USER GUIDE 
 

 
 

Digital Light Meter 
 
 
Model LT300 

Introduction 
Congratulations on your purchase of the Extech LT300 Digital Light Meter. The LT300 measures 
light level (illuminance) to 400,000 Lux (40,000 Fc). The LT300 offers a backlit display, MAX/MIN, 
Data Hold, Relative, Peak, and Reset features. This instrument is shipped fully tested and calibrated 
and, with proper use, will provide years of reliable service. Please visit our website 
(www.extech.com) to check for the latest version of this User Guide, Product Updates, and 
Customer Support. 
 
 
 
 

Meter Description 
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.

Sensor cable 
Analog bargraph 
Numerical display 
RANGE button 
ON/OFF button 
MAX/MIN button 
RESET button 
LCD Backlight button 
LUX button 
Fc foot candle button 
Protective rubber jacket 
RELATIVE button 
Data HOLD button 
PEAK button 
Photo sensor dome 

1
2
15

3

4

11

5

12

6

13

7

14

8
9 10

 
 
 
 
Notes: Protective sensor cap not shown. Battery compartment, Tilt Stand, and Tripod Mount 
are located on the rear of the instrument. The protective rubber jacket must be removed 
from meter to access battery compartment. 

2

LT300-EU-EN V2.3 2/13

Operation 
Light sensor 
1. The light sensor is permanently attached to 
the meter by the coiled cable. 
2. Remove the protective cap by unsnapping it 
to expose the white domed light sensor. 
When the sensor’s protective cap is removed, the white domed light sensor lens will begin to 
capture light. Replace the cap when the meter is not in use. 

Turn Power ON or OFF 
Press the        button to turn power on or off. If the display does not switch on, check that the 9V 
battery is installed and is fresh. 

Selecting Lux or Foot candle units of measure 
Press the LUX button to select lux units or the Fc button to select foot candle units. 

Measurement Procedure 
1. Remove the protective cap from the sensor so that the white domed light sensor is exposed 
to the light. For overhead lighting, the sensor can be placed on a desk or table top. A tripod 
mount and a tilt stand are located on the rear of the meter for convenience. 
2. The display will indicate the light level in Fc or Lux.  
3. Press the RANGE button to select the range that provides the maximum resolution. If the 
‘OL’ appears the light measurement is out of range. Select another range using the RANGE 
button.  
4. Press the backlight button to illuminate the LCD display if needed. 

MAX/MIN  
The Max/Min function allows for recording and display of the maximum and minimum light 
levels over time. 
1. Press the MAX/MIN button. The MAX display icon will appear and meter will now display 
and hold only the highest reading. The display will update only when a higher reading is 
measured. 
2. Press MAX/MIN button. The MIN display icon will appear and meter will now display and 
hold only the lowest reading. The display will update only when a lower reading is measured 
3. Press MAX/MIN again. The MAX MIN display icons will appear flashing and meter will now 
display the current reading, but will continue to record the highest and lowest values. 
4. Press MAX/MIN again to cycle through MAX and MIN displays. 
5. To exit the MAX MIN mode, press and hold the MAX/MIN button until the MAX and MIN 
icons completely disappear.  

Data Hold 
Press the HOLD button to freeze the displayed reading. The ” MANU HOLD” hold icon will appear 
on the display. Press the HOLD button again to return to normal operation. When the Data Hold 
function is enabled the analog bar graph will continue to display level changes. 
3

LT300-EU-EN V2.3 2/13

Peak Hold 
The Peak Hold feature allows the meter to captures light pulses that rise or fall down to 10µs.  
1. Press and hold the PEAK button until CAL appears in the display. 
2. Momentarily press the PEAK button. The ‘PMAX’ icon will appear on the LCD. The meter will 
then measure and display any light pulses. The display will hold the results until a higher 
pulse appears.  
3. Press the PEAK button again to display the “PMIN” values. 
4. To exit the Peak Hold mode, press and hold the PEAK button until the ‘PMAX’ or ‘PMIN’ icon 
disappears. 

Relative mode 
Measurements can be displayed as a difference between the measured light level and a stored 
reference value. To store a reading as a reference, press the REL button when the desired 
reference measurement is on the LCD (the REL icon will switch on). All subsequent displayed 
readings will be “relative” to the stored reference value. For example, if the reference value is 
100 and the actual light level is 125, the meter will display 25. To view the reference value, press 
the REL button again so that the REL icon begins to flash. The displayed value will be the 
reference value. To exit the Relative mode, press and hold the REL button until the REL icon 
disappears. 

RESET 
Press the RESET button to clear the memory and exit from REL, HOLD, PEAK and MAX/MIN. The 
RESET will also reset the auto power off timer. 

Backlight 
Press the “      “ button to turn the backlight on. Press again to turn it off. 

4

LT300-EU-EN V2.3 2/13

Maintenance 
Cleaning and storage 
1. The white plastic sensor dome should be cleaned with a damp cloth when necessary. Use 
only a mild soap if needed. Do not use solvents, abrasives, or harsh detergents to clean the 
dome. 
2. Store the meter in an area with moderate temperature and humidity (refer to the operating 
and storage range in the ‘Specifications’ section). 

Battery Replacement 
When the battery power begins to fail the low battery symbol “ ”will appear on the LCD. Replace 
the 9V battery by first removing protective jacket that encases the meter. Remove the rear 
(center) battery compartment screw to access the battery compartment. Ensure that the 
compartment cover is securely fastened and that the protective jacket is properly installed 
before using the meter. 
 
Never dispose of used batteries or rechargeable batteries in household waste. 
As consumers, users are legally required to take used batteries to appropriate 
collection sites, the retail store where the batteries were purchased, or wherever 
batteries are sold. 
Disposal: Do not dispose of this instrument in household waste. The user is 
obligated to take end‐of‐life devices to a designated collection point for the disposal 
of electrical and electronic equipment.  
 
Other Battery Safety Reminders 
o Never dispose of batteries in a fire. Batteries may explode or leak. 
o Never mix battery types. Always install new batteries of the same type. 

5

LT300-EU-EN V2.3 2/13

Specifications 
Ranges and Resolution 

Accuracy 

Lux 
40.00, 400.0, 4000, 40.00k, 400.0kLux 

± (5% Rdg + 0.5% Full Scale) 

Foot candle (Fc) 
40.00, 400.0, 4000, 40.00kFc 

± (5% Rdg + 0.5% Full Scale) 

General Specifications 
Display 

Multi‐function 3‐3/4 (3999) digit LCD with Bargraph indicator 

Over range indication 

LCD displays ‘OL’  

Spectral response 

CIE photopic (CIE human eye response curve) 

Spectral accuracy 

CIE V function (f1  6%) 

Measurement Repeatability 

±2% 

o
Temperature coefficient  ±0.1% per  C 

Sampling rate 

13.3 times per second (bargraph); 1.3 times per second (digital 
display) 

Photo detector 

Silicon photo‐diode with spectral response filter 

Peak Hold 

Capture light peaks to 10µS 

Operating conditions 

o
o
Temperature: 0 to 40 C (32 to 104 F); Humidity: < 80% RH 

Storage conditions 

o
o
Temperature: ‐10 to 50 C (14 to 140 F); Humidity: < 80% RH 

Dimensions 

165 x 76 x 43mm (6.5 x 3.0 x 1.7") 

Weight 

Approx. 403g (14.2 oz.) with battery installed 

Low battery indication 

“ ” appears on the LCD 

Power supply 

9V battery 

 
 
 
 
 
 
 

Copyright © 2013 FLIR Systems, Inc. 
All rights reserved including the right of reproduction in whole or in part in any form 
ISO‐9001 Certified 

www.extech.com 
 
 
 
6

LT300-EU-EN V2.3 2/13

Appendix 
Typical Light Levels 
Lux 
 
20‐75 
75‐150 

Foot 
Candles 
 
2‐7 
7‐15 

150‐300 

15‐30 

300‐750 
750‐1,500 
1,500‐3,000 
 
75‐100 
100‐200 

30‐75 
75‐150 
150‐300 
 
7‐10 
10‐20 

200‐750 

20‐75 

 

Lux 

Factories 
Emergency Stairs, Warehouse  
Exit/Entrance Passages 

 
100‐150 
150‐200 

Packing Work 

200‐300 

Visual Work: Production  Line 
Typesetting: Inspection Work 
Electronic  Assembly, Drafting 
Office 
Indoor Emergency Stairs 
Corridor Stairs 

300‐500 
500‐1,500 
1,000‐2,000 
 
75‐150 
150‐300 

Conference, 
Reception Room 
750‐1,500 
75‐150  Clerical Work 
1,500‐2,000  150‐2000  Typing, Drafting 
 
 
Store 
75‐150 
7‐15 
Indoors 
150‐200 
15‐20  Corridor/Stairs 
200‐300 
20‐30  Reception 
300‐500 
500‐750 
750‐1,500 

300‐750 
750‐1,500 
 
 
30‐75 
75‐100 
100‐150 

30‐50 
50‐75 
75‐150 

Display Stand 
Elevator 
Show Window, 
Packing Table 
150‐300  Storefront, Show Window 

1,500‐3,000 

150‐200 
200‐750 
750‐1,500 
5,000‐10,000

Foot 
Candles 
 
10‐15 
15‐20 

 

Home 
Washing 
Recreational 
Activities 
20‐30  Drawing Room, 
Table 
30‐50  Makeup 
50‐150  Reading, Study 
100‐200  Sewing 
 
Restaurant 
7‐15 
Corridor Stairs 
15‐30  Entrance, 
Wash Room 
30‐75  Cooking Room, 
Dining Table 
75‐150  Show Window 
 
 
 
Hospital 
3‐7 
Emergency Stairs  
7‐10 
Stairs 
10‐15  Sick Room, 
Warehouse 
15‐20  Waiting Room 
20‐75  Medical Exam Room
75‐150  Operating Room 
500‐1000  Eye Inspection 

Spectral Sensitivity 
 

R
e
l
a
t
i
v
e
R
e
s
p
o
n
s
e

1

 

0.8
0.6
0.4
0.2
0 400

450

500

550
600
650
700
Wavelength (nm)
_____
- - - - - Light Meter Response
CIE Response

7

LT300-EU-EN V2.3 2/13



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Administrator
Create Date                     : 2013:03:04 13:40:51-05:00
Modify Date                     : 2013:03:04 13:40:51-05:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Title                           : Microsoft Word - LT300-EU-EN-V2.3.doc
Creator                         : Administrator
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.2.0 (Windows)
Document ID                     : uuid:cf52375e-ce9f-4630-b376-48376171b7ef
Instance ID                     : uuid:fe612038-0a58-44cb-8b90-5d398289db7d
Page Count                      : 7
EXIF Metadata provided by EXIF.tools

Navigation menu