1.935
2.010
2.180
2.305
2.555

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 2 AWG and larger defined by NEC.

Phone: 888-593-3355
www.generalcable.com

SPEC 4150

March, 2012

EHTC

®

FR-EPR/XL-CPE, Control, Unshielded
600 V, UL Type TC (18 AWG/16 AWG)—E-2 Color Code
Product Construction:
Conductor:

• 18 AWG and 16 AWG tinned, annealed copper per
ASTM B33
• Class B stranding per ASTM B8

Insulation:

• Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II
• Color-coded per ICEA Method 1, Table E-2
(does not include white or green)

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

18 AWG MULTI-CONDUCTORS
366190* 2 Flat
343330* 2
343340* 3
343350* 4
343360* 5
343370* 7
343380* 9
343390* 10
343400* 12
343410* 15
343420* 19
343430* 25
343440* 30
343450* 37

18
18
18
18
18
18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

366200* 2 Flat
343460* 2
343470* 3
343480* 4
343490* 5
343500* 7
343510* 9
343520* 10
343530* 12
343540* 15
343550* 19
343560* 25
343570* 30
343580* 37

16
16
16
16
16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025

0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.060

1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
1.52

10
7.49 10
7.88 15
8.64 20
9.27 26
10.03 36
11.56 46
12.32 51
12.95 61
14.73 77
15.88 97
18.29 128
19.56 154
21.08 189

.192 x .290 4.88 x 7.37

0.295
0.310
0.340
0.365
0.395
0.455
0.485
0.510
0.580
0.625
0.720
0.770
0.830

15
15
23
30
38
53
69
76
91
114
144
190
229
281

37
45
55
67
79
97
123
137
153
202
243
301
345
414

55
67
82
100
118
144
183
204
228
301
362
448
513
616

24
24
36
48
60
84
108
119
144
180
228
299
360
443

46
55
69
85
102
127
162
197
221
270
327
424
508
609

68
82
130
126
152
189
241
293
329
402
487
631
756
906

16 AWG MULTI-CONDUCTORS
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025

0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
1.52
2.03
2.03

.204 x .314 5.18 x 7.98

0.320
0.340
0.365
0.400
0.430
0.500
0.565
0.590
0.640
0.690
0.795
0.890
0.955

8.13
8.67
9.27
10.20
10.90
12.70
14.40
14.97
16.26
17.53
20.19
22.61
24.26

16
16
24
32
40
56
72
80
97
121
153
201
242
298

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Jacket:

• Lead-free Cross-linked Chlorinated Polyethylene
(XL-CPE)

Print

• GENERAL CABLE ® (PLANT OF MFG) EHTC®
XX/C XXAWG EPR/XL-CPE (UL) TYPE TC 90˚
WET OR DRY CDRS BUR SUN RES 600 V DAY/
MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE
MARK

Options:

• 2 kV version
• Bare copper conductors
• Class C stranding
• Insulated or uninsulated ground conductors
• Overall shielded multi-conductors
• Duralox® aluminum interlocked armor
• E-1 Color Code
• Flame-retardant Polyvinyl Chloride (PVC) jacket
• Thermoplastic Low-Smoke, Zero-Halogen (LSZH)
jacket
• Flame-retardant thermoplastic Chlorinated
Polyethylene (CPE)—See FREP ® Spec 4300
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• At temperature as low as -35˚C
• In Class I, Division 2 industrial hazardous locations
per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties
• Excellent moisture resistance
• Excellent resistance to crush, compression cuts
and heat deformation
• Excellent flame resistance
• Excellent low temperature cold bend
characteristics
• Good abrasion resistance
• Low moisture absorption characteristics
• “Heavy duty” rated per ICEA standards
• Meets cold bend test at -35˚C

Compliances:

Industry Compliances:
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 4200

March, 2012

EHTC

®

FR-EPR/XL-CPE, Control, Unshielded
600 V, UL Type TC (14 AWG—10 AWG)—E-2 Color Code
Product Construction:
Conductor:

• 14 AWG thru 10 AWG tinned, annealed copper per
ASTM B33
• Class B stranding per ASTM B8

Insulation:

• Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II
• Color-coded per ICEA Method 1, Table E-2 (does
not include white or green)

Jacket:

• Lead-free Cross-linked Chlorinated Polyethylene
(XL-CPE)

Print

• GENERAL CABLE ® (PLANT OF MFG) EHTC®
XX/C XXAWG EPR/XL-CPE (UL) TYPE TC XHHW2 CDRS BUR SUN RES 600 V DAY/MONTH/YEAR
OF MFG SEQUENTIAL FOOTAGE MARK

Options:

• 2 kV version
• Bare copper conductors
• Class C stranding
• Insulated or uninsulated ground conductors
• Overall shielded multi-conductors
• Duralox® aluminum interlocked armor
• E-1 Color Code
• Flame-retardant Polyvinyl Chloride (PVC) jacket
• Thermoplastic Low-Smoke, Zero-Halogen (LSZH)
jacket
• Flame-retardant thermoplastic Chlorinated
Polyethylene (CPE)—see FREP ® Spec 4300
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• At temperature as low as -35˚C
• In Class I, Division 2 industrial hazardous locations
per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties
• Excellent moisture resistance
• Excellent resistance to crush, compression cuts
and heat deformation
• Excellent flame resistance
• Excellent low temperature cold bend
characteristics
• Good abrasion resistance
• Low moisture absorption characteristics
• “Heavy duty” rated per ICEA standards
• Meets cold bend test at -35˚C

Compliances:

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

14 AWG MULTI-CONDUCTORS
262130* 2 Flat
2
343590*
3
262140*
4
248240*
5
262150*
7
262160*
9
343600*
248290* 12
343630* 19
262190* 25
343640* 30
343650* 37

14
14
14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

343660*
343670*
343680*
343690*
262200*
343700*
343710*
343730*
343750*
343760*
343770*
343780*

2 Flat
2
3
4
5
7
9
12
19
25
30
37

12
12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

343790* 2 Flat
2
343800*
3
343810*
4
264990*
5
343820*
7
343830*
9
343840*
343860* 12

10
10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

.230 x .365 5.84 x 9.27

0.370
0.390
0.425
0.465
0.505
0.620
0.700
0.815
1.000
1.050
1.130

9.40
9.91
10.80
11.81
12.83
15.75
17.78
20.71
25.40
26.70
28.71

26
26
39
53
66
92
118
158
250
330
398
490

38
39
59
78
98
137
176
235
372
491
592
729

68
76
97
120
145
183
254
323
477
645
746
919

101
113
144
179
216
272
378
481
710
960
1110
1368

50
51
64
85
106
168
191
255
403
515
618
741

76
88
131
76
99
147
95 129 192
127 163 243
158 198 295
250 269 400
285 351 522
380 443 659
600 703 1046
767 875 1302
920 1017 1513
1103 1421 2115

66
67
100
134
167
234
302
404

98
100
150
199
249
349
449
601

12 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

.250 x .400 6.35 x 10.16

0.410
0.435
0.475
0.520
0.595
0.695
0.780
0.955
1.115
1.150
1.240

10.41
11.05
12.07
13.21
15.11
17.65
19.81
24.26
28.32
29.21
31.50

10 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03

.270 x .445 6.86 x 11.30

0.455 11.6
0.485 12.3
0.560 14.2
0.615 15.6
0.670 17.0
0.765 19.4
0.905 23.0

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

119
134
178
243
295
382
492
662

177
199
265
362
439
568
732
985

SPEC 4250

March, 2012

EHTC

®

FR-EPR/XL-CPE, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER1—Method 4 Color Code
Features (cont’d.):

Product Construction:
Conductors:

Options:

•	2 kV version
•	Bare copper conductors
•	Insulated ground conductor
•	Cross-linked Polyethylene (XLPE) insulation
•	Flame-retardant Polyvinyl Chloride (PVC) jacket
•	Thermoplastic Low-Smoke, Zero-Halogen
(LSZH) jacket
•	Flame-retardant Thermoplastic Chlorinated
Polyethylene (CPE)—see FREP ® Spec 4350
•	Class C stranding
•	E-1 or E-2 Color Code
• Other constructions available upon request

•	14 AWG thru 500 kcmil tinned, annealed copper
per ASTM B33
•	Class B stranding per ASTM B8

Insulation:

•	Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II
•	Color-coded per ICEA Method 4; individual
conductors colored black with conductor number
surface printed in contrasting ink

Ground:

Compliances:

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC-ER for 2 AWG & larger,
UL File # E57179
	 • UL 1581
	 • ICEA S-95-658/NEMA WC70
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Applications:

•	Uninsulated tinned annealed copper per ASTM B3
•	Class B stranding per ASTM B8

•	In free air, raceways or direct burial
•	In wet or dry locations
•	Permitted for Exposed Run (ER) use in
accordance with NEC for 2 AWG and larger
•	In Class I, Division 2 industrial hazardous locations
per NEC

Jacket:

• Lead-free Cross-linked Chlorinated Polyethylene
(XL-CPE)

Print:

Features:

•	GENERAL CABLE ® (PLANT OF MFG) EHTC®
XX/C XXAWG WITH GRND EPR/XL-CPE (UL)
TYPE TC-ER XHHW-2 CDRS DIR BUR SUN RES
600 V DAY/MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

CATALOG
NUMBER

•	UL 44 Type XHHW-2, VW-1, 600 V
•	Excellent physical, thermal and electrical
properties
•	Excellent resistance to moisture
•	Excellent resistance to crush, compression cuts
and heat deformation
•	Excellent flame resistance
•	“Heavy Duty” rated per ICEA standards
•	Excellent low temperature cold bend
characteristics
•	Meets cold bend test at -35˚C
•	Meets the crush and impact requirements of Type
MC cable for 2 AWG and larger

Packaging:

•	Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less

NO. OF
COND.

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

3
3
3
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4

14
12
10
8
8
6
6
4
4
2
2
1
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
250
250
350
350
500
500

7/.0242
7/.0305
7/.0385
7/.0486
7/.0486
7/.0612
7/.0612
7/.0772
7/.0772
7/.0974
7/.0974
19/.0664
19/.0664
19/.0740
19/.0740
19/.0837
19/.0837
19/.0940
19/.0940
19/.1055
19/.1055
37/.0822
37/.0822
37/.0973
37/.0973
37/.1162
37/.1162

GROUND
WIRE SIZE
(AWG)

MINIMUM AVG.
INSULATION
THICKNESS
INCHES

mm

•	Material cut to length and shipped on
non-returnable wood reels

MINIMUM AVG.
JACKET THICKNESS NOMINAL CABLE O.D.
INCHES

mm

INCHES

COPPER
WEIGHT

mm

LBS/
1000 FT

9.91
11.05
12.32
16.76
18.42
18.92
20.83
22.61
24.77
25.91
28.45
28.45
31.37
31.50
33.78
34.04
37.59
36.07
39.88
40.01
44.83
44.58
49.15
51.05
55.37
58.55
64.90

53
85
134
190
242
301
384
448
578
716
919
872
1136
1081
1413
1341
1760
1717
2245
2132
2796
2494
3282
3477
4577
4938
6509

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

78
126
199
283
360
448
571
667
860
1066
1368
1298
1691
1609
2103
1996
2619
2555
3341
3173
4161
3712
4884
5174
6811
7349
9687

118
160
240
223
421
481
600
702
882
1024
1295
1199
1704
1505
1830
1810
2326
2437
3123
2725
3909
3605
4571
4423
6068
6097
7905

176
238
357
332
627
716
893
1045
1313
1524
1927
1784
2536
2240
2723
2694
3462
3627
4648
4055
5817
5365
6803
6582
9030
9074
11764

14 AWG - 500 kcmil MULTI-CONDUCTORS
383800*
383810*
383820*
261000*
338670*
366210*
338680*
261010*
338690*
338700*
338710*
366220*
366230*
338720*
338730*
338740*
338750*
366240*
366250*
360990*
338770*
338780*
338790*
338800*
338310*
338820*
338830*

14
12
10
10
10
8
8
8
8
6
6
6
6
6
6
6
6
4
4
4
4
4
4
3
3
2
2

0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.065
0.065
0.065

0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.65
1.65
1.65
1.65
1.65
1.65

0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110
0.110
0.110
0.110

1.14
1.14
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79
2.79
2.79
2.79

0.390
0.435
0.485
0.660
0.725
0.745
0.820
0.890
0.975
1.020
1.120
1.120
1.235
1.240
1.330
1.340
1.480
1.420
1.570
1.575
1.765
1.755
1.935
2.010
2.180
2.305
2.555

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 2 AWG and larger defined by NEC.

Phone: 888-593-3355
www.generalcable.com

SPEC 4300

March, 2012

FREP

®

FR-EPR/CPE, Control, Unshielded
600 V, UL Type TC-ER1—E-2 Color Code
Product Construction:
Conductor:

• 14 AWG thru 10 AWG fully annealed stranded
tinned copper per ASTM B33
• Class B stranding per ASTM B8

Insulation:

• Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II
• Color-coded per ICEA Method 1, Table E-2 (does
not include white or green)

Jacket:

• Lead-free, flame-retardant thermoplastic
Chlorinated Polyethylene (CPE)

Print

• GENERAL CABLE ® (PLANT OF MFG) FREP ®
XX/C XXAWG EPR/CPE (UL) TYPE TC-ER
XHHW-2 CDRS 90°C WET OR DRY 600 V DIR
BUR SUN RES DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

Options:

• 2 kV version
• Bare copper conductor
• Class C stranding
• E-1 Color Code—see Spec 4310
• Overall shielded multi-conductor
• Flame-Retardant Cross-linked Polyethene
(FR-XLPE) insulation
• Thermoplastic Low-Smoke, Zero-Halogen (LSZH)
jacket
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors
•A
 pproved for direct burial
• Class I, Division 2 industrial hazardous locations
per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties
• Sunlight- and weather-resistant
• Excellent moisture resistance
• Excellent resistance to compression cuts and heat
deformation
• Low coefficient of friction for easy pulling
• Excellent flame resistance—burns to ash; does
not exhibit thermoplastic drip
• Excellent low temperature cold bend
characteristics
• Meets cold bend test at -40˚C
• Meets the crush and impact requirements of Type
MC cable for 3 or more conductors

Compliances:

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC-ER for 3 or more conductors,
UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

14 AWG MULTI-CONDUCTORS
279560 2 Flat
2
305320*
3
280180
4
280190
5
279870
7
280200
9
280210
12
279880
19
279580
25
279590
347080* 30
279600* 37

14
14
14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

279840 2 Flat
2
307690*
280170 3+ Grnd
3
280300
4
280310
5
280320
7
279890
9
280330
12
280340
19
279610
295400* 25
30
347100*
37
301870

12
12
12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

279570 2 Flat
2
305340*
279680 3+ Grnd
3
280410
4
279900
5
279620
7
279630
9
279640
12
279650

10
10
10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

.365 x .230 9.30 x 5.80

0.370
0.390
0.425
0.465
0.505
0.620
0.700
0.815
0.935
1.030
1.110

9.40
9.91
10.80
11.81
12.83
15.75
17.78
20.70
23.75
26.16
28.19

26
26
39
53
66
92
118
158
250
323
387
466

38
39
59
78
98
137
176
235
372
481
576
694

61
71
92
115
139
173
240
301
468
624
747
875

91
106
137
171
207
257
357
448
696
929
1112
1302

40
41
85
64
85
106
149
191
247
391
515
618
762

60
82 122
61
94 140
127 148 220
95 124 185
127 157 234
158 191 284
221 268 399
285 337 502
368 428 637
582 688 1024
767 854 1271
920 1002 1491
1134 1240 1845

64
65
134
100
134
167
234
295
402

95
97
199
150
199
249
349
440
598

12 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

.400 x .245 10.20 x 6.20

0.410
0.435
0.435
0.475
0.520
0.595
0.695
0.765
0.940
1.095
1.150
1.240

10.41
11.05
11.05
12.07
13.21
15.11
17.65
19.43
23.88
27.81
29.21
31.50

10 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03

.445 x .270 11.30 x 6.90

0.455
0.485
0.485
0.560
0.615
0.670
0.760
0.905

11.56
12.32
12.32
14.22
15.62
17.02
19.30
22.99

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

113
128
225
172
234
284
381
464
651

168
190
335
256
348
423
567
691
696

SPEC 4310

March, 2012

FREP

®

FR-EPR/CPE, Control, Unshielded
600 V, UL Type TC-ER1—E-1 Color Code
Product Construction:
Conductor:

• 14 AWG thru 10 AWG fully annealed stranded
tinned copper per ASTM B33
• Class B stranding per ASTM B8

Insulation:

• Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II
• Color-coded per ICEA Method 1, Table E-1
(includes white or green)

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

14 AWG MULTI-CONDUCTORS
280590 2 Flat
3
280230
4
280240
5
280250
7
280260
9
280270
12
280280
280290* 19
385350* 25
385360* 30
385370* 37

14
14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

279850 2 Flat
2
280350*
3
280360
4
279910
5
280370
7
280380
9
280390*
12
280400
383930* 19
383940* 25
383950* 30
330800* 37

12
12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

280600*
280420*
279920
279930
330990*
280430*
382880*
383970*

10
10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

.365 x .230 9.30 x 5.80

0.390
0.425
0.465
0.505
0.620
0.700
0.815
0.935
1.030
1.110

9.91
10.80
11.81
12.83
15.75
17.78
20.70
23.75
26.16
28.19

26
39
53
66
92
118
158
250
323
387
466

38
59
78
98
137
176
235
372
481
576
694

61
92
115
139
173
240
301
468
624
747
875

91
137
171
207
257
357
448
696
929
1112
1302

42
42
64
85
106
149
191
247
391
515
618
762

63
82 122
63
94 140
95 124 185
127 157 234
158 191 284
221 268 399
285 337 502
368 428 637
582 688 1024
767 854 1271
920 1002 1491
1134 1240 1845

64
65
100
134
167
234
295
402

95
97
150
199
249
349
440
598

12 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

.400 x .245 10.20 x 6.20

0.410
0.435
0.475
0.520
0.595
0.695
0.765
0.940
1.095
1.150
1.240

10.41
11.05
12.07
13.21
15.11
17.65
19.43
23.88
27.81
29.21
31.50

10 AWG MULTI-CONDUCTORS
2 Flat
2
3
4
5
7
9
12

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03

.445 x .270 11.30 x 6.90

0.455
0.485
0.560
0.615
0.670
0.760
0.950

11.56
12.32
14.22
15.62
17.02
19.30
22.99

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

113
128
172
234
284
381
464
651

168
190
256
348
423
567
691
969

Jacket:

• Lead-free, flame-retardant thermoplastic
Chlorinated Polyethylene (CPE)

Print

• GENERAL CABLE ® (PLANT OF MFG) FREP ®
XX/C XXAWG EPR/CPE (UL) TYPE TC-ER
XHHW-2 CDRS 90°C WET OR DRY 600 V DIR
BUR SUN RES DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

Options:

• 2 kV version
• Bare copper conductor
• Class C stranding
• E-2 Color Code—see Spec 4300
• Overall shielded multi-conductor
• Flame-Retardant Cross-linked Polyethene
(FR-XLPE) insulation
• Thermoplastic Low-Smoke, Zero-Halogen
(LSZH) jacket
• Other constructions available upon request

Applications:

• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors
•A
 pproved for direct burial
• Class I, Division 2 industrial hazardous locations
per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties
• Sunlight- and weather-resistant
• Excellent moisture resistance
• Excellent resistance to compression cuts and heat
deformation
• Low coefficient of friction for easy pulling
• Excellent flame resistance—burns to ash;
does not exhibit thermoplastic drip
• Excellent low temperature cold bend
characteristics
• Meets cold bend test at -40˚C
• Meets the crush and impact requirements of
Type MC cable for 3 or more conductors

Compliances:

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC-ER for 3 or more conductors,
UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 4325

March, 2012

FREP

®

FR-EPR/CPE, Control, Shielded
600 V, UL Type TC-ER1, Overall Shielded—E-2 Color Code
Product Construction:
Conductor:

• 16 AWG thru 10 AWG fully annealed stranded
tinned copper per ASTM B33
• Class B stranding per ASTM B8

Insulation:

• Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II
• Color-coded per ICEA Method 1, Table E-2
(does not include white or green)

Shield:

Overall shielded multi-conductor cable
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, flame-retardant thermoplastic
Chlorinated Polyethylene (CPE)

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

OVERALL SHIELDED MULTI-CONDUCTORS
16 AWG CONDUCTORS

Print

• GENERAL CABLE ® (PLANT OF MFG) SHIELDED
FREP ® XX/C XXAWG EPR/CPE (UL) TYPE TC-ER
XHHW-2 CDRS 90˚C WET OR DRY 600 V DIR
BUR SUN RES DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

280470
280490

2
3

Applications:

• In free air, raceway and direct burial
• In wet or dry locations
• Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors
•A
 pproved for direct burial
• Class I, Division 2 industrial hazardous locations
per NEC

280980*
354800*
305300*
354810*
354820*
367120*
354830*
305360*
367130*
367140*
367150*

2
3
4
5
7
9
12
19
25
30
37

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties
• Sunlight- and weather-resistant
• Excellent moisture resistance
• Excellent resistance to compression cuts and heat
deformation
• Low coefficient of friction for easy pulling
• Excellent flame resistance—burns to ash;
does not exhibit thermoplastic drip
• Excellent low temperature cold bend
characteristics
• Meets cold bend test at -40˚C
• Meets the crush and impact requirements of
Type MC cable for 3 conductors or more

Compliances:

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC-ER for 3 or more conductors,
UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

7/.0192 0.025 0.64 0.045 1.14 0.320 8.13
7/.0192 0.025 0.64 0.045 1.14 0.335 8.51

19
27

28
40

52
66

77
98

43
63
82
101
140
180
238
375
484
579
696

74
95
118
142
176
243
304
471
627
750
878

110
141
176
211
262
362
452
701
933
1116
1307

OVERALL SHIELDED MULTI-CONDUCTORS
14 AWG CONDUCTORS

Options:

• 2 kV version
• Bare copper conductor
• Class C stranding
• E-1 Color Code
• Unshielded multi-conductors
• Flame-Retardant Cross-linked Polyethene
(FR-XLPE) insulation
• Thermoplastic Low-Smoke, Zero-Halogen
(LSZH) jacket
• Other constructions available upon request

16
16

14
14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

0.375
0.395
0.430
0.470
0.510
0.625
0.705
0.820
0.940
1.035
1.115

9.53 29
10.03 42
10.92 55
11.94 68
12.95 94
15.88 121
17.91 160
20.83 252
25.53 325
26.29 389
28.32 468

OVERALL SHIELDED MULTI-CONDUCTORS
12 AWG CONDUCTORS
367160*
367170*
326650*
367180*
326660*
367190*
326640*
326670*
367200*
367210*
367220*

2
3
4
5
7
9
12
19
25
30
37

12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

0.415
0.440
0.480
0.525
0.600
0.700
0.770
0.945
1.100
1.155
1.245

10.45 43
11.18 66
12.19 87
13.34 108
15.24 151
17.78 193
19.56 249
24.00 393
27.94 517
29.80 620
31.62 764

64
97 144
98 127 189
129 160 238
162 194 289
225 271 403
287 340 506
371 431 641
585 691 1028
769 857 1275
923 1005 1496
1137 1243 1850

OVERALL SHIELDED MULTI-CONDUCTORS
10 AWG CONDUCTORS
311900*
367230*
311910*
367240*
367250*
367260*
367270*

2
3
4
5
7
9
12

10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.52
1.52
1.52
1.52
2.03

0.460
0.490
0.565
0.620
0.675
0.765
0.910

11.68
12.45
14.35
15.75
17.15
19.43
23.11

68
103
136
170
237
298
404

101
155
202
253
353
443
601

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

131
175
237
287
384
467
654

195
260
353
427
571
695
973

SPEC 4350

August, 2012

FREP

®

FR-EPR/CPE, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER1—Method 4 Color Code
Features (cont’d.):

Product Construction:
Conductor:

•	Excellent moisture resistance
•	Excellent resistance to crush, compression cuts
and heat deformation
•	Excellent low temperature cold bend
characteristics
•	Excellent flame resistance—burns to ash; does
not exhibit thermoplastic drip
•	Low coefficient of friction for easy pulling
•	Sunlight- and weather-resistant
•	Meets cold bend test at -40˚C

Options:

Insulation:

•	Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II
•	Color-coded per ICEA Method 4; individual
conductors colored black with conductor number
surface printed in contrasting ink

•	In free air, raceways or direct burial
•	In wet or dry locations
•	Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors
•	Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

•	Uninsulated tinned annealed copper per
ASTM B3
•	Class B stranding per ASTM B8

Jacket:

• Lead-free, flame-retardant thermoplastic
Chlorinated Polyethylene (CPE)

383830*
296450*
296440*
279660
279670
283210
300380
283200
295390
293600
295890
297730*
356740*
283220
294530*
284560
295360*
325700*
365750*
325110
346980*
300780
346990*
325120
347000*
298020
14407.546500*
14407.247000*
14407.547000*

3
3
3
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4

14
12
10
8
8
6
6
4
4
2
2
1
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
250
250
350
350
500
500
750
750

•	Material cut to length and shipped on
non-returnable wood reels

•	Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties

•	GENERAL CABLE ® (PLANT OF MFG) FREP ®
XX/C XXAWG WITH GRND EPR/CPE (UL) TYPE
TC-ER XHHW-2 CDRS 90˚C WET OR DRY 600 V
DIR BUR SUN RES DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

NO. OF
COND.

Packaging:

Features:

Print:

CATALOG
NUMBER

Industry Compliances:
	 •	UL 44 Type XHHW-2
	 •	UL 1277 Type TC-ER, UL File # E57179
	 •	UL 1581
	 •	ICEA S-95-658/NEMA WC70
Flame Test Compliances:
	 •	UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 •	IEEE 383
	 •	IEEE 1202
	 •	CSA FT4
	 •	ICEA T-29-520
Other Compliances:
	 •	EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 •	OSHA Acceptable

Applications:

Ground:

COND.
SIZE
(AWG/
kcmil)

Compliances:

•	2 kV version
•	Bare copper conductor
•	Class C stranding
•	E-1 or E-2 Color Code
•	Insulated ground conductors
•	Overall shielded multi-conductors
•	Flame-Retardant Cross-linked Polyethylene
(FR-XLPE) insulation
•	Flame-retardant, thermoplastic
Low-Smoke, Zero-Halogen (LSZH) jacket
•	Other constructions available upon request

•	14 AWG thru 750 kcmil tinned, annealed
copper per ASTM B33
•	Class B stranding per ASTM B8

COND.
STRAND
7/.0242
7/.0305
7/.0385
7/.0486
7/.0486
7/.0612
7/.0612
7/.0772
7/.0772
7/.0974
7/.0974
19/.0664
19/.0664
19/.0745
19/.0745
19/.0837
19/.0837
19/.0940
19/.0940
19/.1055
19/.1055
37/.0822
37/.0822
37/.0973
37/.0973
37/.1162
37/.1162
61/.1109
61/.1109

GROUND
WIRE SIZE
(AWG)

MINIMUM AVG.
INSULATION
THICKNESS
INCHES

mm

MINIMUM AVG.
JACKET THICKNESS NOMINAL CABLE O.D.
INCHES

mm

INCHES

COPPER
WEIGHT

mm

LBS/
1000 FT

9.91
11.05
12.32
16.64
18.29
18.80
20.07
22.35
24.13
25.65
27.69
28.45
31.37
31.12
33.78
33.02
36.58
36.07
39.88
39.12
45.47
44.70
48.64
49.78
5499
57.02
62.87
71.37
79.12

55
87
136
190
242
297
384
442
578
703
919
872
1136
1069
1413
1340
1760
1717
2245
2130
2796
2494
3282
3474
4577
4934
6509
7278
9712

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

82
129
202
283
360
442
571
658
861
1046
1368
1298
1691
1591
2103
1994
2619
2555
3341
3170
4161
3712
4884
5170
6811
7343
9687
10831
14453

118
160
237
314
393
456
561
642
822
979
1235
1021
1521
1439
1820
1720
2208
2176
2788
2614
3495
3184
4019
4187
5436
5847
7607
9145
11805

176
238
353
467
585
679
835
955
1223
1457
1838
1594
2264
2142
2709
2560
3286
3238
3405
3890
5201
4738
5981
6231
8090
8702
11321
13610
17569

14 AWG - 750 kcmil MULTI-CONDUCTORS
14
12
10
10
10
8
8
8
8
6
6
6
6
6
6
6
6
4
4
4
4
4
4
3
3
2
2
1
1

0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.065
0.065
0.065
0.080
0.080

0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.65
1.65
1.65
1.65
1.65
1.65
2.03
2.03

0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.140
0.140

1.14
1.14
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79
2.79
2.79
2.79
3.56
3.56

0.390
0.435
0.485
0.655
0.720
0.740
0.790
0.880
0.950
1.010
1.090
1.120
1.235
1.225
1.330
1.300
1.440
1.420
1.570
1.540
1.790
1.760
1.915
1.960
2.165
2.245
2.475
2.810
3.115

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

Phone: 888-593-3355
www.generalcable.com

SPEC 4400
March, 2012

Arctic-Flex

®

XLPE/Arctic-PVC, Control, Unshielded
600 V, UL Type TC-ER1, CSA Type RW90 XLPE, CSA Type TC
Product Construction:
Conductor:

•	14 AWG thru 10 AWG tinned, annealed copper
per ASTM B3
•	Class B stranding per ASTM B8	

Insulation:

•	Lead-free, flame-retardant Cross-linked
Polyethylene (XLPE)
•	Color-coded per CSA Standard C22.2 No. 38 as
follows:
Number of color coding of circuit conductors
No. of Cond.		
Color Code
	 2
		
blk, wht
	 3
		
blk, red, blu
	 4
		
blk, red, blu, wht
≥5		
all black
All conductors for all constructions are alphanumeric printed

Jacket:

•	Lead-free, flame-retardant, sunlight-resistant
Arctic-grade Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE ® (PLANT OF MFG) (UL) TYPE
TC-ER ARCTIC-FLEX® XX/C XXAWG FR-XLP/
PVC XHHW-2 CDRS 90C WET OR DRY SUN RES
DIR BUR 600 V - (CSA) TYPE RW90 XLPE -40C
TC FT4 600 V PLUS DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

Options:

•	Bare copper, class C stranding
•	Uninsulated ground (bonding) conductor
•	Optional color code as specified per CSA
standard C22.2 No. 38 for two to four conductor
cable
•	Non-UL 1000 volt CSA Type RW90 XLPE, CSA
Type TC
•	Other constructions available upon request

Applications:

•	Industrial lighting, control and signaling circuits
•	Approved for direct burial, Class I, Div. 2 industrial
hazardous locations per NEC for UL Type TC
cables. In Canada, protection may be required by
inspection authority per Canadian electrical code
•	Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors
•	Approved for cable in tray; industrial hazardous
locations; Class I, Zone 2; and Class II, Division 2
per CEC Rules 18-152 and 18-252 when used with
certified HL glands

Features:

•	Rated 90˚C wet or dry
•	Ripcord applied to all cables with jacket thickness
of 60 mils or less
•	Meets CSA cold impact test at -40˚C
•	Meets ICEA and CSA cold bend test at -60˚C
•	Meets the crush and impact requirements of Type
MC cable

Compliances:

Industry Compliances:
	 • ICEA S-73-532/NEMA WC57
	 •	UL 44 Type XHHW-2
	 •	UL 1277 Type TC-ER for 3 or more conductors,
UL File # E57179
	 •	UL 1581
	 •	CSA C22.2 No. 38 XLPE RW90
	 •	CSA C22.2 No. 230 Type TC
Flame Test Compliances:
	 •	UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 •	IEEE 383
	 •	CSA FT4
Other Compliances:
	 •	EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 •	OSHA Acceptable

Packaging:

•	Material cut to lengths and shipped on nonreturnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

14 AWG MULTI-CONDUCTORS
347340*
347350*
347360*
347370*
347380*
347390*
347400*
347410*
347420*
347430*
347440*

2
3
4
5
7
9
12
19
25
30
37

14
14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

347450*
347460*
347470*
347480*
347490*
347500*
347510*
347520*
347530*
347540*
347550*

2
3
4
5
7
9
12
19
25
30
37

12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

347560*
347570*
347580*
347590*
347600*
347610*
347620*

2
3
4
5
7
9
12

10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03

0.405
0.390
0.425
0.465
0.590
0.620
0.680
0.800
0.985
1.050
1.130

10.29
9.91
10.80
11.81
14.99
15.75
17.27
20.32
25.02
26.67
28.70

25
40
53
66
93
119
159
252
323
387
490

37
59
79
99
138
177
237
375
481
576
729

71
90
113
140
176
245
302
460
641
740
888

106
134
168
208
262
365
449
685
954
1101
1322

41
65
86
108
150
193
258
403
515
618
741

61
96 143
96 125 186
128 157 234
160 191 284
224 260 387
288 340 506
385 429 638
600 681 1013
767 885 1317
920 1005 1496
1103 1185 1764

67
101
135
167
234
295
402

100
150
200
249
349
440
598

12 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

0.410
0.435
0.475
0.520
0.595
0.695
0.780
0.930
1.095
1.150
1.240

10.41
11.05
12.07
13.21
15.11
17.65
19.81
23.62
27.81
29.21
31.50

10 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.52
1.52
1.52
1.52
2.03

0.455
0.485
0.515
0.615
0.670
0.785
0.895

11.56
12.32
13.08
15.62
17.02
19.94
22.73

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

130
168
229
281
377
479
644

193
250
341
418
561
713
958

SPEC 4450

March, 2012

Arctic-Flex

®

XLPE/Arctic-PVC, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER1, CSA Type RW90 XLPE, CSA Type TC
Applications (cont’d.):

•	Approved for cable in tray; industrial hazardous
locations; Class I Zone 2; and Class I, Division 2
per CEC rules 18-156 and 18-252 when used with
certified HL cable glands

Features:

Product Construction:
Conductor:

•	Rated 90˚C wet or dry
•	Ripcord applied to all cables with jacket thickness
of 60 mils or less
•	Meets CSA cold impact test at -40˚C
•	Meets ICEA and CSA cold bend test at -60˚C
•	Meets the crush and impact requirements of Type
MC cable

Print:

•	GENERAL CABLE ® (PLANT OF MFG) (UL) TYPE
TC-ER ARCTIC-FLEX® XX/C XXAWG WITH GRND
FR-XLP/PVC XHHW-2 CDRS 90C WET OR DRY
SUN RES DIR BUR 600 V (CSA) TYPE RW90
XLPE -40C TC FT4 600 V PLUS DAY/MONTH/
YEAR OF MFG SEQUENTIAL FOOTAGE MARK

•	8 AWG thru 500 kcmil bare, annealed copper per
ASTM B3
•	Class B stranding per ASTM B8	

Insulation:

•	Tinned copper
•	Class C stranding
•	Overall shielded multi-conductors
•	Optional Color Code as specified per CSA
standard C22.2 No. 38 for two to four conductor
cable
•	Non-UL 1000 volt CSA Type RW90 XLPE,
CSA Type TC
•	Other constructions are available upon request

Applications:

•	Industrial power and control circuits
•	Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors
•	Approved for direct burial; Class I, Div. 2 industrial
hazardous locations per NEC for UL Type TC
cables. In Canada protection may be required by
inspection authority per Canadian electrical code

Ground (Bonding) Conductor:
•	Uninsulated bare annealed copper
per ASTM B3
•	Class B stranding per ASTM B8

Jacket:

•	Lead-free, flame-retardant, sunlight-resistant
Arctic-grade Polyvinyl Chloride (PVC)

CATALOG
NUMBER

NO. OF
COND.

347150*
347160*
347170*
347180*
347190*
347200*
347210*
347220*
371280*
371290*
347230*
347240*
347250*
347260*
371300*
371310*
347270*
347280*
347290*
347300*
347310*
347320*
347330*

3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3

8
8
6
6
4
4
2
2
1
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
250
250
350
350
500

Industry Compliances:
	 •	UL 44 Type XHHW-2
	 •	UL 1277 Type TC-ER for 3 or more conductors,
UL File # E57179
	 •	UL 1581
	 •	ICEA S-95-658/NEMA WC70
	 •	CSA C22.2 No. 38 RW90 XLPE
	 •	CSA C22.2 No. 230 Type TC
Flame Test Compliances:
	 •	UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 •	IEEE 383
	 •	IEEE 1202
	 •	CSA FT4
Other Compliances:
	 •	EPA 40 CFR, Part 261 for leachable lead
content per TCLP
•	OSHA Acceptable

Options:

•	Lead-free, flame-retardant Cross-linked
Polyethylene (XLPE)
•	Color-coded per CSA Standard C22.2
No. 38 as follows:
Number of color coding of circuit conductors
No. of Cond.		
Color Code
	2
		
blk, wht
	3
		
blk, red, blu
	4
		
blk, red, blu, wht
	≥5		
all black
All conductors for all constructions are
alphanumeric printed

COND.
SIZE
(AWG/
kcmil)

Compliances:

GROUND
WIRE SIZE
(AWG)

COND.
STRAND
7/.0486
7/.0486
7/.0612
7/.0612
7/.0772
7/.0772
7/.0974
7/.0974
19/.0664
19/.0664
19/.0745
19/.0745
19/.0837
19/.0837
19/.0940
19/.0940
19/.1055
19/.1055
37/.0822
37/.0822
37/.0973
37/.0973
37/.1162

MINIMUM AVG.
INSULATION
THICKNESS
INCHES

mm

Packaging:

•	Material cut to lengths and shipped on
non-returnable wood reels

MINIMUM AVG.
JACKET THICKNESS NOMINAL CABLE O.D.
INCHES

mm

INCHES

mm

COPPER
WEIGHT
LBS/
1000 FT kg/km

NET WEIGHT
LBS/
1000 FT kg/km

8 AWG - 500 kcmil MULTI-CONDUCTORS
10
10
8
8
8
8
6
6
6
6
6
6
6
6
4
4
4
4
4
4
3
3
2

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.065
0.065

1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.65
1.65
1.65
1.65
1.65

0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110
0.110
0.110

1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79
2.79
2.79

0.640
0.705
0.720
0.790
0.875
0.950
1.000
1.095
1.120
1.235
1.215
1.340
1.310
1.450
1.420
1.570
1.540
1.765
1.750
1.930
1.970
2.180
2.250

16.26
17.91
18.29
20.07
22.23
24.13
25.40
27.81
28.45
31.37
30.86
34.04
33.27
36.83
36.07
39.88
39.12
44.83
44.45
49.02
50.04
55.37
57.15

190
242
301
384
448
578
716
919
872
1136
1081
1413
1341
1760
1717
2245
2132
2796
2494
3282
3474
4577
4938

283
360
448
571
667
862
1066
1368
1298
1691
1609
2103
1996
2619
2555
3341
3173
4161
3712
4884
5170
6811
7349

314
385
445
558
653
820
964
1214
1199
1704
1414
1825
1706
2223
2437
3123
2600
3444
3142
4048
4230
5470
5829

467
573
662
830
972
1220
1435
1807
1784
2536
2104
2716
2539
3308
3627
4648
3869
5125
4676
6024
6295
8140
8675

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as
defined by NEC.

Phone: 888-593-3355
www.generalcable.com

SPEC 4460

June, 2012

CCTC

™

FR-XLPE/CPE, Control, Shielded
600 V, UL Type TC-ER1 — E-1 Color Code
Product Construction:
Conductor:

• 14 AWG thru 10 AWG fully annealed stranded bare
copper per ASTM B3
• Class B stranding per ASTM B8

Insulation:

• Flame-Retardant Cross-linked Polyethene
(FR-XLPE) insulation
• Color-coded per ICEA Method 1, Table E-1
(includes white or green)

Applications:

Shield:

• Bare 5 mil corrugated copper tape longitudinally
applied

Jacket:

• Lead-free, flame-retardant thermoplastic
Chlorinated Polyethylene (CPE)

Print

• GENERAL CABLE ® (PLANT OF MFG) CCTC™
XX/C XXAWG FR-XLPE/CPE (UL) TYPE TC-ER
XHHW-2 CDRS 90°C WET OR DRY 600 V DIR
BUR SUN RES DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

Options:

• 2 kV version
• Tinned copper conductor
• Class C stranding
• E-2 Color Code
• Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II
• Thermoplastic Low-Smoke, Zero-Halogen
(LSZH) jacket
• Other constructions available upon request

CATALOG
NUMBER

NO. OF
COND.

COND.
SIZE
(AWG)

• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors
•A
 pproved for direct burial
• Class I, Division 2 industrial hazardous locations
per NEC

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties
• Sunlight- and weather-resistant
• Excellent moisture resistance
• Excellent resistance to compression cuts and heat
deformation
• Low coefficient of friction for easy pulling
• Excellent flame resistance—burns to ash;
does not exhibit thermoplastic drip
• Excellent low temperature cold bend
characteristics
• Meets cold bend test at -40˚C
• Meets the crush and impact requirements of
Type MC cable for 3 or more conductors

MINIMUM AVG.
INSULATION
THICKNESS
COND.
STRAND

INCHES

mm

MINIMUM AVG.
JACKET THICKNESS
INCHES

mm

Compliances:

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC-ER for 3 or more conductors,
UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
	 • ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

NOMINAL CABLE O.D.
INCHES

mm

COPPER
WEIGHT
LBS/
1000 FT
kg/km

NET WEIGHT
LBS/
1000 FT
kg/km

14 AWG MULTI-CONDUCTORS
397310*
397320*
397330*
397340*
397350*
397360*
397370*

2
3
4
5
7
9
12

14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

0.030
0.030
0.030
0.030
0.030
0.030
0.030

397380*
397390*
397400*
397410*
397420*
397430*
397440*

2
3
4
5
7
9
12

12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

0.030
0.030
0.030
0.030
0.030
0.030
0.030

397450*
397460*
397470*
397480*
397490*
397500*
397510*

2
3
4
5
7
9
12

10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.060
0.060
0.060
0.060

1.14
1.14
1.14
1.52
1.52
1.52
1.52

0.440
0.460
0.495
0.565
0.605
0.685
0.760

11.18
11.68
12.57
14.35
15.37
17.40
19.30

50
65
80
95
123
153
196

74
97
119
141
183
228
292

96
119
143
182
227
279
349

143
177
213
271
338
415
519

12.19
12.70
14.48
15.62
16.76
19.18
21.21

67
90
112
135
177
225
291

100
134
167
201
263
335
433

119
151
199
234
297
370
468

177
225
296
348
442
551
696

14.10
14.73
16.00
17.27
18.54
22.48
24.77

94
129
164
201
269
342
444

140
192
244
299
400
509
661

167
215
264
317
408
547
691

248
320
393
472
607
814
1028

12 AWG MULTI-CONDUCTORS
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.060
0.060
0.060
0.060
0.060

1.14
1.14
1.52
1.52
1.52
1.52
1.52

0.480
0.500
0.570
0.615
0.660
0.755
0.835

10 AWG MULTI-CONDUCTORS
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.060
0.060
0.060
0.060
0.060
0.080
0.080

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

Phone: 888-593-3355
www.generalcable.com

1.52
1.52
1.52
1.52
1.52
2.03
2.03

0.555
0.580
0.630
0.680
0.730
0.885
0.975

SPEC 4480

June, 2012

CCTC

™

FR-XLPE/CPE, Low-Voltage Power, Shielded
600 V, UL Type TC-ER1 — Method 4 Color Code
Features:

Product Construction:
Conductor:

Print:

•	8 AWG thru 2 AWG bare, annealed copper per
ASTM B3
•	Class B stranding per ASTM B8

Insulation:

•	Flame-Retardant Cross-linked Polyethylene
(FR-XLPE) insulation
•	Color-coded per ICEA Method 4; individual
conductors colored black with conductor number
surface printed in contrasting ink

Shield:

• Bare 5 mil corrugated copper tape longitudinally
applied

Ground:

•	Uninsulated bare annealed copper per
ASTM B3
•	Class B stranding per ASTM B8

NO. OF
COND.

•	2 kV version
•	Tinned copper conductor
•	Class C stranding
•	E-1 or E-2 Color Code
•	Insulated ground conductors
•	Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II
•	Flame-retardant, thermoplastic
Low-Smoke, Zero-Halogen (LSZH) jacket
•	Other constructions available upon request
•	In free air, raceways or direct burial
•	In wet or dry locations
•	Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors
•	Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC

• Lead-free, flame-retardant thermoplastic
Chlorinated Polyethylene (CPE)

CATALOG
NUMBER

Options:

Applications:

Jacket:

COND.
SIZE
(AWG)

•	GENERAL CABLE ® (PLANT OF MFG) CCTC™
XX/C XXAWG WITH GRND FR-XLPE/CPE (UL)
TYPE TC-ER XHHW-2 CDRS 90˚C WET OR DRY
600 V DIR BUR SUN RES DAY/MONTH/YEAR OF
MFG SEQUENTIAL FOOTAGE MARK

COND.
STRAND

GROUND
WIRE SIZE
(AWG)

MINIMUM AVG.
INSULATION
THICKNESS
INCHES

mm

•	Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties
•	Excellent moisture resistance
•	Excellent resistance to crush, compression cuts
and heat deformation
•	Excellent low temperature cold bend
characteristics
•	Excellent flame resistance—burns to ash; does
not exhibit thermoplastic drip
•	Low coefficient of friction for easy pulling
•	Sunlight- and weather-resistant
•	Meets cold bend test at -40˚C

Compliances:

Industry Compliances:
	 •	UL 44 Type XHHW-2
	 •	UL 1277 Type TC-ER, UL File # E57179
	 •	UL 1581
	 •	ICEA S-95-658/NEMA WC70
Flame Test Compliances:
	 •	UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 •	IEEE 383
	 •	IEEE 1202
	 •	CSA FT4
	 •	ICEA T-29-520
Other Compliances:
	 •	EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 •	OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

MINIMUM AVG.
JACKET THICKNESS NOMINAL CABLE O.D.
INCHES

mm

COPPER
WEIGHT

NET WEIGHT

INCHES

mm

LBS/
1000 FT

kg/km

LBS/
1000 FT

kg/km

0.715
0.775
0.790
0.905
0.935
1.020
1.060
1.160

18.16
19.69
20.07
22.99
23.75
25.91
26.92
29.46

229
283
336
421
499
636
755
964

341
421
500
626
743
946
1123
1434

356
435
483
634
711
888
1007
1267

530
647
719
943
1058
1321
1498
1885

8 AWG - 2 AWG MULTI-CONDUCTORS
397520*
397530*
397540*
397550*
397560*
397570*
397580*
397590*

3
4
3
4
3
4
3
4

8
8
6
6
4
4
2
2

7/.0486
7/.0486
7/.0612
7/.0612
7/.0772
7/.0772
7/.0974
7/.0974

10
10
8
8
8
8
6
6

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045

1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14

0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080

1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

Phone: 888-593-3355
www.generalcable.com

SPEC 4500

March, 2012

CVTC

®

XLPE/PVC, Control, Unshielded
600 V, UL Type TC-ER1—E-2 Color Code
Product Construction:
Conductor:

•	14 AWG thru 10 AWG fully annealed stranded bare
copper per ASTM B3
•	Class B stranding per ASTM B8

Insulation:

•	Flame-retardant Cross-linked Polyethylene (XLPE)
•	Color-coded per ICEA Method 1, Table E-2
(does not include white or green)

Jacket:

•	Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Print

•	GENERAL CABLE (PLANT OF MFG) CVTC
XX/C XXAWG FR-XLP/PVC (UL) TYPE TC-ER
XHHW-2 CDRS DIR BUR SUN RES 90˚C WET
OR DRY 600 V DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK
®

®

Options:

•	Tinned copper conductor
•	Class C stranding
•	E-1 Color Code
•	Overall shielded multi-conductors
•	Ethylene Propylene Rubber (EPR) insulation
•	Low-lead Hypalon Chlorosulfonated Polyethylene
(CSPE)/Elastomer blend—see CHTC® Spec 4050
•	Insulated or uninsulated ground conductor
•	Other constructions available upon request

Applications:

•	In free air, raceways and direct burial
•	In wet or dry locations
•A
 pproved for direct burial
• Class I, Division 2 industrial hazardous locations
per NEC
•	Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors

Features:

•	Rated at 90˚C wet or dry
•	Ripcord applied to all cables with jacket thickness
of 60 mils or less
•	Excellent electrical properties
•	Abrasion- and chemical-resistant
•	Sunlight- and weather-resistant
•	Meets cold bend test at -25˚C
•	Meets the crush and impact requirements of Type
MC cable

Compliances:

Industry Compliances:
	 •	UL 44 Type XHHW-2
	 •	UL 1277 Type TC-ER for 3 or more conductors,
UL File # E57179
	 •	UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 •	IEEE 383
	 •	IEEE 1202
	 •	ICEA T-29-520 (210,000 BTU/hr)
	 •	CSA FT4
Other Compliances:
	 •	EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 •	OSHA Acceptable

Packaging:
•	Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

14 AWG MULTI-CONDUCTORS
770460 2 Flat
2
771080*
3
770530
4
770610
5
770420
7
770560
9
770540
12
770470
19
770550
770450* 25
295320* 30
770430* 37

14
14
14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

770480
346920*
365720
770570
770490
770410
770950
770580
770520
770700*
347110*
347120*
347130*

2 Flat
2
3+ Grnd
3
4
5
7
9
12
19
25
30
37

12
12
12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

770590 2 Flat
2
346930*
770670 3+ Grnd
3
770600
4
770370
5
770380
7
770900
9
770390*
12
770400

10
10
10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

.235 x .370 5.97 x 9.40

0.365
0.390
0.425
0.465
0.590
0.620
0.680
0.800
0.985
1.050
1.130

9.27
9.91
10.80
11.81
14.99
15.75
17.27
20.32
25.02
26.67
28.70

25
25
40
53
66
93
119
159
252
323
387
490

37
37
59
79
99
138
177
237
375
481
571
729

62
73
93
116
140
176
245
302
460
641
740
888

92
109
138
173
208
262
365
449
685
954
1101
1322

40
41
86
65
86
108
150
193
258
403
515
618
741

60
86 128
61
96 143
128 143 213
96 125 186
128 157 234
160 191 284
224 260 387
288 340 506
385 429 638
600 681 1013
767 885 1317
920 1005 1496
1103 1185 1764

66
67
135
101
135
167
234
295
402

98
100
200
150
200
249
349
440
598

12 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

.245 x .400 6.22 x 10.16

0.410
0.435
0.435
0.475
0.515
0.595
0.695
0.780
0.930
1.095
1.150
1.240

10.41
11.05
11.05
12.07
13.08
15.11
17.65
19.81
23.62
27.81
29.21
31.50

10 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03

.290 x .480 7.37 x 12.19

0.455
0.485
0.485
0.515
0.615
0.670
0.785
0.895

11.56
12.32
12.32
13.08
15.62
17.02
19.94
22.73

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
1 Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

114
130
201
173
236
287
371
479
644

170
193
299
257
351
427
552
713
958

SPEC 4550

March, 2012

CVTC

®

XLPE/PVC, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER1—Method 4 Color Code
Features:

•	Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
•	Abrasion- and chemical-resistant
•	Excellent electrical properties
•	Sunlight- and weather-resistant
•	Meets cold bend test at -25˚C
•	Meets the crush and impact requirements of
Type MC cable

Product Construction:
Conductor:

Print (cont’d.):

•	14 AWG thru 750 kcmil bare, annealed copper per
ASTM B3
•	Class B stranding per ASTM B8

•	Tinned copper conductor
•	Class C stranding
•	E-1 or E-2 Color Code
•	Insulated ground conductors
•	Overall shielded multi-conductors
•	Flame-retardant Ethylene Propylene Rubber (EPR)
insulation
•	Low-lead Hypalon Chlorosulfonated Polyethylene
(CSPE)/Elastomer blend—see CHTC® Spec 4100
•	ICEA 1000 V rated cable
• Other constructions available upon request

•	Flame-retardant Cross-linked Polyethylene (XLPE)
•	Color-coded per ICEA Method 4; individual
conductors colored black with conductor
number surface printed in contrasting ink

Ground:

•	Uninsulated bare annealed copper
per ASTM B3
•	Class B stranding per ASTM B8

Jacket:

Applications:

•	Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)
•	GENERAL CABLE ® (PLANT OF MFG) CVTC®
XX/C XXAWG WITH GRND FR-XLP/PVC (UL)

NO. OF
COND.

Packaging:

•	In free air, raceways or direct burial
•	In wet or dry locations
•	Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC
•	Permitted for Exposed Run (ER) use in
accordance with NEC

Print:

CATALOG
NUMBER

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC-ER, UL File # E57179
	 • UL 1581
	 • ICEA S-95-658/NEMA WC70
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 •	ICEA T-29-520 (210,000 BTU/hr)
	 • CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Options:

Insulation:

COND.
SIZE
(AWG/
kcmil)

Compliances:

TYPE TC-ER XHHW-2 CDRS 90˚C WET OR DRY
DIR BUR SUN RES 600 V DAY/MONTH/YEAR
SEQUENTIAL FOOTAGE MARK

COND.
STRAND

GROUND
WIRE SIZE
(AWG)

MINIMUM AVG.
INSULATION
THICKNESS
INCHES

mm

•	Material cut to length and shipped on
non-returnable wood reels

MINIMUM AVG.
JACKET THICKNESS NOMINAL CABLE O.D.
INCHES

mm

INCHES

mm

COPPER
WEIGHT
LBS/
1000 FT kg/km

NET WEIGHT
LBS/
1000 FT kg/km

14 AWG - 750 kcmil MULTI-CONDUCTORS
383860*
383870*
383880*
783160
783190
339470
339480
783330
339500*
325610
339520*
352150*
371250*
339530
339540*
339550
339560*
371260*
371270*
783230
339570*
328540*
339590*
222570
339600*
222710
06790.086500*
06790.077000*
06790.047000*

3
3
3
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4

14
12
10
8
8
6
6
4
4
2
2
1
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
250
250
350
350
500
500
750
750

7/.0242
7/.0305
7/.0385
7/.0486
7/.0486
7/.0612
7/.0612
7/.0772
7/.0772
7/.0974
7/.0974
19/.0664
19/.0664
19/.0745
19/.0745
19/.0837
19/.0837
19/.0940
19/.0940
19/.1055
19/.1055
37/.0822
37/.0822
37/.0973
37/.0973
37/.1162
37/.1162
61/.1109
61/.1109

14
12
10
10
10
8
8
8
8
6
6
6
6
6
6
6
6
4
4
4
4
4
4
3
3
2
2
1
1

0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.065
0.065
0.065
0.080
0.080

0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.65
1.65
1.65
1.65
1.65
1.65
2.03
2.03

0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.140
0.140

1.14
1.14
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79
2.79
2.79
2.79
3.56
3.56

0.390
0.435
0.485
0.640
0.705
0.720
0.790
0.875
0.950
1.000
1.095
1.120
1.235
1.215
1.340
1.310
1.450
1.420
1.570
1.540
1.765
1.750
1.930
1.970
2.180
2.250
2.475
2.810
3.115

9.91
11.05
12.32
16.26
17.91
18.29
20.07
22.23
24.13
25.40
27.81
28.45
31.37
30.86
34.04
33.27
36.83
36.07
39.88
39.12
44.83
44.45
49.02
50.04
55.37
57.15
62.87
71.37
79.12

53
86
135
190
242
301
384
448
578
716
919
872
1136
1081
1413
1341
1760
1717
2245
2132
2796
2494
3282
3474
4577
4938
6509
7278
9712

79
128
200
283
360
448
571
667
862
1066
1368
1298
1691
1609
2103
1996
2619
2555
3341
3173
4161
3712
4884
5170
6811
7349
9687
10831
14453

116
157
236
314
385
445
558
653
820
964
1214
1199
1704
1414
1825
1706
2223
2437
3123
2600
3444
3142
4048
4230
5470
5829
7579
9101
11746

173
234
351
467
573
662
830
972
1220
1435
1807
1784
2536
2104
2716
2539
3308
3627
4648
3869
5125
4676
6024
6295
8140
8675
11279
13544
17480

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
1 Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

Phone: 888-593-3355
www.generalcable.com

SPEC 4575

March, 2012

CVTC VFD
®

XLPE/PVC, Low-Voltage Power, Shielded
2000 V, UL Type TC-ER1—Method 4 Color Code
Product Construction:
Conductor:

•	14 AWG thru 500 kcmil fully annealed tinned
stranded copper
•	Class B stranding per ASTM B8

Insulation:

•	Flame-retardant Cross-linked Polyethylene
(XLPE)—90°C, VW-1
•	Color-coded per ICEA Method 4; individual
conductors colored black with conductor
number surface printed in contrasting ink

Applications:

Ground:

•	3 symmetrically placed annealed tinned copper
conductors in direct contact with shield
•	Class B stranding per ASTM B8

Dual Shield:

•	Overall tinned copper braided shield in
conjunction with an aluminum/polymer
tape shield

Jacket:

•	Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

NO. OF
COND.

384730*
384740*
384750*
384760*
384770*
384780*
384790*
384800*
384810*
384820*
384830*
384840*
384850*
384860*

3
3
3
3
3
3
3
3
3
3
3
3
3
3

14
12
10
8
6
4
2
1/0
2/0
3/0
4/0
250
350
500

Compliances:

Industry Compliances:
	 • UL 1277 Type TC-ER, UL File # E57179
	 • UL Type RHH or RHW-2 conductors per UL 44
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 •	ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

•	Rated at 90˚C wet or dry
• Dual shield provides maximum shield coverage
required for Variable Frequency Drive (VFD)
applications
•	Meets cold bend test at -25°C
•	Meets crush and impact requirements to Type MC
cable

•	GENERAL CABLE ® (PLANT OF MFG) CVTC® VFD
XX/C XXAWG WITH GRND FR-XLP/PVC (UL)
TYPE TC-ER RHH or RHW-2 CDRS 90˚C WET OR
DRY 2000 V DIR BUR SUN RES DAY/MONTH/
YEAR SEQUENTIAL FOOTAGE MARK

CATALOG
NUMBER

•	Abrasion- and chemical-resistant
•	Excellent electrical properties
•	Sunlight- and weather-resistant

Features:

Print:

COND.
SIZE
(AWG/
kcmil)

Features (cont’d.):

•	For use with AC motors controlled by pulse-width
modulated inverter in VFD applications rated
up to 2000 volts. These motor drive systems
require cables that are designed to prevent radio
frequency interference (RFI) which can lead to
malfunction
•	In raceways, cable trays or direct burial
•	In wet or dry locations
•	Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC
•	Permitted for Exposed Run (ER) use in
accordance with NEC

COND.
STRAND
7/.0242
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772
7/.0974
19/.0745
19/.0837
19/.0940
19/.1055
37/.0822
37/.0973
37/.1162

GROUND
WIRE SIZE
(AWG)

MINIMUM AVG.
INSULATION
THICKNESS
INCHES

mm

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

MINIMUM AVG.
JACKET THICKNESS NOMINAL CABLE O.D.
INCHES

mm

INCHES

COPPER
WEIGHT

mm

LBS/
1000 FT

14.35
15.37
16.89
19.94
23.11
25.65
28.83
35.31
37.85
40.51
45.09
49.28
54.86
61.98

79
114
172
234
354
507
783
1251
1511
1897
2355
2719
3883
5507

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

118
170
256
348
527
755
1165
1861
2248
2823
3504
4046
5778
8194

190
236
313
420
605
800
1126
1832
2134
2553
3254
3726
5040
6809

283
351
466
625
900
1191
1676
2726
3175
3799
4842
5544
7500
10132

14 AWG - 500 kcmil MULTI-CONDUCTORS
3 x 18
3 x 16
3 x 14
3 x 14
3 x 12
3 x 12
3 x 10
3x6
3x6
3x5
3x4
3x4
3x2
3x1

0.060
0.060
0.060
0.070
0.070
0.070
0.070
0.090
0.090
0.090
0.090
0.105
0.105
0.105

1.52
1.52
1.52
1.78
1.78
1.78
1.78
2.29
2.29
2.29
2.29
2.67
2.67
2.67

0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
1 Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

Phone: 888-593-3355
www.generalcable.com

1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79

0.565
0.605
0.665
0.785
0.910
1.010
1.315
1.390
1.490
1.595
1.775
1.940
2.160
2.440

SPEC 4580

March, 2012

CVTC VFD
®

XLPE/PVC, Low-Voltage Power, Copper Tape Shielded
2000 V, UL Type TC-ER1—Method 4 Color Code
Features:

Product Construction:
Conductor:

Jacket:

•	Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

•	14 AWG thru 500 kcmil fully annealed bare
stranded copper
•	Class B stranding per ASTM B8

Compliances:

Industry Compliances:
	 •	UL 1277 Type TC-ER, 2000 V, UL File # E57179
	 •	UL Type RHH or RHW-2 conductors per UL 44
Flame Test Compliances:
	 • UL 1581/UL 2556 VW-1
	 • UL 1685 Vertical Flame Test
	 •	IEEE 383
	 •	IEEE 1202
	 •	ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 •	EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 •	OSHA Acceptable

Print:

•	GENERAL CABLE ® (PLANT OF MFG) CVTC® VFD
XX/C XXAWG WITH GRNDS FR-XLP/PVC (UL)
TYPE TC-ER RHH or RHW-2 CDRS 90˚C WET OR
DRY 2000 V DIR BUR SUN RES DAY/MONTH/
YEAR SEQUENTIAL FOOTAGE MARK

Insulation:

•	Flame-retardant Cross-linked Polyethylene
(XLPE)—90°C, VW-1
•	Color-coded per ICEA Method 4; individual
conductors colored black with conductor
number surface printed in contrasting ink

Applications:

•	For use with AC motors controlled by pulse-width
modulated inverter in VFD applications rated
up to 2000 volts. These motor drive systems
require cables that are designed to prevent radio
frequency interference (RFI) which can lead to
malfunction
•	In raceways, cable trays or direct burial
•	In wet or dry locations
•	Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC
•	Permitted for Exposed Run (ER) use in
accordance with NEC

Ground:

•	3 symmetrically placed annealed bare copper
conductors in direct contact with shield
•	Class B stranding per ASTM B8

Metallic Shield:

•	Overall 5 mil annealed bare copper tape shield
with 50% overlap

CATALOG
NUMBER

•	Rated at 90˚C wet or dry
•	Overlapped bare copper tape shield provides
necessary shield coverage required for Variable
Frequency Drive (VFD) applications
•	Meets cold bend test at -25°C
•	Meets crush and impact requirements for
Type MC cable
•	Abrasion- and chemical-resistant
•	Excellent electrical properties
•	Sunlight- and weather-resistant

NO. OF
COND.

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

3
3
3
3
3
3
3
3
3
3
3
3
3
3

14
12
10
8
6
4
2
1/0
2/0
3/0
4/0
250
350
500

7/.0242
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772
7/.0974
19/.0745
19/.0837
19/.0940
19/.1055
37/.0822
37/.0973
37/.1162

GROUND
WIRE SIZE
(AWG)

MINIMUM AVG.
INSULATION
THICKNESS
INCHES

mm

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

MINIMUM AVG.
JACKET THICKNESS NOMINAL CABLE O.D.
INCHES

mm

INCHES

COPPER
WEIGHT

mm

LBS/
1000 FT

14.73
15.37
17.02
19.56
22.73
25.27
28.58
35.18
37.59
40.39
45.21
49.28
54.86
62.36

91
127
183
246
368
522
801
1348
1616
2010
2517
2895
4089
5693

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

135
189
272
366
548
777
1192
2006
2405
2991
3745
4308
6084
8471

212
260
329
441
618
830
1152
1853
2169
2619
3241
3763
5109
6933

315
387
490
656
920
1235
1714
2757
3227
3897
4823
5599
7602
10316

14 AWG - 500 kcmil MULTI-CONDUCTORS
395070V
395080V
395090V
395100V
395110V
395120V
395130V
395140V
395150V
395160V*
395170V
395180V*
395190V
395200V

3 x 18
3 x 16
3 x 14
3 x 14
3 x 12
3 x 12
3 x 10
3x6
3x6
3x5
3x4
3x4
3x2
3x1

0.060
0.060
0.060
0.070
0.070
0.070
0.070
0.090
0.090
0.090
0.090
0.105
0.105
0.105

1.52
1.52
1.52
1.78
1.78
1.78
1.78
2.29
2.29
2.29
2.29
2.67
2.67
2.67

0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110

1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79

0.580
0.615
0.670
0.770
0.895
0.995
1.125
1.385
1.480
1.590
1.780
1.940
2.160
2.455

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
1 Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

Phone: 888-593-3355
www.generalcable.com

SPEC 4600

March, 2012

VNTC

®

PVC/Nylon/PVC, Control, Unshielded
600 V, UL Type TC-ER1 (18 AWG/16 AWG)—E-2 Color Code
Product Construction:
Conductor:

•	18 AWG and 16 AWG fully annealed stranded bare
copper to ASTM B3
•	Class B stranding per ASTM B8

Insulation:

•	Flame-retardant Polyvinyl Chloride (PVC) with
clear Polyamide (nylon)
•	Color-coded per ICEA Method 1, Table E-2 plus
alpha-numeric printed numbers (does not include
white or green)

Jacket:

•	Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Print

•	GENERAL CABLE ® (PLANT OF MFG) VNTC®
XX/C XXAWG (UL) TYPE TC-ER TFN SUN RES
DIR BUR 600 V ROHS DAY/MONTH/YEAR OF
MFG SEQUENTIAL FOOTAGE MARK

Options:

•	Tinned copper conductor
•	Class C stranding
•	E-1 Color Code
•	Overall shielded multi-conductors
•	Other constructions available upon request

Applications:

•	In free air, raceways or direct burial
•	In wet or dry locations
•A
 pproved for direct burial
• Class I, Division 2 industrial hazardous locations
per NEC
•	Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors

Features:

•	Rated at 90˚C dry, 75˚C wet
•	Ripcord applied to all cables with jacket thickness
of 60 mils or less
•	Provides outstanding sunlight, cold bend and cold
impact resistance
•	Offers the smallest cable O.D. available for
suitable applications
•	Provides long service life
•	Provides good oil and chemical resistance
•	Meets cold bend test at -25˚C
•	Meets the crush and impact requirements of Type
MC cable

Compliances:

Industry Compliances:
	 •	UL 66 NEC Type TFN conductors
	 •	UL 1277 Type TC-ER for 3 or more conductors,
UL File # E57179
	 •	UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1685 Vertical Flame Test
	 •	IEEE 383
	 •	IEEE 1202
	 •	CSA FT4
Other Compliances:
	 •	EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 •	OSHA Acceptable
	 •	RoHS Compliant

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
CABLE O.D. LBS/
OF
SIZE COND. THICKNESS
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

18 AWG MULTI-CONDUCTORS
236090 2 Flat
2
318050*
3
245920
4
236100
5
244680
7
244660
9
264570*
233270* 10
12
236120
15
244720*
19
236130
25
236140*
30
347140*
37
236150

18
18
18
18
18
18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

236160 2 Flat
2
245580
3
236170
4
236180
5
236190
7
236210
9
243640
236230* 10
12
236240
244650* 15
19
236260
25
236280
244670* 30
236290* 37

16
16
16
16
16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060

1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52

.190 x .285 4.80 x 7.20

0.270
0.285
0.310
0.335
0.360
0.420
0.425
0.445
0.485
0.570
0.655
0.695
0.745

6.86
7.24
7.87
8.51
9.14
10.67
10.80
11.30
12.32
14.48
16.64
17.65
18.92

10
11
15
20
26
36
46
51
61
77
97
128
154
189

15
19
23
30
38
53
69
76
91
114
144
190
229
281

36
38
46
56
65
82
105
114
131
162
209
266
310
371

54
57
68
83
97
122
156
170
195
241
311
396
461
552

16
20
24
32
40
56
72
80
97
121
153
201
242
306

24
29
36
48
60
84
108
119
144
180
228
299
360
455

42
50
60
74
97
111
141
154
178
239
284
364
426
552

71
74
89
110
144
165
210
229
265
356
423
542
634
821

16 AWG MULTI-CONDUCTORS
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03

.200 x .310 5.08 x 7.87

0.300
0.315
0.340
0.370
0.400
0.460
0.495
0.505
0.605
0.635
0.705
0.760
0.880

7.62
8.00
8.64
9.40
10.16
11.68
12.57
12.83
15.37
16.13
17.91
19.30
22.35

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
1 Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

SPEC 4650

March, 2012

VNTC

®

PVC/Nylon/PVC, Control, Unshielded
600 V, UL Type TC-ER1 (14 AWG—10 AWG)—E-2 Color Code
Product Construction:
Conductor:

• 14 AWG thru 10 AWG fully annealed stranded bare
copper per ASTM B3
• Class B stranding per ASTM B8

Insulation:

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

14 AWG MULTI-CONDUCTORS
235040 2 Flat
2
245590*
3
235050
4
235060
5
235070
7
235080
9
235090
12
235110
19
235130
25
235150
235160* 30
37
235170

14
14
14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

234580
260150*
234590
255090
277460²
234600
226420
234620
226500
234640
243600
243610*
321720*
234680*

2 Flat
2
3
3+Grnd
3
4
5
7
9
12
19
25
30
37

12
12
12
12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0035

236300 2 Flat
2
243630*
3
236310
255080 3+Grnd
4
236320
5
236330
7
236340
9
243620*
12
236350

10
10
10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03

.210 x .320 5.33 x 8.13

0.320
0.345
0.365
0.410
0.445
0.505
0.595
0.695
0.785
0.895
0.970

8.13
8.76
9.27
10.41
11.30
12.83
15.11
17.65
19.94
22.73
24.64

0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

.225 x .360 5.72 x 9.14

0.355
0.385
0.385
0.385
0.420
0.445
0.490
0.605
0.675
0.785
0.940
1.030
1.105

9.02
9.78
9.78
9.78
10.67
11.30
12.45
15.37
17.15
19.94
23.88
26.16
28.07

37
39
58
77
97
134
173
231
365
481
576
711

54
64
80
100
118
153
213
267
396
507
637
766

80
95
119
149
176
228
317
397
589
755
948
1140

40
41
62
83
62
83
108
144
185
247
391
515
618
762

60
74
110
61
85
127
92 131 195
124 131 195
92 131 195
124 138 205
160 165 246
214 217 323
275 297 442
368 377 561
582 568 845
767 775 1153
920 919 1368
1134 1100 1637

64
65
131
131
135
169
236
295
404

95
97
195
195
200
252
351
440
602

10 AWG MULTI-CONDUCTORS
0.026
0.026
0.026
0.026
0.026
0.026
0.026
0.026
0.026

0.66
0.66
0.66
0.66
0.66
0.66
0.66
0.66
0.66

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52

.260 x .425 6.60 x 10.80

0.420
0.450
0.450
0.505
0.570
0.620
0.725
0.815

10.67
11.43
11.43
12.83
14.48
15.75
18.42
20.70

Jacket:

•	Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Print
25
26
39
52
65
90
116
155
245
323
387
478

12 AWG MULTI-CONDUCTORS
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020

• Flame-retardant Polyvinyl Chloride (PVC) with
clear Polyamide (nylon)
• Color-coded per ICEA Method 1, Table E-2 plus
alpha-numeric printed numbers (does not include
white or green)

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.
² Color Code: black, white, green

108
115
191
191
209
268
350
440
584

161
171
284
284
311
399
521
655
869

• GENERAL CABLE ® (PLANT OF MFG) VNTC®
XX/C XXAWG (UL) TYPE TC-ER THHN/THWN
SUN RES DIR BUR 600 V ROHS DAY/MONTH/
YEAR OF MFG SEQUENTIAL FOOTAGE MARK

Options:

• Tinned copper conductor
• Class C stranding
• E-1 Color Code
• Overall shielded multi-conductors
• Other constructions available upon request

Applications:

• In free air, raceways and direct burial
• In wet or dry locations
•A
 pproved for direct burial
• Class I, Division 2 industrial hazardous locations
per NEC
• Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors

Features:

• Rated at 90˚C dry, 75˚C wet
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Provides outstanding sunlight, cold bend and cold
impact resistance
• Offers the smallest cable O.D. available for
suitable applications
• Provides long service life
• Provides good oil and chemical resistance
• Meets cold bend test at -25˚C
• Meets the crush and impact requirements of
Type MC cable

Compliances:

Industry Compliances:
	 • UL 83 NEC Type THHN/THWN conductors
	 • UL 1277 Type TC-ER for 3 or more conductors,
UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable
	 •	RoHS Compliant

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 4700

March, 2012

VNTC

®

PVC/Nylon/PVC, Control, Shielded
600 V, UL Type TC-ER1, Overall Shielded—E-2 Color Code
Product Construction:
Conductor:

• 18 AWG thru 10 AWG fully annealed stranded bare
copper per ASTM B3
• Class B stranding per ASTM B8

Insulation:

• Flame-retardant Polyvinyl Chloride (PVC) with
clear Polyamide (nylon)
• Color-coded per ICEA Method 1, Table E-2 plus
alpha-numeric printed numbers (does not include
white or green)

Shield:

Overall shielded multi-conductor
• Overall shield is Flexfoil® aluminum/polymer,
in contact with stranded tinned copper drain wire

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

OVERALL SHIELDED MULTI-CONDUCTORS
18 AWG CONDUCTORS

Jacket:

•	Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Print

• GENERAL CABLE ® (PLANT OF MFG) SHIELDED
VNTC® XX/C XX AWG (UL) TYPE TC-ER TFN OR
THHN/THWN SUN RES DIR BUR 600 V ROHS
DAY/MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

261130
261140
261150
260000*
259980*

2
3
4
5
7

Options:

• Tinned copper conductor
• Class C stranding
• E-1 Color Code
• Unshielded multi-conductors
• Other constructions available upon request

Applications:

• In free air, raceways and direct burial
• In wet or dry locations
•A
 pproved for direct burial
• Class I, Division 2 industrial hazardous locations
per NEC
• Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors

Features:

• Rated at 90˚C dry, 75˚C wet
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Provides outstanding sunlight, cold bend and cold
impact resistance
• Offers the smallest cable O.D. available for
suitable applications
• Provides long service life
• Provides good oil and chemical resistance
• Meets cold bend test at -25˚C
• Meets the crush and impact requirements of
Type MC cable

Compliances:

Industry Compliances:
	 • UL 1277 Type TC-ER for 3 or more conductors,
UL File # E57179
	 • UL 1581
	 • UL 66 NEC Type TFN conductors
(16 & 18 AWG)
	 • UL 83 NEC Type THHN/THWN conductors
(14 through 10 AWG)
	 • ICEA S-73-532/NEMA WC57
Flame Test Compliances:
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable
	 •	RoHS Compliant

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.020
0.020
0.020
0.020
0.020

0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.045
0.045

1.14
1.14
1.14
1.14
1.14

0.280
0.290
0.310
0.340
0.370

7.11
7.37
7.87
8.64
9.40

12
18
23
28
39

19
26
34
41
58

40
49
58
70
89

60
73
86
104
132

29
41
53
65
89
113
149

52
63
77
91
119
150
185

77
94
115
135
177
223
275

46
65
85
104
142

67
84
104
123
161

100
125
155
183
240

64
95
126

83
111
139

124
165
207

101
150
198

119
162
205

177
241
305

OVERALL SHIELDED MULTI-CONDUCTORS
16 AWG CONDUCTORS
247620
261160
243710
266580*
243740*
243560*
229600*

2
3
4
5
7
9
12

16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.020
0.020
0.020
0.020
0.020
0.020
0.020

0.51
0.51
0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.045
0.045
0.045
0.045

1.14
1.14
1.14
1.14
1.14
1.14
1.14

0.300 7.62
0.320 8.13
0.350 8.89
0.370 9.40
0.410 10.41
0.470 11.97
0.510 12.95

20
28
36
44
60
76
100

OVERALL SHIELDED MULTI-CONDUCTORS
14 AWG CONDUCTORS
243660
243720
243650
243570*
243580

2
3
4
5
7

14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

0.020
0.020
0.020
0.020
0.020

0.51
0.51
0.51
0.51
0.51

0.045
0.045
0.045
0.045
0.045

1.14
1.14
1.14
1.14
1.14

0.330 8.38
0.350 8.89
0.380 9.65
0.400 10.16
0.440 11.18

31
44
57
70
96

OVERALL SHIELDED MULTI-CONDUCTORS
12 AWG CONDUCTORS
243670
243810*
243840

2
3
4

12
12
12

7/.0305 0.020 0.51 0.045 1.14 0.370 9.40
7/.0305 0.020 0.51 0.045 1.14 0.390 9.91
7/.0305 0.020 0.51 0.045 1.14 0.420 10.67

43
64
85

OVERALL SHIELDED MULTI-CONDUCTORS
10 AWG CONDUCTORS
243770*
243820*
243690*

2
3
4

10
10
10

7/.0385 0.026 0.66 0.045 1.14 0.430 10.92
7/.0385 0.026 0.66 0.045 1.14 0.460 11.68
7/.0385 0.026 0.66 0.045 1.14 0.500 12.70

68
101
133

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

SPEC 4750

March, 2012

VNTC

®

PVC/Nylon/PVC, Low-Voltage Power, Unshielded
600 V, UL Type TC-ER1 — Method 4 Color Code
Features:

Product Construction:
Conductor:

•	Rated at 90˚C dry, 75˚C wet
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
•	Provide outstanding sunlight, cold bend and cold
impact resistance
•	Offer the smallest cable O.D. available for suitable
applications
•	Provide good oil and chemical resistance
•	Provides a long service life
•	Meets cold bend test at -25˚C
•	Meets the crush and impact requirements of
Type MC cable

Print:

• GENERAL CABLE ® (PLANT OF MFG) VNTC®
XX/C XXAWG WITH GRND (UL) TYPE TC-ER
THHN/THWN CDRS DIR BUR SUN RES 600 V
ROHS DAY/MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

•	14 AWG thru 500 kcmil bare, annealed
copper per ASTM B3
•	Class B stranding per ASTM B8

Insulation:

Compliances:

Industry Compliances:
	 • NEC Type THHN/THWN conductors
	 • UL 1277 Type TC-ER, UL File # E57179
	 • UL 1581
	 • ICEA S-95-658/NEMA WC70
Flame Test Compliances:
	 • UL 1685 Vertical Flame Test
	 • IEEE 383
	 • IEEE 1202
	 • CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable
	 •	RoHS Compliant

Options:

•	Flame-retardant Polyvinyl Chloride (PVC) with
clear Polymide (nylon)
•	Color-coded per ICEA Method 4; individual
conductors colored black with conductor number
surface printed in contrasting ink

• Tinned copper conductor
• Class C stranding
• Insulated ground conductors
• 5 mil bare copper tape shield with 25% overlap
• Other constructions available upon request

Ground:

Applications:

•	Uninsulated bare annealed copper per ASTM B3
•	Class B stranding per ASTM B8

•	In free air, raceways or direct burial
•	In wet or dry locations
•	Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC
•	Permitted for Exposed Run (ER) use in
accordance with NEC

Jacket:

•	Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

CATALOG
NUMBER

NO. OF
COND.

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

GROUND
WIRE SIZE
(AWG)

MINIMUM AVG.
INSULATION
THICKNESS
INCHES

mm

MINIMUM AVG.
JACKET THICKNESS NOMINAL CABLE O.D.
INCHES

mm

INCHES

mm

COPPER
WEIGHT
LBS/
1000 FT kg/km

NET WEIGHT
LBS/
1000 FT kg/km

14 AWG - 500 kcmil MULTI-CONDUCTORS
383890*
234250
234260
386700**
236370
236380
226410
231980
236400
236410*
236420
236430*
236440
219580*
243760
219610*
221560
329240*
222490
297050*
226430
297060*
219630
222510*

3
3
3
3
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4

14
12
10
10
8
8
6
6
4
4
2
2
1/0
1/0
2/0
2/0
4/0
4/0
250
250
350
350
500
500

7/.0242
7/.0305
7/.0385
7/.0385
7/.0486
7/.0486
7/.0612
7/.0612
7/.0772
7/.0772
7/.0974
7/.0974
19/.0745
19/.0745
19/.0837
19/.0837
19/.1055
19/.1055
37/.0822
37/.0822
37/.0973
37/.0973
37/.1162
37/.1162

14
12
10
10
10
10
8
8
8
8
6
6
6
6
6
6
4
4
4
4
3
3
2
2

0.020
0.020
0.020
0.020
0.036
0.036
0.036
0.036
0.048
0.048
0.048
0.048
0.059
0.059
0.059
0.059
0.059
0.059
0.070
0.070
0.070
0.070
0.070
0.070

0.51
0.51
0.51
0.51
0.91
0.91
0.91
0.91
1.22
1.22
1.22
1.22
1.50
1.50
1.50
1.50
1.50
1.50
1.78
1.78
1.78
1.78
1.78
1.78

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110
0.110
0.110
0.110

1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79
2.79
2.79
2.79

0.345
0.385
0.450
0.450
0.600
0.655
0.690
0.760
0.875
0.970
1.000
1.100
1.225
1.360
1.320
1.455
1.545
1.770
1.740
1.945
1.990
2.190
2.270
2.505

8.76
9.78
11.43
11.43
15.24
16.64
17.53
19.30
22.28
24.64
25.40
27.94
31.12
34.54
33.53
36.96
39.24
44.96
44.20
49.40
50.55
55.63
57.66
63.63

52
86
135
135
189
241
300
383
446
578
710
919
1080
1413
1340
1760
2130
2796
2494
3281
3474
4586
4934
6509

77
128
200
200
281
359
446
570
664
860
1057
1368
1607
2103
1994
2619
3170
4161
3696
4883
5170
6825
7343
9687

100
138
209
209
308
373
434
533
650
824
964
1227
1447
1830
1754
2252
2630
3502
3177
4107
4263
5585
5890
7694

149
205
311
311
458
555
646
793
967
1226
1435
1826
2153
2723
2610
3351
3914
5212
4728
6112
6344
8312
8765
11450

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**E-2 Color Code.
¹ Approved as TYPE TC-ER for Exposed Run applications as defined by NEC.

Phone: 888-593-3355
www.generalcable.com

SPEC 4775

November, 2013

TC-Flex Tray Cable 18 AWG (1,0 mm ) — 16 AWG (1,5 mm )
™

²

²

UL Type WTTC 1000 V or Type TC-ER 600 V or Type MTW and c(UL) CIC/TC 600 V FT4 or CSA AWM
90°C 1000 V, Flexible, Oil Res I/II, Sunlight- and Torsion-Resistant, Flame-Retardant, -40˚C to +90˚C
Product Construction:
Conductors:

• 18 AWG (1,0 mm²) and 16 AWG (1,5 mm²) fully
annealed flexible stranded bare copper with
Class 5 stranding per EN 60228 (IEC 60228)

Insulation:

• Polyvinyl Chloride (PVC) insulation with a clear
Polyamide (nylon) jacket per UL 83

Conductor Identification:

• Conductors are black with printed numbers and
green/yellow grounding conductor

Cable Assembly:

• Conductors cabled with non-hygroscopic fillers
to make the cable suitably round

Jacket:

• Black, flexible, flame-retardant, sunlight- and oilresistant Polyvinyl Chloride (PVC) jacket

Print:

• GENERAL CABLE® TC-FLEX™ XX/C XXAWG
(XXMM2) (UL) TC-ER TYPE TFFN 90˚C DRY
600 V SUN RES DIR BUR OIL RES I/II OR MTW
OR WTTC 1000 V 90˚C DRY c(UL) CIC/TC PVC/N
90˚C FT4 --- CSA AWM I/II A/B 90˚C 1000 V
– ROHS CE – MADE IN USA DAY/MONTH/YEAR
OF MFG SEQUENTIAL FOOTAGE MARKER

Minimum Bending Radius:
• 4x O.D. for fixed installation
• 8x O.D. for flexing applications

CATALOG
NUMBER

NO. OF COND.
INC. GRND.

NOM. INS. THICKNESS

Torsion:

Specifications:

Design Adherence:
• UL 66 & UL 83/CSA C22.2 No. 75-08
Thermoplastic Insulated Wires
• UL 1063/MTW Machine Tool Wire
• UL 1277 Power and Control Tray Cables
• UL 2277 Wind Turbine Tray Cables
• CSA C22.2 No. 230-09 Tray Cables
• CSA C22.2 No. 239-09 Control and
Instrumentation Cables
• CSA C22.2 No. 210-11 Appliance Wiring
Material Products
Flame Tests:
• IEEE 1202/CSA FT4
Compliances:
• Type TC-ER 90°C Dry, 75°C Wet, 600 V
• Type MTW
• Type WTTC 90°C, 1000 V
• Type CIC/TC 90°C, 600 V
• Type AWM I/II A/B, 90°C, 1000 V FT4
• RoHS Compliant

• 10,000 cycles at -40°C, +/- 150° twist per meter,
cable weight compensated to 20 meters

Applications:
• In free air, raceways or direct burial
• (UL) WTTC cables for use up to 1000 V in wind
turbine generator applications in accordance with
UL Subject 6140
• (UL) TC-ER cables for use up to 600 V as power
and control cables in accordance with NEC®
Article 336
• (UL) MTW cables for machine tool and wire up to
600 V as power and control cables in accordance
with UL 1063
• (CSA) CIC/TC cables for use up to 600 V in cable
trays and other applications when installed in
accordance with the Canadian Electrical Code,
Part I
• (CSA) AWM cables for use up to 1000 V as
equipment wiring in accordance with the
Canadian Electrical Code, Part I

NOM. JACKET THICKNESS
mm

NOM. CABLE O.D.
INCHES

mm

NOM. COPPER WEIGHT
LBS/1000 FT

kg/km

NOM. CABLE WEIGHT
LBS/1000 FT

kg/km

90°C AMP. @
30°C AMBIENT¹

INCHES

mm

INCHES

3

0.021

0.53

0.048

1.22

0.313

7.9

18

26

50

74

8

4

0.021

0.53

0.048

1.22

0.338

8.6

23

35

61

90

8

18 AWG (1,0 mm²) 19 Strands

4775.03018
4775.04018
4775.05018
4775.07018
4775.09018*
4775.12018
4775.16018
4775.19018
4775.25018*
4775.30018*
4775.37018*

5

0.021

0.53

0.048

1.22

0.363

9.2

29

43

72

107

8

7

0.021

0.53

0.048

1.22

0.409

10.4

41

61

93

138

8

9

0.021

0.53

0.048

1.22

0.448

11.4

53

78

114

169

7

12

0.021

0.53

0.048

1.22

0.497

12.6

70

104

144

214

7

16

0.021

0.53

0.063

1.60

0.578

14.7

94

139

197

294

6

19

0.021

0.53

0.063

1.60

0.623

15.8

111

165

229

340

6

25

0.021

0.53

0.063

1.60

0.697

17.7

146

217

289

429

6

30

0.021

0.53

0.063

1.60

0.735

18.7

175

261

336

500

5

37

0.021

0.53

0.063

1.60

0.789

20.0

216

322

402

598

5

16 AWG (1,5 mm²) 28 Strands

4775.03016
4775.04016
4775.05016
4775.07016
4775.09016*
4775.12016
4775.16016
4775.19016
4775.25016
4775.30016*
4775.37016*

3

0.021

0.53

0.048

1.22

0.339

8.6

26

39

63

93

10

4

0.021

0.53

0.048

1.22

0.367

9.3

35

52

77

115

10

5

0.021

0.53

0.048

1.22

0.396

10.1

44

66

92

137

10

7

0.021

0.53

0.048

1.22

0.448

11.4

62

92

121

179

10

9

0.021

0.53

0.048

1.22

0.491

12.5

79

118

149

221

9

12

0.021

0.53

0.063

1.60

0.577

14.6

106

157

204

304

9

16

0.021

0.53

0.063

1.60

0.634

16.1

141

210

259

385

7

19

0.021

0.53

0.063

1.60

0.686

17.4

167

249

301

448

7

25

0.021

0.53

0.063

1.60

0.769

19.5

220

328

383

570

7

30

0.021

0.53

0.063

1.60

0.812

20.6

264

393

448

666

6

37

0.021

0.53

0.085

2.16

0.917

23.3

326

485

573

853

6

* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ A mpacities provided are for open cable runs, in a raceway, directly buried, or as aerial cable supported on a messenger in accordance with NEC® Articles 336.80 and 392.11,
Table 310.16 and are derated in accordance with NEC® 310.15.B.2.

Phone: 888-593-3355
www.generalcable.com

SPEC 4780

November, 2013

TC-Flex Tray Cable 14 AWG (2,5 mm ) – 10 AWG (6,0 mm )
™

²

²

UL Type WTTC 1000 V or Type TC-ER 600 V or Type MTW and c(UL) CIC/TC 600 V FT4 or CSA AWM
90°C 1000 V, Flexible, Oil Res I/II, Sunlight- and Torsion-Resistant, Flame-Retardant, -40˚C to +90˚C
Product Construction:
Conductors:

• 14 AWG (2,5 mm²) thru 10 AWG (6,0 mm²) fully
annealed flexible stranded bare copper with
Class 5 stranding per EN 60228 (IEC 60228)

Insulation:

• Polyvinyl Chloride (PVC) insulation with a clear
Polyamide (nylon) jacket per UL 83

Conductor Identification:
NOM. INS. NOM. JACKET
NOM.
THICKNESS THICKNESS CABLE O.D.

CATALOG
NUMBER

NOM. COPPER
WEIGHT

NOM. CABLE
WEIGHT

90°C
NO. OF
AMP.
COND.
@ 30°C
INC.
LBS/
LBS/
GRND. INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km AMBIENT¹
14 AWG (2,50 mm²) 46 Strands

4780.03014

3

0.021 0.53 0.048 1.22 0.375

9.5

43

65

85

126

18

4780.04014

4

0.021 0.53 0.048 1.22 0.408 10.4

58

86

106

158

18

4780.05014

5

0.021 0.53 0.048 1.22 0.442 11.2

72

108

128

190

18

4780.07014

7

0.021 0.53 0.048 1.22 0.502 12.8

101

151

170

253

18

4780.09014*

9

0.021 0.53 0.063 1.60 0.583 14.8

130

194

226

336

16

4780.12014*

12

0.021 0.53 0.063 1.60 0.647 16.4

174

259

289

429

16

4780.19014*

19

0.021 0.53 0.063 1.60 0.774 19.7

275

410

432

642

12

4780.25014*

25

0.021 0.53 0.085 2.16 0.915 23.2

362

539

587

874

12

4780.30014*

30

0.021 0.53 0.085 2.16 0.965 24.5

435

647

686

1,021

10

4780.37014*

37

0.021 0.53 0.085 2.16 1.036 26.3

536

798

826

1,229

10

4780.03012

3

0.021 0.53 0.048 1.22 0.435 11.1

72

108

123

183

25

4780.04012

4

0.021 0.53 0.048 1.22 0.476 12.1

97

144

155

231

25

4780.05012

5

0.021 0.53 0.048 1.22 0.517 13.1

121

180

188

280

25

4780.07012*

7

0.021 0.53 0.063 1.60 0.622 15.8

169

252

269

401

25

4780.09012*

9

0.021 0.53 0.063 1.60 0.684 17.4

217

323

335

498

20

4780.12012*

12

0.021 0.53 0.063 1.60 0.763 19.4

290

431

431

642

20

4780.19012*

19

0.021 0.53 0.085 2.16 0.964 24.5

459

683

689

1,025

17

4780.25012*

25

0.021 0.53 0.095 2.41 1.103 28.0

604

898

901

1,341

17

4780.30012*

30

0.021 0.53 0.095 2.41 1.164 29.6

724

1,078

1,057

1,572

14

4780.37012*

37

0.021 0.53 0.095 2.41 1.252 31.8

893

1,329

1,275

1,897

14

12 AWG (4,0 mm²) 56 Strands

10 AWG (6,0 mm²) 82 Strands
4780.03010

3

0.027 0.69 0.048 1.22 0.491 12.5

109

162

172

256

35

4780.04010

4

0.027 0.69 0.063 1.60 0.567 14.4

146

217

234

348

35

4780.05010

5

0.027 0.69 0.063 1.60 0.618 15.7

182

271

284

422

35

4780.07010*

7

0.027 0.69 0.063 1.60 0.705 17.9

255

379

381

568

35

4780.09010*

9

0.027 0.69 0.063 1.60 0.779 19.8

327

487

477

710

30

4780.12010*

12

0.027 0.69 0.085 2.16 0.915 23.2

437

650

654

973

30

4780.19010*

19

0.027 0.69 0.095 2.41 1.119 28.4

691

1,029

1,007

1,499

25

4780.25010*

25

0.027 0.69 0.095 2.41 1.259 32.0

910

1,354

1,293

1,925

20

30

0.027 0.69 0.095 2.41 1.331 33.8

1,092

1,625

1,524

2,268

20

4780.30010*

* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ A mpacities provided are for open cable runs, in a raceway, directly buried, or as aerial cable supported on a
messenger in accordance with NEC® Articles 336.80 and 392.11, Table 310.16 and are derated in accordance with
NEC® 310.15.B.2.

• Conductors are black with printed numbers and
green/yellow grounding conductor

Cable Assembly:

• Conductors cabled with non-hygroscopic fillers
to make the cable suitably round

Jacket:

• Black, flexible, flame-retardant, sunlight- and oilresistant Polyvinyl Chloride (PVC) jacket

Print:

• GENERAL CABLE® TC-FLEX™ XX/C XXAWG
(XXMM2) (UL) TC-ER TYPE THHN/THWN 90˚C DRY
75˚C WET 600 V SUN RES DIR BUR OIL RES I/II
OR MTW OR WTTC 1000 V 90˚C DRY c(UL) CIC/TC
PVC/N 90˚C FT4 --- CSA AWM I/II A/B 90˚C 1000 V
– ROHS CE – MADE IN USA DAY/MONTH/YEAR OF
MFG SEQUENTIAL FOOTAGE MARKER

Minimum Bending Radius:
• 4x O.D. for fixed installation
• 8x O.D. for flexing applications

Torsion:

• 10,000 cycles at -40°C, +/- 150° twist per meter,
cable weight compensated to 20 meters

Applications:
• In free air, raceways or direct burial
• (UL) WTTC cables for use up to 1000 V in wind
turbine generator applications in accordance with
UL Subject 6140
• (UL) TC-ER cables for use up to 600 V as power and
control cables in accordance with NEC® Article 336
• (UL) MTW cables for machine tool and wire up to
600 V as power and control cables in accordance
with UL 1063
• (CSA) CIC/TC cables for use up to 600 V in cable
trays and other applications when installed in
accordance with the Canadian Electrical Code,
Part I
• (CSA) AWM cables for use up to 1000 V as
equipment wiring in accordance with the
Canadian Electrical Code, Part I

Specifications:

Design Adherence:
• UL 66 & UL 83/CSA C22.2 No. 75-08
Thermoplastic Insulated Wires
• UL 1063/MTW Machine Tool Wire
• UL 1277 Power and Control Tray Cables
• UL 2277 Wind Turbine Tray Cables
• CSA C22.2 No. 230-09 Tray Cables
• CSA C22.2 No. 239-09 Control
and Instrumentation Cables
• CSA C22.2 No. 210-11 Appliance Wiring
Material Products
Flame Tests:
• IEEE 1202/CSA FT4
Compliances:
• Type TC-ER 90°C Dry, 75°C Wet, 600 V
• Type MTW
• Type WTTC 90°C, 1000 V
• Type CIC/TC 90°C, 600 V
• Type AWM I/II A/B, 90°C, 1000 V FT4
• RoHS Compliant

Phone: 888-593-3355
www.generalcable.com

SPEC 4785

November, 2013

TC-Flex Shielded Tray Cable 18 AWG (1,0 mm ) — 16 AWG (1,5 mm )
™

²

²

UL Type WTTC 1000 V or Type TC-ER 600 V or Type MTW and c(UL) CIC/TC 600 V FT4 or CSA AWM
90°C 1000 V, Flexible, Oil Res I/II, Sunlight- and Flame-Retardant, -40˚C to +90˚C
Product Construction:
Conductors:

• 18 AWG (1,0 mm²) and 16 AWG (1,5 mm²) fully
annealed flexible stranded bare copper with Class
5 stranding per EN 60228 (IEC 60228)

Insulation:

• Polyvinyl Chloride (PVC) insulation with a clear
Polyamide (nylon) jacket per UL 83

Conductor Identification:

• Conductors are black with printed numbers and
green/yellow grounding conductor

Cable Assembly:

• Conductors cabled with non-hygroscopic fillers
to make cable suitably round

Shield:

• Aluminum/Mylar foil shield providing 100%
coverage combined with a tinned copper braid
with 85% nom. coverage

Jacket:

• Black, flexible, flame-retardant, sunlight- and
oil-resistant Polyvinyl Chloride (PVC) jacket

Print:

• GENERAL CABLE® TC-FLEX™ XX/C XXAWG
(XXMM2) SHIELDED (UL) TC-ER TYPE TFFN 90˚C
DRY 600 V SUN RES DIR BUR OIL RES I/II OR
MTW OR WTTC 1000 V 90˚C DRY c(UL) CIC/TC
PVC/N 90˚C FT4 --- CSA AWM I/II A/B 90˚C
1000 V – ROHS CE – MADE IN USA DAY/
MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE
MARKER

CATALOG
NUMBER

NO. OF COND.
INC. GRND.

NOM. INS. THICKNESS

Minimum Bending Radius:

Specifications:

Design Adherence:
	 • UL 66 & UL 83/CSA C22.2 No. 75-08
Thermoplastic Insulated Wires
	 • UL 1063/MTW Machine Tool Wire
	 • UL 1277 Power and Control Tray Cables
	 • UL 2277 Wind Turbine Tray Cables
	 • CSA C22.2 No. 230-09 Tray Cables
	 • CSA C22.2 No. 239-09 Control and
Instrumentation Cables
	 • CSA C22.2 No. 210-11 Appliance Wiring
Material Products
Flame Tests:
	 • IEEE 1202/CSA FT4
Compliances:
	 • Type TC-ER 90°C Dry, 75°C Wet, 600 V
	 • Type MTW
	 • Type WTTC 90°C, 1000 V
	 • Type CIC/TC 90°C, 600 V
	 • Type AWM I/II A/B, 90°C, 1000 V FT4
	 • RoHS Compliant

• 4x O.D. for fixed installation
• 8x O.D. for flexing applications

Applications:

• In free air, raceways or direct burial
• (UL) WTTC cables for use up to 1000 V in wind
turbine generator applications in accordance with
UL Subject 6140
• (UL) TC-ER cables for use up to 600 V as power and
control cables in accordance with NEC® Article 336
• (UL) MTW cables for machine tool and wire up to
600 V as power and control cables in accordance
with UL 1063
• (CSA) CIC/TC cables for use up to 600 V in cable
trays and other applications when installed in
accordance with the Canadian Electrical Code,
Part I
• (CSA) AWM cables for use up to 1000 V as
equipment wiring in accordance with the
Canadian Electrical Code, Part I
• 4/C designs suitable for use in general
purpose 600 V Variable Frequency Drive (VFD)
applications2

NOM. JACKET THICKNESS
mm

NOM. CABLE O.D.
INCHES

mm

NOM. COPPER WEIGHT
LBS/1000 FT

kg/km

NOM. CABLE WEIGHT
LBS/1000 FT

kg/km

90°C AMP. @
30°C AMBIENT¹

INCHES

mm

INCHES

3

0.021

0.53

0.048

1.22

0.334

8.5

30

44

63

93

8

4

0.021

0.53

0.048

1.22

0.359

9.1

41

62

79

118

8

5

0.021

0.53

0.048

1.22

0.384

9.8

49

72

92

136

8

7

0.021

0.53

0.048

1.22

0.430

10.9

64

95

116

173

8

9

0.021

0.53

0.048

1.22

0.469

11.9

79

117

140

208

7

12

0.021

0.53

0.048

1.22

0.518

13.2

100

149

174

258

7

19

0.021

0.53

0.063

1.60

0.644

16.4

148

221

266

395

6

25

0.021

0.53

0.063

1.60

0.718

18.2

189

281

331

492

6

30

0.021

0.53

0.063

1.60

0.756

19.2

221

329

381

567

5

37

0.021

0.53

0.063

1.60

0.810

20.6

268

399

453

674

5

3

0.021

0.53

0.048

1.22

0.360

9.1

44

66

81

121

10

4

0.021

0.53

0.048

1.22

0.388

9.8

56

83

98

146

10

5

0.021

0.53

0.048

1.22

0.417

10.6

66

99

114

170

10

7

0.021

0.53

0.048

1.22

0.469

11.9

88

131

147

218

10

9

0.021

0.53

0.048

1.22

0.512

13.0

109

162

178

265

9

12

0.021

0.53

0.063

1.60

0.598

15.2

139

207

238

354

9

19

0.021

0.53

0.063

1.60

0.707

18.0

210

312

343

510

7

25

0.021

0.53

0.063

1.60

0.790

20.1

269

401

431

641

7

30

0.021

0.53

0.085

2.16

0.877

22.3

318

473

533

793

6

37

0.021

0.53

0.085

2.16

0.938

23.8

385

573

632

940

6

18 AWG (1,0 mm²) 19 Strands

4785.03018*
4785.04018
4785.05018*
4785.07018*
4785.09018*
4785.12018*
4785.19018*
4785.25018*
4785.30018*
4785.37018*

16 AWG (1,5 mm²) 28 Strands

4785.03016*
4785.04016
4785.05016*
4785.07016*
4785.09016*
4785.12016*
4785.19016*
4785.25016*
4785.30016*
4785.37016*

* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ A mpacities provided are for open cable runs, in a raceway, directly buried, or as aerial cable supported on a messenger in accordance with NEC® Articles 336.80 and 392.11,
Table 310.16 and are derated in accordance with NEC® 310.15.B.2.
2
Consult manufacturer’s specifications to verify applicability for installation with specific variable frequency drive.

Phone: 888-593-3355
www.generalcable.com

SPEC 4790

November, 2013

TC-Flex Shielded Tray Cable 14 AWG (2,5 mm ) — 2 AWG (35,0 mm )
™

²

²

UL Type WTTC 1000 V or Type TC-ER 600 V or Type MTW and c(UL) CIC/TC 600 V FT4 or CSA AWM
90°C 1000 V, Flexible, Oil Res I/II, Sunlight- and Flame-Retardant, -40˚C to +90˚C
Product Construction:
Conductors:

• 14 AWG (2,5 mm²) thru 2 AWG (35,0 mm²) fully
annealed flexible stranded bare copper with
Class 5 stranding per EN 60228 (IEC 60228)

Insulation:

• Polyvinyl Chloride (PVC) insulation with a clear
Polyamide (nylon) jacket per UL 83

CATALOG
NUMBER

NOM. INS. NOM. JACKET
NOM.
NO. OF
COND. THICKNESS THICKNESS CABLE O.D.
INC.
GRND. INCHES mm INCHES mm INCHES mm

NOM. COPPER
NOM. CABLE
WEIGHT
WEIGHT
LBS/
LBS/
1000 FT kg/km 1000 FT kg/km

90°C
AMP.
@ 30°C
AMBIENT¹

14 AWG (2,50 mm²) 46 Strands
4790.03014*

3

0.021 0.53 0.048 1.22 0.396 10.1

64

95

106

158

18

4790.04014

4

0.021 0.53 0.048 1.22 0.429 10.9

81

121

118

176

18

4790.05014*

5

0.021 0.53 0.048 1.22 0.463 11.8

98

146

139

206

18

4790.07014*

7

0.021 0.53 0.063 1.60 0.553 14.1

132

196

192

285

18

4790.09014*

9

0.021 0.53 0.063 1.60 0.604 15.3

164

244

230

342

16

4790.12014*

12

0.021 0.53 0.063 1.60 0.668 17.0

214

318

287

427

16

4790.19014*

19

0.021 0.53 0.063 1.60 0.795 20.2

325

483

412

613

12

4790.25014*

25

0.021 0.53 0.085 2.16 0.936 23.8

421

627

555

826

12

4790.30014*

30

0.021 0.53 0.085 2.16 0.986 25.0

498

741

639

951

10

4790.37014*

37

0.021 0.53 0.085 2.16 1.057 26.8

605

901

757

1,127

10

12 AWG (4,0 mm²) 56 Strands
4790.03012*

3

0.021 0.53 0.048 1.22 0.456 11.6

98

146

149

221

25

4790.04012

4

0.021 0.53 0.048 1.22 0.497 12.6

126

187

184

274

25

4790.05012*

5

0.021 0.53 0.063 1.60 0.568 14.4

153

228

235

350

25

4790.07012*

7

0.021 0.53 0.063 1.60 0.643 16.3

208

309

308

458

25

4790.09012*

9

0.021 0.53 0.063 1.60 0.705 17.9

261

388

378

562

20

4790.12012*

12

0.021 0.53 0.063 1.60 0.784 19.9

340

506

480

715

20

4790.19012*

19

0.021 0.53 0.085 2.16 0.985 25.0

525

781

754

1,122

17

4790.25012*

25

0.021 0.53 0.095 2.41 1.124 28.5

680

1,012

976

1,453

17

4790.30012*

30

0.021 0.53 0.095 2.41 1.185 30.1

807

1,201

1,138

1,693

14

4790.37012*

37

0.021 0.53 0.095 2.41 1.273 32.3

986

1,468

1,366

2,033

14

10 AWG (6,0 mm²) 82 Strands
4790.03010*

3

0.027 0.69 0.063 1.60 0.542 13.8

139

208

216

321

35

4790.04010

4

0.027 0.69 0.063 1.60 0.588 14.9

179

267

268

399

35

4790.05010*

5

0.027 0.69 0.063 1.60 0.639 16.2

219

326

321

477

35

4790.07010*

7

0.027 0.69 0.063 1.60 0.726 18.4

299

445

425

633

35

4790.09010*

9

0.027 0.69 0.063 1.60 0.800 20.3

378

562

527

784

30

4790.12010*

12

0.027 0.69 0.085 2.16 0.936 23.8

496

739

713

1,061

30

4790.19010*

19

0.027 0.69 0.095 2.41 1.145 29.1

767

1,142

1,083

1,611

25

4790.25010*

25

0.027 0.69 0.095 2.41 1.285 32.6

999

1,486

1,381

2,055

20

4790.30010*

30

0.027 0.69 0.095 2.41 1.357 34.5 1,189

1,769

1,620

2,410

20

417

412

613

55

647

632

941

75

872

867

1,290

90

1,381

1,294

1,926

130

8 AWG (10 mm²) 74 strands
4790.04008

4

0.039 0.99 0.063 1.60 0.735 18.7

280

6 AWG (16 mm²) 119 Strands
4790.04006

4

0.039 0.99 0.085 2.16 0.914 23.2

435

4 AWG (21 mm²) 413 Strands
4790.04004

4

0.050 1.27 0.095 2.41 1.094 27.8

586

2 AWG (35 mm²) 665 Strands
4790.04002

4

0.050 1.27 0.110 2.79 1.289 32.7

928

* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ A mpacities provided are for open cable runs, in a raceway, directly buried, or as aerial cable supported on a messenger
in accordance with NEC® Articles 336.80 and 392.11, Table 310.16 and are derated in accordance
with NEC® 310.15.B.2.
2
Consult manufacturer’s specifications to verify applicability for installation with specific variable frequency drive.

Conductor Identification:

• Conductors are black with printed numbers and
green/yellow grounding conductor

Cable Assembly:

• Conductors cabled with non-hygroscopic fillers
to make the cable suitably round

Shield:

• Aluminum/Mylar foil shield providing 100%
coverage in combination with a tinned copper
braid providing 85% nominal coverage

Jacket:

• Black, flexible, flame-retardant, sunlight- and
oil-resistant Polyvinyl Chloride (PVC) jacket

Print:

• GENERAL CABLE® TC-FLEX™ XX/C XXAWG
(XXMM2) SHIELDED (UL) TC-ER TYPE THHN/THWN
90˚C DRY 75˚C WET 600 V SUN RES DIR BUR OIL
RES I/II OR MTW OR WTTC 1000 V 90˚C DRY c(UL)
CIC/TC PVC/N 90˚C FT4 --- CSA AWM I/II A/B 90˚C
1000 V – ROHS CE – MADE IN USA DAY/MONTH/
YEAR OF MFG SEQUENTIAL FOOTAGE MARKER

Minimum Bending Radius:
• 4x O.D. for fixed installation
• 8x O.D. for flexing applications

Applications:

• In free air, raceways or direct burial
• (UL) WTTC cables for use up to 1000 V in wind
turbine generator applications in accordance with
UL Subject 6140
• (UL) TC-ER cables for use up to 600 V as power and
control cables in accordance with NEC® Article 336
• (UL) MTW cables for machine tool and wire up to
600 V as power and control cables in accordance
with UL 1063
• (CSA) CIC/TC cables for use up to 600 V in cable trays
and other applications when installed in accordance
with the Canadian Electrical Code, Part I
• (CSA) AWM cables for use up to 1000 V as equipment
wiring in accordance with the Canadian Electrical
Code, Part I
• 4/C designs suitable for use in general purpose
600 V Variable Frequency Drive (VFD) applications2

Specifications:

Design Adherence:
• UL 66 & UL 83/CSA C22.2 No. 75-08
Thermoplastic Insulated Wires
• UL 1063/MTW Machine Tool Wire
• UL 1277 Power and Control Tray Cables
• UL 2277 Wind Turbine Tray Cables
• CSA C22.2 No. 230-09 Tray Cables
• CSA C22.2 No. 239-09 Control and
Instrumentation Cables
• CSA C22.2 No. 210-11 Appliance Wiring
Material Products
Flame Tests:
• IEEE 1202/CSA FT 4
Compliances:
• Type TC-ER 90°C Dry, 75°C Wet, 600 V
• Type MTW
• Type WTTC 90°C, 1000 V
• Type CIC/TC 90°C, 600 V
• Type AWM I/II A/B, 90°C, 1000 V FT4
• RoHS Compliant

Phone: 888-593-3355
www.generalcable.com

SPEC 4800

July, 2010

20/10

PE/PVC/PVC, Control, Unshielded
600 V (18 AWG/16 AWG)—E-1 Color Code
Product Construction:
Conductor:

•	18 AWG and 16 AWG
•	Bare, annealed copper per ASTM B3
•	Class B stranding per ASTM B8

Insulation:

•	Lead-free, clear Polyethylene (PE)

Conductor Jacket:

•	Color-coded Polyvinyl Chloride (PVC)
•	Color-coded per ICEA Method 1, Table E-1
(includes white and green)

Cable Core:

•	Conductors are cabled with non-hygroscopic
fillers as necessary, and an overall binder tape

Overall Jacket:

•	Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE ® SUBSTATION CONTROL
CABLE X/C XXAWG CU/PE/PVC 75˚C 600 V
YEAR OF MFG SEQUENTIAL FOOTAGE MARK

Options:

•	Tinned copper conductors
•	Class C stranding per ASTM B8
•	Insulated or uninsulated ground conductors
•	Copper tape shield or aluminum/polymer tape
shield with tinned copper drain wire over cable
core
•	Bare or tinned copper braided basket weave
shield
•	Duralox® aluminum or galvanized steel interlocked
armor
•	Intergrabon® Moisture Barrier system
•	Corrugated copper tape shield longitudinally
applied

Applications:

•	For applications where environmental factors
require cable characteristics including flameretardance, resistance to chemicals, abrasion and
resistance to the harmful effects of sunlight and
weather
•	May be installed in ducts; cable trays; conduit;
Class I, Division 2 industrial hazardous locations
or continuous rigid cable supports

Features:

•	Rated at 75˚C
• Thermoplastic PE insulation provides chemical
resistance and excellent electrical properties
•	Flame-Retardant PVC conductor jacket is colorcoded for easy circuit identification
•	Flame-Retardant PVC overall jacket provides
abrasion, chemical, sunlight and weathering
resistance

Compliances:

Industry Compliances:
	 • ICEA S-73-532
Other Compliances:
	 • EPA 10 CFR, Part 261 for leachable
lead content per TCLP method

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

AVG.
COND. MINIMUM
INSULATION
NO.
SIZE
THICKNESS
OF (AWG/
COND. kcmil) INCHES mm

MINIMUM AVG.
JACKET
THICKNESS
INCHES mm

COPPER
WEIGHT
NET WEIGHT
NOMINAL
CABLE O.D.
LBS/
LBS/
INCHES mm 1000 FT kg/km 1000 FT kg/km

18 AWG MULTI-CONDUCTORS
365290* 2 Flat
2
365300*
3
389710*
4
543640*
5
365320*
7
365330*
9
365340*
12
547230*
19
365350*

18
18
18
18
18
18
18
18
18

0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025

283530* 2 Flat
2
365360*
3
365370*
4
647530*
5
283540*
7
365380*
9
365390*
12
647550*
19
365400*

16
16
16
16
16
16
16
16
16

0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025

0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.060

1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.52

.200 x .300

5.10 x 7.50

0.30
0.31
0.34
0.37
0.40
0.46
0.51
0.63

7.6
7.9
8.6
9.4
10.2
11.7
13.0
16.0

10
10
15
20
25
36
46
61
96

15
15
23
30
38
53
68
91
143

39
41
49
60
71
90
113
145
229

58
61
73
89
106
134
168
216
341

16
16
24
32
40
56
73
97
153

24
24
36
48
60
84
108
144
228

43
49
62
77
92
118
148
209
304

84
73
92
115
137
176
220
311
452

16 AWG MULTI-CONDUCTORS
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64
0.64

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060

1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52

.210 x .320

5.30 x 8.10

0.32
0.34
0.37
0.40
0.43
0.50
0.59
0.69

8.1
8.6
9.4
10.2
10.9
12.7
15.0
17.5

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

SPEC 4850
July, 2010

20/10

PE/PVC/PVC, Control, Unshielded
600 V (14 AWG—10 AWG)—E-1 Color Code
Product Construction:
Conductor:

•	14 AWG thru 10 AWG
•	Bare, annealed copper per ASTM B3
•	Class B stranding per ASTM B8

Insulation:

•	Lead-free, clear Polyethylene (PE)

Conductor Jacket:

CATALOG
NUMBER

AVG.
COND. MINIMUM
INSULATION
NO.
SIZE
THICKNESS
OF (AWG/
COND. kcmil) INCHES mm

MINIMUM AVG.
JACKET
THICKNESS
INCHES mm

COPPER
WEIGHT

NET WEIGHT
NOMINAL
CABLE O.D.
LBS/
LBS/
INCHES mm 1000 FT kg/km 1000 FT kg/km

14 AWG MULTI-CONDUCTORS
269080* 2 Flat
2
647560*
3
365410*
4
267950*
5
286130*
7
365240*
9
365430*
12
647590*
19
647600*

14
14
14
14
14
14
14
14
14

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

257750* 2 Flat
2
257770*
3
267830*
4
257730*
5
270720*
7
256750*
9
270730*
267860* 12
19
647650*

12
12
12
12
12
12
12
12
12

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

257760*
257780*
267840*
257740*
257790*
257800*
261690*
257810*
271740*

10
10
10
10
10
10
10
10
10

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52

.230 x .370 5.30 x 9.30

0.37
0.39
0.42
0.46
0.50
0.62
0.69
0.80

9.4
9.9
10.7
11.7
12.7
15.8
17.5
20.3

25
26
38
51
64
90
116
154
244

38
38
57
76
95
133
172
229
363

57
66
87
108
130
173
236
300
443

85
98
130
161
194
258
351
447
659

40
41
61
81
102
143
184
245
388

60
61
91
121
152
212
273
364
577

82
87
116
147
180
255
321
412
654

122
130
173
219
268
380
478
613
973

64
65
97
129
162
227
292
389
616

96
96
96
144
192
241
337
434
579

110
130
170
235
286
365
466
626
930

164
194
253
350
426
543
694
932
1384

12 AWG MULTI-CONDUCTORS
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03

.250 x .400 6.40 x 10.30

0.40
0.43
0.47
0.52
0.59
0.68
0.77
0.94

10.2
10.9
11.9
13.2
15.0
17.3
19.6
23.9

10 AWG MULTI-CONDUCTORS
2 Flat
2
3
4
5
7
9
12
19

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080

1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03

.270 x .450 6.90 x 11.40

0.45
0.48
0.52
0.60
0.66
0.76
0.90
1.05

11.4
12.2
13.2
15.2
16.8
19.3
22.9
26.7

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

•	Color-coded Polyvinyl Chloride (PVC)
•	Color-coded per ICEA Method 1, Table E-1
(includes white and green)

Cable Core:

•	Conductors are cabled with non-hygroscopic
fillers as necessary, and an overall binder tape

Overall Jacket:

•	Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE ® SUBSTATION CONTROL
CABLE X/C XXAWG CU/PE/PVC 75˚C 600 V
YEAR OF MFG SEQUENTIAL FOOTAGE MARK

Options:

•	Tinned copper conductors
•	Class C stranding per ASTM B8
•	Insulated or uninsulated ground conductors
•	Copper tape shield or aluminum/polymer tape
shield with tinned copper drain wire over cable
core
•	Bare or tinned copper braided basket weave
shield
•	Duralox® aluminum or galvanized steel interlocked
armor
•	Intergrabon® Moisture Barrier system
•	Corrugated copper tape shield longitudinally
applied

Applications:

•	For applications where environmental factors
require cable characteristics including flameretardance, resistance to chemicals, abrasion and
resistance to the harmful effects of sunlight and
weather
•	May be installed in ducts; cable trays; conduit;
Class I, Division 2 industrial hazardous locations
or continuous rigid cable supports

Features:

•	Rated at 75˚C
• Thermoplastic PE insulation provides chemical
resistance and excellent electrical properties
•	Flame-retardant PVC conductor jacket is colorcoded for easy circuit identification
•	Flame-retardant PVC overall jacket provides
abrasion, chemical, sunlight and weathering
resistance

Compliances:

Industry Compliances:
	 • ICEA S-73-532
Other Compliances:
	 • EPA 10 CFR, Part 261 for leachable
lead content per TCLP method

Phone: 888-593-3355
www.generalcable.com

SPEC 4900
October, 2012

GenFree

®

XLPE/LSZH, Control
600 V, UL Type TC-LS-ER1—E-2 Color Code
Product Construction:
Conductor:

• 14 AWG thru 10 AWG stranded tinned copper per
ASTM B33
• Class B stranding per ASTM B8

Insulation:

• Lead-free, flame-retardant, low-smoke
Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1, Table E-2 (does
not include white or green)

Jacket:

• Lead-free, flame-retardant, sunlight-resistant,
Low-Smoke, Zero-Halogen Polyolefin (LSZH)

Print

• GENERAL CABLE ® (PLANT OF MFG) GENFREE®
XX/C XXAWG XLPE/LSZH (UL) TYPE TC-LS-ER
XHHW-2 CDRS 90°C WET OR DRY 600 V DIR
BUR SUN RES ROHS DAY/MONTH/YEAR OF
MFG SEQUENTIAL FOOTAGE MARK

Options:

• Bare copper conductor
• E-1 Color Code
• Overall shielded multi-conductor
• Other constructions available upon request

Applications:

• In free air, raceways, aerial or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC
• Permitted for Exposed Run (ER) use in
accordance with the NEC for 3 or more
conductors

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical and electrical properties
• Excellent moisture resistance
• Excellent resistance to compression and impact
•	Chemical-resistant
• Low coefficient of friction for easy pulling
• Sunlight- and weather-resistant
• Meets cold bend test at -30˚C
• Low-Smoke, Zero-Halogen jacket is
environmentally safe
• Low-Smoke, Zero-Halogen jacket reduces the
amount of toxic and corrosive gases emitted
during combustion, providing a safer environment
for personnel and equipment during the hazards
of fire
• Meets the crush and impact requirements of Type
MC cable for 3 or more conductors

Compliances:

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC-LS-ER, UL File # E57179
	 • UL 1581
	 • ICEA S-73-532/NEMA WC57
	 • ICEA T-33-655
	 • RoHS Compliant
Flame Test Compliances:
	 • UL 1581/UL 2556
	 • UL 1685 Vertical Flame Test
	 • IEEE 1202
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

14 AWG MULTI-CONDUCTORS
394280 2 Flat
2
394290*
3
394300
4
394310
5
394320
7
394330
9
394340
12
394350
19
394360
394370* 25
394380* 30
394390* 37

14
14
14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

394400
394410*
3944202
394430
394440
394450
394460
394470
394480
394490
394500*
394510*
394520*

2 Flat
2
3+ Grnd
3
4
5
7
9
12
19
25
30
37

12
12
12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

394530 2 Flat
2
394540*
3945502 3+ Grnd
3
394560
4
394570
5
394580
7
394590
9
394600
12
394610

10
10
10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

.365 x .230 9.30 x 5.80

0.370
0.390
0.425
0.465
0.505
0.620
0.700
0.815
0.935
1.030
1.110

9.40
9.91
10.80
11.81
12.83
15.75
17.78
20.70
23.75
26.16
28.19

26
26
39
53
66
92
118
158
250
323
387
466

38
39
59
78
98
137
176
235
372
481
576
694

61
71
92
115
139
173
240
301
468
624
747
875

91
106
137
171
207
257
357
448
696
929
1112
1302

40
41
85
64
85
106
149
191
247
391
515
618
762

60
82 122
61
94 140
127 148 220
95 124 185
127 157 234
158 191 284
221 268 399
285 337 502
368 428 637
582 688 1024
767 854 1271
920 1002 1491
1134 1240 1845

64
65
134
100
134
167
234
295
402

95
97
199
150
199
249
349
440
598

12 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

.400 x .245 10.20 x 6.20

0.410
0.435
0.435
0.475
0.520
0.595
0.695
0.765
0.940
1.095
1.150
1.240

10.41
11.05
11.05
12.07
13.21
15.11
17.65
19.43
23.88
27.81
29.21
31.50

10 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03

.445 x .270 11.30 x 6.90

0.455
0.485
0.485
0.560
0.615
0.670
0.760
0.905

11.56
12.32
12.32
14.22
15.62
17.02
19.30
22.99

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as -ER for Exposed Run applications of 3 or more conductors as defined by the NEC.
² This construction does not require an -ER mark.

113
128
225
172
234
284
381
464
651

168
190
335
256
348
423
567
691
696

SPEC 4925
October, 2012

GenFree

®

XLPE/LSZH, Control, Shielded
600 V, UL Type TC-LS-ER1, Overall Shielded—E-2 Color Code
Product Construction:
Conductor:

• 16 AWG thru 10 AWG stranded tinned copper per
ASTM B33
• Class B stranding per ASTM B8

Insulation:

• Lead-free, flame-retardant, low-smoke
Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1, Table E-2
(does not include white or green)

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

OVERALL SHIELDED MULTI-CONDUCTORS
16 AWG CONDUCTORS
394960*
394630*

2
3

16
16

7/.0192 0.025 0.64 0.045 1.14 0.320 8.13
7/.0192 0.025 0.64 0.045 1.14 0.335 8.51

19
27

28
40

52
66

77
98

43
63
82
101
140
180
238
375
484
579
696

74
95
118
142
176
243
304
471
627
750
878

110
141
176
211
262
362
452
701
933
1116
1307

64
98
129
162
225
287
371
585
769
923
1137

97
127
160
194
271
340
431
691
857
1005
1243

144
189
238
289
403
506
641
1028
1275
1496
1850

101
155
202
253
353
443
601

131
175
237
287
384
467
654

195
260
353
427
571
695
973

OVERALL SHIELDED MULTI-CONDUCTORS
14 AWG CONDUCTORS
394640*
394650*
394660*
394670*
394680*
394690*
394700*
394710*
394720*
394730*
394740*

2
3
4
5
7
9
12
19
25
30
37

14
14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

0.375
0.395
0.430
0.470
0.510
0.625
0.705
0.820
0.940
1.035
1.115

9.53 29
10.03 42
10.92 55
11.94 68
12.95 94
15.88 121
17.91 160
20.83 252
25.53 325
26.29 389
28.32 468

OVERALL SHIELDED MULTI-CONDUCTORS
12 AWG CONDUCTORS
394750*
394760*
394770*
394780*
394790*
394800*
394810*
394820*
394830*
394840*
394850*

2
3
4
5
7
9
12
19
25
30
37

12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

0.415
0.440
0.480
0.525
0.600
0.700
0.770
0.945
1.100
1.155
1.245

10.45 43
11.18 66
12.19 87
13.34 108
15.24 151
17.78 193
19.56 249
24.00 393
27.94 517
29.80 620
31.62 764

OVERALL SHIELDED MULTI-CONDUCTORS
10 AWG CONDUCTORS
394860*
394870*
394880*
394890*
394900*
394910*
394920*

2
3
4
5
7
9
12

10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.52
1.52
1.52
1.52
2.03

0.460
0.490
0.565
0.620
0.675
0.765
0.910

11.68
12.45
14.35
15.75
17.15
19.43
23.11

68
103
136
170
237
298
404

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Approved as -ER for Exposed Run applications of 3 or more conductors as defined by the NEC.

Shield:

Overall shielded multi-conductor cable
• Overall shield is Flexfoil® aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

• Lead-free, flame-retardant, sunlight-resistant,
Low-Smoke, Zero-Halogen Polyolefin (LSZH)

Print

• GENERAL CABLE® (PLANT OF MFG) SHIELDED
GENFREE® XX/C XXAWG XLPE/LSZH (UL) TYPE
TC-LS-ER XHHW-2 CDRS 90˚C WET OR DRY 600
V DIR BUR SUN RES ROHS DAY/MONTH/YEAR
OF MFG SEQUENTIAL FOOTAGE MARK

Options:

• Bare copper conductor
• E-1 Color Code
• Unshielded multi-conductors
• Other constructions available upon request

Applications:

• In free air, raceway, aerial and direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC
• Permitted for Exposed Run (ER) use in
accordance with the NEC for 3 or more
conductors

Features:

• Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical and electrical properties
• Excellent moisture resistance
• Excellent resistance to compression and impact
•	Chemical-resistant
• Low coefficient of friction for easy pulling
• Sunlight- and weather-resistant
• Meets cold bend test at -30˚C
• Low-Smoke, Zero-Halogen jacket is
environmentally safe
• Low-Smoke, Zero-Halogen jacket reduces the
amount of toxic and corrosive gases emitted
during combustion, providing a safer environment
for personnel and equipment during the hazards
of fire
• Meets the crush and impact requirements of Type
MC cable for 3 or more conductors

Compliances:

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC-LS-ER, UL File # E57179
	 • UL 1581/UL 2556
	 • ICEA S-73-532/NEMA WC57
	 • ICEA T-33-655
	 • RoHS Compliant
Flame Test Compliances:
	 • UL 1581/UL 2556
	 • UL 1685 Vertical Flame Test
	 • IEEE 1202
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

SPEC 4950
October, 2012

GenFree

®

XLPE/LSZH, Low-Voltage Power, Unshielded
600 V, UL Type TC-LS-ER—Method 4 Color Code
Product Construction:
Conductor:

•	14 AWG thru 750 kcmil tinned annealed
copper per ASTM B33
•	Class B stranding per ASTM B8

Insulation:

• Lead-free, flame-retardant, low-smoke
Cross-linked Polyethylene (XLPE)
•	Color-coded per ICEA Method 4; individual
conductors colored black with conductor number
surface printed in contrasting ink

Applications:

Features (cont’d.):

•	In free air, raceways, aerial or direct burial
•	In wet or dry locations
•	Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC
•	Permitted for Exposed Run (ER) use in
accordance with the NEC

Ground:

•	Uninsulated bare annealed copper per ASTM B3
•	Class B stranding per ASTM B8

Jacket:

• Lead-free, flame-retardant, sunlight-resistant,
Low-Smoke, Zero-Halogen Polyolefin (LSZH)

• Low-Smoke, Zero-Halogen jacket reduces the
amount of toxic and corrosive gases emitted during
combustion, providing a safer environment for
personnel and equipment during the hazards of fire

Compliances:

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC-LS-ER, UL File # E57179
	 • UL 1581/UL 2556
	 • ICEA S-95-658/NEMA WC70
	 • ICEA T-33-655
	 • RoHS Compliant
Flame Test Compliances:
	 • UL 1581/UL 2556
	 • UL 1685 Vertical Flame Test
	 • IEEE 1202
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Features:

•	Rated at 90˚C wet or dry
• Ripcord applied to all cables with jacket thickness
of 60 mils or less
• Excellent physical, thermal and electrical
properties
•	Excellent moisture resistance
•	Excellent resistance to crush, compression and
impact
•	Chemical-resistant
•	Low coefficient of friction for easy pulling
•	Sunlight- and weather-resistant
•	Meets cold bend test at -30˚C
• Low-Smoke, Zero-Halogen jacket is
environmentally safe

Print:

•	GENERAL CABLE® (PLANT OF MFG) GENFREE®
XX/C XXAWG XLPE/LSZH (UL) TYPE TC-LS-ER
XHHW-2 CDRS 90˚C WET OR DRY 600 V DIR
BUR SUN RES ROHS DAY/MONTH/YEAR OF
MFG SEQUENTIAL FOOTAGE MARK

	Options:

•	Bare copper conductor
•	E-1 or E-2 Color Code
•	Insulated ground conductors
•	Overall shielded multi-conductors
• Other constructions available upon request

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

CATALOG
NUMBER

NO. OF
COND.

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

GROUND
WIRE SIZE
(AWG)

MINIMUM AVG.
INSULATION
THICKNESS
INCHES

mm

MINIMUM AVG.
JACKET THICKNESS NOMINAL CABLE O.D.
INCHES

mm

INCHES

mm

COPPER
WEIGHT
LBS/
1000 FT kg/km

NET WEIGHT
LBS/
1000 FT kg/km

14 AWG - 750 kcmil MULTI-CONDUCTORS
394930*
394940*
394950*
14428.030800
14428.040800*
14428.030600
14428.040600*
14428.030400
14428.040400*
14428.030200
14428.040200*
14428.030100*
14428.040100*
14428.035100
14428.045100*
14428.035200
14428.045200*
14428.035300*
14428.045300*
14428.035400
14428.045400*
14428.036000*
14428.046000*
14428.036200*
14428.046200*
14428.036500*
14428.046500*
14428.037000*
14428.047000*

3
3
3
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4

14
12
10
8
8
6
6
4
4
2
2
1
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
250
250
350
350
500
500
750
750

7/.0242
7/.0305
7/.0385
7/.0486
7/.0486
7/.0612
7/.0612
7/.0772
7/.0772
7/.0974
7/.0974
19/.0664
19/.0664
19/.0745
19/.0745
19/.0837
19/.0837
19/.0940
19/.0940
19/.1055
19/.1055
37/.0822
37/.0822
37/.0973
37/.0973
37/.1162
37/.1162
61/.1109
61/.1109

14
12
10
10
10
8
8
8
8
6
6
6
6
6
6
6
6
4
4
4
4
4
4
3
3
2
2
1
1

0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.065
0.065
0.065
0.080
0.080

0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.65
1.65
1.65
1.65
1.65
1.65
2.03
2.03

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.140
0.140

1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79
2.79
2.79
2.79
3.56
3.56

0.390
0.435
0.485
0.655
0.720
0.740
0.790
0.880
0.950
1.010
1.090
1.120
1.235
1.225
1.330
1.300
1.440
1.420
1.570
1.540
1.790
1.760
1.915
1.960
2.165
2.245
2.475
2.810
3.115

9.91
11.05
12.32
16.64
18.29
18.80
20.07
22.35
24.13
25.65
27.69
28.45
31.37
31.12
33.78
33.02
36.58
36.07
39.88
39.12
45.47
44.70
48.64
49.78
54.99
57.02
62.87
71.37
79.12

55
87
124
190
242
297
384
442
578
703
919
872
1136
1069
1413
1340
1760
1717
2245
2130
2796
2494
3282
3474
4577
4934
6509
7278
9712

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

82
129
184
283
360
442
571
658
861
1046
1368
1298
1691
1591
2103
1994
2619
2555
3341
3170
4161
3712
4884
5170
6811
7343
9687
10831
14453

118
160
194
314
393
456
561
642
822
979
1235
1021
1521
1439
1820
1720
2208
2176
2788
2614
3495
3184
4019
4187
5436
5847
7607
9145
11805

176
238
289
467
585
679
835
955
1223
1457
1838
1594
2264
2142
2709
2560
3286
3238
3405
3890
5201
4738
5981
6231
8090
8702
11321
13610
17569

		
Industrial Cables		

Date of Issue 06/13
Section 5

600 V – 2 kV Industrial Power Cables
SPECIFICATION NO.

PRODUCT DESCRIPTION

REVISION DATE

5050†

DuraSheath

EPR/XL-CPE, Low-Voltage Power, Unshielded
600 V, UL Type RHH/RHW-2/USE-2

Mar. 2012

5075

GenFree® II

LSZH XLPO/LSZH XLPO, Low-Voltage Power, Unshielded
600 V, UL Type RHH/RHW-2/USE-2

Jun. 2013

5100

Unicon® FREP®

FR-EPR, Low-Voltage Power, Unshielded
600 V, UL Type RHH/RHW-2/USE-2

Jan. 2010

5125

GenFree® II

LSZH XLPO, Low-Voltage Power, Unshielded
600 V, UL Type XHHW-2

Jun. 2013

5150†

XHHW-2 VW-1

XLPE, Control and Low-Voltage Power
600 V, UL Type SIS/XHHW-2, VW-1 Rated

Oct. 2012

5175†

XHHW-2 CT

XLPE, Low-Voltage Power
600 V, UL Type XHHW-2, CT Rated, Single Conductor, Copper

Jan. 2013

5250†

Unicon® XLPE

XLPE, Low-Voltage Power
600 V, UL Type RHH/RHW-2/USE-2

Oct. 2012

5275

GenFree® II

LSZH XLPO, Low-Voltage Power, Unshielded
600 V, UL Type RHH/RHW-2/USE-2

Jun. 2013

5290†

THHN/THWN-2

PVC, Low-Voltage Power
600 V, UL Type THHN/THWN-2, Single Conductor, Copper

Oct. 2012

5300

Super Vu-Tron®

EPR/CPE, Diesel Locomotive Cable
90°C, 2000 V, DLO, UL Type RHH/RHW, 600 V, CSA Type R90, 1000 V

Mar. 2012

5310†

®

Diesel
2000 Volts (EPR/XL-CPE), UL RHH/RHW-2 2000 V and c(UL) RW90 1000 V
Locomotive Cable Flexible, Oil-, Sunlight- and Ozone-Resistant, Flame-Retardant, -40°C to 90°C

May 2012

5350†

GenFree® LSZH

DISCONTINUED

Sept. 2013

5400

GenFree® LSZH

DISCONTINUED

Sept. 2013

5700†

RHH/RHW-2

5790

XLPE, Low-Voltage Power, Unshielded
2000 V, UL Type RHH/RHW-2, Single Conductor, Aluminum

Mar. 2012

SunGen®
Global

XLPE/LSZH XLPO, Photovoltaic Wire, TÜV 2 pfg
1169/08.2007 PV1-F AC Uo/U 0.6/1 kV, UL 4703, PV Wire 2000 V

May 2012

5800†

SunGen®

Dual-Layer EPR/XL-CPE, Photovoltaic Wire
600 V, UL Type PV/USE-2/RHH or RHW-2, Single Conductor, Copper

May 2012

5800A

SunGen®

Dual-Layer EPR/XL-CPE, Photovoltaic Wire
600 V, UL Type PV/USE-2/RHH or RHW-2, Single Conductor, Aluminum

Oct. 2012

5810†

SunGen®

Dual-Layer EPR/XL-CPE, Photovoltaic Wire
2000 V, UL Type PV/RHH or RHW-2 or 600 V USE-2, Single Conductor, Copper

May 2012

†Indicates

these products are stocked by General Cable

Phone: 888-593-3355
www.generalcable.com

Date of Issue 06/13
Section 5 	

Industrial Cables

600 V – 2 kV Industrial Power Cables
SPECIFICATION NO.

PRODUCT DESCRIPTION

REVISION DATE

5810A

SunGen

Dual-Layer EPR/XL-CPE, Photovoltaic Wire
2000 V, UL Type PV/RHH or RHW-2 or 600 V USE-2, Single Conductor, Aluminum

Oct. 2012

5840†

SunGen®

XLPE, Photovoltaic Wire
600 V, UL Type PV/USE-2 or 2000 V RHH or RHW-2 or CSA RPVU90
1000 V, Single Conductor, Copper

May 2012

5840A

SunGen®

XLPE, Photovoltaic Wire
600 V, UL Type PV/USE-2 or 2000 V RHH or RHW-2 or CSA RPVU90
1000 V, Single Conductor, Aluminum

Oct. 2012

5845†

SunGen® IC

XLPE, Photovoltaic Wire
600 V, UL Type PV/USE-2 or 2000 V RHH or RHW-2 or CSA RPVU90
1000 V, Single Conductor, Copper

May 2012

5850†

SunGen®

XLPE, Photovoltaic Wire
2000 V, UL Type PV/RHH or RHW-2 or 600 V USE-2 or CSA RPVU90
1000 V, Single Conductor, Copper

May 2012

5850A

SunGen®

XLPE, Photovoltaic Wire
2000 V, UL Type PV/RHH or RHW-2 or 600 V USE-2 or CSA RPVU90
1000 V, Single Conductor, Aluminum

Oct. 2012

5855†

SunGen® IC

XLPE, Photovoltaic Wire
2000 V, UL Type PV/RHH or RHW-2 or 600 V USE-2 or CSA RPVU90
1000 V, Single Conductor, Copper

May 2012

5880†

SunGen® MI

XLPE/PVC, AC Micro-Inverter Cable
600 V, UL Type TC-ER

May 2012

5890†

SunGen® MI-LS

XLPO/LSZH, AC Micro-Inverter Cable
600 V, UL Type TC-LS-ER

May 2012

®

†Indicates

these products are stocked by General Cable

Phone: 888-593-3355
www.generalcable.com

SPEC 5050
March, 2012

DuraSheath

®

EPR/XL-CPE, Low-Voltage Power, Unshielded
600 V, UL Type RHH/RHW-2/USE-2
Compliances:

Product Construction:
Conductor:

Industry Compliances:
• National Electric Code (NEC)
• ICEA S-95-658/NEMA WC70
• “FOR CT USE” on 1/0 AWG and larger
in accordance with the NEC
• UL 44 Type RHH/RHW-2, UL File # E90494
• UL 854 Type USE-2, UL File # E90499
Flame Test Compliances:
	 • UL 1581 VW-1
	 • IEEE 1202/CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable
	 • RoHS Compliant

Options:

•	Colored jackets available upon request
•	2000 V rated cables

•	14 AWG thru 1000 kcmil tin-coated copper
compressed Class B stranding per ASTM B33
and B8

Applications:

•	Ideally suited for use in a broad range of
commercial, industrial and utility applications
where reliability is a major concern and where
maximum performance will be demanded
•	In free air, raceways or direct burial
•	For use in aerial, conduit, open tray and
underground duct/installations

Insulation:

•	Lead-free Ethylene Propylene Rubber (EPR)
colored to contrast with jacket

Jacket:

•	Lead-free Cross-linked Chlorinated Polyethylene
(XL-CPE), black

Print:

CATALOG
NUMBER

COND.
STRAND

14511.411400
14511.411200
14511.411000
14511.410800
14511.410600
14511.410400
14511.710200
14511.715100
14511.715200
14511.715400
14511.716000
14511.716200
14511.716500
14511.717000
14511.717500

14
12
10
8
6
4
2
1/0
2/0
4/0
250
350
500
750
1000

7/.0242
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772
7/.0974
19/.0740
19/.0837
19/.1055
37/.0822
37/.0973
37/.1162
61/.1109
61/.1280

• Material cut to length and shipped on
non-returnable wood reels

Features:

•	Rated at 90˚C wet or dry
• Deformation-resistant at high temperatures
• Excellent moisture resistance, exceeds UL 44
• Stable electrical properties over a broad
temperature range
•	Excellent flexibility at low temperatures; suitable
for installation in sub-zero conditions
• Extra-tough, mechanically rugged composite
insulation and jacket construction
• Resistant to most oils and chemicals
• UV/sunlight-resistant
• Meets UL 44 cold bend test at -40˚C

For 1 AWG and smaller:
•	GENERAL CABLE ® MI DURASHEATH® TYPE
USE-2 OR RHH OR RHW-2 VW-1 (AWG SIZE)
(MM SIZE) EP 600 VOLTS SUN RES (UL) ROHS
MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE
MARK
For 1/0 AWG and larger:
•	GENERAL CABLE ® MI DURASHEATH® LL TYPE
USE-2 OR RHH OR RHW-2 VW-1 (AWG SIZE)
(MM SIZE) EP 600 VOLTS SUN RES FOR CT USE
(UL) ROHS MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

COND.
SIZE
(AWG/
kcmil)

Packaging:

MINIMUM AVG.
INSULATION
THICKNESS
DIAMETER
INCHES
mm
INCHES
mm

NOMINAL COND.
DIAMETER
INCHES
mm

MINIMUM AVG.
JACKET
THICKNESS
DIAMETER
INCHES
mm
INCHES
mm

COPPER
WEIGHT

NET WEIGHT

LBS/
1000 FT

kg/
km

LBS/
1000 FT

kg/
km

13
20
32
50
81
129
205
326
411
653
772
1081
1542
2316
3086

19
30
48
75
121
192
305
485
612
972
1149
1609
2295
3447
4593

24
33
48
77
122
178
265
422
518
785
960
1299
1803
2664
3989

36
49
71
115
182
265
394
628
771
1168
1429
1933
2683
3965
5936

14 AWG - 1000 kcmil CONDUCTORS
0.07
0.09
0.12
0.15
0.18
0.23
0.29
0.37
0.41
0.52
0.56
0.67
0.80
0.98
1.13

1.78
2.29
3.05
3.81
4.57
5.84
7.37
9.40
10.41
13.21
14.22
17.02
20.32
24.89
28.70

0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.065
0.065
0.065
0.080
0.080

0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.65
1.65
1.65
2.03
2.03

0.14
0.16
0.18
0.24
0.28
0.33
0.39
0.48
0.53
0.64
0.70
0.81
0.94
1.15
1.31

3.56
4.06
4.57
6.10
7.11
8.38
9.91
12.19
13.46
16.26
17.78
20.57
23.88
29.21
33.27

0.015
0.015
0.015
0.015
0.030
0.030
0.030
0.045
0.045
0.045
0.065
0.065
0.065
0.065
0.065

0.38
0.38
0.38
0.38
0.76
0.76
0.76
1.14
1.14
1.14
1.65
1.65
1.65
1.65
1.65

0.17
0.19
0.21
0.28
0.35
0.39
0.46
0.58
0.63
0.74
0.85
0.96
1.09
1.31
1.46

4.32
4.83
5.33
7.11
8.89
9.91
11.68
14.73
16.00
18.80
21.59
24.38
27.69
33.27
37.08

Dimensions and weights are nominal; subject to industry tolerances.

Phone: 888-593-3355
www.generalcable.com

SPEC 5075

June, 2013

GenFree II
®

LSZH XLPO/LSZH XLPO, Low-Voltage Power, Unshielded
600 V, UL Type RHH/RHW-2/USE-2
Product Construction:
Conductor:

•	14 AWG thru 1000 kcmil compressed tinned copper
per ASTM B33
•	Class B stranding per ASTM B8

Insulation:

•	Composite Low-Smoke, Zero-Halogen Cross-linked
Polyolefin (LSZH XLPO) colored for contrast with
black Low-Smoke, Zero-Halogen Cross-linked
Polyolefin (LSZH XLPO)

Features:

Print:

•	GENERAL CABLE® (PLANT OF MFG) GENFREE® II
17 FREE™ LSZH TYPE USE-2 OR RHH OR RHW-2
(SIZE) 600 V OIL RES I SUN RES -40C ST1*
FOR CT USE* (UL) DAY/MONTH/YEAR OF MFG
SEQUENTIALFOOTAGE MARK
* “ST1” and “FOR CT USE” on 1/0 AWG and larger

Options:
•	2 kV version
•	Bare copper conductor
•	Other stranding available

Applications:

•	For use in closed environments or populated spaces
such as auditoriums, arenas and health facilities
where more stringent customer specifications for
smoke and halogen-free materials are desired
•	Ideally suited for use in a broad range of
commercial, industrial and utility applications
where reliability is a major concern, where
maximum performance will be demanded and
where space is limited
•	For use in free air, raceways or direct burial in
accordance with NEC

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

14711.411400
14711.411200
14711.411000
14711.410800
14711.410600
14711.410400
14711.710200
14711.715100
14711.715200
14711.715400
14711.716000
14711.716200
14711.716500
14711.717000
14711.717500*

14
12
10
8
6
4
2
1/0
2/0
4/0
250
350
500
750
1000

7/.0242
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772
7/.0974
19/.0740
19/.0837
19/.1055
37/.0822
37/.0973
37/.1162
61/.1109
61/.1280

NOMINAL COND.
DIAMETER
INCHES
mm

Compliances:

•	Rated at 90˚C wet or dry
•	Low-Smoke, Zero-Halogen insulation system
•	Extra-tough, mechanically rugged composite
insulation construction
• Low Friction for easy pulling on 8 AWG and larger
•	Excellent electrical, thermal and physical properties
•	Excellent moisture resistance, exceeding UL 44
requirements
•	Excellent resistance to crush, compression cuts
and heat deformation
•	Excellent flame resistance
•	Resistant to most oils and chemicals
•	UV/sunlight-resistant
•	Rated ST-1 for Limited Smoke per UL 44 on sizes
1/0 AWG and larger
•	Stable electrical properties over a broad
temperature range
•	Excellent low temperature cold bend characteristics,
meets cold bend and cold impact test at -40˚C

Industry Compliances:
•	National Electrical Code (NEC)
•	 “FOR CT USE” on 1/0 AWG and larger in
accordance with NEC
•	UL 44 Type RHH/RHW-2, UL File # E90494
•	UL 854 Type USE-2, UL File # E90499
•	Limited Smoke rating per UL 44 and UL 1685
•	ICEA T-33-655 smoke, halogen and acid gas
requirements
•	ICEA S-95-658/NEMA WC70
Flame Test Compliances:
•	For 1/0 AWG and larger: IEEE 383, IEEE 1202/CSA FT4
•	UL 1685
Other Compliances:
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP
•	OSHA Acceptable
•	RoHS Compliant

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

MINIMUM AVG.
INSULATION
THICKNESS
DIAMETER
INCHES
mm
INCHES
mm

MINIMUM AVG.
JACKET
THICKNESS
DIAMETER
INCHES
mm
INCHES
mm

COPPER
WEIGHT

NET WEIGHT

LBS/
1000 FT

kg/
km

LBS/
1000 FT

kg/
km

13
20
32
50
81
129
205
326
411
653
772
1081
1542
2316
3806

19
30
48
75
121
192
305
485
612
972
1149
1609
2295
3447
5664

24
33
48
77
122
178
265
422
518
785
960
1299
1803
2664
3989

36
49
71
115
182
265
394
628
771
1168
1429
1933
2683
3965
5936

14 AWG - 1000 kcmil CONDUCTORS
0.07
0.09
0.12
0.15
0.18
0.23
0.29
0.37
0.41
0.52
0.56
0.67
0.80
0.97
1.13

1.78
2.29
3.05
3.81
4.57
5.84
7.37
9.40
10.41
13.21
14.22
17.02
20.32
24.62
28.70

0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.065
0.065
0.065
0.080
0.080

0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.65
1.65
1.65
2.03
2.03

0.14
0.16
0.18
0.24
0.28
0.33
0.39
0.48
0.53
0.64
0.70
0.81
0.94
1.15
1.31

3.56
4.06
4.57
6.10
7.11
8.38
9.91
12.19
13.46
16.26
17.78
20.57
23.88
29.21
33.27

0.015
0.015
0.015
0.015
0.030
0.030
0.030
0.045
0.045
0.045
0.065
0.065
0.065
0.065
0.065

0.38
0.38
0.38
0.38
0.76
0.76
0.76
1.14
1.14
1.14
1.65
1.65
1.65
1.65
1.65

0.17
0.19
0.21
0.28
0.35
0.39
0.46
0.58
0.63
0.74
0.85
0.96
1.09
1.31
1.46

4.32
4.83
5.33
7.11
8.89
9.91
11.68
14.73
16.00
18.80
21.59
24.38
27.69
33.27
37.08

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Going Green with General Cable
General Cable has accelerated its environmental commitment, addressing its green alternative approach by identifying greener opportunities
and promoting green cabling solutions wherever feasible. This includes promoting our existing green products, partnering with key customers
in their green endeavors, identifying and providing for green product gaps, and participating as a member of the United States Green Building
Council (USGBC) and collaborative ventures such as the Green Suppliers Network (GSN).

Phone: 888-593-3355
www.generalcable.com

SPEC 5100

January, 2010

Unicon FREP
®

®

FR-EPR, Low-Voltage Power, Unshielded
600 V, UL Type RHH/RHW-2/USE-2
Compliances:

Product Construction:
Conductor:

Industry Compliances:
	 • National Electrical Code (NEC)
	 • UL 44 Type RHH/RHW-2, UL File # E90494
	 • UL 854 Type USE-2, UL File # E90499
	 • ICEA S-95-658/NEMA WC70
	 • “FOR CT USE” on 1/0 AWG and larger in
accordance with NEC
	 • UL Listed VW-1
Flame Test Compliances:
	 • UL 1581 VW-1
	 • For 1/0 AWG and larger: IEEE 383, IEEE 1202/
CSA FT4, ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Applications:

•	14 AWG thru 1000 kcmil stranded annealed
	 bare copper compressed Class B stranding per
ASTM B8

Insulation:

•	Flame-retardant Ethylene Propylene
Rubber (EPR)

Features:

Print:

•	GENERAL CABLE (PLANT OF MFG) UNICON
FREP ® TYPE USE-2 OR RHH OR RHW-2
VW-1 SIZE (AWG OR KCMIL) 600 VOLTS
SUN RES FOR CT USE (UL) DAY/MONTH/YEAR
OF MFG SEQUENTIAL FOOTAGE MARK
®

®

* Sizes smaller than 1/0 AWG do not include
“FOR CT USE”

Options:

•	2 kV version
•	Tinned copper conductor
•	Class C stranding
•	Unicon® XLPE—flame-retardant Cross-linked
Polyethylene (XLPE) insulation
•	Other constructions available upon request

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

14101.211400*
14101.211200*
14101.211000*
14101.210800*
14101.210600*
14101.210400*
14101.210200*
14101.215100*
14101.215200*
14101.215400*
14101.216000*
14101.216200*
14101.216500*
14101.217000*
14101.217500*

14
12
10
8
6
4
2
1/0
2/0
4/0
250
350
500
750
1000

7/.0242
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772
7/.0974
19/.0740
19/.0837
19/.1055
37/.0822
37/.0973
37/.1162
61/.1109
61/.1280

•	Ideally suited for use in broad range of
commercial, industrial and utility applications
where reliability is the major concern, where
maximum performance will be demanded and
where space is limited
•	In free air, raceways or direct burial in accordance
with NEC

Packaging:

•	Material cut to length and shipped on nonreturnable wood reels

•	Rated at 90˚C wet or dry
• Smaller cable diameter
•	Excellent electrical, thermal and physical
properties
•	Excellent resistance to moisture
•	Excellent resistance to crush, compression cuts
and heat deformation
•	Excellent flame resistance
•	Excellent low temperature cold bend
characteristics
•	Meets cold bend test at -25˚C

NOMINAL COND.
DIAMETER
INCHES
mm

MINIMUM AVG.
INSULATION THICKNESS
INCHES
mm

NOMINAL CABLE
O.D.
INCHES
mm

COPPER
WEIGHT
LBS/
1000 FT
13
20
32
50
81
129
205
326
411
653
772
1081
1542
2316
3086

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

19
30
48
75
121
192
305
485
612
972
1149
1609
2295
3447
4593

24
33
48
78
114
169
254
402
500
759
905
1235
1728
2573
3402

36
49
71
116
170
252
378
598
744
1130
1347
1838
2572
3829
5063

14 AWG - 1000 kcmil CONDUCTORS
0.07
0.09
0.12
0.15
0.18
0.23
0.29
0.37
0.41
0.52
0.56
0.67
0.80
0.98
1.13

1.78
2.29
3.05
3.81
4.57
5.84
7.37
9.40
10.41
13.21
14.22
17.02
20.32
24.89
28.70

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.095
0.095
0.095
0.110
0.110

1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.41
2.41
2.41
2.79
2.79

0.17
0.19
0.21
0.27
0.31
0.36
0.42
0.53
0.58
0.69
0.77
0.87
1.00
1.22
1.37

4.32
4.83
5.33
6.86
7.87
9.14
10.67
13.46
14.73
17.53
19.56
22.10
25.40
30.99
34.80

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

SPEC 5125

June, 2013

GenFree II
®

LSZH XLPO, Low-Voltage Power, Unshielded
600 V, UL Type XHHW-2
Product Construction:
Conductor:

•	14 AWG thru 1000 kcmil stranded annealed bare
copper per ASTM B3
•	Compressed Class B stranding per ASTM B8

Insulation:

Applications (cont'd):

•	Low-Smoke, Zero-Halogen Flame-Retardant
Cross-linked Polyolefin (LSZH XLPO), black
•	Colors available upon request

Print:

•	GENERAL CABLE® (PLANT OF MFG) GENFREE® II
17 FREE™ LSZH TYPE XHHW-2 (SIZE) 600 V OIL
RES I SUN RES -40ºC ST1* FOR CT USE* (UL)
DAY/MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK
* “ST1” and “FOR CT USE” on 1/0 AWG and larger

•	Tinned copper conductor
•	Other stranding available
•	Colors available upon request

Applications:

•	For use in closed environments or populated spaces
such as auditoriums, arenas and health facilities
where more stringent customer specifications for
smoke and halogen-free materials are desired
•	Ideally suited for use in a broad range of commercial,
industrial and utility applications where reliability is a
major concern, where maximum performance will be
demanded and where space is limited

CATALOG
NUMBER

COND.
STRAND

Industry Compliances:
•	National Electrical Code (NEC)
•	 “FOR CT USE” on 1/0 AWG and larger in
accordance with NEC
•	UL 44 Type XHHW-2, UL File # E90494
•	Limited Smoke rating per UL 44 and UL 1685
•	ICEA T-33-655 smoke, halogen and acid gas
requirements
•	ICEA S-95-658/NEMA WC70
Flame Test Compliances:
•	For 1/0 AWG and larger: IEEE 383, IEEE 1202/CSA FT4
•	UL 1685
Other Compliances:
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP
•	OSHA Acceptable
•	RoHS Compliant

Features:

Options:

COND.
SIZE
(AWG/
kcmil)

Compliances:

•	For use in free air, raceways or direct burial in
accordance with NEC

NOMINAL COND.
DIAMETER
INCHES
mm

•	Rated at 90˚C wet or dry
•	Low-Smoke, Zero-Halogen insulation system
•	Smaller cable O.D.
• Low Friction for easy pulling on 8 AWG and larger
•	Excellent electrical, thermal and physical properties
•	Excellent moisture resistance, exceeding UL 44
requirements
•	Excellent resistance to crush, compression cuts  
and heat deformation
•	Excellent flame resistance
•	Resistant to most oils and chemicals
•	UV/sunlight-resistant
•	Rated ST-1 for Limited Smoke per UL 44 on sizes
1/0 AWG and larger
•	Stable electrical properties over a broad
temperature range
•	Excellent low temperature cold bend characteristics,
meets cold bend and cold impact test at -40˚C

MINIMUM AVG.
INSULATION
THICKNESS
INCHES
mm

NOMINAL CABLE
O.D.
INCHES
mm

Packaging:

• Material cut to length and shipped on nonreturnable wood reels

COPPER
WEIGHT

NET WEIGHT

LBS/
LBS/
1000 FT kg/km 1000 FT kg/km

AMPACITY (1)
60°C

75°C

90°C

15
20
30
40
55
70
95
110
125
145
165
195
215
260
320
350
400

15
20
30
50
65
85
115
130
150
175
200
230
255
310
380
420
475

15
20
30
55
75
95
130
145
170
195
225
260
290
350
430
475
535

14 AWG - 750 kcmil CONDUCTORS
5125.014*
5125.012*
5125.010*
5125.008*
5125.006*
5125.004*
5125.002*
5125.001*
5125.110*
5125.210*
5125.310*
5125.410*
5125.250*
5125.350*
5125.500*
5125.600*
5125.750*

14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250
350
500
600
750

7/.0240
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772
7/.0974
19/.0664
19/.0740
19/.0837
19/.0940
19/.1055
37/.0822
37/.0973
37/.1162
61/.0992
61/.1109

0.07
0.09
0.11
0.14
0.18
0.23
0.29
0.32
0.36
0.41
0.46
0.51
0.56
0.66
0.79
0.87
0.97

1.80
2.26
2.87
3.56
4.57
5.84
7.37
8.13
9.14
10.41
11.68
12.95
14.22
16.76
20.07
22.10
24.62

0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.080
0.080

0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.40
1.65
1.65
1.65
2.03
2.03

0.13
0.15
0.18
0.24
0.28
0.33
0.39
0.44
0.48
0.53
0.58
0.63
0.70
0.80
0.93
1.04
1.15

3.38
3.84
4.57
6.10
7.11
8.38
9.91
11.18
12.19
13.46
14.73
16.00
17.78
20.32
23.62
26.42
29.21

12
20
32
51
81
129
205
256
326
411
518
653
722
1081
1544
1853
2316

18
30
48
76
121
192
305
381
485
612
772
972
1074
1609
2298
2758
3447

17
26
38
65
99
152
233
293
364
453
565
706
837
1157
1634
1972
2448

25
39
57
97
147
226
347
437
572
674
842
1051
1246
1722
2432
2935
3643

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1)	Allowable ampacities shown are for general use as specified by the National Electric Code, 2011 Edition, section 310.15(B)(16). Adjustments and corrections may apply:
	 60°C – When terminated to equipment for circuits rated 100 amperes or less or marked for 14 through 1 AWG conductors.
	 75°C – When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG.
	 90°C – Wet or dry locations. For ampacity derating purposes.
	 Dwelling – For dwelling units, conductors shall be permitted as listed ampacities at 120/240-volt, 3-wire, single-phase services and feeders.

Going Green with General Cable
General Cable has accelerated its environmental commitment, addressing its green alternative approach by identifying greener opportunities
and promoting green cabling solutions wherever feasible. This includes promoting our existing green products, partnering with key customers
in their green endeavors, identifying and providing for green product gaps, and participating as a member of the United States Green Building
Council (USGBC) and collaborative ventures such as the Green Suppliers Network (GSN).

Phone: 888-593-3355
www.generalcable.com

SPEC 5150

October, 2012

XHHW-2 VW-1

XLPE, Control and Low-Voltage Power, 600 V
UL Type SIS/XHHW-2, VW-1 Rated, Single Conductor, Copper
Compliances:

Product Construction:
Conductor:

Applications:

•	For use in power and control circuits in
switchboards, control panels and raceways in
applications not exceeding 600 volts
•	Acceptable for use in OSHA regulated installations

•	18 AWG thru 1000 kcmil tinned, annealed
copper per ASTM B33
•	Class B stranding per ASTM B8

Features:

Insulation:

•	Flame-retardant Cross-linked Polyethylene (XLPE)

Print:

For 18 AWG and 16 AWG:
•	GENERAL CABLE ® (PLANT OF MFG) 1C XXAWG
COPPER XLPE SIS TYPE 600V 90C YEAR OF
MFG
For 14 AWG thru 4 AWG:
•	GENERAL CABLE ® (PLANT OF MFG) 1C XXAWG
COPPER XLPE TYPE SIS/XHHW-2 VW-1 (UL)
600V 90C YEAR OF MFG
For 2 AWG and larger:
•	GENERAL CABLE ® (PLANT OF MFG) 1C XXAWG
COPPER XLPE TYPE XHHW-2 VW-1 SUN RES
FOR CT USE (UL) YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

•	Rated at 90˚C wet or dry
•	UL Listed as SIS/XHHW-2¥ and XHHW-2¥¥ for
general power or control wiring in accordance
with the National Electrical Code, Section 310.15,
Tables 310.15(B)16 or 310.15(B)17
•	Sizes 1/0 and larger for CT use
•	Excellent flame resistance
•	Sunlight-resistant
•	Excellent physical, thermal and electrical
properties

Industry Compliances:
	 • UL Type SIS/XHHW-2¥—600 V
	 • UL File # E90494
	 • UL Type XHHW-2¥¥—600 V
	 • ICEA S-95-658/NEMA WC70
	 • 1/0 and larger are listed “Sun Res FOR CT
USE” in accordance with NEC
Flame Test Compliances:
	 • UL 44 VW-1
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

•	Material to be shipped on spools or nonreturnable wood reels
	UL Type SIS/XHHW-2 for sizes 14 AWG thru
4 AWG

¥

	UL Type XHHW-2 for sizes 2 AWG thru
1000 kcmil

¥¥

* Sizes smaller than 1/0 AWG do not include “FOR CT USE”

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

MINIMUM AVG.
NOMINAL COND.
INSULATION
DIAMETER
THICKNESS
INCHES mm INCHES mm

COPPER
WEIGHT
NET WEIGHT
NOMINAL CABLE
O.D.
LBS/
LBS/
INCHES mm 1000 FT kg/km 1000 FT kg/km

AMPACITY (1)
60°C

75°C

90°C

—
—
15
20
30
40
55
70
95
125
145
165
195
215
260
320
400
445

—
—
15
20
30
50
65
85
115
150
175
200
230
255
310
380
475
545

—
—
15
20
30
55
75
95
130
170
195
225
260
290
350
430
535
615

18 AWG - 1000 kcmil CONDUCTORS
381500
381510
381520
381530
381540
381550
381560
381570
06591.210200
06591.215100
06591.215200
06591.215300
06591.215400
06591.216000
06591.216200
06591.216500
06591.217000
06591.217500

18
16
14
12
10
8
6
4
2
1/0
2/0
3/0
4/0
250
350
500
750
1000

7/.0152
7/.0192
7/.0242
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772
7/.0974
19/.0745
19/.0837
19/.0940
19/.1055
37/.0822
37/.0973
37/.1162
61/.1109
61/.1280

0.05
0.06
0.07
0.09
0.11
0.14
0.18
0.23
0.29
0.36
0.41
0.46
0.51
0.56
0.66
0.79
0.97
1.13

1.27
1.47
1.80
2.29
2.87
3.56
4.57
5.84
7.37
9.14
10.41
11.68
12.95
14.22
16.76
20.07
24.64
28.70

0.030
0.030
0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.080
0.080

0.76
0.76
0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.65
1.65
1.65
2.03
2.03

0.11
0.12
0.13
0.15
0.18
0.24
0.28
0.32
0.38
0.48
0.52
0.57
0.63
0.70
0.80
0.93
1.14
1.30

2.74
3.05
3.38
3.86
4.45
6.05
6.99
8.18
9.68
12.14
13.28
14.55
15.98
17.75
20.37
23.65
29.03
33.02

5
8
13
20
32
51
81
129
205
326
411
518
653
772
1081
1544
2316
3086

8
12
19
30
48
76
121
192
305
485
612
771
972
1149
1609
2298
3447
4593

9
13
19
27
41
69
103
156
239
373
464
579
722
860
1185
1669
2520
3283

14
20
28
41
61
102
153
232
355
556
691
862
1075
1280
1764
2484
3750
4886

Dimensions and weights are nominal; subject to industry tolerances.
(1)	Allowable ampacities shown are for general use as specified by the National Electric Code, 2011 Edition, section 310.15(B)(16). Adjustments and corrections may apply:
	 60°C – When terminated to equipment for circuits rated 100 amperes or less or marked for 14 through 1 AWG conductors.
	 75°C – When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG.
	 90°C – Wet or dry locations. For ampacity derating purposes.
	 Dwelling – For dwelling units, conductors shall be permitted as listed ampacities at 120/240-volt, 3-wire, single-phase services and feeders.

Phone: 888-593-3355
www.generalcable.com

SPEC 5175
January, 2013

XHHW-2 CT

XLPE, Low-Voltage Power, 600 V
UL Type XHHW-2, CT Rated, Single Conductor, Copper
Product Construction:
Conductor:

•	14 AWG thru 750 kcmil annealed bare copper
per ASTM B3
•	Class B stranding per ASTM B8

Insulation:

•	Flame-retardant Cross-linked
Polyethylene (XLPE)

Features:

Print:

•	GENERAL CABLE ® (PLANT OF MFG) AWG/
KCMIL LOW FRICTION* TYPE XHHW-2 (UL) 600 V
SUN RES FOR CT USE** MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK
* Sizes 14 AWG - 10 AWG do not include “LOW FRICTION”
** Sizes smaller than 1/0 AWG do not include “SUN RES FOR
CT USE”

Options:

•	Tinned copper conductor
•	Full colored insulation

•	Low Friction for easy pulling on 8 AWG and larger
•	“FOR CT USE” on 1/0 AWG and larger
•	Sunlight-resistant for 1/0 AWG and larger, all
colors
•	Rated at 90˚C wet or dry
•	Smaller cable O.D.
•	Excellent electrical, thermal and physical
properties
•	Excellent resistance to moisture
•	Excellent resistance to crush, compression cuts
and heat deformation

Compliances:

Industry Compliances:
	 • National Electric Code (NEC)
	 • UL 44 Standard for Rubber Insulated Wire
and Cable
	 • ICEA S-95-658/NEMA WC70
	 • UL Listed as Type XHHW-2, UL File # E90494
	 • OSHA Acceptable
Flame Test Compliances:
	 • UL 1685, 1/0 AWG and larger

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

Applications:

•	General purpose building wire for use primarily in
conduit or other recognized raceways as specified
in the National Electrical Code
•	Industrial environments where superior insulation
toughness and chemical resistance are required
•	Maximum operating temperature not to exceed
90˚C in dry or wet locations
• In free air, raceways or cable trays in accordance
with NEC

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

NOMINAL COND.
DIAMETER
INCHES
mm

MINIMUM AVG.
INSULATION
THICKNESS
INCHES
mm

NOMINAL CABLE
O.D.
INCHES
mm

COPPER
WEIGHT

NET WEIGHT

LBS/
LBS/
1000 FT kg/km 1000 FT kg/km

AMPACITY (1)
60°C

75°C

90°C

15
20
30
40
55
70
95
110
125
145
165
195
215
260
320
350
400

15
20
30
50
65
85
115
130
150
175
200
230
255
310
380
420
475

15
20
30
55
75
95
130
145
170
195
225
260
290
350
430
475
535

14 AWG - 750 kcmil CONDUCTORS
391070
391080
391090
5175.008
5175.006
5175.004
5175.002
5175.001
5175.110
5175.210
5175.310
5175.410
5175.250
5175.350
5175.500
5175.600
5175.750

14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250
350
500
600
750

7/.0240
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772
7/.0974
19/.0664
19/.0740
19/.0837
19/.0940
19/.1055
37/.0822
37/.0973
37/.1162
37/.1109
61/.1280

0.07
0.09
0.11
0.14
0.18
0.23
0.29
0.32
0.36
0.41
0.46
0.51
0.56
0.66
0.79
0.87
0.98

1.80
2.26
2.87
3.56
4.57
5.84
7.37
8.13
9.14
10.41
11.68
12.95
14.22
16.76
20.07
22.10
24.89

0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.080
0.080

0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.40
1.65
1.65
1.65
2.03
2.03

0.13
0.15
0.18
0.24
0.28
0.33
0.39
0.44
0.48
0.53
0.58
0.63
0.70
0.80
0.93
1.04
1.15

3.38
3.84
4.57
6.10
7.11
8.38
9.91
11.18
12.19
13.46
14.73
16.00
17.78
20.32
23.62
26.42
29.21

12
20
32
51
81
129
205
256
326
411
518
653
722
1081
1544
1853
2316

18
30
48
76
121
192
305
381
485
612
772
972
1074
1609
2298
2758
3447

17
26
38
65
99
152
233
293
364
453
565
706
837
1157
1634
1972
2448

25
39
57
97
147
226
347
437
572
674
842
1051
1246
1722
2432
2935
3643

Dimensions and weights are nominal; subject to industry tolerances.
(1)	Allowable ampacities shown are for general use as specified by the National Electric Code, 2011 Edition, section 310.15(B)(16). Adjustments and corrections may apply:
	 60°C – When terminated to equipment for circuits rated 100 amperes or less or marked for 14 through 1 AWG conductors.
	 75°C – When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG.
	 90°C – Wet or dry locations. For ampacity derating purposes.
	 Dwelling – For dwelling units, conductors shall be permitted as listed ampacities at 120/240-volt, 3-wire, single-phase services and feeders.

Phone: 888-593-3355
www.generalcable.com

SPEC 5250

October, 2012

Unicon XLPE
®

XLPE, Low-Voltage Power
600 V, UL Type RHH/RHW-2/USE-2, Single Conductor, Copper
Features:

Product Construction:
Conductor:

•	Rated at 90˚C wet or dry
•	Smaller cable O.D.
•	Excellent electrical, thermal and physical
properties
•	Excellent resistance to moisture
•	Excellent resistance to crush, compression cuts
and heat deformation
•	Excellent flame resistance
•	Excellent low temperture cold bend characteristics
•	Meets cold bend test at -25˚C

Options:

•	14 AWG thru 1000 kcmil stranded annealed bare
copper compressed class B stranding per
ASTM B8

Insulation:

•	Flame-retardant Cross-linked Polyethylene (XLPE),
black

Print:

For 14 AWG – 4 AWG:
•	GENERAL CABLE® (PLANT OF MFG) UNICON®XLP TYPE USE-2 OR RHH OR RHW-2 VW-1 SIZE
(AWG OR KCMIL) 600 VOLTS SUN RES (UL) DAY/
MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE
MARK
For 2 AWG and larger:
•	GENERAL CABLE ® (PLANT OF MFG) UNICON®XLP TYPE USE-2 OR RHH OR RHW-2 VW-1
(SIZE) 600 VOLTS SUN RES FOR CT USE (UL)
DAY/MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

•	2 kV version
•	Tinned copper conductor
•	Class C stranding
•	Various colors available
•	Unicon® FREP ® — flame-retardant Ethylene
Propylene Rubber (EPR) insulation
•	Other constructions available upon request

Compliances:

Applications:

•	Ideally suited for use in a broad range of
commercial, industrial and utility applications
where reliability is a major concern, where
maximum performance will be demanded and
where space is limited
•	In free air, raceways or direct burial in accordance
with NEC

Industry Compliances:
	 • National Electrical Code (NEC)
	 • ICEA S-95-658/NEMA WC70
	 • “FOR CT USE” on 1/0 AWG and larger
in accordance with NEC
	 • UL 44 Type RHH/RHW-2, UL File # E90494
	 • UL 854 Type USE-2, UL File # E90499
Flame Test Compliances:
	 • UL 1581 VW-1
	 • For 1/0 AWG and larger: IEEE 383,
IEEE 1202/CSA FT4, ICEA T-29-520
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

* Sizes smaller than 1/0 AWG do not include “FOR CT USE”

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

MINIMUM AVG.
NOMINAL COND.
INSULATION
DIAMETER
THICKNESS
INCHES mm INCHES mm

COPPER
WEIGHT
NET WEIGHT
NOMINAL CABLE
O.D.
LBS/
LBS/
INCHES mm 1000 FT kg/km 1000 FT kg/km

AMPACITY (1)
60°C

75°C

90°C

15
20
30
40
55
70
95
125
145
195
215
260
320
400
445

15
20
30
50
65
85
115
150
175
230
255
310
380
475
545

15
20
30
55
75
95
130
170
195
260
290
350
430
535
615

14 AWG - 1000 kcmil CONDUCTORS
14
364830*
12
364840*
10
364850*
8
16602.210800
6
16602.210600
4
16602.210400
2
16602.210200
16602.215100 1/0
16602.215200 2/0
16602.215400 4/0
16602.216000 250
16602.216200 350
16602.216500 500
16602.217000 750
16602.217500* 1000

7/.0242
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772
7/.0974
19/.0740
19/.0837
19/.1055
37/.0822
37/.0973
37/.1162
61/.1109
61/.1280

0.07
0.09
0.12
0.15
0.18
0.23
0.29
0.37
0.41
0.52
0.56
0.67
0.80
0.98
1.13

1.78
2.29
3.05
3.81
4.57
5.84
7.37
9.40
10.41
13.21
14.22
17.02
20.32
24.89
28.70

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.095
0.095
0.095
0.110
0.110

1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.41
2.41
2.41
2.79
2.79

0.17
0.19
0.21
0.27
0.31
0.36
0.42
0.53
0.58
0.69
0.77
0.87
1.00
1.22
1.37

4.32
4.83
5.33
6.86
7.87
9.14
10.67
13.46
14.73
17.53
19.56
22.10
25.40
30.99
34.80

13
20
32
50
81
129
205
326
411
653
772
1081
1542
2316
3086

19
30
48
75
121
192
305
485
612
972
1149
1609
2295
3447
4593

24
33
48
78
114
169
254
403
501
760
906
1237
1730
2576
3405

36
49
71
116
170
252
378
600
746
1131
1349
1841
2575
3834
5068

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1)	Temperature, size and ampacity per National Electric Code, 2011 NEC sections 110.14(c)(1) (a) & (b).
	 60°C – When terminated to equipment for circuits rated 100 amperes or less or marked for 14 through 1 AWG conductors.
	 75°C – When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG.
	 90°C – Wet or dry locations. For ampacity derating purposes.
	 Dwelling – For dwelling units, conductors shall be permitted as listed ampacities at 120/240-volt, 3-wire, single-phase services and feeders.

Phone: 888-593-3355
www.generalcable.com

SPEC 5275

June, 2013

GenFree II
®

LSZH XLPO, Low-Voltage Power, Unshielded
600 V, UL Type RHH/RHW-2/USE-2
Product Construction:
Conductor:

•	14 AWG thru 1000 kcmil stranded annealed tinned
copper per ASTM B33
•	Compressed Class B stranding per ASTM B8

Insulation:

•	Low-Smoke, Zero-Halogen Cross-linked Polyolefin
(LSZH XLPO), black
•	Colors available upon request

Print:

•	GENERAL CABLE® (PLANT OF MFG) GENFREE® II
17 FREE™ LSZH TYPE USE-2 OR RHH OR RHW-2
(SIZE) 600 V OIL RES I SUN RES -40C ST1* FOR
CT USE* (UL) DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK
* “ST1” and “FOR CT USE” on 1/0 AWG and larger

Options:

•	2 kV version
•	Bare copper conductor
•	Other stranding available
•	Colors available upon request

Applications:

•	For use in closed environments or populated spaces
such as auditoriums, arenas and health facilities
where more stringent customer specifications for
smoke and halogen-free materials are desired
•	Ideally suited for use in a broad range of
commercial, industrial and utility applications
where reliability is a major concern, where
maximum performance will be demanded and
where space is limited

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

Applications (cont’d.):

•	For use in free air, raceways or direct burial in
accordance with NEC

Features:

•	Rated at 90˚C wet or dry
•	Low-Smoke, Zero-Halogen insulation system
•	Smaller cable O.D.
• Low Friction for easy pulling on 8 AWG and larger
•	Excellent electrical, thermal and physical
properties
•	Excellent moisture resistance, exceeding UL 44
requirements
•	Excellent resistance to crush, compression cuts
and heat deformation
•	Excellent flame resistance
•	Resistant to most oils and chemicals
•	UV/sunlight-resistant
•	Rated ST-1 for Limited Smoke per UL 44 on sizes
1/0 AWG and larger
•	Stable electrical properties over a broad
temperature range
•	Excellent low temperature characteristics, meets
cold bend and cold impact test at -40˚C

MINIMUM AVG.
NOMINAL COND.
INSULATION
DIAMETER
THICKNESS
INCHES mm INCHES mm

Compliances:

Industry Compliances:
•	National Electrical Code (NEC)
•	“FOR CT USE” on 1/0 AWG and larger in accordance
with NEC
•	UL 44 Type RHH/RHW-2, UL File # E90494
•	UL 854 Type USE-2, UL File # E90499
•	Limited Smoke rating per UL 44 and UL 1685
•	ICEA T-33-655 smoke, halogen and acid gas
requirements
•	ICEA S-95-658/NEMA WC70
Flame Test Compliances:
•	For 1/0 AWG and larger: IEEE 383, IEEE 1202/CSA FT4
•	UL 1685
Other Compliances:
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP
•	OSHA Acceptable
•	RoHS Compliant

Packaging:

• Material cut to length and shipped on non-returnable
wood reels

COPPER
WEIGHT
NET WEIGHT
NOMINAL CABLE
O.D.
LBS/
LBS/
INCHES mm 1000 FT kg/km 1000 FT kg/km

AMPACITY (1)
60°C

75°C

90°C

15
20
30
40
55
70
95
125
145
195
215
260
320
400
445

15
20
30
50
65
85
115
150
175
230
255
310
380
475
545

15
20
30
55
75
95
130
170
195
260
290
350
430
535
615

14 AWG - 1000 kcmil CONDUCTORS
17602.210014* 14
17602.210012* 12
17602.210010* 10
8
17602.210800*
6
17602.210600*
4
17602.210400*
2
17602.210200*
17602.215100* 1/0
17602.215200* 2/0
17602.215400* 4/0
17602.216000* 250
17602.216200* 350
17602.216500* 500
17602.217000* 750
17602.217500* 1000

7/.0242
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772
7/.0974
19/.0740
19/.0837
19/.1055
37/.0822
37/.0973
37/.1162
61/.1109
61/.1280

0.07
0.09
0.12
0.15
0.18
0.23
0.29
0.37
0.41
0.52
0.56
0.67
0.80
0.97
1.13

1.78
2.29
3.05
3.81
4.57
5.84
7.37
9.40
10.41
13.21
14.22
17.02
20.32
24.62
28.70

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.095
0.095
0.095
0.110
0.110

1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.41
2.41
2.41
2.79
2.79

0.17
0.19
0.21
0.27
0.31
0.36
0.42
0.53
0.58
0.69
0.77
0.87
1.00
1.22
1.37

4.32
4.83
5.33
6.86
7.87
9.14
10.67
13.46
14.73
17.53
19.56
22.10
25.40
30.99
34.80

13
20
32
50
81
129
205
326
411
653
772
1081
1542
2316
3086

19
30
48
75
121
192
305
485
612
972
1149
1609
2295
3447
4593

24
33
48
78
114
169
254
403
501
760
906
1237
1730
2576
3405

36
49
71
116
170
252
378
600
746
1131
1349
1841
2575
3834
5068

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1)	Allowable ampacities shown are for general use as specified by the National Electric Code, 2011 Edition, section 310.15(B)(16). Adjustments and corrections may apply:
	 60°C – When terminated to equipment for circuits rated 100 amperes or less or marked for 14 through 1 AWG conductors.
	 75°C – When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG.
	 90°C – Wet or dry locations. For ampacity derating purposes.
	 Dwelling – For dwelling units, conductors shall be permitted as listed ampacities at 120/240-volt, 3-wire, single-phase services and feeders.

Going Green with General Cable
General Cable has accelerated its environmental commitment, addressing its green alternative approach by identifying greener opportunities
and promoting green cabling solutions wherever feasible. This includes promoting our existing green products, partnering with key customers
in their green endeavors, identifying and providing for green product gaps, and participating as a member of the United States Green Building
Council (USGBC) and collaborative ventures such as the Green Suppliers Network (GSN).

Phone: 888-593-3355
www.generalcable.com

SPEC 5290

October, 2012

THHN/THWN-2

PVC, Low-Voltage Power
600 V, Type THHN/THWN-2, Single Conductor, Copper
Features (cont’d.):

Product Construction:
Conductor:

Print (cont’d.):

•	14 AWG thru 750 kcmil bare annealed stranded
copper per ASTM B3 and ASTM B8
•	14 AWG thru 10 AWG solid plain copper per ASTM
B3

Insulation:

•	Color-coded premium-grade flame-retardant,
heat- and moisture-resistant Polyvinyl Chloride
(PVC)

Jacket:

•	Tough Polyamide (Nylon)

Applications:

Print:

For 14 AWG solid thru 10 AWG solid:
•	GENERAL CABLE ® (PLANT OF MFG) (YEAR OF
MFG) THHN/THWN (SIZE) AWG (SIZE mm²)
GAS AND OIL RES II 600V VW-1 (UL) E66903
C(UL) T90 NYLON/TWN75 FT1 (-25°C)
For 14 AWG strand thru 10 AWG strand:
•	GENERAL CABLE ® (PLANT OF MFG) (YEAR OF
MFG) THHN/THWN (SIZE) AWG (SIZE mm²)
GAS AND OIL RES II 600V VW-1 OR AWM (UL)
E66903 C(UL) T90 NYLON/TWN75 FT1 (-25°C)
For 8 AWG thru 1 AWG:
•	GENERAL CABLE ® (PLANT OF MFG) (YEAR OF
MFG) LOW FRICTION THHN/THWN-2 (SIZE) AWG
(SIZE mm²) GAS AND OIL RES II 600V VW-1 OR
AWM (UL) E66903 C(UL) T90 NYLON/TWN75 FT1
(-25°C)

COLOR CODE CHART
COLOR
CODE

1
2
3
4
5
6

COLOR
Black
White
Red
Green
Yellow
Brown

For 1/0 and larger, black only:
•	GENERAL CABLE ® (PLANT OF MFG) (YEAR OF
MFG) LOW FRICTION THHN/THWN-2 (SIZE) AWG
(SIZE mm²) GAS AND OIL RES II OR SUN RES
FOR CT USE 600V OR AWM (UL) E66903 C(UL)
T90 NYLON/TWN75 FT1 (-25°C)
For 1/0 and larger, all colors:
•	GENERAL CABLE ® (PLANT OF MFG) (YEAR OF
MFG) LOW FRICTION THHN/THWN-2 (SIZE) AWG
(SIZE mm²) CU GAS AND OIL RES II FOR CT USE
600V OR AWM (UL) E66903 C(UL) T90 NYLON/
TWN75 FT1 (-25°C)
•	General purpose building wire for services,
feeders and branch circuits
•	Conduit and raceways
•	1/0 and larger for cable tray use

Features:

•	Low Friction Nylon jacket provides easy pulling for
8 AWG and larger
•	1/0 AWG and larger are rated for cable tray use
•	Rated Gasoline and Oil-Resistant II
•	Resistant to abrasion, acids, alkalines, ozone, and
water

•	For THHN applications, the conductor is
appropriate for use in dry locations not to exceed
90°C
•	For THWN-2 applications, the conductor is
appropriate for wet or dry locations not to exceed
90°C
•	For MTW applications, the conductor is
appropriate for use in dry locations at 90°C or not
to exceed 60°C in wet locations or where exposed
to oil or coolants (with ampacity limited to that
for 75°C conductor temperature) as outlined
in NFPA79 Electrical Standards for Industrial
Machinery
•	Sequential foot markings every 2 feet on 8 AWG
and larger for easy measuring
•	Sunlight-resistant for 1/0 and larger, for black only
•	Meets cold bend and cold impact tests at -25°C

Compliances:

Industry Compliances:
•	ASTM B3 and B8
•	UL Standard 83 – THHN/THWN-2
•	UL Standard 1063 for machine tool wire (MTW)
•	ICEA S-95-658/NEMA WC70
•	NEC® Article 310
•	RoHS Compliant
•	c(UL) – T90 Nylon
Flame Test Compliances:
•	UL 2556 VW-1 rated through 1 AWG
•	UL 2556 CT USE 1/0 and larger

Packaging:

•	Cut-to-length services available for 8 AWG
and larger

PACKAGING CODE CHART

COLOR
CODE

7
8
9
A
B

COLOR
Blue
Orange
Gray
Purple
Pink

PACKAGING
CODE

10
20
32
33
54
34
55
00
XX

PACKAGE
2x500'
4x500'
500' Reel
1000' Reel
2000' Reel
2500' Reel
5000' Reel
Cut to order
Master Reel

Phone: 888-593-3355
www.generalcable.com

SPEC 5290

October, 2012

THHN/THWN-2

PVC, Low-Voltage Power
600 V, Type THHN/THWN-2, Single Conductor, Copper
SIZE
CATALOG AWG OR
NUMBER kcmil mm²

INS. THKN.
NO. OF
WIRES

INCHES

mm

JACKET THKN.
INCHES

mm

NOMINAL
CABLE O.D.
INCHES

mm

COPPER WEIGHT
NET WEIGHT
LBS/
LBS/
1000 FT kg/km 1000 FT kg/km

AMPACITY (1)
60°C

75°C

90°C

PACKAGING
PUT-UP
CODE

TYPE THHN 90°C DRY LOCATIONS/THWN 75°C WET LOCATIONS
23014

14

2.08

1

0.015

0.38

0.004

0.10

0.101

2.57

12

18

15

22

15

15

15

20, 34

23012

12

3.31

1

0.015

0.38

0.004

0.10

0.120

3.05

20

29

23

34

20

20

20

20, 34

23010

10

5.26

1

0.020

0.51

0.004

0.10

0.149

3.78

31

47

37

55

20

20

30

10, 34

24014

14

2.08

19

0.015

0.38

0.004

0.10

0.109

2.77

13

19

16

25

15

15

15

20, 34

24012

12

3.31

19

0.015

0.38

0.004

0.10

0.127

3.23

20

30

23

36

20

20

20

20, 34

24010

10

5.26

19

0.020

0.51

0.004

0.10

0.160

4.07

32

48

38

57

30

30

30

10, 34

TYPE THHN/THWN-2 90°C WET OR DRY LOCATIONS
25008

8

8.37

19

0.030

0.76

0.005

0.13

0.212

5.39

51

76

62

94

40

50

55

32, 33, XX, 00

25006

6

13.3

19

0.030

0.76

0.005

0.13

0.248

6.30

81

121

94

141

55

65

75

32, 33, XX, 00

25004

4

21.2

19

0.040

1.02

0.006

0.15

0.317

8.06

129

192

153

228

70

85

95

32, 55, XX, 00

25003

3

26.7

19

0.040

1.02

0.006

0.15

0.344

8.74

163

242

189

281

85

100

115

32, 55, XX, 00

25002

2

33.6

19

0.040

1.02

0.006

0.15

0.375

9.53

205

305

233

348

95

115

130

55, XX, 00

25001

1

42.4

19

0.050

1.27

0.007

0.18

0.435

11.05

258

385

298

445

110

130

145

55, XX, 00

26110

1/0

53.5

19

0.050

1.27

0.007

0.18

0.474

12.04

326

485

372

554

125

150

170

55, XX, 00

26210

2/0

67.4

19

0.050

1.27

0.007

0.18

0.518

13.16

411

611

462

687

145

175

195

55, XX, 00

26310

3/0

85

19

0.050

1.27

0.007

0.18

0.568

14.43

518

771

572

851

165

200

225

55, XX, 00

26410

4/0

107

19

0.050

1.27

0.007

0.18

0.624

15.85

653

972

712

1059

195

230

260

55, XX, 00

27250

250

124

37

0.060

1.52

0.008

0.20

0.678

17.23

772

1149

849

1266

215

255

290

55, XX, 00

27300

300

152

37

0.060

1.52

0.008

0.20

0.730

18.54

926

1378

1010

1503

240

285

320

34, XX, 00

27350

350

177

37

0.060

1.52

0.008

0.20

0.777

19.74 1081

1609

1170

1741

260

320

350

34, XX, 00

27400

400

203

37

0.060

1.52

0.008

0.20

0.821

20.85 1235

1838

1330

1979

280

335

380

34, XX, 00

27500

500

253

37

0.060

1.52

0.008

0.20

0.902

22.91 1544

2298

1650

2455

320

380

430

34, XX, 00

27600

600

304

61

0.070

1.78

0.009

0.23

1.051

26.70 1853

2758

2019

3004

350

420

475

54, XX, 00

27750

750

380

61

0.070

1.78

0.009

0.23

1.156

29.36 2316

3447

2466

3670

400

475

535

54, XX, 00

Dimensions and weights are nominal; subject to industry tolerances.
(1)	Temperature, size and ampacity per National Electric Code, 2011 NEC sections 110.14(c)(1) (a) & (b).
	 60°C – When terminated to equipment for circuits rated 100 amperes or less or marked for 14 through 1 AWG conductors.
	 75°C – When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG.
	 90°C – Wet or dry locations. For ampacity derating purposes.
	 Dwelling – For dwelling units, conductors shall be permitted as listed ampacities at 120/240-volt, 3-wire, single-phase services and feeders.

Phone: 888-593-3355
www.generalcable.com

SPEC 5300
March, 2012

Super Vu-Tron

®

EPR/CPE, Diesel Locomotive Cable
90°C, 2000 V, DLO, UL Type RHH/RHW, 600 V, CSA Type R90, 1000 V
Product Construction:
Conductor:

•	14 AWG through 1111.1 kcmil stranded tinned
annealed copper per AAR 589

Insulation:

•	Premium-grade 90ºC EP

Jacket:

•	Chlorinated Polyethylene (CPE), black

COND.
SIZE
CATALOG (AWG/
NUMBER kcmil)

COND.
STRAND

NOM. INS.
THICKNESS
INCHES

mm

NOMINAL O.D.
INCHES

mm

CURRENT
AMPS
(1)

(2)

APPROX.
NET WEIGHT
LBS/MFT(S)

14 AWG - 1111.1 kcmil DLO - 2000 VOLT
81914*

14

19/0.0147

0.045

1.14

0.21

5.44

25

35

34

81912*

12

19/0.0185

0.047

1.19

0.24

6.10

30

40

45

81910*

10

27/24

0.045

1.14

0.26

6.60

40

55

60

81908*

8

37/24

0.060

1.52

0.34

8.64

55

80

95

81906*

6

61/24

0.060

1.52

0.40

10.16

75

105

145

81904*

4

105/24

0.060

1.52

0.46

11.68

95

140

205

81902*

2

154/24

0.060

1.52

0.52

13.21

130

190

295

81901*

1

224/24

0.080

2.03

0.65

16.51

150

220

440

81911*

1/0

280/24

0.080

2.03

0.69

17.53

170

260

515

81920*

2/0

329/24

0.080

2.03

0.73

18.54

195

300

580

81930*

3/0

456/24

0.080

2.03

0.81

20.57

225

350

770

81940*

4/0

551/24

0.080

2.03

0.87

22.10

260

405

930

81926* 262.6

650/24

0.095

2.41

1.00

25.40

296

467

1130

81931* 313.3

777/24

0.095

2.41

1.06

26.92

326

522

1295

81937* 373.7

925/24

0.095

2.41

1.10

27.94

362

591

1545

81944* 444.4

1110/24

0.095

2.41

1.23

31.24

400

652

1820

81953* 535.3

1332/24

0.120

3.05

1.34

34.04

445

728

2195

81964* 646.4

1609/24

0.120

3.05

1.45

36.83

493

815

2560

81977* 777.7

1924/24

0.120

3.05

1.50

38.10

546

904

3050

81929* 929.2

2299/24

0.120

3.05

1.67

42.42

602

1014

3625

81999* 1111.1 2745/24

0.140

3.56

1.84

46.74

635

1115

4354

Jacket Marking:

•	SIZES 14 THROUGH 1 AWG - CAROL SUPER
VU-TRON® (SIZE) (STRANDING) 90°C DLO 2000
VOLTS P-7K-123040 MSHA CSA R90 1000 V (UL)
RHH or RHW 600 VOLTS
•	SIZES 1/0 THROUGH 646.4 - CAROL SUPER
VU-TRON® (SIZE) 90°C DLO 2000 VOLTS P-7K123040 MSHA CSA R90 1000 V (-40°C) FT-1 (UL)
RHH or RHW 600 VOLTS SUNLIGHT RESISTANT
FOR CT USE
NOTE: 535.3 AND 646.4 kcmil printed (UL) RHH
OR RHW 2000 VOLTS
•	SIZES 777.7 THROUGH 1111.1 kcmil - CAROL
SUPER VU-TRON® C(UL) TYPE RHW-2 2 kV
VW-1 FOR CT USE TYPE DLO 2000 V 90°C
P-102 MSHA

Applications:

•	Diesel electric locomotives
•	Telecom power supply
•	Mining and earth-moving equipment
•	Shipyards
•	Motor leads
•	Where flexible power leads must be installed in
conduit or raceways

Features:

•	90ºC temperature rating
•	Excellent impact and abrasion resistance
•	Resists oils, acids, alkalies, heat, flame
•	Flexible tinned copper stranding
•	FT4 upon request
•	Sunlight-resistant

Industry Approvals:

•	UL Type RHH/RHW, UL File # E90494
•	Accepted for listing as flame-resistant
by MSHA
•	CSA R90
•	RoHS Compliant

Packaging:

•	Lengths cut to order

Dimensions and weights are nominal; subject to industry tolerances.
(1)	
Ampacities based on 90°C conductor and 30°C ambient temperature based on the National Electrical Code® for not more
than three current-carrying conductors in raceway, cable or earth.
(2)	
Ampacities based on single conductor in free air, 90°C conductor temperature and an ambient air temperature of 30°C, in
accordance with National Electrical Code® (NEC).
(S)	
Actual shipping weight may vary.
* Non-stock item

Phone: 888-593-3355
www.generalcable.com

SPEC 5310
May, 2012

Diesel Locomotive Cable 2000 Volts (EPR/XL-CPE)

UL RHH/RHW-2 2000 V and C(UL) RW90 1000 V
Flexible, Oil-, Sunlight- and Ozone-Resistant, Flame-Retardant, -40°C to 90°C
Product Construction:
Conductor:

•	14 AWG (2.08 mm) thru 1111.1 kcmil (562 mm)
Class I fully annealed flexible stranded tin coated
copper per AAR 589

Insulation:

•	Flame-retardant, lead-free cross-linked Ethylene
Propylene (EP) with separator tape over the
conductor to facilitate stripping

Jacket:

•	Black, flame-retardant, sunlight-, ozone- and
oil-resistant, lead-free Cross-linked Chlorinated
Polyethylene (XL-CPE)

Print:

•	GENERAL CABLE ® (MFG LOCATION) DIESEL
LOCOMOTIVE 2000 V P-07-KA120005-MSHA
C(UL)US TYPE RHH OR RHW-2 VW-1 (SIZE)
AWG/kcmil (MM2) EP FOR CT USE* SR -40ºC FT4
OR RW90 EP 1000 V ROHS MONTH/YEAR OF
MFG SEQUENTIAL FOOTAGE MARK
	 *Applicable for sizes 1/0 AWG and larger only

Options:

•	Fully annealed, flexible bare copper stranding per
AAR 589
•	Other jacket colors available upon request

Applications:

•	For use up to 2000 V as power cables in
wind turbine generator applications per UL
Subject 6140
•	Diesel electric locomotives

COND. SIZE
CATALOG
NUMBER

AWG/
kcmil

14
5310.01014
12
5310.01012
10
5310.01010
8
5310.01008
6
5310.01006
4
5310.01004
2
5310.01002
1
5310.01001
1/0
5310.01110
2/0
5310.01210
3/0
5310.01310
4/0
5310.01410
262.6
5310.01262
313.3
5310.01313
373.7
5310.01373
444.4
5310.01444
535.3
5310.01535
646.4
5310.01646
777.7
5310.01777
5310.01929* 929.9
5310.01111* 1111.1

Applications (cont’d.):

•	Mining and earth-moving equipment
•	General purpose use as flexible power leads
•	Flexible power leads in cable trays in sizes
1/0 AWG and larger
•	Accepted for listing as flame-resistant by MSHA

Features:

•	Rated 90°C wet or dry per UL 44/CSA C.22.2-38
•	Flexible tinned copper stranding
•	Excellent resistance to oils, gear lubricants, ozone,
sunlight, heat and flame
•	Designed to withstand continuous flexing

Minimum Bend Radius:

•	8X O.D. for fixed installations or mobile
applications

Torsion Requirements:

•	+/-180° twists per meter for 5,000 cycles at -40°C
with cable weight compensated to 18 meters

Compliances:

Industry Compliances:
• Type RHH/RHW-2 per UL 44, UL File # E90494

NOMINAL
COND. O.D.

NOM. INS.
THICKNESS

AC Withstand Voltage Testing
requirements per UL 44:
14 - 10 AWG

6000 V

8 - 2 AWG

7500 V

1 - 4/0 AWG

9000 V

262.6 kcmil - 444 kcmil

10000 V

535.3 kcmil - 929.9 kcmil

11000 V

1111.1 kcmil

13500 V

NOMINAL O.D.

APPROX.
NET WEIGHT

mm2

COND.
STRAND

INCHES

mm

INCHES

mm

INCHES

mm

INCHES

mm

LBS/1000 FT

kg/km

2.08
3.31
5.26
8.36
13.3
21.1
33.6
42.4
53.5
67.4
85
107
133
158
189
225
271
327
394
475
562

19/.0147
19/.0185
27/24
37/24
61/24
105/24
158/24
224/24
280/24
329/24
456/24
551/24
650/24
777/24
925/24
1110/24
1332/24
1609/24
1924/24
2318/24
2745/24

0.070
0.088
0.117
0.144
0.190
0.262
0.315
0.375
0.435
0.465
0.535
0.581
0.617
0.671
0.735
0.786
0.877
0.960
1.054
1.230
1.328

1.8
2.2
3.0
3.7
4.8
6.7
8.0
9.5
11.0
11.8
13.6
14.8
15.7
17.0
18.7
20.0
22.3
24.4
26.8
31.2
33.7

0.045
0.045
0.045
0.055
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.115

1.1
1.1
1.1
1.4
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.9

0.015
0.015
0.015
0.030
0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.045
0.065
0.065
0.065
0.065
0.065
0.065
0.065
0.065
0.095

0.4
0.4
0.4
0.8
0.8
0.8
0.8
1.1
1.1
1.1
1.1
1.1
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.4

0.20
0.22
0.25
0.33
0.38
0.46
0.51
0.64
0.70
0.73
0.80
0.84
0.94
1.00
1.06
1.11
1.20
1.29
1.38
1.56
1.77

5.1
5.6
6.4
8.3
9.7
11.7
13.0
16.3
17.8
18.5
20.3
21.3
23.9
25.3
26.9
28.2
30.5
32.8
35.1
39.6
44.9

30
39
56
87
131
202
285
417
494
587
718
845
1050
1195
1384
1634
1925
2307
2728
3570
4232

45
58
83
129
195
301
424
621
735
874
1069
1258
1563
1778
2060
2432
2865
3433
4060
5313
6298

* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

JACKET
THICKNESS

•	c(UL)US Type RW90 per CSA C.22.2-38,
UL File # E90494
•	National Electrical Code (NEC)
•	ICEA S-95-658/NEMA WC70
•	“For CT Use” on 1/0 AWG and larger in
accordance with NEC®
• Accepted for listing as flame resistant by MSHA
•	RoHS Compliant
Flame Test Compliances:
• UL 2556 VW-1
•	IEEE 1202/CSA FT4 for sizes 1/0 AWG and larger

SPEC 5350

September, 2013

GenFree LSZH

DISCONTINUED

®

XLPE, Low-Smoke, Zero-Halogen (LSZH), Low-Voltage Power, Unshielded
600 V, Type RHH/RHW-LS/USE, CSA AWM I A/B, Class B
Compliances:

Product Construction:
Conductor:

Applications (cont’d.):

•	CT rated for installation in Cable Tray – 1/0 AWG
and larger
•	For use in all closed environments or populated
spaces such as auditoriums, arenas and health
facilities where more stringent specifications for
smoke and toxicity emission levels are desired
•	Ideally suited for use in a broad range of
commercial and Industrial applications where
reliability is the major concern, where maximum
performance is demanded and where space
is limited

•	14 AWG thru 750 kcmil bare compressed copper
per ASTM B3. Class B stranding per ASTM B8

Composite Insulation/Jacket:

•	Flame-retardant, oil-resistant, limited smoke
Cross-linked Polyethylene (XLPE), black

Print:

•	GENERAL CABLE ® GENFREE® LSZH (PLANT
OF MFG) (UL) TYPE USE OR RHH OR RHW-ST1
(SIZE) 600 V OIL RES I SUN RES FOR CT USE*/
CSA AWM I A/B 105˚C 600 V FT4 MONTH/YEAR
OF MFG SEQUENTIAL FOOTAGE MARK

•	Available in blue, green, red and gray
•	Tinned copper conductors

Applications:

•	General purpose 600 V Power Cable Applications
•	RHH/RHW ratings for installation in conduit
or raceway
•	USE rating for direct burial applications

CATALOG
NUMBER

• Material cut to length and shipped on nonreturnable wood reels

•	UL Type RHH/RHW/USE Rated at 90˚C dry,
75˚C wet, UL File # E90494 and E90499
•C
 SA AWM I A/B Rated at 105˚C
•	UL AWM styles 3237 and 3578
•	Smooth surface for reduced coefficient of friction
for ease of installation
•	Excellent moisture resistance
•	Excellent resistance to salt water
•	Available in colors for ease of phase identification
•	Minimum acid gas emissions under combustion
•	Meets cold bend test at -40˚C
•	Meets UL Oil Res. I and II

Options:

COND.
STRAND
(CLASS B)

Packaging:

Features:

* Sizes smaller than 1/0 AWG do not include “FOR CT USE”

COND.
SIZE
(AWG/
kcmil)

• UL 44 Standard for Rubber Insulated Wire
• UL 758 Standard for Appliance Wiring Material
• UL 854 Standard for Service Entrance Cable
• UL 1685 Standard for Vertical Tray Fire
Propagation and Smoke Release Test for Electrical
and Optical Fiber Cables
• Telcordia GR347 Core
• ICEA S-95-658/NEMA WC70
• ICEA T-33-655
• IEEE 1202 (70,000 BTU/hr)
• IEEE 383 (70,000 BTU/hr)
• Sizes 1/0 AWG and larger are listed “FOR CT USE”
• CSA FT4
• CSA Standard C22.2 No. 0.3
• CSA Standard C22.2 No. 210.2
• EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
• OSHA Acceptable

NOMINAL COND.
DIAMETER
INCHES
mm

MINIMUM AVG.
INSULATION THICKNESS
INCHES
mm

NOMINAL CABLE
O.D.
INCHES
mm

COPPER
WEIGHT

NET WEIGHT

LBS/
1000 FT

kg/km

LBS/
1000 FT

kg/km

14 AWG - 750 kcmil CONDUCTORS, CLASS B
14311.011400
14311.011200
14311.011000
14311.010800
14311.010600
14311.010400
14311.010200
14311.010100
14311.015100
14311.015200
14311.015300
14311.015400
14311.016000
14311.016200
14311.016500
14311.017000

14
12
10
8
6
4

7/.0242
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772

0.07
0.09
0.12
0.15
0.18
0.23

1.78
2.29
3.05
3.81
4.57
5.84

0.045
0.045
0.045
0.060
0.060
0.060

1.14
1.14
1.14
1.52
1.52
1.52

0.17
0.19
0.22
0.28
0.31
0.36

4.32
4.83
5.59
7.11
7.87
9.14

13
20
32
50
81
129

19
30
48
75
121
192

18
25
38
58
116
171

27
37
57
86
173
254

2
1
1/0
2/0
3/0
4/0
250
350
500
750

7/.0974
19/.0644
19/.0745
19/.0837
19/.0940
19/.1055
37/.0822
37/.0973
37/.1162
61/.1109

0.28
0.32
0.36
0.41
0.46
0.51
0.56
0.66
0.79
0.97

7.11
8.13
9.14
10.41
11.68
12.95
14.22
16.76
20.07
24.64

0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.110

1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41
2.79

0.42
0.49
0.53
0.58
0.63
0.68
0.76
0.87
1.00
1.21

10.67
12.45
13.46
14.73
16.00
17.27
19.30
22.10
25.40
30.73

205
258
326
411
518
653
772
1081
1544
2316

305
385
485
612
771
972
1149
1609
2298
3447

257
331
406
495
612
757
905
1237
1728
2572

382
493
604
737
911
1126
1347
1841
2571
3827

Dimensions and weights are nominal; subject to industry tolerances.

Phone: 888-593-3355
www.generalcable.com

SPEC 5400

September, 2013

GenFree LSZH
®

DISCONTINUED

XLPE, Low-Smoke, Zero-Halogen (LSZH), Low-Voltage Power, Unshielded
600 V, Type RHH/RHW-LS/USE, CSA AWM I A/B, Class I1
Product Construction:
Conductor:

•	14 AWG thru 750 kcmil tinned coated copper
per ASTM B3. Class I stranding per ASTM B8

Composite Insulation/Jacket:

•	Flame-retardant, oil-resistant, limited smoke
Cross-linked Polyethylene (XLPE), black

Print:

•	GENERAL CABLE ® GENFREE® LSZH (PLANT
OF MFG) (UL) TYPE USE OR RHH OR RHW-ST1
(SIZE) 600 V OIL RES. I SUN RES FOR CT USE*/
CSA AWM I A/B 105˚C 600 V FT4 MONTH/YEAR
OF MFG SEQUENTIAL FOOTAGE MARK
* Sizes smaller than 1/0 AWG do not include “FOR CT USE”

Options:

•	Available in blue, green, red and gray
•	Tinned copper conductors

Applications:

•	General purpose 600 V Power Cable Applications
•	RHH/RHW ratings for installation in conduit
or raceway
•	USE rating for direct burial applications
•	CT rated for installation in Cable Tray – 1/0 AWG
and larger
•	For use in all closed environments or populated
spaces such as auditoriums, arenas and health
facilities where more stringent specifications for
smoke and toxicity emission levels are desired
•	Ideally suited for use in a broad range of
commercial and Industrial applications where
reliability is the major concern, where maximum
performance is demanded and where space
is limited

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND
(CLASS I)¹

Features:

•	UL Type RHH/RHW/USE Rated at 90˚C dry,
75˚C wet, UL File # E90494 and E90499
•C
 SA AWM I A/B Rated at 105˚C
•	UL AWM styles 3237 and 3578
•	Smooth surface for reduced coefficient of friction
for ease of installation
•	Excellent moisture resistance
•	Excellent resistance to salt water
•	Available in colors for ease of phase identification
•	Minimum acid gas emissions under combustion
•	Meets cold bend test at -40˚C
•	Meets UL Oil Res. I and II

Compliances (cont’d.):

•	Sizes 1/0 AWG and larger are listed “FOR CT USE”
•	CSA FT4
•	CSA Standard C22.2 No. 0.3
•	CSA Standard C22.2 No. 210.2
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable

Packaging:

•	Material cut to length and shipped on nonreturnable wood reels

Compliances:

• UL 44 Standard for Rubber Insulated Wire
• UL 758 Standard for Appliance Wiring Material
•	UL 854 Standard for Service Entrance Cable
•	UL 1685 Standard for Vertical Tray Fire
Propagation and Smoke Release Test for Electrical
and Optical Fiber Cables
•	Telcordia GR347 Core
•	ICEA S-95-658/NEMA WC70
•	ICEA T-33-655
•	IEEE 1202 (70,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)

NOMINAL COND.
DIAMETER
INCHES
mm

MINIMUM AVG.
INSULATION THICKNESS
INCHES
mm

NOMINAL CABLE
O.D.
INCHES
mm

COPPER
WEIGHT

NET WEIGHT

LBS/
1000 FT

kg/km

LBS/
1000 FT

kg/km

14
21
33
51
80
134
205
261
329
417
524
682
779
1095
1517
2408

20
31
48
76
119
199
305
389
489
621
780
1014
1159
1630
2258
3584

20
27
39
59
120
184
266
356
433
529
654
831
946
1301
1821
2723

29
40
58
87
179
274
396
530
644
787
973
1237
1408
1936
2710
4052

14 AWG - 750 kcmil CONDUCTORS, CLASS I
14315.011400*
14315.011200*
14315.011000*
14315.010800*
14315.010600*
14315.010400*
14315.010200*
14315.010100*
14315.015100*
14315.015200*
14315.015300*
14315.015400*
14315.016000*
14315.016200*
14315.016500*
14315.017000*

14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250
350
500
750

41
65
65
41
63/24
105/24
161/24
210/24
259/24
329/24
413/24
532/24
608/24
851/24
1221/24
1850/24

0.07
0.09
0.12
0.16
0.21
0.26
0.32
0.38
0.42
0.47
0.53
0.61
0.65
0.78
0.95
1.11

1.88
2.39
3.15
4.06
5.33
6.60
8.13
9.65
10.67
11.94
13.46
15.49
16.51
19.81
24.13
28.19

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.110

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
¹ Class I: sizes 8 AWG and larger.

Phone: 888-593-3355
www.generalcable.com

1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41
2.79

0.18
0.20
0.23
0.29
0.34
0.38
0.45
0.55
0.59
0.64
0.71
0.78
0.85
1.00
1.16
1.36

4.57
5.08
5.84
7.37
8.64
9.65
11.43
13.97
14.99
16.26
18.03
19.81
21.59
25.40
29.46
34.54

SPEC 5700

March, 2012

RHH/RHW-2

XLPE, Low-Voltage Power, Unshielded
2000 V, UL Type RHH/RHW-2, Single Conductor, Aluminum
Features:

• Rated at 90°C wet or dry
• UV resistant - black is marked SR
• Smaller cable O.D.
• Excellent electrical, thermal and physical
properties
• Excellent resistance to moisture
• Excellent reisistance to crush, compression cuts
and heat deformation

Product Construction:
Conductor:

• 8 AWG thru 1000 kcmil compacted aluminum
ACM (AA-8000 Series)

Insulation:

• Flame-retardant Cross-linked
Polyethylene (XLPE), black

Print:

• GENERAL CABLE® (PLANT OF MFG) AWG/KCMIL
TYPE RHH/RHW-2 (UL) 2000 V YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

CATALOG
NUMBER

CONDUCTOR
SIZE
(AWG/kcmil)

Compliances:

Applications:

COND.
STRAND

NOMINAL CONDUCTOR
NOMINAL AVERAGE
DIAMETER
INSULATION THICKNESS
INCHES

• National Electric Code (NEC)
• UL 44 Stranded for rubber-insulated wires and
cables
• ICEA S-95-685/NEMA WC70
• UL Listed as Type RHH/RHW-2, UL File # E90494
• OSHA Acceptable

• For use from the lower control box at the base
of the wind power tower and out to the step-up
transformer through conduit
• General purpose building wire for use in air and
approved raceways
• Industrial environments where superior insulation
toughness and chemical resistance is required
• Maximum operating temperature not to exceed
90°C in wet or dry locations

mm

INCHES

mm

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

NOMINAL
CABLE O.D.
INCHES

NOMINAL ALUMINUM
WEIGHT

mm

LBS/1000 FT

kg/km

NET
WEIGHT
LBS/1000 FT

kg/km

8 AWG - 1000 kcmil CONDUCTORS
522582M*
650981M*
589692M*
313406M*
149512M*
827197M*
977766M*
861898M*
763699M*
607078M*
506887M*
292686M*
526839M*
883753M*
614607M

8

7/W

0.134

3.4

0.070

1.78

0.285

7.20

15.49

23.05

38.15

56.78

6

7/W

0.169

4.1

0.070

1.78

0.320

8.10

24.60

36.61

51.08

76.01

4

7/W

0.213

5.4

0.070

1.78

0.360

9.10

40.20

59.82

71.50

106.40

2

2/W

0.268

6.8

0.070

1.78

0.420

10.70

62.40

92.86

100.10

148.96

1

18/W

0.301

7.6

0.090

2.29

0.495

12.60

77.81

115.79

133.76

199.05

1/0

18/W

0.339

8.6

0.090

2.29

0.530

13.50

100.12

148.99

160.82

239.32

2/0

18/W

0.379

9.6

0.090

2.29

0.580

14.70

123.90

184.38

191.50

284.97

3/0

18/W

0.426

10.8

0.090

2.29

0.615

15.60

156.22

232.47

228.68

340.30

4/0

18/W

0.476

12.1

0.090

2.29

0.665

16.90

201.40

299.70

281.10

418.31

250

35/W

0.524

13.3

0.105

2.70

0.745

18.90

233.50

347.47

336.15

500.23

350

35/W

0.619

15.7

0.105

2.70

0.840

21.30

330.90

492.41

448.90

668.00

500

35/W

0.740

18.8

0.105

2.70

0.960

24.40

467.10

695.09

604.77

899.96

600

58/W

0.820

20.8

0.105

2.70

1.040

26.40

559.50

832.59

710.14

1056.76

750

58/W

0.910

23.1

0.120

3.05

1.175

29.90

700.50

1042.41

901.20

1341.08

1000

58/W

1.060

26.9

0.120

3.05

1.325

33.70

939.00

1397.33

1168.00

1738.10

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

NOW
AVAILABLE IN
SUN-RESISTANT

Harnessing the Renewable Power of the Sun
Solar Photovoltaic Wire: Why Choose SunGen ?
®

DEFORMATION-RESISTANT

The SunGen® Difference
DIRECT BURIAL

FLEXIBLE

MOISTURE-RESISTANT

COLD IMPACT

OIL-RESISTANT

UV/SUNLIGHT-RESISTANT

MECHANICALLY RUGGED

As a company committed to environmental stewardship and renewable energy, General Cable has
specifically designed its UL 4703 SunGen® suite of photovoltaic (PV) products to effectively and
efficiently connect solar panels and concentrated solar power technologies while being able to
withstand the harsh operating environments of solar power applications.
	 •	
	 •	
	 •	
	 •	
	 •	
	 •	
	 •	
	 •	
		
	 •	
	 •	

Resistant to UV/sunlight, ozone and water absorption
Rated for direct burial
Stable electrical properties over a broad temperature range (-40°C to 120°C)
Excellent flexibility and performance in low-temperature environments
Highly resistant to deformation, even in prolonged exposure at high temperatures
Mechanically rugged construction resists cutting, tearing and abrasions
CSA RPVU90 listed
TÜV certified, halogen-free, fire-retardant and low corrosive gas emission provide
added degree of safety
Single and multi-conductor cable constructions
18 AWG – 1000 kcmil stranded copper and 8 AWG – 1000 kcmil aluminum conductors

Per NEC Article 690, single conductor cable listed and labeled as photovoltaic (PV) wire and
single conductor cable Type USE-2 shall be permitted in exposed outdoor locations in photovoltaic
source circuits for photovoltaic module interconnections within the photovoltaic array. When it
comes to the wire and cable for today’s solar energy projects with PV module interconnections
within the photovoltaic array, General Cable’s SunGen® UL Listed 4703 PV wire carries a quad
rating and offers far more superior sunlight resistance and low-temperature flexibility for maximum
performance and reliability for long-term outdoor exposure to the sun.

SunGen® — the obvious choice for solar photovoltaic applications. See for yourself.
Key Performance Differences Between UL Type PV and UL Type USE-2 Wire
LOW SMOKE EMISSIONS

PV Wire
Applications/Compliances
Voltage: 600, 1000 and 2000 Volts
Direct Buried: 600, 1000 and 2000 Volts
Conduit/Duct/Raceway
NEC Article 690 – PV Systems
UL 4703 PV Wire
UL 854 USE-2
Flame Test Requirements: FT1 & VW-1
Maximum Operating Temperature:
90ºC Wet or Dry
Cold Bend: -40ºC

Phone: 888-593-3355
Phone: 888-593-3355
www.generalcable.com
www.generalcable.com

Weatherometer Sunlight Resistance:
720 Hour

SunGen® PV Wire UL Type PV/RHH/RHW-2/USE-2

UL Type USE-2

SPEC 5790

May, 2012

SunGen Global XLPE/LSZH XLPO, Photovoltaic Wire, TÜV 2 pfg
®

1169/08.2007 PV1-F AC Uo /U
0.6/1 kV, UL 4703, PV Wire 2000 V

Compliances:

Industry Compliances:
	 •	 UL 4703 PV Wire
	 •	 TÜV 2 pfg 1169/08.2007 PV1-F for use in
	 	 photovoltaic systems
	 •	 RoHS Compliant
Flame Test Compliances:
	 •	 UL 2556 VW-1
	 •	 EN 60332-1-2 vertical flame

Product Construction:
Conductor:

Composite Insulation/Jacket
(Sheath):

•	Zero-Halogen Cross-linked Polyethylene
(ZH XLPE) with black Low-Smoke, Zero-Halogen
Cross-linked Polyolefin (LSZH XLPO)

Features:

Print

•	GENERAL CABLE® (PLANT OF MFG) SUNGEN®
GLOBAL XX MM² (XX AWG) TÜV PV1-F 600/1000
VAC (UL) PV WIRE 2000 V DIR BUR 90ºC WET
OR DRY VW-1 SUN RES -40ºC ROHS MONTH/
YEAR SEQ MARKING

COND.
SIZE
(mm2)

COND.
STRAND
COUNT

•	Material cut to length and shipped on nonreturnable wood reels

•	TÜV 2 pfg 1169/08.2007: Single conductor,
sunlight-resistant photovoltaic wire -40ºC to
+90ºC, max temperature of conductor 120ºC for
20,000 hours
•	Rated Voltage: AC UO /U 0,6/1 kV max voltage
1.8 kV DC (conductor – conductor, non-earthed
system, circuit not under load)
•	UL 4703: Photovoltaic wire rated 90ºC wet or dry,
2000 V for use in photovoltaic system

•	1,5 mm² (16 AWG) thru 6,0 mm² (10 AWG) fully
annealed flexible stranded tinned copper with
Class 5 stranding per EN 60228 (IEC 60228)

CATALOG
NUMBER

Packaging:

Applications:

	 •	 Rated 90°C wet and dry
	 •	 UV/sunlight-resistant
	 •	 Meets cold bend and cold impact tests
		at -40°C
	 •	 Direct burial

MINIMUM AVG.
INSULATION
THICKNESS
INCHES
mm

MINIMUM AVG.
JACKET (SHEATH)
THICKNESS
INCHES
mm

NOMINAL CABLE
DIAMETER
INCHES
mm

COPPER
WEIGHT
LBS/
1000 FT

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

1,5 mm2 (16 AWG) - 6,0 mm2 (10 AWG) CONDUCTORS
395400
395390
395380
395370

1.5

28

0.045

1.14

0.030

0.76

0.216

5.49

9

13

28

42

2.5
4.0
6.0

46
56
84

0.045
0.045
0.045

1.14
1.14
1.14

0.030
0.030
0.030

0.76
0.76
0.76

0.234
0.263
0.277

5.94
6.68
7.04

14
24
36

21
36
54

35
49
63

52
73
94

Dimensions and weights are nominal; subject to industry tolerances.

Phone: 888-593-3355
www.generalcable.com

SPEC 5800

May, 2012

SunGen

®

Dual-Layer EPR/XL-CPE, Photovoltaic Wire, 600 V, UL Type
PV/USE-2/RHH or RHW-2
Single Conductor, Copper

Product Construction:
Conductor:

•	14 AWG thru 2 AWG tinned coated compressed
copper. Class C stranding per ASTM B33 and B8
•	1 AWG thru 1000 kcmil tinned coated compressed
copper. Class B stranding per ASTM B33 and B8

NOW
AVAILABLE IN
SUN-RESISTANT

Insulation:

•	Lead-free Ethylene Propylene Rubber (EPR)
colored for contrast with black jacket

Jacket:

•	Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated
Polyethylene (XL-CPE)

Print:

•	GENERAL CABLE® (PLANT OF MFG) SUNGEN®
600 V PV WIRE DIR BUR OR RHH OR RHW-2 OR
USE-2 (SIZE) 90°C WET OR DRY SUN RES (UL)
-40°C VW-1 MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

Options:

•	Bare copper conductor
•	Other stranding options are available upon request
•	Now available in colors

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

Applications:

•	Single conductor, sunlight-resistant, direct
burial photovoltaic wire rated 90°C wet or dry,
600 V for interconnection wiring of grounded
and ungrounded photovoltaic power systems
as described in Section 690.31(A) and other
applicable parts of the National Electrical Code
(NEC), NFPA 70

Compliances:

Industry Compliances:
	 • UL 4703 Type PV, UL File # E323451
	 • National Electrical Code (NEC)
	 • ICEA S-95-658/NEMA WC70
	 • UL 44 Type RHH or RHW-2, UL File # E90494
or E54260
	 • UL 854 Type USE-2, UL File # E90499
or E86307
	 • Limited Smoke Rating per UL
	 • RoHS Compliant
Flame Test Compliances:
	 • UL 1581 VW-1
	 • For sizes 1/0 and larger: IEEE 383,
IEEE 1202/CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Features:

•	Rated 90°C wet and dry
•	Rated for direct burial
•	Deformation-resistant at high temperatures
•	Excellent moisture resistance, exceeds UL 44
•	Stable electrical properties over a broad
temperature range
•	Extra tough, mechanically rugged dual-layer
construction
•	Increased flexibility
•	Resistant to most oils and chemicals
•	UV/sunlight-resistant
•	Meets cold bend and cold impact tests at -40°C

NOMINAL COND. O.D.
INCHES
mm

MINIMUM AVG.
INSULATION
THICKNESS
INCHES
mm

MINIMUM AVG.
JACKET THICKNESS
INCHES
mm

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

NOMINAL CABLE
DIAMETER
INCHES
mm

COPPER
WEIGHT
LBS/
1000 FT

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

14 AWG - 1000 kcmil CONDUCTORS
12211.711400
12211.711200
12211.711100
12211.710800*
12211.710600*
12211.710400*
12211.710200*
12211.710100*
12211.715100*
12211.715200*
12211.715300*
12211.715400*
12211.716250*
12211.716300*
12211.716350*
12211.716400*
12211.716500*
12211.716600*
12211.716750*
12211.717000*

14

19/.0142

0.070

1.78

0.030

0.76

0.030

0.76

0.201

5.10

13

19

32

48

12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

19/.0185
19/.0234
19/.0295
19/.0372
19/.0469
19/.0526
19/.0664
19/.0740
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

0.088
0.112
0.143
0.184
0.234
0.296
0.323
0.370
0.410
0.460
0.520
0.558
0.611
0.661
0.706
0.789
0.866
0.968
1.117

2.23
2.84
3.63
4.67
5.94
7.52
8.20
9.40
10.41
11.68
13.21
14.17
15.52
16.79
17.93
20.04
22.00
24.59
28.37

0.030
0.030
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.065
0.065
0.080
0.080
0.080

0.76
0.76
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.40
1.65
1.65
1.65
1.65
1.65
2.03
2.03
2.03

0.030
0.030
0.030
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080

0.76
0.76
0.76
1.14
1.14
1.14
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03

0.219
0.242
0.310
0.376
0.420
0.487
0.539
0.587
0.632
0.678
0.738
0.862
0.915
0.965
1.010
1.093
1.200
1.302
1.451

5.56
6.15
7.87
9.55
10.67
12.37
13.69
14.91
16.05
17.22
18.74
21.89
23.24
24.51
25.65
27.76
30.48
33.07
36.86

20
32
50
81
129
205
258
326
411
518
653
772
926
1063
1235
1509
1883
2316
3088

30
48
74
121
192
305
384
485
611
771
972
1149
1378
1582
1838
2246
2802
3447
4595

42
59
89
141
202
292
408
478
590
734
865
995
1167
1321
1508
1810
2237
2707
3534

62
88
132
210
301
434
607
711
878
1092
1287
1481
1737
1966
2244
2694
3329
4028
5259

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please contact Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

SPEC 5800A

SunGen

October, 2012

®

Dual-Layer EPR/XL-CPE, Photovoltaic Wire, 600 V, UL Type
PV/USE-2/RHH or RHW-2
Single Conductor, Aluminum

Features (cont’d.):

NOW
AVAILABLE IN
SUN-RESISTANT

•	Extra tough, mechanically rugged dual-layer
construction
•	Increased flexibility
•	Resistant to most oils and chemicals
•	UV/sunlight-resistant
•	Meets cold bend and cold impact tests at -40°C

Compliances:
Product Construction:
Conductor:

•	8 AWG thru 1000 kcmil compact aluminum ACM
(8000 series)

Insulation:

•	Lead-free Ethylene Propylene Rubber (EPR)
colored for contrast with black jacket

Jacket:

•	Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated
Polyethylene (XL-CPE)

Print:

•	GENERAL CABLE® (PLANT OF MFG) SUNGEN®
600 V PV WIRE DIR BUR OR RHH OR RHW-2 OR
USE-2 (SIZE) AL ACM 90°C WET OR DRY SUN
RES (UL) -40°C VW-1 MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

CATALOG
NUMBER

Industry Compliances:
	 • UL 4703 Type PV, UL File # E323451
	 • National Electrical Code (NEC)
	 • ICEA S-95-658/NEMA WC70
	 • UL 44 Type RHH or RHW-2, UL File # E90494
or E54260
	 • UL 854 Type USE-2, UL File # E90499
or E86307
	 • Limited Smoke Rating per UL
	 • RoHS Compliant
Flame Test Compliances:
	 • UL 1581 VW-1
	 • For sizes 1/0 and larger: IEEE 383,
IEEE 1202/CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Options:

•	Other stranding options are available upon request
•	Now available in colors

Applications:

•	Single conductor, sunlight-resistant, direct
burial photovoltaic wire rated 90°C wet or dry,
600 V for interconnection wiring of grounded
and ungrounded photovoltaic power systems
as described in Section 690.31(A) and other
applicable parts of the National Electrical Code
(NEC), NFPA 70

Features:

•	Rated 90°C wet and dry
•	Rated for direct burial
•	Deformation-resistant at high temperatures
•	Excellent moisture resistance, exceeds UL 44
•	Stable electrical properties over a broad
temperature range

COND.
SIZE
NOMINAL COND. O.D.
(AWG/
COND.
kcmil) STRAND (1) INCHES
mm

MINIMUM AVG.
INSULATION
THICKNESS
INCHES
mm

MINIMUM AVG.
JACKET THICKNESS
INCHES
mm

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

NOMINAL CABLE
DIAMETER
INCHES
mm

ALUMINUM
WEIGHT

NET WEIGHT

LBS/
1000 FT

kg/km

LBS/
1000 FT

kg/km

16
25
39
63
79
99
125
158
199
262
282
329
376
471
565
706
914

23
37
58
93
117
148
186
235
296
390
420
490
560
701
841
1051
1360

40
74
97
131
179
209
244
289
343
468
504
565
625
745
894
1068
1328

59
110
144
194
267
311
364
430
510
697
749
841
931
1108
1331
1589
1977

8 AWG - 1000 kcmil CONDUCTORS
8
12211.710800A*
6
12211.710600A*
4
12211.710400A*
2
12211.710200A*
1
12211.710100A*
12211.715100A* 1/0
12211.715200A* 2/0
12211.715300A* 3/0
12211.715400A* 4/0
12211.716250A* 250
12211.716300A* 300
12211.716350A* 350
12211.716400A* 400
12211.716500A* 500
12211.716600A* 600
12211.716750A* 750
12211.717000A* 1000

7/.0486
7/.0612
7/.0772
7/.0974
19/.0664
19/.0745
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

0.134
0.169
0.213
0.268
0.299
0.336
0.376
0.423
0.475
0.520
0.570
0.616
0.659
0.736
0.813
0.908
1.060

3.40
4.29
5.41
6.81
7.59
8.53
9.55
10.74
12.07
13.21
14.48
15.65
16.74
18.69
20.65
23.06
26.92

0.030
0.045
0.045
0.045
0.055
0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.065
0.065
0.080
0.080
0.080

0.76
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.40
1.65
1.65
1.65
1.65
1.65
2.03
2.03
2.03

0.030
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080

0.76
1.14
1.14
1.14
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03

0.258
0.357
0.401
0.456
0.539
0.576
0.616
0.663
0.715
0.824
0.874
0.920
0.963
1.040
1.147
1.242
1.394

6.55
9.07
10.19
11.58
13.69
14.63
15.65
16.84
18.16
20.93
22.20
23.37
24.46
26.42
29.13
31.55
35.41

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please contact Customer Service for price and delivery.
(1) For compact stranded constructions, the number of wires may be reduced as follows:
19-Wire Constructions — 18 wires minimum
37-Wire Constructions — 35 wires minimum
61-Wire Constructions — 58 wires minimum

Phone: 888-593-3355
www.generalcable.com

SPEC 5810

May, 2012

SunGen

®

Dual-Layer EPR/XL-CPE, Photovoltaic Wire, 2000 V, UL Type PV/RHH
or RHW-2 or 600 V USE-2
Single Conductor, Copper

Product Construction:
Conductor:

•	14 AWG thru 2 AWG tinned coated compressed
copper. Class C stranding per ASTM B33 and B8
•	1 AWG thru 1000 kcmil tinned coated compressed
copper. Class B stranding per ASTM B33 and B8

NOW
AVAILABLE IN
SUN-RESISTANT

Insulation:

•	Lead-free Ethylene Propylene Rubber (EPR)
colored for contrast with black jacket

Jacket:

•	Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated
Polyethylene (XL-CPE)

Print:
•	GENERAL CABLE ® (PLANT OF MFG) SUNGEN®
2000 V PV WIRE DIR BUR OR RHH OR RHW-2
OR 600 V USE-2 (SIZE) 90°C WET OR DRY
SUN RES (UL) -40°C VW-1 c(UL) RWU90
1000 V MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

Options:

•	Bare copper conductor
•	Other stranding options are available upon request
•	Now available in colors

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

Applications:

•	Single conductor, sunlight-resistant, direct
burial photovoltaic wire rated 90°C wet or dry,
2000 V for interconnection wiring of grounded
and ungrounded photovoltaic power systems
as described in Section 690.31(A) and other
applicable parts of the National Electrical Code
(NEC), NFPA 70

Compliances:

Industry Compliances:
	 • UL 4703 Type PV, UL File # E323451
	 • National Electrical Code (NEC)
	 • ICEA S-95-658/NEMA WC70
	 • UL 44 Type RHH or RHW-2, UL File # E90494
or E54260
	 • UL 854 Type USE-2 for 600 V, UL File # E90499
or E86307
	 • Limited Smoke Rating per UL
	 • RoHS Compliant
Flame Test Compliances:
	 • UL 1581 VW-1
	 • For sizes 1/0 and larger: IEEE 383,
IEEE 1202/CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Features:

•	Rated 90°C wet and dry
•	Rated for direct burial
•	Deformation-resistant at high temperatures
•	Excellent moisture resistance, exceeds UL 44
•	Stable electrical properties over a broad
temperature range
•	Extra tough, mechanically rugged dual-layer
construction
•	Increased flexibility
•	Resistant to most oils and chemicals
•	UV/sunlight-resistant
•	Meets cold bend and cold impact tests at -40°C

NOMINAL COND. O.D.
INCHES
mm

MINIMUM AVG.
INSULATION
THICKNESS
INCHES
mm

MINIMUM AVG.
JACKET THICKNESS
INCHES
mm

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

NOMINAL CABLE
DIAMETER
INCHES
mm

COPPER
WEIGHT
LBS/
1000 FT

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

14 AWG - 1000 kcmil CONDUCTORS
12221.711400
12221.711200
12221.711100
12221.710800*
12221.710600*
12221.710400*
12221.710200*
12221.710100*
12221.715100*
12221.715200*
12221.715300*
12221.715400*
12221.716250*
12221.716300*
12221.716350*
12221.716400*
12221.716500*
12221.716600*
12221.716750*
12221.717000*

14

19/.0142

0.070

1.78

0.045

1.14

0.030

0.76

0.232

5.89

13

19

36

54

12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

19/.0185
19/.0234
19/.0295
19/.0372
19/.0469
19/.0526
19/.0664
19/.0740
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

0.088
0.112
0.143
0.184
0.234
0.296
0.323
0.370
0.410
0.460
0.520
0.558
0.611
0.661
0.706
0.789
0.866
0.968
1.117

2.23
2.84
3.63
4.67
5.94
7.52
8.20
9.40
10.41
11.68
13.21
14.17
15.52
16.79
17.93
20.04
22.00
24.59
28.37

0.045
0.045
0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.065
0.065
0.075
0.075
0.075
0.075
0.075
0.090
0.090
0.090

1.14
1.14
1.40
1.40
1.40
1.40
1.65
1.65
1.65
1.65
1.65
1.91
1.91
1.91
1.91
1.91
2.29
2.29
2.29

0.030
0.030
0.030
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080

0.76
0.76
0.76
1.14
1.14
1.14
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03

0.250
0.273
0.332
0.398
0.442
0.507
0.561
0.607
0.652
0.700
0.760
0.882
0.935
0.985
1.030
1.113
1.222
1.324
1.473

6.35
6.93
8.43
10.11
11.23
12.88
14.25
15.42
16.56
17.78
19.30
22.40
23.75
25.02
26.16
28.27
31.04
33.63
37.41

20
32
50
81
129
205
258
326
411
518
653
772
926
1063
1235
1509
1883
2316
3088

30
48
74
121
192
305
384
485
611
771
972
1149
1378
1582
1838
2246
2802
3447
4595

46
64
95
148
208
306
440
505
615
747
891
1012
1184
1339
1527
1831
2262
2734
3564

68
95
141
220
309
455
655
751
915
1111
1326
1506
1763
1993
2273
2725
3367
4069
5303

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please contact Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

SPEC 5810A

SunGen

October, 2012

®

Dual-Layer EPR/XL-CPE, Photovoltaic Wire, 2000 V, UL Type PV/RHH
or RHW-2 or 600 V USE-2
Single Conductor, Aluminum

Features (cont’d.):

NOW
AVAILABLE IN
SUN-RESISTANT

•	Extra tough, mechanically rugged dual-layer
construction
•	Increased flexibility
•	Resistant to most oils and chemicals
•	UV/sunlight-resistant
•	Meets cold bend and cold impact tests at -40°C

Compliances:
Product Construction:
Conductor:

•	8 AWG thru 1000 kcmil compact aluminum ACM
(8000 series)

Insulation:

•	Lead-free Ethylene Propylene Rubber (EPR)
colored for contrast with black jacket

Jacket:

•	Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated
Polyethylene (XL-CPE)

Print:
•	GENERAL CABLE ® (PLANT OF MFG) SUNGEN®
2000 V PV WIRE DIR BUR OR RHH OR RHW-2
OR 600 V USE-2 (SIZE) AL ACM 90°C WET OR
DRY SUN RES (UL) -40°C VW-1 c(UL) RWU90
1000 V MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

CATALOG
NUMBER

Industry Compliances:
	 • UL 4703 Type PV, UL File # E323451
	 • National Electrical Code (NEC)
	 • ICEA S-95-658/NEMA WC70
	 • UL 44 Type RHH or RHW-2, UL File # E90494
or E54260
	 • UL 854 Type USE-2 for 600 V, UL File # E90499
or E86307
	 • Limited Smoke Rating per UL
	 • RoHS Compliant
Flame Test Compliances:
	 • UL 1581 VW-1
	 • For sizes 1/0 and larger: IEEE 383,
IEEE 1202/CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Options:

•	Other stranding options are available upon request
•	Now available in colors

Applications:

•	Single conductor, sunlight-resistant, direct
burial photovoltaic wire rated 90°C wet or dry,
2000 V for interconnection wiring of grounded
and ungrounded photovoltaic power systems
as described in Section 690.31(A) and other
applicable parts of the National Electrical Code
(NEC), NFPA 70

Features:

•	Rated 90°C wet and dry
•	Rated for direct burial
•	Deformation-resistant at high temperatures
•	Excellent moisture resistance, exceeds UL 44
•	Stable electrical properties over a broad
temperature range

COND.
SIZE
NOMINAL COND. O.D.
(AWG/
COND.
kcmil) STRAND (1) INCHES
mm

MINIMUM AVG.
INSULATION
THICKNESS
INCHES
mm

MINIMUM AVG.
JACKET THICKNESS
INCHES
mm

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

NOMINAL CABLE
DIAMETER
INCHES
mm

ALUMINUM
WEIGHT
LBS/
1000 FT
16
25
39
63
79
99
125
158
199
262
282
329
376
471
565
706
914

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

23
37
58
93
117
148
186
235
296
390
420
490
560
701
841
1051
1360

53
81
105
139
190
220
256
302
356
484
520
582
644
764
918
1094
1357

79
121
156
207
282
328
381
449
530
720
774
867
958
1137
1366
1628
2019

8 AWG - 1000 kcmil CONDUCTORS
8
12221.710800A*
6
12221.710600A*
4
12221.710400A*
2
12221.710200A*
1
12221.710100A*
12221.715100A* 1/0
12221.715200A* 2/0
12221.715300A* 3/0
12221.715400A* 4/0
12221.716250A* 250
12221.716300A* 300
12221.716350A* 350
12221.716400A* 400
12221.716500A* 500
12221.716600A* 600
12221.716750A* 750
12221.717000A* 1000

7/.0486
7/.0612
7/.0772
7/.0974
19/.0664
19/.0745
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

0.134
0.169
0.213
0.268
0.299
0.336
0.376
0.423
0.475
0.520
0.570
0.616
0.659
0.736
0.813
0.908
1.060

3.40
4.29
5.41
6.81
7.59
8.53
9.55
10.74
12.07
13.21
14.48
15.65
16.74
18.69
20.65
23.06
26.92

0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.065
0.065
0.075
0.075
0.075
0.075
0.075
0.090
0.090
0.090

1.40
1.40
1.40
1.40
1.65
1.65
1.65
1.65
1.65
1.91
1.91
1.91
1.91
1.91
2.29
2.29
2.29

0.030
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080

0.76
1.14
1.14
1.14
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03

0.308
0.377
0.421
0.476
0.559
0.596
0.636
0.683
0.735
0.844
0.894
0.940
0.983
1.060
1.169
1.264
1.416

7.82
9.58
10.69
12.09
14.20
15.14
16.15
17.35
18.67
21.44
22.71
23.88
24.97
26.92
29.69
32.11
35.97

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please contact Customer Service for price and delivery.
(1) For compact stranded constructions, the number of wires may be reduced as follows:
19-Wire Constructions — 18 wires minimum
37-Wire Constructions — 35 wires minimum
61-Wire Constructions — 58 wires minimum

Phone: 888-593-3355
www.generalcable.com

SPEC 5840
May, 2012

SunGen

®

XLPE, Photovoltaic Wire, 600 V, UL Type PV/USE-2 or 2000 V RHH or
RHW-2 or CSA RPVU90, 1000 V
Single Conductor, Copper

Product Construction:
Conductor:

NOW
AVAILABLE IN
SUN-RESISTANT

• 18 AWG thru 2 AWG tinned coated compressed
copper. Class C stranding per ASTM B33 and B8
• 1 AWG thru 1000 kcmil tinned coated
compressed copper. Class B stranding per ASTM
B33 and B8

Insulation:

• Flame-retardant Cross-linked Polyethylene
(XLPE), black

Print:

•	18 AWG and 16 AWG: GENERAL CABLE® (PLANT
OF MFG) SUNGEN® 600 V PV WIRE DIR BUR
90°C WET OR DRY SUN RES (UL) -40°C VW-1
MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE
MARK
•	14 AWG thru 1000 kcmil: GENERAL CABLE®
(PLANT OF MFG) SUNGEN® 600 V PV WIRE DIR
BUR OR 2000 V RHH OR RHW-2 OR 600 V USE-2
(SIZE) 90°C WET OR DRY SUN RES (UL) -40°C
VW-1 (CSA) RPVU90 1000 V MONTH/YEAR OF
MFG SEQUENTIAL FOOTAGE MARK

Options:

•	Bare copper conductor
•	Other stranding options are available upon
request
•	Now available in colors

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

Applications:

•	Single conductor, sunlight-resistant, direct
burial photovoltaic wire rated 90°C wet or dry,
600 V for interconnection wiring of grounded
and ungrounded photovoltaic power systems
as described in Section 690.31(A) and other
applicable parts of the National Electrical Code
(NEC), NFPA 70

Features:

•	Rated 90°C wet and dry
•	Rated for direct burial
•	Deformation-resistant at high temperatures
•	Excellent moisture resistance, exceeds UL 44
•	Stable electrical properties over a broad
temperature range
•	Increased flexibility
•	Excellent resistance to crush and compression
cuts
•	Resistant to most oils and chemicals
•	UV/sunlight-resistant
•	Meets cold bend and cold impact tests at -40°C

NOMINAL COND. O.D.
INCHES
mm

MINIMUM AVG.
INSULATION THICKNESS
INCHES
mm

Compliances:

Industry Compliances:
	 • UL 4703 Type PV, UL File # E323451
	 • National Electrical Code (NEC)
	 • ICEA S-95-658/NEMA WC70
	 • UL 44 Type RHH or RHW-2, UL File # E90494
	 • UL 854 Type USE-2, UL File # E90499
	 • CSA C22.2 No. 271 RPVU90
Flame Test Compliances:
	 • UL 1581 VW-1
	 • For sizes 1/0 and larger: IEEE 383,
IEEE 1202/CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

NOMINAL CABLE
DIAMETER
INCHES
mm

COPPER
WEIGHT
LBS/
1000 FT
5
8
13
20
32
50
81
129
205
258
326
411
518
653
772
926
1063
1235
1509
1883
2316
3088

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

7
12
19
30
48
74
121
192
305
384
485
611
771
972
1149
1378
1582
1838
2246
2802
3447
4595

14
18
27
36
51
85
123
180
267
333
410
502
620
767
923
1090
1240
1423
1718
2136
2597
3411

21
27
40
54
76
126
183
268
397
495
610
747
922
1141
1374
1622
1845
2117
2557
3179
3865
5076

18 AWG - 1000 kcmil CONDUCTORS
12411.711800*
12411.711600*
12411.711400
12411.711200
12411.711100
12411.710800*
12411.710600*
12411.710400*
12411.710200*
12411.710100*
12411.715100*
12411.715200*
12411.715300*
12411.715400*
12411.716250*
12411.716300*
12411.716350*
12411.716400*
12411.716500*
12411.716600*
12411.716750*
12411.717000*

18
16
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

19/.0092
19/.0117
19/.0142
19/.0185
19/.0234
19/.0295
19/.0372
19/.0469
19/.0526
19/.0664
19/.0740
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

0.045
0.056
0.070
0.088
0.112
0.143
0.184
0.234
0.296
0.323
0.370
0.410
0.460
0.520
0.558
0.611
0.661
0.706
0.789
0.866
0.968
1.117

1.14
1.42
1.78
2.23
2.84
3.63
4.67
5.94
7.52
8.20
9.40
10.41
11.68
13.21
14.17
15.52
16.79
17.93
20.04
22.00
24.59
28.37

0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.095
0.095
0.110
0.110
0.110
0.110
0.110
0.125
0.125
0.125

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please contact Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.41
2.41
2.41
2.41
2.41
2.79
2.79
2.79
2.79
2.79
3.18
3.18
3.18

0.169
0.180
0.194
0.214
0.238
0.307
0.348
0.398
0.460
0.515
0.563
0.608
0.658
0.714
0.784
0.837
0.887
0.932
1.015
1.122
1.224
1.373

4.29
4.57
4.93
5.43
6.04
7.80
8.84
10.11
11.68
13.08
14.30
15.44
16.71
18.13
19.91
21.26
22.53
23.67
25.78
28.50
31.09
34.87

SPEC 5840A

SunGen

October, 2012

®

XLPE, Photovoltaic Wire, 600 V, UL Type PV/USE-2 or 2000 V RHH or
RHW-2 or CSA RPVU90, 1000 V
Single Conductor, Aluminum

Compliances:

NOW
AVAILABLE IN
SUN-RESISTANT

Applications:

Product Construction:
Conductor:

•	8 AWG thru 1000 kcmil compact aluminum ACM
(8000 series)

Insulation:

• Flame-retardant Cross-linked Polyethylene
(XLPE), black

Features:

Print:

•	GENERAL CABLE (PLANT OF MFG) SUNGEN
600 V PV WIRE DIR BUR OR 2000 V RHH
OR RHW-2 OR 600 V USE-2 (SIZE) AL ACM
90°C WET OR DRY SUN RES (UL) -40°C VW-1
CSA RPVU90 1000 V MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK
®

Options:

®

•	Other stranding options are available upon request
•	Now available in colors

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND (1)

• Single conductor, sunlight-resistant, direct
burial photovoltaic wire rated 90°C wet or dry,
600 V for interconnection wiring of grounded
and ungrounded photovoltaic power systems
as described in Section 690.31(A) and other
applicable parts of the National Electrical Code
(NEC), NFPA 70
•	Rated 90°C wet and dry
•	Rated for direct burial
•	Deformation-resistant at high temperatures
•	Excellent moisture resistance, exceeds UL 44
•	Stable electrical properties over a broad
temperature range
•	Increased flexibility
•	Excellent resistance to crush and compression
cuts
•	Resistant to most oils and chemicals
•	UV/sunlight-resistant
•	Meets cold bend and cold impact tests at -40°C

NOMINAL COND. O.D.
INCHES
mm

MINIMUM AVG.
INSULATION THICKNESS
INCHES
mm

Industry Compliances:
	 • UL 4703 Type PV, UL File # E323451
	 • National Electrical Code (NEC)
	 • ICEA S-95-658/NEMA WC70
	 • UL 44 Type RHH or RHW-2, UL File # E90494
	 • UL 854 Type USE-2, UL File # E90499
	 • CSA C22.2 No. 271 RPVU90
Flame Test Compliances:
	 • UL 1581 VW-1
	 • For sizes 1/0 and larger: IEEE 383,
IEEE 1202/CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

NOMINAL CABLE
DIAMETER
INCHES
mm

ALUMINUM
WEIGHT
LBS/
1000 FT

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

8 AWG - 1000 kcmil CONDUCTORS
12411.710800A*
12411.710600A*
12411.710400A*
12411.710200A*
12411.710100A*
12411.715100A*
12411.715200A*
12411.715300A*
12411.715400A*
12411.716250A*
12411.716300A*
12411.716350A*
12411.716400A*
12411.716500A*
12411.716600A*
12411.716750A*
12411.717000A*

8

7/.0486

0.134

3.40

0.080

2.03

0.298

7.57

16

23

49

73

6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

7/.0612
7/.0772
7/.0974
19/.0664
19/.0745
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

0.169
0.213
0.268
0.299
0.336
0.376
0.423
0.475
0.520
0.570
0.616
0.659
0.736
0.813
0.908
1.060

4.29
5.41
6.81
7.59
8.53
9.55
10.74
12.07
13.21
14.48
15.65
16.74
18.69
20.65
23.06
26.92

0.080
0.080
0.080
0.095
0.095
0.095
0.095
0.095
0.110
0.110
0.110
0.110
0.110
0.125
0.125
0.125

2.03
2.03
2.03
2.41
2.41
2.41
2.41
2.41
2.79
2.79
2.79
2.79
2.79
3.18
3.18
3.18

0.333
0.377
0.432
0.495
0.532
0.572
0.619
0.671
0.746
0.796
0.842
0.885
0.962
1.069
1.164
1.316

8.46
9.58
10.97
12.57
13.51
14.53
15.72
17.04
18.95
20.22
21.39
22.48
24.43
27.15
29.57
33.43

25
39
63
79
99
125
158
199
262
282
329
376
471
565
706
914

37
58
93
117
148
186
235
296
390
420
490
560
701
841
1051
1360

64
85
117
153
180
214
256
307
399
430
487
544
656
798
963
1210

95
127
174
227
268
318
380
456
594
640
725
810
977
1187
1433
1801

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please contact Customer Service for price and delivery.
(1) For compact stranded constructions, the number of wires may be reduced as follows:
19-Wire Constructions — 18 wires minimum
37-Wire Constructions — 35 wires minimum
61-Wire Constructions — 58 wires minimum

Phone: 888-593-3355
www.generalcable.com

SPEC 5845
May, 2012

SunGen IC XLPE, Photovoltaic Wire, 600 V, UL Type PV/USE-2 or 2000 V
®

RHH or RHW-2 or CSA RPVU90
1000 V, Single Conductor, Copper

Product Construction:

NOW
AVAILABLE IN
SUN-RESISTANT

Conductor:
• 18 AWG thru 1000 kcmil bare compressed
copper. Class B per ASTM B8

Insulation:
• Flame-retardant Cross-linked Polyethylene
(XLPE), black

Print:
•	18 AWG and 16 AWG: GENERAL CABLE®
(PLANT OF MFG) SUNGEN® 600 V PV WIRE DIR
BUR 90°C WET OR DRY SUN RES (UL) -40°C
VW-1 MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK
•	14 AWG thru 1000 kcmil: GENERAL CABLE®
(PLANT OF MFG) SUNGEN® 600 V PV WIRE
DIR BUR OR 2000 V RHH OR RHW-2 OR 600 V
USE-2 (SIZE) 90°C WET OR DRY SUN RES (UL)
-40°C VW-1 (CSA) RPVU90 1000 V MONTH/
YEAR OF MFG SEQUENTIAL FOOTAGE MARK

Options:
•	Tinned copper conductor
•	Other stranding options are available upon
request
•	Now available in colors

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

Applications:

• Single conductor, sunlight-resistant, direct
burial photovoltaic wire rated 90°C wet or dry,
600 V for interconnection wiring of grounded
and ungrounded photovoltaic power systems
as described in Section 690.31(A) and other
applicable parts of the National Electrical Code
(NEC), NFPA 70

Features:

•	Rated 90°C wet and dry
•	Rated for direct burial
•	Deformation-resistant at high temperatures
•	Excellent moisture resistance, exceeds UL 44
•	Stable electrical properties over a broad
temperature range
•	Excellent resistance to crush and compression
cuts
•	Resistant to most oils and chemicals
•	UV/sunlight-resistant
•	Meets cold bend and cold impact tests at -40°C

NOMINAL COND. O.D.
INCHES
mm

MINIMUM AVG.
INSULATION THICKNESS
INCHES
mm

Compliances:

Industry Compliances:
	 • UL 4703 Type PV, UL File # E323451
	 • National Electrical Code (NEC)
	 • ICEA S-95-658/NEMA WC70
	 • UL 44 Type RHH or RHW-2, UL File # E90494
	 • UL 854 Type USE-2, UL File # E90499
	 • CSA C22.2 No. 271 RPVU90
Flame Test Compliances:
	 • UL 1581 VW-1
	 • For sizes 1/0 and larger: IEEE 383,
IEEE 1202/CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

NOMINAL CABLE
DIAMETER
INCHES
mm

COPPER
WEIGHT
LBS/
1000 FT
5
8
13
20
32
50
81
129
205
258
326
411
518
653
772
926
1063
1235
1509
1883
2316
3088

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

7
12
19
30
48
74
121
192
305
384
485
611
771
972
1149
1378
1582
1838
2246
2802
3447
4595

14
18
27
36
51
88
126
183
269
333
410
502
620
767
923
1090
1240
1423
1718
2136
2597
3411

21
27
40
54
76
131
186
272
401
495
610
747
922
1141
1374
1622
1845
2117
2557
3179
3865
5076

18 AWG - 1000 kcmil CONDUCTORS
12431.711800*
12431.711600*
12431.711400*
12431.711200
12431.711100
12431.710800
12431.710600*
12431.710400*
12431.710200*
12431.710100*
12431.715100*
12431.715200*
12431.715300*
12431.715400*
12431.716250*
12431.716300*
12431.716350*
12431.716400*
12431.716500*
12431.716600*
12431.716750*
12431.717000*

18
16
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

7/.0152
7/.0192
7/.0240
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772
7/.0974
19/.0664
19/.0740
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

0.045
0.056
0.070
0.088
0.112
0.143
0.184
0.234
0.296
0.323
0.370
0.410
0.460
0.520
0.558
0.611
0.661
0.706
0.789
0.866
0.968
1.117

1.14
1.42
1.78
2.23
2.84
3.63
4.67
5.94
7.52
8.20
9.40
10.41
11.68
13.21
14.17
15.52
16.79
17.93
20.04
22.00
24.59
28.37

0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.095
0.095
0.110
0.110
0.110
0.110
0.110
0.125
0.125
0.125

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please contact Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

1.52
1.52
1.52
1.52
1.52
2.02
2.02
2.02
2.02
2.41
2.41
2.41
2.41
2.41
2.79
2.79
2.79
2.79
2.79
3.18
3.18
3.18

0.169
0.180
0.194
0.214
0.238
0.313
0.356
0.405
0.466
0.515
0.563
0.608
0.658
0.714
0.784
0.837
0.887
0.932
1.015
1.122
1.224
1.373

4.29
4.57
4.93
5.43
6.04
7.95
9.04
10.29
11.84
13.08
14.30
15.44
16.71
18.13
19.91
21.26
22.53
23.67
25.78
28.50
31.09
34.87

SPEC 5850

May, 2012

SunGen

®

XLPE, Photovoltaic Wire, 2000 V, UL Type PV/RHH or RHW-2 or 600 V
USE-2 or CSA RPVU90, 1000 V
Single Conductor, Copper

Features (cont’d.):

NOW
AVAILABLE IN
SUN-RESISTANT

Product Construction:
Conductor:

Print (cont’d.):

•	18 AWG thru 2 AWG tinned coated compressed
copper. Class C stranding per ASTM B33 and B8
•	1 AWG thru 1000 kcmil tinned coated
compressed copper. Class B stranding per ASTM
B33 and B8

Insulation:

•	Flame-retardant Cross-linked Polyethylene
(XLPE), black  

Print:

•	18 AWG and 16 AWG: GENERAL CABLE
(PLANT OF MFG) SUNGEN® 2000 V PV
WIRE DIR BUR 90°C WET OR DRY SUN RES
(UL) -40°C VW-1 MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK
•	14 AWG thru 1000 kcmil: GENERAL CABLE®
(PLANT OF MFG) SUNGEN® 2000 V PV WIRE
DIR BUR OR RHH OR RHW-2 OR 600 V USE-2
®

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

	 (SIZE) 90°C WET OR DRY SUN RES (UL) -40°C
VW-1 (CSA) RPVU90 1000 V MONTH/YEAR OF
MFG SEQUENTIAL FOOTAGE MARK

Options:

•	Bare copper conductor
•	Other stranding options are available upon
request
•	Now available in colors

Applications:

•	Single conductor, sunlight-resistant, direct
burial photovoltaic wire rated 90°C wet or dry,
2000 V for interconnection wiring of grounded
and ungrounded photovoltaic power systems
as described in Section 690.31(A) and other
applicable parts of the National Electrical Code
(NEC), NFPA 70

Compliances:

Industry Compliances:
	 • UL 4703 Type PV, UL File # E323451
	 • National Electrical Code (NEC)
	 • ICEA S-95-658/NEMA WC70
	 • UL 44 Type RHH or RHW-2, UL File # E90494
	 • UL 854 Type USE-2 for 600 V, UL File # E90499
	 • CSA C22.2 No. 271 RPVU90
Flame Test Compliances:
	 • UL 1581 VW-1
	 • For sizes 1/0 and larger: IEEE 383,
IEEE 1202/CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

Features:

•	Material cut to length and shipped on
non-returnable wood reels

•	Rated 90°C wet and dry
•	Rated for direct burial

NOMINAL COND. O.D.
INCHES
mm

•	Deformation-resistant at high temperatures
•	Excellent moisture resistance, exceeds UL 44
•	Stable electrical properties over a broad
temperature range
•	Increased flexibility
•	Excellent resistance to crush and compression
cuts
•	Resistant to most oils and chemicals
•	UV/sunlight-resistant
•	Meets cold bend and cold impact tests at -40°C

MINIMUM AVG.
INSULATION THICKNESS
INCHES
mm

NOMINAL CABLE
DIAMETER
INCHES
mm

COPPER
WEIGHT
LBS/
1000 FT
5
8
13
20
32
50
81
129
205
258
326
411
518
653
772
926
1063
1235
1509
1883
2316
3088

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

7
12
19
30
48
74
121
192
305
384
485
611
771
972
1149
1378
1582
1838
2246
2802
3447
4595

16
21
32
42
57
87
123
181
266
350
429
527
647
796
938
1106
1257
1441
1737
2157
2620
3437

24
31
48
62
85
129
183
269
396
521
638
784
963
1184
1396
1646
1870
2144
2585
3211
3900
5115

18 AWG - 1000 kcmil CONDUCTORS
12421.711800*
12421.711600*
12421.711400
12421.711200
12421.711100
12421.710800*
12421.710600*
12421.710400*
12421.710200*
12421.710100*
12421.715100*
12421.715200*
12421.715300*
12421.715400*
12421.716250*
12421.716300*
12421.716350*
12421.716400*
12421.716500*
12421.716600*
12421.716750*
12421.717000*

18
16
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

19/.0092
19/.0117
19/.0142
19/.0185
19/.0234
19/.0295
19/.0372
19/.0469
19/.0526
19/.0664
19/.0740
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

0.045
0.056
0.070
0.088
0.112
0.143
0.184
0.234
0.296
0.323
0.370
0.410
0.460
0.520
0.558
0.611
0.661
0.706
0.789
0.866
0.968
1.117

1.14
1.42
1.78
2.23
2.84
3.63
4.67
5.94
7.52
8.20
9.40
10.41
11.68
13.21
14.17
15.52
16.79
17.93
20.04
22.00
24.59
28.37

0.075
0.075
0.075
0.075
0.075
0.085
0.085
0.085
0.085
0.105
0.105
0.105
0.105
0.105
0.120
0.120
0.120
0.120
0.120
0.135
0.135
0.135

1.90
1.90
1.90
1.90
1.90
2.16
2.16
2.16
2.16
2.67
2.67
2.67
2.67
2.67
3.05
3.05
3.05
3.05
3.05
3.43
3.43
3.43

0.199
0.210
0.224
0.244
0.268
0.326
0.363
0.406
0.474
0.538
0.586
0.631
0.674
0.737
0.804
0.857
0.907
0.952
1.035
1.142
1.244
1.393

5.05
5.33
5.69
6.20
6.81
8.28
9.22
10.31
12.04
13.66
14.88
16.03
17.12
18.72
20.42
21.77
23.04
24.18
26.29
29.01
31.60
35.38

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please contact Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

SPEC 5850A

SunGen

October, 2012

®

XLPE, Photovoltaic Wire, 2000 V, UL Type PV/RHH or RHW-2 or 600 V
USE-2 or CSA RPVU90, 1000 V
Single Conductor, Aluminum

Product Construction:
Conductor:

NOW
AVAILABLE IN
SUN-RESISTANT

•	8 AWG thru 1000 kcmil compact aluminum ACM
(8000 series)

Insulation:

• Flame-retardant Cross-linked Polyethylene
(XLPE), black

Print:
•	GENERAL CABLE® (PLANT OF MFG) SUNGEN®
2000 V PV WIRE DIR BUR OR RHH OR RHW-2
OR 600 V USE-2 (SIZE) AL ACM 90°C WET OR
DRY SUN RES (UL) -40°C VW-1 CSA RPVU90
1000 V MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

Options:

•	Other stranding options are available upon request
•	Now available in colors

Applications:

• Single conductor, sunlight-resistant, direct
burial photovoltaic wire rated 90°C wet or dry,
2000 V for interconnection wiring of grounded
and ungrounded photovoltaic power systems
as described in Section 690.31(A) and other
applicable parts of the National Electrical Code
(NEC), NFPA 70

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND (1)

Features:

•	Rated 90°C wet and dry
•	Rated for direct burial
•	Deformation-resistant at high temperatures
•	Excellent moisture resistance, exceeds UL 44
•	Stable electrical properties over a broad
temperature range
•	Increased flexibility
•	Excellent resistance to crush and compression
cuts
•	Resistant to most oils and chemicals
•	UV/sunlight-resistant
•	Meets cold bend and cold impact tests at -40°C

Compliances:

Industry Compliances:
	 • UL 4703 Type PV, UL File # E323451
	 • National Electrical Code (NEC)
	 • ICEA S-95-658/NEMA WC70
	 • UL 44 Type RHH or RHW-2, UL File # E90494
	 • UL 854 Type USE-2, UL File # E90499
	 • CSA C22.2 No. 271 RPVU90
Flame Test Compliances:
	 • UL 1581 VW-1
	 • For sizes 1/0 and larger: IEEE 383,
IEEE 1202/CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

NOMINAL COND. O.D.
INCHES
mm

MINIMUM AVG.
INSULATION THICKNESS
INCHES
mm

NOMINAL CABLE
DIAMETER
INCHES
mm

ALUMINUM
WEIGHT
LBS/
1000 FT

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

8 AWG - 1000 kcmil CONDUCTORS
12421.710800A*
12421.710600A*
12421.710400A*
12421.710200A*
12421.710100A*
12421.715100A*
12421.715200A*
12421.715300A*
12421.715400A*
12421.716250A*
12421.716300A*
12421.716350A*
12421.716400A*
12421.716500A*
12421.716600A*
12421.716750A*
12421.717000A*

8

7/.0486

0.134

3.40

0.085

2.16

0.310

7.87

16

23

52

78

6

7/.0612

0.169

4.29

0.085

2.16

0.345

8.76

25

37

67

100

4

7/.0772

0.213

5.41

0.085

2.16

0.389

9.88

39

58

90

133

2

7/.0974

0.268

6.81

0.085

2.16

0.444

11.28

63

93

122

182

1

19/.0664

0.299

7.59

0.105

2.67

0.515

13.08

79

117

162

241

1/0

19/.0745

0.336

8.53

0.105

2.67

0.552

14.02

99

148

191

284

2/0

19/.0837

0.376

9.55

0.105

2.67

0.592

15.04

125

186

225

334

3/0

19/.0940

0.423

10.74

0.105

2.67

0.639

16.23

158

235

267

398

4/0

19/.1055

0.475

12.07

0.105

2.67

0.691

17.55

199

296

319

475

250

37/.0822

0.520

13.21

0.120

3.05

0.766

19.46

262

390

413

615

300

37/.0900

0.570

14.48

0.120

3.05

0.816

20.73

282

420

445

663

350

37/.0972

0.616

15.65

0.120

3.05

0.862

21.89

329

490

503

749

400

37/.1040

0.659

16.74

0.120

3.05

0.905

22.99

376

560

561

835

500

37/.1159

0.736

18.69

0.120

3.05

0.982

24.94

471

701

675

1004

600

61/.0992

0.813

20.65

0.135

3.43

1.089

27.66

565

841

818

1217

750

61/.1109

0.908

23.06

0.135

3.43

1.184

30.07

706

1051

985

1466

1000

61/.1280

1.060

26.92

0.135

3.43

1.336

33.93

914

1360

1235

1838

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please contact Customer Service for price and delivery.
(1) For compact stranded constructions, the number of wires may be reduced as follows:
19-Wire Constructions — 18 wires minimum
37-Wire Constructions — 35 wires minimum
61-Wire Constructions — 58 wires minimum

Phone: 888-593-3355
www.generalcable.com

SPEC 5855
May, 2012

SunGen IC XLPE, Photovoltaic Wire, 2000 V, UL Type PV/RHH or RHW-2 or
®

600 V USE-2 or CSA RPVU90
1000 V, Single Conductor, Copper

Features (cont’d.):

NOW
AVAILABLE IN
SUN-RESISTANT

•	Excellent resistance to crush and compression
cuts
•	Resistant to most oils and chemicals
•	UV/sunlight-resistant
•	Meets cold bend and cold impact tests at -40°C

Compliances:
Product Construction:
Conductor:

Options:

•	18 AWG thru 1000 kcmil bare compressed
copper. Class B per ASTM B8

Insulation:

•	Flame-retardant Cross-linked Polyethylene
(XLPE), black

Print:

•	18 AWG and 16 AWG: GENERAL CABLE®
(PLANT OF MFG) SUNGEN® 2000 V PV
WIRE DIR BUR 90°C WET OR DRY SUN RES
(UL) -40°C VW-1 MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK
•	14 AWG thru 1000 kcmil: GENERAL CABLE®
(PLANT OF MFG) SUNGEN® 2000 V PV WIRE
DIR BUR OR RHH OR RHW-2 OR 600 V USE-2
(SIZE) 90°C WET OR DRY SUN RES (UL) -40°C
VW-1 (CSA) RPVU90 1000 V MONTH/YEAR OF
MFG SEQUENTIAL FOOTAGE MARK

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

COND.
STRAND

•	Tinned copper conductor
•	Other stranding options are available upon
request
•	Now available in colors

Applications:

•	Single conductor, sunlight-resistant, direct
burial photovoltaic wire rated 90°C wet or dry,
2000 V for interconnection wiring of grounded
and ungrounded photovoltaic power systems
as described in Section 690.31(A) and other
applicable parts of the National Electrical Code
(NEC), NFPA 70

Features:

•	Rated 90°C wet and dry
•	Rated for direct burial
•	Deformation-resistant at high temperatures
•	Excellent moisture resistance, exceeds UL 44
•	Stable electrical properties over a broad
temperature range

NOMINAL COND. O.D.
INCHES
mm

MINIMUM AVG.
INSULATION THICKNESS
INCHES
mm

Industry Compliances:
	 • UL 4703 Type PV, UL File # E323451
	 • National Electrical Code (NEC)
	 • ICEA S-95-658/NEMA WC70
	 • UL 44 Type RHH or RHW-2, UL File # E90494
or E54260
	 • UL 854 Type USE-2 for 600 V, UL File # E90499
or E86307
	 • CSA C22.2 No. 271 RPVU90
Flame Test Compliances:
	 • UL 1581 VW-1
	 • For sizes 1/0 and larger: IEEE 383,
IEEE 1202/CSA FT4
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

NOMINAL CABLE
DIAMETER
INCHES
mm

COPPER
WEIGHT
LBS/
1000 FT
5
8
13
20
32
50
81
129
205
258
326
411
518
653
772
926
1063
1235
1509
1883
2316
3088

NET WEIGHT

kg/km

LBS/
1000 FT

kg/km

7
12
19
30
48
74
121
192
305
384
485
611
771
972
1149
1378
1582
1838
2246
2802
3447
4595

16
21
32
42
57
87
123
181
266
350
429
527
647
796
938
1106
1257
1441
1737
2157
2620
3437

24
31
48
62
85
129
183
269
396
521
638
784
963
1184
1396
1646
1870
2144
2585
3211
3900
5115

18 AWG - 1000 kcmil CONDUCTORS
12441.711800*
12441.711600*
12441.711400*
12441.711200
12441.711100
12441.710800
12441.710600*
12441.710400*
12441.710200*
12441.710100*
12441.715100*
12441.715200*
12441.715300*
12441.715400*
12441.716250*
12441.716300*
12441.716350*
12441.716400*
12441.716500*
12441.716600*
12441.716750*
12441.717000*

18
16
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

7/.0152
7/.0192
7/.0240
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772
7/.0974
19/.0664
19/.0740
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

0.045
0.056
0.070
0.088
0.112
0.143
0.184
0.234
0.296
0.323
0.370
0.410
0.460
0.520
0.558
0.611
0.661
0.706
0.789
0.866
0.968
1.117

1.14
1.42
1.78
2.23
2.84
3.63
4.67
5.94
7.52
8.20
9.40
10.41
11.68
13.21
14.17
15.52
16.79
17.93
20.04
22.00
24.59
28.37

0.075
0.075
0.075
0.075
0.075
0.085
0.085
0.085
0.085
0.105
0.105
0.105
0.105
0.105
0.120
0.120
0.120
0.120
0.120
0.135
0.135
0.135

1.90
1.90
1.90
1.90
1.90
2.16
2.16
2.16
2.16
2.67
2.67
2.67
2.67
2.67
3.05
3.05
3.05
3.05
3.05
3.43
3.43
3.43

0.199
0.210
0.224
0.244
0.268
0.326
0.363
0.406
0.474
0.538
0.586
0.631
0.674
0.737
0.804
0.857
0.907
0.952
1.035
1.142
1.244
1.393

5.05
5.33
5.69
6.20
6.81
8.28
9.22
10.31
12.04
13.66
14.88
16.03
17.12
18.72
20.42
21.77
23.04
24.18
26.29
29.01
31.60
35.38

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please contact Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

SPEC 5880

May, 2012

SunGen MI
®

XLPE/PVC, AC Micro-Inverter Cable
600 V, UL Type TC-ER¹

Product Construction:
Conductor:

•	14 AWG thru 10 AWG fully annealed stranded bare
copper per ASTM B3
•	Class C stranding per ASTM B8

Insulation:

•	Flame-retardant Cross-linked Polyethylene (XLPE)
•	Color code: See chart below

Features (cont’d.):

Jacket:

•	Lead-free, flame-retardant, sunlight-resistant
Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) SUNGEN®
MI XX/C XXAWG FR-XLP/PVC (UL) TYPE TC-ER
XHHW-2 CDRS DIR BUR SUN RES 90˚C WET
OR DRY 600 V DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

Options:

Compliances:

•	Overall shielded multi-conductors
•	Other constructions available upon request

Applications:

•	In free air, raceways and direct burial
•	In wet or dry locations
•	Approved for direct burial, Class I, Division 2
industrial hazardous locations per NEC
•	Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors

Features:

•	Rated at 90˚C wet or dry
•	Fillers as required to provide a round cable design
•	Ripcord applied under jacket to facilitate stripping

CATALOG
NUMBER

NO. COND.
OF
SIZE
COND. (AWG)

COND.
STRAND

•	Excellent physical and electrical properties
•	Increased flexibility
•	Excellent moisture resistance
•	Excellent resistance to compression and impact
•	Abrasion- and chemical-resistant
•	Sunlight- and weather-resistant
•	Meets cold bend test at -25˚C
•	Meets the crush and impact requirements of Type
MC cable for 3 or more conductors
Industry Compliances:
	 •	UL 44 Type XHHW-2
	 •	UL 1277 Type TC-ER for 3 or more conductors,
UL File # E57179
	 •	UL 1581
	 •	ICEA S-73-532
	 •	ICEA S-95-658/NEMA WC70
Flame Test Compliances:
	 •	UL 1581 VW-1
	 •	UL 1277
	 •	IEEE 383
	 •	IEEE 1202
	 •	ICEA T-29-520 (210,000 BTU/hr)
	 •	CSA FT4

NOMINAL COND.
O.D.
INCHES

mm

MINIMUM AVG.
INSULATION
THICKNESS
INCHES

mm

MINIMUM AVG.
JACKET THICKNESS
INCHES

mm

Compliances (cont’d.):

Other Compliances:
	 •	EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 •	OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

COLOR CODE CHART
NO. OF
CONDUCTORS

COLOR SEQUENCE

2
3
4
5

Black, White
Black, White, Green
Black, White, Red, Green
Black, White, Red, Orange, Green

Green insulated conductor indicates use for ground wire
only per NEC.

NOMINAL
CABLE O.D.
INCHES

COPPER WEIGHT

NET WEIGHT

mm

LBS/1000 FT

kg/km

LBS/1000 FT

kg/km

9.27
9.91
10.80
11.81

25
40
53
66

37
59
79
99

73
93
116
140

109
138
173
208

10.41
11.05
12.07
13.08

41
65
86
108

61
96
128
160

96
125
157
191

143
186
234
284

11.56
12.32
14.22
15.62

67
101
135
167

100
150
200
249

130
173
236
287

193
257
351
427

14 AWG MULTI-CONDUCTORS
395410*
395420
395430*
395440*

2
3
4
5

14
14
14
14

19/.0142
19/.0142
19/.0142
19/.0142

0.070
0.070
0.070
0.070

1.77
1.77
1.77
1.77

395450
395460
395470*
395480*

2
3
4
5

12
12
12
12

19/.0185
19/.0185
19/.0185
19/.0185

0.088
0.088
0.088
0.088

2.23
2.23
2.23
2.23

395490*
395500*
395510*
395520*

2
3
4
5

10
10
10
10

19/.0234
19/.0234
19/.0234
19/.0234

0.112
0.112
0.112
0.112

2.84
2.84
2.84
2.84

0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045

1.14
1.14
1.14
1.14

0.365
0.390
0.425
0.465

12 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045

1.14
1.14
1.14
1.14

0.410
0.435
0.475
0.515

10 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76

0.045
0.045
0.060
0.060

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please contact Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

Phone: 888-593-3355
www.generalcable.com

1.14
1.14
1.52
1.52

0.455
0.485
0.560
0.615

SPEC 5890

May, 2012

SunGen MI-LS
®

XLPO/LSZH, AC Micro-Inverter Cable
600 V, UL Type TC-LS-ER¹

Features (cont’d.):

• Meets the crush and impact requirements of Type
MC cable for 3 or more conductors

Compliances:

Product Construction:

Applications:

Conductor:
•	14 AWG thru 10 AWG fully annealed stranded bare
copper per ASTM B3
•	Class C stranding per ASTM B8

Insulation:
•	Lead-free, flame-retardant, low-smoke
Cross-linked Polyolefin (XLPO)
•	Color code: See chart below
•	Lead-free, flame-retardant, sunlight-resistant
Low-Smoke, Zero-Halogen Polyolefin (LSZH)  

Print:
•	GENERAL CABLE® (PLANT OF MFG) SUNGEN®
MI-LS XX/C XXAWG XLPO/LSZH (UL) TYPE
TC-LS-ER XHHW-2 CDRS 90°C WET OR DRY 600
V DIR BUR SUN RES ROHS DAY/MONTH/YEAR
OF MFG SEQUENTIAL FOOTAGE MARK

Options:
•	Overall shielded multi-conductor
•	Other constructions available upon request

CATALOG
NUMBER

COND.
STRAND

•	In free air, raceways, aerial or direct burial
•	In wet or dry locations
•	Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC
•	Permitted for Exposed Run (ER) use in
accordance with the NEC for 3 or more
conductors

Features:

Jacket:

NO. COND.
OF
SIZE
COND. (AWG)

Industry Compliances:
	 • UL 44 Type XHHW-2
	 • UL 1277 Type TC-LS-ER, UL File # E57179
	 • UL 1581
	 • RoHS Compliant
Flame Test Compliances:
	 • UL 1581
	 • UL 1277
	 • UL 1685
	 • IEEE 1202
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP
	 • OSHA Acceptable

•	Rated at 90˚C wet or dry
•	Fillers as required to provide a round cable design
•	Ripcord applied under jacket to facilitate stripping
•	Excellent physical and electrical properties
•	Increased flexibility
•	Excellent moisture resistance
•	Excellent resistance to compression and impact
•	Abrasion- and chemical-resistant
•	Low coefficient of friction for easy pulling
•	Sunlight- and weather-resistant
•	Meets cold bend test at -30˚C
•	Low-Smoke, Zero-Halogen jacket is
environmentally safe
•	Low-Smoke, Zero-Halogen jacket reduces the
amount of toxic and corrosive gases emitted
during combustion, providing a safer environment
for personnel and equipment during the hazards
of fire

NOMINAL COND.
O.D.
INCHES

mm

MINIMUM AVG.
INSULATION
THICKNESS
INCHES

mm

MINIMUM AVG.
JACKET THICKNESS
INCHES

mm

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels

COLOR CODE CHART
NO. OF
CONDUCTORS

COLOR SEQUENCE

2
3
4
5

Black, White
Black, White, Green
Black, White, Red, Green
Black, White, Red, Orange, Green

Green insulated conductor indicates use for ground wire
only per NEC.

NOMINAL
CABLE O.D.
INCHES

COPPER WEIGHT

NET WEIGHT

mm

LBS/1000 FT

kg/km

LBS/1000 FT

kg/km

9.40
9.91
10.80
11.81

25
40
53
66

37
59
79
99

71
92
115
139

106
137
171
207

10.41
11.05
12.07
13.08

41
65
86
108

61
96
128
160

94
124
157
191

140
185
234
284

11.56
12.32
14.22
15.62

67
101
135
167

100
150
200
249

128
172
234
284

190
256
348
423

14 AWG MULTI-CONDUCTORS
395530*
395540
395550*
395560*

2
3
4
5

14
14
14
14

19/.0142
19/.0142
19/.0142
19/.0142

0.070
0.070
0.070
0.070

1.77
1.77
1.77
1.77

395570
395580
395590*
395600*

2
3
4
5

12
12
12
12

19/.0185
19/.0185
19/.0185
19/.0185

0.088
0.088
0.088
0.088

2.23
2.23
2.23
2.23

395610*
395620*
395630*
395640*

2
3
4
5

10
10
10
10

19/.0234
19/.0234
19/.0234
19/.0234

0.112
0.112
0.112
0.112

2.84
2.84
2.84
2.84

0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045

1.14
1.14
1.14
1.14

0.370
0.390
0.425
0.465

12 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045

1.14
1.14
1.14
1.14

0.410
0.435
0.475
0.515

10 AWG MULTI-CONDUCTORS
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76

0.045
0.045
0.060
0.060

1.14
1.14
1.52
1.52

0.455
0.485
0.560
0.615

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please contact Customer Service for price and delivery.
¹ Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

Phone: 888-593-3355
www.generalcable.com

Date of Issue 06/13
Section 6		

Industrial Cables

2.4 kV — 35 kV Industrial Medium-Voltage Cables
SPECIFICATION NO.

PRODUCT DESCRIPTION

6050†

DuraSheath

6100†

REVISION DATE

EPR/XL-CPE, Medium-Voltage Power, Nonshielded
2400 V, UL Type MV-90

Aug. 2011

UniShield®

EPR/Copper Wire Shield/CPE, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils

Jun. 2013

6150

Uniblend®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils

Mar. 2012

6155†

Uniblend® LF

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils

Mar. 2012

6160†

®

Aluminum Uniblend® LF EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils

Mar. 2012

6175

Uniblend®

EPR/Copper Tape Shield/CPE, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils

Mar. 2012

6180†

GenFree®
Uniblend®

EPR/Copper Tape Shield/LSZH, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105/ST1, 133%/100% Ins. Levels, 115 Mils

Mar. 2012

6200

Copper Wire Shield

TRXLPE/Copper Wire Shield/PVC, Medium-Voltage Power
5 kV, UL Type MV-105, 100% Ins. Level, 90 Mils

Jan. 2011

6250

Uniblend®

EPR/Copper Tape Shield with Overall PVC Jacket
Medium-Voltage Power, Shielded, 5 kV and 8 kV, UL Type MV-105
133%/100% Ins. Levels, 115 Mils, Three Conductor

Mar. 2012

6255†

Uniblend® LF

EPR/Copper Tape Shield with Overall PVC Jacket
Medium-Voltage Power, Shielded, 5 kV and 8 kV, UL Type MV-105
133%/100% Ins. Levels, 115 Mils, Three Conductor

Mar. 2012

6275

Uniblend®

EPR/Copper Tape Shield with Overall CPE Jacket
Medium-Voltage Power, Shielded, 5 kV and 8 kV, UL Type MV-105
133%/100% Ins. Levels, 115 Mils, Three Conductor

Mar. 2012

6280

GenFree®
Uniblend®

EPR/Copper Tape Shield with Overall LSZH Jacket
Medium-Voltage Power, Shielded, 5 kV and 8 kV, UL Type MV-105
133%/100% Ins. Levels, 115 Mils, Three Conductor

Mar. 2012

†Indicates

these products are stocked by General Cable

Phone: 888-593-3355
www.generalcable.com

		
Industrial Cables		

Date of Issue 06/13
Section 6

2.4 kV — 35 kV Industrial Medium-Voltage Cables
SPECIFICATION NO.

PRODUCT DESCRIPTION

REVISION DATE

6300†

®

UniShield

EPR/Copper Wire Shield/CPE, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils

Jun. 2013

6350

Uniblend®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils

Mar. 2012

6355†

Uniblend® LF

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils

Apr. 2011

6360†

Aluminum Uniblend® LF

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils

Apr. 2011

6375

Uniblend®

EPR/Copper Tape Shield/CPE, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils

Apr. 2011

6380†

GenFree®
Uniblend®

EPR/Copper Tape Shield/LSZH, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105/ST1, 133% Ins. Level, 220 Mils

Mar. 2012

6400

Copper Wire Shield

TRXLPE/Copper Wire Shield/PVC, Medium-Voltage Power
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils

Jan. 2011

6450

Uniblend®

EPR/Copper Tape Shield with Overall PVC Jacket
Medium-Voltage Power, Shielded, 15 kV, UL Type MV-105
133% Ins. Level, 220 Mils, Three Conductor

Mar. 2012

6455†

Uniblend® LF

EPR/Copper Tape Shield with Overall PVC Jacket
Medium-Voltage Power, Shielded, 15 kV, UL Type MV-105
133% Ins. Level, 220 Mils, Three Conductor

Mar. 2012

6475

Uniblend®

EPR/Copper Tape Shield with Overall CPE Jacket
Medium-Voltage Power, Shielded, 15 kV, UL Type MV-105
133% Ins. Level, 220 Mils, Three Conductor

Mar. 2012

†Indicates

these products are stocked by General Cable

Phone: 888-593-3355
www.generalcable.com

Date of Issue 06/13
Section 6 		

Industrial Cables

2.4 kV — 35 kV Industrial Medium-Voltage Cables
SPECIFICATION NO.

PRODUCT DESCRIPTION

REVISION DATE

6480

GenFree
Uniblend®

EPR/Copper Tape Shield with Overall LSZH Jacket
Medium-Voltage Power, Shielded, 15 kV, UL Type MV-105
133% Ins. Level, 220 Mils, Three Conductor

Mar. 2012

6500

UniShield®

EPR/Copper Wire Shield/CPE, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils

Jun. 2013

6550

Uniblend®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils

Mar. 2012

6555†

Uniblend® LF

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils

Mar. 2012

Aluminum Uniblend® LF EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils

Mar. 2012

6560

®

6575

Uniblend®

EPR/Copper Tape Shield/CPE, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils

Mar. 2012

6580

GenFree®
Uniblend®

EPR/Copper Tape Shield/LSZH, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105/ST1, 133%/100% Ins. Levels, 345 Mils

Mar. 2012

6600

Uniblend®

EPR/Copper Tape Shield with Overall PVC Jacket
Medium-Voltage Power, Shielded, 25 kV and 35 kV, UL Type MV-105
133%/100% Ins. Levels, 345 Mils, Three Conductor

Mar. 2012

6605

Uniblend® LF

EPR/Copper Tape Shield with Overall PVC Jacket
Medium-Voltage Power, Shielded, 25 kV and 35 kV, UL Type MV-105
133%/100% Ins. Levels, 345 Mils, Three Conductor

Mar. 2012

6650

Uniblend®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
35 kV, UL Type MV-105, 133% Ins. Levels, 420 Mils

Apr. 2011

6655

Uniblend® LF

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
35 kV, UL Type MV-105, 133% Ins. Levels, 420 Mils

Apr. 2011

Aluminum Uniblend® LF EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
35 kV, UL Type MV-105, 133% Ins. Levels, 420 Mils

Apr. 2011

6660

†Indicates

these products are stocked by General Cable

Phone: 888-593-3355
www.generalcable.com

SPEC 6050

August, 2011

DuraSheath

®

EPR/XL-CPE, Medium-Voltage Power, Nonshielded
2400 V, UL Type MV-90
Features:

Product Construction
Conductor:

• Rated at 90˚C
• Excellent heat and moisture resistance
• Flexibility for easy handling
• High dielectric strength
• Low moisture absorption
• Electrical stability under stress
• Low dielectric loss
• Chemical- and sunlight-resistant
• Simplification of splicing and terminating by
elimination of need to handle cable shield
• Extra-tough, mechanically rugged composite
insulation and jacket construction
• Meets cold bend test at -35˚C

Options:

•	Multi-conductor constructions
•	Other constructions available upon request

• 8 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Applications:

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black jacket material

Jacket:

•	Lead-Free Cross-linked Chlorinated Polyethylene
(XL-CPE)

Print:

•	GENERAL CABLE® (MI) SIZE (AWG or KCMIL)
COMPACT CU DURASHEATH ® 2400 VOLTS
NONSHIELDED EP TYPE MV-90 WET OR DRY
FOR CT USE OIL RES I (UL) MONTH/YEAR OF
MFG SEQUENTIAL FOOTAGE MARK

• Proven record of reliable performance through
extensive use in these applications: pulp and
paper mills, petrochemical plants, sewage
treatment facilities, water treatment plants,
steel mills, textile mills, utility power generating
stations, scrubbers and other environmental
protection systems, railroad and mining facilities
• For use in industrial and utility applications where
ease of installation is a major concern because
of limited space and exposure to personnel is
minimal
• For use in wet or dry locations when installed in
accordance with NEC
•	For use in aerial, conduit, open tray and
underground duct installations

Compliances:

• National Electric Code (NEC)
• ICEA S-96-659/NEMA WC71
• UL 1072
• UL listed as Type MV-90 for use in accordance
with NEC, UL File # E90501
• Sizes 1/0 AWG and larger are listed and marked
“FOR CT USE” in accordance with NEC and also
meet IEEE 383 (70,000 BTU/hr)
• Listed “oil-resistant I”
• Meets EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
• OSHA acceptable

Packaging:

• Material cut to length and shipped on
non-returnable wood reels

* Sizes smaller than 1/0 AWG do not include
“FOR CT USE”

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

14901.410800*
14901.410600
14901.410400
14901.410200
14901.410100*
14901.415100
14901.415200
14901.415300*
14901.415400
14901.416000
14901.416200
14901.416500
14901.417000
14901.417500*

8
6
4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

NOMINAL
CONDUCTOR
DIAMETER
INCHES mm

NOMINAL EXTRUDED
STRAND SHIELD
DIAMETER
INCHES
mm

NOMINAL
INSULATION
THICKNESS
INCHES
mm

NOMINAL
INSULATION
DIAMETER
INCHES
mm

NOMINAL
CABLE
O.D.
INCHES
mm

COPPER
WEIGHT

NET WEIGHT

LBS/
1000 FT

kg/
km

LBS/
1000 FT

kg/
km

51
81
129
205
259
326
411
518
653
772
1080
1544
2316
3086

76
121
192
305
385
485
612
771
972
1149
1607
2298
3447
4593

196
241
308
408
476
562
666
823
983
1183
1545
2077
3040
3913

292
359
458
607
708
836
991
1225
1463
1761
2299
3091
4524
5823

2400 V, UL TYPE MV-90
0.14
0.17
0.22
0.27
0.31
0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

3.56
4.32
5.59
6.86
7.87
8.64
9.65
10.92
12.19
13.46
15.75
18.80
23.11
26.92

0.15
0.19
0.23
0.29
0.33
0.36
0.41
0.45
0.50
0.55
0.64
0.77
0.94
1.09

3.81
4.83
5.84
7.37
8.38
9.14
10.41
11.43
12.70
13.97
16.26
19.56
23.88
27.69

0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.140
0.140
0.140
0.155
0.155

3.18
3.18
3.18
3.18
3.18
3.18
3.18
3.18
3.18
3.56
3.56
3.56
3.94
3.94

0.41
0.44
0.49
0.55
0.58
0.62
0.66
0.71
0.76
0.84
0.93
1.06
1.26
1.42

10.41
11.18
12.45
13.97
14.73
15.75
16.76
18.03
19.30
21.34
23.62
26.92
32.00
36.07

0.58
0.62
0.66
0.72
0.76
0.79
0.84
0.92
0.97
1.08
1.17
1.30
1.54
1.70

14.73
15.75
16.76
18.29
19.30
20.07
21.34
23.37
24.64
27.43
29.72
33.02
39.12
43.18

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

SPEC 6100

June, 2013

UniShield

®

EPR/Copper Wire Shield/CPE, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils
Product Construction:
Conductor:

•	2 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with black conducting shield
layers

Applications (cont’d.):

•	For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Composite Insulation Shield
and Jacket:

•	Six corrugated copper drain wires embedded in
composite layers of semi-conducting thermoset
copolymer and semi-conducting black flameretardant Chlorinated Polyethylene (CPE)

•	Rated at 105˚C
•	Reduced conductor size and shield system
provides the smallest premium medium-voltage
shielded power cable with full insulation
•	Smaller outside dimensions reduce the size of
duct needed or increase the ampacity
per duct
•	All features contribute to faster and
easier installation
•	Superior cold bend and cold impact
performance
•	Stable and constant shield short
circuit performance
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low dielectric loss
•	Low moisture absorption
•	Electrical stability under stress
•	Chemical-resistant
•	Sunlight-resistant
•	Meets cold bend test at -55˚C

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) COMPACT CU
UNISHIELD ® (INSULATION THICKNESS) EPR
DRTP SEMI-CON CPE JKT TYPE MV105 (VOLTAGE) KV% INSULATION LEVEL
SUN RES FOR CT USE (UL) SEQUENTIAL
FOOTAGE MARK
* Sizes smaller than 1/0 AWG do not include
“FOR CT USE”.

Applications:

•	Installed in a broad range of commercial,
industrial and utility projects such as pulp
and paper mills, petrochemical plants, steel
mills, textile mills, water and sewage treatment
facilities, environmental protection systems,
railroads, mines and fossil fuel utility generating
stations
•	Suitable for use in wet or dry locations when
installed in accordance with NEC

CATALOG
NUMBER

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Features:

Print:

NOMINAL
COND. CONDUCTOR
SIZE DIAMETER
(AWG/
kcmil) INCHES

Compliances:

INSULATION DRAIN
NOMINAL CABLE
DIAMETER
WIRE
INCHES
DIAMETER
WEIGHT
SIZE
MIN. MAX. (AWG) INCHES
mm
LBS/1000 FT kg/km

Packaging:

•	Material cut to length and shipped on nonreturnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and triplexing
	 NOTE: Due to the semi-conducting properties of the

cable jacket, multi-point grounding is recommended for
all UniShield® installations.

AMPACITY

COPPER WEIGHT
LBS/1000 FT kg/km

CONDUIT
CONDUIT UNDERGROUND SIZING (3)
IN AIR (1)
DUCT (2)
(INCHES)

5 kV AND 8 kV, UL TYPE MV-105, 133%/100% INS. LEVELS, 115 MILS
19101.650200
19101.655100
19101.665200
19101.665300*
19101.665400
19101.676000
19101.676200
19101.686500
19101.687000
19101.667500*

2
1/0
2/0
3/0
4/0
250
350
500
750
1000

0.27
0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

0.510
0.580
0.620
0.665
0.720
0.770
0.870
0.990
1.170
1.320

0.590
0.655
0.695
0.745
0.795
0.850
0.945
1.065
1.250
1.400

20
20
19
19
19
18
18
17
17
16

0.71
0.78
0.83
0.88
0.93
1.01
1.11
1.24
1.44
1.61

18.03
19.81
21.08
22.35
23.62
25.65
28.19
31.50
36.57
40.89

404
555
666
791
951
1112
1463
2003
2875
3746

601
825
990
1177
1415
1655
2176
2980
4278
5574

225
346
436
562
678
804
1113
1585
2357
3138

335
515
649
808
1010
1196
1656
2358
3507
4669

165
215
255
290
330
365
440
535
655
755

165
215
245
275
315
345
415
500
610
690

2.5
2.5
3
3
3
3.5
3.5
4
5
5

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all UniShield® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6150

March, 2012

Uniblend

®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils
Features:

Product Construction:
Conductor:

Print:

•	6 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC)

CATALOG
NUMBER

NOMINAL
COND. CONDUCTOR
SIZE DIAMETER
(AWG/
kcmil) INCHES

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) COMPACT CU
UNIBLEND ® PVC JKT (INSULATION THICKNESS)
EPR TYPE MV-105 (VOLTAGE) KV% INSULATION
LEVEL SUN RES FOR CT USE (UL) SEQUENTIAL
FOOTAGE MARK
* Sizes smaller than 1/0 AWG do not include
“FOR CT USE”.

Options:

• Other jacket options available upon request
• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610

Applications:

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
•	For use in wet or dry locations when installed in
accordance with NEC
•	For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

INSULATION
NOMINAL
DIAMETER
JACKET
INCHES
THICKNESS
MIN. MAX. INCHES mm

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL CABLE
AMPACITY
CONDUIT
COPPER WEIGHT
DIAMETER
WEIGHT
CONDUIT UNDERGROUND SIZING (3)
INCHES
mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1)
DUCT (2)
(INCHES)

5 kV AND 8 kV, UL TYPE MV-105, 133%/100% INS. LEVELS, 115 MILS
17001.120600*
17001.120400*
17001.120200*
17001.120100*
17001.125100*
17001.125200*
17001.125300*
17001.135400*
17001.136000*
17001.136200*
17001.136500*
17001.137000*
17001.637500*

6
4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

0.17
0.22
0.27
0.31
0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

0.415
0.455
0.510
0.545
0.580
0.620
0.665
0.720
0.770
0.870
0.990
1.170
1.320

0.490
0.535
0.590
0.620
0.655
0.695
0.745
0.795
0.850
0.945
1.065
1.250
1.400

0.060
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080

1.52
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03

0.65
0.70
0.76
0.79
0.82
0.86
0.94
1.00
1.05
1.14
1.27
1.45
1.60

16.51
17.15
19.05
20.07
21.08
22.10
24.38
25.65
27.18
29.72
33.53
38.35
42.42

295
365
471
539
623
728
886
1053
1199
1559
2088
2962
3815

439
543
701
802
927
1083
1318
1567
1784
2320
3107
4407
5677

126
178
259
315
386
474
585
725
849
1165
1639
2427
3210

188
265
385
468
575
706
871
1080
1263
1735
2439
3611
4777

93
120
165
190
215
255
290
330
365
440
535
655
755

97
125
165
185
215
245
275
315
345
415
500
610
690

2
2.5
2.5
2.5
3
3
3
3
3.5
3.5
4
5
5

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
	
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
		
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6155

March, 2012

Uniblend LF
®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils
Product Construction:
Conductor:

•	6 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

Applications:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Low-friction, lead-free, flame-retardant, moistureand sunlight-resistant Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) COMPACT CU
UNIBLEND ® LF PVC JKT (INSULATION
	 THICKNESS) EPR TYPE MV-105 (VOLTAGE) KV%
INSULATION LEVEL SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK
* Sizes smaller than 1/0 AWG do not include
“FOR CT USE”.

Options:

• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610

CATALOG
NUMBER

NOMINAL
COND. CONDUCTOR
SIZE DIAMETER
(AWG/
kcmil) INCHES

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
•	For use in wet or dry locations when installed in
accordance with NEC
•	For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system
with a ground conductor that is in close
proximity, and conforms with NEC 250.4(A)(5)

Features:

•	Rated at 105˚C
•	Lower coefficient of friction for ease of
installation
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

INSULATION
NOMINAL
DIAMETER
JACKET
INCHES
THICKNESS
MIN. MAX. INCHES mm

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL CABLE
AMPACITY
CONDUIT
COPPER WEIGHT
DIAMETER
WEIGHT
CONDUIT UNDERGROUND SIZING (3)
INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1)
DUCT (2)
(INCHES)

5 kV AND 8 kV, UL TYPE MV-105, 133%/100% INS. LEVELS, 115 MILS
17001.120605
17001.120405
17001.120205
17001.120105*
17001.125105
17001.125205
17001.125305*
17001.135405
17001.136005
17001.136205
17001.136505
17001.137005
17001.637505

6
4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

0.17
0.22
0.27
0.31
0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

0.415
0.455
0.510
0.545
0.580
0.620
0.665
0.720
0.770
0.870
0.990
1.170
1.320

0.490
0.535
0.590
0.620
0.655
0.695
0.745
0.795
0.850
0.945
1.065
1.250
1.400

0.060
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080

1.52
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03

0.65
0.70
0.76
0.79
0.82
0.86
0.94
1.00
1.05
1.14
1.27
1.45
1.60

16.51
17.15
19.05
20.07
21.08
22.10
24.38
25.65
27.18
29.72
33.53
38.35
42.42

295
365
471
539
623
728
886
1053
1199
1559
2088
2962
3815

439
543
701
802
927
1083
1318
1567
1784
2320
3107
4407
5677

126
178
259
315
386
474
585
725
849
1165
1639
2427
3210

188
265
385
468
575
706
871
1080
1263
1735
2439
3611
4777

93
120
165
190
215
255
290
330
365
440
535
655
755

97
125
165
185
215
245
275
315
345
415
500
610
690

2
2.5
2.5
2.5
3
3
3
3
3.5
3.5
4
5
5

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6160

March, 2012

Aluminum Uniblend LF
®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils
Features (cont’d.):

•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:
Product Construction:
Conductor:

•	6 AWG thru 1000 kcmil 1350 aluminum compact
Class B STRANDFILL® blocked conductor

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

	 THICKNESS) EPR TYPE MV-105 (VOLTAGE) KV%
INSULATION LEVEL SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK
* Sizes smaller than 1/0 AWG do not include
“FOR CT USE”.

Applications:

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Low-friction, lead-free, flame-retardant, moistureand sunlight-resistant Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) COMPACT AL
UNIBLEND ® LF PVC JKT (INSULATION

CATALOG
NUMBER

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Print (cont’d.):

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
•	For use in wet or dry locations when installed in
accordance with NEC
•	For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

Features:

•	Rated at 105˚C
•	Lower coefficient of friction for ease of
installation
•	Meets longitudinal water penetration resistance
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling

NOMINAL INSULATION NOMINAL
COND. CONDUCTOR
CONDUIT
NOMINAL CABLE
AMPACITY
JACKET
SIZE DIAMETER DIAMETER
SIZING
INCHES
THICKNESS
ALUMINUM
WEIGHT
COPPER
WEIGHT
DIAMETER
WEIGHT
(AWG/
CONDUIT UNDERGROUND (3)
kcmil) INCHES MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1) DUCT (2) (INCHES)

5 kV AND 8 kV, UL TYPE MV-105, 133%/100% INS. LEVELS, 115 MILS
17001.120608*
17001.120408*
17001.120208*
17001.120108*
17001.125108*
17001.125208*
17001.125308*
17001.135408*
17001.136008*
17001.136208
17001.136508
17001.137008
17001.137508

6
4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

0.17
0.22
0.27
0.31
0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

0.415
0.455
0.510
0.545
0.580
0.620
0.665
0.720
0.770
0.870
0.990
1.170
1.320

0.490
0.535
0.590
0.620
0.655
0.695
0.745
0.795
0.850
0.945
1.065
1.250
1.400

0.060
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080

1.52
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03

0.65
0.70
0.76
0.79
0.82
0.86
0.94
1.00
1.05
1.14
1.27
1.45
1.60

16.51
17.15
19.05
20.07
21.08
22.10
24.38
25.65
27.18
29.72
33.53
38.35
42.42

239
275
328
359
396
442
526
599
661
807
1012
1349
1664

356
409
488
534
590
658
783
891
984
1201
1506
2008
2476

25
39
62
78
99
125
158
199
234
329
468
703
937

37
58
92
116
147
186
235
296
348
490
696
1046
1394

45
49
54
57
60
63
67
72
77
84
95
111
122

67
73
81
84
90
94
100
107
115
125
141
165
182

72
94
130
150
170
200
225
260
290
350
430
540
640

75
98
130
145
165
190
215
245
270
330
400
490
565

2
2.5
2.5
2.5
3
3
3
3
3.5
3.5
4
5
5

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 105°C (221°F) and
an ambient air temperature of 40°C (104°F).
(2) Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor
temperature of 105°C (221°F) and an ambient earth temperature of 20°C (68°F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6175
March, 2012

Uniblend

®

EPR/Copper Tape Shield/CPE, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils
Product Construction:
Conductor:

•	6 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Chlorinated Polyethylene (CPE)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) COMPACT CU
UNIBLEND ® CPE JKT (INSULATION THICKNESS)
EPR TYPE MV-105 (VOLTAGE) KV% INSULATION
LEVEL SUN RES FOR CT USE (UL) SEQUENTIAL
FOOTAGE MARK
* Sizes smaller than 1/0 AWG do not include
“FOR CT USE”.

Options:

• Other jacket options available upon request
• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610

CATALOG
NUMBER

NOMINAL
COND. CONDUCTOR
SIZE DIAMETER
(AWG/
kcmil) INCHES

Applications:

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
•	For use in wet or dry locations when installed in
accordance with NEC
•	For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Features:

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

INSULATION
NOMINAL
DIAMETER
JACKET
INCHES
THICKNESS
MIN. MAX. INCHES mm

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL CABLE
AMPACITY
CONDUIT
COPPER WEIGHT
DIAMETER
WEIGHT
CONDUIT UNDERGROUND SIZING (3)
IN
mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1)
DUCT (2)
(INCHES)

5 kV AND 8 kV, UL TYPE MV-105, 133%/100% INS. LEVELS, 115 MILS
17101.120600*
17101.120400*
17101.120200*
17101.120100*
17101.125100*
17101.125200*
17101.125300*
17101.135400*
17101.136000*
17101.136200*
17101.136500*
17101.137000*
17101.137500*

6
4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

0.17
0.22
0.27
0.31
0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

0.415
0.455
0.510
0.545
0.580
0.620
0.665
0.720
0.770
0.870
0.990
1.170
1.320

0.490
0.535
0.590
0.620
0.655
0.695
0.745
0.795
0.850
0.945
1.065
1.250
1.400

0.060
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080

1.52
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03

0.65
0.70
0.76
0.79
0.82
0.86
0.94
1.00
1.05
1.14
1.27
1.45
1.60

16.51
17.15
19.05
20.07
21.08
22.10
24.38
25.65
27.18
29.72
33.53
38.35
42.42

293
363
469
537
621
726
883
1049
1195
1555
2083
2981
3808

436
540
698
799
924
1080
1314
1561
1778
2314
3100
4436
5666

126
178
259
315
386
474
585
725
849
1165
1639
2427
3210

188
265
385
468
575
706
871
1080
1263
1735
2439
3611
4777

93
120
165
190
215
255
290
330
365
440
535
655
755

97
125
165
185
215
245
275
315
345
415
500
610
690

2
2.5
2.5
2.5
3
3
3
3
3.5
3.5
4
5
5

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6180

March, 2012

GenFree Uniblend
®

®

EPR/Copper Tape Shield/LSZH, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105/ST1, 133%/100% Ins. Levels, 115 Mils
Features (cont’d.):

•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Product Construction:
Conductor:

•	6 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Overall Jacket:

•	Lead-free, moisture- and sunlight-resistant
Low-Smoke, Zero-Halogen Polyolefin (LSZH)

	 * Sizes smaller than 1/0 AWG do not include
“FOR CT USE”.

Options:

• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610

Applications:

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
•	For use in wet or dry locations when installed in
accordance with NEC
•	For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	ICEA T-33-655
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	UL 1685 Vertical Flame and Smoke Release Test
• Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)

Packaging:

Features:

INSULATION
NOMINAL
DIAMETER
JACKET
INCHES
THICKNESS
MIN. MAX. INCHES mm

NOMINAL CABLE
AMPACITY
CONDUIT
COPPER WEIGHT
DIAMETER
WEIGHT
CONDUIT UNDERGROUND SIZING (3)
INCHES
mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1)
DUCT (2)
(INCHES)

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) COMPACT CU
GENFREE® UNIBLEND ® LSZH JKT (INSULATION

NOMINAL
COND. CONDUCTOR
SIZE DIAMETER
(AWG/
kcmil) INCHES

	 THICKNESS) EPR TYPE MV-105/ST1 (VOLTAGE)
KV% INSULATION LEVEL SUN RES FOR CT USE
(UL) SEQUENTIAL FOOTAGE MARK

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

Print:

CATALOG
NUMBER

Compliances:

Print (cont’d.):

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance

5 kV AND 8 kV, UL TYPE MV-105/ST1, 133%/100% INS. LEVELS, 115 MILS
17201.120600*
17201.120400*
17201.120200
17201.120100*
17201.125100
17201.125200
17201.125300*
17201.135400
17201.136000*
17201.136200
17201.136500
17201.137000
17201.637500*

6
4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

0.17
0.22
0.27
0.31
0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

0.415
0.455
0.510
0.545
0.580
0.620
0.665
0.720
0.770
0.870
0.990
1.170
1.320

0.490
0.535
0.590
0.620
0.655
0.695
0.745
0.795
0.850
0.945
1.065
1.250
1.400

0.060
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080
0.080

1.52
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03
2.03

0.65
0.70
0.76
0.79
0.82
0.86
0.94
1.00
1.05
1.14
1.27
1.45
1.60

16.51
17.15
19.05
20.07
21.08
22.10
24.38
25.65
27.18
29.72
33.53
38.35
42.42

295
365
471
539
623
728
886
1053
1199
1559
2088
2962
3815

439
543
701
802
927
1083
1318
1567
1784
2320
3107
4407
5677

126
178
259
315
386
474
585
725
849
1165
1639
2427
3210

188
265
385
468
575
706
871
1080
1263
1735
2439
3611
4777

93
120
165
190
215
255
290
330
365
440
535
655
755

97
125
165
185
215
245
275
315
345
415
500
610
690

2
2.5
2.5
2.5
3
3
3
3
3.5
3.5
4
5
5

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6200

January, 2011

Copper Wire Shield

TRXLPE/Copper Wire Shield/PVC, Medium-Voltage Power
5 kV, UL Type MV-105, 100% Ins. Level, 90 Mils
Product Construction:
Conductor:

• 6 AWG thru 1000 kcmil annealed bare copper
Class B compressed strand in accordance with
ASTM B3 and B8

Extruded Strand Shield (ESS):

• Extruded thermoset semi-conducting stress
control layer over conductor

Options:

Insulation:

• Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Extruded Insulation Shield (EIS):

• Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• A concentric serve of 24 AWG annealed solid
bare copper wires over which shall be applied a
lapped non-metallic tape

Jacket:

• Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) CU (INSULATION
THICKNESS) TRXLPE TYPE MV-105 (VOLTAGE)
KV% INSULATION LEVEL SUN RES (UL)
SEQUENTIAL FOOTAGE MARK

CATALOG
NUMBER

•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC and in accordance with UL 1685
(70,000 BTU/hr)
•	STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610

Applications:

•	For use in wet or dry locations when installed in
accordance with NEC
•	For use in aerial, conduit, open tray and
underground duct installations where cost
effectiveness is a factor
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Features:

•	Rated at 105˚C
•	Triple tandem extrusion of the strand shield,
insulation and insulation shield provides a
virtually perfect cable core
•	Excellent resistance to electro-chemical treeing,
heat, moisture and a wide variety of industrial
chemicals

NOMINAL
COND. CONDUCTOR
SIZE DIAMETER
(AWG/
kcmil) INCHES

INSULATION
NOMINAL
DIAMETER
JACKET
INCHES
THICKNESS
MIN. MAX. INCHES mm

6
4
2
1/0
2/0
4/0
250
350
500
750
1000

0.370
0.420
0.475
0.555
0.600
0.705
0.760
0.865
0.990
1.180
1.325

Features (cont’d.):

•	PVC jacket provides mechanical protection of the
shielding system during installation, as well as
protection from many industrial chemicals
•	Sunlight-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL 1072
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and plexing

NOMINAL CABLE
COPPER WEIGHT
DIAMETER
WEIGHT
INCHES
mm LBS/1000 FT kg/km LBS/1000 FT kg/km

AMPACITY

CONDUIT
CONDUIT UNDERGROUND SIZING (3)
IN AIR (1)
DUCT (2)
(INCHES)

5 kV, UL TYPE MV-105, 100% INS. LEVELS, 90 MILS
17241.010600*
17241.010400*
17241.010200*
17241.015100*
17241.015200*
17241.015400*
17241.016000*
17241.016200*
17241.016500*
17241.017000*
17241.017500*

0.18
0.23
0.29
0.37
0.41
0.52
0.56
0.67
0.80
0.97
1.12

0.445
0.495
0.555
0.630
0.675
0.780
0.835
0.940
1.070
1.255
1.405

0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080

1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.03

0.67
0.72
0.77
0.85
0.89
1.04
1.10
1.20
1.36
1.53
1.66

17.02
18.29
19.55
21.59
22.61
26.42
28.19
30.48
34.54
38.86
42.16

250
317
420
580
670
1000
1155
1505
2060
2868
3684

372
472
625
863
997
1488
1719
2240
3066
4268
5482

93
141
217
338
427
669
788
1097
1563
2340
3113

138
210
323
503
635
996
1173
1632
2325
3482
4632

84
110
145
200
225
305
355
430
530
665
770

92
120
155
210
235
310
345
415
505
630
720

2.5
2.5
2.5
3
3
3.5
3.5
4
5
5
6

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
Note: The NESC Lighting bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6250

March, 2012

Uniblend

®

EPR/Copper Tape Shield with Overall PVC Jacket, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils, Three Conductor
Features:

Product Construction:
Conductor:

Print:

•	6 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Options:

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

Grounding Conductor:

•	1 bare grounding conductor may be in contact
with metallic shielding tape

Overall Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC)

NOMINAL
COND. CONDUCTOR
SIZE DIAMETER
(AWG/
kcmil) INCHES

• Other jacket options available upon request
• Jacketed singles
• UniShield® singles
• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610
• 3 bare copper ground wires
• Covered ground wires

Applications:

• 5 mil annealed copper tape with an
overlap of 25%

CATALOG
NUMBER

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
3/C SIZE (AWG OR KCMIL) COMPACT CU
UNIBLEND ® PVC JKT (INSULATION THICKNESS)
EPR TYPE MV-105 (VOLTAGE) KV% INSULATION
LEVEL DIR BUR SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK

• Suited for use in a broad range of commercial,
industrial and utility applications, where reliability
is the major concern, space is limited and ease of
installation is critical
• In wet or dry locations when installed in
accordance with NEC
• In aerial, direct burial, conduit, open tray and
underground duct installations

INSULATION
NOMINAL
DIAMETER
OVERALL JKT.
GROUND
INCHES
THICKNESS
WIRE
MIN. MAX. (AWG) INCHES mm

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (70,000 BTU/hr)
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• IEEE 1202 (70,000 BTU/hr)/CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and plexing

NOMINAL CABLE
AMPACITY
COPPER WEIGHT
DIAMETER
WEIGHT
CONDUIT UNDERGROUND
INCHES
mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1)
DUCT (2)

5 kV AND 8 kV, UL TYPE MV-105, 133%/100% INS. LEVELS, 115 MILS, THREE CONDUCTOR
15493.400600* 6
15493.400400* 4
15493.400200* 2
15493.405100* 1/0
15493.405200* 2/0
15493.405400* 4/0
15493.406000* 250
15493.406200* 350
15493.406500* 500
15493.407000* 750
15493.407500* 1000

0.17
0.22
0.27
0.34
0.38
0.48
0.53
0.62
0.74
0.91
1.06

0.415
0.455
0.510
0.580
0.620
0.720
0.770
0.870
0.990
1.170
1.320

0.490
0.535
0.590
0.655
0.695
0.795
0.850
0.945
1.065
1.250
1.400

6
6
6
4
4
3
2
2
1
1/0
2/0

0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110
0.140
0.140

2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79
3.56
3.56

1.29
1.39
1.51
1.67
1.82
2.07
2.15
2.36
2.64
3.14
3.48

32.77
35.31
38.35
42.42
46.23
52.58
54.61
59.94
67.06
79.76
88.39

939
1158
1511
2030
2449
3438
3968
5009
6793
9833
12601

1397
1723
2249
3021
3645
5116
5904
7454
10065
14633
18753

460
616
860
1290
1556
2344
2759
3713
5191
7629
10070

685
917
1279
1919
2315
3488
4105
5525
7724
11352
14985

92
120
165
215
245
320
350
430
525
635
725

95
125
160
210
235
305
335
400
485
585
660

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(75) of the NEC for three conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an ambient air
temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(79) of the NEC for three conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature of 105˚C (221˚F)
and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
Note: a) All sizes are “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6255

March, 2012

Uniblend LF EPR/Copper Tape Shield with Overall PVC Jacket
®

Medium-Voltage Power, Shielded, 5 kV and 8 kV, UL Type MV-105
133%/100% Ins. Levels, 115 Mils, Three Conductor

Product Construction:
Conductor:

•	6 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

Options:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Grounding Conductor:

•	1 bare grounding conductor may be in contact
with metallic shielding tape

Overall Jacket:

•	Low-friction, lead-free, flame-retardant, moistureand sunlight-resistant Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/
YR OF MANUFACTURE) LIGHTNING BOLT
SYMBOL 3/C SIZE (AWG OR KCMIL) COMPACT
CU UNIBLEND ® LF PVC JKT (INSULATION
THICKNESS) EPR TYPE MV-105 (VOLTAGE) KV%
INSULATION LEVEL DIR BUR SUN RES FOR CT
USE (UL) SEQUENTIAL FOOTAGE MARK

NOMINAL
COND. CONDUCTOR
SIZE DIAMETER
(AWG/
kcmil) INCHES

CATALOG
NUMBER

• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610
• 3 bare copper ground wires
• Covered ground wires

Applications:

• Suited for use in a broad range of commercial,
industrial and utility applications, where reliability
is the major concern, space is limited and ease of
installation is critical
• In wet or dry locations when installed in
accordance with NEC
• In aerial, direct burial, conduit, open tray and
underground duct installations

Features:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (70,000 BTU/hr)
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• IEEE 1202 (70,000 BTU/hr)/CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Rated at 105˚C
•	Lower coefficient of friction for ease of
installation
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

INSULATION
NOMINAL
DIAMETER
OVERALL JKT.
GROUND
INCHES
THICKNESS
WIRE
MIN. MAX. (AWG) INCHES mm

Compliances:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and plexing

NOMINAL CABLE
AMPACITY
COPPER WEIGHT
DIAMETER
WEIGHT
CONDUIT UNDERGROUND
INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1)
DUCT (2)

5 kV AND 8 kV, UL TYPE MV-105, 133%/100% INS. LEVELS, 115 MILS, THREE CONDUCTOR
15493.400605
15493.400405
15493.400205
15493.405105
15493.405205
15493.405405
15493.406005*
15493.406205
15493.406505
15493.407005*
15493.407505*

6
4
2
1/0
2/0
4/0
250
350
500
750
1000

0.17
0.22
0.27
0.34
0.38
0.48
0.53
0.62
0.74
0.91
1.06

0.415
0.455
0.510
0.580
0.620
0.720
0.770
0.870
0.990
1.170
1.320

0.490
0.535
0.590
0.655
0.695
0.795
0.850
0.945
1.065
1.250
1.400

6
6
6
4
4
3
2
2
1
1/0
2/0

0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110
0.140
0.140

2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79
3.56
3.56

1.29
1.39
1.51
1.67
1.82
2.07
2.15
2.36
2.64
3.14
3.48

32.77
35.31
38.35
42.42
46.23
52.58
54.61
59.94
67.06
79.76
88.39

939
1158
1511
2030
2449
3438
3968
5009
6793
9833
12601

1397
1723
2249
3021
3645
5116
5904
7454
10065
14633
18753

460
616
860
1290
1556
2344
2759
3713
5191
7629
10070

685
917
1279
1919
2315
3488
4105
5525
7724
11352
14985

92
120
165
215
245
320
350
430
525
635
725

95
125
160
210
235
305
335
400
485
585
660

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(75) of the NEC for three conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an ambient air
temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(79) of the NEC for three conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature of 105˚C (221˚F)
and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
Note: a) All sizes are “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6275

March, 2012

Uniblend

®

EPR/Copper Tape Shield with Overall CPE Jacket, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils, Three Conductor
Features:

Product Construction:
Conductor:

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
3/C SIZE (AWG OR KCMIL) COMPACT CU
UNIBLEND ® CPE JKT (INSULATION THICKNESS)
EPR TYPE MV-105 (VOLTAGE) KV% INSULATION
LEVEL DIR BUR SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK

•	6 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (70,000 BTU/hr)
•	OSHA Acceptable
Optional Flame Tests:
• IEEE 1202 (70,000 BTU/hr)/CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)

Options:

Insulation:

• Other jacket options available upon request
• Jacketed singles
• UniShield® singles
• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610
• 3 bare copper ground wires
• Covered ground wires

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

Packaging:

Applications:

• 5 mil annealed copper tape with an
overlap of 25%

• Suited for use in a broad range of commercial,
industrial and utility applications, where reliability
is the major concern, space is limited and ease of
installation is critical
• In wet or dry locations when installed in
accordance with NEC
• In aerial, direct burial, conduit, open tray and
underground duct installations

Grounding Conductor:

•	1 bare grounding conductor may be in contact
with metallic shielding tape

Overall Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Chlorinated Polyethylene (CPE)

CATALOG
NUMBER

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

NOMINAL INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
DIAMETER GROUND OVERALL JKT.
SIZE DIAMETER
INCHES
THICKNESS
DIAMETER
WEIGHT
(AWG/
WIRE
kcmil) INCHES
MIN. MAX. (AWG) INCHES mm INCHES mm LBS/1000 FT kg/km

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and plexing

AMPACITY
COPPER WEIGHT
LBS/1000 FT kg/km

CONDUIT UNDERGROUND
IN AIR (1)
DUCT (2)

5 kV AND 8 kV, UL TYPE MV-105, 133%/100% INS. LEVELS, 115 MILS, THREE CONDUCTOR
15593.400600*
15593.400400*
15593.400200*
15593.405100*
15593.405200*
15593.405400*
15593.406000*
15593.406200*
15593.406500*
15593.407000*
15593.407500*

6
4
2
1/0
2/0
4/0
250
350
500
750
1000

0.17
0.22
0.27
0.34
0.38
0.48
0.53
0.62
0.74
0.91
1.06

0.415
0.455
0.510
0.580
0.620
0.720
0.770
0.870
0.990
1.170
1.320

0.490
0.535
0.590
0.655
0.695
0.795
0.850
0.945
1.065
1.250
1.400

6
6
6
4
4
3
2
2
1
1/0
2/0

0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110
0.140
0.140

2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79
3.56
3.56

1.29
1.39
1.51
1.67
1.82
2.07
2.15
2.36
2.64
3.14
3.48

32.77
35.31
38.35
42.42
46.23
52.58
54.61
59.94
67.06
79.76
88.39

939
1158
1511
2030
2449
3438
3968
5009
6793
9833
12601

1397
1723
2249
3021
3645
5116
5904
7454
10065
14633
18753

460
616
860
1290
1556
2344
2759
3713
5191
7629
10070

685
917
1279
1919
2315
3488
4105
5525
7724
11352
14985

92
120
165
215
245
320
350
430
525
635
725

95
125
160
210
235
305
335
400
485
585
660

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(75) of the NEC for three conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an ambient air
temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(79) of the NEC for three conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature of 105˚C (221˚F)
and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
Note: a) Sizes smaller than 4/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6280

March, 2012

GenFree Uniblend
®

®

EPR/Copper Tape Shield with Overall LSZH Jacket, Medium-Voltage Power, Shielded
5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils, Three Conductor
Product Construction:
Conductor:

•	6 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Options:

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

• Suited for use in a broad range of commercial,
industrial and utility applications, where reliability
is the major concern, space is limited and ease of
installation is critical
• In wet or dry locations when installed in
accordance with NEC
• In aerial, direct burial, conduit, open tray and
underground duct installations

• 5 mil annealed copper tape with an overlap
of 25%

Grounding Conductor:

•	1 bare grounding conductor may be in contact
with metallic shielding tape
•	Lead-free, moisture- and sunlight-resistant
Low-Smoke, Zero-Halogen Polyolefin (LSZH)

Packaging:

Features:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and plexing

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
3/C SIZE (AWG OR KCMIL) COMPACT CU
GENFREE® UNIBLEND ® LSZH JKT (INSULATION
THICKNESS) EPR TYPE MV-105 (VOLTAGE) KV%
INSULATION LEVEL DIR BUR SUN RES FOR CT
USE (UL) SEQUENTIAL FOOTAGE MARK

CATALOG
NUMBER

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	ICEA T-33-655
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (70,000 BTU/hr)
•	OSHA Acceptable
Optional Flame Tests:
• IEEE 1202 (70,000 BTU/hr)/CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)

Applications:

Metallic Shield:

Overall Jacket:

Compliances:

• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610
• 3 bare copper ground wires
• Covered ground wires

NOMINAL INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
DIAMETER GROUND OVERALL JKT.
SIZE DIAMETER
INCHES
THICKNESS
DIAMETER
WEIGHT
(AWG/
WIRE
kcmil) INCHES
MIN. MAX. (AWG) INCHES mm INCHES mm LBS/1000 FT kg/km

AMPACITY
COPPER WEIGHT
LBS/1000 FT kg/km

CONDUIT UNDERGROUND
IN AIR (1)
DUCT (2)

5 kV AND 8 kV, UL TYPE MV-105, 133%/100% INS. LEVELS, 115 MILS, THREE CONDUCTOR
15693.400600*
15693.400400*
15693.400200*
15693.405100*
15693.405200*
15693.405400*
15693.406000*
15693.406200*
15693.406500*
15693.407000*
15693.407500*

6
4
2
1/0
2/0
4/0
250
350
500
750
1000

0.17
0.22
0.27
0.34
0.38
0.48
0.53
0.62
0.74
0.91
1.06

0.415
0.455
0.510
0.580
0.620
0.720
0.770
0.870
0.990
1.170
1.320

0.490
0.535
0.590
0.655
0.695
0.795
0.850
0.945
1.065
1.250
1.400

6
6
6
4
4
3
2
2
1
1/0
2/0

0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110
0.140
0.140

2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79
3.56
3.56

1.29
1.39
1.51
1.67
1.82
2.07
2.15
2.36
2.64
3.14
3.48

32.77
35.31
38.35
42.42
46.23
52.58
54.61
59.94
67.06
79.76
88.39

939
1158
1511
2030
2449
3438
3968
5009
6793
9833
12601

1397
1723
2249
3021
3645
5116
5904
7454
10065
14633
18753

460
616
860
1290
1556
2344
2759
3713
5191
7629
10070

685
917
1279
1919
2315
3488
4105
5525
7724
11352
14985

92
120
165
215
245
320
350
430
525
635
725

95
125
160
210
235
305
335
400
485
585
660

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(75) of the NEC for three conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an ambient air
temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(79) of the NEC for three conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature of 105˚C (221˚F)
and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6300
June, 2013

UniShield

®

EPR/Copper Wire Shield/CPE, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils
Features (cont’d.):

•	Flexibility for easy handling
•	High dielectric strength
•	Low dielectric loss
•	Low moisture absorption
•	Electrical stability under stress
•	Chemical-resistant
•	Sunlight-resistant
•	Meets cold bend test at -55˚C

Product Construction:
Conductor:

•	Installed in a broad range of commercial,
industrial and utility projects such as pulp
and paper mills, petrochemical plants, steel
mills, textile mills, water and sewage treatment
facilities, environmental protection systems,
railroads, mines and fossil fuel utility generating
stations
•	Suitable for use in wet or dry locations when
installed in accordance with NEC
•	For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system
with a ground conductor that is in close
proximity, and conforms with NEC 250.4(A)(5)

•	2 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with black conducting shield
layers

Composite Insulation Shield
and Jacket:

•	Six corrugated copper drain wires embedded in
composite layers of semi-conducting thermoset
copolymer and semi-conducting black flameretardant Chlorinated Polyethylene (CPE)

Features:

•	Rated at 105˚C
•	Reduced conductor size and shield system
provides the smallest premium medium-voltage
shielded power cable with full insulation
•	Smaller outside dimensions reduce the size of
duct needed or increase the ampacity per duct
•	All features contribute to faster and
easier installation
•	Superior cold bend and cold impact
performance
•	Stable and constant shield short
circuit performance
•	Excellent heat and moisture resistance
•	Outstanding corona resistance

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/
YR OF MANUFACTURE) LIGHTNING BOLT
SYMBOL 1/C SIZE (AWG OR KCMIL) COMPACT
CU UNISHIELD ® (INSULATION THICKNESS)
EPR DRTP SEMI-CON CPE JKT TYPE MV-105
(VOLTAGE) KV% INSULATION LEVEL SUN RES
FOR CT USE (UL) SEQUENTIAL FOOTAGE MARK
* Sizes smaller than 1/0 AWG do not include
“FOR CT USE”.

CATALOG
NUMBER

Compliances:

Applications:

NOMINAL
COND. CONDUCTOR
SIZE DIAMETER
(AWG/
kcmil) INCHES

INSULATION
DIAMETER
INCHES
MIN. MAX.

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on nonreturnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and triplexing
	 NOTE: Due to the semi-conducting properties of the

cable jacket, multi-point grounding is recommended for
all UniShield® installations.

DRAIN
NOMINAL CABLE
WIRE
COPPER WEIGHT
DIAMETER
WEIGHT
SIZE
(AWG) INCHES
mm LBS/1000 FT kg/km LBS/1000 FT kg/km

AMPACITY
CONDUIT
CONDUIT UNDERGROUND TRAY SIZING (4)
IN AIR (1)
DUCT (2)
(3) (INCHES)

15 kV ¥ , UL TYPE MV-105, 133% INS. LEVEL, 220 MILS
2
19161.660200
19161.675100 1/0
19161.675200 2/0
19161.665300* 3/0
19161.675400 4/0
19161.686000 250
19161.686200 350
19161.686500 500
19161.697000 750
19161.307500* 1000

0.27
0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

0.710
0.780
0.820
0.865
0.920
0.970
1.070
1.190
1.370
1.520

0.800
0.865
0.905
0.955
1.005
1.060
1.155
1.275
1.460
1.610

19
18
18
18
18
17
17
17
16
16

0.93
1.01
1.05
1.10
1.16
1.23
1.33
1.46
1.67
1.86

23.88
25.91
27.18
28.45
29.72
31.50
33.78
37.08
42.42
47.24

555
734
844
978
1151
1325
1691
2238
3174
4122

835
1102
1259
1458
1716
1984
2530
3344
4739
6133

230
358
443
550
685
813
1122
1585
2368
3138

342
533
659
818
1019
1210
1669
2358
3523
4669

165
215
255
290
330
365
440
535
655
755

165
215
245
275
315
345
415
500
610
690

220
250
290
335
370
460
575
745
890

3
3.5
3.5
3.5
4
4
5
5
6
6

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F);
the ampacities are based on 75% of the values per Table 310.60(C)(69). For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values shown above.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
¥100% insulation level is available upon request
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all UniShield® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6350
March, 2012

Uniblend

®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils
Product Construction:
Conductor:

•	2 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) COMPACT CU
UNIBLEND ® PVC JKT (INSULATION THICKNESS)
EPR TYPE MV-105 (VOLTAGE) KV% INSULATION
LEVEL SUN RES FOR CT USE (UL) SEQUENTIAL
FOOTAGE MARK
*S
 izes smaller than 1/0 AWG do not include
“FOR CT USE”.

Options:

• Other jacket options available upon request
• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610
•	100% insulation level

CATALOG
NUMBER

NOMINAL
COND. CONDUCTOR
SIZE DIAMETER
(AWG/
kcmil) INCHES

Applications:

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
• For use in wet or dry locations when installed in
accordance with NEC
• For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Features:

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

INSULATION
NOMINAL
NOMINAL CABLE
AMPACITY
DIAMETER
JACKET
CONDUIT
INCHES
THICKNESS
COPPER WEIGHT CONDUIT UNDERGROUND TRAY SIZING
DIAMETER
WEIGHT
(4)
MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1) DUCT (2)
(3) (INCHES)

15 kV ¥ , UL TYPE MV-105, 133% INS. LEVEL, 220 MILS
17031.130200*
17031.130100*
17031.135100*
17031.135200*
17031.135300*
17031.135400*
17031.136000*
17031.136200*
17031.136500*
17031.137000*
17031.137500*

2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

0.27
0.31
0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

0.710
0.745
0.780
0.820
0.865
0.920
0.970
1.070
1.190
1.370
1.520

0.800
0.830
0.865
0.905
0.955
1.005
1.060
1.155
1.275
1.460
1.610

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110

2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79

0.99
1.02
1.06
1.10
1.14
1.21
1.25
1.35
1.47
1.65
1.86

25.14
25.91
26.92
27.94
28.95
30.73
31.75
34.29
37.34
41.91
47.24

658
733
825
938
1078
1261
1407
1783
2331
3234
4219

979
1090
1228
1396
1604
1876
2093
2653
3468
4812
6278

276
332
403
492
603
743
866
1184
1657
2445
3228

411
494
600
732
897
1105
1289
1761
2466
3638
4803

165
190
215
255
290
330
365
440
535
655
755

165
185
215
245
275
315
345
415
500
610
690

220
250
290
335
370
460
575
745
890

3
3.5
3.5
3.5
3.5
3.5
4
5
5
6
6

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F);
the ampacities are based on 75% of the values per Table 310.60(C)(69). For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values shown above.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
¥100% insulation level is available upon request
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6355
April, 2011

Uniblend LF
®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils
Features (cont’d.):

Product Construction:
Conductor:

Print (cont’d.):

	 THICKNESS) EPR TYPE MV-105 (VOLTAGE) KV%
INSULATION LEVEL SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK

•	2 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Options:

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610
•	100% insulation level

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Applications:

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Low-friction, lead-free, flame-retardant, moistureand sunlight-resistant Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) COMPACT CU
UNIBLEND ® LF PVC JKT (INSULATION

NOMINAL
COND. CONDUCTOR
SIZE DIAMETER
(AWG/
kcmil) INCHES

Compliances:

*S
 izes smaller than 1/0 AWG do not include
“FOR CT USE”.

Extruded Strand Shield (ESS):

CATALOG
NUMBER

•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
• For use in wet or dry locations when installed in
accordance with NEC
• For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

Features:

•	Rated at 105˚C
•	Lower coefficient of friction for ease of
installation
•	Excellent heat and moisture resistance

INSULATION
NOMINAL
NOMINAL CABLE
AMPACITY
DIAMETER
JACKET
CONDUIT
INCHES
THICKNESS
COPPER WEIGHT CONDUIT UNDERGROUND TRAY SIZING
DIAMETER
WEIGHT
(4)
MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1) DUCT (2)
(3) (INCHES)

15 kV ¥ , UL TYPE MV-105, 133% INS. LEVEL, 220 MILS
2
17031.130205
17031.130105* 1
1/0
17031.135105
2/0
17031.135205
17031.135305* 3/0
4/0
17031.135405
17031.136005 250
17031.136205 350
17031.136505 500
17031.137005 750
17031.137505 1000

0.27
0.31
0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

0.710
0.745
0.780
0.820
0.865
0.920
0.970
1.070
1.190
1.370
1.520

0.800
0.830
0.865
0.905
0.955
1.005
1.060
1.155
1.275
1.460
1.610

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110

2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79

0.99
1.02
1.06
1.10
1.14
1.21
1.25
1.35
1.47
1.65
1.86

25.14
25.91
26.92
27.94
28.95
30.73
31.75
34.29
37.34
41.91
47.24

658
733
825
938
1078
1261
1407
1783
2331
3234
4219

979
1090
1228
1396
1604
1876
2093
2653
3468
4812
6278

276
332
403
492
603
743
866
1184
1657
2445
3228

411
494
600
732
897
1105
1289
1761
2466
3638
4803

165
190
215
255
290
330
365
440
535
655
755

165
185
215
245
275
315
345
415
500
610
690

220
250
290
335
370
460
575
745
890

3
3.5
3.5
3.5
3.5
3.5
4
5
5
6
6

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F);
the ampacities are based on 75% of the values per Table 310.60(C)(69). For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values shown above.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
¥100% insulation level is available upon request
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6360

April, 2011

Aluminum Uniblend LF
®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils
Product Construction:
Conductor:

•	2 AWG thru 1000 kcmil 1350 aluminum compact
Class B STRANDFILL® blocked conductor

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

Applications:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Low-friction, lead-free, flame-retardant, moistureand sunlight-resistant Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/
YR OF MANUFACTURE) LIGHTNING BOLT
SYMBOL 1/C SIZE (AWG OR KCMIL) COMPACT
AL UNIBLEND ® LF PVC JKT (INSULATION
THICKNESS) EPR TYPE MV-105 (VOLTAGE) KV%
INSULATION LEVEL SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK
*S
 izes smaller than 1/0 AWG do not include
“FOR CT USE”.

Options:

•	100% insulation level

CATALOG
NUMBER

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
• For use in wet or dry locations when installed in
accordance with NEC
• For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Features:

•	Rated at 105˚C
•	Lower coefficient of friction for ease of
installation
•	Meets longitudinal water penetration resistance
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL INSULATION
NOMINAL
COND. CONDUCTOR
CONDUIT
NOMINAL CABLE
AMPACITY
JACKET
SIZE DIAMETER DIAMETER
SIZING
INCHES
THICKNESS
ALUMINUM
WEIGHT
COPPER
WEIGHT
DIAMETER
WEIGHT
(AWG/
CONDUIT UNDERGROUND TRAY (4)
kcmil) INCHES MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1) DUCT (2)
(3) (INCHES)

15 kV ¥ , UL TYPE MV-105, 133% INS. LEVEL, 220 MILS
17031.130208*
17031.130108*
17031.135108*
17031.135208*
17031.135308*
17031.135408*
17031.136008*
17031.136208
17031.136508
17031.137008
17031.137508

2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

0.27
0.31
0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

0.710
0.745
0.780
0.820
0.865
0.920
0.970
1.070
1.190
1.370
1.520

0.800
0.830
0.865
0.905
0.955
1.005
1.060
1.155
1.275
1.460
1.610

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110

2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79

0.99
1.02
1.06
1.10
1.14
1.21
1.25
1.35
1.47
1.65
1.86

25.14
25.91
26.92
27.94
28.95
30.73
31.75
34.29
37.34
41.91
47.24

515
553
598
652
718
807
869
1031
1255
1621
2068

767
822
890
970
1068
1201
1293
1534
1868
2412
3078

62
78
99
125
158
199
234
329
468
703
937

92
116
147
186
235
296
348
490
696
1046
1394

71
74
77
81
85
90
94
103
113
129
140

106
110
115
121
126
134
140
153
168
192
208

130
150
170
200
225
260
290
350
430
540
640

130
145
165
190
215
245
270
330
400
490
565

—
—
170
195
225
265
290
360
450
585
705

3
3.5
3.5
3.5
3.5
3.5
4
5
5
6
6

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 105°C (221°F) and
an ambient air temperature of 40°C (104°F).
(2) Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor
temperature of 105°C (221°F) and an ambient earth temperature of 20°C (68°F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40°C (104°F);
the ampacities are based on 75% of the values per Table 310.60(C)(70). For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values shown above.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
¥100% insulation level is available upon request.
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6375
April, 2011

Uniblend

®

EPR/Copper Tape Shield/CPE, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils
Features:

Product Construction:
Conductor:

Print (cont’d.):

	 UNIBLEND ® CPE JKT (INSULATION THICKNESS)
EPR TYPE MV-105 (VOLTAGE) KV% INSULATION
LEVEL SUN RES FOR CT USE (UL) SEQUENTIAL
FOOTAGE MARK

•	2 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

*	Sizes smaller than 1/0 AWG do not include
“FOR CT USE”.

Options:

•	Other jacket options available upon request
•	STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610
•	100% insulation level

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

Applications:

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
•	For use in wet or dry locations when installed in
accordance with NEC
•	For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

•	5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Chlorinated Polyethylene (CPE)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) COMPACT CU

CATALOG
NUMBER

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL
INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
AMPACITY
DIAMETER
JACKET
SIZE DIAMETER
CONDUIT
INCHES
THICKNESS
COPPER WEIGHT
DIAMETER
WEIGHT
(AWG/
CONDUIT UNDERGROUND TRAY SIZING (4)
kcmil) INCHES
MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1)
DUCT (2)
(3) (INCHES)

15 kV ¥ , UL TYPE MV-105, 133% INS. LEVEL, 220 MILS
17131.130200*
17131.130100*
17131.135100*
17131.135200*
17131.135300*
17131.135400*
17131.136000*
17131.136200*
17131.136500*
17131.137000*
17131.637500*

2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

0.27
0.31
0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

0.710
0.745
0.780
0.820
0.865
0.920
0.970
1.070
1.190
1.370
1.520

0.800
0.830
0.865
0.905
0.955
1.005
1.060
1.155
1.275
1.460
1.610

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110

2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79

0.99
1.02
1.06
1.10
1.14
1.21
1.25
1.35
1.47
1.65
1.86

25.14
25.91
26.92
27.94
28.95
30.73
31.75
34.29
37.34
41.91
47.24

655
730
820
933
1072
1248
1402
1778
2325
3250
4209

975
1086
1220
1388
1595
1857
2086
2646
3460
4836
6263

276
332
403
492
603
743
866
1184
1657
2445
3228

411
494
600
732
897
1105
1289
1761
2466
3638
4803

165
190
215
255
290
330
365
440
535
655
755

165
185
215
245
275
315
345
415
500
610
690

220
250
290
335
370
460
575
745
890

3
3.5
3.5
3.5
3.5
3.5
4
5
5
6
6

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F);
the ampacities are based on 75% of the values per Table 310.60(C)(69). For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values shown above.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
¥100% insulation level is available upon request
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6380
March, 2012

GenFree Uniblend
®

®

EPR/Copper Tape Shield/LSZH, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105/ST1, 133% Ins. Level, 220 Mils
Product Construction:
Conductor:

•	2 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Overall Jacket:

•	Lead-free, moisture- and sunlight-resistant
Low-Smoke, Zero-Halogen Polyolefin (LSZH)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) COMPACT CU
GENFREE® UNIBLEND ® LSZH JKT (INSULATION
THICKNESS) EPR TYPE MV-105/ST1 (VOLTAGE)
KV% INSULATION LEVEL SUN RES FOR CT USE
(UL) SEQUENTIAL FOOTAGE MARK
	 * Sizes smaller than 1/0 AWG do not include
“FOR CT USE”.

Options:

• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610
•	100% insulation level

CATALOG
NUMBER

Applications:

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
• For use in wet or dry locations when installed in
accordance with NEC
• For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	ICEA T-33-655
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	UL 1685 Vertical Flame and Smoke Release Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Features:

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL
COND. CONDUCTOR
SIZE DIAMETER
(AWG/
kcmil) INCHES

INSULATION
NOMINAL
NOMINAL CABLE
AMPACITY
DIAMETER
JACKET
CONDUIT
INCHES
THICKNESS
COPPER WEIGHT CONDUIT UNDERGROUND TRAY SIZING
DIAMETER
WEIGHT
(4)
MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1) DUCT (2)
(3) (INCHES)

2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

0.710
0.745
0.780
0.820
0.865
0.920
0.970
1.070
1.190
1.370
1.520

15 kV ¥ , UL TYPE MV-105/ST1, 133% INS. LEVEL, 220 MILS
17231.130200
17231.130100*
17231.135100*
17231.135200
17231.135300*
17231.135400
17231.136000*
17231.136200
17231.136500
17231.137000
17231.137500*

0.27
0.31
0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

0.800
0.830
0.865
0.905
0.955
1.005
1.060
1.155
1.275
1.460
1.610

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110

2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79

0.99
1.02
1.06
1.10
1.14
1.21
1.25
1.35
1.47
1.65
1.86

25.14
25.91
26.92
27.94
28.95
30.73
31.75
34.29
37.34
41.91
47.24

658
733
825
938
1078
1261
1407
1783
2331
3234
4219

979
1090
1228
1396
1604
1876
2093
2653
3468
4812
6278

276
332
403
492
603
743
866
1184
1657
2445
3228

411
494
600
732
897
1105
1289
1761
2466
3638
4803

165
190
215
255
290
330
365
440
535
655
755

165
185
215
245
275
315
345
415
500
610
690

220
250
290
335
370
460
575
745
890

3
3.5
3.5
3.5
3.5
3.5
4
5
5
6
6

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F);
the ampacities are based on 75% of the values per Table 310.60(C)(69). For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values shown above.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
¥100% insulation level is available upon request
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6400

January, 2011

Copper Wire Shield

TRXLPE/Copper Wire Shield/PVC, Medium-Voltage Power
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils
Features:

Product Construction:
Conductor:

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) CU (INSULATION
THICKNESS) TRXLPE TYPE MV-105 (VOLTAGE)
KV% INSULATION LEVEL SUN RES (UL)
SEQUENTIAL FOOTAGE MARK

• 2 AWG thru 1000 kcmil annealed bare copper,
Class B compressed strand in accordance with
ASTM B3 and B8

Extruded Strand Shield (ESS):

• Extruded thermoset semi-conducting stresscontrol layer over conductor

Options:

•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC and in accordance with UL 1685
(70,000 BTU/hr)
•	STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610

Insulation:

• Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Extruded Insulation Shield (EIS):

• Thermoset semi-conducting polymeric layer free
stripping from insulation

Applications:

•	For use in wet or dry locations when installed in
accordance with NEC
•	For use in aerial, conduit, open tray and
underground duct installations where cost
effectiveness is a factor
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Metallic Shield:

• A concentric serve of 24 AWG annealed solid
bare copper wires over which shall be applied a
lapped non-metallic tape

Jacket:

• Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC)

CATALOG
NUMBER

•	Rated at 105˚C
•	Triple tandem extrusion of the strand shield,
insulation and insulation shield provides a
virtually perfect cable core
•	Excellent resistance to electro-chemical treeing,
heat, moisture and a wide variety of industrial
chemicals
•	PVC jacket provides mechanical protection of
the shielding system during installation as well as
protection from many industrial chemicals
•	Sunlight-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL 1072
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable

Packaging:

•	Material cut to length and shipped on nonreturnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and triplexing

NOMINAL INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
AMPACITY
JACKET
SIZE DIAMETER DIAMETER
CONDUIT
INCHES
THICKNESS
COPPER WEIGHT CONDUIT IN UNDERGROUND TRAY SIZING
DIAMETER
WEIGHT
(AWG/
(4)
kcmil) INCHES
MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km
AIR (1)
DUCT (2)
(3) (INCHES)

15 kV ¥ , UL TYPE MV-105, 133% INS. LEVEL, 220 MILS
17245.010200*
17245.010100*
17245.015100*
17245.015200*
17245.015400*
17245.016000*
17245.016200*
17245.016500*
17245.017000*
17245.017500*

2
1
1/0
2/0
4/0
250
350
500
750
1000

0.29
0.33
0.37
0.41
0.52
0.56
0.67
0.80
0.97
1.12

0.725
0.765
0.805
0.850
0.955
1.010
1.115
1.240
1.430
1.575

0.815
0.855
0.895
0.935
1.045
1.100
1.200
1.330
1.520
1.670

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110

2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79

1.05
1.09
1.13
1.18
1.29
1.34
1.45
1.57
1.82
1.97

26.67
27.68
28.27
29.97
32.76
34.03
36.83
39.87
46.23
50.04

600
671
761
871
1179
1327
1700
2236
3225
4090

893
998
1132
1296
1754
1974
2529
3327
4798
6086

221
274
342
427
672
791
1105
1568
2344
3114

329
408
509
635
1000
1177
1644
2333
3488
4634

165
190
215
255
330
365
440
535
655
755

165
185
215
245
315
345
415
500
610
690

220
250
335
370
460
575
745
890

3.5
3.5
3.5
4
4
5
5
5
6
6

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F);
the ampacities are based on 75% of the values per Table 310.60(C)(69). For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values shown above.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
¥100% insulation level is available upon request
Note: The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6450

March, 2012

Uniblend

®

EPR/Copper Tape Shield with Overall PVC Jacket, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils, Three Conductor
Product Construction:
Conductor:

•	2 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Options:

• Other jacket options available upon request
• Jacketed singles
• UniShield® singles
• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610
• 3 bare copper ground wires
• Covered ground wires

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

Applications:

• 5 mil annealed copper tape with an
overlap of 25%

• Suited for use in a broad range of commercial,
industrial and utility applications, where reliability
is the major concern, space is limited and ease of
installation is critical
• In wet or dry locations when installed in
accordance with NEC
• In aerial, direct burial, conduit, open tray and
underground duct installations

Grounding Conductor:

•	1 bare grounding conductor may be in contact
with metallic shielding tape

Overall Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
3/C SIZE (AWG OR KCMIL) COMPACT CU
UNIBLEND ® PVC JKT (INSULATION THICKNESS)
EPR TYPE MV-105 (VOLTAGE) KV% INSULATION
LEVEL DIR BUR SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK

CATALOG
NUMBER

Features:

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (70,000 BTU/hr)
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• IEEE 1202 (70,000 BTU/hr)/CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and plexing

NOMINAL
INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
AMPACITY
DIAMETER GROUND OVERALL JKT.
SIZE DIAMETER
INCHES
THICKNESS
COPPER
WEIGHT
DIAMETER
WEIGHT
(AWG/
WIRE
CONDUIT UNDERGROUND
kcmil) INCHES
MIN. MAX. (AWG) INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1)
DUCT (2)
TRAY (3)

15 kV ¥ , UL TYPE MV-105, 133% INS. LEVEL, 220 MILS, THREE CONDUCTOR
15493.440200*
15493.445100*
15493.445200*
15493.445400*
15493.446000*
15493.446200*
15493.446500*
15493.447000*
15493.447500*

2
1/0
2/0
4/0
250
350
500
750
1000

0.27
0.34
0.38
0.48
0.53
0.62
0.74
0.91
1.06

0.710
0.780
0.820
0.920
0.970
1.070
1.190
1.370
1.520

0.800
0.865
0.905
1.005
1.060
1.155
1.275
1.460
1.610

6
4
4
3
2
2
1
1/0
2/0

0.110
0.110
0.110
0.110
0.110
0.110
0.140
0.140
0.140

2.79
2.79
2.79
2.79
2.79
2.79
3.56
3.56
3.56

2.04 51.82
2.20 55.88
2.30 58.42
2.52 64.01
2.66 67.56
2.94 74.68
3.21 81.53
3.61 91.69
3.99 101.35

2226
2811
3163
4203
4775
6182
7686
10978
13983

3313
4183
4707
6255
7106
9200
11438
16337
20810

913
1343
1609
2398
2812
3766
5244
7682
10124

1358
1998
2394
3567
4184
5604
7803
11431
15064

165
215
245
320
350
430
525
635
725

160
210
235
305
335
400
485
585
660

185
240
275
360
400
490
600
745
860

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(75) of the NEC for three conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an ambient air
temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(79) of the NEC for three conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature of 105˚C (221˚F)
and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) The ampacities are based on three conductor Type MV-105 in an uncovered tray in accordance with Section 392.80(B)(1) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are per
Table 310.60(C)(71). For cable tray with unventilated covers for more than 6 feet, the ampacities shall not exceed 95% of the values in NEC Table 310.60(C)(75).
¥100% insulation level is available upon request
Note: a) All sizes are “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6455

March, 2012

Uniblend LF EPR/Copper Tape Shield with Overall PVC Jacket
®

Medium-Voltage Power, Shielded, 15 kV, UL Type MV-105, 133% Ins.
Level, 220 Mils, Three Conductor
Features:

Product Construction:
Conductor:

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/
YR OF MANUFACTURE) LIGHTNING BOLT
SYMBOL 3/C SIZE (AWG OR KCMIL) COMPACT
CU UNIBLEND ® LF PVC JKT (INSULATION
THICKNESS) EPR TYPE MV-105 (VOLTAGE) KV%
INSULATION LEVEL DIR BUR SUN RES FOR CT
USE (UL) SEQUENTIAL FOOTAGE MARK

•	2 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Options:

Insulation:

• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610
• 3 bare copper ground wires
• Covered ground wires

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Grounding Conductor:

•	1 bare grounding conductor may be in contact
with metallic shielding tape

Applications:

• Suited for use in a broad range of commercial,
industrial and utility applications, where reliability
is the major concern, space is limited and ease of
installation is critical
• In wet or dry locations when installed in
accordance with NEC
• In aerial, direct burial, conduit, open tray and
underground duct installations

Overall Jacket:

•	Low-friction, lead-free, flame-retardant, moistureand sunlight-resistant Polyvinyl Chloride (PVC)

CATALOG
NUMBER

•	Rated at 105˚C
•	Lower coefficient of friction
for ease of installation
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (70,000 BTU/hr)
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• IEEE 1202 (70,000 BTU/hr)/CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and plexing

NOMINAL
INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
AMPACITY
DIAMETER GROUND OVERALL JKT.
SIZE DIAMETER
INCHES
THICKNESS
COPPER WEIGHT CONDUIT UNDERGROUND
DIAMETER
WEIGHT
(AWG/
WIRE
kcmil) INCHES
MIN. MAX. (AWG) INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1) DUCT (2)
TRAY (3)

15 kV ¥ , UL TYPE MV-105, 133% INS. LEVEL, 220 MILS, THREE CONDUCTOR
15493.440205
15493.445105
15493.445205
15493.445405
15493.446005*
15493.446205
15493.446505
15493.447005*
15493.447505*

2
1/0
2/0
4/0
250
350
500
750
1000

0.27
0.34
0.38
0.48
0.53
0.62
0.74
0.91
1.06

0.710
0.780
0.820
0.920
0.970
1.070
1.190
1.370
1.520

0.800
0.865
0.905
1.005
1.060
1.155
1.275
1.460
1.610

6
4
4
3
2
2
1
1/0
2/0

0.110
0.110
0.110
0.110
0.110
0.110
0.140
0.140
0.140

2.79
2.79
2.79
2.79
2.79
2.79
3.56
3.56
3.56

2.04 51.82
2.20 55.88
2.30 58.42
2.52 64.01
2.66 67.56
2.94 74.68
3.21 81.53
3.61 91.69
3.99 101.35

2226
2811
3163
4203
4775
6182
7686
10978
13983

3313
4183
4707
6255
7106
9200
11438
16337
20810

913
1343
1609
2398
2812
3766
5244
7682
10124

1358
1998
2394
3567
4184
5604
7803
11431
15064

165
215
245
320
350
430
525
635
725

160
210
235
305
335
400
485
585
660

185
240
275
360
400
490
600
745
860

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(75) of the NEC for three conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an ambient air
temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(79) of the NEC for three conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature of 105˚C (221˚F)
and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) The ampacities are based on three conductor Type MV-105 cables in single layer in an uncovered tray with maintained spacing of not less than one cable diameter between cables, in accordance with
Section 392.80(B)(1) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are per Table 310.60(C)(71). For cable tray with unventilated covers for more than 6 feet, the ampacities shall not
exceed 95% of the values in NEC Table 310.60(C)(75).
¥100% insulation level is available upon request
Note: a) All sizes are “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6475

March, 2012

Uniblend

®

EPR/Copper Tape Shield with Overall CPE Jacket, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils, Three Conductor
Product Construction:
Conductor:

•	2 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Options:

• Other jacket options available upon request
• Jacketed singles
• UniShield® singles
• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610
• 3 bare copper ground wires
• Covered ground wires

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

Applications:

• 5 mil annealed copper tape with an
overlap of 25%

• Suited for use in a broad range of commercial,
industrial and utility applications, where reliability
is the major concern, space is limited and ease of
installation is critical
• In wet or dry locations when installed in
accordance with NEC
• In aerial, direct burial, conduit, open tray and
underground duct installations

Grounding Conductor:

•	1 bare grounding conductor may be in contact
with metallic shielding tape

Overall Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Chlorinated Polyethylene (CPE)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
3/C SIZE (AWG OR KCMIL) COMPACT CU
UNIBLEND ® CPE JKT (INSULATION THICKNESS)
EPR TYPE MV-105 (VOLTAGE) KV% INSULATION
LEVEL DIR BUR SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK

CATALOG
NUMBER

Features:

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (70,000 BTU/hr)
•	OSHA Acceptable
Optional Flame Tests:
• IEEE 1202 (70,000 BTU/hr)/CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and plexing

NOMINAL INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
AMPACITY
DIAMETER GROUND OVERALL JKT.
SIZE DIAMETER
INCHES
COPPER WEIGHT CONDUIT UNDERGROUND
DIAMETER
WEIGHT
(AWG/
WIRE THICKNESS
kcmil) INCHES
MIN. MAX. (AWG) INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1)
DUCT (2)
TRAY (3)

15 kV ¥ , UL TYPE MV-105, 133% INS. LEVEL, 220 MILS, THREE CONDUCTOR
15593.440200*
15593.445100*
15593.445200*
15593.445400*
15593.446000*
15593.446200*
15593.446500*
15593.447000*
15593.447500*

2
1/0
2/0
4/0
250
350
500
750
1000

0.27
0.34
0.38
0.48
0.53
0.62
0.74
0.91
1.06

0.710
0.780
0.820
0.920
0.970
1.070
1.190
1.370
1.520

0.800
0.865
0.905
1.005
1.060
1.155
1.275
1.460
1.610

6
4
4
3
2
2
1
1/0
2/0

0.110
0.110
0.110
0.110
0.110
0.110
0.140
0.140
0.140

2.79
2.79
2.79
2.79
2.79
2.79
3.56
3.56
3.56

2.04 51.82
2.20 55.88
2.30 58.42
2.52 64.01
2.66 67.56
2.94 74.68
3.21 81.53
3.61 91.69
3.99 101.35

2226
2811
3163
4203
4775
6182
7686
10978
13983

3313
4183
4707
6255
7106
9200
11438
16337
20810

913
1343
1609
2398
2812
3766
5244
7682
10124

1358
1998
2394
3567
4184
5604
7803
11431
15064

165
215
245
320
350
430
525
635
725

160
210
235
305
335
400
485
585
660

185
240
275
360
400
490
600
745
860

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(75) of the NEC for three conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an ambient air
temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(79) of the NEC for three conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature of 105˚C (221˚F)
and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) The ampacities are based on three conductor Type MV-105 in an uncovered tray in accordance with Section 392.80(B)(1) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are per
Table 310.60(C)(71). For cable tray with unventilated covers for more than 6 feet, the ampacities shall not exceed 95% of the values in NEC Table 310.60(C)(75).
¥100% insulation level is available upon request
Note: a) Sizes smaller than 4/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6480

March, 2012

GenFree Uniblend
®

®

EPR/Copper Tape Shield with Overall LSZH Jacket, Medium-Voltage Power, Shielded
15 kV, UL Type MV-105, 133% Ins. Level, 220 Mils, Three Conductor
Features:

Product Construction:
Conductor:

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
3/C SIZE (AWG OR KCMIL) COMPACT CU
GENFREE® UNIBLEND ® LSZH JKT (INSULATION
THICKNESS) EPR TYPE MV-105 (VOLTAGE) KV%
INSULATION LEVEL DIR BUR SUN RES FOR CT
USE (UL) SEQUENTIAL FOOTAGE MARK

•	2 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Options:

Insulation:

• STRANDFILL® – blocked conductor. Tested in
accordance with ICEA T-31-610
• 3 bare copper ground wires
• Covered ground wires

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Applications:

•	Suited for use in a broad range of commercial,
industrial and utility applications, where reliability
is the major concern, space is limited and ease of
installation is critical
•	In wet or dry locations when installed in
accordance with NEC
•	In aerial, direct burial, conduit, open tray and
underground duct installations

Metallic Shield:

•	5 mil annealed copper tape with an
overlap of 25%

Grounding Conductor:

•	1 bare grounding conductor may be in contact
with metallic shielding tape

Overall Jacket:

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	ICEA T-33-655
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (70,000 BTU/hr)
•	OSHA Acceptable
Optional Flame Tests:
• IEEE 1202 (70,000 BTU/hr)/CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and plexing

•	Lead-free, moisture- and sunlight-resistant
Low-Smoke, Zero-Halogen Polyolefin (LSZH)

CATALOG
NUMBER

NOMINAL INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
AMPACITY
DIAMETER GROUND OVERALL JKT.
SIZE DIAMETER
INCHES
COPPER WEIGHT CONDUIT UNDERGROUND
DIAMETER
WEIGHT
(AWG/
WIRE THICKNESS
kcmil) INCHES
MIN. MAX. (AWG) INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1)
DUCT (2)
TRAY (3)

15 kV ¥ , UL TYPE MV-105, 133% INS. LEVEL, 220 MILS, THREE CONDUCTOR
15793.440200*
15793.445100*
15793.445200*
15793.445400*
15793.446000*
15793.446200*
15793.446500*
15793.447000*
15793.447500*

2
1/0
2/0
4/0
250
350
500
750
1000

0.27
0.34
0.38
0.48
0.53
0.62
0.74
0.91
1.06

0.710
0.780
0.820
0.920
0.970
1.070
1.190
1.370
1.520

0.800
0.865
0.905
1.005
1.060
1.155
1.275
1.460
1.610

6
4
4
3
2
2
1
1/0
2/0

0.110
0.110
0.110
0.110
0.110
0.110
0.140
0.140
0.140

2.79
2.79
2.79
2.79
2.79
2.79
3.56
3.56
3.56

2.04 51.82
2.20 55.88
2.30 58.42
2.52 64.01
2.66 67.56
2.94 74.68
3.21 81.53
3.61 91.69
3.99 101.35

2226
2811
3163
4203
4775
6182
7686
10978
13983

3313
4183
4707
6255
7106
9200
11438
16337
20810

913
1343
1609
2398
2812
3766
5244
7682
10124

1358
1998
2394
3567
4184
5604
7803
11431
15064

165
215
245
320
350
430
525
635
725

160
210
235
305
335
400
485
585
660

185
240
275
360
400
490
600
745
860

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(75) of the NEC for three conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an ambient air
temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(79) of the NEC for three conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature of 105˚C (221˚F)
and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) The ampacities are based on three conductor Type MV-105 in an uncovered tray in accordance with Section 392.80(B)(1) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are per
Table 310.60(C)(71). For cable tray with unventilated covers for more than 6 feet, the ampacities shall not exceed 95% of the values in NEC Table 310.60(C)(75).
¥100% insulation level is available upon request
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6500

June, 2013

UniShield

®

EPR/Copper Wire Shield/CPE, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils
Product Construction:
Conductor:

•	1/0 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with black conducting shield
layers

Composite Insulation Shield
and Jacket:

•	Six corrugated copper drain wires embedded in
composite layers of semi-conducting thermoset
copolymer and semi-conducting black flameretardant Chlorinated Polyethylene (CPE)

Print:

•	GENERAL CABLE (PLANT OF MFG) (MO/
YR OF MANUFACTURE) LIGHTNING BOLT
SYMBOL 1/C SIZE (AWG OR KCMIL) COMPACT
CU UNISHIELD ® (INSULATION THICKNESS)
EPR DRTP SEMI-CON CPE JKT TYPE MV-105
(VOLTAGE) KV% INSULATION LEVEL SUN RES
FOR CT USE (UL) SEQUENTIAL FOOTAGE MARK
®

*S
 izes smaller than 1/0 AWG do not include
“FOR CT USE”.

Options:

•	25 kV 100% insulation level
•	35 kV 133% insulation level

Applications:

•	Installed in a broad range of commercial, industrial
and utility projects such as pulp and paper
mills, petrochemical plants, steel mills, textile
mills, water and sewage treatment facilities,
environmental protection systems, railroads,
mines and fossil fuel utility generating stations

CATALOG
NUMBER

NOMINAL
COND. CONDUCTOR
SIZE DIAMETER
(AWG/
kcmil) INCHES

INSULATION
DIAMETER
INCHES
MIN. MAX.

Applications (cont’d.):

•	Suitable for use in wet or dry locations when
installed in accordance with NEC
•	For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Features:

•	Rated at 105˚C
•	Reduced conductor size and shield system
provide the smallest premium medium-voltage
shielded power cable with full insulation
•	Smaller outside dimensions reduce the size of
duct needed or increase the ampacity
per duct
•	All features contribute to faster and
easier installation
•	Superior cold bend and cold impact
performance
•	Stable and constant shield short
circuit performance
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low dielectric loss
•	Low moisture absorption
•	Electrical stability under stress
•	Chemical-resistant
•	Sunlight-resistant
•	Meets cold bend test at -55˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on nonreturnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and triplexing
	 NOTE: Due to the semi-conducting properties of the

cable jacket, multi-point grounding is recommended for
all UniShield® installations.

DRAIN
NOMINAL CABLE
AMPACITY
WIRE
CONDUlT
COPPER WEIGHT CONDUIT IN UNDERGROUND DIRECT SIZING
DIAMETER
WEIGHT
SIZE
(4)
(AWG) INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km AIR (1)
DUCT (2)
BURIAL (3) (INCHES)

25 kV ¥ & 35 kV ¥¥ , UL TYPE MV-105, 133%/100% INS. LEVEL, 345 MILS
19261.685100*
19261.685200*
19261.685300*
19261.685400*
19261.686000*
19261.686200*
19261.686500*
19261.687000*
19261.687500*

1/0
2/0
3/0
4/0
250
350
500
750
1000

0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

1.020
1.060
1.105
1.160
1.210
1.310
1.430
1.610
1.760

1.120
1.160
1.205
1.260
1.315
1.410
1.530
1.710
1.865

17
17
17
17
16
16
16
16
16

1.29
1.36
1.41
1.43
1.51
1.60
1.74
1.95
2.11

32.77
34.54
35.81
36.32
38.35
40.64
44.20
49.78
53.59

1014
1163
1310
1442
1645
2024
2608
3596
4513

1509
1731
1949
2146
2448
3012
3881
5351
6715

367
452
559
694
824
1133
1596
2368
3138

546
672
832
1033
1226
1685
2374
3523
4669

215
255
290
330
365
440
535
655
755

215
245
275
315
345
415
500
610
690

295
335
380
435
475
575
700
865
1005

4
5
5
5
5
5
6
6
8

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are in accordance with Table 310.60(C)(81) of the NEC for single insulated copper conductors directly buried in earth, based on a conductor temperature of 105˚C (221˚F) and an ambient earth
temperature of 20˚C (68˚F), arrangement per Figure 310.60 Detail 9, 100% load factor, and earth thermal resistance (rho) of 90.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
¥100% insulation level is available upon request
¥¥133% insulation level is available upon request
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all UniShield® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6550
March, 2012

Uniblend

®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils
Features:

Product Construction:
Conductor:

Print (cont’d.):

	 UNIBLEND ® PVC JKT (INSULATION THICKNESS)
EPR TYPE MV-105 (VOLTAGE) KV% INSULATION
LEVEL SUN RES FOR CT USE (UL) SEQUENTIAL
FOOTAGE MARK

•	1/0 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

*S
 izes smaller than 1/0 AWG do not include
“FOR CT USE”.

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Options:

Insulation:

• Other jacket options available upon request
• STRANDFILL® - blocked conductor. Tested in
accordance with ICEA T-31-610
•	25 kV 100% insulation level
•	35 kV 133% insulation level

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

Applications:

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) COMPACT CU

CATALOG
NUMBER

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
• For use in wet or dry locations when installed in
accordance with NEC
• For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
AMPACITY
JACKET
SIZE DIAMETER DIAMETER
CONDUIT
INCHES
THICKNESS
COPPER WEIGHT CONDUIT UNDERGROUND DIRECT SIZING
DIAMETER
WEIGHT
(AWG/
(4)
kcmil) INCHES
MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1) DUCT (2) BURIAL (3) (INCHES)

25 kV ¥ AND 35 kV ¥¥ , UL TYPE MV-105, 133%/100% INS. LEVELS, 345 MILS
17061.135100*
17061.135200*
17061.135300*
17061.135400*
17061.136000*
17061.136200*
17061.136500*
17061.137000*
17061.137500*

1/0
2/0
3/0
4/0
250
350
500
750
1000

0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

1.020
1.060
1.105
1.160
1.210
1.310
1.430
1.610
1.760

1.120
1.160
1.205
1.260
1.315
1.410
1.530
1.710
1.865

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110

2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79

1.31
1.35
1.40
1.45
1.51
1.60
1.72
1.96
2.10

33.27
34.29
35.56
36.83
38.35
40.64
45.21
49.78
53.59

1090
1211
1360
1547
1712
2108
2650
3733
4651

1622
1802
2024
2302
2547
3137
4141
5555
6921

425
514
625
765
888
1206
1679
2467
3250

633
765
930
1138
1322
1794
2498
3670
4836

215
255
290
330
365
440
535
655
755

215
245
275
315
345
415
500
610
690

295
335
380
435
475
575
700
865
1005

5
5
5
5
5
5
6
6
8

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are in accordance with Table 310.60(C)(81) of the NEC for single insulated copper conductors directly buried in earth, based on a conductor temperature of 105˚C (221˚F) and an ambient earth
temperature of 20˚C (68˚F), arrangement per Figure 310.60 Detail 9, 100% load factor, and earth thermal resistance (rho) of 90.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio should be checked for individual installations.
¥100% insulation level is available upon request
¥¥133% insulation level is available upon request
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6555
March, 2012

Uniblend LF
®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils
Product Construction:
Conductor:

•	1/0 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Low-friction, lead-free, flame-retardant, moistureand sunlight-resistant Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/
YR OF MANUFACTURE) LIGHTNING BOLT
SYMBOL 1/C SIZE (AWG OR KCMIL) COMPACT
CU UNIBLEND ® LF PVC JKT (INSULATION
THICKNESS) EPR TYPE MV-105 (VOLTAGE) KV%
INSULATION LEVEL SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK

Options:

• STRANDFILL® - blocked conductor. Tested in
accordance with ICEA T-31-610
•	25 kV 100% insulation level
•	35 kV 133% insulation level

CATALOG
NUMBER

Compliances:

Applications:

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
• For use in wet or dry locations when installed in
accordance with NEC
• For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Features:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 UL Flame Exposure Test
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Rated at 105˚C
•	Lower coefficient of friction for ease of
installation
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL INSULATION NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
AMPACITY
JACKET
SIZE DIAMETER DIAMETER
CONDUIT
INCHES
THICKNESS
COPPER WEIGHT CONDUIT UNDERGROUND DIRECT SIZING
DIAMETER
WEIGHT
(AWG/
(4)
kcmil) INCHES MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1) DUCT (2) BURIAL (3) (INCHES)

25 kV ¥ AND 35 kV ¥¥ , UL TYPE MV-105, 133%/100% INS. LEVELS, 345 MILS
17061.135105
17061.135205*
17061.135305*
17061.135405
17061.136005*
17061.136205
17061.136505
17061.137005*
17061.137505*

1/0
2/0
3/0
4/0
250
350
500
750
1000

0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

1.020
1.060
1.105
1.160
1.210
1.310
1.430
1.610
1.760

1.120
1.160
1.205
1.260
1.315
1.410
1.530
1.710
1.865

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110

2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79

1.31
1.35
1.40
1.45
1.51
1.60
1.72
1.96
2.10

33.27
34.29
35.56
36.83
38.35
40.64
45.21
49.78
53.59

1090
1211
1360
1547
1712
2108
2650
3733
4651

1622
1802
2024
2302
2547
3137
4141
5555
6921

425
514
625
765
888
1206
1679
2467
3250

633
765
930
1138
1322
1794
2498
3670
4836

215
255
290
330
365
440
535
655
755

215
245
275
315
345
415
500
610
690

295
335
380
435
475
575
700
865
1005

5
5
5
5
5
5
6
6
8

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are in accordance with Table 310.60(C)(81) of the NEC for single insulated copper conductors directly buried in earth, based on a conductor temperature of 105˚C (221˚F) and an ambient earth
temperature of 20˚C (68˚F), arrangement per Figure 310.60 Detail 9, 100% load factor, and earth thermal resistance (rho) of 90.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio should be checked for individual installations.
¥100% insulation level is available upon request
¥¥133% insulation level is available upon request
Note: The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6560

March, 2012

Aluminum Uniblend LF
®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils
Features:

Product Construction:
Conductor:

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/
YR OF MANUFACTURE) LIGHTNING BOLT
SYMBOL 1/C SIZE (AWG OR KCMIL) COMPACT
AL UNIBLEND ® LF PVC JKT (INSULATION
THICKNESS) EPR TYPE MV-105 (VOLTAGE) KV%
INSULATION LEVEL SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK

•	1/0 AWG thru 1000 kcmil 1350 aluminum
compact Class B STRANDFILL® blocked
conductor

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Options:

Insulation:

•	25 kV 100% insulation level
•	35 kV 133% insulation level

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Applications:

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Low-friction, lead-free, flame-retardant, moistureand sunlight-resistant Polyvinyl Chloride (PVC)

CATALOG
NUMBER

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
• For use in wet or dry locations when installed in
accordance with NEC
• For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

•	Rated at 105˚C
•	Lower coefficient of friction
for ease of installation
•	Meets longitudinal water penetration resistance
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 UL Flame Exposure Test
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL INSULATION NOMINAL
NOMINAL CABLE
AMPACITY
COND. CONDUCTOR DIAMETER
CONDUIT
JACKET
SIZE DIAMETER
DIRECT SIZING
WEIGHT
INCHES
THICKNESS DIAMETER
ALUMINUM WEIGHT COPPER WEIGHT CONDUIT
(AWG/
IN AIR UNDERGROUND BURIAL (4)
kcmil) INCHES MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km LBS/1000 FT kg/km (1)
DUCT (2)
(3) (INCHES)

25 kV ¥ AND 35 kV ¥¥ , UL TYPE MV-105, 133%/100% INS. LEVEL, 345 MILS
17061.135108*
17061.135208*
17061.135308*
17061.135408*
17061.136008*
17061.136208*
17061.136508*
17061.137008*
17061.137508*

1/0
2/0
3/0
4/0
250
350
500
750
1000

0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

1.020
1.060
1.105
1.160
1.210
1.310
1.430
1.610
1.760

1.120
1.160
1.205
1.260
1.315
1.410
1.530
1.710
1.865

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110

2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79

1.31
1.35
1.40
1.45
1.51
1.60
1.72
1.96
2.10

33.27
34.29
35.56
36.83
38.35
40.64
45.21
49.78
53.59

863
925
1000
1093
1174
1356
1707
2120
2500

1285
1377
1488
1626
1747
2018
2540
3155
3720

99
125
158
199
234
329
468
703
937

147
186
235
296
348
490
696
1046
1394

99
103
107
112
116
125
135
151
162

147
153
159
167
173
186
201
225
241

170
200
225
260
290
350
430
540
640

165
190
215
245
270
330
400
490
565

230
260
295
340
370
450
545
680
795

5
5
5
5
5
5
6
6
8

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 105°C (221°F) and
an ambient air temperature of 40°C (104°F).
(2) Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor
temperature of 105°C (221°F) and an ambient earth temperature of 20°C (68°F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are in accordance with Table 310.60(C)(82) of the NEC for single insulated aluminum conductors directly buried in earth, based on a conductor temperature of 105°C (221°F) and an ambient
earth temperature of 20°C (68°F), arrangement per Figure 310.60 Detail 9, 100% load factor, and earth thermal resistance (rho) of 90.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
¥100% insulation level is available upon request.
¥¥133% insulation level is available upon request.
Note: The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6575

March, 2012

Uniblend

®

EPR/Copper Tape Shield/CPE, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils
Product Construction:
Conductor:

•	1/0 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Chlorinated Polyethylene (CPE)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) COMPACT CU
UNIBLEND ® CPE JKT (INSULATION THICKNESS)
EPR TYPE MV-105 (VOLTAGE) KV% INSULATION
LEVEL SUN RES FOR CT USE (UL) SEQUENTIAL
FOOTAGE MARK
*S
 izes smaller than 1/0 AWG do not include
“FOR CT USE”.

Options:

• Other jacket options available upon request
• STRANDFILL® - blocked conductor. Tested in
accordance with ICEA T-31-610
•	25 kV 100% insulation level
•	35 kV 133% insulation level

CATALOG
NUMBER

NOMINAL INSULATION
COND. CONDUCTOR
SIZE DIAMETER DIAMETER
INCHES
(AWG/
kcmil) INCHES
MIN. MAX.

Applications:

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
• For use in wet or dry locations when installed in
accordance with NEC
• For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Features:

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL
NOMINAL CABLE
AMPACITY
JACKET
CONDUIT
THICKNESS
COPPER WEIGHT CONDUIT UNDERGROUND DIRECT SIZING
DIAMETER
WEIGHT
(4)
INCHES
INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1) DUCT (2) BURIAL (3) (INCHES)

25 kV ¥ AND 35 kV ¥¥ , UL TYPE MV-105, 133%/100% INS. LEVELS, 345 MILS
17161.135100*
17161.135200*
17161.135300*
17161.135400*
17161.136000*
17161.136200*
17161.136500*
17161.137000*
17161.137500*

1/0
2/0
3/0
4/0
250
350
500
750
1000

0.340
0.380
0.430
0.480
0.530
0.630
0.740
0.910
1.060

1.020
1.060
1.105
1.160
1.210
1.310
1.430
1.610
1.760

1.120
1.160
1.205
1.260
1.315
1.410
1.530
1.710
1.865

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110

1.31
1.35
1.40
1.45
1.51
1.60
1.72
1.96
2.10

33.27
34.29
35.56
36.83
38.35
40.64
45.21
49.78
53.59

1066
1187
1335
1516
1681
2075
2650
3687
4603

1586
1766
1986
2256
2501
3088
3934
5486
6849

425
514
625
765
888
1206
1679
2467
3250

633
765
930
1138
1322
1794
2498
3670
4836

215
255
290
330
365
440
535
655
755

215
245
275
315
345
415
500
610
690

295
335
380
435
475
575
700
865
1005

5
5
5
5
5
5
6
6
8

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are in accordance with Table 310.60(C)(81) of the NEC for single insulated copper conductors directly buried in earth, based on a conductor temperature of 105˚C (221˚F) and an ambient earth
temperature of 20˚C (68˚F), arrangement per Figure 310.60 Detail 9, 100% load factor, and earth thermal resistance (rho) of 90.
(4) Based on nominal cable diameters, three single cables in the duct with no ground wire and a maximum of 40% fill. Jam ratio should be checked for individual installations.
¥100% insulation level is available upon request
¥¥133% insulation level is available upon request
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6580

March, 2012

GenFree Uniblend
®

®

EPR/Copper Tape Shield/LSZH, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105/ST1, 133%/100% Ins. Levels, 345 Mils
Features (cont’d.):

•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Product Construction:
Conductor:

	 INSULATION LEVEL SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK

•	1/0 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

	 * Sizes smaller than 1/0 AWG do not include
“FOR CT USE”.

Extruded Strand Shield (ESS):

Options:

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

• STRANDFILL® - blocked conductor. Tested in
accordance with ICEA T-31-610
•	25 kV 100% insulation level
•	35 kV 133% insulation level

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Applications:

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
• For use in wet or dry locations when installed in
accordance with NEC
• For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Overall Jacket:

•	Lead-free, moisture- and sunlight-resistant
Low-Smoke, Zero-Halogen Polyolefin (LSZH)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR OF
MANUFACTURE) LIGHTNING BOLT SYMBOL 1/C
SIZE (AWG OR KCMIL) COMPACT CU GENFREE®
UNIBLEND® LSZH JKT (INSULATION THICKNESS)
EPR TYPE MV-105/ST1 (VOLTAGE) KV%

CATALOG
NUMBER

Compliances:

Print (cont’d.):

Features:

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Excellent flame resistance

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	ICEA T-33-655
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (Sizes 1/0 AWG and larger) UL Flame
Exposure Test
•	UL 1685 Vertical Flame and Smoke Release Test
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
AMPACITY
JACKET
SIZE DIAMETER DIAMETER
CONDUIT
INCHES
THICKNESS
COPPER WEIGHT CONDUIT UNDERGROUND DIRECT SIZING
DIAMETER
WEIGHT
(AWG/
(4)
kcmil) INCHES
MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1) DUCT (2) BURIAL (3) (INCHES)

25 kV ¥ AND 35 kV ¥¥ , UL TYPE MV-105/ST1, 133%/100% INS. LEVELS, 345 MILS
17261.135100*
17261.135200*
17261.135300*
17261.135400*
17261.136000*
17261.136200*
17261.136500*
17261.137000*
17261.137500*

1/0
2/0
3/0
4/0
250
350
500
750
1000

0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

1.020
1.060
1.105
1.160
1.210
1.310
1.430
1.610
1.760

1.120
1.160
1.205
1.260
1.315
1.410
1.530
1.710
1.865

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.110
0.110

2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79

1.31
1.35
1.40
1.45
1.51
1.60
1.72
1.96
2.10

33.27
34.29
35.56
36.83
38.35
40.64
45.21
49.78
53.59

1090
1211
1360
1547
1712
2108
2650
3733
4651

1622
1802
2024
2302
2547
3137
4141
5555
6921

425
514
625
765
888
1206
1679
2467
3250

633
765
930
1138
1322
1794
2498
3670
4836

215
255
290
330
365
440
535
655
755

215
245
275
315
345
415
500
610
690

295
335
380
435
475
575
700
865
1005

5
5
5
5
5
5
6
6
8

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are in accordance with Table 310.60(C)(81) of the NEC for single insulated copper conductors directly buried in earth, based on a conductor temperature of 105˚C (221˚F) and an ambient earth
temperature of 20˚C (68˚F), arrangement per Figure 310.60 Detail 9, 100% load factor, and earth thermal resistance (rho) of 90.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio should be checked for individual installations.
¥100% insulation level is available upon request
¥¥133% insulation level is available upon request
Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6600

March, 2012

Uniblend

®

EPR/Copper Tape Shield with Overall PVC Jacket, Medium-Voltage Power, Shielded
25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils, Three Conductor
Product Construction:
Conductor:

•	1/0 AWG thru 750 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stress
control layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with black conducting shield
layers

Extruded Insulation Shield (EIS):

• Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an overlap
of 25%

Grounding Conductor:

• 1 bare grounding conductor may be in contact
with metallic shielding tape

Overall Jacket:

• Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
3/C SIZE (AWG OR KCMIL) COMPACT CU
UNIBLEND ® PVC JKT (INSULATION THICKNESS)
EPR TYPE MV-105 (VOLTAGE) KV% INSULATION
LEVEL DIR BUR SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK

Options:

• Other jacket options available upon request
• Jacketed singles
• UniShield® singles

CATALOG
NUMBER

Options (cont’d.):

• STRANDFILL® - blocked conductor. Tested in
accordance with ICEA T-31-610
• 3 bare copper ground wires
• Covered ground wires
•	25 kV 100% insulation level
•	35 kV 133% insulation level

Applications:

• Suited for use in a broad range of commercial,
industrial and utility applications, where reliability
is the major concern, space is limited and ease of
installation is critical
•	Suitable for use in wet or dry locations when
installed in accordance with NEC
•	In aerial, direct burial, conduit, open tray and
underground duct installations

Features:

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (70,000 BTU/hr)
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on nonreturnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and triplexing

NOMINAL INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
AMPACITY
OVERALL JKT.
SIZE DIAMETER DIAMETER
GROUND
INCHES
THICKNESS
COPPER WEIGHT CONDUIT IN UNDERGROUND DIRECT
DIAMETER
WEIGHT
(AWG/
WIRE
kcmil) INCHES
MIN. MAX. (AWG) INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km AIR (1)
DUCT (2) BURIAL (3)

25 kV ¥ AND 35 kV ¥¥ , UL TYPE MV-105, 133%/100% INS. LEVELS, 345 MILS, THREE CONDUCTOR
0.34
1.020 1.120
4
0.110 2.79 2.73 69.34
3672
5464
1410
2098
215
210
15493.485100* 1/0
0.38
1.060 1.160
4
0.110 2.79 2.81 71.37
4061
6042
1675
2492
245
235
15493.485200* 2/0
0.48
1.160 1.260
3
0.140 3.56 3.10 78.74
5313
7906
2465
3668
320
305
15493.485400* 4/0
0.53
1.210 1.315
2
0.140 3.56 3.21 81.53
6214
9246
2879
4284
350
335
15493.486000* 250
0.62
1.310 1.410
2
0.140 3.56 3.42 86.86
7138 10621
3834
5705
430
400
15493.486200* 350
0.74
1.430 1.530
1
0.140 3.56 3.68 93.47
9012 13410
5312
7904
525
485
15493.486500* 500
0.91
1.610 1.710 1/0
0.140 3.56 4.10 104.14 12030 17901
7750
11532
635
585
15493.487000* 750

255
290
375
410
495
590
720

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(75) of the NEC for three conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an ambient air
temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(79) of the NEC for three conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature of 105˚C (221˚F)
and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are in accordance with Table 310.60(C)(83) of the NEC for single insulated copper conductors directly buried in earth, based on a conductor temperature of 105˚C (221˚F) and an ambient earth
temperature of 20˚C (68˚F), arrangement per Figure 310.60 Detail 5, 100% load factor, and earth thermal resistance (rho) of 90.
¥100% insulation level is available upon request
¥¥133% insulation level is available upon request
Note: a) All sizes are “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6605

March, 2012

Uniblend LF EPR/Copper Tape Shield with Overall PVC Jacket
®

Medium-Voltage Power, Shielded, 25 kV and 35 kV, UL Type MV-105
133%/100% Ins. Levels, 345 Mils, Three Conductor
Features:

Product Construction:
Conductor:

•	1/0 AWG thru 750 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stress
control layer over conductor
•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with black conducting shield
layers

Extruded Insulation Shield (EIS):

• Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an overlap
of 25%

Grounding Conductor:

• 1 bare grounding conductor may be in contact
with metallic shielding tape
•	Low-friction, lead-free, flame-retardant, moistureand sunlight-resistant Polyvinyl Chloride (PVC)

CATALOG
NUMBER

•	GENERAL CABLE® (PLANT OF MFG) (MO/
YR OF MANUFACTURE) LIGHTNING BOLT
SYMBOL 3/C SIZE (AWG OR KCMIL) COMPACT
CU UNIBLEND ® LF PVC JKT (INSULATION
THICKNESS) EPR TYPE MV-105 (VOLTAGE) KV%
INSULATION LEVEL DIR BUR SUN RES FOR CT
USE (UL) SEQUENTIAL FOOTAGE MARK

Options:

Insulation:

Overall Jacket:

Print:

• STRANDFILL® - blocked conductor. Tested in
accordance with ICEA T-31-610
• 3 bare copper ground wires
• Covered ground wires
•	25 kV 100% insulation level
•	35 kV 133% insulation level

Applications:

• Suited for use in a broad range of commercial,
industrial and utility applications, where reliability
is the major concern, space is limited and ease of
installation is critical
•	Suitable for use in wet or dry locations when
installed in accordance with NEC
•	In aerial, direct burial, conduit, open tray and
underground duct installations

•	Rated at 105˚C
•	Lower coefficient of friction
for ease of installation
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	UL 1685 (70,000 BTU/hr)
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on nonreturnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than
1000 ft., lagging, pulling eyes, paralleling
and triplexing

NOMINAL INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
AMPACITY
OVERALL JKT.
SIZE DIAMETER DIAMETER
GROUND
INCHES
THICKNESS
COPPER WEIGHT CONDUIT IN UNDERGROUND DIRECT
DIAMETER
WEIGHT
(AWG/
WIRE
kcmil) INCHES
MIN. MAX. (AWG) INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km AIR (1)
DUCT (2) BURIAL (3)

25 kV ¥ AND 35 kV ¥¥ , UL TYPE MV-105, 133%/100% INS. LEVELS, 345 MILS, THREE CONDUCTOR
0.34
1.020 1.120
4
0.110 2.79 2.73 69.34
3672
5464
1410
2098
215
210
15493.485105* 1/0
0.38
1.060 1.160
4
0.110 2.79 2.81 71.37
4061
6042
1675
2492
245
235
15493.485205* 2/0
0.48
1.160 1.260
3
0.140 3.56 3.10 78.74
5313
7906
2465
3668
320
305
15493.485405* 4/0
0.53
1.210 1.315
2
0.140 3.56 3.21 81.53
6214
9246
2879
4284
350
335
15493.486005* 250
0.62
1.310 1.410
2
0.140 3.56 3.42 86.86
7138 10621
3834
5705
430
400
15493.486205* 350
0.74
1.430 1.530
1
0.140 3.56 3.68 93.47
9012 13410
5312
7904
525
485
15493.486505* 500
0.91
1.610 1.710 1/0 0.140 3.56 4.10 104.14 12030 17901
7750
11532
635
585
15493.487005* 750

255
290
375
410
495
590
720

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(75) of the NEC for three conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an ambient air
temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(79) of the NEC for three conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature of 105˚C (221˚F)
and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are in accordance with Table 310.60(C)(83) of the NEC for single insulated copper conductors directly buried in earth, based on a conductor temperature of 105˚C (221˚F) and an ambient earth
temperature of 20˚C (68˚F), arrangement per Figure 310.60 Detail 5, 100% load factor, and earth thermal resistance (rho) of 90.
¥100% insulation level is available upon request
¥¥133% insulation level is available upon request
Note: a) All sizes are “FOR CT USE”.
b) The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6650
November, 2013

Uniblend

®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
35 kV, UL Type MV-105, 133% Ins. Levels, 420 Mils
Product Construction:
Conductor:

•	1/0 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

Applications:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
• For use in wet or dry locations when installed in
accordance with NEC
• For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT SYMBOL
1/C SIZE (AWG OR KCMIL) COMPACT CU
UNIBLEND ® PVC JKT (INSULATION THICKNESS)
EPR TYPE MV-105 (VOLTAGE) KV% INSULATION
LEVEL SUN RES FOR CT USE (UL) SEQUENTIAL
FOOTAGE MARK

Features:

Options:

• Other jacket options available upon request
•	STRANDFILL® - blocked conductor. Tested in
accordance with ICEA T-31-610

CATALOG
NUMBER

•	Rated at 105˚C
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	Sizes 1/0 AWG and larger are listed and marked
“Sunlight-Resistant FOR CT USE” in accordance
with NEC
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
AMPACITY
JACKET
SIZE DIAMETER DIAMETER
CONDUIT
INCHES
THICKNESS
COPPER WEIGHT CONDUIT UNDERGROUND DIRECT SIZING
DIAMETER
WEIGHT
(AWG/
(4)
kcmil) INCHES
MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1) DUCT (2) BURIAL (3) (INCHES)

35 kV, UL TYPE MV-105, 133% INS. LEVELS, 420 MILS
17071.135100*
17071.135200*
17071.135300*
17071.135400*
17071.136000*
17071.136200*
17071.136500*
17071.137000*
17071.137500*

1/0
2/0
3/0
4/0
250
350
500
750
1000

0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

1.060
1.200
1.245
1.300
1.350
1.450
1.570
1.750
1.900

1.265
1.305
1.355
1.405
1.460
1.555
1.675
1.860
2.010

0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110

2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79

1.47
1.49
1.53
1.59
1.64
1.79
1.91
2.09
2.25

37.34
37.85
38.86
40.39
41.66
45.47
48.5
53.09
57.15

1253
1378
1532
1716
1888
2396
2986
3954
4885

1864
2050
2280
2553
2809
3565
4443
5884
7269

437
525
636
776
899
1217
1690
2477
3263

650
781
946
1155
1338
1811
2515
3685
4855

215
255
290
330
365
440
535
655
755

215
245
275
315
345
415
500
610
690

295
335
380
435
475
575
700
865
1005

5
5
5
5
6
6
6
6
8

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are in accordance with Table 310.60(C)(81) of the NEC for single insulated copper conductors directly buried in earth, based on a conductor temperature of 105˚C (221˚F) and an ambient earth
temperature of 20˚C (68˚F), arrangement per Figure 310.60 Detail 9, 100% load factor, and earth thermal resistance (rho) of 90.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio should be checked for individual installations.
Note: The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6655

November, 2013

Uniblend LF
®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
35 kV, UL Type MV-105, 133% Ins. Levels, 420 Mils
Features:

Product Construction:
Conductor:

Print:

•	1/0 AWG thru 1000 kcmil annealed bare copper
compact Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Options:

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Low-friction, lead-free, flame-retardant, moistureand sunlight-resistant Polyvinyl Chloride (PVC)

CATALOG
NUMBER

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT
SYMBOL 1/C SIZE (AWG OR KCMIL) COMPACT
CU UNIBLEND ® LF PVC JKT (INSULATION
THICKNESS) EPR TYPE MV-105 (VOLTAGE) KV%
INSULATION LEVEL SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK
•	STRANDFILL® - blocked conductor. Tested in
accordance with ICEA T-31-610

Applications:

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
• For use in wet or dry locations when installed in
accordance with NEC
• For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)

•	Rated at 105˚C
•	Lower coefficient of friction
for ease of installation
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

Compliances:

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL INSULATION
NOMINAL
COND. CONDUCTOR
NOMINAL CABLE
AMPACITY
JACKET
SIZE DIAMETER DIAMETER
CONDUIT
INCHES
THICKNESS
COPPER WEIGHT CONDUIT UNDERGROUND DIRECT SIZING
DIAMETER
WEIGHT
(AWG/
(4)
kcmil) INCHES MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km IN AIR (1) DUCT (2) BURIAL (3) (INCHES)

35 kV, UL TYPE MV-105, 133% INS. LEVELS, 420 MILS
17071.135105*
17071.135205*
17071.135305*
17071.135405*
17071.136005*
17071.136205*
17071.136505*
17071.137005*
17071.137505*

1/0
2/0
3/0
4/0
250
350
500
750
1000

0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

1.060
1.200
1.245
1.300
1.350
1.450
1.570
1.750
1.900

1.265
1.305
1.355
1.405
1.460
1.555
1.675
1.860
2.010

0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110

2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79

1.47
1.49
1.53
1.59
1.64
1.79
1.91
2.09
2.25

37.34
37.85
38.86
40.39
41.66
45.47
48.5
53.09
57.15

1253
1378
1532
1716
1888
2396
2986
3954
4885

1864
2050
2280
2553
2809
3565
4443
5884
7269

437
525
636
776
899
1217
1690
2477
3263

650
781
946
1155
1338
1811
2515
3685
4855

215
255
290
330
365
440
535
655
755

215
245
275
315
345
415
500
610
690

295
335
380
435
475
575
700
865
1005

5
5
5
5
6
6
6
6
8

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cable in isolated conduit in air, based on a conductor temperature of 105˚C (221˚F) and an
ambient air temperature of 40˚C (104˚F).
(2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature
of 105˚C (221˚F) and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are in accordance with Table 310.60(C)(81) of the NEC for single insulated copper conductors directly buried in earth, based on a conductor temperature of 105˚C (221˚F) and an ambient earth
temperature of 20˚C (68˚F), arrangement per Figure 310.60 Detail 9, 100% load factor, and earth thermal resistance (rho) of 90.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio should be checked for individual installations.
Note: The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

SPEC 6660
April, 2011

Aluminum Uniblend LF
®

EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded
35 kV, UL Type MV-105, 133% Ins. Levels, 420 Mils
Product Construction:
Conductor:

•	1/0 AWG thru 1000 kcmil 1350 aluminum
compact Class B STRANDFILL® blocked
conductor

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with the black conducting
shield layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Metallic Shield:

• 5 mil annealed copper tape with an
overlap of 25%

Jacket:

•	Low-friction, lead-free, flame-retardant, moistureand sunlight-resistant Polyvinyl Chloride (PVC)

Print:

•	GENERAL CABLE® (PLANT OF MFG) (MO/YR
OF MANUFACTURE) LIGHTNING BOLT
SYMBOL 1/C SIZE (AWG OR KCMIL) COMPACT
AL UNIBLEND ® LF PVC JKT (INSULATION
THICKNESS) EPR TYPE MV-105 (VOLTAGE) KV%
INSULATION LEVEL SUN RES FOR CT USE (UL)
SEQUENTIAL FOOTAGE MARK

CATALOG
NUMBER

Applications:

Compliances:

Features:

Packaging:

•	Superior performance in petrochemical plants,
pulp and paper mills, sewage and water
treatment plants, environmental protection
systems, railroads, mines, utility power
generating stations, steel mills, textile plants and
other industrial three-phase applications
• For use in wet or dry locations when installed in
accordance with NEC
• For use in aerial, conduit, open tray and
underground duct installations
•	For use in direct burial if installed in a system with
a ground conductor that is in close proximity, and
conforms with NEC 250.4(A)(5)
•	Rated at 105˚C
•	Lower coefficient of friction for ease of
installation
•	Meets longitudinal water penetration resistance
•	Excellent heat and moisture resistance
•	Excellent flame resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical-resistant
•	Meets cold bend test at -35˚C

•	National Electrical Code (NEC)
•	UL 1072
•	ICEA S-93-639/NEMA WC74
•	ICEA S-97-682
•	AEIC CS8
•	UL listed as Type MV-105 for use in accordance
with NEC, UL File # E90501
•	IEEE 1202 (70,000 BTU/hr)/CSA FT4
•	EPA 40 CFR, Part 261 for leachable lead content
per TCLP method
•	OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)
•	Material cut to length and shipped on
non-returnable wood reels. Lengths in excess of
10,000 lbs. are provided on returnable steel reels
that require a deposit
•	Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and triplexing

NOMINAL INSULATION NOMINAL
NOMINAL CABLE
AMPACITY
COND. CONDUCTOR DIAMETER
CONDUIT
JACKET
SIZE DIAMETER
DIRECT SIZING
WEIGHT
INCHES
THICKNESS DIAMETER
ALUMINUM WEIGHT COPPER WEIGHT CONDUIT
(AWG/
IN AIR UNDERGROUND BURIAL (4)
kcmil) INCHES MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km LBS/1000 FT kg/km (1)
DUCT (2)
(3) (INCHES)

35 kV, UL TYPE MV-105, 133% INS. LEVEL, 420 MILS
17071.135108*
17071.135208*
17071.135308*
17071.135408*
17071.136008*
17071.136208*
17071.136508*
17071.137008*
17071.137508*

1/0
2/0
3/0
4/0
250
350
500
750
1000

0.34
0.38
0.43
0.48
0.53
0.62
0.74
0.91
1.06

1.060 1.265
1.200 1.305
1.245 1.355
1.300 1.405
1.350 1.460
1.450 1.555
1.570 1.675
1.750 1.860
1.900 2.010

0.080
0.080
0.080
0.080
0.080
0.110
0.110
0.110
0.110

2.03
2.03
2.03
2.03
2.03
2.79
2.79
2.79
2.79

1.47
1.49
1.53
1.59
1.64
1.79
1.91
2.09
2.25

37.34
37.85
38.86
40.39
41.66
45.47
48.50
53.09
57.15

1026
1092
1172
1262
1350
1644
1910
2341
2734

1527
1625
1744
1878
2009
2447
2842
3484
4069

99
125
158
199
234
329
468
703
937

147
186
235
296
348
490
696
1046
1394

111
114
118
123
127
136
146
161
175

165
170
175
183
189
202
217
240
260

170
200
225
260
290
350
430
540
640

165
190
215
245
270
330
400
490
565

230
260
295
340
370
450
545
680
795

5
5
5
6
6
6
6
6
8

Dimensions and weights are nominal; subject to industry tolerances.
* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
(1) Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 105°C (221°F) and
an ambient air temperature of 40°C (104°F).
(2) Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor
temperature of 105°C (221°F) and an ambient earth temperature of 20°C (68°F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90.
(3) Ampacities are in accordance with Table 310.60(C)(82) of the NEC for single insulated aluminum conductors directly buried in earth, based on a conductor temperature of 105°C (221°F) and an ambient
earth temperature of 20°C (68°F), arrangement per Figure 310.60 Detail 9, 100% load factor, and earth thermal resistance (rho) of 90.
(4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered, but it should be checked for individual
installations.
Note: The NESC Lightning bolt symbol is on all Uniblend® constructions.

Phone: 888-593-3355
www.generalcable.com

		
Industrial Cables		

Date of Issue 06/13
Section 7

600 V – 35 kV Industrial Armored Cables
SPECIFICATION NO.

PRODUCT DESCRIPTION
®

REVISION DATE

7050†

Duralox

XLPE/AIA/PVC, Control, Armored
600 V, UL Type MC, Multi-Conductor

Jan. 2010

7100†

Duralox®

XLPE/AIA/PVC, Power, Armored
600 V, UL Type MC, Three and Four Conductor (8 AWG - 4/0 AWG)

Jun. 2013

7150†

Duralox®

XLPE/AIA/PVC, Power, Armored
600 V, UL Type MC, Three and Four Conductor (250 kcmil - 1000 kcmil)

Jun. 2013

7160†

Duralox®

XLPE/AIA/PVC, Power, Armored, with Enhanced Ground Wires (50%)
600 V, UL Type MC, Three Conductor (1/0 AWG - 1000 kcmil)

Jun. 2013

7200†

Duralox®

EPR/AIA/PVC, Power, Nonshielded, Armored
2400 V, UL Type MV-90 or MC, Three Conductor

Jan. 2010

7250†

Duralox® Uniblend® EPR/AIA/PVC, Power, Shielded, Armored

Aug. 2010

Duralox® Uniblend® EPR/AIA/PVC, Power, Shielded, Armored

Aug. 2010

Duralox® Uniblend® EPR/AIA/PVC, Power, Shielded, Armored, with Enhanced Ground Wires (50%)

Aug. 2010

Duralox® Uniblend® EPR/AIA/PVC, Power, Shielded, Armored

Aug. 2010

Duralox® Uniblend® EPR/AIA/PVC, Power, Shielded, Armored

Aug. 2010

5 kV/8 kV, UL Type MV-105 or MC, 133%/100% Ins. Levels, 115 Mils, Three Conductor

7300†

15 kV, UL Type MV-105 or MC, 133% Ins. Level, 220 Mils, Three Conductor

7310†

15 kV, UL Type MV-105 or MC, 133% Ins. Level, 220 Mils, Three Conductor

7350

25 kV, UL Type MV-105 or MC, 100% Ins. Level, 260 Mils, Three Conductor

7400

35 kV, UL Type MV-105 or MC, 100% Ins. Level, 345 Mils, Three Conductor

†Indicates

these products are stocked by General Cable

Phone: 888-593-3355
www.generalcable.com

SPEC 7050

January, 2010

Duralox

®

XLPE/AIA/PVC, Control, Armored
600 V, UL Type MC, Multi-Conductor
Product Construction:
Conductor:

•	14 AWG thru 10 AWG bare compressed
copper
•	Class B stranding per ASTM B3 and B8

Insulation:

•	Flame-retardant Cross-linked Polyethylene
(XLPE)
•	Color-coded per ICEA Method 1, Table E-2
	 (does not include white or green)

Options (cont’d.):

Ground:

•	Annealed bare copper Class B stranding per
ASTM B8

Armor:

Applications:

•	In all raceways or direct burial
•	In wet or dry locations
•	Permitted for use in Class I, Division 2; Class II,
Division 2; and Class III, Division 1 and 2 per NEC
Article 334

•	Aluminum Interlocked Armor (AIA)

Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black

Print:

Features:

•	Rated at 90˚C wet or dry
•	Sunlight-resistant
•	Provides excellent oil and chemical resistance
•	Excellent crush resistance
•	Provides a long service life
•	Flame-retardant and resistant to moisture
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend test at -25˚C

•	GENERAL CABLE® XX/C XX AWG (UL) TYPE MC
XHHW-2 CDRS DIR BUR SUN RES FOR CT USE
600 V MONTH-YEAR SEQUENTIAL FOOTAGE
MARK

Options:

•	Tinned copper conductors
•	E-1 color code
•	Copper tape shield or aluminum/polymer tape
shield with tinned copper drain wire over
cable core

CATALOG
NUMBER

MINIMUM
NO. COND. INSULATION
THICKNESS
OF
SIZE
COND. (AWG) INCHES mm

Compliances:

•	Inner jacket only, outer jacket only, or both
•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

NOM. DIA.
GRND.
(OVER)
WIRE
ARMOR
SIZE
(AWG) INCHES
mm

NOMINAL
JACKET
THICKNESS
INCHES
mm

Industry Compliances:
	 • UL 1569
	 • UL 44
	 • ICEA S-95-658/NEMA WC70
	 • UL Type MC-600 volts, UL File # E69797
	 • NEC Type XHHW-2 conductors
Flame Test Compliances:
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels, while lengths in
excess of 10,000 lbs. are provided on returnable
steel reels that require a deposit. Extra charges
apply for cuts less than 1000 ft., lagging, pulling
eyes, paralleling and plexing

NOMINAL
CABLE
O.D.
INCHES
mm

COPPER
NET
WEIGHT
WEIGHT
LBS/1000 FT kg/km LBS/1000 FT kg/km

14 AWG - MULTI-CONDUCTOR - 600 V
346410*
346420
346430*
346440
346450
346460*
346470*
346480*
346490*
346500*

2
3
4
5
7
9
12
19
25
37

14
14
14
14
14
14
14
14
14
14

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

346510*
346520
346530
346540
346550
346560*
346570*
346580*
346590*
346600*

2
3
4
5
7
9
12
19
25
37

12
12
12
12
12
12
12
12
12
12

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

346610
346620

3
4

10
10

0.030
0.030

0.76
0.76

14
14
14
14
14
14
14
14
14
14

0.49
0.52
0.55
0.59
0.64
0.72
0.80
0.99
1.07
1.19

12.5
13.2
14.0
15.0
16.3
18.3
20.3
25.2
27.2
30.3

0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050

1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27

0.60
0.63
0.66
0.69
0.74
0.83
0.90
1.02
1.17
1.29

15.3
16.0
16.8
17.6
18.8
21.1
22.9
25.9
29.7
32.8

39
52
65
79
104
130
168
259
337
492

58
78
97
118
155
193
250
385
502
732

175
183
233
246
297
379
460
621
776
1043

261
273
347
367
443
564
685
924
1155
1533

16.3
16.8
18.1
19.1
20.6
22.6
24.7
28.0
32.5
35.8

64
83
103
129
165
214
279
428
557
793

96
124
154
192
246
319
416
637
829
1180

218
227
272
336
380
479
596
830
1058
1403

324
338
405
500
566
713
887
1235
1575
2088

18.3
19.6

131
164

195
244

301
355

448
529

12 AWG - MULTI-CONDUCTOR - 600 V
12
12
12
12
12
12
12
12
12
12

0.53
0.56
0.60
0.64
0.70
0.78
0.86
0.99
1.18
1.31

13.5
14.3
15.3
16.3
17.8
19.8
21.9
25.2
30.0
33.3

0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050

1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27

0.64
0.66
0.71
0.75
0.81
0.89
0.97
1.10
1.28
1.41

10 AWG - MULTI-CONDUCTOR - 600 V
10
10

0.61
0.66

15.5
16.8

0.050
0.050

1.27
1.27

0.72
0.77

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

SPEC 7100

June, 2013

Duralox

®

XLPE/AIA/PVC, Power, Armored
600 V, UL Type MC, Three and Four Conductor (8 AWG—4/0 AWG)
Compliances:

Product Construction:
Conductors:

Options:

•	Other constructions available upon request

•	8 AWG thru 4/0 AWG bare compressed copper
•	Class B stranding per ASTM B8

Insulation:

•	Cross-linked Polyethylene (XLPE)
•	Color-coded per ICEA Method 3, Table E-2

Ground:

•	Annealed bare copper Class B stranding per
ASTM B8

Armor:

•	Aluminum Interlocked Armor (AIA)

Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black

Print:

•	GENERAL CABLE® SIZE (AWG OR KCMIL) 3/C
OR 4/C (AS APPLICABLE) TYPE MC XHHW-2
CDRS 1/C SIZE AWG GRD SUN RES FOR CT USE
DIR BUR 600 V (UL) MONTH/YEAR SEQUENTIAL
FOOTAGE MARK

CATALOG
NUMBER

Applications:

•	Ideally suited for use in a broad range of
commercial, industrial and utility applications,
where maximum performance is demanded,
ease of installation desired and fire resistance is
critical
•	Permitted for use in Class I; Class II, Division 2;
and Class III, Division 1 and 2 hazardous
locations per the NEC
•	Installed in both exposed or concealed work, wet
or dry locations, indoors or outdoors and cable
trays

Industry Compliances:
	 • UL 1569
	 • UL 44
	 • ICEA S-95-658/NEMA WC70
	 • UL Type MC-600 volts, UL File # E69797
	 • NEC Type XHHW-2 conductors
Flame Test Compliances:
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

Features:

•	Rated at 90˚C wet or dry
•	Provides excellent oil and chemical resistance
•	Excellent crush resistance
•	Provides a long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend test at -25˚C

MINIMUM
GRND. INSULATION
NO. COND. WIRE
THICKNESS
OF
SIZE SIZE
COND. (AWG) (AWG) INCHES mm

NOM. DIA.
(OVER)
ARMOR
INCHES
mm

NOMINAL
JACKET
THICKNESS
INCHES
mm

NOMINAL
CABLE
O.D.
INCHES
mm

COPPER
NET
WEIGHT
WEIGHT
LBS/1000 FT kg/km LBS/1000 FT kg/km

8 AWG - 4/0 AWG - THREE AND FOUR CONDUCTOR - 600 V
346630
346640*
11298.030600
11298.040600*
11298.030400
11298.040400*
11298.030200
11298.040200*
11298.030100*
11298.040100*
11298.035100
11298.045100*
11298.035200
11298.045200*
11298.035300
11298.045300*
11298.035400
11298.045400*

3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4

8
8
6
6
4
4
2
2
1
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0

10
10
8
8
8
8
6
6
6
6
6
6
6
6
4
4
4
4

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055

1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40

0.74
0.80
0.84
0.91
0.94
1.03
1.07
1.18
1.19
1.31
1.27
1.40
1.37
1.51
1.48
1.66
1.66
1.78

18.8
20.3
21.4
23.1
23.9
26.2
27.2
30.0
30.3
33.3
32.3
35.6
34.8
38.2
37.6
42.2
42.2
45.2

0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.050
0.060
0.060

1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.52
1.52

0.84
0.90
0.95
1.01
1.05
1.13
1.18
1.28
1.29
1.41
1.38
1.50
1.48
1.61
1.59
1.78
1.79
1.90

21.4
22.9
24.2
25.6
26.7
28.7
30.0
32.5
32.8
35.9
35.1
38.1
37.6
40.9
40.4
45.3
45.5
48.3

189
241
300
383
447
577
710
919
873
1136
1081
1512
1341
1760
1717
2245
2130
2796

281
359
446
570
665
859
1057
1368
1299
1691
1609
2250
1996
2619
2555
3341
3170
4161

420
507
567
670
757
912
1075
1295
1269
1596
1528
1913
1860
2345
2259
2878
2840
3586

625
755
844
997
1127
1357
1600
1927
1889
2375
2274
2847
2768
3490
3362
4283
4226
5336

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

SPEC 7150

June, 2013

Duralox

®

XLPE/AIA/PVC, Power, Armored	
600 V, UL Type MC, Three and Four Conductor (250 kcmil—1000 kcmil)
Product Construction:
Conductors:

•	250 kcmil thru 1000 kcmil bare compressed
copper  
•	Class B stranding per ASTM B8

Insulation:

•	Cross-linked Polyethylene (XLPE)
•	Color-coded per ICEA Method 3, Table E-2

Applications:

Ground:

•	Annealed bare copper Class B stranding per
ASTM B8

Armor:

•	Aluminum Interlocked Armor (AIA)

Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black

Print:

•	GENERAL CABLE® SIZE (AWG OR KCMIL) 3/C
OR 4/C (AS APPLICABLE) TYPE MC XHHW-2
CDRS 1/C SIZE AWG GRD SUN RES FOR CT USE
DIR BUR 600 V (UL) MONTH/YEAR SEQUENTIAL
FOOTAGE MARK

Options:

•	Other constructions available upon request

CATALOG
NUMBER

NO.
OF
COND.

11298.036000
11298.046000*
11298.036200
11298.046200*
11298.036500
11298.046500*
11298.037000*
11298.047000*
11298.037500*
11298.047500*

3
4
3
4
3
4
3
4
3
4

•	Ideally suited for use in a broad range of
commercial, industrial and utility applications,
where maximum performance is demanded,
ease of installation desired and fire resistance
is critical
•	Permitted for use in Class I; Class II, Division 2;
and Class III, Division 1 and 2 hazardous
locations per the NEC
•	Installed in both exposed or concealed work, wet
or dry locations, indoors or outdoors and cable
trays

Features:

•	Rated at 90˚C wet or dry
•	Provides excellent oil and chemical resistance
•	Excellent crush resistance
•	Provides a long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend test at -25˚C

MINIMUM
GRND. INSULATION
COND. WIRE
THICKNESS
SIZE
SIZE
(AWG) (AWG) INCHES mm

NOM. DIA.
(OVER)
ARMOR
INCHES
mm

NOMINAL
JACKET
THICKNESS
INCHES
mm

Compliances:

Industry Compliances:
	 • UL 1569
	 • UL 44
	 • ICEA S-95-658/NEMA WC70
	 • UL Type MC-600 volts, UL File # E90496
	 • NEC Type XHHW-2 conductors
Flame Test Compliances:
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

NOMINAL
CABLE
O.D.
INCHES
mm

COPPER
NET
WEIGHT
WEIGHT
LBS/1000 FT kg/km LBS/1000 FT kg/km

250 kcmil - 1000 kcmil - THREE AND FOUR CONDUCTOR - 600 V
250
250
350
350
500
500
750
750
1000
1000

4
4
3
3
2
2
1
1
1/0
1/0

0.065
0.065
0.065
0.065
0.065
0.065
0.080
0.080
0.080
0.080

1.65
1.65
1.65
1.65
1.65
1.65
2.03
2.03
2.03
2.03

1.81
1.95
2.03
2.20
2.30
2.51
2.74
3.04
3.07
3.41

46.0
49.5
51.6
55.9
58.5
63.8
69.6
77.2
78.0
86.6

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

0.060
0.060
0.060
0.060
0.075
0.075
0.075
0.075
0.075
0.075

1.52
1.52
1.52
1.52
1.91
1.91
1.91
1.91
1.91
1.91

1.94
2.07
2.16
2.32
2.46
2.66
2.89
3.21
3.24
3.58

49.3
52.6
54.9
59.0
62.5
67.6
73.4
81.6
82.3
91.0

2495
3282
3474
4576
4934
6509
7351
9713
9783
12932

3713
4884
5170
6810
7343
9687
10940
14455
14559
19245

3295
4174
4400
5608
6126
7825
8806
11494
11476
14931

4903
6211
6548
8345
9116
11644
13104
17104
17077
22218

SPEC 7160

June, 2013

Duralox

®

XLPE/AIA/PVC, Power, Armored, with Enhanced Ground Wires (50%)
600 V, UL Type MC, Three Conductor (1/0 AWG—1000 kcmil)
Compliances:

Product Construction:
Conductors:

Options:

•	Other constructions available upon request

Applications:

•	1/0 AWG thru 1000 kcmil bare compressed
copper
•	Class B stranding per ASTM B8

•	Ideally suited for use in a broad range of
commercial, industrial and utility applications,
where maximum performance is demanded,
ease of installation desired and fire resistance
is critical
•	Permitted for use in Class I; Class II, Division
2; and Class III, Division 1 and 2 hazardous
locations per the NEC
•	Installed in both exposed or concealed work, wet
or dry locations, indoors or outdoors and cable
trays

Insulation:

•	Cross-linked Polyethylene (XLPE)
•	Color-coded per ICEA Method 3, Table E-2

Ground:

•	Annealed bare copper Class B stranding per
ASTM B8

Armor:

•	Aluminum Interlocked Armor (AIA)

Packaging:

•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

Features:

Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black

Print:

•	GENERAL CABLE® SIZE (AWG OR KCMIL) 3/C  
TYPE MC XHHW-2 CDRS 1/C SIZE AWG GRD
SUN RES FOR CT USE DIR BUR 600 V (UL)
MONTH/YEAR SEQUENTIAL FOOTAGE MARK

CATALOG
NUMBER

Industry Compliances:
	 • UL 1569
	 • UL 44
	 • ICEA S-95-658/NEMA WC70
	 • UL Type MC-600 volts, UL File # E90496
	 • NEC Type XHHW-2 conductors
Flame Test Compliances:
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

•	Rated at 90˚C wet or dry
•	Provides excellent oil and chemical resistance
•	Excellent crush resistance
•	Provides a long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend test at -25˚C

MINIMUM
GRND. INSULATION
NO.
COND. WIRE
THICKNESS
OF
SIZE
SIZE
COND. (AWG) (AWG) INCHES mm

NOM. DIA.
(OVER)
ARMOR
INCHES
mm

NOMINAL
JACKET
THICKNESS
INCHES
mm

NOMINAL
CABLE
O.D.
INCHES
mm

COPPER
NET
WEIGHT
WEIGHT
LBS/1000 FT kg/km LBS/1000 FT kg/km

1/0 AWG - 1000 kcmil - THREE CONDUCTOR - 600 V
11298.515100*
11298.515200*
11298.515300*
11298.515400*
11298.516000*
11298.516200*
11298.516500
11298.517000*
11298.517500*

3
3
3
3
3
3
3
3
3

1/0
2/0
3/0
4/0
250
350
500
750
1000

3x6
3x6
3x5
3x4
3x4
3x2
3x1
3x2/0
3x3/0

0.055
0.055
0.055
0.055
0.065
0.065
0.065
0.080
0.080

1.40
1.40
1.40
1.40
1.65
1.65
1.65
2.03
2.03

1.27
1.37
1.48
1.66
1.81
2.03
2.30
2.74
3.07

32.3
34.8
37.6
42.2
46.0
51.6
58.5
69.6
78.0

0.050
0.050
0.050
0.060
0.060
0.060
0.075
0.075
0.075

1.27
1.27
1.27
1.52
1.52
1.52
1.91
1.91
1.91

1.38
1.48
1.59
1.79
1.94
2.16
2.46
2.89
3.24

35.1
37.6
40.4
45.5
49.3
54.9
62.5
73.4
82.3

1247
1507
1939
2395
2760
3944
5473
8022
10629

1858
2245
2889
3569
4112
5877
8155
11953
15837

1694
2026
2481
3105
3560
4870
6665
9477
12322

2524
3019
3697
4626
5304
7256
9931
14121
18360

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

SPEC 7200

January, 2010

Duralox

®

EPR/AIA/PVC, Power, Nonshielded, Armored
2400 V, UL Type MV-90 or MC, Three Conductor
Product Construction:
Conductors:

•	6 AWG thru 1000 kcmil bare copper, compact
Class B strand

Extruded Strand Shield (ESS):

•	Extruded thermoset semi-conducting stress
control layer over conductor

Insulation:

Applications:

•	Ethylene Propylene Rubber (EPR), colored to
contrast with black conducting shield layer

Ground:

•	Annealed bare copper Class B stranding per
ASTM B8

Armor:

•	Aluminum Interlocked Armor (AIA)

Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), yellow

Print:

•	GENERAL CABLE® SIZE (KCMIL OR AWG)
COMPACT CU 3/C GENERAL CABLE 115 MILS
EPR TYPE MV-90 OR MC 3/C SIZE AWG GRD
SUN RES FOR CT USE DIR BUR 2400 V NONSHIELDED (UL) MONTH-YEAR LIGHTNING BOLT
SYMBOL SEQUENTIAL FOOTAGE MARK

Options:

•	Other constructions available upon request

CATALOG
NUMBER

NO.
OF
COND.

17471.580600
17471.580400
17471.580200
17471.585100*
17471.585200
17471.585400
17471.586000*
17471.586200
17471.586500
17471.587000*
17471.587500*

3
3
3
3
3
3
3
3
3
3
3

Compliances:

Industry Compliances:
	 • UL 1569
	 • UL 1072
	 • ICEA S-96-659/NEMA WC71
	 • UL Type MV-90, UL File # E90501
	 • UL Type MC, UL File # E90496
Flame Test Compliances:
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-29-520 (210,000 BTU/hr)
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

•	Ideally suited for use in a broad range of
commercial, industrial and utility applications
where reliability is the major concern, maximum
performance will be demanded, space is limited,
ease of installation is critical and fire resistance
is necessary
•	May be installed in wet or dry locations, indoors
or outdoors and in exposed or concealed work
•	May be used in cable trays or on approved
supports in protected areas
•	Permitted for use in Class I; Class II, Division 2;
and Class III, Divisions 1 and 2 hazardous
locations per the NEC

Features:

•	Rated at 90˚C wet or dry
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical- and radiation-resistant
•	Excellent crush resistance
•	Flame or sunlight resistance
•	Cost-effective alternative to installations
in conduit
•	Meets the cold bend test at -25˚C

MINIMUM
GRND.
COND. COND. WIRE INSULATION
THICKNESS
SIZE
DIA. SIZE
(AWG) INCHES (AWG) INCHES mm

NOM. DIA.
(OVER)
ARMOR
INCHES mm

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels, while lengths in
excess of 10,000 lbs. are provided on returnable
steel reels that require a deposit. Extra charges
apply for cuts less than 1000 ft., lagging, pulling
eyes, paralleling and plexing

NOMINAL
JACKET
THICKNESS
INCHES mm

NOMINAL
CABLE
O.D.
INCHES mm

COPPER
NET
WEIGHT
WEIGHT
LBS/1000 FT kg/km LBS/1000 FT kg/km

6 AWG - 1000 kcmil - THREE CONDUCTOR - 115 MILS INS. (2.92 mm) - 2400 V
6
4
2
1/0
2/0
4/0
250
350
500
750
1000

0.17
0.21
0.27
0.34
0.38
0.48
0.52
0.62
0.74
0.91
1.07

6
6
6
4
4
3
3
2
1
1/0
1/0

0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115

2.92
2.92
2.92
2.92
2.92
2.92
2.92
2.92
2.92
2.92
2.92

1.16
1.26
1.37
1.61
1.71
1.92
2.00
2.21
2.46
2.83
3.16

29.4
31.9
34.8
41.0
43.3
48.7
50.7
56.0
62.6
72.0
80.3

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

0.050
0.050
0.050
0.060
0.060
0.060
0.060
0.060
0.075
0.075
0.085

1.27
1.27
1.27
1.52
1.52
1.52
1.52
1.52
1.91
1.91
2.16

1.27
1.37
1.48
1.74
1.84
2.05
2.13
2.34
2.63
3.00
3.35

32.2
34.7
37.6
44.3
46.6
52.0
54.1
59.3
66.7
76.1
85.0

327
473
703
1118
1376
2143
2503
3479
4933
7347
9680

487
704
1047
1665
2049
3191
3727
5180
7345
10940
14414

854
1056
1363
2003
2326
3256
3689
4825
6567
9320
12023

1272
1572
2030
2982
3463
4848
5493
7184
9778
13877
17902

SPEC 7250

August, 2010

Duralox Uniblend
®

®

EPR/AIA/PVC, Power, Shielded, Armored
5 kV/8 kV, UL Type MV-105 or MC, 133%/100% Ins. Levels, 115 Mils, Three Conductor
Features:

Product Construction:
Conductors:

•	6 AWG thru 1000 kcmil bare, copper compact
Class B strand

Extruded Strand Shield (ESS):

•	Thermoset semi-conducting extruded stress
control layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with black conducting layers

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Shield:

•	5 mil annealed copper tape with a minimum 25%
overlap

Ground:

•	Annealed bare copper Class B stranding per
ASTM B8

Armor:

•	Aluminum Interlocked Armor (AIA)

CATALOG
NUMBER

Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), yellow

Print:

•	GENERAL CABLE® SIZE (KCMIL OR AWG)
COMPACT CU 3/C (INS THICKNESS) MILS
EPR TYPE MV-105 OR MC 3/C SIZE AWG GRD
VOLTAGE kV% INS LEVEL SUN RES FOR CT
USE DIR BUR (UL) LIGHTING BOLT SYMBOL
MONTH-YEAR SEQUENTIAL FOOTAGE MARK

Options:

•	Other constructions available upon request

Applications:

•	Ideally suited for use in a broad range of
commercial, industrial and utility applications
where reliability is the major concern, maximum
performance is demanded, space is limited, ease
of installation is critical and fire resistance is
necessary
•	Installed in wet or dry locations, indoors
or outdoors, in exposed or concealed work
•	May be used in cable trays or on approved
support in protected areas
•	Permitted for use in Class I; Class II, Division 2;
and Class III, Divisions 1 and 2 hazardous
locations per the NEC

INSULATION DIAMETER
NO. COND. COND.
MIN.
MAX.
OF SIZE DIA.
COND. (AWG) INCHES INCHES mm INCHES mm

•	Rated at 105˚C wet or dry
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical- and radiation-resistant
•	Excellent crush resistance
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend test at -25˚C

Compliances:

Industry Compliances:
	 • UL 1072
	 • ICEA S-93-639/NEMA WC74
	 • AEIC CS8
	 • UL Type MV-105, UL File # E90501
	 • UL Type MC, UL File # E90496
Flame Test Compliances:
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-29-520 (210,000 BTU/hr)
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels, while lengths in
excess of 10,000 lbs. are provided on returnable
steel reels that require a deposit. Extra charges
apply for cuts less than 1000 ft., lagging, pulling
eyes, paralleling and plexing

DIA.
NOMINAL
NOMINAL
GRND. NOM.
(OVER)
JACKET
CABLE
WIRE
ARMOR
THICKNESS
O.D.
SIZE
(AWG) INCHES mm INCHES mm INCHES mm

COPPER
WEIGHT
LBS/
1000 FT

NET WEIGHT
W/AL ARMOR

kg/
km

LBS/
1000 FT

kg/
km

6 AWG - 1000 kcmil - THREE CONDUCTOR W/JACKET OVER ARMOR, 5 kV, 133% INS. LEVEL OR 8 kV, 100% INS. LEVEL, 115 MILS INS. (2.92 mm)
3
6
0.17
0.42 10.5 0.49 12.5 6
1.33 33.8 0.050 1.27 1.44
36.6
462
688
1133
1687
17473.530600*
3
4
0.21
0.46 11.6 0.54 13.7 6
1.43 36.2 0.050 1.27 1.54
39.1
619
922
1354
2016
17473.530400*
3
2
0.27
0.51 13.0 0.59 14.9 6
1.64 41.6 0.060 1.52 1.77
44.9
864
1286
1819
2708
17473.530200
3
1/0
0.34
0.58 14.7 0.66 16.7 4
1.79 45.3 0.060 1.52 1.92
48.6
1298
1933
2364
3520
17473.535100*
3
2/0
0.38
0.62 15.7 0.70 17.7 4
1.87 47.5 0.060 1.52 2.00
50.8
1566
2332
2696
4014
17473.535200
3
4/0
0.48
0.72 18.3 0.80 20.3 3
2.09 53.2 0.060 1.52 2.22
56.5
2360
3514
3687
5490
17473.535400
3
250
0.52
0.77 19.6 0.85 21.5 3
2.21 56.0 0.060 1.52 2.34
59.3
2735
4072
4165
6202
17473.536000*
3
350
0.62
0.87 22.1 0.95 24.1 2
2.41 61.3 0.075 1.91 2.57
65.4
3736
5563
5436
8094
17473.536200
3
500
0.74
0.99 25.1 1.07 27.1 1
2.64 67.0 0.075 1.91 2.84
72.0
5222
7776
7170
10676
17473.536500
3
750
0.91
1.17 29.7 1.25 31.8 1/0
3.06 77.8 0.085 2.16 3.25
82.4
7684 11441
10084
15015
17473.537000*
3
1000 1.07
1.33 33.8 1.40 35.6 1/0
3.39 86.1 0.085 2.16 3.57
90.8 10057 14975
12793
19049
17473.537500*
Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

SPEC 7300

August, 2010

Duralox Uniblend
®

®

EPR/AIA/PVC, Power, Shielded, Armored
15 kV, UL Type MV-105 or MC, 133% Ins. Level, 220 Mils, Three Conductor
Product Construction:
Conductors:

•	2 AWG thru 1000 kcmil bare, copper compact
Class B strand

Extruded Strand Shield (ESS):

•	Thermoset semi-conducting extruded stress
control layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with black conducting layers

Applications:

•	Ideally suited for use in a broad range of
commercial, industrial and utility applications
where reliability is the major concern, maximum
performance is demanded, space is limited, ease
of installation is critical and fire resistance is
necessary
•	Installed in wet or dry locations, indoors
or outdoors, in exposed or concealed work
•	May be used in cable trays or on approved
support in protected areas
•	Permitted for use in Class I; Class II, Division 2;
and Class III, Divisions 1 and 2 hazardous
locations per the NEC

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Shield:

•	5 mil annealed copper tape with a minimum 25%
overlap

Ground:

•	Annealed bare copper Class B stranding per
ASTM B8

Armor:

Features:

•	Aluminum Interlocked Armor (AIA)

•	Rated at 105˚C wet or dry
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical- and radiation-resistant
•	Excellent crush resistance
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend test at -25˚C

Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), red

Print:

•	GENERAL CABLE® SIZE (KCMIL OR AWG)
COMPACT CU 3/C (INS THICKNESS) MILS
EPR TYPE MV-105 OR MC 3/C SIZE AWG GRD
VOLTAGE kV% INS LEVEL SUN RES FOR CT
USE DIR BUR (UL) LIGHTING BOLT SYMBOL
MONTH-YEAR SEQUENTIAL FOOTAGE MARK

Options:

•	Other constructions available upon request

CATALOG
NUMBER

INSULATION DIAMETER
COND.
NO. SIZE COND.
MIN.
MAX.
OF (AWG/) DIA.
COND. kcmil INCHES INCHES mm INCHES mm

Compliances:

Industry Compliances:
	 • UL 1072
	 • ICEA S-93-639/NEMA WC74
	 • AEIC CS8
	 • UL Type MV-105, UL File # E90501
	 • UL Type MC, UL File # E90496
Flame Test Compliances:
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-29-520 (210,000 BTU/hr)
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels, while lengths in
excess of 10,000 lbs. are provided on returnable
steel reels that require a deposit. Extra charges
apply for cuts less than 1000 ft., lagging, pulling
eyes, paralleling and plexing

DIA.
NOMINAL
NOMINAL
GRND. NOM.
(OVER)
JACKET
CABLE
WIRE
ARMOR
THICKNESS
O.D.
SIZE
(AWG) INCHES mm INCHES mm INCHES mm

COPPER
WEIGHT
LBS/
1000 FT

NET WEIGHT
W/AL ARMOR

kg/
km

LBS/
1000 FT

kg/
km

1368
2013
2412
3594
4153
5643
7856
11522
15055

2416
2997
3371
4502
5005
6252
8091
11086
13870

3597
4463
5019
6703
7452
9309
12047
16507
20652

2 AWG - 1000 kcmil - THREE CONDUCTOR W/JACKET OVER ARMOR, 15 kV, 133% INS. LEVEL, 220 MILS INS. (5.59 mm)
17476.530200
17476.535100*
17476.535200
17476.535400
17476.536000*
17476.536200
17476.536500
17476.537000*
17476.537500*

3
3
3
3
3
3
3
3
3

2
1/0
2/0
4/0
250
350
500
750
1000

0.27
0.34
0.38
0.48
0.53
0.62
0.74
0.91
1.06

0.71
0.78
0.82
0.92
0.97
1.07
1.19
1.37
1.52

18.0
19.8
20.8
23.4
24.6
27.2
30.2
34.8
38.6

0.80
0.87
0.91
1.01
1.06
1.16
1.28
1.46
1.61

20.3
22.0
24.3
25.6
26.9
29.4
32.4
37.1
40.9

6
4
4
3
3
2
1
1/0
1/0

2.08
2.22
2.31
2.53
2.65
2.85
3.11
3.50
3.83

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

52.8
56.5
58.7
64.3
67.2
72.4
79.0
89.0
97.3

0.060
0.060
0.060
0.075
0.075
0.075
0.085
0.085
0.085

1.52
1.52
1.52
1.91
1.91
1.91
2.16
2.16
2.16

2.21
2.35
2.44
2.70
2.81
3.01
3.30
3.69
4.01

56.1
919
59.8 1352
62.0 1620
68.5 2114
71.3 2789
76.6 3790
83.7 5276
93.6 7738
101.9 10111

SPEC 7310

December, 2013

Duralox Uniblend
®

®

EPR/AIA/PVC, Power, Shielded, Armored, with Enhanced Ground Wires (50%)
15 kV, UL Type MV-105 or MC, 133% Ins. Level, 220 Mils, Three Conductor
Features:

Product Construction:
Conductors:

Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), red

•	1/0 AWG thru 1000 kcmil bare, copper compact
Class B strand

Print:

•	GENERAL CABLE® SIZE (KCMIL OR AWG)
COMPACT CU 3/C (INS THICKNESS) MILS
EPR TYPE MV-105 OR MC 3/C SIZE AWG GRD
VOLTAGE kV% INS LEVEL SUN RES FOR CT
USE DIR BUR (UL) LIGHTING BOLT SYMBOL
MONTH-YEAR SEQUENTIAL FOOTAGE MARK

Extruded Strand Shield (ESS):

•	Thermoset semi-conducting extruded stress
control layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with black conducting layers

Options:

Extruded Insulation Shield (EIS):

•	Other constructions available upon request

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Applications:

•	Ideally suited for use in a broad range of
commercial, industrial and utility applications
where reliability is the major concern, maximum
performance is demanded, space is limited, ease
of installation is critical and fire resistance is
necessary
•	Installed in wet or dry locations, indoors
or outdoors, in exposed or concealed work
•	May be used in cable trays or on approved
support in protected areas
•	Permitted for use in Class I; Class II, Division 2;
and Class III, Divisions 1 and 2 hazardous
locations per the NEC

Shield:

•	5 mil annealed copper tape with a minimum 25%
overlap

Ground:

•	Annealed bare copper Class B stranding per
ASTM B8

Armor:

•	Aluminum Interlocked Armor (AIA)

CATALOG
NUMBER

INSULATION DIAMETER
COND.
NO. SIZE COND.
MIN.
MAX.
OF (AWG/) DIA.
COND. kcmil INCHES INCHES mm INCHES mm

•	Rated at 105˚C wet or dry
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical- and radiation-resistant
•	Excellent crush resistance
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend test at -25˚C

Compliances:

Industry Compliances:
	 • UL 1072
	 • ICEA S-93-639/NEMA WC74
	 • AEIC CS8
	 • UL Type MV-105, UL File # E90501
	 • UL Type MC, UL File # E90496
Flame Test Compliances:
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-29-520 (210,000 BTU/hr)
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels, while lengths in
excess of 10,000 lbs. are provided on returnable
steel reels that require a deposit. Extra charges
apply for cuts less than 1000 ft., lagging, pulling
eyes, paralleling and plexing

DIA.
NOMINAL
NOMINAL
GRND. NOM.
(OVER)
JACKET
CABLE
WIRE
ARMOR
THICKNESS
O.D.
SIZE
(AWG) INCHES mm INCHES mm INCHES mm

COPPER
WEIGHT
LBS/
1000FT

NET WEIGHT
W/AL ARMOR

kg/
km

LBS/
1000FT

kg/
km

2187
2603
3962
4683
6272
8647
12767
16674

3119
3499
4752
5265
6674
8550
11932
14957

4644
5210
7076
7840
9938
12731
17767
22271

1/0 AWG - 1000 kcmil - THREE CONDUCTOR W/JACKET OVER ARMOR, 15 kV, 133% INS. LEVEL, 220 MILS INS. (5.59 mm)
17476.515100*
17476.515200*
17476.515400*
17476.516000*
17476.516200*
17476.516500*
17476.517000*
17476.517500*

3
3
3
3
3
3
3
3

1/0
2/0
4/0
250
350
500
750
1000

0.34
0.38
0.48
0.53
0.62
0.74
0.91
1.06

0.78
0.82
0.92
0.97
1.07
1.19
1.37
1.52

19.8
20.8
23.4
24.6
27.2
30.2
34.8
38.6

0.87
0.91
1.01
1.06
1.16
1.28
1.46
1.61

22.0 3x6
24.3 3x6
25.6 3x4
26.9 3x4
29.4 3x2
32.4 3x1
37.1 3x2/0
40.9 3x3/0

2.22
2.31
2.53
2.65
2.85
3.11
3.50
3.83

56.5
58.7
64.3
67.2
72.4
79.0
89.0
97.3

0.060
0.060
0.075
0.075
0.075
0.085
0.085
0.085

1.52
1.52
1.91
1.91
1.91
2.16
2.16
2.16

2.35
2.44
2.70
2.81
3.01
3.30
3.69
4.01

59.8 1469
62.0 1748
68.5 2661
71.3 3145
76.6 4212
83.7 5807
93.6 8574
101.9 11198

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

SPEC 7350

August, 2010

Duralox Uniblend
®

®

EPR/AIA/PVC, Power, Shielded, Armored
25 kV, UL Type MV-105 or MC, 100% Ins. Level, 260 Mils, Three Conductor
Product Construction:
Conductors:

•	1/0 AWG thru 1000 kcmil bare, copper compact
Class B strand

Extruded Strand Shield (ESS):

•	Thermoset semi-conducting extruded stress
control layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with black conducting layers

Applications:

•	Ideally suited for use in a broad range of
commercial, industrial and utility applications
where reliability is the major concern, where
maximum performance is demanded, space is
limited, ease of installation is critical and fire
resistance is necessary
•	Installed in wet or dry locations, indoors
or outdoors, in exposed or concealed work
•	May be used in cable trays or on approved
support in protected areas
•	Permitted for use in Class I; Class II, Division
2; and Class III, Divisions 1 and 2 hazardous
locations per the NEC

Extruded Insulation Shield (EIS):

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Shield:

•	5 mil annealed copper tape with a minimum 25%
overlap

Ground:

•	Annealed bare copper Class B stranding per
ASTM B8

Armor:

Features:

•	Aluminum Interlocked Armor (AIA)

•	Rated at 105˚C wet or dry
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical- and radiation-resistant
•	Excellent crush resistance
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend test at -25˚C

Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), red

Print:

•	GENERAL CABLE® SIZE (KCMIL OR AWG)
COMPACT CU 3/C (INS THICKNESS) MILS
EPR TYPE MV-105 OR MC 3/C SIZE AWG GRD
VOLTAGE kV% INS LEVEL SUN RES FOR CT
USE DIR BUR (UL) LIGHTING BOLT SYMBOL
MONTH-YEAR SEQUENTIAL FOOTAGE MARK

Options:

•	Other constructions available upon request

CATALOG
NUMBER

INSULATION DIAMETER
COND.
NO. SIZE COND.
MIN.
MAX.
OF (AWG/) DIA.
COND. kcmil INCHES INCHES mm INCHES mm

Compliances:

Industry Compliances:
	 • UL 1072
	 • ICEA S-93-639/NEMA WC74
	 • AEIC CS8
	 • UL Type MV-105, UL File # E90501
	 • UL Type MC, UL File # E90496
Flame Test Compliances:
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-29-520 (210,000 BTU/hr)
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels, while lengths in
excess of 10,000 lbs. are provided on returnable
steel reels that require a deposit. Extra charges
apply for cuts less than 1000 ft., lagging, pulling
eyes, paralleling and plexing

DIA.
NOMINAL
NOMINAL
GRND. NOM.
(OVER)
JACKET
CABLE
WIRE
ARMOR
THICKNESS
O.D.
SIZE
(AWG) INCHES mm INCHES mm INCHES mm

COPPER
WEIGHT
LBS/
1000 FT

NET WEIGHT
W/AL ARMOR

kg/
km

LBS/
1000 FT

kg/
km

2043
2443
3626
4184
5675
7887
11552
15087

3358
3743
4807
5307
6595
8485
11491
14303

5000
5573
7158
7902
9820
12634
17110
21297

1/0 AWG - 1000 kcmil - THREE CONDUCTOR W/JACKET OVER ARMOR, 25 kV, 100% INS. LEVEL, 260 MILS INS. (6.60 mm)
17477.535100*
17477.535200*
17477.535400*
17477.536000*
17477.536200*
17477.536500*
17477.537000*
17477.517500*

3
3
3
3
3
3
3
3

1/0
2/0
4/0
250
350
500
750
1000

0.34
0.38
0.48
0.53
0.62
0.74
0.91
1.06

0.85
0.89
0.99
1.04
1.14
1.26
1.44
1.59

21.6
22.6
25.1
26.4
29.0
32.0
36.6
40.4

0.94
0.98
1.08
1.14
1.23
1.35
1.54
1.69

23.9
24.9
27.4
28.8
31.2
34.3
39.0
42.8

4
4
3
3
2
1
1/0
1/0

2.39 60.8
2.48 63.0
2.70 68.6
2.81 71.5
3.02 76.7
3.28 83.3
3.67 93.2
4.00 101.5

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

0.075
0.075
0.075
0.075
0.075
0.085
0.085
0.085

1.91
1.91
1.91
1.91
1.91
2.16
2.16
2.16

2.56
2.64
2.86
2.98
3.18
3.46
3.85
4.18

64.9 1372
67.1 1641
72.7 2435
75.6 2810
80.8 3811
88.0 5297
97.9 7758
106.2 10132

SPEC 7400
August, 2010

Duralox Uniblend
®

®

EPR/AIA/PVC, Power, Shielded, Armored
35 kV, UL Type MV-105 or MC, 100% Ins. Level, 345 Mils, Three Conductor
Features:

Product Construction:
Conductors:

Jacket:

•	Flame-retardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), red

•	1/0 AWG thru 750 kcmil bare, copper compact
Class B strand

Print:

•	GENERAL CABLE® SIZE (KCMIL OR AWG)
COMPACT CU 3/C (INS THICKNESS) MILS
EPR TYPE MV-105 OR MC 3/C SIZE AWG GRD
VOLTAGE kV% INS LEVEL SUN RES FOR CT
USE DIR BUR (UL) LIGHTING BOLT SYMBOL
MONTH-YEAR SEQUENTIAL FOOTAGE MARK

Extruded Strand Shield (ESS):

•	Thermoset semi-conducting extruded stress
control layer over conductor

Insulation:

•	Ethylene Propylene Rubber (EPR) insulation,
colored to contrast with black conducting layers

Options:

Extruded Insulation Shield (EIS):

•	Other constructions available upon request

•	Thermoset semi-conducting polymeric layer free
stripping from insulation

Applications:

•	Ideally suited for use in a broad range of
commercial, industrial and utility applications
where reliability is the major concern, maximum
performance is demanded, space is limited, ease
of installation is critical and fire resistance
is necessary
•	Installed in wet or dry locations, indoors
or outdoors, in exposed or concealed work
•	May be used in cable trays or on approved
support in protected areas
•	Permitted for use in Class I; Class II, Division 2;
and Class III, Divisions 1 and 2 hazardous
locations per the NEC

Shield:

•	5 mil annealed copper tape with a minimum 25%
overlap

Ground:

•	Annealed bare copper Class B stranding per
ASTM B8

Armor:

•	Aluminum Interlocked Armor (AIA)

CATALOG
NUMBER

INSULATION DIAMETER
COND.
NO. SIZE COND.
MIN.
MAX.
OF (AWG/) DIA.
COND. kcmil INCHES INCHES mm INCHES mm

•	Rated at 105˚C wet or dry
•	Excellent heat and moisture resistance
•	Outstanding corona resistance
•	Flexibility for easy handling
•	High dielectric strength
•	Low moisture absorption
•	Electrical stability under stress
•	Low dielectric loss
•	Chemical- and radiation-resistant
•	Excellent crush resistance
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend test at -25˚C

Compliances:

Industry Compliances:
	 • UL 1072
	 • ICEA S-93-639/NEMA WC74
	 • AEIC CS8
	 • UL Type MV-105, UL File # E90501
	 • UL Type MC, UL File # E90496
Flame Test Compliances:
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-29-520 (210,000 BTU/hr)
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • EPA 40 CFR, Part 261 for leachable
lead content per TCLP method
	 • OSHA Acceptable

Packaging:

•	Material cut to length and shipped on
non-returnable wood reels, while lengths in
excess of 10,000 lbs. are provided on returnable
steel reels that require a deposit. Extra charges
apply for cuts less than 1000 ft., lagging, pulling
eyes, paralleling and plexing

DIA.
NOMINAL
NOMINAL
GRND. NOM.
(OVER)
JACKET
CABLE
WIRE
ARMOR
THICKNESS
O.D.
SIZE
(AWG) INCHES mm INCHES mm INCHES mm

COPPER
WEIGHT
LBS/
1000 FT

NET WEIGHT
W/AL ARMOR

kg/
km

LBS/
1000 FT

kg/
km

2113
2512
3696
4253
5745
7957
11622

4063
4441
5572
6165
7499
9400
12843

6050
6613
8297
9180
11166
13997
19123

1/0 AWG - 750 kcmil - THREE CONDUCTOR W/JACKET OVER ARMOR, 35 kV, 100% INS. LEVEL, 345 MILS INS. (8.76 mm)
17480.535100*
17480.535200*
17480.535400*
17480.536000*
17480.536200*
17480.536500*
17480.537000*

3
3
3
3
3
3
3

1/0
2/0
4/0
250
350
500
750

0.34
0.38
0.48
0.53
0.62
0.74
0.91

1.02
1.06
1.16
1.21
1.31
1.43
1.61

25.9
26.9
29.5
30.7
33.3
36.3
40.9

1.12
1.16
1.26
1.32
1.41
1.53
1.71

28.4
29.5
32.0
33.4
35.8
38.9
43.4

4
4
3
3
2
1
1/0

2.77 70.4
2.86 72.6
3.08 78.2
3.19 81.1
3.40 86.3
3.66 93.0
4.05 102.9

0.075
0.075
0.075
0.085
0.085
0.085
0.085

1.91
1.91
1.91
2.16
2.16
2.16
2.16

2.93
3.02
3.24
3.38
3.58
3.83
4.23

74.5
76.7
82.3
85.7
91.0
97.3
107.5

1419
1687
2482
2856
3858
5344
7805

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Phone: 888-593-3355
www.generalcable.com

Date of Issue 06/13
Section 8 		

Industrial Cables

600 V – 28 kV TECK90 Armored Control and Power Cables
SPECIFICATION NO.

PRODUCT DESCRIPTION

8025†

TECK90

XLPE/PVC/AIA/PVC, Control, Armored
600 V, CSA TECK90, Multi-Conductor, 14 AWG

Mar. 2012

8050†

TECK90

XLPE/PVC/AIA/PVC, Control, Armored
600 V, CSA TECK90, Multi-Conductor, 12 AWG

Mar. 2012

8075†

TECK90

XLPE/PVC/AIA/PVC, Control, Armored
600 V, CSA TECK90, Multi-Conductor, 10 AWG

Mar. 2012

8100

TECK90

XLPE/PVC/AIA/PVC, Power, Armored
1000 V, CSA TECK90, Single Conductor

Mar. 2012

8125

TECK90

XLPE/PVC/AIA/PVC, Control and Power, Armored
1000 V, CSA TECK90, Two Conductor

Mar. 2012

8150†

TECK90

XLPE/PVC/AIA/PVC, Control and Power, Armored
1000 V, CSA TECK90, Three Conductor

Mar. 2012

8175†

TECK90

XLPE/PVC/AIA/PVC, Control and Power, Armored
1000 V, CSA TECK90, Four Conductor

Mar. 2012

8200

TECK90

XLPE/PVC/AIA/PVC, Power/Control Composite
600 V, CSA TECK90, Three Power and Three 14 AWG Control Conductors

Mar. 2012

8225

TECK90

TRXLPE/PVC/AIA/PVC, Power, Unshielded, Armored
5 kV, CSA TECK90, 100%/133% Ins. Levels, Single Conductor

Oct. 2012

8250†

TECK90

TRXLPE/PVC/AIA/PVC, Power, Unshielded, Armored
5 kV, CSA TECK90, 100%/133% Ins. Levels, Three Conductor

Jun. 2013

8275

HVTECK

TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored
5 kV, CSA HVTECK, 100%/133% Ins. Levels, 90 Mils, Single Conductor

Oct. 2012

8300

HVTECK

TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored
5 kV, CSA HVTECK, 133% Ins. Level, 115 Mils, Single Conductor

Oct. 2012

8325

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
5 kV, CSA HVTECK, 100%/133% Ins. Levels, 90 Mils, Three Conductor

Oct. 2012

8350

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
5 kV, CSA HVTECK, 133% Ins. Level, 115 Mils, Three Conductor

Oct. 2012

8375

HVTECK

TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 100% Ins. Level, 175 Mils, Single Conductor

Oct. 2012

8400

HVTECK

TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 133% Ins. Level, 220 Mils, Single Conductor

Oct. 2012

8425

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 100% Ins. Level, 175 Mils, Three Conductor

Oct. 2012

†Indicates

these products are stocked by General Cable

Phone: 888-593-3355
www.generalcable.com

REVISION DATE

		
Industrial Cables 		

Date of Issue 06/13
Section 8

600 V – 28 kV TECK90 Armored Control and Power Cables
SPECIFICATION NO.

PRODUCT DESCRIPTION

8450†

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 133% Ins. Level, 220 Mils, Three Conductor

Oct. 2012

8475

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
25 kV, CSA HVTECK, 100% Ins. Level, 260 Mils, Three Conductor

Oct. 2012

8500

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
25 kV, CSA HVTECK, 133% Ins. Level, 320 Mils, Three Conductor

Oct. 2012

8525

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
28 kV, CSA HVTECK, 133% Ins. Level, 345 Mils, Three Conductor

Oct. 2012

8550

VERTITECK® TECK90

XLPE/PVC/GSIA/PVC, Power, Unshielded, Armored
1 kV, CSA TECK90, Three Conductor

Jan. 2010

8575

VERTITECK® TECK90

XLPE/PVC/GSIA/PVC, Power, Unshielded, Armored
5 kV, CSA TECK90, 90 Mils, Three Conductor

Oct. 2012

8600

VERTITECK® HVTECK

TRXLPE/Tape Shield/PVC/GSIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 133% Ins. Level, 220 Mils, Three Conductor

Oct. 2012

8625

VERTITECK® HVTECK

TRXLPE/Tape Shield/PVC/GSIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 100% Ins. Level, 175 Mils, Three Conductor

Oct. 2012

8700†

ACWU

XLPE/AIA/PVC, Control, Armored
600 V, CSA ACWU90 (-40˚C), Single Conductor

Mar. 2012

8750†

ACWU

XLPE/AIA/PVC, Control, Armored
600 V, CSA ACWU90 (-40˚C), Three Conductor

Mar. 2012

8775†

ACWU

XLPE/AIA/PVC, Control, Armored
600 V, CSA ACWU90 (-40˚C), Four Conductor

Mar. 2012

†Indicates

REVISION DATE

these products are stocked by General Cable

Phone: 888-593-3355
www.generalcable.com

SPEC 8025

March, 2012

TECK90

XLPE/PVC/AIA/PVC, Control, Armored
600 V, CSA TECK90, Multi-Conductor, 14 AWG
Product Construction:
Conductors:

•	14 AWG bare copper Class B compressed
concentric round to ASTM B8

Insulation:

•	Cross-linked Polyethylene (XLPE), Type RW90
•	Color-coded: 1 to 4 conductors—black, red,
blue and white; over 4 conductors—per ICEA
Method 4, individual conductors colored black
with conductor number surface printed in
contrasting ink

Options:

Compliances:

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

Ground (Bonding) Conductor:

Applications:

•	The conductor consists of one uninsulated
stranded bare copper conductor

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Aluminum Interlocked Armor (AIA)

Overall Jacket:

Features:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Meets cold bend and impact tests at -40˚C

Print:

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

•	GENERAL CABLE ® ACID-FLAME-CHECK ✓✓ ®
AG14 FT1 FT4 HL TECK90 XLPE (-40˚C)#/C
SIZE (14 AWG) 600 V DIR BUR SUN RES CSA
MONTH-YEAR SEQUENTIAL LENGTH MARK

NOMINAL DIAMETER (OVER)

CATALOG
NUMBER

GROUND
INSULATION
WIRE
SIZE
(AWG) INCHES mm

ARMOR

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

COPPER
WEIGHT

NET WEIGHT W/ARMOR

CABLE

NO.
OF
COND.

COND.
SIZE
(AWG)

2

14

14

0.13

3.4

0.58

14.8

0.67

16.9

39

58

195

310

290

462

25

3

14

14

0.13

3.4

0.60

15.4

0.69

17.4

52

78

226

346

336

515

25

4

14

14

0.13

3.4

0.64

16.2

0.72

18.3

68

101

256

385

381

573

25

5

14

14

0.13

3.4

0.68

17.3

0.76

19.3

81

121

290

430

432

640

20

6

14

14

0.13

3.4

0.72

18.3

0.80

20.3

95

142

316

464

471

691

20

7

14

14

0.13

3.4

0.74

18.8

0.82

20.8

104

155

338

490

503

730

17.5

8

14

14

0.13

3.4

0.79

20.1

0.87

22.2

117

174

373

537

555

799

17.5

10

14

14

0.13

3.4

0.88

22.3

0.96

24.3

149

222

451

637

671

948

17.5

12

14

14

0.13

3.4

0.90

23.0

0.99

25.0

176

262

511

702

761

1045

17.5

15

14

14

0.13

3.4

0.96

24.3

1.04

26.3

217

323

586

791

872

1177

17.5

20

14

14

0.13

3.4

1.13

28.7

1.21

30.8

285

424

789

1117

1174

1662

17.5

25

14

14

0.13

3.4

1.22

30.9

1.30

33.0

337

502

958

1315

1426

1957

15

30

14

14

0.13

3.4

1.28

32.5

1.36

34.6

402

599

1015

1390

1511

2069

15

40

14

14

0.13

3.4

1.40

35.6

1.48

37.7

531

791

1234

1649

1837

2454

15

50

14

14

0.13

3.4

1.52

38.5

1.60

40.6

661

984

1463

1916

2178

2851

12.5

INCHES

mm

INCHES

mm

LBS/
1000 FT

kg/
km

LBS/1000 FT
AL

STEEL

kg/km
AL

STEEL

AMPACITY**
(30˚C
AMBIENT)

14 AWG—MULTI-CONDUCTOR—30 MILS INS. (.76 mm), 600 V
780220
780250
780280
794540
792940
780310
330090
792960
792980
793000
780290
308190*
333750*
330280*
299980*

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**	Ampacity is based on CE Code Part 1, Table 2 for 3 conductors in raceway (conduit). Ampacity of 4 conductor cable is based on 3 current-carrying conductors and 1 neutral.
	 Ampacity at 5 or more conductors is modified by Table 5C.

Phone: 888-593-3355
www.generalcable.com

SPEC 8050

March, 2012

TECK90

XLPE/PVC/AIA/PVC, Control, Armored
600 V, CSA TECK90, Multi-Conductor, 12 AWG
Features:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Meets cold bend and impact tests at -40˚C

Compliances:
Product Construction:
Conductor:

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black

•	12 AWG bare copper Class B compressed
concentric round to ASTM B8

Print:

Insulation:

•	GENERAL CABLE® ACID-FLAME-CHECK ✓✓ ®
AG14 FT1 FT4 HL TECK90 XLPE (-40˚C)#/C
SIZE (12 AWG) 600 V DIR BUR SUN RES CSA
MONTH-YEAR SEQUENTIAL LENGTH MARK

•	Cross-linked Polyethylene (XLPE), Type RW90
•	Color-coded: 1 to 4 conductors­­—black, red,
blue and white; over 4 conductors—per ICEA
Method 4, individual conductors colored black
with conductor number surface printed in
contrasting ink

Options:

Applications:

•	The conductor consists of one uninsulated
stranded bare copper conductor

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Aluminum Interlocked Armor (AIA)

NOMINAL DIAMETER (OVER)
NO.
OF
COND.

COND.
SIZE
(AWG)

Packaging:

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

Ground (Bonding) Conductor:

CATALOG
NUMBER

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

GROUND
INSULATION
WIRE
SIZE
(AWG) INCHES mm

ARMOR
INCHES

mm

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

COPPER
WEIGHT
CABLE

INCHES

mm

LBS/
1000 FT

NET WEIGHT W/ARMOR

kg/
km

LBS/1000 FT
AL

STEEL

kg/km
AL

STEEL

AMPACITY**
(30˚C
AMBIENT)

12 AWG—MULTI-CONDUCTOR—30 MILS INS. (.76 mm), 600 V
780210
780240
780320
312910
331190*
315020*
311560*
304030*
331130*
312990*
299950*
307470*
318730*
346880*
346890*

2

12

14

0.15

3.9

0.62

15.8

0.70

17.9

55

82

228

352

340

524

30

3

12

14

0.15

3.9

0.65

16.4

0.73

18.5

75

112

254

386

378

575

30

4

12

14

0.15

3.9

0.69

17.4

0.77

19.5

96

143

293

434

436

646

30

5

12

14

0.15

3.9

0.73

18.5

0.81

20.6

116

173

350

501

521

746

24

6

12

14

0.15

3.9

0.81

20.5

0.89

22.5

137

204

416

585

619

871

24

7

12

14

0.15

3.9

0.83

21.0

0.91

23.1

157

234

443

616

660

917

21

8

12

14

0.15

3.9

0.86

21.7

0.94

23.8

177

264

492

673

732

1002

21

10

12

14

0.15

3.9

0.95

24.2

1.04

26.2

219

326

555

757

826

1127

21

12

12

14

0.15

3.9

1.01

25.7

1.10

27.8

261

389

653

942

972

1402

21

15

12

14

0.15

3.9

1.07

27.2

1.16

29.3

322

480

757

1065

1127

1585

21

20

12

14

0.15

3.9

1.23

31.3

1.32

33.4

424

631

986

1346

1468

2003

21

25

12

14

0.15

3.9

1.33

33.8

1.42

35.9

527

785

1210

1602

1801

2384

18

30

12

14

0.15

3.9

1.40

35.6

1.49

37.7

630

938

1320

1735

1965

2582

18

40

12

14

0.15

3.9

1.54

39.1

1.64

41.6

837

1246

1725

2185

2567

3252

18

50

12

14

0.15

3.9

1.67

42.4

1.77

44.9

1044

1553

2055

2556

3058

3804

15

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**	Ampacity is based on CE Code Part 1, Table 2 for 3 conductors in raceway (conduit). Ampacity of 4 conductor cable is based on 3 current-carrying conductors and 1 neutral.
	 Ampacity at 5 or more conductors is modified by Table 5C.

Phone: 888-593-3355
www.generalcable.com

SPEC 8075

March, 2012

TECK90

XLPE/PVC/AIA/PVC, Control, Armored
600 V, CSA TECK90, Multi-Conductor, 10 AWG
Product Construction:
Conductor:

•	10 AWG bare copper Class B compressed
concentric round to ASTM B8

Insulation:

•	Cross-linked Polyethylene (XLPE), Type RW90
•	Color-coded: 1 to 4 conductors­­—black, red,
blue and white; over 4 conductors—per ICEA
Method 4, individual conductors colored black
with conductor number surface printed in
contrasting ink

Options:

Compliances:

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

Ground (Bonding) Conductor:

Applications:

•	The conductor consists of one uninsulated
stranded bare copper conductor
•	Color-coded per ICEA Method 4; individual
conductors colored black with conductor number
surface printed in contrasting ink

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Features:

Armor:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Meets cold bend and impact tests at -40˚C

•	Aluminum Interlocked Armor (AIA)

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

Print:

•	GENERAL CABLE® ACID-FLAME-CHECK ✓✓®
AG14 FT1 FT4 HL TECK90 XLPE (-40˚C)#/C
SIZE (10 AWG) 600 V DIR BUR SUN RES CSA
MONTH-YEAR SEQUENTIAL LENGTH MARK

NOMINAL DIAMETER (OVER)
CATALOG
NUMBER

NO.
OF
COND.

COND.
SIZE
(AWG)

GROUND
INSULATION
WIRE
SIZE
(AWG) INCHES mm

ARMOR
INCHES

mm

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

COPPER
WEIGHT
CABLE

INCHES

mm

LBS/
1000 FT

kg/
km

NET WEIGHT W/ARMOR

AL

STEEL

AMPACITY**
(30˚C
AMBIENT)

LBS/1000 FT
AL

STEEL

kg/km

10 AWG—MULTI-CONDUCTOR—30 MILS INS. (.76 mm), 600 V
780200
780230
780270
319480*
333160*
346870*
318740*
311570*
317890*
318750*
308180*
307450*
293570*
307460*
346900*

2

10

12

0.18

4.5

0.67

17.0

0.75

19.0

87

130

275

411

410

612

40

3

10

12

0.18

4.5

0.70

17.7

0.78

19.7

119

177

327

470

487

700

40

4

10

12

0.18

4.5

0.74

18.8

0.83

20.9

150

223

413

565

615

841

40

5

10

12

0.18

4.5

0.82

20.9

0.91

22.9

184

274

473

644

704

959

32

6

10

12

0.18

4.5

0.88

22.2

0.96

24.3

217

323

515

717

766

1066

32

7

10

12

0.18

4.5

0.90

22.9

0.99

25.0

248

369

552

754

821

1122

28

8

10

12

0.18

4.5

0.93

23.6

1.02

25.7

282

420

613

830

912

1235

28

10

10

12

0.18

4.5

1.08

27.3

1.16

29.4

348

518

828

1181

1232

1757

28

12

10

12

0.18

4.5

1.15

29.2

1.23

31.3

414

617

916

1276

1363

1899

28

15

10

12

0.18

4.5

1.22

30.9

1.30

33.0

512

762

1084

1481

1613

2203

28

20

10

12

0.18

4.5

1.36

34.4

1.44

36.5

675

1005

1316

1750

1958

2604

28

25

10

12

0.18

4.5

1.47

37.3

1.55

39.4

835

1243

1612

2099

2399

3124

24

30

10

12

0.18

4.5

1.55

39.4

1.65

41.8

998

1493

1821

2323

2709

3457

24

40

10

12

0.18

4.5

1.71

43.4

1.81

45.9

1321

1966

2278

2837

3390

4222

24

50

10

12

0.18

4.5

1.87

47.5

1.97

49.9

1648

2453

2820

3557

4196

5293

20

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**	Ampacity is based on CE Code Part 1, Table 2 for 3 conductors in raceway (conduit). Ampacity of 4 conductor cable is based on 3 current-carrying conductors and 1 neutral.
	 Ampacity at 5 or more conductors is modified by Table 5C.

Phone: 888-593-3355
www.generalcable.com

SPEC 8100

March, 2012

TECK90

XLPE/PVC/AIA/PVC, Power, Armored
1000 V, CSA TECK90, Single Conductor
Compliances:

Product Construction:
Conductor:

Print:

•	GENERAL CABLE® ACID-FLAME-CHECK ✓✓®
AG14 FT1 FT4 HL TECK90 XLPE (-40˚C)1/C
SIZE (AWG OR KCMIL) 1000 V DIR BUR SUN
RES CSA MONTH-YEAR SEQUENTIAL LENGTH
MARK

•	6 AWG thru 1000 kcmil bare copper compact
Class B strand

Insulation:

•	Cross-linked Polyethylene (XLPE), Type RW90
•	Color-coded: black

Options:

•	Other constructions available upon request

Ground (Bonding) Conductor:

Applications:

•	The conductor is a concentric serving of solid
bare copper wires applied over the insulation

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Aluminum Interlocked Armor (AIA)

Overall Jacket:

CATALOG
NUMBER

NO.
OF
COND.

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

Features:

•	Lead-free, ACID-FLAME-CHECK ✓✓® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black

COND.
SIZE
(AWG/
kcmil)

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost effective alternative to installations in
conduit
•	Meets cold bend and impact tests at -40˚C

MIN. AVG. INS.
GROUND
THICKNESS
WIRE
SIZE
(AWG) INCHES mm

NOMINAL DIAMETER (OVER)
INSULATION
INCHES

mm

ARMOR
INCHES

mm

COPPER
WEIGHT

NET WEIGHT

CABLE
INCHES

mm

LBS/
1000 FT

kg/
km

LBS/1000
FT

kg/km

AMPACITY**
(30˚C
AMBIENT)

6 AWG THRU 1000 kcmil—SINGLE CONDUCTOR—1000 V
11288.040600*
11288.050400*
11288.030300*
11288.050200*
11288.050100*
11288.035100*
11288.035200*
11288.035300*
11288.025400*
11288.026000*
11288.036200*
11288.026500*
11288.027000*
11288.027500*

1

6

8

.060

1.52

0.31

7.8

0.68

17.3

0.77

19.6

137

204

320

470

105

1

4

6

.060

1.52

0.35

8.8

0.73

18.6

0.81

20.6

211

314

410

610

140

1

3

6

.060

1.52

0.38

9.8

0.76

19.3

0.84

21.4

244

363

450

680

165

1

2

6

.060

1.52

0.42

10.5

0.78

19.8

0.87

22.1

286

426

510

760

190

1

1

4

.080

2.03

0.49

12.5

0.88

22.4

0.96

24.4

390

581

680

1010

220

1

1/0

4

.080

2.03

0.53

13.5

0.91

23.2

1.00

25.4

458

682

760

1130

260

1

2/0

4

.080

2.03

0.58

14.7

0.95

24.1

1.04

26.4

544

810

860

1280

300

1

3/0

3

.080

2.03

0.63

15.9

1.03

26.2

1.12

28.5

685

1020

1080

1610

350

1

4/0

3

.080

2.03

0.69

17.5

1.08

27.5

1.17

29.7

820

1220

1270

1890

405

1

250

2

.090

2.29

0.75

19.2

1.21

30.8

1.29

32.8

980

1459

1490

2210

455

1

350

1

.090

2.29

0.86

21.7

1.30

33.0

1.39

35.3

1340

1994

1910

2840

570

1

500

1/0

.090

2.29

0.99

25.0

1.42

36.1

1.51

38.4

1750

2604

2510

3740

700

1

750

2/0

.090

2.29

1.16

29.4

1.59

40.4

1.69

43.0

2570

3825

3510

5230

885

1

1000

2/0

.090

2.29

1.31

33.2

1.81

46.0

1.90

48.3

3340

4970

4430

6590

1055

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on CE Code Part 1, Table 1 (single conductor in free air) and Rule 4-004.

Phone: 888-593-3355
www.generalcable.com

SPEC 8125

March, 2012

TECK90

XLPE/PVC/AIA/PVC, Control and Power, Armored
1000 V, CSA TECK90, Two Conductor
Product Construction:
Conductor:

•	14 AWG thru 8 AWG bare copper Class B
compressed concentric round to ASTM B8
•	6 AWG thru 1000 kcmil bare copper compact
Class B strand

Insulation:

•	Cross-linked Polyethylene (XLPE), Type RW90
•	Color-coded: 14 AWG to 2 AWG—black and
white; 1 AWG to 1000 kcmil—printed numbers

Options:

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Applications:

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Aluminum Interlocked Armor (AIA)

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black

Features:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Meets cold bend and impact tests at -40˚C

Print:

•	GENERAL CABLE® ACID-FLAME-CHECK ✓✓®
AG14 FT1 FT4 HL TECK90 XLPE (-40˚C) 2/C
SIZE (AWG OR KCMIL) 1000 V DIR BUR SUN
RES CSA MONTH-YEAR SEQUENTIAL LENGTH
MARK

CATALOG
NUMBER

COND.
NO.
SIZE
OF
(AWG/
COND. kcmil)

Compliances:

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

NOMINAL DIAMETER (OVER)
COPPER
MIN. AVG. INS.
WEIGHT
GROUND THICKNESS
INSULATION
ARMOR
CABLE
WIRE
SIZE
LBS/
kg/
(AWG) INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT km

NET WEIGHT W/ARMOR
LBS/1000 FT
AL
STEEL

AMPACITY**
kg/km
(30˚C
AL
STEEL AMBIENT)

58

219

350

326

521

25

14 AWG THRU 1000 kcmil—TWO CONDUCTOR—1000 V
794520*
308550*
793140*
331260*
11206.332083*
11288.040400*
11288.220300*
11288.040200*
11288.020100*
11288.045100*
11288.045200*
11288.045300*
11288.145400*
11288.226000*
11288.226200*
11288.226500*
11288.227000*
11288.227500*

2

14

14

.045

1.14

0.17

4.2

0.65

16.5

0.73

18.5

39

2

12

14

.045

1.14

0.18

4.6

0.69

17.6

0.77

19.6

55

82

255

412

380

613

30

2

10

12

.045

1.14

0.21

5.3

0.73

18.5

0.81

20.6

86

128

291

441

433

657

40

2

8

10

.045

1.14

0.24

6.1

0.82

20.8

0.90

22.9

137

204

392

564

584

840

55

2

6

8

.060

1.52

0.31

7.8

0.94

23.9

1.02

25.9

215

320

556

758

827

1128

75

2

4

8

.060

1.52

0.35

8.8

1.07

27.2

1.16

29.5

312

464

744

1052

1107

1565

95

2

3

6

.060

1.52

0.38

9.8

1.15

29.2

1.23

31.3

415

618

905

1239

1347

1844

115

2

2

6

.060

1.52

0.42

10.5

1.20

30.5

1.28

32.5

502

747

1030

1380

1533

2054

130

2

1

6

.080

2.03

0.49

12.5

1.34

34.0

1.42

36.1

612

911

1235

1630

1838

2425

145

2

1/0

6

.080

2.03

0.53

13.5

1.45

36.8

1.53

38.9

740

1101

1425

1854

2120

2759

170

2

2/0

6

.080

2.03

0.58

14.8

1.50

38.1

1.58

40.1

922

1372

1660

2107

2470

3135

195

2

3/0

4

.080

2.03

0.63

15.9

1.59

40.4

1.69

42.9

1190

1771

1995

2471

2969

3677

225

2

4/0

4

.080

2.03

0.69

17.5

1.70

43.2

1.79

45.5

1466

2182

2350

2862

3497

4259

260

2

250

4

.090

2.29

0.75

19.2

1.84

46.8

1.93

49.0

1709

2543

2779

3332

4135

4958

290

2

350

3

.090

2.29

0.86

21.7

2.09

53.1

2.18

55.4

2373

3561

3650

4285

5431

6376

350

2

500

3

.090

2.29

0.99

25.0

2.33

59.2

2.45

62.2

3316

4935

4895

5607

7284

8343

430

2

750

2

.090

2.29

1.16

29.4

2.67

67.8

2.79

70.9

4941

7353

6872

7695 10226 11450

535

2

1000

1

.090

2.29

1.31

33.2

2.98

75.7

3.10

78.8

6562

9766

8993 10376 13382 15439

615

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on CE Code Part 1, Table 2 (Three conductors in raceway [conduit]) and Rule 4-004.

Phone: 888-593-3355
www.generalcable.com

SPEC 8150

November, 2013

TECK90

XLPE/PVC/AIA/PVC, Control and Power, Armored
1000 V, CSA TECK90, Three Conductor
Features:

•	Rated at 90˚C wet or dry
•	Excellent crush resistance, oil and chemical
resistance
•	Provides long service life
•	Meets cold bend and impact tests at -40˚C

Compliances:
Product Construction:
Conductor:

Overall Jacket:

•	14 AWG thru 8 AWG bare copper Class B 	
compressed concentric round to ASTM B8
•	6 AWG thru 1000 kcmil bare copper compact
Class B strand

•	Lead-free, ACID-FLAME-CHECK ✓✓® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black

Print:

•	GENERAL CABLE® ACID-FLAME-CHECK ✓✓® AG14
FT1 FT4 HL TECK90 XLPE (-40˚C) 3/C SIZE (AWG OR
KCMIL) 1000 V DIR BUR SUN RES CSA MONTH-	
YEAR SEQUENTIAL LENGTH MARK

Insulation:

•	Cross-linked Polyethylene (XLPE), Type RW90
•	Color-coded: 14 AWG to 2 AWG—black, red and
blue; 1 AWG to 1000 kcmil—printed numbers

Options:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Applications:

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Aluminum Interlocked Armor (AIA)

COND.
NO.
SIZE
OF
(AWG/
COND. kcmil)

Packaging:

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

Ground (Bonding) Conductor:

CATALOG
NUMBER

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable
•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

NOMINAL DIAMETER (OVER)
COPPER
MIN. AVG. INS.
WEIGHT
GROUND THICKNESS
INSULATION
ARMOR
CABLE
WIRE
SIZE
LBS/
kg/
(AWG) INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT km

NET WEIGHT W/ARMOR
LBS/1000 FT
AL
STEEL

AMPACITY**
kg/km
(30˚C
AL
STEEL AMBIENT)

14 AWG THRU 1000 kcmil—THREE CONDUCTOR—1000 V
330520*
780260
331120
793200
11288.010600
11288.010400
11288.010300
11288.010200
11288.010100
11288.015100
11288.015200
11288.015300
11288.015400
11288.016000
11288.016200
11288.016500
11270.891327
11288.017500*

3

14

14

.045

1.14

0.17

4.2

0.67

17.0

0.76

19.3

52

77

261

398

388

592

25

3

12

14

.045

1.14

0.18

4.6

0.72

18.3

0.80

20.3

75

3

10

12

.045

1.14

0.21

5.3

0.79

20.1

0.88

22.4

124

112

299

445

445

662

30

185

374

539

557

802

3

8

10

.045

1.14

0.24

6.1

0.86

21.9

0.94

23.9

189

281

40

486

666

723

991

55

3

6

8

.060

1.52

0.31

7.8

1.03

26.2

1.13

28.7

300

447

724

836

1078

1244

75

3

4

8

.060

1.52

0.35

8.8

1.16

29.5

1.25

31.8

447

665

970

1327

1444

1975

95

3

3

6

.060

1.52

0.38

9.8

1.22

31.0

1.30

33.0

582

866

1136

1509

1691

2246

115

3

2

6

.060

1.52

0.42

10.5

1.28

32.5

1.37

34.8

710

1056

1311

1702

1951

2533

130

3

1

6

.080

2.03

0.49

12.5

1.44

36.6

1.54

39.1

866

1288

1593

2045

2371

3043

145

3

1/0

6

.080

2.03

0.53

13.5

1.56

39.6

1.68

42.7

1069

1590

1906

2389

2837

3555

170

3

2/0

6

.080

2.03

0.58

14.8

1.65

41.9

1.77

45.0

1327

1974

2225

2732

3311

4066

195

3

3/0

4

.080

2.03

0.63

15.9

1.75

44.5

1.87

47.5

1670

2485

2666

3261

3967

4853

225

3

4/0

4

.080

2.03

0.69

17.5

1.86

47.2

1.98

50.3

2109

3138

3207

3806

4772

5664

260

3

250

4

.090

2.29

0.75

19.2

2.05

52.1

2.17

55.1

2470

3675

3800

4513

5655

6716

290

3

350

3

.090

2.29

0.86

21.7

2.26

57.4

2.40

61.0

3437

5114

4979

5906

7409

8789

350

3

500

3

.090

2.29

0.99

25.0

2.52

64.0

2.66

67.6

4839

7200

6586

7627

9798 11349

430

3

750

2

.090

2.29

1.16

29.4

2.89

73.4

3.03

77.0

7225

10751

9267 10470 13790 15580

535

3

1000

1

.090

2.29

1.31

33.2

3.28

83.3

3.44

87.4

9612

14303 12184 13566 18130 20187

615

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on CE Code Part 1, Table 2 (Three conductors in raceway [conduit]) and Rule 4-004.

Phone: 888-593-3355
www.generalcable.com

SPEC 8175
March, 2012

TECK90

XLPE/PVC/AIA/PVC, Control and Power, Armored
1000 V, CSA TECK90, Four Conductor
Product Construction:
Conductor:

•	14 AWG thru 8 AWG bare copper Class B
compressed concentric round to ASTM B8
•	6 AWG thru 1000 kcmil bare copper compact
Class B strand

Insulation:

•	Cross-linked Polyethylene (XLPE), Type RW90
•	Color-coded: 14 AWG to 2 AWG—black, red,
blue and white; 1 AWG to 1000 kcmil—printed
numbers

Ground (Bonding) Conductor:

Options:

Compliances:

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

Applications:

•	The conductor consists of one uninsulated
stranded bare copper conductor

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Aluminum Interlocked Armor (AIA)

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black

Features:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Meets cold bend and impact tests at -40˚C

Print:

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

•	GENERAL CABLE® ACID-FLAME-CHECK ✓✓ ®
AG14 FT1 FT4 HL TECK90 XLPE (-40˚C) 4/C
SIZE (AWG OR KCMIL) 1000 V DIR BUR
SUN RES CSA MONTH-YEAR SEQUENTIAL
LENGTH MARK

CATALOG
NUMBER

COND.
NO.
SIZE
OF
(AWG/
COND. kcmil)

NOMINAL DIAMETER (OVER)
COPPER
MIN. AVG. INS.
WEIGHT
GROUND THICKNESS
INSULATION
ARMOR
CABLE
WIRE
SIZE
LBS/
kg/
(AWG) INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT km

NET WEIGHT W/ARMOR
LBS/1000 FT
AL
STEEL

AMPACITY**
kg/km
(30˚C
AL
STEEL AMBIENT)

14 AWG THRU 1000 kcmil—FOUR CONDUCTOR—1000 V
321940*
793180*
793160*
331250
11288.030600
11288.020400
11288.020300
11288.020200
11288.040100
11288.025100
11288.025200
11288.025300
11288.045400
11288.046000
11288.026200
11288.036500*
11288.057000*
11288.037500*

4

14

14

.045

1.14

0.17

4.2

0.72

18.3

0.80

20.3

68

101

290

440

430

660

25

4

12

14

.045

1.14

0.18

4.6

0.79

20.1

0.88

4

10

12

.045

1.14

0.21

5.3

0.85

21.6

0.93

22.4

96

143

357

521

531

776

30

23.6

150

223

455

632

677

941

4

8

10

.045

1.14

0.24

6.1

0.92

23.4

1.00

40

25.4

241

359

548

736

816

1096

55

4

6

8

.060

1.52

0.31

7.8

1.15

29.2

1.25

31.8

383

570

907

1261

1350

1877

75

4

4

8

.060

1.52

0.35

8.8

1.26

32.0

1.35

34.3

579

862

1168

1558

1738

2319

95

4

3

6

.060

1.52

0.38

9.8

1.31

33.3

1.40

35.6

748

1113

1373

1782

2043

2652

115

4

2

6

.060

1.52

0.42

10.5

1.37

34.8

1.46

37.1

919

1368

1583

2013

2356

2996

130

4

1

6

.080

2.03

0.49

12.5

1.60

40.6

1.72

43.7

1128

1679

2032

2551

3024

3796

145

4

1/0

6

.080

2.03

0.53

13.5

1.69

42.9

1.81

46.0

1398

2081

2365

2914

3520

4336

170

4

2/0

6

.080

2.03

0.58

14.8

1.79

45.5

1.91

48.5

1742

2593

2745

3331

4085

4957

195

4

3/0

4

.080

2.03

0.63

15.9

1.91

48.5

2.03

51.6

2223

3308

3398

4135

5057

6153

225

4

4/0

4

.080

2.03

0.69

17.5

2.09

53.1

2.21

56.1

2769

4121

4170

4983

6205

7415

260

4

250

4

.090

2.29

0.75

19.2

2.23

56.7

2.35

59.7

3249

4835

4789

5661

7126

8424

290

4

350

3

.090

2.29

0.86

21.7

2.46

62.5

2.60

66.0

4528

6738

6307

7264

9385 10809

350

4

500

3

.090

2.29

0.99

25.0

2.76

70.1

2.90

73.7

6395

9516

8438

9515 12556 14159

430

4

750

2

.090

2.29

1.16

29.4

3.24

82.3

3.42

86.9

9564 14232 12411 13683 18468 20360

535

4

1000

1

.090

2.29

1.31

33.2

3.65

92.7

3.84

97.6 12885 19173 15800 23510 23500 34968

615

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on CE Code Part 1, Table 2 (Three conductors in raceway [conduit]) and Rule 4-004.
Ampacity of 4 conductor cable is based on 3 current-carrying conductors and 1 neutral.

Phone: 888-593-3355
www.generalcable.com

SPEC 8200
March, 2012

TECK90

XLPE/PVC/AIA/PVC, Power/Control Composite
600 V, CSA TECK90, Three Power and Three 14 AWG Control Conductors
Compliances:

Product Construction:
Conductor:

Print:

•	GENERAL CABLE® ACID-FLAME-CHECK ✓✓ ®
AG14 FT1 FT4 HL TECK90 XLPE (-40˚C)3/C
SIZE (AWG) +3/C #14 AWG 600 V DIR BUR SUN
RES CSA MONTH-YEAR SEQUENTIAL LENGTH
MARK

•	12 AWG thru 8 AWG bare copper Class B
compressed concentric round to ASTM B8
•	6 AWG thru 4/0 AWG bare copper compact
Class B strand

Options:

Insulation:

•	Cross-linked Polyethylene (XLPE), Type RW90
•	Color-coded: 14 AWG to 2 AWG—black, red and
blue; 1 AWG to 4/0 AWG—printed numbers

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

Applications:

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as
required by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided
on returnable steel reels that require a deposit.
Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and plexing

Features:

•	Aluminum Interlocked Armor (AIA)

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Meets cold bend and impact tests at -40˚C

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black
®

CATALOG
NUMBER

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

NOMINAL DIAMETER (OVER)
COPPER
MIN. AVG. INS.
WEIGHT
COND. GROUND THICKNESS
INSULATION
ARMOR
CABLE
NO.
SIZE
WIRE
OF (AWG/
SIZE
LBS/
kg/
COND. kcmil) (AWG) INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT km

NET WEIGHT W/ARMOR
LBS/1000 FT
AL STEEL

kg/km
AL STEEL

AMPACITY**
POWER COND.
(30˚C
AMBIENT)

12 AWG THRU 4/0 AWG—THREE POWER CONDUCTORS AND
THREE 14 AWG CONTROL CONDUCTORS—30 MILS (.76 mm)—600 V
333410*†
311320*†
311330*†
11288.210600*
11288.210400*
11288.210200*
11288.210100*
11288.215100*
11288.215200*
11288.215300*
11288.215400*

3

12

14

.030

0.76

0.15

3.9

0.78

19.8

0.86

21.8

114

170

356

519

530

789

30

3

10

12

.030

0.76

0.18

4.5

0.81

20.6

0.89

22.6

158

235

416

586

619

921

40

3

8

10

.045

1.14

0.24

6.1

0.95

24.0

1.00

25.4

208

310

541

729

805 1198

55

3

6

8

.045

1.14

0.28

7.0

0.99

25.0

1.20

30.5

338

503

696

896 1035 1540

75

3

4

8

.045

1.14

0.32

8.2

1.14

28.8

1.25

31.8

485

722

972 1293 1446 2151

95

3

2

6

.045

1.14

0.38

9.7

1.27

32.3

1.39

35.2

747

1112

1295 1662 1927 2868

130

3

1

6

.055

1.40

0.44

11.1

1.39

35.2

1.50

38.1

911

1356

1539 1941 2290 3408

145

3

1/0

6

.055

1.40

0.48

12.2

1.47

37.3

1.59

40.3

1117

1662

1798 2227 2676 3982

170

3

2/0

6

.055

1.40

0.53

13.3

1.57

39.8

1.71

43.3

1378

2051

2150 2609 3199 4760

195

3

3/0

4

.055

1.40

0.58

17.1

1.68

42.5

1.82

46.1

1753

2609

2592 3087 3857 5740

225

3

4/0

4

.055

1.40

0.63

16.0

1.80

45.7

1.94

49.1

2167

3225

3080 3615 4583 6820

260

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
†Contact Customer Service for steel catalog number.
**Ampacity is based on CE Code Part 1, Table 2 (Three conductors in raceway [conduit]) and Rule 4-004.

Phone: 888-593-3355
www.generalcable.com

SPEC 8225
October, 2012

TECK90

TRXLPE/PVC/AIA/PVC, Power, Unshielded, Armored
5 kV, CSA TECK90, 100%/133% Ins. Levels, Single Conductor
Product Construction:
Conductor:

•	6 AWG thru 1000 kcmil bare copper compact
Class B strand

Strand Shield:

•	A thermoset semi-conducting shield is extruded
over the conductor

Insulation:

Options:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE), Type RW90

Compliances:

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

•	Other constructions available upon request

Applications:

Ground (Bonding) Conductor:

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as
required by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands

•	The conductor is a concentric serving of solid
bare copper wires applied over the insulation

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Aluminum Interlocked Armor (AIA)

Features:

Overall Jacket:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Meets cold bend and impact tests at -40˚C

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), orange

Print:

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

•	GENERAL CABLE® ACID-FLAME-CHECK ✓✓ ®
AG14 FT1 FT4 HL TECK90 TRXLPE (-40˚C) 1/C
SIZE (AWG OR KCMIL) 5 kV DIR BUR SUN RES
CSA MONTH-YEAR SEQUENTIAL LENGTH
MARK

NOMINAL DIAMETER (OVER)
NO.
OF
COND.

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

GROUND
WIRE
SIZE
(AWG)

INSULATION
INCHES

mm

ARMOR
INCHES

mm

COPPER
WEIGHT

NET WEIGHT
W/AL ARMOR

CABLE
INCHES

mm

LBS/
1000 FT

kg/
km

LBS/
1000 FT

kg/
km

AMPACITY**
(30˚C
AMBIENT)

6 AWG THRU 1000 kcmil—SINGLE CONDUCTOR—UNSHIELDED—90 MILS INS. (2.29 mm)—5 kV
17496.100600*
17496.100400*
17496.100300*
17496.100200*
17496.100100*
17496.105100*
17496.105200*
17496.105300*
17496.105400*
17496.106000*
17496.106200*
17496.106500*
17496.107000*
17496.107500*

1

6

8

0.39

10.0

0.76

19.3

0.85

21.6

143

213

370

550

105

1

4

6

0.43

10.5

0.84

21.4

0.93

23.7

223

332

490

730

140

1

3

6

0.46

11.7

0.86

21.9

0.95

24.2

229

341

540

800

165

1

2

6

0.49

12.5

0.89

22.6

0.98

24.9

301

448

590

890

190

1

1

4

0.52

13.3

0.93

23.6

1.02

25.9

405

603

720

1060

220

1

1/0

4

0.56

14.2

0.96

24.4

1.06

26.9

474

705

800

1190

260

1

2/0

4

0.60

15.2

1.03

26.2

1.13

28.7

561

835

900

1350

300

1

3/0

3

0.64

16.3

1.08

27.5

1.18

30.0

708

1054

1130

1680

350

1

4/0

3

0.70

17.8

1.16

29.5

1.26

32.0

847

1261

1330

1970

405

1

250

2

0.75

19.1

1.24

31.5

1.34

34.1

1012

1506

1530

2280

455

1

350

1

0.85

21.5

1.34

34.0

1.44

36.6

1388

2066

1960

2910

570

1

500

1/0

0.97

24.6

1.49

37.9

1.59

40.4

1548

2304

2570

3830

700

1

750

2/0

1.15

29.2

1.68

42.7

1.78

45.2

2243

3338

3900

5800

885

1

1000

2/0

1.30

33.0

1.86

47.3

1.96

49.8

2819

4195

4930

7340

1055

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on CE Code Part 1, Table 1 (single conductor in free air) and Rule 4-004.

Phone: 888-593-3355
www.generalcable.com

SPEC 8250

June, 2013

TECK90

TRXLPE/PVC/AIA/PVC, Power, Unshielded, Armored	
5 kV, CSA TECK90, 100%/133% Ins. Levels, Three Conductor
Compliances:

Product Construction:
Conductor:

Print:

•	GENERAL CABLE® ACID-FLAME-CHECK ✓✓ ®
AG14 FT1 FT4 HL TECK90 TRXLPE (-40˚C) 3/C
SIZE (AWG OR KCMIL) 5 kV DIR BUR SUN RES
CSA MONTH-YEAR SEQUENTIAL LENGTH
MARK

•	6 AWG thru 1000 kcmil bare copper compact
Class B strand

Strand Shield:

•	A thermoset semi-conducting shield is extruded
over the conductor

Insulation:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE), Type RW90
•	Color-coded: Black with printed numbers
•	The conductor consists of one uninsulated
stranded bare copper conductor

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), orange

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands

Features:

NOMINAL DIAMETER (OVER)
NO.
OF
COND.

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Meets cold bend and impact tests at -40˚C

•	Aluminum Interlocked Armor (AIA)

COND.
SIZE
(AWG/
kcmil)

Packaging:

Options:

Applications:

Ground (Bonding) Conductor:

CATALOG
NUMBER

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

GROUND
INSULATION
WIRE
SIZE
(AWG) INCHES mm

ARMOR
INCHES

mm

COPPER
WEIGHT
CABLE

INCHES

mm

LBS/
1000 FT

NET WEIGHT W/ARMOR

kg/
km

LBS/1000 FT
AL

STEEL

kg/km
AL

STEEL

AMPACITY**
(30˚C
AMBIENT)

6 AWG THRU 1000 kcmil—THREE CONDUCTOR—UNSHIELDED—90 MILS INS. (2.29 mm)—5 kV
17496.020600
17496.020400
17496.010300*
17496.020200
17496.020100*
17496.025100*
17496.025200
17496.035300*
17496.025400
17496.056000*
17496.026200
17496.046500
17496.077000*
17496.017500*

3

6

8

0.39

10.0

1.27

32.3

1.37

34.8

301

448

927

1340

1380

2000

75

3

4

8

0.43

10.5

1.37

34.8

1.47

37.4

442

658

1138

1590

1694

2370

95

3

3

6

0.46

11.7

1.42

36.1

1.52

38.6

583

868

1310

1780

1950

2640

115

3

2

6

0.49

12.5

1.49

37.9

1.59

40.4

703

1046

1476

1980

2197

2940

130

3

1

6

0.52

13.3

1.59

40.4

1.69

43.0

970

1444

1752

2230

2607

3350

145

3

1/0

6

0.56

14.2

1.67

42.4

1.77

45.0

1082

1610

2012

2540

2994

3780

170

3

2/0

6

0.60

15.2

1.76

44.7

1.86

47.3

1343

1999

2334

2880

3473

4290

195

3

3/0

4

0.64

16.3

1.87

47.5

1.97

50.1

1720

2560

2835

3370

4219

5010

225

3

4/0

4

0.70

17.8

1.98

50.3

2.08

52.9

2315

3445

3328

4090

4952

6090

260

3

250

4

0.75

19.1

2.15

54.6

2.25

57.2

2469

3674

3910

4780

5819

7110

290

3

350

3

0.85

21.5

2.36

60.0

2.49

63.3

3476

5173

5102

6100

7592

9070

350

3

500

3

0.97

24.6

2.62

66.6

2.75

69.9

4837

7198

6721

7880

10001

11720

430

3

750

2

1.15

29.2

3.01

76.5

3.14

79.8

7224

10750

9469

11750

14090

17480

535

3

1000

1

1.30

33.0

3.39

86.1

3.54

89.9

9715

14458

13790

15220

20520

22650

615

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**	Ampacity is based on CE Code Part 1, Table 2 (Three conductors in raceway [conduit]) and Rule 4-004.

Phone: 888-593-3355
www.generalcable.com

SPEC 8275

October, 2012

HVTECK

TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored	
5 kV, CSA HVTECK, 100%/133% Ins. Levels, 90 Mils, Single Conductor
Product Construction:
Conductor:

•	6 AWG thru 1000 kcmil bare copper compact
Class B strand

Strand Shield:

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Insulation:

Print:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Insulation Shield:

•	Black semi-conducting thermosetting layer,
applied in a triple extrusive process, plus a
concentric serving of solid copper wires acting
as both a drain wire shield and a grounding
(bonding) conductor

Ground (Bonding) Conductor:

•	The conductor is a concentric serving of solid
copper wires applied over the thermosetting
insulation shield

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Aluminum Interlocked Armor (AIA)

Compliances:

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
	 • CSA Standard C68.3
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

•	GENERAL CABLE® 1/C SIZE (AWG OR KCMIL)
COPPER CPT TRXLPE 5 kV (100% OR 133%
INS LEVEL) ACID-FLAME-CHECK ✓✓ ® CSA
HL HVTECK (-40˚C) FT4 DIR BUR SUN RES
MONTH/YEAR (LIGHTNING BOLT SYMBOL)
SEQUENTIAL LENGTH MARK

Options:

•	Other constructions available upon request

Applications:

•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

Features:

Overall Jacket:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend and impact tests at -40˚C

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), orange

NOMINAL DIAMETER (OVER)

CATALOG
NUMBER

NO.
OF
COND.

COND. GROUND
INSULATION
SIZE
WIRE
(AWG/
SIZE
kcmil) (AWG) INCHES mm

INSULATION
SHIELD
INCHES

mm

INNER
JACKET

COPPER
WEIGHT

ARMOR

NET WEIGHT
W/AL ARMOR

CABLE

LBS/
INCHES mm INCHES mm INCHES mm 1000 FT

kg/
km

LBS/
1000 FT

kg/
km

AMPACITY**
(40˚C
AMBIENT)

770

112

6 AWG THRU 1000 kcmil—SINGLE CONDUCTOR—SHIELDED,
100%/133% INS. LEVELS, 90 MILS INS. (2.29 mm)—5 kV
17496.700600*
17496.700400*
17496.700200*
17496.700100*
17496.705100*
17496.705200*
17496.705300*
17496.705400*
17496.706000*
17496.706200*
17496.706500*
17496.707000*
17496.707500*

1

6

8

0.39

10.0

0.47

11.9

0.68

17.3

0.90

22.9

0.99

25.2

144

214

510

1

4

6

0.43

10.5

0.51

13.0

0.72

18.3

0.94

23.9

1.03

26.2

224

333

590

880

148

1

2

6

0.49

12.5

0.57

14.5

0.78

19.8

1.03

26.2

1.12

28.5

302

449

750

1120

195

1

1

4

0.52

13.3

0.60

15.3

0.81

20.6

1.06

27.0

1.15

29.2

406

604

870

1300

225

1

1/0

4

0.56

14.2

0.63

16.0

0.88

22.4

1.13

28.7

1.22

31.0

475

707

1010

1500

260

1

2/0

4

0.60

15.2

0.67

17.0

0.92

23.4

1.17

29.7

1.26

32.0

562

836

1120

1670

299

1

3/0

3

0.64

16.3

0.71

18.1

0.97

24.7

1.22

31.0

1.31

33.3

709

1055

1300

1930

345

1

4/0

3

0.70

17.8

0.76

19.3

1.02

25.9

1.27

32.3

1.36

34.6

843

1255

1470

2180

400

1

250

2

0.75

19.1

0.82

20.8

1.10

28.0

1.38

35.1

1.48

37.6 1013

1508

1680

2500

444

1

350

1

0.85

21.5

0.96

24.4

1.24

31.5

1.52

38.6

1.62

41.2 1389

2067

2120

3150

549

1

500

1/0

0.97

24.6

1.04

26.4

1.34

34.0

1.62

41.2

1.72

43.7 1928

2869

2770

4130

688

1

750

2/0

1.15

29.2

1.24

31.5

1.54

39.1

1.83

46.5

1.93

49.0 2820

4197

3780

5760

889

1

1000

2/0

1.30

33.0

1.39

35.3

1.76

44.7

2.05

52.1

2.15

54.6 3607

5368

5010

7460

1061

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on ICEA Publication P 46-426 for 8 kV cables. Open circuit (shield/armor) is assumed. Ampacities at other voltage levels do not vary significantly.
Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).

Phone: 888-593-3355
www.generalcable.com

SPEC 8300

October, 2012

HVTECK

TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored	
5 kV, CSA HVTECK, 133% Ins. Level, 115 Mils, Single Conductor
Features:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provide long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend and impact tests at -40˚C

Compliances:
Product Construction:
Conductor:

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
	 • CSA Standard C68.3
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Armor:

•	Aluminum Interlocked Armor (AIA)

Overall Jacket:

•	6 AWG thru 1000 kcmil bare copper compact
Class B strand

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), orange

Strand Shield:

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Print:

Insulation:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Insulation Shield:

•	Black semi-conducting thermosetting layer,
applied in a triple extrusion process, plus a
concentric serving of solid copper wires acting
as both a drain wire shield and a grounding
(bonding) conductor

Ground (Bonding) Conductor:

•	The conductor is a concentric serving of solid
copper wires applied over the thermosetting
insulation shield

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

•	GENERAL CABLE® 1/C SIZE (AWG OR KCMIL)
COPPER CPT TRXLPE 5 kV (133% INS LEVEL)
ACID-FLAME-CHECK ✓✓ ® CSA HL HVTECK
(-40˚C) FT4 DIR BUR SUN RES MONTH/YEAR
(LIGHTNING BOLT SYMBOL) SEQUENTIAL
LENGTH MARK

Packaging:

Options:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

•	Other constructions available upon request

Applications:

•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)

NOMINAL DIAMETER (OVER)

CATALOG
NUMBER

NO.
OF
COND.

COND. GROUND
INSULATION
SIZE
WIRE
(AWG/
SIZE
kcmil) (AWG) INCHES mm

INSULATION
SHIELD

INNER
JACKET

COPPER
WEIGHT

ARMOR

NET WEIGHT
W/AL ARMOR

CABLE

LBS/
INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT

kg/
km

LBS/
1000 FT

kg/
km

AMPACITY**
(40˚C
AMBIENT)

6 AWG THRU 1000 kcmil—SINGLE CONDUCTOR—SHIELDED,
133% INS. LEVEL, 115 MILS INS. (2.92 mm) (TO AEIC)—5 kV
17496.710600*
17496.710400*
17496.710200*
17496.710100*
17496.715100*
17496.715200*
17496.715300*
17496.715400*
17496.716000*
17496.716200*
17496.716500*
17496.717000*
17496.717500*

1

6

8

0.44

11.2

0.51

13.0

0.73

18.6

0.95

24.2

1.04

26.4

145

216

550

820

112

1

4

6

0.48

12.3

0.55

13.9

0.77

19.6

0.99

25.2

1.08

27.5

225

335

680

1010

148

1

2

6

0.54

13.7

0.61

15.5

0.83

21.1

1.08

27.5

1.17

29.7

303

451

840

1250

195

1

1

4

0.57

14.5

0.64

16.3

0.91

23.0

1.16

29.5

1.25

31.8

407

606

960

1430

225

1

1/0

4

0.61

15.4

0.68

17.3

0.94

23.9

1.19

30.3

1.28

32.5

407

606

1060

1570

260

1

2/0

4

0.65

16.4

0.72

18.3

0.98

25.0

1.23

31.3

1.32

33.6

476

708

1170

1740

299

1

3/0

3

0.70

17.7

0.76

19.3

1.03

26.3

1.31

33.3

1.40

35.6

563

838

1350

2000

345

1

4/0

3

0.75

18.9

0.81

20.6

1.08

27.5

1.36

34.6

1.45

36.9

710

1057

1520

2260

400

1

250

2

0.80

20.3

0.87

22.1

1.16

29.6

1.44

36.6

1.53

38.9

849

1263

1730

2580

444

1

350

1

0.94

23.9

1.01

25.7

1.29

32.8

1.57

39.9

1.67

42.4

1169

1740

2170

3230

549

1

500

1/0

1.02

26.0

1.11

28.2

1.41

35.8

1.69

43.0

1.79

45.6

1390

2069

2860

4260

688

1

750

2/0

1.20

30.6

1.29

32.8

1.60

40.7

1.89

48.0

1.99

50.6

2821

4198

3940

5860

889

1

1000

2/0

1.35

34.3

1.44

36.6

1.81

46.0

2.10

53.4

2.20

55.9

3608

5369

5090

7570

1061

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on ICEA Publication P 46-426 for 8 kV cables. Open circuit (shield/armor) is assumed. Ampacities at other voltage levels do not vary significantly.
Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).

Phone: 888-593-3355
www.generalcable.com

SPEC 8325

October, 2012

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored	
5 kV, CSA HVTECK, 100%/133% Ins. Levels, 90 Mils, Three Conductor
Product Construction:
Conductor:

•	6 AWG thru 1000 kcmil bare copper compact
Class B strand

Strand Shield:

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Insulation:

Print:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Insulation Shield:

•	A semi-conducting thermosetting layer, applied in
a triple extrusion process, plus a helically applied
gapped copper tape
•	Color-coded: black, red or blue colored tape
placed longitudinally under the copper tape
shield

Ground (Bonding) Conductor:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Aluminum Interlocked Armor (AIA)

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), orange

CATALOG
NUMBER

Compliances:

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
	 • CSA Standard C68.3
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Options:

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

Applications:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Inner Jacket:

•	GENERAL CABLE® 3/C SIZE (AWG OR KCMIL)
COPPER CPT TRXLPE 5 kV (100% OR 133%
INS LEVEL) ACID-FLAME-CHECK ✓✓® CSA
HL HVTECK FT4 (-40˚C) DIR BUR SUN RES
MONTH/YEAR (LIGHTNING BOLT SYMBOL)
SEQUENTIAL LENGTH MARK

•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

Features:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend and impact tests at -40˚C

NOMINAL DIAMETER (OVER)
COPPER
WEIGHT
COND. GROUND
INSULATION
INNER
ARMOR
CABLE
NO. SIZE WIRE INSULATION
SHIELD
JACKET
OF (AWG/ SIZE
LBS/ kg/
COND. kcmil) (AWG) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT km

NET WEIGHT
W/ARMOR
LBS/1000 FT
AL STEEL

AMPACITY**
kg/km
(40˚C
AL STEEL AMBIENT)

6 AWG THRU 1000 kcmil—THREE CONDUCTOR—SHIELDED, 100%/133% INS. LEVELS, 90 MILS INS. (2.29 mm)—5 kV
17496.740600*
17496.740400*
17496.740200*
17496.740100*
17496.745100*
17496.745200*
17496.745300*
17496.745400*
17496.746000*
17496.746200*
17496.746500*
17496.747000*
17496.747500*

3

6

8

0.39 10.0 0.47

11.9

1.17

29.7

1.45

36.9

1.54 39.2

349

519 1120 1590 1670 2360

93

3

4

8

0.43

10.5 0.51

13.0

1.26

32.0

1.54

39.1

1.63 41.4

503

749 1350 1850 1670 2760

122

3

2

6

0.49 12.5 0.57

14.5

1.39

35.3

1.67

42.4

1.77 45.0

771

1147 1740 2290 2590 3410

159

3

1

6

0.52 13.3 0.60

15.3

1.45

36.9

1.73

43.9

1.83 46.5

939

1397 1960 2540 2920 3780

184

3

1/0

6

0.56 14.2 0.63

16.0

1.53

38.9

1.81

46.0

1.91 48.5 1148

1708 2290 3010 3410 4490

211

3

2/0

6

0.60 15.2 0.67

17.0

1.62

41.2

1.91

48.5

2.01 51.1 1414

2104 2620 3380 3900 5030

243

3

3/0

4

0.64 16.3 0.71

18.1

1.78

45.2

2.07

52.6

2.17 55.1 1798

2668 3210 4040 4780 6020

279

3

4/0

4

0.70 17.8 0.76

19.3

1.90

48.3

2.19

55.6

2.29 58.2 2212

3292 3720 4600 5530 6840

321

3

250

4

0.75 19.1 0.82

20.8

2.01

51.1

2.30

58.4

2.43 61.8 2583

3844 4300 5240 6400 7800

355

3

350

3

0.85 21.5 0.96

24.4

2.32

58.9

2.61

66.3

2.74 69.6 3569

5311 5480 6520 8160 9700

435

3

500

3

0.97 24.6 1.04

26.4

2.48

63.0

2.77

70.4

2.90 73.7 4998

7438 7130 8280 10610 12320

536

3

750

2

1.15 29.2 1.24

31.5

2.98

75.7

3.27

83.1

3.42 86.9 7440 11072 10330 11700 15370 17410

668

3

1000

1

1.30 33.0 1.39

35.3

3.31

84.1

3.60

91.5

3.75 95.3 9860 14674 13080 14600 19460 21730

768

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on ICEA Publication P 46-426 for 8 kV cables. Ampacities at other voltage levels do not vary significantly.
Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).

Phone: 888-593-3355
www.generalcable.com

SPEC 8350

October, 2012

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored	
5 kV, CSA HVTECK, 133% Ins. Level, 115 Mils, Three Conductor
Features:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend and impact tests at -40˚C

Compliances:
Product Construction:
Conductor:

Armor:

•	Aluminum Interlocked Armor (AIA)

•	6 AWG thru 1000 kcmil bare copper compact
Class B strand

Strand Shield:

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Insulation:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Insulation Shield:

•	A semi-conducting thermosetting layer, applied in
a triple extrusion process, plus a helically applied
gapped copper tape
•	Color-coded: black, red or blue colored tape
placed longitudinally under the copper tape
shield

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

CATALOG
NUMBER

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), orange

Print:

•	GENERAL CABLE® 3/C SIZE (AWG OR KCMIL)
COPPER CPT TRXLPE 5 kV (133% INS LEVEL)
ACID-FLAME-CHECK ✓✓ ® CSA HL HVTECK
FT4 (-40˚C) DIR BUR SUN RES MONTH/YEAR
(LIGHTNING BOLT SYMBOL) SEQUENTIAL
LENGTH MARK

Options:

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

Applications:

•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
	 • CSA Standard C68.3
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

NOMINAL DIAMETER (OVER)
COPPER
WEIGHT
COND. GROUND
INSULATION
INNER
ARMOR
CABLE
NO. SIZE WIRE INSULATION
SHIELD
JACKET
OF (AWG/ SIZE
LBS/ kg/
COND. kcmil) (AWG) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT km

NET WEIGHT
W/ARMOR
LBS/1000 FT
AL STEEL

AMPACITY**
kg/km
(40˚C
AL STEEL AMBIENT)

6 AWG THRU 1000 kcmil—THREE CONDUCTOR—SHIELDED, 133% INS. LEVEL,
115 MILS INS. (2.92 mm) (TO AEIC)—5 kV
17496.750600*
17496.750400*
17496.750200*
17496.750100*
17496.755100*
17496.755200*
17496.755300*
17496.755400*
17496.756000*
17496.756200*
17496.756500*
17496.757000*
17496.757500*

3

6

8

0.44 11.2 0.51

13.0

1.27

32.3

1.55

39.4

1.65 41.9

352

524

1270 1780 1890 2650

93

3

4

8

0.48 12.3 0.55

13.9

1.37

34.8

1.65

41.9

1.75 44.5

505

752

1500 2040 2230 3040

122

3

2

6

0.54 13.7 0.61

15.5

1.50

38.2

1.78

45.2

1.88 47.8

774

1152

1930 2630 2870 3910

159

3

1

6

0.57 14.5 0.64

16.3

1.57

39.9

1.86

47.3

1.96 49.8

943

1403

2150 2880 3200 2490

184

3

1/0

6

0.61 15.4 0.68

17.3

1.65

41.9

1.94

49.3

2.04 51.8 1151

1713

2430 3200 3620 4760

211

3

2/0

6

0.65 16.4 0.72

18.3

1.80

45.6

2.09

53.1

2.19 55.7 1417

2109

2890 3720 4300 5540

243

3

3/0

4

0.70 17.7 0.76

19.3

1.90

48.3

2.19

55.7

2.29 58.2 1796

2673

3360 4240 5000 6310

279

3

4/0

4

0.75 18.9 0.81

20.6

2.01

51.0

2.30

58.5

2.43 61.8 2215

3296

3940 4870 5860 7240

321

3

250

4

0.80 20.3 0.87

22.1

2.13

54.1

2.42

61.5

2.55 64.8 2583

3844

4470 5450 6650 8120

355

3

350

3

0.94 23.9 1.01

25.7

2.43

61.8

2.72

69.1

2.85 72.4 3572

5316

5650 6730 8400 10020

435

3

500

3

1.02 26.0 1.11

28.2

2.64

67.1

2.93

74.5

3.06 77.8 5004

7447

7440 8660 11070 12880

536

3

750

2

1.20 30.6 1.29

32.8

3.10

78.8

3.39

86.1

3.54 89.9 7431 11059 10560 11980 15710 17830

668

3

1000

1

1.35 34.3 1.44

36.6

3.42

86.9

3.71

94.3

3.86 98.1 9863 14678 13300 14870 19790 22130

768

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on ICEA Publication P 46-426 for 8 kV cables. Ampacities at other voltage levels do not vary significantly.
Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).

Phone: 888-593-3355
www.generalcable.com

SPEC 8375

October, 2012

HVTECK

TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored	
15 kV, CSA HVTECK, 100% Ins. Level, 175 Mils, Single Conductor
Product Construction:
Conductor:

•	2 AWG thru 1000 kcmil bare copper compact
Class B strand

Strand Shield:

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Insulation:

Print:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

•	GENERAL CABLE® 1/C SIZE (AWG OR KCMIL)
COPPER CPT TRXLPE 15 kV (100% INS LEVEL)
ACID-FLAME-CHECK ✓✓ ® CSA HL HVTECK
FT4 (-40˚C) DIR BUR SUN RES MONTH/YEAR
(LIGHTNING BOLT SYMBOL) SEQUENTIAL
LENGTH MARK

Insulation Shield:

•	Black semi-conducting thermosetting layer,
applied in a triple extrusion process, plus a
concentric serving of solid copper wires acting
as both a drain wire shield and a grounding
(bonding) conductor

Ground (Bonding) Conductor:

•	The conductor is a concentric serving of solid
copper wires applied over the thermosetting
insulation shield

Options:

•	Other constructions available upon request

Applications:

•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Aluminum Interlocked Armor (AIA)

Features:

Overall Jacket:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend and impact tests at -40˚C

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), red

Compliances:

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
	 • CSA Standard C68.3
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

NOMINAL DIAMETER (OVER)

CATALOG
NUMBER

COPPER
WEIGHT
COND. GROUND
INSULATION
INNER
INSULATION
ARMOR
CABLE
NO.
SIZE
WIRE
SHIELD
JACKET
OF (AWG/
SIZE
LBS/ kg/
COND. kcmil) (AWG) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT km

NET WEIGHT
W/AL ARMOR
LBS/
1000 FT

kg/
km

AMPACITY**
(40˚C
AMBIENT)

2 AWG THRU 1000 kcmil—SINGLE CONDUCTOR—100% INS. LEVELS, 175 MILS INS. (4.45 mm)—15 kV
17496.810200*
17496.810100*
17496.815100*
17496.815200*
17496.815300*
17496.815400*
17496.816000*
17496.816200*
17496.816500*
17496.817000*
17496.817500*

1

2

6

0.66

16.7

0.73

18.6

0.99

25.3

1.24

31.5

1.33

33.8

259

385

950

1420

195

1

1

4

0.69

17.5

0.76

19.3

1.03

26.1

1.28

32.5

1.37

34.8

391

582

1080

1600

225

1

1/0

4

0.73

18.5

0.80

20.3

1.06

27.0

1.31

33.3

1.40

35.6

460

685

1170

1750

259

1

2/0

4

0.77

19.5

0.84

21.3

1.10

27.9

1.35

34.3

1.44

36.6

545

811

1290

1920

298

1

3/0

3

0.82

20.8

0.88

22.4

1.15

29.2

1.40

35.6

1.49

37.9

688 1024

1470

2190

343

1

4/0

3

0.87

22.0

0.94

23.9

1.21

30.6

1.46

37.1

1.55

39.4

824 1226

1640

2450

397

1

250

2

0.93

23.5

0.99

25.2

1.28

32.5

1.53

38.9

1.63

41.4

944 1405

1900

2830

440

1

350

1

1.07

27.2

1.15

29.2

1.43

36.3

1.71

43.5

1.81

46.0

1352 2012

2370

3530

543

1

500

1/0

1.14

29.0

1.23

31.2

1.54

39.1

1.83

46.5

1.93

49.1

1887 2808

3080

4590

678

1

750

2/0

1.32

33.6

1.41

35.9

1.78

45.2

2.07

52.6

2.17

55.2

2754 4099

4240

6320

872

1

1000

2/0

1.48

37.6

1.57

39.9

1.93

49.0

2.22

56.4

2.32

59.0

3532 5256

5280

7860

1040

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on ICEA Publication P 46-426 for 15 kV cables. Open circuit (shield/armor) is assumed. Ampacities at other voltage levels do not vary significantly.
Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).

Phone: 888-593-3355
www.generalcable.com

SPEC 8400
October, 2012

HVTECK

TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 133% Ins. Level, 220 Mils, Single Conductor
Features:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend and impact tests at -40˚C

Compliances:
Product Construction:
Conductor:

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
	 • CSA Standard C68.3
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Armor:

•	Aluminum Interlocked Armor (AIA)

Overall Jacket:

•	2 AWG thru 1000 kcmil bare copper compact
Class B strand

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), red

Strand Shield:

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Print:

•	GENERAL CABLE® 1/C SIZE (AWG OR KCMIL)
COPPER CPT TRXLPE 15 kV (133% INS LEVEL)
ACID-FLAME-CHECK ✓✓ ® CSA HL HVTECK
FT4 (-40˚C) DIR BUR SUN RES MONTH/YEAR
(LIGHTNING BOLT SYMBOL) SEQUENTIAL
LENGTH MARK

Insulation:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Insulation Shield:

•	Black semi-conducting thermosetting layer,
applied in a triple extrusion process, plus a
concentric serving of solid copper wires acting
as both a drain wire shield and a grounding
(bonding) conductor

Options:

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

•	Other constructions available upon request

Applications:

•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)

Ground (Bonding) Conductor:

•	The conductor is a concentric serving of solid
copper wires applied over the thermosetting
insulation shield

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

NOMINAL DIAMETER (OVER)

CATALOG
NUMBER

COPPER
WEIGHT
COND. GROUND
INSULATION
INNER
INSULATION
ARMOR
CABLE
NO.
SIZE
WIRE
SHIELD
JACKET
OF (AWG/
SIZE
LBS/ kg/
COND. kcmil) (AWG) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT km

NET WEIGHT
W/AL ARMOR
LBS/
1000 FT

kg/
km

AMPACITY**
(40˚C
AMBIENT)

2 AWG THRU 1000 kcmil—SINGLE CONDUCTOR—133% INS. LEVELS, 220 MILS INS. (5.59 mm)—15 kV
17496.216500*
17496.820100*
17496.825100*
17496.825200*
17496.825300*
17496.825400*
17496.826000*
17496.826200*
17496.826500*
17496.827000*
17496.827500*

1

2

6

0.76

19.3

0.83

21.1

1.09

27.7

1.34

34.1

1.43

36.4

286

426

1028

1530

195

1

1

4

0.79

20.1

0.86

21.9

1.12

28.4

1.37

34.8

1.46

37.1

391

582

1170

1740

225

1

1/0

4

0.83

21.1

0.89

22.6

1.16

29.4

1.41

35.8

1.50

38.1

459

683

1270

1890

259

1

2/0

4

0.86

21.8

0.93

23.6

1.20

30.4

1.45

36.9

1.54

39.2

546

813

1390

2060

298

1

3/0

3

0.91

23.0

0.98

24.9

1.25

31.7

1.50

38.1

1.59

40.4

693 1031

1570

2340

343

1

4/0

3

0.96

24.3

1.03

26.2

1.30

33.0

1.58

40.2

1.68

42.7

830 1235

1780

2650

397

1

250

2

1.02

25.8

1.08

27.5

1.38

35.0

1.66

42.2

1.76

44.7

989 1472

2010

2990

440

1

350

1

1.12

28.3

1.20

30.5

1.50

38.0

1.78

45.2

1.88

47.8

1228 1827

2490

3700

543

1

500

1/0

1.24

31.5

1.32

33.6

1.65

41.8

1.94

49.3

2.04

51.9

1896 2821

3220

4790

678

1

750

2/0

1.42

36.0

1.51

38.3

1.89

48.0

2.18

55.4

2.28

57.9

2766 4116

4390

6530

872

1

1000

2/0

1.57

39.9

1.68

42.6

2.05

52.1

2.34

59.5

2.48

63.0

3552 5286

5550

8260

1040

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on ICEA Publication P 46-426 for 15 kV cables. Open circuit (shield/armor) is assumed. Ampacities at other voltage levels do not vary significantly.
Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).

Phone: 888-593-3355
www.generalcable.com

SPEC 8425

October, 2012

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 100% Ins. Level, 175 Mils, Three Conductor
Product Construction:
Conductor:

•	2 AWG thru 1000 kcmil bare copper compact
Class B strand

Strand Shield:

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Insulation:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Insulation Shield:

•	This consists of a semi-conducting thermosetting
layer, applied in a triple extrusion process, plus a
helically applied gapped copper tape
•	Color-coded: black, red or blue colored tape
placed longitudinally under the copper tape
shield

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Aluminum Interlocked Armor (AIA)

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), red

CATALOG
NUMBER

Print:

•	GENERAL CABLE® 3/C SIZE (AWG OR KCMIL)
COPPER CPT TRXLPE 15 kV (100% INS LEVEL)
ACID-FLAME-CHECK ✓✓ ® CSA HL HVTECK
FT4 (-40˚C) DIR BUR SUN RES MONTH/YEAR
(LIGHTNING BOLT SYMBOL) SEQUENTIAL
LENGTH MARK

Compliances:

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
	 • CSA Standard C68.3
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Options:

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

Applications:

•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

Features:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend and impact tests at -40˚C

NOMINAL DIAMETER (OVER)
COPPER
WEIGHT
COND. GROUND
INSULATION
INNER
ARMOR
CABLE
NO. SIZE WIRE INSULATION
SHIELD
JACKET
OF (AWG/ SIZE
LBS/ kg/
COND. kcmil) (AWG) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT km

NET WEIGHT
W/ARMOR
LBS/1000 FT
AL STEEL

AMPACITY**
kg/km
(40˚C
AL STEEL AMBIENT)

2 AWG THRU 1000 kcmil—THREE CONDUCTOR—100% INS. LEVELS, 175 MILS INS. (4.45 mm)—15 kV
17496.030200*
17496.830100*
17496.835100*
17496.835200*
17496.835300*
17496.835400*
17496.836000*
17496.836200*
17496.536500*
17496.837000*
17496.837500*

3

2

6

0.66 16.7 0.73

18.6

1.82

46.3

2.11

53.6

2.21 56.2

787

1171 2370 3220 3530 4790

164

3

1

6

0.69 17.5 0.76

19.3

1.89

48.0

2.18

55.4

2.27 57.7

955

1421 2620 3490 3890 5190

187

3

1/0

6

0.73 18.5 0.79

20.1

1.97

50.0

2.26

57.4

2.35 59.7 1163

1731 2900 3810 4320 5670

215

3

2/0

6

0.77 19.5 0.84

21.3

2.06

52.3

2.34

59.5

2.46 62.5 1429

2127 3330 4280 4960 6370

246

3

3/0

4

0.82 20.8 0.88

22.4

2.16

54.9

2.44

62.0

2.57 65.3 1812

2697 3840 4840 5720 7200

283

3

4/0

4

0.87 22.0 0.93

23.7

2.27

57.7

2.56

65.1

2.68 68.1 2228

3316 4360 5410 6490 8050

325

3

250

4

0.93 23.5 0.99

25.2

2.38

60.5

2.68

68.1

2.79 70.9 2598

3866 4880 5990 7260 8910

359

3

350

3

1.06 26.9 1.15

29.2

2.73

69.4

3.02

76.7

3.14 79.8 3587

5338 6210 7430 9240 11060

438

3

500

3

1.14 29.0 1.23

31.2

2.97

75.5

3.26

82.8

3.40 86.4 5013

7460 8549 9550 12721 14200

536

3

750

2

1.32 33.6 1.41

35.9

3.35

85.1

3.64

92.5

3.77 95.8 7446 11081 11100 12640 16520 18810

669

3

1000

1

1.47 37.4 1.56

39.6

3.72

94.5

3.97 100.8 4.17 105.9 9376 13953 13890 15580 20670 23180

770

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on ICEA Publication P 46-426 for 15 kV cables. Ampacities at other voltage levels do not vary significantly.
Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).

Phone: 888-593-3355
www.generalcable.com

SPEC 8450
October, 2012

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 133% Ins. Level, 220 Mils, Three Conductor
Features:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend and impact tests at -40˚C

Compliances:
Product Construction:
Conductor:

Armor:

•	Aluminum Interlocked Armor (AIA)

•	2 AWG thru 750 kcmil bare copper compact
Class B strand

Strand Shield:

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Insulation:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Insulation Shield:

•	This consists of a semi-conducting thermosetting
layer, applied in a triple extrusion process, plus a
helically applied gapped copper tape
•	Color-coded: black, red or blue colored tape
placed longitudinally under the copper tape
shield

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

CATALOG
NUMBER

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), red

Print:

•	GENERAL CABLE® 3/C SIZE (AWG OR KCMIL)
COPPER CPT TRXLPE 15 kV (133% INS LEVEL)
ACID-FLAME-CHECK ✓✓ ® CSA HL HVTECK
FT4 (-40˚C) DIR BUR SUN RES MONTH/YEAR
(LIGHTNING BOLT SYMBOL) SEQUENTIAL
LENGTH MARK

Options:

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other options available upon request

Applications:

•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
	 • CSA Standard C68.3
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

NOMINAL DIAMETER (OVER)
COPPER
WEIGHT
COND. GROUND
INSULATION
INNER
ARMOR
CABLE
NO. SIZE WIRE INSULATION
SHIELD
JACKET
OF (AWG/ SIZE
LBS/ kg/
COND. kcmil) (AWG) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT km

NET WEIGHT
W/ARMOR
LBS/1000 FT
AL STEEL

AMPACITY**
kg/km
(40˚C
AL STEEL AMBIENT)

2 AWG THRU 750 kcmil—THREE CONDUCTOR—133% INS. LEVEL, 220 MILS INS. (5.59 mm)—15 kV
17496.230200*
17496.010100*
17451.316781*
17496.015200*
17496.025300*
17496.035400*
17496.026000*
17496.046200
17496.056500
17496.037000

3

2

6

0.76 19.3 0.83

21.1

2.02

51.3

2.31

58.7

2.43

61.7

793 1180 2665 3518 3966 5235

164

3

1

6

0.79 20.1 0.86

21.9

2.10

53.3

2.37

60.2

2.49

63.3

964 1435 3089 3930 4597 5850

187

3

1/0

6

0.83 21.1 0.89

22.6

2.17

55.1

2.46

62.5

2.58

65.6 1175 1749 3300 4300 4900 6390

215

3

2/0

6

0.86 21.8 0.93

23.6

2.26

57.3

2.55

64.8

2.67

67.8 1438 2140 3650 4690 5430 6980

246

3

3/0

4

0.91 23.0 0.98

24.9

2.36

60.0

2.65

67.3

2.77

70.4 1821 2710 4140 5230 6160 7780

283

3

4/0

4

0.96 24.3 1.03

26.2

2.47

62.8

2.76

70.1

2.88

73.2 2248 3345 4680 5810 6960 8650

325

3

250

4

1.02 25.8 1.08

27.5

2.59

65.8

2.88

73.2

3.00

76.2 2607 3880 5275 6440 7850 9580

359

3

350

3

1.12 28.3 1.20

30.5

2.90

73.7

3.19

81.0

3.33

84.6 3597 5353 6842 8170 10181 12160

438

3

500

3

1.24 31.5 1.32

33.6

3.16

80.3

3.45

87.6

3.59

91.2 5022 7474 8513 10050 12668 14950

536

3

750

2

1.42 36.0 1.51

38.3

3.57

90.7

3.85

97.8

4.00 101.6 7452 11090 11507 13160 17122 19580

669

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on ICEA Publication P 46-426 for 15 kV cables. Ampacities at other voltage levels do not vary significantly.
Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).

Phone: 888-593-3355
www.generalcable.com

SPEC 8475

October, 2012

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored
25 kV, CSA HVTECK, 100% Ins. Level, 260 Mils, Three Conductor
Product Construction:
Conductor:

•	1 AWG thru 500 kcmil bare copper compact
Class B strand

Strand Shield:

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Insulation:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Insulation Shield:

•	This consists of a semi-conducting thermosetting
layer, applied in a triple extrusion process, plus a
helically applied gapped copper tape
•	Color-coded: black, red or blue colored tape
placed longitudinally under the copper tape
shield

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Aluminum Interlocked Armor (AIA)

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black or as requested

CATALOG
NUMBER

Print:

•	GENERAL CABLE® 3/C SIZE (AWG OR KCMIL)
COPPER CPT TRXLPE 25 kV (100% INS LEVEL)
ACID-FLAME-CHECK ✓✓ ® CSA HL HVTECK
FT4 (-40˚C) DIR BUR SUN RES MONTH/YEAR
(LIGHTNING BOLT SYMBOL) SEQUENTIAL
LENGTH MARK

Options:

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

Applications:

•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)

Features:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend and impact tests at -40˚C

Compliances:

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
	 • CSA Standard C68.3
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided
on returnable steel reels that require a deposit.
Extra charges apply for cuts less than 1000 ft.,
lagging, pulling eyes, paralleling and plexing

NOMINAL DIAMETER (OVER)
COPPER
WEIGHT
COND. GROUND
INSULATION
INNER
ARMOR
CABLE
NO. SIZE WIRE INSULATION
SHIELD
JACKET
OF (AWG/ SIZE
LBS/ kg/
COND. kcmil) (AWG) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT km

NET WEIGHT
W/ARMOR
LBS/1000 FT
AL STEEL

AMPACITY**
kg/km
(40˚C
AL STEEL AMBIENT)

1 AWG THRU 500 kcmil—THREE CONDUCTOR—100% INS. LEVEL, 260 MILS INS. (6.60 mm)—25 kV
17496.850100*
17496.855100*
17496.855200*
17496.855300*
17496.855400*
17496.856000*
17496.856200*
17496.856500*

3

1

6

0.87 22.1 0.94

23.9

2.26

57.5

2.55

64.8

2.67 67.8

973 1448 3250

4300 4840 6390

187

3

1/0

6

0.91 23.1 0.97

24.6

2.34

59.5

2.63

66.8

2.74 69.6 1181 1758 3550

4630 5290 6890

215

3

2/0

6

0.95 24.1 1.01

25.7

2.43

61.7

2.72

69.1

2.84 72.2 1446 2152 3930

5040 5850 7500

246

3

3/0

4

0.99 25.1 1.06

26.9

2.54

64.5

2.82

71.6

2.94 74.7 1827 2719 4440

5600 6610 8340

283

3

4/0

4

1.04 26.4 1.13

28.7

2.70

68.5

2.98

75.7

3.10 78.8 2249 3347 5090

6320 7580 9410

325

3

250

4

1.10 27.9 1.18

30.1

2.87

72.9

3.16

80.3

3.29 83.6 2619 3898 5900

7220 8790 10750

359

3

350

3

1.24 31.5 1.33

33.8

3.17

80.5

3.46

87.9

3.60 91.5 3606 5366 7180

8590 10680 12780

438

3

500

3

1.32 33.5 1.41

35.8

3.34

84.9

3.63

92.2

3.76 95.5 5032 7489 8950 10480 13320 15590

536

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on ICEA Publication P 46-426 for 15 kV cables. Ampacities at other voltage levels do not vary significantly.
Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).

Phone: 888-593-3355
www.generalcable.com

SPEC 8500
October, 2012

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored	
25 kV, CSA HVTECK, 133% Ins. Level, 320 Mils, Three Conductor
Features:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend and impact tests at -40˚C

Compliances:
Product Construction:
Conductor:

Armor:

•	Aluminum Interlocked Armor (AIA)

•	1 AWG thru 350 kcmil bare copper compact
Class B strand

Strand Shield:

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Insulation:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Insulation Shield:

•	This consists of a semi-conducting thermosetting
layer, applied in a triple extrusion process, plus a
helically applied gapped copper tape
•	Color-coded: black, red or blue colored tape
placed longitudinally under the copper tape
shield

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

CATALOG
NUMBER

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black or as requested

Print:

•	GENERAL CABLE® 3/C SIZE (AWG OR KCMIL)
COPPER CPT TRXLPE 25 kV (133% INS LEVEL)
ACID-FLAME-CHECK ✓✓ ® CSA HL HVTECK
FT4 (-40˚C) DIR BUR SUN RES MONTH/YEAR
(LIGHTNING BOLT SYMBOL) SEQUENTIAL
LENGTH MARK

Options:

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

Applications:

•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
	 • CSA Standard C68.3
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

NOMINAL DIAMETER (OVER)
COPPER
COND. GROUND
WEIGHT
INSULATION
INNER
ARMOR
CABLE
NO. SIZE WIRE INSULATION
SHIELD
JACKET
OF (AWG/ SIZE
LBS/ kg/
COND. kcmil) (AWG) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT km

NET WEIGHT
W/ARMOR
AMPACITY**
LBS/1000 FT
kg/km
(40˚C
AL STEEL AL STEEL AMBIENT)

1 AWG THRU 350 kcmil—THREE CONDUCTOR—133% INS. LEVEL, 320 MILS INS. (8.13 mm)—25 kV
17496.860100*
17496.865100*
17496.865200*
17496.865300*
17496.865400*
17496.866000*
17496.866200*

3

1

6

0.99 25.2 1.06

26.9

2.53

64.2

2.82

71.6

2.94 74.7

985 1466 3690 4850

5490 7210

187

3

1/0

6

1.03 26.2 1.12

28.5

2.65

67.3

2.94

74.7

3.06 77.7 1193 1775 4110 5330

6120 7930

215

3

2/0

6

1.07 27.2 1.16

29.5

2.74

69.6

3.03

77.0

3.15 80.0 1460 2173 4490 5740

6680 8540

246

3

3/0

4

1.12 28.5 1.21

30.8

2.91

73.9

3.19

81.1

3.33 84.6 1842 2741 5270 6600

7840 9820

283

3

4/0

4

1.17 29.8 1.26

32.0

3.02

76.7

3.31

84.1

3.44 87.4 2261 3365 5840 7220

8700 10740

325

3

250

4

1.22 30.9 1.31

33.2

3.15

80.0

3.43

87.1

3.58 90.9 2629 3912 6440 7880

9590 11720

359

3

350

3

1.37 34.8 1.45

36.9

3.44

87.4

3.73

94.8

3.88 98.6 3615 5380 7720 9250 11490 13770

438

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**	Ampacity is based on ICEA Publication P 46-426 for 15 kV cables. Ampacities at other voltage levels do not vary significantly.
	 Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).

Phone: 888-593-3355
www.generalcable.com

SPEC 8525

August, 2013

HVTECK

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored	
28 kV (133% Ins. Level) / 35 kV (100% Ins. Level), 345 Mils, CSA HVTECK, Three Conductor
Product Construction:
Conductor:

•	1 AWG thru 350 kcmil bare copper compact
Class B strand

Strand Shield:

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Insulation:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Insulation Shield:

•	This consists of a semi-conducting thermosetting
layer, applied in a triple extrusion process, plus a
helically applied gapped copper tape
•	Color-coded: black, red or blue colored tape
placed longitudinally under the copper tape
shield

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Aluminum Interlocked Armor (AIA)

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black or as requested

CATALOG
NUMBER

Print:

•	GENERAL CABLE® 3/C SIZE (AWG OR KCMIL)
COPPER CPT TRXLPE 28 kV (133% INS
LEVEL) / 35 kV (100% INS LEVEL) ACID-FLAMECHECK ✓✓ ® CSA HL HVTECK FT4 (-40˚C) DIR
BUR SUN RES MONTH/YEAR (LIGHTNING BOLT
SYMBOL) SEQUENTIAL LENGTH MARK

Options:

•	Galvanized Steel Interlocked Armor (GSIA)
•	Other constructions available upon request

Applications:

•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)

Features:

•	Rated at 90˚C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost-effective alternative to installations
in conduit
•	Meets cold bend and impact tests at -40˚C

Compliances:

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
	 • CSA Standard C68.3
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

NOMINAL DIAMETER (OVER)
COPPER
WEIGHT
COND. GROUND
INSULATION
INNER
ARMOR
CABLE
NO. SIZE WIRE INSULATION
SHIELD
JACKET
OF (AWG/ SIZE
LBS/ kg/
COND. kcmil) (AWG) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT km

NET WEIGHT
W/ARMOR
LBS/1000 FT
AL

STEEL

AMPACITY**
(40˚C
STEEL AMBIENT)

kg/km
AL

1 AWG THRU 350 kcmil—THREE CONDUCTOR— 28 kV (133% INS. LEVEL) / 35 kV (100% INS. LEVEL), 345 MILS INS. (8.76 mm)
17496.890100* 3
17496.895100*
17496.895200*
17496.895300*
17496.895400*
17496.896000*
17496.896200*

1

6

1.04 26.4 1.13

28.7

2.68

68.2

2.97

75.5

3.10

78.8

988 1470 3980 5210

5930 7750

187

3

1/0

6

1.08 27.5 1.17

29.7

2.76

70.2

3.05

77.5

3.18

80.8 1200 1786 4360 5620

6490 8370

215

3

2/0

6

1.12 28.5 1.21

30.8

2.92

74.2

3.21

81.6

3.36

85.4 1466 2182 4950 6280

7370 9350

246

3

3/0

4

1.17 29.7 1.26

32.0

3.02

76.7

3.31

84.1

3.46

87.9 1848 2750 5490 6860

8160 10210

283

3

4/0

4

1.22 31.0 1.31

33.3

3.14

79.6

3.43

87.2

3.58

90.9 2264 3369 6090 7510

9060 11180

325

3

250

4

1.27 32.3 1.37

34.8

3.26

82.9

3.55

90.2

3.70

94.0 2635 3921 6660 8140

9910 12120

359

3

350

3

1.42 36.1 1.51

38.4

3.56

90.5

3.85

97.8

4.00 101.6 3621 5389 7960 9540 11840 14190

438

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**	Ampacity is based on ICEA Publication P 46-426 for 15 kV cables. Ampacities at other voltage levels do not vary significantly.
	 Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).

Phone: 888-593-3355
www.generalcable.com

SPEC 8550

September, 2013

VERTITECK TECK90
®

XLPE/PVC/GSIA/PVC, Power, Unshielded, Armored
1 kV, CSA TECK90, Three Conductor
Features (cont’d.):

•	Lighter than mine shaft cable with conventional
steel wire armor (SWA)
•	More flexible than SWA cables, resulting in easier
handling during installation
•	Terminations and connections to electrical
cabinets are similar to standard TECK90 cables
•	Meets cold bend and impact tests at -40˚C

Product Construction:
Conductor:

•	1/0 AWG thru 1000 kcmil bare copper compact
Class B strand

•	Three ground (bonding) conductors
•	Other constructions available upon request

Applications:

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp, or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands
•	Cost-effective alternative to installation
in conduit
•	Typical vertical installations include mine shafts,
tall commercial buildings, inclined tunnels and
vertical cable trays
	 (Note that the overall jacket is required for all
damp and wet locations and for all corrosive
environments: CE Code Part 1, Rules 12-708 and
22-200)

Insulation:

•	Cross-linked Polyethylene (XLPE), Type RW90
•	Color-coded: printed numbers

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Galvanized Steel Interlocked Armor (GSIA)

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), black

Features:

Print:

•	Rated at 90˚C wet or dry
•	The jacket under the armor (inner jacket) is
designed with longitudinal raised ribs. The
armor is then applied and bites into these ribs to
provide a solidly locked construction. This feature
enables the cable to be self-supporting (core will
not slip) during vertical installation when cable
weight is supported by the copper conductors

•	GENERAL CABLE ACID-FLAME-CHECK ✓✓
AG14 FT1 FT4 HL VERTITECK® GSIA XLPE
(-40˚C) 3/C SIZE (AWG OR KCMIL) 1000 V DIR
BUR SUN RES CSA MONTH-YEAR SEQUENTIAL
LENGTH MARK
®

CATALOG NUMBER

Compliances:

Options:

®

MIN. AVG.
NOMINAL DIAMETER (OVER)
COND. GROUND INSULATION
INSULATION
ARMOR
CABLE
THICKNESS
SIZE WIRE
NO. OF (AWG/ SIZE
COND. kcmil) (AWG) INCHES mm INCHES mm INCHES mm INCHES mm

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

NET WEIGHT
W/STEEL ARMOR

COPPER WEIGHT
LBS/
1000 FT

kg/km

LBS/
1000 FT

MAXIMUM
AMPACITY**
SELF(30°C
SUPPORTING
kg/km AMBIENT) LENGTH***(m)

1/0 AWG THRU 1000 kcmil—THREE CONDUCTOR—1000 V
11289.415100*

3

1/0

6

0.080

2.03

0.36

9.0 1.66

42.2

1.78

45.2

1082

1610

2520

3760

170

212

11289.415200*

3

2/0

6

0.080

2.03

0.54

13.8 1.75

44.5

1.87

47.5

1342

1997

2880

4280

195

232

11289.415300*

3

3/0

4

0.080

2.03

0.59

15.0 1.85

47.0

1.97

50.1

1719

2558

3360

5000

225

254

11289.415400*

3

4/0

4

0.080

2.03

0.64

16.3 1.96

49.8

2.08

52.9

2133

3174

4080

6080

260

260

11289.416000*

3

250

4

0.090

2.29

0.71

18.0 2.15

54.6

2.27

57.7

2498

3718

4790

7130

290

270

11289.416200*

3

350

3

0.090

2.29

0.81

20.4 2.36

60.0

2.50

63.5

2475

5171

6100

9080

350

288

11289.416500*

3

500

2

0.090

2.29

0.93

23.5 2.62

66.6

2.76

70.1

4891

7279

7900

11760

430

***

11289.417000*

3

750

2

0.090

2.29

1.10

27.9 2.99

76.0

3.13

79.5

7306

10873

10830

16110

535

***

11289.417500*

3

1000

1

0.090

2.29

1.25

31.8 3.38

85.6

3.54

89.9

9714

14456

13970

20780

615

***

Dimensions and weight are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on CE Code Part 1, Table 2 (three conductors in raceway [conduit]) and Rule 4-004.
***Maximum self-supporting lengths are based on safety factor of 5 and a tensile strength of 37,000 psi for soft drawn copper.
Higher safety factors or lower tensile strength values may be required to address more stringent safety regulations.

Phone: 888-593-3355
www.generalcable.com

SPEC 8575

September, 2013

VERTITECK TECK90
®

TRXLPE/PVC/GSIA/PVC, Power, Unshielded, Armored
5 kV, CSA TECK90, 90 Mils, Three Conductor
Product Construction:
Conductor:

•	1/0 AWG thru 500 kcmil bare copper
compact strand

Strand Shield:

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Insulation:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE), Type RW90
•	Color-coded: printed numbers

Applications (cont’d.):

Compliances:

Features:

Packaging:

•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands
•	Cost-effective alternative to installation
in conduit
•	Typical vertical installations include mine shafts,
tall commercial buildings, inclined tunnels and
vertical cable trays
	 (Note that the overall jacket is required for all
damp and wet locations and for all corrosive
environments: CE Code Part 1, Rules 12-708 and
22-200)

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Galvanized Steel Interlocked Armor (GSIA)

Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), orange

•	Rated at 90˚C wet or dry
•	The jacket under the armor (inner jacket) is
designed with longitudinal raised ribs. The
armor is then applied and bites into these ribs to
provide a solidly locked construction. This feature
enables the cable to be self-supporting (core will
not slip) during vertical installation when cable
weight is supported by the copper conductors
•	Lighter than mine shaft cable with conventional
steel wire armor (SWA)
•	More flexible than SWA cables, resulting in easier
handling during installation
•	Terminations and connections to electrical
cabinets are similar to standard TECK90 cables
•	Meets cold bend and impact tests at -40˚C

Print:

•	GENERAL CABLE® ACID-FLAME-CHECK ✓✓ ®
AG14 FT1 FT4 HL VERTITECK® GSIA TRXLPE
(-40˚C) 3/C SIZE (AWG OR KCMIL) 5000 V
DIR BUR SUN RES CSA MONTH-YEAR
SEQUENTIAL LENGTH MARK

Options:

•	Three ground (bonding) conductors
•	Other constructions available upon request

Applications:

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp, or wet locations

NOMINAL DIAMETER (OVER)

CATALOG NUMBER

NO. OF
COND.

COND.
SIZE
(AWG/
kcmil)

GROUND
WIRE
SIZE
(AWG)

INSULATION
INCHES

mm

ARMOR
INCHES

mm

CABLE
INCHES

mm

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable
•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

COPPER WEIGHT
LBS/
1000 FT

kg/km

NET WEIGHT
W/STEEL ARMOR
LBS/
1000 FT

MAXIMUM
AMPACITY**
SELF(30°C
SUPPORTING
kg/km AMBIENT) LENGTH***(m)

1/0 AWG THRU 500 kcmil—THREE CONDUCTOR—UNSHIELDED, 90 MILS INS. (2.29 mm)—5 kV
17497.055100*

3

1/0

6

0.56

14.2

1.77

45.0

1.87

47.5

1082

1610

2700

4020

170

200

17497.055200*

3

2/0

6

0.60

15.2

1.86

47.3

1.96

49.8

1343

1999

3060

4550

195

221

17497.055300*

3

3/0

4

0.65

16.4

1.97

50.0

2.07

52.6

1720

2560

3550

5280

225

240

17497.055400*

3

4/0

4

0.70

17.8

2.08

52.9

2.18

55.4

2315

3445

4290

6380

260

249

17497.056000*

3

250

4

0.75

19.1

2.25

57.2

2.35

59.7

2469

3674

4990

7430

290

251

17497.056200*

3

350

3

0.85

21.8

2.46

62.5

2.59

65.8

3476

5173

6340

9430

350

278

17497.056500*

3

500

2

0.98

24.9

2.72

69.1

2.85

72.4

4837

7198

8130

12100

430

230

Dimensions and weight are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Ampacity is based on CE Code Part 1, Table 2 (three conductors in raceway [conduit]) and Rule 4-004.
***Maximum self-supporting lengths are based on safety factor of 5 and a tensile strength of 37,000 psi for soft drawn copper. Higher safety factors or lower tensile strength values may be required to address more
stringent safety regulations.

Phone: 888-593-3355
www.generalcable.com

SPEC 8600

October, 2012

VERTITECK HVTECK
®

TRXLPE/Tape Shield/PVC/GSIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 133% Ins. Level, 220 Mils, Three Conductor
Features:

Product Construction:
Conductor:

•	Rated at 90˚C wet or dry
•	The jacket under the armor (inner jacket) is
designed with longitudinal raised ribs. The
armor is then applied and bites into these ribs to
provide a solidly locked construction. This feature
enables the cable to be self-supporting (core will
not slip) during vertical installation when cable
weight is supported by the copper conductors
•	Lighter than mine shaft cable with conventional
steel wire armor (SWA)
•	More flexible than SWA cables, resulting in easier
handling during installation
•	Terminations and connections to electrical
cabinets are similar to standard TECK90 cables
•	Meets cold bend and impact tests at -40˚C

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), red

•	2 AWG thru 750 kcmil bare copper compact
Class B strand

Print:

Strand Shield:

•	GENERAL CABLE® ACID-FLAME-CHECK ✓✓ ®
AG 14 FT1 FT4 HL VERTITECK® GSIA TRXLPE
(-40˚C) 3/C SIZE (AWG OR KCMIL) 15,000 V
DIR BUR SUN RES CSA MONTH-YEAR SEQUENTIAL PRINT

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Insulation:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Compliances:

Options:

Insulation Shield:

•	Three ground (bonding) conductors

•	This consists of a semi-conducting thermosetting
layer, applied in a triple extrusion process, plus a
helically applied gapped copper tape
•	Color code: black, red, or blue colored tape
placed longitudinally under the copper tape
shield

Applications:

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands
•	Cost-effective alternative to installation
in conduit
•	Typical vertical installations include mine shafts,
tall commercial buildings, inclined tunnels and
vertical cable trays
	 (Note that the overall jacket is required for all
damp and wet locations and for all corrosive
environments: CE Code Part 1, Rules 12-708 and
22-200)

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Galvanized Steel Interlocked Armor (GSIA)

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
	 • CSA Standard C68.3
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

NOMINAL DIAMETER (OVER)
NO.
OF
COND.

CATALOG
NUMBER

COND.
SIZE
(AWG/
kcmil)

GROUND INSULATION
WIRE
SIZE
(AWG) INCHES mm

INSULATION SHIELD
INCHES

mm

ARMOR
INCHES

mm

CABLE
INCHES

mm

COPPER WEIGHT
LBS/
1000 FT

kg/km

NET WEIGHT
LBS/
1000 FT

kg/km

MAXIMUM
SELFSUPPORTING
LENGTH**
(M)

2 AWG THRU 750 kcmil—THREE CONDUCTOR—133% INS. LEVEL, 220 MILS INS. (5.59 mm)—15 kV
17497.540200*

3

2

6

0.76

19.3

0.82

20.8

2.50

63.5

2.66

67.6

862

1283

4138

6157

85

17497.540100*

3

1

6

0.79

20.1

0.85

21.6

2.57

65.3

2.73

69.3

1034

1539

4424

6583

100

17497.545100*

3

1/0

6

0.83

21.1

0.89

22.6

2.65

67.3

2.81

71.4

1245

1853

4765

7090

118

17497.545200*

3

2/0

6

0.87

22.1

0.93

23.6

2.74

69.6

2.90

73.7

1513

2251

5181

7709

137

17497.545300*

3

3/0

4

0.92

23.4

0.98

24.9

2.84

72.1

3.00

76.2

1899

2826

5757

8566

155

17497.545400*

3

4/0

4

0.97

24.6

1.03

26.2

2.95

74.9

3.12

79.2

2321

3454

6392

9511

176

17497.546000*

3

250

4

1.01

25.7

1.09

27.7

3.08

78.2

3.27

83.1

2697

4013

7096

10559

188

17497.546200*

3

350

3

1.12

28.4

1.18

30.0

3.36

85.3

3.54

89.9

3692

5494

8674

12907

215

17497.546500*

3

500

3

1.23

31.2

1.30

33.0

3.62

91.9

3.80

96.5

5218

7764

10646

15841

250

17497.547000*

3

750

2

1.41

35.8

1.48

37.6

4.00

101.6

4.19

106.4

8124

12089

14417

21452

277

Dimensions and weights are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Maximum self-supporting lengths are based on safety factor of 5 and a tensile strength of 37,000 psi for soft drawn copper. Higher safety factors or lower tensile strength values may be required to address more
	 stringent safety regulations.

Phone: 888-593-3355
www.generalcable.com

SPEC 8625

October, 2012

VERTITECK HVTECK
®

TRXLPE/Tape Shield/PVC/GSIA/PVC, Power, Shielded, Armored
15 kV, CSA HVTECK, 100% Ins. Level, 175 Mils, Three Conductor
Product Construction:
Conductor:

•	2 AWG thru 750 kcmil bare copper compact
Class B strand

Strand Shield:

•	A thermoset semi-conducting strand shield is
extruded over the conductor

Insulation:

Applications:

•	Tree-Retardant Cross-linked Polyethylene
(TRXLPE)

Insulation Shield:

•	This consists of a semi-conducting thermosetting
layer, applied in a triple extrusion process, plus a
helically applied gapped copper tape
•	Color code: black, red, or blue colored tape
placed longitudinally under the copper tape
shield

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare copper conductor

Inner Jacket:

•	Lead-free, flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

•	Galvanized Steel Interlocked Armor (GSIA)

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands
•	Cost-effective alternative to installation
in conduit
•	Typical vertical installations include mine shafts,
tall commercial buildings, inclined tunnels and
vertical cable trays
	 (Note that the overall jacket is required for all
damp and wet locations and for all corrosive
environments: CE Code Part 1, Rules 12-708 and
22-200)

Features:

Overall Jacket:

•	Lead-free, ACID-FLAME-CHECK ✓✓ ® flameretardant, moisture- and sunlight-resistant
Polyvinyl Chloride (PVC), red

Print:

•	GENERAL CABLE® ACID-FLAME-CHECK ✓✓ ®
AG 14 FT1 FT4 HL VERTITECK® GSIA TRXLPE
(-40˚C) 3/C SIZE (AWG OR KCMIL) 15,000 V
DIR BUR SUN RES CSA MONTH-YEAR
SEQUENTIAL LENGTH MARK

Options:

•	Rated at 90˚C wet or dry
•	The jacket under the armor (inner jacket) is
designed with longitudinal raised ribs. The
armor is then applied and bites into these ribs to
provide a solidly locked construction. This feature
enables the cable to be self-supporting (core will
not slip) during vertical installation when cable
weight is supported by the copper conductors
•	Lighter than mine shaft cable with conventional
steel wire armor (SWA)
•	More flexible than SWA cables, resulting in easier
handling during installation

•	Three ground (bonding) conductors

Features (cont’d.):

•	Terminations and connections to electrical
cabinets are similar to standard TECK90 cables
•	Meets cold bend and impact tests at -40˚C

Compliances:

Industry Compliances:
	 • CSA Standard C22.2 No. 131 and No. 174
	 • CSA Standard C68.3
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
	 • ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

Packaging:

•	For Canadian customers, lengths are provided
on returnable wood or steel reels that require a
deposit. Extra charges apply for lagging, pulling
eyes, paralleling and plexing
•	For U.S. customers, material cut to length and
shipped on non-returnable wood reels, while
lengths in excess of 10,000 lbs. are provided on
returnable steel reels that require a deposit. Extra
charges apply for cuts less than 1000 ft., lagging,
pulling eyes, paralleling and plexing

NOMINAL DIAMETER (OVER)
COND. GROUND
INSULATION
NO.
SIZE
WIRE
OF
(AWG/
SIZE
COND. kcmil) (AWG) INCHES mm

CATALOG
NUMBER

INSULATION SHIELD
INCHES

mm

ARMOR
INCHES

mm

CABLE
INCHES

mm

COPPER WEIGHT
LBS/
1000 FT

kg/km

MAXIMUM
SELFSUPPORTING
LENGTH**
(M)
kg/km

NET WEIGHT
LBS/
1000 FT

2 AWG THRU 750 kcmil—THREE CONDUCTOR—100% INS. LEVEL, 175 MILS INS. (4.45 mm)—15 kV
17497.440200*

3

2

6

0.67

17.0

0.72

18.3

2.30

58.4

2.46

62.5

845

1257

3761

5596

94

17497.440100*

3

1

6

0.70

17.8

0.76

19.3

2.37

60.2

2.53

64.3

1017

1513

4022

5985

110

17497.445100*

3

1/0

6

0.74

18.8

0.80

20.3

2.46

62.5

2.61

66.3

1229

1829

4385

6525

128

17497.445200*

3

2/0

6

0.78

19.8

0.84

21.3

2.55

64.8

2.71

68.8

1497

2228

4800

7142

147

17497.445300*

3

3/0

4

0.83

21.1

0.89

22.6

2.67

67.8

2.83

71.9

1882

2800

5354

7967

166

17497.445400*

3

4/0

4

0.88

22.4

0.94

23.9

2.79

70.9

2.95

74.9

2304

3428

5979

8897

188

17497.446000*

3

250

4

0.92

23.4

0.98

24.9

2.89

73.4

3.05

77.5

2677

3983

6518

9699

204

17497.446200*

3

350

3

1.02

25.9

1.09

27.7

3.15

80.0

3.33

84.6

3675

5468

8043

11968

231

17497.446500*

3

500

3

1.14

29.0

1.21

30.7

3.47

88.1

3.66

93.0

5111

7605

10132

15076

262

17497.447000*

3

750

2

1.32

33.5

1.39

35.3

3.86

98.0

4.04

102.6

7555

11242

13403

19944

298

Dimensions and weight are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Maximum self-supporting lengths are based on safety factor of 5 and a tensile strength of 37,000 psi for soft drawn copper. Higher safety factors or lower tensile strength values may be required to address more
stringent safety regulations.

Phone: 888-593-3355
www.generalcable.com

SPEC 8700

March, 2012

ACWU

XLPE/AIA/PVC, Control, Armored
600 V, CSA ACWU90 (-40°C), Single Conductor
Compliances:

Product Construction:
Conductor:

Print:

•	4/0 AWG thru 1000 kcmil bare ACM aluminum
(8000 series aluminum) compact Class B strand

Insulation:

•	Cross-linked Polyethylene (XLPE), Type RW90
•	Color-coded: black, marked “SR”

Ground (Bonding) Conductor:

•	The conductor is a concentric serving of solid
bare aluminum (ACM) wires applied over the
insulation

Armor:

•	Aluminum Interlocked Armor (AIA)

Jacket:

COND.
NO.
SIZE
OF
(AWG/
COND. kcmil)

•	GENERAL CABLE® MI ACID-FLAMECHECK ✓✓ ® AG14 FT4 HL ACWU90 XLPE
(-40°C) 1/C SIZE (AWG OR KCMIL) AL 600 V
DIR BUR SUN RES CSA MONTH-YEAR
SEQUENTIAL LENGTH MARK

Packaging:

•	For Canadian customers, nominal standard
lengths are provided on returnable wood or steel
reels that require a deposit. Extra charges apply
for cut to length, lagging, pulling eyes, paralleling
and plexing
Note: Not for sale in the U.S.

Applications:

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For service entrance installations

Features:

•	ACID-FLAME-CHECK ✓✓ ® flame-retardant,
moisture- and sunlight-resistant Polyvinyl
Chloride (PVC), black

CATALOG NUMBER

Industry Compliances:
	 • CSA Standard C22.2 No. 51 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

•	Rated at 90°C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost-effective alternative to installations in
conduit
•	Meets cold bend and impact tests at -40°C

MIN. AVG.
INSULATION
GROUND
THICKNESS
WIRE
SIZE
(AWG) INCHES mm

NOMINAL DIAMETER (OVER)
INSULATION
INCHES

mm

ARMOR
INCHES

mm

CABLE
INCHES

mm

ALUMINUM
WEIGHT**

NET
WEIGHT

LBS/
LBS/
AMPACITY***
1000 FT kg/km 1000 FT kg/km (30°C AMBIENT)

4/0 AWG THRU 1000 kcmil—ONE CONDUCTOR—600 V
11281.015400

1

4/0

2

0.055

1.40

0.591

15.01

0.940

23.88

1.036

26.31

260

387

504

750

315

11281.016000

1

250

1

0.065

1.65

0.658

16.71

1.007

25.58

1.103

28.02

312

464

600

893

355

11281.016200

1

350

1/0

0.065

1.65

0.754

19.15

1.103

28.02

1.199

30.45

423

630

745

1107

445

11281.016500

1

500

2/0

0.065

1.65

0.872

22.15

1.221

31.01

1.317

33.45

594

884

952

1417

545

11281.016700

1

600

2/0

0.080

2.03

0.985

25.02

1.334

33.88

1.430

36.32

686

1021

1099

1635

690

11281.017000

1

750

3/0

0.080

2.03

1.080

27.43

1.429

36.30

1.525

38.74

848

1262

1305

1942

785

11281.017500

1

1000

3/0

0.080

2.03

1.230

31.42

1.667

42.34

1.779

45.19

1093

1627

1704

2536

845

Dimensions and weight are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Conductor and ground weight.
***Ampacity is based on CE Code Part 1, Table 3 (single conductor in free air) and Rule 4-004.

Phone: 888-593-3355
www.generalcable.com

SPEC 8750

March, 2012

ACWU

XLPE/AIA/PVC, Control, Armored
600 V, CSA ACWU90 (-40°C), Three Conductor
Product Construction:
Conductor:

•	6 AWG thru 750 kcmil bare ACM aluminum (8000
series aluminum) compact Class B strand

Insulation:

•	Cross-linked Polyethylene (XLPE), Type RW90
•	Color-coded: 4 AWG to 2 AWG—black, white
and red; 1/0 AWG to 750 kcmil—per ICEA
Method 4, individual conductors colored black
with conductor number surface printed in
contrasting ink

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare aluminum (ACM) conductor

Armor:

•	Aluminum Interlocked Armor (AIA)

Jacket:

Print:

•	GENERAL CABLE® MI ACID-FLAME-CHECK ✓✓ ®
AG14 FT4 HL ACWU90 XLPE (-40°C)3/C
SIZE (AWG OR KCMIL) AL 600 V DIR BUR
SUN RES CSA MONTH-YEAR SEQUENTIAL
LENGTH MARK

CATALOG NUMBER

Compliances:

Industry Compliances:
	 • CSA Standard C22.2 No. 51 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For service entrance installations

Features:

•	ACID-FLAME-CHECK ✓✓ ® flame-retardant,
moisture- and sunlight-resistant Polyvinyl
Chloride (PVC), black

COND.
NO.
SIZE
OF
(AWG/
COND. kcmil)

Applications:

•	Rated at 90°C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost-effective alternative to installations in
conduit
•	Meets cold bend and impact tests at -40°C

MIN. AVG.
INSULATION
GROUND
THICKNESS
WIRE
SIZE
(AWG) INCHES mm

Packaging:

•	For Canadian customers, nominal standard
lengths are provided on returnable wood or steel
reels that require a deposit. Extra charges apply
for cut to length, lagging and pulling eyes
Note: Not for sale in the U.S.

NOMINAL DIAMETER (OVER)
INSULATION
INCHES

mm

ARMOR
INCHES

mm

CABLE
INCHES

mm

ALUMINUM
WEIGHT*

NET
WEIGHT

LBS/
LBS/
1000 FT kg/km 1000 FT kg/km

AMPACITY**
(30°C
AMBIENT)

6 AWG THRU 750 kcmil—THREE CONDUCTOR—600 V
11281.030600

3

6

8

0.045

1.14

0.266

6.76

0.783

19.89

0.879

22.33

92

137

325

484

55

11281.030400

3

4

6

0.045

1.14

0.310

7.87

0.918

23.32

1.014

25.76

145

216

441

657

75

11281.030200

3

2

6

0.045

1.14

0.365

9.27

1.044

26.52

1.140

28.96

212

316

564

840

100

11281.030100

3

1

4

0.045

1.14

0.418

10.62

1.165

29.59

1.261

32.03

275

409

677

1008

115

11281.035100

3

1/0

4

0.055

1.40

0.456

11.58

1.252

31.80

1.348

34.24

336

500

783

1166

135

11281.035200

3

2/0

4

0.055

1.40

0.496

12.60

1.343

34.11

1.439

36.55

414

616

897

1336

150

11281.035300

3

3/0

4

0.055

1.40

0.543

13.79

1.450

36.83

1.546

39.27

512

762

1047

1559

175

11281.035400

3

4/0

4

0.055

1.40

0.593

15.06

1.565

39.75

1.661

42.19

636

947

1215

1809

205

11281.036000

3

250

2

0.065

1.65

0.662

16.81

1.812

46.02

1.924

48.87

770

1146

1551

2309

230

11281.036200

3

350

2

0.065

1.65

0.757

19.23

2.029

51.54

2.141

54.38

1050

1563

1951

2905

280

11281.036500

3

500

1

0.065

1.65

0.878

22.30

2.306

58.57

2.418

61.42

1494

2224

2562

3815

350

11281.036700

3

600

1

0.080

2.03

0.984

24.99

2.424

61.57

2.563

65.10

1791

2667

3035

4519

385

11281.037000

3

750

1/0

0.080

2.03

1.077

27.36

2.706

68.73

2.902

73.71

2221

3307

3703

5513

435

Dimensions and weight are nominal; subject to industry tolerances.
*Conductor and ground weight.
**Ampacity is based on CE Code Part 1, Table 4 (three conductors in raceway [conduit]) and Rule 4-004.

Phone: 888-593-3355
www.generalcable.com

SPEC 8775

March, 2012

ACWU

XLPE/AIA/PVC, Control, Armored
600 V, CSA ACWU90 (-40°C), Four Conductor
Compliances:

Product Construction:
Conductor:

Print:

•	2 AWG thru 750 kcmil bare ACM aluminum (8000
series aluminum) compact Class B strand

Insulation:

•	Cross-linked Polyethylene (XLPE), Type RW90
•	Color-coded: 2 AWG—black, white and red;
1 AWG to 750 kcmil—per ICEA Method 4,
individual conductors colored black with
conductor number surface printed in
contrasting ink

Ground (Bonding) Conductor:

•	The conductor consists of one uninsulated
stranded bare aluminum (ACM) conductor

Armor:

Packaging:

•	For Canadian customers, nominal standard
lengths are provided on returnable wood or steel
reels that require a deposit. Extra charges apply
for cut lengths, lagging and pulling eyes

Applications:

•	For exposed and concealed wiring in dry, damp
or wet locations
•	For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
•	For direct earth burial (with protection as required
by inspection authority)
•	For wiring in all hazardous locations when used
with certified HL cable glands
•	For service entrance installations

Note: Not for sale in the U.S.

•	Rated at 90°C wet or dry
•	Excellent crush, oil and chemical resistance
•	Provides long service life
•	Cost-effective alternative to installations in
conduit
•	Meets cold bend and impact tests at -40°C

•	ACID-FLAME-CHECK ✓✓ ® flame-retardant,
moisture- and sunlight-resistant Polyvinyl
Chloride (PVC), black

COND.
NO.
SIZE
OF
(AWG/
COND. kcmil)

•	GENERAL CABLE® MI ACID-FLAME-CHECK
✓✓ ® AG14 FT4 HL ACWU90 XLPE (-40°C) 4/C
SIZE (AWG OR KCMIL) AL 600 V DIR BUR SUN
RES CSA MONTH-YEAR SEQUENTIAL LENGTH
MARK

Features:

•	Aluminum Interlocked Armor (AIA)

Jacket:

CATALOG NUMBER

Industry Compliances:
	 • CSA Standard C22.2 No. 51 and No. 174
Flame Test Compliances:
	 • CSA FT1 and FT4
	 • IEEE 383 (70,000 BTU/hr)
	 • UL 1581 (70,000 BTU/hr)
	 • IEEE 1202 (70,000 BTU/hr) CSA FT4
	 • ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
	 • Hazardous Location Rating: HL
	 • EPA 40 CFR, Part 261 for leachable lead
content per TCLP method
	 • OSHA Acceptable

MIN. AVG.
INSULATION
GROUND
THICKNESS
WIRE
SIZE
(AWG) INCHES mm

NOMINAL DIAMETER (OVER)
INSULATION
INCHES

mm

ARMOR
INCHES

mm

ALUMINUM
WEIGHT**

CABLE
INCHES

mm

NET WEIGHT

LBS/
LBS/
1000 FT kg/km 1000 FT kg/km

AMPACITY***
(30°C
AMBIENT)

2 AWG THRU 750 kcmil—FOUR CONDUCTOR—600 V
11281.040200

4

2

6

0.045

1.14

0.365

9.27

1.091

27.71

1.187

30.15

275

410

634

943

100

11281.040100

4

1

4

0.055

1.40

0.418

10.62

1.219

30.96

1.315

33.40

364

542

772

1149

115

11281.045100

4

1/0

4

0.055

1.40

0.456

11.58

1.311

33.30

1.407

35.74

435

648

869

1323

135

11281.045200

4

2/0

4

0.055

1.40

0.496

12.60

1.407

35.74

1.503

38.18

540

804

1037

1543

150

11281.045300

4

3/0

4

0.055

1.40

0.543

13.79

1.611

40.92

1.723

43.76

671

998

1337

1990

175

11281.045400

4

4/0

4

0.055

1.40

0.593

15.06

1.732

43.99

1.844

46.84

835

1243

1556

2316

205

11281.046000

4

250

2

0.065

1.65

0.662

16.81

1.898

48.21

2.010

51.05

1006

1497

1836

2732

230

11281.046200

4

350

2

0.065

1.65

0.757

19.23

2.127

54.03

2.239

56.87

1379

2052

2335

3475

280

11281.046500

4

500

1

0.065

1.65

0.878

22.30

2.419

61.44

2.561

65.05

1966

2925

3165

4710

350

11281.046700*

4

600

1

0.080

2.03

0.984

24.99

2.678

68.02

2.817

71.55

2362

3515

3773

5615

385

11281.047000

4

750

1/0

0.080

2.03

1.077

27.36

2.900

73.66

3.042

77.27

2929

4358

4482

6670

435

Dimensions and weight are nominal; subject to industry tolerances.
*Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
**Conductor and ground weight.
***Ampacity is based on CE Code Part 1, Table 4 (three conductors in raceway [conduit]) and Rule 4-004.
	 Ampacity of 4 conductor cable is based on 3 current-carrying conductors and 1 neutral.

Phone: 888-593-3355
www.generalcable.com

Date of Issue 06/13
Section 9		

Industrial Cables

300 V – 35 kV CCW® Armored Cables
for Hazardous Locations
SPECIFICATION NO.

PRODUCT DESCRIPTION

REVISION DATE

9025

CCW
Armor

Thermocouple Extension, Single Pair, Overall Shield (OS)
UL Type ITC-HL/PLTC, PVC, 105°C, ABS CWCMC

Apr. 2011

9050

CCW®
Armor

Thermocouple Extension, Pairs, Overall Shield (OS)
UL Type ITC-HL/PLTC, PVC, 105°C, ABS CWCMC

Apr. 2011

9075

CCW®
Armor

Thermocouple Extension, Pairs, Individual and Overall Shield (IS-OS)
UL Type ITC-HL/PLTC, PVC, 105°C, ABS CWCMC

Apr. 2011

9125

CCW®
Armor

300 V Instrumentation, Pairs/Triads, Overall Shield (OS)
UL Type ITC-HL/PLTC, XLPE, 90°C, ABS CWCMC

Apr. 2011

9150

CCW®
Armor

300 V Instrumentation, Pairs/Triads, Individual and Overall Shield (IS-OS)
UL Type ITC-HL/PLTC, XLPE, 90°C, ABS CWCMC

Apr. 2011

9225

CCW®
Armor

300 V Instrumentation, Pairs/Triads, Overall Shield (OS)
UL Type ITC-HL/PLTC, PVC, 105°C, ABS CWCMC

Apr. 2011

9250

CCW®
Armor

300 V Instrumentation, Pairs/Triads, Individual and Overall Shield (IS-OS)
UL Type ITC-HL/PLTC, PVC, 105°C, ABS CWCMC

Apr. 2011

9325

CCW®
Armor

600 V Instrumentation, Pairs/Triads, Overall Shield (OS)
UL Type MC-HL, PVC/Nylon, 90°C, ABS CWCMC

Feb. 2011

9350

CCW®
Armor

600 V Instrumentation, Pairs/Triads, Individual and Overall Shield (IS-OS)
UL Type MC-HL, PVC/Nylon, 90°C, ABS CWCMC

Feb. 2011

9500

CCW®
Armor

600 V Control With Grounding Conductor
UL Type MC-HL, XLPE, 90°C, ABS CWCMC

Feb. 2011

9510

CCW®
Armor

600 V Control With Bare Grounding Conductor
UL Type MC-HL, XLPE, 90°C, ABS CWCMC

Feb. 2011

9525

CCW®
Armor

600 V Control Without Grounding Conductor
UL Type MC, XLPE, 90°C, ABS CWCMC

Feb. 2011

9600

CCW®
Armor

600 V Power, 3/C VFD and 4/C
UL Type MC-HL, XLPE, 90°C, ABS CWCMC

Feb. 2011

9615

CCW®
Armor

2000 V Power, 3/C VFD
UL Type MC-HL, XLPE, 90°C, ABS CWCMC

Feb. 2011

9625

CCW®
Armor

600 V Composite Power and Control
UL Type MC-HL, XLPE, 90°C, ABS CWCMC

Jan. 2011

9650

CCW®
Armor

600 V Composite Power and Control Without Ground
UL Type MC, XLPE, 90°C, ABS CWCMC

Feb. 2011

®

Phone: 888-593-3355
www.generalcable.com

		
Industrial Cables		

Date of Issue 06/13
Section 9

300 V – 35 kV CCW® Armored Cables
for Hazardous Locations
SPECIFICATION NO.

PRODUCT DESCRIPTION

REVISION DATE

9675

CCW
Armor

1000 V Power, 3/C VFD
CSA Type RA90, HL, XLPE, 90°C

Mar. 2012

9700

CCW®
Armor

2.4 kV Power, Nonshielded, 3/C VFD
UL Type MC-HL or MV-90, EPR, 90°C, ABS CWCMC

Feb. 2011

9800

CCW®
Armor

5 kV 133%/8 kV 100% Power, Shielded, 3/C VFD
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC

May 2012

9815

CCW®
Armor

8 kV 133% Power, Shielded, 3/C VFD
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC

May 2012

9825

CCW®
Armor

15 kV 100% Power, Shielded, 3/C
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC

May 2012

9835

CCW®
Armor

15 kV 133% Power, Shielded, 3/C
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC

May 2012

9845

CCW®
Armor

25 kV 100% Power, Shielded, 3/C
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC

May 2012

9855

CCW®
Armor

25 kV 133%/35 kV 100% Power, Shielded, 3/C
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC

Feb. 2011

9875

CCW®
Armor

35 kV 133% Power, Shielded, 3/C
UL Type MC-HL or MV-105, EPR, 105°C, ABS CWCMC

Feb. 2011

9900

CCW®
Armor

CCW® Armored Cable Tool Kit

Jan. 2010

®

Phone: 888-593-3355
www.generalcable.com

SPEC 9025

April, 2011

CCW Armored Thermocouple, Single Pair, Overall Shield
®

UL Type ITC-HL/PLTC, PVC, 105°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	16 AWG solid alloy wire per ANSI
MC 96.1
Insulation:
•	Flame-retardant Polyvinyl Chloride
(PVC), rated 105°C per UL Standards
13 and 2250
•	Color-coded per ANSI
Pair Assembly:
•	Insulated conductors are cabled
together with a left-hand lay
Overall Shield:
•	Flexfoil® aluminum/polyester tape
shield providing 100% coverage
•	Stranded tinned copper drain wire,
same size as insulated conductors
Inner Jacket:
•	Flame-retardant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250,
black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C
•	Nylon rip cord to facilitate jacket
removal
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569
•	CCW armor conductivity meets the
grounding requirements of NEC
Article 250

Phone: 888-593-3355
www.generalcable.com

Overall Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250
•	ANSI color-coded
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored Thermocouple
Extension cables provide superior
protection and reliability against
physical damage for use in
instrumentation and process control
applications requiring ITC-HL or PLTC
wiring methods
•	For use as Power Limited Tray Cable
on circuits rated 150 V or less and
5 amps or less in Class 2 or Class 3
circuits in accordance with NEC Article
725
•	For use as Instrumentation Tray Cable
on circuits rated 150 V or less and
5 amps or less in accordance with
NEC Article 727
•	Recognized for use in Class I, II, and
III, Divisions 1 and 2; or Class I, Zones
1 and 2 hazardous locations per NEC
Articles 501, 502, 503, and 505
•	Installed indoors or outdoors, in wet or
dry locations, in a raceway, as aerial
cable on a messenger, in cable trays,
or for direct burial
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides superior
mechanical protection and an
impervious barrier to moisture, gas
and liquids
•	CCW armor provides EMI shielding
performance
•	Meets cold impact at -40°C

Specifications:
Design Adherence:
•	UL 13 Power-Limited Circuit Cables
•	UL 2250 Instrumentation Tray Cable
•	UL 1569 Metal Clad Cables
•	UL 1309/CSA C22.2 No. 245 Marine
Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type PLTC, SUN RES, DIR BUR,
-40°C, UL File # E36118
•	UL Type ITC-HL, UL File # E177408
•	UL Listed Marine Shipboard, UL File
# E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9025

April, 2011

CCW Armored Thermocouple, Single Pair, Overall Shield
®

UL Type ITC-HL/PLTC, PVC, 105°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
WIRE TYPE/
SIZE
NO. OF
(AWG)
PAIRS

CATALOG
NUMBER

INSULATION
THICKNESS
mils
mm

INNER JACKET
NOMINAL
THICKNESS
CORE O.D.
mils
mm INCHES mm

NOMINAL
ARMOR O.D.
INCHES mm

JACKET
THICKNESS
mils
mm

CROSSNOMINAL
SECTIONAL APPROXIMATE NET
OVERALL O.D.
AREA¹
WEIGHT
INCHES mm
SQ. IN. LBS/1000 FT kg/1000 m

9025.16010001 EX / 16

1

15

0.38

35

0.89

0.25

6.4

0.45

11.4

50

1.27

0.56

14.2

0.25

132

196

9025.16010002

JX / 16

1

15

0.38

35

0.89

0.25

6.4

0.45

11.4

50

1.27

0.56

14.2

0.25

132

196

9025.16010003 KX / 16

1

15

0.38

35

0.89

0.25

6.4

0.45

11.4

50

1.27

0.56

14.2

0.25

132

196

9025.16010004 TX / 16

1

15

0.38

35

0.89

0.25

6.4

0.45

11.4

50

1.27

0.56

14.2

0.25

132

196

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC® Section 392.22.

COND.
TYPE
EX

ANSI MC 96.1 CONDUCTOR ALLOY AND COLOR CODE
POSITIVE WIRE
NEGATIVE WIRE
ALLOY
COLOR
ALLOY
COLOR
Chromel
Purple
Constantan
Red

JX

Iron

White

KX

Chromel

TX

Copper

OUTER
JACKET
Purple

NOM. LOOP
RESISTANCE PER
TEMP. RANGE
LIMITS OF ERROR 100 FT @ 20°C
0°C To +200°C
+/- 1.7°C
27.8 Ohms
0°C To +200°C

+/- 2.2°C

13.9 Ohms

0°C To +200°C

+/- 2.2°C

23.6 Ohms

-60°C To +100°C

+/- 1.0°C

12.0 Ohms

Constantan

Red

Black

Yellow

Alumel

Red

Yellow

Blue

Constantan

Red

Blue

Phone: 888-593-3355
www.generalcable.com

SPEC 9050

April, 2011

CCW Armored Thermocouple, Pairs, Overall Shield
®

UL Type ITC-HL/PLTC, PVC, 105°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	20 AWG solid alloy wire per ANSI MC
96.1
Insulation:
•	Flame-retardant Polyvinyl Chloride
(PVC), rated 105°C per UL Standards
13 and 2250
•	Color-coded per ANSI with one
conductor in each pair printed
alphanumerically for easy identification
Cable Assembly:
•	Individual pairs and communication
wire are cabled together with a lefthand lay
•	Communication wire: 22 AWG solid
bare copper, flame-retardant Polyvinyl
Chloride (PVC), rated 105°C, orange
Overall Shield:
•	Flexfoil® aluminum/polyester tape
shield providing 100% coverage
•	Stranded tinned copper drain wire,
same size as insulated conductors
Inner Jacket:
•	Flame-retardant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250
•	ANSI color-coded
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C
•	Nylon rip cord to facilitate jacket
removal
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569
•	CCW armor conductivity meets the
grounding requierments of NEC
Article 250

Phone: 888-593-3355
www.generalcable.com

Overall Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250
•	ANSI color-coded
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored Thermocouple
Extension cables provide superior
protection and reliability against
physical damage for use in
instrumentation and process control
applications requiring ITC-HL or PLTC
wiring methods
•	For use as Power Limited Tray Cable
on circuits rated 150 V or less and
5 amps or less in Class 2 or Class 3
circuits in accordance with NEC
Article 725
•	For use as Instrumentation Tray Cable
on circuits rated 150 V or less and
5 amps or less in accordance with
NEC Article 727
•	Recognized for use in Class I, II, and
III, Divisions 1 and 2; or Class I, Zones
1 and 2 hazardous locations per NEC
Articles 501, 502, 503, and 505
•	Installed indoors or outdoors, in wet or
dry locations, in a raceway, as aerial
cable on a messenger, in cable trays,
or for direct burial
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides superior
mechanical protection and an
impervious barrier to moisture, gas
and liquids
•	CCW armor provides EMI shielding
performance
•	Meets cold impact at -40°C

Specifications:
Design Adherence:
•	UL 13 Power-Limited Circuit Cables
•	UL 2250 Instrumentation Tray Cable
•	UL 1569 Metal Clad Cables
•	UL 1309/CSA C22.2 No. 245 Marine
Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
• IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type PLTC, SUN RES, DIR BUR,
-40°C, UL File # E36118
•	UL Type ITC-HL, UL File # E177408
•	UL Listed Marine Shipboard, UL File
# E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9050

April, 2011

CCW Armored Thermocouple, Pairs, Overall Shield
®

UL Type ITC-HL/PLTC, PVC, 105°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
CATALOG
NUMBER
9050.20041221
9050.20081221
9050.20101221
9050.20121221
9050.20161221
9050.20201221
9050.20241221
9050.20361221
9050.20501221
9050.20041222
9050.20081222
9050.20101222
9050.20121222
9050.20161222
9050.20201222
9050.20241222
9050.20361222
9050.20501222
9050.20041223
9050.20081223
9050.20101223
9050.20121223
9050.20161223
9050.20201223
9050.20241223
9050.20361223
9050.20501223
9050.20041224
9050.20081224
9050.20101224
9050.20121224
9050.20161224
9050.20201224
9050.20241224
9050.20361224
9050.20501224

CROSSCOMMUNICATION WIRE
WIRE
INSULATION
INNER JACKET NOMINAL
NOMINAL
JACKET
NOMINAL SECTIONAL
APPROXIMATE
TYPE/ NO. THICKNESS SIZE INS. THICKNESS THICKNESS
CORE O.D. ARMOR O.D. THICKNESS OVERALL O.D. AREA¹
NET WEIGHT
SIZE
OF
mm
mils mm INCHES mm INCHES mm mils mm INCHES mm
SQ. IN. LBS/1000 FT kg/1000 m
(AWG) PAIRS mils mm AWG mils
20 AWG TYPE EX MULTIPLE PAIRS OVERALL SHIELDED THERMOCOUPLE EXTENSION CABLE
EX / 20 4 15 0.38 22 12 0.30 40 1.02 0.36 9.1 0.58 14.7 50 1.27 0.69 17.5 0.38
195
290
EX / 20 8 15 0.38 22 12 0.30 50 1.27 0.49 12.4 0.71 18.0 50 1.27 0.82 20.8 0.54
277
413
EX / 20 10 15 0.38 22 12 0.30 50 1.27 0.53 13.5 0.75 19.1 50 1.27 0.86 21.8 0.59
337
501
EX / 20 12 15 0.38 22 12 0.30 50 1.27 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1 0.66
354
527
EX / 20 16 15 0.38 22 12 0.30 50 1.27 0.62 15.7 0.84 21.3 50 1.27 0.95 24.1 0.72
422
628
EX / 20 20 15 0.38 22 12 0.30 60 1.52 0.75 19.1 0.97 24.6 50 1.27 1.08 27.4 0.93
485
721
EX / 20 24 15 0.38 22 12 0.30 60 1.52 0.77 19.6 1.02 25.9 50 1.27 1.13 28.7 1.02
552
821
EX / 20 36 15 0.38 22 12 0.30 70 1.78 0.94 23.9 1.19 30.2 50 1.27 1.30 33.0 1.34
738
1,099
EX / 20 50 15 0.38 22 12 0.30 70 1.78 1.09 27.7 1.34 34.0 50 1.27 1.45 36.8 1.67
925
1,377
20 AWG TYPE JX MULTIPLE PAIRS OVERALL SHIELDED THERMOCOUPLE EXTENSION CABLE
JX / 20 4 15 0.38 22 12 0.30 40 1.02 0.36 9.1 0.58 14.7 50 1.27 0.69 17.5 0.38
194
288
JX / 20 8 15 0.38 22 12 0.30 50 1.27 0.49 12.4 0.71 18.0 50 1.27 0.82 20.8 0.54
276
411
JX / 20 10 15 0.38 22 12 0.30 50 1.27 0.53 13.5 0.75 19.1 50 1.27 0.86 21.8 0.59
335
498
JX / 20 12 15 0.38 22 12 0.30 50 1.27 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1 0.66
352
524
JX / 20 16 15 0.38 22 12 0.30 50 1.27 0.62 15.7 0.84 21.3 50 1.27 0.95 24.1 0.72
419
624
JX / 20 20 15 0.38 22 12 0.30 60 1.52 0.75 19.1 0.97 24.6 50 1.27 1.08 27.4 0.93
480
715
JX / 20 24 15 0.38 22 12 0.30 60 1.52 0.77 19.6 1.02 25.9 50 1.27 1.13 28.7 1.02
547
814
JX / 20 36 15 0.38 22 12 0.30 70 1.78 0.94 23.9 1.19 30.2 50 1.27 1.30 33.0 1.34
731
1,088
JX / 20 50 15 0.38 22 12 0.30 70 1.78 1.09 27.7 1.34 34.0 50 1.27 1.45 36.8 1.67
914
1,360
20 AWG TYPE KX MULTIPLE PAIRS OVERALL SHIELDED THERMOCOUPLE EXTENSION CABLE
KX / 20 4 15 0.38 22 12 0.30 40 1.02 0.36 9.1 0.58 14.7 50 1.27 0.69 17.5 0.38
195
290
KX / 20 8 15 0.38 22 12 0.30 50 1.27 0.49 12.4 0.71 18.0 50 1.27 0.82 20.8 0.54
277
413
KX / 20 10 15 0.38 22 12 0.30 50 1.27 0.53 13.5 0.75 19.1 50 1.27 0.86 21.8 0.59
337
501
KX / 20 12 15 0.38 22 12 0.30 50 1.27 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1 0.66
354
527
KX / 20 16 15 0.38 22 12 0.30 50 1.27 0.62 15.7 0.84 21.3 50 1.27 0.95 24.1 0.72
422
628
KX / 20 20 15 0.38 22 12 0.30 60 1.52 0.75 19.1 0.97 24.6 50 1.27 1.08 27.4 0.93
485
721
KX / 20 24 15 0.38 22 12 0.30 60 1.52 0.77 19.6 1.02 25.9 50 1.27 1.13 28.7 1.02
552
821
KX / 20 36 15 0.38 22 12 0.30 70 1.78 0.94 23.9 1.19 30.2 50 1.27 1.30 33.0 1.34
738
1,099
KX / 20 50 15 0.38 22 12 0.30 70 1.78 1.09 27.7 1.34 34.0 50 1.27 1.45 36.8 1.67
925
1,377
20 AWG TYPE TX MULTIPLE PAIRS OVERALL SHIELDED THERMOCOUPLE EXTENSION CABLE
TX / 20 4 15 0.38 22 12 0.30 40 1.02 0.36 9.1 0.58 14.7 50 1.27 0.69 17.5 0.38
196
291
TX / 20 8 15 0.38 22 12 0.30 50 1.27 0.49 12.4 0.71 18.0 50 1.27 0.82 20.8 0.54
279
416
TX / 20 10 15 0.38 22 12 0.30 50 1.27 0.53 13.5 0.75 19.1 50 1.27 0.86 21.8 0.59
339
504
TX / 20 12 15 0.38 22 12 0.30 50 1.27 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1 0.66
354
527
TX / 20 16 15 0.38 22 12 0.30 50 1.27 0.62 15.7 0.84 21.3 50 1.27 0.95 24.1 0.72
426
634
TX / 20 20 15 0.38 22 12 0.30 60 1.52 0.75 19.1 0.97 24.6 50 1.27 1.08 27.4 0.93
489
727
TX / 20 24 15 0.38 22 12 0.30 60 1.52 0.77 19.6 1.02 25.9 50 1.27 1.13 28.7 1.02
557
829
TX / 20 36 15 0.38 22 12 0.30 70 1.78 0.94 23.9 1.19 30.2 50 1.27 1.30 33.0 1.34
747
1,111
TX / 20 50 15 0.38 22 12 0.30 70 1.78 1.09 27.7 1.34 34.0 50 1.27 1.45 36.8 1.67
935
1,392

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC ® Section 392.22.

COND.
TYPE
EX

ANSI MC 96.1 CONDUCTOR ALLOY AND COLOR CODE
POSITIVE WIRE
NEGATIVE WIRE
ALLOY
COLOR
ALLOY
COLOR
Chromel
Purple
Constantan
Red

JX

Iron

White

KX

Chromel

TX

Copper

OVERALL
JACKET COLOR
Purple

Constantan

Red

Black

Yellow

Alumel

Red

Yellow

Blue

Constantan

Red

Blue

TEMP. RANGE
0°C To +200°C

LIMITS OF
ERROR
+/- 1.7°C

NOM. LOOP
RESISTANCE PER
100 FT @ 20°C
70.7 Ohms

0°C To +200°C

+/- 2.2°C

35.7 Ohms

0°C To +200°C

+/- 2.2°C

59.0 Ohms

-60°C To +100°C

+/- 1.0°C

29.8 Ohms

Phone: 888-593-3355
www.generalcable.com

SPEC 9075

April, 2011

CCW Armored Thermocouple, Pairs, Individual and Overall Shield
®

UL Type ITC-HL/PLTC, PVC, 105°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	20 AWG solid alloy wire per ANSI MC
96.1
Insulation:
• Flame-retardant Polyvinyl Chloride
(PVC), rated 105°C per UL Standards
13 and 2250
•	ANSI color-coded insulation, with one
conductor in each pair printed alpha
numerically for easy identification
Shielded Pairs:
•	Isolated and individually twisted pairs
with a Flexfoil® aluminum/polyester
tape shield providing 100% coverage
•	Stranded tinned copper drain wire,
two sizes smaller than insulated
conductors
Cable Assembly:
•	Individually shielded pairs and
communication wire are cabled
together with a left-hand lay
•	Communication wire: 22 AWG
solid bare copper, flame-retardant
Polyvinyl Chloride (PVC), rated 105°C,
orange
Overall Shield:
•	Flexfoil® aluminum/polyester tape
shield providing 100% coverage
•	Stranded tinned copper drain wire,
same size as insulated conductors
Inner Jacket:
•	Flame-retardant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250
•	ANSI color-coded inner jacket
•	Low temperature performance meets
ASTM D746 brittleness temperature
at or below -40°C
•	Nylon rip cord to facilitate jacket
removal

Phone: 888-593-3355
www.generalcable.com

CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569
•	CCW armor conductivity meets the
grounding requirements of NEC
Article 250
Overall Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250
•	ANSI color-coded overall jacket
•	Low temperature performance meets
ASTM D746 brittleness temperature
at or below -40°C

Applications:
•	CCW armored Thermocouple
Extension cables with individually
shielded pairs and an overall shield
provide superior protection and
reliability against physical damage for
use in instrumentation and process
control applications requiring ITC-HL
or PLTC wiring methods where
shielding against both external EMI
and EMI between pairs is required
•	For use as Power Limited Tray Cable
on circuits rated 150 V or less and
5 amps or less in Class 2 or Class 3
circuits in accordance with NEC
Article 725
•	For use as Instrumentation Tray Cable
on circuits rated 150 V or less and 5
amps or less in accordance with NEC
Article 727
•	Recognized for use in Class I, II, and
III, Divisions 1 and 2; or Class I, Zones
1 and 2 hazardous locations per NEC
Articles 501, 502, 503, and 505

Applications: (cont’d)
•	Installed indoors or outdoors, in wet
or dry locations, in a raceway, as
aerial cable on a messenger, in cable
trays, or for direct burial
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides superior
mechanical protection and an
impervious barrier to moisture, gas
and liquids
•	CCW armor provides EMI shielding
performance
•	Meets cold impact at -40°C

Specifications:
Design Adherence:
•	UL 13 Power-Limited Circuit Cables
•	UL 2250 Instrumentation Tray Cable
•	UL 1569 Metal Clad Cables
•	UL 1309/CSA C22.2 No. 245 Marine
Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type PLTC, SUN RES, DIR BUR,
-40°C, UL File # E36118
•	UL Type ITC-HL, UL File # E177408
•	UL Listed Marine Shipboard, UL File
# E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9075

April, 2011

CCW Armored Thermocouple, Pairs, Individual and Overall Shield
®

UL Type ITC-HL/PLTC, PVC, 105°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

CROSSCOMMUNICATION WIRE
WIRE
INSULATION
INNER JACKET NOMINAL
NOMINAL
JACKET
NOMINAL
SECTIONAL
APPROXIMATE
TYPE/ NO. THICKNESS SIZE INS. THICKNESS THICKNESS
CORE O.D. ARMOR O.D. THICKNESS OVERALL O.D.
AREA¹
NET WEIGHT
CATALOG
SIZE
OF
mm
mils mm INCHES mm INCHES mm mils mm INCHES mm
SQ. IN. LBS/1000 FT kg/1000 m
NUMBER
(AWG) PAIRS mils mm AWG mils
20 AWG TYPE EX MULTIPLE PAIRS INDIVIDUAL AND OVERALL SHIELDED THERMOCOUPLE EXTENSION CABLE
9075.20041221 EX / 20 4 15 0.38 22 12 0.30 50 1.27 0.40 10.2 0.62 15.7 50 1.27 0.73 18.5
0.42
235
349
9075.20081221 EX / 20 8 15 0.38 22 12 0.30 50 1.27 0.53 13.5 0.75 19.1 50 1.27 0.86 21.8
0.59
313
466
9075.20101221 EX / 20 10 15 0.38 22 12 0.30 50 1.27 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1
0.66
388
577
9075.20121221 EX / 20 12 15 0.38 22 12 0.30 50 1.27 0.62 15.7 0.84 21.3 50 1.27 0.95 24.1
0.72
417
621
9075.20161221 EX / 20 16 15 0.38 22 12 0.30 60 1.52 0.75 19.1 0.97 24.6 50 1.27 1.08 27.4
0.93
494
735
9075.20201221 EX / 20 20 15 0.38 22 12 0.30 60 1.52 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7
1.09
571
850
9075.20241221 EX / 20 24 15 0.38 22 12 0.30 60 1.52 0.90 22.9 1.15 29.2 50 1.27 1.26 32.0
1.26
681
1,014
9075.20361221 EX / 20 36 15 0.38 22 12 0.30 70 1.78 1.09 27.7 1.34 34.0 50 1.27 1.45 36.8
1.67
877
1,305
9075.20501221 EX / 20 50 15 0.38 22 12 0.30 70 1.78 1.22 31.0 1.47 37.3 50 1.27 1.58 40.1
1.99
1,201
1,787
20 AWG TYPE JX MULTIPLE PAIRS INDIVIDUAL AND OVERALL SHIELDED THERMOCOUPLE EXTENSION CABLE
9075.20041222 JX / 20 4 15 0.38 22 12 0.30 50 1.27 0.40 10.2 0.62 15.7 50 1.27 0.73 18.5
0.42
234
348
9075.20081222 JX / 20 8 15 0.38 22 12 0.30 50 1.27 0.53 13.5 0.75 19.1 50 1.27 0.86 21.8
0.59
311
463
9075.20101222 JX / 20 10 15 0.38 22 12 0.30 50 1.27 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1
0.66
386
574
9075.20121222 JX / 20 12 15 0.38 22 12 0.30 50 1.27 0.62 15.7 0.84 21.3 50 1.27 0.95 24.1
0.72
413
615
9075.20161222 JX / 20 16 15 0.38 22 12 0.30 60 1.52 0.75 19.1 0.97 24.6 50 1.27 1.08 27.4
0.93
491
730
9075.20201222 JX / 20 20 15 0.38 22 12 0.30 60 1.52 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7
1.09
567
844
9075.20241222 JX / 20 24 15 0.38 22 12 0.30 60 1.52 0.90 22.9 1.15 29.2 50 1.27 1.26 32.0
1.26
676
1,006
9075.20361222 JX / 20 36 15 0.38 22 12 0.30 70 1.78 1.09 27.7 1.34 34.0 50 1.27 1.45 36.8
1.67
870
1,295
9075.20501222 JX / 20 50 15 0.38 22 12 0.30 70 1.78 1.22 31.0 1.47 37.3 50 1.27 1.58 40.1
1.99
1,190
1,771
20 AWG TYPE KX MULTIPLE PAIRS INDIVIDUAL AND OVERALL SHIELDED THERMOCOUPLE EXTENSION CABLE
9075.20041223 KX / 20 4 15 0.38 22 12 0.30 50 1.27 0.40 10.2 0.62 15.7 50 1.27 0.73 18.5
0.42
235
349
9075.20081223 KX / 20 8 15 0.38 22 12 0.30 50 1.27 0.53 13.5 0.75 19.1 50 1.27 0.86 21.8
0.59
313
466
9075.20101223 KX / 20 10 15 0.38 22 12 0.30 50 1.27 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1
0.66
388
577
9075.20121223 KX / 20 12 15 0.38 22 12 0.30 50 1.27 0.62 15.7 0.84 21.3 50 1.27 0.95 24.1
0.72
417
621
9075.20161223 KX / 20 16 15 0.38 22 12 0.30 60 1.52 0.75 19.1 0.97 24.6 50 1.27 1.08 27.4
0.93
494
735
9075.20201223 KX / 20 20 15 0.38 22 12 0.30 60 1.52 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7
1.09
571
850
9075.20241223 KX / 20 24 15 0.38 22 12 0.30 60 1.52 0.90 22.9 1.15 29.2 50 1.27 1.26 32.0
1.26
681
1,014
9075.20361223 KX / 20 36 15 0.38 22 12 0.30 70 1.78 1.09 27.7 1.34 34.0 50 1.27 1.45 36.8
1.67
877
1,305
9075.20501223 KX / 20 50 15 0.38 22 12 0.30 70 1.78 1.22 31.0 1.47 37.3 50 1.27 1.58 40.1
1.99
1,201
1,787
20 AWG TYPE TX MULTIPLE PAIRS INDIVIDUAL AND OVERALL SHIELDED THERMOCOUPLE EXTENSION CABLE
9075.20041224 TX / 20 4 15 0.38 22 12 0.30 50 1.27 0.40 10.2 0.62 15.7 50 1.27 0.73 18.5
0.42
236
351
9075.20081224 TX / 20 8 15 0.38 22 12 0.30 50 1.27 0.53 13.5 0.75 19.1 50 1.27 0.86 21.8
0.59
315
469
9075.20101224 TX / 20 10 15 0.38 22 12 0.30 50 1.27 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1
0.66
391
581
9075.20121224 TX / 20 12 15 0.38 22 12 0.30 50 1.27 0.62 15.7 0.84 21.3 50 1.27 0.95 24.1
0.72
418
622
9075.20161224 TX / 20 16 15 0.38 22 12 0.30 60 1.52 0.75 19.1 0.97 24.6 50 1.27 1.08 27.4
0.93
497
739
9075.20201224 TX / 20 20 15 0.38 22 12 0.30 60 1.52 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7
1.09
575
856
9075.20241224 TX / 20 24 15 0.38 22 12 0.30 60 1.52 0.90 22.9 1.15 29.2 50 1.27 1.26 32.0
1.26
686
1,022
9075.20361224 TX / 20 36 15 0.38 22 12 0.30 70 1.78 1.09 27.7 1.34 34.0 50 1.27 1.45 36.8
1.67
884
1,316
9075.20501224 TX / 20 50 15 0.38 22 12 0.30 70 1.78 1.22 31.0 1.47 37.3 50 1.27 1.58 40.1
1.99
1,211
1,802
Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC ® Section 392.22.

COND.
TYPE
EX

ANSI MC 96.1 CONDUCTOR ALLOY AND COLOR CODE
POSITIVE WIRE
NEGATIVE WIRE
ALLOY
COLOR
ALLOY
COLOR
Chromel
Purple
Constantan
Red

JX

Iron

White

KX

Chromel

TX

Copper

OVERALL
JACKET COLOR
Purple

Constantan

Red

Black

Yellow

Alumel

Red

Yellow

Blue

Constantan

Red

Blue

TEMP. RANGE
0°C To +200°C

LIMITS OF
ERROR
+/- 1.7°C

NOM. LOOP
RESISTANCE PER
100 FT @ 20°C
70.7 Ohms

0°C To +200°C

+/- 2.2°C

35.7 Ohms

0°C To +200°C

+/- 2.2°C

59.0 Ohms

-60°C To +100°C

+/- 1.0°C

29.8 Ohms

Phone: 888-593-3355
www.generalcable.com

SPEC 9125

April, 2011

CCW Armored Instrumentation, Pairs/Triads, Overall Shield
®

UL Type ITC-HL/PLTC, XLPE, 300 V, 90°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Class B stranding per ASTM B8
Insulation:
•	Cross-linked Polyethylene (XLPE), rated
90°C per UL Standards 13 and 2250
•	Color-coded per ICEA Method 1:
pairs – black and white; triads – black,
white and red. Each conductor in each
pair or triad is printed alphanumerically
for easy identification
Cable Assembly:
•	Individual pairs or triads and
communication wire are cabled
together with a left hand lay
•	Communication wire: 20 AWG solid
bare copper, Cross-linked Polyethylene
(XLPE), rated 90°C, orange
•	Communication wire is not included on
single pair or single triad cables
Overall Shield:
• Flexfoil® aluminum/polyester tape shield
providing 100% coverage
•	Stranded tinned copper drain wire,
same size as insulated conductors
Inner Jacket:
•	Flame-retardant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250,
black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C
•	Nylon rip cord to facilitate jacket
removal

Phone: 888-593-3355
www.generalcable.com

CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569
•	CCW armor conductivity meets the
grounding requirements of NEC
Article 250
Overall Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250,
black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored Instrumentation
cables with an overall shield provide
superior protection and reliability
against physical damage for use in
instrumentation and process control
applications requiring ITC-HL or PLTC
wiring methods where shielding against
external EMI is required
•	For use as Power Limited Tray Cable on
circuits rated 150 V or less and 5 amps
or less in Class 2 or Class 3 circuits in
accordance with NEC Article 725
•	For use as Instrumentation Tray Cable
on circuits rated 150 V or less and
5 amps or less in accordance with NEC
Article 727
•	Recognized for use in Class I, II, and
III, Divisions 1 and 2; or Class I, Zones
1 and 2 hazardous locations per NEC
Articles 501, 502, 503, and 505
•	Installed indoors or outdoors, in wet or
dry locations, in a raceway, as aerial
cable on a messenger, in cable trays, or
for direct burial

Applications: (cont’d)
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides superior
mechanical protection and an
impervious barrier to moisture, gas
and liquids
•	CCW armor provides EMI shielding
performance
•	Meets cold impact at -40°C

Specifications:
Design Adherence:
•	UL 13 Power-Limited Circuit Cables
•	UL 2250 Instrumentation Tray Cable
•	UL 1569 Metal Clad Cables
•	UL 1309 / CSA C22.2 No. 245 Marine
Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type PLTC, SUN RES, DIR BUR,
-40°C, UL File # E36118
•	UL Type ITC-HL, UL File # E177408
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9125

April, 2011

CCW Armored Instrumentation, Pairs/Triads, Overall Shield
®

UL Type ITC-HL/PLTC, XLPE, 300 V, 90°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
CATALOG
NUMBER

CROSSCOMMUNICATION WIRE
INSULATION
INNER JACKET NOMINAL
NOMINAL
JACKET
NOMINAL SECTIONAL
APPROXIMATE
COND. NO. THICKNESS SIZE INS. THICKNESS THICKNESS
CORE O.D. ARMOR O.D. THICKNESS OVERALL O.D.
AREA¹
NET WEIGHT
SIZE
OF
mm
mils mm INCHES mm INCHES mm mils mm INCHES mm
SQ. IN. LBS/1000 FT kg/1000 m
(AWG) PAIRS mils mm AWG mils
16 AWG 7W (1.31 mm²) OVERALL SHIELDED PAIRS

9125.16010001
9125.16021201
9125.16041201
9125.16081201
9125.16121201
9125.16161201
9125.16241201
9125.16361201
9125.16501201

16
16
16
16
16
16
16
16
16

1
2
4
8
12
16
24
36
50

15
15
15
15
15
15
15
15
15

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

—
20
20
20
20
20
20
20
20

9125.16010002
9125.16021202
9125.16041202
9125.16081202
9125.16121202
9125.16161202
9125.16241202
9125.16361202
9125.16501202

16
16
16
16
16
16
16
16
16

1
2
4
8
12
16
24
36
50

15
15
15
15
15
15
15
15
15

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

—
20
20
20
20
20
20
20
20

—
15
15
15
15
15
15
15
15

—
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

35
40
50
60
60
60
70
70
80

0.89
1.02
1.27
1.52
1.52
1.52
1.78
1.78
2.03

0.26
0.37
0.49
0.65
0.76
0.87
1.01
1.24
1.47

6.6
9.4
12.4
16.5
19.3
22.1
25.7
31.5
37.3

0.43
0.58
0.71
0.89
1.02
1.11
1.34
1.56
1.83

10.9
14.7
18.0
22.6
25.9
28.2
34.0
39.6
46.5

50
50
50
50
50
50
50
60
60

1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.52
1.52

0.54
0.69
0.82
1.00
1.13
1.22
1.45
1.69
1.96

13.7
17.5
20.8
25.4
28.7
31.0
36.8
42.9
49.8

0.23
0.38
0.54
0.80
1.02
1.18
1.67
2.27
3.06

135
235
298
412
562
665
934
1,236
1,734

201
350
443
613
836
990
1,390
1,840
2,580

0.60
0.73
0.86
1.04
1.17
1.35
1.53
1.78
2.05

15.2
18.5
21.8
26.4
29.7
34.3
38.9
45.2
52.1

0.29
0.42
0.59
0.86
1.09
1.45
1.86
2.52
3.34

158
265
358
565
793
965
1,446
1,913
2,585

235
394
533
841
1,179
1,436
2,152
2,846
3,846

16 AWG 7W (1.31 mm²) OVERALL SHIELDED TRIADS
—
15
15
15
15
15
15
15
15

—
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

35
40
50
60
60
70
70
80
80

0.89
1.02
1.27
1.52
1.52
1.78
1.78
2.03
2.03

0.27
0.39
0.52
0.69
0.81
0.95
1.14
1.34
1.57

6.9
9.9
13.2
17.5
20.6
24.1
29.0
34.0
39.9

0.49
0.62
0.75
0.93
1.06
1.24
1.42
1.64
1.92

12.4
15.7
19.1
23.6
26.9
31.5
36.1
41.7
48.8

50
50
50
50
50
50
50
60
60

1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.52
1.52

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC ® Section 392.22.

Phone: 888-593-3355
www.generalcable.com

SPEC 9150

April, 2011

CCW Armored Instrumentation, Pairs/Triads, Individual and Overall Shield
®

UL Type ITC-HL/PLTC, XLPE, 300 V, 90°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Class B stranding per ASTM B8
Insulation:
•	Cross-linked Polyethylene (XLPE),
rated 90°C per UL Standards 13 and
2250
•	Color-coded per ICEA Method 1:
pairs – black and white; triads – black,
white and red. Each conductor in each
pair or triad is printed alphanumerically
for easy identification
Shielded Pairs/Triads:
•	Isolated and individually twisted pairs
or triads with a Flexfoil® aluminum/
polyester tape shield providing 100%
coverage
•	Stranded tinned copper drain wire, two
sizes smaller than insulated conductors
Cable Assembly:
•	Individually shielded pairs or triads
and communication wire are cabled
together with a left-hand lay
•	Communication wire: 20 AWG solid
bare copper, Cross-linked Polyethylene
(XLPE), rated 90°C, orange
Overall Shield:
•	Flexfoil® aluminum/polyester tape shield
providing 100% coverage
•	Stranded tinned copper drain wire,
same size as insulated conductors
Inner Jacket:
•	Flame-retardant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250,
black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C
•	Nylon rip cord to facilitate jacket
removal

Phone: 888-593-3355
www.generalcable.com

CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569
•	CCW armor conductivity meets the
grounding requirements of NEC
Article 250
Overall Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250,
black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored Instrumentation cables
with individually shielded pairs or
triads and an overall shield provide
superior protection and reliability
against physical damage for use in
instrumentation and process control
applications requiring ITC-HL or
PLTC wiring methods where shielding
against both external EMI and EMI
between groups is required
•	For use as Power Limited Tray Cable
on circuits rated 150 V or less and
5 amps or less in Class 2 or Class 3
circuits in accordance with NEC Article
725
•	For use as Instrumentation Tray Cable
on circuits rated 150 V or less and
5 amps or less in accordance with
NEC Article 727
•	Recognized for use in Class I, II, and
III, Divisions 1 and 2; or Class I, Zones
1 and 2 hazardous locations per NEC
Articles 501, 502, 503, and 505

Applications: (cont’d)
•	Installed indoors or outdoors, in wet or
dry locations, in a raceway, as aerial
cable on a messenger, in cable trays,
or for direct burial
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides superior
mechanical protection and an
impervious barrier to moisture,
gas and liquids
•	CCW armor provides EMI shielding
performance
•	Meets cold impact at -40°C

Specifications:
Design Adherence:
•	UL 13 Power-Limited Circuit Cables
•	UL 2250 Instrumentation Tray Cable
•	UL 1569 Metal Clad Cables
•	UL 1309/CSA C22.2 No. 245 Marine
Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type PLTC, SUN RES, DIR BUR,
-40°C, UL File # E36118
•	UL Type ITC-HL, UL File # E177408
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9150

April, 2011

CCW Armored Instrumentation, Pairs/Triads, Individual and Overall Shield
®

UL Type ITC-HL/PLTC, XLPE, 300 V, 90°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
CATALOG
NUMBER

CROSSCOMMUNICATION WIRE
INSULATION
INNER JACKET NOMINAL
NOMINAL
JACKET
NOMINAL SECTIONAL
APPROXIMATE
COND. NO. THICKNESS SIZE INS. THICKNESS THICKNESS
CORE O.D. ARMOR O.D. THICKNESS OVERALL O.D.
AREA¹
NET WEIGHT
SIZE
OF
mm
mils mm INCHES mm INCHES mm mils mm INCHES mm
SQ. IN. LBS/1000 FT kg/1000 m
(AWG) PAIRS mils mm AWG mils
16 AWG 7W (1.31 mm²) OVERALL SHIELDED PAIRS

9150.16010001
9150.16021201
9150.16041201
9150.16081201
9150.16121201
9150.16161201
9150.16241201
9150.16361201
9150.16501201

16
16
16
16
16
16
16
16
16

1
2
4
8
12
16
24
36
50

15
15
15
15
15
15
15
15
15

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

—
20
20
20
20
20
20
20
20

9150.16010002
9150.16021202
9150.16041202
9150.16081202
9150.16121202
9150.16161202
9150.16241202
9150.16361202
9150.16501202

16
16
16
16
16
16
16
16
16

1
2
4
8
12
16
24
36
50

15
15
15
15
15
15
15
15
15

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

—
20
20
20
20
20
20
20
20

—
15
15
15
15
15
15
15
15

—
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

35
40
50
60
60
60
70
70
80

0.89
1.02
1.27
1.52
1.52
1.52
1.78
1.78
2.03

0.26
0.37
0.49
0.65
0.76
0.87
1.01
1.24
1.47

6.6
9.4
12.4
16.5
19.3
22.1
25.7
31.5
37.3

0.43
0.58
0.71
0.89
1.02
1.11
1.34
1.56
1.83

10.9
14.7
18.0
22.6
25.9
28.2
34.0
39.6
46.5

50
50
50
50
50
50
50
60
60

1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.52
1.52

0.54
0.69
0.82
1.00
1.13
1.22
1.45
1.69
1.96

13.7
17.5
20.8
25.4
28.7
31.0
36.8
42.9
49.8

0.23
0.38
0.54
0.80
1.02
1.18
1.67
2.27
3.06

135
235
298
412
562
665
934
1,236
1,734

201
350
443
613
836
990
1,390
1,840
2,580

0.60
0.73
0.86
1.04
1.17
1.35
1.53
1.78
2.05

15.2
18.5
21.8
26.4
29.7
34.3
38.9
45.2
52.1

0.29
0.42
0.59
0.86
1.09
1.45
1.86
2.52
3.34

158
265
358
565
793
965
1,446
1,913
2,585

235
394
533
841
1,179
1,436
2,152
2,846
3,846

16 AWG 7W (1.31 mm²) OVERALL SHIELDED TRIADS
—
15
15
15
15
15
15
15
15

—
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

35
40
50
60
60
70
70
80
80

0.89
1.02
1.27
1.52
1.52
1.78
1.78
2.03
2.03

0.27
0.39
0.52
0.69
0.81
0.95
1.14
1.34
1.57

6.9
9.9
13.2
17.5
20.6
24.1
29.0
34.0
39.9

0.49
0.62
0.75
0.93
1.06
1.24
1.42
1.64
1.92

12.4
15.7
19.1
23.6
26.9
31.5
36.1
41.7
48.8

50
50
50
50
50
50
50
60
60

1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.52
1.52

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC ® Section 392.22.

Phone: 888-593-3355
www.generalcable.com

SPEC 9225

April, 2011

CCW Armored Instrumentation, Pairs/Triads, Overall Shield
®

UL Type ITC-HL/PLTC, PVC, 300 V, 105°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Class B stranding per ASTM B8
Insulation:
•	Flame-retardant Polyvinyl Chloride
(PVC), rated 105°C per UL Standards
13 and 2250
•	Color-coded per ICEA Method 1:
pairs – black and white; triads – black,
white and red. Each conductor in each
pair or triad is printed alphanumerically
for easy identification
Cable Assembly:
•	Individual pairs or triads and
communication wire are cabled
together with a left-hand lay
•	Communication wire: 22 AWG solid
bare copper, flame-retardant Polyvinyl
Chloride (PVC), rated 105°C, orange
•	Communication wire is not included on
single pair or single triad cables
Overall Shield:
•	Flexfoil® aluminum/polyester tape
shield providing 100% coverage
•	Stranded tinned copper drain wire,
same size as insulated conductors
Inner Jacket:
•	Flame-retardant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250,
black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C
•	Nylon rip cord to facilitate jacket
removal
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569
•	CCW armor conductivity meets the
grounding requirements of NEC
Article 250

Phone: 888-593-3355
www.generalcable.com

Overall Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250,
black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored Instrumentation
cables with an overall shield provide
superior protection and reliability
against physical damage for use in
instrumentation and process control
applications requiring ITC-HL or
PLTC wiring methods where shielding
against external EMI is required
•	For use as Power Limited Tray Cable
on circuits rated 150 V or less and
5 amps or less in Class 2 or Class 3
circuits in accordance with NEC Article
725
•	For use as Instrumentation Tray Cable
on circuits rated 150 V or less and
5 amps or less in accordance with
NEC Article 727
•	Recognized for use in Class I, II, and
III, Divisions 1 and 2; or Class I, Zones
1 and 2 hazardous locations per NEC
Articles 501, 502, 503, and 505
•	Installed indoors or outdoors, in wet or
dry locations, in a raceway, as aerial
cable on a messenger, in cable trays,
or for direct burial
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides superior
mechanical protection and an
impervious barrier to moisture, gas
and liquids
•	CCW armor provides EMI shielding
performance
•	Meets cold impact at -40°

Specifications:
Design Adherence:
•	UL 13 Power-Limited Circuit Cables
•	UL 2250 Instrumentation Tray Cable
•	UL 1569 Metal Clad Cables
•	UL 1309/CSA C22.2 No. 245 Marine
Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type PLTC, SUN RES, DIR BUR,
-40°C, UL File # E36118
•	UL Type ITC-HL, UL File # E177408
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9225

April, 2011

CCW Armored Instrumentation, Pairs/Triads, Overall Shield
®

UL Type ITC-HL/PLTC, PVC, 300 V, 105°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
CATALOG
NUMBER
9225.20021221
9225.20041221
9225.20061221
9225.20081221
9225.20101221
9225.20121221
9225.20161221
9225.20201221
9225.20241221
9225.20361221
9225.20501221
9225.18021221
9225.18041221
9225.18061221
9225.18081221
9225.18101221
9225.18121221
9225.18161221
9225.18201221
9225.18241221
9225.18361221
9225.18501221
9225.16010001
9225.16021221
9225.16041221
9225.16061221
9225.16081221
9225.16101221
9225.16121221
9225.16161221
9225.16201221
9225.16241221
9225.16361221
9225.16501221

CATALOG
NUMBER
9225.20041222
9225.20081222
9225.20121222
9225.20161222
9225.20241222
9225.20361222
9225.18041222
9225.18081222
9225.18121222
9225.18161222
9225.18241222
9225.18361222
9225.16010002
9225.16041222
9225.16081222
9225.16121222
9225.16161222
9225.16241222
9225.16361222

COMMUNICATION WIRE INNER JACKET NOMINAL
NOMINAL
JACKET
COND. NO. INSULATION
CORE O.D. ARMOR O.D. THICKNESS
SIZE
OF THICKNESS SIZE INS. THICKNESS THICKNESS
(AWG) PAIRS mils mm AWG mils
mm
mils mm INCHES mm INCHES mm mils mm
20 AWG 7W (0.52 mm²) OVERALL SHIELDED PAIRS
20
2 15 0.38 22
12 0.30 40 1.02 0.35 8.9 0.58 14.7 50 1.27
20
4 15 0.38 22
12 0.30 50 1.27 0.41 10.4 0.62 15.7 50 1.27
20
6 15 0.38 22
12 0.30 50 1.27 0.45 11.4 0.67 17.0 50 1.27
20
8 15 0.38 22
12 0.30 50 1.27 0.49 12.4 0.71 18.0 50 1.27
20
10 15 0.38 22
12 0.30 50 1.27 0.53 13.5 0.75 19.1 50 1.27
20
12 15 0.38 22
12 0.30 50 1.27 0.56 14.2 0.80 20.3 50 1.27
20
16 15 0.38 22
12 0.30 60 1.52 0.66 16.8 0.89 22.6 50 1.27
20
20 15 0.38 22
12 0.30 60 1.52 0.73 18.5 0.97 24.6 50 1.27
20
24 15 0.38 22
12 0.30 60 1.52 0.79 20.1 1.06 26.9 50 1.27
20
36 15 0.38 22
12 0.30 70 1.78 0.94 23.9 1.24 31.5 50 1.27
20
50 15 0.38 22
12 0.30 70 1.78 1.06 26.9 1.34 34.0 50 1.27
18 AWG 7W (0.82 mm²) OVERALL SHIELDED PAIRS
18
2 15 0.38 22
12 0.30 40 1.02 0.37 9.4 0.58 14.7 50 1.27
18
4 15 0.38 22
12 0.30 50 1.27 0.44 11.2 0.67 17.0 50 1.27
18
6 15 0.38 22
12 0.30 50 1.27 0.50 12.7 0.71 18.0 50 1.27
18
8 15 0.38 22
12 0.30 50 1.27 0.55 14.0 0.80 20.3 50 1.27
18
10 15 0.38 22
12 0.30 60 1.52 0.65 16.5 0.89 22.6 50 1.27
18
12 15 0.38 22
12 0.30 60 1.52 0.68 17.3 0.93 23.6 50 1.27
18
16 15 0.38 22
12 0.30 60 1.52 0.77 19.6 1.02 25.9 50 1.27
18
20 15 0.38 22
12 0.30 60 1.52 0.83 21.1 1.06 26.9 50 1.27
18
24 15 0.38 22
12 0.30 60 1.52 0.86 21.8 1.11 28.2 50 1.27
18
36 15 0.38 22
12 0.30 70 1.78 0.99 25.1 1.29 32.8 50 1.27
18
50 15 0.38 22
12 0.30 70 1.78 1.15 29.2 1.47 37.3 50 1.27
16 AWG 7W (1.31 mm²) OVERALL SHIELDED PAIRS
16
1 15 0.38 –
–
–
35 0.89 0.26 6.6 0.43 10.9 50 1.27
16
2 15 0.38 22
12 0.30 40 1.02 0.36 9.1 0.58 14.7 50 1.27
16
4 15 0.38 22
12 0.30 50 1.27 0.48 12.2 0.71 18.0 50 1.27
16
6 15 0.38 22
12 0.30 50 1.27 0.57 14.5 0.80 20.3 50 1.27
16
8 15 0.38 22
12 0.30 60 1.52 0.63 16.0 0.84 21.3 50 1.27
16
10 15 0.38 22
12 0.30 60 1.52 0.69 17.5 0.93 23.6 50 1.27
16
12 15 0.38 22
12 0.30 60 1.52 0.74 18.8 0.97 24.6 50 1.27
16
16 15 0.38 22
12 0.30 60 1.52 0.85 21.6 1.11 28.2 50 1.27
16
20 15 0.38 22
12 0.30 70 1.78 0.96 24.4 1.24 31.5 50 1.27
16
24 15 0.38 22
12 0.30 70 1.78 1.04 26.4 1.34 34.0 50 1.27
16
36 15 0.38 22
12 0.30 70 1.78 1.20 30.5 1.51 38.4 60 1.52
16
50 15 0.38 22
12 0.30 80 2.03 1.33 33.8 1.64 41.7 60 1.52
COMMUNICATION WIRE INNER JACKET NOMINAL
NOMINAL
JACKET
COND. NO. INSULATION
CORE O.D. ARMOR O.D. THICKNESS
SIZE
OF THICKNESS SIZE INS. THICKNESS THICKNESS
(AWG) TRIADS mils mm AWG mils
mm
mils mm INCHES mm INCHES mm mils mm
20 AWG 7W (0.52 mm²) OVERALL SHIELDED TRIADS
20
4 15 0.38 22
12 0.30 50 1.27 0.43 10.9 0.67 17.0 50 1.27
20
8 15 0.38 22
12 0.30 50 1.27 0.52 13.2 0.75 19.1 50 1.27
20
12 15 0.38 22
12 0.30 50 1.27 0.60 15.2 0.84 21.3 50 1.27
20
16 15 0.38 22
12 0.30 60 1.52 0.70 17.8 0.93 23.6 50 1.27
20
24 15 0.38 22
12 0.30 60 1.52 0.84 21.3 1.11 28.2 50 1.27
20
36 15 0.38 22
12 0.30 70 1.78 1.00 25.4 1.29 32.8 50 1.27
18 AWG 7W (0.82 mm²) OVERALL SHIELDED TRIADS
18
4 15 0.38 22
12 0.30 50 1.27 0.49 12.4 0.71 18.0 50 1.27
18
8 15 0.38 22
12 0.30 50 1.27 0.59 15.0 0.80 20.3 50 1.27
18
12 15 0.38 22
12 0.30 60 1.52 0.72 18.3 0.97 24.6 50 1.27
18
16 15 0.38 22
12 0.30 60 1.52 0.82 20.8 1.06 26.9 50 1.27
18
24 15 0.38 22
12 0.30 70 1.78 0.97 24.6 1.24 31.5 50 1.27
18
36 15 0.38 22
12 0.30 70 1.78 1.06 26.9 1.34 34.0 50 1.27
16 AWG 7W (1.31 mm²) OVERALL SHIELDED TRIADS
16
1 15 0.38 35 0.89 0.28 7.1 0.43 10.9 50 1.27
16
4 15 0.38 22
12 0.30 50 1.27 0.51 13.0 0.75 19.1 50 1.27
16
8 15 0.38 22
12 0.30 60 1.52 0.67 17.0 0.89 22.6 50 1.27
16
12 15 0.38 22
12 0.30 60 1.52 0.79 20.1 1.06 26.9 50 1.27
16
16 15 0.38 22
12 0.30 70 1.78 0.92 23.4 1.19 30.2 50 1.27
16
24 15 0.38 22
12 0.30 70 1.78 1.11 28.2 1.42 36.1 50 1.27
16
36 15 0.38 22
12 0.30 80 2.03 1.31 33.3 1.60 40.6 60 1.52

CROSSNOMINAL SECTIONAL
APPROXIMATE
OVERALL O.D.
AREA¹
NET WEIGHT
INCHES mm
SQ. IN. LBS/1000 FT kg/1000 m
0.69
0.73
0.78
0.82
0.86
0.91
1.00
1.08
1.17
1.35
1.45

17.5
18.5
19.8
20.8
21.8
23.1
25.4
27.4
29.7
34.3
36.8

0.38
0.42
0.48
0.54
0.59
0.66
0.80
0.93
1.09
1.45
1.67

174
198
250
283
330
353
432
500
556
711
949

260
294
372
420
492
525
644
744
827
1,058
1,412

0.69
0.78
0.82
0.91
1.00
1.04
1.13
1.17
1.22
1.40
1.58

17.5
19.8
20.8
23.1
25.4
26.4
28.7
29.7
31.0
35.6
40.1

0.38
0.48
0.54
0.66
0.80
0.86
1.02
1.09
1.18
1.56
1.99

206
249
294
337
417
449
536
623
698
965
1,280

307
370
437
501
621
668
797
927
1,038
1,436
1,905

0.54
0.69
0.82
0.91
0.95
1.04
1.08
1.22
1.35
1.45
1.65
1.78

13.7
17.5
20.8
23.1
24.1
26.4
27.4
31.0
34.3
36.8
41.9
45.2

0.23
0.38
0.54
0.66
0.72
0.86
0.93
1.18
1.45
1.67
2.17
2.52

135
239
296
366
424
522
570
687
849
956
1,283
1,786

201
355
440
545
631
777
849
1,023
1,263
1,422
1,910
2,658

CROSSNOMINAL SECTIONAL
APPROXIMATE
OVERALL O.D.
AREA¹
NET WEIGHT
INCHES mm
SQ. IN. LBS/1000 FT kg/1000 m
0.78
0.86
0.95
1.04
1.22
1.40

19.8
21.8
24.1
26.4
31.0
35.6

0.48
0.59
0.72
0.86
1.18
1.56

247
336
427
528
694
955

367
499
636
786
1,032
1,421

0.82
0.91
1.08
1.17
1.35
1.45

20.8
23.1
27.4
29.7
34.3
36.8

0.54
0.66
0.93
1.09
1.45
1.67

291
409
554
671
936
1,256

433
609
824
999
1,393
1,869

0.54
0.86
1.00
1.17
1.30
1.53
1.73

13.7
21.8
25.4
29.7
33.0
38.9
43.9

0.23
0.58
0.80
1.09
1.34
1.86
2.38

160
353
540
727
922
1,254
1,792

238
525
803
1,082
1,372
1,866
2,667

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC ® Section 392.22.

Phone: 888-593-3355
www.generalcable.com

SPEC 9250

April, 2011

CCW Armored Instrumentation, Pairs/Triads, Individual and Overall Shield
®

UL Type ITC-HL/PLTC, PVC, 300 V, 105°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Class B stranding per ASTM B8
Insulation:
•	Flame-retardant Polyvinyl Chloride
(PVC), rated 105°C per UL Standards
13 and 2250
•	Color-coded per ICEA Method 1:
pairs – black and white; triads – black,
white and red. Each conductor in each
pair or triad is printed alphanumerically
for easy identification
Shielded Pairs/Triads:
•	Isolated and individually twisted pairs
or triads with a Flexfoil® aluminum/
polyester tape shield providing 100%
coverage
•	Stranded tinned copper drain wire,
two sizes smaller than insulated
conductors
Cable Assembly:
•	Individually shielded pairs or triads
and communication wire are cabled
together with a left hand lay
•	Communication wire: 22 AWG solid
bare copper, flame-retardant Polyvinyl
Chloride (PVC), rated 105°C, orange
Overall Shield:
•	Flexfoil® aluminum/polyester tape
shield providing 100% coverage
•	Stranded tinned copper drain wire,
same size as insulated conductors
Inner Jacket:
•	Flame-retardant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250,
black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C
•	Nylon rip cord to facilitate jacket
removal

Phone: 888-593-3355
www.generalcable.com

CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569
•	CCW armor conductivity meets the
grounding requirements of NEC
Article 250
Overall Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC) per UL Standards 13 and 2250,
black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored Instrumentation cables
with individually shielded pairs or
triads and an overall shield provide
superior protection and reliability
against physical damage for use in
instrumentation and process control
applications requiring ITC-HL or
PLTC wiring methods where shielding
against both external EMI and EMI
between groups is required
•	For use as Power Limited Tray Cable
on circuits rated 150 V or less and
5 amps or less in Class 2 or Class 3
circuits in accordance with NEC Article
725
•	For use as Instrumentation Tray Cable
on circuits rated 150 V or less and
5 amps or less in accordance with
NEC Article 727
•	Recognized for use in Class I, II, and
III, Divisions 1 and 2; or Class I, Zones
1 and 2 hazardous locations per NEC
Articles 501, 502, 503, and 505

Applications: (cont’d)
•	Installed indoors or outdoors, in wet or
dry locations, in a raceway, as aerial
cable on a messenger, in cable trays,
or for direct burial
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides superior
mechanical protection and an
impervious barrier to moisture, gas
and liquids
•	CCW armor provides EMI shielding
performance
•	Meets cold impact at -40°C

Specifications:
Design Adherence:
•	UL 13 Power-Limited Circuit Cables
•	UL 2250 Instrumentation Tray Cable
•	UL 1569 Metal Clad Cables
•	UL 1309/CSA C22.2 No. 245 Marine
Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type PLTC, SUN RES, DIR BUR,
-40°C, UL File # E36118
•	UL Type ITC-HL, UL File # E177408
•	UL Listed Marine Shipboard, UL File
# E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9250

April, 2011

CCW Armored Instrumentation, Pairs/Triads, Individual and Overall Shield
®

UL Type ITC-HL/PLTC, PVC, 300 V, 105°C, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
CATALOG
NUMBER
9250.20021221
9250.20041221
9250.20061221
9250.20081221
9250.20101221
9250.20121221
9250.20161221
9250.20201221
9250.20241221
9250.20361221
9250.20501221
9250.18021221
9250.18041221
9250.18061221
9250.18081221
9250.18101221
9250.18121221
9250.18161221
9250.18201221
9250.18241221
9250.18361221
9250.18501221
9250.16021221
9250.16041221
9250.16061221
9250.16081221
9250.16101221
9250.16121221
9250.16161221
9250.16201221
9250.16241221
9250.16361221
9250.16501221

CATALOG
NUMBER
9250.20041222
9250.20081222
9250.20121222
9250.20161222
9250.20241222
9250.20361222
9250.18041222
9250.18081222
9250.18121222
9250.18161222
9250.18241222
9250.18361222
9250.16041222
9250.16081222
9250.16121222
9250.16161222
9250.16241222
9250.16361222

CROSSCOMMUNICATION WIRE INNER JACKET NOMINAL
NOMINAL
JACKET
NOMINAL SECTIONAL
APPROXIMATE
COND. NO. INSULATION
CORE O.D. ARMOR O.D. THICKNESS OVERALL O.D.
AREA¹
NET WEIGHT
SIZE
OF THICKNESS SIZE INS. THICKNESS THICKNESS
(AWG) PAIRS mils mm AWG mils
mm
mils mm INCHES mm INCHES mm mils mm INCHES mm
SQ. IN. LBS/1000 FT kg/1000 m
20 AWG 7W (0.52 mm²) INDIVIDUAL AND OVERALL SHIELDED PAIRS
20
2 15 0.38 22
12 0.30 40 1.02 0.36 9.1 0.58 14.7 50 1.27 0.69 17.5 0.38
202
301
20
4 15 0.38 22
12 0.30 50 1.27 0.43 10.9 0.62 15.7 50 1.27 0.73 18.5 0.42
239
355
20
6 15 0.38 22
12 0.30 50 1.27 0.48 12.2 0.71 18.0 50 1.27 0.82 20.8 0.54
292
434
20
8 15 0.38 22
12 0.30 50 1.27 0.53 13.5 0.75 19.1 50 1.27 0.86 21.8 0.59
323
481
20
10 15 0.38 22
12 0.30 50 1.27 0.57 14.5 0.80 20.3 50 1.27 0.91 23.1 0.66
401
597
20
12 15 0.38 22
12 0.30 60 1.52 0.63 16.0 0.84 21.3 50 1.27 0.95 24.1 0.72
439
653
20
16 15 0.38 22
12 0.30 60 1.52 0.72 18.3 0.97 24.6 50 1.27 1.08 27.4 0.93
511
760
20
20 15 0.38 22
12 0.30 60 1.52 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7 1.09
593
882
20
24 15 0.38 22
12 0.30 70 1.78 0.90 22.9 1.15 29.2 50 1.27 1.26 32.0 1.26
718
1,069
20
36 15 0.38 22
12 0.30 70 1.78 1.04 26.4 1.34 34.0 50 1.27 1.45 36.8 1.67
925
1,377
1,255
1,867
20
50 15 0.38 22
12 0.30 70 1.78 1.19 30.2 1.51 38.4 60 1.52 1.65 41.9 2.17
18 AWG 7W (0.82 mm²) INDIVIDUAL AND OVERALL SHIELDED PAIRS
18
2 15 0.38 22
12 0.30 40 1.02 0.38 9.7 0.58 14.7 50 1.27 0.69 17.5 0.38
216
322
18
4 15 0.38 22
12 0.30 50 1.27 0.49 12.4 0.71 18.0 50 1.27 0.82 20.8 0.54
278
414
18
6 15 0.38 22
12 0.30 50 1.27 0.55 14.0 0.75 19.1 50 1.27 0.86 21.8 0.59
345
513
18
8 15 0.38 22
12 0.30 50 1.27 0.60 15.2 0.80 20.3 50 1.27 0.92 23.4 0.67
397
590
18
10 15 0.38 22
12 0.30 60 1.52 0.67 17.0 0.89 22.6 50 1.27 1.00 25.4 0.80
489
727
18
12 15 0.38 22
12 0.30 60 1.52 0.71 18.0 0.93 23.6 50 1.27 1.04 26.4 0.86
540
803
18
16 15 0.38 22
12 0.30 60 1.52 0.79 20.1 1.06 26.9 50 1.27 1.17 29.7 1.09
645
959
18
20 15 0.38 22
12 0.30 60 1.52 0.88 22.4 1.15 29.2 50 1.27 1.26 32.0 1.26
794
1,181
18
24 15 0.38 22
12 0.30 70 1.78 0.98 24.9 1.24 31.5 50 1.27 1.35 34.3 1.45
907
1,349
18
36 15 0.38 22
12 0.30 70 1.78 1.15 29.2 1.47 37.3 50 1.27 1.58 40.1 1.99
1,227
1,826
18
50 15 0.38 22
12 0.30 80 2.03 1.36 34.5 1.69 42.9 60 1.52 1.82 46.2 2.64
1,662
2,473
16 AWG 7W (1.31 mm²) INDIVIDUAL AND OVERALL SHIELDED PAIRS
16
2 15 0.38 22
12 0.30 50 1.27 0.44 11.2 0.67 17.0 50 1.27 0.78 19.8 0.48
260
387
16
4 15 0.38 22
12 0.30 50 1.27 0.52 13.2 0.71 18.0 50 1.27 0.82 20.8 0.54
334
496
16
6 15 0.38 22
12 0.30 50 1.27 0.59 15.0 0.84 21.3 50 1.27 0.95 24.1 0.72
443
659
16
8 15 0.38 22
12 0.30 60 1.52 0.69 17.5 0.93 23.6 50 1.27 1.04 26.4 0.86
515
767
16
10 15 0.38 22
12 0.30 60 1.52 0.75 19.1 1.02 25.9 50 1.27 1.13 28.7 1.02
616
917
16
12 15 0.38 22
12 0.30 60 1.52 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7 1.09
684
1,019
16
16 15 0.38 22
12 0.30 70 1.78 0.95 24.1 1.24 31.5 50 1.27 1.35 34.3 1.45
872
1,298
12 0.30 70 1.78 1.03 26.2 1.34 34.0 50 1.27 1.45 36.8 1.67
1,024
1,524
16
20 15 0.38 22
16
24 15 0.38 22
12 0.30 70 1.78 1.10 27.9 1.37 34.8 50 1.27 1.48 37.6 1.74
1,270
1,890
16
36 15 0.38 22
12 0.30 80 2.03 1.29 32.8 1.60 40.6 60 1.52 1.73 43.9 2.38
1,712
2,547
16
50 15 0.38 22
12 0.30 80 2.03 1.53 38.9 1.87 47.5 60 1.52 2.00 50.8 3.18
2,215
3,297
CROSSCOMMUNICATION WIRE INNER JACKET NOMINAL
NOMINAL
JACKET
NOMINAL SECTIONAL
APPROXIMATE
COND. NO. INSULATION
CORE O.D. ARMOR O.D. THICKNESS OVERALL O.D.
AREA¹
NET WEIGHT
SIZE
OF THICKNESS SIZE INS. THICKNESS THICKNESS
(AWG) TRIADS mils mm AWG mils
mm
mils mm INCHES mm INCHES mm mils mm INCHES mm
SQ. IN. LBS/1000 FT kg/1000 m
20 AWG 7W (0.52 mm²) INDIVIDUAL AND OVERALL SHIELDED TRIADS
20
4 15 0.38 22
12 0.30 50 1.27 0.45 11.4 0.67 17.0 50 1.27 0.78 19.8 0.48
263
392
20
8 15 0.38 22
12 0.30 50 1.27 0.56 14.2 0.80 20.3 50 1.27 0.91 23.1 0.66
376
560
20
12 15 0.38 22
12 0.30 60 1.52 0.67 17.0 0.89 22.6 50 1.27 1.00 25.4 0.80
514
765
20
16 15 0.38 22
12 0.30 60 1.52 0.77 19.6 1.02 25.9 50 1.27 1.13 28.7 1.02
616
917
20
24 15 0.38 22
12 0.30 70 1.78 0.96 24.4 1.24 31.5 50 1.27 1.35 34.3 1.45
869
1,293
20
36 15 0.38 22
12 0.30 70 1.78 1.11 28.2 1.42 36.1 50 1.27 1.53 38.9 1.86
1,139
1,696
18 AWG 7W (0.82 mm²) INDIVIDUAL AND OVERALL SHIELDED TRIADS
18
4 15 0.38 22
12 0.30 50 1.27 0.54 13.7 0.75 19.1 50 1.27 0.86 21.8 0.59
320
477
18
8 15 0.38 22
12 0.30 60 1.52 0.69 17.5 0.93 23.6 50 1.27 1.04 26.4 0.86
485
721
18
12 15 0.38 22
12 0.30 60 1.52 0.79 20.1 1.06 26.9 50 1.27 1.17 29.7 1.09
645
959
18
16 15 0.38 22
12 0.30 70 1.78 0.90 22.9 1.15 29.2 50 1.27 1.26 32.0 1.26
797
1,185
18
24 15 0.38 22
12 0.30 70 1.78 1.06 26.9 1.34 34.0 50 1.27 1.45 36.8 1.67
1,119
1,665
18
36 15 0.38 22
12 0.30 80 2.03 1.29 32.8 1.60 40.6 60 1.52 1.73 43.9 2.38
1,570
2,336
16 AWG 7W (1.31 mm²) INDIVIDUAL AND OVERALL SHIELDED TRIADS
16
4 15 0.38 22
12 0.30 50 1.27 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1 0.58
392
583
16
8 15 0.38 22
12 0.30 60 1.52 0.79 20.1 1.02 25.9 50 1.27 1.13 28.7 1.02
621
924
16
12 15 0.38 22
12 0.30 70 1.78 0.95 24.1 1.19 30.2 50 1.27 1.30 33.0 1.34
879
1,308
16
16 15 0.38 22
12 0.30 70 1.78 1.04 26.4 1.34 34.0 50 1.27 1.45 36.8 1.67
1,074
1,598
16
24 15 0.38 22
12 0.30 80 2.03 1.27 32.3 1.60 40.6 60 1.52 1.73 43.9 2.38
1,605
2,389
16
36 15 0.38 22
12 0.30 80 2.03 1.49 37.8 1.83 46.5 60 1.52 1.96 49.8 3.06
2,161
3,216

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC ® Section 392.22.

Phone: 888-593-3355
www.generalcable.com

SPEC 9325

February, 2011

CCW Armored Instrumentation, Pairs/Triads, Overall Shield
®

UL Type MC-HL, PVC/Nylon, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Class B stranding per ASTM B8
Insulation:
•	Flame-retardant Polyvinyl Chloride
(PVC) insulation and nylon covering,
rated 90°C per UL Standard 83
•	Color-coded per ICEA Method 1:
pairs – black and white; triads – black,
white and red. Each conductor in each
pair or triad is printed alphanumerically
for easy identification
Cable Assembly:
•	Individual pairs or triads are cabled
together with a left-hand lay
Overall Shield:
•	Flexfoil® aluminum/polyester tape shield
providing 100% coverage
•	Stranded tinned copper drain wire,
same size as insulated conductors
Inner Jacket:
•	Flame-retardant Polyvinyl Chloride
(PVC) per UL Standard 1569, black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C
•	Nylon rip cord to facilitate jacket
removal
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL Standards 1569 and 2225
•	CCW armor conductivity meets the
grounding requirements of NEC Article
250

Phone: 888-593-3355
www.generalcable.com

Overall Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC) per UL Standard 1569, black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored 600 volt Instrumentation
cables with an overall shield provide
superior protection and reliability
against physical damage for use in
instrumentation and process control
applications where shielding against
external EMI is required
•	For use in Class 1 remote-control and
signal circuits in accordance with NEC
Article 725
•	Recognized for use in Class I, II and
III, Divisions 1 and 2; or Class I, Zones
1 and 2 hazardous locations per NEC
Articles 501, 502, 503 and 505
•	Installed indoors or outdoors, in wet or
dry locations, in a raceway, as aerial
cable on a messenger, in cable trays,
or for direct burial
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides superior
mechanical protection and an
impervious barrier to moisture, gas
and liquids
•	CCW armor provides EMI shielding
performance
•	Meets cold impact at -40°C

Specifications:
Design Adherence:
•	UL 83 Thermoplastic Insulated Wire
and Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309/CSA C22.2 No. 245 Marine
Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type MC-HL, CT USE, SUN RES,
DIR BUR, -40°C, UL File # E69797
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9325

February, 2011

CCW Armored Instrumentation, Pairs/Triads, Overall Shield
®

UL Type MC-HL, PVC/Nylon, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
CATALOG
NUMBER

COND.
SIZE
(AWG)

NO. OF
PAIRS

INSULATION
THICKNESS
mils
mm

INNER JACKET
NOMINAL
THICKNESS
CORE O.D.
mils
mm INCHES mm

NOMINAL
ARMOR O.D.
INCHES mm

JACKET
THICKNESS
mils
mm

CROSSNOMINAL
SECTIONAL APPROXIMATE NET
OVERALL O.D.
AREA¹
WEIGHT
INCHES mm
SQ. IN. LBS/1000 FT kg/1000 m

18 AWG 7W (0.82 mm²) OVERALL SHIELDED PAIRS
9325.18020001

18

2

19

0.48

40

1.02

0.41 10.4

0.59

15.0

50

1.27

0.70

17.8

0.39

222

9325.18040001

18

4

19

0.48

40

1.02

0.48 12.2

0.65

16.5

50

1.27

0.75

19.1

0.45

268

399

9325.18080001

18

8

19

0.48

50

1.27

0.60 15.2

0.82

20.8

50

1.27

0.92

23.4

0.67

420

625

330

9325.18120001

18

12

19

0.48

50

1.27

0.78 19.8

1.00

25.4

50

1.27

1.10

27.9

0.96

560

833

9325.18160001

18

16

19

0.48

50

1.27

0.81 20.6

1.12

28.4

50

1.27

1.23

31.2

1.20

706

1,051

9325.18240001

18

24

19

0.48

50

1.27

1.08 27.4

1.39

35.3

50

1.27

1.49

37.8

1.77

969

1,442

16 AWG 7W (1.31 mm²) OVERALL SHIELDED PAIRS
9325.16010001

16

1

19

0.48

60

1.52

0.35

8.9

0.53

13.5

50

1.27

0.64

16.3

0.33

185

275

9325.16020001

16

2

19

0.48

40

1.02

0.38

9.7

0.58

14.7

50

1.27

0.69

17.5

0.38

246

366

9325.16040001

16

4

19

0.48

40

1.02

0.47

11.9

0.71

18.0

50

1.27

0.82

20.8

0.54

333

495

9325.16060001

16

6

19

0.48

50

1.27

0.58

14.7

0.80

20.3

50

1.27

0.91

23.1

0.66

405

603

9325.16080001

16

8

19

0.48

50

1.27

0.66

16.8

0.89

22.6

50

1.27

1.00

25.4

0.80

466

694

9325.16100001

16

10

19

0.48

50

1.27

0.76

19.3

1.02

25.9

50

1.27

1.13

28.7

1.02

556

827

9325.16120001

16

12

19

0.48

50

1.27

0.80

20.3

1.06

26.9

50

1.27

1.17

29.7

1.09

604

899

9325.16160001

16

16

19

0.48

50

1.27

0.87

22.1

1.15

29.2

50

1.27

1.26

32.0

1.26

799

1,189

9325.16200001

16

20

19

0.48

50

1.27

0.98

24.9

1.29

32.8

50

1.27

1.40

35.6

1.56

929

1,383

9325.16240001

16

24

19

0.48

50

1.27

1.08

27.4

1.37

34.8

50

1.27

1.48

37.6

1.74

1,040

1,548

9325.16360001

16

36

19

0.48

50

1.27

1.32

33.5

1.64

41.7

60

1.52

1.78

45.2

2.52

1,445

2,151

9325.16500001

16

50

19

0.48

50

1.27

1.48

37.6

1.83

46.5

60

1.52

1.96

49.8

3.06

1,897

2,823

CATALOG
NUMBER

COND.
SIZE
(AWG)

NO. OF
TRIADS

INSULATION
THICKNESS

INNER JACKET
THICKNESS

mils

mils

mm

mm

NOMINAL
CORE O.D.
INCHES

mm

NOMINAL
ARMOR O.D.
INCHES

mm

OVERALL
JACKET
THICKNESS
mils

mm

CROSSNOMINAL
SECTIONAL
OVERALL O.D.
AREA¹
INCHES

mm

SQ. IN.

APPROXIMATE NET
WEIGHT
LBS/1000 FT kg/1000 m

16 AWG 7W (1.31 mm²) OVERALL SHIELDED TRIADS
9325.16010002

16

1

19

0.48

50

1.27

0.35

8.9

0.53

13.5

50

1.27

0.64

16.3

0.33

195

290

9325.16040002

16

4

19

0.48

40

1.02

0.51 13.0

0.71

18.0

50

1.27

0.82

20.8

0.54

407

606

9325.16080002

16

8

19

0.48

50

1.27

0.71 18.0

0.93

23.6

50

1.27

1.04

26.4

0.86

617

918

9325.16120002

16

12

19

0.48

50

1.27

0.85 21.6

1.11

28.2

50

1.27

1.22

31.0

1.18

897

1,334

9325.16160002

16

16

19

0.48

50

1.27

0.93 23.6

1.19

30.2

50

1.27

1.30

33.0

1.34

1,161

1,727

9325.16240002

16

24

19

0.48

50

1.27

1.16 29.5

1.47

37.3

50

1.27

1.58

40.1

1.99

1,581

2,353

9325.16360002

16

36

19

0.48

50

1.27

1.42 36.1

1.74

44.2

60

1.52

1.87

47.5

2.78

2,142

3,188

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC® Section 392.22.

Phone: 888-593-3355
www.generalcable.com

SPEC 9350

February, 2011

CCW Armored Instrumentation, Pairs/Triads, Individual and Overall Shield
®

UL Type MC-HL, PVC/Nylon, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Class B stranding per ASTM B8
Insulation:
•	Flame-retardant Polyvinyl Chloride
(PVC) insulation and nylon covering,
rated 90°C per UL Standard 83
•	Color-coded per ICEA Method 1:
pairs – black and white; triads – black,
white and red. Each conductor in each
pair or triad is printed alphanumerically
for easy identification
Shielded Pairs/Triads:
•	Isolated and individually twisted pairs
or triads with a Flexfoil® aluminum/
polyester tape shield providing 100%
coverage
•	Stranded tinned copper drain wire, two
sizes smaller than insulated conductors
Cable Assembly:
•	Individually shielded pairs or triads are
cabled together with a left-hand lay
Overall Shield:
•	Flexfoil® aluminum/polyester tape shield
providing 100% coverage
•	Stranded tinned copper drain wire,
same size as insulated conductors
Inner Jacket:
•	Flame-retardant Polyvinyl Chloride
(PVC) per UL Standard 1569, black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C
•	Nylon rip cord to facilitate jacket
removal

Phone: 888-593-3355
www.generalcable.com

CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL Standards 1569 and 2225
•	CCW armor conductivity meets the
grounding requirements of NEC Article
250
Overall Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC) per UL Standard 1569, black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored 600 volt Instrumentation
cables with individually shielded pairs
or triads and an overall shield provide
superior protection and reliability
against physical damage for use in
instrumentation and process control
applications where shielding against
both external EMI and EMI between
groups is required
•	For use in Class 1 remote-control and
signal circuits in accordance with NEC
Article 725
•	Recognized for use in Class I, II and
III, Divisions 1 and 2; or Class I, Zones
1 and 2 hazardous locations per NEC
Articles 501, 502, 503 and 505
•	Installed indoors or outdoors, in wet or
dry locations, in a raceway, as aerial
cable on a messenger, in cable trays,
or for direct burial
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides superior
mechanical protection and an
impervious barrier to moisture, gas
and liquids
•	CCW armor provides EMI shielding
performance
•	Meets cold impact at -40°C

Specifications:
Design Adherence:
•	UL 83 Thermoplastic Insulated Wire
and Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309/CSA C22.2 No. 245 Marine
Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type MC-HL, CT USE, SUN RES,
DIR BUR, -40°C, UL File # E69797
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9350

February, 2011

CCW Armored Instrumentation, Pairs/Triads, Individual and Overall Shield
®

UL Type MC-HL, PVC/Nylon, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
CATALOG
NUMBER

COND.
SIZE NO. OF
(AWG) PAIRS

INSULATION
THICKNESS
mils
mm

INNER JACKET
NOMINAL
THICKNESS
CORE O.D.
mils
mm INCHES mm

NOMINAL
ARMOR O.D.
INCHES mm

OVERALL
JACKET
THICKNESS
mils
mm

NOMINAL
OVERALL O.D.
INCHES mm

CROSSSECTIONAL
APPROXIMATE
AREA¹
NET WEIGHT
SQ. IN. LBS/1000 FT kg/1000 m

18 AWG 7W (0.82 mm²) INDIVIDUAL AND OVERALL SHIELDED PAIRS
9350.18020001

18

2

19

0.48

40

1.02

0.41

10.4

0.59

15.0

50

1.27

0.70

17.8

0.39

225

335

9350.18040001

18

4

19

0.48

40

1.02

0.48

12.2

0.65

16.5

50

1.27

0.75

19.1

0.45

300

446

9350.18080001

18

8

19

0.48

50

1.27

0.60

15.2

0.82

20.8

50

1.27

0.92

23.4

0.67

450

670

9350.18120001

18

12

19

0.48

50

1.27

0.78

19.8

1.00

25.4

50

1.27

1.10

27.9

0.96

580

863

9350.18160001

18

16

19

0.48

50

1.27

0.81

20.6

1.12

28.4

50

1.27

1.23

31.2

1.20

760

1,131

9350.18240001

18

24

19

0.48

50

1.27

1.08

27.4

1.39

35.3

50

1.27

1.49

37.8

1.77

1,050

1,563

9350.16020001

16

2

19

0.48

40

1.02

0.45

11.4

0.67

17.0

50

1.27

0.78

19.8

0.48

239

355

9350.16040001

16

4

19

0.48

50

1.27

0.56

14.2

0.80

20.3

50

1.27

0.91

23.1

0.66

342

509

9350.16060001

16

6

19

0.48

50

1.27

0.66

16.8

0.89

22.6

50

1.27

1.00

25.4

0.80

429

639

9350.16080001

16

8

19

0.48

50

1.27

0.70

17.8

0.93

23.6

50

1.27

1.04

26.4

0.86

502

747

9350.16100001

16

10

19

0.48

50

1.27

0.79

20.1

1.06

26.9

50

1.27

1.17

29.7

1.09

613

912

9350.16120001

16

12

19

0.48

50

1.27

0.85

21.6

1.11

28.2

50

1.27

1.22

31.0

1.18

687

1,023

9350.16160001

16

16

19

0.48

50

1.27

0.98

24.9

1.29

32.8

50

1.27

1.40

35.6

1.56

859

1,278

9350.16200001

16

20

19

0.48

50

1.27

1.06

26.9

1.34

34.0

50

1.27

1.45

36.8

1.67

997

1,483

9350.16240001

16

24

19

0.48

50

1.27

1.12

28.4

1.42

36.1

50

1.27

1.53

38.9

1.86

1,140

1,697

9350.16360001

16

36

19

0.48

50

1.27

1.37

34.8

1.69

42.9

60

1.52

1.82

46.2

2.64

1,618

2,407

9350.16500001

16

50

19

0.48

50

1.27

1.57

39.9

1.92

48.8

60

1.52

2.05

52.1

3.34

2,166

3,224

16 AWG 7W (1.31 mm²) INDIVIDUAL AND OVERALL SHIELDED PAIRS

CATALOG
NUMBER

COND.
SIZE NO. OF
(AWG) TRIADS

INSULATION
THICKNESS

INNER JACKET
THICKNESS

mils

mils

mm

mm

NOMINAL
CORE O.D.
INCHES

mm

NOMINAL
ARMOR O.D.
INCHES

mm

OVERALL
JACKET
THICKNESS
mils

mm

NOMINAL
OVERALL O.D.
INCHES

mm

CROSSSECTIONAL
AREA¹

APPROXIMATE
NET WEIGHT

SQ. IN.

LBS/1000 FT kg/1000 m

16 AWG 7W (1.31 mm²) INDIVIDUAL AND OVERALL SHIELDED TRIADS
9350.16040002

16

4

19

0.48

50

1.27

0.61

15.5

0.84

21.3

50

1.27

0.95

24.1

0.72

403

9350.16080002

16

8

19

0.48

50

1.27

0.82

20.8

1.06

26.9

50

1.27

1.17

29.7

1.09

650

967

9350.16120002

16

12

19

0.48

50

1.27

0.98

24.9

1.24

31.5

50

1.27

1.35

34.3

1.45

853

1,269

9350.16160002

16

16

19

0.48

50

1.27

1.10

27.9

1.37

34.8

50

1.27

1.48

37.6

1.74

1,079

1,606

9350.16240002

16

24

19

0.48

50

1.27

1.33

33.8

1.64

41.7

60

1.52

1.78

45.2

2.52

1,515

2,254

9350.16360002

16

36

19

0.48

50

1.27

1.58

40.1

1.96

49.8

60

1.52

2.09

53.1

3.48

2,184

3,250

600

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC ® Section 392.22.

Phone: 888-593-3355
www.generalcable.com

SPEC 9500

February, 2011

CCW Armored Control With Grounding Conductor
®

UL Type MC-HL, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Compressed Class B stranding per
ASTM B8
Insulation:
•	Cross-linked Polyethylene (XLPE)
insulation per ICEA S-73-532 and UL
44, Listed XHHW-2
•	Color-coded per ICEA Method 1, Table
E2, full-colored insulation with stripes
•	Color-coded per CSA C22.2 No. 123
where applicable
Grounding Conductor:
•	Class B stranded bare annealed
copper per ASTM B3 and B8
•	Cross-linked Polyethylene (XLPE)
insulation, green
•	Sized in accordance with NEC Table
250.122
Cable Assembly:
•	Insulated conductors and grounding
wire are cabled together with nonhygroscopic fillers when required
•	A binder tape, when required, is
applied over the cabled core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569 and UL 2225
•	CCW armor conductivity meets the
grounding requirements of NEC
Article 250
Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC), black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C
•	Meets CSA Low Acid Gas
requirements

Phone: 888-593-3355
www.generalcable.com

Applications:

Specifications:

•	CCW armored Control cables offer
an economical, rugged and reliable
alternative to labor-intensive cable in
conduit wiring methods
•	For use in Class I, II and III, Divisions
1 and 2; and Class I, Zones 1 and 2
hazardous locations per NEC Articles
501, 502, 503 and 505
•	For use as services, feeders and
branch circuits for power, lighting,
control, and signal circuits in
accordance with NEC Articles 330
and 725
•	Installed indoors or outdoors, wet
or dry locations, directly buried,
embedded in concrete, in a raceway,
as aerial cable on a messenger,
in cable trays, or as exposed runs
secured to supports in accordance
with NEC Article 330
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Design Adherence:
•	ICEA S-73-532/WC57 Standard for
Control, Thermocouple Extension and
Instrumentation Cables
•	UL 44 Rubber Insulated Wires and
Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309 Marine Shipboard Cable
•	CSA C22.2 No. 123 Metal Sheathed
Cables
•	CSA C22.2 No. 174 Cables and Cable
Glands for Use in Hazardous Locations
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type MC-HL, XHHW-2, SUN RES,
CT USE, DIR BUR, -40°C, UL File
# E69797
•	UL Listed Marine Shipboard, UL File
# E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC
•	CSA Certified Type RA90, XLPE,
HL, SR, FT4, and -40°C, CSA File
# 7319

Features:
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
•	CCW armor provides EMI shielding
performance
•	Factory assembled and tested cable
for use as an alternative to cable in
conduit wiring systems
•	Meets cold impact at -40°C
•	90˚C continuous operating
temperature, wet or dry
•	130˚C emergency rating
•	250˚C short circuit rating

1

Standard cables are also marked CSA Type RA90,
except four (4) conductor cables which require a different
color code, which may be special-ordered.

SPEC 9500

February, 2011

CCW Armored Control With Grounding Conductor
®

UL Type MC-HL, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
CATALOG
NUMBER

COND.
SIZE
(AWG)

GREEN
NOMINAL
NOMINAL
INSULATED INSULATION
THICKNESS
CORE O.D.
ARMOR O.D.
NO. OF GROUND
COND.
(AWG)
mils mm INCHES mm INCHES mm

CROSS90°C
JACKET
NOMINAL SECTIONAL
APPROXIMATE NET
AMPACITY
THICKNESS OVERALL O.D.
AREA¹
WEIGHT
@ 30°C
mils mm INCHES mm
SQ. IN. LBS/1000 FT kg/1000 m AMBIENT²

14 AWG 7W (2.08 mm²) MULTI-CONDUCTOR CONTROL CABLE WITH GREEN INSULATED GROUNDING CONDUCTOR
9500.01402114

14

2

14

30

0.76 0.30

7.6 0.49 12.4

50

1.27 0.60 15.2

0.29

163

243

15

9500.01403114

14

3

14

30

0.76 0.33

8.4 0.53 13.5

50

1.27 0.64 16.3

0.33

192

286

15

9500.01404114

14

4

14

30

0.76 0.37

9.4 0.58 14.7

50

1.27 0.69 17.5

0.38

222

330

15

9500.01405114

14

5

14

30

0.76 0.39

9.9 0.60 15.2

50

1.27 0.71 18.0

0.40

245

365

15

9500.01406114

14

6

14

30

0.76 0.41 10.4 0.62 15.7

50

1.27 0.73 18.5

0.42

267

397

15

9500.01408114

14

8

14

30

0.76 0.49 12.4 0.71 18.0

50

1.27 0.82 20.8

0.54

321

478

15

9500.01411114

14

11

14

30

0.76 0.57 14.5 0.80 20.3

50

1.27 0.91 23.1

0.66

395

588

12

9500.01418114

14

18

14

30

0.76 0.69 17.5 0.93 23.6

50

1.27 1.04 26.4

0.86

554

824

12

9500.01436114

14

36

14

30

0.76 0.97 24.6 1.24 31.5

50

1.27 1.35 34.3

1.45

948

1,411

10

12 AWG 7W (3.31 mm²) MULTI-CONDUCTOR CONTROL CABLE WITH GREEN INSULATED GROUNDING CONDUCTOR
9500.01202112

12

2

12

30

0.76 0.34

8.6 0.53 13.5

50

1.27 0.64 16.3

0.33

200

298

20

9500.01203112

12

3

12

30

0.76 0.37

9.4 0.58 14.7

50

1.27 0.69 17.5

0.38

239

356

20

9500.01204112

12

4

12

30

0.76 0.45 11.4 0.67 17.0

50

1.27 0.78 19.8

0.48

310

461

20

9500.01205112

12

5

12

30

0.76 0.46 11.7 0.67 17.0

50

1.27 0.78 19.8

0.48

324

482

20

9500.01206112

12

6

12

30

0.76 0.47 11.9 0.67 17.0

50

1.27 0.78 19.8

0.48

338

503

20

9500.01208112

12

8

12

30

0.76 0.56 14.2 0.80 20.3

50

1.27 0.91 23.1

0.66

426

634

20

9500.01211112

12

11

12

30

0.76 0.65 16.5 0.89 22.6

50

1.27 1.00 25.4

0.80

519

772

15

9500.01218112

12

18

12

30

0.76 0.78 19.8 1.02 25.9

50

1.27 1.13 28.7

1.02

739

1,100

15

9500.01236112

12

36

12

30

0.76 1.10 27.9 1.37 34.8

50

1.27 1.48 37.6

1.74

1,302

1,938

12

10 AWG 7W (5.26 mm²) MULTI-CONDUCTOR CONTROL CABLE WITH GREEN INSULATED GROUNDING CONDUCTOR
9500.01002110

10

2

10

30

0.76 0.39

9.9 0.58 14.7

50

1.27 0.69 17.5

0.38

253

377

30

9500.01003110

10

3

10

30

0.76 0.41 10.4 0.62 15.7

50

1.27 0.73 18.5

0.42

303

451

30

9500.01004110

10

4

10

30

0.76 0.45 11.4 0.67 17.0

50

1.27 0.78 19.8

0.48

348

518

30

9500.01006110

10

6

10

30

0.76 0.54 13.7 0.75 19.1

50

1.27 0.86 21.8

0.59

451

671

28

9500.01008110

10

8

10

30

0.76 0.65 16.5 0.89 22.6

50

1.27 1.00 25.4

0.80

568

845

28

9500.01011110

10

11

10

30

0.76 0.75 19.1 0.97 24.6

50

1.27 1.08 27.4

0.93

704

1,048

20

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC Section 392.22.
² Ampacities in accordance with NEC Article 310 and Table 310.15(B)(16).
Note: Standard cables with up to and including six (6) conductors are also marked CSA Type RA90. All others are special order.

Phone: 888-593-3355
www.generalcable.com

SPEC 9510

February, 2011

CCW Armored Control With Bare Grounding Conductor
®

UL Type MC-HL, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Compressed Class B stranding per
ASTM B8
Insulation:
•	Cross-linked Polyethylene (XLPE)
insulation per ICEA S-73-532 and UL
44, Listed XHHW-2
•	Color-coded per ICEA Method 1, Table
E2, full-colored insulation with stripes
•	Color-coded per CSA C22.2 No. 123
where applicable
Grounding Conductor:
•	Class B stranded bare annealed
copper per ASTM B3 and B8
•	Sized in accordance with NEC Table
250.122
Cable Assembly:
•	Insulated conductors and grounding
wire are cabled together with nonhygroscopic fillers when required
•	A binder tape, when required, is
applied over the cabled core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569 and UL 2225
•	CCW armor conductivity meets the
grounding requirements of NEC
Article 250
Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC), black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C
•	Meets CSA Low Acid Gas
requirements

Phone: 888-593-3355
www.generalcable.com

Applications:

Specifications:

•	CCW armored Control cables offer
an economical, rugged and reliable
alternative to labor-intensive cable in
conduit wiring methods
•	For use in Class I, II and III, Divisions
1 and 2; and Class I, Zones 1 and 2
hazardous locations per NEC Articles
501, 502, 503 and 505
•	For use as services, feeders and
branch circuits for power, lighting,
control, and signal circuits in
accordance with NEC Articles 330
and 725
•	Installed indoors or outdoors, wet
or dry locations, directly buried,
embedded in concrete, in a raceway,
as aerial cable on a messenger,
in cable trays, or as exposed runs
secured to supports in accordance
with NEC Article 330
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Design Adherence:
•	ICEA S-73-532/WC57 Standard for
Control, Thermocouple Extension and
Instrumentation Cables
•	UL 44 Rubber Insulated Wires and
Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309 Marine Shipboard Cable
•	CSA C22.2 No. 123 Metal Sheathed
Cables
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type MC-HL, XHHW-2, SUN RES,
CT USE, DIR BUR, -40°C, UL File
# E69797
•	UL Listed Marine Shipboard, UL File
# E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC
•	CSA Certified1 Type RA90, XLPE, SR,
FT4, and -40°C, CSA File # 7319

Features:
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
•	CCW armor provides EMI shielding
performance
•	Factory assembled and tested cable
for use as an alternative to cable in
conduit wiring systems
•	Meets cold impact at -40°C
•	90˚C continuous operating
temperature, wet or dry
•	130˚C emergency rating
•	250˚C short circuit rating

1

Standard cables are also marked CSA Type RA90,
except four (4) conductor cables which require a different
color code, which may be special-ordered.

SPEC 9510

February, 2011

CCW Armored Control With Bare Grounding Conductor
®

UL Type MC-HL, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
BARE
NOMINAL
NOMINAL
COND.
INSULATED INSULATION
THICKNESS
CORE O.D.
ARMOR O.D.
SIZE NO. OF GROUND
(AWG) COND.
(AWG)
mils mm INCHES mm INCHES mm

CATALOG
NUMBER

CROSS90°C
JACKET
NOMINAL SECTIONAL
APPROXIMATE NET
AMPACITY
THICKNESS OVERALL O.D.
AREA¹
WEIGHT
@ 30°C
mils mm INCHES mm
SQ. IN. LBS/1000 FT kg/1000 m AMBIENT²

14 AWG 7W (2.08 mm²) MULTI-CONDUCTOR CONTROL CABLE WITH BARE GROUNDING CONDUCTOR
9510.01404114

14

4

14

30

0.76 0.35

8.8 0.52 13.3

50

1.27 0.63 16.0

0.62

203

302

9510.01405114

14

5

14

30

0.76 0.38

9.7 0.53 13.5

50

1.27 0.63 16.0

0.62

224

333

20

9510.01407114

14

7

14

30

0.76 0.43 10.9 0.60 15.2

50

1.27 0.71 18.0

0.79

287

427

17.5

9510.01409114

14

9

14

30

0.76 0.51 13.0 0.75 19.1

50

1.27 0.86 21.8

1.16

368

548

17.5

9510.01412114

14

12

14

30

0.76 0.56 14.2 0.79 20.1

50

1.27 0.89 22.6

1.24

425

632

12.5

9510.01419114

14

19

14

30

0.76 0.67 17.0 0.92 23.4

50

1.27 1.02 25.9

1.63

594

884

12.5

9510.01437114

14

37

14

30

0.76 0.94 23.9 1.22 31.0

50

1.27 1.32 33.5

2.74

1,030

1,533

20

10

12 AWG 7W (3.31 mm²) MULTI-CONDUCTOR CONTROL CABLE WITH BARE GROUNDING CONDUCTOR
9510.01204112

12

4

12

30

0.76 0.38

9.7 0.55 14.0

50

1.27 0.65 16.5

0.66

246

366

24

9510.01205112

12

5

12

30

0.76 0.43 10.9 0.61 15.5

50

1.27 0.71 18.0

0.79

302

449

24

9510.01207112

12

7

12

30

0.76 0.49 12.4 0.64 16.3

50

1.27 0.74 18.8

0.86

362

539

21

9510.01209112

12

9

12

30

0.76 0.58 14.7 0.79 20.1

50

1.27 0.90 22.9

1.21

458

682

21

9510.012121112

12

12

12

30

0.76 0.64 16.3 0.83 21.1

50

1.27 0.94 23.9

1.39

545

811

15

10 AWG 7W (5.26 mm²) MULTI-CONDUCTOR CONTROL CABLE WITH BARE GROUNDING CONDUCTOR
9510.01004110

10

4

10

30

0.76 0.46 11.7 0.63 16.0

50

1.27 0.73 18.5

0.84

343

510

32

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC Section 392.22.
² Ampacities in accordance with NEC Article 310 and Table 310.15(B)(16).

Phone: 888-593-3355
www.generalcable.com

SPEC 9525

February, 2011

CCW Armored Control Without Grounding Conductor
®

UL Type MC, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Class B stranding per ASTM B8
Insulation:
•	Cross-linked Polyethylene (XLPE)
insulation per ICEA S-73-532 and UL
44, Listed XHHW-2
•	Color-coded per ICEA Method 1, Table
E2, full-colored insulation with stripes
•	Color-coded per CSA C22.2 No. 123
where applicable
Cable Assembly:
•	Insulated conductors are cabled
together with non-hygroscopic fillers
when required
•	A binder tape, when required, is
applied over the cabled core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569
•	CCW armor conductivity meets the
grounding requirements of NEC
Article 250
Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC), black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C
•	Meets CSA Low Acid Gas
requirements

Phone: 888-593-3355
www.generalcable.com

Applications:
•	CCW armored Control cables offer
an economical, rugged and reliable
alternative to labor-intensive cable in
conduit wiring methods
•	For use in Class I and II, Division 2;
Class III, Divisions 1 and 2; and Class
I, Zone 2 hazardous locations per NEC
Articles 501, 502, 503 and 505
•	For use as services, feeders and
branch circuits for power, lighting,
control, and signal circuits in
accordance with NEC Articles 330
and 725
•	Installed indoors or outdoors, wet
or dry locations, directly buried,
embedded in concrete, in a raceway,
as aerial cable on a messenger,
in cable trays, or as exposed runs
secured to supports in accordance
with NEC Article 330
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features: (cont’d)
•	90˚C continuous operating
temperature, wet or dry
•	130˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	ICEA S-73-532/WC57 Standard for
Control, Thermocouple Extension and
Instrumentation Cables
•	UL 44 Rubber Insulated Wires and
Cables
•	UL 1569 Metal Clad Cables
•	UL 1309 Marine Shipboard Cable
•	CSA C22.2 No. 123 Metal Sheathed
Cables
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type MC, XHHW-2, SUN RES,
CT USE, DIR BUR, -40°C, UL File
# E69797
•	UL Listed Marine Shipboard, UL File
# E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC
•	CSA Certified1 Type RA90, XLPE, SR,
FT4, and -40°C, CSA File # 7319

Features:
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
•	CCW armor provides EMI shielding
performance
•	Factory assembled and tested cable
for use as an alternative to cable in
conduit wiring systems
•	Meets cold impact at -40°C
1

Standard cables are also marked CSA Type RA90,
except four (4) conductor cables which require a different
color code, which may be special-ordered.

SPEC 9525

February, 2011

CCW Armored Control Without Grounding Conductor
®

UL Type MC, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
COND.
SIZE
(AWG)

CATALOG
NUMBER

NO.
OF
COND.

INSULATION
THICKNESS
mils

mm

NOMINAL
CORE O.D.
INCHES

mm

NOMINAL
ARMOR O.D.
INCHES

mm

JACKET
THICKNESS
mils

mm

CROSSNOMINAL
SECTIONAL
OVERALL O.D.
AREA¹
INCHES

mm

SQ. IN.

APPROXIMATE
NET WEIGHT

90˚C
AMPACITY @
LBS/1000 FT kg/1000 m 30˚C AMBIENT²

14 AWG 7W (2.08 mm²) MULTI-CONDUCTOR CONTROL CABLE WITHOUT GROUNDING CONDUCTOR
9525.01402000
9525.01403000
9525.01404000
9525.01405000
9525.01407000
9525.01409000
9525.01412000
9525.01419000
9525.01437000

14
14
14
14
14
14
14
14
14

2
3
4
5
7
9
12
19
37

30
30
30
30
30
30
30
30
30

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.28
0.30
0.33
0.37
0.41
0.50
0.57
0.69
0.96

7.1
7.6
8.4
9.4
10.4
12.7
14.5
17.5
24.4

0.49
0.49
0.53
0.58
0.62
0.71
0.80
0.93
1.24

12.4
12.4
13.5
14.7
15.7
18.0
20.3
23.6
31.5

50
50
50
50
50
50
50
50
50

1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27

0.60
0.60
0.64
0.69
0.73
0.82
0.91
1.04
1.35

15.2
15.2
16.3
17.5
18.5
20.8
23.1
26.4
34.3

0.29
0.29
0.33
0.38
0.42
0.54
0.66
0.86
1.45

144
155
183
213
257
312
386
544
959

214
231
273
317
383
465
575
810
1,427

15
15
15
15
15
15
12
12
10

12 AWG 7W (3.31 mm²) MULTI-CONDUCTOR CONTROL CABLE WITHOUT GROUNDING CONDUCTOR
9525.01202000
9525.01203000
9525.01204000
9525.01205000
9525.01207000
9525.01209000
9525.01212000
9525.01219000
9525.01237000

12
12
12
12
12
12
12
12
12

2
3
4
5
7
9
12
19
37

30
30
30
30
30
30
30
30
30

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.31
0.34
0.38
0.42
0.47
0.56
0.65
0.78
1.08

7.9
8.6
9.7
10.7
11.9
14.2
16.5
19.8
27.4

0.53
0.53
0.58
0.62
0.67
0.80
0.89
1.02
1.37

13.5
13.5
14.7
15.7
17.0
20.3
22.6
25.9
34.8

50
50
50
50
50
50
50
50
50

1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27

0.64
0.64
0.69
0.73
0.78
0.91
0.99
1.13
1.48

16.3
16.3
17.5
18.5
19.8
23.1
25.1
28.7
37.6

0.33
0.33
0.38
0.42
0.48
0.66
0.78
1.02
1.74

166
192
229
266
328
410
510
731
1,318

247
285
341
395
489
611
759
1,087
1,962

20
20
20
20
20
20
15
15
12

10 AWG 7W (5.26 mm²) MULTI-CONDUCTOR CONTROL CABLE WITHOUT GROUNDING CONDUCTOR
9525.01002000
9525.01003000
9525.01004000
9525.01005000
9525.01007000
9525.01009000
9525.01012000

10
10
10
10
10
10
10

2
3
4
5
7
9
12

30
30
30
30
30
30
30

0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.36
0.39
0.44
0.48
0.54
0.65
0.74

9.1
9.9
11.2
12.2
13.7
16.5
18.8

0.58
0.58
0.67
0.71
0.75
0.89
0.97

14.7
14.7
17.0
18.0
19.1
22.6
24.6

50
50
50
50
50
50
50

1.27
1.27
1.27
1.27
1.27
1.27
1.27

0.69
0.69
0.78
0.82
0.86
1.00
1.08

17.5
17.5
19.8
20.8
21.8
25.4
27.4

0.38
0.38
0.48
0.54
0.59
0.80
0.93

205
241
301
353
442
551
693

305
359
448
525
658
820
1,032

30
30
30
30
28
28
20

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC ® Section 392.22.
² Ampacities in accordance with NEC ® Article 310 and Table 310.15(B)(16).
Note: Standard cables with up to and including six (6) conductors are also marked CSA Type RA90. All others are special order.

Phone: 888-593-3355
www.generalcable.com

SPEC 9600

February, 2011

CCW Armored Power, 3/C VFD and 4/C
®

UL Type MC-HL, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
•	Bare annealed copper per ASTM B3
•	10 AWG and smaller are Class B
compressed stranding per ASTM B8
•	8 AWG and larger are compact
stranding per ASTM B496
Insulation:
•	Cross-linked Polyethylene (XLPE)
insulation per ICEA S-95-658 and UL
44, Listed XHHW-2
•	6 AWG and smaller are color-coded
per ICEA Method 1, Table E2
•	4 AWG and larger are black with
printed numbers per ICEA Method 4
•	Color-coded per CSA C22.2 No. 123
where applicable
Grounding Conductor(s):
•	Class B stranded bare annealed
copper per ASTM B3 and B8
•	Where specified, single or three
split grounding wires are sized in
accordance with NEC Table 250.122
Cable Assembly:
•	Insulated conductors and grounding
wire(s) are cabled together with nonhygroscopic fillers when required
•	A binder tape is applied over the
cabled core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569 and UL 2225
•	CCW armor conductivity meets the
grounding requirements of NEC
Article 250
Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC), black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C
•	Meets CSA Low Acid Gas
requirements

Phone: 888-593-3355
www.generalcable.com

Applications:
•	Variable Frequency Drives:
3-conductor CCW armored cables
with three (3) symmetrical grounding
wires are the preferred wiring method
for use with AC motors controlled by
pulse-width modulated inverters in
VFD applications
•	CCW armored cables offer an
economical, rugged and reliable
alternative to labor-intensive cable in
conduit wiring methods
•	For use in Class I, II and III, Divisions
1 and 2; and Class I, Zones 1 and 2
hazardous locations per NEC Articles
501, 502, 503 and 505
•	For use as services, feeders and
branch circuits for power, lighting,
control, and signal circuits in
accordance with NEC Articles 330
and 725
•	Installed indoors or outdoors, wet
or dry locations, directly buried,
embedded in concrete, in a raceway,
as aerial cable on a messenger,
in cable trays, or as exposed runs
secured to supports in accordance
with NEC Article 330
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	3-conductor CCW power cables
with three grounding wires are
recommended for use with pulse-width
modulated AC drives
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
•	CCW armor provides EMI shielding
performance
•	Factory assembled and tested cable
for use as an alternative to cable in
conduit wiring systems

Features: (cont’d)
•	Meets cold impact at -40°C
•	90˚C continuous operating
temperature, wet or dry
•	130˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	ICEA S-95-658/WC70 Standard for
Nonshielded Power Cable, 2 kV
or Less
•	UL 44 Rubber Insulated Wires
and Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309 Marine Shipboard Cable
•	CSA C22.2 No. 123 Metal Sheathed
Cables
•	CSA C22.2 No. 174 Cables and Cable
Glands for Use in Hazardous Locations
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type MC-HL, XHHW-2, SUN RES,
CT USE, DIR BUR, -40°C, UL File
# E69797
•	UL Listed Marine Shipboard, UL File
# E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC
•	CSA Certified Type RA90, XLPE,
HL, SR, FT4, and -40°C, CSA File
# 7319
1

Standard cables are also marked CSA Type RA90,
except four (4) conductor cables which require a different
color code, which may be special-ordered.

SPEC 9600

February, 2011

CCW Armored Power, 3/C VFD and 4/C
®

UL Type MC-HL, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
CATALOG
NUMBER
9600.01403318

INSULATION
COND.
SIZE
NO. OF THICKNESS
(AWG/kcmil) COND. mils mm

NOMINAL
NOMINAL
BARE
CORE O.D.
ARMOR O.D.
GROUND
(AWG) INCHES mm INCHES mm

CROSS90°C
JACKET
NOMINAL SECTIONAL APPROXIMATE NET AMPACITY
THICKNESS OVERALL O.D. AREA¹
WEIGHT
@ 30°C
mils mm INCHES mm
SQ. IN. LBS/1000 FT kg/1000 m AMBIENT²

14 (7/W)
(2.08 mm²)

3

30

0.76 3 x #18 0.33

8.4

0.53

13.5

50

1.27

0.64

16.3

0.33

163

242

15

4

30

0.76 3 x #18 0.37

9.4

0.58

14.7

50

1.27

0.69

17.5

0.38

226

336

15

12 (7/W)
(3.31 mm²)

3

30

0.76 3 x #16 0.37

9.4

0.58

14.7

50

1.27

0.69

17.5

0.38

243

362

20

4

30

0.76 3 x #16 0.45

11.4

0.67

17.0

50

1.27

0.78

19.8

0.48

291

433

20

10 (7/W)
(5.26 mm²)

3

30

0.76 3 x #14 0.41

10.4

0.62

15.7

50

1.27

0.73

18.5

0.42

305

454

30

4

30

0.76 3 x #14 0.45

11.4

0.67

17.0

50

1.27

0.78

19.8

0.48

354

527

30

8 (7/W)
(8.36 mm²)

3

45

1.14 3 x #14 0.50

12.7

0.71

18.0

50

1.27

0.81

20.6

0.52

392

583

55

4

45

1.14 1 x #10 0.58

14.7

0.80

20.3

50

1.27

0.90

22.9

0.64

473

704

44

6 (7/W)
(13.3 mm²)

3

45

1.14 3 x #12 0.58

14.7

0.80

20.3

50

1.27

0.90

22.9

0.64

534

795

75

4

45

1.14

0.66

16.8

0.89

22.6

50

1.27

0.99

25.1

0.78

641

954

60

4 (7/W)
(21.2 mm²)

3

45

1.14 3 x #12 0.68

17.3

0.89

22.6

50

1.27

0.99

25.1

0.78

716

1,066

95

4

45

1.14

0.77

19.6

0.97

24.6

50

1.27

1.08

27.4

0.93

860

1,280

76

2 (7/W)
(33.6 mm²)

3

45

1.14 3 x #10 0.80

20.3

1.02

25.9

50

1.27

1.13

28.7

1.02

1,013

1,507

130

4

45

1.14

0.92

23.4

1.15

29.2

50

1.27

1.26

32.0

1.26

1,267

1,885

104

1 (19/W)
(42.4 mm²)

3

55

1.40 3 x #10 0.92

23.4

1.15

29.2

50

1.27

1.26

32.0

1.26

1,119

1,666

150

4

55

1.40

1.04

26.4

1.29

32.8

50

1.27

1.40

35.6

1.56

1,526

2,272

120

1/0 (19/W)
(53.5 mm²)

3

55

1.40 3 x #10 1.00

25.4

1.24

31.5

50

1.27

1.34

34.0

1.43

1,496

2,226

170

4

55

1.40

1.12

28.4

1.37

34.8

50

1.27

1.48

37.6

1.74

1,862

2,771

136

2/0 (19/W)
(67.4 mm²)

3

55

1.40 3 x #10 1.09

27.7

1.34

34.0

50

1.27

1.44

36.6

1.65

1,801

2,681

195

4

55

1.40

1 x #6

1.23

31.2

1.51

38.4

60

1.52

1.64

41.7

2.14

2,351

3,498

156

3/0 (19/W)
(85.0 mm²)

3

55

1.40

3 x #8

1.21

30.7

1.47

37.3

60

1.52

1.58

40.1

1.99

2,262

3,367

225

4

55

1.40

1 x #4

1.36

34.5

1.65

41.9

60

1.52

1.78

45.2

2.52

2,921

4,346

180

4/0 (19/W)
(107 mm²)

3

55

1.40

3 x #8

1.33

33.8

1.60

40.6

60

1.52

1.73

43.9

2.38

2,722

4,051

260

4

55

1.40

1 x #4

1.49

37.8

1.78

45.2

60

1.52

1.91

48.5

2.90

3,491

5,194

208

250 (37/W)
(127 mm²)

3

65

1.65

3 x #8

1.48

37.6

1.74

44.2

60

1.52

1.87

47.5

—

3,195

4,755

290

4

65

1.65

1 x #4

1.64

41.7

1.96

49.8

60

1.52

2.09

53.1

—

4,142

6,164

232

350 (37/W)
(177 mm²)

3

65

1.65

3 x #7

1.66

42.2

1.96

49.8

60

1.52

2.09

53.1

—

4,284

6,376

350

4

65

1.65

1 x #3

1.89

48.0

2.19

55.6

75

1.91

2.35

59.7

—

5,536

8,238

280

500 (37/W)
(253 mm²)

3

65

1.65

3 x #6

1.94

49.3

2.28

57.9

75

1.91

2.44

62.0

—

6,035

8,981

430

4

65

1.65

1 x #2

2.14

54.4

2.49

63.2

75

1.91

2.65

67.3

—

7,704

11,464

344

750 (61/W)
(380 mm²)

3

80

2.03

3 x #5

2.37

60.2

2.75

69.9

75

1.91

2.92

74.2

—

8,854

13,176

535

4

80

2.03

1 x #1

2.61

66.3

3.03

77.0

85

2.16

3.21

81.5

—

11,449

17,037

428

9600.100031110 1000 (61/W)
9600.100041110 (507 mm²)

3

80

2.03 1 x #1/0 2.67

67.8

3.11

79.0

85

2.16

3.30

83.8

—

11,611

17,280

615

4

80

2.03 1 x #1/0 3.07

78.0

3.63

92.2

85

2.16

3.81

96.8

—

15,377

22,883

492

9600.01404318
9600.01203316
9600.01204316
9600.01003314
9600.01004314
9600.00803314
9600.00804110
9600.00603312
9600.00604108
9600.00403312
9600.00404108
9600.00203310
9600.00204106
9600.00103310
9600.00104106
9600.11003310
9600.11004106
9600.21003310
9600.21004106
9600.31003308
9600.31004104
9600.41003308
9600.41004104
9600.25003308
9600.25004104
9600.35003307
9600.35004103
9600.50003306
9600.50004102
9600.75003305
9600.75004101

1 x #8

1 x #8

1 x #6

1 x #6

1 x #6

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC Section 392.22.
² Ampacities in accordance with NEC Article 310 and Table 310.15(B)(16).
Note: Three (3) conductors, 6 AWG and smaller are also marked CSA Type RA90. One (1) AWG and larger are also marked CSA Type RA90.

Phone: 888-593-3355
www.generalcable.com

SPEC 9615

September, 2013

CCW Armored Power, 3/C VFD
®

UL Type MC-HL, XLPE, 2000 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	10 AWG and smaller are Class B
compressed stranding per ASTM B8
•	8 AWG and larger are compact
standing per ASTM B496
Insulation:
•	Cross-Linked Polyethylene (XLPE)
insulation, 2000 V thicknesses per
ICEA S-95-658
•	Color-coded black with printed
numbers per ICEA Method 4
Grounding Conductors:
•	Class B stranded bare annealed
copper per ASTM B3 and B8
•	Three (3) split grounding wires
per specification 9615 exceed the
minimum required in NEC Table
250.122
Cable Assembly:
•	Insulated conductors and grounding
wires are cabled together with nonhygroscopic fillers when required
•	A binder tape is applied over the
cabled core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569 and UL 2225
•	CCW armor conductivity meets the
grounding requirements of NEC 	
Article 250
Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC) — Black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Phone: 888-593-3355
www.generalcable.com

Applications:
•	Variable Frequency Drives:
3-conductor CCW armored cables
with three (3) symmetrical grounding
wires is the preferred wiring method
for use with AC motors controlled by
pulse-width modulated Inverters in
VFD applications
•	CCW armored cables offer an
economical, rugged and reliable
alternative to labor-intensive cable in
conduit wiring methods
•	For use in Class I, II and III, Divisions
1 and 2; and Class I, Zones 1 and 2
hazardous locations per NEC Articles
501, 502 and 503
•	For use as services, feeders and
branch circuits for power, lighting,
control, and signal circuits in
accordance with NEC Articles 330 	
and 725
•	Installed indoors or outdoors, wet
or dry locations, directly buried,
embedded in concrete, in a raceway,
as aerial cable on a messenger,
in cable trays, or as exposed runs
secured to supports in accordance
with NEC Article 330
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	90°C, 2000V rated XLPE insulation
with a dielectric constant less than 3.0
to withstand momentary voltage spikes
common in certain VFD applications
•	Three (3) oversized, symmetrical
grounding wires recommended for use
with pulse-width modulated AC drives
•	CCW armor provides an impervious
barrier to moisture, gas and liquids

Features: (cont’d)
•	CCW armor provides EMI shielding
performance
•	Factory assembled and tested cable
for use as an alternative to cable in
conduit wiring systems
•	Meets cold impact at -40°C
•	90˚C continuous operating
temperature, wet or dry
•	130˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	ICEA S-95-658/WC-70 Standard 	
for Non-Shielded Power Cable, 2 kV
or Less
•	UL 44 Rubber Insulated Wires and
Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309 Marine Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 332-3 Cat. A
Compliances:
•	UL Type MC-HL, SUN RES, CT USE,
DIR BUR, -40°C, UL File # E69797
•	UL Listed Marine Shipboard, UL File 	
# E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9615

September, 2013

CCW Armored Power, 3/C VFD
®

UL Type MC-HL, XLPE, 2000 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
INSULATION
NO. OF THICKNESS
COND. mils mm

NOMINAL
NOMINAL
BARE
CORE O.D.
ARMOR O.D.
GROUND
(AWG) INCHES mm INCHES mm

90°C
JACKET
NOMINAL
APPROXIMATE NET AMPACITY
THICKNESS OVERALL O.D.
WEIGHT
@ 30°C
mils mm INCHES mm LBS/1000 FT kg/1000 m AMBIENT¹

CATALOG
NUMBER

COND.
SIZE
(AWG/kcmil)

9615.01403318

14 (7/W) (2.08 mm²)

3

60

1.52

3 x #18

0.44

11.1

0.62 15.2

50

1.27

0.73

17.9

267

397

15

9615.01203316

12 (7/W) (3.31 mm²)

3

60

1.52

3 x #16

0.47

11.9

0.66 16.2

50

1.27

0.77

18.9

324

482

20

9615.01003314

10 (7/W) (5.26 mm²)

3

60

1.52

3 x #14

0.53 13.3

0.73

17.8

50

1.27 0.84 20.5

400

595

30

9615.00803314

8 (7/W) (8.36 mm²)

3

70

1.78

3 x #14

0.65 16.5 0.86

21.1

50

1.27

0.97 23.8

524

780

55

9615.00603312

6 (7/W) (13.3 mm²)

3

70

1.78

3 x #12

0.71

18.0 0.96 23.4

50

1.27

1.07

26.1

697

1,037

75

9615.00403312

4 (7/W) (21.2 mm²)

3

70

1.78

3 x #12

0.81 20.6

1.09

26.6

50

1.27

1.23

30.1

1,000

1,488

95

9615.00203310

2 (7/W) (33.6 mm²)

3

70

1.78

3 x #10

0.94 23.9

1.25

30.6

50

1.27

1.36 33.3

1,285

1,912

130

9615.00103310

1 (19/W) (42.4 mm²)

3

90

2.29 3 x #10

1.13

28.7

1.48

36.1

50

1.27

1.59 38.8

1,595

2,374

150

9615.11003310 1/0 (19/W) (53.5 mm²)

3

90

2.29 3 x #10

1.21

30.6 1.55 38.0

60

1.52

1.68

41.2

1,930

2,872

170

9615.21003306 2/0 (19/W) (67.4 mm²)

3

90

2.29

3 x #6

1.30

32.9

1.68

41.0

60

1.52

1.81

44.2

2,507

3,731

195

9615.41003304 4/0 (19/W) (107 mm²)

3

90

2.29

3 x #4

1.53

38.7

1.91

46.7

60

1.52

2.04 49.9

3,590

5,342

260

9615.25003304 250 (37/W) (127 mm²)

3

105

2.67

3 x #4

1.71

43.4

2.12

51.8

60

1.52

2.25

55.1

4,150

6,176

290

9615.35003302 350 (37/W) (177 mm²)

3

105

2.67

3 x #2

1.93 48.9

2.41

58.9

75

1.91

2.57 62.8

5,214

7,759

350

9615.50003301 500 (37/W) (253 mm²)

3

105

2.67

3 x #1

2.20 55.8 2.68 65.5

75

1.91

2.84 69.5

6,977

10,382

430

Dimensions and weights are nominal; subject to industry tolerances.
¹ Ampacities in accordance with NEC Article 310 and Table 310.15(B)(16).

Phone: 888-593-3355
www.generalcable.com

SPEC 9625

January, 2011

CCW Armored Composite Power and Control
®

UL Type MC-HL, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	10 AWG and smaller are Class B
compressed stranding per ASTM B8
•	8 AWG and larger are compact
stranding per ASTM B496
Insulation:
•	Cross-linked Polyethylene (XLPE)
insulation per ICEA S-95-658 and UL
44, Listed XHHW-2
•	Power conductors 6 AWG and smaller
are color-coded per ICEA Method 1,
Table E2
•	Power conductors 4 AWG and larger
are black with printed numbers per
ICEA Method 4
•	Control conductors are color-coded
black, red, blue and yellow
Grounding Conductor:
•	Class B stranded bare annealed
copper per ASTM B3 and B8
•	Sized in accordance with NEC Table
250.122
Cable Assembly:
•	Insulated conductors and grounding
wire are cabled together with nonhygroscopic fillers when required
•	A binder tape is applied over the
cabled core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569 and UL 2225
•	CCW armor conductivity meets the
grounding requirements of NEC
Article 250

Phone: 888-593-3355
www.generalcable.com

Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC), black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored Composite Power and
Control cables offer an economical,
rugged and reliable alternative to
labor-intensive cable in conduit wiring
methods
•	For use in Class I, II and III, Divisions
1 and 2; and Class I, Zones 1 and 2
hazardous locations per NEC Articles
501, 502, 503 and 505
•	For use as services, feeders and
branch circuits for power, lighting,
control, and signal circuits in
accordance with NEC Articles 330
and 725
•	Installed indoors or outdoors, wet
or dry locations, directly buried,
embedded in concrete, in a raceway,
as aerial cable on a messenger,
in cable trays, or as exposed runs
secured to supports in accordance
with NEC Article 330
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
•	CCW armor provides EMI shielding
performance
•	Factory assembled and tested cable
for use as an alternative to cable in
conduit wiring systems
•	Meets cold impact at -40°C
•	90˚C continuous operating
temperature, wet or dry
•	130˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	ICEA S-95-658/WC70 Standard
for Nonshielded Power Cables,
2 kV or Less
•	UL 44 Rubber Insulated Wires and
Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309 Marine Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type MC-HL, XHHW-2, SUN RES,
CT USE, DIR BUR, -40°C, UL File
# E69797
•	UL Listed Marine Shipboard, UL File
# E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9625

January, 2011

CCW Armored Composite Power and Control
®

UL Type MC-HL, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
CATALOG
NUMBER

POWER CONTROL CONTROL
CROSS90°C
INSULATION BARE
NOMINAL
NOMINAL
JACKET
NOMINAL SECTIONAL APPROXIMATE NET AMPACITY
POWER INSULATION
COND.
THICKNESS
THICKNESS
CORE
O.D.
ARMOR
O.D.
THICKNESS
OVERALL
O.D.
AREA¹
WEIGHT
COND. SIZE
SIZE
GROUNDING
@ 30°C
(AWG)
mils mm (AWG) mils mm
(AWG) INCHES mm INCHES mm mils mm INCHES mm SQ. IN. LBS/1000 FT kg/1000 m AMBIENT²

(7/W)
9625.103124110 3x#10
(5.26 mm²) 30 0.76
(7/W)
9625.083124110 3x#8
(8.36 mm²)

45 1.14

(7/W)
9625.063124108 3x#6
(13.3 mm²)

45 1.14

(7/W)
9625.043124108 3x#4
(21.2 mm²)

45 1.14

30 0.76

0.53 13.5 0.75 19.1 50 1.27 0.86 21.8

0.59

430

640

30

0.65 16.5 0.89 22.6 50 1.27 0.99 25.1

0.78

535

796

55

0.69 17.5 0.93 23.6 50 1.27 1.03 26.2

0.84

660

982

75

0.74 18.8 0.97 24.6 50 1.27 1.08 27.4

0.93

815

1,213

95

10 (7/W)
(5.2 mm²)
4 x #12
(7/W)
(3.31 mm²)

30 0.76
30 0.76
8 (7/W)
(8.36 mm²)
30 0.76

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC Section 392.22.
² Ampacities in accordance with NEC Article 310 and Table 310.15(B)(16).  

Phone: 888-593-3355
www.generalcable.com

SPEC 9650

February, 2011

CCW Armored Composite Power and Control Without Ground
®

UL Type MC, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Sizes 10 AWG and smaller are Class B
compressed stranding per ASTM B8
•	Sizes 8 AWG and larger are compact
stranding per ASTM B496
Insulation:
•	Cross-linked Polyethylene (XLPE)
insulation per ICEA S-95-658 and
UL 44, Listed XHHW-2
•	Power conductors sizes 6 AWG and
smaller are color-coded per ICEA
Method 1, Table E2
•	Power conductors sizes 4 AWG and
larger are black with printed numbers
per ICEA Method 4
•	Control conductors are color-coded
black, red, blue and yellow
Cable Assembly:
•	Insulated conductors are cabled
together with non-hygroscopic fillers
when required
•	A binder tape, when required, is
applied over the cabled core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1569
•	CCW armor conductivity meets the
grounding requirements of NEC
Article 250
Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC), black
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Phone: 888-593-3355
www.generalcable.com

Applications:
•	CCW armored Composite Power and
Control cables offer an economical,
rugged and reliable alternative to
labor-intensive cable in conduit wiring
methods
•	For use in Class I and II, Division 2;
Class III, Divisions 1 and 2; and Class
I, Zone 2 hazardous locations per NEC
Articles 501, 502, 503 and 505
•	For use as services, feeders and
branch circuits for power, lighting,
control, and signal circuits in
accordance with NEC Articles 330
and 725
•	Installed indoors or outdoors, wet
or dry locations, directly buried,
embedded in concrete, in a raceway,
as aerial cable on a messenger,
in cable trays, or as exposed runs
secured to supports in accordance
with NEC Article 330
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
•	CCW armor provides EMI shielding
performance
•	Factory assembled and tested cable
for use as an alternative to cable in
conduit wiring systems

Features: (cont’d)
•	Meets cold impact at -40°C
•	90˚C continuous operating
temperature, wet or dry
•	130˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	ICEA S-95-658/WC70 Standard
for Nonshielded Power Cable, 2 kV
or Less
•	UL 44 Rubber Insulated Wires and
Cables
•	UL 1569 Metal Clad Cables
•	UL 1309 Marine Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1581 (70,000 BTU/hr)
•	IEC 60332-3 Cat. A
Compliances:
•	UL Type MC, XHHW-2, SUN RES,
CT USE, DIR BUR, -40°C, UL File #
E69797
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9650

February, 2011

CCW Armored Composite Power and Control Without Ground
®

UL Type MC, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant, Direct Burial
UL Marine Shipboard Cable, ABS CWCMC
CATALOG
NUMBER

POWER
CONTROL
CROSS90°C
INSULATION CONTROL COND. INSULATION NOMINAL
NOMINAL
JACKET
NOMINAL SECTIONAL APPROXIMATE NET AMPACITY
THICKNESS
THICKNESS
CORE
O.D.
ARMOR
O.D.
THICKNESS
OVERALL
O.D.
AREA¹
WEIGHT
POWER COND. SIZE
SIZE
@ 30°C
(AWG)
mils mm
(AWG)
mils mm INCHES mm INCHES mm mils mm INCHES mm SQ. IN. LBS/1000 FT kg/1000 m AMBIENT²

9650.123143000 3x#12 (7/W) (3.31 mm²) 30 0.76 3x#14 (7/W) (2.08 mm²) 30 0.76 0.49 12.4 0.71 18.0 50 1.27 0.82 20.8

0.54

307

457

20

9650.123144000 3x#12 (7/W) (3.31 mm²) 30 0.76 4x#14 (7/W) (2.08 mm²) 30 0.76 0.49 12.4 0.71 18.0 50 1.27 0.82 20.8

0.54

323

481

20

9650.124143000 4x#12 (7/W) (3.31 mm²) 30 0.76 3x#14 (7/W) (2.08 mm²) 30 0.76 0.49 12.4 0.71 18.0 50 1.27 0.82 20.8

0.54

365

543

20

9650.124144000 4x#12 (7/W) (3.31 mm²) 30 0.76 4x#14 (7/W) (2.08 mm²) 30 0.76 0.53 13.5 0.75 19.1 50 1.27 0.86 21.8

0.59

388

577

20

9650.103143000 3x#10 (7/W) (5.26 mm²) 30 0.76 3x#14 (7/W) (2.08 mm²) 30 0.76 0.53 13.5 0.75 19.1 50 1.27 0.86 21.8

0.59

384

571

30

9650.103144000 3x#10 (7/W) (5.26 mm²) 30 0.76 4x#14 (7/W) (2.08 mm²) 30 0.76 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1

0.66

392

583

30

9650.103123000 3x#10 (7/W) (5.26 mm²) 30 0.76 3x#12 (7/W) (3.31 mm²) 30 0.76 0.53 13.5 0.75 19.1 50 1.27 0.86 21.8

0.59

410

610

30

9650.104143000 4x#10 (7/W) (5.26 mm²) 30 0.76 3x#14 (7/W) (2.08 mm²) 30 0.76 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1

0.66

412

613

30

9650.104144000 4x#10 (7/W) (5.26 mm²) 30 0.76 4x#14 (7/W) (2.08 mm²) 30 0.76 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1

0.66

428

637

30

9650.104123000 4x#10 (7/W) (5.26 mm²) 30 0.76 3x#12 (7/W) (3.31 mm²) 30 0.76 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1

0.66

436

649

30

9650.104124000 4x#10 (7/W) (5.26 mm²) 30 0.76 4x#12 (7/W) (3.31 mm²) 30 0.76 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1

0.66

460

685

30

9650.083143000 3x#8 (7/W) (8.36 mm²) 45 1.14 3x#14 (7/W) (2.08 mm²) 30 0.76 0.58 14.7 0.80 20.3 50 1.27 0.91 23.1

0.66

424

631

55

9650.083144000 3x#8 (7/W) (8.36 mm²) 45 1.14 4x#14 (7/W) (2.08 mm²) 30 0.76 0.62 15.7 0.84 21.3 50 1.27 0.91 23.1

0.66

455

677

55

9650.083123000 3x#8 (7/W) (8.36 mm²) 45 1.14 3x#12 (7/W) (3.31 mm²) 30 0.76 0.58 14.7 0.80 20.3 50 1.27 0.95 24.1

0.72

455

677

55

9650.083124000 3x#8 (7/W) (8.36 mm²) 45 1.14 4x#12 (7/W) (3.31 mm²) 30 0.76 0.62 15.7 0.84 21.3 50 1.27 0.91 23.1

0.66

495

737

55

9650.084143000 4x#8 (7/W) (8.36 mm²) 45 1.14 3x#14 (7/W) (2.08 mm²) 30 0.76 0.62 15.7 0.84 21.3 50 1.27 0.95 24.1

0.72

505

752

44

9650.084144000 4x#8 (7/W) (8.36 mm²) 45 1.14 4x#14 (7/W) (2.08 mm²) 30 0.76 0.67 17.0 0.89 22.6 50 1.27 1.00 25.4

0.80

530

789

44

9650.084123000 4x#8 (7/W) (8.36 mm²)

45 1.14 3x#12 (7/W) (3.31 mm²) 30 0.76 0.67 17.0 0.89 22.6 50 1.27 1.00 25.4

0.80

535

796

44

9650.084124000 4x#8 (7/W) (8.36 mm²) 45 1.14 4x#12 (7/W) (3.31 mm²) 30 0.76 0.71 18.0 0.93 23.6 50 1.27 1.04 26.4

0.86

576

857

44

9650.063143000 3x#6 (7/W) (13.3 mm²) 45 1.14 3x#14 (7/W) (2.08 mm²) 30 0.76 0.62 15.7 0.84 21.3 50 1.27 0.95 24.1

0.72

525

781

75

9650.063144000 3x#6 (7/W) (13.3 mm²) 45 1.14 4x#14 (7/W) (2.08 mm²) 30 0.76 0.62 15.7 0.84 21.3 50 1.27 0.95 24.1

0.72

545

811

75

9650.063123000 3x#6 (7/W) (13.3 mm²) 45 1.14 3x#12 (7/W) (3.31 mm²) 30 0.76 0.62 15.7 0.84 21.3 50 1.27 0.95 24.1

0.72

556

827

75

9650.063124000 3x#6 (7/W) (13.3 mm²) 45 1.14 4x#12 (7/W) (3.31 mm²) 30 0.76 0.71 18.0 0.93 23.6 50 1.27 1.03 26.2

0.84

606

902

75

9650.064143000 4x#6 (7/W) (13.3 mm²) 45 1.14 3x#14 (7/W) (2.08 mm²) 30 0.76 0.71 18.0 0.93 23.6 50 1.27 1.04 26.4

0.86

657

978

60

9650.064144000 4x#6 (7/W) (13.3 mm²) 45 1.14 4x#14 (7/W) (2.08 mm²) 30 0.76 0.71 18.0 0.93 23.6 50 1.27 1.04 26.4

0.86

667

993

60

9650.064123000 4x#6 (7/W) (13.3 mm²)

45 1.14 3x#12 (7/W) (3.31 mm²) 30 0.76 0.75 19.1 0.97 24.6 50 1.27 1.08 27.4

0.93

687

1,022

60

9650.064124000 4x#6 (7/W) (13.3 mm²) 45 1.14 4x#12 (7/W) (3.31 mm²) 30 0.76 0.75 19.1 0.97 24.6 50 1.27 1.08 27.4

0.93

717

1,067

60

9650.043143000 3x#4 (7/W) (21.2 mm²) 45 1.14 3x#14 (7/W) (2.08 mm²) 30 0.76 0.71 18.0 0.93 23.6 50 1.27 1.04 26.4

0.86

707

1,052

95

9650.043144000 3x#4 (7/W) (21.2 mm²) 45 1.14 4x#14 (7/W) (2.08 mm²) 30 0.76 0.71 18.0 0.93 23.6 50 1.27 1.04 26.4

0.86

727

1,082

95

9650.043123000 3x#4 (7/W) (21.2 mm²) 45 1.14 3x#12 (7/W) (3.31 mm²) 30 0.76 0.71 18.0 0.93 23.6 50 1.27 1.04 26.4

0.86

727

1,082

95

9650.043124000 3x#4 (7/W) (21.2 mm²) 45 1.14 4x#12 (7/W) (3.31 mm²) 30 0.76 0.75 19.1 0.97 24.6 50 1.27 1.08 27.4

0.93

768

1,143

95

9650.044143000 4x#4 (7/W) (21.2 mm²) 45 1.14 3x#14 (7/W) (2.08 mm²) 30 0.76 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7

1.09

899

1,338

76

9650.044144000 4x#4 (7/W) (21.2 mm²) 45 1.14 4x#14 (7/W) (2.08 mm²) 30 0.76 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7

1.09

929

1,383

76

9650.044123000 4x#4 (7/W) (21.2 mm²)

45 1.14 3x#12 (7/W) (3.31 mm²) 30 0.76 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7

1.09

929

1,383

76

9650.044124000 4x#4 (7/W) (21.2 mm²) 45 1.14 4x#12 (7/W) (3.31 mm²) 30 0.76 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7

1.09

960

1,429

76

9650.023143000 3x#2 (7/W) (33.6 mm²) 45 1.14 3x#14 (7/W) (2.08 mm²) 30 0.76 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7

1.09

995

1,481

130

9650.023144000 3x#2 (7/W) (33.6 mm²) 45 1.14 4x#14 (7/W) (2.08 mm²) 30 0.76 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7

1.09

1,010

1,503

130

9650.023123000 3x#2 (7/W) (33.6 mm²) 45 1.14 3x#12 (7/W) (3.31 mm²) 30 0.76 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7

1.09

1,020

1,518

130

9650.023124000 3x#2 (7/W) (33.6 mm²) 45 1.14 4x#12 (7/W) (3.31 mm²) 30 0.76 0.81 20.6 1.06 26.9 50 1.27 1.17 29.7

1.09

1,050

1,563

130

9650.024143000 4x#2 (7/W) (33.6 mm²) 45 1.14 3x#14 (7/W) (2.08 mm²) 30 0.76 0.90 22.9 1.15 29.2 50 1.27 1.26 32.0

1.26

1,242

1,848

104

9650.024144000 4x#2 (7/W) (33.6 mm²) 45 1.14 4x#14 (7/W) (2.08 mm²) 30 0.76 0.90 22.9 1.15 29.2 50 1.27 1.26 32.0

1.26

1,263

1,880

104

9650.024123000 4x#2 (7/W) (33.6 mm²)

45 1.14 3x#12 (7/W) (3.31 mm²) 30 0.76 0.90 22.9 1.15 29.2 50 1.27 1.26 32.0

1.26

1,273

1,894

104

9650.024124000 4x#2 (7/W) (33.6 mm²) 45 1.14 4x#12 (7/W) (3.31 mm²) 30 0.76 0.90 22.9 1.15 29.2 50 1.27 1.26 32.0

1.26

1,293

1,924

104

Dimensions and weights are nominal; subject to industry tolerances.
¹ Cross-sectional area for cable tray fill is in accordance with NEC Section 392.22.
² Ampacities in accordance with NEC Article 310 and Table 310.15(B)(16).  

Phone: 888-593-3355
www.generalcable.com

SPEC 9675

March, 2012

CCW Armored Power, 1000 V, 3/C VFD
®

CSA Type RA90, XLPE, 1000 V, 90°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, FT4, -40°C, AG14, HL

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Sizes 10 AWG and smaller are Class B
compressed stranding per ASTM B8
•	Sizes 8 AWG and larger are compact
stranding per ASTM B496
Insulation:
•	Cross-linked Polyethylene (XLPE)
insulation rated 1000 Volts, RW90 per
CSA C22.2 No. 38
•	Sizes 2 AWG and smaller utilize a
single color insulation: black, red
and blue
•	Sizes 1 AWG and larger utilize black
insulation with printed number/color,
1-black, 2-red, 3-blue
Bonding/Grounding Conductors:
•	Class B stranded bare annealed
copper per ASTM B3 and B8
•	Three (3) symmetrical grounding wires
are sized in accordance with CEC
Table 16
Cable Assembly:
•	Three symmetrical grounding wires
are cabled within the interstices of the
phase conductors
•	Non-hygroscopic fillers when required
•	A binder tape is applied over the
cabled core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
C22.2 No. 123

Phone: 888-593-3355
www.generalcable.com

Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC), black
•	Meets CSA Low Gas Emission
requirements, AG14

Applications:
•	Variable Frequency Drives:
3-conductor CCW armored cables
with three (3) symmetrical grounding
wires are the preferred wiring method
for use with AC motors controlled by
pulse-width modulated inverters in
VFD applications
•	CCW armored cables offer an
economical, rugged and reliable
alternative to labor-intensive cable in
conduit wiring methods
•	For use in industrial and commercial
installations including hazardous
locations in accordance with the CEC
•	Can be installed in wet or dry
locations, indoors or outdoors, in cable
trays, in a raceway, or direct buried in
accordance with the CEC

Features:
•	90°C, 1000 V wet or dry XLPE
insulation and three (3) symmetrical
grounding wires, recommended
for use with pulse-width modulated
AC drives
•	XLPE insulation has a dielectric
constant less than 3.0 to withstand
momentary voltage spikes common
with VFD applications

Features: (cont’d)
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
•	CCW armor provides EMI shielding
performance
•	Factory assembled and tested cable
for use as an alternative to cable in
conduit wiring systems
•	Meets cold impact at -40°C
•	90˚C continuous operating
temperature, wet or dry
•	130˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	CSA C22.2 No. 38 ThermosetInsulated Wires and Cables
•	CSA C22.2 No. 123 Metal Sheathed
Cables
•	CSA C22.2 No. 174 Cables and Cable
Glands for Use in Hazardous Locations
Flame Tests:
•	CSA FT4
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	IEEE 1202 (70,000 BTU/hr)
Compliances:
•	CSA Certified Type RA90, XLPE,
HL, SR, FT4, AG14 and -40°C,
CSA File # 7319

SPEC 9675

March, 2012

CCW Armored Power, 1000 V, 3/C VFD
®

CSA Type RA90, XLPE, 1000 V, 90°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, FT4, -40°C, AG14, HL
CATALOG
NUMBER

COND.
SIZE
(AWG
(kcmil)

INSULATION
NO. OF THICKNESS
COND. mils mm

BARE
90°C
NOMINAL
NOMINAL
JACKET
NOMINAL
APPROXIMATE NET
GROUND
AMPACITY
CORE
O.D.
ARMOR
O.D.
THICKNESS
OVERALL
O.D.
WEIGHT
MIN.
BEND
RADIUS¹
COND.
@ 30°C
(AWG) INCHES mm INCHES mm mils mm INCHES mm LBS/1000 FT kg/1000 m INCHES
mm AMBIENT²

12 (7/W)
9675.01203318 (3.31
mm²)

3

45 1.14 3 x #18 0.40 10.2 0.60 15.3 50 1.27 0.70 17.8

249

370

7.0

178

30

10 (7/W)
9675.01003316 (5.26
mm²)

3

45 1.14 3 x #16 0.45 11.5 0.63 16.1 50 1.27 0.73 18.6

299

445

7.3

185

40

8 (7/W)
9675.00803314 (8.36
mm²)

3

45 1.14 3 x #14 0.50 12.7 0.76 19.2 50 1.27 0.86 21.9

417

620

8.6

218

55

6 (7/W)
9675.00603312 (13.3
mm²)

3

60 1.52 3 x #12 0.64 16.3 0.91 23.2 50 1.27 1.02 26.0

601

895

12.2

311

75

4 (7/W)
9675.00403312 (21.2
mm²)

3

60 1.52 3 x #12 0.74 18.7 0.98 24.8 50 1.27 1.08 27.4

763

1,135

12.9

329

95

2 (7/W)
9675.00203310 (33.6
mm²)

3

60 1.52 3 x #10 0.86 21.8 1.18 29.9 50 1.27 1.28 32.5

1,122

1,670

15.4

390

130

1 (19/W)
9675.00103310 (42.4
mm²)

3

80 2.03 3 x #10 1.01 25.7 1.36 34.6 50 1.27 1.46 37.1

1,404

2,090

17.5

445

145

1/0 (19/W)
9675.11003310 (53.5
mm²)

3

80 2.03 3 x #10 1.09 27.8 1.42 36.0 50 1.27 1.52 38.6

1,623

2,415

18.2

462

170

2/0 (19/W)
9675.21003310 (67.4
mm²)

3

80 2.03 3 x #10 1.18 30.0 1.56 39.6 50 1.27 1.66 42.2

2,043

3,040

20.0

506

195

(19/W)
9675.41003308 4/0
(107 mm²)

3

80 2.03

3 x #8

1.40 35.5 1.75 44.4 50 1.27 1.85 47.0

2,950

4,390

22.2

564

260

(37/W)
9675.25003308 250
(127 mm²)

3

90 2.29

3 x #8

1.49 37.8 1.90 48.2 50 1.27 2.01 51.1

3,380

5,030

24.1

612

290

(37/W)
9675.35003308 350
(177 mm²)

3

90 2.29

3 x #8

1.74 44.3 2.22 56.4 50 1.27 2.33 59.2

4,465

6,645

27.9

710

350

(37/W)
9675.50003306 500
(253 mm²)

3

90 2.29

3 x #6

2.00 50.9 2.48 63.0 50 1.27 2.59 65.8

6,152

9,155

31.0

789

430

Dimensions and weights are nominal; subject to industry tolerances.
¹ Minimum bend radius per Canadian Electrical Code, Part I, Section 12-712.
² Ampacity per Table #2, Canadian Electical Code.

Phone: 888-593-3355
www.generalcable.com

SPEC 9700

February, 2011

CCW Armored Power, 2.4 kV, Nonshielded, 3/C VFD
®

UL Type MC-HL or MV-90, EPR, 90°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Compact stranding per ASTM B496
Extruded Strand Shield (ESS):
•	Extruded thermoset semi-conductor
stress control layer over conductor per
ICEA S-96-659 and UL 1072
Insulation:
•	90 mils Ethylene Propylene Rubber
(EPR) insulation per ICEA S-96-659
and UL 1072
•	Insulation is printed 1-black, 2-red and
3-blue for phase identification
Grounding Conductors:
•	Three (3) split Class B stranded
bare annealed copper grounding
conductors
•	Sized in accordance with UL 1072 and
NEC Table 250.122
Cable Assembly:
•	Insulated and grounding conductors
are cabled together with nonhygroscopic fillers when required
•	Binder tape is applied over the cabled
core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1072 and UL 1569
•	CCW armor conductivity meets
the grounding requirements of NEC
Article 250
Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC), yellow
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Phone: 888-593-3355
www.generalcable.com

Applications:
•	Variable Frequency Drives:
3-conductor CCW armored cables
with three (3) symmetrical grounding
wires are the preferred wiring method
for use with AC motors controlled by
pulse-width modulated inverters in
VFD applications
•	CCW armored Medium-Voltage
power cables offer an economical,
rugged and reliable alternative to
labor-intensive cable in conduit wiring
methods
•	For use on feeders and branch circuits
in industrial power distribution systems
per NEC Articles 328 and 330
•	For use in Class I, II and III, Divisions
1 and 2; and Class I, Zones 1 and 2
hazardous locations per NEC Articles
501, 502, 503 and 505
•	Installed on metal racks, troughs, in
raceways, in cable trays or secured
to supports spaced not more than six
feet apart
•	Installed in both exposed and
concealed work, wet or dry locations,
directly buried or embedded in
concrete
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
and meets the grounding requirements
of UL 1072 and the NEC
•	Factory assembled and tested cable
for use as an alternative to cable in
conduit wiring systems

Features: (cont’d)
•	General Cable’s EPR insulation system
has outstanding corona resistance and
high dielectric strength, and it provides
electrical stability under stress
•	Cable meets cold impact at -40°C
•	90˚C continuous operating
temperature, wet or dry
•	140˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	ICEA S-96-659/WC71 Standard for
Nonshielded Cables Rated 2001 –
5000 Volts
•	UL 1072 Medium-Voltage Power
Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309 Marine Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1072
•	IEC 60332-3 Category A
Compliances:
•	UL Type MV-90, UL File # E90501
•	UL Type MC-HL, SUN RES, CT
USE, DIR BUR, -40°C, FT4, UL File #
E90496
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9700

February, 2011

CCW Armored Power, 2.4 kV, Nonshielded, 3/C VFD
®

UL Type MC-HL or MV-90, EPR, 90°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC
COND.
SIZE
CATALOG
NUMBER

AWG
(kcmil)

INSULATION
THICKNESS

NO.
OF
COND. mils

NOMINAL O.D.
OVER
BARE
INSULATION GROUND

mm INCHES mm

AWG

NOMINAL
CORE O.D.

NOMINAL
ARMOR O.D.

INCHES mm INCHES mm

JACKET
THICKNESS
mils

NOMINAL
OVERALL O.D.

mm INCHES mm

APPROXIMATE NET
WEIGHT
LBS/
1000 FT

kg/
1000 m

AMPACITY
DIRECT
IN AIR¹ BURIAL²

3/C WITH GROUND MC-HL OR MV-90, 90 MILS EPR, 2.4 kV, YELLOW JACKET
9700.00803312

8 (7/W)
(8.36 mm²)

3

90

2.3 0.36 9.1 3 x #12 0.77 19.6 0.97 24.6 50 1.27 1.08 27.4

570

848

59

85

9700.00603310

6 (7/W)
(13.3 mm²)

3

90

2.3 0.38 9.6 3 x #10 0.85 21.6 1.06 26.9 50 1.27 1.17 29.7

745

1,109

79

105

9700.00403310

4 (7/W)
(21.2 mm²)

3

90

2.3 0.43 10.8 3 x #10 0.97 24.6 1.19 30.2 50 1.27 1.30 33.0

965

1,436

105

135

9700.00203310

2 (7/W)
(33.6 mm²)

3

90

2.3 0.48 12.1 3 x #10 1.10 27.9 1.34 34.0 50 1.27 1.45 36.8

1,275

1,897

140

180

9700.00103308

1 (19/W)
(42.4 mm²)

3

90

2.3 0.52 13.1 3 x #8 1.16 29.5 1.42 36.1 50 1.27 1.53 38.9

1,525

2,269

160

200

9700.11003308

1/0 (19/W)
(53.5 mm²)

3

90

2.3 0.55 13.9 3 x #8 1.23 31.2 1.51 38.4 60 1.52 1.65 41.9

1,840

2,738

185

230

9700.21003308

2/0 (19/W)
(67.4 mm²)

3

90

2.3 0.59 14.9 3 x #8 1.33 33.8 1.60 40.6 60 1.52 1.73 43.9

2,165

3,222

215

260

9700.41003307

4/0 (19/W)
(107 mm²)

3

90

2.3 0.69 17.4 3 x #7 1.53 38.9 1.83 46.5 60 1.52 1.96 49.8

3,080

4,584

285

335

9700.25003307

250 (37/W)
(127 mm²)

3

90

2.3 0.74 18.7 3 x #7 1.64 41.7 1.96 49.8 60 1.52 2.09 53.1

3,475

5,171

320

365

9700.35003306

350 (37/W)
(177 mm²)

3

90

2.3 0.83 21.0 3 x #6 1.86 47.2 2.19 55.6 60 1.52 2.32 58.9

4,710

7,009

395

440

9700.50003305

500 (37/W)
(253 mm²)

3

90

2.3 0.95 24.0 3 x #5 2.10 53.3 2.45 62.2 75 1.91 2.61 66.3

6,410

9,539

485

530

9700.75003304

750 (61/W)
(380 mm²)

3

90

2.3 1.12 28.3 3 x #4 2.51 63.8 2.93 74.4 75 1.91 3.10 78.7

9,225 13,728

615

650

9700.10003304

1000 (61/W)
(507 mm²)

3

90

2.3 1.27 32.2 3 x #4 2.90 73.7 3.41 86.6 80 2.03 3.59 91.2 12,080 17,977

705

730

Dimensions and weights are nominal, subject to industry tolerances.
¹ In-air ampacities are per NEC Table 310.60(C)(71) for three insulated copper conductors rated 90°C, cabled with an overall covering and isolated in air at 40°C ambient temperature.
² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors rated 90°C, cabled within an overall covering and directly buried in earth at 20°C
ambient earth temperature.

Phone: 888-593-3355
www.generalcable.com

SPEC 9800

May, 2012

CCW Armored Power, 5 kV 133%/8 kV 100%, Shielded, 3/C VFD
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Compact stranding per ASTM B496
Extruded Strand Shield (ESS):
•	Extruded thermoset semi-conductor
stress control layer over the conductor
per ICEA S-93-639 and UL 1072
Insulation:
•	115 mils Ethylene Propylene Rubber
(EPR) insulation per ICEA S-93-639
and UL 1072
Extruded Insulation Shield (EIS):
•	Thermoset semi-conducting polymeric
layer, free stripping from the insulation
per ICEA S-93-639 and UL 1072
Shield:
•	5 mil annealed bare copper tape with
25% overlap
Phase Identification:
•	Color-coded polymeric identification
tape laid under the shield — black, red
and blue
Grounding Conductors:
•	Three (3) split Class B stranded
bare annealed copper grounding
conductors
•	Sized in accordance with UL 1072 and
NEC Article 250
Cable Assembly:
•	Insulated and grounding conductors
are cabled together with nonhygroscopic fillers when required
•	Binder tape is applied over the cabled
core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1072 and UL 1569
•	CCW armor conductivity meets
the grounding requirements of NEC
Article 250

Phone: 888-593-3355
www.generalcable.com

Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC), yellow
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	Variable Frequency Drives:
3-conductor CCW armored cables
with three (3) symmetrical grounding
wires are the preferred wiring method
for use with AC motors controlled by
pulse-width modulated inverters in
VFD applications
•	CCW armored Medium-Voltage
power cables offer an economical,
rugged and reliable alternative to
labor-intensive cable in conduit wiring
methods
•	For use on feeders and branch circuits
in industrial power distribution systems
per NEC Articles 328 and 330
•	For use in Class I, II and III, Divisions
1 and 2; and Class I, Zones 1 and 2
hazardous locations per NEC Articles
501, 502, 503 and 505
•	Installed on metal racks, troughs, in
raceways, in cable trays or secured
to supports spaced not more than six
feet apart
•	Installed in both exposed and
concealed work, wet or dry locations,
directly buried or embedded in
concrete
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
and meets the grounding requirements
of UL 1072 and the NEC

Features: (cont’d)
•	Triple Extrusion: The strand shield,
EPR insulation and insulation shield
are all extruded in one operation
•	General Cable’s EPR insulation system
has outstanding corona resistance and
high dielectric strength, and it provides
electrical stability under stress
•	Cable meets cold impact at -40°C
•	105˚C continuous operating
temperature, wet or dry
•	140˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	ICEA S-93-639/WC-74, 5-46 kV
Shielded Power Cable
•	AEIC CS8 Specification for Shielded
Power Cable, 5-46 kV
•	UL 1072 Medium-Voltage Power
Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309 Marine Shipboard Cable
•	CSA C68.3
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1072
•	IEC 60332-3 Category A
Compliances:
•	UL Type MV-105, UL File # E90501
•	UL Type MC-HL, SUN RES, CT
USE, DIR BUR, -40°C, FT4, UL File #
E90496
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9800

May, 2012

CCW Armored Power, 5 kV 133%/8 kV 100%, Shielded, 3/C VFD
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC
COND.
SIZE
CATALOG
NUMBER

INSULATION
THICKNESS

NO. OF
AWG (kcmil) COND. mils

NOMINAL O.D.
OVER
BARE
INSULATION GROUND

mm INCHES mm

AWG

NOMINAL
CORE O.D.

NOMINAL
ARMOR O.D.

INCHES mm INCHES mm

JACKET
THICKNESS
mils

NOMINAL
OVERALL O.D.

mm INCHES mm

APPROXIMATE NET
WEIGHT
LBS/
1000 FT

kg/
1000 m

5 kV³
AMPACITY
DIRECT
IN AIR¹ BURIAL²

3/C WITH GROUND MC-HL OR MV-105, 115 MILS EPR, 5 kV 133% AND 8 kV 100% INSULATION LEVEL
9800.00603310

6 (7/W)
(13.3 mm²)

3

115 2.9

0.43 10.9 3 x #10 1.15 29.2 1.37 34.8

50

1.27 1.48

37.6

1,121

1,668

88

115

9800.00403310

4 (7/W)
(21.2 mm²)

3

115 2.9

0.48 12.2 3 x #10 1.24 31.5 1.51 38.4

60

1.52 1.65

41.9

1,418

2,110

115

150

9800.00203310

2 (7/W)
(33.6 mm²)

3

115 2.9

0.53 13.5 3 x #10 1.37 34.8 1.64 41.7

60

1.52 1.78

45.2

1,731

2,576

154

190

9800.00103308

1 (19/W)
(42.4 mm²)

3

115 2.9

0.57 14.5 3 x #8 1.47 37.3 1.69 42.9

60

1.52 1.82

46.2

1,978

2,944

180

215

9800.11003308

1/0 (19/W)
(53.5 mm²)

3

115 2.9

0.60 15.2 3 x #8 1.56 39.6 1.78 45.2

60

1.52 1.91

48.5

2,259

3,362

205

245

9800.21003308

2/0 (19/W)
(67.4 mm²)

3

115 2.9

0.64 16.3 3 x #8 1.61 40.9 1.92 48.8

60

1.52 2.05

52.1

2,626

3,908

240

280

9800.41003307

4/0 (19/W)
(107 mm²)

3

115 2.9

0.74 18.8 3 x #7 1.82 46.2 2.15 54.6

60

1.52 2.28

57.9

3,650

5,432

320

360

9800.25003306

250 (37/W)
(127 mm²)

3

115 2.9

0.80 20.3 3 x #6 2.01 51.1 2.23 56.6

60

1.52 2.36

59.9

4,060

6,042

355

395

9800.35003306

350 (37/W)
(177 mm²)

3

115 2.9

0.89 22.6 3 x #6 2.10 53.3 2.45 62.2

75

1.91 2.61

66.3

5,045

7,508

440

475

9800.50003305

500 (37/W)
(253 mm²)

3

115 2.9

1.01 25.7 3 x #5 2.39 60.7 2.75 69.9

75

1.91 2.92

74.2

7,137

10,621

545

570

9800.75003304

750 (61/W)
(380 mm²)

3

115 2.9

1.19 30.2 3 x #4 3.07 78.0 3.32 84.3

85

2.16 3.50

88.9 10,268

15,280

685

700

9800.10003304

1000 (61/W)
(507 mm²)

3

115 2.9

1.34 34.0 3 x #4 3.43 87.1 3.76 95.5

85

2.16 3.94 100.1 13,051

19,422

790

785

Dimensions and weights are nominal; subject to industry tolerances.
¹ In-air ampacities are per NEC Table 310.60(C)(71) for three insulated copper conductors rated 105°C, cabled with an overall covering and isolated in air at 40°C ambient temperature.
² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors rated 105°C, cabled within an overall covering and directly buried in earth at 20°C
ambient earth temperature.
³ For 8 kV ampacities, refer to NEC Tables 310.60(C)(71) and 310.60(C)(83) for cables listed 5001-35,000 volts.

Phone: 888-593-3355
www.generalcable.com

SPEC 9815

May, 2012

CCW Armored Power, 8 kV 133%, Shielded, 3/C VFD
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Compact stranding per ASTM B496
Extruded Strand Shield (ESS):
•	Extruded thermoset semi-conductor
stress control layer over the conductor
per ICEA S-93-639 and UL 1072
Insulation:
•	140 mils Ethylene Propylene Rubber
(EPR) insulation per ICEA S-93-639
and UL 1072
Extruded Insulation Shield (EIS):
•	Thermoset semi-conducting polymeric
layer, free stripping from the insulation
per ICEA S-93-639 and UL 1072
Shield:
•	5 mil annealed bare copper tape with
25% overlap
Phase Identification:
•	Color-coded polymeric identification
tape laid under the shield - black, red
and blue
Grounding Conductors:
•	Three (3) split Class B stranded
bare annealed copper grounding
conductors
•	Sized in accordance with UL 1072 and
NEC Article 250
Cable Assembly:
•	Insulated and grounding conductors
are cabled together with nonhygroscopic fillers when required
•	Binder tape is applied over the cabled
core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1072 and UL 1569
•	CCW armor conductivity meets the
grounding requirements of the NEC

Phone: 888-593-3355
www.generalcable.com

Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC), yellow
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	Variable Frequency Drives:
3-conductor CCW armored cables
with three (3) symmetrical grounding
wires are the preferred wiring method
for use with AC motors controlled by
pulse-width modulated inverters in
VFD applications
•	CCW armored Medium-Voltage
power cables offer an economical,
rugged and reliable alternative to
labor-intensive cable in conduit wiring
methods
•	For use on feeders and branch circuits
in industrial power distribution systems
per NEC Articles 328 and 330
•	For use in Class I, II and III, Divisions
1 and 2; and Class I, Zones 1 and 2
hazardous locations per NEC Articles
501, 502, 503 and 505
•	Installed on metal racks, troughs, in
raceways, in cable trays or secured
to supports spaced not more than six
feet apart
•	Installed in both exposed and
concealed work, wet or dry locations,
directly buried or embedded in
concrete
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
and meets the grounding requirements
of UL 1072 and the NEC

Features: (cont’d)
•	Triple Extrusion: The strand shield,
EPR insulation and insulation shield
are all extruded in one operation
•	General Cable’s EPR insulation system
has outstanding corona resistance and
high dielectric strength, and it provides
electrical stability under stress
•	Cable meets cold impact at -40°C
•	105˚C continuous operating
temperature, wet or dry
•	140˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	ICEA S-93-639/WC74, 5-46 kV
Shielded Power Cable
•	AEIC CS8 Specification for Shielded
Power Cable, 5-46 kV
•	UL 1072 Medium-Voltage Power
Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309 Marine Shipboard Cable
•	CSA C68.3
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1072
•	IEC 60332-3 Category A
Compliances:
•	UL Type MV-105, UL File # E90501
•	UL Type MC-HL, SUN RES, CT
USE, DIR BUR, -40°C, FT4, UL File #
E90496
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9815

May, 2012

CCW Armored Power, 8 kV 133%, Shielded, 3/C VFD
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC
COND.
SIZE
CATALOG
NUMBER

INSULATION
THICKNESS

NO. OF
AWG (kcmil) COND. mils

NOMINAL O.D.
OVER
BARE
INSULATION GROUND

mm INCHES mm

AWG

NOMINAL
CORE O.D.

NOMINAL
ARMOR O.D.

INCHES mm INCHES mm

JACKET
THICKNESS

NOMINAL
OVERALL O.D.

APPROXIMATE NET
WEIGHT

mils

INCHES

LBS/
1000 FT

mm

mm

kg/
1000 m

AMPACITY
DIRECT
IN AIR¹ BURIAL²

3/C WITH GROUND MC-HL OR MV-105, 140 MILS EPR, 8 kV 133% INSULATION LEVEL
9815.00603310

6 (7/W)
(13.3 mm²)

3

140 3.6

0.48 12.2 3 x #10 1.20 30.5 1.60

40.6

60

1.52

1.73

43.9

1,350

2,009

105

120

9815.00403310

4 (7/W)
(21.2 mm²)

3

140 3.6

0.53 13.5 3 x #10 1.29 32.8 1.70

43.2

60

1.52

1.83

46.5

1,600

2,381

135

155

9815.00203310

2 (7/W)
(33.6 mm²)

3

140 3.6

0.58 14.7 3 x #10 1.42 36.1 1.85

47.0

60

1.52

1.98

50.3

2,000

2,976

185

200

9815.00103308

1 (19/W)
(42.4 mm²)

3

140 3.6

0.62 15.7 3 x #8 1.52 38.6 1.93

49.0

60

1.52

2.06

52.3

2,275

3,386

210

225

9815.11003308

1/0 (19/W)
(53.5 mm²)

3

140 3.6

0.65 16.5 3 x #8 1.61 40.9 2.03

51.6

60

1.52

2.16

54.9

2,600

3,869

240

255

9815.21003308

2/0 (19/W)
(67.4 mm²)

3

140 3.6

0.69 17.5 3 x #8 1.66 42.2 2.14

54.4

60

1.52

2.27

57.7

2,950

4,390

275

290

9815.41003307

4/0 (19/W)
(107 mm²)

3

140 3.6

0.79 20.1 3 x #7 1.87 47.5 2.40

61.0

75

1.91

2.56

65.0

4,025

5,990

360

375

9815.25003306

250 (37/W)
(127 mm²)

3

140 3.6

0.85 21.6 3 x #6 2.06 52.3 2.59

65.8

75

1.91

2.75

69.9

4,600

6,846

400

410

9815.35003306

350 (37/W)
(177 mm²)

3

140 3.6

0.94 23.9 3 x #6 2.15 54.6 2.85

72.4

75

1.91

3.01

76.5

5,800

8,631

490

495

9815.50003305

500 (37/W)
(253 mm²)

3

140 3.6

1.06 26.9 3 x #5 2.44 62.0 3.19

81.0

85

2.16

3.37

85.6

7,800

11,608

600

590

9815.75003304

750 (61/W)
(380 mm²)

3

140 3.6

1.26 32.0 3 x #4 3.19 81.0 3.68

93.5

85

2.16

3.86

98.0 10,750

15,998

745

720

9815.10003304

1000 (61/W)
(507 mm²)

3

140 3.6

1.42 36.1 3 x #4 3.48 88.4 3.98 101.1

85

2.16

4.16 105.7 13,550

20,165

860

810

Dimensions and weights are nominal; subject to industry tolerances.
¹ In-air ampacities are per NEC Table 310.60(C)(71) for three insulated copper conductors rated 105°C, cabled with an overall covering and isolated in air at 40°C ambient temperature.
² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors rated 105°C, cabled within an overall covering and directly buried in earth at 20°C
ambient earth temperature.

Phone: 888-593-3355
www.generalcable.com

SPEC 9825

May, 2012

CCW Armored Power, 15 kV 100%, Shielded, 3/C
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Compact stranding per ASTM B496
Extruded Strand Shield (ESS):
•	Extruded thermoset semi-conductor
stress control layer over the conductor
per ICEA S-93-639 and UL 1072
Insulation:
•	175 mils Ethylene Propylene Rubber
(EPR) insulation per ICEA S-93-639
and UL 1072
Extruded Insulation Shield (EIS):
•	Thermoset semi-conducting polymeric
layer, free stripping from the insulation
per ICEA S-93-639 and UL 1072
Shield:
•	5 mil annealed bare copper tape with
25% overlap
Phase Identification:
•	Color-coded polymeric identification
tape laid under the shield - black, red
and blue
Grounding Conductor:
•	Class B stranded bare annealed
copper grounding conductor
•	Sized in accordance with UL 1072 and
NEC Article 250
Cable Assembly:
•	Insulated and grounding conductors
are cabled together with nonhygroscopic fillers when required
•	Binder tape is applied over the cabled
core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1072 and UL 1569
•	CCW armor conductivity meets the
grounding requirements of the NEC

Phone: 888-593-3355
www.generalcable.com

Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC), red
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored Medium-Voltage
power cables offer an economical,
rugged and reliable alternative to
labor-intensive cable in conduit wiring
methods
•	For use on feeders and branch circuits
in industrial power distribution systems
per NEC Articles 328 and 330
•	For use in Class I, II and III, Divisions
1 and 2; and Class I, Zones 1 and 2
hazardous locations per NEC Articles
501, 502, 503 and 505
•	Installed on metal racks, troughs, in
raceways, in cable trays or secured
to supports spaced not more than six
feet apart
•	Installed in both exposed and
concealed work, wet or dry locations,
directly buried or embedded in
concrete
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
and meets the grounding requirements
of UL 1072 and the NEC
•	Triple Extrusion: The strand shield,
EPR insulation and insulation shield
are all extruded in one operation

Features: (cont’d)
•	General Cable’s EPR insulation system
has outstanding corona resistance and
high dielectric strength, and it provides
electrical stability under stress
•	Cable meets cold impact at -40°C
•	105˚C continuous operating
temperature, wet or dry
•	140˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	ICEA S-93-639/WC-74, 5-46 kV
Shielded Power Cable
•	AEIC CS8 Specification for Shielded
Power Cable, 5-46 kV
•	UL 1072 Medium-Voltage Power
Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309 Marine Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1072
•	IEC 60332-3 Category A
Compliances:
•	UL Type MV-105, UL File # E90501
•	UL Type MC-HL, SUN RES, CT
USE, DIR BUR, -40°C, FT4, UL File #
E90496
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9825

May, 2012

CCW Armored Power, 15 kV 100%, Shielded, 3/C
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC
COND.
SIZE
CATALOG
NUMBER

INSULATION
THICKNESS

NO. OF
AWG (kcmil) COND. mils

NOMINAL O.D.
OVER
BARE
INSULATION GROUND

mm INCHES mm

AWG

NOMINAL
CORE O.D.

NOMINAL
ARMOR O.D.

INCHES mm INCHES mm

JACKET
THICKNESS

NOMINAL
OVERALL O.D.

APPROXIMATE NET
WEIGHT

mils

INCHES

LBS/
1000 FT

mm

mm

kg/
1000 m

AMPACITY
DIRECT
IN AIR¹ BURIAL²

3/C WITH GROUND MC-HL OR MV-105, 175 MILS EPR, 15 kV 100% INSULATION LEVEL
9825.00203106

2 (7/W)
(33.6 mm²)

3

175 4.4 0.65 16.5

6

1.61 40.9 1.96 49.8

60

1.52 2.05 52.1

2,077

3,091

185

200

9825.00103104

1 (19/W)
(42.4 mm²)

3

175 4.4 0.69 17.5

4

1.68 42.7 2.01 51.1

60

1.52 2.15 54.6

2,469

3,674

210

225

9825.11003104

1/0 (19/W)
(53.5 mm²)

3

175 4.4 0.72 18.3

4

1.78 45.2 2.10 53.3

60

1.52 2.24 56.9

2,760

4,107

240

255

9825.21003104

2/0 (19/W)
(67.4 mm²)

3

175 4.4 0.76 19.3

4

1.88 47.8 2.19 55.6

60

1.52 2.36 59.9

3,130

4,658

275

290

9825.41003103

4/0 (19/W)
(107 mm²)

3

175 4.4 0.86 21.8

3

2.09 53.1 2.45 62.2

75

1.91 2.61 66.3

4,290

6,384

360

375

9825.25003102

250 (37/W)
(127 mm²)

3

175 4.4 0.92 23.4

2

2.19 55.6 2.58 65.5

75

1.91 2.74 69.6

4,775

7,106

400

410

9825.35003102

350 (37/W)
(177 mm²)

3

175 4.4 1.01 25.7

2

2.45 62.2 2.85 72.4

75

1.91 3.01 76.5

6,132

9,125

490

495

9825.50003101

500 (37/W)
(253 mm²)

3

175 4.4 1.13 28.7

1

2.71 68.8 3.16 80.3

85

2.16 3.34 84.8

8,052 11,983

600

590

9825.750031110

750 (61/W)
(380 mm²)

3

175 4.4 1.31 33.3

1/0

3.12 79.2 3.67 93.2

85

2.16 3.85 97.8 11,098 16,516

745

720

Dimensions and weights are nominal; subject to industry tolerances.
¹ Ampacities in air are per NEC Table 310.60(C)(71) for an insulated three-conductor copper cable isolated in air with 105°C rated conductors at a 40°C ambient temperature.	
² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors cabled within an overall covering, directly buried in earth with 105°C rated conductors
at 20°C ambient earth temperature.

Phone: 888-593-3355
www.generalcable.com

SPEC 9835

May, 2012

CCW Armored Power, 15 kV 133%, Shielded, 3/C
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Compact stranding per ASTM B496
Extruded Strand Shield (ESS):
•	Extruded thermoset semi-conductor
stress control layer over the conductor
per ICEA S-93-639 and UL 1072
Insulation:
•	220 mils Ethylene Propylene Rubber
(EPR) insulation per ICEA S-93-639
and UL 1072
Extruded Insulation Shield (EIS):
•	Thermoset semi-conducting polymeric
layer, free stripping from the insulation
per ICEA S-93-639 and UL 1072
Shield:
•	5 mil annealed bare copper tape with
25% overlap
Phase Identification:
•	Color-coded polymeric identification
tape laid under the shield - black, red
and blue
Grounding Conductor:
•	Class B stranded bare annealed
copper grounding conductor
•	Sized in accordance with UL 1072 and
NEC Article 250
Cable Assembly:
•	Insulated and grounding conductors
are cabled together with nonhygroscopic fillers when required
•	Binder tape is applied over the cabled
core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1072 and UL 1569
•	CCW armor conductivity meets the
grounding requirements of the NEC

Phone: 888-593-3355
www.generalcable.com

Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC), red
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored Medium-Voltage
power cables offer an economical,
rugged and reliable alternative to
labor-intensive cable in conduit wiring
methods
•	For use on feeders and branch circuits
in industrial power distribution systems
per NEC Articles 328 and 330
•	For use in Class I, II and III, Divisions
1 and 2; and Class I, Zones 1 and 2
hazardous locations per NEC Articles
501, 502, 503 and 505
•	Installed on metal racks, troughs, in
raceways, in cable trays or secured
to supports spaced not more than six
feet apart
•	Installed in both exposed and
concealed work, wet or dry locations,
directly buried or embedded in
concrete
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
and meets the grounding requirements
of UL 1072 and the NEC
•	Triple Extrusion: The strand shield,
EPR insulation and insulation shield
are all extruded in one operation

Features: (cont’d)
•	General Cable’s EPR insulation system
has outstanding corona resistance and
high dielectric strength, and it provides
electrical stability under stress
•	Cable meets cold impact at -40°C
•	105˚C continuous operating
temperature, wet or dry
•	140˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	ICEA S-93-639/WC-74, 5-46 kV
Shielded Power Cable
•	AEIC CS8 Specification for Shielded
Power Cable, 5-46 kV
•	UL 1072 Medium-Voltage Power
Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309 Marine Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1072
•	IEC 60332-3 Category A
Compliances:
•	UL Type MV-105, UL File # E90501
•	UL Type MC-HL, SUN RES, CT
USE, DIR BUR, -40°C, FT4, UL File #
E90496
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9835

May, 2012

CCW Armored Power, 15 kV 133%, Shielded, 3/C
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC
COND.
SIZE
CATALOG
NUMBER

INSULATION
THICKNESS

NO. OF
AWG (kcmil) COND. mils

NOMINAL O.D.
OVER
BARE
INSULATION GROUND

mm INCHES mm

NOMINAL
CORE O.D.

NOMINAL
ARMOR O.D.

AWG INCHES mm INCHES mm

JACKET
THICKNESS
mils

mm

NOMINAL
OVERALL O.D.
INCHES

mm

APPROXIMATE NET
WEIGHT
LBS/
1000 FT

kg/
1000 m

AMPACITY
DIRECT
IN AIR¹ BURIAL²

3/C WITH GROUND MC-HL OR MV-105, 220 MILS EPR, 15 kV 133% INSULATION LEVEL
9835.00203106

2 (7/W)
(33.6 mm²)

3

220 5.6 0.76 19.3

6

1.82 46.2 2.15 54.6

60

1.52 2.28

57.9

2,473

3,680 185

200

9835.00103104

1 (19/W)
(42.4 mm²)

3

220 5.6 0.79 20.1

4

1.88 47.8 2.23 56.6

60

1.52 2.36

59.9

2,811

4,183 210

225

9835.11003104

1/0 (19/W)
(53.5 mm²)

3

220 5.6 0.83 21.1

4

1.96 49.8 2.32 58.9

75

1.91 2.48

63.0

3,190

4,747 240

255

9835.21003104

2/0 (19/W)
(67.4 mm²)

3

220 5.6 0.87 22.1

4

2.06 52.3 2.40 61.0

75

1.91 2.56

65.0

3,630

5,402 275

290

9835.41003103

4/0 (19/W)
(107 mm²)

3

220 5.6 0.97 24.6

3

2.26 57.4 2.62 66.5

75

1.91 2.79

70.9

4,435

6,600 360

345

9835.25003102

250 (37/W)
(127 mm²)

3

220 5.6 1.03 26.2

2

2.36 59.9 2.75 69.9

75

1.91 2.92

74.2

5,086

7,569 400

410

9835.35003102

350 (37/W)
(177 mm²)

3

220 5.6 1.12 28.4

2

2.61 66.3 3.03 77.0

85

2.16 3.21

81.5

6,445

9,591 490

495

9835.50003101

500 (37/W)
(253 mm²)

3

220 5.6 1.24 31.5

1

2.86 72.6 3.32 84.3

85

2.16 3.50

88.9

8,376 12,465 600

590

9835.750031110

750 (61/W)
(380 mm²)

3

220 5.6 1.41 35.8

1/0

3.25 82.6 3.80 96.5

85

2.16 3.98 101.1 11,431 17,011 745

720

Dimensions and weights are nominal; subject to industry tolerances.
¹ Ampacities in air are per NEC Table 310.60(C)(71) for an insulated three-conductor copper cable isolated in air with 105°C rated conductors at a 40°C ambient temperature.	
² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors cabled within an overall covering, directly buried in earth with 105°C rated conductors
at 20°C ambient earth temperature.

Phone: 888-593-3355
www.generalcable.com

SPEC 9845

May, 2012

CCW Armored Power, 25 kV 100%, Shielded, 3/C
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Compact stranding per ASTM B496
Extruded Strand Shield (ESS):
•	Extruded thermoset semi-conductor
stress control layer over the conductor
per ICEA S-93-639 and UL 1072
Insulation:
•	260 mils Ethylene Propylene Rubber
(EPR) insulation per ICEA S-93-639
and UL 1072
Extruded Insulation Shield (EIS):
•	Thermoset semi-conducting polymeric
layer, free stripping from the insulation
per ICEA S-93-639 and UL 1072
Shield:
•	5 mil annealed bare copper tape with
25% overlap
Phase Identification:
•	Color-coded polymeric identification
tape laid under the shield - black, red
and blue
Grounding Conductor:
•	Class B stranded bare annealed
copper grounding conductor
•	Sized in accordance with UL 1072 and
NEC Article 250
Cable Assembly:
•	Insulated and grounding conductors
are cabled together with nonhygroscopic fillers when required
•	Binder tape is applied over the cabled
core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1072 and UL 1569
•	CCW armor conductivity meets the
grounding requirements of the NEC

Phone: 888-593-3355
www.generalcable.com

Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC) per UL 1072, orange
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored Medium-Voltage
power cables offer an economical,
rugged and reliable alternative to
labor-intensive cable in conduit wiring
methods
•	For use on feeders and branch circuits
in industrial power distribution systems
per NEC Articles 328 and 330
•	For use in Class I, II and III, Divisions
1 and 2; and Class I, Zones 1 and 2
hazardous locations per NEC Articles
501, 502, 503 and 505
•	Installed on metal racks, troughs, in
raceways, in cable trays or secured
to supports spaced not more than six
feet apart
•	Installed in both exposed and
concealed work, wet or dry locations,
directly buried or embedded in
concrete
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
and meets the grounding requirements
of UL 1072 and the NEC
•	Triple Extrusion: The strand shield,
EPR insulation and insulation shield
are all extruded in one operation

Features: (cont’d)
•	General Cable’s EPR insulation system
has outstanding corona resistance and
high dielectric strength, and it provides
electrical stability under stress
•	Cable meets cold impact at -40°C
•	105˚C continuous operating
temperature, wet or dry
•	140˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	ICEA S-93-639/WC-74, 5-46 kV
Shielded Power Cable
•	AEIC CS8 Specification for Shielded
Power Cable, 5-46 kV
•	UL 1072 Medium-Voltage Power
Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309 Marine Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1072
•	IEC 60332-3 Category A
Compliances:
•	UL Type MV-105, UL File # E90501
•	UL Type MC-HL, SUN RES, CT
USE, DIR BUR, -40°C, FT4, UL File #
E90496
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9845

May, 2012

CCW Armored Power, 25 kV 100%, Shielded, 3/C
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC
COND.
SIZE
CATALOG
NUMBER

INSULATION
THICKNESS

NO. OF
AWG (kcmil) COND. mils

NOMINAL O.D.
OVER
BARE
INSULATION GROUND

mm INCHES mm

AWG

NOMINAL
CORE O.D.

NOMINAL
ARMOR O.D.

INCHES mm INCHES mm

JACKET
THICKNESS

NOMINAL
OVERALL O.D.

APPROXIMATE NET
WEIGHT

mils

INCHES

LBS/
1000 FT

mm

mm

kg/
1000 m

AMPACITY
DIRECT
IN AIR¹ BURIAL²

3/C WITH GROUND MC-HL OR MV-105, 260 MILS EPR, 25 kV 100% INSULATION LEVEL
9845.00103104

1 (19/W)
(42.4 mm²)

3

260 6.6 0.87 22.1

4

2.07 52.6 2.45 62.2 75 1.91 2.61 66.3 3,189

4,746

210

225

9845.11003104

1/0 (19/W)
(53.5 mm²)

3

260 6.6 0.90 22.9

4

2.15 54.6 2.53 64.3 75 1.91 2.69 68.3 3,536

5,262

240

255

9845.21003104

2/0 (19/W)
(67.4 mm²)

3

260 6.6 0.94 23.9

4

2.24 56.9 2.62 66.5 75 1.91 2.79 70.9 3,939

5,862

275

290

9845.41003103

4/0 (19/W)
(107 mm²)

3

260 6.6 1.04 26.4

3

2.51 63.8 2.93 74.4 75 1.91 3.10 78.7 5,122

7,622

360

345

9845.25003102

250 (37/W)
(127 mm²)

3

260 6.6 1.10 27.9

2

2.61 66.3 3.07 78.0 85 2.16 3.25 82.6 5,819

8,660

400

410

9845.35003102

350 (37/W)
(177 mm²)

3

260 6.6 1.19 30.2

2

2.82 71.6 3.32 84.3 85 2.16 3.50 88.9 7,115

10,588

490

495

9845.50003101

500 (37/W)
(253 mm²)

3

260 6.6 1.31 33.3

1

3.08 78.2 3.62 91.9 85 2.16 3.81 96.8 9,125

13,579

600

590

Dimensions and weights are nominal; subject to industry tolerances.
¹ In-air ampacities are per NEC Table 310.60(C)(71) for three insulated copper conductors rated 105°C, cabled with an overall covering and isolated in air at 40°C ambient temperature.
² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors rated 105°C, cabled within an overall covering and directly buried in earth at 20°C
ambient earth temperature.

Phone: 888-593-3355
www.generalcable.com

SPEC 9855

February, 2011

CCW Armored Power, 25 kV 133%/35 kV 100%, Shielded, 3/C
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Compact stranding per ASTM B496
Extruded Strand Shield (ESS):
•	Extruded thermoset semi-conductor
stress control layer over the conductor
per ICEA S-93-639 and UL 1072
Insulation:
•	345 mils Ethylene Propylene Rubber
(EPR) insulation per ICEA S-93-639
and UL 1072
Extruded Insulation Shield (EIS):
•	Thermoset semi-conducting polymeric
layer, free stripping from the insulation
per ICEA S-93-639 and UL 1072
Shield:
•	5 mil annealed bare copper tape with
25% overlap
Phase Identification:
•	Color-coded polymeric identification
tape laid under the shield - black, red
and blue
Grounding Conductor:
•	Class B stranded bare annealed
copper grounding conductor
•	Sized in accordance with UL 1072 and
NEC Article 250
Cable Assembly:
•	Insulated and grounding conductors
are cabled together with nonhygroscopic fillers when required
•	Binder tape is applied over the cabled
core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1072 and UL 1569
•	CCW armor conductivity meets the
grounding requirements of the NEC

Phone: 888-593-3355
www.generalcable.com

Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC) per UL 1072, orange
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored Medium-Voltage
power cables offer an economical,
rugged and reliable alternative to
labor-intensive cable in conduit wiring
methods
•	For use on feeders and branch circuits
in industrial power distribution systems
per NEC Articles 328 and 330
•	For use in Class I, II and III, Divisions
1 and 2; and Class I, Zones 1 and 2
hazardous locations per NEC Articles
501, 502, 503 and 505
•	Installed on metal racks, troughs, in
raceways, in cable trays or secured
to supports spaced not more than six
feet apart
•	Installed in both exposed and
concealed work, wet or dry locations,
directly buried or embedded in
concrete
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
and meets the grounding requirements
of UL 1072 and the NEC
•	Triple Extrusion: The strand shield,
EPR insulation and insulation shield
are all extruded in one operation

Features: (cont’d)
•	General Cable’s EPR insulation system
has outstanding corona resistance and
high dielectric strength, and it provides
electrical stability under stress
•	Cable meets cold impact at -40°C
•	105˚C continuous operating
temperature, wet or dry
•	140˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	ICEA S-93-639/WC74, 5-46 kV
Shielded Power Cable
•	AEIC CS8 Specification for Shielded
Power Cable, 5-46 kV
•	UL 1072 Medium-Voltage Power
Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309 Marine Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1072
•	IEC 60332-3 Category A
Compliances:
•	UL Type MV-105, UL File # E90501
•	UL Type MC-HL, SUN RES, CT
USE, DIR BUR, -40°C, FT4, UL File #
E90496
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9855

February, 2011

CCW Armored Power, 25 kV 133%/35 kV 100%, Shielded, 3/C
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC
COND.
SIZE
AWG
(kcmil)

CATALOG
NUMBER

INSULATION
THICKNESS
NO. OF
COND. mils

NOMINAL O.D.
OVER
BARE
INSULATION GROUND

mm INCHES mm

NOMINAL
CORE O.D.

NOMINAL
ARMOR O.D.

AWG INCHES mm INCHES

mm

JACKET
THICKNESS
mils

mm

NOMINAL
OVERALL O.D.
INCHES

mm

APPROXIMATE NET
WEIGHT
LBS/
1000 FT

AMPACITY

kg/
DIRECT
1000 m IN AIR¹ BURIAL²

3/C WITH GROUND MC-HL OR MV-105, 345 MILS EPR, 25 kV 133% AND 35 kV 100% INSULATION LEVEL³
9855.00103104

1 (19/W)
(42.4 mm²)

3

345 8.8

1.04 26.4

4

2.48 63.0 2.89

73.4

75

1.91

3.05

77.5

4,100

6,101

210

225

9855.11003104

1/0 (19/W)
(53.5 mm²)

3

345 8.8

1.07 27.2

4

2.56 65.0 2.98

75.7

75

1.91

3.14

79.8

4,500

6,697

240

255

9855.21003104

2/0 (19/W)
(67.4 mm²)

3

345 8.8

1.11 28.2

4

2.65 67.3 3.11

79.0

85

2.16

3.30

83.8

4,950

7,366

275

290

9855.41003103

4/0 (19/W)
(107 mm²)

3

345 8.8

1.22 31.0

3

2.88 73.2 3.41

86.6

85

2.16

3.60

91.4

6,200

9,227

360

345

9855.25003103

250 (37/W)
(127 mm²)

3

345 8.8

1.27 32.3

3

2.97 75.4 3.63

92.2

85

2.16

3.81

96.8

6,800 10,119

400

410

9855.35003102

350 (37/W)
(177 mm²)

3

345 8.8

1.36 34.5

2

3.20 81.3 3.76

95.5

85

2.16

3.94 100.1

8,000 11,905

490

495

9855.50003101

500 (37/W)
(253 mm²)

3

345 8.8

1.48 37.6

1

3.45 87.6 4.10 104.1

85

2.16

4.23 107.4 10,150 15,105

600

590

Dimensions and weights are nominal; subject to industry tolerances.
¹ In-air ampacities are per NEC Table 310.60(C)(71) for three insulated copper conductors rated 105°C, cabled with an overall covering and isolated in air at 40°C ambient temperature.
² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors rated 105°C, cabled within an overall covering and directly buried in earth at 20°C
ambient earth temperature.
³ Catalog number 9855.00103104, 1 AWG, 3 conductor is only listed 25 kV 133% insulation level in accordance with UL 1072.

Phone: 888-593-3355
www.generalcable.com

SPEC 9875

February, 2011

CCW Armored Power, 35 kV 133%, Shielded, 3/C
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC

Product Construction:
Conductor:
•	Bare annealed copper per ASTM B3
•	Compact stranding per ASTM B496
Extruded Strand Shield (ESS):
•	Extruded thermoset semi-conductor
stress control layer over the conductor
per ICEA S-93-639 and UL 1072
Insulation:
•	420 mils Ethylene Propylene Rubber
(EPR) insulation per ICEA S-93-639
and UL 1072
Extruded Insulation Shield (EIS):
•	Thermoset semi-conducting polymeric
layer, free stripping from the insulation
per ICEA S-93-639 and UL 1072
Shield:
•	5 mil annealed bare copper tape with
25% overlap
Phase Identification:
•	Color-coded polymeric identification
tape laid under the shield - black, red
and blue
Grounding Conductor:
•	Class B stranded bare annealed
copper grounding conductor
•	Sized in accordance with UL 1072 and
NEC Article 250
Cable Assembly:
•	Insulated and grounding conductors
are cabled together with nonhygroscopic fillers when required
•	Binder tape is applied over the cabled
core
CCW Armor:
•	Impervious, continuously welded and
corrugated aluminum alloy sheath per
UL 1072 and UL 1569
•	CCW armor conductivity meets the
grounding requirements of the NEC

Phone: 888-593-3355
www.generalcable.com

Jacket:
•	Flame-retardant, moisture- and
sunlight-resistant Polyvinyl Chloride
(PVC) per UL 1072, orange
•	Low temperature performance meets
ASTM D746 brittleness temperature at
or below -40°C

Applications:
•	CCW armored Medium-Voltage
power cables offer an economical,
rugged and reliable alternative to
labor-intensive cable in conduit wiring
methods
•	For use on feeders and branch circuits
in industrial power distribution systems
per NEC Articles 328 and 330
•	For use in Class I, II and III, Divisions
1 and 2; and Class I, Zones 1 and 2
hazardous locations per NEC Articles
501, 502, 503 and 505
•	Installed on metal racks, troughs, in
raceways, in cable trays or secured
to supports spaced not more than six
feet apart
•	Installed in both exposed and
concealed work, wet or dry locations,
directly buried or embedded in
concrete
•	Recognized for use on fixed or
floating offshore petroleum facilities
as recommended by the American
Petroleum Institute

Features:
•	CCW armor provides an impervious
barrier to moisture, gas and liquids
and meets the grounding requirements
of UL 1072 and the NEC
•	Triple Extrusion: The strand shield,
EPR insulation and insulation shield
are all extruded in one operation

Features: (cont’d)
•	General Cable’s EPR insulation system
has outstanding corona resistance and
high dielectric strength, and it provides
electrical stability under stress
•	Cable meets cold impact at -40°C
•	105˚C continuous operating
temperature, wet or dry
•	140˚C emergency rating
•	250˚C short circuit rating

Specifications:
Design Adherence:
•	ICEA S-93-639/WC74, 5-46 kV
Shielded Power Cable
•	AEIC CS8 Specification for Shielded
Power Cable, 5-46 kV
•	UL 1072 Medium-Voltage Power
Cables
•	UL 1569 Metal Clad Cables
•	UL 2225 Cables and Cable Fittings for
Use in Hazardous Locations
•	UL 1309 Marine Shipboard Cable
Flame Tests:
•	ICEA T-29-520 (210,000 BTU/hr)
•	IEEE 383 (70,000 BTU/hr)
•	CSA FT4
•	IEEE 1202 (70,000 BTU/hr)
•	UL 1072
•	IEC 60332-3 Category A
Compliances:
•	UL Type MV-105, UL File # E90501
•	UL Type MC-HL, SUN RES, CT
USE, DIR BUR, -40°C, FT4, UL File #
E90496
•	UL Listed Marine Shipboard, UL File #
E85994
•	American Bureau of Shipping (ABS)
Listed for CWCMC

SPEC 9875

February, 2011

CCW Armored Power, 35 kV 133%, Shielded, 3/C
®

UL Type MC-HL or MV-105, EPR, 105°C, Cable Tray Use, Sunlight-Resistant
Direct Burial, ABS CWCMC
COND.
SIZE
CATALOG
NUMBER

AWG
(kcmil)

INSULATION
THICKNESS
NO. OF
COND. mils

NOMINAL O.D.
OVER
BARE
INSULATION GROUND

mm INCHES mm

NOMINAL
CORE O.D.

NOMINAL
ARMOR O.D.

AWG INCHES mm INCHES mm

JACKET
THICKNESS
mils

mm

NOMINAL
OVERALL O.D.
INCHES

mm

APPROXIMATE NET
WEIGHT
LBS/
1000 FT

AMPACITY

kg/
DIRECT
1000 m IN AIR¹ BURIAL²

3/C WITH GROUND MC-HL OR MV-105, 420 MILS EPR, 35 kV 133% INSULATION LEVEL
9875.11003104

1/0 (19/W)
(53.5 mm²)

3

420 10.7 1.24 31.5

4

2.91 73.9 3.41 86.6

85

2.16

3.59

91.2

5,300

7,887

240

255

9875.21003104

2/0 (19/W)
(67.4 mm²)

3

420 10.7 1.27 32.3

4

3.02 76.7 3.63 92.2

85

2.16

3.81

96.8

6,000

8,929

275

290

9875.41003103

4/0 (19/W)
(107 mm²)

3

420 10.7 1.38 35.1

3

3.23 82.0 3.80 96.5

85

2.16

3.98 101.1

7,100 10,566

360

345

9875.25003103

250 (37/W)
(127 mm²)

3

420 10.7 1.43 36.3

3

3.40 86.4 3.98 101.1 85

2.16

4.16 105.7

8,100 12,054

400

410

9875.35003102

350 (37/W)
(177 mm²)

3

420 10.7 1.52 38.6

2

3.51 89.2 4.10 104.1 85

2.16

4.29 109.0

9,000 13,393

490

495

9875.50003101

500 (37/W)
(253 mm²)

3

420 10.7 1.64 41.7

1

3.81 96.8 4.45 113.0 85

2.16

4.63 117.6 11,100 16,519

600

590

Dimensions and weights are nominal; subject to industry tolerances.
¹ In-air ampacities are per NEC Table 310.60(C)(71) for three insulated copper conductors rated 105°C, cabled with an overall covering and isolated in air at 40°C ambient temperature.
² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors rated 105°C, cabled within an overall covering and directly buried in earth at 20°C
ambient earth temperature.

Phone: 888-593-3355
www.generalcable.com

SPEC 9900

January, 2010

CCW Armored Cable Tool Kit
®

For Removal of CCW Armor Sheath
Including Accessories

Tool Kit Contents:
•	 1 ea. Kett-Tool Metal Clad Cable Saw
•	 12 pcs. 2" / 44 teeth Cutting Blades
•	 Cable Saw Spindle and Allen Wrenches
•	 1 ea. MC Cable Guide
•	 1 ea. Tubing and Pipe Cutter
•	 1 ea. 12" V-Jaw Channel-Lock Pliers
•	 1 ea. 10" Hacksaw Frame
•	 3 ea. 10" / 24 teeth/in. Hacksaw Blades
•	 1 ea. 10 ft. Tape Measure
•	 1 ea. Utility Knife with Blades
•	 1 ea. 5/16" Screwdriver
•	 1 ea. Tool Box

Phone: 888-593-3355
www.generalcable.com

CATALOG NUMBER

QUANTITY

DESCRIPTION

APPROXIMATE
WEIGHT

9900.KS226

1

CCW TOOL KIT WITH 120 V AC,
60Hz ELECTRIC CUTTING SAW

22.0 LBS

9900.PS526

1

CCW TOOL KIT WITH 90 PSI
PNEUMATIC CUTTING SAW

20.0 LBS

9900.15744

1

2", 44T REPLACEMENT CUTTING BLADES
(12 BLADES PER PACK)

1.0 LBS

9900.27901

1

MC CABLE GUIDE

0.5 LBS

Industrial Cables	

Date of Issue 06/13

Technical Information
Section A

General Technical Information

SPECIFICATION NO.

DESCRIPTION

A005

Glossary

Jan. 2010

A025

Reference Standards

Jan. 2010

A050

Checklist for Specifications

Jan. 2010

A075

NEC and CSA Designations

Jan. 2010

A100

Common Color Sequence

May 2013

A150

Metric Conversion Factors

Sept. 2010

A200

Reel Capacity Chart

Jan. 2012

Section B

Conductor Data

SPECIFICATION NO.

DESCRIPTION

B005

Conductor Reference

Jan. 2010

B025

Class B Conductors for General Wiring

Mar. 2012

B030

Class C Conductors for General Wiring

Feb. 2011

B035

Class H Conductors for General Wiring

Feb. 2011

B040

Class I Conductors for General Wiring

Mar. 2012

B045

Class K Conductors for General Wiring

Mar. 2012

Section C

Material Properties

SPECIFICATION NO.

DESCRIPTION

C005

Thermoplastic Jacket and Insulation Material Properties

Sept. 2012

C010

Thermoset Jacket and Insulation Material Properties

Jan. 2010

Section D

Handling and Storage Recommendations

SPECIFICATION NO.

DESCRIPTION

D005

Recommended Reel Handling Practices

May 2013

D025

Recommended Cable Handling Practices

Oct. 2011

D050

Recommended Cable Storage Practices

May 2013

REVISION DATE

REVISION DATE

REVISION DATE

REVISION DATE

Phone: 888-593-3355
www.generalcable.com

Date of Issue 06/13 	

Industrial Cables

Technical Information
Section E

Cable Installation Guidelines

SPECIFICATION NO.

DESCRIPTION

E005

Pre-Installation Instructions

Apr. 2010

E025

Installation — Overview and Checklist

Jan. 2011

E050

Installation — Feed-In Setups

Apr. 2010

E075

Installation — Conductor Maximum Pulling Tensions

Oct. 2012

E100

Installation — Training and Bending Limitations

Apr. 2010

E125

Installation — Maximum Sidewall Pressure

Oct. 2012

Section F

Cable Testing

SPECIFICATION NO.

DESCRIPTION

F005

DC “HI-POT” Pre-Test Guidelines for MV Cables

Apr. 2010

F025

DC “HI-POT” Testing Guidelines for MV Cables

Apr. 2010

F075

Field Electrical “HI-POT” Testing Guidelines

Apr. 2010

F100

Emergency Overload Current Guidelines

Jan. 2010

F125

Short Circuit Current Calculation Overview

Jan. 2010

F150

Short Circuit Current for Copper Shields

Jan. 2010

F175

AC Resistance & Inductive Reactance

Jun. 2013

Phone: 888-593-3355
www.generalcable.com

REVISION DATE

REVISION DATE

SPEC A005
January, 2010

Glossary
Abrasion Resistance: Ability of a wire,
cable or material to resist surface
wear.

Analog: A data format using continuous
physical variables such as voltage
amplitude or frequency variations.

Accelerated Aging: A test in which
voltage, temperature, etc. are
increased above normal operating
values to obtain observable
deterioration in a relatively short
period of time. The plotted results
give expected service life under
normal conditions.

Anneal (Soften): Relief of mechanical
stress through heat and gradual
cooling. Annealing copper renders it
less brittle.

ACM: Aluminum conductor material.
Accelerator: A chemical additive that
hastens a chemical reaction under
specific conditions.
Admittance: The measure of the ease
with which an alternating current
flows in a circuit. The reciprocal of
impedance.
AEIC: Association of Edison Illuminating
Companies
Aerial Cable: A cable suspended in the
air on poles or another overhead
structure.
Aging: The change in properties of a
material with time under specific
conditions.
AIA: Aluminum Interlocked Armor.
Alloy: A metal formed by combining two
or more different metals to obtain
desirable properties.
Alternating Current: Electric current that
continually reverses its direction. It
is expressed in cycles per second
(hertz or Hz).
Ambient Temperature: The temperature
of the medium surrounding an object.
Generally a lower temperature than
the temperature at which the cable is
operating.
American Wire Gauge (AWG): A
standard North American system for
designating wire diameter.
Ampacity: See Current Carrying Capacity.
Ampere: The unit of current. One ampere
is the current flowing through
one ohm of resistance at one volt
potential.

Armor: A protective metal covering
commonly in the form of flexible
interlocking aluminum or steel tape,
steel wires or aluminum sheath.
ASTM: American Society for Testing and
Materials.
Attenuation: The general term used to
denote the decrease of power from
one point to another. In fiber optics,
the optical power loss per unit
length is expressed logarithmically in
decibels per kilometer (dB/km) at a
specific wavelength.
Audio Frequency: The range of
frequencies audible to the human ear.
Usually 20-20,000 Hz.
AWM: Designation for appliance wiring
material.
Balanced Circuit: One utilizing cables
having two or more identical
conductors with the same
electromagnetic characteristics in
relation to each other and to ground.
Band Marking: A continuous
circumferential band applied to a
conductor at regular intervals for
identification.
Bandwidth: (1) The difference between
the upper and lower limits of a given
band of frequencies. Expressed in
Hertz. (2) A measure of the maximum
frequency range over which light
intensity exiting a waveguide one kilo­
meter in length can be varied before
the attenuation varies 3 dB from the
mean. The greater the bandwidth,
the greater the information-carrying
capacity. Bandwidth is expressed in
Megahertz (MHz)–Kilometer (km).
Bending Radius: Radius of curvature that
a cable can be safely bent without
any adverse effects.

Binder: A spirally served tape used
for holding assembled cable
components in place awaiting
subsequent manufacturing
operations.
Bonding Conductor: An insulated or
uninsulated conductor forming part
of the cable assembly which is used
for the purpose of connecting noncurrent carrying parts of electrical
equipment to a system grounding
conductor.
Braid: A fibrous or metallic group of
filaments interwoven in cylindrical
shape to form a covering over one or
more wires.
Braid Angle: The smaller of the two
angles formed by the shielding
strand and the axis of the cable
being shielded.
Braid Carrier: A spool or bobbin on
a braider that holds one group of
strands or filaments consisting of a
specific number of ends. The carrier
revolves during braiding operations.
Braid Ends: The number of strands used
to make up one carrier. The strands
are wound side-by-side on the carrier
bobbin and lie parallel in the finished
braid.
Breakdown Voltage: The voltage at
which the insulation between two
conductors breaks down.
B & S Gauge: The same as American
Wire Gauge (AWG).
Buffer: A protective coating over an
optical fiber.
Building Wire: A general term used for
light and power wiring products,
1000 volts or less.
Bunch Stranding: A group of wires of
the same diameter twisted together
without a predetermined pattern.
Used in flexible cords and cables.
Buried Cable: A cable installed directly in
the earth without use of underground
conduit. Also called “direct burial
cable.”
Butyl Rubber: A synthetic rubber with
good insulating properties (i.e. low
voltage cords).

Phone: 888-593-3355
www.generalcable.com

SPEC A005
January, 2010

Glossary
Cable: An insulated conductor, or group
of individually insulated conductors
in one assembly.

Coaxial Cable: A cable consisting of two
cylindrical conductors with a common
axis, separated by a dielectric.

Cabling: The twisting together of two or
more insulated conductors to form a
cable.

Cold Flow: Permanent deformation of the
insulation or jacket due to mechanical
force or pressure (not due to heat
softening).

Capacitance: The ratio of the
electrostatic charge on a conductor
to the potential difference between
the conductors required to maintain
that charge. Units expressed in
Farads.
Capacitive Coupling: Electrical
interaction between two conductors
caused by the capacitance between
them.
Capacitive Reactance (Xc): The
opposition to alternating current due
to the capacitance of the cable or
circuit. Measured in ohms.
CE Code, CEC: Canadian Electrical Code
Certified Test Report (CTR): A report
providing actual test data on a
cable. Tests are normally conducted
by the Quality Control Department
to confirm that the product being
shipped conforms to specifications.

Color Code: A system for circuit
identification through use of solid
colors and contrasting tracers.
Composite Cable: One containing
more than one type or gauge size of
conductors (e.g. power and control
conductors in one assembly).
Compound: An insulating or jacketing
material made by mixing two or more
polymeric ingredients.
Concentric Stranded Conductors:
Manufactured to ASTM, ICEA and
CSA standards. The most common
fixed installation type conductors are:
1) Round—no diameter reduction;
2) Compressed—approximately 3%
diameter reduction; 3) Compact—
approximately 10% diameter
reduction.

Connector: A device used to physically
and electrically connect two or more
conductors. Also used to physically
connect cable to equipment.
Continuity Check: A test to determine
whether electrical current flows
continuously throughout the length
of a single wire or individual wires in
a cable.
Continuous Vulcanization: Simultaneous
extrusion and vulcanization of rubberlike (thermoset) coating materials.
Often referred to as CV.
Control Cable: A multi-conductor cable
made for operation in control of
signal circuits.
Copolymer: A compound resulting from
the polymerization of two different
monomers.
Copperweld : The trade name of Flexo
Wire Division (Copper­weld Steel
Corp.) for its copper-clad steel
conductors.
®

Cord: A small, flexible, insulated wire or
cable.

Characteristic Impedance: The
impedance that, when connected to
the output terminals of a transmission
line of any length, makes the line
appear infinitely long. The ratio of
voltage to current at every point along
a transmission line on which there are
no standing waves.

Concentric Stranding: A central wire
surrounded by one or more layers
of helically wound strands in a fixed
round geometric arrangement.

Core: In cables, a component or
assembly of components over which
additional components (shield,
sheath, etc.) are applied.

Concentricity: The measurement of
the location of the center of the
conductor with respect to the
geometric center of the surrounding
insulation.

Corona: A discharge due to ionization
of air around a conductor due to a
potential gradient exceeding a certain
critical value.

Circular Mil (cmil): The area of a circle
one mil (.001") in diameter (7.854 x
10-7 sq in). Used in expressing wire
cross-sectional area.

Conductivity: The capacity of a material
to carry electrical current—usually
expressed as a percentage of copper
conductivity (copper being 100%).

Circuit Sizes: A popular term for building
wire sizes 14 through 10 AWG.

Conductor: An uninsulated wire suitable
for carrying electrical current.

Cladding: (1) A method of applying a
layer of metal over another metal
whereby the junction of the two
metals is continuously welded. (2)
A low refractive index material that
surrounds the core of an optical fiber
causing the transmitted light to travel
down the core and protects against
surface contaminant scattering.

Conductor Shield: An extrusion of black
semi-conducting thermoses material
over the conductor to provide a
smooth interface with the insulation
for even distribution of electrical
stress.

Phone: 888-593-3355
www.generalcable.com

Conduit (Electrical Raceway): A tube
or pipe in which insulated wires and
cables are run.

Coverage: The percent of completeness
with which a metal serving covers the
underlying surface.
CPE: Chlorinated polyethylene can be
used as either a thermoplastic or
thermoset. It is a tough chemical- and
oil-resistant material and makes an
excellent jacket for industrial control
cable. As a thermoset, it can be used
as an oil-resistant cord jacket. Typical
temperature ratings range from -35˚C
to 90˚C. Other outstanding properties
include low water absorption and
super crush resistance, which are
important attributes in industrial
control applications.
Creep: The dimensional change with time
of a material under a mechanical load.

SPEC A005
January, 2010

Glossary
Cross-linked: Inter-molecular bonds
between long-chain thermoplastic
polymers by chemical or electron
bombardment means. The properties
of the resulting thermosetting material
are usually improved (e.g. XLPE).
Crosstalk: Signal interference between
nearby conductors caused by pickup
of stray energy.
CSA: Canadian Standards Association
Current Carrying Capacity (Ampacity):
The maximum current an insulated
conductor can safely carry without
exceeding its insulation and jacket
temperature limitations.
Cut-Through Resistance: The ability of
a material to withstand cutting from
a sharp edge or small radius under
pressure.
Decibel (dB): A unit to express differences
of power level. Used to express power
gain in amplifiers or power loss in
passive circuits or cables. The units in
which the ratio of two power levels, P1
and P2, are expressed. The ratio in
dB is given as - 10 log10 (P1/P2).
		 P2 → → P1
Delay Line: A cable made to provide very
low velocity of propagation with long
electrical delay for transmitted signals.
Derating Factor: A factor used to reduce
the current carrying capacity of a wire
when used in environments other
than that for which the value was
established.
Dielectric: Any insulating material
between two conductors that permits
electrostatic attraction and repulsion
to take place across it.
Dielectric Constant (K): The ratio of the
capacitance of a condenser with
dielectric between the electrodes to
the capacitance when air is between
the electrodes. Also called Permittivity
and Specific Inductive Capacity (SIC).
Dielectric Strength: The voltage which
an insulation can withstand before
breakdown occurs. Usually expressed
as a voltage gradient (such as volts
per mil).

Dielectric Test: A test in which a voltage
higher than the rated voltage is
applied for a specified time to
determine the adequacy of the
insulation under normal conditions.
Sometimes called a “Hi-Pot” test (high
potential).
Digital: A data format that uses discrete
or separate physical levels to contain
information.
Direct Burial Cable: A cable installed
directly in the earth.
Direct Current: An electric current that
flows in only one direction.
Direction of Lay: The lateral direction in
which the strands of a conductor run
over the top of the cable conductor as
they recede from an observer looking
along the axis of the conductor or
cable. Also applies to twisted cable.
Dissipation Factor: The tangent of the
loss angle of the insulating material.
(Also referred to as loss tangent, tan
d and approximate power factor.)
Drain Wire: The uninsulated wire
in contact with an electrostatic
shield throughout its length, in an
instrumentation or control cable,
used to discharge unwanted signals.
Also provides a means of terminating
laminated shields. Sometimes used
to describe the metallic shielding
wires of a power cable insulation
shield.
Drawing: In wire manufacturing, pulling
the metal through a die or series
of dies to reduce diameter to a
specified size.
Earth: British terminology for zeroreference “ground.”
Eccentricity: Like concentricity,
a measure of the center of a
conductor’s location with respect
to the circular cross section of
the insulation. Expressed as a
percentage of displacement of one
circle within the other.
EEMAC: Electrical and Electronic
Manufacturers Association of Canada
(U.S. counterpart is NEMA).

Elastomer: A rubber-like substance. Any
material that will return to its original
dimensions after being stretched or
distorted.
Electrostatic Shield: A copper or
laminated aluminum/Mylar tape wrap
around a signal or instrumentation
circuit (pair, triad, etc.) to protect
from the electric field radiated by a
voltage source. The grounded shield
intercepts static interference and
carries it off to ground.
®

Elongation: The fractional increase in
length of material stressed in tension.
EMI: Abbreviation for electromagnetic
interference.
EMRC: Energy Mines and Resources
Canada
EPDM: Ethylene-propylene-diene
monomer rubber. A material with
good electrical insulating properties.
EPR: Ethylene-propylene copolymer
rubber. A material with good
electrical insulating properties.
Equal Load Sharing: An even distribution
of current between the parallel
cables in a power circuit.
Equilay: See Unilay: More than one layer
of helically laid wires with the length
of the lay the same for each layer.
Farad: A unit of electrical capacity.
Fatigue Resistance: Resistance to
metal crystallization which leads to
conductors or wires breaking from
flexing.
Ferrous: Composed of and/or containing
iron. A ferrous metal exhibits
magnetic characteristics (e.g. steel
armor).
FEP: Fluorinated ethylene propylene
insulated wire (see Teflon ).
®

Fiber: A single, separate optical
transmission element c
­ haracterized
by core and cladding.
Fiber Optics: Light transmission through
optical fibers for communication and
signaling.

Phone: 888-593-3355
www.generalcable.com

SPEC A005
January, 2010

Glossary
Filled Cable: Cable construction in which
the cable core is filled with a material
that will prevent moisture or gasses
from entering or passing through the
cable.
Filler: 1) A material used in multiconductor cables to occupy large
interstices formed by the assembled
conductors; 2) An inert substance
added to a compound to improve
properties.
Flat Cable: A cable with two essentially
flat surfaces (e.g., NMD90).
Flat Conductor: A wire having a
rectangular cross section as
opposed to round or square
conductors.
Flame Resistance: The ability of a
material not to propagate flame
once the heat source is removed (see
FT1).
Flammability: The measure of the
material’s ability to support
combustion.
Flex Life: The measurement of the ability
of a conductor or cable to withstand
repeated bending before breaking.
Flexibility: The ease with which a cable
may be bent without sustaining
damage.
FT1: One of several CSA flame test
designations for wires and cables
which pass the C22.2 No. 0.3 test
requirements. (Other designations
include FT2, FT4, etc.).
Fusion Splice: A splice accomplished
by the application of localized heat
sufficient to fuse or melt the ends of
two lengths of optical fiber, forming a
continuous single fiber.
Gauge: A term used to denote the
physical size of a wire.
GND: Abbreviation for ground.
Graded-Index: A type of optical fiber in
which the refractive index of the core
is in the form of a parabolic curve,
decreasing toward the cladding. This
type of fiber provides high bandwidth
capabilities.

Phone: 888-593-3355
www.generalcable.com

Ground (GND): 1) A conducting
connection between an electrical
circuit and the earth, or other large
conducting body, to serve as an
earth thus making a complete
electrical circuit; 2) Term used for
non-current carrying conductor in a
cable (see Bonding Conductor).
Halogen: A term used to identify any of
the four elements chlorine, fluorine,
bromine and iodine, grouped
together because their chemical
properties are similar.
Hard Drawn Copper Wire: Copper wire
that has not been annealed after
drawing.
Heat Shock: A test to determine stability
of a material by sudden exposure to
a high temperature for a short period
of time.
Henry: The unit of inductance.
Hertz (Hz): A term replacing cycles-persecond as an indication of frequency.
Hi-Pot (High Potential): A test
designated to determine the highest
voltage that can be applied to a
conductor without breaking down the
insulation (see Dielectric Test).
High Voltage (HV): Generally, a wire or
cable with an operating voltage of
over 600 volts.
Hook-Up Wire: A wire used for low
current, low voltage (under 1000
volts) applications within enclosed
electronic equipment.
Hygroscopic: A material capable of
absorbing moisture from the air.
Hypalon : DuPont’s trade name for their
chlorosulfonated polyethylene, an
ozone-resistant synthetic rubber.
®

ICEA (formerly IPCEA): Insulated Cable
Engineers Association.
IEEE: Institute of Electrical and
Electronics Engineers.
Impact Strength: A test for determining
the mechanical punishment a cable
can withstand without physical or
electrical breakdown by impacting
with a given weight, dropped a given
distance, in a controlled environment.

Impedance: The total opposition that a
circuit offers to the flow of alternating
current or any other varying current
at a particular frequency. It is a
combination of resistance R and
reactance X, measured in ohms.
Inductance: The property of a circuit
or circuit element that opposes a
change in current flow, thus causing
current changes to lag behind voltage
changes. It is measured in henrys.
Insulation: A material having good
dielectric properties permitting close
assembly of conductors in cable and
equipment.
Insulation Level: A designation used
to identify the insulation thickness
required to protect a high voltage
cable under ground fault conditions.
Expressed as a percentage (e.g.
100% level, 133% level).
Insulation Shield (HV Cable): A twopart shield consisting of a nonmetallic component and a metallic
component. The first component
is an extrusion of black semiconducting thermoset material over
the insulation, which provides uniform
radial stress distribution across the
insulation. The second component
is a metallic shield which is typically
copper tape or wire that functions
as a bonding (grounding) conductor
and/or a neutral conductor. The
metallic shield also serves to conduct
ground fault current in the event of
insulation failure. See also Drain Wire.
Insulation Stress: High voltage stress
which causes molecular separation
in the insulation at sharp projections
in the conductor. Controlled by
conductor and insulation shielding,
called a stress relief shield. Measured
in volts per mil.
Interaxial Spacing: Center-to-center
conductor spacing.
Interstices: Voids or valleys between
individual strands in a conductor or
between insulated conductors in a
multi-conductor cable (intersticial
spaces).

SPEC A005
January, 2010

Glossary
Irradiation: In insulations, the exposure of
the material to high energy emissions
for the purpose of favorably
altering the molecular structure by
crosslinking.

mA. Milliampere: One-thousandth of an
ampere (10-3 ).

Jacket: An outer covering, usually nonmetallic, mainly used for protection
against the environment.

Magnetic Noise: Caused by current
frequency. An AC powerline creates a
magnetic field around that cable, this
magnetic field causes the magnetic
noise in neighboring control or
instrumentation circuits.

kcmil: One thousand circular mils (MCM).

MCM: One thousand circular mils (kcmil).

kilo: A prefix denoting 1000

meg or mega: A prefix denoting
1,000,000 (10 6 ).

(103 ).

kV: Kilovolt (1000 volts).
Laminated Tape: A tape consisting
of two or more layers of different
materials bonded together (e.g.
aluminum/Mylar ).
®

Lay: The length measured along the axis
of a wire or cable required for a single
strand (in stranded wire) or conductor
(in cable) to make one complete turn
about the axis of the conductor or
cable.

Megarad: A unit for measuring radiation
dosage.
Messenger: The linear supporting
member, usually a high-strength steel
wire, used as the supporting element
of a suspended aerial cable. The
messenger may be an integral part of
the cable, or exterior to it.
Mho: The unit of conductivity. The
reciprocal of an ohm.

Mutual Capacitance: Capacitance
between two conductors when all
other conductors, including ground,
are connected together.
Mylar : DuPont trade name for a
polyester material.
®

Nano: A numerical prefix denoting onebillionth (10-9 ).
National Electrical Code (NEC): A U.S.
consensus standard published by the
National Fire Protection Association
(NFPA) and incorporated in OSHA
regulations. (Canadian Counterpart is
the CE Code).
NEMA: National Electrical Manufacturers
Association. (Canadian counterpart
is EEMAC).
Neoprene: A synthetic rubber with good
resistance to oil, chemicals and
flame. Also called polychloroprene.
Nomex : DuPont trademark for a
temperature-resistant, flameretardant nylon.
®

Lay Direction: The twist in the cable as
indicated by the top strands while
looking along the axis of the cable
away from the observer. Described as
“right hand” or “left hand.”

micro: A prefix denoting one-millionth
(10-6 ).
micron: (m) Millionth of a meter = 10-6
meter.

Non Hygroscopic: A material incapable
of taking up or absorbing moisture
from the air.

Leakage Current: The undesirable flow
of current through or over the surface
of an insulation.

Mil: A unit of length equal to onethousandth of an inch (.001").
Common unit for insulation
thickness.

Nylon : An abrasion-resistant
thermoplastic with good chemical
resistance. A DuPont registered
trademark.

Milli: A prefix denoting one-thousandth
(10-6 ).

OHM: The electrical unit of resistance.

Line Drop (Voltage Drop): A voltage loss
occurring between any two points in
a power circuit. Such loss, or drop,
is due to the resistance, reactance or
leakage of the circuit, type of cable
and configuration.

Modulus of Elasticity: The ratio of stress
to strain in an elastic material.

Line Voltage: The value of the potential
existing on a supply or power line.
Rated voltage of cables.

Moisture Absorption: The amount
of moisture, in percentage, that a
material will absorb under specified
conditions.

LOCA: Abbreviation for loss of coolant
accident, a system malfunction
associated with nuclear generating
stations.

Moisture Resistance: The ability of a
material to resist absorbing moisture
from the air or when immersed in
water.

Longitudinal Shield: A tape shield, flat
or corrugated, applied longitudinally
with the axis of the core being
shielded.

Multi-Conductor Cable: A cable
consisting of two or more
conductors, either cabled or laid in
a flat parallel construction, with or
without a common overall covering.

Loss Factor: The product of the
dissipation and dielectric constant of
an insulating material.
µA. Microampere: One-millionth of an
ampere (10-6 ).

Multi-Plexed Conductors: Three or more
completed cables together without
fillers or common overall jacket.
(Triplexed, 3-1|C; Quadruplet, 4-1|C)

®

OSHA: Abbreviation for the U.S.
Occupational Safety and Health Act.
Overlap: The amount the trailing edge
laps over the leading edge of a spiral
tape wrap.
Oxygen Index: Percentage of oxygen
necessary to support combustion
in a gas mixture. Flame-retardant
materials have a higher oxygen index.
Pair: Two insulated wires of a single
circuit twisted together or laid
parallel.
Parallel Cable: Two or more cables used
to share the current in heavily loaded
power circuits which permits the use
of smaller conductors.

Phone: 888-593-3355
www.generalcable.com

SPEC A005
January, 2010

Glossary
Percentage Conductivity: Conductivity
of a material expressed as a
percentage of that of copper. Also
used to indicate ratio of conductance
between the phase conductor and
the neutral in power cables.
Pick: Distance between two adjacent
crossover points of braid filaments.
The measurement in picks per inch
indicates the degree of coverage.
pico: A prefix denoting one-millionth of
one-millionth (10-12 ).
Pitch: In flat cable, the nominal distance
between the index edges of two
adjacent conductors.
Pitch Diameter: Diameter of a circle
passing through the center of the
conductors in any layer of a multiconductor cable.
Plastic Deformation: Change in
dimensions under load that is not
recovered when the load is removed.
Plasticizer: A chemical agent added to
plastics to make them softer and
more pliable.
Plenum Cable: Cable approved for
installation in plenums (e.g.,
suspended ceiling) without the need
for conduit.
Polyester: Polyethylene terephthalate
which is used extensively in the
production of a high-strength,
moisture-resistant film used as a
cable core wrap (see Mylar ).
®

Polyethylene (PE): A thermoplastic
material having excellent electrical
and physical properties.
Polymer: A material of high molecular
weight formed by the chemical union
of monomers.
Polyolefin: A family of thermoplastics
based upon the unsaturated
hydrocarbons know as olefins. When
combined with butylene or styrene
polymers, they form compounds such
as polyethylene and polypropylene.
Polypropylene (PPE): A thermoplastic
similar to polyethylene but stiffer
and having a higher softening point
(temperature).

Phone: 888-593-3355
www.generalcable.com

Polyurethane/PUR: This thermoplastic
material is used primarily as a cable
jacket material. It has excellent
oxidation, oil and ozone resistance.
Some formulations also have good
flame resistance. It is a hard material
with excellent abrasion resistance.
It has outstanding “memory”
properties, making it an ideal jacket
material for retractile cords.
Polyvinyl Chloride (PVC): A generalpurpose thermoplastic used for low
voltage wire and cable insulation, and
for jackets.
Power Factor: The ratio of resistance to
impedance. The ratio of the actual
power of an alternating current to
apparent power. Mathematically,
the cosine of the angle between
the voltage applied and the current
resulting.
Primary Insulation: The first layer of nonconductive material applied over a
conductor, whose prime function is to
act as electrical insulation.
Pulling Eye: A device fastened to a cable
to which a hook may be attached in
order to pull the cable.
Quad: Four insulated wires of a single
circuit.
REA: Rural Electrification Administration.
A branch of the U.S. Department of
Agriculture.
Reactance: The opposition offered to
the flow of alternating current by
inductance or capacitance of a
component or circuit.
Reel Drum Diameter: Diameter of the
drum (or hub) of the reel.
Reel Flange Diameter (Reel Height):
Diameter of the reel flanges.
Reel Traverse: Width of space between
reel flanges.
Reel Width: Overall width of reel.
Ridge Marker: One or more ridges
running laterally along the outer
surface of a insulated wire or cable
for purposes of identification.
Root Mean Square (RMS): The effective
value of an alternating current or
voltage.

Rope Lay Conductor: A conductor
composed of a central core
surrounded by one or more layers of
helically laid groups of wires used in
portable cables.
Rubber: A general term used to describe
wire insulation and jackets made of
thermosetting elastomers, such as
natural or synthetic rubbers, EPR,
neoprene, Hypalon, butyl rubber and
others.
SBR: A copolymer of styrene and
butadiene. Also GR-S or Buna-S.
Most commonly used type of
synthetic rubber.
Self-Extinguishing: The characteristic
of a material whose flame is
extinguished after the igniting flame
is removed.
Semi-Conductor: In wire industry
terminology, a material possessing
electrical conductivity that falls
somewhere between that of
conductors and insulators. Usually
made by adding carbon particles to
an insulator (e.g. conductor shield
and insulation shield). Not the same
as semi-conductor materials such
as silicon, germanium, etc. used for
making transistors and diodes.
Separator: Pertaining to wire and cable,
a layer of insulating material such
as textile paper, Mylar , etc. which
is placed between a conductor and
its dielectric, between a cable jacket
and the components it covers or
between various components of a
multi- conductor cable. It can be
utilized to improve stripping qualities,
flexibility or can offer additional
mechanical or electrical protection to
the components it separates.
®

Served Wire Armor (SWA): Spiral wrap
of galvanized steel wires applied
around a cable to afford mechanical
protection and increase the cable
pulling tension characteristics
(mineshaft, submarine cable, etc.).
Also used to denote steel wire armor.
Sheath: The outer covering or jacket of a
multi-conductor cable. Usually nonmetallic.

SPEC A005
January, 2010

Glossary
Shield (Electrostatic): In cables, a
metallic layer placed around a
conductor or group of conductors
to prevent electrostatic interference
between the enclosed wires and
external fields. Also see Insulation
Shield.
Shrink Tubing: Tubing which has
been extruded, crosslinked and
mechanically expanded which, when
reheated, will return to its original
diameter.
SIA: Steel Interlocked Armor.
Side Wall Bearing Pressure (SWBP):
A term used in reference to the
pressure on a cable which is being
pulled around a curved surface
under tension. If excessive, SWBP
can damage cable components and
reduce the life of the cable.
Signal Cable: A cable designed to carry
current of usually less than one
ampere per conductor to operate
signal circuit devices.
Silicone: A material made from silicone
and oxygen. Can be in thermosetting
elastomer or liquid form. The
thermosetting elastomer form is
noted for high heat resistance.
Skin Effect: The tendency of alternating
current to concentrate and to travel
only on the surface of a conductor.
Tendency increases with increase in
frequency.
Sleeving: An extruded tube.
Spark Test: A test designed to locate
imperfections (usually pin-holes) in
the insulation of a wire or cable by
application of voltage for a very short
period of time while the wire is being
drawn through the electrode field.
Specific Gravity: The ratio of the density
(mass per unit volume) of a material
to that of water.
Specific Inductive Capacity (SIC):
Same as dielectric constant. See
Dielectric Constant.

Tank Test: A voltage insulation test in
which the insulated wire or cable is
submerged in water and voltage is
applied between the conductor and
water serving as ground. Shielded
cables are generally not tank tested
due to the possibility of introducing
contaminants on the outer surface of
the insulation.
Teflon : DuPont Company trademark for
fluorocarbon resins. See FEP and
TFE.
®

Temperature Rating: The maximum
temperature at which an insulating
material may be used in continuous
operation without loss of its basic
properties (i.e. operating, overload,
short circuit). The minimum
temperature for safe handling.
Tensile Strength: The pull stress
required to break a given specimen.
Measured in pounds per square inch.
Also referred to as Ultimate Tensile
Strength.
TFE: Tetrafluoroethylene. A thermoplastic
material with good electrical
insulating properties and chemical
and heat resistance.
Thermoplastic: A material that can
be softened repeatedly by heating
and hardened by cooling through a
temperature range characteristic of
the plastic, and that in the softened
state can be shaped by molding or
extrusion.
Thermoset: A material that has been
vulcanized by heat or other means
and is substantially infusible and
insoluble.
Three-Conductor Cable: Three insulated
conductors assembled with other
necessary cable components (shield,
filler, etc.) to form a core, protected
by an overall jacket.
Tinned Copper: Tin coating added to
copper to aid in soldering and inhibit
corrosion.

Tray: A cable tray system is a unit or
assembly of units or sections, and
associated fittings, made of noncombustible materials forming a
rigid structural system used to
support cables. Cable tray systems
(previously termed Continuous Rigid
Cable Supports) include ladders,
troughs, channels, solid bottom trays
and similar structures.
Tray Cable: A factory-assembled multiconductor or multipair control, signal or power cable
specifically approved under the
Canadian Electrical Code for
installation in trays.
Triad: Three insulated wires of a single
circuit forming a unit. (Two or more
units are cabled to form a multi-triad
cable.)
Triplexed Cable: Three individual cables
twisted together without fillers or a
common overall jacket.
UL: Underwriters Laboratories. A nonprofit independent organization,
which operates a listing service for
electrical and electronic materials
and equipment. (Canadian counter­
part is CSA).
UHF: Abbreviation for ultra high
frequency, 300 to 3,000 MHz.
Unilay: A conductor with more than one
layer of helically laid wires with the
direction of lay and length of lay the
same for all layers.
Velocity of Propagation: The speed of
an electrical signal down a length
of cable compared to speed in free
space expressed as a percent. It is
the reciprocal of the square root of
the dielectric constant of the cable
insulation.
VHF: Abbreviation for very high
frequency, 30 to 300 MHz.
Voltage: The term most often used
in place of electromotive force,
potential, potential difference or
voltage drop to designate the electric
pressure that exists between two
points and is capable of producing
a current when a closed circuit is
connected between two points.

Phone: 888-593-3355
www.generalcable.com

SPEC A005
January, 2010

Glossary
Voltage Rating: 1) The highest voltage
that can be continuously applied
to a wire in conformance with the
standard or specification; 2) The
“system” voltage printed on the wire
or cable.
Volume Resistivity: The electrical
resistance between opposite faces of
a one cm. cube of insulating material,
commonly expressed in ohms-meter.
Vulcanization: An irreversible process
during which a compound, through a
change in its chemical structure (e.g.
cross-linking), becomes less plastic
and more resistant to swelling by
organic liquids and elastic properties
are conferred, improved or extended
over a greater range of temperatures.
VW-1: A flammability rating established
by Underwriters Laboratories
for wires and cables that pass a
specially designed vertical flame test,
formerly designated FR-1. Similar to
CSA designation FT1.
Watt: A unit of electric power.
Wicking: The longitudinal flow of a liquid
in a wire or cable due to capillary
action.
Wire: A conductor; bare or insulated.
Yield Strength: The minimum stress
at which a material will start to
physically deform without further
increase in load.

Phone: 888-593-3355
www.generalcable.com

SPEC A025

January, 2010

Reference Standards
AAR S-501: Specification for Wire and
Cables

ASTM B 3: Standard Specification for
Soft or Annealed Copper Wire

AAR 581.3: Specification for Single
Conductor, Clean Stripping Rubber
Insulated, 0–600 Volts, Neoprene
Jacketed Cable for Locomotive and Car
Equipment

ASTM B 8: Standard Specification
for Concentric-Lay Stranded Copper
Conductors, Hard, Medium-Hard or Soft

AAR 589: Specification for Single
Conductor Chloro­sulfonated Polyethylene
Integral Insulated-Jacketed, 0-300 V,
0-600 V Cable for Locomotive and Car
Equipment
AEIC CS 1: Specifications for Solid-Type
Impregnated-Paper-Insulated Metallic
Sheathed Cable
AEIC CS2: Specifications for
Impregnated-Paper and Laminated
Paper-Polypropylene Insulated Cable,
High-Pressure Pipe-Type
AEIC CS3: Specifications for
Impregnated-Paper-Insulated, Metallic
Sheathed Cable, Low Pressure Gas-Filled
Type
AEIC CS4: Specifications for
Impregnated-Paper-Insulated Low and
Medium Pressure Self Contained Liquid
Filled Cable
*AEIC CS5: Specifications for
Thermoplastic and Crosslinked
Polyethylene Insulated Shielded Power
Cables Rated 5 Through 69 kV

ASTM B 33: Standard Specification for
Tinned Soft or Annealed Copper Wire for
Electrical Purposes
ASTM B 105: Standard Specification
for Hard-Drawn Copper Alloy Wires for
Electrical Conductors

ASTM B 172: Standard Specification for
Rope-Lay-Stranded Copper Conductors
Having Bunch-Stranded Members, for
Electrical Conductors

ASTM B 246: Standard Specification
for Tinned Hard-Drawn and MediumHard-Drawn Copper Wire for Electrical
Purposes

ASTM B 173: Standard Specification for
Rope-Lay-Stranded Copper Conductors
Having Concentric-Stranded Members, for
Electrical Conductors

ASTM B 258: Standard Specification
for Standard Nominal Diameters and
Cross-Sectional Areas of AWG Sizes of
Solid Round Wires Used as Electrical
Conductors

ASTM B 174: Standard Specification for
Bunch-Stranded Copper Conductors for
Electrical Conductors
ASTM B 189: Standard Specification for
Lead-Coated and Lead-Alloy-Coated Soft
Copper Wire for Electrical Purposes
ASTM B 193: Standard Test Method
for Resistivity of Electrical Conductor
Materials

AEIC CS7: Specifications for Crosslinked
Poly­ethylene Insulated Shielded Power
Cables Rated 46 Through 138 kV

ASTM B 227: Standard Specification for
Hard-Drawn Copper-Clad Steel Wire

ANSI MC96.1: Thermocouple Extension
Wire Calibration
ANSI N45.2: Packaging, Shipping,
Receiving, Storage and Handling of Items
for Nuclear Power Plants
ASTM B 1: Standard Specification for
Hard-Drawn Copper Wire
ASTM B 2: Standard Specification for
Medium-Hard-Drawn Copper Wire

ASTM B 232M: Standard Specification
for Concentric-Lay-Stranded Alumi­num
Conductors, Coated Steel-Reinforced
(ACSR) [Metric]
ASTM B 233: Standard Specification
for Aluminum 1350 Drawing Stock for
Electrical Purposes

ASTM B 226: Standard Specification for
Cored, Annular, Concentric-Lay-Stranded
Copper Conductors

ANSI C2: National Electrical Safety Code

ASTM B 232: Standard Specification
for Concentric-Lay-Stranded Aluminum
Conductors, Coated Steel-Reinforced
(ACACARSR)

ASTM B 170: Standard Specification for
Oxygen-Free Electrolytic Copper

*AEIC CS6: Specifications for Ethylene
Propylene Rubber Insulated Shielded
Power Cables Rated 5 Through 69 kV

AEIC CS8: Specification for Extended
Dielectric, Shielded Power Cables Rated
5 through 46 kV

ASTM B 231 M: Standard Specification
for Concentric-Lay-Stranded Aluminum
1350 Conductors [Metric]

ASTM B 228: Standard Specification for
Concentric-Lay-Stranded Copper-Clad
Steel Conductors
ASTM B 229: Standard Specification for
Concentric-Lay-Stranded Copper and
Copper-Clad Steel Composite Conductors
ASTM B 230: Standard Specification for
Aluminum 1350-H19 Wire for Electrical
Purposes
ASTM B 230M: Standard Specification
for Aluminum 1350-H19 Wire for Electrical
Purposes [Metric]

ASTM B 263: Standard Test Method for
Determination of Cross-Sectional Area of
Stranded Conductors
ASTM B 286: Standard Specification for
Copper Conductors for Use in Hookup
Wire for Electronic Equipment
ASTM B 298: Standard Specification for
Silver-Coated Soft or Annealed Copper
Wire
ASTM B 324: Standard Specification for
Nickel-Coated Soft or Annealed Copper
Wire
ASTM B 341: Standard Specification for
Aluminum-Coated (Aluminized) Steel Core
Wire for Aluminum Conductors, SteelReinforced (ACSR/AZ)
ASTM B 341M: Standard Specification
for Aluminum-Coated (Aluminized) Steel
Core Wire for Aluminum Conductors,
Steel-Reinforced (ACSR/AZ) [Metric]
ASTM B 355: Standard Specification for
Nickel-Coated Soft or Annealed Copper
Wire
ASTM B 397: Standard Specification for
Concentric-Lay-Stranded Aluminum-Alloy
5005-H19 Conductors

ASTM B 231: Standard Specification for
Concentric-Lay-Stranded Aluminum 1350
Conductors

* These standards or specifications have been rescinded by their organizations.
Phone: 888-593-3355
www.generalcable.com

SPEC A025

January, 2010

Reference Standards
ASTM B 398: Standard Specification
for Aluminum-Alloy 6201-T81 Wire for
Electrical Purposes
ASTM B 398M: Standard Specification
for Aluminum-Alloy 6201-T81 Wire for
Electrical Purposes [Metric]
ASTM B 399: Standard Specification for
Concentric-Lay-Stranded Aluminum-Alloy
6201-T81 Conductors
ASTM B 399M: Standard Specification
for Concentric-Lay-Stranded AluminumAlloy 6201-T81 Conductors [Metric]
ASTM B 400: Standard Specification
for Compact Round Concentric-LayStranded Aluminum 1350 Conductors
ASTM B 401: Standard Specification
for Compact Round Concentric-LayStranded Aluminum Conductors, SteelReinforced (ACSR/COMP)
ASTM B 416: Standard Specification for
Concentric-Lay-Stranded Aluminum-Clad
Steel Conductors
ASTM B 452: Standard Specification for
Copper-Clad Steel Wire for Electronic
Application
ASTM B 470: Standard Specification for
Bonded Copper Conductors for Use in
Hookup Wires for Electronic Equipment
ASTM B 496: Standard Specification
for Compact Round Concentric-LayStranded Copper Conductors
ASTM B 498: Standard Specification
for Zinc-Coated (Galvanized) Steel Core
Wire for Aluminum Conductors, SteelReinforced (ACSR)
ASTM B 498M: Standard Specification
for Zinc-Coated (Galvanized) Steel Core
Wire for Aluminum Conductors, SteelReinforced (ACSR) [Metric]
ASTM B 500: Standard Specification
for Zinc-Coated (Galvanized), Zinc-5%
Aluminum Mischmetal Alloy-Coated, and
Aluminum-Coated (Aluminized) Stranded
Steel Core for Aluminum Conductors,
Steel-Reinforced (ACSR)
ASTM B 501: Standard Specification for
Silver-Coated, Copper-Clad Steel Wire for
Electronic Application

Phone: 888-593-3355
www.generalcable.com

ASTM B 502: Standard Specification
for Aluminum-Clad Steel Core Wire for
Aluminum Conductors, Aluminum-Clad
Steel Reinforced

ASTM B 738: Standard Specification for
Fine-Wire Bunch-Stranded and Rope-Lay
Bunch Stranded Copper Conductors for
Use as Electrical Conductors

ASTM B 520: Standard Specification for
Tin-Coated, Copper-Clad Steel Wire for
Electronic Application

ASTM B 778: Standard Specification for
Shaped Wire Compact Concentric-LayStranded Aluminum Conductors (AAC/
TW)

ASTM B 524: Standard Specification
for Concentric-Lay-Stranded Aluminum
Conductors, Aluminum-Alloy Reinforced
(ACAR, 1350/6201)
ASTM B 524M: Standard Specification
for Concentric-Lay-Stranded Aluminum
Conductors, Aluminum-Alloy Reinforced
(ACAR, 1350/6201) [Metric]
ASTM B 549: Standard Specification
for Concentric-Lay-Stranded Aluminum
Conductors, Aluminum-Clad Steel
Reinforced (ACSR/AW)
ASTM B 559: Standard Specification for
Nickel-Coated, Copper-Clad Steel Wire
for Electronic Application
ASTM B 606: Standard Specification for
High-Strength Zinc-Coated (Galvanized)
Steel Core Wire for Aluminum and
Aluminum Alloy Conductors, Steel
Reinforced
ASTM B 609: Standard Specification for
Aluminum 1350 Round Wire, Annealed
and Intermediate Tempers, for Electrical
Purposes
ASTM B 609M: Standard Specification
for Aluminum 1350 Round Wire, Annealed
and Intermediate Tempers, for Electrical
Purposes [Metric]
ASTM B 624: Standard Specification for
High-Strength, High-Conductivity CopperAlloy Wire for Electronic Application
ASTM B 682: Standard Specification
for Standard Metric Sizes of Electrical
Conductors

ASTM B 779: Standard Specification for
Shaped Wire Compact Concentric-LayStranded Aluminum Conductors, Steel
Reinforced (ACSR/TW)
ASTM B 784: Standard Specification
for Modified Concentric-Lay-Stranded
Copper Conductors for Use in Insulated
Electrical Cables
ASTM B 785: Standard Specification for
Compact Round Modified ConcentricLay-Stranded Copper Conductors for Use
in Insulated Electrical Cables
ASTM B 786: Standard Specification
for 19 Wire Combination UnilayStranded Aluminum 1350 Conductors for
Subsequent Insulation
ASTM B 787: Standard Specification for
19 Wire Combination Unilay-Stranded
Copper Conductors for Subsequent
Insulation
ASTM B 801: Standard Specification for
Concentric-Lay-Stranded Conductors
of 8000 Series Aluminum Alloy for
Subsequent Covering or Insulation
ASTM B 802: Standard Specification for
Zinc-5% Aluminum-Mischmetal AlloyCoated Steel Core Wire for Aluminum
Conductors, Steel Reinforced (ACSR)
ASTM B 803: Standard Specification
for High-Strength Zinc-5 % AluminumMischmetal Alloy Coated Steel Core
Wire for Aluminum and Aluminum-Alloy
Conductors, Steel Reinforced

ASTM B 701: Standard Specification for
Concentric-Lay-Stranded Self-Damping
Aluminum Conductors, Steel-Reinforced
(ACSR/SD)

ASTM D 149: Standard Test Method
for Dielectric Break­down Voltage and
Dielectric Strength of Solid Electrical
Insulating Materials at Commercial Power
Frequencies

ASTM B 711: Standard Specification for
Concentric-Lay-Stranded Aluminum-Alloy
Con­ductors, Steel Reinforced (AACSR)
(6201)

ASTM D 470: Method of Testing
Crosslinked Insula­tions and Jackets for
Wire and Cable
ASTM D 866: Specification for StyreneButadiene (SBR) Synthetic Rubber Jacket
for Wire and Cable

SPEC A025

January, 2010

Reference Standards
ASTM D 1047: Specification for Polyvinyl
Chloride (PVC) Jacket for Wire and Cable
ASTM D 1351: Specification for
Polyethylene Insulation for Wire and Cable
ASTM D 1352: Specification for OzoneResisting Butyl Rubber Insulation for Wire
and Cable
ASTM D 1523: Method for Synthetic
Rubber Insulation for Wire and Cable, 90°
Operation
ASTM D 1679: Specification for Synthetic
Rubber Heat and Moisture-Resisting
Insulation for Wire and Cable, 75°C
Operation
ASTM D 2219: Specification for Polyvinyl
Chloride (PVC) Insulation for Wire and
Cable, 60° Operation
ASTM D 2220: Specification for Polyvinyl
Chloride (PVC) Insulation for Wire and
Cable, 75° Operation
ASTM D 2308: Specification for
Polyethylene Jacket for Electrical Insulated
Wire and Cable
ASTM D 2526: Specification for OzoneResisting Silicone Rubber Insulation for
Wire and Cable
ASTM D 2655: Specification for
Crosslinked Polyethylene Insulation for
Wire and Cable Rated 0 to 2000 V
ASTM D 2656: Specification for
Crosslinked Polyethylene Insulation for
Wire and Cable Rated 2001 to 35000 V
ASTM D 2768: Specification for GeneralPurpose Ethylene-Propylene Rubber
Jacket for Wire and Cable
ASTM D 2770: Specification for OzoneResisting Ethylene-Propylene Rubber
Integral Insulation and Jacket for Wire and
Cable
ASTM D 2802: Specification for OzoneResistant Ethylene-Propylene Rubber
Insulation for Wire and Cable
ASTM D 3004: Specification for Extruded
Thermo­set­ting and Thermoplastic SemiConduct­ing Conductor and Insulation
Shields
ASTM D 3485: Specification for SmoothWall Coilable Polyethylene (PE) Conduit
(Duct) for Preassembled Wire and Cable

ASTM D 3554: Specification for TrackResistant Black Thermoplastic High
Density Poly­ethylene Insulation for Wire
and Cable
ASTM D 3555: Specification for TrackResistant Black Crosslinked Thermosetting
Poly­ethylene Insulation for Wire and Cable
ASTM D 4244: Specification for GeneralPurpose, Heavy-Duty and Extra-Heavy
Duty Acrylonitrile-Butadiene/ Polyvinyl
Chloride (NBR/PVC) Jackets for Wire and
Cable
ASTM D 4245: Specification for OzoneResistant Thermoplastic Elastomer
Insulation for Wire and Cable, 90°C Dry 75°C Wet Operation
ASTM D 4246: Specification for OzoneResistant Thermoplastic Elastomer
Insulation for Wire and Cable, 90°C
Operation
ASTM D 4247: Specification for GeneralPurpose Black Heavy-Duty and Black
Extra-Heavy Duty Polychloroprene
Jackets for Wire and Cable
ASTM D 4313: Specification for General
Purpose Heavy-Duty and Extra-HeavyDuty Crosslinked Chlorinated Poly­
ethylene Jackets for Wire and Cable
ASTM D 4314: Specification for General
Purpose Heavy-Duty and Extra-HeavyDuty Crosslinked Chlorosulfonated Poly­
ethylene Jackets for Wire and Cable
ASTM D 4363: Specification for
Thermoplastic Chlorinated Polyethylene
Jacket for Wire and Cable
ASTM D 4496: Test Method of DC
Resistance or Conductance of Moderately
Conductive Materials
ASTM D 4568: Test Methods for
Evaluating Compatibility Between Cable
Filling and Flooding Compounds and
Polyolefin Cable Materials
ASTM D 4967: Guide for Selecting
Materials to Be Used for Insulation,
Jacketing, and Strength Components in
Fiber Optic Cables
CAN3-Z299.0: Guide for Selecting and
Implement­ing the CAN3-Z299 Quality
Assurance Program Standards
CAN3-Z299.1: Standard for Quality
Assurance Program - Category 1

CAN3-Z299.2: Standard for Quality
Assurance Program - Category 2
CAN3-Z299.3: Standard for Quality
Assurance Program - Category 3
CAN3-Z299.4: Standard for Quality
Assurance Program - Category 4
CAN/CSA C22.2 No. 211: Standard for
Cord Sets and Power-Supply Cords
CAN/CSA C22.2 No. 48: Standard for
Nonmetallic Sheathed Cable
CAN/CSA C22.2 No. 49: Standard for
Flexible Cords and Cables
CAN/CSA C22.2 No. 51: Standard for
Armored Cable
CAN/CSA C22.2 No. 96: Standard for
Portable Power Cables
CAN/CSA C22.2 No. 130.1: Standard for
Heat-Tracing Cable Systems for Use in
Industrial Locations
CAN/CSA C22.2 No. 131: Standard for
Type TECK 90 Cable
CAN/CSA C22.2 No. 203: Standard
for Modular Wiring Systems for Office
Furniture
CAN/CSA C22.2 No. 210.2: Standard for
Appliance Wiring Material Products
CAN/CSA C22.2 No. 214: Standard for
Communications Cables
CAN/CSA C22.2 No. 233: Standard for
Cords and Cord Sets for Communication
Systems
CAN/CSA C22.2 No. 239: Standard for
Control and Instrumentation Cables
CAN/CSA C22.2 No. 241: IEEE Standard
for Cable Joints for Use with Extruded
Dielectric Cable Rated 5,000V Through
46,000V, and Cable Joints for Use with
Laminated Dielectric Cable Rated 2,500 V
Through 500,000 V (Adopted IEEE 4041986)
CAN/CSA C22.3 No. 1: Standard for
Overhead Systems
CAN/CSA C22.3 No. 8: Standard for
Railway Electrifi­ca­tion Guidelines
CAN/CSA C49.1: Standard for Round
Wire, Concentric Lay, Overhead Electrical
Conductors

Phone: 888-593-3355
www.generalcable.com

SPEC A025

January, 2010

Reference Standards
CAN/CSA C68.3: Standard for Shielded
and Concentric Neutral Power Cables
Rated 5-46 kV
CAN/CSA T529: Standard Design Guide
for Tele­communi­cations Wiring Systems
in Commercial Buildings
CSA C22.1: Canadian Electrical Code,
Part 1, Safety Standard for Electrical
Installations

CSA C22.2 No. 198.2: Standard for
Underground Cable Splicing Kits
CSA C22.2 No. 208: Standard for Fire
Alarm and Signal Cable
CSA C22.2 No. 222: Standard for Type
FCC Under-Carpet Wiring System
CSA C22.2 No. 230: Standard for Tray
Cable

CSA C22.2 No. 0.3: Standard for Test
Methods for Electrical Wires and Cables

CSA C22.2 No. 232: Standard for Optical
Fiber Cables

CSA C22.2 No. 16: Standard for
Insulated Conductors for Power-Operated
Electronic Devices

CSA/CAN3 C22.3 No. 7: Standard for
Underground Systems

CSA C22.2 No. 35: Standard for ExtraLow-Voltage Control Circuit Cables, LowEnergy Control Cable, and Extra-LowVoltage Control Cable
CSA C22.2 No. 38: Standard for
Thermoset Insulated Wires and Cables
CSA C22.2 No. 52: Standard for ServiceEntrance Cables
CSA C22.2 No. 75: Standard for
Thermoplastic-Insulated Wires and
Cables
CSA C22.2 No. 116: Standard for CoilLead Wires
CSA C22.2 No. 123: Standard for
Aluminum Sheathed Cables
CSA C22.2 No. 124: Standard for
Mineral-Insulated Cable
CSA C22.2 No. 127: Standard for
Equipment Wires
CSA C22.2 No. 129: Standard for Neutral
Supported Cable
CSA C22.2 No. 130: Standard for
Heating Cables and Heating Cable Sets
CSA C22.2 No. 138: Standard for Heat
Tracing Cable and Cable Sets for Use in
Hazardous Locations
CSA C22.2 No. 174: Standard for Cables
and Cable Glands for Use in Hazardous
Locations
CSA C22.2 No. 179: Standard for Airport
Series Lighting Cables
CSA C22.2 No. 188: Standard for
Splicing Wire and Cable Connectors

Phone: 888-593-3355
www.generalcable.com

CSA C49.2: Standard for Compact
Aluminum Conductors Steel Reinforced
(ACSR)

EIA/TIA-606: Administration Standard for
the Tele­com­mu­ni­cations Infrastructure of
Commercial Buildings
EIA/TIA TSB-36: Additional Cable
Specifications for Un­shielded Twisted Pair
Cables (Technical Systems Bulletin 36)
EIA/TIA TSB-40: Additional Transmission
Specifications for Unshielded Twisted Pair
Connecting Hardware (Technical Systems
Bulletin 40)
FP-4: TM-4 CSA CBC and UL CMR
(Riser) Cable
FP-16: TD-16 Plastic Insulated, Two
Parallel Conductor, Telephone Drop Wire
FP-28: Air Core, Solid PIC, ALPETHDCAS Cable and PAP-DCAS Cable

CSA C49.3: Standard for Aluminum
Alloy 1350 Round Wire, All Tempers, for
Electrical Purposes

FP-67: PHD Plastic Insulated and
Jacketed, Four Conductor, Telephone
Drop Wire

CSA C49.4: Standard for Concentric-Lay
Alumi­num Stranded Conductors (ASC)

FP-68: TM-68 CSA PCC FT4, Shielded
Inside Wiring Cable

CSA C49.5: Standard for Compact Round
Concentric-Lay Aluminum Stranded
Conductors (Compact ASC)

FP-71: TM-28 CSA PCC FT4, Inside
Wiring Cable

CSA CAN3-C49.6: Standard for ZincCoated Steel Wires for Use in Overhead
Electrical Conductors
CSA CAN3-C49.7: Standard for
Aluminum Round Wires for Use in
Overhead Electrical Conductors
CSA C68.1: Standard Specifications for
Impreg­nated Paper-Insulated, MetallicSheathed Cable, Solid-Type
CSA C170.2: Standard for Polyethylene
Protective Covering on Paper-Insulated
Metallic Sheathed Power Cable
CSA C170.3: Standard for PolyvinylChloride (PVC) Protective Covering on
Paper-Insulated Metallic-Sheathed Power
Cable
CSA M421: Standard for Use of
Electricity in Mines
EIA/TIA-568: Commercial Building
Telecom­muni­ca­tions Wiring Standard
EIA/TIA-569: Commercial Building
Standard for Telecom­munications
Pathways and Spaces

FP-75: PHILPLAST CSA PCC FT4, PVC
Insulated and Jacketed, Switchboard
Cable
FP-81: TM-81 CSA ZSW FT1, Telephone
Station Wire
FP-90: CONCEL Cellular Polyethylene
Insulated, Air Core, ALPETH-DCAS
Sheathed, Telephone Cable
FP-93: TM-91, TM-92, TM-93 and TM-97,
Filled, Buried Wire
FP-95: Quasi-Solid Polyethylene
Insulated, Filled, Regular and Twin Core,
ALPETH-DCAS Sheathed Cable
FP-98: CELSEAL Cellular Polyethylene
Insulated, Filled, ALPETH-DCAS
Sheathed Cable
FP-99: DUCTCEL Cellular Polyethylene
Insulated, Air Core, ALPETH-DCAS
Sheathed Telephone Cable
FP-8859: PHILSYM UL 444 CMR and
CSA PCC FT4 Switchboard Cable
HP: See NEMA listing
ICEA P-32-382: ICEA Standards
Publication for Short Circuit
Characteristics of Insulated Cable

SPEC A025

January, 2010

Reference Standards
ICEA P-45-482: ICEA Standards
Publication for Short-Circuit Performance
of Metallic Shields and Sheaths of
Insulated Cable
ICEA P-53-426: ICEA/NEMA Standards
Publication for Ampacities, Including
Effect of Shield Losses for SingleConductor Solid-Dielectric Power Cable
15 kV through 69 kV (NEMA WC50)
ICEA P-54-440: ICEA/NEMA Standards
Publication for Ampacities of Cables in
Open-Top Cable Trays (NEMA WC51)

ICEA S-83-596: ICEA/ANSI Standards
Publication for Fiber Optic Premises
Distribution Cable

ANSI/ICEA T-28-562: ICEA Standard
Test Method for Measurement of Hot
Creep of Polymeric Insulations

ICEA S-84-608: ICEA/ANSI Standards
Publication for Telecommunications
Cable, Filled Polyolefin Insulated, Copper
Conductor

ICEA T-29-520: ICEA Standard for
Vertical Tray Flame Tests at 210,000 Btu

ICEA S-85-625: ICEA/ANSI Standards
Publication for Aircore, Polyolefin
Insulated, Copper Conductor
Telecommuni­cations Cable

ICEA P-79-561: ICEA Guide for Selecting
Aerial Cable Messengers and Lashing
Wires

ICEA S-86-634: ICEA/ANSI Standards
Publication for Buried Distribution and
Service Wire, Filled Polyolefin Insulated,
Copper Conductor

ICEA S-56-434: ICEA/ANSI Standards
Publication for Poly­olefin Insulated
Communica­tions Cables for Outdoor Use

ICEA S-87-640: ICEA/ANSI Standards
Publication for Fiber Optic Outside Plant
Communication Cable

ICEA S-67-401: ICEA/NEMA Standards
Publication for Steel Armor and
Associated Coverings for ImpregnatedPaper-Insulated Cables (NEMA WC2)

ICEA-S-93-639: ICEA/NEMA Standard for
Shielded Power Cables Rated 5-46 kV for
the Distribution of Electrical Energy (NEMA
WC74)

ANSI/ICEA S-70-547: ICEA/ANSI
Standards Publication for WeatherResistant Polyolefin-Covered Wire
and Cable

ANSI/ICEA-S-94-649: Standard for
Concentric Neutral Cables Rated 5-46 kV

ICEA T-30-520: ICEA Standard for
Vertical Tray Flame Tests at 70,000 Btu
ICEA T-31-610: ICEA Standard for Water
Penetration Resistance Test, Sealed
Conductor
ICEA T-32-645: ICEA Standards
Publication for Compatibility of Sealed
Conductor Filer Compounds
IEC 92-3: International Electrotechnical
Commission Electrical Installation in Ships
- Part 3 Cables (Constructions, Testing
and Installations)
IEEE 45: IEEE Recommended Practice
for Electric Installations on Shipboard
IEEE 48: IEEE Standard Test Procedures
and Requirements for High-Voltage Alter­­
nating Current Cable Terminations
IEEE 100: IEEE Standard Dictionary of
Electrical and Electronics Terms

ICEA S-73-532: ICEA/NEMA/ANSI Standards
Publi­ca­tion for Control Cables (NEMA WC57)

ICEA S-95-658: ICEA/NEMA Standard
for Non-shielded Power Cables Rated
2000 Volts or Less for the Distribution of
Electrical Energy (NEMA WC70)

ICEA S-75-381: ICEA/NEMA/ANSI
Standards Publication for Portable and
Power Feeder Cables for Use in Mines and
Similar Applications (NEMA WC58)

ICEA S-96-659: ICEA/NEMA Standard
for Non-shielded Cables Rated 2001-5000
Volts for use in the Distribution of Electrical
Energy (NEMA WC71)

IEEE 142: IEEE Recommended
Practice for Grounding of Industrial and
Commercial Power Systems (“IEEE
Green Book”)

ANSI/ICEA S-76-474: ICEA/ANSI
Standards Publication for NeutralSupported Power Cable Assemblies with
Weather-Resistant Extruded Insulation,
600 Volts

ANSI/ICEA S-97-682: Standard for Utility
Shielded Power Cable Rated 5-46 kV

IEEE 241: IEEE Recommended Practice
for Electric Power Systems in Com­mercial
Buildings (“IEEE Gray Book”)

ICEA S-77-528: ICEA/ANSI Standards
Publication for Outside Plant
Communications Cables, Specifying
Metric Wire Sizes
ICEA S-80-576: ICEA/ANSI Standards
Publication for Communications Wire and
Cable for Wiring of Premises
ANSI/ICEA S-81-570: Standard for 600
volt rated cables of Ruggedized Design
For Direct Burial installations of single
conductors or assemblies of single
conductors.
ICEA S-82-552: ICEA/NEMA Standards
Publication for Instru­mentation Cables and
Thermocouple Wire (NEMA WC55)

ANSI/ICEA S-105-692: Standard for 600
Volt Single Layer Thermoset Insulated
Utility Underground Distribution Cable
ICEA T-22-294: ICEA Standard Test
Procedures for Extended Time-Testing of
Wire and Cable Insulations for Service in
Wet Locations
ICEA T-25-425: ICEA Guide for
Establishing Stability of Volume Resistivity
for Conducting Polymeric Components of
Power Cables
ICEA T-26-465: ICEA/NEMA Guide for
Frequency of Sampling Extruded Dielectric
Power, Control, Instru­mentation and Port­
able Cables for Test (NEMA WC54)

IEEE 141: IEEE Recommended Practice
for Electric Power Distribution for
Industrial Plants (“IEEE Red Book”)

IEEE 242: IEEE Recommended Practice
for Protection and Coordination of
Industrial and Commercial Power
Systems (“IEEE Buff Book”)
IEEE 323: IEEE Standard for Qualifying
Class 1E Equipment for Nuclear Power
Generating Stations
IEEE 383: IEEE Standard for Type Test
of Class 1E Electric Cables, Field Splices
and Connections for Nuclear Power
Generating Stations

ICEA T-27-581: ICEA/NEMA Standard
Test Methods for Extruded Dielectric
Power, Control, Instrumentation and
Portable Cables (NEMA WC53)
Phone: 888-593-3355
www.generalcable.com

SPEC A025

January, 2010

Reference Standards
IEEE 400: IEEE Guide for Making HighDirect-Voltage Tests on Power Cable
Systems in the Field
IEEE 404: IEEE Standard for Cable Joints
for Use with Extruded Dielectric Cable
Rated 5,000 V Through 46,000 V, and
Cable Joints for Use with Laminated
Dielectric Cable Rated 2,500 V Through
500,000 V (Adopted as a National
Standard of Canada, CAN/CSA-C22.2
No. 241)
IEEE 446: IEEE Recommended Practice
for Emergency and Standby Power
Systems for Industrial and Commercial
Applications (“IEEE Orange Book”)
IEEE 493: IEEE Recommended Practice
for the Design of Reliable Industrial and
Commercial Power Systems (“IEEE Gold
Book”)
IEEE 515: IEEE Recommended Practice
for the Testing, Design, Installation, and
Maintenance of Electrical Resistance Heat
Tracing for Industrial Applications
IEEE 524: IEEE Guide to the Installation of
Over­head Transmission Line Conductors
IEEE 525: IEEE Guide for the Design
and Install­ation of Cable Systems in
Substations
IEEE 575: IEEE Guide for the Application
of Sheath-Bonding Methods for SingleConductor Cables and the Calcula­tion of
Induced Voltages and Currents in Cable
Sheaths
IEEE 576: IEEE Recommended Practice
for Installation, Termination, and Testing
of Insulated Power Cable as Used in the
Petroleum and Chemical Industry

IEEE 789: IEEE Standard Performance
Requirements for Communications and
Control Cables for Application in High
Voltage Environments
IEEE 802.3: IEEE Standard for
Information Processing Systems - Local
and Metropolitan Area Networks - Part
3: Carrier Sense Multiple Access with
Collision Detection (CSMA/CD) Access
Method and Physical Layer Specifications
(ISO/IEC) (ANSI/IEEE Std 802.3)
IEEE 802.5: IEEE Standard for
Information Technology - Local and
Metropolitan Area Networks - Part 5:
Token Ring Access Method and Physical
Layer Specifications (ISO/IEC) (ANSI/IEEE
Std 802.5)
IEEE 816: IEEE Guide for Determining
the Smoke Generation of Solid Materials
Used for Insulations and Coverings of
Electric Wire and Cable
IEEE 844: IEEE Recommended Practice
for Electrical Impedance, Induction, and
Skin Effect Heating of Pipelines and
Vessels

Mil-C-85045: General Specification for
Fiber Optic Cables [Metric]
Mil-W-16878: General Specification for
Insulated Electrical Wire
Mil-W-22759: General Specification for
Copper or Copper Alloy FluoropolymerInsulated Electrical Wire
Mil-W-81044: General Specification for
Copper or Copper Alloy, Crosslinked
Polyalkene, Crosslinked Alkane-Imide
Polymer or Polyalkene Insulated Electrical
Wire
Mil-W-81381: General Specification for
Replacement Wire

IEEE 1018: IEEE Recommended Practice
for Specifying Electric Submersible Pump
Cable – Ethylene-Propylene Rubber
Insulation

NAVSEA 6710782: Fiber Optic and
Multimode Cable

IEEE 1019: IEEE Recommended Practice
for Specifying Electric Submersible Pump
Cable – Polypropylene Insulation

IEEE 602: IEEE Recommended Practice
for Electric Systems in Health Care
Facilities (“IEEE White Book”)

IEEE 1202: IEEE Standard for Flame
Testing of Cables for Use in Cable Tray in
Indus­trial and Commercial Occupancies

IEEE 635: IEEE Guide for Selection and
Design of Aluminum Sheaths for Power
Cables

IEEE/ICEA S-135: Power Cable
Ampacities

Phone: 888-593-3355
www.generalcable.com

Mil-C-27500: General Specification for
Shielded and Unshielded Electrical Power
Cable and Special Purpose Cable

Mil-W-85485: General Specification for
Radio Frequency Absorptive Filter Line
Electrical Cable

IEEE 590: IEEE Cable Plowing Guide

IEEE 738: IEEE Standard for Calculation
of Bare Overhead Conductor Temperature
and Ampacity Under Steady-State
Conditions

Mil-C-24643: General Specification
for Low Smoke Electrical Cable and
Conductors for Shipboard Use

IEEE 1017: IEEE Recommended Practice
for Field Testing Electric Submersible
Pump Cable

IEEE 1120: IEEE Guide to the Factors to
Be Considered in the Planning, Design,
and Installation of Submarine Power and
Communications Cables

IEEE 644: IEEE Standard Procedures for
Measurement of Power Frequency Electric
and Magnetic Fields from AC Power Lines

Mil-C-24640: General Specification for
Lightweight Electrical Cable for Shipboard
Use

Mil-C-17: General Specifications for
Flexible and Semirigid Radio Frequency
Cables
Mil-C-915F: General Specification for
Electrical Cable and Conductors for
Shipboard Use
Mil-C-13777: General Specification for
Special Purpose Electrical Cable

NEMA HP 3: Electrical and Electronic
PTFE (Polytetra­fluoro-ethylene) Insulated
High Temperature Hook-Up Wire; Types
(600 Volt), EE (1000 Volt), and ET (250 Volt)
NEMA HP 4: Electrical and Electronic FEP
Insulated High Temperature Hook-Up Wire;
Types K, KK, and KT
NEMA HP 100: High Temperature
Instrumentation and Control Cables
NEMA HP 100.1: High Temperature
Instrumentation and Control Cables
Insulated and Jacketed with FEP
Fluorocarbons
NEMA HP 100.2: High Temperature
Instrumentation and Control Cables
Insulated and Jacketed with ETFE
Fluoropolymers
NEMA HP 100.3: High Temperature
Instrumentation and Control Cables
Insulated and Jacketed with Cross-Linked
(Thermoset) Polyolefin (XLPO)

SPEC A025

January, 2010

Reference Standards
NEMA HP 100.4: High Temperature
Instrumentation and Control Cables
Insulated and Jacketed with ECTFE
Fluoropolymers

NEMA WC61: Transfer Impedance Testing

NEMA WC2: Steel Armor and Associated
Coverings for Impregnated-PaperInsulated Cables (ICEA S-67-401)

NEMA WC70: Standard for Non-shielded
Power Cables Rated 2000 Volts or Less for
the Distribution of Electrical Energy
(ICEA S-95-658)

NEMA WC3: Rubber-Insulated Wire
and Cable for the Transmission and
Distribution of Electrical Energy
(ICEA S-19-81)
NEMA WC5: Thermoplastic-Insulated
Wire and Cable for the Transmission and
Distribution of Electrical Energy
(ICEA S-61-402)
NEMA WC7: Cross-LinkedThermosetting-Polyethylene-Insulated
Wire and Cable for the Transmission and
Distribution of Electrical Energy
(ICEA S-66-524)
NEMA WC8: Ethylene-PropyleneRubber-Insulated Wire and Cable for the
Transmission and Distribution of Electrical
Energy (ICEA S-68-516)

NEMA WC62: Repeated Spark/Impulse
Dielectric Testing

NEMA WC71: Standard for Non-shielded
Cables Rated 2001-5000 Volts for Use in
the Distribution of Electrical Energy
(ICEA S-96-659)
NEMA WC74: Standard for Shielded
Power Cables Rated 5-46 kV for the
Distribution of Electrical Energy
(ICEA S-93-639)
NFPA 70: National Electrical Code
NFPA 70HB: National Electrical Code
Handbook
NFPA 262: Test for Fire and Smoke
Characteristics of Wires and Cables
ONT M-302-84: Cable, Secondary, for
Direct Burial

NEMA WC26: Wire and Cable Packaging

ONT M-355-82: Cable, Primary Submarine

NEMA WC50: Ampacities, Including
Effect of Shield Losses for SingleConductor Solid Dielectric Power Cable
15 kV through 69 kV (ICEA P-53-426)

ONT M-538-84: Cable, For Use in
Generating Stations (5 kV and Above)

NEMA WC51: Ampacities of Cables in
Open-Top Cable Trays (ICEA P-54-440)
NEMA WC52: High Temperature and
Electronic Insulated Wire-Impulse
Dielectric Testing
NEMA WC53: Standard Test Methods
for Extruded Dielectric Power, Control,
Instru­menta­tion, and Portable Cables
(ICEA T-27-581)
NEMA WC54: Guide for Frequency of
Sampling Extruded Dielectric Power,
Control, Instrumentation, and Portable
Cables for Test (ICEA T26-465)
NEMA WC55: Instrumentation Cables
and Thermocouple Wire (ICEA S-82-552)
NEMA WC56: 3.0 kHz Insulation
Continuity Proof Testing of Hook-Up Wire
NEMA WC57: Standard for Control Cables
(ICEA S-73-532)
NEMA WC58: Standard for Portable and
Power Feeder Cables for Use in Mines and
Similar Applications (ICEA-S-75-381)

ONT M-570-84: Cable, For Use in
Generating Stations (600 V)
ONT M-695-88: Cable, Primary and
Subtransmission Submarine, Concentric
Neutral
SAE 1560: Low Tension, Thin Wall Primary
Cable
SAE J1127: Battery Cable
SAE J1128: Low Tension Primary Cable
TIA: See EIA/TIA
UL 4: Standard for Armored Cable
UL 13: Standard for Power-Limited Circuit
Cables
UL 44: Standard for Rubber-Insulated
Wires and Cables
UL 62: Standard for Flexible Cord and
Fixture Wire
UL 83: Standard for ThermoplasticInsulated Wires and Cables

UL 444: Standard for Communications
Cables
UL 486A: Standard for Wire Connectors
and Soldering Lugs for Use With Copper
Conductors
UL 486B: Standard for Wire Connectors
and Soldering Lugs for Use With Aluminum
Conductors
UL 486C: Standard for Splicing Wire
Connectors
UL 486D: Standard for Insulated Wire
Connectors for Use With Underground
Conductors
UL 486E: Standard for Equipment Wiring
Terminals for Use With Aluminum and/or
Copper Conductors
UL 493: Standard for ThermoplasticInsulated Underground Feeder and
Branch-Circuit Cables
UL 498: Standard for Attachment Plugs
and Receptacles
UL 514B: Standard for Fittings for Conduit
and Outlet Boxes
UL 719: Standard for NonmetallicSheathed Cables
UL 758: Standard for Appliance Wiring
Material - Component
UL 814: Standard for Gas-Tube-Sign and
Ignition Cable
UL 817: Standard for Cord Sets and
Power-Supply Cords
UL 854: Standard for Service-Entrance
Cables
UL 910: Standard for Test for FlamePropagation and Smoke-Density Values for
Electrical and Optical-Fiber Cables Used in
Spaces Transporting Environmental Air
UL 1023: Standard for Household BurglarAlarm System Units
UL 1063: Standard for Machine-Tool Wires
and Cables
UL 1072: Standard for Medium-Voltage
Power Cables
UL 1084: Standard for Hoistway Cables
UL 1263: Standard for Irrigation Cables

UL 183: Standard for Manufactured Wiring
Systems
Phone: 888-593-3355
www.generalcable.com

SPEC A025

January, 2010

Reference Standards
UL 1277: Standard for Electrical Power
and Control Tray Cables With Optional
Optical Fiber Members
UL 1309: Standard for Marine Shipboard
Cable
UL 1424: Standard for Cables for PowerLimited Fire-Protective-Signaling Circuits
UL 1426: Standard for Cables for Boats

UL 1588: Standard for Roof and Gutter
De-Icing Cable Units

UL 1807: Standard for Fire Resistant
Cable Coating Materials

UL 1666: Standard Test for Flame
Propagation Height of Electrical and
Optical-Fiber Cables Installed Vertically
in Shafts

UL 2023: Standard Test Method for
Flame and Smoke Characteristics of
Nonmetallic Wiring Systems (Raceway
and Conductors) for Environmental AirHandling Spaces

UL 1673: Standard for Electric Space
Heating Cables

UL 1446: Standard for Systems of
Insulating Materials—General

UL 1685: Standard for Vertical-Tray FirePropagation and Smoke-Release Test for
Electrical and Optical-Fiber Cables

UL 1462: Standard for Mobile Home Pipe
Heating Cable

UL 1690: Standard for Data Processing
(DP) Cables

UL 1569: Standard for Metal-Clad Cables

UL 1712: Standard Tests for Ampacity of
Insulated Electrical Conductors Installed
in the Fire Protective System

UL 1581: Reference Standard for
Electrical Wires, Cables and Flexible
Cords

Phone: 888-593-3355
www.generalcable.com

UL 2029: Standard for Gas/VaporBlocked Cable Classified for Use in Class
1 Hazardous (Classified) Locations
UL 2049: Standard for Residential Pipe
Heating Cable
UL 2556: Wire and Cable Test Methods
WC: See NEMA listing

SPEC A050

January, 2010

Checklist for Specifications
Control Cable
		Conductor Tape
		AWG
		Solid
___ Class B, concentric
___ Flexible
		Bare/Coated
		Insulation
		Jacket
		Temperature rating
		Voltage rating
		Individual Conductor Listings
		Number of Conductors
		Identification Method
___ Color code
___ Numbering
___ Tags
		Grounding
___ Bare/Coated
___ Size
___ Insulated

Power Cable
	 Size, AWG or kcmil
	 Conductor Type (metal)
	Stranding
___ Class B, compact
___ Class B, concentric
___ Class C
___ Other
	Bare/Coated
	 Conductor Shielding
___ Extruded
___ Tape
	Insulation
___ EPR
___ EVA
___ FEP
___ FR-EP
___ LSZH
___ Polyethylene/PVC
___ PVC/Nylon
___ Silicone
___ XLPE
___ Other
		Insulation Level
___ 100%
___ 133%

	 Insulation Shielding
___ Extruded
___ Tape
	 Metallic Shielding
___ Bare/Coated
___ Helical copper tapes
___ Helical wires
___ Longitudinal drain wires
___ Other
	 Jacket
___ CPE
___ CSPE
___ LSZH/XLPO
___ Neoprene
___ Polyurethane
___ PVC
___ XLPE
___ XL-CPE
___ XL-LSZH
___ Other
	 Cable Assembly
___ Cabled
___ Multiconductor
___ Other
		 Grounding Conductors
___ Bare/Coated
___ Insulated/Uninsulated
___ Quantity
___ Size
	 Neutral Conductors
___ Bare/Coated
___ Fillers
___ Flame-retardant
___ Fiber
___ Quantity
___ Insulated
___ Paper
___ Other
___ Size
	 Covering
___ C
 orrugated continuous
welded armor
___ Interlocked armor
___ Lead
___ Nonmetallic
___ Other
	 Color
	 Voltage rating
	 Temperature rating
	 Approvals

General Checklist
	 Standards
___ AEIC
___ CANENA
___ CSA
___ ICEA
___ IEC
	 ___ IEEE
___ UL
___ Other
	 Testing Procedures
___ AEIC
___ CAN ENA
___ CSA
___ ICEA
___ IEC
	 ___ IEEE
___ UL
___ Other
	 Special Requirements
___ Cold bend
___ Direct burial
___ Flame-retardant
___ Oil-resistant
___ Sunlight-resistant
___ Other
	 Documentation
___ Certificates of Compliance
___ Certified Test Reports
___ Drawings
___ Warranties
___ Other
	 System Characteristics
	 Shipping Details
___ Cut lengths
___ Installation recommendation
___ Lagging
___ Returnable reels
___ Other
	 Identification
___ Cable
___ Circuit
___ Reel
Note: This checklist must be
accompanied by exact system
details about the environment and
electrical characteristics.

Phone: 888-593-3355
www.generalcable.com

SPEC A075

January, 2010

NEC and CSA Designations
NEC WIRE
TYPE

AWM
MC-HL
ITC
MV-LS
MC
MTW
MV-90
MV-105
PLTC
RHH
RHW-2
SF-2
SFF-2
SIS
TC - ER
TFFN
TFN
THHN
THWN
USE-2
XHHW-2

DESCRIPTION
Appliance Wiring Material, Thermoplastic Insulation (PVC), With or Without Nylon, 105ºC, Dry Locations
Suffix “-HL” Indicates Acceptable for Hazardous Locations
Instrumentation Tray Cable, Several Combinations for Insulations and Jacket Compounds, CCW
Suffix “-LS” Indicates Acceptable for Limited Smoke Applications
Metal-Clad Cable, THHN or XHHW Individual Conductors, Aluminum or Steel Interlocked Armor, CCW
Machine Tool Wire, Thermoplastic Insulation (PVC), With or Without Nylon, 90ºC, Dry Locations
Medium-Voltage Cable Rated at 90ºC
Medium-Voltage Cable Rated at 105ºC
Power-Limited Tray Cable, Several Combinations of Insulations and Jacket Compounds, CCW
Rubber Equivalent Insulation (XLPE), High Heat-Resistant, 90ºC Rating, Dry or Damp Locations
Rubber Equivalent Insulation (XLPE), Heat-Resistant, 90ºC Rating, Wet Locations
Silicone Insulated Fixture Wire, Solid or 2-Strand
Silicone Insulated Fixture Wire, Flexible Strand
Flame-Retardant Thermoset Switchboard Wire
Tray Cable, Several Combinations of Insulation and Jacket Compounds, Cable Tray Use, Exposed Run
Thermoplastic Insulation (PVC), Flexible Fixture Wire, 90ºC Rating, Dry Locations, Nylon Jacket
Thermoplastic Insulation (PVC), Fixture Wire, 90ºC Rating, Dry Locations, Nylon Jacket
Thermoplastic Insulation (PVC), High Heat-Resistant, 90ºC Rating, Dry or Damp Locations, Nylon Jacket
Thermoplastic Insulation (PVC), Heat-Resistant, 75ºC Rating, Wet Locations, Nylon Jacket
Underground Service Entrance, Cross-Linked Polyethylene Insulation (XLPE), Direct Burial, 90ºC Rating
Cross-Linked Polyethylene Insulation (XLPE), High Heat-Resistant, 90ºC Rating, Wet and Dry Locations

CSA WIRE
TYPE

DESCRIPTION

AC-90

600 Volt XLPE Insulation, Aluminum or Steel Interlocked Armored Cable

ACIC

300 or 600 Volt Armored Instrument and Control Cable. A CSA-type designation used to describe Armored Instrumentation and
Control Cable. Available in either 300 Volt or 600 Volt with thermoset or thermoplastic insulation, this cable can be supplied with an
overall shield, shielded pairs, shielded triads or unshielded in multi-conductor constructions from 2 to 72 conductors. The overall
interlocked armor and PVC jacket provide a (-40ºC), HL, FT4 product (CSA Standard C22.2 No. 239).

ACWU90 (-40ºC)
HL (Hazardous
Locations)
NMD90
NMWU
RA90 (-40ºC)
RW90 XLPE (-40ºC)
RWU90 XLPE (-40ºC)
SEW-2
SEWF-2
TECK90 (-40ºC)
TC
TW75
TWU (-40ºC)

Phone: 888-593-3355
www.generalcable.com

600 Volt XLPE Insulation, Aluminum or Steel Interlocked Armored Cable with PVC Jacket
Designation for Hazardous Locations (CSA Standard C22.2 No. 174)
300 Volt Non-Metallic Sheath Cable with XLPE or PVC/Nylon Insulation
300 Volt Non-Metallic Sheath Cable with PVC Insulation
600 and 5000 Volt Single and Multiple Conductor with Seamless Corrugated Aluminum Armor. A CSA-type designation for singleconductor or multi-conductor constructions similar to AC90 and ACWU90, except no bonding (grounding) conductor is required in
the cable assembly. Also, the armor is a corrugated aluminum sheath, which serves as a bonding (grounding) conductor. The overall
PVC covering on RA90 is required for wet or direct burial applications (CSA Standard C22.2 No. 123).
600 and 5000 Volt Thermoset Insulation, 90ºC Rating, Wet or Dry Locations
600 and 1000 Volt Thermoset Insulation, 90ºC Rating, Direct Burial
600 Volt Silicone Rubber Insulated Equipment Wire, Solid or 7-Strand
600 Volt Silicone Rubber Insulated Equipment Wire with Flexible Strand
600 and 5000 Volt Single and Multiple Conductor Cable with Inner Jacket, Aluminum or Steel Interlocked Armor with PVC Jacket
Tray Cable Certified for Use in Class 1, Division 2 Areas
600 Volt Thermoplastic (PVC) Insulated Cable Suitable for Wet Locations
600 Volt Thermoplastic (PVC) Insulated Cable Suitable for Direct Burial

SPEC A100

May, 2013

Common Color Sequence
Method 1 Table E1 Color Sequence
COND.
NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

BACKGROUND
OR BASE
COLOR

FIRST
TRACER
COLOR

SECOND
TRACER
COLOR

Black

-

-

White

-

-

Red

-

-

Green

-

-

Orange

-

-

Blue

-

-

White

Black

-

Red

Black

-

Green

Black

-

Orange

Black

-

Blue

Black

-

Black

White

-

Red

White

-

Green

White

-

Blue

White

-

Black

Red

-

White

Red

-

Orange

Red

-

Blue

Red

-

Method 4 All Conductors Black
COND.
NO.

BACKGROUND
OR BASE
COLOR

20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37

FIRST
TRACER
COLOR

SECOND
TRACER
COLOR

Red

Green

-

Orange

Green

Red

Black

White

White

Black

Red

Red

Black

White
White

Green

Black

Orange

Black

White

Blue

Black

White

Black

Red

Green

White

Red

Green

Red

Black

Green

Green

Black

Orange

Orange

Black

Green

Blue

White

Orange

Black

White

Orange

White

Red

Orange

Orange

White

Blue

White

Red

Blue

COND.
1st
2nd
3rd
4th
5th

CONDUCTOR PRINTING
“1-One”
“2-Two”
“3-Three”
“4-Four”
“5-Five”

Pair cables are Black, White and numbered. Triad cables are Black, White, Red and numbered.

Method 1 Table E2 Color Sequence
COND.
NO.

BACKGROUND
OR BASE
COLOR

TRACER
COLOR

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Black

-

Red

-

Blue

-

Orange

-

Yellow

-

Brown

-

Red

Black

Blue

Black

Orange

Black

Yellow

Black

Brown

Black

Black

Red

Blue

Red

Orange

Red

Yellow

Red

Brown

Red

Black

Blue

Red

Blue

COND.
NO.
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

ANSI MC 96.1 Conductor Alloy and Color Code
BACKGROUND
OR BASE
COLOR

TRACER
COLOR

COND.
TYPE
EX

POSITIVE WIRE
ALLOY
COLOR
Chromel
Purple

NEGATIVE WIRE
ALLOY
COLOR
Constantan
Red

OUTER
JACKET
Purple

Orange

Blue

JX

Iron

White

Constantan

Red

Black

Yellow

Blue

KX

Chromel

Yellow

Alumel

Red

Yellow

TX

Copper

Blue

Constantan

Red

Blue

Brown

Blue

Black

Orange

Red

Orange

Blue

Orange

Yellow

Orange

Brown

Orange

Black

Yellow

Red

Yellow

Blue

Yellow

Orange

Yellow

Brown

Yellow

Black

Brown

Red

Brown

Blue

Brown

Orange

Brown

Yellow

Brown

Pair cables are Black, Red and numbered. Triad cables are Black, Red, Blue and numbered.
Colors repeat after 36 conductors. There are no Green or White conductors or stripes.

Phone: 888-593-3355
www.generalcable.com

SPEC A150

September, 2010

Metric Conversion Factors
	
	
	

To Convert From	
To	
Multiply By
Inches	
Millimeters	25.4
Millimeters	Inches	 0.03937

	
	
Length
	
	

Inches	
Centimeters	2.54
Centimeters	Inches	 0.3937

	
	
	
	

Kilofeet (1000 feet)	
Kilometers	
Square Inches	
Square Millimeters	

Kilometers	
Kilofeet (1000 feet)	
Square Millimeters	
Square Inches	

0.3048
3.2808
645.16
0.00155

	
	

Square Inches	
Square Centimeters	

Square Centimeters	
Square Inches	

6.4516
0.155

Area	
	

Square Inches	
Circular Mils	

Circular Mils	
Square Inches	

1,273,240
7.854 x 10-7

	
	

Circular Mils	
Square Millimeters	

Square Millimeters	
Circular Mils	

5.066 x 104
1973.51

	
	
	
	
Weight
	
	
	
	

Square Feet	
Square Meters	
0.0929
Square Meters	
Square Feet	
10.764
Pounds	
Kilograms	0.4536
Kilograms	 Pounds	2.2046

	
Electrical	

Microfarads/Kilofeet	
Microfarads/Kilometer	3.2808
Microfarads/Kilometer	 Microfarads/Kilofeet	0.3048

	
	
	
	

Mechanical	
	

Insulation Resistance:
Megohms—Kilofeet	
Megohms—Kilometer	
Pounds/Square Inch	
Kilo Pascal*	
Pounds (force)	

	

* 1 Pascal = 1 Newton/square meters

Phone: 888-593-3355
www.generalcable.com

Feet	
Meters	0.3048
Meters	 Feet	3.2808

Pound/Kilofeet	
Kilograms/Kilometer	1.4882
Kilograms/Kilometer	Pounds/Kilofeet	 0.6720
Ohms/Kilofeet	
Ohms/Kilometer	3.2808
Ohms/Kilometer	 Ohms/Kilofeet	0.3048

Megohms—Kilometer	0.3048
Megohms—Kilofeet	3.2808
Kilo Pascal*	
6.895
Pounds/Square Inch	
0.1432
Newtons	
4.448

SPEC A200
January, 2012

Reel Capacity Chart
Phone: 888-593-3355
www.generalcable.com

WOOD REELS
Reel (FxTxD)
RM Code
Arbor Hole
Drive Hole
Drive Hole Radius
Clearance
Factor
Max Weight
Net Weight
Cable OD
.241 - .250
.251 - .260
.261 - .270
.271 - .280
.281 - .290
.291 - .300
.301 - .310
.311 - .320
.321 - .330
.331 - .340
.341 - .350
.351 - .360
.361 - .370
.371 - .380
.381 - .390
.391 - .400
.401 - .410
.411 - .420
.421 - .430
.431 - .440
.441 - .450
.451 - .460
.461 - .470
.471 - .480
.481 - .490
.491 - .500
.501 - .525
.526 - .550
.551 - .575
.576 - .600
.601 - .625
.626 - .650
.651 - .675
.676 - .700
.701 - .725
.726 - .750
.751 - .775
.776 - .800
.801 - .825
.826 - .850
.851 - .875
.876 - .900
.901 - .925
.926 - .950
.951 - .975
.976 - 1.000
1.001 - 1.050
1.051 - 1.100
1.101 - 1.150
1.151 - 1.200
1.201 - 1.250
1.251 - 1.300
1.301 - 1.350
1.351 - 1.400
1.401 - 1.450
1.451 - 1.500
1.501 - 1.600
1.601 - 1.700
1.701 - 1.800
1.801 - 1.900
1.091 - 2.000
2.001 - 2.100
2.101 - 2.200
2.201 - 2.300
2.301 - 2.400
2.401 - 2.500
2.501 - 2.600
2.601 - 2.700
2.701 - 2.800
2.801 - 2.900
2.901 - 3.000
3.001 - 3.100
3.101 - 3.200
3.201 - 3.300
3.301 - 3.400
3.401 - 3.500

30x18x12
61-1215
2.75
1
4.5
1.5
509.3
750
47
11040
10200
9460
8800
8200
7660
7180
6740
6330
5970
5630
6320
5040
4780
4530
4310
4100
3910
3730
3560
3410
3260
3120
2990
2870
2760
2500
2280
2090
1920
1770
1630
1510
1410
1310
1230
1150
1080
1010
950
900
850
810
760
730
690
630
570
520
480
440
410
380
350
330
310
270
240

36x24x17
61-1659
3.06
1
6
2
1155.4
1500
91

10790
10110
9610
9030
8490
8100
7620
7300
6880
6600
6230
6000
5660
5450
5250
4970
4700
4630
4390
4040
3650
3310
3080
2810
2630
2400
2260
2070
1950
1840
1690
1610
1530
1450
1340
1280
1220
1170
1075
990
910
810
750
700
650
580
550
520
490
410
370
330

40x24x17
61-1808
3.06
1
6
2
1582.8
2000
110

10520
9940
9540
9030
8550
8220
7790
7510
7120
6880
6530
6310
6110
5530
5030
4580
4180
3910
3580
3280
3090
2840
2690
2480
2350
2230
2060
1970
1880
1735
1660
1590
1525
1360
1260
1120
1040
980
870
820
770
690
650
590
500
450
420

45x28x21
61-2056
3.06
1.5
8.5
2
2274.2
3000
142

12580
11940
11330
10910
10370
10000
9510
9180
8880
8050
7330
6680
6110
5590
5240
4820
4530
4180
3950
3650
3460
3200
3040
2900
2690
2570
2460
2280
2190
2010
1800
1670
1500
1400
1310
1180
1110
1040
990
840
760
650
600
540
500

50x32x24
61-2253
3.06
1.5
10
2
3227.7
4800
208

15010
14290
13790
13150
12700
11540
10510
9610
8800
8050
7430
6970
6430
5940
5610
5190
4920
4670
4340
4130
3850
3670
3510
3270
3130
2880
2590
2400
2160
2020
1820
1710
1610
1460
1370
1230
1060
960
880
760
700
650
600
520
490
460
430

58x32x28
61-2764
3.06
1.5
10
2
4468.6
6500
271

10420
9630
8900
8260
7800
7250
6870
6400
6090
5680
5420
5060
4840
4630
4340
3990
3600
3250
3030
2740
2570
2410
2190
2070
1950
1690
1520
1325
1210
1060
970
900
790
740
690
640
600
530
500
470
440
420
400
380

72x36x36
61-3655
3.06
1.5
10
2
7847.4
8000
513

84x36x48
61-4265
3.5
1.5
10
2
9658.4
9000
744

90x36x48
61-4366
3.5
1.5
10
3
11205.2
10,000
821

11530
10860
10250
9690
9170
8700
8250
7850
7120
6490
5930
5450
5020
4640
4320
4000
3730
3490
3070
2720
2420
2170
1960
1740
1620
1480
1360
1260
1160
1080
1000
930
870
820
770
720
680
640

11290
10700
10160
9660
8760
7980
7300
6710
6180
5720
5300
4930
4590
4290
3770
3340
2980
2680
2410
2190
2000
1830
1680
1550
1430
1320
1230
1150
1070
1010
940
890
840
790

11210
10160
9260
8470
7780
7170
6630
6150
5720
5330
4980
4380
3880
3460
3100
2800
2540
2320
2120
1950
1790
1660
1540
1430
1330
1250
1170
1090
1030
970
910

SPEC B005
January, 2010

Conductor Reference
TABLE 1  –	
		

Conductor Reference Table – Stranded Bare Copper
Conductor and Aluminum (ACM) Conductor

Stranded Bare Copper Conductor Standards
Conforms to:	 ASTM B3	
	
ASTM B8	
			
	
ASTM B33	
	
ASTM B172	
			
			
	
ASTM B173	
			
			
	
ASTM B174	
	
ASTM B496	
			

Soft or annealed copper wire
Concentric lay stranded
copper conductors Class B, C and D
Tinned soft or annealed copper wire
Rope lay stranded copper conductors
having bunch stranded members
Classes I, K and M
Rope lay stranded copper conductors
having concentric stranded members
Classes G and H
Bunch stranded copper conductors
Compact round concentric lay stranded
copper conductors

Concentric Stranding
Round
100%

Phone: 888-593-3355
www.generalcable.com

Compressed
97%

Compact
90%

SPEC B025
March, 2012

Class B Conductors for General Wiring
Copper Conductor
ASTM CLASS B
NOMINAL AREA
CIRCULAR MILS mm²

NOMINAL WEIGHT
LBS/1000 FT¹
kg/km

CONCENTRIC
NOMINAL O.D.
INCHES
mm

COMPRESSED
NOMINAL O.D.
INCHES
mm

COMPACT
NOMINAL O.D.
INCHES
mm

COND. SIZE
AWG/kcmil

STRANDING
INCHES

22

7/.0096

640

0.32

1.99

2.96

0.029

0.74

—

—

—

—

20

7/.0121

1,020

0.52

3.15

4.69

0.036

0.91

—

—

—

—

18

7/.0152

1,620

0.82

5.10

7.59

0.046

1.17

—

—

—

—

16

7/.0192

2,580

1.31

7.74

11.52

0.058

1.47

—

—

—

—

14

7/.0242

4,110

2.08

12.70

18.90

0.073

1.84

0.071

1.80

—

—

12

7/.0305

6,530

3.31

20.20

30.10

0.092

2.32

0.089

2.26

—

—

10

7/.0385

10,380

5.26

32.10

47.80

0.116

2.95

0.113

2.87

—

—

8

7/.0486

16,510

8.36

51

75.90

0.146

3.71

0.142

3.60

0.134

3.40

6

7/.0612

26,240

13.30

81.10

120.70

0.184

4.67

0.178

4.53

0.169

4.29

4

7/.0772

41,740

21.20

129

192

0.232

5.89

0.225

5.72

0.213

5.41

2

7/.0974

66,360

33.60

205

305.10

0.292

7.42

0.283

7.19

0.268

6.81

1

19/.0664

83,690

42.40

258

383.90

0.332

8.43

0.322

8.18

0.299

7.59

1/0

19/.0745

105,600

53.50

326

485.10

0.373

9.47

0.362

9.19

0.336

8.53

2/0

19/.0837

133,100

67.40

411

611.60

0.419

10.64

0.406

10.32

0.376

9.55

3/0

19/.0940

167,800

85

518

770.90

0.470

11.94

0.456

11.58

0.423

10.74

4/0

19/.1055

211,600

107

653

971.80

0.528

13.41

0.512

13.01

0.475

12.07

250

37/.0822

250,000

127

772

1148.90

0.575

14.61

0.558

14.17

0.520

13.21

300

37/.0900

300,000

152

926

1378

0.630

16.00

0.611

15.52

0.570

14.48

350

37/.0973

350,000

177

1,081

1609

0.681

17.30

0.661

16.78

0.616

15.65

400

37/.1040

400,000

203

1,235

1838

0.728

18.49

0.706

17.94

0.659

16.74

500

37/.1162

500,000

253

1,544

2298

0.813

20.65

0.789

20.03

0.736

18.69

600

61/.0992

600,000

304

1,883

2802

0.893

22.68

0.866

22.00

0.813

20.65

750

61/.1109

750,000

380

2,316

3447

0.998

25.35

0.968

24.59

0.908

23.06

1000

61/.1280

1,000,000

507

3,088

4595

1.152

29.26

1.117

28.38

1.060

26.92

Dimensions and weights are nominal; subject to industry tolerances.
¹ Nominal conductor weights are applicable for Concentric Class B and Compressed Stranding per ASTM B8.

Phone: 888-593-3355
www.generalcable.com

SPEC B030

February, 2011

Class C Conductors for General Wiring
Copper Conductor
ASTM CLASS C
SIZE

STRANDING

AWG/kcmil

INCHES

NOMINAL AREA
CIRCULAR
MILS
mm 2

NOMINAL DIAMETER
INCHES

mm

NOMINAL WEIGHT
LBS/KFT

kg/km

22

19/.0063

640

0.32

0.031

0.79

2.34

3.48

20

19/.0080

1,020

0.52

0.038

0.97

3.71

5.52

18

19/.0092

1,620

0.82

0.044

1.12

5.00

7.40

16

19/.0117

2,580

1.31

0.056

1.42

7.97

11.86

14

19/.0147

4,110

2.08

0.070

1.80

12.70

18.90

12

19/.0185

6,530

3.31

0.089

2.24

20.20

30.10

10

19/.0234

10,380

5.26

0.112

2.85

32.05

47.80

9

19/.0262

13,090

6.63

0.126

3.20

40.40

60.10

8

19/.0295

16,510

8.37

0.143

3.63

51.00

74.40

7

19/.0331

20,820

10.50

0.162

4.11

64.30

95.70

6

19/.0372

26,240

13.30

0.184

4.67

81.00

121

5

19/.0417

33,090

16.80

0.203

5.16

102

152

4

19/.0469

41,740

21.20

0.235

5.97

129

192

3

19/.0526

52,620

26.70

0.263

6.68

163

243

2

19/.0591

66,360

33.60

0.296

7.52

205

305

1

37/.0476

83,690

42.40

0.323

8.20

258

384

1/0

37/.0534

105,600

53.50

0.362

9.20

326

485

2/0

37/.0600

133,100

67.40

0.407

10.33

411

612

3/0

37/.0673

167,800

85

0.457

11.60

518

771

4/0

37/.0756

211,600

107

0.513

13.03

653

972

250

31/.0640

250,000

127

0.558

14.17

774

1150

262.6

—

300

61/.0701

313.1

—

350

61/.0757

373.7

—

400

61/.0810

444.4

—

500

61/.0905

—
300,000
—
350,000
—
400,000
—
500,000

—

—

—

—

—

152

0.612

15.54

927

1380

—

—

—

—

—

177

0.661

16.79

1082

1610

—

—

—

—

—

203

0.711

18.10

1235

1838

—

—

—

—

—

253

0.791

20.10

1545

2299

535.3

—

—

—

—

—

—

—

592

—

—

—

—

—

—

—

304

0.893

22.70

1853

2757

—

—

—

—

—

380

0.999

25.40

2316

3446

600

91/.0812

646.4

—

600,000

750

91/.0908

777.7

—

—

—

—

—

—

—

1000

91/.1048

1,000,000

507

1.153

29.30

3088

4595

1111

—

—

—

—

—

—

—

—
750,000

Dimensions and weights are nominal; subject to industry tolerances.

Phone: 888-593-3355
www.generalcable.com

SPEC B035

February, 2011

Class H Conductors for General Wiring
Copper Conductor
ASTM CLASS H
SIZE

STRANDING

AWG/kcmil

INCHES

NOMINAL AREA
CIRCULAR
MILS
mm²
—

NOMINAL DIAMETER
INCHES

NOMINAL WEIGHT

mm

LBS/KFT

kg/km

—

—

9

—

—

—

—

8

133/.0111

16,510

8.37

0.164

4.17

52

77

7

133/.0126

20,820

10.50

0.190

4.83

67

100

6

133/.0140

26,240

13.30

0.204

5.18

82

122

5

133/.0158

33,090

16.80

0.231

5.87

105

156

4

133/.0177

41,740

21.20

0.260

6.60

132

196

3

133/.0199

52,620

26.70

0.292

7.42

167

248

2

133/.0223

66,360

33.60

0.327

8.31

208

310

1

259/.0180

83,690

42.40

0.363

9.22

266

396

1/0

259/.0202

105,600

53.50

0.407

10.30

334

497

2/0

259/.0227

133,100

67.40

0.458

11.60

422

628

3/0

259/.0255

167,800

85

0.515

13.10

533

793

4/0

259/.0286

211,600

107

0.579

14.70

670

997

250,000

127

0.627

15.90

795

1183

—

—

—

152

0.702

17.80

—

—

—

177

0.740

18.80

1110

1652

—

—

—

—

—

203

0.809

20.50

1270

1890

—

—

—

—

—

253

0.900

22.90

1590

2366

—

—

—

—

—

250

427/.0242

262.6

—

300

427/.0265

313.1

—

350

427/.0286

373.7

—

400

427/.0306

444.4

—

500

427/.0342

535.3

—

592

—

600

703/.0292

646.4

—

750

703/.0327

—
300,000
—
350,000
—
400,000
—
500,000
—
—
600,000
—
750,000

—
953
—

—
1418
—

—

—

—

—

—

304

1.022

26.00

1920

2857

—

—

—

—

—

380

1.122

28.50

2410

3586

777.7

—

—

—

—

—

—

—

1000

703/.0377

1,000,000

507

1.294

32.90

3205

4769

1111

—

—

—

—

—

—

—

Dimensions and weights are nominal; subject to industry tolerances.

Phone: 888-593-3355
www.generalcable.com

SPEC B040
March, 2012

Class I Conductors for General Wiring
Copper Conductor
ASTM CLASS I
SIZE

STRANDING

AWG/kcmil

INCHES

10
9
8
7
6

27/.0201
—
37/.0201
—
61/.0201

NOMINAL AREA
CIRCULAR
MILS
mm2
10,910
—
14,950
—
24,640

NOMINAL DIAMETER

NOMINAL WEIGHT

INCHES

mm

LBS/KFT

5.53

0.117

2.97

33.70

—

—

—

—

7.57

0.135

3.43

46

kg/km
50
—
68

—

—

—

—

—

12.50

0.174

4.42

77

114

5

91/.0201

36,760

19

0.242

6.15

116

173

4

105/.0201

42,420

21

0.262

6.60

137

204

3

126/.0201

50,500

25

0.285

7.24

167

249

2

147/.0201

60,600

31

0.307

7.80

190

283

1

224/.0201

90,900

46

0.380

9.65

287

427

1/0

273/.0201

111,100

56

0.410

10.41

351

522

2/0

323/.0201

131,300

66

0.470

11.90

407

606

3/0

456/.0201

184,200

92

0.549

13.94

594

884

4/0

551/.0201

222,600

112

0.593

14.70

696

1035

—

—

—

—

—

133

0.630

820

1220

—

—

—

—

—

159

0.685

17.40

987

1469

—

—

—

—

—

189

0.750

1176

1750

—

—

—

—

—

225

0.820

20.80

1413

2103

—

—

—

—

—

250
262.6
300
313.1
350
373.7

—
646/.0201
—
777/.0201
—
925/.0201

400

—

444.4

1110/.0201

500

—

—
261,000
—
313,900
—
373,700
—
448,400
—

16

19

535.3

1332/.0201

538,100

271

0.895

22.70

1697

2525

592

1480/.0201

597,900

303

0.972

24.70

1858

2765

600

—

646.4

1591/.0201

750

—

777.7

1924/.0201

—
642,800
—
777,700

—

—

—

—

—

327

0.980

24.90

2020

3006

—

—

—

—

—

394

1.075

27.30

2435

3624

1000

—

—

—

—

—

—

—

1111

2745/.0201

1,111,000

563

1.328

33.70

3400

5059

Dimensions and weights are nominal; subject to industry tolerances.

Phone: 888-593-3355
www.generalcable.com

SPEC B045
March, 2012

Class K Conductors for General Wiring
Copper Conductor
ASTM CLASS K
SIZE

STRANDING

AWG/kcmil

INCHES

22

—

NOMINAL AREA
CIRCULAR
MILS
mm2
—

NOMINAL DIAMETER
INCHES

mm

NOMINAL WEIGHT
LBS/KFT

kg/km

—

—

—

—

—

20

10/.010

1,020

0.52

0.036

0.91

3.2

4.8

18

16/.010

1,620

0.82

0.046

1.20

5

7.4

16

26/.010

2,580

1.31

0.057

1.40

7.97

12

14

41/.010

4,110

2.08

0.071

1.80

12.8

19

12

65/.010

6,530

3.31

0.088

2.20

20.3

30.2

10

105/.010

10,380

5.26

0.112

2.80

33.3

49.6

9

133/.010

13,090

6.63

0.150

3.80

42.4

63.1

8

168/.010

16,510

8.37

0.164

4

53.2

80.8

7

210/.010

20,820

10.50

0.175

4.40

66.8

99.4

6

266/.010

26,240

13.30

0.198

5.00

84.2

125
158

5

336/.010

33,090

16.80

0.261

6.60

106

4

420/.010

41,740

21.20

0.249

6.30

132

196

3

532/.010

52,620

26.70

0.298

7.60

169

251

2

665/.010

66,360

33.60

0.317

8.10

211

314

1

836/.010

83,690

42.40

0.356

9

266

396

1/0

1064/.010

105,600

53.50

0.401

10

338

503

2/0

1323/.010

133,100

67.40

0.501

13

425

632

3/0

1666/.010

167,800

85

0.562

14

535

796

4/0

2107/.010

211,600

107

0.627

15.93

676

1006

250

2499/.010

250,000

127

0.688

17

802

1193

262.6

2220/.010

222,000

112

0.680

17

824

1226

300

2989/.010

300,000

152

0.753

19

960

1428

313.1

3136/.010

313,600

159

0.750

19

969

1442

350

3458/.010

350,000

177

0.818

21

1120

1667

373.7

3737/.010

373,700

189

0.790

20

1210

1800

400

3990/.010

400,000

203

0.878

22

1290

1920

444.4

—

—

—

—

—

—

500

5054/.010

500,000

—

253

0.990

25

1635

2433

535.3

5320/.010

532,000

270

0.950

24

1641

2442

592

—

—

—

—

—

—

—

600

5985/.010

600,000

340

1.125

29

1950

2902

646.4

6466/.010

646,600

328

1.040

26

1987

2957

750,000

750

7448/.010

380

1.276

32

2427

3611

777.7

—

—

—

—

—

—

—

1000

9975/.010

1,000,000

507

1.498

38

3250

4769

1111

—

—

—

—

—

—

—

Dimensions and weights are nominal; subject to industry tolerances.

Phone: 888-593-3355
www.generalcable.com

SPEC C005

September, 2012

Jacket and Insulation Material Properties
Thermoplastic Properties
INSULATION
OR JACKET
MATERIAL

CHLORINATED
POLYETHYLENE
(CPE)

POLYVINYL
CHLORIDE
(PVC)

LOW-DENSITY
POLYETHYLENE

CELLULAR
POLYETHYLENE

Oxidation
Resistance

E

E

E

E

E

E

E

E

O

E

Heat
Resistance

G-E

G-E

G

G-E

E

E

G

E

O

G

Oil
Resistance

E

E

G-E

G-E

G-E

E

E

E

O

P

Low Temp.
Flexibility

G

P-G

G-E

E

E

E

G

G

O

E

Weather,
Sun Resistance

E

G-E

E

E

E

E

F-G

E

O

—

Ozone
Resistance

E

E

E

E

E

E

E

E

E

E

Abrasion
Resistance

E

F-G

F-G

G

E

F-G

O

E

G-E

F

Electrical
Properties

G

F-G

E

E

E

E

P-F

F

E

G

Flame
Resistance

E

G

P

P

P

P

P

P

O

F

Nuclear
Radiation
Resistance

G-E

P-F

G

G

G

F

G

F-G

P-F

F

Water
Resistance

E

G-E

E

E

E

E

P

P-F

E

E

Acid
Resistance

G-E

G-E

G-E

G-E

G-E

E

F

P-F

E

G

Alkali
Resistance

G-E

G-E

G-E

G-E

G-E

E

F

E

E

G

G

G

P-F

P-F

P-F

P-F

F

G

E

P

G

P-F

P

P

P

P-F

P

G

E

P

Degreaser
Solvents
(Halogenated
Hydrocarbons)
Resistance

F

P-F

P

P

P

P

P

G

E

P

Alcohol
Resistance

G

G-E

E

E

E

E

P

P

E

E

Gasoline,
Kerosene, Etc.
(Alaphatic
Hydrocarbons)
Resistance
Benzol,
Toluol, Etc.
(Aromatic
Hydrocarbons)
Resistance

HIGHPOLYPOLYDENSITY
NYLON TEFLON
POLYETHYLENE URETHANE PROPYLENE

®

TPE

P	=	Poor
F	 =	Fair
G	=	Good
E	=	Excellent
O	=	Outstanding
Phone: 888-593-3355
www.generalcable.com

Any given property can usually be improved by the use of selective compounding.
Dimensions and weights are nominal; subject to industry tolerance.

SPEC C010

January, 2010

Jacket and Insulation Material Properties
Thermoset Properties
NITRILE
HYPALON
STYRENE
OR
NITRILE/ ETHYLENE CROSS-LINKED CHLORINATED
CHLOROBUTADIENE NATURAL SYNTHETIC
POLYRUBBER
POLY- PROPYLENE
NEOPRENE
SULFONATED
POLYETHYLENE SILICONE
RUBBER RUBBER RUBBER BUTADIENE
BUTADINE CHLORIDE RUBBER POLYETHYLENE
RUBBER
POLYETHYLENE
(XLPE)
(CPE)
(SBR)
NITRILE (NBR/PVC)
(EPR)
(CSPE)
(NBR)
®

INSULATION
OR JACKET
MATERIAL

Oxidation
Resistance

F

F

G

G

G

E

F

E

G

E

E

E

Heat
Resistance

F-G

F

F

F

G

E

G

G

E

G

E

G

Oil
Resistance

P

P

P

P

G

G

G-E

G

F

G

G-E

F-G

Low Temp.
Flexibility

F-G

G

E

E

F-G

F

F

F

G-E

O

F

O

Weather, Sun
Resistance

F

F

F

F

G

E

F-G

G

E

G

E

O

Ozone
Resistance

P

P

P

P

G

E

P

G

E

E

G-E

O

Abrasion
Resistance

G-E

E

E

E

G-E

G

G-E

E

G

F-G

G-E

F

Electrical
Properties

E

E

E

E

F

G

P

F

E

E

F-G

O

P

P

P

P

G

G

P

G

P

F-G

G

F-G

F-G

F-G

F-G

P

F-G

G

F-G

P

G

E

G

E

G-E

G-E

E

E

G

G-E

G-E

E

G-E

G-E

G-E

G-E

Acid
Resistance

F-G

F-G

F-G

F-G

G

E

G

G

G-E

G-E

E

F-G

Alkali
Resistance

F-G

F-G

F-G

F-G

G

E

F-G

G

G-E

G-E

E

F-G

P

P

P

P

G

F

E

G-E

P

F

F

P-F

P

P

P

P

P-F

F

G

G

F

F

F

P

P

P

P

P

P

P-F

P

G

P

F

P

P-G

F

G

G

F-G

F

G

E

G

P

E

G-E

G

Flame
Resistance
Nuclear
Radiation
Resistance
Water
Resistance

Gasoline,
Kerosene, Etc.
(Alaphatic
Hydrocarbons)
Resistance
Benzol,
Toluol, Etc.
(Aromatic
Hydrocarbons)
Resistance
Degreaser
Solvents
(Halogenated
Hydrocarbons)
Resistance
Alcohol
Resistance
P	=	Poor
F	 =	Fair
G	=	Good
E	=	Excellent
O	=	Outstanding

Any given property can usually be improved by the use of selective compounding.
Dimensions and weights are nominal; subject to industry tolerance.

Phone: 888-593-3355
www.generalcable.com

SPEC D005

May, 2013

Recommended Reel Handling Practices
How to Handle Cable Reels

YES

Phone: 888-593-3355
www.generalcable.com

NO
Cradle both reel flanges between forks.

Do not lift by top flange. Cable or reel
will be damaged

Reels can be hoisted with a shaft
extended through both flanges..

Use a spreader bar to prevent bending
the reel flanges and mashing the cable.

Always load with flanges on edge and
chock and block securely.

Upended heavy reels will often arrive
damaged. Refuse or receive subject to
inspection for hidden damage.

Lower reels from truck using hydraulic
gate, hoist or fork lift. LOWER CAREFULLY.

Never allow forks to touch cable surface
or reel wrap.

Always load with flanges on edge and
chock and block securely.

Never drop reels.

SPEC D025

October, 2011

Recommended Cable Handling Practices
Unloading and Moving of Reels:
Cable reels are never shipped upended (flat side down). Cable reels that arrive in this manner should be rejected
or received only after a thorough inspection for damage.
See “Recommended Reel Handling Practices” page.
Upon receipt, a cable’s protective covering and/or lagging should be inspected for evidence of damage during
shipment. If evidence of damage is found, a report should immediately be made to the carrier.
Under no circumstances should reels be dropped from the delivering vehicle to the ground.
Unloading and reel handling should be accomplished so that the equipment used does not contact the cable
surface, and in the case of protective wrap, that the equipment does not contact the protective wrap.
If unloading and reel handling is accomplished by crane, either a cradle supporting the reel flanges or a shaft
through the arbor hole should be used. If a fork lift is utilized, the forks must lift the reel at 90˚ to the flanges
and the forks must be long enough to make complete lifting contact with both flanges. Under no circumstances
should the forks come into contact with the cable surface or the protective wraps.
When a reel of cable is rolled from one point to another, care must be taken to see that there are no objects on
the surface area which could contact or damage the cable surface or protective wrap.
If an inclined ramp is used for unloading, the ramp must be wide enough to contact both flanges completely.
The stopping of the reels at the bottom shall be accomplished by using the reel flanges and not the surface of
the cable.

Minimum Drum Diameters for Packaging Cables
Type of Cable

Minimum Drum Diameter as a
Multiple of Outside
Diameter of Cable

1.	Single and multiple conductor cable - unshielded 0-2000 V

10

2.	Single and multiple conductor cable - unshielded 2400 V

12

3.	Single and multiple conductor cable - wire shield (UniShield )
	 5-35 kV

12

4.	Single and multiple conductor cable - helically applied tape shield
	(Uniblend ) 5-35 kV

14

5.	Single and multiple conductor cable - longitudinally applied flat
	 tape shield (Type TC)

20

®

®

6.	Single and multiple conductor cable - Interlocked Armor (Duralox )
	 600 V-35 kV

14

7.	 Triplexed single conductors cabled together. The circumscribing	
	 overall diameter* shall be multiplied by the factor in 1 - 6 and then
	 by the reduction factor.

.75

®

*Single conductor times 2.155 times
NEMA WC26 EEMAC201-2007 Binational Wire and Cable Packaging Standard

Phone: 888-593-3355
www.generalcable.com

SPEC D050

May, 2013

Recommended Cable Storage Practices
Storage and Storage Maintenance:
Finished cables have no established shelf-life. Moisture and atmospheric conditions can cause exposed
conductors to oxidize and discolor. Uncovered/unsheltered cable will degrade due to exposure to direct sunlight
and/or the elements. If the cables are protected, there should be no degradation of the insulation.
In general, any cable for use indoors should be stored indoors. Any cable suitable for installation outdoors is
suitable for storage outdoors. Cables stored outdoors should have the ends sealed to prevent moisture ingress
into the cable and should be used within two years or less.
Cables should be stored in a sheltered area. The cable conductor should not be exposed to water.
Cables with a cold temperature marking, e.g. –10˚C, –25˚C, or –40˚C, may be stored outdoors. Cables without a
cold temperature marking must be stored indoors.
Cable reels must remain in the upright position. Cable reels must not be stored on their sides. Reels must not be
stacked.
Cable reels should be stored with the protective covering or lagging in place. If a length of cable has been cut
from the reel, the cable end should be immediately resealed to prevent the entrance of moisture. If a part length
is returned to storage, the reel’s protective covering should be restored.
Wooden reels should be stored off the ground to prevent rotting. Reels should be stored on a flat, hard surface
so that flanges do not sink into the earth. The weight of the reel and cable must be carried at all times by the reel
flanges.
Cable reels and lagging must not be stored for an extended time period sitting in direct contact with water or
dampness. Timbers or metal supports must be placed under the reel flanges to provide elevated storage of the
reels away from the direct contact with water or damp soil.
Reels should be stored in an area where construction equipment, falling or flying objects or other materials will
not contact the cable.
Cable should be stored in an area where chemicals or petroleum products will not be spilled or sprayed on the
cable.
Cable should be stored in an area away from open fires or sources of high heat.
If the reels are relocated, they should be handled as suggested in the “Recommended Reel Handling Practices”
section, and inspection made on each reel during the relocation.
If the cables are stored in a secure area and not exposed to the effects of the weather, an annual inspection
should be satisfactory.
Where the reels are exposed to the weather, a bimonthly inspection should be performed to observe any sign of
deterioration.
If the reels are exposed in a non-secure area, policing of the area at frequent intervals may be required
depending on circumstances.
Records of delivery date, manufacturer, installation date, any extenuating circumstances, along with all test
reports, should be kept on file.

Phone: 888-593-3355
www.generalcable.com

SPEC E005
April, 2010

Pre-Installation Instructions
Pre-Installation

Overview

Cable Inspection

Cabling Handling

To ensure safety during cable installation
and reliability once the cable is installed,
you should confirm the following prior to
installation:

Inspect every cable reel for damage before
accepting the shipment. Be particularly alert
for cable damage if:

Remove all nails and staples from the reel
flanges before moving a reel, and avoid all
objects that could crush, gouge or impact
the cable when moving. NEVER use the
cable as a means to move a reel.

•	 The cable selected is proper for your
application

•	 Several reels are stacked

•	 The cable has not been damaged in
transit or storage
Review all applicable state and national codes
to verify that the cable chosen is appropriate
for the job. Also, consult your local building
authority.
Next, you must identify any existing cable
damage and prevent any further damage
from occurring. This is done through proper
cable inspection, handling and storage.

•	 A reel is laying flat on its side

•	 Other freight is stacked on a reel

When unreeling, observe recommended
bending radii, use swivels to prevent
twisting and avoid overruns.

•	 Nails have been driven into reel flanges to
secure shipping blocks
•	 A reel flange is damaged
•	 A cable covering is removed, stained or
damaged
•	 A cable end seal is removed or
damaged
•	 A reel has been dropped
(hidden damage likely)

Phone: 888-593-3355
www.generalcable.com

SPEC E025

January, 2011

Installation – Overview and Checklist
Installation

Overview

Installation Temperature

Equipment

Most cables are subjected to more
mechanical stress during installation than
they ever experience in actual operation.
Needless to say, handling and pulling your
cable according to manufacturer’s recommendations is extremely important.

Low temperatures are a cause for
concern when installing cable. Cable
should not be installed when temperatures
are less than the cold bend temperature
rating of the cable product plus 15°C (i.e.,
minimum installation temperature = cold
bend temperature rating + 15°C). The cold
bend temperature rating is indicated on
the catalog Spec sheet.

The proper use of appropriate equipment
is crucial to a successful cable installation.
The equipment needed for most installations is detailed in the following checklist:

There are six main considerations in any
cable installation:
•	 Ambient temperature
•	 Equipment
•	 Conduit fill
•	 Mechanical fit in raceway
•	 Physical limitations
•	 Knowledgeable installers
For more information, reference
IEEE 1185 Recommended Practices for
Cable Installations in Generating Stations
and Industrial Facilities.

Phone: 888-593-3355
www.generalcable.com

Prior to performing a low temperature
(less than 10°F or -12˚C) cable installation,
cable should be stored for a minimum of
24 hours at a temperature of 55°F (13˚C)
or higher.
Cable should be pulled more slowly
and trained in place the same day it is
removed from storage. Do not impact,
drop, kink or bend cable sharply in low
temperatures.

	 0-1/5/10 kip dynamometer
	 basket grip pullers
	 cable cutter
	 cable end seals
	 cable pulling lubricant
	 cable tray bend sheaves
	 cable tray rollers
	 capstan-type puller
	 diameter tape
	 duct cleaning mandrels
	 electric safety blankets and clamps
	 extension cords and GFCI protection
	 fish tape or string blower/vacuum
	floodlights
	gang rollers: with at least 4 ft.
effective radius
	gloves
	 guide-in flexible tubing (elephant trunks)
	 hand winches (come-a-long)
	 HI-POT tester
	 lint-free rags
	 make-up air blower & hose
	 manhole edge sheave
	 measuring tape
	 personal protection equipment (PPE)
	 plywood sheets
	 portable electric generator
	 pre-lubing devices
	 pulling rope
	 pump, diaphragm
	 radios or telephones
	 reel arbor
	 reel brakes
	 reel jacks
	several wire rope slings of various
lengths
	shackles/clevis
	 short ropes for temp tie-offs
	swivels
	 warning flags, signs

SPEC E050

April, 2010

Installation – Feed-In Setups

Cable Feed-In Setups

The following diagrams illustrate various cable feed-in setups:
Apply lube here
Guide-in tube

Reels on truck

Setup for duct close to floor

Setup for overhead, into tray

The feed-in setup should unreel the
cable with a natural curvature
(Figure 1) as opposed to a reverse
“S” curvature (Figure 2).

PROPER

Figure 1

IMPROPER

Figure 2

Phone: 888-593-3355
www.generalcable.com

SPEC E050

April, 2010

Installation – Feed-In Setups

Cable Feed-In Setups (continued)

Single Sheave
Single sheaves should only be
used for GUIDING cables. Arrange
multiple blocks to maintain bending
radii whenever cable changes
direction or elevation.

For pulling around bends,
use conveyor sheave
assemblies of the
appropriate radius series.

Sheave Assembly

The pulleys must be positioned to ensure that
the effective curvature is smooth and changes
direction or elevation evenly at each pulley.
Never allow a polygon curvature to occur
(Figure 3).
The fit of a pulley around the cable is also
important when pulling heavy weights
(i.e. pulleys at the top of a vertical drop).

NEVER ALLOW
Figure 3

Remember to use the radius of the
surface over which the cable is bent,
not the outside flange diameter of
the pulley. A “10 inch” cable sheave
typically has a 10 inch outside flange
diameter with a 6 inch inside diameter
that provides an inside (bending)
radius of 3 inches.

Radius

Phone: 888-593-3355
www.generalcable.com

SPEC E075

October, 2012

Installation – Conductor Maximum Pulling Tensions
Multi-Conductor Cables Having Equal-Sized Conductors;
In Parallel or as Multiplexed Assemblies

MAXIMUM ALLOWABLE PULLING TENSION (LBS)
NUMBER OF CONDUCTORS

AWG/kcmil

1

2

3

4

5

6

18
16
14
12
10
8
6
4
2
1
1/0
2/0

13
20
33

26
40
66

39
60
99

41
65
105

52
81
132

62
97
158

52
83
132

104
166
264

157
249
396

167
266
423

209
332
528

251
399
634

210
334
531

420
668
1062

630
1002
1593

672
1069
1699

840
1336
2124

1008
1603
2548

670
845
1065

1339
1690
2130

2009
2534
3194

2142
2703
3407

2678
3379
4259

3214
4055
5111

1342
1693
2000

2685
3386
4000

4027
5078
6000

4296
5417
6400

5370
6771
8000

6444
8125
9600

2800
4000
6000

5600
8000
10000

8400
10000
10000

8960
10000
10000

10000
10000
10000

10000
10000
10000

8000

10000

10000

10000

10000

10000

3/0
4/0
250
350
500
750
1000

The maximum allowable pulling tensions are for direct attachment to the conductor.
T = 0.008 x cmil x n, if n ≤ 3
T = 0.008 x cmil x n x 0.8, if n > 3
When more than two conductors are pulled in parallel in an installation containing bends, the maximun allowable pulling tension is limited
to the two conductor column, regardless of the number of conductors that are being pulled.

Phone: 888-593-3355
www.generalcable.com

SPEC E075

October, 2012

Installation – Conductor Maximum Pulling Tensions

Multi-Conductor Cables Having Equal-Sized Conductors, without Subassemblies
MAXIMUM ALLOWABLE PULLING TENSION (LBS)

NUMBER OF
CONDUCTORS
2
3
4
5
6
7
8
9
10
12
14
15
16
18
19
20
22
24
25
30
37

CONDUCTOR SIZE (AWG/kcmil)

18

16

14

12

10

26
39
41

40
60
65

66
99
105

104
157
167

166
249
266

52
62
73

81
97
113

132
158
184

209
251
293

332
399
465

83
93
104

129
145
161

210
237
263

334
376
418

531
598
664

124
145
156

194
226
242

316
368
395

502
585
627

797
930
996

166
187
197

258
290
306

421
473
500

669
752
794

1000
1000
1000

207
228
249

323
355
387

526
549
631

836
919
1000

1000
1000
1000

259
311
383

403
484
596

658
789
974

1000
1000
1000

1000
1000
1000

The maximum allowable pulling tensions are for multi-conductor cables pulled into a raceway or cable tray using a basket grip or similar
device secured directly to the cable jacket. It is recommended that a combination of basket grips and pulling eyes be used whenever possible.
T = 0.008 x cmil x n, if n ≤ 3
T = 0.008 x cmil x n x 0.8, if n > 3

Phone: 888-593-3355
www.generalcable.com

SPEC E100

April, 2010

Installation – Training and Bending Limitations
Physical Limitations Training and Bending
Overview
Training is the positioning of cable when
it is not under tension. Bending is the
positioning of cable when it is under
tension. When installing cable, the object
is to limit the mechanical forces so that
the cable’s physical and electrical
characteristics are maintained for the
expected service life. Bends in conductors,
multi-conductor cables or assemblies of
conductors shall be made so that the cable
will not be damaged.

A nonshielded cable can tolerate a sharper
bend than a shielded cable. This is
especially true for cables having helically
applied metallic shielding tapes which,
when bent too sharply, can separate or
buckle and cut into the insulation.
Remember that offsets are bends.

The problem is compounded by the fact
that most tapes are under jackets that
conceal such damage. The extruded
polymers used for insulation shields have
sufficient conductivity and coverage
initially to pass acceptance testing, then
fail prematurely due to corona at the
shield/insulation interface.

Minimum Bending Radius in Accordance with National Electric Code
Voltage Conductors Shielding Cable Types
600 V
6012000 V

Single

Nonshielded

All

5X

All

8X

Nonshielded TC or TC-ER

600 V
or
2000 V

Multiconductor
or
Multiplexed
Shielded

Over
2000 V

	
	
	
	
	
3
	
1
2

1 in. (25 mm)
or less
4X

MC

3

All

Single

Minimum Bending Radius as a Multiple
of Conductor/Assembly Diameter

Nonshielded
Shielded

MultiNonshielded
conductor or
Shielded
Multiplexed

Over 1 in. to 2 in.
(>25 mm to 50
mm)

Over 2 in.
(>50 mm)

5X

6X

7X
12X

TC or TC-ER

12X

MC

12X/7X

MV
MC

3

MC and MV
MC and MV
MC and MV

1

8X
7X
12X

2

8X
1,2

12X/7X

12 times the diameter of an individual shielded conductor or 7 times the overall cable diameter, whichever is greater.
Since UniShield is a unique construction, there are no applicable values for the bending radius in the NEC. However,
General Cable recommends 8 times for single conductors, and for multiplexed or multi-conductor cables, it is 8 times
the diameter of the individual conductors or 5 times the overall diameter, whichever is greater, in accordance with
ANSI/ICEA S-93-639 5-46 kV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy.
Per 330.24B Interlocked-Type Armor or Continuously Corrugated Metallic Sheath.
®

Phone: 888-593-3355
www.generalcable.com

SPEC E125

October, 2012

Installation – Maximum Sidewall Pressure
Overview
Sidewall bearing pressure (SWBP), or sidewall
loading, is the radial force exerted on a cable being
pulled around a conduit bend or sheave. Excessive
SWBP can crush a cable and is, therefore, one of
the most restrictive factors in installations having
bends and requiring high pulling tensions. SWBP is
reduced by increasing the radius of bends.

Tension

The maximum tension that can safely be applied
to the cable during installation can be calculated
using the maximum SWBP for the cable and the
radius of the bend it is traversing.
For example, a cable having a maximum SWBP of
300 lb/ft that is being pulled around a bend having
a radius of 2 feet should have no more than 300
lbs/ft x 2 ft or 600 lbs tension applied to it as the
cable exits the bend.

Sidewall Load

CABLE TYPE
300 V Nonshielded, 300 V and 600 V Shielded Control & Instrumentation
600 V Nonshielded Control & Instrumentation
600 V and 2400 V Nonshielded Power
5 kV-35 kV Shielded Power
Interlocked Armored Cable (all voltage)
CCW® MC-HL Armored Cable

SWBP (LBS/FT)
500
500
1000
1000
300
500

General Cable’s Approval List of Cable Pulling Lubricants
The following manufacturers, who are listed in the 2006 UL Electrical Construction Equipment Directory, provide wire pulling compounds intended for
use as lubricants in installing electrical conductors in raceways. These manufacturers have had some of their products evaluated by Underwriters
Laboratories (UL) to determine their compatibility with conductor insulation and coverings.
Since it is not feasible to test every possible combination of cable material with every wire pulling compound, the installer should check with the pulling
compound manufacturer or the cable manufacturer to determine compatibility between specific cable materials and the pulling compound.
The Listing Mark for these products includes the UL symbol, together with the word “LISTED,” a control number and the product name “Wire Pulling
Compound.” Refer to the latest edition of the UL Electrical Construction Equipment Directory for the current listing of manufacturers of wire pulling
compounds and their control numbers.
3M Company
American Bentonite International Inc.
American Polywater Corp.
Arnco Corp.
Dura-Line Corp.
Greenlee Textron
Ideal Industries Inc.*

J. C. Whitlam Mfg. Co.
Klein Tools Inc.
Madison Electric Products Inc.
Rainbow Technology Corp.
Rectorseal
Thomas & Betts Corp.

*Yellow 77 not recommended for use with UniShield® cables.

For LSZH jacketed cable, consult with pulling compound manufacturers.
Other wire pulling compounds may be suitable for use with General Cable constructions. Contact the wire pulling compound manufacturer regarding the
suitability of their products with specific General Cable products.

Phone: 888-593-3355
www.generalcable.com

SPEC F005
April, 2010

DC “HI-POT” Pre-Test Guidelines for MV Cables
The test voltage should be increased in steps of 10 kV, or minimum of 5 steps. The duration at each step
should be long enough for the current to reach a steady value (1 minute suggested). The test current will
momentarily increase for each voltage increment due to charging of the capacitance and the dielectric absorption
characteristics of the insulation. Stabilized current should be recorded at each step.
The maximum test voltage should be maintained for 15 minutes (new cable, shielded) / 5 minutes (nonshielded).
Leakage current should be recorded each minute after the maximum test voltage has been reached.
Increase of leakage current at any step may be an indication of a cable insulation problem. Failure of the cable or
cable accessories may result unless the voltage is rapidly reduced.
Otherwise, the leakage current should stabilize after about 5 minutes. Leakage current is essentially a function of
the construction and length of cable, but it can be influenced by the test conditions (wind and humidity) as well as
the test apparatus (leads).
Typical leakage currents in the order of 100 – 150 microamperes or higher are not unusual. A defective installation
is identified by increasing leakage current with time, at a fixed DC voltage.
All testing should be performed by qualified personnel taking all appropriate safety precautions.

Phone: 888-593-3355
www.generalcable.com

SPEC F025

April, 2010

DC “HI-POT” Testing Guidelines for MV Cables
DC High Potential (HI-POT) Testing of Medium-Voltage Power Cable
Overview
This procedure is intended to provide
general guidelines for high potential
DC testing of power cables.
All tests made after cable installation
and during the guarantee period
shall be made in accordance with
applicable specifications.
All safety precautions must be
observed during testing at
high voltage.
Read, understand and follow the
Operator’s Manual for the particular
test set being used!
Test Equipment
Direct current test equipment
is available commercially with a
wide range of voltages. Accessory
equipment necessary to safely
conduct high voltage tests—such as
safety barriers, rubber gloves and
nonconducting hard hats—must be
used; consult appropriate
safety officer.
Test Procedures
See IEEE Standard 400 Article 5
Direct Voltage Testing. Acceptable
procedures, although varying slightly
in technique, have more or less been
standardized as either a “withstand
test” or a “time-leaking current test.”

Phone: 888-593-3355
www.generalcable.com

Before performing any DC
over­potential tests:
•	All equipment must be
disconnected from the cable
circuit, i.e., taps, motors, circuit
breakers, surge arrestors, etc.
This will preclude damage to such
equipment and will prevent test
interruptions due to flashovers
and/or trip-outs resulting from
excessive leakage current.
•	Establish adequate clearance
between the circuit test ends and
any grounded object, and to other
equipment not under test (about
2.5 feet).
•	Ground all circuit conductors not
under test with all cable shields
including nearby equipment.
•	Consult termination manufacturers
for maximum test voltage
recommendations and
time limitations.
The direct current test voltage may
be applied either continuously or in
predetermined steps to the maximum
value in accordance with applicable
specifications.
•	Continuous Method – Apply
test voltage at an approximate
rise rate of 1 kV per second or
75% of the rated current output
of the equipment, whichever is
less. Some equipment will take
longer to reach the maximum test
voltage because of the amount of
charging current.
•	Step Method – Apply test voltage
slowly in 5 to 7 increments of
equal value to the maximum
specified. Allow sufficient time at
each stop for the leakage current
to stabilize.

HI-POT TESTING PROCEDURES
Normally this requires only a few
seconds unless cable circuits of high
capacitance are involved.
Record leakage current at each step.
Maintain the test voltage at
the prescribed value for the
time designated in applicable
specifications. The following times
are usually considered adequate. At
the end of the test period, set the
test set voltage control to zero, allow
the residual voltage on the circuit to
decay, then ground the conductor just
tested.
CAUTION
It should be recognized that DC
charges on cable can build up to
potentially dangerous levels if grounds
are removed too quickly. Maintain
solid grounds after the test on the
cable for at least 4 times the duration
of the test. On exceptionally long
cable lengths, it may be necessary
to increase the grounding time.
It is advantageous to maintain
these grounds longer and while
reconnecting circuit components.
•	Acceptance Testing – After
installation and before the cable
is placed in regular service, the
specified test voltage shall be
applied for 15 consecutive
minutes.
•	Proof Testing – At any time during
the period of guarantee, the cable
circuit may be removed from
service and tested at a reduced
voltage (normally 65 percent of the
original acceptance value) for 5
consecutive minutes.
•	Record the leakage current at one
minute intervals for the duration of
the test time involved.

SPEC F025

April, 2010

DC “HI-POT” Testing Guidelines for MV Cables
DC High Potential (HI-POT) Testing of Medium-Voltage Power Cable
Comments
The significance of conducting DC
high-voltage tests on nonshielded,
nonmetallic-sheathed cable is
dependent upon the environment
in which it is installed because the
characteristics of the return circuits
are unknown. The environment must
be carefully considered, or test results
may not be significant. In fact, these
tests can result in damage to the
cable insulation.
Humidity, condensation and actual
precipitation on the surface of a
cable termination can increase the
leakage current by several orders of
magnitude. Humidity also increases
the corona current, which indication is
included in the total leakage current.
Wind prevents the accumulation of
space charges at all bare energized
terminals.
This results in an increase of
corona. It is most desirable to
reduce or eliminate corona current
at the bare metal extremities of
cable or terminations. This may be
accomplished by covering these areas
with plastic envelopes, plastic or glass
containers, plastic wrap or suitable
electrical putty.

Routine periodic DC maintenance
testing of cable for the evaluation of
the insulation strength is not a common
practice. Some power cable users
have adopted a program of testing
circuits during planned outages,
preferring possible breakdowns during
testing rather than experiencing a
service outage. It is nearly impossible
to recommend test voltage values for
those maintenance tests with the history
of the cable circuit. An arbitrary test
voltage level could break down a cable
circuit that would otherwise render long
trouble-free service at normal operating
AC voltage.
The main usefulness of DC high-voltage
testing is to detect conducting particles
left on the creepage surface during
splicing or termination.
Test equipment should be supplied
from a stable, constant voltage
source. Do not use the same source
that is supplying arc welders or
other equipment causing line voltage
fluctuations. The output voltage of the
test set must be filtered and regulated.
Consider using a portable, motor-driven
alter­nator to energize the test set.

Testing Problems
Extra Leakage Current:
•	Failure to guard against corona
•	Failure to clean insulation surface
•	Failure to keep cable ends dry
•	Failure to provide adequate
clearance to ground
•	Improper shield termination
Erratic Readings:
•	Fluctuating voltage to test set
•	Improper test leads
Environmental Influences:
•	High relative humidity
•	Dampness, dew, fog
•	Wind, snow
Results vs. Cable Life
	 To date there is no basis for
correlation between DC test
results and cable life expectancy.

The gradual decrease or non-increase of
leakage current with respect to time at
maximum test voltage is the acceptance
criteria for DC HI-POT testing.

Phone: 888-593-3355
www.generalcable.com

SPEC F075

April, 2010

Field Electrical “HI-POT” Testing Guidelines
Acceptance Testing
	 Acceptance testing is performed to detect any defects in cable insulation and terminations which may have resulted from poor
workmanship or mechanical damage. This proof test confirms the integrity of the insulation and accessories before the cable is
placed into service.
	 After installation and before the cable is placed in regular service, the test voltages specified in the ICEA S-97-682 Table should
be applied for 15 consecutive minutes. Record the leakage current at one minute intervals for the duration of the test.

ICEA DC Field Test Voltages
ICEA S-97-682 Utility Shielded Power Cables Rated 5,000-46,000 Volts
Rated
Voltage Phaseto-Phase (kV)

5
8
15

Maximum DC Field
Test Voltages (kV)

Nominal Insulation Thickness
(Insulation Level)

Conductor Size

AWG/kcmil

mm

8 - 1000

100%

During or After
Installation

133%

2

mils

mm

mils

mm

8.4 - 507

90

2.29

115

2.92

> 1000

> 507

140

3.56

140

3.56

6 - 1000

13.3 - 507

115

2.92

140

3.56

> 1000

> 507

175

4.45

175

4.45

2 - 1000

33.6 - 507

175

4.45

> 1000

> 507

220

5.59

220

5.59

First 5 Years

100%

133%

100%

133%

28

36

9

11

36

44

11

14

56

64

18

20

25

1 - 2000

42.4 - 1013

260

6.60

320

8.13

80

96

25

30

28

1 - 2000

42.4 - 1013

280

7.11

345

8.76

84

100

26

31

35

1/0 - 2000

53.5 - 1013

345

8.76

420

10.7

100

124

31

39

46

4/0 - 2000

107.2 - 1013

445

11.3

580

14.7

132

172

41

54

DC test voltages are applied to discover gross problems such as improperly installed accessories or mechanical damage. DC testing is not expected to reveal deterioration due
to aging in service. There is some evidence that DC testing of aged cross-linked polyethylene cables can lead to early cable failures. Information on this subject is available in EPRI
project report TR-101245, “Effect of DC Testing in Extruding Cross-Linked Polyethylene Insulated Cables.”
Dimensions and weights are nominal; subject to industry tolerances.

Phone: 888-593-3355
www.generalcable.com

SPEC F100

January, 2010

Emergency Overload Current Guidelines
The increase or decrease of the load current is not associated with an instantaneous change of the cable
temperature. Hence, during emergency conditions, the cable may be overloaded for short periods of time at the
maximum overload temperature of 130°C/140°C for cable rated at 90°C/105˚C continuous.
Operations at the emergency overload temperature shall not exceed 1500 cumulative hours during the lifetime of
the cable. Lower temperature for emergency overload conditions may be required due to the type of material used
in the cable splices and terminations or environmental conditions.

Phone: 888-593-3355
www.generalcable.com

SPEC F125

January, 2010

Short Circuit Current Calculation Overview
The maximum short circuit current which is permitted to flow in the insulated conductor, or the metallic shielding
and bonding (grounding) components, is dependent on the duration of the short circuit and the material used in
the cable.

Insulated Conductors Formula
The graphs on the following pages show the short circuit capability of 10 AWG to 1000 kcmil, copper and
aluminum, XLPE and EPR insulated conductors for various periods of time. These graphs are in accordance with
ICEA publication P-32-382. The equations are based on the assumption that the duration of the short circuit is so
short that the heat generated is contained within the conductor, taking into consideration the temperature limit of
the insulation.
The graphs are derived from the following formula:

	
	

[ ]
[ ]

I
Copper Conductor	 —
A
I
Aluminum Conductor	 —
A

2

t = 0.0297 log10
2

t = 0.0125 log10

—— ]
[ —TT——++—234
234
—— ]
[ —TT——++—228
228
2
1

2
1

Which simplify to:
	

	
I =	 0.07195 A
Copper Conductor		
amperes for MV-90
		
t

	
=	 0.06773 A
Copper Conductor I		
amperes for MV-105
		
t
	
	Aluminum Conductor 		
amperes for MV-90
I =	 0.0470 A
		
t
	
	
Aluminum Conductor		
amperes for MV-105
I =	 0.044 A
		
t
	

Where:	 I	 =	
	
A	 =	
	
t	 =	
	T1	 =	
			
	T2	 =	

Phone: 888-593-3355
www.generalcable.com

Short circuit current (amperes)
Conductor cross-sectional area (circular mils)
Short circuit duration (seconds)
Maximum normal operating temperature, 90°C for MV-90 or 105°C
for MV-105
Maximum short circuit temperature, 250°C

SPEC F125

January, 2010

Short Circuit Currents

Allowable Short Circuit Currents For Thermoset Insulated Copper Conductors
Rated For 90°C Maximum Continuous Operation
1000000

Short Circuit Current—Amperes

100000

10000

Curves Based on the Formula

1000

2

234
[ ] t = 0.0297 log [ TT ++ 234
]
I
A

2

10

1

I	 =	Short Circuit Current–Amperes
A	 =	Conductor Area–Circular Mils
t	 =	Time of Short Circuit–Seconds
T1	=	Maximum Operating Temperature–90°C
T2	=	Maximum Short Circuit Temperature–250°C

100

10	8	6	4	2	
1	
1/0	
2/0	
3/0	
4/0	
250	
350	
500	
750	
1000

Conductor Size (AWG/kcmil)
1 Cycles
16 Cycles

2 Cycles
30 Cycles

4 Cycles
60 Cycles

8 Cycles
100 Cycles

Reference P-32-382-2007, reprinted in part with permission of ICEA. This excerpt is not intended to replace the standard in its entirety.
ICEA standards are subject to periodic review and revision. Complete texts of this and all ICEA standards are available at IHS.
Phone: 888-593-3355
www.generalcable.com

SPEC F125

January, 2010

Short Circuit Currents

Allowable Short Circuit Currents For Thermoset Insulated Copper Conductors
Rated For 105°C Maximum Continuous Operation
1000000

Short Circuit Current—Amperes

100000

10000

Curves Based on the Formula

1000

2

234
[ ] t = 0.0297 log [ TT ++ 234
]
I
A

2

10

1

I	 =	Short Circuit Current–Amperes
A	 =	Conductor Area–Circular Mils
t	 =	Time of Short Circuit–Seconds
T1	=	Maximum Operating Temperature–105°C
T2	=	Maximum Short Circuit Temperature–250°C

100

10	8	6	4	2	
1	
1/0	
2/0	
3/0	
4/0	
250	
350	
500	
750	
1000

Conductor Size (AWG/kcmil)
1 Cycles
16 Cycles

2 Cycles
30 Cycles

4 Cycles
60 Cycles

8 Cycles
100 Cycles

Reference P-32-382-2007, reprinted in part with permission of ICEA. This excerpt is not intended to replace the standard in its entirety.
ICEA standards are subject to periodic review and revision. Complete texts of this and all ICEA standards are available at IHS.
Phone: 888-593-3355
www.generalcable.com

SPEC F125

January, 2010

Short Circuit Currents

Allowable Short Circuit Currents For Thermoset Insulated Aluminum Conductors
Rated For 90°C Maximum Continuous Operation
1000000

Short Circuit Current—Amperes

100000

10000

Curves Based on the Formula

1000

2

228
[ ] t = 0.0125 log [ TT ++ 228
]
I
A

2

10

1

I	 =	Short Circuit Current–Amperes
A	 =	Conductor Area–Circular Mils
t	 =	Time of Short Circuit–Seconds
T1	=	Maximum Operating Temperature–90°C
T2	=	Maximum Short Circuit Temperature–250°C

100

10	8	6	4	2	
1	
1/0	
2/0	
3/0	
4/0	
250	
350	
500	
750	
1000

Conductor Size (AWG/kcmil)
1 Cycles
16 Cycles

2 Cycles
30 Cycles

4 Cycles
60 Cycles

8 Cycles
100 Cycles

Reference P-32-382-2007, reprinted in part with permission of ICEA. This excerpt is not intended to replace the standard in its entirety.
ICEA standards are subject to periodic review and revision. Complete texts of this and all ICEA standards are available at IHS.
Phone: 888-593-3355
www.generalcable.com

SPEC F125

January, 2010

Short Circuit Currents

Allowable Short Circuit Currents For Thermoset Insulated Aluminum Conductors
Rated For 105°C Maximum Continuous Operation
1000000

Short Circuit Current—Amperes

100000

10000

Curves Based on the Formula
1000
2

228
[ ] t = 0.0125 log [ TT ++ 228
]
I
A

2

10

1

I	 =	Short Circuit Current–Amperes
A	 =	Conductor Area–Circular Mils
t	 =	Time of Short Circuit–Seconds
T1	=	Maximum Operating Temperature–105°C
T2	=	Maximum Short Circuit Temperature–250°C

100

10	8	6	4	2	
1	
1/0	
2/0	
3/0	
4/0	
250	
350	
500	
750	
1000

Conductor Size (AWG/kcmil)
1 Cycles
16 Cycles

2 Cycles
30 Cycles

4 Cycles
60 Cycles

8 Cycles
100 Cycles

Reference P-32-382-2007, reprinted in part with permission of ICEA. This excerpt is not intended to replace the standard in its entirety.
ICEA standards are subject to periodic review and revision. Complete texts of this and all ICEA standards are available at IHS.
Phone: 888-593-3355
www.generalcable.com

SPEC F150

January, 2010

Short Circuit Current for Copper Shields
Formula—Short Circuit Current for Copper Shields
In the three conductor cables, a copper tape is applied over each extruded semi-conducting insulation shield with
a helical gap. Because the three copper tape shields are cabled in intimate contact with the bonding (grounding)
conductor, their combined total cross-sectional areas may be considered an integral shielding system for the purpose of calculating short circuit capacity. It is not possible however, to determine the contact resistance between
the components, due to possible oxides or film which may form on the components or movement of the cable
core during handling. It may be advisable to consider the short circuit capacity of the individual shields independently. Because the insulation shields are in thermal contact with the inner PVC jacket, the maximum short circuit
temperature T2 is 200°C. Refer to ICEA P-45-482, “Short Circuit Performance of Metallic Shields and Sheaths on
Insulated Cable,” for calculations involving cables that have other operating parameters.
M.A
_________
Under these temperature conditions the short circuit current formula is:
I=
amperes
t

		
TYPE OF SHIELD OR SHEATH	

FORMULA FOR
CALCULATING A

1. Wires applied either helically, as a braid or serving;
	 or longitudinally with corrugations 	
2. Helically applied tape, not overlapped	
3. Helically applied flat tape, overlapped	
	 	
4. Corrugated tape, longitudinally applied	
5. Tubular sheath	

Meaning of Symbols:	
A	 =	
	
B	 =	
	
b	 =	
	dis	 =	
	dm	 =	
	ds	 =	
	
I	 =	
	
w	 =	
	
n	 =	
	
L	 =	
	
t	 =	
	
M	 =	
			

nds2
1.27 nwb
4 bdm x

100
2(100-L)
1.27[π(dis+50)+B]b
4 bdm

Effective cross-sectional area, shield or sheath
Tape overlap (mils) (usually 375)
Thickness of tape (mils)
Diameter over semiconducting insulation shields (mils)
Mean diameter of shield or sheath (mils)
Diameter of wires (mils)
Short circuit current (amperes)
Width of tape (mils)
Number of serving or braid wires or tapes
Overlap of tape (percent)
Short circuit duration (seconds)
0.058 for 5-15 kV cables
0.060 for 25-46 kV cables

Phone: 888-593-3355
www.generalcable.com

SPEC F150

January, 2010

Formula – Short Circuit Currents for Copper Shields
Allowable Copper Shield Short Circuit Currents for 5–15 kV
100

Short Circuit Current—Kilo Amperes

10

1

0.1

.A
	0.058
I =	 _______
	
t
A=	Effective cross-sectional area (circular mils)
t=	 Short circuit duration (seconds)
I=	 Short circuit current (amperes)
Temperature excursion range 100°C–200°C
0.01

1

10

100

Effective Cross-Sectional Area in kcmil
1 Cycles
16 Cycles

Phone: 888-593-3355
www.generalcable.com

2 Cycles
30 Cycles

4 Cycles
60 Cycles

8 Cycles
100 Cycles

SPEC F150

January, 2010

Formula – Short Circuit Currents for Copper Shields
Allowable Copper Shield Short Circuit Currents for 25–46 kV

Short Circuit Current—Kilo Amperes

100

10

1

0.1

.A
	0.060
I =	 _______		
		
t
A=	Effective cross-sectional area (circular mils)
t=	 Short circuit duration (seconds)
I=	 Short circuit current (amperes)
Temperature excursion range 95°C–200°C

0.01

1

10

100

Effective Cross-Sectional Area in kcmil
1 Cycles
16 Cycles

2 Cycles
30 Cycles

4 Cycles
60 Cycles

8 Cycles
100 Cycles

Phone: 888-593-3355
www.generalcable.com

SPEC F175
June, 2013

AC Resistance & Inductive Reactance
AC Resistance ohms/km (at operating temperature)
CONDUCTOR
SIZE
AWG OR
kcmil

60°C

14
12
10
8
6

9.7550
6.1480
3.8680
2.4320
1.5300

10.2630
6.4660
4.0690
2.5580
1.6090

10.7550
6.7780
4.2650
2.6810
1.6870

—
10.6730
6.7010
4.2130
2.6520

4
3
2
1

.9614
.7630
.6055
.4797

1.0110
.8025
.6369
.5046

1.0600
.8412
.6676
.5289

1/0
2/0
3/0
4/0

.3803
.3018
.2393
.1898

.4000
.3174
.2517
.1997

250
300
350
400

.1613
.1346
.1157
.1015

500
600
750
1000

.0818
.0677
.0557
.0428

SINGLE STRANDED CONDUCTOR*
COPPER
75°C

3 CONDUCTOR CABLE**
ALUMINUM (ACM)

90°C

75°C

FACTOR
90°C

CU

AL

—
11.1880
7.0240
4.4160
2.7800

1.00
1.00
1.00
1.00
1.00

—
1.00
1.00
1.00
1.00

1.6670
1.3210
1.0480
.8313

1.7470
1.3850
1.0990
.8714

1.00
1.00
1.01
1.01

1.00
1.00
1.00
1.00

.4193
.3327
.2638
.2093

.6591
.5234
.4154
.3292

.6909
.5486
.4354
.3451

1.02
1.03
1.04
1.05

1.00
1.00
1.01
1.01

.1696
.1416
.1217
.1068

.1778
.1485
.1276
.1119

.2789
.2325
.1997
.1748

.2923
.2439
.2093
.1833

1.06
1.06
1.07
1.09

1.02
1.02
1.03
1.03

.0861
.0712
.0586
.0450

.0902
.0746
.0614
.0472

.1402
.1171
.0943
.0716

.1470
.1227
.0988
.0750

1.11
1.13
1.16
—

1.05
1.07
1.10
1.16

*Except for the most critical cases, these values may be used for 2 or 3 conductors in non-metallic or aluminum conduit.
**Multiply the single conductor values by these factors to determine the AC resistance of 3 conductor cable.
Impedance (Z, ohms/km) is obtained using the following formula: Z = √R2 + XL2 (neglecting capacitance).
R = AC Resistance ohm/km
Multiply ohms/km by 0.3048 to obtain ohms/1000 ft.
Dimensions and weights are nominal; subject to industry tolerance.

Inductive Reactance ohms/km (at 60 hertz) 600 Volt & 1000 Volt
CONDUCTOR
SIZE

VOLTAGE

3 SINGLE CABLES

3 CONDUCTOR CABLE

ONE CABLE DIAMETER SPACING

A

G	O

R	

B

kcmil

IN ALUMINUM

C
	VOLTS

A

B

ALUMINUM ARMOR* CONDUIT*

C

B

A

C

A

W

RW90

RA90

TECK90

RW90

AC9O, ACWU90

TECK90

14
12
10
8
6

600
600
600
1000
1000

—
—
—
—
—

—
—
—
—
—

—
—
—
—
—

.1480
.1395
.1315
.1455
.1370

.1230
.1160
.1095
.1225
.1140

.1230
.1155
.1090
.1145
.1175

4
3
2
1

1000
1000
1000
1000

—
—
—
—

—
—
—
—

—
—
—
—

.1290
.1255
.1230
.1280

.1075
.1045
.1025
.1065

.1105
.1070
.1045
.1060

1/0
2/0
3/0
4/0

1000
1000
1000
1000

.1695
.1660
.1650
.1630

.2040
.2010
.1970
.1960

.2190
.2140
.2130
.2080

.1200
.1165
.1135
.1110

.1000
.0970
.0945
.0925

.1020
.0995
.0965
.0945

250
300
350
400

1000
1000
1000
1000

.1620
.1600
.1595
.1570

.1925
.1895
.1875
.1875

.2085
.2045
.2010
.1990

.1105
.1085
.1070
.1055

.0920
.0905
.0895
.0880

.0950
.0930
.0915
.0910

500
600
750
1000

1000
1000
1000
1000

.1565
.1550
.1535
.1520

.1865
.1820
.1800
.1770

.1955
.1950
.1915
.1875

.1035
.1015
.1000
.0985

.0865
.0845
.0835
.0820

.0890
.0910
.0900
.0880

Note: Values shown are based on nominal cable dimensions, which are influenced by changes in materials and conductor design. Except for the most
critical cases, such variations are of little consequence.
Formula XL = 0.17362 log10 GMD ohms/km. XL = Inductive reactance ohms/km. GMD = Geometric mean distance between conductors. GMR = Geometric
GMR
mean radius of conductors.
For 3 conductors in steel conduit or steel armor, multiply table values by 1.25.
Multiply ohms/km by 0.3048 to obtain ohms/1000 ft.
Dimensions and weights are nominal; subject to industry tolerance.

Phone: 888-593-3355
www.generalcable.com

SPEC F175
June, 2013

AC Resistance & Inductive Reactance
Inductive Reactance ohms/km (at 60 hertz) 5 kV – TECK90 and HVTECK (Aluminum Armored)
CONDUCTOR
SIZE
AWG OR
kcmil

SINGLE CONDUCTOR
ONE CABLE DIAMETER SPACING

A

3 CONDUCTOR*

C

B

B

HVTECK SHIELDED

A

C
HVTECK SHIELDED

TECK 90
5 kV UNSHIELDED

5 kV (100%)

5 kV (133%)

TECK 90
5 kV UNSHIELDED

5 kV (100%)

5 kV (133%)

6
4
2
1

.2630
.2530
.2400
.2310

.2770
.2630
.2540
.2440

.2810
.2710
.2600
.2500

.1385
.1290
.1205
.1145

.1495
.1400
.1305
.1220

.1660
.1490
.1390
.1310

1/0
2/0
3/0
4/0

.2240
.2225
.2165
.2130

.2330
.2270
.2205
.2170

.2440
.2370
.2310
.2250

.1100
.1065
.1030
.1010

.1185
.1150
.1100
.1075

.1270
.1220
.1180
.1150

250
300
350
400

.2110
.2075
.2040
.2010

.2150
.2110
.2075
.2045

.2220
.2170
.2140
.2110

.1000
.0980
.0960
.0950

.1060
.1038
.1020
.1010

.1120
.1090
.1070
.1050

500
600
750
1000

.1980
.1970
.1935
.1895

.2015
.2000
.1975
.1920

.2090
.2030
.2010
.1960

.0925
.0945
.0935
.0910

.0980
.1010
.0990
.0955

.1040
.1060
.0980
.0950

Note: Values shown are based on nominal cable dimensions, which are influenced by changes in materials and conductor design. Except for the most
critical cases, such variations are of little consequence.
ohms/km. XL = Inductive reactance ohms/km. GMD = Geometric mean distance between conductors. GMR = Geometric mean
Formula XL = 0.17362 log10 GMD
GMR
radius of conductors.
For 3 conductors in steel conduit or steel armor, multiply table values by 1.25.
Multiply ohms/km by 0.3048 to obtain ohms/1000 ft.
Dimensions and weights are nominal; subject to industry tolerance.

Inductive Reactance ohms/km (at 60 hertz) 15 kV, 25 kV & 28 kV - HVTECK (Aluminum Armored)
CONDUCTOR
SIZE
AWG OR
kcmil

3 CONDUCTOR*

B

A

C

15 kV (100%)

15 kV (133%)

25 kV (100%)

25 kV (133%)

28 kV (100%)

28 kV (133%)

2
1

.1510
.1425

.1500

.1575

.1700

.1605

.1725

1/0
2/0
3/0
4/0

.1365
.1315
.1265
.1225

.1435
.1385
.1330
.1285

.1510
.1455
.1405
.1360

.1640
.1580
.1510
.1465

.1540
.1485
.1440
.1385

.1665
.1605
.1540
.1490

250
300
350
400

.1205
.1170
.1155
.1140

.1275
.1235
.1205
.1190

.1335
.1290
.1260
.1240

.1430
.1390
.1350
.1325

.1360
.1320
.1290
.1270

.1450
.1410
.1370
.1350

500
600
750
1000

.1105
.1100
.1080
.1045

.1150
.1155
.1120
-

.1200
.1205
-

-

.1220
-

-

Note: Values shown are based on nominal cable dimensions, which are influenced by changes in materials and conductor design. Except for the most
critical cases, such variations are of little consequence.
ohms/km. XL = Inductive reactance ohms/km. GMD = Geometric mean distance between conductors. GMR = Geometric mean
Formula XL = 0.17362 log10 GMD
GMR
radius of conductors.
For 3 conductors in steel conduit or steel armor, multiply table values by 1.25.
Multiply ohms/km by 0.3048 to obtain ohms/1000 ft.
Dimensions and weights are nominal; subject to industry tolerance.

Phone: 888-593-3355
www.generalcable.com

Index	Industrial

Catalog Number Index
CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

06591.210200.................. SPEC 5150
06591.215100.................. SPEC 5150
06591.215200.................. SPEC 5150
06591.215300.................. SPEC 5150
06591.215400.................. SPEC 5150
06591.216000.................. SPEC 5150
06591.216200.................. SPEC 5150
06591.216500.................. SPEC 5150
06591.217000.................. SPEC 5150
06591.217500.................. SPEC 5150
06790.047000.................. SPEC 4550
06790.077000.................. SPEC 4550
06790.086500.................. SPEC 4550
4775.03016...................... SPEC 4775
4775.03018...................... SPEC 4775
4775.04016...................... SPEC 4775
4775.04018...................... SPEC 4775
4775.05016...................... SPEC 4775
4775.05018...................... SPEC 4775
4775.07016...................... SPEC 4775
4775.07018...................... SPEC 4775
4775.09016...................... SPEC 4775
4775.09018...................... SPEC 4775
4775.12016...................... SPEC 4775
4775.12018...................... SPEC 4775
4775.16016...................... SPEC 4775
4775.16018...................... SPEC 4775
4775.19016...................... SPEC 4775
4775.19018...................... SPEC 4775
4775.25016...................... SPEC 4775
4775.25018...................... SPEC 4775
4775.30016...................... SPEC 4775
4775.30018...................... SPEC 4775
4775.37016...................... SPEC 4775
4775.37018...................... SPEC 4775
4780.03010...................... SPEC 4780
4780.03012...................... SPEC 4780
4780.03014...................... SPEC 4780
4780.04010...................... SPEC 4780
4780.04012...................... SPEC 4780
4780.04014...................... SPEC 4780
4780.05010...................... SPEC 4780
4780.05012...................... SPEC 4780
4780.05014...................... SPEC 4780
4780.07010...................... SPEC 4780
4780.07012...................... SPEC 4780
4780.07014...................... SPEC 4780
4780.09010...................... SPEC 4780
4780.09012...................... SPEC 4780
4780.09014...................... SPEC 4780
4780.12010...................... SPEC 4780
4780.12012...................... SPEC 4780
4780.12014...................... SPEC 4780
4780.19010...................... SPEC 4780
4780.19012...................... SPEC 4780
4780.19014...................... SPEC 4780
4780.25010...................... SPEC 4780
4780.25012...................... SPEC 4780
4780.25014...................... SPEC 4780
4780.30010...................... SPEC 4780
4780.30012...................... SPEC 4780
4780.30014...................... SPEC 4780
4780.37012...................... SPEC 4780
4780.37014...................... SPEC 4780
4785.03016...................... SPEC 4785
4785.03018...................... SPEC 4785
4785.04016...................... SPEC 4785
4785.04018...................... SPEC 4785
4785.05016...................... SPEC 4785
4785.05018...................... SPEC 4785
4785.07016...................... SPEC 4785
4785.07018...................... SPEC 4785
4785.09016...................... SPEC 4785

4785.09018...................... SPEC 4785
4785.12016...................... SPEC 4785
4785.12018...................... SPEC 4785
4785.19016...................... SPEC 4785
4785.19018...................... SPEC 4785
4785.25016...................... SPEC 4785
4785.25018...................... SPEC 4785
4785.30016...................... SPEC 4785
4785.30018...................... SPEC 4785
4785.37016...................... SPEC 4785
4785.37018...................... SPEC 4785
4790.03010...................... SPEC 4790
4790.03012...................... SPEC 4790
4790.03014...................... SPEC 4790
4790.04002...................... SPEC 4790
4790.04004...................... SPEC 4790
4790.04006...................... SPEC 4790
4790.04008...................... SPEC 4790
4790.04010...................... SPEC 4790
4790.04012...................... SPEC 4790
4790.04014...................... SPEC 4790
4790.05010...................... SPEC 4790
4790.05012...................... SPEC 4790
4790.05014...................... SPEC 4790
4790.07010...................... SPEC 4790
4790.07012...................... SPEC 4790
4790.07014...................... SPEC 4790
4790.09010...................... SPEC 4790
4790.09012...................... SPEC 4790
4790.09014...................... SPEC 4790
4790.12010...................... SPEC 4790
4790.12012...................... SPEC 4790
4790.12014...................... SPEC 4790
4790.19010...................... SPEC 4790
4790.19012...................... SPEC 4790
4790.19014...................... SPEC 4790
4790.25010...................... SPEC 4790
4790.25012...................... SPEC 4790
4790.25014...................... SPEC 4790
4790.30010...................... SPEC 4790
4790.30012...................... SPEC 4790
4790.30014...................... SPEC 4790
4790.37012...................... SPEC 4790
4790.37014...................... SPEC 4790
5125.001.......................... SPEC 5125
5125.002.......................... SPEC 5125
5125.004.......................... SPEC 5125
5125.006.......................... SPEC 5125
5125.008.......................... SPEC 5125
5125.010.......................... SPEC 5125
5125.012.......................... SPEC 5125
5125.014.......................... SPEC 5125
5125.110.......................... SPEC 5125
5125.210.......................... SPEC 5125
5125.250.......................... SPEC 5125
5125.310.......................... SPEC 5125
5125.350.......................... SPEC 5125
5125.410.......................... SPEC 5125
5125.500.......................... SPEC 5125
5125.600.......................... SPEC 5125
5125.750.......................... SPEC 5125
5175.001.......................... SPEC 5175
5175.002.......................... SPEC 5175
5175.004.......................... SPEC 5175
5175.006.......................... SPEC 5175
5175.008.......................... SPEC 5175
5175.110.......................... SPEC 5175
5175.210.......................... SPEC 5175
5175.250.......................... SPEC 5175
5175.310.......................... SPEC 5175
5175.350.......................... SPEC 5175
5175.410.......................... SPEC 5175
5175.500.......................... SPEC 5175

5175.600.......................... SPEC 5175
5175.750.......................... SPEC 5175
5310.01001...................... SPEC 5310
5310.01002...................... SPEC 5310
5310.01004...................... SPEC 5310
5310.01006...................... SPEC 5310
5310.01008...................... SPEC 5310
5310.01010...................... SPEC 5310
5310.01012...................... SPEC 5310
5310.01014...................... SPEC 5310
5310.01110...................... SPEC 5310
5310.01111...................... SPEC 5310
5310.01210...................... SPEC 5310
5310.01262...................... SPEC 5310
5310.01310...................... SPEC 5310
5310.01313...................... SPEC 5310
5310.01373...................... SPEC 5310
5310.01410...................... SPEC 5310
5310.01444...................... SPEC 5310
5310.01535...................... SPEC 5310
5310.01646...................... SPEC 5310
5310.01777...................... SPEC 5310
5310.01929...................... SPEC 5310
9025.16010001................ SPEC 9025
9025.16010002................ SPEC 9025
9025.16010003................ SPEC 9025
9025.16010004................ SPEC 9025
9050.20041221................ SPEC 9050
9050.20041222................ SPEC 9050
9050.20041223................ SPEC 9050
9050.20041224................ SPEC 9050
9050.20081221................ SPEC 9050
9050.20081222................ SPEC 9050
9050.20081223................ SPEC 9050
9050.20081224................ SPEC 9050
9050.20101221................ SPEC 9050
9050.20101222................ SPEC 9050
9050.20101223................ SPEC 9050
9050.20101224................ SPEC 9050
9050.20121221................ SPEC 9050
9050.20121222................ SPEC 9050
9050.20121223................ SPEC 9050
9050.20121224................ SPEC 9050
9050.20161221................ SPEC 9050
9050.20161222................ SPEC 9050
9050.20161223................ SPEC 9050
9050.20161224................ SPEC 9050
9050.20201221................ SPEC 9050
9050.20201222................ SPEC 9050
9050.20201223................ SPEC 9050
9050.20201224................ SPEC 9050
9050.20241221................ SPEC 9050
9050.20241222................ SPEC 9050
9050.20241223................ SPEC 9050
9050.20241224................ SPEC 9050
9050.20361221................ SPEC 9050
9050.20361222................ SPEC 9050
9050.20361223................ SPEC 9050
9050.20361224................ SPEC 9050
9050.20501221................ SPEC 9050
9050.20501222................ SPEC 9050
9050.20501223................ SPEC 9050
9050.20501224................ SPEC 9050
9075.20041221................ SPEC 9075
9075.20041222................ SPEC 9075
9075.20041223................ SPEC 9075
9075.20041224................ SPEC 9075
9075.20081221................ SPEC 9075
9075.20081222................ SPEC 9075
9075.20081223................ SPEC 9075
9075.20081224................ SPEC 9075
9075.20101221................ SPEC 9075
9075.20101222................ SPEC 9075

9075.20101223................ SPEC 9075
9075.20101224................ SPEC 9075
9075.20121221................ SPEC 9075
9075.20121222................ SPEC 9075
9075.20121223................ SPEC 9075
9075.20121224................ SPEC 9075
9075.20161221................ SPEC 9075
9075.20161222................ SPEC 9075
9075.20161223................ SPEC 9075
9075.20161224................ SPEC 9075
9075.20201221................ SPEC 9075
9075.20201222................ SPEC 9075
9075.20201223................ SPEC 9075
9075.20201224................ SPEC 9075
9075.20241221................ SPEC 9075
9075.20241222................ SPEC 9075
9075.20241223................ SPEC 9075
9075.20241224................ SPEC 9075
9075.20361221................ SPEC 9075
9075.20361222................ SPEC 9075
9075.20361223................ SPEC 9075
9075.20361224................ SPEC 9075
9075.20501221................ SPEC 9075
9075.20501222................ SPEC 9075
9075.20501223................ SPEC 9075
9075.20501224................ SPEC 9075
9125.16010001................ SPEC 9125
9125.16010002................ SPEC 9125
9125.16021201................ SPEC 9125
9125.16021202................ SPEC 9125
9125.16041201................ SPEC 9125
9125.16041202................ SPEC 9125
9125.16081201................ SPEC 9125
9125.16081202................ SPEC 9125
9125.16121201................ SPEC 9125
9125.16121202................ SPEC 9125
9125.16161201................ SPEC 9125
9125.16161202................ SPEC 9125
9125.16241201................ SPEC 9125
9125.16241202................ SPEC 9125
9125.16361201................ SPEC 9125
9125.16361202................ SPEC 9125
9125.16501201................ SPEC 9125
9125.16501202................ SPEC 9125
9150.16010001................ SPEC 9150
9150.16010002................ SPEC 9150
9150.16021201................ SPEC 9150
9150.16021202................ SPEC 9150
9150.16041201................ SPEC 9150
9150.16041202................ SPEC 9150
9150.16081201................ SPEC 9150
9150.16081202................ SPEC 9150
9150.16121201................ SPEC 9150
9150.16121202................ SPEC 9150
9150.16161201................ SPEC 9150
9150.16161202................ SPEC 9150
9150.16241201................ SPEC 9150
9150.16241202................ SPEC 9150
9150.16361201................ SPEC 9150
9150.16361202................ SPEC 9150
9150.16501201................ SPEC 9150
9150.16501202................ SPEC 9150
9225.16010001................ SPEC 9225
9225.16010002................ SPEC 9225
9225.16021221................ SPEC 9225
9225.16041221................ SPEC 9225
9225.16041222................ SPEC 9225
9225.16061221................ SPEC 9225
9225.16081221................ SPEC 9225
9225.16081222................ SPEC 9225
9225.16101221................ SPEC 9225
9225.16121221................ SPEC 9225
9225.16121222................ SPEC 9225

Phone: 888-593-3355
www.generalcable.com

Industrial	Index

Catalog Number Index
CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

9225.16161221................ SPEC 9225
9225.16161222................ SPEC 9225
9225.16201221................ SPEC 9225
9225.16241221................ SPEC 9225
9225.16241222................ SPEC 9225
9225.16361221................ SPEC 9225
9225.16361222................ SPEC 9225
9225.16501221................ SPEC 9225
9225.18021221................ SPEC 9225
9225.18041221................ SPEC 9225
9225.18041222................ SPEC 9225
9225.18061221................ SPEC 9225
9225.18081221................ SPEC 9225
9225.18081222................ SPEC 9225
9225.18101221................ SPEC 9225
9225.18121221................ SPEC 9225
9225.18121222................ SPEC 9225
9225.18161221................ SPEC 9225
9225.18161222................ SPEC 9225
9225.18201221................ SPEC 9225
9225.18241221................ SPEC 9225
9225.18241222................ SPEC 9225
9225.18361221................ SPEC 9225
9225.18361222................ SPEC 9225
9225.18501221................ SPEC 9225
9225.20021221................ SPEC 9225
9225.20041221................ SPEC 9225
9225.20041222................ SPEC 9225
9225.20061221................ SPEC 9225
9225.20081221................ SPEC 9225
9225.20081222................ SPEC 9225
9225.20101221................ SPEC 9225
9225.20121221................ SPEC 9225
9225.20121222................ SPEC 9225
9225.20161221................ SPEC 9225
9225.20161222................ SPEC 9225
9225.20201221................ SPEC 9225
9225.20241221................ SPEC 9225
9225.20241222................ SPEC 9225
9225.20361221................ SPEC 9225
9225.20361222................ SPEC 9225
9225.20501221................ SPEC 9225
9250.16021221................ SPEC 9250
9250.16041221................ SPEC 9250
9250.16041222................ SPEC 9250
9250.16061221................ SPEC 9250
9250.16081221................ SPEC 9250
9250.16081222................ SPEC 9250
9250.16101221................ SPEC 9250
9250.16121221................ SPEC 9250
9250.16121222................ SPEC 9250
9250.16161221................ SPEC 9250
9250.16161222................ SPEC 9250
9250.16201221................ SPEC 9250
9250.16241221................ SPEC 9250
9250.16241222................ SPEC 9250
9250.16361221................ SPEC 9250
9250.16361222................ SPEC 9250
9250.16501221................ SPEC 9250
9250.18021221................ SPEC 9250
9250.18041221................ SPEC 9250
9250.18041222................ SPEC 9250
9250.18061221................ SPEC 9250
9250.18081221................ SPEC 9250
9250.18081222................ SPEC 9250
9250.18101221................ SPEC 9250
9250.18121221................ SPEC 9250
9250.18121222................ SPEC 9250
9250.18161221................ SPEC 9250
9250.18161222................ SPEC 9250
9250.18201221................ SPEC 9250
9250.18241221................ SPEC 9250
9250.18241222................ SPEC 9250

9250.18361221................ SPEC 9250
9250.18361222................ SPEC 9250
9250.18501221................ SPEC 9250
9250.20021221................ SPEC 9250
9250.20041221................ SPEC 9250
9250.20041222................ SPEC 9250
9250.20061221................ SPEC 9250
9250.20081221................ SPEC 9250
9250.20081222................ SPEC 9250
9250.20101221................ SPEC 9250
9250.20121221................ SPEC 9250
9250.20121222................ SPEC 9250
9250.20161221................ SPEC 9250
9250.20161222................ SPEC 9250
9250.20201221................ SPEC 9250
9250.20241221................ SPEC 9250
9250.20241222................ SPEC 9250
9250.20361221................ SPEC 9250
9250.20361222................ SPEC 9250
9250.20501221................ SPEC 9250
9325.16010001................ SPEC 9325
9325.16010002................ SPEC 9325
9325.16020001................ SPEC 9325
9325.16040001................ SPEC 9325
9325.16040002................ SPEC 9325
9325.16060001................ SPEC 9325
9325.16080001................ SPEC 9325
9325.16080002................ SPEC 9325
9325.16100001................ SPEC 9325
9325.16120001................ SPEC 9325
9325.16120002................ SPEC 9325
9325.16160001................ SPEC 9325
9325.16160002................ SPEC 9325
9325.16200001................ SPEC 9325
9325.16240001................ SPEC 9325
9325.16240002................ SPEC 9325
9325.16360001................ SPEC 9325
9325.16360002................ SPEC 9325
9325.16500001................ SPEC 9325
9325.18020001................ SPEC 9325
9325.18040001................ SPEC 9325
9325.18080001................ SPEC 9325
9325.18120001................ SPEC 9325
9325.18160001................ SPEC 9325
9325.18240001................ SPEC 9325
9350.16020001................ SPEC 9350
9350.16040001................ SPEC 9350
9350.16040002................ SPEC 9350
9350.16060001................ SPEC 9350
9350.16080001................ SPEC 9350
9350.16080002................ SPEC 9350
9350.16100001................ SPEC 9350
9350.16120001................ SPEC 9350
9350.16120002................ SPEC 9350
9350.16160001................ SPEC 9350
9350.16160002................ SPEC 9350
9350.16200001................ SPEC 9350
9350.16240001................ SPEC 9350
9350.16240002................ SPEC 9350
9350.16360001................ SPEC 9350
9350.16360002................ SPEC 9350
9350.16500001................ SPEC 9350
9350.18020001................ SPEC 9350
9350.18040001................ SPEC 9350
9350.18080001................ SPEC 9350
9350.18120001................ SPEC 9350
9350.18160001................ SPEC 9350
9350.18240001................ SPEC 9350
9500.01002110................ SPEC 9500
9500.01003110................ SPEC 9500
9500.01004110................ SPEC 9500
9500.01006110................ SPEC 9500
9500.01008110................ SPEC 9500

9500.01011110................ SPEC 9500
9500.01202112................ SPEC 9500
9500.01203112................ SPEC 9500
9500.01204112................ SPEC 9500
9500.01205112................ SPEC 9500
9500.01206112................ SPEC 9500
9500.01208112................ SPEC 9500
9500.01211112................ SPEC 9500
9500.01218112................ SPEC 9500
9500.01236112................ SPEC 9500
9500.01402114................ SPEC 9500
9500.01403114................ SPEC 9500
9500.01404114................ SPEC 9500
9500.01405114................ SPEC 9500
9500.01406114................ SPEC 9500
9500.01408114................ SPEC 9500
9500.01411114................ SPEC 9500
9500.01418114................ SPEC 9500
9500.01436114................ SPEC 9500
9510.01004110................ SPEC 9510
9510.01204112................ SPEC 9510
9510.01205112................ SPEC 9510
9510.01207112................ SPEC 9510
9510.01209112................ SPEC 9510
9510.01404114................ SPEC 9510
9510.01405114................ SPEC 9510
9510.01407114................ SPEC 9510
9510.01409114................ SPEC 9510
9510.01412114................ SPEC 9510
9510.01419114................ SPEC 9510
9510.01437114................ SPEC 9510
9510.012121112.............. SPEC 9510
9525.01002000................ SPEC 9525
9525.01003000................ SPEC 9525
9525.01004000................ SPEC 9525
9525.01005000................ SPEC 9525
9525.01007000................ SPEC 9525
9525.01009000................ SPEC 9525
9525.01012000................ SPEC 9525
9525.01202000................ SPEC 9525
9525.01203000................ SPEC 9525
9525.01204000................ SPEC 9525
9525.01205000................ SPEC 9525
9525.01207000................ SPEC 9525
9525.01209000................ SPEC 9525
9525.01212000................ SPEC 9525
9525.01219000................ SPEC 9525
9525.01237000................ SPEC 9525
9525.01402000................ SPEC 9525
9525.01403000................ SPEC 9525
9525.01404000................ SPEC 9525
9525.01405000................ SPEC 9525
9525.01407000................ SPEC 9525
9525.01409000................ SPEC 9525
9525.01412000................ SPEC 9525
9525.01419000................ SPEC 9525
9525.01437000................ SPEC 9525
9600.00103310................ SPEC 9600
9600.00104106................ SPEC 9600
9600.00203310................ SPEC 9600
9600.00204106................ SPEC 9600
9600.00403312................ SPEC 9600
9600.00404108................ SPEC 9600
9600.00603312................ SPEC 9600
9600.00604108................ SPEC 9600
9600.00803314................ SPEC 9600
9600.00804110................ SPEC 9600
9600.01003314................ SPEC 9600
9600.01004314................ SPEC 9600
9600.01203316................ SPEC 9600
9600.01204316................ SPEC 9600
9600.01403318................ SPEC 9600
9600.01404318................ SPEC 9600

9600.11003310................ SPEC 9600
9600.11004106................ SPEC 9600
9600.21003310................ SPEC 9600
9600.21004106................ SPEC 9600
9600.25003308................ SPEC 9600
9600.25004104................ SPEC 9600
9600.31003308................ SPEC 9600
9600.31004104................ SPEC 9600
9600.35003307................ SPEC 9600
9600.35004103................ SPEC 9600
9600.41003308................ SPEC 9600
9600.41004104................ SPEC 9600
9600.50003306................ SPEC 9600
9600.50004102................ SPEC 9600
9600.75003305................ SPEC 9600
9600.75004101................ SPEC 9600
9600.100031110.............. SPEC 9600
9600.100041110.............. SPEC 9600
9615.00103310................ SPEC 9615
9615.00203310................ SPEC 9615
9615.00403312................ SPEC 9615
9615.00603312................ SPEC 9615
9615.00803314................ SPEC 9615
9615.01003314................ SPEC 9615
9615.01203316................ SPEC 9615
9615.01403318................ SPEC 9615
9615.11003310................ SPEC 9615
9615.21003306................ SPEC 9615
9615.25003304................ SPEC 9615
9615.35003302................ SPEC 9615
9615.41003304................ SPEC 9615
9615.50003301................ SPEC 9615
9625.043124108.............. SPEC 9625
9625.063124108.............. SPEC 9625
9625.083124110.............. SPEC 9625
9625.103124110.............. SPEC 9625
9650.023123000.............. SPEC 9650
9650.023124000.............. SPEC 9650
9650.023143000.............. SPEC 9650
9650.023144000.............. SPEC 9650
9650.024123000.............. SPEC 9650
9650.024124000.............. SPEC 9650
9650.024143000.............. SPEC 9650
9650.024144000.............. SPEC 9650
9650.043123000.............. SPEC 9650
9650.043124000.............. SPEC 9650
9650.043143000.............. SPEC 9650
9650.043144000.............. SPEC 9650
9650.044123000.............. SPEC 9650
9650.044124000.............. SPEC 9650
9650.044143000.............. SPEC 9650
9650.044144000.............. SPEC 9650
9650.063123000.............. SPEC 9650
9650.063124000.............. SPEC 9650
9650.063143000.............. SPEC 9650
9650.063144000.............. SPEC 9650
9650.064123000.............. SPEC 9650
9650.064124000.............. SPEC 9650
9650.064143000.............. SPEC 9650
9650.064144000.............. SPEC 9650
9650.083123000.............. SPEC 9650
9650.083124000.............. SPEC 9650
9650.083143000.............. SPEC 9650
9650.083144000.............. SPEC 9650
9650.084123000.............. SPEC 9650
9650.084124000.............. SPEC 9650
9650.084143000.............. SPEC 9650
9650.084144000.............. SPEC 9650
9650.103123000.............. SPEC 9650
9650.103143000.............. SPEC 9650
9650.103144000.............. SPEC 9650
9650.104123000.............. SPEC 9650
9650.104124000.............. SPEC 9650

Phone: 888-593-3355
www.generalcable.com

Index	Industrial

Catalog Number Index
CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

9650.104143000.............. SPEC 9650
9650.104144000.............. SPEC 9650
9650.123143000.............. SPEC 9650
9650.123144000.............. SPEC 9650
9650.124143000.............. SPEC 9650
9650.124144000.............. SPEC 9650
9675.00103310................ SPEC 9675
9675.00203310................ SPEC 9675
9675.00403312................ SPEC 9675
9675.00603312................ SPEC 9675
9675.00803314................ SPEC 9675
9675.01003316................ SPEC 9675
9675.01203318................ SPEC 9675
9675.11003310................ SPEC 9675
9675.21003310................ SPEC 9675
9675.25003308................ SPEC 9675
9675.35003308................ SPEC 9675
9675.41003308................ SPEC 9675
9675.50003306................ SPEC 9675
9700.00103308................ SPEC 9700
9700.00203310................ SPEC 9700
9700.00403310................ SPEC 9700
9700.00603310................ SPEC 9700
9700.00803312................ SPEC 9700
9700.10003304................ SPEC 9700
9700.11003308................ SPEC 9700
9700.21003308................ SPEC 9700
9700.25003307................ SPEC 9700
9700.35003306................ SPEC 9700
9700.41003307................ SPEC 9700
9700.50003305................ SPEC 9700
9700.75003304................ SPEC 9700
9800.00103308................ SPEC 9800
9800.00203310................ SPEC 9800
9800.00403310................ SPEC 9800
9800.00603310................ SPEC 9800
9800.10003304................ SPEC 9800
9800.11003308................ SPEC 9800
9800.21003308................ SPEC 9800
9800.25003306................ SPEC 9800
9800.35003306................ SPEC 9800
9800.41003307................ SPEC 9800
9800.50003305................ SPEC 9800
9800.75003304................ SPEC 9800
9815.00103308................ SPEC 9815
9815.00203310................ SPEC 9815
9815.00403310................ SPEC 9815
9815.00603310................ SPEC 9815
9815.10003304................ SPEC 9815
9815.11003308................ SPEC 9815
9815.21003308................ SPEC 9815
9815.25003306................ SPEC 9815
9815.35003306................ SPEC 9815
9815.41003307................ SPEC 9815
9815.50003305................ SPEC 9815
9815.75003304................ SPEC 9815
9825.00103104................ SPEC 9825
9825.00203106................ SPEC 9825
9825.11003104................ SPEC 9825
9825.21003104................ SPEC 9825
9825.25003102................ SPEC 9825
9825.35003102................ SPEC 9825
9825.41003103................ SPEC 9825
9825.50003101................ SPEC 9825
9825.750031110.............. SPEC 9825
9835.00103104................ SPEC 9835
9835.00203106................ SPEC 9835
9835.11003104................ SPEC 9835
9835.21003104................ SPEC 9835
9835.25003102................ SPEC 9835
9835.35003102................ SPEC 9835
9835.41003103................ SPEC 9835
9835.50003101................ SPEC 9835

9835.750031110.............. SPEC 9835
9845.00103104................ SPEC 9845
9845.11003104................ SPEC 9845
9845.21003104................ SPEC 9845
9845.25003102................ SPEC 9845
9845.35003102................ SPEC 9845
9845.41003103................ SPEC 9845
9845.50003101................ SPEC 9845
9855.00103104................ SPEC 9855
9855.11003104................ SPEC 9855
9855.21003104................ SPEC 9855
9855.25003103................ SPEC 9855
9855.35003102................ SPEC 9855
9855.41003103................ SPEC 9855
9855.50003101................ SPEC 9855
9875.11003104................ SPEC 9875
9875.21003104................ SPEC 9875
9875.25003103................ SPEC 9875
9875.35003102................ SPEC 9875
9875.41003103................ SPEC 9875
9875.50003101................ SPEC 9875
9900.15744...................... SPEC 9900
9900.27901...................... SPEC 9900
9900.KS226...................... SPEC 9900
9900.PS526...................... SPEC 9900
11206.332083.................. SPEC 8125
11281.015400.................. SPEC 8700
11281.016000.................. SPEC 8700
11281.016200.................. SPEC 8700
11281.016500.................. SPEC 8700
11281.016700.................. SPEC 8700
11281.017000.................. SPEC 8700
11281.017500.................. SPEC 8700
11281.030100.................. SPEC 8750
11281.030200.................. SPEC 8750
11281.030400.................. SPEC 8750
11281.030600.................. SPEC 8750
11281.035100.................. SPEC 8750
11281.035200.................. SPEC 8750
11281.035300.................. SPEC 8750
11281.035400.................. SPEC 8750
11281.036000.................. SPEC 8750
11281.036200.................. SPEC 8750
11281.036500.................. SPEC 8750
11281.036700.................. SPEC 8750
11281.037000.................. SPEC 8750
11281.040100.................. SPEC 8775
11281.040200.................. SPEC 8775
11281.045100.................. SPEC 8775
11281.045200.................. SPEC 8775
11281.045300.................. SPEC 8775
11281.045400.................. SPEC 8775
11281.046000.................. SPEC 8775
11281.046200.................. SPEC 8775
11281.046500.................. SPEC 8775
11281.046700.................. SPEC 8775
11281.047000.................. SPEC 8775
11288.010100.................. SPEC 8150
11288.010200.................. SPEC 8150
11288.010300.................. SPEC 8150
11288.010400.................. SPEC 8150
11288.010600.................. SPEC 8150
11288.015100.................. SPEC 8150
11288.015200.................. SPEC 8150
11288.015300.................. SPEC 8150
11288.015400.................. SPEC 8150
11288.016000.................. SPEC 8150
11288.016200.................. SPEC 8150
11288.016500.................. SPEC 8150
11288.017000.................. SPEC 8150
11288.017500.................. SPEC 8150
11288.020100.................. SPEC 8125
11288.020200.................. SPEC 8175

11288.020300.................. SPEC 8175
11288.020400.................. SPEC 8175
11288.025100.................. SPEC 8175
11288.025200.................. SPEC 8175
11288.025300.................. SPEC 8175
11288.025400.................. SPEC 8100
11288.026000.................. SPEC 8100
11288.026200.................. SPEC 8175
11288.026500.................. SPEC 8100
11288.027000.................. SPEC 8100
11288.027500.................. SPEC 8100
11288.030300.................. SPEC 8100
11288.030600.................. SPEC 8175
11288.035100.................. SPEC 8100
11288.035200.................. SPEC 8100
11288.035300.................. SPEC 8100
11288.036200.................. SPEC 8100
11288.036500.................. SPEC 8175
11288.037500.................. SPEC 8175
11288.040100.................. SPEC 8175
11288.040200.................. SPEC 8125
11288.040400.................. SPEC 8125
11288.040600.................. SPEC 8100
11288.045100.................. SPEC 8125
11288.045200.................. SPEC 8125
11288.045300.................. SPEC 8125
11288.045400.................. SPEC 8175
11288.046000.................. SPEC 8175
11288.050100.................. SPEC 8100
11288.050200.................. SPEC 8100
11288.050400.................. SPEC 8100
11288.057000.................. SPEC 8175
11288.145400.................. SPEC 8125
11288.210100.................. SPEC 8200
11288.210200.................. SPEC 8200
11288.210400.................. SPEC 8200
11288.210600.................. SPEC 8200
11288.215100.................. SPEC 8200
11288.215200.................. SPEC 8200
11288.215300.................. SPEC 8200
11288.215400.................. SPEC 8200
11288.220300.................. SPEC 8125
11288.226000.................. SPEC 8125
11288.226200.................. SPEC 8125
11288.226500.................. SPEC 8125
11288.227000.................. SPEC 8125
11288.227500.................. SPEC 8125
11289.415100.................. SPEC 8550
11289.415200.................. SPEC 8550
11289.415300.................. SPEC 8550
11289.415400.................. SPEC 8550
11289.416000.................. SPEC 8550
11289.416200.................. SPEC 8550
11289.416500.................. SPEC 8550
11289.417000.................. SPEC 8550
11289.417500.................. SPEC 8550
11298.030100.................. SPEC 7100
11298.030200.................. SPEC 7100
11298.030400.................. SPEC 7100
11298.030600.................. SPEC 7100
11298.035100.................. SPEC 7100
11298.035200.................. SPEC 7100
11298.035300.................. SPEC 7100
11298.035400.................. SPEC 7100
11298.036000.................. SPEC 7150
11298.036200.................. SPEC 7150
11298.036500.................. SPEC 7150
11298.037000.................. SPEC 7150
11298.037500.................. SPEC 7150
11298.040100.................. SPEC 7100
11298.040200.................. SPEC 7100
11298.040400.................. SPEC 7100
11298.040600.................. SPEC 7100

11298.045100.................. SPEC 7100
11298.045200.................. SPEC 7100
11298.045300.................. SPEC 7100
11298.045400.................. SPEC 7100
11298.046000.................. SPEC 7150
11298.046200.................. SPEC 7150
11298.046500.................. SPEC 7150
11298.047000.................. SPEC 7150
11298.047500.................. SPEC 7150
11298.515100.................. SPEC 7160
11298.515200.................. SPEC 7160
11298.515300.................. SPEC 7160
11298.515400.................. SPEC 7160
11298.516000.................. SPEC 7160
11298.516200.................. SPEC 7160
11298.516500.................. SPEC 7160
11298.517000.................. SPEC 7160
11298.517500.................. SPEC 7160
12211.710100.................. SPEC 5800
12211.710100A..............SPEC 5800A
12211.710200.................. SPEC 5800
12211.710200A..............SPEC 5800A
12211.710400.................. SPEC 5800
12211.710400A..............SPEC 5800A
12211.710600.................. SPEC 5800
12211.710600A..............SPEC 5800A
12211.710800.................. SPEC 5800
12211.710800A..............SPEC 5800A
12211.711100.................. SPEC 5800
12211.711200.................. SPEC 5800
12211.711400.................. SPEC 5800
12211.715100.................. SPEC 5800
12211.715100A..............SPEC 5800A
12211.715200.................. SPEC 5800
12211.715200A..............SPEC 5800A
12211.715300.................. SPEC 5800
12211.715300A..............SPEC 5800A
12211.715400.................. SPEC 5800
12211.715400A..............SPEC 5800A
12211.716250.................. SPEC 5800
12211.716250A..............SPEC 5800A
12211.716300.................. SPEC 5800
12211.716300A..............SPEC 5800A
12211.716350.................. SPEC 5800
12211.716350A..............SPEC 5800A
12211.716400.................. SPEC 5800
12211.716400A..............SPEC 5800A
12211.716500.................. SPEC 5800
12211.716500A..............SPEC 5800A
12211.716600.................. SPEC 5800
12211.716600A..............SPEC 5800A
12211.716750.................. SPEC 5800
12211.716750A..............SPEC 5800A
12211.717000.................. SPEC 5800
12211.717000A..............SPEC 5800A
12221.710100.................. SPEC 5810
12221.710100A..............SPEC 5810A
12221.710200.................. SPEC 5810
12221.710200A..............SPEC 5810A
12221.710400.................. SPEC 5810
12221.710400A..............SPEC 5810A
12221.710600.................. SPEC 5810
12221.710600A..............SPEC 5810A
12221.710800.................. SPEC 5810
12221.710800A..............SPEC 5810A
12221.711100.................. SPEC 5810
12221.711200.................. SPEC 5810
12221.711400.................. SPEC 5810
12221.715100.................. SPEC 5810
12221.715100A..............SPEC 5810A
12221.715200.................. SPEC 5810
12221.715200A..............SPEC 5810A
12221.715300.................. SPEC 5810

Phone: 888-593-3355
www.generalcable.com

Industrial	Index

Catalog Number Index
CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

12221.715300A..............SPEC 5810A
12221.715400.................. SPEC 5810
12221.715400A..............SPEC 5810A
12221.716250.................. SPEC 5810
12221.716250A..............SPEC 5810A
12221.716300.................. SPEC 5810
12221.716300A..............SPEC 5810A
12221.716350.................. SPEC 5810
12221.716350A..............SPEC 5810A
12221.716400.................. SPEC 5810
12221.716400A..............SPEC 5810A
12221.716500.................. SPEC 5810
12221.716500A..............SPEC 5810A
12221.716600.................. SPEC 5810
12221.716600A..............SPEC 5810A
12221.716750.................. SPEC 5810
12221.716750A..............SPEC 5810A
12221.717000.................. SPEC 5810
12221.717000A..............SPEC 5810A
12411.710100.................. SPEC 5840
12411.710100A..............SPEC 5840A
12411.710200.................. SPEC 5840
12411.710200A..............SPEC 5840A
12411.710400.................. SPEC 5840
12411.710400A..............SPEC 5840A
12411.710600.................. SPEC 5840
12411.710600A..............SPEC 5840A
12411.710800.................. SPEC 5840
12411.710800A..............SPEC 5840A
12411.711100.................. SPEC 5840
12411.711200.................. SPEC 5840
12411.711400.................. SPEC 5840
12411.711600.................. SPEC 5840
12411.711800.................. SPEC 5840
12411.715100.................. SPEC 5840
12411.715100A..............SPEC 5840A
12411.715200.................. SPEC 5840
12411.715200A..............SPEC 5840A
12411.715300.................. SPEC 5840
12411.715300A..............SPEC 5840A
12411.715400.................. SPEC 5840
12411.715400A..............SPEC 5840A
12411.716250.................. SPEC 5840
12411.716250A..............SPEC 5840A
12411.716300.................. SPEC 5840
12411.716300A..............SPEC 5840A
12411.716350.................. SPEC 5840
12411.716350A..............SPEC 5840A
12411.716400.................. SPEC 5840
12411.716400A..............SPEC 5840A
12411.716500.................. SPEC 5840
12411.716500A..............SPEC 5840A
12411.716600.................. SPEC 5840
12411.716600A..............SPEC 5840A
12411.716750.................. SPEC 5840
12411.716750A..............SPEC 5840A
12411.717000.................. SPEC 5840
12411.717000A..............SPEC 5840A
12421.710100.................. SPEC 5850
12421.710100A..............SPEC 5850A
12421.710200.................. SPEC 5850
12421.710200A..............SPEC 5850A
12421.710400.................. SPEC 5850
12421.710400A..............SPEC 5850A
12421.710600.................. SPEC 5850
12421.710600A..............SPEC 5850A
12421.710800.................. SPEC 5850
12421.710800A..............SPEC 5850A
12421.711100.................. SPEC 5850
12421.711200.................. SPEC 5850
12421.711400.................. SPEC 5850
12421.711600.................. SPEC 5850
12421.711800.................. SPEC 5850

12421.715100.................. SPEC 5850
12421.715100A..............SPEC 5850A
12421.715200.................. SPEC 5850
12421.715200A..............SPEC 5850A
12421.715300.................. SPEC 5850
12421.715300A..............SPEC 5850A
12421.715400.................. SPEC 5850
12421.715400A..............SPEC 5850A
12421.716250.................. SPEC 5850
12421.716250A..............SPEC 5850A
12421.716300.................. SPEC 5850
12421.716300A..............SPEC 5850A
12421.716350.................. SPEC 5850
12421.716350A..............SPEC 5850A
12421.716400.................. SPEC 5850
12421.716400A..............SPEC 5850A
12421.716500.................. SPEC 5850
12421.716500A..............SPEC 5850A
12421.716600.................. SPEC 5850
12421.716600A..............SPEC 5850A
12421.716750.................. SPEC 5850
12421.716750A..............SPEC 5850A
12421.717000.................. SPEC 5850
12421.717000A..............SPEC 5850A
12431.710100.................. SPEC 5845
12431.710200.................. SPEC 5845
12431.710400.................. SPEC 5845
12431.710600.................. SPEC 5845
12431.710800.................. SPEC 5845
12431.711100.................. SPEC 5845
12431.711200.................. SPEC 5845
12431.711400.................. SPEC 5845
12431.711600.................. SPEC 5845
12431.711800.................. SPEC 5845
12431.715100.................. SPEC 5845
12431.715200.................. SPEC 5845
12431.715300.................. SPEC 5845
12431.715400.................. SPEC 5845
12431.716250.................. SPEC 5845
12431.716300.................. SPEC 5845
12431.716350.................. SPEC 5845
12431.716400.................. SPEC 5845
12431.716500.................. SPEC 5845
12431.716600.................. SPEC 5845
12431.716750.................. SPEC 5845
12431.717000.................. SPEC 5845
12441.710100.................. SPEC 5855
12441.710200.................. SPEC 5855
12441.710400.................. SPEC 5855
12441.710600.................. SPEC 5855
12441.710800.................. SPEC 5855
12441.711100.................. SPEC 5855
12441.711200.................. SPEC 5855
12441.711400.................. SPEC 5855
12441.711600.................. SPEC 5855
12441.711800.................. SPEC 5855
12441.715100.................. SPEC 5855
12441.715200.................. SPEC 5855
12441.715300.................. SPEC 5855
12441.715400.................. SPEC 5855
12441.716250.................. SPEC 5855
12441.716300.................. SPEC 5855
12441.716350.................. SPEC 5855
12441.716400.................. SPEC 5855
12441.716500.................. SPEC 5855
12441.716600.................. SPEC 5855
12441.716750.................. SPEC 5855
12441.717000.................. SPEC 5855
14101.210200.................. SPEC 5100
14101.210400.................. SPEC 5100
14101.210600.................. SPEC 5100
14101.210800.................. SPEC 5100
14101.211000.................. SPEC 5100

14101.211200.................. SPEC 5100
14101.211400.................. SPEC 5100
14101.215100.................. SPEC 5100
14101.215200.................. SPEC 5100
14101.215400.................. SPEC 5100
14101.216000.................. SPEC 5100
14101.216200.................. SPEC 5100
14101.216500.................. SPEC 5100
14101.217000.................. SPEC 5100
14101.217500.................. SPEC 5100
14311.010100.................. SPEC 5350
14311.010200.................. SPEC 5350
14311.010400.................. SPEC 5350
14311.010600.................. SPEC 5350
14311.010800.................. SPEC 5350
14311.011000.................. SPEC 5350
14311.011200.................. SPEC 5350
14311.011400.................. SPEC 5350
14311.015100.................. SPEC 5350
14311.015200.................. SPEC 5350
14311.015300.................. SPEC 5350
14311.015400.................. SPEC 5350
14311.016000.................. SPEC 5350
14311.016200.................. SPEC 5350
14311.016500.................. SPEC 5350
14311.017000.................. SPEC 5350
14315.010100.................. SPEC 5400
14315.010200.................. SPEC 5400
14315.010400.................. SPEC 5400
14315.010600.................. SPEC 5400
14315.010800.................. SPEC 5400
14315.011000.................. SPEC 5400
14315.011200.................. SPEC 5400
14315.011400.................. SPEC 5400
14315.015100.................. SPEC 5400
14315.015200.................. SPEC 5400
14315.015300.................. SPEC 5400
14315.015400.................. SPEC 5400
14315.016000.................. SPEC 5400
14315.016200.................. SPEC 5400
14315.016500.................. SPEC 5400
14315.017000.................. SPEC 5400
14407.247000.................. SPEC 4350
14407.546500.................. SPEC 4350
14407.547000.................. SPEC 4350
14428.030100.................. SPEC 4950
14428.030200.................. SPEC 4950
14428.030400.................. SPEC 4950
14428.030600.................. SPEC 4950
14428.030800.................. SPEC 4950
14428.035100.................. SPEC 4950
14428.035200.................. SPEC 4950
14428.035300.................. SPEC 4950
14428.035400.................. SPEC 4950
14428.036000.................. SPEC 4950
14428.036200.................. SPEC 4950
14428.036500.................. SPEC 4950
14428.037000.................. SPEC 4950
14428.040100.................. SPEC 4950
14428.040200.................. SPEC 4950
14428.040400.................. SPEC 4950
14428.040600.................. SPEC 4950
14428.040800.................. SPEC 4950
14428.045100.................. SPEC 4950
14428.045200.................. SPEC 4950
14428.045300.................. SPEC 4950
14428.045400.................. SPEC 4950
14428.046000.................. SPEC 4950
14428.046200.................. SPEC 4950
14428.046500.................. SPEC 4950
14428.047000.................. SPEC 4950
14511.410400.................. SPEC 5050
14511.410600.................. SPEC 5050

14511.410800.................. SPEC 5050
14511.411000.................. SPEC 5050
14511.411200.................. SPEC 5050
14511.411400.................. SPEC 5050
14511.710200.................. SPEC 5050
14511.715100.................. SPEC 5050
14511.715200.................. SPEC 5050
14511.715400.................. SPEC 5050
14511.716000.................. SPEC 5050
14511.716200.................. SPEC 5050
14511.716500.................. SPEC 5050
14511.717000.................. SPEC 5050
14511.717500.................. SPEC 5050
14711.410400.................. SPEC 5075
14711.410600.................. SPEC 5075
14711.410800.................. SPEC 5075
14711.411000.................. SPEC 5075
14711.411200.................. SPEC 5075
14711.411400.................. SPEC 5075
14711.710200.................. SPEC 5075
14711.715100.................. SPEC 5075
14711.715200.................. SPEC 5075
14711.715400.................. SPEC 5075
14711.716000.................. SPEC 5075
14711.716200.................. SPEC 5075
14711.716500.................. SPEC 5075
14711.717000.................. SPEC 5075
14711.717500.................. SPEC 5075
14901.410100.................. SPEC 6050
14901.410200.................. SPEC 6050
14901.410400.................. SPEC 6050
14901.410600.................. SPEC 6050
14901.410800.................. SPEC 6050
14901.415100.................. SPEC 6050
14901.415200.................. SPEC 6050
14901.415300.................. SPEC 6050
14901.415400.................. SPEC 6050
14901.416000.................. SPEC 6050
14901.416200.................. SPEC 6050
14901.416500.................. SPEC 6050
14901.417000.................. SPEC 6050
14901.417500.................. SPEC 6050
15493.400200.................. SPEC 6250
15493.400205.................. SPEC 6255
15493.400400.................. SPEC 6250
15493.400405.................. SPEC 6255
15493.400600.................. SPEC 6250
15493.400605.................. SPEC 6255
15493.405100.................. SPEC 6250
15493.405105.................. SPEC 6255
15493.405200.................. SPEC 6250
15493.405205.................. SPEC 6255
15493.405400.................. SPEC 6250
15493.405405.................. SPEC 6255
15493.406000.................. SPEC 6250
15493.406005.................. SPEC 6255
15493.406200.................. SPEC 6250
15493.406205.................. SPEC 6255
15493.406500.................. SPEC 6250
15493.406505.................. SPEC 6255
15493.407000.................. SPEC 6250
15493.407005.................. SPEC 6255
15493.407500.................. SPEC 6250
15493.407505.................. SPEC 6255
15493.440200.................. SPEC 6450
15493.440205.................. SPEC 6455
15493.445100.................. SPEC 6450
15493.445105.................. SPEC 6455
15493.445200.................. SPEC 6450
15493.445205.................. SPEC 6455
15493.445400.................. SPEC 6450
15493.445405.................. SPEC 6455
15493.446000.................. SPEC 6450

Phone: 888-593-3355
www.generalcable.com

Index	Industrial

Catalog Number Index
CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

15493.446005.................. SPEC 6455
15493.446200.................. SPEC 6450
15493.446205.................. SPEC 6455
15493.446500.................. SPEC 6450
15493.446505.................. SPEC 6455
15493.447000.................. SPEC 6450
15493.447005.................. SPEC 6455
15493.447500.................. SPEC 6450
15493.447505.................. SPEC 6455
15493.485100.................. SPEC 6600
15493.485105.................. SPEC 6605
15493.485200.................. SPEC 6600
15493.485205.................. SPEC 6605
15493.485400.................. SPEC 6600
15493.485405.................. SPEC 6605
15493.486000.................. SPEC 6600
15493.486005.................. SPEC 6605
15493.486200.................. SPEC 6600
15493.486205.................. SPEC 6605
15493.486500.................. SPEC 6600
15493.486505.................. SPEC 6605
15493.487000.................. SPEC 6600
15493.487005.................. SPEC 6605
15593.400200.................. SPEC 6275
15593.400400.................. SPEC 6275
15593.400600.................. SPEC 6275
15593.405100.................. SPEC 6275
15593.405200.................. SPEC 6275
15593.405400.................. SPEC 6275
15593.406000.................. SPEC 6275
15593.406200.................. SPEC 6275
15593.406500.................. SPEC 6275
15593.407000.................. SPEC 6275
15593.407500.................. SPEC 6275
15593.440200.................. SPEC 6475
15593.445100.................. SPEC 6475
15593.445200.................. SPEC 6475
15593.445400.................. SPEC 6475
15593.446000.................. SPEC 6475
15593.446200.................. SPEC 6475
15593.446500.................. SPEC 6475
15593.447000.................. SPEC 6475
15593.447500.................. SPEC 6475
15693.400200.................. SPEC 6280
15693.400400.................. SPEC 6280
15693.400600.................. SPEC 6280
15693.405100.................. SPEC 6280
15693.405200.................. SPEC 6280
15693.405400.................. SPEC 6280
15693.406000.................. SPEC 6280
15693.406200.................. SPEC 6280
15693.406500.................. SPEC 6280
15693.407000.................. SPEC 6280
15693.407500.................. SPEC 6280
15793.440200.................. SPEC 6480
15793.445100.................. SPEC 6480
15793.445200.................. SPEC 6480
15793.445400.................. SPEC 6480
15793.446000.................. SPEC 6480
15793.446200.................. SPEC 6480
15793.446500.................. SPEC 6480
15793.447000.................. SPEC 6480
15793.447500.................. SPEC 6480
16602.210200.................. SPEC 5250
16602.210400.................. SPEC 5250
16602.210600.................. SPEC 5250
16602.210800.................. SPEC 5250
16602.215100.................. SPEC 5250
16602.215200.................. SPEC 5250
16602.215400.................. SPEC 5250
16602.216000.................. SPEC 5250
16602.216200.................. SPEC 5250
16602.216500.................. SPEC 5250

16602.217000.................. SPEC 5250
16602.217500.................. SPEC 5250
17001.120100.................. SPEC 6150
17001.120105.................. SPEC 6155
17001.120108.................. SPEC 6160
17001.120200.................. SPEC 6150
17001.120205.................. SPEC 6155
17001.120208.................. SPEC 6160
17001.120400.................. SPEC 6150
17001.120405.................. SPEC 6155
17001.120408.................. SPEC 6160
17001.120600.................. SPEC 6150
17001.120605.................. SPEC 6155
17001.120608.................. SPEC 6160
17001.125100.................. SPEC 6150
17001.125105.................. SPEC 6155
17001.125108.................. SPEC 6160
17001.125200.................. SPEC 6150
17001.125205.................. SPEC 6155
17001.125208.................. SPEC 6160
17001.125300.................. SPEC 6150
17001.125305.................. SPEC 6155
17001.125308.................. SPEC 6160
17001.135400.................. SPEC 6150
17001.135405.................. SPEC 6155
17001.135408.................. SPEC 6160
17001.136000.................. SPEC 6150
17001.136005.................. SPEC 6155
17001.136008.................. SPEC 6160
17001.136200.................. SPEC 6150
17001.136205.................. SPEC 6155
17001.136208.................. SPEC 6160
17001.136500.................. SPEC 6150
17001.136505.................. SPEC 6155
17001.136508.................. SPEC 6160
17001.137000.................. SPEC 6150
17001.137005.................. SPEC 6155
17001.137008.................. SPEC 6160
17001.137508.................. SPEC 6160
17001.637500.................. SPEC 6150
17001.637505.................. SPEC 6155
17031.130100.................. SPEC 6350
17031.130105.................. SPEC 6355
17031.130108.................. SPEC 6360
17031.130200.................. SPEC 6350
17031.130205.................. SPEC 6355
17031.130208.................. SPEC 6360
17031.135100.................. SPEC 6350
17031.135105.................. SPEC 6355
17031.135108.................. SPEC 6360
17031.135200.................. SPEC 6350
17031.135205.................. SPEC 6355
17031.135208.................. SPEC 6360
17031.135300.................. SPEC 6350
17031.135305.................. SPEC 6355
17031.135308.................. SPEC 6360
17031.135400.................. SPEC 6350
17031.135405.................. SPEC 6355
17031.135408.................. SPEC 6360
17031.136000.................. SPEC 6350
17031.136005.................. SPEC 6355
17031.136008.................. SPEC 6360
17031.136200.................. SPEC 6350
17031.136205.................. SPEC 6355
17031.136208.................. SPEC 6360
17031.136500.................. SPEC 6350
17031.136505.................. SPEC 6355
17031.136508.................. SPEC 6360
17031.137000.................. SPEC 6350
17031.137005.................. SPEC 6355
17031.137008.................. SPEC 6360
17031.137500.................. SPEC 6350
17031.137505.................. SPEC 6355

17031.137508.................. SPEC 6360
17061.135100.................. SPEC 6550
17061.135105.................. SPEC 6555
17061.135108.................. SPEC 6560
17061.135200.................. SPEC 6550
17061.135205.................. SPEC 6555
17061.135208.................. SPEC 6560
17061.135300.................. SPEC 6550
17061.135305.................. SPEC 6555
17061.135308.................. SPEC 6560
17061.135400.................. SPEC 6550
17061.135405.................. SPEC 6555
17061.135408.................. SPEC 6560
17061.136000.................. SPEC 6550
17061.136005.................. SPEC 6555
17061.136008.................. SPEC 6560
17061.136200.................. SPEC 6550
17061.136205.................. SPEC 6555
17061.136208.................. SPEC 6560
17061.136500.................. SPEC 6550
17061.136505.................. SPEC 6555
17061.136508.................. SPEC 6560
17061.137000.................. SPEC 6550
17061.137005.................. SPEC 6555
17061.137008.................. SPEC 6560
17061.137500.................. SPEC 6550
17061.137505.................. SPEC 6555
17061.137508.................. SPEC 6560
17071.135100.................. SPEC 6650
17071.135105.................. SPEC 6655
17071.135108.................. SPEC 6660
17071.135200.................. SPEC 6650
17071.135205.................. SPEC 6655
17071.135208.................. SPEC 6660
17071.135300.................. SPEC 6650
17071.135305.................. SPEC 6655
17071.135308.................. SPEC 6660
17071.135400.................. SPEC 6650
17071.135405.................. SPEC 6655
17071.135408.................. SPEC 6660
17071.136000.................. SPEC 6650
17071.136005.................. SPEC 6655
17071.136008.................. SPEC 6660
17071.136200.................. SPEC 6650
17071.136205.................. SPEC 6655
17071.136208.................. SPEC 6660
17071.136500.................. SPEC 6650
17071.136505.................. SPEC 6655
17071.136508.................. SPEC 6660
17071.137000.................. SPEC 6650
17071.137005.................. SPEC 6655
17071.137008.................. SPEC 6660
17071.137500.................. SPEC 6650
17071.137505.................. SPEC 6655
17071.137508.................. SPEC 6660
17101.120100.................. SPEC 6175
17101.120200.................. SPEC 6175
17101.120400.................. SPEC 6175
17101.120600.................. SPEC 6175
17101.125100.................. SPEC 6175
17101.125200.................. SPEC 6175
17101.125300.................. SPEC 6175
17101.135400.................. SPEC 6175
17101.136000.................. SPEC 6175
17101.136200.................. SPEC 6175
17101.136500.................. SPEC 6175
17101.137000.................. SPEC 6175
17101.137500.................. SPEC 6175
17131.130100.................. SPEC 6375
17131.130200.................. SPEC 6375
17131.135100.................. SPEC 6375
17131.135200.................. SPEC 6375
17131.135300.................. SPEC 6375

17131.135400.................. SPEC 6375
17131.136000.................. SPEC 6375
17131.136200.................. SPEC 6375
17131.136500.................. SPEC 6375
17131.137000.................. SPEC 6375
17131.637500.................. SPEC 6375
17161.135100.................. SPEC 6575
17161.135200.................. SPEC 6575
17161.135300.................. SPEC 6575
17161.135400.................. SPEC 6575
17161.136000.................. SPEC 6575
17161.136200.................. SPEC 6575
17161.136500.................. SPEC 6575
17161.137000.................. SPEC 6575
17161.137500.................. SPEC 6575
17201.120100.................. SPEC 6180
17201.120200.................. SPEC 6180
17201.120400.................. SPEC 6180
17201.120600.................. SPEC 6180
17201.125100.................. SPEC 6180
17201.125200.................. SPEC 6180
17201.125300.................. SPEC 6180
17201.135400.................. SPEC 6180
17201.136000.................. SPEC 6180
17201.136200.................. SPEC 6180
17201.136500.................. SPEC 6180
17201.137000.................. SPEC 6180
17201.637500.................. SPEC 6180
17231.130100.................. SPEC 6380
17231.130200.................. SPEC 6380
17231.135100.................. SPEC 6380
17231.135200.................. SPEC 6380
17231.135300.................. SPEC 6380
17231.135400.................. SPEC 6380
17231.136000.................. SPEC 6380
17231.136200.................. SPEC 6380
17231.136500.................. SPEC 6380
17231.137000.................. SPEC 6380
17231.137500.................. SPEC 6380
17241.010200.................. SPEC 6200
17241.010400.................. SPEC 6200
17241.010600.................. SPEC 6200
17241.015100.................. SPEC 6200
17241.015200.................. SPEC 6200
17241.015400.................. SPEC 6200
17241.016000.................. SPEC 6200
17241.016200.................. SPEC 6200
17241.016500.................. SPEC 6200
17241.017000.................. SPEC 6200
17241.017500.................. SPEC 6200
17245.010100.................. SPEC 6400
17245.010200.................. SPEC 6400
17245.015100.................. SPEC 6400
17245.015200.................. SPEC 6400
17245.015400.................. SPEC 6400
17245.016000.................. SPEC 6400
17245.016200.................. SPEC 6400
17245.016500.................. SPEC 6400
17245.017000.................. SPEC 6400
17245.017500.................. SPEC 6400
17261.135100.................. SPEC 6580
17261.135200.................. SPEC 6580
17261.135300.................. SPEC 6580
17261.135400.................. SPEC 6580
17261.136000.................. SPEC 6580
17261.136200.................. SPEC 6580
17261.136500.................. SPEC 6580
17261.137000.................. SPEC 6580
17261.137500.................. SPEC 6580
17451.316781.................. SPEC 8450
17471.580200.................. SPEC 7200
17471.580400.................. SPEC 7200
17471.580600.................. SPEC 7200

Phone: 888-593-3355
www.generalcable.com

Industrial	Index

Catalog Number Index
CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

17471.585100.................. SPEC 7200
17471.585200.................. SPEC 7200
17471.585400.................. SPEC 7200
17471.586000.................. SPEC 7200
17471.586200.................. SPEC 7200
17471.586500.................. SPEC 7200
17471.587000.................. SPEC 7200
17471.587500.................. SPEC 7200
17473.530200.................. SPEC 7250
17473.530400.................. SPEC 7250
17473.530600.................. SPEC 7250
17473.535100.................. SPEC 7250
17473.535200.................. SPEC 7250
17473.535400.................. SPEC 7250
17473.536000.................. SPEC 7250
17473.536200.................. SPEC 7250
17473.536500.................. SPEC 7250
17473.537000.................. SPEC 7250
17473.537500.................. SPEC 7250
17476.515100.................. SPEC 7310
17476.515200.................. SPEC 7310
17476.515400.................. SPEC 7310
17476.516000.................. SPEC 7310
17476.516200.................. SPEC 7310
17476.516500.................. SPEC 7310
17476.517000.................. SPEC 7310
17476.517500.................. SPEC 7310
17476.530200.................. SPEC 7300
17476.535100.................. SPEC 7300
17476.535200.................. SPEC 7300
17476.535400.................. SPEC 7300
17476.536000.................. SPEC 7300
17476.536200.................. SPEC 7300
17476.536500.................. SPEC 7300
17476.537000.................. SPEC 7300
17476.537500.................. SPEC 7300
17477.517500.................. SPEC 7350
17477.535100.................. SPEC 7350
17477.535200.................. SPEC 7350
17477.535400.................. SPEC 7350
17477.536000.................. SPEC 7350
17477.536200.................. SPEC 7350
17477.536500.................. SPEC 7350
17477.537000.................. SPEC 7350
17480.535100.................. SPEC 7400
17480.535200.................. SPEC 7400
17480.535400.................. SPEC 7400
17480.536000.................. SPEC 7400
17480.536200.................. SPEC 7400
17480.536500.................. SPEC 7400
17480.537000.................. SPEC 7400
17496.010100.................. SPEC 8450
17496.010300.................. SPEC 8250
17496.015200.................. SPEC 8450
17496.017500.................. SPEC 8250
17496.020100.................. SPEC 8250
17496.020200.................. SPEC 8250
17496.020400.................. SPEC 8250
17496.020600.................. SPEC 8250
17496.025100.................. SPEC 8250
17496.025200.................. SPEC 8250
17496.025300.................. SPEC 8450
17496.025400.................. SPEC 8250
17496.026000.................. SPEC 8450
17496.026200.................. SPEC 8250
17496.030200.................. SPEC 8425
17496.035300.................. SPEC 8250
17496.035400.................. SPEC 8450
17496.037000.................. SPEC 8450
17496.046200.................. SPEC 8450
17496.046500.................. SPEC 8250
17496.056000.................. SPEC 8250
17496.056500.................. SPEC 8450

17496.077000.................. SPEC 8250
17496.100100.................. SPEC 8225
17496.100200.................. SPEC 8225
17496.100300.................. SPEC 8225
17496.100400.................. SPEC 8225
17496.100600.................. SPEC 8225
17496.105100.................. SPEC 8225
17496.105200.................. SPEC 8225
17496.105300.................. SPEC 8225
17496.105400.................. SPEC 8225
17496.106000.................. SPEC 8225
17496.106200.................. SPEC 8225
17496.106500.................. SPEC 8225
17496.107000.................. SPEC 8225
17496.107500.................. SPEC 8225
17496.216500.................. SPEC 8400
17496.230200.................. SPEC 8450
17496.536500.................. SPEC 8425
17496.700100.................. SPEC 8275
17496.700200.................. SPEC 8275
17496.700400.................. SPEC 8275
17496.700600.................. SPEC 8275
17496.705100.................. SPEC 8275
17496.705200.................. SPEC 8275
17496.705300.................. SPEC 8275
17496.705400.................. SPEC 8275
17496.706000.................. SPEC 8275
17496.706200.................. SPEC 8275
17496.706500.................. SPEC 8275
17496.707000.................. SPEC 8275
17496.707500.................. SPEC 8275
17496.710100.................. SPEC 8300
17496.710200.................. SPEC 8300
17496.710400.................. SPEC 8300
17496.710600.................. SPEC 8300
17496.715100.................. SPEC 8300
17496.715200.................. SPEC 8300
17496.715300.................. SPEC 8300
17496.715400.................. SPEC 8300
17496.716000.................. SPEC 8300
17496.716200.................. SPEC 8300
17496.716500.................. SPEC 8300
17496.717000.................. SPEC 8300
17496.717500.................. SPEC 8300
17496.740100.................. SPEC 8325
17496.740200.................. SPEC 8325
17496.740400.................. SPEC 8325
17496.740600.................. SPEC 8325
17496.745100.................. SPEC 8325
17496.745200.................. SPEC 8325
17496.745300.................. SPEC 8325
17496.745400.................. SPEC 8325
17496.746000.................. SPEC 8325
17496.746200.................. SPEC 8325
17496.746500.................. SPEC 8325
17496.747000.................. SPEC 8325
17496.747500.................. SPEC 8325
17496.750100.................. SPEC 8350
17496.750200.................. SPEC 8350
17496.750400.................. SPEC 8350
17496.750600.................. SPEC 8350
17496.755100.................. SPEC 8350
17496.755200.................. SPEC 8350
17496.755300.................. SPEC 8350
17496.755400.................. SPEC 8350
17496.756000.................. SPEC 8350
17496.756200.................. SPEC 8350
17496.756500.................. SPEC 8350
17496.757000.................. SPEC 8350
17496.757500.................. SPEC 8350
17496.810100.................. SPEC 8375
17496.810200.................. SPEC 8375
17496.815100.................. SPEC 8375

17496.815200.................. SPEC 8375
17496.815300.................. SPEC 8375
17496.815400.................. SPEC 8375
17496.816000.................. SPEC 8375
17496.816200.................. SPEC 8375
17496.816500.................. SPEC 8375
17496.817000.................. SPEC 8375
17496.817500.................. SPEC 8375
17496.820100.................. SPEC 8400
17496.825100.................. SPEC 8400
17496.825200.................. SPEC 8400
17496.825300.................. SPEC 8400
17496.825400.................. SPEC 8400
17496.826000.................. SPEC 8400
17496.826200.................. SPEC 8400
17496.826500.................. SPEC 8400
17496.827000.................. SPEC 8400
17496.827500.................. SPEC 8400
17496.830100.................. SPEC 8425
17496.835100.................. SPEC 8425
17496.835200.................. SPEC 8425
17496.835300.................. SPEC 8425
17496.835400.................. SPEC 8425
17496.836000.................. SPEC 8425
17496.836200.................. SPEC 8425
17496.837000.................. SPEC 8425
17496.837500.................. SPEC 8425
17496.850100.................. SPEC 8475
17496.855100.................. SPEC 8475
17496.855200.................. SPEC 8475
17496.855300.................. SPEC 8475
17496.855400.................. SPEC 8475
17496.856000.................. SPEC 8475
17496.856200.................. SPEC 8475
17496.856500.................. SPEC 8475
17496.860100.................. SPEC 8500
17496.865100.................. SPEC 8500
17496.865200.................. SPEC 8500
17496.865300.................. SPEC 8500
17496.865400.................. SPEC 8500
17496.866000.................. SPEC 8500
17496.866200.................. SPEC 8500
17496.890100.................. SPEC 8525
17496.895100.................. SPEC 8525
17496.895200.................. SPEC 8525
17496.895300.................. SPEC 8525
17496.895400.................. SPEC 8525
17496.896000.................. SPEC 8525
17496.896200.................. SPEC 8525
17497.055100.................. SPEC 8575
17497.055200.................. SPEC 8575
17497.055300.................. SPEC 8575
17497.055400.................. SPEC 8575
17497.056000.................. SPEC 8575
17497.056200.................. SPEC 8575
17497.056500.................. SPEC 8575
17497.440100.................. SPEC 8625
17497.440200.................. SPEC 8625
17497.445100.................. SPEC 8625
17497.445200.................. SPEC 8625
17497.445300.................. SPEC 8625
17497.445400.................. SPEC 8625
17497.446000.................. SPEC 8625
17497.446200.................. SPEC 8625
17497.446500.................. SPEC 8625
17497.447000.................. SPEC 8625
17497.540100.................. SPEC 8600
17497.540200.................. SPEC 8600
17497.545100.................. SPEC 8600
17497.545200.................. SPEC 8600
17497.545300.................. SPEC 8600
17497.545400.................. SPEC 8600
17497.546000.................. SPEC 8600

17497.546200.................. SPEC 8600
17497.546500.................. SPEC 8600
17497.547000.................. SPEC 8600
17602.210010.................. SPEC 5275
17602.210012.................. SPEC 5275
17602.210014.................. SPEC 5275
17602.210200.................. SPEC 5275
17602.210400.................. SPEC 5275
17602.210600.................. SPEC 5275
17602.210800.................. SPEC 5275
17602.215100.................. SPEC 5275
17602.215200.................. SPEC 5275
17602.215400.................. SPEC 5275
17602.216000.................. SPEC 5275
17602.216200.................. SPEC 5275
17602.216500.................. SPEC 5275
17602.217000.................. SPEC 5275
17602.217500.................. SPEC 5275
17946.895100.................. SPEC 8525
17946.895200.................. SPEC 8525
19101.650200.................. SPEC 6100
19101.655100.................. SPEC 6100
19101.665200.................. SPEC 6100
19101.665300.................. SPEC 6100
19101.665400.................. SPEC 6100
19101.667500.................. SPEC 6100
19101.676000.................. SPEC 6100
19101.676200.................. SPEC 6100
19101.686500.................. SPEC 6100
19101.687000.................. SPEC 6100
19161.307500.................. SPEC 6300
19161.660200.................. SPEC 6300
19161.665300.................. SPEC 6300
19161.675100.................. SPEC 6300
19161.675200.................. SPEC 6300
19161.675400.................. SPEC 6300
19161.686000.................. SPEC 6300
19161.686200.................. SPEC 6300
19161.686500.................. SPEC 6300
19161.697000.................. SPEC 6300
19261.685100.................. SPEC 6500
19261.685200.................. SPEC 6500
19261.685300.................. SPEC 6500
19261.685400.................. SPEC 6500
19261.686000.................. SPEC 6500
19261.686200.................. SPEC 6500
19261.686500.................. SPEC 6500
19261.687000.................. SPEC 6500
19261.687500.................. SPEC 6500
23010............................... SPEC 5290
23012............................... SPEC 5290
23014............................... SPEC 5290
24010............................... SPEC 5290
24012............................... SPEC 5290
24014............................... SPEC 5290
25001............................... SPEC 5290
25002............................... SPEC 5290
25003............................... SPEC 5290
25004............................... SPEC 5290
25006............................... SPEC 5290
25008............................... SPEC 5290
26110............................... SPEC 5290
26210............................... SPEC 5290
26310............................... SPEC 5290
26410............................... SPEC 5290
27250............................... SPEC 5290
27300............................... SPEC 5290
27350............................... SPEC 5290
27400............................... SPEC 5290
27500............................... SPEC 5290
27600............................... SPEC 5290
27750............................... SPEC 5290
81901............................... SPEC 5300

Phone: 888-593-3355
www.generalcable.com

Index	Industrial

Catalog Number Index
CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

81902............................... SPEC 5300
81904............................... SPEC 5300
81906............................... SPEC 5300
81908............................... SPEC 5300
81910............................... SPEC 5300
81911............................... SPEC 5300
81912............................... SPEC 5300
81914............................... SPEC 5300
81920............................... SPEC 5300
81926............................... SPEC 5300
81929............................... SPEC 5300
81930............................... SPEC 5300
81931............................... SPEC 5300
81937............................... SPEC 5300
81940............................... SPEC 5300
81944............................... SPEC 5300
81953............................... SPEC 5300
81964............................... SPEC 5300
81977............................... SPEC 5300
81999............................... SPEC 5300
149512M.......................... SPEC 5700
219580............................. SPEC 4750
219610............................. SPEC 4750
219630............................. SPEC 4750
221560............................. SPEC 4750
222490............................. SPEC 4750
222510............................. SPEC 4750
222570............................. SPEC 4550
222710............................. SPEC 4550
223640............................. SPEC 4050
223650............................. SPEC 4050
223670............................. SPEC 4050
223750............................. SPEC 4050
223760............................. SPEC 4050
223770............................. SPEC 4050
223780............................. SPEC 4050
223790............................. SPEC 4050
223910............................. SPEC 4050
223920............................. SPEC 4050
223930............................. SPEC 4050
224070............................. SPEC 4050
224080............................. SPEC 4050
224090............................. SPEC 4050
224100............................. SPEC 4050
224110............................. SPEC 4050
224120............................. SPEC 4050
224130............................. SPEC 4050
226410............................. SPEC 4750
226420............................. SPEC 4650
226430............................. SPEC 4750
226500............................. SPEC 4650
229600............................. SPEC 4700
230750............................. SPEC 2450
230760............................. SPEC 2450
230780............................. SPEC 2450
230790............................. SPEC 2450
230800............................. SPEC 2450
230810............................. SPEC 2450
230820............................. SPEC 2450
230830............................. SPEC 2450
230840............................. SPEC 2450
231980............................. SPEC 4750
232560............................. SPEC 2050
232850............................. SPEC 4050
233270............................. SPEC 4600
233310............................. SPEC 4075
233320............................. SPEC 4075
233330............................. SPEC 4075
234250............................. SPEC 4750
234260............................. SPEC 4750
234580............................. SPEC 4650
234590............................. SPEC 4650
234600............................. SPEC 4650

234620............................. SPEC 4650
234640............................. SPEC 4650
234680............................. SPEC 4650
235020............................. SPEC 2450
235040............................. SPEC 4650
235050............................. SPEC 4650
235060............................. SPEC 4650
235070............................. SPEC 4650
235080............................. SPEC 4650
235090............................. SPEC 4650
235110............................. SPEC 4650
235130............................. SPEC 4650
235150............................. SPEC 4650
235160............................. SPEC 4650
235170............................. SPEC 4650
235680............................. SPEC 4075
235750............................. SPEC 2500
235900............................. SPEC 2500
235910............................. SPEC 2450
235970............................. SPEC 2500
235980............................. SPEC 2450
235990............................. SPEC 2500
236090............................. SPEC 4600
236100............................. SPEC 4600
236120............................. SPEC 4600
236130............................. SPEC 4600
236140............................. SPEC 4600
236150............................. SPEC 4600
236160............................. SPEC 4600
236170............................. SPEC 4600
236180............................. SPEC 4600
236190............................. SPEC 4600
236210............................. SPEC 4600
236230............................. SPEC 4600
236240............................. SPEC 4600
236260............................. SPEC 4600
236280............................. SPEC 4600
236290............................. SPEC 4600
236300............................. SPEC 4650
236310............................. SPEC 4650
236320............................. SPEC 4650
236330............................. SPEC 4650
236340............................. SPEC 4650
236350............................. SPEC 4650
236370............................. SPEC 4750
236380............................. SPEC 4750
236400............................. SPEC 4750
236410............................. SPEC 4750
236420............................. SPEC 4750
236430............................. SPEC 4750
236440............................. SPEC 4750
237130............................. SPEC 2500
237160............................. SPEC 2500
237180............................. SPEC 2500
237490............................. SPEC 2450
237500............................. SPEC 4075
238410............................. SPEC 2450
238800............................. SPEC 3300
239200............................. SPEC 2450
239210............................. SPEC 2450
239620............................. SPEC 4075
239630............................. SPEC 4075
239640............................. SPEC 4075
239650............................. SPEC 4075
239660............................. SPEC 4075
239670............................. SPEC 4075
239680............................. SPEC 4075
239700............................. SPEC 4075
240990............................. SPEC 2050
241000............................. SPEC 2050
241010............................. SPEC 2050
241020............................. SPEC 2500
241030............................. SPEC 2500

241420............................. SPEC 4050
241430............................. SPEC 4050
241440............................. SPEC 4050
241510............................. SPEC 2050
242860............................. SPEC 2500
242870............................. SPEC 2500
243530............................. SPEC 4075
243540............................. SPEC 4075
243560............................. SPEC 4700
243570............................. SPEC 4700
243580............................. SPEC 4700
243600............................. SPEC 4650
243610............................. SPEC 4650
243620............................. SPEC 4650
243630............................. SPEC 4650
243640............................. SPEC 4600
243650............................. SPEC 4700
243660............................. SPEC 4700
243670............................. SPEC 4700
243690............................. SPEC 4700
243710............................. SPEC 4700
243720............................. SPEC 4700
243740............................. SPEC 4700
243760............................. SPEC 4750
243770............................. SPEC 4700
243810............................. SPEC 4700
243820............................. SPEC 4700
243840............................. SPEC 4700
243880............................. SPEC 2500
243890............................. SPEC 2500
244160............................. SPEC 4075
244590............................. SPEC 2450
244600............................. SPEC 2500
244610............................. SPEC 2450
244650............................. SPEC 4600
244660............................. SPEC 4600
244670............................. SPEC 4600
244680............................. SPEC 4600
244720............................. SPEC 4600
245310............................. SPEC 3300
245320............................. SPEC 3300
245330............................. SPEC 3300
245340............................. SPEC 3300
245350............................. SPEC 3300
245360............................. SPEC 3300
245370............................. SPEC 3300
245380............................. SPEC 3300
245390............................. SPEC 3300
245400............................. SPEC 3300
245410............................. SPEC 3300
245420............................. SPEC 3300
245440............................. SPEC 3300
245450............................. SPEC 3300
245580............................. SPEC 4600
245590............................. SPEC 4650
245920............................. SPEC 4600
247620............................. SPEC 4700
248240............................. SPEC 4200
248290............................. SPEC 4200
252230............................. SPEC 4075
252360............................. SPEC 4075
252370............................. SPEC 2050
252400............................. SPEC 4075
252410............................. SPEC 4075
255080............................. SPEC 4650
255090............................. SPEC 4650
256260............................. SPEC 4075
256300............................. SPEC 2500
256750............................. SPEC 4850
257730............................. SPEC 4850
257740............................. SPEC 4850
257750............................. SPEC 4850
257760............................. SPEC 4850

257770............................. SPEC 4850
257780............................. SPEC 4850
257790............................. SPEC 4850
257800............................. SPEC 4850
257810............................. SPEC 4850
259980............................. SPEC 4700
260000............................. SPEC 4700
260150............................. SPEC 4650
260730............................. SPEC 4050
261000............................. SPEC 4250
261010............................. SPEC 4250
261130............................. SPEC 4700
261140............................. SPEC 4700
261150............................. SPEC 4700
261160............................. SPEC 4700
261690............................. SPEC 4850
262130............................. SPEC 4200
262140............................. SPEC 4200
262150............................. SPEC 4200
262160............................. SPEC 4200
262190............................. SPEC 4200
262200............................. SPEC 4200
262680............................. SPEC 4075
264570............................. SPEC 4600
264990............................. SPEC 4200
265940............................. SPEC 4050
266580............................. SPEC 4700
267830............................. SPEC 4850
267840............................. SPEC 4850
267860............................. SPEC 4850
267950............................. SPEC 4850
269080............................. SPEC 4850
270720............................. SPEC 4850
270730............................. SPEC 4850
270970............................. SPEC 2450
271740............................. SPEC 4850
272260............................. SPEC 4050
272270............................. SPEC 4050
277460............................. SPEC 4650
277820............................. SPEC 2500
279560............................. SPEC 4300
279570............................. SPEC 4300
279580............................. SPEC 4300
279590............................. SPEC 4300
279600............................. SPEC 4300
279610............................. SPEC 4300
279620............................. SPEC 4300
279630............................. SPEC 4300
279640............................. SPEC 4300
279650............................. SPEC 4300
279660............................. SPEC 4350
279670............................. SPEC 4350
279680............................. SPEC 4300
279690............................. SPEC 2100
279700............................. SPEC 2150
279710............................. SPEC 2150
279720............................. SPEC 2150
279730............................. SPEC 2150
279740............................. SPEC 2150
279750............................. SPEC 2150
279760............................. SPEC 2150
279770............................. SPEC 2150
279840............................. SPEC 4300
279850............................. SPEC 4310
279870............................. SPEC 4300
279880............................. SPEC 4300
279890............................. SPEC 4300
279900............................. SPEC 4300
279910............................. SPEC 4310
279920............................. SPEC 4310
279930............................. SPEC 4310
280170............................. SPEC 4300
280180............................. SPEC 4300

Phone: 888-593-3355
www.generalcable.com

Industrial	Index

Catalog Number Index
CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

280190............................. SPEC 4300
280200............................. SPEC 4300
280210............................. SPEC 4300
280230............................. SPEC 4310
280240............................. SPEC 4310
280250............................. SPEC 4310
280260............................. SPEC 4310
280270............................. SPEC 4310
280280............................. SPEC 4310
280290............................. SPEC 4310
280300............................. SPEC 4300
280310............................. SPEC 4300
280320............................. SPEC 4300
280330............................. SPEC 4300
280340............................. SPEC 4300
280350............................. SPEC 4310
280360............................. SPEC 4310
280370............................. SPEC 4310
280380............................. SPEC 4310
280390............................. SPEC 4310
280400............................. SPEC 4310
280410............................. SPEC 4300
280420............................. SPEC 4310
280430............................. SPEC 4310
280470............................. SPEC 4325
280490............................. SPEC 4325
280500............................. SPEC 2150
280520............................. SPEC 2150
280530............................. SPEC 2150
280540............................. SPEC 2150
280590............................. SPEC 4310
280600............................. SPEC 4310
280950............................. SPEC 2200
280960............................. SPEC 2200
280970............................. SPEC 2200
280980............................. SPEC 4325
280990............................. SPEC 2150
282570............................. SPEC 4100
282580............................. SPEC 4100
282590............................. SPEC 4100
282600............................. SPEC 4100
282610............................. SPEC 4100
282620............................. SPEC 4100
282630............................. SPEC 4100
282640............................. SPEC 4100
282650............................. SPEC 4100
282660............................. SPEC 4100
282670............................. SPEC 4100
282680............................. SPEC 4100
282690............................. SPEC 4100
282710............................. SPEC 4100
283170............................. SPEC 2100
283180............................. SPEC 2100
283190............................. SPEC 2100
283200............................. SPEC 4350
283210............................. SPEC 4350
283220............................. SPEC 4350
283530............................. SPEC 4800
283540............................. SPEC 4800
284560............................. SPEC 4350
285150............................. SPEC 2050
285890............................. SPEC 4350
286130............................. SPEC 4850
287410............................. SPEC 2200
287650............................. SPEC 2100
288250............................. SPEC 2150
288260............................. SPEC 2150
292410............................. SPEC 4100
292686M.......................... SPEC 5700
293570............................. SPEC 8075
293600............................. SPEC 4350
294530............................. SPEC 4350
294540............................. SPEC 2200

294580............................. SPEC 2100
295320............................. SPEC 4500
295360............................. SPEC 4350
295390............................. SPEC 4350
295400............................. SPEC 4300
295890............................. SPEC 4350
296440............................. SPEC 4350
296450............................. SPEC 4350
297050............................. SPEC 4750
297060............................. SPEC 4750
297730............................. SPEC 4350
298020............................. SPEC 4350
298830............................. SPEC 1250
298880............................. SPEC 1300
298890............................. SPEC 1300
299950............................. SPEC 8050
299980............................. SPEC 8025
300380............................. SPEC 4350
300780............................. SPEC 4350
301870............................. SPEC 4300
304030............................. SPEC 8050
305300............................. SPEC 4325
305320............................. SPEC 4300
305340............................. SPEC 4300
305360............................. SPEC 4325
307450............................. SPEC 8075
307460............................. SPEC 8075
307470............................. SPEC 8050
307690............................. SPEC 4300
308180............................. SPEC 8075
308190............................. SPEC 8025
308550............................. SPEC 8125
309340............................. SPEC 4100
309520............................. SPEC 1050
309540............................. SPEC 1100
309550............................. SPEC 1100
309560............................. SPEC 1100
309570............................. SPEC 1100
309580............................. SPEC 1100
309660............................. SPEC 1050
309670............................. SPEC 1050
309680............................. SPEC 1050
309690............................. SPEC 1050
309700............................. SPEC 1050
311320............................. SPEC 8200
311330............................. SPEC 8200
311560............................. SPEC 8050
311570............................. SPEC 8075
311640............................. SPEC 1050
311900............................. SPEC 4325
311910............................. SPEC 4325
312500............................. SPEC 4050
312510............................. SPEC 4050
312520............................. SPEC 4050
312910............................. SPEC 8050
312990............................. SPEC 8050
313406M.......................... SPEC 5700
314960............................. SPEC 2100
315020............................. SPEC 8050
317890............................. SPEC 8075
318050............................. SPEC 4600
318730............................. SPEC 8050
318740............................. SPEC 8075
318750............................. SPEC 8075
319250............................. SPEC 2200
319260............................. SPEC 2200
319270............................. SPEC 2150
319480............................. SPEC 8075
319740............................. SPEC 2450
319810............................. SPEC 2350
319820............................. SPEC 2400
319840............................. SPEC 2400
319850............................. SPEC 2400

319870............................. SPEC 2350
321720............................. SPEC 4650
321940............................. SPEC 8175
324820............................. SPEC 3150
325110............................. SPEC 4350
325120............................. SPEC 4350
325250............................. SPEC 2100
325610............................. SPEC 4550
325700............................. SPEC 4350
325770............................. SPEC 1250
325780............................. SPEC 1250
325790............................. SPEC 1250
325800............................. SPEC 1300
325810............................. SPEC 1250
325820............................. SPEC 1300
325830............................. SPEC 1250
325840............................. SPEC 1250
325850............................. SPEC 1250
325860............................. SPEC 1300
325870............................. SPEC 1350
325880............................. SPEC 1250
325890............................. SPEC 1300
325900............................. SPEC 1250
325910............................. SPEC 1250
325920............................. SPEC 1250
325930............................. SPEC 1300
325940............................. SPEC 1250
325950............................. SPEC 1300
326640............................. SPEC 4325
326650............................. SPEC 4325
326660............................. SPEC 4325
326670............................. SPEC 4325
328540............................. SPEC 4550
329240............................. SPEC 4750
330090............................. SPEC 8025
330280............................. SPEC 8025
330520............................. SPEC 8150
330580............................. SPEC 4075
330800............................. SPEC 4310
330990............................. SPEC 4310
331120............................. SPEC 8150
331130............................. SPEC 8050
331150............................. SPEC 4100
331190............................. SPEC 8050
331250............................. SPEC 8175
331260............................. SPEC 8125
332010............................. SPEC 3300
333160............................. SPEC 8075
333410............................. SPEC 8200
333750............................. SPEC 8025
334630............................. SPEC 1250
336830............................. SPEC 2450
336840............................. SPEC 2450
336850............................. SPEC 2450
336860............................. SPEC 2450
336870............................. SPEC 2450
336880............................. SPEC 2450
336890............................. SPEC 2450
336900............................. SPEC 2500
336910............................. SPEC 2500
336920............................. SPEC 2500
336930............................. SPEC 2500
336940............................. SPEC 2500
336950............................. SPEC 2500
336960............................. SPEC 2500
337010............................. SPEC 2100
337020............................. SPEC 2100
337030............................. SPEC 2100
337040............................. SPEC 2100
337050............................. SPEC 2100
337060............................. SPEC 2100
337070............................. SPEC 2100
337080............................. SPEC 2100

337090............................. SPEC 2100
337100............................. SPEC 2100
337110............................. SPEC 2100
337120............................. SPEC 2100
337130............................. SPEC 2100
337140............................. SPEC 2100
337150............................. SPEC 2200
337160............................. SPEC 2200
337170............................. SPEC 2200
337180............................. SPEC 2200
337190............................. SPEC 2200
337200............................. SPEC 2200
337210............................. SPEC 2200
337220............................. SPEC 2200
337230............................. SPEC 2200
337240............................. SPEC 2150
337250............................. SPEC 2150
337260............................. SPEC 2150
337270............................. SPEC 2350
337280............................. SPEC 2350
337290............................. SPEC 2350
337300............................. SPEC 2350
337310............................. SPEC 2350
337320............................. SPEC 2350
337330............................. SPEC 2350
337340............................. SPEC 2350
337350............................. SPEC 2350
337360............................. SPEC 2350
337370............................. SPEC 2350
337390............................. SPEC 2350
337400............................. SPEC 2350
337410............................. SPEC 2350
337420............................. SPEC 2350
337430............................. SPEC 2350
337440............................. SPEC 2350
337450............................. SPEC 2350
337460............................. SPEC 2400
337470............................. SPEC 2400
337480............................. SPEC 2400
337490............................. SPEC 2400
337500............................. SPEC 2400
337510............................. SPEC 2400
337520............................. SPEC 2400
337530............................. SPEC 2400
337540............................. SPEC 2400
337550............................. SPEC 2400
337560............................. SPEC 2400
337570............................. SPEC 2400
337580............................. SPEC 2400
337590............................. SPEC 2400
337600............................. SPEC 2400
337620............................. SPEC 2050
337630............................. SPEC 2050
337640............................. SPEC 2050
337650............................. SPEC 2050
337660............................. SPEC 2050
337670............................. SPEC 2050
337680............................. SPEC 2050
337690............................. SPEC 2050
337700............................. SPEC 2050
337710............................. SPEC 2050
337720............................. SPEC 2050
337730............................. SPEC 2050
337740............................. SPEC 2050
337750............................. SPEC 2050
337760............................. SPEC 2050
337770............................. SPEC 1050
337780............................. SPEC 1050
337790............................. SPEC 1050
337800............................. SPEC 1050
337810............................. SPEC 1050
337820............................. SPEC 1050
337830............................. SPEC 1050

Phone: 888-593-3355
www.generalcable.com

Index	Industrial

Catalog Number Index
CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

337840............................. SPEC 1050
337850............................. SPEC 1050
337860............................. SPEC 1050
337870............................. SPEC 1050
337880............................. SPEC 1050
337890............................. SPEC 1050
337900............................. SPEC 1050
337910............................. SPEC 1050
337920............................. SPEC 1050
337930............................. SPEC 1050
337940............................. SPEC 1050
337950............................. SPEC 1050
337960............................. SPEC 1050
337970............................. SPEC 1050
337980............................. SPEC 1050
337990............................. SPEC 1050
338000............................. SPEC 1050
338010............................. SPEC 1050
338020............................. SPEC 1050
338030............................. SPEC 1100
338040............................. SPEC 1100
338050............................. SPEC 1100
338060............................. SPEC 1100
338070............................. SPEC 1100
338080............................. SPEC 1100
338090............................. SPEC 1100
338100............................. SPEC 1100
338110............................. SPEC 1100
338120............................. SPEC 1100
338130............................. SPEC 1100
338140............................. SPEC 1100
338150............................. SPEC 1100
338160............................. SPEC 1100
338170............................. SPEC 1100
338180............................. SPEC 1100
338190............................. SPEC 1100
338200............................. SPEC 1100
338210............................. SPEC 1100
338220............................. SPEC 1100
338230............................. SPEC 1100
338240............................. SPEC 1100
338310............................. SPEC 4250
338670............................. SPEC 4250
338680............................. SPEC 4250
338690............................. SPEC 4250
338700............................. SPEC 4250
338710............................. SPEC 4250
338720............................. SPEC 4250
338730............................. SPEC 4250
338740............................. SPEC 4250
338750............................. SPEC 4250
338770............................. SPEC 4250
338780............................. SPEC 4250
338790............................. SPEC 4250
338800............................. SPEC 4250
338820............................. SPEC 4250
338830............................. SPEC 4250
338860............................. SPEC 4100
338880............................. SPEC 4100
338890............................. SPEC 4100
338900............................. SPEC 4100
338910............................. SPEC 4100
339170............................. SPEC 3250
339180............................. SPEC 3250
339190............................. SPEC 3250
339200............................. SPEC 3250
339210............................. SPEC 3250
339220............................. SPEC 3250
339230............................. SPEC 3250
339240............................. SPEC 3250
339250............................. SPEC 3250
339260............................. SPEC 3250
339270............................. SPEC 3250

339280............................. SPEC 3250
339290............................. SPEC 3250
339300............................. SPEC 3250
339310............................. SPEC 3250
339320............................. SPEC 3250
339330............................. SPEC 3250
339340............................. SPEC 3250
339350............................. SPEC 3250
339360............................. SPEC 3250
339370............................. SPEC 3250
339380............................. SPEC 3250
339390............................. SPEC 3250
339400............................. SPEC 3250
339410............................. SPEC 3250
339420............................. SPEC 3250
339430............................. SPEC 3250
339440............................. SPEC 3250
339450............................. SPEC 3250
339460............................. SPEC 3250
339470............................. SPEC 4550
339480............................. SPEC 4550
339500............................. SPEC 4550
339520............................. SPEC 4550
339530............................. SPEC 4550
339540............................. SPEC 4550
339550............................. SPEC 4550
339560............................. SPEC 4550
339570............................. SPEC 4550
339590............................. SPEC 4550
339600............................. SPEC 4550
339620............................. SPEC 1250
339650............................. SPEC 1250
339660............................. SPEC 1250
339670............................. SPEC 1250
339680............................. SPEC 1250
339690............................. SPEC 1250
339700............................. SPEC 1250
339710............................. SPEC 1250
339720............................. SPEC 1250
339730............................. SPEC 1250
339740............................. SPEC 1250
339750............................. SPEC 1300
339760............................. SPEC 1300
339770............................. SPEC 1300
339780............................. SPEC 1300
339800............................. SPEC 1300
339810............................. SPEC 1300
339820............................. SPEC 1300
339830............................. SPEC 1300
339840............................. SPEC 1300
339850............................. SPEC 1300
339860............................. SPEC 1300
339870............................. SPEC 1350
339880............................. SPEC 1350
339890............................. SPEC 1350
339900............................. SPEC 1350
339910............................. SPEC 1350
339920............................. SPEC 1350
339930............................. SPEC 1350
339940............................. SPEC 1350
339960............................. SPEC 1350
339980............................. SPEC 1350
339990............................. SPEC 1350
340000............................. SPEC 1350
340010............................. SPEC 1350
340020............................. SPEC 1350
340030............................. SPEC 1350
340040............................. SPEC 1350
340050............................. SPEC 1350
340060............................. SPEC 1350
340070............................. SPEC 1350
340080............................. SPEC 1350
340090............................. SPEC 1350

341790............................. SPEC 1300
342930............................. SPEC 1150
342940............................. SPEC 1150
342950............................. SPEC 1150
342960............................. SPEC 1150
342970............................. SPEC 1150
342980............................. SPEC 1150
342990............................. SPEC 1150
343000............................. SPEC 1150
343010............................. SPEC 1150
343020............................. SPEC 1150
343030............................. SPEC 1150
343040............................. SPEC 1150
343050............................. SPEC 1150
343060............................. SPEC 1150
343070............................. SPEC 1150
343080............................. SPEC 1150
343090............................. SPEC 1150
343100............................. SPEC 1150
343110............................. SPEC 1150
343120............................. SPEC 1150
343140............................. SPEC 1200
343150............................. SPEC 1200
343160............................. SPEC 1200
343170............................. SPEC 1200
343180............................. SPEC 1200
343190............................. SPEC 1200
343200............................. SPEC 1200
343210............................. SPEC 1200
343220............................. SPEC 1200
343240............................. SPEC 1200
343250............................. SPEC 1200
343260............................. SPEC 1200
343270............................. SPEC 1200
343280............................. SPEC 1200
343290............................. SPEC 1200
343300............................. SPEC 1200
343310............................. SPEC 1200
343320............................. SPEC 1200
343330............................. SPEC 4150
343340............................. SPEC 4150
343350............................. SPEC 4150
343360............................. SPEC 4150
343370............................. SPEC 4150
343380............................. SPEC 4150
343390............................. SPEC 4150
343400............................. SPEC 4150
343410............................. SPEC 4150
343420............................. SPEC 4150
343430............................. SPEC 4150
343440............................. SPEC 4150
343450............................. SPEC 4150
343460............................. SPEC 4150
343470............................. SPEC 4150
343480............................. SPEC 4150
343490............................. SPEC 4150
343500............................. SPEC 4150
343510............................. SPEC 4150
343520............................. SPEC 4150
343530............................. SPEC 4150
343540............................. SPEC 4150
343550............................. SPEC 4150
343560............................. SPEC 4150
343570............................. SPEC 4150
343580............................. SPEC 4150
343590............................. SPEC 4200
343600............................. SPEC 4200
343630............................. SPEC 4200
343640............................. SPEC 4200
343650............................. SPEC 4200
343660............................. SPEC 4200
343670............................. SPEC 4200
343680............................. SPEC 4200

343690............................. SPEC 4200
343700............................. SPEC 4200
343710............................. SPEC 4200
343730............................. SPEC 4200
343750............................. SPEC 4200
343760............................. SPEC 4200
343770............................. SPEC 4200
343780............................. SPEC 4200
343790............................. SPEC 4200
343800............................. SPEC 4200
343810............................. SPEC 4200
343820............................. SPEC 4200
343830............................. SPEC 4200
343840............................. SPEC 4200
343860............................. SPEC 4200
346410............................. SPEC 7050
346420............................. SPEC 7050
346430............................. SPEC 7050
346440............................. SPEC 7050
346450............................. SPEC 7050
346460............................. SPEC 7050
346470............................. SPEC 7050
346480............................. SPEC 7050
346490............................. SPEC 7050
346500............................. SPEC 7050
346510............................. SPEC 7050
346520............................. SPEC 7050
346530............................. SPEC 7050
346540............................. SPEC 7050
346550............................. SPEC 7050
346560............................. SPEC 7050
346570............................. SPEC 7050
346580............................. SPEC 7050
346590............................. SPEC 7050
346600............................. SPEC 7050
346610............................. SPEC 7050
346620............................. SPEC 7050
346630............................. SPEC 7100
346640............................. SPEC 7100
346870............................. SPEC 8075
346880............................. SPEC 8050
346890............................. SPEC 8050
346900............................. SPEC 8075
346920............................. SPEC 4500
346930............................. SPEC 4500
346980............................. SPEC 4350
346990............................. SPEC 4350
347000............................. SPEC 4350
347050............................. SPEC 4050
347060............................. SPEC 4050
347070............................. SPEC 4050
347080............................. SPEC 4300
347100............................. SPEC 4300
347110............................. SPEC 4500
347120............................. SPEC 4500
347130............................. SPEC 4500
347140............................. SPEC 4600
347150............................. SPEC 4450
347160............................. SPEC 4450
347170............................. SPEC 4450
347180............................. SPEC 4450
347190............................. SPEC 4450
347200............................. SPEC 4450
347210............................. SPEC 4450
347220............................. SPEC 4450
347230............................. SPEC 4450
347240............................. SPEC 4450
347250............................. SPEC 4450
347260............................. SPEC 4450
347270............................. SPEC 4450
347280............................. SPEC 4450
347290............................. SPEC 4450
347300............................. SPEC 4450

Phone: 888-593-3355
www.generalcable.com

Industrial	Index

Catalog Number Index
CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

347310............................. SPEC 4450
347320............................. SPEC 4450
347330............................. SPEC 4450
347340............................. SPEC 4400
347350............................. SPEC 4400
347360............................. SPEC 4400
347370............................. SPEC 4400
347380............................. SPEC 4400
347390............................. SPEC 4400
347400............................. SPEC 4400
347410............................. SPEC 4400
347420............................. SPEC 4400
347430............................. SPEC 4400
347440............................. SPEC 4400
347450............................. SPEC 4400
347460............................. SPEC 4400
347470............................. SPEC 4400
347480............................. SPEC 4400
347490............................. SPEC 4400
347500............................. SPEC 4400
347510............................. SPEC 4400
347520............................. SPEC 4400
347530............................. SPEC 4400
347540............................. SPEC 4400
347550............................. SPEC 4400
347560............................. SPEC 4400
347570............................. SPEC 4400
347580............................. SPEC 4400
347590............................. SPEC 4400
347600............................. SPEC 4400
347610............................. SPEC 4400
347620............................. SPEC 4400
347630............................. SPEC 2250
347640............................. SPEC 2250
347650............................. SPEC 2250
347660............................. SPEC 2250
347670............................. SPEC 2250
347680............................. SPEC 2250
347690............................. SPEC 2250
347700............................. SPEC 2250
347710............................. SPEC 2250
347720............................. SPEC 2250
347730............................. SPEC 2250
347740............................. SPEC 2250
347750............................. SPEC 2250
347760............................. SPEC 2250
347770............................. SPEC 2250
347780............................. SPEC 2250
347790............................. SPEC 2250
347800............................. SPEC 2250
347810............................. SPEC 2250
347820............................. SPEC 2250
347830............................. SPEC 2300
347840............................. SPEC 2300
347850............................. SPEC 2300
347860............................. SPEC 2300
347870............................. SPEC 2300
347880............................. SPEC 2300
347890............................. SPEC 2300
347900............................. SPEC 2300
347910............................. SPEC 2300
347920............................. SPEC 2300
347930............................. SPEC 2300
347940............................. SPEC 2300
347950............................. SPEC 2300
347960............................. SPEC 2300
347970............................. SPEC 2300
347980............................. SPEC 2300
347990............................. SPEC 2300
348000............................. SPEC 2300
348010............................. SPEC 1350
348020............................. SPEC 1250
348030............................. SPEC 1250

348040............................. SPEC 1250
348060............................. SPEC 1300
348070............................. SPEC 1300
348090............................. SPEC 1250
348100............................. SPEC 1250
348110............................. SPEC 1300
348120............................. SPEC 1300
352150............................. SPEC 4550
354800............................. SPEC 4325
354810............................. SPEC 4325
354820............................. SPEC 4325
354830............................. SPEC 4325
355210............................. SPEC 4050
356740............................. SPEC 4350
360990............................. SPEC 4250
361350............................. SPEC 4050
363310............................. SPEC 4800
364830............................. SPEC 5250
364840............................. SPEC 5250
364850............................. SPEC 5250
365240............................. SPEC 4850
365290............................. SPEC 4800
365300............................. SPEC 4800
365320............................. SPEC 4800
365330............................. SPEC 4800
365340............................. SPEC 4800
365350............................. SPEC 4800
365360............................. SPEC 4800
365370............................. SPEC 4800
365380............................. SPEC 4800
365390............................. SPEC 4800
365400............................. SPEC 4800
365410............................. SPEC 4850
365430............................. SPEC 4850
365680............................. SPEC 3300
365720............................. SPEC 4500
365750............................. SPEC 4350
366070............................. SPEC 4100
366080............................. SPEC 4100
366090............................. SPEC 4100
366100............................. SPEC 4100
366140............................. SPEC 1150
366150............................. SPEC 1150
366160............................. SPEC 2350
366170............................. SPEC 2250
366180............................. SPEC 2250
366190............................. SPEC 4150
366200............................. SPEC 4150
366210............................. SPEC 4250
366220............................. SPEC 4250
366230............................. SPEC 4250
366240............................. SPEC 4250
366250............................. SPEC 4250
367120............................. SPEC 4325
367130............................. SPEC 4325
367140............................. SPEC 4325
367150............................. SPEC 4325
367160............................. SPEC 4325
367170............................. SPEC 4325
367180............................. SPEC 4325
367190............................. SPEC 4325
367200............................. SPEC 4325
367210............................. SPEC 4325
367220............................. SPEC 4325
367230............................. SPEC 4325
367240............................. SPEC 4325
367250............................. SPEC 4325
367260............................. SPEC 4325
367270............................. SPEC 4325
371250............................. SPEC 4550
371260............................. SPEC 4550
371270............................. SPEC 4550
371280............................. SPEC 4450

371290............................. SPEC 4450
371300............................. SPEC 4450
371310............................. SPEC 4450
375010............................. SPEC 4075
375470............................. SPEC 4075
381500............................. SPEC 5150
381510............................. SPEC 5150
381520............................. SPEC 5150
381530............................. SPEC 5150
381540............................. SPEC 5150
381550............................. SPEC 5150
381560............................. SPEC 5150
381570............................. SPEC 5150
382260............................. SPEC 2350
382880............................. SPEC 4310
383230............................. SPEC 4550
383790............................. SPEC 4100
383800............................. SPEC 4250
383810............................. SPEC 4250
383820............................. SPEC 4250
383830............................. SPEC 4350
383840............................. SPEC 4350
383860............................. SPEC 4550
383870............................. SPEC 4550
383880............................. SPEC 4550
383890............................. SPEC 4750
383930............................. SPEC 4310
383940............................. SPEC 4310
383950............................. SPEC 4310
383970............................. SPEC 4310
383980............................. SPEC 4075
383990............................. SPEC 4075
384000............................. SPEC 4075
384010............................. SPEC 4075
384020............................. SPEC 4075
384030............................. SPEC 4075
384040............................. SPEC 4075
384730............................. SPEC 4575
384740............................. SPEC 4575
384750............................. SPEC 4575
384760............................. SPEC 4575
384770............................. SPEC 4575
384780............................. SPEC 4575
384790............................. SPEC 4575
384800............................. SPEC 4575
384810............................. SPEC 4575
384820............................. SPEC 4575
384830............................. SPEC 4575
384840............................. SPEC 4575
384850............................. SPEC 4575
384860............................. SPEC 4575
385350........................... SPEC 4310
385360............................. SPEC 4310
385370............................. SPEC 4310
386700............................. SPEC 4750
389710............................. SPEC 4800
391070............................. SPEC 5175
391080............................. SPEC 5175
391090............................. SPEC 5175
393710............................. SPEC 2600
393720............................. SPEC 2600
393730............................. SPEC 2600
393740............................. SPEC 2600
393750............................. SPEC 2600
393760............................. SPEC 2600
393770............................. SPEC 2600
393780............................. SPEC 2600
393790............................. SPEC 2600
393800............................. SPEC 2600
393810............................. SPEC 2600
393820............................. SPEC 2600
393830............................. SPEC 2600
393840............................. SPEC 2600

393850............................. SPEC 2600
393860............................. SPEC 2600
393870............................. SPEC 2600
393880............................. SPEC 2600
393890............................. SPEC 2600
393900............................. SPEC 2600
393910............................. SPEC 2600
393920............................. SPEC 2600
393930............................. SPEC 2625
393940............................. SPEC 2625
393950............................. SPEC 2625
393960............................. SPEC 2625
393970............................. SPEC 2625
393980............................. SPEC 2625
393990............................. SPEC 2625
394000............................. SPEC 2625
394010............................. SPEC 2625
394020............................. SPEC 2625
394030............................. SPEC 2625
394040............................. SPEC 2625
394050............................. SPEC 2625
394060............................. SPEC 2625
394070............................. SPEC 2625
394080............................. SPEC 2625
394090............................. SPEC 2625
394100............................. SPEC 2625
394110............................. SPEC 2625
394120............................. SPEC 2650
394130............................. SPEC 2650
394140............................. SPEC 2650
394150............................. SPEC 2650
394160............................. SPEC 2650
394170............................. SPEC 2650
394180............................. SPEC 2650
394190............................. SPEC 2650
394200............................. SPEC 2650
394210............................. SPEC 2650
394220............................. SPEC 2650
394230............................. SPEC 2650
394240............................. SPEC 2650
394250............................. SPEC 2650
394260............................. SPEC 2650
394270............................. SPEC 2650
394280............................. SPEC 4900
394290............................. SPEC 4900
394300............................. SPEC 4900
394310............................. SPEC 4900
394320............................. SPEC 4900
394330............................. SPEC 4900
394340............................. SPEC 4900
394350............................. SPEC 4900
394360............................. SPEC 4900
394370............................. SPEC 4900
394380............................. SPEC 4900
394390............................. SPEC 4900
394400............................. SPEC 4900
394410............................. SPEC 4900
394420............................. SPEC 4900
394430............................. SPEC 4900
394440............................. SPEC 4900
394450............................. SPEC 4900
394460............................. SPEC 4900
394470............................. SPEC 4900
394480............................. SPEC 4900
394490............................. SPEC 4900
394500............................. SPEC 4900
394510............................. SPEC 4900
394520............................. SPEC 4900
394530............................. SPEC 4900
394540............................. SPEC 4900
394550............................. SPEC 4900
394560............................. SPEC 4900
394570............................. SPEC 4900

Phone: 888-593-3355
www.generalcable.com

Index	Industrial

Catalog Number Index
CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

CATALOG
NUMBER	PAGE

394580............................. SPEC 4900
394590............................. SPEC 4900
394600............................. SPEC 4900
394610............................. SPEC 4900
394630............................. SPEC 4925
394640............................. SPEC 4925
394650............................. SPEC 4925
394660............................. SPEC 4925
394670............................. SPEC 4925
394680............................. SPEC 4925
394690............................. SPEC 4925
394700............................. SPEC 4925
394710............................. SPEC 4925
394720............................. SPEC 4925
394730............................. SPEC 4925
394740............................. SPEC 4925
394750............................. SPEC 4925
394760............................. SPEC 4925
394770............................. SPEC 4925
394780............................. SPEC 4925
394790............................. SPEC 4925
394800............................. SPEC 4925
394810............................. SPEC 4925
394820............................. SPEC 4925
394830............................. SPEC 4925
394840............................. SPEC 4925
394850............................. SPEC 4925
394860............................. SPEC 4925
394870............................. SPEC 4925
394880............................. SPEC 4925
394890............................. SPEC 4925
394900............................. SPEC 4925
394910............................. SPEC 4925
394920............................. SPEC 4925
394930............................. SPEC 4950
394940............................. SPEC 4950
394950............................. SPEC 4950
394960............................. SPEC 4925
395070V........................... SPEC 4580
395080V........................... SPEC 4580
395090V........................... SPEC 4580
395100V........................... SPEC 4580
395110V........................... SPEC 4580
395120V........................... SPEC 4580
395130V........................... SPEC 4580
395140V........................... SPEC 4580
395150V........................... SPEC 4580
395160V........................... SPEC 4580
395170V........................... SPEC 4580
395180V........................... SPEC 4580
395190V........................... SPEC 4580
395200V........................... SPEC 4580
395370............................. SPEC 5790
395380............................. SPEC 5790
395390............................. SPEC 5790
395400............................. SPEC 5790
395410............................. SPEC 5880
395420............................. SPEC 5880
395430............................. SPEC 5880
395440............................. SPEC 5880
395450............................. SPEC 5880
395460............................. SPEC 5880
395470............................. SPEC 5880
395480............................. SPEC 5880
395490............................. SPEC 5880
395500............................. SPEC 5880
395510............................. SPEC 5880
395520............................. SPEC 5880
395530............................. SPEC 5890
395540............................. SPEC 5890
395550............................. SPEC 5890
395560............................. SPEC 5890
395570............................. SPEC 5890

395580............................. SPEC 5890
395590............................. SPEC 5890
395600............................. SPEC 5890
395610............................. SPEC 5890
395620............................. SPEC 5890
395630............................. SPEC 5890
395640............................. SPEC 5890
396093............................. SPEC 5200
397310............................. SPEC 4460
397320............................. SPEC 4460
397330............................. SPEC 4460
397340............................. SPEC 4460
397350............................. SPEC 4460
397360............................. SPEC 4460
397370............................. SPEC 4460
397380............................. SPEC 4460
397390............................. SPEC 4460
397400............................. SPEC 4460
397410............................. SPEC 4460
397420............................. SPEC 4460
397430............................. SPEC 4460
397440............................. SPEC 4460
397450............................. SPEC 4460
397460............................. SPEC 4460
397470............................. SPEC 4460
397480............................. SPEC 4460
397490............................. SPEC 4460
397500............................. SPEC 4460
397510............................. SPEC 4460
397520............................. SPEC 4480
397530............................. SPEC 4480
397540............................. SPEC 4480
397550............................. SPEC 4480
397560............................. SPEC 4480
397570............................. SPEC 4480
397580............................. SPEC 4480
397590............................. SPEC 4480
403990............................. SPEC 3300
404000............................. SPEC 3300
404010............................. SPEC 3300
404020............................. SPEC 3300
404030............................. SPEC 3300
404040............................. SPEC 3300
404050............................. SPEC 3300
404060............................. SPEC 3300
404070............................. SPEC 3300
404080............................. SPEC 3300
404090............................. SPEC 3300
404330............................. SPEC 3300
406320............................. SPEC 3300
419630............................. SPEC 3300
434680............................. SPEC 3300
506887M.......................... SPEC 5700
522582M.......................... SPEC 5700
526839M.......................... SPEC 5700
543640............................. SPEC 4800
547230............................. SPEC 4800
554420............................. SPEC 3150
589692M.......................... SPEC 5700
607078M.......................... SPEC 5700
614607M.......................... SPEC 5700
624010............................. SPEC 3150
624740............................. SPEC 3150
624750............................. SPEC 3150
624760............................. SPEC 3150
624780............................. SPEC 3150
624790............................. SPEC 3150
624850............................. SPEC 3150
624860............................. SPEC 3150
624870............................. SPEC 3150
624890............................. SPEC 3150
624900............................. SPEC 3150
624910............................. SPEC 3150

624920............................. SPEC 3150
624950............................. SPEC 3150
624980............................. SPEC 3150
624990............................. SPEC 3150
625000............................. SPEC 3150
625020............................. SPEC 3150
625030............................. SPEC 3150
625040............................. SPEC 3150
625050............................. SPEC 3150
625160............................. SPEC 3150
625200............................. SPEC 3150
625220............................. SPEC 3150
625230............................. SPEC 3150
625250............................. SPEC 3150
625270............................. SPEC 3150
625280............................. SPEC 3150
625290............................. SPEC 3150
647530............................. SPEC 4800
647550............................. SPEC 4800
647560............................. SPEC 4850
647590............................. SPEC 4850
647600............................. SPEC 4850
647650............................. SPEC 4850
650981M.......................... SPEC 5700
686890............................. SPEC 3150
759610............................. SPEC 1250
759770............................. SPEC 1300
759780............................. SPEC 1300
760300............................. SPEC 1350
760420............................. SPEC 1300
760530............................. SPEC 1250
763699M.......................... SPEC 5700
770370............................. SPEC 4500
770380............................. SPEC 4500
770390............................. SPEC 4500
770400............................. SPEC 4500
770410............................. SPEC 4500
770420............................. SPEC 4500
770430............................. SPEC 4500
770450............................. SPEC 4500
770460............................. SPEC 4500
770470............................. SPEC 4500
770480............................. SPEC 4500
770490............................. SPEC 4500
770520............................. SPEC 4500
770530............................. SPEC 4500
770540............................. SPEC 4500
770550............................. SPEC 4500
770560............................. SPEC 4500
770570............................. SPEC 4500
770580............................. SPEC 4500
770590............................. SPEC 4500
770600............................. SPEC 4500
770610............................. SPEC 4500
770670............................. SPEC 4500
770700............................. SPEC 4500
770900............................. SPEC 4500
770950............................. SPEC 4500
771080............................. SPEC 4500
780200............................. SPEC 8075
780210............................. SPEC 8050
780220............................. SPEC 8025
780230............................. SPEC 8075
780240............................. SPEC 8050
780250............................. SPEC 8025
780260............................. SPEC 8150
780270............................. SPEC 8075
780280............................. SPEC 8025
780290............................. SPEC 8025
780310............................. SPEC 8025
780320............................. SPEC 8050
783160............................. SPEC 4550
783190............................. SPEC 4550

783230............................. SPEC 4550
783330............................. SPEC 4550
791720............................. SPEC 1250
792940............................. SPEC 8025
792960............................. SPEC 8025
792980............................. SPEC 8025
793000............................. SPEC 8025
793140............................. SPEC 8125
793160............................. SPEC 8175
793180............................. SPEC 8175
793200............................. SPEC 8150
794520............................. SPEC 8125
794540............................. SPEC 8025
827197M.......................... SPEC 5700
861898M.......................... SPEC 5700
883753M.......................... SPEC 5700
977766M.......................... SPEC 5700

Phone: 888-593-3355
www.generalcable.com

Notes

Phone: 888-593-3355
www.generalcable.com

Notes

Phone: 888-593-3355
www.generalcable.com

UniShield

®

EPR 5-35kV Power Cable
UL Type MV-105

Performance
Beyond Just

Power

Other General Cable Products Offered

COMMODORE®
CATALOG

MOR® POLYRAD®
CATALOG

MV-RIG®
CATALOG

General Cable

CCW®
CATALOG

X-TRACT® ESP
CATALOG

General Cable Canada

4 Tesseneer Drive
Highland Heights,
Kentucky 41076-9753
U.S.A.

Telephone (888) 593-3355
Fax (800) 335-1270
International Telephone +1 905 494 5300
International Fax +1 905 791 5328

156 Parkshore Drive
Brampton, Ontario L6T 5M1
Telephone	 (800) 561-0649
Fax 	
(800) 565-2529

info@generalcable.com

www.generalcable.com

infoca@generalcable.com

Form No. INS-0043-R0613
41809

Use your smartphone to view
Interactive Catalog online



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2013:06:11 07:54:04-04:00
Creator                         : Adobe InDesign CS6 (Macintosh)
Modify Date                     : 2013:12:13 14:22:19-05:00
Title                           : 
Trapped                         : False
Has XFA                         : No
Tagged PDF                      : No
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2013:12:13 14:22:19-05:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Format                          : application/pdf
Document ID                     : uuid:b4f68cd9-ee6e-2047-af27-e975ee9f3ab9
Instance ID                     : uuid:4893ea90-782a-d04c-8185-51527b4f3c12
Producer                        : Adobe PDF Library 10.0.1
Page Layout                     : OneColumn
Page Mode                       : UseOutlines
Page Count                      : 308
EXIF Metadata provided by EXIF.tools

Navigation menu