6ES72141AG400XB0
2016-01-18
: Pdf 6Es72141Ag400Xb0 6ES72141AG400XB0 Siemen DataSheet
Open the PDF directly: View PDF .
Page Count: 1
Download | ![]() |
Open PDF In Browser | View PDF |
Data sheet 6ES7214-1AG40-0XB0 SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0 - 10V DC, POWER SUPPLY: DC 20.4 - 28.8 V DC, PROGRAM/DATA MEMORY: 100 KB General information Product type designation CPU 1214C DC/DC/DC Firmware version V4.1 Engineering with ● Programming package STEP 7 V13 SP1 or higher Display with display No Supply voltage Rated value (DC) ● 24 V DC Yes permissible range, lower limit (DC) 20.4 V permissible range, upper limit (DC) 28.8 V Reverse polarity protection Yes Load voltage L+ ● Rated value (DC) 24 V ● permissible range, lower limit (DC) 20.4 V ● permissible range, upper limit (DC) 28.8 V 6ES7214-1AG40-0XB0 Page 1/8 18.01.2016 Changes preserved © Copyright Siemens AG Input current Current consumption (rated value) 500 mA; CPU only Current consumption, max. 1 500 mA; CPU with all expansion modules Inrush current, max. 12 A; at 28.8 V Encoder supply 24 V encoder supply ● 24 V L+ minus 4 V DC min. Output current for backplane bus (5 V DC), max. 1 600 mA; Max. 5 V DC for SM and CM Power loss Power loss, typ. 12 W Memory Type of memory RAM Work memory ● integrated 100 kbyte ● expandable No Load memory ● integrated 4 Mbyte ● Plug-in (SIMATIC Memory Card), max. with SIMATIC memory card Backup ● present Yes; maintenance-free ● without battery Yes CPU processing times for bit operations, typ. 0.085 µs; / instruction for word operations, typ. 1.7 µs; / instruction for floating point arithmetic, typ. 2.3 µs; / instruction CPU-blocks Number of blocks (total) DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used OB ● Number, max. Limited only by RAM for code Data areas and their retentivity retentive data area in total (incl. times, counters, flags), max. 10 kbyte Flag ● Number, max. 8 kbyte; Size of bit memory address area Local data ● per priority class, max. 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB 6ES7214-1AG40-0XB0 Page 2/8 18.01.2016 Changes preserved © Copyright Siemens AG Address area Process image ● Inputs, adjustable 1 kbyte ● Outputs, adjustable 1 kbyte Hardware configuration Number of modules per system, max. 3 comm. modules, 1 signal board, 8 signal modules Time of day Clock ● Hardware clock (real-time clock) Yes ● Backup time 480 h; Typical ● Deviation per day, max. 60 s/month at 25 °C Digital inputs Number of digital inputs ● of which inputs usable for technological functions 14; Integrated 6; HSC (High Speed Counting) integrated channels (DI) 14 m/p-reading Yes Number of simultaneously controllable inputs all mounting positions — up to 40 °C, max. 14 Input voltage ● Rated value (DC) 24 V ● for signal "0" 5 V DC at 1 mA ● for signal "1" 15 VDC at 2.5 mA Input delay (for rated value of input voltage) for standard inputs — parameterizable 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four — at "0" to "1", min. 0.2 ms — at "0" to "1", max. 12.8 ms for interrupt inputs — parameterizable Yes for counter/technological functions — parameterizable Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz Cable length ● shielded, max. 500 m; 50 m for technological functions ● unshielded, max. 300 m; For technological functions: No Digital outputs Number of digital outputs ● of which high-speed outputs 6ES7214-1AG40-0XB0 Page 3/8 10 4; 100 kHz Pulse Train Output 18.01.2016 Changes preserved © Copyright Siemens AG integrated channels (DO) 10 Limitation of inductive shutdown voltage to L+ (-48 V) Switching capacity of the outputs ● with resistive load, max. 0.5 A ● on lamp load, max. 5 W Output voltage ● for signal "0", max. 0.1 V; with 10 kOhm load ● for signal "1", min. 20 V Output current ● for signal "1" rated value 0.5 A ● for signal "0" residual current, max. 0.1 mA Output delay with resistive load ● "0" to "1", max. 1 µs ● "1" to "0", max. 5 µs Switching frequency ● of the pulse outputs, with resistive load, max. 100 kHz Cable length ● shielded, max. 500 m ● unshielded, max. 150 m Analog inputs Number of analog inputs 2 integrated channels (AI) 2; 0 to 10V Input ranges ● Voltage Yes Input ranges (rated values), voltages ● 0 to +10 V Yes ● Input resistance (0 to 10 V) ≥100k ohms Cable length ● shielded, max. 100 m; twisted and shielded Analog outputs Number of analog outputs 0 Analog value generation Integration and conversion time/resolution per channel ● Resolution with overrange (bit including sign), max. 10 bit ● Integration time, parameterizable Yes ● Conversion time (per channel) 625 µs Encoder Connectable encoders ● 2-wire sensor 6ES7214-1AG40-0XB0 Page 4/8 Yes 18.01.2016 Changes preserved © Copyright Siemens AG 1. Interface Interface type PROFINET Physics Ethernet Isolated Yes automatic detection of transmission rate Yes Autonegotiation Yes Autocrossing Yes Functionality ● PROFINET IO Controller Yes ● PROFINET IO Device Yes ● Open IE communication Yes ● Web server Yes PROFINET IO Controller ● Transmission rate, max. 100 Mbit/s Services — Number of connectable IO Devices, max. 16 PROFINET IO Device Services — Shared device Yes — Number of IO Controllers with shared device, max. 2 Protocols Supports protocol for PROFINET IO Yes PROFIBUS Yes; CM 1243-5 required AS-Interface Yes Protocols (Ethernet) ● TCP/IP Yes Further protocols ● MODBUS Yes Communication functions S7 communication ● supported Yes ● as server Yes ● as client Yes Open IE communication ● TCP/IP Yes ● ISO-on-TCP (RFC1006) Yes ● UDP Yes Web server ● supported Yes ● User-defined websites Yes 6ES7214-1AG40-0XB0 Page 5/8 18.01.2016 Changes preserved © Copyright Siemens AG Number of connections ● overall 16; dynamically Test commissioning functions Status/control ● Status/control variable Yes ● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters Forcing ● Forcing Yes Diagnostic buffer ● present Yes Traces ● Number of configurable Traces 2; Up to 512 KB of data per trace are possible Integrated Functions Number of counters 6 Counting frequency (counter) max. 100 kHz Frequency meter Yes controlled positioning Yes Number of position-controlled positioning axes, max. 8 Number of positioning axes via pulse-direction interface 4; With integrated DO PID controller Yes Number of alarm inputs 4 Number of pulse outputs 4 Limit frequency (pulse) 100 kHz Potential separation Potential separation digital inputs ● Potential separation digital inputs 500V AC for 1 minute ● between the channels, in groups of 1 Potential separation digital outputs ● Potential separation digital outputs Yes ● between the channels No ● between the channels, in groups of 1 EMC Interference immunity against discharge of static electricity ● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Yes — Test voltage at air discharge 8 kV — Test voltage at contact discharge 6 kV Interference immunity to cable-borne interference 6ES7214-1AG40-0XB0 Page 6/8 18.01.2016 Changes preserved © Copyright Siemens AG ● Interference immunity on supply lines acc. to IEC 61000-4-4 Yes ● Interference immunity on signal cables acc. to IEC 61000-4-4 Yes Interference immunity against voltage surge ● on the supply lines acc. to IEC 61000-4-5 Yes Interference immunity against conducted variable disturbance induced by high-frequency fields ● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 Yes Emission of radio interference acc. to EN 55 011 ● Limit class A, for use in industrial areas Yes; Group 1 ● Limit class B, for use in residential areas Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 Degree and class of protection Degree of protection acc. to EN 60529 ● IP20 Yes Standards, approvals, certificates CE mark Yes UL approval Yes cULus Yes FM approval Yes RCM (formerly C-TICK) Yes Marine approval ● Marine approval Yes Ambient conditions Free fall ● Drop height, max. (in packaging) 0.3 m; five times, in dispatch package Ambient temperature during operation ● min. -20 °C ● max. 60 °C; Number of simultaneously activated inputs or outputs 7 or 5 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 14 or 10 at 55 °C horizontal or 45 °C vertical ● horizontal installation, min. -20 °C ● horizontal installation, max. 60 °C ● vertical installation, min. -20 °C ● vertical installation, max. 50 °C Ambient temperature during storage/transportation ● min. -40 °C ● max. 70 °C Air pressure acc. to IEC 60068-2-13 ● Storage/transport, min. 660 hPa ● Storage/transport, max. 1 080 hPa 6ES7214-1AG40-0XB0 Page 7/8 18.01.2016 Changes preserved © Copyright Siemens AG ● permissible operating height -1000 to 2000 m Relative humidity ● permissible range (without condensation) at 25 °C 95 % Vibrations ● Vibrations 2G wall mounting, 1G DIN rail ● Operation, tested according to IEC 60068-2-6 Yes Shock test ● tested according to IEC 60068-2-27 Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms Extended ambient conditions Pollutant concentrations — SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free Configuration Programming Programming language — LAD Yes — FBD Yes — SCL Yes Cycle time monitoring ● adjustable Yes Dimensions Width 110 mm Height 100 mm Depth 75 mm Weights Weight, approx. 415 g last modified: 13.01.2016 6ES7214-1AG40-0XB0 Page 8/8 18.01.2016 Changes preserved © Copyright Siemens AG