Specified Technologies Inc. (STI) is an industry leader solely committed to the development of innovative and reliable firestop solutions to stop the spread of fire,
smoke and toxic gasses.
For over 20 years, STI has worked hand-in-hand with the construction industry
to create modern firestop solutions for all types of new construction and retrofit
applications. Considering the increasing complexity of new building constructions,
this is no small task. All of our systems are tested and certified by accredited laboratories
all over the world, and we offer the broadest range of UL Classified Systems, more than any other firestop manufacturer. STI develops and manufactures innovative and reliable firestop solutions for a very
wide range of penetrations and joint applications.
STI takes steps to minimize or eliminate volatile organic compounds (VOCs) and our products meet or
exceed the standards for sustainable design requirements and LEED® credits.

.	

Summary of Contents

Firestopping Overview
Elements of Fire Protection.................................................................................................. Page 4
Passive Fire Protection - Firestopping................................................................................. Page 4
Worldwide Standards........................................................................................................... Page 5

Products and Applications
Application Selector............................................................................................................. Page 6
Product Information............................................................................................................. Page 8

EZ-Path® Fire Rated Pathway
Features and Benefits.......................................................................................................... Page 20
Ordering Information............................................................................................................ Page 23

2

	

A Few STI References...
Institutions

Industrial / Infrastructure

High Rise Buildings

Healthcare Facilities

KAUST – Jeddah

Substations – Qatar

Emirates Towers- Dubai

Mayo Clinic - USA

PNUW – Riyadh

Nestle – Russia

Shams Towers- Abu Dhabi

Cleveland Clinic- USA

Al Ain University – Al Ain

Rolex – Switzerland

Etihad Towers- Abu Dhabi

Al Saad Hospital- KSA

CEA center – Paris

Charles de Gaulle Airport – Paris

KAFD- Riyadh

Saudi German Hospital- KSA

Palexpo – Switzerland

Genève Airport – Switzerland

Silhouette tower- Doha

Hôpitaux Universitaire de Genève

Harvard University – USA

SNCB – Belgium

10 Kings Road-Jeddah

Sanofi Aventis - Mexico

Johns Hopkins University – USA

Unilever DataCenter – UK

Jabal Al Kaaba- Mecca

Hôpitaux Universitaire de Reins- France

New York University – USA

Singtel Datacenter – Singapore

Rose Rotana Suites -Dubai

US Air Force Medical Command- USA

Crédit Suisse – Zurich

Télévision Suisse Romande – Switzerland

Rotana Khalidiya Palace- Abu Dhabi

King Hamad Hospital- Bahrain

Caserne de pompier – Genève

EUROCONTROL – Belgium

Central Market-Abu Dhabi

Stanford University Medical Center – USA

Argonne National
Laboratories
Argonne, IL
AT&T Switching Center
The Mayo Clinic
Cleveland Clinic
Rochester, MN
Cleveland, OH

Syncrude
Fort McMurray, Alberta, Canada
Calgary South Medical Center
Calgary, Alberta, Canada
Bellagio Hotel and Casino
Las Vegas, NV
Boeing Aircraft
Renton, WA

Stanford University
Palo Alto, CA

Sabiya Power Plant
Unilever DataCenter Kuwait
UK

Charles de Gaulle Airport P 911 Project (U.S. Naval Base)
Children’s Hospital
Ministry of Electricity and Water
Paris, France
of Philadelphia
National Bank of Bahrain
Philadelphia, PA Children’s Hospital
Boston, MA
Hôpitaux Universitaire de Genève
7 World Trade Center
Genève, Switzerland
Hearst Tower
Al-Saad Hospital
New York, NY
Dammam,
Borgata Hotel and Casino
Saudi Arabia
Atlantic City, NJ

US Army Base Pyungtaek,
PoongLim (Phase I & II)
Korea

ChiMei Semiconductor Project
Quanta Display Project
Taiwan Semiconductor Mfg.
Taiwan

Cabras Power
Beaches Resort – Italian Village Extension
Plant
Turks and Caicos Islands
KAUST
Dubai International Airport
Republic Bank Trinidad
Jeddah,
Emirates Tower, Dubai
Pacific Plaza Towers
Saudi Arabia
Etihad Towers, Abu Dhabi
Malayan Towers
United Arab Emirates
Nextel Switching Stations
Philippines
KAFD
Caracas, Venezuela
Riyadh,
Saudi Arabia
New Social Security
KLCC Towers
Belgo-Mieira (Steel Plant)
Building
Kuala Lumpur
Telemar (Telecom)
Panama
Malaysia
Brazil

Atlanta
Financial
Center
Atlanta, GA

Cal State
Fresno, CA
Air Force Academy
Colorado Springs, CO
Madero Refinery
Shriner’s Hospital
Proctor and Gamble Plant
Mexico

Nextel Switching
Stations – Buenos Aires

3

.	

Elements of Fire Protection

The essential elements of fire protection can be classified as either passive or active fire protection. Used in
conjunction with one another to provide a balanced fire protection strategy in modern construction, both active
and passive fire protection systems are analogous to safety belts and air bags in automobiles.
Active fire protection elements are designed to activate once a fire starts to control growth or extinguish it.
Examples include fire sprinklers or gaseous extinguishing systems. Fire alarms also fall into this category as
they provide notification to building occupants and emergency responders.
Passive fire protection elements are designed to control fire growth and spread through the erection of barriers that
minimize the spread of fire, smoke, and hot gases. Such systems are said to compartmentalize or contain fire to
the point or origin thereby allowing occupants time for safe egress and fire fighting personnel time for safe ingress
to perform search and rescue. Passive fire protection systems may also enhance structural integrity. Examples of
passive fire protection include fire-resistive rated floors and walls, fire-proofing materials for structural elements,
fire doors, and fire dampers. Firestopping is an essential element of an effective passive fire protection system.

.	

Passive Fire Protection - Firestopping

No passive fire protection system is complete without proper firestopping systems. As service elements penetrate
fire-resistive rated walls and floors, unsealed gaps around them will allow the spread of flames, smoke, and gasses
thereby neutralizing the effectiveness of such barriers. Installation of firestopping materials to seal the gaps around
such penetrations restores the integrity of the barriers and maintains hourly fire endurance ratings. The complete
STI line of firestopping products entails all aspects of proper firestopping from simple joints or gaps to single or
multiple penetrant systems such as pipes, cables, cable trays, or ducts.

The construction of barrier
walls and floors to withstand
the passage of fire, smoke
and super-heated gasses.

4

Electrical or mechanical service
lines breach a fire-barrier wall
or floor.

Firestop materials must be
installed to restore an hourly
fire-rating.

Worldwide Standards
North American Standards
ASTM Standards

E84 ................................Test Method for Surface Burning Characteristics of Building Materials
E90.................................Test Method of Airborne Sound Transmission Loss of Building Partitions and Elements
E136...............................Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C
E814...............................Test Method for Fire Tests of Through Penetration Firestops
E119...............................Test Method of Building Construction and Materials
E1399.............................Test Method for Measuring the Minimum and Maximum Joint Widths of Architectural Joint Systems
E1966.............................Test Method for Fire-Resistive Joint Systems
E2307.............................Test Method for Determining Fire Resistance of Perimeter Fire Barrier Systems

UL Standards

UL263............................Fire Test of Building Construction and Materials (equivalent to ASTM E119)
UL1479..........................Fire Tests of Through Penetration Firestops (equivalent to ASTM E814)
UL2079..........................Fire Tests for Fire Resistance of Building Joint Systems

ULC Standards

ULC S101......................Standard Method of Fire Endurance Tests of Building Construction Materials
ULC S102......................Standard Method of Testing for Surface Burning Characteristics of Building Materials & Assemblies
ULC S115......................Standard Method of Fire Tests of Firestop Systems

1366 •
DIN 41

EN Standards

N

6• E
47

European Standards

EN 1366-3.....................Fire Resistance Tests for Service Installations. Penetration Seals.
EN 1366-4 ....................Fire Resistance Tests for Service Installations. Linear Joint Seals.
EN ISO 11925-2............Reaction To Fire Tests. Ignitability of Building Products Subjected to Direct Impingement of Flame
EN 13501-1...................Fire Classification of Construction Products and Building Elements Using Test Data From Reaction
To Fire Tests
EN 13501-2...................Fire Classification of Construction Products and Building Elements Using Data From Fire Resistance 	
Tests, Excluding Ventilation Services
• BS
02

.	

DIN Standards

DIN 4102........................Fire Behavior of Building Materials and Building Components
DIN 4102-1....................Reaction To Fire Tests - Ignitability of Building Products Subjected To Direct Impingement of Flame
DIN 4102-2....................Building Components; Definitions, Requirements and Tests
DIN 4102-6....................Ventilation Ducts; Definitions, Requirements and Tests
DIN 4102-9....................Seals for Cable Penetrations; Concepts, Requirements and Testing
DIN 4102-11..................Pipe Encasements, Pipe Bushings, Service Shafts and Ducts, and Barriers Across Inspection
Openings; Terminology, Requirements and Testing

British Standards

BS476-20......................Fire Tests on Building Materials and Structures. Part 20: Method for Determination of the Fire
Resistance of Elements of Construction (General Principles)

Marine Standards and Directives
IMO Resolution A754 (18) – Test Method for the Determination of the Fire Resistance of Separating Constructions
MED – Council Directive 96/98/EC on Marine Equipment

Green Building Standards
Stewardship and Sustainability
STI takes steps to minimize or eliminate volatile organic compounds (VOCs) and our products meet or exceed the
standards for sustainable design requirements and LEED® credits. No asbestos, PCB’s, or water soluble intumescent
ingredients are used or contained in all our products.

5

.	

Firestop Applications
Penetration Firestop Systems
Single & Multiple Penetrants
Cable Tray
• Composite sheet		
• Mortar			
• Pillows
Electrical Cables
• SSS			
• LCI			
• Putty			
Metallic Pipes
• SSS			
• LCI			
• Putty			
• Pillows			
• SIL

• EZ-Path	
• Ready Sleeve	
• SIL

• Cast-In Device		
• Composite Sheet	
• LC			
• Mortar			

Plastic Pipes
• Collars			
• Cast-In Device		
• SIL			

• SSS
• LCI
• Wrap Strip

Insulated Pipes
• Wrap Strip			
• LCI			

• SSS
• SIL

Ducts
• Composite Sheet		
• FyreFlange			
• LC				
• SIL
Bus Ducts
• Composite Sheet		
• Pillows			
• Mortar			

AS - elastomeric firestop spray
Cable Spray - firestop cable coating
Cast-In Device - firestop device for pipes
Collars - LCC firestop collars
Collars - SSC high performance firestop collars
Composite Sheet - intumescent firestop panel

6

• SSS
• LCI

Page 8
Page 12
Page 18
Page 16
Page 16
Page 18

• SSS
• LCI
• Mortar		

• SSS
• LCI
• SIL

Electrical Box Insert - intumescent firestop pad
ES - elastomeric firestop sealant
EZ-Path - fire rated pathway
Fast Tack - silicone based firestop spray
Firestop Plug - intumescent and flexible
FyreFlange - firestop angle for ducts

Page 19
Page 8
Page 20
Page 9
Page 15
Page 19

.	

Firestop Applications

Construction Joints
All static and dynamic joints
Narrow Joints
• ES		

Wide Joints
• AS		

• SIL
• Fast Tack

Data-Communication
High Traffic Openings

• EZ-Path® - The most advanced firestop solution
• Pillows - Easy installation and reinstallable
• Ready® Sleeve & Putty - Easy and retrofitable

• Ready® Firestop Grommet - For single and multiple cable penetrations

Curtain Wall Gaps

Wide Range of Construction
• AS - Water Based Spray

• Fast Tack - Silicone Based Spray

Cable Spray

Cable Jacketing Integrity
• Cable Spray - Coating designed to prevent
propagation of fire on cables

Electrical Box
• Electrical Box Inserts - The firestop solution
specifically designed for electrical boxes

Acoustical Products

Smoke, Noise and Infectious/Dust Control
Joints and Penetrations
• Smoke N Sound Sealant - For small openings
• Smoke N Sound Spray - For large openings

LC - endothermic firestop sealant
LCI - intumescent firestop sealant
Mortar - SSM lightweight firestop mortar
Pillows - SSB intumescent firestop pillows
Putty - SSP intumescent firestop putty/pads
Ready Firestop Grommet - for single cable

Page 10
Page 11
Page 12
Page 15
Page 13
Page 17

Ready Sleeve - firestop sleeve for new and existing cables
SIL - one-part neutral curing firestop silicone
Smoke N Sound - acoustical sealant & spray
Speedflex Joint Profile - joint cover solution
SSS - two stage intumescent firestop sealant
Wrap Strip - firestop wrap for combustible pipes

Page 14
Page 9
Page 13
Page 10
Page 11
Page 17

7

	

AS Elastomeric Firestop Spray

AS Elastomeric Spray is a non-halogenated, latex based, highly elastomeric spray
coating designed to provide passive smoke and fire protection in construction joints,
curtain wall gaps and certain penetrations.
This spray is designed to adhere to virtually all construction surfaces and may be applied using airless spray equipment or with a brush. Its premium latex binder system is
totally resistant to water and will not re-emulsify after drying.

Physical Properties

1366 •

6• E
47

N

• BS
02

	

Water based – for easy installation and cleanup
Water resistant
Paintable
Non-halogenated, no solvents, no asbestos, low VOC content
Auto bonding – allows fresh spray to adhere to cured spray
Low abrasion – for longer pump life and less maintenance
Thixotropic – for high-build application
High movement capabilities (25%)
Sound insulation (STC 61)
Tested with spray applied fire resistive materials (SFRM)
Color – light blue or red

DIN 41

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

REF:

volume

type

quantity

Color

weight (KG)

AS205

19.0 L

Pail

1

Light Blue

22.7

AS205R

19.0 L

Pail

1

Red

22.7

ES Elastomeric Firestop Sealant

ES Elastomeric Sealant is a non-halogenated latex-based, highly elastomeric caulk
designed to provide passive smoke and fire protection in construction joints. It is engineered to restore sound attenuation properties to sound-rated ceilings and partitions.
This sealant is designed to adhere to virtually all construction surfaces and may be
applied using standard caulking equipment or by troweling. Its premium latex binder
system is totally resistant to water and will not re-emulsify after drying.

Physical Properties

6• E
47

N

1366 •

• BS
02

8

Water based – for easy installation and cleanup
Water resistant
Paintable
Non-halogenated, no solvents, no asbestos, low VOC content
Auto bonding – allows fresh sealant to adhere to cured sealant
Thixotropic – for high-build application
High movement capabilities (25%)
Sound insulation (STC 62) – tested as acoustical sealant

DIN 41

•	
•	
•	
•	
•	
•	
•	
•	

REF:

volume

type

quantity

Color

weight (KG)

ES100

300 ml

Tube

12

Light Blue

0.50

ES100R

300 ml

Tube

12

Red

0.50

ES120

592 ml

Sausage

12

Light Blue

0.90

ES120R

592 ml

Sausage

12

Red

0.90

ES105

19.0 L

Pail

1

Light Blue

28.2

ES105R

19.0 L

Pail

1

Red

28.2

	

Fast Tack™ Firestop Spray

Fast Tack™ Firestop Spray is an elastomeric single component silicone/urethane hybrid spray coating designed to provide passive smoke and fire protection in horizontal
construction joints and curtain wall gaps.
This spray is designed to adhere to virtually all construction surfaces and may be applied using airless spray equipment or with a brush. It dries rapidly and cures in the
presence of atmospheric moisture to form a durable, flexible, water resistant shield.

Physical Properties

6• E
47

N

1366 •

• BS
02

	

Water resistant – for water-tight sealing
Auto bonding – allows fresh spray to adhere to cured spray
Cures very fast – skins over quickly to resist water
Cures below freezing
Non-halogenated, no solvents, no asbestos, no PCBs, low VOC
Color – off white

REF:

volume

type

quantity

weight (KG)

FT305

19.0 L

Pail

1

22.2

DIN 41

•	
•	
•	
•	
•	
•	

SIL Silicone Firestop Sealant

SIL Silicone Sealant is a one-part neutral curing silicone sealant designed to provide
passive smoke and fire protection in construction joints and through-penetration applications. This sealant is designed to adhere to virtually all construction surfaces and
may be applied using standard caulking equipment or by troweling.
It reacts with atmospheric moisture to form a tough durable seal. This material can also
insulate openings to prevent damage from occasional water spillage and dust penetration in sensitive areas.

Physical Properties
Water resistant – for water-tight sealing
Auto bonding – allows fresh sealant to adhere to cured sealant
Ozone and UV Resistant – for outside applications
Excellent chemical resistance
Excellent smoke seal
High movement capabilities (50%)
Sound insulation (STC 61)
Low VOC
Color – concrete

6• E
47

N

1366 •

• BS
02

REF:

volume

type

quantity

weight (kg)

SIL300

300 ml

Tube

24

0.5

SIL320

592 ml

Sausage

12

0.92

SIL305

17.0 L

Pail

1

24.7

SIL320SL

592 ml

Sausage

12

0.92

SIL305SL

17.0 L

Pail

1

24.7

DIN 41

•	
•	
•	
•	
•	
•	
•	
•	
•	

9

	

Speedflex® Joint Profile

SpeedFlex® Joint Profile is a high temperature fibrous joint forming material for use in
top of wall construction joints. When installed with an approved STI firestop coating,
the profile allows economical installations and up to 100% compression and extension
in joint movement.
This solution replaces strips of mineral wool in the joint area between the fire-rated
wall assembly and the bottom of a steel deck or concrete floor.

Physical Properties
•	
•	
•	
•	
•	
•	
•	

Allows 100% compression or extension
Fast installation
Alternative to caulking joints
Replaces mineral wool
Clean and professional appearance
Can be used to repair cracked joints
Seismic testing

REF:
SFJP40

	

DIMENSIONS

HEIGHT X LENGTH X THICKNESS

density (kg/m3)

QUANTITY

WEIGHT (KG)

128 to 160

1

0.46

10.2 cm X 102 cm X 4.7 mm

LC Endothermic Firestop Sealant

LC Endothermic Sealant is a latex-based, high solids firestop compound. This material will seal non-combustible through-penetrants and joints against the spread of fire,
smoke, toxic gasses and water.
It is engineered to adhere to virtually all construction surfaces and may be applied using a standard caulk gun or by troweling. Its premium latex binder
system is totally resistant to water and will not re-emulsify after drying.

Physical Properties
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

Water based – for easy installation and cleanup
Water resistant
Endothermic fillers – absorbs heat and release water
Non-halogenated, no solvents, no asbestos, low VOC content
Auto bonding – allows fresh sealant to adhere to cured sealant
High solids formula – no shrinkage
Thixotropic – for high-build application
Flexible
Sound insulation (STC 61)
Color – red
REF:

10

VOLUME

TYPE

QUANTITY

WEIGHT (KG)

LC150

300 ml

Tube

12

0.43

LC120

592 ml

Sausage

12

0.87

LC155

19.0 L

Pail

1

26.3

	

SSS Intumescent Firestop Sealant

SSS Intumescent Sealant is a product designed to seal a wide range of through-penetrants against the spread of fire, smoke, toxic gasses and water. It is a two stage intumescent technology product, which expands aggressively to quickly close off voids left
by the burning or melting of combustible materials.
This sealant is designed to adhere to virtually all construction surfaces and penetrant
materials. It may be applied using standard caulking equipment or by troweling. It has
excellent caulking properties on vertical or overhead surfaces. It will not separate or
shrink when dried. It contains no solvents.

Physical Properties
•	
•	
•	
•	
•	
•	
•	
•	
•	

Two stage intumescent – extremely fast and directionalized expansion
Water Based – for easy installation and cleanup
Water resistant
Auto bonding – allows fresh sealant to adhere to cured sealant
Endothermic properties
Non-halogenated, no solvents, no asbestos, no PCBs, low VOC content
High solids formula – no shrinkage when dried
Sound Insulation (STC 62)
Color – red
REF:

	

VOLUME

TYPE

QUANTITY

WEIGHT (KG)
0.50

SSS100

300 ml

Tube

12

SSS120

592 ml

Sausage

12

0.90

SSS102

7.6 L

Pail

1

11.4

SSS105

19.0 L

Pail

1

27.3

LCI Intumescent Firestop Sealant

LCI Intumescent Sealant is a product designed to seal a wide range of through-penetrants against the spread of fire, smoke, toxic gasses and water.
This sealant is designed to adhere to virtually all construction surfaces and penetrant
materials. It may be applied using standard caulking equipment or by troweling. It has
excellent caulking properties on vertical or overhead surfaces. It will not separate or
shrink when dried. It contains no solvents.

Physical Properties
Highly intumescent – up to 10x
Water based – for easy installation and cleanup
Water resistant
Auto bonding – allows fresh sealant to adhere to cured sealant
Endothermic properties
Non-halogenated, no solvents, no asbestos, no PCBs, low VOC content
No shrinkage when dried
Sound Insulation (STC 62)
Color – red

6• E
47

N

1366 •

• BS
02

REF:

VOLUME

TYPE

QUANTITY

WEIGHT (KG)

LCI300

300 ml

Tube

12

0.50

LCI320

592 ml

Sausage

12

0.90

LCI305

19.0 L

Pail

1

27.3

DIN 41

•	
•	
•	
•	
•	
•	
•	
•	
•	

11

	

CS Firestop Cable Spray

Cable Spray is an intumescent, latex-based spray applied coating designed to protect
grouped electrical cables against the propagation of fire. This material will limit flame
spread and provide short-term circuit integrity during a fire situation.
It is engineered to adhere well to virtually all cable jacketing materials and may be applied using airless spray equipment or with a brush. Its premium latex binder system is
totally resistant to water and will not re-emulsify after drying.

Physical Properties

1366 •

6• E
47

N

• BS
02

	

Intumescent – expands with heat
Water based – for easy installation and cleanup
Water and weather resistant
Non-halogenated, no solvents, no asbestos, low VOC content
Auto bonding – allows fresh sealant to adhere to cured sealant
Thixotropic – for high-build application
Flexible
High solids formula
Low abrasion – for longer pump life and less maintenance
Color – white
REF:

VOLUME

TYPE

QUANTITY

WEIGHT (KG)

CS105

19.0 L

Pail

1

25.00

DIN 41

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

SSM Firestop Mortar

Firestop Mortar is an economical, light-weight cement-based firestop product. This passive material uses a combination of heat sinking and insulating properties to provide a high
level of fire resistance.
It is designed to seal through-penetrations, construction gaps or blank openings. It can be
associated with other STI products. Its low density makes re-penetration for retrofitting
a simple task.
It is mixed with water and may be applied by pouring, pumping, or troweling.
Firestop Mortar is designed to dry quickly and will not crack or spall due to freezing or
changes in temperature.

Physical Properties
6• E
47

N

1366 •

• BS
02

12

Low density – easy retrofit
Light weight – less forming and support required
Fast drying – forms come down faster
Economical – highest yield per pound means lower installed cost
Versatile – wide range of applications
Chemical adhesion – reduces concrete fasteners needs
Color – pale red

REF:

VOLUME

TYPE

QUANTITY

WEIGHT (KG)

SSM106

22.7 L

Pail

1

10.90

SSM22B

--

Bag

1

10.50

DIN 41

•	
•	
•	
•	
•	
•	
•	

	

Smoke N Sound Acoustical Products

Smoke N Sound sealant and spray are high quality acrylic latex products designed
for sealing though-penetrations, linear joints and gaps in smoke rated barriers. This
solution is designed to adhere to virtually all construction surfaces. Its premium latex
binder system is totally resistant to water and will not re-emulsify after drying.
Smoke N Sound sealant may be applied using standard caulking equipment or by
troweling. It has excellent caulking properties on vertical or overhead surfaces
Smoke N Sound spray may be applied using airless spray equipment or with a brush
for small applications or touch ups.

Physical Properties
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

Water based – for easy installation and cleanup
Water resistant
Paintable
Non-halogenated, no solvents, no asbestos, low VOC content
Economical – high performance without the high price
Low abrasion – for longer pump life and less maintenance
Thixotropic – for high build application
Auto bonding – allows fresh sealant to adhere to cured sealant
Flexible – allows moderate movement (+8%)
Sound insulation (STC 61)
Sealant/
spray

QUANTITY

Sausage

Sealant

12

White

1.00

Pail

Sealant

1

Yellow

33.00

19.0 L

Pail

Sealant

1

White

33.00

19.0 L

Pail

Spray

1

White

26.00

REF:

VOLUME

TYPE

SNS120W

592 mm

SNS105

19.0 L

SNS105W
SNS205

	

Color

WEIGHT (KG)

SSP Intumescent Firestop Putty

SSP Intumescent Putty is a non-hardening compound designed to seal through-penetrations against the spread of fire, smoke and toxic gasses. Requiring no tools, it
is soft and pliable and can be installed by hand. Designed to adhere to all common
construction materials.
SSP Intumescent Putty Pads provides the same level of protection for easy
application to electrical boxes or other through-penetrants.

Physical Properties
Two stage intumescent – fast and aggressive expansion up to 50x
Soft and pliable – easy installation
Highly adhesive – allows movement
Non hardening – easy retrofit
Water resistant
Endothermic fillers – absorbs heat and release water
Sound insulation (STC 62 ) – excellent sound attenuation properties
Low VOCs
Color – red

6• E
47

N

1366 •
DIN 41

• BS
02

•	
•	
•	
•	
•	
•	
•	
•	
•	

REF:

VOLUME / DIMENSIONS

Type

quantity

WEIGHT (KG)

SSP100

0.6 L

Tube

6

1.10

SSP28

0.4 L

Tube

1

0.84

SSP4S

184 mm X 184 mm X 5 mm

Pad

20

0.27

SSP9S

229 mm X 229 mm X 5 mm

Pad

20

0.45

13

	

Ready® Sleeve

Ready® Sleeve firestop pathways are a complete out-of-the-box solution for new cable
penetrations through walls.
Each sleeve kit contains a precut metallic sleeve, mounting plates, intumescent gaskets, wall warning labels, and the amount of putty required to seal both ends. Our
51mm and 102mm diameter sleeves include a unique rolled lip design to eliminate
potential sharp edges.

Physical Properties
Ready to install – no cutting required, no waste
Smooth entry – no sharp edge
Economical – material and labor savings
Locks into place – no supports or clamps required
No external firestop seal required
Intumescent gasket provided with kit – expansion up to 15x
Intumescent firestop putty provided with kit – expansion up to 8x

1366 •

6• E
47

N

DIN 41

• BS
02

•	
•	
•	
•	
•	
•	
•	

min.
opening

max.
opening

length

plate sizes

quantity

weight (kg)

Ø 25 mm

Ø 30 mm

Ø 32 mm

300 mm

Ø 55 mm

6

0.50

Ø 51 mm

Ø 60 mm

Ø 65 mm

300 mm

Ø 86 mm

6

1.00

FS201

Ø 51 mm

Ø 60 mm

Ø 65 mm

300 mm

Ø 115 mm

6

1.20

FS400

Ø 102 mm

Ø 114 mm

Ø 114 mm

300 mm

Ø 140 mm

1

2.70

FS401

Ø 102 mm

Ø 114 mm

Ø 114 mm

300 mm

Ø 205 mm

1

2.90

REF:

sleeve sizes

FS100
FS200

	

Ready® Split Sleeve

Ready® Split Sleeve firestop pathways are a complete out-of-the-box solution for new
or existing cable penetrations through walls.
Each sleeve kit contains a precut metallic sleeve, mounting plates, intumescent gaskets,
wall warning labels, and the amount of putty required to seal both ends. Each size includes
a unique rolled lip design to eliminate potential sharp edges.

Physical Properties

1366 •

6• E
47

N

• BS
02

14

Split design for existing cables
Large plates – cover oversized openings
Ready to install – no cutting required, no waste
Smooth entry – no sharp edges
Economical – material and labor savings
Locks into place – no supports or clamps required
No external firestop seal required
Intumescent gasket provided with kit – expansion up to 15x
Intumescent firestop putty provided with kit – expansion up to 8x

DIN 41

•	
•	
•	
•	
•	
•	
•	
•	
•	

REF:

sleeve sizes

min.
opening

max.
opening

length

plate sizes

quantity

weight (kg)

FSR100

Ø 25 mm

Ø 30 mm

Ø 57 mm

300 mm

76 mm X 76 mm

4

0.57

FSR200

Ø 51 mm

Ø 60 mm

Ø 102 mm

300 mm

114 mm X 114 mm

4

1.26

FSR400

Ø 102 mm

Ø 114 mm

Ø 152 mm

300 mm

203 mm X 203 mm

4

3.28

	

FP Intumescent Firestop Plugs

Series FP Intumescent Firestop Plugs are soft and supple foam plugs molded from
polyurethane. Plugs are conveniently sized to fit 51 or 102 mm diameter openings or
metallic sleeves.
These plugs are designed to firestop single or bundled cables and blank openings. The
intumescent plugs expand when exposed to heat to quickly close off around combustible jacketed cables.

Physical Properties
•	
•	
•	
•	
•	
•	

Intumescent – expands in all directions up to 10x
Fast and easy installation – no special tools required
Reinstallable – soft resilient foam
Smoke resistant – superior smoke leakage ratings
Low VOC
Color – red

REF:

	

opening / sleeve dimensions

QUANTITY

WEIGHT (KG)

FP200

Ø 51 mm

10

0.61

FP400

Ø 102 mm

10

1.25

SSB Intumescent Firestop Pillows

Firestop Pillows are designed to firestop through penetrations in wall and floor applications. These intumescent and highly resilient pillows are installed in openings by
compressing and stacking into the opening in a brick-like fashion. This method of sealing offers easy retrofitting of through-penetrants without damaging the firestop seal.
Pillows consist of a mineral fiber core material sealed with a water resistant intumescent membrane. This coated core material is heat-sealed in a tough, non-irritating,
fire-retardant polythene bag.

Physical Properties
Intumescent – expands in all directions
Lightweight
Easy installation – no tools required
Reinstallable – for easy through-penetrant retrofitting
Good air leakage rating
Heat sealed poly bag – strong, durable and no irritating fiberglass
Low VOC
Color – red

SSB14

DIMENSIONS

HEIGHT X LENGTH X THICKNESS

25 mm X 101 mm X 229 mm

6• E
47

1366 •

• BS
02

REF:

N

DIN 41

•	
•	
•	
•	
•	
•	
•	
•	

QUANTITY

WEIGHT (KG)

20

0.09

SSB24

50 mm X 101 mm X 225 mm

10

0.13

SSB26

50 mm X 152 mm X 225 mm

22

0.16

SSB36

76 mm X 152 mm X 225 mm

16

0.22

15

	

SSC Intumescent Firestop Collars

SSC Intumescent Collars are factory-manufactured collars designed to firestop plastic
pipes. A molded intumescent insert is set in a galvanized metal collar.
The insert uses a two-stage intumescent technology, providing a very responsive and
highly directionalized expansion.
From a temperature of 120°C, the intumescent insert begins to expand rapidly to seal
completely the through-penetration. The expansion continues up to 538°C.

Physical Properties

6• E
47

N

REF:

pipe trade size

quantity

weight (kg)

SSC150

Ø 38 mm

6

0.11

SSC200

Ø 50 mm

6

0.14

SSC300

Ø 76 mm

6

0.23

SSC400

Ø 102 mm

6

0.37

SSC600

Ø 152 mm

2

2.12

LCC & RTC Intumescent Firestop Collars

LCC Intumescent Collars are factory-manufactured collars designed to firestop plastic
pipes. A molded intumescent insert is set in a galvanized metal collar. LCC collars are
specifically sized to fit 38mm, 51mm, 76mm and 102mm diameter trade sized pipes.
From a temperature of 160°C, the intumescent insert begins to expand rapidly to completely seal the through-penetration. The expansion continues up to 538°C.
RTC Intumescent Collars are adjustable collars designed to seal 76mm and 102mm
diameter trade size pipes.

Physical Properties
•	
•	
•	
•	

16

1366 •

• BS
02

	

Two-stage intumescent technology
Very fast expansion – seal off burning penetrants
Easy installation – fixation design reduces field labor
Water resistant – no soluble or hydroscopic ingredients

Highly intumescent – expansion up to 60x
Fast expansion – seal off burning penetrants
Easy installation – quick closure design
Water resistant – no soluble or hydroscopic ingredients

REF:

pipe trade size

quantity

weight (kg)

LCC150

Ø 38 mm

6

0.10

LCC200

Ø 50 mm

6

0.12

LCC300

Ø 76 mm

6

0.23

LCC400

Ø 102 mm

6

0.33

RTC350

Ø 76 mm and Ø 102 mm

6

0.34

DIN 41

•	
•	
•	
•	

	

SSW Intumescent Firestop Wrap Strip

Intumescent Wrap Strips are highly flexible, elastomeric strips designed to firestop combustible penetrations. Convenient rolls, or individually sized strips facilitate installation
and minimize waste.
These products utilize an intumescent technology, providing very responsive and highly
directionalized expansion. Their fast expansion provides quick closure of burning combustible penetrants.
From a temperature of 120°C, the intumescent strip begins to expand rapidly to seal
completely the through-penetration. The expansion continues up to 538°C.

Physical Properties
Highly intumescent – expansion up to 60x
Fast expansion – seal off burning penetrants
Water resistant – no soluble or hygroscopic ingredients
Easy installation – soft and flexible, less strip and less fasteners required
Economical – rolls or precut strips means no piecing, less waste
Versatile solution – for a wide range of applications

1366 •

6• E
47

N

DIN 41

• BS
02

•	
•	
•	
•	
•	
•	

Wrap Strip
REF:

DIMENSIONS

TYPE

SSWBLU2

Wrap Strip Roll

SSWRED2

Wrap Strip Roll

LENGTH X HEIGHT X THICKNESS

pipe size

quantity

weight (KG)

3.7 m X 51 mm X 3.2 mm

--

8

0.72

3.7 m X 38 mm X 3.2 mm

--

8

0.52

SSWBLU220

Wrap Strip Precut

20 mm X 38 mm X 3.2 mm

Ø 52 mm

25

0.05

SSWBLU230

Wrap Strip Precut

284 mm X 76 mm X 3.2 mm

Ø 76 mm

25

0.10

SSWBLU240

Wrap Strip Precut

356 mm X 102 mm X 3.2 mm

Ø 102 mm

25

0.14

Metal Restraining Collar
REF:

length

pipe size

to be used with

quantity

weight (KG)

SSWRC

7.6 m

--

SSWBLU2

1

2.30

SSWRC2

7.6 m

--

SSWRED2

1

1.70

WSC-8

--

Ø 152 mm and Ø 203 mm

SSWBLU2

1

0.69

WSC-8RED

--

Ø 152 mm

SSWRED2

1

0.48

WSC-12

--

Ø 254 mm and Ø 305 mm

SSWBLU2

1

0.91

	

Ready® Firestop Grommet

Ready® Firestop Grommet is a molded, two-piece grommet with an integral fire and
smoke sealing foam membrane. It is designed to seal individual cable penetrations
against fire and smoke through framed wall assemblies.
A soft foam inner core conforms to the cable to form a tight seal. Grommet snaps
together around cable and locks tightly into the wall.

Physical Properties
•	
•	
•	
•	
•	
•	
•	

Easy firestop solution
Smoke seal
Split design – for previously installed cables
Made with Ultem® premium, plenum grade material – exceptional flame and heat resistance
Designed for gypsum wall
No sleeve, no sealant required
Color – red

REF:

length

required
opening

max cable
diam.

quantity per
blister

quantity per
pack

weight (g)

RFG1

41 mm

Ø 14 mm

Ø 7 mm

10 Grommets

10 Blisters

5

17

	

Cast-In Firestop Device

Cast-In Firestop Devices consist of molded plastic sleeves incorporating an intumescent firestopping system and a flexible smoke and water resistant seal. It has been
engineered for use in concrete floors to firestop openings for various combustible and
non-combustible penetrants.
The molded plastic body can be easily cut as required to accommodate concrete
thickness. Steel deck kits are available to facilitate installation in fluted metal decks as
well as extension tubes for thicker floors.

Physical Properties
Easy installation – eliminates core drilling
Water and smoke resistant gasket
Intumescent material already incorporated in the device
Available in four diameters
Saves time – no firestopping step required
Can be easily cut to adapt the length
Metal deck kit for installation over steel deck
Extension tube for concrete greater thicker than 204mm
footprint

min. steel
deck opening

6• E
47

qty

weight
(KG)

6

0.50

CD200X

Devices for combustible and noncombustible penetrants (Red Device)
CD200

Ø 51 mm

131 mm X 131 mm

Ø 93 mm

1366 •

• BS
02

pipe
size

REF:

N

REF:

pipe
size

DIN 41

•	
•	
•	
•	
•	
•	
•	
•	

qty

weight
(KG)

Ø 51 mm

6

0.16

Ø 76 mm

6

0.19

Extension Tubes

CD300

Ø 76 mm

146 mm X 146 mm

Ø 108 mm

6

0.60

CD300X

CD400

Ø 102 mm

172 mm X 172 mm

Ø 134 mm

6

0.75

CD400X

Ø 102 mm

6

0.21

CD600

Ø 152 mm

229 mm X 229 mm

Ø 184 mm

6

1.10

CD600X

Ø 152 mm

6

0.29

Metal Deck Adapters

Devices for noncombustible penetrants (Black Device)
CD200M

Ø 51 mm

131 mm X 131 mm

Ø 93 mm

6

0.50

CD200DK

Ø 51 mm

6

0.20

CD300M

Ø 76 mm

146 mm X 146 mm

Ø 108 mm

6

0.60

CD300DK

Ø 76 mm

6

0.32

CD400M

Ø 102 mm

172 mm X 172 mm

Ø 134 mm

6

0.75

CD400DK

Ø 102 mm

6

0.40

CD600M

Ø 152 mm

229 mm X 229 mm

Ø 184 mm

6

1.10

CD600DK

Ø 152 mm

6

1.15

Ø 51 mm

1

1.15

Tub Box Kit
CD200T

	

Composite Sheet

The intumescent Composite Sheet is a lightweight, rigid firestop panel consisting of an
intumescent layer bonded to a galvanized steel sheet reinforced with steel wire mesh
covered with aluminum foil. It is designed to seal medium to large size openings with
a variety of different penetrants. When exposed to temperatures in excess of 177°C,
Composite Sheet expands minimum 15x to form a dense insulative char that minimizes heat transfer.

Physical Properties
•	
•	
•	
•	
•	

18

Highly intumescent – expands up to 15x
Lightweight – easy handling and less hanging weight
Easy to cut – using simple sheet metal tools
Hole reduction – reduce large openings
Versatile solution – wide range of applications
REF:

pipe trade size

quantity

weight (kg)

CS1628

41 cm X 71 cm

1

2.72

CS2436

61 cm X 92 cm

1

5.00

CS3636

92 cm X 92 cm

1

7.26

CS3641

92 cm X 104 cm

1

7.71

CS2852

71 cm X 132 cm

1

8.62

	

FyreFlange™ Firestop Angle

FyreFlange™ Firestop Angles consist of galvanized steel retaining angles with a layer
of bonded intumescent material designed to be installed around the perimeter of nondampered rectangular steel ducts. It can be installed as the duct is installed and inspected just once after the installation is complete.
In the event of fire, FyreFlange™ Firestop Angles prevent duct collapse and minimize
deflection. When exposed to temperatures in excess of 177°C, its intumescent system
expands to form a dense insulative char that stops the spread of fire and minimizes
heat transfer.

Physical Properties
•	
•	
•	
•	
•	
•	
•	
•	

	

Intumescent gaskets – expands to 15 times
Economical – Saves labor
Easy installation
Versatile – use for insulated and non insulated ducts
Can be installed over or under duct insulation
No additional firestop materials required
Easy identification and inspection
Color – red
REF:

Designation

DIMENSIONS

quantity

WEIGHT (KG)

FFA2208

Firestop Angle

51 mm X 51 mm X 244 cm

6

1.93

FFC22

Corner Clips

--

8 per bag

0.37

FFS22

Splice Pack

--

6 per bag

0.32

PowershieldTM Electrical Box Inserts

Powershield electrical box insert is a one-component pad designed to provide passive
smoke and fire protection in electrical switch or receptacle boxes.
The intumescent insert has been designed to install inside the box, directly against the
back wall. It features an adhesive strip applied to the back of the pad to ensure adhesion to the back of an electrical box.

Physical Properties
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

Highly intumescent – Expands up to 24x
Rapid expansion – seal off passage of fire and smoke quickly
Water resistant – no soluble or hygroscopic ingredients
Easy installation – just peel and stick it inside of box
One step installation – saves time and labor
Easy retrofit
No clean-up required – no mess, no residue
Thin profile to maximize area inside box
Sound insulation (STC 64 ) – excellent sound attenuation properties
Non-conductive liner face – safe for use inside box
Color – red
REF:

dimensions

quantity

weight (kg)

EP44

9.5 cm X 9.5 cm X 0.32 cm

20

0.04

EP45

10.8 cm X 10.8 cm X 0.32 cm

20

0.07

19

Maximum Fire & Smoke Protection
•	 Maximum resistance to fire and smoke whether 	
	
empty or 100% visually filled.
•	 Assures fire and smoke protection with every 	
	
new or retrofit cable installation.
•	 Superior fire and smoke leakage vs. standard 	
	
sleeve and putty systems.
•	 Unlike conventional sleeve and putty systems, 	
	EZ-Path® remains fire and smoke compliant 	
	
100% of the time.

No Firestopping Required
•	
	
•	
•	
	
	

Built-in firestopping system automatically
adjusts to the number of cables installed.
Design assures it is firestopped at all stages of use.
Mechanical application eliminates the use of	
sealant, putty and other products that need to 	
be removed and replaced.

Fast-Acting Intumescent Material
•	
	
•	
	
	
•	
	
	

20

Engineered for rapid expansion when exposed 	
to fire or high temperatures.
Intumescent material responds to flames or 	
heat by quickly sealing the pathway and pre-	
venting the passage of flames and smoke.
Innovative built-in firestop design assures it 	
is firestopped and smoke-sealed — even at 	
maximum cable loading.

Performance
•	
	
•	
	
•	
•	
•	
	
•	
	
•	

UL® Classified and FM Approved in accor-	
dance with ASTM E814 (UL1479).
UL systems are available for up to 4 hour rated 	
floor and wall constructions.
Tested according to EN 1366, DIN 4102 & BS 476.
Test and approved for marine applications.
Empty or full, EZ-Path® is continuously code 	
compliant — 100% of the time.
Tested and approved cable capacities range 	
from 0 to 100% visual fill.
U.S. Patent 6,732,481

All-in-one design installs in minutes.
Conveniently packaged kits for easy installation 	
— no additional parts to order.
Splits apart for old work.
Clean, professional, engineered appearance.
Easy moves, adds and changes.
Can be installed as the wall is being built.

la

l
nI
ts

I nI
tin it ia
ai
lI

•	
•	
	
•	
•	
•	
•	

ns
ta
ll

Pays For Itself In A Few Cable Changes

Specifications
6• E
47

N

1366 •
DIN 41

• BS
02

All data, video, and communications cable bundles
shall utilize an enclosed fire rated pathway device
wherever said cables penetrate rated walls. The
fire-rated pathway shall contain a built-in fire sealing system sufficient to maintain the hourly fire rating
of the barrier being penetrated. The self-contained
sealing system shall automatically adjust to the installed cable loading and shall permit cables to be
installed, removed, or retrofitted without the need to
adjust, remove or reinstall firestop materials.

21

Modular Floor Grid System
An EZ-Path® Solution for High Volume Cable
Penetrations through Floors
Now there is a bolt-in solution for riser applications
that brings the safety and simplicity of EZ-Path® to
your vertical cable installations.
The EZ-Path® Modular Floor Grid System can handle
literally thousands of cables.
Modular Floor Grid Systems utilize the high volume,
EZ-Path® Series 44 Pathways installed in banks
of four to provide your cabling systems with room
to grow. Sturdy steel grids mount one, two or four
banks of pathways in built-in slots for a total of up
to sixteen pathways through a single floor opening.
A single bank Floor Grid comes complete with Pathways. Multi-bank Modular Floor Grids are installed
with firestop panels sealing each slot. As additional
cable capacity is required, firestop panels are removed and pathway modules containing four pathways are installed in each slot.

Capacity: 8 Pathways

Cat No. EZD444

Cat No. EZG1644

Capacity: 4 Pathways

Capacity: 16 Pathways

Sold complete with grid
and pathways

22

Cat No. EZG844

SERIES 22

SERIES 33

SERIES 44

Height X Width

38 mm X 38 mm

76 mm X 76 mm

102 mm X 102 mm

Length

267 mm

267 mm

267 mm

Can Be Ganged

Up to 3

Up to 7

Up to 5 in walls
Up to 16 in floors

Can Be Lengthened

--

152 mm increments

--

Insert Into Cored Hole

51 mm

102 mm

153 mm

Fire Rated In Walls / Floors

Up to 4 Hour

Up to 4 Hour

Up to 4 Hour

Approx. Max Cable Capacity

25 +

120 +

244 +

Approx. Max Cable Capacity (Ganged)

75 +

840 +

1220 +

Approx. Max Cable Capacity
(Grid)

--

--

3904 + in floors

Ref:

Description

qty

Weight (KG)

6

0.91

EZ-Path® Series 22 Fire Rated Pathway Kits
EZD22

22 Series - Fire-Rated Pathway Device Kit

EZ-Path Series 33 Fire Rated Pathway Kits
®

EZD33FWS

Series 33 - Fire-Rated Pathway Device

6

1.22

EZD33E

Series 33 - Extension Module

1

0.68

EZP133W

Series 33 - Single Square Wall Plate Pack

1

0.20

EZP133CW

Series 33 - Single Circular Wall Plate Pack

1

0.37

EZP233W

Series 33 - Double Wall Plate Pack

1

0.32

EZP333W

Series 33 - Triple Wall Plate Pack

1

0.47

EZP433W

Series 33 - Four-Gang Plate Pack

1

0.88

EZP733W

Series 33 - Seven-Gang Plate Pack

1

1.15

EZP133K

Series 33 - Single Kick-In Plate Pack - (For use with floor applications)

6

0.31

EZP133R

Series 33 - Retro-Fit Mounting Plate Pack

1

1.58

EZP133CA

Series 33 - Conduit Attachment Plate Pack

1

0.41

RCM33

Series 33 - One Pair (2) Radius Control Modules

1

0.02

EZ-Path Series 44 Fire Rated Pathway Kits
®

EZD44

Series 44 - Fire-Rated Pathway Device

4

3.04

EZDG444

Series 44 - Single Bank Floor Grid - Four (4) Devices With Floor Frame

1

18.60

EZD444MB

Series 44 - Single Bank of Devices - Four (4) Devices With Hanger Bracket

1

13.16

EZP144W

Series 44 - Single Wall Plate Pack

1

1.00

EZP544W

Series 44 - Multi Gang Wall Plate Pack

1

1.82

EZP144F

Series 44 - Split Floor Plate Pack

1

0.69

EZG844

Series 44 - Multi Slot Frame For Eight (8) Pathways

1

7.26

EZG1644

Series 44 - Multi Slot Frame For Sixteen (16) Pathways

1

12.03

23



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2012:11:08 16:06:01-05:00
Metadata Date                   : 2012:11:08 16:09:57-05:00
Modify Date                     : 2012:11:08 16:09:57-05:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 9330 bytes, use -b option to extract)
Instance ID                     : uuid:d8da7b4f-0de2-9043-828b-91e8b396c584
Original Document ID            : xmp.did:018011740720681192B0AC7194B25305
Document ID                     : xmp.id:301BE0FB362068118A6D8A0CC306359A
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:7652A825262068119457DC47F1C4FBE8
Derived From Document ID        : xmp.did:F1A7AD9836206811A961DA58CBA0BAC8
Derived From Original Document ID: xmp.did:018011740720681192B0AC7194B25305
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2012:11:08 16:06:01-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 24
Creator                         : Adobe InDesign CS6 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu