Electrical Sector Solutions
Electrical14:
Sector
Volume
FusesSolutions

Volume 14:

Fuses

Available in electronic format only. Publication No. CA08100016E / MSC

www.comoso.com

Volume 14—Fuses
Tab 1—Fuses General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V14-T1-1
Tab 2—Expulsion Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V14-T2-1
Tab 3—Current Limiting Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V14-T3-1
Appendix 1—Eaton Terms & Conditions . . . . . . . . . . . . . . . . . . . . . . . . V14-A1-1
Appendix 2—Superseded Style Number Index. . . . . . . . . . . . . . . . . . . V14-A2-1
Appendix 3—Catalog Number/Style Number Cross Reference . . . . . V14-A3-1

www.comoso.com

14

Copyright
Dimensions, Weights and Ratings
Dimensions, weights and ratings given in this catalog are approximate and should not
be used for construction purposes. Drawings containing exact dimensions are available
upon request. All listed product specifications and ratings are subject to change without
notice. Photographs are representative of production units.

Terms and Conditions
All prices and discounts are subject to change without notice. When price changes
occur, they are published in the Eaton Corporation Price and Availability Digest (PAD).
All orders accepted by Eaton’s electrical sector are subject to the general terms and
conditions as set forth in Appendix 1—Eaton Terms & Conditions.

Technical and Descriptive Publications
This catalog contains brief technical data for proper selection of products. Further
information is available in the form of technical information publications and illustrated
brochures. If additional product information is required, contact your local Eaton
Products Distributor, call 1-800-525-2000 or visit our Web site at www.eaton.com.

Compliance with Nuclear Regulation 10 CFR 21
Eaton products are sold as commercial grade products not intended for application in
facilities or activities licensed by the United States Nuclear Regulatory Commission for
atomic purposes, under 10 CFR 21. Further certification will be required for use of these
products in a safety-related application in any nuclear facility licensed by the U.S.
Nuclear Regulatory Commission.

WARNING
The installation and use of Eaton products should be in accordance with the provisions
of the U.S. National Electrical Code® and/or other local codes or industry standards that
are pertinent to the particular end use. Installation or use not in accordance with these
codes and standards could be hazardous to personnel and/or equipment.

These catalog pages do not purport to cover all details or variations in equipment, nor to provide for
every possible contingency to be met in connection with installation, operation or maintenance.
Should further information be desired or should particular problems arise which are not covered
sufficiently for the purchaser’s purposes, the matter should be referred to the local Eaton Products
Distributor or Sales Office. The contents of this catalog shall not become part of or modify any prior
or existing agreement, commitment or relationship. The sales contract contains the entire
obligation of Eaton’s electrical sector. The warranty contained in the contract between the parties
is the sole warranty of Eaton. Any statements contained herein do not create new warranties or
modify the existing warranty.

Copyright ©201, Eaton Corporation, All Rights Reserved.

www.comoso.com

Introduction

Eaton Corporation is a global leader in power distribution, power quality,
control and automation, and monitoring products.
At Eaton, we believe a reliable, efficient and safe power system is the foundation of every
successful enterprise. Through innovative technologies, cutting-edge products and our highly
skilled services team, we empower businesses around the world to achieve a powerful advantage.
In addition, Eaton is committed to creating and maintaining powerful customer relationships built
on a foundation of excellence. From the products we manufacture to our dedicated customer
service and support, we know what’s important to you.

Solutions
Eaton takes the complexity out of power systems management with a holistic and strategic
approach, leveraging our industry-leading technology, solutions and services. We focus on
the following three areas in all we do:
●

Reliability—maintain the
appropriate level of power
continuity without
disruption or unexpected
downtime

●

Efficiency—minimize
energy usage, operating
costs, equipment footprint
and environmental impact

●

Safety—identify and
mitigate electrical hazards
to protect what you value
most

Using the Eaton Catalog Library
As we grow, it becomes increasingly difficult to include all products in one or two comprehensive
catalogs. Knowing that each user has their specific needs, we have created a library of catalogs for our
products that when complete, will contain 14 volumes. Since the volumes will continuously be a work
in progress and updated, each volume will stand alone. Refer to our volume directory, MZ08100001E,
for a quick glance of where to look for the products you need. The 14 volumes include:
●

●

●

●

●

Volume 1—Residential
and Light Commercial
(CA08100002E)
Volume 2—Commercial
Distribution (CA08100003E)
Volume 3—Power
Distribution and Control
Assemblies (CA08100004E)
Volume 4—Circuit
Protection (CA08100005E)
Volume 5—Motor Control
and Protection
(CA08100006E)

●

●

●

●

●

Volume 6—Solid-State
Motor Control
(CA08100007E)
Volume 7—Logic Control,
Operator Interface and
Connectivity Solutions
(CA08100008E)
Volume 8—Sensing
Solutions (CA08100010E)
Volume 9—Original
Equipment Manufacturer
(CA08100011E)
Volume 10—Enclosed
Control (CA08100012E)

●

●

●

●

Volume 11—Vehicle and
Commercial Controls
(CA08100013E)
Volume 12—Aftermarket,
Renewal Parts and Life
Extension Solutions
(CA08105001E)
Volume 13—Counters,
Timers and Tachometers
(CA08100015E)—Available
in electronic format only
Volume 14—Fuses
(CA08100016E)—Available
in electronic format only

These volumes are not all-inclusive of every product, but they are meant to be an overview
of our product lines. For our full range of product solutions and additional product information,
consult Eaton.com/electrical and other catalogs and product guides in our literature library.
These references include:
●

The Consulting Application
Guide (CA08104001E)

●

The Eaton Power Quality
Product Guide (COR01FYA)

If you don’t have the volume that contains the product or information that you are looking for,
not to worry. You can access every volume of the catalog library at Eaton.com/electrical in the
Literature Library.
By installing our Automatic Tab Updater (ATU), you can be sure you always have the most recent
version of each volume and tab.

Volume 14—Fuses CA08100016E—February 2012

www.comoso.com

www.eaton.com

i

Introduction

Icons
Green Leaf
Eaton Green Solutions are products, systems or solutions that represent Eaton
benchmarks for environmental performance. The green leaf symbol is our
promise that the solution has been reviewed and documented as offering
exceptional, industry-leading environmental benefits to customers, consumers
and our communities. Though all of Eaton's products and solutions are
designed to meet or exceed applicable government standards related to
protecting the environment, our products with the Green Leaf designation
further provide “exceptional environmental benefit”.

Learn Online
When you see the Learn Online icon, go to Eaton.com/electrical and search for
the product or training page. There you will find 100-level training courses,
podcasts, webcasts or games and puzzles to learn more.

Drawings Online
When you see the Drawings Online icon, go to Eaton.com/electrical and find the
products page. There you will find a tab that includes helpful product drawings
and illustrations.

Contact Us
If you need additional help, you can find contact information
under the Customer Care heading of Eaton.com/electrical.

ii

Volume 14—Fuses CA08100016E—February 2012 www.eaton.com

www.comoso.com

Fuses General
Current Limiting Fuses

1.1

Product Overview
Power Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power vs. Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low vs. Medium vs. High Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Expulsion vs. Current Limiting (Definitions per ANSI C47.40-1993). . .
Current Limiting Fuse Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Fuse Component Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V14-T1-2
V14-T1-2
V14-T1-2
V14-T1-3
V14-T1-3
V14-T1-3

1
1
1
1
1
1
1
1
1
1

Expulsion Fuses

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T1-1

1.1
1

Fuses General
Product Overview

Contents

Typical Eaton Fuses

Description

1

Page

Current Limiting Fuse Types . . . . . . . . . . . . . . . . .
Expulsion vs. Current Limiting
(Definitions per ANSI C47.40-1993). . . . . . . . . . .
General Fuse Component Terms . . . . . . . . . . . . . .

1

V14-T1-3
V14-T1-3
V14-T1-3

1
1
1
1
1
1
1
1

Product Overview

1

Power Fuse

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Power vs. Distribution

Eaton’s roots in the
medium voltage power
fuse business began
over 75 years ago under
Westinghouse® Electric.
In 1935, Westinghouse
introduced the medium
voltage boric acid expulsion
fuse followed by the medium
voltage current limiting fuse.
Even today, medium voltage
fuses continue to use that
core technology. Eaton
continues to build on
the technology legacy
by engineering high
performance, cost-effective
power fuse products.
Eaton’s medium voltage
fuses are manufactured and
tested to the requirements
of the C37-4X series of
standards that are maintained
and updated regularly to
maintain currency with
industry practices. These
standards are:
IEEE Std. C37.40 ™
IEEE Standard Service
Conditions and Definitions
for High Voltage Fuses,
Distribution Enclosed SinglePole Air Switches, Fuse
Disconnecting Switches,
and Accessories (ANSI).

IEEE Std. C37.41 ™
IEEE Standard Design
Tests for High-Voltage
(>1000V) Fuses, Fuse and
Disconnecting Cutouts,
Distribution Enclosed SinglePole Air Switches, Fuse
Disconnecting Switches, and
Fuse Links and Accessories
used with These Devices
(ANSI).

IEEE Std. C37.47™
IEEE Standard Specifications
for High Voltage Current
Limiting Type Distribution
Class Fuses and Fuse
Disconnecting Switches.

IEEE Std. C37.42 ™
IEEE Standard Specifications
for High-Voltage (>1000V)
Expulsion-Type DistributionClass Fuses, Fuse and
Disconnecting Cutouts,
Fuse Disconnecting
Switches, and Fuse Links,
and Accessories used with
These Devices (ANSI).

IEEE Std. C37.48 ™
IEEE Guide for the
Application, Operation, and
Maintenance of High Voltage
Fuses, Distribution Enclosed
Single-Pole Air Switches,
Fuse Disconnecting
Switches, and Accessories
(ANSI).

IEEE Std. C37.46™
IEEE Standard Specifications
for High Voltage Expulsion
and Current Limiting Type
Power Class Fuses and Fuse
Disconnecting Switches.

The following IEEE standards
are also applicable to the fuse
products covered in this
publication:

IEEE Std. C37.48.1 ™
IEEE Guide for the
Classification, Application,
and Coordination of CurrentLimiting Fuses with Rated
Voltages 1–38 kV.
A better understanding of
some fuse terminology will
help you understand and
select the correct fuse. The
following is a brief overview
of those terms.

1
1
V14-T1-2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

The differentiation is intended
to indicate the test conditions
and where fuses are normally
applied on an electrical
system, based on specific
requirements for generating
sources, substations and
distribution lines. Each
class has its own unique
set of voltage, current and
construction requirements
(see C37.42, .46 and .47).

Low vs. Medium vs.
High Voltage
While fuses are defined in
the ANSI standards as either
low or high voltage, Eaton
has elected to name their
fuses to correspond with the
equipment in which they are
installed. Therefore, per ANSI
C84, our fuses are named
as follows:
●

●

●

Low voltage—1000V and
below
Medium voltage—greater
than 1000 to 69,000V
High voltage—greater than
69,000V

Fuses General
Product Overview

Expulsion vs. Current
Limiting (Definitions per ANSI
C47.40-1993)

1.1
1

General Fuse Component Terms

An expulsion fuse is a vented
fuse in which the expulsion
effect of the gases produced
by internal arcing, either
alone or aided by other
mechanisms, results in
current interruption.

Backup Fuses
A fuse capable of interrupting
all currents from the
maximum rated interrupting
current down to the rated
minimum interrupting
current.

A current limiting fuse is a
fuse that, when its current
responsive element is melted
by a current within the fuse’s
specified current limiting
range, abruptly introduces
a high resistance to reduce
current magnitude and
duration, resulting in
subsequent current
interruption. Refer to Fuse
Types Protection Range
figure below for a features
comparison.

Backup fuses are always
used in a series with another
interrupting device capable of
interrupting currents below
the fuse’s minimum
interrupting current.

An expulsion fuse is not
current limiting and as a
result limits the duration of a
fault on the electrical system,
not the magnitude.

General Purpose fuses are
typically used to protect
feeders and components
such as transformers.

Current Limiting Fuse Types

Full Range Fuses
A fuse capable of interrupting
all currents from the rated
interrupting current down
to the minimum continuous
current that causes melting
of the fusible element,
with the fuse applied at
the maximum ambient
temperature specified by
the manufacturer.

General Purpose Fuses
A fuse capable of interrupting
all currents from the rated
interrupting current down
to the current that causes
melting of the fusible element
in no less than one hour.

There are three current
limiting fuse types: Backup,
General Purpose and Full
Range. It is important that the
user have an understanding
of these definitions to ensure
proper application of the fuse
(see Fuse Types Protection
Range figure below).

General High Voltage Fuse Comparison
Expulsion

Current Limiting

Vented

Sealed

Electromechanical

Static

Interrupts at current zero

Limits fault current

Generally higher voltage and current application
capabilities

Generally higher interrupting ratings

Different time/current characteristics

Different time/current characteristics

Fuse Types Protection Range

Fuse Refill Unit (of an
Expulsion Fuse)
A fuse refill unit is a
replaceable assembly
containing the calibrated
current-responsive fuse
element and certain other
items that facilitate current
interruption. On its own, the
refill unit has no interrupting
ability. A refill unit must be
mounted in a fuse holder with
a spring assembly to form a
refillable fuse unit. The refill
unit is the section of the fuse
that must be replaced after a
fuse operation.
Fuse Holder (of an
Expulsion Fuse)
A fuse holder is a reusable
holder that when equipped
with a fuse refill unit forms
a fuse unit, capable of
interrupting an overload or
fault current. A fuse holder
is supplied with a spring and
shunt assembly, necessary
to complete the internal
interrupting assembly. The
spring and shunt assembly is
supplied with the fuse holder
but is also available as a
replacement part, as it may
need replacement after
several of heavy operations.
Fuse Unit
A fuse unit is a replaceable
unit or assembly that is
able, on its own, to perform
current interruption. In
the case of a refillable fuse
unit, the refill unit must
be replaced after a fuse
operation. Where a complete
fuse unit is supplied from the
factory, the complete fuse
unit must be replaced after a
fuse operation. All currentlimiting fuses are fuse units.

Exhaust Control Device
When expulsion fuses are
used in enclosures, exhaust
control devices (filters,
condensers or mufflers) are
used to control the sound
of the fuse operation, and
to de-ionize and absorb the
fuse exhaust products. These
devices are normally supplied
separately, because of
different characteristics and
ratings. They are reusable but
may need replacement after
several heavy operations.
Mounting
A mounting provides all the
necessary parts to safely
mount a fuse in its intended
piece of equipment. The
base is the metal support to
which all other pieces attach.
Insulators attach to the base
and insulate the live fuse unit
from the base and everything
beyond the base. Live parts
are the parts of the mounting
that are energized once
electricity is flowing. The live
parts provide the means to
hold the fuse unit in place,
electrical contact, and a
place to make line and load
connections.
Non-Disconnect Mounting
A non-disconnect mounting
does not provide a means for
removing the fuse unit until
the circuit is dead and the
fuse unit can be removed
manually. The fuse unit is
held in place by friction
through the use of fuse
clips or by a cross bar.

Current Limiting Type

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

BACKUP

1

GENERAL PURPOSE

1

FULL RANGE

i hr.

1

1

i max. — Maximum rated interrupting current
i min. — Minimum rated interrupting current
i hr. — Current causing element melting in 1 hour
i — Any current melting element with no time limit

i

1

i min.

1

i max.

1

Interrupting Current

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-T1-3

1.1
1
1
1
1
1
1
1
1
1
1

Fuses General
Product Overview

Disconnect Mounting
The disconnect mounting
allows the fuse unit to be
removed (off load) using an
insulated switch stick. The
switch stick grabs a pull ring
and disconnects the fuse unit
that may then be lifted out of
its mounting.
Dropout Mounting
Dropout mountings are
used in outdoor applications.
The fuse unit is equipped
with a mechanical trigger that
unlatches the upper contact,
allowing the fuse unit to drop
out, increasing the dielectric
separation, and providing
visible indication of a
blown fuse.

Live Parts
Live parts were briefly
discussed as part of the
“Mounting” definition.
Everything above the
insulators on the mounting
excluding the fuse unit, fuse
holder, and the fuse end
fittings (if required) are
considered the live parts. Fuse
end fittings are discussed
next and are not required
with non-disconnect live
parts, but are required and
included with disconnect live
parts. Live parts may be sold
separately as replacement
parts or for new OEM
applications.

End Fittings
End fittings are metal parts
that attach to each end of a
fuse unit’s ferrules (end caps).
As previously mentioned,
they are used solely with
disconnect fuse applications
or when converting a nondisconnect to a disconnect
fuse configuration.
When end fittings are
ordered, a fitting for each end
of the fuse is included. Keep
in mind that end fittings can
become damaged in use and,
therefore, are sold separately
from the live parts when
necessary. It is not necessary
to purchase an entire set of
live parts when only the end
fittings are required.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V14-T1-4

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
Eaton Expulsion Fuses

2.1

Product Overview
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Refillable and Replaceable Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outdoor Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.2

V14-T2-4
V14-T2-5
V14-T2-7
V14-T2-9

2
2
2
2
2
2

V14-T2-12
V14-T2-19

2
2

V14-T2-20
V14-T2-21
V14-T2-21
V14-T2-22

V14-T2-27

2
2

V14-T2-32
V14-T2-32
V14-T2-33

DBU Type Fuses
V14-T2-39
V14-T2-39
V14-T2-40
V14-T2-41
V14-T2-43
V14-T2-43
V14-T2-44
V14-T2-44
V14-T2-45
V14-T2-50

RBA and RDB Type Fuses
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
2

DBA Type Fuses

Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interruption and Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Testing and Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.7

V14-T2-3

BA Type Fuses

Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.6

V14-T2-3

2

2

Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.5

V14-T2-2

Application
Transformer Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Repetitive Faults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.4

V14-T2-2

Fuse Selection
Voltage Rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupting Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous Current Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Coordination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.3

V14-T2-2

V14-T2-52
V14-T2-52
V14-T2-53
V14-T2-53

2
2
2
2
2
2
2
2
2
2
2
2

V14-T2-58
V14-T2-59
V14-T2-60
V14-T2-68

2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-1

2.1
2

Expulsion Fuses
Product Overview

Contents

Eaton Expulsion Fuses

Description

2

Page

Catalog Numbers . . . . . . . . . . . . . . . . . . . . . . . . . .
Refillable and Replaceable Fuses. . . . . . . . . . . . . .
Outdoor Applications . . . . . . . . . . . . . . . . . . . . . . .

2

V14-T2-2
V14-T2-3
V14-T2-3

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Product Description
Eaton’s expulsion fuses use
boric acid as the interrupting
medium. Under a fault
condition, arc heat
decomposes the boric acid
into water vapor. The water
vapor blast de-ionizes the arc
path preventing arc re-ignition
after a natural current zero.
RBA type indoor expulsion
fuses must be fitted with a
discharge filter or condenser,
that moderates the discharge
exhaust. The discharge filter
limits the exhaust to a small
and relatively inert amount of
gas and lowers the noise
level without affecting the
fuse interrupting rating.
Steam discharge, that can
effect the interrupting, is fully
restricted by the condenser.

DBU type fuse units are
designed for new and
aftermarket utility applications.
End fittings are available, in
both indoor and outdoor
versions, as well as live parts
and mountings. Mufflers
confine the arc within the fuse
and substantially reduce the
noise and exhaust when the
fuse interrupts.
RBA E-Rated Refillable
Boric Acid

Catalog Numbers
Each Eaton fuse product is
identified by a unique
descriptive catalog number
that contains major
information such as the fuse
family and item, and rated
maximum continuous current
and rated maximum
application voltage where
applicable. The catalog
number does not change
where form, fit and function
remain unchanged, although
the associated Eaton internal
10 character style number
may change. Fuse products
should be ordered by the
descriptive catalog number.

Mountings
Mountings include a base,
porcelain or glass polyester
insulators, and live parts.
They help enable the fuse to
be safely attached to the
gear. Mountings can be
either disconnect, nondisconnect or dropout. Nondisconnect mountings are
available in bolt-on or clamptype arrangements. Fuses
may be vertical or underhung.

Live Parts

RDB E-Rated Refillable
Outdoor Dropout Boric
Acid

RDB type outdoor dropout
fuses include an ejector
spring that forces the arcing
rod through the top of the
fuse. The arcing rod strikes a
latch on the mounting that
forces the fuse to swing
outward through a 180° arc
into the dropout position.
Refill units can be field
installed into RBA and RDB
expulsion fuses. Once the
operated unit has been
removed, the separately
purchased unit can be easily
installed into the fuse holder.

Accessories
The following accessories are
available for expulsion fuses:

Live parts attach the fuse to
the insulators and are
considered part of the
mounting. All parts above the
insulators are live parts.

End Fittings
End fittings are metal parts
that attach to each end of the
fuse at the ferrules. They are
used only on disconnect
fuses or when converting a
non-disconnect to a
disconnect fuse.
DBU Dropout Boric Acid—
for Use Indoors, Inside
Switchgear or Outdoors

2
V14-T2-2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
Product Overview

Refillable and Replaceable Fuses

Outdoor Applications

rating. A discharge filter is
available that restricts
discharge but not to a level
that causes a reduction in the
interrupting rating. A high
capacity discharge filter is
also available, but its use is
restricted to certain
applications on 15.5 kV
equipment at maximum
voltages below 14.4 kV. This
device allows a higher
interrupting rating, but allows
more discharge.

Boric acid expulsion power
fuses are divided into two
types, refillable and
replaceable.
Refillable fuses are
constructed so that the
consumable refill unit can be
removed and replaced after a
fuse operation. Because the
fuse holder and spring and
shunt assembly components
are reused, they can be
constructed with a heavy
duty design that also allows
the unit to have a high
interrupting capacity.
Because these components
are reused it is easy to
change fuse current rating by
simply changing the refill unit.

The outdoor refillable fuse is
the RDB (Refillable Dropout
Boric acid) fuse. RDB fuses
cannot be equipped with
exhaust control devices.
The construction of the RDA
and RDB is similar. They both
utilize RBA refill units. The
main difference in the internal
construction is the ballistic
kick-out pin that initiates the
dropout action. Externally the
RBD outdoor fuse holder
tube has a protective coating
of tough epoxy paint that
provides ultraviolet
protection. The fuse holder
has a sealed weatherproof
design.

The indoor refillable fuse is
the RBA (Refillable Boric
Acid) fuse. It is designed to
be used indoor or in an
enclosure with an exhaust
control device that limits the
discharge given off by the
fuse during operation. Three
types of exhaust control
devices are available to limit
the discharge. A condenser
may be used that fully
restricts the discharge but
reduces the interrupting

Typical Discharge Pattern from an Eaton Outdoor Boric Acid
Power Fuse
Vent
End
of Fuse
Intense
Discharge
up to
3 Feet

Innocuous
Gases

Innocuous
Gases
Clouds of Water Vapor
up to 6 Feet
Vapor Clouds
May Rebound From Ground
Extending to 10 Feet

2.1

A complete fuse consists of a
fuse mounting, a fuse holder
that includes the spring and
shunt assembly, a refill unit,
and an exhaust control device
for indoor applications. These
parts are shown in the RBA/
RDB section.
Both disconnect and nondisconnect mountings are
available for RBA fuses. Each
of these mountings has front
connected terminals. Indoor
non-disconnect fuse holders
have translucent tubes, and
the lower end of the spring
and shunt assembly is
equipped with a bright orange
cap to give a visual indication
of fuse operation. RDB
outdoor mountings must be
disconnecting because of the
dropout requirement to
provide dielectric isolation
and visible indication.
BA type installations were
made obsolete several years
ago, but BA refill units are still
available to enable re-fusing
in existing applications. BA
and RBA installations use the
same exhaust control
devices. RBA filters or
condensers can be used to
replace BA filters or
condensers if required.
Replacement BA mountings
and fuse holders are not
normally available.
Replaceable fuses have a
lower initial installed cost by
providing a more cost
effective construction.
Replaceable fuses generally
offer faster reconnection, but
with higher replacement cost
and lower interrupting
ratings.
Eaton offers a replaceable
style DBU fuse for either
indoor or outdoor
applications. DBU fuses are
lighter, less expensive fuses
than the higher rated RBA/
RBD fuses. DBA fuse units
are offered as replacement
fuses, but DBA mountings
are no longer available.

For outdoor application of the
RDB, DBU and DBA fuses, it
is important that fuses that
have not operated are not left
hanging in the disconnected
position for extended periods.
If the weather seals on these
fuses are broken or damaged,
it is possible for water to
enter and damage the fuse
unit or fuse refill unit. The
integrity of these seals is
directly related to the
integrity of the fuse unit or
fuse refill unit. Seals should
be checked periodically and
an affected fuse unit or fuse
refill unit replaced. The
condition of the paint on the
fuse unit should also be
checked periodically.
Eaton expulsion fuses use
boric acid for the interrupting
medium. When the fuse
element melts, the heat of
the arc decomposes the boric
acid, releasing water vapor
that cools and extinguishes
the arc by blasting through it
and exiting the bottom of the
fuse. The interruption
process produces both a flow
of exhaust gas and a good
deal of noise. To moderate
the pressure wave and noise,
an exhaust control device is
added to indoor fuses.
Exhaust control devices limit
the exhaust to a small and
relatively inert amount of gas
while lowering the noise
level, but have little or no
effect on the interrupting
rating of the fuse. Mufflers
and condensers absorb and
contain the exhaust while
drastically reducing the noise
level; however, a condenser
or muffler may cause a
reduction of the interrupting
rating of the fuse.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-3

2.2
2

Expulsion Fuses
Fuse Selection

Contents

DBU Outdoor Mounting

Description

2

Page

Fuse Selection
Interrupting Rating . . . . . . . . . . . . . . . . . . . . . .
Continuous Current Rating . . . . . . . . . . . . . . . .
Coordination . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
2

V14-T2-5
V14-T2-7
V14-T2-9

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Fuse Selection
There are four factors
involved in the selection of a
boric acid expulsion fuse.
The first three considerations
are the rated maximum
voltage, the rated maximum
interrupting current including
the rate of rise of the
transient recovery voltage,
and the rated continuous
current of the fuse. Proper
attention must be given to
each of these as improper
application in any one of
these areas may result in the
fuse failing to perform its
intended function. The fourth
consideration is coordination
with line and load side
protective equipment that is
needed to give selectivity of
outage and to prevent
premature operation.
Each of these four areas is
discussed in detail.

Voltage Rating
The first consideration
regarding fuse application is
that the fuse selected must
have a rated maximum
voltage equal to or greater
than the maximum power
frequency voltage that could
be impressed across the fuse
under any possible
conditions. In most cases,
this means that the rated
maximum voltage of the fuse
must equal or exceed the
system maximum line-to-line
voltage. The only exception
to this rule occurs when
fusing single-phase loads
connected from line-toneutral on an effectively
grounded four-wire system.
Here, the fuse rated
maximum voltage need only
exceed the system maximum
line-to-neutral voltage,
providing it is impossible for
the fuse to experience the full

line-to-line voltage under any
fault condition. A good rule of
thumb is that if more than
one phase of the system is
extended beyond the fuse
location, the fuse rated
maximum voltage must equal
or exceed the system
maximum line-to-line voltage,
regardless of how the threephase system is grounded on
the source side of the fuse or
how the transformers or
loads are connected on the
load side of the fuse. It is a
fairly common practice to
fuse wye grounded wye
transformers with fuses that
have a rated maximum
voltage that only exceeds
then system line-to-neutral
voltage. In most cases, this
presents no problem, but the
user should be aware of the
remote possibility of a

2
2
2
2
2
2
2
V14-T2-4

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

secondary phase-to-phase
fault that could impose full
line-to-line voltage across a
single fuse. When only one
phase of a four-wire
effectively grounded system
is extended beyond the fuse
location to supply a load
connected from phase-toneutral, it is usually
acceptable to have the fuse
rated maximum voltage equal
or exceed the maximum lineto neutral voltage.
It is permissible for expulsion
fuse rated voltage to exceed
the system voltage by any
desired amount but under no
circumstances may the
system maximum voltage
exceed the fuse rated
maximum voltage.

2.2

Expulsion Fuses
Fuse Selection

Interrupting Rating

The rated maximum
interrupting current of a boric
acid expulsion fuse is the rms
value of the symmetrical AC
component of the highest
current that the fuse has been
demonstrated to be able to
interrupt under any conditions
of asymmetry with specified
circuit conditions. In other
words, the rated maximum
interrupting current denotes
the maximum symmetrical
fault current permitted at the
fuse location. Historically, boric
acid expulsion fuses have
alternately been rated in terms
of asymmetrical fault current.
Asymmetrical currents are
related to symmetrical
currents by the asymmetry
factor, which is the ratio of the
rms values of the
asymmetrical and symmetrical
currents. The asymmetrical
current includes the decaying
DC component of the fault
current. Asymmetry factors
are a function of the circuit X/R
ratio, and this relationship is
shown below. Theoretically,
the maximum asymmetry
factor in a purely inductive
circuit 1.732; however, with
X/R ratios encountered in
power circuits, it is rarely ever
more than 1.6. Fuse standards
suggest an asymmetry factor
of 1.56 to 1.6. The minimum

asymmetry factor at which
Eaton boric acid expulsion
fuses are tested to determine
their rated maximum
interrupting current is 1.6. In
general, historically stated
asymmetrical rms rated
maximum interrupting
currents can be converted to
their rms symmetrical rated
maximum counterparts by
dividing the asymmetrical
value by 1.6.
Historically, a third way to
state the interrupting rating of
a boric acid expulsion fuse
was with nominal three-phase
kVA ratings. Three-phase kVA
ratings are calculated by the
formula kVA = I x kV x 1.732,
where I is the rated maximum
interrupting current in
symmetrical rms amperes and
kV is the fuse nominal voltage
rating. With this method, it
must be kept in mind that
fuses are not constant kVA
devices, that is, if the voltage
is half the fuse rating, the
interrupting current does not
double but remains the same.
The fuse will interrupt any
current up to the rated
maximum interrupting current
as long as the power
frequency voltage does not
exceed the rated maximum
voltage of the fuse.
Interrupting ratings for each
type of Eaton expulsion fuse
are listed in the detailed
sections for each fuse type.

2

Asymmetry Factors

Asymmetry Factor at 1/2 Cycle

Under no circumstance should
a fuse be applied in a situation
where the available fault
current exceeds the
interrupting rating of the fuse.

1.7

2

1.6

2

1.5

2

1.4

2

1.3

2

1.2

2

1.1

2
1

2

3

4

5

10
20
Circuit X/R Ratio

2

30 40 50

2
When the fusible element in
an expulsion fuse melts as
the result of a fault, an arc is
established within the fuse.
Normal operation of an
expulsion fuse causes
elongation of the arc due to
spring tension. The current
continues to flow in the
circuit and within the fuse
until a natural current zero of
the circuit is reached. When
the arc is extinguished at a
current zero, the voltage
across the fuse terminals
changes abruptly from a
relatively low value of arc
voltage to the power
frequency recovery voltage.
The rapid voltage change, in
association with the inherent
capacitance in the circuit,
causes a short duration high
frequency voltage oscillation
to be superimposed on the
power frequency recovery

voltage. This combination of
power frequency voltage and
high frequency oscillatory
voltage is known as the
Transient recovery voltage.
Transient recovery voltages
produce high voltage
stresses across the fuse
terminals. The dielectric
strength between the fuse
terminals must rise faster
than the transient recovery
voltage if a successful
interruption is to occur. The
natural frequency of the
transient recovery voltage is
determined by the circuit
inductance and capacitance,
and the amplitude and decay
rate are determined by the
circuit resistance. The peak
factor is the ratio of the
highest (first) peak of the
transient recovery voltage to
the power frequency
recovery voltage.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-5

2.2
2
2
2
2
2
2
2
2
2

Expulsion Fuses
Fuse Selection

Primary faults, or faults on
the primary side of a
transformer, will generally
produce higher short-circuit
currents and less severe
transient recovery voltages.
Secondary faults produce
lower fault currents and more
severe transient recovery
voltages. This is due to the
insertion of the transformer
impedance in the circuit.
Eaton recognizes the effects
of the different parameters
involved in primary and
secondary fault phenomena.
These various conditions are

also reflected in the test
parameters called for in IEEE
Std. C37.41-2000™. Eaton’s
line of expulsion fuses have
proven their ability to
successfully withstand the
transient recovery voltage
associated with both types
of faults. The table on Page
V14-T2-6 lists the frequency
of the transient recovery
voltage and amplitude factors
at which these fuses were
tested. These conditions
meet or exceed the
requirements of the ANSI
Standards.

Another consideration when
applying power fuses is the
altitude at which they are
installed. The dielectric
strength of air decreases with
increasing altitude. De-rating
is required for applications at
altitudes above 1000 meters
(3300 feet). Correction factors
for various altitudes are listed
in IEEE Std. C37.40™.
Fuses are fault protective
devices, and are overload
tolerant not overload
protective devices. By
design, power type expulsion

fuses are not intended to
operate on fault currents
below the secondary terminal
fault of the associated
transformer. Distribution type
expulsion fuses can be used
where the protection
requirements call for a
greater degree of overload
protection. However, E-rated
and K-rated fuses do not
provide protection for fault
currents less than two times
the continuous current rating
of the fuse.

Transient Recovery Voltage Values for RBA, RDB and DBU Fuses

Nominal

Maximum Design

Transient Recovery Voltage Values
Primary Fault Recovery
Frequency in kHz
Amplitude Factor

2.40

2.75

9.0

1.6

26.0

1.6

2

4.16

4.80

9.0

1.6

26.0

1.6

4.80

5.50

9.0

1.6

26.0

1.6

2

7.20

8.25

9.0

1.6

26.0

1.6

13.80

14.40

5.5

1.6

17.4

1.6

14.40

15.50

5.5

1.6

17.4

1.6

23.00

25.50

4.2

1.6

13.0

1.6

34.50

38.00

3.9

1.6

8.5

1.6

2
2

2
2

Voltage kV

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V14-T2-6

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Secondary Fault Recovery
Frequency in kHz

Amplitude Factor

2.2

Expulsion Fuses
Fuse Selection

Continuous Current Rating
Eaton’s expulsion fuses are
designed to carry rated
current continuously
without exceeding the
temperature and temperature
rise limits permitted by
IEEE Std. C37.40™-2003
when tested as specified in
IEEE Std. C37.41™-2000. The
ranges of continuous current
ratings available in Eaton’s
fuses are shown in the table
below. These current ratings
carry either an E or a K
designation as defined in
ANSI C37.42-1996 or
ANSI C37.46-2000.
The current responsive
element of a power fuse with
a continuous current rating of
100E or below shall melt in
300 seconds at an rms
current between 200% and
240% of the continuous
current rating.
The current responsive
element of a power fuse with
a continuous current rating of
above 100E shall melt in 600
seconds at an rms current
between 220% and 264% of
the continuous current rating.

The current responsive
element of a distribution fuse
with a K designation on the
current rating shall melt
within the required time
ranges specified for various
current levels in Table 8 of
ANSI C37.42-1996.
Although the E and K ratings
do not make time current
curves identical, they do
produce a similarity among
different manufacturer’s
fuses, as they all must satisfy
the same requirements. The
E and K ratings also reflect
the 2:1 minimum melting
current versus continuous
current rating that is a design
feature of these fuses.
Note that this similarity
between the time current
curves of E-rated expulsion
fuses from various
manufacturers does not imply
that the time current curves
of E-rated expulsion and
current limiting fuses are
similar even from the same
manufacturer—there are in
fact, considerable differences,
and this must be considered
when comparing expulsion
and current-limiting fuses.

Power fuses are designed to
continuously carry their rated
current without exceeding
temperature rise restrictions.
If rated current is exceeded
enough to cause the
temperature or temperature
rise limits to be exceeded,
but the current is still below
the 300 or 600 second
melting current for a
considerable length of time, a
large amount of heat will be
generated that may cause
permanent damage to the
fuse. Even though the DBU
and RBA/RDB standard fuses
employ silver elements that
are not subject to thermal
degradation unless the
element temperature nearly
reaches the melting
temperature, caution should
still be exercised when
overloading the fuse as
prolonged overheating will
cause deterioration of the
boric acid interrupting
medium and charring of the
fuse wall before the fuse
element melts. The following
curve shows the overload
characteristics of Eaton’s
expulsion fuses. Do not
exceed these overload
restrictions under any
circumstances.

In practice, expulsion power
fuses are used to protect
transformers and other
equipment where overloads
and inrush currents are
common. As boric acid
expulsion fuses have a rather
low thermal capacity and
cannot carry overloads of the
same magnitude and duration
as motors and transformers
of equal continuous currents,
general fuse application ratio
of 1.4:1 fuse continuous
current rating to full load
current is suggested to
prevent nuisance fuse
operations on acceptable
overloads and inrush
conditions. Remember that
this is only a general ratio for
typical applications, and that
ratios as low as 1:1 or as high
as 2:1 can be used for
specific applications. More
specific application
information can be found in
the individual equipment
applications sections that
follow.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Continuous Current Ratings Available in Eaton Expulsion Fuses

2

Maximum
Design kV

RBA-RDB-200
Standard

RBT-200
Time Lag

RBA-RDB-400
Standard 

RBT-400
Time Lag

DBU Standard

DBU Slow

DBU K-Rated

DBA-1, 2
Standard

2.75

10E to 200E

20E to 200E

0.5E to 400E1

20E to 400E1

—

—

—

—

5.50

10E to 200E

20E to 200E

0.5E to 400E1

20E to 400E1

—

—

—

—

8.25

10E to 200E

20E to 200E

0.5E to 400E1

20E to 400E1

—

—

—

0.5E to 200E

14.40

10E to 200E

20E to 200E

0.5E to 400E1

20E to 400E1

5E to 200E

15E to 200E

3K to 200L

0.5E to 200E

15.50

10E to 200E

20E to 200E

0.5E to 400E1

20E to 400E1

5E to 200E

15E to 200E

3K to 200L

0.5E to 200E

25.50

10E to 200E

20E to 200E

0.5E to 300E2

20E to 300E2

5E to 200E

15E to 200E

3K to 200L

0.5E to 200E

38.00

10E to 200E

20E to 200E

0.5E to 300E2

20E to 300E2

5E to 200E

15E to 200E

3K to 200L

0.5E to 200E

2

Note
Using the two paralleled 800 fuse design, which has a 10% derating factor, ratings of 450, 540 and 720 are available.



2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-T2-7

2.2
2
2
2

Hrs.
6
4
3

2

2

1

2
2
2
2

Above
100A
1/2
100A
or Less
Sec.
1000
600

2
2

Fuse Selection

Overload Characteristics
for Eaton Expulsion Fuses

2
2

Expulsion Fuses

Eaton’s expulsion type
fuses must not be
paralleled to obtain
continuous current ratings
greater than those
indicated, with the
exceptions stated below.
Satisfactory operation of
untested parallel
arrangements cannot be
predicted.

Corrections for applying
expulsion fuses above
3300 feet also apply to the
continuous current ratings as
well as the interrupting rating.
De-rating is required for
applications at altitudes
above 1000 meters (3300
feet). Correction factors for
various altitudes are listed in
IEEE Std. C47.40™.

RBA-8, RDB-8 and BA-8
assemblies have been
specifically tested to
demonstrate their correct
operation throughout the
rated range of interrupting
currents, with the specific
physical arrangements
shown.

Remember that:
●

●

Under no circumstances
must the continuous rating
of the fuse be less than the
continuous load current
E-rated fuses do not
provide protection for
currents below two times
the continuous current
rating

Average
Melting
Curves
300

2
100

2
2

1

2
3
100% of Fuse Rating

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V14-T2-8

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
Fuse Selection

2.2

Coordination
In addition to selecting a fuse
that meets the voltage,
interrupting and continuous
current ratings, it is important
to examine the time-current
curves of the fuse. These
curves are designated as
minimum melt and total
clearing curves. The
minimum melt curve gives
the minimum amount of time
in seconds required to melt
the fuse elements at a
particular value of rms
symmetrical current under
specified conditions. The total
clearing curve gives the
maximum amount of time in
seconds to complete
interruption of the circuit
at a particular value of rms
symmetrical current under
conditions specified in
ANSI C37.42-1996 or
ANSI C36.46-2000.
The time-current curves for
Eaton fuses are derived
from tests on fuses at an
ambient temperature of
25 degrees C and no initial
loading as specified in
IEEE Std. C37.46™.

Arcing time is defined as the
amount of time in seconds
elapsing from the melting of
the fusible element to the
final interruption of the
circuit. It is important to
examine these characteristics
to assure proper protection
and selectivity with other
overcurrent protective
devices. These curves are
located in each fuse section
of the catalog.
The melting curves of all
E-rated fuses must lie within
the range defined in IEEE Std.
C37.46™ at either the 300 or
600 second point, but there
are no limitations placed on
the melting time at high
currents. To take advantage
of this, Eaton increases the
applicability of their fuses by
producing fast or standard
fuses and slow or time-lag
fuses. The curves for time-lag
fuses are less inverse and
allow for more of a time delay
at high currents.
The melting curves of all Krated DBU fuses must lie
within the ranges defined in
IEEE Std. C37.42™.

Proper coordination of power
fuses requires keeping the
minimum melting current
time-current curve above the
total clearing time-current
curve of any downstream
protective device, and
keeping the total clearing
time-current curve beneath
the minimum melting timecurrent curve of any
upstream protective device.
Manufacturers publish timecurrent curves based on
standard conditions that do
not allow for variables such
as pre-loading or ambient
temperature. Fuses subject
to conditions other than the
above will experience shifts
in the time-current curves.
For this reason, it is
recommended that a safety
zone be used to ensure that
proper coordination is
maintained allowing for these
variables. Eaton recommends
the use of a 10% safety zone
on current for a particular
value of time as it allows the
safety band to be published
on the left-hand side of all the
time-current curves.
Coordination is then achieved
by overlaying curves and
shifting one by the width of
the published safety zone.

Although the relevant ANSI
and IEEE standards allow a
20% tolerance band on
current between minimum
and maximum melting
characteristics, Eaton
published characteristics in
general only show a 10%
tolerance band that can be
seen for times greater than
0.5 second. Note that the
published upper limit timecurrent curve is for total
clearing, and not maximum
melting. The total clearing
time-current curve gives the
maximum melting time plus
the arcing time of the fuse.
If desired or if unusual
conditions exist, shifts in the
time-current curve due to preloading may be examined
individually. The following
illustration gives the adjusting
factor for preloaded fuses.
These adjusting factors are
valid only for Eaton power
fuses.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Preloading Adjustment Factor for Eaton Expulsion Fuses

2

Melting Time in Percent
of Time Shown on TimeCurrent Characterist Curve

F

2
2

100
Fuses Above 100A

2

Fuses 100A and Less
50

2
2

0

0

50
100
150
200
Load Current in Percent of Fuse Ampere Rating

250 P

2
2
2
2
2
2
Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-T2-9

2.3
2

Expulsion Fuses
Application

Contents

RBA Fuses

Description

2

Page

Application
Transformer Application . . . . . . . . . . . . . . . . . .
Repetitive Faults . . . . . . . . . . . . . . . . . . . . . . . .
Repetitive Faults . . . . . . . . . . . . . . . . . . . . . . . .

2
2

V14-T2-12
V14-T2-19
V14-T2-19

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Application
Use of the current generation
of protection and coordination
computer programs has
taken much of the hard work
out of checking coordination
between medium voltage
fuses and the upstream and
downstream devices and
protective equipment in the
circuit. In addition, they allow
detailed analysis of potential
arc flash that could occur due
to faults at particular circuit
locations. Additional
considerations such as the
effects of cable run lengths
can also be included in the
fault current calculations to
increase the accuracy of
coordination and arc flash
studies. However, a basic
understanding of the
coordination principles behind
such studies is necessary for
correct interpretation of the
results.

When applying expulsion
fuses, physical as well as
electrical properties must be
considered. Expulsion fuses
emit gases from the bottom
of the fuse and as a result,
care should also be taken to
maintain minimum phase-tophase and phase-to-ground
clearances when mounting
fuses. Indoor fuses employ
an exhaust control device, a
discharge filter, a muffler or a
condenser to absorb some or
most of the exhaust from the
fuse but specified clearances
must still be maintained.

Outdoor fuses are vented and
thus have a high noise level
and expel a greater amount of
gas making clearance from
ground an important
consideration. However, the
noise level of outdoor power
fuses that employ boric acid
solid material to control the
arcing process is generally
much lower, and the exhaust
column is less violent than
that associated with fuses
employing links and cutouts,
even at higher levels of
interrupting current. When
applying outdoor fuses,
clearance must also be
allowed for the arc that the
fuse swings through during
dropout. The tables on Page
V14-T2-11 give the minimum
clearance to ground and the
minimum phase spacing.

2
2
2
2
2
2
2
V14-T2-10

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Outdoor fuses are vented,
and the venting of the hot
gases resembles a cylindrical
or narrowly conical column
height above the minimum
ground clearance. It is not
really a factor except as
related to rebounding from
the ground of hot particles
and gases. The illustration on
Page V14-T2-3 shows the
nature of the discharge and
allows the user to suggest
specific safety zones for each
particular application.

Expulsion Fuses
Application

2.3

Recommended Spacings—Typical Single Fuse Unit
Typical Filter or Condenser

2

Typical Vented

2

Typical paralleled fuse unit
with standard Eaton
mounting.

A

A

2

Legend

2

A = Recommended phase-to-phase
centerline spacing without barriers
B = Minimum clearance to ground

400

400

800

B

2
2

800

B

2
2
2

(A) Recommended Phase-to-Phase Centerline Spacing without Barriers in Inches
Maximum
Design kV

RBA Disconnect
200/400
800

RBA Non-Disconnect
200/400
800

RDB
200/400

800

DBU

DBA

2.75

11.75

27.51

11.16

19.92

19.0

26.76

17.0

17.0

4.80

11.75

27.51

11.16

19.92

18.0

26.75

17.0

17.0

5.50

11.75

27.51

11.16

19.92

18.0

26.75

17.0

17.0

8.25

13.25

29.01

12.56

21.32

18.0

26.76

17.0

17.0

14.40

14.75

30.51

13.06

21.82

24.0

32.76

19.0

19.0

15.50

16.25

32.01

15.56

24.32

24.0

32.76

19.0

19.0

25.50

20.25

—

19.56

—

30.0

38.76

23.0

23.0

38.00

25.25

—

24.56

—

36.0

44.76

30.0

30.0

48.30

—

—

—

—

—

—

—

33.0

72.50

—

—

—

—

—

—

—

44.0

2
2
2
2
2
2
2
2

(B) Minimum Clearance to Ground in Inches
Maximum Design kV

RBA Filter

RBA Condenser

RDB-200, DBU and
DBA-1 Vented

RDB-400, 800 and
DBA-2 Vented

2

2.75

7.5

3.0

17.5

22.0

2

4.80

7.5

3.0

17.5

22.0

5.50

8.5

4.0

17.5

22.0

8.25

8.5

4.0

17.5

22.0

14.40

11.5

6.0

21.0

26.0

15.40

11.5

6.0

21.0

26.0

25.50

15.0

8.5

26.0

32.0

38.00

19.5

12.0

33.0

42.0

48.30 (DBA only)

—

—

40.0

54.0

72.50 (DBA only)

—

—

54.0

84.0

2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-11

2.3

Transformer Application

2
2
2

●

2
2
2
2

●

2
2
2
2
2
2
2
2
2
2
2
2
2

●

Selecting the proper voltage,
interrupting and continuous
current ratings for the fuse is
straightforward and has been
sufficiently covered in their
respective sections.

Fuses on the primary side of
transformers should not
operate on transformer
magnetizing or inrush current.
The magnitude of the first loop
of inrush current and the rate at
which the peaks of subsequent
loops decay is a function of
many factors. Some of these
are transformer design, residual
flux in the core at the instant of
energization, the point on the
voltage wave at which the
transformer is energized and
the characteristics of the source
supplying the transformer.
When energizing, the heating
effect of the inrush current can
be considered equal to 12 times
the transformer full load current
for 1/10 of a second. Thus,
when selecting the current
rating for fuses used at the
primary side of a transformer,
the fuse minimum melting
curve must lie above and to the
right of the point on the timecurrent curve representing 12
times full load current and 0.1
seconds. The fuse whose
minimum melting curve lies just
above and to the right of this
point is the lowest rated fuse
that can be used at the primary
terminals to satisfy the inrush
requirements. This criterion is
normally satisfied for all Eaton
expulsion fuses if the fuse
current rating is equal to or
greater than the transformer
self-cooled full load current.
Thus, a fusing ratio as low as
1:1 could be used in selecting
primary side fuses if inrush or
magnetizing current were the
only concern.

200

100
80
60
40
20

10
8
6
4
2

1
0.8
0.6
0.4
0.2

0.1
0.08
0.06
0.04
0.02

0.01

Scale x 10 = Secondary Current In Amperes
4.8 kV

A

RBA
200E

C

B

480V
DS-416
1200 LSI

C

C

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Breaker

LD
LD SD
Amps PU T

SD I
PU T

BDS-416

1200

CCDS-206 400

1000 kVA

2
V14-T2-12

Total
Clearing

DS-206
400 LI

8000
10000

2

Minimum
Melt

6000

2

A

4000

2

400

B

2000

2

C

800
1000

2

600

600

2

1000
800

400

2

Protect the system on the
source side of the fuses from
an outage due to faults in or
beyond the transformer
(isolate a faulted transformer
from an otherwise healthy
distribution system to
prevent further
disturbance)—in the case of
an internal winding fault in
the transformer, the fuse
should prevent further
collateral damage to the
transformer and its
surroundings (although the
primary fuses will isolate a
transformer with an internal
fault from the primary
system, expulsion fuses
generally are not fast enough
to prevent extensive damage
to the transformer)
Coordinate with protection
on the low-voltage side of
the transformer (transformer
primary protection must be
overload tolerant, allowing
the secondary protection to
clear faults occurring
downstream of the
secondary protection)
Protect the transformer
against bolted secondary
faults (the fuse should
operate on any bolted
secondary faults, between
the transformer secondary
terminals and the secondary
protection before the
transformer is damaged—
usually thru-fault protection is
provided to the transformer
by a main secondary breaker
or breakers and the main
purpose of the primary fuses
is to isolate a faulted
transformer from the primary
system)
Protect the transformer
against higher impedance
secondary faults to whatever
extent is possible (the fuse
should limit damage to the
transformer windings to the
best extent possible)

Typical Fuse—Transformer Coordination

200

●

There are two sometimes
conflicting factors when
selecting a fuse to protect a
transformer circuit. The
continuous current rating must
be large enough to prevent
premature fuse interruption
from magnetizing or inrush
currents and it must also be
large enough to prevent fuse
deterioration or fuse
interruption during normal or
emergency overload situations.
The fuse rating must also be
small enough to provide the
protection listed in the purpose
hierarchy.

60
80
100

Fuses are installed on the
primary side of a transformer to:

40

2

Application

Time In Seconds

2

Expulsion Fuses

PU

IX

4
sec

4X

0.18 12X
sec

IX

20
sec

—

—

9X

Expulsion Fuses
Application

System operators frequently
overload their transformers
for short periods of time
during normal and emergency
situations. To allow this
flexibility, it is necessary to
select a fuse that can carry
the overload without
deteriorating. To accommodate
these overloads, a fusing
ratio higher than 1:1 is almost
always required when
applying fuses for transformer
protection. The fuse
emergency overload curve on
Page V14-T2-8 along with
the required extent of
overloading is used to
determine the smallest fuse
that can be applied. Determine
the minimum fuse rating by
using the duration (ordinate)
of the transformer overload
on the fuse overload curve on
Page V14-T2-8 to obtain the
multiple of the current rating
that should not be exceeded.

Divide the transformer
overload current by the
multiple obtained from the
overload curve. The result is
the minimum fuse current
rating. Select the fuse rating
that equals or is just larger
than this value. The allowable
time duration of the current in
the primary side fuses during
transformer overload should
never exceed the values
shown by the fuse overload
curve on Page V14-T2-8.
Note: Short term and long term
overloading of transformers will
adversely affect the service life of
the transformer. Also, increasing
the primary fuse size to allow for
higher overloads decreases the
protection afforded the transformer.
The extent to that transformers
are overloaded and the
implications for system security
are economic decisions that are
made by the system operator.

2.3

Suggested minimum fuse
sizes for protection of selfcooled transformers are given
in the tables on Pages
V14-T2-14 and V14-T2-15.
These tables are based on
the premise that the maximum
1.5 hour overload on the
transformer would not exceed
200 percent of the transformer
rating. This overload condition
requires that the minimum
ratio of fuse current rating to
transformer full load current
is 1.4:1. Fuse sizes listed
in the tables on Pages
V14-T2-14 and V14-T2-15
are those that are just
higher than 1.4 times the
transformer full load current.
If higher or longer duration
transformer overloads are to
be permitted, a fuse with a
higher continuous current
rating may be required. The
procedure described above
should then be used to find
the smallest permissible
fuse size.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-13

2.3
2
2
2
2
2

Expulsion Fuses
Application

Suggested Minimum Expulsion Fuse Current Ratings
Self-Cooled 2.4 to 12.0 kV Power Transformer Applications
Nominal kV
Fuse Maximum kV
Transformer Full kVA
Rating Self-Cooled

2.4
8.3
Full Load
Current
Amps

2.4
8.3
Fuse
E-Ampere
Rating

4.16
8.3
Full Load
Current
Amps

4.16
8.3
Fuse
E-Ampere
Rating

4.8
8.3
Full Load
Current
Amps

4.8
8.3
Fuse
E-Ampere
Rating

7.2
8.3
Full Load
Current
Amps

7.2
8.3
Fuse
E-Ampere
Rating

12.0
15.5
Full Load
Current
Amps

12.0
15.5
Fuse
E-Ampere
Rating

Three-Phase Transformers
9

2.16

3E

1.25

3E

1.10

3E

0.72

3E

0.43

3E

2

15

3.60

5E

2.08

3E

1.80

3E

1.20

3E

0.72

3E

30

7.20

10E

4.20

7E

3.60

5E

2.40

5E

1.44

3E

2

45

10.80

15E

6.20

10E

5.40

10E

3.60

5E

2.16

3E

75

18.00

25E

10.40

15E

9.00

15E

6.00

10E

3.60

5E

112

27.00

40E

15.60

25E

13.60

20E

9.00

15E

5.40

10E

150

36.00

50E

20.80

30E

18.00

25E

12.00

20E

7.20

10E

225

54.00

80E

31.30

50E

27.20

40E

18.00

25E

10.80

15E

2

300

72.00

100E

41.60

65E

36.00

50E

24.00

40E

14.40

20E

500

120.00

200E

69.40

100E

60.00

100E

40.00

65E

24.10

40E

2

750

180.00

250E

104.00

150E

90.00

125E

60.00

100E

36.10

50E

1000

241.00

400E

2
2

2

140.00

200E

120.00

200E

80.00

125E

48.10

80E



100E

1500

360.00

540E

208.00

300E

180.00

250E

120.00

200E

72.00

2000

481.00

720E 

278.00

400E

241.00

400E

160.00

250E

496.20

150E

2500

600.00

—

346.00

540E 

301.00

450E 

200.00

300E

120.00

200E

2

3750

—

—

—

—

—

…

—

—

180.00

250E

5000

—

—

—

—

—

…

—

—

241.00

400E

2

Single-Phase Transformers

2

5

2.08

3E

1.20

3E

1.04

3E

0.69

3E

0.416

3E

10

4.17

7E

2.40

5E

2.08

3E

1.39

3E

0.832

3E

2

15

6.25

10E

3.60

5E

3.13

5E

2.08

3E

1.25

3E

25

10.40

15E

6.00

10E

5.20

10E

3.47

5E

2.08

3E

2

37

15.60

25E

9.00

15E

7.80

15E

5.21

10E

3.12

5E

50

20.80

30E

12.00

20E

10.40

15E

6.95

10E

4.16

7E

75

31.30

50E

18.00

25E

15.60

25E

10.40

15E

6.25

10E

100

41.70

65E

24.00

40E

20.80

30E

13.90

20E

8.32

15E

167

70.00

100E

40.00

65E

35.00

65E

23.20

40E

13.90

20E

2

250

104.00

150E

60.00

100E

52.00

80E

34.80

50E

20.80

30E

333

139.00

200E

80.00

125E

69.50

100E

46.30

65E

27.70

40E

2

500

208.00

300E

120.00

200E

104.00

150E

69.60

100E

41.60

65E

667

278.00

400E

160.00

250E

139.00

200E

92.60

150E

55.40

80E

833

347.00

540E 

200.00

300E

173.00

250E

115.50

200E

69.40

100E

1250

521.00

720E 

300.00

540E 

260.00

400E

174.00

250E

104.00

150E

2

2
2

2
2
2
2

Notes
Two (2) 300E ampere fuse refills used in parallel with 10% derating factor.
 Two (2) 400E ampere fuse refills used in parallel with 10% derating factor.
 Two (2) 250E ampere fuse refills used in parallel with 10% derating factor.


2
2
2
2
V14-T2-14

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

2.3

Expulsion Fuses
Application

Self-Cooled 13.2 to 34.5 kV Power Transformer Applications
System
Nominal kV
Fuse
Maximum kV
Transformer
Full kVA
Rating
Self-Cooled

2

13.2

13.2

13.8

13.8

14.4

14.4

22.9

22.9

23.9

23.9

24.9

24.9

34.5

34.5

15.5

15.5

15.5

15.5

15.5

15.5

25.5

25.5

25.5

25.5

25.5

25.5

38.0

38.0

Full Load Fuse
Full Load Fuse
Full Load Fuse
Full Load Fuse
Full Load Fuse
Full Load Fuse
Full Load Fuse
Current
E-Ampere Current
E-Ampere Current
E-Ampere Current
E-Ampere Current
E-Ampere Current
E-Ampere Current
E-Ampere
Amps
Rating
Amps
Rating
Amps
Rating
Amps
Rating
Amps
Rating
Amps
Rating
Amps
Rating

Three-Phase Transformers
9.00

0.40

3E

0.38

3E

0.36

1/2E

0.22

1/2E

0.21

1/2E

0.20

1/2E

0.15

1/2E

15.00

0.66

3E

0.62

3E

0.60

3E

0.38

3E

0.36

1/2E

0.35

1/2E

0.25

1/2E

30.00

1.32

3E

1.25

3E

1.20

3E

0.75

3E

0.72

3E

0.69

3E

0.50

3E

45.00

1.98

3E

1.88

3E

1.80

3E

1.14

3E

1.09

3E

1.04

3E

0.75

3E

75.00

3.30

5E

3.10

5E

3.00

5E

1.89

3E

1.81

3E

1.74

3E

1.25

3E

112.50

4.95

7E

4.70

7E

4.51

7E

2.84

5E

2.72

5E

2.60

5E

1.88

3E

150.00

6.56

10E

6.20

10E

6.01

10E

3.78

7E

3.62

5E

3.47

5E

2.51

5E

225.00

9.90

15E

9.40

15E

9.02

15E

5.68

10E

5.44

10E

5.21

10E

3.77

7E

300.00

13.10

20E

12.50

20E

12.00

20E

7.58

15E

7.25

10E

6.94

10E

5.02

7E

500.00

21.90

30E

21.00

30E

20.10

30E

12.60

20E

12.10

20E

11.60

20E

8.37

15E

750.00

32.80

50E

31.00

50E

30.10

50E

18.90

30E

18.10

25E

17.40

25E

12.60

20E

1000.00

43.70

65E

42.00

65E

40.10

65E

25.30

40E

24.20

40E

23.10

40E

16.70

25E

1500.00

65.60

100E

62.00

100E

60.10

65E

37.90

65E

36.20

50E

34.70

50E

25.10

40E

2000.00

87.50

125E

84.00

125E

80.20

125E

50.50

80E

48.30

80E

46.30

65E

33.50

50E

2500.00

109.00

150E

104.00

150E

100.00

150E

63.10

100E

60.40

100E

57.90

80E

41.80

65E

3750.00

165.00

250E

156.00

250E

150.00

250E

94.70

150E

90.60

150E

86.60

125E

62.80

100E

5000.00

218.00

300E

210.00

300E

200.00

300E

126.00

200E

121.00

200E

116.00

200E

83.70

125E

Single-Phase Transformers
5.00

0.38

3E

0.36

3E

0.35

1/2E

0.22

1/2E

0.21

1/2E

0.20

1/2E

0.14

1/2E

10.00

0.76

3E

0.72

3E

0.69

3E

0.44

3E

0.42

3E

0.40

3E

0.29

1/2E

15.00

1.14

3E

1.09

3E

1.64

3E

0.66

3E

0.63

3E

0.60

3E

0.43

3E

25.00

1.90

3E

1.81

3E

1.74

3E

1.09

3E

1.05

3E

1.00

3E

0.72

3E

37.50

2.84

5E

2.71

5E

2.60

5E

1.64

3E

1.57

3E

1.50

3E

1.09

3E

50.00

3.80

7E

3.62

5E

3.47

5E

2.19

3E

2.09

3E

2.00

3E

1.45

3E

75.00

5.70

10E

5.43

10E

5.21

10E

3.28

5E

3.14

5E

3.01

5E

2.17

3E

100.00

7.60

15E

7.24

10E

6.94

10E

4.37

7E

4.18

7E

4.01

7E

2.90

5E

167.00

12.70

20E

12.10

20E

11.60

20E

7.31

10E

6.99

10E

6.70

10E

4.84

7E

250.00

19.00

30E

18.10

25E

17.40

25E

10.90

15E

10.50

15E

10.00

15E

7.25

10E

333.00

27.70

40E

25.20

40E

23.10

40E

14.60

20E

13.90

20E

13.40

20E

9.65

15E

500.00

38.00

65E

36.20

50E

34.70

50E

21.90

30E

20.90

30E

20.10

30E

14.50

20E

667.00

50.50

80E

48.20

80E

46.30

65E

29.20

40E

27.90

40E

26.80

40E

19.30

30E

833.00

63.50

100E

60.40

100E

57.90

80E

36.40

50E

34.90

50E

33.40

50E

24.10

40E

1250.00

95.00

150E

90.60

125E

86.80

125E

54.70

80E

52.30

80E

50.10

80E

36.20

50E

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-T2-15

2.3
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Expulsion Fuses
Application

If provisions are made to limit
transformer overloads to a
lower range, by thermal or
other protective devices, the
ratio of fuse current to
transformer full load current
can be less than 1.4:1. To find
the amount of reduction
permissible without damage
to the fuse, the procedure
using the overload curve
should be employed.
When the transformer has
forced cooling, the minimum
fuse size that can be applied
should be based on the
transformer top rating and
the extent to which the
transformer will be overloaded
beyond the top rating.
It should be remembered that
E- or K-rated expulsion fuses
applied at the primary
terminals of a transformer do
not provide protection for
currents below two times the
continuous current rating of
the fuse. That is, for currents
that exceed the time limits
shown by the fuse overload
curve on Page V14-T2-5, the
fuse may have deteriorated
before the fusible element
melts. In order to provide
dependable overload
protection for the
transformer, protection must
be applied on the secondary
side of the transformer.

2
2
2
2

Equal concern should be
given to the upper limit of
continuous current rating that
will provide protection for the
transformer. The extent to
which the fuses are to
protect the transformer
against secondary faults is
one of several factors that
determines the upper limit.
When a main secondary
breaker is not used, the
primary fuses may be the
only devices that provide
thru-fault protection for the
transformer. In these
circumstances the fuse
should operate before the
transformer windings are
damaged due to heavy
currents. The capability of
transformer windings to carry
these thru-fault or heavy
currents varies from one
transformer design to
another. When specific
information applicable to
individual transformers is not
available, the transformer
heat curves shown on
Page V14-T2-18 can be used
to evaluate the thru-fault
protection offered the
transformer by the fuses. The
curve labeled N=1 is drawn
through the points defined in
IEEE Std. C57.92™, such that
the curve has the same
shape as shown in Figure 1 of
IEEE publication 273 titled,
“Guide to Protective Relay
Application to Power
Transformers”. This curve
applies to single-phase
transformers and to threephase faults on three-phase

transformer banks. Curves for
values of N other than 1 apply
to unsymmetrical faults on
three-phase transformers and
three-phase transformer
banks that have at least one
delta connected winding.
Ideally, the total clearing
time-current of the primary
fuse would lie below the heat
curve for all values of current
up to 25 times the
transformer rated current.
However this is not usually
possible as the fuse has
minimum limitations placed
on the rating due to long time
overload impressed on the
transformer and the fact that E-rated expulsion fuses do
not provide protection for
currents below two times
their continuous current
rating. In spite of these lower
limitations, primary side fuses
should protect the
transformer for bolted
secondary faults and higher
impedance secondary faults
to whatever extent is
possible.
Wye connected transformers,
regardless of whether or not
the neutral is grounded, tied
to the system neutral or
floating have line currents
that are equal to the winding
currents for faults external to
the transformer. Thus a fuse
connected to the terminal of
a wye connected winding will
see the same current that is
in the winding for all faults
external to the transformer.
Also, there is a simple
relation between the primary
and secondary amperes,
whether or not load of fault
currents are being
considered.

2
2
2
2
2
2
2
2
V14-T2-16

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

This is not the case when the
transformer has a delta
connected winding, either on
the primary or the secondary
side of the transformer. With
delta connected primary
windings the current in the
lines (fuses) supplying the
delta winding and currents in
the primary delta windings
generally are not equal, and
of greater importance, the
ratio of line (fuse) current to
the winding current varies
with the type of fault on the
external system. With delta
connected secondary
windings, the current in the
transformer secondary
windings is generally not
equal to the secondary line
current, and the ratio of
primary line current to the
secondary line current varies
with the type of fault on the
secondary system.

Expulsion Fuses
Application

The relationship between
rated line (fuse) current and
rated winding current
(referred to as the base
current of the winding in
IEEE/ANSI Std. C57.12.00™)
is 1 for wye connected
primaries and is 1/ 3 for delta
connected primaries. IEEE/
ANSI Std. C57.12.00™ also
indicates that the transformer
winding shall be capable of
withstanding 25 times rated
winding current for two
seconds and smaller
multiples of rated winding
current for longer periods of
time. However, transformer
overloads and faults are
generally expressed in terms
of line and not winding
current. This could present a
problem for fault conditions
where the type of fault
changes the relationship
between the line and the
winding current. The table
below gives a multiplier that
will translate the line current
in multiples of the winding
current for different type
faults for various transformer
windings. These tables lead
us back to the transformer
heat curves shown where it
can be verified that the curve
N=1 passes through the point
25 times full load line current
at two seconds. The curves
for other than N=1 are for
unsymmetrical faults as can be
seen from the table below.

Coordination diagrams
employ the transformer heat
curves and fuse time current
curves to determine which
fuse rating may be safely
applied. These diagrams are
the tools used to apply the
information previously cited.
The most straightforward
diagram involves fuses
applied at the terminals of
transformers with wye
primary windings. The table
below shows that the fuse
current is the same as the
winding current for all faults
external to the transformer.
This means the coordination
diagram consists simply of
the direct reading of the fuse
time-current curves and the
transformer heat curve N=1
for coordination diagrams
where the abscissa is labeled
in amperes in the primary
system. To coordinate with
the abscissa labeled in
secondary amperes, the
same two curves are shifted
to allow for the ratio between
the primary and secondary
amperes.

When fuses are employed at
the terminals of a delta-wye
transformer, the coordination
diagram becomes a bit more
involved. In this instance, the
table below shows that the
fuse current varies in relation
to the winding current
depending on the nature of
the fault. Thus, when the
coordination is with respect
to primary amperes, the
diagram consists of one
direct reading fuse timecurrent curve and one or
more transformer heat
curves. The number of heat
curves included would be
determined by the types of
secondary faults considered.
The table below gives the N
curve to be used for the
different faults to be
considered. When the
coordination is with respect
to secondary amperes the
diagram consists of one
transformer heating curve
(N=1) and up to three fuse
time-current curves. The
three time-current curves are
again dependent on the
possible faults to be
considered. The table below
shows that to obtain proper
coordination after the curve is
translated to secondary
amperes, it must be shifted
1/ 3 when phase-to-ground
faults are considered and
2/ 3 when phase-to-phase
faults are considered.

2.3

Regardless of whether a
primary or secondary current
abscissa is employed, a
coordination diagram for a
delta-wye transformer shows
that the primary side fuses do
not protect the transformer
for high impedance
secondary faults and
overloads. This type of
protection can be obtained
through the application of
secondary side breakers. If a
secondary breaker were
used, it would be added to
the coordination diagram by
plotting the breaker phase
and ground trip
characteristics. Selective
coordination would exist if
the breaker phase trip
characteristic curve lies
below the fuse characteristic
for a phase-to-phase fault
and the heating curve,
and breaker ground trip
characteristic for a single lineto-ground fault and the heat
curve.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Multiples of Primary Line Current for Fixed Secondary Winding Current

2

Transformer Connection
All Neutrals Grounded

N
(N Times Secondary Winding Current Gives Multiples of Primary Line Current)

Primary

Secondary

Three-Phase Fault

Phase-to-Ground Fault

Phase-to-Phase Fault

Y

Y

1

1

1

Y

D

1

—

1

D

Y

1

1/ 3

2/ 3

D

D

1

—

2
2
2
2

3/2

2
2
2
2
2
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-17

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Expulsion Fuses
Application

The preceding pertains to
diagrams using secondary
amperes. If the breaker
characteristic is to be
translated to primary
amperes, its characteristics
must lie beneath the fuse
characteristic and the heating
curve for N=1. For
unsymmetrical faults the
breaker characteristic will
shift by the same multiple as
the heating curve. If further
secondary protection is
translated to the primary,
the characteristic must lie
beneath the secondary
breaker characteristic for
the different types of faults
considered.
Fuses used at the terminals
of a delta-delta transformer
require:
1. fuse time-current curves
and
2. heat curves
if both three-phase and
phase-to-phase faults are to
be considered. This agrees
with the information
presented in the table on
Page V14-T2-17. When the
abscissa is in primary
amperes the curves are read
directly. An abscissa in
secondary amperes uses the
same curves but shifts them
from primary to secondary
amperes.

2
2

When using the current
generation of protection and
coordination computer
programs, all the factors such
as the ratios of line to
winding ratios and
transformation ratios should
be accounted for by the
software if the transformer
details are correctly entered
into the program, and it
should only be necessary to
correctly interpret the
program plots to evaluate the
levels of secondary to
primary protection, and the
level of transformer overload
protection afforded by a
selected fuse rating.
For all the coordination
diagrams discussed above,
the vertical distance between
the total clearing curve and
the safe heat curve indicates
the margin of protection
offered for different types of
faults. It should be
remembered, however, that
the transformer heat curves
illustrated in this application
data are drawn from the
reference previously cited
and they may not apply to all
transformer designs.

Typical Transformer Heat Curves
10000
8000
6000
4000

2000

1000
800
600
400

200

100
80
60
N=2A/ 3

40
Time in Seconds

2.3

N=1
20

N= 3/2

10
8

N=1/ 3

6
4

In practice, it is not always
possible to select a fuse large
enough to allow for all the
over-loading required and still
provide complete protection
for the transformer. In these
cases, the user should decide
where his priorities lie and
trade off overloading ability
for transformer protection.

2

Transformer
Full Load

Adjusted
Heat Curves

Inrush Current

0.6 0.8 1
2
4 6 8 10
20
40 60 80 100
Line Current in Multiples of Transformer Full Load (Rated) Line Current

Capacitor Application

2

Another common use of
power fuses is for the
protection of capacitor banks.
This application is unique in
that the protected
equipment, capacitors, are
designed with a zero minus
tolerance and some value
positive tolerance. For this

2
2
2
2
2
2
2
2
2
V14-T2-18

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

reason a ratio of 1.65:1 fuse
rating to full load current is
suggested for all single bank
protection. If two or more
banks are paralleled with
automatic switching, refer to
Eaton Technical Support for
fusing information.

2.3

Expulsion Fuses
Application

Repetitive Faults

The time constant of a
specific fuse, having been
obtained in terms of seconds,
gives to the general heating
and cooling curves shown
below a specific time scale.
In enables us to plot the
course of the fuse

Temperature Cycle of a Fuse During Reclosing Operation
N
2

1

3

Tr

4

A
80%

60%

Tm
Ts

40%
C
20%
B
0

p1
p2
Unit Time
Constant

1

2
3
Relative Time t/

4
t = Time in Seconds
= Time Constant
of Fuse

Curve A–Basic fuse heating curve: Tf (I-e t/ )
Curve B–Basic fuse cooling curve: Tf x e t/ )
Curve C–Temperature rise curve of fuse subjected to reclosing cycle
M–Melting time of fuse at a given fault current
N–Total clearing time of fuse at same fault current
Tm, Tn–Levels of melting temperature of fastest and of slowest fuse
(See note below)
Ts–Safe temperature level, considering service variables
Tf–Hypothetical steady-state temperature level (100%) attained if the
fuse element did not open when melting temperature was reached
but continued to be a resistance of constant value
Note: The absolute temperature at which the elements of the fastest
and of the slowest fuse melt is the same since both fuses are made
of the same material, However, Tn and Tm are different if measured
by the final temperature level if reached at a given current.

It is often desirable to
determine the performance
of fuses under repetitive
faults such as produced by
the operation of reclosing
circuit breakers. This
performance is determined
by graphically simulating the
heating and cooling
characteristics of the fuse,
which are found and
expressed by the melting
time-current curves. The
theory behind the above
implications is available upon
request, but in this section
only the practical use of those
implications will be
discussed.

Conventional E-rated fuses
can with good approximation
be regarded as bodies whose
heating and cooling
properties are described by
the basic exponential curves
A and B as shown above.
Except for being inverted, the
cooling curve is the same as
the heating curve as both
have the same time constant.
Each fuse has a specific time
constant that can be
calculated with sufficient
accuracy by the formula
θ = 0.1S2 where S is the fuse
speed ratio, that is, the
melting current at 0.1
seconds divided by the
melting current at 300 or 600
seconds. The 300 seconds
applies to fuses rated 100A or
less and the 600 seconds for
fuses rated above 100A.

100
80
60
40

QMMN
Heating

2
2

2

20

2

C
B

2

Cooling

2

2
1

2

2

A

10
8
6
4

2

2

Reclosing Circuit Breaker Fuse Coordination

Tn

Percent Temperature Rise T%

Percent Temperature Rise T%

100%

M
.75M

temperature (in percent
values) if we know the
sequence and duration of the
open and closed periods of
the recloser. This is illustrated
by curve C that is formed by
piecing together the proper
sections of curves A and B.

P-4
0.5

1

P-5
1.5

2
2.5
Relative Time t/

2
3

t = Time in Seconds
= Time Constant of Fuse
Notes: Recloser data: 400PR (cycling code A1-3CH3).
Fuse type and rating: CLT (drawout) 8.3 kV 150°C.
Fuse speed ration, S-2150/420 = 5.11.
Thermal time constant, = 0.10 S2, 2.61 seconds.
Fault current 1350A.

Next we must determine the
temperature at which the
fuse element will melt. Here
we refer to the standard timecurrent curves and find the
melting time M for specific
value of fault current. The
melting temperature Tm lies
where the ordinate to the
time M intersects curve A. It
is not necessary to know the
absolute value of this
temperature, as it is sufficient
to know its relation to the
peaks. A similar temperature
Tn can be found using the
total clearing time for the
specific fault current. What
we have then are two
temperatures where we can
state that any time the curve
C intersects the line Tm, the
fuse could operate and any
time it intersects line Tn the
fuse will definitely operate.
The gap between Tm and Tn
indicates the tolerance range
as set forth in ANSI and
NEMA® standards where
E-rated fuses are defined.

If the fuse is not to operate,
curve C must remain below
the level Tm by a safe margin.
It is common practice to
provide such a safety margin
by coordinating the breaker
with a fuse curve whose time
ordinates are 75 percent of
those of the melting curve.
Line Ts represents this
temperature in illustration
above.
Although the construction of
the temperature diagram as
outlined above basically
offers no difficulties, the
manipulation is made easier
and more accurate by putting
the graph on semi-log
coordinates as shown. On
these coordinates, the
cooling curve B becomes a
straight line.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-19

2.4
2

Expulsion Fuses
BA Type Fuses

Contents

BA Fuseholder

Description

2

Page

BA Type Fuses
Catalog Number Selection . . . . . . . . . . . . . . . .
Interrupting Ratings . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .

2
2

V14-T2-21
V14-T2-21
V14-T2-22

2
2
2
2
2
2
2

BA Type Fuses

2

Product Description

2
2
2
2
2
2
2
2
2
2
2

The refillable BA type (boric
acid) high voltage expulsion
fuse is an E-rated fuse that
can be vented (outdoor) or
enclosed (indoor). These
fuses are designed for power
applications and were
introduced by the
Westinghouse Electric
Company in the middle
1930s. The refill units have
been in continuous
production since that time
and are still available for use
in existing installations.
Mountings are no longer
available for use with BA refill
units, but a limited range of
replacement fuse holders is
still available.
New and replacement
applications should use RBA
fuses that superseded BA
fuses a number of years ago.

2
2
2
2
2
2
2
V14-T2-20

Introduction
BA power fuses provide
protection for circuits and
equipment that operate on
voltages from 7.2 to 38 kV.
When the calibrated current
responsive element melts,
the fuse reacts rapidly to
de-ionize the arc and interrupt
the circuit. On outdoor
vented installations, a
mechanical dropout action
gives a 180˚ air break. On
indoor applications, the arc
exhaust is absorbed by the
attached exhaust control
device (filter or condenser).
The fuse refill unit is of the
replaceable type rather than
the renewable type, resulting
in light weight for ease in
handling.
Construction
DE-ION® arc interruption
permits application of the BA
type power fuse over a range
of system voltages. This line
of dropout fuses carries the
boric acid principle of circuit
protection to higher voltage
ratings, and at the same time
provides short-circuit
protection for systems of
moderate capacity at a lower
cost.

Main operating parts are the
fusible element, arcing rod,
helical spring, and dry boric
acid cylinder. To prevent
warping under outdoor
conditions, a heavy glassepoxy or ceramic tube
encloses the entire assembly.
This glass-epoxy tube also
assures adequate strength to
contain the force of the arc
interruption.
Within the fuse, the current
path is maintained by tight
electrical connections. From
the top ferrule, the path is
through the extended spring
and shunt assembly; then to
the arcing rod, on through the
fusible element that is
bridged by the mechanical
strain element, and into the
bottom ferrule. When the
fuse element melts, the
arcing rod is pulled upward
drawing the arc into the boric
acid cylinder. As it strikes,
intense heat from the arc
decomposes the compressed
boric acid powder.
Decomposition of the dry
boric acid forms water vapor
and boric acid anhydride. The
electrical interruption is
caused by the steam cooling
and de-ionizing the arc as it is
drawn through the cylinder by
the action of the spring and
rod.

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Operation
BA type fuses are of the
refillable type. When a fuse
operates due to a fault blown,
the fuse holder is removed
with from the mounting.
After replacement of the refill
unit, the fuse holder can be
reinserted into the fuse
mounting.
Application
BA fuses are applied in utility
and industrial high voltage
power systems for
protecting:
●
●

●
●

Power transformers
Feeder circuit
sectionalizing
Distribution transformers
Potential transformers

Ratings
●
8.3 to 38 kV
●
0.5E to 400E Amperes

Expulsion Fuses
BA Type Fuses

2.4

Catalog Number Selection

2

BA Fuse Units

2

15 BA2 100E
Maximum kV
8 = 8.3 kV
15 = 15.5 kV
25 = 25.5 kV
38 = 38 kV

Amperes
Rating
0.5
65E
5E
80E
7E
100E
10E
125E
20E
150E
25E
200E
30E
250E
40E
300E
50E
400E

Type
BA2
BA4

2
2

Hardware
NH

2
2
2
2
2

Interrupting Ratings

2

BA Fuse Interrupting Ratings

2

Refill Maximum
Rated Voltage
Rating kV

Maximum
System
Voltage kV

Vented or with
Filter rms
Symmetrical kA

With Condenser rms
Symmetrical kA

8.3

2.75

17.5

10.0

—

5.5

17.5

10.0

—

8.3

16.0

10.0

15.5

15.5

12.5

8.0

25.8

25.8

10.0

6.3

38

38

6.3

5.0

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-21

2.4

Expulsion Fuses
BA Type Fuses

2

Product Selection

2

BA2 Type Expulsion Fuse Refill Units
Voltage (kV)

Performance Curves

Nominal

Maximum

Ampere Rating

Catalog Number

Approximate Shipping
Weight Lbs (kg)

2

7.2

8.3

0.5

8BA2-.5

1.0 (0.45)

TC28115801

TC28021601

7.2

8.3

5E

8BA2-5E

1.0 (0.45)

TC28115801

TC28021601

2

7.2

8.3

7E

8BA2-7E

1.0 (0.45)

TC28115801

TC28021601

7.2

8.3

10E

8BA2-10E

1.0 (0.45)

TC28115801

TC28021601

7.2

8.3

15E

8BA2-15E

1.0 (0.45)

TC28115801

TC28021601

2

7.2

8.3

20E

8BA2-20E

1.0 (0.45)

TC28115801

TC28021601

7.2

8.3

25E

8BA2-25E

1.0 (0.45)

TC28115801

TC28021601

2

7.2

8.3

30E

8BA2-30E

1.0 (0.45)

TC28115801

TC28021601

7.2

8.3

40E

8BA2-40E

1.0 (0.45)

TC28115801

TC28021601

7.2

8.3

50E

8BA2-50E

1.0 (0.45)

TC28115801

TC28021601

7.2

8.3

65E

8BA2-65E

1.0 (0.45)

TC28115801

TC28021601

7.2

8.3

80E

8BA2-80E

1.0 (0.45)

TC28115801

TC28021601

2

7.2

8.3

100E

8BA2-100E

1.0 (0.45)

TC28115801

TC28021601

7.2

8.3

125E

8BA2-125E

1.0 (0.45)

TC28115801

TC28021601

2

7.2

8.3

150E

8BA2-150E

1.0 (0.45)

TC28115801

TC28021601

7.2

8.3

200E

8BA2-200E

1.0 (0.45)

TC28115801

TC28021601

14.4

15.5

0.5

15BA2-.5

1.2 (0.55)

TC28115801

TC28021601

14.4

15.5

5E

15BA2-5E

1.2 (0.55)

TC28115801

TC28021601

14.4

15.5

7E

15BA2-7E

1.2 (0.55)

TC28115801

TC28021601

2

14.4

15.5

10E

15BA2-10E

1.2 (0.55)

TC28115801

TC28021601

14.4

15.5

15E

15BA2-15E

1.2 (0.55)

TC28115801

TC28021601

2

14.4

15.5

20E

15BA2-20E

1.2 (0.55)

TC28115801

TC28021601

14.4

15.5

25E

15BA2-25E

1.2 (0.55)

TC28115801

TC28021601

14.4

15.5

30E

15BA2-30E

1.2 (0.55)

TC28115801

TC28021601

14.4

15.5

40E

15BA2-40E

1.2 (0.55)

TC28115801

TC28021601

14.4

15.5

50E

15BA2-50E

1.2 (0.55)

TC28115801

TC28021601

2

14.4

15.5

65E

15BA2-65E

1.2 (0.55)

TC28115801

TC28021601

14.4

15.5

80E

15BA2-80E

1.2 (0.55)

TC28115801

TC28021601

2

14.4

15.5

100E

15BA2-100E

1.2 (0.55)

TC28115801

TC28021601

14.4

15.5

125E

15BA2-125E

1.2 (0.55)

TC28115801

TC28021601

14.4

15.5

150E

15BA2-150E

1.2 (0.55)

TC28115801

TC28021601

14.4

15.5

200E

15BA2-200E

1.2 (0.55)

TC28115801

TC28021601

2

2

2
2

2
2

2
2

2
2
2
2
2
2
2
2
2
2

V14-T2-22

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Minimum Melting

Total Clearing

Expulsion Fuses
BA Type Fuses

2.4

BA2 Type Expulsion Fuse Refill Units, continued
Voltage (kV)

2

Performance Curves

Nominal

Maximum

Ampere Rating

Catalog Number

Approximate Shipping
Weight Lbs (kg)

Minimum Melting

Total Clearing

23

25.5

0.5

25BA2-.5

1.5 (0.7)

TC28115801

TC28021601

23

25.5

5E

25BA2-5E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

7E

25BA2-7E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

10E

25BA2-10E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

15E

25BA2-15E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

20E

25BA2-20E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

25E

25BA2-25E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

30E

25BA2-30E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

40E

25BA2-40E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

50E

25BA2-50E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

65E

25BA2-65E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

80E

25BA2-80E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

100E

25BA2-100E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

125E

25BA2-125E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

150E

25BA2-150E

1.5 (0.7)

TC28115801

TC28021601

23

25.5

200E

25BA2-200E

1.5 (0.7)

TC28115801

TC28021601

34.5

38

0.5

38BA2-.5

1.8 (0.82)

TC28115801

TC28021601

34.5

38

5E

38BA2-5E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

7E

38BA2-7E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

10E

38BA2-10E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

15E

38BA2-15E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

20E

38BA2-20E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

25E

38BA2-25E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

30E

38BA2-30E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

40E

38BA2-40E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

50E

38BA2-50E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

65E

38BA2-65E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

80E

38BA2-80E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

100E

38BA2-100E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

125E

38BA2-125E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

150E

38BA2-150E

1.8 (0.82)

TC28115801

TC28021601

34.5

38

200E

38BA2-200E

1.8 (0.82)

TC28115801

TC28021601

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-23

2.4
2
2
2

Expulsion Fuses
BA Type Fuses

BA4 Type Expulsion Fuse Refill Units
Voltage (kV)

Performance Curves

Nominal

Maximum

Ampere Rating

Catalog Number

Approximate Shipping
Weight Lbs (kg)

7.2

8.3

0.5

8BA4-.5

2 (0.9)

Minimum Melting

Total Clearing

TC28021201

TC28021401

7.2

8.3

5E

8BA4-5E

2 (0.9)

TC28021201

TC28021401

2

7.2

8.3

7E

8BA4-7E

2 (0.9)

TC28021201

TC28021401

7.2

8.3

10E

8BA4-10E

2 (0.9)

TC28021201

TC28021401

2

7.2

8.3

15E

8BA4-15E

2 (0.9)

TC28021201

TC28021401

2

7.2

8.3

20E

8BA4-20E

2 (0.9)

TC28021201

TC28021401

7.2

8.3

25E

8BA4-25E

2 (0.9)

TC28021201

TC28021401

2
2
2
2

7.2

8.3

30E

8BA4-30E

2 (0.9)

TC28021201

TC28021401

7.2

8.3

40E

8BA4-40E

2 (0.9)

TC28021201

TC28021401

7.2

8.3

50E

8BA4-50E

2 (0.9)

TC28021201

TC28021401

7.2

8.3

65E

8BA4-65E

2 (0.9)

TC28021201

TC28021401

7.2

8.3

80E

8BA4-80E

2 (0.9)

TC28021201

TC28021401

7.2

8.3

100E

8BA4-100E

2 (0.9)

TC28021201

TC28021401

7.2

8.3

125E

8BA4-125E

2 (0.9)

TC28021201

TC28021401

2

7.2

8.3

150E

8BA4-150E

2 (0.9)

TC28021201

TC28021401

7.2

8.3

200E

8BA4-200E

2 (0.9)

TC28021201

TC28021401

2

7.2

8.3

250E

8BA4-250E

2 (0.9)

TC28021201

TC28021401

2

7.2

8.3

300E

8BA4-300E

2 (0.9)

TC28021201

TC28021401

7.2

8.3

400E

8BA4-400E

2 (0.9)

TC28021201

TC28021401

2
2
2
2
2

14.4

15.5

0.5

15BA4-.5

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

5E

15BA4-5E

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

7E

15BA4-7E

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

10E

15BA4-10E

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

15E

15BA4-15E

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

20E

15BA4-20E

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

25E

15BA4-25E

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

30E

15BA4-30E

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

40E

15BA4-40E

2.5 (1.15)

TC28021201

TC28021401

2

14.4

15.5

50E

15BA4-50E

2.5 (1.15)

TC28021201

TC28021401

2

14.4

15.5

65E

15BA4-65E

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

80E

15BA4-80E

2.5 (1.15)

TC28021201

TC28021401

2

14.4

15.5

100E

15BA4-100E

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

125E

15BA4-125E

2.5 (1.15)

TC28021201

TC28021401

2
2
2

14.4

15.5

150E

15BA4-150E

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

200E

15BA4-200E

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

250E

15BA4-250E

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

300E

15BA4-300E

2.5 (1.15)

TC28021201

TC28021401

14.4

15.5

400E

15BA4-400E

2.5 (1.15)

TC28021201

TC28021401

2
2
2
2
2
2
V14-T2-24

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
BA Type Fuses

2.4

BA4 Type Expulsion Fuse Refill Units, continued
Voltage (kV)
Nominal

2

Performance Curves
Maximum

Ampere Rating

Catalog Number

Approximate Shipping
Weight Lbs (kg)

Minimum Melting

Total Clearing

23

25.5

0.5

25BA4-.5

3.5 (1.6)

TC28021201

TC28021401

23

25.5

5E

25BA4-5E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

7E

25BA4-7E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

10E

25BA4-10E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

15E

25BA4-15E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

20E

25BA4-20E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

25E

25BA4-25E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

30E

25BA4-30E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

40E

25BA4-40E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

50E

25BA4-50E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

65E

25BA4-65E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

80E

25BA4-80E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

100E

25BA4-100E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

125E

25BA4-125E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

150E

25BA4-150E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

200E

25BA4-200E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

250E

25BA4-250E

3.5 (1.6)

TC28021201

TC28021401

23

25.5

300E

25BA4-300E

3.5 (1.6)

TC28021201

TC28021401

34.5

38

0.5

38BA4-.5

4 (1.8)

TC28021201

TC28021401

34.5

38

5E

38BA4-5E

4 (1.8)

TC28021201

TC28021401

34.5

38

7E

38BA4-7E

4 (1.8)

TC28021201

TC28021401

34.5

38

10E

38BA4-10E

4 (1.8)

TC28021201

TC28021401

34.5

38

15E

38BA4-15E

4 (1.8)

TC28021201

TC28021401

34.5

38

20E

38BA4-20E

4 (1.8)

TC28021201

TC28021401

34.5

38

25E

38BA4-25E

4 (1.8)

TC28021201

TC28021401

34.5

38

30E

38BA4-30E

4 (1.8)

TC28021201

TC28021401

34.5

38

40E

38BA4-40E

4 (1.8)

TC28021201

TC28021401

34.5

38

50E

38BA4-50E

4 (1.8)

TC28021201

TC28021401

34.5

38

65E

38BA4-65E

4 (1.8)

TC28021201

TC28021401

34.5

38

80E

38BA4-80E

4 (1.8)

TC28021201

TC28021401

34.5

38

100E

38BA4-100E

4 (1.8)

TC28021201

TC28021401

34.5

38

125E

38BA4-125E

4 (1.8)

TC28021201

TC28021401

34.5

38

150E

38BA4-150E

4 (1.8)

TC28021201

TC28021401

34.5

38

200E

38BA4-200E

4 (1.8)

TC28021201

TC28021401

34.5

38

250E

38BA4-250E

4 (1.8)

TC28021201

TC28021401

34.5

38

300E

38BA4-300E

4 (1.8)

TC28021201

TC28021401

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-25

2.4
2

Expulsion Fuses
BA Type Fuses

BA2 Type Expulsion Fuse Fuse Holders and Exhaust Control Devices



Ampere Rating

Non-Disconnect Fuse Holder
Catalog Number

Exhaust Control Device
Filter
Condenser
Catalog Number
Catalog Number

2

Voltage (kV)
Nominal

2

7.2

8.3

0.5–200E

8BA2-NH

RBA2-FLTR

14.4

15.5

0.5–200E

15BA2-NH

RBA2-FLTR

RBA2-COND

23

25.5

0.5–200E

—

RBA2-FLTR

RBA2-COND

34.5

38

0.5–200E

—

RBA2-FLTR

RBA2-COND

2
2
2
2
2
2
2
2
2

Maximum

BA4 Type Expulsion Fuse Fuse Holders and Exhaust Control Devices



Ampere Rating

Non-Disconnect Fuse Holder
Catalog Number

Exhaust Control Device
Filter
Condenser
Catalog Number
Catalog Number

0.5–400E

8BA4-NH

RBA4-FLTR

15.5

0.5–400E

15BA4-NH

RBA4-FLTR

RBA4-COND

25.5

0.5–300E

—

RBA4-FLTR

RBA4-COND

38

0.5–300E

—

RBA4-FLTR

RBA4-COND

Voltage (kV)
Nominal

Maximum

7.2

8.3

14.4
23
34.5

Notes
 Available as replacements in exiting installations. For new installations, use RBA fuse assemblies.
 Mounting no longer available. If mounting is required, convert installation to RBA fuse assemblies.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V14-T2-26

RBA2-COND

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

RBA4-COND

Expulsion Fuses
DBA Type Fuses

2.5

Contents

DBA Fuse

Description

Page

DBA Type Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection. . . . . . . . . . . . . . . . .
Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .

V14-T2-27
V14-T2-32
V14-T2-32
V14-T2-33

2
2
2
2
2
2
2
2
2
2
2

DBA Type Fuses

2

Product Description
The DBA type (dropout, boric
acid) high voltage expulsion
fuse is an E-rated, vented
device designed for power
applications.
Introduction
The DBA power fuse
provides double protection
for circuits and equipment
that operate on voltages from
7.2 to 145 kV. The fuse has
instant acting DE-ION circuit
interruption and almost
simultaneously, a mechanical
dropout action gives a 180˚ air
break. The fuse unit is of the
replaceable type rather than
the renewable type, resulting
in light weight for ease in
handling.

Construction
DE-ION arc interruption
permits application of the DBA
type power fuse over a wide
range of system voltages. This
line of dropout fuses carries
the boric acid principle of
circuit protection to higher
voltage ratings, and at the
same time provides at lower
cost short-circuit protection for
systems of moderate capacity.
Principle parts of the DBA fuse
unit are shown in the cross
section illustration on this
page. Main operating parts are
the fusible element, arcing
rod, helical spring, and dry
boric acid cylinder. To prevent
warping under outdoor
conditions, a heavy Micarta
tube encloses the entire
assembly. This Micarta tube
also assures adequate
strength to contain the force of
the arc interruption.

Within the fuse unit, the
current path is maintained by
tight electrical connections.
From the top ferrule, the path
is to the copper tube spring
shunt; then to the arcing rod
collar and the arcing rod, on
through the fusible element
that is bridged by the strain
element, and into the bottom
ferrule. The copper spring
shunt and the arcing rod
collar are firmly held together
by the contact finger spring.
When the fuse element is
blown, the arcing rod is pulled
upward drawing the arc into
the boric acid cylinder. The
spring shunt contact fingers
close in on the rod to
maintain the electrical path.
Intense heat from the arc, as
it strikes, decomposes the
compressed boric acid
powder.

DBA Fuse Construction
Retaining Ring
Top Ferrule

Micarta Tube

Copper Tube
Spacing Shunt

www.comoso.com

2
2
2

Arcing Rod End
Helical Spring

2
2
2

Compressed Boric
Acid Powder
Arcing Rod

2
2
2
2
2
2

Bottom Ferrule

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

2
2

Decomposition of the dry boric
acid forms water vapor and
boric acid anhydride. The
electrical interruption is caused
by the steam de-ionizing the
arc as it is drawn through the
cylinder by action of the spring
and rod.
The arcing rod is prevented
from falling back into the fuse
until after interruption by a
friction stop just inside the top
ferrule.

2

Strain Element
Fusible Element

2
2
2

V14-T2-27

2.5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Expulsion Fuses
DBA Type Fuses

Operation
The DBA type fuse unit is of
the replaceable type rather
than the renewable type.
When the fuse has blown and
drop-out completed, the
entire unit is removed with a
switch stick. After
replacement of the blown
unit, it is closed back into
place with the switch stick.
In replacing the blown fuse,
the end fittings are removed
and clamped on a new fuse.
End fittings consist of an
operating eye at the top and
hinge lifting eye at the
bottom. The two fittings have
different shapes and are
keyed with different
projections. Fittings are
simple to remove or replace,
and cannot be reversed since
the keys insure quick, correct
alignment.
DE-ION circuit interruption
by action of the boric acid
fuse unit is followed
simultaneously by a
mechanical drop-out action.
When closing the fuse unit
with the switch stick, the
ejector casting located under
the sleet hood, compresses
the ejector spring. Under fault
conditions the fuse element
melts, the helical spring pulls
the arcing rod and arc through
the cylinder. The upper end of
the arcing rod drives through
a small hole in the top of the
ferrule of the fuse unit and
strikes the trigger-releasing
ejector. The trigger operates
and causes the ejector spring

to force the ejector casting
against the fuse assembly
forcing it outward to swing
through a 180˚ arc into a dropout position. Drop-out action
provides immediate visual
indication that the particular
circuit in which the fuse is
connected has been
interrupted. The additional
drop-out break insulates the
fault from the feeders with an
air gap of at least one foot on
lower voltage system and up
to six feet on higher voltage
systems.
This air break eliminates any
possibility of carbonized fuse
parts breaking down to allow
leakage or another fault.
Since drop-out action takes
place after current
interruption within the boric
acid cylinder, burning or
arcing at the contact surfaces
is eliminated.
Application
The DBA fuse is applicable in
utility and industrial high voltage
power systems for protecting:
●
●
●
●

Power transformers
Feeder circuit sectionalizing
Distribution transformers
Potential transformers

Ratings
●
8.3 to 145 kV
●
0.5E to 200E Amperes

The power fuse is an inherently
fast circuit-interrupting device.
This must be taken into account
when determining the required
short-circuit interrupting rating
of a fuse.
The boric acid power fuse will
interrupt currents of shortcircuit magnitude in
approximately 1/2 cycle
measured from the instant of
short-circuit. During this 1/2
cycle, the short-circuit current
may be much higher than the
sustained rms short-circuit
current of the system at that
point. The fuse must be
capable of safely interrupting
this transient current that might
exist at the instant the fuse
operates.
In an alternating current circuit
containing inductance, a
sudden change in the AC
current is accompanied by a
transient DC component that is
a function of the AC current
before and after the change and
the point on the cycle at that
the change occurs. The
decrement of the transient is a
function of the inductance and
resistance or losses of the
circuit.
If a short is suddenly
established on a circuit, the DC
component can have a
maximum peak value equal to
the crest of the 60 cycle shortcircuit current of the system.

2
2
2
2
2
2
2
2
2
V14-T2-28

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

This maximum transient is
obtained if the fault occurs at
voltage zero. Due to the system
losses, this DC component will
die out to a low value in a few
cycles. However, a fuse
normally interrupts a shortcircuit in 1/2 cycle, and this DC
component of current must be
taken into consideration in
rating the fuse. If the
decrement of DC component in
this half cycle is neglected, the
rms value of current for the
totally asymmetrical condition
would be 1.73 times the rms
symmetrical value of the 60
cycle component.
Experience has shown that
there is some decrement in this
first half cycle and also that the
current is limited somewhat by
the arc drop in the fuse. For this
reason, a ratio of 1.6 has been
selected between the rms
asymmetrical current the fuse
must be designed to interrupt,
and the rms short-circuit of the
system on which the fuse is to
be used. This instantaneous
rms asymmetrical value of
short-circuit current, which the
fuse must be designed to
interrupt, is often referred to as
the rms symmetrical value
including the DC component.
The asymmetrical value is
obtained by multiplying the
symmetrical value by 1.6. The
symmetrical value of shortcircuit current on a three-phase
system is determined by
dividing the available threephase, short-circuit kVA by the
product of the system voltage
and 1/ 3 .

2.5

Expulsion Fuses
DBA Type Fuses

Instructions for DBA Type Fuse Units 8.3 kV to 145 kV

2

Installation of Replacement Fuses

Maintenance

DBA fuse units are available in
two classifications, DBA-1 and
DBA-2 and are used for utilitytype applications from 8.3 kV
through 145 kV.

General maintenance
instructions are published in the
IEEE Std. C-37.48™-1973.
Inspection of the fuse
mounting should include
checking the gauge distance
“S” (see the figures on Pages
V14-T2-30 and V14-T2-31)
and the operation of the latch
mechanism.

Remove fuses from all three
phases and replace with new or
tested units. Fuses having been
involved in a fault but not blown
should be tested by resistance
measurements to ascertain that
they are suitable for continued
service. Resistance limits are
available on request.
Prior to installation, it is
advisable to check the
functioning of the mounting as
follows:
1. Remove fuse fittings
from hinge casting
(see the figures on
Pages V14-T2-30 and
V14-T2-31) and mount
on a suitable fuse unit as
shown in the figure on
this page.
2. Check gauging distance
“S” between center of
guide pin in latch housing
and bottom of socket in
hinge casting as
illustrated in the figures
on Pages V14-T2-30 and
V14-T2-31. Dimension
“S” must measure the
same on both sides of
the mounting. If
dimension “S” is found
to be incorrect, adjust it
by using the clearances
provided in the bolt
holes (see the figures on
Pages V14-T2-30 and
V14-T2-31).

3. Put the suitable fuse unit
equipped with fittings in
the mounting. Check
operation of latch
assembly by closing and
opening the fuse as
shown in the figures on
Pages V14-T2-30 and
V14-T2-31).
DBA-1 fuses up to 69 kV as
well as DBA-2 fuses up to 46
kV can be lifted into the hinge
casting by means of
conventional all-purpose switch
sticks. For lifting heavier fuses
into the hinge, a switch stick
about one foot shorter than
the distance from ground
level to the fuse hinge is
recommended. This switch
stick should be held
approximately vertical as
shown in the figures on Pages
V14-T2-30 and V14-T2-31.
For the closing-in or
disconnecting operation, a
switch stick of at least four foot
greater length should be
employed. Insert the switch
stick pin into the eye of the fuse
fitting from the right-hand side
and have it form an angle of at
least 35˚ with the fuse.

2
2
2
2
2
2

Fuse Unit With Fittings

2

Clamp Ring

2
2
2

Upper
Eye
Casting

Locating Pin

2

Nameplate

2
2

Fuse
Unit

2

A
(See table below)

Lower
Eye
Casting

2
2

Fuse should be closed in with a
sharp thrust. A similar impactlike pull is required to open the
fuse. After the latch contacts
have parted, the fuse may be
allowed to disengage itself
from the switch stick and drop
out in a normal manner.

2
2
2
2
2
Locating Pin

kV

2
Dimensions in Inches (mm)
DBA-1

2

DBA-2

8.3

13.5 (342.9)

—

15.5

17.0 (431.8)

—

25.5

21.5 (546.1)

—

38

28.5 (723.9)

28.13 (714.5)

48.3

34.0 (863.6)

33.63 (854.2)

69

43.88 (1,114.6)

43.63 (1,108.2)

92

—

52.0 (1,320.8)

121

—

62.0 (1,574.8)

145

—

72.0 (1,828.8)

2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-29

2.5
2

Expulsion Fuses
DBA Type Fuses

Insulator Spacing
Approximate Dimensions in Inches (mm)

2
2
2
2
2
2
2
2
2
2

7.2 to 46 kV

69 kV

92 to 138 kV

2

kV

Dimension C

Dimension S

Dimension C

2

7.2

13.63 (346.2)

15.25 (387.4)

—

—

15

17.13 (435.1)

18.75 (476.3)

—

—

23

21.63 (549.4)

23.25 (590.6)

—

—

34.5

28.63 (727.2)

30.25 (768.4)

27.88 (708.2)

—

46

34.13 (866.9)

35.75 (908.1)

33.38 (847.9)

—

DBA-1

2
2
2
2
2
2

Dimension S

DBA-2

69

44.00 (1117.6)

45.63 (1159.0)

43.38 (1101.9)

—

92

—

—

51.75 (1314.5)

—

115

—

—

61.75 (1568.5)

—

138

—

—

71.75 (1822.5)

—

Hinge Assembly

2
2
2
2
2
2

DBA-1
8.3 to 69 kV

2

DBA-2
38 to 72.5 kV

2
DBA-2
92 to 145 kV

2
2
2
V14-T2-30

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
DBA Type Fuses

2.5

Spacer Adjustment

2
2
2
2
2
2
2
2

Procedure

2

1. Loosen all four through bolts.
2. Turn adjusting nut the desired amount.

2

3. Retighten all four through bolts.

2
2

Switch Stick Operation

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-31

2.5
2
2

Expulsion Fuses
DBA Type Fuses

Catalog Number Selection
DBA Fuse Units

15 DBA2 100E

2
Maximum kV
8 = 8.3 kV
15 = 15.5 kV
25 = 25.5 kV
38 = 38 kV
48 = 48 kV
72 = 72 kV
92 = 92 kV
121 = 121 kV
145 = 145 kV

2
2
2
2

Type
DBA1
DBA2

2

Ampere
Rating
0.5
40E
3
50E
5E
65E
7E
80E
10E
100E
15E
125E
20E
150E
25E
200E
30E

2
2

Interrupting Ratings

2

DBA Fuse Interrupting Ratings

2
2

Fuse Unit Maximum
Voltage Rating kV

Maximum System
Voltage kV

DBA-1 rms
Symmetrical kA

DBA-2 rms
Symmetrical kA

8.3

2.75

6.3

—

—

5.5

6.3

—

—

8.3

6.3

—

2

15.5

15.5

6.3

—

2

25.8

25.8

6.3

12.5

38

38

5.0

12.5

2

48

48

4.0

12.5

72

72

—

10.0

2

92

92

—

6.3

121

121

—

5.0

145

145

—

4.0

2
2
2
2
2
2
2
2
2
2
2
2
2

V14-T2-32

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
DBA Type Fuses

2.5

Product Selection

2

DBA-1 Type Expulsion Fuse Units
Voltage (kV)
Nominal

2

Performance Curves
Maximum

Ampere Rating

Approximate Shipping
Weight Lbs (kg)

Catalog Number

Minimum Melting

Total Clearing

7.2

8.3

0.5

8DBA1-0.5

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

3

8DBA1-3

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

5E

8DBA1-5E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

7E

8DBA1-7E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

10E

8DBA1-10E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

15E

8DBA1-15E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

20E

8DBA1-20E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

25E

8DBA1-25E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

30E

8DBA1-30E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

40E

8DBA1-40E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

50E

8DBA1-50E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

65E

8DBA1-65E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

80E

8DBA1-80E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

100E

8DBA1-100E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

125E

8DBA1-125E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

150E

8DBA1-150E

1.5 (0.7)

TC45935101

TC45935201

7.2

8.3

200E

8DBA1-200E

1.5 (0.7)

TC45935101

TC45935201

14.4

15.5

0.5

15DBA1-0.5

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

3

15DBA1-3

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

5E

15DBA1-5E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

7E

15DBA1-7E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

10E

15DBA1-10E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

15E

15DBA1-15E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

20E

15DBA1-20E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

25E

15DBA1-25E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

30E

15DBA1-30E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

40E

15DBA1-40E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

50E

15DBA1-50E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

65E

15DBA1-65E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

80E

15DBA1-80E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

100E

15DBA1-100E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

125E

15DBA1-125E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

150E

15DBA1-150E

2.1 (1.0)

TC45935101

TC45935201

14.4

15.5

200E

15DBA1-200E

2.1 (1.0)

TC45935101

TC45935201

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-33

2.5
2

Expulsion Fuses
DBA Type Fuses

DBA-1 Type Expulsion Fuse Units, continued
Voltage (kV)

Performance Curves

Nominal

Maximum

Ampere Rating

Catalog Number

Approximate Shipping
Weight Lbs (kg)

Minimum Melting

Total Clearing

23

25.5

0.5

25DBA1-0.5

3.1 (1.4)

TC45935101

TC45935201

23

25.5

3

25DBA1-3

3.1 (1.4)

TC45935101

TC45935201

23

25.5

5E

25DBA1-5E

3.1 (1.4)

TC45935101

TC45935201

23

25.5

7E

25DBA1-7E

3.1 (1.4)

TC45935101

TC45935201

23

25.5

10E

25DBA1-10E

3.1 (1.4)

TC45935101

TC45935201

2

23

25.5

15E

25DBA1-15E

3.1 (1.4)

TC45935101

TC45935201

23

25.5

20E

25DBA1-20E

3.1 (1.4)

TC45935101

TC45935201

2

23

25.5

25E

25DBA1-25E

3.1 (1.4)

TC45935101

TC45935201

23

25.5

30E

25DBA1-30E

3.1 (1.4)

TC45935101

TC45935201

23

25.5

40E

25DBA1-40E

3.1 (1.4)

TC45935101

TC45935201

2

23

25.5

50E

25DBA1-50E

3.1 (1.4)

TC45935101

TC45935201

23

25.5

65E

25DBA1-65E

3.1 (1.4)

TC45935101

TC45935201

2

23

25.5

80E

25DBA1-80E

3.1 (1.4)

TC45935101

TC45935201

23

25.5

100E

25DBA1-100E

3.1 (1.4)

TC45935101

TC45935201

23

25.5

125E

25DBA1-125E

3.1 (1.4)

TC45935101

TC45935201

2

23

25.5

150E

25DBA1-150E

3.1 (1.4)

TC45935101

TC45935201

23

25.5

200E

25DBA1-200E

3.1 (1.4)

TC45935101

TC45935201

2

34.5

38

0.5

38DBA1-0.5

4.2 (1.9)

TC45935101

TC45935201

34.5

38

3

38DBA1-3

4.2 (1.9)

TC45935101

TC45935201

34.5

38

5E

38DBA1-5E

4.2 (1.9)

TC45935101

TC45935201

34.5

38

7E

38DBA1-7E

4.2 (1.9)

TC45935101

TC45935201

34.5

38

10E

38DBA1-10E

4.2 (1.9)

TC45935101

TC45935201

34.5

38

15E

38DBA1-15E

4.2 (1.9)

TC45935101

TC45935201

34.5

38

20E

38DBA1-20E

4.2 (1.9)

TC45935101

TC45935201

34.5

38

25E

38DBA1-25E

4.2 (1.9)

TC45935101

TC45935201

34.5

38

30E

38DBA1-30E

4.2 (1.9)

TC45935101

TC45935201

2
2
2
2

2

2

2
2
2
2
2
2

34.5

38

40E

38DBA1-40E

4.2 (1.9)

TC45935101

TC45935201

34.5

38

50E

38DBA1-50E

4.2 (1.9)

TC45935101

TC45935201

34.5

38

65E

38DBA1-65E

4.2 (1.9)

TC45935101

TC45935201

2

34.5

38

80E

38DBA1-80E

4.2 (1.9)

TC45935101

TC45935201

2

34.5

38

100E

38DBA1-100E

4.2 (1.9)

TC45935101

TC45935201

34.5

38

125E

38DBA1-125E

4.2 (1.9)

TC45935101

TC45935201

2

34.5

38

150E

38DBA1-150E

4.2 (1.9)

TC45935101

TC45935201

34.5

38

200E

38DBA1-200E

4.2 (1.9)

TC45935101

TC45935201

2
2
2
2
2
2
2
2
V14-T2-34

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
DBA Type Fuses

2.5

DBA-1 Type Expulsion Fuse Units, continued
Voltage (kV)
Nominal

2

Performance Curves
Maximum

Ampere Rating

Approximate Shipping
Weight Lbs (kg)

Catalog Number

Minimum Melting

Total Clearing

46

48

0.5

48DBA1-0.5

6.5 (3.0)

TC45935101

TC45935301

46

48

3

48DBA1-3

6.5 (3.0)

TC45935101

TC45935301

46

48

5E

48DBA1-5E

6.5 (3.0)

TC45935101

TC45935301

46

48

7E

48DBA1-7E

6.5 (3.0)

TC45935101

TC45935301

46

48

10E

48DBA1-10E

6.5 (3.0)

TC45935101

TC45935301

46

48

15E

48DBA1-15E

6.5 (3.0)

TC45935101

TC45935301

46

48

20E

48DBA1-20E

6.5 (3.0)

TC45935101

TC45935301

46

48

25E

48DBA1-25E

6.5 (3.0)

TC45935101

TC45935301

46

48

30E

48DBA1-30E

6.5 (3.0)

TC45935101

TC45935301

46

48

40E

48DBA1-40E

6.5 (3.0)

TC45935101

TC45935301

46

48

50E

48DBA1-50E

6.5 (3.0)

TC45935101

TC45935301

46

48

65E

48DBA1-65E

6.5 (3.0)

TC45935101

TC45935301

46

48

80E

48DBA1-80E

6.5 (3.0)

TC45935101

TC45935301

46

48

100E

48DBA1-100E

6.5 (3.0)

TC45935101

TC45935301

46

48

125E

48DBA1-125E

6.5 (3.0)

TC45935101

TC45935301

46

48

150E

48DBA1-150E

6.5 (3.0)

TC45935101

TC45935301

46

48

200E

48DBA1-200E

6.5 (3.0)

TC45935101

TC45935301

69

72

0.5

72DBA1-0.5

7.1 (3.25)

TC45935101

TC45935301

69

72

3

72DBA1-3

7.1 (3.25)

TC45935101

TC45935301

69

72

5E

72DBA1-5E

7.1 (3.25)

TC45935101

TC45935301

69

72

7E

72DBA1-7E

7.1 (3.25)

TC45935101

TC45935301

69

72

10E

72DBA1-10E

7.1 (3.25)

TC45935101

TC45935301

69

72

15E

72DBA1-15E

7.1 (3.25)

TC45935101

TC45935301

69

72

20E

72DBA1-20E

7.1 (3.25)

TC45935101

TC45935301

69

72

25E

72DBA1-25E

7.1 (3.25)

TC45935101

TC45935301

69

72

30E

72DBA1-30E

7.1 (3.25)

TC45935101

TC45935301

69

72

40E

72DBA1-40E

7.1 (3.25)

TC45935101

TC45935301

69

72

50E

72DBA1-50E

7.1 (3.25)

TC45935101

TC45935301

69

72

65E

72DBA1-65E

7.1 (3.25)

TC45935101

TC45935301

69

72

80E

72DBA1-80E

7.1 (3.25)

TC45935101

TC45935301

69

72

100E

72DBA1-100E

7.1 (3.25)

TC45935101

TC45935301

69

72

125E

72DBA1-125E

7.1 (3.25)

TC45935101

TC45935301

69

72

150E

72DBA1-150E

7.1 (3.25)

TC45935101

TC45935301

69

72

200E

72DBA1-200E

7.1 (3.25)

TC45935101

TC45935301

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-35

2.5
2
2
2

Expulsion Fuses
DBA Type Fuses

DBA-2 Type Expulsion Fuse Units
Voltage (kV)

Performance Curves

Nominal

Maximum

Ampere Rating

Catalog Number

Approximate Shipping
Weight Lbs (kg)

34.5

38

0.5

38DBA2-.5

10 (4.6)

Minimum Melting

Total Clearing

TC45935101

TC45935301

34.5

38

3

38DBA2-3

10 (4.6)

TC45935101

TC45935301

2

34.5

38

5E

38DBA2-5E

10 (4.6)

TC45935101

TC45935301

34.5

38

7E

38DBA2-7E

10 (4.6)

TC45935101

TC45935301

2

34.5

38

10E

38DBA2-10E

10 (4.6)

TC45935101

TC45935301

2

34.5

38

15E

38DBA2-15E

10 (4.6)

TC45935101

TC45935301

34.5

38

20E

38DBA2-20E

10 (4.6)

TC45935101

TC45935301

2
2
2
2

34.5

38

25E

38DBA2-25E

10 (4.6)

TC45935101

TC45935301

34.5

38

30E

38DBA2-30E

10 (4.6)

TC45935101

TC45935301

34.5

38

40E

38DBA2-40E

10 (4.6)

TC45935101

TC45935301

34.5

38

50E

38DBA2-50E

10 (4.6)

TC45935101

TC45935301

34.5

38

65E

38DBA2-65E

10 (4.6)

TC45935101

TC45935301

34.5

38

80E

38DBA2-780E

10 (4.6)

TC45935101

TC45935301

34.5

38

100E

38DBA2-100E

10 (4.6)

TC45935101

TC45935301

2

34.5

38

125E

38DBA2-125E

10 (4.6)

TC45935101

TC45935301

34.5

38

150E

38DBA2-150E

10 (4.6)

TC45935101

TC45935301

2

34.5

38

200E

38DBA2-200E

10 (4.6)

TC45935101

TC45935301

2

46

48

0.5

48DBA2-.5

12 (5.5)

TC45935101

TC45935301

46

48

3

48DBA2-3

12 (5.5)

TC45935101

TC45935301

2
2

46

48

5E

48DBA2-5E

12 (5.5)

TC45935101

TC45935301

46

48

7E

48DBA2-7E

12 (5.5)

TC45935101

TC45935301

46

48

10E

48DBA2-10E

12 (5.5)

TC45935101

TC45935301

46

48

15E

48DBA2-15E

12 (5.5)

TC45935101

TC45935301

46

48

20E

48DBA2-20E

12 (5.5)

TC45935101

TC45935301

46

48

25E

48DBA2-25E

12 (5.5)

TC45935101

TC45935301

46

48

30E

48DBA2-30E

12 (5.5)

TC45935101

TC45935301

2

46

48

40E

48DBA2-40E

12 (5.5)

TC45935101

TC45935301

46

48

50E

48DBA2-50E

12 (5.5)

TC45935101

TC45935301

2

46

48

65E

48DBA2-65E

12 (5.5)

TC45935101

TC45935301

46

48

80E

48DBA2-780E

12 (5.5)

TC45935101

TC45935301

46

48

100E

48DBA2-100E

12 (5.5)

TC45935101

TC45935301

2

46

48

125E

48DBA2-125E

12 (5.5)

TC45935101

TC45935301

46

48

150E

48DBA2-150E

12 (5.5)

TC45935101

TC45935301

2

46

48

200E

48DBA2-200E

12 (5.5)

TC45935101

TC45935301

2
2

2

2
2
2
2
2
2
2
2
V14-T2-36

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
DBA Type Fuses

2.5

DBA-2 Type Expulsion Fuse Units, continued
Voltage (kV)
Nominal

2

Performance Curves
Maximum

Ampere Rating

Approximate Shipping
Weight Lbs (kg)

Catalog Number

Minimum Melting

Total Clearing

69

72

0.5

72DBA2-.5

15 (6.8)

TC45935101

TC45935301

69

72

3

72DBA2-3

15 (6.8)

TC45935101

TC45935301

69

72

5E

72DBA2-5E

15 (6.8)

TC45935101

TC45935301

69

72

7E

72DBA2-7E

15 (6.8)

TC45935101

TC45935301

69

72

10E

72DBA2-10E

15 (6.8)

TC45935101

TC45935301

69

72

15E

72DBA2-15E

15 (6.8)

TC45935101

TC45935301

69

72

20E

72DBA2-20E

15 (6.8)

TC45935101

TC45935301

69

72

25E

72DBA2-25E

15 (6.8)

TC45935101

TC45935301

69

72

30E

72DBA2-30E

15 (6.8)

TC45935101

TC45935301

69

72

40E

72DBA2-40E

15 (6.8)

TC45935101

TC45935301

69

72

50E

72DBA2-50E

15 (6.8)

TC45935101

TC45935301

69

72

65E

72DBA2-65E

15 (6.8)

TC45935101

TC45935301

69

72

80E

72DBA2-780E

15 (6.8)

TC45935101

TC45935301

69

72

100E

72DBA2-100E

15 (6.8)

TC45935101

TC45935301

69

72

125E

72DBA2-125E

15 (6.8)

TC45935101

TC45935301

69

72

150E

72DBA2-150E

15 (6.8)

TC45935101

TC45935301

69

72

200E

72DBA2-200E

15 (6.8)

TC45935101

TC45935301

92

92

3

92DBA2-3

19 (8.7)

TC45935101

TC45935401

92

92

5E

92DBA2-5E

19 (8.7)

TC45935101

TC45935401

92

92

7E

92DBA2-7E

19 (8.7)

TC45935101

TC45935401

92

92

10E

92DBA2-10E

19 (8.7)

TC45935101

TC45935401

92

92

15E

92DBA2-15E

19 (8.7)

TC45935101

TC45935401

92

92

20E

92DBA2-20E

19 (8.7)

TC45935101

TC45935401

92

92

25E

92DBA2-25E

19 (8.7)

TC45935101

TC45935401

92

92

30E

92DBA2-30E

19 (8.7)

TC45935101

TC45935401

92

92

40E

92DBA2-40E

19 (8.7)

TC45935101

TC45935401

92

92

50E

92DBA2-50E

19 (8.7)

TC45935101

TC45935401

92

92

65E

92DBA2-65E

19 (8.7)

TC45935101

TC45935401

92

92

80E

92DBA2-780E

19 (8.7)

TC45935101

TC45935401

92

92

100E

92DBA2-100E

19 (8.7)

TC45935101

TC45935401

92

92

125E

92DBA2-125E

19 (8.7)

TC45935101

TC45935401

92

92

150E

92DBA2-150E

19 (8.7)

TC45935101

TC45935401

92

92

200E

92DBA2-200E

19 (8.7)

TC45935101

TC45935401

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-37

2.5
2
2
2

Expulsion Fuses
DBA Type Fuses

DBA-2 Type Expulsion Fuse Units, continued
Voltage (kV)

Performance Curves

Nominal

Maximum

Ampere Rating

Catalog Number

Approximate Shipping
Weight Lbs (kg)

115

121

3

121DBA2-3

22 (10)

Minimum Melting

Total Clearing

TC45935101

TC45935401

115

121

5E

121DBA2-5E

22 (10)

TC45935101

TC45935401

2

115

121

7E

121DBA2-7E

22 (10)

TC45935101

TC45935401

115

121

10E

121DBA2-10E

22 (10)

TC45935101

TC45935401

2

115

121

15E

121DBA2-15E

22 (10)

TC45935101

TC45935401

2

115

121

20E

121DBA2-20E

22 (10)

TC45935101

TC45935401

115

121

25E

121DBA2-25E

22 (10)

TC45935101

TC45935401

2
2
2
2

115

121

30E

121DBA2-30E

22 (10)

TC45935101

TC45935401

115

121

40E

121DBA2-40E

22 (10)

TC45935101

TC45935401

115

121

50E

121DBA2-50E

22 (10)

TC45935101

TC45935401

115

121

65E

121DBA2-65E

22 (10)

TC45935101

TC45935401

115

121

80E

121DBA2-780E

22 (10)

TC45935101

TC45935401

115

121

100E

121DBA2-100E

22 (10)

TC45935101

TC45935401

115

121

125E

121DBA2-125E

22 (10)

TC45935101

TC45935401

2

115

121

150E

121DBA2-150E

22 (10)

TC45935101

TC45935401

115

121

200E

121DBA2-200E

22 (10)

TC45935101

TC45935401

2

138

145

3

145DBA2-3

25 (11.4)

TC45935101

TC45935401

2

138

145

5E

145DBA2-5E

25 (11.4)

TC45935101

TC45935401

138

145

7E

145DBA2-7E

25 (11.4)

TC45935101

TC45935401

2
2

138

145

10E

145DBA2-10E

25 (11.4)

TC45935101

TC45935401

138

145

15E

145DBA2-15E

25 (11.4)

TC45935101

TC45935401

138

145

20E

145DBA2-20E

25 (11.4)

TC45935101

TC45935401

138

145

25E

145DBA2-25E

25 (11.4)

TC45935101

TC45935401

138

145

30E

145DBA2-30E

25 (11.4)

TC45935101

TC45935401

138

145

40E

145DBA2-40E

25 (11.4)

TC45935101

TC45935401

138

145

50E

145DBA2-50E

25 (11.4)

TC45935101

TC45935401

2

138

145

65E

145DBA2-65E

25 (11.4)

TC45935101

TC45935401

138

145

80E

145DBA2-780E

25 (11.4)

TC45935101

TC45935401

2

138

145

100E

145DBA2-100E

25 (11.4)

TC45935101

TC45935401

138

145

125E

145DBA2-125E

25 (11.4)

TC45935101

TC45935401

138

145

150E

145DBA2-150E

25 (11.4)

TC45935101

TC45935401

138

145

200E

145DBA2-200E

25 (11.4)

TC45935101

TC45935401

2
2

2
2
2
2
2
2
2
2
2
2
2

V14-T2-38

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
DBU Type Fuses

2.6

Contents

DBU Fuse Unit in Outdoor Mounting

Description

Page

DBU Type Fuses
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interruption and Protection . . . . . . . . . . . . . . . .
Testing and Performance. . . . . . . . . . . . . . . . . .
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection. . . . . . . . . . . . . . . . .
Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
2

V14-T2-40
V14-T2-41
V14-T2-43
V14-T2-43
V14-T2-44
V14-T2-44
V14-T2-45
V14-T2-50

2
2
2
2
2
2
2
2
2

DBU Type Fuses
Product Description
Introduction
Eaton’s DBU (Distribution
Boric acid fuse Unit) power
and distribution fuses are
expulsion-style fuse units
designed for both indoor and
outdoor applications. DBU
fuse units provide a low initial
cost alternative to refillable
fuses.
Conventional distribution
cutouts use a fuse link in a
fiber tube within the fuse
holder for fault interruption.
DBU fuses far exceed the
cutout in interrupting rating,
and considerably reduce the
hazards and noise produced
by the violent exhaust of
cutouts under fault
interrupting conditions. DBU
fuses employ calibrated silver
elements with a parallel strain
links, boric acid interrupting
media, and a spring and rod
mechanism, all housed inside
a sealed rigid enclosure. The
design is optimized to give a
low arc voltage and mild
exhaust during fault
interruption. DBU expulsion
fuses are available in three
voltage classes: 17 kV, 27 kV,
and 38 kV, and in three speed
variations: Standard “E”,
Slow “E”, and “K” with
amperage sizes ranging from
3A through 200A.

2

Construction
A DBU fuse comprises the
fuse unit, end fittings
(including a muffler when
installed in an indoor
mounting), and a mounting.
Principle parts of the
replaceable DBU fuse unit are
illustrated in the cross section
view of the figure on Page
V14-T2-40. The active parts
of the fuse unit are the
calibrated current responsive
silver element with a parallel
high strength strain wire,
arcing rod, boric acid cylinder,
and spring. To ensure
adequate strength to contain
the force of the arc
interruption, the assembly is
enclosed in a high strength
glass-epoxy tube with plated
copper end connections. The
use of a calibrated pure silver
element and Nichrome™
strain wire makes the DBU
less prone to premature
operation caused by vibration,
corona corrosion, or aging of
the fuse elements. It is not
susceptible to damage by
transient faults or overloads
that may approach the
minimum melt time-current
curve point.

Under normal load conditions,
a positive low resistance
sliding connection is
maintained between the
movable arcing rod and the
fixed contact at the upper end
of the fuse unit with a tulip
contact. Durable
weatherproof labels are
attached to each fuse to
provide rating and
manufacturer information.
Operation
DBU expulsion fuses use the
proven performance of boric
acid to create the de-ionizing
action needed to interrupt
fault currents. Interruption is
achieved by the action of the
arcing rod and a charged
compression spring that
elongates the arc through a
boric acid chamber when the
arcing rod is released by the
melting and arcing of the fuse
element and strain wire. The
high temperature of the arc
separates the hydrated boric

acid producing a blast of
water vapor and inert boric
anhydride. This expanding
mixture extinguishes the arc
by blasting through and deionizing it. At high levels of
fault current, the exhaust
caused by the interruption
ruptures the vent disc and
exits from the bottom of the
fuse. At lower values of fault
current, the interruption is
confined within the fuse unit,
and there is no exhaust from
the fuse. The de-ionizing
action prevents the arc from
restriking after a current zero.
DBU fuses are designed to
interrupt short-circuit currents
within 1/2 cycle at the next
current zero. The relative
details of the boric acid
cylinder and the arcing rod
and element assemblies are
tuned to limit any noise and
hazard produced by a fuse
operation at all levels of fault
current.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-39

2.6
2

Expulsion Fuses
DBU Type Fuses

DBU Sectioned View

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

When the fuse operates, the
spring forces the top of the
arcing rod to penetrate the
upper seal. On indoor
applications, this action
causes the visible blown fuse
indicator to actuate.
On outdoor installations, the
latch releases the fuse unit
allowing the ejector spring to
move the assembly outward
and swing into the vertical
down dropout position. This
dropout action provides
immediate visual indication
that the fuse has interrupted
a fault. When a fuse has
operated and the dropout
action is complete, the fuse
unit complete with end
fittings can be removed with
a switch stick. Refer to I.L.36642-E for Installation
Instructions.

Applications
DBU fuses provide effective
protection for circuits and
equipment that operate on
systems with voltage ratings up
to 34,500V. They can be used
on both electric utility and
industrial distribution systems
and are suitable for use on the
following:

2

●

2

●

2

●

●

●

●

2
2
2
2
2
2

●

Power transformers
Feeder circuits
Distribution transformers
Potential transformers
Station service transformers
Metal-enclosed switchgear
Pad mount switches

DBU fuse units are sealed and
can be used in outdoor or
indoor applications. They can be
used to directly replace
competitive equivalent units.
DBU Fuse Unit
A DBU fuse unit is comprised
of a compression spring, an
arcing rod, a calibrated

V14-T2-40

DBU fuse units have reliable
performance in compliance
with industry-standard timecurrent characteristics which
allow close coordination that
other DBU fuses, as well as
other fuses and a wide variety
of other protective devices.
DBU fuses operate promptly to
limit the stress on electrical
systems due to short-circuits.
They isolate the faulted circuit,
limiting service interruptions.
They act rapidly to take
transformers off-line,
preventing tank rupture, and
feeder circuits off-line before
damage can become
widespread. They also provide
excellent isolation for
capacitors, preventing case
failure in the event of a fault
condition.
When installed on the primary
side of substation power
transformers, DBU fuses
provide protection against
small, medium or large faults.
Regardless of the nature of the
fault, full protection is provided
even down to minimum melt
current.
DBU Details
Eaton’s DBU fuses provide
superior performance and are
applicable for distribution
system protection up to an
operational voltage of 34.5KV.
Because DBU fuses are
available in a range of current
and speed ratings, close fusing
can be achieved to maximize
protection and overall
coordination. The quality of the
DBU design and manufacturing
process ensures repeatable
accuracy and ongoing timecurrent protection.

solid boric acid liner that
assists with the interruption.
All of these components are
contained within a high
strength glass-epoxy tube
sealed with high conductivity
copper end contacts that are
compatible with industry
standard end fittings for
indoor or outdoor application.
The calibrated fuse element
determines the operational
fault response characteristics
of the fuse unit, which are
indicated on the specific
time-current characteristic
curve.
The heavy copper cylindrical
arcing rod is contained within
the boric acid liner and
performs two functions.
Under normal conditions, it
conducts the continuous
rated current of the fuse.
When the fuse element and
strain wire melt during a fault
condition, the arcing rod
draws and lengthens the arc
as it moves up through the
boric acid liner. This
movement is caused by
spring tension accelerating
the arcing rod after release by
the melted strain link.
Intense heat from the arc
separates the hydrated boric
acid producing water vapor
and inert boric anhydride that
extinguishes and de-ionizes
the arc.
On low current interruptions,
the vent diaphragm is not
ruptured, and the pressure
retained within the fuse unit
helps to extinguish the low
intensity arc. On high current
interruptions, the vent
diaphragm is ruptured and
the exhaust exits from the
bottom of the fuse.
In either case, the resulting
dielectric strength generated
in the fuse unit prevents
reignition of the arc after a
current zero.

current responsive silver
element with a parallel
mechanical strain wire that
isolates the silver element
from the spring tension, and a

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

DBU fuse units are discarded
after fault interruption, and do
not present any
environmental hazard if
discarded in a landfill.
DBU End Fittings
End fittings that are
positioned on the top and
bottom of the fuse unit and
are required to complete the
electrical connection
between the fuse unit and
mounting, can be reused if
they remain undamaged.
They are completely
interchangeable with other
comparable industry standard
end fittings.
Outdoor End Fittings
Reusable outdoor end fittings
are silver plated and made of
a cast high conductivity
copper alloy. The hookeye in
the lower end fitting allows
the fuse unit to be easily
lifted in or out of the lower
hinge contact of the
mounting. A large hookeye
on the upper fitting allows for
easy operation in pole-top
mountings with a switch
stick. The design of the upper
end fitting provides for proper
engagement in the upper
contact assembly of the
mounting. The positive
locking action of the latch
mechanism prevents
detachment from the
mounting due to shock or
vibration. The lower end
fitting has two cylindrical
posts that insert into the
lower contact assembly of
the mounting. These posts
allow the fuse to rotate into
the proper engaged position,
and suspend the fuse in the
operated, drop-out position. If
a fault occurs, the arcing rod
will pierce the seal at the
upper end of the fuse unit,
and cause the latch to
release. Once released, the
fuse will rotate down into the
drop-out position to indicate
that the fuse has operated.

Expulsion Fuses
DBU Type Fuses

Indoor End Fittings
Reusable indoor end fittings
are composed of high-impact
plastic and high conductivity
copper alloy. The visual
indicator located on the top
end fitting, provides clear
indication of a fuse unit that
has operated. The silverplated contact rod insures
positive conductivity
between the fuse unit and
the upper contact assembly
of the mounting.
The spring-biased plastic
latch hookeye actuates the
latch mechanism when
engaged into the mounting. It
readily accepts a switch stick
to insert or remove the
assembled fuse unit. A
locating pin in the upper end
fitting assembly ensures
proper alignment and
engagement with the fuse
unit. The cast bottom indoor
end fitting has a locating slot
on the inside bore that aligns
with a locating pin on the
lower section of the fuse unit
to provide proper alignment
with the mounting.
The bottom indoor end fitting
is attached to the fuse unit by
threading a muffler into the
end fitting, and so clamping
the fitting to the fuse unit.
Projections on the bottom of
the muffler allow sufficient
torque to be applied to seal
the muffler to the fuse unit.
The lower ferrule of the fuse
unit directly contacts the
lower contacts of the
mounting. The muffler
absorbs noise and
contamination from arcing
products to prevent
contamination of indoor
equipment. The muffler is
constructed of a plated steel
housing, containing copper
mesh screening. This copper
mesh acts to absorb and
contain the noise, and
de-ionize exhaust materials
of the fuse during a fault
interruption. De-ionizing the
exhaust gases prevents
accidental flashover from
phase-to-phase or phase-toground by limiting foreign
airborne particles and gases.

Mountings and Live Parts
Eaton offers a full line of
outdoor mountings  and
indoor loadbreak and nonloadbreak mountings and live
parts for the DBU fuse family.
Mountings are available in
17 kV, 27 kV, and 38 kV class
designs, and these
mountings will readily
accommodate DBU fuses
and other equivalent industry
standard fuses. DBU
mountings have a rated
maximum continuous current
of 200A, with a rated
maximum interrupting
current up to 14 kA. The
following lists the LIWV rated
lightning impulse withstand
voltage rating of each voltage
class (BIL):
●
●
●

17 kV–95 kV
27 kV–125 kV
38 kV–150 kV

Indoor loadbreak units have a
maximum three-time fault
close ASYM of 22,400A rms.
Refer to the catalog number
section for exact ratings per
unit. Indoor mountings are
constructed with rigid steel
bases that are powder coated
and baked. Bases are
supplied with preformed
mounting holes for easy
installation.
Insulators are molded of high
strength epoxy material for
superior insulating
characteristics. Live parts are
rigidly secured to the
insulators with standard
mounting hardware.
Both left and right side cable
terminations are available for
indoor mountings for proper
installation spacing. All bus
connections are plated
copper for improved
conductivity and endurance.
All loadbreak units have a
three-time fault close rating.
These fuse mountings can
withstand a fuse assembly
being closed into a fault of
the magnitude specified
three times when closed
briskly without hesitation, and
remain operable and able to
carry and interrupt the

continuous current. All live
parts are constructed of
silver-plated copper to ensure
maximum and sustained
conductivity.
Live parts can be purchased
as separate kits without
mountings.

Interruption and Protection
DBU fuses provide effective
protection for circuits and
equipment operating on
voltages from 2400V through
34,500V. They are designed
to carry their rated
continuous current without
exceeding the temperature
rise limits specified in IEEE
and ANSl standards.
Under normal conditions, the
temperature of the fusible
element is well below the
melting temperature and
does not melt.
Under overload conditions,
when the current is above
any allowable overload
condition for an extended
period of time, but below the
minimum level of current
indicated on the total clearing
time-current curve, the
element temperature is
below the melting
temperature, but the heat
generated within the fuse
unit may be sufficient to
cause permanent degradation
of the structure of the fuse
unit, sufficient to interfere
with the ability of the fuse
unit to perform as designed.
Under fault conditions, when
a fault occurs that is large
enough to melt the fuse
element, an arc is initiated
and elongated by the spring,
pulling the arcing rod up into
the boric acid interrupting
media. The heat produced
separates the material of the
boric acid liner producing
water vapor and boric
anhydride that de-ionize the
arc. At low fault current levels
the pressure in the arcing
chamber along with the
elongation of the arc gives
sufficient dielectric strength
to extinguish the arc at a
natural current zero without

2.6

bursting the pressure
diaphragm. At higher fault
current levels, the byproducts extinguish the arc at
a natural current zero by
bursting the pressure
diaphragm and forcing the arc
products out of the bottom of
the fuse unit. When installed
indoors, the exhaust and
noise produced during the
interruption process are
limited by the muffler
attached to the lower end
fitting. When installed
outdoors, the arc products
are exhausted.
During the interrupting
process, current continues to
flow in the circuit and in the
fuse until a current zero is
reached. When the arc is
extinguished at current zero,
the voltage across the fuse
will attempt to re-ignite the
arc. The voltage across the
fuse immediately after the
voltage zero is the sum of the
circuit power frequency
recovery voltage and a high
frequency oscillatory voltage
controlled by the circuit
inductance and stray
capacitance. This high
frequency oscillatory voltage
is called the Transient
Recovery Voltage (TRV). After
the fuse has interrupted a
fault current at a natural
circuit current zero, the
dielectric gap must withstand
this combined voltage to
prevent re-ignition of the arc
for a successful interruption
to occur.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

The rated maximum voltage
of a DBU fuse is the highest
rms voltage at which the fuse
is designed to operate. The
dielectric withstand level
corresponds to insulation
levels of power class and
distribution class equipment,
as DBU fuses can be used in
either environment.
Maximum voltage ratings for
DBU fuses are: 17 kV, 27 kV,
and 38 kV.

2

Note
 Outdoor mountings available for 17 kV
and 27 kV.

2

2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-41

2.6
2
2
2
2
2
2
2
2
2
2
2
2

Expulsion Fuses
DBU Type Fuses

Fuses should never be
applied where the available
fault current exceeds the
rated maximum interrupting
current of the fuse, or the
maximum value of the power
frequency system voltage
exceeds the rated maximum
voltage of the fuse.
The rated maximum
interrupting current values for
DBU fuses are listed on Page
V14-T2-44.
The continuous current rating
of a DBU power fuse should
equal or exceed the
maximum load current where
the fuse is applied.
DBU fuse units are available
with continuous current
ratings up to 200A and are
designated as either E- or
K-rated. These designations
are defined in ANSI/IEEE Std.
C37.42™ and C37.46™.

Coordination Consideration
Coordination considerations
must be made to help
determine what type of fuse
is applied. The DBU power
fuse interrupts at a natural
current zero in the current
wave and allows a minimum
of a half cycle of fault current
to flow before the fault is
cleared. The time-current
characteristics associated
with a DBU has a rather
gradual slope making it easier
to coordinate with
downstream equipment. In
addition, the DBU is ideal for
higher voltage (up to 38 kV)
and high current applications
(through 200A). It is
important to examine the
minimum melting and total
clearing time-current
characteristics of this
particular fuse.

The melting time is the time
in seconds required to melt
the fuse element. This curve
indicates when or even if the
element of the fuse will melt
for different symmetrical
current magnitudes.
The total clearing time is the
total amount of time it takes
to clear a fault once the
element has melted. The
total clearing time is really the
sum of the melting time and
the time the fuse arcs during
the clearing process. The
DBU power fuse is offered in
three configurations for use
with high currents: “E”
(Standard), “K” (Fast) and
“SE” (Slow). The curves for
the SE are less inverse and
allow for more of a time delay
at high currents.

2
2
2

DBU Power Fuse Short-Circuit Interrupting Ratings

2

Nominal kV

2

DBU

System

Interrupting Amperes
Symmetrical
Based on X/R = 16

17

7.2

14,000

Interrupting mVA
(Three-Phase Symmetrical)
Asymmetrical
22,400

Where X/R = 16
175

2

4.8/8.32Y

200

7.2/12.47Y

300

2

7.62/13.2Y

320

13.8

335

14.4

350

2
2

16.5
27

400

7.2/12.47Y

12,500

20,000

270

2

7.62/13.2Y

285

13.8

300

2

14.4

310

16.5

365

23.0

500

2
2
2

38

2
2
2
2

14.4/24.9Y

540

20/34.5Y 

—

23.0

10,000

16,000

—

14.4/24.9Y

—

27.6

475

20/34.5Y

600

34.5

600

Note
 Applies to 23 kV single-insulator style only, for the protection of single-phase-to-neutral circuits (line or transformers) and three-phase
transformers or banks with solidly grounded neutral connections.

V14-T2-42

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Finally, low currents, usually
referred to as overload
currents, must also be
considered. The DBU and
other expulsion fuses have a
rather low thermal capacity
and cannot carry overloads of
the same magnitude and
duration as motors and
transformers of equal
continuous currents. For this
reason, the fuse must be
sized with the full load
current in mind. This
consideration should be
made so the fuse does not
blow on otherwise
acceptable overloads and
inrush conditions.
The Eaton DBU family of
power fuses is broad and
comprehensive. Refer to the
table below to review the
ratings available for most
application requirements. The
final selection process for
new applications will include
the fuse unit, end fittings, and
a mounting.

Expulsion Fuses
DBU Type Fuses

Testing and Performance
●
●
●

Standards
Testing
Quality standards

Eaton does not compromise
when performance, quality
and safety are involved.
Exacting standards have been
established relative to the
design, testing and
application of expulsion type
power fuses. Compliance
with these standards ensures
the best selection and
performance. DBU type
power fuses are designed
and tested to applicable
portions of ANSl standards as
well as other industry
standards. The ANSl
standards are Consensus
Standards jointly formulated
by IEEE and NEMA.
IEEE (Institute of Electrical
and Electronic Engineers) is
an objective technical
organization made up of
manufacturers, users and
other general interest parties.
NEMA (National Electrical
Manufacturers Association) is
an electrical equipment
manufacturer only
organization with members
like Eaton. ANSl (American
National Standards Institute)
is a nonprofit, privately
funded membership
organization that coordinates
the development of U.S.
voluntary national standards.
It is also the U.S. member
body to the non-treaty
international standards

bodies, such as International
Organization for
Standardization ([SO) and the
International Electrotechnical
Commission (IEC).
The specific standards
associated with DBU power
fuses are:
●

●

●

●

●

ANSl C37.40–Service
Conditions and Definitions
ANSl C37.41–Power Fuse
Design and Testing
ANSl C37.42–Distribution
Fuse Ratings and
Specification
ANSl C37.46–Power Fuse
Ratings and Specifications
ANSI ~37.48–Power Fuse
Application, Operation and
Maintenance

Testing
DBU power fuse unit design
testing was performed on
standard production fuses,
holders, mountings and
accessories. Demanding
tests were performed by
Eaton Technical Support and
also at recognized
independent power testing
laboratories. Thermal and
interrupting testing was
conducted at 17, 27, and
38 kV levels. The entire
series of tests was
conducted in a specific
sequence as stipulated by
governing standards without
any maintenance being
performed.

2.6

Quality
Every effort is made to
ensure the delivery of quality
fuse units and customer
satisfaction. All Eaton fuses
are completely inspected at
each manufacturing stage. In
addition to ongoing quality
control inspections, testing is
performed prior to shipment.
A Micro-Ohm Resistance
Test is performed on each
fuse to assure proper
element construction,
alignment and tightness of
electrical connections.
Construction integrity testing
is also performed on every
unit.

2
2
2
2
2
2
2
2
2

Each DBU fuse unit is
checked to ensure that all
items are supplied in keeping
with manufacturing drawings.
Individual fuses are packed in
a plastic bag and then put into
individual cartons. In addition,
fuses are overpacked in a
shipping carton to prevent
shipping damage. Finally,
mountings are packaged in
heavy cardboard containers
with reinforced wooden
bases.

2
2
2
2
2
2

Installation

2

Installation instructions are
contained within I.L. 36-642.

2
2
2
2

All test results are verified by
laboratory tabulations and
oscillogram plots.

2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-43

2.6

Expulsion Fuses
DBU Type Fuses

2

Catalog Number Selection

2

DBU Fuse Units

DBU 17 100 E

2
2

Type
DBU

2
2

Voltage Rating
17 = 17.1 kV
27 = 27 kV
38 = 38 kV

2
2
2
2

Speed
E
K
SE

Ampere
Rating
3
30
5
40
6
50
7
65
8
80
10
100
12
125
13
140
15
150
20
175
25
200

DBU Mounting Catalog Numbers

2

DBU 17 - G DM - L

2
Type
DBU

2
2

Voltage Rating
17 = 17.1 kV
27 = 27 kV
38 = 38 kV

Insulator
G = Glass polyester
P = Porcelain

2
2

DL
DM
EFID
EFOD
MFLR
NL
NLP
NM
NMP

Hardware
= Disconnect live parts
= Disconnect mounting
= Indoor end fittings
= Outdoor end fittings
= Muffler
= Non-disconnect live parts
= Non-disconnect live parts (SS)
= Non-disconnect mounting
= Non-disconnect mounting (SS)

2
2
2
2
2
2

Interrupting Ratings
DBU Fuse Interrupting Ratings
Fuse Unit
Maximum Rated
Voltage Rating kV

Maximum System
Voltage kV

Indoor with
Outdoor Vented rms Muffler rms
Symmetrical kA
Symmetrical kA

17.1

17.1

14.0

14.0

27

27

12.5

12.5

38

38

10.0

8.5

2
2
2
2
2
2
2
2
V14-T2-44

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Connection Side
L = Left hand
R = Right hand

Expulsion Fuses
DBU Type Fuses

2.6

Product Selection

2

DBU17 Type Standard E Speed Expulsion Fuse Units
Voltage (kV)
Nominal

2

Performance Curves
Maximum

Ampere Rating

Approximate Shipping
Weight Lbs (kg)

Catalog Number

Minimum Melting

Total Clearing

14.4

17.1

5

DBU17-5E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

7

DBU17-7E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

10

DBU17-10E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

13

DBU17-13E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

15

DBU17-15E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

20

DBU17-20E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

25

DBU17-25E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

30

DBU17-30E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

40

DBU17-40E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

50

DBU17-50E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

65

DBU17-65E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

80

DBU17-80E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

100

DBU17-100E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

125

DBU17-125E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

150

DBU17-150E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

175

DBU17-175E

2.1 (1.0)

TC66702701

TC66703001

14.4

17.1

200

DBU17-200E

2.1 (1.0)

TC66702701

TC66703001

2
2
2
2
2
2
2
2
2
2
2
2
2

DBU17 Type K Speed Expulsion Fuse Units
Voltage (kV)
Nominal

Performance Curves
Maximum

Ampere Rating

Approximate Shipping
Weight Lbs (kg)

Catalog Number

Minimum Melting

Total Clearing

14.4

17.1

3

DBU17-3K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

6

DBU17-6K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

8

DBU1780K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

10

DBU17-10K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

12

DBU17-12K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

15

DBU17-15K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

20

DBU17-20K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

25

DBU17-25K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

30

DBU17-30K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

40

DBU17-40K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

50

DBU17-50K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

65

DBU17-65K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

80

DBU17-80K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

100

DBU17-100K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

140

DBU17-140K

2.1 (1.0)

TC66702801

TC66703101

14.4

17.1

200

DBU17-200K

2.1 (1.0)

TC66702801

TC66703101

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-45

2.6
2
2
2
2
2
2

Expulsion Fuses
DBU Type Fuses

DBU17 Type Slow E Speed Expulsion Fuse Units
Voltage (kV)

Performance Curves

Nominal

Maximum

Ampere Rating

Catalog Number

Approximate Shipping
Weight Lbs (kg)

Minimum Melting

Total Clearing

14.4

17.1

15

DBU17-15SE

2.1 (1.0)

TC66702601

TC66702901

14.4

17.1

20

DBU17-20SE

2.1 (1.0)

TC66702601

TC66702901

14.4

17.1

25

DBU17-25SE

2.1 (1.0)

TC66702601

TC66702901

14.4

17.1

30

DBU17-30SE

2.1 (1.0)

TC66702601

TC66702901

14.4

17.1

40

DBU17-40SE

2.1 (1.0)

TC66702601

TC66702901

14.4

17.1

50

DBU17-50SE

2.1 (1.0)

TC66702601

TC66702901

14.4

17.1

65

DBU17-65SE

2.1 (1.0)

TC66702601

TC66702901

2

14.4

17.1

80

DBU17-80SE

2.1 (1.0)

TC66702601

TC66702901

2

14.4

17.1

100

DBU17-100SE

2.1 (1.0)

TC66702601

TC66702901

14.4

17.1

125

DBU17-125SE

2.1 (1.0)

TC66702601

TC66702901

2
2

14.4

17.1

150

DBU17-150SE

2.1 (1.0)

TC66702601

TC66702901

14.4

17.1

175

DBU17-175SE

2.1 (1.0)

TC66702601

TC66702901

14.4

17.1

200

DBU17-200SE

2.1 (1.0)

TC66702601

TC66702901

2
DBU27 Type Standard E Speed Expulsion Fuse Units

2
2
2
2
2
2
2

Voltage (kV)
Nominal

Performance Curves
Maximum

Ampere Rating

Catalog Number

Approximate Shipping
Weight Lbs (kg)

Minimum Melting

Total Clearing

23

27

5

DBU27-5E

2.5 (1.15)

TC66702701

TC66703901

23

27

7

DBU27-7E

2.5 (1.15)

TC66702701

TC66703901

23

27

10

DBU27-10E

2.5 (1.15)

TC66702701

TC66703901

23

27

13

DBU27-13E

2.5 (1.15)

TC66702701

TC66703901

23

27

15

DBU27-15E

2.5 (1.15)

TC66702701

TC66703901

23

27

20

DBU27-20E

2.5 (1.15)

TC66702701

TC66703901

23

27

25

DBU27-25E

2.5 (1.15)

TC66702701

TC66703901

23

27

30

DBU27-30E

2.5 (1.15)

TC66702701

TC66703901

23

27

40

DBU27-40E

2.5 (1.15)

TC66702701

TC66703901

23

27

50

DBU27-50E

2.5 (1.15)

TC66702701

TC66703901

23

27

65

DBU27-65E

2.5 (1.15)

TC66702701

TC66703901

23

27

80

DBU27-80E

2.5 (1.15)

TC66702701

TC66703901

2

23

27

100

DBU27-100E

2.5 (1.15)

TC66702701

TC66703901

23

27

125

DBU27-125E

2.5 (1.15)

TC66702701

TC66703901

2

23

27

150

DBU27-150E

2.5 (1.15)

TC66702701

TC66703901

23

27

175

DBU27-175E

2.5 (1.15)

TC66702701

TC66703901

23

27

200

DBU27-200E

2.5 (1.15)

TC66702701

TC66703901

2
2

2
2
2
2
2
2
2
2

V14-T2-46

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
DBU Type Fuses

2.6

DBU27 Type K Speed Expulsion Fuse Units
Voltage (kV)
Nominal

2

Performance Curves
Maximum

Ampere Rating

Approximate Shipping
Weight Lbs (kg)

Catalog Number

Minimum Melting

Total Clearing

23

27

3

DBU27-3K

2.5 (1.15)

TC66702801

TC66704001

23

27

6

DBU27-6K

2.5 (1.15)

TC66702801

TC66704001

23

27

8

DBU27-8K

2.5 (1.15)

TC66702801

TC66704001

23

27

10

DBU27-10K

2.5 (1.15)

TC66702801

TC66704001

23

27

12

DBU27-12K

2.5 (1.15)

TC66702801

TC66704001

23

27

15

DBU27-15K

2.5 (1.15)

TC66702801

TC66704001

23

27

20

DBU27-20K

2.5 (1.15)

TC66702801

TC66704001

23

27

25

DBU27-25K

2.5 (1.15)

TC66702801

TC66704001

23

27

30

DBU27-30K

2.5 (1.15)

TC66702801

TC66704001

23

27

40

DBU27-40K

2.5 (1.15)

TC66702801

TC66704001

23

27

50

DBU27-50K

2.5 (1.15)

TC66702801

TC66704001

23

27

65

DBU27-65K

2.5 (1.15)

TC66702801

TC66704001

23

27

80

DBU27-80K

2.5 (1.15)

TC66702801

TC66704001

23

27

100

DBU27-100K

2.5 (1.15)

TC66702801

TC66704001

23

27

140

DBU27-140K

2.5 (1.15)

TC66702801

TC66704001

23

27

200

DBU27-200K

2.5 (1.15)

TC66702801

TC66704001

2
2
2
2
2
2
2
2
2
2
2
2

DBU27 Type Slow E Speed Expulsion Fuse Units
Voltage (kV)

2

Performance Curves

Nominal

Maximum

Ampere Rating

Catalog Number

Approximate Shipping
Weight Lbs (kg)

Minimum Melting

Total Clearing

23

27

15

DBU27-15SE

2.5 (1.15)

TC66702601

TC66703801

23

27

20

DBU27-20SE

2.5 (1.15)

TC66702601

TC66703801

23

27

25

DBU27-25SE

2.5 (1.15)

TC66702601

TC66703801

23

27

30

DBU27-30SE

2.5 (1.15)

TC66702601

TC66703801

23

27

40

DBU27-40SE

2.5 (1.15)

TC66702601

TC66703801

23

27

50

DBU27-50SE

2.5 (1.15)

TC66702601

TC66703801

23

27

65

DBU27-65SE

2.5 (1.15)

TC66702601

TC66703801

23

27

80

DBU27-80SE

2.5 (1.15)

TC66702601

TC66703801

23

27

100

DBU27-100SE

2.5 (1.15)

TC66702601

TC66703801

23

27

125

DBU27-125SE

2.5 (1.15)

TC66702601

TC66703801

23

27

150

DBU27-150SE

2.5 (1.15)

TC66702601

TC66703801

23

27

175

DBU27-175SE

2.5 (1.15)

TC66702601

TC66703801

23

27

200

DBU27-200SE

2.5 (1.15)

TC66702601

TC66703801

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-47

2.6
2
2
2
2
2
2

Expulsion Fuses
DBU Type Fuses

DBU38 Type Standard E Speed Expulsion Fuse Units
Voltage (kV)

Performance Curves

Nominal

Maximum

Ampere Rating

Catalog Number

Approximate Shipping
Weight Lbs (kg)

Minimum Melting

Total Clearing

34.5

38

5

DBU38-5E

2.8 (1.3)

TC66702701

TC66703901

34.5

38

7

DBU38-7E

2.8 (1.3)

TC66702701

TC66703901

34.5

38

10

DBU38-10E

2.8 (1.3)

TC66702701

TC66703901

34.5

38

13

DBU38-13E

2.8 (1.3)

TC66702701

TC66703901

34.5

38

15

DBU38-15E

2.8 (1.3)

TC66702701

TC66703901

34.5

38

20

DBU38-20E

2.8 (1.3)

TC66702701

TC66703901

34.5

38

25

DBU38-25E

2.8 (1.3)

TC66702701

TC66703901

2

34.5

38

30

DBU38-30E

2.8 (1.3)

TC66702701

TC66703901

2

34.5

38

40

DBU38-40E

2.8 (1.3)

TC66702701

TC66703901

34.5

38

50

DBU38-50E

2.8 (1.3)

TC66702701

TC66703901

2
2
2
2

34.5

38

65

DBU38-65E

2.8 (1.3)

TC66702701

TC66703901

34.5

38

80

DBU38-80E

2.8 (1.3)

TC66702701

TC66703901

34.5

38

100

DBU38-100E

2.8 (1.3)

TC66702701

TC66703901

34.5

38

125

DBU38-125E

2.8 (1.3)

TC66702701

TC66703901

34.5

38

150

DBU38-150E

2.8 (1.3)

TC66702701

TC66703901

34.5

38

175

DBU38-175E

2.8 (1.3)

TC66702701

TC66703901

34.5

38

200

DBU38-200E

2.8 (1.3)

TC66702701

TC66703901

Catalog Number

Approximate Shipping
Weight Lbs (kg)

2
2

DBU38 Type K Speed Expulsion Fuse Units
Voltage (kV)

2
2
2
2
2
2
2
2
2
2
2

Nominal

Performance Curves
Maximum

Ampere Rating

Minimum Melting

Total Clearing

34.5

38

3

DBU38-3K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

6

DBU38-6K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

8

DBU38-8K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

10

DBU38-10K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

12

DBU38-12K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

15

DBU38-15K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

20

DBU38-20K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

25

DBU38-25K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

30

DBU38-30K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

40

DBU38-40K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

50

DBU38-50K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

65

DBU38-65K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

80

DBU38-80K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

100

DBU38-100K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

140

DBU38-140K

2.8 (1.3)

TC66702801

TC66704001

34.5

38

200

DBU38-200K

2.8 (1.3)

TC66702801

TC66704001

2
2
2
2
2
V14-T2-48

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
DBU Type Fuses

2.6

DBU38 Type Slow E Expulsion Fuse Units
Voltage (kV)

2

Performance Curves

Nominal

Maximum

Ampere Rating

Approximate Shipping
Weight Lbs (kg)

Catalog Number

Minimum Melting

Total Clearing

34.5

38

15

DBU38-15SE

2.8 (1.3)

TC66702601

TC66703801

34.5

38

20

DBU38-20SE

2.8 (1.3)

TC66702601

TC66703801

34.5

38

25

DBU38-25SE

2.8 (1.3)

TC66702601

TC66703801

34.5

38

30

DBU38-30SE

2.8 (1.3)

TC66702601

TC66703801

34.5

38

40

DBU38-40SE

2.8 (1.3)

TC66702601

TC66703801

34.5

38

50

DBU38-50SE

2.8 (1.3)

TC66702601

TC66703801

34.5

38

65

DBU38-65SE

2.8 (1.3)

TC66702601

TC66703801

34.5

38

80

DBU38-80SE

2.8 (1.3)

TC66702601

TC66703801

34.5

38

100

DBU38-100SE

2.8 (1.3)

TC66702601

TC66703801

34.5

38

125

DBU38-125SE

2.8 (1.3)

TC66702601

TC66703801

34.5

38

150

DBU38-150SE

2.8 (1.3)

TC66702601

TC66703801

34.5

38

175

DBU38-175SE

2.8 (1.3)

TC66702601

TC66703801

34.5

38

200

DBU38-200SE

2.8 (1.3)

TC66702601

TC66703801

2
2
2
2
2
2
2
2
2
2

DBU Type Fuse Mountings and Accessories Indoor Applications
Non-Loadbreak
Voltage (kV)

2

Loadbreak

Mountings

Live Parts

Mountings

Live Parts

End Fittings

Nominal

Ampere
Maximum Rating

Catalog
Number

Catalog
Number

Catalog
Number

Catalog
Number

Catalog
Number

Muffler
Catalog
Number

Connection

14.4

17.1

3–200

DBU17-GNM-L

DBU17-NL-L

DBU17-GDM-L DBU17-DL-L

DBU-EFID

DBU-MFLR

Left hand connections

14.4

17.1

3–200

DBU17-GNM-R

DBU17-NL-R

DBU17-GDM-R DBU17-DL-R

DBU-EFID

DBU-MFLR

Right hand connections

14.4

17.1

3–200

DBU17-GNMP-L DBU17-NLP-L

—

—

DBU-EFID

DBU-MFLR

Left hand connections stainless steel hardware

—

2
2
2

14.4

17.1

3–200

DBU17-GNMP-R DBU17-NLP-R

—

DBU-EFID

DBU-MFLR

Right hand connections stainless steel hardware

23

27

3–200

DBU27-GNM-L

DBU27-NL-L

DBU27-GDM-L DBU27-DL-L

DBU-EFID

DBU-MFLR

Left hand connections

23

27

3–200

DBU27-GNM-R

DBU27-NL-R

DBU27-GDM-R DBU27-DL-R

DBU-EFID

DBU-MFLR

Right hand connections

23

27

3–200

DBU27-GNMP-L DBU27-NLP-L

—

—

DBU-EFID

DBU-MFLR

Left hand connections stainless steel hardware

23

27

3–200

DBU27-GNMP-R DBU27-NLP-R

—

—

DBU-EFID

DBU-MFLR

Right hand connections stainless steel hardware

34.5

38

3–200

DBU38-GNM-L

DBU38-NL-L

—

—

DBU-EFID

DBU-MFLR

Left hand connections

34.5

38

3–200

DBU38-GNM-R

DBU38-NL-R

—

—

DBU-EFID

DBU-MFLR

Right hand connections

2
2
2

34.5

38

3–200

DBU38-GNMP-L DBU38-NLP-L

—

—

DBU-EFID

DBU-MFLR

Left hand connections stainless steel hardware

34.5

38

3 –200

DBU38-GNMP-R DBU38-NLP-R

—

—

DBU-EFID

DBU-MFLR

Right hand connections stainless steel hardware

2
2
2

DBU Type Fuse Mountings and Accessories
Outdoor Applications
Voltage (kV)

2

2

Non-Loadbreak
Mountings

End Fittings

Nominal

Ampere
Maximum Rating

Catalog
Number

Catalog
Number

14.4

17.1

3–200

DBU17-DM

DBU-EFOD

23

27

3–200

DBU27-DM

DBU-EFOD

2
2
2
2
2
2
2
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-49

2.6
2
2

Expulsion Fuses
DBU Type Fuses

Dimensions
Dimensions are in Inches (mm)
Non-Loadbreak Mounting

2

D

2

1.00 (25.4)
0.50 (12.7)
0.75 (19.1)

0.50 (12.7)
E
F

0.56 (14.2) Dia.

K

2
2
B

2
Side View

2
2

4.25 (108.0)
Front View
(Fuse removed)

2
2

Dimensions
B
D

kV Max.

Catalog
Number 

kv BIL

2

17

DBU17-GNM

95

18.00 16.87 12.12 8.81
2.25
(457.2) (428.0) (307.9) (223.8) (57.2)

2

27

DBU27-GNM

125

22.25 19.63 14.87 11.56 2.25
(565.2) (498.6) (377.7) (293.6) (57.2)

2

38

DBU38-GNM

150

28.25 21.33 16.58 13.28 2.25
(717.6) (541.8) (421.1) (337.3) (57.2)

2
2
2

F

K

Loadbreak Mounting

2
2

E

6.50 (165.1)
5.50 (139.7)

0.50
(12.7)

3.00 (76.2)
0.75
(19.1)

2.03
(51.6)

0.50 x 0.75
(12.7 x 19.1)
Mtg. Slots
(Four)

C
D

1.50 (38.1)
K

E
F

2.03 (51.6)

0.56
(14.2)
Dia.
B A

2

43°

B

G

2
L

2

Mounting Base Detail

2
2

Dimensions
A
B

C

D

E

F

G

H

J

K

L

M

95

22.50
(571.5)

18.44
(468.4)

30.50
(774.7)

19.25
(489.0)

14.25
(362.0)

9.25
(235.0)

18.44
(468.4)

9.44
(240.0)

11.50
(292.1)

3.0
(76.2)

9.50
(241.3)

3.75
(95.3)

125

26.75
(679.5)

22.69
(576.3)

34.63
(879.6)

21.38
(543.1)

16.75
(425.5)

11.56
(293.6)

22.69
(576.3)

11.75
(298.5)

13.50
(343.0)

3.0
(76.2)

9.50
(241.3)

3.75
(95.3)

kV Max.

Catalog
Number

kv BIL

17

DBU17-GDML 

2
2

H
J
Side View

Front View
(Fuse removed)

2
2

1.88 (47.8)

3.50 (88.9)

2

M

DBU17-GDMR 
27

DBU27-GDML 
DBU27-GDMR 

Notes
 Bus for cable termination on right side of mounting.
 Bus for cable termination on left side of mounting.

2
V14-T2-50

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

2.6

Expulsion Fuses
DBU Type Fuses

Dimensions are in Inches (mm)
Indoor DBU Fuse Fittings
0.94
(24.0)

2

Outdoor DBU Fuse Fittings
0.94
(24.0)

0.72 (18.3) Ref.

2

0.72 (18.3) Ref.

2
1.24
(31.6)
Dia.

2

1.24
(31.6)
Dia.

2

A

2

C
B Ref.

B

A

2
2
2
2
2
2

kV Max.

Fuse Unit Fittings
A

B

C

kV Max.

Fuse Unit Fittings
A

B

17

19.08 (484.6)

27.19 (538.2)

28.82 (732.0)

17

19.08 (484.6)

19.41 (493.0)

27

22.58 (573.5)

30.69 (779.5)

32.32 (821.0)

27

22.58 (573.5)

22.91 (581.9)

38

28.76 (730.5)

36.87 (936.5)

38.50 (978.0)

38

28.76 (730.5)

28.09 (713.5)

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-51

2.7
2

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

Contents

RBA Fuses

Description

2

Page

RBA/RDB Type Fuses (Including Superseded BA Fuses)
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V14-T2-52
Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . .
V14-T2-53
Operation and Features . . . . . . . . . . . . . . . . . .
V14-T2-53
Catalog Number Selection . . . . . . . . . . . . . . . .
V14-T2-58
Interrupting Ratings . . . . . . . . . . . . . . . . . . . . .
V14-T2-59
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
V14-T2-60
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V14-T2-68

2
2
2
2
2
2
2
2
2

RBA/RDB Type Fuses (Including Superseded BA Fuses)

2

Product Description

2
2
2
2
2
2
2

BA Fuses
Westinghouse Electric
Company introduced the BA
range of DE-ION boric acid
refillable fuses in the 1930s,
and BA refill units have been
in continuous use and
production since then. Eaton
still manufactures BA refill
units for use in existing fuse
holders and installations.
However, the manufacture of
most BA fuse holders and all
BA mountings has been
discontinued.

2
2
2
2
2
2
2
2
2
2

RBA and RDB Fuses
In 1969, Westinghouse
Electric Company introduced
the redesigned and improved
RBA (indoor with exhaust
control device—filter or
condenser) and RDB (vented
outdoor dropout) ranges of
boric acid DE-ION fuses to
replace the BA range of fuses
Eaton’s RBA (Refillable Boric
Acid) and RDB (Refillable
Dropout Boric acid) power
fuses are expulsion type
power fuses designed for
indoor or weatherproof
enclosure (RBA) or outdoor
vented (RDB) applications.
RBA/RDB fuses are
renewable (refillable) as the
descriptions above state. The
whole fuse unit is not
discarded after a fault
interruption. Usually, only one
piece of the fuse, the refill
unit, needs to be replaced
after an interruption and for
this reason, RBA/RDB fuses
provide an economical
approach to the protection of
power circuits rated up to a
maximum of 38 kV. They are
especially well suited for
large industrial load fusing
needs.

An RBA/RDB fuse is basically
a vented electromechanical
device which is applicable to
many different power
applications. RBA/RDB power
fuses are particularly
effective for higher
operational voltage and
higher continuous current
applications. RBA/RDB
expulsion type fuses do not
limit the magnitude of the
fault current during operation.
They limit the duration of the
fault in the electrical system.
RBA/RDB expulsion fuses are
available in a wide range of
ratings to simplify the
selection process. They offer
continuous current ratings of
0.5 through 720 amperes, at
maximum voltages of 8.3
through 38 kV and with
symmetrical interrupting
ratings up to 37,500
amperes. RBA and RBB
fuses both use replaceable
RBA refill units, which are
available with both standard
speed or time lag
characteristics, that when
combined with the wide
range of ratings, allow
maximization of both
coordination and protection.

2
V14-T2-52

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

RBA power fuses can be
used with either disconnect
or non-disconnect mounting,
so matching these fuses into
the equipment type and
layout is a simplified process.
Thus RBA fuses are easy to
install and maintain. RDB
fuses are only available for
use in outdoor dropout style
mountings.
RBA power fuses have a long
and enviable reputation for
outstanding protection and
reliability, broad selection
possibilities, ease of
installation and economy over
time.

Installation
See Publication No.
IL.36-65A-1C for installation
instructions.

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses

Applications
In general, an electrical
power system consists of
three major parts: generation,
transmission and distribution.
The power distribution area
offers an especially
significant potential for RBA
and RDB power fuse
applications. This power
distribution system potential
could be with the utility, an
industrial or commercial user,
or the manufacturer of
electrical equipment.
Since the RBA/RDB power
fuse is refillable (renewable),
it is economical for use in a
variety of distribution system
applications. Primarily, the
RBA/RDB is designed for use
on:
●

●
●
●

Load interrupter
switchgear;
Power transformers;
High voltage capacitors;
Pad mounted transformers

RBA fuses can be installed in
indoor metalclad or metal
enclosed load interrupter
switchgear, or fuse cabinets
for both indoor and outdoor
use. RDB fuses are intended
for outdoor use, but
protecting the same types of
loads as RBA fuses.

A common application for
RBA power fuses is in the
primary circuit of a power
transformer. In this
application, fuses must
isolate the transformer circuit
from the upstream supply
when a fault occurs in or
beyond the transformer, but
must not operate on
transformer inrush.

Operation and Features
A renewable (refillable) boric
acid expulsion type fuse
comprises the following
major components:
●

RBA fuses can also be used
to protect capacitor banks.
Capacitors require protection
from fault currents which
could cause a capacitor to
rupture.
Selection of the fuse type is
dependent on many factors,
including: user or supplier
preference, cost and
system coordination. If the
required voltage and
continuous current ratings
are high and downstream
coordination is critical, RBA
power fuses can provide
very effective protection.
See Page V14-T2-20 for
more information on
expulsion fuse application.

2.7

●

●

●

A replaceable refill unit,
comprising the current
responsive element and
the arc de-ionizing and
extinguishing boric acid
sold filler material, all
contained within a high
strength glass epoxy tube
and with end connections
for interfacing with the
fuse holder. This is the part
of the fuse which is
discarded after a fuse
interruption
A reusable fuse holder. The
fuse holder comprises a
high strength glass epoxy
tube and cast high
conductivity end
connections to interface
the fuse holder with the
internal refill unit and the
external fuse mounting.
The fuse holder assembly
also includes the spring
and shunt assembly which
is pre-loaded when a fuse
holder is charged with a
refill unit
For indoor applications only
(RBA fuses only), a
reusable exhaust control
device, (condenser,
discharge filter, or high
capacity discharge filter)
which de-ionizes and
absorbs all or part of the
“expulsion exhaust” from
the fuse during operation
A reusable mounting to
interface the loaded fuse
holder assembly into the
protected circuit. The
mounting comprises the
live parts, a pair of
assembles that interface
with and securely support
the fuse holder, and
provide suitable
connection points for the
external circuit. Below the
live parts are insulators,
appropriate for the system
insulation rating, which are
mounted on a rigid metal
support to prevent flexing
of the mounting during
fuse or associated switch
operation

Mountings are available in
disconnect and nondisconnect configurations for
RBA fuses and a dropout
configuration for RDB fuses.
A non-disconnect mounting
permanently mounts the fuse
holder containing the refill
with tension type fuse clips
or bolted connections until it
is completely removed.
The disconnect mounting
permits a fuse to be opened,
closed, or even lifted out of
the mounting once it is
opened. An insulated stick
with a hook on the end of it is
used to perform the opening
and closing functions in a
disconnect mounting. The
insulated stick is referred to
as a switch stick.
Depending on the point of
application, it is often
necessary to attach a
discharge suppressor (filter,
condenser or muffler) to the
fuse unit. This metallic device
acts to retard, to varying
degrees, the gases and noise
associated with an expulsion
type fuse.
When the fuse element
melts inside the refill, an arc
is initiated and elongated. The
heat of the arc decomposes
the boric acid producing
water vapor and boric
anhydride. These two byproducts extinguish the arc
by blasting through it and exit
from the bottom of the fuse.
The gases are usually
assisted with the interruption
process by a spring loaded
mechanical device located
inside the fuse holder. In
addition to the exhaust
produced during interruption,
a significant amount of noise
also results. At this point, the
previously mentioned
suppressor is often used to
limit this discharge and noise.
The type of suppressor
installed depends upon the
requirements at the point of
application.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-53

2.7
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

RBA and RDB Details
Eaton’s renewable RBA or
RDB fuse unit is not totally
discarded after it interrupts a
fault. This makes the RBA
quite economical to use over
time. Normally, only the fuse
refill is discarded with the
RBA design.
The RBA power fuse
provides performance
characteristics especially
intended for power system
protection up to an
operational voltage of 34.5
kV. Because RBA fuses are
available in a wide range of
continuous current ratings
and time-current
characteristics, close fusing
can be achieved, maximizing
the protection and overall
coordination. The quality and
accuracy of the RBA design
and manufacturing process
ensures accurate initial and
ongoing melting time-current
characteristics. Proven RBA
power fuses perform as
intended and operate exactly
when and how they should,
and do not operate when
they should not operate. This
is a subtle but important
point.
Each individual RBA fuse
component is discussed
individually. Its makeup and
unique role in the protection
process are also discussed.

2
2
2
2

RBA Refill Unit
The internal parts of an RBA
refill unit are a calibrated
current responsive fuse
element and a parallel high
strength strain element, an
arcing rod, an auxiliary arcing
rod assembly, and a solid
boric acid liner which assists
with the interruption. The
lower end of the fuse
element is attached to an end
cap which is securely
crimped onto the lower end
of a glass-epoxy refill tube
and the upper end is brazed
or securely crimped to the
main arcing rod. The upper
end of the tube permits the
upper end of the arcing rod to
exit the refill tube through a
molded plug. At the upper
end of the refill unit, the plug
is sealed around the arcing
rod where it exits from the
refill tube. The lower end of
the refill unit is sealed with a
blowout disc to maintain the
integrity of the seal in RDB
outdoor applications. The seal
must be removed before an
exhaust control device is
fitted to a fuse holder for
indoor applications, to
prevent clogging the exhaust
control device.
The calibrated fuse element
assembly determines the
operational time-current
characteristics of the RBA
fuse. It is sensitive to the
heat produced by the amount
of current flowing. How,
when or if it melts for
different magnitudes of
current and amounts of time,
a particular current magnitude
experienced by the fuse is
indicated on the specific

time-current characteristic
curve for a particular fuse.
RBA fuse elements are
available in standard and
time-lag configurations. The
standard element assemblies
are made of pure silver with a
parallel Nichrome strain wire,
and the time-lag elements
have a calibrated tin alloy
joint. The Nichrome wire
relieves the fuse element of
any strain put on it by the
spring loaded arcing rod. This
parallel high resistance
vaporizes immediately after
the fuse element melts.
The heavy copper cylindrical
arcing rod is contained within
the main bore of the boric
acid liner and performs two
functions. Under normal
operating conditions, it
carries the continuous rated
current of the fuse. When the
fuse element melts during a
fault interruption, the acing
rod lengthens the arc as it is
pulled through the boric acid
liner. This backward
movement occurs because
the arcing rod is under spring
tension from the outside of
the refill.
An auxiliary arcing rod is
contained within the small
bore of the boric acid liner. It
plays a role in the proper
operation of the fuse under
low intensity fault conditions.
No load current is carried by
the auxiliary wire.

2
2
2
2
2
2
2
2
V14-T2-54

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

RBA Refill Unit Operation
Under fault conditions, the
fuse and strain elements melt
and the arcing rods pull the
arc back through the boric
acid liner. Intense heat from
the arc separates the
hydrated boric acid,
producing water vapor and
inert boric anhydride. This
expanding mixture
extinguishes the arc by
blasting through and deionizing it. The exhaust
caused by the interruption
exits from the bottom of the
fuse. The de-ionizing action
prevents the arc from restriking after a current zero.
RBA fuses are designed to
interrupt short-circuit currents
within 1/2 cycle at the next
current zero. Two different
chambers in parallel within
the solid boric acid liner
provide for selective
operation and interruption for
both low current and high
current faults using the
principles of de-ionization.
Low Current Fault
Interruption
When a low current fault
occurs, the main fuse and
strain elements melt and the
main and auxiliary arcing rods
start to draw through the
boric acid liner. At this stage,
the main rod circuit is open,
shorted out by the auxiliary
rod. The fine auxiliary coil
rapidly melts and the arc is
extinguished in the small
bore of the boric acid liner.
The arcing rod drawing no
arc, moves back to an open
position because of the
spring tension.

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

High Current Fault
Operation
A high fault current melts the
main fuse and strain element
and transfers to the auxiliary
fuse wire. In the small bore,
the high arc current creates a
high voltage causing the
arcing rod in the main bore to
restrike. The arcing rod then
draws the arc through the
main bore where it is quickly
extinguished.
RBA Refill Unit Ratings
RBA fuse refills are ANSI/
IEEE “E” rated. The “E”
rating defines a current
response that is intended to
produce a degree of electrical
interchangeability among
fuse manufacturers. A 100E
fuse carries 100 amperes or
below continuously and will
melt in a defined amount of
time for a defined range of
current above the fuse’s
continuous current
magnitude. This performance
will be the same for all fuses
with an E designation.
RBA Fuse Holder
An RBA fuse holder has a
glass epoxy tube which
encloses and supports the
fuse refill unit. Also inside the
tube is a spring and shunt
assembly, which makes an
electrical connection to the
top end of the refill unit. At
the ends, the fuse holder has
high conductivity copper alloy
ferrules, which include the
required features to interface
with a non-disconnect, or
disconnect mounting. The
holder delivers excellent
dielectric strength as well as
mechanical strength for
support purposes. The RBA
holder is not suitable for
outdoor applications.

RDB Fuse Holder
An RDB fuse holder has a
glass epoxy tube which is
coated with a protective gray
colored UV resistant coating
for outdoor application. This
tube encloses and supports
the fuse refill unit. Also inside
the tube is a spring and shunt
assembly which makes an
electrical connection to the
top end of the refill unit. The
RBD spring and shunt
assembly incorporates a
ballistic trip pin to unlatch the
fuse holder when the fuse
operates, initiating the
dropout action. At the ends,
the fuse holder has high
conductivity silver plated
copper alloy ferrules, which
include the required features
to interface with a dropout
mounting. The holder delivers
excellent dielectric strength
as well as mechanical
strength for support
purposes. The RDB holder
is designed for outdoor
applications with the UV
protected tube and silver
plated terminals.
After an RBA or RDB fuse
unit performs its function by
interrupting a fault, the fuse
holder is removed from its
mounting, opened and only
the fuse refill unit is replaced.
The fuse unit can then be
once again put back into
operation.

Spring and Shunt
Assembly
A spring and shunt assembly
comprises a stainless steel
helical spring that encloses a
tangle free flexible braided
high conductivity copper
shunt, which prevents the
spring from conducting load
or fault current. This
assembly attaches on the
lower end to the threaded
end of the refill unit, and at
the top end to the top contact
of the fuse holder. With the
spring and shunt assembly
properly attached to and
enclosed in the holder, the
refill arcing rod assembly is
put under spring tension,
ready to move the rod
through the boric acid liner.
Holder Contacts and
Hardware
The high conductivity cast
copper alloy upper and lower
contacts of the fuse holder
make low resistance
electrical connections
between the fuse refill and
the mounting. These contacts
also function to dissipate heat
in normal service.
The difference between nondisconnect and disconnect or
dropout type fuse holders is
the design of the top and
bottom contacts of the fuse
holder. Disconnect or dropout
electrical contacts permit the
fuse to be switch stick
operated in a compatible
disconnect or dropout type
mounting. A hookeye is
provided at the lower contact
of the fuse holder to allow
the fuse holder to be lifted
into the hinge end of the
mounting, and at the upper
contact to allow the fuse
holder to be swung to open
or close the fuse. A nondisconnect contact requires
the fuse unit to be supported
in a permanent position until
completely assembled into or
removed from a compatible
mounting.

2.7

RBA and RDB Mountings
Both non-disconnect and
disconnect mountings are
available for RBA power
fuses. Dropout mountings
are used with RDB fuse
units. Mountings provide
everything necessary to
safely install a compatible
RBA fuse unit into the
protected circuit. The rigid
mounting base is a metal
support to which the
porcelain or glass polyester
insulators are attached. They
insulate the live parts and the
installed fuse unit from the
mounting base and
everything beyond the base.
Live parts are available
without the insulators or
mounting base because
some applications have
unique mounting situations or
the customer may choose to
add additional value by
supplying the insulators and
base. It is still necessary to
mount the live parts and
insulators to a rigid support
structure to prevent the fuse
from unlatching due to
mechanical disturbances. It is
the responsibility of the
customer to make sure that
all mounting requirements
are met when using just the
live parts.
RBA non-disconnect
mountings can be supplied in
one of two configurations.
RBA-200 and RBA-400
mountings use upper and
lower fuse clamps to hold the
fuse unit in position. The
clamps securely locate each
end of the fuse holder into
the mounting. RBA-800
mountings hold the fuse unit
in place by solidly bolting it
into position. The type of nondisconnect mounting to be
used depends on the size and
configuration of the fuse unit.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-55

2.7
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

RBA disconnect and RDB
dropout mountings are
switch stick-operable,
facilitating opening, closing,
and fuse replacement. The
switch stick can be used to
open and close the fuse, and
also to lift the fuse into and
out of the mounting. This
keeps the operator well clear
of any live parts during fuse
removal. The lower end of
the mounting is the hinged
end and the upper end is the
latched end and they work in
conjunction with the
compatible contacts of the
fuse holder. Positive electrical
connections are maintained
at both ends of the mounting
through the spring fingers at
the lower end and clip type
contacts on the upper end.
The spring fingers are
compressed on closing in of
the fuse holder.
RBA Exhaust Control Devices
For indoor applications, phaseto-phase clearances and
clearances to ground are
generally restricted, and
exhaust control devices must
be used with RBA indoor
expulsion fuses to retard the
gases and reduce the noise
associated with this type of
fuse operation. Eaton offers
three devices called the
condenser, the discharge filter
and the high capacity discharge
filter—the high capacity
discharge filter has limited
application at a specific voltage
level. Other manufacturers
refer to such devices as
suppressors or silencers.

The exhaust control device is
threaded onto the bottom of an
RBA fuse holder to minimize
the noise and exhaust while
containing the arc within the
fuse during interruption, and
also to clamp the lower end of
the fuse refill unit into the fuse
holder to ensure an adequately
tight electrical and mechanical
connection to minimize contact
resistance and enable thermal
conduction out of the refill unit.
Exhaust control devices are
metallic containers with copper
screen inside to absorb and
dissipate arc heat and
condense steam to water.
Although the inner and outer
metals of the condenser and
discharge filter are similar, the
internal designs and venting
methods are different. A
condenser can be identified by
the very restrictive bottom plate
with only one small hole to
allow the slow release, after
interruption, of water absorbed
by the condenser during a fuse
interruption. A discharge filter is
very less restrictive, and acts
only to de-ionize the exhaust
gases and reduce the flow rate
of the discharge. The flow
restriction in a condenser
causes a back-pressure in the
fuse which reduces the ability
of the fuse to interrupt higher
current faults.

RBA/RDB Interruption and
Protection
The operation of RBA and
RDB fuses must be
considered for three sets of
conditions:
●

Normal loading—This is
when the circuit current is
below the allowable
continuous current or
within the limits of the
allowable short-time
overload current shown on
Page V14-T2-8 of the
Expulsion Fuse
Introduction, for the
particular set of application
conditions. Under such
normal loading, the fuse is
not subject to any
conditions that would
degrade its long term
integrity, or affect its ability
to correctly interrupt fault
conditions.

Note: If the current is at or below
the allowable continuous current
for the particular set of
conditions, that is, allowing for an
elevated ambient temperature,
high altitude, or an enclosure that
restricts natural cooling, the
temperature rise and maximum
temperature of the fuse will be
below the allowable limits stated
in IEEE Std. C37.40™-2003.

2
2
2
2
2
2
2
2
2
V14-T2-56

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Note: If temporary overloads are
below the temporary overload
curve, with values based on the
allowable continuous current, not
on the rated continuous current,
the fuse unit or refill unit,
although it may be subject to
temporarily slightly elevated
temperatures, will not be subject
to conditions that could affect its
long term integrity or degrade its
ability to correctly interrupt fault
conditions.
Note: After the fuse has been
subjected to a temporary
overload as indicated on Page
V14-T2-8, the current should be
reduced to no more than the
normal circuit full load condition—
typically (fuse rated continuous
current) /1.4 for a period long
enough for any temporary excess
heat to be dissipated—typically 2
hours minimum.
●

Overloading—This occurs
if the circuit current
exceeds the allowable
short-time overload
conditions shown on Page
V14-T2-8 of the Expulsion
Fuse Introduction, but is
below 240% (for fuses
rated 100E or below) or
264% (for fuses rated
above 100E).

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

If the fuse is exposed to
these overload conditions,
the long term integrity of the
fuse refill unit can be
degraded and its ability to
correctly interrupt fault
conditions may be seriously
compromised.
Note: With a fuse unit or fuse
refill unit rated 100E or less, the
element may melt at any current
between 200% and 240% of the
E rating, and with a fuse unit or
refill unit rated more than 100E,
the element may melt at any
current between 220% and
264% of the E rating. These 10%
ranges allow for variations
between fuses because of
manufacturing tolerances, and so
on, on the fuse assembly. The
minimum melting current of the
fuse could be anywhere in the
range between the value on the
minimum-melting time-current
characteristic and the value on
the total-clearing time-current
characteristic. At this end of the
curve, the total-clearing and
maximum-melting characteristics
are effectively the same. The
maximum values of the range are
quoted here because this is the
lower limit of the current at which
it is known that the fuse element
will melt.

●

Faults—This covers all
conditions from about
240% for a fuse rating of
100E or less, or 264% for a
fuse rating greater than
100E up to the interrupting
rating of the fuse. The fuse
will interrupt the fault
current in a time indicated
by the published fuse timecurrent characteristic
curves. Interruption occurs
at a natural current zero of
the fault current, when the
dielectric strength of the
fuse withstands the
combination of power
frequency recovery voltage
and transient recovery
voltage.

The noise of the operation
and the quantity of exhaust
products is reduced in indoor
RBA applications by the use
of an exhaust control device
which partially absorbs and
de-ionizes the exhaust gases.
In outdoor applications, RDB
fuses are exhausted to
atmosphere.

2.7

The rated maximum
voltage of RBA or RDB
power fuse is the highest
power frequency system
voltage at which the fuse is
designed to operate. The
dielectric withstand level
corresponds to insulation
levels of power class
equipment. Rated maximum
voltage levels for RBA power
fuses are: 8.3, 15.5, 25.5 and
38.0 kV.

2
2
2
2
2
2

Fuses, including RBA/RDB
power fuses, should never be
applied where the available
fault current at the fuse
location exceeds the rated
maximum interrupting
current of the fuse. The rated
maximum interrupting
current of an RBA fuse is the
rms value of the symmetrical
component (AC component)
of the highest current which
the RBA is has been
demonstrated to be able to
successfully interrupt under
any condition of asymmetry.
RBA interrupting ratings are
shown in the table on Page
V14-T2-59. The rated
continuous current of an RBA
or RDB power fuse should at
least equal or preferably
exceed the maximum load
current where the fuse is
applied. Fuses are designed
to carry their rated
continuous current without
exceeding the temperature
rise outlined in IEEE
standards. RBA and RDB
fuses are available with
continuous current ratings up
to 720 amperes current
ratings and carry an “E”
designation.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-57

2.7
2
2

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

Catalog Number Selection
RBA and RBT Fuse Units

15 RBA2 100E

2
Maximum kV
8 = 8.3 kV
15 = 15.5 kV
25 = 25.5 kV
38 = 38 kV

2
2
2

Type
RBA2
RBA4
RBT2
RBT4

2
2

Ampere
Rating
0.5
65E
3
80E
5E
100E
7E
125E
10E
150E
20E
175E
25E
200E
30E
250E
40E
300E
50E
400E

2
2

RBA and RBT Fuse Holders, Mounting and Accessories

2

15 RBA2 P NM

2

Maximum kV
8 = 8.3 kV
15 = 15.5 kV
25 = 25.5 kV
38 = 38 kV

2
2
2

Type
RBA2
RBA4
RBA8
RDB4
RDB8

Insulator
P = Porcelain
G = Glass polyester
H = Porcelain, high
LIWL (BIL)

2

COND
DH
DL
DM
FLTR
HC-FLTR
IDH
INH
INH-B

2

NH
NL
NM
UL
UM
VL
VM

2
2

Hardware
= Condenser
= Disconnect fuse holder
= Disconnect live parts
= Disconnect mounting
= Filter
= High capacity filter
= Indicating disconnect fuse holder
= Indicating non-disconnect fuse
holder
= Indicating non-disconnect fuse
holder, bolt in
= Non-disconnect fuse holder
= Non-disconnect live parts
= Non-disconnect mounting
= Underhung live parts
= Underhung mounting
= Vertical live parts
= Vertical mounting

2
2
2
2
2
2
2
2
2
2
2
V14-T2-58

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

2.7

Interrupting Ratings

2

RBA and RBT Fuse Interrupting Ratings

2

Fuse Nominal
Rated Voltage
Rating kV

Maximum System
Voltage kV

RDB2 Outdoor Vented
rms Symmetrical kA

RBA2 Indoor with Filter
rms Symmetrical kA

RDB2 Indoor with Condenser
rms Symmetrical kA

2.4

2.75

19.0

19.0

10.0

4.16

4.8

19.0

19.0

10.0

4.8

5.5

19.0

19.0

10.0

7.2

8.3

16.6

16.6

10.0

13.8

14.4

14.4

14.4

8.0

14.4

15.5

14.4

14.4

8.0

23

25.5

10.5

10.5

6.3

34.5

38

6.9

6.9

5.0

2
2
2
2
2
2
2

RBA and RBT Fuse Interrupting Ratings, continued
Fuse Nominal
Rated Voltage
Rating kV

Maximum System
Voltage kV

RDB4/8 Outdoor Vented
rms Symmetrical kA

RBA4/8 Indoor with Filter
rms Symmetrical kA

RDA4/4 Indoor with
Condenser
rms Symmetrical kA

RBA4/8 Indoor with
High Capacity Filter
rms Symmetrical kA

2.4

2.75

37.7

37.7

20.0

—

4.16

4.8

37.5

37.5

20.0

—

4.8

5.5

37.5

37.5

20.0

—

7.2

8.3

29.4

29.4

16.0

—

13.8

14.4

29.4

29.4

12.5

36.0

14.4

15.5

29.4

29.4

12.5

—

23

25.5

21.0

21.0

10.0

—

34.5

38

16.8

16.8

10.0

—

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-59

2.7

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

2

Product Selection

2

8RBA2 and 8RBA4 Type Standard Speed and 8RBT2 and 8RBT4 Time Lag Fuse Refill Units
Performance Curves

2
2
2
2
2
2
2
2
2
2
2

Voltage (kV)

Standard Speed Time Lag
Catalog
Number

Catalog
Number

Approximate
Shipping Weight
Lbs (kg)

Standard Speed

Time Lag

Nominal

Maximum

Ampere
Rating

Minimum
Melting

Total
Clearing

Minimum
Melting

Total
Clearing

7.2

8.3

10E

8RBA2-10E

—

1.0 (0.5)

TC62882301

TC66701401

—

—

7.2

8.3

15E

8RBA2-15E

—

1.0 (0.5)

TC62882301

TC66701401

—

—

7.2

8.3

20E

8RBA2-20E

8RBT2-20E

1.0 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

7.2

8.3

25E

8RBA2-25E

8RBT2-25E

1.0 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

7.2

8.3

30E

8RBA2-30E

8RBT2-30E

1.0 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

7.2

8.3

40E

8RBA2-40E

8RBT2-40E

1.0 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

7.2

8.3

50E

8RBA2-50E

8RBT2-50E

1.0 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

7.2

8.3

65E

8RBA2-65E

8RBT2-65E

1.0 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

7.2

8.3

80E

8RBA2-80E

8RBT2-80E

1.0 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

7.2

8.3

100E

8RBA2-100E

8RBT2-100E

1.0 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

7.2

8.3

125E

8RBA2-125E

8RBT2-125E

1.0 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

7.2

8.3

150E

8RBA2-150E

8RBT2-150E

1.0 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

7.2

8.3

175E

8RBA2-175E

—

1.0 (0.5)

TC62882301

TC66701401

—

—

7.2

8.3

200E

8RBA2-200E

8RBT2-200E

1.0 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

7.2

8.3

0.5

8RBA4-.5

—

2.1 (1.0)

TC62886101

TC66701501

—

—

7.2

8.3

3

8RBA4-3

—

2.1 (1.0)

TC62886101

TC66701501

—

—

7.2

8.3

5E

8RBA4-5E

—

2.1 (1.0)

TC62886101

TC66701501

—

—

7.2

8.3

7E

8RBA4-7E

—

2.1 (1.0)

TC62886101

TC66701501

—

—

7.2

8.3

10E

8RBA4-10E

—

2.1 (1.0)

TC62886101

TC66701501

—

—

7.2

8.3

15E

8RBA4-15E

—

2.1 (1.0)

TC62886101

TC66701501

—

—

7.2

8.3

20E

8RBA4-20E

8RBT4-20E

2.1 (1.0)

TC62886101

TC66701501

TC62886501

TC66701201

7.2

8.3

25E

8RBA4-25E

8RBT4-25E

2.1 (1.0)

TC62886101

TC66701501

TC62886501

TC66701201

7.2

8.3

30E

8RBA4-30E

8RBT4-30E

2.1 (1.0)

TC62886101

TC66701501

TC62886501

TC66701201

7.2

8.3

40E

8RBA4-40E

8RBT4-40E

2.1 (1.0)

TC62886101

TC66701501

TC62886501

TC66701201

7.2

8.3

50E

8RBA4-50E

8RBT4-50E

2.1 (1.0)

TC62886101

TC66701501

TC62886501

TC66701201

2

7.2

8.3

65E

8RBA4-65E

8RBT4-65E

2.1 (1.0)

TC62886101

TC66701501

TC62886501

TC66701201

7.2

8.3

70E

8RBA4-80E

8RBT4-80E

2.1 (1.0)

TC62886101

TC66701501

TC62886501

TC66701201

2

7.2

8.3

100E

8RBA4-100E

8RBT4-100E

2.1 (1.0)

TC62886101

TC66701501

TC62886501

TC66701201

7.2

8.3

125E

8RBA4-125E

8RBT4-125E

2.1 (1.0)

TC62886101

TC66701501

TC62886501

TC66701201

7.2

8.3

150E

8RBA4-150E

8RBT4-150E

2.1 (1.0)

TC62886101

TC66701501

TC62886501

TC66701201

2

7.2

8.3

175E

8RBA4-175E

—

2.1 (1.0)

TC62886101

TC66701501

—

—

7.2

8.3

200E

8RBA4-200E

8RBT4-200E

2.1 (1.0)

TC62886101

TC66701501

TC62886501

TC66701201

2

7.2

8.3

250E

8RBA4-250E

8RBT4-250E

2.1 (1.0)

TC62886101

TC66701501

TC63943501

TC66701101

7.2

8.3

300E

8RBA4-300E

8RBT4-300E

2.1 (1.0)

TC62886101

TC66701501

TC63943501

TC66701101

7.2

8.3

400E

8RBA4-400E

8RBT4-400E

2.1 (1.0)

TC62886101

TC66701501

TC63943501

TC66701101

2

7.2

8.3

450E

(2) 8RBA4-250E

(2) 8RBT2-250E

—

TC62886102

TC66701001

TC63943502

TC66700901

7.2

8.3

540E

(2) 8RBA4-300E

(2) 8RBT2-300E

—

TC62886102

TC66701001

TC63943502

TC66700901

2

7.2

8.3

720E

(2) 8RBA4-400E

(2) 8RBT2-400E

—

TC62886102

TC66701001

TC63943502

TC66700901

2
2
2
2
2
2

2

2

2
2
2
V14-T2-60

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

2.7

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

15RBA2 and 15RBA4 Type Standard Speed and 15RBT2 and 15RBT4 Time Lag Fuse Refill Units

2

Performance Curves
Voltage (kV)

Standard Speed Time Lag
Catalog
Number

Catalog
Number

Approximate
Shipping Weight
Lbs (kg)

Standard Speed

2

Time Lag

Nominal

Maximum

Ampere
Rating

Minimum
Melting

Total
Clearing

Minimum
Melting

Total
Clearing

14

16

10E

15RBA2-10E

—

1.1 (0.5)

TC62882301

TC66701401

—

—

14

16

15E

15RBA2-15E

—

1.1 (0.5)

TC62882301

TC66701401

—

—

14

16

20E

15RBA2-20E

15RBT2-20E

1.1 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

14

16

25E

15RBA2-25E

15RBT2-25E

1.1 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

14

16

30E

15RBA2-30E

15RBT2-30E

1.1 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

14

16

40E

15RBA2-40E

15RBT2-40E

1.1 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

14

16

50E

15RBA2-50E

15RBT2-50E

1.1 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

14

16

65E

15RBA2-65E

15RBT2-65E

1.1 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

14

16

80E

15RBA2-80E

15RBT2-80E

1.1 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

14

16

100E

15RBA2-100E

15RBT2-100E

1.1 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

14

16

125E

15RBA2-125E

15RBT2-125E

1.1 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

14

16

150E

15RBA2-150E

15RBT2-150E

1.1 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

14

16

175E

15RBA2-175E

—

1.1 (0.5)

TC62882301

TC66701401

—

—

14

16

200E

15RBA2-200E

15RBT2-200E

1.1 (0.5)

TC62882301

TC66701401

TC62886301

TC66701301

14

16

0.5

15RBA4-.5

—

2.3 (1.05)

TC62886101

TC66701501

—

—

14

16

3

15RBA4-3

—

2.3 (1.05)

TC62886101

TC66701501

—

—

14

16

5E

15RBA4-5E

—

2.3 (1.05)

TC62886101

TC66701501

—

—

14

16

7E

15RBA4-7E

—

2.3 (1.05)

TC62886101

TC66701501

—

—

14

16

10E

15RBA4-10E

—

2.3 (1.05)

TC62886101

TC66701501

—

—

14

16

15E

15RBA4-15E

—

2.3 (1.05)

TC62886101

TC66701501

—

—

14

16

20E

15RBA4-20E

15RBT4-20E

2.3 (1.05)

TC62886101

TC66701501

TC62886501

TC66701201

14

16

25E

15RBA4-25E

15RBT4-25E

2.3 (1.05)

TC62886101

TC66701501

TC62886501

TC66701201

14

16

30E

15RBA4-30E

15RBT4-30E

2.3 (1.05)

TC62886101

TC66701501

TC62886501

TC66701201

14

16

40E

15RBA4-40E

15RBT4-40E

2.3 (1.05)

TC62886101

TC66701501

TC62886501

TC66701201

14

16

50E

15RBA4-50E

15RBT4-50E

2.3 (1.05)

TC62886101

TC66701501

TC62886501

TC66701201

14

16

65E

15RBA4-65E

15RBT4-65E

2.3 (1.05)

TC62886101

TC66701501

TC62886501

TC66701201

14

16

70E

15RBA4-80E

15RBT4-80E

2.3 (1.05)

TC62886101

TC66701501

TC62886501

TC66701201

14

16

100E

15RBA4-100E

15RBT4-100E

2.3 (1.05)

TC62886101

TC66701501

TC62886501

TC66701201

14

16

125E

15RBA4-125E

15RBT4-125E

2.3 (1.05)

TC62886101

TC66701501

TC62886501

TC66701201

14

16

150E

15RBA4-150E

15RBT4-150E

2.3 (1.05)

TC62886101

TC66701501

TC62886501

TC66701201

14

16

175E

15RBA4-175E

—

2.3 (1.05)

TC62886101

TC66701501

—

—

14

16

200E

15RBA4-200E

15RBT4-200E

2.3 (1.05)

TC62886101

TC66701501

TC62886501

TC66701201

14

16

250E

15RBA4-250E

15RBT4-250E

2.3 (1.05)

TC62886101

TC66701501

TC63943501

TC66701101

14

16

300E

15RBA4-300E

15RBT4-300E

2.3 (1.05)

TC62886101

TC66701501

TC63943501

TC66701101

14

16

400E

15RBA4-400E

15RBT4-400E

2.3 (1.05)

TC62886101

TC66701501

TC63943501

TC66701101

14

16

450E

(2) 15RBA4-250E (2) 15RBT2-250E —

TC62886102

TC66701001

TC63943502

TC66700901

14

16

540E

(2) 15RBA4-300E (2) 15RBT2-300E —

TC62886102

TC66701001

TC63943502

TC66700901

14

16

720E

(2) 15RBA4-400E (2) 15RBT2-400E —

TC62886102

TC66701001

TC63943502

TC66700901

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-61

2.7
2
2

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

25RBA2 and 25RBA4 Type Standard Speed and 25RBT2 and 25RBT4 Time Lag Fuse Refill Units
Performance Curves
Voltage (kV)

Standard Speed Time Lag
Catalog
Number

Catalog
Number

Approximate
Shipping Weight
Lbs (kg)

Standard Speed

Time Lag

Nominal

Maximum

Ampere
Rating

23

26

10E

25RBA2-10E

—

1.3 (0.6)

TC62882301

TC66701401

—

—

23

26

15E

25RBA2-15E

—

1.3 (0.6)

TC62882301

TC66701401

—

—

23

26

20E

25RBA2-20E

25RBT2-20E

1.3 (0.6)

TC62882301

TC66701401

TC62886301

TC66701301

23

26

25E

25RBA2-25E

25RBT2-25E

1.3 (0.6)

TC62882301

TC66701401

TC62886301

TC66701301

23

26

30E

25RBA2-30E

25RBT2-30E

1.3 (0.6)

TC62882301

TC66701401

TC62886301

TC66701301

23

26

40E

25RBA2-40E

25RBT2-40E

1.3 (0.6)

TC62882301

TC66701401

TC62886301

TC66701301

23

26

50E

25RBA2-50E

25RBT2-50E

1.3 (0.6)

TC62882301

TC66701401

TC62886301

TC66701301

23

26

65E

25RBA2-65E

25RBT2-65E

1.3 (0.6)

TC62882301

TC66701401

TC62886301

TC66701301

23

26

80E

25RBA2-80E

25RBT2-80E

1.3 (0.6)

TC62882301

TC66701401

TC62886301

TC66701301

23

26

100E

25RBA2-100E

25RBT2-100E

1.3 (0.6)

TC62882301

TC66701401

TC62886301

TC66701301

23

26

125E

25RBA2-125E

25RBT2-125E

1.3 (0.6)

TC62882301

TC66701401

TC62886301

TC66701301

23

26

150E

25RBA2-150E

25RBT2-150E

1.3 (0.6)

TC62882301

TC66701401

TC62886301

TC66701301

23

26

175E

25RBA2-175E

—

1.3 (0.6)

TC62882301

TC66701401

—

—

23

26

200E

25RBA2-200E

25RBT2-200E

1.3 (0.6)

TC62882301

TC66701401

TC62886301

TC66701301

23

26

0.5

25RBA4-.5

—

2.7 (1.25)

TC62886101

TC66701501

—

—

23

26

3

25RBA4-3

—

2.7 (1.25)

TC62886101

TC66701501

—

—

23

26

5E

25RBA4-5E

—

2.7 (1.25)

TC62886101

TC66701501

—

—

2

23

26

7E

25RBA4-7E

—

2.7 (1.25)

TC62886101

TC66701501

—

—

23

26

10E

25RBA4-10E

—

2.7 (1.25)

TC62886101

TC66701501

—

—

2

23

26

15E

25RBA4-15E

—

2.7 (1.25)

TC62886101

TC66701501

—

—

23

26

20E

25RBA4-20E

25RBT4-20E

2.7 (1.25)

TC62886101

TC66701501

TC62886501

TC66701201

23

26

25E

25RBA4-25E

25RBT4-25E

2.7 (1.25)

TC62886101

TC66701501

TC62886501

TC66701201

23

26

30E

25RBA4-30E

25RBT4-30E

2.7 (1.25)

TC62886101

TC66701501

TC62886501

TC66701201

23

26

40E

25RBA4-40E

25RBT4-40E

2.7 (1.25)

TC62886101

TC66701501

TC62886501

TC66701201

23

26

50E

25RBA4-50E

25RBT4-50E

2.7 (1.25)

TC62886101

TC66701501

TC62886501

TC66701201

23

26

65E

25RBA4-65E

25RBT4-65E

2.7 (1.25)

TC62886101

TC66701501

TC62886501

TC66701201

23

26

70E

25RBA4-80E

25RBT4-80E

2.7 (1.25)

TC62886101

TC66701501

TC62886501

TC66701201

23

26

100E

25RBA4-100E

25RBT4-100E

2.7 (1.25)

TC62886101

TC66701501

TC62886501

TC66701201

23

26

125E

25RBA4-125E

25RBT4-125E

2.7 (1.25)

TC62886101

TC66701501

TC62886501

TC66701201

23

26

150E

25RBA4-150E

25RBT4-150E

2.7 (1.25)

TC62886101

TC66701501

TC62886501

TC66701201

23

26

175E

25RBA4-175E

—

2.7 (1.25)

TC62886101

TC66701501

—

—

23

26

200E

25RBA4-200E

25RBT4-200E

2.7 (1.25)

TC62886101

TC66701501

TC62886501

TC66701201

23

26

250E

25RBA4-250E

25RBT4-250E

2.7 (1.25)

TC62886101

TC66701501

TC63943501

TC66701101

23

26

300E

25RBA4-300E

25RBT4-300E

2.7 (1.25)

TC62886101

TC66701501

TC63943501

TC66701101

23

26

450E

(2) 25RBA4-250E (2) 25RBT2-250E 2.7 (1.25)

TC62886102

TC66701001

TC63943502

TC66700901

23

26

540E

(2) 25RBA4-300E (2) 25RBT2-300E —

TC62886102

TC66701001

TC63943502

TC66700901

2
2
2
2
2
2
2
2
2
2
2

2
2
2
2
2
2
2
2
2
2

Minimum
Melting

Total
Clearing

Minimum
Melting

Total
Clearing

2
2
2
2
2
V14-T2-62

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

2.7

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

38RBA4 and 38RBA4 Type Standard Speed and 38RBT2 and 238RBT4 Time Lag Fuse Refill Units

2

Performance Curves
Voltage (kV)

Standard Speed Time Lag
Catalog
Number

Catalog
Number

Approximate
Shipping Weight
Lbs (kg)

Standard Speed

2

Time Lag

Nominal

Maximum

Ampere
Rating

Minimum
Melting

Total
Clearing

Minimum
Melting

Total
Clearing

35

38

10E

38RBA2-10E

—

1.4 (0.65)

TC62882301

TC66701401

—

—

35

38

15E

38RBA2-15E

—

1.4 (0.65)

TC62882301

TC66701401

—

—

35

38

20E

38RBA2-20E

38RBT2-20E

1.4 (0.65)

TC62882301

TC66701401

TC62886301

TC66701301

35

38

25E

38RBA2-25E

38RBT2-25E

1.4 (0.65)

TC62882301

TC66701401

TC62886301

TC66701301

35

38

30E

38RBA2-30E

38RBT2-30E

1.4 (0.65)

TC62882301

TC66701401

TC62886301

TC66701301

35

38

40E

38RBA2-40E

38RBT2-40E

1.4 (0.65)

TC62882301

TC66701401

TC62886301

TC66701301

35

38

50E

38RBA2-50E

38RBT2-50E

1.4 (0.65)

TC62882301

TC66701401

TC62886301

TC66701301

35

38

65E

38RBA2-65E

38RBT2-65E

1.4 (0.65)

TC62882301

TC66701401

TC62886301

TC66701301

35

38

80E

38RBA2-80E

38RBT2-80E

1.4 (0.65)

TC62882301

TC66701401

TC62886301

TC66701301

35

38

100E

38RBA2-100E

38RBT2-100E

1.4 (0.65)

TC62882301

TC66701401

TC62886301

TC66701301

35

38

125E

38RBA2-125E

38RBT2-125E

1.4 (0.65)

TC62882301

TC66701401

TC62886301

TC66701301

35

38

150E

38RBA2-150E

38RBT2-150E

1.4 (0.65)

TC62882301

TC66701401

TC62886301

TC66701301

35

38

175E

38RBA2-175E

—

1.4 (0.65)

TC62882301

TC66701401

—

—

35

38

200E

38RBA2-200E

38RBT2-200E

1.4 (0.65)

TC62882301

TC66701401

TC62886301

TC66701301

35

38

0.5

38RBA4-.5

—

3.1 (1.4)

TC62886101

TC66701501

—

—

35

38

3

38RBA4-3

—

3.1 (1.4)

TC62886101

TC66701501

—

—

35

38

5E

38RBA4-5E

—

3.1 (1.4)

TC62886101

TC66701501

—

—

35

38

7E

38RBA4-7E

—

3.1 (1.4)

TC62886101

TC66701501

—

—

35

38

10E

38RBA4-10E

—

3.1 (1.4)

TC62886101

TC66701501

—

—

35

38

15E

38RBA4-15E

—

3.1 (1.4)

TC62886101

TC66701501

—

—

35

38

20E

38RBA4-20E

38RBT4-20E

3.1 (1.4)

TC62886101

TC66701501

TC62886501

TC66701201

35

38

25E

38RBA4-25E

38RBT4-25E

3.1 (1.4)

TC62886101

TC66701501

TC62886501

TC66701201

35

38

30E

38RBA4-30E

38RBT4-30E

3.1 (1.4)

TC62886101

TC66701501

TC62886501

TC66701201

35

38

40E

38RBA4-40E

38RBT4-40E

3.1 (1.4)

TC62886101

TC66701501

TC62886501

TC66701201

35

38

50E

38RBA4-50E

38RBT4-50E

3.1 (1.4)

TC62886101

TC66701501

TC62886501

TC66701201

35

38

65E

38RBA4-65E

38RBT4-65E

3.1 (1.4)

TC62886101

TC66701501

TC62886501

TC66701201

35

38

70E

38RBA4-80E

38RBT4-80E

3.1 (1.4)

TC62886101

TC66701501

TC62886501

TC66701201

35

38

100E

38RBA4-100E

38RBT4-100E

3.1 (1.4)

TC62886101

TC66701501

TC62886501

TC66701201

35

38

125E

38RBA4-125E

38RBT4-125E

3.1 (1.4)

TC62886101

TC66701501

TC62886501

TC66701201

35

38

150E

38RBA4-150E

38RBT4-150E

3.1 (1.4)

TC62886101

TC66701501

TC62886501

TC66701201

35

38

175E

38RBA4-175E

—

3.1 (1.4)

TC62886101

TC66701501

—

—

35

38

200E

38RBA4-200E

38RBT4-200E

3.1 (1.4)

TC62886101

TC66701501

TC62886501

TC66701201

35

38

250E

38RBA4-250E

38RBT4-250E

3.1 (1.4)

TC62886101

TC66701501

TC63943501

TC66701101

35

38

300E

38RBA4-300E

38RBT4-300E

3.1 (1.4)

TC62886101

TC66701501

TC63943501

TC66701101

2
2
2
2
2
2
2
2
2
2
2
2
2

35

38

450E

(2) 38RBA4-250E (2) 38RBT2-250E —

TC62886102

TC66701001

TC63943502

TC66700901

35

38

540E

(2) 38RBA4-300E (2) 38RBT2-300E —

TC62886102

TC66701001

TC63943502

TC66700901

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-63

2.7
2
2
2

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

RBA2 Fuse Holders, Mountings and Live Parts

Style

Fuse Holder
Catalog
Number

Mounting
Porcelain
Catalog
Number

Voltage (kV)
Nominal

Ampere
Maximum Rating

LIWL
(BIL)

4.8

5.5

60

Live Parts
Catalog
Number

Spring and Shunt
Assembly
Catalog
Number

Disconnect non-indicating

8RBA2-DH

5RBA2-PDM

5RBA2-GDM

15RBA2-DL

8RBA2-ISHNT

2

Non-disconnect non-indicating

8RBA2-NH

5RBA2-PNM

5RBA2-GNM

15RBA2-NL

8RBA2-ISHNT

Disconnect indicating

8RBA2-IDH

5RBA2-PDM

5RBA2-GDM

15RBA2-DL

8RBA2-ISHNT

2

Non-disconnect indicating

8RBA2-INH

5RBA2-PNM

5RBA2-GNM

15RBA2-NL

8RBA2-ISHNT

Non-disconnect indicating bolt in

8RBA2-INH-B

5RBA8-PNM

5RBA8-GNM

15RBA8-NL

8RBA2-ISHNT

Disconnect non-indicating

8RBA2-DH

8RBA2-PDM

8RBA2-GDM

15RBA2-DL

8RBA2-ISHNT

2

Non-disconnect non-indicating

8RBA2-NH

8RBA2-PNM

8RBA2-GNM

15RBA2-NL

8RBA2-ISHNT

Disconnect indicating

8RBA2-IDH

8RBA2-PDM

8RBA2-GDM

15RBA2-DL

8RBA2-ISHNT

2

Non-disconnect indicating

8RBA2-INH

8RBA2-PNM

8RBA2-GNM

15RBA2-NL

8RBA2-ISHNT

Non-disconnect indicating bolt in

8RBA2-INH-B

8RBA8-PNM

8RBA8-GNM

15RBA8-NL

8RBA2-ISHNT

Disconnect non-indicating

15RBA2-DH

14RBA2-PDM

14RBA2-GDM

15RBA2-DL

15RBA2-ISHNT

Non-disconnect non-indicating

15RBA2-NH

14RBA2-PNM

14RBA2-GNM

15RBA2-NL

15RBA2-ISHNT

Disconnect indicating

15RBA2-IDH

14RBA2-PDM

14RBA2-GDM

15RBA2-DL

15RBA2-ISHNT

Non-disconnect indicating

15RBA2-INH

14RBA2-PNM

14RBA2-GNM

15RBA2-NL

15RBA2-ISHNT

Non-disconnect indicating bolt in

15RBA2-INH-B 14RBA8-PNM

14RBA8-GNM

15RBA8-NL

15RBA2-ISHNT

Disconnect non-indicating

15RBA2-DH

15RBA2-PDM

—

15RBA2-DL

15RBA2-ISHNT

Non-disconnect non-indicating

15RBA2-NH

15RBA2-PNM

—

15RBA2-NL

15RBA2-ISHNT

Disconnect indicating

15RBA2-IDH

15RBA2-PDM

—

15RBA2-DL

15RBA2-ISHNT

Non-disconnect indicating

15RBA2-INH

15RBA2-PNM

—

15RBA2-NL

15RBA2-ISHNT

Non-disconnect indicating bolt in

15RBA2-INH-B 15RBA8-PNM

—

15RBA8-NL

15RBA2-ISHNT

Disconnect non-indicating

25RBA2-DH

25RBA2-PDM

—

38RBA2-DL

25RBA2-ISHNT

Non-disconnect non-indicating

25RBA2-NH

25RBA2-PNM

—

38RBA2-NL

25RBA2-ISHNT

Disconnect indicating

25RBA2-IDH

25RBA2-PDM

—

38RBA2-DL

25RBA2-ISHNT

Non-disconnect indicating

25RBA2-INH

25RBA2-PNM

—

38RBA2-NL

25RBA2-ISHNT

Non-disconnect indicating bolt in

25RBA2-INH-B 25RBA8-PNM

—

38RBA8-NL

25RBA2-ISHNT

Disconnect non-indicating

38RBA2-DH

38RBA2-PDM

—

38RBA2-DL

38RBA2-ISHNT

Non-disconnect non-indicating

38RBA2-NH

38RBA2-PNM

—

38RBA2-NL

38RBA2-ISHNT

Disconnect indicating

38RBA2-IDH

38RBA2-PDM

—

38RBA2-DL

38RBA2-ISHNT

Non-disconnect indicating

38RBA2-INH

38RBA2-PNM

—

38RBA2-NL

38RBA2-ISHNT

Non-disconnect indicating bolt in

38RBA2-INH-B 38RBA8-PNM

—

38RBA8-NL

38RBA2-ISHNT

2

2

7.2

13.8

8.3

15.5

10E–200E

Glass Polyester
Catalog
Number

10E–200E

10E–200E

75

95

2
2
2

13.8

15.5

10E–200E

110

2
2
2

23

25.5

10E–200E

150

2
2
2

34.5

38

10E–200E

150

2
2
2

RBA2 Exhaust Control Devices

2

Voltage (kV)

2

Nominal

Maximum

Ampere Rating

LIWL (BIL)

Style

Exhaust Control
Devices
Catalog
Number

4.8–13.8

5.5–15.5

10E–200E

—

Condenser (1 pack)

RBA2-COND-1

—

Condenser (3 pack)

RBA2-COND

—

Filter (1 pack)

RBA2-FLTR-1

—

Filter (3 pack)

RBA2-FLTR

—

Condenser (1 pack)

RBA2-COND-1

—

Condenser (3 pack)

RBA2-COND

—

Filter (1 pack)

RBA2-FLTR-1

—

Filter (3 pack)

RBA2-FLTR

2
2
2

23–34.5

2
2

25.5–38

10E–200E

2
2
V14-T2-64

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

2.7

RBA4 Fuse Holders, Mountings and Live Parts
Voltage (kV)

Mounting
Porcelain
Catalog
Number

Glass Polyester
Catalog
Number

Live Parts
Catalog
Number

Spring and Shunt
Assembly
Catalog
Number

5RBA4-PDM

5RBA4-GDM

15RBA4-DL

8RBA4-ISHNT

Nominal

Ampere
Maximum Rating

LIWL
(BIL)

Style

Fuse Holder
Catalog
Number

4.8

5.5

60

Disconnect non-indicating

8RBA4-DH

Non-disconnect non-indicating

8RBA4-NH

5RBA4-PNM

5RBA4-GNM

15RBA4-NL

8RBA4-ISHNT

Disconnect indicating

8RBA4-IDH

5RBA4-PDM

5RBA4-GDM

15RBA4-DL

8RBA4-ISHNT

Non-disconnect indicating

8RBA4-INH

5RBA4-PNM

5RBA4-GNM

15RBA4-NL

8RBA4-ISHNT

Non-disconnect indicating bolt in

8RBA4-INH-B

5RBA8-PNM

5RBA8-GNM

15RBA8-NL

8RBA4-ISHNT

7.2

13.8

13.8

23

34.5

8.3

15.5

15.5

25.5

38

0.5–400E

0.5–400E

0.5–400E

0.5–400E

0.5–300E

0.5–300E

75

95

110

150

150

Disconnect non-indicating

8RBA4-DH

8RBA4-PDM

8RBA4-GDM

15RBA4-DL

8RBA4-ISHNT

Non-disconnect non-indicating

8RBA4-NH

8RBA4-PNM

8RBA4-GNM

15RBA4-NL

8RBA4-ISHNT

Disconnect indicating

8RBA4-IDH

8RBA4-PDM

8RBA4-GDM

15RBA4-DL

8RBA4-ISHNT

Non-disconnect indicating

8RBA4-INH

8RBA4-PNM

8RBA4-GNM

15RBA4-NL

8RBA4-ISHNT

Non-disconnect indicating bolt in

8RBA4-INH-B

8RBA8-PNM

8RBA8-GNM

15RBA8-NL

8RBA4-ISHNT

Disconnect non-indicating

15RBA4-DH

14RBA4-PDM

14RBA4-GDM

15RBA4-DL

15RBA4-ISHNT

Non-disconnect non-indicating

15RBA4-NH

14RBA4-PNM

14RBA4-GNM

15RBA4-NL

15RBA4-ISHNT

Disconnect indicating

15RBA4-IDH

14RBA4-PDM

14RBA4-GDM

15RBA4-DL

15RBA4-ISHNT

Non-disconnect indicating

15RBA4-INH

14RBA4-PNM

14RBA4-GNM

15RBA4-NL

15RBA4-ISHNT

Non-disconnect indicating bolt in

15RBA4-INH-B 14RBA8-PNM

14RBA8-GNM

15RBA8-NL

15RBA4-ISHNT

Disconnect non-indicating

15RBA4-DH

15RBA4-PDM

—

15RBA4-DL

15RBA4-ISHNT

Non-disconnect non-indicating

15RBA4-NH

15RBA4-PNM

—

15RBA4-NL

15RBA4-ISHNT

Disconnect indicating

15RBA4-IDH

15RBA4-PDM

—

15RBA4-DL

15RBA4-ISHNT

Non-disconnect indicating

15RBA4-INH

15RBA4-PNM

—

15RBA4-NL

15RBA4-ISHNT

Non-disconnect indicating bolt in

15RBA4-INH-B 15RBA8-PNM

—

15RBA8-NL

15RBA4-ISHNT

Disconnect non-indicating

25RBA4-DH

25RBA4-PDM

—

38RBA4-DL

25RBA4-ISHNT

Non-disconnect non-indicating

25RBA4-NH

25RBA4-PNM

—

38RBA4-NL

25RBA4-ISHNT

Disconnect indicating

25RBA4-IDH

25RBA4-PDM

—

38RBA4-DL

25RBA4-ISHNT

Non-disconnect indicating

25RBA4-INH

25RBA4-PNM

—

38RBA4-NL

25RBA4-ISHNT

Non-disconnect indicating bolt in

25RBA4-INH-B 25RBA8-PNM

—

38RBA8-NL

25RBA4-ISHNT

Disconnect non-indicating

38RBA4-DH

38RBA4-PDM

—

38RBA4-DL

38RBA4-ISHNT

Non-disconnect non-indicating

38RBA4-NH

38RBA4-PNM

—

38RBA4-NL

38RBA4-ISHNT

Disconnect indicating

38RBA4-IDH

38RBA4-PDM

—

38RBA4-DL

38RBA4-ISHNT

Non-disconnect indicating

38RBA4-INH

38RBA4-PNM

—

38RBA4-NL

38RBA4-ISHNT

Non-disconnect indicating bolt in

38RBA4-INH-B 38RBA8-PNM

—

38RBA8-NL

38RBA4-ISHNT

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-65

2.7
2
2

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

RBA8 Fuse Holders, Mountings and Live Parts

Style

Fuse Holder
Catalog
Number

Mounting
Porcelain
Catalog
Number

Glass Polyester
Catalog
Number

Live Parts
Catalog
Number

Spring and Shunt
Assembly
Catalog
Number

Voltage (kV)
Nominal

Ampere
Maximum Rating

4.8

5.5

450E–720E 60

Non-disconnect indicating bolt in

8RBA8-INH

5RBA8-PNM

5RBA8-GNM

15RBA8-NL

8RBA4-ISHNT

2

7.2

8.3

450E–720E 75

Non-disconnect indicating bolt in

8RBA8-INH

8RBA8-PNM

8RBA8-GNM

15RBA8-NL

8RBA4-ISHNT

13.8

15.5

450E–720E 95

Non-disconnect indicating bolt in

15RBA8-INH

14RBA8-PNM

14RBA8-GNM

15RBA8-NL

15RBA4-ISHNT

2

13.8

15.5

450E–720E 110

Non-disconnect indicating bolt in

15RBA8-INH

15RBA8-PNM

—

15RBA8-NL

15RBA4-ISHNT

23

25.5

450E–754E 150

Non-disconnect indicating bolt in

25RBA8-INH

25RBA8-PNM

—

38RBA8-NL

15RBA4-ISHNT

34.5

38

450E–754E 150

Non-disconnect indicating bolt in

38RBA8-INH

38RBA8-PNM

—

38RBA8-NL

38RBA4-ISHNT

2

2

LIWL
(BIL)

2
2
2
2

RBA4 and RBA8 Exhaust Control Devices

Nominal

Maximum

Ampere Rating

LIWL (BIL)

Style

Exhaust Control
Devices
Catalog
Number

4.8–13.8

5.5–15.5

0.5–720E

—

Condenser (1 pack)

RBA4-COND-1

—

Condenser (3 pack)

RBA4-COND

—

Filter (1 pack)

RBA4-FLTR-1

—

Filter (3 pack)

RBA4-FLTR

—

Condenser (1 pack)

RBA4-COND-1

—

Condenser (3 pack)

RBA4-COND

—

Filter (1 pack)

RBA4-FLTR-1

—

Filter (3 pack)

RBA4-FLTR

—

High capacity filter (3 pack)

RBA4-FLTR-HC-1

—

High capacity filter (1 pack)

RBA4-FLTR-HC

Voltage (kV)

2
2

23–34.5

25.5–38

0.5–540E

2
2
2

13.2

14.4

0.5–720E

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V14-T2-66

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

2.7

RDB2 Outdoor Dropout Fuse Holders, Mounting and Live Parts
Ampere
Rating
10E–200E

10E–200E

10E–200E

10E–200E

Style

Fuse Holder
Catalog Number

Mounting
Vertical
Catalog Number

95

Dropout

8RDB2-DH

8RDB2-VM

8RDB2-UM

RDB2-VL

RDB2-UL

8RDB2-SHNT

110

Dropout

8RDB2-DH

8RDB2-HVM

8RDB2-HUM

RDB2-VL

RDB2-UL

8RDB2-SHNT

110

Dropout

15RDB2-DH

15RDB2-VM

15RDB2-UM

RDB2-VL

RDB2-UL

15RDB2-SHNT

150

Dropout

15RDB2-DH

15RDB2-HVM

15RDB2-HUM

RDB2-VL

RDB2-UL

15RDB2-SHNT

LIWL (BIL)

Underhung
Catalog Number

Live Parts
Vertical
Catalog Number

Underhung
Catalog Number

Spring and
Shunt Assy
Catalog Number

150

Dropout

25RDB2-DH

25RDB2-VM

15RDB2-UM

RDB2-VL

RDB2-UL

25RDB2-SHNT

200

Dropout

25RDB2-DH

25RDB2-HVM

25RDB2-HUM

RDB2-VL

RDB2-UL

25RDB2-SHNT

200

Dropout

38RDB2-DH

38RDB2-VM

38RDB2-UM

RDB2-VL

RDB2-UL

38RDB2-SHNT

250

Dropout

38RDB2-DH

38RDB2-HVM

38RDB2-HUM

RDB2-VL

RDB2-UL

38RDB2-SHNT

Mounting
Style

Vertical
Catalog Number

Underhung
Catalog Number

Vertical
Catalog Number

Underhung
Catalog Number

Spring and
Shunt Assy
Catalog Number

Dropout

8RDB4-DH

8RDB4-VM

8RDB4-UM

RDB4-VL

RDB4-UL

8RDB4-SHNT

Dropout

8RDB4-DH

8RDB4-HVM

8RDB4-HUM

RDB4-VL

RDB4-UL

8RDB4-SHNT

110

Dropout

15RDB4-DH

15RDB4-VM

15RDB4-UM

RDB4-VL

RDB4-UL

15RDB4-SHNT

150

Dropout

15RDB4-DH

15RDB4-HVM

15RDB4-HUM

RDB4-VL

RDB4-UL

15RDB4-SHNT

150

Dropout

25RDB4-DH

25RDB4-VM

25RDB4-UM

RDB4-VL

RDB4-UL

25RDB4-SHNT

200

Dropout

25RDB4-DH

25RDB4-HVM

25RDB4-HUM

RDB4-VL

RDB4-UL

25RDB4-SHNT

200

Dropout

38RDB4-DH

38RDB4-VM

38RDB4-UM

RDB4-VL

RDB4-UL

38RDB4-SHNT

250

Dropout

38RDB4-DH

38RDB4-HVM

38RDB4-HUM

RDB4-VL

RDB4-UL

38RDB4-SHNT

LIWL (BIL)
95
110

0.5–400E

0.5–300E

0.5–300E

Live Parts

Fuse Holder
Catalog Number

0.5–400E

Style

Fuse Holder
Catalog Number

Mounting
Vertical
Catalog Number

Underhung
Catalog Number

Live Parts
Vertical
Catalog Number

Underhung
Catalog Number

Spring and
Shunt Assy
Catalog Number

Dropout

8RDB4-DH

8RDB8-VM

8RDB8-UM

RDB8-VL

RDB8-UL

8RDB4-SHNT

Ampere
Rating

LIWL (BIL)

450E–720E

95
110

Dropout

8RDB4-DH

8RDB8-HVM

8RDB8-HUM

RDB8-VL

RDB8-UL

8RDB4-SHNT

110

Dropout

15RDB4-DH

15RDB8-VM

15RDB8-UM

RDB8-VL

RDB8-UL

15RDB4-SHNT

150

Dropout

15RDB4-DH

15RDB8-HVM

15RDB8-HUM

RDB8-VL

RDB8-UL

15RDB4-SHNT

150

Dropout

25RDB4-DH

25RDB8-VM

25RDB8-UM

RDB8-VL

RDB8-UL

25RDB4-SHNT

200

Dropout

25RDB4-DH

25RDB8-HVM

25RDB8-HUM

RDB8-VL

RDB8-UL

25RDB4-SHNT

200

Dropout

38RDB4-DH

38RDB8-VM

38RDB8-UM

RDB8-VL

RDB8-UL

38RDB4-SHNT

250

Dropout

38RDB4-DH

38RDB8-HVM

38RDB8-HUM

RDB8-VL

RDB8-UL

38RDB4-SHNT

450E–540E

450E–540E

2
2
2
2
2
2
2
2
2
2
2
2
2

RDB8 Outdoor Dropout Fuse Holders, Mounting and Live Parts

450E–720E

2

2

RDB4 Outdoor Dropout Fuse Holders, Mounting and Live Parts
Ampere
Rating

2

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-67

2.7
2
2

RBA/RDB Type Fuses (Including Superseded BA Fuses)

Dimensions
Approximate Dimensions in Inches (mm)
RBA Fuse Mountings—RBA200, RBA400 Disconnect Mounting—4.8 to 34.5 kV

2

0.62 (15.7) Dia. Holes (4)
0.56 (14.2) Dia. Holes (4)

2
2

Expulsion Fuses

1.75
(44.5)

0.75
(19.0)

G
K

C

2

3.56
(90.4)

E

2
2

3.56
(90.4)
D

2

I

A
F

J

2
0.88
(22.4)

2
2

0.75
(19.0)

N

45º Opening
1.75
(44.4)

L

2
2

0.75
(19.0)

0.75
(19.0)

2

Fuse Holder

H

2
2
2

M

B

W—Minimum
Clearance to Ground
R
0.61
(15.5) Fuse Refill

A-20 Insulators Used on 4.8 to 14.4 kV
A-30 Insulators Used on 23.0 and 34.5 kV

2
2
2
2
2
2
2
2
2
2
2
2
V14-T2-68

P

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

2.7

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

Approximate Dimensions in Inches (mm)

2

RBA200, RBA400
Catalog kV
Number BIL

A

B

C

D

E

F

G

H

K

L

M

N

2

P

R

22.62 7.00
7.50
3.50
(574.5) (177.8) (190.5) (89.9)

18.69 18.81 9.25
1.56
(474.7) (477.7) (234.9) (39.6)

10.12 1.64
(257.0) (41.7)

1.50
(38.1)

7.50
3.00
(190.5) (76.2)

7.50
(190.5)

11.50
(292.1)

2

8RBA2 75

18.69 18.81 9.25
1.56
22.62 7.00
10.00 6.00
5.87
14.25 29.69 6.34
(574.5) (177.8) (254.0) (152.4) (149.1) (362.0) (754.1) (161.0) (474.7) (477.7) (234.9) (39.6)

10.12 1.64
(257.0) (41.7)

1.50
(38.1)

7.50
4.00
(190.5) (101.6)

8.50
(215.9)

13.00
(330.2)

2

14RBA2 95

22.62 7.00
10.00 6.00
2.62
(574.5) (177.8) (254.0) (152.4) (66.5)

17.62 32.12 6.34
22.06 22.19 9.25
1.56
(447.5) (815.8) (161.0) (560.3) (563.6) (234.9) (39.6)

10.12 1.64
(257.0) (41.7)

1.50
(38.1)

8.75
6.00
(222.2) (152.4)

11.50
(292.1)

14.50
(368.3)

2

15RBA2 110

22.62 7.00
11.50 7.50
2.62
(574.5) (177.8) (292.1) (190.5) (66.5)

17.62 33.62 7.84
22.06 22.19 9.25
1.56
(447.5) (853.9) (199.1) (560.3) (563.6) (234.9) (39.6)

10.12 1.64
(257.0) (41.7)

1.50
(38.1)

8.75
6.00
(222.2) (152.4)

11.50
(292.1)

16.00
(406.4)

25RBA2 150

33.88 7.00
12.00 10.50 2.50
(860.6) (177.8) (304.8) (254.0) (63.5)

22.25 37.69 11.71 26.69 26.81 9.25
1.56
(565.1) (957.3) (297.4) (677.9) (681.0) (234.9) (39.6)

10.12 1.64
(257.0) (41.7)

1.50
(38.1)

10.50 8.50
(266.7) (215.9)

15.00
(381.0)

20.00
(508.0)

38RBA2 150

33.88 7.00
12.00 10.50 2.50
(860.6) (177.8) (304.8) (254.0) (63.5)

29.25 42.62 11.71 33.69 33.81 9.25
1.56
(742.9) (1082.5) (297.4) (855.7) (858.7) (234.9) (39.6)

10.12 1.64
(257.0) (41.7)

1.50
(38.1)

13.12 12.00
(333.2) (304.8)

19.50
(495.3)

25.00
(635.0)

5RBA4 60

22.25 7.00
7.50
3.50
(565.1) (177.8) (190.5) (89.9)

19.69 20.00 9.25
2.63
(500.1) (508.0) (234.9) (39.6)

11.75 2.17
(298.4) (55.1)

2.20
(55.9)

7.62
3.00
(193.5) (76.2)

7.50
(190.5)

11.75
(292.1)

8RBA4 75

22.25 7.00
10.00 6.00
5.94
13.81 29.90 5.53
19.69 20.00 9.25
2.63
(565.1) (177.8) (254.0) (152.4) (150.9) (350.7) (759.5) (140.5) (500.1) (508.0) (234.9) (39.6)

11.75 2.17
(298.4) (55.1)

2.20
(55.9)

7.62
4.00
(193.5) (101.6)

8.50
(215.9)

13.25
(336.5)

14RBA4 95

22.25 7.00
10.00 6.00
2.56
(565.1) (177.8) (254.0) (152.4) (65.0)

17.19 32.81 5.53
23.69 23.38 9.25
2.63
(436.6) (833.4) (140.5) (601.7) (593.9) (234.9) (39.6)

11.75 2.17
(298.4) (55.1)

2.20
(55.9)

8.88
6.00
(225.6) (152.4)

11.50
(292.1)

14.75
(374.6)

15RBA4 110

22.25 7.00
11.50 7.50
2.56
(565.1) (177.8) (292.1) (190.5) (65.0

17.19 34.31 7.03
23.69 23.38 9.25
2.63
(436.6) (871.5) (178.6) (601.7) (593.9) (234.9) (39.6)

11.75 2.17
(298.4) (55.1)

2.20
(55.9)

8.88
(25.6)

6.00
(152.4)

11.50
(292.1)

16.25
(412.7)

25RBA4 150

33.81 8.00
13.50 10.50 2.50
(858.8) (203.2) (342.9) (254.0) (63.5)

21.81 39.56 9.03
27.69 28.00 9.25
2.63
(554.0) (1004.8) (229.4) (703.3) (711.2) (234.9) (39.6)

11.75 2.17
(298.4) (55.1)

2.20
(55.9)

11.38 8.50
(289.1) (215.9)

15.00
(381.0)

20.25
(514.4)

38RBA4 150

33.81 8.00
13.50 10.50 2.50
(858.8) (203.2) (342.9) (254.0) (63.5)

28.81 44.50 9.03
27.69 35.00 9.25
2.63
(731.8) (1130.3) (229.4) (703.3) (889.0) (234.9) (39.6)

11.75 2.17
(298.4) (55.1)

2.20
(55.9)

13.62 12.00
(356.0) (304.8)

19.50
(4953)

25.25
(641.4)

5.94
13.81 27.40 3.03
(150.9) (350.7) (696.0) (77.0)

J

2

5RBA2 60

5.87
14.25 27.19 3.34
(149.1) (362.0) (690.6) (84.8)

I

W
Recommended
With
With
Phase
Condenser Discharge Spacing 

Note
 Phase-to-phase center spacing, without barriers.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-69

2.7

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

2

Approximate Dimensions in Inches (mm)

2

RBA200, RBA400 and RBA800 (Piggyback Type)—Non-Disconnect Mounting 4.8 to 34.5 kV

2

0.62
(15.7)

H
C

6.12 (155.4)

5.87 (149.1)
1.75
(44.4)

G

2
2

E

G

A

A

2
2

F

F

1.75
(44.4)

2

1.00
(25.4)

2

0.44 (11.2) Dia.
Holes (8)

2

0.66
(16.8)

B

B

1.00
(25.4)

2
2

C

6.00
(152.4)

0.62
(15.7)

4.25
(108.0)

D

5.87 (149.1)

D 6.12 (155.4)

W—Minimum
Clearance to Ground

W—Minimum
Clearance to Ground

2
2
2

K

R

0.41 (11.2) Dia.
Holes (2)

R
J

Fuse Holder RBA200, RBA400

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V14-T2-70

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Fuse Holder RBA800

0.41 (11.2) Dia.
Holes (2)

Expulsion Fuses
RBA/RDB Type Fuses (Including Superseded BA Fuses)

2.7

Approximate Dimensions in Inches (mm)

2

RBA200, RBA400 and RBA800 (Piggyback Type)

2

A

B

C

D

E

F

G

H

J

K

R

W
With
Condenser

60

15.62
(396.7)

4.62
(117.3)

11.43
(290.3)

8.62
(218.9)

15.62
(396.7)

7.50
(190.5)

1.32
(33.5)

7.50
(190.5)

—

18.25
(463.5)

1.64
(41.7)

3.00
(76.2)

7.50
(190.5)

11.16
(283.5)

2

8RBA2

75

15.62
(396.7)

7.12
(180.8)

13.93
(353.8)

8.62
(218.9)

15.62
(396.7)

7.50
(190.5)

1.32
(33.5)

7.50
(190.5)

—

18.25
(463.5)

1.64
(41.7)

4.00
(101.6)

8.50
(215.9)

12.56
(319.0)

2

14RBA2

95

19.00
(482.6)

7.12
(180.8)

13.93
(353.8)

8.62
(218.9)

19.00
(482.6)

7.50
(190.5)

1.32
(33.5)

7.50
(190.5)

—

21.63
(549.4)

1.64
(41.7)

6.00
(152.4)

11.50
(292.1)

13.06
(331.7)

2

15RBA2

110

19.00
(482.6)

8.62
(218.9)

15.43
(391.9)

8.62
(218.9)

19.00
(482.6)

7.50
(190.5)

1.32
(33.5)

7.50
(190.5)

—

21.63
(549.4)

1.64
(41.7)

6.00
(152.4)

11.50
(292.1)

15.56
(395.2)

25RBA2

150

26.43
(671.3)

12.12
(307.8)

18.93
(480.8)

7.25
(184.1)

29.43
(747.5)

8.50
(215.9)

2.50
(63.5)

8.50
(215.9)

—

26.25
(666.7)

1.64
(41.7)

8.50
(215.9)

15.00
(381.0)

19.56
(496.8)

38RBA2

150

33.43
(849.1)

12.12
(307.8)

18.93
(480.8)

7.25
(184.1)

36.43
(925.3)

8.50
(215.9)

2.50
(63.5)

8.50
(215.9)

—

33.25
(844.5)

1.64
(41.7)

12.00
(304.8)

19.50
(495.3)

24.56
(623.8)

5RBA4

60

16.56
(420.6)

4.62
(117.3)

12.31
(312.7)

8.75
(222.2)

16.56
(420.6)

7.50
(190.5)

1.32
(33.5)

7.50
(190.5)

—

19.52
(495.8)

2.17
(55.1)

3.00
(76.2)

7.50
(190.5)

11.16
(283.5)

8RBA4

75

16.56
(420.6)

7.12
(180.8)

14.81
(376.2)

8.75
(222.2)

16.56
(420.6)

7.50
(190.5)

1.32
(33.5)

7.50
(190.5)

—

19.52
(495.8)

2.17
(55.1)

4.00
(101.6)

8.50
(215.9)

12.56
(319.0)

14RBA4

95

19.94
(506.5)

7.12
(180.8)

14.81
(376.2)

8.75
(222.2)

19.94
(506.5)

7.50
(190.5)

1.32
(33.5)

7.50
(190.5)

—

22.90
(581.7)

2.17
(55.1)

6.00
(152.4)

11.50
(292.1)

13.06
(331.7)

15RBA4

110

19.94
(506.5)

8.62
(218.9)

16.31
(414.3)

8.75
(222.2)

19.94
(506.5)

7.50
(190.5)

2.50
(63.5)

7.50
(190.5)

—

22.90
(581.7)

2.17
(55.1)

6.00
(152.4)

11.50
(292.1)

15.56
(395.2)

25RBA4

150

27.37
(695.2)

12.12
(307.8)

19.81
(503.2)

7.37
(187.2)

30.37
(771.4)

8.50
(215.9)

1.32
(33.5)

8.50
(215.9)

—

22.90
(581.7)

2.17
(55.1)

8.50
(215.9)

15.00
(381.0)

19.56
(496.8)

38RBA4

150

34.37
(873.0)

12.12
(307.8)

19.81
(503.2)

7.37
(187.2)

37.37
(949.2)

8.50
(215.9)

2.50
(63.5)

8.50
(215.9)

—

34.52
(876.8)

2.17
(55.1)

12.00
(304.8)

19.50
(495.3)

24.56
(623.8)

5RBA8

60

16.31
(414.3)

4.50
(114.3)

12.85
(326.4)

9.31
(236.5)

17.56
(446.0)

3.50
(88.9)

1.62
(41.1)

3.50
(88.9)

16.31
(414.3)

—

2.17
(55.1)

3.00
(76.2)

7.50
(190.5)

11.00
(279.4)

8RBA8

75

16.31
(414.3)

7.00
(177.8)

15.35
(389.9)

9.31
(236.5)

17.56
(446.0)

6.00
(152.4)

1.62
(41.1)

6.00
(152.4)

16.31
(414.3)

—

2.17
(55.1)

4.00
(101.6)

8.50
(215.9)

12.50
(317.5)

14RBA8

95

19.81
(503.2)

7.00
(177.8)

15.35
(389.9)

9.31
(236.5)

21.06
(534.9)

6.00
(152.4)

1.62
(41.1)

6.00
(152.4)

19.81
(503.2)

—

2.17
(55.1)

6.00
(152.4)

11.50
(292.1)

14.00
(355.6)

15RBA8

110

19.81
(503.2)

8.50
(215.9)

16.85
(428.0)

9.31
(236.5)

21.06
(534.9)

7.50
(190.5)

1.62
(41.1)

7.50
(190.5)

19.81
(503.2)

—

2.17
(55.1)

6.00
(152.4)

11.50
(292.1)

15.50
(393.)

2

25RBA8

150

24.50
(622.3)

11.50
(292.1)

19.85
(504.2)

9.31
(236.5)

27.50
(698.5)

10.50
(266.7)

2.50
(63.5)

10.50
(266.7)

24.50
(622.3)

—

2.17
(55.1)

6.00
(152.4)

15.00
(381.0)

19.50
(4953)

2

38RBA8

150

31.50
(800.1)

11.50
(292.1)

19.85
(504.2)

9.31
(236.5)

34.50
(876.3)

10.50
(266.7)

2.50
(63.5)

10.50
(266.7)

31.50
(800.0)

—

2.17
(55.1)

12.00
(304.8)

19.50
(495.3)

24.50
(622.3)

2

Catalog
Number

kV
BIL

5RBA2

With
Discharge

Recommended
Phase
Spacing 

2

2
2
2
2
2
2
2
2
2
2
2

2

Note
 Phase-to-phase center spacing, without barriers.

2
2
2
2
2
2
2
2
2
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T2-71

Current Limiting Fuses
Eaton Current Limiting Fuses

3.1

Product Overview
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.2

V14-T3-42

V14-T3-50

V14-T3-65

CX, CXI and CXN Type Fuses
V14-T3-67

3
3
3
3
3
3

DSL, MDSL and NPL Type Low Voltage Current Limiters
DSL, MDSL and NPL Type Low Voltage Current Limiters . . . . . . . . . .

3

3

CLT Type Fuses

CX, CXI and CXN Type Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.9

3

3

ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

CLT Type Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.8

V14-T3-19

CLPT and NCLPT Type Fuses

ACLS, BCLS, CLS, HCLS and NCLS Type Fuses . . . . . . . . . . . . . . . . .

3.7

V14-T3-11

CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

CLPT and NCLPT Type Fuses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.6

V14-T3-6

3

CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses . . . . . . . .

3.5

V14-T3-5

Applications
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.4

3
3

Fuse Selection
Fuse Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Current Limiting Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.3

V14-T3-2

V14-T3-76

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-1

3.1
3

Current Limiting Fuses
Product Overview

Contents

Current Limiting Fuses

Description

3

Page

Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interruption and Operation . . . . . . . . . . . . . . . . . . .
Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mountings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3
3

V14-T3-3
V14-T3-3
V14-T3-4
V14-T3-4

3
3
3
3
3
3
3

Product Description

3

Introduction

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Eaton’s medium voltage
fuses provide diverse
characteristics that allow
them to be used in any
application within their
practical range. This
difference is due to the
offering of both expulsion and
current-limiting fuses.
Expulsion and current-limiting
fuses employ different
interrupting techniques that
cause the criteria with which
they are employed to differ.
This requires that a different
set of questions should be
answered when applying
expulsion and current-limiting
fuses. For this reason, and to
avoid confusion, this
application data applies only
to current-limiting fuses. For
information on the application
of expulsion fuses see
Eaton’s Expulsion Fuse
Product Focus.

A backup current-limiting
fuse is able to safely interrupt
all values of fault current from
the rated minimum
interrupting current up to the
rated maximum interrupting
current of the fuse.

Available Types

Generally, Eaton’s backup
current-limiting fuses are the
R-rated range, which have a
rated minimum interrupting
current equivalent to the 100
second current on the
minimum melting timecurrent curve. This point is
not necessarily the limit of
low fault performance,
merely the required limit of
low fault performance, in line
with the normal application
practices for this type of fuse,

Current ANSI/IEEE fuse
standards define three types
of current-limiting fuses:
back-up fuses, generalpurpose fuses and full-range
fuses. It is important for the
user to have an
understanding of these
definitions to ensure proper
application of the fuse.

3
V14-T3-2

Although only backup current
limiting fuses make a specific
reference to a rated minimum
interrupting current, generalpurpose and full-range define
a rated minimum interrupting
current in different terms.
The rated minimum
interrupting current of a
general-purpose fuse is the
current that causes the fuse
to operate in one hour, and
the rated minimum
interrupting current of a fullrange fuse is the minimum
value of current that will melt
the fusible element(s) under
specified conditions.

which is used for high fault
protection of medium voltage
motor starters in conjunction
with relays and overload
contactors.
Eaton’s R-rated backup fuses
may be thermally damaged or
may not operate correctly if
subjected to overload
currents greater than those
shown on the safe overload
curves and the rated
minimum interrupting current
for long times.
A general-purpose currentlimiting fuse is able to safely
interrupt all values of fault
current from the current that
causes the fuse to operate in
one hour or more up to the
rated maximum Interrupting
current of the fuse.
The one hour melting time is
with the fuse in a
conventional mount, and in a
25˚C ambient. Other
mountings or ambient
conditions may cause the
fuse to melt earlier, but this
does not alter this rated
minimum interrupting
current. Eaton’s general
purpose current-limiting
fuses are used to protect
circuits feeding transformers
and feeders, where there is
downstream protection that
will operate before the
medium voltage general-

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

purpose fuse is affected by a
long term overload. See
application notes on feeder
and transformer protection
for details. Eaton’s E-rated
general-purpose fuses may
be thermally damaged or may
not operate correctly if
subjected to overload
currents greater than those
shown on the safe overload
curves and the indicated one
hour interrupting current for
long times.
A full-range current-limiting
fuse is able to safely interrupt
all values of fault from the
minimum value of current
that will melt the fusible
element up to the rated
maximum interrupting
current under specified
conditions.
Eaton’s full range currentlimiting fuses are used to
protect circuits feeding
transformers and feeders,
where there may not be any
effective downstream
protection.

Current Limiting Fuses
Product Overview

Construction

Interruption and Operation

Current-limiting fuses are
sometimes referred to as
silver-sand fuses. This
reference comes from the
fact that calibrated pure silver
current responsive elements
are surrounded by pure silica
or quartz sand with controlled
grain size that acts as a
cooling and absorbing agent
when the fuse interrupts a
fault. Interruption of a fault by
a current-limiting fuse is quiet
and completely self
contained. In general, pure
silver is used for the
elements in Eaton current
limiting fuses because it
provides the ideal mix of
physical characteristics. With
uniquely designed element
constructions for each class,
these current limiting fuses
offer the highest available
ratings in the smallest barrel
sizes. All components are
housed in a fiberglass
reinforced resin tube with
plated copper contact caps
that are magna-formed onto
the housing for optimum
strength and filled with high
purity silica sand. Blown fuse
indication is provided by
either a striker pin or a pop-up
button. A durable nameplate
label provides rating and
manufacturer information.

Current limiting fuses operate
in two modes, depending on
the magnitude of the fault
current. The first is operation
in the overload mode where
the fault current is below the
threshold current for the
fuse. In this mode, the fuse
does not operate during the
first major half cycle, and
does not limit the magnitude
of the fault current. The
second is operation in the
short-circuit or currentlimiting mode where the
current is above the threshold
current for the fuse. In this
mode, the fuse does operate
during the first major half
cycle, and does limit the
magnitude of the fault
current.
There is a small overlap zone
between the overload and
short-circuit modes of
operation, where the fuse
may or may not act in the
current-limiting mode. The
performance of the fuse in
this zone is dependent on
circuit conditions such as the
power-factor of the circuit,
and the point on wave of the
inception of the fault. The
threshold value for any
particular fuse can be read off
the peak let-through (cut-off
current) chart. The threshold
current is the value of
available current in amperes
on the horizontal axis that
corresponds to the intercept
of the individual fuse line and
the peak asymmetrical
available diagonal line.

3.1
3

In the overload mode, the
fuse does not limit the peak
value of the current, as in this
mode, it carries one or more
full half cycles of current
before the current responsive
element(s) melt open. After
the current responsive
element(s) melt open, they
will arc until they have burnt
back far enough to interrupt
the overload current and
withstand the circuit recovery
voltage.

3
3
3
3
3
3

In the short-circuit mode, the
fuse element(s) melt almost
instantaneously, producing a
number of series arcs at the
neck points on the elements.
The interaction of these
series arcs and the
constraining medium
(typically sand) introduces a
rapidly rising resistance into
the fault circuit that limits the
peak value of the current to a
value considerably less than
the peak value of the
prospective current wave.
The stored energy in the
circuit causes current to
continue to flow through the
fuse until it is dissipated and
this produces a high arc
voltage across the fuse. The
fuse changes a high current
low power factor circuit into a
lower current, higher power
factor circuit, and as a result,
the current is forced to near
zero well before the natural
current zero of the circuit.
Because the current is forced
to zero before the natural
current zero of the circuit, the
effects of transient recovery
voltage of the circuit are
reduced because the current
and voltage are nearly in
phase. Current–limiting fuses
are thus relatively insensitive
to the transient recovery
voltage.

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-T3-3

3.1
3

Current Limiting Fuses
Product Overview

CL Fuse Operation

3
3
3
3

Element melts forming multiple series arcs at element necks

3
3
3
3

Heat from arcing melts the sand into a glass-like structure referred to
as “fulgurite”

3
3
3
3
3

Fulgurite absorbs the heat from the arcs but also encloses them,
depressing current peak value

3

Application

Mountings

Eaton offers a wide range of
interrupting ratings in single
barrel designs with ratings
extended to higher currents
in double, triple and quad
barrel designs. E-rated fuses
are available in both long
(CLE) and short (HLE) clip
center designs. BHLE and
HCL versions are available for
bolt-in and clamp in mounting
arrangements. R-rated motor
starter fuses for standard clip
mounting (CLS), are also
available with an integral
hookeye for Eaton’s
Ampgard™ starter
assemblies (ACLS) or bolt-in
style mounting (BCLS). CLPT
fuses are available for
potential transformer
protection in several different
diameters. CX and CLT fuses
are ideally suited for canister
applications and available in a
wide range of ratings. Low
voltage current limiters,
MDSL for Magnum and DSL
breakers and NPL for
network protectors, which
are not covered in this
catalog, are also available in a
variety of current ratings.

Eaton’s current-limiting fuses
are available in industrystandard mounting sizes.
Disconnect and nondisconnect mountings are
available for most fuse case
sizes. Mountings include the
base, porcelain or glass
polyester insulators and live
parts. Live parts, fuse clips
and fuse end fittings are also
available separately. All
Eaton’s current-limiting fuses
and mountings are easy to
install and operate.

3
3
3
3
3
3
3
3
3
3
3

Arc is extinguished as current is forced to zero

Because of the limitation of
the peak value of the current,
and the early extinction of the
current, the energy let
through by the fuse in the
short-circuit mode is
considerably lower then the
energy that would have been
let through by the unaltered
prospective current wave.
This significantly reduces
energy let through and can
protect the circuit from
mechanical and thermal
damage that would be
caused in the absence of the
current-limiting fuse.

Eaton’s current-limiting fuses
produce arc voltages that are
within the limits specified in
the applicable C37 standards.
The arc voltage is seen on the
supply side of the fuse, but is
not normally seen on the
load-side of the fuse.

3
3
3
3
V14-T3-4

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current Limiting Fuses
Fuse Selection

Current Limiting Fuses

3.2

Contents
Description
Fuse Selection
Current Limiting Applications . . . . . . . . . . . . . . . . .
Voltage Rating . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupting Rating. . . . . . . . . . . . . . . . . . . . . . .
Continuous Current Rating . . . . . . . . . . . . . . . .
Fuse Enclosure Packages . . . . . . . . . . . . . . . . .
Parallel Fuses . . . . . . . . . . . . . . . . . . . . . . . . . .
Coordination . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interchangeability . . . . . . . . . . . . . . . . . . . . . . .
Specific Applications . . . . . . . . . . . . . . . . . . . . .
Let-Through Current . . . . . . . . . . . . . . . . . . . . .
Fuses and Lightning Arresters . . . . . . . . . . . . .

Page

3
3

V14-T3-6
V14-T3-6
V14-T3-6
V14-T3-7
V14-T3-8
V14-T3-8
V14-T3-8
V14-T3-9
V14-T3-9
V14-T3-10
V14-T3-10

3
3
3
3
3
3
3
3
3

Fuse Selection
There are four major
considerations involved in the
selection of a current limiting
fuse. The first three
considerations are the
voltage rating, the
interrupting rating and the
continuous current rating of
the fuse. Proper attention
should be given to each of
these considerations as
improper application in any
one area may result in the
fuse failing to perform its
intended function. The fourth
consideration is coordination
with line and load side
protective equipment that is
needed to give selectivity of
outage and to prevent
premature fuse operation.
Each of the four areas is
discussed here individually.

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-T3-5

3.2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Fuse Selection

Current Limiting Applications
Voltage Rating

Interrupting Rating

The rated maximum power
frequency voltage of a
current-limiting fuse is the
maximum rms value of circuit
voltage at which the fuse has
been demonstrated to be
able to operate with specified
circuit fault conditions. A fuse
must not be applied at any
location where the circuit
voltage exceeds the rated
maximum power frequency
voltage of the fuse.

It is good practice that if more
than one phase of the system
is extended beyond the fuse
location, the fuse maximum
design voltage should equal
or exceed the system
maximum line-to-line voltage
regardless of how the threephase system is grounded on
the source side of the fuse or
how the transformers or
loads are connected on the
load side of the fuse.

Voltage ratings of particular
fuse types are listed in the
appropriate fuse data sheets.

It is a common practice,
however, to choose to fuse
wye grounded wye
transformers on the primary
side with fuses with a voltage
rating that only exceeds the
system line-to-neutral
voltage. In most cases this
presents no problems but the
user should be aware of the
remote possibility of a
secondary phase-to-phase
ungrounded fault that could
impose full line-to-line voltage
across the fuse.

The first rule regarding fuse
application is that the fuse
selected must have a
maximum design voltage
rating equal to or greater than
the maximum power
frequency voltage that will be
available in the system in
which the fuse is installed
under all possible conditions.
In most cases this means the
maximum design voltage of
the fuse must equal or
exceed the system maximum
line-to-line voltage. The only
exception to this rule occurs
in distribution systems when
fusing single-phase loads
connected from line-toneutral on a four-wire
effectively grounded system.
Here the fuse maximum
design voltage need only
exceed the system maximum
line-to-neutral voltage
providing it is impossible
under all fault conditions for
the fuse to experience the full
line-to-line voltage. When
only one phase of a four-wire
effectively grounded system
is extended beyond the fuse
to supply a single-phase load
connected from phase-toneutral, it is acceptable to
have the fuse maximum
design voltage equal or
exceed the system maximum
line-to-neutral voltage.

3
3

The interrupting action of
current limiting fuses
produces arc voltages that
can exceed the system
voltage. Care must be taken
to ensure that these arc
voltages do not exceed the
insulation level of the system.
If the fuse voltage rating is
not permitted to exceed 140
percent of the system
voltage, the arc voltages will
generally not create
problems. This 140 percent
limit on the voltage rating
over system voltage does not
restrict the use of a higher
rated fuse if the system has a
high enough insulation level
to withstand the short time
application of the arc voltage.
Eaton’s current limiting fuses
are designed so that the arc
voltage peak at rated
interrupting current is less
than three times that of the
nominal voltage rating. If the
system can withstand this
peak the higher rated fuse
may be used.

Probably the most common
problem created by high arc
voltages is the sparking over
of lightning arresters. As this
is a common problem, it is
discussed in detail in the
section Fuses and Lightning
Arresters.
It should be remembered that
in most cases the fuse
voltage rating should not
exceed the system voltage
by more than 40% and under
no circumstances may the
system voltage exceed the
maximum design voltage
rating of the fuse. The
altitude at which a currentlimiting fuse is applied must
also be considered. The
dielectric strength of air
decreases with increases in
altitude, necessitating a
modification to the voltage
rating above 1000m.
Altitude correction factors
are listed in Annex B of
IEEE Std. C37™.100.1.

In general, current-limiting
fuses are not sensitive to
higher levels of interrupting
current. Interrupting ratings
are normally based on market
requirements and economic
cost or availability of testing
facilities.
Interrupting ratings of
particular fuse types are listed
in the appropriate fuse data
sheets.

1.7
1.6
1.5
1.4
1.3
1.2
1.1

1

2

3
3
V14-T3-6

The rated maximum
interrupting current of a
current-limiting fuse is the
rms value of the symmetrical
AC component of the highest
current that the fuse has
been demonstrated to be
able to successfully interrupt
under any possible condition
of asymmetry with specified
circuit conditions. A fuse
must not be applied at any
location where the available
fault current exceeds the
rated maximum interrupting
current of the fuse.

Asymmetry Factors

Asymmetry Factor at 1/2 Cycle

3

Current Limiting Fuses

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3

4

5

10
20
Circuit X/R Ratio

30 40 50

Current Limiting Fuses
Fuse Selection

Historically, current limiting
fuses had been assigned
asymmetrical interrupting
ratings and MVA interrupting
ratings. Compliance with the
test requirements in IEEE
Std. C37.41™-2000 for
current limiting fuses ensures
that Eaton’s fuses are tested
under peak asymmetry
conditions. Fuses are not
constant kVA devices; if the
circuit voltage is reduced, the
interrupting capacity is not
increased. The kVA
interrupting rating is reduced
if the fuse is applied at a
lower value of circuit voltage.
The peak asymmetry factor in
the first half cycle is a
function of the circuit X/R
ratio of the circuit, and the
relationship is shown on
Page V14-T3-6. The
theoretical maximum value of
the asymmetry factor in a
purely inductive circuit would
be 1.732. However, with the
X/R values encountered in
power circuits, the factor is
rarely more than 1.6.
In the past, fuses were
sometimes rated by nominal
three-phase kVA ratings. The
nominal three-phase kVA
rating was calculated by the
formula kVA = I x kV x 1.732,
where I is the rated
maximum interrupting
current in symmetrical rms
amperes and kV is the
nominal fuse voltage rating.
When a current-limiting fuse
interrupts a fault current
above its threshold current, it
will limit the amplitude of the
current in the first major loop.
The level of current limitation,
measured by the ratio of peak
circuit available current to the
fuse peak let-through current
increases as the value of
symmetrical available current
increases above the fuse
threshold current. In addition
to controlling the amplitude
of the let-through current, a
current-limiting fuse can also
cause the current to be
extinguished significantly
earlier than the natural
current zero of the circuit.

The altitude at which a
current-limiting fuse is
applied must also be
considered. The dielectric
strength of air decreases with
increases in altitude,
necessitating a reduced
interrupting rating above
1000m (3280 ft).
Altitude correction factors
are listed in Annex B of
IEEE Std. C37.100.1™.
A general purpose current
limiting fuse can have some
limits on interrupting low
currents. General purpose
fuses are fault protective but
not overload protective. They
do not provide protection for
values of overload current in
the range of one to two times
the fuse continuous current
rating.
A back-up current limiting
fuse only protects against
high values of fault current,
and must be applied with
another series protective
device. For lower values of
fault current, below the
minimum interrupting current
of the fuse, the series
protective device must
interrupt these lower values
of fault current.

Continuous Current Rating
Eaton current limiting fuses
have been demonstrated to
be able to carry their rated
current continuously without
exceeding the temperature
rise values permitted by
C37.40.
Continuous current ratings of
particular fuse types are
listed in the appropriate fuse
data sheets.
Eaton current-limiting fuses
have A-, C-, E-, R-, X- or dual
E/X-ratings.
An A-rating indicates that the
value before the A is the rated
continuous current of the fuse.
A C-rating indicates that the
value before the C is the rated
continuous current of the
fuse, and that the calibrated
current-responsive element
will melt in 1000 seconds at
an rms current within the
range of 170 to 240% of the
rated continuous current.

The C-requirement is
specified in ANSI C37.47™.
An E-rating (100E or less)
indicates that the value
before the E is the rated
continuous current of the
fuse, and that the calibrated
current-responsive element
will melt in 300 seconds at an
rms current within the range
of 200 to 240% of the rated
continuous current.
An E-rating (greater than
100E) indicates that the value
before the A is the rated
continuous current of the
fuse, and that the calibrated
current-responsive element
will melt in 600 seconds at an
rms current within the range
of 220 to 264% of the rated
continuous current.
The E-requirements are
specified in ANSI C37.46.
Some Heritage
Westinghouse CLE fuses
were assigned an X-rating
that indicates that the value
before the X was the rated
continuous current of the
fuse, but the fuse design did
not satisfy the Erequirements specified
above. Other Heritage
Westinghouse CLE fuses
were assigned dual E- and Xratings, where the lower
value satisfied the Erequirements above, but the
fuse could also carry a higher
value of continuous current
without exceeding the
temperature rise values
permitted by C37.40, the
X-rating.
An R-rated fuse has current
responsive elements
calibrated to melt between
15 and 35 seconds when
subjected to a current of 100
times the R value. These
fuses also have temperature
rise requirements at specific
values of current.
The R-requirement is
specified in ANSI C37.46.
E- and X-rated fuses are
power class fuses, used in
transformer and feeder
circuits.

R-rated fuses are power class
fuses, and are used
specifically in medium
voltage motor controllers.
C-rated fuses are distribution
class fuses, and are used
mainly in transformer circuits.
A-rated fuses can be
distribution or power class
fuses.

3
3
3
3
3

An E- or C-rating only define
one gate on the time-current
curve of the fuse, and does
not imply interchangeability
between fuses from different
manufacturers.

3

There are also significant
differences between the
time-current curves of E-rated
current-limiting and E-rated
expulsion fuses, both in the
low overcurrent and high fault
current areas. E-ratings for
expulsion fuses generally
give a 2:1 ratio of minimum
melting current to continuous
current rating. However,
E-ratings for current-limiting
fuses generally give a 1.6 to
1.8 ratio of minimum melting
current to continuous current
rating.

3

If the fuse is subjected to a
current below the 330, 600,
or 1000 second melting
current as stated in the E or C
fuse definitions, but
substantially above the
continuous current rating of
the fuse for an excessive
length of time, a large
amount of heat is generated
and this may cause damage
to the fuse, adversely
affecting the fuse integrity or
changing the time-current
characteristics of the fuse.
Specific allowable overload
characteristics for generalpurpose and full-range
current-limiting fuses must
not be exceeded under any
circumstances. If back-up
fuses are properly applied
with a suitable low current
protection device to clear low
fault currents, overloads
should not present a
problem.

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.2

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

V14-T3-7

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Current Limiting Fuses
Fuse Selection

In practice, current-limiting
fuses are used to protect
circuits feeding transformers,
motors and other equipment
where overloads and inrush
currents are common.
Current-limiting fuses have a
rather low thermal capacity
and cannot carry overloads of
the same magnitude and
duration as transformers and
motors of equal continuous
current rating. For this
reason, a general fuse
application ratio of 1.4:1 fuse
continuous current rating to
full load current is suggested
so the fuse will not operate
on acceptable overloads and
inrush conditions. This is a
general figure for typical
applications and that a ratio
as low as 1:1 can be used if
the system current will never
exceed the rated current of
the fuse.

rating of the fuse. When an
Eaton fuse is to be used
within an enclosure, be sure
to check with the
manufacturer of that
enclosure and use the
suggested current rating or
apply the suggested derating
factor if one is necessary.

In other applications, a higher
ratio will be required to
prevent the fuse from
operating on transformer
inrush or motor starting
current or from being
damaged due to severe
overloading. More specific
application information can be
found in the individual
application sections that
follow.

In addition to selecting a fuse
that meets the voltage,
interrupting and continuous
current requirements for the
application, it is also
important to ensure that the
melting and clearing
performance of the fuse
protects and coordinates
adequately with other circuit
components. Eaton publishes
minimum melt and total clear
time-current characteristics,
and minimum melting and
total clearing I2t values to
assist with this coordination.
The minimum melt curve
gives the minimum melting
time in seconds of the fusible
element(s) at a particular
value of symmetrical rms
current under specified
temperature conditions and
without pre-loading. The total
clearing curve gives the
maximum clearing time in
seconds to complete
interruption of the circuit at a
particular value of
symmetrical current under
specified conditions. The
range between the minimum
melting and the total clearing
time current curves includes
an allowance for
manufacturing tolerances,
and the arcing time of the
fuse after melting. Arcing
time is time in seconds
lapsing from the melting of
the fusible element(s) to the

Under no circumstances
must the fuse continuous
current rating be less than
continuous load current and
that E- and C-rated fuses may
not provide protection for
currents in the range of one
to two times the continuous
current rating.

Fuse Enclosure Packages
It is quite common for
current-limiting fuses to be
mounted in a fuse enclosure
package such as a switch in
an enclosure that is
surrounded by air, or a
transformer draw-out well
that is mounted in the
transformer and surrounded
by hot oil. Fuse enclosure
package classes are defined
in ANSI C37.40.
Due to the elevated ambient
temperature produced by
these enclosure packages, it
is sometimes necessary to
derate the continuous current

V14-T3-8

Parallel Fuses
At times it is desirable to
have a continuous current
rating larger than any single
fuse barrel can provide.
Higher ratings can be
obtained by paralleling fuses.
Two, three and four barrel
designs are available. Consult
Eaton for specific guidance.
Under no circumstances
should fuses be paralleled
unless the paralleling is one
of the extensively tested
Eaton designs.

Coordination

to ensure the current does
not exceed the fuse overload
characteristics. If back-up
fuses are used, ensure that
another device that will clear
fault currents below the
minimum interrupting current
of the fuse is used.

final interruption of the
circuit. The minimum melting
and total clearing I2t values
indicate fuse and circuit
damage energy values and
are used only for fault
currents that melt the fuse
elements in less than 0.1
second, that is, above the
threshold value for the fuse.

Proper coordination of
current-limiting fuses in the
overload mode is ensured by
keeping the fuse minimum
melting curve above the total
clearing curve of any
downstream overcurrent
protective device, and
keeping the fuse total
clearing curve beneath the
minimum operating curve of
any upstream protective
equipment. Coordination in
the short-circuit zone is
achieved by simply using the
I2t values, and keeping the
minimum melting I2t of the
fuse above the total clearing
I2t of any downstream
protective device, and
keeping the total clearing I2t
of the fuse beneath the
damage value of the
upstream equipment.

As previously mentioned,
three types of current-limiting
fuses are defined in ANSI/
IEEE standards. Full-range
fuses will interrupt any value
of current from the
interrupting rating down to
that which will cause the
element(s) to melt under
specified conditions. Generalpurpose fuses will interrupt
any value of current from the
interrupting rating down to a
current that will melt the
element(s) in one hour under
specified conditions. Back-up
fuses will interrupt any
current from the interrupting
rating down to the rated
minimum interrupting
current. When coordinating
using a full-range or generalpurpose fuse, it is necessary
Allowable Overload Factors
A

B

C

Y

Z

Hours
2
1.5
1
1/2

Above
100A

100A

Sec. or Less

1000

X

W

600
300
200
100

Average
Melting
Curves
1

Average
Melting
Curves
2

Average
Melting
Curves

1
2 3 4
1
2 3 4
x 100% of Fuse Rating
W = E rated general purpose type fuse 100A or less except 15.5 kV CLE
X = E rated general purpose type fuse above 100A except 15.5 kV CLE
Y = C rated general purpose type fuse
Z = General purpose fuse CLE 15.5 kV pnly

3 4

Effects of Ambient Temperature on Melting Curves
Melting Time in Percent
of Time Shown on TimeCurrent Characterist Curve

3.2

130
120
Silver

110

Tin

100
90
80
70
-40

-30

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

-20

-10

0

10

20

30

40

50

60

3.2

Current Limiting Fuses
Fuse Selection

Pre-Loading Adjustment Factors for Power Fuses

Interchangeability

3
3
3
3
3

100

3
Fuses Above 100A

3

50

3

Fuses 100A and Less
C-Rated Fuses
0

0

3

50
100
150
200
Load Current in Percent of Fuse Ampere Rating

250
P

3
3

Typical Fuse Coordination

C

B

1000
800
600

A

Minimum
Melt
Total
Clearing

CLE-1
200E

A

1000 kVA
480V
DS-416
1200 LSI

B

C

C

LD LD
Breaker Amps PU T

SD SD

I

PU T

PU

DS-416

1200 1.0x 12 sec 7x 0.33 sec 10

DS-206

400

1.0x 36 sec — —

3
3

40

3

20

3

10
8
6
4

3

0.4

3

0.2

3

0.02

10

6000
8000
10000

4000

2000

600
800
1000

400

3
3

0.01
40
60
80
100

3

1
0.8
0.6

0.04

Scale x 10 = Secondary Current In Amperes

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

200

0.1
0.08
0.06

200

C

3

2

DS-206
400 LI

3

400

100
80
60

4.8 kV

Specific Applications
There are aspects to be
considered other than voltage
rating, interrupting rating and
continuous current rating.
One concerns the types of
current-limiting fuses: fullrange fuses, general-purpose
fuses and back-up fuses. Fullrange and general-purpose
fuses are normally applied
without supplementary
protection in the medium
voltage system. These fuses
are used on transformer and
feeder applications. Generalpurpose fuses are used in
power transformer circuits
where secondary side
protective devices will clear
secondary faults. Full-range
fuses are used in distribution
transformer circuits where

3

3

F

C-, E- and R-ratings define the
performance of a fuse at one
particular point on the timecurrent curve, However, the
fuse performance at other
values of current are shown
by each manufacturer’s
published time-current
curves. Since these curves
are a function of the
distinctive current responsive
elements used by each
manufacturer, fuses with the
same C-, E- or R-ratings from
different manufacturers may
not be interchangeable in all
applications. Users must also
be aware that E-rated current
limiting type and E-rated
expulsion type fuses have
very different time-current
and short circuit
characteristics. It is the
responsibility of the user to
ensure that the physical
dimensions and electrical
characteristics of the fuse are
appropriate for the particular
application in the intended
equipment.

20

The lower right curve gives
an example of a properly
coordinated fuse application.
The figure shows a generalpurpose CLE fuse protecting
the primary of a 1000 kVA
transformer with Eaton’s type

Coordination with reclosing
circuit breakers may be
performed with the aid of the
proper coordination chart.
This type of curve is
explained in the repetitive
faults section of the
application data.

specified minimum
interrupting rating. An
example of a properly applied
medium-voltage back-up
current-limiting fuse is in a
motor starter unit where the
CLS fuse is used in series
with a relay and contactor to
protect it from faults that
exceed the contactor rating.

there may not be protection
on the secondary side of the
transformer and the primary
fuse may be called upon to
clear a secondary system
fault. A back-up fuse must
have another medium voltage
protective device so that it
will not be called upon to
interrupt currents below its

Time In Seconds

If desired or if unusual
conditions exist, shifts in the
time-current curve due to
ambient temperature and
preloading may be examined
individually. Eaton’s timecurrent characteristics are
derived from tests on fuses
surrounded by freely
circulating air at an ambient
temperature of 25˚C and with
no initial preloading as
specified in C37.40. Fuses
subjected to conditions other
than the above will
experience shifts in the timecurrent curves. The upper
right curve gives the
adjusting factors for changes
in ambient temperature and
also the adjusting factors for
preloaded fuses. These
adjusting factors are valid
only for Eaton’s power fuses.

DS or Magnum low voltage
air circuit breakers protecting
the secondary equipment.

Melting Time in Percent
of Time Shown on TimeCurrent Characterist Curve

Time-current curves for
Eaton’s current-limiting fuses
are based on standard
conditions of temperature
and altitude, and the zone
between the minimum
melting and total clearing
characteristics allows for
manufacturing tolerances.
Preloading and elevated
ambient temperatures are not
allowed for. It is
recommended that a safety
zone be used when applying
current-limiting fuses to
ensure that proper
coordination is maintained to
allow for these factors. There
are two approaches used to
achieve this safety zone and
both produce similar results.
One approach employs a
25% safety zone in time for a
given value of current and the
other uses a 10% safety zone
in current for a given value of
time. Eaton uses the second
method as it allows the
safety zone to be published
on the left-hand side of all the
time-current curves.
Coordination is then achieved
by overlaying curves and
shifting one by the width of
the published safety zone.

3
3
3
3
3

V14-T3-9

3.2
3
3
3
3
3
3
3
3
3
3

Current Limiting Fuses
Fuse Selection

Let-Through Current
An important feature of
current-limiting fuses is the
limitation of fault current and
energy seen by the system
being protected. Although a
current-limiting fuse is not
current-limiting for values of
fault current below the
threshold current of the fuse,
these lower values of fault
currents do not present
problems due to the low
energy. For currents equal to
or greater than its threshold
current, the fuse will limit the
current let-through to the
system. The value of this letthrough current is dependent
on the particular fuse type,
the magnitude of the fault
current and the timing of the
fault initiation—the power

factor of the circuit only has a
minimal effect.
If the timing of the fault is
such that fuse melts after the
current has crested, the fuse
will not limit the peak current
because the peak has already
passed. With a fully
asymmetrical fault, the
available current would have
crested in 1/4 cycle.
However, the presence of
the fuse in the circuit will limit
the peak value of current, and
have caused the current to
have peaked before the 1/4
cycle time. Thus, the currentlimiting action varies with the
degree of asymmetry of the
fault.

3
Typical Peak Let-Through Current Curves
100
80
60

3

1
0.8
0.6

3

Available Current In Amperes

3
3

60000
80000
100000

3

2

40000

3

4

20000

3

50
40

6000
8000
10000

3

125
100
80
65

10
8
6

4000

3

20

2000

3

Fuses and Lightning Arresters
450
400
350
300
250
200
175
150

40

400

3

Peak Instantaneous Let-Through Current
In Kilo-Amperes

3

600
800
1000

3

Eaton publishes let-through
curves that are based on power
circuits with an X/R ratio greater
than 15. The curve below
shows a typical let-through
curve. The horizontal axis gives
the rms symmetrical available
fault and the vertical axis the
peak instantaneous let-through
current. Let-through current for
any particular fuse may be
found by choosing the curve for
the fuse in question and reading
the let-through for any given
value of available fault. The point
where the curve intersects the
asymmetrical available peak line
is the threshold current (for that
fuse) or that point where the
fuse first become current
limiting. Curves like this are
found in Eaton’s current-limiting
fuse application data and make
it easy to check the fuse letthrough against the withstand of
the equipment it is protecting.
Current-limiting fuses generate
arc voltages that are higher than
the system power frequency
voltages. The magnitude of arc
voltage generated is dependent
on the element design, element
length, and the type and size of
filler. A strip type element, for
example, generates arc voltages
that are more dependent on the
system voltage, whereas a
uniform cross section wire
element produces arc voltages
dependent on the fault current
value. Users of current-limiting
fuses are not generally aware of
the fuse design so a general
estimation of generated arc
voltage is needed. Eaton’s
current-limiting fuses perform
their function by generating arc
voltages that may peak as high
as three times the nominal
voltage rating of the fuse at its
interrupting rating.
When applying current-limiting
fuses, care should be taken to
see that arc voltages produced
by the fuse do not exceed the
insulation level of the system.
An examination of the insulation
level of the system will show
that lightning arresters are the
principal equipment to check. If
arc voltages cause
interconnected lightning
arresters to operate, a relatively
high current would be shunted

3
3
3
3
3
3
V14-T3-10

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

into arresters that are not
designed for such interrupting
duty.
This problem could be
eliminated by mounting the fuse
on the line side of the arrester,
but this is not always practical.
Many utilities prefer to apply the
fuse on the load side of the
arrester to eliminate possible
fuse damage that might result
from lightning. Other utilities
employ transformers with
bushing mounted currentlimiting fuses where the fuse
must be installed on the load
side of the arrester.
For current-limiting fuse applied
on the load side of a distribution
arrester, arc voltages do not
affect the arrester if the fuse
and the arrester have the same
voltage rating; however, if an
arrester on the line side has a
voltage rating lower than that of
the fuse, it may sparkover.
Under this condition the arrester
and the fuse will share the
current. Distribution type
arresters have higher
impedances that keep them
from experiencing excessive
amounts of current and they are
not usually damaged.
Intermediate and station type
arresters on the other hand
have lower impedances that
allow them to experience higher
currents and they may become
damaged. Therefore, station
and line type arresters should
not be applied on the line side or
in parallel with current-limiting
fuses unless their sparkover
value is greater than the
maximum arc voltage the fuse
can produce.
Machine protection arresters
are purposely designed to have
low sparkover values. They
should, however, be connected
directly to the machine
terminals and not on the line
side of the fuse. If properly
connected, the fuse arc voltage
can have no effect on them.
Correctly applied distribution
class lightning arresters found
on the line side of the fuse have
sparkover values sufficiently
high to remain unaffected by
fuse operations.

Current Limiting Fuses
Applications

3.3

Contents

CLPT Fuses

Description

Page

Applications
Potential and Control Transformer
Application . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor Protection . . . . . . . . . . . . . . . . . . . . . . . .
Repetitive Faults . . . . . . . . . . . . . . . . . . . . . . . .

3
3

V14-T3-16
V14-T3-16
V14-T3-17

3
3
3
3
3
3
3
3
3

Applications

3

Transformer Applications
Fuses are installed on the
primary side of a transformer
to:
●

●

●

Protect the system on the
source side of the fuses
from an outage due to
faults in or beyond the
transformer (isolate a
faulted transformer from
an otherwise healthy
distribution system to
prevent further
disturbance). In the case of
an internal winding fault in
the transformer, the fuse
should prevent further
collateral damage to the
transformer and its
surroundings. Currentlimiting fuses are generally
better able to limit internal
damage to the transformer
than expulsion fuses
Coordinate with protection
on the low voltage side of
the transformer
(transformer primary
protection must be
overload tolerant, allowing
the secondary protection
to clear faults occurring
downstream of the
secondary protection)
Protect the transformer
against bolted secondary
faults (the fuse should
operate on any bolted
secondary faults between
the transformer secondary
terminals and the

●

secondary protection
before the transformer is
damaged)
Protect the transformer
against higher impedance
secondary faults to
whatever extent is
possible (the fuse should
limit damage to the
transformer windings to
the best extent possible)

Selecting the proper voltage
and interrupting ratings for
the fuse is straightforward
and has been sufficiently
covered in their respective
sections.
There are two sometimes
conflicting factors when
selecting a fuse to protect a
transformer circuit. The
continuous current rating
must be large enough to
prevent premature fuse
interruption from magnetizing
or inrush currents and it must
also be large enough to
prevent fuse deterioration or
fuse interruption during
normal or emergency
overload situations. The fuse
continuous current rating
must also be small enough to
provide the protection listed
in the purpose hierarchy. In
practice, it is not always
possible to select a fuse large
enough to allow for all the
overloading required and still

provide complete protection
for the transformer. In these
cases, the user should decide
how the priorities lie and
trade off overloading ability
for transformer protection.
Fuses on the primary side of
transformers should not
operate on transformer
magnetizing inrush current.
The magnitude of the first
loop of inrush current and the
rate at which the peaks of
subsequent loops decay is a
function of many factors.
Some of these are
transformer design, residual
flux in the core at the instant
of energization, the point on
the voltage wave at which
the transformer is energized,
and the characteristics of the
source supplying the
transformer. When
energizing, the heating effect
of the inrush current in a fuse
can be considered equal to 12
times the transformer full
load current flowing for 1/10
of a second. Thus, when
selecting the current rating
for fuses used at the primary
side of a transformer, the
fuse minimum-melting curve
must lie above and to the
right of the point on the timecurrent curve corresponding
to 12 times full load current
and 0.1 second. The fuse
whose minimum melting

Volume 14—Fuses

www.comoso.com

curve lies just above and to
the right of this point is the
lowest rated fuse that can be
used at the primary terminals
to satisfy the inrush
requirements. This criterion is
often satisfied for all Eaton’s
fuses if the fuse current
rating is equal to or greater
than the transformer selfcooled full load current.
System operators frequently
overload their transformers
for short periods of time
during normal and emergency
situations. To allow this
flexibility, it is necessary to
select a fuse that can carry
the overload without being
deteriorating.

CA08100016E—August 2011 www.eaton.com

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

V14-T3-11

3.3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Current Limiting Fuses
Applications

To accommodate these
overloads, a fusing ratio
higher than 1:1 is almost
always required when
applying fuses for
transformer protection. The
fuse emergency overload
curve (Page V14-T3-8) and
the required extent of
overloading is used to
determine the smallest fuse
that can be applied.
Determine the minimum fuse
rating by using the duration
(ordinate) of the transformer
overload on the fuse overload
curve (Page V14-T3-8) to
obtain a the multiple of
current rating that should not
be exceeded. Divide the
transformer overload current
by the multiple obtained from
the overload curve—the
result is the minimum fuse
current rating. Select the fuse
with a continuous current
rating that equals or is just
larger than this value. The
allowable time duration of the
current in the primary side
fuses during transformer
overload should never exceed
the values shown by the
fuse overload curve on Page
V14-T3-8.
Note: Short term and long term
overloading of transformers will
adversely affect the service life of
the transformer. Also, increasing
the primary fuse size to allow for
higher overloads decreases the
protection afforded the
transformer. The extent to which
transformers are overload, and
the implications for system
security are economic decisions
that are taken by the system
operator.

3
3
3
3

Suggested minimum fuse
sizes for protection of selfcooled transformers are
given in the table on Page
V14-T3-15. These tables are
based on the premise that
the maximum 1.5 hour
overload on the transformer
would not exceed 200
percent of the transformer
rating. This overload condition
requires that the minimum
ratio of fuse current rating to
transformer full load
current is 1.4:1. Fuse sizes
listed in the table on Page
V14-T3-15 are those that are
just higher than 1.4 times the
transformer full load current.
If higher or longer duration
transformer overloads are to
be permitted, a fuse with a
higher continuous current
rating may be required. The
procedure described above
should then be used to find
the smallest permissible fuse
size.
If provisions are made by
thermal or other protective
devices to limit transformer
overloads to a lower range,
the ratio of fuse current to
transformer full load current
can be less than 1.4:1. To find
the amount of reduction
permissible without damage
to the fuse, the procedure
using the overload curve
should be used.

When the transformer has
forced cooling, the minimum
fuse size that can be applied
that be based on the
transformer top rating and
the extent to which the
transformer will be
overloaded beyond the top
rating.
It should be remembered that
E-rated current limiting fuses
applied at the primary
terminals of a transformer
might not provide protection
for currents between one and
two times the continuous
current rating of the fuse.
That is, for currents in this
range that exceed the time
limits shown by the fuse
overload curve on Page
V14-T3-8 under the heading
“Coordination”. Fuses
subjected to such overloads
may suffer from undetectable
deterioration before the
fusible element melts. In
order to provide dependable
overload protection for the
transformer, protection must
be applied on the secondary
side of the transformer.
Equal concern should be
given to the upper limit of
continuous current rating that
will provide protection for the
transformer. The extent to
which the fuses are to
protect the transformer
against secondary faults is
one of several factors that
determines the upper limit.
When a main secondary
breaker is not used, the
primary fuses may be the
only devices that provide
thru-fault protection for the
transformer. In these
circumstances the fuse
should operate before the
transformer windings are
damaged due to the heavy
currents. The capability of
transformer windings to carry

3
3
3
3
3
V14-T3-12

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

these thru-fault or heavy
currents varies from one
transformer design to
another. When specific
information applicable to
individual transformers is not
available, the transformer
heat curves given on Page
V14-T3-14 can be used to
evaluate the thru-fault
protection offered the
transformer by the fuses. The
curve labeled N=1 is drawn
through the points defined in
IEEE/ANSI Appendix C57.92,
Section 92-06.200 such that
the curve has the same
shape as shown in Figure 1 of
IEEE publication 273 titled,
Guide for Protective Relay
Application to Power
Transformers. This curve
applies to single-phase
transformers and to threephase faults on three phase
transformer banks. Curves for
values of N other than 1 apply
to unsymmetrical faults on
three-phase transformers and
three-phase transformer
banks that have at least one
delta-connected winding.
Ideally, the total clearing
time-current of the primary
fuse would lie below the heat
curve for all values of current
up to 25 times the
transformer rated current.
However, this is not usually
possible as the fuse has
minimum limitations placed
on the rating due to long time
overload impressed on the
transformer and the fact that
E-rated expulsion fuses do
not provide protection for
currents below two times
their continuous current
rating. In spite of these lower
limitations, primary side fuses
should protect the
transformer for bolted
secondary faults and higher
impedance secondary faults
to whatever extent is
possible.

Current Limiting Fuses
Applications

The relationship between rated
line (fuse) current and rated
winding current (referred to,
as the “base current of the
winding” in IEEE/ANSI Std.
C57™.12.00 is 1 for wye
connected primaries and is 1/ 3
for delta-connected primaries.
IEEE/ANSI Std. C57™.12.00
also indicates that the
transformer winding shall be
capable of withstanding 25
times rating winding current for
two seconds and smaller
multiples of rated winding
current for longer periods of
time. However, transformer
overloads and faults are
generally expressed in terms of
line and not winding current.
This could present a problem for
fault conditions where the type
of fault changes the relationship
between the line and winding
current (see the table below)
gives a multiplier that will
translate the line current in
multiples of the winding current
for different type faults for
various transformer windings.
This table leads us back to the
transformer heat curves shown
on Page V14-T3-14 where it
can be verified that the curve
N=1 passes through the point
25 times full load line current
and two seconds. The curves
for other than N=1 are for
unsymmetrical faults as can be
seen from the table below.

Wye connected transformers
tied to the system neutral or
floating have line currents
that are equal to the winding
currents for faults external to
the transformer, regardless of
whether the neutral is or is
not grounded. Thus a fuse
connected to the terminal of
a wye-connected winding will
see the same current that is
in the winding for all faults
external to the transformer.
Also, there is a simple
relation between the primary
and secondary amperes,
whether load or fault currents
are being considered.
This is not the case when the
transformer has a deltaconnected winding, either on
the primary or secondary side
of the transformer. With
delta-connected primary
windings, the current in the
lines (fuses) supplying the
delta winding and currents in
the primary delta windings
generally are not equal, and
of greater importance the
ratio of line (fuse) current to
winding current varies with
the type of fault on the
external system. With delta
connected secondary
windings, the current in the
transformer secondary
windings is generally not
equal to the secondary line
current, and the ratio of
primary line current to the
secondary line current varies
with the type of fault on the
secondary system.

3.3

Coordination diagrams employ
the transformer heat curves and
fuse time-current curves to
determine which fuse rating
may be safely applied. These
diagrams are the tools used to
apply the information previously
cited. The most straight-forward
diagram involves fuses applied
at the terminals of transformers
with wye primary windings. The
table below shows that the
fuse current is the same as the
winding current for all faults
external to the transformer. This
means the coordination diagram
consists simply of the direct
reading of the fuse time-current
curves and the transformer heat
curve N=1 for coordination
diagrams where the abscissa is
labeled in amperes in the
primary system. To coordinate
with the abscissa labeled in
secondary amperes, the same
two curves are shifted to allow
for the ratio between primary
and secondary amperes.

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Multiples of Primary Line Current for Fixed Secondary Winding Current
Transformer Connection
All Neutrals Grounded
Primary
Secondary

3

N
(N Times Secondary Winding Current Gives Multiples of Primary Line Current)
Three-Phase Fault
Phase-to-Ground Fault
Phase-to-Phase Fault

3

1
1
1

3

1
1

3

…
1

1/ 3

—

…

3

2/ 3

3

3/2

3
3
3
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-13

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Current Limiting Fuses
Applications

When fuses are employed at
the terminals of a delta-wye
transformer, the coordination
diagram becomes a bit more
involved. In this instance the
table on Page V14-T3-13
shows that the fuse current
varies in relation to the
winding current depending on
the nature of the fault. Thus,
when the coordination is with
respect to primary amperes,
the diagram consists of one
direct reading fuse timecurrent curve and one or more
transformer heat curves. The
number of heat curves
included would be determined
by the types of secondary
faults considered. The table
on Page V14-T3-13 gives the
N curve to be used for the
different faults to be
considered. When the
coordination is with respect to
secondary amperes, the
diagram consists of one
transformer heating curve (N=1)
and up to three fuse timecurrent curves. The three timecurrent curves are again
dependent on the possible
faults to be considered. The
table on Page V14-T3-13
shows that after the curve is
translated to secondary
amperes it must be shifted one
over the square root of 3 when
phase-to-earth faults are
considered and two over the
square root of 3 when phase-tophase faults are considered to
obtain proper coordination.

3
3
3
3

Regardless of whether a
primary or secondary current
abscissa is employed, a
coordination diagram for a deltawye transformer shows that the
primary side fuses do not
protect the transformer for highimpedance secondary faults and
overloads. This type of
protection can be obtained
through the application of
secondary side breakers. If a
secondary breaker were used it
would be added to the
coordination diagram by plotting
the breaker phase and ground
trip characteristics. Selective
coordination would exist if the
breaker phase trip characteristic
curve lies below the fuse
characteristic for a phase-tophase fault and the heating
curve, and the breaker ground
trip characteristic for a single
line-to-ground fault and the
heating curve.
The proceeding pertains to
diagrams using secondary
amperes. If the breaker
characteristic is to be
translated to primary
amperes, its characteristics
must lie beneath the fuse
characteristic and the heating
curve for N=1. For
unsymmetrical faults, the
breaker characteristic shifts
by the same multiple as the
heating curve.
If further secondary
protection is translated to the
primary, the characteristic
must lie beneath the
secondary breaker
characteristic for the different
types of faults considered.

Fuses used at the terminals of a
delta-delta transformer require:
1. Fuse time-current.
2. Heating curves if both
three-phase and phase-tophase faults are to be
considered.
This agrees with information
presented in the table on Page
V14-T3-13. When the abscissa
is in primary amperes, the
curves are read directly. An
abscissa in secondary amperes
uses the same curves but shifts
them from primary to secondary
amperes.

For all the coordination diagrams
just discussed, the vertical
distance between the total
clearing curve and the safe heat
curve indicates the margin of
protection offered for different
types of faults. It should be
remembered, however, that the
transformer heat curves
illustrated in this application data
are drawn from the reference
previously cited and they may
not apply to all transformer
designs.

Typical Transformer Heat Curves
10000
8000
6000
4000

2000

1000
800
600
400

200

100
80
60
N=2A/ 3

40
Time in Seconds

3.3

N=1
20

N= 3/2

10
8

N=1/ 3

6
4

3
3

2

3

Transformer
Full Load

Adjusted
Heat Curves

Inrush Current

0.6 0.8 1
2
4 6 8 10
20
40 60 80 100
Line Current in Multiples of Transformer Full Load (Rated) Line Current

3
3
3
3
V14-T3-14

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.3

Current Limiting Fuses
Applications

Suggested Minimum Current Limiting Fuse Current Ratings

3

Self-Cooled 2.4–15.5 kV Power Transformer Applications
System
Nominal kV 2.4
Fuse
Maximum kV 2.75
Full
Transformer Load
kVA Rating
Current
Self-Cooled Amps

Fuse
Rating
Amps
E or C

3

4.16

4.8

7.2

12.0

13.2

13.8

14.4

5.5
Full
Load
Current
Amps

Fuse
Rating
Amps
E or C

5.5
Full
Load
Current
Amps

Fuse
Rating
Amps
E or C

8.3
Full
Load
Current
Amps

Fuse
Rating
Amps
E or C

15.5
Full
Load
Current
Amps

Fuse
Rating
Amps
E or C

15.5
Full
Load
Current
Amps

Fuse
Rating
Amps
E or C

15.5
Full
Load
Current
Amps

Fuse
Rating
Amps
E or C

15.5
Full
Load
Current
Amps

Fuse
Rating
Amps
E or C

0.4

1E

0.4

1E

0.4

1E

3

Three-Phase Transformers
9

2.2

5E

1.3

3E

1.1

3E

0.7

3E/3.5C

0.4

1E

15

3.6

15E

2.1

3E

1.8

3E

1.2

3E/3.5C

0.7

1E

0.7

1E

0.6

1E

0.6

1E

30

7.2

15E

4.2

10

3.6

5E

2.4

4.5C/5E

1.4

3E/4C

1.3

3E/4C

1.3

1E/4C

1.2

3E/4C

45

10.8

15E/18C

6.2

10

5.4

10

3.6

5E/6C

2.2

4C/5E

2

3C/5E

1.9

3E/4E

1.8

3E/4E

75

18

25

10.4

15

9

15E/18C

6

10

3.6

6C/10E

3.3

5E/6C

3.1

5E/6C

3

5E/6C

112.5

27

40E/45C

15.6

25

13.6

20

9

15

5.4

8C/10E

5

8C/10E

4.7

8C/10E

4.5

8C/10E

150

36

50

20.8

30

18

25

12

18C/20E

7.2

10

6.6

10

6.2

10

6

10

225

54

75C/80E

31.3

45C/50E

27.2

40

18

25

10.8

15

9.9

15

9.4

15

9

15

300

72

100

41.6

60C/65E

36

50

24

35C/40E

14.4

25

13.1

20

12.5

18C/20E

12

18C/20E

500

120

200E

69.4

100

60

100E

40

60C/65E

24.1

40

21.9

30

21

30

20

30

3
3
3
3
3
3
3
3
3

750

180

250E

104

150E

90

125E

60

100

36.1

60C/65E

32.8

45C/50E

31

45C/50E

30.1

45C/50E

1000

241

350E

140

200E

120

200E

80

125

48.1

75C/80E

43.7

60C/55E

42

60C/65E

40.1

60C/65E

1500

360

600E

208

300E

180

250E

120

200

72.2

100

65.6

100

62

100

60.1

100

3

2000

481

750E

278

400E

241

350E

160

250

96.2

150

87.5

125E/
150C

84

125E/
150C

80.2

125E/
150C

3

2500

600

1100E

346

600E

301

450E

200

350E

120

200E

109

175

104

175

100

175

3
3

Single-Phase Transformers
5

2.1

5E

1.2

3E

1

1.5E

0.7

3E/3.5C

0.4

1E

0.4

1E

0.4

1E

0.4

1E

10

4.2

15E

2.4

5E

2.1

3E

1.4

3E/3.5C

0.8

1.5E

0.8

1.5E

0.7

1E

0.7

1E

15

6.3

15E

3.6

5E

3.1

5E

2.1

3E/3.5C

1.3

3E/4C

1.1

3E/4C

1.1

3E/4C

1.1

3E/4C

25

10.4

15E

6

10

5.2

10

3.5

5E/6C

2.1

3E/4C

1.9

3E/4C

1.8

3E/4C

1.7

3E/4C

37.5

15.6

25

9

15E/18C

7.8

12C/15E

5.2

8C/10E

3.1

5E/6C

2.8

4C/5E

2.7

4C/5E

2.6

4C/5E

50

20.8

30E/35D

12

20

10.4

15

7

10

4.2

8C/10E

3.8

8C/10E

3.6

8C/10E

3.5

5E/6C

75

31.3

45C/50E

18

25

15.6

25

10.4

15

6.3

10

5.7

8C/10E

5.4

8C/10E

5.2

8C/10E

100

41.7

60C/65E

24

40

20.8

30

13.9

20

8.3

12C/15E

7.6

12C/15E

7.2

12C/15E

6.9

10

167

70

100

40

50

35

50

23.2

40

13.9

20

12.7

18C/20E

12.1

18C/20E

11.6

18C/20E

250

104

150E

60

100E

52.1

80E

34.8

50E/60C

20.8

30

19

30

18.1

30

17.4

30

333

139

200E

80

125E

69.5

100E

46.3

65E/100C 27.7

40

25.2

40

24.1

40

23.1

40

500

208

300E

120

200E

104

150E

39.6

100

41.6

60

38

60C/65E

36.2

60C/65E

34.7

60C/65E

667

278

400E

160

250E

139

200E

92.6

150

55.4

85C/100E 50.5

75C/80E

48.2

75C/80E

46.3

75C/80E

883

347

600E

200

350E

173

250E

115.5

200

69.4

100

63.5

100

60.4

85C/100E 57.8

85C/100E

1250

521

750E

300

450E

260

400E

174

250

104

175

95

150

90.6

150

125E/
150C

86.8

3
3
3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-15

3.3

Current Limiting Fuses
Applications

3

Potential and Control
Transformer Application

3

CLPT (CLE-PT) and (N)CLPT
type fuses provide protection
for the systems to which
potential and control power
transformers are connected.
Like other fuses, (N)CLPT
fuses must meet all of the
basic selection requirements
but there are a couple of
differences in the application
that will be mentioned here.

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Instrument potential
transformer fuses are
selected on the basis of the
transformer magnetizing
inrush current instead of the
full load current rating. To
prevent unnecessary fuse
operation, the fuses must
have sufficient inrush
capacity to safely pass the
magnetizing current inrush of
the transformer. Fuses
should be selected on the
basis of the smallest current
rating whose minimum
melting time-current
relationship lies above and to
the right of the inrush value.
In some applications these
types of transformers are
operated in a wye connection
at 0.557 times their normal
rated voltage. (N)CLPT fuses
will usually protect the
transformer when applied at
this reduced voltage but if the
short circuit is through long
leads or if the primary voltage
is materially decreased by the
short circuit on the
secondary, the short-circuit
current may not be sufficient
to operate the fuses.

3
3
3

Motor Protection
Medium voltage motor
starters are used to protect
medium voltage motor
circuits. These starters use
overload relays, contactors
and back-up current-limiting
fuses to provide complete
overcurrent protection. The
fuses operate to interrupt
high values of fault current
that exceed the interrupting
rating of the contactor and
the overload relay operates to
open the contactor before the
fuse operates for lesser, yet
abnormal, currents due to
motor overloads, locked
rotor, repeated starts,
extended accelerating time or
low value fault currents. To
obtain this coordination, the
proper combination of fuse,
contactor, current
transformer and overload
relay must be used to ensure
that the contactor operates
within its ratings and the fuse
for those values of fault
current that exceed the
contactor’s rating.
Responsibility for this
coordination rests with the
manufacturer of the motor
starter. In choosing suitable
components, the following
four areas of protection must
be considered:
1. Protection of the motor
against sustained
overloads and locked
rotor conditions by
means of the overload
relays and contactor;
2. Protection of the fuses
against sustained
currents above the fuse
continuous current
ratings and yet below
their minimum
interrupting value by
means of overload relays
and contactor;

3. Protection of the circuit
by means of the overload
relays and contactor for
currents within the
interrupting limits of the
contactor where it is
more economic for the
contactor to operate
rather than the fuses;
and
4. Protection of the circuit,
contactor, overload
relays and current
transformers from
damaging effects of
maximum fault currents
by means of properly
sized back-up currentlimiting fuses that
restrict the let-through
currents on high current
faults to tolerable levels.
The fuses are not protecting
the motor itself; they are
protecting the system from
faults in the motor and motor
control circuit.
When selecting a fuse for
such a coordinated motor
starter scheme, the basic
requirements for the fuse in
addition to those of adequate
voltage and interrupting rating
are:
1. The fuse continuous
current rating must be
equal to or greater than
the full load current of
the motor;
2. The fuse must have the
capacity to carry
continuously, without
damage, currents less
than the pick-up value of
the overload relay, but no
less than 125% of the
motor full load current;
and

3
3
3
3
3
3
V14-T3-16

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3. The fuse must have the
capacity to carry, without
damage, currents greater
than the pick-up value of
the overload relay but
less than the fuse melt
and relay overload
setting curves for
sufficient time to allow
the overload relay to
operate.
4. The fuse must be
selected to allow for the
run-up time of the motor,
and also for the
frequency of starts. It is
typical also to select
fuses to allow for two
consecutive starts.
This is the reason for
emphasizing the need to
avoid damage to the fuse
from long duration overloads
such as those caused by
locked rotor conditions.
Damage can generally be
avoided by keeping the
melting curve of the fuse
above the locked rotor
current by a safe margin until
it is intersected by the relay
curve. A reasonable margin is
10% but the manufacturer’s
application instructions will
state just how close an
application is permissible.

Current Limiting Fuses
Applications

Typical Fuse and Motor Starter Coordination

ensure the fuse is capable of
withstanding these frequent
and severe heating and
cooling cycles. The test
consisted of running 2000A
through a 24R fuse for 10
seconds, then 400A for 5
minutes and finally cooling
the fuse with no current for 5
minutes. This three-step
cycle was repeated 3000
times with the fuse showing
no deterioration as measured
by change in resistance at the
conclusion.

4160V

Current
Limiting Fuse
Contractor
Thermal
Overload

CT

Motor
1000

Locked Rotor
Amperes = 600

To aid in selecting a fuse for
motor starter application, the
following may prove helpful:

Overload Relay
100% of Locked
Rotor Amperes = 660
100

FullLoad
Amperes = 160
125% of Full Load
Amperes = 200

10
Time in Seconds

Full load current =
(horsepower).(746)/
[(voltage).(3^.5).(efficiency).
(PF)
For general use, a 0.9 for
efficiency and a 0.8 for power
factor yield the following
simple relationship between
full load current and
horsepower:

Starting Time
for Motor
Fuse Melting
Curve

1

Full load current =
(horsepower).(0.701)/(kV)
Again on a general basis,
inrush current may be
assumed to be six times the
full load current for a duration
of 15 seconds.

Fuse Total
Clearing
Curve

Repetitive Faults

0.1

0.01
100

1000
Current in Amperes

Although it is possible to
protect a medium voltage
motor circuit with a generalpurpose or full-range fuse
without a series relay-contactor
combination, it is not a
common practice for two
reasons. First, the melting
current of the fuse is
approximately twice its rated
current. This means that the
fuse does not provide
protection against anything less
than 100% overload, and
usually this range is even larger.
Second, the damage
characteristics of the apparatus
and the total clearing time-

10000

current characteristic of the
fuse hardly ever coincide. Thus
a motor protected only by a
general-purpose or full-range
fuse may be exposed to
overloads of somewhat longer
duration than desirable or the
fuse may limit the equipment’s
overload capacity.
As should be obvious, the
duty of fuses in motor starter
circuits is characterized by
the frequent application of
high overloads such as motor
starting currents and cooling
periods while the motor is
off. Eaton’s CLS fuse has
been thoroughly tested to

It is often desired to determine
the performance of fuses
under repetitive faults such as
produced by the operation of
reclosing circuit breakers. This
performance is becoming of
increasing interest as a result
of the increased application of
current limiting fuses on pole
type transformers. The
performance is determined by
graphically simulating the
fuse’s heating and cooling
characteristics that are found
in and expressed by the
melting time-current curves.
Conventional E- and C-rated
fuses can with good
approximation be regarded as
bodies whose heating and
cooling properties are
described by the basic
exponential Curves A and B as
shown in Page V14-T3-18.
Except for being inverted, the
cooling curve is the same as
the heating curve as both have

the same time constant. Each
fuse has a specific time
constant that can be calculated
with sufficient accuracy by the
formula 0 = 0.1 S2 where S is
the melting current at 0.1
second divided by the melting
current at 300,600 or 1000
seconds. The 300 seconds
applies for fuses rated 100E
amperes or less, the 600
seconds for fuses rated above
100E amperes, and the 1000
seconds for C-rated fuses.
The time constant of a
specific fuse, having been
obtained in terms of seconds,
gives a specific time scale to
the general heating and
cooling curves of Page
V14-T3-18. It enables plotting
the course of the fuse
temperature (in percent
values) if the sequence and
duration of the open and
closed periods of the recloser
are known. This is illustrated
by curve C that is formed by
piecing together the proper
sections of Curves A and B.
Next the temperature at
which the fuse will melt must
be determined. Refer to the
standard time-current curves
and find the melting time M
for a specific value of fault
current. The melting
temperature Tm lies where
the ordinate to the time M
intersects curve A. It is not
necessary to know the
absolute value of this
temperature as it is sufficient
to know its relation to the
peaks. A similar temperature
Tn can be found using the
total clearing time for the
specific fault current. The
results are two temperatures
where any time the fuse
curve C intersects line Tm the
fuse could operate and any
time it intersects line Tn the
fuse will definitely operate.
The gap between Tm and Tn
indicates the tolerance range
as set forth in ANSI and
NEMA standards where Eand C-rated fuses are
defined.

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
V14-T3-17

3.3
3

Current Limiting Fuses
Applications

Temperature Cycle of a Fuse During Reclosing Operation

Reclosing Circuit Breaker Fuse Coordination

N
100%

M
.75M

2

1

3
3
3
3
3
3
3
3
3
3
3
3
3

Percent Temperature Rise T%

3

3

Tr

4

Percent Temperature Rise T%

3

A
80%
Tn
60%

Tm
Ts

40%
C

100
80
60
40

p1
p2
Unit Time
Constant

1

2
3
Relative Time t/

4
t = Time in Seconds
= Time Constant
of Fuse

Curve A–Basic fuse heating curve: Tf (I-e t/ )
Curve B–Basic fuse cooling curve: Tf x e t/ )
Curve C–Temperature rise curve of fuse subjected to reclosing cycle
M–Melting time of fuse at a given fault current
N–Total clearing time of fuse at same fault current
Tm, Tn–Levels of melting temperature of fastest and of slowest fuse
(See note below)
Ts–Safe temperature level, considering service variables
Tf–Hypothetical steady-state temperature level (100%) attained if the
fuse element did not open when melting temperature was reached
but continued to be a resistance of constant value
Note: The absolute temperature at which the elements of the fastest
and of the slowest fuse melt is the same since both fuses are made
of the same material, However, Tn and Tm are different if measured
by the final temperature level if reached at a given current.

Heating

C

10
8
6
4

B
Cooling

2

P-4
0.5

1.5

If the fuse is not to operate,
curve C must remain below
the level Tm by a safe margin.
It is common practice to
provide such a safety margin
by coordinating the breaker
with a fuse curve whose time
ordinates are 75 percent of
those of the melting curve.
Line Ts represents this
temperature as shown.

3
3
3
3
3
3
3
3
3
3
3
3
3
3
V14-T3-18

1

P-5
2
2.5
Relative Time t/

3

t = Time in Seconds
= Time Constant of Fuse
Notes: Recloser data: 400PR (cycling code A1-3CH3).
Fuse type and rating: CLT (drawout) 8.3 kV 150°C.
Fuse speed ration, S-2150/420 = 5.11.
Thermal time constant, = 0.10 S2, 2.61 seconds.
Fault current 1350A.

B
0

A

20

1
20%

QMMN

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Although the construction of
the temperature diagram as
outlined above basically
offers no difficulties, the
manipulation is made easier
and more accurate by putting
the graph on semi-logarithmic
coordinates as shown. On
these coordinates, the
cooling curve B becomes a
straight line.

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

3.4

Contents

E-Rated Power Fuses

Description

Page

CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses
Catalog Number Selection. . . . . . . . . . . . . . . . .
V14-T3-21
Ratings and Selection . . . . . . . . . . . . . . . . . . . .
V14-T3-21
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
V14-T3-24
CLE Type . . . . . . . . . . . . . . . . . . . . . . . . . . .
V14-T3-24
HLE Type . . . . . . . . . . . . . . . . . . . . . . . . . . .
V14-T3-28
LHLE Type . . . . . . . . . . . . . . . . . . . . . . . . . .
V14-T3-31
AHLE Type . . . . . . . . . . . . . . . . . . . . . . . . . .
V14-T3-32
BHLE Type . . . . . . . . . . . . . . . . . . . . . . . . . .
V14-T3-33
HCL Type . . . . . . . . . . . . . . . . . . . . . . . . . . .
V14-T3-36
Mounting Details . . . . . . . . . . . . . . . . . . . . . . . .
V14-T3-38

3
3
3
3
3
3
3
3
3
3
3

CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses
Product Description

Applications

Features

Eaton offers a wide range of
interrupting ratings in single
barrel designs with ratings
extended to higher currents
in double, triple and quad
barrel designs. E-rated fuses
are available in both long
(CLE), intermediate (LHLE)
and short (HLE) clip center
designs.

Helix type (helical element
configuration, current
limiting) and Heritage CLE
type medium voltage fuses
are general purpose, indoor
fuses designed to provide
both high and low level fault
protection. Helix fuses may
be applied wherever it is
necessary to limit shortcircuit currents on high
capacity systems.

Helix Type Fuses
Helix type current limiting
fuses, designed for indoor
and outdoor applications, are
replaceable fuse units with
automatic blown fuse
indication provided by a
striker pin. In addition to
giving local indication of fuse
condition, the striker pin can
be used to trigger an external
tripping device. The powerful
striker pin delivers
approximately three joules of
energy over a 5/8-inch travel
distance, more than sufficient
for mechanical operation of
trip-all-phase devices or
micro-switches. HLE and CLE
type fuses can be mounted in
disconnect or non-disconnect
mounting configurations.
BHLE type fuses can be
directly “bolted-in” onto
switchgear bus bars. HCL
type fuse units are mounted
in cam action clip-lock clips
for easy installation and
replacement.

CLE fuses conform to
dimensional standards
established in the past by
Westinghouse when the
original BAL current limiting
power fuses for transformer
and general feeder
applications were introduced.
HLE fuses conform to later,
shorter dimensional
standards.

Because of their general
purpose, current limiting
characteristics, these types
of fuses are well suited for a
wide variety of distribution
systems and consumer
applications. Some of the
more frequent possibilities
are:
●

BHLE fuses are identical to
HLE fuses with the addition
of “bolt-in” mounting blades.

●
●

HCL fuses are special
dimension fuses for “bolt-in”
and “clip-lock” mounting
blades.

Power transformer
protection
Fused switches
Feeder circuit
sectionalization

3
Helix fuses have a semicoreless design, enclosed in
high strength, filament
wound glass and epoxy
tubes. They are filled with
high purity silica sand of
controlled grain size. Fuse
elements are pure silver in a
double helix configuration to
optimize performance by
maximizing the number of
elements.
The double helix design
delivers:
●
●
●

●
●

Higher current ratings
Cooler operation
Improved time-current
characteristics
Reduced 12t let-through
Shorter length

Single, double and triple
barrel designs are available to
cover a wide range of current,
voltage and interrupting
ratings. For their sizes,
Eaton’s helix type fuses offer
the highest available Eratings.
In addition, Eaton’s 3-inch
diameter fuses will directly
replace other manufacturer's
fuses.

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-19

3.4
3
3
3
3
3
3
3
3
3
3
3
3
3

CLE and HLE Features
Helix type current limiting
fuses offer a number of
advantages over competing
current limiting designs.
During the selection process,
consider the following:
●

3
●

3
3
●

3
3
3
3
3

●

●

●

The Heritage fuse designs
are suitable for indoor use
only.

3

3

CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

Heritage Type Fuses
Certain “Heritage”
Westinghouse fuse types
have been retained where
there are no suitable helix
type fuses to replace them.
These fuses are normally only
supplied for replacement
purposes. The major items
here are the shorter 2-inch
diameter 2.75 kV CLE fuses
from 15E to 25E and 15.5 kV
fuses where the older
designs used more parallel
barrels than the current Helix
design.

3

3

Current Limiting Fuses

●

Optimized Energy
Exchange: The double
concentric helix
configuration (inner and
outer) optimizes energy
exchange by making more
efficient use of the sand
filler
Improved Arc Control:
The double helix design
has more elements for
more surface area
permitting better arc
control
Lower Temperature Rise:
Heat radiation with the
HLE design is excellent
resulting in lower normal
operating temperatures
Promotes Faster Melting:
Under overload conditions,
thermal transfer from the
inner helix is reduced by a
modified temperature
gradient leading to faster
melting

Blown Fuse Indication:
Blown fuse striker pin will
protrude from the top of
the fuse providing a visual
indication of operation, as
well as a triggering means
for external devices
Interchangeability: Helix
type fuses are
mechanically
interchangeable and in
many cases have higher
maximum current ratings
than competing current
limiting fuses
Limited Arc Voltage:
Improved limited arc
voltage on 40E and higher
current rating fuses
permits 15.5 kV fuses to
be used on 8.3 kV circuits
and 8.3 kV fuses to be
used on 5.5 kV circuits

Helix type current limiting
fuses also offer additional
advantages over other types
of fuse designs:
●

●

●

●

Quiet and Safe
Operation: Helix type
fuses are sealed static
units eliminating the need
for externally mounted
exhaust control devices
Limits Fault Current: By
design, helix type fuses
interrupt high fault currents
before the first loop of fault
current reaches its natural
crest value. The double
helix design delivers lower
I2 t
Higher Interrupting
Capabilities: Helix type
fuses have higher
interrupting ratings than
expulsion fuses because of
their current limiting
capabilities
Indoor/Outdoor
Application: Helix type
fuse end caps are
magneformed to the tube
and sealed with resilient
RTV sealant

Mounting Hardware
●
CLE type and HLE helix
type current limiting fuses
are designed to be used in
either disconnect or nondisconnect mountings
●
All CLE and HLE fuse units
can be mounted, as
supplied, in appropriate
non-disconnect mountings.
Adding disconnect fuse
end fittings to a CLE or
HLE fuse unit permits it to
be mounted in an
appropriate disconnect
mounting
●
Most HCL current limiting
fuse units have blades to
enable the fuse to be
mounted in cam locking
clips
●
HCL5-900E and 750E, and
BHLE fuses have end
blades for direct bolting to
custom bus bars or
mountings
●
AHLE and certain Heritage
designs are specifically
equipped for mounting in
Eaton’s Ampgard motor
starter equipment
●
Disconnect and nondisconnect live parts above
the insulator are available
for CLE, HLE and HCL cliplock fuses

3
3
3
3
3
V14-T3-20

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

3.4

Catalog Number Selection

3
3

Helix Fuse Units

15 (B) CLE - 100 E (- D)
Maximum kV
2 = 2.75 kV
5 = 5.5 kV
8 = 8.3 kV
15 = 15.5 kV

Special Mounting
A = Ampgard
B = Bolt-in

3
Class

Continuos Amperes
10-1350

Type
CLE
CLE1
HCL
HLE

3

Size
D = 3-inch dia.

E
X

3
3
3
3

Helix Fuse Mounting

15 CLE - P NM - C
Maximum kV
2 = 2.75 kV
5 = 5.5 kV
8 = 8.3 kV
15 = 15.5 kV

Type
CLE
HCL
HLE

Insulator
G = Glass polyester
P = Porcelain

Hardware
DM = Disconnect mounting
NM = Non-disconnect mounting
DL = Disconnect live parts
NL = Non-disconnect live parts
DF = Disconnect end fittings

3
C
D
E
F

3

Diameter Size
= 2.00 in. (50.8 mm)
single barrel
= 3.00 in. (76.2 mm)
single barrel
= 3.00 in. (76.2 mm)
double barrel
= 4.00 in. (101.6 mm)
double barrel

3
3
3
3

Ratings and Selection
When a decision has been
made to use current limiting
fuses, the minimum amount
of information required to
make the proper selection is:
●
●
●
●

Voltage rating
Current rating
Interrupting rating
Mounting method:
●
Non-disconnect
mounting
●
Disconnect mounting
●
Clip-lock mounting
●
Direct bolt-in mounting
●
Live parts only
●
No required mounting

Refer to tables on Pages
V14-T3-22 to V14-T3-41 for
assistance in selecting the
correct fuse catalog number.

3

These types of fuses
commonly provide protection
for transformer primaries.
There are specific rules
governing the selection of the
required fuse continuous
rating. The current limiting
fuse application notes earlier
in this publication offer
suggested minimum current
limiting fuse current ratings
for self-cooled transformers.
The suggested ratings are
intended as general
guidelines only.

3
3
3
3
3
3
3

When selecting the
appropriate fuse for a new
installation, keep in mind that
one fuse unit and one
compatible mounting is
required for each phase.

3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-21

3.4
3
3
3
3

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

Suggested Minimum Current Limiting Fuse Current Ratings for Self-Cooled 2.4–15.5 kV
Transformer Applications—E-Rated Fuses
System
Nominal
kV
Fuse
Maximum
kV

2.4

4.16

12.0

13.2

13.8

14.4

5.5

5.5

8.3

15.5

15.5

15.5

15.5

Full
Load
Current
Amps

Full
Load
Current
Amps

Fuse
Rating
Amps E

Full
Load
Current
Amps

Fuse
Rating
Amps E

Full
Load
Current
Amps

Fuse
Rating
Amps E

Full
Load
Current
Amps

Fuse
Rating
Amps E

Full
Load
Current
Amps

Fuse
Rating
Amps E

Full
Load
Current
Amps

Fuse
Rating
Amps E

Full
Load
Current
Amps

Fuse
Rating
Amps E

Transformer
kVA Rating
Self-Cooled

3

Three-Phase Transformer

3

7.2

2.75

3
3

4.8

Fuse
Rating
Amps E

9

2.2

5E 

1.3

3E 

1.1

3E 

0.7

3E 

0.4

1E 

0.4

1E 

0.4

1E 

0.4

1E 

15

3.6

10E 

2.1

3E 

1.8

3E 

1.2

3E 

0.7

1.5E 

0.7

1E 

0.6

1E 

0.6

1E 

30

7.2

15E

4.2

10E

3.6

10E

2.4

5E 

1.4

3E 

1.3

3E 

1.3

3E 

1.2

3E 

2.2



2.0

3E



1.9

3E



1.8

3E 



3.1

5E



3.0

5E 
10E

45

10.8

20E

6.2

10E

5.4

10E

3.6

10E

5E

3

75

18.0

30E

10.4

15E

9.0

15E

6.0

10E

3.6

10E

3.3

5E

112.5

27.1

50E

15.6

25E

13.5

20E

9.0

15E

5.4

10E

4.9

10E

4.7

10E

4.5

3

150

36.1

65E

20.8

30E

18.0

30E

12.0

20E

7.2

15E

6.6

10E

6.3

10E

6.0

10E

225

54.1

80E

31.2

50E

27.1

50E

18.0

30E

10.8

20E

9.8

15E

9.4

15E

9.0

15E

300

72.2

125E

41.6

80E

36.1

65E

24.1

40E

14.4

25E

13.1

20E

12.6

20E

12.0

20E

500

120.3

200E

69.4

125E

60.1

100E

40.1

65E

24.1

50E

21.9

40E

20.9

40E

20.0

40E

750

180.4

300E

104.1

150E

90.2

150E

60.1

100E

36.1

65E

32.8

65E

31.4

65E

30.1

65E

3

1000

240.6

350E

138.8

200E

120.3

175E

80.2

125E

48.1

80E

43.7

80E

41.8

80E

40.1

80E

1500

360.8

600E  208.2

300E

180.4

300E

120.3

175E

72.2

125E

65.6

100E

62.8

100E

60.1

100E

3

2000

481.1

750E  277.6

400E

240.6

350E

160.4

250E

96.2

150E

87.5

150E

83.7

150E

80.2

125E

2500

601.4

1100E  347.0

600E 

300.7

450E

200.5

300E

120.3

200E

109.3

175E

104.6

175E

100.2

175E

3
3

3

Single-Phase Transformer

3

5

2.08

3E 

1.20

3E 

1.04

1.5E 

0.69

3E 

0.42

1E 

0.38

1E 

0.36

1E 

0.35

1E 

10

4.17

10E

2.40

5E 

2.08

3E 

1.39

3E 

0.83

1.5E 

0.76

1.5E 

0.72

1.5E 

0.69

1.5E 

3

15

6.25

10E

3.61

10E

3.13

5E 

2.08

3E 

1.25

3E 

1.14

3E 

1.09

3E 

1.04

3E 

2.08



1.89

3E



1.81

3E



1.74

3E 

5E



5E



2.60

5E 

25

3

10.42

15E

6.01

10E

5.21

10E

3.47

5Ev

37.5

15.63

25E

9.01

15E

7.81

15E

5.21

50

20.83

40E

12.02

20E

10.42

15E

6.94

10E

4.17

10E

3.79

10E

3.62

10E

3.47

10E

75

31.25

50E

18.03

30E

15.63

25E

10.42

15E

6.25

10E

5.68

10E

5.43

10E

5.21

10E

3

100

41.67

65E

24.04

50E

20.83

30E

13.89

20E

8.33

15E

7.58

15E

7.25

15E

6.94

15E

167

69.58

100E

40.14

80E

34.79

65E

23.19

40E

13.92

25E

12.65

20E

12.10

20E

11.60

20E

3

250

104.17

150E

60.10

125E

52.08

100E

34.72

65E

20.83

40E

18.94

30E

18.12

30E

17.36

30E

333

138.75

200E

80.05

150E

69.38

125E

46.25

80E

27.75

50E

25.23

50E

24.13

40E

23.13

40E

500

208.33

300E

120.19

175E

104.17

150E

69.44

125E

41.67

80E

37.88

65E

36.23

65E

34.72

65E

667

277.92

400E

160.34

250E

138.96

200E

92.64

150E

55.58

100E

50.53

80E

48.33

80E

46.32

80E

883

367.92

600E  212.26

300E

183.96

300E

122.64

175E

73.58

125E

66.89

125E

63.99

100E

61.32

100E

1250

520.83

750E  300.48

450E

260.42

400E

173.61

250E

104.17

175E

94.70

150E

90.58

150E

86.81

150E

3

3
3
3
3
3

10E

3.13

5E
5E

Notes
 CLPT fuses.
 5CLE fuses.
 Not FM compliant for less flammable transformer liquids.

3
3
3
3
V14-T3-22

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

2.84

2.72

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

3.4

Eaton Helix Fuse I2t Values

3

Ampere Rating Min. Melt

5.5 kV
CLE
63 kA
Max. Clear

Min. Melt

8.3 kV
CLE
50 kA
Max. Clear

Min. Melt

63 kA
Max. Clear

Min. Melt

Max. Clear

10E

720

9000

9000

720

9000

9000

720

9000

720

9000

15E

1600

13,500

13,500

1600

13,500

13,500

1600

13,500

1600

13,500

20E

3000

20,000

20,000

3000

20,000

20,000

3000

20,000

3000

20,000

25E

4500

27,000

27,000

4500

27,000

27,000

4500

27,000

4500

27,000

30E

6500

36,000

36,000

6500

36,000

36,000

6500

36,000

6500

36,000

40E

1000

20,000

20,000

1000

20,000

20,000

1000

20,000

1000

20,000

50E

1500

40,000

40,000

1500

40,000

40,000

1500

40,000

1500

40,000

65E

2600

65,000

65,000

3000

65,000

65,000

2600

65,000

2600

65,000

80E

4300

120,000

120,000

5000

140,000

140,000

5000

140,000

5000

140,000

100E

6400

160,000

160,000

8500

225,000

225,000

8500

225,000

8500

225,000

125E

10,000

200,000

200,000

22,500

275,000

275,000

22,500

270,000

22,500

270,000

150E

36,000

230,000

245,000

30,000

325,000

325,000

42,000

450,000

—

—

175E

53,000

575,000

625,000

48,000

400,000

400,000

—

—

—

—

200E

74,000

600,000

630,000

—

—

—

—

—

—

—

250E

11,500

700,000

900,000

—

—

—

—

—

—

—

150E

—

—

—

—

—

—

—

—

20,000

450,000

175E

—

—

—

—

—

—

22,000

750,000

25,000

750,000

200E

—

—

—

25,000

900,000

900,000

35,000

900,000

34,000

900,000

250E

—

—

—

90,000

1,100,000

1,100,000

100,000

1,000,000

65,000

1,100,000

300E

18,500

1,600,000

1,700,000

145,000

1,300,000

1,300,000

170,000

1,700,000

—

—

350E

225,000

2,000,000

2,100,000

190,000

1,600,000

1,600,000

—

—

—

—

400E

300,000

2,300,000

2,500,000

—

—

—

—

—

—

—

450E

465,000

2,800,000

3,000,000

—

—

—

—

—

—

—

HLE

15.5 kV
HLE

CLE

HLE

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-23

3.4
3
3
3

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

Product Selection
CLE Type
CLE Type Current Limiting Fuses 2.75 kV Maximum (2.4 kV Nominal)

CLE Type

Current Rating
(Amperes)

Barrel
Number

Interrupting Rating
rms (kA Sym.)

Heritage
Product

Indoor/
Outdoor

Performance Curves
Minimum
Total
Melting Time Clearing Time

Peak Let-Through
Current

Catalog
Number

15E

1

50

H

Indoor

TC56353202

TC56353302

TC63931702

2CLE-15E

20E

1

50

H

Indoor

TC56353202

TC56353302

TC63931702

2CLE-20E

3

25E

1

50

H

Indoor

TC56353202

TC56353302

TC63931702

2CLE-25E

10E

1

50

H

Indoor

TC53686104

TC53686204

TC63931704

2CLE-10E

3

30E

1

50

H

Indoor

TC53686104

TC53686204

TC63931704

2CLE-30E

40E

1

50

H

Indoor

TC53686104

TC53686204

TC63931704

2CLE-40E

50E

1

50

H

Indoor

TC53686104

TC53686204

TC63931704

2CLE-50E

65E

1

50

H

Indoor

TC53686104

TC53686204

TC63931704

2CLE-65E

80E

1

50

H

Indoor

TC53686104

TC53686204

TC63931704

2CLE-80E

3

100E

1

50

H

Indoor

TC53686104

TC53686204

TC63931704

2CLE-100E

125E

1

50

H

Indoor

TC53686104

TC53686204

TC63931704

2CLE-125E

3

150E

1

50

H

Indoor

TC53686104

TC53686204

TC63931704

2CLE-150E

200E

1

50

H

Indoor

TC53686104

TC53686204

TC63931704

2CLE-200E

225E

1

50

H

Indoor

TC53686104

TC53686204

TC63931704

2CLE-225E

3

250E

2

50

H

Indoor

TC53690002

TC53690102

TC63931802

2CLE-250E

300E

2

50

H

Indoor

TC53690002

TC53690102

TC63931802

2CLE-300E

3

350X

2

50

H

Indoor

TC53690002

TC53690102

TC63931802

2CLE-350X

400X

2

50

H

Indoor

TC53690002

TC53690102

TC63931802

2CLE-400X

450X

2

50

H

Indoor

TC53690002

TC53690102

TC63931802

2CLE-450X

3
3

3
3

3

3
3
3

CLE Type Mountings and Hardware 2.75 kV Maximum (2.4 kV Nominal)
Mounting
(Including Live Parts, End Fittings) 

3
3

Ampere
Rating

Fuse
Mounting
Type 

Voltage
BIL (kV)

3

15E–25E

Non-disconnect

60

Disconnect

60

3

10E–250E

Non-disconnect

60

Disconnect

60

Non-disconnect

60

Disconnect

60

3

300E–450E

3

Clip
Center

Approx. Dimensions in Inches (mm)

Porcelain Insulator
Catalog Number

Glass-Polyester
Insulator
Catalog Number

Catalog Number

Catalog Number

2.00 (50.8)

2 (0.91)

2CLE-PNM-C

2CLE-GNM-C

CLE-NL-C

—

2CLE-PDM-C

2CLE-GDM-C

CLE-DL-C

CLE-DF-C

2CLE-PNM-D

2CLE-GNM-D

CLE-NL-D

—

2CLE-PDM-D

2CLE-GDM-D

CLE-DL-D

CLE-DF-D

2CLE-PNM-E

2CLE-GNM-E

CLE-NL-E

—

2CLE-PDM-E

2CLE-GDM-E

CLE-DL-E

CLE-DF-E

3.00 (76.2)

7.00 (177.8) 10.90 (276.9) 7 (3.18)

7.00 (177.8) 10.90 (276.9) 15 (6.81)

Fuse Dimensional Details
Approximate Dimensions in Inches (mm)

3

CLE Type Fuse

“B” Dia.
“L”

3.31
Ref.
(84.1)

3

CLE kV

“L”

“B” Dia.

15E–25E

9.50 (241.3)

2.00 (50.8)

10E–450E

10.90 (276.9)

3.00 (76.2)

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3
3

Length

8.13 (206.5) 9.50 (241.3)

3

3

“L”

V14-T3-24

End Fittings
(Disconnect Only)

Approximate
Shipping
Weight Lbs (kg)

Diameter

3.00 (76.2)

3

Live Parts
(Including
End Fittings) 

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.4

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

CLE Type Current Limiting Fuses 5.5 kV Maximum (4.8 kV Nominal)

CLE Type

Current Rating
(Amperes)

Barrel
Number

Interrupting Rating
rms (kA Sym.)

Heritage
Product

Indoor/
Outdoor

Performance Curves
Minimum
Total
Melting Time
Clearing Time

15E
20E
25E
10E
15E
20E
25E
30E
40E
50E
65E
80E
100E
125E
150E
175E
200E
250E
300E
350E
400E
450E
600E
750E
1100E
1350E

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
4
4

50
50
50
63
63
63
63
63
50
50
50
50
50
50
63
63
63
63
63
63
63
63
40
40
31
31

H
H
H
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

Indoor
Indoor
Indoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor
Indoor
Indoor
Indoor

TC56353204
TC56353204
TC56353204
TC70548501
TC70548501
TC70548501
TC70548501
TC70548501
TC70545801
TC70545801
TC70545801
TC70545801
TC70545801
TC70545801
TC70545801
TC70545801
TC70545801
TC70545801
TC70546001
TC70546001
TC70546001
TC70546001
TC62908902
TC62908902
TC62908902
TC62908902

TC56353304
TC56353304
TC56353304
TC70548601
TC70548601
TC70548601
TC70548601
TC70548601
TC70545901
TC70545901
TC70545901
TC70545901
TC70545901
TC70545901
TC70545901
TC70545901
TC70545901
TC70545901
TC70546101
TC70546101
TC70546101
TC70546101
TC62908903
TC62908903
TC62908903
TC62908903

3
Peak Let-Through
Current

Catalog
Number

3

TC63931702
TC63931702
TC63931702
TC70548701
TC70548701
TC70548701
TC70548701
TC70548701
TC70546701
TC70546701
TC70546701
TC70546701
TC70546701
TC70546701
TC70547601
TC70547601
TC70547601
TC70547601
TC70547601
TC70547601
TC70547601
TC70547601
TC62908904
TC62908904
TC62908904
TC62908904

5CLE-15E
5CLE-20E
5CLE-25E
5CLE-10E-D
5CLE-15E-D
5CLE-20E-D
5CLE-25E-D
5CLE-30E
5CLE-40E
5CLE-50E
5CLE-65E
5CLE-80E
5CLE-100E
5CLE-125E
5CLE-150E
5CLE-175E
5CLE-200E
5CLE-250E
5CLE-300E
5CLE-350E
5CLE-400E
5CLE-450E
5CLE-600E
5CLE-750E
5CLE-1100E
5CLE-1350E

3

Mounting
(Including Live Parts, End Fittings) 

10E-D–25E-D
30E–250E
15E–25E
300E–450E
600E and 750E
1100E and 1350E

Fuse
Mounting
Type 

Clip
Center
Length
Voltage Diameter
BIL (kV) Approx. Dimensions in Inches (mm)

Non-disconnect
Disconnect
Non-disconnect
Disconnect
Non-disconnect
Disconnect
Consult factory
Consult factory

60
60
60
60
60
60
60
—

Approximate
Porcelain Insulator
Shipping
Weight Lbs (kg) Catalog Number

3.00 (76.2)

14.00 (355.6) 17.90 (454.7) 9 (4.09)

2.00 (50.8)

11.50 (292.1) 12.90 (327.7) 3 (1.36)

3.00 (76.2)

14.00 (355.6) 17.90 (454.7) 19 (8.63)

4.00 (101.6)
4.00 (101.6)

N/A
N/A

N/A
N/A

5CLE-PNM-D
5CLE-PDM-D
5CLE-PNM-C
5CLE-PDM-C
5CLE-PNM-E
5CLE-PDM-E
—
—

40 (18.16)
80 (36.32)

3
3
3
3
3
3
3
3
3
3
3
3

CLE Type Mountings and Hardware 5.5 kV Maximum (4.8 kV Nominal)

Ampere
Rating

3

Live Parts
(Including
End Fittings) 

End Fittings
(Disconnect Only)

Glass-Polyester
Insulator
Catalog Number

Catalog Number Catalog Number

5CLE-GNM-D
5CLE-GDM-D
5CLE-GNM-C
5CLE-GDM-C
5CLE-GNM-E
5CLE-GDM-E
—
—

CLE-NL-D
CLE-DL-D
CLE-NL-C
CLE-DL-C
CLE-NL-E
CLE-DL-E
—
—

3
3

—
CLE-DF-D
—
CLE-DF-C
—
CLE-DF-E
—
—

3
3
3
3
3

Fuse Dimensional Details
Approximate Dimensions in Inches (mm)

3

CLE Type Fuse

3
“B” Dia.
“L”

CLE kV

“L”

“B” Dia.

15E–25E

12.90 (327.7)

2.00 (50.8)

10E–450E

17.90 (454.7)

3.00 (76.2)

3
3

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3.31
Ref.
(84.1)

3
3

“L”

3
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-25

3.4
3

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

CLE Type Current Limiting Fuses 8.3 kV Maximum (7.2 kV Nominal)

CLE Type

3

Current Rating
(Amperes)

Barrel
Number

Interrupting Rating
rms (kA Sym.)

Heritage
Product

Indoor/
Outdoor

Performance Curves
Minimum
Total
Melting Time
Clearing Time

Peak Let-Through
Current

Catalog
Number

3

15E

1

50

H

Indoor

TC56353204

TC56353304

TC63931703

8CLE-15E

20E

1

50

H

Indoor

TC56353204

TC56353304

TC63931703

8CLE-20E

3

25E

1

50

H

Indoor

TC56353204

TC56353304

TC63931703

8CLE-25E

10E

1

50

—

Indoor/outdoor

TC70548501

TC70548601

TC70548801

8CLE-10E-D

15E

1

50

—

Indoor/outdoor

TC70548501

TC70548601

TC70548801

8CLE-15E-D

20E

1

50

—

Indoor/outdoor

TC70548501

TC70548601

TC70548801

8CLE-20E-D

25E

1

50

—

Indoor/outdoor

TC70548501

TC70548601

TC70548801

8CLE-25E-D

3

30E

1

50

—

Indoor/outdoor

TC70548501

TC70548601

TC70548801

8CLE-30E

40E

1

50

—

Indoor/outdoor

TC70546201

TC70546301

TC70547301

8CLE-40E

3

50E

1

50

—

Indoor/outdoor

TC70546201

TC70546301

TC70547301

8CLE-50E

65E

1

50

—

Indoor/outdoor

TC70546201

TC70546301

TC70547301

8CLE-65E

3
3

3

80E

1

50

—

Indoor/outdoor

TC70546201

TC70546301

TC70547301

8CLE-80E

3

100E

1

50

—

Indoor/outdoor

TC70546201

TC70546301

TC70547301

8CLE-100E

125E

1

50

—

Indoor/outdoor

TC70546201

TC70546301

TC70547301

8CLE-125E

3

150E

1

50

—

Indoor/outdoor

TC70546201

TC70546301

TC70547301

8CLE-150E

175E

1

50

—

Indoor/outdoor

TC70546201

TC70546301

TC70547301

8CLE-175E

200E

2

50

—

Indoor/outdoor

TC70546401

TC70546501

TC70547301

8CLE-200E

250E

2

50

—

Indoor/outdoor

TC70546401

TC70546501

TC70547301

8CLE-250E

300E

2

50

—

Indoor/outdoor

TC70546401

TC70546501

TC70547301

8CLE-300E

350E

2

50

—

Indoor/outdoor

TC70546401

TC70546501

TC70547301

8CLE-350E

3
3
3
3

CLE Type Mountings and Hardware 8.3 kV Maximum (7.2 kV Nominal)

3
3
3
3
3
3
3
3

Mounting
(Including Live Parts, End Fittings) 
Ampere
Rating

Fuse
Mounting
Type 

Voltage
BIL (kV)

15E–25E

Non-disconnect

75

Disconnect

75

10E-D–25E-D Non-disconnect
30E–175E
Disconnect

75

200E–350E

Non-disconnect

75

Disconnect

75

Clip
Center

Approx. Dimensions in Inches (mm)

Glass-Polyester
Insulator
Catalog Number

Catalog Number Catalog Number

2.00 (50.8)

3 (1.36)

8CLE-PNM-C

8CLE-GNM-C

CLE-NL-C

8CLE-PDM-C

8CLE-GDM-C

CLE-DL-C

CLE-DF-C

8CLE-PNM-D

8CLE-GNM-D

CLE-NL-D

—

8CLE-PDM-D

8CLE-GDM-D

CLE-DL-D

CLE-DF-D

8CLE-PNM-E

8CLE-GNM-E

CLE-NL-E

—

8CLE-PDM-E

8CLE-GDM-E

CLE-DL-E

CLE-DF-E

14.00 (355.6)

Length
15.50 (393.7)

3.00 (76.2)

14.00 (355.6)

17.90 (454.7)

9 (4.09)

3.00 (76.2)

14.00 (355.6)

17.90 (454.7)

19 (8.63)

75

Fuse Dimensional Details
Approximate Dimensions in Inches (mm)
CLE Type Fuse

3

“B” Dia.

CLE kV

“L”

“B” Dia.

15E–25E

15.50 (393.7)

2.00 (50.8)

10E–350E

17.90 (454.7)

3.00 (76.2)

“L”

3

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3.31
Ref.
(84.1)

3
“L”

3
3
V14-T3-26

End Fittings
(Disconnect Only)

Approximate
Porcelain Insulator
Shipping
Weight Lbs (kg) Catalog Number

Diameter

3

3

Live Parts
(Including
End Fittings) 

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

—

3.4

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

CLE Type Current Limiting Fuses 15.5 kV Maximum (14.4 kV Nominal)

CLE Type

3

Current Rating
(Amperes)

Barrel
Number

Interrupting Rating
rms (kA Sym.)

Heritage
Product

Indoor/
Outdoor

Performance Curves
Minimum
Total
Melting Time Clearing Time

15E
20E
25E
10E
15E
20E

1
1
1
1
1
1

31.5
31.5
31.5
63
63
63

H
H
H
—
—
—

Indoor
Indoor
Indoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor

TC56353204
TC56353204
TC56353204
TC70548501
TC70548501
TC70548501

TC56353304
TC56353304
TC56353304
TC70548601
TC70548601
TC70548601

TC63931703
TC63931703
TC63931703
TC70548802
TC70548802
TC70548802

15CLE-15E
15CLE-20E
15CLE-25E
15CLE-10E-D
15CLE-15E-D
15CLE-20E-D

25E
30E
40E
50E
65E
80E
100E
125E
150E
175E
200E
250E
300E
80E
100E
125X
150E
175E/200X

1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
3
3

63
63
63
63
63
63
63
63
63
63
63
63
63
85
85
85
50
50

—
—
—
—
—

Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor/outdoor
Indoor
Indoor
Indoor
Indoor
Indoor

TC70548501
TC70548501
TC70546801
TC70546801
TC70546801
TC70546801
TC70546801
TC70546801
TC70546801
TC70547001
TC70547001
TC70547001
TC70547001
TC59878302
TC59878302
TC59878302
TC59878302
TC59878302

TC70548601
TC70548601
TC70546901
TC70546901
TC70546901
TC70546901
TC70546901
TC70546901
TC70546901
TC70547101
TC70547101
TC70547101
TC70547101
TC59878402
TC59878402
TC59878402
TC59878402
TC59878402

TC70548802
TC70548802
TC70547501
TC70547501
TC70547501
TC70547501
TC70547501
TC70547501
TC70547501
TC70547501
TC70547501
TC70547501
TC70547501
TC63931604
TC63931604
TC63931604
TC63931604
TC63931604

15CLE-25E-D
15CLE-30E
15CLE-40E
15CLE-50E
15CLE-65E
15CLE-80E
15CLE-100E
15CLE-125E
15CLE-150E
15CLE-175E
15CLE-200E
15CLE-250E
15CLE-300E
15CLE2-80E
15CLE2-100E
15CLE2-125X
15CLE3-150E
15CLE3-175E/200X










H
H
H
H
H

Peak Let-Through
Current

Catalog
Number

3
3

Mounting
(Including Live Parts, End Fittings) 
Fuse
Mounting
Type 

15E–25E

Non-disconnect
Disconnect

10E-D–25E-D
30E–150E

Non-disconnect
Disconnect

175E–300E

Non-disconnect
Disconnect

Voltage
BIL (kV)
95
110
95
110
95
110
95
110
110
110

Diameter

Clip
Center

Length

Approx. Dimensions in Inches (mm)
2.00 (50.8)

3.00 (76.2)

3.00 (76.2)

Approximate
Porcelain Insulator
Shipping
Weight Lbs (kg) Catalog Number

20.00 (508.0) 21.50 (546.1) 4.5 (2.04)

15CLE-PNM-C
15CLE-HPNM-C
15CLE-PDM-C
15CLE-HPDM-C
15CLE-PNM-D
15CLE-HPM-D
15CLE-PDM-D
15CLE-HPDM-D
15CLE-PNM-E
15CLE-PDM-E

20.00 (508.0) 23.90 (607.1) 11 (4.99)

20.00 (508.0) 23.90 (607.1) 23 (10.44)

3
3
3
3
3
3
3
3
3
3
3

CLE Type Mountings and Hardware 15.5 kV Maximum (14.4 kV Nominal)

Ampere
Rating

3

Live Parts
(Including
End Fittings) 

End Fittings
(Disconnect Only)

3
3

Glass-Polyester
Insulator
Catalog Number

Catalog Number Catalog Number

15CLE-GNM-C
—
15CLE-GDM-C
—
15CLE-GNM-D
—
15CLE-GNM-D
—
—
—

CLE-NL-D
—
CLE-DL-C
—
CLE-NL-D
—
CLE-DL-D
—
CLE-DL-E
—

—
—
CLE-DF-C
—
—
—
CLE-DF-D
—
CLE-DF-E
—

Fuse Dimensional Details
Approximate Dimensions in Inches (mm)

3
3
3
3
3
3
3

CLE Type Fuse

3
“B” Dia.
“L”

CLE kV

“L”

“B” Dia.

15E–25E

21.50 (546.1)

2.00 (50.8)

10E–300E

23.90 (607.1)

3.00 (76.2)

3
3

Notes
 For mountings, consult factory.
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3.31
Ref.
(84.1)

3
3
3

“L”

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-27

3.4
3
3

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

HLE Type
HLE Type Current Limiting Fuses 5.5 kV Maximum (4.8 kV Nominal) Interrupting Rating 63 (kA rms Sym.)

HLE Type

3

Current Rating
(Amperes)

Barrel
Number

Indoor/
Outdoor

Performance Curves
Minimum
Total
Melting Time
Clearing Time

Peak Let-Through
Current

Catalog
Number

3

10E

1

Indoor/outdoor

TC70548507

TC70548607

TC70548703

5HLE-10E

15E

1

Indoor/outdoor

TC70548507

TC70548607

TC70548703

5HLE-15E

20E

1

Indoor/outdoor

TC70548507

TC70548607

TC70548703

5HLE-20E

3

25E

1

Indoor/outdoor

TC70548507

TC70548607

TC70548703

5HLE-25E

30E

1

Indoor/outdoor

TC70548507

TC70548607

TC70548703

5HLE-30E

3

40E

1

Indoor/outdoor

TC70545805

TC70545905

TC70547603

5HLE-40E

50E

1

Indoor/outdoor

TC70545805

TC70545905

TC70547603

5HLE-50E

65E

1

Indoor/outdoor

TC70545805

TC70545905

TC70547603

5HLE-65E

80E

1

Indoor/outdoor

TC70545805

TC70545905

TC70547603

5HLE-80E

100E

1

Indoor/outdoor

TC70545805

TC70545905

TC70547603

5HLE-100E

3

125E

1

Indoor/outdoor

TC70545805

TC70545905

TC70547603

5HLE-125E

150E

1

Indoor/outdoor

TC70545805

TC70545905

TC70547603

5HLE-150E

3

175E

1

Indoor/outdoor

TC70545805

TC70545905

TC70547603

5HLE-175E

200E

1

Indoor/outdoor

TC70545805

TC70545905

TC70547603

5HLE-200E

250E

1

Indoor/outdoor

TC70545805

TC70545905

TC70547603

5HLE-250E

300E

2

Indoor/outdoor

TC70546005

TC70546105

TC70547603

5HLE-300E

350E

2

Indoor/outdoor

TC70546005

TC70546105

TC70547603

5HLE-350E

400E

2

Indoor/outdoor

TC70546005

TC70546105

TC70547603

5HLE-400E

450E

2

Indoor/outdoor

TC70546005

TC70546105

TC70547603

5HLE-450E

3

3
3

3
3
3
3
3

HLE Type Mountings and Hardware 5.5 kV Maximum (4.8 kV Nominal)
Mounting
(Including Live Parts, End Fittings) 

3
Clip
Center

3

Fuse
Mounting
Type 

Voltage
BIL (kV)

Approx. Dimensions in Inches (mm)

3

10E–250E

Non-disconnect

60

3.00 (76.2)

12.00 (304.8) 15.90 (403.9) 8 (3.63)

3

300E–450E

3.00 (76.2)

12.00 (304.8) 15.90 (403.9) 17 (7.72)

3
3
3

Disconnect

60

Non-disconnect

60

Disconnect

60

Length

Catalog Number Catalog Number

5HLE-PNM-D

5HLE-GNM-D

CLE-NL-D

—

5HLE-PDM-D

5HLE-GDM-D

CLE-DL-D

CLE-DF-D

5HLE-PNM-E

5HLE-GNM-E

CLE-NL-E

—

5HLE-PDM-E

5HLE-GDM-E

CLE-DL-E

CLE-DF-D

Fuse Dimensional Details
Approximate Dimensions in Inches (mm)
HLE Type Fuse

3

3.00
Dia.
(76.2)

3

L ± 0.03

3
3

Diameter

HLE kV

L ± 0.03

5.5

15.88 (403.4)

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3.31
(84.1)

3

L ± 0.03

3
3
V14-T3-28

End Fittings
(Disconnect Only)

Glass-Polyester
Insulator
Catalog Number

Approximate
Porcelain Insulator
Shipping
Weight Lbs (kg) Catalog Number

Ampere
Rating

Live Parts
(Including
End Fittings) 

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.4

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

HLE Type Current Limiting Fuses 8.3 kV Maximum (7.2 kV Nominal) Interrupting Rating 50 (kA Sym.)

HLE Type

Current Rating
(Amperes)

Barrel
Number

Indoor/
Outdoor

Performance Curves
Minimum
Total
Melting Time
Clearing Time

10E

1

Indoor/outdoor

TC70548507

TC70548607

TC70548804

8HLE-10E

15E

1

Indoor/outdoor

TC70548507

TC70548607

TC70548804

8HLE-15E

20E

1

Indoor/outdoor

TC70548507

TC70548607

TC70548804

8HLE-20E

25E

1

Indoor/outdoor

TC70548507

TC70548607

TC70548804

8HLE-25E

30E

1

Indoor/outdoor

TC70548507

TC70548607

TC70548804

8HLE-30E

40E

1

Indoor/outdoor

TC70546203

TC70546303

TC70547201

8HLE-40E

50E

1

Indoor/outdoor

TC70546203

TC70546303

TC70547201

8HLE-50E

65E

1

Indoor/outdoor

TC70546203

TC70546303

TC70547201

8HLE-65E

80E

1

Indoor/outdoor

TC70546203

TC70546303

TC70547201

8HLE-80E

100E

1

Indoor/outdoor

TC70546203

TC70546303

TC70547201

8HLE-100E

125E

1

Indoor/outdoor

TC70546203

TC70546303

TC70547201

8HLE-125E

150E

1

Indoor/outdoor

TC70546203

TC70546303

TC70547201

8HLE-150E

175E

1

Indoor/outdoor

TC70546203

TC70546303

TC70547201

8HLE-175E

200E

2

Indoor/outdoor

TC70546403

TC70546503

TC70547201

8HLE-200E

250E

2

Indoor/outdoor

TC70546403

TC70546503

TC70547201

8HLE-250E

300E

2

Indoor/outdoor

TC70546403

TC70546503

TC70547201

8HLE-300E

350E

2

Indoor/outdoor

TC70546403

TC70546503

TC70547201

8HLE-350E

Peak Let-Through
Current

Catalog
Number

3
3

Mounting
(Including Live Parts, End Fittings) 
Clip
Center

End Fittings
(Disconnect Only)

Catalog Number Catalog Number

8HLE-PNM-D

8HLE-GNM-D

CLE-NL-D

—

75

8HLE-PDM-D

8HLE-GDM-D

CLE-DL-D

CLE-DF-D

Non-disconnect

75

8HLE-PNM-E

8HLE-GNM-E

CLE-NL-E

—

Disconnect

75

8HLE-PDM-E

8HLE-GDM-E

CLE-DL-E

CLE-DF-E

Voltage
BIL (kV)

Approx. Dimensions in Inches (mm)

10E–175E

Non-disconnect

75

3.00 (76.2)

Disconnect
200E–350E

Live Parts
(Including
End Fittings) 

Glass-Polyester
Insulator
Catalog Number

Fuse
Mounting
Type 

Diameter

Length

Approximate
Porcelain Insulator
Shipping
Weight Lbs (kg) Catalog Number

12.00 (304.8) 15.90 (403.9) 8 (3.63)

3
3
3
3
3
3
3
3
3
3
3
3
3
3

Fuse Dimensional Details
Approximate Dimensions in Inches (mm)

3

HLE Type Fuse

3.00
Dia.
(76.2)
L ± 0.03

3

3

HLE Type Mountings and Hardware 8.3 kV Maximum (7.2 kV Nominal)

Ampere
Rating

3

HLE kV

L ± 0.03

8.3

15.88 (403.4)

3
3

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3
3

3.31
(84.1)

3
L ± 0.03

3
3
3
3
3
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-29

3.4
3

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

HLE Type Current Limiting Fuses 15.5 kV Maximum (14.4 kV Nominal)

HLE Type

3

Current Rating
(Amperes)

Barrel
Number

Interrupting Rating
rms (kA Sym.)

Indoor/
Outdoor

Performance Curves
Minimum
Total
Melting Time
Clearing Time

Peak Let-Through
Current

Catalog
Number

3

10E

1

63

Indoor/outdoor

TC70548507

TC70548607

TC70548805

15HLE-10E

15E

1

63

Indoor/outdoor

TC70548507

TC70548607

TC70548805

15HLE-15E

3

20E

1

63

Indoor/outdoor

TC70548507

TC70548607

TC70548805

15HLE-20E

25E

1

63

Indoor/outdoor

TC70548507

TC70548607

TC70548805

15HLE-25E

30E

1

63

Indoor/outdoor

TC70548507

TC70548607

TC70548805

15HLE-30E

40E

1

63

Indoor/outdoor

TC70546601

TC70546701

TC70547401

15HLE-40E

50E

1

63

Indoor/outdoor

TC70546601

TC70546701

TC70547401

15HLE-50E

3

65E

1

63

Indoor/outdoor

TC70546601

TC70546701

TC70547401

15HLE-65E

80E

1

63

Indoor/outdoor

TC70546601

TC70546701

TC70547401

15HLE-80E

3

100E

1

63

Indoor/outdoor

TC70546601

TC70546701

TC70547401

15HLE-100E

125E

1

63

Indoor/outdoor

TC70546601

TC70546701

TC70547401

15HLE-125E

150E

2

63

Indoor/outdoor

TC70546601

TC70546701

TC70547401

15HLE-150E

3

175E

2

63

Indoor/outdoor

TC70546601

TC70546701

TC70547401

15HLE-175E

200E

2

63

Indoor/outdoor

TC70546601

TC70546701

TC70547401

15HLE-200E

3

250E

2

63

Indoor/outdoor

TC70546601

TC70546701

TC70547401

15HLE-250E

3
3

3

3

HLE Type Mountings and Hardware 15.5 kV Maximum (14.4 kV Nominal)

3
3
3

Mounting
(Including Live Parts, End Fittings) 
Fuse
Mounting
Type 

Voltage
BIL (kV)

Approx. Dimensions in Inches (mm)

10E–175E

Non-disconnect

95

3.00 (76.2)

Disconnect

95

Non-disconnect

95

Disconnect

95

3
150E–250E

3
3
3

Clip
Center

Ampere
Rating

Diameter

3.00 (76.2)

15.00 (381.0) 18.90 (480.1) 21 (9.53)

15HLE-GNM-D

CLE-NL-D

—

15HLE-PDM-D

15HLE-GDM-D

CLE-DL-D

CLE-DF-D

15HLE-PNM-E

—

CLE-NL-E

—

15HLE-PDM-E

—

CLE-DL-E

CLE-DF-E

HLE Type Fuse

3
L ± 0.03

3
3

Catalog Number Catalog Number

15HLE-PNM-D

Fuse Dimensional Details
Approximate Dimensions in Inches (mm)

3.00
Dia.
(76.2)

HLE kV

L ± 0.03

15.5

18.88 (479.6)

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3.31
(84.1)

L ± 0.03

3
3
3
3
3
3
V14-T3-30

End Fittings
(Disconnect Only)

Glass-Polyester
Insulator
Catalog Number

Approximate
Porcelain Insulator
Shipping
Weight Lbs (kg) Catalog Number

15.00 (381.0) 18.90 (480.1) 10 (4.54)

3

3

Length

Live Parts
(Including
End Fittings) 

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

3.4

LHLE Type

3
LHLE Type Current Limiting Fuses 15.5 kV Maximum (14.4 kV Nominal) Indoor/Outdoor.

LHLE Type

Approximate Dimensions
in Inches (mm)

3

Performance Curves
Minimum
Total
Melting Time
Clearing Time

Peak Let-Through
Current

Catalog
Number

Current
Rating
(Amperes)

Barrel
Number

Diameter

Length

Approximate
Shipping
Weight Lbs (kg)

65E

1

3.00 (76.2)

20.53 (521.5)

10.5 (4.80)

TC66703203

TC66703303

TC70547404

15LHLE-65E

80E

1

3.00 (76.2)

20.53 (521.5)

10.5 (4.80)

TC66703203

TC66703303

TC70547404

15LHLE-80E

100E

1

3.00 (76.2)

20.53 (521.5)

10.5 (4.80)

TC66703203

TC66703303

TC70547404

15LHLE-100E

125E

1

3.00 (76.2)

20.53 (521.5)

10.5 (4.80)

TC66703203

TC66703303

TC70547404

15LHLE-125E

150E

1

3.00 (76.2)

20.53 (521.5)

10.5 (4.80)

TC66703203

TC66703303

TC70547404

15LHLE-150E

125E

2

3.00 (76.2)

20.53 (521.5)

21.0 (9.50)

TC66703203

TC66703303

TC70547404

15LHLE2-125E

150E

2

3.00 (76.2)

20.53 (521.5)

21.0 (9.50)

TC66703203

TC66703303

TC70547404

15LHLE2-150E

175E

2

3.00 (76.2)

20.53 (521.5)

21.0 (9.50)

TC66703203

TC66703303

TC70547404

15LHLE-175E

200E

2

3.00 (76.2)

20.53 (521.5)

21.0 (9.50)

TC66703203

TC66703303

TC70547404

15LHLE-200E

250E

2

3.00 (76.2)

20.53 (521.5)

21.0 (9.50)

TC66703203

TC66703303

TC70547404

15LHLE-250E

300E

2

3.00 (76.2)

20.53 (521.5)

21.0 (9.50)

TC66703203

TC66703303

TC70547404

15LHLE-300E

Clip
Diameter
Center
Length
Approximate Dimensions in Inches (mm)

Live Parts
(Including
End Fittings)
Catalog Number

End Fittings
(Disconnect Only)
Catalog Number

65E–150E Single Non-disconnect
barrel
Disconnect

3.00 (76.2)

18.00 (457.0)

20.53 (521.5)

CLE-NL-D

—

CLE-DL-D

CLE-DF-D

125E–300E
Double barrel

3.00 (76.2)

18.00 (457.0)

20.53 (521.5)

CLE-NL-E

—

CLE-DL-E

CLE-DF-E

Fuse
Mounting
Type

Non-disconnect
Disconnect

3
3
3
3
3
3
3
3

LHLE Type Mountings and Hardware 15.5 kV Maximum (14.4 kV Nominal)

Ampere
Rating

3

3
3
3
3
3

Fuse Dimensional Details
Approximate Dimensions in Inches (mm)

3

LHLE Type Fuse

3
3.00
Dia.
(76.2)

LHLE kV

L ± 0.03

15.5

20.53 (521.5)

3
3

L ± 0.03

3
3.31
(84.1)

3
3

L ± 0.03

3
3
3
3
3
3
3
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-31

3.4
3
3

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

AHLE Type
5AHLE Type Current-Limiting Fuse Units 5.5 kV Maximum (4.8 kV Nominal)

3

Current Rating
(Amperes)

Barrel
Number

Interrupting Rating
rms (kA Sym.)

Approximate
Shipping
Weight Lbs (kg)

Performance Curves
Minimum
Total
Melting Time
Clearing Time

Peak Let-Through
Current

Catalog
Number

3

10E

1

63

8 (3.6)

TC70548507

TC70548607

TC70548703

5AHLE-10E

15E

1

63

8 (3.6)

TC70548507

TC70548607

TC70548703

5AHLE-15E

3

20E

1

63

8 (3.6)

TC70548507

TC70548607

TC70548703

5AHLE-20E

25E

1

63

8 (3.6)

TC70548507

TC70548607

TC70548703

5AHLE-25E

30E

1

63

8 (3.6)

TC70548507

TC70548607

TC70548703

5AHLE-30E

40E

1

63

8 (3.6)

TC70545805

TC70545905

TC70547603

5AHLE-40E

50E

1

63

8 (3.6)

TC70545805

TC70545905

TC70547603

5AHLE-50E

3

65E

1

63

8 (3.6)

TC70545805

TC70545905

TC70547603

5AHLE-65E

80E

1

63

8 (3.6)

TC70545805

TC70545905

TC70547603

5AHLE-80E

3

100E

1

63

8 (3.6)

TC70545805

TC70545905

TC70547603

5AHLE-100E

125E

1

63

8 (3.6)

TC70545805

TC70545905

TC70547603

5AHLE-125E

150E

1

63

8 (3.6)

TC70545805

TC70545905

TC70547603

5AHLE-150E

175E

1

63

8 (3.6)

TC70545805

TC70545905

TC70547603

5AHLE-175E

200E

1

63

8 (3.6)

TC70545805

TC70545905

TC70547603

5AHLE-200E

3

250E

1

63

8 (3.6)

TC70545805

TC70545905

TC70547603

5AHLE-250E

300E

2

63

17 (7.8)

TC70546005

TC70546105

TC70547603

5AHLE-300E

3

350E

2

63

17 (7.8)

TC70546005

TC70546105

TC70547603

5AHLE-350E

400E

2

63

17 (7.8)

TC70546005

TC70546105

TC70547603

5AHLE-400E

450E

2

63

17 (7.8)

TC70546005

TC70546105

TC70547603

5AHLE-450E

3
3

3
3

3
3
3

8AHLE Type Current-Limiting Fuse Units 8.3 kV Maximum (7.2 kV Nominal)

3

Current Rating
(Amperes)

Barrel
Number

Interrupting Rating
rms (kA Sym.)

Approximate
Shipping
Weight Lbs (kg)

Performance Curves
Minimum
Total
Melting Time
Clearing Time

Peak Let-Through
Current

Catalog
Number

3

10E

1

50

8 (3.6)

TC70548507

TC70548607

TC70548804

8AHLE-10E

15E

1

50

8 (3.6)

TC70548507

TC70548607

TC70548804

8AHLE-15E

3

20E

1

50

8 (3.6)

TC70548507

TC70548607

TC70548804

8AHLE-20E

25E

1

50

8 (3.6)

TC70548507

TC70548607

TC70548804

8AHLE-25E

3

30E

1

50

8 (3.6)

TC70548507

TC70548607

TC70548804

8AHLE-30E

40E

1

50

8 (3.6)

TC70546203

TC70546303

TC70547201

8AHLE-40E

50E

1

50

8 (3.6)

TC70546203

TC70546303

TC70547201

8AHLE-50E

3

65E

1

50

8 (3.6)

TC70546203

TC70546303

TC70547201

8AHLE-65E

80E

1

50

8 (3.6)

TC70546203

TC70546303

TC70547201

8AHLE-80E

3

100E

1

50

8 (3.6)

TC70546203

TC70546303

TC70547201

8AHLE-100E

125E

1

50

8 (3.6)

TC70546203

TC70546303

TC70547201

8AHLE-125E

150E

1

50

8 (3.6)

TC70546203

TC70546303

TC70547201

8AHLE-150E

175E

1

50

8 (3.6)

TC70546203

TC70546303

TC70547201

8AHLE-175E

200E

2

50

17 (7.8)

TC70546403

TC70546503

TC70547201

8AHLE-200E

3

3
3
3
3
3

250E

2

50

17 (7.8)

TC70546403

TC70546503

TC70547201

8AHLE-250E

300E

2

50

17 (7.8)

TC70546403

TC70546503

TC70547201

8AHLE-300E

350E

2

50

17 (7.8)

TC70546403

TC70546503

TC70547201

8AHLE-350E

Note: These fuses are equipped for mounting in Eaton Ampgard motor starting assemblies.

3
3
V14-T3-32

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.4

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

BHLE Type

3

BHLE Type Current Limiting Fuses 5.5 kV Maximum (4.8 kV Nominal), Indoor, Bolt-In

3

Diameter
Length
Approximate Dimensions
in Inches (mm)

Performance Curves
Approximate
Shipping
Minimum
Total
Weight Lbs (kg) Melting Time
Clearing Time

Peak Let-Through
Current

Catalog
Number

3
3

Current Rating
(Amperes)

Barrel
Number

Interrupting
Rating rms
(kA Sym.)

10E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70548507

TC70548607

TC70548703

5BHLE-10E

15E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70548507

TC70548607

TC70548703

5BHLE-15E

20E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70548507

TC70548607

TC70548703

5BHLE-20E

25E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70548507

TC70548607

TC70548703

5BHLE-25E

30E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70548507

TC70548607

TC70548703

5BHLE-30E

40E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70545805

TC70545905

TC70547603

5BHLE-40E

50E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70545805

TC70545905

TC70547603

5BHLE-50E

65E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70545805

TC70545905

TC70547603

5BHLE-65E

80E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70545805

TC70545905

TC70547603

5BHLE-80E

100E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70545805

TC70545905

TC70547603

5BHLE-100E

125E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70545805

TC70545905

TC70547603

5BHLE-125E

150E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70545805

TC70545905

TC70547603

5BHLE-150E

175E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70545805

TC70545905

TC70547603

5BHLE-175E

200E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70545805

TC70545905

TC70547603

5BHLE-200E

250E

1

63

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70545805

TC70545905

TC70547603

5BHLE-250E

300E

2

63

3.00 (76.2)

15.90 (403.9)

17 (7.72)

TC70546005

TC70546105

TC70547603

5BHLE-300E

350E

2

63

3.00 (76.2)

15.90 (403.9)

17 (7.72)

TC70546005

TC70546105

TC70547603

5BHLE-350E

400E

2

63

3.00 (76.2)

15.90 (403.9)

17 (7.72)

TC70546005

TC70546105

TC70547603

5BHLE-400E

450E

2

63

3.00 (76.2)

15.90 (403.9)

17 (7.72)

TC70546005

TC70546105

TC70547603

5BHLE-450E

3
3
3
3
3
3
3
3
3
3
3

Fuse Dimensional Details
Approximate Dimensions in Inches (mm)
5BHLE Type Fuse—Single Barrel

3
5BHLE Type Fuse—Double Barrel

3

Indicator to be
Located Here

3.31
(84.1)

2.12
(53.8)

3
3
3

3.00
(76.2)
Ref.

17.88 0.06
(454.2)

17.88 0.06
(454.2)

19.25
Ref.
(488.9)

19.25
Ref.
(488.9)

3.00
(76.2)
Ref.

2.12
(53.8)

3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-33

3.4
3

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

BHLE Type Current Limiting Fuses 8.3 kV Maximum (7.2 kV Nominal), Indoor, Bolt-In
Diameter
Length
Approximate Dimensions
in Inches (mm)

Performance Curves
Approximate
Shipping
Minimum
Total
Weight Lbs (kg) Melting Time
Clearing Time

Peak Let-Through
Current

Catalog
Number

3
3

10E

1

50

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70548507

TC70548607

TC70548804

8BHLE-10E

15E

1

50

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70548507

TC70548607

TC70548804

8BHLE-15E

3

20E

1

50

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70548507

TC70548607

TC70548804

8BHLE-20E

25E

1

50

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70548507

TC70548607

TC70548804

8BHLE-25E

30E

1

50

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70548507

TC70548607

TC70548804

8BHLE-30E

3

40E

1

50

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70546203

TC70546303

TC70547201

8BHLE-40E

50E

1

50

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70546203

TC70546303

TC70547201

8BHLE-50E

3

65E

1

50

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70546203

TC70546303

TC70547201

8BHLE-65E

3

3
3
3
3
3
3
3
3

Barrel
Number

Interrupting
Rating rms
(kA Sym.)

Current Rating
(Amperes)

80E

1

50

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70546203

TC70546303

TC70547201

8BHLE-80E

100E

1

50

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70546203

TC70546303

TC70547201

8BHLE-100E

125E

1

50

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70546203

TC70546303

TC70547201

8BHLE-125E

150E

1

50

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70546203

TC70546303

TC70547201

8BHLE-150E

175E

1

50

3.00 (76.2)

15.90 (403.9)

8 (3.63)

TC70546203

TC70546303

TC70547201

8BHLE-175E

200E

2

50

3.00 (76.2)

15.90 (403.9)

17 (7.72)

TC70546403

TC70546503

TC70547201

8BHLE-200E

250E

2

50

3.00 (76.2)

15.90 (403.9)

17 (7.72)

TC70546403

TC70546503

TC70547201

8BHLE-250E

300E

2

50

3.00 (76.2)

15.90 (403.9)

17 (7.72)

TC70546403

TC70546503

TC70547201

8BHLE-300E

350E

2

50

3.00 (76.2)

15.90 (403.9)

17 (7.72)

TC70546403

TC70546503

TC70547201

8BHLE-350E

Fuse Dimensional Details
Approximate Dimensions in Inches (mm)
8BHLE Type Fuse—Single Barrel

8BHLE Type Fuse—Double Barrel
Indicator to be
Located Here

3

3.31
(84.1)

2.12
(53.8)

3
3
3

3.00
(76.2)
Ref.

3

17.88 0.06
(454.2)

17.88 0.06
(454.2)

19.25
Ref.
(488.9)

19.25
Ref.
(488.9)

3
3
3
3
3
3
3
3
3
3
V14-T3-34

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.00
(76.2)
Ref.

2.12
(53.8)

3.4

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

BHLE Type Current Limiting Fuses 15.5 kV Maximum (14.4 kV Nominal), Indoor/Outdoor, Bolt-In

3

Diameter
Length
Approximate Dimensions
in Inches (mm)

Performance Curves
Approximate
Shipping
Minimum
Total
Weight Lbs (kg) Melting Time
Clearing Time

Peak Let-Through
Current

Catalog
Number

3
3

Current Rating
(Amperes)

Barrel
Number

Interrupting
Rating rms
(kA Sym.)

10E

1

63

3.00 (76.2)

18.90 (480.1)

10 (4.54)

TC70548507

TC70548607

TC70548805

15BHLE-10E

15E

1

63

3.00 (76.2)

18.90 (480.1)

10 (4.54)

TC70548507

TC70548607

TC70548805

15BHLE-15E

20E

1

63

3.00 (76.2)

18.90 (480.1)

10 (4.54)

TC70548507

TC70548607

TC70548805

15BHLE-20E

25E

1

63

3.00 (76.2)

18.90 (480.1)

10 (4.54)

TC70548507

TC70548607

TC70548805

15BHLE-25E

30E

1

63

3.00 (76.2)

18.90 (480.1)

10 (4.54)

TC70548507

TC70548607

TC70548805

15BHLE-30E

40E

1

63

3.00 (76.2)

18.90 (480.1)

10 (4.54)

TC70546601

TC70546701

TC70547401

15BHLE-40E

50E

1

63

3.00 (76.2)

18.90 (480.1)

10 (4.54)

TC70546601

TC70546701

TC70547401

15BHLE-50E

65E

1

63

3.00 (76.2)

18.90 (480.1)

10 (4.54)

TC70546601

TC70546701

TC70547401

15BHLE-65E

80E

1

63

3.00 (76.2)

18.90 (480.1)

10 (4.54)

TC70546601

TC70546701

TC70547401

15BHLE-80E

100E

1

63

3.00 (76.2)

18.90 (480.1)

10 (4.54)

TC70546601

TC70546701

TC70547401

15BHLE-100E

125E

1

63

3.00 (76.2)

18.90 (480.1)

10 (4.54)

TC70546601

TC70546701

TC70547401

15BHLE-125E

150E

2

63

3.00 (76.2)

18.90 (480.1)

21 (9.53)

TC70546601

TC70546701

TC70547401

15BHLE-150E

175E

2

63

3.00 (76.2)

18.90 (480.1)

21 (9.53)

TC70546601

TC70546701

TC70547401

15BHLE-175E

200E

2

63

3.00 (76.2)

18.90 (480.1)

21 (9.53)

TC70546601

TC70546701

TC70547401

15BHLE-200E

250E

2

63

3.00 (76.2)

18.90 (480.1)

21 (9.53)

TC70546601

TC70546701

TC70547401

15BHLE-250E

3
3
3
3
3
3
3

15BHLE Type Fuse—Single Barrel

15BHLE Type Fuse—Double Barrel
3.56
(90.4)

3.00
(76.2)
Ref.

3

3

Fuse Dimensional Details
Approximate Dimensions in Inches (mm)

3.00 Ref.
(76.2)

2.12
(53.8)

3

1.53
(38.9)

3
3
3

3.31
(84.1)

20.88 0.06
(530.4)

20.88 0.06
(530.4)

22.25
Ref.
(565.2)

22.25
Ref.
(565.2)

3.00
(76.2)
Ref.

3
2.12
(53.8)

3
3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-35

3.4
3
3

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

HCL Type
HCL Type Current Limiting Fuses 5.5 kV Maximum (4.8 kV Nominal), Indoor
Approximate
Current
Interrupting Diameter
Rating
Barrel Rating rms in Inches
Clip
(Amperes) Number (kA Sym.)
(mm)
Center

Approximate
Shipping
Mounting
Weight Lbs (kg) Type

Live Parts
Performance Curves
(Includes
End Fittings)
Minimum
Total
Peak Let-Through
Catalog Number Melting Time Clearing Time Current

Catalog
Number

10E

1

63

3.00 (76.2)

Clip-lock

9 (4.09)

Non-disconnect

HCL-NL-1

TC70548505

TC70548605

TC70548702

5HCL-10E

15E

1

63

3.00 (76.2)

Clip-lock

9 (4.09)

Non-disconnect

HCL-NL-1

TC70548505

TC70548605

TC70548702

5HCL-15E

20E

1

63

3.00 (76.2)

Clip-lock

9 (4.09)

Non-disconnect

HCL-NL-1

TC70548505

TC70548605

TC70548702

5HCL-20E

25E

1

63

3.00 (76.2)

Clip-lock

9 (4.09)

Non-disconnect

HCL-NL-1

TC70548505

TC70548605

TC70548702

5HCL-25E

30E

1

63

3.00 (76.2)

Clip-lock

9 (4.09)

Non-disconnect

HCL-NL-1

TC70548505

TC70548605

TC70548702

5HCL-30E

3

40E

1

63

3.00 (76.2)

Clip-lock

9 (4.09)

Non-disconnect

HCL-NL-1

TC70545803

TC70545903

TC70547602

5HCL-40E

50E

1

63

3.00 (76.2)

Clip-lock

9 (4.09)

Non-disconnect

HCL-NL-1

TC70545803

TC70545903

TC70547602

5HCL-50E

3

65E

1

63

3.00 (76.2)

Clip-lock

9 (4.09)

Non-disconnect

HCL-NL-1

TC70545803

TC70545903

TC70547602

5HCL-65E

80E

1

63

3.00 (76.2)

Clip-lock

9 (4.09)

Non-disconnect

HCL-NL-1

TC70545803

TC70545903

TC70547602

5HCL-80E

3

100E

1

63

3.00 (76.2)

Clip-lock

9 (4.09)

Non-disconnect

HCL-NL-1

TC70545803

TC70545903

TC70547602

5HCL-100E

125E

1

63

3.00 (76.2)

Clip-lock

9 (4.09)

Non-disconnect

HCL-NL-1

TC70545803

TC70545903

TC70547602

5HCL-125E

150E

1

63

3.00 (76.2)

Clip-lock

9 (4.09)

Non-disconnect

HCL-NL-1

TC70545803

TC70545903

TC70547602

5HCL-150E

200E

1

63

3.00 (76.2)

Clip-lock

10 (4.54)

Non-disconnect

HCL-NL-1

TC70545803

TC70545903

TC70547602

5HCL-200E

250E

1

63

3.00 (76.2)

Clip-lock

10 (4.54)

Non-disconnect

HCL-NL-1

TC70545803

TC70545903

TC70547602

5HCL-250E

3

300E

2

63

3.00 (76.2)

Clip-lock

20 (9.08)

Non-disconnect

HCL-NL-1

TC70546003

TC70516103

TC70547602

5HCL-300E

400E

2

63

3.00 (76.2)

Clip-lock

20 (9.08)

Non-disconnect

HCL-NL-1

TC70546003

TC70516103

TC70547602

5HCL-400E

3

450E

2

63

3.00 (76.2)

Clip-lock

20 (9.08)

Non-disconnect

HCL-NL-1

TC70546003

TC70516103

TC70547602

5HCL-450E

500E

2

63

3.00 (76.2)

Clip-lock

20 (9.08)

Non-disconnect

HCL-NL-1

TC66703401

TC66703501

TC66703701

5HCL-500E

3

600E

2

63

3.00 (76.2)

Clip-lock

20 (9.08)

Non-disconnect

HCL-NL-1

TC66703401

TC66703501

TC66703701

5HCL-600E

750E

3

63

3.00 (76.2)

Bolt-in

30 (13.62)

—

—

TC66703401

TC66703501

TC66703701

5HCL-750E

3

63

3.00 (76.2)

Bolt-in

30 (13.62)

—

—

TC66703401

TC66703501

TC66703701

5BHCL-750E

3

63

3.00 (76.2)

Bolt-in

30 (13.62)

—

—

TC66703401

TC66703501

TC66703701

5HCL-900E

3

63

3.00 (76.2)

Bolt-in

30 (13.62)

—

—

TC66703401

TC66703501

TC66703701

5BHCL-900E

3
3
3
3

3
3

3
3

900E

3
3
3
3

HCL Type Current Limiting Fuses (15.5 kV Maximum, 14.4 kV Nominal), Indoor
Approximate
Current
Interrupting Diameter
Rating
Barrel Rating rms in Inches
Clip
(Amperes) Number (kA Sym.)
(mm)
Center

Approximate
Shipping
Mounting
Weight Lbs (kg) Type

Live Parts
Performance Curves
(Includes
End Fittings)
Minimum
Total
Peak Let-Through
Catalog Number Melting Time Clearing Time Current

Catalog
Number

10E

1

63

3.00 (76.2)

Clip-lock

10 (4.54)

Non-disconnect

HCL-NL-1

TC70548503

TC70548603

TC70548803

15HCL-10E

15E

1

63

3.00 (76.2)

Clip-lock

10 (4.54)

Non-disconnect

HCL-NL-1

TC70548503

TC70548603

TC70548803

15HCL-15E

20E

1

63

3.00 (76.2)

Clip-lock

10 (4.54)

Non-disconnect

HCL-NL-1

TC70548503

TC70548603

TC70548803

15HCL-20E

3

25E

1

63

3.00 (76.2)

Clip-lock

10 (4.54)

Non-disconnect

HCL-NL-1

TC70548503

TC70548603

TC70548803

15HCL-25E

30E

1

63

3.00 (76.2)

Clip-lock

10 (4.54)

Non-disconnect

HCL-NL-1

TC70548503

TC70548603

TC70548803

15HCL-30E

3

40E

1

63

3.00 (76.2)

Clip-lock

10 (4.54)

Non-disconnect

HCL-NL-1

TC66703201

TC66703301

TC70547402

15HCL-40E

50E

1

63

3.00 (76.2)

Clip-lock

10 (4.54)

Non-disconnect

HCL-NL-1

TC66703201

TC66703301

TC70547402

15HCL-50E

65E

1

50

3.00 (76.2)

Clip-lock

12 (5.45)

Non-disconnect

HCL-NL-1

TC66703201

TC66703301

TC70547402

15HCL-65E

80E

1

50

3.00 (76.2)

Clip-lock

12 (5.45)

Non-disconnect

HCL-NL-1

TC66703201

TC66703301

TC70547402

15HCL-80E

100E

1

50

3.00 (76.2)

Clip-lock

12 (5.45)

Non-disconnect

HCL-NL-1

TC66703201

TC66703301

TC70547402

15HCL-100E

3

125E

1

50

3.00 (76.2)

Clip-lock

12 (5.45)

Non-disconnect

HCL-NL-1

TC66703201

TC66703301

TC70547402

15HCL-125E

150E

2

50

3.00 (76.2)

Clip-lock

24 (10.90)

Non-disconnect

HCL-NL-1

TC66703201

TC66703301

TC70547402

15HCL-150E

3

200E

2

50

3.00 (76.2)

Clip-lock

24 (10.90)

Non-disconnect

HCL-NL-1

TC66703201

TC66703301

TC70547402

15HCL-200E

250E

2

50

3.00 (76.2)

Clip-lock

24 (10.90)

Non-disconnect

HCL-NL-1

TC66703201

TC66703301

TC70547402

15HCL-250E

300E

2

50

3.00 (76.2)

Clip-lock

24 (10.90)

Non-disconnect

HCL-NL-1

TC66703201

TC66703301

TC70547402

15HCL-300E

3

3
3

3
3
3

V14-T3-36

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.4

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

Fuse Dimensional Details
Approximate Dimensions in Inches (mm)

3

HCL-14 Type Fuse
Indicator Flush with Surface
in Untripped Position

5.5 and 15.5 kV Clip Lock Mounted
Number
of
Barrels

Ampere
Rating

Figure
Number

A

B

C

A

Interrupting
Rating rms
(kA Sym.)

C

4.31
(109.5)

5.5 kV Maximum—Clip Lock Style—15.25-Inch (387.4 mm)
Clip Centers—3.00-Inch (76.2 mm) Barrel Diameter
10E–150E

1

A

16.81 (427.0)



16.12 (409.4)

1.25
(31.8)

1.25
(31.8)

63

200E–600E

1

A

22.81 (579.4)



22.12 (561.8)

A

B

C

7.94
(201.7)
1.25
(31.8)

65E–125E

1

A

22.81 (579.4)

22.12 (561.8)



63

150E–300E

2

B

22.81 (579.4)

22.12 (561.8)



50

A

19.81 (503.2)



19.12 (485.6)

B
D

Number
of
Barrels

Figure
Number

B

C

D

3

C

25.11
(637.8)

22.37
(568.2)

23.73
(602.7)



3

3.00
(76.2)

3

0.44 x 0.91
Slots
(11.2 x 23.1)
C

63

3
3

A

Interrupting
Rating rms
(kA Sym.)

5.5 kV Maximum—Bolt-in Style—23.73-Inch (602.7 mm)
Hole Centers—3.00-Inch (76.2 mm) Barrel Diameter
750E,
900E

3

Indicator Flush with Surface
in Untripped Position
Blown Fuse Indicator

11.62
(295.1)

1.50
(38.1)

A

0.25
(6.4)

63

Bolt-In Series—5.5 kV
Ampere
Rating

1.25
(31.8)
Figure B

15.5 kV Maximum—Clip Lock Style—18.25-Inch (463.6 mm)
Clip Centers—3.00-Inch (76.2 mm) Barrel Diameter
1

3
3

Interrupting
Rating rms
(kA Sym.)

15.5 kV Maximum—Clip Lock Style—21.25-Inch (539.8 mm)
Clip Centers—3.00-Inch (76.2 mm) Barrel Diameter

10E–50E

3

B

15.5 kV Clip Lock Mounted
Figure
Number

3

Blown Fuse Indicator

C

Ampere
Rating

3

Indicator Flush with Surface
in Untripped Position

63
A

Number
of
Barrels

0.25
(6.4)
3.00
(76.2)

Figure A

5.5 kV Maximum—Clip Lock Style—21.25-Inch (539.8 mm)
Clip Centers—3.00-Inch (76.2 mm) Barrel Diameter

3

Blown Fuse Indicator

B

3

3

0.38
(9.7)

3

3.00
(76.2)

3

1.50
(38.1)
0.44
Dia. Hole
(11.2)

3

Figure C

3

HCL Type Fuse

3

16.38 (416.1) 0.06 for HCL-8
19.38 (492.3) 0.06 for HCL-15

3
3
3

Note
 0.5 (12.7) tripped force 2 lb (0.9 kg).

3
3
3
3
3
3
3
3
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-37

3.4
3
3

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

Mounting Details
Approximate Dimensions in Inches (mm)
CLE and HLE Type Disconnect Type Mountings

3

G

3
3

F

D

E

3
3
3
3
3
3

C

A

3
3
3
3
3
3
3

E

D

B

3
3
3
3
3
3
3
3
3
3
3
3
V14-T3-38

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.4

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

Approximate Dimensions in Inches (mm)

3

CLE and HLE Type Disconnect Mounting—Single
Catalog
Number

Hole Centers
A

Hole Centers
B

Overall Length
C

Hole Inset
D

Hole Centers
E

Contact Height
F

Overall Height
G

BIL
Rating

2CLE-GDM-C

9.37 (238.0)

6.00 (152.4)

22.13 (562.1)

0.75 (19.0)

1.75 (44.4)

4.50 (114.3)

9.75 (247.6)

60

2CLE-GDM-D

8.24 (209.3)

6.00 (152.4)

18.00 (457.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

11.72 (297.7)

60

2CLE-PDM-C

9.37 (238.0)

6.00 (152.4)

22.13 (562.1)

0.75 (19.0)

1.75 (44.4)

4.50 (114.3)

9.75 (247.6)

60

2CLE-PDM-D

8.24 (209.3)

6.00 (152.4)

18.00 (457.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

11.72 (297.7)

60

5CLE-GDM-C

12.74 (323.6)

6.00 (152.4)

25.50 (647.7)

0.75 (19.0)

1.75 (44.4)

4.50 (114.3)

9.75 (247.6)

60

5CLE-PDM-C

12.74 (323.6)

6.00 (152.4)

25.50 (647.7)

0.75 (19.0)

1.75 (44.4)

4.50 (114.3)

9.75 (247.6)

60

5CLE-GDM-D

15.24 (387.1)

6.00 (152.4)

25.00 (647.7)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

11.72 (297.7)

60

5CLE-PDM-D

15.24 (387.1)

6.00 (152.4)

25.00 (647.7)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

11.72 (297.7)

60

5HLE-GDM-D

16.25 (412.8)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

11.72 (297.7)

60

5HLE-PDM-D

16.25 (412.8)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

11.72 (297.7)

60

8CLE-GDM-C

15.24 (387.1)

6.00 (152.4)

28.00 (711.2)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

12.37 (314.2)

75

8CLE-GDM-D

15.24 (387.1)

6.00 (152.4)

25.00 (647.7)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

14.22 (361.2)

75

8CLE-PDM-C

15.24 (387.1)

6.00 (152.4)

28.00 (711.2)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

12.37 (314.2)

75

8CLE-PDM-C

15.24 (387.1)

6.00 (152.4)

25.00 (647.7)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

14.22 (361.2)

75

8HLE-GDM-D

16.25 (412.8)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

11.72 (297.7)

75

8HLE-PDM-D

16.25 (412.8)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

11.72 (297.7)

75

15CLE-GDM-C

21.24 (539.5)

6.00 (152.4)

34.00 (863.6)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

12.37 (314.2)

95

15CLE-GDM-D

21.15 (537.2)

6.00 (152.4)

31.00 (787.4)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

14.22 (361.2)

95

15CLE-PDM-C

21.24 (539.5)

6.00 (152.4)

34.00 (863.6)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

12.37 (314.2)

95

15CLE-PDM-D

21.15 (537.2)

6.00 (152.4)

31.00 (787.4)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

14.22 (361.2)

95

15CLE-HPDM-C

21.24 (539.5)

6.00 (152.4)

34.00 (863.6)

0.75 (19.0)

1.75 (44.4)

8.50 (215.9)

13.87 (352.3)

110

15CLE-HPDM-D

21.15 (537.2)

6.00 (152.4)

31.00 (787.4)

0.62 (15.7)

1.75 (44.4)

8.50 (215.9)

13.87 (352.3)

110

15HLE-GDM-D

16.25 (412.8)

6.00 (152.4)

25.00 (647.7)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

14.22 (361.2)

95

15HLE-PDM-D

16.25 (412.8)

6.00 (152.4)

25.00 (647.7)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

14.22 (361.2)

95

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

CLE and HLE Type Non-Disconnect Mounting—Double
Catalog
Number

Hole Centers
A

Hole Centers
B

Overall Length
C

Hole Inset
D

Hole Centers
E

Contact Height
F

Overall Height
G

BIL
Rating

2CLE-GDM-E

8.24 (209.3)

6.00 (152.4)

18.00 (457.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

15.28 (388.1)

60

2CLE-PDM-E

8.24 (209.3)

6.00 (152.4)

18.00 (457.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

15.28 (388.1)

60

5CLE-GDM-E

15.24 (387.1)

6.00 (152.4)

25.00 (647.7)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

15.28 (388.1)

60

5CLS-PDM-E

15.24 (387.1)

6.00 (152.4)

25.00 (647.7)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

15.28 (388.1)

60

5HLE-GDM-E

16.25 (412.8)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

15.28 (388.1)

60

5HLE-PDM-E

16.25 (412.8)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

15.28 (388.1)

60

8CLE-GDM-E

15.24 (387.1)

6.00 (152.4)

25.00 (647.7)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

17.78 (451.6)

75

8CLE-PDM-E

15.24 (387.1)

6.00 (152.4)

25.00 (647.7)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

17.78 (451.6)

75

8HLE-GDM-E

16.25 (412.8)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

17.78 (451.6)

75

8HLE-PDM-E

16.25 (412.8)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

17.78 (451.6)

75

15CLE-PDM-E

21.15 (537.2)

6.00 (152.4)

31.00 (787.4)

0.62 (15.7)

1.75 (44.4)

8.50 (215.9)

19.28 (489.7)

95

15HLE-GDM-E

16.25 (412.8)

6.00 (152.4)

26.00 (660.4)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

17.78 (451.6)

95

15HLE-PDM-E

16.25 (412.8)

6.00 (152.4)

26.00 (660.4)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

17.78 (451.6)

95

3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-39

3.4

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

3

Approximate Dimensions in Inches (mm)

3

CLE and HLE Type Non-Disconnect Mountings
G

3

F

D

3
E

3
3
3
3
3
3

A

C

3
3
3
3
3
3

E

3
3

D

B

3
3
3
3
3
3
3
3
3
3
3
3
V14-T3-40

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.4

Current Limiting Fuses
CLE, HLE, LHLE, AHLE, BHLE, HCL and BHCL Type Fuses

Approximate Dimensions in Inches (mm)

3

CLE and HLE Type Non-Disconnect Mounting—Single
Catalog
Number

Hole Centers
A

Hole Centers
B

Overall Length
C

Hole Inset
D

Hole Centers
E

Contact Height
F

Overall Height
G

BIL
Rating

2CLE-GNM-C

9.37 (238.0)

6.00 (152.4)

18.63 (473.2)

0.75 (19.0)

1.75 (44.4)

4.50 (114.3)

7.25 (184.1)

60

2CLE-PNM-C

9.37 (238.0)

6.00 (152.4)

18.63 (473.2)

0.75 (19.0)

1.75 (44.4)

4.50 (114.3)

7.25 (184.1)

60

2CLE-GNM-D

8.24 (209.3)

6.00 (152.4)

18.00 (457.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

8.79 (223.3)

60

2CLE-PNM-D

8.24 (209.3)

6.00 (152.4)

18.00 (457.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

8.79 (223.3)

60

5CLE-GNM-C

12.75 (323.8)

6.00 (152.4)

22.00 (558.8)

0.75 (19.0)

1.75 (44.4)

4.50 (114.3)

7.25 (184.1)

60

5CLE-PNM-C

12.75 (323.8)

6.00 (152.4)

22.00 (558.8)

0.75 (19.0)

1.75 (44.4)

4.50 (114.3)

7.25 (184.1)

60

5CLE-GNM-D

15.24 (387.1)

6.00 (152.4)

25.00 (635.0)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

8.79 (223.3)

60

5CLE-PNM-D

15.24 (387.1)

6.00 (152.4)

25.00 (635.0)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

8.79 (223.3)

60

5HLE-GNM-D

16.25 (412.7)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

8.79 (223.3)

60

15HLE-PNM-D

16.25 (412.7)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

8.79 (223.3)

60

8CLE-GNM-C

15.25 (387.3)

6.00 (152.4)

24.50 (622.3)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

9.75 (247.6)

75

8CLE-PNM-C

15.25 (387.3)

6.00 (152.4)

24.50 (622.3)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

9.75 (247.6)

75

8CLE-PNM-D

15.25 (387.3)

6.00 (152.4)

25.00 (635.0)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

11.29 (286.7)

75

8CLE-PNM-D

15.25 (387.3)

6.00 (152.4)

25.00 (635.0)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

11.29 (286.7)

75

8HLE-GNM-D

16.25 (412.7)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

11.29 (286.7)

75

8HLE-PNM-D

16.25 (412.7)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

11.29 (286.7)

75

15CLE-GNM-C

21.25 (539.7)

6.00 (152.4)

30.50 (774.7)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

9.75 (247.6)

95

15CLE-PNM-C

21.25 (539.7)

6.00 (152.4)

30.50 (774.7)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

9.75 (247.6)

95

15CLE-HPMN-C

21.25 (539.7)

6.00 (152.4)

30.50 (774.7)

0.75 (19.0)

1.75 (44.4)

8.50 (215.9)

11.25 (285.7)

110

15CLE-GNM-D

21.15 (539.7)

6.00 (152.4)

31.00 (787.4)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

11.29 (286.7)

95

15CLE-PNM-D

21.15 (539.7)

6.00 (152.4)

31.00 (787.4)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

11.29 (286.7)

95

15CLE-HPNM-D

21.15 (539.7)

6.00 (152.4)

31.00 (787.4)

0.62 (15.7)

1.75 (44.4)

8.50 (215.9)

12.79 (286.7)

110

15HLE-GNM-D

16.25 (412.7)

6.00 (152.4)

26.00 (660.4)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

11.29 (286.7)

95

15HLE-PNM-D

16.25 (412.7)

6.00 (152.4)

26.00 (660.4)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

11.29 (286.7)

95

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

CLE and HLE Type Non-Disconnect Mounting—Double
Catalog
Number

Hole Centers
A

Hole Centers
B

Overall Length
C

Hole Inset
D

Hole Centers
E

Contact Height
F

Overall Height
G

BIL
Rating

2CLE-GNM-E

8.24 (209.3)

6.00 (152.4)

18.00 (457.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

12.48 (317.0)

60

2CLE-PNM-E

8.24 (209.3)

6.00 (152.4)

18.00 (457.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

12.48 (317.0)

60

5CLE-GNM-E

15.24 (387.1)

6.00 (152.4)

25.00 (635.0)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

12.48 (317.0)

60

5HLE-PNM-E

15.24 (387.1)

6.00 (152.4)

25.00 (635.0)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

12.48 (317.0)

60

5HLE-GNM-E

16.25 (412.7)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

12.48 (317.0)

60

5HLE-PNM-E

16.25 (412.7)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

4.50 (114.3)

12.48 (317.0)

60

8CLE-GNM-E

15.24 (387.1)

6.00 (152.4)

25.00 (635.0)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

14.98 (380.5)

75

8CLE-PNM-E

15.24 (387.1)

6.00 (152.4)

25.00 (635.0)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

14.98 (380.5)

75

8HLE-GNM-E

16.25 (412.7)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

14.98 (380.5)

75

8HLE-PNM-E

16.25 (412.7)

6.00 (152.4)

23.00 (584.2)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

14.98 (380.5)

75

15CLE-PNM-E

21.15 (539.7)

6.00 (152.4)

31.00 (787.4)

0.62 (15.7)

1.75 (44.4)

8.50 (215.9)

16.48 (418.5)

95

15HLE-GNM-E

16.25 (412.7)

6.00 (152.4)

26.00 (660.4)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

14.98 (380.5)

95

15HLE-PNM-E

16.25 (412.7)

6.00 (152.4)

26.00 (660.4)

0.62 (15.7)

1.75 (44.4)

7.00 (177.8)

14.98 (380.5)

95

3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-41

3.5
3

Current Limiting Fuses
CLPT and NCLPT Type Fuses

Contents

(N)CLPT Fuses

Description

3

CLPT and NCLPT Type Fuses
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Mounting Details. . . . . . . . . . . . . . . . . . . . . . . .

3
3
3
3
3
3
3
3
3

CLPT and NCLPT Type Fuses

3

Product Description

3
3
3
3
3
3
3
3
3
3

Eaton CLPT (indicating) and
NCLPT (non-indicating) fuses
are applied wherever it is
necessary to limit the shortcircuit currents on control
transformer and potential
transformer circuits in high
capacity systems in industrial
installations and commercial
buildings.

Features
CLPT and NCLPT type
current limiting fuses offer a
number of desirable
advantages. Consider the
following during the selection
process:
●

3
3
3
3

●

Current ratings from 1/2E to
10E are available at 2.4 kV to
34.5 kV.

3
3

Ratings and Selection
●

●

Quiet Safe Operation:
These fuses are designed
for silent operation and
elimination of flame
discharges when the fuse
operates
Identification of Blown
Fuse: These fuses are
available in indicating and
non-indicating versions.
Indicators protrude from
indicating type fuses
providing a visual indication
of a blown fuse

3
3
V14-T3-42

●

●

Space Economy: Because
the fuse is designed to
eliminate flame and gas
discharges, no exhaust
control devices, flame
boxes, vents or reinforcing
are required
Complete Protection
Provided: Current limiting
fuses provide positive
interruption even on low
fault currents. The fuse
limits the magnitude of
electromechanical stresses
in the apparatus to be
protected
Mountings: Disconnect
and non-disconnect
mountings are available for
most types of fuses from
5 kV through 15 kV. Live
parts are available for
23 kV and 34.5 kV fuses
Dimensions: Various fuse
sizes are available for a
wide range of applications

Construction
CLPT type current limiting
fuses are basically
constructed in a similar
fashion to other Eaton current
limiting fuses.

When a decision has been
made to use current limiting
fuses, the minimum amount
of information required to
make the proper selection is:
●
●
●
●

Voltage rating
Current rating
Interrupting rating
Mounting method
●
Non-disconnect
mounting
●
Disconnect mounting
●
Live parts only
●
No required mounting

Refer to tables on Pages
V14-T3-43 to V14-T3-49 for
assistance in selecting the
correct fuse catalog number.
These types of fuses are
used in conjunction with
potential and control power
transformers. There are
specific rules governing the
selection of the required fuse
continuous rating. The
current limiting fuse
application notes earlier in
this publication offer
additional information about
this type of application.
When selecting the
appropriate fuse for a new
installation, keep in mind that
one fuse unit and one
compatible mounting may be
required for each phase.

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Page
V14-T3-43
V14-T3-43
V14-T3-48

3.5

Current Limiting Fuses
CLPT and NCLPT Type Fuses

Catalog Number Selection

3
3

CLPT Fuse Units

15 CLPT - 5E - A
Maximum kV
2 = 2.75 kV
5 = 5.5 kV
8 = 8.3 kV
15 = 15.5 kV
25 = 25.8 kV
38 = 38 kV

Ampere
Rating
0.5E
1E
1.5E
2E
3E
4E
5E
8E
10E

Type
CLPT
NCLPT

3
3

Dimensions
A = Shorter length
B = Longer length

3
3
3
3
3

CLPT Mounting

3

15 CLPT - P NM - A
Maximum kV
2 = 2.75 kV
5 = 5.5 kV
8 = 8.3 kV
15 = 15.5 kV
25 = 25.8 kV
38 = 38 kV

Insulator
G = Glass polyester
P = Porcelain

Type
CLPT

3
3

Dimensions
A = Shorter length
B = Longer length

Hardware
DF = Disconnect end fittings
DL = Disconnect live parts
DM = Disconnect mounting
NL = Non-disconnect live parts
NM = Non-disconnect mounting

3
3
3
3

Product Selection

3

CLPT Type

Indicating

3
3

CLPT Type Current Limiting Fuses 2.475 kV Maximum (2.4 kV Nominal)
Clip
Center

Performance Curves

Current
Rating
(Amperes)

Interrupting
Rating
rms (kA Sym.)

Diameter

Length

Approximate
Shipping
Approximate Dimensions in Inches (mm) Weight Lbs (kg)

Minimum
Melting Time

Total
Clearing Time

Peak LetThrough
Current

Catalog
Number

0.25E

63

0.81 (20.6)

—

4.50 (114.3)

0.25 (0.11)

TC56357202

TC59883702

TC63933702

2NCLPT-.25E

0.5E

63

0.81 (20.6)

—

4.50 (114.3)

0.25 (0.11)

TC56357202

TC59883702

TC63933702

2NCLPT-.5E

1E

40

0.81 (20.6)

—

4.50 (114.3)

0.25 (0.11)

TC56357202

TC59883702

TC63933702

2NCLPT-1E

2E

40

0.81 (20.6)

—

4.50 (114.3)

0.25 (0.11)

TC56357202

TC59883702

TC63933702

2NCLPT-2E

5E

25

0.81 (20.6)

—

4.50 (114.3)

0.25 (0.11)

TC56357202

TC59883702

TC63933702

2NCLPT-5E

3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-43

3.5

CLPT and NCLPT Type Fuses

CLPT Type Current Limiting Fuses 5.5 kV Maximum (4.8 kV Nominal)

3

Current
Rating
(Amperes)

3
3

Current Limiting Fuses

Non-Indicating

Interrupting
Rating
rms (kA Sym.)

Diameter

Clip
Center

Performance Curves
Length

Approximate
Shipping
Approximate Dimensions in Inches (mm) Weight Lbs (kg)

Peak LetMinimum
Total
Through
Melting Time Clearing Time Current

Catalog
Number

Non-Indicating

3

0.5E

63

0.81 (20.6)

—

5.63 (143.0)

0.25 (0.11)

TC66702402

TC66702502

TC66704101

5NCLPT-.5E

1E

63

0.81 (20.6)

—

5.63 (143.0)

0.25 (0.11)

TC66702402

TC66702502

TC66704101

5NCLPT-1E

3

2E

63

0.81 (20.6)

—

5.63 (143.0)

0.25 (0.11)

TC66702402

TC66702502

TC66704101

5NCLPT-2E

3E

63

0.81 (20.6)

—

5.63 (143.0)

0.25 (0.11)

TC66702402

TC66702502

TC66704101

5NCLPT-3E

4E

63

0.81 (20.6)

—

5.63 (143.0)

0.25 (0.11)

TC66702402

TC66702502

TC66704101

5NCLPT-4E

5E

63

0.81 (20.6)

—

5.63 (143.0)

0.25 (0.11)

TC66702402

TC66702502

TC66704101

5NCLPT-5E

0.5E

50

1.00 (25.4)

—

5.63 (143.0)

0.25 (0.11)

TC66702402

TC66702502

TC66704101

317B487H02

3

1E

50

1.00 (25.4)

—

5.63 (143.0)

0.25 (0.11)

TC66702402

TC66702502

TC66704101

317B487H06

2E

50

1.00 (25.4)

—

5.63 (143.0)

0.25 (0.11)

TC66702402

TC66702502

TC66704101

317B487H03

3

3E

50

1.00 (25.4)

—

5.63 (143.0)

0.25 (0.11)

TC66702402

TC66702502

TC66704101

317B487H04

3
3

5E

50

1.00 (25.4)

—

5.63 (143.0)

0.25 (0.11)

TC66702402

TC66702502

TC66704101

317B487H05

0.5E

63

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.2 (0.54)

TC70548302

TC70548402

TC63934002

5NCLPT-.5E-A

1E

63

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.2 (0.54)

TC70548302

TC70548402

TC63934002

5NCLPT-1E-A

2E

63

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.2 (0.54)

TC70548302

TC70548402

TC63934002

5NCLPT-2E-A

3

3E

63

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.2 (0.54)

TC70548302

TC70548402

TC63934002

5NCLPT-3E-A

5E

63

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.2 (0.54)

TC70548302

TC70548402

TC63934002

5NCLPT-5E-A

3

10E

63

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.2 (0.54)

TC70548302

TC70548402

TC63934002

5NCLPT-10E-A

0.5E

80

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.2 (0.54)

TC56353206

TC56353306

TC63934001

5CLPT-.5E

3

1E

80

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.2 (0.54)

TC56353206

TC56353306

TC63934001

5CLPT-1E

1.5E

80

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.2 (0.54)

TC56353206

TC56353306

TC63934001

5CLPT-1.5E

3

3E

80

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.2 (0.54)

TC56353206

TC56353306

TC63934001

5CLPT-3E

5E

80

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.2 (0.54)

TC56353206

TC56353306

TC63934001

5CLPT-5E

10E

80

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.2 (0.54)

TC56353206

TC56353306

TC63934001

5CLPT-10E

3
3

Indicating

3

3

Indicating

3
CLPT Type Mountings and Hardware 5.5 kV Maximum (4.8 kV Nominal) 

3
3
3
3

Fuse Mounting
Type 

Voltage
BIL (kV)

Catalog Number

Catalog Number

0.5–2

Non-disconnect

60

5CLPT-PNM-A

5CLPT-GNM-A

CLPT-NL

—

Disconnect

60

5CLPT-PDM-A

5CLPT-GDM-A

CLPT-DL

CLPT-DF

Non-disconnect

60

5CLPT-PNM-B

5CLPT-GNM-B

CLPT-NL

—

Disconnect

60

5CLPT-PDM-B

5CLPT-GDM-B

CLPT-DL

CLPT-DF

Notes
 Refers only to 5CLPT and 5NCLPT-A fuses only.
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3
3
3
3
3
3
3
V14-T3-44

End Fittings
(Disconnect Only)

Ampere
Rating

3–10

3

Live Parts
(Including End Fittings) 

Mounting
(Including Live Parts, End Fittings) 
Porcelain Insulator
Glass-Polyester Insulator
Catalog Number
Catalog Number

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.5

Current Limiting Fuses
CLPT and NCLPT Type Fuses

CLPT Type Current Limiting Fuses 8.3 kV Maximum (7.2 kV Nominal)
Current
Rating
(Amperes)
Non-Indicating

Indicating

Interrupting
Rating
rms (kA Sym.)

Diameter

Clip
Center

3

Performance Curves
Length

Approximate Dimensions in Inches (mm)

Approximate
Shipping
Weight Lbs (kg)

Peak LetMinimum
Total
Through
Melting Time Clearing Time Current

Catalog
Number

3
3

Non-Indicating
2E

25

0.81 (20.6)

—

8.00 (203.2)

0.25 (0.11)

TC56357206

TC59883706

TC63933704

8NCLPT-2E

4E

25

0.81 (20.6)

—

8.00 (203.2)

0.25 (0.11)

TC56357206

TC59883706

TC63933704

8NCLPT-4E

10E

50

1.10 (27.9)

—

5.00 (127.0)

0.5 (0.23)

TC56357206

TC59883706

TC63933704

8NCLPT-0E

1E

50

1.10 (27.9)

—

5.00 (127.0)

0.5 (0.23)

TC56357206

TC59883706

TC63933704

8NCLPT-1E

5E

50

1.10 (27.9)

—

5.00 (127.0)

0.5 (0.23)

TC56357206

TC59883706

TC63933704

8NCLPT-5E

0.5E

50

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.5 (0.70)

TC70548303

TC70548403

TC63934002

8NCLPT-.5E-A

1E

50

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.5 (0.70)

TC70548303

TC70548403

TC63934002

8NCLPT-1E-A

2E

50

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.5 (0.70)

TC70548303

TC70548403

TC63934002

8NCLPT-2E-A

3E

50

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.5 (0.70)

TC70548303

TC70548403

TC63934002

8NCLPT-3E-B

5E

50

1.60 (40.6)

11.50 (292.1) 12.90 (327.7)

1.6 (0.73)

TC70548303

TC70548403

TC63934002

8NCLPT-5E-B

10E

50

1.60 (40.6)

11.50 (292.1) 12.90 (327.7)

1.6 (0.73)

TC70548303

TC70548403

TC63934002

8NCLPT-10E-B

.5E

80

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.5 (0.70)

TC56353206

TC56353306

TC63934001

8CLPT-.5E

3E

80

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.6 (0.73)

TC56353206

TC56353306

TC63934001

8CLPT-3E

3
3
3
3
3
3
3

Indicating

5E

50

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.6 (0.73)

TC56353206

TC56353306

TC63934001

8CLPT-5E

10E

50

1.60 (40.6)

8.10 (205.7)

9.50 (241.3)

1.6 (0.73)

TC56353206

TC56353306

TC63934001

8CLPT-10E

3
3
3

CLPT Type Mountings and Hardware 8.3 kV Maximum (7.2 kV Nominal)

Ampere
Rating
0.5–2

3–10

3



Live Parts
(Including End Fittings) 

End Fittings
(Disconnect Only)

Voltage
BIL (kV)

Mounting
(Including Live Parts, End Fittings) 
Porcelain Insulator
Glass-Polyester Insulator
Catalog Number
Catalog Number

Catalog Number

Catalog Number

Non-disconnect

75

8CLPT-PNM-A

8CLPT-GNM-A

CLPT-NL

—

Disconnect

75

8CLPT-PDM-A

8CLPT-GDM-A

CLPT-DL

CLPT-DF

Non-disconnect

75

8CLPT-PNM-B

8CLPT-GNM-B

CLPT-NL

—

Disconnect

75

8CLPT-PDM-B

8CLPT-GDM-B

CLPT-DL

CLPT-DF

Fuse Mounting
Type 

3
3
3

Notes
 Refers only to 8CLPT and 8NCLPT-A or -B fuses only.
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3
3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-45

3.5

CLPT and NCLPT Type Fuses

CLPT Type Current Limiting Fuses 15.5 kV Maximum (7.2 kV Nominal)

3

Current
Rating
(Amperes)

3
3

Current Limiting Fuses

Non-Indicating

Interrupting
Rating
rms (kA Sym.)

Diameter

Clip
Center

Performance Curves
Length

Approximate Dimensions in Inches (mm)

Approximate
Shipping
Weight Lbs (kg)

Peak LetMinimum
Total
Through
Melting Time Clearing Time Current

Catalog
Number

Non-Indicating

3

0.5E

63

1.60 (40.6)

11.50 (292.1)

12.90 (327.7)

1.6 (0.73)

TC70548303

TC70548403

TC63934002

15NCLPT-.5E

1E

63

1.60 (40.6)

11.50 (292.1)

12.90 (327.7)

1.6 (0.73)

TC70548303

TC70548403

TC63934002

15NCLPT-1E

3

2E

63

1.60 (40.6)

11.50 (292.1)

12.90 (327.7)

1.6 (0.73)

TC70548303

TC70548403

TC63934002

15NCLPT-1.5E

3E

63

1.60 (40.6)

16.10 (408.9)

17.60 (447.0)

2 (0.91)

TC70548303

TC70548403

TC63934002

15NCLPT-3E

5E

63

1.60 (40.6)

16.10 (408.9)

17.60 (447.0)

2 (0.91)

TC70548303

TC70548403

TC63934002

15NCLPT-5E

10E

63

1.60 (40.6)

16.10 (408.9)

17.60 (447.0)

2 (0.91)

TC70548303

TC70548403

TC63934002

15NCLPT-10E

3
3

Indicating

Indicating

3

0.5E

80

1.60 (40.6)

11.50 (292.1)

12.90 (327.7)

1.6 (0.73)

TC56353206

TC56353306

TC63934001

15CLPT-.5E

1E

80

1.60 (40.6)

11.50 (292.1)

12.90 (327.7)

1.6 (0.73)

TC56353206

TC56353306

TC63934001

15CLPT-1E

3

2E

80

1.60 (40.6)

11.50 (292.1)

12.90 (327.7)

1.6 (0.73)

TC56353206

TC56353306

TC63934001

15CLPT-1.5E

3E

80

1.60 (40.6)

16.10 (408.9)

17.60 (447.0)

2 (0.91)

TC56353206

TC56353306

TC63934001

15CLPT-3E

5E

80

1.60 (40.6)

16.10 (408.9)

17.60 (447.0)

2 (0.91)

TC56353206

TC56353306

TC63934001

15CLPT-5E

10E

50

1.60 (40.6)

16.10 (408.9)

17.60 (447.0)

2 (0.91)

TC56353206

TC56353306

TC63934001

15CLPT-10E

3
3
3

CLPT Type Mountings and Hardware 15.5 kV Maximum (14.4 kV Nominal)
Live Parts
(Including End Fittings) 

End Fittings
(Disconnect Only)

Voltage
BIL (kV)

Mounting
(Including Live Parts, End Fittings) 
Porcelain Insulator
Glass-Polyester Insulator
Catalog Number
Catalog Number

Catalog Number

Catalog Number
—

3
3

Ampere
Rating

3

0.5–2

3

3–10

3

Fuse Mounting
Type 
Non-disconnect

95

15CLPT-PNM-A

15CLPT-GNM-A

CLPT-NL

Disconnect

95

15CLPT-PDM-A

15CLPT-GDM-A

CLPT-DL

CLPT-DF

Non-disconnect

95

15CLPT-PNM-B

15CLPT-GNM-B

CLPT-NL

CLPT-DF

Disconnect

95

15CLPT-PDM-B

15CLPT-GDM-B

CLPT-DL

—

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3
3
3
3
3
3
3
3
3
3
3
3
3
V14-T3-46

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.5

Current Limiting Fuses
CLPT and NCLPT Type Fuses

CLPT Type Current Limiting Fuses 25.5 kV Maximum (23.0 kV Nominal)

3

Current
Rating
(Amperes)

Interrupting
Rating
rms (kA Sym.)

Clip
Diameter
Center
Length
Approximate Dimensions in Inches (mm)

Approximate
Shipping
Weight Lbs (kg)

Performance Curves
Minimum
Total
Melting Time
Clearing Time

Peak Let-Through
Current

Catalog
Number

3

0.5E

44

1.60 (40.6)

16.10 (408.9)

17.60 (447.0)

2 (0.91)

TC56353208

TC56353308

TC63933901

25CLPT-.5E

1E

44

1.60 (40.6)

16.10 (408.9)

17.60 (447.0)

2 (0.91)

TC56353208

TC56353308

TC63933901

25CLPT-1E

3
3

CLPT Type Mountings and Hardware 25.5 kV Maximum (23.0 kV Nominal)
Live Parts
(Including End Fittings) 

End Fittings
(Disconnect Only)

Ampere
Rating

Fuse Mounting
Type 

Voltage
BIL (kV)

Mounting
(Including Live Parts, End Fittings) 
Porcelain Insulator
Glass-Polyester Insulator
Catalog Number
Catalog Number

Catalog Number

Catalog Number

0.5E–1E

Non-disconnect

150

25CLPT-PNM-A

—

25CLPT-NL

—

Disconnect

150

25CLPT-PDM-A

—

25CLPT-DL

CLPT-DF

3
3
3

Current
Rating
(Amperes)

Interrupting
Rating
rms (kA Sym.)

Clip
Diameter
Center
Length
Approximate Dimensions in Inches (mm)

Approximate
Shipping
Weight Lbs (kg)

Performance Curves
Minimum
Total
Melting Time
Clearing Time

Peak Let-Through
Current

Catalog
Number

0.5E

44

1.60 (40.6)

2 (0.91)

TC56353208

TC63933901

38CLPT-.5E

18.60 (472.4)

3
3

CLPT Type Current Limiting Fuses 38.0 kV Maximum (34.5 kV Nominal)

17.10 (434.3)

3

TC56353308

3
3
3

CLPT Type Mountings and Hardware 38.0 kV Maximum (34.5 kV Nominal)

Ampere
Rating

Fuse Mounting
Type 

Voltage
BIL (kV)

Mounting
(Including Live Parts, End Fittings) 
Porcelain Insulator
Glass-Polyester Insulator
Catalog Number
Catalog Number

Live Parts
(Including End Fittings) 

End Fittings
(Disconnect Only)

Catalog Number

Catalog Number

0.5E

Disconnect

—

Not applicable

Not applicable

25CLPT-NL

CLPT-DF

Non-disconnect

—

Not applicable

Not applicable

25CLPT-DL

—

3
3
3
3

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3
3
3
3
3
3
3
3
3
3
3
3
3
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-47

3.5
3
3

Current Limiting Fuses
CLPT and NCLPT Type Fuses

Mounting Details
Approximate Dimensions in Inches (mm)
CLPT and NCLPT Type Disconnect Mountings

3

G

3
3

F

D

E

3
3
3
3
3
3

C

A

3
3
3
3
3
3
3

E

D

B

3
3

Catalog
Number

Hole Centers
A

Hole Centers
B

Overall Length
C

Hole Inset
D

Hole Centers
E

Contact Height
F

Overall Height
G

BIL
Rating

3

5CLPT-GDM-A

9.37 (238.0)

6.00 (152.4)

18.63 (473.2)

0.75 (19.0)

1.75 (44.4)

4.50 (114.3)

9.56 (242.8)

60

5CLPT-PDM-A

9.37 (238.0)

6.00 (152.4)

18.63 (473.2)

0.75 (19.0)

1.75 (44.4)

4.50 (114.3)

9.56 (242.8)

60

8CLPT-GDM-A

9.37 (238.0)

6.00 (152.4)

18.63 (473.2)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

12.06 (306.3)

75

8CLPT-GDM-B

9.37 (238.0)

6.00 (152.4)

18.63 (473.2)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

12.06 (306.3)

75

8CLPT-PDM-A

12.74 (323.6)

6.00 (152.4)

22.00 (558.8)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

12.06 (306.3)

75

3

8CLPT-PDM-B

12.74 (323.6)

6.00 (152.4)

22.00 (558.8)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

12.06 (306.3)

75

15CLPT-GDM-A

12.74 (323.6)

6.00 (152.4)

22.00 (558.8)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

12.06 (306.3)

95

3

15CLPT-PDM-A

12.74 (323.6)

6.00 (152.4)

22.00 (558.8)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

12.06 (306.3)

95

15CLPT-GDM-B

17.46 (443.5)

6.00 (152.4)

26.63 (676.4)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

12.06 (306.3)

95

15CLPT-PDM-B

17.46 (443.5)

6.00 (152.4)

26.63 (676.4)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

12.06 (306.3)

95

15CLPY-HPDM-A

12.74 (323.6)

6.00 (152.4)

22.00 (558.8)

0.75 (19.0)

1.75 (44.4)

8.50 (215.9)

13.56 (344.4)

110

15CLPT-HPDM-B

17.46 (443.5)

6.00 (152.4)

26.63 (676.4)

0.75 (19.0)

1.75 (44.4)

8.50 (215.9)

13.56 (344.4)

110

25CLPT-PNM-A

19.12 (485.6)

7.00 (177.8)

26.63 (676.4)

0.75 (19.0)

1.75 (44.4)

12.00 (304.8)

17.06 (433.3)

150

V14-T3-48

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

3
3

3
3
3
3
3

www.comoso.com

3.5

Current Limiting Fuses
CLPT and NCLPT Type Fuses

Approximate Dimensions in Inches (mm)

3

CLPT and NCLPT Type Non-Disconnect Mountings

3
G

3

F

D

3
E

3
3
3
3
3
A

3

C

3
3
3
3
3
3

E

3
D

B

3

Catalog
Number

Hole Centers
A

Hole Centers
B

Overall Length
C

Hole Inset
D

Hole Centers
E

Contact Height
F

Overall Height
G

BIL
Rating

5CLPT-GNM-A

9.37 (238.0)

6.00 (152.4)

18.63 (473.2)

0.75 (19.0)

1.75 (44.4)

4.50 (114.3)

6.94 (176.2)

60

5CLPT-PNM-A

9.37 (238.0)

6.00 (152.4)

18.63 (473.2)

0.75 (19.0)

1.75 (44.4)

4.50 (114.3)

6.94 (176.2)

60

8CLPT-GNM-A

9.37 (238.0)

6.00 (152.4)

18.63 (473.2)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

9.44 (239.8)

75

8CLPT-PNM-A

9.37 (238.0)

6.00 (152.4)

18.63 (473.2)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

9.44 (239.8)

75

8CLPT-GNM-B

12.75 (323.8)

6.00 (152.4)

22.00 (558.8)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

9.44 (239.8)

75

8CLPT-PNM-B

12.75 (323.8)

6.00 (152.4)

22.00 (558.8)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

9.44 (239.8)

75

15CLPT-GNM-A

12.74 (323.6)

6.00 (152.4)

22.00 (558.8)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

9.44 (239.8)

95

15CLPT-PNM-A

12.74 (323.6)

6.00 (152.4)

22.00 (558.8)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

9.44 (239.8)

95

15CLPT-HPNM-A

12.74 (323.6)

6.00 (152.4)

22.00 (558.8)

0.75 (19.0)

1.75 (44.4)

8.50 (215.9)

10.94 (277.9)

110

15CLPT-GNM-B

17.46 (443.5)

6.00 (152.4)

26.63 (676.4)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

9.44 (239.8)

95

15CLPT-PNM-B

17.46 (443.5)

6.00 (152.4)

26.63 (676.4)

0.75 (19.0)

1.75 (44.4)

7.00 (177.8)

9.44 (239.8)

95

15CLPT-HPNM-B

17.46 (443.5)

6.00 (152.4)

26.63 (676.4)

0.75 (19.0)

1.75 (44.4)

8.50 (215.9)

10.94 (277.9)

110

25CLPT-PNM-A

19.12 (485.6)

7.00 (177.8)

26.63 (676.4)

0.75 (19.0)

1.75 (44.4)

12.00 (304.8)

14.43 (367.0)

150

38CLPT-PNM-A

19.12 (485.6)

7.00 (177.8)

26.63 (676.4)

0.75 (19.0)

1.75 (44.4)

12.00 (304.8)

14.43 (367.0)

150

3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-49

3.6
3

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

Contents

Motor Start Fuses

Description

3

Page

ACLS, BCLS, CLS, HCLS and NCLS Type Fuses
UL Component Recognition . . . . . . . . . . . . . . .
Ratings and Selection . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3
3
3

V14-T3-51
V14-T3-51
V14-T3-51
V14-T3-59
V14-T3-63

3
3
3
3
3
3

ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

3

Product Description

CLS Features

Eaton’s CLS current limiting
fuses are used in conjunction
with medium voltage motor
starters to provide shortcircuit protection for
individual motor circuits.
Contactors in motor starting
equipment protect the
equipment from overcurrents due to starting,
stalling and plugging while
current limiting fuses provide
short-circuit protection only.

CLS type current limiting
fuses offer a number of
advantages over a number of
other designs. During the
selection process, consider
the following:

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Duty cycles of fuses used in
medium voltage motor
starters are characterized by
the frequent application of
high overloads such as motor
starting currents. Motor
starter fuses, therefore, must
be designed to withstand the
consequent frequent severe
heating and cooling cycles
without fatigue failures. CLS
type fuses have such a
construction. The element
designs used are not
sensitive to low currents, and
have “fatigue proof” features
to provide highly uniform
flexing of elements during
heating cycles.

●

●

●

Construction

Quiet Safe Operation:
CLS type current limiting
fuses are designed for
silent operation and
elimination of flame
discharges when the fuse
operates
Easy to Identify Operated
Fuse: CLS type current
limiting fuses are equipped
with an indicator that will
protrude indicating when a
fuse has operated
Space Economy: Because
the design of these fuses
has eliminated flame or
gas discharge, the need for
exhaust control devices,
vents and reinforcing is
eliminated

●

●

Complete Protection
Provided: CLS type
current limiting fuses
ensure positive
interruption of high fault
currents. The fuse limits
the magnitude of the
electromechanical stresses
in the protected apparatus.
They also limit the arc
voltage to considerably
less than three times the
nominal circuit voltage
Fatigue Proof: Controlled
“crimping” of the silver
elements during fuse
manufacture permits CLS
type current limiting fuses
to withstand severe duty
cycling without failure

The mounting possibilities for
CLS type current limiting
fuses are shown on Page
V14-T3-64, with disconnect
type being the predominant
approach.

3
V14-T3-50

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

CLS type current limiting
fuses are of basically
inorganic construction. The
only organic material used is
a high temperature glassresin outer casing and the
plastic indicator. The fuse
elements are pure silver and
are crimped at controlled
locations along the active
length to increase the
strength of the element, and
to uniformly distribute
mechanical expansion and
prevent fatigue failure due to
severe cycling duties.
Element design combines
maximum load carrying ability
with the most favorable short
circuit interruption
characteristics. These fuses
are filled with a high purity
silica sand with controlled
grain size.

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

UL® Component Recognition
Underwriters Laboratories
has witnessed testing on and
recognizes certain styles of
5CLS and 5ACLS fuses.
These fuses carry the
“reversed UR” designation.
CLS type current limiting
motor start fuses
manufactured prior to 1975
were not identified by an “R”
designation. However, these
fuses can be used with or
replaced by newer fuses with
“R” designations as indicated
below.

Ratings and Selection
When a decision has been
made to use current limiting
fuses, the minimum amount
of information required to
make the proper selection is:
●
●
●
●

Voltage rating
Current rating
Interrupting rating
Mounting method
●
Non-disconnect
mounting
●
Disconnect mounting
●
Clip-lock mounting
●
Direct bolt-in mounting
●
Live parts only
●
No required mounting

Refer to Pages V14-T3-52 to
V14-T3-62 for assistance in
selecting the correct fuse
catalog number.

3.6

Catalog Number Selection

3

CLS Fuse Units

3

These types of fuses are
used in conjunction with high
voltage motor starters to
provide short-circuit
protection for individual
motors. There are specific
rules governing the selection
of the required fuse
continuous rating.

15 CLS 200E
Maximum kV
2 = 2.75 kV
4 = 4.3 kV
5 = 5.5 kV
8 = 8.3 kV
15 = 15.5 kV

Type
ACLS
BCLS
CLS
HCLS

3
3

Continuos
Amperes
25A, 2R–44R

3
3
3

The current limiting fuse
application notes earlier in
this publication offer
additional information about
this type of application.

3
3
3

When selecting the
appropriate fuse for a new
installation, keep in mind that
one fuse unit and one
compatible mounting is
required for each phase.

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-51

3.6
3

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

CLS Type Current Limiting Fuses

3

Max.
Design Current
Voltage Rating “R”
Catalog
(kV)
(A)
Designation Number

Interrupting
Clip
Barrel
Rating rms Diameter Center
Number (kA Sym.)
(Inches) (Inches)

3

2.54

Length
(Inches)

Approx. Catalog Number
Shipping
End
Weight Live
Fittings 
(Lbs)
Parts 

Performance Curves
Minimum
Total
Melting
Clearing
Time
Time

25

—

2CLS-25

1

50

3

7

10.8

7

3

70

2R

2CLS-2R

1

50

3

7

10.8

7

100

3R

2CLS-3R

1

50

3

7

10.8

7

3

130

4R

2CLS-4R

1

50

3

7

10.8

7

150

5R

2CLS-5R

1

50

3

7

10.8

7

170

6R

2CLS-6R

1

50

3

7

10.8

7

200

9R

2CLS-9R

1

50

3

7

10.8

7

230

12R

2CLS-12R

1

50

3

7

10.8

7

3

390

18R

2CLS-18R

2

50

3

7

10.8

16

450

24R

2CLS-24R

2

50

3

7

10.8

16

3

25

—

2ACLS-25

1

50

3

—

10.8

7

70

2R

2ACLS-2R

1

50

3

—

10.8

7

100

3R

2ACLS-3R

1

50

3

—

10.8

7

130

4R

2ACLS-4R

1

50

3

—

10.8

7

150

5R

2ACLS-5R

1

50

3

—

10.8

7

3

170

6R

2ACLS-6R

1

50

3

—

10.8

7

200

9R

2ACLS-9R

1

50

3

—

10.8

7

3

230

12R

2ACLS-12R 1

50

3

—

10.8

7

390

18R

2ACLS-18R 2

50

3

—

10.8

16

450

24R

2ACLS-24R 2

50

3

—

10.8

16

3

25

—

2BCLS-25

1

50

3

—

—

8

70

2R

2BCLS-2R

1

50

3

—

—

8

3

100

3R

2BCLS-3R

1

50

3

—

—

8

130

4R

2BCLS-4R

1

50

3

—

—

8

150

5R

2BCLS-5R

1

50

3

—

—

8

170

6R

2BCLS-6R

1

50

3

—

—

8

200

9R

2BCLS-9R

1

50

3

—

—

8

3
3

3
3

3

3
3

230

12R

2BCLS-12R 1

50

3

—

—

8

390

18R

2BCLS-18R 2

50

3

—

—

17

450

24R

2BCLS-24R 2

50

3

—

—

17

25

—

2HCLS-25

1

50

3

—

10.8

7

70

2R

2HCLS-2R

1

50

3

—

10.8

7

100

3R

2HCLS-3R

1

50

3

—

10.8

7

130

4R

2HCLS-4R

1

50

3

—

10.8

7

3

150

5R

2HCLS-5R

1

50

3

—

10.8

7

170

6R

2HCLS-6R

1

50

3

—

10.8

7

3

200

9R

2HCLS-9R

1

50

3

—

10.8

7

230

12R

2HCLS-12R 1

50

3

—

10.8

7

390

18R

2HCLS-18R 2

50

3

—

10.8

16

450

24R

2HCLS-24R 2

50

3

—

10.8

16

3
3
3
3

3
3
3

Notes
 Includes end fittings.
 Disconnect only.

3
3
3
V14-T3-52

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Peak LetThrough
Current

CLE-NL-D
CLE-DL-D

—
CLE-DF-D

TC66664702 TC66664704 TC66700202

CLE-NL-E
CLE-DL-E

—
CLE-DF-E

TC66664702 TC66664704 TC66700202

—

TC66664702 TC66664704 TC66700202

—

TC66664702 TC66664704 TC66700202

—

TC66664702 TC66664704 TC66700202

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

3.6

CLS Type Current Limiting Fuses, continued
Max.
Design Current
Voltage Rating “R”
Catalog
(kV)
(A)
Designation Number

Interrupting
Clip
Barrel
Rating rms Diameter Center
Number (kA Sym.)
(Inches) (Inches)

5.5

Length
(Inches)

Performance Curves
Minimum
Total
Melting
Clearing
Time
Time

TC66690602 TC66690702 TC66700203

30

—

5CLS-30

1

50

3

12

15.9

8

70

2R

5CLS-2R

1

50

3

12

15.9

8

100

3R

5CLS-3R

1

50

3

12

15.9

8

130

4R

5CLS-4R

1

50

3

12

15.9

8

150

5R

5CLS-5R

1

50

3

12

15.9

8

170

6R

5CLS-6R

1

50

3

12

15.9

8

200

9R

5CLS-9R

1

50

3

12

15.9

8

230

12R

5CLS-12R

1

50

3

12

15.9

8

390

18R

5CLS-18R

2

50

3

12

15.9

17

450

24R

5CLS-24R

2

50

3

12

15.9

17

30

—

5ACLS-30

1

50

3

—

15.9

8

70

2R

5ACLS-2R

1

50

3

—

15.9

8

100

3R

5ACLS-3R

1

50

3

—

15.9

8

130

4R

5ACLS-4R

1

50

3

—

15.9

8

150

5R

5ACLS-5R

1

50

3

—

15.9

8

170

6R

5ACLS-6R

1

50

3

—

15.9

8

200

9R

5ACLS-9R

1

50

3

—

15.9

8

230

12R

5ACLS-12R 1

50

3

—

15.9

8

390

18R

5ACLS-18R 2

50

3

—

15.9

17

450

24R

5ACLS-24R 2

50

3

—

15.9

17

4.3

480

26R

4ACLS-26R 2

50

3

—

15.9

17

5.08

30

—

5BCLS-30

1

50

3

—

—

8

70

2R

5BCLS-2R

1

50

3

—

—

8

100

3R

5BCLS-3R

1

50

3

—

—

8

130

4R

5BCLS-4R

1

50

3

—

—

8

150

5R

5BCLS-5R

1

50

3

—

—

8

170

6R

5BCLS-6R

1

50

3

—

—

8

200

9R

5BCLS-9R

1

50

3

—

—

8

230

12R

5BCLS-12R 1

50

3

—

—

8

390

18R

5BCLS-18R 2

50

3

—

—

17

450

24R

5BCLS-24R 2

50

3

—

—

17

5.08

3

Approx. Catalog Number
Shipping
End
Weight Live
Fittings 
(Lbs)
Parts 

4.3

480

26R

4BCLS-26R 2

50

3

—

—

17

5.08

30

—

5HCLS-30

1

50

3

—

15.9

8

70

2R

5HCLS-2R

1

50

3

—

15.9

8

100

3R

5HCLS-3R

1

50

3

—

15.9

8

130

4R

5HCLS-4R

1

50

3

—

15.9

8

150

5R

5HCLS-5R

1

50

3

—

15.9

8

170

6R

5HCLS-6R

1

50

3

—

15.9

8

200

9R

5HCLS-9R

1

50

3

—

15.9

8

230

12R

5HCLS-12R 1

50

3

—

15.9

8

390

18R

5HCLS-18R 2

50

3

—

15.9

17

450

24R

5HCLS-24R 2

50

3

—

15.9

17

CLE-NL-D
CLE-DL-D

—
CLE-DF-D

Peak LetThrough
Current

3
3
3
3
3
3

CLE-NL-E
CLE-DL-E
—

—
CLE-DF-E

TC66690602 TC66690702 TC66700203

3

TC66690602 TC66690702 TC66700203

3
3
3
3
3
3

—

TC66690602 TC66690702 TC66700203

3
3
3
3
3
3
3

—

TC66690602 TC66690702 TC66700203

3
3
3
3
3
3

Notes
 Includes end fittings.
 Disconnect only.

3
3
3
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-53

3.6
3

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

CLS Type Current Limiting Fuses, continued

3

Max.
Design Current
Voltage Rating “R”
Catalog
(kV)
(A)
Designation Number

3

5.08

Interrupting
Clip
Barrel
Rating rms Diameter Center
Number (kA Sym.)
(Inches) (Inches)

Performance Curves

Length
(Inches)

Approx. Catalog Number
Shipping
Weight Live
End
(Lbs)
Parts 
Fittings 

TC66690602 TC66690702 TC66700203

70

2R

5CLS70-2R 2

50

3

—

—

20

3

100

3R

5CLS70-3R 2

50

3

—

—

20

130

4R

5CLS70-4R 2

50

3

—

—

20

3

150

5R

5CLS70-5R 2

50

3

—

—

20

170

6R

5CLS70-6R 2

50

3

—

—

20

200

9R

5CLS70-9R 2

50

3

—

—

20

230

12R

5CLS70-12R 2

50

4

—

—

40

390

18R

5CLS70-18R 2

50

4

—

—

40

3

450

24R

5CLS70-24R 2

50

4

—

—

40

600

32R

5CLS70-32R 2

50

4

—

—

40

3

650

36R

5CLS70-36R 2

50

4

—

—

40

700

44R

5CLS70-44R 2

50

4

—

—

40

70

2R

5LCLS-2R

1

50

3

14

17.9

11

100

3R

5LCLS-3R

1

50

3

14

17.9

11

130

4R

5LCLS-4R

1

50

3

14

17.9

11

3

150

5R

5LCLS-5R

1

50

3

14

17.9

11

170

6R

5LCLS-6R

1

50

3

14

17.9

11

3

200

9R

5LCLS-9R

1

50

3

14

17.9

11

230

12R

5LCLS-12R 1

50

3

14

17.9

11

390

18R

5LCLS-18R 2

50

3

14

17.9

22

450

24R

5LCLS-24R 2

50

3

14

17.9

22

70

2R

8CLS-2R

1

50

3

12

15.9

7

100

3R

8CLS-3R

1

50

3

12

15.9

7

130

4R

8CLS-4R

1

50

3

12

15.9

7

150

5R

8CLS-5R

1

50

3

12

15.9

7

170

6R

8CLS-6R

1

50

3

12

15.9

7

200

9R

7CLS-9R

1

50

3

12

15.9

7

230

12R

7CLS-12R

1

50

3

12

15.9

7

390

18R

7CLS-18R

2

50

3

12

15.9

16

450

24R

7CLS-24R

2

50

3

12

15.9

16

70

2R

7BCLS-2R

1

50

3

—

—

—

100

3R

7BCLS-3R

1

50

3

—

—

—

130

4R

7BCLS-4R

1

50

3

—

—

—

150

5R

7BCLS-5R

1

50

3

—

—

—

3

170

6R

7BCLS-6R

1

50

3

—

—

—

200

9R

7BCLS-9R

1

50

3

—

—

—

3

230

12R

7BCLS-12R 1

50

3

—

—

—

390

18R

7BCLS-18R 2

50

3

—

—

—

450

24R

7BCLS-24R 2

50

3

—

—

—

3
3

3

5.5

3

3
3

8.3

3
3
3
3

7.2

3
8.3

3
3

3
3
3

7.2

Notes
 Includes end fittings.
 Disconnect only.

3
3
3
V14-T3-54

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

—

Minimum
Melting
Time

Total
Clearing
Time

Peak LetThrough
Current

CLE-NL-D
CLE-DL-D
CLE-DF-D

—
CLE-DF-D
CLE-DF-D

TC51285302 TC51285402 TC66700204

CLE-NL-D
CLE-DL-D

—
CLE-DF-D

TC66700602 TC66700702 TC66700205

CLE-NL-E
CLE-DL-E

—
CLE-DF-E

TC66700602 TC66700702 TC66700205

—

TC66700602 TC66700702 TC66740205

3.6

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

CLS Type Current Limiting Fuses, continued
Max.
Design Current
Voltage Rating “R”
Catalog
(kV)
(A)
Designation Number

Interrupting
Clip
Barrel
Rating rms Diameter Center
Number (kA Sym.)
(Inches) (Inches)

8.3

7.2

8.3

3

Performance Curves

Length
(Inches)

Approx. Catalog Number
Shipping
Weight Live
End
(Lbs)
Parts 
Fittings 

TC66700602 TC66700702 TC66740205

70

2R

8ACLS-2R

1

50

3

—

15.9

8

100

3R

8ACLS-3R

1

50

3

—

15.9

8

130

4R

8ACLS-4R

1

50

3

—

15.9

8

150

5R

8ACLS-5R

1

50

3

—

15.9

8

170

6R

8ACLS-6R

1

50

3

—

15.9

8

200

9R

7ACLS-9R

1

50

3

—

15.9

8

230

12R

7ACLS-12R 1

50

3

—

15.9

8

390

18R

7ACLS-18R 2

50

3

—

15.9

17

450

24R

7ACLS-24R 2

50

3

—

15.9

17

450

24R

7CLS70-24R 2

50

3

—

—

20

650

36R

7CLS70-36R 3

50

3

—

—

30

700

44R

7CLS70-44R 2

50

4

—

—

40

15

—

8CLS-15

1

50

3

14

17.9

11

30

—

8CLS-30

1

50

3

14

17.9

11

60

—

8CLS-60

1

50

3

14

17.9

11

70

—

8CLS-70

1

50

3

14

17.9

11

90

—

8CLS-90

1

50

3

14

17.9

11

110

—

8CLS-110

1

50

3

14

17.9

11

125

—

8CLS-125

1

50

3

14

17.9

11

150

—

8CLS-150

2

50

3

14

17.9

22

200

—

8CLS-200

2

50

3

14

17.9

22

225

—

8CLS-225

2

50

3

14

17.9

22

—

Minimum
Melting
Time

Total
Clearing
Time

Peak LetThrough
Current

3
3
3
3
3
3
3
3

CLE-NL-D
CLE-DL-D

—
CLS-DF-D

TC66664202 TC66664302 TC66679802

3
3
3
3

CLE-NL-E
CLE-DL-E

—
CLE-DF-E

TC66664202 TC66664302 TC66679802

3
3
3

Notes
 Includes end fittings.
 Disconnect only.

3
3
3
3
3
3
3
3
3
3
3
3
3
3
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-55

3.6
3

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

CLS Type Current Limiting Fuses—Mounting
Mounting (Includes Live Parts, End Fittings)

3

Maximum
Design
Voltage (kV)

3

2.54

Current
Rating
(Amperes)

“R”
Designation

Catalog
Number

25

—

2CLS-25

70

2R

2CLS-2R

100

3R

2CLS-3R

130

4R

2CLS-4R

150

5R

2CLS-5R

3

170

6R

2CLS-6R

200

9R

2CLS-9R

3

230

12R

2CLS-12R

390

18R

2CLS-18R

3

450

24R

2CLS-24R

25

—

2ACLS-25

3

70

2R

2ACLS-2R

100

3R

2ACLS-3R

130

4R

2ACLS-4R

3

150

5R

2ACLS-5R

170

6R

2ACLS-6R

3

200

9R

2ACLS-9R

230

12R

2ACLS-12R

3

390

18R

2ACLS-18R

450

24R

2ACLS-24R

25

—

2BCLS-25

70

2R

2BCLS-2R

100

3R

2BCLS-3R

3

130

4R

2BCLS-4R

150

5R

2BCLS-5R

3

170

6R

2BCLS-6R

200

9R

2BCLS-9R

3

230

12R

2BCLS-12R

390

18R

2BCLS-18R

450

24R

2BCLS-24R

25

—

2HCLS-25

70

2R

2HCLS-2R

3

100

3R

2HCLS-3R

130

4R

2HCLS-4R

3

150

5R

2HCLS-5R

170

6R

2HCLS-6R

3

200

9R

2HCLS-9R

230

12R

2HCLS-12R

390

18R

2HCLS-18R

450

24R

2HCLS-24R

30

—

5CLS-30

3

70

2R

5CLS-2R

100

3R

5CLS-3R

3

130

4R

5CLS-4R

150

5R

5CLS-5R

3

170

6R

5CLS-6R

200

9R

5CLS-9R

230

12R

5CLS-12R

3
3

3

3
3

3
3

3
3

5.5

3

Type

Voltage
(BIL) kV

Catalog Number
Porcelain
Glass-Polyester

Non-disconnect
Disconnect

60
60

2CLE-PNM-D
2CLE-PDM-D

2CLE-GNM-D
2CLE-GDM-E

Non-disconnect
Disconnect

60
60

2CLE-PNM-E
2CLE-PDME

2CLE-GNM-E
2CLE-GDM-E

For use with Ampgard 400A motor starters

Bolt-in

Hermetically sealed fuses for use with Ampgard 400A motor starters

Non-disconnect
Disconnect

60
60

5HLE-PNM-D
5HLE-PDM-D

3
V14-T3-56

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

5HLE-GNM-D
5HLE-GDM-E

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

3.6

CLS Type Current Limiting Fuses—Mounting, continued

3

Mounting (Includes Live Parts, End Fittings)
Maximum
Design
Voltage (kV)
5.5
5.08

Current
Rating
(Amperes)

“R”
Designation

Catalog
Number

390

18R

5CLS-18R

450

24R

5CLS-24R

30

—

5ACLS-30

70

2R

5ACLS-2R

100

3R

5ACLS-3R

130

4R

5ACLS-4R

150

5R

5ACLS-5R

170

6R

5ACLS-6R

200

9R

5ACLS-9R

230

12R

5ACLS-12R

390

18R

5ACLS-18R

450

24R

5ACLS-24R

4.3

480

26R

4ACLS-26R

5.08

30

—

5BCLS-30

70

2R

5BCLS-2R

100

3R

5BCLS-3R

130

4R

5BCLS-4R

150

5R

5BCLS-5R

170

6R

5BCLS-6R

200

9R

5BCLS-9R

230

12R

5BCLS-12R

390

18R

5BCLS-18R

450

24R

5BCLS-24R

4.3

480

26R

4BCLS-26R

5.08

30

—

5HCLS-30

70

2R

5HCLS-2R

100

3R

5HCLS-3R

130

4R

5HCLS-4R

150

5R

5HCLS-5R

170

6R

5HCLS-6R

200

9R

5HCLS-9R

230

12R

5HCLS-12R

390

18R

5HCLS-18R

450

24R

5HCLS-24R

70

2R

5CLS70-2R

100

3R

5CLS70-3R

130

4R

5CLS70-4R

150

5R

5CLS70-5R

170

6R

5CLS70-6R

200

9R

5CLS70-9R

230

12R

5CLS70-12R

390

18R

5CLS70-18R

450

24R

5CLS70-24R

600

32R

5CLS70-32R

650

36R

5CLS70-36R

700

44R

5CLS70-44R

Type

Voltage
(BIL) kV

Catalog Number
Porcelain
Glass-Polyester

3

Non-disconnect
Disconnect

60
60

5HLE-PNM-E
5HLE-PDME

3

5HLE-GNM-E
5HLE-GDM-E

3

For use with Ampgard 400A motor starters

3
3
3
3
3
3

Bolt-in

3
3
3
3
3
3

Hermetically sealed for use with Ampgard 400A motor starters

3
3
3
3
3
For use with Ampgard 800A motor starters

3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-57

3.6
3

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

CLS Type Current Limiting Fuses—Mounting, continued
Mounting (Includes Live Parts, End Fittings)

3

Maximum
Design
Voltage (kV)

3

5.5

Current
Rating
(Amperes)

“R”
Designation

Catalog
Number

70

2R

5LCLS-2R

100

3R

5LCLS-3R

130

4R

5LCLS-4R

150

5R

5LCLS-5R

170

6R

5LCLS-6R

3

200

9R

5LCLS-9R

230

12R

5LCLS-12R

3

390

18R

5LCLS-18R

450

24R

5LCLS-24R

70

2R

8CLS-2R

100

3R

8CLS-3R

130

4R

8CLS-4R

150

5R

8CLS-5R

170

6R

8CLS-6R

200

9R

7CLS-9R

230

12R

7CLS-12R

390

18R

7CLS-18R

450

24R

7CLS-24R

70

2R

7BCLS-2R

100

3R

7BCLS-3R

130

4R

7BCLS-4R

150

5R

7BCLS-5R

170

6R

7BCLS-6R

200

9R

7BCLS-9R

230

12R

7BCLS-12R

390

18R

7BCLS-18R

450

24R

7BCLS-24R

70

2R

8ACLS-2R

100

3R

8ACLS-3R

130

4R

8ACLS-4R

150

5R

8ACLS-5R

170

6R

8ACLS-6R

200

9R

7ACLS-9R

230

12R

7ACLS-12R

3

390

18R

7ACLS-18R

450

24R

7ACLS-24R

3

450

24R

7CLS70-24R

650

36R

7CLS70-36R

3
3

3

8.3

3
3
3
3

7.2

3

8.3

3
3
3
3

7.2

3

8.3

3
3
3

7.2

3

700

44R

7CLS70-44R

15

—

8CLS-15

30

—

8CLS-30

3

60

—

8CLS-60

70

—

8CLS-70

3

90

—

8CLS-90

110

—

8CLS-110

3

125

—

8CLS-125

150

—

8CLS-150

200

—

8CLS-200

225

—

8CLS-225

3

8.3

3
3
V14-T3-58

Type

Voltage
(BIL) kV

Catalog Number
Porcelain
Glass-Polyester

Non-disconnect
Disconnect
Disconnect

60
60
75

5CLE-PNM-D
5CLE-PDM-D
8CLE-PDM-D

5CLE-GNM-D
5CLE-GDM-D
8CLE-GDM-D

Non-disconnect
Disconnect

75
75

8HLE-PNM-D
8HLE-PDM-D

8HLE-GNM-D
8HLE-GDM-D

Non-disconnect
Disconnect

75
75

8HLE-PDM-E
8HLE-PDM-E

8HLE-GNM-E
8HLE-GDM-E

Bolt-in

For use with Ampgard 400A motor starters

For use with Ampgard 800A motor starters

Non-disconnect
Disconnect

75
75

8CLE-PNM-D
8CLE-PDM-D

8CLE-GNM-D
8CLE-GDM-D

Non-disconnect
Disconnect

75
75

8CLE-PNM-E
8CLE-PDM-E

8CLE-GNM-E
8CLE-GDM-E

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.6

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

Product Selection

3

CLS Type

3

CLS Type Current Limiting Fuses
Clip
Performance Curves
Length
Maximum Current
Interrupting Diameter Center
Approximate
Peak
Design
Rating
“R”
Barrel Rating rms
Shipping
Minimum
Total
Let-Through Catalog
Voltage (kV) (Amperes) Designation Number (kA Sym.)
Approximate Dimensions in Inches (mm) Weight Lbs (kg) Melting Time Clearing Time Current
Number
2.54

25

—

1

50

3.00 (76.2) 7.00 (177.8)

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2CLS-25

70

2R

1

50

3.00 (76.2) 7.00 (177.8)

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2CLS-2R

100

3R

1

50

3.00 (76.2) 7.00 (177.8)

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2CLS-3R

130

4R

1

50

3.00 (76.2) 7.00 (177.8)

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2CLS-4R

150

5R

1

50

3.00 (76.2) 7.00 (177.8)

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2CLS-5R

170

6R

1

50

3.00 (76.2) 7.00 (177.8)

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2CLS-6R

200

9R

1

50

3.00 (76.2) 7.00 (177.8)

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2CLS-9R

230

12R

1

50

3.00 (76.2) 7.00 (177.8)

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2CLS-12R

390

18R

2

50

3.00 (76.2) 7.00 (177.8)

10.80 (274.3) 16 (7.26)

TC66664702

TC66664704

TC66700202

2CLS-18R

450

24R

2

50

3.00 (76.2) 7.00 (177.8)

10.80 (274.3) 16 (7.26)

TC66664702

TC66664704

TC66700202

2CLS-24R

25

—

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2ACLS-25

70

2R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2ACLS-2R

100

3R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2ACLS-3R

130

4R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2ACLS-4R

150

5R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2ACLS-5R

170

6R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2ACLS-6R

200

9R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2ACLS-9R

230

12R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2ACLS-12R

390

18R

2

50

3.00 (76.2) Not applicable

10.80 (274.3) 16 (7.26)

TC66664702

TC66664704

TC66700202

2ACLS-18R

450

24R

2

50

3.00 (76.2) Not applicable

10.80 (274.3) 16 (7.26)

TC66664702

TC66664704

TC66700202

2ACLS-24R

25

—

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 8 (3.63)

TC66664702

TC66664704

TC66700202

2BCLS-25

70

2R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 8 (3.63)

TC66664702

TC66664704

TC66700202

2BCLS-2R

100

3R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 8 (3.63)

TC66664702

TC66664704

TC66700202

2BCLS-3R

130

4R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 8 (3.63)

TC66664702

TC66664704

TC66700202

2BCLS-4R

150

5R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 8 (3.63)

TC66664702

TC66664704

TC66700202

2BCLS-5R

170

6R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 8 (3.63)

TC66664702

TC66664704

TC66700202

2BCLS-6R

200

9R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 8 (3.63)

TC66664702

TC66664704

TC66700202

2BCLS-9R

230

12R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 8 (3.63)

TC66664702

TC66664704

TC66700202

2BCLS-12R

390

18R

2

50

3.00 (76.2) Not applicable

10.80 (274.3) 17 (7.72)

TC66664702

TC66664704

TC66700202

2BCLS-18R

450

24R

2

50

3.00 (76.2) Not applicable

10.80 (274.3) 17 (7.72)

TC66664702

TC66664704

TC66700202

2BCLS-24R

25

—

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2HCLS-25

70

2R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2HCLS-2R

100

3R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2HCLS-3R

130

4R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2HCLS-4R

150

5R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2HCLS-5R

170

6R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2HCLS-6R

200

9R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2HCLS-9R

230

12R

1

50

3.00 (76.2) Not applicable

10.80 (274.3) 7 (3.18)

TC66664702

TC66664704

TC66700202

2HCLS-12R

390

18R

2

50

3.00 (76.2) Not applicable

10.80 (274.3) 16 (7.26)

TC66664702

TC66664704

TC66700202

2HCLS-18R

450

24R

2

50

3.00 (76.2) Not applicable

10.80 (274.3) 16 (7.26)

TC66664702

TC66664704

TC66700202

2HCLS-24R

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-59

3.6
3

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

CLS Type Current Limiting Fuses, continued

3

Clip
Performance Curves
Length
Maximum Current
Interrupting Diameter Center
Approximate
Peak
Design
Rating
“R”
Barrel Rating rms
Shipping
Minimum
Total
Let-Through Catalog
Voltage (kV) (Amperes) Designation Number (kA Sym.)
Approximate Dimensions in Inches (mm) Weight Lbs (kg) Melting Time Clearing Time Current
Number

3

5.08

30

—

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5CLS-30

3

70

2R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5CLS-2R

100

3R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5CLS-3R

3

130

4R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5CLS-4R

150

5R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5CLS-5R

170

6R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5CLS-6R

200

9R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5CLS-9R

230

12R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5CLS-12R

390

18R

2

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 17 (7.72)

TC66690602

TC66690702

TC66700203

5CLS-18R

450

24R

2

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 17 (7.72)

TC66690602

TC66690702

TC66700203

5CLS-24R

30

—

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5ACLS-30

3
3
3
3

5.08

70

2R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5ACLS-2R

100

3R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5ACLS-3R

130

4R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5ACLS-4R

150

5R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5ACLS-5R

3

170

6R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5ACLS-6R

200

9R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5ACLS-9R

3

230

12R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5ACLS-12R

390

18R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 17 (7.72)

TC66690602

TC66690702

TC66700203

5ACLS-18R

3
3

3

450

24R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 17 (7.72)

TC66690602

TC66690702

TC66700203

5ACLS-24R

4.3

480

26R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 17 (7.72)

TC66690602

TC66690702

TC66700203

4ACLS-26R

5.08

30

—

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5BCLS-30

70

2R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5BCLS-2R

100

3R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5BCLS-3R

130

4R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5BCLS-4R

150

5R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5BCLS-5R

170

6R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5BCLS-6R

3

200

9R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5BCLS-9R

230

12R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5BCLS-12R

3

390

18R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 17 (7.72)

TC66690602

TC66690702

TC66700203

5BCLS-18R

450

24R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 17 (7.72)

TC66690602

TC66690702

TC66700203

5BCLS-24R

4.3

480

26R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 17 (7.72)

TC66690602

TC66690702

TC66700203

4BCLS-26R

5.08

30

—

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5HCLS-30

70

2R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5HCLS-2R

3

100

3R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5HCLS-3R

130

4R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5HCLS-4R

3

150

5R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5HCLS-5R

170

6R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5HCLS-6R

200

9R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5HCLS-9R

3

230

12R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66690602

TC66690702

TC66700203

5HCLS-12R

390

18R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 17 (7.72)

TC66690602

TC66690702

TC66700203

5HCLS-18R

3

450

24R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 17 (7.72)

TC66690602

TC66690702

TC66700203

5HCLS-24R

3
3
3
3

3
3

3

3
3
3
V14-T3-60

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.6

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

CLS Type Current Limiting Fuses, continued
Clip
Performance Curves
Length
Maximum Current
Interrupting Diameter Center
Approximate
Peak
Design
Rating
“R”
Barrel Rating rms
Shipping
Minimum
Total
Let-Through Catalog
Voltage (kV) (Amperes) Designation Number (kA Sym.)
Approximate Dimensions in Inches (mm) Weight Lbs (kg) Melting Time Clearing Time Current
Number
5.08

5.5

8.3

7.2

8.3

7.2

8.3

70

2R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 20 (9.08)

TC66690602

TC66690702

TC66700203

5CLS70-2R

100

3R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 20 (9.08)

TC66690602

TC66690702

TC66700203

5CLS70-3R

130

4R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 20 (9.08)

TC66690602

TC66690702

TC66700203

5CLS70-4R

150

5R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 20 (9.08)

TC66690602

TC66690702

TC66700203

5CLS70-5R

170

6R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 20 (9.08)

TC66690602

TC66690702

TC66700203

5CLS70-6R

200

9R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 20 (9.08)

TC66690602

TC66690702

TC66700203

5CLS70-9R

230

12R

2

50

4.00 (101.6) Not applicable

15.90 (403.9) 40 (18.16)

TC66690602

TC66690702

TC66700203

5CLS70-12R

390

18R

2

50

4.00 (101.6) Not applicable

15.90 (403.9) 40 (18.16)

TC66690602

TC66690702

TC66700203

5CLS70-18R

450

24R

2

50

4.00 (101.6) Not applicable

15.90 (403.9) 40 (18.16)

TC66690602

TC66690702

TC66700203

5CLS70-24R

600

32R

2

50

4.00 (101.6) Not applicable

15.90 (403.9) 40 (18.16)

TC66690602

TC66690702

TC66700203

5CLS70-32R

650

36R

2

50

4.00 (101.6) Not applicable

15.90 (403.9) 40 (18.16)

TC66690602

TC66690702

TC66700203

5CLS70-36R

700

44R

2

50

4.00 (101.6) Not applicable

15.90 (403.9) 40 (18.16)

TC66690602

TC66690702

TC66700203

5CLS70-44R

70

2R

1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC51285302

TC51285402

TC66700204

5LCLS-2R

100

3R

1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC51285302

TC51285402

TC66700204

5LCLS-3R

130

4R

1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC51285302

TC51285402

TC66700204

5LCLS-4R

150

5R

1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC51285302

TC51285402

TC66700204

5LCLS-5R

170

6R

1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC51285302

TC51285402

TC66700204

5LCLS-6R

200

9R

1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC51285302

TC51285402

TC66700204

5LCLS-9R

230

12R

1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC51285302

TC51285402

TC66700204

5LCLS-12R

390

18R

2

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 22 (9.99)

TC51285302

TC51285402

TC66700204

5LCLS-18R

450

24R

2

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 22 (9.99)

TC51285302

TC51285402

TC66700204

5LCLS-24R

70

2R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66700205

8CLS-2R

100

3R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66700205

8CLS-3R

130

4R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66700205

8CLS-4R

150

5R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66700205

8CLS-5R

170

6R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66700205

8CLS-6R

200

9R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66700205

7CLS-9R

230

12R

1

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66700205

7CLS-12R

390

18R

2

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 16 (7.26)

TC66700602

TC66700702

TC66700205

7CLS-18R

450

24R

2

50

3.00 (76.2)

12.00 (304.8)

15.90 (403.9) 16 (7.26)

TC66700602

TC66700702

TC66700205

7CLS-24R

70

2R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66740205

7BCLS-2R

100

3R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66740205

7BCLS-3R

130

4R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66740205

7BCLS-4R

150

5R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66740205

7BCLS-5R

170

6R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66740205

7BCLS-6R

200

9R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66740205

7BCLS-9R

230

12R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 7 (3.18)

TC66700602

TC66700702

TC66740205

7BCLS-12R

390

18R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 16 (7.26)

TC66700602

TC66700702

TC66740205

7BCLS-18R

450

24R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 16 (7.26)

TC66700602

TC66700702

TC66740205

7BCLS-24R

70

2R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66700602

TC66700702

TC66740205

8ACLS-2R

100

3R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66700602

TC66700702

TC66740205

8ACLS-3R

130

4R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66700602

TC66700702

TC66740205

8ACLS-4R

150

5R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66700602

TC66700702

TC66740205

8ACLS-5R

170

6R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66700602

TC66700702

TC66740205

8ACLS-6R

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-61

3.6
3

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

CLS Type Current Limiting Fuses, continued

3

Clip
Performance Curves
Length
Maximum Current
Interrupting Diameter Center
Approximate
Peak
Design
Rating
“R”
Barrel Rating rms
Shipping
Minimum
Total
Let-Through Catalog
Voltage (kV) (Amperes) Designation Number (kA Sym.)
Approximate Dimensions in Inches (mm) Weight Lbs (kg) Melting Time Clearing Time Current
Number

3

7.2

200

9R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66700602

TC66700702

TC66740205

7ACLS-9R

3

230

12R

1

50

3.00 (76.2)

Not applicable

15.90 (403.9) 8 (3.63)

TC66700602

TC66700702

TC66740205

7ACLS-12R

390

18R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 17 (7.72)

TC66700602

TC66700702

TC66740205

7ACLS-18R

3

450

24R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 17 (7.72)

TC66700602

TC66700702

TC66740205

7ACLS-24R

450

24R

2

50

3.00 (76.2)

Not applicable

15.90 (403.9) 20 (9.08)

TC66700602

TC66700702

TC66740205

7CLS70-24R

650

36R

3

50

3.00 (76.2)

Not applicable

15.90 (403.9) 30 (13.62)

TC66700602

TC66700702

TC66740205

7CLS70-36R

700

44R

2

50

4.00 (101.6) Not applicable

15.90 (403.9) 40 (18.16)

TC66700602

TC66700702

TC66740205

7CLS70-44R

15

Not applicable 1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC66664202

TC66664302

TC66679802

8CLS-15

3

30

Not applicable 1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC66664202

TC66664302

TC66679802

8CLS-30

60

Not applicable 1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC66664202

TC66664302

TC66679802

8CLS-60

3

70

Not applicable 1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC66664202

TC66664302

TC66679802

8CLS-70

3
3

8.3

3
3
3

90

Not applicable 1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC66664202

TC66664302

TC66679802

8CLS-90

110

Not applicable 1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC66664202

TC66664302

TC66679802

8CLS-110

125

Not applicable 1

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 11 (4.99)

TC66664202

TC66664302

TC66679802

8CLS-125

150

Not applicable 2

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 22 (9.99)

TC66664202

TC66664302

TC66679802

8CLS-150

200

Not applicable 2

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 22 (9.99)

TC66664202

TC66664302

TC66679802

8CLS-200

225

Not applicable 2

50

3.00 (76.2)

14.00 (355.6)

17.90 (454.7) 22 (9.99)

TC66664202

TC66664302

TC66679802

8CLS-225

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
V14-T3-62

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.6

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

Dimensions
Approximate Dimensions in Inches (mm)

3

CLS Type Fuse

3
3
3

3.31
Ref.
(84.1)

3
10.81 (274.6) 0.06 for 2CLS
15.85 (402.6) 0.06 for 5, 7 and 8CLS

3
3

3.00 Dia. Ref.
(76.2)

3

10.81 (274.6) 0.06 for 2CLS
15.85 (402.6) 0.06 for 5, 7 and 8CLS

3
3

5BCLS and 7BCLS Type Fuses

3

0.455 (11.6) Dia. x 0.91 Slot (4)
2.12
(53.8)

3.00
(76.2)
Ref.

2.12
(53.8)

3.31
(84.1)

1.53
(38.9)

17.88
(454.2)

17.88 0.06
(454.2)

19.25
(488.9)

19.25
Ref.
(488.9)

3
3
3

3.00
(76.2)
Ref.

3
3

2BCLS Type Fuse

3

0.455 (11.6) Dia. x 0.91 Slot (4)

3
2.12
(53.8)

3.31
(84.1)

1.53
(38.9)

3.00
(76.2)
Ref.

2.12
(53.8)

17.88
(454.2)

17.88 0.06
(454.2)

19.25
(488.9)

19.25
Ref.
(488.9)

3
3

3.00
(76.2)
Ref.

3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-63

3.6
3
3
3

Current Limiting Fuses
ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

CLS Type Mountings and Hardware
Maximum
Design
Voltage (kV)

Ampere
Rating

2.54

25–230

3

390–450

3
3

5.5 (CLS)

390–480

3
3

30–230

5.5 (LCLS)

70–230

3

Porcelain Insulator
Catalog Number

Glass-Polyester Insulator
Catalog Number

Catalog Number

Catalog Number

Non-disconnect

60

2CLE-PNM-D

2CLE-GNM-D

CLE-NL-D

—

Disconnect

60

2CLE-PDM-D

2CLE-GDM-E

CLE-DL-D

CLE-DF-D

Non-disconnect

60

2CLE-PNM-E

2CLE-GNM-E

CLE-NL-E

—

Disconnect

60

2CLE-PDM-E

2CLE-GDM-E

CLE-DL-E

CLE-DF-E

Non-disconnect

60

5HLE-PNM-D

5HLE-GNM-D

CLE-NL-D

—

Disconnect

60

5HLE-PDM-D

5HLE-GDM-E

CLE-DL-D

CLE-DF-D
—

Non-disconnect

60

5HLE-PNM-E

5HLE-GNM-E

CLE-NL-E

Disconnect

60

5HLE-PDM-E

5HLE-GDM-E

CLE-DL-E

CLE-DF-E

Non-disconnect

60

5CLE-PNM-D

5CLE-GNM-D

CLE-NL-D

—
CLE-DF-D

5CLE-GDM-D

CLE-DL-D

8CLE-PDM-D

8CLE-GDM-D

CLE-DL-D

CLE-DF-D

60

5CLE-PNM-E

5CLE-GNM-E

CLE-NL-E

—

60

5CLE-PDM-E

5CLE-GDM-E

CLE-DL-E

CLE-DF-E

75

8CLE-PDM-E

8CLE-PDM-E

CLE-DL-E

CLE-DF-E
—

Non-disconnect

75

8HLE-PNM-D

8HLE-GNM-D

CLE-NL-D

Disconnect

75

8HLE-PDM-D

8HLE-GDM-D

CLE-DL-D

CLE-DF-D

7.2

390–450

Non-disconnect

75

8HLE-PDM-E

8HLE-GNM-E

CLE-NL-E

—

Disconnect

75

8HLE-PDM-E

8HLE-GDM-E

CLE-DL-E

CLE-DF-E

8.3

15–30

Non-disconnect

75

8CLE-PNM-D

8CLE-GNM-D

CLE-NL-D

—

3
3

5CLE-PDM-D

130–230

3

3

60
75

70–100

3
3

Non-disconnect
Disconnect

8.3

End Fittings
(Disconnect Only)

Voltage
BIL (kV)

Disconnect

3

Live Parts
(Including End Fittings)

Fuse Mounting
Type

3
390–450

Mounting
(Including Live Parts, End Fittings) 

60–125

Disconnect

75

8CLE-PDM-D

8CLE-GDM-D

CLE-DL-D

CLS-DF-D

150–225

Non-disconnect

75

8CLE-PNM-E

8CLE-GNM-E

CLE-NL-E

—

Disconnect

75

8CLE-PDM-E

8CLE-GDM-E

CLE-DL-E

CLE-DF-E

Note
 Disconnect only.

3
3
3
3
3
3
3
3
3
3
3
3
3
V14-T3-64

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current Limiting Fuses
CLT Type Fuses

3.7

Contents

CLT Fuse

Description

Page

CLT Type Fuses
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3
3

V14-T3-66
V14-T3-66

3
3
3
3
3
3
3
3
3

CLT Type Fuses

3

Applications

CLT Features

Eaton’s CLT fuses are
designed specifically to
provide fault protection on
high capacity indoor and
underground distribution
systems. These general
purpose current limiting
fuses meet or exceed C37
standards for this class of
distribution fuse. CLT fuses
may be used in conjunction
with EFD load break switches
that meet the full switching
requirements of underground
distribution systems using
pad-mounted transformers.
In addition, CLT fuses may be
applied in pad-mounted
transformer drawout wells or
in conjunction with LBOR oil
switches as a means of lowcost transformer protection.

CLT type current limiting
fuses offer a number of
desirable advantages.
Consider the following during
the selection process:

Fuse Ratings Available

●

Voltage (kV)

●

●

Amperes

2.75

5–150

5.5

8–60

8.3

5–45

14.4

30

15.5

4–18

●

Quiet Safe Operation:
CLT fuses are nonindicating and will clear
all currents from minimum
melting to maximum
interrupting rating without
any external disturbance or
expulsion of gas
Limits Fault Current LetThrough: The let-through
current for a high shortcircuit fault is limited to a
value far below the
available peak current
because the current is
forced to zero before the
end of the first half cycle
Arc-Voltage Protection:
CLT fuses control the arc
voltage that is produced
during current limitation to
less than three times the
normal operating voltage
rating
Maintains NonConductance After
Interruption: Specially
designed cores prevent
internal flash through
when rated voltage
remains across the fuse
after interruption

●

Low-Cost Transformer
Protection: The CLT fuse
can be used in EFD load
break switches and dry
well drawout holders

Construction and Operation
CLT fuses are constructed with
pure silver fuse elements, high
purity silica sand fill with
controlled grain size, a specially
designed core, and a glassepoxy outer casing.
During a high fault current, the
silver element(s) melts almost
instantly losing energy to the
surrounding sand. The energy
melts the sand forming a glasslike substance commonly
referred to as “fulgurite.” The
arc voltage rapidly increases to
about three times the fuse
voltage rating, forcing the
current to zero. The fault
current is interrupted in one-half
cycle or less without noise or
expulsion of gases.
Current limiting action occurs
only when the current is above
the threshold current for the
fuse, that is, the current is high
enough to melt the fuse
element(s) before the peak
value of current is reached in
the first half cycle.

Low level currents are cleared
by the melting of a tin solder
drop on the fuse element that
in turn causes the silver
element to melt. This is called
the M-effect. The silver
element then burns back until
there is sufficient internal gap
to interrupt the current.

Ratings and Selection
When a decision has been
made to use current limiting
fuses, the minimum amount
of information required to
make the proper selection is:
●
●
●
●

Voltage rating
Current rating
Interrupting rating
Mounting method

3
3
3
3
3
3
3
3
3

See the table on Page
V14-T3-66 for assistance
in selecting the correct fuse
catalog number.
These types of fuses are
designed specifically to
provide fault protection on
high capacity indoor and
underground distribution
systems.

3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-65

3.7

Current Limiting Fuses
CLT Type Fuses

3

Product Selection

3

CLT Type Current Limiting Fuses

3

Maximum
Design
Voltage (kV)

3

Performance Curves
Current Rating Catalog
(Amperes)
Number

2.75

Interrupting
Barrel Rating
Number rms (kA Sym.)

Approx.
Diameter
in (mm)

Length (Inches)

Approx.
Shipping
Weight (Lbs)

Minimum
Melting Time

Total Clearing
Time

Peak LetThrough
Current

TC59885801

TC66675901

TC62909001

TC59885803

TC66675903

TC62909002

TC59885805

TC66675905

TC62909003

TC59885701

TC66676001

TC63942701

TC59885701

TC66676001

TC63942701

5

2CLT-5

1

25

1.60 (40.6)

9.70 (246.4)

1.25

3

12

2CLT-12

1

25

1.60 (40.6)

9.70 (246.4)

1.25

18

2CLT-18

1

25

1.60 (40.6)

9.70 (246.4)

1.25

3

25

2CLT-25

1

25

1.60 (40.6)

9.70 (246.4)

1.25

30

2CLT-30

1

25

1.60 (40.6)

9.70 (246.4)

1.25

75

2CLT-75

1

25

1.60 (40.6)

9.70 (246.4)

1.25

90

2CLT-90

1

25

2.25 (57.1)

9.76 (248.0)

2.5

150

2CLT-150

1

25

2.25 (57.1)

9.76 (248.0)

2.5

8

5CLT-8

1

25

1.60 (40.6)

9.70 (246.4)

1.25

12

5CLT-12

1

25

1.60 (40.6)

9.70 (246.4)

1.25

18

5CLT-18

1

25

1.60 (40.6)

9.70 (246.4)

1.25

25

5CLT-25

1

25

1.60 (40.6)

9.70 (246.4)

1.25

30

5CLT-30

1

25

2.25 (57.1)

9.76 (248.0)

2.5

45

5CLT-45

1

25

2.25 (57.1)

9.76 (248.0)

2.5
2.5

3
3
3

5.5

3
3
3
3

8.3

3
3
3
3
15.5

3
3
3

14.4

60

5CLT-60

1

25

2.25 (57.1)

9.76 (248.0)

5

8CLT-5

1

25

1.60 (40.6)

9.70 (246.4)

1.25

8

8CLT-8

1

25

1.60 (40.6)

9.70 (246.4)

1.25

12

8CLT-12

1

25

1.60 (40.6)

9.70 (246.4)

1.25

18

8CLT-18

1

25

1.60 (40.6)

9.70 (246.4)

1.25

25

8CLT-25

1

25

1.60 (40.6)

9.70 (246.4)

1.25

30

8CLT-30

1

25

1.60 (40.6)

11.00 (279.4)

1.25

30

8CLT-30

1

25

2.25 (57.1)

9.76 (248.0)

2.5

45

8CLT-45

1

25

2.25 (57.1)

9.76 (248.0)

2.5

4

15CLT-4

1

25

2.25 (57.1)

9.76 (248.0)

2.5

5

15CLT-5

1

25

2.25 (57.1)

9.76 (248.0)

2.5

8

15CLT-8

1

25

2.25 (57.1)

9.76 (248.0)

2.5

12

15CLT-12

1

25

2.25 (57.1)

9.76 (248.0)

2.5

18

15CLT-18

1

25

2.25 (57.1)

9.76 (248.0)

2.5

30

15CLT-30

1

25

2.25 (57.1)

9.76 (248.0)

2.5

3
3
3

Dimensions
Approximate Dimensions in Inches (mm).
The drawing below specifies certain dimensions and references other dimensions.
Refer to the table above for the referenced dimensions of particular CLT type fuses.

3
3

CLT Type Fuse
0.250-20 (6.3-5.1) Threads (Both Ends)

3
3
3
3

0.62
(15.7)

Length

0.62
(15.7)

3
V14-T3-66

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current Limiting Fuses
CX, CXI and CXN Type Fuses

3.8

Contents

Eaton CX Fuses

Description
CX, CXI and CXN Type Fuses
CXN Construction . . . . . . . . . . . . . . . . . . . . . . .
CXN Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . .
CX Construction and Operation . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page

3
3

V14-T3-68
V14-T3-68
V14-T3-68
V14-T3-69
V14-T3-75

3
3
3
3
3
3
3
3
3

CX, CXI and CXN Type Fuses

3

Applications

CX, CXI and CXN Features

Eaton’s CX, CXI and CXN
general purpose current
limiting fuses are designed
specifically to provide
complete fault protection on
high capacity indoor and
underground distribution
systems. These fuses are
C-rated and exceed the
requirements of C37
standards for general
purpose distribution
current limiting fuses.

CX and CXN type current
limiting fuses offer a number
of desirable advantages.
Consider the following during
the selection process:

●

●

●
●

Pad-mounted and
submersible three-phase
and single-phase
transformers
Pad-mounted and
submersible switch and
fuse units
Station service protection
Primary switch and fuse
units on mine rectifiers

Note: CXI fuses are not suitable
for submersible applications.

CXN fuses are applied in:
●

●
●
●
●

Power transformer
protection
Power centers
Load interrupters
Feeder circuit protection
Mine rectifiers

●

●

●

Quiet Safe Operation: CX
and CXN fuses are nonindicating devices—CXI
fuses are indicating
devices. These fuses will
clear all currents from their
minimum melting current
to their maximum
interrupting rating without
any external disturbance or
expulsion of gas
Limits Fault Current LetThrough: The let-through
current for a high shortcircuit fault is limited to a
value far below the
available peak current
because the current is
forced to zero before the
end of the first half cycle
Arc-Voltage Protection:
CX and CXN fuses control
the arc voltage that is
produced during current
limitation to less than three
times the normal operating
voltage rating

●

●

●

Maintains NonConductance After
Interruption: An inorganic
core with spaced arc
guards prevent internal
flash through when rated
voltage remains across the
fuse after interruption
Fits Many Mountings: CX
and CXN fuses can be
used in disconnect and
non-disconnect mountings.
CX fuses can be used in
EFD load break switches
through 8.3 kV and dry well
drawout fuse holders
Interchangeable: CX and
CXI fuses are a direct
replacement for
competitive general
purpose distribution class
current limiting fuses

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-67

3.8
3
3
3
3
3
3
3
3
3

Current Limiting Fuses
CX, CXI and CXN Type Fuses

CXN Construction

CXN Ratings

CX Construction and Operation

CXN type fuses are
constructed with pure silver
fuse elements, high purity
silica sand filler with
controlled grain size, an
inorganic core with spaced
arc suppressors, and a glass
melamine or glass epoxy
outer casing.

The C-rating range is from
60C to 300C at 8.3 kV, with
some ratings including 300C
being achieved by paralleling
two (2) 150C single barrel
fuses.

CX and CXI type fuses are
constructed with pure silver
fuse elements, high purity
silica sand filler with
controlled grain size, an
inorganic core with spaced
arc suppressors, and a glass
melamine or glass epoxy
outer casing.

Current limiting action occurs
only when the current is
above the threshold current
for the fuse, that is, the
current is high enough to
melt the fuse elements)
before the peak value of
current is reached in the first
half cycle.

During a high fault current,
the silver element(s) melts
almost instantly losing energy
to the surrounding sand. The
energy melts the sand
forming a glass-like
substance commonly
referred to as “fulgurite.” The
arc voltage rapidly increases
to about three times the fuse
voltage rating, forcing the
current to zero. The fault
current is interrupted in onehalf cycle or less without
noise or expulsion of gases.

Low level currents are
cleared by the melting of a tin
solder drop on the fuse
element that in turn causes
the silver element to melt.
This is called the M-effect.
The silver element then burns
back until there is sufficient
internal gap to interrupt the
current.

The end studs of CXN fuses
are identical to the CX type.
However, CXN fuses have a
much higher C-rating, are
longer in physical length and
larger in diameter. The
diameters are 3 or 4 inches
depending on the ratings.

3
3
3

At 15 kV, the ranges are 45C
to 175C, with 120C, 150C
and 175C being achieved by
paralleling single barrel fuses.
The tested and approved
parallel ratings are specified
in the product selection
tables.

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
V14-T3-68

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

In some instances where the
required C-rating exceeds the
limits of CX fuses, it is
possible to move the live
parts to accommodate the
longer CXN fuse, and where
space and clearances present
no problem, the larger CXN
fuse can be substituted for a
CX fuse.

3.8

Current Limiting Fuses
CX, CXI and CXN Type Fuses

Product Selection

3

CX Type
CX Type

3
CX Type Current Limiting Fuses 4.3 kV Maximum (2.4 kV Nominal)
Diameter Length
Current
Interrupting Fuse
Rating
Barrel Rating rms Mounting Approximate Dimensions
in Inches (mm)
(Amperes) Number (kA Sym.)
Code

Approximate
Shipping
Weight
Lbs (kg)

Performance Curves
Minimum
Total
Melting
Clearing
Time
Time

3
Peak
Let-Through
Current
I2t

Catalog
Number

3
3

Non-Indicating
18C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544101 TC70544501 TC70544901 TC70545101 4CX-18C

25C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544101 TC70544501 TC70544901 TC70545101 4CX-25C

35C

1

50

G

2.00 (50.8)

10.00 (254.0)

1 (0.45)

TC70544101 TC70544501 TC70544901 TC70545101 4CX-35C

45C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544101 TC70544501 TC70544901 TC70545101 4CX-45C

50C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544101 TC70544501 TC70544901 TC70545101 4CX-50C

60C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544102 TC70544502 TC70544901 TC70545101 4CX-60C

65C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544102 TC70544501 TC70544901 TC70545101 4CX-65C

75C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544102 TC70544501 TC70544901 TC70545101 4CX-75C

3
3
3
3
3

80C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544102 TC70544502 TC70544901 TC70545101 4CX-80C

100C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544102 TC70544501 TC70544901 TC70545101 4CX-100C

3
3

Indicating
18C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544101 TC70544501 TC70544901 TC70545101 4CXI-18C

25C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544101 TC70544501 TC70544901 TC70545101 4CXI-25C

35C

1

50

G

2.00 (50.8)

10.00 (254.0)

1 (0.45)

TC70544101 TC70544501 TC70544901 TC70545101 4CXI-35C

45C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544101 TC70544501 TC70544901 TC70545101 4CXI-45C

50C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544101 TC70544501 TC70544901 TC70545101 4CXI-50C

60C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544102 TC70544502 TC70544901 TC70545101 4CXI-60C

65C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544102 TC70544501 TC70544901 TC70545101 4CXI-65C

75C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544102 TC70544501 TC70544901 TC70545101 4CXI-75C

80C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544102 TC70544502 TC70544901 TC70545101 4CXI-80C

100C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544102 TC70544501 TC70544901 TC70545101 4CXI-100C

3
3
3
3
3
3

CX Type Mountings and Hardware 4.3 kV Maximum (2.4 kV Nominal)
Mounting
(Including Live Parts, End Fittings) 

Live Parts
(Including End Fittings) 

End Fittings
(Disconnect Only)

Ampere
Rating

Fuse Mounting
Type 

Size

Voltage
BIL (kV)

Porcelain Insulator
Catalog Number

Glass-Polyester Insulator
Catalog Number

Catalog Number

Catalog Number

18C–100C

Non-disconnect

A

60

—

5CX-GNM-G

CX-NL

—

Disconnect

A

60

—

5CX-GDM-G

CX-DL

CX-DF

3
3
3
3

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3
3
3
3
3
3
3
3
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-69

3.8
3

CX Type

Current Limiting Fuses
CX, CXI and CXN Type Fuses

CX Type Current Limiting Fuses 5.5 kV Maximum (4.8 kV Nominal)

3

Diameter Length
Current
Interrupting Fuse
Rating
Barrel Rating rms Mounting Approximate Dimensions
(Amperes) Number (kA Sym.)
Code
in Inches (mm)

3

Non-Indicating

Performance Curves

Approximate
Shipping
Weight
Lbs (kg)

Minimum
Melting
Time

Total
Clearing
Time

Peak
Let-Through
I2t
Current

Catalog
Number

3

10C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544201 TC70544601 TC70544902 TC70545201 5CX-10C

12C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544201 TC70544601 TC70544902 TC70545201 5CX-12C

3

18C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544201 TC70544601 TC70544902 TC70545201 5CX-18C

20C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544201 TC70544601 TC70544902 TC70545201 5CX-20C

21C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544202 TC70544602 TC70544902 TC70545201 5CX-21C

25C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544201 TC70544601 TC70544902 TC70545201 5CX-25C

30C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544201 TC70544601 TC70544902 TC70545201 5CX-30C

3

35C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544202 TC70544602 TC70544902 TC70545201 5CX-35C

40C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544201 TC70544601 TC70544902 TC70545201 5CX-40C

3

50C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544201 TC70544601 TC70544902 TC70545201 5CX-50C

60C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544202 TC70544602 TC70544902 TC70545201 5CX-60C

65C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544201 TC70544601 TC70544902 TC70545201 5CX-65C

75C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544201 TC70544601 TC70544902 TC70545201 5CX-75C

3
3

3
3

Indicating

3

10C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544201 TC70544601 TC70544902 TC70545201 5CXI-10C

12C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544201 TC70544601 TC70544902 TC70545201 5CXI-12C

3

18C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544201 TC70544601 TC70544902 TC70545201 5CXI-18C

20C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544201 TC70544601 TC70544902 TC70545201 5CXI-20C

21C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544202 TC70544602 TC70544902 TC70545201 5CXI-21C

3

25C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544201 TC70544601 TC70544902 TC70545201 5CXI-25C

30C

1

50

G

1.13 (28.7)

10.00 (254.0)

1 (0.45)

TC70544201 TC70544601 TC70544902 TC70545201 5CXI-30C

3

35C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544202 TC70544602 TC70544902 TC70545201 5CXI-35C

40C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544201 TC70544601 TC70544902 TC70545201 5CXI-40C

50C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544201 TC70544601 TC70544902 TC70545201 5CXI-50C

60C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544202 TC70544602 TC70544902 TC70545201 5CXI-60C

65C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544201 TC70544601 TC70544902 TC70545201 5CXI-65C

75C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544201 TC70544601 TC70544902 TC70545201 5CXI-75C

3

3
3
3
3

CX Type Mountings and Hardware 5.5 kV Maximum (4.8 kV Nominal)

3

Mounting
(Including Live Parts, End Fittings) 

Live Parts
(Including End Fittings) 

End Fittings
(Disconnect Only)

3

Ampere
Rating

Fuse Mounting
Type 

Size

Voltage
BIL (kV)

Porcelain Insulator
Catalog Number

Glass-Polyester Insulator
Catalog Number

Catalog Number

Catalog Number

3

10C–75C

Non-disconnect

A

60

—

5CX-GNM-G

CX-NL

—

Disconnect

A

60

—

5CX-GDM-G

CX-DL

CX-DF

3

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3
3
3
3
3
3
V14-T3-70

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.8

Current Limiting Fuses
CX, CXI and CXN Type Fuses

CX Type

CX Type Current Limiting Fuses 8.3 kV Maximum (7.2 kV Nominal)
Diameter

Length

Current
Interrupting Fuse
Rating
Barrel Rating rms Mounting Approximate Dimensions
(Amperes) Number (kA Sym.)
Code
in Inches (mm)

3

Performance Curves

Approximate
Shipping
Weight
Lbs (kg)

Minimum
Melting
Time

Total
Clearing
Time

Peak
Let-Through
I2t
Current

Catalog
Number

3
3

Non-Indicating
3.5C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544302 TC70544702 TC70545001 TC70545301 8CX-3.5C

4C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544302 TC70544702 TC70545001 TC70545301 8CX-4C

4.5C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CX-4.5C

6C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CX-6C

7C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544302 TC70544702 TC70545001 TC70545301 8CX-7C

8C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CX-8C

10C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CX-10C

12C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CX-12C

15C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544302 TC70544702 TC70545001 TC70545301 8CX-15C

18C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CX-18C

20C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CX-20C

25C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CX-25C

30C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CX-30C

35C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544302 TC70544702 TC70545001 TC70545301 8CX-35C

40C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CX-40C

3
3

Indicating
3.5C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544302 TC70544702 TC70545001 TC70545301 8CXI-3.5C

4C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544302 TC70544702 TC70545001 TC70545301 8CXI-4C

4.5C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CXI-4.5C

6C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CXI-6C

7C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544302 TC70544702 TC70545001 TC70545301 8CXI-7C

8C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CXI-8C

10C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CXI-10C

12C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CXI-12C

15C

1

50

G

1.13 (28.7)

10.00 (254.0)

2 (0.91)

TC70544302 TC70544702 TC70545001 TC70545301 8CXI-15C

18C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CXI-18C

20C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CXI-20C

25C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CXI-25C

30C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CXI-30C

35C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544302 TC70544702 TC70545001 TC70545301 8CXI-35C

40C

1

50

G

2.00 (50.8)

10.00 (254.0)

2 (0.91)

TC70544301 TC70544701 TC70545001 TC70545301 8CXI-40C

3
3
3
3
3
3
3
3

3
3
3
3
3
3
3
3
3

CX Type Mountings and Hardware 8.3 kV Maximum (7.2 kV Nominal)

Ampere
Rating
3.5C–40C

Fuse Mounting
Type 

Size

Mounting
(Including Live Parts, End Fittings) 

Live Parts
(Including End Fittings) 

End Fittings
(Disconnect Only)

Voltage
BIL (kV)

Porcelain Insulator
Catalog Number

Glass-Polyester Insulator
Catalog Number

Catalog Number

Catalog Number

3
3

Non-disconnect

B

75

—

8CX-GNM-G

CX-NL

—

Disconnect

B

75

—

8CX-GDM-G

CX-DL

CX-DF

3
3

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3
3
3
3
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-71

3.8
3

CX Type

Current Limiting Fuses
CX, CXI and CXN Type Fuses

CX Type Current Limiting Fuses 15.5 kV Maximum (14.4 kV Nominal)

3

Diameter Length
Current
Interrupting Fuse
Rating
Barrel Rating rms Mounting Approximate Dimensions
in Inches (mm)
(Amperes) Number (kA Sym.)
Code

3

Non-Indicating

Approximate
Shipping
Weight
Lbs (kg)

Performance Curves
Minimum
Total
Melting
Clearing
Time
Time

Peak
Let-Through
Current
I2t

Catalog
Number

3

4C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CX-4C

6C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CX-6C

3

7C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544402 TC70544802 TC70545002 TC70545401 15CX-7C

8C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CX-8C

10C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CX-10C

12C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CX-12C

15C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544402 TC70544802 TC70545002 TC70545401 15CX-15C

3

18C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CX-18C

20C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CX-20C

3

25C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CX-25C

30C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CX-30C

40C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CX-40C

3
3

3

Indicating

3

4C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CXI-4C

3

6C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CXI-6C

7C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544402 TC70544802 TC70545002 TC70545401 15CXI-7C

3

8C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CXI-8C

10C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CXI-10C

12C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CXI-12C

3

15C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544402 TC70544802 TC70545002 TC70545401 15CXI-15C

18C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CXI-18C

3

20C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CXI-20C

25C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CXI-25C

30C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CXI-30C

40C

1

50

G

2.00 (50.8)

14.30 (363.2)

2 (0.91)

TC70544401 TC70544801 TC70545002 TC70545401 15CXI-40C

3

3
3
3

CX Type Mountings and Hardware 15.5 kV Maximum (14.4 kV Nominal)

3
3
3
3

Mounting
(Including Live Parts, End Fittings) 

Live Parts
(Including End Fittings) 

End Fittings
(Disconnect Only)

Ampere
Rating

Fuse Mounting
Type 

Size

Voltage
BIL (kV)

Porcelain Insulator
Catalog Number

Glass-Polyester Insulator
Catalog Number

Catalog Number

Catalog Number

4C–40C

Non-disconnect

C

95

—

15CX-GNM-G

CX-NL

—

Disconnect

C

95

—

15CX-GDM-G

CX-DL

CX-DF

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3
3
3
3
3
3
3
V14-T3-72

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.8

Current Limiting Fuses
CX, CXI and CXN Type Fuses

CXN Type
Type CXN

3
CXN Type Current Limiting Fuses 8.3 kV Maximum (7.2 kV Nominal)
Diameter

Length

Current
Rating
(Amperes)

Barrel
Number

Interrupting
Rating
rms (kA Sym.)

Approximate Dimensions
in Inches (mm)

Approximate
Shipping
Weight
Lbs (kg)

Performance Curves
Minimum
Total
Melting
Clearing
Time
Time

3
Peak
Let-Through
Current

Catalog
Number

60C

1

50

3.00 (76.2)

18.80 (477.5)

8 (3.63)

TC66675102 TC66675202 TC66664902

8CXN-60C

100C

1

50

3.00 (76.2)

18.80 (477.5)

8 (3.63)

TC66675102 TC66675202 TC66664902

8CXN-100C

125C

1

50

4.00 (101.6)

18.80 (477.5)

14 (6.36)

TC66675102 TC66675202 TC66664902

8CXN-125C

150C

1

50

4.00 (101.6)

18.80 (477.5)

14 (6.36)

TC66675102 TC66675202 TC66664902

8CXN-150C

200C

1

50

4.00 (101.6)

18.80 (477.5)

14 (6.36)

TC66675102 TC66675202 TC66664902

8CXN-200C

250C

1

50

4.00 (101.6)

18.80 (477.5)

14 (6.36)

TC66675102 TC66675202 TC66664902

120C

2

50

3.00 (76.2)

18.80 (477.5)

16 (7.26)

TC66675104 TC66675204 TC66664902

2 X 60C

8CXN-120C

200C

2

50

3.00 (76.2)

18.80 (477.5)

16 (7.26)

TC66675104 TC66675204 TC66664902

2 X 100C

8CXN-200C

250C

2

50

3.00 (76.2)

18.80 (477.5)

16 (7.26)

TC66675104 TC66675204 TC66664902

2 X 125C

8CXN-250C

300C

2

50

4.00 (101.6)

18.80 (477.5)

28 (12.71)

TC66675104 TC66675204 TC66664902

2 X 150C

8CXN-300C

8CXN-250C

3
3
3
3
3
3
3
3

CXN Type Mountings and Hardware 8.3 kV Maximum (7.2 kV Nominal)
Fuse Mounting
Type 

Voltage
LIWL (BIL)

Glass Polyester Insulator Mounting
(Including Live Parts, End Fittings) 
Catalog Number

Non-disconnect

95

15CXN-GNM-D

15CXN-NL-D

—

Non-disconnect

95

15CXN-GNM-G

15CXN-NL-G

—

Disconnect

95

15CXN-GDM-G

15CXN-DL-G

15CXN-DF-G

Non-disconnect

95

15CXN-GNM-F

15CXN-NL-F

—

Non-disconnect

95

15CXN-GNM-G

15CXN-NL-G

—

Disconnect

95

25CXN-GDM-G

15CXN-DL-G

15CXN-DF-G

120C, 200C
Double barrel

Non-disconnect

95

15CXN-GNM-D

15CXN-NL-D

—

250C, 300C
Double barrel

Non-disconnect

95

15CXN-GNM-F

15CXN-NL-F

—

Ampere Rating
60C–100C
Single barrel

125C–250C
Single barrel

Catalog Number

End Fittings
(Disconnect Only)
Catalog Number

Live Parts



3
3
3
3
3
3
3
3

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

3
3
3
3
3
3
3
3
3
3
3
3
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-73

3.8
3

CXN Type

Current Limiting Fuses
CX, CXI and CXN Type Fuses

CXN Type Current Limiting Fuses 15.5 kV Maximum (14.4 kV Nominal)
Diameter

Approximate Dimensions
in Inches (mm)

Approximate
Shipping
Weight
Lbs (kg)

Performance Curves
Minimum
Total
Melting
Clearing
Time
Time

50

3.00 (76.2)

18.80 (477.5)

8 (3.63)

TC66674802 TC66675002 TC66665002

15CXN-45C

50

3.00 (76.2)

18.80 (477.5)

8 (3.63)

TC66674802 TC66675002 TC66665002

15CXN-60C

1

50

4.00 (101.6)

18.80 (477.5)

14 (6.36)

TC66674802 TC66675002 TC66665002

15CXN-75C

85C

1

50

4.00 (101.6)

18.80 (477.5)

14 (6.36)

TC66674802 TC66675002 TC66665002

15CXN-85C

100C

1

50

4.00 (101.6)

18.80 (477.5)

14 (6.36)

TC66674802 TC66675002 TC66665002

90C

2

50

3.00 (76.2)

18.80 (477.5)

16 (7.26)

TC66674804 TC66675004 TC66665002

2 X 45C

15CXN-90C

120C

2

50

3.00 (76.2)

18.80 (477.5)

16 (7.26)

TC66674804 TC66675004 TC66665002

2 X 60C

15CXN-120C

150C

2

50

4.00 (101.6)

18.80 (477.5)

28 (12.71)

TC66674804 TC66675004 TC66665002

2 X 75C

15CXN-150C

175C

2

50

4.00 (101.6)

18.80 (477.5)

28 (12.71)

TC66674804 TC66675004 TC66665002

2 X 85C

15CXN-175C

3

Current
Rating
(Amperes)

Barrel
Number

Interrupting
Rating
rms (kA Sym.)

3

45C

1

3

60C

1

75C

3
3
3
3
3

Length

Peak
Let-Through
Current

Catalog
Number

15CXN-100C

CXN Type Mountings and Hardware 15.5 kV Maximum (14.4 kV Nominal)

3

Fuse Mounting
Type 

Voltage
LIWL (BIL)

Glass Polyester Insulator Mounting
(Including Live Parts, End Fittings) 
Catalog Number

Catalog Number

End Fittings
(Disconnect Only)
Catalog Number

Non-disconnect

95

15CXN-GNM-D

15CXN-NL-D

—

Non-disconnect

95

15CXN-GNM-G

15CXN-NL-G

—

Disconnect

95

15CXN-GDM-G

15CXN-DL-G

15CXN-DF-G

Non-disconnect

95

15CXN-GNM-F

15CXN-NL-F

—

Non-disconnect

95

15CXN-GNM-G

15CXN-NL-G

—

Disconnect

95

25CXN-GDM-G

15CXN-DL-G

15CXN-DF-G

3

90C, 120C
Double barrel

Non-disconnect

95

15CXN-GNM-D

15CXN-NL-D

—

3

150C, 175C
Double barrel

Non-disconnect

95

15CXN-GNM-F

15CXN-NL-F

—

3

Notes
 See Page V14-T3-38 for diagram of typical mounting.
 End fittings supplied only when required.

Ampere Rating

3

45C–60C
Single barrel

3
3

75C–100C
Single barrel

3

3
3
3
3
3
3
3
3
3
3
3
3
3
V14-T3-74

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Live Parts 

3.8

Current Limiting Fuses
CX, CXI and CXN Type Fuses

Dimensions

3

Approximate Dimensions in Inches (mm).
CXN Type Fuse
C Dia.

0.625 (15.9) Dia.
(Both ends)
1.85 (47.0) 1.85 (47.0)
B ± 0.09 (22.9)
A ± 0.09 (22.9)

1.19
(30.2)

3

CXN Type Fuse Dimensional Details
Maximum
kV

Ampere
Rating

1.21 Ref.
w/Indicator

8.3
8.3

1.19 (30.2) Ref.
w/o Indicator

15.5
15.5

3

Dimensions
A

B

C

60–100
125–250

18.86 (479.0)
18.86 (479.0)

16.41 (416.8)
16.41 (416.8)

3.00 (76.2)
4.00 (101.6)

45–60
75–100

18.86 (479.0)
18.86 (479.0)

18.86 (479.0)
18.86 (479.0)

3.00 (76.2)
4.00 (101.6)

CX Type Fuse

3
3
3
3

0.625 (15.9) Dia.

3

1.13 (28.7) Dia.
8.00 (203.2) ± 0.06 (1.5)
10.00 (254.0) ± 0.09 (2.3)

3

1.00 (25.4)

0.625 (15.9) Ref.

3

2.00 (50.8) Dia.

8.00 (203.2) ± 0.06 (1.5)
10.00 (254.0) ± 0.09 (2.3)

3

1.00 (25.4)

3
3
3

2.12 (53.8) Dia.

1.00 (25.4)
8.00 (203.2) ± 0.06 (1.5)

3

1.06 (26.9)

3

10.00 (257.0) ± 0.09 (2.3)

3
3
3
3
3
3
3
3
3
3
3
3
3
3
Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-75

3.9
3

Current Limiting Fuses
DSL, MDSL and NPL Type Low Voltage Current Limiters

Contents

DSL Current Limiters

Description

3
3
3
3
3
3
3
3
3
3

DSL, MDSL and NPL Type Low Voltage Current Limiters

3

Product Description

3
3

Page

DSL, MDSL and NPL Type Low Voltage Current Limiters
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
V14-T3-77

Refer to DSL, Magnum™
DSL or NPL sections of this
catalog for product
description and application
guidelines.

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
V14-T3-76

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

3.9

Current Limiting Fuses
DSL, MDSL and NPL Type Low Voltage Current Limiters

Product Selection

3

The following current limiters are available as renewal/replacement parts for use in conjunction
with DLL, MDSL low voltage power circuit breakers, and network protectors.

3

Types DSL, MDSL and NPL
Maximum Design
Voltage

Interrupting Rating
(kA Sym.)

Catalog Number

Style Number

Approx. Shipping Weight
Lbs (kg)
Average Melting Time

Peak Let-Through
Current

600

200

6DSL-A150

140D816G01

3.00 (1.4)

TC63977102

TC63977202

600

200

6DSL-A200

140D816G02

3.00 (1.4)

TC63977102

TC63977202

600

200

6DSL-A250

140D816G03

3.00 (1.4)

TC63977102

TC63977202

600

200

6DSL-A300

140D816G04

3.00 (1.4)

TC63977102

TC63977202

600

200

6DSL-A400

140D816G05

3.00 (1.4)

TC63977102

TC63977202

600

200

6DSL-A600

140D816G06

3.00 (1.4)

TC63977102

TC63977202

600

200

6DSL-A800

140D816G07

3.00 (1.4)

TC63977102

TC63977202

600

200

6DSL-B1200

140D816G10

4.00 (1.8)

TC63977102

TC63977202

600

200

6DSL-B1600

140D816G11

4.00 (1.8)

TC63977102

TC63977202

600

200

6DSL-B3000

140D816G12

4.00 (1.8)

TC63977102

TC63977202

600

200

6DSL-C800

151D982G01

5.50 (2.5)

TC63943102

TC63943202

600

200

6DSL-C1000

151D982G02

5.50 (2.5)

TC63943102

TC63943202

600

200

6DSL-C1200

151D982G03

5.50 (2.5)

TC63943102

TC63943202

600

200

6DSL-C1600

151D982G04

5.50 (2.5)

TC63943102

TC63943202

600

200

6DSL-C2000

151D982G05

5.50 (2.5)

TC63943102

TC63943202

600

200

6DSL-D2500

151D982G09

8.50 (3.9)

TC63943102

TC63943202

600

200

6DSL-D3000

151D982G10

8.50 (3.9)

TC63943102

TC63943202

600

200

6DSL-E2500

5980C01G01

20.0 (9.1)

TC70550302

TC70550402

600

200

6DSL-E3000

5980C01G02

20.0 (9.1)

TC70550302

TC70550402

600

200

6DSL-E4000

5980C01G03

20.0 (9.1)

TC70550302

TC70550402

600

200

6DSL-F5000

5980C01G04

24.0 (10.9)

TC70550302

TC70550402

600

200

6MDSL-MA150

5982C90G01

3.00 (1.4)

TC63977103

TC63977202

600

200

6MDSL-MA200

5982C90G02

3.00 (1.4)

TC63977103

TC63977202

600

200

6MDSL-MA250

5982C90G03

3.00 (1.4)

TC63977103

TC63977203

600

200

6MDSL-MA300

5982C90G04

3.00 (1.4)

TC63977103

TC63977203

600

200

6MDSL-MA400

5982C90G05

3.00 (1.4)

TC63977103

TC63977203

600

200

6MDSL-MA600

5982C90G07

3.00 (1.4)

TC63977103

TC63977203

600

200

6MDSL-MA800

5982C90G08

3.00 (1.4)

TC63977103

TC63977203

600

200

6MDSL-MB-1200

5981C91G01

4.00 (1.8)

TC63977103

TC63977203

600

200

6MDSL-MB-1600

5981C91G02

4.00 (1.8)

TC63977103

TC63977203

600

200

6MDSL-MB-2000

5981C91G03

4.00 (1.8)

TC63977103

TC63977203

600

200

6MDSL-MC-800

5981C92G01

5.50 (2.5)

TC63943102

TC63943202

600

200

6MDSL-MC-1000

5981C92G02

5.50 (2.5)

TC63943102

TC63943202

600

200

6MDSL-MC-1200

5981C92G03

5.50 (2.5)

TC63943102

TC63943202

600

200

6MDSL-MC-1600

5981C92G04

5.50 (2.5)

TC63943102

TC63943202

600

200

6MDSL-MC-2000

5981C92G05

5.50 (2.5)

TC63943102

TC63943202

600

200

6MDSL-MD2500

5981C93G01

8.50 (3.9)

TC63977103

TC63977203

600

200

6MDSL-MD3000

5981C93G02

8.50 (3.9)

TC63977103

TC63977203

480

150

4NPL-900

140D318G04

—

TC63942802

TC63942803

480

150

4NPL-1300

140D318G05

—

TC63942803

TC63942803

480

150

4NPL-1875

140D318G01

—

TC63942804

TC63942803

480

150

4NPL-2000

140D318G07

—

TC63942805

TC63942803

480

150

4NPL-2825

140D318G02

—

TC63942806

TC63942803

480

150

4NPL-3000

140D318G06

—

TC63942807

TC63942803

480

200

4NPL-3500

5982C64G01

—

TC70550306

—

480

200

4NPL-5000

5982C64G02

—

TC70550306

—

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-T3-77

Appendix 1—Eaton Terms & Conditions
Effective Date: November 1, 2008

Contents

Eaton Terms & Conditions

Description

Page

Terms and Conditions of Sale . . . . . . . . . . . . . . . . .
Terms of Payment . . . . . . . . . . . . . . . . . . . . . . . . .
Freight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V14-A1-1
V14-A1-2
V14-A1-3
V14-A1-3

Selling Policy (Supersedes Selling Policy 25-000, dated February 20, 2006)
Terms and Conditions of Sale
The Terms and Conditions of
Sale set forth herein, and any
supplements which may be
attached hereto, constitute
the full and final expression
of the contract for the sale
of products or services
(hereinafter referred to as
Product(s) or Services by
Eaton Corporation
(hereinafter referred to as
Seller) to the Buyer, and
supersedes all prior
quotations, purchase orders,
correspondence or
communications whether
written or oral between the
Seller and the Buyer.
Notwithstanding any contrary
language in the Buyer’s
purchase order,
correspondence or other
form of acknowledgment,
Buyer shall be bound by
these Terms and Conditions
of Sale when it sends a
purchase order or otherwise
indicates acceptance of this
contract, or when it accepts
delivery from Seller of the
Products or Services.

THE CONTRACT FOR SALE
OF THE PRODUCTS OR
SERVICES IS EXPRESSLY
LIMITED TO THE TERMS
AND CONDITIONS OF SALE
STATED HEREIN. ANY
ADDITIONAL OR DIFFERENT
TERMS PROPOSED BY
BUYER ARE REJECTED
UNLESS EXPRESSLY
AGREED TO IN WRITING BY
SELLER. No contract shall
exist except as herein
provided.
Complete Agreement
No amendment or
modification hereto nor any
statement, representation or
warranty not contained herein
shall be binding on the Seller
unless made in writing by an
authorized representative of
the Seller. Prior dealings,
usage of the trade or a course
of performance shall not be
relevant to determine the
meaning of this contract even
though the accepting or
acquiescing party had
knowledge of the nature
of the performance and
opportunity for objection.

Quotations
Written quotations are valid
for 30 days from its date
unless otherwise stated in
the quotation or terminated
sooner by notice.
Verbal quotations, unless
accepted, expire the same
day they are made.
A complete signed order
must be received by Seller
within 20 calendar days of
notification of award,
otherwise the price and
shipment will be subject to
re-negotiation.

Termination and Cancellation
Any order may be terminated
by the Buyer only by written
notice and upon payment
of reasonable termination
charges, including all costs
plus profit.
Seller shall have the right to
cancel any order at any time
by written notice if Buyer
breaches any of the terms
hereof, becomes the subject
of any proceeding under state
or federal law for the relief
of debtors, or otherwise
becomes insolvent or
bankrupt, generally does not
pay its debts as they become
due or makes an assignment
for the benefit of creditors.

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A1-1

Appendix 1—Eaton Terms & Conditions
Effective Date: November 1, 2008

Prices
All prices are subject to
change without notice. In the
event of a price change, the
effective date of the change
will be the date of the new
price or discount sheet, letter
or telegram. All quotations
made or orders accepted
after the effective date will be
on the new basis. For existing
orders, the price of the
unshipped portion of an order
will be the price in effect at
time of shipment.
Price Policy—Products and
Services
When prices are quoted as
firm for quoted shipment, they
are firm provided the following
conditions are met:
1. The order is released
with complete
engineering details.
2. Shipment of Products
are made, and Services
purchased are provided
within the quoted
lead time.
3. When drawings for
approval are required
for any Products, the
drawings applicable to
those Products must be
returned within 30*
calendar days from the
date of the original
mailing of the drawings
by Seller. The return
drawings must be
released for manufacture
and shipment and must
be marked “APPROVED”
or “APPROVED AS
NOTED.” Drawing
re-submittals which are
required for any other
reason than to correct
Seller errors will not
extend the 30-day
period.

If the Buyer initiates or in
any way causes delays
in shipment, provision of
Services or return of approval
drawings beyond the periods
stated above, the price of the
Products or Services will be
increased 1% per month
or fraction thereof up to a
maximum of 18 months from
the date of the Buyer’s order.
For delays resulting in
shipment or provision of
Services beyond 18 months
from the date of the Buyer’s
order, the price must be
renegotiated.
Price Policy—BLS
Refer to Price Policy 25-050.
Minimum Billing
Orders less than $1,000 will
be assessed a shipping and
handling charge of 5% of the
price of the order, with a
minimum charge of $25.00
unless noted differently on
Product discount sheets.
Taxes
The price does not include
any taxes. Buyer shall be
responsible for the payment
of all taxes applicable to, or
arising from the transaction,
the Products, its sale, value,
or use, or any Services
performed in connection
therewith regardless of
the person or entity
actually taxed.

Terms of Payment
Products
Acceptance of all orders is
subject to the Buyer meeting
Seller’s credit requirements.
Terms of payment are
subject to change for failure
to meet such requirements.
Seller reserves the right at
any time to demand full or
partial payment before
proceeding with a contract of
sale as a result of changes in
the financial condition of the
Buyer. Terms of Payment are
either Net 30 days from the
date of invoice of each
shipment or carry a cash
discount based on Product
type. Specific payment terms
for Products are outlined in
the applicable Product
discount schedules.
Services
Terms of payment are net
within 30 days from date of
invoice for orders amounting
to less than $50,000.00.
Terms of payment for orders
exceeding $50,000.00 shall
be made according to the
following:
1. Twenty percent (20%) of
order value with the
purchase order payable
30 days from date of
invoice.
2. Eighty percent (80%) of
order value in equal
monthly payments over
the performance period
payable 30 days from
date of invoice.

* 60 days for orders
through contractors
to allow time for their
review and approval
before and after
transmitting them
to their customers.

V14-A1-2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Except for work performed (i)
under a firm fixed price basis
or (ii) pursuant to terms of a
previously priced existing
contract between Seller and
Buyer, invoices for work
performed by Seller shall
have added and noted on
each invoice a charge of 3%
(over and above the price of
the work) which is related
to Seller compliance with
present and proposed
environmental, health, and
safety regulations associated
with prescribed requirements
covering hazardous materials
management and employee
training, communications,
personal protective
equipment, documentation
and record keeping
associated therewith.
Adequate Assurances
If, in the judgment of Seller,
the financial condition of the
Buyer, at any time during the
period of the contract, does
not justify the terms of
payment specified, Seller
may require full or partial
payment in advance.
Delayed Payment
If payments are not made in
accordance with these terms,
a service charge will, without
prejudice to the right of Seller
to immediate payment, be
added in an amount equal to
the lower of 1.5% per month
or fraction thereof or the
highest legal rate on the
unpaid balance.

Appendix 1—Eaton Terms & Conditions
Effective Date: November 1, 2008

Freight
Freight policy will be listed on
the Product discount sheets,
or at option of Seller one of
the following freight terms
will be quoted.
F.O.B.—P/S—Frt./Ppd. and
Invoiced
Products are sold F.O.B.
point of shipment freight
prepaid and invoiced to the
Buyer.
F.O.B.—P/S—Frt./Ppd.
and Allowed
Products sold are delivered
F.O.B. point of shipment,
freight prepaid and included
in the price.
F.O.B. Destination—Frt./Ppd.
and Allowed
At Buyer’s option, Seller will
deliver the Products F.O.B.
destination freight prepaid
and 2% will be added to the
net price.
The term “freight prepaid”
means that freight charges
will be prepaid to the
accessible common carrier
delivery point nearest the
destination for shipments
within the United States and
Puerto Rico unless noted
differently on the Product
discount sheets. For any
other destination contact
Seller’s representative.
Shipment and Routing
Seller shall select the point of
origin of shipment, the
method of transportation, the
type of carrier equipment and
the routing of the shipment.
If the Buyer specifies a
special method of
transportation, type of carrier
equipment, routing, or
delivery requirement, Buyer
shall pay all special freight
and handling charges.
When freight is included in
the price, no allowance will
be made in lieu of
transportation if the Buyer
accepts shipment at factory,
warehouse, or freight station
or otherwise supplies its own
transportation.

Warranty
Risk of Loss
Risk of loss or damage to the
Products shall pass to Buyer
at the F.O.B. point.
Concealed Damage
Except in the event of F.O.B.
destination shipments, Seller
will not participate in any
settlement of claims for
concealed damage.
When shipment has been
made on an F.O.B. destination
basis, the Buyer must unpack
immediately and, if damage is
discovered must:
1. Not move the Products
from the point of
examination.
2. Retain shipping container
and packing material.
3. Notify the carrier in
writing of any apparent
damage.
4. Notify Seller
representative within
72 hours of delivery.
5. Send Seller a copy of
the carrier’s inspection
report.
Witness Tests/Customer
Inspection
Standard factory tests may
be witnessed by the Buyer
at Seller’s factory for an
additional charge calculated
at the rate of $2,500 per day
(not to exceed eight (8) hours)
per Product type. Buyer may
final inspect Products at the
Seller’s factory for $500 per
day per Product type.
Witness tests will add one (1)
week to the scheduled
shipping date. Seller will
notify Buyer fourteen (14)
calendar days prior to
scheduled witness testing
or inspection. In the event
Buyer is unable to attend, the
Parties shall mutually agree
on a rescheduled date.
However, Seller reserves
the right to deem the witness
tests waived with the right to
ship and invoice Products.

Held Orders
For any order held, delayed
or rescheduled at the request
of the Buyer, Seller may, at
its sole option (1) require
payment to be based on any
reasonable basis, including
but not limited to the contract
price, and any additional
expenses, or cost resulting
from such a delay; (2) store
Products at the sole cost and
risk of loss of the Buyer; and/
or (3) charge to the Buyer
those prices under the
applicable price policy.
Payment for such price,
expenses and costs, in any
such event, shall be due by
Buyer within thirty (30) days
from date of Seller’s invoice.
Any order so held delayed or
rescheduled beyond six (6)
months will be treated as a
Buyer termination.

Warranty for Products
Seller warrants that the
Products manufactured by
it will conform to Seller’s
applicable specifications and
be free from failure due to
defects in workmanship and
material for one (1) year from
the date of installation of
the Product or eighteen (18)
months from the date of
shipment of the Product,
whichever occurs first.

Drawing Approval
Seller will design the
Products in line with, in
Seller’s judgment, good
commercial practice. If at
drawing approval Buyer
makes changes outside of
the design as covered in their
specifications, Seller will then
be paid reasonable charges
and allowed a commensurate
delay in shipping date based
on the changes made.

Seller requires all nonconforming Products be
returned at Seller’s expense
for evaluation unless
specifically stated otherwise
in writing by Seller.

Drawing Re-Submittal
When Seller agrees to do so
in its quotation, Seller shall
provide Buyer with the first
set of factory customer
approval drawing(s) at Seller’s
expense. The customer
approval drawing(s) will be
delivered at the quoted
delivery date. If Buyer
requests drawing changes
or additions after the initial
factory customer approval
drawing(s) have been
submitted by Seller, the
Seller, at its option, may
assess Buyer drawing
charges. Factory customer
approval drawing changes
required due to
misinterpretation by Seller
will be at Seller’s expense.
Approval drawings generated
by Bid Manager are excluded
from this provision.

Volume 14—Fuses

www.comoso.com

In the event any Product fails
to comply with the foregoing
warranty Seller will, at its
option, either (a) repair or
replace the defective
Product, or defective part or
component thereof, F.O.B.
Seller’s facility freight
prepaid, or (b) credit Buyer
for the purchase price of the
Product. All warranty claims
shall be made in writing.

This warranty does not
cover failure or damage
due to storage, installation,
operation or maintenance not
in conformance with Seller’s
recommendations and
industry standard practice
or due to accident, misuse,
abuse or negligence. This
warranty does not cover
reimbursement for labor,
gaining access, removal,
installation, temporary power
or any other expenses, which
may be incurred in connection
with repair or replacement.
This warranty does not
apply to equipment not
manufactured by Seller.
Seller limits itself to
extending the same warranty
it receives from the supplier.

CA08100016E—August 2011 www.eaton.com

V14-A1-3

Appendix 1—Eaton Terms & Conditions
Effective Date: November 1, 2008

Extended Warranty for Products
If requested by the Buyer and
specifically accepted in
writing by Seller, the
foregoing standard warranty
for Products will be extended
from the date of shipment for
the period and price indicated
below:
●

●

●

24 months—2% of
Contract Price
30 months—3% of
Contract Price
36 months—4% of
Contract Price

Special Warranty (In and Out)
for Products
If requested by the Buyer
and specifically accepted in
writing by Seller, Seller will,
during the warranty period
for Products, at an additional
cost of 2% of the contract
price, be responsible for the
direct cost of:
1. Removing the Product
from the installed
location.
2. Transportation to the
repair facility and return
to the site.
3. Reinstallation on site.
The total liability of Seller for
this Special Warranty for
Products is limited to 50%
of the contract price of the
particular Product being
repaired and excludes
expenses for removing
adjacent apparatus, walls,
piping, structures, temporary
service, etc.

V14-A1-4

Warranty for Services
Seller warrants that the
Services performed by it
hereunder will be performed
in accordance with generally
accepted professional
standards.
The Services, which do not
so conform, shall be
corrected by Seller upon
notification in writing by the
Buyer within one (1) year
after completion of the
Services.
Unless otherwise agreed to
in writing by Seller, Seller
assumes no responsibility
with respect to the suitability
of the Buyer’s, or its
customer’s, equipment or
with respect to any latent
defects in equipment not
supplied by Seller. This
warranty does not cover
damage to Buyer’s, or its
customer’s, equipment,
components or parts
resulting in whole or in part
from improper maintenance
or operation or from their
deteriorated condition. Buyer
will, at its cost, provide Seller
with unobstructed access
to the defective Services,
as well as adequate free
working space in the
immediate vicinity of the
defective Services and such
facilities and systems,
including, without limitation,
docks, cranes and utility
disconnects and connects,
as may be necessary in order
that Seller may perform its
warranty obligations. The
conducting of any tests shall
be mutually agreed upon and
Seller shall be notified of, and
may be present at, all tests
that may be made.

Warranty for Power Systems
Studies
Seller warrants that any
power systems studies
performed by it will conform
to generally accepted
professional standards. Any
portion of the study, which
does not so conform, shall
be corrected by Seller upon
notification in writing by the
Buyer within six (6) months
after completion of the study.
All warranty work shall be
performed in a single shift
straight time basis Monday
through Friday. In the event
that the study requires
correction of warranty items
on an overtime schedule,
the premium portion of such
overtime shall be for the
Buyer’s account.
Limitation on Warranties for
Products, Services and Power
Systems Studies
THE FOREGOING
WARRANTIES ARE
EXCLUSIVE EXCEPT FOR
WARRANTY OF TITLE.
SELLER DISCLAIMS ALL
OTHER WARRANTIES
INCLUDING ANY IMPLIED
WARRANTIES OF
MERCHANTABILITY
AND FITNESS FOR A
PARTICULAR PURPOSE.
CORRECTION OF NONCONFORMITIES IN THE
MANNER AND FOR THE
PERIOD OF TIME PROVIDED
ABOVE SHALL CONSTITUTE
SELLER’S SOLE LIABILITY
AND BUYER’S EXCLUSIVE
REMEDY FOR FAILURE OF
SELLER TO MEET ITS
WARRANTY OBLIGATIONS,
WHETHER CLAIMS OF
THE BUYER ARE BASED
IN CONTRACT, IN TORT
(INCLUDING NEGLIGENCE
OR STRICT LIABILITY), OR
OTHERWISE.

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Asbestos
Federal Law requires that
building or facility owners
identify the presence,
location and quantity of
asbestos containing material
(hereinafter “ACM”) at work
sites. Seller is not licensed to
abate ACM. Accordingly, for
any contract which includes
the provision of Services,
prior to (i) commencement of
work at any site under a
specific Purchase Order, (ii) a
change in the work scope of
any Purchase Order, the
Buyer will certify that the
work area associated with
the Seller’s scope of work
includes the handling of Class
II ACM, including but not
limited to generator wedges
and high temperature gaskets
which include asbestos
materials. The Buyer shall, at
its expense, conduct
abatement should the
removal, handling,
modification or reinstallation,
or some or all of them, of said
Class II ACM be likely to
generate airborne asbestos
fibers; and should such
abatement affect the cost
of or time of performance
of the work then Seller shall
be entitled to an equitable
adjustment in the schedule,
price and other pertinent
affected provisions of
the contract.
Compliance with Nuclear
Regulation
Seller’s Products are sold as
commercial grade Products
not intended for application in
facilities or activities licensed
by the United States Nuclear
Regulatory Commission for
atomic purposes. Further
certification will be required
for use of the Products in any
safety-related application in
any nuclear facility licensed
by the U.S. Nuclear
Regulatory Commission.

Appendix 1—Eaton Terms & Conditions
Effective Date: November 1, 2008

Returning Products
Authorization and shipping
instructions for the return
of any Products must be
obtained from Seller before
returning the Products.
When return is occasioned
due to Seller error, full credit
including all transportation
charges will be allowed.
Product Notices
Buyer shall provide the user
(including its employees) of
the Products with all Seller
supplied Product notices,
warnings, instructions,
recommendations, and
similar materials.
Force Majeure
Seller shall not be liable for
failure to perform or delay
in performance due to fire,
flood, strike or other labor
difficulty, act of God, act of
any governmental authority or
of the Buyer, riot, embargo,
fuel or energy shortage, car
shortage, wrecks or delays in
transportation, or due to any
other cause beyond Seller’s
reasonable control. In the
event of delay in performance
due to any such cause, the
date of delivery or time for
completion will be extended
by a period of time reasonably
necessary to overcome the
effect of such delay.
Liquidated Damages
Contracts which include
liquidated damage clauses for
failure to meet shipping or job
completion promises are not
acceptable or binding on
Seller, unless such clauses
are specifically accepted in
writing by an authorized
representative of the Seller at
its headquarters office.

Patent Infringement
Seller will defend or, at its
option, settle any suit or
proceeding brought against
Buyer, or Buyer’s customers,
to the extent it is based upon
a claim that any Product or
part thereof, manufactured by
Seller or its subsidiaries and
furnished hereunder,
infringes any United States
patent, other than a claim of
infringement based upon use
of a Product or part thereof in
a process, provided Seller is
notified in reasonable time
and given authority,
information and assistance
(at Seller’s expense) for the
defense of same. Seller shall
pay all legal and court costs
and expenses and courtassessed damages awarded
therein against Buyer
resulting from or incident to
such suit or proceeding. In
addition to the foregoing, if at
any time Seller determines
there is a substantial question
of infringement of any United
States patent, and the use of
such Product is or may be
enjoined, Seller may, at its
option and expense: either (a)
procure for Buyer the right to
continue using and selling the
Product; (b) replace the
Product with non-infringing
apparatus; (c) modify the
Product so it becomes noninfringing; or (d) as a last
resort, remove the Product
and refund the purchase
price, equitably adjusted for
use and obsolescence. In no
case does Seller agree to pay
any recovery based upon its
Buyer’s savings or profit
through use of Seller’s
Products whether the use be
special or ordinary. The
foregoing states the entire
liability of Seller for patent
infringement.

The preceding paragraph
does not apply to any claim of
infringement based upon: (a)
any modification made to a
Product other than by Seller;
(b) any design and/or
specifications of Buyer to
which a Product was
manufactured; or (c) the use
or combination of Product
with other products where
the Product does not itself
infringe. As to the aboveidentified claim situations
where the preceding
paragraph does not apply,
Buyer shall defend and hold
Seller harmless in the same
manner and to the extent as
Seller’s obligations described
in the preceding paragraph.
Buyer shall be responsible for
obtaining (at Buyer’s
expense) all license rights
required for Seller to be able
to use software products in
the possession of Buyer
where such use is required in
order to perform any Service
for Buyer.
With respect to a Product or
part thereof not manufactured
by Seller or its subsidiaries,
Seller will attempt to obtain
for Buyer, from the supplier(s),
the patent indemnification
protection normally provided
by the supplier(s) to
customers.

Compliance with OSHA
Seller offers no warranty and
makes no representation that
its Products comply with the
provisions or standards of the
Occupational Safety and
Health Act of 1970, or any
regulation issued thereunder.
In no event shall Seller be
liable for any loss, damage,
fines, penalty or expenses
arising under said Act.
Limitation of Liability
THE REMEDIES OF THE
BUYER SET FORTH IN THIS
CONTRACT ARE EXCLUSIVE
AND ARE ITS SOLE
REMEDIES FOR ANY
FAILURE OF SELLER
TO COMPLY WITH ITS
OBLIGATIONS HEREUNDER.
NOTWITHSTANDING
ANY PROVISION IN THIS
CONTRACT TO THE
CONTRARY, IN NO EVENT
SHALL SELLER BE LIABLE
IN CONTRACT, IN TORT
(INCLUDING NEGLIGENCE
OR STRICT LIABILITY) OR
OTHERWISE FOR DAMAGE
TO PROPERTY OR
EQUIPMENT OTHER THAN
PRODUCTS SOLD
HEREUNDER, LOSS OF
PROFITS OR REVENUE,
LOSS OF USE OF
PRODUCTS, COST OF
CAPITAL, CLAIMS OF
CUSTOMERS OF THE
BUYER OR ANY SPECIAL,
INDIRECT, INCIDENTAL OR
CONSEQUENTIAL
DAMAGES WHATSOEVER,
REGARDLESS OF WHETHER
SUCH POTENTIAL
DAMAGES ARE
FORESEEABLE OR IF
SELLER HAS BEEN ADVISED
OF THE POSSIBILITY OF
SUCH DAMAGES.
THE TOTAL CUMULATIVE
LIABILITY OF SELLER
ARISING FROM OR
RELATED TO THIS
CONTRACT WHETHER
THE CLAIMS ARE BASED
IN CONTRACT, IN TORT
(INCLUDING NEGLIGENCE
OR STRICT LIABILITY) OR
OTHERWISE, SHALL NOT
EXCEED THE PRICE OF THE
PRODUCT OR SERVICES
ON WHICH SUCH LIABILITY
IS BASED.

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A1-5

Appendix 2—Superseded Style Number Index
Westinghouse 6 and 7 Digit Style Numbers
Westinghouse
6/7 Digit
Style Number

Eaton
10 Digit
Style Number

Voltage
Rating
kV Max.

Current
Rating
Amperes

Eaton Catalog Number

282429

25CLPT-.5E

677C452G04

CL fuse unit

282430

8CLPT-.5E

677C452G02

CL fuse unit

CLE-PT

25

0.5

CLE-PT

8.3

364228

Obsolete—contact Eaton

—

6 ft switch stick

0.5

—

—

—

364229

Obsolete—contact Eaton

—

562477

Obsolete—contact Eaton

677C593G01

10 ft switch stick

—

—

—

CL fuse unit

CLV

0.6

823252

15BA2-5E

2

117D123A18

Fuse refill unit

BA-200

15.5

825626

5

Obsolete—contact Eaton

304C437G01

Outdoor disconnect mounting

BA-200

8.3

200

825627

Obsolete—contact Eaton

304C437G02

Outdoor disconnect mounting

BA-200

15.5

200

825628

Obsolete—contact Eaton

—

Outdoor disconnect mounting

BA-200

25.5

200

825629

Obsolete—contact Eaton

423D769G05

Disconnect fuse holder

BA-200

8.3

200

825630

Obsolete—contact Eaton

423D769G06

Disconnect fuse holder

BA-200

15.5

200

825631

Obsolete—contact Eaton

423D769G07

Disconnect fuse holder

BA-200

25.5

200

825725

Obsolete—contact Eaton

—

Disconnect live parts

BA-200

—

200

834237

25BA2-200E

117D123A46

Fuse refill unit

BA-200

25.5

200

834238

8BA2-5E

117D123A02

Fuse refill unit

BA-200

8.3

5

834239

8BA2-10E

117D123A04

Fuse refill unit

BA-200

8.3

10

834240

8BA2-15E

117D123A05

Fuse refill unit

BA-200

8.3

15

834241

8BA2-20E

117D123A06

Fuse refill unit

BA-200

8.3

20

834242

8BA2-25E

117D123A07

Fuse refill unit

BA-200

8.3

25

834243

8BA2-30E

117D123A08

Fuse refill unit

BA-200

8.3

30

834244

8BA2-40E

117D123A09

Fuse refill unit

BA-200

8.3

40

834245

8BA2-50E

117D123A10

Fuse refill unit

BA-200

8.3

50

834246

8BA2-65E

117D123A11

Fuse refill unit

BA-200

8.3

65

834247

8BA2-80E

117D123A12

Fuse refill unit

BA-200

8.3

80

834248

8BA2-100E

117D123A13

Fuse refill unit

BA-200

8.3

100

834249

8BA2-125E

117D123A14

Fuse refill unit

BA-200

8.3

125

834250

8BA2-150E

117D123A15

Fuse refill unit

BA-200

8.3

150

834251

8BA2-200E

117D123A16

Fuse refill unit

BA-200

8.3

200

834252

15BA2-5E

117D123A18

Fuse refill unit

BA-201

15.5

5

834253

15BA2-10E

117D123A20

Fuse refill unit

BA-200

15.5

10

834254

15BA2-15E

117D123A21

Fuse refill unit

BA-200

15.5

15

834255

15BA2-20E

117D123A22

Fuse refill unit

BA-200

15.5

20

834256

15BA2-25E

117D123A23

Fuse refill unit

BA-200

15.5

25

834257

15BA2-30E

117D123A24

Fuse refill unit

BA-200

15.5

30

834258

15BA2-40E

117D123A25

Fuse refill unit

BA-200

15.5

40

834259

15BA2-50E

117D123A26

Fuse refill unit

BA-200

15.5

50

834260

15BA2-65E

117D123A27

Fuse refill unit

BA-200

15.5

65

834261

15BA2-80E

117D123A28

Fuse refill unit

BA-201

15.5

80

834262

15BA2-125E

117D123A29

Fuse refill unit

BA-202

15.5

100

834263

15BA2-125E

117D123A30

Fuse refill unit

BA-203

15.5

125

834264

15BA2-150E

117D123A31

Fuse refill unit

BA-204

15.5

150

834265

15BA2-200E

117D123A32

Fuse refill unit

BA-205

15.5

200

834266

25BA2-5E

117D123A34

Fuse refill unit

BA-201

25.5

5

834267

25BA2-10E

117D123A36

Fuse refill unit

BA-200

25.5

10

834268

25BA2-15E

117D123A37

Fuse refill unit

BA-200

25.5

15

834269

25BA2-20E

117D123A38

Fuse refill unit

BA-200

25.5

20

834270

25BA2-25E

117D123A39

Fuse refill unit

BA-200

25.5

25

834271

25BA2-30E

117D123A40

Fuse refill unit

BA-200

25.5

30

834272

25BA2-40E

117D123A41

Fuse refill unit

BA-200

25.5

40

834273

25BA2-50E

117D123A42

Fuse refill unit

BA-200

25.5

50

Description

Type

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-1

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

834274

25BA2-65E

117D123A43

834275

25BA2-80E

117D123A44

Fuse refill unit

BA-200

25.5

65

Fuse refill unit

BA-200

25.5

834276

25BA2-125E

80

117D123A45

Fuse refill unit

BA-200

25.5

834277

100

25BA2-125E

117D123A46

Fuse refill unit

BA-200

25.5

125

834278

25BA2-150E

117D123A47

Fuse refill unit

BA-200

25.5

150

841737

8BA2-.5E

117D123A01

Fuse refill unit

BA-200

8.3

0.5

841831

Obsolete—contact Eaton

—

Indoor non-disconnect mounting

BA-100

15.5

100

858999

15BA2-.5E

117D123A17

Fuse refill unit

BA-200

15.5

0.5

859000

25BA2-.5E

117D123A33

Fuse refill unit

BA-200

25.5

0.5

859003

Obsolete—contact Eaton

—

Indoor non-disconnect mounting

BA-100

8.3

100

859004

Obsolete—contact Eaton

—

Indoor non-disconnect mounting

BA-100

25.5

100

859198

Obsolete—contact Eaton

423D769G01

Disconnect fuse holder ECD

BA-200

8.3

200

859199

Obsolete—contact Eaton

423D769G02

Disconnect fuse holder ECD

BA-200

15.5

200

859200

Obsolete—contact Eaton

423D769G03

Disconnect fuse holder ECD

BA-200

25.5

200

895134

Obsolete—contact Eaton

423D769G04

Disconnect fuse holder ECD

BA-200

38

400

895307

Obsolete—contact Eaton

—

Disconnect fuse holder

BA-400

25.5

400

896681

Obsolete—contact Eaton

—

Disconnect fuse holder

BA-400

8.3

400

896682

Obsolete—contact Eaton

—

Disconnect fuse holder

BA-400

15.5

400

896727

Obsolete—contact Eaton

—

Disconnect fuse holder

BA-400

8.3

400

896728

Obsolete—contact Eaton

—

Disconnect fuse holder

BA-400

15.5

400

896729

Obsolete—contact Eaton

—

Disconnect fuse holder

BA-400

25.5

400

896730

Obsolete—contact Eaton

—

Disconnect fuse holder

BA-400

38

400

896735

Obsolete—contact Eaton

—

Disconnect live parts

BA-400

896793

8BA4-125E

116D977A14

Fuse refill unit

BA-400

8.3

125

896794

15BA4-125E

116D977A34

Fuse refill unit

BA-400

12.5

125

896795

25BA4-125E

116D977A54

Fuse refill unit

BA-400

25.5

125

896796

38BA4-125E

116D977A74

Fuse refill unit

BA-400

38

125

896804

8BA4-5E

116D977A02

Fuse refill unit

BA-400

8.3

5

896805

Obsolete—contact Eaton

—

Fuse refill unit

BA-400

8.3

8

896806

8BA4-10E

116D977A04

Fuse refill unit

BA-400

8.3

10

896807

8BA4-15E

116D977A05

Fuse refill unit

BA-400

8.3

15

896808

8BA4-20E

116D977A06

Fuse refill unit

BA-400

8.3

20

896809

8BA4-25E

116D977A07

Fuse refill unit

BA-400

8.3

25

896810

8BA4-30E

116D977A08

Fuse refill unit

BA-400

8.3

30

896811

8BA4-40E

116D977A09

Fuse refill unit

BA-400

8.3

40

896812

8BA4-50E

116D977A10

Fuse refill unit

BA-400

8.3

50

896813

8BA4-65E

116D977A11

Fuse refill unit

BA-400

8.3

62

896814

8BA4-80E

116D977A12

Fuse refill unit

BA-400

8.3

80

896815

8BA4-100E

116D977A13

Fuse refill unit

BA-400

8.3

100

896816

8BA4-150E

116D977A15

Fuse refill unit

BA-400

8.3

150

896817

8BA4-200E

116D977A16

Fuse refill unit

BA-400

8.3

200

896818

8BA4-250E

116D977A17

Fuse refill unit

BA-400

8.3

250

896819

8BA4-300E

116D977A18

Fuse refill unit

BA-400

8.3

300

896820

8BA4-400E

116D977A19

Fuse refill unit

BA-400

8.3

400

896821

15BA4-5E

116D977A22

Fuse refill unit

BA-400

15.5

5

896822

Obsolete—contact Eaton

—

Fuse refill unit

BA-400

15.5

8

896823

15BA4-10E

116D977A24

Fuse refill unit

BA-400

15.5

10

896824

15BA4-15E

116D977A25

Fuse refill unit

BA-400

15.5

15

896825

15BA4-20E

116D977A26

Fuse refill unit

BA-400

15.5

20

896826

15BA4-25E

116D977A27

Fuse refill unit

BA-400

15.5

25

896827

15BA4-30E

116D977A28

Fuse refill unit

BA-400

15.5

30

896828

15BA4-40E

116D977A29

Fuse refill unit

BA-400

15.5

40

896829

15BA4-50E

116D977A30

Fuse refill unit

BA-400

15.5

50

V14-A2-2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

400

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

896830

15BA4-65E

116D977A31

896831

15BA4-80E

116D977A32

Fuse refill unit

BA-400

15.5

62

Fuse refill unit

BA-400

15.5

896832

15BA4-100E

80

116D977A33

Fuse refill unit

BA-400

15.5

896833

100

15BA4-150E

116D977A35

Fuse refill unit

BA-400

15.5

150

896834

15BA4-200E

116D977A36

Fuse refill unit

BA-400

15.5

200

896835

15BA4-250E

116D977A37

Fuse refill unit

BA-400

15.5

250

896836

15BA4-300E

116D977A38

Fuse refill unit

BA-400

15.5

300

896837

15BA4-400E

116D977A39

Fuse refill unit

BA-400

15.5

400

896838

25BA4-5E

116D977A42

Fuse refill unit

BA-400

25.5

5

896839

Obsolete—contact Eaton

—

Fuse refill unit

BA-400

25.5

8

896840

25BA4-10E

116D977A44

Fuse refill unit

BA-400

25.5

10

896841

25BA4-15E

116D977A45

Fuse refill unit

BA-400

25.5

15

896842

25BA4-20E

116D977A46

Fuse refill unit

BA-400

25.5

20

896843

25BA4-25E

116D977A47

Fuse refill unit

BA-400

25.5

25

896844

25BA4-30E

116D977A48

Fuse refill unit

BA-400

25.5

30

896845

25BA4-40E

116D977A49

Fuse refill unit

BA-400

25.5

40

896846

25BA4-50E

116D977A50

Fuse refill unit

BA-400

25.5

50

896847

25BA4-65E

116D977A51

Fuse refill unit

BA-400

25.5

62

896848

25BA4-80E

116D977A52

Fuse refill unit

BA-400

25.5

80

896849

25BA4-100E

116D977A53

Fuse refill unit

BA-400

25.5

100

896850

25BA4-150E

116D977A55

Fuse refill unit

BA-400

25.5

150

896851

25BA4-200E

116D977A56

Fuse refill unit

BA-400

25.5

200

896852

25BA4-250E

116D977A57

Fuse refill unit

BA-400

25.5

250

896853

25BA4-300E

116D977A58

Fuse refill unit

BA-400

25.5

300

896854

Obsolete—contact Eaton

—

Fuse refill unit

BA-400

25.5

400

896855

38BA4-5E

116D977A62

Fuse refill unit

BA-400

38

5

896856

Obsolete—contact Eaton

—

Fuse refill unit

BA-400

38

8

896857

38BA4-10E

116D977A64

Fuse refill unit

BA-400

38

10

896858

38BA4-15E

116D977A65

Fuse refill unit

BA-400

38

15

896859

38BA4-20E

116D977A66

Fuse refill unit

BA-400

38

20

896860

38BA4-25E

116D977A67

Fuse refill unit

BA-400

38

25

896861

38BA4-30E

116D977A68

Fuse refill unit

BA-400

38

30

896862

38BA4-40E

116D977A69

Fuse refill unit

BA-400

38

40

896863

38BA4-50E

116D977A70

Fuse refill unit

BA-400

38

50

896864

38BA4-65E

116D977A71

Fuse refill unit

BA-400

38

62

896865

38BA4-80E

116D977A72

Fuse refill unit

BA-400

38

80

896866

38BA4-100E

116D977A73

Fuse refill unit

BA-400

38

100

896867

38BA4-150E

116D977A75

Fuse refill unit

BA-400

38

150

896868

38BA4-200E

116D977A76

Fuse refill unit

BA-400

38

200

896869

38BA4-250E

116D977A77

Fuse refill unit

BA-400

38

250

896870

38BA4-300E

116D977A78

Fuse refill unit

BA-400

38

300

896871

Obsolete—contact Eaton

—

Fuse refill unit

BA-400

38

400

918534

8BA2-5E

117D123A02

Fuse refill unit

BA-200

8.3

5

918535

Obsolete—contact Eaton

—

Fuse refill unit

BA-200

15.5

8

918536

Obsolete—contact Eaton

—

Fuse refill unit

BA-200

25.5

8

918537

8BA2-200E

117D123A16

Fuse refill unit

BA-200

8.3

200

918538

15RBA2-150E

117D123A31

Fuse refill unit

BA-200

15.5

150

918539

25RBA2-150E

117D123A47

Fuse refill unit

BA-200

25.5

150

938936

25RBA4-.5E

116D977A41

Fuse refill unit

BA-400

25.5

0.5

938937

38RBA4-.5E

116D977A61

Fuse refill unit

BA-400

38

0.5

940001

Obsolete—contact Eaton

—

Indoor disconnect mounting

BA-400

8.3

400

940002

Obsolete—contact Eaton

—

Indoor disconnect mounting

BA-400

15.5

400

940003

Obsolete—contact Eaton

—

Indoor disconnect mounting

BA-400

25.5

400

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-3

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

940004

Obsolete—contact Eaton

—

Indoor disconnect mounting

BA-200

8.3

200

940005

Obsolete—contact Eaton

—

Indoor disconnect mounting

BA-200

15.5

200

940006

Obsolete—contact Eaton

—

Indoor disconnect mounting

BA-200

25.5

200

940007

Obsolete—contact Eaton

—

Indoor non-disconnect fuse holder

BA-100

8.3

100

940008

Obsolete—contact Eaton

—

Indoor non-disconnect fuse holder

BA-100

15.5

100

940009

Obsolete—contact Eaton

—

Indoor non-disconnect fuse holder

BA-100

25.5

100

948932

Obsolete—contact Eaton

—

Indoor disconnect mounting

BA-400

38

400

948933

Obsolete—contact Eaton

—

Indoor non-disconnect live parts

BA-100

948934

8RBA4-.5E

116D977A01

Fuse refill unit

BA-400

8.3

0.5

948935

15RBA4-.5E

116D977A21

Fuse refill unit

BA-400

15.5

0.5

970699

Obsolete—contact Eaton

434D316A04

Time lag fuse refill unit

BA-200

8.3

15

970700

Obsolete—contact Eaton

434D316A04

Time lag fuse refill unit

BA-200

8.3

15

970701

Obsolete—contact Eaton

434D316A05

Time lag fuse refill unit

BA-200

8.3

20

970702

Obsolete—contact Eaton

434D316A06

Time lag fuse refill unit

BA-200

8.3

25

970703

Obsolete—contact Eaton

434D316A07

Time lag fuse refill unit

BA-200

8.3

30

970704

Obsolete—contact Eaton

434D316A08

Time lag fuse refill unit

BA-200

8.3

40

970705

Obsolete—contact Eaton

434D316A09

Time lag fuse refill unit

BA-200

8.3

50

970706

Obsolete—contact Eaton

434D316A10

Time lag fuse refill unit

BA-200

8.3

65

970707

Obsolete—contact Eaton

434D316A11

Time lag fuse refill unit

BA-200

8.3

80

970708

Obsolete—contact Eaton

434D316A12

Time lag fuse refill unit

BA-200

8.3

100

970713

Obsolete—contact Eaton

434D316A19

Time lag fuse refill unit

BA-200

15.5

15

970714

Obsolete—contact Eaton

434D316A19

Time lag fuse refill unit

BA-200

15.5

15

970715

Obsolete—contact Eaton

434D316A20

Time lag fuse refill unit

BA-200

15.5

20

970716

Obsolete—contact Eaton

434D316A21

Time lag fuse refill unit

BA-200

15.5

25

970717

Obsolete—contact Eaton

434D316A22

Time lag fuse refill unit

BA-200

15.5

30

970718

Obsolete—contact Eaton

434D316A23

Time lag fuse refill unit

BA-200

15.5

40

970719

Obsolete—contact Eaton

434D316A24

Time lag fuse refill unit

BA-200

15.5

50

970720

Obsolete—contact Eaton

434D316A25

Time lag fuse refill unit

BA-200

15.5

65

970721

Obsolete—contact Eaton

434D316A26

Time lag fuse refill unit

BA-200

15.5

80

970722

Obsolete—contact Eaton

434D316A27

Time lag fuse refill unit

BA-200

15.5

100

907027

Obsolete—contact Eaton

434D316A34

Time lag fuse refill unit

BA-200

25.5

15

907028

Obsolete—contact Eaton

434D316A34

Time lag fuse refill unit

BA-200

25.5

15

907029

Obsolete—contact Eaton

434D316A35

Time lag fuse refill unit

BA-200

25.5

20

907030

Obsolete—contact Eaton

434D316A36

Time lag fuse refill unit

BA-200

25.5

25

907031

Obsolete—contact Eaton

434D316A37

Time lag fuse refill unit

BA-200

25.5

30

907032

Obsolete—contact Eaton

434D316A38

Time lag fuse refill unit

BA-200

25.5

40

907033

Obsolete—contact Eaton

434D316A39

Time lag fuse refill unit

BA-200

25.5

50

907034

Obsolete—contact Eaton

434D316A40

Time lag fuse refill unit

BA-200

25.5

65

907035

Obsolete—contact Eaton

434D316A41

Time lag fuse refill unit

BA-200

25.5

80

907036

Obsolete—contact Eaton

434D316A42

Time lag fuse refill unit

BA-200

25.5

100

1014184

Obsolete—contact Eaton

434D316A36

Time lag fuse refill unit

BA-200

25.5

25

1014190

Obsolete—contact Eaton

434D316A28

Time lag fuse refill unit

BA-200

15.5

125

1014191

Obsolete—contact Eaton

434D316A43

Time lag fuse refill unit

BA-200

25.5

125

1014286

RBA4-COND

310C197G04

Condenser (3 pack)

BA-400/RBA400

—

—

1043291

Obsolete—contact Eaton

423D769G08

Outdoor fuse holder 75

BA-200

38

200

1043297

38BA2-5E

117D123A50

Fuse refill unit

BA-200

38

5

1043298

38BA2-5E

117D123A50

Fuse refill unit

BA-200

38

5

1043299

38BA2-7E

117D123A51

Fuse refill unit

BA-200

38

7

1043300

38BA2-10E

117D123A52

Fuse refill unit

BA-200

38

10

1043301

38BA2-15E

117D123A53

Fuse refill unit

BA-200

38

15

1043302

38BA2-15E

117D123A53

Fuse refill unit

BA-200

38

15

1043303

38BA2-20E

117D123A54

Fuse refill unit

BA-200

38

20

1043304

38BA2-25E

117D123A55

Fuse refill unit

BA-200

38

25

V14-A2-4

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current
Rating
Amperes

100

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1043305

38BA2-30E

117D123A56

1043306

38BA2-40E

117D123A57

Fuse refill unit

BA-200

38

30

Fuse refill unit

BA-200

38

1043307

38BA2-50E

40

117D123A58

Fuse refill unit

BA-200

38

1043308

50

38BA2-65E

117D123A59

Fuse refill unit

BA-200

38

65

1043309

38BA2-80E

117D123A60

Fuse refill unit

BA-200

38

80

1043310

38BA2-100E

117D123A61

Fuse refill unit

BA-200

38

100

1043311

38BA2-125E

117D123A62

Fuse refill unit

BA-200

38

125

1043312

38BA2-150E

117D123A63

Fuse refill unit

BA-200

38

150

1043331

38BA2-.5E

117D123A49

Fuse refill unit

BA-200

38

0.5

1043673

Obsolete—contact Eaton

—

Outdoor fuse holder ECD 50

BA-200

25.5

200

1043678

Obsolete—contact Eaton

434D316A49

Time lag fuse refill unit

BA-200

38

15

1043679

Obsolete—contact Eaton

434D316A49

Time lag fuse refill unit

BA-200

38

15

1043680

Obsolete—contact Eaton

434D316A50

Time lag fuse refill unit

BA-200

38

20

1043681

Obsolete—contact Eaton

434D316A51

Time lag fuse refill unit

BA-200

38

25

1043682

Obsolete—contact Eaton

434D316A52

Time lag fuse refill unit

BA-200

38

30

1043683

Obsolete—contact Eaton

434D316A53

Time lag fuse refill unit

BA-200

38

40

1043684

Obsolete—contact Eaton

434D316A54

Time lag fuse refill unit

BA-200

38

50

1043685

Obsolete—contact Eaton

434D316A55

Time lag fuse refill unit

BA-200

38

65

1043686

Obsolete—contact Eaton

434D316A56

Time lag fuse refill unit

BA-200

38

80

1043687

Obsolete—contact Eaton

434D316A57

Time lag fuse refill unit

BA-200

38

100

1043688

Obsolete—contact Eaton

434D316A58

Time lag fuse refill unit

BA-200

38

125

1043691

Obsolete—contact Eaton

423D769G04

Outdoor fuse holder ECD 50

BA-400

38

400

1043720

8BA4-300E

116D977A18

Fuse refill unit

BA-400

8.3

300

1081323

2NCLPT-.5E

677C592G02

CL fuse unit

NCLE-PT

2.75

0.5

1105207

Obsolete—contact Eaton

423D769G12

Outdoor fuse holder ECD 180

BA-400

38

200

1105208

Obsolete—contact Eaton

505D616A01

Live parts

BA-200

—

—

1105209

Obsolete—contact Eaton

505D615A01

Live parts

BA-400

—

—

1123938

Obsolete—contact Eaton

423D770G08

Outdoor fuse holder

BA-400

38

300

1196126

8CLPT-.5E

677C452G02

CL fuse unit

CLE-PT

8.3

0.5

1196127

15CLPT-.5E

677C452G03

CL fuse unit

CLE-PT

15.5

0.5

1196127D

2NCLPT-1E

677C592G03

CL fuse unit

NCLE-PT

2.75

1

1169143

2NCLPT-.5E

677C592G02

CL fuse unit

NCLE-PT

2.75

0.5

1247212

2NCLPT-1E

677C592G03

CL fuse unit

NCLE-PT

2.75

1

1247217

5CLPT-.5E

677C452G01

CL fuse unit

CLE-PT

5.5

0.5

1247218

8CLPT-.5E

677C452G02

CL fuse unit

CLE-PT

8.3

0.5

1247219

15CLPT-.5E

677C452G03

CL fuse unit

CLE-PT

15.5

0.5

1247220

25CLPT-.5E

677C452G04

CL fuse unit

CLE-PT

25.5

0.5

1251000

8DBA1-0.5

5980C15G01

—

—

—

—

1251000

8DBA1-3E

505D420G01

—

—

—

—

1251002

8DBA1-5E

5980C15G03

—

—

—

—

1251003

8DBA1-7E

5980C15G04

—

—

—

—

1251004

8DBA1-10E

5980C15G05

—

—

—

—

1251005

8DBA1-15E

5980C15G06

—

—

—

—

1251006

8DBA1-20E

5980C15G07

—

—

—

—

1251007

8DBA1-25E

5980C15G08

—

—

—

—

1251008

8DBA1-30E

5980C15G09

—

—

—

—

1251009

8DBA1-40E

5980C15G10

—

—

—

—

1251010

8DBA1-50E

5980C15G11

—

—

—

—

1251011

8DBA1-65E

5980C15G12

—

—

—

—

1251012

8DBA1-80E

5980C15G13

—

—

—

—

1251013

8DBA1-100E

5980C15G14

—

—

—

—

1251014

8DBA1-125E

5980C15G15

—

—

—

—

1251015

8DBA1-150E

5980C15G16

—

—

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-5

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

1251016

8DBA1-200E

5980C15G17

—

—

—

—

1251017

15DBA1-0.5

5980C15G21

—

—

—

—

1251018

15DBA1-3E

505D420G02

—

—

—

—

1251019

15DBA1-5E

5980C15G23

—

—

—

—

1251020

15DBA1-7E

5980C15G24

—

—

—

—

1251021

15DBA1-10E

5980C15G25

—

—

—

—

1251022

15DBA1-15E

5980C15G26

—

—

—

—

1251023

15DBA1-20E

5980C15G27

—

—

—

—

1251024

15DBA1-25E

5980C15G28

—

—

—

—

1251025

15DBA1-30E

5980C15G29

—

—

—

—

1251026

15DBA1-40E

5980C15G30

—

—

—

—

1251027

15DBA1-50E

5980C15G31

—

—

—

—

1251028

15DBA1-65E

5980C15G32

—

—

—

—

1251029

15DBA1-80E

5980C15G33

—

—

—

—

1251030

15DBA1-100E

5980C15G34

—

—

—

—

1251031

15DBA1-125E

5980C15G35

—

—

—

—

1251032

15DBA1-150E

5980C15G36

—

—

—

—

1251033

15DBA1-200E

5980C15G37

—

—

—

—

1251034

25DBA1-0.5

5980C16G01

—

—

—

—

1251035

25DBA1-3E

505D420G03

—

—

—

—

1251036

25DBA1-5E

5980C16G03

—

—

—

—

1251037

25DBA1-7E

5980C16G04

—

—

—

—

1251038

25DBA1-10E

5980C16G05

—

—

—

—

1251039

25DBA1-15E

5980C16G06

—

—

—

—

1251040

25DBA1-20E

5980C16G07

—

—

—

—

1251041

25DBA1-25E

5980C16G08

—

—

—

—

1251042

25DBA1-30E

5980C16G09

—

—

—

—

1251043

25DBA1-40E

5980C16G10

—

—

—

—

1251044

25DBA1-50E

5980C16G11

—

—

—

—

1251045

25DBA1-65E

5980C16G12

—

—

—

—

1251046

25DBA1-80E

5980C16G13

—

—

—

—

1251047

25DBA1-100E

5980C16G14

—

—

—

—

1251048

25DBA1-125E

5980C16G15

—

—

—

—

1251049

25DBA1-150E

5980C16G16

—

—

—

—

1251050

25DBA1-200E

5980C16G17

—

—

—

—

1251051

38DBA1-0.5

5980C16G21

—

—

—

—

1251052

38DBA1-3E

505D420G04

—

—

—

—

1251053

38DBA1-5E

5980C16G23

—

—

—

—

1251054

38DBA1-7E

5980C16G24

—

—

—

—

1251055

38DBA1-10E

5980C16G25

—

—

—

—

1251056

38DBA1-15E

5980C16G26

—

—

—

—

1251057

38DBA1-20E

5980C16G27

—

—

—

—

1251058

38DBA1-25E

5980C16G28

—

—

—

—

1251059

38DBA1-30E

5980C16G29

—

—

—

—

1251060

38DBA1-40E

5980C16G30

—

—

—

—

1251061

38DBA1-50E

5980C16G31

—

—

—

—

1251062

38DBA1-65E

5980C16G32

—

—

—

—

1251063

38DBA1-80E

5980C16G33

—

—

—

—

1251064

38DBA1-100E

5980C16G34

—

—

—

—

1251065

38DBA1-125E

5980C16G35

—

—

—

—

1251066

38DBA1-150E

5980C16G36

—

—

—

—

1251067

38DBA1-200E

5980C16G37

—

—

—

—

1251068

48DBA1-0.5

5980C17G01

—

—

—

—

V14-A2-6

Eaton
10 Digit
Style Number

Description

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1251069

48DBA1-3E

505D420G05

1251070

48DBA1-5E

5980C17G03

—

—

—

—

—

—

—

1251071

48DBA1-7E

—

5980C17G04

—

—

—

1251072

—

48DBA1-10E

5980C17G05

—

—

—

—

1251073

48DBA1-15E

5980C17G06

—

—

—

—

1251074

48DBA1-20E

5980C17G07

—

—

—

—

1251075

48DBA1-25E

5980C17G08

—

—

—

—

1251076

48DBA1-30E

5980C17G09

—

—

—

—

1251077

48DBA1-40E

5980C17G10

—

—

—

—

1251078

48DBA1-50E

5980C17G11

—

—

—

—

1251079

48DBA1-65E

5980C17G12

—

—

—

—

1251080

48DBA1-80E

5980C17G13

—

—

—

—

1251081

48DBA1-100E

5980C17G14

—

—

—

—

1251082

48DBA1-125E

5980C17G15

—

—

—

—

1251083

48DBA1-150E

5980C17G16

—

—

—

—

1251084

48DBA1-200E

5980C17G17

—

—

—

—

1251085

72DBA1-0.5

5980C17G21

—

—

—

—

1251086

72DBA1-3E

505D420G06

—

—

—

—

1251087

72DBA1-5E

5980C17G23

—

—

—

—

1251088

72DBA1-7E

5980C17G24

—

—

—

—

1251089

72DBA1-10E

5980C17G25

—

—

—

—

1251090

72DBA1-15E

5980C17G26

—

—

—

—

1251091

72DBA1-20E

5980C17G27

—

—

—

—

1251092

72DBA1-25E

5980C17G28

—

—

—

—

1251093

72DBA1-30E

5980C17G29

—

—

—

—

1251094

72DBA1-40E

5980C17G30

—

—

—

—

1251095

72DBA1-50E

5980C17G31

—

—

—

—

1251096

72DBA1-65E

5980C17G32

—

—

—

—

1251097

72DBA1-80E

5980C17G33

—

—

—

—

1251098

72DBA1-100E

5980C17G34

—

—

—

—

1251099

72DBA1-125E

5980C17G35

—

—

—

—

1251100

72DBA1-150E

5980C17G36

—

—

—

—

1251101

72DBA1-200E

5980C17G37

—

—

—

—

1251138

2NCLPT-1E

677C592G03

CL fuse unit

NCLE-PT

2.75

1

1254953

Obsolete—contact Eaton

677C593G01

CL fuse unit

CLV

0.6

2

1253955

Obsolete—contact Eaton

677C593G02

CL fuse unit

CLV

0.6

5

1257527

Obsolete—contact Eaton

—

Live parts

DBA-2

1257601

72DBA2-3E

11A8127G02

—

—

—

—

1257603

72DBA2-7E

11A8127G03

—

—

—

—

1257604

72DBA2-10E

11A8127G04

—

—

—

—

1257605

72DBA2-15E

11A8127G05

—

—

—

—

1257606

72DBA2-20E

11A8127G06

—

—

—

—

1257607

72DBA2-25E

11A8127G07

—

—

—

—

1257608

72DBA2-30E

11A8127G08

—

—

—

—

1257609

72DBA2-40E

11A8127G09

—

—

—

—

1257610

72DBA2-50E

11A8127G10

—

—

—

—

1257611

72DBA2-65E

11A8127G11

—

—

—

—

1257612

72DBA2-80E

11A8127G12

—

—

—

—

1257613

72DBA2-100E

11A8127G13

—

—

—

—

1257614

72DBA2-125E

11A8127G14

—

—

—

—

1257615

72DBA2-150E

11A8127G15

—

—

—

—

1257617

92DBA2-3E

11A8127G21

—

—

—

—

1257618

92DBA2-5E

11A8127G22

—

—

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-7

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1257619

92DBA2-7E

11A8127G23

1257620

92DBA2-10E

11A8127G24

—

—

—

—

—

—

—

1257621

92DBA2-15E

—

11A8127G25

—

—

—

1257622

—

92DBA2-20E

11A8127G26

—

—

—

—

1257623

92DBA2-25E

11A8127G27

—

—

—

—

1257624

92DBA2-30E

11A8127G28

—

—

—

—

1257625

92DBA2-40E

11A8127G29

—

—

—

—

1257626

92DBA2-50E

11A8127G30

—

—

—

—

1257627

92DBA2-65E

11A8127G31

—

—

—

—

1257628

92DBA2-80E

11A8127G32

—

—

—

—

1257629

92DBA2-100E

11A8127G33

—

—

—

—

1257630

92DBA2-125E

11A8127G34

—

—

—

—

1257631

92DBA2-150E

11A8127G35

—

—

—

—

1257633

121DBA2-3E

11A8127G41

—

—

—

—

1257634

121DBA2-5E

11A8127G42

—

—

—

—

1257635

121DBA2-7E

11A8127G43

—

—

—

—

1257636

121DBA2-10E

11A8127G44

—

—

—

—

1257637

121DBA2-15E

11A8127G45

—

—

—

—

1257638

121DBA2-20E

11A8127G46

—

—

—

—

1257639

121DBA2-25E

11A8127G47

—

—

—

—

1257640

121DBA2-30E

11A8127G48

—

—

—

—

1257641

121DBA2-40E

11A8127G49

—

—

—

—

1257642

121DBA2-50E

11A8127G50

—

—

—

—

1257641

121DBA2-65E

11A8127G51

—

—

—

—

1257642

121DBA2-80E

11A8127G52

—

—

—

—

1257643

121DBA2-100E

11A8127G53

—

—

—

—

1257644

121DBA2-125E

11A8127G54

—

—

—

—

1257645

121DBA2-150E

11A8127G55

—

—

—

—

1285491

5CLPT-1E

677C452G06

CL fuse unit

CLE-PT

5.5

1

1291963

5CLPT-5E

677C453G01

CL fuse unit

CLE-PT

5.5

5

1291964

8CLPT-5E

677C453G02

CL fuse unit

CLE-PT

8.3

5

1291965

15CLPT-5E

677C453G03

CL fuse unit

CLE-PT

15.5

5

1291968

5CLPT-10E

677C453G04

CL fuse unit

CLE-PT

5.5

10

1291969

8CLPT-10E

677C453G05

CL fuse unit

CLE-PT

8.3

10

1291970

15CLPT-10E

677C453G06

CL fuse unit

CLE-PT

15.5

10

1301110

RBA2-COND

310C197G03

Condenser (3 pack)

BA-200/RBA-200

—

—

1305001

Obsolete—contact Eaton

—

Non-disconnect mounting

BA-100

5.5

100

1305002

Obsolete—contact Eaton

—

Non-disconnect mounting

BA-100

8.3

100

1305003

Obsolete—contact Eaton

—

Non-disconnect mounting

BA-100

14.4

100

1305004

Obsolete—contact Eaton

—

Non-disconnect mounting

BA-100

15.5

100

1305005

Obsolete—contact Eaton

—

Non-disconnect mounting

BA-100

25.5

100

1305006

Obsolete—contact Eaton

—

Non-disconnect mounting

BA-200

38

200

1305020

Obsolete—contact Eaton

414D224G01

Disconnect mounting

BA-200

5.5

200

1305021

Obsolete—contact Eaton

414D224G02

Disconnect mounting

BA-200

8.3

200

1305022

Obsolete—contact Eaton

414D224G03

Disconnect mounting

BA-100

14.4

100

1305023

Obsolete—contact Eaton

414D224G04

Disconnect mounting

BA-100

15.5

100

1305024

Obsolete—contact Eaton

414D224G05

Disconnect mounting

BA-200

25.5

—

1305025

Obsolete—contact Eaton

414D224G07

Mounting

BA-200

5.5

—

1305026

Obsolete—contact Eaton

414D224G08

Mounting

BA-200

8.3

—

1305027

Obsolete—contact Eaton

414D224G09

Mounting

BA-200

14.5

—

1305028

Obsolete—contact Eaton

414D224G10

Mounting

BA-200

15.5

—

1305030

Obsolete—contact Eaton

414D224G11

Mounting

BA-200

5.5

—

1305031

Obsolete—contact Eaton

414D224G12

Mounting

BA-200

8.3

—

V14-A2-8

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1305032

Obsolete—contact Eaton

414D224G13

1305033

Obsolete—contact Eaton

414D224G14

Mounting

BA-200

14.5

—

Mounting

BA-200

15.5

1305035

Obsolete—contact Eaton

—

414D224G15

Disconnect mounting RC

BA-200

5.5

—

1305036
1305037

Obsolete—contact Eaton

414D224G16

Disconnect mounting RC

BA-200

8.3

—

Obsolete—contact Eaton

414D224G17

Disconnect mounting RC

BA-200

14.5

—

1305038

Obsolete—contact Eaton

414D224G18

Disconnect mounting RC

BA-200

15.5

—

1305040

Obsolete—contact Eaton

414D226G01

Disconnect mounting

BA-400

5.5

—

1305041

Obsolete—contact Eaton

414D226G02

Disconnect mounting

BA-400

8.3

—

1305042

Obsolete—contact Eaton

414D226G03

Disconnect mounting

BA-400

14.5

—

1305043

Obsolete—contact Eaton

414D226G04

Disconnect mounting

BA-400

15.5

—

1305044

Obsolete—contact Eaton

414D226G05

Disconnect mounting

BA-400

25.5

—

1305045

Obsolete—contact Eaton

414D226G07

Mounting

BA-400

5.5

—

1305046

Obsolete—contact Eaton

414D226G08

Mounting

BA-400

8.3

—

1305047

Obsolete—contact Eaton

414D226G09

Mounting

BA-400

14.5

—

1305048

Obsolete—contact Eaton

414D226G10

Mounting

BA-400

15.5

—

1305049

Obsolete—contact Eaton

414D226G11

Mounting

BA-400

15.5

—

1305050

Obsolete—contact Eaton

414D226G12

Mounting

BA-400

5.5

—

1305051

Obsolete—contact Eaton

414D226G13

Mounting

BA-400

8.3

—

1305052

Obsolete—contact Eaton

414D226G14

Mounting

BA-400

14.5

—

1305053

Obsolete—contact Eaton

414D226G15

Mounting

BA-400

15.5

—

1305054

Obsolete—contact Eaton

414D226G16

Mounting

BA-400

25.5

—

1305055

Obsolete—contact Eaton

414D226G17

Disconnect mounting RC

BA-400

5.5

—

1305056

Obsolete—contact Eaton

414D226G18

Disconnect mounting RC

BA-400

8.3

—

1305057

Obsolete—contact Eaton

414D226G19

Disconnect mounting RC

BA-400

14.5

—

1305058

Obsolete—contact Eaton

414D226G20

Disconnect mounting RC

BA-400

15.5

—

1305059

Obsolete—contact Eaton

414D226G21

Mounting

BA-400

25.5

—

1305060

Obsolete—contact Eaton

414D225G01

Disconnect mounting FCV

BA-200

5.5

—

1305061

Obsolete—contact Eaton

414D225G02

Disconnect mounting FCV

BA-200

8.3

—

1305062

Obsolete—contact Eaton

414D225G03

Disconnect mounting FCV

BA-200

14.5

—

1305063

Obsolete—contact Eaton

414D225G04

Disconnect mounting FCV

BA-200

15.5

—

1305064

Obsolete—contact Eaton

414D225G05

Disconnect mounting FCV

BA-200

25.5

—

1305065

Obsolete—contact Eaton

414D225G07

Mounting

BA-200

5.5

—

1305066

Obsolete—contact Eaton

414D225G08

Mounting

BA-200

8.3

—

1305067

Obsolete—contact Eaton

414D225G09

Mounting

BA-200

14.5

—

1305068

Obsolete—contact Eaton

414D225G10

Mounting

BA-200

15.5

—

1305070

Obsolete—contact Eaton

414D225G11

Mounting

BA-200

5.5

—

1305071

Obsolete—contact Eaton

414D225G12

Mounting

BA-200

8.3

—

1305072

Obsolete—contact Eaton

414D225G13

Mounting

BA-200

14.5

—

1305073

Obsolete—contact Eaton

414D225G14

Mounting

BA-200

15.5

—

1305075

Obsolete—contact Eaton

414D225G15

Disconnect mounting RCV

BA-200

5.5

—

1305076

Obsolete—contact Eaton

414D225G16

Disconnect mounting RCV

BA-200

8.3

—

1305077

Obsolete—contact Eaton

414D225G17

Disconnect mounting RCV

BA-200

14.5

—

1305078

Obsolete—contact Eaton

414D225G18

Disconnect mounting RCV

BA-200

15.5

—

1305080

Obsolete—contact Eaton

414D227G01

Disconnect mounting FCV

BA-400

5.5

—

1305081

Obsolete—contact Eaton

414D227G02

Disconnect mounting FCV

BA-400

8.3

—

1305082

Obsolete—contact Eaton

414D227G03

Disconnect mounting FCV

BA-400

14.5

—

1305083

Obsolete—contact Eaton

414D227G04

Disconnect mounting FCV

BA-400

15.5

—

1305084

Obsolete—contact Eaton

414D227G05

Disconnect mounting FCV

BA-400

25.5

—

1305085

Obsolete—contact Eaton

414D227G07

Mounting

BA-400

5.5

—

1305086

Obsolete—contact Eaton

414D227G08

Mounting

BA-400

8.3

—

1305087

Obsolete—contact Eaton

414D227G09

Mounting

BA-400

14.5

—

1305088

Obsolete—contact Eaton

414D227G10

Mounting

BA-400

15.5

—

1305089

Obsolete—contact Eaton

414D227G11

Mounting

BA-400

25.5

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-9

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1305090

Obsolete—contact Eaton

414D227G12

1305091

Obsolete—contact Eaton

414D227G13

Mounting

BA-400

5.5

—

Mounting

BA-400

8.3

1305092

Obsolete—contact Eaton

—

414D227G14

Mounting

BA-400

14.5

—

1305093
1305094

Obsolete—contact Eaton

414D227G15

Mounting

BA-400

15.5

—

Obsolete—contact Eaton

414D227G16

Mounting

BA-400

25.5

—

1305095

Obsolete—contact Eaton

414D227G17

Disconnect mounting RCV

BA-400

5.5

—

1305096

Obsolete—contact Eaton

414D227G18

Disconnect mounting RCV

BA-400

8.3

—

1305097

Obsolete—contact Eaton

414D227G19

Disconnect mounting RCV

BA-400

14.5

—

1305098

Obsolete—contact Eaton

414D227G20

Disconnect mounting RCV

BA-400

15.5

—

1305099

Obsolete—contact Eaton

414D227G21

Mounting

BA-400

25.5

—

1305318

Obsolete—contact Eaton

304C437G01

Mounting

BA-200

8.3

—

1305319

Obsolete—contact Eaton

304C437G02

Mounting

BA-200

15.5

—

1305320

Obsolete—contact Eaton

304C437G03

Mounting

BA-200

25.5

—

1305321

Obsolete—contact Eaton

304C437G04

Mounting

BA-200

38

—

1305326

Obsolete—contact Eaton

304C444G01

Disconnect mounting ECD

BA-400

8.3

—

1305327

Obsolete—contact Eaton

304C444G02

Disconnect mounting ECD

BA-400

15.5

—

1305328

Obsolete—contact Eaton

304C444G03

Disconnect mounting ECD

BA-400

25.5

—

1305329

Obsolete—contact Eaton

304C444G04

Disconnect mounting ECD

BA-400

38

—

1305334

Obsolete—contact Eaton

304C438G01

Disconnect mounting ECD

BA-200

8.3

—

1305335

Obsolete—contact Eaton

304C438G02

Disconnect mounting ECD

BA-200

15.5

—

1305336

Obsolete—contact Eaton

304C438G03

Disconnect mounting ECD

BA-200

25.5

—

1305337

Obsolete—contact Eaton

304C438G04

Disconnect mounting ECD

BA-200

38

—

1305432

Obsolete—contact Eaton

432D140A02

Mounting

BAL

5.5

—

1305437

Obsolete—contact Eaton

432D140A32

Mounting

BAL

2.75

—

1305438

Obsolete—contact Eaton

432D140A33

Mounting

BAL

5.5

—

1305445

72DBA2-200E

11A8127G16

—

—

—

—

1305445

92DBA2-200E

11A8127G36

—

—

—

—

1305445

121DBA2-200E

11A8127G56

—

—

—

—

1310755

Obsolete—contact Eaton

—

Mounting

BAL-100

25.5

—

1310996

Obsolete—contact Eaton

310C197G04

Condenser (outdoor)

BA-400

—

—

1310997

Obsolete—contact Eaton

310C197G03

Condenser (outdoor)

BA-200

—

—

1314000

8BA2-.5E

117D123A01

Fuse refill unit

BA-200

8.3

0.5

1314001

8BA2-5E

117D123A02

Fuse refill unit

BA-200

8.3

5

1314002

8BA2-7E

117D123A03

Fuse refill unit

BA-200

8.3

7

1314003

8BA2-10E

117D123A04

Fuse refill unit

BA-200

8.3

10

1314004

8BA2-15E

117D123A05

Fuse refill unit

BA-200

8.3

15

1314005

8BA2-20E

117D123A06

Fuse refill unit

BA-200

8.3

20

1314006

8BA2-25E

117D123A07

Fuse refill unit

BA-200

8.3

25

1314007

8BA2-30E

117D123A08

Fuse refill unit

BA-200

8.3

30

1314008

8BA2-40E

117D123A09

Fuse refill unit

BA-200

8.3

40

1314009

8BA2-50E

117D123A10

Fuse refill unit

BA-200

8.3

50

1314010

8BA2-65E

117D123A11

Fuse refill unit

BA-200

8.3

654

1314011

8BA2-80E

117D123A12

Fuse refill unit

BA-200

8.3

80

1314012

8BA2-100E

117D123A13

Fuse refill unit

BA-200

8.3

100

1314013

8BA2-125E

117D123A14

Fuse refill unit

BA-200

8.3

125

1314014

8BA2-150E

117D123A15

Fuse refill unit

BA-200

8.3

150

1314015

8BA2-200E

117D123A16

Fuse refill unit

BA-200

8.3

200

1314016

15BA2-.5E

117D123A01

Fuse refill unit

BA-200

15.5

0.5

1314017

15BA2-5E

117D123A02

Fuse refill unit

BA-200

15.5

5

1314018

15BA2-7E

117D123A03

Fuse refill unit

BA-200

15.5

7

1314019

15BA2-10E

117D123A04

Fuse refill unit

BA-200

15.5

10

1314020

15BA2-15E

117D123A05

Fuse refill unit

BA-200

15.5

15

1314021

15BA2-20E

117D123A06

Fuse refill unit

BA-200

15.5

20

V14-A2-10

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1314022

15BA2-25E

117D123A07

1314023

15BA2-30E

117D123A08

Fuse refill unit

BA-200

15.5

25

Fuse refill unit

BA-200

15.5

1314024

15BA2-40E

30

117D123A09

Fuse refill unit

BA-200

15.5

1314025

40

15BA2-50E

117D123A10

Fuse refill unit

BA-200

15.5

50

1314026

15BA2-65E

117D123A11

Fuse refill unit

BA-200

15.5

654

1314027

15BA2-80E

117D123A12

Fuse refill unit

BA-200

15.5

80

1314028

15BA2-100E

117D123A13

Fuse refill unit

BA-200

15.5

100

1314029

15BA2-125E

117D123A14

Fuse refill unit

BA-200

15.5

125

1314030

15BA2-150E

117D123A15

Fuse refill unit

BA-200

15.5

150

1314031

15BA2-200E

117D123A16

Fuse refill unit

BA-200

15.5

200

1314032

25BA2-.5E

117D123A01

Fuse refill unit

BA-200

25.5

0.5

1314033

25BA2-5E

117D123A02

Fuse refill unit

BA-200

25.5

5

1314034

25BA2-7E

117D123A03

Fuse refill unit

BA-200

25.5

7

1314035

25BA2-10E

117D123A04

Fuse refill unit

BA-200

25.5

10

1314036

25BA2-15E

117D123A05

Fuse refill unit

BA-200

25.5

15

1314037

25BA2-20E

117D123A06

Fuse refill unit

BA-200

25.5

20

1314038

25BA2-25E

117D123A07

Fuse refill unit

BA-200

25.5

25

1314039

25BA2-30E

117D123A08

Fuse refill unit

BA-200

25.5

30

1314040

25BA2-40E

117D123A09

Fuse refill unit

BA-200

25.5

40

1314041

25BA2-50E

117D123A10

Fuse refill unit

BA-200

25.5

50

1314042

25BA2-65E

117D123A11

Fuse refill unit

BA-200

25.5

654

1314043

25BA2-80E

117D123A12

Fuse refill unit

BA-200

25.5

80

1314044

25BA2-100E

117D123A13

Fuse refill unit

BA-200

25.5

100

1314045

25BA2-125E

117D123A14

Fuse refill unit

BA-200

25.5

125

1314046

25BA2-150E

117D123A15

Fuse refill unit

BA-200

25.5

150

1314047

25BA2-200E

117D123A16

Fuse refill unit

BA-200

25.5

200

1314048

38BA2-.5E

117D123A01

Fuse refill unit

BA-200

38

0.5

1314049

38BA2-5E

117D123A02

Fuse refill unit

BA-200

38

5

1314050

38BA2-7E

117D123A03

Fuse refill unit

BA-200

38

7

1314051

38BA2-10E

117D123A04

Fuse refill unit

BA-200

38

10

1314052

38BA2-15E

117D123A05

Fuse refill unit

BA-200

38

15

1314053

38BA2-20E

117D123A06

Fuse refill unit

BA-200

38

20

1314054

38BA2-25E

117D123A07

Fuse refill unit

BA-200

38

25

1314055

38BA2-30E

117D123A08

Fuse refill unit

BA-200

38

30

1314056

38BA2-40E

117D123A09

Fuse refill unit

BA-200

38

40

1314057

38BA2-50E

117D123A10

Fuse refill unit

BA-200

38

50

1314058

38BA2-65E

117D123A11

Fuse refill unit

BA-200

38

654

1314059

38BA2-80E

117D123A12

Fuse refill unit

BA-200

38

80

1314060

38BA2-100E

117D123A13

Fuse refill unit

BA-200

38

100

1314061

38BA2-125E

117D123A14

Fuse refill unit

BA-200

38

125

1314062

38BA2-150E

117D123A15

Fuse refill unit

BA-200

38

150

1314063

38BA2-200E

117D123A16

Fuse refill unit

BA-200

38

200

1314067

Obsolete—contact Eaton

434D316A04

Time lag fuse refill unit

BA-200

8.3

15

1314068

Obsolete—contact Eaton

434D316A05

Time lag fuse refill unit

BA-200

8.3

20

1314069

Obsolete—contact Eaton

434D316A06

Time lag fuse refill unit

BA-200

8.3

25

1314070

Obsolete—contact Eaton

434D316A07

Time lag fuse refill unit

BA-200

8.3

30

1314071

Obsolete—contact Eaton

434D316A08

Time lag fuse refill unit

BA-200

8.3

40

1314072

Obsolete—contact Eaton

434D316A09

Time lag fuse refill unit

BA-200

8.3

50

1314073

Obsolete—contact Eaton

434D316A10

Time lag fuse refill unit

BA-200

8.3

654

1314074

Obsolete—contact Eaton

434D316A11

Time lag fuse refill unit

BA-200

8.3

80

1314075

Obsolete—contact Eaton

434D316A12

Time lag fuse refill unit

BA-200

8.3

100

1314076

Obsolete—contact Eaton

434D316A13

Time lag fuse refill unit

BA-200

8.3

125

1314077

Obsolete—contact Eaton

434D316A14

Time lag fuse refill unit

BA-200

8.3

150

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-11

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

1314078

Obsolete—contact Eaton

434D316A15

Time lag fuse refill unit

BA-200

8.3

200

1314082

Obsolete—contact Eaton

434D316A19

Time lag fuse refill unit

BA-200

15.5

15

1314083

Obsolete—contact Eaton

434D316A20

Time lag fuse refill unit

BA-200

15.5

20

1314084

Obsolete—contact Eaton

434D316A21

Time lag fuse refill unit

BA-200

15.5

25

1314085

Obsolete—contact Eaton

434D316A22

Time lag fuse refill unit

BA-200

15.5

30

1314086

Obsolete—contact Eaton

434D316A23

Time lag fuse refill unit

BA-200

15.5

40

1314087

Obsolete—contact Eaton

434D316A24

Time lag fuse refill unit

BA-200

15.5

50

1314088

Obsolete—contact Eaton

434D316A25

Time lag fuse refill unit

BA-200

15.5

654

1314089

Obsolete—contact Eaton

434D316A26

Time lag fuse refill unit

BA-200

15.5

80

1314090

Obsolete—contact Eaton

434D316A27

Time lag fuse refill unit

BA-200

15.5

100

1314091

Obsolete—contact Eaton

434D316A28

Time lag fuse refill unit

BA-200

15.5

125

1314092

Obsolete—contact Eaton

434D316A29

Time lag fuse refill unit

BA-200

15.5

150

1314093

Obsolete—contact Eaton

434D316A30

Time lag fuse refill unit

BA-200

15.5

200

1314097

Obsolete—contact Eaton

434D316A34

Time lag fuse refill unit

BA-200

25.5

15

1314098

Obsolete—contact Eaton

434D316A35

Time lag fuse refill unit

BA-200

25.5

20

1314099

Obsolete—contact Eaton

434D316A36

Time lag fuse refill unit

BA-200

25.5

25

1314100

Obsolete—contact Eaton

434D316A37

Time lag fuse refill unit

BA-200

25.5

30

1314101

Obsolete—contact Eaton

434D316A38

Time lag fuse refill unit

BA-200

25.5

40

1314102

Obsolete—contact Eaton

434D316A39

Time lag fuse refill unit

BA-200

25.5

50

1314103

Obsolete—contact Eaton

434D316A40

Time lag fuse refill unit

BA-200

25.5

654

1314104

Obsolete—contact Eaton

434D316A41

Time lag fuse refill unit

BA-200

25.5

80

1314105

Obsolete—contact Eaton

434D316A42

Time lag fuse refill unit

BA-200

25.5

100

1314106

Obsolete—contact Eaton

434D316A43

Time lag fuse refill unit

BA-200

25.5

125

1314107

Obsolete—contact Eaton

434D316A44

Time lag fuse refill unit

BA-200

25.5

150

1314108

Obsolete—contact Eaton

434D316A45

Time lag fuse refill unit

BA-200

25.5

200

1314112

Obsolete—contact Eaton

434D316A49

Time lag fuse refill unit

BA-200

38

15

1314113

Obsolete—contact Eaton

434D316A50

Time lag fuse refill unit

BA-200

38

20

1314114

Obsolete—contact Eaton

434D316A51

Time lag fuse refill unit

BA-200

38

25

1314115

Obsolete—contact Eaton

434D316A52

Time lag fuse refill unit

BA-200

38

30

1314116

Obsolete—contact Eaton

434D316A53

Time lag fuse refill unit

BA-200

38

40

1314117

Obsolete—contact Eaton

434D316A54

Time lag fuse refill unit

BA-200

38

50

1314118

Obsolete—contact Eaton

434D316A55

Time lag fuse refill unit

BA-200

38

654

1314119

Obsolete—contact Eaton

434D316A56

Time lag fuse refill unit

BA-200

38

80

1314120

Obsolete—contact Eaton

434D316A57

Time lag fuse refill unit

BA-200

38

100

1314121

Obsolete—contact Eaton

434D316A58

Time lag fuse refill unit

BA-200

38

125

1314122

Obsolete—contact Eaton

434D316A59

Time lag fuse refill unit

BA-200

38

150

1314123

Obsolete—contact Eaton

434D316A60

Time lag fuse refill unit

BA-200

38

200

1314124

8BA4-.5E

116D977A01

Fuse refill unit

BA-400

8.3

0.5

1314125

8BA4-5E

116D977A02

Fuse refill unit

BA-400

8.3

5

1314126

8BA4-7E

116D977A03

Fuse refill unit

BA-400

8.3

7

1314127

8BA4-10E

116D977A04

Fuse refill unit

BA-400

8.3

10

1314128

8BA4-15E

116D977A05

Fuse refill unit

BA-400

8.3

15

1314129

8BA4-20E

116D977A06

Fuse refill unit

BA-400

8.3

20

1314130

8BA4-25E

116D977A07

Fuse refill unit

BA-400

8.3

25

1314131

8BA4-30E

116D977A08

Fuse refill unit

BA-400

8.3

30

1314132

8BA4-40E

116D977A09

Fuse refill unit

BA-400

8.3

40

1314133

8BA4-50E

116D977A10

Fuse refill unit

BA-400

8.3

50

1314134

8BA4-65E

116D977A11

Fuse refill unit

BA-400

8.3

654

1314135

8BA4-80E

116D977A12

Fuse refill unit

BA-400

8.3

80

1314136

8BA4-100E

116D977A13

Fuse refill unit

BA-400

8.3

100

1314137

8BA4-125E

116D977A14

Fuse refill unit

BA-400

8.3

125

1314138

8BA4-150E

116D977A15

Fuse refill unit

BA-400

8.3

150

1314139

8BA4-200E

116D977A16

Fuse refill unit

BA-400

8.3

200

V14-A2-12

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current
Rating
Amperes

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1314140

8BA4-250E

116D977A17

1314141

8BA4-300E

116D977A18

Fuse refill unit

BA-400

8.3

250

Fuse refill unit

BA-400

8.3

1314142

8BA4-400E

300

116D977A19

Fuse refill unit

BA-400

8.3

1314143

400

15BA4-.5E

116D977A01

Fuse refill unit

BA-400

15.5

0.5

1314144

15BA4-5E

116D977A02

Fuse refill unit

BA-400

15.5

5

1314145

15BA4-7E

116D977A03

Fuse refill unit

BA-400

15.5

7

1314146

15BA4-10E

116D977A04

Fuse refill unit

BA-400

15.5

10

1314147

15BA4-15E

116D977A05

Fuse refill unit

BA-400

15.5

15

1314148

15BA4-20E

116D977A06

Fuse refill unit

BA-400

15.5

20

1314149

15BA4-25E

116D977A07

Fuse refill unit

BA-400

15.5

25

1314150

15BA4-30E

116D977A08

Fuse refill unit

BA-400

15.5

30

1314151

15BA4-40E

116D977A09

Fuse refill unit

BA-400

15.5

40

1314152

15BA4-50E

116D977A10

Fuse refill unit

BA-400

15.5

50

1314153

15BA4-65E

116D977A11

Fuse refill unit

BA-400

15.5

654

1314154

15BA4-80E

116D977A12

Fuse refill unit

BA-400

15.5

80

1314155

15BA4-100E

116D977A13

Fuse refill unit

BA-400

15.5

100

1314156

15BA4-125E

116D977A14

Fuse refill unit

BA-400

15.5

125

1314157

15BA4-150E

116D977A15

Fuse refill unit

BA-400

15.5

150

1314158

15BA4-200E

116D977A16

Fuse refill unit

BA-400

15.5

200

1314159

15BA4-250E

116D977A17

Fuse refill unit

BA-400

15.5

250

1314160

15BA4-300E

116D977A18

Fuse refill unit

BA-400

15.5

300

1314161

15BA4-400E

116D977A19

Fuse refill unit

BA-400

15.5

400

1314162

25BA4-.5E

116D977A01

Fuse refill unit

BA-400

25.5

0.5

1314163

25BA4-5E

116D977A02

Fuse refill unit

BA-400

25.5

5

1314164

25BA4-7E

116D977A03

Fuse refill unit

BA-400

25.5

7

1314165

25BA4-10E

116D977A04

Fuse refill unit

BA-400

25.5

10

1314166

25BA4-15E

116D977A05

Fuse refill unit

BA-400

25.5

15

1314167

25BA4-20E

116D977A06

Fuse refill unit

BA-400

25.5

20

1314168

25BA4-25E

116D977A07

Fuse refill unit

BA-400

25.5

25

1314169

25BA4-30E

116D977A08

Fuse refill unit

BA-400

25.5

30

1314170

25BA4-40E

116D977A09

Fuse refill unit

BA-400

25.5

40

1314171

25BA4-50E

116D977A10

Fuse refill unit

BA-400

25.5

50

1314172

25BA4-65E

116D977A11

Fuse refill unit

BA-400

25.5

654

1314173

25BA4-80E

116D977A12

Fuse refill unit

BA-400

25.5

80

1314174

25BA4-100E

116D977A13

Fuse refill unit

BA-400

25.5

100

1314175

25BA4-125E

116D977A14

Fuse refill unit

BA-400

25.5

125

1314176

25BA4-150E

116D977A15

Fuse refill unit

BA-400

25.5

150

1314177

25BA4-200E

116D977A16

Fuse refill unit

BA-400

25.5

200

1314178

25BA4-250E

116D977A17

Fuse refill unit

BA-400

25.5

250

1314179

25BA4-300E

116D977A18

Fuse refill unit

BA-400

25.5

300

1314180

38BA4-.5E

116D977A01

Fuse refill unit

BA-400

38

0.5

1314181

38BA4-5E

116D977A02

Fuse refill unit

BA-400

38

5

1314182

38BA4-7E

116D977A03

Fuse refill unit

BA-400

38

7

1314183

38BA4-10E

116D977A04

Fuse refill unit

BA-400

38

10

1314184

38BA4-15E

116D977A05

Fuse refill unit

BA-400

38

15

1314185

38BA4-20E

116D977A06

Fuse refill unit

BA-400

38

20

1314186

38BA4-25E

116D977A07

Fuse refill unit

BA-400

38

25

1314187

38BA4-30E

116D977A08

Fuse refill unit

BA-400

38

30

1314188

38BA4-40E

116D977A09

Fuse refill unit

BA-400

38

40

1314189

38BA4-50E

116D977A10

Fuse refill unit

BA-400

38

50

1314190

38BA4-65E

116D977A11

Fuse refill unit

BA-400

38

654

1314191

38BA4-80E

116D977A12

Fuse refill unit

BA-400

38

80

1314192

38BA4-100E

116D977A13

Fuse refill unit

BA-400

38

100

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-13

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1314193

38BA4-125E

116D977A14

1314194

38BA4-150E

116D977A15

Fuse refill unit

BA-400

38

125

Fuse refill unit

BA-400

38

1314195

38BA4-200E

150

116D977A16

Fuse refill unit

BA-400

38

1314196

200

38BA4-250E

116D977A18

Fuse refill unit

BA-400

38

250

1314197

38BA4-300E

116D977A17

Fuse refill unit

BA-400

38

300

1314199

38BA4-250E

116D977A18

Fuse refill unit

BA-400

38

250

1318260

38DBA2-0.5

22A6782G04

—

—

—

—

1318261

38DBA2-3E

505D420G07

—

—

—

—

1318262

38DBA2-5E

18A7330G13

—

—

—

—

1318263

38DBA2-7E

18A7330G14

—

—

—

—

1318264

38DBA2-10E

18A7330G15

—

—

—

—

1318265

38DBA2-15E

18A7330G16

—

—

—

—

1318266

38DBA2-20E

18A7330G17

—

—

—

—

1318267

38DBA2-25E

18A7330G18

—

—

—

—

1318268

38DBA2-30E

18A7330G19

—

—

—

—

1318269

38DBA2-40E

18A7330G20

—

—

—

—

1318270

38DBA2-50E

18A7330G21

—

—

—

—

1318271

38DBA2-65E

18A7330G22

—

—

—

—

1318272

38DBA2-80E

18A7330G23

—

—

—

—

1318273

38DBA2-100E

18A7330G24

—

—

—

—

1318274

38DBA2-125E

18A7330G25

—

—

—

—

1318275

38DBA2-150E

18A7330G26

—

—

—

—

1318276

38DBA2-200E

18A7330G27

—

—

—

—

1318280

48DBA2-0.5

22A6782G05

—

—

—

—

1318281

48DBA2-3E

505D420G08

—

—

—

—

1318282

48DBA2-5E

18A7330G33

—

—

—

—

1318283

48DBA2-7E

18A7330G34

—

—

—

—

1318284

48DBA2-10E

18A7330G35

—

—

—

—

1318285

48DBA2-15E

18A7330G36

—

—

—

—

1318286

48DBA2-20E

18A7330G37

—

—

—

—

1318287

48DBA2-25E

18A7330G38

—

—

—

—

1318288

48DBA2-30E

18A7330G39

—

—

—

—

1318289

48DBA2-40E

18A7330G40

—

—

—

—

1318290

48DBA2-50E

18A7330G41

—

—

—

—

1318291

48DBA2-65E

18A7330G42

—

—

—

—

1318292

48DBA2-80E

18A7330G43

—

—

—

—

1318293

48DBA2-100E

18A7330G44

—

—

—

—

1318294

48DBA2-125E

18A7330G45

—

—

—

—

1318295

48DBA2-150E

18A7330G46

—

—

—

—

1318296

48DBA2-200E

18A7330G47

—

—

—

—

1318511

8BA4-NH

310C196G01

Non-disconnect fuse holder

BA-400

8.3

400

1318512

15BA4-NH

310C196G02

Non-disconnect fuse holder

BA-400

15.5

400

1318513

8BA2-NH

310C198G01

Non-disconnect fuse holder

BA-200

8.3

200

1318514

15BA2-NH

310C198G02

Non-disconnect fuse holder

BA-200

15.5

200

1318710
1318711
1318712
1318713

V14-A2-14

2CLE-50E

310C095G02

CL fuse unit

CLE

2.75

50

2CLE-50E

449D797G03

CL fuse unit

CLE

2.75

50

2CLE-65E

310C095G03

CL fuse unit

CLE

2.75

65

2CLE-65E

449D797G04

CL fuse unit

CLE

2.75

65

2CLE-80E

310C095G04

CL fuse unit

CLE

2.75

90

2CLE-80E

449D797G05

CL fuse unit

CLE

2.75

90

2CLE-100E

310C095G05

CL fuse unit

CLE

2.75

100

2CLE-100E

449D797G06

CL fuse unit

CLE

2.75

100

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number
1318714
1318715
1318716
1318720
1318721
1318722
1318723
1318724
1318725
1318726
1318727
1318728
1318730
1318731
1318732
1318733
1318734

Eaton Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

2CLE-125E

310C095G06

CL fuse unit

CLE

2.75

125

2CLE-125E

449D797G07

CL fuse unit

CLE

2.75

125

2CLE-150E

310C095G07

CL fuse unit

CLE

2.75

150

2CLE-150E

449D797G08

CL fuse unit

CLE

2.75

150

2CLE-200E

310C095G08

CL fuse unit

CLE

2.75

200

2CLE-200E

449D797G09

CL fuse unit

CLE

2.75

200

5CLE-50E

310C095G12

CL fuse unit

CLE

5.5

50

5CLE-50E

5981C65G02

CL fuse unit

CLE

5.5

50

5CLE-65E

310C095G13

CL fuse unit

CLE

5.5

65

5CLE-65E

5981C65G03

CL fuse unit

CLE

5.5

65

5CLE-80E

310C095G14

CL fuse unit

CLE

5.5

90

5CLE-80E

5981C65G04

CL fuse unit

CLE

5.5

90

5CLE-100E

310C095G15

CL fuse unit

CLE

5.5

100

5CLE-100E

5981C65G05

CL fuse unit

CLE

5.5

100

5CLE-125E

310C095G16

CL fuse unit

CLE

5.5

125

5CLE-125E

5981C65G06

CL fuse unit

CLE

5.5

125

5CLE-150E

310C095G17

CL fuse unit

CLE

5.5

150

5CLE-150E

5981C65G07

CL fuse unit

CLE

5.5

150

5CLE-200E

310C095G18

CL fuse unit

CLE

5.5

200

5CLE-200E

5981C65G09

CL fuse unit

CLE

5.5

200

8CLE-50E

5981C17G05

CL fuse unit

CLE

8.3

50

8CLE-50E

677C573G03

CL fuse unit

CLE

8.3

50

8CLE-65E

5981C17G06

CL fuse unit

CLE

8.3

65

8CLE-65E

677C573G04

CL fuse unit

CLE

8.3

65

8CLE-100E

5981C17G08

CL fuse unit

CLE

8.3

100

8CLE-100E

677C573G06

CL fuse unit

CLE

8.3

100

15CLE-50E

439D378G05

CL fuse unit

CLE

15.5

50

15CLE-50E

5981C19G05

CL fuse unit

CLE

15.5

50

15CLE-65E

439D378G06

CL fuse unit

CLE

15.5

65

15CLE-65E

5981C19G06

CL fuse unit

CLE

15.5

65

15CLE-80E

439D482G04

CL fuse unit

CLE

15.5

80

15CLE-80E

5981C19G07

CL fuse unit

CLE

15.5

80

15CLE-100E

439D482G05

CL fuse unit

CLE

15.5

100

15CLE-100E

5981C19G08

CL fuse unit

CLE

15.5

100

1318739

Obsolete—contact Eaton

505D615A02

Live parts

BA-400

—

—

1318740

Obsolete—contact Eaton

505D615A04

Live parts

BA-400

—

—

1318741

Obsolete—contact Eaton

505D615A05

Live parts

BA-400

—

—

1318742

Obsolete—contact Eaton

505D615A06

Live parts

BA-400

—

—

1318803

Obsolete—contact Eaton

505D616A03

Live parts

BA-200

—

—

1318840

Obsolete—contact Eaton

505D616A06

Live parts

BA-200

—

—

1318841

Obsolete—contact Eaton

505D616A07

Live parts

BA-200

—

—

1318842

Obsolete—contact Eaton

505D616A08

Live parts

BA-200

—

—

1318843

Obsolete—contact Eaton

505D616A09

Live parts

BA-200

—

—

1332763

2CLE-15E

678C240G01

CL fuse unit

CLE

2.75

15

1332764

2CLE-20E

678C240G02

CL fuse unit

CLE

2.75

20

1332765

2CLE-25E

678C240G03

CL fuse unit

CLE

2.75

25

1332766

5CLE-15E

678C240G04

CL fuse unit

CLE

5.5

15

1332767

5CLE-20E

678C240G05

CL fuse unit

CLE

5.5

20

1332768

5CLE-25E

678C240G06

CL fuse unit

CLE

5.5

25

1332769

8CLE-15E

678C240G07

CL fuse unit

CLE

8.3

15

1332770

8CLE-20E

678C240G08

CL fuse unit

CLE

8.3

20

1332771

8CLE-25E

678C240G09

CL fuse unit

CLE

8.3

25

1332772

15CLE-15E

678C240G10

CL fuse unit

CLE

15.5

15

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-15

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Description

1332773

15CLE-20E

678C240G11

1332774

15CLE-25E

678C240G12

1362998

Obsolete—contact Eaton

—

1363084

Obsolete—contact Eaton

505D615A03

Live parts

BA-400

—

—

1392538

2CLS-2R

591C812G02

CL fuse unit

CLS

2.54

70

1392539

2CLS-4R

591C812G04

CL fuse unit

CLS

2.54

130

1392540

2CLS-6R

591C812G06

CL fuse unit

CLS

2.54

170

1392541

2CLS-9R

591C812G07

CL fuse unit

CLS

2.54

200

1392542

2CLS-12R

591C812G08

CL fuse unit

CLS

2.54

230

1392543

2CLS-12R

591C812G08

CL fuse unit

CLS

2.54

230

1392544

5LCLS-2R

676C546G15

CL fuse unit

CLS

5.08

70

1392545

5LCLS-4R

676C546G17

CL fuse unit

CLS

5.08

130

1392546

5LCLS-6R

676C546G19

CL fuse unit

CLS

5.08

170

1392547

5LCLS-9R

676C546G22

CL fuse unit

CLS

5.08

200

1392548

5LCLS-12R

676C546G25

CL fuse unit

CLS

5.08

230

1392549

5LCLS-12R

676C546G25

CL fuse unit

CLS

5.08

230

1392788

Obsolete—contact Eaton

432D140A35

Mounting

BAL

—

—

1404766

8BA2-NH

310C198G01

Non-disconnect fuse holder

BA-200

8.3

200

1404767

15BA2-NH

310C198G02

Non-disconnect fuse holder

BA-200

15.5

200

1414114

Obsolete—contact Eaton

434D316A51

Time lag fuse refill unit

BA-200

38

25

1446152

Obsolete—contact Eaton

304C108G01

Outdoor mounting 180

BA-200

8.3

200

1446153

Obsolete—contact Eaton

304C108G02

Outdoor mounting 180

BA-200

15.5

200

1446154

Obsolete—contact Eaton

304C108G03

Outdoor mounting 180

BA-200

25.5

200

1446155

Obsolete—contact Eaton

304C108G04

Outdoor mounting 180

BA-200

38

200

1446156

Obsolete—contact Eaton

304C109G01

Outdoor mounting 180

BA-400

8.3

400

1446157

Obsolete—contact Eaton

304C109G02

Outdoor mounting 180

BA-400

15.5

400

1446158

Obsolete—contact Eaton

304C109G03

Outdoor mounting 180

BA-400

25.5

400

1446159

Obsolete—contact Eaton

304C109G04

Outdoor mounting 180

BA-400

38

400

1446293

Obsolete—contact Eaton

434D830A01

Outdoor mounting

DBA-1

8.3

200

1446294

Obsolete—contact Eaton

434D830A02

Outdoor mounting

DBA-1

15.5

200

1446295

Obsolete—contact Eaton

434D830A03

Outdoor mounting

DBA-1

25.5

200

1446296

Obsolete—contact Eaton

434D830A04

Outdoor mounting

DBA-1

38

200

1446297

Obsolete—contact Eaton

434D830A05

Outdoor mounting

DBA-1

48

200

1446298

Obsolete—contact Eaton

434D830A09

Outdoor mounting

DBA-1

72

200

1446355

Obsolete—contact Eaton

434D831A02

Outdoor mounting

DBA2/5

48

200

1446356

Obsolete—contact Eaton

434D831A09

Outdoor mounting

DBA2/5

72

200

1446357

Obsolete—contact Eaton

434D831A10

Outdoor mounting

DBA2/5

92

200

1446358

Obsolete—contact Eaton

434D831A11

Outdoor mounting

DBA2/5

121

200

1446359

Obsolete—contact Eaton

434D831A12

Outdoor mounting

DBA2/5

145

200

1481432

Obsolete—contact Eaton

304C108G05

Outdoor mounting Hi BIL

BA-200

8.3

200

1481433

Obsolete—contact Eaton

304C108G06

Outdoor mounting Hi BIL

BA-200

15.5

200

1481434

Obsolete—contact Eaton

304C108G07

Outdoor mounting Hi BIL

BA-200

25.5

200

1481435

Obsolete—contact Eaton

304C108G08

Outdoor mounting Hi BIL

BA-200

38

200

1481436

Obsolete—contact Eaton

314C109G05

Outdoor mounting Hi BIL

BA-400

8.3

400

1481437

Obsolete—contact Eaton

314C109G06

Outdoor mounting Hi BIL

BA-400

15.5

400

1481438

Obsolete—contact Eaton

314C109G07

Outdoor mounting Hi BIL

BA-400

25.5

400

1481439

Obsolete—contact Eaton

314C109G08

Outdoor mounting Hi BIL

BA-400

38

400

1482184

Obsolete—contact Eaton

505D620A02

Live parts

BA-200

—

—

1482185

Obsolete—contact Eaton

505D620A03

Live parts

BA-200

—

—

1482186

Obsolete—contact Eaton

505D620A04

Live parts

BA-200

—

—

1482187

Obsolete—contact Eaton

505D620A05

Live parts

BA-200

—

—

1482193

Obsolete—contact Eaton

505D620A01

Live parts

BA-200

—

—

1482194

Obsolete—contact Eaton

505D620A06

Live parts

BA-200

—

—

V14-A2-16

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

CL fuse unit

CLE

15.5

20

CL fuse unit

CLE

15.5

25

End fittings

CLE

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1482195

Obsolete—contact Eaton

505D620A07

1482196

Obsolete—contact Eaton

505D620A08

Live parts

BA-200

—

—

Live parts

BA-200

—

1491006

Obsolete—contact Eaton

—

414D224G06

Mounting

BA-400

38

1491007

—

Obsolete—contact Eaton

414D226G06

Mounting

BA-400

38

—

1491008

Obsolete—contact Eaton

414D225G06

Mounting

BA-400

38

—

1491009

Obsolete—contact Eaton

414D227G06

Mounting

BA-400

38

—

1491043

Obsolete—contact Eaton

505D615A07

Live parts

BA-200

—

—

1491044

Obsolete—contact Eaton

505D615A08

Live parts

BA-200

—

—

1491045

Obsolete—contact Eaton

505D615A09

Live parts

BA-200

—

—

1491046

Obsolete—contact Eaton

505D615A10

Live parts

BA-200

—

—

1491052

15CLPT-1.5E

677C452G10

CL fuse unit

CLE-PT

15.5

1.5

1508801

Obsolete—contact Eaton

676C236A01

Mounting

BAL-PT

5.5

10

1508802

Obsolete—contact Eaton

676C236A02

Mounting

BAL-PT

7.2

—

1508803

Obsolete—contact Eaton

676C236A03

Mounting

BAL-PT

7.2

—

1508804

Obsolete—contact Eaton

676C236A04

Mounting

BAL-PT

15.5

—

1508805

Obsolete—contact Eaton

676C236A05

Mounting

BAL-PT

15.5

—

1508806

Obsolete—contact Eaton

676C236A06

Mounting

BAL-PT

25.5

—

1508807

Obsolete—contact Eaton

676C236A11

Mounting

BAL-PT

5.5

—

1508808

Obsolete—contact Eaton

676C236A12

Mounting

BAL-PT

7.2

—

1508809

Obsolete—contact Eaton

676C236A13

Mounting

BAL-PT

7.2

—

1508810

Obsolete—contact Eaton

676C236A14

Mounting

BAL-PT

15.5

—

1508811

Obsolete—contact Eaton

676C236A15

Mounting

BAL-PT

15.5

—

1508812

Obsolete—contact Eaton

676C236A16

Mounting

BAL-PT

25.5

—

1508813

Obsolete—contact Eaton

676C236A21

Mounting

BAL-PT

5.5

—

1508814

Obsolete—contact Eaton

676C236A22

Mounting

BAL-PT

7.2

—

1508815

Obsolete—contact Eaton

676C236A23

Mounting

BAL-PT

7.2

—

1508816

Obsolete—contact Eaton

676C236A24

Mounting

BAL-PT

15.5

—

1508817

Obsolete—contact Eaton

676C236A25

Mounting

BAL-PT

15.5

—

1508818

Obsolete—contact Eaton

676C236A26

Mounting

BAL-PT

25.5

—

1508820

Obsolete—contact Eaton

676C233A01

Mounting

BAL-PT

5.5

—

1508821

Obsolete—contact Eaton

676C233A02

Mounting

BAL-PT

7.2

—

1508822

Obsolete—contact Eaton

676C233A03

Mounting

BAL-PT

7.2

—

1508823

Obsolete—contact Eaton

676C233A04

Mounting

BAL-PT

15.5

—

1508824

Obsolete—contact Eaton

676C233A05

Mounting

BAL-PT

15.5

—

1508825

Obsolete—contact Eaton

676C233A06

Mounting

BAL-PT

25.5

—

1508826

Obsolete—contact Eaton

676C233A09

Mounting

BAL-PT

5.5

—

1508827

Obsolete—contact Eaton

676C233A10

Mounting

BAL-PT

7.2

—

1508828

Obsolete—contact Eaton

676C233A11

Mounting

BAL-PT

7.2

—

1508829

Obsolete—contact Eaton

676C233A12

Mounting

BAL-PT

15.5

—

1508830

Obsolete—contact Eaton

676C233A13

Mounting

BAL-PT

15.5

—

1508831

Obsolete—contact Eaton

676C233A14

Mounting

BAL-PT

25.5

—

1508832

Obsolete—contact Eaton

676C233A17

Mounting

BAL-PT

5.5

—

1508833

Obsolete—contact Eaton

676C233A18

Mounting

BAL-PT

7.2

—

1508834

Obsolete—contact Eaton

676C233A19

Mounting

BAL-PT

7.2

—

1508835

Obsolete—contact Eaton

676C233A20

Mounting

BAL-PT

15.5

—

1508836

Obsolete—contact Eaton

676C233A21

Mounting

BAL-PT

15.5

—

1508837

Obsolete—contact Eaton

676C233A22

Mounting

BAL-PT

25.5

—

1508838

Obsolete—contact Eaton

676C233A25

Mounting

BAL-PT

5.5

—

1508839

Obsolete—contact Eaton

676C233A26

Mounting

BAL-PT

7.2

—

1508841

Obsolete—contact Eaton

676C233A28

Mounting

BAL-PT

15.5

—

1508842

Obsolete—contact Eaton

676C233A29

Mounting

BAL-PT

15.5

—

1508845

Obsolete—contact Eaton

676C237A01

Mounting

BAL-10

8.3

—

1508846

Obsolete—contact Eaton

676C237A02

Mounting

BAL-10

8.3

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-17

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1508847

Obsolete—contact Eaton

676C237A03

1508848

Obsolete—contact Eaton

676C237A04

Mounting

BAL-10

15.5

—

Mounting

BAL-10

15.5

1508849

Obsolete—contact Eaton

—

676C237A11

Mounting

BAL-10

8.3

1508850

—

Obsolete—contact Eaton

676C237A12

Mounting

BAL-10

8.3

—

1508851

Obsolete—contact Eaton

676C237A13

Mounting

BAL-10

15.5

—

1508852

Obsolete—contact Eaton

676C237A14

Mounting

BAL-10

15.5

—

1508853

Obsolete—contact Eaton

676C237A21

Mounting

BAL-10

8.3

—

1508854

Obsolete—contact Eaton

676C237A22

Mounting

BAL-10

8.3

—

1508855

Obsolete—contact Eaton

676C237A23

Mounting

BAL-10

15.5

—

1508856

Obsolete—contact Eaton

676C237A24

Mounting

BAL-10

15.5

—

1508858

Obsolete—contact Eaton

676C234A01

Mounting

BAL-10

8.3

—

1508859

Obsolete—contact Eaton

676C234A02

Mounting

BAL-10

8.3

—

1508860

Obsolete—contact Eaton

676C234A03

Mounting

BAL-10

15.5

—

1508861

Obsolete—contact Eaton

676C234A04

Mounting

BAL-10

15.5

—

1508862

Obsolete—contact Eaton

676C234A09

Mounting

BAL-10

8.3

—

1508863

Obsolete—contact Eaton

676C234A10

Mounting

BAL-10

8.3

—

1508864

Obsolete—contact Eaton

676C234A11

Mounting

BAL-10

15.5

—

1508865

Obsolete—contact Eaton

676C234A12

Mounting

BAL-10

15.5

—

1508866

Obsolete—contact Eaton

676C234A17

Mounting

BAL-10

8.3

—

1508867

Obsolete—contact Eaton

676C234A18

Mounting

BAL-10

8.3

—

1508868

Obsolete—contact Eaton

676C234A19

Mounting

BAL-10

15.5

—

1508869

Obsolete—contact Eaton

676C234A20

Mounting

BAL-10

15.5

—

1508870

Obsolete—contact Eaton

676C234A26

Mounting

BAL-10

8.3

—

1508871

Obsolete—contact Eaton

676C234A27

Mounting

BAL-10

8.3

—

1508872

Obsolete—contact Eaton

676C234A28

Mounting

BAL-10

15.5

—

1508873

Obsolete—contact Eaton

676C234A29

Mounting

BAL-10

15.5

—

1508875

Obsolete—contact Eaton

676C238A01

Mounting

BAL-25

2.75

—

1508876

Obsolete—contact Eaton

676C238A02

Mounting

BAL-25

5.5

—

1508877

Obsolete—contact Eaton

676C238A03

Mounting

BAL-25

5.5

—

1508878

Obsolete—contact Eaton

676C238A04

Mounting

BAL-25

5.5

—

1508879

Obsolete—contact Eaton

676C238A05

Mounting

BAL-25

8.3

—

1508880

Obsolete—contact Eaton

676C238A06

Mounting

BAL-25

8.3

—

1508881

Obsolete—contact Eaton

676C238A07

Mounting

BAL-25

15.5

—

1508882

Obsolete—contact Eaton

676C238A08

Mounting

BAL-25

15.5

—

1508883

Obsolete—contact Eaton

676C238A11

Mounting

BAL-25

2.75

—

1508884

Obsolete—contact Eaton

676C238A12

Mounting

BAL-25

2.75

—

1508885

Obsolete—contact Eaton

676C238A13

Mounting

BAL-25

5.5

—

1508886

Obsolete—contact Eaton

676C238A14

Mounting

BAL-25

5.5

—

1508887

Obsolete—contact Eaton

676C238A15

Mounting

BAL-25

8.3

—

1508888

Obsolete—contact Eaton

676C238A16

Mounting

BAL-25

8.3

—

1508889

Obsolete—contact Eaton

676C238A17

Mounting

BAL-25

15.5

—

1508890

Obsolete—contact Eaton

676C238A18

Mounting

BAL-25

15.5

—

1508891

Obsolete—contact Eaton

676C238A21

Mounting

BAL-25

5.5

—

1508892

Obsolete—contact Eaton

676C238A22

Mounting

BAL-25

2.75

—

1508893

Obsolete—contact Eaton

151D244G26

Disconnect live parts RC

CLE

—

—

1508894

Obsolete—contact Eaton

676C238A24

Mounting

BAL-25

5.5

—

1508895

Obsolete—contact Eaton

676C238A25

Mounting

BAL-25

8.3

—

1508896

Obsolete—contact Eaton

676C238A26

Mounting

BAL-25

8.3

—

1508897

Obsolete—contact Eaton

676C238A27

Mounting

BAL-25

15.5

—

1508898

Obsolete—contact Eaton

676C238A28

Mounting

BAL-25

15.5

—

1508900

Obsolete—contact Eaton

676C231A01

Mounting

BAL-25

2.75

—

1508901

Obsolete—contact Eaton

676C231A02

Mounting

BAL-25

5.5

—

1508902

Obsolete—contact Eaton

676C231A03

Mounting

BAL-25

5.5

—

V14-A2-18

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1508903

Obsolete—contact Eaton

676C231A04

1508904

Obsolete—contact Eaton

676C231A05

Mounting

BAL-25

5.5

—

Mounting

BAL-25

8.3

1508905

Obsolete—contact Eaton

—

676C231A06

Mounting

BAL-25

8.3

1508906

—

Obsolete—contact Eaton

676C231A07

Mounting

BAL-25

15.5

—

1508907

Obsolete—contact Eaton

676C231A08

Mounting

BAL-25

15.5

—

1508908

Obsolete—contact Eaton

676C231A09

Mounting

BAL-25

2.75

—

1508909

Obsolete—contact Eaton

676C231A10

Mounting

BAL-25

5.5

—

1508910

Obsolete—contact Eaton

676C231A11

Mounting

BAL-25

5.5

—

1508911

Obsolete—contact Eaton

676C231A12

Mounting

BAL-25

5.5

—

1508912

Obsolete—contact Eaton

676C231A13

Mounting

BAL-25

8.3

—

1508913

Obsolete—contact Eaton

676C231A14

Mounting

BAL-25

8.3

—

1508914

Obsolete—contact Eaton

676C231A15

Mounting

BAL-25

15.5

—

1508915

Obsolete—contact Eaton

676C231A16

Mounting

BAL-25

15.5

—

1508916

Obsolete—contact Eaton

676C231A17

Mounting

BAL-25

2.75

—

1508917

Obsolete—contact Eaton

676C231A18

Mounting

BAL-25

5.5

—

1508918

Obsolete—contact Eaton

676C231A19

Mounting

BAL-25

5.5

—

1508919

Obsolete—contact Eaton

676C231A20

Mounting

BAL-25

5.5

—

1508920

Obsolete—contact Eaton

676C231A21

Mounting

BAL-25

8.3

—

1508921

Obsolete—contact Eaton

676C231A22

Mounting

BAL-25

8.3

—

1508922

Obsolete—contact Eaton

676C231A23

Mounting

BAL-25

15.5

—

1508923

Obsolete—contact Eaton

676C231A24

Mounting

BAL-25

15.5

—

1508924

Obsolete—contact Eaton

676C231A25

Mounting

BAL-25

2.75

—

1508925

Obsolete—contact Eaton

676C231A26

Mounting

BAL-25

5.5

—

1508926

Obsolete—contact Eaton

676C231A27

Mounting

BAL-25

5.5

—

1508927

Obsolete—contact Eaton

676C231A28

Mounting

BAL-25

5.5

—

1508928

Obsolete—contact Eaton

676C231A29

Mounting

BAL-25

8.3

—

1508929

Obsolete—contact Eaton

676C231A30

Mounting

BAL-25

8.3

—

1508930

Obsolete—contact Eaton

676C231A31

Mounting

BAL-25

15.5

—

1508931

Obsolete—contact Eaton

676C231A32

Mounting

BAL-25

15.5

—

1508933

Obsolete—contact Eaton

308C427A01

Mounting

BAL-200

2.75

—

1508934

Obsolete—contact Eaton

308C427A02

Mounting

BAL-200

5.5

—

1508935

Obsolete—contact Eaton

308C427A03

Mounting

BAL-200

5.5

—

1508936

Obsolete—contact Eaton

308C427A04

Mounting

BAL-200

8.3

—

1508937

Obsolete—contact Eaton

308C427A05

Mounting

BAL-200

8.3

—

1508938

Obsolete—contact Eaton

308C427A06

Mounting

BAL-200

15.5

—

1508939

15CLE-HPNM-D

9078A68G19

CLE mounting

CLE-1

15.5

—

1508940

Obsolete—contact Eaton

308C427A10

CLE mounting, rear connected

CLE-1

2.75

—

1508941

Obsolete—contact Eaton

308C427A11

CLE mounting

CLE-1

5.5

—

1508942

Obsolete—contact Eaton

308C427A12

CLE mounting

CLE-1

5.5

—

1508943

Obsolete—contact Eaton

308C427A13

CLE mounting

CLE-1

8.3

—

1508944

Obsolete—contact Eaton

308C427A14

CLE mounting

CLE-1

8.3

—

1508945

Obsolete—contact Eaton

308C427A15

CLE mounting

CLE-1

15.5

—

1508946

Obsolete—contact Eaton

308C427A16

CLE mounting

CLE-1

15.5

—

1508947

Obsolete—contact Eaton

308C427A19

CLE mounting

CLE-1

2.75

—

1508948

Obsolete—contact Eaton

308C427A20

CLE mounting

CLE-1

5.5

—

1508949

Obsolete—contact Eaton

308C427A21

CLE mounting

CLE-1

5.5

—

1508950

Obsolete—contact Eaton

308C427A22

CLE mounting

CLE-1

8.3

—

1508951

Obsolete—contact Eaton

308C427A23

CLE mounting

CLE-1

8.3

—

1508952

Obsolete—contact Eaton

308C427A24

CLE mounting

CLE-1

15.5

—

1508953

Obsolete—contact Eaton

308C427A25

CLE mounting

CLE-1

15.5

—

1508954

Obsolete—contact Eaton

151D907G25

Live parts, rear connected

CLE-1

—

—

1508955

—

432D140A01

CLE mounting

CLE-1

2.75

—

1508956

—

432D140A02

CLE mounting

CLE-1

5.5

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-19

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1508957

—

432D140A05

1508958

—

432D140A06

CLE mounting

CLE-1

5.5

—

CLE mounting

CLE-1

8.3

1508959

—

—

432D140A09

CLE mounting

CLE-1

8.3

1508960

—

—

432D140A10

CLE mounting

CLE-1

15.5

—

1508961

—

432D140A11

CLE mounting

CLE-1

15.5

—

1508962

—

432D140A12

CLE mounting

CLE-1

2.75

—

1508963

—

432D140A13

CLE mounting

CLE-1

5.5

—

1508964

—

432D140A15

CLE mounting

CLE-1

5.5

—

1508965

—

432D140A16

CLE mounting

CLE-1

8.3

—

1508966

—

432D140A19

CLE mounting

CLE-1

8.3

—

1508967

—

432D140A20

CLE mounting

CLE-1

15.5

—

1508968

—

432D140A21

CLE mounting

CLE-1

15.5

—

1508969

—

432D140A22

CLE mounting

CLE-1

2.75

—

1508970

—

432D140A23

CLE mounting

CLE-1

5.5

—

1508971

—

432D140A25

CLE mounting

CLE-1

5.5

—

1508972

—

432D140A26

CLE mounting

CLE-1

8.3

—

1508973

—

432D140A29

CLE mounting

CLE-1

8.3

—

1508974

—

432D140A30

CLE mounting

CLE-1

15.5

—

1508975

—

432D140A31

CLE mounting

CLE-1

15.5

—

1508976

—

432D140A32

CLE mounting

CLE-1

2.75

—

1508977

—

432D140A33

CLE mounting

CLE-1

5.5

—

1508978

—

432D140A35

CLE mounting

CLE-1

5.5

—

1508979

—

432D140A36

CLE mounting

CLE-1

8.3

—

1508980

—

432D140A39

CLE mounting

CLE-1

8.3

—

1508981

—

432D140A40

CLE mounting

CLE-1

15.5

—

1508982

—

432D140A41

CLE mounting

CLE-1

15.5

—

1529011

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

72

15

1529012

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

72

20

1529013

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

72

25

1529014

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

72

30

1529015

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

72

40

1529016

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

72

50

1529017

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

72

65

1529018

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

72

80

1529019

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

72

100

1529020

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

72

125

1529021

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

72

150

1529022

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

72

200

1529074

Obsolete—contact Eaton

434D317A05

Time lag fuse refill unit

BA-400

8.3

20

1529075

Obsolete—contact Eaton

434D317A06

Time lag fuse refill unit

BA-400

8.3

25

1529076

Obsolete—contact Eaton

434D317A07

Time lag fuse refill unit

BA-400

8.3

30

1529077

Obsolete—contact Eaton

434D317A08

Time lag fuse refill unit

BA-400

8.3

40

1529078

Obsolete—contact Eaton

434D317A09

Time lag fuse refill unit

BA-400

8.3

50

1529079

Obsolete—contact Eaton

434D317A10

Time lag fuse refill unit

BA-400

8.3

65

1529080

Obsolete—contact Eaton

434D317A11

Time lag fuse refill unit

BA-400

8.3

80

1529081

Obsolete—contact Eaton

434D317A12

Time lag fuse refill unit

BA-400

8.3

100

1529082

Obsolete—contact Eaton

434D317A13

Time lag fuse refill unit

BA-400

8.3

125

1529083

Obsolete—contact Eaton

434D317A14

Time lag fuse refill unit

BA-400

8.3

150

1529084

Obsolete—contact Eaton

434D317A15

Time lag fuse refill unit

BA-400

8.3

200

1529085

Obsolete—contact Eaton

434D317A23

Time lag fuse refill unit

BA-400

15.5

20

1529086

Obsolete—contact Eaton

434D317A24

Time lag fuse refill unit

BA-400

15.5

25

1529087

Obsolete—contact Eaton

434D317A25

Time lag fuse refill unit

BA-400

15.5

30

1529088

Obsolete—contact Eaton

434D317A26

Time lag fuse refill unit

BA-400

15.5

40

V14-A2-20

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1529089

Obsolete—contact Eaton

434D317A27

1529090

Obsolete—contact Eaton

434D317A28

Time lag fuse refill unit

BA-400

15.5

50

Time lag fuse refill unit

BA-400

15.5

1529091

Obsolete—contact Eaton

65

434D317A29

Time lag fuse refill unit

BA-400

15.5

1529092

80

Obsolete—contact Eaton

434D317A30

Time lag fuse refill unit

BA-400

15.5

100

1529093

Obsolete—contact Eaton

434D317A31

Time lag fuse refill unit

BA-400

15.5

125

1529094

Obsolete—contact Eaton

434D317A32

Time lag fuse refill unit

BA-400

15.5

150

1529095

Obsolete—contact Eaton

434D317A33

Time lag fuse refill unit

BA-400

15.5

200

1529096

Obsolete—contact Eaton

434D317A41

Time lag fuse refill unit

BA-400

25.5

20

1529097

Obsolete—contact Eaton

434D317A42

Time lag fuse refill unit

BA-400

25.5

25

1529098

Obsolete—contact Eaton

434D317A43

Time lag fuse refill unit

BA-400

25.5

30

1529099

Obsolete—contact Eaton

434D317A44

Time lag fuse refill unit

BA-400

25.5

40

1529100

Obsolete—contact Eaton

434D317A45

Time lag fuse refill unit

BA-400

25.5

50

1529101

Obsolete—contact Eaton

434D317A46

Time lag fuse refill unit

BA-400

25.5

65

1529102

Obsolete—contact Eaton

434D317A47

Time lag fuse refill unit

BA-400

25.5

80

1529103

Obsolete—contact Eaton

434D317A48

Time lag fuse refill unit

BA-400

25.5

100

1529104

Obsolete—contact Eaton

434D317A49

Time lag fuse refill unit

BA-400

25.5

125

1529105

Obsolete—contact Eaton

434D317A50

Time lag fuse refill unit

BA-400

25.5

150

1529106

Obsolete—contact Eaton

434D317A51

Time lag fuse refill unit

BA-400

25.5

200

1529107

Obsolete—contact Eaton

434D317A59

Time lag fuse refill unit

BA-400

38

20

1529108

Obsolete—contact Eaton

434D317A60

Time lag fuse refill unit

BA-400

38

25

1529109

Obsolete—contact Eaton

434D317A61

Time lag fuse refill unit

BA-400

38

30

1529110

Obsolete—contact Eaton

434D317A62

Time lag fuse refill unit

BA-400

38

40

1529111

Obsolete—contact Eaton

434D317A63

Time lag fuse refill unit

BA-400

38

50

1529112

Obsolete—contact Eaton

434D317A64

Time lag fuse refill unit

BA-400

38

65

1529113

Obsolete—contact Eaton

434D317A65

Time lag fuse refill unit

BA-400

38

80

1529114

Obsolete—contact Eaton

434D317A66

Time lag fuse refill unit

BA-400

38

100

1529115

Obsolete—contact Eaton

434D317A67

Time lag fuse refill unit

BA-400

38

125

1529116

Obsolete—contact Eaton

434D317A68

Time lag fuse refill unit

BA-400

38

150

1529117

Obsolete—contact Eaton

434D317A69

Time lag fuse refill unit

BA-400

38

200

1533412

Obsolete—contact Eaton

505D616A05

Live parts

BA-200

—

—

1533413

Obsolete—contact Eaton

505D616A04

Live parts

BA-200

—

—

1533505

—

676C237A05

CLE mounting

CLE-PT

5.5

10

1533506

—

676C237A15

CLE mounting

CLE-PT

5.5

10

1533507

—

676C237A25

CLE mounting

CLE-PT

5.5

10

1533508

—

676C234A05

CLE mounting

CLE-PT

5.5

10

1533509

—

676C234A13

CLE mounting

CLE-PT

5.5

10

1533510

—

676C234A21

CLE mounting

CLE-PT

5.5

10

1533511

—

676C234A30

CLE mounting

CLE-PT

5.5

10

1533754

Obsolete—contact Eaton

677C593G03

CL fuse unit

CLV

0.6

7

1533755

Obsolete—contact Eaton

677C593G04

CL fuse unit

CLV

0.6

10

1533840

2CLS-4R

676C546G04

CL fuse unit

CLS

2.54

130

1573979

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

121

15

1573980

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

121

20

1573981

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

121

25

1573982

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

121

30

1573983

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

121

40

1573984

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

121

50

1573985

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

121

65

1573986

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

121

80

1573987

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

121

100

1573988

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

121

125

1573989

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

121

150

1573990

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

121

200

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-21

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Description

1574576

Obsolete—contact Eaton

423D140A07

1574577

Obsolete—contact Eaton

423D140A27

1574578

Obsolete—contact Eaton

423D140A24

1574579

Obsolete—contact Eaton

423D140A04

Mounting

BAL

2.75

—

1576468

2CLE-30E

310C095G10

CL fuse unit

CLE

2.75

30

2CLE-30E

449D797G02

CL fuse unit

CLE

2.75

30

2CLE-40E

449D797G12

CL fuse unit

CLE

2.75

40

2CLE-40E

676C546G01

CL fuse unit

CLE

2.75

40

1576469
1576470
1576471
1576472
1576473
1576474
1576475

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Mounting

BAL

5.5

—

Mounting

BAL

5.5

—

Mounting

BAL

2.75

—

5CLE-30E

310C095G20

CL fuse unit

CLE

5.5

30

5CLE-30E

5981C29G05

CL fuse unit

CLE

5.5

30

5CLE-40E

5981C65G01

CL fuse unit

CLE

5.5

40

5CLE-40E

676C546G14

CL fuse unit

CLE

5.5

40

8CLE-30E

5981C31G05

CL fuse unit

CLE

8.3

30

8CLE-30E

677C573G01

CL fuse unit

CLE

8.3

30

8CLE-40E

5981C17G04

CL fuse unit

CLE

8.3

40

8CLE-40E

677C573G02

CL fuse unit

CLE

8.3

40

15CLE-30E

439D378G03

CL fuse unit

CLE

15.5

30

15CLE-30E

5981C33G05

CL fuse unit

CLE

15.5

30

15CLE-40E

439D378G04

CL fuse unit

CLE

15.5

40

15CLE-40E

5981C19G04

CL fuse unit

CLE

15.5

40

1584339

Obsolete—contact Eaton

434D831A01

Mounting

DBA2/5

—

—

1585177

Obsolete—contact Eaton

423D770G05

Outdoor fuse holder vented

BA-400

8.3

—

1585178

Obsolete—contact Eaton

423D770G06

Outdoor fuse holder vented

BA-400

15.5

—

1585179

Obsolete—contact Eaton

423D770G07

Outdoor fuse holder vented

BA-400

25.5

—

1585180

Obsolete—contact Eaton

423D770G08

Outdoor fuse holder vented

BA-400

38

—

1585181

Obsolete—contact Eaton

423D770G09

Outdoor fuse holder vented

BA-400

8.3

—

1585182

Obsolete—contact Eaton

423D770G10

Outdoor fuse holder vented

BA-400

15.5

—

1585183

Obsolete—contact Eaton

423D770G11

Outdoor fuse holder vented

BA-400

25.5

—

1585184

Obsolete—contact Eaton

423D770G12

Outdoor fuse holder vented

BA-400

38

—

1585232

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

96

15

1585233

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

96

20

1585234

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

96

25

1585235

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

96

30

1585236

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

96

40

1585237

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

96

50

1585238

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

96

65

1585239

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

96

80

1585240

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

96

100

1585241

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

96

125

1585242

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

96

150

1585243

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

96

200

1585245

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

145

15

1585246

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

145

20

1585247

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

145

25

1585248

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

145

30

1585249

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

145

40

1585250

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

145

50

1585251

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

145

65

1585252

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

145

80

1585253

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

145

100

1585254

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

145

125

1585255

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

145

150

1585256

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

145

200

V14-A2-22

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1585319

2NCLPT-2E

677C592G04

1585385

Obsolete—contact Eaton

117D122G05

CL fuse unit

NCLE-PT

2.75

2

Disconnect fuse holder

BA-200

8.3

1585386

Obsolete—contact Eaton

—

117D122G06

Disconnect fuse holder

BA-200

15.5

—

1585387
1585388

Obsolete—contact Eaton

117D122G07

Disconnect fuse holder

BA-200

25.5

—

Obsolete—contact Eaton

117D122G08

Disconnect fuse holder

BA-200

38

—

1585389

Obsolete—contact Eaton

117D122G01

Disconnect fuse holder

BA-200

8.3

—

1585390

Obsolete—contact Eaton

117D122G02

Disconnect fuse holder

BA-200

15.5

—

1585391

Obsolete—contact Eaton

117D122G03

Disconnect fuse holder

BA-200

25.5

—

1585392

Obsolete—contact Eaton

117D122G04

Disconnect fuse holder

BA-200

38

—

1585393

Obsolete—contact Eaton

676C880G01

Disconnect fuse holder

BA-400

8.3

—

1585394

Obsolete—contact Eaton

676C880G02

Disconnect fuse holder

BA-400

15.5

—

1585395

Obsolete—contact Eaton

676C880G03

Disconnect fuse holder

BA-400

25.5

—

1585396

Obsolete—contact Eaton

676C880G04

Disconnect fuse holder

BA-400

38

—

1585490

Obsolete—contact Eaton

505D616A02

Live parts

BA-200

—

—

1585492

5CLPT-1E

677C452G06

CL fuse unit

CLE-PT

5.5

1

1594922

RBA2-COND

310C197G03

Condenser (3 pack)

BA-200/RBA-200

—

—

1594923

RBA2-COND

310C197G03

Condenser (3 pack)

BA-200/RBA-200

—

—

1611883

Obsolete—contact Eaton

423D140A08

Mounting

BAL

5.5

—

1611884

Obsolete—contact Eaton

423D140A28

Mounting

BAL

5.5

—

1616388

RBA4-COND

310C197G04

Condenser (3 pack)

BA-400/RBA-400

—

—

1616389

RBA4-COND

310C197G04

Condenser (3 pack)

BA-400/RBA-400

—

—

1616747

Obsolete—contact Eaton

30A6178G01

Mounting

BA-800

—

—

1616748

Obsolete—contact Eaton

30A6178G02

Mounting

BA-800

—

—

1802143

Obsolete—contact Eaton

60A1307G01

Mounting

BA-800

—

—

1804417

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

72

15

1804418

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

72

20

1804419

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

72

25

1804420

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

72

30

1804421

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

72

40

1804422

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

72

50

1804423

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

72

65

1804424

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

72

80

1804425

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

72

100

1804426

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

72

125

1804427

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

72

150

1804428

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

72

200

1804429

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

0.5

1804430

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

3E

1804431

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

5E

1804432

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

7E

1804433

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

10E

1804434

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

15E

1804435

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

20E

1804436

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

25E

1804437

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

30E

1804438

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

40

1804439

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

50

1804440

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

65

1804441

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

80

1804442

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

100

1804443

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

125

1804444

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

150

1804445

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

38.0

200

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-23

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1804446

Obsolete—contact Eaton

—

1804447

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

0.5

DBA5 fuse assembly

DBA-5

48.3

1804448

Obsolete—contact Eaton

3E

—

DBA5 fuse assembly

DBA-5

48.3

1804449

5E

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

7E

1804450

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

10E

1804451

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

15E

1804452

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

20E

1804453

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

25E

1804454

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

30E

1804455

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

40

1804456

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

50

1804457

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

65

1804458

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

80

1804459

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

100

1804460

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

125

1804461

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

150

1804462

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

48.3

200

1804463

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

0.5

1804464

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

3E

1804465

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

5E

1804466

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

7E

1804467

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

10E

1804468

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

15E

1804469

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

20E

1804470

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

25E

1804471

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

30E

1804472

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

40

1804473

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

50

1804474

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

65

1804475

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

80

1804476

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

100

1804477

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

125

1804478

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

150

1804479

Obsolete—contact Eaton

—

DBA5 fuse assembly

DBA-5

72.5

200

1804577

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

38

15

1804578

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

38

20

1804579

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

38

25

1804580

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

38

30

1804581

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

38

40

1804582

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

38

50

1804583

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

38

65

1804584

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

38

80

1804585

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

38

100

1804586

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

38

125

1804587

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

38

150

1804588

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

38

200

1804589

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

48

15

1804590

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

48

20

1804591

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

48

25

1804592

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

48

30

1804593

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

48

40

1804594

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

48

50

1804595

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

48

65

V14-A2-24

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1804596

Obsolete—contact Eaton

—

1804597

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

48

80

Time lag fuse unit

DBA-5

48

1804598

Obsolete—contact Eaton

100

—

Time lag fuse unit

DBA-5

48

1804599

125

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

48

150

1804600

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-5

48

200

1804601

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

38

15

1804602

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

38

20

1804603

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

38

25

1804604

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

38

30

1804605

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

38

40

1804606

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

38

50

1804607

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

38

65

1804608

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

38

80

1804609

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

38

100

1804610

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

38

125

1804611

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

38

150

1804612

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

38

200

1804613

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

48

15

1804614

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

48

20

1804615

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

48

25

1804616

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

48

30

1804617

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

48

40

1804618

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

48

50

1804619

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

48

65

1804620

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

48

80

1804621

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

48

100

1804622

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

48

125

1804623

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

48

150

1804624

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-2

48

200

1804654

5LCLS-2R

676C546G15

CL fuse unit

CLS

5.5

70

1804655

5LCLS-4R

676C546G17

CL fuse unit

CLS

5.5

130

1804656

5LCLS-6R

676C546G19

CL fuse unit

CLS

5.5

170

1804657

5LCLS-9R

676C546G22

CL fuse unit

CLS

5.5

200

1804658

5LCLS-12R

676C546G25

CL fuse unit

CLS

5.5

230

1804760

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

8.3

15

1804761

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

8.3

20

1804762

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

8.3

25

1804763

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

8.3

30

1804764

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

8.3

40

1804765

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

8.3

50

1804766

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

8.3

65

1804767

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

8.3

80

1804768

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

8.3

100

1804769

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

8.3

125

1804770

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

8.3

150

1804771

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

8.3

200

1804772

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

15.5

15

1804773

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

15.5

20

1804774

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

15.5

25

1804775

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

15.5

30

1804776

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

15.5

40

1804777

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

15.5

50

1804778

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

15.5

65

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-25

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1804779

Obsolete—contact Eaton

—

1804780

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

15.5

80

Time lag fuse unit

DBA-1

15.5

1804781

Obsolete—contact Eaton

100

—

Time lag fuse unit

DBA-1

15.5

1804782

125

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

15.5

150

1804783

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

15.5

200

1804784

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

25.5

15

1804785

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

25.5

20

1804786

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

25.5

25

1804787

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

25.5

30

1804788

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

25.5

40

1804789

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

25.5

50

1804790

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

25.5

65

1804791

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

25.5

80

1804792

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

25.5

100

1804793

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

25.5

125

1804794

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

25.5

150

1804795

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

25.5

200

1804796

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

38

15

1804797

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

38

20

1804798

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

38

25

1804799

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

38

30

1804800

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

38

40

1804801

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

38

50

1804802

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

38

65

1804803

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

38

80

1804804

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

38

100

1804805

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

38

125

1804806

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

38

150

1804807

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

38

200

1804808

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

48

15

1804809

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

48

20

1804810

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

48

25

1804811

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

48

30

1804812

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

48

40

1804813

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

48

50

1804814

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

48

65

1804815

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

48

80

1804816

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

48

100

1804817

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

48

125

1804818

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

48

150

1804819

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

48

200

1804820

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

72

15

1804821

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

72

20

1804822

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

72

25

1804823

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

72

30

1804824

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

72

40

1804825

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

72

50

1804826

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

72

65

1804827

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

72

80

1804828

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

72

100

1804829

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

72

125

1804830

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

72

150

1804831

Obsolete—contact Eaton

—

Time lag fuse unit

DBA-1

72

200

V14-A2-26

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Westinghouse
6/7 Digit
Style Number

Eaton Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

1804860

2CLS-18R

591C813G01

1804861

2CLS-24R

591C813G02

CL fuse unit

CLS

2.54

390

CL fuse unit

CLS

2.54

1804862

5LCLS-18R

450

304C463G03

CL fuse unit

CLS

5.08

1804863

390

5LCLS-24R

304C463G04

CL fuse unit

CLS

5.08

450

1804880

Obsolete—contact Eaton

116D412A02

Mounting

BAL-LR

5.08

—

1804881

Obsolete—contact Eaton

116D412A09

Mounting

BAL-LR

8.3

—

1804882

Obsolete—contact Eaton

116D412A02

Mounting

BAL-LR

5.08

—

1804883

Obsolete—contact Eaton

116D412A09

Mounting

BAL-LR

8.3

—

1804884

Obsolete—contact Eaton

116D412A02

Mounting

BAL-LR

5.08

—

1804885

Obsolete—contact Eaton

116D412A09

Mounting

BAL-LR

8.3

—

1804886

Obsolete—contact Eaton

116D412A13

Mounting

BAL-LR

5.08

—

1804887

Obsolete—contact Eaton

116D412A19

Mounting

BAL-LR

8.3

—

1804888

Obsolete—contact Eaton

116D412A23

Mounting

BAL-LR

5.08

—

1804889

Obsolete—contact Eaton

116D412A29

Mounting

BAL-LR

8.3

—

1804890

Obsolete—contact Eaton

116D412A33

Mounting

BAL-LR

5.08

—

1804891

Obsolete—contact Eaton

116D412A39

Mounting

BAL-LR

8.3

—

1804892

Obsolete—contact Eaton

116D412A05

Mounting

BAL-LR

5.08

—

1804893

Obsolete—contact Eaton

116D412A05

Mounting

BAL-LR

5.08

—

1804894

Obsolete—contact Eaton

116D412A05

Mounting

BAL-LR

5.08

—

1804895

Obsolete—contact Eaton

116D412A15

Mounting

BAL-LR

5.08

—

1804896

Obsolete—contact Eaton

116D412A25

Mounting

BAL-LR

5.08

—

1804897

Obsolete—contact Eaton

116D412A35

Mounting

BAL-LR

5.08

—

1804898

Obsolete—contact Eaton

667C774G14

Live parts

BAL-LR

—

—

1804899

Obsolete—contact Eaton

667C774G14

Live parts

BAL-LR

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-27

Appendix 2—Superseded Style Number Index
10 Character Style Numbers
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

116D412A02

2CLE-PDM-E

9078A65G20

116D412A05

5CLE-PDM-E

9078A65G21

—

CLE

2.75

450

—

CLE

5.5

116D412A06

5CLE-PDM-E

450

9078A65G21

—

CLE

5.5

116D412A09

450

8CLE-PDM-E

9078A65G22

—

CLE

8.3

350

116D412A11

15CLE-PDM-E

9078A65G23

—

CLE

15.5

300

116D412A13

Obsolete—contact Eaton

—

2.4 kV top rear con. mounting

CLE

2.75

450

116D412A15

Obsolete—contact Eaton

—

4.8 kV top rear con. mounting

CLE

5.5

450

116D412A16

Obsolete—contact Eaton

—

4.8 kV top rear con. mounting

CLE

5.5

450

116D412A19

Obsolete—contact Eaton

—

7.2 kV top rear con. mounting

CLE

8.3

350

116D412A21

Obsolete—contact Eaton

—

14.4 kV top rear con. mounting

CLE

15.5

300

116D412A23

Obsolete—contact Eaton

—

2.4 kV double rear con. mounting

CLE

2.75

450

116D412A25

Obsolete—contact Eaton

—

4.8 kV double rear con. mounting

CLE

5.5

450

116D412A26

Obsolete—contact Eaton

—

4.8 kV double rear con. mounting

CLE

5.5

450

116D412A29

Obsolete—contact Eaton

—

7.2 kV double rear con. mounting

CLE

8.3

350

116D412A31

Obsolete—contact Eaton

—

14.4 kV double rear con. mounting

CLE

15.5

300

116D412A33

Obsolete—contact Eaton

—

2.4 kV bottom rear con. mounting

CLE

2.75

450

116D412A35

Obsolete—contact Eaton

—

4.8 kV bottom rear con. mounting

CLE

5.5

450

116D412A36

Obsolete—contact Eaton

—

4.8 kV bottom rear con. mounting

CLE

5.5

450

116D412A39

Obsolete—contact Eaton

—

7.2 kV bottom rear con. mounting

CLE

8.3

350

116D412A41

Obsolete—contact Eaton

—

14.4 kV bottom rear con. mounting

CLE

15.5

300

116D977A1

8BA4-.5E

116D977A1

—

BA4

8.3

0.5

116D977A2

8BA4-5E

116D977A2

—

BA4

8.3

5

116D977A3

8BA4-7E

116D977A3

—

BA4

8.3

7E

116D977A4

8BA4-10E

116D977A4

—

BA4

8.3

10 E

116D977A5

8BA4-15E

116D977A5

—

BA4

8.3

15 E

116D977A6

8BA4-20E

116D977A6

—

BA4

8.3

20 E

116D977A7

8BA4-25E

116D977A7

—

BA4

8.3

25 E

116D977A8

8BA4-30E

116D977A8

—

BA4

8.3

30 E

116D977A9

8BA4-40E

116D977A9

—

BA4

8.3

40 E

116D977A10

8BA4-50E

116D977A10

—

BA4

8.3

50 E

116D977A11

8BA4-65E

116D977A11

—

BA4

8.3

65 E

116D977A12

8BA4-80E

116D977A12

—

BA4

8.3

80 E

116D977A13

8BA4-100E

116D977A13

—

BA4

8.3

100 E

116D977A14

8BA4-125E

116D977A14

—

BA4

8.3

125 E

116D977A15

8BA4-150E

116D977A15

—

BA4

8.3

150 E

116D977A16

8BA4-200E

116D977A16

—

BA4

8.3

200 E

116D977A17

8BA4-250E

116D977A17

—

BA4

8.3

250 E

116D977A18

8BA4-300E

116D977A18

—

BA4

8.3

300 E

116D977A19

8BA4-400E

116D977A19

—

BA4

8.3

400 E

116D977A21

15BA4-.5E

116D977A21

—

BA4

15.5

0.5

116D977A22

15BA4-5E

116D977A22

—

BA4

15.5

5

116D977A23

15BA4-7E

116D977A23

—

BA4

15.5

7E

116D977A24

15BA4-10E

116D977A24

—

BA4

15.5

10 E

116D977A25

15BA4-15E

116D977A25

—

BA4

15.5

15 E

116D977A26

15BA4-20E

116D977A26

—

BA4

15.5

20 E

116D977A27

15BA4-25E

116D977A27

—

BA4

15.5

25 E

116D977A28

15BA4-30E

116D977A28

—

BA4

15.5

30 E

116D977A29

15BA4-40E

116D977A29

—

BA4

15.5

40 E

116D977A30

15BA4-50E

116D977A30

—

BA4

15.5

50 E

116D977A31

15BA4-65E

116D977A31

—

BA4

15.5

65 E

V14-A2-28

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

116D977A32

15BA4-80E

116D977A32

116D977A33

15BA4-100E

116D977A33

—

BA4

15.5

80 E

—

BA4

15.5

116D977A34

15BA4-125E

100 E

116D977A34

—

BA4

15.5

116D977A35

125 E

15BA4-150E

116D977A35

—

BA4

15.5

150 E

116D977A36

15BA4-200E

116D977A36

—

BA4

15.5

200 E

116D977A37

15BA4-250E

116D977A37

—

BA4

15.5

250 E

116D977A48

15BA4-300E

116D977A48

—

BA4

15.5

300 E

116D977A39

15BA4-400E

116D977A39

—

BA4

15.5

400 E

116D977A41

25BA4-.5E

116D977A41

—

BA4

25

0.5

116D977A42

25BA4-5E

116D977A42

—

BA4

25

5

116D977A43

25BA4-7E

116D977A43

—

BA4

25

7E

116D977A44

25BA4-10E

116D977A44

—

BA4

25

10 E

116D977A45

25BA4-15E

116D977A45

—

BA4

25

15 E

116D977A46

25BA4-20E

116D977A46

—

BA4

25

20 E

116D977A47

25BA4-25E

116D977A47

—

BA4

25

25 E

116D977A48

25BA4-30E

116D977A48

—

BA4

25

30 E

116D977A49

25BA4-40E

116D977A49

—

BA4

25

40 E

116D977A50

25BA4-50E

116D977A50

—

BA4

25

50 E

116D977A51

25BA4-65E

116D977A51

—

BA4

25

65 E

116D977A52

25BA4-80E

116D977A52

—

BA4

25

80 E

116D977A53

25BA4-100E

116D977A53

—

BA4

25

100 E

116D977A54

25BA4-125E

116D977A54

—

BA4

25

125 E

116D977A55

25BA4-150E

116D977A55

—

BA4

25

150 E

116D977A56

25BA4-200E

116D977A56

—

BA4

25

200 E

116D977A57

25BA4-250E

116D977A57

—

BA4

25

250 E

116D977A58

25BA4-300E

116D977A58

—

BA4

25

300 E

116D977A61

38BA4-.5E

116D977A61

—

BA4

38

0.5

116D977A62

38BA4-5E

116D977A62

—

BA4

38

5

116D977A63

38BA4-7E

116D977A63

—

BA4

38

7E

116D977A64

38BA4-10E

116D977A64

—

BA4

38

10 E

116D977A65

38BA4-15E

116D977A65

—

BA4

38

15 E

116D977A66

38BA4-20E

116D977A66

—

BA4

38

20 E

116D977A67

38BA4-25E

116D977A67

—

BA4

38

25 E

116D977A68

38BA4-30E

116D977A68

—

BA4

38

30 E

116D977A69

38BA4-40E

116D977A69

—

BA4

38

40 E

116D977A70

38BA4-50E

116D977A70

—

BA4

38

50 E

116D977A71

38BA4-65E

116D977A71

—

BA4

38

65 E

116D977A72

38BA4-80E

116D977A72

—

BA4

38

80 E

116D977A73

38BA4-100E

116D977A73

—

BA4

38

100 E

116D977A74

38BA4-125E

116D977A74

—

BA4

38

125 E

116D977A75

38BA4-150E

116D977A75

—

BA4

38

150 E

116D977A76

38BA4-200E

116D977A76

—

BA4

38

200 E

116D977A77

38BA4-250E

116D977A77

—

BA4

38

250 E

116D977A78

38BA4-300E

116D977A78

—

BA4

38

300 E

117D122G01

Obsolete—contact Eaton

—

Obsolete BA2 disconnect fuse holders

—

—

—

117D122G02

Obsolete—contact Eaton

—

Obsolete BA2 disconnect fuse holders

—

—

—

117D122G03

Obsolete—contact Eaton

—

Obsolete BA2 disconnect fuse holders

—

—

—

117D122G04

Obsolete—contact Eaton

—

Obsolete BA2 disconnect fuse holders

—

—

—

117D122G05

Obsolete—contact Eaton

—

Obsolete BA2 disconnect fuse holders

—

—

—

117D122G06

Obsolete—contact Eaton

—

Obsolete BA2 disconnect fuse holders

—

—

—

117D122G07

Obsolete—contact Eaton

—

Obsolete BA2 disconnect fuse holders

—

—

—

117D122G08

Obsolete—contact Eaton

—

Obsolete BA2 disconnect fuse holders

—

—

—

117D123A01

8BA2-.5E

117D123A01

—

BA2

8.3

0.5

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-A2-29

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

117D123A02

8BA2-5E

117D123A02

117D123A03

8BA2-7E

117D123A03

—

BA2

8.3

5

—

BA2

8.3

117D123A04

8BA2-10E

7E

117D123A04

—

BA2

8.3

10 E

117D123A05
117D123A06

8BA2-15E

117D123A05

—

BA2

8.3

15 E

8BA2-20E

117D123A06

—

BA2

8.3

20 E

117D123A07

8BA2-25E

117D123A07

—

BA2

8.3

25 E

117D123A08

8BA2-30E

117D123A08

—

BA2

8.3

30 E

117D123A09

8BA2-40E

117D123A09

—

BA2

8.3

40 E

117D123A10

8BA2-50E

117D123A10

—

BA2

8.3

50 E

117D123A11

8BA2-65E

117D123A11

—

BA2

8.3

65 E

117D123A12

8BA2-80E

117D123A12

—

BA2

8.3

80 E

117D123A13

8BA2-100E

117D123A13

—

BA2

8.3

100 E

117D123A14

8BA2-125E

117D123A14

—

BA2

8.3

125 E

117D123A15

8BA2-150E

117D123A15

—

BA2

8.3

150 E

117D123A16

8BA2-200E

117D123A16

—

BA2

8.3

200 E

117D123A17

15BA2-.5E

117D123A17

—

BA2

15.5

0.5

117D123A18

15BA2-5E

117D123A18

—

BA2

15.5

5

117D123A19

15BA2-7E

117D123A19

—

BA2

15.5

7E

117D123A20

15BA2-10E

117D123A20

—

BA2

15.5

10 E

117D123A21

15BA2-15E

117D123A21

—

BA2

15.5

15 E

117D123A22

15BA2-20E

117D123A22

—

BA2

15.5

20 E

117D123A23

15BA2-25E

117D123A23

—

BA2

15.5

25 E

117D123A24

15BA2-30E

117D123A24

—

BA2

15.5

30 E

117D123A25

15BA2-40E

117D123A25

—

BA2

15.5

40 E

117D123A26

15BA2-50E

117D123A26

—

BA2

15.5

50 E

117D123A27

15BA2-65E

117D123A27

—

BA2

15.5

65 E

117D123A28

15BA2-80E

117D123A28

—

BA2

15.5

80 E

117D123A29

15BA2-100E

117D123A29

—

BA2

15.5

100 E

117D123A30

15BA2-125E

117D123A30

—

BA2

15.5

125 E

117D123A31

15BA2-150E

117D123A31

—

BA2

15.5

150 E

117D123A32

15BA2-200E

117D123A32

—

BA2

15.5

200 E

117D123A33

25BA2-.5E

117D123A33

—

BA2

25

0.5

117D123A34

25BA2-5E

117D123A34

—

BA2

25

5

117D123A35

25BA2-7E

117D123A35

—

BA2

25

7E

117D123A36

25BA2-10E

117D123A36

—

BA2

25

10 E

117D123A37

25BA2-15E

117D123A37

—

BA2

25

15 E

117D123A48

25BA2-20E

117D123A48

—

BA2

25

20 E

117D123A39

25BA2-25E

117D123A39

—

BA2

25

25 E

117D123A40

25BA2-30E

117D123A40

—

BA2

25

30 E

117D123A41

25BA2-40E

117D123A41

—

BA2

25

40 E

117D123A42

25BA2-50E

117D123A42

—

BA2

25

50 E

117D123A43

25BA2-65E

117D123A43

—

BA2

25

65 E

117D123A44

25BA2-80E

117D123A44

—

BA2

25

80 E

117D123A45

25BA2-100E

117D123A45

—

BA2

25

100 E

117D123A46

25BA2-125E

117D123A46

—

BA2

25

125 E

117D123A47

25BA2-150E

117D123A47

—

BA2

25

150 E

117D123A48

25BA2-200E

117D123A48

—

BA2

25

200 E

117D123A49

38BA2-.5E

117D123A49

—

BA2

38

0.5

117D123A50

38BA2-5E

117D123A50

—

BA2

38

5

117D123A51

38BA2-7E

117D123A51

—

BA2

38

7E

117D123A52

38BA2-10E

117D123A52

—

BA2

38

10 E

117D123A53

38BA2-15E

117D123A53

—

BA2

38

15 E

117D123A54

38BA2-20E

117D123A54

—

BA2

38

20 E

V14-A2-30

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

117D123A55

38BA2-25E

117D123A55

117D123A56

38BA2-30E

117D123A56

—

BA2

38

25 E

—

BA2

38

117D123A57

38BA2-40E

30 E

117D123A57

—

BA2

38

117D123A58

40 E

38BA2-50E

117D123A58

—

BA2

38

50 E

117D123A59

38BA2-65E

117D123A59

—

BA2

38

65 E

117D123A60

38BA2-80E

117D123A60

—

BA2

38

80 E

117D123A61

38BA2-100E

117D123A61

—

BA2

38

100 E

117D123A62

38BA2-125E

117D123A62

—

BA2

38

125 E

117D123A63

38BA2-150E

117D123A63

—

BA2

38

150 E

117D123A64

38BA2-200E

117D123A64

—

BA2

38

200 E

11A8127G02

72DBA2-5E

11A8127G02

—

DBA-2

72

5

11A8127G03

72DBA2-7E

11A8127G03

—

DBA-2

72

7E

11A8127G04

72DBA2-10E

11A8127G04

—

DBA-2

72

10 E

11A8127G05

72DBA2-15E

11A8127G05

—

DBA-2

72

15 E

11A8127G06

72DBA2-20E

11A8127G06

—

DBA-2

72

20 E

11A8127G07

72DBA2-25E

11A8127G07

—

DBA-2

72

25 E

11A8127G08

72DBA2-30E

11A8127G08

—

DBA-2

72

30 E

11A8127G09

72DBA2-40E

11A8127G09

—

DBA-2

72

40 E

11A8127G10

72DBA2-50E

11A8127G10

—

DBA-2

72

50 E

11A8127G11

72DBA2-65E

11A8127G11

—

DBA-2

72

65 E

11A8127G12

72DBA2-80E

11A8127G12

—

DBA-2

72

80 E

11A8127G13

72DBA2-100E

11A8127G13

—

DBA-2

72

100 E

11A8127G14

72DBA2-125E

11A8127G14

—

DBA-2

72

125 E

11A8127G15

72DBA2-150E

11A8127G15

—

DBA-2

72

150 E

11A8127G16

72DBA2-200E

11A8127G16

—

DBA-2

72

200 E

11A8127G21

92DBA2-3E

11A8127G21

—

DBA-2

92

3

11A8127G22

92DBA2-5E

11A8127G22

—

DBA-2

92

5

11A8127G23

92DBA2-7E

11A8127G23

—

DBA-2

92

7E

11A8127G24

92DBA2-10E

11A8127G24

—

DBA-2

92

10 E

11A8127G25

92DBA2-15E

11A8127G25

—

DBA-2

92

15 E

11A8127G26

92DBA2-20E

11A8127G26

—

DBA-2

92

20 E

11A8127G27

92DBA2-25E

11A8127G27

—

DBA-2

92

25 E

11A8127G28

92DBA2-30E

11A8127G28

—

DBA-2

92

30 E

11A8127G29

92DBA2-40E

11A8127G29

—

DBA-2

92

40 E

11A8127G30

92DBA2-50E

11A8127G30

—

DBA-2

92

50 E

11A8127G31

92DBA2-65E

11A8127G31

—

DBA-2

92

65 E

11A8127G32

92DBA2-80E

11A8127G32

—

DBA-2

92

80 E

11A8127G33

92DBA2-100E

11A8127G33

—

DBA-2

92

100 E

11A8127G34

92DBA2-125E

11A8127G34

—

DBA-2

92

125 E

11A8127G35

92DBA2-150E

11A8127G35

—

DBA-2

92

150 E

11A8127G36

92DBA2-200E

11A8127G36

—

DBA-2

92

200 E

11A8127G41

121DBA2-3E

11A8127G41

—

DBA-2

121

3

11A8127G42

121DBA2-5E

11A8127G42

—

DBA-2

121

5

11A8127G43

121DBA2-7E

11A8127G43

—

DBA-2

121

7E

11A8127G44

121DBA2-10E

11A8127G44

—

DBA-2

121

10 E

11A8127G45

121DBA2-15E

11A8127G45

—

DBA-2

121

15 E

11A8127G46

121DBA2-20E

11A8127G46

—

DBA-2

121

20 E

11A8127G47

121DBA2-25E

11A8127G47

—

DBA-2

121

25 E

11A8127G48

121DBA2-30E

11A8127G48

—

DBA-2

121

30 E

11A8127G49

121DBA2-40E

11A8127G49

—

DBA-2

121

40 E

11A8127G50

121DBA2-50E

11A8127G50

—

DBA-2

121

50 E

11A8127G51

121DBA2-65E

11A8127G51

—

DBA-2

121

65 E

11A8127G52

121DBA2-80E

11A8127G52

—

DBA-2

121

80 E

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-A2-31

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

11A8127G53

121DBA2-100E

11A8127G53

11A8127G54

121DBA2-125E

11A8127G54

—

DBA-2

121

100 E

—

DBA-2

121

11A8127G55

121DBA2-150E

125 E

11A8127G55

—

DBA-2

121

11A8127G56

150 E

121DBA2-200E

11A8127G56

—

DBA-2

121

200 E

11A8127G61

145DBA2-3E

11A8127G61

—

DBA-2

145

3

11A8127G62

145DBA2-5E

11A8127G62

—

DBA-2

145

5

11A8127G63

145DBA2-7E

11A8127G63

—

DBA-2

145

7E

11A8127G64

145DBA2-10E

11A8127G64

—

DBA-2

145

10 E

11A8127G65

145DBA2-15E

11A8127G65

—

DBA-2

145

15 E

11A8127G66

145DBA2-20E

11A8127G66

—

DBA-2

145

20 E

11A8127G67

145DBA2-25E

11A8127G67

—

DBA-2

145

25 E

11A8127G68

145DBA2-30E

11A8127G68

—

DBA-2

145

30 E

11A8127G69

145DBA2-40E

11A8127G69

—

DBA-2

145

40 E

11A8127G70

145DBA2-50E

11A8127G70

—

DBA-2

145

50 E

11A8127G71

145DBA2-65E

11A8127G71

—

DBA-2

145

65 E

11A8127G72

145DBA2-80E

11A8127G72

—

DBA-2

145

80 E

11A8127G73

145DBA2-100E

11A8127G73

—

DBA-2

145

100 E

11A8127G74

145DBA2-125E

11A8127G74

—

DBA-2

145

125 E

11A8127G75

145DBA2-150E

11A8127G75

—

DBA-2

145

150 E

11A8127G76

145DBA2-200E

11A8127G76

—

DBA-2

145

200 E

11A8128G08

Obsolete—contact Eaton

—

DBA-2 end fittings

—

—

—

129D686G01

5ACLS-24R

151D933G04

—

CLS

5.08

24R(450)

129D686G02

5ACLS-18R

151D933G03

—

CLS

5.08

18R((390)

129D696G01

5ACLS-30

449D597G01

—

CLS

5.08

30

129D696G02

5ACLS-2R

449D597G02

—

CLS

5.08

2R(70)

129D696G03

5ACLS-3R

449D597G03

—

CLS

5.08

3R(!100)

129D696G04

5ACLS-4R

449D597G04

—

CLS

5.08

4R(130)

129D696G05

5ACLS-5R

449D597G05

—

CLS

5.08

5R(150)

129D696G06

5ACLS-6R

449D597G06

—

CLS

5.08

6R(170)

129D696G07

5ACLS-9R

151D933G01

—

CLS

5.08

9R(200)

129D696G08

5ACLS-12R

151D933G02

—

CLS

5.08

12R(230)

12A4519G03

CLE-DF-E

9078A63G04

—

CLE

—

450

13C8904G01

Obsolete—contact Eaton

—

Low voltage BAL fuses

—

—

—

13C8904G02

Obsolete—contact Eaton

—

Low voltage BAL fuses

—

—

—

13C8904G03

Obsolete—contact Eaton

—

Low voltage BAL fuses

—

—

—

13C8904G04

Obsolete—contact Eaton

—

Low voltage BAL fuses

—

—

—

13C8904G05

Obsolete—contact Eaton

—

Low voltage BAL fuses

—

—

—

140D045G01

5CLS70-32R

140D045G01

—

CLS

5.08

32R(600)

140D045G02

5CLS70-36R

140D045G02

—

CLS

5.08

36R(650)

140D045G03

5CLS70-24R

140D045G03

—

CLS

5.08

24R450)

140D045G04

5CLS70-12R

140D045G04

—

CLS

5.08

12R(230)

140D045G05

5CLS70-44R

140D045G05

—

CLS

5.08

44R(700)

140D045G06

5CLS70-18R

140D045G06

—

CLS

5.08

18R(390)

140D144G01

Obsolete—contact Eaton

—

RBA-200 conversion kit

—

—

—

140D144G02

Obsolete—contact Eaton

—

RBA-200 conversion kit

—

—

—

140D144G03

Obsolete—contact Eaton

—

RBA-200 conversion kit

—

—

—

140D144G04

Obsolete—contact Eaton

—

RBA-200 conversion kit

—

—

—

140D144G05

Obsolete—contact Eaton

—

RBA-200 conversion kit

—

—

—

140D144G06

Obsolete—contact Eaton

—

RBA-200 conversion kit

—

—

—

140D144G07

Obsolete—contact Eaton

—

RBA-200 conversion kit

—

—

—

140D144G08

Obsolete—contact Eaton

—

RBA-200 conversion kit

—

—

—

140D144G09

Obsolete—contact Eaton

—

RBA-400 conversion kit

—

—

—

140D144G10

Obsolete—contact Eaton

—

RBA-400 conversion kit

—

—

—

V14-A2-32

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

140D144G11

Obsolete—contact Eaton

—

140D144G12

Obsolete—contact Eaton

—

RBA-400 conversion kit

—

—

—

RBA-400 conversion kit

—

—

140D144G13

Obsolete—contact Eaton

—

—

RBA-400 conversion kit

—

—

140D144G14

—

Obsolete—contact Eaton

—

RBA-400 conversion kit

—

—

—

140D144G15

Obsolete—contact Eaton

—

RBA-400 conversion kit

—

—

—

140D144G16

Obsolete—contact Eaton

—

RBA-400 conversion kit

—

—

—

140D180G01

Obsolete—contact Eaton

—

Sealed 5LCLS-24R

—

—

—

140D181G02

Obsolete—contact Eaton

—

Sealed 5LCLS-18R

—

—

—

140D309A01

RDB2-VL

140D309A01

—

RDB2

—

200

140D309G01

Obsolete—contact Eaton

—

8RDB2-VM—obsolete cap and pin insulators

—

—

—

140D309G02

Obsolete—contact Eaton

—

15RDB2-VM—obsolete cap and pin insulators

—

—

—

140D309G03

Obsolete—contact Eaton

—

25RDB2-VM—obsolete cap and pin insulators

—

—

—

140D309G04

Obsolete—contact Eaton

—

38RDB2-VM—obsolete cap and pin insulators

—

—

—

140D309G05

Obsolete—contact Eaton

—

8RDB2-HVM—obsolete cap and pin insulators

—

—

—

140D309G06

Obsolete—contact Eaton

—

15RDB2-HVM—obsolete cap and pin insulators

—

—

—

140D309G07

Obsolete—contact Eaton

—

25RDB2-HVM—obsolete cap and pin insulators

—

—

—

140D309G08

Obsolete—contact Eaton

—

38RDB2-HVM—obsolete cap and pin insulators

—

—

—

140D309G09

8RDB2-VM

140D309G09

Station post insulators

RDB2

8.3

200

140D309G10

15RDB2-VM

140D309G10

Station post insulators

RDB2

15.5

200

140D309G11

25RDB2-VM

140D309G11

Station post insulators

RDB2

25

200

140D309G12

38RDB2-VM

140D309G12

Station post insulators

RDB2

38

200

140D309G13

8RDB2-HVM

140D309G13

Station post insulators

RDB2

8.3

200

140D309G14

15RDB2-HVM

140D309G14

Station post insulators

RDB2

15.5

200

140D309G15

25RDB2-HVM

140D309G15

Station post insulators

RDB2

25

200

140D309G16

38RDB2-HVM

140D309G16

Station post insulators

RDB2

38

200

140D310A01

RDB4-VL

140D310A01

—

RDB4

—

400

140D310G01

Obsolete—contact Eaton

—

8RDB4-VM—obsolete cap and pin insulators

—

—

—

140D310G02

Obsolete—contact Eaton

—

15RDB4-VM—obsolete cap and pin insulators

—

—

—

140D310G03

Obsolete—contact Eaton

—

25RDB4-VM—obsolete cap and pin insulators

—

—

—

140D310G04

Obsolete—contact Eaton

—

38RDB4-VM—obsolete cap and pin insulators

—

—

—

140D310G05

Obsolete—contact Eaton

—

8RDB4-HVM—obsolete cap and pin insulators

—

—

—

140D310G06

Obsolete—contact Eaton

—

15RDB4-HVM—obsolete cap and pin insulators

—

—

—

140D310G07

Obsolete—contact Eaton

—

25RDB4-HVM—obsolete cap and pin insulators

—

—

—

140D310G08

Obsolete—contact Eaton

—

38RDB4-HVM—obsolete cap and pin insulators

—

—

—

140D310G09

8RDB4-VM

140D310G09

Station post insulators

RDB4

8.3

400

140D310G10

15RDB4-VM

140D310G10

Station post insulators

RDB4

15.5

400

140D310G11

25RDB4-VM

140D310G11

Station post insulators

RDB4

25

300

140D310G12

38RDB4-VM

140D310G12

Station post insulators

RDB4

38

300

140D310G13

8RDB4-HVM

140D310G13

Station post insulators

RDB4

8.3

400

140D310G14

15RDB4-HVM

140D310G14

Station post insulators

RDB4

15.5

400

140D310G15

25RDB4-HVM

140D310G15

Station post insulators

RDB4

25

300

140D310G16

38RDB4-HVM

140D310G16

Station post insulators

RDB4

38

300

140D311A01

RDB8-VL

140D311A01

—

RDB8

—

720

140D311G01

Obsolete—contact Eaton

—

8RDB8-VM—obsolete cap and pin insulators

—

—

—

140D311G02

Obsolete—contact Eaton

—

15RDB8-VM—obsolete cap and pin insulators

—

—

—

140D311G03

Obsolete—contact Eaton

—

25RDB8-VM—obsolete cap and pin insulators

—

—

—

140D311G04

Obsolete—contact Eaton

—

38RDB8-VM—obsolete cap and pin insulators

—

—

—

140D311G05

Obsolete—contact Eaton

—

8RDB8-HVM—obsolete cap and pin insulators

—

—

—

140D311G06

Obsolete—contact Eaton

—

15RDB8-HVM—obsolete cap and pin insulators

—

—

—

140D311G07

Obsolete—contact Eaton

—

25RDB8-HVM—obsolete cap and pin insulators

—

—

—

140D311G08

Obsolete—contact Eaton

—

38RDB8-HVM—obsolete cap and pin insulators

—

—

—

140D311G09

8RDB8-VM

140D311G09

Station post insulators

RDB8

8.3

720

140D311G10

15RDB8-VM

140D311G10

Station post insulators

RDB8

15.5

720

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-A2-33

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

140D311G11

25RDB8-VM

140D311G11

140D311G12

38RDB8-VM

140D311G12

Station post insulators

RDB8

25

540

Station post insulators

RDB8

38

140D311G13

8RDB8-HVM

540

140D311G13

Station post insulators

RDB8

8.3

140D311G14

720

15RDB8-HVM

140D311G14

Station post insulators

RDB8

15.5

720

140D311G15

25RDB8-HVM

140D311G15

Station post insulators

RDB8

25

540

140D311G16

38RDB8-HVM

140D311G16

Station post insulators

RDB8

38

540

140D316G01

6DSL-A150

140D316G01

—

DSL

0.6

160

140D316G02

6DSL-A250

140D316G02

—

DSL

0.6

200

140D316G03

6DSL-A300

140D316G03

—

DSL

0.6

300

140D316G04

6DSL-A400

140D316G04

—

DSL

0.6

400

140D316G05

6DSL-A500

140D316G05

—

DSL

0.6

500

140D316G06

6DSL-A600

140D316G06

—

DSL

0.6

600

140D316G07

6DSL-A800

140D316G07

—

DSL

0.6

800

140D316G10

6DSL-B1200

140D316G10

—

DSL

0.6

1200

140D316G11

6DSL-B1600

140D316G11

—

DSL

0.6

1600

140D316G12

6DSL-B2000

140D316G12

—

DSL

0.6

2000

140D316G15

6DSL-C800

151D932G01

—

DSL

0.6

800

140D316G16

6DSL-C1000

151D932G02

—

DSL

0.6

1000

140D316G17

6DSL-C1200

151D932G03

—

DSL

0.6

1200

140D316G18

6DSL-C1600

151D932G04

—

DSL

0.6

1600

140D316G19

6DSL-C2000

151D932G05

—

DSL

0.6

2000

140D316G21

6DSL-D2500

151D932G09

—

DSL

0.6

2500

140D316G22

6DSL-D3000

151D932G10

—

DSL

0.6

3000

140D318G01

4NPL-1875

140D318G01

—

NPL

0.48

1875

140D318G02

4NPL-2825

140D318G02

—

NPL

0.48

2825

140D318G04

4NPL-900

140D318G04

—

NPL

0.48

900

140D318G05

4NPL-1300

140D318G05

—

NPL

0.48

1300

140D318G06

4NPL-3000

140D318G06

—

NPL

0.48

3000

140D318G07

4NPL-2000

140D318G07

—

NPL

0.48

2000

140D318G08

4NPL-3500

140D318G08

—

NPL

0.48

3500

140D331G02

Obsolete—contact Eaton

—

2.4/4.8 kV RBA2 loadbreak mounting back connected

—

—

—

140D331G03

Obsolete—contact Eaton

—

2.4/4.8 kV RBA2 loadbreak mounting back connected

—

—

—

140D331G04

Obsolete—contact Eaton

—

2.4/4.8 kV RBA2 loadbreak mounting back connected

—

—

—

140D331G06

Obsolete—contact Eaton

—

7.2 kV RBA2 loadbreak mounting back connected

—

—

—

140D331G07

Obsolete—contact Eaton

—

7.2 kV RBA2 loadbreak mounting back connected

—

—

—

140D331G08

Obsolete—contact Eaton

—

7.2 kV RBA2 loadbreak mounting back connected

—

—

—

140D331G10

Obsolete—contact Eaton

—

13.8 kV RBA2 loadbreak mounting back connected

—

—

—

140D331G11

Obsolete—contact Eaton

—

13.8 kV RBA2 loadbreak mounting back connected

—

—

—

140D331G12

Obsolete—contact Eaton

—

13.8 kV RBA2 loadbreak mounting back connected

—

—

—

140D331G14

Obsolete—contact Eaton

—

14.4 kV RBA2 loadbreak mounting back connected

—

—

—

140D331G15

Obsolete—contact Eaton

—

14.4 kV RBA2 loadbreak mounting back connected

—

—

—

140D331G16

Obsolete—contact Eaton

—

14.4 kV RBA2 loadbreak mounting back connected

—

—

—

140D332G02

Obsolete—contact Eaton

—

2.4/4.8 kV RBA4 loadbreak mounting back connected

—

—

—

140D332G03

Obsolete—contact Eaton

—

2.4/4.8 kV RBA4 loadbreak mounting back connected

—

—

—

140D332G04

Obsolete—contact Eaton

—

2.4/4.8 kV RBA4 loadbreak mounting back connected

—

—

—

140D332G06

Obsolete—contact Eaton

—

7.2 kV RBA4 loadbreak mounting back connected

—

—

—

140D332G07

Obsolete—contact Eaton

—

7.2 kV RBA4 loadbreak mounting back connected

—

—

—

140D332G08

Obsolete—contact Eaton

—

7.2 kV RBA4 loadbreak mounting back connected

—

—

—

140D332G10

Obsolete—contact Eaton

—

13.8 kV RBA4 loadbreak mounting back connected

—

—

—

140D332G11

Obsolete—contact Eaton

—

13.8 kV RBA4 loadbreak mounting back connected

—

—

—

140D332G12

Obsolete—contact Eaton

—

13.8 kV RBA4 loadbreak mounting back connected

—

—

—

140D332G14

Obsolete—contact Eaton

—

14.4 kV RBA4 loadbreak mounting back connected

—

—

—

140D332G15

Obsolete—contact Eaton

—

14.4 kV RBA4 loadbreak mounting back connected

—

—

—

V14-A2-34

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

140D332G16

Obsolete—contact Eaton

—

140D332G18

Obsolete—contact Eaton

—

14.4 kV RBA4 loadbreak mounting back connected

—

—

—

23 kV RBA4 loadbreak mounting back connected

—

—

140D332G19

Obsolete—contact Eaton

—

—

24 kV RBA4 loadbreak mounting back connected

—

—

140D332G20

—

Obsolete—contact Eaton

—

25 kV RBA4 loadbreak mounting back connected

—

—

—

140D340G11

8RDB2-VM

140D340G11

—

RDB2

8.3

200

140D340G12

15RDB2-VM

140D340G12

—

RDB2

15.5

200

140D340G13

25RDB2-VM

140D340G13

—

RDB2

25

200

140D340G14

38RDB2-VM

140D340G14

—

RDB2

38

200

140D340G16

8RDB2-HVM

140D340G16

—

RDB2

8.3

200

140D340G17

15RDB2-HVM

140D340G17

—

RDB2

15.5

200

140D340G18

25RDB2-HVM

140D340G18

—

RDB2

25

200

140D340G19

38RDB2-HVM

140D340G19

—

RDB2

38

200

140D340G20

RDB2-VL

140D340G20

—

RDB2

—

200

140D341G11

8RDB4-VM

140D341G11

—

RDB4

8.3

400

140D341G12

15RDB4-VM

140D341G12

—

RDB4

15.5

400

140D341G13

25RDB4-VM

140D341G13

—

RDB4

25

300

140D341G14

38RDB4-VM

140D341G14

—

RDB4

38

300

140D341G16

8RDB4-HVM

140D341G16

—

RDB4

8.3

400

140D341G17

15RDB4-HVM

140D341G17

—

RDB4

15.5

400

140D341G18

25RDB4-HVM

140D341G18

—

RDB4

25

400

140D341G19

38RDB4-HVM

140D341G19

—

RDB4

38

300

140D341G20

RDB4-VL

140D341G20

—

RDB4

—

300

140D342G11

8RDB8-VM

140D342G11

—

RDB8

8.3

720

140D342G12

15RDB8-VM

140D342G12

—

RDB8

15.5

720

140D342G13

25RDB8-VM

140D342G13

—

RDB8

25

540

140D342G14

38RDB8-VM

140D342G14

—

RDB8

38

540

140D342G16

8RDB8-HVM

140D342G16

—

RDB8

8.3

720

140D342G17

15RDB8-HVM

140D342G17

—

RDB8

15.5

720

140D342G18

25RDB8-HVM

140D342G18

—

RDB8

25

540

140D342G19

38RDB8-HVM

140D342G19

—

RDB8

38

540

140D342G20

RDB8-VL

140D342G20

—

RDB8

—

720

140D346G11

8RDB2-UM

140D346G11

—

RDB2

8.3

200

140D346G12

15RDB2-UM

140D346G12

—

RDB2

15.5

200

140D346G13

25RDB2-UM

140D346G13

—

RDB2

25

200

140D346G14

38RDB2-UM

140D346G14

—

RDB2

38

200

140D346G16

8RDB2-HUM

140D346G16

—

RDB2

8.3

200

140D346G17

15RDB2-HUM

140D346G17

—

RDB2

15.5

200

140D346G18

25RDB2-HUM

140D346G18

—

RDB2

25

200

140D346G19

38RDB2-HUM

140D346G19

—

RDB2

38

200

140D346G20

RDB2-UL

140D346G20

—

RDB2

—

200

140D349G11

8RDB4-UM

140D349G11

—

RDB4

8.3

400

140D349G12

15RDB4-UM

140D349G12

—

RDB4

15.5

400

140D349G13

25RDB4-UM

140D349G13

—

RDB4

25

300

140D349G14

38RDB4-UM

140D349G14

—

RDB4

38

300

140D349G16

8RDB4-HUM

140D349G16

—

RDB4

8.3

400

140D349G17

15RDB4-HUM

140D349G17

—

RDB4

15.5

400

140D349G18

25RDB4-HUM

140D349G18

—

RDB4

25

400

140D349G19

38RDB4-HUM

140D349G19

—

RDB4

38

300

140D349G20

RDB4-UL

140D349G20

—

RDB4

—

300

140D354G11

8RDB8-UM

140D354G11

—

RDB8

8.3

720

140D354G12

15RDB8-UM

140D354G12

—

RDB8

15.5

720

140D354G13

25RDB8-UM

140D354G13

—

RDB8

25

540

140D354G14

38RDB8-UM

140D354G14

—

RDB8

38

540

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-A2-35

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

140D354G16

8RDB8-HUM

140D354G16

—

RDB8

8.3

720

140D354G17

15RDB8-HUM

140D354G17

—

RDB8

15.5

720

140D354G18

25RDB8-HUM

140D354G18

—

RDB8

25

540

140D354G19

38RDB8-HUM

140D354G19

—

RDB8

38

540

140D354G20

RDB8-UL

140D354G20

—

RDB8

—

720

140D204G01

8CXN-60C

9570D01G01

—

CXN

8.3

60C

140D204G02

8CXN-100C

9570D01G02

—

CXN

8.3

100C

140D204G03

8CXN-125C

9570D01G03

—

CXN

8.3

125C

140D204G04

8CXN-150C

9570D01G04

—

CXN

8.3

150C

140D204G05

8CXN-200C

9570D01G05

—

CXN

8.3

200C

140D204G06

8CXN-250C

9570D01G06

—

CXN

8.3

250C

151D207G01

4ACLS-26R

151D207G01

—

CLS

4.6

26R(480)

151D213G01

15CLE-10E

5981C33G01

15CLO-10E

CLE

15.5

10E

151D213G02

15CLE-20E-D

5981C33G03

15CLO-20E

CLE

15.5

20E

151D213G03

15CLE-30E

5981C33G05

15CLO-30E

CLE

15.5

30E

151D213G04

15CLE-40E

5981C19G04

15CLO-40E

CLE

15.5

40E

151D213G05

15CLE-50E

5981C19G05

15CLO-50E

CLE

15.5

50E

151D213G06

15CLE-65E

5981C19G06

15CLO-65E

CLE

15.5

65E

151D213G09

15CLE-50E

5981C19G05

15CLO-50E

CLE

15.5

50E

151D213G10

15CLE-65E

5981C19G06

15CLO-65E

CLE

15.5

60E

151D213G11

Obsolete—contact Eaton

—

15CLO-10E (NI)

—

—

—

151D213G12

Obsolete—contact Eaton

—

15CLO-20E (NI)

—

—

—

151D213G13

Obsolete—contact Eaton

—

15CLO-30E (NI)

—

—

—

151D213G14

Obsolete—contact Eaton

—

15CLO-40E (NI)

—

—

—

151D213G15

Obsolete—contact Eaton

—

15CLO-50E (NI)

—

—

—

151D213G16

Obsolete—contact Eaton

—

15CLO-65E (NI)

—

—

—

151D214G04

15CLE-80E

5981C19G07

15CLO-80E

CLE

15.5

80E

151D214G05

15CLE-100E

5981C19G08

15CLO-100E

CLE

15.5

100E

151D214G06

15CLE-125E

5981C19G09

15CLO-125E

CLE

15.5

125E

151D218G02

15CXN-45C

9570D02G02

—

CXN

15.5

45C

151D218G03

15CXN-60C

9570D02G03

—

CXN

15.5

60V

151D218G04

15CXN-75C

9570D02G04

—

CXN

15.5

75C

151D218G05

15CXN-85C

9570D02G05

—

CXN

15.5

85C

151D218G06

15CXN-100C

9570D02G06

—

CXN

15.5

100C

151D240G01

5HCLS-30

151D240G01

—

CLS

5.08

30

151D240G02

5HCLS-2R

151D240G02

—

CLS

5.08

2R(70)

151D240G03

5HCLS-3R

151D240G03

—

CLS

5.08

3R(100)

151D240G04

5HCLS-4R

151D240G04

—

CLS

5.08

4R(130)

151D240G05

5HCLS-4R

151D240G05

—

CLS

5.08

5R(150)

151D240G06

5HCLS-6R

151D240G06

—

CLS

5.08

6R(170)

151D241G01

5CLS-30

151D241G01

—

CLS

5.08

30

151D241G02

5CLS-2R

151D241G02

—

CLS

5.08

2R(70)

151D241G03

5CLS-3R

151D241G03

—

CLS

5.08

3R(100)

151D241G04

5CLS-4R

151D241G04

—

CLS

5.08

4R(130)

151D241G05

5CLS-5R

151D241G05

—

CLS

5.08

5R(150)

151D241G06

5CLS-6R

151D241G06

—

CLS

5.08

6R(170)

151D251302

Obsolete—contact Eaton

—

15CLB-45C

—

—

—

151D251303

Obsolete—contact Eaton

—

15CLB-60C

—

—

—

151D253G01

4CX-18C

5978C62G01

—

CX

4.3

18C

151D253G02

4CX-25C

5978C62G02

—

CX

4.3

25C

151D253G03

4CX-35C

5978C62G03

—

CX

4.3

35C

151D253G04

4CX-45C

5978C66G01

—

CX

4.3

45C

151D253G05

4CX-50C

5978C66G02

—

CX

4.3

50C

V14-A2-36

Eaton
10 Digit
Style Number

Description

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

151D253G06

4CX-60C

151D253G06

151D253G07

4CX-75C

5978C66G04

—

CX

4.3

60C

—

CX

4.3

151D253G08

4CX-80C

75C

151D253G08

—

CX

4.3

151D253G26

80C

4CXI-60C

151D253G26

—

CX

4.3

60C

151D253G28

4CXI-80C

151D253G28

—

CX

4.3

80C

151D254G01

5CX-10C

151D254G11

—

CX

5.5

10C

151D254G02

5CX-12C

151D254G12

—

CX

5.5

12C

151D254G03

5CX-18C

5978C70G01

—

CX

5.5

18C

151D254G04

5CX-21C

151D254G04

—

CX

5.5

21C

151D254G05

5CX-25C

5978C70G03

—

CX

5.5

25C

151D254G06

5CX-35C

151D254G06

—

CX

5.5

35C

151D254G07

5CX-40C

5978C70G05

—

CX

5.5

40C

151D254G08

5CX-50C

5978C70G06

—

CX

5.5

50C

151D254G09

5CX-60C

151D254G09

—

CX

5.5

60C

151D254G11

5CX-10C

151D254G11

—

CX

5.5

10C

151D254G12

5CX-12C

151D254G12

—

CX

5.5

12C

151D254G24

5CXI-21C

151D254G24

—

CX

5.5

21C

151D254G26

5CXI-35C

151D254G26

—

CX

5.5

35C

151D254G29

5CXI_60C

151D254G29

—

CX

5.5

60C

151D254G31

5CXI-10C

151D254G31

—

CX

5.5

10C

151D254G32

5CXI-12C

151D254G32

—

CX

5.5

12C

151D255G01

8CX-3.5C

151D255G01

—

CX

8.3

3.5C

151D255G02

8CX-4C

151D255G02

—

CX

8.3

4C

151D255G03

8CX-7C

151D255G03

—

CX

8.3

7C

151D255G04

8CX-10C

151D255G11

—

CX

8.3

10C

151D255G05

8CX-12C

151D255G12

—

CX

8.3

12C

151D255G06

8CX-15C

151D255G06

—

CX

8.3

15C

151D255G07

8CX-18C

5978C72G01

—

CX

8.3

18C

151D255G08

8CX-25C

5978C72G03

—

CX

8.3

25C

151D255G09

8CX-35C

151D255G09

—

CX

8.3

35C

151D255G10

8CX-40C

5978C72G05

—

CX

8.3

40C

151D255G11

8CX-10C

151D255G11

—

CX

8.3

10C

151D255G12

8CX-12C

151D255G12

—

CX

8.3

12C

151D255G21

8CXI-3.5C

151D255G21

—

CX

8.3

3.5C

151D255G22

8CXI-4C

151D255G22

—

CX

8.3

4C

151D255G23

8CXI-7C

151D255G23

—

CX

8.3

7C

151D255G26

8CXI-15C

151D255G26

—

CX

8.3

15C

151D255G29

8CXI-35C

151D255G29

—

CX

8.3

35C

151D255G31

8CXI-10C

151D255G31

—

CX

8.3

10C

151D255G32

8CXI-12C

151D255G32

—

CX

8.3

12C

151D256G01

8CLS-15

151D256G01

—

CLS

8.3

15

151D256G02

8CLS-30

151D256G02

—

CLS

8.3

30

151D256G03

8CLS-60

151D256G03

—

CLS

8.3

60

151D256G04

8CLS-70

151D256G04

—

CLS

8.3

70

151D256G05

8CLS-90

151D256G05

—

CLS

8.3

90

151D256G06

8CLS-110

151D256G06

—

CLS

8.3

110

151D256G07

8CLS-125

151D256G07

—

CLS

8.3

125

151D256G11

8CLS-150

151D256G11

—

CLS

8.3

150

151D256G12

8CLS-200

151D256G12

—

CLS

8.3

200

151D256G13

8CLS-225

151D256G13

—

CLS

8.3

225

151D257G01

5CLS75-36R

151D257G01

—

CLS

5.08

36R(650)

151D257G02

5CLS75-32R

151D257G02

—

CLS

5.08

32R(600)

151D257G03

151D257G03

151D257G03

Bolt in quads

CLS

5.08

(1170)

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-A2-37

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

151D257G04

151D257G04

151D257G04

Bolt in quads

CLS

5.08

(1080)

151D257G05

5CLS75-24R

5CLS75-24R

—

CLS

5.08

24R(450)

151D883G01

15CX-3.5C

151D883G01

—

CX

15.5

3.5C

151D883G02

15CX-4C

151D883G02

—

CX

15.5

4C

151D883G03

15CX-7C

151D883G11

—

CX

15.5

7C

151D883G04

15CX-12C

151D883G12

—

CX

15.5

12C

151D883G06

15CX-15C

151D883G06

—

CX

15.5

15C

151D883G09

15CX-35C

151D883G09

—

CX

15.5

35C

151D883G11

15CX-10C

151D883G11

—

CX

15.5

10C

151D883G12

15CX-3C

151D883G12

—

CX

15.5

12C

151D883G21

15CXI-3.5C

151D883G21

—

CX

15.5

3.5C

151D883G22

15CXI-4C

151D883G22

—

CX

15.5

4C

151D883G23

15CXI-7C

151D883G23

—

CX

15.5

7C

151D883G26

15CXI-15C

151D883G26

—

CX

15.5

15C

151D883G29

15CXI-35C

151D883G29

—

CX

15.5

35C

151D883G31

15CXI-10C

151D883G31

—

CX

15.5

10C

151D883G32

15CXI-3C

151D883G32

—

CX

15.5

12C

151D884G01

5CX-GNM-G

151D884G01

—

CX

5.5

100

151D884G02

8CX-GNM-G

151D884G02

—

CX

8.3

40

151D884G03

15CX-GNM-G

151D884G03

—

CX

15.5

40

151D884G08

CX-NL

151D884G08

—

CX

—

100

151D885G01

5CX-GDM-G

151D885G01

—

CX

5.5

100

151D885G02

8CX-GDM-G

151D885G02

—

CX

8.3

40

151D885G03

15CX-GDM-G

151D885G03

—

CX

15.5

40

151D885G05

CX-DL

151D885G05

—

CX

—

100

151D885G06

CX-DF

151D885G06

—

CX

—

100

151D907G01

2CLE-PNM-D

9078A68G15

—

CLE

2.75

250

151D907G02

5CLE-PNM-D

9078A68G16

—

CLE

5.5

250

151D907G03

8CLE-PNM-D

9078A68G17

—

CLE

8.3

175

151D907G04

15CLE-PNM-D

9078A68G18

—

CLE

15.5

150

151D907G05

15CLE-HPNM-D

9078A68G19

—

CLE

15.5

150

151D907G07

Obsolete—contact Eaton

—

Obsolete 2.4 kV top rear con. mounting

CLE

—

—

151D907G08

Obsolete—contact Eaton

—

Obsolete 4.8 kV top rear con. mounting

CLE

—

—

151D907G09

Obsolete—contact Eaton

—

Obsolete 7.2 kV top rear con. mounting

CLE

—

—

151D907G10

Obsolete—contact Eaton

—

Obsolete 13.8 kV top rear con. mounting

CLE

—

—

151D907G11

Obsolete—contact Eaton

—

Obsolete 14.4 kV top rear con. mounting

CLE

—

—

151D907G13

Obsolete—contact Eaton

—

Obsolete 2.4 kV double rear con. mounting

CLE

—

—

151D907G14

Obsolete—contact Eaton

—

Obsolete 4.8 kV double rear con. mounting

CLE

—

—

151D907G15

Obsolete—contact Eaton

—

Obsolete 7.2 kV double rear con. mounting

CLE

—

—

151D907G16

Obsolete—contact Eaton

—

Obsolete 13.8 kV double rear con. mounting

CLE

—

—

151D907G17

Obsolete—contact Eaton

—

Obsolete 14.4 kV double rear con. mounting

CLE

—

—

151D907G19

Obsolete—contact Eaton

—

Obsolete 2.4 kV bottom rear con. mounting

CLE

—

—

151D907G20

Obsolete—contact Eaton

—

Obsolete 4.8 kV bottom rear con. mounting

CLE

—

—

151D907G21

Obsolete—contact Eaton

—

Obsolete 7.2 kV bottom rear con. mounting

CLE

—

—

151D907G22

Obsolete—contact Eaton

—

Obsolete 13.8 kV bottom rear con. mounting

CLE

—

—

151D907G23

Obsolete—contact Eaton

—

Obsolete 14.4 kV bottom rear con. mounting

CLE

—

—

151D909G01

2CLE-PNM-E

9078A68G20

—

CLE

2.75

450

151D909G02

5CLE-PNM-E

9078A68G21

—

CLE

5.5

450

151D909G03

8CLE-PNM-E

9078A68G22

—

CLE

8.3

350

151D909G04

15CLE-PNM-E

9078A68G23

—

CLE

15.5

300

151D909G05

15CLE-HPNM-E

9078A68G24

—

CLE

15.5

300

151D909G07

Obsolete—contact Eaton

—

Obsolete 2.4 kV top rear con. mounting

CLE

—

—

151D909G08

Obsolete—contact Eaton

—

Obsolete 4.8 kV top rear con. mounting

CLE

—

—

V14-A2-38

Eaton
10 Digit
Style Number

Description

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

151D909G09

Obsolete—contact Eaton

—

Obsolete 7.2 kV top rear con. mounting

CLE

—

—

151D909G10

Obsolete—contact Eaton

—

Obsolete 14.4 kV top rear con. mounting

CLE

—

—

151D909G13

Obsolete—contact Eaton

—

Obsolete 2.4 kV double rear con. mounting

CLE

—

—

151D909G14

Obsolete—contact Eaton

—

Obsolete 4.8 kV double rear con. mounting

CLE

—

—

151D909G15

Obsolete—contact Eaton

—

Obsolete 7.2 kV double rear con. mounting

CLE

—

—

151D909G16

Obsolete—contact Eaton

—

Obsolete 14.4 kV double rear con. mounting

CLE

—

—

151D909G19

Obsolete—contact Eaton

—

Obsolete 2.4 kV bottom rear con. mounting

CLE

—

—

151D909G20

Obsolete—contact Eaton

—

Obsolete 4.8 kV bottom rear con. mounting

CLE

—

—

151D909G21

Obsolete—contact Eaton

—

Obsolete 7.2 kV bottom rear con. mounting

CLE

—

—

151D909G22

Obsolete—contact Eaton

—

Obsolete 14.4 kV bottom rear con. mounting

CLE

—

—

151D911G06

5ACLS-9R

151D933G01

Tin plated ferrule

CLS

5.08

9R(200)

151D927G01

Contact EATON

—

Two—parallel 15CXN-60C

—

—

—

151D927G02

Contact EATON

—

Two—parallel 15CXN-75C

—

—

—

151D927G03

Contact EATON

—

Two—parallel 15CXN-85C

—

—

—

151D927G05

Contact EATON

—

Two—parallel 8CXN-150C

—

—

—

151D930G02

Obsolete—contact Eaton

—

15CLTX-15K

—

—

—

151D930G03

Obsolete—contact Eaton

—

8CLTX-15K

—

—

—

151D930G04

Obsolete—contact Eaton

—

8CLTX-40K

—

—

—

151D930G05

Obsolete—contact Eaton

—

15CLTX-40K

—

—

—

151D930G06

Obsolete—contact Eaton

—

23CLTX-15K

—

—

—

151D930G07

Obsolete—contact Eaton

—

8CLTX-25K

—

—

—

151D930G08

Obsolete—contact Eaton

—

15CLTX-25K

—

—

—

151D932G01

6DSL-C800

151D932G01

—

DSL

0.6

800

151D932G02

6DSL-C1000

151D932G02

—

DSL

0.6

1000

151D932G03

6DSL-C1200

151D932G03

—

DSL

0.6

1200

151D932G04

6DSL-C1600

151D932G04

—

DSL

0.6

1600

151D932G05

6DSL-C2000

151D932G05

—

DSL

0.6

2000

151D932G09

6DSL-D2500

151D932G09

—

DSL

0.6

2500

151D932G10

6DSL-D3000

151D932G10

—

DSL

0.6

3000

151D933G01

5ACLS-9R

151D933G01

—

CLS

5.08

9R(200)

151D933G02

5ACLS-12R

151D933G02

—

CLS

5.08

12R(230)

151D933G03

5ACLS-18R

151D933G03

—

CLS

5.08

18R(390)

151D933G04

5ACLS-24R

151D933G04

—

CLS

5.08

24R(450)

151D937G01

Obsolete—contact Eaton

151D937G01

2HCLE-25E sealed with hookeye

—

—

—

151D937G02

Obsolete—contact Eaton

151D937G02

2HCLE-30E sealed with hookeye

—

—

—

151D937G03

Obsolete—contact Eaton

151D937G03

2HCLE-50E sealed with hookeye

—

—

—

151D937G04

Obsolete—contact Eaton

151D937G04

2HCLE-65E sealed with hookeye

—

—

—

151D937G05

Obsolete—contact Eaton

151D937G05

2HCLE-80E sealed with hookeye

—

—

—

151D937G06

Obsolete—contact Eaton

151D937G06

2HCLE-100E sealed with hookeye

—

—

—

151D937G07

Obsolete—contact Eaton

151D937G07

2HCLE-125E sealed with hookeye

—

—

—

151D937G08

Obsolete—contact Eaton

151D937G08

2HCLE-150E sealed with hookeye

—

—

—

151D937G09

Obsolete—contact Eaton

151D937G09

2HCLE-200E sealed with hookeye

—

—

—

151D937G10

Obsolete—contact Eaton

151D937G10

2HCLE-225E sealed with hookeye

—

—

—

151D937G13

Obsolete—contact Eaton

151D937G13

2HCLE-250E sealed with hookeye

—

—

—

151D937G14

Obsolete—contact Eaton

151D937G14

2HCLE-300E sealed with hookeye

—

—

—

151D937G15

Obsolete—contact Eaton

151D937G15

2HCLE-350E sealed with hookeye

—

—

—

151D937G16

Obsolete—contact Eaton

151D937G16

2HCLE-365E sealed with hookeye

—

—

—

151D937G17

Obsolete—contact Eaton

151D937G17

2HCLE-400E sealed with hookeye

—

—

—

151D938G01

5AHLE-25E

5981C46G04

—

HLE

5.5

25E

151D938G02

5AHLE-30E

5981C46G05

—

HLE

5.5

30E

151D938G03

5AHLE-50E

5981C46G07

—

HLE

5.5

50E

151D938G04

5AHLE-65E

5981C46G08

—

HLE

5.5

65E

151D938G05

5AHLE-80E

5981C46G09

—

HLE

5.5

80E

Volume 14—Fuses

www.comoso.com

Type

Voltage
Rating
kV Max.

CA08100016E—August 2011 www.eaton.com

Current
Rating
Amperes

V14-A2-39

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

151D938G06

5AHLE100E

5981C46G10

151D938G07

5AHLE-125E

5981C46G11

—

HLE

5.5

100E

—

HLE

5.5

151D938G08

5AHLE-150E

125E

5981C46G12

—

HLE

5.5

151D938G09

150E

5AHLE-200E

5981C46G14

—

HLE

5.5

200E

151D938G10

Obsolete—contact Eaton

—

—

HLE

5.5

250E

151D939G01

5AHLE-250E

5981C46G15

—

HLE

5.5

250E

151D939G02

5AHLE-300E

5981C46G16

—

HLE

5.5

300E

151D939G03

5AHLE-400E

5981C46G18

—

HLE

5.5

400E

151D961G01

5CLS-9R

151D961G01

—

CLS

5.08

9R(200)

151D961G02

5CLS-12R

151D961G02

—

CLS

5.08

12R(230)

151D961G03

5CLS-18R

151D961G03

—

CLS

5.08

18R(390)

151D961G04

5CLS-24R

151D961G04

—

CLS

5.08

24R(450)

151D962G01

5HCLS-9R

151D962G01

—

CLS

5.08

9R(200)

151D962G02

5HCLS-12R

151D962G02

—

CLS

5.08

12R(230)

151D962G03

5HCLS-18R

151D962G03

—

CLS

5.08

18R(390)

151D962G04

5HCLS-24R

151D962G04

—

CLS

5.08

24R(450)

151D963G01

8ACLS-2R

151D963G01

—

CLS

8.3

2R(70)

151D963G02

8ACLS-3R

151D963G02

—

CLS

8.3

3R(100)

151D963G03

8ACLS-4R

151D963G03

—

CLS

8.3

4R(130)

151D963G04

8ACLS-5R

151D963G04

—

CLS

8.3

5R(150)

151D963G05

8ACLS-6R

151D963G05

—

CLS

8.3

6R(170)

151D963G06

7ACLS-9R

151D963G06

—

CLS

7.2

9R(200)

151D963G07

7ACLS-12R

151D963G07

—

CLS

7.2

12R(230)

151D963G10

7ACLS-18R

151D963G10

—

CLS

7.2

18R(390)

151D963G11

7ACLS-24R

151D963G11

—

CLS

7.2

24R(450)

151D967G01

Obsolete—contact Eaton

—

3.65 kV

CLS

—

—

151D967G02

Obsolete—contact Eaton

—

3.65 kV

CLS

—

—

151D967G03

Obsolete—contact Eaton

—

3.65 kV

CLS

—

—

151D967G04

Obsolete—contact Eaton

—

3.65 kV

CLS

—

—

151D967G05

Obsolete—contact Eaton

—

3.65 kV

CLS

—

—

151D967G06

Obsolete—contact Eaton

—

3.65 kV

CLS

—

—

151D967G07

Obsolete—contact Eaton

—

3.65 kV

CLS

—

—

151D967G08

Obsolete—contact Eaton

—

3.65 kV

CLS

—

—

151D967G09

Obsolete—contact Eaton

—

3.65 kV

CLS

—

—

151D967G10

Obsolete—contact Eaton

—

3.65 kV

CLS

—

—

151D978G01

5HLE-30E

5981C28G05

—

HLE

5.5

30E

151D978G02

5HLE-50E

5981C64G02

—

HLE

5.5

50E

151D978G03

5HLE-65E

5981C64G03

—

HLE

5.5

65E

151D978G04

5HLE-80E

5981C64G04

—

HLE

5.5

80E

151D978G05

5HLE-100E

5981C64G05

—

HLE

5.5

100E

151D978G06

5HLE-125E

5981C64G06

—

HLE

5.5

125E

151D978G07

5HLE-150E

5981C64G07

—

HLE

5.5

150E

151D978G08

5HLE-200E

5981C64G09

—

HLE

5.5

200E

151D978G09

Obsolete—contact Eaton

—

5SCLE-225E

—

—

—

151D978G11

5HLE-250E

5981C64G10

—

HLE

5.5

250E

151D978G12

5HLE-300E

5981C66G01

—

HLE

5.5

300E

151D978G13

5HLE-400E

5981C66G03

—

HLE

5.5

400E

151D979G01

5CLS70-600E

151D979G01

—

CLE

5.5

600E

151D979G02

5CLS70-750E

151D979G02

—

CLE

5.5

750E

18A7330G13

38DBA2-5E

18A7330G13

—

DBA2

38

5E

18A7330G14

38DBA2-7E

18A7330G14

—

DBA2

38

7E

18A7330G15

38DBA2-10E

18A7330G15

—

DBA2

38

10E

18A7330G16

38DBA2-15E

18A7330G16

—

DBA2

38

15E

V14-A2-40

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

18A7330G17

38DBA2-20E

18A7330G17

18A7330G18

38DBA2-25E

18A7330G18

—

DBA2

38

20E

—

DBA2

38

18A7330G19

38DBA2-30E

25E

18A7330G19

—

DBA2

38

18A7330G20

30E

38DBA2-40E

18A7330G20

—

DBA2

38

40E

18A7330G21

38DBA2-50E

18A7330G21

—

DBA2

38

50E

18A7330G22

38DBA2-65E

18A7330G22

—

DBA2

38

65E

18A7330G23

38DBA2-80E

18A7330G23

—

DBA2

38

80E

18A7330G24

38DBA2-100E

18A7330G24

—

DBA2

38

100E

18A7330G25

38DBA2-125E

18A7330G25

—

DBA2

38

125E

18A7330G26

38DBA2-150E

18A7330G26

—

DBA2

38

150E

18A7330G27

38DBA2-200E

18A7330G27

—

DBA2

38

200E

18A7330G33

48DBA2-5E

18A7330G33

—

DBA2

48

5E

18A7330G34

48DBA2-7E

18A7330G34

—

DBA2

48

7E

18A7330G35

48DBA2-10E

18A7330G35

—

DBA2

48

10E

18A7330G36

48DBA2-15E

18A7330G36

—

DBA2

48

15E

18A7330G37

48DBA2-20E

18A7330G37

—

DBA2

48

20E

18A7330G48

48DBA2-25E

18A7330G48

—

DBA2

48

25E

18A7330G39

48DBA2-30E

18A7330G39

—

DBA2

48

30E

18A7330G40

48DBA2-40E

18A7330G40

—

DBA2

48

40E

18A7330G41

48DBA2-50E

18A7330G41

—

DBA2

48

50E

18A7330G42

48DBA2-65E

18A7330G42

—

DBA2

48

65E

18A7330G43

48DBA2-80E

18A7330G43

—

DBA2

48

80E

18A7330G44

48DBA2-100E

18A7330G44

—

DBA2

48

100E

18A7330G45

48DBA2-125E

18A7330G45

—

DBA2

48

125E

18A7330G46

48DBA2-150E

18A7330G46

—

DBA2

48

150E

18A7330G47

48DBA2-200E

18A7330G47

—

DBA2

48

200E

18B1154G07

5LCLS-12R

676C546

225E 2.4 kV CLS-1 fuse

CLS

5.08

12R(230)

18B3115A10

Obsolete

—

2.4 kV CLE-1 mountings

—

—

—

2A98253G01

5ACLS-30

449D597G02

Asheville 3 pack

—

—

—

2A98253G02

5ACLS-2R

449D597G01

Asheville 3 pack

—

—

—

2A98253G03

5ACLS-3R

449D597G03

Asheville 3 pack

—

—

—

2A98253G04

5ACLS-4R

449D597G04

Asheville 3 pack

—

—

—

2A98253G05

5ACLS-5R

449D597G05

Asheville 3 pack

—

—

—

2A98253G06

5ACLS-6R

449D597G06

Asheville 3 pack

—

—

—

2A98253G07

5ACLS-9R

151D933G01

Asheville 3 pack

—

—

—

2A98253G08

5ACLS-12R

151D933G02

Asheville 3 pack

—

—

—

2A98253G09

5ACLS-18R

151D933G03

Asheville 3 pack

—

—

—

2A98253G10

5ACLS-24R

151D933G04

Asheville 3 pack

—

—

—

2A98253G11

5CLS70-24R

140D045G03

Asheville 3 pack

—

—

—

2A98253G12

5CLS70-36R

140D045G02

Asheville 3 pack

—

—

—

2A98253G13

5CLS70-44R

140D045G05

Asheville 3 pack

—

—

—

2A98253G21

8ACLS-2R

151D963G01

Asheville 3 pack

—

—

—

2A98253G22

8ACLS-3R

151D963G02

Asheville 3 pack

—

—

—

2A98253G23

8ACLS-4R

151D963G03

Asheville 3 pack

—

—

—

2A98253G24

8ACLS-5R

151D963G04

Asheville 3 pack

—

—

—

2A98253G25

8ACLS-6R

151D963G05

Asheville 3 pack

—

—

—

2A98253G26

7ACLS-9R

151D963G06

Asheville 3 pack

—

—

—

2A98253G27

7ACLS-12R

151D963G07

Asheville 3 pack

—

—

—

2A98253G28

7ACLS18R

151D963G10

Asheville 3 pack

—

—

—

2A98253G29

7ACLS-24R

151D963G11

Asheville 3 pack

—

—

—

2A98253G30

7CLS70-24R

5987C91G01

Asheville 3 pack

—

—

—

2A98253G31

7CLS70-36R

5987C91G02

Asheville 3 pack

—

—

—

2A98253G32

7CLS70-44R

5980C03G01

Asheville 3 pack

—

—

—

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-A2-41

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

2A98253G39

8ACLS-4L

5981C27G02

2A98253G40

CLS-700 DUMMY

591C172G01

Asheville 3 pack

—

—

—

Asheville 3 pack

—

—

2A98253G41

5AHLE-10E

—

5981C46G01

Asheville 3 pack

—

—

—

2A98253G42
2A98253G43

5AHLE-15E

5981C46G02

Asheville 3 pack

—

—

—

5AHLE-20E

5981C46G03

Asheville 3 pack

—

—

—

2A98253G44

5AHLE-25E

5981C46G04

Asheville 3 pack

—

—

—

2A98253G45

5AHLE-30E

5981C46G05

Asheville 3 pack

—

—

—

2A98253G46

5AHLE-40E

5981C46G06

Asheville 3 pack

—

—

—

2A98253G47

5AHLE-50E

5981C46G07

Asheville 3 pack

—

—

—

2A98253G48

5AHLE-65E

5981C46G08

Asheville 3 pack

—

—

—

2A98253G49

5AHLE-80E

5981C46G09

Asheville 3 pack

—

—

—

2A98253G50

5AHLE-100E

5981C46G10

Asheville 3 pack

—

—

—

2A98253G51

5AHLE-125E

5981C46G11

Asheville 3 pack

—

—

—

2A98253G52

5AHLE-150E

5981C46G12

Asheville 3 pack

—

—

—

2A98253G53

5AHLE-200E

5981C46G14

Asheville 3 pack

—

—

—

2A98253G54

5ACLE-225E

449D362G09

Asheville 3 pack

—

—

—

2A98253G55

5AHLE-250E

5981C46G15

Asheville 3 pack

—

—

—

2A98253G56

5AHLE-300E

5981C46G16

Asheville 3 pack

—

—

—

2A98253G57

5AHLE-350E

5981C46G17

Asheville 3 pack

—

—

—

2A98253G58

5AHLE-400E

5981C46G18

Asheville 3 pack

—

—

—

2A98253G59

5AHLE-450E

5981C46G19

Asheville 3 pack

—

—

—

2A98253G60

5CLS70-600E

151D979G01

Asheville 3 pack

—

—

—

2A98253G61

5CLS70-750E

151D979G02

Asheville 3 pack

—

—

—

2A98253G62

5BCLS-600E

9570D64G04

Asheville 3 pack

—

—

—

2A98253G63

5BCLS-750E

9570D64G05

Asheville 3 pack

—

—

—

2A98253G64

5CLE-1100E

9570D70G01

Asheville 3 pack

—

—

—

2A98253G65

5CLE-1350E

9570D70G02

Asheville 3 pack

—

—

—

2A98253G71

8AHLE-10E

5981C47G01

Asheville 3 pack

—

—

—

2A98253G72

8AHLE-15E

5981C47G02

Asheville 3 pack

—

—

—

2A98253G73

8AHLE-20E

5981C47G03

Asheville 3 pack

—

—

—

2A98253G74

8AHLE-25E

5981C47G04

Asheville 3 pack

—

—

—

2A98253G75

8AHLE-30E

5981C47G05

Asheville 3 pack

—

—

—

2A98253G76

8AHLE-40E

5981C47G06

Asheville 3 pack

—

—

—

2A98253G77

8AHLE-50E

5981C47G07

Asheville 3 pack

—

—

—

2A98253G78

8AHLE-65E

5981C47G08

Asheville 3 pack

—

—

—

2A98253G79

8AHLE-80E

5981C47G09

Asheville 3 pack

—

—

—

2A98253G80

8AHLE-100E

5981C47G10

Asheville 3 pack

—

—

—

2A98253G81

8AHLE-125E

5981C47G11

Asheville 3 pack

—

—

—

2A98253G82

8AHLE-150E

5981C47G12

Asheville 3 pack

—

—

—

2A98253G83

8AHLE-175E

5981C47G13

Asheville 3 pack

—

—

—

2A98253G84

8AHLE-200E

5981C47G14

Asheville 3 pack

—

—

—

2A98253G85

8AHLE-250E

5981C47G15

Asheville 3 pack

—

—

—

2A98253G86

8AHLE-300E

5981C47G16

Asheville 3 pack

—

—

—

204B956G01

Obsolete—contact Eaton

—

BAL mounting conversion kit

—

—

—

204B956G02

Obsolete—contact Eaton

—

BAL mounting conversion kit

—

—

—

204B956G03

Obsolete—contact Eaton

—

BAL mounting conversion kit

—

—

—

204B956G04

Obsolete—contact Eaton

—

BAL mounting conversion kit

—

—

—

204B956G05

Obsolete—contact Eaton

—

BAL mounting conversion kit

—

—

—

204B956G06

Obsolete—contact Eaton

—

BAL mounting conversion kit

—

—

—

208D480G02

2CLS-2R

591C812G02

—

CLS

2.54

2R(70)

208D480G04

2CLS-4R

591C812G04

—

CLS

2.54

4R(130)

208D480G06

2CLS-6R

591C812G06

—

CLS

2.54

6R(170)

208D480G07

2CLS-9R

591C812G07

—

CLS

2.54

9R(200)

V14-A2-42

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

208D480G08

2CLS-12R

591C812G08

208D481G01

2CLE-30E

449D797G02

—

CLS

2.54

12R(230)

—

CLE

2.75

208D481G03

2CLE-50E

30E

449D797G03

—

CLE

2.75

208D481G04

50E

2CLE-65E

449D797G04

—

CLE

2.75

65E

208D481G05

2CLE-80E

449D797G05

—

CLE

2.75

80E

208D481G06

2CLE-100E

449D797G06

—

CLE

2.75

100E

208D481G07

2CLE-125E

449D797G07

—

CLE

2.75

125E

208D481G08

2CLE-150E

449D797G08

—

CLE

2.75

150E

208D481G09

2CLE-200E

449D797G09

—

CLE

2.75

200E

208D502G01

15CLE-30E

5981C33G05

—

CLE

15.5

30E

208D502G02

15CLE-40E

5981C19G04

—

CLE

15.5

40E

208D502G03

15CLE-50E

5981C19G05

—

CLE

15.5

50E

208D502G04

15CLE-65E

5981C19G06

—

CLE

15.5

65E

208D502G05

15CLE-80E

5981C19G07

—

CLE

15.5

80E

208D502G06

15CLE-100E

5981C19G08

—

CLE

15.5

100E

21A5008A10

5CLPT-5E

677C453G01

—

CLPT

5.5

5E

22A6782G04

38DBA2-.5E

22A6782G04

—

DBA2

38

0.5

22A6782G05

48DBA2-.5E

22A6782G05

—

DBA2

48

0.5

22A6782G06

72DBA2-.5E

22A6782G06

—

DBA2

72

0.5

304C108G01

Obsolete—contact Eaton

—

BA-200 7.2 kV mounting

—

—

—

304C108G02

Obsolete—contact Eaton

—

BA-200 14.4 kV mounting

—

—

—

304C108G03

Obsolete—contact Eaton

—

BA-200 23 kV mounting

—

—

—

304C108G04

Obsolete—contact Eaton

—

BA-200 34.5 kV mounting

—

—

—

304C108G05

Obsolete—contact Eaton

—

BA-200 7.2/14.4 kV mounting

—

—

—

304C108G06

Obsolete—contact Eaton

—

BA-200 14.4/23 kV mounting

—

—

—

304C108G07

Obsolete—contact Eaton

—

BA-200 23/34.5 kV mounting

—

—

—

304C108G08

Obsolete—contact Eaton

—

BA-200 34.5/46 kV mounting

—

—

—

304C109G01

Obsolete—contact Eaton

—

BA-400 7.2 kV mounting

—

—

—

304C109G02

Obsolete—contact Eaton

—

BA-400 14.4 kV mounting

—

—

—

304C109G03

Obsolete—contact Eaton

—

BA-400 23 kV mounting

—

—

—

304C109G04

Obsolete—contact Eaton

—

BA-400 34.5 kV mounting

—

—

—

304C109G05

Obsolete—contact Eaton

—

BA-400 7.2/14.4 kV mounting

—

—

—

304C109G06

Obsolete—contact Eaton

—

BA-400 14.4/23 kV mounting

—

—

—

304C109G07

Obsolete—contact Eaton

—

BA-400 23/34.5 kV mounting

—

—

—

304C109G08

Obsolete—contact Eaton

—

BA-400 34.5/46 kV mounting

—

—

—

304C337G08

25CLPT-1E

677C452G09

—

CLPT

25.5

1

304C356G01

Obsolete—contact Eaton

—

BA-400 7.2 kV mounting

—

—

—

304C356G02

Obsolete—contact Eaton

—

BA-400 14.4 kV mounting

—

—

—

304C356G03

Obsolete—contact Eaton

—

BA-400 23 kV mounting

—

—

—

304C356G04

Obsolete—contact Eaton

—

BA-400 34.5 kV mounting

—

—

—

304C356G05

Obsolete—contact Eaton

—

BA-400 7.2/14.4 kV mounting

—

—

—

304C356G06

Obsolete—contact Eaton

—

BA-400 14.4/23 kV mounting

—

—

—

304C356G07

Obsolete—contact Eaton

—

BA-400 23/34.5 kV mounting

—

—

—

304C356G08

Obsolete—contact Eaton

—

BA-400 34.5/46 kV mounting

—

—

—

304C437G01

Obsolete—contact Eaton

—

BA-200 7.2 kV mounting

—

—

—

304C437G02

Obsolete—contact Eaton

—

BA-200 14.4 kV mounting

—

—

—

304C437G03

Obsolete—contact Eaton

—

BA-200 23 kV mounting

—

—

—

304C437G04

Obsolete—contact Eaton

—

BA-200 34.5 kV mounting

—

—

—

304C438G01

Obsolete—contact Eaton

—

BA-200 7.2 kV mounting

—

—

—

304C438G02

Obsolete—contact Eaton

—

BA-200 14.4 kV mounting

—

—

—

304C438G03

Obsolete—contact Eaton

—

BA-200 23 kV mounting

—

—

—

304C438G04

Obsolete—contact Eaton

—

BA-200 34.5 kV mounting

—

—

—

304C444G01

Obsolete—contact Eaton

—

BA-200 7.2 kV mounting

—

—

—

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-A2-43

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

304C444G02

Obsolete—contact Eaton

—

304C444G03

Obsolete—contact Eaton

—

BA-200 14.4 kV mounting

—

—

—

BA-200 23 kV mounting

—

—

304C444G04

Obsolete—contact Eaton

—

—

BA-200 34.5 kV mounting

—

—

—

304C463G01
304C463G02

2CLS-18R

591C813G01

—

CLS

2.54

18R(390)

2CLS-24R

591C813G02

—

CLS

2.54

24R

304C463G03

5LCLS-24R

304C463G03

—

CLS

5.08

18R(390)

304C463G04

5LCLS-18R

304C463G04

—

CLS

5.08

24R

308C310G10

CLE-NL-E

9078A67G04

—

CLE

—

450

308C427A02

2CLE-PNM-D

9078A68G15

—

CLE

2.75

250

308C427A03

5CLE-PNM-D

9078A68G16

—

CLE

5.5

250

308C427A04

8CLE-PNM-D

9078A68G17

—

CLE

8.3

175

308C427A06

15CLE-PNM-D

9078A68G18

—

CLE

15.5

150

308C427A07

15CLE-HPNM-D

9078A68G19

—

CLE

15.5

150

308C427A11

Obsolete—contact Eaton

—

Rear connected non-disconnect CLE mountings

—

—

—

308C427A12

Obsolete—contact Eaton

—

Rear connected non-disconnect CLE mountings

—

—

—

308C427A13

Obsolete—contact Eaton

—

Rear connected non-disconnect CLE mountings

—

—

—

308C427A15

Obsolete—contact Eaton

—

Rear connected non-disconnect CLE mountings

—

—

—

308C427A16

Obsolete—contact Eaton

—

Rear connected non-disconnect CLE mountings

—

—

—

308C427A20

Obsolete—contact Eaton

—

Rear connected non-disconnect CLE mountings

—

—

—

308C427A21

Obsolete—contact Eaton

—

Rear connected non-disconnect CLE mountings

—

—

—

308C427A22

Obsolete—contact Eaton

—

Rear connected non-disconnect CLE mountings

—

—

—

308C427A24

Obsolete—contact Eaton

—

Rear connected non-disconnect CLE mountings

—

—

—

308C427A25

Obsolete

—

Rear connected non-disconnect CLE mountings

—

—

—

309C024G03

RBA2-FLTR

309C024G03

(3 pack)

RBA2

—

200

309C024G04

RBA4-FLTR

309C024G04

(3 pack)

RBA4

—

400

309C024G05

RBA2-FLTR-1

309C024G05

(1 pack)

RBA2

—

200

309C273G02

Obsolete—contact Eaton

—

BA-200 13.8 kV dummy fuse

—

—

—

309C548G01

8RDB2-SHNT

309C548G01

—

RDB2

8.3

200

309C548G02

15RDB2-SHNT

309C548G02

—

RDB2

15.5

200

309C548G03

25RDB2-SHNT

309C548G03

—

RDB2

25.5

200

309C548G04

38RDB2-SHNT

309C548G04

—

RDB2

38

200

309C548G05

8RBA2-SHNT

309C548G05

—

RBA2

8.3

200

309C548G06

15RBA2-SHNT

309C548G06

—

RBA2

15.5

200

309C548G07

25RBA2-SHNT

309C548G07

—

RBA2

25.5

200

309C548G08

38RBA2-SHNT

309C548G08

—

RBA2

38

200

309C548G09

8RBA2-ISHNT

309C548G09

—

RBA2

8.3

200

309C548G10

15RBA2-ISHNT

309C548G10

—

RBA2

15.5

200

309C548G11

25RBA2-ISHNT

309C548G11

—

RBA2

25.5

200

309C548G12

38RBA2-ISHNT

309C548G12

—

RBA2

38

200

309C558G01

8RBA2-DH

309C558G01

—

RBA2

8.3

200

309C558G02

15RBA2-DH

309C558G02

—

RBA2

15.5

200

309C558G03

25RBA2-DH

309C558G03

—

RBA2

25.5

200

309C558G04

38RBA2-DH

309C558G04

—

RBA2

38

200

309C558G05

8RDB2-DH

309C558G05

—

RDB2

8.3

200

309C558G06

15RDB2-DH

309C558G06

—

RDB2

15.5

200

309C558G07

25RDB2-DH

309C558G07

—

RDB2

25.5

200

309C558G08

38RDB2-DH

309C558G08

—

RDB2

38

200

309C558G09

8RBA2-LBDH

309C558G09

—

RBA2

8.3

200

309C558G10

15RBA2-LBDH

309C558G10

—

RBA2

15.5

200

309C558G11

25RBA2-LBDH

309C558G11

—

RBA2

25.5

200

309C660G02

2HCLS-2R

591C155G02

—

CLS

2.75

2R(70)

309C660G03

2HCLS-3R

591C155G03

—

CLS

2.75

B

309C660G04

2HCLS-4R

591C155G04

—

CLS

2.75

4R(130)

V14-A2-44

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

309C660G05

2HCLS-5R

591C155G05

309C660G06

2HCLS-6R

591C155G06

—

CLS

2.75

5R(150)

—

CLS

2.75

309C660G09

2HCLS-9R

6R(170)

591C155G07

—

CLS

2.75

309C660G12

9R(200)

2HCLS-12R

591C155G08

—

CLS

2.75

12R(230)

309C660G15

Obsolete—contact Eaton

—

Hermetically sealed 5LCLS-2R fuse

—

—

—

309C660G16

Obsolete—contact Eaton

—

Hermetically sealed 5LCLS-2R fuse

—

—

—

309C660G17

Obsolete—contact Eaton

—

Hermetically sealed 5LCLS-2R fuse

—

—

—

309C660G18

Obsolete—contact Eaton

—

Hermetically sealed 5LCLS-2R fuse

—

—

—

309C660G19

Obsolete—contact Eaton

—

Hermetically sealed 5LCLS-2R fuse

—

—

—

309C660G22

Obsolete—contact Eaton

—

Hermetically sealed 5LCLS-2R fuse

—

—

—

309C660G25

Obsolete—contact Eaton

—

Hermetically sealed 5LCLS-2R fuse

—

—

—

309C797G01

8RBA4-DH

309C797G01

—

RBA4

8.3

400

309C797G02

15RBA4-DH

309C797G02

—

RBA4

15.5

400

309C797G03

25RBA4-DH

309C797G03

—

RBA4

25.5

300

309C797G04

38RBA4-DH

309C797G04

—

RBA4

38

300

309C797G05

8RBA4-LBDH

309C797G05

—

RBA4

8.3

400

309C797G06

15RBA4-LBDH

309C797G06

—

RBA4

15.5

400

309C797G07

25RBA4-LBDH

309C797G07

—

RBA4

25.5

300

30A6178G01

Obsolete—contact Eaton

—

BA-800 7.2 kV mounting

—

—

—

30A6178G02

Obsolete—contact Eaton

—

BA-800 14.4 kV mounting

—

—

—

30A6178G03

Obsolete—contact Eaton

—

BA-800 723 kV mounting

—

—

—

30A6178G04

Obsolete—contact Eaton

—

BA-800 34.5 kV mounting

—

—

—

30A6178G05

Obsolete—contact Eaton

—

BA-800 live parts

—

—

—

30A6178G06

Obsolete—contact Eaton

—

BA-800 7.2 kV mounting

—

—

—

30A6178G07

Obsolete—contact Eaton

—

BA-800 14.4 kV mounting

—

—

—

30A6178G08

Obsolete—contact Eaton

—

BA-800 723 kV mounting

—

—

—

30A6178G09

Obsolete—contact Eaton

—

BA-800 34.5 kV mounting

—

—

—

310C095G01

Obsolete—contact Eaton

—

3 in dia. 2.4 kV 25E fuse

—

—

—

310C095G02

2CLE-50E

449D797G03

—

CLE

2.75

50E

310C095G03

2CLE-65E

449D797G04

—

CLE

2.75

65E

310C095G04

2CLE-80E

449D797G05

—

CLE

2.75

80E

310C095G05

2CLE-100E

449D797G06

—

CLE

2.75

100E

310C095G06

2CLE-125E

449D797G07

—

CLE

2.75

125E

310C095G07

2CLE-150E

449D797G08

—

CLE

2.75

150E

310C095G08

2CLE-200E

449D797G09

—

CLE

2.75

200E

310C095G10

2CLE-30E

449D797G02

—

CLE

2.75

30E

310C095G12

5CLE-50E

5981C65G02

—

CLE

5.5

50E

310C095G13

5CLE-65E

5981C65G03

—

CLE

5.5

65E

310C095G14

5CLE-80E

5981C65G04

—

CLE

5.5

80E

310C095G15

5CLE100E

5981C65G05

—

CLE

5.5

100E

310C095G16

5CLE-125E

5981C65G06

—

CLE

5.5

125E

310C095G17

5CLE-150E

5981C65G07

—

CLE

5.5

150E

310C095G18

5CLE-200E

5981C65G09

—

CLE

5.5

200E

310C095G19

Obsolete—contact Eaton

—

5CLE1-225E

—

—

—

310C095G20

5CLE-30E

5981C28G03

—

CLE

5.5

30E

310C095G21

5CLE-40E

5981C65G01

—

CLE

5.5

40E

—

8BA4-NH

310C196G01

—

BA4

8.3

400

—

15BA4-NH

310C196G02

—

BA4

15.5

400

310C131G01

8RDB4-DH

310C131G01

—

RDB4

8.3

400

310C131G02

15RDB4-DH

310C131G02

—

RDB4

15.5

400

310C131G03

25RDB4-DH

310C131G03

—

RDB4

25.5

300

310C131G04

38RDB4-DH

310C131G04

—

RDB4

38

300

310C132G01

RBA4-FLTR

309C024G04

—

RBA4

—

400

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-A2-45

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

310C191A01

Obsolete—contact Eaton

—

310C191A02

Obsolete—contact Eaton

—

BA-400 live parts

—

—

—

BA-400 live parts—rear connected

—

—

310C191A03

Obsolete—contact Eaton

—

—

BA-400 live parts—rear connected

—

—

310C191A04

—

Obsolete—contact Eaton

—

BA-400 live parts—rear connected

—

—

—

310C192G01

Obsolete—contact Eaton

—

BA-400S fuse holder

—

—

—

310C192G02

Obsolete—contact Eaton

—

BA-400S fuse holder

—

—

—

310C192G03

Obsolete—contact Eaton

—

BA-400S fuse holder

—

—

—

310C192G04

Obsolete—contact Eaton

—

BA-400S fuse holder

—

—

—

310C196G01

8BA4-NH

310C196G01

—

BA4

8.3

400

310C196G02

15BA4-NH

310C196G02

—

BA4

15.5

400

310C196G03

Obsolete—contact Eaton

—

—

—

—

—

310C196G04

Obsolete—contact Eaton

—

—

—

—

—

310C197G03

RBA2-COND

310C197G03

(3 pack)

RBA2

—

200

310C197G04

RBA4-COND

310C197G04

(3 pack)

RBA4

—

400

310C197G05

RBA2-COND

310C197G05

(1 pack)

RBA2

—

200

310C197G06

RBA4-COND

310C197G06

(1 pack)

RBA4

—

400

310C198G01

8BA2-NH

310C198G01

—

BA2

8.3

200

310C198G02

15BA2-NH

310C198G02

—

BA2

15.5

200

310C198G03

Obsolete—contact Eaton

—

—

—

—

—

310C198G04

Obsolete—contact Eaton

—

—

—

—

—

310C392G01

Obsolete—contact Eaton

—

Special BA-400 fuse holder

—

—

—

310C392G02

Obsolete—contact Eaton

—

Special BA-400 fuse holder

—

—

—

310C658G02

5LCLS-2R

676C546G15

—

CLS

5.08

2R(70)

310C658G03

5LCLS-3R

676C546G16

—

CLS

5.08

3R(100)

310C658G04

5LCLS-4R

676C546G17

—

CLS

5.08

4R(130)

310C658G05

5LCLS-5R

676C546G18

—

CLS

5.08

5R(150)

310C658G06

5LCLS-6R

676C546G19

—

CLS

5.08

6R(170)

310C658G09

5LCLS-9R

676C546G22

—

CLS

5.08

9R(200)

310C658G12

5LCLS-12R

676C546G25

—

CLS

5.08

12R(230)

310C660G01

2CLS-18R

591C813G01

—

CLS

2.54

18R(390)

310C660G02

2CLS-24R

591C813G02

—

CLS

2.54

24R(450)

310C660G03

Obsolete—contact Eaton

—

Hermetically sealed 5LCLS-18R

—

—

—

310C660G04

Obsolete—contact Eaton

—

Hermetically sealed 5LCLS-24R

—

—

—

310C905G01

2CLE-250E

449D797G13

—

CLE

2.75

250E

310C905G03

2CLE-300E

449D797G14

—

CLE

2.75

300E

310C905G04

2CLE-350X

449D797G15

—

CLE

2.75

350X

310C905G06

2CLE-400X

449D797G17

—

CLE

2.75

400X

310C905G09

5CLE-250E

5981C65G10

—

CLE

5.5

250E

310C905G11

5CLE-300E

5981C67G01

—

CLE

5.5

300E

310C905G12

5CLE-350E

5981C67G02

—

CLE

5.5

350E

310C905G13

Obsolete—contact Eaton

—

5CLE2-365X

—

—

—

310C905G14

5CLE-400E

5981C67G03

—

CLE

5.5

400E

336C490G01

2CLS-12R

591C812G08

—

CLS

2.54

12R(230)

337A770G01

2CLS-2R

591C812G02

—

CLS

2.54

2R(70)

337A771G01

2CLS-4R

591C812G04

—

CLS

2.54

4R(130)

337A772G01

2CLS-6R

591C812G06

—

CLS

2.54

6R(170)

337A773G01

2CLS-9R

591C812G07

—

CLS

2.54

9R(200)

337A774G01

2CLS-12R

591C812G08

—

CLS

2.54

12R(230)

337A775G01

5CLS-2R

151D241G02

—

CLS

5.08

2R(70)

337A776G01

5CLS-4R

151D241G04

—

CLS

5.08

4R(130)

337A777G01

5CLS-6R

151D241G06

—

CLS

5.08

6R(170)

337A778G01

5CLS-9R

151D961G01

—

CLS

5.08

9R(200)

337A779G01

5CLS-12R

151D961G02

—

CLS

5.08

12R(230)

V14-A2-46

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

343D316A34

Obsolete—contact Eaton

—

343D316A35

Obsolete—contact Eaton

—

25BT-15E

—

—

—

25BT-20E

—

—

343D316A36

Obsolete—contact Eaton

—

—

25BT-25E

—

—

343D316A37

—

Obsolete—contact Eaton

—

25BT-30E

—

—

—

343D316A38

Obsolete—contact Eaton

—

25BT-40E

—

—

—

343D316A39

Obsolete—contact Eaton

—

25BT-50E

—

—

—

343D316A40

Obsolete—contact Eaton

—

25BT-65E

—

—

—

343D316A41

Obsolete—contact Eaton

—

25BT-80E

—

—

—

343D316A42

Obsolete—contact Eaton

—

25BT-100E

—

—

—

343D316A43

Obsolete—contact Eaton

—

25BT-125E

—

—

—

343D316A44

Obsolete—contact Eaton

—

25BT-150E

—

—

—

343D316A45

Obsolete—contact Eaton

—

25BT-200E

—

—

—

366C453G01

RBA2-FLTR

309C024G03

(3 pack)

RBA2

—

200

366C453G02

RBA4-FLTR

309C024G04

(3 pack)

RBA4

—

400

366C474G01

2CLS-2R

591C812G02

—

CLS

2.54

2R(70)

366C474G02

2CLS-4R

591C812G04

—

CLS

2.54

4R(130)

366C474G03

2CLS-6R

591C812G06

—

CLS

2.54

6R(170)

366C474G04

2CLS-9R

591C812G07

—

CLS

2.54

9R(200)

366C474G05

2CLS-12R

591C812G08

—

CLS

2.54

12R(230)

366C474G07

5LCLS-2R

676C546G15

—

CLS

5.08

2R(70)

366C474G08

5LCLS-4R

676C546G17

—

CLS

5.08

4R(130)

366C474G09

5LCLS-6R

676C546G19

—

CLS

5.08

6R(170)

366C474G10

5LCLS-9R

676C546G22

—

CLS

5.08

9R(200)

366C474G11

5LCLS-12R

676C546G25

—

CLS

5.08

12R(230)

366C474G13

5LCLS-2R

676C546G15

—

CLS

5.08

2R(70)

366C474G14

5LCLS-4R

676C546G17

—

CLS

5.08

4R(130)

366C474G15

5LCLS-6R

676C546G19

—

CLS

5.08

6R(170)

366C474G16

5LCLS-9R

676C546G22

—

CLS

5.08

9R(200)

366C474G17

5LCLS-12R

676C546G25

—

CLS

5.08

12R(230)

366C490G01

2CLS-12R

591C812G08

—

CLS

2.54

12R(230)

366C490G02

5CLS-12R

676C546G25

—

CLS

5.08

12R(230)

366C490G03

2CLS-12R

591C812G08

—

CLS

2.54

12R(230)

366C490G04

5CLS-12R

676C546G25

—

CLS

5.08

12R(230)

366C569G02

Obsolete

—

BA-200 50E fuse

—

—

—

366C569G03

Obsolete

—

BA-200 65E fuse

—

—

—

366C569G04

Obsolete

—

BA-200 80E fuse

—

—

—

366C569G05

Obsolete

—

BA-200 100E fuse

—

—

—

366C569G06

Obsolete

—

BA-200 125E fuse

—

—

—

366C569G07

Obsolete

—

BA-200 150E fuse

—

—

—

366C569G08

Obsolete

—

BA-200 200E fuse

—

—

—

390B923G01

2CLE-50E

449D797G03

—

CLE

2.75

50E

390B924G01

2CLE-65E

449D797G04

—

CLE

2.75

65E

390B925G01

2CLE-80E

449D797G05

—

CLE

2.75

80E

390B926G01

2CLE100E

449D797G06

—

CLE

2.75

100E

390B927G01

2CLE-125E

449D797G07

—

CLE

2.75

125E

390B928G01

2CLE-150E

449D797G08

—

CLE

2.75

150E

390B929G01

2CLE-200E

449D797G09

—

CLE

2.75

200E

390B932G01

5CLE-50E

5981C65G02

—

CLE

5.5

50E

390B932G02

5CLE-65E

5981C65G03

—

CLE

5.5

65E

390B934G03

5CLE-80E

5981C65G04

—

CLE

5.5

80E

390B935G01

5CLE100E

5981C65G05

—

CLE

5.5

100E

390B936G01

5CLE-125E

5981C65G06

—

CLE

5.5

125E

390B937G01

5CLE-150E

5981C65G07

—

CLE

5.5

150E

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-A2-47

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

390B938G01

5CLE-200E

5981C65G09

390B941G01

5CLE-50E

5981C65G02

—

CLE

5.5

200E

—

CLE

5.5

390B942G01

5CLE-65E

50E

5981C65G03

—

CLE

5.5

391B247G01

65E

5CLE-25E

678C240G05

—

CLE

5.5

25E

391B271G01

2CLE-15E

678C240G01

—

CLE

2.75

15E

391B272G01

2CLE-25E

678C240G03

—

CLE

2.75

25E

391B273G01

5CLE-15E

678C240G04

—

CLE

5.5

15E

391B275G01

15CLE-25E

678C240G12

—

CLE

15.5

25E

414D224G01

Obsolete—contact Eaton

—

BA-200 mounting—4.8 kV

—

—

—

414D224G02

Obsolete—contact Eaton

—

BA-200 mounting—7.2 kV

—

—

—

414D224G03

Obsolete—contact Eaton

—

BA-200 mounting—13.8 kV

—

—

—

414D224G04

Obsolete—contact Eaton

—

BA-200 mounting—14.4 kV

—

—

—

414D224G05

Obsolete—contact Eaton

—

BA-200 mounting—23 kV

—

—

—

414D224G06

Obsolete—contact Eaton

—

BA-200 mounting—34.5 kV

—

—

—

414D224G07

Obsolete—contact Eaton

—

BA-200 mounting—4.8 kV

—

—

—

414D224G08

Obsolete—contact Eaton

—

BA-200 mounting—7.2 kV

—

—

—

414D224G09

Obsolete—contact Eaton

—

BA-200 mounting—13.8 kV

—

—

—

414D224G10

Obsolete—contact Eaton

—

BA-200 mounting—14.4 kV

—

—

—

414D224G11

Obsolete—contact Eaton

—

BA-200 mounting—23 kV

—

—

—

414D224G12

Obsolete—contact Eaton

—

BA-200 mounting—34.5 kV

—

—

—

414D224G13

Obsolete—contact Eaton

—

BA-200 mounting—4.8 kV

—

—

—

414D224G14

Obsolete—contact Eaton

—

BA-200 mounting—7.2 kV

—

—

—

414D224G15

Obsolete—contact Eaton

—

BA-200 mounting—13.8 kV

—

—

—

414D224G16

Obsolete—contact Eaton

—

BA-200 mounting—14.4 kV

—

—

—

414D224G17

Obsolete—contact Eaton

—

BA-200 mounting—23 kV

—

—

—

414D224G18

Obsolete—contact Eaton

—

BA-200 mounting—34.5 kV

—

—

—

414D225G01

Obsolete—contact Eaton

—

BA-200 mounting—4.8 kV

—

—

—

414D225G02

Obsolete—contact Eaton

—

BA-200 mounting—7.2 kV

—

—

—

414D225G03

Obsolete—contact Eaton

—

BA-200 mounting—13.8 kV

—

—

—

414D225G04

Obsolete—contact Eaton

—

BA-200 mounting—14.4 kV

—

—

—

414D225G05

Obsolete—contact Eaton

—

BA-200 mounting—23 kV

—

—

—

414D225G06

Obsolete—contact Eaton

—

BA-200 mounting—34.5 kV

—

—

—

414D225G07

Obsolete—contact Eaton

—

BA-200 mounting—4.8 kV

—

—

—

414D225G08

Obsolete—contact Eaton

—

BA-200 mounting—7.2 kV

—

—

—

414D225G09

Obsolete—contact Eaton

—

BA-200 mounting—13.8 kV

—

—

—

414D225G10

Obsolete—contact Eaton

—

BA-200 mounting—14.4 kV

—

—

—

414D225G11

Obsolete—contact Eaton

—

BA-200 mounting—4.8 kV

—

—

—

414D225G12

Obsolete—contact Eaton

—

BA-200 mounting—7.2 kV

—

—

—

414D225G13

Obsolete—contact Eaton

—

BA-200 mounting—13.8 kV

—

—

—

414D225G14

Obsolete—contact Eaton

—

BA-200 mounting—14.4 kV

—

—

—

414D225G15

Obsolete—contact Eaton

—

BA-200 mounting—4.8 kV

—

—

—

414D225G16

Obsolete—contact Eaton

—

BA-200 mounting—7.2 kV

—

—

—

414D225G17

Obsolete—contact Eaton

—

BA-200 mounting—13.8 kV

—

—

—

414D225G18

Obsolete—contact Eaton

—

BA-200 mounting—14.4 kV

—

—

—

414D226G01

Obsolete—contact Eaton

—

BA-400 mounting—4.8 kV

—

—

—

414D226G02

Obsolete—contact Eaton

—

BA-400 mounting—7.2 kV

—

—

—

414D226G03

Obsolete—contact Eaton

—

BA-400 mounting—13.8 kV

—

—

—

414D226G04

Obsolete—contact Eaton

—

BA-400 mounting—14.4 kV

—

—

—

414D226G05

Obsolete—contact Eaton

—

BA-400 mounting—23 kV

—

—

—

414D226G06

Obsolete—contact Eaton

—

BA-400 mounting—34.5 kV

—

—

—

414D226G07

Obsolete—contact Eaton

—

BA-400 mounting—4.8 kV

—

—

—

414D226G08

Obsolete—contact Eaton

—

BA-400 mounting—7.2 kV

—

—

—

414D226G09

Obsolete—contact Eaton

—

BA-400 mounting—13.8 kV

—

—

—

V14-A2-48

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

414D226G10

Obsolete—contact Eaton

—

414D226G11

Obsolete—contact Eaton

—

BA-400 mounting—14.4 kV

—

—

—

BA-400 mounting—23 kV

—

—

414D226G12

Obsolete—contact Eaton

—

—

BA-400 mounting—4.8 kV

—

—

—

414D226G13
414D226G14

Obsolete—contact Eaton

—

BA-400 mounting—7.2 kV

—

—

—

Obsolete—contact Eaton

—

BA-400 mounting—13.8 kV

—

—

—

414D226G15

Obsolete—contact Eaton

—

BA-400 mounting—14.4 kV

—

—

—

414D226G16

Obsolete—contact Eaton

—

BA-400 mounting—23 kV

—

—

—

414D226G17

Obsolete—contact Eaton

—

BA-400 mounting—4.8 kV

—

—

—

414D226G18

Obsolete—contact Eaton

—

BA-400 mounting—7.2 kV

—

—

—

414D226G19

Obsolete—contact Eaton

—

BA-400 mounting—13.8 kV

—

—

—

414D226G20

Obsolete—contact Eaton

—

BA-400 mounting—14.4 kV

—

—

—

414D226G21

Obsolete—contact Eaton

—

BA-400 mounting—23 kV

—

—

—

414D227G01

Obsolete—contact Eaton

—

BA-400 mounting—4.8 kV

—

—

—

414D227G02

Obsolete—contact Eaton

—

BA-400 mounting—7.2 kV

—

—

—

414D227G03

Obsolete—contact Eaton

—

BA-400 mounting—13.8 kV

—

—

—

414D227G04

Obsolete—contact Eaton

—

BA-400 mounting—14.4 kV

—

—

—

414D227G05

Obsolete—contact Eaton

—

BA-400 mounting—23 kV

—

—

—

414D227G06

Obsolete—contact Eaton

—

BA-400 mounting—34.5 kV

—

—

—

414D227G07

Obsolete—contact Eaton

—

BA-400 mounting—4.8 kV

—

—

—

414D227G08

Obsolete—contact Eaton

—

BA-400 mounting—7.2 kV

—

—

—

414D227G09

Obsolete—contact Eaton

—

BA-400 mounting—13.8 kV

—

—

—

414D227G10

Obsolete—contact Eaton

—

BA-400 mounting—14.4 kV

—

—

—

414D227G11

Obsolete—contact Eaton

—

BA-400 mounting—23 kV

—

—

—

414D227G12

Obsolete—contact Eaton

—

BA-400 mounting—4.8 kV

—

—

—

414D227G13

Obsolete—contact Eaton

—

BA-400 mounting—7.2 kV

—

—

—

414D227G14

Obsolete—contact Eaton

—

BA-400 mounting—13.8 kV

—

—

—

414D227G15

Obsolete—contact Eaton

—

BA-400 mounting—14.4 kV

—

—

—

414D227G16

Obsolete—contact Eaton

—

BA-400 mounting—23 kV

—

—

—

414D227G17

Obsolete—contact Eaton

—

BA-400 mounting—4.8 kV

—

—

—

414D227G18

Obsolete—contact Eaton

—

BA-400 mounting—7.2 kV

—

—

—

414D227G19

Obsolete—contact Eaton

—

BA-400 mounting—13.8 kV

—

—

—

414D227G20

Obsolete—contact Eaton

—

BA-400 mounting—14.4 kV

—

—

—

414D227G21

Obsolete—contact Eaton

—

BA-400 mounting—23 kV

—

—

—

418D565G31

5CLE-200E

5981G65G09

—

CLE

5.5

200E

421D701G17

8CLE-80E

5981C17G06

—

CLE

8.3

80E

421D701G19

8CLE-100E

5981C17G07

—

CLE

8.3

100E

421D701G25

15CLE-80E

5981C19G07

—

CLE

15.5

80E

421D701G26

15CLE-100E

5981C19G08

—

CLE

15.5

100E

422D324G01

Obsolete—contact Eaton

—

BA-800 mounting—4.8 kV

—

—

—

422D324G02

Obsolete—contact Eaton

—

BA-800 mounting—4.8 kV

—

—

—

422D324G03

Obsolete—contact Eaton

—

BA-800 mounting—4.8 kV

—

—

—

422D324G04

Obsolete—contact Eaton

—

BA-800 mounting—4.8 kV

—

—

—

422D324G05

Obsolete—contact Eaton

—

BA-800 mounting—7.2 kV

—

—

—

422D324G06

Obsolete—contact Eaton

—

BA-800 mounting—7.2 kV

—

—

—

422D324G07

Obsolete—contact Eaton

—

BA-800 mounting—7.2 kV

—

—

—

422D324G08

Obsolete—contact Eaton

—

BA-800 mounting—7.2 kV

—

—

—

422D324G09

Obsolete—contact Eaton

—

BA-800 mounting—13.2 kV

—

—

—

422D324G10

Obsolete—contact Eaton

—

BA-800 mounting—13.2 kV

—

—

—

422D324G11

Obsolete—contact Eaton

—

BA-800 mounting—13.2 kV

—

—

—

422D324G12

Obsolete—contact Eaton

—

BA-800 mounting—13.2 kV

—

—

—

422D324G13

Obsolete—contact Eaton

—

BA-800 mounting—14.4 kV

—

—

—

422D324G14

Obsolete—contact Eaton

—

BA-800 mounting—14.4 kV

—

—

—

422D324G15

Obsolete—contact Eaton

—

BA-800 mounting—14.4 kV

—

—

—

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-A2-49

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

422D324G16

Obsolete—contact Eaton

—

423D769G01

Obsolete—contact Eaton

—

BA-800 mounting—14.4 kV

—

—

—

8BA2-MODH

—

—

423D769G02

Obsolete—contact Eaton

—

—

15BA2-MODH

—

—

423D769G03

—

Obsolete—contact Eaton

—

25BA2-MODH

—

—

—

423D769G04

Obsolete—contact Eaton

—

48BA2-MODH

—

—

—

423D769G05

Obsolete—contact Eaton

—

8BA2-75VODH

—

—

—

423D769G06

Obsolete—contact Eaton

—

15BA2-75VODH

—

—

—

423D769G07

Obsolete—contact Eaton

—

25BA2-75VODH

—

—

—

423D769G08

Obsolete—contact Eaton

—

48BA2-75VODH

—

—

—

423D769G09

Obsolete—contact Eaton

—

8BA2-180VODH

—

—

—

423D769G10

Obsolete—contact Eaton

—

15BA2-180VODH

—

—

—

423D769G11

Obsolete—contact Eaton

—

25BA2-180VODH

—

—

—

423D769G12

Obsolete—contact Eaton

—

48BA2-180VODH

—

—

—

423D770G01

Obsolete—contact Eaton

—

8BA4-MODH

—

—

—

423D770G02

Obsolete—contact Eaton

—

15BA4-MODH

—

—

—

423D770G03

Obsolete—contact Eaton

—

25BA4-MODH

—

—

—

423D770G04

Obsolete—contact Eaton

—

48BA4-MODH

—

—

—

423D770G05

Obsolete—contact Eaton

—

8BA4-75VODH

—

—

—

423D770G06

Obsolete—contact Eaton

—

15BA4-75VODH

—

—

—

423D770G07

Obsolete—contact Eaton

—

25BA4-75VODH

—

—

—

423D770G08

Obsolete—contact Eaton

—

48BA4-75VODH

—

—

—

423D770G09

Obsolete—contact Eaton

—

8BA4-180VODH

—

—

—

423D770G10

Obsolete—contact Eaton

—

15BA4-180VODH

—

—

—

423D770G11

Obsolete—contact Eaton

—

25BA4-180VODH

—

—

—

423D770G12

Obsolete—contact Eaton

—

48BA4-180VODH

—

—

—

423D814A05

8RBA2-10E

423D814A05

—

RBA2

8.3

10E

423D814A06

8RBA2-15E

423D814A06

—

RBA2

8.3

15E

423D814A07

8RBA2-20E

423D814A07

—

RBA2

8.3

20E

423D814A08

8RBA2-25E

423D814A08

—

RBA2

8.3

25E

423D814A09

8RBA2-30E

423D814A09

—

RBA2

8.3

30E

423D814A10

8RBA2-40E

423D814A10

—

RBA2

8.3

40E

423D814A11

8RBA2-50E

423D814A11

—

RBA2

8.3

50E

423D814A12

8RBA2-65E

423D814A12

—

RBA2

8.3

65E

423D814A13

8RBA2-80E

423D814A13

—

RBA2

8.3

80E

423D814A14

8RBA2-100E

423D814A14

—

RBA2

8.3

100E

423D814A15

8RBA2-125E

423D814A15

—

RBA2

8.3

125E

423D814A16

8RBA2-150E

423D814A16

—

RBA2

8.3

150E

423D814A17

8RBA2-175E

423D814A17

—

RBA2

8.3

175E

423D814A18

8RBA2-200E

423D814A18

—

RBA2

8.3

200E

423D814A19

15RBA2-10E

423D814A19

—

RBA2

15.5

10E

423D814A20

15RBA2-15E

423D814A20

—

RBA2

15.5

15E

423D814A21

15RBA2-20E

423D814A21

—

RBA2

15.5

20E

423D814A22

15RBA2-25E

423D814A22

—

RBA2

15.5

25E

423D814A23

15RBA2-30E

423D814A23

—

RBA2

15.5

30E

423D814A24

15RBA2-40E

423D814A24

—

RBA2

15.5

40E

423D814A25

15RBA2-50E

423D814A25

—

RBA2

15.5

50E

423D814A26

15RBA2-65E

423D814A26

—

RBA2

15.5

65E

423D814A27

15RBA2-150E

423D814A27

—

RBA2

15.5

80E

423D814A28

15RBA2-100E

423D814A28

—

RBA2

15.5

100E

423D814A29

15RBA2-125E

423D814A29

—

RBA2

15.5

125E

423D814A30

15RBA2-150E

423D814A30

—

RBA2

15.5

150E

423D814A31

15RBA2-175E

423D814A31

—

RBA2

15.5

175E

423D814A32

15RBA2-200E

423D814A32

—

RBA2

15.5

200E

V14-A2-50

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

423D814A33

25RBA2-10E

423D814A33

423D814A34

25RBA2-15E

423D814A34

—

RBA2

25.5

10E

—

RBA2

25.5

423D814A35

25RBA2-20E

15E

423D814A35

—

RBA2

25.5

423D814A36

20E

25RBA2-25E

423D814A36

—

RBA2

25.5

25E

423D814A37

25RBA2-30E

423D814A37

—

RBA2

25.5

30E

423D814A38

25RBA2-40E

423D814A38

—

RBA2

25.5

40E

423D814A39

25RBA2-50E

423D814A39

—

RBA2

25.5

50E

423D814A40

25RBA2-65E

423D814A40

—

RBA2

25.5

65E

423D814A41

25RBA2-250E

423D814A41

—

RBA2

25.5

80E

423D814A42

25RBA2-100E

423D814A42

—

RBA2

25.5

100E

423D814A43

25RBA2-125E

423D814A43

—

RBA2

25.5

125E

423D814A44

25RBA2-150E

423D814A44

—

RBA2

25.5

150E

423D814A45

25RBA2-175E

423D814A45

—

RBA2

25.5

175E

423D814A46

25RBA2-200E

423D814A46

—

RBA2

25.5

200E

423D814A47

38RBA2-10E

423D814A47

—

RBA2

38

10E

423D814A48

38RBA2-15E

423D814A48

—

RBA2

38

15E

423D814A49

38RBA2-20E

423D814A49

—

RBA2

38

20E

423D814A50

38RBA2-25E

423D814A50

—

RBA2

38

25E

423D814A51

38RBA2-30E

423D814A51

—

RBA2

38

30E

423D814A52

38RBA2-40E

423D814A52

—

RBA2

38

40E

423D814A53

38RBA2-50E

423D814A53

—

RBA2

38

50E

423D814A54

38RBA2-65E

423D814A54

—

RBA2

38

65E

423D814A55

38RBA2-380E

423D814A55

—

RBA2

38

80E

423D814A56

38RBA2-100E

423D814A56

—

RBA2

38

100E

423D814A57

38RBA2-125E

423D814A57

—

RBA2

38

125E

423D814A58

38RBA2-150E

423D814A58

—

RBA2

38

150E

423D814A59

38RBA2-175E

423D814A59

—

RBA2

38

175E

423D814A60

38RBA2-200E

423D814A60

—

RBA2

38

200E

423D815A01

8RBA4-.5E

5982C44G01

—

RBA4

8.3

0.5

423D815A02

8RBA4-3E

5982C44G02

—

RBA4

8.3

3

423D815A03

8RBA4-5E

5982C44G03

—

RBA4

8.3

5E

423D815A04

8RBA4-7E

5982C44G04

—

RBA4

8.3

7E

423D815A05

8RBA4-10E

5982C44G05

—

RBA4

8.3

10E

423D815A06

8RBA4-15E

5982C44G06

—

RBA4

8.3

15E

423D815A07

8RBA4-20E

5982C44G07

—

RBA4

8.3

20E

423D815A08

8RBA4-25E

5982C44G08

—

RBA4

8.3

25E

423D815A09

8RBA4-30E

5982C44G09

—

RBA4

8.3

30E

423D815A10

8RBA4-40E

5982C44G10

—

RBA4

8.3

40E

423D815A11

8RBA4-50E

5982C44G11

—

RBA4

8.3

50E

423D815A12

8RBA4-65E

5982C44G12

—

RBA4

8.3

65E

423D815A13

8RBA4-80E

5982C44G13

—

RBA4

8.3

80E

423D815A14

8RBA4-100E

5982C44G14

—

RBA4

8.3

100E

423D815A15

8RBA4-125E

5982C44G15

—

RBA4

8.3

125E

423D815A16

8RBA4-150E

5982C44G16

—

RBA4

8.3

150E

423D815A17

8RBA4-175E

5982C44G17

—

RBA4

8.3

175E

423D815A18

8RBA4-200E

5982C44G18

—

RBA4

8.3

200E

423D815A19

8RBA4-250E

5982C44G19

—

RBA4

8.3

250E

423D815A20

8RBA4-300E

5982C44G20

—

RBA4

8.3

300E

423D815A22

8RBA4-400E

5982C44G22

—

RBA4

8.3

400E

423D815A26

15RBA4-.5E

5982C44G26

—

RBA4

15.5

0.5

423D815A27

15RBA4-3E

5982C44G27

—

RBA4

15.5

3

423D815A28

15RBA4-5E

5982C44G28

—

RBA4

15.5

5E

423D815A29

15RBA4-7E

5982C44G29

—

RBA4

15.5

7E

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-51

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

423D815A30

15RBA4-10E

5982C44G30

423D815A31

15RBA4-15E

5982C44G31

—

RBA4

15.5

10E

—

RBA4

15.5

423D815A32

15RBA4-20E

15E

5982C44G32

—

RBA4

15.5

423D815A33

20E

15RBA4-25E

5982C44G33

—

RBA4

15.5

25E

423D815A34

15RBA4-30E

5982C44G34

—

RBA4

15.5

30E

423D815A35

15RBA4-40E

5982C44G35

—

RBA4

15.5

40E

423D815A36

15RBA4-50E

5982C44G36

—

RBA4

15.5

50E

423D815A37

15RBA4-65E

5982C44G37

—

RBA4

15.5

65E

423D815A38

15RBA4-80E

5982C44G38

—

RBA4

15.5

80E

423D815A39

15RBA4-100E

5982C44G39

—

RBA4

15.5

100E

423D815A40

15RBA4-125E

5982C44G40

—

RBA4

15.5

125E

423D815A41

15RBA4-150E

5982C44G41

—

RBA4

15.5

150E

423D815A42

15RBA4-175E

5982C44G42

—

RBA4

15.5

175E

423D815A43

15RBA4-200E

5982C44G43

—

RBA4

15.5

200E

423D815A44

15RBA4-250E

5982C44G44

—

RBA4

15.5

250E

423D815A45

15RBA4-300E

5982C44G45

—

RBA4

15.5

300E

423D815A47

15RBA4-400E

5982C44G47

—

RBA4

15.5

400E

423D815A51

25RBA4-.5E

5982C44G51

—

RBA4

25.5

0.5

423D815A52

25RBA4-3E

5982C44G52

—

RBA4

25.5

3

423D815A53

25RBA4-5E

5982C44G53

—

RBA4

25.5

5E

423D815A54

25RBA4-7E

5982C44G54

—

RBA4

25.5

7E

423D815A55

25RBA4-10E

5982C44G55

—

RBA4

25.5

10E

423D815A56

25RBA4-15E

5982C44G56

—

RBA4

25.5

15E

423D815A57

25RBA4-20E

5982C44G57

—

RBA4

25.5

20E

423D815A58

25RBA4-25E

5982C44G58

—

RBA4

25.5

25E

423D815A59

25RBA4-30E

5982C44G59

—

RBA4

25.5

30E

423D815A60

25RBA4-40E

5982C44G60

—

RBA4

25.5

40E

423D815A61

25RBA4-50E

5982C44G61

—

RBA4

25.5

50E

423D815A62

25RBA4-65E

5982C44G62

—

RBA4

25.5

65E

423D815A63

25RBA4-80E

5982C44G63

—

RBA4

25.5

80E

423D815A64

25RBA4-100E

5982C44G64

—

RBA4

25.5

100E

423D815A65

25RBA4-125E

5982C44G65

—

RBA4

25.5

125E

423D815A66

25RBA4-150E

5982C44G66

—

RBA4

25.5

150E

423D815A67

25RBA4-175E

5982C44G67

—

RBA4

25.5

175E

423D815A68

25RBA4-200E

5982C44G68

—

RBA4

25.5

200E

423D815A69

25RBA4-250E

5982C44G69

—

RBA4

25.5

250E

423D815A70

25RBA4-300E

5982C44G70

—

RBA4

25.5

300E

423D815A76

38RBA4-.5E

5982C44G76

—

RBA4

38

0.5

423D815A77

38RBA4-3E

5982C44G77

—

RBA4

38

3

423D815A78

38RBA4-5E

5982C44G78

—

RBA4

38

5E

423D815A79

38RBA4-7E

5982C44G79

—

RBA4

38

7E

423D815A80

38RBA4-10E

5982C44G80

—

RBA4

38

10E

423D815A81

38RBA4-15E

5982C44G81

—

RBA4

38

15E

423D815A82

38RBA4-20E

5982C44G82

—

RBA4

38

20E

423D815A83

38RBA4-25E

5982C44G83

—

RBA4

38

25E

423D815A84

38RBA4-30E

5982C44G84

—

RBA4

38

30E

423D815A85

38RBA4-40E

5982C44G85

—

RBA4

38

40E

423D815A86

38RBA4-50E

5982C44G86

—

RBA4

38

50E

423D815A87

38RBA4-65E

5982C44G87

—

RBA4

38

65E

423D815A88

38RBA4-80E

5982C44G88

—

RBA4

38

80E

423D815A89

38RBA4-100E

5982C44G89

—

RBA4

38

100E

423D815A90

38RBA4-125E

5982C44G90

—

RBA4

38

125E

423D815A91

38RBA4-150E

5982C44G91

—

RBA4

38

150E

V14-A2-52

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

423D815A92

38RBA4-175E

5982C44G92

423D815A93

38RBA4-200E

5982C44G93

—

RBA4

38

175E

—

RBA4

38

423D815A94

38RBA4-250E

200E

5982C44G94

—

RBA4

38

423D815A95

250E

38RBA4-300E

5982C44G95

—

RBA4

38

300E

423D816G01

Obsolete—contact Eaton

—

BA-200 mounting—4.8 kV

—

—

—

423D816G02

Obsolete—contact Eaton

—

BA-200 mounting—4.8 kV

—

—

—

423D816G03

Obsolete—contact Eaton

—

BA-200 mounting—4.8 kV

—

—

—

423D816G04

Obsolete—contact Eaton

—

BA-200 mounting—4.8 kV

—

—

—

423D816G05

Obsolete—contact Eaton

—

BA-200 mounting—7.2 kV

—

—

—

423D816G06

Obsolete—contact Eaton

—

BA-200 mounting—7.2 kV

—

—

—

423D816G07

Obsolete—contact Eaton

—

BA-200 mounting—7.2 kV

—

—

—

423D816G08

Obsolete—contact Eaton

—

BA-200 mounting—7.2 kV

—

—

—

423D816G09

Obsolete—contact Eaton

—

BA-200 mounting—13.2 kV

—

—

—

423D816G10

Obsolete—contact Eaton

—

BA-200 mounting—13.2 kV

—

—

—

423D816G11

Obsolete—contact Eaton

—

BA-200 mounting—13.2 kV

—

—

—

423D816G12

Obsolete—contact Eaton

—

BA-200 mounting—13.2 kV

—

—

—

423D816G13

Obsolete—contact Eaton

—

BA-200 mounting—14.4 kV

—

—

—

423D816G14

Obsolete—contact Eaton

—

BA-200 mounting—14.4 kV

—

—

—

423D816G15

Obsolete—contact Eaton

—

BA-200 mounting—14.4 kV

—

—

—

423D816G16

Obsolete—contact Eaton

—

BA-200 mounting—14.4 kV

—

—

—

423D816G17

Obsolete—contact Eaton

—

BA-200 mounting—23 kV

—

—

—

423D816G21

Obsolete—contact Eaton

—

BA-200 mounting—134.5 kV

—

—

—

423D885G01

Obsolete—contact Eaton

—

BA-400 mounting—4.8 kV

—

—

—

423D885G02

Obsolete—contact Eaton

—

BA-400 mounting—4.8 kV

—

—

—

423D885G03

Obsolete—contact Eaton

—

BA-400 mounting—4.8 kV

—

—

—

423D885G04

Obsolete—contact Eaton

—

BA-400 mounting—4.8 kV

—

—

—

423D885G05

Obsolete—contact Eaton

—

BA-400 mounting—7.2 kV

—

—

—

423D885G06

Obsolete—contact Eaton

—

BA-400 mounting—7.2 kV

—

—

—

423D885G07

Obsolete—contact Eaton

—

BA-400 mounting—7.2 kV

—

—

—

423D885G08

Obsolete—contact Eaton

—

BA-400 mounting—7.2 kV

—

—

—

423D885G09

Obsolete—contact Eaton

—

BA-400 mounting—13.2 kV

—

—

—

423D885G10

Obsolete—contact Eaton

—

BA-400 mounting—13.2 kV

—

—

—

423D885G11

Obsolete—contact Eaton

—

BA-400 mounting—13.2 kV

—

—

—

423D885G12

Obsolete—contact Eaton

—

BA-400 mounting—13.2 kV

—

—

—

423D885G13

Obsolete—contact Eaton

—

BA-400 mounting—14.4 kV

—

—

—

423D885G14

Obsolete—contact Eaton

—

BA-400 mounting—14.4 kV

—

—

—

423D885G15

Obsolete—contact Eaton

—

BA-400 mounting—14.4 kV

—

—

—

423D885G16

Obsolete—contact Eaton

—

BA-400 mounting—14.4 kV

—

—

—

42A4072G21

Obsolete—contact Eaton

—

38DBA5-.5E

—

—

—

42A4072G23

Obsolete—contact Eaton

—

38DBA5-5E

—

—

—

42A4072G24

Obsolete—contact Eaton

—

38DBA5-7E

—

—

—

42A4072G25

Obsolete—contact Eaton

—

38DBA5-10E

—

—

—

42A4072G26

Obsolete—contact Eaton

—

38DBA5-15E

—

—

—

42A4072G27

Obsolete—contact Eaton

—

38DBA5-20E

—

—

—

42A4072G28

Obsolete—contact Eaton

—

38DBA5-25E

—

—

—

42A4072G29

Obsolete—contact Eaton

—

38DBA5-30E

—

—

—

42A4072G30

Obsolete—contact Eaton

—

38DBA5-40E

—

—

—

42A4072G31

Obsolete—contact Eaton

—

38DBA5.50E

—

—

—

42A4072G32

Obsolete—contact Eaton

—

38DBA5-65E

—

—

—

42A4072G33

Obsolete—contact Eaton

—

38DBA5-80E

—

—

—

42A4072G34

Obsolete—contact Eaton

—

38DBA5-100E

—

—

—

42A4072G35

Obsolete—contact Eaton

—

38DBA5-125E

—

—

—

42A4072G36

Obsolete—contact Eaton

—

38DBA5-150E

—

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-53

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

42A4072G37

Obsolete—contact Eaton

—

38DBA5-200E

—

—

—

42A4072G41

Obsolete—contact Eaton

—

48DBA5-.5E

—

—

—

42A4072G43

Obsolete—contact Eaton

—

48DBA5-5E

—

—

—

42A4072G44

Obsolete—contact Eaton

—

48DBA5-7E

—

—

—

42A4072G45

Obsolete—contact Eaton

—

48DBA5-10E

—

—

—

42A4072G46

Obsolete—contact Eaton

—

48DBA5-15E

—

—

—

42A4072G47

Obsolete—contact Eaton

—

48DBA5-20E

—

—

—

42A4072G48

Obsolete—contact Eaton

—

48DBA5-25E

—

—

—

42A4072G49

Obsolete—contact Eaton

—

48DBA5-30E

—

—

—

42A4072G50

Obsolete—contact Eaton

—

48DBA5-40E

—

—

—

42A4072G51

Obsolete—contact Eaton

—

48DBA5.50E

—

—

—

42A4072G52

Obsolete—contact Eaton

—

48DBA5-65E

—

—

—

42A4072G53

Obsolete—contact Eaton

—

48DBA5-80E

—

—

—

42A4072G54

Obsolete—contact Eaton

—

48DBA5-100E

—

—

—

42A4072G55

Obsolete—contact Eaton

—

48DBA5-125E

—

—

—

42A4072G56

Obsolete—contact Eaton

—

48DBA5-150E

—

—

—

42A4072G57

Obsolete—contact Eaton

—

48DBA5-200E

—

—

—

42A4072G61

Obsolete—contact Eaton

—

72DBA5-.5E

—

—

—

42A4072G63

Obsolete—contact Eaton

—

72DBA5-5E

—

—

—

42A4072G64

Obsolete—contact Eaton

—

72DBA5-7E

—

—

—

42A4072G65

Obsolete—contact Eaton

—

72DBA5-10E

—

—

—

42A4072G66

Obsolete—contact Eaton

—

72DBA5-15E

—

—

—

42A4072G67

Obsolete—contact Eaton

—

72DBA5-20E

—

—

—

42A4072G68

Obsolete—contact Eaton

—

72DBA5-25E

—

—

—

42A4072G69

Obsolete—contact Eaton

—

72DBA5-30E

—

—

—

42A4072G70

Obsolete—contact Eaton

—

72DBA5-40E

—

—

—

42A4072G71

Obsolete—contact Eaton

—

72DBA5.50E

—

—

—

42A4072G72

Obsolete—contact Eaton

—

72DBA5-65E

—

—

—

42A4072G73

Obsolete—contact Eaton

—

72DBA5-80E

—

—

—

42A4072G74

Obsolete—contact Eaton

—

72DBA5-100E

—

—

—

42A4072G75

Obsolete—contact Eaton

—

72DBA5-125E

—

—

—

42A4072G76

Obsolete—contact Eaton

—

72DBA5-150E

—

—

—

42A4072G77

Obsolete—contact Eaton

—

72DBA5-200E

—

—

—

431B345G01

2CLE-20E

678C240G02

—

CLE

2.75

20E

431B346G01

5CLE-20E

678C240G05

—

CLE

5.5

20E

431B347G01

8CLE-15E

678C240G07

—

CLE

8.3

15E

431B348G01

8CLE-20E

678C240G08

—

CLE

8.3

20E

431B349G01

8CLE-25E

678C240G09

—

CLE

8.3

25E

431B350G01

15CLE-15E

678C240G10

—

CLE

15.5

15E

431B351G01

15CLE-20E

678C240G11

—

CLE

15.5

20E

431B373G01

15CLE-50E

678C240G12

—

CLE

15.5

25E

431B374G09

15CLE-65E

5981C19G06

—

CLE

15.5

65E

432D140A02

2CLE-PDM-D

9078A65G15

—

CLE

2.75

250

432D140A04

2CLE-PDM-D

9078A65G15

—

CLE

2.75

250

432D140A05

5CLE-PDM-D

9078A65G16

—

CLE

5.5

250

432D140A06

8CLE-PDM-D

9078A65G17

—

CLE

8.3

175

432D140A07

2CLE-PDM-D

9078A65G15

—

CLE

2.75

250

432D140A10

15CLE-PDM-D

9078A65G18

—

CLE

15.5

150

432D140A11

15CLE-HPDM-D

9078A65G19

—

CLE

15.5

150

432D140A13

Obsolete—contact Eaton

—

Rear connected disconnect CLE mountings

—

—

—

432D140A15

Obsolete—contact Eaton

—

Rear connected disconnect CLE mountings

—

—

—

432D140A16

Obsolete—contact Eaton

—

Rear connected disconnect CLE mountings

—

—

—

432D140A20

Obsolete—contact Eaton

—

Rear connected disconnect CLE mountings

—

—

—

V14-A2-54

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

432D140A21

Obsolete—contact Eaton

—

432D140A23

Obsolete—contact Eaton

—

Rear connected disconnect CLE mountings

—

—

—

Rear connected disconnect CLE mountings

—

—

432D140A25

Obsolete—contact Eaton

—

—

Rear connected disconnect CLE mountings

—

—

432D140A26

—

Obsolete—contact Eaton

—

Rear connected disconnect CLE mountings

—

—

—

432D140A30

Obsolete—contact Eaton

—

Rear connected disconnect CLE mountings

—

—

—

432D140A31

Obsolete—contact Eaton

—

Rear connected disconnect CLE mountings

—

—

—

432D140A33

Obsolete—contact Eaton

—

Rear connected disconnect CLE mountings

—

—

—

432D140A35

Obsolete—contact Eaton

—

Rear connected disconnect CLE mountings

—

—

—

432D140A36

Obsolete—contact Eaton

—

Rear connected disconnect CLE mountings

—

—

—

432D140A40

Obsolete—contact Eaton

—

Rear connected disconnect CLE mountings

—

—

—

432D140A41

Obsolete—contact Eaton

—

Rear connected disconnect CLE mountings

—

—

—

432D886G06

2CLE-250E

449D797G13

—

CLE

2.75

250E

432D886G14

5CLE-250E

5981C65G10

—

CLE

5.5

250E

434D316A04

Obsolete—contact Eaton

—

8BT2-15E

—

—

—

434D316A05

Obsolete—contact Eaton

—

8BT2-20E

—

—

—

434D316A06

Obsolete—contact Eaton

—

8BT2-25E

—

—

—

434D316A07

Obsolete—contact Eaton

—

8BT2-30E

—

—

—

434D316A08

Obsolete—contact Eaton

—

8BT2-40E

—

—

—

434D316A09

Obsolete—contact Eaton

—

8BT2-50E

—

—

—

434D316A10

Obsolete—contact Eaton

—

8BT2-65E

—

—

—

434D316A11

Obsolete—contact Eaton

—

8BT2-80E

—

—

—

434D316A12

Obsolete—contact Eaton

—

8BT2-100E

—

—

—

434D316A13

Obsolete—contact Eaton

—

8BT2-125E

—

—

—

434D316A14

Obsolete—contact Eaton

—

8BT2-150E

—

—

—

434D316A15

Obsolete—contact Eaton

—

8BT2-200E

—

—

—

434D316A19

Obsolete—contact Eaton

—

15BT2-15E

—

—

—

434D316A20

Obsolete—contact Eaton

—

15BT2-20E

—

—

—

434D316A21

Obsolete—contact Eaton

—

15BT2-25E

—

—

—

434D316A22

Obsolete—contact Eaton

—

15BT2-30E

—

—

—

434D316A23

Obsolete—contact Eaton

—

15BT2-40E

—

—

—

434D316A24

Obsolete—contact Eaton

—

15BT2-50E

—

—

—

434D316A25

Obsolete—contact Eaton

—

15BT2-65E

—

—

—

434D316A26

Obsolete—contact Eaton

—

15BT2-80E

—

—

—

434D316A27

Obsolete—contact Eaton

—

15BT2-100E

—

—

—

434D316A28

Obsolete—contact Eaton

—

15BT2-125E

—

—

—

434D316A29

Obsolete—contact Eaton

—

15BT2-150E

—

—

—

434D316A30

Obsolete—contact Eaton

—

15BT2-200E

—

—

—

434D316A34

Obsolete—contact Eaton

—

25BT2-15E

—

—

—

434D316A35

Obsolete—contact Eaton

—

25BT2-20E

—

—

—

434D316A36

Obsolete—contact Eaton

—

25BT2-25E

—

—

—

434D316A37

Obsolete—contact Eaton

—

25BT2-30E

—

—

—

434D316A48

Obsolete—contact Eaton

—

25BT2-40E

—

—

—

434D316A39

Obsolete—contact Eaton

—

25BT2-50E

—

—

—

434D316A40

Obsolete—contact Eaton

—

25BT2-65E

—

—

—

434D316A41

Obsolete—contact Eaton

—

25BT2-80E

—

—

—

434D316A42

Obsolete—contact Eaton

—

25BT2-100E

—

—

—

434D316A43

Obsolete—contact Eaton

—

25BT2-125E

—

—

—

434D316A44

Obsolete—contact Eaton

—

25BT2-150E

—

—

—

434D316A45

Obsolete—contact Eaton

—

25BT2-200E

—

—

—

434D316A49

Obsolete—contact Eaton

—

38BT2-15E

—

—

—

434D316A50

Obsolete—contact Eaton

—

38BT2-20E

—

—

—

434D316A51

Obsolete—contact Eaton

—

38BT2-25E

—

—

—

434D316A52

Obsolete—contact Eaton

—

38BT2-30E

—

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-55

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

434D316A53

Obsolete—contact Eaton

—

434D316A54

Obsolete—contact Eaton

—

38BT2-40E

—

—

—

38BT2-50E

—

—

434D316A55

Obsolete—contact Eaton

—

—

38BT2-65E

—

—

434D316A56

—

Obsolete—contact Eaton

—

38BT2-80E

—

—

—

434D316A57

Obsolete—contact Eaton

—

38BT2-100E

—

—

—

434D316A58

Obsolete—contact Eaton

—

38BT2-125E

—

—

—

434D316A59

Obsolete—contact Eaton

—

38BT2-150E

—

—

—

434D316A60

Obsolete—contact Eaton

—

38BT2-200E

—

—

—

434D317A05

Obsolete—contact Eaton

—

8BT4-20E

—

—

—

434D317A06

Obsolete—contact Eaton

—

8BT4-25E

—

—

—

434D317A07

Obsolete—contact Eaton

—

8BT4-30E

—

—

—

434D317A08

Obsolete—contact Eaton

—

8BT4-40E

—

—

—

434D317A09

Obsolete—contact Eaton

—

8BT4-50E

—

—

—

434D317A10

Obsolete—contact Eaton

—

8BT4-65E

—

—

—

434D317A11

Obsolete—contact Eaton

—

8BT4-80E

—

—

—

434D317A12

Obsolete—contact Eaton

—

8BT4-100E

—

—

—

434D317A13

Obsolete—contact Eaton

—

8BT4-125E

—

—

—

434D317A14

Obsolete—contact Eaton

—

8BT4-150E

—

—

—

434D317A15

Obsolete—contact Eaton

—

8BT4-200E

—

—

—

434D317A23

Obsolete—contact Eaton

—

15BT4-20E

—

—

—

434D317A24

Obsolete—contact Eaton

—

15BT4-25E

—

—

—

434D317A25

Obsolete—contact Eaton

—

15BT4-30E

—

—

—

434D317A26

Obsolete—contact Eaton

—

15BT4-40E

—

—

—

434D317A27

Obsolete—contact Eaton

—

15BT4-50E

—

—

—

434D317A28

Obsolete—contact Eaton

—

15BT4-65E

—

—

—

434D317A29

Obsolete—contact Eaton

—

15BT4-150E

—

—

—

434D317A30

Obsolete—contact Eaton

—

15BT4-100E

—

—

—

434D317A31

Obsolete—contact Eaton

—

15BT4-125E

—

—

—

434D317A32

Obsolete—contact Eaton

—

15BT4-150E

—

—

—

434D317A33

Obsolete—contact Eaton

—

15BT4-200E

—

—

—

434D317A41

Obsolete—contact Eaton

—

25BT4-20E

—

—

—

434D317A42

Obsolete—contact Eaton

—

25BT4-25E

—

—

—

434D317A43

Obsolete—contact Eaton

—

25BT4-30E

—

—

—

434D317A44

Obsolete—contact Eaton

—

25BT4-40E

—

—

—

434D317A45

Obsolete—contact Eaton

—

25BT4-50E

—

—

—

434D317A46

Obsolete—contact Eaton

—

25BT4-65E

—

—

—

434D317A47

Obsolete—contact Eaton

—

25BT4-250E

—

—

—

434D317A48

Obsolete—contact Eaton

—

25BT4-100E

—

—

—

434D317A49

Obsolete—contact Eaton

—

25BT4-125E

—

—

—

434D317A50

Obsolete—contact Eaton

—

25BT4-150E

—

—

—

434D317A51

Obsolete—contact Eaton

—

25BT4-200E

—

—

—

434D317A59

Obsolete—contact Eaton

—

38BT4-20E

—

—

—

434D317A60

Obsolete—contact Eaton

—

38BT4-25E

—

—

—

434D317A61

Obsolete—contact Eaton

—

38BT4-30E

—

—

—

434D317A62

Obsolete—contact Eaton

—

38BT4-40E

—

—

—

434D317A63

Obsolete—contact Eaton

—

38BT4-50E

—

—

—

434D317A64

Obsolete—contact Eaton

—

38BT4-65E

—

—

—

434D317A65

Obsolete—contact Eaton

—

38BT4-380E

—

—

—

434D317A66

Obsolete—contact Eaton

—

38BT4-100E

—

—

—

434D317A67

Obsolete—contact Eaton

—

38BT4-125E

—

—

—

434D317A68

Obsolete—contact Eaton

—

38BT4-150E

—

—

—

434D317A69

Obsolete—contact Eaton

—

38BT4-200E

—

—

—

434D641G01

Obsolete—contact Eaton

—

DBA3 69 kV—300E fuse

—

—

—

V14-A2-56

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

434D650G01

Obsolete—contact Eaton

—

434D650G02

Obsolete—contact Eaton

—

BA-800 mounting—4.8 kV

—

—

—

BA-800 mounting—4.8 kV

—

—

434D650G03

Obsolete—contact Eaton

—

—

BA-800 mounting—4.8 kV

—

—

434D650G04

—

Obsolete—contact Eaton

—

BA-800 mounting—4.8 kV

—

—

—

434D650G05

Obsolete—contact Eaton

—

BA-800 mounting—7.2 kV

—

—

—

434D650G06

Obsolete—contact Eaton

—

BA-800 mounting—7.2 kV

—

—

—

434D650G07

Obsolete—contact Eaton

—

BA-800 mounting—7.2 kV

—

—

—

434D650G08

Obsolete—contact Eaton

—

BA-800 mounting—7.2 kV

—

—

—

434D650G09

Obsolete—contact Eaton

—

BA-800 mounting—13.2 kV

—

—

—

434D650G10

Obsolete—contact Eaton

—

BA-800 mounting—13.2 kV

—

—

—

434D650G11

Obsolete—contact Eaton

—

BA-800 mounting—13.2 kV

—

—

—

434D650G12

Obsolete—contact Eaton

—

BA-800 mounting—13.2 kV

—

—

—

434D650G13

Obsolete—contact Eaton

—

BA-800 mounting—14.4 kV

—

—

—

434D650G14

Obsolete—contact Eaton

—

BA-800 mounting—14.4 kV

—

—

—

434D650G15

Obsolete—contact Eaton

—

BA-800 mounting—14.4 kV

—

—

—

434D650G16

Obsolete—contact Eaton

—

BA-800 mounting—14.4 kV

—

—

—

434D830A01

Obsolete—contact Eaton

—

DBA-1—7.2 kV vertical mounting

—

—

—

434D830A02

Obsolete—contact Eaton

—

DBA-1—14.4 kV vertical mounting

—

—

—

434D830A03

Obsolete—contact Eaton

—

DBA-1—23 kV vertical mounting

—

—

—

434D830A04

Obsolete—contact Eaton

—

DBA-1—34.5 kV vertical mounting

—

—

—

434D830A05

Obsolete—contact Eaton

—

DBA-1—46 kV vertical mounting

—

—

—

434D830A09

Obsolete—contact Eaton

—

DBA-1—69 kV vertical mounting

—

—

—

434D831A01

Obsolete—contact Eaton

—

DBA-2/5—34.5 kV vertical mounting

—

—

—

434D831A02

Obsolete—contact Eaton

—

DBA-2/5—46 kV vertical mounting

—

—

—

434D831A09

Obsolete—contact Eaton

—

DBA-2/5—69 kV vertical mounting

—

—

—

434D831A10

Obsolete—contact Eaton

—

DBA-2—92 kV mounting

—

—

—

434D831A11

Obsolete—contact Eaton

—

DBA-2—115 kV mounting

—

—

—

434D831A12

Obsolete—contact Eaton

—

DBA-2—138 kV mounting

—

—

—

435B590G02

CLS-BAND

435B590G02

—

CLS

—

—

436B732G01

PF8-5

436B732G01

—

EMOLD

—

—

436B732G03

PF8-8

436B732G03

—

EMOLD

—

—

436B732G05

PF8-12

436B732G05

—

EMOLD

—

—

436B732G07

PF8-18

436B732G07

—

EMOLD

—

—

436B764G01

Obsolete—contact Eaton

—

DBA-1—7.2 kV inverted mounting

—

—

—

436B764G02

Obsolete—contact Eaton

—

DBA-1—14.4 kV inverted mounting

—

—

—

436B764G03

Obsolete—contact Eaton

—

DBA-1—23 kV inverted mounting

—

—

—

436B764G04

Obsolete—contact Eaton

—

DBA-1—34.5 kV inverted mounting

—

—

—

436B764G05

Obsolete—contact Eaton

—

DBA-1—46 kV inverted mounting

—

—

—

436B764G10

Obsolete—contact Eaton

—

DBA-1—69 kV inverted mounting

—

—

—

436B764G20

Obsolete—contact Eaton

—

DBA-2/5—34.5 kV inverted mounting

—

—

—

436B764G21

Obsolete—contact Eaton

—

DBA-2/5—46 kV inverted mounting

—

—

—

436B764G22

Obsolete—contact Eaton

—

DBA-2/5—69 kV inverted mounting

—

—

—

438D724A01

RDB2-VL

438D724A01

—

RDB2

—

200

438D724G01

Obsolete—contact Eaton

—

4.8/7.2 kV 95BIL RDB-2 mounting cap and pin

—

—

—

438D724G02

Obsolete—contact Eaton

—

15 kV 110BIL RDB-2 mounting cap and pin

—

—

—

438D724G03

Obsolete—contact Eaton

—

23 kV 150BIL RDB-2 mounting cap and pin

—

—

—

438D724G04

Obsolete—contact Eaton

—

34.5 kV 200BIL RDB-2 mounting cap and pin

—

—

—

438D724G05

Obsolete—contact Eaton

—

4.8/7.2 kV 110BIL RDB-2 mounting cap and pin

—

—

—

438D724G06

Obsolete—contact Eaton

—

15 kV 150BIL RDB-2 mounting cap and pin

—

—

—

438D724G07

Obsolete—contact Eaton

—

23 kV 200BIL RDB-2 mounting cap and pin

—

—

—

438D724G08

Obsolete—contact Eaton

—

34.5 kV 250BIL RDB-2 mounting cap and pin

—

—

—

438D724G09

8RDB2-VM

438D724G09

—

RDB2

8.3

200

438D724G10

15RDB2-VM

438D724G10

—

RDB2

15.5

200

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-57

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

438D724G11

25RDB2-VM

438D724G11

—

RDB2

25.5

200

438D724G12

38RDB2-VM

438D724G12

—

RDB2

38

200

438D724G13

8RDB2-HVM

438D724G13

—

RDB2

8.3

200

438D724G14

15RDB2-HVM

438D724G14

—

RDB2

15.5

200

438D724G15

25RDB2-HVM

438D724G15

—

RDB2

25.5

200

438D724G16

38RDB2-HVM

438D724G16

—

RDB2

38

200

438D725A01

RDB4-VL

438D725A01

—

RDB4

—

400

438D725G01

Obsolete—contact Eaton

—

4.8/7.2 kV 95BIL RDB-4 mounting cap and pin

—

—

—

438D725G02

Obsolete—contact Eaton

—

15 kV 110BIL RDB-4 mounting cap and pin

—

—

—

438D725G03

Obsolete—contact Eaton

—

23 kV 150BIL RDB-4 mounting cap and pin

—

—

—

438D725G04

Obsolete—contact Eaton

—

34.5 kV 200BIL RDB-4 mounting cap and pin

—

—

—

438D725G05

Obsolete—contact Eaton

—

4.8/7.2 kV 110BIL RDB-4 mounting cap and pin

—

—

—

438D725G06

Obsolete—contact Eaton

—

15 kV 150BIL RDB-4 mounting cap and pin

—

—

—

438D725G07

Obsolete—contact Eaton

—

23 kV 200BIL RDB-4 mounting cap and pin

—

—

—

438D725G08

Obsolete—contact Eaton

—

34.5 kV 250BIL RDB-4 mounting cap and pin

—

—

—

438D725G09

8RDB4-VM

438D725G09

—

RDB4

8.3

400

438D725G10

15RDB4-VM

438D725G10

—

RDB4

15.5

400

438D725G11

25RDB4-VM

438D725G11

—

RDB4

25.5

300

438D725G12

38RDB4-VM

438D725G12

—

RDB4

38

300

438D725G13

8RDB4-HVM

438D725G13

—

RDB4

8.3

400

438D725G14

15RDB4-HVM

438D725G14

—

RDB4

15.5

400

438D725G15

25RDB4-HVM

438D725G15

—

RDB4

25.5

300

438D725G16

38RDB4-HVM

438D725G16

—

RDB4

38

300

438D726A02

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-2 rear connected live parts

—

—

—

438D726A03

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-2 rear connected live parts

—

—

—

438D726A04

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-2 rear connected live parts

—

—

—

438D726A06

Obsolete—contact Eaton

—

13.8 kV RBA-2 rear connected live parts

—

—

—

438D726A07

Obsolete—contact Eaton

—

13.8 kV RBA-2 rear connected live parts

—

—

—

438D726A08

Obsolete—contact Eaton

—

13.8 kV RBA-2 rear connected live parts

—

—

—

438D726A10

Obsolete—contact Eaton

—

14.4 kV RBA-2 rear connected live parts

—

—

—

438D726A11

Obsolete—contact Eaton

—

14.4 kV RBA-2 rear connected live parts

—

—

—

438D726A12

Obsolete—contact Eaton

—

14.4 kV RBA-2 rear connected live parts

—

—

—

438D726G02

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-2 rear connected mountings

—

—

—

438D726G03

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-2 rear connected mountings

—

—

—

438D726G04

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-2 rear connected mountings

—

—

—

438D726G06

Obsolete—contact Eaton

—

7.2 kV RBA-2 rear connected mountings

—

—

—

438D726G07

Obsolete—contact Eaton

—

7.2 kV RBA-2 rear connected mountings

—

—

—

438D726G08

Obsolete—contact Eaton

—

7.2 kV RBA-2 rear connected mountings

—

—

—

438D726G10

Obsolete—contact Eaton

—

13.8 kV RBA-2 rear connected mountings

—

—

—

438D726G11

Obsolete—contact Eaton

—

13.8 kV RBA-2 rear connected mountings

—

—

—

438D726G12

Obsolete—contact Eaton

—

13.8 kV RBA-2 rear connected mountings

—

—

—

438D726G14

Obsolete—contact Eaton

—

14.4 kV RBA-2 rear connected mountings

—

—

—

438D726G15

Obsolete—contact Eaton

—

14.4 kV RBA-2 rear connected mountings

—

—

—

438D726G16

Obsolete—contact Eaton

—

14.4 kV RBA-2 rear connected mountings

—

—

—

438D727A02

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-4 rear connected live parts

—

—

—

438D727A03

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-4 rear connected live parts

—

—

—

438D727A04

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-4 rear connected live parts

—

—

—

438D727A06

Obsolete—contact Eaton

—

13.8 kV RBA-4 rear connected live parts

—

—

—

438D727A07

Obsolete—contact Eaton

—

13.8 kV RBA-4 rear connected live parts

—

—

—

438D727A08

Obsolete—contact Eaton

—

13.8 kV RBA-4 rear connected live parts

—

—

—

438D727A10

Obsolete—contact Eaton

—

14.4 kV RBA-4 rear connected live parts

—

—

—

438D727A11

Obsolete—contact Eaton

—

14.4 kV RBA-4 rear connected live parts

—

—

—

438D727A12

Obsolete—contact Eaton

—

14.4 kV RBA-4 rear connected live parts

—

—

—

V14-A2-58

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current
Rating
Amperes

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

438D727G02

Obsolete—contact Eaton

—

438D727G03

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-4 rear connected mountings

—

—

—

2.4/4.8 kV RBA-4 rear connected mountings

—

—

438D727G04

Obsolete—contact Eaton

—

—

2.4/4.8 kV RBA-4 rear connected mountings

—

—

438D727G06

—

Obsolete—contact Eaton

—

7.2 kV RBA-4 rear connected mountings

—

—

—

438D727G07

Obsolete—contact Eaton

—

7.2 kV RBA-4 rear connected mountings

—

—

—

438D727G08

Obsolete—contact Eaton

—

7.2 kV RBA-4 rear connected mountings

—

—

—

438D727G10

Obsolete—contact Eaton

—

13.8 kV RBA-4 rear connected mountings

—

—

—

438D727G11

Obsolete—contact Eaton

—

13.8 kV RBA-4 rear connected mountings

—

—

—

438D727G12

Obsolete—contact Eaton

—

13.8 kV RBA-4 rear connected mountings

—

—

—

438D727G14

Obsolete—contact Eaton

—

14.4 kV RBA-4 rear connected mountings

—

—

—

438D727G15

Obsolete—contact Eaton

—

14.4 kV RBA-4 rear connected mountings

—

—

—

438D727G16

Obsolete—contact Eaton

—

14.4 kV RBA-4 rear connected mountings

—

—

—

438D727G18

Obsolete—contact Eaton

—

23 kV RBA-4 rear connected mountings

—

—

—

438D727G19

Obsolete—contact Eaton

—

24 kV RBA-4 rear connected mountings

—

—

—

438D727G20

Obsolete—contact Eaton

—

25 kV RBA-4 rear connected mountings

—

—

—

439D347A02

Obsolete—contact Eaton

—

4.8/14.4 kV rear connected live parts

—

—

—

439D347A03

Obsolete—contact Eaton

—

4.8/14.4 kV rear connected live parts

—

—

—

439D347A04

Obsolete—contact Eaton

—

4.8/14.4 kV rear connected live parts

—

—

—

439D347G02

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-2 rear connected mountings

—

—

—

439D347G03

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-2 rear connected mountings

—

—

—

439D347G04

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-2 rear connected mountings

—

—

—

439D347G06

Obsolete—contact Eaton

—

7.2 kV RBA-2 rear connected mountings

—

—

—

439D347G07

Obsolete—contact Eaton

—

7.2 kV RBA-2 rear connected mountings

—

—

—

439D347G08

Obsolete—contact Eaton

—

7.2 kV RBA-2 rear connected mountings

—

—

—

439D347G10

Obsolete—contact Eaton

—

13.8 kV RBA-2 rear connected mountings

—

—

—

439D347G11

Obsolete—contact Eaton

—

13.8 kV RBA-2 rear connected mountings

—

—

—

439D347G12

Obsolete—contact Eaton

—

13.8 kV RBA-2 rear connected mountings

—

—

—

439D347G14

Obsolete—contact Eaton

—

14.4 kV RBA-2 rear connected mountings

—

—

—

439D347G15

Obsolete—contact Eaton

—

14.4 kV RBA-2 rear connected mountings

—

—

—

439D347G16

Obsolete—contact Eaton

—

14.4 kV RBA-2 rear connected mountings

—

—

—

439D349A02

Obsolete—contact Eaton

—

4.8/14.4 kV RBA-4 rear connected live parts

—

—

—

439D349A03

Obsolete—contact Eaton

—

4.8/14.4 kV RBA-4 rear connected live parts

—

—

—

439D349A04

Obsolete—contact Eaton

—

4.8/14.4 kV RBA-4 rear connected live parts

—

—

—

439D349G02

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-4 rear connected mountings

—

—

—

439D349G03

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-4 rear connected mountings

—

—

—

439D349G04

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-4 rear connected mountings

—

—

—

439D349G06

Obsolete—contact Eaton

—

7.2 kV RBA-4 rear connected mountings

—

—

—

439D349G07

Obsolete—contact Eaton

—

7.2 kV RBA-4 rear connected mountings

—

—

—

439D349G08

Obsolete—contact Eaton

—

7.2 kV RBA-4 rear connected mountings

—

—

—

439D349G10

Obsolete—contact Eaton

—

13.8 kV RBA-4 rear connected mountings

—

—

—

439D349G11

Obsolete—contact Eaton

—

13.8 kV RBA-4 rear connected mountings

—

—

—

439D349G12

Obsolete—contact Eaton

—

13.8 kV RBA-4 rear connected mountings

—

—

—

439D349G14

Obsolete—contact Eaton

—

14.4 kV RBA-4 rear connected mountings

—

—

—

439D349G15

Obsolete—contact Eaton

—

14.4 kV RBA-4 rear connected mountings

—

—

—

439D349G16

Obsolete—contact Eaton

—

14.4 kV RBA-4 rear connected mountings

—

—

—

439D350A13

Obsolete—contact Eaton

—

2.4 kV rear connected CLS mounting

—

—

—

439D350A15

Obsolete—contact Eaton

—

4.8 kV rear connected CLS mounting

—

—

—

439D350A16

Obsolete—contact Eaton

—

4.8 kV rear connected CLS mounting

—

—

—

439D350A23

Obsolete—contact Eaton

—

2.4 kV rear connected CLS mounting

—

—

—

439D350A25

Obsolete—contact Eaton

—

4.8 kV rear connected CLS mounting

—

—

—

439D350A26

Obsolete—contact Eaton

—

4.8 kV rear connected CLS mounting

—

—

—

439D350A33

Obsolete—contact Eaton

—

2.4 kV rear connected CLS mounting

—

—

—

439D350A35

Obsolete—contact Eaton

—

4.8 kV rear connected CLS mounting

—

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-59

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

439D350A36

Obsolete—contact Eaton

—

439D378G03

15CLE-30E

5981C33G05

4.8 kV rear connected CLS mounting

—

—

—

—

CLE

15.5

439D378G04

15CLE-40E

30E

5981C19G04

—

CLE

15.5

439D378G05

40E

15CLE-50E

5981C19G05

—

CLE

15.5

50E

439D378G06

15CLE-65E

5981C19G06

—

CLE

15.5

65E

439D482G04

15CLE-80E

5981C19G07

—

CLE

15.5

80E

439D482G05

15CLE-100E

5981C19G08

—

CLE

15.5

100E

439D482G06

15CLE-125E

5981C19G09

—

CLE

15.5

125E

449D339G03

Obsolete—contact Eaton

—

600V 600A SCL fuse

—

—

—

449D361G01

5ACLS-2R

449D597G02

—

CLS

5.08

2R(70)

449D361G02

5ACLS-3R

449D597G03

—

CLS

5.08

3R(100)

449D361G03

5ACLS-4R

449D597G04

—

CLS

5.08

4R(130)

449D361G04

5ACLS-5R

449D597G05

—

CLS

5.08

5R(150)

449D361G05

5ACLS-6R

449D597G06

—

CLS

5.08

6R(170)

449D361G06

5ACLS-9R

151D933H01

—

CLS

5.08

9R(200)

449D361G07

5ACLS-12R

151D933H02

—

CLS

5.08

12R(230)

449D361G08

5ACLS-30

449D597G01

—

CLS

5.08

30

449D362G01

5AHLE-30E

5981C46G05

—

HLE

5.5

30E

449D362G02

5AHLE-50E

5981C46G07

—

HLE

5.5

50E

449D362G03

5AHLE-65E

5981C46G08

—

HLE

5.5

65E

449D362G04

5AHLE-80E

5981C46G09

—

HLE

5.5

80E

449D362G05

5AHLE-100E

5981C46G10

—

HLE

5.5

100E

449D362G06

5AHLE-125E

5981C46G11

—

HLE

5.5

125E

449D362G07

5AHLE-150E

5981C46G12

—

HLE

5.5

150E

449D362G08

5AHLE-200E

5981C46G14

—

HLE

5.5

200E

449D362G09

Obsolete—contact Eaton

—

5ACLE-225E

—

—

—

449D362G10

5AHLE-25E

5981C46G04

—

HLE

5.5

25E

449D472A02

Obsolete—contact Eaton

—

4.8/14 kV RBA-800 rear connected live parts

—

—

—

449D472A03

Obsolete—contact Eaton

—

4.8/14 kV RBA-800 rear connected live parts

—

—

—

449D472A04

Obsolete—contact Eaton

—

4.8/14 kV RBA-800 rear connected live parts

—

—

—

449D472G02

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-800 rear connected mountings

—

—

—

449D472G03

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-800 rear connected mountings

—

—

—

449D472G04

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-800 rear connected mountings

—

—

—

449D472G06

Obsolete—contact Eaton

—

7.2 kV RBA-800 rear connected mountings

—

—

—

449D472G07

Obsolete—contact Eaton

—

7.2 kV RBA-800 rear connected mountings

—

—

—

449D472G08

Obsolete—contact Eaton

—

7.2 kV RBA-800 rear connected mountings

—

—

—

449D472G10

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected mountings

—

—

—

449D472G11

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected mountings

—

—

—

449D472G12

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected mountings

—

—

—

449D472G14

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected mountings

—

—

—

449D472G15

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected mountings

—

—

—

449D472G16

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected mountings

—

—

—

449D513A01

Obsolete—contact Eaton

—

2.4/15 kV RBA-800 rear connected live parts

—

—

—

449D513A02

Obsolete—contact Eaton

—

2.4/15 kV RBA-800 rear connected live parts

—

—

—

449D513A03

Obsolete—contact Eaton

—

2.4/15 kV RBA-800 rear connected live parts

—

—

—

449D513A04

Obsolete—contact Eaton

—

2.4/15 kV RBA-800 rear connected live parts

—

—

—

449D513A05

Obsolete—contact Eaton

—

2.4/15 kV RBA-800 rear connected live parts

—

—

—

449D513G01

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-800 rear connected mountings

—

—

—

449D513G02

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-800 rear connected mountings

—

—

—

449D513G03

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-800 rear connected mountings

—

—

—

449D513G04

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-800 rear connected mountings

—

—

—

449D513G05

Obsolete—contact Eaton

—

7.2 kV RBA-800 rear connected mountings

—

—

—

449D513G06

Obsolete—contact Eaton

—

7.2 kV RBA-800 rear connected mountings

—

—

—

V14-A2-60

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

449D513G07

Obsolete—contact Eaton

—

449D513G08

Obsolete—contact Eaton

—

7.2 kV RBA-800 rear connected mountings

—

—

—

7.2 kV RBA-800 rear connected mountings

—

—

449D513G09

Obsolete—contact Eaton

—

—

13.8 kV RBA-800 rear connected mountings

—

—

449D513G10

—

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected mountings

—

—

—

449D513G11

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected mountings

—

—

—

449D513G12

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected mountings

—

—

—

449D513G13

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected mountings

—

—

—

449D513G14

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected mountings

—

—

—

449D513G15

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected mountings

—

—

—

449D513G16

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected mountings

—

—

—

449D514A01

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-800 rear connected live parts

—

—

—

449D514A02

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-800 rear connected live parts

—

—

—

449D514A03

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-800 rear connected live parts

—

—

—

449D514A04

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-800 rear connected live parts

—

—

—

449D514A05

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected live parts

—

—

—

449D514A06

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected live parts

—

—

—

449D514A07

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected live parts

—

—

—

449D514A08

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected live parts

—

—

—

449D514A09

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected live parts

—

—

—

449D514A10

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected live parts

—

—

—

449D514A11

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected live parts

—

—

—

449D514A12

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected live parts

—

—

—

449D514G01

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-800 rear connected mountings

—

—

—

449D514G02

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-800 rear connected mountings

—

—

—

449D514G03

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-800 rear connected mountings

—

—

—

449D514G04

Obsolete—contact Eaton

—

2.4/4.8 kV RBA-800 rear connected mountings

—

—

—

449D514G05

Obsolete—contact Eaton

—

7.2 kV RBA-800 rear connected mountings

—

—

—

449D514G06

Obsolete—contact Eaton

—

7.2 kV RBA-800 rear connected mountings

—

—

—

449D514G07

Obsolete—contact Eaton

—

7.2 kV RBA-800 rear connected mountings

—

—

—

449D514G08

Obsolete—contact Eaton

—

7.2 kV RBA-800 rear connected mountings

—

—

—

449D514G09

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected mountings

—

—

—

449D514G10

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected mountings

—

—

—

449D514G11

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected mountings

—

—

—

449D514G12

Obsolete—contact Eaton

—

13.8 kV RBA-800 rear connected mountings

—

—

—

449D514G13

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected mountings

—

—

—

449D514G14

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected mountings

—

—

—

449D514G15

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected mountings

—

—

—

449D514G16

Obsolete—contact Eaton

—

14.4 kV RBA-800 rear connected mountings

—

—

—

449D515A01

RDB8-DL

449D515A01

—

RDB8

—

720

449D515G01

Obsolete—contact Eaton

—

4.8/7.2 kV RDB-800 mounting, cap and pin 95BIL

—

—

—

449D515G02

Obsolete—contact Eaton

—

15 kV RBA-800 mounting, cap and pin 110BIL

—

—

—

449D515G03

Obsolete—contact Eaton

—

23 kV RDB-800 mounting, cap and pin 150BIL

—

—

—

449D515G04

Obsolete—contact Eaton

—

34.5 kV RDB-800 mounting, cap and pin 200BIL

—

—

—

449D515G05

Obsolete—contact Eaton

—

4.8/7.2 kV RDB-800 mounting, cap and pin110BIL

—

—

—

449D515G06

Obsolete—contact Eaton

—

15 kV RBA-800 mounting, cap and pin 150BIL

—

—

—

449D515G07

Obsolete—contact Eaton

—

23 kV RDB-800 mounting, cap and pin 200BIL

—

—

—

449D515G08

Obsolete—contact Eaton

—

34.5 kV RDB-800 mounting, cap and pin 250BIL

—

—

—

449D515G09

8RBB8-VM

449D515G09

—

RDB8

8.3

720

449D515G10

15RBB8-VM

449D515G10

—

RDB8

15.5

7230

449D515G11

25RBB8-VM

449D515G11

—

RDB8

25.5

540

449D515G12

38RBB8-VM

449D515G12

—

RDB8

38

540

449D515G13

8RBB8H-VM

449D515G13

—

RDB8

8.3

720

449D515G14

15RBB8-HVM

449D515G14

—

RDB8

15.5

7230

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-61

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

449D515G15

25RBB8-HVM

449D515G15

—

RDB8

25.5

540

449D515G16

38RBB8-HVM

449D515G16

—

RDB8

38

540

449D595G01

5CLE-750E

449D595G01

—

CLE

5.5

750E

449D595G02

5CLE-600E

449D595G02

—

CLE

5.5

600E

449D595G03

Obsolete—contact Eaton

—

1/2 5CLE-1350E

—

—

—

449D595G04

Obsolete—contact Eaton

—

1/2 5CLE-1100E

—

—

—

449D597G01

5ACLS-30

449D597G01

—

CLS

5.08

30

449D597G02

5ACLS-2R

449D597G02

—

CLS

5.08

2R(70)

449D597G03

5ACLS-3R

449D597G03

—

CLS

5.08

3R(100)

449D597G04

5ACLS-4R

449D597G04

—

CLS

5.08

4R(130)

449D597G05

5ACLS-5R

449D597G05

—

CLS

5.08

5R(150)

449D597G06

5ACLS-6R

449D597G06

—

CLS

5.08

6R(170)

449D598G01

Obsolete—contact Eaton

—

8CLB-80C

—

—

—

449D598G02

Obsolete—contact Eaton

—

8CLB-100C

—

—

—

449D598G03

Obsolete—contact Eaton

—

8CLB-125C

—

—

—

449D635G01

8CLE-30E

5981C31G05

—

CLE

8.3

30E

449D635G02

8CLE-40E

5981C17G04

—

CLE

8.3

40E

449D635G03

8CLE-50E

5981C17G05

—

CLE

8.3

50E

449D635G04

8CLE-65E

5981C17G06

—

CLE

8.3

65E

449D635G05

8CLE-80E

5981C17G07

—

CLE

8.3

80E

449D635G06

8CLE-100E

5981C17G08

—

CLE

8.3

100E

449D635G07

8CLE-125E

5981C17G09

—

CLE

8.3

125E

449D636G01

8CLE-150E

5981C17G10

—

CLE

8.3

150E

449D636G02

8CLE-125E

5981C17G09

—

CLE

8.3

125E

449D636G04

8CLE-100E

5981C17G08

—

CLE

8.3

100E

449D671A07

8RBT2-20E

449D671A07

—

RBA2

8.3

20E

449D671A08

8RBT2-25E

449D671A08

—

RBA2

8.3

25E

449D671A09

8RBT2-30E

449D671A09

—

RBA2

8.3

30E

449D671A10

8RBT2-40E

449D671A10

—

RBA2

8.3

40E

449D671A11

8RBT2-50E

449D671A11

—

RBA2

8.3

50E

449D671A12

8RBT2-65E

449D671A12

—

RBA2

8.3

65E

449D671A13

8RBT2-80E

449D671A13

—

RBA2

8.3

80E

449D671A14

8RBT2-100E

449D671A14

—

RBA2

8.3

100E

449D671A15

8RBT2-125E

449D671A15

—

RBA2

8.3

125E

449D671A16

8RBT2-150E

449D671A16

—

RBA2

8.3

150E

449D671A18

8RBT2-200E

449D671A18

—

RBA2

8.3

200E

449D671A27

15RBT2-20E

449D671A27

—

RBA2

15.5

20E

449D671A28

15RBT2-25E

449D671A28

—

RBA2

15.5

25E

449D671A29

15RBT2-30E

449D671A29

—

RBA2

15.5

30E

449D671A30

15RBT2-40E

449D671A30

—

RBA2

15.5

40E

449D671A31

15RBT2-50E

449D671A31

—

RBA2

15.5

50E

449D671A32

15RBT2-65E

449D671A32

—

RBA2

15.5

65E

449D671A33

15RBT2-80E

449D671A33

—

RBA2

15.5

80E

449D671A34

15RBT2-100E

449D671A34

—

RBA2

15.5

100E

449D671A35

15RBT2-125E

449D671A35

—

RBA2

15.5

125E

449D671A36

15RBT2-150E

449D671A36

—

RBA2

15.5

150E

449D671A38

15RBT2-200E

449D671A38

—

RBA2

15.5

200E

449D671A47

25RBT2-20E

449D671A47

—

RBA2

25.5

20E

449D671A48

25RBT2-25E

449D671A48

—

RBA2

25.5

25E

449D671A49

25RBT2-30E

449D671A49

—

RBA2

25.5

30E

449D671A50

25RBT2-40E

449D671A50

—

RBA2

25.5

40E

449D671A51

25RBT2-50E

449D671A51

—

RBA2

25.5

50E

449D671A52

25RBT2-65E

449D671A52

—

RBA2

25.5

65E

V14-A2-62

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current
Rating
Amperes

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

449D671A53

25RBT2-80E

449D671A53

449D671A54

25RBT2-100E

449D671A54

—

RBA2

25.5

80E

—

RBA2

25.5

449D671A55

25RBT2-125E

100E

449D671A55

—

RBA2

25.5

449D671A56

125E

25RBT2-150E

449D671A56

—

RBA2

25.5

150E

449D671A58

25RBT2-200E

449D671A58

—

RBA2

25.5

200E

449D671A67

38RBT2-20E

449D671A67

—

RBA2

38

20E

449D671A68

38RBT2-25E

449D671A68

—

RBA2

38

25E

449D671A69

38RBT2-30E

449D671A69

—

RBA2

38

30E

449D671A70

38RBT2-40E

449D671A70

—

RBA2

38

40E

449D671A71

38RBT2-50E

449D671A71

—

RBA2

38

50E

449D671A72

38RBT2-65E

449D671A72

—

RBA2

38

65E

449D671A73

38RBT2-80E

449D671A73

—

RBA2

38

80E

449D671A74

38RBT2-100E

449D671A74

—

RBA2

38

100E

449D671A75

38RBT2-125E

449D671A75

—

RBA2

38

125E

449D671A76

38RBT2-150E

449D671A76

—

RBA2

38

150E

449D671A78

38RBT2-200E

449D671A78

—

RBA2

38

200E

449D672A07

8RBT4-20E

5982C49A07

—

RBA4

8.3

20E

449D672A08

8RBT4-25E

5982C49A08

—

RBA4

8.3

25E

449D672A09

8RBT4-30E

5982C49A09

—

RBA4

8.3

30E

449D672A10

8RBT4-40E

5982C49A10

—

RBA4

8.3

40E

449D672A11

8RBT4-50E

5982C49A11

—

RBA4

8.3

50E

449D672A12

8RBT4-65E

5982C49A12

—

RBA4

8.3

65E

449D672A13

8RBT4-80E

5982C49A13

—

RBA4

8.3

80E

449D672A14

8RBT4-100E

5982C49A14

—

RBA4

8.3

100E

449D672A15

8RBT4-125E

5982C49A15

—

RBA4

8.3

125E

449D672A16

8RBT4-150E

5982C49A16

—

RBA4

8.3

150E

449D672A18

8RBT4-200E

5982C49A18

—

RBA4

8.3

200E

449D672A19

8RBT4-250E

5982C49A19

—

RBA4

8.3

250E

449D672A20

8RBT4-300E

5982C49A20

—

RBA4

8.3

300E

449D672A21

8RBT4-400E

5982C49A21

—

RBA4

8.3

400E

449D672A32

15RBT4-20E

5982C49A32

—

RBA4

15.5

20E

449D672A33

15RBT4-25E

5982C49A33

—

RBA4

15.5

25E

449D672A34

15RBT4-30E

5982C49A34

—

RBA4

15.5

30E

449D672A35

15RBT4-40E

5982C49A35

—

RBA4

15.5

40E

449D672A36

15RBT4-50E

5982C49A36

—

RBA4

15.5

50E

449D672A37

15RBT4-65E

5982C49A37

—

RBA4

15.5

65E

449D672A38

15RBT4-80E

5982C49A38

—

RBA4

15.5

80E

449D672A39

15RBT4-100E

5982C49A39

—

RBA4

15.5

100E

449D672A40

15RBT4-125E

5982C49A40

—

RBA4

15.5

125E

449D672A41

15RBT4-150E

5982C49A41

—

RBA4

15.5

150E

449D672A43

15RBT4-200E

5982C49A43

—

RBA4

15.5

200E

449D672A44

15RBT4-250E

5982C49A44

—

RBA4

15.5

250E

449D672A45

15RBT4-300E

5982C49A45

—

RBA4

15.5

300E

449D672A46

15RBT4-400E

5982C49A46

—

RBA4

15.5

400E

449D672A57

25RBT4-20E

5982C49A57

—

RBA4

25.5

20E

449D672A58

25RBT4-25E

5982C49A58

—

RBA4

25.5

25E

449D672A59

25RBT4-30E

5982C49A59

—

RBA4

25.5

30E

449D672A60

25RBT4-40E

5982C49A60

—

RBA4

25.5

40E

449D672A61

25RBT4-50E

5982C49A61

—

RBA4

25.5

50E

449D672A62

25RBT4-65E

5982C49A62

—

RBA4

25.5

65E

449D672A63

25RBT4-80E

5982C49A63

—

RBA4

25.5

80E

449D672A64

25RBT4-100E

5982C49A64

—

RBA4

25.5

100E

449D672A65

25RBT4-125E

5982C49A65

—

RBA4

25.5

125E

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-63

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

449D672A66

25RBT4-150E

5982C49A66

449D672A68

25RBT4-200E

5982C49A68

—

RBA4

25.5

150E

—

RBA4

25.5

449D672A69

25RBT4-250E

200E

5982C49A69

—

RBA4

25.5

449D672A70

250E

25RBT4-300E

5982C49A70

—

RBA4

25.5

300E

449D672A82

38RBT4-20E

5982C49A82

—

RBA4

38

20E

449D672A83

38RBT4-25E

5982C49A83

—

RBA4

38

25E

449D672A84

38RBT4-30E

5982C49A84

—

RBA4

38

30E

449D672A85

38RBT4-40E

5982C49A85

—

RBA4

38

40E

449D672A86

38RBT4-50E

5982C49A86

—

RBA4

38

50E

449D672A87

38RBT4-65E

5982C49A87

—

RBA4

38

65E

449D672A88

38RBT4-80E

5982C49A88

—

RBA4

38

80E

449D672A89

38RBT4-100E

5982C49A89

—

RBA4

38

100E

449D672A90

38RBT4-125E

5982C49A90

—

RBA4

38

125E

449D672A91

38RBT4-150E

5982C49A91

—

RBA4

38

150E

449D672A93

38RBT4-200E

5982C49A93

—

RBA4

38

200E

449D672A94

38RBT4-250E

5982C49A94

—

RBA4

38

250E

449D672A95

38RBT4-300E

5982C49A95

—

RBA4

38

300E

449D689G03

Obsolete—contact Eaton

—

1000V SCL 600A fuse

—

—

—

449D689G04

Obsolete—contact Eaton

—

1000V SCL 600A fuse

—

—

—

449D689G05

Obsolete—contact Eaton

—

1000V SCL 800A fuse

—

—

—

449D759G01

5CLS-2R

151D241G02

—

CLS

5.08

2R(70)

449D759G02

5CLS-3R

151D241G03

—

CLS

5.08

3R(100)

449D759G03

5CLS-4R

151D241G04

—

CLS

5.08

4R(130)

449D759G04

5CLS-5R

151D241G05

—

CLS

5.08

5R(150)

449D759G05

5CLS-6R

151D241G06

—

CLS

5.08

6R(170)

449D759G06

5CLS-9R

151D961G01

—

CLS

5.08

9R(200)

449D759G07

5CLS-12R

151D961G02

—

CLS

5.08

12R(230)

449D759G08

5CLS-30

151D241G02

—

CLS

5.08

30

449D760G01

5CLS-18R

151D961G03

—

CLS

5.08

18R(390)

449D760G02

5CLS-24R

151D961G04

—

CLS

5.08

24R(450)

449D795G01

Obsolete—contact Eaton

—

4.8/7.2 kV RDB2 45 mounting, cap and pin

—

—

—

449D795G02

Obsolete—contact Eaton

—

14.4 kV RDB2 45 mounting, cap and pin

—

—

—

449D795G03

Obsolete—contact Eaton

—

23 kV RDB2 45 mounting, cap and pin

—

—

—

449D795G04

Obsolete—contact Eaton

—

34.5 kV RDB2 45 mounting, cap and pin

—

—

—

449D795G06

Obsolete—contact Eaton

—

4.8/7.2 kV RDB2 45 mounting, station post

—

—

—

449D795G07

Obsolete—contact Eaton

—

14.4 kV RDB2 45 mounting, station post

—

—

—

449D795G08

Obsolete—contact Eaton

—

23 kV RDB2 45 mounting, station post

—

—

—

449D795G09

Obsolete—contact Eaton

—

34.5 kV RDB2 45 mounting, station post

—

—

—

449D795G11

Obsolete—contact Eaton

—

4.8/7.2 kV RDB4 45 mounting, cap and pin

—

—

—

449D795G12

Obsolete—contact Eaton

—

14.4 kV RDB4 45 mounting, cap and pin

—

—

—

449D795G13

Obsolete—contact Eaton

—

23 kV RDB4 45 mounting, cap and pin

—

—

—

449D795G14

Obsolete—contact Eaton

—

34.5 kV RDB4 45 mounting, cap and pin

—

—

—

449D795G16

Obsolete—contact Eaton

—

4.8/7.2 kV RDB4 45 mounting, station post

—

—

—

449D795G17

Obsolete—contact Eaton

—

14.4 kV RDB4 45 mounting, station post

—

—

—

449D795G18

Obsolete—contact Eaton

—

23 kV RDB4 45 mounting, station post

—

—

—

449D795G19

Obsolete—contact Eaton

—

34.5 kV RDB4 45 mounting, station post

—

—

—

449D796G01

Obsolete—contact Eaton

—

4.8/7.2 kV RDB2 90 mounting, cap and pin

—

—

—

449D796G02

Obsolete—contact Eaton

—

14.4 kV RDB2 90 mounting, cap and pin

—

—

—

449D796G03

Obsolete—contact Eaton

—

23 kV RDB2 90 mounting, cap and pin

—

—

—

449D796G04

Obsolete—contact Eaton

—

34.5 kV RDB2 90 mounting, cap and pin

—

—

—

449D796G06

Obsolete—contact Eaton

—

4.8/7.2 kV RDB2 90 mounting, station post

—

—

—

449D796G07

Obsolete—contact Eaton

—

14.4 kV RDB2 90 mounting, station post

—

—

—

449D796G08

Obsolete—contact Eaton

—

23 kV RDB2 90 mounting, station post

—

—

—

V14-A2-64

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

449D796G09

Obsolete—contact Eaton

—

449D796G11

Obsolete—contact Eaton

—

34.5 kV RDB2 90 mounting, station post

—

—

—

4.8/7.2 kV RDB4 90 mounting, cap and pin

—

—

449D796G12

Obsolete—contact Eaton

—

—

14.4 kV RDB4 90 mounting, cap and pin

—

—

—

449D796G13
449D796G14

Obsolete—contact Eaton

—

23 kV RDB4 90 mounting, cap and pin

—

—

—

Obsolete—contact Eaton

—

34.5 kV RDB4 90 mounting, cap and pin

—

—

—

449D796G16

Obsolete—contact Eaton

—

4.8/7.2 kV RDB4 90 mounting, station post

—

—

—

449D796G17

Obsolete—contact Eaton

—

14.4 kV RDB4 90 mounting, station post

—

—

—

449D796G18

Obsolete—contact Eaton

—

23 kV RDB4 90 mounting, station post

—

—

—

449D796G19

Obsolete—contact Eaton

—

34.5 kV RDB4 90 mounting, station post

—

—

—

449D797G01

2CLE-25E

449D797G01

—

CLE

2.75

25E

449D797G02

2CLE-30E

449D797G02

—

CLE

2.75

30E

449D797G03

2CLE-50E

449D797G03

—

CLE

2.75

50E

449D797G04

2CLE-65E

449D797G04

—

CLE

2.75

65E

449D797G05

2CLE-80E

449D797G05

—

CLE

2.75

80E

449D797G06

2CLE-100E

449D797G06

—

CLE

2.75

100E

449D797G07

2CLE-125E

449D797G07

—

CLE

2.75

125E

449D797G08

2CLE-150E

449D797G08

—

CLE

2.75

150E

449D797G09

2CLE-200E

449D797G09

—

CLE

2.75

200E

449D797G10

Obsolete—contact Eaton

—

2CLE-225E

—

—

—

449D797G11

2CLE-10E

449D797G11

—

CLE

2.75

10E

449D797G12

2CLE-40E

449D797G12

—

CLE

2.75

40E

449D797G13

2CLE-250E

449D797G13

—

CLE

2.75

250E

449D797G14

2CLE-300E

449D797G14

—

CLE

2.75

300E

449D797G15

2CLE-350X

449D797G15

—

CLE

2.75

350X

449D797G17

2CLE-400X

449D797G17

—

CLE

2.75

400X

449D797G18

2CLE-450X

449D797G18

—

CLE

2.75

450X

449D926G01

5HCLS-2R

151D240G02

—

CLS

5.08

2R(70)

449D926G02

5HCLS-3R

151D240G03

—

CLS

5.08

3R(100)

449D926G03

5HCLS-4R

151D240G04

—

CLS

5.08

4R(130)

449D926G04

5HCLS-5R

151D240G05

—

CLS

5.08

5R(150)

449D926G05

5HCLS-6R

151D240G06

—

CLS

5.08

6R(170)

449D926G06

5HCLS-9R

151D962G01

—

CLS

5.08

9R(200)

449D926G07

5HCLS-12R

151D962G02

—

CLS

5.08

12R(230)

449D926G08

5HCLS-30

151D240G01

—

CLS

5.08

30

449D935G01

5HCLS-18R

151D962G03

—

CLS

5.08

18R(390)

449D935G02

5HCLS-24R

151D962G04

—

CLS

5.08

24R(450)

502B206G01

Obsolete—contact Eaton

—

Adaptor kit

—

—

—

502B206G02

Obsolete—contact Eaton

—

Adaptor kit

—

—

—

502B206G03

Obsolete—contact Eaton

—

Adaptor kit

—

—

—

505D420G01

8DBA1-3E

505D420G01

—

DBA1

8.3

3

505D420G02

15DBA1-3E

505D420G02

—

DBA1

15.5

3

505D420G03

25DBA1-3E

505D420G03

—

DBA1

25.5

3

505D420G04

38DBA1-3E

505D420G04

—

DBA1

38

3

505D420G05

48DBA1-3E

505D420G05

—

DBA1

48

3

505D420G06

72DBA1-3E

505D420G06

—

DBA1

72

3

505D420G07

38DBA2-3E

505D420G07

—

DBA2

38

3

505D420G08

48DBA2-3E

505D420G08

—

DBA2

48

3

505D420G09

72DBA2-3E

505D420G09

—

DBA2

72

3

505D615A01

Obsolete—contact Eaton

—

BA-400 live parts

—

—

—

505D615A02

Obsolete—contact Eaton

—

BA-400 live parts

—

—

—

505D615A03

Obsolete—contact Eaton

—

BA-400 live parts

—

—

—

505D615A04

Obsolete—contact Eaton

—

BA-400 live parts

—

—

—

505D615A05

Obsolete—contact Eaton

—

BA-400 live parts

—

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-65

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

505D615A06

Obsolete—contact Eaton

—

505D615A07

Obsolete—contact Eaton

—

BA-400 live parts

—

—

—

BA-400 live parts

—

—

505D615A08

Obsolete—contact Eaton

—

—

BA-400 live parts

—

—

505D615A09

—

Obsolete—contact Eaton

—

BA-400 live parts

—

—

—

505D615A10

Obsolete—contact Eaton

—

BA-400 live parts

—

—

—

505D616A01

Obsolete—contact Eaton

—

BA-200 live parts

—

—

—

505D620A01

Obsolete—contact Eaton

—

BA-200 live parts

—

—

—

505D620A02

Obsolete—contact Eaton

—

BA-200 live parts

—

—

—

505D620A03

Obsolete—contact Eaton

—

BA-200 live parts

—

—

—

505D620A04

Obsolete—contact Eaton

—

BA-200 live parts

—

—

—

505D620A05

Obsolete—contact Eaton

—

BA-200 live parts

—

—

—

505D620A06

Obsolete—contact Eaton

—

BA-200 live parts

—

—

—

505D620A07

Obsolete—contact Eaton

—

BA-200 live parts

—

—

—

505D620A08

Obsolete—contact Eaton

—

BA-200 live parts

—

—

—

565D990A02

2CLS-2R

591C812G02

—

CLS

2.54

2R(70)

565D990A04

2CLS-4R

591C812G04

—

CLS

2.54

4R(130)

565D990A06

2CLS-6R

591C812G06

—

CLS

2.54

6R(170)

565D990A09

2CLS-9R

591C812G07

—

CLS

2.54

9R(200)

565D990A12

2CLS-12R

591C812G08

—

CLS

2.54

12R(230)

565D990A15

5CLS-2R

151D241G02

—

CLS

5.08

2R(70)

565D990A17

5CLS-4R

151D241G04

—

CLS

5.08

4R(130)

565D990A19

5CLS-6R

151D241G06

—

CLS

5.08

6R(170)

565D990A22

5CLS-9R

151D962G01

—

CLS

5.08

9R(200)

565D990A25

5CLS-12R

151D962G02

—

CLS

5.08

12R(230)

565C991A04

8BA2-10E

117D123A04

—

BA2

8.3

10E

565C991A05

8BA2-15E

117D123A05

—

BA2

8.3

15E

565C991A06

8BA2-20E

117D123A06

—

BA2

8.3

20E

565C991A07

8BA2-25E

117D123A07

—

BA2

8.3

25E

565C991A08

8BA2-30E

117D123A08

—

BA2

8.3

30E

565C991A09

8BA2-40E

117D123A09

—

BA2

8.3

40E

565C991A11

8BA2-65E

117D123A11

—

BA2

8.3

65E

565C991A12

8BA2-80E

117D123A12

—

BA2

8.3

80E

565C991A13

8BA2-100E

117D123A13

—

BA2

8.3

100E

565C991A15

8BA2-150E

117D123A15

—

BA2

8.3

150E

565C991A16

8BA2-200E

117D123A16

—

BA2

8.3

200E

565C991A21

15BA2-15E

117D123A21

—

BA2

15.5

15E

565C991A23

15BA2-25E

117D123A23

—

BA2

15.5

25E

565C991A24

15BA2-30E

117D123A24

—

BA2

15.5

30E

565C991A26

15BA2-50E

117D123A26

—

BA2

15.5

50E

565C991A27

15BA2-65E

117D123A27

—

BA2

15.5

65E

565C991A28

15BA2-80E

117D123A28

—

BA2

15.5

80E

565C991A31

15BA2-150E

117D123A31

—

BA2

15.5

150E

565C991A32

15BA2-200E

117D123A32

—

BA2

15.5

200E

565D993A11

8BA4-65E

116D977A11

—

BA4

8.3

65E

565D993A12

8BA4-80E

116D977A12

—

BA4

8.3

80E

565D993A13

8BA4-100E

116D977A13

—

BA4

8.3

100E

565D993A14

8BA4-125E

116D977A14

—

BA4

8.3

125E

565D993A16

8BA4-200E

116D977A16

—

BA4

8.3

200E

565D993A17

8BA4-250E

116D977A17

—

BA4

8.3

250E

565D993A18

8BA4-300E

116D977A18

—

BA4

8.3

300E

565D993A19

8BA4-400E

116D977A19

—

BA4

8.3

400E

565D993A21

15BA4-5E

116D977A22

—

BA4

15.5

5E

565D993A25

15BA4-20E

116D977A26

—

BA4

15.5

20E

V14-A2-66

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

565D993A27

15BA4-30E

116D977A28

565D993A28

15BA4-40E

116D977A29

—

BA4

15.5

30E

—

BA4

15.5

565D993A30

15BA4-65E

40E

116D977A31

—

BA4

15.5

565D993A31

65E

15BA4-80E

116D977A32

—

BA4

15.5

80E

565D993A32

15BA4-100E

116D977A33

—

BA4

15.5

100E

565D993A33

15BA4-125E

116D977A34

—

BA4

15.5

125E

565D993A34

15BA4-150E

116D977A35

—

BA4

15.5

150E

565D993A36

15BA4-250E

116D977A37

—

BA4

15.5

250E

565D993A37

15BA4-300E

116D977A38

—

BA4

15.5

300E

565D993A48

15BA4-400E

116D977A39

—

BA4

15.5

400E

566C137A25

15CLE-80E

5981C19G07

—

CLE

15.5

80E

566C137A26

15CLE-100E

5981C19G08

—

CLE

15.5

100E

5809A21G01

CLPT-DLC

—

—

—

—

—

591C142G01

2ACLS-25

591C142G01

—

CLS

2.54

25

591C142G02

2ACLS-2R

591C142G02

—

CLS

2.54

2R(70)

591C142G03

2ACLS-3R

591C142G03

—

CLS

2.54

3R(100)

591C142G04

2ACLS-4R

591C142G04

—

CLS

2.54

4R(130)

591C142G05

2ACLS-5R

591C142G05

—

CLS

2.54

5R(150)

591C142G06

2ACLS-6R

591C142G06

—

CLS

2.54

6R(170)

591C142G07

2ACLS-9R

591C142G07

—

CLS

2.54

9R(200)

591C142G08

2ACLS-12R

591C142G08

—

CLS

2.54

12R(230)

591C143G01

2ACLS-18R

591C143G01

—

CLS

2.54

18R(390)

591C143G02

2ACLS-24R

591C143G02

—

CLS

2.54

24R(450)

591C144G02

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-200 rear con. live parts

—

—

—

591C144G03

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-200 rear con. live parts

—

—

—

591C144G04

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-200 rear con. live parts

—

—

—

591C144G06

Obsolete—contact Eaton

—

13.8 kV RBA-200 rear con. live parts

—

—

—

591C144G07

Obsolete—contact Eaton

—

13.8 kV RBA-200 rear con. live parts

—

—

—

591C144G08

Obsolete—contact Eaton

—

13.8 kV RBA-200 rear con. live parts

—

—

—

591C144G10

Obsolete—contact Eaton

—

14.4 kV RBA-200 rear con. live parts

—

—

—

591C144G11

Obsolete—contact Eaton

—

14.4 kV RBA-200 rear con. live parts

—

—

—

591C144G12

Obsolete—contact Eaton

—

14.4 kV RBA-200 rear con. live parts

—

—

—

591C144G17

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-200 rear con. live parts

—

—

—

591C144G18

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-200 rear con. live parts

—

—

—

591C144G19

Obsolete—contact Eaton

—

2.4/7.2 kV RBA-200 rear con. live parts

—

—

—

591C144G21

Obsolete—contact Eaton

—

13.8 kV RBA-200 rear con. live parts

—

—

—

591C144G22

Obsolete—contact Eaton

—

13.8 kV RBA-200 rear con. live parts

—

—

—

591C144G23

Obsolete—contact Eaton

—

13.8 kV RBA-200 rear con. live parts

—

—

—

591C144G25

Obsolete—contact Eaton

—

14.4/23 kV RBA-200 rear con. live parts

—

—

—

591C144G26

Obsolete—contact Eaton

—

14.4/23 kV RBA-200 rear con. live parts

—

—

—

591C144G27

Obsolete—contact Eaton

—

14.4/23 kV RBA-200 rear con. live parts

—

—

—

591C152G01

Obsolete—contact Eaton

—

8CLB-30C

—

—

—

591C152G02

Obsolete—contact Eaton

—

8CLB-45C

—

—

—

591C152G03

Obsolete—contact Eaton

—

8CLB-60C

—

—

—

591C154G01

Obsolete—contact Eaton

—

2.4 kV CLS-13 25 fuse

—

—

—

591C154G02

Obsolete—contact Eaton

—

2.4 kV CLS-13 2R fuse

—

—

—

591C154G03

Obsolete—contact Eaton

—

2.4 kV CLS-13 3R fuse

—

—

—

591C154G04

Obsolete—contact Eaton

—

2.4 kV CLS-13 4R fuse

—

—

—

591C154G05

Obsolete—contact Eaton

—

2.4 kV CLS-13 5R fuse

—

—

—

591C154G06

Obsolete—contact Eaton

—

2.4 kV CLS-13 6R fuse

—

—

—

591C154G07

Obsolete—contact Eaton

—

2.4 kV CLS-13 9R fuse

—

—

—

591C154G08

Obsolete—contact Eaton

—

2.4 kV CLS-13 12R fuse

—

—

—

591C155G01

2HCLS-25

591C155G01

—

CLS

2.54

25

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-67

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

591C155G02

2HCLS-2R

591C155G02

591C155G03

2HCLS-3R

591C155G03

—

CLS

2.54

2R(70)

—

CLS

2.54

591C155G04

2HCLS-4R

3R(100)

591C155G04

—

CLS

2.54

591C155G05

4R(130)

2HCLS-5R

591C155G05

—

CLS

2.54

5R(150)

591C155G06

2HCLS-6R

591C155G06

—

CLS

2.54

6R(170)

591C155G07

2HCLS-9R

591C155G07

—

CLS

2.54

9R(200)

591C155G08

2HCLS-12R

591C155G08

—

CLS

2.54

12R(230)

591C156G01

Obsolete—contact Eaton

—

2.4 kV CLS-13 18R fuse

—

—

—

591C156G02

Obsolete—contact Eaton

—

2.4 kV CLS-13 24R fuse

—

—

—

591C157G01

2HCLS-18R

591C157G01

—

CLS

2.54

18R(390)

591C157G02

2HCLS-24R

591C157G02

—

CLS

2.54

24R(450)

591C162G01

15CLT-30

9570D10G01

—

CLT

15.5

30

591C163G05

Obsolete—contact Eaton

—

8.3 kV 15A FDL fuse

—

—

—

591C163G06

Obsolete—contact Eaton

—

17.1 kV 15A FDL fuse

—

—

—

591C163G07

Obsolete—contact Eaton

—

8.3 kV 25A FDL fuse

—

—

—
—

591C163G10

Obsolete—contact Eaton

—

8.3 kV 40A FDL fuse

—

—

591C172G01

CLS700-DUMMY

591C172G01

—

CLS

5.08

—

591C240G02

Obsolete

—

23CLTB-18

—

—

—

591C248G02

8NCLPT-5E

591C248G02

—

NCLPT

8.3

5E

591C248G07

8NCLPT-1E

591C248G07

—

NCLPT

8.3

1E

591C252G03

8NCLPT-8E

591C252G03

—

NCLPT

8.3

8E

591C254G01

Obsolete—contact Eaton

—

8.3 kV 5A CLTS fuse

—

—

—

591C254G02

Obsolete—contact Eaton

—

8.3 kV 8A CLTS fuse

—

—

—

591C254G03

Obsolete—contact Eaton

—

8.3 kV 12A CLTS fuse

—

—

—

591C254G04

Obsolete—contact Eaton

—

8.3 kV 18A CLTS fuse

—

—

—

591C273G03

8CLT-12

591C273G03

—

CLT

8.3

12

591C358G01

8RBA8-INH

5981C54G01

—

RBA8

8.3

720

591C358G02

15RBA8-INH

5981C54G02

—

RBA8

15.5

720

591C358G03

25RBA8-INH

5981C54G03

—

RBA8

25.5

540

591C358G04

38RBA8-INH

5981C54G04

—

RBA8

38

540

591C376G01

15CLE-175E

5981C25G01

—

CLE

15.5

175E

591C376G02

15CLE-150E

5981C19G10

—

CLE

15.5

150E

591C404G01

Obsolete—contact Eaton

—

8CLTB-18

—

—

—

591C607G01

RBA4-FLTR

591C607G01

(3 pack)

RBA4

—

—

591C607G02

RBA4-FLTR-HC

591C607G02

(3 pack)

RBA4

—

—

591C607G03

RBA4-FLTR

591C607G03

(1 pack)

RBA4

—

—

591C607G04

RBA4-FLTR-HC

591C607G04

(1 pack)

RBA4

—

—

591C812G01

2CLS-25

591C812G01

—

CLS

2.54

25

591C812G02

2CLS-2R

591C812G02

—

CLS

2.54

2R(70)

591C812G03

2CLS-3R

591C812G03

—

CLS

2.54

3R(100)

591C812G04

2CLS-4R

591C812G04

—

CLS

2.54

4R(130)

591C812G05

2CLS-5R

591C812G05

—

CLS

2.54

5R(150)

591C812G06

2CLS-6R

591C812G06

—

CLS

2.54

6R(170)

591C812G07

2CLS-9R

591C812G07

—

CLS

2.54

9R(200)

591C812G08

2CLS-12R

591C812G08

—

CLS

2.54

12R(230)

591C813G01

2CLS-18R

591C813G01

—

CLS

2.54

18R(390)

591C813G02

2CLS-24R

591C813G02

—

CLS

2.54

24R(450)

592C250G01

317A487H04

7186A29G14

—

NCLPT

5.5

3E

595C204G04

CLE-DF-E

9078A63G04

—

CLE

—

450

5978C31G01

PF8-30

5978C31G01

—

EMOLD

—

—

5978C62G01

4CX-18C

5978C62G01

—

CX

4.3

18C

5978C62G02

4XC-25C

5978C62G02

—

CX

4.3

25C

5978C62G03

4CX-35C

5978C62G03

—

CX

4.3

35C

V14-A2-68

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5978C62G04

8CX-4.5C

5978C62G04

5978C62G05

8CX-6C

5978C62G05

—

CX

8.3

4.5C

—

CX

8.3

5978C62G06

8CX-8C

6C

5978C62G06

—

CX

8.3

5978C62G21

8C

4CXI-18C

5978C62G21

—

CX

4.3

18C

5978C62G22

4XC-25C

5978C62G22

—

CX

4.3

25C

5978C62G23

4CXI-35C

5978C62G23

—

CX

4.3

35C

5978C62G24

8CXI-4.5C

5978C62G24

—

CX

8.3

4.5C

5978C62G25

8CXI-6C

5978C62G25

—

CX

8.3

6C

5978C62G26

8CXI-8C

5978C62G26

—

CX

8.3

8C

5978C66G01

4XC-45C

5978C66G01

—

CX

4.3

45C

5978C66G02

4CX-50C

5978C66G02

—

CX

4.3

50C

5978C66G03

4CX-65C

5978C66G03

—

CX

4.3

65C

5978C66G04

4CX-75C

5978C66G04

—

CX

4.3

75C

5978C66G05

4CX-100C

5978C66G05

—

CX

4.3

100C

5978C66G21

4XC-45C

5978C66G21

—

CX

4.3

45C

5978C66G22

4CXI-50C

5978C66G22

—

CX

4.3

50C

5978C66G23

4CXI-65C

5978C66G23

—

CX

4.3

65C

5978C66G24

4CXI-75C

5978C66G24

—

CX

4.3

75C

5978C66G25

4CXI-100C

5978C66G25

—

CX

4.3

100C

5978C70G01

5CX-18C

5978C70G01

—

CX

5.5

18C

5978C70G02

5CX-20C

5978C70G02

—

CX

5.5

20C

5978C70G03

5CX-25C

5978C70G03

—

CX

5.5

25C

5978C70G04

5CX-30C

5978C70G04

—

CX

5.5

30C

5978C70G05

5CX-40C

5978C70G05

—

CX

5.5

40C

5978C70G06

5CX-50C

5978C70G06

—

CX

5.5

50C

5978C70G07

5CX-65C

5978C70G07

—

CX

5.5

65C

5978C70G08

5CX-75C

5978C70G08

—

CX

5.5

75C

5978C70G21

5CXI-18C

5978C70G21

—

CX

5.5

18C

5978C70G22

5CXI-20C

5978C70G22

—

CX

5.5

20C

5978C70G23

5CXI-25C

5978C70G23

—

CX

5.5

25C

5978C70G24

5CXI-30C

5978C70G24

—

CX

5.5

30C

5978C70G25

5CXI-40C

5978C70G25

—

CX

5.5

40C

5978C70G26

5CXI-50C

5978C70G26

—

CX

5.5

50C

5978C70G27

5CXI-65C

5978C70G27

—

CX

5.5

65C

5978C70G28

5CXI-75C

5978C70G28

—

CX

5.5

75C

5978C72G01

8CX-18C

5978C72G01

—

CX

8.3

18C

5978C72G02

8CX-20C

5978C72G02

—

CX

8.3

20C

5978C72G03

8CX-25C

5978C72G03

—

CX

8.3

25C

5978C72G04

8CX-30C

5978C72G04

—

CX

8.3

30C

5978C72G05

8CX-40C

5978C72G05

—

CX

8.3

40C

5978C72G21

8CXI-18C

5978C72G21

—

CX

8.3

18C

5978C72G22

8CXI-20C

5978C72G22

—

CX

8.3

20C

5978C72G23

8CXI-25C

5978C72G23

—

CX

8.3

25C

5978C72G24

8CXI-30C

5978C72G24

—

CX

8.3

30C

5978C72G25

8CXI-40C

5978C72G25

—

CX

8.3

40C

5978C92G01

17DBU-15SE

5981C77G01

—

DBU

17

15SE

5978C92G02

17DBU-20SE

5981C77G02

—

DBU

17

20SE

5978C92G03

17DBU-25SE

5981C77G03

—

DBU

17

25SE

5978C92G04

17DBU-30SE

5981C77G04

—

DBU

17

30SE

5978C92G05

17DBU-40SE

5981C77G05

—

DBU

17

40SE

5978C92G06

17DBU-50SE

5981C77G06

—

DBU

17

50SE

5978C92G07

17DBU-65SE

5981C77G07

—

DBU

17

65SE

5978C92G08

17DBU-80SE

5981C77G08

—

DBU

17

80SE

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-69

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5978C92G09

17DBU-100SE

5981C77G09

5978C92G10

17DBU-125SE

5981C77G10

—

DBU

17

100SE

—

DBU

17

5978C92G11

17DBU-150SE

125SE

5981C77G11

—

DBU

17

5978C92G12

150SE

17DBU-175SE

5981C77G12

—

DBU

17

175SE

5978C92G13

17DBU-200SE

5981C77G13

—

DBU

17

200SE

5978C92G14

Obsolete—contact Eaton

—

17DBU-1

—

—

—

5978C92G15

17DBU-3K

5981C75G01

—

DBU

17

3K

5978C92G16

17DBU-6K

5981C75G02

—

DBU

17

6K

5978C92G17

17DBU-8K

5981C75G03

—

DBU

17

8K

5978C92G18

17DBU-10K

5981C75G04

—

DBU

17

10K

5978C92G19

17DBU-12K

5981C75G05

—

DBU

17

12K

5978C92G20

17DBU-15K

5981C75G06

—

DBU

17

15K

5978C92G21

17DBU-20K

5981C75G07

—

DBU

17

20K

5978C92G22

17DBU-25K

5981C75G08

—

DBU

17

25K

5978C92G23

17DBU-30K

5981C75G09

—

DBU

17

30K

5978C92G24

17DBU-40K

5981C75G10

—

DBU

17

40K

5978C92G25

17DBU-50K

5981C75G11

—

DBU

17

50K

5978C92G26

17DBU-65K

5981C75G12

—

DBU

17

65K

5978C92G27

17DBU-80K

5981C75G13

—

DBU

17

80K

5978C92G28

17DBU-100K

5981C75G14

—

DBU

17

100K

5978C92G29

17DBU-140K

5981C75G15

—

DBU

17

140K

5978C92G30

17DBU-200K

5981C75G16

—

DBU

17

200K

5978C93G01

27DBU-15SE

5981C87G01

—

DBU

27

15SE

5978C93G02

27DBU-20SE

5981C87G02

—

DBU

27

20SE

5978C93G03

27DBU-25SE

5981C87G03

—

DBU

27

25SE

5978C93G04

27DBU-30SE

5981C87G04

—

DBU

27

30SE

5978C93G05

27DBU-40SE

5981C87G05

—

DBU

27

40SE

5978C93G06

27DBU-50SE

5981C87G06

—

DBU

27

50SE

5978C93G07

27DBU-65SE

5981C87G07

—

DBU

27

65SE

5978C93G08

27DBU-80SE

5981C87G08

—

DBU

27

80SE

5978C93G09

27DBU-100SE

5981C87G09

—

DBU

27

100SE

5978C93G10

27DBU-125SE

5981C87G10

—

DBU

27

125SE

5978C93G11

27DBU-150SE

5981C87G11

—

DBU

27

150SE

5978C93G12

27DBU-175SE

5981C87G12

—

DBU

27

175SE

5978C93G13

27DBU-200SE

5981C87G13

—

DBU

27

200SE

5978C93G14

Obsolete—contact Eaton

—

27DBU-1

—

—

—

5978C93G15

27DBU-3K

5981C85G01

—

DBU

27

3K

5978C93G16

27DBU-6K

5981C85G02

—

DBU

27

6K

5978C93G17

27DBU-8K

5981C85G03

—

DBU

27

8K

5978C93G18

27DBU-10K

5981C85G04

—

DBU

27

10K

5978C93G19

27DBU-12K

5981C85G05

—

DBU

27

12K

5978C93G20

27DBU-15K

5981C85G06

—

DBU

27

15K

5978C93G21

27DBU-20K

5981C85G07

—

DBU

27

20K

5978C93G22

27DBU-25K

5981C85G08

—

DBU

27

25K

5978C93G23

27DBU-30K

5981C85G09

—

DBU

27

30K

5978C93G24

27DBU-40K

5981C85G10

—

DBU

27

40K

5978C93G25

27DBU-50K

5981C85G11

—

DBU

27

50K

5978C93G26

27DBU-65K

5981C85G12

—

DBU

27

65K

5978C93G27

27DBU-80K

5981C85G13

—

DBU

27

80K

5978C93G28

27DBU-100K

5981C85G14

—

DBU

27

100K

5978C93G29

27DBU-140K

5981C85G15

—

DBU

27

140K

5978C93G30

27DBU-200K

5981C85G16

—

DBU

27

200K

5978C94G01

38DBU-15SE

5981C97G01

—

DBU

38

15SE

V14-A2-70

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5978C94G02

38DBU-20SE

5981C97G02

5978C94G03

38DBU-25SE

5981C97G03

—

DBU

38

20SE

—

DBU

38

5978C94G04

38DBU-30SE

25SE

5981C97G04

—

DBU

38

5978C94G05

30SE

38DBU-40SE

5981C97G05

—

DBU

38

40SE

5978C94G06

38DBU-50SE

5981C97G06

—

DBU

38

50SE

5978C94G07

38DBU-65SE

5981C97G07

—

DBU

38

65SE

5978C94G08

38DBU-80SE

5981C97G08

—

DBU

38

80SE

5978C94G09

38DBU-100SE

5981C97G09

—

DBU

38

100SE

5978C94G10

38DBU-125SE

5981C97G10

—

DBU

38

125SE

5978C94G11

38DBU-150SE

5981C97G11

—

DBU

38

150SE

5978C94G12

38DBU-175SE

5981C97G12

—

DBU

38

175SE

5978C94G13

38DBU-200SE

5981C97G13

—

DBU

38

200SE

5978C94G14

Obsolete—contact Eaton

—

38DBU-1

—

—

—

5978C94G15

38DBU-3K

5981C95G01

—

DBU

38

3K

5978C94G16

38DBU-6K

5981C95G02

—

DBU

38

6K

5978C94G17

38DBU-8K

5981C95G03

—

DBU

38

8K

5978C94G18

38DBU-10K

5981C95G04

—

DBU

38

10K

5978C94G19

38DBU-12K

5981C95G05

—

DBU

38

12K

5978C94G20

38DBU-15K

5981C95G06

—

DBU

38

15K

5978C94G21

38DBU-20K

5981C95G07

—

DBU

38

20K

5978C94G22

38DBU-25K

5981C95G08

—

DBU

38

25K

5978C94G23

38DBU-30K

5981C95G09

—

DBU

38

30K

5978C94G24

38DBU-40K

5981C95G10

—

DBU

38

40K

5978C94G25

38DBU-50K

5981C95G11

—

DBU

38

50K

5978C94G26

38DBU-65K

5981C95G12

—

DBU

38

65K

5978C94G27

38DBU-80K

5981C95G13

—

DBU

38

80K

5978C94G28

38DBU-100K

5981C95G14

—

DBU

38

100K

5978C94G29

38DBU-140K

5981C95G15

—

DBU

38

140K

5978C94G30

38DBU-200K

5981C95G16

—

DBU

38

200K

5979C20G03

Obsolete—contact Eaton

—

8.3 kV 40A CLTO fuse

—

—

—

5979C20G04

Obsolete—contact Eaton

—

8.3 kV 50A CLTO fuse

—

—

—

5979C20G05

Obsolete—contact Eaton

—

8.3 kV 65A CLTO fuse

—

—

—

5979C20G06

Obsolete—contact Eaton

—

8.3 kV 80A CLTO fuse

—

—

—

5979C20G07

Obsolete—contact Eaton

—

8.3 kV 100A CLTO fuse

—

—

—

5979C20G08

Obsolete—contact Eaton

—

8.3 kV 125A CLTO fuse

—

—

—

5979C20G12

Obsolete—contact Eaton

—

15.5 kV 40A CLTO fuse

—

—

—

5979C20G13

Obsolete—contact Eaton

—

15.5 kV 50A CLTO fuse

—

—

—

5979C20G14

Obsolete—contact Eaton

—

15.5 kV 65A CLTO fuse

—

—

—

5979C20G15

Obsolete—contact Eaton

—

15.5 kV 80A CLTO fuse

—

—

—

5979C20G16

Obsolete—contact Eaton

—

15.5 kV 100A CLTO fuse

—

—

—

5979C20G17

Obsolete—contact Eaton

—

15.5 kV 125A CLTO fuse

—

—

—

5979C20G21

Obsolete—contact Eaton

—

23 kV 40A CLTO fuse

—

—

—

5979C20G22

Obsolete—contact Eaton

—

23 kV 50A CLTO fuse

—

—

—

5979C77G01

8RBA2-INH

5981C51G01

—

RBA2

8.3

200

5979C77G02

15RBA2-INH

5981C51G02

—

RBA2

15.2

200

5979C77G03

25RBA2-INH

5981C51G03

—

RBA2

25.5

200

5979C77G04

38RBA2-INH

5981C51G04

—

RBA2

38

200

5979C77G05

5979C77G05

5979C77G05

RBA2 holder with RDB shunt

RBA2

8.3

200

5979C77G06

5979C77G06

5979C77G06

RBA2 holder with RDB shunt

RBA2

15.2

200

5979C77G07

5979C77G07

5979C77G07

RBA2 holder with RDB shunt

RBA2

25.5

200

5979C77G08

5979C77G08

5979C77G08

RBA2 holder with RDB shunt

RBA2

38

200

5979C78G01

8RBA4-INH

5981C53G01

—

RBA4

8.3

400

5979C78G02

15RBA4-INH

5981C53G02

—

RBA4

15.2

400

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-71

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

5979C78G03

25RBA4-INH

5981C53G03

—

RBA4

25.5

300

5979C78G04

38RBA4-INH

5981C53G04

—

RBA4

38

300

5979C78G05

5979C78G05

5979C78G05

RBA4 holder with RDB shunt

RBA4

8.3

400

5979C78G06

5979C78G06

5979C78G06

RBA4 holder with RDB shunt

RBA4

15.2

400

5979C78G07

5979C78G07

5979C78G07

RBA4 holder with RDB shunt

RBA4

25.5

300

5979C78G08

5979C78G08

5979C78G08

RBA4 holder with RDB shunt

RBA4

38

300

5979C79G01

8RBA8-INH

5981C54G01

—

RBA8

8.3

720

5979C79G02

15RBA8-INH

5981C54G02

—

RBA8

15.2

720

5979C79G03

25RBA8-INH

5981C54G03

—

RBA8

25.5

540

5979C79G04

38RBA8-INH

5981C54G04

—

RBA8

38

540

5979C79G05

5979C79G05

5979C79G05

RBA8 holder with RDB shunts

RBA8

8.3

720

5979C79G06

5979C79G06

5979C79G06

RBA8 holder with RDB shunts

RBA8

15.2

720

5979C79G07

5979C79G07

5979C79G07

RBA8 holder with RDB shunts

RBA8

25.5

540

5979C79G08

5979C79G08

5979C79G08

RBA8 holder with RDB shunts

RBA8

38

540

5979C91G01

7CLS70-24R

5979C91G01

—

CLS

7.2

24R(450)

5979C91G02

7CLS70-36R

5979C91G02

—

CLS

7.2

36R(650)

5980C01G01

6DSL-E2500

5980C01G01

—

DSL

0.6

2500

5980C01G02

6DSL-E3000

5980C01G02

—

DSL

0.6

3000

5980C01G03

6DSL-E4000

5980C01G03

—

DSL

0.6

4000

5980C01G04

6DSL-F5000

5980C01G04

—

DSL

0.6

5000

5980C03G05

7CLS70-44R

5980C03G05

—

CLS

7.2

44R(700)

5980C15G01

8DBA1-.5E

5980C15G01

—

DBA1

8.3

0.5

5980C15G03

8DBA1-5E

5980C15G03

—

DBA1

8.3

5E

5980C15G04

8DBA1-7E

5980C15G04

—

DBA1

8.3

7E

5980C15G05

8DBA1-10E

5980C15G05

—

DBA1

8.3

10E

5980C15G06

8DBA1-15E

5980C15G06

—

DBA1

8.3

15E

5980C15G07

8DBA1-20E

5980C15G07

—

DBA1

8.3

20E

5980C15G08

8DBA1-25E

5980C15G08

—

DBA1

8.3

25E

5980C15G09

8DBA1-30E

5980C15G09

—

DBA1

8.3

30E

5980C15G10

8DBA1-40E

5980C15G10

—

DBA1

8.3

40E

5980C15G11

8DBA1-50E

5980C15G11

—

DBA1

8.3

50E

5980C15G12

8DBA1650E

5980C15G12

—

DBA1

8.3

65E

5980C15G13

8DBA1-80E

5980C15G13

—

DBA1

8.3

80E

5980C15G14

8DBA1-100E

5980C15G14

—

DBA1

8.3

100E

5980C15G15

8DBA1-125E

5980C15G15

—

DBA1

8.3

125E

5980C15G16

8DBA1-150E

5980C15G16

—

DBA1

8.3

150E

5980C15G17

8DBA1-200E

5980C15G17

—

DBA1

8.3

200E

5980C15G21

15DBA1-.5E

5980C15G21

—

DBA1

15.5

0.5

5980C15G23

15DBA1-5E

5980C15G23

—

DBA1

15.5

5E

5980C15G24

15DBA1-7E

5980C15G24

—

DBA1

15.5

7E

5980C15G25

15DBA1-10E

5980C15G25

—

DBA1

15.5

10E

5980C15G26

15DBA1-15E

5980C15G26

—

DBA1

15.5

15E

5980C15G27

15DBA1-20E

5980C15G27

—

DBA1

15.5

20E

5980C15G28

15DBA1-25E

5980C15G28

—

DBA1

15.5

25E

5980C15G29

15DBA1-30E

5980C15G29

—

DBA1

15.5

30E

5980C15G30

15DBA1-40E

5980C15G30

—

DBA1

15.5

40E

5980C15G31

15DBA1-50E

5980C15G31

—

DBA1

15.5

50E

5980C15G32

15DBA1650E

5980C15G32

—

DBA1

15.5

65E

5980C15G33

15DBA1-80E

5980C15G33

—

DBA1

15.5

80E

5980C15G34

15DBA1-100E

5980C15G34

—

DBA1

15.5

100E

5980C15G35

15DBA1-125E

5980C15G35

—

DBA1

15.5

125E

5980C15G36

15DBA1-150E

5980C15G36

—

DBA1

15.5

150E

5980C15G37

15DBA1-200E

5980C15G37

—

DBA1

15.5

200E

V14-A2-72

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current
Rating
Amperes

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5980C16G01

25DBA1-.5E

5980C16G01

5980C16G03

25DBA1-5E

5980C16G03

—

DBA1

25.5

0.5

—

DBA1

25.5

5980C16G04

25DBA1-7E

5E

5980C16G04

—

DBA1

25.5

5980C16G05

7E

25DBA1-10E

5980C16G05

—

DBA1

25.5

10E

5980C16G06

25DBA1-15E

5980C16G06

—

DBA1

25.5

15E

5980C16G07

25DBA1-20E

5980C16G07

—

DBA1

25.5

20E

5980C16G08

25DBA1-25E

5980C16G08

—

DBA1

25.5

25E

5980C16G09

25DBA1-30E

5980C16G09

—

DBA1

25.5

30E

5980C16G10

25DBA1-40E

5980C16G10

—

DBA1

25.5

40E

5980C16G11

25DBA1-50E

5980C16G11

—

DBA1

25.5

50E

5980C16G12

25DBA1650E

5980C16G12

—

DBA1

25.5

65E

5980C16G13

25DBA1-80E

5980C16G13

—

DBA1

25.5

80E

5980C16G14

25DBA1-100E

5980C16G14

—

DBA1

25.5

100E

5980C16G15

25DBA1-125E

5980C16G15

—

DBA1

25.5

125E

5980C16G16

25DBA1-150E

5980C16G16

—

DBA1

25.5

150E

5980C16G17

25DBA1-200E

5980C16G17

—

DBA1

25.5

200E

5980C16G21

38DBA1-.5E

5980C16G21

—

DBA1

38

0.5

5980C16G23

38DBA1-5E

5980C16G23

—

DBA1

38

5E

5980C16G24

38DBA1-7E

5980C16G24

—

DBA1

38

7E

5980C16G25

38DBA1-10E

5980C16G25

—

DBA1

38

10E

5980C16G26

38DBA1-15E

5980C16G26

—

DBA1

38

15E

5980C16G27

38DBA1-20E

5980C16G27

—

DBA1

38

20E

5980C16G28

38DBA1-25E

5980C16G28

—

DBA1

38

25E

5980C16G29

38DBA1-30E

5980C16G29

—

DBA1

38

30E

5980C16G30

38DBA1-40E

5980C16G30

—

DBA1

38

40E

5980C16G31

38DBA1-50E

5980C16G31

—

DBA1

38

50E

5980C16G32

38DBA1650E

5980C16G32

—

DBA1

38

65E

5980C16G33

38DBA1-80E

5980C16G33

—

DBA1

38

80E

5980C16G34

38DBA1-100E

5980C16G34

—

DBA1

38

100E

5980C16G35

38DBA1-125E

5980C16G35

—

DBA1

38

125E

5980C16G36

38DBA1-150E

5980C16G36

—

DBA1

38

150E

5980C16G37

38DBA1-200E

5980C16G37

—

DBA1

38

200E

5980C17G01

48DBA1-.5E

5980C17G01

—

DBA1

48

0.5

5980C17G03

48DBA1-5E

5980C17G03

—

DBA1

48

5E

5980C17G04

48DBA1-7E

5980C17G04

—

DBA1

48

7E

5980C17G05

48DBA1-10E

5980C17G05

—

DBA1

48

10E

5980C17G06

48DBA1-15E

5980C17G06

—

DBA1

48

15E

5980C17G07

48DBA1-20E

5980C17G07

—

DBA1

48

20E

5980C17G08

48DBA1-25E

5980C17G08

—

DBA1

48

25E

5980C17G09

48DBA1-30E

5980C17G09

—

DBA1

48

30E

5980C17G10

48DBA1-40E

5980C17G10

—

DBA1

48

40E

5980C17G11

48DBA1-50E

5980C17G11

—

DBA1

48

50E

5980C17G12

48DBA1650E

5980C17G12

—

DBA1

48

65E

5980C17G13

48DBA1-80E

5980C17G13

—

DBA1

48

80E

5980C17G14

48DBA1-100E

5980C17G14

—

DBA1

48

100E

5980C17G15

48DBA1-125E

5980C17G15

—

DBA1

48

125E

5980C17G16

48DBA1-150E

5980C17G16

—

DBA1

48

150E

5980C17G17

48DBA1-200E

5980C17G17

—

DBA1

48

200E

5980C17G21

72DBA1-.5E

5980C17G21

—

DBA1

72

0.5

5980C17G23

72DBA1-5E

5980C17G23

—

DBA1

72

5E

5980C17G24

72DBA1-7E

5980C17G24

—

DBA1

72

7E

5980C17G25

72DBA1-10E

5980C17G25

—

DBA1

72

10E

5980C17G26

72DBA1-15E

5980C17G26

—

DBA1

72

15E

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-73

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5980C17G27

72DBA1-20E

5980C17G27

5980C17G28

72DBA1-25E

5980C17G28

—

DBA1

72

20E

—

DBA1

72

5980C17G29

72DBA1-30E

25E

5980C17G29

—

DBA1

72

5980C17G30

30E

72DBA1-40E

5980C17G30

—

DBA1

72

40E

5980C17G31

72DBA1-50E

5980C17G31

—

DBA1

72

50E

5980C17G32

72DBA1650E

5980C17G32

—

DBA1

72

65E

5980C17G33

72DBA1-80E

5980C17G33

—

DBA1

72

80E

5980C17G34

72DBA1-100E

5980C17G34

—

DBA1

72

100E

5980C17G35

72DBA1-125E

5980C17G35

—

DBA1

72

125E

5980C17G36

72DBA1-150E

5980C17G36

—

DBA1

72

150E

5980C17G37

72DBA1-200E

5980C17G37

—

DBA1

72

200E

5980C19G01

15CX-18C

5980C19G01

—

CX

15.5

18C

5980C19G02

15CX-20C

5980C19G02

—

CX

15.5

20C

5980C19G03

15CX-25C

5980C19G03

—

CX

15.5

25C

5980C19G04

15CX-30C

5980C19G04

—

CX

15.5

30C

5980C19G05

15CX-40C

5980C19G05

—

CX

15.5

40C

5980C19G06

15CX-6C

5980C19G06

—

CX

15.5

6C

5980C19G07

15CX-8C

5980C19G07

—

CX

15.5

8C

5980C19G08

15CX-12C

5980C19G08

—

CX

15.5

12C

5980C19G21

15CXI-18C

5980C19G21

—

CX

15.5

18C

5980C19G22

15CXI-20C

5980C19G22

—

CX

15.5

20C

5980C19G23

15CXI-25C

5980C19G23

—

CX

15.5

25C

5980C19G24

15CXI-30C

5980C19G24

—

CX

15.5

30C

5980C19G25

15CXI-40C

5980C19G25

—

CX

15.5

40C

5980C19G26

15CXI-6C

5980C19G26

—

CX

15.5

6C

5980C19G27

15CXI-8C

5980C19G27

—

CX

15.5

8C

5980C19G28

15CXI-12C

5980C19G28

—

CX

15.5

12C

5980C20G01

5NCLPT-.25E

5980C20G01

—

CLPT

5.5

0.25

5980C20G02

5NCLPT-.5E

5980C20G02

—

CLPT

5.5

0.5

5980C20G03

5NCLPT-2E

5980C20G03

—

CLPT

5.5

2E

5980C20G04

5NCLPT-4E

5980C20G04

—

CLPT

5.5

4E

5980C20G05

8NCLPT-2E

5980C20G05

—

CLPT

8.3

2E

5980C20G06

8NCLPT-4E

5980C20G06

—

CLPT

8.3

4E

5980C21G01

8HLE-20E

5981C30G03

—

HLE

8.3

20E

5980C21G02

8HLE-25E

5981C30G04

—

HLE

8.3

25E

5980C21G03

8HLE-30E

5981C30G05

—

HLE

8.3

30E

5980C21G04

8HLE-40E

5981C16G04

—

HLE

8.3

40E

5980C21G05

8HLE-50E

5981C16G05

—

HLE

8.3

50E

5980C21G06

8HLE-65E

5981C16G06

—

HLE

8.3

65E

5980C21G07

8HLE-80E

5981C16G07

—

HLE

8.3

80E

5980C21G08

8HLE-100E

5981C16G08

—

HLE

8.3

100E

5980C21G09

8HLE-125E

5981C16G09

—

HLE

8.3

125E

5980C21G10

8HLE-150E

5981C16G10

—

HLE

8.3

150E

5980C21G11

8HLE-175E

5981C16G11

—

HLE

8.3

175E

5980C22G01

15HLE-15E

5981C32G02

—

HLE

15.5

15E

5980C22G02

15HLE-20E

5981C32G03

—

HLE

15.5

20E

5980C22G03

15HLE-25E

5981C32G04

—

HLE

15.5

25E

5980C22G04

15HLE-30E

5981C32G05

—

HLE

15.5

30E

5980C22G05

15HLE-40E

5981C18G05

—

HLE

15.5

40E

5980C22G06

15HLE-50E

5981C18G06

—

HLE

15.5

50E

5980C22G07

15HLE-65E

5981C18G07

—

HLE

15.5

65E

5980C22G08

15HLE-80E

5981C18G08

—

HLE

15.5

80E

5980C22G09

15HLE-100E

5981C18G09

—

HLE

15.5

100E

V14-A2-74

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5980C22G10
5980C22G11

15HLE-125E

5981C18G10

15HLE-80E

5981C18G08

—

HLE

15.5

125E

—

HLE

15.5

5980C22G12

15HLE-100E

80E

5981C18G09

—

HLE

15.5

5980C22G13

100E

15HLE-125E

5981C18G10

—

HLE

15.5

125E

5980C23G01

15CLE-30E

5981C33G03

—

CLE

15.5

30E

5980C23G02

15CLE-40E

5981C19G04

—

CLE

15.5

40E

5980C23G03

15CLE-50E

5981C19G05

—

CLE

15.5

50E

5980C23G04

15CLE-65E

5981C19G06

—

CLE

15.5

65E

5980C23G05

15CLE-80E

5981C19G07

—

CLE

15.5

80E

5980C23G06

15CLE-100E

5981C19G08

—

CLE

15.5

100E

5980C23G07

15CLE-125E

5981C19G09

—

CLE

15.5

125E

5980C23G08

15CLE-150E

5981C19G10

—

CLE

15.5

150E

5980C24G01

8CLE-30E

5981C31G05

—

CLE

8.3

30E

5980C24G02

8CLE-40E

5981C17G04

—

CLE

8.3

40E

5980C24G03

8CLE-50E

5981C17G05

—

CLE

8.3

50E

5980C24G04

8CLE-65E

5981C17G06

—

CLE

8.3

65E

5980C24G05

8CLE-80E

5981C17G07

—

CLE

8.3

80E

5980C24G06

8CLE-100E

5981C17G08

—

CLE

8.3

100E

5980C24G07

8CLE-125E

5981C17G09

—

CLE

8.3

125E

5980C24G08

8CLE-150E

5981C17G10

—

CLE

8.3

150E

5980C24G09

8CLE-175E

5981C17G11

—

CLE

8.3

175E

5980C25G01

5HLE-30E

5981C28G05

—

HLE

5.5

30E

5980C25G02

5HLE-40E

5981C64G01

—

HLE

5.5

40E

5980C25G03

5HLE-50E

5981C64G02

—

HLE

5.5

50E

5980C25G04

5HLE-65E

5981C64G03

—

HLE

5.5

65E

5980C25G05

5HLE-80E

5981C64G04

—

HLE

5.5

80E

5980C25G06

5HLE-100E

5981C64G05

—

HLE

5.5

100E

5980C25G07

5HLE-125E

5981C64G06

—

HLE

5.5

125E

5980C25G08

5HLE-150E

5981C64G07

—

HLE

5.5

150E

5980C25G09

5HLE-175E

5981C64G08

—

HLE

5.5

175E

5980C25G10

5HLE-200E

5981C64G09

—

HLE

5.5

200E

5980C25G11

5HLE-250E

5981C64G10

—

HLE

5.5

250E

5980C26G01

5CLE-30E

5981C28G05

—

CLE

5.5

30E

5980C26G02

5CLE-40E

5981C64G01

—

CLE

5.5

40E

5980C26G03

5CLE-50E

5981C64G02

—

CLE

5.5

50E

5980C26G04

5CLE-65E

5981C64G03

—

CLE

5.5

65E

5980C26G05

5CLE-80E

5981C64G04

—

CLE

5.5

80E

5980C26G06

5CLE-100E

5981C64G05

—

CLE

5.5

100E

5980C26G07

5CLE-125E

5981C64G06

—

CLE

5.5

125E

5980C26G08

5CLE-150E

5981C64G07

—

CLE

5.5

150E

5980C26G09

5CLE-175E

5981C64G08

—

CLE

5.5

175E

5980C26G10

5CLE-200E

5981C64G09

—

CLE

5.5

200E

5980C26G11

5CLE-250E

5981C64G10

—

CLE

5.5

250E

5980C29G01

Obsolete—contact Eaton

—

RBA2-IND

—

—

—

5980C29G02

Obsolete—contact Eaton

—

RBA4-IND

—

—

—

5980C31G01

8HLE-200E

5981C22G01

—

HLE

8.3

200E

5980C31G02

8HLE-250E

5981C22G02

—

HLE

8.3

250E

5980C31G03

8HLE-300E

5981C22G03

—

HLE

8.3

300E

5980C31G04

8HLE-350E

5981C22G04

—

HLE

8.3

350E

5980C32G01

15HLE-150E

5981C24G01

—

HLE

15.5

150E

5980C32G02

15HLE-175E

5981C24G02

—

HLE

15.5

175E

5980C32G03

15HLE-200E

5981C24G03

—

HLE

15.5

200E

5980C32G04

15HLE-250E

5981C24G04

—

HLE

15.5

250E

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-75

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5980C32G05

15HLE-150E

5981C24G01

5980C32G06

15HLE-175E

5981C24G02

—

HLE

15.5

175E

—

HLE

15.5

5980C32G07

15HLE-200E

200E

5981C24G03

—

HLE

15.5

5980C32G08

250E

15HLE-250E

5981C24G04

—

HLE

15.5

250E

5980C33G01

15CLE-175E

5981C25G01

—

CLE

15.5

175E

5980C33G02

15CLE-200E

5981C25G02

—

CLE

15.5

200E

5980C33G03

15CLE-250E

5981C25G03

—

CLE

15.5

250E

5980C33G04

15CLE-300E

5981C25G04

—

CLE

15.5

300E

5980C34G01

8CLE-200E

5981C23G01

—

CLE

8.3

200E

5980C34G02

8CLE-250E

5981C23G02

—

CLE

8.3

250E

5980C34G03

8CLE-300E

5981C23G03

—

CLE

8.3

300E

5980C34G04

8CLE-350E

5981C23G04

—

CLE

8.3

350E

5980C35G01

5HLE-300E

5981C66G01

—

HLE

5.5

300E

5980C35G02

5HLE-350E

5981C66G02

—

HLE

5.5

350E

5980C35G03

5HLE-400E

5981C66G03

—

HLE

5.5

400E

5980C35G04

5HLE-450E

5981C66G04

—

HLE

5.5

450E

5980C36G01

5CLE-300E

5981C67G01

—

CLE

5.5

300E

5980C36G02

5CLE-350E

5981C67G02

—

CLE

5.5

350E

5980C36G03

5CLE-400E

5981C67G03

—

CLE

5.5

400E

5980C36G04

5CLE-450E

5981C67G04

—

CLE

5.5

450E

5980C38G01

8RBA2-IDH

5981C50G01

—

RBA2

8.3

200

5980C38G02

15RBA2-IDH

5981C50G02

—

RBA2

15.5

200

5980C38G03

25RBA2-IDH

5981C50G03

—

RBA2

25.5

200

5980C38G04

38RBA2-IDH

5981C50G04

—

RBA2

38

200

5980C39G01

8RBA4-IDH

5981C52G01

—

RBA4

8.3

400

5980C39G02

15RBA4-IDH

5981C52G02

—

RBA4

15.5

400

5980C39G03

25RBA4-IDH

5981C52G03

—

RBA4

25.5

300

5980C39G04

38RBA4-IDH

5981C52G04

—

RBA4

38

300

5980C61G01

5AHLE-30E

5981C46G05

—

HLE

5.5

30E

5980C61G02

5AHLE-40E

5981C46G06

—

HLE

5.5

40E

5980C61G03

5AHLE-50E

5981C46G07

—

HLE

5.5

50E

5980C61G04

5AHLE-65E

5981C46G08

—

HLE

5.5

65E

5980C61G05

5AHLE-80E

5981C46G09

—

HLE

5.5

80E

5980C61G06

5AHLE-100E

5981C46G10

—

HLE

5.5

100E

5980C61G07

5AHLE-125E

5981C46G11

—

HLE

5.5

125E

5980C61G08

5AHLE-150E

5981C46G12

—

HLE

5.5

150E

5980C61G09

5AHLE-175E

5981C46G13

—

HLE

5.5

175E

5980C61G10

5AHLE-200E

5981C46G14

—

HLE

5.5

200E

5980C61G11

5AHLE-250E

5981C46G15

—

HLE

5.5

250E

5980C62G01

8AHLE-20E

5981C47G03

—

HLE

8.3

20E

5980C62G02

8AHLE-25E

5981C47G04

—

HLE

8.3

25E

5980C62G03

8AHLE-30E

5981C47G05

—

HLE

8.3

30E

5980C62G04

8AHLE-40E

5981C47G06

—

HLE

8.3

40E

5980C62G05

8AHLE-50E

5981C47G07

—

HLE

8.3

50E

5980C62G06

8AHLE-65E

5981C47G08

—

HLE

8.3

65E

5980C62G07

8AHLE-80E

5981C47G09

—

HLE

8.3

80E

5980C62G08

8AHLE-100E

5981C47G10

—

HLE

8.3

100E

5980C62G09

8AHLE-125E

5981C47G11

—

HLE

8.3

125E

5980C62G10

8AHLE-150E

5981C47G12

—

HLE

8.3

150E

5980C62G11

8AHLE-175E

5981C47G13

—

HLE

8.3

175E

5980C63G01

Obsolete—contact Eaton

—

15AHLE-15E

—

—

—

5980C63G02

Obsolete—contact Eaton

—

15AHLE-20E

—

—

—

5980C63G03

Obsolete—contact Eaton

—

15AHLE-25E

—

—

—

V14-A2-76

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5980C63G04

Obsolete—contact Eaton

—

5980C63G05

Obsolete—contact Eaton

—

15AHLE-30E

—

—

—

15AHLE-40E

—

—

5980C63G06

Obsolete—contact Eaton

—

—

15AHLE-50E

—

—

5980C63G07

—

Obsolete—contact Eaton

—

15AHLE-65E

—

—

—

5980C63G08

Obsolete—contact Eaton

—

15AHLE-80E

—

—

—

5980C63G09

Obsolete—contact Eaton

—

15AHLE-100E

—

—

—

5980C63G10

Obsolete—contact Eaton

—

15AHLE-125E

—

—

—

5980C64G01

5AHLE-300E

5981C46G16

—

HLE

5.5

300E

5980C64G02

5AHLE-300E

5981C46G17

—

HLE

5.5

350E

5980C64G03

5AHLE-300E

5981C46G18

—

HLE

5.5

400E

5980C64G04

5AHLE-300E

5981C46G19

—

HLE

5.5

450E

5980C65G01

8AHLE-200E

5981C47G14

—

HLE

8.3

200E

5980C65G02

8AHLE-250E

5981C47G15

—

HLE

8.3

250E

5980C65G03

8AHLE-300E

5981C47G16

—

HLE

8.3

300E

5980C65G04

8AHLE-350E

5981C47G17

—

HLE

8.3

350E

5980C66G01

Obsolete—contact Eaton

—

15AHLE-150E

—

—

—

5980C66G02

Obsolete—contact Eaton

—

15AHLE-175E

—

—

—

5980C66G03

Obsolete—contact Eaton

—

15AHLE-200E

—

—

—

5980C66G04

Obsolete—contact Eaton

—

15AHLE-250E

—

—

—

5980C74G01

8RBA8-INH

5981C54G01

—

RBA8

8.3

720

5980C74G02

15RBA8-INH

5981C54G02

—

RBA9

15.5

720

5980C74G03

25RBA8-INH

5981C54G03

—

RBA10

25.5

540

5980C74G04

38RBA8-INH

5981C54G04

—

RBA11

38

540

5980C81G01

5CLS70-9R

5980C81G01

—

CLS

5.08

9R(200)

5980C81G02

5CLS70-6R

5980C81G02

—

CLS

5.08

6R(170)

5980C81G03

5CLS70-5R

5980C81G03

—

CLS

5.08

5R(150)

5980C81G04

5CLS70-4R

5980C81G04

—

CLS

5.08

4R(130)

5980C81G05

5CLS70-3R

5980C81G05

—

CLS

5.08

3R(100)

5980C81G06

5CLS70-2R

5980C81G06

—

CLS

5.08

2R(70)

5980C81G07

5CLE8-80E

5980C81G07

—

HLE

5.5

80E

5980C81G08

5CLE8-100E

5980C81G08

—

HLE

5.5

100E

5980C81G09

5CLE8-125E

5980C81G09

—

HLE

5.5

125E

5980C81G10

5CLE8-150E

5980C81G10

—

HLE

5.5

150E

5980C81G11

5CLE8-200E

5980C81G11

—

HLE

5.5

200E

5980C81G12

5CLE8-250E

5980C81G12

—

HLE

5.5

250E

5980C81G13

5CLE8-65E

5980C81G13

—

HLE

5.5

65E

5980C81G14

5CLE8-30E

5980C81G14

—

HLE

5.5

30E

5980C81G15

5CLE8-50E

5980C81G15

—

HLE

5.5

50E

5980C81G16

5CLE8-450E

5980C81G16

—

HLE

5.5

40E

5980C82G01

8HLE-20E

5981C30G03

—

HLE

8.3

20E

5980C82G02

8HLE-25E

5981C30G04

—

HLE

8.3

25E

5980C82G03

8HLE-30E

5981C30G05

—

HLE

8.3

30E

5980C82G04

8HLE-40E

5981C16G04

—

HLE

8.3

40E

5980C82G05

8HLE-50E

5981C16G05

—

HLE

8.3

50E

5980C82G06

8HLE-65E

5981C16G06

—

HLE

8.3

65E

5980C82G07

8HLE-80E

5981C16G07

—

HLE

8.3

80E

5980C82G08

8HLE-100E

5981C16G08

—

HLE

8.3

100E

5980C82G09

8HLE-125E

5981C16G09

—

HLE

8.3

125E

5980C82G10

8HLE-150E

5981C16G10

—

HLE

8.3

150E

5980C82G11

8HLE-175E

5981C16G11

—

HLE

8.3

175E

5980C83G01

15HLE-15E

5981C32G02

—

HLE

15.5

15E

5980C83G02

15HLE-20E

5981C32G03

—

HLE

15.5

20E

5980C83G03

15HLE-25E

5981C32G04

—

HLE

15.5

25E

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-77

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5980C83G04

15HLE-30E

5981C32G05

5980C83G05

15HLE-40E

5981C18G05

—

HLE

15.5

30E

—

HLE

15.5

5980C83G06

15HLE-50E

40E

5981C18G06

—

HLE

15.5

5980C83G07

50E

15HLE-65E

5981C18G07

—

HLE

15.5

65E

5980C83G08

15HLE-80E

5981C18G08

—

HLE

15.5

80E

5980C83G09

15HLE-100E

5981C18G09

—

HLE

15.5

100E

5980C83G10

15HLE-125E

5981C18G10

—

HLE

15.5

125E

5980C84G01

15CLE-20E

5981C33G03

—

CLE

15.5

20E

5980C84G02

15CLE-25E

5981C33G04

—

CLE

15.5

25E

5980C84G03

15CLE-30E

5981C33G05

—

CLE

15.5

30E

5980C84G04

15CLE-40E

5981C19G04

—

CLE

15.5

40E

5980C84G05

15CLE-50E

5981C19G05

—

CLE

15.5

50E

5980C84G06

15CLE-65E

5981C19G06

—

CLE

15.5

65E

5980C84G07

15CLE-80E

5981C19G07

—

CLE

15.5

80E

5980C84G08

15CLE-100E

5981C19G08

—

CLE

15.5

100E

5980C84G09

15CLE-125E

5981C19G09

—

CLE

15.5

125E

5980C84G10

15CLE-150E

5981C19G10

—

CLE

15.5

150E

5980C85G01

8CLE-20E

5981C31G03

—

CLE

8.3

20E

5980C85G02

8CLE-25E

5981C31G04

—

CLE

8.3

25E

5980C85G03

8CLE-30E

5981C31G05

—

CLE

8.3

30E

5980C85G04

8CLE-40E

5981C17G04

—

CLE

8.3

40E

5980C85G05

8CLE-50E

5981C17G05

—

CLE

8.3

50E

5980C85G06

8CLE-65E

5981C17G06

—

CLE

8.3

65E

5980C85G07

8CLE-80E

5981C17G07

—

CLE

8.3

80E

5980C85G08

8CLE-100E

5981C17G08

—

CLE

8.3

100E

5980C85G09

8CLE-125E

5981C17G09

—

CLE

8.3

125E

5980C85G10

8CLE-150E

5981C17G10

—

CLE

8.3

150E

5980C85G11

8CLE-175E

5981C17G11

—

CLE

8.3

175E

5980C86G01

8HLE-200E

5981C22G01

—

HLE

8.3

200E

5980C86G02

8HLE-250E

5981C22G02

—

HLE

8.3

250E

5980C86G03

8HLE-300E

5981C22G03

—

HLE

8.3

300E

5980C86G04

8HLE-350E

5981C22G04

—

HLE

8.3

350E

5980C87G01

15HLE-150E

5981C24G01

—

HLE

15.5

150E

5980C87G02

15HLE-175E

5981C24G02

—

HLE

15.5

175E

5980C87G03

15HLE-200E

5981C24G03

—

HLE

15.5

200E

5980C87G04

15HLE-250E

5981C24G04

—

HLE

15.5

250E

5980C88G01

15CLE-175E

5981C25G01

—

CLE

15.5

175E

5980C88G02

15CLE-200E

5981C25G02

—

CLE

15.5

200E

5980C88G03

15CLE3505E

5981C25G03

—

CLE

15.5

250E

5980C88G04

15CLE-300E

5981C25G04

—

CLE

15.5

300E

5980C89G01

8CLE-200E

5981C23G01

—

CLE

8.3

200E

5980C89G02

8CLE-250E

5981C23G02

—

CLE

8.3

250E

5980C89G03

8CLE-300E

5981C23G03

—

CLE

8.3

300E

5980C89G04

8CLE-350E

5981C23G04

—

CLE

8.3

350E

5980C96G01

5HLE-10E

5981C28G01

—

HLE

5.5

10E

5980C96G02

5HLE-15E

5981C28G02

—

HLE

5.5

15E

5980C96G03

5HLE-20E

5981C28G03

—

HLE

5.5

20E

5980C96G04

5HLE-25E

5981C28G04

—

HLE

5.5

25E

5980C96G05

5HLE-30E

5981C28G05

—

HLE

5.5

30E

5980C97G01

5CLE-10E-D

5981C29G01

—

CLE

5.5

10E

5980C97G02

5CLE-15E-D

5981C29G02

—

CLE

5.5

15E

5980C97G03

5CLE-20E-D

5981C29G03

—

CLE

5.5

20E

5980C97G04

5CLE-25E-D

5981C29G04

—

CLE

5.5

25E

V14-A2-78

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

5980C97G05

5CLE-30E

5981C29G05

—

CLE

5.5

30E

5980C98G01

8HLE-10E

5981C30G01

—

HLE

8.3

10E

5980C98G02

8HLE-15E

5981C30G02

—

HLE

8.3

15E

5980C98G03

8HLE-20E

5981C30G03

—

HLE

8.3

20E

5980C98G04

8HLE-25E

5981C30G04

—

HLE

8.3

25E

5980C98G05

8HLE-30E

5981C30G05

—

HLE

8.3

30E

5980C99G01

8CLE-10E-D

5981C31G01

—

CLE

8.3

10E

5980C99G02

8CLE-15E-D

5981C31G02

—

CLE

8.3

15E

5980C99G03

8CLE-20E-D

5981C31G03

—

CLE

8.3

20E

5980C99G04

8CLE-25E-D

5981C31G04

—

CLE

8.3

25E

5980C99G05

8CLE-30E

5981C31G05

—

CLE

8.3

30E

5981C01G01

15HLE-10E

5981C32G01

—

HLE

15.5

10E

5981C01G02

15HLE-15E

5981C32G02

—

HLE

15.5

15E

5981C01G03

15HLE-20E

5981C32G03

—

HLE

15.5

20E

5981C01G04

15HLE-25E

5981C32G04

—

HLE

15.5

25E

5981C01G05

15HLE-30E

5981C32G05

—

HLE

15.5

30E

5981C02G01

15CLE-10E-D

5981C33G01

—

CLE

15.5

10E

5981C02G02

15CLE-15E-D

5981C33G02

—

CLE

15.5

15E

5981C02G03

15CLE-20E-D

5981C33G03

—

CLE

15.5

20E

5981C02G04

15CLE-25E-D

5981C33G04

—

CLE

15.5

25E

5981C02G05

15CLE-30E

5981C33G05

—

CLE

15.5

30E

5981C03G01

5HLE-PDM-D

5981C03G01

—

HLE

5.5

250

5981C03G02

8HLE-PDM-D

5981C03G02

—

HLE

8.3

175

5981C03G03

15HLE-PDM-D

5981C03G03

—

HLE

15.5

125

5981C03G04

5HLE-GDM-D

5981C03G04

—

HLE

5.5

250

5981C03G05

8HLE-GDM-D

5981C03G05

—

HLE

8.3

175

5981C03G06

15HLE-GDM-D

5981C03G06

—

HLE

15.5

125

5981C03G07

5HLE-PNM-D

5981C03G07

—

HLE

5.5

250

5981C03G08

8HLE-PNM-D

5981C03G08

—

HLE

8.3

175

5981C03G09

15HLE-PNM-D

5981C03G09

—

HLE

15.5

125

5981C03G10

5HLE-GNM-D

5981C03G10

—

HLE

5.5

25

5981C03G11

8HLE-GNM-D

5981C03G11

—

HLE

8.3

175

5981C03G12

15HLE-GNM-D

5981C03G12

—

HLE

15.5

125

5981C03G13

5HLE-PDM-E

5981C03G13

—

HLE

5.5

450

5981C03G14

8HLE-PDM-E

5981C03G14

—

HLE

8.3

350

5981C03G15

15HLE-PDM-E

5981C03G15

—

HLE

15.5

250

5981C03G16

5HLE-GDM-E

5981C03G16

—

HLE

5.5

450

5981C03G17

8HLE-GDM-E

5981C03G17

—

HLE

8.3

350

5981C03G18

15HLE-GDM-E

5981C03G18

—

HLE

15.5

250

5981C03G19

5HLE-PNM-E

5981C03G19

—

HLE

5.5

450

5981C03G20

8HLE-PNM-E

5981C03G20

—

HLE

8.3

350

5981C03G21

15HLE-PNM-E

5981C03G21

—

HLE

15.5

250

5981C03G22

5HLE-GNM-E

5981C03G22

—

HLE

5.5

450

5981C03G23

8HLE-GNM-E

5981C03G23

—

HLE

8.3

350

5981C03G24

15HLE-GNM-E

5981C03G24

—

HLE

15.5

250

5981G05G01

5NCLPT-10E

5981G05G01

—

CLPT

5.5

10E

5981G05G02

5NCLPT-5E

5981G05G02

—

CLPT

5.5

5E

5981G05G03

5NCLPT-3E

5981G05G03

—

CLPT

5.5

3E

5981G05G04

5NCLPT-2E

5981G05G04

—

CLPT

5.5

2E

5981G05G05

5NCLPT-1E

5981G05G05

—

CLPT

5.5

1E

5981G05G06

5NCLPT-0.5E

5981G05G06

—

CLPT

5.5

0.5E

5981C06G01

8NCLPT-10E

5981C06G01

—

CLPT

8.3

10E

5981C06G02

8NCLPT-5E

5981C06G02

—

CLPT

8.3

5E

Description

Type

Voltage
Rating
kV Max.

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current
Rating
Amperes

V14-A2-79

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5981C06G03

8NCLPT-3E

5981C06G03

5981C06G04

8NCLPT-2E

5981C06G04

—

CLPT

8.3

3E

—

CLPT

8.3

5981C06G05

8NCLPT-1E

2E

5981C06G05

—

CLPT

8.3

5981C06G06

1E

8NCLPT-0.5E

5981C06G06

—

CLPT

8.3

0.5E

5981C07G01

15NCLPT-10E

5981C07G01

—

CLPT

15.5

10E

5981C07G02

15NCLPT-5E

5981C07G02

—

CLPT

15.5

5E

5981C07G03

15NCLPT-3E

5981C07G03

—

CLPT

15.5

3E

5981C07G04

15NCLPT-2E

5981C07G04

—

CLPT

15.5

2E

5981C07G05

15NCLPT-1E

5981C07G05

—

CLPT

15.5

1E

5981C07G06

15NCLPT-0.5E

5981C07G06

—

CLPT

15.5

0.5E

5981C14G01

5HLE-30E

5981C28G05

—

HLE

5.5

30E

5981C14G02

5HLE-40E

5981C64G01

—

HLE

5.5

40E

5981C14G03

5HLE-50E

5981C64G02

—

HLE

5.5

50E

5981C14G04

5HLE-65E

5981C64G03

—

HLE

5.5

65E

5981C14G05

5HLE-80E

5981C64G04

—

HLE

5.5

80E

5981C14G06

5HLE-100E

5981C64G05

—

HLE

5.5

100E

5981C14G07

5HLE-125E

5981C64G06

—

HLE

5.5

125E

5981C14G08

5HLE-150E

5981C64G07

—

HLE

5.5

150E

5981C14G09

5HLE-175E

5981C64G08

—

HLE

5.5

175E

5981C14G10

5HLE-200E

5981C64G09

—

HLE

5.5

200E

5981C14G11

5HLE-250E

5981C64G10

—

HLE

5.5

250E

5981C15G01

5CLE-30E

5981C29G05

—

CLE

5.5

30E

5981C15G02

5CLE-40E

5981C65G01

—

CLE

5.5

40E

5981C15G03

5CLE-50E

5981C65G02

—

CLE

5.5

50E

5981C15G04

5CLE-65E

5981C65G03

—

CLE

5.5

65E

5981C15G05

5CLE-80E

5981C65G04

—

CLE

5.5

80E

5981C15G06

5CLE-100E

5981C65G05

—

CLE

5.5

100E

5981C15G07

5CLE-125E

5981C65G06

—

CLE

5.5

125E

5981C15G08

5CLE-150E

5981C65G07

—

CLE

5.5

150E

5981C15G09

5CLE-175E

5981C65G08

—

CLE

5.5

175E

5981C15G10

5CLE-200E

5981C65G09

—

CLE

5.5

200E

5981C15G11

5CLE-250E

5981C65G10

—

CLE

5.5

250E

5981C16G04

8HLE-40E

5981C16G04

—

HLE

8.3

40E

5981C16G05

8HLE-50E

5981C16G05

—

HLE

8.3

50E

5981C16G06

8HLE-65E

5981C16G06

—

HLE

8.3

65E

5981C16G07

8HLE-80E

5981C16G07

—

HLE

8.3

80E

5981C16G08

8HLE-100E

5981C16G08

—

HLE

8.3

100E

5981C16G09

8HLE-125E

5981C16G09

—

HLE

8.3

125E

5981C16G10

8HLE-150E

5981C16G10

—

HLE

8.3

150E

5981C16G11

8HLE-175E

5981C16G11

—

HLE

8.3

175E

5981C17G04

8CLE-40E

5981C17G04

—

CLE

8.3

40E

5981C17G05

8CLE-50E

5981C17G05

—

CLE

8.3

50E

5981C17G06

8CLE-65E

5981C17G06

—

CLE

8.3

65E

5981C17G07

8CLE-80E

5981C17G07

—

CLE

8.3

80E

5981C17G08

8CLE-100E

5981C17G08

—

CLE

8.3

100E

5981C17G09

8CLE-125E

5981C17G09

—

CLE

8.3

125E

5981C17G10

8CLE-150E

5981C17G10

—

CLE

8.3

150E

5981C17G11

8CLE-175E

5981C17G11

—

CLE

8.3

175E

5981C18G05

15HLE-40E

5981C18G05

—

HLE

15.5

40E

5981C18G06

15HLE-50E

5981C18G06

—

HLE

15.5

50E

5981C18G07

15HLE-65E

5981C18G07

—

HLE

15.5

65E

5981C18G08

15HLE-80E

5981C18G08

—

HLE

15.5

80E

5981C18G09

15HLE-100E

5981C18G09

—

HLE

15.5

100E

V14-A2-80

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5981C18G10

15HLE-125E

5981C18G10

5981C19G04

15CLE-40E

5981C19G04

—

HLE

15.5

125E

—

CLE

15.5

5981C19G05

15CLE-50E

40E

5981C19G05

—

CLE

15.5

5981C19G06

50E

15CLE-65E

5981C19G06

—

CLE

15.5

65E

5981C19G07

15CLE-80E

5981C19G07

—

CLE

15.5

80E

5981C19G08

15CLE-100E

5981C19G08

—

CLE

15.5

100E

5981C19G09

15CLE-125E

5981C19G09

—

CLE

15.5

125E

5981C19G10

15CLE-150E

5981C19G10

—

CLE

15.5

150E

5981C20G01

5HLE-300E

5981C66G01

—

HLE

5.5

300E

5981C20G02

5HLE-350E

5981C66G02

—

HLE

5.5

350E

5981C20G03

5HLE-400E

5981C66G03

—

HLE

5.5

400E

5981C20G04

5HLE-450E

5981C66G04

—

HLE

5.5

450E

5981C21G01

5CLE-300E

5981C67G01

—

CLE

5.5

300E

5981C21G02

5CLE-350E

5981C67G02

—

CLE

5.5

350E

5981C21G03

5CLE-400E

5981C67G03

—

CLE

5.5

400E

5981C21G04

5CLE-450E

5981C67G04

—

CLE

5.5

450E

5981C22G01

8CLE-200E

5981C22G01

—

CLE

8.3

200E

5981C22G02

8CLE-250E

5981C22G02

—

CLE

8.3

250E

5981C22G03

8CLE-300E

5981C22G03

—

CLE

8.3

300E

5981C22G04

8CLE-350E

5981C22G04

—

CLE

8.3

350E

5981C23G01

8HLE-200E

5981C23G01

—

HLE

8.3

200E

5981C23G02

8HLE-250E

5981C23G02

—

HLE

8.3

250E

5981C23G03

8HLE-300E

5981C23G03

—

HLE

8.3

300E

5981C23G04

8HLE-350E

5981C23G04

—

HLE

8.3

350E

5981C24G01

15CLE-175E

5981C24G01

—

CLE

15.5

175E

5981C24G02

15CLE-200E

5981C24G02

—

CLE

15.5

200E

5981C24G03

15CLE-250E

5981C24G03

—

CLE

15.5

250E

5981C24G04

15CLE-300E

5981C24G04

—

CLE

15.5

300E

5981C25G01

15HLE-150E

5981C25G01

—

HLE

15.5

150E

5981C25G02

15HLE-175E

5981C25G02

—

HLE

15.5

175E

5981C25G03

15HLE-200E

5981C25G03

—

HLE

15.5

200E

5981C25G04

15HLE-250E

5981C25G04

—

HLE

15.5

250E

5981C27G01

2ACLS-4L

5981C27G01

Conducting link

CLS

2.54

450

5981C27G02

8ACLS-4L

5981C27G02

Conducting link

CLS

8.3

480

5981C27G03

2BCLS-4L

5981C27G03

Conducting link

CLS

2.54

450

5981C27G04

8BCLS-4L

5981C27G04

Conducting link

CLS

8.3

480

5981C27G05

8HLE-CL

5981C27G05

Conducting link

HLE

8.3

350

5981C27G06

8CLE-CL

5981C27G06

Conducting link

CLE

8.3

350

5981C27G07

15HLE-CL

5981C27G07

Conducting link

HLE

15.5

250

5981C27G08

15CLE-CL

5981C27G08

Conducting link

CLE

15.5

300

5981C28G01

5HLE-10E

5981C28G01

—

HLE

5.5

10E

5981C28G02

5HLE-15E

5981C28G02

—

HLE

5.5

15E

5981C28G03

5HLE-20E

5981C28G03

—

HLE

5.5

20E

5981C28G04

5HLE-25E

5981C28G04

—

HLE

5.5

25E

5981C28G05

5HLE-30E

5981C28G05

—

HLE

5.5

30E

5981C29G01

5CLE-10E-D

5981C29G01

—

CLE

5.5

10E

5981C29G02

5CLE-15E-D

5981C29G02

—

CLE

5.5

15E

5981C29G03

5CLE-20E-D

5981C29G03

—

CLE

5.5

20E

5981C29G04

5CLE-25E-D

5981C29G04

—

CLE

5.5

25E

5981C29G05

5CLE-30E

5981C29G05

—

CLE

5.5

30E

5981C30G01

8HLE-10E

5981C30G01

—

HLE

8.3

10E

5981C30G02

8HLE-15E

5981C30G02

—

HLE

8.3

15E

5981C30G03

8HLE-20E

5981C30G03

—

HLE

8.3

20E

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-81

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5981C30G04

8HLE-25E

5981C30G04

5981C30G05

8HLE-30E

5981C30G05

—

HLE

8.3

25E

—

HLE

8.3

5981C31G01

8CLE-10E-D

30E

5981C31G01

—

CLE

8.3

5981C31G02

10E

8CLE-15E-D

5981C31G02

—

CLE

8.3

15E

5981C31G03

8CLE-20E-D

5981C31G03

—

CLE

8.3

20E

5981C31G04

8CLE-25E-D

5981C31G04

—

CLE

8.3

25E

5981C31G05

8CLE-30E

5981C31G05

—

CLE

8.3

30E

5981C32G01

15HLE-10E

5981C32G01

—

HLE

15.5

10E

5981C32G02

15HLE-15E

5981C32G02

—

HLE

15.5

15E

5981C32G03

15HLE-20E

5981C32G03

—

HLE

15.5

20E

5981C32G04

15HLE-25E

5981C32G04

—

HLE

15.5

25E

5981C32G05

15HLE-30E

5981C32G05

—

HLE

15.5

30E

5981C33G01

15CLE-10E-D

5981C33G01

—

CLE

15.5

10E

5981C33G02

15CLE-15E-D

5981C33G02

—

CLE

15.5

15E

5981C33G03

15CLE-20E-D

5981C33G03

—

CLE

15.5

20E

5981C33G04

15CLE-25E-D

5981C33G04

—

CLE

15.5

25E

5981C33G05

15CLE-30E

5981C33G05

—

CLE

15.5

30E

5981C40G01

8AHLE-20E

5981C47G03

—

HLE

8.3

20E

5981C40G02

8AHLE-25E

5981C47G04

—

HLE

8.3

25E

5981C40G03

8AHLE-30E

5981C47G05

—

HLE

8.3

30E

5981C40G04

8AHLE-40E

5981C47G06

—

HLE

8.3

40E

5981C40G05

8AHLE-50E

5981C47G07

—

HLE

8.3

50E

5981C40G06

8AHLE-65E

5981C47G08

—

HLE

8.3

65E

5981C40G07

8AHLE-80E

5981C47G09

—

HLE

8.3

80E

5981C40G08

8AHLE-100E

5981C47G10

—

HLE

8.3

100E

5981C40G09

8AHLE-125E

5981C47G11

—

HLE

8.3

125E

5981C40G10

8AHLE-150E

5981C47G12

—

HLE

8.3

150E

5981C40G11

8AHLE-175E

5981C47G13

—

HLE

8.3

175E

5981C41G01

8AHLE-200E

5981C47G14

—

HLE

8.3

200E

5981C41G02

8AHLE-250E

5981C47G15

—

HLE

8.3

250E

5981C41G03

8AHLE-300E

5981C47G16

—

HLE

8.3

300E

5981C41G04

8AHLE-350E

5981C47G17

—

HLE

8.3

350E

5981C46G01

5AHLE-10E

5981C46G01

—

HLE

5.5

10E

5981C46G02

5AHLE-15E

5981C46G02

—

HLE

5.5

15E

5981C46G03

5AHLE-20E

5981C46G03

—

HLE

5.5

20E

5981C46G04

5AHLE-25E

5981C46G04

—

HLE

5.5

25E

5981C46G05

5AHLE-30E

5981C46G05

—

HLE

5.5

30E

5981C46G06

5AHLE-40E

5981C46G06

—

HLE

5.5

40E

5981C46G07

5AHLE-50E

5981C46G07

—

HLE

5.5

50E

5981C46G08

5AHLE-65E

5981C46G08

—

HLE

5.5

65E

5981C46G09

5AHLE-80E

5981C46G09

—

HLE

5.5

80E

5981C46G10

5AHLE-100E

5981C46G10

—

HLE

5.5

100E

5981C46G11

5AHLE-125E

5981C46G11

—

HLE

5.5

125E

5981C46G12

5AHLE-150E

5981C46G12

—

HLE

5.5

150E

5981C46G13

5AHLE-175E

5981C46G13

—

HLE

5.5

175E

5981C46G14

5AHLE-200E

5981C46G14

—

HLE

5.5

200E

5981C46G15

5AHLE-250E

5981C46G15

—

HLE

5.5

250E

5981C46G16

5AHLE-300E

5981C46G16

—

HLE

5.5

300E

5981C46G17

5AHLE-350E

5981C46G17

—

HLE

5.5

350E

5981C46G18

5AHLE-400E

5981C46G18

—

HLE

5.5

400E

5981C46G19

5AHLE-450E

5981C46G19

—

HLE

5.5

450E

5981C47G01

8AHLE-10E

5981C47G01

—

HLE

8.3

10E

5981C47G02

8AHLE-15E

5981C47G02

—

HLE

8.3

15E

V14-A2-82

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5981C47G03

8AHLE-20E

5981C47G03

5981C47G04

8AHLE-25E

5981C47G04

—

HLE

8.3

20E

—

HLE

8.3

5981C47G05

8AHLE-30E

25E

5981C47G05

—

HLE

8.3

5981C47G06

30E

8AHLE-40E

5981C47G06

—

HLE

8.3

40E

5981C47G07

8AHLE-50E

5981C47G07

—

HLE

8.3

50E

5981C47G08

8AHLE-65E

5981C47G08

—

HLE

8.3

65E

5981C47G09

8AHLE-80E

5981C47G09

—

HLE

8.3

80E

5981C47G10

8AHLE-100E

5981C47G10

—

HLE

8.3

100E

5981C47G11

8AHLE-125E

5981C47G11

—

HLE

8.3

125E

5981C47G12

8AHLE-150E

5981C47G12

—

HLE

8.3

150E

5981C47G13

8AHLE-175E

5981C47G13

—

HLE

8.3

175E

5981C47G14

8AHLE-200E

5981C47G14

—

HLE

8.3

200E

5981C47G15

8AHLE-250E

5981C47G15

—

HLE

8.3

250E

5981C47G16

8AHLE-300E

5981C47G16

—

HLE

8.3

300E

5981C47G17

8AHLE-350E

5981C47G17

—

HLE

8.3

350E

5981C48G01

5AHLE-10E

5981C46G01

—

HLE

5.5

10E

5981C48G02

5AHLE-15E

5981C46G02

—

HLE

5.5

15E

5981C48G03

5AHLE-20E

5981C46G03

—

HLE

5.5

20E

5981C48G04

5AHLE-25E

5981C46G04

—

HLE

5.5

25E

5981C48G05

5AHLE-30E

5981C46G05

—

HLE

5.5

30E

5981C49G01

8AHLE-10E

5981C47G01

—

HLE

8.3

10E

5981C49G02

8AHLE-15E

5981C47G02

—

HLE

8.3

15E

5981C49G03

8AHLE-20E

5981C47G03

—

HLE

8.3

20E

5981C49G04

8AHLE-25E

5981C47G04

—

HLE

8.3

25E

5981C49G05

8AHLE-30E

5981C47G05

—

HLE

8.3

30E

5981C50G01

8RBA2-IDH

5981C50G01

—

RBA2

8.3

200

5981C50G02

15RBA2-IDH

5981C50G02

—

RBA2

15.5

200

5981C50G03

25RBA2-IDH

5981C50G03

—

RBA2

25.5

200

5981C50G04

38RBA2-IDH

5981C50G04

—

RBA2

38

200

5981C50G05

8RBA2-ILBDH

5981C50G05

—

RBA2

8.3

200

5981C50G06

15RBA2-ILBDH

5981C50G06

—

RBA2

15.5

200

5981C50G07

25RBA2-ILBDH

5981C50G07

—

RBA2

25.5

200

5981C51G01

8RBA2-INH

5981C51G01

—

RBA2

8.3

200

5981C51G02

15RBA2-INH

5981C51G02

—

RBA2

15.5

200

5981C51G03

25RA2-INH

5981C51G03

—

RBA2

25.5

200

5981C51G04

38RBA2-INH

5981C51G04

—

RBA2

38

200

5981C52G01

8RBA4-IDH

5981C52G01

—

RBA4

8.3

400

5981C52G02

15RBA4-IDH

5981C52G02

—

RBA4

15.5

400

5981C52G03

25RBA4-IDH

5981C52G03

—

RBA4

25.5

300

5981C52G04

38RBA4-IDH

5981C52G04

—

RBA4

38

300

5981C52G05

8RBA4-ILBDH

5981C52G05

—

RBA4

8.3

400

5981C52G06

15RBA4-ILBDH

5981C52G06

—

RBA4

15.5

400

5981C52G07

25RBA4-ILBDH

5981C52G07

—

RBA4

25.5

300

5981C53G01

8RBA4-INH

5981C53G01

—

RBA4

8.3

400

5981C53G02

15RBA4-INH

5981C53G02

—

RBA4

15.5

400

5981C53G03

25RBA4-INH

5981C53G03

—

RBA4

25.5

300

5981C53G04

38RBA4-INH

5981C53G04

—

RBA4

38

300

5981C54G01

8RBA8-INH

5981C54G01

—

RBA4

8.3

720

5981C54G02

15RBA8-INH

5981C54G02

—

RBA4

15.5

720

5981C54G03

25RBA8-INH

5981C54G03

—

RBA4

25.5

540

5981C54G04

38RBA8-INH

5981C54G04

—

RBA4

38

540

5981C58G01

5BHCL-750E

5981C58G01

—

HCL

5.5

750E

5981C58G02

5BHCL-900E

5981C58G02

—

HCL

5.5

900E

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-83

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5981C61G01

15HCL-250E

5981C61G01

5981C61G02

15HCL-300E

5981C61G02

—

HCL

15.5

250E

—

HCL

15.5

5981C61G03

15HCL-200E

300E

5981C61G03

—

HCL

15.5

5981C61G04

200E

15HCL-150E

5981C61G04

—

HCL

15.5

150E

5981C61G05

15HCL-175E

5981C61G05

—

HCL

15.5

175E

5981C61G06

15BHCL-300E

5981C61G06

—

HCL

15.5

300E

5981C62G01

5HCL-500E

5981C62G01

—

HCL

5.5

500E

5981C62G02

5HCL-600E

5981C62G02

—

HCL

5.5

600E

5981C62G03

5HCL-450E

5981C62G03

—

HCL

5.5

450E

5981C62G04

5HCL-400E

5981C62G04

—

HCL

5.5

400E

5981C62G05

5HCL-300E

5981C62G05

—

HCL

5.5

300E

5981C62G06

5HCL-250E

5981C62G06

—

HCL

5.5

250E

5981C62G07

5HCL-200E

5981C62G07

—

HCL

5.5

200E

5981C62G08

5BHCL-600E

5981C62G08

—

HCL

5.5

600E

5981C62G09

5BHCL-500E

5981C62G09

—

HCL

5.5

500E

5981C62G10

5BHCL-450E

5981C62G10

—

HCL

5.5

450E

5981C62G11

5BHCL-400E

5981C62G11

—

HCL

5.5

400E

5981C62G12

5BHCL-300E

5981C62G12

—

HCL

5.5

300E

5981C62G13

5BHCL-250E

5981C62G13

—

HCL

5.5

250E

5981C62G14

5BHCL-200E

5981C62G14

—

HCL

5.5

200E

5981C64G01

5HLE-40E

5981C64G01

—

HLE

5.5

40E

5981C64G02

5HLE-50E

5981C64G02

—

HLE

5.5

50E

5981C64G03

5HLE-65E

5981C64G03

—

HLE

5.5

65E

5981C64G04

5HLE-80E

5981C64G04

—

HLE

5.5

80E

5981C64G05

5HLE-100E

5981C64G05

—

HLE

5.5

100E

5981C64G06

5HLE-125E

5981C64G06

—

HLE

5.5

125E

5981C64G07

5HLE-150E

5981C64G07

—

HLE

5.5

150E

5981C64G08

5HLE-175E

5981C64G08

—

HLE

5.5

175E

5981C64G09

5HLE-200E

5981C64G09

—

HLE

5.5

200E

5981C64G10

5HLE-250E

5981C64G10

—

HLE

5.5

250E

5981C65G1

5CLE-40E

5981C65G01

—

CLE

5.5

40E

5981C65G2

5CLE-50E

5981C65G02

—

CLE

5.5

50E

5981C65G3

5CLE-65E

5981C65G03

—

CLE

5.5

65E

5981C65G4

5CLE-80E

5981C65G04

—

CLE

5.5

80E

5981C65G5

5CLE-100E

5981C65G05

—

CLE

5.5

100E

5981C65G6

5CLE-125E

5981C65G06

—

CLE

5.5

125E

5981C65G7

5CLE-150E

5981C65G07

—

CLE

5.5

150E

5981C65G8

5CLE-175E

5981C65G08

—

CLE

5.5

175E

5981C65G9

5CLE-200E

5981C65G09

—

CLE

5.5

200E

5981C65G10

5CLE-250E

5981C65G10

—

CLE

5.5

250E

5981C66G01

5HLE-300E

5981C66G01

—

HLE

5.5

300E

5981C66G02

5HLE-350E

5981C66G02

—

HLE

5.5

350E

5981C66G03

5HLE-400E

5981C66G03

—

HLE

5.5

400E

5981C66G04

5HLE-450E

5981C66G04

—

HLE

5.5

450E

5981C67G01

5CLE-300E

5981C67G01

—

CLE

5.5

300E

5981C67G02

5CLE-350E

5981C67G02

—

CLE

5.5

350E

5981C67G03

5CLE-400E

5981C67G03

—

CLE

5.5

400E

5981C67G04

5CLE-450E

5981C67G04

—

CLE

5.5

450E

5981C68G01

15HCL-125E

5981C68G01

—

HCL

15.5

125E

5981C68G02

15HCL-100E

5981C68G02

—

HCL

15.5

100E

5981C68G03

15HCL-80E

5981C68G03

—

HCL

15.5

80E

5981C68G04

15HCL-65E

5981C68G04

—

HCL

15.5

65E

5981C69G02

DBU-MFLR

5981C69G02

—

DBU

—

200

V14-A2-84

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5981C75G01

17DBU-3K

5981C75G01

5981C75G02

17DBU-6K

5981C75G02

—

DBU

17

3K

—

DBU

17

5981C75G03

17DBU-8K

6K

5981C75G03

—

DBU

17

5981C75G04

8K

17DBU-10K

5981C75G04

—

DBU

17

10K

5981C75G05

17DBU-12K

5981C75G05

—

DBU

17

12K

5981C75G06

17DBU-15K

5981C75G06

—

DBU

17

15K

5981C75G07

17DBU-20K

5981C75G07

—

DBU

17

20K

5981C75G08

17DBU-25K

5981C75G08

—

DBU

17

25K

5981C75G09

17DBU-30K

5981C75G09

—

DBU

17

30K

5981C75G10

17DBU-40K

5981C75G10

—

DBU

17

40K

5981C75G11

17DBU-50K

5981C75G11

—

DBU

17

50K

5981C75G12

17DBU-65K

5981C75G12

—

DBU

17

65K

5981C75G13

17DBU-80K

5981C75G13

—

DBU

17

80K

5981C75G14

17DBU-100K

5981C75G14

—

DBU

17

100K

5981C75G15

17DBU-140K

5981C75G15

—

DBU

17

140K

5981C75G16

17DBU-200K

5981C75G16

—

DBU

17

200K

5981C76G01

17DBU-5E

5981C76G01

—

DBU

17

5E

5981C76G02

17DBU-7E

5981C76G02

—

DBU

17

7E

5981C76G03

17DBU-10E

5981C76G03

—

DBU

17

10E

5981C76G04

17DBU-12E

5981C76G04

—

DBU

17

12E

5981C76G05

17DBU-15E

5981C76G05

—

DBU

17

15E

5981C76G06

17DBU-20E

5981C76G06

—

DBU

17

20E

5981C76G07

17DBU25E

5981C76G07

—

DBU

17

25E

5981C76G08

17DBU-30E

5981C76G08

—

DBU

17

30E

5981C76G09

17DBU-40E

5981C76G09

—

DBU

17

40E

5981C76G10

17DBU-50E

5981C76G10

—

DBU

17

50E

5981C76G11

17DBU-65E

5981C76G11

—

DBU

17

65E

5981C76G12

17DBU-80E

5981C76G12

—

DBU

17

80E

5981C76G13

17DBU-100E

5981C76G13

—

DBU

17

100E

5981C76G14

17DBU-125E

5981C76G14

—

DBU

17

125E

5981C76G15

17DBU-150E

5981C76G15

—

DBU

17

150E

5981C76G16

17DBU-175E

5981C76G16

—

DBU

17

175E

5981C76G17

17DBU-200E

5981C76G17

—

DBU

17

200E

5981C77G01

17DBU-15SE

5981C77G01

—

DBU

17

15SE

5981C77G02

17DBU-20SE

5981C77G02

—

DBU

17

20SE

5981C77G03

17DBU25SE

5981C77G03

—

DBU

17

25SE

5981C77G04

17DBU-30SE

5981C77G04

—

DBU

17

30SE

5981C77G05

17DBU-40SE

5981C77G05

—

DBU

17

40SE

5981C77G06

17DBU-50SE

5981C77G06

—

DBU

17

50SE

5981C77G07

17DBU-65SE

5981C77G07

—

DBU

17

65SE

5981C77G08

17DBU-80SE

5981C77G08

—

DBU

17

80SE

5981C77G09

17DBU-100SE

5981C77G09

—

DBU

17

100SE

5981C77G10

17DBU-125SE

5981C77G10

—

DBU

17

125SE

5981C77G11

17DBU-150SE

5981C77G11

—

DBU

17

150SE

5981C77G12

17DBU-175SE

5981C77G12

—

DBU

17

175SE

5981C77G13

17DBU-200SE

5981C77G13

—

DBU

17

200SE

5981C85G01

27DBU-3K

5981C85G01

—

DBU

27

3K

5981C85G02

27DBU-6K

5981C85G02

—

DBU

27

6K

5981C85G03

27DBU-8K

5981C85G03

—

DBU

27

8K

5981C85G04

27DBU-10K

5981C85G04

—

DBU

27

10K

5981C85G05

27DBU-12K

5981C85G05

—

DBU

27

12K

5981C85G06

27DBU-15K

5981C85G06

—

DBU

27

15K

5981C85G07

27DBU-20K

5981C85G07

—

DBU

27

20K

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-85

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5981C85G08

27DBU-25K

5981C85G08

5981C85G09

27DBU-30K

5981C85G09

—

DBU

27

25K

—

DBU

27

5981C85G10

27DBU-40K

30K

5981C85G10

—

DBU

27

5981C85G11

40K

27DBU-50K

5981C85G11

—

DBU

27

50K

5981C85G12

27DBU-65K

5981C85G12

—

DBU

27

65K

5981C85G13

27DBU-80K

5981C85G13

—

DBU

27

80K

5981C85G14

27DBU-100K

5981C85G14

—

DBU

27

100K

5981C85G15

27DBU-140K

5981C85G15

—

DBU

27

140K

5981C85G16

27DBU-200K

5981C85G16

—

DBU

27

200K

5981C86G01

27DBU-5E

5981C86G01

—

DBU

27

5E

5981C86G02

27DBU-7E

5981C86G02

—

DBU

27

7E

5981C86G03

27DBU-10E

5981C86G03

—

DBU

27

10E

5981C86G04

27DBU-12E

5981C86G04

—

DBU

27

12E

5981C86G05

27DBU-15E

5981C86G05

—

DBU

27

15E

5981C86G06

27DBU-20E

5981C86G06

—

DBU

27

20E

5981C86G07

27DBU25E

5981C86G07

—

DBU

27

25E

5981C86G08

27DBU-30E

5981C86G08

—

DBU

27

30E

5981C86G09

27DBU-40E

5981C86G09

—

DBU

27

40E

5981C86G10

27DBU-50E

5981C86G10

—

DBU

27

50E

5981C86G11

27DBU-65E

5981C86G11

—

DBU

27

65E

5981C86G12

27DBU-80E

5981C86G12

—

DBU

27

80E

5981C86G13

27DBU-100E

5981C86G13

—

DBU

27

100E

5981C86G14

27DBU-125E

5981C86G14

—

DBU

27

125E

5981C86G15

27DBU-150E

5981C86G15

—

DBU

27

150E

5981C86G16

27DBU-175E

5981C86G16

—

DBU

27

175E

5981C86G17

27DBU-200E

5981C86G17

—

DBU

27

200E

5981C87G01

27DBU-15SE

5981C87G01

—

DBU

27

15SE

5981C87G02

27DBU-20SE

5981C87G02

—

DBU

27

20SE

5981C87G03

27DBU25SE

5981C87G03

—

DBU

27

25SE

5981C87G04

27DBU-30SE

5981C87G04

—

DBU

27

30SE

5981C87G05

27DBU-40SE

5981C87G05

—

DBU

27

40SE

5981C87G06

27DBU-50SE

5981C87G06

—

DBU

27

50SE

5981C87G07

27DBU-65SE

5981C87G07

—

DBU

27

65SE

5981C87G08

27DBU-80SE

5981C87G08

—

DBU

27

80SE

5981C87G09

27DBU-100SE

5981C87G09

—

DBU

27

100SE

5981C87G10

27DBU-125SE

5981C87G10

—

DBU

27

125SE

5981C87G11

27DBU-150SE

5981C87G11

—

DBU

27

150SE

5981C87G12

27DBU-175SE

5981C87G12

—

DBU

27

175SE

5981C87G13

27DBU-200SE

5981C87G13

—

DBU

27

200SE

5981C95G01

38DBU-3K

5981C95G01

—

DBU

38

3K

5981C95G02

38DBU-6K

5981C95G02

—

DBU

38

6K

5981C95G03

38DBU-8K

5981C95G03

—

DBU

38

8K

5981C95G04

38DBU-10K

5981C95G04

—

DBU

38

10K

5981C95G05

38DBU-12K

5981C95G05

—

DBU

38

12K

5981C95G06

38DBU-15K

5981C95G06

—

DBU

38

15K

5981C95G07

38DBU-20K

5981C95G07

—

DBU

38

20K

5981C95G08

38DBU-25K

5981C95G08

—

DBU

38

25K

5981C95G09

38DBU-30K

5981C95G09

—

DBU

38

30K

5981C95G10

38DBU-40K

5981C95G10

—

DBU

38

40K

5981C95G11

38DBU-50K

5981C95G11

—

DBU

38

50K

5981C95G12

38DBU-65K

5981C95G12

—

DBU

38

65K

5981C95G13

38DBU-80K

5981C95G13

—

DBU

38

80K

5981C95G14

38DBU-100K

5981C95G14

—

DBU

38

100K

V14-A2-86

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5981C95G15

38DBU-140K

5981C95G15

5981C95G16

38DBU-200K

5981C95G16

—

DBU

38

140K

—

DBU

38

5981C96G01

38DBU-5E

200K

5981C96G01

—

DBU

38

5981C96G02

5E

38DBU-7E

5981C96G02

—

DBU

38

7E

5981C96G03

38DBU-10E

5981C96G03

—

DBU

38

10E

5981C96G04

38DBU-12E

5981C96G04

—

DBU

38

12E

5981C96G05

38DBU-15E

5981C96G05

—

DBU

38

15E

5981C96G06

38DBU-20E

5981C96G06

—

DBU

38

20E

5981C96G07

38DBU25E

5981C96G07

—

DBU

38

25E

5981C96G08

38DBU-30E

5981C96G08

—

DBU

38

30E

5981C96G09

38DBU-40E

5981C96G09

—

DBU

38

40E

5981C96G10

38DBU-50E

5981C96G10

—

DBU

38

50E

5981C96G11

38DBU-65E

5981C96G11

—

DBU

38

65E

5981C96G12

38DBU-80E

5981C96G12

—

DBU

38

80E

5981C96G13

38DBU-100E

5981C96G13

—

DBU

38

100E

5981C96G14

38DBU-125E

5981C96G14

—

DBU

38

125E

5981C96G15

38DBU-150E

5981C96G15

—

DBU

38

150E

5981C96G16

38DBU-175E

5981C96G16

—

DBU

38

175E

5981C96G17

38DBU-200E

5981C96G17

—

DBU

38

200E

5981C97G01

38DBU-15SE

5981C97G01

—

DBU

38

15SE

5981C97G02

38DBU-20SE

5981C97G02

—

DBU

38

20SE

5981C97G03

38DBU25SE

5981C97G03

—

DBU

38

25SE

5981C97G04

38DBU-30SE

5981C97G04

—

DBU

38

30SE

5981C97G05

38DBU-40SE

5981C97G05

—

DBU

38

40SE

5981C97G06

38DBU-50SE

5981C97G06

—

DBU

38

50SE

5981C97G07

38DBU-65SE

5981C97G07

—

DBU

38

65SE

5981C97G08

38DBU-80SE

5981C97G08

—

DBU

38

80SE

5981C97G09

38DBU-100SE

5981C97G09

—

DBU

38

100SE

5981C97G10

38DBU-125SE

5981C97G10

—

DBU

38

125SE

5981C97G11

38DBU-150SE

5981C97G11

—

DBU

38

150SE

5981C97G12

38DBU-175SE

5981C97G12

—

DBU

38

175SE

5981C97G13

38DBU-200SE

5981C97G13

—

DBU

38

200SE

5982C01G01

8CLS-2R

5982C01G01

—

CLS

8.3

2R(70)

5982C02G02

8CLS-3R

5982C02G02

—

CLS

8.3

3R(100)

5982C02G03

8CLS-4R

5982C02G03

—

CLS

8.3

4R(130)

5982C02G04

8CLS-5R

5982C02G04

—

CLS

8.3

5R(150)

5982C02G05

8CLS-6R

5982C02G05

—

CLS

8.3

6R(170)

5982C02G06

7CLS-9R

5982C02G06

—

CLS

7.2

9R(200)

5982C02G07

7CLS-12R

5982C02G07

—

CLS

7.2

12R(230)

5982C02G10

7CLS-18R

5982C02G10

—

CLS

7.2

18R(390)

5982C02G11

7CLS-24R

5982C02G11

—

CLS

7.2

24R(450)

5982C19G04

HCL-NL

5982C19G04

—

HCL

—

600

5982C29G01

HCL-NL

5982C19G04

—

HCL

—

600

5982C29G04

HCL-NL

5982C19G04

—

HCL

—

600

5982C31G01

5BCLS-30

5982C31G01

—

CLS

5.5

30

5982C31G02

5BCLS-2R

5982C31G02

—

CLS

5.5

2R(70)

5982C31G03

5BCLS-3R

5982C31G03

—

CLS

5.5

3R(100)

5982C31G04

5BCLS-4R

5982C31G04

—

CLS

5.5

4R(130)

5982C31G05

5BCLS-5R

5982C31G05

—

CLS

5.5

5R(150)

5982C31G06

5BCLS-6R

5982C31G06

—

CLS

5.5

6R(170)

5982C31G07

5BCLS-9R

5982C31G07

—

CLS

5.5

9R(200)

5982C31G08

5BCLS-12R

5982C31G08

—

CLS

5.5

12R(230)

5982C32G01

5BCLS-18R

5982C32G01

—

CLS

5.5

18R(390)

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-87

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5982C32G02

5BCLS-24R

5982C32G02

5982C32G03

4BCLS-26R

5982C32G03

—

CLS

5.5

24R(450)

—

CLS

4.6

5982C34G01

15HCL-10E

26R(480)

5982C34G01

—

HCL

15.5

5982C34G02

10E

15HCL-15E

5982C34G02

—

HCL

15.5

15E

5982C34G03

15HCL-20E

5982C34G03

—

HCL

15.5

20E

5982C34G04

15HCL-25E

5982C34G04

—

HCL

15.5

25E

5982C34G05

15HCL-30E

5982C34G05

—

HCL

15.5

30E

5982C34G06

15HCL-40E

5982C34G06

—

HCL

15.5

40E

5982C34G07

15HCL-50E

5982C34G07

—

HCL

15.5

50E

5982C35G01

5HCL-10E

5982C35G01

—

HCL

5.5

10E

5982C35G02

5HCL-15E

5982C35G02

—

HCL

5.5

15E

5982C35G03

5HCL-20E

5982C35G03

—

HCL

5.5

20E

5982C35G04

5HCL-25E

5982C35G04

—

HCL

5.5

25E

5982C35G05

5HCL-30E

5982C35G05

—

HCL

5.5

30E

5982C35G06

5HCL-40E

5982C35G06

—

HCL

5.5

40E

5982C35G07

5HCL-50E

5982C35G07

—

HCL

5.5

50E

5982C35G08

5HCL-65E

5982C35G08

—

HCL

5.5

65E

5982C35G09

5HCL-80E

5982C35G09

—

HCL

5.5

80E

5982C35G10

5HCL-100E

5982C35G10

—

HCL

5.5

100E

5982C35G11

5HCL-125E

5982C35G11

—

HCL

5.5

125E

5982C35G12

5HCL-150E

5982C35G12

—

HCL

5.5

150E

5982C36G01

7BCLS-2R

5982C36G01

—

CLS

8.3

2R(70)

5982C36G02

7BCLS-3R

5982C36G02

—

CLS

8.3

3R(100)

5982C36G03

7BCLS-4R

5982C36G03

—

CLS

8.3

4R(130)

5982C36G04

7BCLS-5R

5982C36G04

—

CLS

8.3

5R(150)

5982C36G05

7BCLS-6R

5982C36G05

—

CLS

8.3

6R(170)

5982C36G06

7BCLS-9R

5982C36G06

—

CLS

7.2

9R(200)

5982C36G07

7BCLS-12R

5982C36G07

—

CLS

7.2

12R(230)

5982C36G08

7BCLS-18R

5982C36G08

—

CLS

7.2

18R(390)

5982C36G09

7BCLS-24R

5982C36G09

—

CLS

7.2

24R(450)

5982C44G01

8RBA4-.5E

5982C44G01

—

RBA4

8.3

0.5

5982C44G02

8RBA4-3E

5982C44G02

—

RBA4

8.3

3

5982C44G03

8RBA4-5E

5982C44G03

—

RBA4

8.3

5E

5982C44G04

8RBA4-7E

5982C44G04

—

RBA4

8.3

7E

5982C44G05

8RBA4-10E

5982C44G05

—

RBA4

8.3

10E

5982C44G06

8RBA4-15E

5982C44G06

—

RBA4

8.3

15E

5982C44G07

8RBA4-20E

5982C44G07

—

RBA4

8.3

20E

5982C44G08

8RBA4-25E

5982C44G08

—

RBA4

8.3

25E

5982C44G09

8RBA4-30E

5982C44G09

—

RBA4

8.3

30E

5982C44G10

8RBA4-40E

5982C44G10

—

RBA4

8.3

40E

5982C44G11

8RBA4-50E

5982C44G11

—

RBA4

8.3

50E

5982C44G12

8RBA4-65E

5982C44G12

—

RBA4

8.3

65E

5982C44G13

8RBA4-80E

5982C44G13

—

RBA4

8.3

80E

5982C44G14

8RBA4-100E

5982C44G14

—

RBA4

8.3

100E

5982C44G15

8RBA4-125E

5982C44G15

—

RBA4

8.3

125E

5982C44G16

8RBA4-150E

5982C44G16

—

RBA4

8.3

150E

5982C44G17

8RBA4-175E

5982C44G17

—

RBA4

8.3

175E

5982C44G18

8RBA4-200E

5982C44G18

—

RBA4

8.3

200E

5982C44G19

8RBA4-250E

5982C44G19

—

RBA4

8.3

250E

5982C44G20

8RBA4-300E

5982C44G20

—

RBA4

8.3

300E

5982C44G22

8RBA4-400E

5982C44G22

—

RBA4

8.3

400E

5982C44G26

15RBA4-.5E

5982C44G26

—

RBA4

15.5

0.5

5982C44G27

15RBA4-3E

5982C44G27

—

RBA4

15.5

3

V14-A2-88

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5982C44G28

15RBA4-5E

5982C44G28

5982C44G29

15RBA4-7E

5982C44G29

—

RBA4

15.5

5E

—

RBA4

15.5

5982C44G30

15RBA4-10E

7E

5982C44G30

—

RBA4

15.5

5982C44G31

10E

15RBA4-15E

5982C44G31

—

RBA4

15.5

15E

5982C44G32

15RBA4-20E

5982C44G32

—

RBA4

15.5

20E

5982C44G33

15RBA4-25E

5982C44G33

—

RBA4

15.5

25E

5982C44G34

15RBA4-30E

5982C44G34

—

RBA4

15.5

30E

5982C44G35

15RBA4-40E

5982C44G35

—

RBA4

15.5

40E

5982C44G36

15RBA4-50E

5982C44G36

—

RBA4

15.5

50E

5982C44G37

15RBA4-65E

5982C44G37

—

RBA4

15.5

65E

5982C44G38

15RBA4-80E

5982C44G38

—

RBA4

15.5

80E

5982C44G39

15RBA4-100E

5982C44G39

—

RBA4

15.5

100E

5982C44G40

15RBA4-125E

5982C44G40

—

RBA4

15.5

125E

5982C44G41

15RBA4-150E

5982C44G41

—

RBA4

15.5

150E

5982C44G42

15RBA4-175E

5982C44G42

—

RBA4

15.5

175E

5982C44G43

15RBA4-200E

5982C44G43

—

RBA4

15.5

200E

5982C44G44

15RBA4-250E

5982C44G44

—

RBA4

15.5

250E

5982C44G45

15RBA4-300E

5982C44G45

—

RBA4

15.5

300E

5982C44G47

15RBA4-400E

5982C44G47

—

RBA4

15.5

400E

5982C44G51

25RBA4-.5E

5982C44G51

—

RBA4

25.5

0.5

5982C44G52

25RBA4-3E

5982C44G52

—

RBA4

25.5

3

5982C44G53

25RBA4-5E

5982C44G53

—

RBA4

25.5

5E

5982C44G54

25RBA4-7E

5982C44G54

—

RBA4

25.5

7E

5982C44G55

25RBA4-10E

5982C44G55

—

RBA4

25.5

10E

5982C44G56

25RBA4-15E

5982C44G56

—

RBA4

25.5

15E

5982C44G57

25RBA4-20E

5982C44G57

—

RBA4

25.5

20E

5982C44G58

25RBA4-25E

5982C44G58

—

RBA4

25.5

25E

5982C44G59

25RBA4-30E

5982C44G59

—

RBA4

25.5

30E

5982C44G60

25RBA4-40E

5982C44G60

—

RBA4

25.5

40E

5982C44G61

25RBA4-50E

5982C44G61

—

RBA4

25.5

50E

5982C44G62

25RBA4-65E

5982C44G62

—

RBA4

25.5

65E

5982C44G63

25RBA4-80E

5982C44G63

—

RBA4

25.5

80E

5982C44G64

25RBA4-100E

5982C44G64

—

RBA4

25.5

100E

5982C44G65

25RBA4-125E

5982C44G65

—

RBA4

25.5

125E

5982C44G66

25RBA4-150E

5982C44G66

—

RBA4

25.5

150E

5982C44G67

25RBA4-175E

5982C44G67

—

RBA4

25.5

175E

5982C44G68

25RBA4-200E

5982C44G68

—

RBA4

25.5

200E

5982C44G69

25RBA4-250E

5982C44G69

—

RBA4

25.5

250E

5982C44G70

25RBA4-300E

5982C44G70

—

RBA4

25.5

300E

5982C44G76

38RBA4-.5E

5982C44G76

—

RBA4

38

0.5

5982C44G77

38RBA4-3E

5982C44G77

—

RBA4

38

3

5982C44G78

38RBA4-5E

5982C44G78

—

RBA4

38

5E

5982C44G79

38RBA4-7E

5982C44G79

—

RBA4

38

7E

5982C44G80

38RBA4-10E

5982C44G80

—

RBA4

38

10E

5982C44G81

38RBA4-15E

5982C44G81

—

RBA4

38

15E

5982C44G82

38RBA4-20E

5982C44G82

—

RBA4

38

20E

5982C44G83

38RBA4-25E

5982C44G83

—

RBA4

38

25E

5982C44G84

38RBA4-30E

5982C44G84

—

RBA4

38

30E

5982C44G85

38RBA4-40E

5982C44G85

—

RBA4

38

40E

5982C44G86

38RBA4-50E

5982C44G86

—

RBA4

38

50E

5982C44G87

38RBA4-65E

5982C44G87

—

RBA4

38

65E

5982C44G88

38RBA4-80E

5982C44G88

—

RBA4

38

80E

5982C44G89

38RBA4-100E

5982C44G89

—

RBA4

38

100E

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-89

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5982C44G90

38RBA4-125E

5982C44G90

5982C44G91

38RBA4-150E

5982C44G91

—

RBA4

38

125E

—

RBA4

38

5982C44G92

38RBA4-175E

150E

5982C44G92

—

RBA4

38

5982C44G93

175E

38RBA4-200E

5982C44G93

—

RBA4

38

200E

5982C44G94

38RBA4-250E

5982C44G94

—

RBA4

38

250E

5982C44G95

38RBA4-300E

5982C44G95

—

RBA4

38

300E

5982C47G01

2BCLS-25

5982C47G01

—

CLS

2.54

25

5982C47G02

2BCLS-2R

5982C47G02

—

CLS

2.54

2R(70)

5982C47G03

2BCLS-3R

5982C47G03

—

CLS

2.54

3R(100)

5982C47G04

2BCLS-4R

5982C47G04

—

CLS

2.54

4R(130)

5982C47G05

2BCLS-5R

5982C47G05

—

CLS

2.54

5R(150)

5982C47G06

2BCLS-6R

5982C47G06

—

CLS

2.54

6R(170)

5982C47G07

2BCLS-9R

5982C47G07

—

CLS

2.54

9R(200)

5982C47G08

2BCLS-12R

5982C47G08

—

CLS

2.54

12R(230)

5982C47G09

2BCLS-18R

5982C47G09

—

CLS

2.54

18R(390)

5982C47G10

2BCLS-24R

5982C47G10

—

CLS

2.54

24R(450)

5982C49A07

8RBT4-20E

5982C49A07

—

RBA4

8.3

20E

5982C49A08

8RBT4-25E

5982C49A08

—

RBA4

8.3

25E

5982C49A09

8RBT4-30E

5982C49A09

—

RBA4

8.3

30E

5982C49A10

8RBT4-40E

5982C49A10

—

RBA4

8.3

40E

5982C49A11

8RBT4-50E

5982C49A11

—

RBA4

8.3

50E

5982C49A12

8RBT4-65E

5982C49A12

—

RBA4

8.3

65E

5982C49A13

8RBT4-80E

5982C49A13

—

RBA4

8.3

80E

5982C49A14

8RBT4-100E

5982C49A14

—

RBA4

8.3

100E

5982C49A15

8RBT4-125E

5982C49A15

—

RBA4

8.3

125E

5982C49A16

8RBT4-150E

5982C49A16

—

RBA4

8.3

150E

5982C49A18

8RBT4-200E

5982C49A18

—

RBA4

8.3

200E

5982C49A19

8RBT4-250E

5982C49A19

—

RBA4

8.3

250E

5982C49A20

8RBT4-300E

5982C49A20

—

RBA4

8.3

300E

5982C49A21

8RBT4-400E

5982C49A21

—

RBA4

8.3

400E

5982C49A32

15RBT4-20E

5982C49A32

—

RBA4

15.5

20E

5982C49A33

15RBT4-25E

5982C49A33

—

RBA4

15.5

25E

5982C49A34

15RBT4-30E

5982C49A34

—

RBA4

15.5

30E

5982C49A35

15RBT4-40E

5982C49A35

—

RBA4

15.5

40E

5982C49A36

15RBT4-50E

5982C49A36

—

RBA4

15.5

50E

5982C49A37

15RBT4-65E

5982C49A37

—

RBA4

15.5

65E

5982C49A38

15RBT4-80E

5982C49A38

—

RBA4

15.5

80E

5982C49A39

15RBT4-100E

5982C49A39

—

RBA4

15.5

100E

5982C49A40

15RBT4-125E

5982C49A40

—

RBA4

15.5

125E

5982C49A41

15RBT4-150E

5982C49A41

—

RBA4

15.5

150E

5982C49A43

15RBT4-200E

5982C49A43

—

RBA4

15.5

200E

5982C49A44

15RBT4-250E

5982C49A44

—

RBA4

15.5

250E

5982C49A45

15RBT4-300E

5982C49A45

—

RBA4

15.5

300E

5982C49A46

15RBT4-400E

5982C49A46

—

RBA4

15.5

400E

5982C49A57

25RBT4-20E

5982C49A57

—

RBA4

25.5

20E

5982C49A58

25RBT4-25E

5982C49A58

—

RBA4

25.5

25E

5982C49A59

25RBT4-30E

5982C49A59

—

RBA4

25.5

30E

5982C49A60

25RBT4-40E

5982C49A60

—

RBA4

25.5

40E

5982C49A61

25RBT4-50E

5982C49A61

—

RBA4

25.5

50E

5982C49A62

25RBT4-65E

5982C49A62

—

RBA4

25.5

65E

5982C49A63

25RBT4-80E

5982C49A63

—

RBA4

25.5

80E

5982C49A64

25RBT4-100E

5982C49A64

—

RBA4

25.5

100E

5982C49A65

25RBT4-125E

5982C49A65

—

RBA4

25.5

125E

V14-A2-90

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5982C49A66

25RBT4-150E

5982C49A66

5982C49A68

25RBT4-200E

5982C49A68

—

RBA4

25.5

150E

—

RBA4

25.5

5982C49A69

25RBT4-250E

200E

5982C49A69

—

RBA4

25.5

5982C49A70

250E

25RBT4-300E

5982C49A70

—

RBA4

25.5

300E

5982C49A82

38RBT4-20E

5982C49A82

—

RBA4

38

20E

5982C49A83

38RBT4-25E

5982C49A83

—

RBA4

38

25E

5982C49A84

38RBT4-30E

5982C49A84

—

RBA4

38

30E

5982C49A85

38RBT4-40E

5982C49A85

—

RBA4

38

40E

5982C49A86

38RBT4-50E

5982C49A86

—

RBA4

38

50E

5982C49A87

38RBT4-65E

5982C49A87

—

RBA4

38

65E

5982C49A88

38RBT4-80E

5982C49A88

—

RBA4

38

80E

5982C49A89

38RBT4-100E

5982C49A89

—

RBA4

38

100E

5982C49A90

38RBT4-125E

5982C49A90

—

RBA4

38

125E

5982C49A91

38RBT4-150E

5982C49A91

—

RBA4

38

150E

5982C49A93

38RBT4-200E

5982C49A93

—

RBA4

38

200E

5982C49A94

38RBT4-250E

5982C49A94

—

RBA4

38

250E

5982C49A95

38RBT4-300E

5982C49A95

—

RBA4

38

300E

5982C64G01

4NPL-3500

5982C64G01

—

NPL

0.48

3500

5982C64G02

4NPL-5000

5982C64G02

—

NPL

0.48

5000

5982C90G01

6MDSL-A150

5982C90G01

—

DSL

0.6

150

5982C90G02

6MDSL-A200

5982C90G02

—

DSL

0.6

200

5982C90G03

6MDSL-A250

5982C90G03

—

DSL

0.6

250

5982C90G04

6MDSL-A300

5982C90G04

—

DSL

0.6

300

5982C90G05

6MDSL-A400

5982C90G05

—

DSL

0.6

400

5982C90G06

6MDSL-A600

5982C90G06

—

DSL

0.6

60

5982C90G07

6MDSL-A800

5982C90G07

—

DSL

0.6

800

5982C91G01

6MDSL-B1200

5982C91G01

—

DSL

0.6

1200

5982C91G02

6MDSL-B1600

5982C91G02

—

DSL

0.6

1600

5982C91G03

6MDSL-B2000

5982C91G03

—

DSL

0.6

2000

5982C92G01

6MDSL-C800

5982C92G01

—

DSL

0.6

800

5982C92G02

6MDSL-C1000

5982C92G02

—

DSL

0.6

1000

5982C92G03

6MDSL-C1200

5982C92G03

—

DSL

0.6

1200

5982C92G04

6MDSL-C1600

5982C92G04

—

DSL

0.6

1600

5982C92G05

6MDSL-C2000

5982C92G05

—

DSL

0.6

2000

5982C93G01

6MDSL-D2500

5982C93G01

—

DSL

0.6

2500

5982C93G02

6MDSL-D3000

5982C93G02

—

DSL

0.6

3000

5983C02G01

5BHLE-10E

5983C02G01

—

HLE

5.5

10E

5983C02G02

5BHLE-15E

5983C02G02

—

HLE

5.5

15E

5983C02G03

5BHLE-20E

5983C02G03

—

HLE

5.5

20E

5983C02G04

5BHLE-25E

5983C02G04

—

HLE

5.5

25E

5983C02G05

5BHLE-30E

5983C02G05

—

HLE

5.5

30E

5983C02G06

5BHLE-40E

5983C02G06

—

HLE

5.5

40E

5983C02G07

5BHLE-50E

5983C02G07

—

HLE

5.5

50E

5983C02G08

5BHLE-65E

5983C02G08

—

HLE

5.5

65E

5983C02G09

5BHLE-80E

5983C02G09

—

HLE

5.5

80E

5983C02G10

5BHLE-100E

5983C02G10

—

HLE

5.5

100E

5983C02G11

5BHLE-125E

5983C02G11

—

HLE

5.5

125E

5983C02G12

5BHLE-150E

5983C02G12

—

HLE

5.5

150E

5983C02G13

5BHLE-175E

5983C02G13

—

HLE

5.5

175E

5983C02G14

5BHLE-200E

5983C02G14

—

HLE

5.5

200E

5983C02G15

5BHLE-250E

5983C02G15

—

HLE

5.5

250E

5983C02G16

5BHLE-300E

5983C02G16

—

HLE

5.5

300E

5983C02G17

5BHLE-350E

5983C02G17

—

HLE

5.5

350E

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-91

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5983C02G18

5BHLE-400E

5983C02G18

5983C02G19

5BHLE-450E

5983C02G19

—

HLE

5.5

400E

—

HLE

5.5

5983C03G01

8BHLE-10E

450E

5983C03G01

—

HLE

8.3

5983C03G02

10E

8BHLE-15E

5983C03G02

—

HLE

8.3

15E

5983C03G03

8BHLE-20E

5983C03G03

—

HLE

8.3

20E

5983C03G04

8BHLE-25E

5983C03G04

—

HLE

8.3

25E

5983C03G05

8BHLE-30E

5983C03G05

—

HLE

8.3

30E

5983C03G06

8BHLE-40E

5983C03G06

—

HLE

8.3

40E

5983C03G07

8BHLE-50E

5983C03G07

—

HLE

8.3

50E

5983C03G08

8BHLE-65E

5983C03G08

—

HLE

8.3

65E

5983C03G09

8BHLE-80E

5983C03G09

—

HLE

8.3

80E

5983C03G10

8BHLE-100E

5983C03G10

—

HLE

8.3

100E

5983C03G11

8BHLE-125E

5983C03G11

—

HLE

8.3

125E

5983C03G12

8BHLE-150E

5983C03G12

—

HLE

8.3

150E

5983C03G13

8BHLE-175E

5983C03G13

—

HLE

8.3

175E

5983C03G14

8BHLE-200E

5983C03G14

—

HLE

8.3

200E

5983C03G15

8BHLE-250E

5983C03G15

—

HLE

8.3

250E

5983C03G16

8BHLE-300E

5983C03G16

—

HLE

8.3

300E

5983C03G17

8BHLE-350E

5983C03G17

—

HLE

8.3

350E

5983C08G01

8HCL-200E

5983C08G01

—

HCL

8.3

200E

5983C08G02

8HCL-250E

5983C08G02

—

HCL

8.3

250E

5983C08G03

8HCL-300E

5983C08G03

—

HCL

8.3

300E

5983C08G04

8HCL-350E

5983C08G04

—

HCL

8.3

350E

5983C08G05

8HCL-175E

5983C08G05

—

HCL

8.3

175E

5983C08G06

8HCL-150E

5983C08G06

—

HCL

8.3

150E

5983C08G07

8HCL125E

5983C08G07

—

HCL

8.3

125E

5983C08G08

8HCL-100E

5983C08G08

—

HCL

8.3

100E

5983C08G09

8HCL-80E

5983C08G09

—

HCL

8.3

80E

5983C08G10

8HCL-65E

5983C08G10

—

HCL

8.3

65E

5984C05G01

15BHLE-10E

5984C05G01

—

HLE

15.5

10E

5984C05G02

15BHLE-15E

5984C05G02

—

HLE

15.5

15E

5984C05G03

15BHLE-20E

5984C05G03

—

HLE

15.5

20E

5984C05G04

15BHLE-25E

5984C05G04

—

HLE

15.5

25E

5984C05G05

15BHLE-30E

5984C05G05

—

HLE

15.5

30E

5984C05G06

15BHLE-40E

5984C05G06

—

HLE

15.5

40E

5984C05G07

15BHLE-50E

5984C05G07

—

HLE

15.5

50E

5984C05G08

15BHLE-65E

5984C05G08

—

HLE

15.5

65E

5984C05G09

15BHLE-80E

5984C05G09

—

HLE

15.5

80E

5984C05G10

15BHLE-100E

5984C05G10

—

HLE

15.5

100E

5984C05G11

15BHLE-125E

5984C05G11

—

HLE

15.5

125E

5984C05G12

15BHLE-150E

5984C05G12

—

HLE

15.5

150E

5984C05G13

15BHLE-175E

5984C05G13

—

HLE

15.5

175E

5984C05G14

15BHLE-200E

5984C05G14

—

HLE

15.5

200E

5984C05G15

15BHLE-250E

5984C05G15

—

HLE

15.5

250E

5984C05G16

15BHLE2-40E

5984C05G16

—

HLE

15.5

40E

5984C05G17

15BHLE2-50E

5984C05G17

—

HLE

15.5

50E

5984C05G18

15BHLE2-65E

5984C05G18

—

HLE

15.5

65E

5984C05G19

15BHLE2-80E

5984C05G19

—

HLE

15.5

80E

5984C05G20

15BHLE2-100E

5984C05G20

—

HLE

15.5

100E

5984C05G21

15BHLE2-125E

5984C05G21

—

HLE

15.5

125E

5984C17G01

8RBA4-INH-B

5984C17G01

—

RBA4

8.3

400

5984C17G02

15RBA4-INH-B

5984C17G02

—

RBA4

15.5

400

5984C17G03

25RBA4-INH-B

5984C17G03

—

RBA4

25.5

300

V14-A2-92

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5984C17G04

38RBA4-INH-B

5984C17G04

5094C18G01

8RBA2-INH-B

5094C18G01

—

RBA4

38

300

—

RBA2

8.3

5094C18G02

15RBA2-INH-B

200

5094C18G02

—

RBA2

15.5

5094C18G03

200

25RBA2-INH-B

5094C18G03

—

RBA2

25.5

200

5094C18G04

38RBA2-INH-B

5094C18G04

—

RBA2

38

200

5984C25G01

DBU17-GNMP-L

5984C25G01

—

DBU

17

200

5984C25G02

DBU27-GNMP-L

5984C25G02

—

DBU

27

200

5984C25G03

DBU38-GNMP-L

5984C25G03

—

DBU

38

200

5984C25G04

DBU17-GNMP-R

5984C25G04

—

DBU

17

200

5984C25G05

DBU27-GNMP-R

5984C25G05

—

DBU

27

200

5984C25G06

DBU38-GNMP-R

5984C25G06

—

DBU

38

200

5984C25G07

DBU17-GNM-L

5984C25G07

—

DBU

17

200

5984C25G08

DBU27-GNM-L

5984C25G08

—

DBU

27

200

5984C25G09

DBU38-GNM-L

5984C25G09

—

DBU

38

200

5984C25G10

DBU17-GNM-R

5984C25G10

—

DBU

17

200

5984C25G11

DBU27-GNM-R

5984C25G11

—

DBU

27

200

5984C25G12

DBU38-GNM-R

5984C25G12

—

DBU

38

200

5984C29G01

DBU17-NL-L

5984C29G01

—

DBU

17

200

5984C29G02

DBU27-NL-L

5984C29G02

—

DBU

27

200

5984C29G03

DBU38-NL-L

5984C29G03

—

DBU

38

200

5984C29G04

DBU17-NL-R

5984C29G04

—

DBU

17

200

5984C29G05

DBU27-NL-R

5984C29G05

—

DBU

27

200

5984C29G06

DBU38-NL-R

5984C29G06

—

DBU

38

200

5984C29G07

DBU17-NLP-L

5984C29G07

—

DBU

17

200

5984C29G08

DBU27-NLP-L

5984C29G08

—

DBU

27

200

5984C29G09

DBU38-NLP-L

5984C29G09

—

DBU

38

200

5984C29G10

DBU17-NLP-R

5984C29G10

—

DBU

17

200

5984C29G11

DBU27-NLP-R

5984C29G11

—

DBU

27

200

5984C29G12

DBU38-NLP-R

5984C29G12

—

DBU

38

200

5984C38G01

DBU27-DM

5984C38G01

—

DBU

17

200

5984C39G01

DBU17-DM

5984C39G01

—

DBU

27

200

5984C50G01

5HME-40E

5984C50G01

—

HME

5.5

40E

5984C50G02

5HME-125E

5984C50G02

—

HME

5.5

125E

5984C50G04

5CME-40E

5984C50G04

—

CME

5.5

40E

5984C50G05

5CME-125E

5984C50G05

—

CME

5.5

125E

5984C50G06

5CME-200E

5984C50G06

—

CME

5.5

200E

5984C50G21

5BHME-40E

5984C50G21

—

HME

5.5

40E

5984C50G22

5BHME-125E

5984C50G22

—

HME

5.5

125E

5984C50G24

5BCME-40E

5984C50G24

—

CME

5.5

40E

5984C50G25

5BCME-125E

5984C50G25

—

CME

5.5

125E

5984C50G26

5BCME-200E

5984C50G26

—

CME

5.5

200E

5984C56G01

5MCLS-30-A

5984C56G01

—

CLS

5.08

30

5984C56G02

5MCLS-2R-A

5984C56G02

—

CLS

5.08

2R(70)

5984C56G03

5MCLS-3R-A

5984C56G03

—

CLS

5.08

3R(100)

5984C56G04

5MCLS-4R-A

5984C56G04

—

CLS

5.08

4R(130)

5984C56G05

5MCLS-5R-A

5984C56G05

—

CLS

5.08

5R(150)

5984C56G06

5MCLS-5R-A

5984C56G06

—

CLS

5.08

6R(170)

5984C56G09

5MCLS-8R-A

5984C56G09

—

CLS

5.08

9R(200)

5984C56G12

5MCLS-12R-A

5984C56G12

—

CLS

5.08

12R(230)

5984C56G18

5MCLS-18R-A

5984C56G18

—

CLS

5.08

18R(390)

5984C56G24

5MCLS-24R-A

5984C56G24

—

CLS

5.08

24R(450)

5984C56G36

5MCLS-36R-A

5984C56G36

—

CLS

5.08

36R(650)

5984 C57G01

5MCLS-30-B

5984 C57G01

—

CLS

5.08

30

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-93

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

5984 C57G02

5MCLS-2R-B

5984 C57G02

5984 C57G03

5MCLS-3R-B

5984 C57G03

—

CLS

5.08

2R(70)

—

CLS

5.08

5984 C57G04

5MCLS-4R-B

3R(100)

5984 C57G04

—

CLS

5.08

5984 C57G05

4R(130)

5MCLS-5R-B

5984 C57G05

—

CLS

5.08

5R(150)

5984 C57G06

5MCLS-5R-B

5984 C57G06

—

CLS

5.08

6R(170)

5984 C57G09

5MCLS-8R-B

5984 C57G09

—

CLS

5.08

9R(200)

5984 C57G12

5MCLS-12R-B

5984 C57G12

—

CLS

5.08

12R(230)

5984 C57G18

5MCLS-18R-B

5984 C57G18

—

CLS

5.08

18R(390)

5984 C57G24

5MCLS-24R-B

5984 C57G24

—

CLS

5.08

24R(450)

5984 C57G36

5MCLS-36R-B

5984 C57G36

—

CLS

5.08

36R(650)

5984C65G01

15LHLE-65E

5984C65G01

—

HLE

15.5

65E

5984C65G02

15LHLE-80E

5984C65G02

—

HLE

15.5

80E

5984C65G03

15LHLE-100E

5984C65G03

—

HLE

15.5

100E

5984C65G04

15LHLE2-125E

5984C65G04

—

HLE

15.5

125E

5984C65G05

15LHLE2-150E

5984C65G05

—

HLE

15.5

150E

5984C65G06

15LHLE-175E

5984C65G06

—

HLE

15.5

175E

5984C65G07

15LHLE-200E

5984C65G07

—

HLE

15.5

200E

5984C65G08

15LHLE-125E

5984C65G08

—

HLE

15.5

125E

5984C65G09

15LHLE-150E

5984C65G09

—

HLE

15.5

150E

5984C65G10

15LHLE-250E

5984C65G10

—

HLE

15.5

250E

5984C65G11

15LHLE-300E

5984C65G11

—

HLE

15.5

300E

60A1307G01

Obsolete—contact Eaton

—

4.8 kV RBA-800 mounting

—

—

—

60A1307G02

Obsolete—contact Eaton

—

7.2 kV RBA-800 mounting

—

—

—

60A1307G03

Obsolete—contact Eaton

—

13.2 kV RBA-800 mounting

—

—

—

60A1307G04

Obsolete—contact Eaton

—

14.4 kV RBA-800 mounting

—

—

—

6379D26H01

Obsolete—contact Eaton

—

5ACLS-.5R (10A)

—

—

—

6379D26H02

Obsolete—contact Eaton

—

5ACLS-.75R (20A)

—

—

—

6379D26H03

5ACLS-30

449D597G01

—

CLS

5.08

30

6379D26H04

Obsolete—contact Eaton

—

5ACLS-1.5R (40A)

CLS

5.08

2R(70)

6379D26H05

5ACLS-2R (70A)

449D597G02

—

CLS

5.08

3R(100)

6379D26H06

5ACLS-3R (100A)

449D597G03

—

CLS

5.08

4R(130)

6379D26H07

5ACLS-4R (130A)

449D597G04

—

CLS

5.08

5R(150)

6379D26H08

5ACLS-5R (150A)

449D597G05

—

CLS

5.08

6R(170)

6379D26H09

5ACLS-6R (170A)

449D597G06

—

CLS

5.08

9R(200)

6379D26H12

5ACLS-9R (200A)

151D933G01

—

CLS

5.08

12R(230)

6379D26H15

5ACLS-12R (230A)

151D933G02

—

CLS

5.08

18R(390)

6369D26H20

5ACLS-19R (390A)

151D933G03

—

CLS

5.08

24R(450)

6379D28H24

5ACLS-24R (450A)

151D933G04

—

—

—

—

6379D26H26

Obsolete—contact Eaton

—

—

—

—

—

6379D26H28

Obsolete—contact Eaton

—

—

—

—

—

6379D26H30

Obsolete—contact Eaton

—

—

—

—

—

676C231A10

Obsolete—contact Eaton

—

2.4 kV rear connected disc. CLE mounting

—

—

—

676C231A11

Obsolete—contact Eaton

—

4.8 kV rear connected disc. CLE mounting

—

—

—

676C231A13

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLE mounting

—

—

—

676C231A15

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLE mounting

—

—

—

676C231A16

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLE mounting

—

—

—

676C231A18

Obsolete—contact Eaton

—

2.4 kV rear connected disc. CLE mounting

—

—

—

676C231A19

Obsolete—contact Eaton

—

4.8 kV rear connected disc. CLE mounting

—

—

—

676C231A21

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLE mounting

—

—

—

676C231A23

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLE mounting

—

—

—

676C231A24

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLE mounting

—

—

—

676C231A26

Obsolete—contact Eaton

—

2.4 kV rear connected disc. CLE mounting

—

—

—

676C231A27

Obsolete—contact Eaton

—

4.8 kV rear connected disc. CLE mounting

—

—

—

V14-A2-94

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

676C231A29

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLE mounting

—

—

—

676C231A31

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLE mounting

—

—

—
—

676C231A32

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLE mounting

—

—

676C232G07

CLPT-DL

9078A64G01

—

CLPT

—

10

676C233A09

Obsolete—contact Eaton

—

4.8 kV rear connected disc. CLPT mounting

—

—

—

676C233A10

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLPT mounting

—

—

—

676C233A12

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLPT mounting

—

—

—

676C233A13

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLPT mounting

—

—

—

676C233A14

Obsolete—contact Eaton

—

23 kV rear connected disc. CLPT mounting

—

—

—

676C233A17

Obsolete—contact Eaton

—

4.8 kV rear connected disc. CLPT mounting

—

—

—

676C233A18

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLPT mounting

—

—

—

676C233A20

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLPT mounting

—

—

—

676C233A21

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLPT mounting

—

—

—

676C233A22

Obsolete—contact Eaton

—

23 kV rear connected disc. CLPT mounting

—

—

—

676C233A25

Obsolete—contact Eaton

—

4.8 kV rear connected disc. CLPT mounting

—

—

—

676C233A26

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLPT mounting

—

—

—

676C233A28

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLPT mounting

—

—

—

676C233A29

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLPT mounting

—

—

—

676C233A30

Obsolete—contact Eaton

—

23 kV rear connected disc. CLPT mounting

—

—

—

676C234A09

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLPT mounting

—

—

—

676C234A11

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLPT mounting

—

—

—

676C234A12

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLPT mounting

—

—

—

676C234A17

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLPT mounting

—

—

—

676C234A19

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLPT mounting

—

—

—

676C234A20

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLPT mounting

—

—

—

676C234A26

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLPT mounting

—

—

—

676C234A28

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLPT mounting

—

—

—

676C234A29

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLPT mounting

—

—

—

676C236A11

Obsolete—contact Eaton

—

4.8 kV rear connected disc. CLPT mounting

—

—

—

676C236A12

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLPT mounting

—

—

—

676C236A14

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLPT mounting

—

—

—

676C236A15

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLPT mounting

—

—

—

676C236A16

Obsolete—contact Eaton

—

23 kV rear connected disc. CLPT mounting

—

—

—

676C236A21

Obsolete—contact Eaton

—

4.8 kV rear connected disc. CLPT mounting

—

—

—

676C236A22

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLPT mounting

—

—

—

676C236A24

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLPT mounting

—

—

—

676C236A25

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLPT mounting

—

—

—

676C236A26

Obsolete—contact Eaton

—

23 kV rear connected disc. CLPT mounting

—

—

—

676C237A11

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLPT mounting

—

—

—

676C237A13

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLPT mounting

—

—

—

676C237A14

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLPT mounting

—

—

—

676C237A21

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLPT mounting

—

—

—

676C237A23

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLPT mounting

—

—

—

676C237A24

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLPT mounting

—

—

—

676C238A12

Obsolete—contact Eaton

—

2.4 kV rear connected disc. CLE-C mounting

—

—

—

676C238A13

Obsolete—contact Eaton

—

4.8 kV rear connected disc. CLE-C mounting

—

—

—

676C238A15

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLE-C mounting

—

—

—

676C238A17

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLE-C mounting

—

—

—

676C238A18

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLE-C mounting

—

—

—

676C238A22

Obsolete—contact Eaton

—

2.4 kV rear connected disc. CLE-C mounting

—

—

—

676C238A23

Obsolete—contact Eaton

—

4.8 kV rear connected disc. CLE-C mounting

—

—

—

676C238A25

Obsolete—contact Eaton

—

7.2 kV rear connected disc. CLE-C mounting

—

—

—

676C238A27

Obsolete—contact Eaton

—

13.8 kV rear connected disc. CLE-C mounting

—

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-95

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes
—

676C238A28

Obsolete—contact Eaton

—

14.4 kV rear connected disc. CLE-C mounting

—

—

676C436G14

5CLE-40E

5981C65G01

—

CLE

5.5

40E

676C546G02

2CLS-2R

591C812G02

—

CLS

2.54

2R(70)

676C546G03

2CLS-3R

591C812G03

—

CLS

2.54

3R(100)

676C546G04

2CLS-4R

591C812G04

—

CLS

2.54

4R(130)

676C546G05

2CLS-5R

591C812G05

—

CLS

2.54

5R(150)

676C546G06

2CLS-6R

591C812G06

—

CLS

2.54

6R(170)

676C546G09

2CLS-9R

591C812G07

—

CLS

2.54

9R(200)

676C546G12

2CLS-12R

591C812G08

—

CLS

2.54

12R(230)

676C546G14

5CLE-40E

5981C65G01

—

CLE

5.5

40E

676C546G15

5LCLS-2R

676C546G15

—

CLS

2.54

2R(70)

676C546G16

5LCLS-3R

676C546G16

—

CLS

2.54

3R(100)

676C546G17

5LCLS-4R

676C546G17

—

CLS

2.54

4R(130)

676C546G18

5LCLS-5R

676C546G18

—

CLS

2.54

5R(150)

676C546G19

5LCLS-6R

676C546G19

—

CLS

2.54

6R(170)

676C546G22

5LCLS-9R

676C546G22

—

CLS

2.54

9R(200)

676C546G25

5LCLS-12R

676C546G25

—

CLS

2.54

12R(230)

676C774G10

Obsolete—contact Eaton

—

CLE rear connected live parts

—

—

—

676C774G11

Obsolete—contact Eaton

—

CLE rear connected live parts

—

—

—

676C774G14

Obsolete—contact Eaton

—

CLE rear connected live parts

—

—

—

676C776A02

2CLE-PNM-D

9078A68G15

—

CLE

2.75

250

676C776A03

5CLE-PNM-D

9078A68G16

—

CLE

5.5

250

676C776A05

8CLE-PNM-D

9078A68G17

—

CLE

8.3

175

676C776A07

15CLE-PNM-D

9078A68G18

—

CLE

15.5

150

676C776A11

Obsolete—contact Eaton

—

2.4 kV rear connected CLE-D mounting

—

—

—

676C776A12

Obsolete—contact Eaton

—

4.8 kV rear connected CLE-D mounting

—

—

—
—

676C776A14

Obsolete—contact Eaton

—

7.2 kV rear connected CLE-D mounting

—

—

676C776A16

Obsolete—contact Eaton

—

14.4 kV rear connected CLE-D mounting

—

—

—

676C776A20

Obsolete—contact Eaton

—

2.4 kV rear connected CLE-D mounting

—

—

—

676C776A21

Obsolete—contact Eaton

—

4.8 kV rear connected CLE-D mounting

—

—

—

676C776A23

Obsolete—contact Eaton

—

7.2 kV rear connected CLE-D mounting

—

—

—

676C776A25

Obsolete—contact Eaton

—

14.4 kV rear connected CLE-D mounting

—

—

—

676C880G01

8RBA2-NH

5981C51G01

—

RBA2

8.3

200

676C880G02

15RBA2-NH

5981C51G02

—

RBA2

15.5

200

676C880G03

25RBA2-NH

5981C51G03

—

RBA2

25.5

200

676C880G04

38RBA2-NH

5981C51G04

—

RBA2

38

200

677C370G01

8RBA2-NH

5981C51G01

—

RBA2

8.3

200

677C370G02

15RBA2-NH

5981C51G02

—

RBA2

15.5

200

677C370G03

25RBA2-NH

5981C51G03

—

RBA2

25.5

200

677C370G04

38RBA2-NH

5981C51G04

—

RBA2

38

200

677C371G01

8RBA4-NH

5981C53G01

—

RBA4

8.3

400

677C371G02

15RBA4-NH

5981C53G02

—

RBA4

15.5

400

677C371G03

25RBA4-NH

5981C53G03

—

RBA4

25.5

300

677C371G04

38RBA4-NH

5981C53G04

—

RBA4

38

300

677C452G01

5CLPT-.5E

677C452G01

—

CLPT

5.5

0.5

677C452G02

8CLPT-.5E

677C452G02

—

CLPT

8.3

0.5

677C452G03

15CLPT-.5E

677C452G03

—

CLPT

15.5

0.5

677C452G04

25CLPT-.5E

677C452G04

—

CLPT

25.5

0.5

677C452G05

38CLPT-.5E

677C452G05

—

CLPT

38

0.5

677C452G06

5CLPT-1E

677C452G06

—

CLPT

5.5

1

677C452G08

15CLPT-1E

677C452G08

—

CLPT

15.5

1

677C452G09

25CLPT-1E

677C452G09

—

CLPT

25.5

1

677C452G10

15CLPT-1.5E

677C452G10

—

CLPT

15.5

1.5

V14-A2-96

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

677C452G11
677C453G01

5CLPT-1.5E

677C452G11

5CLPT-5E

677C453G01

—

CLPT

5.5

1.5

—

CLPT

5.5

677C453G02

8CLPT-5E

5E

677C453G02

—

CLPT

8.3

677C453G03

5E

15CLPT-5E

677C453G03

—

CLPT

15.5

5E

677C453G04

5CLPT-10E

677C453G04

—

CLPT

5.5

10E

677C453G05

8CLPT-10E

677C453G05

—

CLPT

8.3

10E

677C453G06

15CLPT-10E

677C453G06

—

CLPT

15.5

10E

677C453G07

5CLPT-3E

677C453G07

—

CLPT

5.5

3E

677C453G08

8CLPT-3E

677C453G08

—

CLPT

8.3

3E

677C453G09

15CLPT-3E

677C453G09

—

CLPT

15.5

3E

677C573G01

8CLE-30E

5981C31G05

—

CLE

8.3

30E

677C573G02

8CLE-40E

5981C17G04

—

CLE

8.3

40E

677C573G03

8CLE-50E

5981C17G05

—

CLE

8.3

50E

677C573G04

8CLE-65E

5981C17G06

—

CLE

8.3

65E

677C573G05

8CLE-80E

5981C17G07

—

CLE

8.3

80E

677C573G06

8CLE-100E

5981C17G08

—

CLE

8.3

100E

677C573G07

8CLE-125E

5981C17G09

—

CLE

8.3

125E

677C574G01

8CLE-150E

5981C17G10

—

CLE

8.3

150E

677C574G02

8CLE-200E

5981C23G01

—

CLE

8.3

200E

677C574G04

8CLE-100E

5981C17G08

—

CLE

8.3

100E

677C578G01

5LCLS-18R

304C463G01

—

CLS

5.08

18R(390)

677C578G02

5LCLS-24R

304C463G02

—

CLS

5.08

24R(450)

677C579G02

5CLE-50E

5981C65G02

—

CLE

5.5

50E

677C579G03

5CLE-65E

5981C65G03

—

CLE

5.5

65E

677C579G04

5CLE-80E

5981C65G04

—

CLE

5.5

80E

677C579G05

5CLE100E

5981C65G05

—

CLE

5.5

100E

677C579G06

5CLE-125E

5981C65G06

—

CLE

5.5

125E

677C579G07

5CLE-150E

5981C65G07

—

CLE

5.5

150E

677C579G08

5CLE-200E

5981C65G08

—

CLE

5.5

200E

677C579G09

Obsolete—contact Eaton

—

5CLE1-225E

—

—

—

677C579G10

5CLE-30E

5981C29G05

—

CLE

5.5

30E

677C580G01

5CLE-250E

5981C65G09

—

CLE

5.5

250E

677C580G02

5CLE-300E

5981C67G01

—

CLE

5.5

300E

677C580G03

5CLE-350E

5981C67G02

—

CLE

5.5

350E

677C580G04

Obsolete—contact Eaton

—

5CLE2-365E

—

—

—

677C580G05

5CLE-400E

5981C67G03

—

CLE

5.5

400E

677C591G01

2CLE-10E

5981C29G01

—

CLE

2.75

10E

677C592G01

2NCLPT-.25E

677C592G01

—

CLPT

2.75

0.25E

677C592G02

2NCLPT-.5E

677C592G02

—

CLPT

2.75

0.5E

677C592G03

2NCLPT-1E

677C592G03

—

CLPT

2.75

1E

677C592G04

2NCLPT-2E

677C592G04

—

CLPT

2.75

2E

677C592G05

5NCLPT-.5E

7186A29G01

—

CLPT

5.5

0.5E

677C592G06

Obsolete—contact Eaton

—

5NCLPT-0.25E

—

—

—

677C592G07

2NCLPT-.5E

677C592G07

—

CLPT

2.75

.5E

677C592G08

2NCLPT-5E

677C592G08

—

CLPT

2.75

5E

677C592G09

5NCLPT-2E

7186A29G03

—

CLPT

5.5

2E

677C592G10

8NCLPT-2E

677C592G10

—

CLPT

8.3

2E

677C592G11

8NCLPT-4E

677C592G11

—

CLPT

8.3

4E

677C592G12

5NCLPT-4E

7186A29G05

—

CLPT

5.5

4E

677C593G01

Obsolete—contact Eaton

—

6CLV-2E

—

—

—

677C593G02

Obsolete—contact Eaton

—

6CLV-5E

—

—

—

677C593G03

Obsolete—contact Eaton

—

6CLV-7E

—

—

—

677C593G04

Obsolete—contact Eaton

—

6CLV-10E

—

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-97

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

677C593G05

Obsolete—contact Eaton

—

6CLV-15

—

—

—

677C593G06

Obsolete—contact Eaton

—

6CLV-20

—

—

—

677C605G01

Obsolete—contact Eaton

—

8BA8-NH

—

—

—

677C605G02

Obsolete—contact Eaton

—

15BA8-NH

—

—

—

677C605G03

Obsolete—contact Eaton

—

25BA8-NH

—

—

—

677C605G04

Obsolete—contact Eaton

—

38BA8-NH

—

—

—

678C240G01

2CLE-15E

678C240G01

—

CLE

2.75

15E

678C240G02

2CLE-20E

678C240G02

—

CLE

2.75

20E

678C240G03

2CLE-25E

678C240G03

—

CLE

2.75

25E

678C240G04

5CLE-15E

678C240G04

—

CLE

5.5

15E

678C240G05

5CLE-20E

678C240G05

—

CLE

5.5

20E

678C240G06

5CLE-25E

678C240G06

—

CLE

5.5

25E

678C240G07

8CLE-15E

678C240G07

—

CLE

8.3

15E

678C240G08

8CLE-20E

678C240G08

—

CLE

8.3

20E

678C240G09

8CLE-25E

678C240G09

—

CLE

8.3

25E

678C240G10

15CLE-15E

678C240G10

—

CLE

15.5

15E

678C240G11

15CLE-20E

678C240G11

—

CLE

15.5

20E

678C240G12

15CLE-25E

678C240G12

—

CLE

15.5

25E

678C245G01

Obsolete—contact Eaton

—

8CLTB-20

—

—

—

678C245G02

Obsolete—contact Eaton

—

15CLTB-30

—

—

—

678C245G03

Obsolete—contact Eaton

—

12CLTB-30

—

—

—

678C248G01

2CLT-5

678C248G01

—

CLT

2.75

5

678C248G03

8CLT-5

678C248G03

—

CLT

8.3

5

678C248G05

5CLT-8

678C248G05

—

CLT

5.5

8

678C248G06

8CLT-8

678C248G06

—

CLT

8.3

8

678C249G01

2CLT-12

678C249G01

—

CLT

2.75

12

678C249G03

5CLT-12

678C249G03

—

CLT

5.5

12

678C276G01

2CLT-18

678C276G01

—

CLT

2.75

18

678C276G02

5CLT-18

678C276G02

—

CLT

5.5

18

678C276G03

8CLT-18

678C276G03

—

CLT

8.3

18

678C276G04

2CLT-25

678C276G04

—

CLT

2.75

25

678C276G05

5CLT-25

678C276G05

—

CLT

5.5

25

678C276G06

8CLT-25

678C276G06

—

CLT

8.3

25

678C277G01

2CLT-30

678C277G01

—

CLT

2.75

30

678C281G02

5CLE-15E

678C240G04

—

CLT

5.5

15

678C282G01

2CLT-75

678C282G01

—

CLT

2.75

75

678C283G01

8RBA4-SHNT

678C283G01

—

RBA4

8.3

400

678C283G02

15RBA4-SHNT

678C283G02

—

RBA5

15.5

400

678C283G03

25RBA4-SHNT

678C283G03

—

RBA6

25.5

300

678C283G04

38RBA4-SHNT

678C283G04

—

RBA7

38

300

678C283G05

8RBA4-ISHNT

678C283G05

—

RBA8

8.3

400

678C283G06

15RBA4-ISHNT

678C283G06

—

RBA9

15.5

400

678C283G07

25RBA4-ISHNT

678C283G07

—

RBA10

25.5

300

678C283G08

38RBA4-ISHNT

678C283G08

—

RBA11

38

300

678C284G01

8RDB4-SHNT

678C284G01

—

RBA12

8.3

400

678C284G02

15RDB4-SHNT

678C284G02

—

RBA13

15.5

400

678C284G03

25RDB4-SHNT

678C284G03

—

RBA14

25.5

300

678C284G04

38RDB4-SHNT

678C284G04

—

RBA15

38

300

678C290G01

8CLT-30CL

678C290G01

—

CLT

8.3

30

678C292G01

2CLE-450X

449D797G18

—

CLE

2.75

450X

678C292G02

5CLE-450E

5981C67G04

—

CLE

5.5

450E

678C292G03

5CLE-400E

5981C67G03

—

CLE

5.5

400E

678C295G02

15CLT-12

678C295G02

—

CLT

15.5

12

V14-A2-98

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

678C295G03

15CLT-8

678C295G03

678C295G04

15CLT-5

678C295G04

—

CLT

15.5

8

—

CLT

15.5

678C295G05

15CLT-4

5

678C295G05

—

CLT

15.5

678C295G07

4

15CLT-10

678C295G07

—

CLT

15.5

10

678C305G01

Obsolete—contact Eaton

—

5NCLPT-5E special

—

—

—

678C310G01

5AHLE-30E

5981C46G05

—

HLE

5.5

30E

678C310G02

5AHLE-50E

5981C46G07

—

HLE

5.5

50E

678C310G03

5AHLE-65E

5981C46G08

—

HLE

5.5

65E

678C310G04

5AHLE-80E

5981C46G09

—

HLE

5.5

80E

678C310G05

5AHLE-100E

5981C46G10

—

HLE

5.5

100E

678C310G06

5AHLE-125E

5981C46G11

—

HLE

5.5

125E

678C310G07

5AHLE-150E

5981C46G12

—

HLE

5.5

150E

678C310G08

5AHLE-200E

5981C46G14

—

HLE

5.5

200E

678C310G09

Obsolete—contact Eaton

—

5ACLE-225E

—

—

—

680C386G01

8CLT30-CS

680C386G01

—

CLT

8.3

30

680C386G02

5CLT-30

680C386G02

—

CLT

5.5

30

680C386G03

5CLT-60

680C386G03

—

CLT

5.5

60

680C386G04

Obsolete—contact Eaton

—

8CLT-60

—

—

—

680C386G05

5CLT-45

680C386G05

—

CLT

5.5

45

680C386G06

8CLT-45

680C386G06

—

CLT

8.3

45

680C387G01

2CLT-150

680C387G01

—

CLT

2.75

150

680C387G02

2CLT-90

680C387G02

—

CLT

2.75

90

6911D50G02

Obsolete—contact Eaton

—

15CLTX-15K—spade-to-spade

—

—

—

6911D50G03

Obsolete—contact Eaton

—

8CLTX-15K—spade-to-spade

—

—

—

6911D50G04

Obsolete—contact Eaton

—

8CLTX-40K—spade-to-spade

—

—

—

6911D50G05

Obsolete—contact Eaton

—

15CLTX-40K—spade-to-spade

—

—

—

6911D50G06

Obsolete—contact Eaton

—

23CLTX-15K—spade-to-spade

—

—

—

6911D50G07

Obsolete—contact Eaton

—

8CLTX-25K—spade-to-spade

—

—

—

6911D50G08

Obsolete—contact Eaton

—

15CLTX-25K—spade-to-spade

—

—

—

692C771G01

Obsolete—contact Eaton

—

DBU condenser

—

—

—

7184A64G01

5CLE-30E

5981C29G05

LCU 30E<=>5CLE-30E fuse private labelled for Littelfuse

—

—

—

7184A64G02

5CLE-50E

5981C65G02

LCU 50E<=>5CLE-50E fuse private labelled for Littelfuse

—

—

—

7184A64G03

5CLE-100E

5981C65G05

LCU 100E<=>5CLE-100E fuse private labelled for
Littelfuse

—

—

—

7184A64G04

5CLE-150E

5981C65G07

LCU 150E<=>5CLE-150E fuse private labelled for
Littelfuse

—

—

—

7184A64G05

5CLE-200E

5981C65G09

LCU 200E<=>5CLE-200E fuse private labelled for
Littelfuse

—

—

—

7184A64G06

Obsolete—contact Eaton

—

LCU 225E<=>5CLE1-225E fuse private labelled for
Littelfuse

—

—

—

7184A64G07

5CLE-300E

5981C67G01

LCU 300E<=>5CLE-300E fuse private labelled for
Littelfuse

—

—

—

7184A64G08

5HLE-400E

5981C66G03

LCY 400E<=>5HLE-400E fuse private labelled for
Littelfuse

—

—

—

7184A64G09

5CLE-400E

5981C67G03

LCU 400E<=>5CLE-400E fuse private labelled for
Littelfuse

—

—

—

7184A64G10

5CLE-600E

449D595G02

LCU 600E<=>5CLE-600E fuse private labelled for
Littelfuse

—

—

—

7184A64G11

5CLE-750E

449D595G01

LCU 750E<=>5CLE-750E fuse private labelled for
Littelfuse

—

—

—

7184A64G12

15CLE-30E

5981C33G05

LCN 30E<=>5CLE-30E fuse private labelled for Littelfuse

—

—

—

7184A64G13

15CLE-40E

5981C65G01

LCN 34E<=>5CLE-34E fuse private labelled for Littelfuse

—

—

—

7184A64G14

15CLE-50E

5981C65G02

LCN 50E<=>5CLE-35E fuse private labelled for Littelfuse

—

—

—

7184A64G15

15CLE-65E

5981C65G03

LCN 65E<=>5CLE-65E fuse private labelled for Littelfuse

—

—

—

7184A64G16

15CLE2-80E

439D482G04

LCN 80E<=>5CLE-80E fuse private labelled for Littelfuse

—

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-99

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

7184A64G17

15CLE2-100E

7184A64G18

439D482G05

LCN 100E<=>5CLE-100E fuse private labelled for
Littelfuse

—

—

—

15CLE2-125E

439D482G06

LCN 125E<=>5CLE-125E fuse private labelled for
Littelfuse

—

—

—

7184A64G19

15CLE3-150E

591C376G02

LCN 150E<=>5CLE-150E fuse private labelled for
Littelfuse

—

—

—

7184A64G20

15CLE3-175E

591C376G01

LCN 175E<=>5CLE-175E fuse private labelled for
Littelfuse

—

—

—

7184A64G21

2CLE-10E

449D797G11

LCX 10E<=>2CLE-10E fuse private labelled for Littelfuse

—

—

—

7184A64G22

2CLE-15E

678C240G01

LCX 15E<=>2CLE-15E fuse private labelled for Littelfuse

—

—

—

7184A64G23

2CLE-30E

449D797G02

LCX 30E<=>2CLE-30E fuse private labelled for Littelfuse

—

—

—

7184A64G24

2CLE-250E

449D797G13

LCX 250E<=>2CLE-250E fuse private labelled for Littelfuse —

—

—

7184A64G25

5HLE-65E

5981C64G03

LCY 65E<=>5HLE-65E fuse private labelled for Littelfuse

—

—

—

7184A64G26

5HLE-80E

5981C64G04

LCY 80E<=>5HLE-80E fuse private labelled for Littelfuse

—

—

—

7184A64G27

5HLE-100E

5981C64G05

LCY 100E<=>5HLE-100E fuse private labelled for
Littelfuse

—

—

—

7184A64G28

5HLE-125E

5981C64G06

LCY 125E<=>5HLE-125E fuse private labelled for
Littelfuse

—

—

—

7184A64G29

5HLE-150E

5981C64G07

LCY 150E<=>5HLE-150E fuse private labelled for
Littelfuse

—

—

—

7184A64G30

5HLE-200E

5981C64G09

LCY 200E<=>5HLE-200E fuse private labelled for
Littelfuse

—

—

—

7184A64G31

5CLE-200E

5981C65G09

LCU 200E<=>5CLE-200E fuse private labelled for
Littelfuse

—

—

—

7184A64G32

8CLE-20E

678C140G08

LCZ 20E<=>8CLE-20E fuse private labelled for Littelfuse

—

—

—

7184A64G33

2CLE-65E

449D797G04

LCX 65E<=>2CLE-65E fuse private labelled for Littelfuse

—

—

—

7184A64G34

2CLE-400X

449D797G17

LCX400X<=>2CLE-400X fuse private labelled for Littelfuse —

—

—

7184A64G35

2CLE-20E

678C240G02

LCX 20E<=>2CLE-20E fuse private labelled for Littelfuse

—

—

—

7184A64G36

2CLE-25E

678C240G03

LCX 25E<=>2CLE-25E fuse private labelled for Littelfuse

—

—

—

7184A64G37

2CLE-50E

449D797G03

LCX 50E<=>2CLE-50E fuse private labelled for Littelfuse

—

—

—

7184A64G38

2CLE80E

449D797G05

LCX 80E<=>2CLE-80E fuse private labelled for Littelfuse

—

—

—

7184A64G39

2CLE-100E

449D797G06

LCX 100E<=>2CLE-100E fuse private labelled for Littelfuse —

—

—

7184A64G40

2CLE-125E

449D797G07

LCX 125E<=>2CLE-125E fuse private labelled for Littelfuse —

—

—

7184A64G41

2CLE-150E

449D797G08

LCX 150E<=>2CLE-150E fuse private labelled for Littelfuse —

—

—

7184A64G42

2CLE-200E

449D797G09

LCX 200E<=>2CLE-200E fuse private labelled for Littelfuse —

—

—

7184A64G43

2CLE-300E

449D797G14

LCX 300E<=>2CLE-300E fuse private labelled for Littelfuse —

—

—

7184A64G44

5CLE-65E

5981C65G03

LCU 65E<=>5CLE-65E fuse private labelled for Littelfuse

—

—

—

7184A64G45

5CLE-80E

5981C65G04

LCU 80E<=>5CLE-80E fuse private labelled for Littelfuse

—

—

—

7184A65G01

2NCLPT-.5E

677C592G02

LCD -1/2E-4<=>2NCLPT-.5E fuse private labelled for
Littelfuse

—

—

—

7184A65G02

2NCLPT--1E

677C592G03

LCD -1E-4<=>2NCLPT-1E fuse private labelled for
Littelfuse

—

—

—

7184A65G03

2NCLPT-2E

677C592G04

LCD -2E-4<=>2NCLPT-2E fuse private labelled for
Littelfuse

—

—

—

7184A65G04

2NCLPT-5E

677C592G08

LCD -5E-4<=>2NCLPT-5E fuse private labelled for
Littelfuse

—

—

—

7184A65G05

5CLPT-.5E

677C452G01

LCQ -1/2E-<=>5CLPT-.5E fuse private labelled for
Littelfuse

—

—

—

7184A65G06

5NCLPT-.5E

7186A29G01

LCE -1/2E-4<=>5NCLPT-.5E fuse private labelled for
Littelfuse

—

—

—

7184A65G07

5CLPT-1E

677C452G01

LCQ -1E-<=>5CLPT-1E fuse private labelled for Littelfuse

—

—

—

7184A65G08

5NCLPT-2E

7186A29G03

LCE -2E-4<=>5NCLPT-2E fuse private labelled for
Littelfuse

—

—

—

7184A65G09

5CLPT-5E

677C453G01

LCQ -5E-<=>5CLPT-5E fuse private labelled for Littelfuse

—

—

—

7184A65G10

5CLPT-10E

677C453G04

LCQ -10E-<=>5CLPT-10E fuse private labelled for
Littelfuse

—

—

—

7184A65G11

8CLPT-.5E

677C452G02

LCQ -1/2E-<=>8CLPT-.5E fuse private labelled for
Littelfuse

—

—

—

V14-A2-100

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current
Rating
Amperes

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

7184A65G12

15CLPT-.5E

7184A65G13
7184A65G14

677C452G03

LCT -1/2E-<=>15CLPT-.5E fuse private labelled for
Littelfuse

—

—

—

15CLPT-1E

677C452G08

LCT -1E-<=>15CLPT-1E fuse private labelled for Littelfuse —

—

—

15CLPT-3E

677C453G09

LCT -3E-<=>15CLPT-3E fuse private labelled for Littelfuse —

—

—

7184A65G15

15CLPT-5E

677C452G03

LCT -5E-<=>15CLPT-5E fuse private labelled for Littelfuse —

—

—

7184A65G16

15CLPT-10E

677C452G06

LCT -10E-<=>15CLPT-10E fuse private labelled for
Littelfuse

—

—

—

7184A65G17

25CLPT-.5E

677C452G03

LCJ -1/2E-<=>25CLPT-.5E fuse private labelled for
Littelfuse

—

—

—

7184A65G18

25CLPT-1E

677C452G08

LCJ -1E-<=>25CLPT-1E fuse private labelled for Littelfuse —

—

—

7184A66G01

2CLS-2R

591C812G02

LCK -2R-<=>2CLS-2R fuse private labelled for Littelfuse

—

—

—

7184A66G02

2CLS-3R

591C812G03

LCK -3R-<=>2CLS-3R fuse private labelled for Littelfuse

—

—

—

7184A66G03

2CLS-4R

591C812G04

LCK -4R-<=>2CLS-4R fuse private labelled for Littelfuse

—

—

—

7184A66G04

5ACLS-2R

449D597G02

LCL -2R-1-<=>5ACLS-2R fuse private labelled for
Littelfuse

—

—

—

7184A66G05

5ACLS-3R

449D597G03

LCL -3R-1-<=>5ACLS-3R fuse private labelled for
Littelfuse

—

—

—

7184A66G06

5ACLS-4R

449D597G04

LCL -4R-1-<=>5ACLS-4R fuse private labelled for
Littelfuse

—

—

—

7184A66G07

5ACLS-5R

449D597G05

LCL -5R-1-<=>5ACLS-5R fuse private labelled for
Littelfuse

—

—

—

7184A66G08

5ACLS-6R

449D597G06

LCL -6R-1-<=>5ACLS-6R fuse private labelled for
Littelfuse

—

—

—

7184A66G09

5ACLS-9R

151D933G01

LCL -9R-1-<=>5ACLS-9R fuse private labelled for
Littelfuse

—

—

—

7184A66G10

5ACLS-12R

151D933G02

LCL -12R-1-<=>5ACLS-12R fuse private labelled for
Littelfuse

—

—

—

7184A66G11

5ACLS-18R

151D933G03

LCL -18R-1-<=>5ACLS-18R fuse private labelled for
Littelfuse

—

—

—

7184A66G12

5ACLS-24R

151D933G04

LCL -24R-1-<=>5ACLS-24R fuse private labelled for
Littelfuse

—

—

—

7184A66G13

5CLS70-36R

140D045G02

LCL -36R-1-<=>5CLS70-36R fuse private labelled for
Littelfuse

—

—

—

7184A66G14

2CLS-5R

591C812G05

LCK -5R-<=>2CLS-5R fuse private labelled for Littelfuse

—

—

—

7184A66G15

2CLS-6R

591C812G06

LCK -6R-<=>2CLS-6R fuse private labelled for Littelfuse

—

—

—

7184A66G16

2CLS-9R

591C812G07

LCK -9R-<=>2CLS-9R fuse private labelled for Littelfuse

—

—

—

7184A66G17

2CLS-12R

591C812G08

LCK -12R-<=>2CLS-12R fuse private labelled for Littelfuse —

—

—

7184A66G18

2CLS-18R

591C813G01

LCK -18R-<=>2CLS-18R fuse private labelled for Littelfuse —

—

—

7184A66G19

2CLS-24R

591C813G02

LCK -24R-<=>2CLS-24R fuse private labelled for Littelfuse —

—

—

7184A66G20

5CLS-2R

151D241G02

LCL-2R<=>5CLS-2R fuse private labelled for Littelfuse

—

—

—

7184A66G21

5CLS-3R

151D241G03

LCL-3R<=>5CLS-3R fuse private labelled for Littelfuse

—

—

—

7184A66G22

5CLS-4R

151D241G04

LC -4R<=>5CLS-4R fuse private labelled for Littelfuse

—

—

—

7184A66G23

5CLS-5R

151D241G05

LC -5R<=>5CLS-5R fuse private labelled for Littelfuse

—

—

—

7184A66G24

5CLS-6R

151D241G06

LCL-6R<=>5CLS-6R fuse private labelled for Littelfuse

—

—

—

7184A66G25

5CLS-9R

151D961G01

LCL-9R<=>5CLS-9R fuse private labelled for Littelfuse

—

—

—

7184A66G26

5CLS-12R

151D961G02

LCL-12R<=>5CLS-12R fuse private labelled for Littelfuse

—

—

—

7184A66G27

5CLS-18R

151D961G03

LCL-18R<=>5CLS-18R fuse private labelled for Littelfuse

—

—

—

7184A66G28

5CLS-24R

151D961G04

LCL-24R<=>5CLS-24R fuse private labelled for Littelfuse

—

—

—

7185A11G01

5HLE-30E

5981C28G03

LCY-30E<=>5HLE-30E fuse private labelled for Littelfuse

—

—

—

7185A11G02

5HLE-40E

5981C64G01

LCY-40E<=>5HLE-340E fuse private labelled for Littelfuse —

—

—

7185A11G03

5HLE-50E

5981C64G02

LCY-50E<=>5HLE-50E fuse private labelled for Littelfuse

—

—

—

7185A11G04

5HLE-250E

5981C64G10

LCY-250E<=>5HLE-250E fuse private labelled for
Littelfuse

—

—

—

7185A11G05

5HLE-300E

5981C66G01

LCY-300E<=>5HLE-300E fuse private labelled for
Littelfuse

—

—

—

7185A11G06

5HLE-450E

5981C66G04

LCY-450E<=>5HLE-450E fuse private labelled for
Littelfuse

—

—

—

7185A11G07

15HLE-20E

5981C32G03

LDN-20E<=>15HLE-20E fuse private labelled for Littelfuse —

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current
Rating
Amperes

V14-A2-101

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

7185A11G08

15HLE-25E

5981C32G04

LDN-25E<=>15HLE-25E fuse private labelled for Littelfuse —

—

—

7185A11G09

15HLE-30E

5981C32G05

LDN-30E<=>15HLE-30E fuse private labelled for Littelfuse —

—

—

7185A11G10

15HLE-40E

5981C18G04

LDN-40E<=>15HLE-40E fuse private labelled for Littelfuse —

—

—

7185A11G11

15HLE-50E

5981C18G05

LDN-50E<=>15HLE-50E fuse private labelled for Littelfuse —

—

—

7185A11G12

15HLE-65E

5981C18G06

LDN-65E<=>15HLE-65E fuse private labelled for Littelfuse —

—

—

7185A11G13

15HLE-80E

5981C18G07

LDN-80E<=>15HLE-80E fuse private labelled for Littelfuse —

—

—

7185A11G14

15HLE-100E

5981C18G08

LDN-100E<=>15HLE-100E fuse private labelled for
Littelfuse

—

—

—

7185A11G15

15HLE-150E

5981C44G01

LDN-150E<=>15HLE-150E fuse private labelled for
Littelfuse

—

—

—

7185A11G16

15HLE-175E

5981C44G02

LDN-175E<=>15HLE-175E fuse private labelled for
Littelfuse

—

—

—

7185A11G17

8HLE-25E

5981C30G04

LDZ-25E<=>8HLE-25E fuse private labelled for Littelfuse

—

—

—

7185A11G18

8HLE-30E

5981C30G05

LDZ-30E<=>8HLE-30E fuse private labelled for Littelfuse

—

—

—

7185A11G19

8HLE40E

5981C16G04

LDZ-40E<=>8HLE-40E fuse private labelled for Littelfuse

—

—

—

7185A11G20

8HLE-50E

5981C16G05

LDZ-50E<=>8HLE-50E fuse private labelled for Littelfuse

—

—

—

7185A11G21

8HLE-65E

5981C16G06

LDZ-65E<=>8HLE-65E fuse private labelled for Littelfuse

—

—

—

7185A11G22

8HLE-80E

5981C16G07

LDZ-80E<=>8HLE-80E fuse private labelled for Littelfuse

—

—

—

7185A11G23

8HLE-100E

5981C16G08

LDZ-100E<=>8HLE-100E fuse private labelled for
Littelfuse

—

—

—

7185A11G24

8HLE-125E

5981C16G09

LDZ-125E<=>8HLE-125E fuse private labelled for
Littelfuse

—

—

—

7185A11G25

8HLE-150E

5981C16G10

LDZ-150E<=>8HLE-30E fuse private labelled for Littelfuse —

—

—

7185A11G26

8HLE-175E

5981C16G11

LDZ-175E<=>8HLE-175E fuse private labelled for
Littelfuse

—

—

—

7185A11G27

8HLE-200E

5981C22G01

LDZ-200E<=>8HLE-200E fuse private labelled for
Littelfuse

—

—

—

7185A11G28

8HLE-250E

5981C22G02

LDZ-250E<=>8HLE-250E fuse private labelled for
Littelfuse

—

—

—

7185A11G29

8HLE-300E

5981C22G03

LDZ-300E<=>8HLE-300E fuse private labelled for
Littelfuse

—

—

—

7185A11G30

8HLE-350E

5981C22G04

LDZ-350E<=>8HLE-350E fuse private labelled for
Littelfuse

—

—

—

7185A11G31

8HLE-20E

5981C30G03

LDZ-20E<=>8HLE-20E fuse private labelled for Littelfuse

—

—

—

7185A11G32

8CLE-15E

678C248G07

LCZ-15E<=>8CLE-15E fuse private labelled for Littelfuse

—

—

—

7185A11G33

8CLE-25E

678C248G09

LCZ-25E<=>8CLE-25E fuse private labelled for Littelfuse

—

—

—

7185A11G34

8CLE-30E

5981C32G05

LCZ-30E<=>8CLE-30E fuse private labelled for Littelfuse

—

—

—

7185A11G35

8CLE-40E

5981C17G04

LCZ-40E<=>8CLE-40E fuse private labelled for Littelfuse

—

—

—

7185A11G36

8CLE-50E

5981C17G05

LCZ-50E<=>8CLE-50E fuse private labelled for Littelfuse

—

—

—

7185A11G37

8CLE-65E

5981C17G06

LCZ-65E<=>8CLE-65E fuse private labelled for Littelfuse

—

—

—

7185A11G38

8CLE-80E

5981C17G07

LCZ-80E<=>8CLE-80E fuse private labelled for Littelfuse

—

—

—

7185A11G39

8CLE-100E

5981C17G08

LCZ-100E<=>8CLE-100E fuse private labelled for Littelfuse —

—

—

7185A11G40

8CLE-125E

5981C17G09

LCZ-125E<=>8CLE-125E fuse private labelled for Littelfuse —

—

—

7185A11G41

8CLE-150E

5981C17G10

LCZ-150E<=>8CLE-150E fuse private labelled for Littelfuse —

—

—

7185A11G42

8CLE-200E

5981C23G01

LCZ-200E<=>8CLE-200E fuse private labelled for Littelfuse —

—

—

7185A43G01

5HLE-10E

5981C28G01

LCY-10E <=> 5HLE-10E-N fuse private labelled for
Littelfuse

—

—

—

7185A43G02

5HLE-15E

5981C28G02

LCY-15E <=> 5HLE-15E-N fuse private labelled for
Littelfuse

—

—

—

7185A43G03

5HLE-20E

5981C28G03

LCY-20E <=> 5HLE-20E-N fuse private labelled for
Littelfuse

—

—

—

7185A43G04

5HLE-25E

5981C28G04

LCY-25E <=> 5HLE-25E-N fuse private labelled for
Littelfuse

—

—

—

7185A43G05

5HLE-30E

5981C28G05

LCY-30E <=> 5HLE-30E-N fuse private labelled for
Littelfuse

—

—

—

7185A43G06

5HLE-40E

5981C65G01

LCY-40E <=> 5HLE-40E-N fuse private labelled for
Littelfuse

—

—

—

V14-A2-102

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

7185A43G07

5HLE-50E

7185A43G08

5981C65G02

LCY-50E <=> 5HLE-50E-N fuse private labelled for
Littelfuse

—

—

—

5HLE-65E

5981C65G03

LCY-65E <=> 5HLE-65E-N fuse private labelled for
Littelfuse

—

—

—

7185A43G09

5HLE-80E

5981C65G04

LCY-80E <=> 5HLE-80E-N fuse private labelled for
Littelfuse

—

—

—

7185A43G10

5HLE-100E

5981C65G05

LCY-100E <=> 5HLE-100E-N fuse private labelled for
Littelfuse

—

—

—

7185A44G01

8HLE-10E

5981C30G01

LDZ-10E <=> 8HLE-10E-N fuse private labelled for
Littelfuse

—

—

—

7185A44G02

8HLE-15E

5981C30G02

LDZ-15E <=> 8HLE-15E-N fuse private labelled for
Littelfuse

—

—

—

7185A44G03

8HLE-20E

5981C30G03

LDZ-20E <=> 8HLE-20E-N fuse private labelled for
Littelfuse

—

—

—

7185A44G04

8HLE-25E

5981C30G04

LDZ-25E <=> 8HLE-25E-N fuse private labelled for
Littelfuse

—

—

—

7185A44G05

8HLE-30E

5981C30G05

LDZ-30E <=> 8HLE-30E-N fuse private labelled for
Littelfuse

—

—

—

7185A44G06

8HLE-40E

5981C16G01

LDZ-40E <=> 8HLE-40E-N fuse private labelled for
Littelfuse

—

—

—

7185A44G07

8HLE-50E

5981C16G02

LDZ-50E <=> 8HLE-50E-N fuse private labelled for
Littelfuse

—

—

—

7185A44G08

8HLE-65E

5981C16G03

LDZ-65E <=> 8HLE-65E-N fuse private labelled for
Littelfuse

—

—

—

7185A44G09

8HLE-80E

5981C16G04

LDZ-80E <=> 8HLE-80E-N fuse private labelled for
Littelfuse

—

—

—

7185A44G10

8HLE-100E

5981C16G05

LDZ-100E <=> 8HLE-100E-N fuse private labelled for
Littelfuse

—

—

—

7185A45G01

15HLE-10E

5981C32G01

LDN-10E <=> 15HLE-10E-N fuse private labelled for
Littelfuse

—

—

—

7185A45G02

15HLE-15E

5981C32G02

LDN-15E <=> 15HLE-15E-N fuse private labelled for
Littelfuse

—

—

—

7185A45G03

15HLE-20E

5981C32G03

LDN-20E <=> 15HLE-20E-N fuse private labelled for
Littelfuse

—

—

—

7185A45G04

15HLE-25E

5981C32G04

LDN-25E <=> 15HLE-25E-N fuse private labelled for
Littelfuse

—

—

—

7185A45G05

15HLE-30E

5981C32G05

LDN-30E <=> 15HLE-30E-N fuse private labelled for
Littelfuse

—

—

—

7185A45G06

15HLE-40E

5981C18G01

LDN-40E <=> 15HLE-40E-N fuse private labelled for
Littelfuse

—

—

—

7185A45G07

15HLE-50E

5981C18G02

LDN-50E <=> 15HLE-50E-N fuse private labelled for
Littelfuse

—

—

—

7185A45G08

15HLE-65E

5981C18G03

LDN-65E <=> 15HLE-65E-N fuse private labelled for
Littelfuse

—

—

—

7185A45G09

15HLE-80E

5981C18G04

LDN-80E <=> 15HLE-80E-N fuse private labelled for
Littelfuse

—

—

—

7185A45G10

15HLE-100E

5981C18G05

LDN-100E <=> 15HLE-100E-N fuse private labelled for
Littelfuse

—

—

—

7185A48G01

5CLE-10E-D

5981C29G01

LCU-10E<=>5CLE-10E-D fuse private labelled for
Littelfuse

—

—

—

7185A48G02

5CLE-15E

678C240G04

LCU-15E<=>5CLE-15E fuse private labelled for Littelfuse

—

—

—

7185A48G03

5CLE-20E

678C240G05

LCU-20E<=>5CLE-20E fuse private labelled for Littelfuse

—

—

—

7185A48G04

5CLE-25E

678C240G06

LCU-25E<=>5CLE-25E fuse private labelled for Littelfuse

—

—

—

7185A48G05

5CLE-40E

5981C65G01

LCU-40E<=>5CLE-40E fuse private labelled for Littelfuse

—

—

—

7185A48G06

5CLE-125E

5981C65G06

LCU-125E<=>5CLE-125E fuse private labelled for
Littelfuse

—

—

—

7185A48G07

15CLE-15E

678C240G10

LCN-15E<=>15CLE-15E fuse private labelled for Littelfuse —

—

—

7185A48G08

15CLE-20E

678C240G11

LCN-20E<=>15CLE-20E fuse private labelled for Littelfuse —

—

—

7185A48G09

15CLE-25E

678C240G12

LCN-25E<=>15CLE-25E fuse private labelled for Littelfuse —

—

—

7185A48G10

15CLE-80E

5981C19G07

LCN-80ES<=>15CLE-80E fuse private labelled for
Littelfuse

—

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current
Rating
Amperes

V14-A2-103

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

7185A48G11

15CLE-100E

7185A48G12

5981C19G08

LCN-100ES<=>15CLE-100E fuse private labelled for
Littelfuse

—

—

—

15CLE-125E

5981C19G09

LCN-125ES<=>15CLE-125E fuse private labelled for
Littelfuse

—

—

—

7185A48G13

15CLE-150E

5981C19G10

LCN-150ES<=>15CLE-150E fuse private labelled for
Littelfuse

—

—

—

7185A48G14

15CLE-175E

5982C25G01

LCN-175ED<=>15CLE-175E fuse private labelled for
Littelfuse

—

—

—

7185A48G15

15CLE-200E

5982C25G02

LCN-200ED<=>15CLE-200E fuse private labelled for
Littelfuse

—

—

—

7185A48G16

15CLE-250E

5982C25G03

LCN-250ED<=>15CLE-250E fuse private labelled for
Littelfuse

—

—

—

7185A48G17

15CLE-300E

5982C25G04

LCN-300ED<=>15CLE-300E fuse private labelled for
Littelfuse

—

—

—

7185A48G18

5CLE-175E

5981C65G08

LCU-175E<=>5CLE-175E fuse private labelled for
Littelfuse

—

—

—

7185A48G19

5CLE-250E

5981C65G10

LCU-250ES<=>5CLE-250E fuse private labelled for
Littelfuse

—

—

—

7185A48G20

5CLE-350X

5981C67G02

LCU-350X<=>5CLE-350E fuse private labelled for
Littelfuse

—

—

—

7185A48G21

Obsolete—contact Eaton

—

—

—

—

—

7185A48G22

5CLE-450E

5981C67G04

LCU-450X<=>5CLE-450E fuse private labelled for
Littelfuse

—

—

—

7185A48G23

Obsolete—contact Eaton

—

—

—

—

—

7185A48G24

Obsolete—contact Eaton

—

—

—

—

—

7185A48G25

8CLE-175E

5981C17G11

LCZ-175E <=> 8CLE-175E fuse private labelled for
Littelfuse

—

—

—

7185A48G26

5CL5-350E

5981C67G02

LCU-350E <=> 5CLE-350E fuse private labelled for
Littelfuse

—

—

—

7185A48G27

5HLE-175E

5981C64G08

LCY-175E <=>5CLE-175E fuse private labelled for
Littelfuse

—

—

—

7185A48G28

5HLE-350E

5981C66G02

LCY-350E <=> 5CLE-350E fuse private labelled for
Littelfuse

—

—

—

7185A40G01

5HLE-10E

5981C28G01

—

HLE

5.5

10E

7185A40G02

5HLE-15E

5981C28G02

—

HLE

5.5

15E

7185A40G03

5HLE-20E

5981C28G03

—

HLE

5.5

20E

7185A40G04

5HLE-25E

5981C28G04

—

HLE

5.5

25E

7185A40G05

5HLE-30E

5981C28G05

—

HLE

5.5

30E

7185A40G06

5HLE-40E

5981C64G01

—

HLE

5.5

40E

7185A40G07

5HLE-50E

5981C64G02

—

HLE

5.5

50E

7185A40G08

5HLE-65E

5981C64G03

—

HLE

5.5

65E

7185A40G09

5HLE-80E

5981C64G04

—

HLE

5.5

80E

7185A40G10

5HLE-100E

5981C64G05

—

HLE

5.5

100E

7185A40G11

5AHLE-10E

5981C64G01

—

HLE

5.5

10E

7185A40G12

5AHLE-15E

5981C64G02

—

HLE

5.5

15E

7185A40G13

5AHLE-20E

5981C64G03

—

HLE

5.5

20E

7185A40G14

5AHLE-25E

5981C64G04

—

HLE

5.5

25E

7185A40G15

5AHLE-30E

5981C64G05

—

HLE

5.5

30E

7185A40G16

5AHLE-40E

5981C64G06

—

HLE

5.5

40E

7185A40G17

5AHLE-50E

5981C64G07

—

HLE

5.5

50E

7185A40G18

5AHLE-65E

5981C64G08

—

HLE

5.5

65E

7185A40G19

5AHLE-80E

5981C64G09

—

HLE

5.5

80E

7185A40G20

5AHLE-100E

5981C64G10

—

HLE

5.5

100E

7185A41G01

8HLE-10E

5981C30G01

—

HLE

8.3

10E

7185A41G02

8HLE-15E

5981C30G02

—

HLE

8.3

15E

7185A41G03

8HLE-20E

5981C30G03

—

HLE

8.3

20E

7185A41G04

8HLE-25E

5981C30G04

—

HLE

8.3

25E

7185A41G05

8HLE-30E

5981C30G05

—

HLE

8.3

30E

V14-A2-104

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current
Rating
Amperes

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

7185A41G06

8HLE-40E

5981C16G04

7185A41G07

8HLE-50E

5981C16G05

—

HLE

8.3

40E

—

HLE

8.3

7185A41G08

8HLE-65E

50E

5981C16G06

—

HLE

8.3

7185A41G09

65E

8HLE-80E

5981C16G07

—

HLE

8.3

80E

7185A41G10

8HLE-100E

5981C16G08

—

HLE

8.3

100E

7185A41G11

8AHLE-10E

5981C47G01

—

HLE

8.3

10E

7185A41G12

8AHLE-15E

5981C47G02

—

HLE

8.3

15E

7185A41G13

8AHLE-20E

5981C47G03

—

HLE

8.3

20E

7185A41G14

8AHLE-25E

5981C47G04

—

HLE

8.3

25E

7185A41G15

8AHLE-30E

5981C47G05

—

HLE

8.3

30E

7185A41G16

8AHLE-40E

5981C47G06

—

HLE

8.3

40E

7185A41G17

8AHLE-50E

5981C47G07

—

HLE

8.3

50E

7185A41G18

8AHLE-65E

5981C47G08

—

HLE

8.3

65E

7185A41G19

8AHLE-80E

5981C47G09

—

HLE

8.3

80E

7185A41G20

8AHLE-100E

5981C47G10

—

HLE

8.3

100E

7185A42G01

15HLE-10E

5981C32G01

—

HLE

15.5

10E

7185A42G02

15HLE-15E

5981C32G02

—

HLE

15.5

15E

7185A42G03

15HLE-20E

5981C32G03

—

HLE

15.5

20E

7185A42G04

15HLE-25E

5981C32G04

—

HLE

15.5

25E

7185A42G05

15HLE-30E

5981C32G05

—

HLE

15.5

30E

7185A42G06

15HLE-40E

5981C18G04

—

HLE

15.5

40E

7185A42G07

15HLE-50E

5981C18G05

—

HLE

15.5

50E

7185A42G08

15HLE-65E

5981C18G06

—

HLE

15.5

65E

7185A42G09

15HLE-80E

5981C18G07

—

HLE

15.5

80E

7185A42G10

15HLE-100E

5981C18G08

—

HLE

15.5

100E

7186A29G01

5NCLPT-.5E

7186A29G01

—

CLPT

5.5

.5E

7186A29G02

5NCLPT-1E

7186A29G02

—

CLPT

5.5

1E

7186A29G03

5NCLPT-2E

7186A29G03

—

CLPT

5.5

2E

7186A29G04

5NCLPT-3E

7186A29G04

—

CLPT

5.5

3E

7186A29G05

5NCLPT-4E

7186A29G05

—

CLPT

5.5

4E

7186A29G06

5NCLPT-5E

7186A29G06

—

CLPT

5.5

5E

7186A29G11

317A487H02

7186A29G11

—

CLPT

5.5

.5E

7186A29G12

317A487H06

7186A29G12

—

CLPT

5.5

1E

7186A29G13

317A487H03

7186A29G13

—

CLPT

5.5

2E

7186A29G14

317A487H04

7186A29G14

—

CLPT

5.5

3E

7186A29G15

317A487H05

7186A29G15

—

CLPT

5.5

5E

7187A11G01

DBU-EFID

7187A11G04

—

DBU

—

200

7187A11G02

DBU-EFOD

7187A11G02

—

DBU

—

200

7187A11G03

DBU-EFID

7187A11G04

—

DBU

—

200

7187A11G04

DBU-EFID

7187A11G04

—

DBU

—

200

722C373A02

2CLE-30E

449D797G02

—

CLE

2.75

30E

722C373A04

2CLE-50E

449D797G03

—

CLE

2.75

50E

722C373A05

2CLE-65E

449D797G04

—

CLE

2.75

65E

722C373A06

2CLE-80E

449D797G05

—

CLE

2.75

80E

722C373A07

2CLE-100E

449D797G06

—

CLE

2.75

100E

722C373A08

2CLE-125E

449D797G07

—

CLE

2.75

125E

722C373A09

2CLE-150E

449D797G08

—

CLE

2.75

150E

722C373A10

2CLE-200E

449D797G09

—

CLE

2.75

200E

726C972A02

5CLE-30E

5981C29G05

—

CLE

5.5

30E

726C972A04

5CLE-50E

5981C65G02

—

CLE

5.5

50E

726C972A05

5CLE-65E

5981C65G03

—

CLE

5.5

65E

726C972A06

5CLE-80E

5981C65G04

—

CLE

5.5

80E

726C972A07

5CLE100E

5981C65G05

—

CLE

5.5

100E

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-105

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

726C972A08

5CLE-125E

5981C65G06

726C972A09

5CLE-150E

5981C65G07

—

CLE

5.5

125E

—

CLE

5.5

726C972A10

5CLE-200E

150E

5981C65G09

—

CLE

5.5

726C973A01

200E

8CLE-30E

5981C31G05

—

CLE

8.3

30E

726C973A02

8CLE-40E

5981C17G04

—

CLE

8.3

40E

726C973A03

8CLE-50E

5981C17G05

—

CLE

8.3

50E

726C973A04

8CLE-65E

5981C17G06

—

CLE

8.3

65E

726C973A05

8CLE-80E

5981C17G07

—

CLE

8.3

80E

726C973A06

8CLE-100E

5981C17G08

—

CLE

8.3

100E

726C974A02

15CLE-30E

5981C33G05

—

CLE

15.5

30E

726C974A03

15CLE-40E

5981C19G04

—

CLE

15.5

40E

726C974A04

15CLE-50E

5981C19G05

—

CLE

15.5

50E

726C974A05

15CLE-65E

5981C19G06

—

CLE

15.5

65E

726C974A06

15CLE-80E

5981C19G07

—

CLE

15.5

80E

726C974A07

15CLE-100E

5981C19G08

—

CLE

15.5

100E

7275A85G02

CXN-CLMP

7275A85G02

—

CXN

—

—

7276A67G01

15RBA2-DL

9078A26A01

—

RBA2

—

200

7276A67G02

15RBA4-DL

9078A20A01

—

RBA2

—

200

7276A67G03

38RBA2-DL

9078A26A02

—

RBA4

—

400

7276A67G04

38RBA4-DL

9078A20A02

—

RBA4

—

300

758C433A21

15CLPT-.5E

677C452G03

—

CLPT

15.5

0.5

758C433A39

2CLE-15E

678C240G01

—

CLE

2.75

15E

758C433A40

2CLE-20E

678C240G02

—

CLE

2.75

20E

758C433A41

2CLE-25E

678C240G03

—

CLE

2.75

25E

758C433A42

5CLE-15E

678C240G04

—

CLE

5.5

15E

758C433A43

5CLE-20E

678C240G05

—

CLE

5.5

20E

758C433A44

5CLE-25E

678C240G06

—

CLE

5.5

25E

758C433A45

8CLE-15E

678C240G07

—

CLE

8.3

15E

758C433A46

8CLE-20E

678C240G08

—

CLE

8.3

20E

758C433A47

8CLE-25E

678C240G09

—

CLE

8.3

25E

758C433A48

15CLE-15E

678C240G10

—

CLE

15.5

15E

758C433A49

15CLE-20E

678C240G11

—

CLE

15.5

20E

758C433A50

15CLE-25E

678C240G12

—

CLE

15.5

25E

853C830G02

2NCLPT-1E

677C592G03

—

CLPT

2.75

1

853C830G03

2NCLPT-.5E

677C592G02

—

CLPT

2.75

0.5

853C830G07

5NCLPT-.5E

677C592G06

—

CLPT

5.5

0.5

853C832G01

Obsolete—contact Eaton

—

6CLV-2E

—

—

—

853C832G02

Obsolete—contact Eaton

—

6CLV-5E

—

—

—

853C832G03

Obsolete—contact Eaton

—

6CLV-7E

—

—

—

853C832G04

Obsolete—contact Eaton

—

6CLV-10E

—

—

—

9078A19G01

5RBA4-PDM

9078A19G01

—

RBA4

5.5

400

9078A19G02

5RBA4-GDM

9078A19G02

—

RBA4

5.5

400

9078A19G03

14RBA4-PDM

9078A19G03

—

RBA4

15.5

400

9078A19G04

14RBA4-GDM

9078A19G04

—

RBA4

15.5

400

9078A19G05

15RBA4-PDM

9078A19G05

—

RBA4

15.5

400

9078A19G06

25RBA4-PDM

9078A19G06

—

RBA4

25.5

300

9078A19G07

38RBA4-PDM

9078A19G07

—

RBA4

38

300

9078A19G08

8RBA4-PDM

9078A19G08

—

RBA4

8.3

400

9078A19G09

8RBA4-GDM

9078A19G09

—

RBA4

8.3

400

9078A20A01

15RBA4-DL

9078A20A01

—

RBA4

15.5

400

9078A20A02

38RBA4-DL

9078A20A02

—

RBA4

38

300

9078A20A03

15RBA4-LBDL

9078A20A03

—

RBA4

15.5

400

9078A25G01

5RBA2-PDM

9078A25G01

—

RBA2

5.5

200

V14-A2-106

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

9078A25G02

5RBA2-GDM

9078A25G02

—

RBA2

5.5

200

9078A25G03

14RBA2-PDM

9078A25G03

—

RBA2

15.5

200

9078A25G04

14RBA2-GDM

9078A25G04

—

RBA2

15.5

200

9078A25G05

15RBA2-PDM

9078A25G05

—

RBA2

15.5

200

9078A25G06

25RBA2-PDM

9078A25G06

—

RBA2

25.5

200

9078A25G07

38RBA2-PDM

9078A25G07

—

RBA2

38

200

9078A25G08

8RBA2-PDM

9078A25G08

—

RBA2

8.3

200

9078A25G09

8RBA2-GDM

9078A25G09

—

RBA2

8.3

200

9078A26A01

15RBA2-DL

9078A26A01

—

RBA2

15.5

200

9078A26A02

38RBA2-DL

9078A26A02

—

RBA2

38

200

9078A26A03

15RBA2-LBDL

9078A26A03

—

RBA2

15.5

200

9078A30A01

38RBA2-NL

9078A30A01

—

RBA2

38

200

9078A30A02

15RBA2-NL

9078A30A02

—

RBA2

15.5

200

9078A30A03

38RBA4-NL

9078A30A03

—

RBA4

38

300

9078A30A04

15RBA4-NL

9078A30A04

—

RBA4

15.5

400

9078A30A05

38RBA8-NL

9078A30A05

—

RBA8

38

540

9078A30A06

15RBA8-NL

9078A30A06

—

RBA8

15.5

720

9078A33G01

5RBA2-PNM

9078A33G01

—

RBA2

5.5

200

9078A33G02

8RBA2-PNM

9078A33G02

—

RBA2

8.3

200

9078A33G03

14RBA2-PNM

9078A33G03

—

RBA2

15.5

200

9078A33G04

25RBA2-PNM

9078A33G04

—

RBA2

25.5

200

9078A33G05

38RBA2-PNM

9078A33G05

—

RBA2

38

200

9078A33G06

5RBA4-PNM

9078A33G06

—

RBA4

5.5

400

9078A33G07

8RBA4-PNM

9078A33G07

—

RBA4

8.3

400

9078A33G08

14RBA4-PNM

9078A33G08

—

RBA4

15.5

400

9078A33G09

25RBA4-GNM

9078A33G09

—

RBA4

25.5

300

9078A33G10

38RBA4-GNM

9078A33G10

—

RBA4

38

300

9078A33G11

5RBA8-PNM

9078A33G11

—

RBA8

5.5

720

9078A33G12

8RBA8-PNM

9078A33G12

—

RBA8

8.3

720

9078A33G13

14RBA8-PNM

9078A33G13

—

RBA8

15.5

720

9078A33G14

25RBA8-GNM

9078A33G14

—

RBA8

25.5

540

9078A33G15

38RBA8-GNM

9078A33G15

—

RBA8

38

540

9078A33G16

5RBA2-GNM

9078A33G16

—

RBA2

5.5

200

9078A33G17

8RBA2-GNM

9078A33G17

—

RBA2

8.3

200

9078A33G18

14RBA2-GNM

9078A33G18

—

RBA2

15.5

200

9078A33G19

5RBA4-GNM

9078A33G19

—

RBA4

5.5

400

9078A33G20

8RBA4-GNM

9078A33G20

—

RBA4

8.3

400

9078A33G21

14RBA4-GNM

9078A33G21

—

RBA4

15.5

400

9078A33G22

5RBA8-GNM

9078A33G22

—

RBA8

5.5

720

9078A33G23

8RBA8-GNM

9078A33G23

—

RBA8

8.3

720

9078A33G24

14RBA8-GNM

9078A33G24

—

RBA8

15.5

720

9078A33G25

15RBA2-PNM

9078A33G25

—

RBA2

15.5

200

9078A33G26

15RBA4-PNM

9078A33G26

—

RBA4

15.5

400

9078A33G27

15RBA8-PNM

9078A33G27

—

RBA8

15.5

720

9078A63G01

CLPT-DF

9078A63G01

—

CLPT

—

10

9078A63G02

CLE-DF-C

9078A63G02

—

CLE

—

25

9078A63G03

CLE-DF-D

9078A63G03

—

CLE

—

250

9078A63G04

CLE-DF-E

9078A63G04

—

CLE

—

450

9078A64G01

CLPT-DL

9078A64G01

—

CLPT

—

10

9078A64G02

CLE-DL-C

9078A64G02

—

CLE

—

25

9078A64G03

CLE-DL-D

9078A64G03

—

CLE

—

250

9078A64G04

CLE-DL-E

9078A64G04

—

CLE

—

450

9078A64G12

9078A64G12

9078A64G12

Special mounting for triple barrel 15CLE3 fuse

CLE

—

200

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Current
Rating
Amperes

V14-A2-107

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

9078A64G14

25CLPT-DL

9078A64G14

9078A65G01

5CLPT-PDM-A

9078A65G01

—

CLPT

25.5

1

—

CLPT

5.5

9078A65G02

8CLPT-PDM-A

10

9078A65G02

—

CLPT

8.3

9078A65G03

10

15CLPT-PDM-A

9078A65G03

—

CLPT

15.5

10

9078A65G04

15CLPT-HPDM-A

9078A65G04

—

CLPT

15.5

10

9078A65G05

25CLPT-HPDM-A

9078A65G05

—

CLPT

25.5

1

9078A65G06

5CLPT-PDM-A

9078A65G06

—

CLPT

5.5

10

9078A65G07

8CLPT-PDM-B

9078A65G07

—

CLPT

8.3

10

9078A65G08

15CLPT-PDM-B

9078A65G08

—

CLPT

15.5

10

9078A65G09

15CLPT-HPDM-B

9078A65G09

—

CLPT

15.5

10

9078A65G10

2CLE-PDM-C

9078A65G10

—

CLE

2.75

25

9078A65G11

5CLE-PDM-C

9078A65G11

—

CLE

5.5

25

9078A65G12

8CLE-PDM-C

9078A65G12

—

CLE

8.3

25

9078A65G13

15CLE-PDM-C

9078A65G13

—

CLE

15.5

25

9078A65G14

15CLE-HPDM-C

9078A65G14

—

CLE

15.5

25

9078A65G15

2CLE-PDM-D

9078A65G15

—

CLE

2.75

250

9078A65G16

5CLE-PDM-D

9078A65G16

—

CLE

5.5

250

9078A65G17

8CLE-PDM-D

9078A65G17

—

CLE

8.3

175

9078A65G18

15CLE-PDM-D

9078A65G18

—

CLE

15.5

150

9078A65G19

15CLE-HPDM-D

9078A65G19

—

CLE

15.5

150

9078A65G20

2CLE-PDM-E

9078A65G20

—

CLE

2.75

450

9078A65G21

5CLE-PDM-E

9078A65G21

—

CLE

5.5

450

9078A65G22

8CLE-PDM-E

9078A65G22

—

CLE

8.3

350

9078A65G23

15CLE-PDM-E

9078A65G23

—

CLE

15.5

300

9078A65G24

5CLPT-GDM-A

9078A65G24

—

CLPT

5.5

10

9078A65G25

8CLPT-GDM-A

9078A65G25

—

CLPT

8.3

2

9078A65G26

15CLPT-GDM-A

9078A65G26

—

CLPT

15.5

2

9078A65G27

5CLPT-GDM-A

9078A65G27

—

CLPT

5.5

10

9078A65G28

8CLPT-GDM-B

9078A65G28

—

CLPT

8.3

10

9078A65G29

15CLPT-GDM-B

9078A65G29

—

CLPT

15.5

10

9078A65G30

2CLE-GDM-C

9078A65G30

—

CLE

2.75

25

9078A65G31

5CLE-GDM-C

9078A65G31

—

CLE

5.5

25

9078A65G32

8CLE-GDM-C

9078A65G32

—

CLE

8.3

25

9078A65G33

15CLE-GDM-C

9078A65G33

—

CLE

15.5

25

9078A65G34

2CLE-GDM-D

9078A65G34

—

CLE

2.75

250

9078A65G35

5CLE-GDM-D

9078A65G35

—

CLE

5.5

250

9078A65G36

8CLE-GDM-D

9078A65G36

—

CLE

8.3

175

9078A65G37

15CLE-GDM-D

9078A65G37

—

CLE

15.5

150

9078A65G38

2CLE-GDM-E

9078A65G38

—

CLE

2.75

450

9078A65G39

5CLE-GDM-E

9078A65G39

—

CLE

5.5

450

9078A65G40

8CLE-GDM-E

9078A65G40

—

CLE

8.3

350

9078A67G01

CLPT-NL

9078A67G01

—

CLPT

—

10

9078A67G02

CLE-NL-C

9078A67G02

—

CLE

—

25

9078A67G03

CLE-NL-D

9078A67G03

—

CLE

—

250

9078A67G04

CLE-NL-E

9078A67G04

—

CLE

—

450

9078A67G05

9078A67G05

9078A67G05

Special live parts for triple barrel 15CLE3 fuse

CLE

15.5

200

9078A67G12

25CLPT-NL

9078A67G12

—

CLPT

25.5

1

9078A67G15

CLE-NLC-E

9078A67G15

—

CLE

—

450

9078A67G16

CLPT-NLC

9078A67G16

—

CLE

—

25

9078A67G17

CLE-NLC-C

9078A67G17

—

CLE

—

25

9078A67G20

CLE-NLC-D

9078A67G20

—

CLE

—

250

9078A68G01

5CLPT-PNM-A

9078A68G01

—

CLPT

5.5

10

9078A68G02

8CLPT-PNM-A

9078A68G02

—

CLPT

8.3

1.5

V14-A2-108

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

9078A68G03

15CLPT-PNM-A

9078A68G03

9078A68G04

15CLPT-HPNM-A

9078A68G04

—

CLPT

15.5

1.5

—

CLPT

15.5

9078A68G05

25CLPT-HPNM-A

1.5

9078A68G05

—

CLPT

25.5

9078A68G06

1

5CLPT-PNM-A

9078A68G06

—

CLPT

—

—

9078A68G07

8CLPT-PNM-B

9078A68G07

—

CLPT

8.3

10

9078A68G08

15CLPT-PNM-B

9078A68G08

—

CLPT

15.5

10

9078A68G09

15CLPT-HPNM-B

9078A68G09

—

CLPT

15.5

10

9078A68G10

2CLE-PNM-C

9078A68G10

—

CLE

2.75

25

9078A68G11

5CLE-PNM-C

9078A68G11

—

CLE

5.5

25

9078A68G12

8CLE-PNM-C

9078A68G12

—

CLE

8.3

25

9078A68G13

15CLE-PNM-C

9078A68G13

—

CLE

15.5

25

9078A68G14

15CLE-HPNM-C

9078A68G14

—

CLE

15.5

25

9078A68G15

2CLE-PNM-D

9078A68G15

—

CLE

2.75

250

9078A68G16

5CLE-PNM-D

9078A68G16

—

CLE

5.5

250

9078A68G17

8CLE-PNM-D

9078A68G17

—

CLE

8.3

175

9078A68G18

15CLE-PNM-D

9078A68G18

—

CLE

15.5

150

9078A68G19

15CLE-HPNM-D

9078A68G19

—

CLE

15.5

150

9078A68G20

2CLE-PNM-E

9078A68G20

—

CLE

2.75

450

9078A68G21

5CLE-PNM-E

9078A68G21

—

CLE

5.5

450

9078A68G22

8CLE-PNM-E

9078A68G22

—

CLE

8.3

350

9078A68G23

15CLE-PNM-E

9078A68G23

—

CLE

15.5

300

9078A68G24

9078A68G24

9078A68G24

Special mounting for triple barrel 15CLE3 fuse

CLE

15.5

200

9078A68G25

5CLPT-GNM-A

9078A68G25

—

CLPT

5.5

10

9078A68G26

8CLPT-GNM-A

9078A68G26

—

CLPT

8.3

2

9078A68G27

15CLPT-GNM-A

9078A68G27

—

CLPT

15.5

2

9078A68G28

5CLPT-GNM-A

9078A68G28

—

—

—

—

9078A68G29

8CLPT-GNM-B

9078A68G29

—

CLPT

8.3

10

9078A68G30

15CLPT-GNM-B

9078A68G30

—

CLPT

15.5

10

9078A68G31

2CLE-GNM-C

9078A68G31

—

CLE

2.75

25

9078A68G32

5CLE-GNM-C

9078A68G32

—

CLE

5.5

25

9078A68G33

8CLE-GNM-C

9078A68G33

—

CLE

8.3

25

9078A68G34

15CLE-GNM-C

9078A68G34

—

CLE

15.5

25

9078A68G35

2CLE-GNM-D

9078A68G35

—

CLE

2.75

250

9078A68G36

5CLE-GNM-D

9078A68G36

—

CLE

5.5

250

9078A68G37

8CLE-GNM-D

9078A68G37

—

CLE

8.3

175

9078A68G38

15CLE-GNM-D

9078A68G38

—

CLE

15.5

150

9078A68G39

2CLE-GNM-E

9078A68G39

—

CLE

2.75

450

9078A68G40

5CLE-GNM-E

9078A68G40

—

CLE

5.5

450

9078A68G41

8CLE-GNM-E

9078A68G41

—

CLE

8.3

350

9078A68G42

25CLPT-PNM

9078A68G42

—

CLPT

25.5

1

9078A69G01

2CLE-PDM-D

9078A69G01

—

CLE

2.75

250

9078A69G02

5CLE-PDM-D

9078A69G02

—

CLE

5.5

250

9078A69G03

5CLS-HPDM-D

9078A69G03

—

CLS

5.08

230

9078A69G04

9078A69G04

9078A69G04

Heavy duty hinge and contacts

CLE

2.75

250

9078A69G05

9078A69G05

9078A69G05

Heavy duty hinge and contacts

CLE

5.5

250

9078A69G06

9078A69G06

9078A69G06

Heavy duty hinge and contacts

CLS

5.08

230

9078A69G07

2CLE-PDM-E

9078A69G07

—

CLE

2.75

450

9078A69G08

5CLE-PDM-E

9078A69G08

—

CLE

5.5

450

9078A69G09

5CLS-HPDM-E

9078A69G09

—

CLS

5.08

480

9078A69G10

2CLE-GDM-D

9078A69G10

—

CLE

2.75

250

9078A69G11

5CLE-GDM-D

9078A69G11

—

CLE

5.5

250

9078A69G12

5CLS-HGDM-D

9078A69G12

—

CLS

5.08

230

9078A69G13

9078A69G13

9078A69G13

Heavy duty hinge and contacts

CLE

2.75

250

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-109

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Description

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

9078A69G14

9078A69G14

9078A69G14

Heavy duty hinge and contacts

CLE

5.5

250

9078A69G15

9078A69G15

9078A69G15

Heavy duty hinge and contacts

CLS

5.08

230

9078A69G16

2CLE-GDM-E

9078A69G16

—

CLE

2.75

450

9078A69G17

5CLE-GDM-E

9078A69G17

—

CLE

5.5

450

9078A69G18

5CLS-HGDM-E

9078A69G18

—

CLS

5.08

480

9078A70G01

Obsolete—contact Eaton

—

Glass polyester insulator mounting for CLE-750E

—

—

—

9078A70G02

Obsolete—contact Eaton

—

Porcelain insulator mounting for CLE-750E

—

—

—

9570D04G01

Obsolete—contact Eaton

—

8CLTX-15K—comb. fuse and term.

—

—

—

9570D04G02

Obsolete—contact Eaton

—

8CLTX-15K—comb. fuse and term.

—

—

—

9570D04G03

Obsolete—contact Eaton

—

8CLTX-25K—comb. fuse and term.

—

—

—

9570D04G04

Obsolete—contact Eaton

—

8CLTX-25K—comb. fuse and term.

—

—

—

9570D04G05

Obsolete—contact Eaton

—

8CLTX-40K—comb. fuse and term.

—

—

—

9570D04G06

Obsolete—contact Eaton

—

8CLTX-40K—comb. fuse and term.

—

—

—

9570D04G11

Obsolete—contact Eaton

—

8CLTX-15K—comb. fuse and term.

—

—

—

9570D04G12

Obsolete—contact Eaton

—

8CLTX-15K—comb. fuse and term.

—

—

—

9570D04G16

Obsolete—contact Eaton

—

8CLTX-25K—comb. fuse and term.

—

—

—

9570D04G17

Obsolete—contact Eaton

—

8CLTX-25K—comb. fuse and term.

—

—

—

9570D04G21

Obsolete—contact Eaton

—

8CLTX-40K—comb. fuse and term.

—

—

—

9570D04G22

Obsolete—contact Eaton

—

8CLTX-40K—comb. fuse and term.

—

—

—

9570D04G36

Obsolete—contact Eaton

—

15CLTX-15K—comb. fuse and term.

—

—

—

9570D04G37

Obsolete—contact Eaton

—

15CLTX-15K—comb. fuse and term.

—

—

—

9570D04G38

Obsolete—contact Eaton

—

15CLTX-25K—comb. fuse and term.

—

—

—

9570D04G39

Obsolete—contact Eaton

—

15CLTX-25K—comb. fuse and term.

—

—

—

9570D04G40

Obsolete—contact Eaton

—

15CLTX-40K—comb. fuse and term.

—

—

—

9570D04G41

Obsolete—contact Eaton

—

15CLTX-40K—comb. fuse and term.

—

—

—

9570D04G51

Obsolete—contact Eaton

—

15CLTX-15K—comb. fuse and term.

—

—

—

9570D04G52

Obsolete—contact Eaton

—

15CLTX-15K—comb. fuse and term.

—

—

—

9570D04G56

Obsolete—contact Eaton

—

15CLTX-25K—comb. fuse and term.

—

—

—

9570D04G57

Obsolete—contact Eaton

—

15CLTX-25K—comb. fuse and term.

—

—

—

9570D04G61

Obsolete—contact Eaton

—

15CLTX-40K—comb. fuse and term.

—

—

—

9570D04G62

Obsolete—contact Eaton

—

15CLTX-40K—comb. fuse and term.

—

—

—

9570D04G76

Obsolete—contact Eaton

—

23CLTX-15K—comb. fuse and term.

—

—

—

9570D04G77

Obsolete—contact Eaton

—

23CLTX-15K—comb. fuse and term.

—

—

—

9570D04G83

Obsolete—contact Eaton

—

23CLTX-15K—comb. fuse and term.

—

—

—

9570D04G84

Obsolete—contact Eaton

—

23CLTX-15K—comb. fuse and term.

—

—

—

9570D05G02

15CXN-GNM-G

9570D05G02

—

CXN

15.5

—

9570D05G06

15CXN-NL-G

9570D05G06

—

CXN

15.5

—

9570D06G01

15CXN-GDM-G

9570D06G01

—

CXN

15.5

—

9570D06G03

15CXN-DL-G

9570D06G03

—

CXN

15.5

—

9570D06G05

15CXN-DF-G

9570D06G05

—

CXN

15.5

—

9570D10G01

15CLT-30

9570D10G01

—

CLT

15.5

30

9570D33G01

15CXN-GNM-F

9570D33G01

—

CXN

15.5

—

9570D33G02

15CXN--NL-F

9570D33G02

—

CXN

15.5

—

9570D33G03

15CXN-GNM-D

9570D33G03

—

CXN

15.5

—

9570D33G04

5CXN-NL-D

9570D33G04

—

CXN

15.5

—

9570D34G01

15CXN-GDM-F

9570D34G01

—

CXN

15.5

—

9570D34G02

15CXN-DL-F

9570D34G02

—

CXN

15.5

—

9570D56G01

Obsolete—contact Eaton

—

8CLTX-15K—spade-to-spade

—

—

—

9570D56G02

Obsolete—contact Eaton

—

8CLTX-15K—spade-to-stud

—

—

—

9570D56G03

Obsolete—contact Eaton

—

8CLTX-40K—spade-to-spade

—

—

—

9570D56G04

Obsolete—contact Eaton

—

8CLTX-40K—spade-to-stud

—

—

—

9570D56G05

Obsolete—contact Eaton

—

8CLTX-25K—spade-to-spade

—

—

—

9570D56G06

Obsolete—contact Eaton

—

8CLTX-25K—spade-to-stud

—

—

—

V14-A2-110

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 2—Superseded Style Number Index
Old
10 Digit
Style Number

Current Eaton
Catalog Number

Eaton
10 Digit
Style Number

Type

Voltage
Rating
kV Max.

Current
Rating
Amperes

Description

9570D56G09

Obsolete—contact Eaton

—

9570D56G10

Obsolete—contact Eaton

—

15CLTX-15K—spade-to-spade

—

—

—

15CLTX-15K—spade-to-stud

—

—

9570D56G11

Obsolete—contact Eaton

—

—

15CLTX-25K—spade-to-spade

—

—

9570D56G12

—

Obsolete—contact Eaton

—

15CLTX-25K—spade-to-stud

—

—

—

9570D56G13

Obsolete—contact Eaton

—

15CLTX-40K—spade-to-spade

—

—

—

9570D56G14

Obsolete—contact Eaton

—

15CLTX-40K—spade-to-stud

—

—

—

9570D56G15

Obsolete—contact Eaton

—

23CLTX-15K—spade-to-spade

—

—

—

9570D56G16

Obsolete—contact Eaton

—

23CLTX-15K—spade-to-stud

—

—

—

9570D64G01

5BCLS-32R

9570D64G01

—

—

—

—

9570D64G02

5BCLS-36R

9570D64G02

—

—

—

—

9570D64G03

5BCLS-44R

9570D64G03

—

—

—

—

9570D64G04

5BCLS-600E

9570D64G04

—

—

—

—

9570D64G05

5BCLS-750E

9570D64G05

—

—

—

—

9570D69G01

7BCLS-44R

9570D69G01

—

—

—

—

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A2-111

Appendix 3—Catalog Number/Style Number Cross Reference

Cross Reference
Catalog Number—Style Number Cross Reference
Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

121DBA2-100E

11A8127G53

14RBA8-GNM

9078A33G24

15BHLE-175E

5984C05G13

15CLE-PDM-D

9078A65G18

121DBA2-10E

11A8127G44

14RBA8-GNM

9078A33G24

15BHLE-200E

5984C05G14

15CLE-PDM-E

9078A65G23

121DBA2-125E

11A8127G54

14RBA8-PNM

9078A33G13

15BHLE-20E

5984C05G03

15CLE-PNM-C

9078A68G13

121DBA2-150E

11A8127G55

14RBA8-PNM

9078A33G13

15BHLE2-100E

5984C05G20

15CLE-PNM-D

9078A68G18

121DBA2-15E

11A8127G45

14RBA8-PNM

9078A33G13

15BHLE2-125E

5984C05G21

15CLE-PNM-E

9078A68G23

121DBA2-200E

11A8127G56

151D257G03

151D257G03

15BHLE2-40E

5984C05G16

15CLT-12C

678C295G02

121DBA2-20E

11A8127G46

151D257G04

151D257G04

15BHLE-250E

5984C05G15

15CLT-18C

678C295G07

121DBA2-25E

11A8127G47

15BA2-.5

117D123A17

15BHLE2-50E

5984C05G17

15CLT-30C

9570D10G01

121DBA2-3

11A8127G41

15BA2-100E

117D123A29

15BHLE-25E

5984C05G04

15CLT-4C

678C295G05

121DBA2-30E

11A8127G48

15BA2-10E

117D123A20

15BHLE2-65E

5984C05G18

15CLT-5C

678C295G04

121DBA2-40E

11A8127G49

15BA2-125E

117D123A30

15BHLE2-80E

5984C05G19

15CLT-8C

678C295G03

121DBA2-50E

11A8127G50

15BA2-150E

117D123A31

15BHLE-30E

5984C05G05

15CX-10C

151D883G11

121DBA2-5E

11A8127G42

15BA2-15E

117D123A21

15BHLE-40E

5984C05G06

15CX-12C

5980C19G07

121DBA2-65E

11A8127G51

15BA2-200E

117D123A32

15BHLE-50E

5984C05G07

15CX-15C

151D883G05

121DBA2-780E

11A8127G52

15BA2-20E

117D123A22

15BHLE-65E

5984C05G08

15CX-18C

5980C19G01

121DBA2-7E

11A8127G43

15BA2-25E

117D123A23

15BHLE-80E

5984C05G09

15CX-20C

5980C19G02

145DBA2-100E

11A8127G73

15BA2-30E

117D123A24

15CLE-100E

5981C19G08

15CX-25C

5980C19G03

145DBA2-10E

11A8127G64

15BA2-40E

117D123A25

15CLE-10E

5981C33G01

15CX-30C

5980C19G04

145DBA2-125E

11A8127G74

15BA2-50E

117D123A26

15CLE-125E

5981C19G09

15CX-3C

151D883G12

145DBA2-150E

11A8127G75

15BA2-5E

117D123A18

15CLE-150E

5981C19G10

15CX-40C

5980C19G05

145DBA2-15E

11A8127G65

15BA2-65E

117D123A27

15CLE-15E

678C240G10

15CX-4C

151D883G01

145DBA2-200E

11A8127G76

15BA2-7E

117D123A19

15CLE-15E-D

5981C33G02

15CX-6C

5980C19G06

145DBA2-20E

11A8127G66

15BA2-80E

117D123A28

15CLE-175E

5981C25G01

15CX-7C

151D883G02

145DBA2-25E

11A8127G67

15BA2-NH

310C198G02

15CLE-200E

5981C25G02

15CX-8C

5980C19G07

145DBA2-3

11A8127G61

15BA4-.5

116D977A21

15CLE-20E

678C240G11

15CX-GDM-G

151D885G03

145DBA2-30E

11A8127G68

15BA4-100E

116D977A33

15CLE-20E-D

5981C33G03

15CX-GNM-G

151D884G03

145DBA2-40E

11A8127G69

15BA4-10E

116D977A24

15CLE2-100E

439D482G05

15CXI-10C

151D883G31

145DBA2-50E

11A8127G70

15BA4-125E

116D977A34

15CLE2-125X

439D482G06

15CXI-12C

5980C19G27

145DBA2-5E

11A8127G62

15BA4-150E

116D977A35

15CLE-250E

5981C25G03

15CXI-15C

151D883G25

145DBA2-65E

11A8127G71

15BA4-15E

116D977A25

15CLE-25E

678C240G12

15CXI-18C

5980C19G21

145DBA2-780E

11A8127G72

15BA4-200E

116D977A36

15CLE-25E-D

5981C33G04

15CXI-20C

5980C19G22

145DBA2-7E

11A8127G63

15BA4-20E

116D977A26

15CLE2-80E

439D482G04

15CXI-25C

5980C19G23

14RBA2-GDM

9078A25G04

15BA4-250E

116D977A37

15CLE-300E

5981C25G04

15CXI-30C

5980C19G24

14RBA2-GDM

9078A25G04

15BA4-25E

116D977A27

15CLE-30E

5981C33G05

15CXI-3C

151D883g32

14RBA2-GNM

9078A33G18

15BA4-300E

116D977A38

15CLE3-150E

591C376G02

15CXI-40C

5980C19G25

14RBA2-GNM

9078A33G18

15BA4-30E

116D977A28

15CLE3-175E/200X

591C376G01

15CXI-4C

151D883G21

14RBA2-PDM

9078A25G03

15BA4-400E

116D977A39

15CLE-40E

5981C19G04

15CXI-6C

5980C19G26

14RBA2-PDM

9078A25G03

15BA4-40E

116D977A29

15CLE-50E

5981C19G05

15CXI-7C

151D883G22

14RBA2-PNM

9078A33G03

15BA4-50E

116D977A30

15CLE-65E

5981C19G06

15CXI-8C

5980C19G27

14RBA2-PNM

9078A33G03

15BA4-5E

116D977A22

15CLE-80E

5981C19G07

15CXN-100C

9570D02G06

14RBA4-GDM

9078A19G04

15BA4-65E

116D977A31

15CLE-GDM-C

9078A65G33

15CXN-45C

9570D02G02

14RBA4-GDM

9078A19G04

15BA4-7E

116D977A23

15CLE-GDM-D

9078A65G37

15CXN-60C

9570D02G03

14RBA4-GNM

9078A33G21

15BA4-80E

116D977A32

15CLE-GNM-C

9078A68G34

15CXN-75C

9570D02G04

14RBA4-GNM

9078A33G21

15BA4-NH

310C196G02

15CLE-GNM-D

9078A68G38

15CXN-85C

9570D02G05

14RBA4-PDM

9078A19G03

15BHLE-100E

5984C05G10

15CLE-HPDM-C

9078A65G14

15CXN-DF-G

9570D06G05

14RBA4-PDM

9078A19G03

15BHLE-10E

5984C05G01

15CLE-HPDM-D

9078A65G19

15CXN-DL-F

9570D34G02

14RBA4-PNM

9078A33G08

15BHLE-125E

5984C05G11

15CLE-HPNM-C

9078A68G14

15CXN-DL-G

9570D06G03

14RBA4-PNM

9078A33G08

15BHLE-150E

5984C05G12

15CLE-HPNM-D

9078A68G19

15CXN-GDM-F

9570D34G01

14RBA8-GNM

9078A33G24

15BHLE-15E

5984C05G02

15CLE-PDM-C

9078A65G13

15CXN-GDM-G

9570D06G01

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A3-1

Appendix 3—Catalog Number/Style Number Cross Reference

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

15CXN-GNM-D

9570D33G03

15HLE-GDM-D

5981C03G06

15RBA2-INH-B

5981C18G02

15RBA4-INH-B

5981C17G02

15CXN-GNM-F

9570D33G01

15HLE-GDM-E

5981C03G18

15RBA2-INH-B

5981C18G02

15RBA4-ISHNT

678C283G06

15CXN-GNM-G

9570D05G02

15HLE-GNM-D

5981C03G12

15RBA2-ISHNT

309C548G10

15RBA4-ISHNT

678C283G06

15CXN-NL-D

9570D33G04

15HLE-GNM-E

5981C03G24

15RBA2-NH

677C370G02

15RBA4-NH

677C371G02

15CXN-NL-F

9570D33G02

15HLE-PDM-D

5981C03G03

15RBA2-NH

677C370G02

15RBA4-NH

677C371G02

15CXN-NL-G

9570D05G06

15HLE-PDM-E

5981C03G15

15RBA2-NL

9078A30A01

15RBA4-NL

9078A30A03

15DBA1-0.5

5980C15G21

15HLE-PNM-D

5981C03G09

15RBA2-NL

9078A30A01

15RBA4-NL

9078A30A03

15DBA1-100E

5980C15G34

15HLE-PNM-E

5981C03G21

15RBA2-NL

9078A30A01

15RBA4-NL

9078A30A03

15DBA1-10E

5980C15G25

15LHLE-100E

5984C65G03

15RBA2-NL

9078A30A01

15RBA4-NL

9078A30A03

15DBA1-125E

5980C15G35

15LHLE-125E

5984C65G08

15RBA2-NL

9078A30A01

15RBA4-NL

9078A30A03

15DBA1-150E

5980C15G36

15LHLE-150E

5984C65G09

15RBA2-NL

9078A30A01

15RBA4-NL

9078A30A03

15DBA1-15E

5980C15G26

15LHLE-175E

5984C65G06

15RBA2-NL

9078A30A01

15RBA4-NL

9078A30A03

15DBA1-200E

5980C15G37

15LHLE-200E

5984C65G07

15RBA2-NL

9078A30A01

15RBA4-NL

9078A30A03

15DBA1-20E

5980C15G27

15LHLE2-125E

5984C65G04

15RBA2-PDM

9078A25G05

15RBA4-PDM

9078A19G05

15DBA1-25E

5980C15G28

15LHLE2-150E

5984C65G05

15RBA2-PDM

9078A25G05

15RBA4-PDM

9078A19G05

15DBA1-3

5980C15G22

15LHLE-250E

5984C65G10

15RBA2-PNM

9078A33G25

15RBA4-PNM

9078A33G26

15DBA1-30E

5980C15G29

15LHLE-300E

5984C65G11

15RBA2-PNM

9078A33G25

15RBA4-PNM

9078A33G26

15DBA1-40E

5980C15G30

15LHLE-65E

5984C65G01

15RBA4-.5

5982C44A26

15RBA8-INH

5981C54G02

15DBA1-50E

5980C15G31

15LHLE-80E

5984C65G02

15RBA4-100E

5982C44A39

15RBA8-INH

5981C54G02

15DBA1-5E

5980C15G23

15NCLPT-0.5E-A

5981C07G06

15RBA4-10E

5982C44A30

15RBA8-NL

9078A30A05

15DBA1-65E

5980C15G32

15NCLPT-10E-B

5981C07G01

15RBA4-125E

5982C44A40

15RBA8-NL

9078A30A05

15DBA1-7E

5980C15G24

15NCLPT-1E-A

5981C07G05

15RBA4-150E

5982C44A41

15RBA8-NL

9078A30A05

15DBA1-80E

5980C15G33

15NCLPT-20.5E-A

5981C07G04

15RBA4-15E

5982C44A31

15RBA8-NL

9078A30A05

15HCL-100E

5981C68G06

15NCLPT-3E-B

5981C07G03

15RBA4-175E

5982C44A42

15RBA8-NL

9078A30A05

15HCL-10E

5982C34G01

15NCLPT-5E-B

5981C07G02

15RBA4-200E

5982C44A43

15RBA8-NL

9078A30A05

15HCL-125E

5981C68G07

15RBA2-100E

423D814A34

15RBA4-20E

5982C44A32

15RBA8-NL

9078A30A05

15HCL-150E

5981C61G04

15RBA2-10E

423D814A25

15RBA4-250E

5982C44A44

15RBA8-NL

9078A30A05

15HCL-15E

5982C34G02

15RBA2-125E

423D814A35

15RBA4-25E

5982C44A33

15RBA8-NL

9078A30A05

15HCL-200E

5981C61G03

15RBA2-150E

423D814A36

15RBA4-3

5982C44A27

15RBA8-PNM

9078A33G27

15HCL-20E

5982C34G03

15RBA2-15E

423D814A26

15RBA4-300E

5982C44A45

15RBA8-PNM

9078A33G27

15HCL-250E

5981C61G01

15RBA2-175E

423D814A37

15RBA4-30E

5982C44A34

15RBA8-PNM

9078A33G27

15HCL-25E

5982C34G04

15RBA2-200E

423D814A38

15RBA4-400E

5982C44A47

15RBT2-100E

449D671A34

15HCL-300E

5981C61G02

15RBA2-20E

423D814A27

15RBA4-40E

5982C44A35

15RBT2-125E

449D671A35

15HCL-30E

5982C34G05

15RBA2-25E

423D814A28

15RBA4-50E

5982C44A36

15RBT2-150E

449D671A36

15HCL-40E

5982C34G06

15RBA2-30E

423D814A29

15RBA4-5E

5982C44A28

15RBT2-200E

449D671A38

15HCL-50E

5982C34G07

15RBA2-40E

423D814A30

15RBA4-65E

5982C44A37

15RBT2-20E

449D671A27

15HCL-65E

5981C68G04

15RBA2-50E

423D814A31

15RBA4-7E

5982C44A29

15RBT2-25E

449D671A28

15HCL-80E

5981C68G05

15RBA2-65E

423D814A32

15RBA4-80E

5982C44A38

15RBT2-30E

449D671A29

15HLE-100E

5981C18G09

15RBA2-80E

423D814A33

15RBA4-DH

309C797G02

15RBT2-40E

449D671A30

15HLE-10E

5981C32G01

15RBA2-DH

309C558G02

15RBA4-DH

309C797G02

15RBT2-50E

449D671A31

15HLE-125E

5981C18G10

15RBA2-DH

309C558G02

15RBA4-DL

9078A20A01

15RBT2-65E

449D671A32

15HLE-150E

5981C24G01

15RBA2-DL

9078A26A01

15RBA4-DL

9078A20A01

15RBT2-80E

449D671A33

15HLE-15E

5981C32G02

15RBA2-DL

9078A26A01

15RBA4-DL

9078A20A01

15RBT4-100E

5982C49A39

15HLE-175E

5981C24G02

15RBA2-DL

9078A26A01

15RBA4-DL

9078A20A01

15RBT4-125E

5982C49A40

15HLE-200E

5981C24G03

15RBA2-DL

9078A26A01

15RBA4-DL

9078A20A01

15RBT4-150E

5982C49A41

15HLE-20E

5981C32G03

15RBA2-DL

9078A26A01

15RBA4-DL

9078A20A01

15RBT4-200E

5982C49A43

15HLE-250E

5981C24G04

15RBA2-DL

9078A26A01

15RBA4-DL

9078A20A01

15RBT4-20E

5982C49A32

15HLE-25E

5981C32G04

15RBA2-DL

9078A26A01

15RBA4-DL

9078A20A01

15RBT4-250E

5982C49A44

15HLE-30E

5981C32G05

15RBA2-DL

9078A26A01

15RBA4-IDH

5981C52G02

15RBT4-25E

5982C49A33

15HLE-40E

5981C18G05

15RBA2-IDH

5981C50G02

15RBA4-IDH

5981C52G02

15RBT4-300E

5982C49A45

15HLE-50E

5981C18G06

15RBA2-IDH

5981C50G02

15RBA4-INH

5981C53G02

15RBT4-30E

5982C49A34

15HLE-65E

5981C18G07

15RBA2-INH

5981C51G02

15RBA4-INH

5981C53G02

15RBT4-400E

5982C49A47

15HLE-80E

5981C18G08

15RBA2-INH

5981C51G02

15RBA4-INH-B

5981C17G02

15RBT4-40E

5982C49A35

V14-A3-2

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 3—Catalog Number/Style Number Cross Reference

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

15RBT4-50E

5982C49A36

25BA4-40E

116D977A49

25RBA4-175E

5982C44A67

25RDB2-DH

309C558G07

15RBT4-65E

5982C49A37

25BA4-50E

116D977A50

25RBA4-200E

5982C44A68

25RDB2-DH

309C558G07

15RBT4-80E

5982C49A38

25BA4-5E

116D977A42

25RBA4-20E

5982C44A57

25RDB2-HUM

140D349G18

15RDB2-DH

309C558G06

25BA4-65E

116D977A51

25RBA4-250E

5982C44A69

25RDB2-HVM

140D340G18

15RDB2-DH

309C558G06

25BA4-7E

116D977A43

25RBA4-25E

5982C44A58

25RDB2-SHNT

308C548G03

15RDB2-HUM

140D349G17

25BA4-80E

116D977A52

25RBA4-3

5982C44A52

25RDB2-VM

140D340G13

15RDB2-HVM

140D340G17

25DBA1-0.5

5980C16G01

25RBA4-300E

5982C44A70

25RDB4-DH

310C131G03

15RDB2-SHNT

308C548G02

25DBA1-100E

5980C16G14

25RBA4-30E

5982C44A59

25RDB4-DH

310C131G03

15RDB2-UM

140D349G12

25DBA1-10E

5980C16G05

25RBA4-40E

5982C44A60

25RDB4-DH

310C131G03

15RDB2-UM

140D349G13

25DBA1-125E

5980C16G15

25RBA4-50E

5982C44A61

25RDB4-DH

310C131G03

15RDB2-VM

140D340G12

25DBA1-150E

5980C16G16

25RBA4-5E

5982C44A53

25RDB4-HUM

140D346G18

15RDB4-DH

310C131G02

25DBA1-15E

5980C16G06

25RBA4-65E

5982C44A62

25RDB4-HVM

140D341G18

15RDB4-DH

310C131G02

25DBA1-200E

5980C16G17

25RBA4-7E

5982C44A54

25RDB4-SHNT

678C284G03

15RDB4-DH

310C131G02

25DBA1-20E

5980C16G07

25RBA4-80E

5982C44A63

25RDB4-SHNT

678C284G03

15RDB4-DH

310C131G02

25DBA1-25E

5980C16G08

25RBA4-DH

309C797G03

25RDB4-UM

140D346G13

15RDB4-HUM

140D346G17

25DBA1-3

5980C16G02

25RBA4-IDH

5981C52G03

25RDB4-VM

140D341G13

15RDB4-HVM

140D341G17

25DBA1-30E

5980C16G09

25RBA4-INH

5981C53G03

25RDB8-HUM

140D354G18

15RDB4-SHNT

678C284G02

25DBA1-40E

5980C16G10

25RBA4-INH-B

5981C17G03

25RDB8-HVM

140D342G18

15RDB4-SHNT

678C284G02

25DBA1-50E

5980C16G11

25RBA4-ISHNT

678C283G07

25RDB8-UM

140D354G13

15RDB4-UM

140D346G12

25DBA1-5E

5980C16G03

25RBA4-ISHNT

678C283G07

25RDB8-VM

140D342G13

15RDB4-VM

140D341G12

25DBA1-65E

5980C16G12

25RBA4-NH

677C371G03

2ACLS-12R

591C142G08

15RDB8-HUM

140D354G17

25DBA1-7E

5980C16G04

25RBA4-PDM

9078A19G06

2ACLS-18R

591C143G01

15RDB8-HVM

140D342G17

25DBA1-80E

5980C16G13

25RBA4-PDM

9078A19G06

2ACLS-24R

591C143G02

15RDB8-UM

140D354G12

25RBA2-100E

423D814A54

25RBA4-PNM

9078A33G09

2ACLS-25

591C142G01

15RDB8-VM

140D342G12

25RBA2-10E

423D814A45

25RBA4-PNM

9078A33G09

2ACLS-2R

591C142G02

25BA2-.5

117D123A33

25RBA2-125E

423D814A55

25RBA8-INH

5981C54G03

2ACLS-3R

591C142G03

25BA2-100E

117D123A45

25RBA2-150E

423D814A56

25RBA8-PNM

9078A33G27

2ACLS-4R

591C142G04

25BA2-10E

117D123A36

25RBA2-15E

423D814A46

25RBA8-PNM

9078A33G27

2ACLS-5R

591C142G05

25BA2-125E

117D123A46

25RBA2-175E

423D814A57

25RBA8-PNM

9078A33G27

2ACLS-6R

591C142G06

25BA2-150E

117D123A47

25RBA2-200E

423D814A58

25RBT2-100E

449D671A54

2ACLS-9R

591C142G07

25BA2-15E

117D123A37

25RBA2-20E

423D814A47

25RBT2-125E

449D671A55

2BCLS-12R

5982C47G08

25BA2-200E

117D123A48

25RBA2-25E

423D814A48

25RBT2-150E

449D671A56

2BCLS-18R

5982C47G09

25BA2-20E

117D123A38

25RBA2-30E

423D814A49

25RBT2-200E

449D671A58

2BCLS-24R

5982C47G10

25BA2-25E

117D123A39

25RBA2-40E

423D814A50

25RBT2-20E

449D671A47

2BCLS-25

5982C47G01

25BA2-30E

117D123A40

25RBA2-50E

423D814A51

25RBT2-25E

449D671A48

2BCLS-2R

5982C47G02

25BA2-40E

117D123A41

25RBA2-65E

423D814A52

25RBT2-30E

449D671A49

2BCLS-3R

5982C47G03

25BA2-50E

117D123A42

25RBA2-80E

423D814A53

25RBT2-40E

449D671A50

2BCLS-4R

5982C47G04

25BA2-5E

117D123A34

25RBA2-DH

309C558G03

25RBT2-50E

449D671A51

2BCLS-5R

5982C47G05

25BA2-65E

117D123A43

25RBA2-IDH

5981C50G03

25RBT2-65E

449D671A52

2BCLS-6R

5982C47G06

25BA2-7E

117D123A35

25RBA2-INH

5981C51G03

25RBT2-80E

449D671A53

2BCLS-9R

5982C47G07

25BA2-80E

117D123A44

25RBA2-INH-B

5981C18G03

25RBT4-100E

5982C49A64

2CLE-100E

449D797G06

25BA4-.5

116D977A41

25RBA2-ISHNT

309C548G11

25RBT4-125E

5982C49A65

2CLE-10E

449D797G11

25BA4-100E

116D977A53

25RBA2-NH

676C880G03

25RBT4-150E

5982C49A66

2CLE-125E

449D797G07

25BA4-10E

116D977A44

25RBA2-PDM

9078A25G06

25RBT4-200E

5982C49A68

2CLE-150E

449D797G08

25BA4-125E

116D977A54

25RBA2-PDM

9078A25G06

25RBT4-20E

5982C49A57

2CLE-15E

678C240G01

25BA4-150E

116D977A55

25RBA2-PNM

9078A33G04

25RBT4-250E

5982C49A69

2CLE-200E

449D797G09

25BA4-15E

116D977A45

25RBA2-PNM

9078A33G04

25RBT4-25E

5982C49A58

2CLE-20E

678C240G02

25BA4-200E

116D977A56

25RBA4-.5

5982C44A51

25RBT4-300E

5982C49A70

2CLE-225E

449D797G10

25BA4-20E

116D977A46

25RBA4-100E

5982C44A64

25RBT4-30E

5982C49A59

2CLE-250E

449D797G13

25BA4-250E

116D977A57

25RBA4-10E

5982C44A55

25RBT4-40E

5982C49A60

2CLE-25E

678C240G03

25BA4-25E

116D977A47

25RBA4-125E

5982C44A65

25RBT4-50E

5982C49A61

2CLE-25E

449D797G12

25BA4-300E

116D977A58

25RBA4-150E

5982C44A66

25RBT4-65E

5982C49A62

2CLE-300E

449D797G14

25BA4-30E

116D977A48

25RBA4-15E

5982C44A56

25RBT4-80E

5982C49A63

2CLE-30E

449D797G02

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A3-3

Appendix 3—Catalog Number/Style Number Cross Reference

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

2CLE-350X

449D797G15

38BA2-20E

117D123A54

38DBA2-3

505D420G07

38RBA4-30E

5982C44A84

2CLE-400X

449D797G17

38BA2-25E

117D123A55

38DBA2-30E

18A7330G19

38RBA4-40E

5982C44A85

2CLE-450X

449D797G18

38BA2-30E

117D123A56

38DBA2-40E

18A7330G20

38RBA4-50E

5982C44A86

2CLE-50E

449D797G03

38BA2-40E

117D123A57

38DBA2-50E

18A7330G21

38RBA4-5E

5982C44A78

2CLE-65E

449D797G04

38BA2-50E

117D123A58

38DBA2-5E

18A7330G13

38RBA4-65E

5982C44A87

2CLE-80E

449D797G05

38BA2-5E

117D123A50

38DBA2-65E

18A7330G22

38RBA4-7E

5982C44A79

2CLE-GDM-C

9078A65G30

38BA2-65E

117D123A59

38DBA2-780E

18A7330G23

38RBA4-80E

5982C44A88

2CLE-GDM-D

9078A65G34

38BA2-7E

117D123A51

38DBA2-7E

18A7330G14

38RBA4-DH

309C797G04

2CLE-GDM-E

9078A65G38

38BA2-80E

117D123A60

38RBA2-100E

423D814A74

38RBA4-DL

9078A20A02

2CLE-GNM-C

9078A68G31

38BA4-.5

116D977A61

38RBA2-10E

423D814A65

38RBA4-IDH

5981C52G04

2CLE-GNM-D

9078A68G35

38BA4-100E

116D977A73

38RBA2-125E

423D814A75

38RBA4-INH

5981C53G04

2CLE-GNM-E

9078A68G39

38BA4-10E

116D977A64

38RBA2-150E

423D814A76

38RBA4-INH-B

5981C17G04

2CLE-PDM-C

9078A65G10

38BA4-125E

116D977A74

38RBA2-15E

423D814A66

38RBA4-ISHNT

678C283G08

2CLE-PDM-D

9078A65G15

38BA4-150E

116D977A75

38RBA2-175E

423D814A77

38RBA4-ISHNT

678C283G08

2CLE-PDM-E

9078A65G20

38BA4-15E

116D977A65

38RBA2-200E

423D814A78

38RBA4-NH

677C371G04

2CLE-PNM-C

9078A68G10

38BA4-200E

116D977A76

38RBA2-20E

423D814A67

38RBA4-NL

9078A30A04

2CLE-PNM-D

9078A68G15

38BA4-20E

116D977A66

38RBA2-25E

423D814A68

38RBA4-NL

9078A30A04

2CLE-PNM-E

9078A68G20

38BA4-250E

116D977A77

38RBA2-30E

423D814A69

38RBA4-PDM

9078A19G07

2CLS-12R

591C812G08

38BA4-25E

116D977A67

38RBA2-40E

423D814A70

38RBA4-PDM

9078A19G07

2CLS-18R

591C813G01

38BA4-300E

116D977A78

38RBA2-50E

423D814A71

38RBA4-PNM

9078A33G10

2CLS-24R

591C813G02

38BA4-30E

116D977A68

38RBA2-65E

423D814A72

38RBA4-PNM

9078A33G10

2CLS-25

591C812G01

38BA4-40E

116D977A69

38RBA2-80E

423D814A73

38RBA8-INH

5981C54G04

2CLS-2R

591C812G02

38BA4-50E

116D977A70

38RBA2-DH

309C558G04

38RBA8-NL

9078A30A06

2CLS-3R

591C812G03

38BA4-5E

116D977A62

38RBA2-DL

9078A26A02

38RBA8-NL

9078A30A06

2CLS-4R

591C812G04

38BA4-65E

116D977A71

38RBA2-DL

9078A26A02

38RBA8-NL

9078A30A06

2CLS-5R

591C812G05

38BA4-7E

116D977A63

38RBA2-DL

9078A26A02

38RBA8-PNM

9078A33G15

2CLS-6R

591C812G06

38BA4-80E

116D977A72

38RBA2-DL

9078A26A02

38RBA8-PNM

9078A33G15

2CLS-9R

591C812G07

38DBA1-0.5

5980C16G21

38RBA2-IDH

5981C50G04

38RBA8-PNM

9078A33G15

2CLT-12C

678C249G01

38DBA1-100E

5980C16G34

38RBA2-INH

5981C51G04

38RBT2-100E

449D671A74

2CLT-150C

680C387G01

38DBA1-10E

5980C16G25

38RBA2-INH-B

5981C18G04

38RBT2-125E

449D671A75

2CLT-18C

678C276G01

38DBA1-125E

5980C16G35

38RBA2-ISHNT

309C548G12

38RBT2-150E

449D671A76

2CLT-25C

678C276G04

38DBA1-150E

5980C16G36

38RBA2-NH

677C370G04

38RBT2-200E

449D671A78

2CLT-30C

678C277G04

38DBA1-15E

5980C16G26

38RBA2-NL

9078A30A02

38RBT2-20E

449D671A67

2CLT-5C

678C248G01

38DBA1-200E

5980C16G37

38RBA2-NL

9078A30A02

38RBT2-25E

449D671A68

2CLT-75C

678C282G01

38DBA1-20E

5980C16G27

38RBA2-NL

9078A30A02

38RBT2-30E

449D671A69

2CLT-90C

680C387G02

38DBA1-25E

5980C16G28

38RBA2-NL

9078A30A02

38RBT2-40E

449D671A70

2HCLS-12R

591C155G08

38DBA1-3

5980C16G22

38RBA2-PDM

9078A25G07

38RBT2-50E

449D671A71

2HCLS-18R

591C157G01

38DBA1-30E

5980C16G29

38RBA2-PDM

9078A25G07

38RBT2-65E

449D671A72

2HCLS-24R

591C157G02

38DBA1-40E

5980C16G30

38RBA2-PNM

9078A33G05

38RBT2-80E

449D671A73

2HCLS-25

591C155G01

38DBA1-50E

5980C16G31

38RBA2-PNM

9078A33G05

38RBT4-100E

5982C49A89

2HCLS-2R

591C155G02

38DBA1-5E

5980C16G23

38RBA4-.5

5982C44A76

38RBT4-125E

5982C49A90

2HCLS-3R

591C155G03

38DBA1-65E

5980C16G32

38RBA4-100E

5982C44A89

38RBT4-150E

5982C49A91

2HCLS-4R

591C155G04

38DBA1-7E

5980C16G24

38RBA4-10E

5982C44A80

38RBT4-200E

5982C49A93

2HCLS-5R

591C155G05

38DBA1-80E

5980C16G33

38RBA4-125E

5982C44A90

38RBT4-20E

5982C49A82

2HCLS-6R

591C155G06

38DBA2-.5

22A6782G04

38RBA4-150E

5982C44A91

38RBT4-250E

5982C49A94

2HCLS-9R

591C155G07

38DBA2-100E

18A7330G24

38RBA4-15E

5982C44A81

38RBT4-25E

5982C49A83

38BA2-.5

117D123A49

38DBA2-10E

18A7330G15

38RBA4-175E

5982C44A92

38RBT4-300E

5982C49A95

38BA2-100E

117D123A61

38DBA2-125E

18A7330G25

38RBA4-200E

5982C44A93

38RBT4-30E

5982C49A84

38BA2-10E

117D123A52

38DBA2-150E

18A7330G26

38RBA4-20E

5982C44A82

38RBT4-40E

5982C49A85

38BA2-125E

117D123A62

38DBA2-15E

18A7330G16

38RBA4-250E

5982C44A94

38RBT4-50E

5982C49A86

38BA2-150E

117D123A63

38DBA2-200E

18A7330G27

38RBA4-25E

5982C44A83

38RBT4-65E

5982C49A87

38BA2-15E

117D123A53

38DBA2-20E

18A7330G17

38RBA4-3

5982C44A77

38RBT4-80E

5982C49A88

38BA2-200E

117D123A64

38DBA2-25E

18A7330G18

38RBA4-300E

5982C44A95

38RDB2-DH

309C558G08

V14-A3-4

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 3—Catalog Number/Style Number Cross Reference

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

38RDB2-DH

309C558G08

48DBA2-7E

18A7330G34

5AHLE-350E

5981C46G17

5CLE-15E

678C240G04

38RDB2-HUM

140D349G19

4ACLS-26R

151D207G01

5AHLE-400E

5981C46G18

5CLE-15E-D

5981C29G02

38RDB2-HVM

140D340G19

4BCLS-26R

5982C32G03

5AHLE-40E

5981C46G06

5CLE-175E

5981C65G08

38RDB2-SHNT

308C548G04

4CX-100C

5978C66G05

5AHLE-450E

5981C46G19

5CLE-200E

5981C65G09

38RDB2-UM

140D349G14

4CX-18C

5978C62G01

5AHLE-50E

5981C46G07

5CLE-20E

678C240G05

38RDB2-VM

140D340G14

4CX-25C

5978C62G02

5AHLE-65E

5981C46G08

5CLE-20E-D

5981C29G03

38RDB4-DH

310C131G04

4CX-35C

5978C62G03

5AHLE-80E

5981C46G09

5CLE-250E

5981C65G10

38RDB4-DH

310C131G04

4CX-45C

5978C66G01

5BCLS-12R

5982C31G08

5CLE-25E

678C240G06

38RDB4-DH

310C131G04

4CX-50C

5978C66G02

5BCLS-18R

5982C32G01

5CLE-25E-D

5981C29G04

38RDB4-DH

310C131G04

4CX-60C

151D253G06

5BCLS-24R

5982C32G02

5CLE-300E

5981C67G01

38RDB4-HUM

140D346G19

4CX-65C

5978C66G03

5BCLS-2R

5982C31G02

5CLE-30E

5981C29G05

38RDB4-HVM

140D341G19

4CX-75C

5978C66G04

5BCLS-30

5982C31G01

5CLE-350E

5981C67G02

38RDB4-SHNT

678C284G04

4CX-80C

151D253G08

5BCLS-32R

9570D64G01

5CLE-400E

5981C67G03

38RDB4-SHNT

678C284G04

4CXI-100C

5978C66G25

5BCLS-36R

9570D64G02

5CLE-40E

5981C65G01

38RDB4-UM

140D346G14

4CXI-18C

5978C62G21

5BCLS-3R

5982C31G03

5CLE-450E

5981C67G04

38RDB4-VM

140D341G14

4CXI-25C

5978C62G22

5BCLS-44R

9570D64G03

5CLE-50E

5981C65G02

38RDB8-HUM

140D354G19

4CXI-35C

5978C62G23

5BCLS-4R

5982C31G04

5CLE-600E

449D595G02

38RDB8-HVM

140D342G19

4CXI-45C

5978C66G21

5BCLS-5R

5982C31G05

5CLE-65E

5981C65G03

38RDB8-UM

140D354G14

4CXI-50C

5978C66G22

5BCLS-600E

9570D64G04

5CLE-750E

449D595G01

38RDB8-VM

140D342G14

4CXI-60C

151D253G26

5BCLS-6R

5982C31G06

5CLE-80E

5981C65G04

48DBA1-0.5

5980C17G01

4CXI-65C

5978C66G23

5BCLS-750E

9570D64G05

5CLE-GDM-C

9078A65G31

48DBA1-100E

5980C17G14

4CXI-75C

5978C66G24

5BCLS-9R

5982C31G07

5CLE-GDM-D

9078A65G35

48DBA1-10E

5980C17G05

4CXI-80C

151D253G28

5BHCL-400E

5981C62G11

5CLE-GDM-E

9078A65G39

48DBA1-125E

5980C17G15

4NPL-1300

140D318G05

5BHCL-450E

5981C62G10

5CLE-GNM-C

9078A68G32

48DBA1-150E

5980C17G16

4NPL-1875

140D318G01

5BHCL-500E

5981C62G09

5CLE-GNM-D

9078A68G36

48DBA1-15E

5980C17G06

4NPL-2000

140D318G07

5BHCL-600E

5981C62G08

5CLE-GNM-E

9078A68G40

48DBA1-200E

5980C17G17

4NPL-2825

140D318G02

5BHCL-750E

5981C58G01

5CLE-PDM-C

9078A65G11

48DBA1-20E

5980C17G07

4NPL-3000

140D318G06

5BHCL-900E

5981C58G02

5CLE-PDM-D

9078A65G16

48DBA1-25E

5980C17G08

4NPL-3500

5982C64G01

5BHLE-100E

5983C02G10

5CLE-PDM-E

9078A65G21

48DBA1-3

5980C17G02

4NPL-5000

5982C64G02

5BHLE-10E

5983C02G01

5CLE-PNM-C

9078A68G11

48DBA1-30E

5980C17G09

4NPL-900

140D318G04

5BHLE-125E

5983C02G11

5CLE-PNM-D

9078A68G16

48DBA1-40E

5980C17G10

5ACLS-12R

151D933G02

5BHLE-150E

5983C02G12

5CLE-PNM-E

9078A68G21

48DBA1-50E

5980C17G11

5ACLS-18R

151D933G03

5BHLE-15E

5983C02G02

5CLS-12R

151D961G02

48DBA1-5E

5980C17G03

5ACLS-24R

151D933G04

5BHLE-175E

5983C02G13

5CLS-18R

151D961G03

48DBA1-65E

5980C17G12

5ACLS-2R

449D597G02

5BHLE-200E

5983C02G14

5CLS-24R

151D961G04

48DBA1-7E

5980C17G04

5ACLS-30

449D597G01

5BHLE-20E

5983C02G03

5CLS-2R

151D241G02

48DBA1-80E

5980C17G13

5ACLS-3R

449D597G03

5BHLE-250E

5983C02G15

5CLS-30

151D241G01

48DBA2-.5

22A6782G05

5ACLS-4R

449D597G04

5BHLE-25E

5983C02G04

5CLS-3R

151D241G03

48DBA2-100E

18A7330G44

5ACLS-5R

449D597G05

5BHLE-300E

5983C02G16

5CLS-4R

151D241G04

48DBA2-10E

18A7330G35

5ACLS-6R

449D597G06

5BHLE-30E

5983C02G05

5CLS-5R

151D241G05

48DBA2-125E

18A7330G45

5ACLS-9R

151D933G01

5BHLE-350E

5983C02G17

5CLS-6R

151D241G06

48DBA2-150E

18A7330G46

5AHLE-100E

5981C46G10

5BHLE-400E

5983C02G18

5CLS70-12R

140D045G04

48DBA2-15E

18A7330G36

5AHLE-10E

5981C46G01

5BHLE-40E

5983C02G06

5CLS70-18R

140D045G06

48DBA2-200E

18A7330G47

5AHLE-125E

5981C46G11

5BHLE-450E

5983C02G19

5CLS70-24R

140D045G03

48DBA2-20E

18A7330G37

5AHLE-150E

5981C46G12

5BHLE-50E

5983C02G07

5CLS70-2R

5981C81G06

48DBA2-25E

18A7330G38

5AHLE-15E

5981C46G02

5BHLE-65E

5983C02G08

5CLS70-32R

140D045G01

48DBA2-3

505D420G08

5AHLE-175E

5981C46G13

5BHLE-80E

5983C02G09

5CLS70-36R

140D045G02

48DBA2-30E

18A7330G39

5AHLE-200E

5981C46G14

5CLE-100E

5981C65G05

5CLS70-3R

5981C81G05

48DBA2-40E

18A7330G40

5AHLE-20E

5981C46G03

5CLE-10E-D

5981C29G01

5CLS70-44R

140D045G05

48DBA2-50E

18A7330G41

5AHLE-250E

5981C46G15

5CLE-1100E

9570D70G01

5CLS70-4R

5981C81G04

48DBA2-5E

18A7330G33

5AHLE-25E

5981C46G04

5CLE-125E

5981C65G06

5CLS70-5R

5981C81G03

48DBA2-65E

18A7330G42

5AHLE-300E

5981C46G16

5CLE-1350E

9570D70G02

5CLS70-6R

5981C81G12

48DBA2-780E

18A7330G43

5AHLE-30E

5981C46G05

5CLE-150E

5981C65G07

5CLS70-9R

5981C81G01

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-A3-5

Appendix 3—Catalog Number/Style Number Cross Reference

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

5CLS75-24R

151D257G05

5HCL-500E

5981C62G01

5NCLPT-1E-A

5981C05G05

6MDSL-MA800

5982C90G08

5CLS75-32R

151D257G02

5HCL-50E

5981C65G07

5NCLPT-2E-A

5981C05G04

6MDSL-MB1200

5982C91G01

5CLS75-36R

151D257G01

5HCL-600E

5981C62G02

5NCLPT-3E-A

5981C05G03

6MDSL-MB1600

5982C91G02

5CLS-9R

151D961G01

5HCL-65E

5981C65G08

5NCLPT-5E-A

5981C05G02

6MDSL-MB2000

5982C91G03

5CLT-12C

678C249G02

5HCL-80E

5981C65G09

5RBA2-GDM

9078A25G02

6MDSL-MC1000

5982C92G02

5CLT-18C

678C276G02

5HCLS-12R

151D962G02

5RBA2-GDM

9078A25G02

6MDSL-MC1200

5982C92G03

5CLT-25C

678C276G05

5HCLS-18R

151D962G03

5RBA2-GNM

9078A33G16

6MDSL-MC1600

5982C92G04

5CLT-30C

680C386G02

5HCLS-24R

151D962G04

5RBA2-GNM

9078A33G16

6MDSL-MC2000

5982C92G05

5CLT-45C

680C386G05

5HCLS-2R

151D240G02

5RBA2-PDM

9078A25G01

6MDSL-MC800

5982C92G01

5CLT-60C

680C386G03

5HCLS-30

151D240G01

5RBA2-PDM

9078A25G01

6MDSL-MD2500

5982C93G01

5CLT-8C

678C248G05

5HCLS-3R

151D240G03

5RBA2-PNM

9078A33G06

6MDSL-MD3000

5982C93G02

5CX-10C

151D254G11

5HCLS-4R

151D240G04

5RBA2-PNM

9078A33G06

72DBA1-0.5

5980C17G21

5CX-12C

151D254G12

5HCLS-5R

151D240G05

5RBA4-GDM

9078A19G02

72DBA1-100E

5980C17G34

5CX-18C

5978C70G01

5HCLS-6R

151D240G06

5RBA4-GDM

9078A19G02

72DBA1-10E

5980C17G25

5CX-20C

5978C70G02

5HCLS-9R

151D962G01

5RBA4-GNM

9078A33G19

72DBA1-125E

5980C17G35

5CX-21C

151D254G04

5HLE-100E

5981C64G05

5RBA4-GNM

9078A33G19

72DBA1-150E

5980C17G36

5CX-25C

151D254G03

5HLE-10E

5981C28G01

5RBA4-PDM

9078A19G01

72DBA1-15E

5980C17G26

5CX-30C

5978C70G04

5HLE-125E

5981C64G06

5RBA4-PDM

9078A19G01

72DBA1-200E

5980C17G37

5CX-35C

151D254G06

5HLE-150E

5981C64G07

5RBA4-PNM

9078A33G06

72DBA1-20E

5980C17G27

5CX-40C

5978C70G05

5HLE-15E

5981C28G02

5RBA4-PNM

9078A33G06

72DBA1-25E

5980C17G28

5CX-50C

5978C70G06

5HLE-175E

5981C64G08

5RBA8-GNM

9078A33G22

72DBA1-3

5980C17G22

5CX-60C

151D254G09

5HLE-200E

5981C64G09

5RBA8-GNM

9078A33G22

72DBA1-30E

5980C17G29

5CX-65C

5978C70G07

5HLE-20E

5981C28G03

5RBA8-GNM

9078A33G22

72DBA1-40E

5980C17G30

5CX-75C

5978C70G08

5HLE-250E

5981C64G10

5RBA8-PNM

9078A33G22

72DBA1-50E

5980C17G31

5CX-GDM-G

151D885G01

5HLE-25E

5981C28G04

5RBA8-PNM

9078A33G22

72DBA1-5E

5980C17G23

5CX-GNM-G

151D884G01

5HLE-300E

5981C66G01

5RBA8-PNM

9078A33G22

72DBA1-65E

5980C17G32

5CXI-10C

151D254G31

5HLE-30E

5981C28G05

6DSL-A150

140D316G01

72DBA1-7E

5980C17G24

5CXI-12C

151D254G32

5HLE-350E

5981C66G02

6DSL-A200

140D316G02

72DBA1-80E

5980C17G33

5CXI-18C

5978C70G21

5HLE-400E

5981C66G03

6DSL-A250

140D316G03

72DBA2-.5

22A6782G06

5CXI-20C

5978C70G22

5HLE-40E

5981C64G01

6DSL-A300

140D316G04

72DBA2-100E

11A8127G13

5CXI-21C

151D254G24

5HLE-450E

5981C66G04

6DSL-A400

140D316G05

72DBA2-10E

11A8127G04

5CXI-25C

151D254G23

5HLE-50E

5981C64G02

6DSL-A600

140D316G06

72DBA2-125E

11A8127G14

5CXI-30C

5978C70G24

5HLE-65E

5981C64G03

6DSL-A800

140D316G07

72DBA2-150E

11A8127G15

5CXI-35C

151D254G26

5HLE-80E

5981C64G04

6DSL-B1200

140D316G10

72DBA2-15E

11A8127G05

5CXI-40C

5978C70G25

5HLE-GDM-D

5981C03G04

6DSL-B1600

140D316G11

72DBA2-200E

11A8127G16

5CXI-50C

5978C70G26

5HLE-GDM-E

5981C03G16

6DSL-B3000

140D316G12

72DBA2-20E

11A8127G06

5CXI-60C

151D254G29

5HLE-GNM-D

5981C03G10

6DSL-C1000

151D932G02

72DBA2-25E

11A8127G07

5CXI-65C

5978C70G27

5HLE-GNM-E

5981C03G22

6DSL-C1200

151D932G03

72DBA2-3

505D420G09

5CXI-75C

5978C70G28

5HLE-PDM-D

5981C03G01

6DSL-C1600

151D932G04

72DBA2-30E

11A8127G08

5HCL-100E

5981C65G10

5HLE-PDM-E

5981C03G13

6DSL-C2000

151D932G05

72DBA2-40E

11A8127G09

5HCL-10E

5981C29G01

5HLE-PNM-D

5981C03G07

6DSL-C800

151D932G01

72DBA2-50E

11A8127G10

5HCL-125E

5981C65G11

5HLE-PNM-E

5981C03G19

6DSL-D2500

151D932G09

72DBA2-5E

11A8127G02

5HCL-150E

5981C65G12

5LCLS-12R

676C546G25

6DSL-D3000

151D932G10

72DBA2-65E

11A8127G11

5HCL-15E

5981C29G02

5LCLS-18R

304C463G03

6DSL-E2500

5980C01G01

72DBA2-7E

11A8127G03

5HCL-200E

5981C62G07

5LCLS-24R

304C463G04

6DSL-E3000

5980C01G02

72DBA2-80E

11A8127G12

5HCL-20E

5981C29G03

5LCLS-2R

676C546G15

6DSL-E4000

5980C01G03

7ACLS-12R

151D963G07

5HCL-250E

5981C62G06

5LCLS-3R

676C546G16

6DSL-F5000

5980C01G04

7ACLS18R

151D963G10

5HCL-25E

5981C29G04

5LCLS-4R

676C546G17

6MDSL-MA150

5982C90G01

7ACLS-24R

151D963G11

5HCL-300E

5981C62G05

5LCLS-5R

676C546G18

6MDSL-MA200

5982C90G02

7ACLS-9R

151D963G06

5HCL-30E

5981C29G05

5LCLS-6R

676C546G19

6MDSL-MA250

5982C90G03

7BCLS-12R

5982C36G07

5HCL-400E

5981C62G04

5LCLS-9R

676C546G22

6MDSL-MA300

5982C90G04

7BCLS-18R

5982C36G08

5HCL-40E

5981C65G06

5NCLPT-0.5E-A

5981C05G06

6MDSL-MA400

5982C90G05

7BCLS-24R

5982C36G09

5HCL-450E

5981C62G03

5NCLPT-10E-A

5981C05G01

6MDSL-MA600

5982C90G07

7BCLS-2R

5982C36G01

V14-A3-6

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Style Number

Appendix 3—Catalog Number/Style Number Cross Reference

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

7BCLS-3R

5982C36G02

8BA4-.5

116D977A01

8CLE-40E

5981C17G04

8CX-8C

5978C62G06

7BCLS-44R

9570D69G01

8BA4-100E

116D977A13

8CLE-50E

5981C17G05

8CX-GDM-G

151D885G02

7BCLS-44R

9570D69G01

8BA4-10E

116D977A04

8CLE-65E

5981C17G06

8CX-GNM-G

151D884G02

7BCLS-4R

5982C36G03

8BA4-125E

116D977A14

8CLE-80E

5981C17G07

8CXI-10C

151D255G31

7BCLS-5R

5982C36G04

8BA4-150E

116D977A15

8CLE-GDM-C

9078A65G32

8CXI-12C

151D255G32

7BCLS-6R

5982C36G05

8BA4-15E

116D977A05

8CLE-GDM-D

9078A65G36

8CXI-15C

151D255G26

7BCLS-9R

5982C36G06

8BA4-200E

116D977A16

8CLE-GDM-E

9078A65G40

8CXI-18C

5978C72G21

7CLS-12R

5982C01G07

8BA4-20E

116D977A06

8CLE-GNM-C

9078A68G33

8CXI-20C

5978C72G22

7CLS-18R

5982C01G10

8BA4-250E

116D977A17

8CLE-GNM-D

9078A68G37

8CXI-25C

5978C72G23

7CLS-24R

5982C01G11

8BA4-25E

116D977A07

8CLE-GNM-E

9078A68G41

8CXI-3.5C

151D255G21

7CLS70-24R

5979C91G01

8BA4-300E

116D977A18

8CLE-PDM-C

9078A65G12

8CXI-30C

5978C72G24

7CLS70-36R

5979C91G02

8BA4-30E

116D977A08

8CLE-PDM-D

9078A65G17

8CXI-35C

151D255G29

7CLS70-44R

5980C03G01

8BA4-400E

116D977A19

8CLE-PDM-E

9078A65G22

8CXI-4.5C

5978C62G24

7CLS-9R

5982C01G06

8BA4-40E

116D977A09

8CLE-PNM-C

9078A68G12

8CXI-40C

5978C72G25

8ACLS-2R

151D963G01

8BA4-50E

116D977A10

8CLE-PNM-D

9078A68G17

8CXI-4C

151D255G22

8ACLS-3R

151D963G02

8BA4-5E

116D977A02

8CLE-PNM-E

9078A68G22

8CXI-6C

5978C62G25

8ACLS-4R

151D963G03

8BA4-65E

116D977A11

8CLS-110

151D256G06

8CXI-7C

151D255G23

8ACLS-5R

151D963G04

8BA4-7E

116D977A03

8CLS-125

151D256G07

8CXI-8C

5978C62G26

8ACLS-6R

151D963G05

8BA4-80E

116D977A12

8CLS-15

151D256G01

8CXN-100C

9570D01G02

8AHLE-100E

5981C47G10

8BA4-NH

310C196G01

8CLS-150

151D256G11

8CXN-125C

9570D01G03

8AHLE-10E

5981C47G01

8BHLE-100E

5983C03G10

8CLS-200

151D256G12

8CXN-150C

9570D01G04

8AHLE-125E

5981C47G11

8BHLE-10E

5983C03G01

8CLS-225

151D256G13

8CXN-200C

9570D01G05

8AHLE-150E

5981C47G12

8BHLE-125E

5983C03G11

8CLS-2R

5982C01G01

8CXN-250C

9570D01G06

8AHLE-15E

5981C47G02

8BHLE-150E

5983C03G12

8CLS-30

151D256G02

8CXN-60C

9570D01G01

8AHLE-175E

5981C47G13

8BHLE-15E

5983C03G02

8CLS-3R

5982C01G02

8DBA1-0.5

5980C15G01

8AHLE-200E

5981C47G14

8BHLE-175E

5983C03G13

8CLS-4R

5982C01G03

8DBA1-100E

5980C15G14

8AHLE-20E

5981C47G03

8BHLE-200E

5983C03G14

8CLS-5R

5982C01G04

8DBA1-10E

5980C15G05

8AHLE-250E

5981C47G15

8BHLE-20E

5983C03G03

8CLS-60

151D256G03

8DBA1-125E

5980C15G15

8AHLE-25E

5981C47G04

8BHLE-250E

5983C03G15

8CLS-6R

5982C01G05

8DBA1-150E

5980C15G16

8AHLE-300E

5981C47G16

8BHLE-25E

5983C03G04

8CLS-70

151D256G04

8DBA1-15E

5980C15G06

8AHLE-30E

5981C47G05

8BHLE-300E

5983C03G16

8CLS-90

151D256G05

8DBA1-200E

5980C15G17

8AHLE-350E

5981C47G17

8BHLE-30E

5983C03G05

8CLT-12C

591C273G03

8DBA1-20E

5980C15G07

8AHLE-40E

5981C47G06

8BHLE-350E

5983C03G17

8CLT-18C

678C276G03

8DBA1-25E

5980C15G08

8AHLE-50E

5981C47G07

8BHLE-40E

5983C03G06

8CLT-25C

678C276G06

8DBA1-3

5980C15G02

8AHLE-65E

5981C47G08

8BHLE-50E

5983C03G07

8CLT-30CL

678C290G01

8DBA1-30E

5980C15G09

8AHLE-80E

5981C47G09

8BHLE-65E

5983C03G08

8CLT-30CS

680C386G01

8DBA1-40E

5980C15G10

8BA2-.5

117D123A01

8BHLE-80E

5983C03G09

8CLT-45C

680C386G06

8DBA1-50E

5980C15G11

8BA2-100E

117D123A13

8CLE-100E

5981C17G08

8CLT-5C

678C248G03

8DBA1-5E

5980C15G03

8BA2-10E

117D123A04

8CLE-10E

5981C31G01

8CLT-8C

678C248G06

8DBA1-65E

5980C15G12

8BA2-125E

117D123A14

8CLE-125E

5981C17G09

8CX-10C

151D255G11

8DBA1-7E

5980C15G04

8BA2-150E

117D123A15

8CLE-150E

5981C17G10

8CX-12C

151D255G12

8DBA1-80E

5980C15G13

8BA2-15E

117D123A05

8CLE-15E

678C240G07

8CX-15C

151D255G06

8HCL-100E

5983C05G08

8BA2-200E

117D123A16

8CLE-15E-D

5981C31G02

8CX-18C

5978C72G01

8HCL-125E

5983C05G07

8BA2-20E

117D123A06

8CLE-175E

5981C17G11

8CX-20C

5978C72G02

8HCL-150E

5983C05G06

8BA2-25E

117D123A07

8CLE-200E

5981C21G01

8CX-25C

5978C72G03

8HCL-175E

5983C05G05

8BA2-30E

117D123A08

8CLE-20E

678C240G08

8CX-3.5C

151D255G01

8HCL-200E

5983C05G01

8BA2-40E

117D123A09

8CLE-20E-D

5981C31G03

8CX-30C

5978C72G04

8HCL-250E

5983C05G02

8BA2-50E

117D123A10

8CLE-250E

5981C21G02

8CX-35C

151D255G09

8HCL-300E

5983C05G03

8BA2-5E

117D123A02

8CLE-25E

678C240G09

8CX-4.5C

5978C62G04

8HCL-350E

5983C05G04

8BA2-65E

117D123A11

8CLE-25E-D

5981C31G04

8CX-40C

5978C72G05

8HCL-65E

5983C05G10

8BA2-7E

117D123A03

8CLE-300E

5981C21G03

8CX-4C

151D255G02

8HCL-80E

5983C05G09

8BA2-80E

117D123A12

8CLE-30E

5981C31G05

8CX-6C

5978C62G05

8HLE-100E

5981C16G08

8BA2-NH

310C198G01

8CLE-350E

5981C21G04

8CX-7C

151D255G03

8HLE-10E

5981C30G01

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Style Number

V14-A3-7

Appendix 3—Catalog Number/Style Number Cross Reference

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

8HLE-125E

5981C16G09

8RBA2-INH-B

5984C18G01

8RBA8-INH

5981C54G01

92DBA2-125E

11A8127G34

8HLE-150E

5981C16G10

8RBA2-INH-B

5984C18G01

8RBA8-INH

5981C54G01

92DBA2-150E

11A8127G35

8HLE-15E

5981C30G02

8RBA2-ISHNT

309C548G09

8RBA8-PNM

9078A33G12

92DBA2-15E

11A8127G25

8HLE-175E

5981C16G11

8RBA2-NH

677C370G01

8RBA8-PNM

9078A33G12

92DBA2-200E

11A8127G36

8HLE-200E

5981C22G01

8RBA2-NH

677C370G01

8RBA8-PNM

9078A33G12

92DBA2-20E

11A8127G26

8HLE-20E

5981C30G03

8RBA2-PDM

9078A25G08

8RBT2-100E

449D671A14

92DBA2-25E

11A8127G27

8HLE-250E

5981C22G02

8RBA2-PDM

9078A25G08

8RBT2-125E

449D671A15

92DBA2-3

11A8127G21

8HLE-25E

5981C30G04

8RBA2-PNM

9078A33G02

8RBT2-150E

449D671A16

92DBA2-30E

11A8127G28

8HLE-300E

5981C22G03

8RBA2-PNM

9078A33G02

8RBT2-200E

449D671A18

92DBA2-40E

11A8127G29

8HLE-30E

5981C30G05

8RBA4-.5

5982C44A01

8RBT2-20E

449D671A07

92DBA2-50E

11A8127G30

8HLE-350E

5981C22G04

8RBA4-100E

5982C44A14

8RBT2-25E

449D671A08

92DBA2-5E

11A8127G22

8HLE-40E

5981C16G04

8RBA4-10E

5982C44A05

8RBT2-30E

449D671A09

92DBA2-65E

11A8127G31

8HLE-50E

5981C16G05

8RBA4-125E

5982C44A15

8RBT2-40E

449D671A10

92DBA2-780E

11A8127G32

8HLE-65E

5981C16G06

8RBA4-150E

5982C44A16

8RBT2-50E

449D671A11

92DBA2-7E

11A8127G23

8HLE-80E

5981C16G07

8RBA4-15E

5982C44A06

8RBT2-65E

449D671A12

CLE-DF-C

9078A63G02

8HLE-GDM-D

5981C03G05

8RBA4-175E

5982C44A17

8RBT2-80E

449D671A13

CLE-DF-D

9078A63G03

8HLE-GDM-E

5981C03G14

8RBA4-200E

5982C44A18

8RBT4-100E

5982C49A14

CLE-DF-E

9078A63G04

8HLE-GNM-D

5981C03G11

8RBA4-20E

5982C44A07

8RBT4-125E

5982C49A15

CLE-DL-C

9078A63G04

8HLE-GNM-E

5981C03G23

8RBA4-250E

5982C44A19

8RBT4-150E

5982C49A16

CLE-DL-D

9078A67G03

8HLE-PDM-D

5981C03G02

8RBA4-25E

5982C44A08

8RBT4-200E

5982C49A18

CLE-DL-E

9078A64G04

8HLE-PDM-E

5981C03G14

8RBA4-3

5982C44A02

8RBT4-20E

5982C49A07

CLE-NL-C

9078A67G02

8HLE-PNM-D

5981C03G08

8RBA4-300E

5982C44A20

8RBT4-250E

5982C49A19

CLE-NLC-C

9078A67G17

8HLE-PNM-E

5981C03G20

8RBA4-30E

5982C44A09

8RBT4-25E

5982C49A08

CLE-NLC-D

9078A67G20

8NCLPT-0.5E-A

5981C06G06

8RBA4-400E

5982C44A22

8RBT4-300E

5982C49A20

CLE-NLC-E

9078A67G15

8NCLPT-10E-B

5981C06G01

8RBA4-40E

5982C44A10

8RBT4-30E

5982C49A09

CLE-NL-D

9078A67G03

8NCLPT-1E-A

5981C06G05

8RBA4-50E

5982C44A11

8RBT4-400E

5982C49A22

CLE-NL-E

9078A67G04

8NCLPT-2E-A

5981C06G04

8RBA4-5E

5982C44A03

8RBT4-40E

5982C49A10

CLS-700 DUMMY

591C172G01

8NCLPT-3E-B

5981C06G03

8RBA4-65E

5982C44A12

8RBT4-50E

5982C49A11

CX-DF

151D885G06

8NCLPT-5E-B

5981C06G02

8RBA4-7E

5982C44A04

8RBT4-65E

5982C49A12

CX-DL

151D885G05

8RBA2-100E

423D814A14

8RBA4-80E

5982C44A13

8RBT4-80E

5982C49A13

CXN-CLAMP

7275A85G02

8RBA2-10E

423D814A05

8RBA4-DH

5981C52G01

8RDB2-DH

309C558G05

CX-NL

151D884G08

8RBA2-125E

423D814A15

8RBA4-DH

5981C52G01

8RDB2-DH

309C558G05

DBU17-100E

5981C76G13

8RBA2-150E

423D814A16

8RBA4-GDM

9078A25G09

8RDB2-HUM

140D349G16

DBU17-100K

5981C75G14

8RBA2-15E

423D814A06

8RBA4-GDM

9078A25G09

8RDB2-HVM

140D340G16

DBU17-100SE

5981C77G09

8RBA2-175E

423D814A17

8RBA4-GNM

9078A33G17

8RDB2-SHNT

308C548G01

DBU17-10E

5981C76G03

8RBA2-200E

423D814A18

8RBA4-GNM

9078A33G17

8RDB2-UM

140D349G11

DBU17-10K

5981C75G04

8RBA2-20E

423D814A07

8RBA4-IDH

5981C52G01

8RDB2-VM

140D340G11

DBU17-125E

5981C76G14

8RBA2-25E

423D814A08

8RBA4-IDH

5981C52G01

8RDB4-DH

310C131G01

DBU17-125SE

5981C77G10

8RBA2-30E

423D814A09

8RBA4-INH

5981C53G01

8RDB4-DH

310C131G01

DBU17-12K

5981C75G05

8RBA2-40E

423D814A10

8RBA4-INH

5981C53G01

8RDB4-DH

310C131G01

DBU17-13E

5981C76G04

8RBA2-50E

423D814A11

8RBA4-INH-B

5984C17G01

8RDB4-DH

310C131G01

DBU17-140K

5981C75G15

8RBA2-65E

423D814A12

8RBA4-INH-B

5984C17G01

8RDB4-HUM

140D346G16

DBU17-150E

5981C76G15

8RBA2-80E

423D814A13

8RBA4-ISHNT

678C283G05

8RDB4-HVM

140D341G16

DBU17-150SE

5981C77G11

8RBA2-DH

309C558G01

8RBA4-ISHNT

678C283G05

8RDB4-SHNT

678C284G01

DBU17-15E

5981C76G05

8RBA2-DH

309C558G01

8RBA4-NH

677C371G01

8RDB4-SHNT

678C284G01

DBU17-15K

5981C75G06

8RBA2-GDM

9078A25G09

8RBA4-NH

677C371G01

8RDB4-UM

140D346G11

DBU17-15SE

5981C77G01

8RBA2-GDM

9078A25G09

8RBA4-PDM

9078A25G08

8RDB4-VM

140D341G11

DBU17-175E

5981C76G16

8RBA2-GNM

9078A33G17

8RBA4-PDM

9078A25G08

8RDB8-HUM

140D354G16

DBU17-175SE

5981C77G12

8RBA2-GNM

9078A33G17

8RBA4-PNM

9078A33G02

8RDB8-HVM

140D342G16

DBU17-200E

5981C76G17

8RBA2-IDH

5981C50G01

8RBA4-PNM

9078A33G02

8RDB8-UM

140D354G11

DBU17-200K

5981C75G16

8RBA2-IDH

5981C50G01

8RBA8-GNM

9078A33G23

8RDB8-VM

140D342G11

DBU17-200SE

5981C77G13

8RBA2-INH

5981C51G01

8RBA8-GNM

9078A33G23

92DBA2-100E

11A8127G33

DBU17-20E

5981C76G06

8RBA2-INH

5981C51G01

8RBA8-GNM

9078A33G23

92DBA2-10E

11A8127G24

DBU17-20K

5981C75G07

V14-A3-8

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 3—Catalog Number/Style Number Cross Reference

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

DBU17-20SE

5981C77G02

DBU27-175SE

5981C77G12

DBU38-150E

5981C76G15

RBA2-FLTR

309C024G05

DBU17-25E

5981C76G07

DBU27-200E

5981C76G17

DBU38-150SE

5981C77G11

RBA2-FLTR-1

309C024G03

DBU17-25K

5981C75G08

DBU27-200K

5981C75G16

DBU38-15E

5981C76G05

RBA4-COND

309C024G04

DBU17-25SE

5981C77G03

DBU27-200SE

5981C77G13

DBU38-15K

5981C75G06

RBA4-COND

310C197G04

DBU17-30E

5981C76G08

DBU27-20E

5981C76G06

DBU38-15SE

5981C77G01

RBA4-COND-1

310C197G06

DBU17-30K

5981C75G09

DBU27-20K

5981C75G07

DBU38-175E

5981C76G16

RBA4-FLTR

591C607G01

DBU17-30SE

5981C77G04

DBU27-20SE

5981C77G02

DBU38-175SE

5981C77G12

RBA4-FLTR-1

591C607G03

DBU17-3K

5981C75G01

DBU27-25E

5981C76G07

DBU38-200E

5981C76G17

RBA4-FLTR-HC

591C607G02

DBU17-40E

5981C76G09

DBU27-25K

5981C75G08

DBU38-200K

5981C75G16

RBA4-FLTR-HC-1

591C607G04

DBU17-40K

5981C75G10

DBU27-25SE

5981C77G03

DBU38-200SE

5981C77G13

RDB2-UL

140D349G20

DBU17-40SE

5981C77G05

DBU27-30E

5981C76G08

DBU38-20E

5981C76G06

RDB2-VL

140D340G20

DBU17-50E

5981C76G10

DBU27-30K

5981C75G09

DBU38-20K

5981C75G07

RDB4-UL

140D346G20

DBU17-50K

5981C75G11

DBU27-30SE

5981C77G04

DBU38-20SE

5981C77G02

RDB4-VL

140D341G20

DBU17-50SE

5981C77G06

DBU27-3K

5981C75G01

DBU38-25E

5981C76G07

RDB8-UL

140D354G20

DBU17-5E

5981C76G01

DBU27-40E

5981C76G09

DBU38-25K

5981C75G08

RDB8-VL

140D342G20

DBU17-65E

5981C76G11

DBU27-40K

5981C75G10

DBU38-25SE

5981C77G03

DBU17-65K

5981C75G12

DBU27-40SE

5981C77G05

DBU38-30E

5981C76G08

Spring and shunt assy. for 309C054G02
15BA2-NH

DBU17-65SE

5981C77G07

DBU27-50E

5981C76G10

DBU38-30K

5981C75G09

DBU17-6K

5981C75G02

DBU27-50K

5981C75G11

DBU38-30SE

5981C77G04

DBU17-7E

5981C76G02

DBU27-50SE

5981C77G06

DBU38-3K

5981C75G01

DBU17-80E

5981C76G12

DBU27-5E

5981C76G01

DBU38-40E

5981C76G09

DBU1780K

5981C75G03

DBU27-65E

5981C76G11

DBU38-40K

5981C75G10

DBU17-80K

5981C75G13

DBU27-65K

5981C75G12

DBU38-40SE

5981C77G05

DBU17-80SE

5981C77G08

DBU27-65SE

5981C77G07

DBU38-50E

5981C76G10

DBU17-DL-L

5982C48G02

DBU27-6K

5981C75G02

DBU38-50K

5981C75G11

DBU17-DL-R

5982C48G03

DBU27-7E

5981C76G02

DBU38-50SE

5981C77G06

DBU17-DM

5984C39G01

DBU27-80E

5981C76G12

DBU38-5E

5981C76G01

DBU17-GDM-L

5982C45G08

DBU27-80K

5981C75G13

DBU38-65E

5981C76G11

DBU17-GDM-R

5982C45G07

DBU27-80SE

5981C77G08

DBU38-65K

5981C75G12

DBU17-GNM-L

5984C25G07

DBU27-8K

5981C75G03

DBU38-65SE

5981C77G07

DBU17-GNMP-L

5984C25G01

DBU27-DL-L

5982C48G05

DBU38-6K

5981C75G02

DBU17-GNMP-R

5984C25G04

DBU27-DL-R

5982C48G06

DBU38-7E

5981C76G02

DBU17-GNM-R

5984C25G10

DBU27-DM

5984C38G01

DBU38-80E

5981C76G12

DBU17-NL-L

5984C29G01

DBU27-GDM-L

5982C45G05

DBU38-80K

5981C75G13

DBU17-NLP-L

5984C29G07

DBU27-GDM-R

5982C45G06

DBU38-80SE

5981C77G08

DBU17-NLP-R

5984C29G10

DBU27-GNM-L

5984C25G08

DBU38-8K

5981C75G03

DBU17-NL-R

5984C29G04

DBU27-GNMP-L

5984C25G02

DBU38-GNM-L

5984C25G09

DBU27-100E

5981C76G13

DBU27-GNMP-R

5984C25G05

DBU38-GNMP-L

5984C25G03

DBU27-100K

5981C75G14

DBU27-GNM-R

5984C25G11

DBU38-GNMP-R

5984C25G06

DBU27-100SE

5981C77G09

DBU27-NL-L

5984C29G02

DBU38-GNM-R

5984C25G12

DBU27-10E

5981C76G03

DBU27-NLP-L

5984C29G08

DBU38-NL-L

5984C29G03

DBU27-10K

5981C75G04

DBU27-NLP-R

5984C29G11

DBU38-NLP-L

5984C29G09

DBU27-125E

5981C76G14

DBU27-NL-R

5984C29G05

DBU38-NLP-R

5984C29G12

DBU27-125SE

5981C77G10

DBU38-100E

5981C76G13

DBU38-NL-R

5984C29G06

DBU27-12K

5981C75G05

DBU38-100K

5981C75G14

DBU-EFID

7187A11G04

DBU27-13E

5981C76G04

DBU38-100SE

5981C77G09

DBU-EFOD

7187A11G02

DBU27-140K

5981C75G15

DBU38-10E

5981C76G03

DBU-MFLR

5981C69G02

DBU27-150E

5981C76G15

DBU38-10K

5981C75G04

HANDLE ASSEMBLY

435B592G02

DBU27-150SE

5981C77G11

DBU38-125E

5981C76G14

HCL-NL

5982C19G04

DBU27-15E

5981C76G05

DBU38-125SE

5981C77G10

RBA2-COND

309C024G03

DBU27-15K

5981C75G06

DBU38-12K

5981C75G05

RBA2-COND

310C197G03

DBU27-15SE

5981C77G01

DBU38-13E

5981C76G04

RBA2-COND-1

310C197G05

DBU27-175E

5981C76G16

DBU38-140K

5981C75G15

RBA2-FLTR

309C024G03

Volume 14—Fuses

www.comoso.com

Style Number

Spring and shunt assy. for 676C878G02
15BA4-NH
Spring and shunt assy. for 309C054G01
8BA2-NH
Spring and shunt assy. for 676C878G01
8BA4-NH

CA08100016E—August 2011 www.eaton.com

V14-A3-9

Appendix 3—Catalog Number/Style Number Cross Reference

Style Number—Catalog Number Cross Reference

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

8BA4-.5

116D977A01

25BA4-80E

116D977A52

15BA2-40E

117D123A25

72DBA2-65E

11A8127G11

8BA4-5E

116D977A02

25BA4-100E

116D977A53

15BA2-50E

117D123A26

72DBA2-80E

11A8127G12

8BA4-7E

116D977A03

25BA4-125E

116D977A54

15BA2-65E

117D123A27

72DBA2-100E

11A8127G13

8BA4-10E

116D977A04

25BA4-150E

116D977A55

15BA2-80E

117D123A28

72DBA2-125E

11A8127G14

8BA4-15E

116D977A05

25BA4-200E

116D977A56

15BA2-100E

117D123A29

72DBA2-150E

11A8127G15

8BA4-20E

116D977A06

25BA4-250E

116D977A57

15BA2-125E

117D123A30

72DBA2-200E

11A8127G16

8BA4-25E

116D977A07

25BA4-300E

116D977A58

15BA2-150E

117D123A31

92DBA2-3

11A8127G21

8BA4-30E

116D977A08

38BA4-.5

116D977A61

15BA2-200E

117D123A32

92DBA2-5E

11A8127G22

8BA4-40E

116D977A09

38BA4-5E

116D977A62

25BA2-.5

117D123A33

92DBA2-7E

11A8127G23

8BA4-50E

116D977A10

38BA4-7E

116D977A63

25BA2-5E

117D123A34

92DBA2-10E

11A8127G24

8BA4-65E

116D977A11

38BA4-10E

116D977A64

25BA2-7E

117D123A35

92DBA2-15E

11A8127G25

8BA4-80E

116D977A12

38BA4-15E

116D977A65

25BA2-10E

117D123A36

92DBA2-20E

11A8127G26

8BA4-100E

116D977A13

38BA4-20E

116D977A66

25BA2-15E

117D123A37

92DBA2-25E

11A8127G27

8BA4-125E

116D977A14

38BA4-25E

116D977A67

25BA2-20E

117D123A38

92DBA2-30E

11A8127G28

8BA4-150E

116D977A15

38BA4-30E

116D977A68

25BA2-25E

117D123A39

92DBA2-40E

11A8127G29

8BA4-200E

116D977A16

38BA4-40E

116D977A69

25BA2-30E

117D123A40

92DBA2-50E

11A8127G30

8BA4-250E

116D977A17

38BA4-50E

116D977A70

25BA2-40E

117D123A41

92DBA2-65E

11A8127G31

8BA4-300E

116D977A18

38BA4-65E

116D977A71

25BA2-50E

117D123A42

92DBA2-780E

11A8127G32

8BA4-400E

116D977A19

38BA4-80E

116D977A72

25BA2-65E

117D123A43

92DBA2-100E

11A8127G33

15BA4-.5

116D977A21

38BA4-100E

116D977A73

25BA2-80E

117D123A44

92DBA2-125E

11A8127G34

15BA4-5E

116D977A22

38BA4-125E

116D977A74

25BA2-100E

117D123A45

92DBA2-150E

11A8127G35

15BA4-7E

116D977A23

38BA4-150E

116D977A75

25BA2-125E

117D123A46

92DBA2-200E

11A8127G36

15BA4-10E

116D977A24

38BA4-200E

116D977A76

25BA2-150E

117D123A47

121DBA2-3

11A8127G41

15BA4-15E

116D977A25

38BA4-250E

116D977A77

25BA2-200E

117D123A48

121DBA2-5E

11A8127G42

15BA4-20E

116D977A26

38BA4-300E

116D977A78

38BA2-.5

117D123A49

121DBA2-7E

11A8127G43

15BA4-25E

116D977A27

8BA2-.5

117D123A01

38BA2-5E

117D123A50

121DBA2-10E

11A8127G44

15BA4-30E

116D977A28

8BA2-5E

117D123A02

38BA2-7E

117D123A51

121DBA2-15E

11A8127G45

15BA4-40E

116D977A29

8BA2-7E

117D123A03

38BA2-10E

117D123A52

121DBA2-20E

11A8127G46

15BA4-50E

116D977A30

8BA2-10E

117D123A04

38BA2-15E

117D123A53

121DBA2-25E

11A8127G47

15BA4-65E

116D977A31

8BA2-15E

117D123A05

38BA2-20E

117D123A54

121DBA2-30E

11A8127G48

15BA4-80E

116D977A32

8BA2-20E

117D123A06

38BA2-25E

117D123A55

121DBA2-40E

11A8127G49

15BA4-100E

116D977A33

8BA2-25E

117D123A07

38BA2-30E

117D123A56

121DBA2-50E

11A8127G50

15BA4-125E

116D977A34

8BA2-30E

117D123A08

38BA2-40E

117D123A57

121DBA2-65E

11A8127G51

15BA4-150E

116D977A35

8BA2-40E

117D123A09

38BA2-50E

117D123A58

121DBA2-780E

11A8127G52

15BA4-200E

116D977A36

8BA2-50E

117D123A10

38BA2-65E

117D123A59

121DBA2-100E

11A8127G53

15BA4-250E

116D977A37

8BA2-65E

117D123A11

38BA2-80E

117D123A60

121DBA2-125E

11A8127G54

15BA4-300E

116D977A38

8BA2-80E

117D123A12

38BA2-100E

117D123A61

121DBA2-150E

11A8127G55

15BA4-400E

116D977A39

8BA2-100E

117D123A13

38BA2-125E

117D123A62

121DBA2-200E

11A8127G56

25BA4-.5

116D977A41

8BA2-125E

117D123A14

38BA2-150E

117D123A63

145DBA2-3

11A8127G61

25BA4-5E

116D977A42

8BA2-150E

117D123A15

38BA2-200E

117D123A64

145DBA2-5E

11A8127G62

25BA4-7E

116D977A43

8BA2-200E

117D123A16

72DBA2-5E

11A8127G02

145DBA2-7E

11A8127G63

25BA4-10E

116D977A44

15BA2-.5

117D123A17

72DBA2-7E

11A8127G03

145DBA2-10E

11A8127G64

25BA4-15E

116D977A45

15BA2-5E

117D123A18

72DBA2-10E

11A8127G04

145DBA2-15E

11A8127G65

25BA4-20E

116D977A46

15BA2-7E

117D123A19

72DBA2-15E

11A8127G05

145DBA2-20E

11A8127G66

25BA4-25E

116D977A47

15BA2-10E

117D123A20

72DBA2-20E

11A8127G06

145DBA2-25E

11A8127G67

25BA4-30E

116D977A48

15BA2-15E

117D123A21

72DBA2-25E

11A8127G07

145DBA2-30E

11A8127G68

25BA4-40E

116D977A49

15BA2-20E

117D123A22

72DBA2-30E

11A8127G08

145DBA2-40E

11A8127G69

25BA4-50E

116D977A50

15BA2-25E

117D123A23

72DBA2-40E

11A8127G09

145DBA2-50E

11A8127G70

25BA4-65E

116D977A51

15BA2-30E

117D123A24

72DBA2-50E

11A8127G10

145DBA2-65E

11A8127G71

V14-A3-10

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 3—Catalog Number/Style Number Cross Reference

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

145DBA2-780E

11A8127G72

RDB8-VL

140D342G20

5CXI-35C

151D254G26

6DSL-C1000

151D932G02

145DBA2-100E

11A8127G73

8RDB4-UM

140D346G11

5CXI-60C

151D254G29

6DSL-C1200

151D932G03

145DBA2-125E

11A8127G74

15RDB4-UM

140D346G12

5CXI-10C

151D254G31

6DSL-C1600

151D932G04

145DBA2-150E

11A8127G75

25RDB4-UM

140D346G13

5CXI-12C

151D254G32

6DSL-C2000

151D932G05

145DBA2-200E

11A8127G76

38RDB4-UM

140D346G14

8CX-3.5C

151D255G01

6DSL-D2500

151D932G09

5CLS70-32R

140D045G01

8RDB4-HUM

140D346G16

8CX-4C

151D255G02

6DSL-D3000

151D932G10

5CLS70-36R

140D045G02

15RDB4-HUM

140D346G17

8CX-7C

151D255G03

5ACLS-9R

151D933G01

5CLS70-24R

140D045G03

25RDB4-HUM

140D346G18

8CX-15C

151D255G06

5ACLS-12R

151D933G02

5CLS70-12R

140D045G04

38RDB4-HUM

140D346G19

8CX-35C

151D255G09

5ACLS-18R

151D933G03

5CLS70-44R

140D045G05

RDB4-UL

140D346G20

8CX-10C

151D255G11

5ACLS-24R

151D933G04

5CLS70-18R

140D045G06

8RDB2-UM

140D349G11

8CX-12C

151D255G12

5CLS-9R

151D961G01

6DSL-A150

140D316G01

15RDB2-UM

140D349G12

8CXI-3.5C

151D255G21

5CLS-12R

151D961G02

6DSL-A200

140D316G02

15RDB2-UM

140D349G13

8CXI-4C

151D255G22

5CLS-18R

151D961G03

6DSL-A250

140D316G03

38RDB2-UM

140D349G14

8CXI-7C

151D255G23

5CLS-24R

151D961G04

6DSL-A300

140D316G04

8RDB2-HUM

140D349G16

8CXI-15C

151D255G26

5HCLS-9R

151D962G01

6DSL-A400

140D316G05

15RDB2-HUM

140D349G17

8CXI-35C

151D255G29

5HCLS-12R

151D962G02

6DSL-A600

140D316G06

25RDB2-HUM

140D349G18

8CXI-10C

151D255G31

5HCLS-18R

151D962G03

6DSL-A800

140D316G07

38RDB2-HUM

140D349G19

8CXI-12C

151D255G32

5HCLS-24R

151D962G04

6DSL-B1200

140D316G10

RDB2-UL

140D349G20

8CLS-15

151D256G01

8ACLS-2R

151D963G01

6DSL-B1600

140D316G11

8RDB8-UM

140D354G11

8CLS-30

151D256G02

8ACLS-3R

151D963G02

6DSL-B3000

140D316G12

15RDB8-UM

140D354G12

8CLS-60

151D256G03

8ACLS-4R

151D963G03

4NPL-1875

140D318G01

25RDB8-UM

140D354G13

8CLS-70

151D256G04

8ACLS-5R

151D963G04

4NPL-2825

140D318G02

38RDB8-UM

140D354G14

8CLS-90

151D256G05

8ACLS-6R

151D963G05

4NPL-900

140D318G04

8RDB8-HUM

140D354G16

8CLS-110

151D256G06

7ACLS-9R

151D963G06

4NPL-1300

140D318G05

15RDB8-HUM

140D354G17

8CLS-125

151D256G07

7ACLS-12R

151D963G07

4NPL-3000

140D318G06

25RDB8-HUM

140D354G18

8CLS-150

151D256G11

7ACLS18R

151D963G10

4NPL-2000

140D318G07

38RDB8-HUM

140D354G19

8CLS-200

151D256G12

7ACLS-24R

151D963G11

8RDB2-VM

140D340G11

RDB8-UL

140D354G20

8CLS-225

151D256G13

38DBA2-5E

18A7330G13

15RDB2-VM

140D340G12

4ACLS-26R

151D207G01

5CLS75-36R

151D257G01

38DBA2-7E

18A7330G14

25RDB2-VM

140D340G13

5HCLS-30

151D240G01

5CLS75-32R

151D257G02

38DBA2-10E

18A7330G15

38RDB2-VM

140D340G14

5HCLS-2R

151D240G02

151D257G03

151D257G03

38DBA2-15E

18A7330G16

8RDB2-HVM

140D340G16

5HCLS-3R

151D240G03

151D257G04

151D257G04

38DBA2-20E

18A7330G17

15RDB2-HVM

140D340G17

5HCLS-4R

151D240G04

5CLS75-24R

151D257G05

38DBA2-25E

18A7330G18

25RDB2-HVM

140D340G18

5HCLS-5R

151D240G05

15CX-4C

151D883G01

38DBA2-30E

18A7330G19

38RDB2-HVM

140D340G19

5HCLS-6R

151D240G06

15CX-7C

151D883G02

38DBA2-40E

18A7330G20

RDB2-VL

140D340G20

5CLS-30

151D241G01

15CX-15C

151D883G05

38DBA2-50E

18A7330G21

8RDB4-VM

140D341G11

5CLS-2R

151D241G02

15CX-10C

151D883G11

38DBA2-65E

18A7330G22

15RDB4-VM

140D341G12

5CLS-3R

151D241G03

15CX-3C

151D883G12

38DBA2-780E

18A7330G23

25RDB4-VM

140D341G13

5CLS-4R

151D241G04

15CXI-4C

151D883G21

38DBA2-100E

18A7330G24

38RDB4-VM

140D341G14

5CLS-5R

151D241G05

15CXI-7C

151D883G22

38DBA2-125E

18A7330G25

8RDB4-HVM

140D341G16

5CLS-6R

151D241G06

15CXI-15C

151D883G25

38DBA2-150E

18A7330G26

15RDB4-HVM

140D341G17

4CX-60C

151D253G06

15CXI-10C

151D883G31

38DBA2-200E

18A7330G27

25RDB4-HVM

140D341G18

4CX-80C

151D253G08

15CXI-3C

151D883g32

48DBA2-5E

18A7330G33

38RDB4-HVM

140D341G19

4CXI-60C

151D253G26

5CX-GNM-G

151D884G01

48DBA2-7E

18A7330G34

RDB4-VL

140D341G20

4CXI-80C

151D253G28

8CX-GNM-G

151D884G02

48DBA2-10E

18A7330G35

8RDB8-VM

140D342G11

5CX-25C

151D254G03

15CX-GNM-G

151D884G03

48DBA2-15E

18A7330G36

15RDB8-VM

140D342G12

5CX-21C

151D254G04

CX-NL

151D884G08

48DBA2-20E

18A7330G37

25RDB8-VM

140D342G13

5CX-35C

151D254G06

5CX-GDM-G

151D885G01

48DBA2-25E

18A7330G38

38RDB8-VM

140D342G14

5CX-60C

151D254G09

8CX-GDM-G

151D885G02

48DBA2-30E

18A7330G39

8RDB8-HVM

140D342G16

5CX-10C

151D254G11

15CX-GDM-G

151D885G03

48DBA2-40E

18A7330G40

15RDB8-HVM

140D342G17

5CX-12C

151D254G12

CX-DL

151D885G05

48DBA2-50E

18A7330G41

25RDB8-HVM

140D342G18

5CXI-25C

151D254G23

CX-DF

151D885G06

48DBA2-65E

18A7330G42

38RDB8-HVM

140D342G19

5CXI-21C

151D254G24

6DSL-C800

151D932G01

48DBA2-780E

18A7330G43

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-A3-11

Appendix 3—Catalog Number/Style Number Cross Reference

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

48DBA2-100E

18A7330G44

25RDB4-DH

310C131G03

25RBA2-150E

423D814A56

25RBT2-30E

449D671A49

48DBA2-125E

18A7330G45

25RDB4-DH

310C131G03

25RBA2-175E

423D814A57

25RBT2-40E

449D671A50

48DBA2-150E

18A7330G46

38RDB4-DH

310C131G04

25RBA2-200E

423D814A58

25RBT2-50E

449D671A51

48DBA2-200E

18A7330G47

38RDB4-DH

310C131G04

38RBA2-10E

423D814A65

25RBT2-65E

449D671A52

38DBA2-.5

22A6782G04

38RDB4-DH

310C131G04

38RBA2-15E

423D814A66

25RBT2-80E

449D671A53

48DBA2-.5

22A6782G05

38RDB4-DH

310C131G04

38RBA2-20E

423D814A67

25RBT2-100E

449D671A54

72DBA2-.5

22A6782G06

8BA4-NH

310C196G01

38RBA2-25E

423D814A68

25RBT2-125E

449D671A55

5LCLS-18R

304C463G03

15BA4-NH

310C196G02

38RBA2-30E

423D814A69

25RBT2-150E

449D671A56

5LCLS-24R

304C463G04

RBA2-COND

310C197G03

38RBA2-40E

423D814A70

25RBT2-200E

449D671A58

8RDB2-SHNT

308C548G01

RBA4-COND

310C197G04

38RBA2-50E

423D814A71

38RBT2-20E

449D671A67

15RDB2-SHNT

308C548G02

RBA2-COND-1

310C197G05

38RBA2-65E

423D814A72

38RBT2-25E

449D671A68

25RDB2-SHNT

308C548G03

RBA4-COND-1

310C197G06

38RBA2-80E

423D814A73

38RBT2-30E

449D671A69

38RDB2-SHNT

308C548G04

8BA2-NH

310C198G01

38RBA2-100E

423D814A74

38RBT2-40E

449D671A70

RBA2-COND

309C024G03

15BA2-NH

310C198G02

38RBA2-125E

423D814A75

38RBT2-50E

449D671A71

RBA2-FLTR

309C024G03

8RBA2-10E

423D814A05

38RBA2-150E

423D814A76

38RBT2-65E

449D671A72

RBA2-FLTR-1

309C024G03

8RBA2-15E

423D814A06

38RBA2-175E

423D814A77

38RBT2-80E

449D671A73

RBA4-COND

309C024G04

8RBA2-20E

423D814A07

38RBA2-200E

423D814A78

38RBT2-100E

449D671A74

RBA2-FLTR

309C024G05

8RBA2-25E

423D814A08

HANDLE ASSEMBLY 435B592G02

38RBT2-125E

449D671A75

Spring and shunt
assy. for 8BA2-NH

309C054G01

8RBA2-30E

423D814A09

15CLE2-80E

439D482G04

38RBT2-150E

449D671A76

8RBA2-40E

423D814A10

15CLE2-100E

439D482G05

38RBT2-200E

449D671A78

8RBA2-50E

423D814A11

15CLE2-125X

439D482G06

2CLE-30E

449D797G02

8RBA2-65E

423D814A12

5CLE-750E

449D595G01

2CLE-50E

449D797G03

8RBA2-80E

423D814A13

5CLE-600E

449D595G02

2CLE-65E

449D797G04

8RBA2-100E

423D814A14

5ACLS-30

449D597G01

2CLE-80E

449D797G05

8RBA2-125E

423D814A15

5ACLS-2R

449D597G02

2CLE-100E

449D797G06

8RBA2-150E

423D814A16

5ACLS-3R

449D597G03

2CLE-125E

449D797G07

8RBA2-175E

423D814A17

5ACLS-4R

449D597G04

2CLE-150E

449D797G08

8RBA2-200E

423D814A18

5ACLS-5R

449D597G05

2CLE-200E

449D797G09

15RBA2-10E

423D814A25

5ACLS-6R

449D597G06

2CLE-225E

449D797G10

15RBA2-15E

423D814A26

8RBT2-20E

449D671A07

2CLE-10E

449D797G11

15RBA2-20E

423D814A27

8RBT2-25E

449D671A08

2CLE-25E

449D797G12

15RBA2-25E

423D814A28

8RBT2-30E

449D671A09

2CLE-250E

449D797G13

15RBA2-30E

423D814A29

8RBT2-40E

449D671A10

2CLE-300E

449D797G14

15RBA2-40E

423D814A30

8RBT2-50E

449D671A11

2CLE-350X

449D797G15

15RBA2-50E

423D814A31

8RBT2-65E

449D671A12

2CLE-400X

449D797G17

15RBA2-65E

423D814A32

8RBT2-80E

449D671A13

2CLE-450X

449D797G18

15RBA2-80E

423D814A33

8RBT2-100E

449D671A14

38DBA2-3

505D420G07

15RBA2-100E

423D814A34

8RBT2-125E

449D671A15

48DBA2-3

505D420G08

15RBA2-125E

423D814A35

8RBT2-150E

449D671A16

72DBA2-3

505D420G09

15RBA2-150E

423D814A36

8RBT2-200E

449D671A18

2ACLS-25

591C142G01

15RBA2-175E

423D814A37

15RBT2-20E

449D671A27

2ACLS-2R

591C142G02

15RBA2-200E

423D814A38

15RBT2-25E

449D671A28

2ACLS-3R

591C142G03

25RBA2-10E

423D814A45

15RBT2-30E

449D671A29

2ACLS-4R

591C142G04

25RBA2-15E

423D814A46

15RBT2-40E

449D671A30

2ACLS-5R

591C142G05

25RBA2-20E

423D814A47

15RBT2-50E

449D671A31

2ACLS-6R

591C142G06

25RBA2-25E

423D814A48

15RBT2-65E

449D671A32

2ACLS-9R

591C142G07

25RBA2-30E

423D814A49

15RBT2-80E

449D671A33

2ACLS-12R

591C142G08

25RBA2-40E

423D814A50

15RBT2-100E

449D671A34

2ACLS-18R

591C143G01

25RBA2-50E

423D814A51

15RBT2-125E

449D671A35

2ACLS-24R

591C143G02

25RBA2-65E

423D814A52

15RBT2-150E

449D671A36

2HCLS-25

591C155G01

25RBA2-80E

423D814A53

15RBT2-200E

449D671A38

2HCLS-2R

591C155G02

25RBA2-100E

423D814A54

25RBT2-20E

449D671A47

2HCLS-3R

591C155G03

25RBA2-125E

423D814A55

25RBT2-25E

449D671A48

2HCLS-4R

591C155G04

Spring and shunt
309C054G02
assy. for 15BA2-NH
8RBA2-ISHNT
15RBA2-ISHNT
25RBA2-ISHNT

309C548G09
309C548G10
309C548G11

38RBA2-ISHNT

309C548G12

8RBA2-DH

309C558G01

8RBA2-DH
15RBA2-DH
15RBA2-DH
25RBA2-DH
38RBA2-DH

309C558G01
309C558G02
309C558G02
309C558G03
309C558G04

8RDB2-DH

309C558G05

8RDB2-DH

309C558G05

15RDB2-DH
15RDB2-DH
25RDB2-DH
25RDB2-DH
38RDB2-DH
38RDB2-DH
15RBA4-DH

309C558G06
309C558G06
309C558G07
309C558G07
309C558G08
309C558G08
309C797G02

15RBA4-DH

309C797G02

25RBA4-DH

309C797G03

38RBA4-DH
8RDB4-DH
8RDB4-DH
8RDB4-DH

309C797G04
310C131G01
310C131G01
310C131G01

8RDB4-DH

310C131G01

15RDB4-DH

310C131G02

15RDB4-DH
15RDB4-DH

310C131G02
310C131G02

15RDB4-DH

310C131G02

25RDB4-DH

310C131G03

25RDB4-DH

V14-A3-12

310C131G03

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 3—Catalog Number/Style Number Cross Reference

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

2HCLS-5R

591C155G05

5CXI-18C

5978C70G21

15DBA1-80E

5980C15G33

48DBA1-125E

5980C17G15

2HCLS-6R

591C155G06

5CXI-20C

5978C70G22

15DBA1-100E

5980C15G34

48DBA1-150E

5980C17G16

2HCLS-9R

591C155G07

5CXI-30C

5978C70G24

15DBA1-125E

5980C15G35

48DBA1-200E

5980C17G17

2HCLS-12R

591C155G08

5CXI-40C

5978C70G25

15DBA1-150E

5980C15G36

72DBA1-0.5

5980C17G21

2HCLS-18R

591C157G01

5CXI-50C

5978C70G26

15DBA1-200E

5980C15G37

72DBA1-3

5980C17G22

2HCLS-24R

591C157G02

5CXI-65C

5978C70G27

25DBA1-0.5

5980C16G01

72DBA1-5E

5980C17G23

CLS-700 DUMMY

591C172G01

5CXI-75C

5978C70G28

25DBA1-3

5980C16G02

72DBA1-7E

5980C17G24

8CLT-12C

591C273G03

8CX-18C

5978C72G01

25DBA1-5E

5980C16G03

72DBA1-10E

5980C17G25

15CLE3-175E/200X

591C376G01

8CX-20C

5978C72G02

25DBA1-7E

5980C16G04

72DBA1-15E

5980C17G26

15CLE3-150E

591C376G02

8CX-25C

5978C72G03

25DBA1-10E

5980C16G05

72DBA1-20E

5980C17G27

RBA4-FLTR

591C607G01

8CX-30C

5978C72G04

25DBA1-15E

5980C16G06

72DBA1-25E

5980C17G28

RBA4-FLTR-HC

591C607G02

8CX-40C

5978C72G05

25DBA1-20E

5980C16G07

72DBA1-30E

5980C17G29

RBA4-FLTR-1

591C607G03

8CXI-18C

5978C72G21

25DBA1-25E

5980C16G08

72DBA1-40E

5980C17G30

RBA4-FLTR-HC-1

591C607G04

8CXI-20C

5978C72G22

25DBA1-30E

5980C16G09

72DBA1-50E

5980C17G31

2CLS-25

591C812G01

8CXI-25C

5978C72G23

25DBA1-40E

5980C16G10

72DBA1-65E

5980C17G32

2CLS-2R

591C812G02

8CXI-30C

5978C72G24

25DBA1-50E

5980C16G11

72DBA1-80E

5980C17G33

2CLS-3R

591C812G03

8CXI-40C

5978C72G25

25DBA1-65E

5980C16G12

72DBA1-100E

5980C17G34

2CLS-4R

591C812G04

7CLS70-24R

5979C91G01

25DBA1-80E

5980C16G13

72DBA1-125E

5980C17G35

2CLS-5R

591C812G05

7CLS70-36R

5979C91G02

25DBA1-100E

5980C16G14

72DBA1-150E

5980C17G36

2CLS-6R

591C812G06

6DSL-E2500

5980C01G01

25DBA1-125E

5980C16G15

72DBA1-200E

5980C17G37

2CLS-9R

591C812G07

6DSL-E3000

5980C01G02

25DBA1-150E

5980C16G16

15CX-18C

5980C19G01

2CLS-12R

591C812G08

6DSL-E4000

5980C01G03

25DBA1-200E

5980C16G17

15CX-20C

5980C19G02

2CLS-18R

591C813G01

6DSL-F5000

5980C01G04

38DBA1-0.5

5980C16G21

15CX-25C

5980C19G03

2CLS-24R

591C813G02

7CLS70-44R

5980C03G01

38DBA1-3

5980C16G22

15CX-30C

5980C19G04

4CX-18C

5978C62G01

8DBA1-0.5

5980C15G01

38DBA1-5E

5980C16G23

15CX-40C

5980C19G05

4CX-25C

5978C62G02

8DBA1-3

5980C15G02

38DBA1-7E

5980C16G24

15CX-6C

5980C19G06

4CX-35C

5978C62G03

8DBA1-5E

5980C15G03

38DBA1-10E

5980C16G25

15CX-12C

5980C19G07

8CX-4.5C

5978C62G04

8DBA1-7E

5980C15G04

38DBA1-15E

5980C16G26

15CX-8C

5980C19G07

8CX-6C

5978C62G05

8DBA1-10E

5980C15G05

38DBA1-20E

5980C16G27

15CXI-18C

5980C19G21

8CX-8C

5978C62G06

8DBA1-15E

5980C15G06

38DBA1-25E

5980C16G28

15CXI-20C

5980C19G22

4CXI-18C

5978C62G21

8DBA1-20E

5980C15G07

38DBA1-30E

5980C16G29

15CXI-25C

5980C19G23

4CXI-25C

5978C62G22

8DBA1-25E

5980C15G08

38DBA1-40E

5980C16G30

15CXI-30C

5980C19G24

4CXI-35C

5978C62G23

8DBA1-30E

5980C15G09

38DBA1-50E

5980C16G31

15CXI-40C

5980C19G25

8CXI-4.5C

5978C62G24

8DBA1-40E

5980C15G10

38DBA1-65E

5980C16G32

15CXI-6C

5980C19G26

8CXI-6C

5978C62G25

8DBA1-50E

5980C15G11

38DBA1-80E

5980C16G33

15CXI-12C

5980C19G27

8CXI-8C

5978C62G26

8DBA1-65E

5980C15G12

38DBA1-100E

5980C16G34

15CXI-8C

5980C19G27

4CX-45C

5978C66G01

8DBA1-80E

5980C15G13

38DBA1-125E

5980C16G35

5HLE-PDM-D

5981C03G01

4CX-50C

5978C66G02

8DBA1-100E

5980C15G14

38DBA1-150E

5980C16G36

8HLE-PDM-D

5981C03G02

4CX-65C

5978C66G03

8DBA1-125E

5980C15G15

38DBA1-200E

5980C16G37

15HLE-PDM-D

5981C03G03

4CX-75C

5978C66G04

8DBA1-150E

5980C15G16

48DBA1-0.5

5980C17G01

5HLE-GDM-D

5981C03G04

4CX-100C

5978C66G05

8DBA1-200E

5980C15G17

48DBA1-3

5980C17G02

8HLE-GDM-D

5981C03G05

4CXI-45C

5978C66G21

15DBA1-0.5

5980C15G21

48DBA1-5E

5980C17G03

15HLE-GDM-D

5981C03G06

4CXI-50C

5978C66G22

15DBA1-3

5980C15G22

48DBA1-7E

5980C17G04

5HLE-PNM-D

5981C03G07

4CXI-65C

5978C66G23

15DBA1-5E

5980C15G23

48DBA1-10E

5980C17G05

8HLE-PNM-D

5981C03G08

4CXI-75C

5978C66G24

15DBA1-7E

5980C15G24

48DBA1-15E

5980C17G06

15HLE-PNM-D

5981C03G09

4CXI-100C

5978C66G25

15DBA1-10E

5980C15G25

48DBA1-20E

5980C17G07

5HLE-GNM-D

5981C03G10

5CX-18C

5978C70G01

15DBA1-15E

5980C15G26

48DBA1-25E

5980C17G08

8HLE-GNM-D

5981C03G11

5CX-20C

5978C70G02

15DBA1-20E

5980C15G27

48DBA1-30E

5980C17G09

15HLE-GNM-D

5981C03G12

5CX-30C

5978C70G04

15DBA1-25E

5980C15G28

48DBA1-40E

5980C17G10

5HLE-PDM-E

5981C03G13

5CX-40C

5978C70G05

15DBA1-30E

5980C15G29

48DBA1-50E

5980C17G11

8HLE-GDM-E

5981C03G14

5CX-50C

5978C70G06

15DBA1-40E

5980C15G30

48DBA1-65E

5980C17G12

8HLE-PDM-E

5981C03G14

5CX-65C

5978C70G07

15DBA1-50E

5980C15G31

48DBA1-80E

5980C17G13

15HLE-PDM-E

5981C03G15

5CX-75C

5978C70G08

15DBA1-65E

5980C15G32

48DBA1-100E

5980C17G14

5HLE-GDM-E

5981C03G16

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A3-13

Appendix 3—Catalog Number/Style Number Cross Reference

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

15HLE-GDM-E

5981C03G18

15HLE-100E

5981C18G09

15HLE-25E

5981C32G04

25RBA2-INH

5981C51G03

5HLE-PNM-E

5981C03G19

15HLE-125E

5981C18G10

15HLE-30E

5981C32G05

38RBA2-INH

5981C51G04

8HLE-PNM-E

5981C03G20

15CLE-40E

5981C19G04

15CLE-10E

5981C33G01

8RBA4-DH

5981C52G01

15HLE-PNM-E

5981C03G21

15CLE-50E

5981C19G05

15CLE-15E-D

5981C33G02

8RBA4-DH

5981C52G01

5HLE-GNM-E

5981C03G22

15CLE-65E

5981C19G06

15CLE-20E-D

5981C33G03

8RBA4-IDH

5981C52G01

8HLE-GNM-E

5981C03G23

15CLE-80E

5981C19G07

15CLE-25E-D

5981C33G04

8RBA4-IDH

5981C52G01

15HLE-GNM-E

5981C03G24

15CLE-100E

5981C19G08

15CLE-30E

5981C33G05

15RBA4-IDH

5981C52G02

5NCLPT-10E-A

5981C05G01

15CLE-125E

5981C19G09

5AHLE-10E

5981C46G01

15RBA4-IDH

5981C52G02

5NCLPT-5E-A

5981C05G02

15CLE-150E

5981C19G10

5AHLE-15E

5981C46G02

25RBA4-IDH

5981C52G03

5NCLPT-3E-A

5981C05G03

8CLE-200E

5981C21G01

5AHLE-20E

5981C46G03

38RBA4-IDH

5981C52G04

5NCLPT-2E-A

5981C05G04

8CLE-250E

5981C21G02

5AHLE-25E

5981C46G04

8RBA4-INH

5981C53G01

5NCLPT-1E-A

5981C05G05

8CLE-300E

5981C21G03

5AHLE-30E

5981C46G05

8RBA4-INH

5981C53G01

5NCLPT-0.5E-A

5981C05G06

8CLE-350E

5981C21G04

5AHLE-40E

5981C46G06

15RBA4-INH

5981C53G02

8NCLPT-10E-B

5981C06G01

8HLE-200E

5981C22G01

5AHLE-50E

5981C46G07

15RBA4-INH

5981C53G02

8NCLPT-5E-B

5981C06G02

8HLE-250E

5981C22G02

5AHLE-65E

5981C46G08

25RBA4-INH

5981C53G03

8NCLPT-3E-B

5981C06G03

8HLE-300E

5981C22G03

5AHLE-80E

5981C46G09

38RBA4-INH

5981C53G04

8NCLPT-2E-A

5981C06G04

8HLE-350E

5981C22G04

5AHLE-100E

5981C46G10

8RBA8-INH

5981C54G01

8NCLPT-1E-A

5981C06G05

15HLE-150E

5981C24G01

5AHLE-125E

5981C46G11

8RBA8-INH

5981C54G01

8NCLPT-0.5E-A

5981C06G06

15HLE-175E

5981C24G02

5AHLE-150E

5981C46G12

15RBA8-INH

5981C54G02

15NCLPT-10E-B

5981C07G01

15HLE-200E

5981C24G03

5AHLE-175E

5981C46G13

15RBA8-INH

5981C54G02

15NCLPT-5E-B

5981C07G02

15HLE-250E

5981C24G04

5AHLE-200E

5981C46G14

25RBA8-INH

5981C54G03

15NCLPT-3E-B

5981C07G03

15CLE-175E

5981C25G01

5AHLE-250E

5981C46G15

38RBA8-INH

5981C54G04

15NCLPT-20.5E-A

5981C07G04

15CLE-200E

5981C25G02

5AHLE-300E

5981C46G16

5BHCL-750E

5981C58G01

15NCLPT-1E-A

5981C07G05

15CLE-250E

5981C25G03

5AHLE-350E

5981C46G17

5BHCL-900E

5981C58G02

15NCLPT-0.5E-A

5981C07G06

15CLE-300E

5981C25G04

5AHLE-400E

5981C46G18

15HCL-250E

5981C61G01

8HLE-40E

5981C16G04

5HLE-10E

5981C28G01

5AHLE-450E

5981C46G19

15HCL-300E

5981C61G02

8HLE-50E

5981C16G05

5HLE-15E

5981C28G02

8AHLE-10E

5981C47G01

15HCL-200E

5981C61G03

8HLE-65E

5981C16G06

5HLE-20E

5981C28G03

8AHLE-15E

5981C47G02

15HCL-150E

5981C61G04

8HLE-80E

5981C16G07

5HLE-25E

5981C28G04

8AHLE-20E

5981C47G03

5HCL-500E

5981C62G01

8HLE-100E

5981C16G08

5HLE-30E

5981C28G05

8AHLE-25E

5981C47G04

5HCL-600E

5981C62G02

8HLE-125E

5981C16G09

5CLE-10E-D

5981C29G01

8AHLE-30E

5981C47G05

5HCL-450E

5981C62G03

8HLE-150E

5981C16G10

5HCL-10E

5981C29G01

8AHLE-40E

5981C47G06

5HCL-400E

5981C62G04

8HLE-175E

5981C16G11

5CLE-15E-D

5981C29G02

8AHLE-50E

5981C47G07

5HCL-300E

5981C62G05

15RBA4-INH-B

5981C17G02

5HCL-15E

5981C29G02

8AHLE-65E

5981C47G08

5HCL-250E

5981C62G06

15RBA4-INH-B

5981C17G02

5CLE-20E-D

5981C29G03

8AHLE-80E

5981C47G09

5HCL-200E

5981C62G07

25RBA4-INH-B

5981C17G03

5HCL-20E

5981C29G03

8AHLE-100E

5981C47G10

5BHCL-600E

5981C62G08

38RBA4-INH-B

5981C17G04

5CLE-25E-D

5981C29G04

8AHLE-125E

5981C47G11

5BHCL-500E

5981C62G09

8CLE-40E

5981C17G04

5HCL-25E

5981C29G04

8AHLE-150E

5981C47G12

5BHCL-450E

5981C62G10

8CLE-50E

5981C17G05

5CLE-30E

5981C29G05

8AHLE-175E

5981C47G13

5BHCL-400E

5981C62G11

8CLE-65E

5981C17G06

5HCL-30E

5981C29G05

8AHLE-200E

5981C47G14

5HLE-40E

5981C64G01

8CLE-80E

5981C17G07

8HLE-10E

5981C30G01

8AHLE-250E

5981C47G15

5HLE-50E

5981C64G02

8CLE-100E

5981C17G08

8HLE-15E

5981C30G02

8AHLE-300E

5981C47G16

5HLE-65E

5981C64G03

8CLE-125E

5981C17G09

8HLE-20E

5981C30G03

8AHLE-350E

5981C47G17

5HLE-80E

5981C64G04

8CLE-150E

5981C17G10

8HLE-25E

5981C30G04

8RBA2-IDH

5981C50G01

5HLE-100E

5981C64G05

8CLE-175E

5981C17G11

8HLE-30E

5981C30G05

8RBA2-IDH

5981C50G01

5HLE-125E

5981C64G06

15RBA2-INH-B

5981C18G02

8CLE-10E

5981C31G01

15RBA2-IDH

5981C50G02

5HLE-150E

5981C64G07

15RBA2-INH-B

5981C18G02

8CLE-15E-D

5981C31G02

15RBA2-IDH

5981C50G02

5HLE-175E

5981C64G08

25RBA2-INH-B

5981C18G03

8CLE-20E-D

5981C31G03

25RBA2-IDH

5981C50G03

5HLE-200E

5981C64G09

38RBA2-INH-B

5981C18G04

8CLE-25E-D

5981C31G04

38RBA2-IDH

5981C50G04

5HLE-250E

5981C64G10

15HLE-40E

5981C18G05

8CLE-30E

5981C31G05

8RBA2-INH

5981C51G01

5CLE-40E

5981C65G01

15HLE-50E

5981C18G06

15HLE-10E

5981C32G01

8RBA2-INH

5981C51G01

5CLE-50E

5981C65G02

15HLE-65E

5981C18G07

15HLE-15E

5981C32G02

15RBA2-INH

5981C51G02

5CLE-65E

5981C65G03

15HLE-80E

5981C18G08

15HLE-20E

5981C32G03

15RBA2-INH

5981C51G02

5CLE-80E

5981C65G04

V14-A3-14

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 3—Catalog Number/Style Number Cross Reference

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

5CLE-100E

5981C65G05

DBU17-40K

5981C75G10

DBU38-65E

5981C76G11

DBU27-175SE

5981C77G12

5CLE-125E

5981C65G06

DBU27-40K

5981C75G10

DBU17-80E

5981C76G12

DBU38-175SE

5981C77G12

5HCL-40E

5981C65G06

DBU38-40K

5981C75G10

DBU27-80E

5981C76G12

DBU17-200SE

5981C77G13

5CLE-150E

5981C65G07

DBU17-50K

5981C75G11

DBU38-80E

5981C76G12

DBU27-200SE

5981C77G13

5HCL-50E

5981C65G07

DBU27-50K

5981C75G11

DBU17-100E

5981C76G13

DBU38-200SE

5981C77G13

5CLE-175E

5981C65G08

DBU38-50K

5981C75G11

DBU27-100E

5981C76G13

5CLS70-9R

5981C81G01

5HCL-65E

5981C65G08

DBU17-65K

5981C75G12

DBU38-100E

5981C76G13

5CLS70-5R

5981C81G03

5CLE-200E

5981C65G09

DBU27-65K

5981C75G12

DBU17-125E

5981C76G14

5CLS70-4R

5981C81G04

5HCL-80E

5981C65G09

DBU38-65K

5981C75G12

DBU27-125E

5981C76G14

5CLS70-3R

5981C81G05

5CLE-250E

5981C65G10

DBU17-80K

5981C75G13

DBU38-125E

5981C76G14

5CLS70-2R

5981C81G06

5HCL-100E

5981C65G10

DBU27-80K

5981C75G13

DBU17-150E

5981C76G15

5CLS70-6R

5981C81G12

5HCL-125E

5981C65G11

DBU38-80K

5981C75G13

DBU27-150E

5981C76G15

8CLS-2R

5982C01G01

5HCL-150E

5981C65G12

DBU17-100K

5981C75G14

DBU38-150E

5981C76G15

8CLS-3R

5982C01G02

5HLE-300E

5981C66G01

DBU27-100K

5981C75G14

DBU17-175E

5981C76G16

8CLS-4R

5982C01G03

5HLE-350E

5981C66G02

DBU38-100K

5981C75G14

DBU27-175E

5981C76G16

8CLS-5R

5982C01G04

5HLE-400E

5981C66G03

DBU17-140K

5981C75G15

DBU38-175E

5981C76G16

8CLS-6R

5982C01G05

5HLE-450E

5981C66G04

DBU27-140K

5981C75G15

DBU17-200E

5981C76G17

7CLS-9R

5982C01G06

5CLE-300E

5981C67G01

DBU38-140K

5981C75G15

DBU27-200E

5981C76G17

7CLS-12R

5982C01G07

5CLE-350E

5981C67G02

DBU17-200K

5981C75G16

DBU38-200E

5981C76G17

7CLS-18R

5982C01G10

5CLE-400E

5981C67G03

DBU27-200K

5981C75G16

DBU17-15SE

5981C77G01

7CLS-24R

5982C01G11

5CLE-450E

5981C67G04

DBU38-200K

5981C75G16

DBU27-15SE

5981C77G01

HCL-NL

5982C19G04

15HCL-65E

5981C68G04

DBU17-5E

5981C76G01

DBU38-15SE

5981C77G01

5BCLS-30

5982C31G01

15HCL-80E

5981C68G05

DBU27-5E

5981C76G01

DBU17-20SE

5981C77G02

5BCLS-2R

5982C31G02

15HCL-100E

5981C68G06

DBU38-5E

5981C76G01

DBU27-20SE

5981C77G02

5BCLS-3R

5982C31G03

15HCL-125E

5981C68G07

DBU17-7E

5981C76G02

DBU38-20SE

5981C77G02

5BCLS-4R

5982C31G04

DBU-MFLR

5981C69G02

DBU27-7E

5981C76G02

DBU17-25SE

5981C77G03

5BCLS-5R

5982C31G05

DBU17-3K

5981C75G01

DBU38-7E

5981C76G02

DBU27-25SE

5981C77G03

5BCLS-6R

5982C31G06

DBU27-3K

5981C75G01

DBU17-10E

5981C76G03

DBU38-25SE

5981C77G03

5BCLS-9R

5982C31G07

DBU38-3K

5981C75G01

DBU27-10E

5981C76G03

DBU17-30SE

5981C77G04

5BCLS-12R

5982C31G08

DBU17-6K

5981C75G02

DBU38-10E

5981C76G03

DBU27-30SE

5981C77G04

5BCLS-18R

5982C32G01

DBU27-6K

5981C75G02

DBU17-13E

5981C76G04

DBU38-30SE

5981C77G04

5BCLS-24R

5982C32G02

DBU38-6K

5981C75G02

DBU27-13E

5981C76G04

DBU17-40SE

5981C77G05

4BCLS-26R

5982C32G03

DBU1780K

5981C75G03

DBU38-13E

5981C76G04

DBU27-40SE

5981C77G05

15HCL-10E

5982C34G01

DBU27-8K

5981C75G03

DBU17-15E

5981C76G05

DBU38-40SE

5981C77G05

15HCL-15E

5982C34G02

DBU38-8K

5981C75G03

DBU27-15E

5981C76G05

DBU17-50SE

5981C77G06

15HCL-20E

5982C34G03

DBU17-10K

5981C75G04

DBU38-15E

5981C76G05

DBU27-50SE

5981C77G06

15HCL-25E

5982C34G04

DBU27-10K

5981C75G04

DBU17-20E

5981C76G06

DBU38-50SE

5981C77G06

15HCL-30E

5982C34G05

DBU38-10K

5981C75G04

DBU27-20E

5981C76G06

DBU17-65SE

5981C77G07

15HCL-40E

5982C34G06

DBU17-12K

5981C75G05

DBU38-20E

5981C76G06

DBU27-65SE

5981C77G07

15HCL-50E

5982C34G07

DBU27-12K

5981C75G05

DBU17-25E

5981C76G07

DBU38-65SE

5981C77G07

7BCLS-2R

5982C36G01

DBU38-12K

5981C75G05

DBU27-25E

5981C76G07

DBU17-80SE

5981C77G08

7BCLS-3R

5982C36G02

DBU17-15K

5981C75G06

DBU38-25E

5981C76G07

DBU27-80SE

5981C77G08

7BCLS-4R

5982C36G03

DBU27-15K

5981C75G06

DBU17-30E

5981C76G08

DBU38-80SE

5981C77G08

7BCLS-5R

5982C36G04

DBU38-15K

5981C75G06

DBU27-30E

5981C76G08

DBU17-100SE

5981C77G09

7BCLS-6R

5982C36G05

DBU17-20K

5981C75G07

DBU38-30E

5981C76G08

DBU27-100SE

5981C77G09

7BCLS-9R

5982C36G06

DBU27-20K

5981C75G07

DBU17-40E

5981C76G09

DBU38-100SE

5981C77G09

7BCLS-12R

5982C36G07

DBU38-20K

5981C75G07

DBU27-40E

5981C76G09

DBU17-125SE

5981C77G10

7BCLS-18R

5982C36G08

DBU17-25K

5981C75G08

DBU38-40E

5981C76G09

DBU27-125SE

5981C77G10

7BCLS-24R

5982C36G09

DBU27-25K

5981C75G08

DBU17-50E

5981C76G10

DBU38-125SE

5981C77G10

8RBA4-.5

5982C44A01

DBU38-25K

5981C75G08

DBU27-50E

5981C76G10

DBU17-150SE

5981C77G11

8RBA4-3

5982C44A02

DBU17-30K

5981C75G09

DBU38-50E

5981C76G10

DBU27-150SE

5981C77G11

8RBA4-5E

5982C44A03

DBU27-30K

5981C75G09

DBU17-65E

5981C76G11

DBU38-150SE

5981C77G11

8RBA4-7E

5982C44A04

DBU38-30K

5981C75G09

DBU27-65E

5981C76G11

DBU17-175SE

5981C77G12

8RBA4-10E

5982C44A05

Volume 14—Fuses

www.comoso.com

CA08100016E—August 2011 www.eaton.com

V14-A3-15

Appendix 3—Catalog Number/Style Number Cross Reference

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

8RBA4-15E

5982C44A06

25RBA4-175E

5982C44A67

8RBT4-250E

5982C49A19

6MDSL-MB1600

5982C91G02

8RBA4-20E

5982C44A07

25RBA4-200E

5982C44A68

8RBT4-300E

5982C49A20

6MDSL-MB2000

5982C91G03

8RBA4-25E

5982C44A08

25RBA4-250E

5982C44A69

8RBT4-400E

5982C49A22

6MDSL-MC800

5982C92G01

8RBA4-30E

5982C44A09

25RBA4-300E

5982C44A70

15RBT4-20E

5982C49A32

6MDSL-MC1000

5982C92G02

8RBA4-40E

5982C44A10

38RBA4-.5

5982C44A76

15RBT4-25E

5982C49A33

6MDSL-MC1200

5982C92G03

8RBA4-50E

5982C44A11

38RBA4-3

5982C44A77

15RBT4-30E

5982C49A34

6MDSL-MC1600

5982C92G04

8RBA4-65E

5982C44A12

38RBA4-5E

5982C44A78

15RBT4-40E

5982C49A35

6MDSL-MC2000

5982C92G05

8RBA4-80E

5982C44A13

38RBA4-7E

5982C44A79

15RBT4-50E

5982C49A36

6MDSL-MD2500

5982C93G01

8RBA4-100E

5982C44A14

38RBA4-10E

5982C44A80

15RBT4-65E

5982C49A37

6MDSL-MD3000

5982C93G02

8RBA4-125E

5982C44A15

38RBA4-15E

5982C44A81

15RBT4-80E

5982C49A38

5BHLE-10E

5983C02G01

8RBA4-150E

5982C44A16

38RBA4-20E

5982C44A82

15RBT4-100E

5982C49A39

5BHLE-15E

5983C02G02

8RBA4-175E

5982C44A17

38RBA4-25E

5982C44A83

15RBT4-125E

5982C49A40

5BHLE-20E

5983C02G03

8RBA4-200E

5982C44A18

38RBA4-30E

5982C44A84

15RBT4-150E

5982C49A41

5BHLE-25E

5983C02G04

8RBA4-250E

5982C44A19

38RBA4-40E

5982C44A85

15RBT4-200E

5982C49A43

5BHLE-30E

5983C02G05

8RBA4-300E

5982C44A20

38RBA4-50E

5982C44A86

15RBT4-250E

5982C49A44

5BHLE-40E

5983C02G06

8RBA4-400E

5982C44A22

38RBA4-65E

5982C44A87

15RBT4-300E

5982C49A45

5BHLE-50E

5983C02G07

15RBA4-.5

5982C44A26

38RBA4-80E

5982C44A88

15RBT4-400E

5982C49A47

5BHLE-65E

5983C02G08

15RBA4-3

5982C44A27

38RBA4-100E

5982C44A89

25RBT4-20E

5982C49A57

5BHLE-80E

5983C02G09

15RBA4-5E

5982C44A28

38RBA4-125E

5982C44A90

25RBT4-25E

5982C49A58

5BHLE-100E

5983C02G10

15RBA4-7E

5982C44A29

38RBA4-150E

5982C44A91

25RBT4-30E

5982C49A59

5BHLE-125E

5983C02G11

15RBA4-10E

5982C44A30

38RBA4-175E

5982C44A92

25RBT4-40E

5982C49A60

5BHLE-150E

5983C02G12

15RBA4-15E

5982C44A31

38RBA4-200E

5982C44A93

25RBT4-50E

5982C49A61

5BHLE-175E

5983C02G13

15RBA4-20E

5982C44A32

38RBA4-250E

5982C44A94

25RBT4-65E

5982C49A62

5BHLE-200E

5983C02G14

15RBA4-25E

5982C44A33

38RBA4-300E

5982C44A95

25RBT4-80E

5982C49A63

5BHLE-250E

5983C02G15

15RBA4-30E

5982C44A34

DBU27-GDM-L

5982C45G05

25RBT4-100E

5982C49A64

5BHLE-300E

5983C02G16

15RBA4-40E

5982C44A35

DBU27-GDM-R

5982C45G06

25RBT4-125E

5982C49A65

5BHLE-350E

5983C02G17

15RBA4-50E

5982C44A36

DBU17-GDM-R

5982C45G07

25RBT4-150E

5982C49A66

5BHLE-400E

5983C02G18

15RBA4-65E

5982C44A37

DBU17-GDM-L

5982C45G08

25RBT4-200E

5982C49A68

5BHLE-450E

5983C02G19

15RBA4-80E

5982C44A38

2BCLS-25

5982C47G01

25RBT4-250E

5982C49A69

8BHLE-10E

5983C03G01

15RBA4-100E

5982C44A39

2BCLS-2R

5982C47G02

25RBT4-300E

5982C49A70

8BHLE-15E

5983C03G02

15RBA4-125E

5982C44A40

2BCLS-3R

5982C47G03

38RBT4-20E

5982C49A82

8BHLE-20E

5983C03G03

15RBA4-150E

5982C44A41

2BCLS-4R

5982C47G04

38RBT4-25E

5982C49A83

8BHLE-25E

5983C03G04

15RBA4-175E

5982C44A42

2BCLS-5R

5982C47G05

38RBT4-30E

5982C49A84

8BHLE-30E

5983C03G05

15RBA4-200E

5982C44A43

2BCLS-6R

5982C47G06

38RBT4-40E

5982C49A85

8BHLE-40E

5983C03G06

15RBA4-250E

5982C44A44

2BCLS-9R

5982C47G07

38RBT4-50E

5982C49A86

8BHLE-50E

5983C03G07

15RBA4-300E

5982C44A45

2BCLS-12R

5982C47G08

38RBT4-65E

5982C49A87

8BHLE-65E

5983C03G08

15RBA4-400E

5982C44A47

2BCLS-18R

5982C47G09

38RBT4-80E

5982C49A88

8BHLE-80E

5983C03G09

25RBA4-.5

5982C44A51

2BCLS-24R

5982C47G10

38RBT4-100E

5982C49A89

8BHLE-100E

5983C03G10

25RBA4-3

5982C44A52

DBU17-DL-L

5982C48G02

38RBT4-125E

5982C49A90

8BHLE-125E

5983C03G11

25RBA4-5E

5982C44A53

DBU17-DL-R

5982C48G03

38RBT4-150E

5982C49A91

8BHLE-150E

5983C03G12

25RBA4-7E

5982C44A54

DBU27-DL-L

5982C48G05

38RBT4-200E

5982C49A93

8BHLE-175E

5983C03G13

25RBA4-10E

5982C44A55

DBU27-DL-R

5982C48G06

38RBT4-250E

5982C49A94

8BHLE-200E

5983C03G14

25RBA4-15E

5982C44A56

8RBT4-20E

5982C49A07

38RBT4-300E

5982C49A95

8BHLE-250E

5983C03G15

25RBA4-20E

5982C44A57

8RBT4-25E

5982C49A08

4NPL-3500

5982C64G01

8BHLE-300E

5983C03G16

25RBA4-25E

5982C44A58

8RBT4-30E

5982C49A09

4NPL-5000

5982C64G02

8BHLE-350E

5983C03G17

25RBA4-30E

5982C44A59

8RBT4-40E

5982C49A10

6MDSL-MA150

5982C90G01

8HCL-200E

5983C05G01

25RBA4-40E

5982C44A60

8RBT4-50E

5982C49A11

6MDSL-MA200

5982C90G02

8HCL-250E

5983C05G02

25RBA4-50E

5982C44A61

8RBT4-65E

5982C49A12

6MDSL-MA250

5982C90G03

8HCL-300E

5983C05G03

25RBA4-65E

5982C44A62

8RBT4-80E

5982C49A13

6MDSL-MA300

5982C90G04

8HCL-350E

5983C05G04

25RBA4-80E

5982C44A63

8RBT4-100E

5982C49A14

6MDSL-MA400

5982C90G05

8HCL-175E

5983C05G05

25RBA4-100E

5982C44A64

8RBT4-125E

5982C49A15

6MDSL-MA600

5982C90G07

8HCL-150E

5983C05G06

25RBA4-125E

5982C44A65

8RBT4-150E

5982C49A16

6MDSL-MA800

5982C90G08

8HCL-125E

5983C05G07

25RBA4-150E

5982C44A66

8RBT4-200E

5982C49A18

6MDSL-MB1200

5982C91G01

8HCL-100E

5983C05G08

V14-A3-16

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

Appendix 3—Catalog Number/Style Number Cross Reference

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

8HCL-80E

5983C05G09

15LHLE-65E

5984C65G01

8CLT-18C

678C276G03

15RBA4-DL

9078A20A01

8HCL-65E

5983C05G10

15LHLE-80E

5984C65G02

2CLT-25C

678C276G04

15RBA4-DL

9078A20A01

15BHLE-10E

5984C05G01

15LHLE-100E

5984C65G03

5CLT-25C

678C276G05

15RBA4-DL

9078A20A01

15BHLE-15E

5984C05G02

15LHLE2-125E

5984C65G04

8CLT-25C

678C276G06

15RBA4-DL

9078A20A01

15BHLE-20E

5984C05G03

15LHLE2-150E

5984C65G05

2CLT-30C

678C277G04

15RBA4-DL

9078A20A01

15BHLE-25E

5984C05G04

15LHLE-175E

5984C65G06

2CLT-75C

678C282G01

15RBA4-DL

9078A20A01

15BHLE-30E

5984C05G05

15LHLE-200E

5984C65G07

8RBA4-ISHNT

678C283G05

15RBA4-DL

9078A20A01

15BHLE-40E

5984C05G06

15LHLE-125E

5984C65G08

8RBA4-ISHNT

678C283G05

38RBA4-DL

9078A20A02

15BHLE-50E

5984C05G07

15LHLE-150E

5984C65G09

15RBA4-ISHNT

678C283G06

5RBA2-PDM

9078A25G01

15BHLE-65E

5984C05G08

15LHLE-250E

5984C65G10

15RBA4-ISHNT

678C283G06

5RBA2-PDM

9078A25G01

15BHLE-80E

5984C05G09

15LHLE-300E

5984C65G11

25RBA4-ISHNT

678C283G07

5RBA2-GDM

9078A25G02

15BHLE-100E

5984C05G10

5LCLS-2R

676C546G15

25RBA4-ISHNT

678C283G07

5RBA2-GDM

9078A25G02

15BHLE-125E

5984C05G11

5LCLS-3R

676C546G16

38RBA4-ISHNT

678C283G08

14RBA2-PDM

9078A25G03

15BHLE-150E

5984C05G12

5LCLS-4R

676C546G17

38RBA4-ISHNT

678C283G08

14RBA2-PDM

9078A25G03

15BHLE-175E

5984C05G13

5LCLS-5R

676C546G18

8RDB4-SHNT

678C284G01

14RBA2-GDM

9078A25G04

15BHLE-200E

5984C05G14

5LCLS-6R

676C546G19

8RDB4-SHNT

678C284G01

14RBA2-GDM

9078A25G04

15BHLE-250E

5984C05G15

5LCLS-9R

676C546G22

15RDB4-SHNT

678C284G02

15RBA2-PDM

9078A25G05

15BHLE2-40E

5984C05G16

5LCLS-12R

676C546G25

15RDB4-SHNT

678C284G02

15RBA2-PDM

9078A25G05

15BHLE2-50E

5984C05G17

676C878G01

25RDB4-SHNT

678C284G03

25RBA2-PDM

9078A25G06

15BHLE2-65E

5984C05G18

Spring and shunt
assy. for 8BA4-NH

25RDB4-SHNT

678C284G03

25RBA2-PDM

9078A25G06

15BHLE2-80E

5984C05G19

38RDB4-SHNT

678C284G04

38RBA2-PDM

9078A25G07

15BHLE2-100E

5984C05G20

38RDB4-SHNT

678C284G04

38RBA2-PDM

9078A25G07

15BHLE2-125E

5984C05G21

8CLT-30CL

678C290G01

8RBA2-PDM

9078A25G08

8RBA4-INH-B

5984C17G01

15CLT-12C

678C295G02

8RBA2-PDM

9078A25G08

8RBA4-INH-B

5984C17G01

15CLT-8C

678C295G03

8RBA4-PDM

9078A25G08

8RBA2-INH-B

5984C18G01

15CLT-5C

678C295G04

8RBA4-PDM

9078A25G08

8RBA2-INH-B

5984C18G01

15CLT-4C

678C295G05

8RBA2-GDM

9078A25G09

DBU17-GNMP-L

5984C25G01

15CLT-18C

678C295G07

8RBA2-GDM

9078A25G09

DBU27-GNMP-L

5984C25G02

8CLT-30CS

680C386G01

8RBA4-GDM

9078A25G09

DBU38-GNMP-L

5984C25G03

5CLT-30C

680C386G02

8RBA4-GDM

9078A25G09

DBU17-GNMP-R

5984C25G04

5CLT-60C

680C386G03

15RBA2-DL

9078A26A01

DBU27-GNMP-R

5984C25G05

5CLT-45C

680C386G05

15RBA2-DL

9078A26A01

DBU38-GNMP-R

5984C25G06

8CLT-45C

680C386G06

15RBA2-DL

9078A26A01

DBU17-GNM-L

5984C25G07

2CLT-150C

680C387G01

15RBA2-DL

9078A26A01

DBU27-GNM-L

5984C25G08

2CLT-90C

680C387G02

15RBA2-DL

9078A26A01

DBU38-GNM-L

5984C25G09

DBU-EFOD

7187A11G02

15RBA2-DL

9078A26A01

DBU17-GNM-R

5984C25G10

DBU-EFID

7187A11G04

15RBA2-DL

9078A26A01

DBU27-GNM-R

5984C25G11

CXN-CLAMP

7275A85G02

15RBA2-DL

9078A26A01

DBU38-GNM-R

5984C25G12

5RBA4-PDM

9078A19G01

38RBA2-DL

9078A26A02

DBU17-NL-L

5984C29G01

5RBA4-PDM

9078A19G01

38RBA2-DL

9078A26A02

DBU27-NL-L

5984C29G02

5RBA4-GDM

9078A19G02

38RBA2-DL

9078A26A02

DBU38-NL-L

5984C29G03

5RBA4-GDM

9078A19G02

38RBA2-DL

9078A26A02

DBU17-NL-R

5984C29G04

14RBA4-PDM

9078A19G03

15RBA2-NL

9078A30A01

DBU27-NL-R

5984C29G05

14RBA4-PDM

9078A19G03

15RBA2-NL

9078A30A01

DBU38-NL-R

5984C29G06

14RBA4-GDM

9078A19G04

15RBA2-NL

9078A30A01

DBU17-NLP-L

5984C29G07

14RBA4-GDM

9078A19G04

15RBA2-NL

9078A30A01

DBU27-NLP-L

5984C29G08

15RBA4-PDM

9078A19G05

15RBA2-NL

9078A30A01

DBU38-NLP-L

5984C29G09

15RBA4-PDM

9078A19G05

15RBA2-NL

9078A30A01

DBU17-NLP-R

5984C29G10

25RBA4-PDM

9078A19G06

15RBA2-NL

9078A30A01

DBU27-NLP-R

5984C29G11

25RBA4-PDM

9078A19G06

15RBA2-NL

9078A30A01

DBU38-NLP-R

5984C29G12

38RBA4-PDM

9078A19G07

38RBA2-NL

9078A30A02

DBU27-DM

5984C38G01

38RBA4-PDM

9078A19G07

38RBA2-NL

9078A30A02

DBU17-DM

5984C39G01

15RBA4-DL

9078A20A01

38RBA2-NL

9078A30A02

Spring and shunt
676C878G02
assy. for 15BA4-NH
25RBA2-NH
8RBA2-NH
8RBA2-NH
15RBA2-NH
15RBA2-NH
38RBA2-NH
8RBA4-NH
8RBA4-NH
15RBA4-NH
15RBA4-NH
25RBA4-NH
38RBA4-NH
2CLE-15E
2CLE-20E
2CLE-25E
5CLE-15E
5CLE-20E
5CLE-25E
8CLE-15E
8CLE-20E
8CLE-25E
15CLE-15E
15CLE-20E
15CLE-25E
2CLT-5C
8CLT-5C
5CLT-8C
8CLT-8C
2CLT-12C
5CLT-12C
2CLT-18C
5CLT-18C

676C880G03
677C370G01
677C370G01
677C370G02
677C370G02
677C370G04
677C371G01
677C371G01
677C371G02
677C371G02
677C371G03
677C371G04
678C240G01
678C240G02
678C240G03
678C240G04
678C240G05
678C240G06
678C240G07
678C240G08
678C240G09
678C240G10
678C240G11
678C240G12
678C248G01
678C248G03
678C248G05
678C248G06
678C249G01
678C249G02
678C276G01
678C276G02

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com

V14-A3-17

Appendix 3—Catalog Number/Style Number Cross Reference

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

Style Number

Catalog Number

38RBA2-NL

9078A30A02

5RBA2-GNM

9078A33G16

5CLE-GDM-C

9078A65G31

15CXN-GNM-G

9570D05G02

15RBA4-NL

9078A30A03

8RBA2-GNM

9078A33G17

8CLE-GDM-C

9078A65G32

15CXN-NL-G

9570D05G06

15RBA4-NL

9078A30A03

8RBA2-GNM

9078A33G17

15CLE-GDM-C

9078A65G33

15CXN-GDM-G

9570D06G01

15RBA4-NL

9078A30A03

8RBA4-GNM

9078A33G17

2CLE-GDM-D

9078A65G34

15CXN-DL-G

9570D06G03

15RBA4-NL

9078A30A03

8RBA4-GNM

9078A33G17

5CLE-GDM-D

9078A65G35

15CXN-DF-G

9570D06G05

15RBA4-NL

9078A30A03

14RBA2-GNM

9078A33G18

8CLE-GDM-D

9078A65G36

15CLT-30C

9570D10G01

15RBA4-NL

9078A30A03

14RBA2-GNM

9078A33G18

15CLE-GDM-D

9078A65G37

15CXN-GNM-F

9570D33G01

15RBA4-NL

9078A30A03

5RBA4-GNM

9078A33G19

2CLE-GDM-E

9078A65G38

15CXN-NL-F

9570D33G02

15RBA4-NL

9078A30A03

5RBA4-GNM

9078A33G19

5CLE-GDM-E

9078A65G39

15CXN-GNM-D

9570D33G03

38RBA4-NL

9078A30A04

14RBA4-GNM

9078A33G21

8CLE-GDM-E

9078A65G40

15CXN-NL-D

9570D33G04

38RBA4-NL

9078A30A04

14RBA4-GNM

9078A33G21

CLE-NL-C

9078A67G02

15CXN-GDM-F

9570D34G01

15RBA8-NL

9078A30A05

5RBA8-GNM

9078A33G22

CLE-DL-D

9078A67G03

15CXN-DL-F

9570D34G02

15RBA8-NL

9078A30A05

5RBA8-GNM

9078A33G22

CLE-NL-D

9078A67G03

5BCLS-32R

9570D64G01

15RBA8-NL

9078A30A05

5RBA8-GNM

9078A33G22

CLE-NL-E

9078A67G04

5BCLS-36R

9570D64G02

15RBA8-NL

9078A30A05

5RBA8-PNM

9078A33G22

CLE-NLC-E

9078A67G15

5BCLS-44R

9570D64G03

15RBA8-NL

9078A30A05

5RBA8-PNM

9078A33G22

CLE-NLC-C

9078A67G17

5BCLS-600E

9570D64G04

15RBA8-NL

9078A30A05

5RBA8-PNM

9078A33G22

CLE-NLC-D

9078A67G20

5BCLS-750E

9570D64G05

15RBA8-NL

9078A30A05

8RBA8-GNM

9078A33G23

2CLE-PNM-C

9078A68G10

7BCLS-44R

9570D69G01

15RBA8-NL

9078A30A05

8RBA8-GNM

9078A33G23

5CLE-PNM-C

9078A68G11

7BCLS-44R

9570D69G01

15RBA8-NL

9078A30A05

8RBA8-GNM

9078A33G23

8CLE-PNM-C

9078A68G12

5CLE-1100E

9570D70G01

38RBA8-NL

9078A30A06

14RBA8-GNM

9078A33G24

15CLE-PNM-C

9078A68G13

5CLE-1350E

9570D70G02

38RBA8-NL

9078A30A06

14RBA8-GNM

9078A33G24

15CLE-HPNM-C

9078A68G14

38RBA8-NL

9078A30A06

14RBA8-GNM

9078A33G24

2CLE-PNM-D

9078A68G15

8RBA2-PNM

9078A33G02

15RBA2-PNM

9078A33G25

5CLE-PNM-D

9078A68G16

8RBA2-PNM

9078A33G02

15RBA2-PNM

9078A33G25

8CLE-PNM-D

9078A68G17

8RBA4-PNM

9078A33G02

15RBA4-PNM

9078A33G26

15CLE-PNM-D

9078A68G18

8RBA4-PNM

9078A33G02

15RBA4-PNM

9078A33G26

15CLE-HPNM-D

9078A68G19

14RBA2-PNM

9078A33G03

15RBA8-PNM

9078A33G27

2CLE-PNM-E

9078A68G20

14RBA2-PNM

9078A33G03

15RBA8-PNM

9078A33G27

5CLE-PNM-E

9078A68G21

25RBA2-PNM

9078A33G04

15RBA8-PNM

9078A33G27

8CLE-PNM-E

9078A68G22

25RBA2-PNM

9078A33G04

25RBA8-PNM

9078A33G27

15CLE-PNM-E

9078A68G23

38RBA2-PNM

9078A33G05

25RBA8-PNM

9078A33G27

2CLE-GNM-C

9078A68G31

38RBA2-PNM

9078A33G05

25RBA8-PNM

9078A33G27

5CLE-GNM-C

9078A68G32

5RBA2-PNM

9078A33G06

CLE-DF-C

9078A63G02

8CLE-GNM-C

9078A68G33

5RBA2-PNM

9078A33G06

CLE-DF-D

9078A63G03

15CLE-GNM-C

9078A68G34

5RBA4-PNM

9078A33G06

CLE-DF-E

9078A63G04

2CLE-GNM-D

9078A68G35

5RBA4-PNM

9078A33G06

CLE-DL-C

9078A63G04

5CLE-GNM-D

9078A68G36

14RBA4-PNM

9078A33G08

CLE-DL-E

9078A64G04

8CLE-GNM-D

9078A68G37

14RBA4-PNM

9078A33G08

2CLE-PDM-C

9078A65G10

15CLE-GNM-D

9078A68G38

25RBA4-PNM

9078A33G09

5CLE-PDM-C

9078A65G11

2CLE-GNM-E

9078A68G39

25RBA4-PNM

9078A33G09

8CLE-PDM-C

9078A65G12

5CLE-GNM-E

9078A68G40

38RBA4-PNM

9078A33G10

15CLE-PDM-C

9078A65G13

8CLE-GNM-E

9078A68G41

38RBA4-PNM

9078A33G10

15CLE-HPDM-C

9078A65G14

8CXN-60C

9570D01G01

8RBA8-PNM

9078A33G12

2CLE-PDM-D

9078A65G15

8CXN-100C

9570D01G02

8RBA8-PNM

9078A33G12

5CLE-PDM-D

9078A65G16

8CXN-125C

9570D01G03

8RBA8-PNM

9078A33G12

8CLE-PDM-D

9078A65G17

8CXN-150C

9570D01G04

14RBA8-PNM

9078A33G13

15CLE-PDM-D

9078A65G18

8CXN-200C

9570D01G05

14RBA8-PNM

9078A33G13

15CLE-HPDM-D

9078A65G19

8CXN-250C

9570D01G06

14RBA8-PNM

9078A33G13

2CLE-PDM-E

9078A65G20

15CXN-45C

9570D02G02

38RBA8-PNM

9078A33G15

5CLE-PDM-E

9078A65G21

15CXN-60C

9570D02G03

38RBA8-PNM

9078A33G15

8CLE-PDM-E

9078A65G22

15CXN-75C

9570D02G04

38RBA8-PNM

9078A33G15

15CLE-PDM-E

9078A65G23

15CXN-85C

9570D02G05

5RBA2-GNM

9078A33G16

2CLE-GDM-C

9078A65G30

15CXN-100C

9570D02G06

V14-A3-18

Volume 14—Fuses CA08100016E—August 2011 www.eaton.com

www.comoso.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Appligent                       : StampPDF Batch 5.1 Jan 18 2010, 9.0.1
Author                          : Zoltun Design
Create Date                     : 2011:08:24 13:35:16-04:00
Modify Date                     : 2014:03:01 19:43:23-08:00
Subject                         : Fuses
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.352151, 2008/07/27-22:00:37
Metadata Date                   : 2014:03:01 19:43:23-08:00
Creator Tool                    : Adobe InDesign CS4 (6.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 13001 bytes, use -b option to extract)
Instance ID                     : uuid:10ef7a8f-52e2-4a43-afd8-f19dd1d70e75
Document ID                     : xmp.did:856700E764CEE011811AF9FDE3A93365
Original Document ID            : xmp.did:ED1567C354C3E011B3FFAC5DA4A7BE81
Rendition Class                 : proof:pdf
History Action                  : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:ED1567C354C3E011B3FFAC5DA4A7BE81, xmp.iid:EE1567C354C3E011B3FFAC5DA4A7BE81, xmp.iid:EF1567C354C3E011B3FFAC5DA4A7BE81, xmp.iid:F01567C354C3E011B3FFAC5DA4A7BE81, xmp.iid:F11567C354C3E011B3FFAC5DA4A7BE81, xmp.iid:816700E764CEE011811AF9FDE3A93365, xmp.iid:826700E764CEE011811AF9FDE3A93365, xmp.iid:836700E764CEE011811AF9FDE3A93365, xmp.iid:846700E764CEE011811AF9FDE3A93365, xmp.iid:856700E764CEE011811AF9FDE3A93365, xmp.iid:866700E764CEE011811AF9FDE3A93365, xmp.iid:A33D717176CEE011820CFD0A37EB7532, xmp.iid:A43D717176CEE011820CFD0A37EB7532
History When                    : 2011:08:10 09:29:24-04:00, 2011:08:10 09:34:09-04:00, 2011:08:10 09:34:09-04:00, 2011:08:10 09:37:58-04:00, 2011:08:10 09:41:18-04:00, 2011:08:24 11:22:38-04:00, 2011:08:24 11:22:38-04:00, 2011:08:24 11:23:26-04:00, 2011:08:24 11:30:37-04:00, 2011:08:24 11:30:37-04:00, 2011:08:24 11:34:11-04:00, 2011:08:24 13:34:46-04:00, 2011:08:24 13:34:50-04:00
History Software Agent          : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0
History Changed                 : /, /metadata, /, /, /metadata, /;/metadata, /, /metadata, /;/metadata, /, /, /
Derived From Instance ID        : xmp.iid:846700E764CEE011811AF9FDE3A93365
Derived From Document ID        : xmp.did:826700E764CEE011811AF9FDE3A93365
Derived From Original Document ID: xmp.did:ED1567C354C3E011B3FFAC5DA4A7BE81
Derived From Rendition Class    : default
Manifest Link Form              : DirectStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches
Manifest Reference Instance ID  : uuid:EEC144858F91DD11AC73A4AED5B610AD, uuid:e13e761e-9e62-d042-ad66-e0f1cfe2be47
Manifest Reference Document ID  : uuid:C7143732532111DD958FC1F669DED174, xmp.did:54610AFB38206811822AC6BD61F944EB
Doc Change Count                : 62
Format                          : application/pdf
Title                           : Volume 14 iBook
Creator                         : Zoltun Design
Description                     : Fuses
Producer                        : Appligent StampPDF Batch, version 5.1
Trapped                         : False
Page Count                      : 291
EXIF Metadata provided by EXIF.tools