Spec Sheet_A4_V__

2014-07-04

: Pdf 673038-Attachment 673038-Attachment 009602 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 31

DownloadSpec Sheet_A4_V__
Open PDF In BrowserView PDF
3

Fibre Termination
3.1. UniCam
3.1.1. UniCam Pretium
3.1.2. UniCam Standard
3.1.3. UniCam 250 μm
3.1.4. UniCam SC-APC
3.1.5. UniCam MTP
3.1.6. UniCam Tool Kit
3.2. Anaerobic
3.2.1. Anaerobic Connectors
3.2.2. Anaerobic Tool Kit
3.3. Furcation Kit
3.3.1. Buffer Tube Fan Out
3.3.2. Ribbon
3.3.3. Spider Fan Out
3.4. Camsplice

Data sheet
Unicam Pretium SC, ST and LC / November 2008

®

Product Family:

LANscape Field Installable Connectors

Product:

UniCam Pretium ST, SC and LC Connectors

Fibre:

InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF-28e+™ OS2

®

®

®

®

Description
The UniCam® Pretium Connector is the ideal solution
for all your field-installable fibre optic connector requirements. The quick installation reduces the total
installed cost of connectorization, making the UniCam
Connector cost-effective for all fibre applications,
from the main cross-connect to the workstation. The
UniCam Connector can best be described as a mini
pigtail. It incorporates a factory-installed fibre stub
that is fully bonded in the ferrule. The other end is
precisely cleaved and placed into the patented
alignment mechanism of a mechanical splice. Both
the field fibre and fibre stub are fully protected from
environmental factors. Unlike other no epoxy, fieldinstallable connectors, the UniCam Connector
requires no polishing.
The unique features of the Unicam are the accuracy
of the factory polished end face process, 100%
quality control of every connector and the visual
feedback system during field installation.
Applications
All field-installable UniCam® Pretium connector
versions provide a high-quality alternative to epoxy
and polish connectors. They provide simple, quick
and reliable connector installation on site. Fibre stubs
are pre-installed in the ferrules of the UniCam
connectors at the factory, thus eliminating the critical
epoxy and polish operations in the field. This
approach also allows the necessary high quality,
controlled end face processing to be performed as
part of the production process in the factory, thus
reducing field technician influence to a minimum. On
site, the stripped and cleaved field fibres are inserted
into the UniCam connectors and retained. A
mechanical splice inside the connector establishes
the low-loss connection between the field fibre and
the preinstalled fibre inside the connector.
Features / Benefits
- Fastest termination time in the industry: less than
1 min with single fibre connector
- Continuity- Test-Set gives immediate go/no go
feedback of successful termination

3-D view from polished end face of a Unicam connector

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Unicam Pretium SC, ST and LC / November 2008

Characteristics
Connector type
Ferrule
Connector body
Insertion loss, typical (dB) MM
Insertion loss, max. (dB) MM
Reflectance Multimode typical
(dB) MM PC OM1/OM2
Reflectance Multi Mode typical
(dB) MM PC OM3
Insertion loss, typical (dB) SM
Insertion loss, max. (dB) SM
Reflectance Single-Mode
typical (dB) MM UPC
Cycling to FOTP-21

ST/PC
Ceramic
Composite
0.10
0.50

SC/PC
Ceramic
Composite
0.10
0.50

LC/PC
Ceramic
Composite
0.10
0.50

-20

-20

-20

-26

-26

-26

0.20
0.50

0.20
0.50

0.20
0.50

-55**

-55**

-55**

0.2 dB, 500 cycles

Max. Tensil load Connector

44N on 2.0mm and 2.8mm Legs / Cable

Max. Tensil load Connector
4N on 900µm Legs / Tight Buffer
Temperatur in operation
-40°C to 75°C
Temperature cycling to FOTP-3
IL 0.3 dB, -40 – +75 °C, 21 cycles
* The insertion loss values is only for using Unicam Pretium Tool Kit. When using the standard Tool Kit the values are
0,3dB typical and 0.75 maximum.
** Please Note: The reflectance values are for 18° to 26° C

Connectors according to standard
SC
ST compatible
LC

TIA/EIA 604-3 / IEC 61754-4
TIA/EIA 604-2 / IEC 61754-2
TIA/EIA 604-10A / IEC 61754-20

Connector Identification according to EIA/TIA-568-C.3 Draft 2006
Colour code:
OM3 (50 m)
OM2 (50 m)
OM1 (G62,5µm)
OS1/OS2 (E9) UPC

Housing
Black
Black
Beige
Blue

Boot
Aqua
Black
Black
Blue

Contents Single pack
Connector type
SC
ST compatible
LC

Connector
X
X
X

Crimp ring
X
X
X

Boot 900µm
X
X
X

Boot 2.0mm

X

Boot 2.8mm
X
X
X

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Unicam Pretium SC, ST and LC / November 2008

Optical Characteristics of fibres:
®
Laser optimised multi-mode fibre 50/125 µm, InfiniCor SX+ OM3
Laser bandwidth at 850 nm: 2000 MHz·km
Fibre core diameter: 50.0 + 2.5 µm
Fibre meets or exceeds standards: TIA/EIA 492AAAC-A, IEC 60793-2-10 Type A1a.2, ISO/IEC 11801 OM3.
Fibre tested using minEMBc method, according to TIA/EIA 455-220, IEC 60793-2-10 Ed 2.0 and
IEC 60793-1-49 Ed 2.0.
®

Laser optimised multi-mode fibre 50/125 µm, InfiniCor 600 OM2
Laser bandwidth at 850 nm: 585 MHz·km
Fibre core diameter: 50.0 + 2.5 µm
Fibre meets or exceeds standards: TIA/EIA 492AAAB; IEC 60793-2-10 Type A1a.1; ISO/IEC 11801 OM2.
Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41.
Laser optimised multi-mode fibre 62.5/125 µm, InfiniCor® 300 OM1
Laser bandwidth at 850 nm: 220 MHz·km
Fibre core diameter: 62.5 + 2.5 µm
Fibre meets or exceeds standards: TIA/EIA 492AAAA; IEC 60793-2-10 Type A1b.1; ISO/IEC 11801 OM1.
Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41.
Laser optimised single-mode fibre 9/125 µm, SMF 28e+™ OS2
Mode-Field diameter at 1310: 9.2 + 0.4 µm
Mode-Field diameter at 1550: 10.4 + 0.5 µm
Fibre meets or exceeds standards: TIA/EIA 492-CAAB, IEC 60793-2-50 Type B1.3, ISO/IEC 11801 OS2,
Telcordia GR20.
Order information
SC
Ordering number
95-000-41
95-050-41
95-050-41-X
95-200-42

Description SC Connectors
Unicam SC-Connector with Ceramic ferrule, Multimode 62,5µm
Unicam SC-Connector with Ceramic ferrule, Multimode 50µm
Unicam SC-Connector with Ceramic ferrule, Multimode 50µm
Unicam SC/UPC-Connector with Ceramic ferrule, Single-mode 9µm

Fibre type
OM1
OM2
OM3
OS1/OS2

Description ST Connectors
Unicam ST-Connector with Ceramic ferrule, Multimode 62,5µm
Unicam ST-Connector with Ceramic ferrule, Multimode 50µm
Unicam ST-Connector with Ceramic ferrule, Multimode 50µm
Unicam ST/UPC-Connector with Ceramic ferrule, Single-mode 9µm

Fibre type
OM1
OM2
OM3
OS1/OS2

Description LC Connectors
Unicam LC-Connector with Ceramic ferrule, Multimode 62,5µm
Unicam LC-Connector with Ceramic ferrule, Multimode 50µm
Unicam LC-Connector with Ceramic ferrule, Multimode 50µm
Unicam LC-Connector with Ceramic ferrule, Single-mode 9µm

Fibre type
OM1
OM2
OM3
OS1/OS2

ST
Ordering number
95-000-51
95-050-51
95-050-51-X
95-200-52
LC
Ordering number
95-000-99
95-050-99
95-050-99-X
95-200-99

Minimum Order Quantity in multiples of 25 pce

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Unicam Classic SC, ST, FC & MT-RJ/ November 2008

®

Product Family:

LANscape Field Installable Connectors

Product:

UniCam Classic ST, SC, FC & MT-RJ Connectors

Fibre:

InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF-28e+™ OS2

®

®

®

®

Description
The UniCam® Standard Connectors are the ideal
solution for all your field-installable fibre optic
connector requirements. The quick installation
reduces the total installed cost of connectorization,
making the UniCam Connector cost-effective for all
fibre applications, from the main cross-connect to the
workstation. The UniCam Connector can best be
described as a mini pigtail. It incorporates a factoryinstalled fibre stub that is fully bonded in the ferrule.
The other end is precisely cleaved and placed into the
patented alignment mechanism of a mechanical
splice. Both the field fibre and fibre stub are fully
protected from environmental factors. Unlike other no
epoxy, field-installable connectors, the UniCam
Connector requires no polishing.
The unique features of the Unicam are the accuracy
of the factory polished end face process, 100%
quality control of every connector and the visual
feedback system during field installation.
Applications
The field-installable UniCam® connector versions
provide a high-quality alternative to epoxy and polish
connectors. They provide simple, quick and reliable
connector installation on site. Fibre stubs are preinstalled in the ferrules of the UniCam connectors at
the factory, thus eliminating the critical epoxy and
polish operations in the field. This approach also
allows the necessary high quality, controlled end face
processing to be performed as part of the production
process in the factory, thus reducing field technician
influence to a minimum. On site, the stripped and
cleaved field fibres are inserted into the UniCam
connectors and retained. A mechanical splice inside
the connector establishes the low-loss connection
between the field fibre and the preinstalled fibre
inside the connector.
Features / Benefits
- Fastest termination time in the industry: less than
1 min with single fibre connector
- Fastest termination time in the industry: less than
3 min with MTRJ connector
- Continuity- Test-Set gives immediate go/no go
feedback of successful termination
- Minimal tool kit, reduced setup time; universal
assembly tool terminates all single- and 2-fiber
UniCam Connector styles

3-D view from polished endface of a Unicam connector

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Unicam Classic SC, ST, FC & MT-RJ/ November 2008

Characteristics
Connector type
Connector body
Ferrule multimode
Insertion loss, typical (dB) MM
Insertion loss, max. (dB) MM
Reflectance Multimode typical
(dB) MM PC OM1/OM2
Reflectance Multi Mode typical
(dB) MM PC OM3
Ferrule singlemode
Insertion loss, typical (dB) SM
Insertion loss, max. (dB) SM
Reflectance Single-Mode typical
(dB) MM UPC
Reflectance Single-Mode typical
(dB) MM SPC
Cycling to FOTP-21

ST/PC
Composite
Composite
0.30
0.75

SC/PC
Composite
Composite
0.30
0.75

FC/PC
Composite
Ceramic
0.30
0.75

MTRJ
Composite
Composite
0.30
0.75

-20

-20

-20

-20

-

-

-

-20

Ceramic
0.20*
0.50*

Ceramic
0.20*
0.50*

Ceramic
0.30
0.75

-

-

-40**

-40**

Composite
-

-55**

-

-40**

-

0.2 dB, 500 cycles

Max. Tensil load Connector

44N on 2.0mm and 2.8mm Legs / Cable

Max. Tensil load Connector
4N on 900µm Legs / Tight Buffer
Temperatur in operation
0°C to 60°C
Temperature cycling to FOTP-3
IL 0.3 dB, -40 – +75 °C, 21 cycles
* The insertion loss values is only for using Unicam Pretium Tool Kit. When using the standard Tool Kit the values are
0,3dB typical and 0.75 maximum.
** Please Note: The reflectance values are for 18° to 26° C
Connectors according to standard
TAI/EIA 604-3 / IEC 61754-4
TAI/EIA 604-2 / IEC 61754-2
TAI/EIA 604-4 / IEC 61754-13
TAI/EIA 604-12 / IEC 61754-18

SC
ST compatible
FC
MT-RJ

Connector Identification according to EIA/TIA-568-C.3 Draft 2006
Colour code:
OM3 (50 m)
OM2 (50 m)
OS2 (E9)
OS1/OS2 (E9) SPC

Housing
Black
Black
Blue
Blue

Boot
Aqua
Black
Blue
White

Contents Single pack
Connector type
SC
ST compatible
FC
MT-RJ

Connector
X
X
X
X

Crimp ring
X
X
X
X

Boot 900µm
X
X
X

Boot 2.0mm

Boot 2.8mm
X
X
X
X

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Unicam Classic SC, ST, FC & MT-RJ/ November 2008

Optical Characteristics of fibres:
Laser optimised multi-mode fibre 50/125 µm, InfiniCor® SX+ OM3
Laser bandwidth at 850 nm: 2000 MHz·km
Fibre core diameter: 50.0 + 2.5 µm
Fibre meets or exceeds standards: TIA/EIA 492AAAC-A, IEC 60793-2-10 Type A1a.2, ISO/IEC 11801 OM3.
Fibre tested using minEMBc method, according to TIA/EIA 455-220, IEC 60793-2-10 Ed 2.0 and
IEC 60793-1-49 Ed 2.0.
®

Laser optimised multi-mode fibre 50/125 µm, InfiniCor 600 OM2
Laser bandwidth at 850 nm: 585 MHz·km
Fibre core diameter: 50.0 + 2.5 µm
Fibre meets or exceeds standards: TIA/EIA 492AAAB; IEC 60793-2-10 Type A1a.1; ISO/IEC 11801 OM2.
Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41.
®

Laser optimised multi-mode fibre 62.5/125 µm, InfiniCor 300 OM1
Laser bandwidth at 850 nm: 220 MHz·km
Fibre core diameter: 62.5 + 2.5 µm
Fibre meets or exceeds standards: TIA/EIA 492AAAA; IEC 60793-2-10 Type A1b.1; ISO/IEC 11801 OM1.
Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41.

Laser optimised single-mode fibre 9/125 µm, SMF 28e+™ OS2
Mode-Field diameter at 1310: 9.2 + 0.4 µm
Mode-Field diameter at 1550: 10.4 + 0.5 µm
Fibre meets or exceeds standards: TIA/EIA 492-CAAB, IEC 60793-2-50 Type B1.3, ISO/IEC 11801 OS2,
Telcordia GR20.

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Unicam Classic SC, ST, FC & MT-RJ/ November 2008

Order Information
SC
Ordering number
95-000-40
95-050-40
95-200-41

Description SC Connectors
Unicam SC-Connector with composite ferrule, Multimode 62,5µm
Unicam SC-Connector with composite ferrule, Multimode 50µm
Unicam SC/SPC-Connector with Ceramic ferrule, Single-mode 9µm

Fibre type
OM1
OM2
OS1/OS2

Description ST Connectors
Unicam ST-Connector with composite ferrule, Multimode 62,5µm
Unicam ST-Connector with composite ferrule, Multimode 50µm
Unicam ST/SPC-Connector with Ceramic ferrule, Single-mode 9µm

Fibre type
OM1
OM2
OS1/OS2

ST
Ordering number
95-000-50
95-050-50
95-200-51
FC
Description FC Connectors
Ordering number
95-000-61
Unicam FC-Connector with Ceramic ferrule, Multimode 62,5µm
95-200-61
Unicam FC-Connector with Ceramic ferrule, Single-mode 9µm
95-200-62
Unicam FC-Connector with Ceramic ferrule, Single-mode 9µm
*Please Note: This Connector may not be used with Unicam Pretium Tool Kit

Fibre type
OM1
OS1/OS2
OS1/OS2

MT-RJ with Pins
Ordering number
Description MT-RJ Connectors with pins
92-001-97-P-E
Unicam MT-RJ Connector with pins Composite ferrule, Multimode 62,5µm
92-051-97-P-E
Unicam MT-RJ Connector with pins Composite ferrule, Multimode 50µm
92-051-97-P-E-X
Unicam MT-RJ Connector with pins Composite ferrule, Multimode 50µm
*Please Note: This Connector may not be used with Unicam Pretium Tool Kit

Fibre type
OM1
OM2
OM3

MT-RJ without Pins
Ordering number
Description MT-RJ Connectors without pins
Unicam MT-RJ Connector without pins Composite ferrule, Multimode 62,5µm
92-001-97-NP-E
Unicam MT-RJ Connector without pins Composite ferrule, Multimode 50µm
92-051-97-NP-E
Unicam MT-RJ Connector without pins Composite ferrule, Multimode 50µm
92-051-97-NP-E-X
*Please Note: This Connector may not be used with Unicam Pretium Tool Kit

Fibre type
OM1
OM2
OM3

Minimum Order Quantity in multiples of 25 pce

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Unicam 250µm Pretium SC, LC / November 2008

Product Family:

®

LANscape Field Installable Connectors
®

TM

Product:

UniCam 250µm Pretium

Fibre:

InfiniCor OM3, InfiniCor OM2, InfiniCor OM1, SMF-28+™ OS2

®

SC and LC connectors

®

Description
The UniCam® 250µm connector is the ideal solution
for field-installable fibre optic connector requirements
on 250µm bare fibres. The quick installation reduces
the total installed cost of connectorization, making the
UniCam connector cost-effective for all fibre
applications, from the main cross-connect to the
workstation. The UniCam connector can best be
described as a mini pigtail. It incorporates a factoryinstalled fibre stub that is fully bonded in the ferrule.
The other end is precisely cleaved and placed into the
patented alignment mechanism of a mechanical
splice. Both the field fibre and fibre stub are fully
protected from environmental factors. Unlike other
no-epoxy, field-installable connectors requires the
UniCam connector no polishing.

®

Pre-assembled fibre
Field insert fibre

The unique features of the Unicam are the accuracy
of the factory polished end face process, 100%
quality control of every connector and the visual
go/no go feedback system during field installation.
Applications
The field-installable UniCam® 250µm connector
versions provide a high-quality, quick and reliable
connector installation on site. The direct termination
on loose- or central tube cables with standard 250µm
fibres do not require additional accessories. The high
quality end face, controlled during the production
process in the factory, reduces field technician
influence to a minimum. On site, the stripped and
cleaved field fibres are inserted into the UniCam
connectors and retained. A mechanical splice inside
the connector establishes the low-loss connection
between the field fibre and the preinstalled fibre
inside the connector.

Cam splice
Factory-made high-performance polishing

Features / Benefits
- Fastest termination time in the industry:
Less than 1 min with single fibre possible
- Pretium Tool Kit gives immediate go/no go
feedback of successful termination
- Minimal Unicam Pretium Tool Kit allows reduced
setup time; universal assembly tool terminates all
LC and SC UniCam Connector directly on 250µm
bare fibres
- Dimensions for fibre preparation are printed on the
connector kit package

3-D view from polished endface of a Unicam connector

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Unicam 250µm Pretium SC, LC / November 2008

Characteristics
Connector type
Ferrule
Connector body
Insertion loss*, typical (dB) MM
Insertion loss*, maximum (dB) MM
Reflectance**Multimode typical (dB)
MM/PC OM1/OM2
Reflectance** Multi Mode typical (dB)
MM/PC OM3
Insertion loss*, typical (dB) SM*
Insertion loss*, maximum (dB) SM*
Reflectance**Single-Mode typical
(dB) SM/UPC OS2
Cycling to FOTP-21

SC
Ceramic
Composite
0.1*
0.5*

LC
Ceramic
Composite
0.1*
0.5*

-20

-20

-26

-26

0.2
0.5

0.2
0.5

-55**

-55**
0.2 dB, 500 cycles

Max. Tensil load Connector
2N on 250µm Bare fibre with 0.2 change
Temperatur in operation
-40°C to 75°C
Temperature cycling to FOTP-3
IL 0.3 dB, -40 – +75 °C, 21 cycles
* The insertion loss values is only for using Unicam Pretium Tool Kit. When using the standard Tool Kit the values are
0,3dB typical and 0.75 maximum.
** Please Note: The reflectance values are for 18° to 26° C

Connectors according to standard
SC
LC

TAI/EIA 604-3 / IEC 61754-4
TAI/EIA 604-10A / IEC 61754-20

Connector Identification according to EIA/TIA-568-C.3 Draft 2006
Colour code:
OM3 (50 m)
OM2 (50 m)
OM1 (62.5 m)
OS2 (E9) UPC

Housing
Black
Black
Beige
Blue

Boot
Aqua
Black
Beige
Blue

Contents Single pack
Connector type
SC
LC

Connector / Housing /
Dust cab
X
X

Tube

Boot 900µm

X
X

X
X

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Unicam 250µm Pretium SC, LC / November 2008

Optical Characteristics of fibres:
Laser optimised multi-mode fibre 50/125 µm, InfiniCor® OM3
Laser bandwidth at 850 nm: 2000 MHz·km
Fibre core diameter: 50.0 + 2.5 µm
Fibre meets or exceeds standards: TIA/EIA 492AAAC-A, IEC 60793-2-10 Type A1a.2, ISO/IEC 11801 OM3.
Fibre tested using minEMBc method, according to TIA/EIA 455-220, IEC 60793-2-10 Ed 2.0 and
IEC 60793-1-49 Ed 2.0.
®

Laser optimised multi-mode fibre 50/125 µm, InfiniCor OM2
Laser bandwidth at 850 nm: 585 MHz·km
Fibre core diameter: 50.0 + 2.5 µm
Fibre meets or exceeds standards: TIA/EIA 492AAAB; IEC 60793-2-10 Type A1a.1; ISO/IEC 11801 OM2.
Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41.
®

Laser optimised multi-mode fibre 62.5/125 µm, InfiniCor OM1
Laser bandwidth at 850 nm: 220 MHz·km
Fibre core diameter: 62.5 + 2.5 µm
Fibre meets or exceeds standards: TIA/EIA 492AAAA; IEC 60793-2-10 Type A1b.1; ISO/IEC 11801 OM1.
Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41.

Laser optimised single-mode fibre 9/125 µm, SMF 28e+™ OS2
Mode-Field diameter at 1310: 9.2 + 0.4 µm
Mode-Field diameter at 1550: 10.4 + 0.5 µm
Fibre meets or exceeds standards: TIA/EIA 492-CAAB, IEC 60793-2-50 Type B1.3, ISO/IEC 11801 OS2,
Telcordia GR20.

Order information
TM

SC Pretium

Ordering number
95-000-41P
95-050-41P
95-050-41P-X
95-200-42P

Description SC Connectors
Unicam SC-Connector with Ceramic ferrule, Multimode 62,5µm
Unicam SC-Connector with Ceramic ferrule, Multimode 50µm
Unicam SC-Connector with Ceramic ferrule, Multimode 50µm
Unicam SC/UPC-Connector with Ceramic ferrule, Single-mode 9µm

Fibre type
OM1
OM2
OM3
OS2

Description LC Connectors
Unicam LC-Connector with Ceramic ferrule, Multimode 62,5µm
Unicam LC-Connector with Ceramic ferrule, Multimode 50µm
Unicam LC-Connector with Ceramic ferrule, Multimode 50µm
Unicam LC/UPC-Connector with Ceramic ferrule, Single-mode 9µm

Fibre type
OM1
OM2
OM3
OS2

LC PretiumTM
Ordering number
95-000-99P
95-050-99P
95-050-99P-X
95-200-99P

Minimum Order Quantity in multiples of 25 pce

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
UniCam Pretium SC/APC / October 2008

®

Product Family:

LANscape Field Installable Connectors

Product:

UniCam Pretium SC - APC connectors (Pretium Tool Compliant)

Fibre:

SMF-28+™ OS2

®

Description
The field-installable UniCam® APC connector is the
ideal solution to minimize back reflectance from laser
sources, a critical requirement for applications such
as analogue video. UniCam APC Connectors, with
their 8º angled end-face and factory polish,
dramatically reduce reflectance. The quick installation
reduces the total installed cost of connectorization,
making the UniCam connector cost-effective for all
fibre applications, from the main cross-connect to the
workstation. The UniCam connector can best be
described as a mini pigtail. It incorporates a factoryinstalled fibre stub that is fully bonded in the ferrule.
The other end is precisely cleaved and placed into the
patented alignment mechanism of a mechanical
splice. Both the field fibre and fibre stub are fully
protected from environmental factors. Unlike other
no-epoxy, field-installable connectors requires the
UniCam connector no polishing.

Pre-assembled fibre
Field insert fibre

The unique features of the UniCam are the accuracy
of the factory polished end face process, 100%
quality control of every connector and the visual
go/no go feedback system during field installation.
Applications
The field-installable UniCam® APC connector
versions provide a high-quality, quick and reliable
connector installation on site. The direct termination
on tight buffer, loose- or central tube cables do not
require any additional accessories. The high quality
end face, controlled during the production process in
the factory, reduces field technician influence to a
minimum. On site, the stripped and cleaved field
fibres are inserted into the UniCam connectors and
retained. A mechanical splice inside the connector
establishes the low-loss connection between the field
fibre and the preinstalled fibre inside the connector.

Cam splice
Factory-made high-performance polishing

Features / Benefits
- Fastest termination time in the industry:
Less than 1 min with single fibre possible
- Pretium Tool Kit gives immediate go/no go
feedback of successful termination
- Minimal UniCam Pretium Tool Kit allows reduced
setup time; universal assembly tool terminates all
SC UniCam Connector directly on 250µm bare
fibres or tight buffer
- Dimensions for fibre preparation are printed on the
connector kit package
Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
UniCam Pretium SC/APC / October 2008

Characteristics
Connector type
Ferrule
Connector body
Insertion loss, typical (dB) at 18 - 26°
Insertion loss, maximum (dB) at 0° - 60°
Reflectance typical (dB) at 18 - 26°
Reflectance maximum (dB) at 0° - 60°
Cycling to FOTP-21
Max. Tensile load Connector
Temperature in operation

SC/APC
Ceramic
Composite
0.40
0.75
-60
-40
0.2 dB, 500 cycles

0.2 change

2N on 250µm Bare fibre, 4N on 900um, 44N on cable
0°C to 60°C , meets TIA/EIA 568-B.3

*Please Note: This values are only valid when utilizing the FBC-015 cleaver (blue). Cleaving values: 1° +/- 1°

Connectors according to standard
SC

TAI/EIA 604-3 / IEC 61754-4

Connector Identification according to EIA/TIA-568-C.3 Draft 2006
Colour code:
OS2 (E9) APC

Housing
Green

Boot
Green

Contents Single pack
Connector type

SC/APC
SC/APC 250

Connector /
Housing /
Dust cab
X
X

Tube

Boot 900µm

X

X
X

Boot 2.0mm

Boot 2.9mm

X

Optical Characteristics of fibres:
Laser optimised single-mode fibre 9/125 µm, SMF 28+™ OS2
Mode-Field diameter at 1310: 9.2 + 0.4 µm
Mode-Field diameter at 1550: 10.4 + 0.5 µm
Fibre meets or exceeds standards: TIA/EIA 492-CAAB, IEC 60793-2-50 Type B1.3, ISO/IEC 11801 OS2,
Telcordia GR20.
Order information
TM

SC Pretium

Ordering number
95-200-44
95-200-44-Z
95-200-44P
95-200-44P-Z

Description SC Connectors
UniCam SC/APC-Connector with Ceramic ferrule, single pack
UniCam SC/APC-Connector with Ceramic ferrule, organizer pack
UniCam SC/APC-250µm Connector with Ceramic ferrule, single pack
UniCam SC/APC-250µm Connector with Ceramic ferrule, organizer pack

Fibre type
OS2
OS2
OS2
OS2

Minimum Order Quantity in multiples of 25 pce

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2008 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Unicam MTP/ November 2008

®

Product Family:

LANscape Field Installable Connectors

Product:

UniCam MTP connectors

Fibre:

InfiniCor OM3, InfiniCor OM2, InfiniCor OM1, SMF-28+e™ OS2

®

®

®

®

Description
The Corning Cable Systems UniCam® MTP®
Connector is the latest innovation in the proven
UniCam Connector family. It is the first no epoxy /
no-polish, field-installable 12-fibre connector in the
industry. It is the ideal solution for applications using
12-fibre ribbons. The UniCam MTP Connector
utilizes the same reliable, proven no-epoxy/no
polish technology as all other Corning Cable
Systems UniCam Connectors. The UniCam MTP
Connector installs with the same push-pull reliability
as the familiar SC connector.

Application
The field-installable UniCam MTP connector
versions provide simple, quick and reliable
connector installation on site. Fibre stubs are preinstalled in the ferrules of the UniCam connectors at
the factory, thus eliminating the critical epoxy and
polish operations in the field. On site, the stripped
and cleaved field fibres are inserted into the
UniCam MTP connectors and retained. A
mechanical splice inside the connector establishes
the low-loss connection between the field fibre and
the preinstalled fibre inside the connector. The
UniCam MTP connector is installable on bare ribbon
or ribbon interconnect cables.

Features / Benefits
- Repair of Plug & Play™ Systems trunk cables
- Terminates jacketed or bare 12-fiber ribbons in
less than five minutes
- Alignment achieved with precision guide pins
- IEEE-802.3, Fibre Channel and
ANSI/TIA/EIA-568 B.3 compliant

C o r n i n g C a b l e S y s t e m s G m b H & C o . K G · L e i p z i g e r S t r a s s e 1 2 1 · 1 0 11 7 B e r l i n , G e r m a n y
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2008Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Unicam MTP/ November 2008

Characteristics
Parameter:
Multimode & Single-Mode
Standard
TAI/EIA 604-5
Insertion loss, typical (dB
≤ 0.5 dB typ.
≤ 1.0 dB max.
Reflectance Multi Mode typical
≤ -20dB for Ultra PC
(dB) MM PC OM3
Reflectance Single-Mode typical
≤ -55dB for Ultra APC
(dB) MM PC OS2
Cycling to FOTP-21
≤ 0.2 dB, 200 cycles
Max. Tensil load Connector
≤10N Ribbon Inter connect
Temperature cycling to FOTP-3
IL 0.3 dB, -40 – +75 °C, 21 cycles
* Please Note: The reflectance values are for 18° to 28°
Optical Characteristics of fibres:
®
Laser optimised multimode fibre 50/125 µm, InfiniCor OM3
Laser bandwidth at 850 nm: 2000 MHz·km
Fibre core diameter: 50.0 + 2.5 µm
Fibre meets or exceeds standards: TIA/EIA 492AAAC-A, IEC 60793-2-10 Type A1a.2, ISO/IEC 11801 OM3.
Fibre tested using minEMBc method, according to TIA/EIA 455-220, IEC 60793-2-10 Ed 2.0 and
IEC 60793-1-49 Ed 2.0.
®

Laser optimised multimode fibre 50/125 µm, InfiniCor OM2
Laser bandwidth at 850 nm: 585 MHz·km
Fibre core diameter: 50.0 + 2.5 µm
Fibre meets or exceeds standards: TIA/EIA 492AAAB; IEC 60793-2-10 Type A1a.1; ISO/IEC 11801 OM2.
Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41.
®

Laser optimised multimode fibre 62.5/125 µm, InfiniCor OM1
Laser bandwidth at 850 nm: 220 MHz·km
Fibre core diameter: 62.5 + 2.5 µm
Fibre meets or exceeds standards: TIA/EIA 492AAAA; IEC 60793-2-10 Type A1b.1; ISO/IEC 11801 OM1.
Fibre tested using RML method, according to TIA/EIA 455-204 and IEC 60793-1-41.
Laser optimised single-mode fibre 9/125 µm, SMF 28e+™ OS2
Mode-Field diameter at 1310: 9.2 + 0.4 µm
Mode-Field diameter at 1550: 10.4 + 0.5 µm
Fibre meets or exceeds standards: TIA/EIA 492-CAAB, IEC 60793-2-50 Type B1.3, ISO/IEC 11801 OS2,
Telcordia GR20.
Order information
Ordering number

Fibre type

Ferrule

93-001-69

62.5µ/OM1

93-051-69

50µ/OM2

93-051-69-X

50µ/OM3

93-201-69

9µ/OS2

93-001-70

62.5µ/OM1

Composite with pins

93-051-70

50µ/OM2

93-051-70-X
93-201-70

Housing

Colour housing

Colour boot

Composite without pins Composite

Beige

Beige

Composite without pins Composite

Black

Black

Composite without pins Composite

Black

Aqua

Composite without pins Composite

Black/Green

Green

Composite

Beige

Beige

Composite with pins

Composite

Black

Black

50µ/OM3

Composite with pins

Composite

Black

Aqua

9µ/OS2

Composite with pins

Composite

Black/Green

Green

Quantity per delivery unit: 1/1

C o r n i n g C a b l e S y s t e m s G m b H & C o . K G · L e i p z i g e r S t r a s s e 1 2 1 · 1 0 11 7 B e r l i n , G e r m a n y
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2008Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
®
UniCam Single and Two Fibre Connector Tool Kits/ May 2009

®

Product Family:

LANscape Field Installable Connectors Tool-Kits

Product:

UniCam Single Fibre Connectors Tool-Kits

Fibre:

OM3 Pretium™ 300, OM2 Pretium™ 150, InfiniCor 300 OM1, SMF-28e™ OS1/OS2

®

®

Applications
®
The Corning Cable Systems’ UniCam tool-kits are
intended for the installation of all Corning Cable
®
Systems’UniCam connectors.
Tool kits with different equipment are available also for
installation of a special group of connectors.
Description
Corning Cable Systems’tool kits for field installable
connectors provide with a collection of essential tools
required for tasks associated with the termination of
fibre optic cable. The tools are thoughtfully assembled
and are stored in compact and easy to carry cases that
are lined with a foam-padding material in order to
protect the high-quality tools.

®

UniCam Pretium Tool Kit

The TKT-UNICAM-PFC includes a lightweight,
handheld installation tool with an immediate go/no-go
feedback signal, providing unmistakable confirmation
of a successful termination. The kit’
s high-performance
cleaver has an integrated fibre scrap bin and a dualclamp precision hold for the field fibre, with a diamond
blade to achieve a superior cleave. The UniCam
Pretium Tool Kit can be used with multimode or
singlemode LC, SC and ST® Compatible UniCam
Connectors (standard and Pretium-performance), and
is
required
to
achieve
Pretium-Performance
specifications for UniCam Pretium-Performance
singlemode Connectors.
®

The classic UniCam Connector Installation Tool Kit
(TKT-UNICAM) is a basic installation tool kit and can
be used to terminate all single- UniCam Connector
styles (SC, LC and ST compatible). UniCam Multimode
Connectors (SC, LC and ST compatible) can achieve
high-performance with the use of this tool.
The UniCam Connector Installation Tool Kit with
Continuity Test Set (TKT-UNICAM-CTS) provides a
visual feedback feature when terminating UniCam SC,
LC or ST Compatible Connectors. Useful for reducing
scrap rates or for training new installers, the TKTUNICAM-CTS-SF is very popular, since the installer
can watch for the red glow in the back of the connector
to dim or disappear. This indicates that the field fibre is
inserted properly in the connector.

UniCam CTS-SF Tool Kit

UniCam® Basic Tool Kit

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2009 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
®
UniCam Single and Two Fibre Connector Tool Kits/ May 2009

Features / Benefits UniCam® Pretium™ Tool Kit
(TKT-UNICAM-PFC)
−
−
−
−
−
−
−

Virtually eliminates human variability in installation,
ensuring consistent, reliable results
UniCam Pretium Installation Tool uses a go/no go
LED to provide unmistakable confirmation of a
successful termination
Pretium Cleaver uses dual-clamp precision and a
diamond blade for a superior cleave
About 60 seconds per connector to install
Sleek, well-organized carrying case with built-in
conveniences
for
easy,
on-the-go
field
terminations.
Tool kit designed to allow work out of the bag,
eliminating set-up and tear-down time
One kit terminates both singlemode and multimode
LC, SC and ST® Compatible Connectors

UniCam Pretium Handheld Tool Kit

Standard UniCam SF Connector Installation Tool
Kit with Continuity Test Set (TKT-UNICAM-CTS-SF)
−
−
−
−

Convenient carrying bag contains all of the
components necessary to terminate UniCam
Connectors
Installs SC, LC and ST compatible connectors in
less than two minutes
One kit terminates singlemode and multimode
UniCam
Connectors CTS option reduces scrap rate and
helps train new installers

Pretium Cleaver

Standard UniCam Connector Installation Tool Kit
(TKT-UNICAM)
−
−
−

Convenient carrying bag contains all of the
components necessary to terminate UniCam
Connectors
Installs SC, LC and ST compatible connectors in
less than two minutes
One kit terminates singlemode and multimode
UniCam

Elite Installation

Cleaver
1-2 Fibers
FBC-001

Standard Score and Snap Cleaver
Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2009 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
®
UniCam Single and Two Fibre Connector Tool Kits/ May 2009

Tool kits contents
Item

Pretium UniCam ® installation tool
with integrated CTS
UniCam Standard Installation Tool
UniCam® CTS-SF complete
VFL
SC and ST® Compatible 2.5 mm
LC Compatible 1.25 mm
Pretium Flat Cleaver with Diamond
Blade and Built-In Fibre Scrap
Container
Fibre cleaver, score & snap
®
Crimp tool, UniCam aramide
Stripper 6”wire Jensen tool
“Dual-Hole”Miller Tool Fibre
Stripper (for 900 m and 250 m
fibre)
Scissors 5”electrician
Tweezers
Wipes alcohol
Retractable Permanent Marker
Standard Capped Permanent
SC and ST Compatible 2.5 mm
Ferrule Cleaning Sticks (10/pack)
LC 1.25 mm Ferrule Cleaning Sticks
(10/pack)
Package of Corning Wipes
(1Pak = 90sheets )
Bottle of Corning Fibre Cleaning
Fluid
Electrical Tape,black
UniCam Pretium Tool Bag with
Integrated Waste Receptacle and
Organized Foam Insert Interior
Standard UniCam Tool Bag

Item code

PFC

CTS-SF

Basic

TL-UCP

1 pce

-

-

TL-UC01
TEST-UNICAM-CTS-SF
VFL-350
VFL-A250
VFL-A125

1 pce
1 pce

1 pce
1 Set
1 pce
-

1 pce
-

FBC-15

1 pce

-

-

FBC-001
3201007-01
3206001-01

1 pce
1 pce

1 pce
1 pce
1 pce

1 pce
1 pce
1 pce

2104502-01

1 pce

1 pce

1 pce

100294-01
100312-01
1508001-01
Not sold separately
Not sold separately

1 pce
1 pce
1 Pack a
10pce
1 Pack a
10pce

1 pce
1 pce
6 pce
1 pce

1 pce
1 pce
6 pce
1 pce

-

-

-

-

2104493-01

1 pce

-

-

FCC-Cleaner-Fiber

1 pce

-

-

2104282-01

-

1 pce

1 pce

02-001860-001

1 pce

-

-

2104407-01

-

1 pce

1 pce

2104255-01
2104417-01

Ordering information:
Type Description
UniCam Pretium tool kit
Quantity/deliver unit
Ordering number

UniCam CTS-SF tool kit

UniCam basic tool kit

1/1

1/1

1/1

TKT-UNICAM-PFC

TKT-UNICAM-CTS-SF

TKT-UNICAM

Optional accessories:
Item
CTS adapter for UniCam® SC connectors
CTS adapter for UniCam® ST® compatible connectors
CTS adapter for UniCam® LC connectors
Jumper ST® compatible to SC SM simplex, 1m, FRNC
Jumper ST® compatible to LC SM simplex, 1m, FRNC

Item code
TER-CTS-SC
TER-CTS-ST
TER-CTS-LC
586101R3Z31001M
026101R2Z31001M

CTS
3 pcs
3 pcs
3 pcs
1 pce
1 pce

CTS-SF
3 pce
3 pcs
3 pcs
1 pce
1 pce

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2009 Corning Cable Systems. All rights reserved. Published in the EU.

Datasheet
®
Anaerobic ST compatible, FC, SC, LC/ January 2007

Product Family:

LANscape® Field installable connectors

Product:

ST® compatible, FC, SC and LC anaerobic-cure connectors

Fibre:

InfiniCor® SX+ OM3, InfiniCor® 600 OM2, InfiniCor® 300 OM1, SMF-28e™ OS2

Applications
The Corning Cable Systems’ anaerobic-cure all ceramic
ST® compatible, FC, SC and LC connectors are ideal
for all applications requiring field installed connectors,
like
fibre-to-the-desk,
fibre-to-the-machine
and
enterprise networks installations.
Description
The Corning Cable Systems’ anaerobic-cure multimode
and single-mode connectors combine the quick-cure
convenience of anaerobic adhesive with the
performances of epoxy and polish connectors.
The anaerobic adhesive uses a two-part epoxy-resin
curing process. The adhesive is first injected into the
connector’s ferrule, the fibre is dipped into the primer
and inserted into the ferrule, curing takes one minute
without the use of UV lamps or ovens.
Anaerobic connectors can be completely assembled
and polished in less than three minutes.

ST® compatible anaerobic-cure connector
MM 50/125µm OM2

Features /Benefits
-

Fast cure anaerobic adhesive: does not require electrical power supply.
Minimal tools required.
Hand polish: does not require polishing machine.
Reduced installation time: < 3 minutes (assembled and polished)
Typical insertion loss: 0.2 dB with physical contact polish.
ST® compatible, FC, SC connectors delivered in single connector’s bags including connector body with
preassembled ferrule, boots for 900 µm fibres and 2-mm, 3-mm jacketed cables, crimp rings for 2-mm, 3-mm
jacketed cables.
- LC connectors delivered in single connector’s bags including connector body with preassembled ferrule, boots
for 900 µm fibres and 2-mm, 3-mm jacketed cables, crimp rings for 1.6 – 2-mm, 3-mm jacketed cables.
- Available in 3 versions:
MM OM3/OM2: pack includes 2 sets of boots (Aqua OM3, Black OM2 to EIA/TIA-568-C.3 Draft 2006)
MM OM1: pack includes 1 set of boots (Beige to EIA/TIA-568-C.3 Draft 2006)
SM: pack includes 1 set of boots (Blue to EIA/TIA-568-C.3 Draft 2006 for LC connectors)*
- ST® compatible to TIA/EIA 604-2, FC to TIA/EIA 604-4, SC to TIA/EIA 604-3 and LC to TIA/EIA 604-10
®

* Boots for ST compatible, FC and SC single-mode connectors are white.

Characteristics
Connector type
Ferrule
Connector body
Insertion loss, typical PC (dB)
Reflectance Multi Mode (dB)
Reflectance SingleMode (dB)
Temperature cycling to FOTP-3

ST® comp./PC
Ceramic
Metal

FC/PC
Ceramic
Metal

SC/PC
Ceramic
Composite

LC/PC
Ceramic
Composite

0.2
≤ -26
≤ -40
∆IL ≤ 0.3 dB, -40 – +75 °C, 21 cycles

C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Datasheet
®
Anaerobic ST compatible, FC, SC, LC/ January 2007

Ordering information: Multimode connectors
ST® compatible
Ordering number
95-051-52-SP
95-101-52-SP

Description
ST® compatible MM Anaerobic, metal housing, black + aqua boots
ST® compatible MM Anaerobic, metal housing, beige boots

Fibre type
OM3/OM2
OM1

FC
Ordering number
95-051-61-SP
95-101-61-SP

Description
FC MM Anaerobic, metal housing, black + aqua boots
FC MM Anaerobic, metal housing, beige boots

Fibre type
OM3/OM2
OM1

SC
Ordering number
95-051-41-SP
95-101-41-SP

Description
SC MM Anaerobic, black housing, black + aqua boots
SC MM Anaerobic, beige housing, beige boots

Fibre type
OM3/OM2
OM1

LC
Ordering number
95-051-98-SP
95-101-98-SP

Description
LC MM Anaerobic, black housing, black + aqua boots
LC MM Anaerobic, beige housing, beige boots

Fibre type
OM3/OM2
OM1

Ordering information: Single-mode connectors
ST® compatible
Ordering number
95-201-52-SP

Description
ST® compatible SM Anaerobic, metal housing, white boots

Fibre type
OS2

FC
Ordering number
95-201-61-SP

Description
FC SM Anaerobic, metal housing, blue boots

Fibre type
OS2

SC
Ordering number
95-201-41-SP

Description
SC SM Anaerobic, blue housing, blue boots

Fibre type
OS2

LC
Ordering number
95-201-98-SP

Description
LC SM Anaerobic, blue housing, blue boots

Fibre type
OS2

C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Anaerobic connector tool kits/ February 2009

®

Product Family:

LANscape field installable connectors tool-kits

Product:

Anaerobic-cure connectors tool-kits

Fibre:

All Fibre Types

Applications
The Corning Cable Systems’ Anaerobic tool-kits are
intended for the installation of all Corning Cable
Systems’Anaerobic and Anaerobic GIC connectors.
Tool kits with different equipment are available also for
installation of a special group of connectors.
Description
Corning Cable Systems’tool kits for field installable
connectors provide with a collection of essential tools
required for tasks associated with the termination of
fibre optic cable. The tools are thoughtfully assembled
and are stored in compact and easy to carry cases that
are lined with a foam-padding material in order to
protect the high-quality tools.
The standard tool kit (TKT-ANAEROBIC2-EMEA)
TKT-ANAEROBIC2-EMEA tool kit
allows installation and polishing of multimode and
(Adhesive bottles may differ from photo)
single-mode all-ceramic anaerobic connectors as well
as of the anaerobic GIC connectors. All CCS’anaerobic
connector types can be installed with this kit: ST® compatible, FC, SC and LC. The kit contains consumables
for up to 500 connectors.
The TKT-ANAEROBIC2-25-EMEA is an economical alternative for installation of the only connectors with 2.5
mm diameter ferrules (ST® compatible, FC and SC). The kit contains consumables for up to 500 connectors.

The LC supplement kit TKT-ANAEROBIC2-S integrates the TKT-ANAEROBIC2-25-EMEA kit with the
additional tools necessary for LC termination.
The combined features of TKT-ANAEROBIC2-25-EMEA and TKT-ANAEROBIC2-S are equivalent to those of
TKT-ANAEROBIC2-EMEA.
A consumables set (TKT-ANAEROBIC2-C-EMEA) is available for replacing consumable materials like
polishing films and two components adhesive. The kit contains consumables for up to 500 connectors.
Features/Benefits
−
−
−
−
−

Compact and practical carrying bag
Full in-depth instruction included
All components necessary to install Anaerobic and Anaerobic GIC connectors are included.
Each of the tool kit includes consumables for the installation of up to 500 connectors
A consumables set including consumables for the installation of up to 500 connectors is available.

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Anaerobic connector tool kits/ February 2009

Tool kits contents
Item

Loctite#648 anaerobic
adhesive, 50ml
Loctite #7649 Primer
anaerobic, spray, 150ml
Syringe 3cc
Syringe tip 1.5mm
Polishing film clear, 0.2µm,
5”
Polishing film grey, 3µm, 6”
Polishing film yellow, 12µm,
5”
Polishing film white, 0.3µm,
5”
Puck polish. SC/ST/FC conn.
Puck-LC hand, spring loaded
Plate-polish. 6x6”(GIC conn.)
Pad rubber (all-cer. Conn.)
Crimp tool SC/ST/FC single
step
Crimp tool LC
Scribe, ruby (reversible
blade)
Stripper 6”wire Jensen tool
Stripper, No-nicks, 203µm
Fibre stripper, plier type
Gauge LC strip length
Gauge GIC RPP ST/SC strip
length
Razor blade single edge
Compressed air
Scissors 5”electrician
Tweezers
Wipes alcohol
Lint free wipes
Marker black
200x microscope 2.5
univ.adp
1.25 univ.adp for microscope
Battery 1.5V for microscope
Bottle 2.0 oz. with cap
Box, plastic clear
Spiral wrap 1/8”o.d.
Anaerobic procedure ISS 2

Item code

TKTTKTANAEROBIC2- ANAEROBIC2-CEMEA
EMEA
1pc
1pc

TKTANAEROBIC225-EMEA
1pc

TKTANAEROBIC2-S
-

1pc

1pc

1pc

-

100335-01
2104090-01
1506069-01

2 pcs
20 pcs
1 Pack / 50 pcs

1 Pack / 50 pcs

2 pcs
20 pcs
1 Pack / 50 pcs

-

2104004-02
2104071-01

1 Pack / 50 pcs
1 Pack / 15 pcs

1 Pack / 50 pcs
1 Pack / 15 pcs

1 Pack / 50 pcs
1 Pack / 15 pcs

-

2104072-01

1 Pack / 50 pcs

1 Pack / 50 pcs

1 Pack / 50 pcs

-

2104020-01
2104459-01
2104306-01

2 pcs
1 pce
2 pcs

-

2 pcs
2 pcs

1 pce
-

2104454-01
3201031-01

3 pcs
1 pce

-

3 pcs
1 pce

-

3201032-01
3233004-01

1 pce
1 pce

-

1 pce

1 pce
-

3206001-01
3205007-01
3205004-01
3201032-01
2104264-02

1 pce
1 pce
1 pce
1 pce
1 pce

1 pce
1 pce

1 pce
1 pce
1 pce
1 pce

1 pce
-

3224001-01*
2101005-01
100294-01
100312-01
1508001-01
3615001-01
2104007-01*
LSCOPE-9

3 pcs
1pce
1 pce
1 pce
12 pcs
1 pce
1 pce

1 pack
1 pce
-

3 pcs
1pce
1 pce
1 pce
12 pcs
1 pce
1 pce

-

2104375-01
1716016-01
1603004-03
1605059-01
1819001-02
SRP-006-160

1pce
3 pcs
2 pcs
1 pce
2 pcs
1 pce

3 pcs
1 pce

3 pcs
2 pcs
1 pce
1 pce

1 pce
2 pcs
1 pce

Note: All materials in the list of contents, except those marked with *, can be ordered separately

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Anaerobic connector tool kits/ February 2009

Ordering information:
Type Description
Quantity/deliver unit
Ordering number

Type Description
Quantity/deliver unit
Ordering number

Anaerobic tool kit for (ST/FC/SC/LC)
GIC and all-ceramic connectors

Consumables for anaerobic tool kits

1/1

1/1

TKT-ANAEROBIC2-EMEA

TKT-ANAEROBIC2-C-EMEA

Anaerobic tool kit for (ST/FC/SC) GIC
and all-ceramic conn. 2.5mm ferrule

Integration for TKT-ANAEROBIC2-25
for LC terminations

1/1

1/1

TKT-ANAEROBIC2-25-EMEA

TKT-ANAEROBIC2-S

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Buffer tube indoor and outdoor single fibre f an-out kits FAN-xxxx-xx / March 2007

®

Product Family:

LANscape Fan-out kits

Product:

Buffer tube indoor and outdoor single fibres fan-out-kits

Fibre:

Multimode and Single-Mode Fibres

Applications
The Corning Cable Systems’buffer-tube fan-out kits
are intended for the furcation of buffer tubes onto
900µm legs as required to field-install connectors on
bare fibres.
Different kits are available for applications on stranded
loose tube cables at indoor or outdoor cross-connection
points. In combination with the transition kits the indoor
buffer tubes fan-out kits can be also installed on single
maxi-tube cables.
Description
Corning Cable Systems’indoor and outdoor buffer tube
fan-out kits are specifically designed for the termination
of 6- and 12-fibres buffer tubes. These kits provide the
ultimate solution for the field termination of loose tube
cables by means of a compact easy to install assembly
not requiring additional hardware or space than that
required for terminating tight buffered cables.
Indoor and outdoor kits feature a 900µm fan-out
assembly that is colour coded to match the fibres
colour scheme (to Telcordia). The fan-out assembly is
available with 6- or 12-fibres units in lengths of 600 mm
(25-in.) or 1200 mm (47-in). These different lengths
provide the flexibility needed for installation in a variety
of hardware options.

Buffer tube fan-out kit

Buffer tube fan-out kit: furcation unit

Features / Benefits
−
−

−
−
−
−
−
−
−
−
−

Eliminates strain on fibres by isolating them from
tensile forces
Colour coded fan-out tubing to Telcordia:
6 fibres: blue, orange, green, brown, grey, white
12 fibres: blue, orange, green, brown, grey, white,
red, black, yellow, violet, pink, aqua
Snap-together furcation unit eliminates epoxy resin
for indoor kits.
Compact design.
Quick and easy to install.
Optimized for field termination of loose tube
cables.
Excellent fibre routing capabilities.
Bend radius protection designed into each unit.
Indoor temperature range: 0 °C – +70 °C.
Outdoor temperature range: -40 °C – +70 °C
Single maxi-tube cables fan-out extension kits
suitable for single maxi-tube cables containing
individual fibres or up to 5 bundles with up to 12
fibres each.

Buffer tube fan-out kit for single maxitube cables

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Data sheet
Buffer tube indoor and outdoor single fibre f an-out kits FAN-xxxx-xx / March 2007

Ordering information:
Indoor buffer tube fan-out kits
1
2
FAN – BT
–

Outdoor buffer tube fan-out kits
1
2
FAN – OD
–

Use the following options to construct the part number:
1 Select length of furcation length (900µm tubing)
25 = 600 mm (25-in.)
47 = 1200 mm (47-in.)

2 Select number of fibres
06 = 6 fibres
12 = 12 fibres

Examples:
FAN – BT47 – 06
Type designation: Indoor fan-out kit for 6 fibres, length of 900µm tubing = 1200 mm (47-in.).
FAN –OD25 – 12
Type designation: Closet fan-out kit for 12 fibres, length of 900µm tubing = 600 mm (25-in.).

Optional accessories:
Part Number
TKT-FANBT-A
TKT-FANBT-C

EST-END-01-SM
EST-END-01-MM

Description
Buffer tube fan-out assembly tool kit. Includes: buffer tube fan-out assembly fixture, case
for buffer tube fan-out assembly fixture.
Consumables for buffer tube fan-out assembly tool kit. Includes: buffer tube fan-out
clamp, Loctite 411 adhesive (3g), alcohol wipes (20 pcs), Kimwipes (1 pack).
Single maxi-tube fan-out kit for single-mode applications: includes funnel, yellow branch
tubing, transition heat-shrink sleeves and installation instructions.
Single maxi-tube fan-out kit for single-mode applications: includes funnel, orange branch
tubing, transition heat-shrink sleeves and installation instructions.

Co rn in g C a b l e S y st em s G mb H & C o . K G · L ei pz i ge r S t r a s s e 1 21 · 1 0 11 7 Be rlin , G e r m a ny
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c o r n i n g c a b l e s y s t e m s . c o m
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Datasheet
Ribbon fan-out kit RIB-FAN-12-xx / January 2007

Product Family:

LANscape® Fan-out kits

Product:

Single ribbon fan-out-kit

Fibre:

InfiniCor® SX+ OM3, InfiniCor® 600 OM2, InfiniCor® 300 OM1, SMF-28e™ OS2

Applications
The Corning Cable Systems’ ribbon fan-out kit is
intended for the furcation of a single ribbone (bare, in a
rectangular fan-out tubing or in a ribbon interconnect
cable) onto 900µm single fibre legs as required to fieldinstall single fibre connectors.
Description
The Corning Cable Systems’ ribbon fan-out kit is
specifically designed for the indoor termination of 12fibres ribbons bare as well as jacketed (fan-out tubing
or ribbon interconnect cable). This kit provide the
ultimate solution for the field termination onto single
fibre connectors by means of a compact, easy to install
assembly not requiring additional hardware or space
than that required for terminating tight buffered cables.

Single ribbon fan-out kit

The ribbon fan-out kit features a 900µm fan-out
assembly that is colour coded to match the fibres colour
scheme of the ribbon. The fan-out assembly is available
with 12-fibres units in lengths of 600 mm (25-in.) or 900
mm (36-in). These different lengths provide the
flexibility needed for installation in a variety of hardware
options.
Features / Benefits
−
−
−
−
−
−
−
−

Eliminates strain on fibres by isolating them from
tensile forces
Colour coded fan-out tubing for indoor use
Snap-together furcation unit eliminates epoxy resin.
Compact design.
Quick and easy to install.
Optimized for field termination of cables.
Excellent fibre routing capabilities.
Bend radius protection designed into each unit.

Ordering information:
Ordering number
RIB-FAN-12
RIB-FAN-12-36

Note:

Ribbon fan-out kit: components

Description
Ribbon fan-out kit 12x900µm tubing 600mm (25-in.) length
Ribbon fan-out kit 12x900µm tubing 900mm (36-in.)length

Tubing length
mm (in.)
600 (25)
900 (36)

900 mm (36-in.) length is only recommended if installing into connector modules;
600 mm (25-in.) length is recommended for connector panels and other Corning Cable Systems
hardware.

C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Datasheet
Spider fan-out kits SFK-x-xx-xxx-x / January 2007

Product Family:

LANscape® Fan-out kits

Product:

Spider fan-out-kits

Fibre:

InfiniCor® SX+ OM3, InfiniCor® 600 OM2, InfiniCor® 300 OM1, SMF-28e™ OS2

Applications
The Corning Cable Systems’ spider fan-out kits are
intended for the furcation of loose tube or tight buffered
cables buffer tubes onto ruggedized legs to realize
multifibres cable assemblies to be used for direct
connections without use of patch panels.
Different kits are available for application on loose tube,
tight buffered or ribbon cables.
Description
Corning Cable Systems’ spider fan-out kits are a low
cost termination option for multifibre cables. These kits
are designed for both factory and field termination of
tight-buffered, loose tube (with 4 to 24 fibres) and single
tube ribbon (24 to 96 fibres) non-armoured cables.
These kits provide a modular, easy installable solution
based on a simple step-by-step assembly that grants a
successful installation. Installation of spider fan-out kits
eliminates the need for patch panels at low-cost
termination points.
The spider fan-out kits terminate and provide pull-out
protection for single fibres (tight buffered 900µm or bare
fibres 250µm) or bare 12-fibres ribbons; the single
fibres or the ribbons are threaded into the modular
inserts which consist of a composite assembly
securing, for single fibres, six 1-meter lengths of fan-out
tubing, and for 12-fibre ribbons two 1-meter lengths of
rectangular fan out tubing. The fan-out tubing (for single
fibre as well as for ribbon) provide three layers of
protection consisting of a Teflon inner tube (into which
the fibre or the ribbon is inserted) an aramid yarn
strenght member and an outer protective PVC Jacket.
The fan-out insert snaps into the main spider body
which is then enclosed within the outer housing.

Spider fan-out MM OM1/OM2 on
tight buffered cable

Spider fan-out kit SM on loose tube
cable

Features / Benefits
−
−
−
−
−
−

Modular, compact design.
No special tool or heat-shrink sleeve
Field or factory termination
Fan-out tubing length of one meter provides flexible
installation
Cost effective for splicing and terminating hardware
Non-metallic/high strength, rugged, composite
material.
Ribbon spider fan-out kit MM OM3

C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Datasheet
Spider fan-out kits SFK-x-xx-xxx-x / January 2007

Specifications :

Fibre
count
6 to 12

Loose tube/Single tube cable
(bare fibre / 250µm)
Length
Diameter
mm (in.)
mm (in.)
146 (5.75)
28 (1.1)

Mic / A-VQ(BN)H
(tight buffered fibre / 900µm)
Length
Diameter
mm (in.)
mm (in.)
121 (4.75)
19 (0.75)

Single tube ribbon cable
(12-fibres ribbon)
Length
Diameter
mm (in.)
mm (in.)
–
–

13 to 24

146 (5.75)

28 (1.1)

146 (5.75)

28 (1.1)

–

–

24 to 96

–

–

–

–

146 (5.75)

28 (1.1)

Acceptable cable outer diameter:

Fibre
count
6 to 12

Loose tube/Single tube cable
(bare fibre / 250µm)
Min. O.D.
Max. O.D.
mm (in.)
mm (in.)
8.6 (0.34)
15.7 (0.62)

Mic / A-VQ(BN)H
(tight buffered fibre / 900µm)
Min. O.D.
Max. O.D.
mm (in.)
mm (in.)
4.6 (0.18)
7.1 (0.28)

Single tube ribbon cable
(12-fibres ribbon)
Min. O.D.
Max. O.D.
mm (in.)
mm (in.)
–
–

13 to 24

8.6 (0.34)

15.7 (0.62)

6.6 (0.26)

10.9 (0.43)

–

–

24 to 96

–

–

–

–

8.6 (0.34)

15.7 (0.62)

Ordering information:
H indicates the RoHS compliance
1
SFK –

2
–

3
–

4
–

H

Use the following options to construct the part number:
1 Select length of furcation length (900µm
tubing)
P = 3mm (single fibre) or rectangular (ribbon) fanout tubing
P2 = 2mm (single fibre) fan-out tubing
2 Select number of fibres
06 = up to 6 single fibres
12 = up to 12 single fibres
18 = up to 18 single fibres
24 = up to 24 single fibres or 2 ribbons (24 fibres)
48 = up to 4 ribbons (48 fibres)
72 = up to 6 ribbons (72 fibres)
96 = up to 8 ribbons (96 fibres)

3 Select fibre type
900 = accepts 900µm tight buffered fibres
250 = accepts 250µm bare fibres
RIB = accepts 12 fibres ribbon
4 Select fan-out tubing colour
M = Orange (62.5µm or standard 50µm
multimode)
S = Yellow (single-mode)
A = Aqua (laser optimized 50µm multimode)

Examples:
SFK – P – 06 – 900 – SH
Type designation: Spider fan-out kit for 6x 900µm single-mode fibres, 6 fan-out tubings 3mm diameter, yellow.
SFK – P2 – 24 – 250 – AH
Type designation: Spider fan-out kit for 24x250µm multimode 50µm laser optimized fibres (OM3), 24 fan-out
tubings 2mm in diameter, aqua.
SFK – P – 24 – RIB –MH
Type designation: Spider fan-out kit for 2xribbon (24 fibres) multimode 50µm or 62.5µm fibres (OM3), 2
rectangular fan-out tubings, orange.

C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Datasheet
Spider fan-out kits SFK-x-xx-xxx-x / January 2007

Optional accessories:
Part Number
Description
2104148-01
6 fibres insert plug for bare fibres (250µm) orange (62.5µm or standard 50µm multimode).
2104149-01
6 fibres insert plug for tight buffered fibres (900µm) orange (62.5µm or standard 50µm
multimode).
2104150-01
6 fibres insert plug for bare fibres (250µm) yellow (single-mode).
2104151-01
6 fibres insert plug for tight buffered fibres (900µm) yellow (single-mode).
SFK-P-IH-RIB-A
SFK-P-IV -RIB-A
SFK-P-IH-RIB-M
SFK-P-IV-RIB-M
SFK-P-IH-RIB-S
SFK-P-IV-RIB-S

2 horizontal ribbons insert plug aqua (multimode 50µm laser optimized fibres)
2 vertical ribbons insert plug aqua (multimode 50µm laser optimized fibres)
2 ribbons horizontal insert plug orange (62.5µm or standard 50µm multimode).
2 ribbons horizontal insert plug orange (62.5µm or standard 50µm multimode).
2 ribbons horizontal insert plug yellow (single mode).
2 ribbons horizontal insert plug yellow (single mode).

2104189-01

Blank plug

C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Datasheet
CamSplice™ 95-000-04-xxx / January 2007

Product Family:

LANscape® CamSplice™ no-adhesive mechanical splice

Product:

CamSplice™ no-adhesive mechanical splice

Fibre:

InfiniCor® SX+ OM3, InfiniCor® 600 OM2, InfiniCor® 300 OM1, SMF-28e™ OS2

Applications
Corning Cable Systems’ CamSplice™ no-adhesive
mechanical splices are especially indicated for
emergency restoration and lab splicing for temporary
system testing. They offer also a simple solution for
those cases where the use of a fusion splice machine is
not practicable.
Description
Corning Cable Systems’ CamSplice™ is a simple, craftfriendly mechanical splice for both multimode and
single-mode fibres. It features a “cam” locking
mechanism, which requires no adhesive. The
CamSplice™ mechanical splice incorporate a unique,
patented fibre alignment method that self-centres the
fibres and provides extremely accurate alignment.
Average “blind” (non-tuned) splice loss for the
CamSplice™ mechanical splice is specified at 0.3 dB
with a minimum loss less than 0.15 dB. There is only
one part for 250 µm to 250 µm, 250 µm to 900 µm or
900 µm to 900 µm applications (one size fits all).
The CamSplice™ mechanical splice requires minimal
training and few accessories to assemble. The
assembly process involves stripping and cleaving
fibres, inserting the fibres into the splice part until they
touch and turning the cams to secure the fibre. The
process does not involve any adhesives or special
tools, although an optional assembly fixture is
recommended. A typical installation takes less than two
minutes. A compact, self-contained tool kit is available
with standard tools including the optional the assembly
fixture.

CamSplice™ and antitorsion
CamSplice™

CamSplice™ assembly tool

Completed splices fit in Corning Cable Systems and
many other industry standard splice trays.
Features / Benefits
−
−
−
−
−
−
−
−
−

No adhesive or epoxy required
Universal: one part fits all fibre coatings
Re-mateable, tunable.
Self centring alignment mechanism.
Antitorsion option with lead-in tubes for securing
900µm tight buffered fibres.
Pre-inserted index-matching gel.
No stress in fibre alignment area.
Small assembly fixture recommended, but optional.
Fits in most industry standard splice trays.

C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.

Datasheet
CamSplice™ 95-000-04-xxx / January 2007

Characteristics
Dimensions LxW: mm (in.)
Typical splice loss: dB
Typical “blind” splice loss: dB
Reflectance (flat cleave): dB
Reflectance (angled cleave): dB
Tensile strength: N
Temperature range:
Vibration

44.0 x 4.2 (1.73 x 0.17)
0.15
0.3
≤ -45 dB
≤ -60 dB
2.25
-40 – +75 °C, ∆IL ≤ 0.1 dB average
10 – 55 Hz, amplitude max. 1.52 m, 3 axis, 2 h each, ∆IL ≤ 0.5 dB

Ordering information:
Description

Ordering number
95-000-04
95-000-04-ATC*

CamSplice™ mechanical splice
Antitorsion CamSplice™ mechanical splice for 900µm applications

Quantity/ delivery
unit
6/1
900 (36)

* Once crimped the antitorsion CamSplice™ is not re-mateable
Optional accessories:
Part Number
Description
TKT-100-01
CamSplice™ tool kit, includes CamSplice™ assembly fixture, fibre coating stripping tool.
TKT-100-02
CamSplice™ tool kit with cleaver, includes CamSplice™ assembly fixture, fibre coating
stripping tool and Score & Snap Cleaver.
2104040-01
2104200-01

CamSplice™ assembly fixture.
Crimp tool for antitorsion CamSplice™ mechanical splice

FBC-001
FBC-006

Score & Snap cleaver.
Precision fibre cleaver.

Tool kits contents
Item
CamSplice™ assembly tool
Fibre cleaver, score & snap
Stripper 6” wire Jensen tool
Stripper, No-nicks, 203µm
Fibre stripper, plier type
Scissors 5” electrician
Marker black
Tweezers
Black tape, electrical,3/4”x20’
Wipes alcohol
Bottle 60 ml dispensing
Book of numbers 0 - 9
Instructions CamSplice™ assembly
Instructions FBC-001 cleaver
Instructions fibre stripping tool
Instructions buffer stripping tool
Instructions stripper No-nicks, 203µm

Item code
2104040-01
FBC-001
3206001-01
3205007-01
3205004-01
100294-01
2104007-01*
100312-01
2104047-01
1508001-01
1604003-01*
100297-01
SRP-006-038
SRP-001-040
SRP-005-006
SRP-005-005
SRP-004-036

TKT-100-01
1 pce
1 pce
1 pce
1 pce
1 pce
1 pce
1 pce
1 pce
6 pcs
1 pce
1 pce
1 pce
1 pce
1 pce
1 pce

TKT-100-02
1 pce
1 pce
1 pce
1 pce
1 pce
1 pce
1 pce
1 pce
1 pce
6 pcs
1 pce
1 pce
1 pce
1 pce
1 pce
1 pce
1 pce

Note: All items in the content lists, except those marked with *, can be ordered separately

C o r n i n g C a b l e S ys t e m s G m b H & C o . K G · R o t h e r s t r a s s e 2 1 · 1 0 2 4 5 B e r l i n , G e r m a n y
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F AX : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · w w w . c or ni ngc a bl e s ys t e m s . c om
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior
notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. © 2006 Corning Cable Systems. All rights reserved. Published in the EU.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2010:09:15 13:15:04+02:00
Create Date                     : 2010:09:15 13:13:19+02:00
Metadata Date                   : 2010:09:15 13:15:04+02:00
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Title                           : Spec Sheet_A4_V_final_Layout 1
Creator                         : KuhlemanS
Document ID                     : uuid:aec20fe6-ac62-4175-822b-00d5fc61f3c6
Instance ID                     : uuid:6e7a090f-a303-44eb-9f24-bd7c0d501167
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Has XFA                         : No
Page Count                      : 31
Author                          : KuhlemanS
EXIF Metadata provided by EXIF.tools

Navigation menu