Product Detail Manual

2014-10-22

: Pdf 83032-Attachment 83032-Attachment Batch9 unilog

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadProduct Detail Manual
Open PDF In BrowserView PDF
10/1/2014

Thermostats and Controls | Qmark | Product Detail

Thermostats and Controls
Product Type:

THERMOSTAT CONTROLS

Thermostats and Controls Digital Thermostats,
Programmable Thermostats,
Line Voltage Thermostats, and
Controls

Specifications
CATALOG
TH300024
NUMBER
Action
Triac: Silent Operation
Type
12.5A Resistive 2 wire SPST
Watt
Minimum: 2 amp load
Rating
120V
n/a
208V
n/a
240V
3000 watts
277V
n/a
Pilot Duty No
Range (ºF) 40ºF to 85ºF
Differential Accuracy: Within +/- 0.27ºF
Features

Catalog
No.
Action
Type

TH36004
Electronic Switch
15 A Resistive 4 wire DPST
No minimum load

TH400024
Triac: Silent Operation
16.7A Resistive 2 wire SPST
Minimum: 2 amp load

TH110DPP
Microprocessor
16.7 A Resistive 4 wire DPST
No minimum load

n/a
n/a
3600 watts
n/a
No
40ºF to 85ºF
Accuracy: Within 1ºF of
setpoint
Digital, non-programmable
Digital, non-programmable
12.5amp model delivers
model delivers exceptional
exceptional accuracy. Ideal for accuracy. Ideal for radiant
radiant ceiling panels, and
ceiling panels, and baseboard.
baseboard. Not for fan-forced Can be used for fan-forced
heaters.
heaters..
T8775A1009
T8775C1005

2000 watts
n/a
4000 watts
n/a
No
40ºF to 85ºF
Accuracy: Within +/- 0.27ºF

Electronic Switch
24 volt .015 -1.0A @ 30V 2wire

Electronic Switch
24 volt .015 -1.0A @ 30V 2wire

Electronic Switch
24 volt .015 -1.0A @ 30V 5wire

Microprocessor
Wall thermistor

n/a
n/a
n/a
n/a
24VAC
40ºF to 90ºF
Accuracy: Within 1ºF of
setpoint
TH36004

n/a
n/a
n/a
n/a
24VAC
40ºF to 90ºF
Accuracy: Within 1ºF of set

22A
22A
22A
19A
n/a
40ºF to 90ºF
Accuracy Within 1ºF of
setpoint
TH110DPP

Electronic Switch
15 A Resistive 4 wire DPST
No minimum load

Triac: Silent Operation
16.7A Resistive 2 wire SPST
Minimum: 2 amp load

Microprocessor
16.7 A Resistive 4 wire DPST
No minimum load

n/a
n/a
3600 watts
n/a
No

2000 watts
n/a
4000 watts
n/a
No

n/a
3000 watts
4800 watts
n/a
No

Watt
Rating
120V
n/a
208V
n/a
240V
n/a
277V
n/a
Pilot Duty 24VAC
Range (ºF) 40ºF to 90ºF
Differential Accuracy: Within 1ºF of
setpoint
CATALOG
TH300024
NUMBER
Action
Triac: Silent Operation
Type
12.5A Resistive 2 wire SPST
Watt
Minimum: 2 amp load
Rating
120V
1500 watts
208V
n/a
240V
3000 watts
277V
n/a
Pilot Duty No

n/a
3000 watts
4000 watts
n/a
No
40ºF to 85ºF
Accuracy: Within 1ºF of
setpoint
Digital, programmable high
Digital, programmable model
capacity model delivers
delivers exceptional accuracy.
exceptional accuracy. Ideal for Ideal for radiant ceiling panels,
radiant ceiling panels, and
and baseboard. Can be used
baseboard. Not for fan-forced for fan-forced heaters.
heaters.
TH5220D1003
LT186F01

TH400024

Range (ºF) 40ºF to 85ºF
Differential Accuracy: Within +/- 0.27ºF

40ºF to 85ºF
40ºF to 85ºF
40ºF to 85ºF
Accuracy: Within 1ºF of
Accuracy: Within +/- 0.27ºF
Accuracy: Within 1ºF of
setpoint
setpoint
Features Digital, non-programmable
Digital, non-programmable
Digital, programmable high
Digital, programmable model
12.5amp model delivers
model delivers exceptional
capacity model delivers
delivers exceptional accuracy.
exceptional accuracy. Ideal for accuracy. Ideal for radiant
exceptional accuracy. Ideal for Ideal for radiant ceiling panels,
radiant ceiling panels, and
ceiling panels, and baseboard. radiant ceiling panels, and
and baseboard. Can be used
baseboard. Not for fan-forced Can be used for fan-forced
baseboard. Not for fan-forced for fan-forced heaters.
heaters.
heaters..
heaters.
CATALOG T8775A1009
T8775C1005
TH5220D1003
LT186F01
NUMBER
Action
Electronic Switch Electronic Switch Electronic Switch
Microprocessor
Type
24 volt .015
24 volt .015
24 volt .015 -1.0A @ 30V 5-wire
Wall thermistor
-1.0A @ 30V 2- -1.0A @ 30V 2wire
wire
Watt
Rating
120V
n/a
n/a
n/a
22A
208V
n/a
n/a
n/a
22A
240V
n/a
n/a
n/a
22A
277V
n/a
n/a
n/a
19A
Pilot Duty 24VAC
24VAC
24VAC
n/a
Range (ºF) 40ºF to 90ºF
40ºF to 90ºF
40ºF to 90ºF
40ºF to 90ºF
Differential Accuracy: Within Accuracy: Within Accuracy: Within 1ºF of set
Accuracy Within 1ºF of setpoint
1ºF of setpoint 1ºF of setpoint
Features Digital, nonDigital, nonDigital, 24volt programmable 2 stage 5-7
Proportional and Integral non-programmable

http://www.marleymep.com/en/qmark/pd-en-thermostats-and-controls/

1/4

10/1/2014

Thermostats and Controls | Qmark | Product Detail
programmable
24 volt "Round"
model delivers
exceptional
accuracy. (Heat
Only)

programmable
24 volt "Round"
model delivers
exceptional
accuracy. (Heat
and Cool)
MS26 MD26

wire heat and cool thermostat. One touch
temperature control with exceptional
accuracy. Ideal for plenum heaters, and
HVAC systems.

electronic room sensor thermostat with set
point capability, providing exceptional
accuracy. Transmits actual temperature to a
LTR relay.

CATALOG
M601W M602W
M601TPW M602TPW
M611W M612W
NUMBER
Action
Snap Action
Snap Action
Snap Action
Snap Action
Type
SPST DPST
SPST DPST
SPST DPST
SPST DPST
Amp
Model MD26 has Positive OFF
Model M602W has
Model M602TPW has Model M612W has Positive OFF
Rating
Positive OFF
Positive OFF
120V
22A
22A
22A
22A
208V
22A
22A
22A
22A
240V
22A
22A
22A
22A
277V
18A
18A
18A
18A
Pilot Duty No
Yes 125VA
Yes 125VA
Yes 125VA
Range (ºF) 50ºF to 80ºF
45ºF to 75ºF
45ºF to 75ºF
45ºF to 75ºF
Differential +/- 5ºF
+/- 4ºF
+/- 4ºF
+/- 2 1/2ºF
Features These economy thermostats are the snap
These bi-metal snap
Same as M601W and Built-in heat anticipator assures
action type that are used in apartment
action thermostats are M602W except the
closer control of room
construction. Good thermostat for its value. sensetive. Large knob cover mounting cover temperature. These snap action
Ideal for radiant cove heaters and
allow for easy
offer tamper proof
thermostats are more sensitive
baseboard.
adjustment.
feature.
that
CATALOG
M600MTP
M600S
T100 T200
WR651 WR661
NUMBER
Action
Modulation (2 stage)
Simultaneous switching (double
Snap Action with Heat
Creep (Hydraulic) Action
ckt)
Anticipator
Type
DPST
SPST DPST
SPST DPST
Watt
Rating
120V
22A
22A
22A
22A
208V
22A
22A
22A
22A
240V
22A
22A
22A
22A
277V
18A
18A
18A
na
Pilot Duty Yes 125VA
Yes 125VA
Yes 125VA
No
Range (ºF) 50ºF to 80ºF
50ºF to 80ºF
50ºF to 90ºF
40ºF to 85ºF
Differential Accuracy: Within 3ºF of setpoint Accuracy: Within 3ºF of setpoint
+/- 2 1/2ºF
+/- 2ºF
Features One thermostat controls two
Simultaneous control of two
Line voltage thermostat with Extra-sensitive element in
separate heating circuits and
heating loads. Used where the total everything; Performance,
control knob senses radiant
reduces input during light load load slightly exceeds capacity of a reliability, durability, and a heat as well as air
periods. Second stage activates single switch, where two
large knob. Built-in heat
temperature for ultimate
when temperature drops to
thermostats are impractical. Both anticipation assures close
control. May cause slight
approx. 1 1/2ºF below the first switches are calibrated to operate temperature regulation.
radio or television
stage turn-ON temperature.
at approx. the same temperature. Large knob for easy rotation. interference in outlying
fringe areas.
CATALOG
WR80
NUMBER
Action
Snap Action Switch
Type
Amp
Rating

SPST

WR80EP
Snap Action
Switch
SPST

WT11A WT12A

LTR Series

Positive snap action switch

Electronic Relays

SPDT
Nema 4X rated

Microprocessor base design
These electronic relays have been designed
for silent control of high voltage resistive
loads from a low voltage control circuit.
Inductive motor loads can also be controlled
(120V to 240V only). Compatible with 24V
thermostats and accepts analog signal of 010V DC.
The relays can be used with model
LT186F01 electronic room sensor, providing
proportional and integral control. Also can be
tied to building management systems.

120V
25A
208V
22A
240V
22A
277V
18A
Pilot Duty Yes 125VA
Range (ºF) 40ºF to 90ºF
Differential +/- 3ºF
Features Rugged design for garages,
factories, warehouses and
similar commercial and
industrial installations. The
WR80 can control several
heaters by using an external
contactor.
CATALOG
LTR2240
NUMBER
Action
Dual Silent Relay

25A
25A 22A
25A
22A
25A
18A
22A
Yes 125VA
Yes 125VA
40ºF to 90ºF
40ºF to 110ºF
+/- 3ºF
+/- 2 1/2ºF
This explosion
Nema 4X weatherproof
proof room
enclosure. The control has a
thermostat is
SPDT output and can be used
suitable for Class for heating or cooling
1, Group D and
(ventilation) Multi-positional
Class II, Groups E, mounting offers flexibility in new
F, and G locations. or existing installations.
TC1
Models Below
Enclosure protection for
thermostats.

M600THW
M600THB
This wall plate thermometer accurately displays M600THW room temperature within 1 degree Fahrenheit, so White
you can tell in a moments notice if a room is warm thermostat
or cool. This is ideal for zonal control of your room cover with
temperature. No wiring is needed. (battery
built-in
included with the wall plate). Easy to install.
thermometer.
For M600
Series stats.
M600THB Beige
thermostat
cover with
built-in
thermometer.
For M600
Series stats.
Minimum
50pcs
Allow 4 weeks.

http://www.marleymep.com/en/qmark/pd-en-thermostats-and-controls/

2/4

10/1/2014
Type

Thermostats and Controls | Qmark | Product Detail
2 single pole switches.

Material: Impact resistant
polycarbonate. Clear.
Dimensions are: 7"L X 4.28"H
X 2.75" D
Thermostat enclosure kits are
designed to protect the
thermostat. Circulating slots
allow airflow for proper
operation. Guards are lockable
and a key is provided to
maintain security.

Watt
Resistive Inductive
Rating
120V
25A 1/2HP, 8A
208V
25A 1HP, 8.8A
240V
25A 1HP, 8A
277V
22A n/a
Pilot Duty Yes 125VA
Range (ºF) Can be operate in 20 to
140ºF
Differential Accuracy: Within 1.5ºF of
setpoint
Features This dual level temperature
relay may be used to
operate two separate
heating loads by means of a
single low voltage
thermostat. Relay is
mounted in an enclosure.
HEATER MODEL
WALL THERMOSTAT
AWH3150
M601W
AWH3180
M601W
AWH4408
M601W
AWH4404
M601W
AWH4407
M601W
AWH4307
M601W
AWH4303
NA
AWH4508
M601W
AWH4504
M601W
AWH4507
M601W
AWH4503
NA
AWH4506
NA
AWH44083
NA
AWH44043
NA
AWH4306
NA
NOTE: See note 10
CWH1101DSAG
M601W
CWH1151DSAG
M601W
CWH1201DSAG
M601W
CWH1202DSAG
M601W
CWH1207DSAG
M601W
CWH1157DSAG
M601W
CWH1208DSAG
M601W
NOTE: See note 10
CWH1101DS
M601W
CWH1151DS
M601W
CWH1201DS
M601W
CWH1202DS
M601W
CWH1207DS
M601W
CWH1157DS
M601W
CWH1208DS
M601W
NOTE: See note 10
CWH3150
M602W
CWH3180
M602W
CWH3404
M602W
CWH3407
M602W
CWH3307
M602W
CWH3408
M602W
CWH34083
NA
CWH34043
NA
CWH3504
M602W
CWH3507
M602W
CWH3508
NA
CWH35083
NA
CWH35043
NA
CWH3203
NA
CWH3206
NA
CWH3153
NA
CWH3156
NA
CWH3303
NA
CWH3306
NA
CWH3403
NA
CWH3406
NA
CWH3503
NA
CWH3506
NA
NOTE: See note 10
GFR1500
TH400024, M601W, M611W, T100, WR651
GFR2004
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
GFR2404
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
GFR1500T2
TH400024, M601W, M611W, T100, WR651
GFR2004T2
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
GFR2404T2
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
QFG1512IFM
TH400024, M601W, M611W, T100, WR651
QFG2024IFM
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
QFG2224IFM
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
QFG2228IF
M602W, M612W, T200, WR661
QFG1512T2M
TH400024, M601W, M611W, T100, WR651

http://www.marleymep.com/en/qmark/pd-en-thermostats-and-controls/

3/4

10/1/2014

Thermostats and Controls | Qmark | Product Detail

QFG2024T2M
QFG2224T2M
HEATER
MODEL
LFK151
LFK204
LFK304
LFK404
LFK484
NOTE: See note 10
SED1012C
SED1024C
SED1512
SED2024
ECP1024
ECP1524
CRA1512IF
CRA2028IF
CRA2024IF
CRA2224IF
CRA1512T2
CRA2024T2
CRA2224T2
1235
1235P
2435
2435P
CDF548
CDF542
CDF547
CDF558
CDF552
CDF557
NOTE: See note 11
EFF1500
EFF3007
EFF4008
EFF4004
EFF4007
EFF4804
EFF4807
EFF3003
EFF3006
EFF4003
EFF4006
EFF4803
EFF4806
NOTE: See note 12
QCH1101
QCH1151
QCH1202
QCH1207
NOTE: See note 12

TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
WALL
THERMOSTAT
M602W
M602W
M602W
M602W
M602W
TH400024, TH300024, M601W, M611W, T100, WR651
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH400024, TH300024, M601W, M611W, T100, WR651
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH400024, M601W, M611W, T100, WR651
M602W, M612W, T200, WR661
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH400024, M601W, M611W, T100, WR651
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH400024, M601W, M611W, T100, WR651
TH400024, M601W, M611W, T100, WR651
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
MS26, M601W
TH400024, MS26, M601W
MS26, M601W
MS26, M601W
MS26, M601W
MS26, M601W
TH400024, MS26, M601W
MS26, M601W
MS26, M601W
TH400024, MS26, M601W
MS26, M601W
MS26, M601W
MS26, M601W
NA
NA
NA
NA
NA
NA
TH400024, TH300024, M601W, MS26
TH400024, M601W, MS26
TH400024, TH300024, M601W, MS26
TH400024, TH300024, M601W, MS26

Downloads
Product Manuals and Literature
Thermostat Bulletin (All Models) (644KB)

TH110 Bulletin (134KB)

TH300024 Bulletin (242KB)

TH 36004 Bulletin (187KB)

TH400024 Bulletin (286KB)

TH110DPP Instructions (316KB)

http://www.marleymep.com/en/qmark/pd-en-thermostats-and-controls/

4/4



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu