Keyspan LIPA 8 09 685237 Catalog
648266-Catalog 648266-Catalog 648266-Catalog Batch9 unilog cesco-content
2014-09-05
: Pdf 685237-Catalog 685237-Catalog 784572 Batch7 unilog
Open the PDF directly: View PDF .
Page Count: 20
Download | |
Open PDF In Browser | View PDF |
Meter Mounting Equipment LIPA National Grid 2 MILBANK OVERVIEW Charles A. Milbank 1879-1966 Bill Martin 1916-1998 Robert F. Waldrop 1922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman Milbank–Quality Metering Products for 80 Years M ilbank Manufacturing Company was established in 1927 by Charles A. Milbank. Originally, the company manufactured high voltage switches; however, by 1941 Milbank devoted itself primarily to the manufacture of sheet metal enclosures and related equipment for the electrical generation and distribution industry. Today we are an industry leader in the manufacture of electrical meter sockets. Through a national network of manufacturer’s representatives we provide wholesale electrical distributors with quality electrical products for the utility, contractor, industrial and OEM markets. As the meter standards have changed, Milbank has been successful in adapting its product line to these changes. Our full scale engineering department designs products to meet customer specifications and satisfy all utility requirements. Milbank’s employee base of over 1,000 workers, along with our five manufacturing facilities com- prising almost 550,000 square feet give us the flexibility to schedule, produce, and ship orders quickly. Currently, Milbank manufactures over 10,000 different catalog items, and this list continues to grow. Our unique product offering includes: Residential & Commercial Meter Sockets; Residential & Commercial Meter Pedestals; RV/MH Power Outlets, Service Pedestals, and Transformers; Commercial & Industrial Electrical Enclosures; Circuit Breakers; Disconnects & Safety Switches; Safety Sockets; Utility & Residential Secondary Pedestals; Hubs, and related accessories. If you don’t find a unit in this catalog to service your needs, send us your specifications and we will be happy to work with you. Our success has come from a loyal customer base that can rely on us to build quality products at a fair price in a timely manner. Our willingness and ability to design and produce new products to meet our customer demands is 2 an important factor to remain competitive in today’s electrical market. Milbank has been serving the electric utility & wholesale distribution industries for 80 years with innovative, quality engineered products. So remember us for all of your meter mounting and related requirements, and we will be happy to serve you as we have in the past–with dependable service and quality products! We take great pride in being one of the few family-owned businesses left in our industry. We are a third generation run business and truly believe that... FAMILY MAKES A DIFFERENCE! TABLE OF CONTENTS CATALOG NUMBER LOGIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 DISCONNECTS 30 & 60 amp – Fusible / Non-Fusible – Air Conditioner Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 AC Disconnect / Spa Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 SINGLE POSITION 200 amp – Ringless – 5 & 7 Terminal – Lever Bypass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 320 amp Continuous – 400 amp Max – 5 Terminal – Jaw Clamping Lever – Ringless – 600 vac . . . . . . . . . . . . . .8 100-320 amp – 5 & 7 Terminal – Lever Bypass with Main Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 MULTIPLE POSITION 100 / 200 amp – 5 Terminal – Horizontal Gangs – Ringless–600 vac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 CONDOMINIUM METER MAIN 200 amp – 5 Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 TRANSFORMER RATED 400 / 800 amp – Trans-S Cabinets – Overhead / Underground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 MISCELLANEOUS Milbank Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Ampacity Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Energization of Electrical Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Other Milbank Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-17 INDEX CAT.NO. PG 6003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 A7514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 A7515 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 A7516 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 A7517 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 A7518 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 A7551 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 A8110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 A8111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 A8112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 A9064 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 CP-21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 K1190 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 K1350 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 K1539 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 K1540 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 K1541 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 K3082 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 K3083 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 K3441 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 K3442 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 K8180 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 M5-144 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 S8324 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 U1854-XL-QG-BLG-LIS . . . . . . . . . . . . . . . . . . . . . . . .7 U3042-XL-QG-BLG-LIS . . . . . . . . . . . . . . . . . . . . . . . .7 U3800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 U3801 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3 CAT.NO. PG U3830 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 U3860 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 U3822-20GR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 U3986-XL-100-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . .11 U3986-XL-150-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . .11 U3986-XL-200-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . .11 U4142-XT-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 U4143-XT-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 U4144-XT-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 U4154-XT-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 U4163-XT-11-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 U4165-XT-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 U4166-XT-Z21-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . .12 U4302-X-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 U4303-X-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 U4304-X-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 U4305-X-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 U4306-X-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 U4523-X-Z11-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 U4554-X-Z21-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 U4881-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 U4881-O-50GB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 U4881-O-60GB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 U5059-X-2/150-K3L-LIS . . . . . . . . . . . . . . . . . . . . . . .11 U5080-RXL-200-LIS . . . . . . . . . . . . . . . . . . . . . . . . . .11 U5703-X-K3L-K2L-LIS . . . . . . . . . . . . . . . . . . . . . . . . .8 UC4278-XL-21-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . .12 UC4279-XL-21-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . .12 3 4 CATALOG NUMBER LOGIC 4 30 & 60 AMP–FUSIBLE / NON-FUSIBLE–AIR CONDITIONER DISCONNECTS 5 DISCONNECTS U3801 U3800 U3860 (No deadfront required) PROFILE Milbankʼs air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements in the NEC and, also, complies with article 440-14 in the NEC. To insure the safest conditions, we designed our disconnect pullers to be removable or they may be reinstalled in the off position. Another safety feature is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading finish. TECHNICAL INFORMATION AMP TYPE CATALOG NUMBER MAX WT. H.P. @ # 30 FUSIBLE U3830 3 2.7 60 FUSIBLE U3860 10 3.3 60 NONFUSIBLE U3800 10 3.25 60 NONFUSIBLE U3801 10 2.5 LINE & LOAD WIRE RANGE GROUND WIRE RANGE DIMENSIONS WIRE RATING CU °C CU AL CU/AL D" W" H" #14-#3 AWG #14-#3 AWG #14-#2 AWG #14-#3 AWG #14-#3 AWG #14-#3 AWG #12-#2 AWG #14-#3 AWG #14-3 AWG 2-5/8 5 7 #14-3 AWG 3 5 #14-3 AWG 3 5 #14-3 AWG 2-3/8 5 AL °C 60°/75° 60°/75° 91⁄4 60°/75° 60°/75° 8 60°/75° 60°/75° 6-3/4 60°/75° 60°/75° U/L listed as Enclosed Pullout Switch Type 3R Rainproof 1∅, 240 VAC Six one-inch concentric knockouts Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 5 AC DISCONNECT / SPA BOX Combination AC Disconnect / 20 Amp GFCI Receptacle–Together in 1 Box DISCONNECTS 6 • Meets NEC # 210.63 Requirements * • UL Listed as Power Outlet • Type 3R Enclosure • In-Use Cover** • Duplex Ground Connector • 1” Concentric Knockouts * NEC® #210.63 Heating, Air- 60 amp, Non-Fused AC Disconnect Type 3R Enclosure with In-Use Cover GFCI RECEPTACLE • 20 amp • Reset/Test Button • Padlock provision U3822-20GR AMP 60 TYPE CATALOG MAX WT. NUMBER H.P. @ # NONFUSIBLE U3822-20GR 10 LINE & LOAD CONNECTOR WIRE RANGE 6 Conditioning and Refrigeration Equipment Outlet. ...The receptacle shall be located on the same level and within 7.5 m (25 ft.) of the heating, airconditioning and refrigeration equipment. * NEC® #210.08 Ground-Fault Circuit– Interruptor protection for personnel. AC DISCONNECT • 1∅, 240 Volt • 60 amp, Non-Fused Duplex 20 amp GFCI Receptacle GROUND CONNECTOR WIRE RANGE CU AL CU/AL #14-#2 AWG #12-#2 AWG #14-4 AWG DIMENSIONS WIRE RATING D″ CU °C W″ H″ AL °C 4.8 5.25 7.4 60°/75° 60°/75° To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position. All units are designed with a padlock provision on the cover for security. **Note: U3822-20GR cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle). *Reprinted with permission from NFPA 70-2002, National Electrical Code®, Copyright 2001, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code® and NEC® are registered trademarks of the National Fire Protection Association, Quincy, MA. Hot Tub Disconnect or Sub Panel Breaker Enclosure–Type 3R Spa Box with GFCI Protection • • • • • • • • • • • 240 volt ground fault protection UL listed, Type 3R rainproof Milbank reliability Easy installation 2 pole, 50 or 60 amp GFCI breaker protection Compact size: 8-1/2” H x 7-1/2” W x 3-3/4” D 3 or 4 wire installation 1∅, 120 / 240 VAC Standard package of 12 2 extra one-pole breaker spaces 100 amp overall rating Sub Panel Breaker Enclosure • Use as a 100 amp, 4 circuit sub panel enclosure • U4881-O has provision for (2) 2-pole or (4) 1-pole small frame breakers U4881-O-50GB AMP TYPE CATALOG NUMBER WT. @ # U4881-O LINE & LOAD CONNECTOR WIRE RANGE Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. GROUND CONNECTOR WIRE RANGE DIMENSIONS CU AL CU/AL D″ W″ H″ 7 #14-1/0 #14-1/0 #14-1/0 3 3⁄4 71⁄2 81⁄2 50 BREAKER U4881-O-50GB 8 #14-1/0 #14-1/0 #14-1/0 3 3⁄4 71⁄2 81⁄2 60 BREAKER U4881-O-60GB 8 #14-1/0 #14-1/0 #14-1/0 3 3⁄4 71⁄2 81⁄2 – BREAKER PROVISION 6 200 AMP – RINGLESS – 5 & 7 TERMINAL – LEVER BYPASS 4 2 3 55 SINGLE POSITION 1 4 6 U3042-XL-QG-BLG-LIS U1854-XL-QG-BLG-LIS 200 AMP–5 TERMINAL–RINGLESS–1∅3W CONNECTORS AMP SERVICE 200 OH/UG CATALOG NUMBER HUB BY- DIMENSIONS LOAD PASS D″ W″ H″ CONCENTRIC K.O.ʼS CU/AL LINE U3042-XL-QG-BLG-LIS C.P. #6-350 kcmil #6-350 LEVER 4 kcmil 7 ⁄8 13 19 1 2 3 1 3 ⁄2 2 3 4 5 3 1 ⁄4 6 1 1 4, 2 ⁄ ⁄ HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever on the U3042 supplies clamping action on meter spades and also operates bypass device. INSULATED NEUTRAL: For field installed insulated neutral order as extra catalog number K1047. BARREL LOCK (-BLG): Has provision for barrel lock with guard. 200 AMP–7 TERMINAL–RINGLESS–3∅4W CONNECTORS AMP SERVICE 200 OH/UG CATALOG NUMBER HUB BY- DIMENSIONS LOAD PASS D″ W″ H″ CONCENTRIC K.O.ʼS CU/AL LINE U1854-XL-QG-BLG-LIS C.P. #6-350 kcmil #6-350 LEVER 4 kcmil 7 ⁄8 13 19 1 2 3 1 2 ⁄2 3 3 4 5 3 1 ⁄4 6 1 1 4, 2 ⁄ ⁄ HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. INSULATED NEUTRAL: For field installed insulated neutral order as extra catalog number K1047. BARREL LOCK (-BLG): Has provision for barrel lock with guard. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 7 7 320 AMP CONTINUOUS–400 AMP MAX–5 TERMINAL JAW CLAMPING LEVER–RINGLESS–600 VAC SINGLE POSITION 8 5073 U5073-X-K3L-K2L-LIS 320 AMP–5 TERMINAL–RINGLESS–1∅3W–600 VAC CONNECTORS SERVICE OH/UG CATALOG NUMBER U5073-X-K3L-K2L-LIS* HUB LINE C.P. BY- DIMENSIONS PASS LOAD D″ W″ H″ CONCENTRIC K.O.ʼS CU/AL #4-600 or (2) 1/0 -250 (twin) 350 LEVER 7 4 ⁄8 15 31 1 ⁄2 1 3 2 3 3 3 4 5 3 1 ⁄4 6 1 1 4, 2 ⁄ ⁄ BYPASS: The lever supplies the clamping action and also operates bypass device. CONNECTORS: Factory installed connectors - line side - single conductor #4-600 kcmil or 2 conductors 1/0 - 250 kcmil load side - twin connectors #6-350 kcmil * UL LISTED based on parallel 250 kcmil connectors maximum. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 8 100/200 AMP–5 TERMINAL–HORIZONTAL GANGS–RINGLESS–600 VAC 2 1 1 MULTIPLE POSITION U4142 3 4 3 5 4 U4142-XT-LIS 100 / 200 AMP PER POSITION–5 TERMINAL–RESIDENTIAL / COMMERCIAL AMP CATALOG NUMBER 100/200 U4142-XT-LIS NO. OF HUB SERVICE POS. 2 C.P. OH/UG 100/200 U4143-XT-LIS 3 C.P. OH/UG 100/200 U4144-XT-LIS 4 C.P. OH/UG CONNECTORS CU/AL LINE LOAD 3/8 x 16″ STUDS 3/8 x 16″ STUDS 3/8 x 16″ STUDS #6-350 kcmil #6-350 kcmil #6-350 kcmil DIMENSIONS BYPASS D″ LEVER 6 32 LEVER 6 42 3 LEVER 6 52 W″ H″ 1 ⁄8 251⁄4 1 CONCENTRIC K.O.ʼS 1 1 2 2 3 1 4 2 1 2 1 2 ⁄16 25 ⁄4 2 1 2 ⁄4 251⁄4 ⁄2 ⁄2 ⁄2 ⁄2 4 5 6 1 1 1 4, 2 ⁄ ⁄ – 1 1 1 4, 2 ⁄ ⁄ – 1 1 1 4, 2 – 2 1 4 2 1 4 2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄ ⁄ HUBS: Units are supplied with two closing plates as standard. To order hubs as extra refer to the hub chart on the accessory page. LEVER BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Line wire sections are supplied with 3/8″ – 16 hex head nuts with Belleville washers. For single lug connector kits, order as extra: K1539 (350 kcmil) or K1540 (600 kcmil). For twin lug connectors: K1350 (350 kcmil) or K1541 (600 kcmil). Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 9 9 10 200 AMP–5 TERMINAL–CONDOMINIUM METER MAIN 1 2 2 2 2 2 2 3 1 2 POSITION 2 2 2 2 2 2 3 3 POSITION U4304-X-LIS METER MAIN 3 2 2 2 1 1 2 2 2 3 4-6 POSITION 200 AMP–5 TERMINAL–RINGLESS–LEVER BYPASS–CONDO METER MAIN–1Ø3W CATALOG NUMBER CONNECTORS BYPASS HUB LINE DIMENSIONS LOAD D” W” 3 CONCENTRIC K.O.ʼS H” 1 2 3 1 1 4, 2 U4302-X-LIS* LEVER C.P. 3/8”-16 STUD BREAKER 6 27 ⁄4 48 4 2 U4303-X-LIS LEVER C.P. 3/8”-16 STUD BREAKER 6 27 3⁄4 60 4 2 U4304-X-LIS LEVER C.P. 3/8”-16 STUD BREAKER 6 45 48 4 2 U4305-X-LIS LEVER C.P. 3/8”-16 STUD BREAKER 6 45 60 4 2 U4306-X-LIS LEVER C.P. 3/8”-16 STUD BREAKER 6 45 60 4 2 ⁄ ⁄ 1 1 ⁄4, ⁄2 1 1 ⁄4, ⁄2 1 1 ⁄4, ⁄2 1 1 ⁄4, ⁄2 HUBS: Units are supplied with 2 closing plates as standard. To order hubs as extra refer to the hub chart on the accessory page. CONNECTORS: Line wire sections are supplied with 3/8″ - 16 hex head nuts with Belleville washers. For single lug connector kits, order as extra: K1539 (350 kcmil) or K1540 (600 kcmil). For twin lug connectors: K1350 (350 kcmil) or K1541 (600 kcmil.) LEVER BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. REPLACEMENT LOCKING PIN: For replacement locking pin order part number Z816559-SC (1 pin). BREAKERS: Units have provision for (1) double pole main per meter position. Breakers NOT included – order as extra. See chart below. * 2 Position Condominium meter main has additional 3” knockout (bottom left section). PLUG-IN BREAKER COMPATIBILITY CHART CUTLER-HAMMER AMPS MILBANK (WESTINGHOUSE / BRYANT) 125-200 ≤ 100 SIEMENS SIEMENS MURRAY / (ITE) CROUSE-HINDS G.E. SQ-D — Q BR / BJ / HQP — MD Q LINE Q QUICKLAG P / BR / HQP QP MP Q LINE HOMELINE 10 Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 100-320 AMP—5 & 7 TERMINAL—LEVER BYPASS WITH MAIN BREAKER 4 2 1 5 3 SINGLE POSITION 1 6 4 3986 5080 5059 U5059-X-2/150-K3L-LIS U3986-XL-200-LIS 100 / 150 / 200 / 320 AMP—5 & 7 TERMINAL—WITH MAIN BREAKER—RINGLESS—LEVER BYPASS NO. OF AMP TERM. 5 5 5 7 7 5 CONNECTORS CATALOG NUMBER HUB SERVICE 100 U3986-XL-100-LIS C.P. OH/UG 150 U3986-XL-150-LIS C.P. OH/UG 200 U3986-XL-200-LIS C.P. OH/UG 150 U5080-RXL-150-LIS C.P. OH/UG 200 U5080-RXL-200-LIS C.P. OH/UG 320 U5059-X-2/150-K3L-LIS* C.P. UG CU/AL LINE LOAD #6-350 kcmil #6-350 kcmil #6-350 kcmil #6-350 kcmil #6-350 kcmil #4600 kcmil #1-300 kcmil #1-300 kcmil #1-300 kcmil #1-300 kcmil #1-300 kcmil #1/0-300 kcmil BYPASS DIMENSIONS D″ 7 LEVER 4 ⁄8 7 LEVER 4 ⁄8 7 LEVER 4 ⁄8 7 LEVER 4 ⁄8 W″ 13 13 13 13 H″ 1 2 34 1 1 1 34 34 34 7 13 34 7 15 42 LEVER 4 LEVER 4 ⁄8 ⁄8 CONCENTRIC K.O.ʼS 2 ⁄2 1 2 ⁄2 1 2 ⁄2 1 2 ⁄2 1 2 ⁄2 3 2 2 ⁄2 ⁄2 3 4 5 3 3 1 1 1 4, 2 3 3 1 1 1 4, 2 1 1 4, 2 ⁄4 ⁄4 6 ⁄ ⁄ ⁄ ⁄ 1 3 3 1 1 3 3 1 1 1 4, 2 1 ⁄4 1 1 4, 2 1 1 4, 2 --- 2 2 ⁄2 ⁄2 1 3 3 3 3 1 2 ⁄2 ⁄4 ⁄4 ⁄4 ⁄ ⁄ ⁄ ⁄ ⁄ ⁄ ⁄ ⁄ HUBS: Unit is supplied with closing plates as standard. To order hubs as extra, refer to the hub chart on the accessory page. LEVER BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Line wire sections are supplied with #6-350 kcmil lay-in connectors. BREAKER: U3986 has factory installed double pole Milbank UQFB-100-X1, UQFB-150-X1 or UQFB-200-X1 main breaker. U5080 has factory installed 3 pole Milbank UQFB-3200 main breaker. * Side Wireway Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 11 11 12 400 / 800 AMP–TRANS-S CABINETS–OVERHEAD / UNDERGROUND 2 2 5 4 3 3 4154 4165 4 4163 4166 5 4 3 3 4 2 U4154-XT-LIS U4163-XT-11-LIS 1 5 4554 4523 5 4 3 4 4 3 Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 2 4278 4279 4 5 200 / 400 / 800 AMP—METERED—TRANS-S CABINET–1∅3W OR 3∅3W–600 VAC CONNECTORS TRANSFORMER RATED PHASE TERM CATALOG NUMBER BY- DIMENSIONS LINE LOAD PASS D″ W″ H″ CONCENTRIC K.O.ʼS CU/AL AMP HUB SERVICE 1∅ 6 U4554-X-Z21-LIS C.P. OH/UG 200/400 1∅ 6 U4166-XT-Z21-LIS C.P. OH/UG 400/800 3∅ 13 U4523-X-Z11-LIS C.P. OH/UG 200/400 3∅ 13 U4163-XT-11-LIS C.P. OH/UG 400/800 SEE NOTE* #4-600 kcmil SEE NOTE* #4-600 kcmil #4-600 kcmil #4-600 kcmil #4-600 kcmil #4-600 kcmil 1 2* 3 4 5 6 4 4 1 1 — 4 4 1 1 — 1 — 1 — NONE 10 21 41 — 3 NONE 10 26 51 — 3 4 4 1 4 4 1 ⁄8 ⁄8 NONE 10 21 41 — 3 NONE 10 26 51 — 3 ⁄8 ⁄8 ⁄4 ⁄4 ⁄4 ⁄4 * This is a 3/8” hole with plastic plug, not a concentric knock-out. Lugs provided – rated up to single 600 kcmil - #4 awg. Short circuit current withstand capability is 50K symmetrical amps. Furnished with 1/2” - 13 studs, washers and hex nuts with conical sems for CT mounting. *Only 200/400 amp units have elliptical lug - 1-#4-600 kcmil or up to 2-1/0-250 kcmil. 400 / 800 AMP—UNMETERED ENCLOSURE CONNECTORS CATALOG NUMBER HUB SERVICE U4165-XT-LIS C.P. OH/UG PHASE 1∅ 3∅ U4154-XT-LIS C.P. OH/UG CU/AL LINE LOAD #4-600 kcmil #4-600 kcmil #4-600 kcmil #4-600 kcmil DIMENSIONS CONCENTRIC K.O.ʼS BYPASS D″ W″ H″ 1 NONE 10 26 51 NONE 10 26 51 2* 3 4 — 3 4 4 — 3 ⁄8 ⁄8 4 5 6 1 — 1 — 1 4 1 ⁄4 ⁄4 * This is a 3/8” hole with plastic plug, not a concentric knock-out. Lugs provided – rated up to single 600 kcmil - #4 awg. 20 AMP—1 PIECE COVER—REMOTE SOCKETS—RINGLESS—1∅—3∅ ∗ PHASE TERM CATALOG NUMBER HUB SERVICE CONNECTORS BY- DIMENSIONS PASS D″ W″ H″ CU/AL 2 3 4 5 6 1 1 1 1 1 1 1 1 1 4, 2 ⁄ ⁄ — 1 1 1 1 1 1 1 1 1 4, 2 — 12 20 1 1 12 20 1 6 UC4278-XL-21-LIS BLANK UG #14-#2 MAX NONE 4 3∅ 13 UC4279-XL-21-LIS BLANK UG #14-#2 MAX NONE 4 12 1 1 1∅ * These units are prewired per LIPA specifications. CONCENTRIC K.O.ʼS ⁄8 ⁄8 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 ⁄ ⁄ ACCESSORIES 13 INTERCHANGEABLE UNIT HUBS SMALL “RL" LARGE “R” OPENING (STANDARD) OPENING (HEAVY DUTY) SUFFIX SIZE -WL -YL -ZL -DL -EL 1″ 11⁄4″ 11⁄2″ 2″ 21⁄2″ MILBANK CAT. NO. SUFFIX SIZE A7514 A7515 A7516 A7517 A7518 3″ 31⁄2″ -F -G -H 4″ MILBANK CAT. NO. A8110 A8111 A8112 HUB SUFFIX CHART HUB ADAPTER PLATE (Converts -R opening to -RL) S8324 REMOVABLE HUB CLOSING PLATE DESCRIPTION SUFFIX CAT. # STANDARD (for -RL opening) -XL A7551 LARGE (for -R opening) -X A9064 SUFFIX WL YL ZL DL EL F G H HUB APPLICATION SIZE 1″ 11⁄4″ 11⁄2″ 2″ 21⁄2″ 3″ 31⁄2″ 4″ For -RL Opening For -RL Opening For -RL Opening For -RL Opening For -RL Opening For -R Opening For -R Opening For -R Opening TRIPLEX GROUND CLOSING COVERS DISCONNECT SLEEVE M5-144 METER CLOSING PLATE (Gray Plastic) 6003 METAL CLOSING PLATE (For ringless sockets) CP-21 K1190 (For factory installed triplex ground add suffix “TG” to the catalog number.) CONNECTOR KITS BYPASS LINK TWIN SINGLE K8180 (Bypass links are sold in pairs) SUFFIX CATALOG # (3 per set) – 1 ∅ SUFFIX CATALOG # (3 per set) – 1 ∅ K1 K3 K1539 K1540 350 MCM (MAX) 600 MCM (MAX) K2 K4 K1350 K1541 350 MCM (MAX) 600 MCM (MAX) SUFFIX CATALOG # (4 per set) – 3 ∅ SUFFIX CATALOG # (4 per set) – 3 ∅ K5 K7 K3082 K3441 350 MCM (MAX) 600 MCM (MAX) K6 K8 K3442 K3083 350 MCM (MAX) 600 MCM (MAX) 13 MISCELLANEOUS For use with 3/8”-16 stud type units only 14 AMPACITY INFORMATION CONDUCTOR SIZE AWG,MCM TYPE RHW & RHH (without outer covering) THW TW THW FEPB (6 thru 2), RHW and RHH (without outer covering) RH, THHW CONDUIT TRADE SIZES (INCHES) 1 ⁄4 1 11⁄4 11⁄2 2 21⁄2 3 ⁄2 31⁄2 3 4 14 12 10 8 6 4 4 1 10 8 6 3 16 13 11 5 29 24 19 10 40 32 26 13 65 53 43 22 93 76 61 32 143 192 117 157 95 127 163 85 49 66 6 1 2 3 7 10 16 23 36 48 62 3 1 1 2 4 6 10 15 23 31 40 1 1 1 1 1 1 1 2 1 1 1 3 3 2 1 5 5 4 3 8 7 6 5 12 10 9 7 16 14 12 10 21 18 15 13 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 4 3 3 2 1 6 5 4 4 3 8 7 6 5 4 10 9 8 7 6 1 1 1 1 1 1 1 1 1 3 2 2 4 3 3 5 4 4 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750 *This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C. * ALLOWABLE AMPACITIES OF INSULATED COPPER & ALUMINUM CONDUCTORS (3W IN CONDUIT)75°C(167°F) MISCELLANEOUS *CU AL or Cu-Clad AL A B A C 18 16 14 12 10 8 — — 20 25 35 50 — — — 12 10 8 — — — 20 30 40 6 4 3 2 1 65 85 100 115 130 6 4 3 2 1 50 65 75 90 100 1/0 2/0 3/0 4/0 150 175 200 230 1/0 2/0 3/0 4/0 120 135 155 180 250 300 350 400 500 255 285 310 335 380 250 300 350 400 500 205 230 250 270 310 600 700 750 420 460 475 600 700 750 340 375 385 AMPACITY CORRECTION FACTORS AMBIENT CORRECTION AMBIENT TEMP.C° FACTOR TEMP.F° 21 - 25 1.05 70 - 77 26 - 30 1.00 79 - 86 31 - 35 .94 88 - 95 36 - 40 .88 97 - 104 41 - 45 .82 106 - 113 46 - 50 .75 115 - 122 51 - 55 .67 124 - 131 56 - 60 .58 133 - 140 61 - 65 .33 142 - 158 (Per NEC table 310-16) 66 - 70 — 160 - 176 Overall ampere ratings of U/L listed Milbank multiple position meter sockets are based on 1993 N.E.C. Manual article 220-32 and ANSI / UL-414 (except where restricted by line connector size.) These requirements provide for a diversity factor / demand factor being utilized in determining the overall (main bus / lug) rating of a gang socket. All Milbank U/L listed gang sockets meet or exceed these diversity factor/demand factor requirements. Standard overall ampacity ratings for U/L listed and non U/L listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are based on the meter socket being wired with 75° C insulated wire conductor, sized in accordance with Table 310-16 of the National Electric Code. A = Size: AWG/MCM B = Ampere Rating for Insulation Types: FEPW, RH, RHW, THW, THWN, XHHW, USE, 2W. C = Ampere Rating for Insulation Types: RH, RHW, THW, THWN, XHHW, USE GANG SOCKET OVERALL AMPACITIES NO. OF METER POSITIONS 2 3 4 5 6 100A / POS. AMPACITY 200A 200A 200A 225A 270A 125A / POS. AMPACITY 200A 225A 250A 285A 330A 150A / POS. AMPACITY 200A 225A 270A 338A 396A 200A / POS. AMPACITY 200A 270A 360A 450A 528A Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk () shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG copper: or 15 amps for 12 AWG and 25 amps for 10 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. 14 ENERGIZATION OF ELECTRICAL EQUIPMENT 15 BEFORE ENERGIZING A. Give equipment a thorough visual examination to determine that: 1) No shipping or installation damage exists. 2) Proper clearances have been maintained. 3) All connections have been made. 4) Equipment is clean and dry. B. Make a thorough examination to verify: 1) Tightness of all bolted connections ( see table below.) 2) Manually operate all circuit breakers, switches, relays, etc. 3) Check rigidity of all mountings, bus bars and components. 4) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the off position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These steps will secure the installation in case of accidental energization. WHEN ENERGIZING A. Use caution and follow established safety procedures: 1) Wear safety apparel. 2) Use safety equipment. 3) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. AFTER ENERGIZING A. Secure the installation: 1) To prevent accidental contact with energized parts, cover all openings with approved filler devices. 2) To prevent unauthorized access, secure all covers and/or doors with approved security devices. 3) Attach/post information to advise others of potential hazards associated with the installation. RECOMMENDED TORQUE FOR GENERAL APPLICATIONS* JOINT DESCRIPTION SCREW NUT 10 10 10 12 12 1/4 1/4 5/16 5/16 3/8 1/2 BRASS STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL Brass Nut or Extruded Hole CU or AL Busbar <1/8″ Steel Nut or EH; CU or AL Busbar >1/8″ Aluminum Extruded Hole Steel Nut or Extruded Hole Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Steel Nut Steel Nut HEAD TYPE TORQUE ( INCH LBS. ) ALL ALL ALL ALL ALL ALL ALL HEX HEX HEX HEX 20-25 in. lbs. 25-30 in. lbs 30-35 in. lbs 30-35 in. lbs 40-50 in. lbs. 40-50 in. lbs. 50-60 in. lbs. 60-70 in. lbs. 100-150 in. lbs. 150-200 in. lbs. 200-250 in. lbs. *Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. EH: Extruded Hole CU: Copper AL: Aluminum 15 MISCELLANEOUS NOMINAL SIZE 16 COMMERCIAL ENCLOSURES “Ask your local Milbank Enclosure Distributor for the current Milbank Enclosure Catalog or find it on-line at www.milbankmfg.com” Type 1 Enclosures Wireway–Type 1 Screw Cover–SC1 Hinge Cover–HC1 Telephone Cabinet Covers–TSC Telephone Cabinet Flush Mount Covers–TFLC Screw Cover Wireway–GSC1 Hinged Cover Wireway–GHC1 Wireway–Type 3R Screw Cover Wireway Trough–GSC3R Type 3R Enclosures Screw Cover–SC3R Hinged Cover–HC3R Telephone Cabinet Hinged Cover–TC3R 2 Door Current Transformer Cabinet–CT3R Miscellaneous MISCELLANEOUS Accessories 16 COMMERCIAL PEDESTALS 17 COMMERCIAL METER PEDESTAL The commercial pedestal is a pad mounted, weatherproof meter pedestal which contains an underground utility pull section, a utility meter section, and a customer compartment with pull section. Typical uses are street and area lighting control, pump and irrigation control, remote power, and temporary power needs. It is designed to provide a vandal resistant enclosed meter socket and a customer section in a single enclosure. The three sections are isolated and can be padlocked and sealed for security. The customer section is designed to include distribution as well as control components. A deadfront is used to provide safety and protect interior parts. The pedestal is UL listed as an Enclosed Industrial Control, suitable only for use as service equipment (File Number E113855.) Most units comply with EUSERC drawing #308. MISCELLANEOUS 17 18 NOTES 18 NOTES 19 19 Meter Mounting Equipment & More! Commercial Electrical Enclosures Residential & Commercial Metering Disconnect Devices Current Transformer Enclosures RV/MH Pedestals Power Outlets Circuit Breakers Enclosed Circuit Breakers Safety Switches Test Switches KELLY & NOVIELLO ASSOCIATES 65 Mahan Street West Babylon, NY 11704 Tel: 631-643-1100 Fax: 631-643-1125 MILBANK MFG. CO. PO Box 419028 Kansas City, MO 64141-0028 Tel: 816.483.5314 Fax: 816.483.6357 www.milbankmfg.com www.milbankmfg.com LIPA 08/09 ( 1500 )
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23 Format : application/pdf Creator : Kim Tappan Title : Keyspan-LIPA 8-09:Layout 1 Modify Date : 2009:08:31 09:48:45-05:00 Creator Tool : QuarkXPress 7.2 Create Date : 2009:08:31 09:45:25-05:00 Metadata Date : 2009:08:31 09:48:45-05:00 Trapped : False GTS PDFX Version : PDF/X-1:2001 GTS PDFX Conformance : PDF/X-1a:2001 Producer : Acrobat Distiller 8.1.0 (Macintosh) Document ID : uuid:365d426e-14cf-4dee-b6cc-55ead2e2dae0 Instance ID : uuid:c5d614a2-8cac-4c87-afc1-71dd90d03515 Page Count : 20 Author : Kim TappanEXIF Metadata provided by EXIF.tools