6L Champ®FMV LED Series
Floodlight Fixtures
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III
UL Listed & CSA Certified
IECEx / ATEX
Simultaneous Presence
Wet Location, Type 4X, IP66
The Champ FMV
LED Family
FMV LED Series Floodlights are designed
to provide full-spectrum, crisp, white light.
Five versions of the Champ FMV LED are
available, providing ideal solutions for a
wide range of applications.
FMV
Model
Equivalent MH
HID Lamp
Energy
Savings
FMV 5L 100W-150W
Up to
62%!
FMV 7L 150W-175W
FMV 9L 175W-250W
FMV 11L 250W-400W
FMV 13L 400W
Applications:
Five lumen outputs allow for installation
in numerous mounting heights
Locations requiring continuous and
consistent light levels in extreme
ambient temperatures
Areas requiring frequent on-and-off of
lights
Where flammable vapors, gases,
ignitable dusts, fibers or flyings are
present; indoors or outdoors
Where extremely corrosive, wet, dusty,
hot and/or cold conditions exist
Type 4X, marine, wet locations, and
hose-down environments
Indoor and outdoor area lighting in
plants, buildings, and parking areas
Manufacturing plants; heavy industrial,
chemical, petrochemical or
pharmaceutical facilities; platforms;
loading docks; outdoor mounted general
area lighting
Champ FMV LED Benefits:
Enhance safety and productivity
Instant illumination and restrike
Better visibility with crisp, white light
Minimum T4 temperature rating – safely
operate in the most hazardous
environments and any non-hazardous
location
Cold temperature operation / no warm-up
required
“No lights out” feature – if a single LED
fails, others will remain lit from other
drivers – minimum 50% output maintained
Terminals – 3 x 6 sq. mm. for IEC version
Reduce operation and
maintenance costs
Easy installation - compact modular fixture
attaches onto existing SFA6 and SWB6
Energy-efficient technology – use up to 1/2
the power of standard HID luminaires
Provides up to 60,000 hours rated life –
eliminates need for frequent lamp
replacement
Contains no mercury or other hazardous
substances
Reliable performance in any
environment
Shock- and vibration-resistant solid-state
luminaires have no filaments or glass
components that could break – greatly
reduces the risk of premature failure
Operating ambient -40°C to 55°C
Dark sky friendly with optional visor
Standard Materials:
Housing – copper-free aluminum with
Corro-free™ epoxy powder coat
Lens – shatter-resistant glass
Gaskets – silicone
External hardware – stainless steel
Factory-sealed, no external seals
required
LED System:
High brightness light emitting diode
(LED) arrays
Color temperature: 3000K (CRI 82) and
5600K (CRI 65) options available
Advanced heat sink design ensures LED
does not exceed manufacturer’s
temperature ratings across all specified
ambient conditions
LM-80 reports available upon request
Options:
Description Suffix
Fused (only applies to
UNV1 model, not available
for 347V or 480V;
NOT marine or cUL Listed)
(NEC version only) . . . . . . . . . . . S658
Two conduit/cable glands of
like thread installed . . . . . . . . . . S886
Electrical Ratings:
FMV 5L FMV 7L FMV 9L FMV 11L FMV 13L
Voltage Range, VAC 100-277V 50 / 60 Hz
347 / 480V 60 Hz
Voltage Range, VDC 108-250 108-250 108-250 108-250 108-250
Input Power (Nom.) 64 89 121 149 179
Input Amps (Max.) 0.550 0.800 1.083 1.608 1.608
Power Factor >0.85 >0.85 >0.85 >0.85 >0.85
Drivers:
Model 5L - 13L
Standard 90-305 VAC, 50 / 60 Hz;
108-250 VDC
Option 1 347 VAC Model
Option 2 480 VAC Model Accessories (Order
Separately):
Description Cat. No.
Bolt-on visor
(sold separately) . . . . . . . . . . . . DSV1
Bolt-on wire guard
(sold separately) . . . . . . . . . . . . P61
Floodlight slipfitter
(sold separately) . . . . . . . . . . . . SFA6
Slipfitter wall mount adapter
(sold separately) . . . . . . . . . . . . SWB6
Certifications and
Compliances:
DesignLights Consortium®approved for
select models (refer to Ordering Information
for details)
NEC and CEC
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
Class II, Groups E, F, G
Class III
Simultaneous Presence
Wet Locations, Type 4X, IP66
UL Standards
• UL844
UL1598 Luminaires, UL1598A Marine
CSA Standard
CSA C22.2 No. 137
IECEx/ATEX
IECEx UL 11.0054X
Ex nA nR IIC T4 Gc Tamb -30°C to +55°C
Ex nA nR IIC T5 Gc Tamb -30°C to +40°C
Ex tc IIIC T68°C Dc IP66 Tamb -30°C to 40°C
DEMKO 12 ATEX 115535X
Ex II 3 G Ex nA nR IIC T4 Gc Tamb -30°C to
+55°C
Ex II 3 G Ex nA nR IIC T5 Gc Tamb -30°C to
+40°C
Ex II 3 D Ex tc IIIC T68°C Dc IP66 Tamb
-30°C to +40°C
CEPEL Ex-1956/10
1146-1147.qxp 12/16/2013 7:01 PM Page 1146
6L
1147
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2013 Eaton’s Crouse-Hinds Business
6L
Safe, reliable heat transfer
The heat sink was designed to perform in
high ambient temperatures up to +55ºC and
as low as -40ºC. The thick walls of the
castings make for a tough, rugged housing
that keeps the internal driver and LED
temperatures down, allowing them to
perform flawlessly, and protects them from damage. Separated driver
and LED housing allows dust to shed from fixture.
Versatile design
Suitable for hazardous location use in gas
or dust areas. Can be used for outdoor or
indoor applications, and for a wide range of
mounting heights depending on model and
light level requirement. Optics were
specifically designed to give the familiar
and industry-accepted butterfly beam light
pattern.
High efficiency and lumen output
High efficiency drivers and LED arrays provide
reliable low cost operation in harsh and
hazardous environments. Components were
chosen to give industry-leading light output from
an LED flood. Replaceable drivers and LEDs for
ease of maintenance and “no lights out” feature.
Installation and replacement made simple
The full-frame yoke was designed to utilize the SFA6 slipfitter
and SWB6 wall mount bracket (sold separately), making it
ideal for retrofit or new installations. The modular design of
the FMV LED allows for easy driver or LED replacement, and
allows for the addition of the optional visor or guard in the
field. Single cable gland provided with a second plugged
cable entry, if an additional cable gland is needed.
Optional equipment
Cool (C) and Warm (W) white color temperatures available.
Optional visor offered (sold separately) to control light spill.
Optional wire guard offered (sold separately) to protect lens from damage.
Other options available - consult part numbering guide.
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III
UL Listed & CSA Certified
IECEx / ATEX
Simultaneous Presence
Wet Location, Type 4X, IP66
Champ®FMV LED Series
Floodlight Fixtures
1146-1147.qxp 12/16/2013 7:01 PM Page 1147
6L
1148
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2013 Eaton’s Crouse-Hinds Business
6L
Dimensions:
21.0
[532.9]
16.0
[405.9]
6.6
[167.1]
21.75
[552.5]
4.75
[120.7] Ø.55
[14]
Champ®FMV LED Series
Floodlight Fixtures
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III
UL Listed & CSA Certified
IECEx / ATEX
Simultaneous Presence
Wet Location, Type 4X, IP66
Catalog Numbering System:
SERIES
FMV NEC version with Class/Division ratings
NFMV IEC version with Class/Zone ratings
LIGHT SOURCE / INTENSITY
5L 100W - 150W equivalent
7L 150W - 175W equivalent
9L 175W - 250W equivalent
11L 250W - 400W equivalent
13L 400W equivalent
COLOR TEMPERATURE
C5600K (cool white)
W3000K (warm white)
MOUNT
YYoke
VOLTAGE
/
UNV1 100 VAC to 277 VAC 50/60 Hz, 108 VDC to 250 VDC
/
347 347 VAC 60 Hz
/
480 480 VAC 60 Hz
OPTICAL DISTRIBUTION
76 Floodlight pattern optics included
SUFFIXES
M20 20mm metric threads for conduit opening (NFMV only)*
M25 25mm metric threads for conduit opening (NFMV only)*
S658 Fused; for UNV1 only; not for marine or cUL
S886 Two conduit/cable glands of like thread installed
*Required for NFMV. Please specify conduit entry.
SERIES LIGHT
SOURCE COLOR MOUNT VOLTAGE OPTICAL
DISTRIBUTION SUFFIXES
FMV 9L C Y /UNV1 76 S658
ADDITIONAL ITEMS (SOLD SEPARATELY)
DSV1 DSV dark sky visor
P61 Wire guard factory installed
SFA6 Floodlight slipfitter
SWB6 Slipfitter wall mount adapter
/
120 120 VAC 50/60 Hz**
**5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton’s Crouse-Hinds standard Terms and Conditions.
DesignLights Consortium® approved models. Cool white only.
1148-1149.qxp 12/16/2013 7:43 PM Page 1148
6L
1149
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2013 Eaton’s Crouse-Hinds Business
6L
Distance in Feet
Point By Point FC Readings
.35 Fc
MULTIPLIERS FOR OTHER LED FLOODLIGHTS
FMV 13L @ 40 Ft. High; Tilt Angle = 45 Degrees
(Isofootcandles)
Luminaire
Series Wattage Lumens*
FMV 5L 64 4386
FMV 7L 89 6720
FMV 9L 121 8478
FMV 11L 149 10420
*FMV 13L output is 12,940.
.5 Fc 1 Fc 2 Fc 2.5 Fc
Weights:
Model Lbs. Kg.
5L 39.11 17.74
7L 39.16 17.76
9L 39.73 18.02
11L 40.35 18.30
13L 40.35 18.30
Ambient Temperature:
Max. Temp. ºC Cl. I, Div. 2 Cl. I, Zone 2 Simu. Presence Div. 1 and Div. 2 Cl. II, Div. 1 Cl. III
FMV 5L 40 T3C T5 T3A T5 T5
55 T3C T4 - - -
FMV 7L 40 T3C T5 T3A T5 T5
55 T3C T4 - - -
FMV 9L 40 T3C T5 T3A T5 T5
55 T3C T4 - - -
FMV 11L 40 T3C T5 T3A T5 T5
55 T3C T4 - - -
FMV 13L 40 T3C T5 T3A T5 T5
55 T3C T4 - - -
Photometric Data:
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III
UL Listed & CSA Certified
IECEx / ATEX
Simultaneous Presence
Wet Location, Type 4X, IP66
Champ®FMV LED Series
Floodlight Fixtures
1148-1149.qxp 12/16/2013 7:43 PM Page 1149