Product Detail Manual
2014-10-22
: Pdf 83032-Attachment 83032-Attachment Batch9 unilog
Open the PDF directly: View PDF .
Page Count: 4
Download | ![]() |
Open PDF In Browser | View PDF |
10/1/2014 Thermostats and Controls | Qmark | Product Detail Thermostats and Controls Product Type: THERMOSTAT CONTROLS Thermostats and Controls Digital Thermostats, Programmable Thermostats, Line Voltage Thermostats, and Controls Specifications CATALOG TH300024 NUMBER Action Triac: Silent Operation Type 12.5A Resistive 2 wire SPST Watt Minimum: 2 amp load Rating 120V n/a 208V n/a 240V 3000 watts 277V n/a Pilot Duty No Range (ºF) 40ºF to 85ºF Differential Accuracy: Within +/- 0.27ºF Features Catalog No. Action Type TH36004 Electronic Switch 15 A Resistive 4 wire DPST No minimum load TH400024 Triac: Silent Operation 16.7A Resistive 2 wire SPST Minimum: 2 amp load TH110DPP Microprocessor 16.7 A Resistive 4 wire DPST No minimum load n/a n/a 3600 watts n/a No 40ºF to 85ºF Accuracy: Within 1ºF of setpoint Digital, non-programmable Digital, non-programmable 12.5amp model delivers model delivers exceptional exceptional accuracy. Ideal for accuracy. Ideal for radiant radiant ceiling panels, and ceiling panels, and baseboard. baseboard. Not for fan-forced Can be used for fan-forced heaters. heaters.. T8775A1009 T8775C1005 2000 watts n/a 4000 watts n/a No 40ºF to 85ºF Accuracy: Within +/- 0.27ºF Electronic Switch 24 volt .015 -1.0A @ 30V 2wire Electronic Switch 24 volt .015 -1.0A @ 30V 2wire Electronic Switch 24 volt .015 -1.0A @ 30V 5wire Microprocessor Wall thermistor n/a n/a n/a n/a 24VAC 40ºF to 90ºF Accuracy: Within 1ºF of setpoint TH36004 n/a n/a n/a n/a 24VAC 40ºF to 90ºF Accuracy: Within 1ºF of set 22A 22A 22A 19A n/a 40ºF to 90ºF Accuracy Within 1ºF of setpoint TH110DPP Electronic Switch 15 A Resistive 4 wire DPST No minimum load Triac: Silent Operation 16.7A Resistive 2 wire SPST Minimum: 2 amp load Microprocessor 16.7 A Resistive 4 wire DPST No minimum load n/a n/a 3600 watts n/a No 2000 watts n/a 4000 watts n/a No n/a 3000 watts 4800 watts n/a No Watt Rating 120V n/a 208V n/a 240V n/a 277V n/a Pilot Duty 24VAC Range (ºF) 40ºF to 90ºF Differential Accuracy: Within 1ºF of setpoint CATALOG TH300024 NUMBER Action Triac: Silent Operation Type 12.5A Resistive 2 wire SPST Watt Minimum: 2 amp load Rating 120V 1500 watts 208V n/a 240V 3000 watts 277V n/a Pilot Duty No n/a 3000 watts 4000 watts n/a No 40ºF to 85ºF Accuracy: Within 1ºF of setpoint Digital, programmable high Digital, programmable model capacity model delivers delivers exceptional accuracy. exceptional accuracy. Ideal for Ideal for radiant ceiling panels, radiant ceiling panels, and and baseboard. Can be used baseboard. Not for fan-forced for fan-forced heaters. heaters. TH5220D1003 LT186F01 TH400024 Range (ºF) 40ºF to 85ºF Differential Accuracy: Within +/- 0.27ºF 40ºF to 85ºF 40ºF to 85ºF 40ºF to 85ºF Accuracy: Within 1ºF of Accuracy: Within +/- 0.27ºF Accuracy: Within 1ºF of setpoint setpoint Features Digital, non-programmable Digital, non-programmable Digital, programmable high Digital, programmable model 12.5amp model delivers model delivers exceptional capacity model delivers delivers exceptional accuracy. exceptional accuracy. Ideal for accuracy. Ideal for radiant exceptional accuracy. Ideal for Ideal for radiant ceiling panels, radiant ceiling panels, and ceiling panels, and baseboard. radiant ceiling panels, and and baseboard. Can be used baseboard. Not for fan-forced Can be used for fan-forced baseboard. Not for fan-forced for fan-forced heaters. heaters. heaters.. heaters. CATALOG T8775A1009 T8775C1005 TH5220D1003 LT186F01 NUMBER Action Electronic Switch Electronic Switch Electronic Switch Microprocessor Type 24 volt .015 24 volt .015 24 volt .015 -1.0A @ 30V 5-wire Wall thermistor -1.0A @ 30V 2- -1.0A @ 30V 2wire wire Watt Rating 120V n/a n/a n/a 22A 208V n/a n/a n/a 22A 240V n/a n/a n/a 22A 277V n/a n/a n/a 19A Pilot Duty 24VAC 24VAC 24VAC n/a Range (ºF) 40ºF to 90ºF 40ºF to 90ºF 40ºF to 90ºF 40ºF to 90ºF Differential Accuracy: Within Accuracy: Within Accuracy: Within 1ºF of set Accuracy Within 1ºF of setpoint 1ºF of setpoint 1ºF of setpoint Features Digital, nonDigital, nonDigital, 24volt programmable 2 stage 5-7 Proportional and Integral non-programmable http://www.marleymep.com/en/qmark/pd-en-thermostats-and-controls/ 1/4 10/1/2014 Thermostats and Controls | Qmark | Product Detail programmable 24 volt "Round" model delivers exceptional accuracy. (Heat Only) programmable 24 volt "Round" model delivers exceptional accuracy. (Heat and Cool) MS26 MD26 wire heat and cool thermostat. One touch temperature control with exceptional accuracy. Ideal for plenum heaters, and HVAC systems. electronic room sensor thermostat with set point capability, providing exceptional accuracy. Transmits actual temperature to a LTR relay. CATALOG M601W M602W M601TPW M602TPW M611W M612W NUMBER Action Snap Action Snap Action Snap Action Snap Action Type SPST DPST SPST DPST SPST DPST SPST DPST Amp Model MD26 has Positive OFF Model M602W has Model M602TPW has Model M612W has Positive OFF Rating Positive OFF Positive OFF 120V 22A 22A 22A 22A 208V 22A 22A 22A 22A 240V 22A 22A 22A 22A 277V 18A 18A 18A 18A Pilot Duty No Yes 125VA Yes 125VA Yes 125VA Range (ºF) 50ºF to 80ºF 45ºF to 75ºF 45ºF to 75ºF 45ºF to 75ºF Differential +/- 5ºF +/- 4ºF +/- 4ºF +/- 2 1/2ºF Features These economy thermostats are the snap These bi-metal snap Same as M601W and Built-in heat anticipator assures action type that are used in apartment action thermostats are M602W except the closer control of room construction. Good thermostat for its value. sensetive. Large knob cover mounting cover temperature. These snap action Ideal for radiant cove heaters and allow for easy offer tamper proof thermostats are more sensitive baseboard. adjustment. feature. that CATALOG M600MTP M600S T100 T200 WR651 WR661 NUMBER Action Modulation (2 stage) Simultaneous switching (double Snap Action with Heat Creep (Hydraulic) Action ckt) Anticipator Type DPST SPST DPST SPST DPST Watt Rating 120V 22A 22A 22A 22A 208V 22A 22A 22A 22A 240V 22A 22A 22A 22A 277V 18A 18A 18A na Pilot Duty Yes 125VA Yes 125VA Yes 125VA No Range (ºF) 50ºF to 80ºF 50ºF to 80ºF 50ºF to 90ºF 40ºF to 85ºF Differential Accuracy: Within 3ºF of setpoint Accuracy: Within 3ºF of setpoint +/- 2 1/2ºF +/- 2ºF Features One thermostat controls two Simultaneous control of two Line voltage thermostat with Extra-sensitive element in separate heating circuits and heating loads. Used where the total everything; Performance, control knob senses radiant reduces input during light load load slightly exceeds capacity of a reliability, durability, and a heat as well as air periods. Second stage activates single switch, where two large knob. Built-in heat temperature for ultimate when temperature drops to thermostats are impractical. Both anticipation assures close control. May cause slight approx. 1 1/2ºF below the first switches are calibrated to operate temperature regulation. radio or television stage turn-ON temperature. at approx. the same temperature. Large knob for easy rotation. interference in outlying fringe areas. CATALOG WR80 NUMBER Action Snap Action Switch Type Amp Rating SPST WR80EP Snap Action Switch SPST WT11A WT12A LTR Series Positive snap action switch Electronic Relays SPDT Nema 4X rated Microprocessor base design These electronic relays have been designed for silent control of high voltage resistive loads from a low voltage control circuit. Inductive motor loads can also be controlled (120V to 240V only). Compatible with 24V thermostats and accepts analog signal of 010V DC. The relays can be used with model LT186F01 electronic room sensor, providing proportional and integral control. Also can be tied to building management systems. 120V 25A 208V 22A 240V 22A 277V 18A Pilot Duty Yes 125VA Range (ºF) 40ºF to 90ºF Differential +/- 3ºF Features Rugged design for garages, factories, warehouses and similar commercial and industrial installations. The WR80 can control several heaters by using an external contactor. CATALOG LTR2240 NUMBER Action Dual Silent Relay 25A 25A 22A 25A 22A 25A 18A 22A Yes 125VA Yes 125VA 40ºF to 90ºF 40ºF to 110ºF +/- 3ºF +/- 2 1/2ºF This explosion Nema 4X weatherproof proof room enclosure. The control has a thermostat is SPDT output and can be used suitable for Class for heating or cooling 1, Group D and (ventilation) Multi-positional Class II, Groups E, mounting offers flexibility in new F, and G locations. or existing installations. TC1 Models Below Enclosure protection for thermostats. M600THW M600THB This wall plate thermometer accurately displays M600THW room temperature within 1 degree Fahrenheit, so White you can tell in a moments notice if a room is warm thermostat or cool. This is ideal for zonal control of your room cover with temperature. No wiring is needed. (battery built-in included with the wall plate). Easy to install. thermometer. For M600 Series stats. M600THB Beige thermostat cover with built-in thermometer. For M600 Series stats. Minimum 50pcs Allow 4 weeks. http://www.marleymep.com/en/qmark/pd-en-thermostats-and-controls/ 2/4 10/1/2014 Type Thermostats and Controls | Qmark | Product Detail 2 single pole switches. Material: Impact resistant polycarbonate. Clear. Dimensions are: 7"L X 4.28"H X 2.75" D Thermostat enclosure kits are designed to protect the thermostat. Circulating slots allow airflow for proper operation. Guards are lockable and a key is provided to maintain security. Watt Resistive Inductive Rating 120V 25A 1/2HP, 8A 208V 25A 1HP, 8.8A 240V 25A 1HP, 8A 277V 22A n/a Pilot Duty Yes 125VA Range (ºF) Can be operate in 20 to 140ºF Differential Accuracy: Within 1.5ºF of setpoint Features This dual level temperature relay may be used to operate two separate heating loads by means of a single low voltage thermostat. Relay is mounted in an enclosure. HEATER MODEL WALL THERMOSTAT AWH3150 M601W AWH3180 M601W AWH4408 M601W AWH4404 M601W AWH4407 M601W AWH4307 M601W AWH4303 NA AWH4508 M601W AWH4504 M601W AWH4507 M601W AWH4503 NA AWH4506 NA AWH44083 NA AWH44043 NA AWH4306 NA NOTE: See note 10 CWH1101DSAG M601W CWH1151DSAG M601W CWH1201DSAG M601W CWH1202DSAG M601W CWH1207DSAG M601W CWH1157DSAG M601W CWH1208DSAG M601W NOTE: See note 10 CWH1101DS M601W CWH1151DS M601W CWH1201DS M601W CWH1202DS M601W CWH1207DS M601W CWH1157DS M601W CWH1208DS M601W NOTE: See note 10 CWH3150 M602W CWH3180 M602W CWH3404 M602W CWH3407 M602W CWH3307 M602W CWH3408 M602W CWH34083 NA CWH34043 NA CWH3504 M602W CWH3507 M602W CWH3508 NA CWH35083 NA CWH35043 NA CWH3203 NA CWH3206 NA CWH3153 NA CWH3156 NA CWH3303 NA CWH3306 NA CWH3403 NA CWH3406 NA CWH3503 NA CWH3506 NA NOTE: See note 10 GFR1500 TH400024, M601W, M611W, T100, WR651 GFR2004 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 GFR2404 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 GFR1500T2 TH400024, M601W, M611W, T100, WR651 GFR2004T2 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 GFR2404T2 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 QFG1512IFM TH400024, M601W, M611W, T100, WR651 QFG2024IFM TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 QFG2224IFM TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 QFG2228IF M602W, M612W, T200, WR661 QFG1512T2M TH400024, M601W, M611W, T100, WR651 http://www.marleymep.com/en/qmark/pd-en-thermostats-and-controls/ 3/4 10/1/2014 Thermostats and Controls | Qmark | Product Detail QFG2024T2M QFG2224T2M HEATER MODEL LFK151 LFK204 LFK304 LFK404 LFK484 NOTE: See note 10 SED1012C SED1024C SED1512 SED2024 ECP1024 ECP1524 CRA1512IF CRA2028IF CRA2024IF CRA2224IF CRA1512T2 CRA2024T2 CRA2224T2 1235 1235P 2435 2435P CDF548 CDF542 CDF547 CDF558 CDF552 CDF557 NOTE: See note 11 EFF1500 EFF3007 EFF4008 EFF4004 EFF4007 EFF4804 EFF4807 EFF3003 EFF3006 EFF4003 EFF4006 EFF4803 EFF4806 NOTE: See note 12 QCH1101 QCH1151 QCH1202 QCH1207 NOTE: See note 12 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 WALL THERMOSTAT M602W M602W M602W M602W M602W TH400024, TH300024, M601W, M611W, T100, WR651 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 TH400024, TH300024, M601W, M611W, T100, WR651 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 TH400024, M601W, M611W, T100, WR651 M602W, M612W, T200, WR661 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 TH400024, M601W, M611W, T100, WR651 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 TH400024, M601W, M611W, T100, WR651 TH400024, M601W, M611W, T100, WR651 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661 MS26, M601W TH400024, MS26, M601W MS26, M601W MS26, M601W MS26, M601W MS26, M601W TH400024, MS26, M601W MS26, M601W MS26, M601W TH400024, MS26, M601W MS26, M601W MS26, M601W MS26, M601W NA NA NA NA NA NA TH400024, TH300024, M601W, MS26 TH400024, M601W, MS26 TH400024, TH300024, M601W, MS26 TH400024, TH300024, M601W, MS26 Downloads Product Manuals and Literature Thermostat Bulletin (All Models) (644KB) TH110 Bulletin (134KB) TH300024 Bulletin (242KB) TH 36004 Bulletin (187KB) TH400024 Bulletin (286KB) TH110DPP Instructions (316KB) http://www.marleymep.com/en/qmark/pd-en-thermostats-and-controls/ 4/4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 4EXIF Metadata provided by EXIF.tools