Keyspan LIPA 8 09 685237 Catalog

648266-Catalog 648266-Catalog 648266-Catalog Batch9 unilog cesco-content

2014-09-05

: Pdf 685237-Catalog 685237-Catalog 784572 Batch7 unilog

Open the PDF directly: View PDF PDF.
Page Count: 20

DownloadKeyspan-LIPA 8-09  685237-Catalog
Open PDF In BrowserView PDF
Meter Mounting Equipment
LIPA
National Grid

2

MILBANK OVERVIEW

Charles A. Milbank
1879-1966

Bill Martin
1916-1998

Robert F. Waldrop
1922-2002

Robert F. Waldrop, II
Chairman

Katrina Waldrop Henke
Vice Chairman

Milbank–Quality Metering Products for 80 Years

M

ilbank Manufacturing
Company was established in 1927 by
Charles A. Milbank.
Originally, the company manufactured high voltage switches;
however, by 1941 Milbank devoted itself primarily to the manufacture of sheet metal enclosures
and related equipment for the
electrical generation and distribution industry. Today we are an
industry leader in the manufacture of electrical meter sockets.
Through a national network of
manufacturer’s representatives we
provide wholesale electrical distributors with quality electrical
products for the utility, contractor,
industrial and OEM markets.
As the meter standards have
changed, Milbank has been successful in adapting its product
line to these changes. Our full
scale engineering department
designs products to meet customer specifications and satisfy
all
utility
requirements.
Milbank’s employee base of over
1,000 workers, along with our
five manufacturing facilities com-

prising almost 550,000 square
feet give us the flexibility to
schedule, produce, and ship
orders quickly.
Currently,
Milbank manufactures over
10,000 different catalog items,
and this list continues to grow.
Our unique product offering
includes:
Residential
&
Commercial Meter Sockets;
Residential & Commercial Meter
Pedestals; RV/MH Power Outlets,
Service
Pedestals,
and
Transformers; Commercial &
Industrial Electrical Enclosures;
Circuit Breakers; Disconnects &
Safety Switches; Safety Sockets;
Utility & Residential Secondary
Pedestals; Hubs, and related
accessories. If you don’t find a
unit in this catalog to service your
needs, send us your specifications
and we will be happy to work
with you.
Our success has come from a
loyal customer base that can rely
on us to build quality products at
a fair price in a timely manner.
Our willingness and ability to
design and produce new products
to meet our customer demands is

2

an important factor to remain
competitive in today’s electrical
market.
Milbank has been serving the
electric utility & wholesale distribution industries for 80 years
with innovative, quality engineered products. So remember
us for all of your meter mounting
and related requirements, and
we will be happy to serve you as
we have in the past–with dependable service and quality products!
We take great pride in being
one of the few family-owned
businesses left in our industry.
We are a third generation run
business and truly believe that...

FAMILY MAKES A
DIFFERENCE!

TABLE OF CONTENTS

CATALOG NUMBER LOGIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
DISCONNECTS
30 & 60 amp – Fusible / Non-Fusible – Air Conditioner Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

AC Disconnect / Spa Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SINGLE POSITION

200 amp – Ringless – 5 & 7 Terminal – Lever Bypass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
320 amp Continuous – 400 amp Max – 5 Terminal – Jaw Clamping Lever – Ringless – 600 vac . . . . . . . . . . . . . .8
100-320 amp – 5 & 7 Terminal – Lever Bypass with Main Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
MULTIPLE POSITION

100 / 200 amp – 5 Terminal – Horizontal Gangs – Ringless–600 vac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
CONDOMINIUM METER MAIN
200 amp – 5 Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
TRANSFORMER RATED

400 / 800 amp – Trans-S Cabinets – Overhead / Underground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
MISCELLANEOUS
Milbank Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Ampacity Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

Energization of Electrical Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Other Milbank Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-17
INDEX

CAT.NO.
PG
6003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
A7514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
A7515 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
A7516 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
A7517 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
A7518 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
A7551 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
A8110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
A8111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
A8112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
A9064 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
CP-21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
K1190 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
K1350 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
K1539 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
K1540 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
K1541 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
K3082 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
K3083 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
K3441 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
K3442 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
K8180 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
M5-144 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
S8324 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
U1854-XL-QG-BLG-LIS . . . . . . . . . . . . . . . . . . . . . . . .7
U3042-XL-QG-BLG-LIS . . . . . . . . . . . . . . . . . . . . . . . .7
U3800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
U3801 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3

CAT.NO.
PG
U3830 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
U3860 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
U3822-20GR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
U3986-XL-100-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . .11
U3986-XL-150-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . .11
U3986-XL-200-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . .11
U4142-XT-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
U4143-XT-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
U4144-XT-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
U4154-XT-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
U4163-XT-11-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
U4165-XT-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
U4166-XT-Z21-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . .12
U4302-X-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
U4303-X-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
U4304-X-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
U4305-X-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
U4306-X-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
U4523-X-Z11-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
U4554-X-Z21-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
U4881-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
U4881-O-50GB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
U4881-O-60GB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
U5059-X-2/150-K3L-LIS . . . . . . . . . . . . . . . . . . . . . . .11
U5080-RXL-200-LIS . . . . . . . . . . . . . . . . . . . . . . . . . .11
U5703-X-K3L-K2L-LIS . . . . . . . . . . . . . . . . . . . . . . . . .8
UC4278-XL-21-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . .12
UC4279-XL-21-LIS . . . . . . . . . . . . . . . . . . . . . . . . . . .12

3

4

CATALOG NUMBER LOGIC

4

30 & 60 AMP–FUSIBLE / NON-FUSIBLE–AIR CONDITIONER DISCONNECTS

5

DISCONNECTS

U3801

U3800

U3860

(No deadfront required)

PROFILE
Milbankʼs air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our
compact design meets all wire bending space requirements in the NEC and, also, complies with article
440-14 in the NEC. To insure the safest conditions, we designed our disconnect pullers to be removable or they may be reinstalled in the off position. Another safety feature is the padlock provision on the
front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel and
finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy
and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This
offers a durable, nonfading finish.

TECHNICAL INFORMATION
AMP

TYPE

CATALOG
NUMBER

MAX WT.
H.P. @
#

30

FUSIBLE

U3830

3

2.7

60

FUSIBLE

U3860

10

3.3

60 NONFUSIBLE

U3800

10

3.25

60 NONFUSIBLE

U3801

10

2.5

LINE & LOAD
WIRE RANGE

GROUND
WIRE RANGE

DIMENSIONS

WIRE RATING
CU °C

CU

AL

CU/AL

D"

W"

H"

#14-#3
AWG
#14-#3
AWG
#14-#2
AWG
#14-#3
AWG

#14-#3
AWG
#14-#3
AWG
#12-#2
AWG
#14-#3
AWG

#14-3 AWG

2-5/8

5

7

#14-3 AWG

3

5

#14-3 AWG

3

5

#14-3 AWG

2-3/8

5

AL °C

60°/75° 60°/75°

91⁄4 60°/75° 60°/75°
8

60°/75° 60°/75°

6-3/4 60°/75° 60°/75°



U/L listed as Enclosed Pullout Switch



Type 3R Rainproof



1∅, 240 VAC



Six one-inch concentric knockouts

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

5

AC DISCONNECT / SPA BOX

Combination AC Disconnect / 20 Amp GFCI Receptacle–Together in 1 Box

DISCONNECTS

6

• Meets NEC # 210.63 Requirements *
• UL Listed as Power Outlet
• Type 3R Enclosure
• In-Use Cover**
• Duplex Ground Connector
• 1” Concentric Knockouts
* NEC® #210.63 Heating, Air-

60 amp,
Non-Fused
AC Disconnect

Type 3R
Enclosure with
In-Use Cover

GFCI RECEPTACLE
• 20 amp
• Reset/Test Button
• Padlock provision

U3822-20GR

AMP
60

TYPE

CATALOG MAX WT.
NUMBER H.P. @
#

NONFUSIBLE U3822-20GR

10

LINE & LOAD CONNECTOR
WIRE RANGE

6

Conditioning and Refrigeration
Equipment Outlet.
...The receptacle shall be located on the same level and within
7.5 m (25 ft.) of the heating, airconditioning and refrigeration
equipment.
* NEC® #210.08 Ground-Fault
Circuit– Interruptor protection
for personnel.

AC DISCONNECT
• 1∅, 240 Volt
• 60 amp, Non-Fused

Duplex 20 amp
GFCI Receptacle

GROUND CONNECTOR
WIRE RANGE

CU

AL

CU/AL

#14-#2
AWG

#12-#2
AWG

#14-4 AWG

DIMENSIONS

WIRE RATING

D″

CU °C

W″

H″

AL °C

4.8 5.25 7.4 60°/75° 60°/75°

To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position.
All units are designed with a padlock provision on the cover for security.
**Note: U3822-20GR cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle).
*Reprinted with permission from NFPA 70-2002, National Electrical Code®, Copyright 2001, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete
and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code® and NEC® are registered trademarks of the
National Fire Protection Association, Quincy, MA.

Hot Tub Disconnect or Sub Panel Breaker Enclosure–Type 3R
Spa Box with GFCI Protection
•
•
•
•
•
•
•
•
•
•
•

240 volt ground fault protection
UL listed, Type 3R rainproof
Milbank reliability
Easy installation
2 pole, 50 or 60 amp GFCI breaker protection
Compact size:
8-1/2” H x 7-1/2” W x 3-3/4” D
3 or 4 wire installation
1∅, 120 / 240 VAC
Standard package of 12
2 extra one-pole breaker spaces
100 amp overall rating

Sub Panel Breaker Enclosure
• Use as a 100 amp, 4 circuit sub panel
enclosure
• U4881-O has provision for (2) 2-pole or
(4) 1-pole small frame breakers

U4881-O-50GB

AMP TYPE

CATALOG
NUMBER

WT.
@
#

U4881-O

LINE & LOAD CONNECTOR
WIRE RANGE

Utility requirements for this equipment may vary. Always consult the
serving utility for their requirements
before ordering or installing equipment in this catalog.

GROUND CONNECTOR
WIRE RANGE

DIMENSIONS

CU

AL

CU/AL

D″

W″

H″

7

#14-1/0

#14-1/0

#14-1/0

3 3⁄4

71⁄2

81⁄2

50 BREAKER U4881-O-50GB

8

#14-1/0

#14-1/0

#14-1/0

3 3⁄4

71⁄2

81⁄2

60 BREAKER U4881-O-60GB

8

#14-1/0

#14-1/0

#14-1/0

3 3⁄4

71⁄2

81⁄2

–

BREAKER
PROVISION

6

200 AMP – RINGLESS – 5 & 7 TERMINAL – LEVER BYPASS

4

2

3
55

SINGLE POSITION

1

4
6

U3042-XL-QG-BLG-LIS

U1854-XL-QG-BLG-LIS

200 AMP–5 TERMINAL–RINGLESS–1∅3W
CONNECTORS
AMP SERVICE
200

OH/UG

CATALOG
NUMBER

HUB

BY- DIMENSIONS
LOAD PASS D″ W″ H″

CONCENTRIC K.O.ʼS

CU/AL

LINE

U3042-XL-QG-BLG-LIS C.P. #6-350
kcmil

#6-350 LEVER
4
kcmil

7

⁄8

13

19

1

2

3

1

3

⁄2

2

3

4

5

3

1

⁄4

6
1 1
4, 2

⁄ ⁄

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Lever on the U3042 supplies clamping action on meter spades and also operates bypass device.
INSULATED NEUTRAL: For field installed insulated neutral order as extra catalog number K1047.
BARREL LOCK (-BLG): Has provision for barrel lock with guard.

200 AMP–7 TERMINAL–RINGLESS–3∅4W
CONNECTORS
AMP SERVICE
200

OH/UG

CATALOG
NUMBER

HUB

BY- DIMENSIONS
LOAD PASS D″ W″ H″

CONCENTRIC K.O.ʼS

CU/AL

LINE

U1854-XL-QG-BLG-LIS C.P. #6-350
kcmil

#6-350 LEVER
4
kcmil

7

⁄8

13

19

1

2

3

1

2

⁄2

3
3

4

5

3

1

⁄4

6
1 1
4, 2

⁄ ⁄

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
INSULATED NEUTRAL: For field installed insulated neutral order as extra catalog number K1047.
BARREL LOCK (-BLG): Has provision for barrel lock with guard.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

7

7

320 AMP CONTINUOUS–400 AMP MAX–5 TERMINAL
JAW CLAMPING LEVER–RINGLESS–600 VAC

SINGLE POSITION

8

5073

U5073-X-K3L-K2L-LIS

320 AMP–5 TERMINAL–RINGLESS–1∅3W–600 VAC
CONNECTORS
SERVICE
OH/UG

CATALOG
NUMBER
U5073-X-K3L-K2L-LIS*

HUB

LINE
C.P.

BY- DIMENSIONS
PASS
LOAD
D″ W″ H″

CONCENTRIC K.O.ʼS

CU/AL

#4-600 or (2)
1/0 -250

(twin)
350

LEVER

7

4

⁄8

15

31

1

⁄2

1
3

2
3

3
3

4

5

3

1

⁄4

6
1 1
4, 2

⁄ ⁄

BYPASS: The lever supplies the clamping action and also operates bypass device.
CONNECTORS: Factory installed connectors - line side - single conductor #4-600 kcmil or 2 conductors 1/0 - 250 kcmil load side - twin connectors #6-350 kcmil
* UL LISTED based on parallel 250 kcmil connectors maximum.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

8

100/200 AMP–5 TERMINAL–HORIZONTAL GANGS–RINGLESS–600 VAC

2

1

1

MULTIPLE POSITION

U4142
3

4

3

5

4

U4142-XT-LIS

100 / 200 AMP PER POSITION–5 TERMINAL–RESIDENTIAL / COMMERCIAL
AMP

CATALOG
NUMBER

100/200 U4142-XT-LIS

NO.
OF HUB SERVICE
POS.
2

C.P. OH/UG

100/200 U4143-XT-LIS

3

C.P. OH/UG

100/200 U4144-XT-LIS

4

C.P. OH/UG

CONNECTORS
CU/AL

LINE

LOAD

3/8 x 16″
STUDS
3/8 x 16″
STUDS
3/8 x 16″
STUDS

#6-350
kcmil
#6-350
kcmil
#6-350
kcmil

DIMENSIONS

BYPASS

D″

LEVER

6

32

LEVER

6

42

3

LEVER

6

52

W″

H″

1

⁄8 251⁄4
1

CONCENTRIC K.O.ʼS
1
1

2

2

3

1

4

2

1

2

1

2

⁄16 25 ⁄4

2

1

2

⁄4 251⁄4

⁄2
⁄2
⁄2

⁄2

4

5

6

1

1 1
4, 2

⁄ ⁄

–

1

1 1
4, 2

⁄ ⁄

–

1

1 1
4, 2

–

2

1

4

2

1

4

2

⁄2
⁄2

⁄2
⁄2
⁄2

⁄ ⁄

HUBS: Units are supplied with two closing plates as standard. To order hubs as extra refer to the hub chart on the accessory
page.
LEVER BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
CONNECTORS: Line wire sections are supplied with 3/8″ – 16 hex head nuts with Belleville washers. For single lug connector
kits, order as extra: K1539 (350 kcmil) or K1540 (600 kcmil). For twin lug connectors: K1350 (350 kcmil) or K1541 (600 kcmil).

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

9

9

10

200 AMP–5 TERMINAL–CONDOMINIUM METER MAIN

1

2 2

2

2 2

2 3

1

2 POSITION

2 2

2

2 2

2 3

3 POSITION

U4304-X-LIS

METER MAIN

3 2

2 2

1

1

2 2

2 3

4-6 POSITION

200 AMP–5 TERMINAL–RINGLESS–LEVER BYPASS–CONDO METER MAIN–1Ø3W
CATALOG
NUMBER

CONNECTORS
BYPASS

HUB

LINE

DIMENSIONS

LOAD

D”

W”
3

CONCENTRIC K.O.ʼS
H”

1

2

3
1 1
4, 2

U4302-X-LIS*

LEVER

C.P.

3/8”-16 STUD

BREAKER

6

27

⁄4

48

4

2

U4303-X-LIS

LEVER

C.P.

3/8”-16 STUD

BREAKER

6

27 3⁄4

60

4

2

U4304-X-LIS

LEVER

C.P.

3/8”-16 STUD

BREAKER

6

45

48

4

2

U4305-X-LIS

LEVER

C.P.

3/8”-16 STUD

BREAKER

6

45

60

4

2

U4306-X-LIS

LEVER

C.P.

3/8”-16 STUD

BREAKER

6

45

60

4

2

⁄ ⁄
1 1
⁄4, ⁄2
1 1
⁄4, ⁄2
1 1
⁄4, ⁄2
1 1
⁄4, ⁄2

HUBS: Units are supplied with 2 closing plates as standard. To order hubs as extra refer to the hub chart on the accessory
page.
CONNECTORS: Line wire sections are supplied with 3/8″ - 16 hex head nuts with Belleville washers. For single lug connector kits, order as extra: K1539 (350 kcmil) or K1540 (600 kcmil). For twin lug connectors: K1350 (350 kcmil) or K1541 (600
kcmil.)
LEVER BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
REPLACEMENT LOCKING PIN: For replacement locking pin order part number Z816559-SC (1 pin).
BREAKERS: Units have provision for (1) double pole main per meter position. Breakers NOT included – order as extra.
See chart below.
* 2 Position Condominium meter main has additional 3” knockout (bottom left section).

PLUG-IN BREAKER COMPATIBILITY CHART
CUTLER-HAMMER

AMPS MILBANK (WESTINGHOUSE
/ BRYANT)

125-200
≤ 100

SIEMENS
SIEMENS
MURRAY /
(ITE)
CROUSE-HINDS

G.E.

SQ-D
—

Q

BR / BJ / HQP

—

MD

Q LINE

Q

QUICKLAG P /
BR / HQP

QP

MP

Q LINE HOMELINE

10

Utility requirements for this equipment may vary. Always consult
the serving utility for their requirements before ordering or installing
equipment in this catalog.

100-320 AMP—5 & 7 TERMINAL—LEVER BYPASS WITH MAIN BREAKER

4

2

1

5

3

SINGLE POSITION

1

6

4

3986
5080

5059

U5059-X-2/150-K3L-LIS

U3986-XL-200-LIS

100 / 150 / 200 / 320 AMP—5 & 7 TERMINAL—WITH MAIN BREAKER—RINGLESS—LEVER BYPASS
NO.
OF AMP
TERM.
5
5
5
7
7
5

CONNECTORS

CATALOG
NUMBER

HUB SERVICE

100 U3986-XL-100-LIS C.P. OH/UG
150 U3986-XL-150-LIS C.P. OH/UG
200 U3986-XL-200-LIS C.P. OH/UG
150 U5080-RXL-150-LIS C.P. OH/UG
200 U5080-RXL-200-LIS C.P. OH/UG
320

U5059-X-2/150-K3L-LIS*

C.P.

UG

CU/AL

LINE

LOAD

#6-350
kcmil
#6-350
kcmil
#6-350
kcmil
#6-350
kcmil
#6-350
kcmil
#4600
kcmil

#1-300
kcmil
#1-300
kcmil
#1-300
kcmil
#1-300
kcmil
#1-300
kcmil
#1/0-300
kcmil

BYPASS

DIMENSIONS
D″
7

LEVER 4

⁄8

7

LEVER 4

⁄8

7

LEVER 4

⁄8

7

LEVER 4

⁄8

W″
13
13
13
13

H″

1

2

34

1

1
1

34
34
34

7

13

34

7

15

42

LEVER 4
LEVER 4

⁄8
⁄8

CONCENTRIC K.O.ʼS

2

⁄2

1

2

⁄2

1

2

⁄2

1

2

⁄2

1

2

⁄2

3

2
2

⁄2
⁄2

3

4

5

3

3

1

1 1
4, 2

3

3

1

1 1
4, 2
1 1
4, 2

⁄4
⁄4

6

⁄ ⁄
⁄ ⁄

1

3

3

1

1

3

3

1

1 1
4, 2

1

⁄4

1 1
4, 2

1 1
4, 2

---

2
2

⁄2
⁄2

1

3

3

3

3

1

2

⁄2

⁄4

⁄4
⁄4

⁄ ⁄
⁄ ⁄

⁄ ⁄

⁄ ⁄

HUBS: Unit is supplied with closing plates as standard. To order hubs as extra, refer to the hub chart on the accessory page.
LEVER BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
CONNECTORS: Line wire sections are supplied with #6-350 kcmil lay-in connectors.
BREAKER: U3986 has factory installed double pole Milbank UQFB-100-X1, UQFB-150-X1 or UQFB-200-X1 main breaker.
U5080 has factory installed 3 pole Milbank UQFB-3200 main breaker.
* Side Wireway

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

11

11

12

400 / 800 AMP–TRANS-S CABINETS–OVERHEAD / UNDERGROUND

2

2

5

4

3

3

4154
4165

4

4163
4166

5

4

3

3

4

2

U4154-XT-LIS

U4163-XT-11-LIS

1

5

4554
4523

5

4

3

4

4

3

Utility requirements for this equipment may vary. Always consult the
serving utility for their requirements
before ordering or installing equipment in this catalog.

2

4278
4279

4
5

200 / 400 / 800 AMP—METERED—TRANS-S CABINET–1∅3W OR 3∅3W–600 VAC
CONNECTORS

TRANSFORMER RATED

PHASE TERM

CATALOG
NUMBER

BY- DIMENSIONS
LINE LOAD PASS D″ W″ H″

CONCENTRIC K.O.ʼS

CU/AL

AMP

HUB SERVICE

1∅

6

U4554-X-Z21-LIS C.P. OH/UG 200/400

1∅

6

U4166-XT-Z21-LIS C.P. OH/UG 400/800

3∅

13

U4523-X-Z11-LIS C.P. OH/UG 200/400

3∅

13

U4163-XT-11-LIS C.P. OH/UG 400/800

SEE
NOTE*
#4-600
kcmil
SEE
NOTE*
#4-600
kcmil

#4-600
kcmil
#4-600
kcmil
#4-600
kcmil
#4-600
kcmil

1

2*

3

4

5

6

4

4

1

1

—

4

4

1

1

—

1

—

1

—

NONE

10

21

41

—

3

NONE

10

26

51

—

3

4

4

1

4

4

1

⁄8
⁄8

NONE

10

21

41

—

3

NONE

10

26

51

—

3

⁄8
⁄8

⁄4
⁄4
⁄4
⁄4

* This is a 3/8” hole with plastic plug, not a concentric knock-out.
Lugs provided – rated up to single 600 kcmil - #4 awg.
Short circuit current withstand capability is 50K symmetrical amps.
Furnished with 1/2” - 13 studs, washers and hex nuts with conical sems for CT mounting.
*Only 200/400 amp units have elliptical lug - 1-#4-600 kcmil or up to 2-1/0-250 kcmil.

400 / 800 AMP—UNMETERED ENCLOSURE
CONNECTORS

CATALOG
NUMBER

HUB SERVICE

U4165-XT-LIS

C.P. OH/UG

PHASE
1∅
3∅

U4154-XT-LIS

C.P. OH/UG

CU/AL

LINE

LOAD

#4-600
kcmil
#4-600
kcmil

#4-600
kcmil
#4-600
kcmil

DIMENSIONS

CONCENTRIC K.O.ʼS

BYPASS

D″

W″

H″

1

NONE

10

26

51

NONE

10

26

51

2*

3

4

—

3

4

4

—

3

⁄8
⁄8

4

5

6

1

—

1

—

1

4

1

⁄4
⁄4

* This is a 3/8” hole with plastic plug, not a concentric knock-out.
Lugs provided – rated up to single 600 kcmil - #4 awg.

20 AMP—1 PIECE COVER—REMOTE SOCKETS—RINGLESS—1∅—3∅ ∗
PHASE TERM

CATALOG
NUMBER

HUB SERVICE

CONNECTORS BY- DIMENSIONS
PASS D″ W″ H″
CU/AL

2

3

4

5

6

1

1

1

1

1

1

1

1 1
4, 2

⁄ ⁄

—

1

1

1

1

1

1

1

1 1
4, 2

—

12

20

1

1

12

20

1

6

UC4278-XL-21-LIS

BLANK

UG

#14-#2 MAX

NONE

4

3∅

13

UC4279-XL-21-LIS

BLANK

UG

#14-#2 MAX

NONE

4

12

1

1

1∅

* These units are prewired per LIPA specifications.

CONCENTRIC K.O.ʼS

⁄8
⁄8

⁄4
⁄4

⁄4
⁄4

⁄4
⁄4

⁄4
⁄4

⁄ ⁄

ACCESSORIES

13

INTERCHANGEABLE UNIT HUBS
SMALL “RL"
LARGE “R”
OPENING (STANDARD) OPENING (HEAVY DUTY)
SUFFIX SIZE

-WL
-YL
-ZL
-DL
-EL

1″
11⁄4″
11⁄2″

2″
21⁄2″

MILBANK
CAT. NO.

SUFFIX SIZE

A7514
A7515
A7516
A7517
A7518

3″
31⁄2″

-F
-G
-H

4″

MILBANK
CAT. NO.

A8110
A8111
A8112

HUB SUFFIX CHART
HUB ADAPTER PLATE
(Converts -R opening to -RL)
S8324

REMOVABLE HUB CLOSING PLATE
DESCRIPTION SUFFIX

CAT. #

STANDARD
(for -RL opening)

-XL

A7551

LARGE
(for -R opening)

-X

A9064

SUFFIX
WL
YL
ZL
DL
EL
F
G
H

HUB APPLICATION
SIZE
1″
11⁄4″
11⁄2″
2″
21⁄2″
3″
31⁄2″
4″

For -RL Opening
For -RL Opening
For -RL Opening
For -RL Opening
For -RL Opening
For -R Opening
For -R Opening
For -R Opening

TRIPLEX GROUND
CLOSING COVERS
DISCONNECT
SLEEVE
M5-144

METER CLOSING PLATE
(Gray Plastic)
6003

METAL CLOSING PLATE
(For ringless sockets)
CP-21

K1190
(For factory installed triplex
ground add suffix “TG” to
the catalog number.)

CONNECTOR KITS
BYPASS LINK

TWIN

SINGLE

K8180
(Bypass links are sold in pairs)

SUFFIX

CATALOG #

(3 per set) – 1 ∅

SUFFIX

CATALOG #

(3 per set) – 1 ∅

K1
K3

K1539
K1540

350 MCM (MAX)
600 MCM (MAX)

K2
K4

K1350
K1541

350 MCM (MAX)
600 MCM (MAX)

SUFFIX

CATALOG #

(4 per set) – 3 ∅

SUFFIX

CATALOG #

(4 per set) – 3 ∅

K5
K7

K3082
K3441

350 MCM (MAX)
600 MCM (MAX)

K6
K8

K3442
K3083

350 MCM (MAX)
600 MCM (MAX)

13

MISCELLANEOUS

For use with 3/8”-16 stud type
units only

14

AMPACITY INFORMATION

CONDUCTOR
SIZE
AWG,MCM

TYPE

RHW & RHH
(without outer covering)
THW

TW
THW
FEPB (6 thru 2),
RHW and
RHH
(without outer covering)
RH, THHW

CONDUIT TRADE SIZES (INCHES)
1

⁄4

1

11⁄4

11⁄2

2

21⁄2

3

⁄2

31⁄2

3

4

14
12
10
8

6
4
4
1

10
8
6
3

16
13
11
5

29
24
19
10

40
32
26
13

65
53
43
22

93
76
61
32

143 192
117 157
95 127 163
85
49
66

6

1

2

3

7

10

16

23

36

48

62

3

1

1

2

4

6

10

15

23

31

40

1
1
1

1
1
1
1

2
1
1
1

3
3
2
1

5
5
4
3

8
7
6
5

12
10
9
7

16
14
12
10

21
18
15
13

1
1

1
1
1
1
1

1
1
1
1
1

2
2
1
1
1

4
3
3
2
1

6
5
4
4
3

8
7
6
5
4

10
9
8
7
6

1
1
1

1
1
1

1
1
1

3
2
2

4
3
3

5
4
4

1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750

*This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C.
* ALLOWABLE AMPACITIES OF INSULATED COPPER &
ALUMINUM CONDUCTORS (3W IN CONDUIT)75°C(167°F)

MISCELLANEOUS

*CU

AL or Cu-Clad AL

A

B

A

C

18
16
14
12
10
8

—
—
20
25
35
50

—
—
—
12
10
8

—
—
—
20
30
40

6
4
3
2
1

65
85
100
115
130

6
4
3
2
1

50
65
75
90
100

1/0
2/0
3/0
4/0

150
175
200
230

1/0
2/0
3/0
4/0

120
135
155
180

250
300
350
400
500

255
285
310
335
380

250
300
350
400
500

205
230
250
270
310

600
700
750

420
460
475

600
700
750

340
375
385

AMPACITY CORRECTION FACTORS

AMBIENT
CORRECTION
AMBIENT
TEMP.C°
FACTOR
TEMP.F°
21 - 25
1.05
70 - 77
26 - 30
1.00
79 - 86
31 - 35
.94
88 - 95
36 - 40
.88
97 - 104
41 - 45
.82
106 - 113
46 - 50
.75
115 - 122
51 - 55
.67
124 - 131
56 - 60
.58
133 - 140
61 - 65
.33
142 - 158
(Per NEC table 310-16)
66 - 70
—
160 - 176
Overall ampere ratings of U/L listed Milbank multiple position meter sockets are based on
1993 N.E.C. Manual article 220-32 and ANSI / UL-414 (except where restricted by line connector size.) These requirements provide for a diversity factor / demand factor being utilized
in determining the overall (main bus / lug) rating of a gang socket. All Milbank U/L listed
gang sockets meet or exceed these diversity factor/demand factor requirements. Standard
overall ampacity ratings for U/L listed and non U/L listed gang sockets are as shown in the
chart below. Ampere ratings of meter sockets are based on the meter socket being wired
with 75° C insulated wire conductor, sized in accordance with Table 310-16 of the National
Electric Code.
A = Size: AWG/MCM
B = Ampere Rating for
Insulation Types:
FEPW, RH, RHW,
THW, THWN, XHHW,
USE, 2W.
C = Ampere Rating for
Insulation Types:
RH, RHW, THW,
THWN, XHHW, USE

GANG SOCKET OVERALL AMPACITIES
NO. OF METER
POSITIONS
2
3
4
5
6

100A / POS.
AMPACITY
200A
200A
200A
225A
270A

125A / POS.
AMPACITY
200A
225A
250A
285A
330A

150A / POS.
AMPACITY
200A
225A
270A
338A
396A

200A / POS.
AMPACITY
200A
270A
360A
450A
528A

 Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk ()
shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG copper: or 15 amps for 12 AWG and 25
amps for 10 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied.

14

ENERGIZATION OF ELECTRICAL EQUIPMENT

15

BEFORE ENERGIZING
A. Give equipment a thorough visual examination to determine that:
1) No shipping or installation damage exists.
2) Proper clearances have been maintained.
3) All connections have been made.
4) Equipment is clean and dry.
B. Make a thorough examination to verify:
1) Tightness of all bolted connections ( see table below.)
2) Manually operate all circuit breakers, switches, relays, etc.
3) Check rigidity of all mountings, bus bars and components.
4) Use test equipment to check continuity of circuitry and integrity of insulation.
C. All switches and circuit breakers should be in the off position.
D. Verify that manual meter bypass (if applicable) is in non-bypass position.
E. Install cover and/or close doors.
F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These
steps will secure the installation in case of accidental energization.

WHEN ENERGIZING
A. Use caution and follow established safety procedures:
1) Wear safety apparel.
2) Use safety equipment.
3) Take action to prevent injury to yourself and others in the event of failure of the installation.
4) Take action to prevent/decrease damage to property in the event of failure of the installation.
5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it.

AFTER ENERGIZING
A. Secure the installation:
1) To prevent accidental contact with energized parts, cover all openings with approved filler devices.
2) To prevent unauthorized access, secure all covers and/or doors with approved security devices.
3) Attach/post information to advise others of potential hazards associated with the installation.

RECOMMENDED TORQUE FOR GENERAL APPLICATIONS*
JOINT DESCRIPTION
SCREW

NUT

10
10
10
12
12
1/4
1/4
5/16
5/16
3/8
1/2

BRASS
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL

Brass Nut or Extruded Hole
CU or AL Busbar <1/8″
Steel Nut or EH; CU or AL Busbar >1/8″

Aluminum Extruded Hole
Steel Nut or Extruded Hole
Aluminum Extruded Hole
Steel Nut or EH; CU or AL Busbar
Aluminum Extruded Hole
Steel Nut or EH; CU or AL Busbar
Steel Nut
Steel Nut

HEAD TYPE

TORQUE
( INCH LBS. )

ALL
ALL
ALL
ALL
ALL
ALL
ALL
HEX
HEX
HEX
HEX

20-25 in. lbs.
25-30 in. lbs
30-35 in. lbs
30-35 in. lbs
40-50 in. lbs.
40-50 in. lbs.
50-60 in. lbs.
60-70 in. lbs.
100-150 in. lbs.
150-200 in. lbs.
200-250 in. lbs.

*Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first.
EH: Extruded Hole
CU: Copper
AL: Aluminum

15

MISCELLANEOUS

NOMINAL
SIZE

16

COMMERCIAL ENCLOSURES

“Ask your local Milbank Enclosure Distributor
for the current Milbank Enclosure Catalog or
find it on-line at www.milbankmfg.com”

Type 1 Enclosures

Wireway–Type 1

Screw Cover–SC1
Hinge Cover–HC1
Telephone Cabinet Covers–TSC
Telephone Cabinet Flush Mount Covers–TFLC

Screw Cover Wireway–GSC1
Hinged Cover Wireway–GHC1

Wireway–Type 3R
Screw Cover Wireway Trough–GSC3R

Type 3R Enclosures
Screw Cover–SC3R
Hinged Cover–HC3R
Telephone Cabinet Hinged Cover–TC3R
2 Door Current Transformer Cabinet–CT3R

Miscellaneous

MISCELLANEOUS

Accessories

16

COMMERCIAL PEDESTALS

17

COMMERCIAL METER PEDESTAL
The commercial pedestal is a pad mounted,
weatherproof meter pedestal which contains an
underground utility pull section, a utility meter section, and a customer compartment with pull section.
Typical uses are street and area lighting control, pump and irrigation control, remote power, and
temporary power needs.
It is designed to provide a vandal resistant
enclosed meter socket and a customer section in a
single enclosure. The three sections are isolated and
can be padlocked and sealed for security. The customer section is designed to include distribution as
well as control components. A deadfront is used to
provide safety and protect interior parts.
The pedestal is UL listed as an Enclosed
Industrial Control, suitable only for use as service
equipment (File Number E113855.) Most units comply with EUSERC drawing #308.

MISCELLANEOUS

17

18

NOTES

18

NOTES

19

19

Meter Mounting Equipment & More!
Commercial Electrical Enclosures
Residential & Commercial Metering
Disconnect Devices
Current Transformer Enclosures
RV/MH Pedestals
Power Outlets
Circuit Breakers
Enclosed Circuit Breakers
Safety Switches
Test Switches

KELLY & NOVIELLO ASSOCIATES
65 Mahan Street
West Babylon, NY 11704
Tel: 631-643-1100
Fax: 631-643-1125

MILBANK MFG. CO.
PO Box 419028
Kansas City, MO 64141-0028
Tel: 816.483.5314 Fax: 816.483.6357
www.milbankmfg.com

www.milbankmfg.com

LIPA 08/09 ( 1500 )



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23
Format                          : application/pdf
Creator                         : Kim Tappan
Title                           : Keyspan-LIPA 8-09:Layout 1
Modify Date                     : 2009:08:31 09:48:45-05:00
Creator Tool                    : QuarkXPress 7.2
Create Date                     : 2009:08:31 09:45:25-05:00
Metadata Date                   : 2009:08:31 09:48:45-05:00
Trapped                         : False
GTS PDFX Version                : PDF/X-1:2001
GTS PDFX Conformance            : PDF/X-1a:2001
Producer                        : Acrobat Distiller 8.1.0 (Macintosh)
Document ID                     : uuid:365d426e-14cf-4dee-b6cc-55ead2e2dae0
Instance ID                     : uuid:c5d614a2-8cac-4c87-afc1-71dd90d03515
Page Count                      : 20
Author                          : Kim Tappan
EXIF Metadata provided by EXIF.tools

Navigation menu