70509004 E EN 55022 And EN55024
2016-04-11
: Pdf 70509004-E En 55022 And En55024 70509004-E_EN_55022_and_EN55024 CertsReports 503983 ProductFiles
Open the PDF directly: View PDF .
Page Count: 52
Download | |
Open PDF In Browser | View PDF |
Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 CE EMC TEST REPORT For Cat5 KVM Extender Model: UKE-100 Trade Name: UNICLASS Issued to UNICLASS TECHNOLOGY CO., LTD. 4F, No. 98, Ming Chuan Rd., Hsin-Tien, Taipei, Taiwan, R.O.C. Issued by Compliance Certification Services Inc. No. 81-1, Lane 210, Bade Rd. 2, Luchu Hsiang, Taoyuan Hsien, (338) Taiwan, R.O.C. http://www.ccsemc.com.tw service@tw.ccsemc.com Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. Page 1 Total Page:52 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 TABLE OF CONTENTS 1 TEST RESULT CERTIFICATION.........................................................................................................3 2 EUT DESCRIPTION...............................................................................................................................4 3 TEST METHODOLOGY........................................................................................................................5 3.1 3.2 4 INSTRUMENT AND CALIBRATION ..................................................................................................6 4.1 4.2 5 FACILITIES.................................................................................................................................10 LABORATORY ACCREDITATIONS AND LISTINGS.............................................................11 SETUP OF EQUIPMENT UNDER TEST............................................................................................12 6.1 6.2 7 MEASURING INSTRUMENT CALIBRATION..........................................................................6 TEST AND MEASUREMENT EQUIPMENT .............................................................................6 FACILITIES AND ACCREDITATIONS.............................................................................................10 5.1 5.2 6 EUT SYSTEM OPERATION ........................................................................................................5 DECISION OF FINAL TEST MODE ...........................................................................................5 SETUP DIAGRAM......................................................................................................................12 SUPPORT EQUIPMENT ............................................................................................................12 POWERLINE CONDUCTED & RADIATED EMISSION TEST.......................................................13 7.1 7.2 7.3 7.4 7.5 LIMIT...........................................................................................................................................13 TEST PROCEDURE OF LINE CONDUCTED EMISSION ......................................................14 TEST PROCEDURE OF COMMON MODE CONDUCTED EMISSION FOR TELECOMMUNICATION PORT..............................................................................................15 TEST PROCEDURE OF RADIATED EMISSION.....................................................................16 TEST RESULTS ..........................................................................................................................17 8 POWER HARMONICS TEST..............................................................................................................20 9 POWER VOLTAGE FLUCTUATION / FLICKER TEST ..................................................................23 10 ELECTROSTATIC DISCHARGE (ESD) IMMUNITY TEST ............................................................26 11 RADIATED ELECTROMAGNETIC FIELD IMMUNITY TEST ......................................................32 12 FAST TRANSIENTS/BURST IMMUNITY TEST ..............................................................................35 13 SURGE IMMUNITY TEST..................................................................................................................38 14 CONDUCTED DISTRBANCE/INDUCED RADIO-FREQUENCY FIELD IMMUNITY TEST ......40 15 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST......................................................42 16 VOLTAGE DIPS / SHORT INTERRUPTIONS ..................................................................................44 APPENDIX I – PHOTOGRAPHS OF TEST SETUP................................................................................46 Page 2 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E 2 Date of Issue: September 10, 2007 EUT DESCRIPTION Product Cat5 KVM Extender Trade Name UNICLASS Model Number UKE-100 Model Discrepancy N/A Housing Type Metal EUT Power Rating Power adapter 1: Model: M7-10US08R-A I/P: AC 100-240V, 50-60Hz, 0.5A O/P: DC 9V, 1.11A Power adapter 2: Model: M7-10US08R-D I/P: AC 100-240V, 50-60Hz, 0.5A O/P: DC 9V, 1.11A Page 4 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E 3 Date of Issue: September 10, 2007 TEST METHODOLOGY 3.1 EUT SYSTEM OPERATION Software Used During the Test Windows XP 1. EMI test program (file name: EMCTEST) was loaded and executed in “Windows XP” mode. 2. The detect signal was sent to EUT. 3. Data was sent to the monitor, filling the screen with upper case of “H” patterns. Program Sequence 4. Test program sequentially all related I/O’s of Host PC include EUT and sent “H” patterns to all applicable output ports of Host PC. 5. Repeat 2 to 4. Operating System Remark: Test program is self-repeating throughout the test. 3.2 DECISION OF FINAL TEST MODE The EUT (model: UKE-100) comes with two types of power adapters (M7-10US08R-A & M7-10US08R-D) for sale. After the preliminary test, the power adapter with model M7-10US08R-A was found to emit the worst emissions and therefore had been tested under operating condition. 1. The following test mode was scanned during the preliminary test: Mode 1 Operating 2. After the preliminary scan, the following test mode was found to produce the highest emission level. Mode 1 Then, the EUT configuration and cable configuration of the above highest emission mode was chosen for all final test items. Page 5 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E 4 Date of Issue: September 10, 2007 INSTRUMENT AND CALIBRATION 4.1 MEASURING INSTRUMENT CALIBRATION The measuring equipment utilized to perform the tests documented in this report has been calibrated once a year or in accordance with the manufacturer's recommendations, and is traceable to recognized national standards. 4.2 TEST AND MEASUREMENT EQUIPMENT The following list contains measurement equipment used for testing. The equipment conforms to the requirement of CISPR 16-1, ANSI C63.2 and other required standards. Calibration of all test and measurement, including any accessories that may effect such calibration, is checked frequently to ensure the accuracy. Adjustments are made and correction factors are applied in accordance with the instructions contained in the respective manual. Equipment Used for Emission Measurement Open Area Test Site # 3 Name of Equipment Manufacturer Model Serial Number Calibration Due Spectrum Analyzer Agilnet E4411B MY41440314 N.C.R. Spectrum Analyzer R&S FSP30 100112 10/10/2007 EMI Test Receiver R&S ESVS30 828488/004 03/12/2008 Pre-Amplifier Anritsu MH648A M18767 08/30/2008 Pre-Amplifier MITEQ AFS42-00102650-42-10P-42 966468 04/26/2008 Bilog Antenna Schwazbeck VULB9163 144 03/30/2008 Horn Antenna EMCO 3115 00022250 04/15/2008 Loop Antenna EMCO 6502 2356 N.C.R. Turn Table Chance Most CM-T003-1 T807-6 N.C.R. Antenna Tower Chance Most CM-A003-1 A807-6 N.C.R. Controller CCS CC-C-1F N/A N.C.R. RF Switch Anritsu MP59B M53867 N.C.R. Site NSA CCS N/A N/A 05/04/2008 Decoupling Network FCC F-201-DCN-5-6MM 34 06/04/2008 Test S/W LabVIEW 6.1 (CCS OATS EMI SW V2.6) Remark: The measurement uncertainty is less than +/- 4.0235dB, which is evaluated as per the NAMAS NIS 81 and CISPR/A/291/CDV. Page 6 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Powerline Conducted Emissions Test Site Name of Equipment Manufacturer Model Serial Number Calibration Due Rohde & Schwarz ESHS30 828144/003 10/31/2007 Schaffner NNB41 03/10013 06/12/2008 LISN 10kHz-100MHz EMCO 3825/2 9106-1809 04/01/2008 ISN 9kHz-30MHz FCC FCC-TLISN-T4 20167 09/15/2007 EMI Test Receiver 9kHz-30MHz Two-Line V-Network 9kHz-30MHz Test S/W LABVIEW (V 6.1) Remark: The measurement uncertainty is less than +/- 2.81dB, which is evaluated as per the NAMAS NIS 81 and CISPR/A/291/CDV. Power Harmonic & Voltage Fluctuation/Flicker Measurement (EN 61000-3-2&-3-3) Name of Equipment Manufacturer Model Serial Number Calibration Due Harmonic & Flicker Tester EMC-Partner HAR1000-1P Test S/W 107 05/21/2008 HARCS (Ver. 4.0) Equipment Used for Immunity Measurement Name of Equipment ESD Simulator ESD Test Site (IEC 61000-4-2) Manufacturer Model Serial Number NoiseKen ESS-2001 ESS0210582 Calibration Due 11/15/2007 Radiated Electromagnetic Field Immunity Test Site (IEC 61000-4-3) Name of Equipment Manufacturer Model Serial Number Calibration Due Signal Generator 150 Watts 80-1000MHz Amplifier 30 Watts 0.8-3.0GHz Amplifier Power Meter Agilent 8648C 4108A05772 10/23/2007 Amplifier Research 150W1000M3 306730 N.C.R. Amplifier Research 30S1G3M1 306722 N.C.R. Boonton 4232A-01-02 98601 10/25/2007 Power Sensor Power Sensor Boonton Boonton 51011-EMC 51011-EMC 32920 32863 10/25/2007 10/25/2007 Log-Periodic Antenna Microwave Horn Antenna Amplifier Research Amplifier Research AT1080 AT4002A 306709 306750 N.C.R. N.C.R. RF Test System Controller Amplifier Research SC1000M3 306666 N.C.R. Field Probe 0.8-4.2GHz Amplifier Research Amplifier Research FP6001 DC7144A 305657 N/A 04/17/2008 N.C.R. 80-1000MHz Antenna Tower Amplifier Research Amplifier Research DC6180A TP2000 N/A N/A N.C.R. N.C.R. Probe Stand Amplifier Research PS2000 N/A N.C.R. Test S/W SW1005 (Release 1.4) Page 7 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Name of Equipment ECAT Control Center Capacitor Clamp Fast Transients/Burst Test Site (IEC 61000-4-4) Manufacturer Model Serial Number KeyTek KeyTek Test S/W Name of Equipment Date of Issue: September 10, 2007 E-Class Series 100 CCL-4 9502325 9503290 Calibration Due 03/08/2008 N.C.R. E400 Burstware (V4.19 (c)) Surge Immunity Test Site (IEC 61000-4-5) Manufacturer Model Serial Number Calibration Due ECAT Control Center KeyTek E-Class Series 100 9502325 03/08/2008 External Coupler / Decoupler For Telecom Lines KeyTek CM-TELCD 0104399 N.C.R. KeyTek CM-I / OCD 0103234 N.C.R. I/O Signal Line Coupler / Decoupler Test S/W E500 Surgeware (V4.19cc) CS Test Site (IEC 61000-4-6) Name of Equipment Manufacturer Model Serial Number Calibration Due Signal Generator Agilent 8648C 4108A05773 09/19/2007 75 Watts 10kHz-250MHz Amplifier Amplifier Research 75A250AM1 306334 N.C.R. Power Meter Boonton 4232A-01-02 98501 09/15/2007 Power Sensor Boonton 51011-EMC 32862 09/15/2007 Power Sensor Boonton 51011-EMC 32864 09/15/2007 FCC-801-M2-16A 03026 09/15/2007 FCC-801-M3-16A 03027 09/15/2007 FCC-801-T2 03016 09/15/2007 FCC-801-T4 03017 09/15/2007 F-203I-23mm 421 09/15/2007 FCC-801-150-50-CDN 03053&03054 09/15/2007 F-203I-CF-23mm 408 09/15/2007 FCC-801-T8-RJ45 04024 09/15/2007 Power Line Coupling Decoupling Network Power Line Coupling Decoupling Network Signal Line Coupling Decoupling Network Signal Line Coupling Decoupling Network Fischer Custom Communications, Inc. Fischer Custom Communications, Inc. Fischer Custom Communications, Inc. Fischer Custom Communications, Inc. Fischer Custom EM Injection Clamp Communications, Inc. Fischer Custom Passive Impedance Adapters Communications, Inc. Fischer Custom Calibration Fixture Communications, Inc. Signal Line Coupling Fischer Custom Decoupling Network Communications, Inc. Attenuator Amplifier Research HFP-575-3/6-NM NF201875106 N.C.R. Coupler Amplifier Research DC2600A 306621 N.C.R. Test S/W SW1005 (Release 1.4) Page 8 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Power Frequency Magnetic Field Immunity Test Site (IEC 61000-4-8) Name of Equipment Manufacturer Model Serial Number Calibration Due Magnetic Field Tester Frequency Converter Haefely Trench Extech Electronics MAG100.1 CFC-105 081436-02 810390 N.C.R. N.C.R. Digital Multimeter EMF Tester Electromagnetic Field DHA CM-312A ET93C-06-208-01 05/31/2008 TES 1390 020401598 05/17/2008 Voltage Dips/Short Interruption and Voltage Variation Immunity Test Site (IEC 61000-4-11) Name of Equipment Manufacturer Model Serial Number Calibration Due Dips/Interruption and Variations Simulator Test S/W Haefely Trench PLINE 1610 081568-06 08/06/2008 WinPATS (V. 3.26) Page 9 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E 5 Date of Issue: September 10, 2007 FACILITIES AND ACCREDITATIONS 5.1 FACILITIES All measurement facilities used to collect the measurement data are located at No.199, Chunghsen Road, Hsintien City, Taipei Hsien, Taiwan, R.O.C. Tel: 886-2-2217-0894 / Fax: 886-2-2217-1029 No.11, Wugong 6th Rd., Wugu Industrial Park, Taipei Hsien 248, Taiwan Tel: 886-2-2299-9720 / Fax: 886-2-2298-4045 No.81-1, Lane 210, Bade 2nd Rd., Luchu Hsiang, Taoyuan Hsien 338, Taiwan Tel: 886-3-324-0332 / Fax: 886-3-324-5235 The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and CISPR Publication 22. Page 10 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 5.2 LABORATORY ACCREDITATIONS AND LISTINGS The test facilities used to perform Electromagnetic compatibility tests are registered or accredited by the organizations listed in the following table which includes the recognized scope specifically. Country Agency Scope of Accreditation USA A2LA EN 55011, EN 55014-1/2, CISPR 11, CISPR 14-1/2, EN 55022, EN 55015, CISPR 22, CISPR 15, AS/NZS 3548, VCCI V3 (2001), CFR 47, FCC Part 15/18, CNS 13783-1, CNS 13439, CNS 13438, CNS 13803, CNS 14115, EN 55024, IEC 801-2, IEC 801-3, IEC 801-4, IEC/EN 61000-3-2, IEC/EN 61000-3-3, IEC/EN 61000-4-2/3/4/5/6/8/11, EN 50081-1/ EN 61000-6-3, EN 50081-2/EN 61000-6-4, EN 50081-2/EN 61000-6-1: 2001 USA FCC 3/10 meter Open Area Test Sites (93105, 90471) / 3M Semi Anechoic Chamber (965860) to perform FCC Part 15/18 measurements Japan VCCI 3/10 meter Open Area Test Sites to perform conducted/radiated measurements Logo 93105, 90471 965860 R-393/1066/725/879 C-402/747/912 NEMKO EN 50081-1/2, EN 50082-1/2, IEC 61000-6-1/2, EN 50091-2, EN 50130-4, EN 55011, EN 55013, EN 55014-1/2, EN 55015, EN 55022, EN 55024, EN 61000-3-2/3, EN 61326-1, IEC 61000-4-2/3/4/5/6/8/11, EN 60601-1-2, EN 300 328, EN 300 422-2, EN 301 419-1, EN 301 489-01/03/07/08/09/17, EN 301 419-2/3, EN 300 454-2, EN 301 357-2 Taiwan TAF EN 300 328, EN 300 220-1, EN 300 220-2, EN 300 220-3, 47 CFR FCC Part 15 Subpart C, EN 61000-3-2, EN 61000-3-3, CNS 13439, CNS 13783-1, CNS 14115, CNS 13438, AS/NZS CISPR 22, CNS 13022-1, IEC 61000-4-2/3/4/5/6/8/11, CNS 13022-2/3 Taiwan BSMI CNS 13438, CNS 13783-1, CNS 13439, CNS 14115 SL2-IS-E-0014 SL2-IN-E-0014 SL2-A1-E-0014 SL2-R1-E-0014 SL2-R2-E-0014 SL2-L1-E-0014 Canada Industry Canada 3/10 meter Open Area Test Sites (IC 2324C-3, IC 2324C-5) / 3M Semi Anechoic Chamber (IC 6106) IC 2324C-3 IC 2324C-5 IC 6106 Norway ELA 124a ELA 124b ELA 124c * No part of this report may be used to claim or imply product endorsement by A2LA or any agency of the US Government. Page 11 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E 6 Date of Issue: September 10, 2007 SETUP OF EQUIPMENT UNDER TEST 6.1 SETUP DIAGRAM See test photographs attached in Appendix I for the actual connections between EUT and support equipment. 6.2 SUPPORT EQUIPMENT No Equipment Trade Name Model Serial No. FCC ID Data Cable Power Cord 1. PC HP DX-6120 SGH5330GK7 FCC DoC N/A Unshielded, 1.8m 2. PC HP PL926AV SGH528048P FCC DoC N/A Unshielded, 1.8m 3. CRT Monitor Samsung 959NF AQ19H2RT706139P FCC DoC Shielded, 1.8m with 2 cores Shielded, 1.8m with 2 cores Unshielded, 1.8m AC I/P: Unshielded, 1.8m DC O/P: Unshielded, 1.8m with a core AC I/P: Unshielded, 1.8m DC O/P: Unshielded, 1.8m with a core AC I/P: Unshielded, 1.8m DC O/P: Unshielded, 1.8m with a core 4. LCD Monitor Samsung 173P DI17H4JXB04968Y FCC DoC 5. LCD Monitor SAMSUNG 959NF AQ19H2RT706121B FCC DoC Shielded, 1.8m with 2 cores 6. LCD Monitor LG L1740PQ 503KGXA2K858 BEJL17NU Shielded, 1.8m with 2 cores 7. PS/2 Keyboard Logitech Y-SJ17 SY528UK FCC DoC Shielded, 1.8m N/A 8. PS/2 Keyboard Logitech Y-SJ17 SY528UK FCC DoC Shielded, 1.8m N/A 9. PS/2 Keyboard hp KB-0316 355630-AB1 FCC DoC Shielded, 1.8m N/A 10. PS/2 Keyboard COMPAQ KB-0133 N/A FCC DoC Shielded, 1.8m N/A 11. PS/2 Mouse Logitech M-S34 HCA25200400 DZL211029 Shielded, 1.8m N/A 12. PS/2 Mouse Logitech M-S34 HCA25200475 DZL211029 Shielded, 1.8m N/A 13. PS/2 Mouse Logitech M-S34 LZC85106992 14. PS/2 Mouse Logitech M-S34 HCA25200251 15. Printer EPSON STYLUS C60 DR3K039633 FCC DoC Shielded, 1.8m Unshielded, 1.8m 16. Printer EPSON STYLUS C60 DR3K041995 FCC DoC Shielded, 1.8m Unshielded, 1.8m 17. Multimedia Earphone Labtec Axis-301 N/A FCC DoC Unshielded, 1.8m N/A 18. Multimedia Earphone Ergotech ET-E220 N/A FCC DoC Unshielded, 1.8m N/A 19. Modem ACEEX DM-1414 304012269 FCC DoC Shielded, 1.8m N/A DZL211029 Shielded, 1.8m N/A IFAXDM1414 Shielded, 1.8m Unshielded, 1.8m Remark: All the above equipment/cables were placed in worse case positions to maximize emission signals during emission test. Grounding: Grounding was in accordance with the manufacturer’s requirements and conditions for the intended use. Page 12 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E 7 Date of Issue: September 10, 2007 POWERLINE CONDUCTED & RADIATED EMISSION TEST 7.1 LIMIT Maximum permissible level of Line Conducted Emission Frequency (MHZ) 0.15 - 0.5 0.50 - 5.0 5.0 - 30.0 Class A (dBuV/m) Quasi-peak Average 79 66 73 60 73 60 Class B (dBuV/m) Quasi-peak Average 66 - 56 56 - 46 56 46 60 50 Remark: The lower limit shall apply at the transition frequency. Maximum permissible level of Common Mode Conducted Emission (Telecommunication Ports) CLASS A Frequency (MHz) 0.15 - 0.5 0.5 - 30.0 Voltage Limit (dBuV) Quasi-peak Average 97 – 87 84 - 74 87 74 Current Limit (dBuA) Quasi-peak Average 53 – 43 40 – 30 43 30 Remark: The lower limit shall apply at the transition frequency. CLASS B Frequency (MHz) 0.15 - 0.5 0.5 - 30.0 Voltage Limit (dBuV) Quasi-peak Average 84 - 74 74 - 64 74 64 Current Limit (dBuA) Quasi-peak Average 40 – 30 30 – 20 30 20 Remark: 1. The lower limit shall apply at the transition frequency. 2. According to Note 3 on table 4 of EN 55022: 1998 standard, a relaxation of 10 dB over the frequency range of 6 MHz to 30 MHz is allowed for high-speed services having significant spectral density in this band. However, this relaxation is restricted to the common mode disturbance converted by the cable from the wanted signal. Maximum permissible level of Radiated Emission measured at 10 meter Frequency (MHz) 30 – 230 230 - 1000 Class A (dBuV/m) Quasi-peak 40 47 Class B (dBuV/m) Quasi-peak 30 37 Remark: The lower limit shall apply at the transition frequency. Page 13 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 7.2 TEST PROCEDURE OF LINE CONDUCTED EMISSION Procedure of Preliminary Test The EUT was set up as per the test configuration to simulate typical usage per the user’s manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is placed on the ground plane as per EN 55022 (see Test Facility for the dimensions of the ground plane used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the ground plane. Support equipment, if needed, was placed as per EN 55022. All I/O cables were positioned to simulate typical actual usage as per EN 55022. The test equipment EUT installed received AC power, 230VAC/50Hz, through a Line Impedance Stabilization Network (LISN), which supplied power source and was grounded to the ground plane. All support equipments received power from a second LISN. The EUT test program was started. Emissions were measured on each current carrying line of the EUT using an EMI Test Receiver connected to the LISN powering the EUT. The Receiver scanned from 150kHz to 30MHz for emissions in each of the test modes. During the above scans, the emissions were maximized by cable manipulation. The test mode(s) described in Item 3.2 were scanned during the preliminary test. After the preliminary scan, we found the test mode described in Item 3.2 producing the highest emission level. The EUT configuration and cable configuration of the above highest emission level were recorded for reference of the final test. Procedure of Final Test EUT and support equipment were set up on the test bench as per the configuration with highest emission level in the preliminary test. A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions. Emission frequency and amplitude were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit. The test data of the worst-case condition(s) was recorded. Page 14 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 7.3 TEST PROCEDURE OF COMMON MODE CONDUCTED EMISSION FOR TELECOMMUNICATION PORT Selecting ISN for unscreened cable or a current probe for screened cable to take measurement. The port of the EUT was connected to the remote side support equipment through the ISN/Current Probe and communication in normal condition. Making a overall range scan by using the test receiver controlled by controller and record at least six highest emissions for showing in the test report. Emission frequency and amplitude were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit. In case of measuring on the screened cable, the current limit shall be applied, otherwise the voltage limit should be applied. The following test mode was scanned during the preliminary test: Not applicable, because EUT has no LAN port or modem port. Page 15 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 7.4 TEST PROCEDURE OF RADIATED EMISSION Procedure of Preliminary Test The equipment was set up as per the test configuration to simulate typical usage per the user’s manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8 meters is used which is placed on the ground plane. When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the ground plane. Support equipment, if needed, was placed as per EN 55022. All I/O cables were positioned to simulate typical usage as per EN 55022. The EUT received AC power source, 230VAC/50Hz, from the outlet socket under the turntable. All support equipments received power from another socket under the turntable. The antenna was placed at 10 meter away from the EUT as stated in EN 55022. The antenna connected to the Spectrum Analyzer via a cable and at times a pre-amplifier would be used. The Analyzer / Receiver quickly scanned from 30MHz to 1000MHz. The EUT test program was started. Emissions were scanned and measured rotating the EUT to 360 degrees and positioning the antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal polarization, to maximize the emission reading level. The test mode(s) described in Item 3.2 were scanned during the preliminary test: After the preliminary scan, we found the test mode described in Item 3.2 producing the highest emission level. The EUT and cable configuration, antenna position, polarization and turntable position of the above highest emission level were recorded for the final test. Procedure of Final Test EUT and support equipment were set up on the turntable as per the configuration with highest emission level in the preliminary test. The Analyzer / Receiver scanned from 30MHz to 1000MHz. Emissions were scanned and measured rotating the EUT to 360 degrees, varying cable placement and positioning the antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal polarization, to maximize the emission reading level. Recorded at least the six highest emissions. Emission frequency, amplitude, antenna position, polarization and turntable position were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit and only Q.P. reading is presented. The test data of the worst-case condition(s) was recorded. Page 16 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 7.5 TEST RESULTS Powerline Conducted Emission Operation Mode: Mode 1 Temperature: 25oC Tested by: Eric Cheng Test Date: August 10, 2007 Humidity: 55% RH Freq. (MHz) QP Reading (dBuV) AV Reading (dBuV) Corr. factor (dB) QP Result (dBuV) AV Result (dBuV) QP Limit (dBuV) AV Limit (dBuV) QP Margin (dB) AV Margin Note (dB) 0.160 51.270 48.700 0.180 51.450 48.880 65.464 55.464 -14.014 -6.584 L1 0.213 48.090 45.700 0.100 48.190 45.800 63.088 53.088 -14.898 -7.288 L1 0.372 44.960 41.710 0.100 45.060 41.810 58.456 48.456 -13.396 -6.646 L1 0.532 46.610 43.640 0.100 46.710 43.740 56.000 46.000 -9.290 -2.260 L1 9.453 43.860 39.010 0.645 44.505 39.655 60.000 50.000 -15.495 -10.345 L1 11.175 38.100 34.560 0.724 38.824 35.284 60.000 50.000 -21.176 -14.716 L1 0.156 46.640 42.520 0.188 46.828 42.708 65.674 55.674 -18.846 -12.966 L2 0.213 45.410 42.520 0.100 45.510 42.620 63.088 53.088 -17.578 -10.468 L2 0.266 40.950 38.560 0.100 41.050 38.660 61.242 51.242 -20.192 -12.582 L2 0.532 44.590 43.700 0.100 44.690 43.800 56.000 46.000 -11.310 -2.200 L2 9.230 34.440 29.670 0.623 35.063 30.293 60.000 50.000 -24.937 -19.707 L2 11.086 31.470 26.960 0.722 32.192 27.682 60.000 50.000 -27.808 -22.318 L2 Remark: 1. Measuring frequencies from 0.15 MHz to 30MHz. 2. The emissions measured in frequency range from 0.15 MHz to 30MHz were made with an instrument using Quasi-peak detector and average detector. 3. The IF bandwidth of SPA between 0.15MHz and 30MHz was 10kHz; the IF bandwidth of Test Receiver between 0.15MHz and 30MHz was 9kHz; 4. L1 = Line One (Live Line) / L2 = Line Two (Neutral Line) Page 17 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Test Plots Conducted emissions (Line 1) Conducted emissions (Line 2) Page 18 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Radiated Emission Operation Mode: Mode 1 Test Date: August 13, 2007 o Temperature: 26 C Tested by: Eric Cheng Humidity: 55% RH Polarity: Ver. / Hor. Frequency (MHz) Ant. Pol. (H/V) Detector Mode (PK/QP) Reading (dBuV) Correction Factor (dB/m) Result (dBuV/m) Limit 10m (dBuV/m) Margin (dB) 59.10 V QP 9.50 12.99 22.49 30.00 -7.51 141.55 V QP 10.50 9.32 19.82 30.00 -10.18 163.38 V QP 8.80 10.22 19.02 30.00 -10.98 253.10 V QP 6.40 14.38 20.78 37.00 -16.22 536.83 V QP 6.20 20.90 27.10 37.00 -9.90 648.37 V QP 5.80 22.74 28.54 37.00 -8.46 55.27 H QP 10.10 13.20 23.30 30.00 -6.70 134.27 H QP 15.50 9.79 25.29 30.00 -4.71 182.78 H QP 8.10 11.33 19.43 30.00 -10.57 253.10 H QP 12.00 14.38 26.38 37.00 -10.62 612.00 H QP 6.40 22.38 28.78 37.00 -8.22 752.65 H QP 4.90 23.59 28.49 37.00 -8.51 Remark: 1. Measuring frequencies from 30MHz to 1GHz. 2. Radiated emissions measured in frequency range from 30MHz to 1000MHz were made with an instrument using Peak /Quasi-peak detector mode. 3. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 4. The IF bandwidth of SPA between 30MHz and 1GHz was 100 kHz. Page 19 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E 8 Date of Issue: September 10, 2007 POWER HARMONICS TEST Port : AC mains Basic Standard : EN 61000-3-2 Limits : Tested by : Eric Cheng Temperature : 25oC Humidity : 55% RH CLASS A; CLASS B; CLASS C; CLASS D Limit: Limits for Class A equipment Limits for Class D equipment Harmonics Max. permissible Harmonics Order harmonics current Order n A n Max. permissible harmonics current per watt mA/W Odd harmonics Max. permissible harmonics current A Odd harmonics only 3 2.30 3 3.4 2.30 5 1.14 5 1.9 1.14 7 0.77 7 1.0 0.77 9 0.40 9 0.5 0.40 11 0.33 11 0.35 0.33 13 0.21 13 0.30 0.21 15<=n<=39 3.85/n 0.15x15/n 15<=n<=39 0.15x15/n Even harmonics 2 1.08 4 0.43 6 0.30 8<=n<=40 0.23x8/n Page 20 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Block Diagram of Test Setup: Harmonics & Flicker Analyzer + Power Source Power Cord EUT Support Units 0.8m Test Procedure: a. b. The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated to produce the maximum harmonic components under normal operating conditions for each successive harmonic component in turn. The correspondent test program of test instrument to measure the current harmonics emanated from EUT is chosen. The measure time shall be not less than the time necessary for the EUT to be exercised. Test Result: No non-compliance noted. Page 21 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Harmonic Emission - IEC 61000-3-2 , EN 61000-3-2 , (EN60555-2) Cat5 KVM Extender UKE-100 Eric Cheng Remarks Full Bar Temp : 25'C Humidity : 55% RH : Actual Values Empty Bar : Maximum Values Blue : Current , Green : Voltage , Red : Failed According to EN 61000-3-2, for the following categories of equipment, limits are not specified in this standard: Remark: 1. Limits may be defined in a future amendment or revision of the standard. Equipment with a rated power of 75W or less, other than lighting equipment. 2. This value may be reduced from 75W to 50W in the future, subject to approval by National Committees at that time. Page 22 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E 9 Date of Issue: September 10, 2007 POWER VOLTAGE FLUCTUATION / FLICKER TEST Port : AC mains Basic Standard : EN 61000-3-3 Limits : §5 of EN 61000-3-3 Tested by : Eric Cheng Temperature : 25oC Humidity : 55% RH Limit: TEST ITEM LIMIT REMARK Pst 1.0 Pst means short-term flicker indicator. Plt 0.65 Plt means long-term flicker indicator. Tdt (ms) 500 Tdt means maximum time that dt exceeds 3 %. dmax (%) 4% dmax means maximum relative voltage change. dc (%) 3.3% dc means relative steady-state voltage change Block Diagram of Test Setup: Harmonics & Flicker Analyzer + Power Source Power Cord EUT Support Units 0.8m Page 23 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Test Procedure: a. The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated to produce the most unfavorable sequence of voltage changes under normal operating conditions. b. During the flick measurement, the measure time shall include that part of whole operation cycle in which the EUT produce the most unfavorable sequence of voltage changes. The observation period for short-term flicker indicator is 10 minutes and the observation period for long-term flicker indicator is 2 hours. Test Result: No non-compliance noted. Page 24 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Measurement Date : 2007/8/10 PM 09:22:1 V4.15 File : Cat5 KVM Extender UKE-100 Eric Cheng Remarks Temp : 25'C Humidity : 55% RH Urms = 229.9V Freq = 49.948 Range: 0.5 A Irms = 0.043A Ipk 0.240A cf = 5.528 P 3.939W S 9.991VA pf = 0.394 = Test - Time : = = 1 x 10min = 10min ( 100 %) LIN (Line Impedance Network) : Limits : Plt : L: 0.24ohm +j0.15ohm N: 0.16ohm +j0.10ohm 0.65 Pst : 1.00 dmax : 4.00 % dc : 3.30 % dtLim: 3.30 % dt>Lim: 500ms P3s P1s Test completed, Result: PASSED Plt = 0.076 Pst P50s P10s P0.1s Fli dmax dc [%] [%] 0.000 0.000 dt>Lim [ms] 1 0.076 0.010 0.010 0.011 0.015 0.021 0.002 0.000 Page 25 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 10 ELECTROSTATIC DISCHARGE (ESD) IMMUNITY TEST Port : Enclosure Basic Standard : IEC 61000-4-2 Test Level : ± 8 kV (Air Discharge) ± 4 kV (Contact Discharge) ± 4 kV (Indirect Discharge) Performance Criterion : B (Standard Required) Tested by : Eric Cheng Temperature : 25oC Humidity : 55% RH Pressure : 1005mbar Block Diagram of Test Setup: (The 470 k ohm resistors are installed per standard requirement.) VCP EUT & its direct Support Units Indirect Support units HCP >1m Wooden Table 0.8m Ground Reference Plane Page 26 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Test Procedure: 1. The EUT was located 0.1 m minimum from all side of the HCP. 2. The indirect support units were located 1 m minimum away from the EUT, but direct support unit was/were located at same location as EUT on the HCP and keep at a distance of 10 cm with EUT. 3. A scroll ‘H’ test program was loaded and executed in Windows XP mode. 4. The EUT sent above message to LCD monitor and related peripherals through the test. 5. Active the communication function if the EUT with such port(s). 6. As per the requirement of EN 55024; applying direct contact discharge at the sides other than front of EUT at minimum 50 discharges (25 positive and 25 negative) if applicable, can’t be applied direct contact discharge side of EUT then the indirect discharge shall be applied. One of the test points shall be subjected to at least 50 indirect discharge (contact) to the front edge of horizontal coupling plane. 7. Other parts of EUT where it is not possible to perform contact discharge then selecting appropriate points of EUT for air discharge, a minimum of 10 single air discharges shall be applied. 8. The application of ESD to the contact of open connectors is not required. 9. The EUT direct connection units also need to be applied ESD at the port of EUT cable connected. 10. To simulate a single ESD event (either by air or by contact discharge), the charge on the EUT shall be removed prior to each applied ESD pulse. The charge on the metallic point or part to which the ESD pulse is to be applied, for example, connector shells, battery charge pins, metallic antennae, shall be removed prior to each applied ESD test pulse. When one or several metallic accessible parts are subject to the ESD test, the charge shall be removed from the point where the ESD pulse is to be applied, as no guarantee can be given about the resistance between this and other accessible points on the product. 11. Putting a mark on EUT to show tested points. The following test condition was followed during the tests. Remark: As per IEC 61000-4-2, two 470k bleed resistors cable is connected between the EUT and HCP during the test applicable for power ungrounded or battery operating unit only. The electrostatic discharges were applied as follows: Amount of discharge Voltage Coupling Min. 20 / Point Min. 50 / Point Min. 50 / Point Min. 50 / Point Min. 50 / Point Min. 50 / Point ± 8 kV ± 4 kV ± 4 kV ± 4 kV ± 4 kV ± 4 kV Air Discharge Contact Discharge Indirect Discharge HCP (Front) Indirect Discharge VCP (Right) Indirect Discharge VCP (Left) Indirect Discharge VCP (Back) Test Result (Criterion) A A A A A A Remark: For tested points to EUT, refer to the enclosed pages. Be aware that the Blue mark is for contact discharge, and the red mark is for air discharge. Page 27 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Performance & Result: Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be restored by the operation of controls. PASS FAIL Observation: No function degraded during the tests. Page 28 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 The Tested Points of EUT Page 29 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Page 30 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Page 31 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 11 RADIATED ELECTROMAGNETIC FIELD IMMUNITY TEST Port : Enclosure Basic Standard : IEC 61000-4-3 Requirements : 3 V/m / with 80% AM. 1 kHz Modulation. Performance Criterion : A (Standard Required) Tested by : Eric Cheng Temperature : 25oC Humidity : 55% RH Pressure : 1005mbar Block Diagram of Test Setup: 3 meter 7x3x3 EUT & Support Units 1.5 meter 0.8m Power Amp PC Controller to control S.G. & PA as well as forward power Signal Generator EUT Monitoring by using a camera Control Room Page 32 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Test Procedure: 1. The EUT was located at the edge of supporting table keep 3 meter away from transmitting antenna, it just the calibrated square area of field uniformity. The support units were located outside of the uniformity area, but the cable(s) connected with EUT were exposed to the calibrated field as per IEC 61000-4-3. 2. Setting the testing parameters of RS test software per IEC 61000-4-3. 3. Performing the pre-test at each side of with double specified level (6V/m) at 4% steps. 4. From the result of pre-test in step 5, choice the worst side of EUT for final test from 80 MHz to 1000 MHz at 1% steps. 5. Recording the test result in following table. Preliminary test conditions: Test level Steps Dwell Time : 6V/m : 4 % of fundamental : 3 sec Freq. Range (MHz) Field Modulation Polarity Position Test Result (Criterion) 80-1000 6V/m Yes H Front A 80-1000 6V/m Yes V Front A 80-1000 6V/m Yes H Right A 80-1000 6V/m Yes V Right A 80-1000 6V/m Yes H Back A 80-1000 6V/m Yes V Back A 80-1000 6V/m Yes H Left A 80-1000 6V/m Yes V Left A Final test conditions: Test level Steps Dwell Time : 3V/m : 1 % of fundamental : 3 sec Freq. Range (MHz) Field Modulation Polarity Position Test Result (Criterion) 80-1000 3V/m Yes H Front A 80-1000 3V/m Yes V Front A Page 33 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Performance & Result: Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be restored by the operation of controls. PASS FAIL Observation: No function degraded during the tests. Page 34 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 12 FAST TRANSIENTS/BURST IMMUNITY TEST Port : On Power Supply Lines and Data Line Basic Standard : IEC 61000-4-4 Requirements : ± 1 kV for Power Supply Line Performance Criterion : B (Standard Required) Tested by : Eric Cheng Temperature : 25oC Humidity : 55% RH Pressure : 1005mbar Block Diagram of Test Setup: EUT AC Line EFT/Burst/ Surge Generator Controller Computer Support Units 10cm Ground Reference Plane Non-Conductive Table Comm. Line ≧ 3 m To Load 10cm EUT AC Line Burst Generator 10cm Injection Clamp Ground Reference Plane Page 35 Non-Conductive Table Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Test Procedure: 1. 2. 3. 4. 5. The EUT and support units were located on a wooden table 0.1 m away from ground reference plane. A 0.5m long power cord was attached to EUT during the test. The length of communication cable between communication port and clamp was keeping within 0.5m. Injected test voltage to the EUT ports from minimum to standard request or client request. Recording the test result as shown in following table. Test conditions: Impulse Frequency : 5kHz Tr/Th : 5/50ns Burst Duration : 15ms Burst Period : 3Hz Inject Line Voltage kV Inject Method Line Neutral PE Line + Neutral L + PE N + PE L + N + PE RJ45 port (LAN cable) RJ11 port (Line cable) ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±0.5 ±0.5 Direct Direct Direct Direct Direct Direct Direct Clamp Clamp Page 36 Test Result (Criterion) A A N/A A N/A N/A N/A N/A N/A Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Performance & Result: Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be restored by the operation of controls. PASS FAIL Observation: No function degraded during the tests. Page 37 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 13 SURGE IMMUNITY TEST Port : Power Cord Basic Standard : IEC 61000-4-5 Requirements : ± 1 kV (Line to Line) Performance Criterion : B (Standard Required) Tested by : Eric Cheng Temperature : 25oC Humidity : 55% RH Pressure : 1005mbar Block Diagram of Test Setup: To AC Source Surge Immunity Test EUT & Support Units 0.8m Controller Computer Test Procedure: 1. The EUT and support units were located on a wooden table 0.8 m away from ground floor. 2. Injected test voltage to the EUT ports from minimum to standard request or client request. 3. Recording the test result as shown in following table. Page 38 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Test conditions: Voltage Waveform Current Waveform Polarity Phase angle Number of Test : : : : : 1.2/50 us 8/20 us Positive/Negative 0o, 90o, 270o 5 Coupling Line Line + Neutral L + PE N + PE T, R-Ground L1, 2, 3, 4-G Voltage (kV) 1 2 2 1 1 Coupling Method Capacitive Capacitive Capacitive Capacitive Capacitive Polarity Pos./ Neg. Pos./ Neg. Pos./ Neg. Pos./ Neg. Pos./ Neg. Test Result (Criterion) A N/A N/A N/A N/A Performance & Result: Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be restored by the operation of controls. PASS FAIL Observation: No function degraded during the tests. Page 39 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 14 CONDUCTED DISTRBANCE/INDUCED RADIO-FREQUENCY FIELD IMMUNITY TEST Port : AC Port and Data Line Basic Standard : IEC 61000-4-6 Requirements : 3 V with 80% AM. 1 kHz Modulation. Injection Method : CDN-M2 for Power Cord Performance Criterion : A (Standard Required) Tested by : Eric Cheng Temperature : 25oC Humidity : 55% RH Pressure : 1005mbar Block Diagram of Test Setup: Side View: 0.1m< L <0.3m 10 cm isolation supporter EUT and Support units Power Amplifier CDN PC Controller Ground Reference Plane 0.1m95 70 30 25 C Voltage Dips Voltage Interruptions Test Level % UT <5 Test Interval : Min. 10 sec. Tested by : Eric Cheng Temperature : 25oC Humidity : 55% RH Pressure : 1005mbar Reduction (%) >95 Duration ( periods ) 250 Performance Criteria C Block Diagram of Test Setup: To AC Source Dips/Interruption and Variations Simulator EUT & Support Units 0.8m Controller Computer Test Procedure: 1. 2. 3. 4. The EUT and support units were located on a wooden table, 0.8 m away from ground floor. Setting the parameter of tests and then Perform the test software of test simulator. Conditions changes to occur at 0 degree crossover point of the voltage waveform. Recording the test result in test record form. Page 44 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 Test conditions The duration with a sequence of three dips/interruptions with interval of 10 s minimum (Between each test event ) Voltage Dips: Test Level % UT Reduction (%) Duration (periods) Observation Meet Performance Criteria 0 100 0.5 Normal A 70 30 25 Normal A Duration (periods) Observation Meet Performance Criteria 250 EUT shut down, but can be recovered manually as the events disappeared. C Voltage Interruptions: Test Level % UT 0 Reduction (%) 100 Performance & Result: Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be restored by the operation of controls. PASS FAIL Page 45 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 APPENDIX I – PHOTOGRAPHS OF TEST SETUP POWERLINE CONDUCTED EMISSION TEST (EN 55022) Page 46 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 RADIATED EMISSION TEST (EN 55022) Page 47 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 POWER HARMONIC & VOLTAGE FLUCTUATION / FLICKER TEST (EN 61000-3-2/EN 61000-3-3) Page 48 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 ELECTROSTATIC DISCHARGE TEST (IEC 61000-4-2) RADIATED ELECTROMAGNETIC FIELD TEST (IEC 61000-4-3) Page 49 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 FAST TRANSIENTS/BURST TEST (IEC 61000-4-4) SURGE IMMUNITY TEST (IEC 61000-4-5) Page 50 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 CONDUCTED DISTURBANCE, INDUCED BY RADIO-FREQUENCY FIELDS TEST (IEC 61000-4-6) POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST (IEC 61000-4-8) Page 51 Rev. 00 Compliance Certification Services Inc. Report No.: 70509004-E Date of Issue: September 10, 2007 VOLTAGE DIPS / INTERRUPTION TEST (IEC 61000-4-11) Page 52 Rev. 00
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Create Date : 2007:09:11 05:05:03Z Modify Date : 2007:09:11 13:07:23+08:00 Page Count : 52 Creation Date : 2007:09:11 05:05:03Z Mod Date : 2007:09:11 13:07:23+08:00 Producer : Acrobat Distiller 5.0 (Windows) Author : gina_lo Metadata Date : 2007:09:11 13:07:23+08:00 Creator : gina_lo Title : Microsoft Word - 70509004-E EN 55022 and EN55024.docEXIF Metadata provided by EXIF.tools