Spec Sheet_A4_V__
2014-07-04
: Pdf 673038-Attachment 673038-Attachment 009602 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 31
Download | |
Open PDF In Browser | View PDF |
3 Fibre Termination 3.1. UniCam 3.1.1. UniCam Pretium 3.1.2. UniCam Standard 3.1.3. UniCam 250 μm 3.1.4. UniCam SC-APC 3.1.5. UniCam MTP 3.1.6. UniCam Tool Kit 3.2. Anaerobic 3.2.1. Anaerobic Connectors 3.2.2. Anaerobic Tool Kit 3.3. Furcation Kit 3.3.1. Buffer Tube Fan Out 3.3.2. Ribbon 3.3.3. Spider Fan Out 3.4. Camsplice Data sheet Unicam Pretium SC, ST and LC / November 2008 ® Product Family: LANscape Field Installable Connectors Product: UniCam Pretium ST, SC and LC Connectors Fibre: InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF-28e+™ OS2 ® ® ® ® Description The UniCam® Pretium Connector is the ideal solution for all your field-installable fibre optic connector requirements. The quick installation reduces the total installed cost of connectorization, making the UniCam Connector cost-effective for all fibre applications, from the main cross-connect to the workstation. The UniCam Connector can best be described as a mini pigtail. It incorporates a factory-installed fibre stub that is fully bonded in the ferrule. The other end is precisely cleaved and placed into the patented alignment mechanism of a mechanical splice. Both the field fibre and fibre stub are fully protected from environmental factors. Unlike other no epoxy, fieldinstallable connectors, the UniCam Connector requires no polishing. The unique features of the Unicam are the accuracy of the factory polished end face process, 100% quality control of every connector and the visual feedback system during field installation. Applications All field-installable UniCam® Pretium connector versions provide a high-quality alternative to epoxy and polish connectors. They provide simple, quick and reliable connector installation on site. Fibre stubs are pre-installed in the ferrules of the UniCam connectors at the factory, thus eliminating the critical epoxy and polish operations in the field. This approach also allows the necessary high quality, controlled end face processing to be performed as part of the production process in the factory, thus reducing field technician influence to a minimum. On site, the stripped and cleaved field fibres are inserted into the UniCam connectors and retained. A mechanical splice inside the connector establishes the low-loss connection between the field fibre and the preinstalled fibre inside the connector. Features / Benefits - Fastest termination time in the industry: less than 1 min with single fibre connector - Continuity- Test-Set gives immediate go/no go feedback of successful termination 3-D view from polished end face of a Unicam connector Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Unicam Pretium SC, ST and LC / November 2008 Characteristics Connector type Ferrule Connector body Insertion loss, typical (dB) MM Insertion loss, max. (dB) MM Reflectance Multimode typical (dB) MM PC OM1/OM2 Reflectance Multi Mode typical (dB) MM PC OM3 Insertion loss, typical (dB) SM Insertion loss, max. (dB) SM Reflectance Single-Mode typical (dB) MM UPC Cycling to FOTP-21 ST/PC Ceramic Composite 0.10 0.50 SC/PC Ceramic Composite 0.10 0.50 LC/PC Ceramic Composite 0.10 0.50 -20 -20 -20 -26 -26 -26 0.20 0.50 0.20 0.50 0.20 0.50 -55** -55** -55** 0.2 dB, 500 cycles Max. Tensil load Connector 44N on 2.0mm and 2.8mm Legs / Cable Max. Tensil load Connector 4N on 900µm Legs / Tight Buffer Temperatur in operation -40°C to 75°C Temperature cycling to FOTP-3 IL 0.3 dB, -40 – +75 °C, 21 cycles * The insertion loss values is only for using Unicam Pretium Tool Kit. When using the standard Tool Kit the values are 0,3dB typical and 0.75 maximum. ** Please Note: The reflectance values are for 18° to 26° C Connectors according to standard SC ST compatible LC TIA/EIA 604-3 / IEC 61754-4 TIA/EIA 604-2 / IEC 61754-2 TIA/EIA 604-10A / IEC 61754-20 Connector Identification according to EIA/TIA-568-C.3 Draft 2006 Colour code: OM3 (50 m) OM2 (50 m) OM1 (G62,5µm) OS1/OS2 (E9) UPC Housing Black Black Beige Blue Boot Aqua Black Black Blue Contents Single pack Connector type SC ST compatible LC Connector X X X Crimp ring X X X Boot 900µm X X X Boot 2.0mm X Boot 2.8mm X X X Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Unicam Pretium SC, ST and LC / November 2008 Optical Characteristics of fibres: ® Laser optimised multi-mode fibre 50/125 µm, InfiniCor SX+ OM3 Laser bandwidth at 850 nm: 2000 MHz·km Fibre core diameter: 50.0 + 2.5 µm Fibre meets or exceeds standards: TIA/EIA 492AAAC-A, IEC 60793-2-10 Type A1a.2, ISO/IEC 11801 OM3. Fibre tested using minEMBc method, according to TIA/EIA 455-220, IEC 60793-2-10 Ed 2.0 and IEC 60793-1-49 Ed 2.0. ® Laser optimised multi-mode fibre 50/125 µm, InfiniCor 600 OM2 Laser bandwidth at 850 nm: 585 MHz·km Fibre core diameter: 50.0 + 2.5 µm Fibre meets or exceeds standards: TIA/EIA 492AAAB; IEC 60793-2-10 Type A1a.1; ISO/IEC 11801 OM2. Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41. Laser optimised multi-mode fibre 62.5/125 µm, InfiniCor® 300 OM1 Laser bandwidth at 850 nm: 220 MHz·km Fibre core diameter: 62.5 + 2.5 µm Fibre meets or exceeds standards: TIA/EIA 492AAAA; IEC 60793-2-10 Type A1b.1; ISO/IEC 11801 OM1. Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41. Laser optimised single-mode fibre 9/125 µm, SMF 28e+™ OS2 Mode-Field diameter at 1310: 9.2 + 0.4 µm Mode-Field diameter at 1550: 10.4 + 0.5 µm Fibre meets or exceeds standards: TIA/EIA 492-CAAB, IEC 60793-2-50 Type B1.3, ISO/IEC 11801 OS2, Telcordia GR20. Order information SC Ordering number 95-000-41 95-050-41 95-050-41-X 95-200-42 Description SC Connectors Unicam SC-Connector with Ceramic ferrule, Multimode 62,5µm Unicam SC-Connector with Ceramic ferrule, Multimode 50µm Unicam SC-Connector with Ceramic ferrule, Multimode 50µm Unicam SC/UPC-Connector with Ceramic ferrule, Single-mode 9µm Fibre type OM1 OM2 OM3 OS1/OS2 Description ST Connectors Unicam ST-Connector with Ceramic ferrule, Multimode 62,5µm Unicam ST-Connector with Ceramic ferrule, Multimode 50µm Unicam ST-Connector with Ceramic ferrule, Multimode 50µm Unicam ST/UPC-Connector with Ceramic ferrule, Single-mode 9µm Fibre type OM1 OM2 OM3 OS1/OS2 Description LC Connectors Unicam LC-Connector with Ceramic ferrule, Multimode 62,5µm Unicam LC-Connector with Ceramic ferrule, Multimode 50µm Unicam LC-Connector with Ceramic ferrule, Multimode 50µm Unicam LC-Connector with Ceramic ferrule, Single-mode 9µm Fibre type OM1 OM2 OM3 OS1/OS2 ST Ordering number 95-000-51 95-050-51 95-050-51-X 95-200-52 LC Ordering number 95-000-99 95-050-99 95-050-99-X 95-200-99 Minimum Order Quantity in multiples of 25 pce Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Unicam Classic SC, ST, FC & MT-RJ/ November 2008 ® Product Family: LANscape Field Installable Connectors Product: UniCam Classic ST, SC, FC & MT-RJ Connectors Fibre: InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF-28e+™ OS2 ® ® ® ® Description The UniCam® Standard Connectors are the ideal solution for all your field-installable fibre optic connector requirements. The quick installation reduces the total installed cost of connectorization, making the UniCam Connector cost-effective for all fibre applications, from the main cross-connect to the workstation. The UniCam Connector can best be described as a mini pigtail. It incorporates a factoryinstalled fibre stub that is fully bonded in the ferrule. The other end is precisely cleaved and placed into the patented alignment mechanism of a mechanical splice. Both the field fibre and fibre stub are fully protected from environmental factors. Unlike other no epoxy, field-installable connectors, the UniCam Connector requires no polishing. The unique features of the Unicam are the accuracy of the factory polished end face process, 100% quality control of every connector and the visual feedback system during field installation. Applications The field-installable UniCam® connector versions provide a high-quality alternative to epoxy and polish connectors. They provide simple, quick and reliable connector installation on site. Fibre stubs are preinstalled in the ferrules of the UniCam connectors at the factory, thus eliminating the critical epoxy and polish operations in the field. This approach also allows the necessary high quality, controlled end face processing to be performed as part of the production process in the factory, thus reducing field technician influence to a minimum. On site, the stripped and cleaved field fibres are inserted into the UniCam connectors and retained. A mechanical splice inside the connector establishes the low-loss connection between the field fibre and the preinstalled fibre inside the connector. Features / Benefits - Fastest termination time in the industry: less than 1 min with single fibre connector - Fastest termination time in the industry: less than 3 min with MTRJ connector - Continuity- Test-Set gives immediate go/no go feedback of successful termination - Minimal tool kit, reduced setup time; universal assembly tool terminates all single- and 2-fiber UniCam Connector styles 3-D view from polished endface of a Unicam connector Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Unicam Classic SC, ST, FC & MT-RJ/ November 2008 Characteristics Connector type Connector body Ferrule multimode Insertion loss, typical (dB) MM Insertion loss, max. (dB) MM Reflectance Multimode typical (dB) MM PC OM1/OM2 Reflectance Multi Mode typical (dB) MM PC OM3 Ferrule singlemode Insertion loss, typical (dB) SM Insertion loss, max. (dB) SM Reflectance Single-Mode typical (dB) MM UPC Reflectance Single-Mode typical (dB) MM SPC Cycling to FOTP-21 ST/PC Composite Composite 0.30 0.75 SC/PC Composite Composite 0.30 0.75 FC/PC Composite Ceramic 0.30 0.75 MTRJ Composite Composite 0.30 0.75 -20 -20 -20 -20 - - - -20 Ceramic 0.20* 0.50* Ceramic 0.20* 0.50* Ceramic 0.30 0.75 - - -40** -40** Composite - -55** - -40** - 0.2 dB, 500 cycles Max. Tensil load Connector 44N on 2.0mm and 2.8mm Legs / Cable Max. Tensil load Connector 4N on 900µm Legs / Tight Buffer Temperatur in operation 0°C to 60°C Temperature cycling to FOTP-3 IL 0.3 dB, -40 – +75 °C, 21 cycles * The insertion loss values is only for using Unicam Pretium Tool Kit. When using the standard Tool Kit the values are 0,3dB typical and 0.75 maximum. ** Please Note: The reflectance values are for 18° to 26° C Connectors according to standard TAI/EIA 604-3 / IEC 61754-4 TAI/EIA 604-2 / IEC 61754-2 TAI/EIA 604-4 / IEC 61754-13 TAI/EIA 604-12 / IEC 61754-18 SC ST compatible FC MT-RJ Connector Identification according to EIA/TIA-568-C.3 Draft 2006 Colour code: OM3 (50 m) OM2 (50 m) OS2 (E9) OS1/OS2 (E9) SPC Housing Black Black Blue Blue Boot Aqua Black Blue White Contents Single pack Connector type SC ST compatible FC MT-RJ Connector X X X X Crimp ring X X X X Boot 900µm X X X Boot 2.0mm Boot 2.8mm X X X X Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Unicam Classic SC, ST, FC & MT-RJ/ November 2008 Optical Characteristics of fibres: Laser optimised multi-mode fibre 50/125 µm, InfiniCor® SX+ OM3 Laser bandwidth at 850 nm: 2000 MHz·km Fibre core diameter: 50.0 + 2.5 µm Fibre meets or exceeds standards: TIA/EIA 492AAAC-A, IEC 60793-2-10 Type A1a.2, ISO/IEC 11801 OM3. Fibre tested using minEMBc method, according to TIA/EIA 455-220, IEC 60793-2-10 Ed 2.0 and IEC 60793-1-49 Ed 2.0. ® Laser optimised multi-mode fibre 50/125 µm, InfiniCor 600 OM2 Laser bandwidth at 850 nm: 585 MHz·km Fibre core diameter: 50.0 + 2.5 µm Fibre meets or exceeds standards: TIA/EIA 492AAAB; IEC 60793-2-10 Type A1a.1; ISO/IEC 11801 OM2. Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41. ® Laser optimised multi-mode fibre 62.5/125 µm, InfiniCor 300 OM1 Laser bandwidth at 850 nm: 220 MHz·km Fibre core diameter: 62.5 + 2.5 µm Fibre meets or exceeds standards: TIA/EIA 492AAAA; IEC 60793-2-10 Type A1b.1; ISO/IEC 11801 OM1. Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41. Laser optimised single-mode fibre 9/125 µm, SMF 28e+™ OS2 Mode-Field diameter at 1310: 9.2 + 0.4 µm Mode-Field diameter at 1550: 10.4 + 0.5 µm Fibre meets or exceeds standards: TIA/EIA 492-CAAB, IEC 60793-2-50 Type B1.3, ISO/IEC 11801 OS2, Telcordia GR20. Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Unicam Classic SC, ST, FC & MT-RJ/ November 2008 Order Information SC Ordering number 95-000-40 95-050-40 95-200-41 Description SC Connectors Unicam SC-Connector with composite ferrule, Multimode 62,5µm Unicam SC-Connector with composite ferrule, Multimode 50µm Unicam SC/SPC-Connector with Ceramic ferrule, Single-mode 9µm Fibre type OM1 OM2 OS1/OS2 Description ST Connectors Unicam ST-Connector with composite ferrule, Multimode 62,5µm Unicam ST-Connector with composite ferrule, Multimode 50µm Unicam ST/SPC-Connector with Ceramic ferrule, Single-mode 9µm Fibre type OM1 OM2 OS1/OS2 ST Ordering number 95-000-50 95-050-50 95-200-51 FC Description FC Connectors Ordering number 95-000-61 Unicam FC-Connector with Ceramic ferrule, Multimode 62,5µm 95-200-61 Unicam FC-Connector with Ceramic ferrule, Single-mode 9µm 95-200-62 Unicam FC-Connector with Ceramic ferrule, Single-mode 9µm *Please Note: This Connector may not be used with Unicam Pretium Tool Kit Fibre type OM1 OS1/OS2 OS1/OS2 MT-RJ with Pins Ordering number Description MT-RJ Connectors with pins 92-001-97-P-E Unicam MT-RJ Connector with pins Composite ferrule, Multimode 62,5µm 92-051-97-P-E Unicam MT-RJ Connector with pins Composite ferrule, Multimode 50µm 92-051-97-P-E-X Unicam MT-RJ Connector with pins Composite ferrule, Multimode 50µm *Please Note: This Connector may not be used with Unicam Pretium Tool Kit Fibre type OM1 OM2 OM3 MT-RJ without Pins Ordering number Description MT-RJ Connectors without pins Unicam MT-RJ Connector without pins Composite ferrule, Multimode 62,5µm 92-001-97-NP-E Unicam MT-RJ Connector without pins Composite ferrule, Multimode 50µm 92-051-97-NP-E Unicam MT-RJ Connector without pins Composite ferrule, Multimode 50µm 92-051-97-NP-E-X *Please Note: This Connector may not be used with Unicam Pretium Tool Kit Fibre type OM1 OM2 OM3 Minimum Order Quantity in multiples of 25 pce Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Unicam 250µm Pretium SC, LC / November 2008 Product Family: ® LANscape Field Installable Connectors ® TM Product: UniCam 250µm Pretium Fibre: InfiniCor OM3, InfiniCor OM2, InfiniCor OM1, SMF-28+™ OS2 ® SC and LC connectors ® Description The UniCam® 250µm connector is the ideal solution for field-installable fibre optic connector requirements on 250µm bare fibres. The quick installation reduces the total installed cost of connectorization, making the UniCam connector cost-effective for all fibre applications, from the main cross-connect to the workstation. The UniCam connector can best be described as a mini pigtail. It incorporates a factoryinstalled fibre stub that is fully bonded in the ferrule. The other end is precisely cleaved and placed into the patented alignment mechanism of a mechanical splice. Both the field fibre and fibre stub are fully protected from environmental factors. Unlike other no-epoxy, field-installable connectors requires the UniCam connector no polishing. ® Pre-assembled fibre Field insert fibre The unique features of the Unicam are the accuracy of the factory polished end face process, 100% quality control of every connector and the visual go/no go feedback system during field installation. Applications The field-installable UniCam® 250µm connector versions provide a high-quality, quick and reliable connector installation on site. The direct termination on loose- or central tube cables with standard 250µm fibres do not require additional accessories. The high quality end face, controlled during the production process in the factory, reduces field technician influence to a minimum. On site, the stripped and cleaved field fibres are inserted into the UniCam connectors and retained. A mechanical splice inside the connector establishes the low-loss connection between the field fibre and the preinstalled fibre inside the connector. Cam splice Factory-made high-performance polishing Features / Benefits - Fastest termination time in the industry: Less than 1 min with single fibre possible - Pretium Tool Kit gives immediate go/no go feedback of successful termination - Minimal Unicam Pretium Tool Kit allows reduced setup time; universal assembly tool terminates all LC and SC UniCam Connector directly on 250µm bare fibres - Dimensions for fibre preparation are printed on the connector kit package 3-D view from polished endface of a Unicam connector Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Unicam 250µm Pretium SC, LC / November 2008 Characteristics Connector type Ferrule Connector body Insertion loss*, typical (dB) MM Insertion loss*, maximum (dB) MM Reflectance**Multimode typical (dB) MM/PC OM1/OM2 Reflectance** Multi Mode typical (dB) MM/PC OM3 Insertion loss*, typical (dB) SM* Insertion loss*, maximum (dB) SM* Reflectance**Single-Mode typical (dB) SM/UPC OS2 Cycling to FOTP-21 SC Ceramic Composite 0.1* 0.5* LC Ceramic Composite 0.1* 0.5* -20 -20 -26 -26 0.2 0.5 0.2 0.5 -55** -55** 0.2 dB, 500 cycles Max. Tensil load Connector 2N on 250µm Bare fibre with 0.2 change Temperatur in operation -40°C to 75°C Temperature cycling to FOTP-3 IL 0.3 dB, -40 – +75 °C, 21 cycles * The insertion loss values is only for using Unicam Pretium Tool Kit. When using the standard Tool Kit the values are 0,3dB typical and 0.75 maximum. ** Please Note: The reflectance values are for 18° to 26° C Connectors according to standard SC LC TAI/EIA 604-3 / IEC 61754-4 TAI/EIA 604-10A / IEC 61754-20 Connector Identification according to EIA/TIA-568-C.3 Draft 2006 Colour code: OM3 (50 m) OM2 (50 m) OM1 (62.5 m) OS2 (E9) UPC Housing Black Black Beige Blue Boot Aqua Black Beige Blue Contents Single pack Connector type SC LC Connector / Housing / Dust cab X X Tube Boot 900µm X X X X Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Unicam 250µm Pretium SC, LC / November 2008 Optical Characteristics of fibres: Laser optimised multi-mode fibre 50/125 µm, InfiniCor® OM3 Laser bandwidth at 850 nm: 2000 MHz·km Fibre core diameter: 50.0 + 2.5 µm Fibre meets or exceeds standards: TIA/EIA 492AAAC-A, IEC 60793-2-10 Type A1a.2, ISO/IEC 11801 OM3. Fibre tested using minEMBc method, according to TIA/EIA 455-220, IEC 60793-2-10 Ed 2.0 and IEC 60793-1-49 Ed 2.0. ® Laser optimised multi-mode fibre 50/125 µm, InfiniCor OM2 Laser bandwidth at 850 nm: 585 MHz·km Fibre core diameter: 50.0 + 2.5 µm Fibre meets or exceeds standards: TIA/EIA 492AAAB; IEC 60793-2-10 Type A1a.1; ISO/IEC 11801 OM2. Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41. ® Laser optimised multi-mode fibre 62.5/125 µm, InfiniCor OM1 Laser bandwidth at 850 nm: 220 MHz·km Fibre core diameter: 62.5 + 2.5 µm Fibre meets or exceeds standards: TIA/EIA 492AAAA; IEC 60793-2-10 Type A1b.1; ISO/IEC 11801 OM1. Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41. Laser optimised single-mode fibre 9/125 µm, SMF 28e+™ OS2 Mode-Field diameter at 1310: 9.2 + 0.4 µm Mode-Field diameter at 1550: 10.4 + 0.5 µm Fibre meets or exceeds standards: TIA/EIA 492-CAAB, IEC 60793-2-50 Type B1.3, ISO/IEC 11801 OS2, Telcordia GR20. Order information TM SC Pretium Ordering number 95-000-41P 95-050-41P 95-050-41P-X 95-200-42P Description SC Connectors Unicam SC-Connector with Ceramic ferrule, Multimode 62,5µm Unicam SC-Connector with Ceramic ferrule, Multimode 50µm Unicam SC-Connector with Ceramic ferrule, Multimode 50µm Unicam SC/UPC-Connector with Ceramic ferrule, Single-mode 9µm Fibre type OM1 OM2 OM3 OS2 Description LC Connectors Unicam LC-Connector with Ceramic ferrule, Multimode 62,5µm Unicam LC-Connector with Ceramic ferrule, Multimode 50µm Unicam LC-Connector with Ceramic ferrule, Multimode 50µm Unicam LC/UPC-Connector with Ceramic ferrule, Single-mode 9µm Fibre type OM1 OM2 OM3 OS2 LC PretiumTM Ordering number 95-000-99P 95-050-99P 95-050-99P-X 95-200-99P Minimum Order Quantity in multiples of 25 pce Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet UniCam Pretium SC/APC / October 2008 ® Product Family: LANscape Field Installable Connectors Product: UniCam Pretium SC - APC connectors (Pretium Tool Compliant) Fibre: SMF-28+™ OS2 ® Description The field-installable UniCam® APC connector is the ideal solution to minimize back reflectance from laser sources, a critical requirement for applications such as analogue video. UniCam APC Connectors, with their 8º angled end-face and factory polish, dramatically reduce reflectance. The quick installation reduces the total installed cost of connectorization, making the UniCam connector cost-effective for all fibre applications, from the main cross-connect to the workstation. The UniCam connector can best be described as a mini pigtail. It incorporates a factoryinstalled fibre stub that is fully bonded in the ferrule. The other end is precisely cleaved and placed into the patented alignment mechanism of a mechanical splice. Both the field fibre and fibre stub are fully protected from environmental factors. Unlike other no-epoxy, field-installable connectors requires the UniCam connector no polishing. Pre-assembled fibre Field insert fibre The unique features of the UniCam are the accuracy of the factory polished end face process, 100% quality control of every connector and the visual go/no go feedback system during field installation. Applications The field-installable UniCam® APC connector versions provide a high-quality, quick and reliable connector installation on site. The direct termination on tight buffer, loose- or central tube cables do not require any additional accessories. The high quality end face, controlled during the production process in the factory, reduces field technician influence to a minimum. On site, the stripped and cleaved field fibres are inserted into the UniCam connectors and retained. A mechanical splice inside the connector establishes the low-loss connection between the field fibre and the preinstalled fibre inside the connector. Cam splice Factory-made high-performance polishing Features / Benefits - Fastest termination time in the industry: Less than 1 min with single fibre possible - Pretium Tool Kit gives immediate go/no go feedback of successful termination - Minimal UniCam Pretium Tool Kit allows reduced setup time; universal assembly tool terminates all SC UniCam Connector directly on 250µm bare fibres or tight buffer - Dimensions for fibre preparation are printed on the connector kit package Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet UniCam Pretium SC/APC / October 2008 Characteristics Connector type Ferrule Connector body Insertion loss, typical (dB) at 18 - 26° Insertion loss, maximum (dB) at 0° - 60° Reflectance typical (dB) at 18 - 26° Reflectance maximum (dB) at 0° - 60° Cycling to FOTP-21 Max. Tensile load Connector Temperature in operation SC/APC Ceramic Composite 0.40 0.75 -60 -40 0.2 dB, 500 cycles 0.2 change 2N on 250µm Bare fibre, 4N on 900um, 44N on cable 0°C to 60°C , meets TIA/EIA 568-B.3 *Please Note: This values are only valid when utilizing the FBC-015 cleaver (blue). Cleaving values: 1° +/- 1° Connectors according to standard SC TAI/EIA 604-3 / IEC 61754-4 Connector Identification according to EIA/TIA-568-C.3 Draft 2006 Colour code: OS2 (E9) APC Housing Green Boot Green Contents Single pack Connector type SC/APC SC/APC 250 Connector / Housing / Dust cab X X Tube Boot 900µm X X X Boot 2.0mm Boot 2.9mm X Optical Characteristics of fibres: Laser optimised single-mode fibre 9/125 µm, SMF 28+™ OS2 Mode-Field diameter at 1310: 9.2 + 0.4 µm Mode-Field diameter at 1550: 10.4 + 0.5 µm Fibre meets or exceeds standards: TIA/EIA 492-CAAB, IEC 60793-2-50 Type B1.3, ISO/IEC 11801 OS2, Telcordia GR20. Order information TM SC Pretium Ordering number 95-200-44 95-200-44-Z 95-200-44P 95-200-44P-Z Description SC Connectors UniCam SC/APC-Connector with Ceramic ferrule, single pack UniCam SC/APC-Connector with Ceramic ferrule, organizer pack UniCam SC/APC-250µm Connector with Ceramic ferrule, single pack UniCam SC/APC-250µm Connector with Ceramic ferrule, organizer pack Fibre type OS2 OS2 OS2 OS2 Minimum Order Quantity in multiples of 25 pce Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Unicam MTP/ November 2008 ® Product Family: LANscape Field Installable Connectors Product: UniCam MTP connectors Fibre: InfiniCor OM3, InfiniCor OM2, InfiniCor OM1, SMF-28+e™ OS2 ® ® ® ® Description The Corning Cable Systems UniCam® MTP® Connector is the latest innovation in the proven UniCam Connector family. It is the first no epoxy / no-polish, field-installable 12-fibre connector in the industry. It is the ideal solution for applications using 12-fibre ribbons. The UniCam MTP Connector utilizes the same reliable, proven no-epoxy/no polish technology as all other Corning Cable Systems UniCam Connectors. The UniCam MTP Connector installs with the same push-pull reliability as the familiar SC connector. Application The field-installable UniCam MTP connector versions provide simple, quick and reliable connector installation on site. Fibre stubs are preinstalled in the ferrules of the UniCam connectors at the factory, thus eliminating the critical epoxy and polish operations in the field. On site, the stripped and cleaved field fibres are inserted into the UniCam MTP connectors and retained. A mechanical splice inside the connector establishes the low-loss connection between the field fibre and the preinstalled fibre inside the connector. The UniCam MTP connector is installable on bare ribbon or ribbon interconnect cables. Features / Benefits - Repair of Plug & Play™ Systems trunk cables - Terminates jacketed or bare 12-fiber ribbons in less than five minutes - Alignment achieved with precision guide pins - IEEE-802.3, Fibre Channel and ANSI/TIA/EIA-568 B.3 compliant C o r n i n g C a b l e S y s t e m s G m b H & C o . K G · L e i p z i g e r S t r a s s e 1 2 1 · 1 0 11 7 B e r l i n , G e r m a n y T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2008Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Unicam MTP/ November 2008 Characteristics Parameter: Multimode & Single-Mode Standard TAI/EIA 604-5 Insertion loss, typical (dB ≤ 0.5 dB typ. ≤ 1.0 dB max. Reflectance Multi Mode typical ≤ -20dB for Ultra PC (dB) MM PC OM3 Reflectance Single-Mode typical ≤ -55dB for Ultra APC (dB) MM PC OS2 Cycling to FOTP-21 ≤ 0.2 dB, 200 cycles Max. Tensil load Connector ≤10N Ribbon Inter connect Temperature cycling to FOTP-3 IL 0.3 dB, -40 – +75 °C, 21 cycles * Please Note: The reflectance values are for 18° to 28° Optical Characteristics of fibres: ® Laser optimised multimode fibre 50/125 µm, InfiniCor OM3 Laser bandwidth at 850 nm: 2000 MHz·km Fibre core diameter: 50.0 + 2.5 µm Fibre meets or exceeds standards: TIA/EIA 492AAAC-A, IEC 60793-2-10 Type A1a.2, ISO/IEC 11801 OM3. Fibre tested using minEMBc method, according to TIA/EIA 455-220, IEC 60793-2-10 Ed 2.0 and IEC 60793-1-49 Ed 2.0. ® Laser optimised multimode fibre 50/125 µm, InfiniCor OM2 Laser bandwidth at 850 nm: 585 MHz·km Fibre core diameter: 50.0 + 2.5 µm Fibre meets or exceeds standards: TIA/EIA 492AAAB; IEC 60793-2-10 Type A1a.1; ISO/IEC 11801 OM2. Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41. ® Laser optimised multimode fibre 62.5/125 µm, InfiniCor OM1 Laser bandwidth at 850 nm: 220 MHz·km Fibre core diameter: 62.5 + 2.5 µm Fibre meets or exceeds standards: TIA/EIA 492AAAA; IEC 60793-2-10 Type A1b.1; ISO/IEC 11801 OM1. Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41. Laser optimised single-mode fibre 9/125 µm, SMF 28e+™ OS2 Mode-Field diameter at 1310: 9.2 + 0.4 µm Mode-Field diameter at 1550: 10.4 + 0.5 µm Fibre meets or exceeds standards: TIA/EIA 492-CAAB, IEC 60793-2-50 Type B1.3, ISO/IEC 11801 OS2, Telcordia GR20. Order information Ordering number Fibre type Ferrule 93-001-69 62.5µ/OM1 93-051-69 50µ/OM2 93-051-69-X 50µ/OM3 93-201-69 9µ/OS2 93-001-70 62.5µ/OM1 Composite with pins 93-051-70 50µ/OM2 93-051-70-X 93-201-70 Housing Colour housing Colour boot Composite without pins Composite Beige Beige Composite without pins Composite Black Black Composite without pins Composite Black Aqua Composite without pins Composite Black/Green Green Composite Beige Beige Composite with pins Composite Black Black 50µ/OM3 Composite with pins Composite Black Aqua 9µ/OS2 Composite with pins Composite Black/Green Green Quantity per delivery unit: 1/1 C o r n i n g C a b l e S y s t e m s G m b H & C o . K G · L e i p z i g e r S t r a s s e 1 2 1 · 1 0 11 7 B e r l i n , G e r m a n y T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2008Corning Cable Systems. All rights reserved. Published in the EU. Data sheet ® UniCam Single and Two Fibre Connector Tool Kits/ May 2009 ® Product Family: LANscape Field Installable Connectors Tool-Kits Product: UniCam Single Fibre Connectors Tool-Kits Fibre: OM3 Pretium™ 300, OM2 Pretium™ 150, InfiniCor 300 OM1, SMF-28e™ OS1/OS2 ® ® Applications ® The Corning Cable Systems’ UniCam tool-kits are intended for the installation of all Corning Cable ® Systems’UniCam connectors. Tool kits with different equipment are available also for installation of a special group of connectors. Description Corning Cable Systems’tool kits for field installable connectors provide with a collection of essential tools required for tasks associated with the termination of fibre optic cable. The tools are thoughtfully assembled and are stored in compact and easy to carry cases that are lined with a foam-padding material in order to protect the high-quality tools. ® UniCam Pretium Tool Kit The TKT-UNICAM-PFC includes a lightweight, handheld installation tool with an immediate go/no-go feedback signal, providing unmistakable confirmation of a successful termination. The kit’ s high-performance cleaver has an integrated fibre scrap bin and a dualclamp precision hold for the field fibre, with a diamond blade to achieve a superior cleave. The UniCam Pretium Tool Kit can be used with multimode or singlemode LC, SC and ST® Compatible UniCam Connectors (standard and Pretium-performance), and is required to achieve Pretium-Performance specifications for UniCam Pretium-Performance singlemode Connectors. ® The classic UniCam Connector Installation Tool Kit (TKT-UNICAM) is a basic installation tool kit and can be used to terminate all single- UniCam Connector styles (SC, LC and ST compatible). UniCam Multimode Connectors (SC, LC and ST compatible) can achieve high-performance with the use of this tool. The UniCam Connector Installation Tool Kit with Continuity Test Set (TKT-UNICAM-CTS) provides a visual feedback feature when terminating UniCam SC, LC or ST Compatible Connectors. Useful for reducing scrap rates or for training new installers, the TKTUNICAM-CTS-SF is very popular, since the installer can watch for the red glow in the back of the connector to dim or disappear. This indicates that the field fibre is inserted properly in the connector. UniCam CTS-SF Tool Kit UniCam® Basic Tool Kit Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2009 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet ® UniCam Single and Two Fibre Connector Tool Kits/ May 2009 Features / Benefits UniCam® Pretium™ Tool Kit (TKT-UNICAM-PFC) − − − − − − − Virtually eliminates human variability in installation, ensuring consistent, reliable results UniCam Pretium Installation Tool uses a go/no go LED to provide unmistakable confirmation of a successful termination Pretium Cleaver uses dual-clamp precision and a diamond blade for a superior cleave About 60 seconds per connector to install Sleek, well-organized carrying case with built-in conveniences for easy, on-the-go field terminations. Tool kit designed to allow work out of the bag, eliminating set-up and tear-down time One kit terminates both singlemode and multimode LC, SC and ST® Compatible Connectors UniCam Pretium Handheld Tool Kit Standard UniCam SF Connector Installation Tool Kit with Continuity Test Set (TKT-UNICAM-CTS-SF) − − − − Convenient carrying bag contains all of the components necessary to terminate UniCam Connectors Installs SC, LC and ST compatible connectors in less than two minutes One kit terminates singlemode and multimode UniCam Connectors CTS option reduces scrap rate and helps train new installers Pretium Cleaver Standard UniCam Connector Installation Tool Kit (TKT-UNICAM) − − − Convenient carrying bag contains all of the components necessary to terminate UniCam Connectors Installs SC, LC and ST compatible connectors in less than two minutes One kit terminates singlemode and multimode UniCam Elite Installation Cleaver 1-2 Fibers FBC-001 Standard Score and Snap Cleaver Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2009 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet ® UniCam Single and Two Fibre Connector Tool Kits/ May 2009 Tool kits contents Item Pretium UniCam ® installation tool with integrated CTS UniCam Standard Installation Tool UniCam® CTS-SF complete VFL SC and ST® Compatible 2.5 mm LC Compatible 1.25 mm Pretium Flat Cleaver with Diamond Blade and Built-In Fibre Scrap Container Fibre cleaver, score & snap ® Crimp tool, UniCam aramide Stripper 6”wire Jensen tool “Dual-Hole”Miller Tool Fibre Stripper (for 900 m and 250 m fibre) Scissors 5”electrician Tweezers Wipes alcohol Retractable Permanent Marker Standard Capped Permanent SC and ST Compatible 2.5 mm Ferrule Cleaning Sticks (10/pack) LC 1.25 mm Ferrule Cleaning Sticks (10/pack) Package of Corning Wipes (1Pak = 90sheets ) Bottle of Corning Fibre Cleaning Fluid Electrical Tape,black UniCam Pretium Tool Bag with Integrated Waste Receptacle and Organized Foam Insert Interior Standard UniCam Tool Bag Item code PFC CTS-SF Basic TL-UCP 1 pce - - TL-UC01 TEST-UNICAM-CTS-SF VFL-350 VFL-A250 VFL-A125 1 pce 1 pce 1 pce 1 Set 1 pce - 1 pce - FBC-15 1 pce - - FBC-001 3201007-01 3206001-01 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 2104502-01 1 pce 1 pce 1 pce 100294-01 100312-01 1508001-01 Not sold separately Not sold separately 1 pce 1 pce 1 Pack a 10pce 1 Pack a 10pce 1 pce 1 pce 6 pce 1 pce 1 pce 1 pce 6 pce 1 pce - - - - 2104493-01 1 pce - - FCC-Cleaner-Fiber 1 pce - - 2104282-01 - 1 pce 1 pce 02-001860-001 1 pce - - 2104407-01 - 1 pce 1 pce 2104255-01 2104417-01 Ordering information: Type Description UniCam Pretium tool kit Quantity/deliver unit Ordering number UniCam CTS-SF tool kit UniCam basic tool kit 1/1 1/1 1/1 TKT-UNICAM-PFC TKT-UNICAM-CTS-SF TKT-UNICAM Optional accessories: Item CTS adapter for UniCam® SC connectors CTS adapter for UniCam® ST® compatible connectors CTS adapter for UniCam® LC connectors Jumper ST® compatible to SC SM simplex, 1m, FRNC Jumper ST® compatible to LC SM simplex, 1m, FRNC Item code TER-CTS-SC TER-CTS-ST TER-CTS-LC 586101R3Z31001M 026101R2Z31001M CTS 3 pcs 3 pcs 3 pcs 1 pce 1 pce CTS-SF 3 pce 3 pcs 3 pcs 1 pce 1 pce Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2009 Corning Cable Systems. All rights reserved. Published in the EU. Datasheet ® Anaerobic ST compatible, FC, SC, LC/ January 2007 Product Family: LANscape® Field installable connectors Product: ST® compatible, FC, SC and LC anaerobic-cure connectors Fibre: InfiniCor® SX+ OM3, InfiniCor® 600 OM2, InfiniCor® 300 OM1, SMF-28e™ OS2 Applications The Corning Cable Systems’ anaerobic-cure all ceramic ST® compatible, FC, SC and LC connectors are ideal for all applications requiring field installed connectors, like fibre-to-the-desk, fibre-to-the-machine and enterprise networks installations. Description The Corning Cable Systems’ anaerobic-cure multimode and single-mode connectors combine the quick-cure convenience of anaerobic adhesive with the performances of epoxy and polish connectors. The anaerobic adhesive uses a two-part epoxy-resin curing process. The adhesive is first injected into the connector’s ferrule, the fibre is dipped into the primer and inserted into the ferrule, curing takes one minute without the use of UV lamps or ovens. Anaerobic connectors can be completely assembled and polished in less than three minutes. ST® compatible anaerobic-cure connector MM 50/125µm OM2 Features /Benefits - Fast cure anaerobic adhesive: does not require electrical power supply. Minimal tools required. Hand polish: does not require polishing machine. Reduced installation time: < 3 minutes (assembled and polished) Typical insertion loss: 0.2 dB with physical contact polish. ST® compatible, FC, SC connectors delivered in single connector’s bags including connector body with preassembled ferrule, boots for 900 µm fibres and 2-mm, 3-mm jacketed cables, crimp rings for 2-mm, 3-mm jacketed cables. - LC connectors delivered in single connector’s bags including connector body with preassembled ferrule, boots for 900 µm fibres and 2-mm, 3-mm jacketed cables, crimp rings for 1.6 – 2-mm, 3-mm jacketed cables. - Available in 3 versions: MM OM3/OM2: pack includes 2 sets of boots (Aqua OM3, Black OM2 to EIA/TIA-568-C.3 Draft 2006) MM OM1: pack includes 1 set of boots (Beige to EIA/TIA-568-C.3 Draft 2006) SM: pack includes 1 set of boots (Blue to EIA/TIA-568-C.3 Draft 2006 for LC connectors)* - ST® compatible to TIA/EIA 604-2, FC to TIA/EIA 604-4, SC to TIA/EIA 604-3 and LC to TIA/EIA 604-10 ® * Boots for ST compatible, FC and SC single-mode connectors are white. Characteristics Connector type Ferrule Connector body Insertion loss, typical PC (dB) Reflectance Multi Mode (dB) Reflectance SingleMode (dB) Temperature cycling to FOTP-3 ST® comp./PC Ceramic Metal FC/PC Ceramic Metal SC/PC Ceramic Composite LC/PC Ceramic Composite 0.2 ≤ -26 ≤ -40 ∆IL ≤ 0.3 dB, -40 – +75 °C, 21 cycles C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Datasheet ® Anaerobic ST compatible, FC, SC, LC/ January 2007 Ordering information: Multimode connectors ST® compatible Ordering number 95-051-52-SP 95-101-52-SP Description ST® compatible MM Anaerobic, metal housing, black + aqua boots ST® compatible MM Anaerobic, metal housing, beige boots Fibre type OM3/OM2 OM1 FC Ordering number 95-051-61-SP 95-101-61-SP Description FC MM Anaerobic, metal housing, black + aqua boots FC MM Anaerobic, metal housing, beige boots Fibre type OM3/OM2 OM1 SC Ordering number 95-051-41-SP 95-101-41-SP Description SC MM Anaerobic, black housing, black + aqua boots SC MM Anaerobic, beige housing, beige boots Fibre type OM3/OM2 OM1 LC Ordering number 95-051-98-SP 95-101-98-SP Description LC MM Anaerobic, black housing, black + aqua boots LC MM Anaerobic, beige housing, beige boots Fibre type OM3/OM2 OM1 Ordering information: Single-mode connectors ST® compatible Ordering number 95-201-52-SP Description ST® compatible SM Anaerobic, metal housing, white boots Fibre type OS2 FC Ordering number 95-201-61-SP Description FC SM Anaerobic, metal housing, blue boots Fibre type OS2 SC Ordering number 95-201-41-SP Description SC SM Anaerobic, blue housing, blue boots Fibre type OS2 LC Ordering number 95-201-98-SP Description LC SM Anaerobic, blue housing, blue boots Fibre type OS2 C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Anaerobic connector tool kits/ February 2009 ® Product Family: LANscape field installable connectors tool-kits Product: Anaerobic-cure connectors tool-kits Fibre: All Fibre Types Applications The Corning Cable Systems’ Anaerobic tool-kits are intended for the installation of all Corning Cable Systems’Anaerobic and Anaerobic GIC connectors. Tool kits with different equipment are available also for installation of a special group of connectors. Description Corning Cable Systems’tool kits for field installable connectors provide with a collection of essential tools required for tasks associated with the termination of fibre optic cable. The tools are thoughtfully assembled and are stored in compact and easy to carry cases that are lined with a foam-padding material in order to protect the high-quality tools. The standard tool kit (TKT-ANAEROBIC2-EMEA) TKT-ANAEROBIC2-EMEA tool kit allows installation and polishing of multimode and (Adhesive bottles may differ from photo) single-mode all-ceramic anaerobic connectors as well as of the anaerobic GIC connectors. All CCS’anaerobic connector types can be installed with this kit: ST® compatible, FC, SC and LC. The kit contains consumables for up to 500 connectors. The TKT-ANAEROBIC2-25-EMEA is an economical alternative for installation of the only connectors with 2.5 mm diameter ferrules (ST® compatible, FC and SC). The kit contains consumables for up to 500 connectors. The LC supplement kit TKT-ANAEROBIC2-S integrates the TKT-ANAEROBIC2-25-EMEA kit with the additional tools necessary for LC termination. The combined features of TKT-ANAEROBIC2-25-EMEA and TKT-ANAEROBIC2-S are equivalent to those of TKT-ANAEROBIC2-EMEA. A consumables set (TKT-ANAEROBIC2-C-EMEA) is available for replacing consumable materials like polishing films and two components adhesive. The kit contains consumables for up to 500 connectors. Features/Benefits − − − − − Compact and practical carrying bag Full in-depth instruction included All components necessary to install Anaerobic and Anaerobic GIC connectors are included. Each of the tool kit includes consumables for the installation of up to 500 connectors A consumables set including consumables for the installation of up to 500 connectors is available. Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Anaerobic connector tool kits/ February 2009 Tool kits contents Item Loctite#648 anaerobic adhesive, 50ml Loctite #7649 Primer anaerobic, spray, 150ml Syringe 3cc Syringe tip 1.5mm Polishing film clear, 0.2µm, 5” Polishing film grey, 3µm, 6” Polishing film yellow, 12µm, 5” Polishing film white, 0.3µm, 5” Puck polish. SC/ST/FC conn. Puck-LC hand, spring loaded Plate-polish. 6x6”(GIC conn.) Pad rubber (all-cer. Conn.) Crimp tool SC/ST/FC single step Crimp tool LC Scribe, ruby (reversible blade) Stripper 6”wire Jensen tool Stripper, No-nicks, 203µm Fibre stripper, plier type Gauge LC strip length Gauge GIC RPP ST/SC strip length Razor blade single edge Compressed air Scissors 5”electrician Tweezers Wipes alcohol Lint free wipes Marker black 200x microscope 2.5 univ.adp 1.25 univ.adp for microscope Battery 1.5V for microscope Bottle 2.0 oz. with cap Box, plastic clear Spiral wrap 1/8”o.d. Anaerobic procedure ISS 2 Item code TKTTKTANAEROBIC2- ANAEROBIC2-CEMEA EMEA 1pc 1pc TKTANAEROBIC225-EMEA 1pc TKTANAEROBIC2-S - 1pc 1pc 1pc - 100335-01 2104090-01 1506069-01 2 pcs 20 pcs 1 Pack / 50 pcs 1 Pack / 50 pcs 2 pcs 20 pcs 1 Pack / 50 pcs - 2104004-02 2104071-01 1 Pack / 50 pcs 1 Pack / 15 pcs 1 Pack / 50 pcs 1 Pack / 15 pcs 1 Pack / 50 pcs 1 Pack / 15 pcs - 2104072-01 1 Pack / 50 pcs 1 Pack / 50 pcs 1 Pack / 50 pcs - 2104020-01 2104459-01 2104306-01 2 pcs 1 pce 2 pcs - 2 pcs 2 pcs 1 pce - 2104454-01 3201031-01 3 pcs 1 pce - 3 pcs 1 pce - 3201032-01 3233004-01 1 pce 1 pce - 1 pce 1 pce - 3206001-01 3205007-01 3205004-01 3201032-01 2104264-02 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce - 3224001-01* 2101005-01 100294-01 100312-01 1508001-01 3615001-01 2104007-01* LSCOPE-9 3 pcs 1pce 1 pce 1 pce 12 pcs 1 pce 1 pce 1 pack 1 pce - 3 pcs 1pce 1 pce 1 pce 12 pcs 1 pce 1 pce - 2104375-01 1716016-01 1603004-03 1605059-01 1819001-02 SRP-006-160 1pce 3 pcs 2 pcs 1 pce 2 pcs 1 pce 3 pcs 1 pce 3 pcs 2 pcs 1 pce 1 pce 1 pce 2 pcs 1 pce Note: All materials in the list of contents, except those marked with *, can be ordered separately Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Anaerobic connector tool kits/ February 2009 Ordering information: Type Description Quantity/deliver unit Ordering number Type Description Quantity/deliver unit Ordering number Anaerobic tool kit for (ST/FC/SC/LC) GIC and all-ceramic connectors Consumables for anaerobic tool kits 1/1 1/1 TKT-ANAEROBIC2-EMEA TKT-ANAEROBIC2-C-EMEA Anaerobic tool kit for (ST/FC/SC) GIC and all-ceramic conn. 2.5mm ferrule Integration for TKT-ANAEROBIC2-25 for LC terminations 1/1 1/1 TKT-ANAEROBIC2-25-EMEA TKT-ANAEROBIC2-S Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Buffer tube indoor and outdoor single fibre f an-out kits FAN-xxxx-xx / March 2007 ® Product Family: LANscape Fan-out kits Product: Buffer tube indoor and outdoor single fibres fan-out-kits Fibre: Multimode and Single-Mode Fibres Applications The Corning Cable Systems’buffer-tube fan-out kits are intended for the furcation of buffer tubes onto 900µm legs as required to field-install connectors on bare fibres. Different kits are available for applications on stranded loose tube cables at indoor or outdoor cross-connection points. In combination with the transition kits the indoor buffer tubes fan-out kits can be also installed on single maxi-tube cables. Description Corning Cable Systems’indoor and outdoor buffer tube fan-out kits are specifically designed for the termination of 6- and 12-fibres buffer tubes. These kits provide the ultimate solution for the field termination of loose tube cables by means of a compact easy to install assembly not requiring additional hardware or space than that required for terminating tight buffered cables. Indoor and outdoor kits feature a 900µm fan-out assembly that is colour coded to match the fibres colour scheme (to Telcordia). The fan-out assembly is available with 6- or 12-fibres units in lengths of 600 mm (25-in.) or 1200 mm (47-in). These different lengths provide the flexibility needed for installation in a variety of hardware options. Buffer tube fan-out kit Buffer tube fan-out kit: furcation unit Features / Benefits − − − − − − − − − − − Eliminates strain on fibres by isolating them from tensile forces Colour coded fan-out tubing to Telcordia: 6 fibres: blue, orange, green, brown, grey, white 12 fibres: blue, orange, green, brown, grey, white, red, black, yellow, violet, pink, aqua Snap-together furcation unit eliminates epoxy resin for indoor kits. Compact design. Quick and easy to install. Optimized for field termination of loose tube cables. Excellent fibre routing capabilities. Bend radius protection designed into each unit. Indoor temperature range: 0 °C – +70 °C. Outdoor temperature range: -40 °C – +70 °C Single maxi-tube cables fan-out extension kits suitable for single maxi-tube cables containing individual fibres or up to 5 bundles with up to 12 fibres each. Buffer tube fan-out kit for single maxitube cables Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Data sheet Buffer tube indoor and outdoor single fibre f an-out kits FAN-xxxx-xx / March 2007 Ordering information: Indoor buffer tube fan-out kits 1 2 FAN – BT – Outdoor buffer tube fan-out kits 1 2 FAN – OD – Use the following options to construct the part number: 1 Select length of furcation length (900µm tubing) 25 = 600 mm (25-in.) 47 = 1200 mm (47-in.) 2 Select number of fibres 06 = 6 fibres 12 = 12 fibres Examples: FAN – BT47 – 06 Type designation: Indoor fan-out kit for 6 fibres, length of 900µm tubing = 1200 mm (47-in.). FAN –OD25 – 12 Type designation: Closet fan-out kit for 12 fibres, length of 900µm tubing = 600 mm (25-in.). Optional accessories: Part Number TKT-FANBT-A TKT-FANBT-C EST-END-01-SM EST-END-01-MM Description Buffer tube fan-out assembly tool kit. Includes: buffer tube fan-out assembly fixture, case for buffer tube fan-out assembly fixture. Consumables for buffer tube fan-out assembly tool kit. Includes: buffer tube fan-out clamp, Loctite 411 adhesive (3g), alcohol wipes (20 pcs), Kimwipes (1 pack). Single maxi-tube fan-out kit for single-mode applications: includes funnel, yellow branch tubing, transition heat-shrink sleeves and installation instructions. Single maxi-tube fan-out kit for single-mode applications: includes funnel, orange branch tubing, transition heat-shrink sleeves and installation instructions. Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Datasheet Ribbon fan-out kit RIB-FAN-12-xx / January 2007 Product Family: LANscape® Fan-out kits Product: Single ribbon fan-out-kit Fibre: InfiniCor® SX+ OM3, InfiniCor® 600 OM2, InfiniCor® 300 OM1, SMF-28e™ OS2 Applications The Corning Cable Systems’ ribbon fan-out kit is intended for the furcation of a single ribbone (bare, in a rectangular fan-out tubing or in a ribbon interconnect cable) onto 900µm single fibre legs as required to fieldinstall single fibre connectors. Description The Corning Cable Systems’ ribbon fan-out kit is specifically designed for the indoor termination of 12fibres ribbons bare as well as jacketed (fan-out tubing or ribbon interconnect cable). This kit provide the ultimate solution for the field termination onto single fibre connectors by means of a compact, easy to install assembly not requiring additional hardware or space than that required for terminating tight buffered cables. Single ribbon fan-out kit The ribbon fan-out kit features a 900µm fan-out assembly that is colour coded to match the fibres colour scheme of the ribbon. The fan-out assembly is available with 12-fibres units in lengths of 600 mm (25-in.) or 900 mm (36-in). These different lengths provide the flexibility needed for installation in a variety of hardware options. Features / Benefits − − − − − − − − Eliminates strain on fibres by isolating them from tensile forces Colour coded fan-out tubing for indoor use Snap-together furcation unit eliminates epoxy resin. Compact design. Quick and easy to install. Optimized for field termination of cables. Excellent fibre routing capabilities. Bend radius protection designed into each unit. Ordering information: Ordering number RIB-FAN-12 RIB-FAN-12-36 Note: Ribbon fan-out kit: components Description Ribbon fan-out kit 12x900µm tubing 600mm (25-in.) length Ribbon fan-out kit 12x900µm tubing 900mm (36-in.)length Tubing length mm (in.) 600 (25) 900 (36) 900 mm (36-in.) length is only recommended if installing into connector modules; 600 mm (25-in.) length is recommended for connector panels and other Corning Cable Systems hardware. C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Datasheet Spider fan-out kits SFK-x-xx-xxx-x / January 2007 Product Family: LANscape® Fan-out kits Product: Spider fan-out-kits Fibre: InfiniCor® SX+ OM3, InfiniCor® 600 OM2, InfiniCor® 300 OM1, SMF-28e™ OS2 Applications The Corning Cable Systems’ spider fan-out kits are intended for the furcation of loose tube or tight buffered cables buffer tubes onto ruggedized legs to realize multifibres cable assemblies to be used for direct connections without use of patch panels. Different kits are available for application on loose tube, tight buffered or ribbon cables. Description Corning Cable Systems’ spider fan-out kits are a low cost termination option for multifibre cables. These kits are designed for both factory and field termination of tight-buffered, loose tube (with 4 to 24 fibres) and single tube ribbon (24 to 96 fibres) non-armoured cables. These kits provide a modular, easy installable solution based on a simple step-by-step assembly that grants a successful installation. Installation of spider fan-out kits eliminates the need for patch panels at low-cost termination points. The spider fan-out kits terminate and provide pull-out protection for single fibres (tight buffered 900µm or bare fibres 250µm) or bare 12-fibres ribbons; the single fibres or the ribbons are threaded into the modular inserts which consist of a composite assembly securing, for single fibres, six 1-meter lengths of fan-out tubing, and for 12-fibre ribbons two 1-meter lengths of rectangular fan out tubing. The fan-out tubing (for single fibre as well as for ribbon) provide three layers of protection consisting of a Teflon inner tube (into which the fibre or the ribbon is inserted) an aramid yarn strenght member and an outer protective PVC Jacket. The fan-out insert snaps into the main spider body which is then enclosed within the outer housing. Spider fan-out MM OM1/OM2 on tight buffered cable Spider fan-out kit SM on loose tube cable Features / Benefits − − − − − − Modular, compact design. No special tool or heat-shrink sleeve Field or factory termination Fan-out tubing length of one meter provides flexible installation Cost effective for splicing and terminating hardware Non-metallic/high strength, rugged, composite material. Ribbon spider fan-out kit MM OM3 C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Datasheet Spider fan-out kits SFK-x-xx-xxx-x / January 2007 Specifications : Fibre count 6 to 12 Loose tube/Single tube cable (bare fibre / 250µm) Length Diameter mm (in.) mm (in.) 146 (5.75) 28 (1.1) Mic / A-VQ(BN)H (tight buffered fibre / 900µm) Length Diameter mm (in.) mm (in.) 121 (4.75) 19 (0.75) Single tube ribbon cable (12-fibres ribbon) Length Diameter mm (in.) mm (in.) – – 13 to 24 146 (5.75) 28 (1.1) 146 (5.75) 28 (1.1) – – 24 to 96 – – – – 146 (5.75) 28 (1.1) Acceptable cable outer diameter: Fibre count 6 to 12 Loose tube/Single tube cable (bare fibre / 250µm) Min. O.D. Max. O.D. mm (in.) mm (in.) 8.6 (0.34) 15.7 (0.62) Mic / A-VQ(BN)H (tight buffered fibre / 900µm) Min. O.D. Max. O.D. mm (in.) mm (in.) 4.6 (0.18) 7.1 (0.28) Single tube ribbon cable (12-fibres ribbon) Min. O.D. Max. O.D. mm (in.) mm (in.) – – 13 to 24 8.6 (0.34) 15.7 (0.62) 6.6 (0.26) 10.9 (0.43) – – 24 to 96 – – – – 8.6 (0.34) 15.7 (0.62) Ordering information: H indicates the RoHS compliance 1 SFK – 2 – 3 – 4 – H Use the following options to construct the part number: 1 Select length of furcation length (900µm tubing) P = 3mm (single fibre) or rectangular (ribbon) fanout tubing P2 = 2mm (single fibre) fan-out tubing 2 Select number of fibres 06 = up to 6 single fibres 12 = up to 12 single fibres 18 = up to 18 single fibres 24 = up to 24 single fibres or 2 ribbons (24 fibres) 48 = up to 4 ribbons (48 fibres) 72 = up to 6 ribbons (72 fibres) 96 = up to 8 ribbons (96 fibres) 3 Select fibre type 900 = accepts 900µm tight buffered fibres 250 = accepts 250µm bare fibres RIB = accepts 12 fibres ribbon 4 Select fan-out tubing colour M = Orange (62.5µm or standard 50µm multimode) S = Yellow (single-mode) A = Aqua (laser optimized 50µm multimode) Examples: SFK – P – 06 – 900 – SH Type designation: Spider fan-out kit for 6x 900µm single-mode fibres, 6 fan-out tubings 3mm diameter, yellow. SFK – P2 – 24 – 250 – AH Type designation: Spider fan-out kit for 24x250µm multimode 50µm laser optimized fibres (OM3), 24 fan-out tubings 2mm in diameter, aqua. SFK – P – 24 – RIB –MH Type designation: Spider fan-out kit for 2xribbon (24 fibres) multimode 50µm or 62.5µm fibres (OM3), 2 rectangular fan-out tubings, orange. C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Datasheet Spider fan-out kits SFK-x-xx-xxx-x / January 2007 Optional accessories: Part Number Description 2104148-01 6 fibres insert plug for bare fibres (250µm) orange (62.5µm or standard 50µm multimode). 2104149-01 6 fibres insert plug for tight buffered fibres (900µm) orange (62.5µm or standard 50µm multimode). 2104150-01 6 fibres insert plug for bare fibres (250µm) yellow (single-mode). 2104151-01 6 fibres insert plug for tight buffered fibres (900µm) yellow (single-mode). SFK-P-IH-RIB-A SFK-P-IV -RIB-A SFK-P-IH-RIB-M SFK-P-IV-RIB-M SFK-P-IH-RIB-S SFK-P-IV-RIB-S 2 horizontal ribbons insert plug aqua (multimode 50µm laser optimized fibres) 2 vertical ribbons insert plug aqua (multimode 50µm laser optimized fibres) 2 ribbons horizontal insert plug orange (62.5µm or standard 50µm multimode). 2 ribbons horizontal insert plug orange (62.5µm or standard 50µm multimode). 2 ribbons horizontal insert plug yellow (single mode). 2 ribbons horizontal insert plug yellow (single mode). 2104189-01 Blank plug C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Datasheet CamSplice™ 95-000-04-xxx / January 2007 Product Family: LANscape® CamSplice™ no-adhesive mechanical splice Product: CamSplice™ no-adhesive mechanical splice Fibre: InfiniCor® SX+ OM3, InfiniCor® 600 OM2, InfiniCor® 300 OM1, SMF-28e™ OS2 Applications Corning Cable Systems’ CamSplice™ no-adhesive mechanical splices are especially indicated for emergency restoration and lab splicing for temporary system testing. They offer also a simple solution for those cases where the use of a fusion splice machine is not practicable. Description Corning Cable Systems’ CamSplice™ is a simple, craftfriendly mechanical splice for both multimode and single-mode fibres. It features a “cam” locking mechanism, which requires no adhesive. The CamSplice™ mechanical splice incorporate a unique, patented fibre alignment method that self-centres the fibres and provides extremely accurate alignment. Average “blind” (non-tuned) splice loss for the CamSplice™ mechanical splice is specified at 0.3 dB with a minimum loss less than 0.15 dB. There is only one part for 250 µm to 250 µm, 250 µm to 900 µm or 900 µm to 900 µm applications (one size fits all). The CamSplice™ mechanical splice requires minimal training and few accessories to assemble. The assembly process involves stripping and cleaving fibres, inserting the fibres into the splice part until they touch and turning the cams to secure the fibre. The process does not involve any adhesives or special tools, although an optional assembly fixture is recommended. A typical installation takes less than two minutes. A compact, self-contained tool kit is available with standard tools including the optional the assembly fixture. CamSplice™ and antitorsion CamSplice™ CamSplice™ assembly tool Completed splices fit in Corning Cable Systems and many other industry standard splice trays. Features / Benefits − − − − − − − − − No adhesive or epoxy required Universal: one part fits all fibre coatings Re-mateable, tunable. Self centring alignment mechanism. Antitorsion option with lead-in tubes for securing 900µm tight buffered fibres. Pre-inserted index-matching gel. No stress in fibre alignment area. Small assembly fixture recommended, but optional. Fits in most industry standard splice trays. C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU. Datasheet CamSplice™ 95-000-04-xxx / January 2007 Characteristics Dimensions LxW: mm (in.) Typical splice loss: dB Typical “blind” splice loss: dB Reflectance (flat cleave): dB Reflectance (angled cleave): dB Tensile strength: N Temperature range: Vibration 44.0 x 4.2 (1.73 x 0.17) 0.15 0.3 ≤ -45 dB ≤ -60 dB 2.25 -40 – +75 °C, ∆IL ≤ 0.1 dB average 10 – 55 Hz, amplitude max. 1.52 m, 3 axis, 2 h each, ∆IL ≤ 0.5 dB Ordering information: Description Ordering number 95-000-04 95-000-04-ATC* CamSplice™ mechanical splice Antitorsion CamSplice™ mechanical splice for 900µm applications Quantity/ delivery unit 6/1 900 (36) * Once crimped the antitorsion CamSplice™ is not re-mateable Optional accessories: Part Number Description TKT-100-01 CamSplice™ tool kit, includes CamSplice™ assembly fixture, fibre coating stripping tool. TKT-100-02 CamSplice™ tool kit with cleaver, includes CamSplice™ assembly fixture, fibre coating stripping tool and Score & Snap Cleaver. 2104040-01 2104200-01 CamSplice™ assembly fixture. Crimp tool for antitorsion CamSplice™ mechanical splice FBC-001 FBC-006 Score & Snap cleaver. Precision fibre cleaver. Tool kits contents Item CamSplice™ assembly tool Fibre cleaver, score & snap Stripper 6” wire Jensen tool Stripper, No-nicks, 203µm Fibre stripper, plier type Scissors 5” electrician Marker black Tweezers Black tape, electrical,3/4”x20’ Wipes alcohol Bottle 60 ml dispensing Book of numbers 0 - 9 Instructions CamSplice™ assembly Instructions FBC-001 cleaver Instructions fibre stripping tool Instructions buffer stripping tool Instructions stripper No-nicks, 203µm Item code 2104040-01 FBC-001 3206001-01 3205007-01 3205004-01 100294-01 2104007-01* 100312-01 2104047-01 1508001-01 1604003-01* 100297-01 SRP-006-038 SRP-001-040 SRP-005-006 SRP-005-005 SRP-004-036 TKT-100-01 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 6 pcs 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce TKT-100-02 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 6 pcs 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce 1 pce Note: All items in the content lists, except those marked with *, can be ordered separately C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Modify Date : 2010:09:15 13:15:04+02:00 Create Date : 2010:09:15 13:13:19+02:00 Metadata Date : 2010:09:15 13:15:04+02:00 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : Spec Sheet_A4_V_final_Layout 1 Creator : KuhlemanS Document ID : uuid:aec20fe6-ac62-4175-822b-00d5fc61f3c6 Instance ID : uuid:6e7a090f-a303-44eb-9f24-bd7c0d501167 Producer : Acrobat Distiller 8.1.0 (Windows) Has XFA : No Page Count : 31 Author : KuhlemanSEXIF Metadata provided by EXIF.tools