Product Detail Manual
2014-11-11
: Pdf 71202-Attachment 71202-Attachment 730573 Batch12 unilog
Open the PDF directly: View PDF .
Page Count: 24
Specied Technologies Inc. (STI) is an industry leader solely committed to the de-
velopment of innovative and reliable restop solutions to stop the spread of re,
smoke and toxic gasses.
For over 20 years, STI has worked hand-in-hand with the construction industry
to create modern restop solutions for all types of new construction and retrot
applications. Considering the increasing complexity of new building constructions,
this is no small task. All of our systems are tested and certied by accredited laboratories
all over the world, and we offer the broadest range of UL Classied Systems, more than any other re-
stop manufacturer. STI develops and manufactures innovative and reliable restop solutions for a very
wide range of penetrations and joint applications.
STI takes steps to minimize or eliminate volatile organic compounds (VOCs) and our products meet or
exceed the standards for sustainable design requirements and LEED® credits.
Summary of Contents
Firestopping Overview
Elements of Fire Protection ................................................................................................. Page 4
Passive Fire Protection - Firestopping ................................................................................ Page 4
Worldwide Standards .......................................................................................................... Page 5
Products and Applications
Application Selector ............................................................................................................ Page 6
Product Information ............................................................................................................ Page 8
EZ-Path® Fire Rated Pathway
Features and Benets ......................................................................................................... Page 20
Ordering Information ........................................................................................................... Page 23
2
A Few STI References...
3
Institutions Industrial / Infrastructure High Rise Buildings Healthcare Facilities
KAUST – Jeddah Substations – Qatar Emirates Towers- Dubai Mayo Clinic - USA
PNUW – Riyadh Nestle – Russia Shams Towers- Abu Dhabi Cleveland Clinic- USA
Al Ain University – Al Ain Rolex – Switzerland Etihad Towers- Abu Dhabi Al Saad Hospital- KSA
CEA center – Paris Charles de Gaulle Airport – Paris KAFD- Riyadh Saudi German Hospital- KSA
Palexpo – Switzerland Genève Airport – Switzerland Silhouette tower- Doha Hôpitaux Universitaire de Genève
Harvard University – USA SNCB – Belgium 10 Kings Road-Jeddah Sano Aventis - Mexico
Johns Hopkins University – USA Unilever DataCenter – UK Jabal Al Kaaba- Mecca Hôpitaux Universitaire de Reins- France
New York University – USA Singtel Datacenter – Singapore Rose Rotana Suites -Dubai US Air Force Medical Command- USA
Crédit Suisse – Zurich Télévision Suisse Romande – Switzerland Rotana Khalidiya Palace- Abu Dhabi King Hamad Hospital- Bahrain
Caserne de pompier – Genève EUROCONTROL – Belgium Central Market-Abu Dhabi Stanford University Medical Center – USA
KLCC Towers
Kuala Lumpur
Malaysia
Dubai International Airport
Emirates Tower, Dubai
Etihad Towers, Abu Dhabi
United Arab Emirates
KAFD
Riyadh,
Saudi Arabia
KAUST
Jeddah,
Saudi Arabia
Al-Saad Hospital
Dammam,
Saudi Arabia
Sabiya Power Plant
Kuwait
P 911 Project (U.S. Naval Base)
Ministry of Electricity and Water
National Bank of Bahrain
Cabras Power
Plant
ChiMei Semiconductor Project
Quanta Display Project
Taiwan Semiconductor Mfg.
Taiwan
US Army Base Pyungtaek,
PoongLim (Phase I & II)
Korea
Pacic Plaza Towers
Malayan Towers
Philippines
Cal State
Fresno, CA
Air Force Academy
Colorado Springs, CO
Boeing Aircraft
Renton, WA
Stanford University
Palo Alto, CA
Argonne National
Laboratories
Argonne, IL
Atlanta
Financial
Center
Atlanta, GA
Madero Renery
Shriner’s Hospital
Proctor and Gamble Plant
Mexico
New Social Security
Building
Panama
Nextel Switching
Stations – Buenos Aires
Borgata Hotel and Casino
Atlantic City, NJ
Beaches Resort – Italian Village Extension
Turks and Caicos Islands
Republic Bank Trinidad
Nextel Switching Stations
Caracas, Venezuela
Belgo-Mieira (Steel Plant)
Telemar (Telecom)
Brazil
7 World Trade Center
Hearst Tower
New York, NY
Bellagio Hotel and Casino
Las Vegas, NV
Children’s Hospital
of Philadelphia
Philadelphia, PA Children’s Hospital
Boston, MA
Charles de Gaulle Airport
Paris, France
Unilever DataCenter
UK
Hôpitaux Universitaire de Genève
Genève, Switzerland
The Mayo Clinic
Rochester, MN
Syncrude
Fort McMurray, Alberta, Canada
Calgary South Medical Center
Calgary, Alberta, Canada
AT&T Switching Center
Cleveland Clinic
Cleveland, OH
Passive Fire Protection - Firestopping
No passive re protection system is complete without proper restopping systems. As service elements penetrate
re-resistive rated walls and oors, unsealed gaps around them will allow the spread of ames, smoke, and gasses
thereby neutralizing the eectiveness of such barriers. Installation of restopping materials to seal the gaps around
such penetrations restores the integrity of the barriers and maintains hourly re endurance ratings. The complete
STI line of restopping products entails all aspects of proper restopping from simple joints or gaps to single or
multiple penetrant systems such as pipes, cables, cable trays, or ducts.
The construction of barrier
walls and oors to withstand
the passage of re, smoke
and super-heated gasses.
Electrical or mechanical service
lines breach a re-barrier wall
or oor.
Firestop materials must be
installed to restore an hourly
re-rating.
Elements of Fire Protection
The essential elements of re protection can be classied as either passive or active re protection. Used in
conjunction with one another to provide a balanced re protection strategy in modern construction, both active
and passive re protection systems are analogous to safety belts and air bags in automobiles.
Active re protection elements are designed to activate once a re starts to control growth or extinguish it.
Examples include re sprinklers or gaseous extinguishing systems. Fire alarms also fall into this category as
they provide notication to building occupants and emergency responders.
Passive re protection elements are designed to control re growth and spread through the erection of barriers that
minimize the spread of re, smoke, and hot gases. Such systems are said to compartmentalize or contain re to
the point or origin thereby allowing occupants time for safe egress and re ghting personnel time for safe ingress
to perform search and rescue. Passive re protection systems may also enhance structural integrity. Examples of
passive re protection include re-resistive rated oors and walls, re-proong materials for structural elements,
re doors, and re dampers. Firestopping is an essential element of an eective passive re protection system.
4
Worldwide Standards
North American Standards
ASTM Standards
E84 ...............................Test Method for Surface Burning Characteristics of Building Materials
E90 ................................Test Method of Airborne Sound Transmission Loss of Building Partitions and Elements
E136 ..............................Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C
E814 ..............................Test Method for Fire Tests of Through Penetration Firestops
E119 ..............................Test Method of Building Construction and Materials
E1399 ............................Test Method for Measuring the Minimum and Maximum Joint Widths of Architectural Joint Systems
E1966 ............................Test Method for Fire-Resistive Joint Systems
E2307 ............................Test Method for Determining Fire Resistance of Perimeter Fire Barrier Systems
UL Standards
UL263 ...........................Fire Test of Building Construction and Materials (equivalent to ASTM E119)
UL1479 .........................Fire Tests of Through Penetration Firestops (equivalent to ASTM E814)
UL2079 .........................Fire Tests for Fire Resistance of Building Joint Systems
ULC Standards
ULC S101 .....................Standard Method of Fire Endurance Tests of Building Construction Materials
ULC S102 .....................Standard Method of Testing for Surface Burning Characteristics of Building Materials & Assemblies
ULC S115 .....................Standard Method of Fire Tests of Firestop Systems
European Standards
EN Standards
EN 1366-3 ....................Fire Resistance Tests for Service Installations. Penetration Seals.
EN 1366-4 ...................Fire Resistance Tests for Service Installations. Linear Joint Seals.
EN ISO 11925-2 ...........Reaction To Fire Tests. Ignitability of Building Products Subjected to Direct Impingement of Flame
EN 13501-1 ..................Fire Classication of Construction Products and Building Elements Using Test Data From Reaction
To Fire Tests
EN 13501-2 ..................Fire Classication of Construction Products and Building Elements Using Data From Fire Resistance
Tests, Excluding Ventilation Services
DIN Standards
DIN 4102 .......................Fire Behavior of Building Materials and Building Components
DIN 4102-1 ...................Reaction To Fire Tests - Ignitability of Building Products Subjected To Direct Impingement of Flame
DIN 4102-2 ...................Building Components; Denitions, Requirements and Tests
DIN 4102-6 ...................Ventilation Ducts; Denitions, Requirements and Tests
DIN 4102-9 ...................Seals for Cable Penetrations; Concepts, Requirements and Testing
DIN 4102-11 .................Pipe Encasements, Pipe Bushings, Service Shafts and Ducts, and Barriers Across Inspection
Openings; Terminology, Requirements and Testing
British Standards
BS476-20 .....................Fire Tests on Building Materials and Structures. Part 20: Method for Determination of the Fire
Resistance of Elements of Construction (General Principles)
Marine Standards and Directives
IMO Resolution A754 (18) – Test Method for the Determination of the Fire Resistance of Separating Constructions
MED – Council Directive 96/98/EC on Marine Equipment
Green Building Standards
Stewardship and Sustainability
STI takes steps to minimize or eliminate volatile organic compounds (VOCs) and our products meet or exceed the
standards for sustainable design requirements and LEED® credits. No asbestos, PCB’s, or water soluble intumescent
ingredients are used or contained in all our products.
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
5
Penetration Firestop Systems
Single & Multiple Penetrants
Firestop Applications
6
Cable Tray
• Composite sheet • SSS
• Mortar • LCI
• Pillows
Insulated Pipes
• Wrap Strip • SSS
• LCI • SIL
Ducts
• Composite Sheet • SSS
• FyreFlange • LCI
• LC • Mortar
• SIL
Bus Ducts
• Composite Sheet • SSS
• Pillows • LCI
• Mortar • SIL
Electrical Cables
• SSS • EZ-Path
• LCI • Ready Sleeve
• Putty • SIL
Plastic Pipes
• Collars • SSS
• Cast-In Device • LCI
• SIL • Wrap Strip
Metallic Pipes
• SSS • Cast-In Device
• LCI • Composite Sheet
• Putty • LC
• Pillows • Mortar
• SIL
AS - elastomeric restop spray
Cable Spray - restop cable coating
Cast-In Device - restop device for pipes
Collars - LCC restop collars
Collars - SSC high performance restop collars
Composite Sheet - intumescent restop panel
Page 8
Page 12
Page 18
Page 16
Page 16
Page 18
Page 19
Page 8
Page 20
Page 9
Page 15
Page 19
Electrical Box Insert - intumescent restop pad
ES - elastomeric restop sealant
EZ-Path - re rated pathway
Fast Tack - silicone based restop spray
Firestop Plug - intumescent and exible
FyreFlange - restop angle for ducts
Firestop Applications
7
Curtain Wall Gaps
Wide Range of Construction
• AS - Water Based Spray
• Fast Tack - Silicone Based Spray
Cable Spray
Cable Jacketing Integrity
• Cable Spray - Coating designed to prevent
propagation of re on cables
Electrical Box
• Electrical Box Inserts - The restop solution
specically designed for electrical boxes
Acoustical Products
Smoke, Noise and Infectious/Dust Control
Joints and Penetrations
• Smoke N Sound Sealant - For small openings
• Smoke N Sound Spray - For large openings
Construction Joints
All static and dynamic joints
Narrow Joints
• ES • SIL
Wide Joints
• AS • Fast Tack
Data-Communication
High Trafc Openings
• EZ-Path® - The most advanced restop solution
• Pillows - Easy installation and reinstallable
• Ready® Sleeve & Putty - Easy and retrotable
Page 14
Page 9
Page 13
Page 10
Page 11
Page 17
Ready Sleeve - restop sleeve for new and existing cables
SIL - one-part neutral curing restop silicone
Smoke N Sound - acoustical sealant & spray
Speedex Joint Prole - joint cover solution
SSS - two stage intumescent restop sealant
Wrap Strip - restop wrap for combustible pipes
Page 10
Page 11
Page 12
Page 15
Page 13
Page 17
LC - endothermic restop sealant
LCI - intumescent restop sealant
Mortar - SSM lightweight restop mortar
Pillows - SSB intumescent restop pillows
Putty - SSP intumescent restop putty/pads
Ready Firestop Grommet - for single cable
• Ready® Firestop Grommet - For single and multiple cable penetrations
AS Elastomeric Firestop Spray
AS Elastomeric Spray is a non-halogenated, latex based, highly elastomeric spray
coating designed to provide passive smoke and re protection in construction joints,
curtain wall gaps and certain penetrations.
This spray is designed to adhere to virtually all construction surfaces and may be ap-
plied using airless spray equipment or with a brush. Its premium latex binder system is
totally resistant to water and will not re-emulsify after drying.
Physical Properties
• Water based – for easy installation and cleanup
• Water resistant
• Paintable
• Non-halogenated, no solvents, no asbestos, low VOC content
• Auto bonding – allows fresh spray to adhere to cured spray
• Low abrasion – for longer pump life and less maintenance
• Thixotropic – for high-build application
• High movement capabilities (25%)
• Sound insulation (STC 61)
• Tested with spray applied re resistive materials (SFRM)
• Color – light blue or red
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
ES Elastomeric Firestop Sealant
ES Elastomeric Sealant is a non-halogenated latex-based, highly elastomeric caulk
designed to provide passive smoke and re protection in construction joints. It is engi-
neered to restore sound attenuation properties to sound-rated ceilings and partitions.
This sealant is designed to adhere to virtually all construction surfaces and may be
applied using standard caulking equipment or by troweling. Its premium latex binder
system is totally resistant to water and will not re-emulsify after drying.
Physical Properties
• Water based – for easy installation and cleanup
• Water resistant
• Paintable
• Non-halogenated, no solvents, no asbestos, low VOC content
• Auto bonding – allows fresh sealant to adhere to cured sealant
• Thixotropic – for high-build application
• High movement capabilities (25%)
• Sound insulation (STC 62) – tested as acoustical sealant
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
8
REF: volumE typE quantity ColoR wEight (Kg)
ES100 300 ml Tube 12 Light Blue 0.50
ES100R 300 ml Tube 12 Red 0.50
ES120 592 ml Sausage 12 Light Blue 0.90
ES120R 592 ml Sausage 12 Red 0.90
ES105 19.0 L Pail 1 Light Blue 28.2
ES105R 19.0 L Pail 1 Red 28.2
REF: volumE typE quantity ColoR wEight (Kg)
AS205 19.0 L Pail 1 Light Blue 22.7
AS205R 19.0 L Pail 1 Red 22.7
REF: volumE typE quantity wEight (kg)
SIL300 300 ml Tube 24 0.5
SIL320 592 ml Sausage 12 0.92
SIL305 17.0 L Pail 1 24.7
SIL320SL 592 ml Sausage 12 0.92
SIL305SL 17.0 L Pail 1 24.7
SIL Silicone Firestop Sealant
SIL Silicone Sealant is a one-part neutral curing silicone sealant designed to provide
passive smoke and re protection in construction joints and through-penetration ap-
plications. This sealant is designed to adhere to virtually all construction surfaces and
may be applied using standard caulking equipment or by troweling.
It reacts with atmospheric moisture to form a tough durable seal. This material can also
insulate openings to prevent damage from occasional water spillage and dust penetra-
tion in sensitive areas.
Physical Properties
• Water resistant – for water-tight sealing
• Auto bonding – allows fresh sealant to adhere to cured sealant
• Ozone and UV Resistant – for outside applications
• Excellent chemical resistance
• Excellent smoke seal
• High movement capabilities (50%)
• Sound insulation (STC 61)
• Low VOC
• Color – concrete
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
Fast Tack™ Firestop Spray
Fast Tack™ Firestop Spray is an elastomeric single component silicone/urethane hy-
brid spray coating designed to provide passive smoke and re protection in horizontal
construction joints and curtain wall gaps.
This spray is designed to adhere to virtually all construction surfaces and may be ap-
plied using airless spray equipment or with a brush. It dries rapidly and cures in the
presence of atmospheric moisture to form a durable, exible, water resistant shield.
Physical Properties
• Water resistant – for water-tight sealing
• Auto bonding – allows fresh spray to adhere to cured spray
• Cures very fast – skins over quickly to resist water
• Cures below freezing
• Non-halogenated, no solvents, no asbestos, no PCBs, low VOC
• Color – o white
REF: volumE typE quantity wEight (Kg)
FT305 19.0 L Pail 1 22.2
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
9
Speedex® Joint Prole
SpeedFlex® Joint Prole is a high temperature brous joint forming material for use in
top of wall construction joints. When installed with an approved STI restop coating,
the prole allows economical installations and up to 100% compression and extension
in joint movement.
This solution replaces strips of mineral wool in the joint area between the re-rated
wall assembly and the bottom of a steel deck or concrete oor.
Physical Properties
• Allows 100% compression or extension
• Fast installation
• Alternative to caulking joints
• Replaces mineral wool
• Clean and professional appearance
• Can be used to repair cracked joints
• Seismic testing
REF: VOLUME TYPE QUANTITY WEIGHT (KG)
LC150 300 ml Tube 12 0.43
LC120 592 ml Sausage 12 0.87
LC155 19.0 L Pail 1 26.3
LC Endothermic Firestop Sealant
LC Endothermic Sealant is a latex-based, high solids restop compound. This mate-
rial will seal non-combustible through-penetrants and joints against the spread of re,
smoke, toxic gasses and water.
It is engineered to adhere to virtually all construction surfaces and may be applied us-
ing a standard caulk gun or by troweling. Its premium latex binder
system is totally resistant to water and will not re-emulsify after drying.
Physical Properties
• Water based – for easy installation and cleanup
• Water resistant
• Endothermic llers – absorbs heat and release water
• Non-halogenated, no solvents, no asbestos, low VOC content
• Auto bonding – allows fresh sealant to adhere to cured sealant
• High solids formula – no shrinkage
• Thixotropic – for high-build application
• Flexible
• Sound insulation (STC 61)
• Color – red
10
REF: DIMENSIONS
HEIGHT X LENGTH X THICKNESS DENSITy (KG/M3) QUANTITy WEIGHT (KG)
SFJP40 10.2 cm X 102 cm X 4.7 mm 128 to 160 1 0.46
REF: VOLUME TYPE QUANTITY WEIGHT (KG)
SSS100 300 ml Tube 12 0.50
SSS120 592 ml Sausage 12 0.90
SSS102 7.6 L Pail 1 11.4
SSS105 19.0 L Pail 1 27.3
SSS Intumescent Firestop Sealant
SSS Intumescent Sealant is a product designed to seal a wide range of through-pene-
trants against the spread of re, smoke, toxic gasses and water. It is a two stage intu-
mescent technology product, which expands aggressively to quickly close o voids left
by the burning or melting of combustible materials.
This sealant is designed to adhere to virtually all construction surfaces and penetrant
materials. It may be applied using standard caulking equipment or by troweling. It has
excellent caulking properties on vertical or overhead surfaces. It will not separate or
shrink when dried. It contains no solvents.
Physical Properties
• Two stage intumescent – extremely fast and directionalized expansion
• Water Based – for easy installation and cleanup
• Water resistant
• Auto bonding – allows fresh sealant to adhere to cured sealant
• Endothermic properties
• Non-halogenated, no solvents, no asbestos, no PCBs, low VOC content
• High solids formula – no shrinkage when dried
• Sound Insulation (STC 62)
• Color – red
LCI Intumescent Firestop Sealant
LCI Intumescent Sealant is a product designed to seal a wide range of through-pene-
trants against the spread of re, smoke, toxic gasses and water.
This sealant is designed to adhere to virtually all construction surfaces and penetrant
materials. It may be applied using standard caulking equipment or by troweling. It has
excellent caulking properties on vertical or overhead surfaces. It will not separate or
shrink when dried. It contains no solvents.
Physical Properties
• Highly intumescent – up to 10x
• Water based – for easy installation and cleanup
• Water resistant
• Auto bonding – allows fresh sealant to adhere to cured sealant
• Endothermic properties
• Non-halogenated, no solvents, no asbestos, no PCBs, low VOC content
• No shrinkage when dried
• Sound Insulation (STC 62)
• Color – red
REF: VOLUME TYPE QUANTITY WEIGHT (KG)
LCI300 300 ml Tube 12 0.50
LCI320 592 ml Sausage 12 0.90
LCI305 19.0 L Pail 1 27.3
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
11
CS Firestop Cable Spray
Cable Spray is an intumescent, latex-based spray applied coating designed to protect
grouped electrical cables against the propagation of re. This material will limit ame
spread and provide short-term circuit integrity during a re situation.
It is engineered to adhere well to virtually all cable jacketing materials and may be ap-
plied using airless spray equipment or with a brush. Its premium latex binder system is
totally resistant to water and will not re-emulsify after drying.
Physical Properties
• Intumescent – expands with heat
• Water based – for easy installation and cleanup
• Water and weather resistant
• Non-halogenated, no solvents, no asbestos, low VOC content
• Auto bonding – allows fresh sealant to adhere to cured sealant
• Thixotropic – for high-build application
• Flexible
• High solids formula
• Low abrasion – for longer pump life and less maintenance
• Color – white
REF: VOLUME TYPE QUANTITY WEIGHT (KG)
CS105 19.0 L Pail 1 25.00
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
REF: VOLUME TYPE QUANTITY WEIGHT (KG)
SSM106 22.7 L Pail 1 10.90
SSM22B -- Bag 1 10.50
SSM Firestop Mortar
Firestop Mortar is an economical, light-weight cement-based restop product. This pas-
sive material uses a combination of heat sinking and insulating properties to provide a high
level of re resistance.
It is designed to seal through-penetrations, construction gaps or blank openings. It can be
associated with other STI products. Its low density makes re-penetration for retrotting
a simple task.
It is mixed with water and may be applied by pouring, pumping, or troweling.
Firestop Mortar is designed to dry quickly and will not crack or spall due to freezing or
changes in temperature.
Physical Properties
• Low density – easy retrot
• Light weight – less forming and support required
• Fast drying – forms come down faster
• Economical – highest yield per pound means lower installed cost
• Versatile – wide range of applications
• Chemical adhesion – reduces concrete fasteners needs
• Color – pale red
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
12
SSP Intumescent Firestop Putty
SSP Intumescent Putty is a non-hardening compound designed to seal through-pen-
etrations against the spread of re, smoke and toxic gasses. Requiring no tools, it
is soft and pliable and can be installed by hand. Designed to adhere to all common
construction materials.
SSP Intumescent Putty Pads provides the same level of protection for easy
application to electrical boxes or other through-penetrants.
Physical Properties
• Two stage intumescent – fast and aggressive expansion up to 50x
• Soft and pliable – easy installation
• Highly adhesive – allows movement
• Non hardening – easy retrot
• Water resistant
• Endothermic llers – absorbs heat and release water
• Sound insulation (STC 62 ) – excellent sound attenuation properties
• Low VOCs
• Color – red
Smoke N Sound Acoustical Products
Smoke N Sound sealant and spray are high quality acrylic latex products designed
for sealing though-penetrations, linear joints and gaps in smoke rated barriers. This
solution is designed to adhere to virtually all construction surfaces. Its premium latex
binder system is totally resistant to water and will not re-emulsify after drying.
Smoke N Sound sealant may be applied using standard caulking equipment or by
troweling. It has excellent caulking properties on vertical or overhead surfaces
Smoke N Sound spray may be applied using airless spray equipment or with a brush
for small applications or touch ups.
Physical Properties
• Water based – for easy installation and cleanup
• Water resistant
• Paintable
• Non-halogenated, no solvents, no asbestos, low VOC content
• Economical – high performance without the high price
• Low abrasion – for longer pump life and less maintenance
• Thixotropic – for high build application
• Auto bonding – allows fresh sealant to adhere to cured sealant
• Flexible – allows moderate movement (+8%)
• Sound insulation (STC 61)
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
13
REF: VOLUME / DIMENSIONS TypE qUaNTITy WEIGHT (KG)
SSP100 0.6 L Tube 6 1.10
SSP28 0.4 L Tube 1 0.84
SSP4S 184 mm X 184 mm X 5 mm Pad 20 0.27
SSP9S 229 mm X 229 mm X 5 mm Pad 20 0.45
REF: VOLUME TYPE SEaLanT/
SPRaY QUanTITY COLOR WEIGHT (KG)
SNS120W 592 mm Sausage Sealant 12 White 1.00
SNS105 19.0 L Pail Sealant 1 Yellow 33.00
SNS105W 19.0 L Pail Sealant 1 White 33.00
SNS205 19.0 L Pail Spray 1 White 26.00
Ready® Split Sleeve
Ready® Split Sleeve restop pathways are a complete out-of-the-box solution for new
or existing cable penetrations through walls.
Each sleeve kit contains a precut metallic sleeve, mounting plates, intumescent gaskets,
wall warning labels, and the amount of putty required to seal both ends. Each size includes
a unique rolled lip design to eliminate potential sharp edges.
Physical Properties
• Split design for existing cables
• Large plates – cover oversized openings
• Ready to install – no cutting required, no waste
• Smooth entry – no sharp edges
• Economical – material and labor savings
• Locks into place – no supports or clamps required
• No external restop seal required
• Intumescent gasket provided with kit – expansion up to 15x
• Intumescent restop putty provided with kit – expansion up to 8x
Ready® Sleeve
Ready® Sleeve restop pathways are a complete out-of-the-box solution for new cable
penetrations through walls.
Each sleeve kit contains a precut metallic sleeve, mounting plates, intumescent gas-
kets, wall warning labels, and the amount of putty required to seal both ends. Our
51mm and 102mm diameter sleeves include a unique rolled lip design to eliminate
potential sharp edges.
Physical Properties
• Ready to install – no cutting required, no waste
• Smooth entry – no sharp edge
• Economical – material and labor savings
• Locks into place – no supports or clamps required
• No external restop seal required
• Intumescent gasket provided with kit – expansion up to 15x
• Intumescent restop putty provided with kit – expansion up to 8x
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
14
REF: slEEvE sizEs min.
opEning
max.
opEning lEngth platE sizEs quantity wEight (kg)
FSR100 Ø 25 mm Ø 30 mm Ø 57 mm 300 mm 76 mm X 76 mm 4 0.57
FSR200 Ø 51 mm Ø 60 mm Ø 102 mm 300 mm 114 mm X 114 mm 4 1.26
FSR400 Ø 102 mm Ø 114 mm Ø 152 mm 300 mm 203 mm X 203 mm 4 3.28
REF: slEEvE sizEs min.
opEning
max.
opEning lEngth platE sizEs quantity wEight (kg)
FS100 Ø 25 mm Ø 30 mm Ø 32 mm 300 mm Ø 55 mm 6 0.50
FS200 Ø 51 mm Ø 60 mm Ø 65 mm 300 mm Ø 86 mm 6 1.00
FS201 Ø 51 mm Ø 60 mm Ø 65 mm 300 mm Ø 115 mm 6 1.20
FS400 Ø 102 mm Ø 114 mm Ø 114 mm 300 mm Ø 140 mm 1 2.70
FS401 Ø 102 mm Ø 114 mm Ø 114 mm 300 mm Ø 205 mm 1 2.90
FP Intumescent Firestop Plugs
Series FP Intumescent Firestop Plugs are soft and supple foam plugs molded from
polyurethane. Plugs are conveniently sized to t 51 or 102 mm diameter openings or
metallic sleeves.
These plugs are designed to restop single or bundled cables and blank openings. The
intumescent plugs expand when exposed to heat to quickly close o around combus-
tible jacketed cables.
Physical Properties
• Intumescent – expands in all directions up to 10x
• Fast and easy installation – no special tools required
• Reinstallable – soft resilient foam
• Smoke resistant – superior smoke leakage ratings
• Low VOC
• Color – red
15
REF: opEning / slEEvE dimEnsions QUAnTiTY WEigHT (Kg)
FP200 Ø 51 mm 10 0.61
FP400 Ø 102 mm 10 1.25
SSB Intumescent Firestop Pillows
Firestop Pillows are designed to restop through penetrations in wall and oor ap-
plications. These intumescent and highly resilient pillows are installed in openings by
compressing and stacking into the opening in a brick-like fashion. This method of seal-
ing oers easy retrotting of through-penetrants without damaging the restop seal.
Pillows consist of a mineral ber core material sealed with a water resistant intumes-
cent membrane. This coated core material is heat-sealed in a tough, non-irritating,
re-retardant polythene bag.
Physical Properties
• Intumescent – expands in all directions
• Lightweight
• Easy installation – no tools required
• Reinstallable – for easy through-penetrant retrotting
• Good air leakage rating
• Heat sealed poly bag – strong, durable and no irritating berglass
• Low VOC
• Color – red
REF: DIMENSIONS
HEIGHT X LENGTH X THICKNESS QUANTITY WEIGHT (KG)
SSB14 25 mm X 101 mm X 229 mm 20 0.09
SSB24 50 mm X 101 mm X 225 mm 10 0.13
SSB26 50 mm X 152 mm X 225 mm 22 0.16
SSB36 76 mm X 152 mm X 225 mm 16 0.22
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
LCC & RTC Intumescent Firestop Collars
LCC Intumescent Collars are factory-manufactured collars designed to restop plastic
pipes. A molded intumescent insert is set in a galvanized metal collar. LCC collars are
specically sized to t 38mm, 51mm, 76mm and 102mm diameter trade sized pipes.
From a temperature of 160°C, the intumescent insert begins to expand rapidly to com-
pletely seal the through-penetration. The expansion continues up to 538°C.
RTC Intumescent Collars are adjustable collars designed to seal 76mm and 102mm
diameter trade size pipes.
Physical Properties
• Highly intumescent – expansion up to 60x
• Fast expansion – seal o burning penetrants
• Easy installation – quick closure design
• Water resistant – no soluble or hydroscopic ingredients
16
SSC Intumescent Firestop Collars
SSC Intumescent Collars are factory-manufactured collars designed to restop plastic
pipes. A molded intumescent insert is set in a galvanized metal collar.
The insert uses a two-stage intumescent technology, providing a very responsive and
highly directionalized expansion.
From a temperature of 120°C, the intumescent insert begins to expand rapidly to seal
completely the through-penetration. The expansion continues up to 538°C.
Physical Properties
• Two-stage intumescent technology
• Very fast expansion – seal o burning penetrants
• Easy installation – xation design reduces eld labor
• Water resistant – no soluble or hydroscopic ingredients
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
REF: pipE tRadE sizE quantity wEight (kg)
SSC150 Ø 38 mm 6 0.11
SSC200 Ø 50 mm 6 0.14
SSC300 Ø 76 mm 6 0.23
SSC400 Ø 102 mm 6 0.37
SSC600 Ø 152 mm 2 2.12
REF: pipE tRadE sizE quantity wEight (kg)
LCC150 Ø 38 mm 6 0.10
LCC200 Ø 50 mm 6 0.12
LCC300 Ø 76 mm 6 0.23
LCC400 Ø 102 mm 6 0.33
RTC350 Ø 76 mm and Ø 102 mm 6 0.34
SSW Intumescent Firestop Wrap Strip
Intumescent Wrap Strips are highly exible, elastomeric strips designed to restop com-
bustible penetrations. Convenient rolls, or individually sized strips facilitate installation
and minimize waste.
These products utilize an intumescent technology, providing very responsive and highly
directionalized expansion. Their fast expansion provides quick closure of burning com-
bustible penetrants.
From a temperature of 120°C, the intumescent strip begins to expand rapidly to seal
completely the through-penetration. The expansion continues up to 538°C.
Physical Properties
• Highly intumescent – expansion up to 60x
• Fast expansion – seal o burning penetrants
• Water resistant – no soluble or hygroscopic ingredients
• Easy installation – soft and exible, less strip and less fasteners required
• Economical – rolls or precut strips means no piecing, less waste
• Versatile solution – for a wide range of applications
REF: TYPE DIMENSIONS
LENGTH X HEIGHT X THICKNESS PIPE SIzE quaNTITY wEIGHT (KG)
SSWBLU2 Wrap Strip Roll 3.7 m X 51 mm X 3.2 mm -- 8 0.72
SSWRED2 Wrap Strip Roll 3.7 m X 38 mm X 3.2 mm -- 8 0.52
SSWBLU220 Wrap Strip Precut 20 mm X 38 mm X 3.2 mm Ø 52 mm 25 0.05
SSWBLU230 Wrap Strip Precut 284 mm X 76 mm X 3.2 mm Ø 76 mm 25 0.10
SSWBLU240 Wrap Strip Precut 356 mm X 102 mm X 3.2 mm Ø 102 mm 25 0.14
Wrap Strip
REF: lEngth pipE sizE to bE usEd with quantity wEight (Kg)
SSWRC 7.6 m -- SSWBLU2 1 2.30
SSWRC2 7.6 m -- SSWRED2 1 1.70
WSC-8 -- Ø 152 mm and Ø 203 mm SSWBLU2 1 0.69
WSC-8RED -- Ø 152 mm SSWRED2 1 0.48
WSC-12 -- Ø 254 mm and Ø 305 mm SSWBLU2 1 0.91
Metal Restraining Collar
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
17
Ready® Firestop Grommet
Ready® Firestop Grommet is a molded, two-piece grommet with an integral re and
smoke sealing foam membrane. It is designed to seal individual cable penetrations
against re and smoke through framed wall assemblies.
A soft foam inner core conforms to the cable to form a tight seal. Grommet snaps
together around cable and locks tightly into the wall.
Physical Properties
• Easy restop solution
• Smoke seal
• Split design – for previously installed cables
• Made with Ultem® premium, plenum grade material – exceptional ame and heat resistance
• Designed for gypsum wall
• No sleeve, no sealant required
• Color – red
REF: lEngth REquiREd
opEning
max cablE
diam.
quantity pER
blistER
quantity pER
pack wEight (g)
RFG1 41 mm Ø 14 mm Ø 7 mm 10 Grommets 10 Blisters 5
Cast-In Firestop Device
Cast-In Firestop Devices consist of molded plastic sleeves incorporating an intumes-
cent restopping system and a exible smoke and water resistant seal. It has been
engineered for use in concrete oors to restop openings for various combustible and
non-combustible penetrants.
The molded plastic body can be easily cut as required to accommodate concrete
thickness. Steel deck kits are available to facilitate installation in uted metal decks as
well as extension tubes for thicker oors.
Physical Properties
• Easy installation – eliminates core drilling
• Water and smoke resistant gasket
• Intumescent material already incorporated in the device
• Available in four diameters
• Saves time – no restopping step required
• Can be easily cut to adapt the length
• Metal deck kit for installation over steel deck
• Extension tube for concrete greater thicker than 204mm
REF: pipE
sizE FootpRint min. stEEl
dEck opEning qty wEight
(kg)
Devices for combustible and noncombustible penetrants (Red Device)
CD200 Ø 51 mm 131 mm X 131 mm Ø 93 mm 6 0.50
CD300 Ø 76 mm 146 mm X 146 mm Ø 108 mm 6 0.60
CD400 Ø 102 mm 172 mm X 172 mm Ø 134 mm 6 0.75
CD600 Ø 152 mm 229 mm X 229 mm Ø 184 mm 6 1.10
Devices for noncombustible penetrants (Black Device)
CD200M Ø 51 mm 131 mm X 131 mm Ø 93 mm 6 0.50
CD300M Ø 76 mm 146 mm X 146 mm Ø 108 mm 6 0.60
CD400M Ø 102 mm 172 mm X 172 mm Ø 134 mm 6 0.75
CD600M Ø 152 mm 229 mm X 229 mm Ø 184 mm 6 1.10
REF: pipE
sizE qty wEight
(Kg)
Extension Tubes
CD200X Ø 51 mm 6 0.16
CD300X Ø 76 mm 6 0.19
CD400X Ø 102 mm 6 0.21
CD600X Ø 152 mm 6 0.29
Metal Deck Adapters
CD200DK Ø 51 mm 6 0.20
CD300DK Ø 76 mm 6 0.32
CD400DK Ø 102 mm 6 0.40
CD600DK Ø 152 mm 6 1.15
Tub Box Kit
CD200T Ø 51 mm 1 1.15
REF: pipE tRadE sizE quantity wEight (kg)
CS1628 41 cm X 71 cm 1 2.72
CS2436 61 cm X 92 cm 1 5.00
CS3636 92 cm X 92 cm 1 7.26
CS3641 92 cm X 104 cm 1 7.71
CS2852 71 cm X 132 cm 1 8.62
Composite Sheet
The intumescent Composite Sheet is a lightweight, rigid restop panel consisting of an
intumescent layer bonded to a galvanized steel sheet reinforced with steel wire mesh
covered with aluminum foil. It is designed to seal medium to large size openings with
a variety of dierent penetrants. When exposed to temperatures in excess of 177°C,
Composite Sheet expands minimum 15x to form a dense insulative char that mini-
mizes heat transfer.
Physical Properties
• Highly intumescent – expands up to 15x
• Lightweight – easy handling and less hanging weight
• Easy to cut – using simple sheet metal tools
• Hole reduction – reduce large openings
• Versatile solution – wide range of applications
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
18
FyreFlange™ Firestop Angle
FyreFlange™ Firestop Angles consist of galvanized steel retaining angles with a layer
of bonded intumescent material designed to be installed around the perimeter of non-
dampered rectangular steel ducts. It can be installed as the duct is installed and in-
spected just once after the installation is complete.
In the event of re, FyreFlange™ Firestop Angles prevent duct collapse and minimize
deection. When exposed to temperatures in excess of 177°C, its intumescent system
expands to form a dense insulative char that stops the spread of re and minimizes
heat transfer.
Physical Properties
• Intumescent gaskets – expands to 15 times
• Economical – Saves labor
• Easy installation
• Versatile – use for insulated and non insulated ducts
• Can be installed over or under duct insulation
• No additional restop materials required
• Easy identication and inspection
• Color – red
REF: DEsignation DiMEnsions quantity WEigHt (Kg)
FFA2208 Firestop Angle 51 mm X 51 mm X 244 cm 6 1.93
FFC22 Corner Clips -- 8 per bag 0.37
FFS22 Splice Pack -- 6 per bag 0.32
REF: dimEnsions quantity wEight (kg)
EP44 9.5 cm X 9.5 cm X 0.32 cm 20 0.04
EP45 10.8 cm X 10.8 cm X 0.32 cm 20 0.07
PowershieldTM Electrical Box Inserts
Powershield electrical box insert is a one-component pad designed to provide passive
smoke and re protection in electrical switch or receptacle boxes.
The intumescent insert has been designed to install inside the box, directly against the
back wall. It features an adhesive strip applied to the back of the pad to ensure adhe-
sion to the back of an electrical box.
Physical Properties
• Highly intumescent – Expands up to 24x
• Rapid expansion – seal o passage of re and smoke quickly
• Water resistant – no soluble or hygroscopic ingredients
• Easy installation – just peel and stick it inside of box
• One step installation – saves time and labor
• Easy retrot
• No clean-up required – no mess, no residue
• Thin prole to maximize area inside box
• Sound insulation (STC 64 ) – excellent sound attenuation properties
• Non-conductive liner face – safe for use inside box
• Color – red
19
Maximum Fire & Smoke Protection
• Maximum resistance to re and smoke whether
empty or 100% visually lled.
• Assures re and smoke protection with every
new or retrot cable installation.
• Superior re and smoke leakage vs. standard
sleeve and putty systems.
• Unlike conventional sleeve and putty systems,
EZ-Path® remains re and smoke compliant
100% of the time.
Fast-Acting Intumescent Material
• Engineered for rapid expansion when exposed
to re or high temperatures.
• Intumescent material responds to ames or
heat by quickly sealing the pathway and pre-
venting the passage of ames and smoke.
• Innovative built-in restop design assures it
is restopped and smoke-sealed — even at
maximum cable loading.
No Firestopping Required
• Built-in restopping system automatically
adjusts to the number of cables installed.
• Design assures it is restopped at all stages of use.
• Mechanical application eliminates the use of
sealant, putty and other products that need to
be removed and replaced.
20
In
itial Install
Performance
• UL® Classied and FM Approved in accor-
dance with ASTM E814 (UL1479).
• UL systems are available for up to 4 hour rated
oor and wall constructions.
• Tested according to EN 1366, DIN 4102 & BS 476.
• Test and approved for marine applications.
• Empty or full, EZ-Path® is continuously code
compliant — 100% of the time.
• Tested and approved cable capacities range
from 0 to 100% visual ll.
• U.S. Patent 6,732,481
Specications
All data, video, and communications cable bundles
shall utilize an enclosed re rated pathway device
wherever said cables penetrate rated walls. The
re-rated pathway shall contain a built-in re seal-
ing system sucient to maintain the hourly re rating
of the barrier being penetrated. The self-contained
sealing system shall automatically adjust to the in-
stalled cable loading and shall permit cables to be
installed, removed, or retrotted without the need to
adjust, remove or reinstall restop materials.
Pays For Itself In A Few Cable Changes
• All-in-one design installs in minutes.
• Conveniently packaged kits for easy installation
— no additional parts to order.
• Splits apart for old work.
• Clean, professional, engineered appearance.
• Easy moves, adds and changes.
• Can be installed as the wall is being built.
E
N
1
3
6
6
•
D
I
N
4
1
0
2
•
B
S
4
7
6
•
21
Initial Install
Cat No. EZG1644
Capacity: 16 Pathways
Modular Floor Grid System
An EZ-Path® Solution for High Volume Cable
Penetrations through Floors
Now there is a bolt-in solution for riser applications
that brings the safety and simplicity of EZ-Path® to
your vertical cable installations.
The EZ-Path® Modular Floor Grid System can handle
literally thousands of cables.
Modular Floor Grid Systems utilize the high volume,
EZ-Path® Series 44 Pathways installed in banks
of four to provide your cabling systems with room
to grow. Sturdy steel grids mount one, two or four
banks of pathways in built-in slots for a total of up
to sixteen pathways through a single oor opening.
A single bank Floor Grid comes complete with Path-
ways. Multi-bank Modular Floor Grids are installed
with restop panels sealing each slot. As additional
cable capacity is required, restop panels are re-
moved and pathway modules containing four path-
ways are installed in each slot.
Cat No. EZD444
Capacity: 4 Pathways
Sold complete with grid
and pathways
Cat No. EZG844
Capacity: 8 Pathways
22
SERIES 22 SERIES 33 SERIES 44
Height X Width 38 mm X 38 mm 76 mm X 76 mm 102 mm X 102 mm
Length 267 mm 267 mm 267 mm
Can Be Ganged Up to 3 Up to 7 Up to 5 in walls
Up to 16 in oors
Can Be Lengthened -- 152 mm increments --
Insert Into Cored Hole 51 mm 102 mm 153 mm
Fire Rated In Walls / Floors Up to 4 Hour Up to 4 Hour Up to 4 Hour
Approx. Max Cable Capacity 25 +120 +244 +
Approx. Max Cable Capacity (Ganged) 75 +840 +1220 +
Approx. Max Cable Capacity
(Grid) -- -- 3904 + in oors
Ref: DescRiption qty Weight (Kg)
EZ-Path® Series 22 Fire Rated Pathway Kits
EZD22 22 Series - Fire-Rated Pathway Device Kit 6 0.91
EZ-Path® Series 33 Fire Rated Pathway Kits
EZD33FWS Series 33 - Fire-Rated Pathway Device 6 1.22
EZD33E Series 33 - Extension Module 1 0.68
EZP133W Series 33 - Single Square Wall Plate Pack 1 0.20
EZP133CW Series 33 - Single Circular Wall Plate Pack 1 0.37
EZP233W Series 33 - Double Wall Plate Pack 1 0.32
EZP333W Series 33 - Triple Wall Plate Pack 1 0.47
EZP433W Series 33 - Four-Gang Plate Pack 1 0.88
EZP733W Series 33 - Seven-Gang Plate Pack 1 1.15
EZP133K Series 33 - Single Kick-In Plate Pack - (For use with oor applications) 6 0.31
EZP133R Series 33 - Retro-Fit Mounting Plate Pack 1 1.58
EZP133CA Series 33 - Conduit Attachment Plate Pack 1 0.41
RCM33 Series 33 - One Pair (2) Radius Control Modules 1 0.02
EZ-Path® Series 44 Fire Rated Pathway Kits
EZD44 Series 44 - Fire-Rated Pathway Device 4 3.04
EZDG444 Series 44 - Single Bank Floor Grid - Four (4) Devices With Floor Frame 1 18.60
EZD444MB Series 44 - Single Bank of Devices - Four (4) Devices With Hanger Bracket 1 13.16
EZP144W Series 44 - Single Wall Plate Pack 1 1.00
EZP544W Series 44 - Multi Gang Wall Plate Pack 1 1.82
EZP144F Series 44 - Split Floor Plate Pack 10.69
EZG844 Series 44 - Multi Slot Frame For Eight (8) Pathways 17.26
EZG1644 Series 44 - Multi Slot Frame For Sixteen (16) Pathways 1 12.03
23