Introduction
CongratulationsonyourpurchaseoftheExtechLT300DigitalLightMeter.TheLT300measures
lightlevel(illuminance)to400,000Lux(40,000Fc).TheLT300offersabacklitdisplay,MAX/MIN,
DataHold,Relative,Peak,andResetfeatures.Thisinstrumentisshippedfullytestedandcalibrated
and,withproperuse,willprovideyearsofreliableservice.Pleasevisitourwebsite
(www.extech.com)tocheckforthelatestversionofthisUserGuide,ProductUpdates,and
CustomerSupport.
MeterDescription
1. Sensorcable
2. Analogbargraph
3. Numericaldisplay
4. RANGEbutton
5. ON/OFFbutton
6. MAX/MINbutton
7. RESETbutton
8. LCDBacklightbutton
9. LUXbutton
10. Fcfootcandlebutton
11. Protectiverubberjacket
12. RELATIVEbutton
13. DataHOLDbutton
14. PEAKbutton
15. Photosensordome
Notes:Protectivesensorcapnotshown.Batterycompartment,TiltStand,andTripodMount
arelocatedontherearoftheinstrument.Theprotectiverubberjacketmustberemoved
frommetertoaccessbatterycompartment.
LT300-EU-EN V2.3 2/13
3
Operation
Lightsensor
1. Thelightsensorispermanentlyattachedto
themeterbythecoiledcable.
2. Removetheprotectivecapbyunsnappingit
toexposethewhitedomedlightsensor.
Whenthesensor’sprotectivecapisremoved,thewhitedomedlightsensorlenswillbeginto
capturelight.Replacethecapwhenthemeterisnotinuse.
TurnPowerONorOFF
Pressthebuttontoturnpoweronoroff.Ifthedisplaydoesnotswitchon,checkthatthe9V
batteryisinstalledandisfresh.
SelectingLuxorFootcandleunitsofmeasure
PresstheLUXbuttontoselectluxunitsortheFcbuttontoselectfootcandleunits.
MeasurementProcedure
1. Removetheprotectivecapfromthesensorsothatthewhitedomedlightsensorisexposed
tothelight.Foroverheadlighting,thesensorcanbeplacedonadeskortabletop.Atripod
mountandatiltstandarelocatedontherearofthemeterforconvenience.
2. ThedisplaywillindicatethelightlevelinFcorLux.
3. PresstheRANGEbuttontoselecttherangethatprovidesthemaximumresolution.Ifthe
‘OL’appearsthelightmeasurementisoutofrange.SelectanotherrangeusingtheRANGE
button.
4. PressthebacklightbuttontoilluminatetheLCDdisplayifneeded.
MAX/MIN
TheMax/Minfunctionallowsforrecordinganddisplayofthemaximumandminimumlight
levelsovertime.
1. PresstheMAX/MINbutton.TheMAXdisplayiconwillappearandmeterwillnowdisplay
andholdonlythehighestreading.Thedisplaywillupdateonlywhenahigherreadingis
measured.
2. PressMAX/MINbutton.TheMINdisplayiconwillappearandmeterwillnowdisplayand
holdonlythelowestreading.Thedisplaywillupdateonlywhenalowerreadingismeasured
3. PressMAX/MINagain.TheMAXMINdisplayiconswillappearflashingandmeterwillnow
displaythecurrentreading,butwillcontinuetorecordthehighestandlowestvalues.
4. PressMAX/MINagaintocyclethroughMAXandMINdisplays.
5. ToexittheMAXMINmode,pressandholdtheMAX/MINbuttonuntiltheMAXandMIN
iconscompletelydisappear.
DataHold
PresstheHOLDbuttontofreezethedisplayedreading.The”MANUHOLD”holdiconwillappear
onthedisplay.PresstheHOLDbuttonagaintoreturntonormaloperation.WhentheDataHold
functionisenabledtheanalogbargraphwillcontinuetodisplaylevelchanges.
LT300-EU-EN V2.3 2/13
4
PeakHold
ThePeakHoldfeatureallowsthemetertocaptureslightpulsesthatriseorfalldownto10µs.
1. PressandholdthePEAKbuttonuntilCALappearsinthedisplay.
2. MomentarilypressthePEAKbutton.The‘PMAX’iconwillappearontheLCD.Themeterwill
thenmeasureanddisplayanylightpulses.Thedisplaywillholdtheresultsuntilahigher
pulseappears.
3. PressthePEAKbuttonagaintodisplaythe“PMIN”values.
4. ToexitthePeakHoldmode,pressandholdthePEAKbuttonuntilthe‘PMAX’or‘PMIN’icon
disappears.
Relativemode
Measurementscanbedisplayedasadifferencebetweenthemeasuredlightlevelandastored
referencevalue.Tostoreareadingasareference,presstheRELbuttonwhenthedesired
referencemeasurementisontheLCD(theRELiconwillswitchon).Allsubsequentdisplayed
readingswillbe“relative”tothestoredreferencevalue.Forexample,ifthereferencevalueis
100andtheactuallightlevelis125,themeterwilldisplay25.Toviewthereferencevalue,press
theRELbuttonagainsothattheRELiconbeginstoflash.Thedisplayedvaluewillbethe
referencevalue.ToexittheRelativemode,pressandholdtheRELbuttonuntiltheRELicon
disappears.
RESET
PresstheRESETbuttontoclearthememoryandexitfromREL,HOLD,PEAKandMAX/MIN.The
RESETwillalsoresettheautopowerofftimer.
Backlight
Pressthe““buttontoturnthebacklighton.Pressagaintoturnitoff.
LT300-EU-EN V2.3 2/13
5
Maintenance
Cleaningandstorage
1. Thewhiteplasticsensordomeshouldbecleanedwithadampclothwhennecessary.Use
onlyamildsoapifneeded.Donotusesolvents,abrasives,orharshdetergentstocleanthe
dome.
2. Storethemeterinanareawithmoderatetemperatureandhumidity(refertotheoperating
andstoragerangeinthe‘Specifications’section).
BatteryReplacement
Whenthebatterypowerbeginstofailthelowbatterysymbol“”willappearontheLCD.Replace
the9Vbatterybyfirstremovingprotectivejacketthatencasesthemeter.Removetherear
(center)batterycompartmentscrewtoaccessthebatterycompartment.Ensurethatthe
compartmentcoverissecurelyfastenedandthattheprotectivejacketisproperlyinstalled
beforeusingthemeter.
Neverdisposeofusedbatteriesorrechargeablebatteriesinhouseholdwaste.
Asconsumers,usersarelegallyrequiredtotakeusedbatteriestoappropriate
collectionsites,theretailstorewherethebatterieswerepurchased,orwherever
batteriesaresold.
Disposal:Donotdisposeofthisinstrumentinhouseholdwaste.Theuseris
obligatedtotakeend‐of‐lifedevicestoadesignatedcollectionpointforthedisposal
ofelectricalandelectronicequipment.
OtherBatterySafetyReminders
o Neverdisposeofbatteriesinafire.Batteriesmayexplodeorleak.
o Nevermixbatterytypes.Alwaysinstallnewbatteriesofthesametype.
LT300-EU-EN V2.3 2/13
6
Specifications
RangesandResolutionAccuracy
Lux
40.00,400.0,4000,40.00k,400.0kLux±(5%Rdg+0.5%FullScale)
Footcandle(Fc)
40.00,400.0,4000,40.00kFc±(5%Rdg+0.5%FullScale)
GeneralSpecifications
DisplayMulti‐function3‐3/4(3999)digitLCDwithBargraphindicator
OverrangeindicationLCDdisplays‘OL’
SpectralresponseCIEphotopic(CIEhumaneyeresponsecurve)
SpectralaccuracyCIEV function(f1 6%)
MeasurementRepeatability±2%
Temperaturecoefficient±0.1%peroC
Samplingrate13.3timespersecond(bargraph);1.3timespersecond(digital
display)
PhotodetectorSiliconphoto‐diodewithspectralresponsefilter
PeakHoldCapturelightpeaksto10µS
OperatingconditionsTemperature:0to40oC(32to104oF);Humidity:<80%RH
StorageconditionsTemperature:‐10to50oC(14to140oF);Humidity:<80%RH
Dimensions165x76x43mm(6.5x3.0x1.7")
WeightApprox.403g(14.2oz.)withbatteryinstalled
Lowbatteryindication“”appearsontheLCD
Powersupply9Vbattery
Copyright©2013FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorinpartinanyform
ISO‐9001Certified
www.extech.com
LT300-EU-EN V2.3 2/13
7
Appendix
TypicalLightLevels
LuxFoot
Candles
LuxFoot
Candles
Factories Home
20‐752‐7EmergencyStairs,Warehouse 100‐15010‐15Washing
75‐1507‐15Exit/EntrancePassages150‐20015‐20Recreational
Activities
150‐30015‐30PackingWork200‐30020‐30DrawingRoom,
Table
300‐75030‐75VisualWork:ProductionLine300‐50030‐50Makeup
750‐1,50075‐150Typesetting:InspectionWork500‐1,50050‐150Reading,Study
1,500‐3,000150‐300ElectronicAssembly,Drafting1,000‐2,000100‐200Sewing
OfficeRestaurant
75‐1007‐10IndoorEmergencyStairs75‐1507‐15CorridorStairs
100‐20010‐20CorridorStairs150‐30015‐30Entrance,
WashRoom
200‐75020‐75Conference,
ReceptionRoom
300‐75030‐75CookingRoom,
DiningTable
750‐1,50075‐150ClericalWork750‐1,50075‐150ShowWindow
1,500‐2,000150‐2000Typing,Drafting
StoreHospital
75‐1507‐15Indoors30‐753‐7EmergencyStairs
150‐20015‐20Corridor/Stairs75‐1007‐10Stairs
200‐30020‐30Reception100‐15010‐15SickRoom,
Warehouse
300‐50030‐50DisplayStand150‐20015‐20WaitingRoom
500‐75050‐75Elevator200‐75020‐75MedicalExamRoom
750‐1,50075‐150ShowWindow,
PackingTable
750‐1,50075‐150OperatingRoom
1,500‐3,000150‐300Storefront,ShowWindow5,000‐10,000 500‐1000EyeInspection
SpectralSensitivity
400 450 500 550 600 650 700
Wavelength (nm)
- - - - - Light Meter Response _____ CIE Response
R
e
l
a
t
i
v
e
R
e
s
p
o
n
s
e
1
0.8
0.6
0.4
0.2
0