AWH SERIES FAN-FORCED WALL HEATERS 470 Beauty Spot Rd. E, Bennettsville, SC 29512 CAPACITIES 1500, 2000, 3000, 4000 or 4800 Watts 120, 208, 240, 277, 347 or 600V 1Ø 3000, 4000 or 4800 Watts 208 or 240, 347, 600V, 3Ø FILE #E21609 Thermostat Range: 40 - 90 Degrees F Air Movement: 100 CFM JOB NAME: _________________________________________________________________ LOCATION: _________________________________________________________________ ARCHITECT: ________________________________________________________________ ENGINEER: _________________________________________________________________ CONTRACTOR: ______________________________________________________________ SUBMITTED BY: _____________________________________________________________ DATE: ______________________________________________________________________ ITEM QTY. CATALOG NUMBER ACCESSORIES AND CONTROLS SUBMITTED BY: ZSS-QAWH4 TAG ITEM LENGTH QTY. DATE WATTS CAT. NO. APPROVED BY: (03-06) VOLTS TAG PHASE Ø AMPS BUILT-IN CONTROLS DESCRIPTION DATE Printed in U.S.A. AWH SERIES - COMMERCIAL/ARCHITECTURAL FAN FORCED WALL HEATERS SUBMITTAL SHEET AWH SERIES ARCHITECT’S AND ENGINEER’S SPECIFICATIONS* The heating equipment shall include an electric automatic fan forced air heater suitable for large area heating, as manufactured by QMark, A Marley Engineered Products Brand, Bennettsville, SC. The heater shall be designed for wall mounting, recess or surface. Heaters shall be UL listed. 470 Beauty Spot Rd. E, Bennettsville SC 29512 SELECTION CHART CATALOG NO. VOLTS PH. AMPS WATTS BTU/HR WIRE SIZE AWH3150 AWH3180 AWH4408* 120 120 208 1 1 1 240 1 208 1 277 1 240 1 AWH4307* 277 1 AWH4303 AWH4508 AWH4504 347 208 240 208 277 240 347 600 208 208 240 240 600 1 1 1 1 1 1 1 3 3 3 3 3 3 1500 1800 4000 2000 4000 2000 3000 1500 4000 2000 3000 1500 3000 1500 3000 4800 4800 3600 4800 3600 4800 4800 4000 4800 4000 4800 3000 5120 6142 13650 6825 13650 6825 10235 5120 13650 6825 10235 5120 10235 5120 10235 16380 16380 12285 16380 12285 16380 16380 13650 16380 13650 16380 10235 12 AWG 12 AWG 10 AWG AWH4404* 12.5 15 19.2 9.6 16.7 8.3 14.4 7.2 14.4 7.22 12.5 6.3 10.8 5.4 8.6 23.1 20 17.3 17.3 15 13.8 4.6 11.1 13.3 9.6 11.6 3.0 AWH4407* AWH4507 AWH4503 AWH4506 AWH44083 AWH45083 AWH44043 AWH45043 AWH4306 10 AWG & 12 AWG FAN AND FAN MOTOR: The fan shall be five-bladed aluminum. The fan motor shall be totally enclosed. 12 AWG 14 AWG 10 AWG 10 AWG 10 AWG 12 AWG 14 AWG 14 AWG 12 AWG 14 AWG 14 AWG 14 AWG AWH-R2 (24 volt) AWH-R12 (120 volt) AWH-S-1 AWH-S-2 AWH-SM LFK-SFC FAN DELAY SWITCH: Fan control shall be of bimetallic, snap-action type and shall activate fan after heating element reaches operating temperature. The fan shall continue to operate after the thermostat is satisfied and until the heating element is cool. THERMOSTAT: The tamper-proof thermostat shall be of the bi-metallic, snap-action type with enclosed contacts. It shall be completely concealed behind the front cover to become tamper proof. THERMAL CUTOUT: A thermal cutout shall be built into the system to shut off the heater in the event of overheating. DISCONNECT SWITCH: A double-pole single throw disconnect switch shall be mounted on the back box for positive disconnect of power supply. It will be completely concealed behind the front grid panel. ACCESSORIES AWH-PE HEATING ELEMENT: The heating element shall be of the non-glowing design consisting of an 80/20 nickelchromium resistance wire enclosed in a steel sheath to which plate fins are copper brazed. It shall be warranted for 5 years. 12 AWG *Heaters shipped at higher wattage. Units can be converted to half-wattage in field. CATALOG NO. HEATER ASSEMBLY: The heater assembly which fits into the back box shall consist of a fan panel upon which is mounted all of the operational parts of the heater. DESCRIPTION Pneumatic/Electric switch. Factory set at 10 psig to “make” on pressure drop. May be field wired to “break’ on pressure drop. Pressure set point adjustable to 30 psig. (Field installed.) Time delay relay 40-60 seconds to close when energized. Use 120V or 24V power supply from remote source. (Field installed.) 1” deep surface mounting frame for semirecessed installation. Same as above except 2” deep. Surface mounting frame for surface installations. Painted to match heater decor, 313/16” deep. 14 Gauge security front cover. PNEUMATIC/ELECTRIC SWITCH: An optional pneumatic/electric switch shall be available for use with energy management systems employing pneumatic pressure devices for controlling comfort levels and setback operations. LOW VOLTAGE RELAYS: Normally open 24-volt and 120-volt low voltage holding coil relays shall be available as optional equipment to control 208, 240, or 277 volt heaters in conjunction with central energy control systems. The built-in thermostat can then be used as one of the thermostats in an automatic night set back operation. DIMENSIONS A SM BACK BOX: The back box shall be designed for duty as a recessed rough-in box in either masonry or frame installations and is also used with the surface mounting frame in surface mounting installations. The back box shall be 20-gauge galvanized steel and shall contain knockouts through which power leads are brought. S1 S2 MODEL SM S2 S1 RECESSED "A" "B" "C" "D" RECESSED THICKNESS FRONT TOTAL DIM. OF FRAME COVER EXT. INTO DIM. ROOM – 3-13/16'' 1-1/2'' 5-5/16'' 1-13/16'' 2'' 1-1/2'' 3-1/2'' 2-13/16'' 1'' 1-1/2'' 2-1/2'' 3-3/4'' – 1-1/2'' 1-12'' FRONT PANEL: The front panel shall be of the bar grille type and shall be constructed of 16-gauge cold-rolled steel, welded into a uniform grille and finished in baked enamel to direct the warmed air toward the floor. The front grille shall be surrounded by a decorative satinfinish aluminum "picture" frame. THREE PIECE DESIGN: The heater shall be made of a back box, a heater assembly, and a front panel. *QMark reserves the right to change specifications without prior notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Signing Date : 2010:03:16 09:58:22-04:00 Signing Authority : ARE Acrobat Product v8.0 P23 0002337 Document Usage Rights : FullSave Annotation Usage Rights : Create, Delete, Modify, Copy, Import, Export Form Usage Rights : Add, FillIn, Delete, SubmitStandalone Signature Usage Rights : Modify XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:30 Producer : Acrobat Distiller 6.0.1 for Macintosh Creator Tool : QuarkXPress: pictwpstops filter 1.0 Create Date : 2006:03:16 14:09:21-05:00 Modify Date : 2010:03:16 09:58:22-04:00 Metadata Date : 2010:03:16 09:58:22-04:00 Document ID : uuid:60de9097-b520-11da-8a77-000a95ba851c Instance ID : uuid:c5dc5b8d-f985-2e49-9f7c-b703069018a5 Format : application/pdf Title : ZSS-QAWH4 Creator : Chris English Has XFA : No Page Count : 2 Author : Chris EnglishEXIF Metadata provided by EXIF.tools