Brochure
100349-Attachment 100349-Attachment 100349-Attachment 753573 Batch6 unilog cesco-content
2014-05-16
: Pdf 83556-Brochure 83556-Brochure 753573 Batch3 unilog
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
® sPODM SWITCHPOD • SENSOR INTERFACE SWITCH • MANUAL/AUTO ON • LOW VOLTAGE • PUSH-BUTTON SPECIFICATIONS FEATURES Enables Standard Occupancy Sensors to be used for Manual On Operation Alternative Usage as Override Switch for Auto-On Applicaitons Single Gang Decorator Style w/ either 1 or 2 On/Off Switches Soft-Click Push-Buttons Programmable w/o Removing Switch Plate Optional Dual Manual On Operation Optional 3-Way Operation Optional 0-10 VDC Dimming Control PHYSICAL SPECS SIZE (not including ground strap) 2.74” H x 1.68” W x 1.63” D (6.96 cm x 4.27 cm x 4.14 cm) WEIGHT 2 oz MOUNTING Single Gang Switch Box or Low Voltage Ring COLOR White, Ivory, Gray, & Lt. Almond ELECTRICAL SPECS OPERATING VOLTAGE 12-24 VAC/VDC CURRENT 5 mA DIMMING LOAD Sinks < 20mA; ~40 Ballasts @ .5mA each WIRES (all 20 AWG) sPODM (SA): 4 sPODM 2P (2SA): 6 sPODM (SA) 3X: 6 sPODM (SA) D: 5 sPODM (SA) 3X D: 7 RECOMMENDED POWER PACK PP20 ENVIRONMENTAL SPECS OPERATING TEMP 14º to 160º F (-10º to 71º C) RELATIVE HUMIDITY 20 to 90% non-condensing OPTIONS MULTIWAY INTERFACE (3X) • Interfaces w/ other units for 3-way or additional configurations • Only available on single on/off version DIMMING (D) • Enables user control of 0-10 VDC dimmable ballasts COLOR (must be specified) • White, Ivory, Gray, Light Almond • Wall plate provided Commonly required by building codes (such as California Title 24), bi-level lighting control is LOW TEMP/HIGH HUMIDITY (LT) an easy and convenient method of delivering • Device electronics are coated for extra energy savings without inconveniencing corrosion resistance the occupants. The most common bi-level • Operates down to -40º F/C configuration requires one lighting load to be switched on automatically when occupancy is detected by an occupancy sensor, while a second lighting load can be turned on manually by the occupant if desired. Both loads can then be turned off manually or via the occupancy sensor timing out. Sensors with photocells can also be configured with SwitchPods in order to add override off capabilities. SwitchPods are all single gang decorator style devices available as single or dual switch units. Versions are also available that work in 3-way applications and/or have a 0-10 VDC dimming output. Units defaulted to dual manual-on operation are also available. For digital solutions to bi-level lighting applications, nLight-enabled wall stations (WallPods), power packs, and sensors are necessary. OPERATION / WIRING INFORMATION STANDARD (SPODM / SPODM SA) 2P OPTION (SPODM 2P / SPODM 2P 2SA) RED - Power (12-24 VAC/VDC) WHITE - Pole 1 Occupancy Sensor Input BLACK - Common WHITE w/ BLUE STRIPE - Pole 1 Output to Relay WHITE - Occupancy Sensor Input BLUE - Pole 2 Occupancy Sensor Input WHITE w/ BLUE STRIPE - Output to Relay BLUE w/ WHITE STRIPE - Pole 2 Output to Relay note: Default output functionality (Manual On vs. note: Default output functionality (Manual On vs. Auto-On) is determined by model number, but Auto-On) is determined by model number, but re-configurable using push-button sequence re-configurable using push-button sequence 3-WAY OPTION (3X OPTION) YELLOW - Remote Switch I/O YELLOW w/ BLACK STRIPE - Remote Switch I/O ON 1 2 ON OFF ON OFF ON OFF DIMMING OPTION (D OPTION) ON OFF VIOLET - 0-10 VDC Output OFF (wire to VIOLET on ON OFF 0-10 VDC dimmable ballast) OTHER Class 2 Low Voltage Title 24 System Device 5 Year Warranty Assembled in the U.S.A. ORDERING INFO The Push-Button SwitchPod (sPODM) Series of low voltage wall stations interface with standard Sensor Switch occupancy sensors and power packs in order to implement a wide range of single and bi-level switching applications. These switch devices provide an elegant and cost effective way of deploying bi-level lighting control that meet energy and building codes without having to source special sensors or power packs. ON 2P BUTTONS CONTROLS - top two buttons always control the Pole 1 Output - bottom two buttons always ON / OFF control the Pole 2 Output OFF sPODM [# OF SWITCHES/DEFAULT ON OPER.] [3-WAY]* [DIMMING]* [COLOR] [TEMP/HUMIDTY] # OF SWITCHES/DEFAULT ON OPER. 3-WAY* Blank = 1 Switch / Auto-On Blank = None DIMMING* Blank = None SA = 1 Switch / Manual On 3X = 3-Way D = Dimming 2P = 2 Switches (Pole 1 Manual / Pole 2 Auto) Operation 2P 2SA = 2 Switches (Both Poles Manual) COLOR TEMP/HUMIDTY WH = White Blank = Standard IV = Ivory LT = Low Temp GY = Gray AL = Light Almond *Not available with 2 switch (2P) versions 3-Way Manual On Solution w/ Occupancy Sensor: 1-gang A1 Revised 1.31.14 © 2014 Sensor Switch TYPICAL CONFIGURATIONS (note: 3 conductor 18AWG wire is recommended for all wiring) Bi-Level Solution w/ Occupancy Sensor: 1-gang BI-LEVEL (MANUAL ON / AUTO ON) SOLUTION w/ OCCUPANCY SENSOR: 1 GANG sPODM 2P BLU BLK/ORN WHT / BLU STRIPE BLU / WHT STRIPE WHT BLK BLK RED RED WHT A2 PP20 Class 1 Connections BLU BLU WHT WHT WHT BLU MANUAL BLU ON LOAD AUTO ON LOAD SP20 BLK PP20 N RED sPODM SA D WHT BLU BLU RED BLK WHT BLK 0-10 VDC BALLAST GRY RED VIO WHT A4 RED BLK WHT H BLK / ORN Class 1 Connections N H MANUAL ON w/ DIMMING & OCCUPANCY SENSOR BLK RED WHT / BLU STRIPE VIO 3-Way Manual On Solution w/ Occupancy Sensor: 1-gang BI-LEVEL (AUTO-ON MANUALSensor: ON) SOLUTION Bi-Level Solution w// Occupancy 2-gang w/ OCCUPANCY SENSOR: 2 GANG sPODM BLK/ORN WHT / BLU STRIPE WHT BLK BLK RED RED PP20 If sensor also has dimming output, connect sensor VIO wire to SPODM and ballast VIO wire N H WHT Note: If sensor also has dimming output, connect sensor VIO wire to SPODM and ballast VIO wire. Lowest output level always takes precedence. 3-WAY MANUAL ON SOLUTION w/ OCCUPANCY SENSOR BLU Class 1 Connections BLU AUTO ON LOAD WHT WHT WHT PP20 Class 1 Connections RED RED BLK WHT SP20 sPODM SA 3X MANUAL ON LOAD BLU BLU N WHT BLU BLU WHT BLK H BLK / ORN BLK RED BLK RED sPODM SA 3X BLK WHT H LOAD BLK RED RED WHT / BLU STRIPE WHT YEL RED YEL / BLK STRIPE WHT / BLU YEL YEL / BLK STRIPE WHT BLK WHT / BLU STRIPE Note: SPODM (SA) 3X D units should only be used in 3-way applications with SPODM (SA) 3X units (non-dimming) as dimming levels are not communicated between devices. sPODM SA PROGRAMMING INSTRUCTIONS (PLEASE READ ALL 7 STEPS BEFORE PROGRAMMING) 1. Enter programming mode by pressing & holding upper most button until LED flashes rapidly. Release button. 2. Enter the On Mode function by pressing button twice. 3. The current On Mode setting will then be fed out in a sequence of LED flashes as indicated in the table below (e.g., one flash for AutoOn). To change the setting, proceed to step 4 before sequence repeats 10 times. 4. At any time while the switch is flashing back the current On Mode setting, interrupt it by pressing button the number of times for the new desired On Mode setting as indicated in the table below (e.g., press twice for Manual On). Switch will begin to flash back new setting as confirmation. 5. Next, while the switch is flashing back new setting, interrupt it by pressing and holding button until LED flashes rapidly. Release button. 6. As final confirmation and activation of the new setting, press button two times. 7. LED will flash twice indicating acceptance of new setting. If two flashes are not seen, repeat 7 step process. Note: To exit programming mode without saving, wait for blink back sequence to repeat 10 times then return to step 1. Function Number 2 Function Name On Mode Settings (*indicates default setting) Setting Number Pole 1 Pole 2 (2P devices only) 1 Auto-On Manual On 2 Manual On Auto-On 3 (2P devices only) Manual On Manual On 4 (2P devices only) Auto-On Auto-On WARRANTY: Sensor Switch, Inc. warrants these products to be free of defects in manufacture and workmanship for a period of 60 months. Sensor Switch, Inc., upon prompt notice of such defect, will, at its option, provide a Returned Material Authorization number and repair or replace returned product. LIMITATIONS AND EXCLUSIONS: This Warranty is in full lieu of all other representation and expressed and implied warranties (including the implied warranties of merchantability and fitness for use) and under no circumstances shall Sensor Switch, Inc. be liable for any incidental or consequential property damages or losses. TS-SPOD-002A 900 Northrop Road, Wallingford, CT 06492 • 1.800.PASSIVE • FX 203.269.9621 • www.sensorswitch.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Instance ID : uuid:2d9ae9f2-47ae-40a2-a2fe-e746b1fdb4db Original Document ID : adobe:docid:indd:9223b729-f3b6-11dd-9b4a-be903d9e249d Document ID : xmp.id:7929FBD9788AE31181E0BBD4ED643F5A Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:7829FBD9788AE31181E0BBD4ED643F5A Derived From Document ID : xmp.did:F09E09F82906E1118970C2560D86087D Derived From Original Document ID: adobe:docid:indd:9223b729-f3b6-11dd-9b4a-be903d9e249d Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2014:01:31 08:09:10-05:00 Create Date : 2014:01:31 08:09:10-05:00 Modify Date : 2014:01:31 08:09:19-05:00 Metadata Date : 2014:01:31 08:09:19-05:00 Creator Tool : Adobe InDesign CS6 (Windows) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools