Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

CE EMC

TEST REPORT

For

Cat5 KVM Extender

Model: UKE-100

Trade Name: UNICLASS

Issued to

UNICLASS TECHNOLOGY CO., LTD.
4F, No. 98, Ming Chuan Rd., Hsin-Tien,
Taipei, Taiwan, R.O.C.

Issued by

Compliance Certification Services Inc.
No. 81-1, Lane 210, Bade Rd. 2, Luchu Hsiang,
Taoyuan Hsien, (338) Taiwan, R.O.C.
http://www.ccsemc.com.tw
service@tw.ccsemc.com

Note: This report shall not be reproduced except in full, without the written approval of Compliance
Certification Services Inc. This document may be altered or revised by Compliance Certification
Services Inc. personnel only, and shall be noted in the revision section of the document.

Page 1

Total Page:52
Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

TABLE OF CONTENTS
1

TEST RESULT CERTIFICATION.........................................................................................................3

2

EUT DESCRIPTION...............................................................................................................................4

3

TEST METHODOLOGY........................................................................................................................5
3.1
3.2

4

INSTRUMENT AND CALIBRATION ..................................................................................................6
4.1
4.2

5

FACILITIES.................................................................................................................................10
LABORATORY ACCREDITATIONS AND LISTINGS.............................................................11

SETUP OF EQUIPMENT UNDER TEST............................................................................................12
6.1
6.2

7

MEASURING INSTRUMENT CALIBRATION..........................................................................6
TEST AND MEASUREMENT EQUIPMENT .............................................................................6

FACILITIES AND ACCREDITATIONS.............................................................................................10
5.1
5.2

6

EUT SYSTEM OPERATION ........................................................................................................5
DECISION OF FINAL TEST MODE ...........................................................................................5

SETUP DIAGRAM......................................................................................................................12
SUPPORT EQUIPMENT ............................................................................................................12

POWERLINE CONDUCTED & RADIATED EMISSION TEST.......................................................13
7.1
7.2
7.3
7.4
7.5

LIMIT...........................................................................................................................................13
TEST PROCEDURE OF LINE CONDUCTED EMISSION ......................................................14
TEST PROCEDURE OF COMMON MODE CONDUCTED EMISSION FOR
TELECOMMUNICATION PORT..............................................................................................15
TEST PROCEDURE OF RADIATED EMISSION.....................................................................16
TEST RESULTS ..........................................................................................................................17

8

POWER HARMONICS TEST..............................................................................................................20

9

POWER VOLTAGE FLUCTUATION / FLICKER TEST ..................................................................23

10

ELECTROSTATIC DISCHARGE (ESD) IMMUNITY TEST ............................................................26

11

RADIATED ELECTROMAGNETIC FIELD IMMUNITY TEST ......................................................32

12

FAST TRANSIENTS/BURST IMMUNITY TEST ..............................................................................35

13

SURGE IMMUNITY TEST..................................................................................................................38

14

CONDUCTED DISTRBANCE/INDUCED RADIO-FREQUENCY FIELD IMMUNITY TEST ......40

15

POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST......................................................42

16

VOLTAGE DIPS / SHORT INTERRUPTIONS ..................................................................................44

APPENDIX I – PHOTOGRAPHS OF TEST SETUP................................................................................46

Page 2

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

2

Date of Issue: September 10, 2007

EUT DESCRIPTION

Product

Cat5 KVM Extender

Trade Name

UNICLASS

Model Number

UKE-100

Model Discrepancy

N/A

Housing Type

Metal

EUT Power Rating

Power adapter 1:
Model: M7-10US08R-A
I/P: AC 100-240V, 50-60Hz, 0.5A
O/P: DC 9V, 1.11A
Power adapter 2:
Model: M7-10US08R-D
I/P: AC 100-240V, 50-60Hz, 0.5A
O/P: DC 9V, 1.11A

Page 4

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

3

Date of Issue: September 10, 2007

TEST METHODOLOGY

3.1 EUT SYSTEM OPERATION
Software Used During the Test
Windows XP
1. EMI test program (file name: EMCTEST) was loaded and
executed in “Windows XP” mode.
2. The detect signal was sent to EUT.
3. Data was sent to the monitor, filling the screen with upper case
of “H” patterns.
Program Sequence
4. Test program sequentially all related I/O’s of Host PC include
EUT and sent “H” patterns to all applicable output ports of
Host PC.
5. Repeat 2 to 4.
Operating System

Remark: Test program is self-repeating throughout the test.

3.2 DECISION OF FINAL TEST MODE
The EUT (model: UKE-100) comes with two types of power adapters (M7-10US08R-A &
M7-10US08R-D) for sale. After the preliminary test, the power adapter with model
M7-10US08R-A was found to emit the worst emissions and therefore had been tested under
operating condition.
1.

The following test mode was scanned during the preliminary test:
Mode 1
Operating

2.

After the preliminary scan, the following test mode was found to produce the highest
emission level.
Mode 1
Then, the EUT configuration and cable configuration of the above highest emission mode
was chosen for all final test items.

Page 5

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

4

Date of Issue: September 10, 2007

INSTRUMENT AND CALIBRATION

4.1 MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been
calibrated once a year or in accordance with the manufacturer's recommendations, and is
traceable to recognized national standards.

4.2 TEST AND MEASUREMENT EQUIPMENT
The following list contains measurement equipment used for testing. The equipment conforms to
the requirement of CISPR 16-1, ANSI C63.2 and other required standards.
Calibration of all test and measurement, including any accessories that may effect such
calibration, is checked frequently to ensure the accuracy. Adjustments are made and correction
factors are applied in accordance with the instructions contained in the respective manual.
Equipment Used for Emission Measurement
Open Area Test Site # 3
Name of Equipment

Manufacturer

Model

Serial Number

Calibration Due

Spectrum Analyzer

Agilnet

E4411B

MY41440314

N.C.R.

Spectrum Analyzer

R&S

FSP30

100112

10/10/2007

EMI Test Receiver

R&S

ESVS30

828488/004

03/12/2008

Pre-Amplifier

Anritsu

MH648A

M18767

08/30/2008

Pre-Amplifier

MITEQ

AFS42-00102650-42-10P-42

966468

04/26/2008

Bilog Antenna

Schwazbeck

VULB9163

144

03/30/2008

Horn Antenna

EMCO

3115

00022250

04/15/2008

Loop Antenna

EMCO

6502

2356

N.C.R.

Turn Table

Chance Most

CM-T003-1

T807-6

N.C.R.

Antenna Tower

Chance Most

CM-A003-1

A807-6

N.C.R.

Controller

CCS

CC-C-1F

N/A

N.C.R.

RF Switch

Anritsu

MP59B

M53867

N.C.R.

Site NSA

CCS

N/A

N/A

05/04/2008

Decoupling Network

FCC

F-201-DCN-5-6MM

34

06/04/2008

Test S/W

LabVIEW 6.1 (CCS OATS EMI SW V2.6)

Remark: The measurement uncertainty is less than +/- 4.0235dB, which is evaluated as per the NAMAS NIS 81 and
CISPR/A/291/CDV.

Page 6

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Powerline Conducted Emissions Test Site
Name of Equipment

Manufacturer

Model

Serial Number

Calibration Due

Rohde & Schwarz

ESHS30

828144/003

10/31/2007

Schaffner

NNB41

03/10013

06/12/2008

LISN 10kHz-100MHz

EMCO

3825/2

9106-1809

04/01/2008

ISN 9kHz-30MHz

FCC

FCC-TLISN-T4

20167

09/15/2007

EMI Test Receiver
9kHz-30MHz
Two-Line V-Network
9kHz-30MHz

Test S/W

LABVIEW (V 6.1)

Remark: The measurement uncertainty is less than +/- 2.81dB, which is evaluated as per the NAMAS NIS 81 and
CISPR/A/291/CDV.

Power Harmonic & Voltage Fluctuation/Flicker Measurement (EN 61000-3-2&-3-3)
Name of Equipment
Manufacturer
Model
Serial Number Calibration Due
Harmonic & Flicker Tester

EMC-Partner

HAR1000-1P

Test S/W

107

05/21/2008

HARCS (Ver. 4.0)

Equipment Used for Immunity Measurement
Name of Equipment
ESD Simulator

ESD Test Site (IEC 61000-4-2)
Manufacturer
Model
Serial Number
NoiseKen

ESS-2001

ESS0210582

Calibration Due
11/15/2007

Radiated Electromagnetic Field Immunity Test Site (IEC 61000-4-3)
Name of Equipment
Manufacturer
Model
Serial Number Calibration Due
Signal Generator
150 Watts 80-1000MHz
Amplifier
30 Watts 0.8-3.0GHz
Amplifier
Power Meter

Agilent

8648C

4108A05772

10/23/2007

Amplifier Research

150W1000M3

306730

N.C.R.

Amplifier Research

30S1G3M1

306722

N.C.R.

Boonton

4232A-01-02

98601

10/25/2007

Power Sensor
Power Sensor

Boonton
Boonton

51011-EMC
51011-EMC

32920
32863

10/25/2007
10/25/2007

Log-Periodic Antenna
Microwave Horn Antenna

Amplifier Research
Amplifier Research

AT1080
AT4002A

306709
306750

N.C.R.
N.C.R.

RF Test System Controller

Amplifier Research

SC1000M3

306666

N.C.R.

Field Probe
0.8-4.2GHz

Amplifier Research
Amplifier Research

FP6001
DC7144A

305657
N/A

04/17/2008
N.C.R.

80-1000MHz
Antenna Tower

Amplifier Research
Amplifier Research

DC6180A
TP2000

N/A
N/A

N.C.R.
N.C.R.

Probe Stand

Amplifier Research

PS2000

N/A

N.C.R.

Test S/W

SW1005 (Release 1.4)

Page 7

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Name of Equipment
ECAT Control Center
Capacitor Clamp

Fast Transients/Burst Test Site (IEC 61000-4-4)
Manufacturer
Model
Serial Number
KeyTek
KeyTek

Test S/W

Name of Equipment

Date of Issue: September 10, 2007

E-Class Series 100
CCL-4

9502325
9503290

Calibration Due
03/08/2008
N.C.R.

E400 Burstware (V4.19 (c))

Surge Immunity Test Site (IEC 61000-4-5)
Manufacturer
Model
Serial Number

Calibration Due

ECAT Control Center

KeyTek

E-Class Series 100

9502325

03/08/2008

External Coupler / Decoupler For
Telecom Lines

KeyTek

CM-TELCD

0104399

N.C.R.

KeyTek

CM-I / OCD

0103234

N.C.R.

I/O Signal Line Coupler /
Decoupler
Test S/W

E500 Surgeware (V4.19cc)

CS Test Site (IEC 61000-4-6)
Name of Equipment

Manufacturer

Model

Serial Number

Calibration Due

Signal Generator

Agilent

8648C

4108A05773

09/19/2007

75 Watts 10kHz-250MHz
Amplifier

Amplifier Research

75A250AM1

306334

N.C.R.

Power Meter

Boonton

4232A-01-02

98501

09/15/2007

Power Sensor

Boonton

51011-EMC

32862

09/15/2007

Power Sensor

Boonton

51011-EMC

32864

09/15/2007

FCC-801-M2-16A

03026

09/15/2007

FCC-801-M3-16A

03027

09/15/2007

FCC-801-T2

03016

09/15/2007

FCC-801-T4

03017

09/15/2007

F-203I-23mm

421

09/15/2007

FCC-801-150-50-CDN

03053&03054

09/15/2007

F-203I-CF-23mm

408

09/15/2007

FCC-801-T8-RJ45

04024

09/15/2007

Power Line Coupling
Decoupling Network
Power Line Coupling
Decoupling Network
Signal Line Coupling
Decoupling Network
Signal Line Coupling
Decoupling Network

Fischer Custom
Communications, Inc.
Fischer Custom
Communications, Inc.
Fischer Custom
Communications, Inc.
Fischer Custom
Communications, Inc.
Fischer Custom
EM Injection Clamp
Communications, Inc.
Fischer Custom
Passive Impedance Adapters
Communications, Inc.
Fischer Custom
Calibration Fixture
Communications, Inc.
Signal Line Coupling
Fischer Custom
Decoupling Network
Communications, Inc.
Attenuator

Amplifier Research

HFP-575-3/6-NM

NF201875106

N.C.R.

Coupler

Amplifier Research

DC2600A

306621

N.C.R.

Test S/W

SW1005 (Release 1.4)

Page 8

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Power Frequency Magnetic Field Immunity Test Site (IEC 61000-4-8)
Name of Equipment
Manufacturer
Model
Serial Number Calibration Due
Magnetic Field Tester
Frequency Converter

Haefely Trench
Extech Electronics

MAG100.1
CFC-105

081436-02
810390

N.C.R.
N.C.R.

Digital Multimeter
EMF Tester
Electromagnetic Field

DHA

CM-312A

ET93C-06-208-01

05/31/2008

TES

1390

020401598

05/17/2008

Voltage Dips/Short Interruption and Voltage Variation Immunity Test Site (IEC 61000-4-11)
Name of Equipment
Manufacturer
Model
Serial Number Calibration Due
Dips/Interruption and
Variations Simulator
Test S/W

Haefely Trench

PLINE 1610

081568-06

08/06/2008

WinPATS (V. 3.26)

Page 9

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

5

Date of Issue: September 10, 2007

FACILITIES AND ACCREDITATIONS

5.1 FACILITIES
All measurement facilities used to collect the measurement data are located at
No.199, Chunghsen Road, Hsintien City, Taipei Hsien, Taiwan, R.O.C.
Tel: 886-2-2217-0894 / Fax: 886-2-2217-1029
No.11, Wugong 6th Rd., Wugu Industrial Park, Taipei Hsien 248, Taiwan
Tel: 886-2-2299-9720 / Fax: 886-2-2298-4045
No.81-1, Lane 210, Bade 2nd Rd., Luchu Hsiang, Taoyuan Hsien 338, Taiwan
Tel: 886-3-324-0332 / Fax: 886-3-324-5235
The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and
CISPR Publication 22.

Page 10

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

5.2 LABORATORY ACCREDITATIONS AND LISTINGS
The test facilities used to perform Electromagnetic compatibility tests are registered or
accredited by the organizations listed in the following table which includes the recognized scope
specifically.
Country Agency

Scope of Accreditation

USA

A2LA

EN 55011, EN 55014-1/2, CISPR 11, CISPR 14-1/2,
EN 55022, EN 55015, CISPR 22, CISPR 15,
AS/NZS 3548, VCCI V3 (2001), CFR 47, FCC Part 15/18,
CNS 13783-1, CNS 13439, CNS 13438, CNS 13803,
CNS 14115, EN 55024, IEC 801-2, IEC 801-3, IEC 801-4,
IEC/EN 61000-3-2, IEC/EN 61000-3-3,
IEC/EN 61000-4-2/3/4/5/6/8/11, EN 50081-1/
EN 61000-6-3, EN 50081-2/EN 61000-6-4,
EN 50081-2/EN 61000-6-1: 2001

USA

FCC

3/10 meter Open Area Test Sites (93105, 90471) /
3M Semi Anechoic Chamber (965860) to perform
FCC Part 15/18 measurements

Japan

VCCI

3/10 meter Open Area Test Sites to perform conducted/radiated
measurements

Logo

93105, 90471
965860

R-393/1066/725/879
C-402/747/912

NEMKO

EN 50081-1/2, EN 50082-1/2, IEC 61000-6-1/2, EN 50091-2,
EN 50130-4, EN 55011, EN 55013, EN 55014-1/2,
EN 55015, EN 55022, EN 55024, EN 61000-3-2/3,
EN 61326-1, IEC 61000-4-2/3/4/5/6/8/11, EN 60601-1-2,
EN 300 328, EN 300 422-2, EN 301 419-1,
EN 301 489-01/03/07/08/09/17, EN 301 419-2/3,
EN 300 454-2, EN 301 357-2

Taiwan

TAF

EN 300 328, EN 300 220-1, EN 300 220-2, EN 300 220-3,
47 CFR FCC Part 15 Subpart C,
EN 61000-3-2, EN 61000-3-3, CNS 13439, CNS 13783-1,
CNS 14115, CNS 13438, AS/NZS CISPR 22, CNS 13022-1,
IEC 61000-4-2/3/4/5/6/8/11, CNS 13022-2/3

Taiwan

BSMI

CNS 13438, CNS 13783-1,
CNS 13439, CNS 14115

SL2-IS-E-0014
SL2-IN-E-0014
SL2-A1-E-0014
SL2-R1-E-0014
SL2-R2-E-0014
SL2-L1-E-0014

Canada

Industry
Canada

3/10 meter Open Area Test Sites (IC 2324C-3, IC 2324C-5) /
3M Semi Anechoic Chamber (IC 6106)

IC 2324C-3
IC 2324C-5
IC 6106

Norway

ELA 124a
ELA 124b
ELA 124c

* No part of this report may be used to claim or imply product endorsement by A2LA or any agency of the US
Government.

Page 11

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

6

Date of Issue: September 10, 2007

SETUP OF EQUIPMENT UNDER TEST

6.1 SETUP DIAGRAM
See test photographs attached in Appendix I for the actual connections between EUT and support
equipment.

6.2 SUPPORT EQUIPMENT
No Equipment

Trade
Name

Model

Serial No.

FCC ID

Data Cable

Power Cord

1.

PC

HP

DX-6120

SGH5330GK7

FCC
DoC

N/A

Unshielded, 1.8m

2.

PC

HP

PL926AV

SGH528048P

FCC
DoC

N/A

Unshielded, 1.8m

3.

CRT Monitor

Samsung

959NF

AQ19H2RT706139P

FCC
DoC

Shielded, 1.8m
with 2 cores
Shielded, 1.8m
with 2 cores

Unshielded, 1.8m
AC I/P:
Unshielded, 1.8m
DC O/P:
Unshielded, 1.8m
with a core
AC I/P:
Unshielded, 1.8m
DC O/P:
Unshielded, 1.8m
with a core
AC I/P:
Unshielded, 1.8m
DC O/P:
Unshielded, 1.8m
with a core

4.

LCD Monitor

Samsung

173P

DI17H4JXB04968Y

FCC
DoC

5.

LCD Monitor

SAMSUNG

959NF

AQ19H2RT706121B

FCC DoC

Shielded, 1.8m
with 2 cores

6.

LCD Monitor

LG

L1740PQ

503KGXA2K858

BEJL17NU

Shielded, 1.8m
with 2 cores

7.

PS/2 Keyboard

Logitech

Y-SJ17

SY528UK

FCC
DoC

Shielded, 1.8m

N/A

8.

PS/2 Keyboard

Logitech

Y-SJ17

SY528UK

FCC
DoC

Shielded, 1.8m

N/A

9.

PS/2 Keyboard

hp

KB-0316

355630-AB1

FCC DoC

Shielded, 1.8m

N/A

10.

PS/2 Keyboard

COMPAQ

KB-0133

N/A

FCC DoC

Shielded, 1.8m

N/A

11.

PS/2 Mouse

Logitech

M-S34

HCA25200400

DZL211029 Shielded, 1.8m

N/A

12.

PS/2 Mouse

Logitech

M-S34

HCA25200475

DZL211029 Shielded, 1.8m

N/A

13.

PS/2 Mouse

Logitech

M-S34

LZC85106992

14.

PS/2 Mouse

Logitech

M-S34

HCA25200251

15.

Printer

EPSON

STYLUS C60

DR3K039633

FCC
DoC

Shielded, 1.8m

Unshielded, 1.8m

16.

Printer

EPSON

STYLUS C60

DR3K041995

FCC
DoC

Shielded, 1.8m

Unshielded, 1.8m

17.

Multimedia
Earphone

Labtec

Axis-301

N/A

FCC
DoC

Unshielded, 1.8m

N/A

18.

Multimedia
Earphone

Ergotech

ET-E220

N/A

FCC
DoC

Unshielded, 1.8m

N/A

19.

Modem

ACEEX

DM-1414

304012269

FCC
DoC

Shielded, 1.8m

N/A

DZL211029 Shielded, 1.8m

N/A

IFAXDM1414 Shielded, 1.8m

Unshielded, 1.8m

Remark: All the above equipment/cables were placed in worse case positions to maximize emission signals during
emission test.
Grounding: Grounding was in accordance with the manufacturer’s requirements and conditions for the intended use.

Page 12

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

7

Date of Issue: September 10, 2007

POWERLINE CONDUCTED & RADIATED EMISSION TEST

7.1 LIMIT
Maximum permissible level of Line Conducted Emission
Frequency
(MHZ)
0.15 - 0.5
0.50 - 5.0
5.0 - 30.0

Class A
(dBuV/m)
Quasi-peak
Average
79
66
73
60
73
60

Class B
(dBuV/m)
Quasi-peak
Average
66 - 56
56 - 46
56
46
60
50

Remark: The lower limit shall apply at the transition frequency.

Maximum permissible level of Common Mode Conducted Emission
(Telecommunication Ports)
CLASS A
Frequency
(MHz)
0.15 - 0.5
0.5 - 30.0

Voltage Limit
(dBuV)
Quasi-peak
Average
97 – 87
84 - 74
87
74

Current Limit
(dBuA)
Quasi-peak
Average
53 – 43
40 – 30
43
30

Remark: The lower limit shall apply at the transition frequency.

CLASS B
Frequency
(MHz)
0.15 - 0.5
0.5 - 30.0

Voltage Limit
(dBuV)
Quasi-peak
Average
84 - 74
74 - 64
74
64

Current Limit
(dBuA)
Quasi-peak
Average
40 – 30
30 – 20
30
20

Remark: 1. The lower limit shall apply at the transition frequency.
2. According to Note 3 on table 4 of EN 55022: 1998 standard, a relaxation of 10 dB over the frequency
range of 6 MHz to 30 MHz is allowed for high-speed services having significant spectral density in this
band. However, this relaxation is restricted to the common mode disturbance converted by the cable from
the wanted signal.

Maximum permissible level of Radiated Emission measured at 10 meter
Frequency
(MHz)
30 – 230
230 - 1000

Class A
(dBuV/m)
Quasi-peak
40
47

Class B
(dBuV/m)
Quasi-peak
30
37

Remark: The lower limit shall apply at the transition frequency.

Page 13

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

7.2 TEST PROCEDURE OF LINE CONDUCTED EMISSION
Procedure of Preliminary Test
The EUT was set up as per the test configuration to simulate typical usage per the user’s manual.
When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is
placed on the ground plane as per EN 55022 (see Test Facility for the dimensions of the ground
plane used). When the EUT is a floor-standing equipment, it is placed on the ground plane which
has a 3-12 mm non-conductive covering to insulate the EUT from the ground plane.
Support equipment, if needed, was placed as per EN 55022.
All I/O cables were positioned to simulate typical actual usage as per EN 55022.
The test equipment EUT installed received AC power, 230VAC/50Hz, through a Line Impedance
Stabilization Network (LISN), which supplied power source and was grounded to the ground
plane.
All support equipments received power from a second LISN.
The EUT test program was started. Emissions were measured on each current carrying line of
the EUT using an EMI Test Receiver connected to the LISN powering the EUT.
The Receiver scanned from 150kHz to 30MHz for emissions in each of the test modes.
During the above scans, the emissions were maximized by cable manipulation.
The test mode(s) described in Item 3.2 were scanned during the preliminary test.
After the preliminary scan, we found the test mode described in Item 3.2 producing the highest
emission level.
The EUT configuration and cable configuration of the above highest emission level were
recorded for reference of the final test.
Procedure of Final Test
EUT and support equipment were set up on the test bench as per the configuration with highest
emission level in the preliminary test.
A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest
emissions. Emission frequency and amplitude were recorded into a computer in which
correction factors were used to calculate the emission level and compare reading to the
applicable limit.
The test data of the worst-case condition(s) was recorded.

Page 14

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

7.3 TEST PROCEDURE OF COMMON MODE CONDUCTED
EMISSION FOR TELECOMMUNICATION PORT
Selecting ISN for unscreened cable or a current probe for screened cable to take measurement.
The port of the EUT was connected to the remote side support equipment through the
ISN/Current Probe and communication in normal condition.
Making a overall range scan by using the test receiver controlled by controller and record at least
six highest emissions for showing in the test report.
Emission frequency and amplitude were recorded into a computer in which correction factors
were used to calculate the emission level and compare reading to the applicable limit.
In case of measuring on the screened cable, the current limit shall be applied, otherwise the
voltage limit should be applied.
The following test mode was scanned during the preliminary test:
Not applicable, because EUT has no LAN port or modem port.

Page 15

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

7.4 TEST PROCEDURE OF RADIATED EMISSION
Procedure of Preliminary Test
The equipment was set up as per the test configuration to simulate typical usage per the user’s
manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8 meters is
used which is placed on the ground plane. When the EUT is a floor-standing equipment, it is
placed on the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT
from the ground plane.
Support equipment, if needed, was placed as per EN 55022.
All I/O cables were positioned to simulate typical usage as per EN 55022.
The EUT received AC power source, 230VAC/50Hz, from the outlet socket under the turntable.
All support equipments received power from another socket under the turntable.
The antenna was placed at 10 meter away from the EUT as stated in EN 55022. The antenna
connected to the Spectrum Analyzer via a cable and at times a pre-amplifier would be used.
The Analyzer / Receiver quickly scanned from 30MHz to 1000MHz. The EUT test program was
started. Emissions were scanned and measured rotating the EUT to 360 degrees and positioning
the antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal
polarization, to maximize the emission reading level.
The test mode(s) described in Item 3.2 were scanned during the preliminary test:
After the preliminary scan, we found the test mode described in Item 3.2 producing the highest
emission level.
The EUT and cable configuration, antenna position, polarization and turntable position of the
above highest emission level were recorded for the final test.
Procedure of Final Test
EUT and support equipment were set up on the turntable as per the configuration with highest
emission level in the preliminary test.
The Analyzer / Receiver scanned from 30MHz to 1000MHz. Emissions were scanned and
measured rotating the EUT to 360 degrees, varying cable placement and positioning the antenna
1 to 4 meters above the ground plane, in both the vertical and the horizontal polarization, to
maximize the emission reading level.
Recorded at least the six highest emissions. Emission frequency, amplitude, antenna position,
polarization and turntable position were recorded into a computer in which correction factors
were used to calculate the emission level and compare reading to the applicable limit and only
Q.P. reading is presented.
The test data of the worst-case condition(s) was recorded.

Page 16

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

7.5 TEST RESULTS
Powerline Conducted Emission
Operation Mode: Mode 1
Temperature:

25oC

Tested by:

Eric Cheng

Test Date:

August 10, 2007

Humidity:

55% RH

Freq.
(MHz)

QP
Reading
(dBuV)

AV
Reading
(dBuV)

Corr.
factor
(dB)

QP
Result
(dBuV)

AV
Result
(dBuV)

QP
Limit
(dBuV)

AV
Limit
(dBuV)

QP
Margin
(dB)

AV
Margin Note
(dB)

0.160

51.270

48.700

0.180

51.450

48.880

65.464

55.464

-14.014

-6.584

L1

0.213

48.090

45.700

0.100

48.190

45.800

63.088

53.088

-14.898

-7.288

L1

0.372

44.960

41.710

0.100

45.060

41.810

58.456

48.456

-13.396

-6.646

L1

0.532

46.610

43.640

0.100

46.710

43.740

56.000

46.000

-9.290

-2.260

L1

9.453

43.860

39.010

0.645

44.505

39.655

60.000

50.000

-15.495

-10.345

L1

11.175

38.100

34.560

0.724

38.824

35.284

60.000

50.000

-21.176

-14.716

L1

0.156

46.640

42.520

0.188

46.828

42.708

65.674

55.674

-18.846

-12.966

L2

0.213

45.410

42.520

0.100

45.510

42.620

63.088

53.088

-17.578

-10.468

L2

0.266

40.950

38.560

0.100

41.050

38.660

61.242

51.242

-20.192

-12.582

L2

0.532

44.590

43.700

0.100

44.690

43.800

56.000

46.000

-11.310

-2.200

L2

9.230

34.440

29.670

0.623

35.063

30.293

60.000

50.000

-24.937

-19.707

L2

11.086

31.470

26.960

0.722

32.192

27.682

60.000

50.000

-27.808

-22.318

L2

Remark:
1.

Measuring frequencies from 0.15 MHz to 30MHz.

2.

The emissions measured in frequency range from 0.15 MHz to 30MHz were made with
an instrument using Quasi-peak detector and average detector.

3.

The IF bandwidth of SPA between 0.15MHz and 30MHz was 10kHz; the IF bandwidth
of Test Receiver between 0.15MHz and 30MHz was 9kHz;

4.

L1 = Line One (Live Line) / L2 = Line Two (Neutral Line)

Page 17

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Test Plots
Conducted emissions (Line 1)

Conducted emissions (Line 2)

Page 18

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Radiated Emission
Operation Mode: Mode 1

Test Date: August 13, 2007

o

Temperature:

26 C

Tested by: Eric Cheng

Humidity:

55% RH

Polarity:

Ver. / Hor.

Frequency
(MHz)

Ant. Pol.
(H/V)

Detector
Mode
(PK/QP)

Reading
(dBuV)

Correction Factor
(dB/m)

Result
(dBuV/m)

Limit 10m
(dBuV/m)

Margin
(dB)

59.10

V

QP

9.50

12.99

22.49

30.00

-7.51

141.55

V

QP

10.50

9.32

19.82

30.00

-10.18

163.38

V

QP

8.80

10.22

19.02

30.00

-10.98

253.10

V

QP

6.40

14.38

20.78

37.00

-16.22

536.83

V

QP

6.20

20.90

27.10

37.00

-9.90

648.37

V

QP

5.80

22.74

28.54

37.00

-8.46

55.27

H

QP

10.10

13.20

23.30

30.00

-6.70

134.27

H

QP

15.50

9.79

25.29

30.00

-4.71

182.78

H

QP

8.10

11.33

19.43

30.00

-10.57

253.10

H

QP

12.00

14.38

26.38

37.00

-10.62

612.00

H

QP

6.40

22.38

28.78

37.00

-8.22

752.65

H

QP

4.90

23.59

28.49

37.00

-8.51

Remark:
1.

Measuring frequencies from 30MHz to 1GHz.

2.

Radiated emissions measured in frequency range from 30MHz to 1000MHz were made
with an instrument using Peak /Quasi-peak detector mode.

3.

Measurements above show only up to 6 maximum emissions noted, or would be lesser,
with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie:
margin>20dB from the applicable limit) and considered that's already beyond the
background noise floor.

4.

The IF bandwidth of SPA between 30MHz and 1GHz was 100 kHz.

Page 19

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

8

Date of Issue: September 10, 2007

POWER HARMONICS TEST
Port

: AC mains

Basic Standard

: EN 61000-3-2

Limits

:

Tested by

: Eric Cheng

Temperature

: 25oC

Humidity

: 55% RH

CLASS A;

CLASS B;

CLASS C;

CLASS D

Limit:
Limits for Class A equipment

Limits for Class D equipment

Harmonics

Max. permissible

Harmonics

Order

harmonics current

Order

n

A

n

Max. permissible harmonics
current per watt mA/W

Odd harmonics

Max. permissible
harmonics current
A

Odd harmonics only

3

2.30

3

3.4

2.30

5

1.14

5

1.9

1.14

7

0.77

7

1.0

0.77

9

0.40

9

0.5

0.40

11

0.33

11

0.35

0.33

13

0.21

13

0.30

0.21

15<=n<=39

3.85/n

0.15x15/n

15<=n<=39 0.15x15/n
Even harmonics
2

1.08

4

0.43

6

0.30

8<=n<=40

0.23x8/n

Page 20

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Block Diagram of Test Setup:

Harmonics & Flicker
Analyzer
+
Power Source

Power Cord

EUT

Support Units

0.8m

Test Procedure:
a.

b.

The EUT was placed on the top of a wooden table 0.8 meters above the ground and
operated to produce the maximum harmonic components under normal operating conditions
for each successive harmonic component in turn.
The correspondent test program of test instrument to measure the current harmonics
emanated from EUT is chosen. The measure time shall be not less than the time necessary
for the EUT to be exercised.

Test Result:
No non-compliance noted.

Page 21

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Harmonic Emission - IEC 61000-3-2 , EN 61000-3-2 , (EN60555-2)
Cat5 KVM Extender
UKE-100
Eric Cheng
Remarks

Full Bar

Temp : 25'C

Humidity : 55% RH

: Actual Values

Empty Bar : Maximum Values
Blue : Current , Green : Voltage , Red : Failed

According to EN 61000-3-2, for the following categories of equipment, limits are not specified
in this standard:
Remark:
1.

Limits may be defined in a future amendment or revision of the standard. Equipment with a
rated power of 75W or less, other than lighting equipment.

2.

This value may be reduced from 75W to 50W in the future, subject to approval by National
Committees at that time.

Page 22

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

9

Date of Issue: September 10, 2007

POWER VOLTAGE FLUCTUATION / FLICKER TEST
Port

: AC mains

Basic Standard

: EN 61000-3-3

Limits

: §5 of EN 61000-3-3

Tested by

: Eric Cheng

Temperature

: 25oC

Humidity

: 55% RH

Limit:
TEST ITEM

LIMIT

REMARK

Pst

1.0

Pst means short-term flicker indicator.

Plt

0.65

Plt means long-term flicker indicator.

Tdt (ms)

500

Tdt means maximum time that dt exceeds 3 %.

dmax (%)

4%

dmax means maximum relative voltage change.

dc (%)

3.3%

dc means relative steady-state voltage change

Block Diagram of Test Setup:
Harmonics & Flicker
Analyzer
+
Power Source

Power
Cord
EUT

Support Units

0.8m

Page 23

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Test Procedure:
a.

The EUT was placed on the top of a wooden table 0.8 meters above the ground and
operated to produce the most unfavorable sequence of voltage changes under normal
operating conditions.

b.

During the flick measurement, the measure time shall include that part of whole operation
cycle in which the EUT produce the most unfavorable sequence of voltage changes. The
observation period for short-term flicker indicator is 10 minutes and the observation period
for long-term flicker indicator is 2 hours.

Test Result:
No non-compliance noted.

Page 24

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Measurement

Date : 2007/8/10 PM 09:22:1 V4.15
File :
Cat5 KVM Extender
UKE-100
Eric Cheng
Remarks

Temp : 25'C

Humidity : 55% RH

Urms =

229.9V

Freq =

49.948

Range:

0.5 A

Irms =

0.043A

Ipk

0.240A

cf

=

5.528

P

3.939W

S

9.991VA pf

=

0.394

=

Test - Time :

=
=

1 x 10min = 10min ( 100 %)

LIN (Line Impedance Network) :
Limits :

Plt

:

L: 0.24ohm +j0.15ohm N: 0.16ohm +j0.10ohm

0.65

Pst

:

1.00

dmax :

4.00 %

dc

:

3.30 %

dtLim:

3.30 %

dt>Lim:

500ms

P3s

P1s

Test completed, Result: PASSED
Plt

=

0.076
Pst

P50s

P10s

P0.1s

Fli

dmax

dc

[%]

[%]

0.000

0.000

dt>Lim
[ms]
1

0.076

0.010

0.010

0.011

0.015

0.021

0.002

0.000

Page 25

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

10 ELECTROSTATIC DISCHARGE (ESD) IMMUNITY TEST
Port

: Enclosure

Basic Standard

: IEC 61000-4-2

Test Level

: ± 8 kV (Air Discharge)
± 4 kV (Contact Discharge)
± 4 kV (Indirect Discharge)

Performance Criterion : B (Standard Required)
Tested by

: Eric Cheng

Temperature

: 25oC

Humidity

: 55% RH

Pressure

: 1005mbar

Block Diagram of Test Setup:
(The 470 k ohm resistors are installed per standard requirement.)

VCP
EUT & its
direct
Support Units

Indirect
Support units

HCP

>1m

Wooden Table

0.8m

Ground Reference Plane

Page 26

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Test Procedure:
1. The EUT was located 0.1 m minimum from all side of the HCP.
2. The indirect support units were located 1 m minimum away from the EUT, but direct support
unit was/were located at same location as EUT on the HCP and keep at a distance of 10 cm
with EUT.
3. A scroll ‘H’ test program was loaded and executed in Windows XP mode.
4. The EUT sent above message to LCD monitor and related peripherals through the test.
5. Active the communication function if the EUT with such port(s).
6. As per the requirement of EN 55024; applying direct contact discharge at the sides other than
front of EUT at minimum 50 discharges (25 positive and 25 negative) if applicable, can’t be
applied direct contact discharge side of EUT then the indirect discharge shall be applied. One of
the test points shall be subjected to at least 50 indirect discharge (contact) to the front edge of
horizontal coupling plane.
7. Other parts of EUT where it is not possible to perform contact discharge then selecting
appropriate points of EUT for air discharge, a minimum of 10 single air discharges shall be
applied.
8. The application of ESD to the contact of open connectors is not required.
9. The EUT direct connection units also need to be applied ESD at the port of EUT cable
connected.
10. To simulate a single ESD event (either by air or by contact discharge), the charge on the EUT
shall be removed prior to each applied ESD pulse. The charge on the metallic point or part to
which the ESD pulse is to be applied, for example, connector shells, battery charge pins,
metallic antennae, shall be removed prior to each applied ESD test pulse. When one or several
metallic accessible parts are subject to the ESD test, the charge shall be removed from the point
where the ESD pulse is to be applied, as no guarantee can be given about the resistance
between this and other accessible points on the product.
11. Putting a mark on EUT to show tested points. The following test condition was followed during
the tests.
Remark: As per IEC 61000-4-2, two 470k bleed resistors cable is connected between the EUT and HCP during the
test applicable for power ungrounded or battery operating unit only.

The electrostatic discharges were applied as follows:
Amount of discharge

Voltage

Coupling

Min. 20 / Point
Min. 50 / Point
Min. 50 / Point
Min. 50 / Point
Min. 50 / Point
Min. 50 / Point

± 8 kV
± 4 kV
± 4 kV
± 4 kV
± 4 kV
± 4 kV

Air Discharge
Contact Discharge
Indirect Discharge HCP (Front)
Indirect Discharge VCP (Right)
Indirect Discharge VCP (Left)
Indirect Discharge VCP (Back)

Test Result
(Criterion)
A
A
A
A
A
A

Remark: For tested points to EUT, refer to the enclosed pages. Be aware that the Blue mark is for contact
discharge, and the red mark is for air discharge.

Page 27

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Performance & Result:
Criteria A:

The apparatus continues to operate as intended. No degradation of
performance or loss of function is allowed below a performance level
specified by the manufacturer, when the apparatus is used as intended.
In some cases the performance level may be replaced by a permissible
loss of performance.

Criteria B:

The apparatus continues to operate as intended after the test. No
degradation of performance or loss of function is allowed below a
performance level specified by the manufacturer, when the apparatus is
used as intended. In some cases the performance level may be replaced
by a permissible loss of performance. During the test, degradation of
performance is however allowed.

Criteria C:

Temporary loss of function is allowed, provided the functions self
recoverable or can be restored by the operation of controls.

PASS

FAIL

Observation: No function degraded during the tests.

Page 28

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

The Tested Points of EUT

Page 29

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Page 30

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Page 31

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

11 RADIATED ELECTROMAGNETIC FIELD IMMUNITY TEST
Port

: Enclosure

Basic Standard

: IEC 61000-4-3

Requirements

: 3 V/m / with 80% AM. 1 kHz Modulation.

Performance Criterion : A (Standard Required)
Tested by

: Eric Cheng

Temperature

: 25oC

Humidity

: 55% RH

Pressure

: 1005mbar

Block Diagram of Test Setup:

3 meter

7x3x3

EUT & Support
Units

1.5 meter
0.8m

Power Amp

PC Controller to
control S.G. & PA as
well as forward power

Signal
Generator

EUT Monitoring by using
a camera

Control Room

Page 32

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Test Procedure:
1. The EUT was located at the edge of supporting table keep 3 meter away from transmitting
antenna, it just the calibrated square area of field uniformity. The support units were located
outside of the uniformity area, but the cable(s) connected with EUT were exposed to the
calibrated field as per IEC 61000-4-3.
2. Setting the testing parameters of RS test software per IEC 61000-4-3.
3. Performing the pre-test at each side of with double specified level (6V/m) at 4% steps.
4. From the result of pre-test in step 5, choice the worst side of EUT for final test from 80 MHz
to 1000 MHz at 1% steps.
5. Recording the test result in following table.
Preliminary test conditions:
Test level
Steps
Dwell Time

: 6V/m
: 4 % of fundamental
: 3 sec

Freq. Range
(MHz)

Field

Modulation

Polarity

Position

Test Result
(Criterion)

80-1000

6V/m

Yes

H

Front

A

80-1000

6V/m

Yes

V

Front

A

80-1000

6V/m

Yes

H

Right

A

80-1000

6V/m

Yes

V

Right

A

80-1000

6V/m

Yes

H

Back

A

80-1000

6V/m

Yes

V

Back

A

80-1000

6V/m

Yes

H

Left

A

80-1000

6V/m

Yes

V

Left

A

Final test conditions:
Test level
Steps
Dwell Time

: 3V/m
: 1 % of fundamental
: 3 sec

Freq. Range
(MHz)

Field

Modulation

Polarity

Position

Test Result
(Criterion)

80-1000

3V/m

Yes

H

Front

A

80-1000

3V/m

Yes

V

Front

A

Page 33

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Performance & Result:
Criteria A:

The apparatus continues to operate as intended. No degradation of
performance or loss of function is allowed below a performance level
specified by the manufacturer, when the apparatus is used as intended.
In some cases the performance level may be replaced by a permissible
loss of performance.

Criteria B:

The apparatus continues to operate as intended after the test. No
degradation of performance or loss of function is allowed below a
performance level specified by the manufacturer, when the apparatus is
used as intended. In some cases the performance level may be replaced
by a permissible loss of performance. During the test, degradation of
performance is however allowed.

Criteria C:

Temporary loss of function is allowed, provided the functions self
recoverable or can be restored by the operation of controls.

PASS

FAIL

Observation: No function degraded during the tests.

Page 34

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

12 FAST TRANSIENTS/BURST IMMUNITY TEST
Port

: On Power Supply Lines and Data Line

Basic Standard

: IEC 61000-4-4

Requirements

: ± 1 kV for Power Supply Line

Performance Criterion : B (Standard Required)
Tested by

: Eric Cheng

Temperature

: 25oC

Humidity

: 55% RH

Pressure

: 1005mbar

Block Diagram of Test Setup:
EUT
AC Line

EFT/Burst/
Surge Generator

Controller Computer

Support Units

10cm

Ground Reference Plane

Non-Conductive Table

Comm. Line ≧ 3 m
To Load
10cm

EUT

AC Line
Burst Generator

10cm

Injection Clamp

Ground Reference Plane

Page 35

Non-Conductive Table

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Test Procedure:
1.
2.
3.
4.
5.

The EUT and support units were located on a wooden table 0.1 m away from ground
reference plane.
A 0.5m long power cord was attached to EUT during the test.
The length of communication cable between communication port and clamp was keeping
within 0.5m.
Injected test voltage to the EUT ports from minimum to standard request or client request.
Recording the test result as shown in following table.

Test conditions:
Impulse Frequency : 5kHz
Tr/Th
: 5/50ns
Burst Duration
: 15ms
Burst Period
: 3Hz
Inject Line

Voltage kV

Inject Method

Line
Neutral
PE
Line + Neutral
L + PE
N + PE
L + N + PE
RJ45 port (LAN cable)
RJ11 port (Line cable)

±1
±1
±1
±1
±1
±1
±1
±0.5
±0.5

Direct
Direct
Direct
Direct
Direct
Direct
Direct
Clamp
Clamp

Page 36

Test Result
(Criterion)
A
A
N/A
A
N/A
N/A
N/A
N/A
N/A

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Performance & Result:
Criteria A:

The apparatus continues to operate as intended. No degradation of
performance or loss of function is allowed below a performance level
specified by the manufacturer, when the apparatus is used as intended.
In some cases the performance level may be replaced by a permissible
loss of performance.

Criteria B:

The apparatus continues to operate as intended after the test. No
degradation of performance or loss of function is allowed below a
performance level specified by the manufacturer, when the apparatus is
used as intended. In some cases the performance level may be replaced
by a permissible loss of performance. During the test, degradation of
performance is however allowed.

Criteria C:

Temporary loss of function is allowed, provided the functions self
recoverable or can be restored by the operation of controls.

PASS

FAIL

Observation: No function degraded during the tests.

Page 37

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

13 SURGE IMMUNITY TEST
Port

: Power Cord

Basic Standard

: IEC 61000-4-5

Requirements

: ± 1 kV (Line to Line)

Performance Criterion : B (Standard Required)
Tested by

: Eric Cheng

Temperature

: 25oC

Humidity

: 55% RH

Pressure

: 1005mbar

Block Diagram of Test Setup:
To AC
Source

Surge Immunity
Test

EUT
&
Support Units

0.8m

Controller Computer

Test Procedure:
1. The EUT and support units were located on a wooden table 0.8 m away from ground floor.
2. Injected test voltage to the EUT ports from minimum to standard request or client request.
3. Recording the test result as shown in following table.

Page 38

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Test conditions:
Voltage Waveform
Current Waveform
Polarity
Phase angle
Number of Test

:
:
:
:
:

1.2/50 us
8/20 us
Positive/Negative
0o, 90o, 270o
5

Coupling Line
Line + Neutral
L + PE
N + PE
T, R-Ground
L1, 2, 3, 4-G

Voltage
(kV)
1
2
2
1
1

Coupling
Method
Capacitive
Capacitive
Capacitive
Capacitive
Capacitive

Polarity
Pos./ Neg.
Pos./ Neg.
Pos./ Neg.
Pos./ Neg.
Pos./ Neg.

Test Result
(Criterion)
A
N/A
N/A
N/A
N/A

Performance & Result:
Criteria A:

The apparatus continues to operate as intended. No degradation of
performance or loss of function is allowed below a performance level
specified by the manufacturer, when the apparatus is used as intended.
In some cases the performance level may be replaced by a permissible
loss of performance.

Criteria B:

The apparatus continues to operate as intended after the test. No
degradation of performance or loss of function is allowed below a
performance level specified by the manufacturer, when the apparatus is
used as intended. In some cases the performance level may be replaced
by a permissible loss of performance. During the test, degradation of
performance is however allowed.

Criteria C:

Temporary loss of function is allowed, provided the functions self
recoverable or can be restored by the operation of controls.

PASS

FAIL

Observation: No function degraded during the tests.

Page 39

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

14 CONDUCTED DISTRBANCE/INDUCED RADIO-FREQUENCY
FIELD IMMUNITY TEST
Port

: AC Port and Data Line

Basic Standard

: IEC 61000-4-6

Requirements

: 3 V with 80% AM. 1 kHz Modulation.

Injection Method

: CDN-M2 for Power Cord

Performance Criterion : A (Standard Required)
Tested by

: Eric Cheng

Temperature

: 25oC

Humidity

: 55% RH

Pressure

: 1005mbar

Block Diagram of Test Setup:
Side View:
0.1m< L <0.3m
10 cm isolation
supporter
EUT and
Support units

Power
Amplifier

CDN

PC
Controller

Ground Reference Plane

0.1m95
70
30
25
C

Voltage
Dips

Voltage
Interruptions

Test Level
% UT
<5

Test Interval

: Min. 10 sec.

Tested by

: Eric Cheng

Temperature

: 25oC

Humidity

: 55% RH

Pressure

: 1005mbar

Reduction
(%)
>95

Duration
( periods )
250

Performance
Criteria
C

Block Diagram of Test Setup:
To AC
Source

Dips/Interruption
and Variations
Simulator

EUT
&
Support Units

0.8m

Controller Computer

Test Procedure:
1.
2.
3.
4.

The EUT and support units were located on a wooden table, 0.8 m away from ground floor.
Setting the parameter of tests and then Perform the test software of test simulator.
Conditions changes to occur at 0 degree crossover point of the voltage waveform.
Recording the test result in test record form.

Page 44

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

Test conditions
The duration with a sequence of three dips/interruptions with interval of 10 s minimum (Between
each test event )
Voltage Dips:
Test Level
% UT

Reduction
(%)

Duration
(periods)

Observation

Meet
Performance
Criteria

0

100

0.5

Normal

A

70

30

25

Normal

A

Duration
(periods)

Observation

Meet
Performance
Criteria

250

EUT shut down, but can
be recovered manually as
the events disappeared.

C

Voltage Interruptions:
Test Level
% UT
0

Reduction
(%)
100

Performance & Result:
Criteria A:

The apparatus continues to operate as intended. No degradation of
performance or loss of function is allowed below a performance level
specified by the manufacturer, when the apparatus is used as intended.
In some cases the performance level may be replaced by a permissible
loss of performance.

Criteria B:

The apparatus continues to operate as intended after the test. No
degradation of performance or loss of function is allowed below a
performance level specified by the manufacturer, when the apparatus is
used as intended. In some cases the performance level may be replaced
by a permissible loss of performance. During the test, degradation of
performance is however allowed.

Criteria C:

Temporary loss of function is allowed, provided the functions self
recoverable or can be restored by the operation of controls.

PASS

FAIL

Page 45

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

APPENDIX I –
PHOTOGRAPHS OF TEST SETUP
POWERLINE CONDUCTED EMISSION TEST (EN 55022)

Page 46

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

RADIATED EMISSION TEST (EN 55022)

Page 47

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

POWER HARMONIC & VOLTAGE FLUCTUATION / FLICKER TEST
(EN 61000-3-2/EN 61000-3-3)

Page 48

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

ELECTROSTATIC DISCHARGE TEST (IEC 61000-4-2)

RADIATED ELECTROMAGNETIC FIELD TEST (IEC 61000-4-3)

Page 49

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

FAST TRANSIENTS/BURST TEST (IEC 61000-4-4)

SURGE IMMUNITY TEST (IEC 61000-4-5)

Page 50

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

CONDUCTED DISTURBANCE, INDUCED BY RADIO-FREQUENCY
FIELDS TEST (IEC 61000-4-6)

POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST (IEC
61000-4-8)

Page 51

Rev. 00

Compliance Certification Services Inc.
Report No.: 70509004-E

Date of Issue: September 10, 2007

VOLTAGE DIPS / INTERRUPTION TEST (IEC 61000-4-11)

Page 52

Rev. 00



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Create Date                     : 2007:09:11 05:05:03Z
Modify Date                     : 2007:09:11 13:07:23+08:00
Page Count                      : 52
Creation Date                   : 2007:09:11 05:05:03Z
Mod Date                        : 2007:09:11 13:07:23+08:00
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : gina_lo
Metadata Date                   : 2007:09:11 13:07:23+08:00
Creator                         : gina_lo
Title                           : Microsoft Word - 70509004-E EN 55022 and EN55024.doc
EXIF Metadata provided by EXIF.tools

Navigation menu