Product Detail Manual

39113-Catalog 39113-Catalog 39113-Catalog 078275 Batch5 unilog cesco-content

39113-Catalog 39113-Catalog 39113-Catalog 614573 Batch5 unilog cesco-content

109360-Catalog 109360-Catalog 109360-Catalog 078275 Batch7 unilog cesco-content

61972-Catalog 61972-Catalog 61972-Catalog 078275 Batch12 unilog cesco-content

2014-11-11

: Pdf 81609-Attachment 81609-Attachment Batch12 unilog

Open the PDF directly: View PDF PDF.
Page Count: 170

DownloadProduct Detail Manual
Open PDF In BrowserView PDF
Global Partners
Product Catalog

Product Catalog

Energy Management Control Solutions
Energy Control Panels
Ti m ers Weatherproof

Intermatic Incorporated, along with its European subsidiary Grässlin GmbH, are focusing
on the objectives and resources of businesses around the world to develop practical
energy-management solutions. This global partnership helps businesses become more
efficient and keeps our environment clean.
To help extend our reach to a global audience, we offer additional first-class service and solutions
for our worldwide distributors on the Grässlin website. Visit www.graesslin.de to learn more about
Grässlin solutions.

7777 Winn Road, Spring Grove, IL 60081

Phone: (815) 675-2321

©2013 Intermatic Inc.
300TS10098

Iss. 2013

www.intermatic.com

HVACR Time Switches
Hour Meters Surge Protection
Defrost Timers Sensors
Pool & Spa Controls

Founded: 1891
Headquarters: Spring Grove, Illinois
Facilities: E
 l Paso, Texas; Juarez, Mexico; Mississauga, Canada;
St. Georgen, Germany; Peterzell, Germany; Madrid, Spain
Total Employees: 800
Since 1891, Intermatic has been a family-owned business dedicated to delivering
quality service to its customers. This steadfast commitment has helped Intermatic
become a global leader in energy management solutions.
From its trademark yellow dial time switch to electronic energy controls, Intermatic is
a leading manufacturer of energy-management solutions for electrical, HVACR,
pool/spa, and OEM markets. Intermatic products cover a wide range of solutions,
including facility management, municipalities, manufacturing, agricultural, and
construction.
Intermatic bolsters its innovative solutions with a best-in-class Technical
Service team for distributors, contractors, specifiers, and OEMs.
This new product catalog reinforces our now 122-year commitment to excellence.

Table of
Contents
Electronic Time Switches
Pages 9-25

Electromechanical Time Switches
Pages 27-29

Mechanical Time Switches
Pages 31-46

Timers
Pages 47-59

Sensors
Pages 61-77

Hour Meters
Pages 79-85

Defrost/HVACR
Pages 87-92

Surge
Pages 93-103

Weatherproof Covers
Pages 105-111

Pool & Spa Controls
Pages 113-144

Enclosures & Accessories
Pages 145-154

Reference

Pages 155-169
www.intermatic.com

3

A Powerful New Way to See Intermatic

w w w. i n t e r m a t i c . c o m

Improved navigation
makes it easier to learn
about all our capabilities

Keeps you in tune with
our latest Innovations

Sleek new design makes
it quicker to find the right info

Quick links to our
dedicated customer
& product support

HVACR solutions center
provides a reservoir of
Info to find the solution
you need

Find Your Energy Management Solution

with our new dynamic solutions tab

Solution tab helps you
navigate deeper and faster
through our solutions

Intuitive industry tabs removes
guess work from your search

4

Vivid application imaging

In-depth application list
facilitates a quicker search
to find your solutions

Find the Resource you Need
with Our New Multimedia Library

Videos
How-to and promotional
videos featuring our newest
and most innovative products!

Instruction Manuals &
Product Brochures
Find everything you need to
make our products work for you!

Cross Reference

Downloadable Forms
Order trippers hassle free with
our downloadable form.

An easy, interactive addition
to our printed cross reference,
helping you make the switch
to Intermatic.

www.intermatic.com

5

Icon Legend:
Heating, Ventilation,
Air Conditioning &
Refrigeration
CSA Tested to Both
CSA & UL Standards

UL Component
Recognized US &
Canada

UL Component
Recognized

Underwriters
Laboratories Listed

Canadian Standards
Association Approved

CSA Tested to
UL Standards

TITLE

UL Tested to Both
UL & CSA Standards

European Conformity

20

COMPLIANT

California Title 20
Compliant

Product Index
Symbols

2T308A 	 ............................150
2T511GA 	 ................... 147, 148
2T2040GA ...........................148
2T2331GA ...........................148
2T2365GA ...........................150
2T2485GA ...........................148
2T2500GA ...........................149
2T2502GA ...........................149
2T2926A 	 ............................149
6LV1352 	 ..............................68
6LV1352R 	..............................68
21T156A 	 ................... 144, 154
21T166A 	 ............................144
22--00012 ...........................153
22T338GR .................. 150, 152
22T904A 	 ................... 144, 154
24EB5495 ............................154
24EB5524 ............................154
24EG5133 ...........................101
24T5265A ............................154
101--00040 .........................153
107SB189 ...........................153
107SB192 ...........................153
107SB216 ...........................153
107SB217 ...........................153
107SB234 ...........................153
107T73 	 ............................153
107T119 	 ............................153
107TN221 ...........................153
107TN222 ...........................153
119T86A 	 ............................153
119T267 	 ............................153
119T340 	 ............................153
124T1948 ............................152
124T1952 ............................152
124T2097 ............................153
124T2247 ............................153
124T2411A ..........................152
124T2530A ..........................153
124TP2608A ........................153
131T68GA ...........................153
133RC1144 .........................153
133T698A ............................153
133T700A ............................153
133T701A ............................153
133T773A ............................153
133T1115A ..........................153
143PS307 ...........................153
143RC126 ...........................153
143RC140 ...........................153
143RC151 ...........................152
143T135 	 ................... 152, 153
143T136 	 ................... 152, 153
143T145A ............................153
146MT573 ...........................154
146MT574 ...........................154
146MT575 ...........................154
146MT577 ...........................154
146MT579 ...........................154
148FD5024 .........................154
148FD5025 .........................154
148FD5029 .........................154
148FD5030 .........................154
148FD5031 .........................154
148FD5032 .........................154
148FD5033 .........................154
148FD5034 .........................154
148FD5035 .........................154
148FD5036 .........................154

6

148FD5037 .........................154
148FD5038 .........................154
148FD5039 .........................154
148FD5052 .........................154
148FD5054 .........................154
148FD5056 .........................154
148FD5059 .........................154
148FD5060 .........................154
148FD5061 .........................154
148FD5062 .........................154
148FD5063 .........................154
148FD5064 .........................154
148FD5066 .........................154
148FD5068 .........................154
148FD5070 .........................154
148FD5071 .........................154
148FD5072 .........................154
148FD5073 .........................154
148FD5075 .........................154
148FD5076 .........................154
148FD5077 .........................154
148FD5078 .........................154
148FD5079 .........................154
148FD5080 .........................154
156--01318A .......................153
156EB1945A .......................153
156PA13713A .....................154
156PA13714A .....................154
156PA13715A .....................154
156PA14336A .....................154
156PB10398A .....................152
156T1948A ..........................153
156T1949A ..........................153
156T1950A ..........................153
156T1954A ..........................153
156T1957A ..........................153
156T1978A ..........................152
156T2548A ..........................153
156T3085A ..........................153
156T3230A ..........................153
156T3492A ..........................153
156T4042A ................. 144, 154
156T6738A ..........................152
176ET9A 	 ............................154
176ET10A ............................154
178PA28A .................. 115, 154
178T24 	 ............................154

A

AG1BRKT 	................... 100, 154
AG240C3 	............................100
AG2083C3 .................... 95, 100
AG2401C3 .............................95
AG2403C3 .................... 95, 100
AG3000 	 ...............95, 97, 143
AG4801C3 .............................95
AG4803C3 .................... 95, 100
AG6503C3 .................... 95, 100
AG6503L3 .................... 95, 100
AG24013 	............................100
AG48013 	............................100
AG Series 	............................100

B

BEZ-55BLACKU ............. 83, 153
BEZ-55GRAYU ............... 83, 153
BEZ-72PU 	..................... 83, 153
BEZ-72U 	 ..................... 83, 153

C

C8800 Series .........................38
C8815 	 ..............................38
C8835 	 ..............................38
C8845 	 ..............................38
C8865 	 ..............................38
C8866 	 ..............................38
CA8750 	 ............................154
CT2000 	 ..............................25

D

DC-FME 	 ............................153
DC-FME-A ............................153
DT620 	 ..............................59
DTAV40 	 ..............................91
DTAV40E 	 ..............................89
DTAV40E2 	..............................89
DTAV40IM 	..............................91
DTAV40M 	..............................91
DTAV40Q 	 ..............................91
DTAV40Q-M ...........................91
DTAV40 Series ........................91
DT-B 	
..................... 91, 153

E

E150 	
............................151
E150 Type 1 Enclosure ..........151
E200 	
............................151
E200 Type 3R Rainproof
Enclosure ............151
E300 Compact Type 3R Rainproof
Enclosure ............151
E1010 	 ..............................57
E1020 	 ..............................57
EH10 	
..............................25
EH40 	
..............................25
EI200 	 ..............................53
EI200LA 	 ..............................53
EI200 Series ...........................53
EI200W 	 ..............................53
EI205 	 ..............................53
EI205LA 	 ..............................53
EI205W 	 ..............................53
EI210 	 ..............................53
EI210LA 	 ..............................53
EI210W 	 ..............................53
EI215 	 ..............................53
EI215LA 	 ..............................53
EI215W 	 ..............................53
EI220 	 ..............................53
EI220LA 	 ..............................53
EI220W 	 ..............................53
EI230 	 ..............................53
EI230LA 	 ..............................53
EI230W 	 ..............................53
EI235 	 ..............................53
EI235LA 	 ..............................53
EI235W 	 ..............................53
EI400C 	 ..............................52
EI400LAC 	..............................52
EI400 Series ...........................52
EI400WC 	 ..............................52
EI500C 	 ..............................49
EI500LAC 	..............................49
EI500 Series ...........................49
EI500WC 	 ..............................49
EI600C 	 ..............................48
EI600LAC 	..............................48
EI600 Series ...........................48

EI600WC 	 ..............................48
EJ351 	 ..............................51
EJ500 	 ..............................51
EJ600 	 ..............................51
EJ600A 	 ..............................51
EJ600 Series ..........................51
EK4536 	 ..............................73
ET801M 	 ..............................17
ET1105C 	 ..............................17
ET1105CPD82 .......................17
ET1105CR ..............................17
ET1105M 	..............................17
ET1115C 	 ..............................17
ET1115CPD82 .......................17
ET1115CR ..............................17
ET1115M 	..............................17
ET1125C 	 ..............................17
ET1125CPD82 .......................17
ET1125CR ..............................17
ET1125M 	..............................17
ET1705C 	 ..............................17
ET1705CPD82 .......................17
ET1705CR ..............................17
ET1705M 	..............................17
ET1715C 	 ..............................17
ET1715CPD82 .......................17
ET1715CR ..............................17
ET1715M 	..............................17
ET1725C 	 ..............................17
ET1725CPD82 .......................17
ET1725CR ..............................17
ET1725M 	..............................17
ET8015C 	 ..............................17
ET8015CPD82 .......................17
ET8015CR ..............................17
ET8115C 	 ..............................17
ET8115CPD82 .......................17
ET8115CR ..............................17
ET8115M 	..............................17
ET8215C 	 ..............................17
ET8215CPD82 .......................17
ET8215CR ..............................17
ET8215M 	..............................17
ET8415CR ..............................15
ET9100 	 ..................... 14, 153
ET9232 	 ..................... 14, 153
ET9250 	 ..................... 14, 153
ET90000 Series ......................13
ET90115C ..............................13
ET90115CE ............................13
ET90115CR ............................13
ET90115CRE ..........................13
ET90115M .............................13
ET90215C ..............................13
ET90215CE ............................13
ET90215CR ............................13
ET90215CRE ..........................13
ET90215M .............................13
ET90415CR ............................13
ET90815CR ............................13
ET91215CR ............................13
ET91615CR ............................13
ET Series 	 ..............................17
Extra-Duty Die-Cast Covers ...107

F

FD2H 	
FD2HW 	
FD4H 	
FD4HW 	

..............................54
..............................54
..............................54
..............................54

FD5M 	 ..............................54
FD5MW 	 ..............................54
FD6H 	
..............................54
FD6HH 	 ..............................54
FD6HHW 	 ..............................54
FD6HW 	 ..............................54
FD12HC 	 ..............................54
FD12HH 	 ..............................54
FD12HHP 	............................154
FD12HHW 	..............................54
FD12HWC	 .............................54
FD15MAC 	..............................54
FD15MC 	 ..............................54
FD15MH 	 ..............................54
FD15MHW .............................54
FD15MP 	 ............................154
FD15MPW ............................154
FD15MWC .............................54
FD30MAC 	..............................54
FD30MC 	 ..............................54
FD30MH 	 ..............................54
FD30MP 	 ............................154
FD30MPW ............................154
FD30MWC .............................54
FD30MWH .............................54
FD32H 	 ..............................54
FD32HW 	 ..............................54
FD34H 	 ..............................54
FD34HW 	 ..............................54
FD36H 	 ..............................54
FD46H 	 ..............................54
FD46HW 	 ..............................54
FD60MAC 	..............................54
FD60MC 	 ..............................54
FD60MH 	 ..............................54
FD60MHW .............................54
FD60MP 	 ............................154
FD60MPW ............................154
FD60MWC .............................54
FD415M 	 ..............................54
FD430M 	 ..............................54
FD430MW ..............................54
FD460M 	 ..............................54
FD460MW ..............................54
FD Decorator Series ................54
FF2H 	
..............................55
FF4H 	
..............................55
FF5M 	
..............................55
FF5MH 	 ..............................55
FF6H 	
..............................55
FF6HH 	 ..............................55
FF12HC 	 ..............................55
FF12HHC 	 ..............................55
FF15MC 	 ..............................55
FF15MH 	 ..............................55
FF15MP 	 ............................154
FF30MC 	 ..............................55
FF30MH 	 ..............................55
FF30MP 	 ............................154
FF32H 	 ..............................55
FF32HH 	 ..............................55
FF34H 	 ..............................55
FF34HH 	 ..............................55
FF36H 	 ..............................55
FF46H 	 ..............................55
FF60MC 	 ..............................55
FF60MHC	 .............................55
FF60MP 	 ............................154
FF312H 	 ..............................55
FF312HH 	 ..............................55

FF315M 	 ..............................55
FF330M 	 ..............................55
FF360M 	 ..............................55
FF412H 	 ..............................55
FF415M 	 ..............................55
FF430M 	 ..............................55
FF460M 	 ..............................55
FF Commercial Series .............55
FM1D14-12U .........................22
FM1D14-24U .........................22
FM1D14-AV-U ........................22
FM1D14 Series .......................22
FM1D20-24U* ........................24
FM1D20-120U .......................24
FM1D20-240U .......................24
FM1D20A-24* ........................24
FM1D20A-120 .......................24
FM1D20A-240 .......................24
FM1D20E-24* ........................24
FM1D20E-120 .......................24
FM1D20E-240 .......................24
FM1D20 Series .......................24
FM1D50-12U .........................23
FM1D50-24U .........................23
FM1D50-120U .......................23
FM1D50-240U .......................23
FM1D50A-12 .........................23
FM1D50A-24 .........................23
FM1D50A-120 .......................23
FM1D50A-240 .......................23
FM1D50E-12 .........................23
FM1D50E-24 .........................23
FM1D50E-120 .......................23
FM1D50E-240 .......................23
FM1D50 Series .......................23
FM1QTUZ-120U .....................42
FM1QTUZH-24U .....................42
FM1QTUZH-120U ...................42
FM1QWUZ-120U ....................42
FM1QWUZ-240U ....................42
FM1QWUZH-120U ..................42
FM1QWUZH-240U ..................42
FM1QWUZH-BW-24U .................
FM1QWUZH-BW-24U* ............42
FM1S12HU-120U ...................40
FM1 Series .............................42
FM1STUZ-24U ........................42
FM1STUZ-120U ..........................
FM1STUZ220/50 ....................42
FM1STUZ-240U ......................42
FM1STUZH-24U .....................42
FM1STUZH220/50 ..................42
FM1STUZH-240U ...................42
FM1SWUZ-24U ......................42
FM1SWUZ-120U ....................42
FM1SWUZ-240U ....................42
FM1SWUZH-24U ....................42
FM1SWUZH-120U ..................42
FM1SWUZH-240U ..................42
FM2D50-24 ...........................22
FM2D50-120 .........................22
FM2D50-240 .........................22
FM2D50 Series .......................22
FM-FU 	 ............................153
FM-SU 	 ............................153
FWZ53 	 ..............................80
FWZ53-24U ...........................80
FWZ53-120/50U ....................80
FWZ53-120U .........................80
FWZ53-220/50U ....................80
FWZ53 Series .........................80
FWZ55 	 ..............................80
FWZ55-120U .........................80
FWZ55-220/50 ......................80
FWZ55K-120U .......................80
FWZ55K-220/50 ....................80
FWZ55K-240U .......................80
FWZ55 Series .........................80
FWZ72-24U ...........................81
FWZ72-120U .........................81
FWZ72B-120U .......................81
FWZ72B-240U .......................81
FWZ72C-120 .........................81
FWZ72K-240U .......................81
FWZ72 Series .........................81
FWZ72 Series Gasket ..............81

G

G-53U 	 ..............................80
G-55U 	 ..................... 80, 153
G-72U 	 ..................... 81, 153
G8000 Series .........................88
G8045-00 	..............................88
G8045-20 	..............................88
G8145-00 	..............................88
G8145-20 	..............................88
GM40AV 	 ..............................29
GM40AVE 	..............................20
GM40AV-M ............................29
GM40AV-Q .............................29
GM40AV-QW ..........................29
GM40AV-W ............................29
GMX2FM2D50I-24 .................21
GMX2FM2D50I-120 ...............21
GMX2FM2D50I-240 ...............21
GMX2FM2D50O-120 ..............21
GMX121-O-120* ....................40
GMX894-I-120 .......................19
GMX894-O-120 .....................19
GMXFM1D20-I-24 ..................21
GMXFM1D20-I-120 ................21
GMXFM1D20-I-240 ................21
GMXFM1D20-O-24 .................21
GMXFM1D20-O-120 ...............21
GMXFM1D20-O-240 ...............21
GMXFM1D50-I-12 ..................21
GMXFM1D50-I-24 ..................21
GMXFM1D50-I-120 ................21
GMXFM1D50-I-240 ................21
GMXFM1D50-O-12 .................21
GMXFM1D50-O-120 ...............21
GMX/FM1 Series .....................21
GMXQT-I-120 .........................43
GMXQT-O-120 .......................43
GMXQW-I-240 ........................43
GMXQW-O-120 ......................43
GMX Series ............................43
GMXST-I-120 .........................43
GMXST-I-240 .........................43
GMXST-O-24 ..........................43
GMXST-O-120 ........................43
GMXST-O-240 ........................43
GMXSW-I-24 ..........................43
GMXSW-I-240 ........................43
GMXSW-O-24 ........................43
GMXSW-O-120 ......................43
GMXSW-O-240 ......................43
GZ40AU 	 ..............................84
GZ40BU 	 ..............................84
GZ52BU 	 ..............................84

H

HB110 Series .........................58
HB112 	 ..............................58
HB113 	 ..............................58
HB114 	 ..............................58
HB880R 	 ..............................59

I

IG1C3R 	 ............................103
IG1CM 	 ............................103
IG1CM3R 	 ............................103
IG1C Spare ...........................103
IG2T3R 	 ............................102
IG2TM 	 ............................102
IG2T Spare ...........................103
IG4TM 	 ............................102
IG20B123 	............................101
IG1200RC3 .............98, 98, 143
IG1240FMP33 ........................99
IG1240RC3 ..................... 95, 98
IG1300-2T-1C3 ............... 95, 99
IG1300-4T-1C3 ......................99
IG1300-4T-2C3 ............... 95, 99
IG2012B153 ........................101
IG3240FMP33 ........................99
IG3240RC3 ..................... 95, 98
IG20663 	 ............................101
IG112463 	............................101
IG112663 	............................101
IG112663BLK10 ...................101
IG206153 	............................101
IG Flush Mount Kit .................103
IOS-CMP-LV ...........................74

IOS-CMP-U .............................74
IOS-DDR Series ......................75
IOS-DDR-WH ..........................75
IOS-DOV-IV .............................75
IOS-DOV-NL-IV .......................75
IOS-DOV-NL-WH .....................75
IOS-DOV Series ......................75
IOS-DOV-WH ..........................75
IOS-DPBIF2-IV ........................76
IOS-DPBIF2 Series ..................76
IOS-DPBIF2-WH ......................76
IOS-DPBIF-IV ..........................77
IOS-DPBIF Series ....................77
IOS-DPBIF-WH ........................77
IOS-DPBIMF-IV .......................77
IOS-DPBIMF Series .................77
IOS-DPBIMF-WH .....................77
IOS-DSIF-IV ............................76
IOS-DSIF Series ......................76
IOS-DSIF-WH ..........................76
IOS-DSIMF-IV .........................76
IOS-DSIMF Series ...................76
IOS-DSIMF-WH .......................76
IOS-DSR-IV .............................75
IOS-DSR Series .......................75
IOS-DSR-WH ..........................75
IOS-HB-U 	 ..............................74
IOS-PP24 	..............................74

K

K42-SW-A ..............................71
K121 	
..............................71
K121-30 	 ..............................71
K122 	
..............................71
K1100 Series .........................72
K1121 	 ..............................72
K1122 	 ..............................72
K1200 Series .........................72
K1221 	 ..............................72
K1222 	 ..............................72
K4000C Series .......................68
K4021C 	 ..............................68
K4023C 	 ..............................68
K4027 	 ..............................68
K4035 	 ..............................68
K4100 Series .........................69
K4121C 	 ....................... 36, 69
K4123C 	 ..............................69
K4127 	 ..............................69
K4135 	 ..............................69
K4136M 	 ..............................69
K4141C 	 ..............................69
K4200 Series .........................70
K4221C 	 ..............................70
K4223C 	 ..............................70
K4227 	 ..............................70
K4235 	 ..............................70
K4236C 	 ..............................70
K4251 	 ..............................70
K4253 	 ..............................70
K4321C 	 ..............................68
K4400 Series .........................69
K4421M 	 ..............................69
K4423M 	 ..............................69
K4500 	 ..............................71
K4500 Series .........................70
K4521 	 ..............................70
K4522 	 ..............................70
K4524 	 ..............................70
K4533 	 ..............................70
K4535 	 ..............................70
K4536SS 	 ..............................73
K4536SST ..............................73
KM2 Series .............................56
KM2ST-1G .............................56
KM2ST-2D .............................56
KM2ST-2G .............................56
KM2ST-2R ..............................56
KM2ST-3D .............................56
KM2ST-3G .............................56
KM2ST-4G .............................56
KM2STU-1G ...........................56

L

LC2000 	 ..............................72
LC2000 Series .......................72
LC4500 Series .......................71

www.intermatic.com

LC4521C 	 ..............................71
LC4521LA ..............................71
LC4523 	 ..............................71
LC4523LA ..............................71
LC4527 	 ..............................71
LC4535 	 ..............................71
LC4535LA ..............................71
LC4536C 	 ..............................71
LC4536LAC ............................71
LM2-0-882T ..........................64
LM2-O-120 ............................65
LM2-O-882T ..........................64
Low Voltage Power Packs ........46
LS1 	
..............................67
LS2 	
..............................67
LS2 Sensor ...................... 64, 65
LS Series 	 ..............................67

M

MB-48V 	 ............................153
MB-DIN 	 ..................... 22, 153
MIL72AQTUZ-120 ..................44
MIL72AQTUZ-240 ..................44
MIL72AQTUZH-24* .................44
MIL72AQTUZH-120 ................44
MIL72AQWUZ-120 .................45
MIL72AQWUZH-24* ................45
MIL72AQWUZH-120 ...............45
MIL72AQWUZH-240 ...............45
MIL72ASTUZ-24 .....................44
MIL72ASTUZ-120 ...................44
MIL72ASTUZ220 ....................44
MIL72ASTUZ-240 ...................44
MIL72ASTUZH-24 ...................44
MIL72ASTUZH-120 .................44
MIL72ASWUZ-24 ....................45
MIL72ASWUZ-120 ..................45
MIL72ASWUZ-240 ..................45
MIL72ASWUZH-24 .................45
MIL72ASWUZH-120 ...............45
MIL72ASWUZH-240 ...............45
MIL72EQTUZ-24* ...................44
MIL72EQTUZ-120 ...................44
MIL72EQTUZ-240 ...................44
MIL72EQTUZH-24* .................44
MIL72EQTUZH-120 .................44
MIL72EQWUZ-120 ..................45
MIL72EQWUZH-24* ................45
MIL72EQWUZH-120 ...............45
MIL72EQWUZH-240 ...............45
MIL72ESTUZ1A240 ................44
MIL72ESTUZ-24 .....................44
MIL72ESTUZ-120 ...................44
MIL72ESTUZ-240 ...................44
MIL72ESTUZH-24 ...................44
MIL72ESTUZH-120 .................44
MIL72ESTUZH220 ..................44
MIL72ESTUZH-240 .................44
MIL72ESWUZ-24 ....................45
MIL72ESWUZ-120 ..................45
MIL72ESWUZH-24 ..................45
MIL72ESWUZH-120 ................45
MIL72ESWUZH-240 ................45
MIL72 Series ................... 44, 45
ML44T 	 ..............................46
ML88T 	 ..............................46
ML100THB .............................46
ML121RT 	..............................46
ML200RT 	..............................46
ML200RTW ............................46
ML300RTW ............................46
ML300RTWSN ........................46
ML600TW 	..............................46
ML600TWSN ..........................46
ML814DRP .............................46
ML900TW 	..............................46
ML900TWSN ..........................46
Mounting Brackets ................150
MultiWave Control System .....114

N

NE1C 	

P

..............................69

P1000 	 ............................137
P1100 Series .......................139
P1101 	 ............................139

P1103FE 	 ............................137
P1121 	 ............................139
P1131 	 ............................139
P1200 Series .......................139
P1251P 	 ............................139
P1261P 	 ............................139
P1353ME 	............................120
P1403ME 	............................119
P4043ME 	............................118
P4243ME 	............................118
P7000 	 ............................137
P7103ME 	............................137
PA102 	 ............................154
PA114 	 ................... 141, 154
PA115 	 ............................152
PA117 	 ............................154
PA120 	 ............................154
PA122 	 ................... 115, 154
PA600 	 ................... 144, 154
PB300 Series .......................136
PB313E 	 ............................136
PB313EK 	 ................... 136, 154
PB314E 	 ............................136
PB314EK 	 ............................154
PB314EK* 	............................136
PB373E 	 ............................136
PB374E 	 ............................136
PB800 	 ............................138
PB873MKZ ...........................138
PB900 	 ............................138
PB913N 	 ............................138
PB913N66 .................. 138, 154
PB913N84 ...........................138
PB914N 	 ............................138
PB914N66 ...........................138
PB914N84 ...........................138
PC1-120 	 ..............................67
PC1-120-LS1 .................. 66, 67
PC1-120-LS2 .........................66
PC2-120 	 ..............................67
PC2-120-LS1 .................. 66, 67
PC2-120-LS2 .........................66
PC Series 	..............................66
PE24VA 	 ............................141
PE100 Series ........................121
PE103 	 ............................119
PE140 	 ............................118
PE153 	 ............................121
PE153F 	 ............................121
PE153P 	 ............................121
PE153PF 	 ............................121
PE650 	 ............................154
PE653 	 ................... 115, 154
PE653RC 	 ............................114
PE953 	 ................... 115, 154
PE1403ME ...........................119
PE10000 	 ................... 122, 144
PE10000 Series ....................122
PE15300 	 ............................122
PE15300F 	............................122
PE20000 	 ............................122
PE20000RC Series Kits .........116
PE20000 Series ....................122
PE20065RC .........................116
PE24065RC .........................116
PE25300 	 ............................122
PE25300F 	............................122
PE30000 	 ............................123
PE30000RC .........................117
PE30000 Series ....................123
PE30000T3 ..........................123
PE30065RC .........................117
PE34065RC .........................117
PE35300 	 ............................123
PE40000 	 ............................123
PE40000 Series ....................123
PE45300 	 ............................123
PF1100 	 ............................133
PF1100 Series ......................132
PF1102 	 ............................132
PF1102M 	............................132
PF1102MT ...........................132
PF1102T 	 ............................132
PF1103 	 ............................132
PF1103M 	............................132
PF1103MT ...........................132
PF1103T 	 ............................132
PF1112T 	 ............................133

7

PF1200 	 ............................133
PF1202T 	 ............................133
PF1222TB1 ..........................133
PJB2175 	 ................... 141, 154
PJB4175 	 ................... 141, 154
PJB Series ............................141
Plastic In-Use Covers ..................
108, 109, 110, 111
PS3000 	 ............................143
PX50 	
............................130
PX50S 	 ............................130
PX100 	 ............................130
PX100S 	 ............................130
PX300 	 ............................130
PX300S 	 ............................130
PX600 	 ............................130
PX600S 	 ............................130

R

R8800 		 ..............................39
R8806M101C ........................39
R8806P101C .........................39
R8815P101C .........................39
R8816P101C .........................39
RC4G 	 ............................134
RC6F 	
............................134
RC117 	 ................... 134, 154
RC122B 	 ................... 134, 154
RC127B 	 ................... 134, 154
RC150 	 ................... 134, 154
RC510 	 ................... 134, 154
RC600 Series .......................140
RC613 	 ............................140
RC613L 	 ............................140
RC613R 	 ............................140
RC615 	 ............................140
RC939 	 ............................140
RC2000 Series .....................135
RC2100 Series .....................135
RC2103S 	 ............................134
RC2123PT ...........................135
RC2163BE ...........................135
RC2163BFE ..........................135
RC2343PT ...........................135
RC Series 	............................134
RZ52HU 	 ..............................85
RZ52VU 	 ..............................85
RZ Series 	 ..............................85

S

ST01 	
ST01A 	

T

..............................50
..............................50

T100M Series .......................124
T100 Series ................... 32, 125
T101 	
..............................32
T101B 	 ..............................32
T101M 	 ..................... 32, 124
T101P 	 ..............................32

T101P3 	 ............................125
T101P201 ............................125
T101PCD82 ...........................32
T101R 	 ..............................32
T101R3 	 ............................125
T101R201 ............................125
..............................32
T102 	
T102P 	 ..............................32
T102R 	 ..............................32
T103 	
..............................32
T103M 	 ..................... 32, 124
T103P 	 ..............................32
T103PCD82 ...........................32
T103R 	 ..............................32
T104 	
..............................32
T104-20 	 ..............................41
T104-50 	 ..............................32
T104M 	 ..................... 32, 124
T104M201 ...........................124
T104P 	 ..............................32
T104P3 	 ............................125
T104P201 ............................125
T104PCD82 ...........................32
T104R 	 ..............................32
T104R3 	 ............................125
T104R201 ............................125
T105 ** 	 ..............................32
T106M 	 ..................... 32, 124
T106P3 	 ............................125
T106R** 	 ..............................32
T170 Series ............................33
T171 	
..............................33
T171CR 	 ..............................33
T172 	
..............................33
T173 	
..............................33
T173CR 	 ..............................33
T173R 	 ..............................33
T174 	
..............................33
T174CR 	 ..............................33
T174R 	 ..............................33
T175** 	 ..............................33
T176 	
..............................33
T1400 Series ..........................33
T1471BCR .............................33
T1471BR 	 ..............................33
T1472BR 	 ..............................33
T1475BR 	 ..............................33
T1800 Series ..........................33
T1871BR 	 ..............................33
T1900 Series ..........................34
T1905 	 ..............................34
T1905E 	 ..............................34
T1905HD 	..............................35
T1905P 	 ..............................34
T1906 	 ..............................34
T1970 Series ..........................34
T1975 	 ..............................34
T1975E 	 ..............................34
T1975EHD .............................35
T1975ER 	 ..............................34

Model #	

Page

Cycle Timers
CT2000 Series.......................25
Defrost Timers
DTAV40 Series..................89, 91
G8000 Series.........................88
Electronic Time Switch
ET1100 Series........................17
ET1700 Series........................17
	ET8000 Series........................17
ET90000 Series......................13
General Purpose ON/OFF Time Switches
GM40AV Series................20, 29
GMXS Series..........................43
T100 Series...... 32, 41, 124, 125
T1900HD Series...............34, 35
T74000B Series......................37
Hour Meters
FWZ Series.......................80, 81
RZ Series	 ..............................85
UWZ Series.......................82,83

8

T1975R 	 ..............................34
T1976 	 ..............................34
T1976R 	 ..............................34
T2000 Series ..........................37
T2005 	 ..............................37
T2006 	 ..............................37
T7000B Series .......................37
T7401B 	 ..............................37
T7401BC 	 ..............................37
T7401BCR .............................37
T7402B 	 ..............................37
T7402BC 	 ..............................37
T7801B 	 ..............................37
T7801BC 	 ..............................37
T7802B 	 ..............................37
T8800 Series ..........................39
T8805M101C .........................39
T8805P101C .........................39
T8845PV 	 ..............................39
T10000R 	 ............................126
T10000R Series ...................126
T10000RT ............................131
T10004R 	 ............................126
T10004RT1 ..........................131
T10004RT3 ..........................131
T10006R 	 ............................126
T10101R 	 ............................126
T10404R 	 ............................126
T10604R 	 ............................126
T12404R 	 ............................126
T20000R Series ...................127
T21000R 	 ............................127
T21001R 	 ............................127
T21004R 	 ............................127
T30000R5 ............................128
T30000R Series ...................128
T30004R 	 ............................128
T30401R 	 ............................128
T30404R 	 ............................128
T30604R 	 ............................128
T32404R 	 ............................128
T40000R 	 ............................129
T40000R4 ............................129
T40000R Series ...................129
T40000RT ............................131
T40000RT3 ..........................131
T40003RT3 ..........................131
T40004R 	 ............................129
T40004RT1 ..........................131
T40004RT3 ..........................131
T40404R 	 ............................129
T50000 Series ........................36
T51211BC .............................36
T51311BC .............................36
Talento 121 ............................40
TALENTO121-120 ..................40
TALENTO121-240 ..................40
Talento 800 Series ..................19
Talento 882 ..................... 18, 19
Talento891-24 ........................19

Talento892-24 ........................19
Talento894-24 ........................19
Talento894-120 ......................19
TalentoPro 	..............................18
Talento Taxxi ...........................19
TalentoTaxxi-P ........................19
TN111RM40 ..........................59
TN311 	 ..............................59
Type 1 Enclosure ..................148
Type 1 Rated Enclosure .........150
Type 3R Rainproof
Enclosures .. 148, 149

U

UWZ48-24U ...........................82
UWZ48-240U .........................82
UWZ48A-24U .........................82
UWZ48A Series ......................82
UWZ48E-24/50U ....................83
UWZ48E-24U .........................83
UWZ48E-120/50U ..................83
UWZ48E-120U .......................83
UWZ48E-220/50U ..................83
UWZ48E-240U .......................83
UWZ48E Series .......................83
UWZ48 Series ........................82
UWZ48V-24U .........................83
UWZ48V-120U .......................83
UWZ48V Series ......................83
UWZ52E-120U .......................83
UWZ52E Series .......................83
UWZ248-120U .......................82
UWZ248A-120U .....................82

V

V45000 Series .......................41
V45471CR34 .........................41
V45471CR42 .........................41
V45471R30 ...........................41
V45471R34 ...........................41
V45471R42 ...........................41
V45472CR30 .........................41
V45472CR34 .........................41
V45472CR42 .........................41
V45472R30 ...........................41
V45472R34 ...........................41
V45472R42 ...........................41
Vapor Tight Fixtures .................92
VPKG-11-CGI .........................92
VPXG-11-CGI .........................92
VWG-01-CGI ..........................92

W

WG190-15D .........................153
WG433-20D .........................153
WG436-20 ...........................153
WG630D 	 ............................153
WG720-10D .........................153
WG730-14D .........................153
WG733-14D .........................153

HVACR Products
Model #	

Page

HVAC Surge
AG3000 Series.........95, 97, 143
In-Wall Countdown Timers
EI200 Series...........................53
EI400 Series...........................52
FF/FD Series.............54, 55, 154
In-Wall Mechanical Timers
KM2ST Series.........................56
In-Wall Programmable Timers
EI500 Series...........................49
EI600 Series...........................48
ST01 Series............................50
Plug-In and Appliance Timers
DT620 	 ..............................59
HB Series	..............................58
TN311C	 ..............................59

Model #	

WG736-14D .........................153
WG750-10 ...........................153
WG760-10 ...........................153
WG770-10 ...........................153
WG770-10D .........................153
WG773-10 ...........................153
WG780-12D .........................153
WG790-11D .........................153
WG1380-11 .........................153
WG1383-11 .........................153
WG1570-10D .......................152
WG1571-10D .......................153
WG1573-10D .......................152
WG1574-10D .......................153
WG1576-10D .......................153
WG1600-11 .........................153
WG1603-11D .......................153
WH21 	 ..............................41
WH40 	 ..............................41
WHAVQ4 	 ..............................28
WHAVQ7 	 ..............................28
WHAVQ Series ........................28
WP17 	 ................... 106, 107
WP101 	 ................... 106, 110
WP102 	 ................... 106, 110
WP107 	 ............................106
WP213 	 ............................106
WP217 	 ................... 106, 107
WP1000C 	............................109
WP1000GC ..........................109
WP1000HC ..........................109
WP1000HGC ........................109
WP1000WC .........................109
WP1010C 	............................109
WP1010HC ..........................109
WP1010HMXD .....................107
WP1010MXD .......................107
WP1020C 	............................110
WP1020GC ..........................110
WP1020WC .........................110
WP1030C 	............................110
WP1030MXD .......................107
WP1050 	 ............................110
WP1100C 	............................108
WP1100WC .........................108
WP1110C 	............................108
WP1110GC ..........................108
WP1110WC .........................108
WP1150C 	............................111
WP1220C 	............................111
WP1220GC ..........................111
WP1220WC .........................111
WP1230C 	............................111
WP1250C 	............................111
WP1250MVXD ......................107
WP1250MXD .......................107
WP3100C 	............................108
WP3103C 	............................108
WP3110MXD .......................107

Page

Timer Modules
FM1 Series..... 22, 23, 24, 40, 42
FMD Series.......................22, 23
MIL72 Series....................44, 45
Talento Pro Series.......18, 19, 21
Vapor Tight Freezer Lighting Fixtures
VPKG-11-CGI .........................94
VPXG-11-CGI .........................92
VWG-01-CGI ..........................94
Water Heater Time Switches
EH40 Series...........................25
WH40 Series..........................41
WHAV Series..........................28

Electronic
Time Switches

Air Conditioners
Office Lighting
Signs

Bell Ringing
Water Heaters

Parking Lot Lighting

Ventilation Systems
Outdoor Lighting

B i l l boards

Electronic Time Switches

Building Automation
Systems (BAS)
Energy savings has become an international currency.
Industries and businesses around the world are looking for practical and
cost-effective methods to save energy and money. That’s why Intermatic is
taking the initiative to help your business use energy efficiently and ultimately
save money with its Building Automation System (BAS) solutions.
These systems provide practical energy saving solutions for
businesses across the globe. They help centralize energy management
controls in buildings to maximize efficiency and performance.
Building automation systems integrate existing energy controls into energy
conscious solutions. This is a vital part of reducing energy consumption. Most
energy control products are designed to outdo the competition and not serve the
business. Intermatic’s BAS solutions are designed to meet the customer needs
today and in the future.

Why waste another dollar on inefficient energy control systems?
Let Intermatic give you the cost-effective solutions for your building.

Common Components Controlled by a Building Automation System

10

• Indoor Lighting

• Pump Controls

	

• Signals/Alarms

• Outdoor Lighting

• Irrigation Controls

	

• Security Controls

• HVACR Equipment

• Water Heating Equipment

	

• Food Preparation

Restaurant

Retail

ET90000
Service

Signage

Alarm

Electronic Time Switches

I ma g i n e a l l t he Possi bi l i t i e s

Lobby

Outdoor Lighting

Facilities

Educational

Parking Area

Offices
www.intermatic.com

11

Electronic Time Switches
12

Introducing the New
ET90000 Series Energy Controls

The ET90000’s USB connection and Ethernet capabilities enable
in-field schedule updates and firmware upgrades to be installed
from one central location.

Electronic Time Switches

Are you tired of stopping at every timer
to update software?

ET90000 Series

365-Day Astronomic Time Switches
• Automatically detects input voltages between 120 and 277 VAC
• Up to 4,000 events plus holidays scheduling
• USB connection for easy program transfer, schedule backup, and firmware updates
• Ethernet capable for upgrading firmware and networking time switches and PC tools
• Up to 8 external overrides for remote circuit control
• 100+ hour supercapacitor maintains date and time in case of power outage
• Easy-to-follow on-screen menu
• Supports relative dates, such as “4th Thursday of November”
• Password protection
• Firmware upgradeable
• Schedule review mode
• Saved activity log
Model #

Circuits

Enclosure

Ethernet

ET90115C

1

Type 1 Steel

Optional

12-240 VAC

ET90115CE

1

Type 1 Steel

Included

10 A

12-240 VAC

ET90115CR

1

Type 3R Steel

Optional

20 A

10 A

28 VDC

ET90115CRE

1

Type 3R Steel

Included

Inductive Ballast

20 A

3A

120-277 VAC

ET90115M*

1

—

Optional

Tungsten

5A

—

12-120 VAC

ET90215C

2

Type 1 Steel

Optional

Pilot Duty

470 VA

275 VA

120-240 VAC

ET90215CE

2

Type 1 Steel

Included

Motor

1 HP

¼ HP

120 VAC

Type 3R Steel

Optional

Motor

2 HP

½ HP

240 VAC

ET90215CR

2

ET90215CRE

2

Type 3R Steel

Included

ET90215M*

2

—

Optional

ET90415CR

4

Type 3R Steel

Included

ET90815CR

8

Type 3R Steel

Included

ET91215CR

12

Type 3R Steel

Included

ET91615CR

16

Type 3R Steel

Included

Load Type

Normally
Open N.O.

Normally
Voltage
Closed N.C.

General Purpose & Resistive

30 A

—

General Purpose & Resistive

20 A

Resistive

Ratings:

Note: The electronic mechanism snaps into the standard Intermatic enclosure for easy upgrading of
mechanical mechanisms, if desired.
Cycle: 50/60 Hz.
Wiring Terminals: #20 to #6 AWG wire
Min. ON/OFF Times: 1 second
Max. ON/OFF Times: 365 days
Operating Temperature: -40°F to 104°F (-40°C to 40°C)
Warranty: Limited 1 year

www.intermatic.com

*Replacements for 1 & 2 circuits only
See Replacement Enclosures 2T2040GA & 2T511GA on Page 148

13

Electronic Time Switches

Control Your ET90000 Remotely!
NEW

The new ET90000 PC Application gives you remote control of your device
from any location. Gain real-time remote control of circuits, perform
firmware updates, or download events, zones, and holidays anywhere! The
PC App is great for creating schedules before, during, or after installation.

ET90000 Series Accessories

The ET9100 Replacement Door Assembly
includes a display, keypad, Ethernet, and
remote override connections. The door
assembly can be replaced without
installing a new panel or rewiring any circuits.
The replacement door is for use with the
ET90415CR, ET90815CR, ET91215CR, and
ET91615CR.

14

Extend the versatility of the ET90000 series
with remote control over Ethernet. This
module can be used as an upgrade or
replacement part to enable ET90000 series
controllers to be configured, monitored, and
controlled remotely with software for the PC.
Works with all ET90000 models.

The ET9250 Relay Module can be used as a
replacement part or for upgrading the number
of circuits in the ET90000 controller. The relay
module comes in 4-circuit packs for
upgrading to a maximum of 16 circuits. Each
module includes four SPDT 30 Amp
relays, to be used with ET90415CR,
ET90815CR, ET91215CR, and ET91615CR.

Model #

Description

Model #

Description

Model #

Description

ET9100

Door Assembly

ET9232

Ethernet Module

ET9250

Relay Module

The ET8415 7-Day Astronomic Time Switch is the ultimate tool for energy
management. Complete with 4-circuit control to cover different areas of your
facility, the ET8415 features easy-to-use, to-the-minute programming for
reduced energy costs. Just name the application and the ET8415CR is in
tune with your facility demands.

NEW

Electronic Time Switches

Manage Intuitively

ET8415CR

7-Day Astronomic Time Switch
• Automatically adjusts voltages between
120 and 277 VAC, 50/60Hz
•5
 6 ON/OFF events per week
 astronomic events
•8
•1
 00+ hour supercapacitor maintains time and date
after power loss
• To-the-minute accuracy
•T
 emporary override or permanent manual override
• Automatic Daylight Saving Time adjustment
Model #

Circuits

Enclosure

ET8415CR

4 x SPST

Type 3R Steel Indoor/Outdoor

Ratings:

Note: The electronic mechanism snaps into Intermatic enclosure 2T511GA, replacing
mechanical mechanisms, if desired.
Input Voltage: 120/208/240/277 VAC
Cycle: 50/60 Hz.
Switch Rating: 30 Amp Inductive/Resistive, 120, 240 VAC, 20 Amp Resistive, 28 VDC, 1
HP, 120 VAC, 2 HP, 240 VAC, 5 Amp Tungsten, 120-240 VAC, 20 Amp Ballast, 120-277 VAC
Wiring Terminals: #18 to #10 AWG wire
Min. ON/OFF Times: 1 minute
Max. ON/OFF Times: 6 days 23 hours 59 minutes
Warranty: Limited 1 year

Common ET8415 Applications
• Indoor Lighting

• Bell Ringing

• Gas Stations

• Outdoor Lighting

• Billboard Lighting

• Security Lighting

www.intermatic.com

15

Electronic Time Switches

Meet Your New Time Switch!
Our mission is to help you find the ET Series time switch that meets your demands.
Simply create your time switch profile in 3 easy steps and then find your perfect match.
The versatile 24-Hour, 7-Day ET series time switches feature one SPST circuit, one SPDT
circuit, or two SPST circuits. They can be installed in an indoor or rainproof enclosure or
shipped as a mechanism only.
You name the application and we’ll deliver the practical solution for you!

Find Your Time Switch
Match in 3 Easy Steps!

1

Choose your schedule from these options:	
24-Hour
7-Day
7-Day Astronomic

2

Choose your circuit/switch type from these options:	
One SPST Circuit

One SPDT Circuit

Two SPST Circuits

3

Choose your enclosure from these options:
Indoor Type 1 Steel
Outdoor Type 3R Plastic
Outdoor Type 3R Steel
Mechanism Only
Find the time switch that matches your profile from the table on the next page!

16

Electronic Time Switches

Outdoor Type 3R Steel

Outdoor Type 3R Plastic

Indoor Type 1 Steel

ET Series

Time Switches
•
•
•
•
•
•

Automatic Daylight Saving Time adjustment
T
 emporary and permanent manual overrides
To-the-minute programming accuracy
F
 ield-replaceable 3-year battery backup
Astronomic programming can be combined with independent programs to provide a sunset ON and time OFF program
28 setpoints (14 ON/OFF per channel)

24-Hour Schedule

7-Day Schedule

1 Circuit SPST Switch
Model #

1 Circuit SPST Switch

Enclosure

ET1105CM

–

ET1105C

Indoor Type 1 Steel

ET1105CPD82
ET1105CR

Outdoor Type 3R Plastic
Outdoor Type 3R Steel

Model #

ET1115C

–
Indoor Type 1 Steel

ET1115CPD82
ET1115CR

Outdoor Type 3R Plastic
Outdoor Type 3R Steel

ET1705C
ET1705CPD82
ET1705CR

ET1125C
ET1125CPD82
ET1125CR

ET8015C

–

ET1715C

Indoor Type 1 Steel

ET1715CPD82
ET1715CR

–

Outdoor Type 3R Plastic
Outdoor Type 3R Steel

Indoor Type 1 Steel
Outdoor Type 3R Plastic
Outdoor Type 3R Steel

Model #

ET8015CPD82
ET8015CR

–

ET1725C

Indoor Type 1 Steel

ET1725CPD82
ET1725CR

Outdoor Type 3R Plastic
Outdoor Type 3R Steel

Model #

Enclosure

ET8115CM
ET8115C

–
Indoor Type 1 Steel

ET8115CPD82
ET8115CR

Outdoor Type 3R Plastic
Outdoor Type 3R Steel

2 Circuits SPST Switch

Enclosure

ET1725CM

–
Indoor Type 1 Steel

1 Circuit SPDT Switch

Enclosure

ET1715CM

Enclosure

ET8015CM

2 Circuits SPST Switch

Enclosure

ET1125CM

Outdoor Type 3R Plastic
Outdoor Type 3R Steel

Model #

2 Circuits SPST Switch
Model #

–
Indoor Type 1 Steel

Model #

1 Circuit SPDT Switch

Enclosure

ET1115CM

1 Circuit SPST Switch

Enclosure

ET1705CM

1 Circuit SPDT Switch
Model #

7-Day Schedule Astronomic

Outdoor Type 3R Plastic
Outdoor Type 3R Steel

Model #

Enclosure

ET8215CM
ET8215C
ET8215CPD82
ET8215CR

–
Indoor Type 1 Steel
Outdoor Type 3R Plastic
Outdoor Type 3R Steel

See Accessories/enclosures on Page 146

Ratings:

Note: The electronic mechanism snaps into Intermatic time switch enclosure models 2T2040GA, 2T511GA, 2T2500GA, and 2T2926A, replacing mechanical mechanisms, if desired.
Input Voltage: 120/208/240/277 VAC
Cycle: 50/60 Hz.
Switch Rating: 30 A Inductive/Resistive, 120/240 VAC, 20 A Resistive, 28 VDC, 1 HP, 120 VAC, 2 HP, 240 VAC, 5 A Tungsten, 120/240 VAC, 20 A Ballast, 120-277 VAC
SPDT models Normally Open (NO), Normally Closed (NC) contact ratings: 20 A (NO), 10 A (NC) Resistive/Inductive, 120/240 VAC, 1 HP (NO), ¼ HP (NC), 120 VAC, 2 HP (NO), ½ HP (NC),
240 VAC, 5 A Tungsten (NO), 120/240 VAC, 20 A (NO), 3 A (NC) Ballast, 120-277 VAC
Simultaneous Feature: 2-circuit models can be configured for simultaneous (DPST) operation.
Pulse Feature: 2-circuit models feature 2-second pulse option for contactor and bell ringing applications
Wiring Terminals: #18 to #10 AWG wire
Min. ON/OFF Times: 1 minute
Max. ON/OFF Times: 23 hours 59 minutes for 24-Hour models, 6 days 23 hours 59 minutes for 7-Day models
Warranty: Limited 1 year

www.intermatic.com

17

Electronic Time Switches

Having Trouble Keeping Track
of Your Maintenance Schedule?

Count On The Pro
The Talento882 DIN Rail timer’s hour meter and service indicator keeps you in tune with
your application so you avoid costly service interruptions. Whether it’s a lighting panel,
boiler, water treatment control, irrigation pump, or other heavy-duty industrial
application, the Talento882 removes the guesswork from your service schedule.

NEW

TalentoPro

Digital DIN Rail Mount 365-Day Time Switch
with Intelligent Scheduling

#E10694

•C
 umulative load monitoring hour counter with service indicator
keeps track of runtime for maintenance schedules
• Automatically detects and adjusts input voltages
(24 VAC/VDC through 240 VAC)
• Non-volatile memory (EEPROM)
• Random program switching function
• Assignable external input for countdown, override, or pulse function
• Weekly, Annual, and Holiday program scheduling
(ON/OFF, Pulse, Cycle)
• Backlit LCD with load status indicator
• Automatic Daylight Saving Time adjustment
• Astronomic program scheduling (with OFF time capability)
• 400 memory spaces
• Replaceable battery provides backup with a 10-year carryover
• Shortest switching time: 1 second
• Manual switch: Automatic/Override/Fix ON/OFF
• Security features include lockable keypad cover and PIN code
• 2-circuit independent programming
• Optional PC Data transfer via IR remote interface (Talento Taxxi-P)
Model #

Circuts

Input Voltage

Talento882

2

24 VAC/VDC, 120-240 VAC, 50/60Hz

Ratings:

Power Consumption: 3.7 VA
Switch Type: Circuit 1 SPDT, Circuit 2 SPST
N.O. and N.C. Contacts: 240 VAC, 16 A Resistive, 10 A General Purpose, 10 A Tungsten,
8 A Ballast, Pilot Duty B300
Wire Connections: Screw Terminals for #16 to #10 AWG
Dimensions: 3.35" H x 1.38" W (85 mm H x 35 mm W)
Warranty: 1 year

18

Electronic Time Switches

Spending Too Much Time Updating Your Timers?

Hail the Talento Taxxi
Streamline the programming process in your facility with the Talento Taxxi
Dialog Set. Simply create schedules from your PC and then transfer the data
via the hand-held programmer to each Talento882 or Talento890 Series.

Remote Programming in 4 Easy Steps:
1. Load the CD-ROM into your PC.
2. Program your fixed, holiday, and astronomic schedules from your PC.
3. Transfer programs to the hand-held programmer.
4. Transfer programs at each Talento timer via the programmer’s
infrared interface.

Talento Taxxi

Remote PC Programmer
• Astronomic programming
•	Fixed and floating holidays
• Stores up to 4 independent schedules

Talento Taxxi includes:
• Windows-based software
• Hand-held programmer
• CD-ROM
• USB Interconnect cable

Model #

Description

Qty.

TalentoTaxxi

Hand-held remote programming tool for Talento890 Series

1

TalentoTaxxi-P

Hand-held remote programming tool for Talento882

1

Mechanism Only, DIN Rail Mounting
Model #

Circuits Input Voltage

Talento891-24*

1

Talento892-24*

2

24 VAC, 50/60 Hz

Talento894-120*

4

120 VAC, 50/60 Hz

Talento894-24*

4

24 VAC, 50/60 Hz

24 VAC, 50/60 Hz

Type 3R, Outdoor Enclosure Mounting
Model #

Circuits Input Voltage

GMX894-O-120*

4

120 VAC, 50/60 Hz

Type 1, Indoor Enclosure Mounting

Talento 800 Series

Model #

Circuits Input Voltage

Digital Din/Rail 365-Day Astronomic Timer Module

GMX894-I-120*

4

• Automatic Daylight Saving Time adjustment
•	Programmable pulse events from 1 second or longer
•	Cycle function is programmable for both total cycle duration
and ON duration in minutes or seconds
• Non-volatile memory (EEPROM)
• Astronomic programming (via PC data transfer)
• 400 program spaces

120 VAC, 50/60 Hz

*Limited stock available

Ratings:

Switch Type: SPDT
Switch Rating: 16 A Resistive, 250 VAC per circuit
Environmental Rating: -13ºF to 131ºF (-25ºC to 55ºC)
Mounting Surface: DIN Rail (Type 1 & 3R available)
Shortest Switching Time: 1 second

www.intermatic.com

#E10694

19

Electronic Time Switches

No Tools Required!
Mechanism Snaps Into Alternative Enclosures
Battery
Backup

Auto-Voltage
No Dip Switch

Manual
Override

Simple-to-Program

Heavy-Duty
40 Amp
Contacts
LED
Power and
Load Status
Indicators

Moisture Resistant
Circuit Board

Large Screw
Terminals

Ground Lug

GM40AVE

40 Amp Auto-Voltage
Time Switch

#E10694

• Automatically adjusts voltages between 120-277 VAC
• 24-Hour/7-Day flexible scheduling
•P
 ower and Status LED indicators
• DPDT Swiching Configuration (2 N.O. and 2 N.C. Contacts)
• 20 Setpoint programs
• Temporary Manual Override
• Lithium battery with 7-year carryover
• Type 3R enclosure with lockable hasp
• To-the-minute accuracy
• Heavy-duty 40 Amp contact rating

20

Model #

Input Voltage

Switch Type

Battery Backup

GM40AVE

120-277 VAC, 50/60 Hz

DPDT

Yes

Ratings:

N.O. Contacts:
40 A, Resistive, 120-277 VAC, 1 HP (16 FLA, 90 LRA), 120 VAC,
2 HP (12FLA, 52LRA), 208-277 VAC, 30A, Ballast, 120 VAC,
20 A, Ballast, 277 VAC, 15 A, Tungsten, 120 VAC
N.C. Contacts:
30 A, Resistive, 120-277 VAC, 1 HP (12 FLA, 30 LRA), 120 VAC,
2 HP (10 FLA, 30 LRA), 240 VAC, 2 A, Tungsten, 120 VAC, 10 A, Ballast, 277 VAC
Wiring Connections: Screw box lug terminals up to (1) #8 AWG wire
Operating Temperature: - 40ºF to 131ºF (-40ºC to 55ºC)
Operating Humidity: 0 to 95% RH, non-condensing
Electrical Life: 50,000 Operations at Full Load
Warranty: Limited 1 year
For enclosure dimensions, see Page 151

Electronic Time Switches

GMX/FM1 Series

#E10694

One and Two-Circuit
Electronic Time Switches

• 24-Hour or 7-Day applications
• Finger-safe terminals
• Manual Daylight Saving Time adjustment (D20 Models)
• Auto Daylight Saving Time adjustment (D50 Models)
• Manual override with load status indication
• GMXFM1D50 & GMX2DFM50 available in 7 languages:
English, German, French, Italian, Spanish, Dutch, and Portuguese
• Heavy-duty relay contacts for switching low or line voltage loads
• Enclosure provides space for field added contactor
or other accessories

A.

1 Circuit
Model #
A. GMXFM1D20-I-120

Input Voltage

Setpoint Programs Enclosure

Battery Backup Carryover

120 VAC, 50/60 Hz

20

Type 1 Indoor

7 years

GMXFM1D20-I-24

24 VAC/VDC, 50/60 Hz

20

Type 1 Indoor

7 years

GMXFM1D20-I-240

240 VAC, 50/60 Hz

20

Type 1 Indoor

7 years

GMXFM1D50-I-12

12 VAC/VDC, 50/60 Hz

50

Type 1 Indoor

3 years

GMXFM1D50-I-120

120 VAC, 50/60 Hz

50

Type 1 Indoor

3 years

GMXFM1D50-I-24

24 VAC/VDC, 50/60 Hz

50

Type 1 Indoor

3 years

GMXFM1D50-I-240

240 VAC, 50/60 Hz

50

Type 1 Indoor

3 years

GMXFM1D20-O-120

120 VAC, 50/60 Hz

20

Type 3R Outdoor

7 years

GMXFM1D20-O-24

24 VAC/VDC, 50/60 Hz

20

Type 3R Outdoor

7 years

GMXFM1D20-O-240

240 VAC, 50/60 Hz

20

Type 3R Outdoor

7 years

GMXFM1D50-O-12

12 VAC/VDC, 50/60 Hz

50

Type 3R Outdoor

3 years

GMXFM1D50-O-120

120 VAC, 50/60 Hz

50

Type 3R Outdoor

3 years

Model #

Input Voltage

GMX2FM2D50I-120

120 VAC, 50/60 Hz

50

Type 1 Indoor

3 years

GMX2FM2D50I-24

24 VAC/VDC, 50/60 Hz

50

Type 1 Indoor

3 years

GMX2FM2D50I-240

240 VAC, 50/60 Hz

50

Type 1 Indoor

3 years

GMX2FM2D50O-120

120 VAC, 50/60 Hz

50

Type 3R Outdoor

3 years

2 Circuit

Ratings:

Power Consumption: 4 VA
Switch Type:SPDT relay
Wiring Connections: S crew terminal connections
N.C. Contact:
16 A, 277 VAC, Resistive
8 A, 24 VDC
360 VA, 120 VAC, Pilot Duty

Setpoint Programs Enclosure

N.O. Contact
½ HP, 120 VAC
1 HP, 240 VAC
16 A, 277 VAC Resistive
12 A, 120 VAC, Ballast
8 A, 240 VAC, Ballast
720 VA, 240 VAC, Pilot Duty
360 VA, 120 VAC, Pilot Duty
600 W, 120 VAC, Tungsten
1000 W, 240 VAC,Tungsten

Battery Backup Carryover

Warranty: Limited 1 Year

For enclosure dimensions, see Page 151

www.intermatic.com

21

Electronic Time Switches

NEW
FM1D14 Series

One-Circuit Panel Mount

E10694

• 24-Hour or 7-Day applications
• 14 setpoint programs
• Simple-to-use programming
• Manual override with status indication
• Rechargeable battery backup with industry-leading
2500-Hour carryover
• 5 preset adjustable block programs

Ratings:

Model #

Input Voltage

FM1D14-12U

12 VDC

FM1D14-24U

24 VAC/VDC, 50/60Hz

FM1D14-AV-U

120-277 VAC, 50/60Hz

Power Consumption: 1.4 W
Switch Type: SPDT relay
N.O. Contact:
15A, 277 VAC, General Use
10 FLA, 60 LRA, 250 VAC
½ HP, 120 VAC, 1 HP, 250 VAC
1000 W, 120 VAC, Tungsten
8 A, 277 VAC, STD Ballast
B300 Pilot Duty
4.9 A ,120 VAC, Electronic Ballast

NOTE: Clear dust cover order #DC-FME

FM2D50 Series

N.C. Contact:
15 A, 277 VAC, General Use
10 FLA, 60 LRA, 250 VAC
½ HP, 120/240 VAC
12 A, 24 VDC, Resistive
8 A, 120 VAC, STD Ballast
Dimensions:
2.36" x 2.36" (60 mm x 60 mm)
Wiring Connections:
¼" quick connect terminals
Operating Temperature:
-40ºF to 131ºF (-40ºC to 55ºC)
(limited display function at -13˚F)
Warranty: 1-year limited

E10694

Two-Circuit
Surface and Flush Mount

Model #

Input Voltage

FM2D50-24

24 VAC/VDC, 50/60 Hz

FM2D50-120

120 VAC, 50/60 Hz

FM2D50-240

240 VAC, 50/60 Hz

For DIN rail mounting, order MB-DIN
(DIN Rail Mounting Base)
See Accessories on Page 153

22

• 24-Hour or 7-Day applications
• Screw terminals for #10 to #24 AWG
• Clear dust cover
• 50 setpoint programs
• Free weekday block formation
• Selectable languages: English, German, French,
Italian, Spanish, Portuguese, and Dutch
• Auto Daylight Saving Time adjustment
• Easy-to-follow menu driven programming
• Manual override with load status indication
• Battery backup with 3-year carryover
• Each circuit operates independently or combined
• Heavy-duty relay contacts for switching low or
line voltage loads

Ratings:

Power Consumption: 4 VA
Switch Type: 2x SPDT Relay
N.O. and N.C. Contact:
16 A, 277 VAC Resistive
½ HP, 120 VAC, 1 HP, 240 VAC
12 A, Ballast 120 VAC, 8A, Ballast 240 VAC
720 VA, 240 VAC Pilot Duty 360 VA, 120 VAC Pilot Duty
600 W, Tungsten, 120 VAC 100 W, Tungsten 240 VAC
Wiring Connection: Screw termials for #10 to #24 AWG
Warranty: 1 year

HVAC, pumps, lighting, and other
industrial and commercial equipment.

FM1D50 Series

One-Circuit Surface/DIN Rail
and Flush Mount

E10694

• 50 setpoint programs
• Free weekday block formation
• Selectable languages: English, German, French,
Italian, Spanish, Portuguese, and Dutch
• Auto Daylight Saving Time adjustment
• 24-Hour or 7-Day applications
• Easy-to-follow menu driven programming
• Manual override with load status indication
• Battery backup with 3-year carryover
• Heavy-duty relay contacts for switching
low or line voltage loads

A.

Electronic Time Switches

The FMD Series
modules are ideal for

A. Panel Mounting
Model #

Input Voltage

Clear Dust Cover

FM1D50-12U

12 VAC/VDC, 50/60 Hz

No

FM1D50-120U 120 VAC, 50/60 Hz

No

FM1D50-24U

No

24 VAC/VDC, 50/60 Hz

FM1D50-240U 240 VAC, 50/60 Hz

No

Note: Clear dust cover order DC-FME

B. Flush Mounting
Model #

Input Voltage

Clear Dust Cover

FM1D50E-12

12 VAC/VDC, 50/60 Hz

Yes

FM1D50E-120

120 VAC, 50/60 Hz

Yes

FM1D50E-24

24 VAC/VDC, 50/60 Hz

Yes

FM1D50E-240

240 VAC, 50/60 Hz

Yes

Model #

Input Voltage

Clear Dust Cover

FM1D50A-12

12 VAC/VDC, 50/60 Hz

Yes

FM1D50A-120

120 VAC, 50/60 Hz

Yes

FM1D50A-24

24 VAC/VDC, 50/60 Hz

Yes

B.

C. Surface/DIN Rail Mounting

FM1D50A-240 240 VAC, 50/60 Hz

Yes

Ratings:

Power Consumption: 4 VA
Switch Type: SPDT Relay	
N.O. Contact:
½ HP, 120 VAC
1 HP, 240 VAC
12 A, Ballast 120 VAC
8 A, Ballast 240 VAC
720 VA, 240 VAC Pilot Duty
360 VA, 120 VAC Pilot Duty
600 W, Tungsten 120 VAC
1000 W, Tungsten 240 VAC

N.C. Contact:
16 A, 277 VAC Resistive			
8 A, 24 VDC
360 VA, 120 VAC Pilot Duty
Dimensions:
FM1D50A 2.83" W x 4" H (72 mm x 102.5 mm)
FM1D50E 2.83" W x 4" H (72 mm x 102.5 mm)
FM1D50 2.36" W x 2.36" H (60 mm x 60 mm)
Wiring Configurations:
FM1D50 and FM1D50E: ¼" quick connect terminals
FM1D50A: Screw terminals for #10 to #24 AWG wire
Operation Temperature: -13ºF to 131ºF
(-25ºC to 55ºC) (Limited display function at -13ºF)
Warranty: 1 year

C.
www.intermatic.com

23

Electronic Time Switches

Perfect for controlling lighting, ventilation,
heating, cooling, or other electrical loads in
commercial and industrial applications.

FM1D20 Series

One-Circuit Electronic Time Switches

A.

E10694

• 20 setpoint programs
• 3 preset adjustable block programs
• Daylight Saving Time adjustment
• 24-Hour or 7-Day applications
• Simple-to-use programming
• Manual override with load status indication
• Battery backup with 7-year carryover
A. Panel Mounting
Model #

Input Voltage

Clear Dust Cover

FM1D20-120U

120 VAC, 50/60 Hz

No

FM1D20-24U

24 VAC/VDC, 50/60 Hz

No

FM1D20-240U

240 VAC, 50/60 Hz

No

B. Flush Mounting
Model #

Input Voltage

Clear Dust Cover

FM1D20E-120

120 VAC, 50/60 Hz

Yes

FM1D20E-24

24 VAC/VDC, 50/60 Hz

Yes

FM1D20E-240

240 VAC, 50/60 Hz

Yes

C. Surface / DIN Rail Mounting

B.

Model #

Input Voltage

Clear Dust Cover

FM1D20A-120

120 VAC, 50/60 Hz

Yes

FM1D20A-24

24 VAC/VDC, 50/60 Hz

Yes

FM1D20A-240

240 VAC, 50/60 Hz

Yes

Ratings:

C.
24

Power Consumption: 4 VA
Switch Type: SPDT Relay
N.O. Contact:			
½ HP, 120 VAC
1 HP, 240 VAC
16 A, 277 VAC Resistive
12 A, Ballast 120 VAC
8 A, Ballast 240 VAC
720 VA, 240 VAC Pilot Duty
360 VA, 120 VAC Pilot Duty
600 W, Tungsten 120 VAC
1000 W, Tungsten 240 VAC
N.C. Contact: 			
16A, 277 VAC Resistive
8A, 24 VDC
360 VA, 120 VAC Pilot Duty
Dimensions: 
FM1D20A: 2.83" W x 4" H (72 mm x 102.5 mm)
FM1D20E: 2.83" W x 2.83" H (72 mm x 72 mm)
FM1D20: 2.36" W x 2.36" H (60 mm x 60 mm)
Wiring Connections:
"A" Models: Screw terminals for #10 to #24 AWG Wire
"E" Models: ¼" Quick connect terminals
Warranty: 1 year

Electronic Time Switches

EH10 and EH40

Electronic Water Heater Time Switches
•
•
•
•
•
•

42 ON/OFF events per week
7-day scheduling
To-the-minute programming and time-keeping accuracy
External override switch
LED load indicator
Replaceable battery backup
Model #

Input Voltage Switch Watts Enclosure

EH10

120 VAC

SPST

3600

Type 1 Indoor Steel

D. EH40

240 VAC

DPST

7200

Type 1 Indoor Steel

Ratings:
Switch Rating for EH10:
30 A Inductive, 120 VAC 60Hz
30 A Resistive, 120 VAC 60Hz
5 A Tungsten, 120 VAC, 1 HP, 120 VAC
Switch Rating for EH40:
30 A Inductive, 240 VAC 60Hz
30 A Resistive, 240 VAC 60Hz
5 A Tungsten, 240 VAC, 1 ½ HP, 240 VAC

D.

CT2000

Percentage Cycle Time Switch
• Provides 8 field selectable timer durations of 30 seconds,
1, 3, 5, 10, 30 minutes and 1 or 4 hours
• Front cover buttons enable true flexibility for
repetitive cycle times
•	Temporary and permanent manual overrides
• 30 separate positions enable precise percentage
ON time selection
• User settings stored in non-volatile memory
• No DIP switches to program cycle time
• Functions in dusty, ammonia, and wash-down environments
• Withstands surges of up to 6,000 VAC
• Type 3R Indoor/Outdoor Aluminum Enclosure
Model #
E. CT2000

Input Voltage

Switch

120 or 240 VAC, 60 Hz

SPST

Ratings:

Resistive: 20 A,120/240 VAC, 28 VDC
Motor: 1 HP, 120 VAC, 2 HP, 240 VAC
General Purpose: 20 A, 240 VAC
Tungsten (Incandescent): 5 A, 240 VAC
Pilot Duty: 470 VA, 240 VAC
Ballast (Fluorescent): 10 A, 277 VAC
Surge Protection: up to 6,000 VAC
Warranty: Limited 1 year

E.
www.intermatic.com

25

Invest in peace of mind

For more information on the AG3000, see page 97

Landscape lighting control

Electromechanical Time Switches

Electromechanical
Time Switches

Agricultural facilities

Ventilation Lighting Access controls M otors
H ydrop o n i c s y s te m s Waste water Management
Manufacturing facilities Hot Water Heaters
Pumps Security Pump control Animal feeders
Environmental chamber Pool and Spa control
Food equipment General purpose electrical circuits
www.intermatic.com

27

Electromechanical Time Switches
WHAVQ Series

Auto Volt 24-Hour/7-Day
Water Heater Time Switches

E10694

• Heavy-duty 40 Amp contact rating
• Controls commercial, industrial, or residential electric water
heaters up to 10,000 Watts capacity running at 250 VAC
• Type 3R Outdoor Enclosure
• Manual override switch (ON/Auto/OFF)
•	Battery backup with 7-Day carryover
• Power and status LED indicators
• Automatically adjusts voltages between 120 and 277 VAC
• 96 captive trippers 48 ON/OFF
• Easy-to-set true clockface
Model #

Programming

Switch Type

Timing Interval

WHAVQ4

24-Hour

DPDT

15 min.

WHAVQ7

7-Day

DPDT

2 hr.

Ratings:

Input Voltage: 120-277 VAC, 50/60 Hz
Switch Rating:
N.O. Contacts: 40 A Resistive, 250 VAC
10,000 W
N.C. Contacts: 30 A Resistive, 250 VAC
7,500 W
Wiring Connections:
Screw box lug terminals

Environmental Ratings:
Operating Temperature: -4°F to 104°F
(-20°C to 40°C)
Operating Humidity: 0 to 95% RH,
non-condensing
Electrical Life:
50,000 operations at full load
Patent Pending
Warranty: 1 year

For enclosure dimensions, see page 151

28

GM40AV

No Battery Backup
Model #

Programming

Switch Type

Minimum On/Off Time

GM40AV

24-Hour

DPDT

15 min.

GM40AV-W

7-Day

DPDT

2 hr.

GM40AV-M*

24-Hour

DPDT

15 min.

Battery Backup (7-Day Carryover)
Model #

Programming

Switch Type

Minimum On/Off Time

GM40AV-Q

24-Hour

DPDT

15 min.

GM40AV-QW

7-Day

DPDT

2 hrs.

* Mechanism only

Ratings:

N.O. Contacts:
40 A Resistive, 120-277 VAC
1 HP (16 FLA, 90 LRA), 120 VAC
2 HP (12 FLA, 52 LRA), 208-277 VAC
30 A Ballast, 120 VAC
20 A Ballast, 277 VAC
15 A Tungsten, 120 VAC
300 VA Pilot Duty, 120-240 VAC

Electromechanical Time Switches

100 Mechanical Timers All-In-One

N.C. Contacts:
30 A Resistive, 120-277 VAC
1 HP (12 FLA, 30 LRA), 120 VAC
2 HP (10 FLA, 30 LRA), 240 VAC
2 A Tungsten, 120 VAC
10 A Ballast, 277 VAC
Operating Temperature Range:
-40°F to 131°F (-40°C to 55°C)
Battery Backup Models: -4ºF to 131ºF

40 Amp Auto-Voltage
Time Switch

E10694

•9
 6 captive trippers enable 48 ON/OFF
operations each day
• Automatically adjusts voltages between
120 and 277 VAC
• Type 3R Outdoor Enclosure
• Manual override switch (ON/Auto/OFF)
• Easy-to-set true clockface
• Power and status LED indicators
• Mechanism simply snaps into many enclosures

Operating Humidity: 0 to 95% non-condensing
Wire Connections: Screw box lug terminals up to
one #8 AWG wire
Electrical Life: 50,000 operations at full load
Patent Pending
Warranty: 1 year

For enclosure dimensions, see page 151

www.intermatic.com

29

cut through the

darkness

Whirlpools

For more information on LightMaster, see pages 62-67

Agricultural
Signs
HVACR

Billboards

Indoor / O ut door L i ghti ng
Ventilation

Heaters
Fans

Mechanical Time Switches

Mechanical
Time Switches

Landscape Lighting

Oil Well Pumps

Control Panels
www.intermatic.com

Fountains
Pools

Water Heaters
31

Mechanical Time Switches
A.

B.

C.

D.

E.

T100 Series

24-Hour Time Switches
• Direct 24-Hour control of most loads
• Up to 12 ON/OFF operations each day with minimum ON/OFF times of one hour
• Manual override
• One ON and one OFF tripper included
A. Mechanism Only

C. Steel Indoor/Outdoor Enclosure

Model #

Switch

Input Voltage

HP Rating

Model #

Switch

Input Voltage

HP Rating

T101M

SPST

125 VAC, 60Hz

2

T101R

SPST

125 VAC, 60Hz

2

208-277 VAC, 60Hz

5

125 VAC, 60Hz

2

T103M

DPST

125 VAC, 60Hz

2

T102R

SPST

T104M

DPST

208-277 VAC, 60Hz

5

T103R

DPST

T106M **

1NO/1NC

208-277 VAC,60Hz

5

T104R

DPST

208-277 VAC, 60Hz

5

T106R**

1NO/1NC

208-277 VAC, 60Hz

5

B. Steel Indoor Enclosure

D. Plastic Indoor/Outdoor Enclosure

Model #

Switch

Input Voltage

HP Rating

T101

SPST

125 VAC, 60Hz

2

Model #

Switch

Input Voltage

HP Rating

SPST

125 VAC, 60Hz

2

T102

SPST

208-277 VAC, 60Hz

5

T101P

T103

DPST

125 VAC, 60Hz

2

T102P

SPST

208-277 VAC, 60Hz

5

DPST

125 VAC, 60Hz

2

DPST

208-277 VAC, 60Hz

5

T104

DPST

208-277 VAC, 60Hz

5

T103P

T104-50

DPST

208-277 VAC, 50Hz

5

T104P

T101B*

SPST

125 VAC, 60Hz

2

T105 **

1NO/1NC

125 VAC, 60Hz

2

*Separate clock motor terminals for switching circuits not on line voltage.
**Can be wired as SPDT

Ratings:

E. See-Through Indoor/Outdoor Enclosure
Model #

Switch

Input Voltage

HP Rating

T101PCD82

SPST

125 VAC, 60Hz

2

T103PCD82

DPST

125 VAC, 60Hz

2

T104PCD82

DPST

208-277 VAC, 60Hz

5

Switch Ratings: 40 A Resitive each pole, 120-480 VAC, 40 A Inductive Tungsten, 120, 240 or 277 VAC, 1000 VA Pilot
Duty each pole, 120-277 VAC, 2 HP, (24 FLA), 120 VAC, 5 HP, (28 FLA), 240 VAC

Power Consumption: 3 W max.
Operating Temperature: -40ºF to 130ºF (-40ºC to 54ºC)
Warranty: 1 year

For optional enclosure, see page 146; For additional trippers, see page 153; For replacement motors, see page 153

32

Indoor Enclosure

F.

Model #

Switch

Input Voltage

T171

SPST

125 VAC, 60Hz

T172

SPST

208-277 VAC, 60Hz

T173

DPST

125 VAC, 60Hz

T174

DPST

208-277 VAC, 60Hz

T175**

1NO/1NC

125 VAC, 60Hz

T176**

1NO/1NC

208-277 VAC, 60Hz

Model #

Switch

Input Voltage

T173R

DPST

125 VAC, 60Hz

T174R

DPST

208-277 VAC, 60Hz

T1471BR*

4PST

125 VAC, 60Hz

T1472BR*

4PST

208-277 VAC, 60Hz

T1475BR*

4PST

480 VAC, 60Hz

T1871BR* †

2NO/2NC

125 VAC, 60Hz

Outdoor Enclosure

G.

H.

T171CR

SPST

125 VAC, 60Hz

T173CR

DPST

125 VAC, 60Hz

T174CR

DPST

208-277 VAC, 60Hz

T1471BCR*

4PST

125 VAC, 60Hz

H.

Mechanical Time Switches

G.

F.

T170, T1400 and T1800 Series
24-Hour Time Switches with Skipper
and Carryover

• For commercial, industrial and residential applications
• Controls loads up to 40 Amps per pole
• Direct 24-Hour control of most loads
• Up to 10 ON/OFF operations each day
• Minimum ON/OFF times of one hour
• Manual override
•O
 ne ON and one OFF tripper and three day-skipper screws
Models with Carryover (T171CR, T173CR, T174CR, T1471BCR)
•	Minimum of 16 hours carryover operation
•	Carryover automatically rewinds for one hour after power resumes
•	4PST models are ideal for 3-phase load control
Ratings:

Switch Ratings: 40 A Resistive each pole, 120-480 VAC, 40 A Inductive, Tungsten, 120, 240 or 277 VAC,
1000 VA Pilot Duty each pole, 120-277 VAC, 2 HP, (24 FLA), 120 VAC, 5 HP, (28 FLA), 240 VAC
4PST models also 7.5 HP (28 FLA) 208 VAC, 10 HP (28 FLA) 240 VAC 3-phase
Power Consumption: 3 W max.
Operating Temperature: -40ºF to 130ºF (-40ºC to 54ºC)
Warranty: 1 year

*Separate clock motor terminals for switching
circuits not on line voltage
**Can be wired as SPDT
† Can be wired as DPDT

For additional trippers, see page 153; For additional skipper screws, see page 152; For replacement motors, see page 153

www.intermatic.com

33

Mechanical Time Switches
A.

C.

B.

T1900 Series and T1970 Series
24-Hour Time Switches with Skipper
• Provides up to 96 operations (48 ON/48 OFF) every 24 hours
• Skipper models provide 80 operations daily and can be
omitted on selected day(s) of the week
• 15-minute intervals
• Trippers slide in and out of dial for fast, accurate setting
Ratings:

Switch Ratings: 20 A, 125, 208-277 and 480 VAC, ½ HP, 120 VAC, 1 HP 240 VAC
Power Input: 3 W Max.
Operating Temperature: -40°F to 130°F (-40°C to 54°C)
Warranty: 1 year

Indoor Enclosure
Model # Switch

Input Voltage

Skipper Wheel

SPDT

125 VAC, 60 Hz

No

T1905E*

SPDT

480 VAC, 60 Hz

No

T1906*

SPDT

208-277 VAC, 60 Hz

No

T1975†

SPDT

125 VAC, 60 Hz

Yes

T1976†

SPDT

208-277 VAC, 60 Hz

Yes

T1975E†

SPDT

480 VAC, 60 Hz

Yes

A. T1905*

Steel Indoor/Outdoor Enclosure
Model # Switch
B. T1975R†

SPDT

T1976R†

SPDT

T1975ER† SPDT

Input Voltage

Skipper Wheel

125 VAC, 60 Hz

Yes

208-277 VAC, 60 Hz

Yes

480 VAC, 60 Hz

Yes

Plastic Indoor/Outdoor Enclosure
Model # Switch
C. T1905P*

SPDT

Input Voltage

Skipper Wheel

125 VAC, 60 Hz

No

*Replacement Snap Switch 133T701A
†Replacement Snap Switch 133T698A
For additional trippers (156T1950A), see page 153;
For replacement motors, see page 153

34

NEW

NEW

D.

Mechanical Time Switches

Industrial Grade
To u g h n e s s

E.

T1905HD and T1975EHD
Heavy-Duty Time Switch

•H
 eavy-duty metal dial withstands the most
punishing environmental conditions
• Easy-to-set trippers slide in/out for fast, accurate setting
• Up to 96 operations (48 ON/48 OFF) every 24 hours
• 15-minute intervals
• Indoor enclosure
Model #

Switch

Input Voltage

Skipper Wheel

Motor

D. T1905HD

SPDT

120 VAC 60 Hz

No

120 VAC motor with protected gears

E. T1975EHD

SPDT

480 VAC 60 Hz

Yes

480 VAC, encapsulated motor

Ratings:

Switch Ratings: 20 A Max., 120, 208-277 and 480 VAC, ½ HP, 120 VAC, 1 HP 240 VAC
Power Input: 3 W Max.
Operating Temperature: -40°F to 130°F (-40°C to 54°C)
Warranty: 1 year
For maximum performance, Intermatic recommends adding a
5 to 8 minute offset to your ON/OFF events.

www.intermatic.com

35

Mechanical Time Switches
A.

B.

T50000 Series

7-Day Timing Control Centers with Carryover
• Includes photo control initiated/time switch terminated control
• Enable different ON/OFF programs each day of the week
• Recommended for applications needing to turn a load ON at dusk and OFF
at a preset time
• Minimum of 16 hours carryover for maintaining preset schedules during
power failures
• Only one hour of rewinding time required for every two hours of power outage
• Carryover automatically rewinds when power resumes
• Light level adjustment
• Single pole double throw switches and manual circuit bypass switches
• Controls the contactor coil circuit only
Model #

Circuits

Voltage

A. T51211BC

2

120 VAC, 60 Hz

B. T51311BC

3

120 VAC, 60 Hz

Note: All models have separate clock motor terminals for switching circuits not on line voltage.
They may be used with 24 volt systems if wired in accordance with NEC regulations.
Not recommended for direct switching of tungsten, mercury vapor, or similar loads.

Rating:

Enclosure: Type 1 rated indoor steel 12 ½" H x 8 ¼" W x 3 7⁄8" D
Contact Ratings: 15 A, ½ HP, 125-250 VAC, 420 VA Pilot Duty, 150 W Tungsten, 125 VAC
Operating Temperature Range: -40°F to 130°F (-40°C to 54°C)
Warranty: 1 year
For additional trippers (156T2548A), see page 153

36

Includes
K4121C Photo Control

7-Day Time Switches
With Optional Carryover
• Different ON/OFF programs each day of the week
• True 7-day load control with minimum ON/OFF time of 3 1 ⁄2 hours
• Separate clock motor terminals for switching loads
not on-line voltage
• Carryover automatically rewinds when power resumes
• Minimum of 16 hours carryover for maintaining preset schedules
during power failures
Type 1 Steel Indoor Enclosure Without Carryover
Model #

Switch

Input Voltage

C. T7401B

4PST N.O.

120 VAC, 60 Hz

T7402B

4PST N.O.

208-277 VAC, 60 Hz

T7801B*

2 N.O./ 2 N.C.

120 VAC, 60 Hz

T7802B*

2 N.O./ 2 N.C.

208-277 VAC, 60 Hz

C.

Type 3R Steel Outdoor Enclosure With Carryover
Model #
D. T7401BCR

Switch

Input Voltage

4PST N.O.

120 VAC, 60 Hz

Type 1 Steel Indoor Enclosure With Carryover
Model #

Switch

Input Voltage

T7401BC

4PST N.O.

120 VAC, 60 Hz

T7402BC

4PST N.O.

208-277 VAC, 60 Hz

T7801BC*

2 N.O./ 2 N.C.

120 VAC, 60 Hz

Mechanical Time Switches

T7000B Series

*Can be wired as (2) DPDT
Note: All models have separate clock motor terminals for switching
circuits not on-line voltage. They may be used with 24 volt systems if
wired in accordance with NEC regulations.

Rating:

Enclosure: Type 3R rated outdoor steel enclosure
Type 1 rated indoor steel in gray finish with separate grounding terminal.
12 ½" (31.7 cm) H x 8 ¼" (21.0 cm) W x 4" (10.2 cm) D
Knockouts: Combination ½" – ¾" nominal knockouts, two on back, one on each side and two
on bottom. Also one 1" nominal on bottom center.
Switch Rating: Each Pole 40 A Resistive, 120-480 VAC, 40 A Tungsten, 120-277 VAC 1000 VA
Pilot Duty, 120-277 VAC, 2 HP (24 FLA) 120 VAC, 5 HP (28 FLA) 240 VAC single phase;
7 ½ HP (28 FLA) 208 VAC 3 phase, 10 HP (28 FLA) 240 VAC 3 phase.
Operating Temperature Range: -40°F to 130°F (-40°C to 54°C)
Warranty: 1 year

D.

For additional trippers (156T2548A), see page 153;
For replacement motors, see page 153

T2000 Series

Compact 7-Day Time Switches
• Minimum 2-hour timing intervals
• Up to 42 ON/OFF operations per week
• Type 1 indoor steel enclosure
Model #

Switch

Input Voltage

HP

E. T2005

SPDT

120 VAC, 60 Hz

½

T2006

SPDT

208, 277 VAC, 60 Hz

1

Rating:

Switch Rating: 20 A Resistive, 125 and 208-277 VAC
Operating Temperature Range: -40°F to 130°F (-40°C to 54°C)
Warranty: 1 year
For additional trippers (156T1950A), see page 153;
For replacement motors, see page 153;
For replacement snap switch 133T701A, see page 153

E.
www.intermatic.com

37

Mechanical Time Switches

B.

A.

C8800 Series

Short Range Cycle Time Switches
• Repeat cycling for ON times
• 10 trippers provided
• Dials have 120 slots
• Type 1 indoor steel enclosure
Model #

Clock Motor Voltage

Dial Cycle

Tripper Actuating Time

Switch

C8815

125 VAC, 60 Hz

10 Min.

5 Sec.

SPDT

A. C8835

125 VAC, 60 Hz

30 Min.

15 Sec.

SPDT

C8845

125 VAC, 60 Hz

4 Hr.

120 Sec.

SPDT

B. C8865

125 VAC, 60 Hz

1 Hr.

30 Sec.

SPDT

208-277 VAC, 60 Hz

1 Hr.

30 Sec.

SPDT

C8866

Note: The life of the switch contacts is affected by the size and type of the controlled load.
The expected minimum life at 20 Amps (resistive) load is 100,000 cycles.

Ratings:

Switch Rating: 20 A Resistive, 120-480 VAC, ½ HP,
120 VAC, 1 HP, 240 VAC
Operating Temperature: -40°F to 130°F (-40°C to 54°C)
Warranty: 1 year
For additional trippers (156T1950A), see page 153
For replacement switch (133T773A), see page 153
For enclosure dimensions, see page 146

38

Mechanical Time Switches

C.

D.

R8800 and T8800 Series

Sprinkler/Irrigation Time Switches with 14-Day Skipper
• Up to 44 ON/OFF settings per day
• Water metering increments from 12 minutes to 20 hours and 45 minutes
• 14-Day Skipper enables irrigation to be omitted on selected day(s)
• Provides for “every other” day operation
• ON/OFF/AUTOMATIC switch enables shutdown during rainy days and extended
watering during dry periods without disturbing the cycle set on dial
Mechanism Only
Model #

Switch

Clock Motor Voltage

Load Voltage

Amps (per pole)

HP

T8805M101C

SPST

120 VAC, 60 Hz

120 VAC, 60 Hz

15

½

C. R8806M101C

DPST

240 VAC, 60 Hz

240 VAC, 60 Hz

25

2

Plastic Type 3R Enclosure
Model #

Switch

Clock Motor Voltage

Load Voltage

Amps (per pole)

HP

D. T8805P101C

SPST

120 VAC, 60 Hz

120 VAC, 60 Hz

15

½

R8806P101C

DPST

240 VAC, 60 Hz

240 VAC, 60 Hz

25

2

R8815P101C* DPST

120 VAC, 60 Hz

120 VAC, 60 Hz

25

1½

R8816P101C* DPST

240 VAC, 60 Hz

240 VAC, 60 Hz

30

3

T8845PV**

120 VAC, 60 Hz

24 VAC, 60 Hz

20 VA

-

SPST

*Rain sensor enabled (rain sensor not included)
**Includes 24 Volt, 20VA transformer

Ratings:

Operating Temperature: -40°F to 130°F (-40°C to 54°C)
Warranty: 1 year
For additional trippers (156T1950A), see page 153
For replacement switch (133T700A), see page 153
For additional skipper pins (156T1954A), see page 153
For enclosure dimensions, see page 146

www.intermatic.com

39

Mechanical Time Switches

Talento 121

One-Hour Repeat Cycle
Mechanical Time Switch
• Synchronous motor
• Low cost repeat cycle timer for industrial processes
and other applications
• Continuous ON/OFF load cycling in a one-hour repeating pattern
• Captive trippers enable up to 24 ON and 24 OFF times in 1.25
minute increments over a one-hour period
• Can be used with an Intermatic 24-Hour or 7-Day time switch to
provide repeat cycle switching during selected periods
• Surface or DIN Rail mounted with panels or mounted in an
Intermatic indoor or outdoor enclosure
• Available with 3-way override
A.

A.

Model #

Input Voltage

Total Cycle Time Timing Interval

Switch Output

TALENTO121-120

120 VAC

1 Hr.

1.25 Min.

SPDT, 16 Amp

TALENTO121-240

208-240 VAC

1 Hr.

1.25 Min.

SPDT, 16 Amp

GMX121-O-120*

120 VAC

1 Hr.

1.25 Min.

SPDT, 16 Amp

* Mounted in Type 3R enclosure

Ratings:

Dimensions:
3.31" (8.41 cm) H x 2.13" (5.41 cm) W x 2.56" (6.5 cm) D
Minimum Switching Time: 1.25 minutes
Switch Output: SPDT isolated contacts
16 A Resistive, 125-250 VAC
750 W Tungsten, 250 VAC
Operating Temperature: 32°F to 131°F (0°C to 55°C)
Operating Humidity: 0 to 95% RH non-condensing
Wiring Connections: Screw terminals for up to #12 AWG wire

FM1S12HU-120U
12-Hour Repeat Cycle
Time Switch

40

E10694

• 21 Amp STDT switch
• Panel mount
• Captive trippers enable up to 48 ON and
48 OFF times in 7.5 minute intervals

B.

B.

LR3730

Model #

Input Voltage

Total Cycle Time

Timing Interval

FM1S12HU-120U

120 VAC

12 Hr.

7.5 Min.

Ratings:

Dimensions: 2.36" H x 2.36" W (60 mm H x 60 mm W)
Supply Voltage: 120 VAC
Power Consumption: 1 VA
Switch Rating: SPDT
Resistive: 21 A, 250 VAC
Inductive: 1 HP, 125 VAC, 2 HP, 240 VAC
Wiring Connections: 1⁄4" quick-connects

Mechanical Time Switches

V45000 Series

Astronomic Dial Time Switches
with Skipper
•
•
•
•
•

Adjusts for seasonal changes
3PST switch configuration
Three Skipper screws furnished
Independent clock motor terminals
 nly one hour required to rewind the carryover
O
for every two hours of outage
30° Latitude
Model #

Carryover

VAC 60 Hz

V45472CR30

Yes

120

V45472CR30

Yes

208-277

V45471R30

No

120

V45472R30

No

208-277

Model #

Carryover

VAC 60 Hz

V45471CR34

Yes

120

V45472CR34

Yes

208-277

V45471R34

No

120

V45472R34

No

208-277

34° Latitude

C.

42° Latitude

C.

Model #

Carryover

VAC 60 Hz

V45471CR42

Yes

120

V45472CR42

Yes

208-277

V45471R42

No

120

V45472R42

No

208-277

42

Ratings:

34

Enclosure: Type 3R rated steel, gray finish with hasp, with hole for lock, holds permanently
attached, side hinged door closed. Mounting bracket plus two holes below switch on back for
mounting. Separate grounding terminal. 81⁄4" (20.95 cm) H x 51⁄4" (13.34 cm) W x 43⁄4" (12.07 cm) D
Knockouts: Combination 1⁄2" – 3⁄4" nominal knockouts, one on back and each side of enclosure and
two on bottom.
Switch Rating: Each pole 40 A Resistive 120-277 VAC, 40 A Tungsten 120 VAC, 690 VA Pilot Duty
120-277 VAC, 1 HP, 120-277 VAC, 5 HP, 240 VAC
Operating Temperature: 32°F to 104°F (0ºC to 40ºC)
Warranty: 1 year

30
Ordering Guidelines: See map to find your latitude zone.
Add the zone to the end of the model number. For example: If you
are in Zone 42 (Red), the order number is V45471CR42.

T104-20, WH21 and WH40

Mechanical Water Heater Time Switches
• Three sets of ON/OFF trippers
• Enables shifting electricity use into off-peak hours to reduce energy costs
• Convenient external override switch (WH40 and WH21 models)
Clock Motor
VAC

Cycle

Amps
Watts
External
per pole Resistive Override

DPST

208-240

60

40

10000

No

WH21

SPST

208-240

60

25

6250

Yes

D. WH40

DPST

208-240

60

40

10000

Yes

Model #

Switch Type

T104-20

Ratings:

Enclosure: Type 1 Indoor Steel
Power Consumption: 3 W max.

Operating Temperature Range: -40°F to°130°F (-40°C to 54°C)
Warranty: 1 year

D.
www.intermatic.com

41

Mechanical Time Switches

A.

B.

C.

D.

FM1 Series

Panel Mount Timer Modules

E10694

LR3730

• 21 Amp SPDT Switch
• Captive Trippers
• ¼" quick-connect terminals
• Noise resistant - ideal for robust applications
• Available with synchronous drive or quartz drive with battery backup (7-Day carryover)
• Easy-to-set true clock face
• Available with manual override (ON/Auto/OFF)
• Compact size fits in small areas
A.

24-Hour (15-Minute ON/OFF Time) with Override

C.

7-Day (2-Hour ON/OFF Time) with Override

Model #

Input Voltage

Battery Backup

Model #

Input Voltage

Battery Backup

FM1QTUZH-120U

120

Yes

FM1QWUZH-120U

120

Yes
Yes

FM1QTUZH-24U*

12, 24

Yes

FM1QWUZH-240U

208/240

FM1STUZH-120U

120

No

FM1QWUZH-BW-24U*

12, 24

Yes

FM1STUZH220/50

220 (50 Hz)

No

FM1SWUZH-120U

120

No

208/240

No

24

No

FM1STUZH-240U

208/240

No

FM1SWUZH-240U

FM1STUZH-24U

24

No

FM1SWUZH-24U

B.

24-Hour (15-Minute ON/OFF Time) without Override

D.

7-Day (2-Hour ON/OFF Time) without Override

Model #

Input Voltage

Battery Backup

Model #

Input Voltage

Battery Backup

FM1QTUZ-120U

120

Yes

FM1QWUZ-120U

120

Yes

FM1QTUZ-240U

208/240

Yes

FM1QWUZ-240U

208/240

Yes

FM1QTUZ-24U*

12, 24

Yes

FM1SWUZ-120U

120

No

FM1STUZ-120U

120

No

FM1SWUZ-240U

208/240

No

No

FM1SWUZ-24U

24

No

FM1STUZ-240U

208/240

FM1STUZ220/50

220 (50 Hz)

No

FM1STUZ-24U

24

No

Note: Clear plastic cover available (DC-FME-A)
Note: FM1 models with Q suffix are quartz models. FM1 models with S suffix are
synchronous models.
*Quartz 24= 12-24 VDC/VAC

Ratings

Dimensions: 2.36" H x 2.36" W (60 mm H x 60 mm W)
Input Voltage: S ynchronous: 24, 120, 208/240 VAC, 60 Hz; 220 Hz, 50Hz
Quartz: 12, 24 VAC/DC, 120, 208/240 VAC 50/60 Hz
Power Consumption: 1 VA

42

Wire Conections: 1⁄4" Quick connect
Switch Rating: 21 A Resistive, 120-250 VAC, 1 HP, 120 VAC, 2 HP, 250 VAC, 1350 W Tungsten, 240 VAC
Operating Temperature: Synchronous: -40°F to 185°F (-40°C to 85°C)
Quartz: -4°F to 131°F (-20°C to 55°C)

Mechanical Time Switches

GMX Series

24-Hour/7-Day General
Purpose Time Switch

E10694

• Manual override (ON/Auto/OFF)
• 21 Amp SPDT Switch
• Captive trippers
• Easy-to-set true clock face
• Finger-safe terminals
• Extra space in enclosure for field-added contractor or accessories
• Available with synchronous drive or quartz drive with battery backup
24-Hour (15-Minute ON/OFF time)
Model #

Input Voltage Enclosure

7-Day (2-Hour ON/OFF time)
Battery Backup

Model #

Input Voltage Enclosure

Battery Backup

GMXQT-I-120

120

Type 1 Indoor

Yes

GMXQW-I-120

120

Type 1 Indoor

Yes

GMXQT-I-24*

24

Type 1 Indoor

Yes

GMXQW-I-24*

24

Type 1 Indoor

Yes

GMXQT-O-120

120

Type 3R Outdoor

Yes

GMXQW-I-240

208/240

Type 1 Indoor

Yes

GMXST-I-120

120

Type 1 Indoor

No

GMXQW-O-120 120

Type 3R Outdoor

Yes

GMXST-I-24

24

Type 1 Indoor

No

GMXSW-I-120

120

Type 1 Indoor

No

GMXST-I-240

208/240

Type 1 Indoor

No

GMXSW-I-24

24

Type 1 Indoor

No

GMXST-O-120

120

Type 3R Outdoor

No

GMXSW-I-240

208/240

Type 1 Indoor

No

GMXST-O-24

24

Type 3R Outdoor

No

GMXSW-O-120 120

Type 3R Outdoor

No

GMXST-O-240

208/240

Type 3R Outdoor

No

GMXSW-O-24

*Quartz 24 = 12-24 VDC/VAC

24

GMXSW-O-240 208/240

Type 3R Outdoor

No

Type 3R Outdoor

No

Note: FM1 models with Q suffix are quartz models. FM1 models with S suffix
are synchronous models.

Ratings:

Switch Rating: 21A Resistive, 120-250 VAC, 1 HP, 120 VAC, 2 HP, 240 VAC, 1,350W Tungsten, 240 VAC
Wiring Connections: Screw terminal accepts up to #12 AWG wire
Operating Temperature: Synchronous: -40˚F to 185˚F (-40˚C to 85˚C)
Quartz: -4˚F to 131˚F (-20˚C to 55˚C)
Operating Humidity: 0 to 95% non-condensing
Enclosure Dimensions: 10" H x 6.5" W x 3.75" D (25.4 cm H x 16.51 cm W x 9.53 cm D)
Battery Backup Option: 7-Day carrryover (Quartz models only)
Input Voltage: S ynchronous: 24, 120, 208/240 VAC, 60 Hz
Quartz: 12, 24 VDC/VAC 120, 208/240 VAC 50/60 Hz

www.intermatic.com

43

Mechanical Time Switches

B.

A.

MIL72 Series 24 Hour

Surface/DIN Rail or Flush Mount Timer Modules

E10694

LR3730

• Designed for use in a control panel
• 15-minute minimum ON/OFF times
• 21 Amp SPDT switch
•C
 aptive trippers
• Available with synchronous drive or quartz drive with battery backup
• Easy-to-set true clock face
• Available with or without manual override (ON/Auto/OFF)
• Clear plastic dust cover
A. Surface/DIN Rail Mount

B. Flush Mount

Model #

Input Voltage Override Battery Backup

Model #

Input Voltage Override Battery Backup

MIL72AQTUZ-120

120

No

Yes

MIL72EQTUZ-120

120

No

Yes

MIL72AQTUZ-240

208/240

No

Yes

MIL72EQTUZ-24*

24

No

Yes

MIL72AQTUZH-120

120

Yes

Yes

MIL72EQTUZ-240

208/240

No

Yes

MIL72AQTUZH-24*

24

Yes

Yes

MIL72EQTUZH-120

120

Yes

Yes

MIL72ASTUZ-120

120

No

No

MIL72EQTUZH-24*

24

Yes

Yes

No

No

MIL72ASTUZ-24

24

No

No

MIL72ESTUZ-120

120

MIL72ASTUZ-240

208/240

No

No

MIL72ESTUZ-24

24

No

No

MIL72ASTUZH-120

120

Yes

No

MIL72ESTUZ-240

208/240

No

No

MIL72ASTUZH-24

24

Yes

No

MIL72ESTUZ1A240

208/240

No

No

MIL72ASTUZ-240

208/240

Yes

No

MIL72ESTUZH-120

120

Yes

No

MIL72ASTUZ220

220

Yes

No

MIL72ESTUZH-24

24

Yes

No

MIL72ESTUZH-240

208/240

Yes

No

MIL72ESTUZH220

220

Yes

No

*Quartz 24 = 12-24VDC/VAC
Note: FM1 models with Q suffix are quartz models. FM1 models with S
suffix are synchronous models.

Ratings:

Switch Rating: 21 A Resistive, 120-250 VAC, 1 HP, 125 VAC, 2 HP, 250 VAC, 1350 W Tungsten, 120 VAC
Wiring Connections: Screw terminal connections (MIL72A) 1⁄4" quick connects (MIL72E) accepts up to #12 GA wire
Operating Temperature: -40ºF to 185ºF (-40ºC to 85ºC) with battery backup -4ºF to 131ºF (-20ºC to 55ºC)
Operating Humidity: 0 to 95% non-condensing
Battery Backup Option: 7-Day carryover (Quartz models only)

44

Input Voltage: Synchronous models: 24, 120, and 208/240 VAC, 60 Hz ; 220
VAC, 50 Hz Quartz: 24 VAC/DC, 120 and 208/240 VAC 50/60 Hz, 50 Hz
Power Consumption: 24 VAC: 0.1 VA, 120 VAC: 0.5 VA, 240 VAC: 1.0 VA
Installation: Standalone or with Indoor/Outdoor enclosure

MIL72 Series 7 Day

Surface/DIN Rail or Flush Mount Timer Modules

Mechanical Time Switches

D.

C.

E10694

LR3730

• Designed for use in a control panel
• 2-hour minimum ON/OFF times
• Clear plastic dust-cover
• 21 Amp SPDT switch
• Captive trippers
• Available with synchronous drive or quartz drive with battery backup
• Easy-to-set true clock face
• Available with or without manual override (ON/Auto/OFF)
C. Surface/DIN Rail Mount

D. Flush Mount

Model #

Input Voltage Override

Battery Backup

Model #

Input Voltage Override

Battery Backup

MIL72AQWUZ-120

120

No

Yes

MIL72EQWUZ-120

12

No

Yes

MIL72AQWUZH-120

120

Yes

Yes

MIL72EQWUZH-120

120

Yes

Yes

MIL72AQWUZH-24*

24

Yes

Yes

MIL72EQWUZH-24*

24

Yes

Yes

MIL72AQWUZH-240

208/240

Yes

Yes

MIL72EQWUZH-240

208/240

Yes

Yes

MIL72ASWUZ-120

120

No

No

MIL72ESWUZ-120

120

No

No

MIL72ASWUZ-24

24

No

No

MIL72ESWUZ-24

24

No

No

MIL72ASWUZ-240

208/240

No

No

MIL72ESWUZH-120

120

Yes

No

MIL72ASWUZH-120

120

Yes

No

MIL72ESWUZH-24

24

Yes

No

MIL72ASWUZH-24

24

Yes

No

MIL72ESWUZH-240

208/240

Yes

No

MIL72ASWUZH-240

208/240

Yes

No

*Quartz 24= 12-24VDC/VAC
Note: FM1 models with Q suffix are quartz models. FM1 models with S
suffix are synchronous models.

Ratings

Switch Rating: 21 A Resistive, 120-250 VAC 1 HP, 125 VAC, 2 HP, 250 VAC, 1350 W Tungsten, 120 VAC
Wiring Connections: Screw terminal connections (MIL72A) 1⁄4" quick connects (MIL72E) accepts up to #12 GA wire
Operating Temperature: -40ºF to 185ºF (-40ºC to 85ºC) with battery backup -4ºF to 131ºF (-20ºC to 55ºC)
Operating Humidity: 0 to 95% non-condensing
Battery Backup Option: 7-Day carryover (Quartz models only)
Input Voltage: Synchronous: 24, 120, and 208/240 VAC, 60 Hz models
Quartz: 24 VAC/DC, 120 and 208/240 VAC 50/60 Hz
Power Consumption: 24 VAC: 0.1 VA 120 VAC: 0.5 VA, 240 VAC: 1.0 VA
Installation: Standalone or with Indoor/Outdoor enclosure

www.intermatic.com

45

Mechanical Time Switches

A.

B.

F.

Low Voltage
Power Packs
• 120 VAC input, 12 VAC output
• Available from 44 to 900 Watts
• Keyhole mounting for easy
installation and operation
• For outdoor use only

E.

D.

C.

H.

G.

Model #

J.

Description

Max. Wattage Output

Color

A. ML44T

Timer with 2 sets of trippers

44 Lamp Watts

Black

ML88T

Timer with 2 sets of trippers

88 Lamp Watts

Black

B. ML100THB

Electronic timer and photo control

100 Lamp Watts

Black

C. ML121RT

Timer with 2 sets of trippers

121 Lamp Watts

Black

ML200RT

Timer with 2 sets of trippers

200 Lamp Watts

Black

ML200RTW

Timer with 2 sets of trippers and ground shield

200 Lamp Watts

Black

D. ML300RTW

Timer with 2 sets of trippers and ground shield

300 Lamp Watts

Black

E. ML300RTWSN

Timer with 2 sets of trippers and ground shield

300 Lamp Watts

Sand

F. ML600TW

Timer with 2 sets of trippers and ground shield

600 Lamp Watts

Black

G. ML600TWSN

Timer with 2 sets of trippers and ground shield

600 Lamp Watts

Sand

H. ML900TW

Timer with 2 sets of trippers and ground shield

900 Lamp Watts

Black

J. ML900TWSN

Timer with 2 sets of trippers and ground shield

900 Lamp Watts

Sand

Note: When planning your lighting, total bulb wattage must not exceed maximum transformer output.

ML814DRP

Photo Eye Accessory
•A
 utomatically controls low voltage
transformers based on sunrise & sunset
• Used with 100 Watt or greater transformers

46

Model #

Voltage

Watts Tungsten

ML814DRP

12 VAC 50/60 Hz

300

Timers

Timers
Timers
Bathroom Lighting
Hallway Lighting
Holiday Lights
Lamps
E n try Light ing Display Lighting
Saunas Small Appliances
Security Lighting Whirlpools
www.intermatic.com

47

Timers

Set It
And Forget It

A.

B.

C.

EI600 Series

Heavy-Duty Electronic In-Wall Timers
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
48

Versatile 7-Day scheduling
Up to 40 programmable ON/OFF events
No neutral required
Random setting turns lights ON/OFF at different times so it
appears someone is always at their home or business
Auto Daylight Saving Time adjustment
Astronomic feature can be combined with specific timed
ON/OFF programming
Incandescent/Fluorescent/CFL/LED compatible
Can control switched outlets
Controls AC or DC loads
Non-volatile memory stores user programs
Manual override
Replaceable CR2 lithium battery provides up to 3 years of
operation without AC power
Single-pole or 3-way compatible
Able to install in multi-gang installations without derating
For use with decorator-style wall plate (not included)
Isolated Single-Pole Single-Throw switch allows the timer to
switch any load type
Limited 5-year warranty

Model #

Color

A. EI600C

Ivory

B. EI600WC

White

C. EI600LAC

Light Almond

Ratings:

Resistive (heater): 20 A, 120-277 VAC
Tungsten (incandescent): 15 A, 120 VAC; 6 A, 208-277 VAC
Inductive Ballast: 16 A, 120-277 VAC
Motor: 1 HP, 120 VAC, 2 HP, 240 VAC
DC Loads: 4 A, 12 VDC, 2 A, 28 VDC
Max. Wattage: 2400 W, 120 VAC, 5540 W, 277 VAC
Operating Temperature: 32˚F to 104˚F (0˚C to 40˚C)
Not for use with sunlamps, saunas, or loads that could cause personal injury if
timed incorrectly

Timers

D.

Model #

Color

D. EI500C

Ivory

E. EI500WC

White

F. EI500LAC

Light Almond

Ratings:

General Purpose: 15 A
Resistive (heater): 15 A
Tungsten (incandescent): 1000 W
Inductive Ballast: 8 A
Electronic Ballast: 500 VA
Motor: 1⁄4 HP
Input Voltage: 125 VAC 60 Hz.
Max. Wattage: 1875 W
Operating Temperature: 32˚F to 107˚F (0˚C to 40˚C)
Switch: Single Pole Single Throw
Warranty: Limited 1 year
Not for use with sunlamps, saunas, or loads that could cause
personal injury if timed incorrectly

E.

F.

EI500 Series

Electronic In-Wall Timers
• Up to 14 programmable ON/OFF events
• Random setting turns lights ON/OFF at different times so
it appears someone is always at their home or business
• Incandescent/Fluorescent/CFL/LED compatible
• 24-Hour or 7-Day load control of lights, fans, pumps and
other medium-duty loads
• Built-in rechargeable battery backup
• For use with decorator-style wall plate (not included)
•	Easy to program
•	Replaces single-pole switches in many applications
•	Requires neutral wire
•	Continuously displays time of day, mode and load status

Is Your Home Protected?
Add an AG3000 Surge Protective Device to your home
to protect your furnace and air conditioner from power
surges and spikes. For more information about the
AG3000, turn to page 97.

www.intermatic.com

49

Timers
A.
B.

ST01 and ST01A

Heavy-Duty In-Wall Timers
•
•
•
•
•
•
•
•
•
•
•
•
•
•

50

Versatile 7-Day scheduling
Up to 40 ON/OFF programmable events per week
No neutral required
Random setting turns lights ON/OFF at different times so it appears
someone is always at their home or business
Auto Daylight Saving Time adjustment
Astronomic feature can be combined with specific timed ON/OFF programming
Incandescent/Fluorescent/CFL/LED compatible
Can control switched outlets
Controls AC or DC loads
Programs stored in non-volatile memory
Manual override
Single-pole or 3-way compatible
For use with decorator-style wall plate (not included)
Replaceable CR2 lithium battery provides up to 3 years of operation
without AC power

Model #

Color

A. ST01

White

B. ST01A

Almond

Ratings:

Resistive (heater): 15 A, 120-277 VAC
Tungsten (incandescent): 15 A, 120 VAC, 6 A,
208-277 VAC
Ballast (Fluorescent): 8 A, 120 VAC, 4 A, 208-277 VAC
Motor: 1 HP, 120 VAC, 2 HP, 240 VAC
DC Loads: 4 A 12 VDC, 2 A, 28 VDC
Operating Temperature: 32°F to 122°F (0°C to 50°C)
Warranty: Limited 1 year

Not for use with sunlamps, saunas, or loads that could
cause personal injury if timed incorrectly

24-Hour or 7-Day In-Wall Timers
• Up to 14 (7 ON/OFF) programmable events per day
• Random setting turns lights ON/OFF at different times so
it appears someone is always at their home or business
• Auto Daylight Saving Time adjustment
• Incandescent/Fluorescent/CFL/LED compatible
• Astronomic feature auto adjusts to sunrise/sunset
• Can be used for 24-Hour or 7-Day load control of lights,
fans, pumps and other medium-duty loads
• Built-in rechargeable lithium ion battery backup
• Single-pole or 3-way compatible
• For use with decorator-style wall plate (not included)
• Requires neutral wire
Model #
Color
C. EJ600

White

D. EJ600A

Almond

Ratings:

Input Voltage: 120 VAC, 60 Hz.
General Purpose: 12 A, 120 VAC, 60 Hz.
Resistive (heater): 12 A, 120 VAC, 60 Hz.
Tungsten (incandescent):
15 A single-gang, 12 A multi-gang

Inductive Ballast: 500 VA
Motor: 1⁄2 HP
Operating Temperature: 32°F to 104°F
(0°C to 40°C)
Warranty: Limited 1 year

C.
D.

E.

F.

EJ500

EJ351

Electronic In-Wall Switch Timer

Programmable 24-Hour Security Timer
•
•
•
•

Up to 48 ON/OFF programmable events
No neutral required
Self learning, adapts to your schedule to meet your demands
Random setting turns lights ON/OFF at different times so it
appears someone is always at their home or business
• Controls incandescent lighting
• 15-minute memory guard protects against power failure
• For use with standard or decorator-style wall plate
(not included)
Ratings:

Input Voltage: 120 VAC, 60 Hz.
Min. Wattage: 40 W
Max. Wattage: 500 W Incandescent
Inductive Ballast: 4 A
Operating Temperature:
32°F to 104°F (0°C to 40°C)
Warranty: Limited 1 year

Timers

NEW

EJ600 Series

Model #
E. EJ351

Color

• Versatile 7-Day scheduling
• Up to 14 (7 ON/OFF) programmable events per day
• No neutral required
• Random setting turns lights ON/OFF at different times so it
appears someone is always at their home or business
• Auto Daylight Saving Time adjustment
• Astronomic feature auto adjusts to sunrise/sunset
• Controls incandescent lighting
• Battery backup
• Single-pole or 3-way compatible
• For use with decorator-style wall plate (not included)
Ratings:

White

Not for use with CFL/LED bulb

Tungsten: 4 A
Input Voltage: 120 VAC, 60 Hz.
Inductive Ballast: 4 A
Min. Wattage: 40 W
Operating Temperature:
Max. Wattage:
32°F to 104°F (0°C to 40°C)
500 W Incandescent
Warranty: Limited 1 year

www.intermatic.com

Model #
F. EJ500

Color
White

Not for use with
CFL/LED bulbs

51

Timers
A.

B.

C.

EI400 Series

Electronic Auto-Off In-Wall Timers
•
•
•
•
•
•
•
•
•
•
•
•

52

To-the-second accuracy time range from 1 second to 24 hours
Single-pole or 3-way compatible
No neutral required
Replaceable CR2 lithium battery provides up to 3 years of
operation without AC Power
Non-volatile memory stores user programs
ADA Compliant
Audible and/or visual load switch OFF warning
Controls all voltages and frequencies within the correct ratings
with no adjustments required
CFL/LED compatible
For use with decorator-style wall plate (not included)
Low battery indicator
Limited 5-year warranty

Model #

Color

A. EI400C

Ivory

B. EI400WC

White

C. EI400LAC

Light Almond

Ratings:

Input Voltage: 120-277 VAC, 12-28 VDC 50/60 Hz.
Resistive (heater): 20 A, 120-277 VAC
Tungsten (incandescent): 15 A, 120 VAC, 6 A, 208-277 VAC
Inductive Ballast: 16 A, 120-277 VAC
Motor: 1 HP, 120 VAC, 2 HP, 240 VAC
DC Loads: 4 A, 12 VDC, 2 A 28 VDC
Max. Wattage: 2400 W at 120 VAC, 5540 W at 277 VAC
Operating Temperature: 32°F to 122°F ( 0°C to 50°C)
Not for use with sunlamps, saunas, or loads that could cause
personal injury if timed incorrectly

Timers

Ivory

White With Hold

Light Almond

EI200 Series

Electronic Countdown In-Wall Timers
•
•
•
•
•
•

Provides silent operation in time ranges from 5 minutes to 12 hours
Replaces single-pole switches in a variety of applications
Single button time selection
Operates most load types
Requires neutral wire
For use with decorator-style wall plate (not included)
Ivory

White

Model # Time Range

Hold

Model #

Time Range

EI200

Yes

EI200W

5,10,15, 30 Min.

Light Almond
Hold

Model #

Time Range

Hold

5, 10, 15, 30 Min.

Yes

EI200LA

5, 10, 15, 30 Min.

Yes

No

No
Yes

EI205*

5, 15, 30, 45, 60 Min.

No

EI205W*

5, 15, 30, 45, 60 Min.

EI205LA*

5, 15, 30, 45, 60 Min.

EI210

10, 20, 30, 60 Min.

Yes

EI210W

10, 20, 30, 60 Min.

Yes

EI210LA

10, 20, 30, 60 Min.

EI215**

15, 30, 60 Min., 2, 4 Hr.

No

EI215W**

15, 30, 60 Min., 2, 4 Hr.

No

EI215LA** 15, 30, 60 Min., 2, 4 Hr.

No

1, 2, 4, 8 Hr.

Yes

EI220LA

1, 2, 4, 8 Hr.

Yes

EI220

1, 2, 4, 8 Hr.

Yes

EI220W

EI230

2, 4, 8, 12 Hr.

Yes

EI230W

2, 4, 8, 12 Hr.

Yes

EI230LA

2, 4, 8, 12 Hr.

Yes

No

EI235W*

15, 30, 45, 60, 120 Min.

No

EI235LA*

15, 30, 45, 60, 120 Min.

No

EI235*

15, 30, 45, 60, 120 Min.

* Meets or exceeds ASHRAE 90.1 and IECC requirements for enclosed spaces.
** Meets or exceeds ASHRAE 90.1 requirements for enclosed spaces.

Ratings:

Input Voltage: 120 VAC, 60 Hz.
Resistive (heater): 15 A, 120 VAC, 1800 W
Tungsten (incandescent): 8.3 A, 120 VAC, 1000 W
Inductive Ballast: 8 A, 120 VAC, 1000 VA

Electronic Ballast: 500 VA
Motor: 1⁄4 HP, 120 VAC
Operating Ambient Temperature Range: 32ºF to 122ºF (0ºC to 50ºC)
Switch: Single Pole Single Throw
Warranty: Limited 1 year

Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly

www.intermatic.com

53

Timers

White With Hold

Ivory No Hold

Almond No Hold

FD Decorator Series
Auto-Off Timers

Standard Configuration

• No electricity required to operate
• Replaces any standard single or multi-gang wall switch
• Automatically limits ON time for energy consuming loads
• Quick and easy installation
• Time-saving up front terminal connection with teeter-type terminals
• For use with decorator or toggle style switch plates (not included)

Ivory

1 x SPST
Circuit

*See Note

Ivory

1 x DPST
Circuits
Ivory

Model # Time Cycle Switch

Hold

Model # Time Cycle Switch

Hold

Model # Time Cycle Switch

Hold

FD5M

5 Min.

SPST

No

FD4H

4 Hr.

SPST

No

FD36H

6 Hr.

FD15MC

SPST

No

FD6H

6 Hr.

SPST

No

*See
Note

No

15 Min.

FD15MH

15 Min.

SPST

Yes†

FD6HH

6 Hr.

SPST

Yes†

FD415M

15 Min.

DPST

No

FD30MC

30 Min.

SPST

No

FD12HC

12 Hr.

SPST

No

FD430M

30 Min.

DPST

No

FD30MH

30 Min.

SPST

Yes†

FD12HH

12 Hr.

SPST

Yes†

FD460M

60 Min.

DPST

No

FD60MC

60 Min.

SPST

No

FD32H

2 Hr.

No

FD46H

DPST

No

FD60MH

60 Min.

SPST

Yes†

*See
Note

6 Hr.

FD2H

2 Hr.

SPST

No

FD34H

4 Hr.

*See
Note

No

White

White

White

Model #

Time Cycle Switch

Hold

Model #

Time Cycle Switch

Hold

Model #

Time Cycle Switch

Hold

FD5MW

5 Min.

SPST

No

FD4HW

4 Hr.

SPST

No

FD430MW

30 Min.

DPST

No

FD15MWC

15 Min.

SPST

No

FD6HW

6 Hr.

SPST

No

FD460MW

60 Min.

DPST

No

FD15MHW

15 Min.

SPST

Yes

FD6HHW

6 Hr.

SPST

Yes

FD46HW

6 Hr.

DPST

No

FD30MWC

30 Min.

SPST

No

FD12HWC

12 Hr.

SPST

No

FD30MHW

30 Min.

SPST

Yes†

FD12HHW

12 Hr.

SPST

Yes†

FD60MWC

60 Min.

SPST

No

FD32HW

2 Hr.

No

FD60MHW

60 Min.

SPST

Yes†

*See
Note

FD2HW

2 Hr.

SPST

No

†

FD34HW

4 Hr.

*See
Note

†

No

Almond
Model # Time Cycle Switch

Hold

FD15MAC 15 Min.

SPST

No

FD30MAC 30 Min.

SPST

No

FD60MAC 60 Min.

SPST

No

† Hold feature enables auto shut-off override
*1 x SPST N.O. connected to 1 x SPST N.C. Switch can be configured at 1 x SPDT by jumpering input terminals together
Replacement knob information see page 154.

Ratings:
Resistive (heater): 20 A, 125 VAC, 60 Hz., 10 A, 250/277 VAC, 60 Hz.
Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly

54

Tungsten (incandescent): 7 A, 125 VAC
Motor: 1 HP, 125 VAC, 60 Hz, 2 HP, 250 VAC, 60 Hz.
Warranty: Limited 1 year

Timers

No Hold

Hold

Standard Configuration

1 x SPST
Circuit

*See Note

Hold† Single Pole Single Throw

1 x DPST
Circuits

FF Commercial Series
Auto-Off Timers

• No electricity required to operate
• Replaces any standard single or multi-gang wall switch
• Automatically limits ON time for energy consuming loads
• Quick and easy installation
• Time-saving up-front terminal connection with teeter-type terminals
• Brushed metal finish switch plate meets NEC requirements

No Hold Single Pole Single Throw

No Hold Single Pole Double Throw

Model #

Time Cycle

Switch

Model #

Time Cycle

Switch

Model #

Time Cycle

Switch

FF5MH

5 Min.

SPST

FF5M

5 Min.

SPST

FF315M

15 Min.

*See Note

FF15MH

15 Min.

SPST

FF15MC

15 Min.

SPST

FF330M

30 Min.

*See Note

FF30MH

30 Min.

SPST

FF30MC

30 Min.

SPST

FF360M

60 Min.

*See Note

FF60MHC

60 Min.

SPST

FF60MC

60 Min.

SPST

FF32H

2 Hr.

*See Note

FF6HH

6 Hr.

SPST

FF2H

2 Hr.

SPST

FF34H

4 Hr.

*See Note

FF12HHC

12 Hr.

SPST

FF4H

4 Hr.

SPST

FF36H

6 Hr.

*See Note

FF32HH

2 Hr.

*See Note

FF6H

6 Hr.

SPST

FF312H

12 Hr.

*See Note

FF34HH

4 Hr.

*See Note

FF12HC

12 Hr.

SPST

FF312HH

12 Hr.

*See Note

† Hold feature enables auto shut-off override
*1 x SPST N.O. connected to 1 x SPST N.C. Switch can be configured at 1 x SPDT
by jumpering input terminals together
Replacement knob information see page 154.

No Hold Double Pole Single Throw
Model #

Time Cycle

Switch

FF415M

15 Min.

DPST

FF430M

30 Min.

DPST

FF460M

60 Min.

DPST

FF46H

6 Hr.

DPST

FF412H

12 Hr.

DPST

Ratings:
Resistive (heater): 20 A, 125 VAC, 60 Hz, 10 A, 250/277 VAC, 60 Hz.
Tungsten (incandescent): 7 A, 125 VAC	
Motor: 1 HP, 125 VAC, 60 Hz., 2 HP, 250 VAC, 60 Hz.
Warranty: Limited 1 year
Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly

www.intermatic.com

55

Timers

B.

C.

E.

D.

A.

F.

KM2 Series

Mechanical In-Wall Timers
• Captive trippers with 20-minute switching interval
• Replaces standard wall switches
• Multiple plates available
• Reliable synchronous timer motor
• Easy wiring and installation
• Works with fluorescent and compact fluorescent lights
• 3-way (SPDT) switch available
• 3-way ON/AUTO/OFF override provides continuous
ON or OFF positions
• Heavy-duty 20 Amp rating
• 72 trippers provide 36 ON/OFF events per 24-hour period
• Automatic control of outdoor or indoor lighting, fans, pumps,
office equipment and other types of circuits

56

G.

Model #

Wall Plate

Configuration

Switch

Single-gang

­­­­—

SPST

Single-gang

3-Way

SPDT

B. KM2ST-2G

Two-gang

Toggle

SPST

C. KM2ST-3G

Three-gang

Toggle

SPST

D. KM2ST-4G

Four-gang

Toggle

SPST

E. KM2ST-2D

Two-gang

Decorator

SPST

F. KM2ST-3D

Three-gang

Decorator

SPST

G. KM2ST-2R

Two-gang

Receptacle

SPST

A. KM2ST-1G
KM2STU-1G

Ratings:
Switch Rating: 20 A, 120 VAC, 60 Hz. Resistive, 1 HP, 120 VAC
Operating Humidity: 0 to 95% non-condensing
Wiring Connections: (3) #14 AWG color coded lead wires:
Hot – Black, Switched – Red, Neutral – White
Warranty: 1 year

Timers

E1020
Heavy-Duty In-Wall Time Switch
• Includes two ON and OFF Trippers
• Dial accomodates a total of 12 ON and 12 OFF events
• Turns ON/OFF heavy-duty loads for energy savings,
security, and convenience
• Mounts to any standard junction box
• Neutral wire required
• Manual override
Model #
H. E1020

Switch

Color

SPST

Stonedust White Housing

Additional trippers (156EB1945A) sold separately page 153

Ratings:
Switch: SPST
Switch Rating: 125 VAC, 60 Hz., 1500 W Tungsten, 12 FLA, 15 A Resistive
Max. Wattage: 1800 W
Timing Cycle: Minimum ON time ½ hour, Maximum ON time 22 ½ hours
Minimum time between any two ON trippers (or 2 OFF trippers) is 2 hours
Dimensions: 4 ¼" (10.8 cm) H x 3 ¼" (9.5 cm) W x 1 3⁄8" (3.5 cm) D
Warranty: Limited 1 year

H.

E1010
Heavy-Duty In-Wall Time Switch
• Permanently attached ON/OFF tripper permits single
ON/OFF control every 24 hours
• 24-Hour dial divided in 30 minute increments
•	Turns ON/OFF heavy-duty loads for energy savings,
security, and convenience
•	Mounts to any standard junction box
• Neutral wire required
•	Manual override
Model #
J. E1010

Switch

Color

SPST

Stonedust White Housing

Ratings:
Switch: SPST
Switch Rating: 125 VAC, 60 Hz., 1500 W Tungsten, 12 FLA, 15 A Resistive
Max. Wattage: 1800 W
Timing Cycle: Minimum ON time ½ hour, Maximum ON time 22 ½ hours
Only 1 ON and 1 OFF Tripper
Dimensions: 4 1⁄4" (10.8 cm) H x 3 1⁄4" (9.5 cm) W x 1 3⁄8" (3.5 cm) D
Warranty: Limited 1 year

J.

www.intermatic.com

57

Timers

B.

A.

HB110 Series

Air Conditioner & Appliance Timer
•
•
•
•
•

 lugs directly into wall outlet
P
2 ON/OFF settings per day
3-prong grounded plug and receptacle
Manual override ON/OFF switch
Auto controls air conditioners, heaters, and
heavy-duty appliances
• Minimum ON/OFF times 30 mins.

C.
Model #

Voltage

Motor

Resistive

Inductive

Tungsten

Pilot Duty

Air Conditioner

A. HB112

240 VAC, 60 Hz

2 HP (8 FLA, 48 LRA)

15 A

8A

–

768 VA

8A

B. HB113

125 VAC, 60 Hz

1 HP (12 FLA, 72 LRA)

20 A

8A

1250 W

576 VA

12 A

C. HB114

240 VAC, 60 Hz

2 HP (8 FLA, 48 LRA)

20 A

8A

–

768 VA

8A

For additional trippers see page 154, (107SB189 red & 107SB192 black)
Limited 1-year warranty

58

Timers

D.
E.

TN311

DT620

Heavy-Duty Indoor Timer

Heavy-Duty Indoor Digital Timer

•G
 rounded receptacle and 3-prong plug
•3
 ON/3 OFF settings per day
• Plugs directly into wall outlet
Model #
D. TN311

•2
 grounded receptacles and grounded plug
• 28 ON/OFF settings
•A
 stronomic settings with automatic Daylight Saving Time adjustment

Voltage

Model #

125 VAC, 60 Hz

E. DT620

Rating:

Voltage

HP

125 VAC, 60 Hz

½

Rating:

15 A Resistive, 15 A Inductive, 1875 W Tungsten, 12 FLA, 72 LRA
Warranty: Limited 1 year

15 A Resistive, 12 A Inductive, 1000 W Tungsten, ½ HP Motor
Warranty: Limited 1 year

F.

TN111RM40

Plug-In Mechanical Timer
•
•
•
•

24-Hour timing
2 ON/OFF settings per day
Manual override
Rated for outdoor use in a Type 3R
outdoor enclosure
Model #
Voltage

F. TN111RM40
Additional Trippers see page 153
(107TN221 red, 107TN222 turquoise)

125 VAC, 60 Hz

G.

HB880R

Heavy-Duty Outdoor Digital Timer
•
•
•
•
•

2 grounded receptacles with 24" cord and grounded plug
Controls incandescent, fluorescent, LED, and CFL
Multiple programming options
AA battery backup
Astronomic settings with automatic Daylight Saving
Time adjustment
Model #

G. HB880R

Voltage

HP

120 VAC, 60 Hz

½

Rating:

Rating:

9.5 A Resistive, 1185 W Inductive
Warranty: Limited 1 year

15 A General Purpose, 1000 W Tungsten, 500 VA Electronic Ballast, 8.3 A Ballast (Inductive)
Warranty: Limited 1 year

www.intermatic.com

59

Sensors

{

9 Buttons

Hundreds of Options

M u l t i Wa v e

}

For more information on the MultiWave, see pages 114-117

Sensors

Bridge Lighting

Parking Lot Lighting
S tr e e t L i g h t ing
Highway Lighting

Bathroom Lighting
Hallway Lighting

Security Lighting
En t r y L i g h t i n g

Landscape Lighting

Outdoor Lighting
www.intermatic.com

61

Sensors
The LightMaster lighting control system gives YOU the power to
independently control two circuits based on the amount of natural light in an
area. Simply adjust the LightMaster foot-candle dials to a desired light level
and you instantly manage light the way you see it.
Imagine the energy savings. Instead of being stuck with a lighting control that
only turns lights ON/OFF in an area, you could have a LightMaster that can
turn lights ON in part of an area and OFF in another. This helps reduce your
energy consumption by as much as 50%.
LightMaster is ideal for any lighting application where operation is based on
natural light. The sensors can be installed in a 330-foot radius from the
controller in different accessible areas, such as a rooftop or a window, for easy
service access and reduced maintenance costs.
On top of the easy accessibility, LightMaster is virtually maintenance free
for the first 10 years of operation thanks to its durable sensor lifespan that
outlasts many thermal photocontrol sensors.
LightMaster also features unmatched accuracy with independent settings that
enable indoor lighting to stay off until natural lighting is reduced, while
outdoor lighting turns on when natural light is lost. The unique lighting control
system turns lights ON during inclement weather and avoids nuisance ON/OFF
switching caused from lightning or car lights. A single LightMaster can provide
a signal for up to 20 circuits to help conserve energy and promote a safer lit
area for customers and workers.

62

Dawn

Sensors

LightMaster in Action

Sunrise
At sunrise, no natural light is available, so lights are ON.

At dawn, natural light reaches the outer areas. Only inside area
lights remain ON. Energy costs are reduced by up to 50%.

Clouds Roll in

Noon

At noon, natural light is available, so lights are turned OFF.

A storm rolls in and reduces sunlight. LightMaster ensures all
areas are adequately lit, for maximum safety, no matter what
time of day.

Dusk

Sunset
At dusk, natural light still reaches the outer areas. Only inside
areas turn ON. Energy costs are reduced by up to 50%.

At sunset, the area is dark and the lights are ON.

Applications
•
•
•
•
•

Security Lighting
Atriums
ATM/Banks
Awnings, Shades, Blinds
Parking Garages

• Industrial Yards,
Off-Shore Rigs, Shipyards
• Site Lighting	
• 24-Hour Retail Convenience Store/
Service Establishments
www.intermatic.com

•
•
•
•

Perimeter Lighting	
Accessways, Walkways, Driveways
Exterior Lighting
Signage

63

Sensors

NEW

Kit includes LS2 Sensor

LM2-O-882T

LightMaster Control System with Timer
• 2-circuit control unit
• One sensor controls both circuits
• Independent light level and time delay adjustments for each circuit
• Timer turns lighting ON/OFF as needed to maximize energy savings
• 365-Day and holiday scheduling for maximum flexibility without additional
maintenance expenses
Model #

Sensor

LM2-O-882T LS2

Sensor Type Foot-Candle Range
Dark

10 to 1,000 fc

For enclosure options and dimensions, see page 151

64

Rating:

Enclosure: Type 3R Rainproof Enclosure
Input Voltage: 120 VAC
Operating Temperature:
	Control: -4°F to 131°F (-20°C to 55°C)
	
Sensor: -22°F to 158°F (-30°C to 70°C)
Switch Configuration: SPDT “dry” contacts per circuit
Resistive Rating: 10 A, 277 VAC per circuit
Inductive Rating: 8 A, 277 VAC per circuit
Relay: SPDT “dry” contacts per circuit
Sensor Variations: LS1 Transparent Sensor 0.2 to 50
Foot-Candles, Transparent case (IP65),
LS2 Dark Sensor 10 to 1,000 Foot-Candles,
Dark UV Filter case (IP65)
Sensor Time Delay: 0 to 100 seconds
Humidity Range:
	
Control: 0 to 95% RH non-condensing
	
Sensor: 0 to 100% RH

Sensors

Kit includes LS2 Sensor

Rating:
Enclosure: Type 3R Rainproof Enclosure
Input Voltage: 120 VAC
Operating Temperature:
	Control: -4°F to 131°F (-20°C to 55°C)
	
Sensor: -22°F to 158°F (-30°C to 70°C)
Switch Configuration: SPDT “dry” contacts per circuit
Resistive Rating: 10 A, 277 VAC per circuit
Inductive Rating: 8 A, 277 VAC per circuit
Sensor Variations: LS1 Transparent Sensor 0.2 to 50
Foot-Candles, Transparent case (IP65), LS2 Dark Sensor
10 to 1,000 Foot-Candles, Dark UV Filter case (IP65)
Sensor Time Delay: 0 to 100 seconds
Humidity Range:
	
Control: 0 to 95% RH non-condensing
	
Sensor: 0 to 100% RH

LM2-O-120

LightMaster Control System
• 2-circuit control unit
• One sensor controls both circuits
• One sensor can provide a signal for up to 10 LightMaster control modules
• Independent light level and time delay adjustments for each circuit
Model #

Sensor Sensor Type

Foot-Candle Range

LM2-O-120

LS2

10 to 1,000 fc

Dark

For enclosure options and dimensions, see page 151

www.intermatic.com

65

Sensors
A.

B.

C.

D.

PC Series	

LightMaster Control Modules with Sensor
• Transparent and dark sensor types available to accommodate your distinct light-level needs
• Adjustable light-level sensitivity control
• Surface/DIN Rail mountable
• 0-to-100-second adjustable sensor time delay
Sensor Type

Foot-Candle Range

A. PC2-120-LS1

Model #

LS1

Sensor

Circuits
2

Transparent

0.2 to 50 fc

B. PC2-120-LS2

LS2

2

Dark

10 to 1,000 fc

C. PC1-120-LS1

LS1

1

Transparent

0.2 to 50 fc

D. PC1-120-LS2

LS2

1

Dark

10 to 1,000 fc

For ratings, See pages 66 & 67
For enclosure options and dimensions, see page 151

66

Sensors

E.

F.

PC1-120 & PC2-120	

LightMaster Control Modules
• 1 or 2 circuit control units
• 1 light-level setpoint per circuit
• Adjustable dials for setting foot-candle levels
• 0-to-100-second sensor time delay adjustment dials
• Surface/DIN Rail mountable

Model #

Circuits

E. PC1-120

1

F. PC2-120

2

Dusk-to-Dawn Control
Wall

Position sensor
with arrow
facing wall

LS1 or LS2

Interior Lighting Control
(Daylight Harvesting)

H.

G.

LS Series	

LightMaster Ambient Light Sensors
• Transparent and opaque sensors for all lighting applications
• One sensor can provide a signal for up to 10 LightMaster control modules
• Accurate, reliable measurement for precise foot-candle light-level settings

Wall

Model # Sensor

Position sensor
with arrow
facing sunlight

LS2

Sensor Type Foot-Candle Range

Mounting Type

G. LS1

LS1

Transparent

0.2 to 50 fc

1

H. LS2

LS2

Dark

10 to 1,000 fc

1

⁄2" conduit fitting
⁄2" conduit fitting

For ratings, see pages 66 & 67
For enclosure options and dimensions, see page 151

www.intermatic.com

67

Sensors

B.

A.

K4000C Series

Thermal-Type Photo Controls with Fixed Position Mounting
•
•
•
•

Fits into standard outlet box, post lamp or wall packs
Model K4321C includes a weatherproof wallplate with neoprene gasket
Includes 3 ⁄8" npsm with 3 ⁄4" long stem locking nut and washer gasket
2-year warranty
Model # Watts Tungsten VA Ballast*

A. K4021C

Input Voltage Agency/Listing

1800

1000

120 VAC

K4023C

3100-4150

1700-2300

208-277 VAC

K4027

5205

2880

347 VAC

K4035

7200

4000

480 VAC

B. K4321C†

1800

1000

120 VAC

–

*The ballast wattage rating is based upon a 50% power factor
†UL listing for K4321C applies to the entire plate assembly when properly mounted to an
approved outdoor junction box

Rating:

Inductive Ballast: 8.3 A
Tungsten: 15 A
Activation: 1-5 FC ON, 3-15 FC OFF (without shield)
Operating Temperature: -40°F to 158°F (-40°C to 70°C)
Color: Gray
Lead Length: 9" leads
Dimensions:
Plate – 4 ½" (11.4 cm) H x 2¾" (7.0 cm) W
Mechanism – 15 ⁄16" (3.3 cm) W x 113 ⁄16" (4.6 cm) L x 13 ⁄16" (2.1 cm) D

Accessory for Fixed Position
Thermal-Type Photo Controls
6LV1352

Light Shield
• Fits K40 Series

68

Model #

Qty.

6LV1352

1

Sensors

K4100 & K4400 Series
Thermal-Type Photo Controls
with Stem Mounting

•	Single and multi-volt models
•	Dusk-to-Dawn lighting control
•	Delay feature prevents unwanted
OFF switching
• Lightlevel slide adjustment
• Cadmium sulfide photocell
• 1 ⁄2"-14 threaded stem
• Washer gasket and locking nut included

Model # Watts Tungsten VA Ballast
C. K4121C

C.

Amps Tungsten Amps Ballast

Input Voltage

D.

Agency/Listing

Warranty

1800

1000

15

8.3

120 VAC

2 year

K4123C

3100-4150

1700-2300

15

8.3

208-277 VAC

2 year

K4127

5205

2880

15

8.3

347 VAC

K4135

7200

4000

15

8.3

480 VAC

–

2 year

K4141C

3000

3000

25

25

120 VAC

–

1 year

D. K4421M*

2 year

1800

1000

15

8.3

120 VAC

2 year

K4423M*

3100-4150

1700-2300

15

8.3

208-277 VAC

2 year

K4136M*

2000-4625

1800

16.7

15

120 or 277 VAC

2 year

*Models with “M” suffix have heavy-duty die cast housing

Rating:
Dimensions: 1 9 ⁄16" (4.0 cm) Sq x 3" (7.6 cm) L
Power Consumption: Under 1 W
Operating Temperature: -40˚F to 158˚F (-40˚C to 70˚C)

Screw-In Photo Control
•
•
•
•

Controls interior and exterior lights
ON at dusk, OFF at dawn
Accommodates any incandescent light 
Limited 1-year warranty

Model #

Voltage

Watts

NE1C

120 VAC/60 Hz

150 Max

Note: Not for use with CFL and LED lights

www.intermatic.com

69

Sensors

K4200 Series

Thermal-Type Photo Controls with Stem &
Swivel Mounting
•
•
•
•
•

Single and multi-volt models
Delay feature prevents unwanted OFF switching
Cadmium sulfide photocell
Dual temperature compensating bi-metal and composite resistor
Washer gasket and locking nut included
Photo Eye on Side with Light-Level Adjusment
Model # Watts
Tungsten

A. K4221C

VA Ballast VAC

Agency/Listing Warranty

1800

1000

120

2 year

K4223C

3100-4150

1700-2300

208-277

2 year

K4227

5205

2880

347

2 year

7200

4000

480

K4235

–

2 year

Photo Eye on Top (for spot/flood fixtures)

B.

Model # Watts
Tungsten
B. K4251
K4253
C. K4236C

VA Ballast VAC

Agency/Listing Warranty

1800

1000

120

1 year

3100-4150

1700-2300

208-277

1 year

1800-4150

1000-2300

120-277

2 year

Rating:

A.

Tungsten Amps: 15
Ballast Amps: 8.3
Power Consumption: Averages under 2 W
Activation: 1-5 FC ON, 3-15 FC OFF (photo eye clear models with shield)
Operating Temperature: -40˚F to 158˚F (-40˚C to 70˚C)
Lead Length: 6"
Dimensions: K4200 Series:: ½"– 14 threaded swivel, 1 9⁄16" (4.0 cm) Sq. x 5 ½" (14.0 cm) L
K4236C: 5 ¾" (14.6 cm) H x 3" (7.6 cm) ø
K4251 and K4253: 4" (10.2 cm) H x 1 3⁄8" (3.5 cm) ø
K4200 Series A. only: 6 1 ⁄4" (15.9 cm) ø

C.

K4500 Series

Thermal-Type Photo Controls with Locking-Type Mounting
•
•
•
•
•
•
•
•

Dusk-to-Dawn lighting control
Cadmium sulfide photocell
Easy-to-install
Standard 3-prong locking-type plug connections
Delay feature prevents unwanted OFF switching
Dual temperature compensating bi-metal and compositor resistor
Sonic welded case and lens seal out moisture
2-year warranty
Model #

Watts Tungsten VA Ballast VAC 50/60 Hz Agency/Listing

D. K4521

1800

1000

120

K4522

3600

2000

240

K4524

3100

1700

208

K4533

4155

2300

277

K4535

7200

4000

480

Rating:

D.

70

Tungsten Amps: 15
Ballast Amps: 8.3
Power Consumption: Averages under 2 W

Activation: 1-5 FC ON, 3-15 FC OFF
Operating Temperature: -40˚F to 158˚F (-40˚C to 70˚C)
Dimensions: 3 1 ⁄4" (8.3 cm) H x 3" (7.6 cm) ø

Sensors

LC4500 Series

Thermal-Type Photo Controls
• Locking-Type Mounting
• Controls street lighting and other applications requiring twist and
lock plug connection
• Integral high impact thermoplastic housing
• Complies with ANSI C136.10 Standard
• Dual temperature compensating bi-metal and composite resistor
• Dusk-to-Dawn lighting control
• Delay feature prevents unwanted OFF switching
• 2-year warranty
Model #

Watts
Tungsten

VA Ballast Voltage Agency/Listing
50/60 Hz

1800

1000

120

LC4523

3100-4155

1700-2300

208-277

LC4527

5205

2880

347

LC4535

7200

4000

480

LC4536C

1800-4155

1000-2290

120-277

LC4521LA*

1800

1000

120

LC4523LA* 3100-4155

1700-2300

208-277

LC4535LA* 7200

4000

480

LC4536LAC* 1800-4155

1000-2290

120-277

E. LC4521C

E.

*Models equipped with a 2400 volt open type spark gap arrester.

Rating:

Color: Translucent with color-coded
Tungsten Amps: 15
band for voltage identification
Ballast Amps: 8.3
Dimensions: 2 3 ⁄4" (7.0 cm) H x 3" (7.6 cm) ø
Power Consumption: Averages under 1 W
Activation: .5 FC minimum ON, 15 FC maximum OFF

Accessories for Photo Controls

G.

F.

H.

Model #

Description

Rating

F.

K122

Outdoor Locking-Type Receptacle with Pole Bracket

15 A Max, 480 Volt Max.

G.

K121

Locking-Type Receptacle with 9" Leads

15 A Max, 480 Volt Max.

K121-30

Locking-Type Receptacle with 30" Leads

15 A Max, 480 Volt Max.

H.

K4500

Shorting Cap

15 A Max, 480 Volt Max.

J.

K42-SW-A

Swivel Assembly for K4100, K4200 Series

–

J.
Agency Listing

–

Rating:
Pole Bracket Adapters: For use with all locking-type photo controls
Shorting Cap K4500: 105-480 Volts; replaces locking-type photo control to complete circuit
Dimensions: 2 3⁄4" (7.0 cm) H x 3" (7.6 cm) ø

www.intermatic.com

71

Sensors

K1100, K1200 Series

Relay-Type Photo Controls
with Locking-Type or Adjustable-Stem Mounting
• Instant ON/OFF switching with two mounting types
• K1100 models have three 6" color-coded leads
• K1200 models have 2400 volt open-type spark gap arrester
and standard 3-prong connector
• Adjustable stem models can be set at any angle up to 80 degrees
• 2-year warranty
Adjustable Stem
Model #

Voltage

Amps Tungsten Amps Ballast

A. K1121

105-130 VAC, 50/60 Hz

15

15

K1122

208-240 VAC, 50/60 Hz

7.5

7.5

Twist Lock

A.
Voltage

Amps Tungsten Amps Ballast

B. K1221

Model #

105-130 VAC, 50/60 Hz

15

8.3

K1222

208-240 VAC, 50/60 Hz

7.5

7.5

Rating:
Watts Tungsten: 1800
VA Ballast: 1800
Activation: 1 FC ON, 3 – 10 FC OFF
Operating Temperature: -40˚F to 158˚F (-40˚C to 70˚C)
Dimensions: K
 1100 Series: 5 3⁄4" (14.6 cm) H x 3" (7.6 cm) ø, 1⁄2" – 14 NPT Stem
K1200 Series: 3 3⁄4" (9.5 cm) H x 3" (7.6 cm) ø

B.

LC2000
Low Cost Relay-Type Photo
Control with Locking-Type Mounting
•
•
•
•
•

Complies with ANSI C136.10 Standard
Easy-to-install plug-in locking-type connector
Heavy-duty relay designed for long life switching
Instant ON/OFF switching
2-year warranty
Model #

C. LC2000

Voltage

Watts Tungsten VA Ballast

110-277 VAC, 50/60 Hz

1000

Rating:

C
72

Activation: 1 to 3 FC ON, Turn OFF to turn ON ratio is 4
Dimensions: 2 3⁄16" (5.6 cm) H x 3 3⁄16" (8.1 cm) ø

1800

Electronic Photo Controls Locking-Type
• Specifically designed to provide long life and superior surge
protection when used with LED luminaires
• Twice the lifespan of comparable photo controls
• Photo control relay exceeds 10,000 operations at full load
• Zero crossing preserves contacts for longer lifespan
• Conformal coated board protects against environmental conditions
• Complies with ANSI C136.10-2010 Standard
• CSA certified to both UL & CSA standards
• High-tech silicon light sensing for consistent, repeatable operation
• Filters out all sources of infrared light to match
human eye response
• 370 Joule MOV
• 8-year manufacturer’s warranty
Model #
F. EK4536

Voltage

Photo Sensor

120-277 VAC, 50/60 Hz

Silicon - IR filtered

NEW

Sensors

EK4536

Rating:
Tungsten: 1000 W
Inductive Ballast: 1800 VA
Activation Type: Instant ON – 2-5 Sec. Delay OFF
Light Level: 1.2-3 FC ON, 2- 5 FC OFF
Operating Temperature: -40°F to 158°F (-40°C to 70°C)

F.

D.

Model # Timer Voltage
D. K4536SS

–

E. K4536SST Yes

Photo Sensor

120-277 VAC Silicon - IR
filtered
120-277 VAC Silicon - IR
filtered

Rating:
Tungsten: 1000 W
Ballast: 1800 W
Activation: 3 FC ON, 2-4 FC OFF
Operation: Instant ON, 10 Second Delay OFF
Operating Temperature: -40°F to 158°F (-40°C to 70°C)
Color: Translucent with color coded band for voltage identification
Dimensions: 2 3⁄4" (7.0 cm) H x 3" (7.6 cm) ø

Timer Controls

E.

K4536SS & K4536SST

Solid-State Photo Controls Locking-Type
• Dusk-to-Dawn lighting control
• Electronically calibrated – does not require resetting
• Reliable control of street lighting and other applications requiring
plug-in twist and lock connection
• Complies with ANSI C136.10 Standard and Federal and Dark Sky Initiative
• Fits in ordinary locking-type socket
• Automatically resets after power outage
• Retro-fits any standard locking-type photo control
• 430 Joule MOV
• 3-year warranty
www.intermatic.com

73

Sensors

IOS-CMP-U
• Zero crossing 
• Adjustable time delay
• Adjustable ambient light sensor
• Suitable for use with electronic ballast
• Limited 2-year warranty
Model #

Voltage

Mounting Height Coverage

IOS-CMP-U

120-277 VAC

8'

1,200 sq. ft.

Rating:
Voltage: 120-277 VAC, 60 Hz.
Adjustable Light Level: 10fc - 150fc
Adjustable Time Delay: 15 sec. - 30 min.
Coverage Pattern: 360º 1200 sq. ft.
Incandescent: 800 W, 120 VAC 60 Hz.
Inductive Ballast: 800 VA, 120 VAC, 60 Hz. 1600 VA at 277 VAC, 60 Hz.
Electronic Ballast: 800 VA, 120 VAC, 60 Hz. 1600 VA at 277 VAC, 60 Hz.
Motor: ¼ HP, 120 VAC, 60 Hz.
Operating Temperature: 32°F to 131°F (0°C to 55°C)

IOS-HB-U

Lens 2: 2,800 sq. ft.

• Zero crossing 
• Adjustable time delay
• Adjustable ambient light sensor
• Suitable for use with electronic ballast
• Limited 2-year warranty
Model #

Voltage

Mounting Height

Coverage

IOS-HB-U

120-277 VAC

15'-50'

1200 sq. ft. (Lens 1)
2800 sq. ft. (Lens 2)

Rating:
Voltage: 120-277 VAC, 60 Hz.
Adjustable Light Level: 10fc - 150fc
Adjustable Time Delay: 15 sec. - 30 min.
Coverage Pattern: (Lens 1) 360º 1200 sq. ft. (Lens 2) 360º 2800 sq. ft.
Incandescent: 800 W, 120 VAC, 60 Hz
Inductive Ballast: 800 VA, 120 VAC, 60 Hz. 1600 VA at 277 VAC, 60 Hz.
Electronic Ballast: 800 VA, 120 VAC, 60 Hz. 1600 VA at 277 VAC, 60 Hz.
Motor: ¼ HP, 120 VAC, 60 Hz
Operating Temperature: 32°F to 131°F (0°C to 55°C)

IOS-CMP-LV
• Low Voltage remote mounted sensor
• Adjustable time delay
• Walk through detection
• Adjustable ambient light sensor
• Powered by IOS-PP24 power pack
• Limited 2-year warranty
Model #

Voltage

Mounting Height

Coverage

IOS-CMP-LV

24 VDC

8'

1,200 sq. ft.

Rating:
Voltage: 24 VDC
Adjustable Light Level: 10fc - 150fc
Adjustable Time Delay: 15 sec. - 30 min.
Operating Temperature: 32°F to 131°F (0°C to 55°C)

IOS-PP24
• Zero crossing
• Controls up to 6 IOS-CMP-LV
• Suitable for use with electronic ballast
• Multiple switching operations
• Limited 2-year warranty

74

Model #

Voltage

IOS-PP24

120-277 VAC

Rating:

Voltage: 120-277 VAC, 50/60 Hz.
Incandscent: 15 A, 120 VAC, 50/60 Hz.
Inductive Ballast: 20 A, 120/240/277 VAC, 50/60 Hz.
Motor: 1 HP, 120/240 VAC, 50/60 Hz.
Operating Temperature: 32°F to 131°F (0°C to 55°C)

Sensors

IOS-DDR / DSR

In-Wall Occupancy/Vacancy Sensor
• Zero crossing
• Self-Adaptive feature automatically adjusts time
delay based on occupant patterns
• “Walk-through” feature detects when areas are briefly
occupied and turns lighting OFF based on a shorter time
delay to maximize energy savings
• No neutral required
• Passive Infrared technology
• Standard decorator wall plate
• Adjustable ambient light sensor
• Suitable for use with electronic ballast
• Limited 5-year warranty
Model #

Color
2 Circuit

A. IOS-DDR-WH

White

1 Circuit
B. IOS-DSR-WH

White

IOS-DSR-IV

Ivory

Ratings:

B.

Inductive Ballast: 800 VA at 120 VAC,
1600 VA, 277 VAC
Motor: ¼ HP, 120 VAC
Operating Temperature:
32°F to 131°F (0°C to 55°C)

Voltage: 120/277 VAC, 60 Hz.
Time Delay: 15 sec. - 30 min.
Coverage Area: 180°, 1200 sq. ft.
Light Level: 30 Lux-Daylight
Incandescent: 800 W, 120 VAC

A.

IOS-DOV Series

In-Wall Occupancy/Vacancy Sensors
• Zero crossing
• Automatic ON/OFF Control
• Passive Infrared technology
• Adjustable ambient light sensor
• Standard decorator wall plate
• Suitable for use with electronic ballast
• Optional night light for vacancy sensing
• Limited 5-year warranty
Model #
C. IOS-DOV-WH
IOS-DOV-NL-WH
D. IOS-DOV-IV
IOS-DOV-NL-IV

Night Light

Color

Requires Neutral

No

White

Yes

Yes

White

Yes

No

Ivory

Yes

Yes

Ivory

Yes

Ratings:
Voltage: 120 VAC, 60 Hz.
Incandescent: 800 W, 120 VAC
Inductive Ballast: 800 VA, 120 VAC
Resistive: 800W, 120 VAC
Time Delay: 15 sec. - 30 min.

C.

Coverage Area: 180°, 1200 sq. ft.
Motor: ¼ HP, 120 VAC
Operating Temperature:
32°F to 131°F (0°C to 55°C)

D.
www.intermatic.com

75

Sensors

Which Sensor
Works Better for You?
Occupancy Sensors
Lights automatically turn ON when entering a room
Lights automatically turn OFF when room is vacant
Vacancy Sensors
Requires manually turning lights ON when entering a room
Lights automatically turn OFF when room is vacant

IOS-DPBIF2 Series
In-Wall Vacancy Sensors

• Can be used with electronic or magnetic ballasts
• Standard decorator wall plate included
• Limited 2-year warranty
Model #

Color

Requires Neutral

IOS-DPBIF2-WH

White

Yes

IOS-DPBIF2-IV

Ivory

Yes

Ratings:

Inductive Ballast: 500 VA, 120 VAC
Motor: 1⁄8 HP, 120 VAC
Operating Temperature:
32°F to 131°F (0°C to 55°C)

Input Voltage: 120 VAC, 60 Hz.
Adjustment: Manual
Coverage Area: 150°, 980 sq. ft.
Tungsten: 500 W, 120 VAC
Resistive: 500 W, 120 VAC

IOS-DSIF / DSIMF Series
In-Wall Occupancy Sensors

• Automatic ON/OFF Control
• Standard decorator wall plate included
• Ambient light sensor
• Limited 2-year warranty
Model #

Color

Requires Neutral

IOS-DSIF-WH

White

Yes

IOS-DSIF-IV

Ivory

Yes

Electronic Ballast

Inductive Ballast
IOS-DSIMF-WH

White

No

IOS-DSIMF-IV

Ivory

No

Ratings:
Input Voltage: 120 VAC, 60 Hz.
Adjustment: Manual
Coverage Area: 150°, 980 sq. ft.
Resistive: 500 W, 120 VAC

76

Tungsten: 500 W, 120 VAC
Inductive Ballast: 500 VA, 120 VAC
Motor: 1⁄8 HP, 120 VAC
Operating Temperature:
32°F to 131°F (0°C to 55°C)

Sensors

IOS-DPBIF / DPBIMF Series
In-Wall Occupancy Sensors

• Automatic ON/OFF control
• Standard decorator wall plate included
• Ambient light sensor
• Limited 2-year warranty
Model #

Color

Requires Neutral

Electronic Ballast
IOS-DPBIF-WH

White

Yes

IOS-DPBIF-IV

Ivory

Yes

IOS-DPBIMF-WH

White

No

IOS-DPBIMF-IV

Ivory

No

Inductive Ballast

Ratings:
Input Voltage: 120 VAC, 60 Hz.
Adjustment: Manual
Coverage Area: 150°, 980 sq. ft.
Tungsten: 500W, 120 VAC
Resistive: 500 W, 120 VAC

Inductive Ballast: 500 VA, 120 VAC
Motor: 1⁄8 HP, 120 VAC
Operating Temperature:
32°F to 131°F (0°C to 55°C)

How often have you stubbed your toe in a dark room
or entered your home with every light ON?
Intermatic’s occupancy and vacancy sensors can finally put
an end to these common annoyances. The intuitive sensors
make sure room lights turn ON/OFF when needed, and not
a second more. Take the pain out of your toes and your
wallet today with an occupancy or vacancy sensor.

www.intermatic.com

77

CAN YOU DO 4,000 THINGS AT ONCE?

For more information on the ET90000, see pages 12-14

Hour Meters

Boilers Construction Waste oil furnaces
Custom UL Panels
Indust rial air compressors
Irrigation pumps Escalat ors Generators
Battery chargers Elevators Power Supplies
M edi cal / D e n ta l Automotive Fire / Rescue
Schools Central Vacuums Manufacturing facilities
Wastewater pump panels Production automation
79

Hour Meters

FWZ53 Series
AC Hour Meters

E22587
LR44080

• Non resettable
• Optional gasket to achieve IP54 rating
• White numerals on black background with tenths/hundredths
numerals in yellow

A.

Model #

Input Voltage

Frequency

FWZ53-120/50U

120 VAC

50 Hz

FWZ53-120U

120 VAC

60 Hz

FWZ53-220/50U

220 VAC

50 Hz

FWZ53-24U

24 VAC

60 Hz

Ratings:

Bezel: 2.09" x 1.02" (53 mm x 26 mm)
Capacity: 99,999.99 hours
Digits: 0.16" high numerals
Power Consumption: 1 VA
Operating Temperature: -40°F to 160°F (-40°C to 72°C)
Termination: Combination ¼" spade and screw clamp
Mounting: Flush-panel retainer mounted (2) 0.150" holes for #6 screws
Panel Opening: 1.50" x 1.00" rectangular (38 x 25 mm)

A.

FWZ55 Series
AC Hour Meters

E22587
LR44080

• Non resettable
• Optional gasket to achieve IP54 rating
• White numerals on black background with tenths/hundredths
numerals in yellow

B.

Model #

Input Voltage

Frequency

FWZ55-120U

120 VAC

60 Hz

FWZ55-220/50

220 VAC

50 Hz

FWZ55K-120U

120 VAC

60 Hz

FWZ55K-220/50

220 VAC

50 Hz

FWZ55K-240U

240 VAC

60 Hz

Ratings:

Bezel: 2.36" x 1.36" (60 mm x 34.5 mm)
Capacity: 99,999.99 hours
Digits: 0.16" high numerals
Operating Temperature: -40°F to 160°F (-40°C to 72°C)
Power Consumption: 1 VA
Termination: Combination ¼" spade and screw clamp. Rear access screw
terminals available (models with “K” suffix)
Mounting: Flush-panel retainer mounted with slip-on plastic retaining bracket
Panel Opening: 2.06" x 1.08" rectangular (52 mm x 27.5 mm)

B.

FWZ53 & FWZ55
Series Gasket
80

Model #

Description

G-55U

Gasket for FWZ53 & FWZ55

G-53U

Gasket for FWZ53

Hour Meters

Rugged and Tough
Hour Meters built to withstand
up to an environmental rating
of IP54
C.

FWZ72 Series
AC Hour Meters

E22587
LR44080

• Non resettable
• Optional gasket to achieve IP54 rating
• White numerals on black background with tenths and hundredths
numerals in yellow

Model #

Input Voltage

Frequency

Color

120 VAC

60 Hz

Black

24 VAC

60 Hz

Black

D. FWZ72B-120U

120 VAC

60 Hz

Blue, Silver, Clear

FWZ72B-240U

240 VAC

60 Hz

Blue, Silver, Clear

FWZ72C-120

120 VAC

60 Hz

Clear Frosted

FWZ72K-240U

240 VAC

60 Hz

Black

C. FWZ72-120U
FWZ72-24U

E.

D.

Ratings:

Bezel: 2.83" round (72 mm), 3 hole
Capacity: 99,999.99 hours
Digits: 0.16" high numerals
Power Consumption: 1VA
Operating Temperature: -40°F to 160°F (-40°C to 72°C)
Termination: Combination ¼" spade and screw clamp
Rear access screw terminals available (models with “K” suffix)
Mounting: Flush-panel mounted with three 0.185" holes for #8 screws
Panel Opening: 1.75" round (44.5 mm) or 1.50"x 1" rectangular
(38 mm x 24 mm)

E.

FWZ72 Series Gasket

Model #

Description

G-72U

Gasket for FWZ72

www.intermatic.com

81

Hour Meters

Get to Know The UWZ Series AC Hour Meters
There is no mistaking a Grässlin by Intermatic UWZ Series AC Hour
Meter. The non-resettable meters meet the IP20 environmental rating
for indoor applications and come standard with an accurate
synchronous motor. All models have the trademark light gray color
with white numerals on black background and yellow tenths and
hundredths numerals. An orange dial adjacent to the hundredths
digit provides running indication.

UWZ48 Series
Surface Mount

E22587
LR44080

• For use where terminal protection is not required
• Easy-to-install socket base
• Can be installed in panels or mounted indoors
Model #

Input Voltage

UWZ48-24U

24 VAC, 60 Hz

UWZ248-120U

120 VAC, 60 Hz

UWZ48-240U

240 VAC, 60 Hz

Ratings:

Bezel: 1.89" x 1.89" (48 mm x 48 mm)	
Capacity: 99,999.99 hours
Digits: 0.16" high numerals
Power Consumption: 1VA

Termination: Screw lugs
Operating Temperature:
-40°F to 160°F (-40°C to 72°C)
Accuracy synchronous to network

UWZ48A Series

Enclosed Surface Mount

E22587
LR44080

• For use where terminal protection is required
• Terminal cover for added safety
• Easy-to-install socket base
Model #

Input Voltage

UWZ48A-24U

24 VAC, 60 Hz

UWZ248A-120U

120 VAC, 60 Hz

Ratings:

Bezel: 1.89" x 1.89" (48 mm x 48 mm)
Capacity: 99,999.99 hours
Digits: 0.16" high numerals
Power Consumption: 1VA

82

Termination: Screw lugs
Operating Temperature:
-40°F to 160°F (-40°C to 72°C)
Accuracy synchronous to network

Hour Meters

UWZ48E Series

E22587

Flush Mount with Bracket

LR44080

• Fits into 1.79" x 1.79" (45.5 mm x 45.5 mm) cut-out
• Flush mount panel thickness up to 0.35" (9 mm)
• Fits square or round 72 mm opening with optional bezel
• Unit is secured by a plastic slip-on retaining bracket
Model #

Input Voltage

UWZ48E-120U

120 VAC, 60 Hz

UWZ48E-120/50U

120 VAC, 50 Hz

UWZ48E-220/50U

220 VAC, 50 Hz

UWZ48E-24U

24 VAC, 60 Hz

UWZ48E-24/50U

24 VAC, 50 Hz

UWZ48E-240U

240 VAC, 60 Hz

Rating:

Termination:
Combination 1⁄4" spade and screw clamp
Operating Temperature: -40°F to 160°F
(-40°C to 72°C)
Accuracy synchronous to network

Bezel: 1.89" x 1.89" (48 mm x 48 mm)
Capacity: 99,999.99 hours
Digits: 0.16" high numerals

UWZ48V Series
DIN Rail Mount

E22587
LR44080

• Snap-on socket base
• Unit can be fitted to DIN Rail quickly and easily
Model #

Input Voltage

UWZ48V-24U

24 VAC, 60 Hz

UWZ48V-120U

120 VAC, 60 Hz

Rating:

Operating Temperature:
-40°F to 160°F (-40°C to 72°C)
Accuracy synchronous to network

Bezel: 1.89" x 1.89" (48 mm x 48 mm)
Capacity: 99,999.99 hours
Digits: 0.16" high numerals
Termination: Screw lugs

UWZ52E Series

Flush Mount with Bracket

E22587
LR44080

• Fits into 1.79” x 1.79” (45 mm x 45 mm) cut-out
• Round face fastened with a plastic slip-on retaining bracket
• Flush mount panel thickness up to 0.35" (9 mm)
Model #

Input Voltage

UWZ52E-120U

120 VAC, 60 Hz

Rating:

Bezel: 2.28" (58 mm) diameter
Capacity: 99,999.99 hours
Digits: 0.16" high numerals

UWZ48E Series
Accessories
Bezels

Termination: Combination ¼"
spade and screw clamp
Operating Temperature:
-40°F to 160°F (-40°C to 72°C)
Accuracy synchronous to network

Model #

Description

Color

BEZ-55BLACKU

55 mm Bezel

Black

BEZ-55GRAYU

55 mm Bezel

Gray

BEZ-72U

72 mm Bezel

Gray

BEZ-72PU

72 mm Bezel with 3 pins for round 3-bolt hole openings

Gray

www.intermatic.com

83

Hour Meters

GZ40AU

DC Hour Meter
• Flush mount
• Operates on DC Voltages
• Measures up to six digits to determine usage
• Dustproof and splashproof construction
Model #
A. GZ40AU

Input Voltage
10-80 VDC

Rating:

SAE Bezel: 2.31" diameter (59 mm)
Capacity: 99.999.9 hours
Digits: 6 – 0.125 high numerals, Hours: white on black, Tenths:
red on white
Power Consumption: .03 W, 12VDC; .70 W, 48 VDC
Temperature: –22°F to 150°F (–30°C to 65°C)
Vibration Resistance: 10-75 Hz, 1-8 g
Protected From: Reverse Polarity, inductive switching
Termination: ¼" spade terminals
Environmental Rating: IP66

GZ52BU

DC Hour Meter
• Operates on DC Voltage
• Measures up to six digits to
determine usage
• Quartz stabilized vibration proof
• LED operation indicator
• Dustproof and splashproof
construction
Model #

Input Voltage

B. GZ52BU

8-30 VDC

GZ40BU

DC Hour Meter
• Surface mount
• Operates on DC Voltages
• Measures up to six digits to
determine usage
• Dustproof and splashproof
construction
Model #
C. GZ40BU

84

Input Voltage
10-80 VDC

Rating:

Current Consumption: < 3 mA,12 VDC
Accuracy: ±0.5 sec/day at 20°C
Mechanical Movement: 2-Phase Step Motor
Display: 6 Digits (99999.9 Hours)
Bezel: 2.28" (58 mm)
Electrical Connection: 1⁄4" Quick Connectors
Polarity Protection: Reverse Polarity-Diode
Mounting: Flush (screw adj.)
Operating Temperature: -40°F to 185°F
(–40º C to 85°C)
Storage Temperature: -40°F to 194°F
(–40º C to 90°C)
Environmental Rating: IP65
Shock Resistance: DIN EN60068-2-27
Vibration Resistance: DIN EN60068-2-64

Rating:

3-Hole Bezel: 2.80" diameter (72 mm)
Totally sealed enclosure
Capacity: 99.999.9 hours
Digits: 6 – 0.125 high numerals, Hours: white on
black, Tenths: red on white
Voltage: 10-80 VDC
Power Consumption:
.03 W, 12 VDC, 70 W, 48 VDC
Temperature:
–22°F to 150°F (–30°C to 65°C)
Vibration Resistance:
10-75 Hz, 1-8 g
Termination: ¼" spade terminals
Protected From: reverse polarity, inductive
switching
Environmental Rating: IP66

The RZ Series Vibration Hour Meters convert vibrations into energy to
drive the minute hand. The sensitive hour meters can operate from the
slightest vibrations, such as a moving car.

A.

Model #

Installation

Quantity

RZ52HU

Horizontal

1

RZ52VU

Vertical

1

Ratings

Dimensions: (Ø x D) 2.28" x 2.05" (58 mm x 75 mm)
Panel Cutouts: Ø 2.05" (52 mm)
Mounting Depth: 2.95" (75 mm)
Ambient Temperature: 5˚F to 140˚F (-15˚C to 60˚C)
Protection Quality: IP65
Accuracy: +/-3% at uninterrupted operation
Counting Range: 99,999 hours
Mounting: Flush mount
Mounting Position: RZ 52 H to 45˚ RZ 52 V to 45˚

Hour Meters

NO Power Needed...

RZ Series

Vibration Hour Meters
• No electrical connection required
• Automatic mechanism converts vibrations into energy to drive meter
• Horizontal and vertical installation
• Front panel is dustproof and waterproof
• High-sensitivity level

www.intermatic.com

85

Lighting Controls

For more information on the In-wall timers, see pages 48-55

Defrost / HVACR

Commercial Refrigeration Systems
Food processing facilities

Food equipment

Free standing coolers

Food Storage facilities

Blast ch i l l e r s Ice Machines Food Display cases
Supermarkets

Walk-in coolers

Beverage equipment

Reach-in coolers
87

Defrost / HVACR

NEW

Set in 3
Easy Steps
1) Set Time

2) Set Defrost

3) Set Defrost
Duration

G8000 Series

Durable Mechanical Defrost Timer

151753 UL 873, UL917
CSA 24, CSA 177
Refrigeration Controller

• Long life welded silver contacts rated at 40 Amps, 2 HP rating
• Encapsulated time module design prevents dust and dirt buildup
• Heavy-duty synchronous motor
• Mechanism snaps into many existing enclosures and brackets
• Heavy-duty steel enclosure with knockouts on bottom, back, and sides
• Up to six defrost cycles per day
• Includes 4 trippers
• Defrost termination from 4 to 110 minutes in 2 minute increments
• Works with external temperature or pressure sensors
• Positive switch action slide bar
• Quick and easy installation
• 2-year warranty

Electrical Ratings: 40 A Resistive, 2 HP
Pilot Duty: 1000VA
Enclosure: Type 1 Indoor

Model #

Description

Input Voltage

Switch Type

G8045-00

Time Initiated. Time Terminated.

120 VAC, 60 Hz

1N.O./1N.C.

G8045-20

Time Initiated. Time Terminated.

208-240 VAC, 60 Hz

1N.O./1N.C.

G8145-00

Time Initiated. Termperature, Pressure or Time Terminated.

120 VAC, 60 Hz

1N.O./1N.C.

G8145-20

Time Initiated. Termperature, Pressure or Time Terminated.

208-240 VAC, 60 Hz

1N.O./1N.C.

For enclosure dimensions, see page 146
88

Ratings:

Snaps into existing enclosures

Flexible
Scheduling

Battery
Backup

Auto-Voltage
No DIP Switch

LED
Load Status
Indicator

Defrost / HVACR

No Tools Required

Type 3R
Enclosure

Large
Screws
Terminals

Heavy-Duty
40 Amp
Contacts

Ground Lug
Termination

Moisture
Resistant
Circuit Board

DTAV40E2

Electronic Defrost Control
Ratings:
Contact Switch Rating:
40A Resistive, 120-240 VAC
2 HP, 240VAC: 1 HP, 120 VAC
Wiring Connections:
Screw box lug terminals. Up to one #8AWG Wire
MInimum ON/OFF: 1 minute
Environmental Ratings:
Operating Temperature Range:
-13ºF to 104ºF (-25ºC to 40ºC)
Operating Humidity: 0-95% RH non-condensing
Electrical Life: 50,000 operations at full load
Warranty: 1 year

E10694

• Time Initiated. Temperature, Pressure or Time Terminated
• Automatically adjusts voltages between 120-240 VAC, 50/60 Hz
• 24-Hour/7-Day flexible scheduling increases system efficiency
• Rechargeable battery backup (with 2500-hour carryover)
• Simple to program
• Heavy-duty 40 Amp contact rating
• LED indictors for defrost and refrigeration cycles
• To-the-minute defrost duration improves system efficiency
• Large screw terminals for easy wiring #8 awg
Model #

Voltage

Enclosure

DTAV40E2

120, 240 VAC, 50/60 Hz

Type 3R Plastic

For enclosure dimensions, see page 151
www.intermatic.com

89

Defrost / HVACR

No Tools Required

Snaps into existing enclosures
Captive
Trippers
Can’t Be Lost

True Clock
Face
LED
Load Status
Indicators
Auto-Voltage
No Dip Switch

Moisture
Resistant
Circuit Board

Ground Lug
Termination
Large Screw
Terminals
90

Heavy-Duty
40 Amp Contacts

Defrost / HVACR

B.

A.
C.

DTAV40 Series

Auto-Voltage Defrost Timer
•
•
•
•
•
•
•
•
•
•

E10694

Time Initiated. Temperature, Pressure or Time Terminated
Replaces over 40 competitive models
Automatically adjusts voltages between 120 and 240 VAC
No tools required, mounts in existing enclosures
Heavy-duty 40 Amp contact ratings
Programmable defrost times in 15-minute intervals
Moisture resistant conformal coated board
Independently programmed defrost cycles
LED indicators for defrost and refrigeration cycles
True clock face for quick, easy and accurate setting

Ratings:

Model #

Auto Voltage: 120-240 VAC, 60 Hz
A. DTAV40
Quartz: 120-240 VAC 50/60 Hz
Electrical Ratings: 40 A Resistive,
B. DTAV40IM
120-240 VAC 1 HP, 120 VAC, 2 HP, 240 VAC
Operating Humidity: 0-95% RH, non-condensing
C. DTAV40M
Min. ON/OFF: 15 minutes
DTAV40Q
Max. ON/OFF: 23 hours, 45 minutes
Electrical Life: 50,000 operations at full load
DTAV40Q-M
Wire Size: #8 AWG
Temp Rating: -40ºF to 104ºF (-40ºC to 40ºC)
Quartz Temp Rating: -4ºF to 104ºF (-20ºC to 40ºC)
Warranty: 1 year
Model #

DT-B

Input Voltage

Enclosure

Timer Type

120, 208/240 VAC

Type 3R Plastic

Synchronous

Battery Backup
No

120, 208/240 VAC

Type 1 Metal

Synchronous

No

120, 208/240 VAC

Mechanism Only

Synchronous

No

120, 208/240 VAC

Type 3R Plastic

Quartz

Yes (7-Day Carryover)

120, 208/240 VAC

Mechanism Only

Quartz

Yes (7-Day Carryover)

Accessory
Description
Bracket accessory for mounting

For enclosure dimensions, see page 151.

www.intermatic.com

91

Defrost / HVACR

Grässlin by Intermatic’s Vapor Tight Light Fixtures never blink at
extreme conditions. They feature a powder coat finish that
maximizes durability and a seamless, die-cast design that
prevents moisture penetration. A heat-resistant glass globe
protects the enclosed light.
The vapor tight light fixtures are great for areas with extreme
climate conditions, such as construction sites, subways, bridges,
tunnels, freezers, walk-in coolers, and wastewater and sewage
treatment plants.

A.

B.

C.

Vapor Tight Fixtures
• Industrial grade, fully enclosed with gasket
• Rugged, seamless, die-cast construction
• Powder coat finish for maximum durability
• Heat-resistant glass globe
• CFL compatible
• Protective guard prevents damage of glass globe

92

Model #

Wattage

Voltage

Mounting Style

A. VPXG-11-CGI

100

120 VAC

Ceiling

B. VPKG-11-CGI

100

120 VAC

Pendant

C. VWG-01-CGI

100

120 VAC

Wall

Lamp not included

Surge

Retail Space Light Industrial Manufacturing
Servers P umps Motors Facilities
Health Care Facilities Lighting Ballasts
Institutional Buildings Single Residences Modems
Telecom Equipment Multi-Family Residences
Security Systems Televisions Computers
Hospitality Commercial Office Space
HVAC
s

93

Surge

What is Surge Protection?
ANSI/IEEE defines common electrical disturbances that occur in modern facilities as: Voltage, Waveform, Current Waveform,
and 100 kHz Ring Wave. Depending on the proximity of the equipment to your power entry points, the severity increases. As
the transient surge event propagates throughout your building, it degrades your electronic components with excess voltage
and current.
ANSI/UL 1449 3rd Edition Surge Protection Definitions
As of September 30, 2009 ANSI/UL 1449 3rd Edition replaced UL 1449 2.5. SPDs manufactured after September 30, 2009 need
to meet ANSI/UL 1449 3rd Edition standards. Any products manufactured before this date may still be sold as a UL 1449 2.5
compliant product. Electrical components in devices are susceptible to transient surge overvoltage and can create significant
downtime, equipment replacement, and costly repairs.

Surge Protective Devices (SPDs) are classified into Type 1, Type 2 and Type 3.
TYPE 1: P
 ermanently connected SPD is installed between the secondary transformer and the line
side of the service equipment.
TYPE 2: Permanently connected SPD is installed on the load side of the service equipment over current device.
TYPE 3: Cord connected SPD is installed at the point of use.

Industrial

Service
Entrance
Meter

Type 1

Type 2

Type 3

Before
Panel

After
Panel

Direct
Plug-in

Residential

Service
Entrance
Meter

94

Type 1

Type 2

Type 3

Before
Panel

After
Panel

Direct
Plug-in

1. Desired Geographic Location of the SPD
a. How much exposure is there to utility grid switching?
b. Is the location susceptible to brownouts or frequent utility power switching?

Surge

Guidelines to consider when choosing a Surge Protective Device (SPD)

2. Point of Installation. What type of SPD do you need?
See SPD classifications on previous page.

Common Voltage Configurations
The wiring diagrams below illustrate the common voltage configurations for Intermatic surge products. Locate the desired voltage
configuration and surge protector part number, and then go to the applicable product page to order the desired item(s).

120 VAC
Single Phase

120, 240 VAC
Single Phase
(Split Phase)

AG3000
AG2401C3

IG1240RC3
IG3240RC3
IG1300-2T-1C3
IG1300-4T-2C3
AG3000

277, 480 VAC
Three Phase Wye

AG4803C3

120, 208 VAC
Three Phase Wye

120, 240 VAC
Three Phase HLD

AG2083C3

AG2403C3

(High Leg Delta)

347, 600 VAC
Three Phase Wye

277, 480 VAC
Single Phase

AG6503C3
AG6503L3

AG4801C3

NOTE: All SPDs protect against surges that travel along the electrical pathway and are not applicable to direct lightning strikes that
travel down non-electrical paths. Be sure to have at least a 20 amp dual pole breaker(s) to help prevent the circuits from shorting.
Type 1 SPDs are normally mounted before panels, which would not include a breaker.

Surge Glossary
Surge: A sudden, sharp increase of current or voltage within electric circuits.
Surge Protective Device (SPD): A device used to divert or limit a surge on a piece of equipment. SPDs were previously
known as Transient Voltage Surge Suppressors or Secondary Surge Arresters.
Short Circuit Current Rating (SCCR): The measurement of how much current the electrical system can supply during a
fault condition. This value determines where an SPD may be installed. (Listed on the product)
Nominal Discharge Current: Peak value of the current through the SPD having a current wave shape of 8/20 where the
SPD remains functional after 15 surges. (Listed on the product)
Nominal System Voltage: The voltage level at which a system normally operates. Nominal system voltages include,
but are not limited to, 120, 208, 240, 277, 347, 480, 600 VAC. (Listed on the product)
Modes of Protection: Electrical paths within a system that an SPD defends against surge events, such as Line to Neutral
(L-N), Line to Ground (L-G), Line to Line (L-L) and Neutral to Ground (N-G). (Listed on the product)
Voltage Protection Rating (VPR): The value assigned by UL which specifies the measured limited voltage value of the
SPD. VPR rating is formally known as the suppressed voltage rating. (Listed on the product)
Maximum Continuous Operating Voltage (MCOV): The maximum RMS voltage that may be applied to each mode of a
surge protection device. (Listed on the product)
Three Phase WYE: Consists of 3 hot lines or phases, commonly referred to as X, Y, Z, a neutral and ground wire for a
total of 5 wires in a power distribution cable.
High Leg Delta: Type of electrical service connection for three phase electric power installations. It is one of the several
types of three phase service setups. It is used to provide an additional voltage that is half the phase to phase voltage.

www.intermatic.com

95

Surge

Why Surge Protection
Matters to You
Surge Protection is one of the most overlooked safeguards. Most
people protect their electronics but leave more valued equipment
unsecured from surges and spikes. An estimated $250-$500 million* a
year is lost from property damage caused by power surges and spikes.
Don't be the next victim. Safeguard your equipment with Intermatic
Surge Protection. Intermatic offers a complete line of surge protective
devices for single family residences, commercial office spaces, HVACR
equipment, and pool/spas. It covers everything from irrigation and
farm equipment to pumps, lighting fixtures, traffic lights, and motors.

Why take the costly risk?

Invest in peace of mind with Intermatic surge protective devices.

96

*National Lightning Detection Network

Surge

AG3000

HVAC Surge Protective Device

AG3000

HVAC Surge Protective Device
• Meets ANSI UL1449 3rd Edition Standards
• 120/240 VAC single split phase SPD for use on a variety of HVAC equipment
• Green LED protection indicator
• Type 4x enclosure
• 1⁄2" x 20 threaded nipple (weatherproof and UV resistant)
• TPMOV™ technology
• 3 modes of protection
• 3 leads
• 18" lead length
• 10 gauge leads
• 3-year warranty
• $7,500 connnected equipment warranty
Model #

Service
Voltage

SPD
Type

Nominal
MCOV*
Discharge
Current

Wiring
SCCR** Voltage Protection
Configuration
Rating (VPR)

AG3000

120/240 VAC

1 or 2

10kA

L1, L2, L/N-G

L-N

L-L

150V

300V

L-N/G
20kA

600

N-G

L-L
900

* MCOV Maximum Continuous Operation Voltage
* *SCCR Short Circuit Current Rating

www.intermatic.com

97

Surge

IG1200RC3

Plastic Housing
• Type 1 or 2 SPD applications
• Green LED indicator provides status of protection
• Type 3R rainproof enclosure
• 5.65" H x 4.18" W x 3.33" D
• 3 modes of surge protection (L1-N, L2-N, L1-L2)
• 3-year product warranty
• $7,500 connected equipment warranty
for 3 years on appliances and electronics

A.

IG1240RC3

Plastic Housing
•Type 1 or 2 SPD applications
• Green LED indicator provides status of protection
• Type 3R rainproof enclosure
• 5.65" H x 4.18" W x 3.33" D
• 6 modes of surge protection:
L1-N, L2-N, L1-G, L2-G, N-G, L1-L2
• 5-year product warranty
• $10,000 connected equipment warranty
for 5 years on appliances and electronics

B.

IG3240RC3
Metal Housing

• Type 1 or 2 SPD applications
• Green LED indicator provides status of protection
• Type 3R rainproof enclosure
• 5.28" H x 4.4" W x 3.25" D
• 6 modes of surge protection
L1-N, L2-N, L1-G, L2-G, N-G, L1-L2
• 10-year product warranty
• $25,000 connected equipment warranty
for 10 years on appliances and electronics

C.
Model #

Service
Voltage

No. of
Leads

Lead
Wiring
Length Config.

A. IG1200RC3

120, 240 VAC

B. IG1240RC3

120, 240 VAC

4

30"

L1, L2, N, G

20 kA

C. IG3240RC3

120, 240 VAC

4

30"

L1, L2, N, G

20 kA

3

30"

* MCOV Maximum Continuous Operating Voltage
**SCCR Short Circuit Current Rating
†Applies to all models

98

Nominal
MCOV*
Discharge
Current

L1, L2, N/G

20 kA

SCCR**

L-N/G
50 kA

150 L-N, N-G†
300 L-L, L-G†

Voltage Protection
Rating (VPR)
L-N

L-G

N-G L-L

700

1200

50 kA

700

1200 700

1200

50 kA

700

1200 700

1200

Surge

IG1300-2T-1C3
• Type 2 SPD applications
• 12 gauge wire
•	Provides protection for 2 telephone lines (Analog phone line,
modem, or DSL) and 1 coax line (cable TV, cable Internet or
Satellite TV)
•	Type 3R outdoor rainproof enclosure for indoor/outdoor
installations (9.38" H x 5.25" W x 4" D)
•6 modes of surge protection:
L1-N, L2-N, L1-G, L2-G, N-G, L1-L2
• 5-year product warranty
•	$10,000 connected equipment warranty for 5 years on
appliances and electronics
D.

IG1300-4T-2C3
• Type 2 SPD applications
• 12 gauge wire
•	Provides protection for 4 telephone lines (Analog phone line,
modem, or DSL) and 2 coax lines (cable TV, cable Internet or
Satellite TV)
• Type 3R outdoor rainproof enclosure for indoor/outdoor
installations (9.38" H x 5.25" W x 4" D)
•6
 modes of surge protection:
L1-N, L2-N, L1-G, L2-G, N-G, L1-L2
•	5-year product warranty
•	$10,000 connected equipment warranty for 5 years on
appliances and electronics
E.

Model #

Service
Voltage

No. of Lead
Wiring
Leads Length Config.

Nominal MCOV*
Discharge
Current

D. IG1300-2T-1C3 120, 240 VAC

4

24"

L1, L2, N, G

20 kA

E. IG1300-4T-1C3 120, 240 VAC

4

24"

L1, L2, N, G

20 kA

150 L-N, N-G†
300 L-L, L-G†

SCCR**

Voltage Protection
Rating (VPR)
L-N/G

L-N

L-G

N-G

L-L

50 kA

700

1200

700

1200

50 kA

700

1200

700

1200

*MCOV Maximum Continuous Operating Voltage
**SCCR Short Circuit Current Rating
†Applies to all models

Flushmount Kit
• For IG1200RC3, IG1240RC3 and IG3240RC3
• Includes mounting plate, screws and mounting bracket
• Easy to use
Model #

HxW

F. IG1240FMP33

7" x 7.5"

G. IG3240FMP33

7" x 7.5"

F.
www.intermatic.com

G.
99

Surge

Protect Your
Outdoor Equipment
Irrigation equipment, pumps,
lighting fixtures, traffic signaling
devices, farm equipment,
HVACR controls and motors

AG Series

Surge Protective Devices
• SPD Type 1 / Type 2 applications
• For outdoor installations on service entrances and utility meter cabinets
• UV resistant polycarbonate housing with ½" x 20" nominal nipple
• Type 4 outdoor rainproof enclosure
• Nominal Discharge Current 20 kA
• Green LED protection indicator
• Limited 1-year warranty
Model #

Poles

Lead
Length

Wiring
Config.

AG1BRKT Mounting Bracket

MCOV*
L-N/G

SCCR**
L-L

Voltage Protection
Rating (VPR)
L-N/G

L-L

Service Voltage 120/240 VAC
AG24013

Single Phase

18"

L1, L2, N/G

150

300

50kA

700

1200

AG2401C3

Single Phase

18"

L1, L2, N/G

150

300

50kA

700

1200

50kA

700

1200

Service Voltage 208 VAC
AG2083C3 3 Pole, 4 Wire

18"

L1, L2, L3, N/G

150

300

Service Voltage 277/480 VAC
AG48013

Single Phase,
2 Pole, 3 Wire

18"

L1, L2, N/G

320

640

50kA

1200

2000

AG4803C3 3 Pole, 4 Wire

18"

L1, L2, L3, N/G

320

640

50kA

1200

2000

AG6503C3 3 Pole, 4 Wire

18"

L1, L2, L3, N/G

420

840

50kA

1500

2500

AG6503L3

36"

L1, L2, L3, N/G

420

840

50kA

1500

2500

Service Voltage 347/600 VAC
3 Pole, 4 Wire

Service Voltage 120/208/240 VAC
AG2403C3 3 Pole, 4 Wire

18"

L1, L2, L3, N/G

*MCOV Maximum Continuous Operating Voltage
**SCCR Short Circuit Current Rating
To order AG1BRKT Mounting Bracket, see page 154

100

150 L1/L3 - N/G
270 L2 - N/G

300 L1-L3
420 L1/L3 - L2

50kA

700 L1/L3 - N/G
1000 L2 - N/G

1200 L1-L3
1500 L1/L3-L2

Surge

B.

A.

C.

Surge Protective Strips
Type 3 SPD Point-of-Use
• For heavy-duty industrial use
•	14 gauge SJT power cord with molded plug
• LED protection indicator
• Electrical rating: 15 Amp 125 VAC
• 15 Amp resettable breaker
• 5-year warranty
D.

E.

Without EMI/RFI Noise Filtration
Model #

Coverage Warranty Cord Length Outlets

VPR*

L-N/L-G/N-G

A. IG112463†

$10,000

6'

4

700/600/600

IG112663†

$10,000

6'

6

700/600/600

$10,000

10'

6

700/600/600

B.

C. IG112663BLK10†

With EMI/RFI Noise Filtration
Model #
D. IG20663
IG206153
E. IG20B123
IG2012B153

Coverage Warranty Cord Length Outlets VPR*

L-N/L-G/N-G

$25,000

6'

6

400/400/500

$25,000

15'

6

400/400/500

$5,000

6'

6

700/600/600

$5,000

15'

6

700/600/600

*Voltage Protection Rating
†Comes with illuminating ON/OFF switch

Mounting Bracket Plate
•	Secure mounting bracket for all IG strips
• Extruded aluminum alloy
Model #

LxW

24EG5133

6" x 1.95"

www.intermatic.com

101

Surge

Phone, Modem and DSL
Surge Protective Devices
A. IG2TM
•
•
•
•
•
•
•

Protects 2 lines
Type 1 enclosure
Tip-To-Ground, Tip-To-Ring and Ring-To-Ground Modes
40 kA surge protection per line
#24 to #16 gauge AWG
Gas tube protection 350 VDC breakdown
UL497A

A.

B. IG4TM
•
•
•
•
•
•
•

Protects 4 lines
Type 1 enclosure
Tip-To-Ground, Tip-To-Ring and Ring-To-Ground Modes
40 kA surge protection per line
#24 to #16 gauge AWG
Gas tube protection 350 VDC breakdown
UL497A

B.

C. IG2T3R
•
•
•
•
•
•
•

Protects 2 lines (expandable to 12 Lines)
Type 3R rainproof enclosure
Tip-To-Ground, Tip-To-Ring and Ring-To-Ground Modes
40 kA surge protection per line
#24 to #16 gauge AWG
Gas tube protection 350 VDC breakdown
UL497A

Model #

C.
102

Lines

Wire Configuration

Location

A. IG2TM

2

4

Indoor

B. IG4TM

4

8

Indoor

C. IG2T3R

2 (up to 12)

4 (up to 24 wire)

Indoor/Outdoor

Surge

Standalone Antenna,
Cable Satellite, Cable Internet
Surge Protective Devices

E.

D.

IG1CM & IG1CM3R

Model #

• 10 kA surge protection per line
• Gas tube protection 90 VDC breakdown

Lines

Thread Type

Location

Enclosure

D. IG1CM

1 (up to 2)

F

Indoor

—

E. IG1C3R

1 (up to 6 coax)

F

Indoor/Outdoor

Type 3R

Surge Accessories

F.

F.

G.

H.

Model #

Decription

Lines

For Use In

IG2T

Spare telephone/modem/DSL Internet protection module

2

IG2TM, IG1CM, IG2T3R, IG1C3R, IG1300-2T-1C3

G. IG1C

Spare coax cable protection module

1

IG1CM, IG1C3R, IG2TM, IG4TM, IG2T3R

H. IGFlush

Flush Mount Kit

—

IG2TM, IG4TM, IG1CM

www.intermatic.com

103

Switch It Up!

For more information on the G8000, see page 88

Weatherproof
Covers

Residential
Commercial
Industrial
Agricultural
Signage
Sports Fields
105

Weatherproof

All Intermatic Weatherproof Covers meet the 2011 NEC current code requirements
Code Requirements:
Intermatic‘s line of Type 3R receptacle covers ensures compliance with 2011 NEC Article 406.9 (B1) which requires that 15 and 20 ampere,
125 and 250 volt receptacles installed in a wet location have an enclosure that is weatherproof whether or not the attachment plug cap is
inserted. They are designed to meet the 2011 NEC Article 210-60(b), which requires that receptacles installed behind beds in hotels and
motels, be protected with a suitable guard.

Type 3R

Specifications:

Meets UL and CSA Cold Impact Testing at -60˚F (-51˚C)

All covers can be used for flush mount, surface mount or FS junction box mounting
Cover: Clear (gray or white on selected models) UV stabilized polycarbonate
Mounting Base and Inserts: Black UV stabilized polycarbonate
Gasket: Neoprene – 1⁄8" (4.8 mm) thick with slits for mounting screws

These Flexi-Guard Inserts fit single-gang or double-gang models of clear, gray, or white
plastic, and extra-duty die-cast designs. Each insert package can be purchased separately. All
weatherproof covers come with Flexi-Guard inserts and mounting screws. The double-gang
inserts (WP217, WP101, WP102, WP107, and WP213) include a special double-gang gasket.

WP17
Single-Gang Flexi-Guard Inserts
3 standard Flexi-Guard inserts – 16 possible configurations
• Standard in all Flexi-Guard single-gang covers
• 3 separate inserts can be configured into 16 different receptacles or switches
• Converts to either toggle or round receptacle sizes: 1.375," 1.625," 1.75," or 2.125"

WP217
Double-Gang Flexi-Guard Inserts
6 Standard Flexi-Guard inserts – 70 possible configurations
•C
 an be combined to make the illustrated configurations
for double-gang covers
• Converts to either toggle or round receptable sizes: 1.375" or 1.625"

Additional Inserts Available for Flexi-Guard Series:

106

WP101

WP102

WP107

Double-Gang Duplex

Double-Gang GFCI

Double-Gang Round
1.375", 1.625", 1.75"

WP213

Double-Gang Round
1.375", 1.625", 1.75"

A.

B.

D.

Weatherproof

Meets/Exceeds All 2011 NEC Requirements
for Extra-Duty Applications and Wet Locations*

C.

F.

E.

Extra-Duty Die-Cast Covers
Single and Double-Gang

Single-Gang WP17 Inserts

• Type 3R enclosure rating
• Lockable hasp
• Die-Cast aluminum construction
• Impact rated
• Sleek industrial design
• Reinforced hinge
• Can be used with 12 gauge cord sets. Recommended for 14 gauge or
lighter cord sets
Single-Gang Vertical
Model #

Flexi-Guard Inserts

Length

Width

Height

Depth

A.

WP3110MXD

WP17

6.375"

3.875"

2.875"

2 3⁄4"

B.

WP1010MXD

WP17

6.375"

3.875"

3.25"

3 1⁄8"

C.

WP1250MVXD

WP17

6.375"

3.875"

4.75"

4 5⁄8"

Length

Width

Height

Depth

Double-Gang
Model #

Flexi-Guard Inserts

D.

WP1030MXD

WP217

6.312"

5.75"

3.25"

3 1⁄8"

E.

WP1250MXD

WP217

6.312"

5.75"

4.75"

4 5⁄8"

Length

Width

Height

Depth

4.375"

5.75"

3.25"

3 1⁄8"

Double-Gang WP217 Inserts

Single-Gang/Horizontal
Model #
F.

WP1010HMXD

Flexi-Guard Inserts
WP17

*2011 NEC Article 406.9 (B1)

www.intermatic.com

107

Weatherproof

B.

A.

C.

E.

D.

Plastic In-Use Covers
Single-Gang

• Complies with 2011 NEC Article 406.9 (B1)
• Heavy-duty polycarbonate construction
• Vertical/horizontal hinge configuration
• Pre-adhered gasket
• Meets requirements for Cold Impact Testing at -60°F (-51°C)
• Packaged with 3 patented inserts for GFCI, duplex, toggle, or round receptacles
• Limited 1-year warranty
Cord Diam.

Max. Cord Gauge

Depth

Color

Lockable Hasp Diam.

A. WP3100C*

Model #

WP17

0.5"

(2) 14 or (1) 12 Gauge

2 3⁄4"

Clear

For .125" lock

B. WP3103C**

WP17

0.5"

(2) 14 or (1) 12 Gauge

3

2 ⁄4"

Clear

For .125" lock

C. WP1100C

WP17

0.5"

(2) 14 or (1) 12 Gauge

3

2 ⁄4"

Clear

For .250" lock

D. WP1100WC

WP17

0.5"

(2) 14 or (1) 12 Gauge

2 3⁄4"

White

For .250" lock

WP17

0.5"

(2) 14 or (1) 12 Gauge

5

3 ⁄8"

Clear

For .250" lock

E. WP1110GC

WP17

0.5"

(2) 14 or (1) 12 Gauge

3 ⁄8"

Gray

For .250" lock

WP1110WC

WP17

0.5"

(2) 14 or (1) 12 Gauge

3 5⁄8"

White

For .250" lock

WP1110C

Flexi-Guard Inserts

* Hidden hinge
**Includes 3/0 Adapter Plate for 3" Round Box

108

5

Weatherproof

H.

G.

F.

K.

L.

J.

M.

Hinge Configuration Vertical
Model #

Cord Diam.

Depth

WP17

G. WP1000GC
H. WP1010C

F.

J.

WP1000C

WP1000WC

Flexi-Guard Inserts

Color

0.5"

1

2 ⁄4"

Clear

WP17

0.5"

2 1⁄4"

Gray

WP17

0.5"

3 1⁄8"

Clear

WP17

0.5"

2 1⁄4"

White

Hinge Configuration Horizontal
Model #
K. WP1000HC
L.

WP1000HGC

M. WP1010HC

Flexi-Guard Inserts

Cord Diam.

Depth

WP17
WP17
WP17

Color

0.5"

1

2 ⁄4"

Clear

0.5"

2 1⁄4"

Gray

0.5"

3 ⁄8"

Clear

1

Plastic In-Use Covers
Single-Gang

• Complies with 2011 NEC Article 406.9 (B1)
• Heavy-duty polycarbonate construction
• Vertical and horizontal mount
• Meets Cold Impact Testing requirements
at -60˚F (-51˚C)
• Limited 1-year warranty

Note: See page 106 for inserts

www.intermatic.com

109

Weatherproof
A.

B.

C.

D.

E.

Plastic In-Use Covers
Double-Gang or Single-Gang

• Complies with 2011 NEC Article 406.9 (B1)
• Heavy-duty polycarbonate construction
• Vertical hinge configuration
• Pre-adhered gasket
• 3 inserts for GFCI, duplex, toggle, or round receptacles
• Meets Cold Impact Testing requirements at -60°F (-51°C)
Model #

Flexi-Guard Inserts Cord Diam. Max. Cord Gauge

A. WP1020C

WP101 & WP102

0.5"

(2) 14 or (1) 12 Gauge

2 1⁄4"

Clear

B. WP1020GC

WP101 & WP102

0.5"

(2) 14 or (1) 12 Gauge

2 1⁄4"

Gray

C. WP1020WC

WP101 & WP102

0.5"

(2) 14 or (1) 12 Gauge

2 ⁄4"

White

D. WP1030C

WP101 & WP102

0.5"

E. WP1050

WP101 & WP102

0.8"

1

(2) 14 or (1) 12 Gauge

1

3 ⁄4"

Clear

(2) 14 or (1) 10 Gauge

4 3⁄4"

Clear

Note: Lockable hasp accepts up to .125" (3.175 mm) diameter shank

110

Depth Color

WP101 & WP102 Inserts

Weatherproof

F.

G.

H.

J.

K.

L.

Plastic In-Use Covers
Double-Gang

• Complies with 2011 NEC Article 406.9 (B1)
• Heavy-duty polycarbonate construction
• Vertical hinge configuration
• Pre-adhered gasket
• 3 inserts for GFCI, duplex, toggle, or round receptacles
• Meets Cold Impact Testing requirements at -60°F (-51°C)
Cord Diam. Max. Cord Gauge

Depth

Color

F. WP1150C

Model #

Flexi-Guard Inserts
WP17

0.8"

(2) 14 or (1) 10 Gauge

4 3⁄4"

Clear

G. WP1220C

WP217

0.5"

(2) 14 or (1) 12 Gauge

1

2 ⁄4"

Clear

H. WP1220GC

WP217

0.5"

(2) 14 or (1) 12 Gauge

2 ⁄4"

Gray

J. WP1220WC

WP217

0.5"

(2) 14 or (1) 12 Gauge

2 1⁄4"

White

K. WP1230C

WP217

0.5"

(2) 14 or (1) 12 Gauge

1

3 ⁄8"

Clear

L. WP1250C

WP217

0.8"

(2) 14 or (1) 10 Gauge

4 ⁄4"

Clear

www.intermatic.com

1

3

111

For more information on the extra duty weatherproof covers, see page 107

Pool & Spa
Controls

Irrigation
Saunas

Pools

Koi Ponds
Filters

Fountains

Spas

Pumps

Ponds
H eat e rs

Sprinklers
113

Pool & Spa

Nine Buttons,
Hundreds of Options
Convenient, Easy-to-Use
Wireless Pool or Spa Controls
The MultiWave Wireless Control System is the best
solution for pool or spa automation. It features a
wireless remote and receiver for on-demand
control from the palm of your hand. It also controls
five circuits for single and two-speed pumps, along
with the Pentair® variable speed pumps. Choose
between the standard MultiWave that controls a
single body of water, or the PE34065RC that controls
pool and spa combination systems. The MultiWave
is easily upgradeable from any Intermatic mechanical
timer or energy-efficient pump.

MultiWave Control System

TITLE

20

• Wireless control for pool/spa equipment
• Controls 5 circuits
• Operates single, two, and variable-speed pumps
• 24-hour timing with 3 ON/OFF events per circuit
• Includes receiver, wireless remote, water and air temperature sensors,
(3) AA batteries, equipment labels, and flathead screwdriver
• Controls filters, lights, cleaners, and heaters
COMPLIANT

Model #
A. PE653RC

Enclosure
Type 3R steel indoor/outdoor

Rating:

Control Supply: 120, 240 VAC, 50/60 Hz., 5 W max.
Circuit 1: 20 A Resistive (17 FLA, 80 LRA), 120, 240 VAC 50/60 Hz.
Circuits 2-5: 15 A Resistive (10 FLA, 60 LRA), 120, 240 VAC, 50/60 Hz.
Enclosure Dimensions (HxWxD): 9 3 ⁄8" x 5 ½" x 3 ¾" (23.8 cm x 13.97 cm x 9.5 cm)
Knockouts: Combination ½" - ¾" (1) on back, (1) each side, (2) on bottom
Warranty: 2 year
Pentair® is a registered trademark of Pentair Ltd.

A.
114

Pool OR Spa

Pool & Spa

MultiWave Accessories

B.

C.

PE953

PE653
MultiWave 5-Circuit Wireless Receiver

MultiWave Wireless Remote

• Ideal for adding to an existing enclosure installation
• Works with PA122 water temperature sensor and
1789PA28A air sensor
• Communicates with variable-speed pumps,
chlorinators, and water temperature sensors
• Ideal for upgrading from any Intermatic
mechanical timer
• 2-year warranty

• Water-resistant backlit display
• Displays time of day, equipment status, water and air
temperatures, and ON/OFF schedules
• On-demand control of PE653 circuits, temperatures,
and other Z-Wave devices
• Operates single, two, and variable-speed pumps
and motorized valve actuators
• 2-year warranty

Model #
B. PE653

Description

Qty.

Panel Mount Receiver

1

Model #
C. PE953

Description

Qty.

Wireless Hand-Held Remote

1

(3) AA batteries and equipment labels included

D.

PA122

178PA28A

Water Temperature Sensor

Freeze (Air Temperature) Sensor

• Monitors pool/spa water temperatures
• Connects to PE653 receiver to communicate water
temperature
• 1-year warranty
Model #
D. PA122

• Protects pool/spa equipment and plumbing
• Perfect for below-freezing outdoor environment
• Monitors outside air temperature
• 1-year warranty

Description

Qty.

Water Temperature Sensor

1

Needed to enable thermostat feature on the PE653RC

E.

Model #

Description

Qty.

E. 178PA28A

Freeze Sensor

1

Needed to enable freeze protection feature on the PE653RC

www.intermatic.com

115

Pool & Spa

Pool OR Spa

A.

B.

Pool & Spa Combo

PE20000RC Series Kits

60 Amp MultiWave Control System

C ont ro l You r
P ool AN D S pa C om bo
PE24065RC Kit Includes:
•P
 E20000 Load Center with
60 Amp Base
• PE653RC MultiWave Control System
• Water and Air Sensor
with Mounting Hardware
• P4043ME Actuator Controller
• (2) PE24VA Valve Actuators
• Equipment Labels

116

• For a single pool or spa or a pool/spa combo
• Load center with four position 60 Amp breaker base
• Two knockouts for GFCIs and switches
• Controls 5 circuits
• Full thermostat control
• Operates single, two, and variable-speed pumps
• 24-hour scheduling capability for all connected equipment
• Type 3R indoor/outdoor 0.048" steel load center
Model #

Application

A. PE20065RC

Pool or Spa

B. PE24065RC

Pool/Spa Combo

Actuator Control
—

—

P4043ME

2 (PE24VA)

Each kit also includes (3) AA batteries and a flathead screwdriver.

Ratings:

Valve Actuators

Load Center Rating: 60 A, 120/240 VAC or 120/208 VAC single phase
Control Supply: 120/240 VAC, 50/60 Hz, 5 W max.
Circuit 1: 20 A Resistive (17 FLA, 80 LRA) 120, 240 VAC 50/60 Hz.
Circuits 2-5: 15 A Resistive (10 FLA, 60 LRA) 120, 240 VAC 50/60 Hz.
Load Center Dimensions: 16 1⁄2" (41.9 cm) H x 10 7⁄8" (27.6 cm) W x 4 1⁄4" (10.8 cm) D
Knockouts:
	
Bottom: (2) 1.09" ø through holes, (6) combination 1⁄2" – 3⁄4", (3) combination 3⁄4" – 1"
Left: (2) combination 1⁄2" – 3⁄4"
Back: (1) combination 3⁄4" – 1"
Right: (1) 1 3⁄4" x 2 3⁄4" for mounting switches or GFCI
Warranty: 2 year

Pool & Spa

Pool OR Spa

Pool & Spa Combo

C.

D.

PE30000RC Series Kits

80 Amp MultiWave Control System
• For a single pool or spa or a pool/spa combo
• Load center with eight position 80 Amp breaker base
• Four knockouts for GFCIs and switches
• Controls 5 circuits
• Full thermostat control
•O
 perates single, two, and variable-speed pumps
 4-hour scheduling capability for all connected equipment
•2
• Type 3R indoor/outdoor 0.048" steel load center
Model #

Application

C. PE30065RC

Pool or Spa

D. PE34065RC

Pool and Spa Combo

Co n t r o l Yo ur
P o o l A ND S p a Co mb o
PE34065RC Kit Includes:
•P
 E30000 Load Center with
80 Amp Base

Actuator Control

Valve Actuators

—

—

P4043ME

2 (PE24VA)

Each kit also includes (3) AA batteries and a flathead screwdriver.

• PE653RC MultiWave Control System
• Water and Air Sensor
with Mounting Hardware
• P4043ME Actuator Controller
• (2) PE24VA Valve Actuators

Ratings:

Load Center Rating: 80 A, 120, 240 VAC or 120, 208 VAC single phase
Control Supply: 120, 240 VAC, 50/60 Hz., 5 W max.
Circuit 1: 20 A Resistive (17 FLA, 80 LRA) 120, 240 VAC 50/60 Hz.
Circuits 2-5: 15 A Resistive (10 FLA, 60 LRA) 120, 240 VAC 50/60 Hz.
Load Center Dimensions: 22" (55.9 cm) H x 14 3⁄4" (37.5 cm) W x 4 1⁄4" (10.8 cm) D
Knockouts:
	
Bottom: (2) 1.09"ø through holes, (6) combination 1⁄2" – 3⁄4,"
(2) combination 3⁄4", 1", 1 1⁄4", (4) 1⁄2"
Left: (2) combination 1⁄2" – 3⁄4"
Back: (4) combination 1⁄2" – 3⁄4", and (2) combination 3⁄4" – 1"
Right: (1) 1 3⁄4" x 2 3⁄4" for mounting switches or GFCI
Warranty: 2 year

www.intermatic.com

• Equipment Labels

117

Pool & Spa

P4043ME and PE140
Valve Actuator Controls

A.

• Easily snap into most existing Intermatic enclosures with
available mechanism support bracket
•	Controls up to three valve actuators
•	Switches heater thermostat HIGH/LOW
•	Remote control capabilities
Model #

Description

A. P4043ME

Mechanism Only

B. PE140

P4043ME with Type 3R Enclosure

Ratings:

Input Voltage: 120 or 240 VAC, 50/60 Hz.
Valve Actuator Supply: 24 VAC, 40 VA
Warranty: 1 year

B.

P4243ME

Valve/Pump Switch Mechanism
•
•
•
•
•

Controls up to 2 circuits associated with pool/spa combos
Snaps into most Intermatic enclosures
Automatic HIGH/LOW water temperature selector
Manual load control
Wireless remote and master controller connections
Model #

C. P4243ME
Ratings:

Description

Actuator Supply

Mechanism Only

(3) 24 VAC Actuators

Each Circuit:
Valve Actuator Supply: 24 VAC, 40 VA
17 A Resistive, 120-240 VAC, 50/60 Hz.
1.5 HP, 120 VAC, 50/60 Hz.
3 HP, 240 VAC, 50/60 Hz.
10 A Tungsten, 120 VAC, 50/60 Hz.
Warranty: 1 year

C.

118

Save up to 40%

Pool & Spa

NEW

In Monthly Utility Bills

P1403ME and PE103

TITLE

20

Electronic 1 or 2-Speed Pump Timer with
Seasonal Adjust

D.

COMPLIANT

•S
 aves up to 40% in monthly utility bills compared to
standard timers
• Meets most rebate incentives
• Full single and two-speed pump control
• Enables separate daily schedules
• Additional circuit for auxiliary equipment
• Easy-to-follow on-screen setup for programming
• Auto-Voltage adjust
• Automatically adjusts pump operation according to season
• Efficient low-speed operation for all seasons
• User-programmable high and low-speed events
• 100+ hour supercapacitor memory retention

NEW

Model # Description

Input Votage

Switch

D.

P1403ME

Mechanism Only

120, 240 VAC, 50/60 Hz

4-SPST

E.

PE103

P1403ME with Type 3R Enclosure 120, 240 VAC, 50/60 Hz

4-SPST

Ratings:

Power Consumption: 7 W max.
Contact Ratings (SPST) Each Circuit:
30 A Inductive and Resistive at 24 VAC, 120-277 VAC
16 FLA, 96 LRA at 120 VAC
17 FLA, 80 LRA at 240 VAC
20 A Resistive at 28 VDC
5 A Tungsten at 120-277 VAC
Clock Source Voltage: 120-277 VAC, 50/60 Hz.
Warranty: 1 year

E.

www.intermatic.com

119

Pool & Spa

P1353ME

TITLE

Digital 3-Circuit Time
Switch Mechanism

20

COMPLIANT

• Perfect upgrade for your T100 Series time switch
•	Three ON/OFF events per day per circuit
•	Seven pre-programmed modes
•	Memory backup
•	Freeze and heater protection
•	LCD readout
• Countdown and override features enable programs
to be overridden and automatically resumed without
requiring the user to reprogram the system
Model #
A. P1353ME

Input Voltage

Switch

120/240 VAC, 50/60 Hz

3-SPST

Rating:

Contacts:
17 A Resistive, 120/240 VAC, 50/60 Hz.
(20 FLA, 96 LRA), 120 VAC, 50/60 Hz.
(17 FLA, 80 LRA) 240 VAC, 50/60 Hz.
5 A Tungsten, 120/240 VAC, 50/60 Hz.
Warranty: 1 year
For replacement parts see page 151

A.

Pr e - Pr og r a mme d Mode s
Mode 1 – (Aux1, Aux2, Aux3)

Mode 5 – (Pump L1, Pump L2, Aux3)

• All 3 switches control auxiliary devices

• 1st and 2nd switch controls a 240 VAC pump, where
L1 and L2 are disconnected when the pump is OFF

Mode 2 – (Pump High, Pump Low, Aux3)
• 1st and 2nd switch controls a two-speed pump
• 3rd switch controls an auxiliary device

Mode 6 – (Aux1, Aux2, Aux3)
 Heater green mode

• Two-speed pump timing and protection

• Identical to Mode 1, with capability to run a heater when the
filter pump is manually turned ON only

Mode 3 – (Pump, Aux2, Cleaner Pump)
• 1st switch controls a single-speed pump
• 2nd switch controls an auxiliary device
• 3rd switch controls a booster/cleaner pump

• This mode is ideal for connecting Circuit 1 to a circulation pump
in a spa. NOTE: When spa is not in use, the clock does not turn the heater
ON. When spa is in use, the heater can be activated by manually switching
Circuit 1 ON.

• Filter/cleaner pump timing and protection

Mode 7 – (Pump High, Pump Low, Common)
Break both lines

Mode 4 – (Pump High, Pump Low, Cleaner Pump)

• Identical to Mode 2, with the capability to break both hot lines
of a 240 VAC two-speed pump connection

• 1st and 2nd switch controls a two-speed pump
• 3rd switch controls a booster/cleaner pump
•T
 wo-speed and filter/cleaner pump
timing and protection

120

• 3rd switch controls any auxiliary device

• 1st and 2nd circuits connect to High and Low lines of a
two-speed pump and 3rd circuit connects to the
common hot leg
• Two-speed pump timing and protection

Pool & Spa

B.

Freeze Probe included

C.

D.

Freeze Probe included

E.

PE100 Series

TITLE

Digital 3-Circuit Time Switch in Enclosure
•
•
•
•
•
•
•

20

COMPLIANT

Controls single and two-speed pumps and cleaner/booster pumps
Three ON/OFF events per circuit per day
Seven pre-programmed modes
Freeze and heater protection
LCD readout
Multi-voltage input and output
C
 ountdown and override features enable programs to be overridden and automatically
resumed without requiring the user to reprogram the system
Model #

Rating:

Input Voltage: 120/240 VAC, 50/60 Hz.
17 A Resistive, 120/240 VAC, 50/60 Hz.
(20 FLA, 96 LRA), 120 VAC, 50/60 Hz.
(17 FLA, 80 LRA), 240 VAC, 50/60 Hz.
5 A Tungsten, 120/240 VAC, 50/60 Hz.
Warranty: 1 year

Input Voltage

Accessory

Switch

Enclosure

B. PE153

120, 240 VAC, 50/60 Hz

—

3-SPST

Type 3R Steel

C. PE153F

120, 240 VAC, 50/60 Hz

Freeze Probe

3-SPST

Type 3R Steel

D. PE153P

120, 240 VAC, 50/60 Hz

—

3-SPST

Type 3R Plastic

E. PE153PF

120, 240 VAC, 50/60 Hz

Freeze Probe

3-SPST

Type 3R Plastic

For replacement parts and accessories, see page 154
For enclosures see page 146

www.intermatic.com

121

Pool & Spa

PE10000 Series

Pool/Spa Control System with
Type 3R Power Center
• Includes P1353ME 3-circuit mechanism and power center
• P1353ME controls single and two-speed filter pumps,
cleaner/booster pumps, and pool/spa landscape lighting
Model #
A. PE10000

A.

PE15300
B. PE15300F

Mechanism

Accessory

Power Center only

—

P1353ME

—

P1353ME

Ratings:

Freeze Probe

P1353ME Switch Ratings Each Circuit (SPST):
Input Voltage: 120/240, VAC 50/60 Hz.
Contacts:
17 A Resistive 120/240 VAC,
5 A Tungsten 120/240 VAC,
17 FLA, 80 LRA 120/240 VAC
Auxiliary Switch: 2 A, 24 VAC
Power Center Dimensions: 16 ½" (41.9 cm) H x
10 7⁄8" (27.6 cm) W x 4 ¼" (10.8 cm) D

B.

Switch
—
3-SPST
3-SPST

Knockouts:
	Bottom: (1) 1.09" ø through hole,
(3) 1⁄2 ", (7) 1⁄2 "– 3⁄4", (2) 3⁄4 " – 1"
Left: Two ½ " – ¾"
Back: (1) ½ " – ¾", (1) ¾ " – 1"
Right: (1) 1 3⁄4" x 2 3⁄4"
Warranty: 1 year

Freeze Probe

PE20000 Series

60 Amp Pool/Spa Control System with
Type 3R Load Center
• 60 Amp 4-position breaker base
• Includes P1353ME 3-circuit mechanism and load center
• P1353ME controls single and two-speed filter pumps,
cleaner/booster pumps, and pool/spa landscape lighting

C.
C.
D.

Model #

Mechanism

PE20000

Load Center only

Accessory
—

PE25300

P1353ME

—

PE25300F

P1353ME

Freeze Probe

Switch
—
3-SPST
3-SPST

Ratings:

P1353ME Switch Ratings For Each Circuit (SPST): Knockouts:
	Bottom: (1) 1.09"ø through hole,
Input Voltage: 120/240 VAC, 50/60 Hz.
(6) ½" – ¾", 3 ¾" – 1"
Contacts:
Left: (2) ½" – ¾"
17 A Resistive 120/240 VAC,
Back: (1) ¾" – 1"
5 A Tungsten 120/240 VAC,
Right: (1) 1 ¾" x 2 ¾" for mounting
17 FLA, 80 LRA 120/240 VAC
switches or GFCI
Auxiliary Switch: 2 A, 24 VAC
Warranty: 1 year
Load Center Dimensions: 14 ¾" (37.5 cm) H x
14 ¾" (37.5 cm) W x 4 ¼" (10.8 cm) D

For further information on P1353ME mechanism, see page 120.
Wiring devices may be installed in the power and load centers
(order (4) 21T156A standoffs for mounting). See page 154.
D.
122

For accessories, see page 153.
Freeze Probe

Pool & Spa

PE30000 Series

80 Amp Pool/Spa Control System with
Type 3R Load Center
• 80 Amp 8-position breaker base
• Includes P1353ME 3-circuit mechanism and load center
• P1353ME controls single and two-speed filter pumps, cleaner/
booster pumps, and pool/spa landscape lighting
Model #
E. PE30000

F.

Mechanism

Switch

Transformer

Load Center only

—

—

PE30000T3

Load Center only

—

300W

PE35300

P1353ME

3-SPST

—

Ratings:

P1353ME Switch Ratings Each Circuit (SPST):
Input Voltage: 120/240 VAC, 50/60 Hz.
Contacts:
17 A Resistive 120/240 VAC,
5 A Tungsten 120/240 VAC,
17 FLA, 80 LRA 120/240 VAC
Auxiliary Switch: 2 A, 24 VAC
Load Center Dimensions: 22" (55.9 cm) H x
14 ¾" (37.5 cm) W x 4 ¼" (10.8 cm) D

E.

Knockouts:
	Bottom: (1) 1.09"ø through hole,
(6) ½" – ¾", (2) ¾"– 1"– 1 ¼", (4) ½"
Left: (2) ½" – ¾"
Back: (4) ½" – ¾", (2) ¾" – 1"
Right: (1) 1 3⁄4" x 2 3⁄4" for mounting
switches or GFCI
Warranty: 1 year

F.

PE40000 Series

125 Amp Pool/Spa Control System with
Type 3R Load Center
• 125 Amp 8-position breaker base
• Includes P1353ME 3-circuit mechanism and load center
• P1353ME controls single and two-speed filter pumps,
cleaner/booster pumps, and pool/spa landscape lighting
Model #

Mechanism

G.

PE40000

Load Center only

Switch

H.

PE45300

P1353ME

—
3-SPST

G.

Ratings:

P1353ME Switch Ratings Each Circuit (SPST):
Input Voltage: 120/240 VAC, 50/60 Hz.
Contacts:
17 A Resistive 120/240 VAC,
5 A Tungsten 120/240 VAC,
17 FLA, 80 LRA 120/240 VAC
Auxiliary Switch: 2 A, 24 VAC
Load Center Dimensions: 26" (66.3 cm) H x
18" (45.9 cm) W x 5 ½" (14 cm) D

Knockouts:
	Bottom: (1) 1.09"ø through hole,
(13) 1⁄2" – 3⁄4", (2) ¾"– 1"– 1 ¼",
Left: (1) ½" – ¾", (2) ¾"– 1"
Back: (4) ½" – ¾", (2) ¾"– 1"
Right: (1) 1 3⁄4" x 2 3⁄4" for mounting
switches or GFCI
Warranty: 1 year

For further information on P1353ME mechanism, see page 120.
Wiring devices may be installed in this load center
(order (4) 21T156A standoffs for mounting). See page 154.
H.
www.intermatic.com

123

Pool & Spa

T100M Series

24-Hour Mechanical Time Switches

A.

• Highest motor load ratings in the industry
• 12 ON/OFF operations per day
• ON/OFF trippers included
• Can be installed in most Intermatic enclosures
• Available with pool heater protection
Without Pool Heater Protection
A.

Model #

Switch

Input Voltage

T101M

SPST

120 VAC, 60Hz

T103M

DPST

120 VAC, 60Hz

T104M

DPST

208-277 VAC, 60Hz

T106M

SPDT

208-277 VAC, 60Hz

With Pool Heater Protection
B.

T104M201

DPST

208-277 VAC, 60Hz

Rating:
Switch Rating:
• 40 A Resistive each pole, 120-480 VAC
• 40 A Tungsten, Inductive or 1000 VA Pilot Duty each pole 120-277 VAC
• 2 HP (24 FLA) 120 VAC
• 5 HP (28 FLA) 240 VAC
Heater Control Circuit: 10 A, 240 VAC max.
Operating Temperature Range: -40°F to 130°F (-40°C to 54°C)
Warranty: 1 year
For parts, trippers and accessories, see page 153

B.

124

Pool & Spa
C.

T100 Series

24-Hour Mechanical Time Switches in Enclosure
• Highest motor load ratings in the industry
• 12 ON/OFF operations per day
• ON/OFF trippers included
• Available with pool heater protection
Without Pool Heater Protection
Model #

Enclosure

Switch

Input Voltage

T101P3

Type 3R Plastic

SPST

120 VAC, 60 Hz

C. T104P3

Type 3R Plastic

DPST

208-277 VAC, 60 Hz

T106P3

Type 3R Plastic

1 N.O./1 N.C.

208-277 VAC, 60 Hz

D. T101R3

Type 3R Steel

SPST

120 VAC, 60 Hz

T104R3

Type 3R Steel

DPST

208-277 VAC, 60 Hz

With Pool Heater Protection

D.

Model #

Enclosure

Switch

Input Voltage

T101P201

Type 3R Plastic

SPST

120 VAC, 60 Hz

T104P201

Type 3R Plastic

DPST

208-277 VAC, 60 Hz

E. T101R201

Type 3R Steel

SPST

120 VAC, 60 Hz

T104R201

Type 3R Steel

DPST

208-277 VAC, 60 Hz

Rating:

Switch Rating:
• 40 A Resistive each pole, 120-480 VAC
• 4 0 A Tungsten, Inductive or 1000 VA Pilot Duty each pole 120-277 VAC
• 2 HP (24 FLA) 120 VAC
• 5 HP (28 FLA) 240 VAC
Heater Control Circuit: 10 A, 240 VAC max.
Operating Temperature Range: -40°F to 130°F (-40°C to 54°C)
Warranty: 1 year

For replacement parts, trippers and accessories, see page 153.
For additional enclosures, see page 146.

E.
www.intermatic.com

125

Pool & Spa
A.

B.

C.

T10000R Series

Control System with Type 3R Power Centers
• Available with one or two heavy-duty time switch mechanisms
• Accepts any combination of PF1000M, P1403ME, P1353ME,
P4043ME, P4243ME, T100M, or RC2000M Series mechanisms
• GFCI and switch mounting capabilities
Mechanism(s)

Switch

Mechanism Supply Voltage

A. T10000R

Model #

Power Center only

—

—

B. T10004R

(1) T104M

DPST

240 VAC, 60 Hz

T10006R

(1) T106M

SPDT

240 VAC, 60 Hz

C. T10101R

(2) T101M

SPST/SPST

120/120 VAC, 60 Hz

T10404R

(2) T104M

DPST/DPST

240/240 VAC, 60 Hz

T10604R

T106M & T104M

SPDT/DPST

240/240 VAC, 60 Hz

T12404R*

T104M201 & T104M

DPST/DPST

240/240 VAC, 60 Hz

*The heater protection switch is closed when the time switch contacts are open to allow remote
operation of heater. A flow or pressure switch must always be part of heater control circuit.

Ratings:

Switch Rating:
• 30 A Resistive/Inductive, Tungsten or 1000 VA Pilot Duty
each pole 120, 208, 240 VAC
• 2 HP (24 FLA), 120 VAC
• 5 HP (28 FLA), 240 VAC
Operating Temperature Range:
-40°F to 130°F (-40°C to 54°C)
Power Center Dimensions:
12" (30.5 cm) H x 12" (30.5 cm) W x 4 ¼" (10.8 cm) D
Knockouts:
Bottom: (5) combination ½"– ¾"
and (2) combination ¾" – 1"
Left: (1) combination ½" – ¾"
Back: (1) combination ¾" – 1," (1) ½"– ¾"
Right: (1) 1 ¾" x 2 3⁄4" for mounting switches or GFCI
Warranty: 1 year

For replacement parts, trippers and accessories, see page 153.
See page 125 for further information on mechanism.
Wiring devices may be installed in this power center (order (4) 21T156A standoffs for mounting). See page 154.

126

Pool & Spa

D.

E.

T20000R Series

60 Amp Pool/Spa Control System with Type 3R Load Center
• Comes with 4/8 position breaker base, equipment grounding bar, and
mechanical time switch mechanism
• Accepts PF1000M, P1403ME, P1353ME, P4043ME, P4243ME,
T100M, or RC2000M Series mechanisms
• Accepts many interchangeable-type breakers
• GFCI and switch mounting capabilities
Ratings:

Load Center Rating: 60 A, 120, 240 VAC or
120, 208 VAC 60 Hz., Single Phase, 60 Hz.
Switch Rating:
• 3 0 A Resistive/Inductive, Tungsten or
1000 VA Pilot Duty each pole 120, 208, 240 VAC
• 2 HP (24 FLA), 120 VAC
• 5 HP (28 FLA), 240 VAC
Operating Temperature Range: -40°F to 130°F (-40°C to 54°C)
Load Center Dimensions:
16 3 ⁄4" (42.6 cm) H x 8 7 ⁄8" (22.5 cm) W x 4 3 ⁄8" (11.1 cm) D
Knockouts:
Bottom: (5) combination ½"– ¾" and (3) combination ¾" – 1"
Left: (1) combination ½" – ¾"
Back: (1) combination ¾" – 1"
Right: (1) 1 ¾" x 2 3⁄4" for mounting switches or GFCI
Warranty: 1 year

Mechanism

Switch

Mechanism Supply Voltage

D. T21000R

Model #

Load Center Only

—

—

E. T21001R

T101M

SPST

120 VAC, 60 Hz

T21004R

T104M

DPST

240 VAC, 60 Hz

For replacement parts, trippers and accessories, see page 153.
See page 125 for further information on mechanism.
Wiring devices may be installed in this load center
(order (4) 21T156A standoffs for mounting). See page 154.

www.intermatic.com

127

Pool & Spa

All-In-One

A.

C.

B.

T30000R Series

100 Amp Pool/Spa Control System with Type 3R Load Center
• Comes with an 8/16 circuit breaker base, equipment grounding bar, and a mechanical time switch(es)
• Reduces installation costs
• Eliminates the need for additional service panels
• Accepts any combination of PF1000M Series, P1403ME, P1353ME, P4043ME, P4243ME,
T100M Series, or RC2000M Series mechanisms
• Fully compatible with all electrical requirements for pool/spa installations
• GFCI and switch mounting capabilities
Model #

Mechanism(s)

Switch

Mechanism Supply Voltage

A.

T30000R5

Load Center only

—

B.

T30004R

(1) T104M

DPST

240 VAC, 60Hz

C.

T30401R

T104M & T101M

DPST/SPST

240/120 VAC, 60Hz

T30404R

(2) T104M

DPST/DPST

240/240 VAC, 60Hz

T30604R

T106M & T104M

SPDT/DPST

240/240 VAC, 60Hz

T32404R*

T104M201 & T104M

DPST/DPST

240/240 VAC, 60Hz

—

*The heater protection switch is closed when the time switch contacts are open to allow remote
operation of heater. A flow or pressure switch must always be part of heater control circuit.
See page 124 for further information on mechanisms.
Wiring devices may be installed in this load center
(order (4) 21T156A standoffs for mounting). See page 154.
For replacement parts, trippers and accessories see page 153.

128

Ratings:

Load Center Rating: 100 A, 120, 240 VAC
or 120, 208 VAC single phase, 60 Hz
Switch Rating:
• 30 A Resistive/Inductive, Tungsten or 1000 VA Pilot Duty
each pole 120, 208, 240 VAC
• 2 HP (24 FLA), 120 VAC
• 5 HP (28 FLA), 240 VAC
Operating Temperature Range: -40°F to 130°F (-40°C to 54°C)
Load Center Dimensions: 16 ½" (41.9 cm) H x
10 7 ⁄8" (27.6 cm) W x 4 ½" (11.43 cm) D
Knockouts:
Bottom: (4) ½"– ¾", (3) ½", (2) ¾" – 1"
Left: (1) ¾" – 1"
Back: (5) ½"– ¾"
Right: (1) 1 ¾" x 2 3⁄4" for mounting switches or GFCI
Warranty: 1 year

D.

E.

F.

G.

Pool & Spa

Electrical Load Center

T40000R Series

125 Amp Pool/Spa Control System with Type 3R Load Center
• Comes with an 8/16 circuit breaker base, equipment grounding bar, and mechanical time switch(es)
• Reduces installation costs
• All-in-one electrical load center eliminates the need for additional service panels
• Accepts any combination of PF1000M Series, P1403ME, P1353ME, P4043ME, P4243ME,
T100M Series, or RC2000M Series mechanisms
• Fully compatible with all electrical requirements for pool/spa installations
• GFCI and switch mounting capabilities
Model #

Ratings:

Load Center Rating: 125 A max. 120, 240 VAC or 120, 208 VAC
single phase, 60 Hz.
Switch Rating:
• 30 A Resistive/Inductive, Tungsten or 1000 VA Pilot Duty
each pole 120, 208, 240 VAC
• 2 HP (24 FLA), 120 VAC
• 5 HP (28 FLA), 240 VAC
Operating Temperature Range: -40°F to 130°F (-40°C to 54°C)
Load Center Dimensions: 20 ¾" (52.7 cm) H x 12 ¾" (32.4 cm) W x
4 ½" (11.43 cm) D
Knockouts:
Bottom: (5) ½" – ¾", (4) ½", (2) ¾" – 1", 1 1⁄4"
Left: (1) ½" – ¾"
Back: (4) ½" – ¾", (2) ¾" – 1"
Right: (1) 1 ¾" x 2 3⁄4" for mounting switches or GFCI
Warranty: 1 year

D. T40000R

Mechanism(s)
Load Center

Switch

Mechanism Supply Voltage

—

—

E.

T40004R

(1) T104M

DPST

240 VAC, 60 Hz

F.

T40404R

(2) T104M

DPST

240/240 VAC, 60 Hz

G. T40000R4

Load Center with GCFI

—

—

See page 124 for further information on mechanisms.
Wiring devices may be installed in this load center
(order (4) 21T156A standoffs for mounting). See page 154.
For replacement parts, trippers and accessories see page 153.

www.intermatic.com

129

Pool & Spa

A.

B.

C.

D.

PX50, PX100, PX300, & PX600 Series
Safety Transformers

• Supply 12 volts to pool/spa lights, submersible fixtures, and outdoor garden lights
• Mounting brackets on the top and bottom
3R Beige Steel Enclosure
A.

B.

Rating:

Model #

Input Voltage

Output Voltage

Watts

PX50

120 VAC, ½ Amp

12 or 13 VAC

50

PX100

120 VAC, 1 Amp

12 or 13 VAC

100

PX300

120 VAC, 3 Amp

12, 13, or 14 VAC

300

PX600

120 VAC, 6 Amp

12, 13, or 14 VAC

600

3R Stainless Steel Enclosure
C.

D.

130

Model #

Input Voltage

Output Voltage

Watts

PX50S

120 VAC, ½ Amp

12 or 13 VAC

50

PX100S

120 VAC, 1 Amp

12 or 13 VAC

100

PX300S

120 VAC, 3 Amp

12, 13, or 14 VAC

300

PX600S

120 VAC, 6 Amp

12, 13, or 14 VAC

600

PX50/S, PX100/S, PX300/S
Size: 7 ¼" (18.4 cm) H x 5 ¼" (13.3 cm) W x 4 ½" (11.4 cm) D
Knockouts:
Bottom: (4) combination ½" – ¾"
Left: (2) combination ½" – ¾"
Back: (2) combination ½" – ¾"
Right: (2) combination ½" – ¾"
PX600/S
Size: 10" (25.4 cm) H x 10" (25.4 cm) W x 5" (12.7 cm) D
Knockouts:
Bottom: (2) combination ½" – ¾," (4) combination ¾" – 1"
Left: (2) combination ½" – ¾"
Back: (2) combination ½" – ¾"
Right: (2) combination ½" – ¾"

Pool & Spa

E.

F.

G.

T10000RT, T40000RT Series

Control System with Transformer and Power or Load Center
• All-in-one control power for pool/spa installation
• Easy to wire
• Can house additional Intermatic mechanisms and components
• Heavy-duty Type 3R steel Indoor/Outdoor power and load centers
Transformer
E.
F.

Model #

Description

T10004RT1

Power Center with T104M

240 VAC

T10004RT3

Power Center with T104M

240 VAC

T40003RT3

Load Center with T103M

T40004RT1

Load Center with T104M

T40004RT3

Load Center with T104M

G. T40000RT3

Mechanism Supply Voltage

Input Voltage, 60 Hz

Output Voltage

100

120 VAC, 1 Amp

12 or 13 VAC

300

120 VAC, 3 Amp

12, 13, or 14 VAC

120 VAC

300

120 VAC, 3 Amp

12, 13, or 14 VAC

240 VAC

100

120 VAC, 1 Amp

12 or 13 VAC

240 VAC

300

120 VAC, 3 Amp

12, 13, or 14 VAC

300

120 VAC, 3 Amp

12, 13, or 14 VAC

Load Center Only

—

Ratings:

T10000RT Series:
Power Center Rating: 62 A per leg, 168 A max., 120, 240 VAC or
120, 208 VAC single phase, 60 Hz.
Power Center Dimensions: 12" (30.5 cm) H x 12" (30.5 cm) W x
4 ¼" (10.8 cm) D
T40000RT Series:
Load Center Rating: 100 A, 120, 240 VAC or 120, 208 VAC
single phase, 60 Hz.
Load Center Dimensions:
20 ¾" (52.7 cm) H x 12 ¾" (32.4 cm) W x 4 ¼" (10.8 cm) D
Switch Rating:
• 30 A Resistive/Inductive, Tungsten or 1000 VA Pilot Duty
each pole 120, 208, 240 VAC
• 2 HP (24 FLA), 120 VAC
• 5 HP (28 FLA), 240 VAC
Operating Temperature Range: -40°F to 130°F (-40°C to 54°C)
Warranty: 1 year

Watts

D i d Yo u K n o w ?
Many transformers that power LED’s do not comply with
the NEC Code 680.23 requirements. The code states
transformers used for the supply of underwater luminaries
must be listed and marked for pool and spa transformer
use. Listed pool and spa transformers must comply with
UL-379 and CSA TILB44A standards.
Non-compliant transformers increase the potential for
severe injury and electrocution and raise liability concerns
for contractors and installers.

See page 124 for further information on mechanisms.
Wiring devices may be installed in this power or load center
(order (4) 21T156A standoffs for mounting). See page 154.
For replacement parts, trippers and accessories see page 153.

www.intermatic.com

131

Pool & Spa
A.

B.

C.

D.

Thermostat without Mechanism
A.

PF1100 Series

Single-Circuit Freeze Protection Controls
• Protect pool/spa equipment against freeze damage
• Turn pump and heater ON when outdoor temperature drops
below user-adjustable setpoint on thermostat

B.

Model #

Enclosure

Input Voltage

HP

PF1102M

Thermostat only

240 VAC

3

PF1103M*

Thermostat only

120/240 VAC

1.5/3

PF1102

Type 3R steel

240 VAC

3

PF1103*

Type 3R steel

120/240 VAC

1.5/3

Thermostat with Mechanism
Model #

Rating:

Thermostat Range: 33°F to 42°F (0.6°C to 5.5°C)
with 5°F differential
Warranty: 1 year

C. PF1102MT

PF1103MT*
D. PF1102T

PF1103T*

Enclosure

Input Voltage

HP

Mechanism only

240 VAC

3

Mechanism only

120/240 VAC

1.5/3

Type 3R steel

240 VAC

3

Type 3R steel

120/240 VAC

1.5/3

*Neutral must be installed
For replacement parts, trippers and accessories, see page 153.

132

Pool & Spa

The Ultimate
Ice Breaker

E.

F.

Rating:

PF1112T, PF1202T
Power Center Rating: 92 A per leg, 168 A max.
120/ 240 VAC or 120/240 VAC single phase, 60 Hz.
Power Center Dimensions: 12" (30.5 cm) H x
12" (30.5 cm) W x 4 ¼" (10.8 cm) D
PF1222TB1
Load Center Rating: 85 A max., 120, 240 VAC or
120, 208 VAC single phase, 60 Hz.
Load Center Dimensions: 20 ¾" (52.7 cm) H x
12 ¾" (32.4 cm) W x 4 ¼" (10.8 cm) D
Thermostat Range: 33°F to 42°F (0.5°C to 5.5°C)
with 5°F differential
Switch Rating:
• 30 A Resistive/Inductive, Tungsten or
1000 VA Pilot Duty each pole 120, 208, 240 VAC
• 2 HP (24 FLA), 120 VAC
• 5 HP (28 FLA), 240 VAC
Warranty: 1 year

G.

PF1100 and PF1200 Series

Control System with Freeze Protection and
Power or Load Center
• For pools/spas requiring one or two time switches
• Protects pool/spa equipment against freeze damage
• GFCI and switch mounting capabilities
• Turns pump and heater ON when outdoor temperature drops below
user-adjustable setpoint on thermostat
• Heavy-duty Type 3R steel Indoor/Outdoor power and load centers
Model #

Description

Input Voltage

HP Heater Protection

E. PF1112T

Power Center with (1) Time Switch

240 VAC

3

No

F. PF1202T

Power Center with (2) Time Switches

240 VAC

3

No

G. PF1222TB1*

Load Center with (2) Time Switches

240 VAC

3

Yes

*4/8 Breaker base and heater protection

For replacement parts, trippers and accessories see page 153
Wiring devices may be installed in this power or load center
(order (4) 21T156A standoffs for mounting). See page 154.

www.intermatic.com

133

Pool & Spa

RC2103S

Air Actuated Remote Control
• Safely controls loads without electricity at a pool/spa
• Type 3R plastic Indoor/Outdoor enclosure
• Controls one piece of equipment with one air button
(button not included)
Model #
A. RC2103S

Switch

Range

SPST

100 ft.

Rating:

Input Voltage: 120 VAC, (Line and Neutral) or 240 VAC, (Line 1, and Line 2 and Neutral) 60 Hz.
Switch Rating: 20 A Resistive 120, 240 VAC, 1 HP 120 VAC, 2 HP 240 VAC
Dimensions 4 1⁄8" (10.5 cm) H x 4 1⁄8" (10.5 cm) W x 3 3⁄8" (8.6 cm) D
Warranty: 1 year

A.

RC Series

Air Switches and Accessories
B.

• For air control equipment
• Replaces existing buttons

C.

Model #

Description

Range

B.

RC4G

Air button for gunite spas

100 ft.

—

C.

RC6F

Air button - universal

150 ft.

—

D.

RC117

Air tubing

—

75 ft.

RC150

Air tubing

—

500 ft.

RC122B

Air tubing and RC4G

—

25 ft.

RC127B

Air tubing and RC4G

—

75 ft.

RC510

(10) Air tubing coupler

—

—

E.
D.

F.

E.

F.
134

Length

Pool & Spa

RC2000 Series

Multi-Function Air Switches with 24-Hour Timer
• Remote control for one or two separate loads
• Multiple ON/OFF settings per day
• Flexible airhose enables operation up to 75 feet
• Type 3R plastic Indoor/Outdoor enclosure
Model #
G. RC2123PT

RC2343PT

Description

Switch

Input Voltage

Timer with ON/OFF or
HIGH/LOW

SPDT

120/240 VAC, 60 HZ

2-circuit timer
with sequential operations

4-function

120/240 VAC, 60 Hz

Rating:

Switch Rating: 20 A Resistive, 120, 240 VAC, 1 HP, 120 VAC, 2 HP, 240 VAC, each circuit
Enclosure Dimensions: 9 3⁄8" (23.82 cm) H x 5 1⁄2" (13.97 cm) W x 3 3⁄4" (9.53 cm) D
Warranty: 1 year

G.

RC2100 Series

Air Switch Control System
• Controls pool/spa combos
• Heater control
• Override timer for spa mode
• (2) PE24VA 24-volt valve actuators
• Heavy-duty Type 3R steel Indoor/Outdoor load center
Model #
H. RC2163BE

RC2163BFE

Remote Command

Input Voltage

1-Air Button

120/240 VAC

Any SPST switch*

120/240 VAC

*Sold separately

Rating:

Load Center Rating: 100 A, 120, 240 VAC or 120, 208 VAC
single phase, 60 Hz.
Filter Pump:
Single Speed Only: 1.5 HP - 120 VAC, 3 HP - 240 VAC
Single or Two Speed: 1 HP - 120 VAC, 2 HP - 240 VAC
Breaker Spaces: 8/16
Number of Actuator Connections: 3
Load Center Dimensions:
16 ½" (41.9 cm) H x 10 7 ⁄8" (27.6 cm) W x 4 ¼" (10.8 cm) D
Warranty: 1 year
For replacement parts, trippers and accessories, see page 153.

H.
www.intermatic.com

135

Pool & Spa
A.

B.

PB300 Series

Electronic Panel Mount Timers
•
•
•
•
•

24-Hour and 7-Day models
Perfect for applications where equipment needs to be cycled ON/OFF up to 8 times per day
Select feature enables timers to be continuously ON, OFF, or in AUTO mode
Rugged construction
3-year service life replaceable lithium battery
24-Hour

A.

Model #

Input Voltage

Switch

Amps

HP

PB313E

120 VAC, 50/60 Hz

SPDT

16

1

PB313EK*

120 VAC, 50/60 Hz

SPDT

16

1

PB314E

240 VAC, 50/60 Hz

SPDT

16

1

PB314EK*

240 VAC, 50/60 Hz

SPDT

16

1

FLA

⁄2

8

⁄2

8

⁄2

8

⁄2

8

7-Day
B.

Model #

Input Voltage

Switch

Amps

HP

FLA

PB373E**

120 VAC, 50/60 Hz

SPST

20

1

16

PB374E**

240 VAC, 50/60 Hz

SPST

20

2

12

*EK models are replacement kits
**Output voltage is same as supply

Replacing an existing
PB Series Timer?
Be s u re to o rder an EK model replacement kit!

136

Rating:

Enclosure: Beige electrical grade plastic
Dimensions: 2 3⁄8" (6 cm) H x 2 3⁄8" (6 cm) W 1 1⁄18" (28 cm) D
Warranty: 1 year

Pool & Spa

Up To 8 ON/OFF
Times per Day

D.

C.

P1000 and P7000 Series

24-Hour/7-Day Electronic Time Switch Mechanisms
•
•
•
•
•
•
•
•

Perfect for applications that turn equipment ON/OFF up to 8 times per day
To-the-minute programming accuracy
Dual voltage input (3-wire)
Safety door prevents unwanted entry into wiring compartment
Timer override
Select feature enables timers to turn ON/OFF in AUTO mode
24-Hour and 7-Day models
3-year service life replaceable lithium battery
Model #

Description

Switch

C.

P7103ME*

7-Day Mechanism Only

DPST

D.

P1103FE

24-Hour with Type 3R Plastic Enclosure

DPST

*Standard mechanism fits in all standard Intermatic enclosures and power and
load centers.

Rating:
Clock Supply Voltage: 120 VAC, 50/60 Hz.
Switch Rating:
20 A Resistive, 120-240 VAC
10 A Tungsten, 120 VAC
1.5 HP, 120 VAC, 3 HP, 240 VAC 50/60 Hz.
Warranty: 1 year

For replacement parts, trippers and accessories, see page 153.
For additional enclosures see page 146.

www.intermatic.com

137

Pool & Spa

A.

B.

C.

D.

PB800 and PB900 Series
Mechanical Panel Mount Timers

• Automated control for pumps, cleaners, and other types of loads
• 3 different mounting methods
• Quick connect terminals for easy installation
Model #

Switch Dial

Input Voltage

A. PB873MKZ

SPST

7-Day

120 VAC, 60 Hz

56

No

PB913N

SPST

24-Hour

120 VAC, 60 Hz

48

No

B. PB914N

SPST

24-Hour

208-277 VAC, 60 Hz

48

No

PB913N66

SPST

24-Hour

120 VAC, 60 Hz

48

Yes

C. PB914N66

SPST

24-Hour

208-277 VAC, 60 Hz

48

Yes

PB913N84

SPST

24-Hour

120 VAC, 60 Hz

4

Yes

D. PB914N84

SPST

24-Hour

208-277 VAC, 60 Hz

4

Yes

For replacement parts, trippers and accessories, see page 153.

138

No. of Trippers Manual Override

Rating:

Switch Rating:
20 A Resistive, 120-277 VAC
1250 W Tungsten 125 VAC
1 HP (16 FLA), 120 VAC
2 HP (12 FLA), 240 VAC
360 VA Pilot Duty, 120-240 VAC
Timing Cycle: 24-Hour – minimum ON time 1 hour,
maximum ON time 23 hours, 30-minute intervals
7-Day – minimum ON time 6 hours, maximum ON time
162 hours, 3-hour intervals
Quick Connect Terminals: (4) ¼" male (2) for load and
(2) for independent clock motor
Dimensions : 3 1⁄3" (84.8 cm) H x 2 13⁄16" (17.4 cm) W x
1 61⁄64" (49.6 cm) D
Warranty: 1 year

Pool & Spa

E.

F.

G.

P1100 Series

Portable Outdoor Timers
Ratings:

• Control filter pumps
• Turn outdoor decorations, engine block heaters, and other
appliances ON/OFF
Model #

Description

Plug & Receptacle

Cord Length

E. P1101

24-Hour timer

5-15

22"

P1121

24-Hour timer

5-15

13"

Heavy-duty 24-Hour timer
with twist-lock plug and receptacle

5L-20

22"

F.

G. P1131

Enclosure: Outdoor grade plastic Dimensions: 5" (12.7 cm) H
x 5 ½" (13.97 cm) W x 3 ¾" (9.52 cm) D
Cord: 3 wire, outdoor grade with grounded plug
Timer: 24-Hour with 23 ½ hour maximum ON time. Two ON,
two OFF trippers standard. Accepts up to 12 sets of trippers.
Switch Rating:
P1101 and P1121: 15 A (1800 W), Resistive or Tungsten,
1 HP Air Conditioner, (15 FLA, 90 LRA), Motor Load
P1131: 20 A Resistive, 1 HP, (15 FLA, 90 LRA) Motor Load
Warranty: 1 year

For replacement parts, trippers and accessories, see page 153.

P1200 Series

Two-Circuit Portable
Outdoor Timers
• Incorporate a plug-in for a timed circuit
and a plug-in for a live circuit
• Built-in GFCI protected circuits and
three-prong grounded plug for time
switch supply
• Great for above ground pool pumps,
lights, or fountains
• Type 3R plastic Indoor/Outdoor
enclosure
Photo Control
Model #

Photo Control

Plug & Receptacle

H. P1251P

Yes

5-15

J. P1261P

No

5-15

For replacement parts, trippers and accessories, see page 153.

www.intermatic.com

H.

J.
Ratings:

Timer: 24-Hour with 23 ½ hour maximum ON time.
Two ON, two OFF trippers standard.
Accepts up to 12 sets of trippers.
Switch Rating:
15 A (1800 W), Resistive or Tungsten, 1 HP (15 FLA, 90 LRA)
120 VAC Motor Load
Enclosure Dimensions: 9 3⁄8" H x 5 1⁄2" W x 3 3⁄4" D
Cord: 3 wire, outdoor grade, 24" with grounded plug
Warranty: 1 year

139

Pool & Spa

A.

B.

RC600 Series

Outdoor Radio Receivers
• Respond to handheld transmitter signals
• For indoor/outdoor use
• Handle a variety of switching applications
• Enable connected loads to be turned ON/OFF remotely

A.

B.

Model # Description

Switch Rating

Motor Load

RC613

Receiver with manual
ON/OFF button, 6" leads

15 Amp Resistive
10 Amp (1200W) Tungsten

1 HP, 120 VAC

RC613L

Receiver with manual
ON/OFF button (3) 36" leads

15 Resistive
10 Amp (1200W) Tungsten

1 HP, 120 VAC

RC615

Timer interface module

15 Resistive
10 Amp (1200W) Tungsten

1 HP, 120 VAC

RC613R

Heavy-duty receiver module

20 Resistive
12.5 Amp (1500W) Tungsten

1.5 HP, 120 VAC
3 HP, 240 VAC

Ratings:

Enclosure: Beige outdoor grade plastic
Maximum Range: 100 ft. See transmitter model RC939
Dimensions: RC613/L, RC615:
4 ½" (11.4 cm) H x 3" (7.6 cm) W x 1 ¼" (4.0 cm) D
RC613R:
7 ¾" (19.7 cm) H x 4" (10.7 cm) W x 3 ½" (8.9 cm) D
Warranty: 1 year

RC939

Handheld 3-Channel Radio Transmitter
• Controls shared pool/spa equipment, including booster pump,
blowers, and lights
• Operates up to three RC600 Series receivers
Model #
C. RC939

Description

Range

Battery

3-Channel Radio Transmitter

100 ft.*

CR2D32

*Range depends on many factors including age of battery, proximity of large metal objects,
location of receiver, and environmental conditions at the time of transmission.

Rating:

Dimensions: 2 ½" (6.35 cm) H x 1 ¼" (3.18 cm) W x ½" (1.27 cm) D
Warranty: 1 year

C.

140

Pool & Spa

D.

E.

PJB Series

Pool/Spa Light Junction Boxes
• For pools or spas, pool/spa combinations,
and landscape applications
• Safe and reliable connection for up to four lights
• Accomodates flexible cords from #16-3 to #10-3 and
non-metallic conduits from ½" to 1"
• Watertight, multi-fixture enclosure
• Easy access groundbar
• 1-year warranty
Model #

Light Connections

Dimensions L x W x D

D.

PJB2175

2

7" (17.78 cm) x 3" (7.62 cm)
x 4" (10.16 cm)

E.

PJB4175

4

7 ½" (19.05 cm) x 4 ¾" (12.01 cm)
x 5" (12.7 cm)

F.

PA114

F.

Accessory
Wall/Post mounting bracket (sold separately)

PE24VA

24-Volt Valve Actuator
• Reliable control of 2-way and 3-way diverter valves
for pool/spa combinations and water features
• Easy-to-adjust cam rotates valves to multiple settings
• Compatible with all pool/spa valves and controls
• 1-year warranty

G.

Model #

Input Voltage

PE24VA

24 VAC

G.
www.intermatic.com

141

Pool & Spa

No matter where you live...
Your pool equipment will experience
power surges and spikes
The new Intermatic PS3000 and IG1200RC3 pool/spa surge
protectors provide industry-leading protection from power
surges and spikes. These unrelenting surge protectors deliver
an unmatched 3-year product warranty and a $7,500
connected equipment warranty. They provide the perfect
add-on for pool and spa equipment. Don’t let a power surge
burn a hole in your wallet. Safeguard your pool/spa equipment
with a heavy-duty surge protector from Intermatic.
An estimated $250-$500* million dollars a year is lost from
property damages caused by power surges. Your new pool
pad equipment can cost over $3000 to replace.

*Based on analysis of insurance claims vs. cloud-to-ground lightning flash data by the National Lightning Detection Network

142

Pool & Spa

NEW
PS3000

Pool and Spa Surge Protective Device
• Meets ANSI UL1449 3rd Edition Standards
• 120/240 VAC single split phase SPD for use
on a variety of pool equipment
• Green LED Protection Indicator
• Type 4x enclosure
• ½" x 20 threaded nipple (weatherproof and UV resistant)
• TPMOV® Technology
• 3 modes of protection
• 3 leads
• 18" lead length
• 10 gauge leads
• 3-year warranty
• $7,500 connnected equipment warranty
Model #

PS3000

Service
Voltage
120/240 VAC

SPD
Type

Nominal
Discharge
Current

1 or 2

10kA

MCOV*
L-N

L-L

150V

300V

Wiring
SCCR**
Configuration

Voltage Protection
Rating (VPR)
L-N/G

L1, L2, L/N-G

20kA

N-G

600

L-L
900

*MCOV Maximum Continuous Operating Voltage
**SCCR Short Circuit Current Rating

IG1200RC3

Plastic Housing
• Green LED Protection Indicator
• Type 3R rainproof enclosure
• 5.65" (14.35 cm) H x 4.18" (10.62 cm) W x 3.33" (8.46 cm) D
• 3 modes of surge protection (L1-N,L2-N,L1-L2)
• 3 leads
• 30" lead length
• 3-year warranty
• $7,500 connnected equipment warranty

Model #

Service
Voltage

Type

Wiring
Configuration

Nominal
Discharge
Current

MCOV*

IG1200RC3

120, 240 VAC

1 or 2

L1, L2, N/GND

20 kA

150 L-N, N-G

SCCR** Voltage Protection
Rating (VPR)
L-N/G
50 kA

700

L-N

L-G

N-G

L-L
1200

300 L-L, L-G
*MCOV Maximum Continuous Operating Voltage
**SCCR Short Circuit Current Rating

www.intermatic.com

143

Pool & Spa
A.

B.

PA600

156T4042A

• Fits in single-gang junction box
• Rated for outdoor installation
• Disconnects electrical equipment from its power
source in case of emergency

• Coordinated control for pool/spa heaters and
filter pumps
• Turns OFF gas pool/spa heater before filter pump
shuts down to extend heater life

Emergency Shut-Off Switch

A.

Model #

Voltage

PA600

120/240 VAC

Fireman Switch

B.

Model #

Switch Rating

156T4042A

10 Amp, 250 VAC Maximum

Ratings:

Electrical Rating: 1 HP, 120 VAC, 3 HP, 240 VAC,
20 A Resistive, 120, 240 VAC DPST
Housing: Electrical grade plastic
Faceplate: Beige powder coated steel

C.

D.

21T166A & 21T156A

22T904A

• Great for mounting toggle switches and GFCIs inside
any Intermatic pool/spa power or load center
• Connects to back panel of power and load centers

• Additional fastener/retainer kit is required per
NEC Article 408.36 (F) –2005

Standoff Posts

Back-Feed Retainer Kit

Model #
Model #

144

Quantity

C. 21T166A

2

21T156A

4

D.

22T904A

Pool & Spa

Enclosures
and Accessories

P a r k i n g Lot Light ing
Entry Lighting

Bell Ringing

Outdoor Lighting
Pools

Security Lighting
Pumps

Spas

Water Heaters

Lobby Lighting
www.intermatic.com

145

Enclosures and Accessories

Not Sure Which Enclosure
Works for Your Time Switch?
Find Your Enclosure in 5 Easy Steps
1. Do you need an enclosure for an
or
time switch?
2. Do you need an indoor or outdoor enclosure?
3. Do you need a plastic or metal enclosure?
4. Do you need a compact or oversized enclosure?
5. Will your enclosure be surface or flush mounted?

Match your answers with the applicable
enclosure on the following pages.

146

Mounting Bracket

20 Gauge
Steel

Lockable
Hasp

Enclosures and Accessories

Corrosion
Resistant Paint

Knockouts (5)
Rainproof
Gasket
2T511GA Shown

www.intermatic.com

147

Enclosures and Accessories

Indoor Steel Enclosure
Type 1 Enclosure
• Drawn steel with gray powder coat paint finish
• Combination ½" and 3 ⁄4" nominal knockouts with one on back and each
side of enclosure, and two on bottom
• Convenient mounting holes
•L
 ockable hasp holds door closed
Model #
A. 2T2040GA
A.

Color

HxWxD

Gray

7 3⁄4 " x 5" x 3"

Accepts a wide range of Intermatic time switches, including most T100, T170, T1900, T2000,
C8800, EH, ET1100, ET1700, ET8000, ET90115, and ET90215 Series units

Outdoor Steel Enclosures
Type 3R Rainproof Enclosures
• Drawn steel with gray or beige powder coat paint finish
• Combination 1 ⁄2" – 3 ⁄4" nominal knockouts with one on back
and each side of enclosure, and two on bottom
• Separate grounding terminal
• Convenient mounting holes
• Lockable hasp holds door closed
Model #
B.

Description

Color

HxWxD

B. 2T511GA*

For Time Switch Models That Snap into Enclosures

Gray

9 3⁄8" x 5 1⁄2" x 3 5⁄8"

C. 2T2485GA*

For Time Switch Models That Snap into Enclosures

Beige

9 3⁄8" x 5 1⁄2" x 3 5⁄8"

For Time Switch Models with Carryover

Gray

9 3⁄8" x 5 1⁄2" x 3 5⁄8"

2T2331GA**

*Available for T100, T170, T1900, T2000 ,C8800, EH, ET1100, ET1700, ET8000,
ET90115, and ET90215 Series units
**Available for T100CR, T170CR, T1400, and T1800 Series units

C.

148

Type 3R Rainproof Enclosures
• Heavy-duty industrial grade plastic
• Perfect for high humidity and dust environments
• Combination 1 ⁄2" and 3 ⁄4" nominal knockouts with one on back and
each side of enclosure, and two on bottom
• Lockable hasp holds door closed
Model #

Description

HxWxD

D. 2T2500GA

Gray

9 3⁄8" x 5 1⁄2" x 3 3⁄4"

E. 2T2502GA

Beige

9 3⁄8" x 5 1⁄2" x 3 3⁄4"

F. 2T2926A

Gray with see-through window

9 ⁄8" x 5 ⁄2" x 3 ⁄4"



3

1

D.

3

Available for T100, T170, T1400, T1900, T2000 ,C8800, EH, ET1100, ET1700, ET8000,
ET8215, ET90115, and ET90215 Series units

Enclosures and Accessories

Outdoor Plastic Enclosures

E.

F.
www.intermatic.com

149

Enclosures and Accessories

Flush Mount
Steel Enclosures
Type 1 Rated Enclosure
• Provides a finished, flush appearance
• Heavy-duty construction with hinged door
• Lockable door with key
• Various mounting holes
Model #

Description

A. 2T2365GA* Riveted Mounting

HxWxD

Door
Opening

91⁄8" x 6" x 41⁄8"

11" x 8"

91⁄8" x 6" x 41⁄8"

11" x 8"

Bracket

2T308A**

Adjustable Bracket
Mount Locations

*Available for ET1100, ET1700, ET8000, EH, ET90115, and ET90215 series units
**Available for T100, T170, T1900, T2000, and C8800 series units

A.

Surface Mount Bracket
Mounting Brackets
• Mounts to a standard symmetrical rail TS35
according to DIN46277 and EN50022
• Ideal for panel mounting mechanical or
electronic time switch controls
Model #
B. 22T338GR

Description

HxWxD

Surface Mount Snap-in Bracket

6" x 5" x 2"

Accepts a wide range of Intermatic time switches, including most T100, T170, T1900, T2000,

B.

150

C8800, ET1100, ET1700, ET8000, ET90115, and ET90215 series units

E150 Type 1 Enclosure
• Lockable hinged door with latch
• Provisions for mounting ANY Grässlin time control
• Five ½" – ¾" knockouts. One on each side, two on the bottom,
and one on back.

Model #
E. E150

HxWxD
10" x 6.5" x 3.75"
E.

Outdoor Plastic Enclosures

Enclosures and Accessories

Indoor Plastic Enclosure

E200 Type 3R Rainproof Enclosure
• Lockable hinged door with latch
• Provisions for mounting ANY Grässlin time control
• Five ½" and ¾" knockouts with, one on each side, two on the
bottom, and one on back

Model #
F. E200

HxWxD
10" x 6.5" x 3.75"
F.

E300 Compact Type 3R Rainproof
Enclosure
• Lockable hinged door with latch
• Provisions for mounting Grässlin timer modules
•F
 ive ½" and ¾" knockouts with, one on each side, two on the bottom,
and one on back

Model #
G. E300

HxWxD
8.795" x 6.631" x 2.935"
G.
www.intermatic.com

151

Enclosures and Accessories

Accessories

A.

B.

C.

D.

E.

F.

G.

H.

K.

L.

M.

J.

A.

152

Model #

Description

Used With

124T1948

Insulator for T101 & T102 Series - Clear

T101 and T102 Series Time Switches

124T1952

Insulator for T103 & T104 Series - Clear

T103 and T104 Series Time Switches

B.

124T2411A

(10) Insulators for T100 Series - Black, Rigid

T100 Series Time Switches

C.

143T135

DPST Relay with 240 VAC Coil

PF1102 and PF1200 Series

D.

143T136

DPST Relay with 120 VAC Coil

PF1103 Series, RC2200E Series, RC613R, P7103ME

E.

143RC151

DPST Relay with 24 VDC Coil

RC2100FE and RC2100E Series

F.

156PB10398A

2 ON and 2 OFF Trippers

P1100 Series, P1261P, and PB913N84 Series

G.

156T1978A

1 ON and 1 OFF Tripper

T100 Series Time Switches

H.

156T6738A

(10) Insulators for Time Switch Manual Lever

T100 Series Time Switches

J.

22T338GR

Snap-In Time Switch Mounting Bracket

All Pool/Spa Enclosures and T100 Series Time Switches

K.

PA115

(25) OFF Trippers and Screws

T100 Series Time Switches

L.

WG1570-10D

120 VAC Clock Motor

T100 Series Time Switches

M.

WG1573-10D

208-277 VAC Clock Motor

T100 Series Time Switches

Description

Model #

Description

101--00040

Battery holder for ET100

WG433-20D

Motor - Boxed, 208/277 VAC, 60 Hz for T180 and T500

22T338GR

Snap-In bracket for ET Series, T100, T170, T180, T1900,
T2000, & C8800 Series

WG436-20

Motor - Boxed, 480 VAC, 60 Hz for WH10 and WH30

WG630D

Motor - Boxed, 125 VAC, 60 Hz

WG720-10D

Motor - Boxed, 125 VAC, 60 Hz for T2000 Series

WG730-14D

Motor - Boxed, 125 VAC, 60 Hz for R8800, T1900, T1970,
T8800 Series

WG733-14D

Motor - Boxed, 208/277 VAC, 60 Hz for R8800, T1900,
T1970, T8800 Series

WG736-14D

Motor - Boxed, 480 VAC, 60 Hz for R8800, T1975E, and
T1976E Series

Electronic Timers

ET9100

Mechanical Timers

ET90000 replacement door assembly for 4, 8, 12, 16-circuit
models

ET9232

Ethernet Module for upgrade or replacement

ET9250

4-circuit module for upgrade or replacement for ET90000 4,
8, 12, 16-circuit models

22--00012

4" Metal DIN Rail

156--01318A

DTAV40 Retro fit plate assembly

WG750-10

Motor - Boxed, 125 VAC, 60 Hz for C8845

DC-FME

Clear dust cover for Grässlin FMD Electronic

WG760-10

Motor - Boxed, 125 VAC, 60 Hz for C8825 (timer obsolete)

DC-FME-A

Clear dust cover for Grässlin FM Mechanical

WG770-10

Motor - Boxed, 125 VAC, 60 Hz for C8866

DT-B

Bracket mount for DTAV40 series timer mechanism

WG770-10D

Motor - Boxed, 125 VAC, 60 Hz for C8865

FM-FU

FM1 Flush mount housing kit

WG773-10

Motor - Boxed, 208/277 VAC, 60 Hz for C8866

FM-SU

FM1 Surface/DIN Rail Kit

WG780-12D

Motor - Boxed, 125 VAC, 60 Hz for C8835

MB-DIN

DIN Rail mounting base for FM2D50

WG790-11D

Motor - Boxed, 125 VAC, 60 Hz for C8815

BEZ-55BLACKU

Bezel adapter for UWZ48E, black, 55 mm sq.

156T1948A

BEZ-55GRAYU

Bezel adapter for UWZ48E, gray, 55 mm sq.

Trippers (1) Set (ON/OFF/ON Cutout) for T170, P171, T1400,
and T1800 Series

BEZ-72PU

Bezel adapter with pins for 3-hole pattern for UWZ48E, gray,
72 mm sq.

156T1949A

Tripper variable (10 to 60 minutes) for Model T185

156T1950A

BEZ-72U

Bezel adapter for UWZ48E, gray, 72 mm sq.

Trippers (12 ON or OFF) for T1900, T2000, C8800, R8800
and T8800 Series

G-55U

Gasket for all FWZ55 flush mount models

156T1954A

14 Pins for R8800 and T8800 Series

G-72U

Gasket for all FWZ72 flush mount models

156T1957A

Skipper screws (3 per package)

MB-48V

Mounting base for UWZ48V

156T1978A

Trippers (1 ON / 1 OFF) for T100, T7000, and WH40

156T2548A

Trippers 7 Sets (ON / OFF) for T7400 and T7800 Series

156T3085A

3 Skipper Screws for T170, P171, T1400, T1800
and WH Series

Grässlin by Intermatic

Metal Trippers

Hour Meters

Mechanical Timers
107T119

Tripper (silver) for T8800 and R8800 Series

107T73

Day Wheel Pin for T8800 and R8800 Series

156T3230A

Trippers (1 ON / 1 OFF / 1 On Cutout) for WH Series

119T86A

Transformer for T8845PV

156T3492A

Trippers WH40

124T1948

Insulator for single pole time switches

124T1952

Insulator for double pole time switches

107SB189

124T2097

Plastic Insulator for T8800 and R8800 Series

124T2247

Insulator old style replaces 124T1607

ON trippers for HB11, HB35R, HB112C, HB113C, HB114C,
AL300RTW, AL600TW, AL900TW, AL60TW, and ML Series
Transformer Timers

131T68GA

125 VAC, 60 Hz motor and carryover T7400BC and
T7800BC Series

107SB192

OFF Trippers for HB11, HB112C, HB113C, HB114C,
AL300RTW, AL600TW, AL900TW, AL60TW, and ML Series
Transformer Timers

133T1115A

Toggle switch for T8800 and R8800 Series

107SB216

ON trippers for HB31R and P1121

133T698A

Replacement snap switch for T1970 Series

107SB217

OFF trippers for HB31R and P1121

133T700A

Micro switch for T8800 and R8800 Series

107SB234

OFF trippers for HB35R

133T701A

Replacement snap switch for T1900 and T2000 Series

107TN221

133T773A

Replacement snap switch for C8800 Series

OFF trippers for TN, PB, TB Series, P1101, P1131, P1161,
P1261, AL300TPWS, AL600TPWS, and AL900TPWS

156EB1945A

Trippers (2) Sets (ON / OFF) for E1020, E1022, EB11,
EB11R, and WH21

107TN222

ON trippers for TN, PB, TB Series, P1101, P1131, P1161,
P1261, AL300TPWS, AL600TPWS, and AL900TPWS

WG1380-11

Motor - Boxed, 125 VAC, 60 Hz for T1400BCR

Transformer – 100 Watt

Enclosures and Accessories

Model #

Plastic Trippers

Pool and Spa

WG1383-11

Motor - Boxed, 208/277 VAC, 60 Hz for T1800BCR

119T267

WG1570-10D

Motor - Boxed, 125 VAC, 60 Hz for T101, T103, and T105

119T340

Transformer – 300 Watt

WG1571-10D

Motor - Boxed, 125 VAC, 50 Hz for T101, T102, T103, T104,
T105, T100R201, and WH10

124T2530A

8-pole buss bar assembly

124TP2608A

4-pole buss bar assembly

WG1573-10D

Motor - Boxed, 208/277 VAC, 60 Hz for T102, T104, WH10
and WH30

133RC1144

Pressure sensing momentary air switch 3 A

WG1574-10D

Motor - Boxed, 208/277 VAC, 50 Hz for T100R301

143PS307

DPST relay with 24 VDC coil

WG1576-10D

Motor - Boxed, 480 VAC, 60 Hz for WH40, WH70 and WH80

143RC126

Bi-Stable Relay SPDT, 1 H.P.-120 VAC, 2 HP - 240 VAC

WG1600-11

Motor - Boxed, 125 VAC, 60 Hz for T7400B and T7800B

143RC140

120 VAC Coil

WG1603-11D

Motor - Boxed, 208/277 VAC, 60 Hz for T7400B and
T7800B

143T135

Four function stepper relay

143T136

Double pole single throw relay with 240 VAC coil

WG190-15D

Motor - Boxed, 125 VAC, 60 Hz

143T145A

Double pole single throw relay with 120 VAC coil

www.intermatic.com

153

Enclosures and Accessories

Model #

Description

156PA13713A

½" non-metallic hub kit for direct connection to
underwater pool lights

156PA13714A

¾" non-metallic hub kit for direct connection to
underwater pool lights

156PA13715A

1" non-metallic hub kit for direct connection to
underwater pool lights

156PA14336A

½" metallic hub kit for direct connection to underwater
pool lights

Description

Pool and Spa
146MT579

Large black knob

148FD5024

Plate for FF5MH

148FD5025

Plate for FF5M

148FD5029

Plate for FF60MH

148FD5030

Plate for FF6H, FF36H and FF46H

148FD5031

Plate for FF6HH

148FD5032

Plate for FF12H, FF312H and FF412H

148FD5033

Plate for FF12HH and FF312HH

148FD5034

Plate for FF2H and FF32H

148FD5035

Plate for FF32HH

Spring-Wound Timers

156PB10398A

(2) ON (2) OFF trippers for P1000 series timer

156T4042A

Heater control (Fireman) switch kit

178PA28A

Freeze protection thermostat for P1353ME digital control

178T24

½" metallic hub kit for direct connection to underwater
pool lights

21T156A

Freeze protection thermostat for PF series freeze
protection models

148FD5036

Plate for FF4H and FF34H

148FD5037

Plate for FF34HH

22T904A

Hold-down kit for circuit breakers

148FD5038

Plate for FF30MH

24T5265A

Snap-in bracket for (2) wiring devices

148FD5039

Plate for FF15MH

CA8750

CA USB stick with base

148FD5052

Plate for FD5MW

PA102

Replacement thermostat relay assembly for
PF1202T and PF1222TB

148FD5054

Plate for FD15MHW

148FD5056

Plate for FD30MHW

148FD5059

Plate for FD6HW and FD46HW

148FD5060

Plate for FD6HHW

148FD5061

Plate for FD12HW and FD312HW

148FD5062

Plate for FD12HHW

148FD5063

Plate for FD2HW and FD32HW

148FD5064

Plate for FD5M

148FD5066

Plate for FD15MH

Electronic 24 Hr 240 VAC, 50/60 Hz replacement clock kit
for mechanical PB clock

148FD5068

Plate for FD30MH

148FD5070

Plate for FD60MH

24 Hr. panel mount timer, 120 VAC for PF and RC
series products

148FD5071

Plate for FD6H, FD36H and FD46H

Wireless I-Wave panel mount receiver for P1353ME and/or
P4243ME mechanisims (PE950 transmitter required)

148FD5072

Plate for FD6HH

148FD5073

Plate for FD12H

148FD5075

Plate for FD2H and FD32H

148FD5076

Plate for FD4H and FD34H

148FD5077

Plate for FD15MAC

148FD5078

Plate for FD30MAC

148FD5079

Plate for FD60MAC

PA114

Plastic pool/spa light junction box mounting bracket

PA115

25 OFF trippers only and screws

PA117

Replacement latch kit

PA120

Double pole single throw relay with 24 VAC coil

PA122

Water temperature sensor for PE650 transceiver (I-Wave)

PA600

Pump shut-off switch

PB313EK

Electronic 24 Hr 120 VAC, 50/60 Hz replacement clock kit
for mechanical PB clock

PB314EK
PB913N66
PE650
PE653

Wireless 5-circuit pool/spa/variable speed
receiver (MultiWave)

PE953

Wireless hand held transmitter for all Wave Series products

PJB2175

Plastic pool/spa light junction box - two light capacity with
conduit sizes from ½" to 1"

PJB4175

Plastic pool/spa light junction box - four light capacity with
conduit sizes from ½" to 1"

148FD5080

Plate for FD4W and FD34HW

RC117

Air tubing - 75 ft. long

FD12HHP

Plate for FD12HH

RC122B

Air tubing - 25 ft. long with RC4G button

FD15MP

Plate for FD15M and FD415M

RC127B

Air tubing - 75 ft. long with RC4G air button

FD15MPW

Plate for FD15MW

RC150

Air tubing - 500 ft. long

FD30MP

Plate for FD30M and FD430M

RC510

Tube coupler - 10 units

FD30MPW

Plate for FD30MW and FD430MW

RC6F

Air button for gunite/fiberglass construction - 150 ft. range

FD60MP

Plate for FD60M, FD360M and FD460M

FD60MPW

Plate for FD60MW and FD460MW

Replacement Plates
24EB5495

Replacement plate for E1120, KM2ST-1G & KM2SW-1G

FF15MP

Plate for FF15M, FF315M and FF415M

24EB5524

Replacement plate for E1221, KM2ST-2D & KM2SW-2D

FF30MP

Plate for FF30M, FF330M and FF430M

FF60MP

Plate for FF60M, FF360M and FF460M

176ET10A

Surge Suppressor - for switching inductive 240 VAC
nominal loads

176ET9A

Surge Suppressor - for switching inductive 120 VAC
nominal loads

AG1BRKT

L bracket for AG series

Spring Wound Timers

154

Model #

Pool and Spa

146MT573

Small ivory knob

146MT574

Small white knob

146MT575

Small almond knob

146MT577

Large white knob

Surge

Enclosures and Accessories

Reference

Reference
Timer Selection Chart
Cross Reference
IP Classifications
Glossary
Switch Type
www.intermatic.com

155

Reference
156

Timer Selection Chart
Mechanical/

Time Switch Type

24-Hr, 7-Day or 365 Day

# of Circuits

Electronic

Amp

Switch Rating

Rating

Mechanical

Auto-Voltage or Multi-Voltage

24-Hr. or 7-Day

1

40

SPDT, DPDT

Mechanical

General Purpose

24-Hr.

1

40

SPST, SPDT,
1.N.O/1.N.C, DPST

Mechanical

24-Hr. with Skipper

24-Hr.

1

40

SPST, SPDT,
1.N.O/1.N.C,
2.N.O/2.N.C,
DPDT, 4-PST

Mechanical

24-Hr. with Skipper

24-Hr.

1

20

SPDT

Mechanical

Short Range Cycle Timer

10, 30 min. 1, 4-Hr.

1

20

SPDT

Mechanical

Percentage Cycle Timer

30 sec., 1, 3, 5, 10, 30 Min.
1, 4 Hr.

1

20

SPST

Mechanical

Irrigation/Sprinkler

24-Hr.

1

15-30

SPST, DPST

Mechanical

7-Day with Photo Control

7-Day

1, 2, & 3

15

SPDT

Mechanical

Compact 7-Day

7-Day

1

20

SPDT

Mechanical

7-Day Dial With/Without
Carryover

7-Day

1

40

4-PST

Mechanical

Water Heater

24-Hr.

1

40

DPST

Mechanical

Astronomic Dial with Skipper

7-Day

1

40

3-PST

Mechanical

Defrost Timer

24-Hr.

1

40

N/A

Mechanical

In-Wall Spring Wound

Decorator and Commercial Style

1

15

Varies

Mechanical

In-Wall Mechanical

24-Hr.

1

20

SPST

Electronic

Auto-Voltage 120-277 VAC

24-Hr. or 7-Day

1

40

SPDT, DPDT

Electronic

24-Hour Electronic
Multi-Voltage

24-Hr.

1&2

30

SPST, DPST

Electronic

7-Day (Weekly) Electronic
Multi-Voltage

7-Day

1&2

30

SPST, SPDT,
DPST

Electronic

7-Day Astronomic Multi-Voltage

7-Day

1, 2, & 4

30

SPST, SPDT,
DPST

Electronic

ET90000

365-Day

1, 2, 4, 8, 12
& 16

20

SPDT, DPST

Electronic

Water Heater

7-Day

1

30

SPST, DPST

Electronic

In-Wall

Countdown timers in various
increments

1

15

SPST

Electronic

In-Wall

Programmable Countdown Timer
24-Hr.

1

20

Single Pole/Three
Way

Electronic

In-Wall

Programmable 7-Day

1

15

Single Pole

Electronic

In-Wall

Programmable 7-Day with Astro

1

15/20

Single Pole/Three
Way

Electronic

In-Wall

Programmable 7-Day with Astro

1

15

Single Pole/Three
Way

Minimum

Events

ON/OFF Time

Skip-A-Day

Carryover

Astro

Daylight

Product

Catalog

Savings

Series

Page(s)

Time
96 Events for 24 Hr./48
Events for Weekly

15 Min. for 24 Hr./
4 hr 15 min/ 2 hr for
Weekly

12

1 Hr.

10

Yes

Optional

No

No

GM40AV

27

No

No

No

No

T100

32

1 Hr.

Yes

Optional

No

No

T170

33

96

15 Min.

Yes

Optional

No

No

T1900

34

10

5 Sec.

No

No

No

No

C88

38

3% to 97% Cycle
Duration

1 Sec.

No

No

No

No

CT

25

7-Day
versions

60

12 Min.

Yes

No

No

No

R88/T88

39

3 per day

3.5 Hr.

No

Yes

No

No

T51

36

84

2 Hr.

No

No

No

No

T2000

37

3 per day

3.5 Hr.

No

Optional

No

No

T74/T78

37

T104-20
(12 ON/OFF per Day)
WH/WQ
(12/46 24-Hr. 12-Weekly)

1 Hr.

No

Yes

No

No

T104-20/
WH/

41

WHQ

28

N/A

N/A

Yes

Yes

Yes

No

V

41

1 to 24/24 Hour Period

15 Min. minimum
ON/OFF Time

No

NO

No

No

DTAV40

90-91

Various increments with/
without “HOLD”

Varies

N/A

N/A

N/A

N/A

FD & FF

54-55

36 (72 Captive Trippers in
20 Minute Increments)

20 Min.

N/A

N/A

N/A

N/A

KM2

56

20 Events

1 Min.

Yes

Yes

No

No

GM40AVE

20

28

1 Min.

No

Yes

No

Yes

ET1100

16-17

28

1 Min.

Yes

Yes

No

Yes

ET1700

16-17

28

1 Min.

Yes

Yes

Yes

Yes

ET8000

16-17

4000+

1 Min.

Yes

Yes

Yes

Yes

ET90000

12-14

42

1 Min.

Yes

Yes

No

No

EH

25

N/A

Varies

N/A

N/A

N/A

N/A

EI200

53

1

1 Sec.

N/A

N/A

No

No

EI400

52

7

1 Min.

Yes

Yes

No

No

EI500

49

40/Week

1 Min.

Yes

Yes

Yes

Yes

EI600

48

ST01

50

EJ600

51

14 ON/OFF Per Week

1 Min.

Yes

Yes

Yes

Yes

Reference

Total ON/OFF

157

Reference
Cross

ALR Model #

Intermatic Model #

ALR Model #

Intermatic Model #

FisherPierce Model #

Intermatic Model #

AA-105

K4021C

TC-174

T174, GM40AV

SFT19

K4235

AA-105HA, AA-105W

K4321C

TC-7401B

T7401B, GM40AV-W

Mulberry Model #

Intermatic Model #

AA-1068, AA-1068W

K4023C

TC-7402B

T7402B, GM40AV-W

30825

K4121C

AA-305

K4021C

TC-7801B

T7801B, GM40AV-W

30827, 30829, 30831

K4123C

TC-7802B

T7802B, GM40AV-W

30834

LC4521C

TL-115

K4251

30836

K4524

PC-101R

T101P, GM40AV

30838

K4522

PC-103R

T103P, GM40AV

30840

K4533

PC-104R

T104P, GM40AV

30842

K4535

FC-15M

FF15MC

30850

K4021C

FC-30M

FF30MC

30851

K4123C

FC-60M

FF60MC

30852

K4123C

Arlington Model #

Intermatic Model #

30855

K4321C

DBU1C

WP1100C, WP3100C, WP3103C

30868

K4221C

60HC

WP3100C, WP3103C

Paragon Model #

Intermatic Model #

DBUL1

WP1100WC

1015-00RS

T1975

DBUL1DC

WP1020C

1015-40TS

T1975E

DBVSeries

WP1000RC, WP1000HRC

4001-00

T101, GM40AV

FisherPierce Model #

Intermatic Model #

4001-00M

T101M, GM40AV-M

FA-105

K4021C

4001-00-RT

T101, GM40AV

FA-105-W

K4321C

4002-20, 4002-71

T102, GM40AV

FA-1068

K4023C

4003-00

T103, GM40AV

FA-305

K4021C

4003-00M

T103M, GM40AV-M

4003-00-RT

T103, GM40AV

AM-1-A, AM-1-A-NB,
AM-2-A, AM-2-A-NB

K122

AT-15

K4136M, K4421M

AT-168

K4123M, K4423M

AT-19

K4135

AT-30

K4141C

BF-120

LC4521C, K4251

BF-208-277

LC4523

BF-480

K4535

ET3001A

ET1105C

FC12HH

FF12HHC

FC15M

FF15MC

FC30M

FF30MC

FC5M

FF5M

FC60M

FF60MC

JB1000, JB1001

K4536SST

LC-120

LC4521C

LC-208-277

LC4523

LM1000, LM1001

K4536SST

M-120

K1221

M-208-277

LC4523

M-480

K4535

MA512H

FD12HH

MA512HW

FD12HHW

MA515M

FD15MC

MA515MW

FD15MWC

MA530M

FD30MC

MA530MW

FD30MWC

MA560M

FD60MC

MA560MW

FD60MWC

MC-10

K4500

PC-101-R

T101P, GM40AV

PC-103-R

T103P, GM40AV

PC-104-R

T104P, GM40AV

PT-15

K4121C

PT-168

K4123C

PT-19

K4135

SC-10

K4500

SPT-15

K4221C

SPT-168

K4223C, K4123C

SPT-19

K4235

SST-120, SST-240,
SST-IES, SST-PV

K4536SS

TC-101

T101P, GM40AV

TC-101-R

T101R, GM40AV

TC-101R201
TC-103

T103, GM40AV

TC-103-R

T103R, GM40AV

TC-104

T104, GM40AV

TC-104-R

158

T101R201

T104R, GM40AV

TC-104R201

T104R201

TC-173

T173, GM40AV

FE100C
FE101C

ET1105C

FE171C

4003-00S, 4003-00SM

T173, GM40AV

4004-20

T104, GM40AV

FE715C

ET1715C

4004-20S

T174, GM40AV

FL115

K4251

4004-71

T104, GM40AV

FP101

T101, GM40AV

4004-71M

T104M, GM40AV-M

FP101R

T101R, GM40AV

4004-71-RT

T104, GM40AV

FP103

T103, GM40AV

4004-71S

T174, GM40AV

FP104

T104, GM40AV

4005-00

T105, GM40AV

FP104R

T104R, GM40AV

4005-00S

T175, GM40AV

FP171

T171, GM40AV

4006-20S

T176, GM40AV

FP173

T173, GM40AV

4006-21

T106, GM40AV

FP7401B

T7401B

4006-71S

T176, GM40AV

FT15

K4121C

4011-00

T101R, GM40AV

FT168

K4123C

4011-00P, 4011-00PC-RT

T101PCD82, GM40AV

FT19

K4135

4012-20, 4012-71

T102R, GM40AV

N1038-1

K4500

4013-00

T103R, GM40AV

N6401-NS

K4521

4013-00P

T103P, GM40AV

N6690B

LC2000

4013-00PC-RT

T103PCD82, GM40AV

N7760, N7762E

K1221

4013-00S

T173R, GM40AV

N7772E

K1222

4014-20, 4014-71

T104R, GM40AV

N7790B

LC4536LAC

4014-71P

T104P, GM40AV

N7794

LC4535LA

4014-71PC-RT

T104PCD82, GM40AV

N9901S-MHL

K4536SS

4014-71S

T174R, GM40AV

NAT9021

K121

41011-00

T101R201

NFP120

K4521

41014-20

T104R201

NFP277

LC4523

42001-00

T1905

NFP480

LC4535LA

42011-20

T1906

NFP480-ELS

K4535

42013-20

T1976R

NS476-71

K122

44001-00, 44005-00

C8845

NS476-73, NS47681

K121

4912-99

T21001R

SFT15

K4221C

4918-99

T21004R

SFT168

K4223C

Intermatic Model #

Paragon Model #

Intermatic Model #

Paragon Model #

Intermatic Model #

7007-00

T7401B

EC7005/120VAC

ET1725C

P101-00M

T101M, GM40AV-M

EC7005PC/120-240VAC

ET1725CPD82

P101-00P

T101P, GM40AV

EC7005PC/277VAC

ET1725CPD82

P101-00PC-RT

T101PCD82, GM40AV

P101-00PS

T171, GM40AV

P101-00RT

T101,GM40AV

P101-00S

T171,GM40AV

P103-00

T103, GM40AV

P103-00M

T103M, GM40AV-M

P103-00P

T103PCD82, GM40AV

P103-00PC-RT

T103, GM40AV

P103-00PC-RT

T103PCD82, GM40AV

P103-00PS

T173, GM40AV

P103-00RT

T103, GM40AV

P103-00S

T173, GM40AV

7007-20
7007-71

T7402B

7008-00

T7801B

7008-20, 7008-71

T7802B

8045-00

G8045-00

8045-20

G8045-20

8145-00

G8145-00

8145-20

G8145-20

8041-00, 8041-20,
8043-00, 8043-20
8045-00, 8045-20,
8046-00, 8046-20
8047-00, 8047-20,
8141-00, 8141-20

DTAV40

8143-00, 8143-20,
8145-00, 8145-20
8243-20, 8245-20, 8247-20

EC71D/18S/120VAC,
EC71D/18S/240VAC

ET90115C

EC71D/30M/120VAC

ET1725C

EC71D/30M/240VAC

ET90115C

EC71D/30S/120VAC

FM1D20A-120

EC71D/30S/240VAC

ET90115C

EC71D/30S/24VAC

FM1D20A-24

EC72D/120VAC,
EC72D/240VAC

ET90215C

EC74/50S/120VAC,
EC74/50S/240VAC
EL71/120VAC,
EL71/208-240VAC

ET90115C

EL71/277VAC,
EL7100/120VAC

P104-71

T104, GM40AV

ET90115C

P104-71

T104M, GM40AV-M

ET90115C

P104-71P

T104P, GM40AV

EL7100PC/120VAC

ET90115CR

P104-71PC-RT

T104PCD82, GM40AV

EL7100PC/208-240VAC

ET90115CR

P104-71PS

T174, GM40AV

ET91615CR

P104-71RT

T104, GM40AV

P104-71S

T174, GM40AV

PN201-00, PN201-00-RT

K4251

SC201-99

K4500

SWP12H

FF12HC

SWP12HH

FF12HH

SWP15M

FF15MC

SWP15MH

FF15MH

SWP2H

FF2H

SWP2HH

FF32HH

SWP30M

FF30MC

SWP30MH

FF30MH

SWP4H

FF4H

EL7100/208-240VAC

CW201-00, CW201-00-RT

K4121C

CW201-70

K4136M

CW201-71

K4123C

CW201-S-00

K4221C

CW201-S71

K4223C

CW302-00

K4136M, K4421C

CW302-70

K4136M

CW302-71

K4421M

EC11D/120VAC

FM1D20A-120

EC11D/240VAC

FM1D20A-240

EC365DST1/120VAC

ET90115CR

EL7200/120VAC,
EL7200/208-240VAC

ET90215CR

EL7200PC/120VAC,
EL7200PC/208-240VAC

EC365DST2/120VAC
EC365DST2/277VAC
EC4000/120VAC

ET1115C

EC4000/208-277VAC

ET1105C

EC40004/208-277VAC

ET1115C

EC40004PC/120-RT

ET1115CPD82

EC4000PC/120-RT

ET1115C

EC4000PC/120VAC
EC4000PC/208-277VAC

ET1115CPD82

EL712
EL71PC/120VAC,
EL71PC/208-240VAC,
EL71PC/277VAC

ET90115CR

EL72/120VAC,
EL72/208-240VAC
EL72/277VAC,
EL7200/120VAC,
EL7200/208-240VAC

ET90215C

EL72PC/120VAC,
EL72PC/208-240V,
EL72PC/277VAC

ET90215CR

EL74

ET90415CR

SWP5M

FF5M

EL78

ET90815CR

SWP60M

FF60MC

ET100/3WAY, ET100F/3WAY,
ET1100

SWP60MH

FF60MHC

EI400C

SWP6H

FF6H

SWP6HH

FF6HH

SWPD12H

FD12HC

SWPD12HH

FD12HH

SWPD12HH-W

FD12HHW

SWPD12H-W

FD12HWC

SWPD15M

FD15MC

ET1100/3WAY

EC4004/120VAC

ET1100/W

EC4004/120V-RT

ET1100F

EC4004/208-277VAC

ET90415CR

ET1105C

ET1100F/3WAY

EI400WC
EI400C

EC4004/208-277VAC-RT

ET1100F/W

EI400WC

EC4004120VAC-RT

ET2000

EI400C

EC4004PC/120VAC

ET1105CPD82

ET2000/W

EI400WC

EC4004PC/120VAC-RT

ET1105CR

ET2000F

EI400C

EC4004PC/208-277VAC

ET1105CPD82

ET2000F/W

EI400WC

EC4004PC/208-277VAC-RT

ET1105CR

EC4005PC/120, 240-RT

ET1125CR

JW10-00, JW10-00PC,
JW10-20, JW10-20PC

EC7000/120VAC
EC7000/120VAC-RT

ET1715C

EC7000/208-277VAC

JW30-00, JW30-00PC,
JW30-20, JW30-20PC
JW5-00, JW5-00PC,
JW5-20, JW5-20PC

CT2000

Precision Model #

Intermatic Model #

8660

K1221

8672

K1222

8690

LC2000

102FAA

K4251

Cross Reference

Paragon Model #

6041-0
6041-20
6043-0

EC7001/120VAC

ET1725C

EC7001/208-277VAC

ET90115C

JW60-00, JW60-00PC,
JW60-20, JW60-20PC

EC7001PC/120VDC

ET1715C

LB201-00, LB201-00-RT

K4021C

EC7004/120VAC

ET1705CR

LB201-71

K4023C

EC7004/208-277VAC

ET90115C, ET1725C

LB201W-00, LB201W-00-RT

K4321C

P101-00

T101, GM40AV

6043-20

DTAV40

6045-0
6045-20
6047-0

159

Reference
Cross
160

Precision Model #

Intermatic Model #

Tork Model #

Intermatic Model #

6047-20

T-15

K4121C

2100

K4121C

6141-0

T-168

K4123C

2101

K4121C, K4136M, K4421M

6141-20

T-19

K4135

2102

K4236C

2104

K4236C, K4123M, K4423M

2105

K4141C

2107

K4136M

2223, 2224

K121

2421, 2422

K1221

2500

K4500

3000

K4021C

3002

K4023C

3002

K4023C

3010

K4321C

3020

K4221C

3121

T105, GM40AV

5500

K4500

7100

T171

7102

T172

7120

T175, GM40AV

7122

T176, GM40AV

7200

T173, GM40AV

7202

T174, GM40AV

7220

T1871BR

Precision Model #

6143-0

Intermatic Model #

DTAV40

6143-20
6145-0
6145-20
6045-0

G8045-00

6045-20

G8045-20

6145-0

G8145-00

6145-20

G8145-20

8690N

LC2000

A-105

K4021C

A-105W

K4321C

A-1068

K4023C

CD101

T101, GM40AV

CD101P

T101P, GM40AV

CD101R-201

T101R201

CD101RH

T101R, GM40AV

CD102

T102, GM40AV

Marktime MH Rhodes
Model #

Intermatic Model #

93303

FF360M

93504

FD32H, FD32HW

93505

FD6H, FD6HW

93507

FD34H, FD34HW

93301

FF315MH

93302

FF330M

93304

FF32H

93306

FF36H

93307

FF312H

93305

FF34H

93312

FF330M

93317

FF312HH

Supco Model #

Intermatic Model #

CD100 Series

T100 Series

M814520

DTAV40-M

S804100, S804120,
S804500, S804520

CD102P

T102P, GM40AV

CD102RH

T102R, GM40AV

CD103

T103, GM40AV

S814100, S814120,
S814500, S814520

CD103P

T103P, GM40AV

T&B Model #

Intermatic Model #

7222

T1872BR

CD103RH

T103R, GM40AV

2CKD

WP1030MXD

7300

T1471BR

CD103S

T173, GM40AV

2CKNM

WP1220C

7302

T1472BR

CD104

T104, GM40AV

CKMD

WP1010HMXD

8001

T1905

CD104-20

T104-20, WHAVQ4

CKNM

WP1100C, WP3100C, WP3103C

8004

T1906

CD104P

T104P, GM40AV

CKSDV

WP1010MXD

8007

T1975

CD104R-201

T104R201

Taymac Model #

Intermatic Model #

8008

T1976

CD104RH

T104R, GM40AV

MM2440C

WP1020C, WP1220C

8061

C8865

CD104S

T174, GM40AV

MM400C

WP1100C, WP3100C, WP3103C

8121

C8815

CD105

T105, GM40AV

MM740C

WP1150C

8301

C8835

CD105RH

T105R, GM40AV

MM7440C

WP1050, WP1250C

8601

C8865

CD105S

T175, GM40AV

MX3200

WP1010MXD

8602

C8866

CD106

T106, GM40AV

MX3300

WP1010HMXD

1101-0

T101R, GM40AV

CD106RH

T106R, GM40AV

MX6200

WP1030MXD

1101D

T10101R

CD106S

T176, GM40AV

Tork Model #

Intermatic Model #

1101M, 1101M-IAP

T101M

CD115-00

T1905

1101

T101, GM40AV

1101-N

T101P, GM40AV

CD115-00S

T1975

1102

T102, GM40AV

1101-NC

T101PCD82, GM40AV

CD115-20

T1906

1103

T103, GM40AV

1102M

T102M

CD115-20S

T1976

1104

T104, GM40AV

1103-0

T103R, GM40AV

CD115-40

T1975E

1191

T101, GM40AV

1103M, 1103M-IAP

T103M

CD2101R

T21001R

1962

T103, GM40AV

1103-N

T103P, GM40AV

CD2104R

T21004R

2000

K4121C

1103-NC

T103PCD82, GM40AV

ET115

K4251

2001

K4221C

1104-0

T104R, GM40AV

JP-275

K4500

2002

K4236C

1104D

T10404R

M2A

K122

2003

LC4521C, K4521

1104DF

T12404R

M2ANA, M2ANB

K121

2004

LC4523

1104FM

T104R201

P-2275

K4521

2005

K1221

1104M, 1104M-IAP

T104M

P68275

LC4523

2007

LC4536LAC

1104-N

T104P, GM40AV

P-7275

K4535

2008

LC4535LA, K4535

1104-NC

T104PCD82, GM40AV

SD7007-00/20

T7401B

2021

K4251

1191-0

T101R, GM40AV

SD7008-00/20

T7801B

2022

K4253

ET1725C

ST-15

K4221C

1847A, 1847AL, 1847AW,
1847AWL

ST-168

K4223C

ST-19

K4235

DTAV40-M

1847AZ, 1847AZL
1848AZL

ET90215C

Intermatic Model #

Tork Model #

Intermatic Model #

Tork Model #

Intermatic Model #

1962-0

T103R

A506HHW

FD6HHW

DW100A, DW100AY

ET90115C

2000-2

K4123C

A506HW

FD6HW

DW200AY

ET90215C

2000-7

K4236C

A512H

FD12HC

ET90215CR

2003S

LC4521LA

A512HH, A512HHC

FD12HH

DZM200, DZM200-2,
DZM200-3, DZM200-A

2004S

LC4523LA

A512HHW, A512HHWC

FD12HHW

DZS100, DZS100-3,
DZS100A

ET90115CR

2007D

LC4536LAC

A512HW

FD12HWC

2008D

LC4535LA

A515M, A515MC

FD15MC

DZS200, DZS200-2,
DZS200-3, DZS200A

ET90215CR

401A

TN111RM40

A515MH

FD15MH

DZS400A

ET90415CR

5001M

LC4521LA

A515MHW

FD15MHW

E101

5001S

LC4521C, K4521

A515MW, A515MWC

FD15MWC

E101-2, E101-3

5004M

LC4523LA

A530M, A530MC

FD30MC

E101-NC

5004S

LC4523

A530MH

FD30MH

E103

5007M

LC2000

A530MHW

FD30MHW

E103-2

5007S

LC4536LAC

A530MW, A530MWC

FD30MWC

E103-2NC

5008M, 5008S

LC4535LA

A560M, A560MC

FD60MC

E103-3

5021M, 5021S

LC4521LA

A560MH, A560MHC

FD60MH

E103NC

A560MHW, A560MHWC

FD60MHW

E120

A560MW, A560MWC

FD60MWC

E120-2, E120-3, E120NC

5024M, 5024S

LC4523LA

5717-T4, 5717-T5,
5717-T6, 5717-T7, 5717-T8

K4536SST

5717-TM

K4536SS

5717-TZ

K4536SST

5737TM

K4536SS

5737TZ

K4536SST

701A
701A-2G

KM2ST-1G

701AC

ACT120M, ACT120M-24,
ACT120MFS
ACT120MFS-24, ACT120S,
ACT120S-24
ACT120SFS,
ACT120SFS-24, ACT30M

CT2000

ET1105C

ET1125C

ET1125C
ET1105C

EH10

EH10

EH20

EH40

ES101

ET1705C

ES101-2, ES101-2NC
ES103

ACT30M-24, ACT30MFS,
ACT30MFS-24

ES103-2
ES103-2NC

C502H

FF2H

7100-0

T171R

C504H

FF4H

7102-0

T172R

C505M

FF5M

7120Z, 7120ZL

ET90115C

C506H

FF6H

7122ZL

ET90115CR

C506HH

FF6HH

7200-0

T173R, GM40AV

C512H

FF12HC

7200L

T173CR

C512HH

FF12HHC

7200Z

V45471R

C515M

FF15MC

7200ZL

V45471CR

C515MH

FF15HH

7202-0

T174R, GM40AV

C530M

FF30MC

7202L

T174CR

C530MH

FF30MH

7202Z

V45472R

C560M

FF60MC

7202ZL

V45472CR

C560MH

7300Z

V45471R

7300ZL

V45471CR

7302Z

ES103-3

ET1725C

ES103NC
ES120
ES120-2, ES120-3
ES120NC
EW101

ET1705C

EW101-2
EW103
EW103-2, EW103-3

ET1725C

EW103NC
EW120, EW120NC

ET1715C

FF60MHC

K400Z, K400Z-2, K401Z,
K401Z-2

ET90415CR

DCL400 BP

LM2-O-120

K600Z, K600Z-2, K601Z

ET90815CR

DG100

ET1705CR

K601Z-2

ET90415CR

V45472R

DG100-2

ET1725CR

K800Z, K800Z-2, K801Z

ET90815CR

7302ZL

V45472CR

ET90115CR

K801Z-2

ET90415CR

8001U

T1975E

DG100-3, DG180, DG180-2,
DG180-3

8007V

R8815P101C

DGM100

ET90115C

A1200, A1600

ET91615CR

A502H

FD2H

A502HH

FD32HH

A502HW

FD32HHW

A504H

FD4H

A504HH

FD34HH

A504HHW

FD34HHW

A504HW

FD4HW

A505M

FD5M

A505MW

FD5MW

A506H, A506HD

FD6H

A506HH

FD6HH

DGM100-2, DGM100-3,
DGS100, DGS100-2
DGS100-3, DGS180,
DGS180-2, DGS180-3

Cross Reference

Tork Model #

ET90115CR

SS13B, SS13F, SS20, SS20F

EI400C

SS700

STO1

SSA100, SSA100R-24,
SSA200

EI400C

TU40

GM40AV

DTU40

GM40AVE

T920L

T51211BC

DIN100A, DIN101A,
DIN101B

ET90115C

DIN103A

ET90415CR

T930L

T51311BC

DIN200, DIN201B

ET90215C

TW220L

T51211BC

DS200, DS200-2, DS200-3

ET90215CR

TW300L

T51311BC

DT100, DT100-2, DT100-3

ET90115C

DT200, DT200-2, DT200-3

ET90215C

TZ220L, TZ222L,
TZ300L, TZ302L

ET90415CR

DTS100A

ET90115CR

W100

T7401B

DTS200A

ET90215CR

W120

T7801B

DTS400A

ET90415CR

161

Reference
Cross

Tork Model #

Intermatic Model #

Grässlin Old Model #

Intermatic Model #

Grässlin Old Model #

Intermatic Model #

W200

T7401B

KLT6HH

FD6HH

FM1DIGI20-240U

FM1D20-240U

W202

T7402B

KLT12H

FD12HC

GMXDIGI20-O-24

GMXFM1D20-O-24

W220

T7801B

KLT12HH

FD12HH

GMXDIGI20-I-24

GMXFM1D20-I-24

W220L

T7801BC

KLT2H

FD32H

DIGI20E-24

FM1D20E-24

W222

T7802B

KLT4H

FD34H

DIGI20A-24

FM1D20A-24

W222L

T7802BC

KLT6H

FD36H

FM1DIGI20-24U

FM1D20-24U

W300

T7401B

KLT5M-W

FD5MW

DIGI42A-24

FM1D50A-24

W300L

T7401BC

KLT15M-W

FD15MWC

DIGI42E-24

FM1D50E-24

W302

T7402B

KLT15MH-W

FD15MWH

GMXDIGI42-I-24

GMXFM1D50-I-24

W302L

T7402BC

KLT30M-W

FD30MWC

FM1DIGI42-24U

FM1D50-24U

W400, W400A

T7401B

KLT30MH-W

FD30MWH

GMXDIGI42-I-120

GMXFM1D50-I-120

W400AL, W400AL-O

T7401BC

KLT60M-W

FD60MWC

GMXDIGI42-O-120

GMXFM1D50-O-120

W402, W402A

T7402B

KLT60MH-W

FD60MWH

DIGI42A-120

FM1D50A-120

W402AL-O

T7402BC

KLT2H-W

FD2HW

DIGI42E-120

FM1D50E-120

WH2

WH40, WHAVQ4

KLT4H-W

FD4HW

FM1DIGI42-120U

FM1D50-120U

Z400B, Z400B-2

ET90415CR

KLT6H-W

FD6HW

GMXDIGI42-O-12

GMXFM1D50-O-12

ELC71PC/120

KLT6HH-W

FD6HHW

DIGI42A-12

FM1D50A-12

ELC71PC/208-240

KLT12H-W

FD12HWC

GMXDIGI42-I-12

GMXFM1D50-I-12

EL71PC/277

KLT12HH-W

FD12HHW

DIGI42E-12

FM1D50E-12

ELC72PC/120

KLT2H-W

FD32HW

FM1DIGI42-12U

FM1D50-12U

KLT4H-W

FD34HW

GMXDIGI42-I-240

GMXFM1D50-I-240

KLT6H-W

FD36HW

DIGI42A-240

FM1D50A-240

KLT5M-A

FF5M

DIGI42E-240

FM1D50E-240

KLT5MH-A

FF5MH

FM1DIGI42-240U

FM1D50-240U

KLT15M-A

FF15MC

GMX2DIGI42I-24

GMX2FM2D50I-24

KLT15MH-A

FF15MH

GMX2DIGI42I-120

GMX2FM2D50I-120

KLT30M-A

FF30MC

GMX2DIGI42O-120

GMX2FM2D50O-120

ELC72PC/208-240

ET90115CR

ET90215CR

ELC72PC/277
ELC74
ELC78
ELC712

ET90415CR
(Except 24 Volt Models)
ET90815CR
(Except 24 Volt Models)
ET91215CR
(Except 24 Volt Models)

Cooper Model #

Intermatic Model #

KLT30MH-A

FF30MH

GMX2DIGI42I-240

GMX2FM2D50I-240

LiteKeeper 4 - LK4

ET90415CR

KLT60M-A

FF60MC

GM40

GM40AV

LiteKeeper 8 - LK8

ET90815CR

KLT60MH-A

FF60MHC

GM40W

GM40AV-W

Leviton Model #

Intermatic Model #

KLT2H-A

FF2H

GM40Q

GM40AV-Q

EZ Max R08BD-L04

ET90415CR

KLT4H-A

FF4H

GM40QW

GM40AV-QW

EZ Max R08BD-L08

ET90815CR

KLT6H-A

FF6H

GM40M

GM40AV-M

EZ Max R24BD-L16

ET91615CR

KLT6HH-A

FF6HH

DTMV40

DTAV40

Hubbell Model #

Intermatic Model #

KLT12H-A

FF12HC

DTQMV40

DTAV40Q

CX042S042NN

KLT12HH-A

FF12HHC

DTMV40-M

DTAV40-M

CX042S043LN

KLT15MH-A

FF315M

DTQMV40-M

DTAV40Q-M

KLT30MH-A

FF330M

WHQ4

WHAVQ4

CX042S00SPN

KLT60MH-A

FF360M

WHQ7

WHAVQ7

CX082S082NM

KLT2H-A

FF32H

KLT4H-A

FF34H

KLT6H-A

FF36H

CX042S04TNN

CX082S083LM
CX082S08TNM

ET90415CR

ET90815CR

CX082S00SPM

162

KLT12H-A

FF312H

WattStopper Model #

Intermatic Model #

KLT12HH-A

FF312HH

LP8 Peanut Panel

ET90815CR

GMXDIGI120-I-120

GMXFM1D20-I-120

Grässlin Old Model #

Intermatic Model #

GMXDIGI120-O-120

GMXFM1D20-O-120

KLT5M

FD5M

DIGI20E-120

FM1D20E-120

KLT15M

FD15MC

DIGI20A-120

FM1D20A-120

KLT15MH

FD15MH

FM1DIGI20-120U

FM1D20-120U

KLT30M

FD30MC

GMXDIGI20-O-240

GMXFM1D20-0-240

KLT30MH

FD30MH

GMXDIGI20-I-240

GMXFM1D20-I-240

KLT60M

FD60MC

DIGI20E-240

FM1D20E-240

KLT60MH

FD60MH

DIGI20A-240

FM1D20A-240

KLT2H

FD2H

KLT4H

FD4H

KLT6H

FD6H

For Complete and Current
Cross Reference List Please
Visit www.intermatic.com

Reference

IP Classifications
The Ingress Protection (IP) rating is used to specify the environmental protection for enclosures.
Below is the IP protection definitions in accordance with IEC529. A two-digit code is used to
specify the type of protection. The table below provides a definition of the codes for protection
against solid objects and water.
First Digit

Second Digit

Represents the type of protection against solid objects

Represents the type of protection against water

0

No special protection

0

No special protection

1

Protection against solid objects with a diameter over 50 mm.
No protection against deliberate access, e.g. with a hand, but
large surfaces of the body are prevented from approach.

1

Protection against vertically falling drops of water, such as
condensation.

2

Protection against penetration by solid objects with a
diameter over 12 mm., such as fingers or similar objects.

2

Protection against dripping water falling vertically when the
equipment (enclosure) is tilted at an angle up to 15º from its
normal position.

3

Protection against solid objects with a diameter of more than
2.5 mm., such as tools and wires with a thickness of more
than 2.5 mm.

3

Protection against water falling at any angle up to 60º from the
vertical.

4

Protection against solid objects with a diameter over 1 mm.,
such as tools and wires with a thickness of more than 1 mm.

4

Protection against water splashed against the equipment
(enclosure) from any direction.

5

Protection against the ingress of harmful dust deposits.

5

Protection from water projected from a nozzle against the
equipment (enclosure) from any direction.

6

Complete protection against the ingress of dust

6

Protection against heavy seas or powerful water jets.

7

Protection against water when the equipment (enclosure) is
immersed in water under defined conditions of pressure and
time.

8

The equipment (enclosure) is suitable for continuous
submersion in water under conditions which must be specified
by the manufacturer.

163

Reference
164

Term

Glossary of Terms
Definition
Electrical Terms

Alternating Current (AC)

Electrical current which, when being produced by a dynamo or generator, continually reverses its
direction of travel. The dynamo or generator that produces alternating current is called an alternator. AC
current can be changed to direct current through use of a rectifier. Voltage of AC current can be readily
stepped up or down through use of a transformer.

Amperes (Amps, A)

The basic unit for measuring electric current passing through a line in a given time. Amperage is equal to
power (in watts) divided by voltage (in volts).

Apparent Power
(Volt-Ampere, VA)

The amount of power that appears to be used by the circuit based upon the output of that circuit. The
apparent power is equal to voltage (in volts) times amperage (in amps) for a circuit, times the power
factor of that circuit.

Cycle

One complete reversal of the direction of current flow in a conductor. Used in conjunction with
alternating current.

Direct Current (DC)

Electrical current that flows only in one direction. The most common source of DC is from various types
of storage batteries. DC can also be produced by a generator for use on DC motors and other
applications.

Electromagnetic
Interference (EMI)

Any electrical or magnetic signal found in addition to a supplied signal. Electromagnetic interference is
commonly detected on the power line between a power supply and an energy control or between an
energy control and a load. Electromagnetic interference can adversely affect normal operation by
causing excessively high or low voltages or by causing irregularities in the power supply signal.

Frequency (Hertz, Hz)

The number of cycles per second in alternating current.

Ground Connection

The connection from the device to Earth ground as a return path. This connection is in addition to the
neutral connection and is provided as a secondary return path for safety and emergency use.

Line Connection

The connection from the power supply to the energy control.

Load Connection

The connection from the energy control to the load(s).

Neutral Connection

The connection from the energy control and/or load to the power supply as a return path.

Noise Filter

An electrical noise filter is a network of electrical components designed to offer a comparatively high
resistance to voltages and/or frequencies outside of an acceptable range, generally used to mitigate the
effects of electromagnetic interference.

Overvoltage

An increase in voltage in an electrical circuit for a significant length of time. Overvoltages are typically
caused by sources outside of a building. Overvoltages can cause permanent damage to energy controls
and loads if the energy controls are properly protected.

Power Factor

A measurement of the efficiency of a circuit, between zero and one. The closer a power factor is to zero,
the more energy that is lost within the operation of the circuit. The closer a power factor is to one, the
more energy that is transferred efficiently to the load.

Radio Frequency
Interference (RFI)

A type of electromagnetic interference associated specifically with radio frequency or wireless sources.

Real Power (Watts, W)

The capacity of the circuit for performing work; the actual amount of power used by the circuit over time.
The real power is equal to voltage (in volts) times amperage (in amps) for a circuit.

Surge

Any unsustained increase in electrical energy. Surges include transients and overvoltages.

Surge Suppressor

A device designed to mitigate or prevent the adverse effects of surges. Most surge suppressors are
intended only for specific types of surges within specific operating conditions.

Transient

A brief spike in voltage in an electrical circuit. Transient voltages are commonly in excess of 1,000 volts,
but for a duration of less than 1/1,000 second. Transient voltages are typically caused by sources inside
of a building, between the power supply and other devices. Transient voltages can cause intermittent or
nuisance operation in energy controls, such as not turning ON when scheduled, or the display temporarily
turning OFF.

Traveler Connection

The connection from the energy management system to another device, such that either device can
control the load. Often referred to as a three-way connection. An example would be a light switch at the
top and bottom of a flight of stairs, where either switch could control the stairway light.

Volts (V)

The basic unit for measuring the amount of electrical potential in a conductor. Voltage is equal to power
(in watts) divided by amperage (in amps).

Definition
Product Features

Astronomic

Products with the Astronomic feature are able to calculate sunrise and sunset times based upon the
current date and geographical location, allowing them to automatically control outputs based on sunrise
and sunset times without the use of a photocontrol.

Auto-Voltage

A type of power supply that contains a single connection for multiple voltages or voltage ranges. The
selection of the proper voltage or voltage range occurs automatically within the control.

Dry Contact

Switch externally supplied power that does not have its own source of power for the loads. This type of
contact can switch any load within its ratings.

Duty Cycling

Switching loads ON/OFF on a rotating schedule to reduce energy consumption and reduce peak demand
charges by ensuring that selected loads are not ON simultaneously.

Holiday

An exception from the standard schedule of events. Holidays can be traditional holidays, such as New
Year's Day, or other exceptions, such as maintenance done on the last Friday of every month. During
holidays, the standard schedule of events is generally suppressed and a separate schedule may be used
specifically for that holiday.

Holiday Schedule

A schedule of events different from the standard schedule of events in an energy control meant to be
used only during a defined holiday period.

Independent Circuit

Sometimes called independent channels, referring to the number of loads that can be independently
controlled based on the same time of day control system. Any of the independent circuits may control
more than one load by switching those loads simultaneously.

Multi-Tap

A type of power supply that contains multiple connections that are each for a different voltage or voltage
range.

Multi-Volt

A type of power supply that contains a single connection for multiple voltages or voltage ranges. The
selection of the proper voltage or voltage range is done manually, generally via a switch located near the
connection.

Offset

A configurable difference between a calculated value and the desired control value. For example, sunset
may be offset to occur 15 minutes earlier than calculated.

Override

A secondary control used to manually turn a load ON/OFF when a schedule of events is active on the
primary control.

Pulse

Pre-defined duration for the controlled output to remain in the ON state. Typically, a pulse is only for a
few seconds, such as when used with bells or alarms. However, some controls do allow for significantly
longer durations to simplify scheduling, eliminating the need for separate ON and OFF events.

Zone

A group of circuits or a defined space within a building where energy demand requirements are
sufficiently similar so that safe, convenient, and energy conscious conditions can be maintained
throughout by a single controlling device.

Reference

Term

Ratings
British Thermal Unit (BTU)

A unit of heat equal to 252 calories. The quantity of heat required to raise the temperature of one pound
of water from 62 °F to 63 °F.

Electronic Ballast

A load category referring to any load that utilizes a modern electronic ballast to start, typically found in
LED lighting.

Full Load Amp (FLA)
Ratings

The amount of current used by a motor when it is in normal operation with a load, typically the minimum
amount of current that a motor requires to remain ON.

Inductive Ballast

A load category referring to any load that utilizes a traditional inductive or magnetic ballast to start,
typically found in fluorescent lighting.

Inductive Load

A load category referring to any load that utilizes an inductor, including motors, relays, solenoids, and
transformers.

Lock Rotor Amp
(LRA )Ratings

The amount of current used by a motor when it is powered but not rotating, typically the maximum
amount of current that a motor requires to turn ON.

Pilot Duty Rating

A load category designed to switch the coil of electromagnetic devices such as solenoids, relays,
contactors, or motor starters. The VA rating of the controlling contacts must be equal to or greater than
the sealed VA, not the inrush VA, of the controlled coil in order to prevent excessive contact wear or
contact welding.

Rating

The limits of the ability of a device to operate safely and satisfactorily within its normal environmental
extremes.
165

Reference

Term

Definition
Ratings

Resistive Load

A load category for any purely resistive load, such as a heater. Contact ratings are resistive unless
otherwise marked.

Tungsten Load

A load category referring to any load that utilizes a tungsten filament, typically found in incandescent and
halogen lighting.

Type 1 Enclosure

Any enclosure that meets specific safety and performance testing standards for use indoors, protecting
the enclosed equipment against dust and dirt, and providing protection against incidental contact with the
enclosed equipment.

Type 3R Enclosure

Any enclosure that meets specific safety and performance testing standards for use indoors or outdoors,
protecting the enclosed equipment against dust, dirt, rain, sleet, snow, and ice and providing protection
against incidental contact with the enclosed equipment.

Type 4X Enclosure

Any enclosure that meets specific safety and performance testing standards for use indoors or outdoors,
protecting the enclosed equipment against dirt, rain, sleet, snow, ice, windblown dust, splashing water,
hose-directed water, and corrosion.
Products and Components

Contactor

An electromechanical device used for direct control of a load, comparable to a heavy-duty relay.

Cycle Timer

A specific schedule type that repeats on a frequent basis, also referred to as duty cycle. The schedule
consists of an ON duration and an OFF duration, which repeat continuously. For example, a control could
be set to be ON for 20 minutes, then OFF for 40 minutes, and then turn back ON for 20 minutes, etc.,
repeating every hour. This type of control is commonly used for feeders, misters, blowers, and similar
outputs.

DIN Rail

A specific type of mounting style used by several controls, named for the German Institute for
Standardization “Deutsches Institut für Normung”. Controls with this mounting style are generally small,
low profile devices ideal for custom panel and OEM applications.

Electrically-Held Contactor

A contactor that is electrically held in the open position or the closed position by applying continuous
electrical current to the contactor control circuit.

Lighting Contactor

A contactor specifically designed for controlling filament loads commonly found in the lighting industry.

Mechanically-Held
Contactor

A contactor that requires only a brief supply of electrical current (pulse) to switch between the open
and closed positions. After switching, the contactor is then retained in the new position by means of a
mechanical latch.

Self-Clearing Latching
Contactor

A type of mechanically-held contactor that has a common input for its open and closed position. Each
brief supply of elctrical currrent (pulse) causes the contactor to alternate between its open and
closed state.

Tripper

A tripper is a component used in setting the schedule on a mechanical timer. Each tripper is inserted or
fastened near a representative time slot to inform the control when to turn ON or OFF. Each time the time
slot aligns with the actual time, the tripper makes contact with or “trips” a mechanical connection that
adjusts the output.
Industry Terms

166

Cycling

The action of switching ON or OFF.

Event

A single setpoint within a schedule. Each event generally contains a date, time, controlled outputs, and
an ON/OFF setting. For example, one scheduled event could be to turn all lights on at sunset.

HVAC

Abbreviation for Heating, Ventilation, and Air Conditioning.

HVACR

Abbreviation for Heating, Ventilation, Air Conditioning, and Refrigeration.

Load

The device or devices controlled by the energy control either directly or indirectly through a control
circuit.

Abbreviation Definition

Description

1 x SPST

Single Pole, Single Throw

A simple ON/OFF switch. The two
terminals are either connected
together or disconnected from
each other. An example is a light
switch.

2 x SPST

Single Pole, Single Throw

Equivalent to two SPST
switches controlled by
separate mechanisms.

1 x DPST

Double Pole, Single Throw

Equivalent to two SPST switches
controlled by a single mechanism.

1 x SPDT

Single Pole, Double Throw

A simple changeover switch.
Common (COM) is connected to
the Normally Closed (NC) output
when in the default position.
Common (COM) is connected to
the Normally Open (NO) output
when in the switched position.

2 x SPDT

Single Pole, Double Throw

Equivalent to two SPDT
switches controlled by
separate mechanisms.

1 x DPDT

Double Pole, Double Throw

Equivalent to two SPDT
switches controlled by a
single mechanism.	

Symbol

Reference

Switch Type

167

Reference

Voltage / Phase Diagrams
120 VAC Single Phase

277
277 VAC
VAC Single
Single Phase
Phase

H
H

HH

120 VAC

277
277 VAC
VAC

N
N

NN

G
G

GG

480 VAC Single
120/240
Single Phase
Phase
120/240 VAC
VAC Split
Split Phase
Phase
120/240 VAC Three Phase HLD
240
HLD(High
(High Leg
LegDelta)
Delta)
240 VAC
VAC Thr
Th
HH

120
120 VAC
VAC

120
120VAC
VAC

NN
240
240VAC
VAC
240
240 VAC
VAC
120
120 VAC
VAC
120
120VAC
VAC

480
480 VAC
VAC
240
240 VAC
VAC

HH

HH

240
240VAC
VAC

HH

NN

HH

HH

GG

NN

GG

208
208 VAC
VAC

240
240VAC
VAC

240
240 VAC
VAC
G

G
480
480 VAC
VAC Three
Three Phase
PhaseDelta
Delta

VAC Three Phase Delta
Delta

HH

HH

240
480
120/208
VAC
Wye
240 VAC
VAC
480VAC
VAC
120/208
VAC Three
Three Phase
Phase
Wye

277/480
277/480 VAC
VAC TT

480
480VAC
VAC

480
480VA
V
HH

208 VAC
HH208 VAC
HH
168 240 VAC
240 VAC

120 VAC
120 VAC

HH

H
H 480 VAC
480 VAC

G

G

H

20 VAC Single Phase

N
Phase

H

277 VAC Single Phase

208 VAC

120 VAC Phase
120/240 VAC Split
240 VAC

240 VAC

H

277 VAC 120 VAC
480 VAC

240 VAC

120 VAC

HH

120 VAC120 VAC

120 VAC

H

240 VAC
208 VAC

277 VAC

277 VAC

480 VAC

N

240 VAC

208 VAC

277 VAC

H

N

G

G

G
H

N
G
H

240 VAC

347/600
VAC
ThreePhase
Phase Delta
Wye
240 VAC
Three

277/480
VAC
Three
Phase
Wye
120/240 VAC
Three
Phase
HLD
(HighDelta
Leg
Delta)
480
VAC
Three
Phase
H
480 VAC
480
VAC Single HPhase

600
VAC
120/208
VAC
Three
120/240
VAC
SplitPhase
PhaseWye

120VAC
VAC
277

H

H
240 VAC

120 VAC
277 VAC

H

H

240 VAC

H
H

H

347 VAC

N

480 VAC

480 VAC

G

G

G

G

H
gle
Phase

6

480 VAC

208 VAC

G

G

H

H

N H

480 VAC

N

N

H

HH

480 VAC

H

N

120 VAC120 VAC

N
240 VAC H

H

H

G

H

H
480 VAC Single Phase

480 VAC

480
H VAC

H

H

G

480
VAC
Three
Phase
Delta
VAC
Three
Phase
Wye
120/240277/480
VAC
Three
Phase
HLD
(High Leg Delta)

240 VAC
Phase
Delta
120/208
VACThree
Three
Phase
Wye

Delta)

G

G

Reference

G

240 VAC

120 VAC

H
H

240 VAC

H

120 VAC

H
H

347 VAC

H

480 VAC

H

208 VAC

240 VAC

N

HH

H

480 VAC

N

277208
VACVAC

N

HG

H

480 VAC

G
H

G

G

G

NH
H

120 VAC

120 347
VACVAC

N

240 VAC

G

600 VAC

N

480 VAC

600 VAC

240 VAC

H

208 VAC

G

208 VAC

120 VAC

G

H

N
G

G

H

480 VAC Three Phase Delta

VAC Three
240347/600
VAC Three
PhasePhase
DeltaWye

120/208 VAC Three
Wye
600 Phase
VAC

G

277/480 VAC Three Phase Wye

H

H

347 VAC
H

480 VAC

208 VAC

240 VAC

240 VAC

H

277 VAC

120 VAC

H

H

347 VAC

H

120 VAC

HH

H

HH

600 VAC

N

347 VAC

HH

N

277 VAC

600 VAC

480 VAC

240 VAC

H 208 VAC
G

120 VAC

480 VAC

480 VAC

N
208 VAC

H

G

G

480 VAC
277 VAC

N
480 VAC

G

H

H

G

G

277/480 VAC Three Phase Wye

347/600 VAC Three Phase Wye

169

170



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Create Date                     : 2013:06:20 08:14:26-05:00
Creator                         : Adobe InDesign CC (Macintosh)
Modify Date                     : 2013:06:21 13:54:12-04:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2013:06:21 13:54:12-04:00
Creator Tool                    : Adobe InDesign CC (Macintosh)
Instance ID                     : uuid:8edf326b-23a2-4b80-8e26-afa20d031367
Original Document ID            : xmp.did:F19A7030EE2668118C148796818CCBC3
Document ID                     : xmp.id:5e161ab5-3cfc-49fc-9b62-96a4db4f8a5d
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:23ff559c-7cee-40b3-b68a-e62afc9a1197
Derived From Document ID        : xmp.did:B7DF042F952068118083E003BA25FBF5
Derived From Original Document ID: xmp.did:F19A7030EE2668118C148796818CCBC3
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC (Macintosh)
History Changed                 : /
History When                    : 2013:06:20 08:14:26-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 170
EXIF Metadata provided by EXIF.tools

Navigation menu