Product Detail Manual

2014-09-05

: Pdf 84523-Attachment 84523-Attachment 022389 Batch7 unilog

Open the PDF directly: View PDF PDF.
Page Count: 258

DownloadProduct Detail Manual
Open PDF In BrowserView PDF
LAMP & BALLAST CATALOG

H

alco Lighting Technologies is a leader of lamp and ballast solutions
for commercial, industrial, residential and specialty lighting applications.
Established in 1974, Halco is headquartered in Atlanta with distribution
centers in Carlstadt, Cleveland, Houston, Los Angeles and Phoenix.

CONTENTS

43

57

This catalog has been hyperlinked for your convenience.
Click on an image to navigate to each section.

LED LAMPS

COMPACT FLUORESCENT
LAMPS

171

207

77

LINEAR FLUORESCENT LAMPS

213

93

HID LAMPS

227

117

HALOGEN LAMPS

233

135

INCANDESCENT LAMPS

250

155

SPECIALTY LAMPS

ELECTRONIC FLUORESCENT
BALLASTS

ELECTRONIC SIGN BALLASTS

COMPACT FLUORESCENT
BALLASTS

ELECTRONIC HID BALLASTS

ELECTROMAGNETIC HID
BALLASTS

APPENDIX

Halco Lighting Laboratories, located at our Atlanta
headquarters, is our state of the art NVLAPaccredited facility utilized for quality control and
product development.

Halco Lighting Technologies offers one of the most comprehensive product lines in the industry, including
the proprietary brands ProLED®, ProLume®, HaloXen®, Prism® and CoverShield®. Our manufacturing
expertise is put to the test in our state-of-the-art, in-house NVLAP-accredited laboratory.
In addition to superior quality products, Halco contributes to the vibrant and responsible lighting industry
through association membership and knowledge sharing. Together, we focus on key industry issues
including legislation, environmental impact, energy-efficiency and process standards.
Halco focuses on being easy to do business with; illustrated by our knowledgeable and empowered
customer service representatives and online support tools. As your partner, Halco strives to be your only
choice for lamp and ballast products.

LED Product Partner

SERVICE

Knowledgeable, empowered customer service representatives serve as your dedicated in-house
contact. Our representatives receive continuous product and industry training. They are your resource
for product availability, pricing, order fulfillment and technical support.
In addition to our personalized service, Halco’s offers 24/7 electronic support at halcolighting.com, which
is operated by our advanced enterprise software. Halco’s full-feature e-commerce website provides
access to in stock availability, order entry, delivery status and order history for our distributor partners.
You can also locate product information quickly with our online product search or category drill down.
For a comprehensive directory of product literature, compatibility and application information as well as
white papers, visit our online literature library.
Halco’s strategically located, fully stocked regional warehouses provide you maximum service with
minimum transportation time and costs. Halco’s deep inventory levels of lamp and ballast SKUs increases
your ability to service your customers. Every Halco distribution center adheres to our aggressive service
policy to ship orders received by 2:00PM local warehouse time the same day. Will-call service is also
available for your convenience. With distribution centers in Atlanta, Carlstadt, Cleveland, Houston, Los
Angeles and Phoenix, we are able to deliver to over 85% of United States same day or next day.

QUALITY
Lumens: 260 Beam Spread: 32°

Coverage

20'

0'

2'

4'

6'

8'

10'

12'

2.20

18'

2.72

16'

3.44

14'

4.49

12'

6.12

10'

8.81

8'

13.76

6'

24.46

4'

55.00

2'

220.10
PAR36/6WW/WFL/LED2

FC

As part of our commitment to quality and innovation, we operate our own state-of-the-art NVLAPaccredited testing laboratory at our headquarters in Atlanta. Based on a quality management system
outlined in ISO 17025, Halco Lighting Laboratories features a goniophotometer for photometric testing
as well as a temperature-controlled integrating sphere that tests environmentally sensitive products.
We conduct a number of tests according to IESNA standards, including photometric distribution, light
output, color and electrical properties. The Halco Lighting Laboratories product testing facility ensures
continuous quality control and outstanding product performance.
At Halco Lighting Technologies, we are committed to quality and service. We measure our success
by one standard, customer satisfaction. With this in mind, we offer you the following:
Should you encounter any product from Halco Lighting Technologies that fails to perform
according to specifications, contact your account representative immediately. If our
product is found to be defective in either material or workmanship, we will credit your
account or replace the product at no charge. In order to better maintain our standard of
quality, we reserve the right to inspect any defective product.
We make this assurance to clearly demonstrate our commitment to your satisfaction.

PRODUCT

Throughout the years we’ve continued to invest in our partnership by growing our product offering,
leveraging global manufacturing resources and developing a knowledgeable service team. As we look
to the future, Halco remains committed to providing you innovative lamp and ballast products with
unparalleled service.
When you think lamps and ballasts, think Halco.

Solid State Lighting

Compact Fluorescent,
Linear Fluorescent & HID
Lamps and Ballasts

High Performance,
Extended Life and Energy
Saving Halogen-Xenon

®

Halogen and Value Added
Incandescents

Incandescent and Photo/
Projection Lamps

Safety Coated Lamps

LED LAMPS

Halco has one of the most comprehensive LED lamp offerings available in the industry, boasting impressive
savings of up-to 88% in energy costs. Our award-winning LED product line features an unrivaled combination
of efficiency, long life and light output, providing the best overall performance in LED technology. ProLED®
products utilize the highest quality components, including USA and Japanese chips, precision manufactured
optics, optimally engineered drivers and special heat sinks for superior thermal management.

High Power LED Lamps

All high power ProLED® products are specified at 40,000 hours rated life to L70, meaning the lamp will provide
70% of its initial specified lumens at rated life. Backed by a 5-year warranty, these lamps provide consistent
lamp-to-lamp color, precise beam control and reduced maintenance. Our MR, Reflector and PAR lamps are
available in multiple beam spreads, wattages and colors.

JC Type Lamps

Halco’s ProLED® JC lamps are rated up-to 40,000 hours and backed by a 5-year warranty on IP65 Rated and
2-years on standard JC lamps. Available with bi-pin and bayonet base types, these lamps offer reduced
maintenance and do not project heat. ProLED® JC Lamps are available with bi-pin and bayonet base types, in
3000K and multiple colors, 10-18V input voltage range and IP65 rated options for outdoor use.

Energy Efficient Alternatives

Halco’s ProLED® offering features a wide variety of energy efficient alternatives to traditional lamp types. Ideal
for replacement and retrofit, ProLED® lamps include the award-winning Elevator lamps, Chandelier lamps with
cream, chrome and brass base options, Decorative B10 and CA10 lamps, clear and color Sign lamps, colorful
C7 & C9 lamps, Decorative Globe and Linear T8 lamps.

Environmentally Responsible

Halco’s offering of ProLED® lamps contain no mercury or lead (RoHS compliant) and emit no ultraviolet and
infrared radiation.

ENERGY STAR® Rating

Halco’s ENERGY STAR products deliver exceptional features while generating savings for
consumers. For our most current ENERGY STAR products, please visit our literature library at
www.halcolighting.com/download.

COMPACT FLUORESCENT LAMPS

Compact Fluorescent lamps are specified for a growing number of applications, especially where the objectives
are energy savings and reduced maintenance costs. In fact, they save up-to 80% in energy costs and last up-to
ten times longer than standard Incandescent lamps. ProLume® has become a popular choice due to our wide
range of high performing, reliable products.

Eco-Shield®

The Eco-Shield mark indicates TCLP compliant
lamps, a smart choice for environmental responsibility.

Plug-In Lamps

Halco’s TCLP compliant lamps ensure energy
efficiency and light levels. These lamps are available in
2700K, 3000K, 3500K, 4100K and 5000K. Common
applications include wallwash units, flood lighting,
low bays and desk lamps. Our lamps offer up-to
20,000 hours average rated life and are available in
5 to 57 watts.

ENERGY STAR® Rating

High-Lumen Long

Flicker-free performance, increased optical control
and up-to 85 lumens per watt make these lamps an
economical alternative to T8 and T12 U-Bend lamps.
Offering up-to 20,000 hours average rated life, our
high-lumen lamps are TCLP compliant and are backed
by a 1-year warranty.

Self-Ballasted CFLs

Instant-start electronic ballast technology gives these
lamps reliable starts even in cold applications. Available
in a wide variety of lamp types including dimmable,
reflectors, decorative and bare spirals to meet almost
any need.

Halco’s ENERGY STAR products deliver exceptional features while generating savings for consumers.
For our most current ENERGY STAR products, please visit our literature library at www.halcolighting.
com/download.

LINEAR FLUORESCENT LAMPS

Advancing technologies and environmental focus have changed the face of Linear Fluorescent lighting. From
ultra thin and efficient to specialized applications, Halco has your lighting needs covered with an assortment of
reliable ProLume® Linear Fluorescent lamps and ballasts.

Eco-Shield®

Lamp and Ballast Systems

CEE

ProLume reduced wattage T8 lamps are perfect in
applications that require near equivalent or slightly
less light than standard 32W T8 lamps. ProLume
lamps feature a performance-enhancing tri-phosphor
coating that improves both the light quality (CRI) and
efficiency of the lamps.

The Eco-Shield mark indicates TCLP compliant lamps,
a smart choice for environmental responsibility.

Halco is proud to offer one of the largest listings of
CEE lamps in the industry, defining efficiency and
high-performance lighting products and encouraging
the use of energy-efficient products.
Participating utilities across the U.S. commonly
offer significant rebates to commercial and industrial
customers that utilize CEE qualified high performance
and reduced wattage ballasts and lamps in new
construction, replacement and retrofit projects. For
an up-to-date list of our CEE listed items, please visit
www.halcolighting.com/download.

Imagine increasing lumens per watt performance
while reducing total power consumption.

System Warranty

Halco’s Linear Fluorescent lamps are engineered to
provide optimum performance when operated by a
ProLume ballast. In fact, Halco extends the warranty
of its Linear Fluorescent lamps when installed with a
new ProLume ballast for a maximum of three years
from date of original installation. See warranty for
details at www.halcolighting.com/download.

HID LAMPS

Utilizing the latest technologies, Halco offers a broad selection of Metal Halide, High Pressure Sodium
and Mercury Vapor lamps that cover a wide range of common and specialty applications.

Ceramic Discharge Metal Halide

Halco’s Ceramic Discharge Metal Halide (CDM)
lamps offer an array of benefits including excellent
color rendering, energy efficiency and long life. They
offer up-to 16,000 hours average rated life and
feature a single piece arc tube design for a more
defined white light.

Pulse Start Metal Halide

Pulse Start lamps provide a quick re-strike, upto 110 lumens per watt and 20% higher lumen
maintenance than standard Metal Halide lamps.
ProLume Pulse Start lamps are available in 50 to
1000 watts.

Protected Metal Halide

Designed for operation in open fixtures, these
shrouded MP lamps are available in both Pulse
Start and Standard Metal Halide. The protective
quartz shroud surrounds the arc tube, providing
both safety and UV filtering.

Specialty Metal Halide

ProLume aquarium, color and safety coated Metal
Halide lamps are available in a variety of lamp types
to fit your special application needs.

High Pressure Sodium

ProLume offers a complete line of High Pressure
Sodium (HPS) lamps for general lighting applications.
These lamps are extremely energy efficient and are
a good choice for lighting large areas where color
rendering is not crucial and long life is desired.

Mercury Vapor

Mercury Vapor lamps produce an efficient white
light and are a cost effective light source for general
and security lighting. Prolume Mercury Vapor lamps
range from 50 to 1000 watts and are available in
traditional HID lamp shapes as well as A23 and R40
shapes.

HALOGEN LAMPS

Halco offers a broad selection of Halogen lamp types, wattages and bases to meet lighting needs for general,
display/accent, and retail applications. HaloXen® lamp technology utilizes a mix of Halogen and Xenon gas that
improves efficiency and lamp life over standard Halogen lamps. HaloXen® lamps provide integrated UV protection,
elevated color temperature and a crisp, white light throughout the life of the lamp.

Replacements for Legislated Halogen PAR Lamps

Halco has developed three unique options for replacing 45 to 120 watt Halogen PAR lamps affected by DOE energy
conservation standards. Our three solutions address various marketplace performance and value considerations
so you can match each customer with the right lamp:

1HaloXen

PAR Reflector Series
An economic and energy efficient
alternative to legislated PAR20,
PAR30, PAR30L and PAR38
Halogen lamps. HaloXen® PAR
Reflector 130V options are available
for customers with voltage spike
concerns.
®

2 HaloXen

Silver PAR Series
Pair a Xenon burner with a silver
reflector to improve efficacy by upto 30% over standard Halogen.
PAR30, PAR30L and PAR38 Silver
PAR lamps that offer up to 19.75
lumens per watt.

3

XIR Infrared PAR Series
Utilize an infrared capsule to
achieve up-to 30% higher lumens
per watt than standard Halogen
lamps and have an average rated
life of 3,500 hours. XIR Infrared
PAR lamps replace standard 75W
PAR30, PAR30L and PAR38 lamps.

Replacements for Legislated Incandescent A19 Lamps
PRISM® Halogen A19 lamps are the ideal replacements for Incandescent A19 lamps affected by the standards
enacted by the Energy Independence and Security Act (EISA). These lamps deliver the same light quality as
Incandescent lamps while using 28% less power. Clear and soft white Incandescent replacements are available.

INCANDESCENT LAMPS

®

Our General Service and Decorative Incandescent lamp offering is one of the most comprehensive product
assortments available from a single source. Halco’s extensive global manufacturing capabilities ensure both
selection and quality in our Incandescent lamp family.
®

®

Halco and PRISM brands each represent specific product segments targeted to fit various needs from industrial,
commercial, or residential markets. Residential products are identified with the Halco brand and are packaged
®
for retail presentation. PRISM branded products signify long life, value-added lamps for industrial/commercial
applications. With so many options, there is a Halco lamp for every need.

PRISM® Long Life Plus

Constructed using a heavy-duty staggered support C-9M filament, these 5,000 hour 130 Volt lamps provide long
life and are suitable for rough service applications. Halco offers a large assortment of lamp types and wattages
sure to meet all industrial/commercial applications.

PRISM® Ultralife

Designed using the same heavy-duty filament as our Long Life Plus lamps, these industrial/commercial
lamps utilize a krypton gas fill to maximize lamp life up-to 20,000 hours. Ideal for hard-to-reach or high ceiling
applications, UltraLife lamps are available in a variety of wattages and lamp types.

SPECIALTY LAMPS

®

Halco offers a wide variety of Specialty lamp types and lamp accessories to meet diverse application needs,
including Photo/Projection/SSTV lamps, Miniature lamps, Safety Coated lamps, Sealed Beam lamps, Socket
Adapters and Tube Guards.

Photo/Projection/SSTV

Halco offers an array of ANSI-coded Photo, Projection and SSTV lamps that are precision built to maximize light
quality, control and stability in order to meet the needs of various specialty applications.

Miniatures

Miniature lamps are designed for applications which include aircraft, auto, marine, railway indicator and truck, as
well as emergency, garden, indicator, instrument, microscope, radio and telephone indicator products.

Sealed Beam

These ANSI-coded PAR lamps are available in a number of wattages that feature beam spreads and sizes to meet
an assortment of lighting needs. Halco sealed beam lamps are manufactured to the highest quality standards and
comply with strict ANSI specifications.

COVERSHIELD LAMPS

Shatter Resistant Lighting
CoverShield®, Halco’s safety coated product line, features a comprehensive offering of shatter-resistant
lamps and coatings designed to meet a variety of application requirements. Types of coatings vary
depending on the lamp application. In high heat environments, for example, PFA is used while other
industry leading materials are applied elsewhere. The CoverShield product line includes Compact
Fluorescent, Linear Fluorescent, Incandescent, Halogen and Metal Halide lamp categories.

ELECTRONIC FLUORESCENT BALLASTS

Halco’s ProLume® Electronic Fluorescent ballasts are designed with energy efficiency, reliability, ease-of-use and reduced
maintenance costs in mind.

ProFormance® Ballasts

Halco’s exclusive ProLume ProFormance Electronic ballasts, identifiable by the “EP” product code prefix, feature high power
factor, less than 10% THD, and are available in both multi-volt and dedicated voltage models. ProLume ProFormance ballasts
are renowned for their guaranteed versatility, efficiency and minimal power loss.

Multi-Volt

Operating on a universal input voltage between 108 and 305 volts, ProLume ProFormance Multi-Volt ballasts utilize a single
power lead that doesn’t require special wiring. This feature simplifies ordering, reduces inventory costs and provides peace-ofmind that one ballast can be used in multiple applications.

Electronic Upgrades from Magnetic T12 Ballasts

Halco offers a number of electronic solutions for replacing magnetic T12 ballasts. ProLume Electronic ballasts provide more
than 20% energy savings compared to their magnetic counterparts. Furthermore, ProLume Electronic ballasts are quieter,
provide flicker-free operation and are easier to handle due to their reduced weight and size. Backed by a 5-year warranty,
ProLume Electronic Fluorescent ballasts are an efficient, convenient and long-life upgrade from traditional ballasts.

ProLume® High Efficiency T8 Ballasts

All Halco ProLume High Efficiency ballasts are NEMA Premium designated and CEE qualified high performance or reduced
wattage ballasts, signifying that they meet or exceed the stringent performance requirements set by NEMA and CEE. ProLume
High Efficiency ballasts are eligible for many utility rebates that often cover a significant portion of the product’s upfront costs.

Certification

All ProLume Electronic ballasts are certified by Underwriters Laboratories for use in the United States and are certified by either
Underwriters Laboratories or Canadian Standards Association (CSA) for use in Canada and backed by a 5-year warranty.

APP SHOT

ELECTRONIC SIGN BALLASTS

Halco’s ProLume® Electronic Sign ballasts are energy efficient, user-friendly alternatives to magnetic sign ballasts.

Energy Efficient

ProLume Electronic Sign ballasts consume up-to 25% less energy than magnetic sign ballasts. Savings are quickly realized,
particularly in applications where signs are operated for an extended period of time.

Versatile Replacement For Magnetic Sign Ballasts

Operating cooler and quieter than magnetic sign ballasts, ProLume Electronic Sign ballasts cover all signage applications
that require one to six T8/HO and T12/HO lamps that have a total length between 2 and 48 feet. They are much lighter and
have fewer wires than their magnetic counterparts, easing installation and maintenance. With their multi-volt capability (120277V), ProLume Electronic Sign ballasts address more applications with fewer SKUs than standard magnetic sign ballast
lines, reducing distributors’ inventory costs.

Parallel Lamp Operation

The parallel lamp operation ensures that if a lamp fails, the remaining lamps will continue operating, keeping the sign lit.
These instant start ballasts provide reliable starting in temperatures as low as -20°F.

Certifications

ProLume’s electronic sign ballasts are UL listed and backed by a 3-year warranty.

COMPACT FLUORESCENT BALLASTS

Halco’s ProLume® Compact Fluorescent (CFL) ballasts offer a broad assortment of options for lighting applications that require
4-pin Compact Fluorescent lamps. Look for the ProFormance (EP) mark, which identifies ProLume CFL ballasts that feature high
power factor operation and less than 10% THD.

Programmed Start

ProLume ProFormance® CFL ballasts feature programmed start circuitry, which surpasses standard rapid start technology.
Programmed start ballasts precisely heat the lamp filament and tightly control the duration of preheating before applying the
starting voltage to the lamp. The result is improved performance of both the lamp and ballast and extended life of the lamp.

Quick-Connect

Our Quick-Connect technology simplifies installation and maintenance of ProLume ProFormance CFL ballasts. Under this colorcoded system, wire installation is easy and the need to cap off unused leads is eliminated. The wire-removal tool included with
the kit allows for quick and easy wire disconnecting.

Distributor Kits

ProLume ProFormance CFL ballasts are ideal for replacement applications due to their multi-volt capability and Dual Connection
feature, which provides side and bottom lead exits utilizing Quick-Connect technology. Distributor Kits include everything that is
necessary for ballast replacement including a mounting plate, lead-wire set, wire-removal tool and mounting hardware.

End-of-Life Protection

ProLume ProFormance CFL ballasts are equipped with end-of-life protection. This technology safely removes power supplied
to the lamp during failure. After a failed lamp has been replaced, the ballast auto-resets and provides power to the new lamp.

Certifications

All ProLume Compact Fluorescent ballasts are certified by Underwriters Laboratories for use in the United States and Canada
and backed by a 5-year warranty.

ELECTRONIC HID BALLASTS

Halco’s Electronic HID (eHID) ballasts are designed to meet a variety of application needs for low wattage Metal Halide
lamps. These eHID ballasts are compact and provide distinct advantages over magnetic versions. Key benefits of Halco eHID
ballasts include enhanced light quality, increased versatility, greater savings and improved safety.

Superior Light Output

Halco eHID ballasts are microprocessor controlled, which allows for constant monitoring and regulation of wattage delivered
to the lamp. This feature, combined with a virtually flicker-free design, results in greater lumen maintenance, precise beam
control and a more uniform light appearance.

Flexible Voltage and Mounting

Our eHID ballasts are compatible with both 120 and 277 voltages and operate metal halide lamp wattages of 20W, 35/39W
and 70W. Each ballast and wattage is available with either side or bottom lead exits and mounts for versatility. In addition,
Halco’s eHID ballasts are lightweight, easy to install and reduce shipping expenses.

Savings

In addition to improved light quality, eHID ballasts provide lamps with higher efficacy and longer life compared to magnetic
ballasts. Increased efficacy through reduced ballast losses allows for less power consumption while maintaining light levels,
resulting in energy savings. Plus, longer lamp life on eHID ballasts decreases costs associated with frequent lamp replacement.

Safety Features

Our eHID ballasts provide protection against no-lamp and end of life operation. Continuous striking without a lamp, or with a
failed lamp present, could damage circuits. Halco’s eHID ballasts prevent these scenarios. Additional protection is provided
through integrated thermal and over-voltage circuits designed to shut down the ballast if operating conditions exceed those
specified for use.

Certifications

ProLume eHID Ballasts are backed with a 3-year warranty.

HID ELECTROMAGNETIC BALLASTS

ProLume® Core and Coil HID ballasts operate a wide variety of Standard and Pulse Start Metal Halide and High Pressure
Sodium lamp types.

Multi-Tap

ProLume HID ballasts provide a wide range of multi-tap ballast options. 4-Tap ballasts are offered throughout the line, while
5-Tap ballasts are available for higher wattages. Multi-tap engineering means one ballast for applications with 120V, 208V,
240V, 277V and 480V (5-tap models).

Distributor Kits

ProLume HID ballasts come in complete distributor replacement kits. Kits include an Ignitor when applicable, a Capacitor
when required, as well as mounting brackets and hardware.

Capacitors and Ignitors

For your convenience, Capacitors and Ignitors can be purchased individually. ProLume Ignitors are manufactured using only
the highest quality components. Replacement Dry Film and Oil-Filled Capacitors are also available for all ProLume ballasts.
Oil-Filled Capacitors are provided with ballasts 1000 watts and above.

Certifications

All ProLume Electromagnetic HID ballasts, Ignitors and included Capacitors are certified by Underwriters Laboratories for
use in the United States and Canada and backed with a 2-year warranty.

®

LED LAMPS
CONTENTS

main
TOC

44

How to Read a Table

45

JC Type Lamps

45

Elevator Lamps

45

Decorative Lamps

47

MR11 & MR16 Lamps

48

PAR Lamps

50

Linear Lamps

50

Sign Lamps

51

Reflector Lamps

51

Pool Bright Lamps

52

Miniature Lamps

52

C7 and C9 Lamps

52

Headlamps

53

Bulb and Base Identification

54

Symbols, Footnotes and Abbreviations

HOW TO READ A LED LAMP TABLE
LIFE

Rated at L70.

BULB

VOLTS

Designations indicate shape and size.
Illustrations can be found on page 53
and at the top of each page.

BASE

Indicates base type.
Full base descriptions and
illustrations can be found
on page 53.

Bulb

Base

Product
Number

Footnotes

Indicates the
product’s design
voltage of operation.

Abbreviated product description
can also be used for ordering.
A key to abbreviations can be
found on page 55.

Description

COLOR
TEMP.

Indicates minimum sell
quantity and smallest
shipping carton.

A term used to
describe the
color of a light
source and is
expressed in
degrees
“Kelvin” (K).

PRODUCT
CODE

Product
Code

PACKAGE
QUANTITY

MOL

Indicates
maximum
overall
length in
inches.

Color
Lumens
Temp.

Life

Pkg. Beam
MOL
Qty. Spread

Volts

CRI

10-18

82

3000

120

20000

1/40

-

1.21”

10-18

82

3000

100

40000

1/10

-

1.75”

10-18

82

3000

120

20000

1/40

-

2.01”

10-18

82

3000

100

40000

1/10

-

1.93”

JC Type Lamps
1.5 WATT
JC10

G4

BA15s

80693

$ 1,4,5,6

JC10/1WW/LED

80776

$ 1,4,6,10

JC10/1WW/LED2

80692

$ N,1,4,5,6

80810

 $ N,1,4,6,10

IP65 Rated

JC10/1WW/BA15S/LED
JC10/1WW/BA15S/LED2

IP65 Rated

FOOTNOTES &
SYMBOLS

Related footnotes can
be found on page 54.

WATTS

Indicates the
power consumed
by the lamp during
operation.

PRODUCT
NUMBER

Use this number when
placing an order.

LUMENS
DESCRIPTION

Bulb finish and other
important information.

CRI

Represents
average
light output.

An international scale from
0 to 100 that indicates the
relative color rendering value
of a light source. The color
rendering index expresses the
degree to which colors will
look “natural” under a given
light source.

TOC

BEAM
SPREAD

Indicates the
beam angle or
beam spread
of a bulb,
measured in
degrees.

LED LAMPS
Solid State Lighting

R12
BA15d

Bulb

Base

R12
BA15s

Product
Number

B10

CA10

Footnotes

B11

B11

Product
Code

JC35
G4

JC20
G4

Description

JC10
G4

JC20
BA15s

JC
BA15S
IP65

JC10
BA15s

Volts

CRI

Color
Lumens
Temp.

10-18

82

3000

10-18

82

10-18

JC
G4
IP65

Life

Pkg.
Qty.

Beam
MOL
Spread

120

20000

1/40

-

1.21”

3000

100

40000

1/10

-

1.75”

82

3000

120

20000

1/40

-

1.70”

JC Type Lamps
1.5 WATT
JC10

G4

80693

$ 1,4,5,6

JC10/1WW/LED

80776

$ 1,4,6,10

JC10/1WW/LED2

BA15s 80692

$ N,1,4,5,6

80810

 $ N,1,4,6,10

80782

$ 1,4,5,6

IP65 Rated

JC10/1WW/BA15S/LED
JC10/1WW/BA15S/LED2

IP65 Rated

10-18

82

3000

100

40000

1/10

-

1.93”

JC20/2AMB/LED

Amber

10-18

-

-

-

20000

1/40

-

1.81”

1.8 WATT
JC20

G4

80780

$ 1,4,5,6

JC20/2BLU/LED

Blue

10-18

-

-

-

20000

1/40

-

1.81”

80779

$ 1,4,5,6

JC20/2GRN/LED

Green

10-18

-

-

-

20000

1/40

-

1.81”

80781

$ 1,4,5,6

JC20/2RED/LED

Red

10-18

-

-

-

20000

1/40

-

1.81”

80690

$ 1,4,5,6

JC20/2WW/LED

10-18

82

3000

200

20000

1/40

-

1.81”

80815

$ 1,4,5,6

JC20/2NW/LED

10-18

72

5000

230

20000

1/40

-

1.81”

BA15s 80691

$ N,1,4,5,6

JC20/2WW/BA15S/LED

10-18

82

3000

200

20000

1/40

-

2.01”

2.4 WATT
JC20

G4

2.5 WATT
JC20

G4

80774

$ 1,4,6,10

BA15s 80775

$ N,1,4,6,10

JC20/2WW/LED2

IP65 Rated

10-18

82

3000

140

40000

1/10

-

1.75”

JC20/2WW/BA15S/LED2

IP65 Rated

10-18

82

3000

140

40000

1/10

-

2.25”

10-18

82

3000

450

20000

1/30

-

2.03”

4.5 WATT
JC35

G4

80830

 $ 1,4,5,6

JC35/4WW/LED

Elevator Lamps
2.6 WATT
R12

BA15d 80756

$ N,1,4,5,7

GBF/3WW/LED

10-18

82

2700

145

40000

1/10

31°

2.52”

BA15s 80701

$ N,1,4,5,7

1383/3WW/LED

10-18

82

2700

145

40000

1/10

31°

2.52”

Decorative Lamps
1 WATT
B10

CA10

Cand.

Cand.

80172

 3,4,5,7,8

B10CL1/827/LED

Clear

120

82

2700

25

25000

1/25

-

3.77”

80173

 3,4,5,7,8

B10CL1/724/LED

Clear

120

72

2400

20

25000

1/25

-

3.77”

80174

 3,4,5,7,8

CA10CL1/827/LED

Clear

120

82

2700

25

25000

1/25

-

4.00”

80175

 3,4,5,7,8

CA10CL1/724/LED

Clear

120

72

2400

20

25000

1/25

-

4.00”

80014

$ N,2,4,5,7,15

B11/2WW/LED

Non-Dimmable

120

82

3000

65

40000

1/10

-

3.94”

80094

$ N,4,5,7,8,15

B11CL3/827/LED

Cream Finish

120

82

2700

180

25000

1/10

-

3.78”

80789

$ N,4,5,7,8,15

B11CL3/827/BR/LED

Brass Finish

120

82

2700

180

25000

1/10

-

3.78”

80790

$ N,4,5,7,8,15

B11CL3/827/CHR/LED

Chrome Finish

120

82

2700

180

25000

1/10

-

3.78”

2 WATT
B11

Cand.

3 WATT
B11

Cand.

LED lamp symbols, footnotes and abbreviations are located on page 54-55.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 45

LED LAMPS
Solid State Lighting

A19

Bulb

Base

Product
Number

Footnotes

Product
Code

A19
GU24

A19

Description

Volts

CRI

Color
Lumens
Temp.

B11
E26

B11

G25

Life

Pkg.
Qty.

Beam
MOL
Spread

Decorative Lamps continued
4 WATT
A19

Med.

80149  $ N,3,4,5,7,8,15

A19FR4/827/LED

A-Shape

120

82

2700

250

40000

1/6

-

4.25”

80150  $ N,3,4,5,7,8,15

A19FR4/830/LED

A-Shape

120

82

3000

260

40000

1/6

-

4.25”

Cand.

80820  $ N,3,4,5,7,8,15

B11CL5/827/LED

Cream Finish

120

82

2700

300

25000

1/10

-

3.78”

Med.

80168  $ N,3,4,5,7,8,15

B11CL5/827/E26/LED

Cream Finish

120

82

2700

300

25000

1/10

-

3.78”

Med.

80020  $ N,3,4,5,7,8,15

A19FR5/830/LED

A-Shape

120

82

3000

260

25000

1/6

-

4.25”

GU24

80151  $ N,3,4,5,7,8,15

A19FR6/827/GU24/LED

A-Shape

120

82

2700

450

40000

1/6

-

4.25”

Med.

80152  $ N,3,4,5,7,8,15

A19FR6/827/LED

A-Shape

120

82

2700

450

40000

1/6

-

4.25”

80153  $ N,3,4,5,7,8,15

A19FR6/830/LED

A-Shape

120

82

3000

470

40000

1/6

-

4.25”

80817  $ N,3,4,5,7,8,15

A19FR6/840/LED

A-Shape

120

82

4000

490

40000

1/6

-

4.25”

80816  $ N,3,4,5,7,8,15

A19FR6/850/LED

A-Shape

120

82

5000

510

40000

1/6

-

4.25”

5 WATT
B11

A19

6 WATT
A19

8 WATT
A19

Med.

80022

$ N,3,4,5,7,8,15

A19FR8/830/LED

A-Shape

120

82

3000

450

35000

1/6

-

4.25”

G25

Med.

80018

$ N,3,4,5,7,8,15

G25/8WW/LED

Globe

120

82

3000

430

25000

1/6

-

4.25”

80146  $ N,3,4,5,7,8,15

A19FR10/827/LED

A-Shape

120

82

2700

800

25000

1/6

-

4.41”

80132  $ N,3,4,5,7,8,15

A19FR10/830/LED

A-Shape

120

82

3000

830

40000

1/6

-

4.41”

10 WATT
A19

Med.

LED lamp symbols, footnotes and abbreviations are located on pages 54-55.

46

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

LED LAMPS
Solid State Lighting

MR16
GU10

MR11

Bulb

Base

Product
Number

MR16

Footnotes

MR11
BA15d

Product
Code

Description

Volts CRI

Color
Lumens CBCP
Temp.

Life

Pkg. Beam
MOL
Qty. Spread

MR11 and MR16 Lamps
2.2 WATT
MR11

GU4

80703

$ 1,4,5,6,7,8

MR11/2NW/FL/LED

Flood

10-18

72

5000

150

420

40000

1/10

30°

1.42”

80705

$ 1,4,5,6,7,8

MR11/2WW/FL/LED

Flood

10-18

82

2700

110

330

40000

1/10

30°

1.42”

80704

$ 1,4,5,6,7,8

MR11/2WW/NFL/LED

Narrow Flood

10-18

82

2700

110

860

40000

1/10

18°

1.42”

GU5.3 80807

 $ 1,4,5,6,7,8

MR16SP10/827/LED

Spot

10-15

82

2700

140

1180

40000

1/10

15°

2.02”

80806

 $ 1,4,5,6,7,8

MR16NFL10/827/LED

Narrow Flood

10-15

82

2700

150

480

40000

1/10

25°

2.02”

80801

 $ 1,4,5,6,7,8

MR16FL10/827/LED

Flood

10-15

82

2700

150

300

40000

1/10

40°

2.02”

80808

 $ 1,4,5,6,7,8

MR16WFL/827/LED

Wide Flood

10-15

82

2700

140

170

40000

1/10

50°

2.02”

80813

 $ 1,4,5,6,7,8

MR16FL10/750/LED

Flood

10-15

72

5000

160

360

40000

1/10

40°

2.02”

80000

 $ 1,4,5,6,7,8

MR16/3WW/FL/LED2

Flood

12

82

3000

150

360

40000

1/10

38°

1.97”

GU5.3 80709

$ 1,4,5,6,7,8

MR16/3WW/FL/LED

Flood

10-18

82

2700

150

380

40000

1/10

34°

2.20”

MR11FTD/827/LED

Flood

10-15

82

2700

300

1135

40000

1/10

30°

1.89”

3 WATT
MR16

3.3 WATT
MR16

3.5 WATT
MR11

BA15d 80169

MR16

GU10

 $ 1,4,5,6,7,8

80742

$ 3,4,5,7,8

MR16/4NW/FL/GU10/LED Flood

120

72

5000

190

490

40000

1/10

29°

2.17”

80743

$ 3,4,5,7,8

MR16/4WW/FL/GU10/LED Flood

120

82

2700

140

370

40000

1/10

30°

2.17”

80819

 $ 3,4,5,7,8

MR16FL4/830/GU10/LED

Flood

120

82

3000

220

480

40000

1/10

40°

2.17”

GU5.3 80728

$ 1,4,5,6,7

MR16/5RGB/FL/LED

Color Changing
Red, Green, Blue

10-18

-

-

-

-

40000

1/10

31°

2.17”

RGB/REMOTE

Remote Control for Color Changing Lamps

4 WATT
MR16

GU10

80649

4.5 WATT
MR16

GU5.3 80795

 $ 1,4,5,6,7,8

MR16ESX/827/LED

Spot

10-15

82

2700

200

1260

40000

1/10

15°

2.02”

80793

 $ 1,4,5,6,7,8

MR16BBF/827/LED

Narrow Flood

10-15

82

2700

220

750

40000

1/10

25°

2.02”

80792

 $ 1,4,5,6,7,8

MR16BAB/827/LED

Flood

10-15

82

2700

220

400

40000

1/10

40°

2.02”

80794

 $ 1,4,5,6,7,8

MR16WFL20/827/LED

Wide Flood

10-15

82

2700

200

240

40000

1/10

60°

2.02”

80811

 $ 1,4,5,6,7,8

MR16BAB/750/LED

Flood

10-15

72

5000

250

480

40000

1/10

40°

2.02”

80702

$ 1,4,5,6,7,8

MR16/3M4WW/FL/LED

Flood

10-18

82

2700

220

560

40000

1/10

34°

2.20”

80724

$ 1,4,5,6,7

MR16/3M4AMB/NFL/LED

Narrow Flood Amber 10-18

-

-

-

-

40000

1/10

22°

2.20”

80727

$ 1,4,5,6,7

MR16/3M4BLU/NFL/LED

Narrow Flood Blue

10-18

-

-

-

-

40000

1/10

22°

2.20”

80726

$ 1,4,5,6,7

MR16/3M4GRN/NFL/LED

Narrow Flood Green 10-18

-

-

-

-

40000

1/10

22°

2.20”

80725

$ 1,4,5,6,7

MR16/3M4RED/NFL/LED

Narrow Flood Red

-

-

-

-

40000

1/10

22°

2.20”

10-18

LED lamp symbols, footnotes and abbreviations are located on page 54-55.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 47

LED LAMPS
Solid State Lighting

MR16

Bulb

Base

Product
Number

Footnotes

Product
Code

MR16
GU10

PAR16

PAR36
IP67

PAR16

Description

Volts CRI

Color
Lumens CBCP
Temp.

Life

Pkg. Beam
MOL
Qty. Spread

MR16 Lamps continued
6 WATT
MR16 GU5.3

GU10

80805

 $ 1,4,5,6,7,8

MR16FRB/827/LED

Spot

10-15

82

2700

320

1650

40000

1/10

18°

2.02”

80804

 $ 1,4,5,6,7,8

MR16FRA/827/LED

Narrow Flood

10-15

82

2700

350

1500

40000

1/10

25°

2.02”

80802

 $ 1,4,5,6,7,8

MR16FMW/827/LED

Flood

10-15

82

2700

350

600

40000

1/10

40°

2.02”

80809

 $ 1,4,5,6,7,8

MR16WFL35/827/LED

Wide Flood

10-15

82

2700

320

250

40000

1/10

60°

2.02”

80814

 $ 1,4,5,6,7,8

MR16FMW/750/LED

Flood

10-15

72

5000

410

720

40000

1/10

40°

2.02”

80016

 $ 1,4,5,6,7,8

MR16FL6/830/LED

Flood

10-15

82

3000

370

620

40000

1/10

40°

2.13”

80084

 $ 1,4,5,6,7,8

MR16FL6/830/GU10/LED

Flood

120

82

3000

370

620

40000

1/10

40°

3.11”

80167

 $ 1,4,5,6,7,8

M16FL7/830/GU10/LED

Flood

120

82

3000

520

1100

25000

1/10

40°

2.17”

80799

 $ 1,4,5,6,7,8

MR16EXT/827/LED

Spot

10-15

82

2700

450

2000

40000

1/10

18°

2.02”

80800

 $ 1,4,5,6,7,8

MR16EXZ/827/LED

Narrow Flood

10-15

82

2700

500

1700

40000

1/10

25°

2.02”

80798

 $ 1,4,5,6,7,8

MR16EXN/827/LED

Flood

10-15

82

2700

500

850

40000

1/10

40°

2.02”

80803

 $ 1,4,5,6,7,8

MR16FNV/827/LED

Wide Flood

10-15

82

2700

450

390

40000

1/10

60°

2.02”

 $ 1,4,5,6,7,8

MR16EXN/750/LED

Flood

10-15

72

5000

580

1020

40000

1/10

40°

2.02”

7 WATT
MR16 GU10

8 WATT
MR16 GU5.3

80812

PAR Lamps
3.3 WATT
PAR16

Med.

80748

$ N,3,4,5,7,8

PAR16/3NW/NFL/LED

Narrow Flood

120

72

5000

160

460

40000

1/6

28°

2.99”

80749

$ N,3,4,5,7,8

PAR16/3WW/NFL/LED

Narrow Flood

120

82

2700

145

370

40000

1/6

27°

2.99”

80732

$ N,2,4,5,7

PAR16/4AMB/NFL/LED

Narrow Flood Amber 120

-

-

-

-

40000

1/6

22°

2.99”

80729

$ N,2,4,5,7

PAR16/4RED/NFL/LED

Narrow Flood Red

120

-

-

-

-

40000

1/6

22°

2.99”

80731

$ N,2,4,5,7

PAR16/4GRN/NFL/LED

Narrow Flood Green

120

-

-

-

-

40000

1/6

22°

2.99”

80078

$ 3,4,5,8,14,15

PAR16FL6/827/LED

Flood

120

82

2700

360

670

40000

1/10

40°

3.27”

80080

$ 3,4,5,8,14,15

PAR16FL6/830/LED

Flood

120

82

3000

370

690

40000

1/10

40°

3.27”

80082

$ 3,4,5,8,14,15

PAR16FL6/850/LED

Flood

120

82

5000

400

750

40000

1/10

40°

3.27”

80698

$ N,3,4,5,7,8

PAR16/6NW/FL/LED2

Flood

120

72

5000

385

610

40000

1/10

40°

3.35”

80697

$ N,3,4,5,7,8

PAR16/6WW/FL/LED2

Flood

120

82

2700

310

530

40000

1/10

40°

3.35”

80720

$ N,3,4,5,7,8

PAR16/6WW/SP/LED2

Spot

120

82

2700

310

2370

40000

1/10

14°

3.35”

80106

$ 1,4,7,13,16

PAR36/6WW/SP/LED

Spot IP67 Rated

10-15

82

2700

260

1820

40000

1/6

15°

2.40”

80768

$ 1,4,7,13,16

PAR36/6WW/WFL/LED2

Wide Flood IP67
Rated

10-15

82

2700

260

680

40000

1/6

32°

2.40”

3.6 WATT
PAR16 Med.

4.5 WATT
PAR16 Med.

6 WATT
PAR16 Med.

6.5 WATT
PAR36 MP
Term

48

TOC

LED lamp symbols, footnotes and abbreviations are located on pages 54-55.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

LED LAMPS
Solid State Lighting

RGB
PAR20

Bulb

Base

PAR20

Product
Number

Footnotes

PAR20

PAR30
Short Neck

Product
Code

PAR30

Description

PAR36
IP67

PAR36

Volts CRI

Color
Lumens CBCP
Temp.

Life

Pkg. Beam
MOL
Qty. Spread

PAR Lamps continued
7.2 WATT
PAR20 Med.

PAR20/7AMB/NFL/LED

Narrow Flood Amber 120

$ 3,4,5,8,14,15

PAR20FL8/830/LED

Flood

80070

$ 3,4,5,8,14,15

PAR20NFL8/827/LED

80024

$ 3,4,5,8,14,15

80074
80076

80736

$ N,2,4,5,7

-

-

-

-

40000

1/6

25°

3.43”

80072

120

82

3000

380

600

40000

1/6

40°

3.43”

Narrow Flood

120

82

2700

365

1250

40000

1/6

25°

3.43”

PAR20NFL8/830/LED

Narrow Flood

120

82

3000

380

1300

25000

1/6

25°

3.43”

$ 3,4,5,8,14,15

PAR20NFL8/840/LED

Narrow Flood

120

82

4000

395

1350

40000

1/6

25°

3.43”

$ 3,4,5,8,14,15

PAR20NFL8/850/LED

Narrow Flood

120

82

5000

410

1400

40000

1/6

25°

3.43”

PAR20/8RGB/NFL/LED

Color Changing
Red, Green, Blue

120

-

-

-

-

40000

1/6

25°

3.50”

PAR20/8RGB/REMOTE

Remote Control for Color Changing Lamps

8 WATT
PAR20 Med.

80638

$ N,2,4,5,7

80649

10 WATT
PAR36 MP
Term

80783

$ 1,4,7,13,16

PAR36/10WW/SP/LED

Spot IP67 Rated

10-15

82

2700

420

4200

40000

1/6

15°

2.40”

80769

$ 1,4,7,13,16

PAR36/10WW/WFL/LED2

Wide Flood,
Amber IP67 Rated

10-15

82

2700

420

920

40000

1/6

32°

2.40”

80784

$ 1,4,7,13,16

PAR36/10AMB/WFL/LED

Wide Flood,
Amber IP67 Rated

10-15

-

-

-

-

40000

1/6

32°

2.40”

80786

$ 1,4,7,13,16

PAR36/10BLU/WFL/LED

Wide Flood,
Blue IP67 Rated

10-15

-

-

-

-

40000

1/6

32°

2.40”

80785

$ 1,4,7,13,16

PAR36/10GRN/WFL/LED

Wide Flood,
Green IP67 Rated

10-15

-

-

-

-

40000

1/6

32°

2.40”

80787

$ 1,4,7,13,16

PAR36/10RED/WFL/LED

Wide Flood,
Red IP67 Rated

10-15

-

-

-

-

40000

1/6

32°

2.40”

80066

$ 3,4,5,8,14,15

PAR30FL13/827/LED

Flood

120

82

2700

680

1250

40000

1/6

40°

4.49”

80026

$ 3,4,5,8,14,15

PAR30FL13/830/LED

Flood

120

82

3000

700

1280

25000

1/6

40°

4.49”

80068

$ 3,4,5,8,14,15

PAR30FL13/840/LED

Flood

120

82

4000

730

1340

40000

1/6

40°

4.49”

80030

$ 3,4,5,8,14,15

PAR30FL13/850/LED

Flood

120

82

5000

760

1360

40000

1/6

40°

4.49”

80096

$ 3,4,5,8,14,15

PAR30NFL13/827/LED

Narrow Flood

120

82

2700

680

2910

40000

1/6

25°

4.49”

80028

$ 3,4,5,8,14,15

PAR30NFL13/830/LED

Narrow Flood

120

82

3000

700

3000

40000

1/6

25°

4.49”

80038

$ 3,4,5,8,14,15

PAR30NFL13/850/LED

Narrow Flood

120

82

5000

760

3250

40000

1/6

25°

4.49”

80102

$ 3,4,5,8,14,15

PAR30SP13/827/LED

Spot

120

82

2700

680

4900

40000

1/6

15°

4.49”

80098

$ 3,4,5,8,14,15

PAR30SP13/830/LED

Spot

120

82

3000

700

5100

40000

1/6

15°

4.49”

80100

$ 3,4,5,8,14,15

PAR30SP13/850/LED

Spot

120

82

5000

760

5500

40000

1/6

15°

4.49”

80165  $ 1,4,5,6,7,8,17

PAR36FL14/827/LED

Flood

12

82

2700

870

1830

40000

1/6

32°

2.40”

80142

$ 3,4,8,14,15

PAR30FL15S/827/LED

Flood

120

82

2700

770

1500

40000

1/6

40°

3.75”

80138

$ 3,4,8,14,15

PAR30FL15S/830/LED

Flood

120

82

3000

800

1600

25000

1/6

40°

3.75”

13 WATT
PAR30 Med.

14 WATT
PAR36 MP
Term

15 WATT
PAR30 Med.
Short

LED lamp symbols, footnotes and abbreviations are located on page 54-55.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 49

LED LAMPS
Solid State Lighting

S14 Clear

Bulb

Base

Product
Number

Footnotes

Product
Code

T8 Med
Bi-Pin

S14

Description

Volts CRI

PAR38

Color
Lumens CBCP
Temp.

PAR36

Life

Pkg. Beam
MOL
Qty. Spread

PAR Lamps continued
16 WATT
PAR38 Med.

80040

$ 3,4,5,8,14,15 PAR38FL16/827/LED

Flood

120

82

2700

920

1700

40000

1/6

40°

5.00”

80032

$ 3,4,5,8,14,15 PAR38FL16/830/LED

Flood

120

82

3000

950

1770

25000

1/6

40°

5.00”

80044

$ 3,4,5,8,14,15 PAR38FL16/840/LED

Flood

120

82

4000

990

1850

40000

1/6

40°

5.00”

80036

$ 3,4,5,8,14,15 PAR38FL16/850/LED

Flood

120

82

5000

1020

1930

40000

1/6

40°

5.00”

80034

$ 3,4,5,8,14,15 PAR38NFL16/830/LED

Narrow Flood

120

82

3000

950

4000

40000

1/6

25°

5.00”

80042

$ 3,4,5,8,14,15 PAR38SP16/830/LED

Spot

120

82

3000

950

6700

40000

1/6

15°

5.00”

18 WATT
PAR36 MP
Term

80788

$ 1,4,7,13,16 PAR36/18WW/SP/LED2

Spot IP67 Rated

10-15

82

2700

720

3000

40000

1/6

20°

2.40”

80770

$ 1,4,7,13,16 PAR36/18WW/WFL/LED2

Wide Flood IP67
Rated

10-15

82

2700

720

1800

40000

1/6

32°

2.40”

120

82

2700

1150

1970

40000

1/6

40°

5.00”

20 WATT
PAR38 Med.

80050

$ 3,4,5,8,14,15 PAR38FL20/827/LED

Flood

80056

$ 3,4,5,8,14,15 PAR38FL20/830/LED

Flood

120

82

3000

1200

2050

25000

1/6

40°

5.00”

80058

$ 3,4,5,8,14,15 PAR38FL20/840/LED

Flood

120

82

4000

1250

2150

40000

1/6

40°

5.00”

80064

$ 3,4,5,8,14,15 PAR38FL20/850/LED

Flood

120

82

5000

1300

2200

40000

1/6

40°

5.00”

80048

$ 3,4,5,8,14,15 PAR38NFL20/827/LED

Narrow Flood

120

82

2700

1150

4850

40000

1/6

25°

5.00”

80054

$ 3,4,5,8,14,15 PAR38NFL20/830/LED

Narrow Flood

120

82

3000

1200

5000

40000

1/6

25°

5.00”

80062

$ 3,4,5,8,14,15 PAR38NFL20/850/LED

Narrow Flood

120

82

5000

1300

5400

40000

1/6

25°

5.00”

80046

$ 3,4,5,8,14,15 PAR38SP20/827/LED

Spot

120

82

2700

1150

7700

40000

1/6

15°

5.00”

80052

$ 3,4,5,8,14,15 PAR38SP20/830/LED

Spot

120

82

3000

1200

8100

40000

1/6

15°

5.00”

80060

$ 3,4,5,8,14,15 PAR38SP20/850/LED

Spot

120

82

5000

1300

8700

40000

1/6

15°

5.00”

Linear Lamps
18 WATT
T8

Bi-Pin

80170

 $ 2,4,5 T8FR18/840/LED

Linear T8 Tube

120277

82

4000

1800

-

40000

1/12

120°

48”

80171

 $ 2,4,5 T8FR18/850/LED

Linear T8 Tube

120277

82

5000

1800

-

40000

1/12

120°

48”

Sign Lamps
1.4 WATT
S14

Med.

80517

 3,4,7,8,10 S14RED1C/LED

Red IP65 Rated

120

-

-

-

-

40000

1/25

-

3.35”

80518

 3,4,7,8,10 S14BLU1C/LED

Blue IP65 Rated

120

-

-

-

-

40000

1/25

-

3.35”

80519

 3,4,7,8,10 S14GRN1C/LED

Green IP65 Rated

120

-

-

-

-

40000

1/25

-

3.35”

80520

 3,4,7,8,10 S14YEL1C/LED

Yellow IP65 Rated

120

-

-

-

-

40000

1/25

-

3.35”

80521

 3,4,7,8,10 S14WH1C/LED

White IP65 Rated

120

-

-

-

-

40000

1/25

-

3.35”

80522

 3,4,7,8,10 S14CL1/827/LED

Clear IP65 Rated

120

82

2700

35

-

40000

1/25

-

3.35”

LED lamp symbols, footnotes and abbreviations are located on pages 54-55.

50

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

LED LAMPS
Solid State Lighting

BR40

Bulb

Base

BR30

Product
Number

BR30

Footnotes

BR30
GU24

Product
Code

R20

Description

Volts

CRI

Color
Lumens
Temp.

Life

Pkg.
Qty.

Beam
Spread

MOL

Reflector Lamps
5 WATT
R20

Med.

80108

 $ 3,4,5,8,14,15 R20FL5/830/LED

Flood

120

82

3000

310

40000

1/6

-

3.94”

80110

 $ 3,4,5,8,14,15 R20FL5/850/LED

Flood

120

82

5000

335

40000

1/6

-

3.94”

80818

 $ 3,4,5,8,14,15 R20FL8/827/LED

Flood

120

82

2700

500

25000

1/6

-

3.94”

80112

 $ 3,4,5,8,14,15 R20FL8/830/LED

Flood

120

82

3000

520

25000

1/6

-

3.94”

80114

 $ 3,4,5,8,14,15 R20FL8/850/LED

Flood

120

82

5000

560

40000

1/6

-

3.94”

BR30 GU24

80158

 $ 3,4,5,8,14,15 BR30FL9/827/GU24/LED

Flood

120

82

2700

650

40000

1/6

-

5.12”

Med.

80159

 $ 3,4,5,8,14,15 BR30FL9/827/LED

Flood

120

82

2700

650

25000

1/6

-

5.12”

80160

 $ 3,4,5,8,14,15 BR30FL9/830/LED

Flood

120

82

3000

670

40000

1/6

-

5.12”

80161

 $ 3,4,5,8,14,15 BR30FL9/840/LED

Flood

120

82

4000

700

40000

1/6

-

5.12”

80162

 $ 3,4,5,8,14,15 BR30FL9/850/LED

Flood

120

82

5000

730

40000

1/6

-

5.12”

80166

 $ 3,4,5,8,14,15 BR0FL9/PNK/LED

Flood Pink

120

-

-

-

40000

1/6

-

5.12”

80086

 $ 3,4,5,8,14,15 BR30FL11/827/LED

Flood

120

82

2700

730

25000

1/6

-

5.12”

80088

 $ 3,4,5,8,14,15 BR30FL11/830/LED

Flood

120

82

3000

750

25000

1/6

-

5.12”

80090

 $ 3,4,5,8,14,15 BR30FL11/840/LED

Flood

120

82

4000

780

40000

1/6

-

5.12”

80092

 $ 3,4,5,8,14,15 BR30FL11/850/LED

Flood

120

82

5000

810

40000

1/6

-

5.12”

80116

 $ 3,4,5,8,14,15 BR40FL13/827/LED

Flood

120

82

2700

850

25000

1/6

-

6.46”

80118

 $ 3,4,5,8,14,15 BR40FL13/830/LED

Flood

120

82

3000

880

25000

1/6

-

6.46”

80120

 $ 3,4,5,8,14,15 BR40FL13/840/LED

Flood

120

82

4000

920

40000

1/6

-

6.46”

80122

 $ 3,4,5,8,14,15 BR40FL13/850/LED

Flood

120

82

5000

950

40000

1/6

-

6.46”

Flood

120

82

3000

860

25000

1/6

-

5.28”

8 WATT
R20

Med.

9 WATT

11 WATT
BR30 Med.

13 WATT
BR40 Med.

15 WATT
BR30 Med.

$ 3,4,5,8,14,15 BR30/15WW/FL/LED

80778

18 WATT
BR40 Med.

80124

 $ 3,4,5,8,14,15 BR40FL18/827/LED

Flood

120

82

2700

1200

40000

1/6

-

6.46”

80126

 $ 3,4,5,8,14,15 BR40FL18/830/LED

Flood

120

82

3000

1230

25000

1/6

-

6.46”

80128

 $ 3,4,5,8,14,15 BR40FL18/840/LED

Flood

120

82

4000

1280

40000

1/6

-

6.46”

80130

 $ 3,4,5,8,14,15 BR40FL18/850/LED

Flood

120

82

5000

1320

40000

1/6

-

6.46”

Pool Bright
8 WATT
R20

Med.

80822

 $ 3,4,5,11 R20FL8/POOL/12V/LED

Pool Bright

12

82

6500

1000*

40000

6/24

-

3.94”

80821

 $ 3,4,5,11 R20FL8/POOL/LED

Pool Bright

120

82

6500

1000*

40000

6/24

-

3.94”

*Scotopic Lumens

LED lamp symbols, footnotes and abbreviations are located on page 54-55.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 51

LED LAMPS
Solid State Lighting
BR40
R40

Bulb

Product
Number

Base

Product
Code

Footnotes

Description

C7

C9

Volts

CRI

Color
Lumens
Temp.

3155

Life

Pkg.
Qty.

912

Beam
MOL
Spread

Pool Bright continued
18 WATT
R40

Med.

80136

 $ 3,4,5,11

R40FL18/POOL/12V/LED

Pool Bright

12

82

6500

3150*

40000

6/24

-

6.46”

80134

 $ 3,4,5,11

R40FL18/POOL/LED

Pool Bright

120

82

6500

3150*

40000

6/24

-

6.46”

10-18

82

3000

50

20000

1/50

-

1.18”

10-18

82

3000

140

40000

1/10

-

2.40”

Miniatures
1 WATT
Mini
Wedge

80791

 $ 1,4,5,6

80777

 $ 1,4,5,6,10

912/1WW/LED

2.5 WATT
Plastic
Wedge

Bulb

Product
Number

Base

3155/2WW/LED

Footnotes

IP65 Rated

Product
Code

Description

Volts

Color
Temp.

Life

Pkg.
Qty.

MOL

C7 and C9 Lamps
0.96 WATT
C7

Cand.

C9

Int.

Watts

80510

$ N,2,4,7,10

C7NW/FC/LED

Clear Faceted

120

6000

60000

10/200

1.30”

80516

$ N,2,4,7,10

C7WW/FC/LED

Clear Faceted

120

2700

60000

10/200

1.30”

80508

$ N,2,4,7,10

C7BLU/FC/LED

Blue Faceted

120

-

60000

10/200

1.30”

80509

$ N,2,4,7,10

C7GRN/FC/LED

Green Faceted

120

-

60000

10/200

1.30”

80506

$ N,2,4,7,10

C7RED/FC/LED

Red Faceted

120

-

60000

10/200

1.30”

80507

$ N,2,4,7,10

C7YEL/FC/LED

Yellow Faceted

120

-

60000

10/200

1.30”

80515

$ N,2,4,7,10

C9CL/FC/LED

Clear Faceted

120

6000

60000

10/200

1.60”

80513

$ N,2,4,7,10

C9BLU/FC/LED

Blue Faceted

120

-

60000

10/200

1.60”

80514

$ N,2,4,7,10

C9GRN/FC/LED

Green Faceted

120

-

60000

10/200

1.60”

80511

$ N,2,4,7,10

C9RED/FC/LED

Red Faceted

120

-

60000

10/200

1.60”

80512

$ N,2,4,7,10

C9YEL/FC/LED

Yellow Faceted

120

-

60000

10/200

1.60”

Product
Number

Footnotes

Product
Code

Description

Color
Temp.

Pkg.
Qty.

HL/18LED

18 LED Water Resistant Headlamp - Requires 3 AAA Batteries

6000

50/200

Headlamp
0.75

80920

12

*Scotopic Lumens
LED lamp symbols, footnotes and abbreviations are located on page 54-55.

52

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

LED LAMPS
Bulb and Base Identification Guide
Bulb Shapes

PAR16

PAR16
(Colors Only)

PAR36
IP67

T8 Medium
Bi-Pin

S14

PAR20
(RGB Only)

MR11
BA15d

PAR36

A19

S14 Clear

PAR20

MR11

CA10

A19
GU24

A19

Globe

PAR20

BR40/R40

PAR30
Short Neck

MR16
GU10

B10

B11

B11

Candelabra
E12

Intermediate
E17

Plastic
Wedge
Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Wedge

JC20

JC10

R12
BA15d

JC20
BA15s

BR30

BR30
GU24

R20

SC Bayonet
BA15s

GU10

DC Bayonet
BA15d

BR30

G4

JC35

PAR38

C9

C7

MR16

Base Types

Medium
E26

PAR30

Medium
Bi-Pin
G13

GU5.3

JC10
BA15s

Plastic
Wedge

R12
BA15s

JC G4
IP65

JC
BA15s
IP65

Mini
Wedge

MP-Term

GU24

TOC 53

LED LAMPS
Symbols, Footnotes and Abbreviations
SYMBOLS


New product introduced within the past year.

N

Nickel-plated brass base.

$

Energy saving product.

X

Product will be discontinued when inventory is depleted.

FOOTNOTES
This device is intended for use on Class 2 circuits only. Use only on low voltage circuits with output
ranges identified in specifications. These lamps may be dimmed using analog dimmers and magnetic
1 transformers. May not be compatible with all dimmers and/or transformers and should be tested in
application for compatibility prior to full installations on circuits using such devices. Not for use on timing
devices, photo sensors or occupancy sensors.
2

Non-Dimmable 120V lamps should only be used on 120V circuits. Not for use on dimmers, timing devices,
photo sensors or occupancy sensors.

Dimmable 120V lamps should only be used on 120V circuits. Lamps are designed for use with an analog
dimmer and these products may not be compatible with all dimming devices. Lamps should be tested in
3
the application prior to full installations on circuits using such devices. Not for use on timing devices, photosensors, digital dimmers or occupancy sensors. Ensure minimum dimmer load is met for best performance.
Caution: Risk of electric shock. Never disassemble or modify the bulb, no user serviceable parts inside.
To avoid burns, do not touch the bulb during operation and allow to cool completely after switching off.
4 This device is not intended for use in emergency exit fixtures. This device complies with Part 18 of the FCC
rules. This product may cause interference with other devices. If interference occurs, change the location
of the products involved.
5 Do not use where directly exposed to water.
6 Approved for use in sealed metal landscape fixtures.
7 Do not use in totally enclosed fixtures or IC or ICAT rated recessed cans.
8 Dimmable lamps dim down to 5%, but are limited by the dimming device range.
9 Base down operation only.
10

IP65 Rated – this lamp is rated for use outdoors where exposed directly to water from rain or irrigation.
The lamp is not submersible, not for enclosed fixtures.

11

This product is designed to allow operation in metal construction pool fixtures and is
allowed in this type of enclosed fixture.

12 Batteries not included.
13

IP67 Rated - This lamp is rated for use outdoors where exposed directly to water and protected
from the effects of temporary immersion in water to depth between 5.9” (15cm) and 39.37” (1m).

14

Not for use in totally enclosed fixtures.
Acceptable for use in insulated contact airtight (ICAT) rated fixtures

15 Lamp is UL approved for damp locations.
16 Rated for outdoor use only.
17 Rated for indoor use only.
54

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

LED LAMPS
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
724 Refers to a color temperature of 2400K and 72CRI.
750 Refers to a color temperature of 5000K and 72CRI.
827 Refers to a color temperature of 2700K and 82CRI.
830 Refers to a color temperature of 3000K and 82CRI.
840 Refers to a color temperature of 4000K and 82CRI.
850 Refers to a color temperature of 5000K and 82CRI.
AMB Code abbreviation for an Amber lamp.
BA15S Code abbreviation for a lamp with a BA15s base.
BLU Code abbreviation for a Blue lamp.
BR Code abbreviation for a lamp with a Brass base.
C Code abbreviation for lamp with Ceramic Paint Color.
CHR Code abbreviation for a lamp with a Chrome base.
CL Code abbreviation for a Clear lamp.
E26 Code abbreviation for a lamp with a E26 base.
FL Code abbreviation for Flood lamps.
FR Code abbreviation for a Frosted lamp.
GRN Code abbreviation for a Green lamp.
GU10 Code abbreviation for a lamp with a GU10 base.
GU24 Code abbreviation for a lamp with a GU24 base.
NFL Code abbreviation for Narrow Flood lamps.
NW Code abbreviation for a lamp with a color temperature of 5000K.
POOL Code abbreviation for a Pool Bright lamp.
RED Code abbreviation for a Red lamp.
RGB Code abbreviation for a Color Changing Red, Green and Blue lamp.
S Code abbreviation for short neck PAR30 lamp.
SP Code abbreviation for Spot lamps.
WFL Code abbreviation for Wide Flood lamps.
WH Code abbreviation for a White lamp.
WW Code abbreviation for a lamp with a color temperature of 2700K.
YEL Code abbreviation for a Yellow lamp.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 55

®

COMPACT FLUORESCENT LAMPS
CONTENTS
58 How to Read a Table
59 Bare Spiral Lamps
63 Reflector Lamps
64 Decorative Lamps
65 Single Tube 2-Pin Lamps
65 Single Tube 4-Pin Lamps
65 Double Tube 2-Pin Lamps
66 Double Tube 4-Pin Electronic Lamps
66 Triple Tube 4-Pin Electronic Lamps
68 High Lumen Long 4-Pin Lamps
68 Flat Quad 4-Pin Electronic Lamps
69 Bulb and Base Identification
70 Cross Reference Guide
73 Symbols, Footnotes and Abbreviations

HOW TO READ A COMPACT FLUORESCENT
LAMP TABLE
PACKAGE QUANTITY

Indicates minimum sell quantity
and smallest shipping carton.

BULB

Designations indicate shape and size.
Illustrations can be found on page 69
and at the top of each page.

Abbreviated product description
can also be used for ordering.
A key to abbreviations can be
found on page 74.

Indicates base type.
Full base descriptions
and illustrations can
be found on page 69.

Base

11 WATT
PAR20

R20

Med.

GU24

Product
Number

Footnotes

Indicates the
power consumed
by the lamp during
operation.

Average rated life
expressed in hours.

MOL

Indicates
maximum
overall length
in inches.

Product
Code

Description

Pkg.
Qty.

Color
Temp.

CRI

Lumens

Avg.
Life

MOL

MOD

CFL Reflector
46005

$ 2,4,8

CFL11/27/PAR20

Warm White Flood

6/24

2700

82

380

10000

3.86”

2.48”

46006

$ 2,4,8

CFL11/35/PAR20

White Flood

6/24

3500

82

380

10000

3.86”

2.48”

46007

$ 2,4,8

CFL11/41/PAR20

Cool White Flood

6/24

4100

82

380

10000

3.86”

2.48”

46008

$ 2,4,8

CFL11/50/PAR20

Natural White Flood

6/24

5000

82

380

10000

3.86”

2.48”

46542

$ 2,4,8

CFL11/27/R20/GU24

Warm White Flood

6/24

2700

82

340

10000

4.02”

2.50”

FOOTNOTES &
SYMBOLS
WATTS

AVERAGE
LIFE

A term used to
describe the
color of a light
source and is
expressed in
degrees
“Kelvin” (K).

PRODUCT CODE

BASE

Bulb

COLOR
TEMP.

Related footnotes can
be found on page 73.

DESCRIPTION

Bulb finish and other
important information.

LUMENS
Represents
average
light output.

PRODUCT
NUMBER

Use this number when
placing an order.

MOD
CRI

An international
scale from 0 to 100
that indicates the
relative color rendering
value of a light source.
The color rendering
index expresses the
degree to which colors
will look “natural” under
a given light source.

TOC

Indicates
maximum
overall
diameter
in inches.

COMPACT FLUORESCENT LAMPS
Self-Ballasted
®

Spiral
Bulb

Base

Product
Number

Footnotes

Product
Code

Description

Pkg.
Qty.

Color
Temp.

CRI

Lumens

Avg.
Life

MOL

MOD

CFL Bare Spiral
5 WATT
T2

Cand.

Med.

45011

$,1,3,4

CFL5/27/E12

Warm White

10/50

2700

82

250

10000

3.50”

1.38”

45015

X $ 1,3,4

CFL5/35/E12

White

10/50

3500

82

250

10000

3.50”

1.38”

45017

X $ 1,3,4

CFL5/41/E12

Cool White

10/50

4100

82

250

10000

3.50”

1.38”

45019

X $ 1,3,4

CFL5/50/E12

Natural White

10/50

5000

82

250

10000

3.50”

1.38”

45010

$ 1,3,4

CFL5/27

Warm White

10/50

2700

82

250

10000

3.56”

1.38”

46600

X $ 1,3,4

CFL5/27/FS

Warm White Full Spiral

10/50

2700

82

300

12000

2.98”

1.93”

45014

X $ 1,3,4

CFL5/35

White

10/50

3500

82

250

10000

3.56”

1.38”

45016

$ 1,3,4

CFL5/41

Cool White

10/50

4100

82

250

10000

3.56”

1.38”

45018

$ 1,3,4

CFL5/50

Natural White

10/50

5000

82

250

10000

3.56”

1.38”

45031

$ 1,3,4

CFL9/27/E12

Warm White

10/50

2700

82

500

10000

4.00”

1.57”

9 WATT
T2

Cand.

Med.

45035

X $ 1,3,4

CFL9/35/E12

White

10/50

3500

82

500

10000

4.00”

1.57”

45037

X $ 1,3,4

CFL9/41/E12

Cool White

10/50

4100

82

500

10000

4.00”

1.57”

45039

X $ 1,3,4

CFL9/50/E12

Natural White

10/50

5000

82

500

10000

4.00”

1.57”

45030

$ 1,3,4

CFL9/27

Warm White

10/50

2700

82

500

10000

4.06”

1.57”

46605

X $ 1,3,4

CFL9/27/FS

Warm White Full Spiral

10/50

2700

82

500

12000

3.41”

1.93”

45034

$ 1,3,4

CFL9/35	

White

10/50

3500

82

500

10000

4.06”

1.57”

45036

$ 1,3,4

CFL9/41

Cool White

10/50

4100

82

500

10000

4.06”

1.57”

45038

X $ 1,3,4

CFL9/50

Natural White

10/50

5000

82

500

10000

4.06”

1.57”

109240

$ 1,3,4

CFL11/27

Warm White

10/50

2700

82

700

12000

4.29”

1.85”

109242

$ 1,3,4

CFL11/41

Cool White

10/50

4100

82

700

12000

4.29”

1.85”

109244

$ 1,3,4

CFL11/50

Natural White

10/50

5000

82

700

12000

4.29”

1.85”

109224

$ 1,3,4

CFL11/BLU

Blue

10/50

-

-

-

8000

4.29”

1.85”

109226

X $ 1,3,4

CFL11/GRN

Green

10/50

-

-

-

8000

4.29”

1.85”

109220

$ 1,3,4

CFL11/RED

Red

10/50

-

-

-

8000

4.29”

1.85”

109222

$ 1,3,4

CFL11/YEL

Yellow

10/50

-

-

-

8000

4.29”

1.85”

45052

$ 1,3,4

CFL13/27/T2/E12

Warm White

10/50

2700

82

900

10000

4.19”

1.81”

45055

$ 1,3,4

CFL13/35/T2/E12

White

10/50

3500

82

900

10000

4.19”

1.81”

45057

$ 1,3,4

CFL13/41/T2/E12

Cool White

10/50

4100

82

850

10000

4.19”

1.81”

45059

$ 1,3,4

CFL13/50/T2/E12

Natural White

10/50

5000

82

900

10000

4.19”

1.81”

45049

$ 1,3,4

CFL13/27/T2

Warm White

10/50

2700

82

900

12000

4.19”

1.81”

45071

$ 1,3,4

CFL13/27/T2/4PK

Warm White 4-Pack

20/60

2700

82

900

12000

4.19”

1.81”

11 WATT
T3

Med.

13 WATT
T2

Cand.

Med.

Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 59

COMPACT FLUORESCENT LAMPS
Self-Ballasted
®

®

Spiral
GU24

Bulb

Product
Number

Base

Footnotes

Product
Code

Description

Spiral

Pkg.
Qty.

Color
Temp.

CRI

Lumens

Avg.
Life

MOL

MOD

CFL Bare Spiral continued
13 WATT continued
T2

Med.

GU24

T3

Med.

GU24

46610

$ 1,3,4

CFL13/27/FS

Warm White Full Spiral

10/50

2700

82

840

12000

3.84”

1.93”

45054

$ 1,3,4

CFL13/35/T2

White

10/50

3500

82

900

10000

4.19”

1.81”

45056

$ 1,3,4

CFL13/41/T2

Cool White

10/50

4100

82

850

10000

4.19”

1.81”

45073

$ 1,3,4

CFL13/41/T2/4PK

Cool White 4-Pack

20/60

4100

82

850

10000

4.19”

1.81”

45058

$ 1,3,4

CFL13/50/T2

Natural White

10/50

5000

82

900

10000

4.19”

1.81”

46506

$ 1,3,4

CFL13/27/GU24

Warm White

10/50

2700

82

800

10000

3.63”

1.81”

46525

$ 1,3,4

CFL13/35/GU24

White

10/50

3500

82

800

10000

3.63”

1.81”

46526

$ 1,3,4

CFL13/41/GU24

Cool White

10/50

4100

82

800

10000

3.63”

1.81”

46527

$ 1,3,4

CFL13/50/GU24

Natural White

10/50

5000

82

800

10000

3.63”

1.81”

45101

$ 1,3,4

CFL13/27

Warm White

10/50

2700

82

900

10000

4.41”

1.97”

45103

$ 1,3,4

CFL13/35

White

10/50

3500

82

900

10000

4.41”

1.97”

45104

$ 1,3,4

CFL13/41

Cool White

10/50

4100

82

900

10000

4.41”

1.97”

45105

$ 1,3,4

CFL13/50

Natural White

10/50

5000

82

900

10000

4.41”

1.97”

45107

$ 1,3,4

CFL13/65

Daylight

10/50

6500

82

850

10000

4.41”

1.97”

46544

$ 3,5,6

CFL13/27/GU24/DIM

Warm White Dimmable

10/50

2700

82

800

10000

4.00”

1.81”

45720

$ 4,5,8

CFL25/27/3WAY

Warm White 3-Way

10/50

2700

82

8000

6.13”

2.36”

45721

$ 4,5,8

CFL25/41/3WAY

Cool White 3-Way

10/50

4100

82

8000

6.13”

2.36”

109252

$ 4,5,8

CFL15/27

Warm White

10/50

2700

82

950

10000

4.94”

1.85”

109330

$ 4,5,8

CFL15/35

White

10/50

3500

82

950

10000

4.94”

1.85”

109261

$ 4,5,8

CFL15/41

Cool White

10/50

4100

82

950

10000

4.94”

1.85”

109272

$ 4,5,8

CFL15/50

Natural White

10/50

5000

82

950

10000

4.94”

1.85”

109270

$ 4,5,8

CFL15/BLB

Blacklight-Blue

1/20

-

-

-

12000

4.94”

1.85”

109288

$ 4,5,8

CFL15/YEL

Yellow

1/50

-

-

-

12000

4.94”

1.85”

46330

$ 1,3,6

CFL15/27/DIM

Warm White Dimmable

10/50

2700

82

900

10000

4.92”

1.81”

45062

$ 1,3,4

CFL18/27/T2

Warm White

10/50

2700

82

1100

10000

4.56”

2.13”

45064

$ 1,3,4

CFL18/35/T2

White

10/50

3500

82

1100

10000

4.56”

2.13”

13/20/25 WATT
T3

Med.

15 WATT
T3

Med.

900/
1200/
1600
900/
1200/
1600

18 WATT
T2

Med.

GU24

60

TOC

45065

$ 1,3,4

CFL18/41/T2

Cool White

10/50

4100

82

1100

10000

4.56”

2.13”

45066

$ 1,3,4

CFL18/50/T2

Natural White

10/50

5000

82

1100

10000

4.56”

2.13”

46512

$ 1,3,4

CFL18/27/GU24

Warm White

10/50

2700

82

1200

10000

3.90”

2.13”

46519

$ 1,3,4

CFL18/35/GU24

White

10/50

3500

82

1200

10000

3.90”

2.13”

46520

$ 1,3,4

CFL18/41/GU24

Cool White

10/50

4100

82

1200

10000

3.90”

2.13”

46521

$ 1,3,4

CFL18/50/GU24

Natural White

10/50

5000

82

1200

10000

3.90”

2.13”

Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

COMPACT FLUORESCENT LAMPS
Self-Ballasted
®

®

Spiral
GU24

Spiral

Bulb

Base

Product
Number

Footnotes

Product
Code

Description

Pkg.
Qty.

Color
Temp.

CRI

Lumens

Avg.
Life

MOL

MOD

CFL Bare Spiral continued
18 WATT continued
T3

Med.

GU24

45120

$ 1,3,4

CFL18/27

Warm White

10/50

2700

82

1200

12000

5.24”

2.05”

45122

$ 1,3,4

CFL18/35

White

10/50

3500

82

1200

12000

5.24”

2.05”

45123

$ 1,3,4

CFL18/41

Cool White

10/50

4100

82

1200

12000

5.24”

2.05”

45124

$ 1,3,4

CFL18/50

Natural White

10/50

5000

82

1200

12000

5.24”

2.05”

46546

$ 3,5,6

CFL18/27/GU24/DIM

Warm White Dimmable

10/50

2700

82

1200

10000

4.40””

2.05”

109254

$ 1,3,4

CFL20/27

Warm White

10/50

2700

82

1250

12000

5.25”

2.05”

109263

$ 1,3,4

CFL20/41

Cool White

10/50

4100

82

1250

12000

5.25”

2.05”

109274

$ 1,3,4

CFL20/50

Natural White

10/50

5000

82

1250

12000

5.25”

2.05”

45075

$ 1,3,4

CFL23/27/T2

Warm White

10/50

2700

82

1600

10000

4.92”

2.13”

20 WATT
T3

Med.

23 WATT
T2

Med.

GU24

T3

Med.

GU24

46620

X $ 1,3,4

CFL23/27/FS

Warm White

10/50

2700

82

1600

12000

4.65”

2.28”

45077

$ 1,3,4

CFL23/41/T2

Cool White

10/50

4100

82

1600

10000

4.92”

2.13”

45079

$ 1,3,4

CFL23/50/T2

Natural White

10/50

5000

82

1600

10000

4.92”

2.13”

46518

$ 1,3,4

CFL23/27/GU24

Warm White

10/50

2700

82

1600

10000

4.41”

2.13”

46522

$ 1,3,4

CFL23/35/GU24

White

10/50

3500

82

1600

10000

4.41”

2.13”

46523

$ 1,3,4

CFL23/41/GU24

Cool White

10/50

4100

82

1600

10000

4.41”

2.13”

46524

$ 1,3,4

CFL23/50/GU24

Natural White

10/50

5000

82

1600

10000

4.41”

2.13”

45250

$ 1,3,4

CFL23/27

Warm White

10/50

2700

82

1600

10000

5.04”

2.05”

46334

$ 4.5,6,8

CFL23/27/DIM

Warm White Dimmable

10/50

2700

82

1600

10000

5.59”

2.13”

45252

$ 1,3,4

CFL23/35

White

10/50

3500

82

1600

10000

5.04”

2.05”

45253

$ 1,3,4

CFL23/41

Cool White

10/50

4100

82

1600

10000

5.04”

2.05”

45254

$ 1,3,4

CFL23/50

Natural White

10/50

5000

82

1600

10000

5.04”

2.05”

46548

$ 3,5,6

CFL23/27/GU24/DIM

Warm White Dimmable

10/50

2700

82

1600

10000

4.73”

2.36”

46528

$ 1,3,4

CFL26/27/GU24

Warm White

10/50

2700

82

1750

10000

5.20”

2.13”

46531

$ 1,3,4

CFL26/35/GU24

White

10/50

3500

82

1750

10000

5.20”

2.13”

26 WATT
T3

GU24

46529

$ 1,3,4

CFL26/41/GU24

Cool White

10/50

4100

82

1750

10000

5.20”

2.13”

46530

$ 1,3,4

CFL26/50/GU24

Natural White

10/50

5000

82

1750

10000

5.20”

2.13”

109310

$ 3,4,5

CFL27/27

Warm White

10/50

2700

82

1900

10000

5.44”

2.44”

45255

$ 3,4,5

CFL27/35

White

10/50

3500

82

1850

10000

5.44”

2.44”

109312

$ 3,4,5

CFL27/41

Cool White

10/50

4100

82

1850

10000

5.44”

2.44”

109314

$ 3,4,5

CFL27/50

Natural White

10/50

5000

82

1750

10000

5.44”

2.44”

27 WATT
T3

Med.

Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 61

COMPACT FLUORESCENT LAMPS
Self-Ballasted
®

T6 EX39

Bulb

Product
Number

Base

Footnotes

Product
Code

Spiral

Description

Pkg.
Qty.

Color
Temp.

CRI

Lumens

Avg.
Life

MOL

MOD

CFL Bare Spiral continued
32 WATT
T3

Med.

109316

$ 4,5,8

CFL32/27

Warm White

10/50

2700

82

2250

8000

5.56”

2.76”

109318

$ 4,5,8

CFL32/41

Cool White

10/50

4100

82

2200

8000

5.56”

2.76”

109306

$ 4,5,8

CFL32/50

Natural White

10/50

5000

82

2200

8000

5.56”

2.76”

109328

$ 4,5,8

CFL42/27

Warm White

6/24

2700

82

2900

12000

7.06”

2.83”

109336

$ 4,5,8

CFL42/41

Cool White

6/24

4100

82

2800

12000

7.06”

2.83”

109338

$ 4,5,8

CFL42/50

Natural White

6/24

5000

82

2800

12000

7.06”

2.83”

45600

$ 4,5,7

CFL65/27

Warm White

1/6

2700

82

4300

10000

9.50”

3.54”

45604

$ 4,5,7

CFL65/50

Natural White

1/6

5000

82

4300

10000

9.50”

3.54”

Med.

45606

$ 4,5,7

CFL85/27

Warm White

1/6

2700

82

5700

10000

10.00” 4.02”

45610

$ 4,5,7

CFL85/50

Natural White

1/6

5000

82

5700

10000

10.00” 4.02”

Mog.

45500

$ 4,5,7

CFL85/50/E39

Natural White

1/6

5000

82

5700

10000

10.50” 4.02”

45618

$ 4,5,7

CFL105/50

Natural White

1/6

5000

82

7000

10000

10.75” 4.02”

45502

$ 4,5,7,9

CFL105/50/277V

Natural White 277V

1/6

5000

82

7000

10000

10.75” 4.02”

45614

$ 4,5,7

CFL105/50/E39

Natural White

1/6

5000

82

7000

10000

11.25” 4.02”

45504

$ 4,5,7,9

CFL105/50/E39/277V

Natural White 277V

1/6

5000

82

7000

10000

11.25” 4.02”

47000

$ 4,5,7

CFL150/50/EX39

Natural White

1/6

5000

82

8800

10000

13.03” 4.72”

47001

$ 4,5,7

CFL180/50/EX39

Natural White

1/6

5000

82

11100

10000

14.33” 4.72”

42 WATT
T3

Med.

65 WATT
T5

Med.

85 WATT
T5

105 WATT
T5

Med.

Mog.

150 WATT
T6

EX39

180 WATT
T6

EX39

Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.

62

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

COMPACT FLUORESCENT LAMPS
Self-Ballasted
®

®

®
®

®

PAR38

Bulb

Base

Product
Number

PAR30

Footnotes

R30
R40

BR38

R20

PAR20

Product
Code

Description

Pkg.
Qty.

Color
Temp.

CRI

Lumens

Avg.
Life

MOL

MOD

CFL Reflector
11 WATT
PAR20

R20

Med.

GU24

46005

$ 2,4,8

CFL11/27/PAR20

Warm White Flood

6/24

2700

82

380

10000

3.86”

2.48”

46006

$ 2,4,8

CFL11/35/PAR20

White Flood

6/24

3500

82

380

10000

3.86”

2.48”

46007

$ 2,4,8

CFL11/41/PAR20

Cool White Flood

6/24

4100

82

380

10000

3.86”

2.48”

46008

$ 2,4,8

CFL11/50/PAR20

Natural White Flood

6/24

5000

82

380

10000

3.86”

2.48”

46542

$ 2,4,8

CFL11/27/R20/GU24

Warm White Flood

6/24

2700

82

340

10000

4.02”

2.50”

46011

$ 4,5,8

CFL14/30/R20

Soft White Flood

6/24

3000

82

500

8000

4.94”

2.52”

46014

$ 4,5,8

CFL14/50/R20

Natural White Flood

6/24

5000

82

500

8000

4.94”

2.52”

46550

$ 2,6,8

CFL15/27/PAR30/DIM

Warm White Dimmable Flood

6/24

2700

82

700

10000

4.60”

3.74”

46001

$ 2,4,8

CFL15/27/PAR30

Warm White Flood

6/24

2700

82

750

10000

4.60”

3.74”

14 WATT
R20

Med.

15 WATT
PAR30

R30

Med.

Med.

GU24

46002

$ 2,4,8

CFL15/35/PAR30

White Flood

6/24

3500

82

750

10000

4.60”

3.74”

46003

$ 2,4,8

CFL15/41/PAR30

Cool White Flood

6/24

4100

82

750

10000

4.60”

3.74”

46004

$ 2,4,8

CFL15/50/PAR30

Natural White Flood

6/24

5000

82

750

10000

4.60”

3.74”

46328

$ 5,6,8

CFL15/27/R30/DIM

Warm White Dimmable Flood

6/24

2700

82

680

8000

6.01”

3.74”

109056

X $ 1,4

CFL15/BLU/R30

Blue Flood

6/24

-

82

720

8000

5.10”

3.78”

109058

X $ 1,4

CFL15/GRN/R30

Green Flood

6/24

-

82

720

8000

5.10”

3.78”

109054

X $ 1,4

CFL15/PNK/R30

Pink Flood

6/24

-

82

720

8000

5.10”

3.78”

109062

X $ 1,4

CFL15/YEL/R30

Yellow Flood

6/24

-

82

720

8000

5.10”

3.78”

46538

$ 1,4,8

CFL15/27/R30/GU24

Warm White

6/24

2700

82

750

10000

4.76”

3.74”

46101

$ 4,5,8

CFL16/30/R30/ES

Soft White, Energy Saver

6/24

3000

82

750

10000

5.60”

3.78”

46104

$ 4,5,8

CFL16/41/R30

Cool White Flood

6/24

4100

82

750

10000

5.60”

3.78”

46105

$ 4,5,8

CFL16/50/R30

Natural White Flood

6/24

5000

82

750

10000

5.60”

3.78”

16 WATT
R30

Med.

23 WATT
BR38

Med.

109216

$ 2,4,8

CFL23/30/BR38

Soft White Flood

6/24

3000

82

1300

10000

6.40”

4.72”

PAR38

Med.

46201

$ 2,4,8

CFL23/27/PAR38

Warm White Flood

6/24

2700

82

1100

10000

5.06”

4.76”

46202

$ 2,4,8

CFL23/35/PAR38

White Flood

6/24

3500

82

1100

10000

5.06”

4.76”

R40

Med.

46203

$ 2,4,8

CFL23/41/PAR38

Cool White Flood

6/24

4100

82

1100

10000

5.06”

4.76”

46204

$ 2,4,8

CFL23/50/PAR38

Natural White Flood

6/24

5000

82

1100

10000

5.06”

4.76”

46329

$ 5,6,8

CFL23/27/R40/DIM

Warm White Dimmable Flood

6/24

2700

82

1090

10000

6.97”

5.00”

46210

$ 4,5,8

CFL23/27/R40

Warm White Flood

6/24

2700

82

1090

10000

6.50”

5.00”

109286

$ 4,5,8

CFL23/30/R40

Soft White Flood

6/24

3000

82

1090

10000

6.50”

5.00”

46206

$ 4,5,8

CFL23/50/R40

Natural White Flood

6/24

5000

82

1090

10000

6.50”

5.00”

46208

$ 4,5,8

CFL23/PB/R40

Pool Bright Flood

6/24

6500

82

1000*

10000

6.50”

5.00”

*Scotopic Lumens

Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 63

COMPACT FLUORESCENT LAMPS
Self-Ballasted
®

®

B13

Bulb

Product
Number

Base

Footnotes

Product
Code

A16
A19
A20

®

®

T20

G25
G28
G30

Description

Pkg.
Qty.

Color
Temp.

CRI

Lumens

Avg.
Life

MOL

MOD

CFL Decorative
5 WATT
A16

B13

Med.

45730

X $ 1,3,4

CFL5/27/A16

Warm White

10/50

2700

82

250

8000

4.07”

2.13”

45732

X $ 1,3,4

CFL5/41/A16

Cool White

10/50

4100

82

250

8000

4.07”

2.13”

Med.

45761

X $ 1,4,8

CFL5/30/B13

Soft White

10/50

3000

82

200

8000

4.57”

1.57”

Cand.

45762

X $ 1,4,8

CFL5/30/B13/E12

Soft White

10/50

3000

82

200

8000

3.86”

1.57”

9 WATT
A16

Med.

45734

$ 1,3,4

CFL9/27/A16

Warm White

10/50

2700

82

470

8000

4.50”

2.20”

B13

Med.

45763

$ 1,4,8

CFL9/30/B13

Soft White

10/50

3000

82

470

8000

4.92”

1.61”

Cand.

45764

$ 1,4,8

CFL9/30/B13/E12

Soft White

10/50

3000

82

470

8000

4.43”

1.61”

Med.

45703

 $ 1,3,4

CFL9/27/G25/ES

Warm White

6/24

2700

82

500

10000

4.33”

3.11”

45705

$ 1,3,4

CFL9/50/G25

Natural White

6/24

5000

82

500

10000

4.33”

3.11”

G25

14 WATT
A19

T20

Med.

Med.

45738

$ 1,3,4

CFL14/27/A19

Warm White

10/50

2700

82

800

10000

4.63”

2.28”

45739

$ 1,3,4

CFL14/35/A19

White

10/50

3500

82

800

10000

4.63”

2.28”

45740

$ 1,3,4

CFL14/41/A19

Cool White

10/50

4100

82

800

10000

4.63”

2.28”

45741

$ 1,3,4

CFL14/50/A19

Natural White

10/50

5000

82

800

10000

4.63”

2.28”

45755

X $ 4,5,8

CFL14/27/T20

Warm White

6/24

2700

82

800

8000

5.44”

2.48”

45758

$ 4,5,8

CFL14/50/T20

Natural White

6/24

5000

82

800

8000

5.44”

2.48”

15 WATT
A19

GU24

46540

X $ 4,5,8

CFL15/27/A19/GU24

Warm White

6/24

2700

82

800

10000

4.82”

2.64”

G25

GU24

46536

X $ 1,4,8

CFL15/27/G25/GU24

Warm White

6/24

2700

82

750

10000

4.80”

3.31”

G28

Med.

45713

$ 1,3,4

CFL15/27/G28

Warm White

6/24

2700

82

850

10000

4.73”

3.73”

45717

$ 1,3,4

CFL15/50/G28

Natural White

6/24

5000

82

850

10000

4.73”

3.73”

45725

$ 4,5,8

CFL16/27/G30

Warm White

6/24

2700

82

900

10000

5.07”

3.70”

46533

$ 4,5,8

CFL16/50/G30

Natural White

6/24

5000

82

900

10000

5.07”

3.70”

45743

$ 1,4,8

CFL20/27/A20

Warm White

6/24

2700

82

1100

8000

5.56”

2.80”

16 WATT
G30

Med.

20 WATT
A20

Med.

Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.

64

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

COMPACT FLUORESCENT LAMPS
Plug-In
Single Tube
2-Pin

Bulb

Base

Single Tube
4-Pin

Product
Number

Double Tube
2-Pin

Footnotes

Product
Code

Single Tube 2-Pin
5 WATT
T4

G23

Description

Pkg.
Qty.

Color
Temp.

CRI

Lumens

Avg.
Life

MOL

MOD

Eco-Shield®

109100

$ 10,11

PL5S/27/ECO

Warm White

1/50

2700

82

250

12000

4.25”

-

109102

$ 10,11

PL5S/41/ECO

Cool White

1/50

4100

82

250

12000

4.25”

-

7 WATT
T4

G23

109106

$ 11

PL7S/27/ECO

Warm White

1/50

2700

82

400

12000

5.43”

-

109107

$ 11

PL7S/35/ECO

White

1/50

3500

82

400

12000

5.43”

-

109108

$ 11

PL7S/41/ECO

Cool White

1/50

4100

82

400

12000

5.43”

-

109112

$ 11

PL9S/27/ECO

Warm White

1/50

2700

82

600

12000

6.61”

-

109144

$ 11

PL9S/35/ECO

White

1/50

3500

82

600

12000

6.61”

-

109116

$ 11

PL9S/41/ECO

Cool White

1/50

4100

82

600

12000

6.61”

-

109118

$ 11

PL9S/50/ECO

Natural White

1/50

5000

82

600

12000

6.61”

-

9 WATT
T4

G23

13 WATT
T4

GX23

109126

$ 11

PL13S/27/ECO

Warm White

1/50

2700

82

825

12000

7.20”

-

109128

$ 11

PL13S/35/ECO

White

1/50

3500

82

825

12000

7.20”

-

109130

$ 11

PL13S/41/ECO

Cool White

1/50

4100

82

825

12000

7.20”

-

109132

$ 11

PL13S/50/ECO

Natural White

1/50

5000

82

825

12000

7.20”

-

Single Tube 4-Pin
13 WATT
T4

2GX7

109134

$ 12,13

PL13S/E/27/ECO

Warm White

1/50

2700

82

825

12000

6.30”

-

109136

$ 12,13

PL13S/E/35/ECO

White

1/50

3500

82

825

12000

6.30”

-

109138

$ 12,13

PL13S/E/41/ECO

Cool White

1/50

4100

82

825

12000

6.30”

-

109140

$ 12,13

PL13S/E/50/ECO

Natural White

1/50

5000

82

825

12000

6.30”

-

Double Tube 2-Pin
9 WATT
T4

G23-2

Eco-Shield®

Eco-Shield®

109110

$ 11

PL9D/27/ECO

Warm White

1/50

2700

82

525

12000

4.25”

-

109120

$ 11

PL9D/41/ECO

Cool White

1/50

4100

82

525

12000

4.25”

-

109146

$ 11

PL13D/27/ECO

Warm White

1/50

2700

82

900

12000

4.65”

-

109148

$ 11

PL13D/35/ECO

White

1/50

3500

82

900

12000

4.65”

-

109150

$ 11

PL13D/41/ECO

Cool White

1/50

4100

82

900

12000

4.65”

-

109149

$ 11

PL13D/50/ECO

Natural White

1/50

5000

82

900

12000

4.65”

-

109152

$ 11

PL18D/27/ECO

Warm White

1/50

2700

82

1200

12000

6.02”

-

13 WATT
T4

GX23-2

18 WATT
T4

G24d-2

109154

$ 11

PL18D/35/ECO

White

1/50

3500

82

1200

12000

6.02”

-

109156

$ 11

PL18D/41/ECO

Cool White

1/50

4100

82

1200

12000

6.02”

-

109159

X $ 11

PL18D/50/ECO

Natural White

1/50

5000

82

1200

12000

6.02”

-

Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 65

COMPACT FLUORESCENT LAMPS
Plug-In
Double Tube
2-Pin/4-Pin

Bulb

Product
Number

Base

Footnotes

Product
Code

Triple Tube
4-Pin

Description

Pkg.
Qty.

Color
Temp.

CRI

Lumens

Avg.
Life

MOL

MOD

Double Tube 2-Pin continued
22 WATT
T5

GX32d-2

109862

$ 11

PL22D/28

Warm White 15mm Cluster

1/50

2800

82

1200

10000

6.15”

-

109864

$ 11

PL22D/50

Natural White 15mm Cluster

1/50

5000

82

1200

10000

6.15”

-

26 WATT
T5

G24d-3

109158

$ 11

PL26D/27/ECO

Warm White

1/50

2700

82

1800

12000

6.77”

-

109160

$ 11

PL26D/35/ECO

White

1/50

3500

82

1800

12000

6.77”

-

109162

$ 11

PL26D/41/ECO

Cool White

1/50

4100

82

1800

12000

6.77”

-

109163

$ 11

PL26D/50/ECO

Natural White

1/50

5000

82

1800

12000

6.77”

-

109870

$ 11

PL28D/28

Warm White 15mm Cluster

1/50

2800

82

1800

12000

6.60”

-

109868

$ 11

PL28D/50

Natural White 15mm Cluster

1/50

5000

82

1800

12000

6.60”

-

1/50

2700

82

900

15000

5.16”

-

28 WATT
T5

GX32d-3

Double Tube 4-Pin Electronic
13 WATT
T4

G24q-1

109037

$ 12,13

PL13D/E/27/ECO

Eco-Shield®
Warm White

109035

$ 12,13

PL13D/E/30/ECO

Soft White

1/50

3000

82

900

15000

5.16”

-

109038

$ 12,13

PL13D/E/35/ECO

White

1/50

3500

82

900

15000

5.16”

-

109039

$ 12,13

PL13D/E/41/ECO

Cool White

1/50

4100

82

900

15000

5.16”

-

109122

$ 12,13

PL13D/E/50/ECO

Natural White

1/50

5000

82

900

15000

5.16”

-

109010

$ 12,13

PL18D/E/27/ECO

Warm White

1/50

2700

82

1200

15000

5.75”

-

109012

$ 12,13

PL18D/E/35/ECO

White

1/50

3500

82

1200

15000

5.75”

-

109013

$ 12,13

PL18D/E/41/ECO

Cool White

1/50

4100

82

1200

15000

5.75”

-

109074

$ 12,13

PL18D/E/50/ECO

Natural White

1/50

5000

82

1200

15000

5.75”

-

109090

$ 12,13

PL26D/E/27/ECO

Warm White

1/50

2700

82

1800

15000

6.57”

-

109092

$ 12,13

PL26D/E/35/ECO

White

1/50

3500

82

1800

15000

6.57”

-

109094

$ 12,13

PL26D/E/41/ECO

Cool White

1/50

4100

82

1800

15000

6.57”

-

109096

$ 12,13

PL26D/E/50/ECO

Natural White

1/50

5000

82

1800

15000

6.57”

-

18 WATT
T4

G24q-2

26 WATT
T4

G24q-3

Triple Tube 4-Pin Electronic
18 WATT
T4

GX24q-2

Eco-Shield®

44800

$ 12,13

PL18T/E/27/ECO

Warm White

1/50

2700

82

1200

15000

4.57”

-

44801

$ 12,13

PL18T/E/35/ECO

White

1/50

3500

82

1200

15000

4.57”

-

44803

$ 12,13

PL18T/E/41/ECO

Cool White

1/50

4100

82

1200

15000

4.57”

-

44804

X $ 12,13

PL18T/E/50/ECO

Natural White

1/50

5000

82

1200

15000

4.57”

-

Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.

66

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

COMPACT FLUORESCENT LAMPS
Plug-In
Triple Tube
4-Pin

Bulb

Base

26 WATT
T4

GX24q-3

Product
Number

Footnotes

Product
Code

Triple Tube 4-Pin Electronic

Description

Pkg.
Qty.

Color
Temp.

CRI

Lumens

Avg.
Life

MOL

MOD

Eco-Shield® continued

109020

$ 12,13

PL26T/E/27/ECO

Warm White

1/50

2700

82

1800

15000

5.28”

-

109022

$ 12,13

PL26T/E/35/ECO

White

1/50

3500

82

1800

15000

5.28”

-

109024

$ 12,13

PL26T/E/41/ECO

Cool White

1/50

4100

82

1800

15000

5.28”

-

109076

$ 12,13

PL26T/E/50/ECO

Natural White

1/50

5000

82

1800

15000

5.28”

-

109026

$ 12,13

PL32T/E/27/ECO

Warm White

1/50

2700

82

2400

15000

5.79”

-

109028

$ 12,13

PL32T/E/35/ECO

White

1/50

3500

82

2400

15000

5.79”

-

109030

$ 12,13

PL32T/E/41/ECO

Cool White

1/50

4100

82

2400

15000

5.79”

-

109070

$ 12,13

PL32T/E/50/ECO

Natural White

1/50

5000

82

2400

15000

5.79”

-

109032

$ 12,13

PL42T/E/27/ECO

Warm White

1/50

2700

82

3200

15000

6.61”

-

32 WATT
T4

GX24q-3

42 WATT
T4

GX24q-4

109034

$ 12,13

PL42T/E/35/ECO

White

1/50

3500

82

3200

15000

6.61”

-

109036

$ 12,13

PL42T/E/41/ECO

Cool White

1/50

4100

82

3200

15000

6.61”

-

109072

$ 12,13

PL42T/E/50/ECO

Natural White

1/50

5000

82

3200

15000

6.61”

-

44806

X $ 12,13

PL57T/E/27/ECO

Warm White

1/50

2700

82

4200

12000

7.57”

-

44807

$ 12,13

PL57T/E/41/ECO

Cool White

1/50

4100

82

4200

12000

7.57”

-

44808

$ 12,13

PL57T/E/50/ECO

Natural White

1/50

5000

82

4200

12000

7.57”

-

57 WATT
T4

GX24q-5

Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 67

COMPACT FLUORESCENT LAMPS
Plug-In
Flat
Quad
Bulb

Product
Number

Base

Product
Code

Description

Pkg.
Qty.

Color
Temp.

CRI

Lumens

Avg.
Life

MOL

MOD

High Lumen Long 4-Pin

18 WATT
T5

Footnotes

PLL

2G11

109700

$ 13

PLL18/835/ECO

White

10/40

3500

82

1250

12000

8.94”

-

109702

$ 13

PLL18/841/ECO

Cool White

10/40

4100

82

1250

12000

8.94”

-

24 WATT
T5

2G11

109704

$ 13

PLL24/835/ECO

White

10/40

3500

82

1800

12000

12.70”

-

109706

$ 13

PLL24/841/ECO

Cool White

10/40

4100

82

1800

12000

12.70”

-

109708

$ 13

PLL36/835/ECO

White

10/40

3500

82

2800

12000

16.45”

-

109710

$ 13

PLL36/841/ECO

Cool White

10/40

4100

82

2800

12000

16.45”

-

109712

$ 13

PLL40/830/RS/ECO

Soft White

10/40

3000

82

3150

20000

22.50”

-

109714

$ 13

PLL40/835/RS/ECO

White

10/40

3500

82

3150

20000

22.50”

-

109716

$ 13

PLL40/841/RS/ECO

Cool White

10/40

4100

82

3150

20000

22.50”

-

44900

$ 13

PLL40/850/RS/ECO

Natural White

10/40

5000

82

3150

20000

22.50”

-

109718

$ 13

PLL55/835/ECO

White

10/40

3500

82

4700

12000

21.20”

-

109720

$ 13

PLL55/841/ECO

Cool White

10/40

4100

82

4700

12000

21.20”

-

Natural White

1/50

5000

82

1700

10000

5.90”

3.23”

36 WATT
T5

2G11

40 WATT
T5

2G11

55 WATT
T5

2G11

Flat Quad 4-Pin Electronic

27 WATT
T5

GX10q-2

109238

$ 13

FML27/NDL

Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.

68

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

COMPACT FLUORESCENT LAMPS
Bulb and Base Identification Guide
Bulb Shapes

Single Tube
2-Pin

Single Tube
4-Pin

Double Tube
2-Pin/4-Pin

Triple Tube
4-Pin

Flat Quad
4-Pin

Double
15mm

PLL
4-Pin

®

®

R20

BR38

R30/R40

A-Shape

Plug-In R40

®

®

®

®

G
Globe

PAR20

PAR38

PAR30

®
®

®
®

B13
Torpedo

Spiral
GU24

TS EX39

Spiral

T20
Tubular

Base Types

G23

GX24q-3

GX23

GX24q-4

GX23-2

GX24q-5

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

GX24d-3

G24q-1

2G11

G24q-2

2GX7

G24q-3

Medium
E26/27

G24d-2

E12

GU24

EX39

TOC 69

COMPACT FLUORESCENT LAMPS
Cross Reference Guide
HALCO

G.E.

PHILIPS

OSRAM/SYLVANIA

PL5S/27/ECO

F5BX/827/ECO

PL-S 5W/827/2P/ALTO

CF5DS/827

PL5S/41/ECO

F5BX/841/ECO

PL-S 5W/841/2P/ALTO

CF5DS/841

PL7S/27/ECO

F7BX/827/ECO

PL-S 7W/827/2P/ALTO

CF7DS/827

PL7S/35/ECO

F7BX/835/ECO

PL-S 7W/835/2P/ALTO

CF7DS/835

PL7S/41/ECO

F7BX/841/ECO

PL-S 7W/841/2P/ALTO

CF7DS/841

PL9S/27/ECO

F9BX/827/ECO

PL-S 9W/827/2P/ALTO

CF9DS/827

PL9S/35/ECO

F9BX/835/ECO

PL-S 9W/835/2P/ALTO

CF9DS/835

PL9S/41/ECO

F9BX/841/ECO

PL-S 9W/841/2P/ALTO

CF9DS/841

PL9S/50/ECO

-

PL-S 9W/850/2P/ALTO

CF9DS/850

PL13S/27/ECO

F13BX/827/ECO

PL-S 13W/827/2P/ALTO

CF13DS/827

PL13S/35/ECO

F13BX/835/ECO

PL-S 13W/835/2P/ALTO

CF13DS/835

PL13S/41/ECO

F13BX/841/ECO

PL-S 13W/841/2P/ALTO

CF13DS/841

PL13S/50/ECO

F13BX/850/ECO

PL-S 13W/850/2P/ALTO

CF13DS/850

PL9D/27/ECO

F9DBX23/827/ECO

-

CF9DD/827

PL9D/41/ECO

F9DBX23/841/ECO

-

CF9DD/841

PL13D/27/ECO

F13DBX23/827/ECO

PL-C 13W/827/USA/ALTO

CF13DD/827

PL13D/35/ECO

F13DBX23/835/ECO

PL-C 13W/835/USA/ALTO

CF13DD/835

PL13D/41/ECO

F13DBX23/841/ECO

PL-C 13W/841/USA/ALTO

CF13DD/841

PL13D/50/ECO

-

-

-

PL18D/27/ECO

F18DBX/827/ECO

PL-C 18W/827/ALTO

CF18DD/827

PL18D/35/ECO

F18DBX/835/ECO

PL-C 18W/835/ALTO

CF18DD/835

PL18D/41/ECO

F18DBX/841/ECO

PL-C 18W/841/ALTO

CF18DD/841

PL18D/50/ECO

-

-

-

PL26D/27/ECO

F26DBX/827/ECO

PL-C 26W/827/ALTO

CF26DD/827

PL26D/35/ECO

F26DBX/835/ECO

PL-C 26W/835/ALTO

CF26DD/835

PL26D/41/ECO

F26DBX/841/ECO

PL-C 26W/841/ALTO

CF26DD/841

PL26D/50/ECO

-

-

-

PL22D/28

-

PL-C 15MM/22W/827

-

PL22D/50

-

-

-

PL28D/28

-

PL-C 15MM/28W/827

-

PL28D/50

-

-

-

Single Tube 2-Pin

Double Tube 2-Pin

Single Tube 4-Pin Electronic
PL13S/E/27/ECO

-

-

CF13DS/E/827

PL13S/E/35/ECO

-

-

-

PL13S/E/41/ECO

-

-

CF13DS/E/841

PL13S/E/50/ECO

-

-

-

70

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

COMPACT FLUORESCENT LAMPS
Cross Reference Guide
HALCO

G.E.

PHILIPS

OSRAM/SYLVANIA

Double Tube 4-Pin Electronic
PL13D/E/27/ECO

F13DBX/827/ECO4P

PL-C 13W/827/4P/ALTO

CF13DD/E/827

PL13D/E/30/ECO

F13DBX/830/ECO4P

PL-C 13W/830/4P/ALTO

CF13DD/E/830

PL13D/E/35/ECO

F13DBX/835/ECO4P

PL-C 13W/835/4P/ALTO

CF13DD/E/835

PL13D/E/41/ECO

F13DBX/841/ECO4P

PL-C 13W/841/4P/ALTO

CF13DD/E/841

PL13D/E/50/ECO

-

-

-

PL18D/E/27/ECO

F18DBX/827/ECO4P

PL-C 18W/827/4P/ALTO

CF18DD/E/827

PL18D/E/35/ECO

F18DBX/835/ECO4P

PL-C 18W/835/4P/ALTO

CF18DD/E/835

PL18D/E/41/ECO

F18DBX/841/ECO4P

PL-C 18W/841/4P/ALTO

CF18DD/E/841

PL18D/E/50/ECO

-

-

-

PL26D/E/27/ECO

F26DBX/827/ECO4P

PL-C 26W/827/4P/ALTO

CF26DD/E/827

PL26D/E/35/ECO

F26DBX/835/ECO4P

PL-C 26W/835/4P/ALTO

CF26DD/E/835

PL26D/E/41/ECO

F26DBX/841/ECO4P

PL-C 26W/841/4P/ALTO

CF26DD/E/841

PL26D/E/50/ECO

-

-

-

Triple Tube 4-Pin Electronic
PL18T/E/27/ECO

F18TBX/827/A/ECO

PL-T 18W/827/4P/ALTO

CF18DT/E/IN/827

PL18T/E/35/ECO

F18TBX/835/A/ECO

PL-T 18W/835/4P/ALTO

CF18DT/E/IN/835

PL18T/E/41/ECO

F18TBX/841/A/ECO

PL-T 18W/841/4P/ALTO

CF18DT/E/IN/841

PL18T/E/50/ECO

-

-

-

PL26T/E/27/ECO

F26TBX/827/A/ECO

PL-T 26W/827/4P/ALTO

CF26DT/E/IN/827

PL26T/E/35/ECO

F26TBX/835/A/ECO

PL-T 26W/835/4P/ALTO

CF26DT/E/IN/835

PL26T/E/41/ECO

F26TBX/841/A/ECO

FL-T 26W/841/4P/ALTO

CF26DT/E/IN/841

PL26T/E/50/ECO

-

-

-

PL32T/E/27/ECO

F32TBX/827/A/ECO

PL-T 32W/827/4P/ALTO

CF32DT/E/IN/827

PL32T/E/35/ECO

F32TBX/835/A/ECO

PL-T 32W/835/4P/ALTO

CF32DT/E/IN/835

PL32T/E/41/ECO

F32TBX/841/A/ECO

PL-T 32W/841/4P/ALTO

CF32DT/E/IN/841

PL32T/E/50/ECO

-

-

-

PL42T/E/27/ECO

F42TBX/827/A/ECO

PL-T 42W/827/4P/ALTO

CF42DT/E/IN/827

PL42T/E/35/ECO

F42TBX/835/A/ECO

PL-T 42W/835/4P/ALTO

CF42DT/E/IN/835

PL42T/E/41/ECO

F42TBX/841/A/ECO

PL-T 42W/841/4P/ALTO

CF42DT/E/IN/841

PL42T/E/50/ECO

-

-

-

PL57T/E/27/ECO

F57QBX/827/A/ECO

-

CF57DT/E/IN/827

PL57T/E/41/ECO

F57QBX/841/A/ECO

PL-T 57W/841/4P/A

CF57DT/E/IN/841

PL57T/E/50/ECO

F57QBX/850/A/ECO

-

CF57DT/E/IN/850

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 71

COMPACT FLUORESCENT LAMPS
Cross Reference Guide
HALCO

G.E.

PHILIPS

OSRAM/SYLVANIA

PLL18/835/ECO

F18BX/SPX35

PL-L 18W/835/4P

FT18DL/835/RS

PLL18/841/ECO

F18BX/SPX41

PL-L 18W/841/4P

FT18DL/841/RS

PLL24/835/ECO

F27BX/SPX35/RS

PL-L 24W/835/4P

FT24DL/835

PLL24/841/ECO

F27BX/SPX41/RS

PL-L 24W/841/4P

FT24DL/841

PLL36/835/ECO

F39BX/SPX35/RS

PL-L 36W/835/4P

FT36DL/835

PLL36/841/ECO

F39BX/SPX41/RS

PL-L 36W/841/4P

FT36DL/841

PLL40/830/RS/ECO

F40/30BX/SPX30

PL-L 40W/830/4P/RS/IS

FT40DL/830/RS

PLL40/835/RS/ECO

F40/30BX/SPX35

PL-L 40W/835/4P/RS/IS

FT40DL/835/RS

PLL40/841/RS/ECO

F40/30BX/SPX41

PL-L 40W/841/4P/RS/IS

FT40DL/841/RS

PLL40/850/RS/ECO

F40/30BX/SPX50

-

FT40DL/850/RS

PLL55/835/ECO

F55BX/835

PL-L 50W/835/4P/RS

FT55DL/835

PLL55/841/ECO

F55BX/840

PL-L 50W/841/4P/RS

FT55DL/841

High Lumen Long 4-Pin

72

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

COMPACT FLUORESCENT LAMPS
Symbols, Footnotes and Abbreviations
SYMBOLS
$

Energy saving product.
ProLume Eco-Shield® Low-Mercury Fluorescent lamps pass the Federal TCLP for hazardous wastes.
®



New product introduced within the past year.

X

Product will be discontinued when inventory is depleted.

FOOTNOTES
1

UL approved for damp location in base-up position only. All other base positions must be in a dry
environment or in a weatherproof fixture.

2

UL approved for wet location in base-up position only. All other base positions must be in a dry
environment or in a weatherproof fixture.

3

UL approved for totally enclosed fixtures with a max ballast case temperature of 90°C for GU24 base,
75°C for medium base lamps.

4

Not intended for use with emergency exit fixtures, dimmers, timing devices, photo sensors or
occupancy sensors.

5 Do not use where lamp is exposed to moisture.
6 For use on analog dimmers only - may not be compatible with all dimmers.
7 Do not use in totally enclosed fixtures or in recessed fixtures.
8 Do not use in totally enclosed fixtures or insulated contact air tight (ICAT) rated fixtures.
9 Use only on 277 Volts, 60-hertz frequency.
10 PL 5 watt lamps should not be used in socket or adapters rated for 7 or 9 watt lamps.
11

Total wattage consumption for adapter systems is higher than lamp wattage due to ballast losses.
Total system wattage equals lamp wattage plus 2 ballast watts.

12

This 4-Pin Electronic lamp has an internal end-of-life (EOL) mechanism that shuts the lamp down
to prevent abnormal end-of-life failure.

13

Operate this lamp on a high-frequency Compact Fluorescent ballast with an end-of-life shut
down circuit.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 73

COMPACT FLUORESCENT LAMPS
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
/27 Suffix used to indicate color temperature of 2700K.
/30 Suffix used to indicate color temperature of 3000K.
/35 Suffix used to indicate color temperature of 3500K.
/3WAY Suffix used to indicate 3-Way lamps.
/41 Suffix used to indicate color temperature of 4100K.
/4PK Suffix used to indicate a package of (4) Compact Fluorescent lamps.
/50 Suffix used to indicate color temperature of 5000K.
/65 Suffix used to indicate color temperature of 6500K.
BLB Code abbreviation for Blacklight-Blue lamps.
CFL Code abbreviation for ProLume® Self-Ballasted Compact Fluorescent lamps.
BLU Code abbreviation for Blue lamps.
/CS Suffix used to indicate CoverShield® safety coated lamps.
D Code abbreviation for Double Tube lamps.
/DIM Suffix used to indicate Dimmable lamps.
/E Suffix used to indicate Electronic 4-Pin Plug-In lamps.
/ECO Suffix used to indicate Eco-Shield® TCLP compliant lamps.
GRN Code abbreviation for Green lamps.
/PB Suffix used to indicate Pool Bright pool lamps color temperature of 6450K.
PL Code abbreviation for ProLume® Plug-In Compact Fluorescent lamps.
PLL Code abbreviation for ProLume® Plug-In High Lumen long lamps.
PNK Code abbreviation for Pink lamps.
S Code abbreviation for Single Tube Plug-In lamps.
SP Code abbreviation for Spiral Tube Plug-In lamps.
T Code abbreviation for Triple Tube Plug-In lamps.
YEL Code abbreviation for Yellow lamps.

74

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

®

LINEAR FLUORESCENT LAMPS
CONTENTS
78 How to Read a Table
79 T5, T8, T12 Preheat Lamps
79 T5 Programmed Start Lamps
80 T8 Rapid Start Lamps
82 T12 Rapid Start Lamps
82 T6, T12 Slimline Instant Start Lamps
83 T8, T12 High Output Lamps
83 T8, T12 Very High Output Lamps
83 T8, T12 U-Bend Lamps
84 T5, T9 Circline Lamps
84 T8, T12 Appliance Lamps
84 T5, T8, T12 Blacklight & Blacklight-Blue
85 Base and Bulb Identification
86 Cross Reference Guide
90 Symbols, Footnotes and Abbreviations

main
TOC

HOW TO READ A LINEAR FLUORESCENT
LAMP TABLE
PACKAGE QUANTITY

Indicates minimum sell quantity
and smallest shipping carton.

BULB

Designations indicate shape and size.
Illustrations can be found on page 85.
and at the top of each page.

Abbreviated product description
can also be used for ordering.
A key to abbreviations can be
found on page 91.

Indicates the
power consumed
by the lamp during
operation.

Bulb

Watts

Product
Number

Product
Code

Footnotes

Average rated
life expressed
in hours.

A term used to
describe the color
of a light source
and is expressed
in degrees
“Kelvin”(K).

PRODUCT CODE

WATTS

AVERAGE
LIFE

COLOR
TEMP.

INITIAL
LUMENS

The lamp’s
average light
output after
the initial
100 hours of
operation.

Description

Pkg.
Qty.

Color
Temp.

CRI

Initial
Lumens

Mean
Lumens

Avg.
Life

Nom.
Length

Preheat - Medium Bi-Pin
T8

14

109370

1

F14T8CW

Cool White

25

4100

62

650

585

8000

14”

15

9202

1

F15T8CW

Cool White

30

4100

62

770

690

8000

17”

15

109212

1

F15T8DL

Daylight

30

6500

74

770

690

8000

17”

15

109208

1

F15T8WW

Warm White

30

3000

53

845

750

8000

17”

30

9225

1

F30T8CW

Cool White

30

4100

62

2100

1900

9000

35”

FOOTNOTES &
SYMBOLS

Related footnotes can
be found on page 90.

DESCRIPTION

Bulb finish and other
important information.

MEAN
LUMENS

PRODUCT
NUMBER

Use this number when
placing an order.

The lamp’s average
light output at 40%
of rated life.

CRI

An international
scale from 0 to 100 that
indicates the relative color
rendering value of a light
source. The color rendering
index expresses the degree
to which colors will look
“natural” under a given light
source.

TOC

NOM.
LENGTH

A measurement for
fluorescent lamp
length based on the
length of the lamp
plus an allowance
for the luminaire’s
lamp holders.

LINEAR FLUORESCENT LAMPS
T8 Med.
Bi-Pin

T12 Med.
Bi-Pin

Bulb

Watts

Product
Number

T5
Miniature Bi-Pin

Product
Code

Footnotes

Pkg.
Qty.

Description

Color
Temp.

CRI

Initial
Lumens

Mean
Lumens

Avg.
Life

Nom.
Length

Preheat - Miniature Bi-Pin
T5

4

9213

1,7

F4T5CW

Cool White

10/1000 4100

65

130

117

6000

6”

6

9200

1,7

F6T5CW

Cool White

10/500

4100

65

240

216

6000

9”

8

9206

1,7

F8T5BLB

Blacklight-Blue

10/500

-

-

-

-

6000

12”

8

9201

1,7

F8T5CW

Cool White

10/500

4100

65

350

315

6000

12”

8

9215

1,7

F8T5DL

Daylight

10/500

6500

75

350

279

6000

12”

8

9210

1,7

F8T5WW

Warm White

10/500

3000

53

400

380

6000

12”

13

9231

1,7

F13T5CW

Cool White

10/200

4100

65

740

666

6000

21”

13

9232

1,7

F13T5WW

Warm White

10/200

3000

53

870

825

6000

21”

Preheat - Medium Bi-Pin
T8

T12

14

109370

1

F14T8CW

Cool White

25

4100

62

650

585

8000

14”

15

9202

1

F15T8CW

Cool White

30

4100

62

770

690

8000

17”

15

109212

1

F15T8DL

Daylight

30

6500

74

770

690

8000

17”

15

109208

1

F15T8WW

Warm White

30

3000

53

845

750

8000

17”

30

9225

1

F30T8CW

Cool White

30

4100

62

2100

1900

9000

35”

14

9228

1

F14T12CW

Cool White

30

4100

62

480

432

9000

14”

15

9212

1

F15T12CW

Cool White

30

4100

62

650

570

9000

17”

20

9203

1

F20T12CW

Cool White

30

4100

62

1150

1000

8000

24”

20

9235

1

F20T12DL

Daylight

30

6500

74

1100

960

8000

24”

20

9227

1

F20T12WW

Warm White

30

3000

52

1200

1080

8000

24”

25

3000

86

1350

1270

24000

22”

T-5 Programmed Start - Miniature Bi-Pin
T5

Eco-Shield®

14

30117

1,7

F14T5/830/ECO/IC

830 Phosphor

14

30118

1,7

F14T5/835/ECO/IC

835 Phosphor

25

3500

86

1350

1270

24000

22”

14

30119

1,7

F14T5/841/ECO/IC

841 Phosphor

25

4100

86

1350

1270

24000

22”

21

30125

1,7

F21T5/830/ECO/IC

830 Phosphor

25

3000

86

2100

1990

24000

34”

21

30126

1,7

F21T5/835/ECO/IC

835 Phosphor

25

3500

86

2100

1990

24000

34”

21

30127

1,7

F21T5/841/ECO/IC

841 Phosphor

25

4100

86

2100

1990

24000

34”

24

30134

1,7

F24T5/835/HO/ECO/IC

835 Phosphor High Output

25

3500

86

2000

1900

20000

22”

24

30135

1,7

F24T5/841/HO/ECO/IC

841 Phosphor High Output

25

4100

86

2000

1900

20000

22”

28

35041

E

1,7

F28T5/830/ECO/IC

830 Phosphor

25

3000

86

2900

2750

24000

46”

28

35042

E

1,7

F28T5/835/ECO/IC

835 Phosphor

25

3500

86

2900

2750

24000

46”

28

35046

X 1,7

F28T5/835/ECO/XL

835 Phosphor

25

3500

86

2800

2660

40000

46”

28

35043

1,7

F28T5/841/ECO/IC

841 Phosphor

25

4100

86

2900

2750

24000

46”

28

90016

F28T5/841/ECO/IC/CS

841 Phosphor, CoverShield®

25

4100

86

2900

2750

24000

46”

28

35044

F28T5/850/ECO/IC

850 Phosphor

25

5000

86

2900

2750

24000

46”

E

E
E

X 1,7
E

1,7

E Means this lamp meets Federal Minimum Efficiency standards.
Linear Fluorescent lamp symbols, footnotes and abbreviations are located on pages 90-91.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 79

LINEAR FLUORESCENT LAMPS
T5
Miniature Bi-Pin

Bulb

Watts

Product
Number

Product
Code

Footnotes

Pkg.
Qty.

Description

T-5 Programmed Start - Miniature Bi-Pin
T5

35

35049

1,7

F35T5/835/ECO/IC

835 Phosphor

35

35050

1,7

F35T5/841/ECO/IC

39

35060

X 1,7

CRI

Eco-Shield® continued

Initial
Lumens

Mean
Lumens

Avg.
Life

Nom.
Length

25

3500

86

3650

3450

24000

58”

841 Phosphor

25

4100

86

3650

3450

24000

58”

F39T5/830/HO/ECO/IC

830 Phosphor High Output

25

3000

86

3500

3320

24000

34”

39

35061

1,7

F39T5/835/HO/ECO/IC

835 Phosphor High Output

25

3500

86

3500

3320

24000

34”

39

35062

1,7

F39T5/841/HO/ECO/IC

841 Phosphor High Output

25

4100

86

3500

3320

24000

34”

49

35085

E

$ 1,7

F49T5/835/HO/ECO

25

3500

86

4900

4700

24000

46”

49

35088

E

$ 1,7

F49T5/841/HO/ECO

25

4100

86

4900

4700

24000

46”

49

35089

E

$ 1,7

F49T5/850/HO/ECO

835 Phosphor High Output,
Energy Saver
841 Phosphor High Output,
Energy Saver
850 Phosphor High Output,
Energy Saver

25

5000

86

4900

4700

24000

46”

54

35081

E

1,7

F54T5/830/HO/ECO/IC

830 Phosphor High Output

25

3000

86

5000

4850

24000

46”

54

35082

E

1,7

F54T5/835/HO/ECO/IC

835 Phosphor High Output

25

3500

86

5000

4850

24000

46”

25

3500

86

5000

4850

24000

46”

25

3500

86

5000

4790

40000

46”

54

90051

54

35070

54

105680

E

1,7

F54T5/841/HO/ECO

841 Phosphor High Output

25

4100

86

5000

4850

24000

46”

54

35083

E

1,7

F54T5/841/HO/ECO/IC

841 Phosphor High Output

25

4100

86

5000

4850

24000

46”

25

4100

86

5000

4850

24000

46”

25

4100

86

5000

4790

40000

46”

25

5000

86

5000

4850

24000

46”

25

5000

86

5000

4850

24000

46”

25

5000

86

5000

4790

40000

46”
46”

54

90052

54

35071

54

35084

54

90053

54

35072

54

35086

80
80

E
E

X 1,7

E
E

1,7

X 1,7
E
E

E

1,7

835 Phosphor High Output,
F54T5/835/HO/ECO/IC/CS CoverShield®
835 Phosphor High Output,
F54T5/835/HO/ECO/XL
Extended Life

1,7
1,7

X 1,7

841 Phosphor High Output,
F54T5/841/HO/ECO/IC/CS CoverShield®
841 Phosphor High Output,
F54T5/841/HO/ECO/XL
Extended Life
F54T5/850/HO/ECO/IC

850 Phosphor High Output

850 Phosphor High Output,
F54T5/850/HO/ECO/IC/CS CoverShield®
850 Phosphor High Output,
F54T5/850/HO/ECO/XL
Extended Life

1,7

F54T5/865/HO/ECO/IC

865 Phosphor High Output

25

6500

86

5000

4850

24000

35087

1,7

F80T5/835/HO/ECO

835 Phosphor High Output

25

3500

86

7000

6650

24000 57.1”

35090

1,7

F80T5/841/HO/ECO

841 Phosphor High Output

25

4100

86

7000

6650

24000 57.1”

E

T-8 Rapid Start - Medium Bi-Pin
T8

Color
Temp.

T8 Med.
Bi-Pin

Eco-Shield®

17

109320

1

F17T8/730/ECO

730 Phosphor

25

3000

78

1350

1280

24000

24”

17

109322

1

F17T8/735/ECO

735 Phosphor

25

3500

78

1350

1280

24000

24”

17

109324

1

F17T8/741/ECO

741 Phosphor

25

4100

78

1350

1280

24000

24”

17

109326

1

F17T8/750/ECO

750 Phosphor

25

5000

78

1350

1280

24000

24”

17

35170

1

F17T8/830/ECO

830 Phosphor

25

3000

86

1400

1330

24000

24”

17

109802

1

F17T8/835/ECO

835 Phosphor

25

3500

86

1400

1330

24000

24”

17

109804

1

F17T8/841/ECO

841 Phosphor

25

4100

86

1400

1330

24000

24”

17

35180

1

F17T8/850/ECO

850 Phosphor

25

5000

86

1400

1330

24000

24”

E Means this lamp meets Federal Minimum Efficiency standards.
Linear Fluorescent lamp symbols, footnotes and abbreviations are located on pages 90-91.

80

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

LINEAR FLUORESCENT LAMPS
T8 Med.
Bi-Pin

Bulb

Watts

Product
Number

Product
Code

Footnotes

T-8 Rapid Start - Medium Bi-Pin
T8

Pkg.
Qty.

Description

Eco-Shield® continued

Color
Temp.

CRI

Initial
Lumens

Mean
Lumens

Avg.
Life

Nom.
Length

25

109340

1

F25T8/730/ECO

730 Phosphor

25

3000

78

2150

2050

24000

36”

25

109342

1

F25T8/735/ECO

735 Phosphor

25

3500

78

2150

2050

24000

36”

25

109344

1

F25T8/741/ECO

741 Phosphor

25

4100

78

2150

2050

24000

36”

25

109346

1

F25T8/750/ECO

750 Phosphor

25

5000

78

2150

2050

24000

36”

25

109806

1

F25T8/830/ECO

830 Phosphor

25

3000

86

2250

2140

24000

36”

25

109808

1

F25T8/835/ECO

835 Phosphor

25

3500

86

2250

2140

24000

36”

25

109810

1

F25T8/841/ECO

841 Phosphor

25

4100

86

2250

2140

24000

36”

25

35162

E

$ 1,8

F25T8ES/830/ECO

830 Phosphor, Energy Saver

25

3000

86

2500

2380

24000

48”

25

35172

E

$ 1,8

F25T8ES/835/ECO

835 Phosphor, Energy Saver

25

3500

86

2500

2380

24000

48”

25

35173

E

$ 1,8

F25T8ES/841/ECO

841 Phosphor, Energy Saver

25

4100

86

2500

2380

24000

48”

25

35174

E

$ 1,8

F25T8ES/850/ECO

850 Phosphor, Energy Saver

25

5000

86

2500

2380

24000

48”

28

25

3000

86

2800

2660

24000

48”

28

25

3500

86

2800

2660

24000

48”

28

90081

28

109366

E

28

109368

32

35175

E

$1

F28T8/830/ECO

830 Phosphor

109364

E

$1

F28T8/835/ECO

835 Phosphor

F28T8/835/ECO/IC/CS

835 Phosphor, CoverShield

25

3500

86

2800

2660

24000

48”

$1

F28T8/841/ECO

841 Phosphor

25

4100

86

2800

2660

24000

48”

E

$1

F28T8/850/ECO

850 Phosphor

25

5000

86

2800

2660

24000

48”

109412

E

L,1

F32T8/730/ECO

730 Phosphor

25

3000

78

2850

2700

24000

48”

32

109414

E

L,1

F32T8/735/ECO

735 Phosphor

25

3500

78

2850

2700

24000

48”

32

90084

F32T8/735/ECO/CS

735 Phosphor, CoverShield®

25

3500

78

2850

2700

24000

48”

32

109416

F32T8/741/ECO

741 Phosphor

25

4100

78

2850

2700

24000

48”

32

90085

F32T8/741/ECO/CS

741 Phosphor, CoverShield®

25

4100

78

2850

2700

24000

48”

32

109418

F32T8/750/ECO

750 Phosphor

25

5000

78

2850

2700

24000

48”

32

90089

F32T8/750/ECO/CS

750 Phosphor, CoverShield

25

5000

78

2850

2700

24000

48”

32

30170

L,1

F32T8/765/ECO

765 Phosphor

25

6500

78

2850

2700

24000

48”

32

109398

E

1

F32T8/830/ECO

830 Phosphor

25

3000

86

3050

2900

24000

48”

32

109400

E

1

F32T8/835/ECO

835 Phosphor

25

3500

86

3050

2900

24000

48”

32

35176

E

1

F32T8/835/ECO/HL

835 Phosphor High Lumen

25

3500

86

3150

3000

24000

48”

32

90094

E

1

F32T8/835/ECO/CS

835 Phosphor, CoverShield®

25

3500

86

3050

2900

24000

48”

32

109402

E

1

F32T8/841/ECO

841 Phosphor

25

4100

86

3050

2900

24000

48”

32

35177

E

1

F32T8/841/ECO/HL

841 Phosphor High Lumen

25

4100

86

3150

3000

24000

48”

32

90095

E

1

F32T8/841/ECO/CS

841 Phosphor, CoverShield

25

4100

86

3050

2900

24000

48”

32

109404

E

1

F32T8/850/ECO

850 Phosphor

25

5000

86

3050

2900

24000

48”

32

35178

E

1

F32T8/850/ECO/HL

850 Phosphor High Lumen

25

5000

86

3150

3000

24000

48”

32

90096

E

1

F32T8/850/ECO/CS

850 Phosphor, CoverShield

25

5000

86

3050

2900

24000

48”

32

109428

E

F32T8/865/ECO

865 Phosphor

25

6500

86

3050

2900

24000

48”

E

X$1

E
E

L,1
E

E

1

L,1
E

E

1

1

1

®

®

®

®

E Means this lamp meets Federal Minimum Efficiency standards.
Linear Fluorescent lamp symbols, footnotes and abbreviations are located on pages 90-91.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 81

LINEAR FLUORESCENT LAMPS
T6
Single Pin

Bulb

Watts

Product
Number

Product
Code

Footnotes

Pkg.
Qty.

Description

T-8 Rapid Start - Medium Bi-Pin
T8

T8
Single Pin

T8 Med.
Bi-Pin

Eco-Shield®

T12 Med.
Bi-Pin

T12
Single Pin

Color
Temp.

CRI

Initial
Lumens

Mean
Lumens

Avg.
Life

Nom.
Length

continued

32

37200

1

F32T8BLB

Blacklight-Blue

12

-

-

-

-

20000

48”

40

30171

1

F40T8/735/ECO

735 Phosphor

30

3500

78

3600

3450

24000

60”

40

30172

1

F40T8/741/ECO

741 Phosphor

30

4100

78

3600

3450

24000

60”

58

35179

1

F58T8/840

840 Phosphor

25

4000

86

5300

5000

24000

60”

70

39452

1

F70T8/840/M

840 Phosphor Major

25

4000

85

6000

5985

20000

70”

T-8 Rapid Start - Single Pin
T8

59

23411

E

$1

F96T8/735/M

735 Phosphor Major

24

3500

75

5700

5130

15000

96”

59

23412

E

$1

F96T8/741/M

741 Phosphor Major

24

4100

72

5700

5130

15000

96”

59

205773

E

$1

F96T8/850/M

850 Phosphor Major

24

5000

80

5900

5428

15000

96”

T-12 Rapid Start - Medium Bi-Pin
T12

30

9204

1

F30T12CW

Cool White

30

4100

62

2100

1830

8000

36”

30

9236

1

F30T12DL

Daylight

30

6500

74

1900

1650

8000

36”

30

313742

1

F30T12WW

Warm White Major

30

3000

53

2300

2000

18000

36”

34

24588

1

F34CWX/SS/M

Cool White Deluxe Major

30

4100

87

1925

1656

20000

48”

40

423889

1

F40CWS/ECO/M

Cool White Supreme Major

30

4100

89

2600

2250

20000

48”

40

109480

1

F40/350BL

Blacklight

6

-

-

-

-

20000

48”

40

109490

1

F40BLB

Blacklight-Blue

6

-

-

-

-

20000

48”

Slimline Instant Start - Single Pin
T6

25

24266

1

F42T6CW/M

Cool White Major

24

4100

60

1750

1540

7500

42”

T12

39

363218

1

F48CW/M

Cool White Low Mercury Major

15

4100

62

2950

2600

9000

48”

39

387019

1

F48DL/M

Daylight Low Mercury Major

15

6500

79

2500

2375

9000

48”

50

26001

1

F60CW/M

Cool White Major

30

4100

60

3700

3256

12000

60”

50

23076

1

F60DL/M

Daylight Major

30

6500

76

3000

2640

12000

60”

50

355768

1

F64CW/M

Cool White Major

30

4100

60

3900

3432

12000

64”

50

355776

1

F64DL/M

Daylight Major

30

6500

76

3300

2904

12000

64”

56

369892

1

F72CW/M

Cool White Low Mercury Major

15

4100

59

4450

3900

12000

72”

56

369850

1

F72DL/M

Daylight Low Mercury Major

15

6500

79

3800

3350

12000

72”

70

13764

1

F84CW/M

Cool White Major

15

4100

60

5300

4664

12000

84”

75

423194

1

F96CWS/ECO/M

Cool White Supreme Major

15

4100

89

5000

4250

12000

96”

75

14067

1

F96/735/M

735 Phosphor Major

15

3500

70

6420

5906

12000

96”

E

E Means this lamp meets Federal Minimum Efficiency standards.
Linear Fluorescent lamp symbols, footnotes and abbreviations are located on pages 90-91.

82

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

LINEAR FLUORESCENT LAMPS
T12
Recessed DC

T8
Recessed DC

Bulb

Watts

Product
Number

Footnotes

T8
U-Bend

Product
Code

Description

Pkg.
Qty.

Color
Temp.

CRI

Initial
Lumens

Mean
Lumens

Avg.
Life

Nom.
Length

High Output (800mA) - Recessed DC Base
T8

T12

86

12537

E

1,4,5

F96T8/735HO/M

735 Phosphor High Output Major

24

3500

78

8000

7520

18000

96”

86

12538

E

1,4,5

F96T8/741HO/M

741 Phosphor High Output Major

24

4100

78

8000

7520

18000

96”

35

262790

1,4,5

F24T12CWHO/M

Cool White High Output Major

30

4100

60

1650

1337

9000

24”

35

262741

1,4,5

F24T12DLHO/M

Daylight High Output Major

30

6500

76

1400

1134

9000

24”

42

226464

1,4,5

F30T12CWHO/M

Cool White High Output Major

30

4100

60

2250

1825

9000

30”

45

262865

1,4,5

F36T12CWHO/M

Cool White High Output Major

30

4100

60

2850

2309

9000

36”

45

262907

1,4,5

F36T12DLHO/M

Daylight High Output Major

30

6500

76

2500

2025

9000

36”

55

10559

1,4,5

F42CWHO/M

Cool White High Output Major

30

4100

60

3400

2754

9000

42”

55

10560

1,4,5

F42DLHO/M

Daylight High Output Major

30

6500

76

3050

2471

9000

42”

15

4100

59

4050

3500

12000

48”

15

6500

73

3400

3000

12000

48”

60

369785

1,4,5

F48CWHO/M

60

369843

1,4,5

F48DLHO/M

Cool White High Output
Low Mercury Major
Daylight High Output
Low Mercury Major

75

251260

1,4,5

F60CWHO/M

Cool White High Output Major

30

4100

60

5200

4212

12000

60”

75

25120

1,4,5

F60DLHO/M

Daylight High Output Major

30

6500

76

4600

3826

12000

60”

15

4100

62

6350

5500

12000

72”

15

6500

79

5600

4850

12000

72”

85

366518

1,4,5

F72CWHO/M

85

366534

1,4,5

F72DLHO/M

Cool White High Output
Low Mercury Major
Daylight High Output
Low Mercury Major

100

13766

1,4,5

F84CWHO/M

Cool White High Output Major

15

4100

62

7490

6800

12000

84”

100

13767

1,4,5

F84DLHO/M

Daylight High Output Major

15

6500

76

6700

5427

12000

84”

F96DLHOO/A

Daylight High Output
Low Mercury Major

15

6500

79

7800

6800

12000

96”

110

381774

1,4,5,6

Very High Output (1500mA) - Recessed DC Base
T12

25248

1,4,5

F48CWVHO/M

Cool White Very High Output Major

24

4100

60

6200

4620

10000

48”

160

13760

1,4,5

F72CWVHO/M

Cool White Very High Output Major

15

4100

60

10600

7420

10000

72”

215

342345

1,4,5

F96CWVHO/M

Cool White Very High Output Major

15

4100

60

14000

9800

10000

96”

28

35307

E

$,1,3

FB28/835/6/ECO/IC

835 Phosphor 6”

28

35311

E

$,1,3

FB28/841/6/ECO/IC

31

30301

E

1,3

31

30302

E

31

30303

31

30304

110

U-Bend Rapid Start - Medium Bi-Pin Base
T8

Eco-Shield®
20

3500

86

2650

2450

24000 22.6”

841 Phosphor 6”

20

4100

86

2650

2450

24000 22.6”

FB31/830/ECO

830 Phosphor 1-5/8”

12

3000

86

2750

2600

24000 22.6”

1,3

FB31/835/ECO

835 Phosphor 1-5/8”

12

3500

86

2750

2600

24000 22.6”

E

1,3

FB31/841/ECO

841 Phosphor 1-5/8”

12

4100

86

2750

2600

24000 22.6”

E

1,3

FB31/850/ECO

850 Phosphor 1-5/8”

12

5000

86

2750

2600

24000 22.6”

E Means this lamp meets Federal Minimum Efficiency standards.
Linear Fluorescent lamp symbols, footnotes and abbreviations are located on pages 90-91.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 83

LINEAR FLUORESCENT LAMPS

T9 Circline

T5 Circline

Bulb

Watts

Product
Number

Product
Code

Footnotes

Description

U-Bend Rapid Start - Medium Bi-Pin Base
T8

T12

32

109500

E

L,1,3

FB32/730/6/ECO

730 Phosphor 6”

32

109502

E

L,1,3

FB32/735/6/ECO

32

109504

E

L,1,3

32

109506

E

32

35313

32

109814

E

32

109816

32

109818

40
40

T8 Med.
Bi-Pin

T5

Pkg.
Qty.

Color
Temp.

Eco-Shield®

T12 Med.
Bi-Pin

CRI

Initial
Lumens

U-Bend

Mean
Lumens

Avg.
Life

Nom.
Length

continued

20

3000

78

2750

2400

24000

22.6”

735 Phosphor 6”

20

3500

78

2750

2400

24000

22.6”

FB32/741/6/ECO

741 Phosphor 6”

20

4100

78

2750

2400

24000

22.6”

L,1,3

FB32/750/6/ECO

750 Phosphor 6”

20

5000

78

2750

2400

24000

22.6”

X 1,3

FB32/830/6/ECO/IC

830 Phosphor 6”

20

3000

86

2900

2750

24000

22.6”

1,3

FB32/835/6/ECO

835 Phosphor 6”

20

3500

86

2900

2750

24000

22.6”

E

1,3

FB32/841/6/ECO

841 Phosphor 6”

20

4100

86

2900

2750

24000

22.6”

E

1,3

FB32/850/6/ECO

850 Phosphor 6”

20

5000

86

2900

2750

24000

22.6”

219931

1,3

FB40DX/6/M

Daylight 6” Major

12

6500

84

2250

2125

18000

22.5”

24004

1,3

FB40CWXU6

Cool White 6” Major

12

4100

87

2100

1806

18000

22.5”

9”

E

Circline T5 Programmed Start - 2GX13 Base
T5

22

109080

2,7

FC22T5/835

835 Phosphor

20

3500

82

1900

1800

10000

22

109082

2,7

FC22T5/841

841 Phosphor

20

4100

82

1900

1800

10000

9”

40

109084

2,7

FC40T5/835

835 Phosphor

20

3500

82

3350

3150

10000

12”

40

109086

2,7

FC40T5/841

841 Phosphor

20

4100

82

3350

3150

10000

12”

Circline T9 Rapid Start - G10q Base
T9

22

37501

1

FC8T9CW

Cool White

12

4100

62

1150

1050

10000

8”

22

37503

1

FC8T9DL

Daylight

12

6500

75

1150

1050

10000

8”

30

37504

1

FC9T9/830

830 Phosphor

12

3000

86

1800

1700

10000

9”

32

37507

1

FC12T9CW

Cool White

12

4100

62

2100

2000

10000

12”

40

37510

1

FC16T9CW

Cool White

12

4100

62

2900

2700

10000

16”

Appliance - Medium Bi-Pin Base
T8

T12

18

109234

1

F18T8CW/K24

Cool White 24”

25

4100

62

1175

1025

7500

24”

18

23027

1

F18T8CW/K26

Cool White 26” Major

24

4100

62

1280

1080

7500

26”

18

23028

1

F18T8CW/K28

Cool White 28” Major

24

4100

62

1360

1130

7500

28”

18

23030

1

F18T8CW/K30

Cool White 30” Major

24

4100

62

1400

1200

7500

30”

25

22527

1

F25T12CW/28

Cool White 28” Major

30

4100

62

1670

1450

7500

28”

25

22529

1

F25T12CW/33

Cool White 33” Major

30

4100

62

1850

1200

7500

33”

Blacklight & Blacklight-Blue
T5

8

9206

1

F8T5BLB

Blacklight-Blue

10/500

-

-

-

-

5000

12”

T8

32

37200

1

F32T8BLB

Blacklight-Blue

12

-

-

-

-

20000

48”

T12

40

109490

1

F40BLB

Blacklight-Blue

6

-

-

-

-

20000

48”

1

F40/350BL

Blacklight

6

-

-

-

-

20000

48”

40

109480

E Means this lamp meets Federal Minimum Efficiency standards.
Linear Fluorescent lamp symbols, footnotes and abbreviations are located on pages 90-91.

84

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

LINEAR FLUORESCENT LAMPS
Bulb and Base Identification Guide

Bulb Shapes

Circline

T5

T6

T8

T12

U-Bend

Base Types

Miniature
Bi-Pin

Medium
Bi-Pin

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Recessed DC

Single Pin

TOC 85

LINEAR FLUORESCENT LAMPS
Cross Reference Guide
HALCO

G.E.

PHILIPS

OSRAM/SYLVANIA

F18T8CW/K24

F24”T8CW/4

F18T8/CW/24

F18T8CW/K24

F18T8CW/K26

F26”T8CW/4

F16T8/CW/26

F18T8CW/K26

Preheat Lamps

F18T8CW/K28

F28”T8CW/4

F17T8/CW/28

F18T8CW/K28

F18T8CW/K30

F30”T8CW/4

F18T8/CW/30/ALTO

F18T8CW/K30

F25T12CW/28

F25T12/CW/28

-

F25T12/CW/28

F25T12CW/33

F25T12/CW/33

F25T12/CW

F25T12/CW/33

F14T5/830/ECO/IC

F14W/T5/830/ECO

F14T5/830/ALTO

FP14/830/ECO

F14T5/835/ECO/IC

F14W/T5/835/ECO

F14T5/835/ALTO

FP14/835/ECO

F14T5/841/ECO/IC

F14W/T5/841/ECO

F14T5/841/ALTO

FP14/841/ECO

F21T5/830/ECO/IC

F21W/T5/830/ECO

F21T5/830/ALTO

FP21/830/ECO

Ultra Efficient T-5

F21T5/835/ECO/IC

F21W/T5/835/ECO

F21T5/835/ALTO

FP21/835/ECO

F21T5/841/ECO/IC

F21W/T5/841/ECO

F21T5/841/ALTO

FP21/841/ECO

F28T5/830/ECO/IC

F28W/T5/830/ECO

F28T5/830/ALTO

FP28/830/ECO

F28T5/835/ECO/IC

F28W/T5/835/ECO

F28T5/835/ALTO

FP28/835/ECO

F28T5/841/ECO/IC

F28W/T5/841/ECO

F28T5/841/ALTO

FP28/841/ECO

F28T5/850/ECO/IC

F28W/T5/850/ECO

-

FP28/850/ECO

F28T5/835/ECO/XL

-

-

-

F28T5/841/ECO/XL

-

-

-

F35T5/835/ECO/IC

F35W/T5/835/ECO

F35T5/835/ALTO

FP35/835/ECO

F35T5/841/ECO/IC

F35W/T5/841/ECO

F35T5/841/ALTO

FP35/841/ECO

Ultra Efficient T-5 High Output
F24T5/835/HO/ECO/IC

F24W/T5/835/ECO

F24T5/835/HO/ALTO

FP24/835/HO/ECO

F24T5/841/HO/ECO/IC

F24W/T5/841/ECO

F24T5/841/HO/ALTO

FP24/841/HO/ECO

F39T5/830/HO/ECO/IC

F39W/T5/830/ECO

F39T5/830/HO/ALTO

FP39/830/HO/ECO

F39T5/835/HO/ECO/IC

F39W/T5/835/ECO

F39T5/835/HO/ALTO

FP39/835/HO/ECO

F39T5/841/HO/ECO/IC

F39W/T5/841/ECO

F39T5/841/HO/ALTO

FP39/841/HO/ECO

F49T5/835/HO/ECO/IC

F54T5/835/WM/ECO

F54T5/835/HO/EA/ALTO 49W

-

F49T5/841/HO/ECO/IC

F54T5/841/WM/ECO

F54T5/841/HO/EA/ALTO 49W

-

F49T5/850/HO/ECO/IC

F54T5/850/WM/ECO

F54T5/850/HO/EA/ALTO 49W

-

F54T5/830/HO/ECO/IC

F54W/T5/830/ECO

F54T5/830/HO/ALTO

FP54/830/HO/ECO

F54T5/835/HO/ECO/IC

F54W/T5/835/ECO

F54T5/835/HO/ALTO

FP54/835/HO/ECO

F54T5/841/HO/ECO/IC

F54W/T5/841/ECO

F54T5/841/HO/ALTO

FP54/841/HO/ECO

F54T5/850/HO/ECO/IC

F54W/T5/850/ECO

F54T5/850/HO/ALTO

FP54/850/HO/ECO

F54T5/865/HO/ECO/IC

F54W/T5/865/ECO

F54T5/865/HO/ALTO

FP54/865/HO/ECO

F54T5/835/HO/ECO/XL

-

-

-

F54T5/850/HO/ECO/XL

-

-

-

F80T5/835/HO/ECO/IC

F80W/T5/835/ECO

F80T5/835/HO

FP80/835/HO/ECO

F80T5/841/HO/ECO/IC

F80W/T5/841/ECO

F80T5/841/HO

FP80/841/HO/ECO

86

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

LINEAR FLUORESCENT LAMPS
Cross Reference Guide
HALCO

G.E.

PHILIPS

OSRAM/SYLVANIA

FC22T5/835

-

TL5C 22W/835

FPC22/835

FC22T5/841

-

TL5C 22W/840

FPC22/841

T-5 Ultra Efficient Circline

FC40T5/835

-

TL5C 40W/835

FPC40/835

FC40T5/841

-

TL5C 40W/840

FPC40/841

F17T8/730/ECO

F17T8/SP30/ECO

F17T8/TL730/ALTO

FO17/730/ECO

F17T8/735/ECO

F17T8/SP35/ECO

F17T8/TL735/ALTO

FO17/735/ECO

F17T8/741/ECO

F17T8/SP41/ECO

F17T8/TL741/ALTO

FO17/741/ECO

F17T8/750/ECO

-

-

-

F17T8/830/ECO

F17T8/SPX30/ECO

F17T8/TL830/ALTO

FO17/830/ECO

F17T8/835/ECO

F17T8/SPX35/ECO

F17T8/TL835/ALTO

FO17/835/ECO

T-8 Rapid Start

F17T8/841/ECO

F17T8/SPX41/ECO

F17T8/TL841/ALTO

FO17/841/ECO

F17T8/850/ECO

-

F17T8/TL850/ALTO

-

F25T8/730/ECO

F25T8/SP30/ECO

F25T8/TL730/ALTO

FO25/730/ECO

F25T8/735/ECO

F25T8/SP35/ECO

F25T8/TL735/ALTO

FO25/735/ECO

F25T8/741/ECO

F25T8/SP41/ECO

F25T8/TL741/ALTO

FO25/741/ECO

F25T8/750/ECO

F25T8/SP50/ECO

F25T8/TL750/ALTO

-

F25T8/830/ECO

F25T8/SPX30/ECO

F25T8/TL830/ALTO

FO25/830/ECO

F25T8/835/ECO

F25T8/SPX35/ECO

F25T8/TL835/ALTO

FO25/835/ECO

F25T8/841/ECO

F25T8/SPX41/ECO

F25T8/TL841/ALTO

FO25/841/ECO

F25T8ES/830/ECO

F32T8/25W/SPX30/ECO

F32T8/ADV830/XEW/ALTO 25 WATT

FO32/25W/830/XP/SS/ECO

F25T8ES/835/ECO

F32T8/25W/SPX35/ECO

F32T8/ADV835/XEW/ALTO 25 WATT

FO32/25W/835/XP/SS/ECO

F25T8ES/841/ECO

F32T8/25W/SPX41/ECO

F32T8/ADV841/XEW/ALTO 25 WATT

FO32/25W/841/XP/SS/ECO

F25T8ES/850/ECO

F32T8/25W/SPX50/ECO

F32T8/ADV850/XEW/ALTO 25 WATT

FO32/25W/850/XP/SS/ECO

F28T8/830/ECO

F28T8/XL/SPX30/ECO

F32T8/ADV830/EW/ALTO 28 WATT

FO28/830/XP/SS/ECO

F28T8/835/ECO

F28T8/XL/SPX35/ECO

F32T8/ADV835/EW/ALTO 28 WATT

FO28/835/XP/SS/ECO

F28T8/841/ECO

F28T8/XL/SPX41/ECO

F32T8/ADV841/EW/ALTO 28 WATT

FO28/841/XP/SS/ECO

F28T8/850/ECO

F28T8/XL/SPX50/ECO

F32T8/ADV850/EW/ALTO 28 WATT

-

F32T8/730/ECO

F32T8/SP30/ECO

F32T8/TL730/ALTO

FO32/730/ECO

F32T8/735/ECO

F32T8/SP35/ECO

F32T8/TL735/ALTO

FO32/735/ECO

F32T8/741/ECO

F32T8/SP41/ECO

F32T8/TL741/ALTO

FO32/741/ECO

F32T8/750/ECO

F32T9/SP50/ECO

F32T8/TL750/ALTO

FO32/750/ECO

F32T8/765/ECO

F32T8/SP65/ECO

F32T8/TL765/ALTO

FO32/765/ECO

F32T8/830/ECO

F32T8/SPX30/ECO

F32T8/TL830/ALTO

FO32/830/ECO

F32T8/835/ECO

F32T8/SPX35/ECO

F32T8/TL835/ALTO

FO32/835/ECO

F32T8/841/ECO

F32T8/SPX41/ECO

F32T8/TL841/ALTO

FO32/841/ECO

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 87

LINEAR FLUORESCENT LAMPS
Cross Reference Guide
HALCO

G.E.

PHILIPS

OSRAM/SYLVANIA

F32T8/841/ECO/HL

F32T8/XL/SPX41/HL/ECO

F32T8/ADV841/ALTO

-

F32T8/850/ECO

F32T8/SPX50/ECO

F32T8/TL850/ALTO

FO32/850/ECO

T-8 Rapid Start continued

F32T8/850/ECO/HL

F32T8/XL/SPX50/HL/ECO

F32T8/ADV850/ALTO

-

F32T8/865/ECO

-

-

-

F32T8BLB

-

-

-

F40T8/735/ECO

F40T8/SP35

F40T8/TL735/ALTO

FO40/735/ECO

F40T8/741/ECO

F40T8/SP41

F40T8/TL741/ALTO

FO40/741/ECO

F58T8/840

F58T8/841PLYXLR

-

-

F70T8/840/M

F70T8/840PLYXLR

-

-

F40/DX/ECO

F40/DX/ALTO

F40/DX

T-12 Rapid Start
F40DX/A
F40/350BL

F40BL

F40T12/Blacklight

F40/350BL

F40BLB

F40BLB

-

F40/BLB/RP

F64DL/M

F64T12/D

F64T12/D

F64T12/D

F96T8/735/M

F96T8/SP35

F96T8/TL735/PLUS/ALTO

FO96/735/ECO

F96T8/741/M

F96T8/SP41

F96T8/TL741/PLUS/ALTO

FO96/741/ECO

F96T8/850/M

F96T8/SPX50

F96T8/TL850/PLUS/ALTO

FO96/850/ECO

F96DX/A

F96T12/DX

F96T12/DX/ALTO

F96T12/DX/SS

F96T12/CW/HO/EW/ALTO

F96T12/CW/HO/SS/ECO

Instant Start - Slimline

Rapid Start High Output & Very High Output
F96CWHOES/A

F96T12/CW/HO/WM/ECO

F96CWHOO/A

-

F96T12/CW/HO-O/ALTO

F96T12/CW/HO/CT/ECO

F96CWVHO/M

F96T12/CW/1500

F96T12/CW/VHO-O

F96T12/CW/VHO

88

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

LINEAR FLUORESCENT LAMPS
Cross Reference Guide
HALCO

G.E.

PHILIPS

OSRAM/SYLVANIA

FB28/830/6/ECO

-

-

-

FB28/835/6/ECO

-

-

-

U-Bend Fluorescent

FB28/841/6/ECO

-

-

-

FB32/735/6/ECO

F32T8/SP35/U/6

FB32T8/TL735/6/ALTO

FBO32/735/6/ECO

FB32/741/6/ECO

F32T8/SP41/U/6

FB32T8/TL741/6/ALTO

FBO32/741/6/ECO

FB32/750/6/ECO

-

FB32T8/TL750/6/ALTO

FBO32/750/6/ECO

FB32/830/6/ECO

F32T8/SPX30/U/6

FB32T8/TL830/6/ALTO

FBO32/830/6/ECO

FB32/835/6/ECO

F32T8/SPX35/U/6

FB32T8/TL835/6/ALTO

FBO32/835/6/ECO

FB32/841/6/ECO

F32T8/SPX41/U/6

FB32T8/TL841/6/ALTO

FBO32/841/6/ECO

FB32/850/6/ECO

F32T8/SPX50/U/6

FB32T8/TL850/6/ALTO

-

FB31/830/ECO

F31T8/SPX30/U

-

FBO31/830

FB31/835/ECO

F31T8/SPX35/U

-

FBO31/835

FB31/841/ECO

F31T8/SPX41/U

-

FBO31/841

FB31/850/ECO

-

-

-

FB40DX/6/M

-

FB40/DX/6

-

Brand Name Cross Reference
T5

T5

Silhouette™

Pentron®

T8

T8

TL70/TL80

Octron®

730

SP30

SPEC30 or 730

D30 or 730

830

SPX30

30U or 830

D830

950

C50

C50

DSGN50

ES (Energy Saver)

WM (Watt-Miser®)

EW (Econo-Watt®)

SS (Supersaver®)

Eco-Shield

ECOLUX

ALTO

ECOLOGIC®

ULTRA50

SPX50

50U

850

U-Bend

Mod-U-Line

U-Bent

Curvalume®

®

®

®

®

Watt-Miser, ECOLUX and Mod-U-Line are registered trademarks of General Electric. – Silhouette, Econo-Watt and ALTO are registered trademarks of Philips.
– Pentron, Octron, Supersaver, ECOLOGIC and Curvalume are registered trademarks of Osram/Sylvania.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 89

LINEAR FLUORESCENT
Symbols, Footnotes and Abbreviations
SYMBOLS
$ Energy saving product.
E

This lamp meets Federal Minimum Efficiency standards.
ProLume® Eco-Shield® Low-Mercury Fluorescent lamps pass the Federal TCLP for hazardous wastes.

X Product will be discontinued when inventory is depleted.
L Legislated lamp will not be manufactured after July 14, 2014.

FOOTNOTES
1

Average life under specified test conditions with lamps turned off and restarted every three hours.
Lamp life is longer if lamps are started less frequently.

2

Commercial average rated life under specified test conditions with lamps turned off and restarted every twelve hours.
Lamp life is longer if lamps are started less frequently.

Nominal length is measured from face of base to maximum distant outside point of U-Bend.
3 Leg spacing measured center to center is approximately 6” for /6 product, 3-5/8” for /3 product
and 1-5/8” for FB31 product.
4

Initial lumens are based on 800-mA. operation. For 1000mA. operation, lumens are approximately 10% higher and
wattage approximately 15% higher.

This energy saving lamp is only recommended for use on high power factor lead, indoor ballasts that meet ANSI standards.
The lamp is not recommended for use in drafty areas or locations where the ambient temperature drops below 60°F, except as
5
noted. Do not operate on low power factor ballasts, reduced light or reduced current ballasts, dimming ballasts or emergency
system inverter ballasts.
6 Meets the National Energy Policy Act (EPACT) of 1992 exemption for outdoor or cold temperature applications only.
7 Lamp designed for use with Programmed Start ballast.
8 This lamp should only be operated on high efficiency or anti-striation type ballasts.

90

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

LINEAR FLUORESCENT
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
3 Code abbreviation for 3-5/8” U-Bend lamps.
6 Code abbreviation for 6” U-Bend lamps.
/730 Suffix used to indicate lamps with CRI of 70+ and color temperature of 3000K.
/735 Suffix used to indicate lamps with CRI of 70+ and color temperature of 3500K.
/741 Suffix used to indicate lamps with CRI of 70+ and color temperature of 4100K.
/750 Suffix used to indicate lamps with CRI of 70+ and color temperature of 5000K.
/765 Suffix used to indicate lamps with CRI of 70+ and color temperature of 6500K.
/830 Suffix used to indicate lamps with CRI of 80+ and color temperature of 3000K.
/835 Suffix used to indicate lamps with CRI of 80+ and color temperature of 3500K.
/841 Suffix used to indicate lamps with CRI of 80+ and color temperature of 4100K.
/850 Suffix used to indicate lamps with CRI of 80+ and color temperature of 5000K.
/865 Suffix used to indicate lamps with CRI of 80+ and color temperature of 6500K.
BL Code abbreviation for Blacklight lamps.
BLB Code abbreviation for Blacklight-Blue lamps.
/CS Suffix used to indicate CoverShield® safety coated lamps.
CW Code abbreviation for Cool White lamps.
CWS Code abbreviation for Cool White Supreme lamps.
CWX Code abbreviation for ProLume® Cool White Deluxe lamps.
DL Code abbreviation for Daylight lamps.
DX Code abbreviation for Daylight lamps.
/ECO Suffix used to indicate Eco-Shield® TCLP compliant lamps.
/ES Suffix used to indicate Energy Saving Fluorescent lamps.
FB Prefix used to indicate for Fluorescent U-Bend lamps.
FC Prefix used to indicate for Fluorescent Circline lamps.
/HL Suffix used to indicate High Lumen lamps.
/HO Suffix used to indicate High Output lamps.
HOES Code abbreviation to indicate High Output Energy Saver lamps.
HOO Code abbreviation to indicate High Output lamps for outdoor or low temperature operation.
/IC Suffix used to indicate ProLume® Industrial/Commercial service lamps.
/M Suffix used to indicate Major brand Fluorescent lamps (GE, Philips, Osram/Sylvania).
/VHO Suffix used to indicate Very High Output lamps.
WW Code abbreviation for Warm White lamps.
/XL Suffix used to indicate Extended Life lamps.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC

91

®

HIGH INTENSITY DISCHARGE LAMPS
CONTENTS
94 How to Read a Table
95 Ceramic Discharge Metal Halide Lamps
96 Pulse Start Metal Halide Lamps
97 Protected Metal Halide Lamps
99 Standard Metal Halide Lamps
100 Single Ended Metal Halide Lamps
100 Double Ended Metal Halide Lamps
100 Color Metal Halide Lamps
100 Aquarium Metal Halide Lamps
101 High Pressure Sodium Lamps
102 High Pressure Sodium Non-Cycling Lamps
102 High Pressure Sodium Stand-By Lamps
103 Mercury Vapor Lamps
104 Bulb and Base Identification
105 Cross Reference Guide
110 General Information and Warning Notices
111 Symbols, Footnotes and Abbreviations

main
TOC

HOW TO READ AN HID LAMP TABLE
PACKAGE QUANTITY

Indicates minimum sell quantity
and smallest shipping carton.

BULB

Designations indicate shape and size.
Illustrations can be found on page 104
and at the top of each page.

BASE

Indicates base type.
Full base descriptions and
illustrations can be found
on page 104.

Bulb

Base

Product
Number

Footnotes

AVERAGE
LIFE

Average rated life
expressed in hours.

PRODUCT CODE

Abbreviated product description
can also be used for ordering.
A key to abbreviations can be
found on page 113.

Product
Code

ANSI
CODE

MOL

The specific
electrical
characteristics
of a lamp.

Description

Pkg.
Qty.

ANSI

Initial
Mean
Lumens Lumens

Indicates
maximum
overall length
in inches.

Avg.
Life

MOL

Color
Temp.

CRI

Protected Metal Halide
50 WATT
ED17

Med.

108266

3,13,14,19

MP50/U/MED/PS

Clear

1/12

M110/O

3300

2100

10000

5.45”

4000

65

60505

3,13,14,19

MP50/C/U/MED/PS

Coated

1/12

M110/O

3200

2000

10000

5.45”

3700

70

108268

3,13,14,19

MP70/U/MED/PS

Clear

1/12

M98/O

5300

3400

12000

5.45”

4000

65

60508

3,13,14,19

MP70/C/U/MED/PS

Coated

1/12

M98/O

5000

3300

12000

5.45”

3700

70

70 WATT
ED17

Med.

FOOTNOTES &
SYMBOLS

Related footnotes can
be found on page 111.

WATTS

Indicates the
power consumed
by the lamp during
operation.

PRODUCT
NUMBER

Use this number when
placing an order.

DESCRIPTION

Bulb finish and other
important information.

INITIAL
LUMENS

The lamp’s
average light
output after the
initial 100 hours
of operation.

MEAN
LUMENS

The lamp’s
average light
output at 40%
of rated life.

TOC

COLOR
TEMP.

A term used to
describe the
color of a light
source and is
expressed in
degrees
“Kelvin” (K).

CRI

An international
scale from 0 to 100
that indicates the
relative color rendering
value of a light source.
The color rendering
index expresses the
degree to which colors
will look “natural” under
a given light source.

HID LAMPS
Metal Halide
T4
GU6.5

Bulb

Base

T4
G8.5

Product
Number

T6
G12

T6 Rx7S

Footnotes

MR16
GX10

Product
Code

PAR20

PAR30L

PAR38

ED17

Description

Pkg.
Qty.

ANSI

Initial
Mean
Lumens Lumens

Avg.
Life

MOL

Color
Temp.

CRI

Ceramic Discharge Metal Halide
20 WATT
T4

GU6.5

67010

1,11,18 CDM20/TC/830/GU6.5

Clear

1/24

C156/E

1750

1320

12000

2.44”

3000

85+

G8.5

67012

1,11,18 CDM20/TC/830

Clear

1/24

C156/E

1750

1320

12000

3.35”

3000

85+

G12

67013

1,11,18 CDM20/T6/830

Clear

1/12

C156/E

1750

1320

12000

3.98”

3000

85+

MR16 GX10

67020

3,11,18 CDM20/MR16NFL/830/GX10 Narrow Flood

1/12

C156/O

1200

780

12000

2.56”

3000

85+

PAR20 Med.

67021

3,11,18 CDM20/P20/SP/830

Spot

1/24

C156/O

1200

900

10000

3.74”

3000

85+

67022

3,11,18 CDM20/P20/FL /830

Flood

1/24

C156/O

1200

900

10000

3.74”

3000

85+

GU6.5

67011

1,11,18 CDM35/TC/830/GU6.5

Clear

1/24

3100

2325

12000

2.44”

3000

80+

G8.5

67006

1,11,18 CDM35/TC/830

Clear

1/24

3300

2550

12000

3.35”

3000

80+

G12

67002

1,11,18 CDM35/T6/830

Clear

1/12

3400

2550

12000

3.94”

3000

80+

Rx7S

67016

X 1,11,18 CDM35/TD/830

Clear

1/12

3100

2350

12000

4.69”

3000

80+

PAR20 Med.

67023

3,11,18 CDM35/P20/SP/830

Spot

1/24

2100

1575

10000

3.74”

3000

80+

67000

3,11,18 CDM35/P20/FL/830

Flood

1/24

2100

1575

10000

3.74”

3000

80+

3,11,18 CDM35/P30L/FL/830

Flood

1/6

2200

1650

10000

4.88”

3000

80+

T6

39 WATT
T4

T6

PAR30L Med. 67001

C130/E
M130/E
C130/E
M130/E
C130/E
M130/E
C130/E
M130/E
C130/O
M130/O
C130/O
M130/O
C130/O
M130/O

70 WATT
ED17 Med.

281295

X 1,6,11 MHC70UMED/4K/M

Clear Major

1/12

M98/E
M143/E

5900

4130

20000

5.44”

4000

92

T4

67007

1,11,18 CDM70/TC/830

Clear

1/24

C/M98/E
C/M139/E

6700

5200

12000

3.35”

3000

85+

6700

5300

12000

3.94”

3000

85+

T6

G8.5
G12

Rx7S

67004

1,11,18 CDM70/T6/830

Clear

1/12

C/M98/E
C/M139/E

67014

1,11,18 CDM70/T6/942

Clear

1/12

C/M98/E
C/M139/E

6600

5100

12000

3.94”

4200

90+

67017

1,11,18 CDM70/TD/830

Clear

1/12

M85/E
C/M139/E

6500

4875

12000

4.33”

3000

85+

4850

3640

10000

4.88”

3000

85+

PAR30L Med. 67003

1,11,18 CDM70/P30L/FL/830

Flood

1/6

C/M98/E
C/M139/E

67024

1,11,18 CDM70/P30L/SP/830

Spot

1/6

C/M98/E
C/M139/E

4850

3640

10000

4.88”

3000

85+

67026

1,11,18 CDM70/P30L/FL/942

Flood

1/6

C/M98/E
C/M139/E

4300

3225

10000

4.88”

4200

90+

4300

3200

10000

4.88”

4200

90+

PAR38 Med.

ED17 Med.

67025

X 1,11,18 CDM70/P30L/SP/942

Spot

1/6

C/M98/E
C/M139/E

67028

1,11,18 CDM70/P38/FL/830

Flood

1/6

C/M98/E
C/M139/E

4800

3600

10000

5.64”

3000

85+

67027

1,11,18 CDM70/P38/SP/830

Spot

1/6

C/M98/E
C/M139/E

4800

3600

10000

5.64”

3000

85+

4500

3375

10000

5.64”

4200

90+

6200

4960

16000

5.64”

3000

85+

67029

1,11,18 CDM70/P38/FL/942

Flood

1/12

C/M98/E
C/M139/E

67008

3,11,18 CDM70/U/830/MED

Clear

1/12

C/M98/O
C/M139/O

HID lamp symbols, footnotes and abbreviations are located on pages 111-114.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 95

HID LAMPS
Metal Halide
ED17

Bulb

Base

Product
Number

Footnotes

Product
Code

Description

T6
G12

PAR38

Pkg.
Qty.

T7 Rx7S

Initial
Mean
Lumens Lumens

ANSI

ED28

Avg.
Life

MOL

Color
Temp.

CRI

Ceramic Discharge Metal Halide continued
100 WATT
ED17 Med.

281352

PAR38 Med.

45681
45680

Clear Major

1/12

3,11 CDM100/P38/FL/830/M

Flood Major

1/6

3,11 CDM100/P38/SP/830/M

Spot Major

1/6

Clear

1/12

1,6,11 MHC100UMED/4K/M

150 WATT

M90/E
M140/E
M90/O
M140/O
M90/O
M140/O
C/M102/E
C/M142/E
C/M102/E
C/M142/E
C/M102/E
C/M142/E

9000

6750

20000

5.44”

4000

92

6500

4550

10000

5.31”

3000

81

6500

4550

10000

5.31”

3000

81

14000

11200

16000

5.31”

3000

85+

14000

10500

12000

3.94”

3000

85+

13000

9750

12000

3.94”

4200

93+

ED17 Med.

67009

T6

67005

1,11,26,18 CDM150/T6/830

Clear

1/60

67015

1,11,26,18 CDM150/T6/942

Clear

1/60

Clear

1/12

M110/E

3400

2200

10000

5.45”

4000

65

Coated

1/12

M110/E

3300

2100

10000

5.45”

3700

70

G12

1,11,18 CDM150/U/830/MED

Pulse Start Metal Halide
50 WATT
ED17 Med.

108228

1,12,13,18 MH50/U/MED/PS

108232

X 1,12,13,18 MH50/C/U/MED/PS

108246

1,12,13,18 MH70/U/MED/PS

Clear

1/12

M98/E

5600

3700

15000

5.45”

4000

65

108248

1,12,13,18 MH70/C/U/MED/PS

Coated

1/12

M98/E

5300

3400

15000

5.45”

3700

70

108254

1,12,13,18 MH100/U/MED/PS

Clear

1/12

M90/E

9000

5900

15000

5.45”

4000

65

108256

1,12,13,18 MH100/C/U/MED/PS

Coated

1/12

M90/E

8500

5500

15000

5.45”

3700

70

60003

1,12,13,18 MH100/U/MOG/PS

Clear

1/12

M90/E

9000

5900

15000

8.25”

4000

65

60007

1,12,13,14,18 MH125/HBU/MED/PS

Horizontal
Base Up

1/12

M150/E

12000

8400

15000

5.45”

4000

65

108258

1,12,13,18 MH150/U/MED/PS

70 WATT
ED17 Med.

100 WATT
ED17 Med.

ED28 Mog.

125 WATT
ED17 Med.

150 WATT
ED17 Med.

Clear

1/12

M102/E

14000

10500

15000

5.45”

4000

65

1/12

M102/E

14000

10500

15000

8.25”

4000

65

108305

1,4,12,13,14,18 MH150/U/PS

Clear

ED17 Med.

60002

1,4,12,13,14,18 MH175/BU/MED/PS

Clear Base Up

1/12

M152/E
M137/E

17500

14000

15000

5.45”

4000

65

ED28 Mog.

108274

1,4,12,13,16,18 MH175/BU/PS

Clear Base Up

1/12

17500

14000

15000

8.25”

4000

65

Horizontal
Base Up

M152/E
M137/E

1/12

M152/E
M137/E

15000

10700

15000

8.25”

4000

65

Clear Base Up

1/12

M136/E

21000

16800

15000

8.25”

4000

65

Coated Base Up

1/12

M136/E

20000

16000

15000

8.25”

3700

70

ED28 Mog.

175 WATT

60008

1,12,13,14,18 MH175/HBU/PS

200 WATT
ED28 Mog.

108284

1,4,12,13,14,18 MH200/BU/PS

60006

X 1,4,12,13,14,18 MH200/C/BU/PS

HID lamp symbols, footnotes and abbreviations are located on pages 111-114.

96

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HID LAMPS
Metal Halide
ED28

Bulb

Base

ED37

Product
Number

BT37

Footnotes

ED17

Product
Code

Description

Pkg.
Qty.

ANSI

Initial
Mean
Lumens Lumens

Avg.
Life

MOL

Color
Temp.

CRI

Pulse Start Metal Halide continued
250 WATT
ED28 Mog.

108276

1,4,12,13,14,18 MH250/BU/PS

Clear Base Up

1/12

M153/E
M138/E

25000

20000

15000

8.25”

4000

65

60005

1,4,12,13,14,18 MH250/C/BU/PS

Coated Base Up

1/12

M153/E
M138/E

23800

19000

15000

8.25”

3700

70

Horizontal
Base Up

1/12

M153/E
M138/E

21000

15000

15000

8.25”

4000

65

Clear Base Up

1/12

M154/E
M132/E

33000

26000

20000

8.25”

4000

65

Coated Base Up

1/12

31000

25000

20000

8.25”

3700

70

Clear Horizontal
Base Up

M154/E
M132/E

1/12

M154/E
M132/E

31000

23000

15000

8.25”

4000

65

Clear Base Up

1/6

M131/E

37000

29000

20000 11.50” 4000

65

60009

1,12,13,14,18 MH250/HBU/PS

320 WATT
ED28 Mog.

108278

1,4,6,12,13,14,18 MH320/BU/PS

60004

X 1,4,6,12,13,14,18 MH320/C/BU/PS

60010

1,12,13,14,18 MH320/HBU/PS

350 WATT
ED37 Mog.

108291

1,4,6,12,13,14,18 MH350/BU/PS

400 WATT
ED28 Mog.

60012

1,6,12,13,18 MH400/U/ED28/PS

Clear

1/12

M155/E
M135/E

39000

33000

20000

4000

65

ED37 Mog.

60011

1,6,12,13,18 MH400/U/PS

Clear

1/6

M155/E
M135/E

39000

35000

20000 11.50” 4000

65

Clear Base Up

1/6

M155/E
M135/E

44000

35000

20000 11.50” 4000

65

108280

1,4,5,6,12,13,14,18 MH400/BU/PS

750 WATT
ED37 Mog.

8.25”

60016

1,12,13,18 MH750/HBU/PS

Clear Horizonal
Base Up

1/6

M149/E

75000

55000

10000 11.50” 4000

65

60014

1,12,13,18 MH875/U/PS

Clear

1/6

M166/E

96000

82500

15000 11.50” 4000

65

60015

1,12,13,18 MH1000/U/PS

Clear

1/6

M141/E

110000 96000

15000 11.50” 4000

65

875 WATT
BT37 Mog.

1000 WATT
BT37 Mog.

Protected Metal Halide
50 WATT
ED17 Med.

108266

3,12,13,18 MP50/U/MED/PS

Clear

1/12

M110/O

3300

2100

10000

5.45”

4000

65

60505

3,12,13,18 MP50/C/U/MED/PS

Coated

1/12

M110/O

3200

2000

10000

5.45”

3700

70

108268

3,12,13,18 MP70/U/MED/PS

Clear

1/12

M98/O

5300

3400

12000

5.45”

4000

65

60508

3,12,13,18 MP70/C/U/MED/PS

Coated

1/12

M98/O

5000

3300

12000

5.45”

3700

70

108270

3,12,13,18 MP100/U/MED/PS

Clear

1/12

M90/O

8500

5500

15000

5.45”

4000

65

60507

3,12,13,18 MP100/C/U/MED/PS

Coated

1/12

M90/O

8100

5300

15000

5.45”

3700

70

108272

3,12,13,18 MP150/U/MED/PS

Clear

1/12

M102/O

13300

10000

15000

5.45”

4000

65

60503

3,12,13,18 MP150/C/U/MED/PS

Coated

1/12

M102/O

12600

9500

15000

5.45”

3700

70

70 WATT
ED17 Med.

100 WATT
ED17 Med.

150 WATT
ED17 Med.

HID lamp symbols, footnotes and abbreviations are located on pages 111-114.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 97

HID LAMPS
Metal Halide
ED17

Bulb

Product
Number

Base

Footnotes

Product
Code

ED28

ED37

Pkg.
Qty.

ANSI

1/12

M57/O

14000

Clear CoverShield

1/12

M57/O

Clear Base Up

1/12

Clear Base Up
CoverShield®

BT37

Avg.
Life

MOL

Color
Temp.

CRI

9100

10000

5.45”

4000

65

14000

9100

10000

5.45”

4000

65

M57/O

14000

9100

10000

8.25”

4000

65

1/12

M57/O

14000

9100

10000

8.25”

4000

65

Clear Base Up

1/12

M136/O

20000

16000

15000

8.25”

4000

65

Coated Base Up

1/12

M136/O

19000

15200

15000

8.25”

3700

70

M58/O

21800

14200

10000

8.25”

4000

65

Description

Initial
Mean
Lumens Lumens

BT56

Protected Metal Halide continued
175 WATT
ED17 Med.

108282
90402

ED28 EX39

108286
90400

3,12,13 MP175/U/MED
X 3,12,13,14,25 MP175/U/MED/CSTF
3,12,14,16 MP175/BU
X 3,12,13,14,25 MP175/BU/CSTF

Clear
®

200 WATT
ED28 EX39

60511

3,12,13,14,16,18 MP200/BU/PS

60509

X 3,12,13,14,16,18 MP200/C/BU/PS

250 WATT
ED28 EX39

108288

3,12,14,16 MP250/BU

Clear Base Up

1/12

60710

3,12,14,16 MP250/C/BU

Coated Base Up

1/12

M58/O

20000

13000

10000

8.25”

3700

70

23800

19000

15000

8.25”

4000

65

108298

3,12,13,14,16,18 MP250/BU/PS

Clear Base Up

1/12

M153/O
M138/O

60510

3,12,13,14,16,18 MP250/C/BU/PS

Coated Base Up

1/12

22600

17600

15000

8.25”

3700

70

90401

X 3,12,13,14,25 MP250/BU/CSTF

Clear Base Up
CoverShield®

M153/O
M138/O

1/12

M58/O

21800

14200

10000

8.25”

4000

65

8.25”

320 WATT
ED28 EX39

108290

3,4,6,12,13,14,18 MP320/BU/PS

Clear Base Up

1/12

M154/O
M132/O

31000

25000

20000

4000

65

108292

$ 3,6,7,12,14,16,24 MP360/BU/ES

Clear Base Up
Energy Saver

1/6

M165/O
M59/O

36000

23500

20000 11.50” 4000

65

M59/O

36000

23500

20000 11.50” 4000

65

360 WATT
ED37 EX39

400 WATT
ED37 EX39

108294

3,6,12,14,16 MP400/BU

Clear Base Up

1/6

60700

3,6,12,14,16 MP400/C/BU

Coated Base Up

1/6

M59/O

34000

22000

20000 11.50” 3700

70

Clear Base Up

1/6

41000

33000

20000 11.50” 4000

65

Clear Base Up
CoverShield®

M155/O
M135/O

1/6

M59/O

36000

23500

20000 11.50” 4000

65

108296
60502

3,4,5,6,12,13,14,18 MP400/BU/PS
3,6,12,14,16,25 MP400/BU/CSTF

450 WATT
ED37 EX39

60512

X 3,6,12,13,14,18 MP450/BU/PS

Clear Base Up

1/6

M144/O

47000

35000

20000 11.50” 4000

65

60513

X 3,6,12,13,14,18 MP575/BU/PS

Clear Base Up

1/6

M178/O

60000

45000

20000 11.50” 4000

65

60501

3,4,12,14,18 MP750/BU/PS

Clear Base Up

1/6

M149/O

72000

52000

10000 11.50” 4000

65

60514

3,6,12,13,14,18 MP875/BU/PS

Clear Base Up

1/6

M166/O

95000

72000

20000 11.50” 4000

65

60720

3,12,13,14,18 MP1000/BU

Clear Base Up

1/6

M47/O

110000 88000

10000 15.40” 4000

65

575 WATT
BT37 EX39

750 WATT
BT37 EX39

875 WATT
BT37 EX39

1000 WATT
BT56 EX39

HID lamp symbols, footnotes and abbreviations are located on pages 111-114.

98

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HID LAMPS
Metal Halide
ED17

Bulb

Base

ED28

Product
Number

T15

Footnotes

BT37

Product
Code

BT56

ED37

ED18

Description

Pkg.
Qty.

ANSI

Initial
Mean
Lumens Lumens

Clear Major

1/20

M90/E

8500

Avg.
Life

MOL

Color
Temp.

CRI

4675

12000

5.43”

4000

65

Standard Metal Halide
100 WATT
ED17 Med.

64818

1,12,16,20,21 MH100UMED/M

108262

1,12,16,20,21 MH175/U/MED

Clear

1/12

M57/E

15000

9100

10000

5.45”

4000

65

1,12,16,20,21 MH175/C/U/MED

Coated

1/12

M57/E

14800

8600

10000

5.45”

3700

70

175 WATT
ED17 Med.

108264
ED28 Mog.

108200

1,12,16,20,21 MH175/U

Clear

1/12

M57/E

15200

9100

10000

8.25”

4000

65

108202

1,12,16,20,21 MH175/C/U

Coated

1/12

M57/E

14800

8600

10000

8.25”

3700

70

108204

1,12,16,20,21 MH250/U

Clear

1/12

M58/E

21000

13700

10000

8.25”

4000

65

108206

1,12,16,20,21 MH250/C/U

Coated

1/12

M58/E

20000

13000

10000

8.25”

3700

70

Clear
CoverShield®

1/12

M58/E

21000

13700

10000

8.25”

4000

65

250 WATT
ED28 Mog.

ED28 Mog.
POMB

T15

Mog.

108604

1,12,16,20,21,25 MH250/U/CSTF

60303

X 1,8,12,16,18 MH250/HOR

Clear Horizontal

1/12

M58/E

23000

15000

10000

8.25”

4000

65

60302

X 1,8,12,16,18 MH250/C/HOR

Coated Horizontal 1/12

M58/E

22000

14300

10000

8.25”

3700

70

108220

1,12,16,20,21 MH250/HBU/T15

Clear Horizontal
Base Up

1/12

M58/E

21000

14500

10000

8.30”

4000

65

Clear Base Up
Energy Saver

1/6

M165/E
M59/E

36000

23000

20000 11.50” 4000

65

360 WATT
ED37 Mog.

108212 $ 1,6,7,8,12,14,16,24 MH360/BU/ES

400 WATT
BT37 Mog.

64450

1,6,12,15 MS400/BU

Clear Base Up
Major

1/6

M59/E

42000

27000

20000 11.50” 4000

65

ED18 Mog.

108218

1,6,12,15 MH400/HBU/ED18

Clear Horizontal
Base Up

1/12

M59/E

36000

23000

20000

9.75”

4000

65

ED28 Mog.

108216

1,6,12,16,20,21 MH400/U/ED28

Clear

1/12

M59/E

36000

23000

20000

8.25”

4000

65

60201

1,6,12,16,20,21 MH400/C/U/ED28

Coated

1/12

M59/E

34000

22000

20000

8.25”

3700

70

108208

1,6,12,16,20,21 MH400/U

Clear

1/6

M59/E

36000

23000

20000 11.50” 4000

65

108210

1,6,12,16,20,21 MH400/C/U

Coated

1/6

M59/E

34000

22000

20000 11.50” 3700

70

Clear
CoverShield®

1/6

M59/E

36000

23000

20000 11.50” 4000

65

ED37 Mog.

108600

1,6,12,16,20,21,25 MH400/U/CSTF

60301

X 1,6,8,12,16,18 MH400/C/HOR

Coated Horizontal

1/6

M59/E

36800

23900

20000 11.50” 3700

70

BT37 Mog.

108226

1,12,16,20,21,18 MH1000/U/BT37

Clear

1/6

M47/E

110000 71000

12000 11.50” 4000

65

BT56 Mog.

108222

1,12,16,20,21,18 MH1000/U

Clear

1/6

M47/E

110000 71000

12000 15.40” 4000

65

Clear Base Up/
Horizontal Major

1/6

M48/E

165000 140000

3000

15.40” 3900

65

Clear Base Up

1/6

M48/E

161000 136000

3000

15.40” 3400

65

POMB

1000 WATT

1500 WATT
BT56 Mog.

837405
108214

1,12,15 MH1500/HBU
1,12,14,18 MH1500/BU

HID lamp symbols, footnotes and abbreviations are located on pages 111-114.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 99

HID LAMPS
Metal Halide
T6/T7
G12

T8
FC2

Bulb

Base

Product
Number

Footnotes

Product
Code

Description

T6/T7
R7S

BT37

T15/T16

Pkg.
Qty.

ANSI

Initial
Mean
Lumens Lumens

BT56

Avg.
Life

MOL

Color
Temp.

CRI

Single Ended Metal Halide
70 WATT
T6

G12

108434

1,2,11,12,18,23 MH70SE/UVS/3K

Clear UV-Stop

1/24

M85/E

5600

3600

10000

4.30”

3200

70

108428

1,2,11,12,18,23 MH70SE/UVS/4K

Clear UV-Stop

1/24

M85/E

5600

3600

10000

4.30”

4200

70

108430

1,2,11,12,18,23 MH150SE/UVS/3K

Clear UV-Stop

1/24

M81/E

14000

10500

10000

4.30”

3200

65

108432

1,2,11,12,18,23 MH150SE/UVS/4K

Clear UV-Stop

1/24

M81/E

14000

10500

10000

4.30”

4200

65

150 WATT
T7

G12

Double Ended Metal Halide
70 WATT
T6

R7S

108402

1,2,12,18,23 MH70DE/UVS/3K

Clear UV-Stop

1/24

M85/E

5600

3400

10000

4.65”

3000

70

108400

1,2,12,18,23 MH70DE/UVS/4K

Clear UV-Stop

1/24

M85/E

5600

3600

10000

4.65”

4000

70

108408

X 1,2,12,18,23 MH100DE/UVS/3K

Clear UV-Stop

1/24

M91/E

8000

4680

10000

4.65”

3000

70

108406

X 1,2,12,18,23 MH100DE/UVS/4K

Clear UV-Stop

1/24

M91/E

8000

5200

10000

4.65”

4000

70

108412

X 1,2,12,18,23 MH150DE/UVS/3K

Clear UV-Stop

1/24

M81/E

12000

8400

10000

5.37”

3000

70

Clear

1/24

M80/E

20000

13000

8000

6.42”

4200

70

100 WATT
T7

R7S

150 WATT
T7

R7S

250 WATT
T8

FC2

108414

1,12,18,23 MH250DE/4K

Color Metal Halide
150 WATT
T7

R7S

108422

X 1,2,12,18,23 MH150DE/UVS/BDX

Blue UV-Stop

1/24

M81/E

-

-

8000

3.37”

-

-

108424

X 1,2,12,18,23 MH150DE/UVS/GDX

Green UV-Stop

1/24

M81/E

-

-

8000

3.37”

-

-

108426

X 1,2,12,18,23 MH150DE/UVS/MDX

Magenta UV-Stop

1/24

M81/E

-

-

8000

3.37”

-

-

400 WATT
BT37 Mog.

61001

X 1,13,17,21,19 MH400/BU/BDX

Blue

1/6

M59/E

-

-

5000

11.50”

-

-

61002

X 1,13,17,21,19 MH400/BU/GDX

Green

1/6

M59/E

-

-

5000

11.50”

-

-

61004

X 1,12,16,20,18 MH1000/BU/BDX

Blue

1/6

M47/E

-

-

5000

15.37”

-

-

Clear UV-Stop

1/24

M81/E

9000

-

8000

5.37” 10000

80

Clear

1/12

M59/E

25000

-

10000

9.76” 10000

90

1000 WATT
BT56 Mog.

Aquarium Metal Halide
150 WATT
T7

R7S

108420

X 1,2,12,18 MH150DE/UVS/10K

400 WATT
T15

Mog.

108416

1,12,18 MH400/U/T15/10K

HID lamp symbols, footnotes and abbreviations are located on pages 111-114.

100

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HID LAMPS
High Pressure Sodium
ED17

Bulb

Base

ED23.5

Product
Number

ED18

Footnotes

ED28

Product
Code

ED25

Description

Pkg.
Qty.

ANSI

Initial
Mean
Lumens Lumens

Avg.
Life

MOL

Color
Temp.

CRI

Clear

1/12

S76

2200

1980

24000

5.45”

2000

20

Diffused

1/12

S76

2000

1800

24000

5.45”

2000

20

Clear

1/12

Diffused

S68

3800

3420

24000

5.45”

2000

20

1/12

S68

Clear

3400

3060

24000

5.45”

2000

20

1/12

S68

3800

3420

24000

7.75”

2000

20

Diffused

1/12

S68

3400

3060

24000

7.75”

2000

20

High Pressure Sodium
35 WATT
ED17 Med.

108102
108103

10,13,15 LU35/MED/ECO
X 10,13,15 LU35/MED/D

50 WATT
ED17 Med.

ED23.5 Mog.

108104

10,13,15 LU50/MED/ECO

108105

X 10,13,15 LU50/MED/D

208120

10,13,15 LU50/ECO

208121

X 10,13,15 LU50/D

70 WATT
ED17 Med.

108106

10,13,15 LU70/MED/ECO

Clear

1/12

S62

6000

5400

24000

5.45”

2000

20

ED23.5 Mog.

208122

10,13,15 LU70/ECO

Clear

1/12

S62

6000

5400

24000

7.75”

2000

20

Diffused

1/12

S62

5500

4950

24000

7.75”

2000

20

Clear

1/12

S54

9000

8100

24000

5.45”

2000

20

Diffused

1/12

S54

8100

7290

24000

5.45”

2000

20

Clear

1/12

S54

9000

8100

24000

7.75”

2000

20

Diffused

1/12

S54

8100

7290

24000

7.75”

2000

20

Clear

1/12

S55

15000

13500

24000

5.45”

2000

20

Diffused

1/12

S55

13500

12150

24000

5.45”

2000

20

208123

X 10,13,15 LU70/D

100 WATT
ED17 Med.

ED23.5 Mog.

108108

10,13,15 LU100/MED/ECO

108109

X 10,13,15 LU100/MED/D

208124

10,13,15 LU100/ECO

208125

X 10,13,15 LU100/D

150 WATT
ED17 Med.

ED23.5 Mog.
ED28 Mog.

108110

10,13,15 LU150/MED/ECO

108111

X 10,13,15 LU150/MED/D

208126

10,13,15 LU150/ECO

Clear

1/12

S55

15000

13500

24000

7.75”

2000

20

64002

10,13,15 LU150/100/ECO

Clear

1/12

S55

15000

13500

24000

8.98”

2000

20

208128

10,13,15 LU200/S66/ECO

Clear

1/12

S66

22000

19800

24000

9.75”

2000

20

208130

10,13,15 LU250/ECO

Clear

1/12

S50

28000

25200

24000

9.75”

2000

20

208132

10,13,15 LU400/ECO

Clear

1/12

S51

48000

43200

24000

9.75”

2000

20

279547

10,13,15 LU1000/ECO

Clear

1/6

S52

130000 117000 24000 15.08” 2000

20

200 WATT
ED18 Mog.

250 WATT
ED18 Mog.

400 WATT
ED18 Mog.

1000 WATT
ED25 Mog.

HID lamp symbols, footnotes and abbreviations are located on pages 111-114.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 101

HID LAMPS
High Pressure Sodium
ED23.5

Bulb

Base

Product
Number

Footnotes

Product
Code

Description

Pkg.
Qty.

ANSI

Initial
Mean
Lumens Lumens

Avg.
Life

MOL

Color
Temp.

CRI

High Pressure Sodium Non-Cycling
70 WATT
ED23.5 Mog.

64500

 10,13,15 LU70/NC

Clear Non-Cycling 1/12

S62

6300

5670

20000

7.75”

2000

>20

64502

 10,13,15 LU100/NC

Clear Non-Cycling 1/12

S54

10500

9500

20000

7.75”

2000

>20

64504

 10,13,15 LU150/NC

Clear Non-Cycling 1/12

S55

16000

14400

20000

7.75”

2000

>20

64506

 10,13,15 LU250/NC

Clear Non-Cycling 1/12

S50

32000

28800

20000

9.75”

2000

>20

100 WATT
ED23.5 Mog.

150 WATT
ED23.5 Mog.

250 WATT
ED23.5 Mog.

High Pressure Sodium Stand-By
70 WATT
ED23.5 Mog.

64501

 10,13,15 LU70/SBY/LL

Clear Stand-by
Twin Arc Tube

1/12

S62

6000

5670

48000

7.75”

2000

>20

64503

 10,13,15 LU100/SBY/LL

Clear Stand-by
Twin Arc Tube

1/12

S54

9600

8600

48000

7.75”

2000

>20

208402

 10,13,15 LU150/SBY/LL

Clear Stand-by
Twin Arc Tube

1/12

S55

15000

13500

48000

7.75”

2000

20

64505

 10,13,15 LU200/SBY/LL

Clear Stand-by
Twin Arc Tube

1/12

S66

22000

19800

48000

9.75”

2100

>20

64507

 10,13,15 LU250/SBY/LL

Clear Stand-by
Twin Arc Tube

1/12

S50

28000

25200

48000

9.75”

2000

>20

208400

10,13,15 LU400/SBY/LL

Clear Stand-by
Twin Arc Tube

1/12

S51

48000

43200

48000

9.75”

2000

20

Clear Stand-by
Twin Arc Tube

1/12

S51

53500

48000

20000

9.75”

2000

>20

100 WATT
ED23.5 Mog.

150 WATT
ED23.5 Mog.

200 WATT
ED23.5 Mog.

250 WATT
ED23.5 Mog.

400 WATT
ED23.5 Mog

64508

 10,13,15 LU400/NC

HID lamp symbols, footnotes and abbreviations are located on pages 111-114.

102

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HID LAMPS
Mercury Vapor
ED37

Bulb

Base

ED17

Product
Number

ED23.5

Footnotes

ED28

Product
Code

BT56

R40

Description

Pkg.
Qty.

ANSI

Initial
Mean
Lumens Lumens

Avg.
Life

MOL

Color
Temp.

CRI

Mercury Vapor
50 WATT
108302

17,19,21 MV50DX

Deluxe White

1/12

H46

1600

1280

6000

5.45”

4000

45

108304

17,21 MV75DX

Deluxe White

1/12

H43

2700

2250

12000

5.45”

4000

45

ED17 Med.

108306

17,21 MV100DX

Deluxe White

1/12

H38

4600

3600

24000

5.45”

4000

45

ED23.5Mog.

108308

17,21 MV100DXMOG

Deluxe White

1/12

H38

4600

3600

24000

7.50”

4000

45

Clear

1/12

H39

7800

7250

24000

8.50”

5800

25

Deluxe White

1/12

H39

8500

6900

24000

8.50”

4000

45

Clear

1/12

H37

12800

10535

24000

8.50”

5800

25

Deluxe White

1/12

H37

13500

11100

24000

8.50”

4000

45

Clear

1/6

H33

22000

18900

24000 10.38” 5800

25

1/6

H33

23000

19100

24000 10.38” 4000

45

ED17 Med.

75 WATT
ED17 Med.

100 WATT

175 WATT
ED28 Mog.

108332

21 MV175CL

108310

17,21 MV175DX

108334

21 MV250CL

108312

17,21 MV250DX

108336

21 MV400CL

250 WATT
ED28 Mog.

400 WATT
ED37 Mog.

108314

17,21 MV400DX

Deluxe White

869331

9,17,21 MV1000DX

Deluxe White
Major

1/6

H36

58000

48500

24000 15.38” 4000

45

1000 WATT
BT56 Mog.

Mercury Vapor Reflector
100 WATT
R40

Med.

108350

17 MV100DX/R40

Deluxe White
Reflector

1/12

H38

2450

2000

16000

6.89”

5800

45

108356

17 MV175DX/R40

Deluxe White
Reflector

1/12

H39

6200

4900

24000

6.89”

5800

45

175 WATT
R40

Med.

HID lamp symbols, footnotes and abbreviations are located on pages 111-114.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 103

HID LAMPS
Bulb and Base Identification Guide
Bulb Shapes

BT37

BT56

T4
G8.5

T4
GU6.5

MR16
GX10

ED17

PAR20/PAR30L

ED18

ED23.5

PAR38

ED25

R40

ED28

T6/T7/T8
Double
Ended
Rx7S

ED37

T6/T7
Single
Ended
G12

T15/
T16

Base Types

FC2

GX10

GU6.5

104

TOC

G8.5

POMB
Position Oriented
Mogul Base

R7S/Rx7s
Recessed
Single Contact

EX39
Exclusionary
Mogul Base

G12
Medium
Bi-Bin

E39
Mogul

E26/27
Medium

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HID LAMPS
Cross Reference Guide
HALCO

G.E.

PHILIPS

OSRAM/SYLVANIA

ANSI

CDM

CMH®

MasterColor®

Powerball®

CDM20/MR16NFL/830/GX10 CMH20/MR16/830/FL

-

-

C156

CDM20/P20/FL/830

CMH20/PAR20/FL

-

-

C156

CDM20/P20/SP/830

CMH20/PAR20/SP

-

-

C156

CDM20/T6/830

CMH20/T/U/G12

-

-

C156/E

CDM20/TC/830

CMH20/TC/U/830/G8.5

-

MC20TC/U/G8.5/830

C156/E

CDM20/TC/830/GU6.5

CMH20/TC/U/830/GU6.5

-

-

C/M-130/E

CDM35/P20/SP/830

CMH39/PAR20/830/SP10

CDM35/PAR20/M/SP3K

MCP39PAR20/U/830/SP

C/M-130/O

CDM35/P20/FL/830

CMH39/PAR20/830/FL30

CDM35/PAR20/M/FL3K

MCP39PAR20/U/830/FL

C/M-130/O

CDM35/P30L/SP/830/M

CMH39/PAR30L/830/SP10

CDM35/PAR30L/M/SP

MCP39PAR30LN/U/830/SP

C/M-130/O

CDM35/P30L/FL/830

CMH39/PAR30L/830/FL25

CDM35/PAR30L/M/FL

MCP39PAR30LN/U/830/FL

C/M-130/O

CDM35/T6/830

CMH39/T/U/830/G12

CDM35/T6/830

MC39T6/U/G12/830

C/M-130/E

CDM35/TC/830

CMH39/TC/U/830/G8.5

CDM35/TC/830

MC39TC/U/G8.5/830

C/M-130/E

CDM35/TC/830/GU6.5

-

CDM35/TC/830/GU6.5

-

C/M-130/E

CDM35/TD/830

-

CDM70/TD/830

-

C/M-130/E

CDM70/P30L/SP/830

CMH70/PAR30L/830/SP15

CDM70/PAR30L/M/SP

MCP70PAR30LN/U/830/SP

C/M-98/O | C/M-139/O

CDM70/P30L/FL/830

CMH70/PAR30L/830/FL40

CDM70/PAR30L/M/FL

MCP70PAR30LN/U/830/FL

C/M-98/O |C/M-139/O

CDM70/P30L/SP/942

-

CDM70/PAR30L/M/SP/4K

-

C/M-98/O | C/M-139/O

CDM70/P30L/FL/942

-

CDM70/PAR30L/M/FL/4K

-

C/M-98/O | C/M-139/O

CDM70/P38/SP/830

CMH70/PAR38/830/SP15

CDM70/PAR38/M/SP

-

C/M-98/O | C/M-139/O

CDM70/P38/FL/830

CMH70/PAR38/830/FL25

CDM70/PAR38/M/FL

-

C/M-98/O | C/M-139/O

CDM70/P38/FL/942

-

CDM70/PAR38/M/FL/4K

-

C/M-98/O | C/M-139/O

CDM70/T6/830

-

CDM70/T6/830

-

C/M-98/E | C/M-139/E

CDM70/T6/942

-

CDM70/T6/942

-

C/M-98/E | C/M-139/E

CDM70/TC/830

CMH70/TC/U/830/G8.5

CDM70/TC/830

MC70TC/U/G8.5/830

C/M-98/E | C/M-139/E

CDM70/TD/830

CMH70/TD/830/RX7s

CDM70/TD/830

MC70T6/DE/830

CDM70/U/830/MED

CMH70/C/U/830/MED/O

MHC70/C/U/M/3K/ALTO

MCP70/C/U/MED/830

CDM100/P38/FL/830/M

CMH100/PAR38/830/FL25

CDM100/PAR38/FL/3K/ALTO

MCP100PAR38/U/FL/830/ECO

M90/O | M140/O

CDM100/P38/SP/830/M

CMH100/PAR38/830/SP15

CDM100/PAR38/SP/3K/ALTO

MCP100PAR38/U/SP/830/ECO

M90/O | M140/O

CDM150/T6/830

CMH150/T/U/830/G12

CDM150/T6/830

MC150T6/U/G12/830

CDM150/T6/942

CMH150/T/U/942/G12

CDM150/T6/942

MC150T6/U/G12/942

CDM150/TD/830

CMH150/TD/830/Rs7s

CDM150/TD/830

MC150T6/DE/830

CDM150/U/830/MED

CHM150/U/830/MED/O

MHC150/U/MP/3K/ALTO

MCP150/U/MED/830

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

M85/E | C/M-139/E
C/M-98/E | C/M-139/E

C/M-102/E | C/M-142/E
C/M-102/E | C/M-142/E
M81/E | C/M-102/E | C/M-142/E
C/M-102/E | C/M-142/E

TOC 105

HID LAMPS
Cross Reference Guide
HALCO

G.E.

PHILIPS

OSRAM/SYLVANIA

Metal Halide

Multi-Vapor®

Metal Halide

Metalarc®

MH50/U/MED/PS

MXR50/U/MED/O

MH50/U/M

MP50/U/MED

M110/E

MH50/C/U/MED/PS

MXR50/C/U/MED

MH50/C/U/M

MP50/C/U/MED

M110/E

MH70/U/MED/PS

MXR70/U/MED

-

MP70/U/MED

M98/E

MH70/C/U/MED/PS

MXR70/C/U/MED

-

MP70/C/U/MED

M98/E

MH70DE/UVS/3K

ARC70/TD/UVC/730

CDM70/TD/830

HQI-DE70/WDX

M85/E

MH70DE/UVS/4K

ARC70/TD/UVC/743

MHN70/TD/840

HQI-DE70/NDX

M85/E

MH70SE/UVS/3K

CMH70/T/U/830/G12

CDM70/T6/830

-

M85/E

MH70SE/UVS/4K

CMH70/T/U/943/G12

CDM70/T6/942

-

M85/E

MH100/U/MED/PS

MXR100/U/MED

-

MP100/U/MED

M90/E

MH100/C/U/MED/PS

MXR100/C/U/MED

-

MP100/C/U/MED

M90/E

MH100/U/MOG/PS

-

-

-

M90/E

MH125/HBU/MED/PS

-

-

-

M150/E

MH150/U/MED/PS

MXR150/U/MED

MP150/U/MED

-

M102/E

MH150/U/PS

-

-

-

M102/E

MH150DE/UVS/10K

-

-

-

M81/E

MH150DE/UVS/3K

ARC150/TD/UVC/730

MHN150/TD/840

HQI-DE150/WDX

M81/E

MH150DE/UVS/4K

ARC150/TD/UVC/742

-

HQI-DE150/NDX

M81/E

MH150DE/UVS/BDX

-

-

-

M81/E

MH150DE/UVS/GDX

-

-

-

M81/E

MH150SE/UVS/3K

ARC150T/U/830G12

-

-

M81/E

MH150SE/UVS/4K

ARC150T/U/840G12

-

HQI-SE150/NDX

M81/E

MH175/BU/PS

MVR175/VBU/PA

MS175/BU/PS

MS175/PS/BU-ONLY

M152/E-M137/E

MH175/BU/MED/PS

MVR175/VBU/MED/PA

MS175/BU/PS

MS175/PS/BU

M152/E-M137/E

MH175/HBU/PS

MVR175/VBU/PA

-

-

M152/E-M137/E

MH175/U

MVR175/U

MH175/U

M175/U

M57/E

MH175/U/MED

MVR175/U/MED

MH175/U/M

M175/U/MED

M57/E

MH175/C/U

MVR175/C/U

MH175/C/U

M175/C/U

M57/E

MH175/C/U/MED

MVR175/C/U/MED

MH175/C/U/M

M175/C/U/MED

M57/E

MH200/BU/PS

-

-

MS200/PS/BU-ONLY/BT28

M136/E

MH200/C/BU/PS

-

-

MS200/C/PS/BU/BU-ONLY/BT28

M136/E

MH250/HBU/T15

-

-

-

M58/E

MH250/HBU/PS

MVR250/VBU/PA

MS250/BU/PS

MP250/PS/BU-ONLY

M153/E-M138/E

MH250/BU/PS

MVR250/VBU/PA

MS250/BU/PS

MP250/PS/BU-ONLY

M153/E-M138/E

MH250/C/BU/PS

MVR250/C/VBU/PA

-

MP250/C/PS/BU-ONLY

M153/E-M138/E

MH250/C/U

MVR250/C/U

MS250/C/U

M250/C/U

M58/E

MH250/U

MVR250/U

MH250/U

M250/U

M58/E

106

TOC

ANSI

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HID LAMPS
Cross Reference Guide
HALCO

G.E.

PHILIPS

OSRAM/SYLVANIA

ANSI

Metal Halide

Multi-Vapor®

Metal Halide

Metalarc®

MH250DE/4K

-

-

-

MH320/VBU/PS

MVR320/VBU/HO/PA

MS320/BU/PS

MS320/PS/BU

M154/E-M132/E

MH320/HBU/PS

MVR320/HOR/PA

MS320/PS/U

M320/PS/BU-HOR

M154/E-M132/E

MH320/BU/PS

MVR320/VBU/XHO/PS

MS320/U/PS

MP320/350/PS/BU-ONLY/BT28

M154/E-M132/E

MH320/C/BU/PS

MVR320/C/VBU/XHO/PS

MS320/C/U/PS

MS320/C/PS/BU-HOR

M154/E-M132/E

MH350/BU/PS

MVR350/VBU/XHO/PA

MS350/BU/PS

MP350/400/PS/BU-ONLY

MH360/BU/ES

MVR360/VBU/WM/HO

-

-

M165/E-M59/E

MH400/BU/PS

MVR400/VBU/HO/PA

MS400/BU/PS

MS400/PS/BU-ONLY

M155/E-M135/E

MH400/BU/LU

MVR400/VBR/R

-

-

S51/E

MH400/HBU/ED18

-

-

-

M59/E

MH400/U

MVR400/U

MH400/U

M400/U

M59/E

MH400/U/ED28

MVR400/U/ED28

MH400/U/ED28

M400/U/BT28

M59/E

MH400/U/ED28/PS

MVR400/HOR/ED28/PA

-

M400/PS/U/BT28

M155/E-M135/E

MH400/U/PS

MVR400/HOR/PA

MS400/HOR/PS

M400/PS/U

M155/E-M135/E

M80/E

M131/E

MH400/U/T15/10K

-

-

-

M59/E

MH400/C/U

MVR400/C/U

MH400/C/U

M400/C/U

M59/E

MH400/C/U/ED28

MVR400/C/U/ED28

MH400/U/ED28

M400/C/U/BT28

M59/E

MH450/BU/PS

-

-

-

M144/E

MH875/U/PS

-

-

-

M166/E

MH1000/U

MVR1000/U

MH1000/U

M1000/U

M47/E

MH1000/U/PS

MVR1000/U/BT37/PA

M1000/PS/U/BT37

MS1000/BU/BT37/PS

M141/E

MH1000/U/BT37

MVR1000/U/BT37

M1000/U/BT37

MH1000/U/BT37

M47/E

MH1500/BU

MVR1500/HBU

MH1500/U

M1500/BU-HOR

M48/E

MP50/C/U/MED/PS

MXR50/C/U/MED/O

-

MP50/C/U/MED

M110/O

MP50/U/MED/PS

MXR50/U/MED/O

-

MP50/U/MED

M110/O

MP70/C/U/MED/PS

MXR70/C/U/MED/O

-

MP70/C/U/MED

M98/O

MP100/U/MED/PS

MXR100/U/MED/O

-

MP100/U/MED

M90/O

MP150/U/MED/PS

MXR150/U/MED/O

-

MP150/U/MED

M102/O

MP150/C/U/MED/PS

MXR150/C/U/MED/O

MP150/C/U/MED

-

M102/O

MP175/BU

MPR175/VBU/O

MP175/BU

MP175/BU-ONLY

M57/O

MP175/BU/PS

MPR175/VBU/O

MP175/BU

MP175/BU-ONLY

M152/O-M137/O

MP175/U/MED

-

-

MP175/BU-ONLY/MED

M57/O

MP200/BU/PS

-

-

-

M136/O

MP200/C/BU/PS

-

-

-

M136/O

MP250/BU

MPR250/VBU/O

MP250/BU

MP250/BU-ONLY

M58/O

MP250/BU/PS

-

-

MP250/PS/BU-ONLY

M153/O-M138/O

MP250/C/BU

MPR250/C/VBU/O

-

MP250/C/BU-ONLY

M58/O

MP250/C/BU/PS

-

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

MP250/C/PS/BU-ONLY

M153/O-M138/O

TOC 107

HID LAMPS
Cross Reference Guide
HALCO

G.E.

PHILIPS

OSRAM/SYLVANIA

ANSI

Metal Halide

Multi-Vapor®

Metal Halide

Metalarc®

MP320/BU/PS

MPR320/VBU/XHO/PA

MP320/BU/PS

MP320/350/PS/BU-ONLY/BT28

M154/O-M132/O

MP320/C/BU/PS

MPR320/C/VBU/XHO/PA

MP320/C/BU/PS

MP320/350/C/PS/BU-ONLY/BT28

M154/O-M132/O

MP360/BU/ES

MPR360/VBU/WM/HO/O

MP360/BU/EW

MSP360/SS/BU-ONLY

M59/O or M165/O

MP400/BU

MVT400/VBU

MHT400/U

MPT400/BU

MP400/BU/PS

-

-

-

M155/O-M135/O

MP400/C/BU

MVT400/C/VBU

MHT400/C/U

MPT400/C/BU

M155/O-M135/O

MP450/BU/PS

-

-

-

M144/O

MP575/BU/PS

-

-

-

M178/O

MP750/BU/PS

-

-

MP750/BU/PS

M149/O

MP875/BU/PS

-

-

-

M166/O

MP1000/BU

MPR1000/VBU/O

MP1000/BU

MP100/BU-ONLY

M47/O

H.P.S.

Lucalox™

Ceramalux®

Lumalux®

LU35/MED/ECO

LU35/MED

C35S76/M

LU35/MED

S76

LU50/ECO

LU50

C50S68/ALTO

LU50/ECO

S68

LU50/MED/ECO

LU50/MED

C50S68/M

LU50/MED

S68

LU70/ECO

LU70

C70S62/ALTO

LU70/D

S62

LU70/MED/ECO

LU70/MED

C70S62/M

LU70/MED

S62

LU100/ECO

LU100/D

C100S54/ALTO

LU100/D

S54

LU100/MED/ECO

LU100/MED

C100S54/M

LU100/MED

S54

LU150/ECO

LU150/55/D

C150S55/M

LU150/55/D

S55

LU150/100/ECO

LU150/100

C150S56/ALTO

LU150/100

S56

LU150/MED/ECO

LU150/MED

C150S55/D/M

LU150/55/MED

S55

LU150/SBY/LL

LU150/55/SBY/XL

C150S55/2

LU150/55/SBY

S55

LU200/S66/EC0

LU200

C200S66/ALTO

LU200/ECO

S66

LU250/ECO

LU250/D

C200S50/ALTO

LU250/D

S50

LU400/ECO

LU400/D

C400S51/D/ALTO

LU400/D

S51

LU400/SBY/LL

LU400/SBY/XL

C400S51/2

LU400/SBY

S51

LU1000/ECO

LU1000

C1000S52/ALTO

LU1000

S52

MV1000DX

HR1000DX36

M36GW-1OOO/DX

H36GW-1000/DX

H36

MV100DX

HM100DX38/MED

H38MP-100/DX

H38AV-100/DX

H38

MV100DX/R40

HR100RDXFL38

H38BP-100/DX

H38BP-100/DX

H38

MV100DXMOG

HR100DX38

H38JA-100/DX

H38JA-100/DX

H38

MV175CL

HR174A39

H39KB-175

H39KB-175

H39

M59/O

Mercury Vapor

108

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HID LAMPS
Cross Reference Guide
HALCO

G.E.

PHILIPS

OSRAM/SYLVANIA

ANSI

MV175DX

HR175DX39

H39KC-175/DX

H39KC-175/DX

H39

MV175DX/R40

HR175RDXFL39

H39BP-175/DX

H39BP-175/DX

H39

MV250CL

HR250A37

H37KB-250

H37KB-250

H37

MV250DX

HR250DX37

H37KC250/DX

H37KC-250/DX

H37

MV400CL

HR400A33

H33CD-400

H33CD-400

H33

MV400DX

HR400DX33

H33GL-400/DX

H33GL-400/DX

H33

MV50DX

HR40/50DX45-46

H46DL-40-50/DX

H45/46DL-40/50/DX

H46

MV75DX

HR75DX43

H43AV-75/DX

H43AV-75/DX

H43

Mercury Vapor

– CMH, Multi-Vapor and Lucalox are registered trademarks of General Electric.
– MasterColor and Ceramalux registered trademarks of Philips.
– PowerBall, Metalarc, and Lumalux are registered trademarks of Osram/Sylvania.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 109

HID LAMPS
General Information and Warning Notices
Metal Halide and Mercury Vapor Lamp Warning:

R WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if outer envelope of the lamp is broken or
punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used.
Lamps that will automatically extinguish when the envelope is broken or punctured are commercially available.

Fixture Requirements-Lamp Enclosure Type

HID lamps have fixture requirements that have to be followed. The following codes identify the appropriate fixture for a particular lamp.
O = Open or Enclosed Fixtures
E = Enclosed Fixtures Only

Use in Enclosed Fixtures

“Enclosed” fixture means a fixture properly enclosed and designed to contain fragments of hot glass (up to 1100°C) per UL Standard #1598.
If uncertain, contact the fixture manufacturer for more details.

Use in Open Fixtures

For lamps operated in the vertical position ±15° that are not designed for “Enclosed Fixtures Only” may be used in either open or enclosed fixtures
depending on the environment and application. For instance, if the lamp is positioned by flammable material or in an unoccupied area for extended periods,
an enclosed fixture which can contain fragments of hot quartz or glass is recommended.

Protection of Bulbs from Moisture

The outer glass envelope of HID lamps are made of heat-resistant glass, designed to have both strength and thermal-shock-resistant characteristics
appropriate for standard applications in typical luminaries. Nevertheless, it is necessity to provide shielding for lamps to avoid bulb breakage that may
result from direct contact with liquids during operation.

Metal Halide Lamps

Fixture lens/diffuser material must be able to hold fragments of hot glass (up to 1100°C). If you do not know whether or not the fixture can safely
withstand an arc tube rupture, contact fixture manufacturer. In continuously operating systems (24/7), turn lamps off once per week for 15 minutes.
FAILURE TO DO SO INCREASES THE RISK OF RUPTURE. Fixture should be relamped at or before the lamp’s end of rated life. Light output diminishes
while energy consumption and risk of rupture increase.

High Pressure Sodium Lamps

This is a vacuum jacket and may implode if broken. As a safety measure, wear safety glasses and gloves when installing or removing lamps.
High Pressure Sodium lamps are not position-sensitive and can be operated in any burning position.

Mercury Lamps

Fixture lens/diffuser material must be capable of containing fragments of hot glass (up to 1100°C). If you do not know whether your fixture can withstand an
arc tube rupture, contact your fixture manufacturer. Relamp fixtures at or before the end of rated life; beyond rated life, light output diminishes while energy
consumption and risk of rupture increases. Mercury lamps are not position-sensitive and may be operated in any burning position.

Starting Characteristics

When power is applied, full light does not occur instantaneously, there is a time delay for the lamp to reach 90% total light output.
The delay time for Metal Halide is approximately 2-5 minutes, 3-4 minutes for High Pressure Sodium and 5-7 minutes for Mercury Vapor.

Lumens Listed are Reference Lumens

The rated average lamp lumen is obtained under controlled laboratory conditions in a set burning position.Initial Reference Lumens refer to the lamp lumen
output after burning for 100 hours. Mean Reference Lumens refer to the lamp lumen output at the mean lumen point during lamp life. The mean lumen point
occurs at 50% rated life for HPS and Mercury Vapor lamps, and at 40% rated life for Metal Halide lamps.

Rated Life

Values based on laboratory tests of a large quantity of representative lamps under controlled conditions, including operation at 10 hours per start on ballasts
having specific electrical characteristics. Individual or groups of lamps may vary from the Rated Life given. Lamp operating conditions may also influence life.
Where Rated Life is less than 24,000 hours, it is a MEDIAN value or life expectancy; the total operating time at which, under normal operating conditions, 50%
of any group of originally installed lamps is expected to be still burning. At burning cycles shorter than 10 hours per start, the median life will shorten as follows:
5 hours start- approximate life of 75% of rating
2 ½ hours start - approximate life of 56% of rating
1 ¼ hours start - approximate life of 42% of rating

HID Color

The color temperature and CRI listed in the tables are for reference purposes only. All HID lamps display some amount of lamp-to-lamp color variation
and shift over life. These characteristics may increase depending on choice of fixture, ballast, burning position and ambient conditions. Color difference
may be greater than normal during the first 100 hours of burning.
110

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HID LAMPS
Symbols, Footnotes and Abbreviations
SYMBOLS
 New product introduced within the past year.
$ Energy saving product.
X Product will be discontinued when inventory is depleted.

FOOTNOTES
1 Lamps classified as E-type are used ONLY in suitably enclosed luminaries. See lamp warning.
2 UV-Stop Quartz filtered design.
3

Lamps classified as O-type comply with ANSI standard C78.387 for containment testing and may be used in open luminaries.
See lamp warning.

4 When operated on ballasts having a sustaining voltage less than 270 Volts, lamp life may be significantly reduced.
5 Lamps may be operated on ANSI M135 (400W) compliant ballasts.
6 20,000 average rated life based on 10 hrs/start. 30,000 average rated life based on 12 hrs/start.
7 Operates at 360 watts on 400 watt M59 ballast or M165 ballast.
8 Horizontally oriented lamps require a position oriented mogul (POM) socket to accept position oriented mogul base.
9 H34 and H36 lamps are not interchangeable.
10 Follow fixture manufacturer’s recommendations regarding proximity of ballast to lamp.
11 Supply voltage must be held to ±5 volts of rated supply voltage.
Color characteristics may vary somewhat from one lamp to another. Time should be allowed for lamp to stabilize in color when
it is turned on for the first time or if for any reason its operating position is changed. This may require several hours of operation,
12
with more than one start. Lamp color and output may change temporarily if the lamp is subjected to excess vibration or shock.
Lamp color characteristics may change after long accumulated operating time.
13 Use with 4000 Volt pulse-rated sockets only.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 111

HID LAMPS
Symbols, Footnotes and Abbreviations
FOOTNOTES
14 Performance may not be satisfactory unless operated within specified operating positions.
15

For use in fixtures that do not redirect a substantial portion of the energy toward the arc tube; otherwise very early failure
is anticipated.

Requires ballast that is designed to operate all popular brands of Metal Halide lamps. 1000W types will operate from H36
16 conventional lag type ballast for Mercury Vapor lamps at ambient temperatures of 50°F or higher. 1000W types must not
be operated at 1500W or higher.
17

It is a characteristic of phosphor-coated vapor lamps to require a few hundred hours of operation to gradually reach normal
characteristic color. New lamps may have a slight pink appearance during this initial operation period.

18 This product contains less than 120 nCi of Kr-85.
19 For 40W operation use H45 ballast.
20 Rated average life: vertical ±15°. Other positions 75% of rated life.
21 In general, horizontal lumens will be 5-10% lower than the vertical lumen values.
22 Use electrical ballast, peak lead ballast or system that can shut itself off if ballast overheating occurs.
23 Lamp will operate at 400 watts when used on a linear reactor ballast.
24 Do not operate in aviaries or around fowl or small animals.
This lamp meets ANSI specifications for T6 tube size as defined by ANSI C78.43-2007; nominal diameter for this item
25 is 0.75” with a maximum diameter of 1”. Halco 150W lamps have an outer glass diameter of 0.87” to increase arc tube
reliability. Please ensure fixture dimensions prior to ordering.

112

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HID LAMPS
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
/3K Suffix used to indicate Color Temperature of 3500K.
/4K Suffix used to indicate Color Temperature of 4000K or 4200K.
/10K Suffix used to indicate Color Temperature of 10,000K.
/BDX Suffix used to indicate a Blue ProLume® Metal Halide lamp.
BU Code abbreviation for Base Up Operating lamps.
C Code abbreviation for lamps with a Coated finish.
CDM Code abbreviation for Ceramic Metal Halide.
CL Code abbreviation for lamps with a Clear finish.
/CS Suffix used to indicate CoverShield® safety coated lamps.
/CSTF Suffix used to indicate CoverShield® safety coated lamps.
/D Suffix used to indicate Diffused lamps.
DE Code abbreviation for Double Ended Metal Halide lamps.
DX Code abbreviation for ProLume® Deluxe White Mercury Vapor lamps.
/ES Suffix used to indicate an Energy Saving Metal Halide lamp.
/FL Suffix used to indicate Flood lamps.
/GDX Suffix used to indicate a Green ProLume® Metal Halide lamp.
/HBU Suffix used to indicate Horizontal to Base Up Metal Halide lamps.
/HOR Suffix used to indicate Horizontal Metal Halide lamps.
/LL Suffix used to indicate lamps with a Long Life.
LU Code abbreviation for High Pressure Sodium lamps.
/LU Suffix used to indicate High Pressure Sodium to Metal Halide retrofit lamp.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 113

HID LAMPS
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
/M Suffix used to indicate Major brand HID lamps (GE, Philips, Osram/Sylvania).
/MDX Suffix used to indicate a Magenta ProLume® Metal Halide lamp.
MED Code abbreviation for Medium base type (E26/27).
MH Code abbreviation for Metal Halide lamps.
MHC Code abbreviation for Ceramic Metal Halide lamps.
MV Code abbreviation for Mercury Vapor lamps.
/MOG Suffix used to indicate a Mogul base lamp.
MP Code abbreviation for Protected Metal Halide lamps suitable for open fixture applications.
NC Suffix used to indicate Non-Cycling High Pressure Sodium lamps.
NFL Code abbreviation for Narrow Flood lamps.
/SBY Suffix used to indicate Stand-By Twin Arc Tube lamps.
SE Code abbreviation for Single Ended Metal Halide lamps.
/SP Suffix used to indicate Spot lamps.
TC Code abbreviation for T4 CDM lamps.
U Code abbreviation for Universal Metal Halide lamps.
/UVS Suffix used to indicate UV-Stop lamps.

114

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

®

HALOGEN LAMPS
CONTENTS
118 How to Read a Table
119 PAR Lamps
121 A19 Lamps
121 Aluminum Reflector Lamps
121 Double Envelope Lamps
122 MR8, MR11, MR16 Lamps
126 JC Type Lamps
127 J Type Double Ended Lamps
128 JD Type Single Ended Lamps
130 Bulb, Base and Filament Identification
131 Symbols, Footnotes and Abbreviations

main
TOC

HOW TO READ A HALOGEN LAMP TABLE
PACKAGE QUANTITY

Indicates minimum sell quantity
and smallest shipping carton.

BULB

Designations indicate shape and size.
Illustrations can be found on page 130
and at the top of each page.

Abbreviated product description
can also be used for ordering.
A key to abbreviations can be
found on page 132.

Indicates base type.
Full base descriptions
and illustrations can be
found on page 130.

Product
Number

Base

&

Filament types are
illustrated on
page 130.

PRODUCT CODE

BASE

Bulb

DESIGN
FILAMENT

Footnotes

Product
Code

Description

VOLTS

Indicate the
product’s
design voltage
of operation.

MOL

Indicates
maximum
overall length
in inches.

Pkg.
Qty.

Volts

Lumens

CBCP

Avg.
Life

Design
Filament

MOL

Beam
Spread

10/1000

12

60

2800

3000

C-8

1.18”

-

10/1000

12

120

2800

3000

C-8

1.50”

-

JC Type

5 WATT
T3

G4

107006

3

JC5

Clear

147008

3

JC10/BA15S

Clear

107944

2,3

JC10/BA15S/HX

Clear HaloXen

10/1000

12

120

2850

10000

C-8

1.50”

-

107008

3

JC10

Clear

10/1000

12

120

2800

3000

C-8

1.18”

-

107710

2,3

JC10/HX

Clear HaloXen®

10/1000

12

120

2850

10000

C-8

1.18”

-

90002

3

JC10/X

Clear Xenon

10/500

12

120

2700

20000

C-8

1.18”

-

10 WATT
T3

BA15s

G4

WATTS

Indicates the
power consumed
by the lamp during
operation.

FOOTNOTES &
SYMBOLS

Related footnotes can
be found on page 131.

PRODUCT
NUMBER

Use this number when
placing an order.

®

DESCRIPTION

AVERAGE
LIFE

Bulb finish and other
important information.

Average rated life
expressed in hours.

LUMENS
Represents
the average
light output.

BEAM
SPREAD
CBCP

The luminous
intensity at the center
of the beam of a
reflector lamp.

TOC

Indicates the
beam angle or
beam spread
of a bulb,
measured in
degrees.

HALOGEN LAMPS
PAR30
PAR30L

PAR38

Bulb

Product
Number

Base

,

Footnotes

,

PAR36

PAR20

Product
Code

&

PAR16

Description

Pkg.
Qty.

Volts

Lumens

CBCP

Avg.
Life

Design
Filament

MOL

Beam
Spread

1/12

24

240

480

5000

CC-6

2.75”

32°

PAR Lamps

20 WATT
PAR36

MPTerm.

70304

X $ 1,7

HP36WFL20/24V

Wide Flood

107788

$ 1,2,7

HP36NSP20/HX

Narrow Spot HaloXen

1/12

12

260

1900

5000

C-6

2.75”

12°

107790

$ 1,2,7

HP36VNSP20/HX

Very Narrow Spot
HaloXen®

1/12

12

260

9000

5000

C-6

2.75”

5°

107792

$ 1,2,7

HP36WFL20/HX

Wide Flood HaloXen®

1/12

12

260

530

5000

C-6

2.75”

32°

HP20NFL35

Narrow Flood

15

130

450

700

3000

CC-8

3.07”

30°

®

35 WATT
PAR20

Med.

107610

N $ 1,7,8

PAR36

MPTerm.

107794

$ 1,2,7

HP36NSP35/HX

Narrow Spot HaloXen®

1/12

12

540

3500

5000

C-6

2.75”

12°

107796

$ 1,2,7

HP36VNSP35/HX

Very Narrow Spot
HaloXen®

1/12

12

540

17000

5000

C-6

2.75”

5°

107798

$ 1,2,7

HP36WFL35/HX

Wide Flood HaloXen®

1/12

12

540

1000

5000

C-6

2.75”

32°

70306

$ 1,2,7

HP36WFL35/24V

Wide Flood

1/12

24

500

960

5000

CC-6

2.75”

32°

70343

$  1,2,7

HP20NFL39/HX

Narrow Flood HaloXen®

1/15

120

530

900

2000

CC-8

3.23"

30°

70354

$  1,2,7

HP20NFL39/HX/130

Narrow Flood HaloXen

1/15

130

530

900

2000

CC-8

3.23”

30°

70347

$  1,2,7

HP30FL39/HX

Flood HaloXen

1/15

120

530

1100

2000

CC-8

3.62"

30°

70353

$  1,2,7

HP30FL39/HX/130

Flood HaloXen

1/15

130

530

1100

2000

CC-8

3.62”

30°

70344

$  1,2,7

HP30FL39L/HX

Flood HaloXen

1/15

120

530

1000

2000

CC-8

4.75"

36°

70204

$  1,2,7

HP30WFL39L/HX

Wide Flood HaloXen®

1/15

120

530

650

2000

CC-8

4.75"

50°

70203

$  1,2,7

HP30SP39L/HX

Spot HaloXen®

1/15

120

530

4000

2000

CC-8

4.75"

15°

70356

$  1,2,7

HP30FL39L/HX/130

Flood HaloXen

1/15

130

530

4000

2000

CC-8

4.75”

36°

70340

$  1,2,7

HP38FL39/HX

Flood HaloXen

1/15

120

530

1000

2000

CC-8

5.31”

30°

70404

$  1,2,7

HP38SP39/HX

®

Spot HaloXen

1/15

120

530

5000

2000

CC-8

5.31"

10°

70355

$  1,2,7

HP38FL39/HX/130

Flood HaloXen

1/15

130

530

1100

2000

CC-8

5.31”

30°

107502

N $ 1,7,8

HP16NFL45

Narrow Flood

15

130

450

850

3000

CC-2V

3.07”

30°

107782

1,2,7

HP36NSP50/HX

Narrow Spot HaloXen®

1/12

12

910

5000

5000

C-6

2.75”

12°

107784

1,2,7

HP36VNSP50/HX

Very Narrow Spot
HaloXen®

1/12

12

910

25000

5000

C-6

2.75”

5°

107786

1,2,7

HP36WFL50/HX

Wide Flood HaloXen®

1/12

12

910

1500

5000

C-6

2.75”

32°

 1,2,7

HP38FL50/S/HX

Silver PAR Flood HaloXen® 1/15

120

920

1300

1500

CC-8

5.31”

30°

39 WATT
PAR20

PAR30

Med.

Med.

PAR30L Med.

PAR38

Med.

®

®

®

®

®

®

®

45 WATT
PAR16

Med.

50 WATT
PAR36

PAR38

MPTerm.

Med.

70350

E

53 WATT
Med.

70310

PAR30L Med.

70311

PAR38

70312

PAR30

Med.

E

$  1,2,7

HP30FL53/XIR

Flood XIR®

1/15

120

1050

2500

3500

CC-8

3.62”

30°

E

$  1,2,7

HP30FL53L/XIR

Flood XIR

1/15

120

930

2500

3500

CC-8

4.75”

30°

E

$  1,2,7

HP38FL53/XIR

Flood XIR

1/15

120

960

4100

3500

CC-8

5.31”

25°

®

®

E Means this lamp meets Federal Minimum Efficiency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 119

HALOGEN LAMPS
BR30
BR38
BR40

Bulb

Product
Number

Base

,

Footnotes

,

Product
Code

&

PAR30
PAR30L

PAR16

Description

PAR56
PAR64

PAR38

Pkg.
Qty.

Volts

Lumens

CBCP

Avg.
Life

Design
Filament

MOL

Beam
Spread

PAR Lamps continued

60 WATT
PAR16

Med.

107616

N $1,7,8

HP16NFL60

Narrow Flood

15

130

550

1500

3000

CC-8

3.07”

30°

107850

N $1,7,8

HP16NFL60/120

Narrow Flood

15

120

550

1500

3000

CC-8

3.07”

30°

15

130

550

4000

3000

CC-8

3.07”

10°

107504
PAR30

N $1,7,8

HP16NSP60

Narrow Spot

Med.

70345

E

 $ 1,2,7

HP30FL60/S/HX

Silver PAR Flood HaloXen

1/15

120

1090

2300

1500

CC-8

3.62”

30°

PAR30L Med.

70342

E

 $ 1,2,7

HP30FL60L/S/HX

Silver PAR Flood HaloXen® 1/15

120

1090

1900

1500

CC-8

4.75”

36°

70349

E

 $ 1,2,7

HP30WFL60L/S/HX

Silver PAR Wide
Flood HaloXen®

1/15

120

1090

1200

1500

CC-8

4.75”

50°

70348

E

 $ 1,2,7

HP30SP60L/S/HX

Silver PAR Spot HaloXen®

1/15

120

1090

5800

1500

CC-8

4.75”

15°

70341

E

 $ 1,2,7

HP38FL60/S/HX

Silver PAR Flood HaloXen® 1/15

120

1090

2000

1500

CC-8

5.31”

30°

PAR38

Med.

®

65 WATT
BR30

Med.

75009

 1,7

BR30FL65/H

Flood

24

120

750

-

2500

CC-8

5.37”

-

BR40

Med.

75010

 1,7

BR40FL65/H

Flood

24

120

750

-

2500

CC-8

6.56”

-

70 WATT
PAR38

Med.

E

 $ 1,2,7

HP38FL70/S/HX

Silver PAR Flood HaloXen® 1/15

120

1350

2800

1500

CC-8

5.31”

30°

70352

E

 $ 1,2,7

HP38SP70/S/HX

Silver PAR Spot HaloXen

1/15

120

1350

7200

1500

CC-8

5.31”

10°

70351

E

 $ 1,2,7

HP38FL80/S/HX

Silver PAR Flood HaloXen® 1/15

120

1580

3000

1500

CC-8

5.31”

30°

70346

®

80 WATT
PAR38

Med.

250 WATT
PAR38

Med.

15558

N 1,5,7

Q250PAR/FL

Flood Major

1/6

120

3600

9000

4500

CC-8

5.32”

30°

15526

N 1,5,7

Q250PAR/SP

Spot Major

1/6

120

3600

40000

4500

CC-8

5.32”

10°

65044

1,5,6,7

PAR56MFL500Q

Medium Flood

1/12

120

8000

43000

3000

CC-6

5.00” 30x11

65043

1,5,6,7

PAR56NSP500Q

Narrow Spot

1/12

120

8000

73500

3000

CC-6

5.00”

65045

1,5,6,7

PAR56WFL500Q

Wide Flood

1/12

120

8000

19000

3000

CC-6

5.00” 45x20

500 WATT
PAR56

End
Prg.

15x8

E Means this lamp meets Federal Minimum Efficiency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.

120

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HALOGEN LAMPS
A19

Bulb

Base

AR111

Product
Number

Footnotes

BT15

Product
Code

Description

Pkg.
Qty.

Volts

Lumens

CBCP

Avg.
Life

Design
Filament

MOL

Beam
Spread

A19 Lamps
29 WATT
A19

Med.

76005

E

$

A19CL29/H

Clear

12/120

120

430

-

1000

CC-8

4.25”

-

76001

E

$

A19SW29/H

Soft White

12/120

120

430

-

1000

CC-8

4.25”

-

76006

E

$

A19CL43/H

Clear

12/120

120

750

-

1000

CC-8

4.25”

-

76004

E

$

A19SW43/H

Soft White

12/120

120

750

-

1000

CC-8

4.25”

-

76007

E

$

A19CL53/H

Clear

12/120

120

1050

-

1000

CC-8

4.25”

-

76002

E

$

A19SW53/H

Soft White

12/120

120

1050

-

1000

CC-8

4.25”

-

76000

E

$

A19CL72/H

Clear

12/120

120

1490

-

1000

CC-8

4.25”

-

76003

E

$

A19SW72/H

Soft White

12/120

120

1490

-

1000

CC-8

4.25”

-

43 WATT
A19

Med.

53 WATT
A19

Med.

72 WATT
A19

Med.

Aluminum Reflector
50 WATT
AR111

G53

104150

3

AR111FL50

Flood

1/6

12

-

4100

3000

C-8

2.64”

24°

104154

3

AR111SP50

Spot

1/6

12

-

23000

3000

C-8

2.64”

8°

104158

3

AR111WFL50

Wide Flood

1/6

12

-

1200

3000

C-8

2.64”

45°

75 WATT
AR111

G53

104152

3

AR111FL75

Flood

1/6

12

-

5300

3000

C-8

2.64”

24°

104156

3

AR111SP75

Spot

1/6

12

-

30000

3000

C-8

2.64”

8°

104160

3

AR111WFL75

Wide Flood

1/6

12

-

1700

3000

C-8

2.64”

45°

Double Envelope
60 WATT
BT15

Med.

107052

N, 4

JTT60/SW

Soft White

10/200

120

820

-

2500

CC-8

4.61”

-

107048

N, 4

JTT75/SW

Soft White

10/200

120

1000

-

2500

CC-8

4.61”

-

75 WATT
BT15

Med.

E Means this lamp meets Federal Minimum Efficiency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 121

HALOGEN LAMPS
MR11
GU10

Bulb

Base

Product
Number

&

Footnotes

Product
Code

MR8
GU4

Description

MR11
GU4

MR11
BA15d

MR16
GU5.3

Pkg.
Qty.

Volts

CBCP

Color
Temp

Avg.
Life

Design
Filament

MOL

Beam
Spread

MR8, MR11 & MR16

5 WATT
MR11

GU4

107516

3

MR11FL5/L

Flood w/Lens

10/200

12

80

2950

2000

C-6

1.38”

30°

10 WATT
MR8

GU4

107488

3

MR8W10/L

Wide Flood w/Lens

10/200

12

300

3000

2000

C-8

1.30”

20°

MR11

GU4

107940

3

MR11FL10/L

Flood w/Lens

10/200

12

300

2900

2000

C-6

1.38”

30°

MR16

GU5.3

107114

3

MR11SP10/L

Spot w/Lens

10/200

12

2500

2900

2000

C-6

1.38”

10°

107098

3

MR16FL10

Flood

10/100

12

340

2900

3000

C-6

1.77”

36°

107097

3

MR16FL10/L

Flood w/Lens

10/100

12

200

2900

2000

C-6

1.77”

36°

107094

3

MR16SP10/L

Spot w/Lens

10/100

12

2000

2900

2000

C-6

1.77”

12°

70754

X $ 2,3

MR16SP20/L/16HX

Spot w/Lens HaloXen®

10/100

12

3600

3100

5000

C-8

1.77”

10°

MR16NFL20/L/16HX

Narrow Flood w/Lens
HaloXen®

10/100

12

1100

3100

5000

C-8

1.77”

25°

MR16FL20/L/16HX

Flood w/Lens HaloXen®

10/100

12

650

3100

5000

C-8

1.87”

36°

MR16WFL20/L/16HX

Wide Flood w/Lens
HaloXen®

10/100

12

400

3100

5000

C-8

1.77”

60°

16 WATT
MR16

GU5.3

70753

X $ 2,3

70752

$ 2,3

70755

X $ 2,3

107466

3

MR8N20/L

Narrow Flood w/Lens

10/200

12

1750

3000

2000

C-8

1.30”

10°

108610

3

MR8W20/L

Wide Flood w/Lens

10/200

12

900

3000

2000

C-8

1.30”

20°

20 WATT
MR8

GU4

MR11

BA15d

GU4

MR16

107101

3

MR11FTB/L/TL

107103

3

MR11FTC/L/TL

Narrow Spot w/Lens
Twist Lock
Medium Flood w/Lens
Twist Lock

107105

3

MR11FTD/L/TL

Flood w/Lens Twist Lock

10/200

12

700

2900

3000

C-6

1.77”

30°

107100

3

MR11FTB/L

Narrow Spot w/Lens

10/200

12

5500

2900

3000

C-6

1.38”

10°

MR11FTB/L/HX

Narrow Flood w/Lens
HaloXen®

10/200

12

4100

3100

10000

C-8

1.38”

10°

MR11FTB/L/24V

Narrow Spot w/Lens

10/200

24

2800

2900

3000

CC-6

1.38”

10°

MR11FTC/L

Medium Flood w/Lens

10/200

12

1750

2900

3000

C-6

1.38”

20°

MR11FTC/L/HX

Medium Flood w/Lens
HaloXen®

10/200

12

1750

3100

10000

C-8

1.38”

20°

MR11FTC/L/24V

Medium Flood w/Lens

10/200

24

1000

2900

3000

CC-6

1.38”

20°

MR11FTD/L

Flood w/Lens

10/200

12

700

2900

3000

C-6

1.38”

30°

MR11FTD/L/HX

Flood w/Lens HaloXen

10/200

12

700

3100

10000

C-8

1.38”

30°

120

220

3000

2000

CC-2V

1.38”

30°

107922

X 2,3

107472

X3

107102

3

10/200

12

5500

2900

3000

C-6

1.77”

10°

10/200

12

1750

2900

3000

C-6

1.77”

20°

107924

X 2,3

107474

X,3

107104

3

107926

2,3

GU10

107544

3

MR11FL20/L/GU10

Flood w/Lens

10/200

GU5.3

107480

3

MR16BAB

Flood

10/100

12

460

2900

3000

C-8

1.77”

38°

107120

3

MR16BAB/SC

Flood SureColor®

10/100

12

700

2950

5000

C-8

1.77”

38°

107494

3

MR16BAB/L

Flood w/Lens

10/100

12

450

2900

3000

C-8

1.77”

38°

107121

3

MR16BAB/L/SC

Flood w/Lens SureColor

10/100

12

700

2950

5000

C-8

1.77”

38°

107526

2,3

MR16BAB/L/HX

Flood w/Lens HaloXen

10/100

12

700

3100

10000

C-8

1.87”

36°

®

®

®

E Means this lamp meets Federal Minimum Efficiency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.

122

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HALOGEN LAMPS
MR11
GU4

Bulb

Base

MR16
GU5.3

Product
Number

&

Footnotes

MR16
GU10

Product
Code

Description

Pkg.
Qty.

Volts

CBCP

Color
Temp

Avg.
Life

Design
Filament

MOL

Beam
Spread

MR8, MR11 & MR16 continued

20 WATT continued
MR16

GU5.3

GU10

70700

3

MR16BAB/L/AL

Flood w/Lens

10/100

12

650

2950

5000

C-8

1.77”

36°

70710

3

MR16BAB/L/AL/24V

Flood w/Lens

10/100

24

650

2950

5000

CC-8

1.77”

38°

10/100

12

450

2950

5000

C-8

1.77”

38°

107300

X3

MR16BAB/FR/SC

Frosted Flood w/Lens
SureColor®

107350

3

MR16BAB/BLK/L

Flood Black Back w/Lens

10/100

12

900

2950

5000

C-8

1.87”

38°

107115

3

MR16BAB/BLU

Blue Flood

10/100

12

850

-

3000

C-6

1.77”

38°

107116

3

MR16BAB/GRN

Green Flood

10/100

12

850

-

3000

C-6

1.77”

38°

107118

3

MR16BAB/RED

Red Flood

10/100

12

850

-

3000

C-6

1.77”

38°

10/100

12

1500

2950

5000

C-8

1.77”

20°

10/100

12

3350

2900

3000

C-8

1.77”

12°

10/100

12

4000

2950

5000

C-8

1.77”

10°

10/100

12

3280

2900

3000

C-8

1.77”

12°

10/100

12

4000

2950

5000

C-8

1.87”

10°

10/100

12

4100

3100

10000

C-8

1.77”

10°

10/100

12

450

2950

5000

C-8

1.77”

60°

10/100

12

450

2950

5000

C-8

1.77”

60°

10/100

12

400

3100

10000

C-8

1.77”

60°

107440

3

MR16BBF/L/SC

Medium Flood w/Lens
SureColor®

107482

3

MR16ESX

Narrow Spot

107122

3

MR16ESX/SC

Narrow Spot SureColor

107496

3

MR16ESX/L

Narrow Spot w/Lens

107123

3

MR16ESX/L/SC

107932

X 2,3

MR16ESX/L/HX

Narrow Spot w/Lens
SureColor®
Narrow Spot w/Lens
HaloXen®

107090

3

MR16WFL20/SC

Wide Flood SureColor®

®

107400

3

MR16WFL20/L/SC

107942

2,3

MR16WFL20/L/HX

Wide Flood w/Lens
SureColor®
Wide Flood w/Lens
HaloXen®

70702

3

MR16WFL20/L/AL

Wide Flood w/Lens

10/100

12

400

2950

5000

C-8

1.77”

60°

70716

X3

MR16WFL20/L/AL/24V Wide Flood w/Lens

10/100

24

400

2950

5000

CC-8

1.77”

60°

107152

3

MR16FL20/L/GU10

Flood w/Lens

10/200

120

170

2800

2000

CC-2V

2.16”

30°

70758

X $ 2,3

MR16SP35/L/26HX

Spot w/Lens HaloXen®

10/100

12

6500

3100

5000

C-8

1.77”

10°

70757

X $ 2,3

MR16NFL35/L/26HX

Narrow Flood w/Lens
HaloXen®

10/100

12

3150

3100

5000

C-8

1.77”

25°

70756

$ 2,3

MR16FL35/L/26HX

Flood w/Lens HaloXen®

10/100

12

1250

3100

5000

C-8

1.77”

36°

MR16WFL35/L/26HX

Wide Flood w/Lens
HaloXen®

10/100

12

800

3100

5000

C-8

1.77”

60°

10/200

12

4600

2900

3000

C-6

1.77”

10°

10/200

12

2400

2900

3000

C-6

1.65”

20°

26 WATT
MR16

GU5.3

70759

X $ 2,3

107454

X3

MR11FTE/L/TL

107456

3

MR11FTF/L/TL

Narrow Spot w/Lens
Twist Lock
Medium Flood w/Lens
Twist Lock

107106

3

MR11FTE/L

Narrow Spot w/Lens

10/200

12

4600

2900

3000

C-6

1.38”

10°

107108

3

MR11FTF/L

Medium Flood w/Lens

10/200

12

2400

2900

3000

C-6

1.38”

20°

MR11FTF/L/HX

Medium Flood w/Lens
HaloXen®

10/200

12

3000

3100

10000

C-8

1.38”

20°

35 WATT
MR11

BA15d

GU4

107928

X 2,3

E Means this lamp meets Federal Minimum Efficiency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 123

HALOGEN LAMPS
MR11
GU4

Bulb

Base

Product
Number

&

Footnotes

Product
Code

Description

MR16
GU5.3

MR11
GU10

Pkg.
Qty.

Volts

CBCP

Color
Temp

Avg.
Life

Design
Filament

MOL

Beam
Spread

MR8, MR11 & MR16 continued

35 WATT continued
MR11

MR16

GU4

107110

3

MR11FTH/L

Flood w/Lens

10/200

12

1500

2900

3000

C-6

1.38”

30°

GU10

107546

3

MR11FL35/L/GU10

Flood w/Lens

10/100

120

560

2850

2000

CC-2V

1.38”

30°

10/100

12

3000

3000

5000

C-8

1.77”

20°

10/100

12

3500

3100

10000

C-8

1.87”

20°

10/100

12

8000

3000

5000

C-8

1.77”

10°

10/100

12

8000

3000

5000

C-8

1.77”

10°

10/100

24

5000

3000

4000

CC-6

1.77”

12°

10/100

12

950

3000

3000

C-8

1.77”

36°

10/100

12

1500

3000

5000

C-8

1.77”

38°

10/100

12

880

3000

3000

C-8

1.77”

36°

10/100

12

1500

3000

5000

C-8

1.77”

38°

10/100

12

1250

3100

10000

C-8

1.77”

38°

GU5.3

GU10

107141

3

MR16FRA/L/SC

107938

2,3

MR16FRA/L/HX

Narrow Flood w/Lens
SureColor®
Narrow Flood w/Lens
HaloXen®

107136

3

MR16FRB/SC

Spot SureColor®

MR16FRB/L/SC

Spot w/Lens SureColor

MR16FRB/24V

Spot

3

MR16FMW

Flood

107138

3

MR16FMW/SC

Flood SureColor

107508

3

MR16FMW/L

Flood w/Lens

107139

3

MR16FMW/L/SC

Flood w/Lens SureColor

107518

2,3

MR16FMW/L/HX

Flood w/Lens HaloXen

70704

3

MR16FMW/L/AL

Flood w/Lens

10/100

12

1300

3000

5000

C-8

1.77”

36°

107420

3

107446

X3

107492

GU5.3

®

®

®

70714

3

MR16FMW/L/AL/24V

Flood w/Lens

10/100

24

1300

3000

5000

CC-8

1.77”

38°

107362

3

MR16FMW/BLK/L

Flood Black Back w/Lens

10/100

12

1700

3000

5000

C-6

1.77”

36°

107092

3

MR16WFL35/SC

Wide Flood SureColor

10/100

12

800

3000

5000

C-8

1.77”

60°

10/100

12

800

3000

5000

C-8

1.77”

60°

10/100

12

750

3100

10000

C-8

1.77”

60°

®

107430

3

MR16WFL35/L/SC

70720

2,3

MR16WFL35/L/HX

Wide Flood w/Lens
SureColor®
Wide Flood w/Lens
HaloXen®

70706

3

MR16WFL35/L/AL

Wide Flood w/Lens

10/100

12

700

3000

5000

C-8

1.77”

60°

70718

3

MR16WFL35/L/AL/24V Wide Flood w/Lens

10/100

24

700

3000

5000

CC-8

1.77”

60°

107154

3

MR16FL35/L/GU10

Flood w/Lens

10/100

120

900

2800

2000

CC-2V

2.16”

30°

70737

$ 2,3

MR16NFL50/L/37HX

Narrow Flood w/Lens
HaloXen®

10/100

12

4400

3100

5000

C-8

1.87”

25°

70736

$ 2,3

MR16FL50/L/37HX

Flood w/Lens HaloXen®

10/100

12

2200

3100

5000

C-8

1.87”

36°

107484

3

MR16EXN

Flood

10/100

12

1350

2900

3000

C-8

1.77”

36°

37 WATT
MR16

®

50 WATT
MR16

124

GU5.3

TOC

107124

3

MR16EXN/SC

Flood SureColor

10/100

12

2000

3050

5000

C-8

1.77”

38°

107498

3

MR16EXN/L

Flood w/Lens

10/100

12

1350

2900

3000

C-8

1.77”

36°

107125

3

MR16EXN/L/SC

Flood w/Lens SureColor®

10/100

12

2000

3050

5000

C-8

1.77”

38°

107514

2,3

MR16EXN/L/HX

Flood w/Lens HaloXen

10/100

12

1700

3150

10000

C-8

1.87”

38°

70708

3

MR16EXN/L/AL

Flood w/Lens

10/100

12

1900

2900

5000

C-8

1.77”

36°

MR16EXN/FR/SC

Flood Frost w/Lens
SureColor®

10/100

12

1050

3050

5000

C-8

1.77”

38°

®

®

107304

X,3

107452

3

MR16EXN/24V

Flood

10/100

24

1600

2900

4000

CC-6

1.77”

36°

107356

3

MR16EXN/BLK/L

Flood Black Back w/Lens

10/100

12

2200

3050

5000

C-8

1.77”

36°

107358

3

MR16EXN/SIL/L

Flood Silver Back w/Lens

10/100

12

2200

3050

5000

C-8

1.77”

36°

E Means this lamp meets Federal Minimum Efficiency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HALOGEN LAMPS
MR16
GU10

MR16
GU5.3/G8

Bulb

Product
Number

Base

&

Footnotes

Product
Code

JDR
Int.

JDR
Med.

Description

Pkg.
Qty.

Volts

CBCP

Color
Temp

Avg.
Life

Design
Filament

MOL

Beam
Spread

MR8, MR11 & MR16 continued

50 WATT continued
MR16

GU5.3

107172

3

MR16EXN/BLU

Blue Flood

10/100

12

1350

-

3000

C-8

1.77”

36°

107174

3

MR16EXN/GRN

Green Flood

10/100

12

1350

-

3000

C-8

1.77”

36°

107170

3

MR16EXN/RED

Red Flood

10/100

12

1350

-

3000

C-8

1.77”

36°

107176

3

MR16EXN/YEL

Yellow Flood

10/100

12

1350

-

3000

C-8

1.77”

36°

107486

3

MR16EXT

Spot

10/100

12

11000

2900

3000

C-8

1.77”

12°

107126

3

MR16EXT/SC

Spot SureColor®

10/100

12

10000

3050

5000

C-8

1.77”

10°

107500

3

MR16EXT/L

Spot w/Lens

10/100

12

10700

2900

3000

C-8

1.77”

12°

107127

3

MR16EXT/L/SC

Spot w/Lens SureColor

10/100

12

10000

3050

5000

C-8

1.77”

10°

107934

2,3

MR16EXT/L/HX

Spot w/Lens HaloXen

10/100

12

10000

3150

10000

C-8

1.77”

12°

107490

3

MR16EXZ

Narrow Flood

10/100

12

3000

2900

3000

C-8

1.77”

24°

107128

3

MR16EXZ/SC

Narrow Flood SureColor

10/100

12

4000

3050

5000

C-8

1.77”

20°

107464

X,3

MR16EXZ/U

107506

3

MR16EXZ/L

107129

3

107936

2,3

107146

3

107462

X,3

MR16EXZ/L/SC
MR16EXZ/L/HX

®

®

®

Narrow Flood

10/100

12

3500

3150

12000

C-8

1.77”

20°

Narrow Flood w/Lens

10/100

12

2940

2900

3000

C-8

1.77”

24°

10/100

12

4000

3050

5000

C-8

1.77”

20°

10/100

12

4400

3150

10000

C-8

1.87”

24°

Narrow Flood w/Lens
SureColor®
Narrow Flood w/Lens
HaloXen®

MR16FNV/SC

Wide Flood SureColor®

10/100

12

1050

3050

5000

C-8

1.77”

60°

MR16FNV/U

Wide Flood

10/100

12

750

3050

12000

C-8

1.77”

60°

10/100

12

1050

3050

5000

C-8

1.77”

60°

10/100

12

1000

3150

10000

C-8

1.87”

60°

Wide Flood w/Lens
SureColor®
Wide Flood w/Lens
HaloXen®

107410

3

MR16FNV/L/SC

107524

2,3

MR16FNV/L/HX

G8

108510

3

MR16EXN/G8

Flood

10/100

120

1350

2900

2000

CC-2V

1.77”

36°

GU10

107180

3

MR16FL50/L/GU10

Flood w/Lens

10/100

120

1500

2900

2000

CC-2V

2.16”

30°

70760

$ 2,3

MR16FL75/L/57HX

Flood w/Lens HaloXen®

10/100

12

2400

3100

5000

C-8

1.87”

36°

107130

3

MR16EYC/SC

Flood SureColor®

10/100

12

2750

3100

5000

C-8

1.77”

38°

107132

3

MR16EYF/SC

Spot SureColor

10/100

12

13000

3100

5000

C-8

1.77”

10°

10/100

12

6000

3100

5000

C-8

1.77”

20°

57 WATT
MR16

GU5.3

75 WATT
MR16

JDR

GU5.3

®

107134

3

MR16EYJ/SC

Narrow Flood
SureColor®

107312

3

MR16WFL75/SC

Wide Flood SureColor

10/100

12

1400

3100

5000

C-8

1.77”

60°

107314

3

MR16WFL75/L/SC

Wide Flood w/Lens
SureColor®

10/100

12

1400

3100

5000

C-8

1.77”

60°

Int.

107056

N,3

JDR75INT/L

Wide Flood w/Lens

10/200

130

1600

2950

2000

CC-2V

3.15”

30°

Med.

107054

N,3

JDR75/L

Wide Flood w/Lens

10/200

130

1600

2950

2000

CC-2V

3.15”

30°

®

E Means this lamp meets Federal Minimum Efficiency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 125

HALOGEN LAMPS
JC
G9

Bulb

Base

Product
Number

&

Footnotes

Product
Code

Description

JC
G4
GY6.35
G8

JC/
JCD
G6.35

JC
BA15s

JC
BA15d

Pkg.
Qty.

Volts

Lumens

Color
Temp

Avg.
Life

Design
Beam
MOL
Filament
Spread

10/1000

12

60

2800

3000

C-8

1.18”

-

10/1000

12

120

2800

3000

C-8

1.50”

-

120

2850

10000

C-8

1.50”

-

JC Type

5 WATT
T3

G4

107006

3

JC5

Clear

147008

3

JC10/BA15S

Clear

107944

2,3

10 WATT
T3

BA15s

G4

JC10/BA15S/HX

Clear HaloXen

10/1000

12

JC10

Clear

10/1000

12

120

2800

3000

C-8

1.18”

-

JC10/HX

Clear HaloXen®

10/1000

12

120

2850

10000

C-8

1.18”

-

10/500

12

120

2700

20000

C-8

1.18”

-

10/1000

12

300

2800

3000

C-8

1.50”

-

®

107008

3

107710

2,3

90002

3

JC10/X

Clear Xenon

147010

3

JC20/BA15S

Clear

107718

2,3

JC20/BA15S/HX

Clear HaloXen

10/1000

12

350

2900

10000

C-8

1.50”

-

107010

3

JC20

Clear

107712

2,3

JC20/HX

70922

2,3

90003

3

107009

3

GY6.35 107036
G8

20 WATT
T3

BA15s

G4

T4

G6.35

®

10/1000

12

300

2800

3000

C-8

1.18”

-

Clear HaloXen

®

10/1000

12

350

2900

10000

C-8

1.18”

-

JC20/24V/HX

Clear HaloXen

®

10/1000

24

350

4100

5000

CC-6

1.25”

-

JC20/X

Clear Xenon

10/500

12

250

2700

10000

C-8

1.18”

-

JC20/6.35

Clear

10/1000

12

300

2800

3000

C-8

1.65”

-

3

JCD20

Clear

10/500

130

180

2750

2000

CC-2

1.69”

-

107076

3

JCD20/G8

Clear

10/500

130

180

2750

2000

CC-2

1.69”

-

71001

3

JCD25/G9

Clear

10/500

130

280

2650

2000

CC-2V

1.69”

-

107902

3

JCD25FR/G9

Frost

10/500

130

280

2650

2000

CC-2V

1.69”

-

JC35/BA15D

Clear

10/1000

12

600

2850

3000

C-8

1.65”

-

JC35/BA15D/HX

Clear HaloXen®

10/1000

12

600

2900

10000

C-8

1.50”

-

10/1000

12

600

2850

3000

C-8

1.58”

-

10/1000

12

600

2850

3000

C-8

1.58”

-

10/1000

12

600

2900

10000

C-8

1.60”

-

25 WATT
T4

G9

35 WATT
T4

BA15d

147012

3

107720

X3

G4

107000

3

JC35/G4

Clear

G6.35

107012

3

JC35

Clear

107714

2,3

JC35/HX

Clear HaloXen

GY6.35 107011

3

JCD35

Clear

10/500

130

350

2800

2000

CC-2V

1.81”

-

G8

107072

3

JCD35/G8

Clear

10/500

130

350

2800

2000

CC-2V

1.69”

-

107906

3

JCD40/G9

Clear

10/500

130

480

2750

2000

CC-2V

1.69”

-

107908

3

JCD40/FR/G9

Frost

10/500

130

450

2750

2000

CC-2V

1.69”

-

107310

3

JCD40/FR/G9/120

Frost

10/1000 120

450

2800

2000

CC-2V

1.69”

-

®

40 WATT
T4

G9

E Means this lamp meets Federal Minimum Efficiency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.

126

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HALOGEN LAMPS
JC
G4
G8

Bulb

JC/
JCD
G6.35

Product
Number

Base

&

JC
G9

Footnotes

T3
JD
R7s

JC
GY6.35

Product
Code

Pkg.
Qty.

Description

Volts

Lumens

Color
Temp

Avg.
Life

Design
Beam
MOL
Filament
Spread

JC Type continued

50 WATT
T4

G6.35

JC50

Clear

JC50/HX

3

107074

107014

3

10/1000

12

900

2950

3000

C-8

1.65”

-

107716

2,3

Clear HaloXen

10/1000

12

900

3000

10000

C-8

1.60”

-

GY6.35 107015

JCD50

Clear

10/500

130

600

2900

2000

CC-2

1.69”

-

G8

3

JCD50/G8

Clear

10/500

130

600

2900

2000

CC-2

1.69”

-

71002

3

JCD60/G9

Clear

10/500

130

780

2950

2000

CC-2V

1.69”

-

107904

3

JCD60FR/G9

Frost

10/500

130

750

2950

2000

CC-2V

1.69”

-

GY6.35 107002

3

JC75

Clear

10/1000

12

1350

3000

3000

C-8

1.69”

-

107001

3

JCD75

Clear

10/500

130

980

2950

2000

CC-2V

1.69”

-

GY6.35 107004

3

JC100

Clear

10/1000

12

2100

3100

3000

C-8

1.69”

-

107003

3

JCD100

Clear

10/500

130

1400

3050

2000

CC-2V

1.69”

-

3

JCD100/G8

Clear

10/500

130

1400

3050

2000

CC-2V

1.69”

-

®

60 WATT
T4

G9

75 WATT
T4

100 WATT
T4

G8
Bulb

Base

107070
Product
Number

Footnotes

Product
Code

ANSI

Description

Pkg.
Qty.

Volts

Lumens

Color
Temp

Avg.
Life

Design
Filament

MOL

Beam
Spread

J Type Double Ended
75 WATT
T3

R7s

107210

3,8,9

Q75T3C/S

-

Clear 78mm

10/500

130

1250

2850

2000

C-8

3.07”

-

107182

3,8,9

Q100T3C

-

Clear 118mm

10/500

130

1400

2950

2000

C-8

4.68”

-

107184

3,8,9

Q100T3C/S

-

Clear 78mm

10/500

130

1400

2950

2000

C-8

3.11”

-

100 WATT
T3

R7s

150 WATT
T3

R7s

107186

3,8,9

Q150T3C

-

Clear 118mm

10/500

130

2250

2950

2000

C-8

4.68”

-

107188

3,8,9

Q150T3C/S

-

Clear 78mm

10/500

130

2400

2950

2000

C-8

3.07”

-

107214

3,8,9

Q150T3C/12V

-

Clear 83mm Pool

10/500

12

2500

2950

2000

C-8

3.27”

-

107190

3,8,9

Q200T3C

-

Clear 118mm

10/500

130

3200

2950

2000

C-8

4.68”

-

107192

3,8,9

Q200T3C/S

-

Clear 78mm

10/500

130

3200

2950

2000

C-8

3.11”

-

107208

3,8,9

Q250T3C/S

-

Clear 78mm

10/500

130

4000

2950

2000

C-8

3.11”

-

107216

3,8,9

Q250T3C/83MM

-

Clear 83mm Pool

10/500

130

4000

2950

2000

C-8

3.27”

-

107194

3,8,9

Q300T3C

-

Clear 118mm

10/500

130

5000

2950

2000

C-8

4.68”

-

127194

3,8,9

Q300T3C/120

EHM

Clear 118mm

10/500

120

5000

2950

2000

C-8

4.68”

-

200 WATT
T3

R7s

250 WATT
T3

R7s

300 WATT
T3

R7s

E Means this lamp meets Federal Minimum Efficiency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 127

HALOGEN LAMPS
T4
JD
E11

Bulb

Product
Number

Base

Footnotes

Product
Code

ANSI

Description

T4
JD
BA15d

T3
R7s

Pkg.
Qty.

Volts

Lumens

Color
Temp

Avg.
Life

Design
MOL
Filament

Beam
Spread

J Type Double Ended continued
500 WATT
T3

R7s

107196

3,8,9

Q500T3C

DVS

Clear 118mm

10/500

130

9500

3000

2000

C-8

4.65”

-

127196

3,8,9

Q500T3C/120

FCL

Clear 118mm

10/500

120

9500

3000

2000

C-8

4.65”

-

107198

3,8,9

Q1000T3C

-

Clear 254mm

10/500

240

22000

3050

2000

C-8

10.00”

-

107200

3,8,9

Q1500T3C

-

Clear 254mm

10/500

240

33000

3050

2000

C-8

10.00”

-

107202

3,8,9

Q1500T3C/277

-

Clear 254mm

10/500

277

33000

3050

2000

C-8

10.00”

-

1000 WATT
T3

R7s

1500 WATT
T3

R7s

JD Type Single Ended
35 WATT
T4

BA15d 107035

3

Q35CL/DC

-

Clear

10/400

130

380

2700

2000

CC-2V

1.97”

-

E11

107034

3

Q35CL/MC

-

Clear

10/400

130

380

2700

2000

CC-2V

1.97”

-

BA15d 107018

3

Q50CL/DC

-

Clear

10/400

130

750

2800

2000

CC-2V

1.97”

-

E11

107019

3

Q50CL/MC

-

Clear

10/400

130

750

2800

2000

CC-2V 1.97”

-

BA15d 107021

3

Q75CL/DC

-

Clear

10/400

130

1250

2850

2000

CC-8

2.40”

-

E11

107020

3

Q75CL/MC

-

Clear

10/400

130

1250

2850

2000

CC-8

2.68”

-

127020

3

Q75CL/MC/120

-

Clear

10/400

120

1250

2850

2000

CC-8

2.68”

-

BA15d 107025

3

Q100CL/DC

127025

3

Q100CL/DC/120

107024

3

Q100CL/MC

127024

3

Q100CL/MC/120

BA15d 107029

3

Q150CL/DC

71102

3

Q150CL/DC/120

107027

X3

50 WATT
T4

75 WATT
T4

100 WATT
T4

E11

-

Clear

10/400

130

1700

2950

2000

CC-8

2.40”

-

ESR

Clear

10/400

120

1700

2950

2000

CC-8

2.40”

-

-

Clear

10/400

130

1700

2950

2000

CC-8

2.68”

-

ESN

Clear

10/400

120

1700

2950

2000

CC-8

2.68”

-

-

Clear

10/400

130

2400

2950

2000

CC-8

2.40”

-

ETC

Clear

10/200

120

2400

2950

2000

CC-8

2.40”

-

Q150DC

-

Frost

10/400

130

2280

2950

2000

CC-8

2.40”

-

150 WATT
T4

E11

107028

3

Q150CL/MC

-

Clear

10/400

130

2400

2950

2000

CC-8

2.72”

-

127028

X

Q150CL/MC/120

-

Clear

10/400

120

2400

2950

2000

CC-8

2.72”

-

107026

3

Q150MC

-

Frost

10/400

130

2280

2950

2000

CC-8

2.72”

-

71100

3

Q150MC/120

ETH

Frost

10/200

120

2280

2950

2000

CC-8

2.72”

-

E Means this lamp meets Federal Minimum Efficiency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.

128

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HALOGEN LAMPS
T4
JD
E11

Bulb

Base

T4
JD
BA15d

Product
Number

Footnotes

Product
Code

ANSI

Description

Pkg.
Qty.

Volts

Lumens

Color
Temp

Avg.
Life

Design
MOL
Filament

Beam
Spread

JD Type Single Ended continued
250 WATT
T4

BA15d 107033

3

Q250CL/DC

127033

3

71103

-

Clear

10/400

130

4500

2950

2000

CC-8

3.12”

-

Q250CL/DC/120

ESS

Clear

10/400

120

4500

2950

2000

CC-8

3.12”

-

X3

Q250DC/120

ETB

Frost

10/200

120

4200

2950

2000

CC-8

2.76”

-

107032

3

Q250CL/MC

127032

3

Q250CL/MC/120

107030

3

107037

BA15d 107041

-

Clear

10/400

130

4500

2950

2000

CC-8

3.15”

-

EHT

Clear

10/400

120

4500

2950

2000

CC-8

3.15”

-

Q250MC

-

Frost

10/400

130

4200

2950

2000

CC-8

3.15”

-

3

Q400CL/MC

-

Clear

10/400

130

7400

2950

2000

CC-8

3.27”

-

X3

Q500CL/DC

-

Clear

10/400

130

8500

3000

2000

CC-8

3.98”

-

107040

3

Q500CL/MC

EYW

Clear

10/400

130

8500

3000

2000

CC-8

3.75”

-

127040

3

Q500CL/MC/120

EVR

Clear

10/400

120

8500

3000

2000

CC-8

3.75”

-

107038

3

Q500MC

EYV

Frost

10/400

130

8075

3000

2000

CC-8

3.75”

-

400 WATT
T4

E11

500 WATT
T4

E11

E Means this lamp meets Federal Minimum Efficiency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 129

HALOGEN LAMPS
Bulb, Base and Filament Identification Guide
Bulb Shapes

A19

AR111

BR

JDR
Int.

PAR16

JDR
Med.

PAR20

DC
Bayonet
BA15d

GU10

G53

Intermediate
E17

J Type
Tubular

MR

PAR30
PAR30L

Base Types

Screw
Terminals
Up-term

BT15

JC

MR-DC

PAR36

G6.35 or
GY6.35

Medium
E26/27

G8

Mini-Can
E-11

JD

T10

MR-GU10

PAR38

G9

PAR46/56/64

G4
GU4.

Mogul
End Prong
GX16d

Recessed
Single Contact
R7S

GU5.3

SC
Bayonet
BA15s

Filament Types

CC-2

CC-6

CC-8

CC indicates coiled-coil filament.
130

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HALOGEN LAMPS
Symbols, Footnotes and Abbreviations
SYMBOLS
 New product introduced within the past year.
N Nickel-plated brass base.
$ Energy saving product.
E

This lamp meets Federal Minimum Efficiency standards.

X Product will be discontinued when inventory is depleted.

FOOTNOTES
Halogen PAR Caution: Before using bulb, see operating instructions on package. Adhering to these operating
instructions will greatly reduce the risk of personal injury or fire. The halogen capsule contained inside this glass
bulb operates under pressure, at high temperatures and could unexpectedly shatter. Should the outer bulb break,
particles of extremely hot glass could be discharged into the fixture and/or surrounding area, creating a risk of
1 personal injury or fire. Operating Instructions: Turn power off and let lamp cool before replacing or inspecting
to avoid electrical shock or burn. For indoor and outdoor use. A weather-protected fixture is recommended for
wet locations. Suitable for use in open fixtures. Do not exceed the fixture maximum wattage rating. Do not use
if outer glass is scratched or broken. Lamp may continue to operate if outer glass breaks, however immediately
discontinue use. Do not use in close proximity to combustible materials.
HaloXen® lamps operate under high temperatures. To avoid personal injury, turn power off and allow bulb to
2 cool before attempting to handle. Do not use if the glass is scratched or broken. Do not use near flammable or
combustible materials.
Do not touch capsule with bare hands. Oil from the skin may reduce performance unless wiped clean with alcohol
and a soft cloth. CAUTION: THIS LAMP OPERATES UNDER PRESSURE AND COULD SHATTER. To avoid injury
and to avoid exposure to ultraviolet radiation, this lamp should be used in a fixture with a protective shield or
3
tempered glass. Provide adequate ventilation to avoid overheating and use in only fixtures rated for wattage stated
on the package. To avoid risks of burns or other injury, turn power off and allow lamp to cool before replacing.
Socket condition may affect lamp life. Inspect and replace socket if deterioration occurs.
4 Socket condition may affect lamp life. Inspect and replace socket if deterioration occurs.
5 This lamp should be shielded from moisture to prevent breakage.
6 Use only with heat-resistant connector and with lamp supported by bulb rim.
7 Use only in heat-resistant lamp holders and fixtures rated for reflector or PAR lamps.
8

Use outdoors only in enclosed fixtures or where lamp is protected from exposure to water.
Use only in fixtures rated for this product.

9 Operate in a horizontal position only.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 131

HALOGEN LAMPS
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
/12V Suffix used to indicate 12 Volt lamps.
/24V Suffix used to indicate 24 Volt lamps.
/83mm Suffix used to indicate lamps with MOL of 83mm.
/120 Suffix used to indicate 120 Volt lamps.
/130 Suffix used to indicate 130 Volt lamps.
/277V Suffix used to indicate 277 Volt lamps.
/AL Suffix used to indicate lamps with an Aluminum Back reflector.
/BA9s Suffix used to indicate lamps with a BA9s base.
/BA15d Suffix used to indicate lamps with a BA15d base.
/BA15s Suffix used to indicate lamps with a BA15s base.
/BLK Suffix used to indicate lamps with a Black Back, coated reflector.
/BLU Suffix used to indicate lamps with a Blue lens.
CL Code abbreviation for lamps with a Clear finish.
/CS Suffix used to indicate CoverShield® Safety Coated lamps.
/DC Suffix used to indicate lamps with a DC (BA15d) base.
FL Code abbreviation for Flood lamps.
/FR Suffix used to indicate lamps with a Frost Finish.
/G4 Suffix used to indicate lamps with a G4 base.
/G8 Suffix used to indicate lamps with a G8 base.
/G9 Suffix used to indicate lamps with a G9 base.
/GU10 Suffix used to indicate lamps with a GU10 base.
/GRN Suffix used to indicate lamps with a Green lens.
/H Suffix used to indicate Halogen lamps.
HP Code abbreviation for Halogen PAR lamps.
/HX Suffix used to indicate HaloXen® lamps.

132

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

HALOGEN LAMPS
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
INT Code abbreviation for Intermediate (E17) base.
L Code abbreviation for PAR30 lamps with a long neck.
/L Suffix used to indicate lamps with a lens.
LM Code abbreviation for lumens.
/MC Suffix used to indicate lamps Mini-Candelabra (E11) base.
NFL Code abbreviation for Narrow Flood lamps.
/M Suffix used to indicate Major brand lamps (GE, Philips, Osram/Sylvania).
MED Code abbreviation for lamps with a Medium (E26/27) base.
NSP Code abbreviation for Narrow Spot lamps.
Q Code abbreviation to indicate Quartz Halogen.
/RED Suffix used to indicate lamps with a Red lens.
/S Suffix used to indicate Silver PAR HaloXen® lamps.
/SC Suffix used to indicate Prism® SureColor® lamps.
/SIL Suffix used to indicate lamps with a Silver Back, coated reflector.
SP Code abbreviation for Spot lamps.
/SW Suffix used to indicate lamps with a Soft White finish.
/TL Suffix used to indicate lamps with a Twist Lock base (BA15d).
/U Suffix used to indicate Prism® Ultra Life® 12,000 hour lamps.
VNSP Code abbreviation fro Very Narrow Spot lamps.
W Code abbreviation for Wide Flood lamps.
WFL Code abbreviation for Wide Flood lamps.
/X Suffix used to indicate Xenon lamps.
/YEL Suffix used to indicate lamps with a Yellow finish.
/XIR Suffix used to indicate Halogen Infrared lamps.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 133

®

INCANDESCENT LAMPS
CONTENTS
136 How to Read a Table
137 General Service Lamps
147 Decorative Lamps
150 Bulb, Base and Filament Identification
151 Symbols, Footnotes and Abbreviations

main
TOC

HOW TO READ AN INCANDESCENT LAMP TABLE
PACKAGE QUANTITY

Indicates minimum sell quantity
and smallest shipping carton.

BULB

Designations indicate shape and
size. Illustrations can be found on
page 150 and at the top of each
page.

BASE

Indicates base type.
Full base descriptions
and illustrations can be
found on page 150.

Bulb

Base

Product
Number

Footnotes

DESIGN
FILAMENT

Filament types are
illustrated on page
150.

PRODUCT CODE

Abbreviated product description
can also be used for ordering.
A key to abbreviations can be
found on page 152.

Product Code

Description

S11CL7.5

Clear

VOLTS

Indicate the
product’s
design voltage
of operation.

MOL

Indicates
maximum
overall length
in inches.

Pkg.
Qty.

Volts

Lumens

Avg.
Life

Design
Filament

MOL

25/500

130

45

1500

C-7A

2.25”

Beam
Spread

7.5 WATT
S11

Med.

7017
7024

S11GRN7.5C

Ceramic Green

25/500

130

-

1500

C-7A

2.25”

-

7026

S11ORG7.5C

Ceramic Orange

25/500

130

-

1500

C-7A

2.25”

-

7019

S11RED7.5C

Ceramic Red

25/500

130

-

1500

C-7A

2.25”

-

7020

S11WH7.5C

Ceramic White

25/500

130

-

1500

C-7A

2.25”

-

FOOTNOTES &
SYMBOLS

Related footnotes can
be found on page 151.

WATTS

Indicates the
power consumed
by the lamp during
operation.

-

PRODUCT
NUMBER

Use this number
when placing an
order.

DESCRIPTION

AVERAGE
LIFE

Bulb finish and other
important information.

Average rated life
expressed in hours.

LUMENS

Represents average
light output.

BEAM
SPREAD

Indicates the
beam angle or
beam spread
of a bulb,
measured in
degrees.

TOC

INCANDESCENT LAMPS
General Service
S6
S11
Cand.

C7/C9
Cand.

Bulb

Base

Product
Number

Pkg.
Qty.

Volts

Lumens

Avg.
Life

Design
Filament

MOL

Beam
Spread

Clear

25/1000

130

16

1000

C-3A

2.12”

-

C7AMB5T

Transparent Amber

25/1000

130

-

1000

C-3A

2.12”

-

7104

C7BLU5C

Ceramic Blue

25/1000

130

-

1000

C-3A

2.12”

-

7106

C7BLU5T

Transparent Blue

25/1000

130

-

1000

C-3A

2.12”

-

7108

C7GRN5C

Ceramic Green

25/1000

130

-

1000

C-3A

2.12”

-

7110

C7GRN5T

Transparent Green

25/1000

130

-

1000

C-3A

2.12”

-

7112

C7ORG5C

Ceramic Orange

25/1000

130

-

1000

C-3A

2.12”

-

7114

C7RED5C

Ceramic Red

25/1000

130

-

1000

C-3A

2.12”

-

7116

C7RED5T

Transparent Red

25/1000

130

-

1000

C-3A

2.12”

-

7118

C7WH5C

Ceramic White

25/1000

130

-

1000

C-3A

2.12”

-

9042

S6CL6

Clear

25/2000

130

30

1500

C-7A

1.87”

-

9043

S6CL6/145V

Clear

25/2000

145

30

1500

C-7A

1.87”

-

7016

C7CL7

Clear

25/1000

130

40

1000

C-3A

2.12”

-

C7WH7/NL

White Night Light

25/2000

130

-

1000

C-3A

2.12”

-

7050

C9CL7

Clear

25/1000

130

40

3000

C-3A

3.00”

-

7120

C9AMB7T

Transparent Amber

25/1000

130

-

3000

C-3A

3.00”

-

7122

C9BLU7C

Ceramic Blue

25/1000

130

-

3000

C-3A

3.00”

-

7124

C9BLU7T

Transparent Blue

25/1000

130

-

3000

C-3A

3.00”

-

7126

C9GRN7C

Ceramic Green

25/1000

130

-

3000

C-3A

3.00”

-

7128

C9GRN7T

Transparent Green

25/1000

130

-

3000

C-3A

3.00”

-

7130

C9ORG7C

Ceramic Orange

25/1000

130

-

3000

C-3A

3.00”

-

7132

C9RED7C

Ceramic Red

25/1000

130

-

3000

C-3A

3.00”

-

7134

C9RED7T

Transparent Red

25/1000

130

-

3000

C-3A

3.00”

-

7017

S11CL7.5

Clear

25/500

130

45

1500

C-7A

2.25”

-

7024

S11GRN7.5C

Ceramic Green

25/500

130

-

1500

C-7A

2.25”

-

7026

S11ORG7.5C

Ceramic Orange

25/500

130

-

1500

C-7A

2.25”

-

7019

S11RED7.5C

Ceramic Red

25/500

130

-

1500

C-7A

2.25”

-

7020

S11WH7.5C

Ceramic White

25/500

130

-

1500

C-7A

2.25”

-

7028

S11YEL7.5C

Ceramic Yellow

25/500

130

-

1500

C-7A

2.25”

-

9045

S11CL10

Clear

25/500

130

80

1500

C-7A

2.48”

-

Footnotes

Product Code

Description

7014

C7CL4

7102

4 WATT
C7

Cand.

5 WATT
C7

Cand.

6 WATT
S6

Cand.

7 WATT
C7

Cand.

105204
C9

Int.

7.5 WATT
S11

Med.

10 WATT
S11

Int.

E Means this lamp meets Federal Minimum Efficiency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 137

INCANDESCENT LAMPS
General Service
T7

Bulb

Product
Number

PAR36

A15
A19

T6

S14

T6.5

Pkg.
Qty.

Volts

Lumens

Avg.
Life

Design
Filament

MOL

Beam
Spread

Clear

25/250

130

80

5000

C-9

3.50”

-

S14FR11

Frost

25/250

130

75

3000

C-9

3.50”

-

9056

S14AMB11T

Transparent Amber

25/250

130

-

3000

C-9

3.50”

-

9076

S14BLU11C

Ceramic Blue

25/250

130

-

3000

C-9

3.50”

-

9055

S14BLU11T

Transparent Blue

25/250

130

-

3000

C-9

3.50”

-

9070

S14GRN11C

Ceramic Green

25/250

130

-

3000

C-9

3.50”

-

9054

S14GRN11T

Transparent Green

25/250

130

-

3000

C-9

3.50”

-

105334

S14RED11C

Ceramic Red

25/250

130

-

3000

C-9

3.50”

-

9052

S14RED11T

Transparent Red

25/250

130

-

3000

C-9

3.50”

-

9058

S14WH11C

Ceramic White

25/250

130

-

3000

C-9

3.50”

-

105336

S14YEL11C

Ceramic Yellow

25/250

130

-

3000

C-9

3.50”

-

9053

S14YEL11T

Transparent Yellow

25/250

130

-

3000

C-9

3.50”

-

6013

A15CL15

Clear

20/120

130

95

3000

C-9

3.50”

-

6014

A15FR15

Frost

20/120

130

90

3000

C-9

3.50”

-

9030

T6CL15/CAN

Clear

25/500

130

90

2000

C-5A

3.06”

-

9021

T6CL15/145V

Clear

25/500

145

80

2000

C-5A

3.06”

-

Cand.

9039

T7CL15CAN

Clear

25/1000

120

100

2000

C-5A

2.25”

-

BA15d

9038

T7CL15DC

Clear

25/1000

120

100

2000

C-5A

2.35”

-

Int.

9037

T7CL15INT

Clear

25/1000

120

100

2000

C-5A

2.35”

-

12

12

260

5000

C-6

2.75”

12°

Base

Footnotes

Product Code

Description

9051

S14CL11

9057

11 WATT
S14

Med.

15 WATT
A15

T6

T7

Med.

Cand.

20 WATT
PAR36 Screw
Term.

T6.5

BA15d

Int.

107788

$,17

HP36NSP20/HX

Narrow Spot HaloXen®

107790

$,17

HP36VNSP20/HX

Very Narrow Spot HaloXen

12

12

260

5000

C-6

2.75”

5°

107792

$,17

HP36WFL20/HX

Wide Flood HaloXen

12

12

260

5000

C-6

2.75”

32°

9022

T6.5CL20DC

Clear

25/500

130

150

2500

C-8

5.56”

-

9023

T6.5FR20DC

Frost

25/500

130

150

2500

C-8

5.56”

-

9019

T6.5CL20INT

Clear

25/500

130

150

2500

C-8

5.50”

-

9028

T6.5FR20INT

Frost

25/500

130

150

2500

C-8

5.50”

-

6016

A15CL25

Clear

20/120

130

130

3000

C-9

3.50”

-

6015

A15FR25

Frost

20/120

130

120

3000

C-9

3.50”

-

6318

A19CL25/5

Clear

120

130

175

5000

C-9

4.25”

-

A19FR25

Frost

120

130

160

1500

C-9

4.25”

-

A19FR25/5

Frost

120

130

150

5000

C-9

4.25”

-

A19FR25/12V

Frost

12/240

12

240

2000

C-6

4.25”

-

A19BLU25T

Transparent Blue

12/120

130

-

2000

C-9

4.25”

-

®

®

25 WATT
A15

A19

Med.

Med.

103700

Al

6319
101159
101150

138

TOC

10

E Means this lamp meets Federal Minimum Efficiency standards.
Incandescent lamp symbols, footnotes and abbreviations are located on pages 151-153.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

INCANDESCENT LAMPS
General Service
PAR30
PAR30L

Bulb

Base

Product
Number

A19
A21

T6.5

T8
T10

R20

PAR20

PAR36

C11

R14

S11

Pkg.
Qty.

Volts

Lumens

Avg.
Life

Design
Filament

MOL

Beam
Spread

Transparent Green

12/120

130

-

2000

C-9

4.25”

-

A19RED25C

Ceramic Red

12/120

130

-

2000

C-9

4.25”

-

101154

A19RED25T

Transparent Red

12/120

130

-

2000

C-9

4.25”

-

101124

A19RS25/CS

CoverShield®

20/120

130

-

2000

C-9

4.25”

-

6338

A19YEL25C

Ceramic Yellow

12/120

130

-

2000

C-9

4.25”

-

101156

A19YEL25T

Transparent Yellow

12/120

130

-

2000

C-9

4.25”

-

20003

C11ANT25

Antique Oil-Rubbed finish

10/100

120

120

3000

Z-Shape

4.00”

-

Footnotes

Product Code

Description

101152

A19GRN25T

6335

25 WATT continued
A19

C11

Med.

Cad.

PAR36 Screw
Term.

R14

PAR36NSP25/M

Narrow Spot Major

1/12

12

150

2000

C-6

2.75”

9°

14556

10

PAR36VWFL25/M

Very Wide Flood Major

1/12

12

150

2000

C-6

2.75”

55°

65205

10

1/12

12

150

2000

C-6

2.75”

25x37

PAR36WFL25

Wide Flood

9104

Flood

25/250

130

150

1500

CC-2V

2.64”

-

9103

R14MED25

Flood

25/250

130

150

1500

CC-2V

2.64”

-

Int.

9048

S11N25

Clear High-Intensity

25/500

130

200

1500

CC-2V

2.48”

-

BA15d

9025

T6.5CL25DC

Clear

25/500

130

180

2500

C-8

5.56”

-

Int.

9018

T6.5CL25INT

Clear

25/500

130

180

2500

C-8

5.50”

-

BA15d

9034

T8CL25DC

Clear

25/500

130

180

2500

C-8

2.63”

-

Int.

9032

T8CL25INT

Clear

25/500

130

180

2500

C-8

2.63”

-

Med.

9012

T10CL25

Clear

25/200

130

180

2500

C-5V

5.00”

-

9013

T10FR25

Frost

25/200

130

180

2500

C-5V

5.00”

-

Med.
S11
T6.5

T10

10

R14INT25

Int.

T8

14554

29 WATT
A19

Med.

76005

E

$

A19CL29/H

Clear

12/120

120

430

1000

CC-8

4.25”

-

76001

E

$

A19SW29/H

Soft White

12/120

120

430

1000

CC-8

4.25”

-

R20FL30

Flood

10/100

130

140

3000

C-9

3.93”

-

R20FL30/CS

Flood CoverShield

10/100

130

140

3000

C-9

3.93”

-

A21SW3W100

Soft White 3-Way 30/70/100

12/60

130

260/
650/940

2500

CC-8

5.25”

-

HP20NFL35

Narrow Flood Prism®

15

130

450

3000

CC-8

3.07”

30°

1/12

12

540

5000

C-6

2.75”

12°

1/12

12

540

5000

C-6

2.75”

5°

1/12

12

540

5000

C-6

2.75”

32°

1/12

24

500

5000

CC-6

2.75”

32°

30 WATT
R20

Med.

9110

6

10102

®

30/70/100 WATT
A21

Med.

8009

1

35 WATT
PAR20 Med.

107610

N,$,18

PAR36 Screw
Term.

107794

$,17

HP36NSP35/HX

Narrow Spot HaloXen

107796

$,17

HP36VNSP35/HX

Very Narrow Spot HaloXen

107798

$,17

HP36WFL35/HX

Wide Flood HaloXen

70306

$,17

HP36WFL35/24V

Wide Flood

®

®

®

E Means this lamp meets Federal Minimum Efficiency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 139

INCANDESCENT LAMPS
General Service
PAR20
PAR30
PAR30L

Bulb

Base

Product
Number

Footnotes

Product Code

Description

A15
A19
A21

PAR38

R14
R16

Pkg.
Qty.

Volts

Lumens

Avg.
Life

Design
Filament

MOL

Beam
Spread

39 WATT
PAR20 Med.

PAR30 Med.

PAR30L Med.

PAR38 Med.

70343

$,,17

HP20NFL39/HX

Narrow Flood HaloXen®

1/15

120

530

2000

CC-8

3.23”

30°

70354

$,,17

HP20NFL39/HX/130

Narrow Flood HaloXen

1/15

130

530

2000

CC-8

3.23”

30°

®

1/15

120

530

2000

CC-8

3.62”

30°

1/15

130

530

2000

CC-8

3.62”

30°

1/15

120

530

2000

CC-8

4.75”

36°

70347

$,,17

HP30FL39/HX

Flood HaloXen

70353

$,,17

HP30FL39/HX/130

Flood HaloXen®

70344

$,,17

HP30FL39L/HX

Flood HaloXen®

70204

$,,17

HP30WFL39L/HX

Wide Flood HaloXen

70203

$,,17

70356

®

1/15

120

530

2000

CC-8

4.75”

50°

HP30SP39L/HX

Spot HaloXen

®

1/15

120

530

2000

CC-8

4.75”

15°

$,,17

HP30FL39L/HX/130

Flood HaloXen

®

1/15

130

530

2000

CC-8

4.75”

36°

70340

$,,17

HP38FL39/HX

Flood HaloXen

®

70404

$,,17
$,,17

70355

®

1/15

120

530

2000

CC-8

5.31”

30°

HP38SP39/HX

Spot HaloXen

®

1/15

120

530

2000

CC-8

5.31”

10°

HP38FL39/HX/130

Flood HaloXen

1/15

130

530

2000

CC-8

5.31”

30°

A15CL40/E12

Clear

20/120

120

350

2000

C-9

3.50”

-

®

40 WATT
A15

A19

Cand.

10005
10006

X

A15WH40/E12

White

20/120

120

310

2000

C-9

3.50”

-

Int.

10009

X

A15CL40/E17

Clear

20/120

120

350

2000

C-9

3.50”

-

Med.

6017

A15CL40

Clear

20/120

130

300

3000

C-9

3.50”

-

90300

A15CL40/CSTF

Clear CoverShield PFA

20/120

130

300

3000

C-9

3.50”

-

6018

A15FR40

Frost

20/120

130

290

3000

C-9

3.50”

-

6146

A15RS40/CS

CoverShield

20/120

130

-

1500

C-9

3.50”

-

A19CL40

Clear

120

130

340

1500

C-9

4.25”

-

A19CL40/5

Clear

120

130

320

5000

C-9

4.25”

-

A19FR40

Frost

120

130

325

1500

C-9

4.25”

-

6320

A19FR40/5

Frost

120

130

275

5000

C-9

4.25”

-

6220

A19SW40/120

Soft White

120

120

300

1500

CC-6

4.25”

-

8013

A19BG40

Yellow Bug

20/120

130

-

2000

C-9

4.25”

-

X

A19BLU40T

Transparent Blue

12/120

130

-

2000

C-9

4.25”

-

X

A19GRN40T

Transparent Green

12/120

130

-

2000

C-9

4.25”

-

101155

A19RED40T

Transparent Red

12/120

130

-

2000

C-9

4.25”

-

101125

A19RS40/CS

CoverShield®

20/120

130

-

2000

C-9

4.25”

-

A19YEL40C

Ceramic Yellow

12/120

130

-

2000

C-9

4.25”

-

6/48

120

130

3000

Quad
Loop

5.00”

-

Med.

103710

L, Al

6324
103702

101151
101153

6354

L, Al

X

®

®

A21

Med.

20002

A21ANT40

Antique Oil-Rubbed finish

R14

Int.

9101

R14INT40

Flood

25/250

130

260

1500

CC-2V

2.64”

-

Med.

9100

R14MED40

Flood

25/250

130

260

1500

CC-2V

2.64”

-

Med.

9127

R16MED40

Flood

25/500

130

235

3000

C-9

3.66”

-

R16

140

TOC

129127

R16MED40/120

Flood

25/500

120

235

3000

C-9

3.66”

-

104106

R16SP40

Spot

25/500

130

235

3000

CC-2V

3.66”

-

E Means this lamp meets Federal Minimum Efficiency standards.
Incandescent lamp symbols, footnotes and abbreviations are located on pages 151-153.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

INCANDESCENT LAMPS
General Service
T10
T14

Bulb

Base

PAR30
PAR30L

Product
Number

ST18

BR30

Footnotes

ER30

T6.5

PAR38

A19
A21

G30

PAR36

PAR16

S11

R20

Pkg.
Qty.

Volts

Lumens

Avg.
Life

Design
Filament

MOL

Beam
Spread

Clear

25/500

130

350

2500

C-8

5.50”

-

T10CL40

Clear

25/200

130

280

2500

C-5V

5.00”

-

Product Code

Description

T6.5CL40INT

9014
9015

40 WATT continued
T6.5

Int.

T10

Med.

106111

T10FR40

Frost

25/200

130

280

2500

C-5V

5.00”

-

106228

T10CL40/CS

CoverShield®

25/200

130

-

-

C-5V

5.00”

-

5.13”

-

6.75”

-

2.48”

-

5.16”

-

4.25”

-

G30

Med.

20004

G30ANT40

Antique Oil-Rubbed finish

50

120

140

3000

G40

Med.

20005

G40ANT40

Antique Oil-Rubbed finish

12

120

140

3000

S11

Int.

9050

S11N40

Clear High-Intensity

25/500

130

370

1500

ST18

Med.

20006

ST18ANT40

Antique Oil-Rubbed finish

10/100

120

135

3000

T14

Med.

20007

T14ANT40

Antique Oil-Rubbed finish

10/100

120

135

3000

Squirrel
Cage
Squirrel
Cage
CC-2V
Squirrel
Cage
Squirrel
Cage

43 WATT
A19

Med.

76006

E

$

A19CL43/H

Clear

12/120

120

750

1000

CC-8

4.25”

-

76004

E

$

A19SW43/H

Soft White

12/120

120

750

1000

CC-8

4.25”

-

HP16NFL45

Narrow Flood Prism®

15

130

500

3000

CC-2V

3.07”

30°

R20FL45

Flood

10/100

130

450

3000

C-9

3.93”

-

A19FR50/12V

Frost

12/240

12

580

1500

C-6

4.25”

-

A19RS50

Rough Service

20/120

130

580

2500

C-9

4.25”

-

BR30FL50

Flood

24

130

300

5000

C-9

5.37”

-

45 WATT
PAR16 Med.

107502

N, $,18

R20

10100

6

101160

10

Med.

50 WATT
A19

Med.

101123
BR30

Med.

104058

ER30

Med.

9113

5,7

ER30FL50/P5

Flood Prism Long Life Plus™

12/60

130

360

5000

C-9M

6.25”

-

107782

17

HP36NSP50/HX

Narrow Spot HaloXen

1/12

12

910

5000

C-6

2.75”

12°

107784

17

HP36VNSP50/HX

Very Narrow Spot HaloXen

1/12

12

910

5000

C-6

2.75”

5°

107786

17

HP36WFL50/HX

Wide Flood HaloXen

1/12

12

910

5000

C-6

2.75”

32°

10

PAR36WFL50

Wide Flood

1/12

12

330

2000

C-6

2.75”

39x27

HP38FL50/S/HX

Silver PAR Flood HaloXen®

1/15

120

920

1500

CC-8

5.31”

30°

PAR36 Screw
Term.

6

65210

®

®

®

®

PAR38 Med.

70350

R20

104200

6

R20AMB50

Amber

10/100

130

-

2500

C-9

3.93”

-

9146

6

R20BLU50

Blue

10/100

130

-

2500

C-9

3.93”

-

9150

6

R20DPNK50

Dawn Pink

10/100

130

-

2500

C-9

3.93”

-

9141

6

R20GRN50

Green

10/100

130

-

2500

C-9

3.93”

-

9108

6

R20PNK50

Pink

10/100

130

-

2500

C-9

3.93”

-

9142

6

R20RED50

Red

10/100

130

-

2500

C-9

3.93”

-

104016

6

R20FL50/CS

CoverShield®

10/100

130

-

2000

C-9

3.93”

-

Med.

E

,17

E Means this lamp meets Federal Minimum Efficiency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 141

INCANDESCENT LAMPS
General Service
A15
A19
A21

Bulb

Base

Product
Number

Footnotes

Pkg.
Qty.

Volts

Soft White 3-Way
50/100/150

12/60

130

A21FR50/150/ND

Frost 3-Way 50/100/150
Neodymium PureLite®

12/60

120

12/120

120

Product Code

Description

A21SW3W150

50/100/150 WATT
A21

Med.

8010

1

PAR30
PAR30L

PAR38

Avg.
Life

Design
Filament

MOL

Beam
Spread

2500

CC-8

5.25”

-

5000

CC-8

5.25”

-

1050

1000

CC-8

4.25”

-

Lumens

560/
1200/
1760
380/
1000/
1380

101240

X,N,1

76007

E

$

A19CL53/H

Clear

76002

E

$

A19SW53/H

Soft White

12/120

120

1050

1000

CC-8

4.25”

-

,17

HP30FL53/XIR

®

Flood XIR

1/15

120

1050

3500

CC-8

3.62”

30°

,17

HP30FL53L/XIR

Flood XIR

®

1/15

120

930

3500

CC-8

4.75”

30°

,17

HP38FL53/XIR

Flood XIR

®

1/15

120

960

3500

CC-8

5.31”

25°

A19FR54/10

Frost Prism® Ultra Life®

20/120

130

450

10000

C-9M

4.25”

-

10007

A15CL60/E12

Clear

20/120

120

530

2000

C-9

3.50”

-

10008

A15WH60/E12

White

20/120

120

520

2000

C-9

3.50”

-

6117

A15CL60

Clear

20/120

130

530

3000

C-9

3.50”

-

A15CL60/120

Clear

20/120

120

620

3000

C-9

3.50”

-

A15CL60/ND

Clear Neodymium PureLite

10/50

120

530

5000

CC-9

3.50”

-

6118

A15FR60

Frost

20/120

130

520

3000

C-9

3.50”

-

6147

53 WATT
A19

Med.

PAR30 Med.

70310

E

PAR30L Med.

70311

E

PAR38 Med.

70312

E

54 WATT
A19

Med.

288584

$

60 WATT
A15

Cand.

Med.

126117
101234

A19

Med.

103712

X, N

L, Al

®

A15RS60/CS

CoverShield

20/120

130

-

1500

C-9

3.50”

-

A19CL60

Clear

120

130

620

1500

C-9

4.25”

-

120

120

590

1500

CC-6

4.25”

-

120

130

545

5000

C-9

4.25”

-

20/120

120

480

10000

C-9M

4.25”

-

20/120

120

600

5000

CC-6

4.25”

-

12/120

130

-

2500

C-9

4.25”

-

®

6225

L

A19CL60/120

Clear

6325

L

A19CL60/5

Clear

103010

L

A19CL60/P10

Clear Prism Ultra Life

101242

N

A19CL60/ND

Clear Neodymium PureLite

101180

3

A19CL60/SB

Clear Silver Bowl Prism

103704

L, Al

®

®

®

®

A19FR60

Frost

120

130

590

1500

C-9

4.25”

-

6321

L

A19FR60/5

Frost

120

130

510

5000

C-9

4.25”

-

103024

L

A19FR60/P10

Frost Prism® Ultra Life®

20/120

120

480

10000

C-9M

4.25”

-

101194

N

A19FR60/ND

Frost Neodymium PureLite

20/120

120

600

5000

CC-6

4.25”

-

101184

3

A19FR60/SB

Inside Frost Silver Bowl Prism

12/120

130

-

5000

C-9

4.25”

-

6221

L

A19SW60/120

Soft White

120

120

530

1500

C-9

4.25”

-

A19BG60

Yellow Bug

20/120

130

-

2000

C-9

4.25”

-

A19GRO60

Plant Grow

12/120

120

480

2000

C-9

4.25”

-

A19RED60C

Ceramic Red

12/120

130

-

2000

C-9

4.25”

-

8011
101196
6352

X

®

®

E Means this lamp meets Federal Minimum Efficiency standards.
Incandescent lamp symbols, footnotes and abbreviations are located on pages 151-153.

142

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

INCANDESCENT LAMPS
General Service
PAR30
PAR30L

Bulb

Base

Product
Number

A19

PAR16

Footnotes

T10

BR30
BR40

PAR38

Pkg.
Qty.

Volts

Lumens

Avg.
Life

Design
Filament

MOL

Beam
Spread

Rough Service

20/120

130

780

2500

C-9

4.25”

-

A19RS60/CS

CoverShield

20/120

130

-

2000

C-9

4.25”

-

Product Code

Description

6151

A19RS60

6141

60 WATT continued
A19

Med.

A19YEL60C

Ceramic Yellow

12/120

130

-

2000

C-9

4.25”

-

107616

N,$,18

HP16NFL60

Narrow Flood Prism®

15

130

550

3000

CC-8

3.07”

30°

107850

N,$,18

HP16NFL60/120

Narrow Flood Prism®

15

120

550

3000

CC-8

3.07”

30°

107504

N,$,18

HP16NSP60

Narrow Spot Prism

15

130

550

3000

CC-8

3.07”

10°

T10CL60

Clear

25/200

130

420

2500

C-5V

5.00”

-

T10FR60

Frost

25/200

130

420

2500

C-5V

5.00”

-

1/15

120

1090

1500

CC-8

3.62”

30°

1/15

120

1090

1500

CC-8

4.75”

36°

6356
PAR16 Med.

T10

Med.

®

9016
9017

®

PAR30 Med.

70345

E

PAR30L Med.

70342

E

 $,17

HP30FL60L/S/HX

Silver PAR Flood HaloXen

70349

E

 $,17

HP30WFL60L/S/HX

Silver PAR Wide Flood HaloXen

1/15

120

1090

1500

CC-8

4.75”

50°

70348

E

 $,17

HP30SP60L/S/HX

Silver PAR Spot HaloXen®

1/15

120

1090

1500

CC-8

4.75”

15°

E

 $,17

HP38FL60/S/HX

Siver PAR Flood HaloXen

1/15

120

1090

1500

CC-8

5.31”

30°

PAR38 Med.

70341

 $,17

HP30FL60/S/HX

Silver PAR Flood HaloXen

®

®

®

®

65 WATT
BR30

BR40

Med.

Med.

104070

6

BR30FL65

Flood

24

130

580

5000

C-9

5.37”

-

124070

6

BR30FL65/120

Flood

24

120

510

5000

C-9

5.37”

-

75009

,19

BR30FL65/H

Flood

24

120

750

2500

CC-8

5.37”

-

103620

6

BR30FL65/P5

Flood Prism Long Life Plus

24

130

480

5000

C-9M

5.37”

-

BR30FL65/P10

®

Flood Prism Ultra Life

24

120

420

10000

C-9M

5.37”

-

BR30FL65/20

Flood Prism® Ultra Life®

24

120

480

20000

C-9M

5.37”

-

24

130

-

5000

C-9

5.37”

-

12/24

130

-

5000

C-9

5.37”

-

12/24

130

-

5000

C-9

5.37”

-

12/24

130

-

5000

C-9

5.37”

-

®

103110

6

103528

N, 6

404014

6

BR30SP65/5

Spot

404028

6

BR30AMB65/5

Amber Prism

404030

6

BR30BLU65/5

Blue Prism

404031

6

BR30DPNK65/5

Dawn Pink Prism

404039

6

BR30GRN65/5

Green Prism

404046

6

BR30PNK65/5

Pink Prism

404049

6

BR30RED65/5

Red Prism

404051

6

BR30FL65/CS

CoverShield® Prism®

404053

6

BR30YEL65/5

Yellow Prism®

404076

6

BR40FL65/P5

75010

,19

288580

11

®

®

®

®

12/24

130

-

5000

C-9

5.37”

-

®

12/24

130

-

5000

C-9

5.37”

-

®

12/24

130

-

5000

C-9

5.37”

-

1/24

130

-

5000

C-9

5.37”

-

12/24

130

-

5000

C-9

5.37”

-

Flood Prism Long Life Plus

24

130

550

5000

C-9M

6.56”

-

BR40FL65/H

Flood

24

120

750

2500

CC-8

6.56”

-

A19FR68/10

Frost Prism® Ultra Life®

20/120

130

630

10000

C-9M

4.25”

-

®

®

68 WATT
A19

Med.

E Means this lamp meets Federal Minimum Efficiency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 143

INCANDESCENT LAMPS
General Service
A19
A21

PAR38

Bulb

Base

Product
Number

Footnotes

Product Code

Description

Pkg.
Qty.

Volts

Lumens

Avg.
Life

Design
Filament

MOL

Beam
Spread

70 WATT
PAR38 Med.

70346
70352

E

 $,17

HP38FL70/S/HX

Silver PAR Flood HaloXen®

1/15

120

1350

1500

CC-8

5.31”

30°

E

 $,17

HP38SP70/S/HX

Silver PAR Spot HaloXen

1/15

120

1350

1500

CC-8

5.31”

10°

®

72 WATT
A19

Med.

76000

E

$

A19CL72/H

Clear

12/120

120

1490

1000

CC-8

4.25”

-

76003

E

$

A19SW72/H

Soft White

12/120

120

1490

1000

CC-8

4.25”

-

A19CL75

Clear

120

130

860

1500

C-9

4.25”

-

A19CL75/5

Clear

120

130

700

5000

C-9

4.25”

-

A19FR75

Frost

120

130

820

1500

C-9

4.25”

-

75 WATT
A19

Med.

103714

L, Al

6326

L

103706

A21

Med.

L, Al

6322

L

A19FR75/5

Frost

120

130

680

5000

C-9

4.25”

-

6222

L

A19SW75/120

Soft White

120

120

780

1500

CC-6

4.25”

-

6152

A19RS75

Rough Service

20/120

130

1100

2500

C-9

4.25”

-

6142

A19RS75/CS

CoverShield®

20/120

130

-

2000

C-9

4.25”

-

A21FR75/ND

Frost Neodymium PureLite®

12/60

120

710

5000

CC-6

5.00”

-

HP38FL80/S/HX

Silver PAR Flood HaloXen®

1/15

120

1580

1500

CC-8

5.31”

30°

A19CL100/5

Clear

120

130

1000

5000

C-9

4.25”

-

A19CL100/SB

Clear Silver Bowl Prism

12/120

130

830

5000

C-9

4.25”

-

120

130

980

5000

C-9

4.25”

-

20/120

120

870

10000

C-9M

4.25”

-

120

120

1050

1500

CC-6

4.25”

-

20/120

130

1150

2500

C-9

4.25”

-

20/120

130

-

2500

C-9

4.25”

-

12/60

120

1050

5000

CC-6

5.00”

-

12/60

130

1050

5000

C-9M

5.00”

-

12/60

120

1050

5000

CC-6

5.00”

-

12/60

130

800

5000

C-9

5.00”

-

12/60

130

-

5000

C-9M

5.00”

-

101248

N

80 WATT
PAR38 Med.

70351

E

 $,17

100 WATT
A19

Med.

6327
101182

A21

Med.

L
3,8

®

6323

L

A19FR100/5

Frost

103028

L

A19FR100/P10

Frost Prism Ultra Life

6223

X

A19SW100/120

Soft White

6153

A19RS100

Rough Service

6143

A19RS100/CS

CoverShield

®

®

®

101246

N

A21CL100/ND

Clear Neodymium PureLite

103576

X

A21FR100/P5

Frost Prism Long Life Plus™

101197

N

A21FR100/ND

Frost Neodymium PureLite

101190

3,8

A21FR100/SB

Inside Frost Silver Bowl Prism

A21RS100/P5/CS

CoverShield Prism

6041

®

®

®

®

®

®

E Means this lamp meets Federal Minimum Efficiency standards.
Incandescent lamp symbols, footnotes and abbreviations are located on pages 151-153.

144

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

INCANDESCENT LAMPS
General Service
PAR38
PAR46
Side
Prong

Bulb

Base

Product
Number

BR30
BR38
BR40

A21

Footnotes

PAR38

PS25

R20

Pkg.
Qty.

Volts

Lumens

Avg.
Life

Design
Filament

MOL

Beam
Spread

Clear Pool Lamp

12/24

12

1200

2000

C-6

5.37”

-

Product Code

Description

BR30CL100/12V

100 WATT continued
BR30

Med.

104026

6,10

BR38

Med.

404112

9

BR38AMB100

Amber Flood

12/24

130

-

5000

C-9

5.50”

-

404113

9

BR38BLU100

Blue Flood

12/24

130

-

5000

C-9

5.50”

-

404114

9

BR38GRN100

Green Flood

12/24

130

-

5000

C-9

5.50”

-

404116

9

BR38RED100

Red Flood

12/24

130

-

5000

C-9

5.50”

-

404119

9

BR38YEL100

Yellow Flood

12/24

130

-

5000

C-9

5.50”

-

104020

2,6,10

R20CL100/12V

Clear Pool Lamp

10/100

12

950

2000

C-6

3.55”

-

R20

Med.

100/200/300 WATT
PS25

Mog.

8005

1

PS25SW3W300

Soft White 3-Way
100/200/300 Prism®

12/60

120

1200/
2600/
3800

1200

CC-6

6.93”

-

404065

6

BR40FL120/5/CS

CoverShield®

1/24

120

-

5000

C-9

6.56”

-

65058

X,4,13

PAR38/3SP120

Spot

1/12

120

1370

2000

CC-6

4.30”

18°

65059

X,4,13

PAR38/3FL120

Flood

1/12

120

1370

2000

CC-6

4.30”

30°

204035

6,11

BR40CL125/1

Clear Infrared Prism®

12

120

-

6000

C-9

6.56”

-

A21RS150/P5/CS

CoverShield®

1/60

130

-

5000

C-9M

5.00”

-

1/60

130

-

5000

C-9M

6.93”

-

12

120

-

5000

C-9

6.56”

-

1/12

120

2270

2000

CC-13

4.00”

25x15

1/12

120

2270

2000

CC-13

4.00”

12x8

1/60

130

-

5000

C-9M

6.93”

-

120 WATT
BR40

Med.

PAR38 Side
Prong

125 WATT
BR40

Med.

150 WATT
A21
PS25

Med
Med.

6043
401345

3

PS25CL150/P5/CS

CoverShield® Prism®
Long Life Plus™

104012

X

R40GRO150

Plant Grow

65064

4,13

PAR46/3MFL200

Medium Flood

65065

4,13

PAR46/3NSP200

Narrow Spot

PS25CL200/P5/CS

CoverShield Prism
Long Life Plus™

200 WATT
PAR46 Side
Prong
PS25

Med.

401347

3

404068

6,11

404066

6,11,16

®

®

250 WATT
BR40

Med.

PAR38 Med.

R40

Med.

BR40CL250/1

Clear Heat Prism®

12

120

-

5000

C-9

6.56”

-

BR40CL250/1/CSTF

Clear CoverShield® PFA Prism®

1/12

120

-

5000

C-9

6.56”

-

15558

Q250PAR/FL

Flood Major

1/6

120

3600

4200

CC-8

5.31”

30°

15526

Q250PAR/SP

Spot Major

1/6

120

3600

4200

CC-8

5.31”

10°

R40RED250/10

Red Heat Prism

12

120

-

5000

C-9

6.56”

-

R40RED250/10/CSTF

Red CoverShield PFA Prism

1/12

120

-

5000

C-9

6.56”

-

104044

6,11

404071

6,11,16

®

®

®

E Means this lamp meets Federal Minimum Efficiency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 145

INCANDESCENT LAMPS
General Service
PS25
PS30
PS35

Bulb

Base

Product
Number

Footnotes

Product Code

PAR56/64
End Prong

R40

BR40

G30

Description

Pkg.
Qty.

Volts

Lumens

Avg.
Life

Design
Filament

MOL

Beam
Spread

300 WATT
PAR56 Mog.
End
Prong

PS25

PS30

PS35

R40

65220

4,13

PAR56MFL300

Medium Flood

1/12

120

3840

2000

CC-13

5.00”

25x11

65042

4,13

PAR56NSP300

Narrow Spot

1/12

120

3840

2000

CC-13

5.00”

10x8

PAR56WFL300

Wide Flood

1/12

120

3840

2000

CC-13

5.00”

35x20

PAR56WFL300/12

Wide Flood

1/12

12

6000

1000

C-6

4.50”

35x20

65230

4,13

Screw
Term.

65225

4,10,13

Med.

401305

PS25CL300/P5

Clear Prism® Long Life Plus™

12/60

130

3600

5000

C-9M

6.93”

-

401306

PS25FR300/P5

Frost Prism Long Life Plus™

12/60

130

3600

5000

C-9M

6.93”

-

401308

PS30CL300/P5

Clear Prism Long Life Plus™

12/60

130

3600

5000

C-9M

8.06”

-

401310

PS30FR300/P5

Frost Prism Long Life Plus™

12/60

130

3600

5000

C-9M

8.06”

-

401316

PS35CL300/P5

Clear Prism Long Life Plus™

6/24

130

3600

5000

C-9M

9.37”

-

401318

PS35FR300/P5

Frost Prism Long Life Plus™

6/24

130

3600

5000

C-9M

9.37”

-

Med.

Mog.

Med.

®

®

®

®

®

104040

5,7,10,12,14

R40FL300/12V

Flood Pool Lamp

12/24

12

3000

2000

C-6

6.56”

-

104035

5,7,12,14

R40FL300/HG

Flood Hard Glass

12/24

130

3000

3000

C-6

6.56”

-

104048

6,7,11,14

R40CL375

Clear Infrared Prism®

12/24

120

-

5000

C-9

6.56”

-

104050

6,7,11,14,16

R40CL375/CSTF

CoverShield PFA Prism

1/12

120

-

5000

C-9

6.56”

-

400G/FL

Clear

1/100

120

6800

800

C-5

5.10”

-

R40FL400/HG

Flood Hard Glass

12/24

120

4150

2000

CC-9

6.56”

-

PAR56Q500NSP

Narrow Spot

1/6

120

8000

4000

CC-6

5.00”

13x8

375 WATT
R40

Med.

®

®

400 WATT
G30

Med.

5508

R40

Med.

104038

5,12,14

843494

X 4,13

PAR64 Mog.
End
Prong

839409

13

PAR64MFL500

Medium Flood Major

1/12

120

6500

2000

CC-13

6.00”

23x11

14938

13

PAR64NSP500

Narrow Spot Major

1/12

120

6500

2000

CC-13

6.00”

12x7

R40

Med.

104042

5,12,14

R40FL500/HG

Flood Hard Glass

12/24

120

5400

2000

CC-9

6.56”

-

Mog.

821734

5,12,14

R40FL500/3FL

Flood Major

1/24

120

6500

2000

C-2V

7.25”

-

15

500 WATT
PAR56 Mog.
End
Prong

E Means this lamp meets Federal Minimum Efficiency standards.
Incandescent lamp symbols, footnotes and abbreviations are located on pages 151-153.

146

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

INCANDESCENT LAMPS
Decorative
CA5

Bulb

Base

B8

Product
Number

CA8
CA10

B10

Footnotes

C11
C15

F15

Product Code

Description

G16.5
G19.5
G25

Pkg.
Qty.

Volts

Lumens

Avg.
Life

Design
Filament

MOL

Beam
Spread

3 WATT
CA5

Cand.

2502

2

CFTC3

Clear Flicker Flame

25/500

130

-

1500

-

2.88”

-

CA10

Cand.

2008

2

CFC3

Clear Flicker Flame

25/500

130

-

1500

-

4.12”

-

Med.

2510

2

EFC3

Clear Flicker Flame

25/500

130

-

1500

-

4.12”

-

7.5 WATT
CA5

Cand.

2005

2

CFTC7.5

Clear

50/1000

130

40

1500

C-7A

2.88”

-

CA8

Cand.

2000

2

CFCP7.5

Clear 25mm

25/500

130

35

2000

C-7A

3.58”

-

15 WATT
B8

Cand.

1020

2

CTCP15

Clear 25mm

25/500

130

95

3000

C-7A

3.15”

-

B10

Cand.

1001

2

CTC15

Clear 32mm

25/500

130

95

3000

C-7A

3.87”

-

CA8

Cand.

2020

2

CFCP15

Clear 25mm

25/500

130

95

3000

C-7A

3.58”

-

CA10

Cand.

2001

2

CFC15

Clear 32mm

25/500

130

95

3000

C-7A

4.12”

-

G16.5

Cand.

4001

2

G16CL15

Clear

25/500

130

95

3000

C-7A

3.00”

-

4015

2

G16WH15

White

25/500

130

80

3000

C-7A

3.00”

-

25/500

130

220

3000

CC-2V

3.15”

-

25/500

130

220

3000

CC-2V

3.87”

-

25 WATT
B8

Cand.

1021

2

CTCP25

Clear 25mm

B10

Cand.

1003

2

CTC25

Clear 32mm

CTC25/ND

Clear Neodymium PureLite

10/50

120

140

5000

CC-2V

3.87”

-

CTF25

Frost 32mm

25/500

130

220

3000

CC-2V

3.87”

-

CTC25/E14

Clear 32mm

25/500

120

220

3000

CC-2V

3.87”

-

E14
Med.

101280

X,N,2

100192

2

121023

®

1012

2

ETC25

Clear 32mm

25/500

130

220

3000

CC-2V

3.87”

-

1013

2

ETF25

Frost 32mm

25/500

130

220

3000

CC-2V

3.87”

-

CA8

Cand.

2021

2

CFCP25

Clear 25mm

25/500

130

220

3000

CC-2V

3.58”

-

CA10

Cand.

2003

2

CFC25

Clear 32mm

25/500

130

220

3000

CC-2V

4.12”

-

2040

2,10

CFC25/12V

Clear 32mm

25/500

12

200

2000

C-6

4.12”

-

2004

2

CFF25

Frost 32mm

25/500

130

220

3000

CC-2V

4.12”

-

2012

2

EFC25

Clear 32mm

25/500

130

220

3000

CC-2V

4.12”

-

2013

2

EFF25

Frost 32mm

25/500

130

220

3000

CC-2V

4.12”

-

Med.

C11

Cand.

100210

2

C11SG25

Clear Spun Glow

25/500

130

-

1500

CC-2V

4.02”

-

C15

Med.

100214

2

C15SG25

Clear Spun Glow

25/500

130

-

1500

CC-2V

4.49”

-

F15

Med.

3001

2

F15CL25

Clear

25/250

130

140

3000

C-9

4.50”

-

3003

2

F15AMB25

Amber

25/250

130

-

3000

C-9

4.50”

-

4002

2

G16CL25

Clear

25/500

130

220

3000

CC-2V

3.00”

-

G16CL25/ND

Clear Neodymium PureLite

10/50

120

140

5000

CC-2V

3.00”

-

G16WH25

White

25/500

130

170

3000

CC-2V

3.00”

-

5001

G25CL25

Clear

10/100

130

150

3500

C-9

4.50”

-

5002

G25WH25

White

10/100

130

140

3500

C-9

4.50”

-

G16.5

Cand.

101270
4016
G25

Med.

X,N,2
2

®

E Means this lamp meets Federal Minimum Efficiency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 147

INCANDESCENT LAMPS
Decorative
G16.5
G19.5
G25
G40

Bulb

Base

Product
Number

Footnotes

Product Code

CA8
CA10

C11
C15

F15

Description

Pkg.
Qty.

Volts

Lumens

Avg.
Life

B10

B8

Design
Filament

MOL

Beam
Spread

40 WATT
B8

Cand.

1023

2

CTCP40

Clear 25mm

25/500

130

370

3000

CC-2V

3.15”

-

B10

Cand.

1006

2

CTC40

Clear 32mm

25/500

130

370

3000

CC-2V

3.87”

-

2

CTF40

Frost 32mm

25/500

130

370

3000

CC-2V

3.87”

-

CTC40/E14

Clear 32mm

25/500

130

370

3000

CC-2V

3.87”

-

25/500

130

370

3000

CC-2V

3.87”

-

1007
E14

121025

Med.

1015

2

ETC40

Clear 32mm

102148

2

ETC40/CS

Clear CoverShield

25/500

130

-

3000

CC-2V

3.87”

-

1016

2

ETF40

Frost 32mm

25/500

130

370

3000

CC-2V

3.87”

-

X, 2

®

CA8

Cand.

2023

2

CFCP40

Clear 25mm

25/500

130

370

3000

CC-2V

3.58”

-

CA10

Cand.

2006

2

CFC40

Clear 32mm

25/500

130

370

3000

CC-2V

4.12”

-

2007

2

CFF40

Frost 32mm

25/500

130

370

3000

CC-2V

4.12”

-

2015

2

EFC40

Clear 32mm

25/500

130

370

3000

CC-2V

4.12”

-

2016

2

EFF40

Frost 32mm

25/500

130

370

3000

CC-2V

4.12”

-

Med.

C11

Cand.

100212

2

C11SG40

Clear Spun Glow

25/500

130

-

1500

CC-2V

4.02”

-

C15

Med.

100216

2

C15SG40

Clear Spun Glow

25/500

130

-

1500

CC-2V

4.49”

-

100224

X, 2

C15SG40/AMB

Amber Spun Glow

25/500

130

-

2000

C-9

4.49”

-

F15

G16.5

Med.

Cand.

3004

2

F15CL40

Clear

25/250

130

300

3000

C-9

4.50”

-

3006

2

F15AMB40

Amber

25/250

130

-

3000

C-9

4.50”

-

4003

2

G16CL40

Clear

25/500

130

370

3000

CC-2V

3.00”

-

4017

2

G16WH40

White

25/500

130

320

3000

CC-2V

3.00”

-

X, 2

G19WH40

White

25/500

130

340

2000

C-9

3.50”

-

G25CL40

Clear

10/100

130

300

3500

C-9

4.50”

-

125003

G25CL40/120

Clear

10/100

120

300

3500

C-9

4.50”

-

102380

G25CL40/SB

Clear Silver Bowl Prism

10/100

130

-

3500

C-9

4.50”

-

G25WH40

White

10/100

130

270

3500

C-9

4.50”

-

G25WH40/120

White

10/100

120

280

3500

C-9

4.50”

-

5203

G40CL40

Clear

6/24

130

260

5000

C-9

6.93”

-

5202

G40WH40

White

6/24

130

240

5000

C-9

6.93”

-

G19.5

Med.

104504

G25

Med.

5003

5004
125004
G40

Med.

X

®

E Means this lamp meets Federal Minimum Efficiency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.

148

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

INCANDESCENT LAMPS
Decorative
B10

Bulb

Base

CA10

Product
Number

G16.5
G19.5
G25
G30
G40

C11
C15

Footnotes

Product Code

Description

Pkg.
Qty.

Volts

Lumens

Avg.
Life

Design
Filament

MOL

Beam
Spread

25/500

130

650

3000

CC-2V

3.87”

-

60 WATT
B10

Cand.

1009
101284

CA10

C15

Clear 32mm

CTC60/ND

Clear Neodymium PureLite

10/50

120

500

5000

CC-2V

3.87”

-

CTF60

®

1010

Frost 32mm

25/500

130

640

3000

CC-2V

3.87”

-

E14

121027

X

CTC60/E14

Clear 32mm

25/500

120

650

3000

CC-2V

3.87”

-

Med.

1018

2

ETC60

Clear 32mm

25/500

130

650

3000

CC-2V

3.87”

-

102146

2

ETC60/CS

Clear CoverShield

25/500

130

-

3000

CC-2V

3.87”

-

1019

2

ETF60

Frost 32mm

25/500

130

640

3000

CC-2V

3.87”

-

2009

2

CFC60

Clear 32mm

25/500

130

650

3000

CC-2V

4.12”

-

2010

2

CFF60

Frost 32mm

25/500

130

640

3000

CC-2V

4.12”

-

2018

2

EFC60

Clear 32mm

25/500

130

650

3000

CC-2V

4.12”

-

2019

2

EFF60

Frost 32mm

25/500

130

640

3000

CC-2V

4.12”

-

100213

2

C11SG60

Clear Spun Glow

25/500

130

-

1500

CC-2V

4.02”

-

100228

X

C11SG60/AMB

Amber Spun Glow

25/500

130

-

2000

CC-2V

4.02”

-

100218

2

C15SG60

Clear Spun Glow

25/500

130

-

1500

CC-2V

4.49”

-

100226

X

C15SG60/AMB

Amber Spun Glow

25/500

130

-

2000

C-9

4.49”

-

4004

2

G16CL60

Clear

25/500

130

650

3000

CC-2V

3.00”

-

4018

2

G16WH60

White

25/500

130

560

3000

CC-2V

3.00”

-

104506

2

G19WH60

White

25/500

130

550

1500

C-9

3.50”

-

G25CL60

Clear

10/100

130

550

3500

C-9

4.50”

-

G25CL60/SB

Clear Silver Bowl

10/100

130

-

3500

C-9

4.50”

-

5006

G25WH60

White

10/100

130

480

3500

C-9

4.50”

-

Cand.

Cand.

Med.

G16.5 Cand.

G19.5 Med.
G25

X,N,2

CTC60

2

Med.

C11

2

Med.

5005
102382

®

G30

Med.

5506

G30WH60

White

10/100

130

480

5000

C-9

5.00”

-

G40

Med.

5205

G40CL60

Clear

6/24

130

520

5000

C-9

6.93”

-

5204

G40WH60

White

6/24

130

450

5000

C-9

6.93”

-

5007

G25CL100

Clear

10/100

130

1100

3500

C-9

4.50”

-

5207

G40CL100

Clear

6/24

130

1100

5000

C-9

6.93”

-

5206

G40WH100

White

6/24

130

950

5000

C-9

6.93”

-

100 WATT
G25

Med.

G40

Med.

E Means this lamp meets Federal Minimum Efficiency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 149

INCANDESCENT LAMPS

Bulb, Base and Filament Identification Guide
Bulb Shapes

A
A-Shape

CA5
Candelabra
Base

BR
Bulge Neck
Reflector

G
Globe
Candelabra

C
Cylindrical

G
Globe
Medium

CA8-CA10
Candelabra
Base

B8-B10
Candelabra
Base

PAR36
Parabolic
Reflector

CA8-CA10
Edison
Base

PAR
Parabolic
Reflector

ER
Elliptical
Reflector

PS
Pear
Straight
Neck

B8-B10
Edison
Base

R
Reflector

F
Flame

S
Straight
Side

T
Tubular

Base Types

Screw
Terminals

Intermediate
E17

DC
Bayonet
BA15d

Medium
E26

Candelabra
E12

Medium
Side Prong

E14

Mog.
E39

Mog. End
Prong

Filament Designations

CC-2V

C3-A

C-5

CC-6

C-7A

CC-8

CC-9

C-9M

CC-13

CC indicates coiled-coil filament.

150

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

INCANDESCENT LAMPS
Symbols, Footnotes and Abbreviations
SYMBOLS
 New product introduced within the past year.
Al Aluminum base.
N Nickel-plated brass base.
r Heat-resistant glass.
$ Energy saving product.
E

This lamp meets Federal Minimum Efficiency standards.

X Product will be discontinued when inventory is depleted.
L Legislated lamp will not be manufactured after January 1, 2014.

FOOTNOTES
1 Operate base down.
2 Operate base down to horizontal.
3 Operate base up.
4 This lamp should be shielded from moisture to prevent breakage.
5 May not give satisfactory performance if accessory equipment is attached to or touches bulb.
6

Do not allow hot bulb to come in contact with liquid or metal parts of the fixture, as glass may shatter.
Do not use outdoors or operate near flammable materials. Operate in heat-resistant sockets.

7 Do not use in equipment where base temperature will exceed 500°F.
8 Use only in equipment specially designed to maintain bulb and base temperatures within safe limits.
9 May be used for indoor and outdoor applications.
10 Use only in circuits supplying the voltage indicated on the lamp. Not for use in household sockets.
CAUTION: Do not operate near flammable material. Operate only in heat-resistant sockets.
WARNING: Use with care. May cause serious burns. The unattended use of infrared heat by children
11 or incapacitated persons is dangerous. Do not place closer than 18” to surface area. Do not use for
therapeutic applications unless recommended by a physician. For food warming, use only lamps with
heat-resistant glass and/or heat-resistant coating.
12

Although this bulb is made of heat-resistant glass, it may break if moisture falls on it.
Not recommended for use in enclosed and/or close-fitting housing.

13 Use only with heat-resistant connector and with lamp supported by bulb rim.
14 Operate only in porcelain sockets.
15

Unsatisfactory operation if operated in positions between horizontal and base up, particularly between
45° from base up and base down.

16 Do not operate in aviaries or around fowl or small animals.
17 See Halogen footnotes 1, 2 and 7 on page 131.
18 See Halogen footnotes 1, 7 and 8 on page 131.
19 See Halogen footnotes 1 and 7 on page 131.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 151

INCANDESCENT LAMPS
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
/1 Suffix used to indicate a Clear Faceted Infrared lamp.
3W Code abbreviation for Three Way lamps.
/5 Suffix used to indicate 5,000 hour lamps.
/10 Suffix used to indicate Red-Faced Heat lamps.
/12V Suffix used to indicate 12 Volt lamps.
/20 Suffix used to indicate Prism UltraLife 20,000 hour lamps.
®

®

/39 Suffix used to indicate 39 Watt HaloXen PAR lamps.
®

/120 Suffix used to indicate 120 Volt lamps.
/130 Suffix used to indicate 130 Volt HaloXen PAR lamps.
®

/145V Suffix used to indicate 145 Volt lamps.
/1750 Suffix used to indicate lamps that produce 1750 lumens.
/CAN Suffix used to indicate lamps with Candelabra (E12) base.
/E12 Suffix used to indicate lamps with an E12 (candleabra) base.
/E14 Suffix used to indicate lamps with an E14 base.
/E17 Suffix used to indicate lamps with an E17 (intermediate) base.
/E26 Suffix used to indicate lamps with an E26 (medium) base.
AMB Code abbreviation for lamps with an Amber finish.
BG Code abbreviation for Bug Light lamps.
BLU Code abbreviation for lamps with a Blue finish.
C Code abbreviation for lamps with a Ceramic color finish.
CL Code abbreviation for lamps with a Clear finish.
/CS Suffix used to indicate CoverShield safety coated lamps.
®

/CSTF Suffix used to indicate CoverShield PFA safety coated lamps.
®

DC Code abbreviation for lamps with a Double Contact Bayonet base (BA15d).
DPNK Code abbreviation for lamps with a Dawn Pink finish.
FL Code abbreviation for Flood lamps.
FR Code abbreviation for lamps with a Frost finish.
GRN Code abbreviation for lamps with a Green finish.
GRO Code abbreviation for Plant Grow lamps.
/HG Suffix used to indicate Hard Glass lamps.
HP Code abbreviation for Halogen PAR lamps.

152

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

INCANDESCENT LAMPS
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
/HX Suffix used to indicate HaloXen lamps.
®

INT Code abbreviation for lamps with an Intermediate (E17) base.
L Code abbreviation for Long Neck Halogen PAR30 lamps.
/M Suffix used to indicate Major brand lamps (GE, Philips, Osram/Sylvania).
MED Code abbreviation for lamps with a Medium (E26/27) base.
MFL Code abbreviation for Medium Flood lamps.
N Code abbreviation for High-Intensity lamps.
/ND Suffix used to indicate PureLite Natural Daylight lamps.
®

NFL Code abbreviation for Narrow Flood lamps.
/NL Suffix used to indicate Night Light.
NSP Code abbreviation for Narrow Spot lamps.
ORG Code abbreviation for lamps with an Orange finish.
/P5 Suffix used to indicate Prism Long Life Plus 5,000 Hour staggered support C-9M filament lamps.
®

®

/P10 Suffix used to indicate Prism Ultra Life 10,000 Hour staggered support C-9M filament lamps.
®

®

PNK Code abbreviation for lamps with a Pink finish.
PUR Code abbreviation for lamps with a Purple finish.
Q Code abbreviation for Quartz Halogen lamps.
RED Code abbreviation for lamps with a Red finish.
RS Code abbreviation for Rough Service lamps.
/S Code abbreviation for HaloXen Silver PAR lamps.
®

/SB Suffix used to indicate Silver Bowl.
SG Code abbreviation for Spun Glow decorative lamps.
SP Code abbreviation for Spot lamps.
SW Code abbreviation for lamps with a Soft White finish.
/T Suffix used for colored Incandescent lamps with a Transparent finish.
VNSP Code abbreviation for Very Narrow Spot lamps.
VWFL Code abbreviation for Very Wide Flood lamps.
WFL Code abbreviation for Wide Flood lamps.
WH Code abbreviation for lamps with a White finish.
XIR Suffix used to indicate Halogen Infrared lamps.
YEL Code abbreviation for lamps with a Yellow finish.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 153

®

SPECIALTY LAMPS
CONTENTS
156 How to Read a Table
157 Safety Coated Metal Halide Lamps
157 Safety Coated Incandescent Lamps
157 Safety Coated Halogen Lamps
158 Safety Coated Compact Fluorescent Lamps
158 Safety Coated Linear Fluorescent Lamps
159 Photo/Projection/SSTV Lamps
161 Miniature Lamps
164 Sealed Beam Lamps
165 Accessories
166 Bulb, Base and Filament Identification
167 Symbols, Footnotes and Abbreviation

main
TOC

HOW TO READ A SPECIALTY LAMP TABLE
PACKAGE QUANTITY
FOOTNOTES &
SYMBOLS

BULB

Base

Watts

Product
Number

Footnotes

Average rated
life expressed
in hours.

A term used to
describe the
color of a light
source and is
expressed in
degrees
“Kelvin” (K).

Abbreviated product
description can also
be used for ordering.
A key to abbreviations
can be found on
page 168.

Use this product
number when
placing an order.

AVERAGE
LIFE

COLOR
TEMP.

PRODUCT
CODE

PRODUCT
NUMBER

Bulb

Bulb finish and other
important information.

Related footnotes can
be found on page 167.

Designations indicate shape
and size. Illustrations can
be found on page 166 and
at the top of each page.

Indicates minimum sell quantity
and smallest shipping carton.

DESCRIPTION

MOL

Indicates
maximum
overall
length in
inches.

Product
Code

Description

Pkg.
Qty.

ANSI

Color
Temp.

Lumens

Avg.
Life

MOL

Metal Halide
ED28

Mog.

250

108604

6,9,12,13,14,15

MH250/U/CSTF

Clear PFA

1/12

M58/E

4000

21800

10000

8.25”

ED37

Mog.

400

108600

6,8,9,12,13,14,15

MH400/U/CSTF

Clear PFA

1/6

M59/E

4000

36000

20000

11.50”

EX39

400

60502

MP400/BU/CSTF

Clear Base Up PFA

1/6

M59/O

4000

36000

20000

11.50”

ANSI
Code

Bulb

®

7,8,9,10,11,15
Base

Watts

Volts

Pkg.
Qty.

Avg.
Life

Filament

Lumens

Color
Temp.

Operating
Position

Photo/Projection/SSTV

ETH

Frosted/T4

E11

150

120

1/10

2000

CC-8

2700

2900

U

*EVW

MR16

GY5.3

250

82

1/10

50

CC-8

-

3300

BDTH

*EXR

MR13

GX5.3

300

82

1/10

35

CC-8

-

3350

BDTH

FILAMENT

Filament types
are illustrated
on page 166.

ANSI
CODE

The specific
electrical
characteristics
of a lamp.

BASE

Indicates base type.
Full base descriptions
and illustrations can be
found on page 166.

VOLTS

OPERATING
POSITION

Indicates the
product’s design
voltage of operation.

LUMENS

Indicates the
approved
operating positon
of a lamp.

The lamp’s average
light output at 40%
of rated life.

TOC

SPECIALTY LAMPS
Safety Coated

ED28

Bulb

Base

A15
A19
A21

ED37

Watts

Product
Number

BR30
BR40

B10

Footnotes

R12
R20

PS

R40

T10

ALR

Product
Code

Description

Pkg.
Qty.

ANSI

Color
Temp.

Lumens

Avg.
Life

MOL

1/12

M58/E

4000

21800

10000

8.25”

Metal Halide
ED28 Mog.

250

108604

6,9,12,13,14,15

MH250/U/CSTF

Clear PFA

ED37 Mog.

400

108600

6,8,9,12,13,14,15

MH400/U/CSTF

Clear PFA

1/6

M59/E

4000

36000

20000

11.50”

EX39

400

60502

MP400/BU/CSTF

Clear Base Up PFA

1/6

M59/O

4000

36000

20000

11.50”

Bulb

Base

Watts

7,8,9,10,11,15

Product
Number

Footnotes

Product
Code

Description

Pkg.
Qty.

Lumens

Avg.
Life

MOL

Incandescent
A15

A19

Med.

Med.

A21

Med.

B10

Med.

40

90300

A15CL40/CSTF

Clear PFA

20/120

300

3000

3.50”

40

6146

A15RS40/CS

Clear

20/120

300

1500

3.50”

60

6147

A15RS60/CS

Clear

20/120

500

1500

3.50”

25

101124

A19RS25/CS

Clear

20/120

160

2000

4.25”

40

101125

A19RS40/CS

Clear

20/120

300

2000

4.25”

60

6141

A19RS60/CS

Clear

20/120

500

2500

4.25”

75

6142

A19RS75/CS

Clear

20/120

680

2000

4.25”

100

6143

A19RS100/CS

Clear

20/120

960

2500

4.25”

100

6041

A21RS100/P5/CS

Clear

12/60

800

5000

5.00”

150

6043

A21RS150/P5/CS

Clear

1/60

1300

5000

5.00”

40

102148

16

ETC40/CS

Clear

25/500

370

3000

3.87”

60

102146

16

ETC60/CS

Clear

25/500

650

3000

3.87”

BR30

Med.

65

404051

18

BR30FL65/CS

Flood

1/24

580

5000

5.37”

BR40

Med.

120

404065

18

BR40FL120/5/CS

Flood

1/24

1200

5000

6.56”

125

90320

BR40CL125/1/CSTF

Clear Heat PFA

1/12

-

6000

6.56”

250

404066

18,20,22

BR40CL250/1/CSTF

Clear Heat PFA

1/12

-

5000

6.56”

150

401345

17

PS25CL150/P5/CS

Clear

1/60

1300

5000

6.93”

17

PS25

Med.

200

401347

PS25CL200/P5/CS

Clear

1/60

2000

5000

6.93”

R12

BA15s

20

1383/CS

1383/CS

S.C. Bayonet 13V

10/1000

-

300

2.60”

R20

Med.

30

10102

R20FL30/CS

Flood

10/100

140

3000

3.93”

50

104016

R20FL50/CS

Flood

10/100

210

2000

4.80”

250

404071

18,20,21

R40RED250/10/CSTF

Red Heat PFA

1/12

-

5000

6.56”

375

104050

15,18,19,20,21

R40CL375/CSTF

Clear Heat PFA

1/12

-

5000

6.56”

40

106228

T10CL40/CS

Clear

25/200

280

2500

5.00”

GBF/CS

Flood Frosted 12V

1/50

750cp

2000

1.46”

R40

T10

Med.

Med.

Halogen
ALR

BA15d

20

90351

Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 157

Specialty LAMPS
Safety Coated
T5
Miniature Bi-Pin

®

R30

Bulb

Base

Watts

Product
Number

Footnotes

Product
Code

Description

T8/T12
Medium Bi-Pin

Pkg.
Qty.

ANSI

Color
Temp.

Lumens

Avg.
Life

MOL

6/24

5000

82

750

8000

5.56”

Compact Fluorescent
R30

Med.

16

46106

X 1,2,4

CFL16/50/R30/CS

Natural White Flood

Linear Fluorescent
T5

T8

Min.
Bi-Pin

Med.
Bi-Pin

28

90015

X

E

4,5

F28T5/835/ECO/IC/CS

835 Phosphor

25

3500

86

2900

24000

46”

28

90016

X

E

4,5

F28T5/841/ECO/IC/CS

841 Phosphor

25

4100

86

2900

24000

46”

54

90051

E

4,5

F54T5/835/HO/ECO/IC/CS

835 Phosphor High Output

25

3500

86

5000

24000

46”

54

90052

E

4,5

F54T5/841/HO/ECO/IC/CS

841 Phosphor High Output

25

4100

86

5000

24000

46”

54

90053

E

4,5

F54T5/850/HO/ECO/IC/CS

850 Phosphor High Output

25

5000

86

5000

24000

46”

28

90081

32

E

4

F28T8/835/ECO/IC/CS

835 Phosphor

25

3500

86

2800

24000

48”

90084

E

4

F32T8/735/ECO/CS

735 Phosphor

25

3500

78

2850

24000

48”

32

90085

E

4

F32T8/741/ECO/CS

741 Phosphor

25

4100

78

2850

24000

48”

32

90089

E

4

F32T8/750/ECO/CS

750 Phosphor

25

5000

78

2850

24000

48”

32

90094

E

4

F32T8/835/ECO/CS

835 Phosphor

25

3500

86

3050

24000

48”

32

90095

E

4

F32T8/841/ECO/CS

841 Phosphor

25

4100

86

3050

24000

48”

32

90096

E

4

F32T8/850/ECO/CS

850 Phosphor

25

5000

86

3050

24000

48”

X

Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.

158

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Specialty LAMPS
Photo/Projection/SSTV
PAR36

ANSI
Code

T7

T4
BA15d

T4.25

Bulb

®

T4
E11

Base

MR16
GY5.3

Watts

G7

T3

Volts

Pkg.
Qty.

Avg.
Life

Filament

Lumens

Color
Temp.

Operating
Position

Photo/Projection/SSTV

DVS

T3

R7s

500

130

1/10

2000

C-8

9500

3000

HOR

*DWE

PAR36

Screw Terminals

650

120

1/12

100

C-6

24000

3200

U

*DYS/DYV/BHC/5

G7

GZ9.5

600

125

1/10

150

CC-6

17000

3200

HOR

*EGE

T4.25

P28s

500

120

1/10

2000

CC-8

10450

2950

U

EHM

T3

R7s

300

120

1/10

2000

C-8

5000

2950

HOR

EHT

T4

E11

250

120

1/10

2000

CC-8

4500

2950

U

*EHV

T4

E11

325

120

1/10

500

CC-8

7800

3000

U

EJA

MR16

GX5.3

150

21

1/10

40

CC-6

-

3400

BDTH

*EJL

MR16

GX5.3

200

24

1/10

50

CC-6

-

3400

BDTH

*EJM

MR16

GX5.3

150

21

1/10

40

CC-6

-

3350

BDTH

EJV

MR16

GX5.3

150

21

1/10

40

CC-8

-

3350

BDTH

EKE

MR16

GX5.3

150

21

1/10

200

CC-6

-

3250

BDTH

ELC

MR16

GX5.3

250

24

1/10

50

CC-6

-

3400

BDTH

*ENH

MR16

GY5.3

250

120

1/10

175

CC-8

-

3250

BDTH

*ENX

MR16

GY5.3

360

82

1/10

75

CC-8

-

3300

BDTH

*ENX/5

MR16

GY5.3

360

86

1/10

100

CC-8

-

3300

BDTH

*ESD

MR16

GY5.3

150

120

1/10

12

CC-8

-

3350

BDTH

*ESL

T4

E11

150

120

1/10

1000

CC-2V

2800

2900

U

*ESM

Frosted/T4

E11

250

120

1/10

2000

CC-8

4850

2950

U

*ESN

T4

E11

100

120

1/10

750

CC-2V

1900

2850

U

*ESP

T4

BA15d

150

120

1/10

1000

CC-2V

2400

2950

U

*ESR

T4

BA15d

100

120

1/10

1000

CC-2V

1900

3000

U

*ESS

T4

BA15d

250

120

1/10

2000

CC-8

5000

3000

U

*ETB

Frosted/T4

BA15d

250

120

1/10

2000

CC-8

4700

2950

U

ETC

T4

BA15d

150

20

1/10

2000

CC-8

2800

2900

U

*ETD

Frosted/T4

BA15d

100

120

1/10

750

CC-2V

1750

2900

U

*ETE

Frosted/T4

E11

100

120

1/10

750

CC-2V

1750

2900

U

ETF

Frosted/T4

BA15d

150

120

1/10

2000

CC-8

2700

2900

U

*ETG

T4

E11

150

120

1/10

2000

CC-8

2400

2950

U

* Item will be discontinued when inventory is depleted.

Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 159

SPECIALTY LAMPS
Photo/Projection/SSTV
T3

ANSI
Code

Bulb

®

Base

Watts

PAR36

T4
E11

T3.5

MR16
MR13
GY5.3

T6
G9.5

ALR

Volts

Pkg.
Qty.

Avg.
Life

Filament

Lumens

Color
Temp.

Operating
Position

Photo/Projection/SSTV continued

ETH

Frosted/T4

E11

150

120

1/10

2000

CC-8

2700

2900

U

*EVW

MR16

GY5.3

250

82

1/10

50

CC-8

-

3300

BDTH

*EXR

MR13

GX5.3

300

82

1/10

35

CC-8

-

3350

BDTH

*EXR/5

MR13

GX5.3

300

86

1/10

70

CC-8

-

3350

BDTH

*EXY

MR13

GX5.3

250

82

1/10

200

CC-8

-

3200

BDTH

*EYA

MR16

GY5.3

200

82

1/10

50

CC-8

-

3300

BDTH

*EYB

T3.5

G5.3

360

82

1/10

75

CC-8

10000

3300

BDTH

*EYB/5

T3.5

G5.3

360

86

1/10

150

CC-8

10000

3300

BDTH

EYV

Frosted/T4

E11

500

130

1/10

2000

CC-8

8075

3000

U

EYW

T4

E11

500

130

1/10

2000

CC-8

8500

3000

U

*FAL

T4

R7s

420

120

1/10

90

CC-8

11000

3200

U

*FBO

PAR36

Screw Terminals

650

120

1/12

100

C-6

38000

3400

U

*FCL

T3

R7s

500

120

1/10

2000

C-8

9500

3000

HOR

*FCM

T3

R7s

1000

120

1/10

300

C-8

27000

3200

HOR

*FCR

T3.5

GY6.35

100

12

1/10

50

C-6F

2900

3250

BDTH

FCS

T4

G6.35

150

24

1/10

50

C-6F

4500

3400

ANY

*FEL

T6

G9.5

1000

120

1/10

300

CC-8

27000

3200

BDTH

*FHM

Frosted/T3

R7s

1000

120

1/10

300

C-8

26000

3200

HOR

*FHS

MR13

GX5.3

300

82

1/10

70

CC-8

-

3300

BDTH

*FHS/5

MR13

GX5.3

300

86

1/10

140

CC-8

-

3300

BDTH

FLK

T6

G9.5

575

115

1/10

300

CC-8

16000

3200

U

*GBE

ALR12

BA15d

20

12

1/10

2000

CC-8

1500cp

3000

U

GBF

ALR12

BA15d

20

12

1/10

2000

CC-8

750cp

3000

U

GBF/CS

ALR12

BA15d

20

12

1/10

2000

CC-8

750cp

3000

U

H111

MR16

GX5.3

200

19.7

1/100

500

CC-8

-

3000

BDTH

* Item will be discontinued when inventory is depleted.

Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.

160

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Specialty LAMPS
Miniatures
T1.75
S.C. Midget
Flanged

Product
Code

Bulb

T2.5
BA9s

T3.25
T5
Wedge

T3.25
BA9s

Base

Primary
Application

Volts

Amps or
Watts

Pkg.
Qty.

MSCP

Avg.
Life

Design
Filament

MOL

Miniatures
55

G4.5

BA9s

Indicator

7

0.41

10/2000

2

500

C-2R

1.07”

*57

G4.5

BA9s

Auto, Instrument

14

0.24

10/2000

2

500

C-2V

1.07”

73

T1.75

Wedge

Indicator

14

0.08

10/2000

0.3

15000

C-2V

0.80”

*74

T1.75

Wedge

Auto

14

0.10

10/2000

0.7

1000

C-2V

0.80”

85

T1.75

Wedge

Indicator

28

0.04

10/2000

0.3

7000

C-2F

0.80”

*86

T1.75

Wedge

Indicator

6.3

0.20

10/2000

0.4

20000

C-2V

0.80”

*89

G6

BA15s

Auto

13

0.58

10/2000

6

750

C-2R

1.40”

93

S8

BA15s

Auto

12.8

1.04

10/2000

15

700

C-6

2.00”

94

S8

BA15d

Auto, Marine

12.8

1.04

10/2000

15

700

C-6

2.00”

120MB/M

T2.5

BA9s

Tel. Indicator

120

0.025

10/100

0.36

10000

CC-3A

1.20”

130MB

T2.5

BA9s

Indicator

130

0.025

10/2000

0.36

10000

CC-3A

1.19”

*159

T3.25

Wedge

Indicator

6.3

0.15

10/2000

0.34

5000

C-2R

1.06”

161

T3.25

Wedge

Auto, Instrument

14

0.19

10/2000

1

4000

C-2F

1.06”

194

T3.25

Wedge

Auto

14

0.27

10/2000

2

2500

C-2F

1.10”

*259

T3.25

Wedge

Radio

6.3

0.25

10/2000

0.65

5000

C-2R

1.06”

*313

T3.25

BA9s

Aircraft

28

0.17

10/2000

3.5

500

C-2F

1.19”

*316

T3.25

BA9s

Aircraft

6

0.70

10/2000

3.4

500

C-2R

1.19”

*400

T3.25

Wedge

Aircraft

28

0.10

10/2000

1.6

1000

C-2F

1.06”

*456

G4.5

BA9s

Instrument

28

0.17

10/2000

2

5000

C-2F

1.07”

464

T3.25

Wedge

Aircraft

28

0.17

10/2000

3

1500

C-2F

1.06”

555

T3.25

Wedge

Pinball

6.3

0.25

10/2000

0.9

3000

C-2R

1.06”

590

T3.25

Wedge

Strip Lighting

13.5

0.37

10/2000

4

300

C-2V

1.06”

656

T3.25

Wedge

Indicator

28

0.06

10/2000

0.62

2500

C-2F

1.06”

657

T3.25

Wedge

Indicator

28

0.08

10/2000

0.62

15000

C-2F

1.06”

658

T3.25

Wedge

Indicator

14

0.08

10/2000

0.31

15000

C-2F

1.06”

755

T3.25

BA9s

Indicator

6.3

0.15

10/2000

0.33

20000

C-2R

1.20”

756

T3.25

BA9s

Indicator

14

0.08

10/2000

0.31

15000

C-2F

1.19”

757

T3.25

BA9s

Indicator

28

0.08

10/2000

0.62

15000

C-2F

1.19”

904

T5

Wedge

Auto

13.5

0.69

10/2000

4

5000

C-2F

1.50”

906

T5

Wedge

Auto

13.0

0.69

10/2000

6

1000

C-2F

1.50”

909

T5

Wedge

Emergency Lighting

6.0

0.62

10/2000

3

50

C-2R

1.50”

912

T5

Wedge

Auto

12.8

1.00

10/2000

12

1000

C-2R

1.50”

* Item will be discontinued when inventory is depleted.

Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 161

Specialty LAMPS
Miniatures
R12

Product
Code

Bulb

Base

T5
Wedge

RP11
BA15s

Primary
Application

Volts

T3.25

Amps or
Watts

T1.75

Pkg.
Qty.

T2

S8
BA15d

T2.5

MSCP

Avg.
Life

Design
Filament

MOL

Miniatures continued
912x Xenon

T3.25

Wedge

Garden

12.8

1.00

10/600

12

10000

C-2R

1.50”

918

T5

Wedge

Garden

12.8

0.56

10/2000

6.5

500

C-2R

1.50”

918x Xenon

T3.25

Wedge

Garden

12.8

0.56

10/600

6.5

10000

C-2R

1.50”

921

T5

Wedge

Auto

12.8

1.40

10/2000

21

500

C-2R

1.50”

921x Xenon

T3.25

Wedge

Auto

12.8

1.4

10/600

21

10000

C-2R

1.50”

1141

S8

BA15s

Auto

12.8

1.44

10/2000

21

1000

C-6

2.00”

1142

S8

BA15d

Auto

12.8

1.44

10/2000

21

1000

C-6

2.00”

1156

S8

BA15s

Auto, Stop

12.8

2.10

10/2000

32

1200

C-6

2.00”

1195

RP11

BA15s

Auto

12.5

3.00

10/500

50

300

C-2V

2.30”

*1196

RP11

BA15d

Auto

12.5

3

10/500

50

300

C-2R

2.25”

*1229

S8

BA15d

Emergency Lighting

40

0.38

10/1000

15

400

C-2V

2.00”

*1317

B6

BA15s

Aircraft, Emergency

6

0.51

10/1000

3.4

100

C-6

1.75”

1383

R12

BA15s

Aircraft, Reading

13

20

10/1000

-

300

C-8

2.60”

1383/CS

R12

BA15s

Aircraft, Reading

13

20

10/1000

-

-

C-8

2.60”

*1460X

S8

D.C. Pre-Focus

Microscope

6.5

2.75

10/500

23

100

C-6

2.00”

*1493

S8

BA15d

Microscope

6.5

2.75

10/1000

23

100

C-6

2.00”

*1495

T4.5

BA9s

Aircraft

28

0.30

10/1000

6

500

C-2F

1.38”

*1591

S8

BA15s

Aircraft

25

0.61

10/1000

15

1000

C-2V

2.00”

1612

S8

BA15d

Instrument

5.4

1.9

10/1000

10

1000

C-6

2.00”

*1619

S8

BA15s

Instrument

6.7

1.90

10/1000

15

500

C-6

2.00”

1630

S8

D.C. Pre-Focus

Instrument

6.5

2.75

10/500

23

100

C-6

2.00”

*1638

S8

BA15d

Marine

28

1.02

10/1000

32

500

2C-6

2.00”

*1680

S8

BA15s

Aircraft

6

4.10

10/1000

32

300

C-6

2.00”

*1680X

S8

BA15s

Aircraft

6

4.10

10/1000

32

300

C-6

2.00”

*1691AF

S8

BA15s

Aircraft, Frosted

28

0.61

10/1000

-

1000

2C-2R

2.00”

*1777

S8

BA15s

Aircraft

12.8

1.52

10/1000

26

400

C-2R

2.00”

*1813

T3.25

BA9s

Radio

14.4

0.10

10/2000

0.86

1000

C-2V

1.20”

1818

T3.25

BA9s

Aircraft

24

0.17

10/2000

3.3

250

C-2F

1.20”

1819

T3.25

BA9s

Indicator

28

0.04

10/2000

0.34

2500

C-2F

1.20”

1820

T3.25

BA9s

Indicator

28

0.10

10/2000

1.6

1000

C-2F

1.20”

*1822

T3.25

BA9s

Inidcator

36

0.10

10/2000

2.1

1000

C-2F

1.20”

*1828

T3.25

BA9s

Indicator

37.5

0.05

10/2000

0.65

3000

C-2F

1.20”

* Item will be discontinued when inventory is depleted.

Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.

162

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Specialty LAMPS
Miniatures
S8
Wedge

Product
Code

T3.25

Bulb

S11

Base

S8
BA15s

Primary
Application

Volts

Amps or
Watts

Pkg.
Qty.

MSCP

Avg.
Life

Design
Filament

MOL

Miniatures continued
1829

T3.25

BA9s

Indicator

28

0.07

10/2000

1

1000

C-2F

1.20”

1835

T3.25

BA9s

Indicator

55

0.05

10/2000

1.1

5000

C-2F

1.20”

*1864

T3.25

BA9s

Aircraft

28

0.17

10/2000

3

1500

C-2F

1.20”

*1866

T3.25

BA9s

Radio

6.3

0.25

10/2000

0.65

5000

C-2R

1.20”

*2232

S8

BA15s

Aircraft

28

0.64

10/1000

18

2000

CC-8

2.00”

*2233

S8

BA15s

Aircraft

28

0.77

10/1000

21

2000

CC-8

2.00”

*3011

S11

BA15s

Aircraft

28

1.29

10/500

44

1000

C-2V

2.38”

3156

S8

Plastic Wedge

Auto, Stop

12.8

2.10

10/2000

32

1200

C-6

2.10”

3155K

S8

Plastic Wedge

Auto, Signal

12.8

1.60

10/2000

21

5000

C-6

2.10”

3156K

S8

Plastic Wedge

Auto, Stop

12.8

2.10

10/2000

32

5000

C-6

2.10”

*18S11/1SC

S11

BA15s

Railway Signal

10

18W

10/500

360lm

2000

CC-6

2.37”

*25S11/4SC

S11

BA15s

Railway Signal

10

25W

10/500

200lm

1000

CC-6

2.37”

* Item will be discontinued when inventory is depleted.

Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 163

Specialty LAMPS
Sealed Beam

PAR46/56/64

PAR36

Product
Code

Bulb

Base

Volts

Watts

Pkg.
Qty.

CBCP

Avg.
Life

Design
Filament

Beam
Spread

MOL

Sealed Beam
*4405

PAR36

Screw Terminals

12.8

30

1/12

50000

100

C-6

6

2.75”

4406

PAR36

Screw Terminals

12.8

35

1/12

600

300

C-6

80

2.75”

4411

PAR36

Screw Terminals

12.8

35

1/12

3000

300

C-6

-

2.75”

4414

PAR36

Screw Terminals

12.8

18

1/12

1500

300

C-6

50

2.75”

4415

PAR36

Screw Terminals

12.8

35

1/12

9000

300

C-6

40

2.75”

4446

PAR36

Screw Terminals

12.8

25

1/12

400

300

C-6

80

2.75”

4505

PAR36

Screw Terminals

28

50

1/12

45000

400

C-6

5

2.75”

*4509

PAR36

Screw Terminals

13

100

1/12

110000

25

C-6

12x6

2.75”

4515

PAR36

Screw Terminals

6.4

30

1/12

55000

100

C-6

7x6

2.75”

H4515

PAR36

Screw Terminals

6.4

30

1/12

65000

100

C-6

7x6

2.75”

*4535

PAR46

Screw Terminals

6.4

30

1/12

95000

100

C-6

5.5

4.00”

4545

PAR56

Screw Terminals

12

100

1/12

225000

100

C-6

9

5.00”

*4552

PAR64

Screw Terminals

28

250

1/6

500000

25

CC-8

7x8

6.00”

*4553

PAR46

Screw Terminals

28

250

1/12

300000

25

CC-8

11x12

4.00”

*4559

PAR64

Screw Terminals

28

600

1/6

600000

25

C-6

11x12

6.00”

*4587

PAR36

Screw Terminals

28

250

1/12

40000

25

CC-8

40

2.75”

*4596

PAR36

Screw Terminals

28

250

1/12

150000

25

CC-8

11x12

2.75”

7613

PAR36

Screw Terminals

6

8

1/12

400

50

C-6

30

2.75”

7613-1

PAR36

Slip-on Terminals

6

8

1/6

400

50

C-6

30

2.75”

* Item will be discontinued when inventory is depleted.

Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.

164

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Specialty LAMPS
Accessories

Product
Number

Product
Code

Description

Terminal

Pkg.
Qty.

Lead Length

91020

TG32T8CL

4’ T8 Clear Tube Guard with Endcap

-

48

-

91021

TG40T12CL

4’ T12 Clear Tube Guard with Endcap

-

24

-

91022

TG96T8CL

8’ T8 Clear Tube Guard with Endcap

-

48

-

91023

TG96T12CL

8’ T12 Clear Tube Guard with Endcap

-

24

91001

ADP/E26/GU24

Locking Adapter E26 to GU24

-

1/200

-

91002

ADP/E39/E26

Porcelain Adapter E39 to E26

-

1/200

-

ADP/E26/E26

Porcelain Extender E26

-

1/200

-

Tube Guards

Adapters

Extenders
91000

Sockets
91010

SKT/E39/4KV

Mog. Base Porcelain Pulse Rated HID Socket 4KV

Screw

1/100

10”

91011

SKT/E26/4KV

Medium Base Porcelain Pulse Rated HID Socket 4KV

Screw

25/200

18”

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 165

SPECIALTY LAMPS
Bulb, Base and Filament Identification Guide
Bulb Shapes

ALR

S8
BA15d

G6

G7

S8
BA15s

PAR36

T1.75

T2

T2.5

PAR64

T3

T3.25

PAR46/56/64

T4
E11

T3.25/T5

MR16

T4

RP11

T4.25

T5/T6

R12

T6

T7

Base Types

E11
Mini-Can

E12

G5.3/GX5.3

SC Midget
Flanged

E17

G9.5/GZ9.5

SC Miniature
Bayonet BA9s

E26
Medium

P28s
Medium
Prefocus

Screw
Terminals

R7s

Slip
Terminals

Slide #5

G4

G6.35

SC Bayonet
BA15s

DC Bayonet
BA15d

Plastic
Wedge

Wedge

Filament Designations

C-2F

C-2R

C-2V
CC-2V

C-6
CC-6

CC-7A

C-8
CC-8

CC indicates coiled-coil filament.
166

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Specialty LAMPS
Symbols, Footnotes and Abbreviations
SYMBOLS
E

This lamp meets Federal Minimum Efficiency standards.
ProLume Eco-Shield Low-Mercury Fluorescent lamps pass the Federal TCLP for hazardous wastes.
®

®

X Product will be discontinued when inventory is depleted.

FOOTNOTES
Indoor use only. Outdoor use requires weather-protected fixture. All self-ballasted lamps meet part 18 of the FCC rules.
1 These products may cause interference with AM radios, cordless telephones and remote control devices. If interference
continues, move the lamp away from the device or plug into a different outlet.
ProLume lamps with an integrated electronic ballast designed for 120-volt operation. Lamps operated at a higher voltage
or in recessed or enclosed fixtures will have reduced life. Do not use with dimmers. Before using with photocell or
2
electronic timing devices, check device for compatibility with compact fluorescent lamps. Use with incompatible devices
will result in premature lamp failure. These products are UL listed.
®

3

UL approved for totally enclosed fixtures with a maximum ballast case temperature of 90°C for GU24 base lamps, 75°C
for medium base lamps.

4

Average life under specified test conditions with lamps turned off and restarted every three hours.
Lamp life is longer if lamps are started less frequently.

5

Lamp designed for use with Programmed Start ballast. Lamp operates at 170mA.
Minimum starting temperature is -15°F, with peak operating temperature at 95°F.

6 Lamps classified as E-type are used ONLY in suitably enclosed luminaries. See lamp warning.
7

Lamps classified as O-type comply with ANSI standard C78.387 for containment testing and may be used in open
luminaries. See lamp warning.

8 20,000 average rated life based on 10hrs/start. 30,000 average rated life based on 120 hrs/start.
Color characteristics may vary somewhat from one lamp to another. Time should be allowed for lamp to stabilize in color
when it is turned on for the first time or if for any reason its operating position is changed. This may require several hours
9
of operation, with more than one start. Lamp color and output may change temporarily if the lamp is subjected to excess
vibration or shock. Lamp color characteristics may change after long accumulated operating time.
10 Use with 4000 Volt pulse-rated sockets only.
11 Performance may not be satisfactory unless operated within specified operating positions.
Requires ballast that is designed to operate all popular brands of metal halide lamps.
12 1000W types will operate from H36 conventional lag type ballast for Mercury Vapor lamps at ambient
temperatures of 50°F or higher. 1000W types must not be operated at 1500W or higher.
13 Rated average life: vertical ±15°. Other positions 75% of rated life.
14 In general, horizontal lumens will be 5-10% lower than the vertical lumen values.
15 Do not operate in aviaries or around fowl or small animals.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 167

Specialty LAMPS
Symbols, Footnotes and Abbreviations
FOOTNOTES
16 Operate base down to horizontal.
17 Operate base up.
18

Do not allow hot bulb to come in contact with liquid or metal parts of the fixture, as glass may shatter.
Do not use outdoors or operate near flammable materials. Operate in heat-resistant sockets.

19 Do not use in equipment where base temperature will exceed 500°F.
CAUTION: Do not operate near flammable material. Operate only in heat-resistant sockets.
WARNING: Use with care. May cause serious burns. The unattended use of infrared heat by children
20 or incapacitated persons is dangerous. Do not place closer than 18” to surface area. Do not use for
therapeutic applications unless recommended by a physician. For food warming, use only lamps with
heat-resistant glass and/or heat-resistant coating.
22 Operate only in porcelain sockets.

ABBREVIATIONS
/735 Suffix used to indicate lamps with CRI of 70+ and color temperature of 3500K.
/741 Suffix used to indicate lamps with CRI of 70+ and color temperature of 4100K.
/750 Suffix used to indicate lamps with CRI of 70+ and color temperature of 5000K.
/835 Suffix used to indicate lamps with CRI of 80+ and color temperature of 3500K.
/841 Suffix used to indicate lamps with CRI of 80+ and color temperature of 4100K.
/850 Suffix used to indicate lamps with CRI of 80+ and color temperature of 5000K.
/BA15s Suffix used to indicate lamps with a BA15s (Single Contact) base.
BU Code abbreviation for Base Up Operating lamps.
CL Code abbreviation for a Clear lamp.
/CS Suffix used to indicate CoverShield® safety coated lamps.
/CSTF Suffix used to indicate CoverShield® PFA safety coated lamps.
CW Code abbreviation for Cool White lamps.
DX Code abbreviation for Daylight lamps.
/ECO Suffix used to indicate Eco-Shield® TCLP compliant lamps.
/ES Suffix used to indicate Energy Saving Fluorescent lamps.
/FL Suffix used to indicate Flood lamps.
/HO Suffix used to indicate High Output lamps.
/IC Suffix used to indicate ProLume® Industrial/Commercial service lamps.
/P5 Suffix used to indicate Prism® Long Life Plus® 5,000 Hour staggered support C-9M filament lamps.
RED Code abbreviation for a Red Heat lamp.
U Code abbreviation for Universal Metal Halide lamps.
168

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

®

ELECTRONIC FLUORESCENT BALLASTS
CONTENTS
172 How to Read a Table
173 T5 Ballasts
178 T5 Circline Ballasts
180 T8 Ballasts
193 T9 Circline Ballasts
195 T12 Ballasts
200 Cross Reference Guide
201
202

main
TOC

HOW TO READ AN ELECTRONIC FLUORESCENT
BALLAST TABLE
PRODUCT CODE

INPUT
POWER

Lamp Type
Qty. Watts

Start
Type

WIRING
DIAGRAM

Total power
input to the
ballast which
includes lamp
watts and
ballast losses.

Voltage required
from a power
supply for
proper ballast
operation.

Specifies ballast
overall length,
mounting length,
width, and height.

Ratio of the lamp’s lumen
output on the specified
ballast to the lamp’s lumen
output when operated by a
reference ballast.

Abbreviated product description
can also be used for ordering.

INPUT
VOLTS

CASE
DIMENSIONS

BALLAST
FACTOR

References the
wiring diagram
to use.

Case Dimensions

Input
Volts

Product
Number

Product Code

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp.

Wire
Diag.

Case

Length Mounting Width Height

F28T5
1

28

PS

120

50166

EP228PS/MV

0.28

33

0.98

1.05

<10

0°F

1-10

J

16.90” 16.00”

1.20” 1.00”

28

PS

277

50166

EP228PS/MV

0.13

33

0.98

1.05

<10

0°F

1-24

J

16.90” 16.00”

1.20” 1.00”

28

PS

120

52112

EP228PS/MV/MC

0.29

31

0.98

1.05

<10

0°F

1-24

F

9.50”

8.90”

1.30” 1.10”

28

PS

277

52112

EP228PS/MV/MC

0.12

31

0.98

1.05

<10

0°F

1-10

F

9.50”

8.90”

1.30” 1.10”

THD%
LAMP TYPE

LINE
CURRENT

Indicates the type
of lamp that the
ballast will operate.

PRODUCT
NUMBER

Use this number when
placing an order.

TOC

The current that
results when the
line voltage is
applied to a load.

POWER
FACTOR

Watts to volt
amps ratio,
which measures
efficiency of a
ballast’s power
usage.

Indicates
percentage of
Total Harmonic
Distortion.

CASE

References the ballast’s
case shape.

MIN. START TEMP.

References minimum ambient
temperature that the ballast will
reliably start a lamp.

Electronic Fluorescent Ballasts
T5
Lamp Type

Case Dimensions

Input
Volts

Product
Number

Product Code

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

RS

120

50104

E114RS/120

0.23

14

0.53

1.00

<150

0°F

2-7

K

5.90”

5.60”

0.91” 0.76”

RS

120

50104

E114RS/120

0.25

16

0.53

0.95

<150

0°F

2-7

K

5.90”

5.60”

0.91” 0.76”

RS

120

50104

E114RS/120

0.22

14

0.53

0.95

<130

0°F

1-7

K

5.90”

5.60”

0.91” 0.76”

14

RS

120

50104

E114RS/120

0.23

15

0.54

0.95

<130

0°F

1-7

K

5.90”

5.60”

0.91” 0.76”

14

PS

120

52112

EP228PS/MV/MC

0.14

17

0.98

1.07

<10

0°F

1-24

F

9.50”

8.90”

1.30” 1.00”

14

PS

277

52112

EP228PS/MV/MC

0.07

17

0.98

1.07

<10

0°F

1-24

F

9.50”

8.90”

1.30” 1.00”

14

PS

120

52112

EP228PS/MV/MC

0.28

33

0.98

1.04

<10

0°F

2-9

F

9.50”

8.90”

1.30” 1.00”

14

PS

277

52112

EP228PS/MV/MC

0.13

33

0.98

1.04

<10

0°F

2-9

F

9.50”

8.90”

1.30” 1.00”

21

RS

120

50104

E114RS/120

0.30

21

0.57

0.80

<150

0°F

1-7

K

5.90”

5.60”

0.91” 0.76”

21

PS

120

52112

EP228PS/MV/MC

0.22

25

0.98

1.06

<10

0°F

1-24

F

9.50”

8.90”

1.30” 1.00”

21

PS

277

52112

EP228PS/MV/MC

0.10

25

0.98

1.06

<10

0°F

1-24

F

9.50”

8.90”

1.30” 1.00”

21

PS

120

52112

EP228PS/MV/MC

0.39

49

0.98

1.02

<10

0°F

2-9

F

9.50”

8.90”

1.30” 1.00”

21

PS

277

52112

EP228PS/MV/MC

0.17

49

0.98

1.02

<10

0°F

2-9

F

9.50”

8.90”

1.30” 1.10”

Start
Type

Qty. Watts

Length Mounting Width Height

F6T5
2

6

F8T5
2

8

F13T5
1

13

F14T5
1

2

F21T5
1

2

F24T5/HO
1
2

24

PS

120

50142

EP239HO/PS/MV

0.24

29

0.98

1.10

<12

0°F

1-10

J

16.90” 16.00”

1.20” 1.00”

24

PS

277

50142

EP239HO/PS/MV

0.12

29

0.98

1.12

<12

0°F

1-10

J

16.90” 16.00”

1.20” 1.00”

24

PS

120

50142

EP239HO/PS/MV

0.44

52

0.98

1.00

<12

0°F

2-8

J

16.90” 16.00”

1.20” 1.00”

24

PS

277

50142

EP239HO/PS/MV

0.20

52

0.98

1.00

<12

0°F

2-8

J

16.90” 16.00”

1.20” 1.00”

28

PS

120

52112

EP228PS/MV/MC

0.29

31

0.98

1.05

<10

0°F

1-24

F

9.50”

8.90”

1.30” 1.00”

28

PS

277

52112

EP228PS/MV/MC

0.12

31

0.98

1.05

<10

0°F

1-24

F

9.50”

8.90”

1.30” 1.00”

28

PS

120

52112

EP228PS/MV/MC

0.53

62

0.98

1.00

<10

0°F

2-9

F

9.50”

8.90”

1.30” 1.00”

28

PS

277

52112

EP228PS/MV/MC

0.23

61

0.98

1.00

<10

0°F

2-9

F

9.50”

8.90”

1.30” 1.10”

35

PS

120

52112

EP228PS/MV/MC

0.34

40

0.98

1.01

<10

0°F

1-24

F

9.50”

8.90”

1.30” 1.00”

35

PS

277

52112

EP228PS/MV/MC

0.15

40

0.98

1.01

<10

0°F

1-24

F

9.50”

8.90”

1.30” 1.00”

F28T5
1
2

F35T5
1

F39T5/HO
1
2

39

PS

120

50142

EP239HO/PS/MV

0.40

48

0.98

1.15

<12

0°F

1-10

J

16.90” 16.00”

1.20” 1.00”

39

PS

277

50142

EP239HO/PS/MV

0.18

48

0.98

1.15

<12

0°F

1-10

J

16.90” 16.00”

1.20” 1.00”

39

PS

120

50142

EP239HO/PS/MV

0.78

94

0.98

1.12

<10

0°F

2-8

J

16.90” 16.00”

1.20” 1.00”

39

PS

277

50142

EP239HO/PS/MV

0.34

94

0.98

1.12

<10

0°F

2-8

J

16.90” 16.00”

1.20” 1.00”

Case diagrams and wiring diagrams can be found on pages 175-177.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 173

Electronic Fluorescent Ballasts
T5
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F49T5/HO
1

2

3
4

49

PS

120

50144

EP254HO/PS/MV

0.50

59

0.99

1.00

<10

0°F

1-10

J

16.90” 16.00”

1.20” 1.00”

49

PS

277

50144

EP254HO/PS/MV

0.22

57

0.92

1.00

<10

0°F

1-10

J

16.90” 16.00”

1.20” 1.00”

49

PS

120

52114

EP254HO/PS/MV/MC

0.44

53

0.99

0.90

<10

0°F

1-24

F

9.50”

8.90”

1.30” 1.00”

49

PS

277

52114

EP254HO/PS/MV/MC

0.21

58

0.90

1.04

<10

0°F

1-24

F

9.50”

8.90”

1.30” 1.00”

49

PS

120

50144

EP254HO/PS/MV

0.94

112

0.99

0.96

<10

0°F

2-8

J

16.90” 16.00”

1.20” 1.00”

49

PS

277

50144

EP254HO/PS/MV

0.41

111

0.98

0.96

<10

0°F

2-8

J

16.90” 16.00”

1.20” 1.00”

49

PS

120

52114

EP254HO/PS/MV/MC

0.88

106

0.98

0.99

<10

0°F

2-9

F

9.50”

8.90”

1.30” 1.00”

49

PS

277

52114

EP254HO/PS/MV/MC

0.38

105

0.97

0.98

<10

0°F

2-9

F

9.50”

8.90”

1.30” 1.00”

49

PS

120

50186

EP454HO/PS/MV

0.88

106

0.98

0.97

<10

-20°F

2-22

J

16.90” 16.30”

1.80” 1.20”

49

PS

277

50186

EP454HO/PS/MV

0.39

104

0.96

0.97

<10

-20°F

2-22

J

16.90” 16.30”

1.80” 1.20”

49

PS

120

50186

EP454HO/PS/MV

1.34

162

0.98

0.97

<10

-20°F

3-10

J

16.90” 16.30”

1.80” 1.20”

49

PS

277

50186

EP454HO/PS/MV

0.61

159

0.93

0.97

<10

-20°F

3-10

J

16.90” 16.30”

1.80” 1.20”

49

PS

120

50186

EP454HO/PS/MV

1.78

214

0.98

0.97

<10

-20°F

4-7

J

16.90” 16.30”

1.80” 1.20”

49

PS

277

50186

EP454HO/PS/MV

0.78

209

0.96

0.97

<10

-20°F

4-7

J

16.90” 16.30”

1.80” 1.20”

F54T5/HO

1

2

3
4

54

RS

120

50140

E154HO/RS/120

0.75

51

0.50

0.95

<140

0°F

1-7

G

9.10”

8.75”

0.95” 0.95”

54

PS

120

50144

EP254HO/PS/MV

0.51

61

0.98

1.02

<10

0°F

1-10

J

16.90” 16.00”

1.20” 1.00”

54

PS

277

50144

EP254HO/PS/MV

0.23

61

0.98

1.02

<10

0°F

1-10

J

16.90” 16.00”

1.20” 1.00”

54

PS

120

52114

EP254HO/PS/MV/MC

0.52

62

0.98

1.03

<10

0°F

1-24

F

9.50”

8.90”

1.30” 1.00”

54

PS

277

52114

EP254HO/PS/MV/MC

0.23

62

0.90

1.03

<20

0°F

1-24

F

9.50”

8.90”

1.30” 1.00”

54

PS

120

52114

EP254HO/PS/MV/MC

1.00

120

0.98

1.00

<10

0°F

2-9

F

9.50”

8.90”

1.30” 1.00”

54

PS

277

52114

EP254HO/PS/MV/MC

0.43

117

0.97

1.00

<10

0°F

2-9

F

9.50”

8.90”

1.30” 1.00”

54

PS

120

50144

EP254HO/PS/MV

0.98

117

0.98

1.00

<10

0°F

2-8

J

16.90” 16.00”

1.20” 1.00”

54

PS

277

50144

EP254HO/PS/MV

0.42

117

0.98

1.00

<10

0°F

2-8

J

16.90” 16.00”

1.20” 1.00”

54

PS

120

50186

EP454HO/PS/MV

1.00

120

0.98

1.00

<10

-20°F

2-22

J

16.75” 16.30”

1.80” 1.20”

54

PS

277

50186

EP454HO/PS/MV

0.43

117

0.98

1.00

<10

-20°F

2-22

J

16.75” 16.30”

1.80” 1.20”

54

PS

120

50186

EP454HO/PS/MV

1.50

176

0.98

1.03

<10

-20°F

3-10

J

16.75” 16.30”

1.80” 1.20”

54

PS

277

50186

EP454HO/PS/MV

0.65

173

0.92

1.03

<10

-20°F

3-10

J

16.75” 16.30”

1.80” 1.20”

54

PS

120

50186

EP454HO/PS/MV

2.00

231

0.98

1.00

<10

-20°F

4-7

J

16.75” 16.30”

1.80” 1.20”

54

PS

277

50186

EP454HO/PS/MV

0.86

228

0.98

1.00

<10

-20°F

4-7

J

16.75” 16.30”

1.80” 1.20”

Case diagrams and wiring diagrams can be found on pages 175-177.

174

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

ELECTRONIC FLUORESCENT BALLASTS
T5
Case Diagrams

M

H
L
W

M
H

F

L

W

G

M
L

H

W

J

M
M
L

H

W
K

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 175

ELECTRONIC FLUORESCENT BALLASTS
T5
Wiring Diagrams

RED

GREEN

LAMP

RED

BALLAST

LINE

BLACK
WHITE

RED
RED
BLUE
BLUE

BALLAST

BLACK

YELLOW
YELLOW
BLUE

WHITE

1-7

LAMP

BLUE

1-10

LAMP

LAMP 2
LAMP 1

LINE

BLACK
WHITE

RED
RED
BLUE
BLUE

BALLAST

BALLAST

2-7
1-24

RED
GREEN

BLACK
WHITE
2-8

176

TOC

RED
BALLAST

YEL.
YEL.
BLUE

LAMP 2

LAMP 1

BLUE

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

ELECTRONIC FLUORESCENT BALLASTS
T5
Wiring Diagrams

LAMP 2

SW

Lamps

LAMP 1

Closed
Open

2 Lamps On

BALLAST
Neutral
or
Any Hot

2-9

2-22

SW

Lamps

SW

Lamps

Closed
Open

3 Lamps On
2 Lamps On

Closed
Open

4 Lamps On
2 Lamps On

LAMP 3
LAMP 2
LAMP 1

BALLAST

Neutral
or
Any Hot

3-10

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Neutral
or
Any Hot

4-7

TOC 177

Electronic Fluorescent Ballasts
T5 Circline
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

FC22T5
1

2

22

PS

120

50142

EP239HO/PS/MV

0.27

33

0.98

1.12

<15

0°F

1-13

J

16.90” 16.00”

1.20” 1.00”

22

PS

277

50142

EP239HO/PS/MV

0.12

33

0.95

1.12

<15

0°F

1-13

J

16.90” 16.00”

1.20” 1.00”

22

PS

120

52108

EP2CF42PS/MV/DC/K

0.27

31

0.93

1.20

<15

0°F

1-13

L

5.00”

4.63”

3.00” 1.38”

22

PS

277

52108

EP2CF42PS/MV/DC/K

0.13

31

0.93

1.20

<15

0°F

1-13

L

5.00”

4.63”

3.00” 1.38”

22

PS

120

50142

EP239HO/PS/MV

0.52

63

0.99

1.10

<10

0°F

2-13

J

16.90” 16.00”

1.20” 1.00”

22

PS

277

50142

EP239HO/PS/MV

0.23

63

0.99

1.10

<10

0°F

2-13

J

16.90” 16.00”

1.20” 1.00”

22

PS

120

52108

EP2CF42PS/MV/DC/K

0.49

59

0.97

1.10

<12

0°F

2-13

L

5.00”

4.63”

3.00” 1.38”

22

PS

277

52108

EP2CF42PS/MV/DC/K

0.22

52

0.97

1.10

<12

0°F

2-13

L

5.00”

4.63”

3.00” 1.38”

FC22T5 + FC40T5
2

22+40

PS

120

50142

*EP239HO/PS/MV

0.58

68

0.98

1.00

<12

0°F

2-13

J

16.90” 16.00”

1.20” 1.00”

22+40

PS

277

50142

*EP239HO/PS/MV

0.25

68

0.98

1.00

<12

0°F

2-13

J

16.90” 16.00”

1.20” 1.00”

22+40

PS

120

52108

*EP2CF42PS/MV/DC/K

0.55

67

0.99

0.90

<10

0°F

2-13

L

5.00”

4.63”

3.00” 1.38”

22+40

PS

277

52108

*EP2CF42PS/MV/DC/K

0.25

67

0.98

0.90

<10

0°F

2-13

L

5.00”

4.63”

3.00” 1.38”

40

PS

120

50142

EP239HO/PS/MV

0.40

48

0.98

0.92

<12

0°F

1-13

J

16.90” 16.00”

1.20” 1.00”

40

PS

277

50142

EP239HO/PS/MV

0.18

48

0.98

0.92

<12

0°F

1-13

J

16.90” 16.00”

1.20” 1.00”

40

PS

120

52106

EP2CF26PS/MV/DC/K

0.36

42

0.99

1.00

<12

0°F

1-13

L

5.00”

4.63”

2.40” 1.00”

40

PS

277

52106

EP2CF26PS/MV/DC/K

0.16

42

0.99

1.00

<12

0°F

1-13

L

5.00”

4.63”

2.40” 1.00”

40

PS

120

52108

EP2CF42PS/MV/DC/K

0.37

45

0.99

1.00

<15

0°F

1-13

L

5.00”

4.63”

3.00” 1.38”

40

PS

277

52108

EP2CF42PS/MV/DC/K

0.17

45

0.99

1.00

<15

0°F

1-13

L

5.00”

4.63”

3.00” 1.38”

40

PS

120

50142

EP239HO/PS/MV

0.77

92

0.98

0.90

<12

0°F

2-13

J

16.90” 16.00”

1.20” 1.00”

40

PS

277

50142

EP239HO/PS/MV

0.33

92

0.98

0.90

<12

0°F

2-13

J

16.90” 16.00”

1.20” 1.00”

40

PS

120

52108

EP2CF42PS/MV/DC/K

0.69

82

0.99

0.95

<12

0°F

2-13

L

5.00”

4.63”

3.00” 1.38”

40

PS

277

52108

EP2CF42PS/MV/DC/K

0.30

82

0.99

0.95

<12

0°F

2-13

L

5.00”

4.63”

3.00” 1.38”

FC40T5

1

2

FC55T5/HO
1
2

55

PS

120

50144

EP254HO/PS/MV

0.46

55

0.96

0.81

<15

0°F

1-13

J

16.90” 16.00”

1.20” 1.00”

55

PS

277

50144

EP254HO/PS/MV

0.21

55

0.96

0.81

<15

0°F

1-13

J

16.90” 16.00”

1.20” 1.00”

55

PS

120

50144

EP254HO/PS/MV

0.89

106

0.98

0.85

<10

0°F

2-13

J

16.90” 16.00”

1.20” 1.00”

55

PS

277

50144

EP254HO/PS/MV

0.38

103

0.98

0.85

<10

0°F

2-13

J

16.90” 16.00”

1.20” 1.00”

*Ballast operates two different lamps together.
Case diagrams and wiring diagrams can be found on page 179.

178

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

ELECTRONIC FLUORESCENT BALLASTS
T5 Circline
Case Diagrams

M
L

H

W

J

H
M
L

W
L

Wiring Diagrams

GREEN
BLACK
WHITE

BALLAST

RED
RED
YEL
YEL
BLUE
BLUE

1-13

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

GREEN
BLACK
WHITE

BALLAST

RED
RED
YEL
YEL
BLUE
BLUE

2-13

TOC 179

Electronic Fluorescent Ballasts
T8
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F14T8
1

14

RS

120

50108

VE120RS/120

0.24

15.5

0.54

1.00

<150

0°F

1-18

F

6.46”

6.00”

1.37” 1.00”

2

14

RS

120

50110

E220RS/120

0.44

29

0.54

0.88

<130

0°F

2-12

F

6.46”

6.00”

1.37” 1.00”

F15T8
1

15

RS

120

50108

VE120RS/120

0.25

16

0.55

1.00

<140

0°F

1-18

F

6.46”

6.00”

1.37” 1.00”

2

15

RS

120

50110

E220RS/120

0.49

32

0.56

1.00

<130

0°F

2-12

F

6.46”

6.00”

1.37” 1.00”

F17T8, FB16

1

2

17

RS

120

50108

VE120RS/120

0.27

18.5

0.56

1.00

<140

0°F

1-18

F

6.46”

6.00”

1.37” 1.00”

17

IS

120

50118

E232IS/120/R/MC

0.35

20

0.45

1.05

<150

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

17

IS

120

50112

EP132IS/MV/MC

0.15

17

0.99

0.91

<10

0°F

1-3

F

9.50”

8.90”

1.30” 1.00”

17

IS

277

50112

EP132IS/MV/MC

0.07

17

0.95

0.91

<15

0°F

1-3

F

9.50”

8.90”

1.30” 1.00”

17

IS

120

50115

EP232IS/H/MV/HE

0.22

25

0.95

1.42

<10

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50115

EP232IS/H/MV/HE

0.11

25

0.95

1.42

<15

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

17

IS

120

50119

EP232IS/L/MV/HE

0.14

17

0.98

0.96

<10

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50119

EP232IS/L/MV/HE

0.08

16

0.80

0.96

<20

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

17

IS

120

50123

EP232IS/MV/HE

0.16

21

0.98

1.10

<10

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50123

EP232IS/MV/HE

0.09

21

0.95

1.10

<15

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

17

IS

120

50116

EP232IS/MV/MC

0.18

22

0.98

1.10

<10

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50116

EP232IS/MV/MC

0.08

21

0.95

1.10

<15

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

17

PS

120

50180

EP232PS/MV/HE

0.20

23

0.98

1.03

<10

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

17

PS

277

50180

EP232PS/MV/HE

0.09

24

0.93

1.03

<12

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

17

PS

120

50178

EP232PS/L/MV/HE

0.28

33

0.99

0.86

<10

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

17

PS

277

50178

EP232PS/L/MV/HE

0.12

33

0.98

0.86

<10

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

17

RS

120

50110

E220RS/120

0.54

36

0.58

1.00

<130

0°F

2-12

F

6.46”

6.00”

1.37” 1.00”

17

IS

120

50118

E232IS/120/R/MC

0.52

31

0.52

0.86

<160

0°F

2-17

F

9.50”

8.90”

1.30” 1.00”

17

IS

120

50176

EP232IS/120/MC

0.31

33

0.90

0.86

<35

0°F

2-17

F

9.50”

8.90”

1.30” 1.00”

17

IS

120

50115

EP232IS/H/MV/HE

0.33

39

0.98

1.23

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50115

EP232IS/H/MV/HE

0.15

39

0.96

1.23

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

17

IS

120

50119

EP232IS/L/MV/HE

0.21

25

0.98

0.80

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50119

EP232IS/L/MV/HE

0.09

23

0.85

0.80

<20

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

17

IS

120

50123

EP232IS/MV/HE

0.25

28

0.98

0.91

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50123

EP232IS/MV/HE

0.11

28

0.97

0.91

<15

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

17

IS

120

50116

EP232IS/MV/MC

0.26

31

0.98

0.91

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50116

EP232IS/MV/MC

0.12

31

0.97

0.91

<15

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

17

PS

120

50180

EP232PS/MV/HE

0.30

34

0.98

0.90

<10

0°F

2-24

F

9.50”

8.90”

1.38” 1.18”

17

PS

277

50180

EP232PS/MV/HE

0.13

35

0.96

0.90

<10

0°F

2-24

F

9.50”

8.90”

1.38” 1.18”

17

PS

120

50178

EP232PS/L/MV/HE

0.44

52

0.99

0.77

<10

0°F

2-24

F

9.50”

8.90”

1.38” 1.18”

17

PS

277

50178

EP232PS/L/MV/HE

0.19

52

0.98

0.77

<10

0°F

2-24

F

9.50”

8.90”

1.38” 1.18”

V

Item will be discontinued when inventory is depleted.

Case diagrams and wiring diagrams can be found on pages 190-192.

180

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Electronic Fluorescent Ballasts
T8
Lamp Type
Start
Type

Qty. Watts

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F17T8, FB16 continued

3

4

17

IS

120

50121

EP332IS/H/MV/HE

0.49

58

0.99

1.23

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50121

EP332IS/H/MV/HE

0.22

57

0.96

1.23

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

17

IS

120

50168

EP332IS/L/MV/HE

0.37

43

0.98

0.86

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50168

EP332IS/L/MV/HE

0.16

43

0.95

0.86

<15

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

17

IS

120

50170

EP332IS/MV/HE

0.38

45

0.98

0.92

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50170

EP332IS/MV/HE

0.17

45

0.96

0.92

<15

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

17

IS

120

50122

EP332IS/MV/MC

0.38

45

0.98

0.90

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50122

EP332IS/MV/MC

0.17

45

0.96

0.90

<15

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

17

PS

120

50184

EP432PS/MV/HE

0.45

53

0.98

0.94

<10

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

17

PS

277

50184

EP432PS/MV/HE

0.21

53

0.95

0.94

<15

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

17

PS

120

50182

EP432PS/L/MV/HE

0.40

48

0.99

0.81

<10

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

17

PS

277

50182

EP432PS/L/MV/HE

0.18

49

0.96

0.82

<12

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

17

IS

120

50158

E432IS/120/R/MC

0.97

67

0.50

0.95

<175

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

17

IS

120

50124

EP432IS/120/MC

0.51

61

0.98

0.96

<20

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

17

IS

120

50172

EP432IS/L/MV/HE

0.46

54

0.98

0.79

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.18”

17

IS

277

50172

EP432IS/L/MV/HE

0.19

52

0.98

0.79

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.18”

17

IS

120

50174

EP432IS/MV/HE

0.49

59

0.98

0.93

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50174

EP432IS/MV/HE

0.22

58

0.98

0.93

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

17

IS

120

50126

EP432IS/MV/MC

0.49

59

0.98

0.90

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

17

IS

277

50126

EP432IS/MV/MC

0.22

58

0.98

0.90

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

17

PS

120

50184

EP432PS/MV/HE

0.52

63

0.98

0.87

<10

0°F

4-5

F

9.50”

8.90”

1.65” 1.18”

17

PS

277

50184

EP432PS/MV/HE

0.24

63

0.97

0.89

<12

0°F

4-5

F

9.50”

8.90”

1.65” 1.18”

17

PS

120

50182

EP432PS/L/MV/HE

0.46

55

0.99

0.73

<10

0°F

4-5

F

9.50”

8.90”

1.65” 1.18”

17

PS

277

50182

EP432PS/L/MV/HE

0.21

56

0.97

0.74

<12

0°F

4-5

F

9.50”

8.90”

1.65” 1.18”

F18T8 24”
1

18

RS

120

50108

E120RS/120

0.26

17.5

0.55

0.95

<140

0°F

1-18

F

6.46”

6.00”

1.37” 1.00”

2

18

RS

120

50110

E220RS/120

0.50

34

0.57

0.92

<150

0°F

2-12

F

6.46”

6.00”

1.37” 1.00”

RS

120

50108

E120RS/120

0.26

18

0.56

0.90

<130

0°F

1-18

F

6.46”

6.00”

1.37” 1.00”

F20T8
1

20

Case diagrams and wiring diagrams can be found on pages 190-192.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 181

Electronic Fluorescent Ballasts
T8
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F25T8/ES (F32T8 25W)

1

2

3

25

IS

120

50119

EP232IS/L/MV/HE

0.21

25

0.98

0.93

<10

60°F

1-3

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50119

EP232IS/L/MV/HE

0.10

23

0.80

0.93

<20

60°F

1-3

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50123

EP232IS/MV/HE

0.24

29

0.98

1.08

<10

60°F

1-3

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50123

EP232IS/MV/HE

0.11

29

0.97

1.08

<15

60°F

1-3

F

9.50”

8.90”

1.30” 1.10”

25

PS

120

50180

EP232PS/MV/HE

0.27

33

0.99

1.05

<10

60°F

1-11

F

9.50”

8.90”

1.38” 1.18”

25

PS

277

50180

EP232PS/MV/HE

0.12

33

0.95

1.05

<12

60°F

1-11

F

9.50”

8.90”

1.38” 1.18”

25

PS

120

50178

EP232PS/L/MV/HE

0.24

28

0.99

0.92

<10

60°F

1-11

F

9.50”

8.90”

1.38” 1.18”

25

PS

277

50178

EP232PS/L/MV/HE

0.11

29

0.97

0.92

<12

60°F

1-11

F

9.50”

8.90”

1.38” 1.18”

25

IS

120

50119

EP232IS/L/MV/HE

0.31

37

0.98

0.79

<10

60°F

2-17

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50119

EP232IS/L/MV/HE

0.13

35

0.95

0.79

<15

60°F

2-17

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50123

EP232IS/MV/HE

0.39

46

0.98

0.89

<10

60°F

2-17

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50123

EP232IS/MV/HE

0.17

45

0.97

0.89

<15

60°F

2-17

F

9.50”

8.90”

1.30” 1.10”

25

PS

120

50178

EP232PS/L/MV/HE

0.37

44

0.99

0.79

<10

60°F

2-24

F

9.50”

8.90”

1.38” 1.18”

25

PS

277

50178

EP232PS/L/MV/HE

0.16

44

0.98

0.79

<10

60°F

2-24

F

9.50”

8.90”

1.38” 1.18”

25

PS

120

50180

EP232PS/MV/HE

0.42

50

0.99

0.92

<10

60°F

2-24

F

9.50”

8.90”

1.38” 1.18”

25

PS

277

50180

EP232PS/MV/HE

0.19

50

0.97

0.92

<10

60°F

2-24

F

9.50”

8.90”

1.38” 1.18”

25

IS

120

50168

EP332IS/L/MV/HE

0.41

48

0.98

0.95

<10

60°F

2-11

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50168

EP332IS/L/MV/HE

0.18

47

0.95

0.92

<15

60°F

2-11

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50170

EP332IS/MV/HE

0.43

51

0.98

1.00

<10

60°F

2-11

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50170

EP332IS/MV/HE

0.19

51

0.97

1.00

<15

60°F

2-11

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50168

EP332IS/L/MV/HE

0.53

63

0.98

0.85

<10

60°F

3-7

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50168

EP332IS/L/MV/HE

0.23

61

0.95

0.85

<15

60°F

3-7

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50170

EP332IS/MV/HE

0.56

68

0.98

0.90

<10

60°F

3-7

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50170

EP332IS/MV/HE

0.25

68

0.97

0.90

<15

60°F

3-7

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50172

EP432IS/L/MV/HE

0.57

68

0.98

0.84

<10

60°F

3-9

F

9.50”

8.90”

1.30” 1.18”

25

IS

277

50172

EP432IS/L/MV/HE

0.25

68

0.95

0.84

<15

60°F

3-9

F

9.50”

8.90”

1.30” 1.18”

25

IS

120

50174

EP432IS/MV/HE

0.62

74

0.98

0.96

<10

60°F

3-9

F

9.50”

8.90”

1.30” 1.18”

25

IS

277

50174

EP432IS/MV/HE

0.27

73

0.98

0.96

<10

60°F

3-9

F

9.50”

8.90”

1.30” 1.18”

25

PS

120

50184

EP432PS/MV/HE

0.64

76

0.99

0.94

<10

60°F

3-8

F

9.50”

8.90”

1.65” 1.18”

25

PS

277

50184

EP432PS/MV/HE

0.28

76

0.98

0.94

<10

60°F

3-8

F

9.50”

8.90”

1.65” 1.18”

25

PS

120

50182

EP432PS/L/MV/HE

0.56

67

0.99

0.81

<10

60°F

3-8

F

9.50”

8.90”

1.65” 1.18”

25

PS

277

50182

EP432PS/L/MV/HE

0.25

68

0.98

0.82

<10

60°F

3-8

F

9.50”

8.90”

1.65” 1.18”

Case diagrams and wiring diagrams can be found on pages 190-192.

182

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Electronic Fluorescent Ballasts
T8
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F25T8/ES (F32T8 25W) continued

4

25

IS

120

50172

EP432IS/L/MV/HE

0.69

82

0.98

0.78

<10

60°F

4-6

F

9.50”

8.90”

1.30” 1.18”

25

IS

277

50172

EP432IS/L/MV/HE

0.30

81

0.98

0.78

<10

60°F

4-6

F

9.50”

8.90”

1.30” 1.18”

25

IS

120

50174

EP432IS/MV/HE

0.74

88

0.98

0.88

<10

60°F

4-6

F

9.50”

8.90”

1.30” 1.18”

25

IS

277

50174

EP432IS/MV/HE

0.32

88

0.98

0.88

<10

60°F

4-6

F

9.50”

8.90”

1.30” 1.18”

25

PS

120

50184

EP432PS/MV/HE

0.77

93

0.99

0.89

<10

60°F

4-5

F

9.50”

8.90”

1.65” 1.18”

25

PS

277

50184

EP432PS/MV/HE

0.34

93

0.98

0.89

<10

60°F

4-5

F

9.50”

8.90”

1.65” 1.18”

25

PS

120

50182

EP432PS/L/MV/HE

0.67

80

0.99

0.75

<10

60°F

4-5

F

9.50”

8.90”

1.65” 1.18”

25

PS

277

50182

EP432PS/L/MV/HE

0.30

81

0.98

0.76

<10

60°F

4-5

F

9.50”

8.90”

1.65” 1.18”

F25T8, FB24

1

2

25

IS

120

50118

E232IS/120/R/MC

0.46

27

0.50

1.01

<170

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50112

EP132IS/MV/MC

0.21

24

0.99

0.92

<10

0°F

1-23

F

9.50”

8.90”

1.30” 1.00”

25

IS

277

50112

EP132IS/MV/MC

0.10

24

0.97

0.92

<10

0°F

1-23

F

9.50”

8.90”

1.30” 1.00”

25

IS

120

50115

EP232IS/H/MV/HE

0.28

33

0.98

1.40

<10

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50115

EP232IS/H/MV/HE

0.13

33

0.96

1.40

<15

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50119

EP232IS/L/MV/HE

0.20

24

0.98

0.95

<10

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50119

EP232IS/L/MV/HE

0.09

22

0.80

0.95

<20

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50123

EP232IS/MV/HE

0.23

26

0.98

1.08

<10

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50123

EP232IS/MV/HE

0.10

26

0.96

1.08

<15

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50116

EP232IS/MV/MC

0.24

29

0.98

1.08

<10

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50116

EP232IS/MV/MC

0.11

28

0.96

1.08

<15

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

25

PS

120

50180

EP232PS/MV/HE

0.26

31

0.98

1.01

<10

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

25

PS

277

50180

EP232PS/MV/HE

0.12

32

0.95

1.01

<12

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

25

PS

120

50178

EP232PS/L/MV/HE

0.23

27

0.99

0.88

<10

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

25

PS

277

50178

EP232PS/L/MV/HE

0.10

28

0.97

0.88

<12

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

25

IS

120

50118

E232IS/120/R/MC

0.65

43

0.54

0.84

<140

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50176

EP232IS/120/MC

0.41

47

0.96

0.85

<30

0°F

2-17

F

9.50”

8.90”

1.30” 1.00”

25

IS

120

50115

EP232IS/H/MV/ME

0.45

54

0.98

1.20

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50115

EP232IS/H/MV/ME

0.20

54

0.97

1.20

<15

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50119

EP232IS/L/MV/HE

0.31

37

0.98

0.79

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50119

EP232IS/L/MV/HE

0.13

35

0.95

0.79

<15

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50123

EP232IS/MV/HE

0.36

42

0.98

0.89

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50123

EP232IS/MV/HE

0.16

41

0.98

0.89

<15

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50116

EP232IS/MV/MC

0.38

46

0.98

0.89

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50116

EP232IS/MV/MC

0.17

46

0.97

0.89

<15

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

25

PS

120

50180

EP232PS/MV/HE

0.40

47

0.99

0.83

<10

0°F

2-24

F

9.50”

8.90”

1.38” 1.18”

Case diagrams and wiring diagrams can be found on pages 190-192.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 183

Electronic Fluorescent Ballasts
T8
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F25T8, FB24 continued

2

3

4

25

PS

277

50180

EP232PS/MV/HE

0.18

47

0.95

0.88

<10

0°F

2-24

F

9.50”

8.90”

1.38” 1.18”

25

PS

120

50178

EP232PS/L/MV/HE

0.35

41

0.99

0.74

<10

0°F

2-24

F

9.50”

8.90”

1.38” 1.18”

25

PS

277

50178

EP232PS/L/MV/HE

0.15

41

0.98

0.74

<10

0°F

2-24

F

9.50”

8.90”

1.38” 1.18”

25

IS

120

50121

EP332IS/H/MV/HE

0.55

65

0.98

1.28

<10

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50121

EP332IS/H/MV/HE

0.25

65

0.97

1.28

<15

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50170

EP332IS/MV/HE

0.42

50

0.98

1.00

<10

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50170

EP332IS/MV/HE

0.18

50

0.96

1.00

<15

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50122

EP332IS/MV/MC

0.42

50

0.98

0.98

<10

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50122

EP332IS/MV/MC

0.18

50

0.96

0.98

<15

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50121

EP332IS/H/MV/HE

0.39

81

0.98

1.20

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50121

EP332IS/H/MV/HE

0.30

81

0.98

1.20

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50168

EP332IS/L/MV/HE

0.51

60

0.98

0.82

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50168

EP332IS/L/MV/HE

0.22

58

0.95

0.82

<15

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50170

EP332IS/MV/HE

0.56

68

0.98

0.90

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50170

EP332IS/MV/HE

0.24

68

0.97

0.90

<15

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50122

EP332IS/MV/MC

0.56

68

0.98

0.88

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50122

EP332IS/MV/MC

0.24

66

0.97

0.88

<15

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50158

E432IS/120/R/MC

1.12

77

0.50

1.00

<175

0°F

3-9

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50124

EP432IS/120/MC

0.62

74

0.98

1.04

<20

0°F

3-9

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50172

EP432IS/L/MV/HE

0.53

62

0.98

0.84

<10

0°F

3-9

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50172

EP432IS/L/MV/HE

0.23

61

0.95

0.84

<15

0°F

3-9

F

9.50”

8.90”

1.30” 1.10”

25

PS

120

50184

EP432PS/MV/HE

0.62

74

0.98

0.90

<10

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

25

PS

277

50184

EP432PS/MV/HE

0.28

74

0.97

0.90

<12

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

25

PS

120

50182

EP432PS/L/MV/HE

0.55

65

0.99

0.80

<10

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

25

PS

277

50182

EP432PS/L/MV/HE

0.24

66

0.98

0.80

<10

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

25

IS

120

50158

E432IS/R/120/MC

1.25

86

0.50

0.86

<170

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50124

EP432IS/120/MC

0.74

89

0.98

0.94

<20

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50172

EP432IS/L/MV/HE

0.64

76

0.98

0.78

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50172

EP432IS/L/MV/HE

0.27

74

0.98

0.78

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50174

EP432IS/MV/HE

0.73

87

0.98

0.89

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50174

EP432IS/MV/HE

0.32

85

0.98

0.89

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

25

IS

120

50126

EP432IS/MV/MC

0.72

87

0.98

0.86

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

25

IS

277

50126

EP432IS/MV/MC

0.32

85

0.98

0.86

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

25

PS

120

50184

EP432PS/MV/HE

0.74

88

0.99

0.84

<10

0°F

4-5

F

9.50”

8.90”

1.65” 1.18”

25

PS

277

50184

EP432PS/MV/HE

0.33

88

0.98

0.85

<10

0°F

4-5

F

9.50”

8.90”

1.65” 1.18”

25

PS

120

50182

EP432PS/L/MV/HE

0.65

77

0.99

0.73

<10

0°F

4-5

F

9.50”

8.90”

1.65” 1.18”

25

PS

277

50182

EP432PS/L/MV/HE

0.29

78

0.98

0.73

<10

0°F

4-5

F

9.50”

8.90”

1.65” 1.18”

Case diagrams and wiring diagrams can be found on pages 190-192.

184

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Electronic Fluorescent Ballasts
T8
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F28T8

1

2

28

IS

120

50115

EP232IS/H/MV/HE

0.33

39

0.98

1.38

<10

60°F

1-3

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50115

EP232IS/H/MV/HE

0.15

39

0.97

1.38

<15

60°F

1-3

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50119

EP232IS/L/MV/HE

0.22

26

0.98

0.93

<10

60°F

1-3

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50119

EP232IS/L/MV/HE

0.10

24

0.85

0.93

<20

60°F

1-3

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50123

EP232IS/MV/HE

0.25

30

0.98

1.08

<10

60°F

1-3

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50123

EP232IS/MV/HE

0.11

29

0.97

1.08

<15

60°F

1-3

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50116

EP232IS/MV/MC

0.26

31

0.98

1.08

<10

60°F

1-3

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50116

EP232IS/MV/MC

0.12

31

0.97

1.08

<10

60°F

1-3

F

9.50”

8.90”

1.30” 1.10”

28

PS

120

50180

EP232PS/MV/HE

0.29

35

0.99

1.06

<10

60°F

1-11

F

9.50”

8.90”

1.38” 1.18”

28

PS

277

50180

EP232PS/MV/HE

0.13

35

0.96

1.06

<10

60°F

1-11

F

9.50”

8.90”

1.38” 1.18”

28

PS

120

50178

EP232PS/L/MV/HE

0.25

30

0.99

0.86

<10

60°F

1-11

F

9.50”

8.90”

1.38” 1.18”

28

PS

277

50178

EP232PS/L/MV/HE

0.11

30

0.97

0.86

<12

60°F

1-11

F

9.50”

8.90”

1.38” 1.18”

28

IS

120

50115

EP232IS/H/MV/HE

0.54

64

0.98

1.18

<10

60°F

2-17

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50115

EP232IS/H/MV/HE

0.24

63

0.98

1.18

<15

60°F

2-17

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50119

EP232IS/L/MV/HE

0.35

41

0.98

0.78

<10

60°F

2-17

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50119

EP232IS/L/MV/HE

0.15

41

0.97

0.78

<15

60°F

2-17

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50123

EP232IS/MV/HE

0.41

49

0.98

0.89

<10

60°F

2-17

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50123

EP232IS/MV/HE

0.18

47

0.97

0.89

<15

60°F

2-17

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50116

EP232IS/MV/MC

0.41

49

0.98

0.89

<10

60°F

2-17

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50116

EP232IS/MV/MC

0.18

48

0.97

0.89

<15

60°F

2-17

F

9.50”

8.90”

1.30” 1.10”

28

PS

120

50180

EP232PS/MV/HE

0.45

54

0.99

0.90

<10

60°F

2-24

F

9.50”

8.90”

1.38” 1.18”

28

PS

277

50180

EP232PS/MV/HE

0.20

54

0.98

0.90

<10

60°F

2-24

F

9.50”

8.90”

1.38” 1.18”

28

PS

120

50178

EP232PS/L/MV/HE

0.39

46

0.99

0.75

<10

60°F

2-24

F

9.50”

8.90”

1.38” 1.18”

28

PS

277

50178

EP232PS/L/MV/HE

0.17

47

0.98

0.75

<10

60°F

2-24

F

9.50”

8.90”

1.38” 1.18”

28

IS

120

50121

EP332IS/H/MV/HE

0.59

70

0.98

1.27

<10

60°F

2-11

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50121

EP332IS/H/MVHE

0.26

69

0.97

1.27

<15

60°F

2-11

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50168

EP332IS/L/MV/HE

0.42

49

0.98

0.92

<10

60°F

2-11

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50168

EP332IS/L/MV/HE

0.19

48

0.95

0.92

<15

60°F

2-11

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50170

EP332IS/MV/HE

0.45

54

0.98

0.99

<10

60°F

2-11

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50170

EP332IS/MV/HE

0.20

53

0.97

0.99

<15

60°F

2-11

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50122

EP332IS/MV/MC

0.45

54

0.98

0.97

<10

60°F

2-11

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50122

EP332IS/MV/MC

0.20

53

0.97

0.97

<15

60°F

2-11

F

9.50”

8.90”

1.30” 1.10”

Case diagrams and wiring diagrams can be found on pages 190-192.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 185

Electronic Fluorescent Ballasts
T8
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F28T8 continued

3

4

28

IS

120

50121

EP332IS/H/MV/HE

0.78

93

0.98

1.18

<10

60°F

3-7

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50121

EP332IS/H/MV/HE

0.34

92

0.98

1.18

<10

60°F

3-7

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50168

EP332IS/L/MV/HE

0.55

64

0.98

0.81

<10

60°F

3-7

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50168

EP332IS/L/MV/HE

0.24

63

0.95

0.81

<15

60°F

3-7

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50170

EP332IS/MV/HE

0.60

72

0.98

0.88

<10

60°F

3-7

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50170

EP332IS/MV/HE

0.26

70

0.98

0.88

<15

60°F

3-7

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50122

EP332IS/MV/MC

0.60

72

0.98

0.86

<10

60°F

3-7

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50122

EP332IS/MV/MC

0.26

70

0.98

0.86

<15

60°F

3-7

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50172

EP432IS/L/MV/HE

0.59

70

0.98

0.82

<10

60°F

3-9

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50172

EP432IS/L/MV/HE

0.26

70

0.97

0.82

<10

60°F

3-9

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50174

EP432IS/MV/HE

0.65

77

0.96

0.98

<10

60°F

3-9

F

9.50”

8.90”

1.30” 1.10”

9.50”

8.90”

1.30” 1.10”

28

IS

277

50174

EP432IS/MV/HE

0.29

77

0.96

0.98

<10

60°F

3-9

F

28

IS

120

50126

EP432IS/MV/MC

0.65

77

0.98

0.92

<10

60°F

3-9

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50126

EP432IS/MV/MC

0.29

77

0.97

0.92

<10

60°F

3-9

F

9.50”

8.90”

1.30” 1.10”

28

PS

120

50184

EP432PS/MV/HE

0.70

83

0.99

0.92

<10

60°F

3-8

F

9.50”

8.90”

1.65” 1.18”

28

PS

277

50184

EP432PS/MV/HE

0.31

83

0.97

0.93

<12

60°F

3-8

F

9.50”

8.90”

1.65” 1.18”

28

PS

120

50182

VEP432PS/L/MV/HE

0.61

72

0.99

0.80

<10

60°F

3-8

F

9.50”

8.90”

1.65” 1.18”

28

PS

277

50182

VEP432PS/L/MV/HE

0.27

73

0.98

0.82

<10

60°F

3-8

F

9.50”

8.90”

1.65” 1.18”

28

IS

120

50172

EP432IS/L/MV/HE

0.71

84

0.98

0.77

<10

60°F

4-6

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50172

EP432IS/L/MV/HE

0.31

84

0.98

0.77

<10

60°F

4-6

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50174

EP432IS/MV/HE

0.79

94

0.98

0.88

<10

60°F

4-6

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50174

EP432IS/MV/HE

0.35

94

0.98

0.88

<10

60°F

4-6

F

9.50”

8.90”

1.30” 1.10”

28

IS

120

50126

EP432IS/MV/MC

0.79

94

0.98

0.85

<10

60°F

4-6

F

9.50”

8.90”

1.30” 1.10”

28

IS

277

50126

EP432IS/MV/MC

0.35

94

0.98

0.85

<10

60°F

4-6

F

9.50”

8.90”

1.30” 1.10”

28

PS

120

50184

EP432PS/MV/HE

0.84

100

0.99

0.85

<10

60°F

4-5

F

9.50”

8.90”

1.65” 1.18”

28

PS

277

50184

EP432PS/MV/HE

0.37

100

0.98

0.86

<10

60°F

4-5

F

9.50”

8.90”

1.65” 1.18”

28

PS

120

50182

VEP432PS/L/MV/HE

0.73

87

0.99

0.73

<10

60°F

4-5

F

9.50”

8.90”

1.65” 1.18”

28

PS

277

50182

VEP432PS/L/MV/HE

0.32

88

0.98

0.75

<10

60°F

4-5

F

9.50”

8.90”

1.65” 1.18”

V

Item will be discontinued when inventory is depleted.

Case diagrams and wiring diagrams can be found on pages 190-192.

186

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Electronic Fluorescent Ballasts
T8
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F32T8, FB32, FB31

1

2

32

IS

120

50118

E232IS/120/R/MC

0.55

34

0.52

1.03

<155

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50112

EP132IS/MV/MC

0.26

31

0.99

0.88

<10

0°F

1-23

F

9.50”

8.90”

1.30” 1.00”

32

IS

277

50112

EP132IS/MV/MC

0.12

31

0.98

0.88

<10

0°F

1-23

F

9.50”

8.90”

1.30” 1.00”

32

IS

120

50176

EP232IS/120/MC

0.34

38

0.94

1.01

<32

0°F

1-3

F

9.50”

8.90”

1.30” 1.00”

32

IS

120

50115

EP232IS/H/MV/HE

0.37

45

0.98

1.38

<10

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50115

EP232IS/H/MV/HE

0.17

45

0.97

1.38

<15

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50119

EP232IS/L/MV/HE

0.26

31

0.98

0.93

<10

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50119

EP232IS/L/MV/HE

0.12

30

0.95

0.93

<15

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50123

EP232IS/MV/HE

0.29

35

0.98

1.08

<10

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50123

EP232IS/MV/HE

0.13

34

0.97

1.08

<15

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50116

EP232IS/MV/MC

0.32

39

0.98

1.08

<12

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50116

EP232IS/MV/MC

0.14

38

0.97

1.08

<15

0°F

1-3

F

9.50”

8.90”

1.30” 1.10”

32

PS

120

50180

EP232PS/MV/HE

0.31

37

0.98

0.99

<10

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

32

PS

277

50180

EP232PS/MV/HE

0.14

37

0.93

0.99

<10

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

32

PS

120

50178

EP232PS/L/MV/HE

0.28

33

0.99

0.86

<10

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

32

PS

277

50178

EP232PS/L/MV/HE

0.12

33

0.98

0.86

<10

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

32

IS

120

50118

E232IS/120/R/MC

0.80

54

0.56

0.85

<130

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50176

EP232IS/120/MC

0.49

59

0.97

0.87

<30

0°F

2-17

F

9.50”

8.90”

1.30” 1.00”

32

IS

120

50115

EP232IS/H/MV/HE

0.62

74

0.98

1.18

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50115

EP232IS/H/MV/HE

0.27

73

0.98

1.18

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50119

EP232IS/L/MV/HE

0.40

49

0.98

0.78

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50119

EP232IS/L/MV/HE

0.18

48

0.97

0.78

<15

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50123

EP232IS/MV/HE

0.46

56

0.98

0.89

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50123

EP232IS/MV/HE

0.20

55

0.97

0.89

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50116

EP232IS/MV/MC

0.50

59

0.98

0.89

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50116

EP232IS/MV/MC

0.21

57

0.98

0.89

<10

0°F

2-17

F

9.50”

8.90”

1.30” 1.10”

32

PS

120

50180

EP232PS/MV/HE

0.50

60

0.99

0.88

<10

0°F

2-24

F

9.50”

8.90”

1.38” 1.18”

32

PS

277

50180

EP232PS/MV/HE

0.22

60

0.98

0.88

<10

0°F

2-24

F

9.50”

8.90”

1.38” 1.18”

32

PS

120

50178

EP232PS/L/MV/HE

0.44

52

0.99

0.77

<10

0°F

2-24

F

9.50”

8.90”

1.38” 1.18”

32

PS

277

50178

EP232PS/L/MV/HE

0.19

52

0.98

0.77

<10

0°F

2-24

F

9.50”

8.90”

1.38” 1.18”

32

IS

120

50121

EP332IS/H/MV/HE

0.69

81

0.98

1.27

<10

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50121

EP332IS/H/MV/HE

0.30

80

0.98

1.27

<10

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50168

EP332IS/L/MV/HE

0.49

58

0.98

0.92

<10

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50168

EP332IS/L/MV/HE

0.21

57

0.95

0.92

<15

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50170

EP332IS/MV/HE

0.53

63

0.98

0.99

<10

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50170

EP332IS/MV/HE

0.24

63

0.97

0.99

<15

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50122

EP332IS/MV/MC

0.53

63

0.98

0.97

<10

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50122

EP332IS/MV/MC

0.24

63

0.97

0.97

<15

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

Case diagrams and wiring diagrams can be found on pages 190-192.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 187

Electronic Fluorescent Ballasts
T8
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F32T8, FB32, FB31 continued

3

4

32

IS

120

50158

E432IS/R/120/MC

1.35

86

0.50

0.90

<170

0°F

3-9

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50121

EP332IS/H/MV/HE

0.91

108

0.98

1.18

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50121

EP332IS/H/MV/HE

0.39

106

0.98

1.18

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50168

EP332IS/L/MV/HE

0.64

76

0.98

0.78

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50168

EP332IS/L/MV/HE

0.27

74

0.98

0.78

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50170

EP332IS/MV/HE

0.71

84

0.98

0.88

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50170

EP332IS/MV/HE

0.31

83

0.98

0.88

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50122

EP332IS/MV/MC

0.71

84

0.98

0.86

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50122

EP332IS/MV/MC

0.31

83

0.98

0.86

<10

0°F

3-7

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50124

EP432IS/120/MC

0.79

94

0.98

1.00

<20

0°F

3-9

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50172

EP432IS/L/MV/HE

0.68

81

0.98

0.82

<10

0°F

3-9

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50172

EP432IS/L/MV/HE

0.29

80

0.98

0.82

<10

0°F

3-9

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50174

EP432IS/MV/HE

0.77

92

0.98

0.96

<10

0°F

3-9

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50174

EP432IS/MV/HE

0.34

89

0.98

0.96

<10

0°F

3-9

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50126

EP432IS/MV/MC

0.77

92

0.98

0.92

<10

0°F

3-9

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50126

EP432IS/MV/MC

0.34

89

0.98

0.92

<10

0°F

3-9

F

9.50”

8.90”

1.30” 1.10”

32

PS

120

50184

EP432PS/MV/HE

0.79

95

0.99

0.92

<10

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

32

PS

277

50184

EP432PS/MV/HE

0.35

95

0.98

0.93

<10

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

32

PS

120

50182

VEP432PS/L/MV/HE

0.66

78

0.99

0.78

<10

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

32

PS

277

50182

VEP432PS/L/MV/HE

0.29

78

0.98

0.79

<10

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

32

IS

120

50158

E432IS/120/R/MC

1.62

103

0.50

0.82

<165

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50124

EP432IS/120/MC

0.93

110

0.98

0.88

<20

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50172

EP432IS/L/MV/HE

0.82

98

0.98

0.77

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50172

EP432IS/L/MV/HE

0.35

96

0.98

0.77

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50174

EP432IS/MV/HE

0.93

112

0.99

0.88

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50174

EP432IS/MV/HE

0.40

109

0.99

0.88

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

32

IS

120

50126

EP432IS/MV/MC

0.93

112

0.98

0.85

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

32

IS

277

50126

EP432IS/MV/MC

0.40

108

0.98

0.85

<10

0°F

4-6

F

9.50”

8.90”

1.30” 1.10”

32

PS

120

50184

EP432PS/MV/HE

0.95

114

0.99

0.86

<10

0°F

4-5

F

9.50”

8.90”

1.65” 1.18”

32

PS

277

50184

EP432PS/MV/HE

0.42

114

0.98

0.86

<10

0°F

4-5

F

9.50”

8.90”

1.65” 1.18”

32

PS

120

50182

VEP432PS/L/MV/HE

0.82

97

0.99

0.74

<10

0°F

4-5

F

9.50”

8.90”

1.65” 1.18”

32

PS

277

50182

VEP432PS/L/MV/HE

0.35

97

0.99

0.74

<10

0°F

4-5

F

9.50”

8.90”

1.65” 1.18”

V Item will be discontinued when inventory is depleted.
Case diagrams and wiring diagrams can be found on pages 190-192.

188

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Electronic Fluorescent Ballasts
T8
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F40T8

1

2

3

40

IS

120

50176

EP232IS/120/MC

0.39

45

0.96

1.00

<30

32°F

1-3

F

40

IS

120

50115

EP232IS/H/MV/HE

0.45

54

0.98

1.35

<10

32°F

1-3

F

9.50”

8.90”

1.30” 1.10”

40

IS

277

50115

EP232IS/H/MV/HE

0.20

54

0.97

1.35

<15

32°F

1-3

F

9.50”

8.90”

1.30” 1.10”

40

IS

120

50119

EP232IS/L/MV/HE

0.30

35

0.98

0.90

<10

32°F

1-3

F

9.50”

8.90”

1.30” 1.10”

40

IS

277

50119

EP232IS/L/MV/HE

0.13

35

0.95

0.90

<15

32°F

1-3

F

9.50”

8.90”

1.30” 1.10”

40

IS

120

50123

EP232IS/MV/HE

0.35

44

0.98

1.00

<10

32°F

1-3

F

9.50”

8.90”

1.30” 1.10”

9.50”

8.90”

1.30” 1.00”

40

IS

277

50123

EP232IS/MV/HE

0.16

43

0.97

1.00

<15

32°F

1-3

F

9.50”

8.90”

1.30” 1.10”

40

IS

120

50116

EP232IS/MV/MC

0.38

46

0.98

1.00

<10

32°F

1-3

F

9.50”

8.90”

1.30” 1.10”

40

IS

277

50116

EP232IS/MV/MC

0.16

45

0.97

1.00

<15

32°F

1-3

F

9.50”

8.90”

1.30” 1.10”

40

PS

120

50180

EP232PS/MV/HE

0.38

45

0.98

0.99

<10

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

40

PS

277

50180

EP232PS/MV/HE

0.17

45

0.97

1.01

<10

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

40

PS

120

50178

EP232PS/L/MV/HE

0.32

38

0.99

0.82

<10

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

40

PS

277

50178

EP232PS/L/MV/HE

0.14

39

0.98

0.82

<10

0°F

1-11

F

9.50”

8.90”

1.38” 1.18”

40

IS

120

50121

EP332IS/H/MV/HE

0.84

100

0.98

1.26

<10

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

40

IS

277

50121

EP332IS/H/MV/HE

0.37

98

0.98

1.26

<10

0°F

2-11

F

9.50”

8.90”

1.30” 1.10”

40

IS

120

50168

EP332IS/L/MV/HE

0.60

71

0.98

0.87

<10

32°F

2-11

F

9.50”

8.90”

1.30” 1.10”

40

IS

277

50168

EP332IS/L/MV/HE

0.26

70

0.98

0.87

<15

32°F

2-11

F

9.50”

8.90”

1.30” 1.10”

40

IS

120

50170

EP332IS/MV/HE

0.65

78

0.98

0.95

<10

32°F

2-11

F

9.50”

8.90”

1.30” 1.10”

40

IS

277

50170

EP332IS/MV/HE

0.29

77

0.97

0.95

<15

32°F

2-11

F

9.50”

8.90”

1.30” 1.10”

40

IS

120

50124

EP432IS/120/MC

0.93

112

0.98

0.88

<20

32°F

3-9

F

9.50”

8.90”

1.30” 1.10”

40

IS

120

50172

EP432IS/L/MV/HE

0.82

98

0.98

0.82

<10

32°F

3-9

F

9.50”

8.90”

1.30” 1.10”

40

IS

277

50172

EP432IS/L/MV/HE

0.35

96

0.98

0.82

<10

32°F

3-9

F

9.50”

8.90”

1.30” 1.10”

40

IS

120

50174

EP432IS/MV/HE

0.95

114

0.98

0.96

<10

32°F

3-9

F

9.50”

8.90”

1.30” 1.10”

40

IS

277

50174

EP432IS/MV/HE

0.41

109

0.98

0.96

<10

32°F

3-9

F

9.50”

8.90”

1.30” 1.10”

40

IS

120

50126

EP432IS/MV/MC

0.95

114

0.98

0.92

<10

32°F

3-9

F

9.50”

8.90”

1.30” 1.10”

40

IS

277

50126

EP432IS/MV/MC

0.41

109

0.98

0.92

<10

32°F

3-9

F

9.50”

8.90”

1.30” 1.10”

40

PS

120

50184

EP432PS/MV/HE

0.93

111

0.99

0.88

<10

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

40

PS

277

50184

EP432PS/MV/HE

0.41

111

0.98

0.89

<10

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

40

PS

120

50182

VEP432PS/L/MV/HE

0.83

99

0.99

0.77

<10

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

40

PS

277

50182

VEP432PS/L/MV/HE

0.36

99

0.99

0.79

<10

0°F

3-8

F

9.50”

8.90”

1.65” 1.18”

59

IS

120

50136

EP259IS/MV

0.57

68

0.98

1.04

<10

32°F

1-3

F

9.50”

8.90”

1.30” 1.10”

59

IS

277

50136

EP259IS/MV

0.25

67

0.98

1.04

<10

32°F

1-3

F

9.50”

8.90”

1.30” 1.10”

59

IS

120

50136

EP259IS/MV

0.92

108

0.98

0.83

<10

32°F

2-17

F

9.50”

8.90”

1.30” 1.10”

59

IS

277

50136

EP259IS/MV

0.40

106

0.98

0.83

<10

32°F

2-17

F

9.50”

8.90”

1.30” 1.10”

F96T8
1
2

V Item will be discontinued when inventory is depleted.
Case diagrams and wiring diagrams can be found on pages 190-192.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 189

ELECTRONIC FLUORESCENT BALLASTS
T8
Case Diagram

M

H
L

F

W

Wiring Diagrams

LAMP
RED
BLACK
WHITE

BALLAST

1-3

BLUE
BLUE
1-11

LAMP

LAMP

RED
LINE

1-12

190

TOC

BLACK

BALLAST

LINE

BLUE
BLUE
BLACK
WHITE

BALLAST

RED
RED

WHITE

1-18

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Electronic Fluorescent Ballasts
T8
Wiring Diagrams

LAMP 2

LAMP

LAMP 1

RED
BLACK
WHITE

BALLAST

BLUE

1-23

BLACK

LINE

WHITE

2-11

LAMP 2

LINE

RED
BLUE
BLUE
BLUE

BALLAST

BLUE
BLUE
BLACK
WHITE
BLUE
BLUE

LAMP 2

RED
RED

LAMP 1

BALLAST
RED
RED

RED
BLACK
WHITE

LAMP 1
2-12

BALLAST

BLUE
BLUE

2-17

LAMP 3

LAMP 2

LAMP 2

LAMP 1

LAMP 1
RED
BLACK
WHITE

2-24

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

BALLAST

BLUE
BLUE
BLUE

3-7

TOC 191

ELECTRONIC FLUORESCENT BALLASTS
T8
Wiring Diagrams

LAMP 3

LAMP 3

LAMP 2

LAMP 2

LAMP 1

LAMP 1
YELLOW
YELLOW
LINE

RED
RED
BLUE
BLUE
RED/WHITE
RED/WHITE
BLUE/WHITE
BLUE/WHITE

BALLAST

BLACK
WHITE

3-8

LINE

BLACK
WHITE

3-9

LAMP 4

LAMP 4

LAMP 3

LAMP 3

LAMP 2

LAMP 2

LAMP 1

LAMP 1
YELLOW
YELLOW
LINE

BLACK
WHITE

RED
RED
BLUE
BLUE
RED/WHITE
RED/WHITE
BLUE/WHITE
BLUE/WHITE

BALLAST

BLACK
WHITE

BALLAST

YELLOW
YELLOW
BLUE
BLUE
RED
RED

4-6

4-5

192

BALLAST

YELLOW
YELLOW
BLUE
BLUE
RED
RED

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Electronic Fluorescent Ballasts
T9 Circline
Lamp Type

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

E1CR22RS/120/PT

0.33

21

0.52

0.90

<150

0°F

1-4

H

3.45”

3.12”

1.81” 1.21”

52106

EP2CF26PS/MV/DC/K

0.34

43

0.99

1.00

<10

0°F

1-13

L

5.00”

4.63”

2.40” 1.00”

52106

EP2CF26PS/MV/DC/K

0.15

43

0.99

1.00

<10

0°F

1-13

L

5.00”

4.63”

2.40” 1.00”

*E2CR72RS/120/PT

0.60

40

0.54

0.76

<150

0°F

2-3

F

6.46”

6.00”

1.89” 1.00”

*E2CR72RS/120/PT

0.75

50

0.53

0.70

<150

0°F

2-3

F

6.46”

6.00”

1.89” 1.00”

Product
Number

RS

120

50150

40

PS

120

40

PS

277

Qty. Watts

Case Dimensions

Line
Current
(Amps)

Input
Volts

Start
Type

Product Code

Length Mounting Width Height

FC8T9
1

22

FC16T9
1

FC8T9 + FC12T9
2 22+32

RS

120

50148

FC12T9 + FC16T9
2 32+40

RS

120

50148

*Ballast operates two different lamps together.
Case diagrams and wiring diagrams can be found on pages 193-194.

Case Diagrams

M

H
L
W

F

H
M

W

L

H

H
M
W

L

L

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 193

ELECTRONIC FLUORESCENT BALLASTS
T9 Circline
Wiring Diagrams

FOR POSITIVE STARTING,
SPACE 3 METAL CLIPS 120º
APART AS ILLUSTRATED.

BLACK
WHITE

LINE

BALLAST

BLUE
BLUE
RED
RED

1-4

GREEN

BALLAST

BLACK
WHITE

RED
RED
YEL
YEL
BLUE
BLUE

1-13

LINE

2-3

194

TOC

BLUE
BLUE
RED
RED
BLACK
WHITE

BALLAST

BLUE
BLUE
RED
RED

FOR POSITIVE STARTING,
SPACE 3 METAL CLIPS 120º
APART AS ILLUSTRATED.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Electronic Fluorescent Ballasts
T12
Lamp Type
Start
Type

Qty. Watts

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F14T12
1

14

RS

120

50108

VE120RS/120

0.24

15.5

0.54

1.00

<150

0°F

1-18

F

6.46”

6.00”

1.37” 1.00”

2

14

RS

120

50110

E220RS/120

0.42

27

0.54

0.85

<150

0°F

2-12

F

6.46”

6.00”

1.37” 1.00”

F15T12
1

15

RS

120

50108

VE120RS/120

0.25

16

0.54

1.00

<140

0°F

1-18

F

6.46”

6.00”

1.37” 1.00”

2

15

RS

120

50110

E220RS/120

0.48

32

0.56

1.02

<150

0°F

2-12

F

6.46”

6.00”

1.37” 1.00”

F20T12
1

20

RS

120

50108

VE120RS/120

0.26

18

0.56

0.90

<130

0°F

1-18

F

6.46”

6.00”

1.37” 1.00”

2

20

RS

120

50110

E220RS/120

0.52

36

0.57

0.87

<130

0°F

2-12

F

6.46”

6.00”

1.37” 1.00”

F25T12/48”
1

2

25

RS

120

50128

EP240RS/120

0.43

51

0.99

1.70

<10

0°F

1-11

F

9.50”

8.90”

1.70” 1.15”

25

RS

120

50160

EP240RS/MV

0.43

51

0.99

1.70

<10

0°F

1-11

F

9.50”

8.90”

1.70” 1.15”

25

RS

277

50160

EP240RS/MV

0.19

51

0.99

1.70

<10

0°F

1-11

F

9.50”

8.90”

1.70” 1.15”

25

RS

120

50128

EP240RS/120

0.66

78

0.99

1.40

<10

0°F

2-1

F

9.50”

8.90”

1.70” 1.15”

25

RS

120

50160

EP240RS/MV

0.66

78

0.99

1.40

<10

0°F

2-1

F

9.50”

8.90”

1.70” 1.15”

25

RS

277

50160

EP240RS/MV

0.28

78

0.98

1.40

<10

0°F

2-1

F

9.50”

8.90”

1.70” 1.15”

30

RS

120

50128

EP240RS/120

0.32

38

0.98

1.00

<10

0°F

1-11

F

9.50”

8.90”

1.70” 1.15”

30

RS

120

50160

EP240RS/MV

0.32

38

0.99

1.00

<10

0°F

1-11

F

9.50”

8.90”

1.70” 1.15”

30

RS

277

50160

EP240RS/MV

0.14

38

0.99

1.00

<10

0°F

1-11

F

9.50”

8.90”

1.70” 1.15”

30

RS

120

50128

EP240RS/120

0.49

58

0.99

0.88

<10

0°F

2-1

F

9.50”

8.90”

1.70” 1.15”

30

RS

120

50160

EP240RS/MV

0.49

58

0.99

0.88

<10

0°F

2-1

F

9.50”

8.90”

1.70” 1.15”

30

RS

277

50160

EP240RS/MV

0.22

58

0.97

0.88

<10

0°F

2-1

F

9.50”

8.90”

1.70” 1.15”

F30T12
1

2

F34T12, FB34
1

2

34

RS

120

50128

EP240RS/120

0.34

40

0.98

1.10

<10

0°F

1-11

F

9.50”

8.90”

1.70” 1.15”

34

RS

120

50160

EP240RS/MV

0.34

40

0.98

1.10

<10

0°F

1-11

F

9.50”

8.90”

1.70” 1.15”

34

RS

277

50160

EP240RS/MV

0.15

40

0.98

1.10

<10

0°F

1-11

F

9.50”

8.90”

1.70” 1.15”

34

RS

120

50128

EP240RS/120

0.53

63

0.98

0.85

<10

0°F

2-1

F

9.50”

8.90”

1.70” 1.15”

34

RS

120

50160

EP240RS/MV

0.53

63

0.98

0.85

<10

0°F

2-1

F

9.50”

8.90”

1.70” 1.15”

34

RS

277

50160

EP240RS/MV

0.23

63

0.98

0.85

<10

0°F

2-1

F

9.50”

8.90”

1.70” 1.15”

F40T12, FB40
1

2

40

RS

120

50128

EP240RS/120

0.40

47

0.99

1.10

<10

0°F

1-11

F

9.50”

8.90”

1.70” 1.15”

40

RS

120

50160

EP240RS/MV

0.40

47

0.99

1.10

<10

0°F

1-11

F

9.50”

8.90”

1.70” 1.15”

40

RS

277

50160

EP240RS/MV

0.17

47

0.99

1.10

<10

0°F

1-11

F

9.50”

8.90”

1.70” 1.15”

40

RS

120

50128

EP240RS/120

0.62

74

0.99

0.88

<10

0°F

2-1

F

9.50”

8.90”

1.70” 1.15”

40

RS

120

50160

EP240RS/MV

0.62

74

0.99

0.88

<10

0°F

2-1

F

9.50”

8.90”

1.70” 1.15”

40

RS

277

50160

EP240RS/MV

0.27

74

0.99

0.88

<10

0°F

2-1

F

9.50”

8.90”

1.70” 1.15”

V Item will be discontinued when inventory is depleted.
Case diagrams and wiring diagrams can be found on pages 197-199.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 195

Electronic Fluorescent Ballasts
T12
Lamp Type
Qty. Watts

Start
Type

Case Dimensions

Input
Volts

Product
Number

Product Code

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F48T12/ES
2

30

IS

120

50130

EP275IS/MV

0.60

64

0.95

0.92

<12

60°F

2-4

D

11.70” 11.00”

3.15” 1.85”

30

IS

277

50130

EP275IS/MV

0.26

64

0.95

0.92

<12

60°F

2-4

D

11.70” 11.00”

3.15” 1.85”

40

IS

120

50132

EP260IS/120

0.62

74

0.98

0.92

<12

0°F

2-4

F

9.50”

8.90”

1.70” 1.15”

40

IS

277

50134

EP260IS/277

0.27

74

0.98

0.92

<12

0°F

2-4

F

9.50”

8.90”

1.70” 1.15”

40

IS

120

50130

EP275IS/MV

0.68

76

0.95

0.92

<10

0°F

2-4

D

11.70” 11.00”

3.15” 1.85”

40

IS

277

50130

EP275IS/MV

0.30

76

0.95

0.92

<10

0°F

2-4

D

11.70” 11.00”

3.15” 1.85”

F48T12
2

F48T12/HO
2

60

RS

120

50162

EP2110RS/120

0.88

104

0.99

0.90

<10

-20°F

2-1

A

11.80” 11.00”

2.15” 1.61”

60

RS

120

50164

EP2110RS/MV

0.88

104

0.99

0.90

<20

-20°F

2-1

A

11.80” 11.00”

2.15” 1.61”

60

RS

277

50164

EP2110RS/MV

0.38

104

0.95

0.90

<20

-20°F

2-1

A

11.80” 11.00”

2.15” 1.61”

F60T12/HO
2

75

RS

120

50162

EP2110RS/120

1.10

132

0.99

0.90

<10

-20°F

2-1

A

11.80” 11.00”

2.15” 1.61”

75

RS

120

50164

EP2110RS/MV

1.10

132

0.99

0.90

<10

-20°F

2-1

A

11.80” 11.00”

2.15” 1.61”

75

RS

277

50164

EP2110RS/MV

0.48

132

0.96

0.90

<10

-20°F

2-1

A

11.80” 11.00”

2.15” 1.61”

57

IS

120

50130

EP275IS/MV

0.60

67

0.95

1.05

<12

0°F

1-12

D

11.70” 11.00”

3.15” 1.85”

57

IS

277

50130

EP275IS/MV

0.26

67

0.95

1.05

<12

0°F

1-12

D

11.70” 11.00”

3.15” 1.85”

57

IS

120

50132

EP260IS/120

0.90

106

0.98

0.95

<12

0°F

2-4

F

9.50”

8.90”

1.70” 1.15”

57

IS

277

50134

EP260IS/277

0.39

106

0.98

0.95

<12

0°F

2-4

F

9.50”

8.90”

1.70” 1.15”

57

IS

120

50130

EP275IS/MV

0.92

107

0.95

0.95

<12

0°F

2-4

D

11.70” 11.00”

3.15” 1.85”

57

IS

277

50130

EP275IS/MV

0.40

107

0.95

0.95

<12

0°F

2-4

D

11.70” 11.00”

3.15” 1.85”

F72T12
1

2

F72T12/HO
2

85

RS

120

50162

EP2110RS/120

1.30

154

0.99

0.90

<10

-20°F

2-1

A

11.80” 11.00”

2.15” 1.61”

85

RS

120

50164

EP2110RS/MV

1.30

154

0.99

0.90

<20

-20°F

2-1

A

11.80” 11.00”

2.15” 1.61”

85

RS

277

50164

EP2110RS/MV

0.56

154

0.97

0.90

<20

-20°F

2-1

A

11.80” 11.00”

2.15” 1.61”

71

0.98

1.12

<12

60°F

1-12

D

11.70” 11.00”

3.15” 1.85”

F96T12/ES
1

2

60

IS

120

50130

EP275IS/MV

0.60

60

IS

277

50130

EP275IS/MV

0.27

72

0.98

1.12

<12

60°F

1-12

D

11.70” 11.00”

3.15” 1.85”

60

IS

120

50132

EP260IS/120

0.97

115

0.98

0.95

<12

60°F

2-4

F

9.50”

8.90”

1.70” 1.15”

60

IS

277

50134

EP260IS/277

0.42

115

0.98

0.95

<12

60°F

2-4

F

9.50”

8.90”

1.70” 1.15”

60

IS

120

50130

EP275IS/MV

0.97

115

0.99

0.95

<10

60°F

2-4

D

11.70” 11.00”

3.15” 1.85”

60

IS

277

50130

EP275IS/MV

0.42

115

0.98

0.95

<10

60°F

2-4

D

11.70” 11.00”

3.15” 1.85”

Case diagrams and wiring diagrams can be found on pages 197-199.

196

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

ELECTRONIC FLUORESCENT BALLASTS
T12
Lamp Type
Start
Type

Qty. Watts

Case Dimensions

Input
Volts

Product
Number

Product Code

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

F96T12
1
2

75

IS

120

50130

EP275IS/MV

0.69

83

0.99

1.05

<12

0°F

1-12

D

75

IS

277

50130

EP275IS/MV

0.31

83

0.98

1.05

<12

0°F

1-12

D

11.70” 11.00”

3.11” 1.85”

75

IS

120

50130

EP275IS/MV

1.15

133

0.99

0.86

<12

0°F

2-4

D

11.70” 11.00”

3.11” 1.85”

75

IS

277

50130

EP275IS/MV

0.49

133

0.99

0.86

<12

0°F

2-4

D

11.70” 11.00”

3.11” 1.85”

11.70” 11.00”

3.11” 1.85”

F96T12/HO/ES
2

95

RS

120

50162

EP2110RS/120

1.38

164

0.99

0.90

<10

60°F

2-1

A

11.80” 11.00”

2.15” 1.61”

95

RS

120

50164

EP2110RS/MV

1.38

164

0.98

0.90

<20

60°F

2-1

A

11.80” 11.00”

2.15” 1.61”

95

RS

277

50164

EP2110RS/MV

0.60

164

0.97

0.90

<20

60°F

2-1

A

11.80” 11.00”

2.15” 1.61”

F96T12/HO
1

2

110

RS

120

50162

EP2110RS/120

0.88

104

0.99

0.92

<15

-20°F

1-7

A

11.80” 11.00”

2.15” 1.61”

110

RS

120

50164

EP2110RS/MV

0.88

104

0.99

0.92

<20

-20°F

1-7

A

11.80” 11.00”

2.15” 1.61”

110

RS

277

50164

EP2110RS/MV

0.38

104

0.95

0.92

<20

-20°F

1-7

A

11.80” 11.00”

2.15” 1.61”

110

RS

120

50162

EP2110RS/120

1.65

196

0.99

0.90

<10

-20°F

2-1

A

11.80” 11.00”

2.15” 1.61”

110

RS

120

50164

EP2110RS/MV

1.65

196

0.99

0.90

<10

-20°F

2-1

A

11.80” 11.00”

2.15” 1.61”

110

RS

277

50164

EP2110RS/MV

0.71

196

0.98

0.90

<10

-20°F

2-1

A

11.80” 11.00”

2.15” 1.61”

Case diagrams and wiring diagrams can be found on pages 197-199.

Case Diagrams

H

W

A

D

M
L

M

H
L

F

W

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 197

ELECTRONIC FLUORESCENT BALLASTS
T12
Wiring Diagrams

LAMP

LINE

BLACK
WHITE

BALLAST

1-7

RED
RED
BLUE
BLUE
1-11

LAMP

RED
LINE

1-12

198

TOC

BLACK

BALLAST

LAMP

LINE

WHITE

BLUE
BLUE
BLACK
WHITE

BALLAST

RED
RED

1-18

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

ELECTRONIC FLUORESCENT BALLASTS
T12
Wiring Diagrams

LAMP 2

LAMP 2

LAMP 1

LAMP 1

LINE

RED
BLACK

BALLAST

BLUE
BLUE

WHITE

2-4

2-1

LAMP 2

LINE

BLUE
BLUE
BLACK
WHITE
BLUE
BLUE

RED
RED

BALLAST
RED
RED

LAMP 1
2-12

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 199

ELECTRONIC FLUORESCENT BALLASTS
Cross Reference Guide
HALCO

ADVANCE

UNIVERSAL/
MAGNETEK

HOWARD

E114RS/120

-

-

-

E120RS/120

-

-

-

E220RS/120

-

-

-

EP2110RS/120

-

B295SR120HP

E2/110RS-120

EP2110RS/MV

ICN-2S110-SC

B295SRUNVHP

EP2/110RS-MV

EP228PS/MV/MC

ICN-2S28-N

B228PUNV-N

EP2/28T5/PRS/MV

EP132IS/MV/MC

ICN-1P32-N

B132IUNVHP-N

-

E232IS/120/R/MC

REB-2P32-SC

B232I120RES-G

E2/32IS-120MC

EP232IS/120/MC

-

B232I120RH-A

EP2/32IS-120MC

EP232IS/MV/MC

ICN-2P32-N

B232IUNVHP-N

EP2/32IS/MV/MC

EP232IS/H/MV/HE

IOPA-2P32-HL-N

B232IUNVHEH-A

EPH2/32IS/MV/MC/HE

EP232IS/L/MV/HE

IOPA-2P32-LW-N

B232IUNVEL-A

EPL2/32IS/MV/MC/HE

EP232IS/MV/HE

IOPA-2P32-N

B232IUNVHE-A

EP2/32IS/MV/MC/HE

EP232PS/MV/HE

IOP-2PSP32-SC

B232PUNVHE-B

EP2/PRS/MV/MC/HE

EP232PS/L/MV/HE

IOP-2PSP32-LW-SC

B232PUNVEL-B

-

EP239HO/PS/MV

ICN-2S39

B239PUNV-D

EP2/39HO/PRS/MV

EP240RS/120

RELB-2S40-N

B240R120HP

E2/40RS-120MC

EP240RS/MV

ICN-2S40-N

-

EP2/40RS/MV/MC

EP254HO/PS/MV

ICN-2S54

B254PUNV-D

EP2/54HO/PRS/MV/90CW

EP254HO/PS/MV/MC

ICN-2S54-N

-

EP2/54HO/PRS/MV/W/MC

EP259IS/MV

IOP-2P59-SC

B259IUNVHP-A

EP2/59IS/MV/MC

EP260IS/120

-

B260I120M-A

-

EP260IS/277

-

-

-

EP275IS/MV

ICN-2P60-SC

B260IUNVHP

EP2/75IS/MV/SC

EP332IS/MV/MC

ICN-3P32-N

B332IUNVHP-A

-

EP332IS/H/MV/HE

IOPA-3P32-HL-N

B332IUNVHEH-A

-

EP332IS/L/MV/HE

IOPA-3P32-LW-N

B332IUNVEL-A

EPL3/32IS/MV/SC/HE

EP332IS/MV/HE

IOPA-3P32-N

B332IUNVHE-A

EP3/32IS/MV/MC/HE

E432IS/120/R/SL

REB-4P32-SC

B432I120RES-A

-

EP432IS/120/SL

-

B432I120RH-A

-

EP432IS/MV/MC

ICN-4P32-N

B432IUNVHP-A

-

EP432IS/L/MV/HE

IOPA-4P32-LW-N

B432IUNVEL-A

EPL4/32IS/MV/MC/HE

EP432IS/MV/HE

IOPA-4P32-N

B432IUNVHE-A

EP4/32IS/MV/MC/HE

EP432PS/MV/HE

IOP-4PSP32-SC

B432PUNVHE-A

EP4/32PPRS/MV/SC/HE

EP432PS/L/MV/HE

IOP-4PSP32LW-SC

B432PUNVEL-A

-

EP454HO/PS/MV

IOP-4PSP54-2LS-G

B454PUNV-E

-

E1CR22RS/120/PT

-

-

-

E2CR72RS/120/PT

-

-

-

200

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Electronic Fluorescent Ballasts
Specifications

SPECIFICATIONS
Ballast shall have a Lamp Current Crest Factor of <1.7 in accordance with ANSI C82.1.
Ballast shall withstand line voltage transients and surges as specified in ANSI standard
C62.41-1991.
Ballast shall have an Underwriters Laboratories certification for operation in the US and
either an Underwriters Laboratories or Canadian Standards Association certification for
operation in Canada.
Ballast shall comply with the EMI and RFI limits of the code of Federal Regulations, Title 47,
Part 18C for Non-Consumer equipment.
Ballast shall operate in the range of 50-60Hz input frequency.
Ballast shall operate at a maximum of 18 feet remote mounting distance for primary lamp.
For energy saving reduced wattages lamps, remote mounting distances will be shorter.
Ballast shall operate at a frequency of 20-40 kHz.
Ballast shall contain potting compound in order to protect from moisture, dissipate heat and
provide stability.
All ProFormance ballasts shall have a power factor of 0.98 or better on the primary lamp
configuration.
Ballast shall be sound rated Class A.
Ballast shall have a minimum starting temperature of 0˚F standard lamps and 60°F on
Energy Saving lamps.
Ballast shall tolerate sustained variations of +/-10% of supply voltage with
no damage to the ballast.
Ballast shall not contain PCBs.
Manufacturer shall provide written warranty against defects in material or workmanship
for 5 years from date of manufacture.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 201

Electronic Fluorescent Ballast
Lamp Compatibility Specifications
E114RS/120
50104
Lamp Type

E120RS/120
50108
# of
Lamps

Lamp Type

E154HO/RS/120
50140

E220RS/120
50110

# of
Lamps

Lamp Type

# of
Lamps

Lamp Type

# of
Lamps

F14T5

1

F20T12

1

F54T5/HO

1

F20T12

2

F6T5

2

F20T8

1

PLL55/RS/2G11

1

F20T8

2

F8T5

2

F18T8 24"

1

F18T8 24"

2

F13T5

1

F17T8

1

F17T8

2

F21T5

1

F15T12

1

F15T12

2

PL13D/E/G24q

1

F15T8

1

F15T8

2

PL13T/E/G24q

1

F14T12

1

F14T12

2

F14T8

1

F14T8

2

E232IS/120/R/MC
50118
Lamp Type

E432IS/120/R/SL
50158
# of
Lamps

Lamp Type

EP132IS/MV/MC
50112
# of
Lamps

Lamp Type

EP2110RS/120
50162
# of
Lamps

Lamp Type

# of
Lamps

1, 2

F32T8

1, 2

F32T8

3, 4

F32T8

1

F96T12/HO

F25T8

1, 2

F28T8

3, 4

F28T8

1

F96T12/HO/ES

2

F17T8

1, 2

F25T8

3, 4

F25T8

1

F72T12/HO

2

F40T8

1

F17T8

3, 4

F17T8

1

F60T12/HO

2

F40T8

1

F48T12/HO

2

EP2110RS/MV
50164

EP228PS/MV/MC
52112

EP232IS/120/MC
50176

Lamp Type

# of
Lamps

F96T12/HO

1, 2

F35T5

1, 2

F32T8

1, 2

F96T12/HO/ES

2

F28T5

1, 2

F25T8

1, 2

F72T12/HO

2

F21T5

1, 2

F17T8

1, 2

F60T12/HO

2

F14T5

1, 2

F40T8

1

F48T12/HO

2

202

TOC

Lamp Type

# of
Lamps

Lamp Type

# of
Lamps

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Electronic Fluorescent Ballast
Lamp Compatibility Specifications
EP232IS/H/MV/HE
50115
Lamp Type

EP232IS/L/MV/HE
50119
# of
Lamps

Lamp Type

EP232IS/MV/HE
50123
# of
Lamps

Lamp Type

EP232IS/MV/MC
50116
# of
Lamps

Lamp Type

# of
Lamps

F32T8

1, 2

F32T8

1, 2

F32T8

1, 2

F32T8

1, 2

F28T8

1, 2

F28T8

1, 2

F28T8

1, 2

F28T8

1, 2

F28T8/ES

1,2

F25T8/ES

1, 2

F25T8/ES

1, 2

F25T8

1, 2

F25T8

1, 2

F25T8

1, 2

F25T8

1, 2

F17T8

1, 2

F17T8

1, 2

F17T8

1, 2

F17T8

1, 2

F40T8

1

F40T8

1

F40T8

1

F40T8

1

EP232PS/L/MV/HE
50178
Lamp Type

EP232PS/MV/HE
50180
# of
Lamps

Lamp Type

EP239HO/PS/MV
50142

EP240RS/120
50128

# of
Lamps

Lamp Type

# of
Lamps

Lamp Type

# of
Lamps

F32T8

1, 2

F32T8

1, 2

F39T5/HO

1, 2

F40T12

1, 2

F28T8

1, 2

F28T8

1, 2

F24T5/HO

1, 2

F34T12

1, 2

F25T8/ES

1, 2

F25T8/ES

1, 2

PLL40/2G11

1, 2

F25T12/48"

1, 2

F25T8

1, 2

F25T8

1, 2

PLL36/2G11

1, 2

F30T12

1, 2

F17T8

1, 2

F17T8

1, 2

PLL24/2G11

1, 2

F40T8

1

F40T8

1

FC40T5

1, 2

FC22T5

1, 2

FC22T5 + FC40T5

EP240RS/MV
50160

EP254HO/PS/MV
50144

2

EP254HO/PS/MV/MC
52114

EP259IS/MV
50136

# of
Lamps

Lamp Type

# of
Lamps

Lamp Type

# of
Lamps

F40T12

1, 2

F54T5/HO

1, 2

F54T5/HO

1, 2

F34T12

1, 2

PLL55/2G11

1, 2

F49T5/HO

1, 2

F25T12/48”

1, 2

PLL50/2G11

1, 2

PLL55/2611

1, 2

F30T12

1, 2

FC55T5/HO

1, 2

PLL50/2611

1, 2

Lamp Type

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Lamp Type

F96T8

# of
Lamps

1, 2

TOC 203

Electronic Fluorescent Ballast
Lamp Compatibility Specifications
EP260IS/120
50132

EP260IS/277
50134

EP275IS/MV
50130

Lamp Type

# of
Lamps

Lamp Type

# of
Lamps

F96T12/ES

2

F96T12/ES

2

F96T12

1, 2

F72T12

2

F72T12

2

F96T12/ES

1, 2

F48T12

2

F48T12

2

F72T12

1, 2

F96T12/HO

1

F96T12/HO

1

F48T12

1, 2

F48T12/ES

1, 2

EP332IS/H/MV/SL
50121
Lamp Type

EP332IS/L/MV/HE
50168
# of
Lamps

Lamp Type

Lamp Type

# of
Lamps

EP332IS/MV/HE
50170
# of
Lamps

Lamp Type

# of
Lamps

F32T8

2, 3

F32T8

2, 3

F32T8

2, 3

F28T8

2, 3

F28T8

2, 3

F28T8

2, 3

F25T8/ES

2, 3

F25T8/ES

2, 3

F25T8/ES

2, 3

F25T8

2, 3

F25T8

2, 3

F25T8

2, 3

F17T8

2, 3

F17T8

2, 3

F17T8

2, 3

F40T8

2

F40T8

2

F40T8

2

EP332IS/MV/MC
50122
Lamp Type

# of
Lamps

F32T8

2, 3

F28T8

2, 3

F25T8

2, 3

F17T8

2, 3

F40T8

2, 3

204

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Electronic Fluorescent Ballast
Lamp Compatibility Specifications
EP432IS/120/SL
50124
Lamp Type

EP432IS/L/MV/HE
50172
# of
Lamps

Lamp Type

EP432IS/MV/HE
50174
# of
Lamps

Lamp Type

EP432IS/MV/MC
50126
# of
Lamps

# of
Lamps

Lamp Type

F32T8

3, 4

F32T8

3, 4

F32T8

3, 4

F32T8

3, 4

F28T8

3, 4

F28T8

3, 4

F28T8

3, 4

F28T8

3, 4

F25T8

3, 4

F25T8/ES

3, 4

F25T8/ES

3, 4

F25T8

3, 4

F17T8

3, 4

F25T8

3, 4

F25T8

3, 4

F17T8

3, 4

F40T8

3

F17T8

3, 4

F17T8

3, 4

F40T8

3

PLL40/2G11

3

F40T8

3

F40T8

3

PLL40/2G11

3

EP432PS/L/MV/HE
50182
Lamp Type

EP432PS/MV/HE
50184
# of
Lamps

Lamp Type

E1CR22RS/120/PT
50150

EP454HO/PS/MV
50186
# of
Lamps

Lamp Type

# of
Lamps

F32T8

3, 4

F32T8

3, 4

F54T5/HO

1, 2, 3, 4

F28T8

3, 4

F28T8

3, 4

F49T5/HO

2, 3, 4

F25T8/ES

3, 4

F25T8/ES

3, 4

PLL50/2G11

F25T8

3, 4

F25T8

3, 4

F17T8

3, 4

F17T8

3, 4

F40T8

3

F40T8

3

E1CR32RS/120/PT
50146
Lamp Type

Lamp Type

FC8T9

# of
Lamps

1

3, 4

E2CR72RS/120/PT
50148
# of
Lamps

Lamp Type

# of
Lamps

FC12T9

1

FC12T9 + FC16T9

2

FC9T9/30W

1

FC8T9 + FC12T9

2

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 205

®

ELECTRONIC SIGN BALLASTS
CONTENTS
208 How To Read a Table
209 T8/HO Sign Ballasts
209 T12/HO Sign Ballasts
210 Case Dimensions and Wiring Diagrams
211 Cross Reference Guide
211 Lamp Compatibility Specifications

main
TOC

HOW TO READ AN ELECTRONIC SIGN
BALLAST TABLE

PRODUCT CODE

OPEN
CIRCUIT
VOLTS

Abbreviated product description
can also be used for ordering.

NUMBER OF LAMPS

Specifies the number of lamps the
ballast will operate.

The voltage required
to start a lamp, which
is provided by a
ballast to the lamp’s
electrodes.

INPUT
VOLTS

WIRING
DIAGRAM

References the wiring
diagram to use.

CASE
DIAGRAM

Representation
of the ballast‘s
case.

MAX LINE
CURRENT

Voltage required
from a power
supply for
proper ballast
operation.

The current that
results when the
line voltage is
applied to a load.

Lamp Data
Number of
lamps

Lamp
Footage

Input Volts

Product
Number

Product Code

Max Line
Max Input
Open
Min Starting
Current (Amps) Power (Watts) Circuit Volts
Temp

Wiring Diag.

Case
Diagram

Weight
(Ibs.)

Min

Max

1, 2

4’

12’

120

57114

ESB/0216/12

1.10

122

800

-20°F

1-3, 2-17

D2

2.88

1, 2

4’

12’

277

57114

ESB/0216/12

0.45

121

800

-20°F

1-3, 2-17

D2

2.88

1, 2, 3, 4

4’

24’

120

57116

ESB/0432/14

2.20

244

800

-20°F

1-17, 2-19, 3-6, 4-3

D3

4.46

1, 2, 3, 4

4’

24’

277

57116

ESB/0432/14

0.90

242

800

-20°F

1-17, 2-19, 3-6, 4-3

D3

4.46

T8/HO

LAMP
FOOTAGE
(Min/Max)
LAMP TYPE

Indicates the type
of lamp that the
ballast will operate.

Specifies the
minimum and
maximum total
lamp length per
ballast.

MAX INPUT
POWER

Total power input
to the ballast
which includes
lamp watts and
ballast losses.

PRODUCT
NUMBER

Use this number when
placing an order.

TOC

WEIGHT
(lbs.)
MIN STARTING TEMP.

References minimum ambient
temperature that the ballast will
reliably start a lamp.

Indicates the
ballast’s weight.

Electronic sign Ballasts
T8/T12 High Output

Number of Lamps Per
Ballast

T8 Footage Chart
2

4

Total Lamp Footage
6

8

10

12

14

16

20

22

24

26

28

30

32

34

36

38

40

42

44

46

48

30

32

34

36

38

40

42

44

46

48

ESB/0216/12

1, 2

ESB/0432/14

1, 2, 3, 4

ESB/1040/14

1, 2, 3, 4

ESB/0848/46

4, 5, 6

Total Lamp Footage

T12 Footage Chart
Number of Lamps Per
Ballast

18

2

4

6

8

10

12

14

16

18

20

22

24

26

28

ESB/0216/12

1, 2

ESB/0432/14

1, 2, 3, 4

ESB/1040/14

1, 2, 3, 4

ESB/0848/46

4, 5, 6

Lamp Data
Number of
lamps

Lamp
Footage

Input
Volts

Product
Number

Product Code

Max Line
Max Input
Open
Min Starting
Current (Amps) Power (Watts) Circuit Volts
Temp

Wiring Diagrams

Case
Diagram

Weight
(Ibs.)

Min

Max

1, 2

4’

12’

120

57114

ESB/0216/12

1.10

122

800

-20°F

1-3, 2-17

D2

2.88

1, 2

4’

12’

277

57114

ESB/0216/12

0.45

121

800

-20°F

1-3, 2-17

D2

2.88

1, 2, 3, 4

4’

24’

120

57116

ESB/0432/14

2.20

244

800

-20°F

1-17, 2-19, 3-6, 4-3

D3

4.46

1, 2, 3, 4

4’

24’

277

57116

ESB/0432/14

0.90

242

800

-20°F

1-17, 2-19, 3-6, 4-3

D3

4.46

1, 2, 3, 4

8’

32’

120

57118

ESB/1040/14

2.80

330

1000

-20°F

1-16, 2-18, 3-5, 4-2

D4

7.00

1, 2, 3, 4

8’

32’

277

57118

ESB/1040/14

1.25

325

1000

-20°F

1-16, 2-18, 3-5, 4-2

D4

7.00

4, 5, 6

16’

36’

120

57120

ESB/0848/46

3.30

370

860

-20°F

4-4, 5-1, 6-1

D4

7.02

4, 5, 6

16’

36’

277

57120

ESB/0848/46

1.36

365

860

-20°F

4-4, 5-1, 6-1

D4

7.02

1, 2

2’

16’

120

57114

ESB/0216/12

1.20

131

800

-20°F

1-3, 2-17

D2

2.88

1, 2

2’

16’

277

57114

ESB/0216/12

0.50

132

800

-20°F

1-3, 2-17

D2

2.88

1, 2, 3, 4

4’

32’

120

57116

ESB/0432/14

2.40

267

800

-20°F

1-17, 2-19, 3-6, 4-3

D3

4.46

1, 2, 3, 4

4’

32’

277

57116

ESB/0432/14

1.00

267

800

-20°F

1-17, 2-19, 3-6, 4-3

D3

4.46

1, 2, 3, 4

10’

40’

120

57118

ESB/1040/14

3.00

352

1000

-20°F

1-16, 2-18, 3-5, 4-2

D4

7.00

1, 2, 3, 4

10’

40’

277

57118

ESB/1040/14

1.30

349

1000

-20°F

1-16, 2-18, 3-5, 4-2

D4

7.00

4, 5, 6

8’

48’

120

57120

ESB/0848/46

3.50

410

860

-20°F

4-4, 5-1, 6-1

D4

7.02

4, 5, 6

8’

48’

277

57120

ESB/0848/46

1.50

405

860

-20°F

4-4, 5-1, 6-1

D4

7.02

T8/HO

T12/HO

See following page for case dimensions and wiring diagrams.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 209

ELECTRONIC SIGN BALLASTS
T8/T12 High Output
Case Dimensions

Case Diagram

Drawing #

Overall (L)

Width (W)

Height (H)

Mounting (M)

D2

9.50”

2.36”

1.70”

8.90”

D3

11.65”

3.15”

1.85”

11.00”

D4

14.45”

3.23”

2.20”

13.75”

H
M

Wiring Diagrams

L

W
LAMP
RED
BLACK
WHITE

BALLAST

BLUE
BLUE

1-3

BALLAST

BLACK
WHITE

YELLOW
YELLOW
/ BLACK
BLACK

YELLOW
/ BLACK
YELLOW
BLUE
BLUE
RED
RED

1-16

BALLAST

WHITE

LAMP 1

LAMP 2

LAMP 1

LAMP 1

BALLAST

WHITE

2-18

YELLOW
YELLOW
/ BLACK
BLACK
WHITE

TOC

LAMP 1
BLUE
BLUE
RED
RED

BLACK
WHITE

BALLAST

YELLOW
/ BLACK
YELLOW
BLUE
BLUE
RED
RED

LAMP 4

LAMP 2

LAMP 3

LAMP 3

LAMP 2

LAMP 2

LAMP 1

LAMP 1

BLUE
BLUE
RED
RED

BLACK
WHITE

BALLAST

WHITE

LAMP 5

LAMP 3

LAMP 4

LAMP 2

LAMP 3

LAMP 5
LAMP 4
LAMP 3
LAMP 2

LAMP 1

BLACK
WHITE

5-1

BLUE
BLUE
RED
RED

LAMP 6

LAMP 2

YELLOW
/ BLACK
YELLOW
BLUE
BLUE
BLUE
RED
RED
RED

BALLAST

4-3

LAMP 4

BALLAST

YELLOW
YELLOW
/ BLACK
BLACK

YELLOW
/ BLACK
YELLOW
BLUE
BLUE
RED
RED

4-2

LAMP 1

WHITE

LAMP 2

LAMP 4

BALLAST

BLUE
BLUE

LAMP 3

LAMP 3

3-6

4-4

BALLAST

3-5

LAMP 1

BLACK

BALLAST

2-19

YELLOW
YELLOW
/ BLACK
BLACK
WHITE

BLACK
WHITE

2-17

LAMP 2

YELLOW
/ BLACK
YELLOW
BLUE
BLUE
RED
RED

RED

BLUE
BLUE
RED
RED

1-17

BLACK

210

LAMP 2

LAMP

LAMP

BALLAST

LAMP 1
YELLOW
/ BLACK
YELLOW
BLUE
BLUE
BLUE
RED
RED
RED

BLACK
WHITE

6-1

BALLAST

YELLOW
/ BLACK
YELLOW
BLUE
BLUE
BLUE
RED
RED
RED

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Electronic sign Ballasts
Cross Reference Guide and
Lamp Compatibility Specifications
UNIVERSAL/
MAGNETEK

HALCO

ADVANCE

HOWARD

ESB/0216/12

ASB-0412-12-E

ESB216-12

-

ESB/0432/14

ASB-1232-24-E

ESB432-14

-

ESB/0848/46

ASB-2048-46-E

ESB848-46

EBO-6-8-48

ESB/1040/14

-

ESB1040-14

EBO-4-10-40

ESB/0216/12
57114
Lamp Type

# of Lamps

Lamp Footage

Min

Max

Min

Max

T12/HO

1

2

2'

16'

T8/HO

1

2

2'

12'

ESB/0432/14
57116
Lamp Type

# of Lamps

Lamp Footage

Min

Max

Min

Max

T12/HO

1

4

4'

32'

T8/HO

1

4

4'

24'

Min

Max

Min

Max

T12/HO

4

6

8'

48'

T8/HO

4

6

16'

36'

ESB/0848/46
57120
Lamp Type

# of Lamps

Lamp Footage

ESB/1040/14
57118
Lamp Type

# of Lamps

Lamp Footage

Min

Max

Min

Max

T12HO

1

4

10'

40'

T8HO

1

4

8'

32'

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 211

®

COMPACT FLUORESCENT BALLASTS
CONTENTS
214
215
216
218
220
223
223
224

main
TOC

How to Read a Table
PL Single Tube Ballasts
PL Double Tube Ballasts
PL Triple Tube Ballasts
PLL High Lumen Ballasts
Cross Reference Guide
Specifications
Lamp Compatibility Specifications

HOW TO READ A COMPACT FLUORESCENT
BALLAST TABLE
CASE
DIMENSIONS

BALLAST
FACTOR
PRODUCT CODE

Abbreviated product description
can also be used for ordering.

INPUT
VOLTS

Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

WIRING
DIAGRAM

INPUT
POWER

Voltage required
from a power
supply for
proper ballast
operation.

References the wiring
diagram to use.

Total power
input to the
ballast which
includes lamp
watts and
ballast losses.

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Specifies ballast
overall length,
mounting length,
width, and height.

Ratio of the lamp’s lumen
output on the specified
ballast to the lamp’s lumen
output when operated by a
reference ballast.

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case Dimensions
Case

Length Mounting Width Height

PL5S/E/2G7
1
2

5

PS

120

52102

EP2CF13PS/MV/DC/K

0.06

8

0.98

1.10

<10

0°F

1-9

L

5.00”

4.63”

2.40” 1.00”

5

PS

277

52102

EP2CF13PS/MV/DC/K

0.03

9

0.89

1.10

<15

0°F

1-9

L

5.00”

4.63”

2.40” 1.00”

5

PS

120

52102

EP2CF13PS/MV/DC/K

0.11

14

0.99

1.05

<10

0°F

2-6

L

5.00”

4.63”

2.40” 1.00”

5

PS

277

52102

EP2CF13PS/MV/DC/K

0.05

14

0.99

1.05

<10

0°F

2-6

L

5.00”

4.63”

2.40” 1.00”

THD%

LAMP TYPE

LINE
CURRENT

Indicates the type
of lamp that the
ballast will operate.

PRODUCT
NUMBER

Use this number when
placing an order.

The current that
results when the
line voltage is
applied to a load.

POWER
FACTOR

Watts to volt
amps ratio,
which measures
efficiency of a
ballast’s power
usage.

TOC

Indicates
percentage of
Total Harmonic
Distortion.

CASE

References the
ballast’s case shape.

MIN STARTING
TEMP.

References minimum
ambient temperature that
the ballast will reliably
start a lamp.

Compact Fluorescent Ballasts
PL Single Tube
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

PL5S/E/2G7
1
2

5

PS

120

52102

EP2CF13PS/MV/DC/K

0.06

8

0.98

1.10

<10

0°F

1-9

L

5.00”

4.63”

2.40” 1.00”

5

PS

277

52102

EP2CF13PS/MV/DC/K

0.03

9

0.89

1.10

<15

0°F

1-9

L

5.00”

4.63”

2.40” 1.00”

5

PS

120

52102

EP2CF13PS/MV/DC/K

0.11

14

0.99

1.05

<10

0°F

2-6

L

5.00”

4.63”

2.40” 1.00”

5

PS

277

52102

EP2CF13PS/MV/DC/K

0.05

14

0.99

1.05

<10

0°F

2-6

L

5.00”

4.63”

2.40” 1.00”

PL7S/E/2G7
1
2

7

PS

120

52102

EP2CF13PS/MV/DC/K

0.08

11

0.98

1.07

<10

0°F

1-9

L

5.00”

4.63”

2.40” 1.00”

7

PS

277

52102

EP2CF13PS/MV/DC/K

0.04

11

0.91

1.07

<15

0°F

1-9

L

5.00”

4.63”

2.40” 1.00”

7

PS

120

52102

EP2CF13PS/MV/DC/K

0.14

20

0.99

1.03

<10

0°F

2-6

L

5.00”

4.63”

2.40” 1.00”

7

PS

277

52102

EP2CF13PS/MV/DC/K

0.06

16

0.97

1.03

<12

0°F

2-6

L

5.00”

4.63”

2.40” 1.00”

PL9S/E/2G7
1
2

9

PS

120

52102

EP2CF13PS/MV/DC/K

0.10

12

0.99

1.05

<10

0°F

1-9

L

5.00”

4.63”

2.40” 1.00”

9

PS

277

52102

EP2CF13PS/MV/DC/K

0.05

13

0.94

1.05

<15

0°F

1-9

L

5.00”

4.63”

2.40” 1.00”

9

PS

120

52102

EP2CF13PS/MV/DC/K

0.18

22

0.99

1.02

<10

0°F

2-6

L

5.00”

4.63”

2.40” 1.00”

9

PS

277

52102

EP2CF13PS/MV/DC/K

0.08

21

0.97

1.02

<12

0°F

2-6

L

5.00”

4.63”

2.40” 1.00”

Case Diagram

H
M
L

W

L

Wiring Diagrams
RED

BLACK
WHITE

RED

BLACK

YEL.
BALLAST YEL.

WHITE

GREEN

LAMP

GREEN

BLUE

1-9

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

BLUE

RED
RED
BALLAST

YEL.

LAMP 2

YEL.
BLUE
BLUE

LAMP 1

2-6

TOC 215

COMPACT FLUORESCENT BALLASTS
PL Double Tube
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

PL13D/E/G24q
1

2

13

RS

120

50104

E114RS/120

0.22

14

0.53

0.95

<130

0°F

1-5

K

5.90”

5.60”

0.91” 0.76”

13

PS

120

52102

EP2CF13PS/MV/DC/K

0.16

16

0.96

1.00

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

13

PS

277

52102

EP2CF13PS/MV/DC/K

0.07

16

0.96

1.00

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

13

RS

120

52200

E1CF13RS/120/GU24

0.22

14

0.54

1.02

<150

0°F

-

C

2.32”

1.54”

0.90” 1.97”

13

PS

120

52102

EP2CF13PS/MV/DC/K

0.27

29

0.99

1.00

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

13

PS

277

52102

EP2CF13PS/MV/DC/K

0.12

29

0.99

1.00

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

PL18D/E/G24q
1

2

18

PS

120

52102

EP2CF13PS/MV/DC/K

0.17

20

0.99

1.00

<12

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

18

PS

277

52102

EP2CF13PS/MV/DC/K

0.07

20

0.99

1.00

<12

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

18

PS

120

52104

EP2CF18PS/MV/DC/K

0.16

19

0.97

1.00

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

18

PS

277

52104

EP2CF18PS/MV/DC/K

0.07

19

0.97

1.00

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

18

PS

120

52104

EP2CF18PS/MV/DC/K

0.30

35

0.99

0.95

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

18

PS

277

52104

EP2CF18PS/MV/DC/K

0.13

35

0.99

0.95

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

Case Diagrams
M

M

H

L

H

W

K

M

H

L

W

M

L

L

C

D

Wiring Diagrams
BLACK
LINE
WHITE

BALLAST

RED
RED
BLUE
BLUE

BLACK
WHITE

RED
RED

BLACK

YEL.
BALLAST YEL.

WHITE

GREEN

LAMP

1-5

216

TOC

LAMP

GREEN

BLUE

1-9

BLUE

RED
RED
BALLAST

YEL.

LAMP 2

YEL.
BLUE
BLUE

LAMP 1

2-6

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Compact Fluorescent Ballasts
PL Double Tube
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

PL26D/E/G24q

1

2

26

PS

120

52104

EP2CF18PS/MV/DC/K

0.24

28

0.99

1.00

<12

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

26

PS

277

52104

EP2CF18PS/MV/DC/K

0.10

28

0.99

1.00

<12

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

26

PS

120

52106

EP2CF26PS/MV/DC/K

0.24

27

0.98

1.00

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

26

PS

277

52106

EP2CF26PS/MV/DC/K

0.11

27

0.98

1.00

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

26

PS

120

52108

EP2CF42PS/MV/DC/K

0.27

32

0.99

1.00

<10

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

26

PS

277

52108

EP2CF42PS/MV/DC/K

0.13

32

0.95

1.00

<12

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

26

RS

120

52202

E1CF26RS/120/GU24

0.32

22

0.57

0.80

<150

0°F

-

C

2.32”

0.95”

1.54” 1.97”

26

PS

120

52106

EP2CF26PS/MV/DC/K

0.45

51

0.99

1.00

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

26

PS

277

52106

EP2CF26PS/MV/DC/K

0.19

51

0.99

1.00

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

26

PS

120

52108

EP2CF42PS/MV/DC/K

0.45

54

0.99

0.90

<10

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

26

PS

277

52108

EP2CF42PS/MV/DC/K

0.21

54

0.97

0.90

<12

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

Case Diagrams

H
M
L

W

H
M

L

L

C

D

Wiring Diagrams

BLACK
WHITE

RED
RED

BLACK

YEL.
BALLAST YEL.

WHITE

GREEN

LAMP

GREEN

BLUE

1-9

BLUE

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

RED
RED
BALLAST

YEL.

LAMP 2

YEL.
BLUE
BLUE

LAMP 1

2-6

TOC 217

Compact Fluorescent Ballasts
PL Triple Tube
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

PL18T/E/GX24q
1

2

18

PS

120

52102

EP2CF13PS/MV/DC/K

0.17

17

0.99

1.00

<12

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

18

PS

277

52102

EP2CF13PS/MV/DC/K

0.07

17

0.99

1.00

<12

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

18

PS

120

52104

EP2CF18PS/MV/DC/K

0.17

20

0.97

1.05

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

18

PS

277

52104

EP2CF18PS/MV/DC/K

0.08

20

0.97

1.05

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

18

PS

120

52104

EP2CF18PS/MV/DC/K

0.33

39

0.99

1.00

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

18

PS

277

52104

EP2CF18PS/MV/DC/K

0.14

39

0.99

1.00

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

PL26T/E/GX24q

1

2

26

PS

120

52104

EP2CF18PS/MV/DC/K

0.24

28

0.99

1.00

< 12

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

26

PS

277

52104

EP2CF18PS/MV/DC/K

0.10

28

0.99

1.00

<12

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

26

PS

120

52106

EP2CF26PS/MV/DC/K

0.23

29

0.98

1.00

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

26

PS

277

52106

EP2CF26PS/MV/DC/K

0.10

29

0.98

1.00

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

26

PS

120

52108

EP2CF42PS/MV/DC/K

0.27

32

0.99

1.00

<10

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

26

PS

277

52108

EP2CF42PS/MV/DC/K

0.13

32

0.95

1.00

<12

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

26

RS

120

52202

E1CF26RS/120/GU24

0.32

22

0.57

0.80

<150

0°F

-

C

2.32”

0.95”

1.54” 1.97”

26

PS

120

52106

EP2CF26PS/MV/DC/K

0.45

54

0.99

1.00

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

26

PS

277

52106

EP2CF26PS/MV/DC/K

0.19

54

0.99

1.00

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

26

PS

120

52108

EP2CF42PS/MV/DC/K

0.45

54

0.99

0.90

<10

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

26

PS

277

52108

EP2CF42PS/MV/DC/K

0.21

54

0.97

0.90

<12

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

Case Diagrams
H
M

H

L

W

M

L

L

C

D

Wiring Diagrams
BLACK
WHITE

RED
RED

BLACK

YEL.
BALLAST YEL.

WHITE

GREEN

LAMP

GREEN

BLUE

1-9

218

TOC

BLUE

RED
RED
BALLAST

YEL.

LAMP 2

YEL.
BLUE
BLUE

LAMP 1

2-6

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Compact Fluorescent Ballasts
PL Triple Tube
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

PL32T/E/GX24q
1

2

32

PS

120

52106

EP2CF26PS/MV/DC/K

0.26

36

0.98

0.98

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

32

PS

277

52106

EP2CF26PS/MV/DC/K

0.13

36

0.98

0.98

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

32

PS

120

52108

EP2CF42PS/MV/DC/K

0.35

42

0.99

0.96

<10

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

32

PS

277

52108

EP2CF42PS/MV/DC/K

0.13

42

0.96

0.96

<12

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

32

PS

120

52108

EP2CF42PS/MV/DC/K

0.53

63

0.99

0.95

<10

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

32

PS

277

52108

EP2CF42PS/MV/DC/K

0.23

63

0.98

0.95

<12

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

PL42T/E/GX24q
1

2

42

PS

120

52106

EP2CF26PS/MV/DC/K

0.38

46

0.98

0.98

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

42

PS

277

52106

EP2CF26PS/MV/DC/K

0.17

46

0.98

0.98

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

42

PS

120

52108

EP2CF42PS/MV/DC/K

0.40

47

0.99

1.00

<10

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

42

PS

277

52108

EP2CF42PS/MV/DC/K

0.18

47

0.96

1.00

<10

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

42

PS

120

52108

EP2CF42PS/MV/DC/K

0.77

94

0.99

1.00

<10

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

42

PS

277

52108

EP2CF42PS/MV/DC/K

0.38

93

0.98

1.00

<10

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

PL57T/E/GX24q
1

57

PS

120

52106

EP2CF26PS/MV/DC/K

0.43

56

0.99

0.85

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

57

PS

277

52106

EP2CF26PS/MV/DC/K

0.19

56

0.99

0.85

<10

0°F

1-9

L

5.00”

4.63”

2.41” 1.00”

57

PS

120

52108

EP2CF42PS/MV/DC/K

0.49

58

0.99

1.00

<10

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

57

PS

277

52108

EP2CF42PS/MV/DC/K

0.22

58

0.97

1.00

<12

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

Case Diagram
H
M
L

W
L

Wiring Diagrams
RED

BLACK
WHITE

RED

BLACK

YEL.
BALLAST YEL.

WHITE

GREEN

LAMP

GREEN

BLUE

1-9

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

BLUE

RED
RED
BALLAST

YEL.

LAMP 2

YEL.
BLUE
BLUE

LAMP 1

2-6

TOC 219

Compact Fluorescent Ballasts
PLL High Lumen
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

PLL18/2G11
2

18

PS

120

52106

EP2CF26PS/MV/DC/K

0.31

35

0.99

0.92

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

18

PS

277

52106

EP2CF26PS/MV/DC/K

0.14

35

0.99

0.92

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

PLL24/2G11
1

2

24

PS

120

50142

EP239HO/PS/MV

0.24

29

0.98

1.12

<20

0°F

1-9

J

16.90” 16.00”

1.20” 1.00”

24

PS

277

50142

EP239HO/PS/MV

0.12

29

0.98

1.12

<20

0°F

1-9

J

16.90” 16.00”

1.20” 1.00”

24

PS

120

52108

EP2CF42PS/MV/DC/K

0.22

27

0.99

1.00

<10

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

24

PS

277

52108

EP2CF42PS/MV/DC/K

0.11

28

0.92

1.00

<15

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

24

PS

120

50142

EP239HO/PS/MV

0.46

54

0.98

1.10

<10

0°F

2-6

J

16.90” 16.00”

1.20” 1.00”

24

PS

277

50142

EP239HO/PS/MV

0.20

54

0.98

1.10

<10

0°F

2-6

J

16.90” 16.00”

1.20” 1.00”

24

PS

120

52106

EP2CF26PS/MV/DC/K

0.43

48

0.99

0.93

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

24

PS

277

52106

EP2CF26PS/MV/DC/K

0.18

48

0.99

0.93

<10

0°F

2-6

L

5.00”

4.63”

2.41” 1.00”

24

PS

120

52108

EP2CF42PS/MV/DC/K

0.45

54

0.99

1.00

<10

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

24

PS

277

52108

EP2CF42PS/MV/DC/K

0.20

54

0.97

1.00

<10

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

Case Diagrams

M
H

L

W

H

J

M
L

W
L

Wiring Diagrams
BLACK
WHITE

RED
RED

BLACK

YEL.
BALLAST YEL.

WHITE

GREEN

LAMP

GREEN

BLUE

1-9

220

TOC

BLUE

RED
RED
BALLAST

YEL.

LAMP 2

YEL.
BLUE
BLUE

LAMP 1

2-6

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Compact Fluorescent Ballasts
PLL High Lumen
Lamp Type
Qty. Watts

Start
Type

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

PLL36/2G11
1

2

36

PS

120

50142

EP239HO/PS/MV

0.30

36

0.98

0.96

<15

0°F

1-9

J

16.90” 16.00”

1.20” 1.00”

36

PS

277

50142

EP239HO/PS/MV

0.20

36

0.98

0.96

<15

0°F

1-9

J

16.90” 16.00”

1.20” 1.00”

36

PS

120

52108

EP2CF42PS/MV/DC/K

0.31

37

0.99

0.88

<10

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

36

PS

277

52108

EP2CF42PS/MV/DC/K

0.14

37

0.95

0.88

<12

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

36

PS

120

50142

EP239HO/PS/MV

0.59

69

0.94

0.94

<10

0°F

2-6

J

16.90” 16.00”

1.20” 1.00”

36

PS

277

50142

EP239HO/PS/MV

0.25

69

0.98

0.94

<10

0°F

2-6

J

16.90” 16.00”

1.20” 1.00”

36

PS

120

52108

EP2CF42PS/MV/DC/K

0.55

66

0.99

0.80

<10

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

36

PS

277

52108

EP2CF42PS/MV/DC/K

0.24

65

0.98

0.80

<10

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

Case Diagrams

M
H

L

H
W

J

M
L

W
L

Wiring Diagrams
BLACK
WHITE

RED
RED

BLACK

YEL.
BALLAST YEL.

WHITE

GREEN

LAMP

GREEN

BLUE

1-9

BLUE

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

RED
RED
BALLAST

YEL.

LAMP 2

YEL.
BLUE
BLUE

LAMP 1

2-6

TOC 221

COMPACT FLUORESCENT BALLASTS
PLL High Lumen
Lamp Type
Start
Type

Qty. Watts

Input
Volts

Product
Number

Product Code

Case Dimensions

Line
Current
(Amps)

Input
Power
(Watts)

Power
Factor

Ballast
Factor

THD %

Min.
Start
Temp

Wire
Diag.

Case

Length Mounting Width Height

PLL40/2G11
1

2
3

40

PS

120

50142

EP239HO/PS/MV

0.42

50

0.98

1.10

<10

0°F

1-9

J

16.90” 16.00”

1.20” 1.00”

40

PS

277

50142

EP239HO/PS/MV

0.19

50

0.98

1.10

<10

0°F

1-9

J

16.90” 16.00”

1.20” 1.00”

40

PS

120

52108

EP2CF42PS/MV/DC/K

0.37

45

0.99

1.00

<10

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

40

PS

277

52108

EP2CF42PS/MV/DC/K

0.17

45

0.96

1.00

<12

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

40

PS

120

52108

EP2CF42PS/MV/DC/K

0.69

82

0.99

0.95

<10

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

40

PS

277

52108

EP2CF42PS/MV/DC/K

0.30

82

0.98

0.95

<10

0°F

2-6

L

5.00”

4.63”

3.00” 1.38”

40

IS

120

50124

EP432IS/120/SL

0.82

107

0.99

0.88

<10

0°F

3-4

F

9.50”

8.82”

1.70”

1.15”

PLL55/2G11
1

2

55

PS

120

50144

EP254HO/PS/MV

0.49

58

0.96

0.92

<15

0°F

1-9

J

16.90” 16.00”

1.20” 1.00”

55

PS

277

50144

EP254HO/PS/MV

0.22

58

0.96

0.92

<15

0°F

1-9

J

16.90” 16.00”

1.20” 1.00”

55

PS

120

52108

EP2CF42PS/MV/DC/K

0.37

44

0.99

0.70

<10

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

55

PS

277

52108

EP2CF42PS/MV/DC/K

0.17

44

0.96

0.70

<12

0°F

1-9

L

5.00”

4.63”

3.00” 1.38”

55

PS

120

50144

EP254HO/PS/MV

0.94

112

0.98

0.90

<10

0°F

2-6

J

16.90” 16.00”

1.20” 1.00”

55

PS

277

50144

EP254HO/PS/MV

0.41

112

0.98

0.90

<10

0°F

2-6

J

16.90” 16.00”

1.20” 1.00”

Case Diagrams

M

H

M

L

H

L

W

H

W

F

J

M
L

W
L

Wiring Diagrams
LAMP 3

BLACK
WHITE

RED
RED

BLACK

YEL.
BALLAST YEL.

WHITE

GREEN

LAMP

GREEN

BLUE

1-9

222

TOC

BLUE

RED

BALLAST

YEL.

LAMP 2

LAMP 1

YEL.
BLUE
BLUE

2-6

LAMP 2

RED

YEL

LAMP 1
LINE

3-4

YEL
BLACK

BALLAST

BLUE
BLUE
RED
RED

WHITE

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Compact Fluorescent Ballasts
Cross Reference Guide and Specifications
HALCO

ADVANCE

UNIVERSAL/
MAGNETEK

HOWARD

EP2CF13PS/MV/DC/K

ICF-2S13-H1-LD

C213UNV

EP2/13CF/MV/K

EP2CF18PS/MV/DC/K

ICF-2S18-H1-LD

C218UNV

EP2/18CF/MV/K

EP2CF26PS/MV/DC/K

ICF-2S26-H1-LD

C2642UNV

EP2/26CF/MV/K2

EP2CF42PS/MV/DC/K

ICF-2S42-M2-LD

C242UNV

EP2/42CF/MV/K2

SPECIFICATIONS
Ballast shall have a Lamp Current Crest Factor of <1.7 in accordance with ANSI C82.1.
Ballast shall withstand line voltage transients and surges as specified in ANSI standard
C62.41-1991.
Ballast shall have an Underwriters Laboratories certification for operation in the US and
either an Underwriters Laboratories or Canadian Standards Association certification for
operation in Canada.
Ballast shall comply with the EMI and RFI limits of the code of Federal Regulations, Title 47,
Part 18C for Non-Consumer equipment.
Ballast shall operate in the range of 50-60Hz input frequency.
Ballast shall operate at a maximum of 18 feet remote mounting distance for primary lamp.
For energy saving reduced wattages lamps, remote mounting distances will be shorter.
Ballast shall operate at a frequency of 20-40 kHz.
Ballast shall contain potting compound in order to protect from moisture, dissipate heat and
provide stability.
All ProFormance ballasts shall have a power factor of 0.98 or better on the primary lamp
configuration.
Ballast shall be sound rated Class A.
Ballast shall have a minimum starting temperature of 0˚F standard lamps and 60°F on
Energy Saving lamps.
Ballast shall tolerate sustained variations of +/-10% of supply voltage with
no damage to the ballast.
Ballast shall not contain PCBs.
Manufacturer shall provide written warranty against defects in material or workmanship
for 5 years from date of manufacture.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC

223

Compact Fluorescent Ballasts
Lamp Compatibility Specifications
EP2CF13PS/MV/DC/K
52102
Lamp Type

EP2CF18PS/MV/DC/K
52104

# of
Lamps

Lamp Type

EP2CF26PS/MV/DC/K
52106

# of
Lamps

Lamp Type

EP2CF42PS/MV/DC/K
52108

# of
Lamps

Lamp Type

# of
Lamps

PL13D/E/G24q

1, 2

PL18D/E/G24q

1, 2

PL26D/E/G24q

1, 2

PL42T/E/GX24q

1, 2

PL13T/E/GX24q

1, 2

PL18T/E/GX24q

1, 2

PL57D/E/G24q

1

PL32T/E/GX24q

1, 2

PL18T/E/GX24q

1, 2

PL26D/E/G24q

1, 2

PL26T/E/GX24q

1, 2

PL26D/E/G24q

1, 2

PL10/2D/GR10q

1, 2

PL16/2D/GR10q

1, 2

PL32T/E/GX24q

1

PL26T/E/GX24q

1, 2

PL16/2D/GR10q

1, 2

PL21/2D/GR10q

1, 2

PL42T/E/GX24q

1

PLL39/2G11

1, 2

F14T5

1, 2

PL28/2D/GR10q

1

PL57T/E/GX24q

1

PLL40/2G11

1, 2

F13T5

1, 2

PLL18/2G11

2

PLL36/2G11

1, 2

PL5/S/E/2G7

1, 2

PLL24/2G11

1, 2

PLL24/2G11

1, 2

PL7/S/E/2G7

1, 2

PLL36/2G11

1

PL57T/E/GX24q

1

PL9/S/E/2G7

1, 2

PLL40/2G11

1

PL28/2D/GR10q

2

PL21/2D/GR10q

2

PL28/2D/GR10q

1

PL28/2D/GR10q

1

FC22T5 + FC40T5

2

FC40T5

1

FC22T5

2

FC22T5

1

FC22T5

1

FC16T9

1

FC40T5

2

FC40T5

1

E1CF13RS/120/GU24
52200
Lamp Type

E1CF26RS/120/GU24
52202
# of
Lamps

Lamp Type

# of
Lamps

PL13D/E/G24q

1

PL26D/E/G24q

1

PL13T/E/GX24q

1

PL26T/E/GX24q

1

224

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

®

ELECTRONIC HID BALLASTS
CONTENTS
228
229
229
230
231

main
TOC

How to Read a Table
Ceramic Discharge Metal Halide Ballasts
Case Dimensions and Wiring Diagrams
Cross Reference Guide
Specifications

HOW TO READ AN ELECTRONIC HID
BALLAST TABLE

PRODUCT
CODE

NUMBER
OF LAMPS

Abbreviated product
description can also be
used for ordering.

Indicates the number
of lamps the ballast
will operate.

INPUT
VOLTS

Input
Volts

Product
Number

Maximum voltage
pulse provided
by the ignitor to
initiate an electrical
discharge in a gas
filled tube.

INPUT
POWER

Voltage required
from a power
supply for
proper ballast
operation.

No. of
Lamps

MAX
IGNITION
PULSE

BALLAST
FACTOR

Ratio of the lamp’s
lumen output
on the specified
ballast to the lamp’s
lumen output when
operated by a
reference ballast.

Total power
input to the
ballast which
includes lamp
watts and
ballast losses.

Product Code

Input
Power
(Watts)

Nominal
Line
Amps

WIRING
DIAGRAM

References the
wiring diagram
to use.

BALLAST
DIMENSIONS
Specifies ballast
overall length,
width, and height.

Ballast Dimensions

Max
Ignition
Pulse

Power
Factor

Ballast
Factor

Fig

Overall
Length

Width

Height

Total Ballast
Case Weight
(lbs)

Wiring
Diagram

3.5 kV

0.96

1.00

N1

3.69”

2.59”

1.18”

0.57

1-22

3.5 kV

0.96

1.00

E1

4.43”

2.59”

1.18”

0.57

1-22

20 Watt CDM Lamp, ANSI Code C156 or M156
1
1

120
277
120
277

55504

C156/20E/MV/BE

23

55502

C156/20E/MV/SE

23

0.19
0.09
0.19
0.09

PRODUCT
NUMBER
LAMP TYPE

Indicates the type
of lamp that the
ballast will operate.

Use this number when
placing an order.

FIGURE

Representation
of the ballast.

NOMINAL
LINE AMPS

Ballast’s rated line
current. Typically
the middle of an
acceptable range.

POWER
FACTOR

Watts to volt amps
ratio, which measures
efficiency of a ballast’s
power usage.

TOC

TOTAL BALLAST
CASE WEIGHT
Total weight of ballast
to include case.

Electronic HID Ballasts
Ceramic Discharge Metal Halide

No. of
Lamps

Input
Volts

Product
Number

Product Code

Input
Power
(Watts)

Nominal
Line
Amps

Ballast Dimensions

Max
Ignition
Pulse

Power
Factor

Ballast
Factor

Fig

Overall
Length

Height

Total Ballast
Case Weight
(lbs)

Width

Wiring
Diagram

3.5 kV

0.96

1.00

N1

3.69”

2.59”

1.18”

0.57

1-22

3.5 kV

0.96

1.00

E1

4.43”

2.59”

1.18”

0.57

1-22

3.8 kV

0.96

1.00

N1

3.69”

2.59”

1.18”

0.57

1-22

3.8 kV

0.96

1.00

E1

4.43”

2.59”

1.18”

0.57

1-22

20 Watt CDM Lamp, ANSI Code C156 or M156
120

1

277
120

1

277

55504

C156/20E/MV/BE

23

55502

C156/20E/MV/SE

23

0.19
0.09
0.19
0.09

39 Watt CDM Lamp, ANSI Code C130 or M130
120

1

277
120

1

277

55508

C130/35E/MV/BE

43

55506

C130/35E/MV/SE

43

0.32
0.14
0.32
0.14

70 Watt CDM Lamp, ANSI Code C143 or M143; C139 or M139; C98 or M98
120

1

277
120

1

277

55512

C139/70E/MV/BE

77

55510

C139/70E/MV/SE

77

0.65
0.29
0.65
0.29

Ballast Dimensions

0.98

1.00

N2

4.15”

3.10”

1.16”

1.06

1-22

4.0 kV

0.98

1.00

E2

4.83”

3.10”

1.15”

1.06

1-22

Drawing #

Overall
Length

Case
Length (L)

Case
Width (W)

Case
Height(H)

Mounting
Length (M1)

Mounting
Length (M2)

E1

4.43”

3.69”

2.59”

1.18”

4.13”

1.89"

E2

4.83”

4.15”

3.10”

1.15”

4.52”

2.45”

N1

3.69”

3.69”

2.59”

1.18”

2.00”

0.26"

N2

4.15"

4.15"

3.10"

1.16"

2.00"

0.26"

M1

H

W

4.0 kV

L

E

M1

H

L

W

N

Wiring Diagram
BLACK
WHITE
GREEN

ORANGE

BALLAST

LAMP

BROWN

1-22

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 229

Electronic HID Ballasts
Cross Reference Guide
HALCO

ADVANCE

UNIVERSAL/
MAGNETEK

HOWARD

M102/150HX/4T/K

71A5492-001D

M150MLTLC3M500K

M0150-71C-512-K

M110/50HX/4T/K

71A5191-001D

M50MLTLC3M500K

M0050-23C-511-K

M141/1000CWA/4T/K

71A6593-001

P1000MLTAC5M500K

M1000-71C-612-K

M141/1000CWA/5T/K

71A6552-001D

P1000ML5AC5M500K

M1000-81C-611-K

M149/750CWA/4T/K

71A64F2-001D

P750MLTAC5M500K

M0750-71C-612-K

M149/750CWA/5T/K

71A6452-001D

P750ML5AC5M500K

M0750-81C-612-K

M131/350CWA/4T/K

71A5993-001D

P350MLTAC4M500K

M0350-71C-6E4-K

M131/350CWA/5T/K

71A5953-001D

P350ML5AC4M500K

-

M132/320CWA/4T/K

71A5892-001D

P320MLTAC4O500K

M0320-71C-6E4-K

M132/320CWA/5T/K

71A5852-001D

P320ML5AC4L500K

-

M135/400CWA/4T/K

71A6092-001D

P400MLTAC4L500K

M0400-71C-6E3-K

M135/400CWA/5T/K

-

P400ML5AC4M500K

-

M138/250CWA/4T/K

71A5792-001D

P250MLTAC4L500K

M0250-71C-611-K

M138/250CWA/5T/K

-

P250ML5AC4M500K

-

M150/125CWA/4T/K

-

-

-

M90/100HX/4T/K

71A5390-001D

M100MLTLC3M500K

M0100-71C-512-K

M98/70HX/4T/K

71A5292-001D

M70MLTLC3M500K

M0070-71C-511-K

230

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Electronic HID Ballasts
Specifications
SPECIFICATIONS
Ballast shall be furnished with integral, color-coded leads.
Ballast shall tolerate sustained variations of +/- 10% of supply voltage with no
damage to the ballast.
Ballast shall operate in the range of 50-60Hz input frequency.
Ballast shall operate at a maximum of 6 feet remote mounting distance.
Ballast shall be microprocessor controlled.
Ballast shall have integrated thermal, transient and end-of-life protection.
Ballast shall be thermally protected to shut off when operating temperatures
reach unacceptable levels.
Ballast shall have an Underwriters Laboratories certification for operation in the US and
either an Underwriters Laboratories or Canadian Standards Association certification for
operation in Canada.
Ballast shall comply with EMI and RFI limits of the code of Federal Regulations, Title 47,
Part 18C for Non-Consumer equipment.
Ballast shall have a Lamp Current Crest Factor of <1.7.
Ballast shall provide the lamp with a low frequency square wave form to minimize visible
flicker and increase lamp life.
Ballast shall be Sound Rated Class A.
Ballast input current shall have a Total Harmonic Distortion of <15%.
Ballast shall have a Power Factor greater than 90%.
Ballast shall have a lamp end-of-life detection and shut down circuit.
Ballast shall not contain PCBs.
Manufacturer shall provide written warranty against defects in material or workmanship
for 3 years from date of manufacture.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 231

®

ELECTROMAGNETIC HID BALLASTS
CONTENTS
234 How to Read a Table
235 Pulse Start Metal Halide Ballasts
239 Standard Metal Halide Ballasts
242 High Pressure Sodium Ballasts
245 Capacitor Guide
246 Ignitor Guide
247 Cross Reference Guide
249 Specifications

main
TOC

HOW TO READ AN ELECTROMAGNETIC HID
BALLAST TABLE

FUSE RATING

PRODUCT
CODE

INPUT
VOLTS

Product
Number

CAPACITOR (Mfd, volts)

Specifies the electrical characteristics
of the capacitor.

INPUT
POWER

Voltage required
from a power
supply for
proper ballast
operation.

To facilitate UL
inspection, the
UL Bench Top
Rise Temperature
Code is shown
on the Halco Core
& Coil Ballast
label as 1029X.

Ballast’s maximum
fuse rating.

Abbreviated product
description can also be
used for ordering.

Input
Volts

UL BENCH
TOP RISE

Total power
input to the
ballast which
includes lamp
watts and
ballast losses.

Product Code

Circuit
Type

Nom.
Input Max Input
Open
Power
Current
Circuit
(Watts)
(Amps)
Volts

Fuse
Rating
(Amps)

Dimensions
Fig

A Max

Capacitor

B Max

Mfd Volts

Ignitor
(IGN/)

Kit Weight (lbs)
Total Ballast
Weight Weight

UL Bench
Top Rise

50 Watt Pulse Start MH Lamp, ANSI Code M110
120

0.60

5

A

208

0.40

3

A

240

55192

M110/50HX/4T/K

HX-HPF

65

277

Use this number when
placing an order.

Indicates the type
of lamp that the
ballast will operate.

258

0.30

3

CIRCUIT
TYPE

Indicates the ballast
circuit type.

1.05

2.48

6

280

MH1

4.92

3.10

2

Typically the
middle of a ballast’s
acceptable Open
Circuit Voltage range.

MAX INPUT
CURRENT (Amps)

For HX and R circuits, value is
the highest of starting operating
or open circuit current. For CWA
or Super CWA circuits, value is
the operating current.

TOC

E

Nominal
Open
Circuit
Volts

PRODUCT
NUMBER

LAMP TYPE

0.30

A
A

IGNITOR

Identifies the
Halco ignitor
product code
to be used with
the ballast.

BALLAST
DIMENSIONS
Indicates
ballast’s size.

KIT
WEIGHT

Total weight
of ballast to
include case.

ELECTROMAGNETIC HID BALLASTS
Pulse Start Metal Halide
Input
Volts

Product
Number

Product Code

Circuit
Type

Nom.
Input Max Input
Open
Power
Current
Circuit
(Watts)
(Amps)
Volts

Fuse
Rating
(Amps)

Dimensions
Fig

A Max

B Max

Capacitor
Mfd Volts

Ignitor
(IGN/)

Kit Weight (lbs)
Total Ballast
Weight Weight

UL Bench
Top Rise

50 Watt Pulse Start MH Lamp, ANSI Code M110
120
208
240

0.60
55192

M110/50HX/4T/K

HX-HPF

65

277

0.40
0.30

5
258

3
3

A
E

1.05

2.48

6

280

MH1

4.92

3.10

A
A

0.30

2

A

1.60

4

A

70 Watt Pulse Start MH Lamp, ANSI Code M98
120
208
240

55134

M98/70HX/4T/K

HX-HPF

85

277

0.90
0.80

252

0.70

3
3

E

1.47

2.90

8

280

MH1

6.75

4.50

A
A

2

A

8

A

100 Watt Pulse Start MH Lamp, ANSI Code M90
120
208
240

2.40
55136

M90/100HX/4T/K

HX-HPF

120

277

1.40
1.20

276

1.10

6
4

E

1.58

2.96

12

280

MH1

6.28

4.80

A
A

4

A

4

A

125 Watt Pulse Start MH Lamp, ANSI Code M150
120
208
240

1.25
55170

M150/125CWA/4T/K

Super
CWA

150

277

0.75
0.65

228

0.55

3
2

E

1.70

3.10

12

280

MH1

6.00

5.80

A
A

2

A

10

A

150 Watt Pulse Start MH Lamp, ANSI Code M102
120
208
240

1.60
55138

M102/150HX/4T/K

HX-HPF

182

277

1.00
0.90
0.80

255

5
5

E

2.28

3.80

16

280

4

MH1

9.06

6.80

A
A
A

Ballast Dimensions
B max

A max

2 13/16"
2 7/16"

3 1/2"
3 15/16"

4 Holes >= 0.25"
Cleared for #10 bolts

Figure E

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 235

ELECTROMAGNETIC HID BALLASTS
Pulse Start Metal Halide
Input
Volts

Product
Number

Product Code

Circuit
Type

Nom.
Input Max Input
Open
Power
Current
Circuit
(Watts)
(Amps)
Volts

Fuse
Rating
(Amps)

Capacitor

Dimensions
Fig

A Max

B Max

Mfd Volts

Ignitor
(IGN/)

Kit Weight (lbs)
Total Ballast
Weight Weight

UL Bench
Top Rise

250 Watt Pulse Start MH Lamp, ANSI Code M138 or M153
120
208
240

2.45
55160

M138/250CWA/4T/K

Super
CWA

278

1.40
1.25

10
6

274

A
I

6

1.85

3.78

15

400

MH2

11.79

9.80

A
A

277

1.10

5

A

120

2.45

12

A

1.40

6

A

208
240

55174

M138/250CWA/5T/K

277

Super
CWA

282

480

1.25

286

6

I

1.99

3.90

15

400

MH2

10.30 11.50

A

1.10

5

A

0.65

3

A

10

B

320 Watt Pulse Start MH Lamp, ANSI Code M132 or M154
120
208
240

3.10
55148

M132/320CWA/4T/K

Super
CWA

361

1.80
1.55

6

279

I

6

2.18

4.40

21

360

MH2

12.20 11.00

B
B

277

1.35

5

B

120

3.10

12

C

208

1.80

8

C

240

55176

M132/320CWA/5T/K

277

Super
CWA

355

480

1.55

276

6

I

2.18

4.40

21

345

MH2

11.88 11.50

C

1.35

5

C

0.78

3

C

12

A

350 Watt Pulse Start MH Lamp, ANSI Code M131
120
208
240

3.30
55150

M131/350CWA/4T/K

Super
CWA

400

1.90
1.60

6

257

I

6

2.32

4.40

24

400

MH2

12.50 11.80

A
A

277

1.40

5

A

120

3.40

10

A

2.00

7

A

208
240

55172

M131/350CWA/5T/K

277

Super
CWA

410

480

1.70

265

5

I

2.32

4.40

24

330

MH2

12.80 12.20

A

1.50

5

A

0.90

3

A

Ballast Dimensions
B max

A max

4 1/4"
3 7/8"

4 3/8"
Figure I
236

TOC

4 3/4"

4 Holes >= 0.25"
Cleared for #10 bolts
Halco Lighting Technologies | 800.677.3334 | halcolighting.com

ELECTROMAGNETIC HID BALLASTS
Pulse Start Metal Halide
Input
Volts

Product
Number

Circuit
Type

Product Code

Nom.
Input Max Input
Open
Power
Current
Circuit
(Watts)
(Amps)
Volts

Fuse
Rating
(Amps)

Dimensions
Fig

A Max

B Max

Capacitor
Mfd Volts

Ignitor
(IGN/)

Kit Weight (lbs)
Total Ballast
Weight Weight

UL Bench
Top Rise

400 Watt Pulse Start MH Lamp, ANSI Code M135 or M155
120
208
240

4.00
55162

M135/400CWA/4T/K

Super
CWA

460

2.30
2.00

12
282

6
6

B
I

2.32

4.30

26

400

MH2

11.50 11.20

C
D

277

1.75

5

D

120

3.81

12

A

2.15

6

A

208
240

55178

M135/400CWA/5T/K

277

Super
CWA

458

480

1.92

268

6

I

2.32

4.25

26

400

MH2

16.98 12.20

A

1.67

5

A

0.93

3

A

A

750 Watt Pulse Start MH Lamp, ANSI Code M149 or M181
120

7.23

20

208

4.05

10

240

55188

M149/750CWA/4T/K

Super
CWA

842

3.64

370

10

O

2.62

4.80

24

480

-

20.28 17.00

A
A

277

3.13

8

A

120

7.20

20

A

4.10

10

A

208
240

55190

M149/750CWA/5T/K

277

Super
CWA

810

480

3.60

371

10

O

2.84

4.80

24

480

-

20.28 18.80

A

3.13

8

A

1.80

6

A

Ballast Dimensions

B max

B max

A max

A max

4 1/4"

4 1/4"
3 7/8"

3 7/8"

4 3/8"
Figure I

4 3/4"

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

4 3/8"

4 Holes >= 0.25"
Cleared for #10 bolts

5 3/8"
Figure O

6"

8 Holes >= 0.25"
Cleared for #10 bolts

TOC 237

Electromagnetic hid ballastS
Pulse Start Metal Halide
Input
Volts

Product
Number

Product Code

Circuit
Type

Nom.
Input Max Input
Open
Power
Current
Circuit
(Watts)
(Amps)
Volts

Fuse
Rating
(Amps)

Capacitor

Dimensions
Fig

A Max

B Max

Mfd Volts

Ignitor
(IGN/)

Kit Weight (lbs)
Total Ballast
Weight Weight

UL Bench
Top Rise

875 Watt Pulse Start MH Lamp, ANSI Code M166
120
208
240

8.10
55194

M166/875CWA/4T/K

Super
CWA

930

4.70
4.10

20
400

15
10

A
O

3.01

4.92

22

480

-

23.39 19.40

A
A

277

3.60

10

A

120

8.20

20

A

208
240

55196

M166/875CWA/5T/K

277

Super
CWA

4.80
930

480

4.30

12
400

10

A
O

3.01

4.92

22

480

-

22.68 19.40

A

3.60

10

A

2.10

8

A

A

1000 Watt Pulse Start MH Lamp, ANSI Code M141
120

9.20

20

208

5.30

15

240

55184

M141/1000CWA/4T/K

Super
CWA

1090

4.60

404

10

O

3.01

5.05

24

480

-

20.24 20.10

A
A

277

4.00

10

A

120

8.80

20

A

5.10

15

A

208
240

55186

M141/100CWA/5T/K

277

Super
CWA

1070

480

4.50

413

10

O

3.25

5.22

21.4 480

-

21.40 21.40

A

3.90

10

A

2.30

8

A

Ballast Dimensions
B max

A max

4 1/4"
3 7/8"

4 3/8"
5 3/8"
6"

8 Holes >= 0.25"
Cleared for #10 bolts

Figure O

238

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

ELECTROMAGNETIC HID BALLASTS
Standard Metal Halide
Input
Volts

Product
Number

Circuit
Type

Product Code

Nom.
Input Max Input
Open
Power
Current
Circuit
(Watts)
(Amps)
Volts

Fuse
Rating
(Amps)

1.80

10

Dimensions
Fig

A Max

B Max

Capacitor
Mfd Volts

Ignitor
(IGN/)

Kit Weight (lbs)
Total Ballast
Weight Weight

UL Bench
Top Rise

175 Watt MH Lamp, ANSI Code M57
120
208
240

55140

M57/175CWA/4T/K

CWA

202

1.00
0.90

282

5
4

A
E

2.60

4.02

10

400

-

8.90

A

6.90

A

277

0.80

3

A

120

1.90

10

A

208

1.10

5

A

240

55142

M57/175CWA/5T/K

CWA

210

0.90

302

5

E

2.44

4.10

10

400

-

8.90

6.90

A

277

0.80

3

A

480

0.50

2

A

2.60

10

A

250 Watt MH Lamp, ANSI Code M58
120
208
240

55144

M58/250CWA/4T/K

CWA

295

1.50
1.30

304

6
5

I

1.61

3.54

15

400

-

10.20

A

8.00

A

277

1.15

5

A

120

2.50

10

A

208

1.45

6

A

240

55146

M58/250CWA/5T/K

CWA

289

1.25

307

5

I

1.85

3.70

15

400

-

12.60 10.40

A

277

1.50

5

A

480

0.65

3

A

Ballast Dimensions
B max

B max

A max

A max

4 1/4"

2 13/16"
2 7/16"

3 1/2"
Figure E

3 15/16"

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

3 7/8"

4 3/8"

4 Holes >= 0.25"

Cleared for #10 bolts
Figure I

4 3/4"

4 Holes >= 0.25"

Cleared for #10 bolts

TOC 239

ELECTROMAGNETIC HID BALLASTS
Standard Metal Halide
Input
Volts

Product
Number

Circuit
Type

Product Code

Nom.
Input Max Input
Open
Power
Current
Circuit
(Watts)
(Amps)
Volts

Fuse
Rating
(Amps)

4.00

12

Capacitor

Dimensions
Fig

A Max

B Max

Mfd Volts

Ignitor
(IGN/)

Kit Weight (lbs)
Total Ballast
Weight Weight

UL Bench
Top Rise

400 Watt MH Lamp, ANSI Code M59
120
208
240

55152

M59/400CWA/4T/K

CWA

458

2.30
2.00

300

8
6

B
I

2.16

4.30

24

360

-

13.32 11.04

C
C

277

1.80

6

D

120

4.00

12

B

208

2.30

8

B

240

55154

M59/400CWA/5T/K

CWA

452

2.00

300

6

I

2.32

4.34

24

400

-

14.64 11.40

C

277

1.80

6

C

480

1.00

4

C

9.20

20

A

1000 Watt MH Lamp, ANSI Code M47
120
208
240

55156

M47/1000CWA/4T/K

CWA

1076

5.30
4.60

411

15
10

O

3.01

4.92

24

480

-

22.52 18.90

A
A

277

4.00

10

A

120

9.20

20

A

208

5.30

15

A

240

55158

M47/1000CWA/5T/K

CWA

1087

4.60

420

10

O

3.25

5.20

24

480

-

24.06 19.90

A

277

4.00

10

A

480

2.30

6

A

Ballast Dimensions

B max

B max

A max

A max

4 1/4"

4 1/4"
3 7/8"

3 7/8"

4 3/8"
4 3/4"
Figure I

240

TOC

4 3/8"

4 Holes >= 0.25"

5 3/8"

Cleared for #10 bolts

6"

8 Holes >= 0.25"
Cleared for #10 bolts

Figure O

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

electromagnetic hid Ballasts
Standard Metal Halide
Input
Volts

Product
Number

Product Code

Circuit
Type

Nom.
Input Max Input
Open
Power
Current
Circuit
(Watts)
(Amps)
Volts

Fuse
Rating
(Amps)

13.20

30

Dimensions
Fig

A Max

B Max

Capacitor
Mfd Volts

Ignitor
(IGN/)

Kit Weight (lbs)
Total Ballast
Weight Weight

UL Bench
Top Rise

1500 Watt MH Lamp, ANSI Code M48
120
208
240

55180

M48/1500CWA/4T/K

CWA

1542

7.60

430

6.70

25
20

B
O

4.49

6.85

32

525

-

32.34 28.00

A
A

277

5.80

15

A

120

13.00

44

C

208

7.50

22

C

240

55182

M48/1500CWA/5T/K

CWA

1550

6.50

430

20

O

4.49

6.90

32

525

-

32.34 29.00

B

277

5.70

17

B

480

3.30

10

A

Ballast Dimensions
B max

A max

4 1/4"
3 7/8"

4 3/8"
5 3/8"
6"

8 Holes >= 0.25"
Cleared for #10 bolts

Figure O

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 241

ELECTROMAGNETIC HID BALLASTS
High Pressure Sodium
Input
Volts

Product
Number

Product Code

Circuit
Type

Nom.
Input Max Input
Open
Power
Current
Circuit
(Watts)
(Amps)
Volts

Capacitor

Dimensions

Fuse
Rating
(Amps)

Fig

A Max

B Max

Mfd Volts

Ignitor
(IGN/)

Kit Weight (lbs)
Total Ballast
Weight Weight

UL Bench
Top Rise

35 Watt HPS Lamp, ANSI Code S76
120

55102

S76/35R/120/K

*R-HPF

54

0.80

120

3

A

0.61

1.80

14

120

HPS1

1.97

1.10

A

61

1.20

120

4

A

0.83

2.00

20

120

HPS1

2.40

1.70

A

83

1.65

120

4

A

1.30

2.50

28

120

HPS1

3.22

2.00

A

50 Watt HPS Lamp, ANSI Code S68
120

55104

S68/50R/120/K

*R-HPF

70 Watt HPS Lamp, ANSI Code S62
120

55106

S62/70R/120/K

*R-HPF

120
208
240

1.40
55108

S62/70HX/4T/K

HX-HPF

95

277

0.80
0.70

3
125

0.60

2
2

A
E

1.54

2.95

7

280

HPS1

6.79

4.60

2

A
A
A

100 Watt HPS Lamp, ANSI Code S54
120

55110

S54/100R/120/K

*R-HPF

116

2.10

120

5

120

2.20

4

208

1.30

3

240

55112

S54/100HX/4T/K

HX-HPF

130

277

1.10

118

1.00

2

A

1.77

2.95

36

120

HPS1

3.63

2.50

A
A

E

1.97

3.35

10

280

HPS1

8.26

6.00

2

A
A
A

150 Watt HPS Lamp, ANSI Code S55
120

55114

S55/150R/120/K

*R-HPF

168

120
208
240

3.10

120

3.00
55116

S55/150HX/4T/K

HX-HPF

182

277

1.70
1.50
1.30

6

A

2.36

3.54

55

120

HPS1

5.46

3.25

5
121

3
3

A
A

E

2.56

4.05

14

280

HPS1

8.73

7.40

3

A
A
A

*Ballast operates at High Power Factor when capacitor (not included with kit) is installed. If the capacitor is omitted, ballast will operate at Normal Power Factor.

Ballast Dimensions
B max

B max

A max

2 7/32"

2 13/16"

1 25/32"

2 7/16"

A max
2 3/16"

Figure A

242

TOC

2 5/8"

3 1/2"

4 Holes >= 0.195"

3 15/16"

Cleared for #6 bolts

4 Holes >= 0.25"

Cleared for #10 bolts

Figure E

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

electromagnetic hid Ballasts
High Pressure Sodium
Input
Volts

Product
Number

Product Code

Circuit
Type

Nom.
Input Max Input
Open
Power
Current
Circuit
(Watts)
(Amps)
Volts

Fuse
Rating
(Amps)

2.10

6

Dimensions
Fig

A Max

B Max

Capacitor
Mfd Volts

Ignitor
(IGN/)

Kit Weight (lbs)
Total Ballast
Weight Weight

UL Bench
Top Rise

200 Watt HPS Lamp, ANSI Code S66
120
208
240

55118

S66/200CWA/4T/K

CWA

240

277

1.20
1.10

178

4
3

A
I

1.22

3.05

28

250

HPS2

9.21

A

7.60

A

0.90

3

A

2.50

7

A

250 Watt HPS Lamp, ANSI Code S50
120
208
240

55120

S50/250CWA/4T/K

CWA

300

1.50
1.30

185

4
4

I

1.85

3.50

35

240

HPS2

12.62

A

9.93

A

277

1.10

3

A

120

2.60

7

A

208

1.50

4

A

240

55122

S50/250CWA/5T/K

CWA

298

1.30

185

4

I

1.97

3.90

35

240

HPS2

13.60 10.70

A

277

1.10

3

A

480

0.60

2

A

120

3.80

10

A

208

2.20

7

400 Watt HPS Lamp, ANSI Code S51

240

55124

S51/400CWA/4T/K

CWA

453

277

1.90

182

5

I

2.32

4.18

55

240

HPS2

14.82 12.60

A
A

1.70

5

A

120

3.80

10

A

208

2.20

7

A

240

55126

S51/400CWA/5T/K

CWA

450

1.90

185

5

I

2.56

4.70

55

240

HPS2

17.37 13.70

A

277

1.60

5

A

480

0.90

3

A

Ballast Dimensions

B max

A max

4 1/4"
3 7/8"

4 3/8"
Figure I

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

4 3/4"

4 Holes >= 0.25"
Cleared for #10 bolts

TOC 243

Electromagnetic hid ballastS
High Pressure Sodium
Input
Volts

Product
Number

Product Code

Circuit
Type

Nom.
Input Max Input
Open
Power
Current
Circuit
(Watts)
(Amps)
Volts

Fuse
Rating
(Amps)

8.80

25

Capacitor

Dimensions
Fig

A Max

B Max

Mfd Volts

Ignitor
(IGN/)

Kit Weight (lbs)
Total Ballast
Weight Weight

UL Bench
Top Rise

1000 Watt HPS Lamp, ANSI Code S52
120
208
240

55128

S52/1000CWA/4T/K

CWA

1030

5.10
4.40

430

15
10

A
O

4.33

6.40

26

525

HPS3

30.50 26.00

A
A

277

3.90

10

A

120

9.70

25

A

208

5.60

15

A

240

55130

S52/1000CWA/5T/K

CWA

1070

4.90

430

12

O

4.1

6.10

26

525

HPS3

32.00 26.00

A

277

4.20

10

A

480

2.40

6

A

Ballast Dimensions
B max

A max

4 1/4"
3 7/8"

4 3/8"
Figure O

244

TOC

5 3/8"
6"

8 Holes >= 0.25"
Cleared for #10 bolts

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

electromagnetic hid BallastS
Capacitor Guide
Product
Number

Product Code

Halco Ballast Code

Mfd

Volts

Diam. (mm)

Diam. (in)

Height
(mm)

Height (in)

DRY FILM
55851

*CAP/MH50

M110/50HX/2T/K

6

280

35

1.38

48

1.89

55853

CAP/MH70

M98/70HX/4T/K

8

280

30

1.19

68

2.68

55855

CAP/MH100

M90/100HX/4T/K

12

280

30

1.19

78

3.08

55857

CAP/MH150

M102/150HX/4T/K

16

280

35

1.38

78

3.08

55859

CAP/MH175

10

400

35

1.38

78

3.08

55861

CAP/MH250

15

400

40

1.58

78

3.08

55871

CAP/MH250PS

18.5

330

35

1.38

78

3.08

55863

CAP/MH320PS

21

345

40

1.58

79

3.08

55865

CAP/MH350PS

22.5

345

40

1.58

78

3.08

55873

CAP/MH400PS

26

330

40

1.58

93

3.66

55868

CAP/MH400/DRY

24

400

45

1.77

93

3.66

55801

*CAP/HPS50/120

20

120

30

1.19

68

2.68

55803

CAP/HPS70/120

28

120

30

1.19

78

3.08

M57/175CWA/4T/K
M57/175CWA/5T/K
M58/250CWA/4T/K
M58/250CWA/5T/K
M138/250CWA/4T/K
M132/320CWA/4T/K
M132/320CWA/5T/K
M131/350CWA/4T/K
M131/350CWA/5T/K
M135/400CWA/4T/K
M135/400CWA/5T/K
M59/400/CWA/4T/K
S76/35R/120/K
S68/50R/120/K
S62/70R/120/K

55805

*CAP/HPS70

S62/70HX/4T/K

7

300

30

1.19

68

2.68

55807

*CAP/HPS100/120

S54/100R/120/K

46

120

40

1.58

68

2.68

55809

CAP/HPS100

S54/100HX/4T/K

10

280

30

1.19

78

3.08

55811

CAP/HPS150/120

S55/150R/120/K

55

120

40

1.58

78

3.08

55813

CAP/HPS150

S55/150HX/4T/K

14

280

35

1.38

78

3.08

55815

*CAP/HPS200

S66/200CWA/4T/K

28

240

40

1.58

68

2.68

35

280

40

1.58

78

3.08

24

400

45

1.78

83

3.27

24

480

50

1.97

103

4.06

55

240

50

1.97

103

4.06

26

525

50

1.97

104

5.63

55817

CAP/HPS250

S50/250CWA/4T/K
S50/250CWA/5T/K

OIL-FILLED
55867

CAP/MH400/OIL

55869

CAP/MH1000

55819

CAP/HPS400

55821

CAP/HPS1000

M59/400CWA/4T/K
M59/400CWA/5T/K
M47/1000CWA/4T/K
M47/1000CWA/5T/K
S51/400CWA/4T/K
S51/400CWA/5T/K
S52/1000CWA/4T/K
S52/1000CWA/5T/K

* Product will be discontinued when inventory is depleted

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 245

Electromagnetic hid ballastS
Ignitor Guide
Product Number

Product Code

Ballast

55907

IGN/MH1

35W - 150W PS MH

55909

IGN/MH2

175W-450W PS MH

55901

IGN/HPS1

35W - 150W HPS

55903

IGN/HPS2

200W - 400W HPS

55905

IGN/HPS3

1000W HPS

246

TOC

Diam. (mm)

Diam. (in)

Height (mm)

Height (in)

35.6

1.4

66.0

2.6

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

electromagnetic hid BallastS
Cross Reference Guide
ADVANCE

UNIVERSAL/
MAGNETEK

HOWARD

M102/150HX/4T/K

71A5492-001D

M150MLTLC3M500K

M0150-71C-512-K

M110/50HX/4T/K

71A5191-001D

M50MLTLC3M500K

M0050-23C-511-K

M141/1000CWA/4T/K

71A6593-001

P1000MLTAC5M500K

M1000-71C-612-K

M141/1000CWA/5T/K

71A6552-001D

P1000ML5AC5M500K

M1000-81C-611-K

M149/750CWA/4T/K

71A64F2-001D

P750MLTAC5M500K

M0750-71C-612-K

M149/750CWA/5T/K

71A6452-001D

P750ML5AC5M500K

M0750-81C-612-K

M131/350CWA/4T/K

71A5993-001D

P350MLTAC4M500K

M0350-71C-6E4-K

M131/350CWA/5T/K

71A5953-001D

P350ML5AC4M500K

-

M132/320CWA/4T/K

71A5892-001D

P320MLTAC4O500K

M0320-71C-6E4-K

M132/320CWA/5T/K

71A5852-001D

P320ML5AC4L500K

-

M135/400CWA/4T/K

71A6092-001D

P400MLTAC4L500K

M0400-71C-6E3-K

M135/400CWA/5T/K

-

P400ML5AC4M500K

-

M138/250CWA/4T/K

71A5792-001D

P250MLTAC4L500K

M0250-71C-611-K

M138/250CWA/5T/K

-

P250ML5AC4M500K

-

M150/125CWA/4T/K

-

-

-

M90/100HX/4T/K

71A5390-001D

M100MLTLC3M500K

M0100-71C-512-K

M98/70HX/4T/K

71A5292-001D

M70MLTLC3M500K

M0070-71C-511-K

M48/1500CWA/4T/K

71A6772-001D

M1500MLTAC5M500K

M1500-71C-214-K

M48/1500CWA/5T/K

-

-

-

M47/1000CWA/4T/K

71A6572-001

M1000MLTAC5M500K

M1000-71C-214-K

M47/1000CWA/5T/K

71A6552-001

M1000ML5AC5M500K

M1000-81C-213-K

M57/175CWA/4T/K

71A5570-001D

M175MLTAC3M500K

M0175-71C-214-K

M57/175CWA/5T/K

-

M175ML5AC3M500K

M0175-81C-214-K

M58/250CWA/4T/K

71A5771-001D

M250MLTAC3M500K

M0250-71C-215-K

M58/250CWA/5T/K

71A5750-001D

M250ML5AC3M500K

M0250-81C-215-K

M59/400CWA/4T/K

71A6071-001D

M400MLTAC4M500K

M0400-71C-213-K

M59/400CWA/5T/K

71A6051-001D

M400ML5AC4M500K

M0400-81C-212-K

HALCO
Pulse Start Metal Halide

Standard Metal Halide

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 247

Electromagnetic hid ballastS
Cross Reference Guide

ADVANCE

UNIVERSAL/
MAGNETEK

HOWARD

S50/250CWA/4T/K

71A8271-001D

S250MLTAC4M500K

S0250-71C-214-K

S50/250CWA/5T/K

71A8251-001D

S250ML5AC4M500K

S0250-81C-212-K

S51/400CWA/4T/K

71A8473-001D

S400MLTAC5M500K

S0400-71C-212-K

S51/400CWA/5T/K

71A8453-001D

S400ML5AC5M500K

S0400-81C-212-K

S52/1000CWA/4T/K

71A8773-001

S1000MLTAC5M500K

S1000-71C-212-K

S52/1000CWA/5T/K

71A8753-001

S1000ML5AC5M500K

S1000-81C-212-K

S54/100HX/4T/K

71A8071-001D

S100MLTLC3M500K

S0100-71C-512-K

S54/100R/120/K

71A8007-001DB

-

S0100-02C-111-K

S55/150HX/4T/K

71A8172-001D

S150MLTLC3M500K

S0150-71C-512-K

S55/150R/120/K

71A8107-001DB

-

S0150-02C-111-K

S62/70HX/4T/K

71A7971-001D

S70MLTLC3M500K

S0070-71C-512-K

S62/70R/120/K

71A7907-001DB

-

S0070-02C-111-K

S66/200CWA/4T/K

71A8970-001D

S200MLTAC4M500K

S0200-71U-211-K

S68/50R/120/K

71A7807-001DB

-

S0050-02C-111-K

S76/35R/120/K

71A7707-001DB

-

S0035-02C-111-K

HALCO
High Pressure Sodium

248

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

electromagnetic hid BallastS
Specifications
SPECIFICATIONS
Ballast shall be designed in accordance with all applicable ANSI specifications including
ANSI C82.4.
Ballast shall be designed with Class “H” (180°C) or higher insulation system.
All coils shall be precision wound.
Ballast shall operate for at least 180 cycles of 12 hours on and 12 hours off, when the lamp
circuit is in a short-circuited or open condition. This operation should cause no reduction in
ballast life.
Ballast and starter combinations shall operate reliably at starting temperatures of -40°C for
High Pressure Sodium ballasts and -30°C for Metal Halide ballasts.
Ballast shall not contain PCBs.
Manufacturer shall provide written warranty against defects in material or workmanship
for 2 years from date of manufacture.
Capacitors
All capacitors provided shall have a self-contained internal bleeder resistor.
All oil-filled capacitors shall have 0.25” quick disconnect terminals and be housed in
corrosion-resistant steel cans.
All required capacitors will be provided by the ballast manufacturer.
Ignitors
All ignitors will be epoxy-filled with a plastic external housing.
All ignitors shall be designed to provide six months of open circuit operation without failure.
Ballast shall have a lamp end-of-life detection and shut down circuit.
Ballast shall not contain PCBs.
Manufacturer shall provide written warranty against defects in material or workmanship
for 3 years from date of manufacture.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 249

APPENDIX
CONTENTS
251 How to Measure a Lamp
251 Filament Lamp Construction
252 Glossary of Terms
265 Lamp Warranty
266 Ballast Warranty

main
TOC

APPENDIX
How To Measure A Lamp


DIA.

DIA.











MOL

MOL

LCL



 

DIA: The diameter of a bulb at its widest point,
measured in eighths of an inch.
MOL: Maximum Overall Length from the top of
the bulb to the bottom of the base, measured
in inches.
LCL: Distance from the center of the light
source to the bottom of the base, measured
in inches.

Filament Lamp Construction
Special chemicals are applied
inside lamp and on the filament to
protect against premature failure.

Long life lamps utilize five filament
supports to enhance longevity and
guard against filament sagging and
breakage.

H

G Long life lamps utilize long,

F

thick coiled filaments.

C Stem type is matched to lamp
Argon and Nitrogen gases are
used for washing and filling lamps.

D

type to enable exact positioning of filament.

B Tempered glass stem provides
strength and durability.

Lamp bases made with brass A
or nickel-plated brass do not
freeze or corrode in the socket.

E Fused lead - wire carries electricity
from the base to the filament and
guards against potential fire hazards.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 251

APPENDIX
Glossary of Terms
2-Tap: HID ballast that operates at two input voltages:
120, 277.
4-Tap: HID ballast that operates at four input voltages:
120, 208, 240, 277.
5-Tap: HID ballast that operates at five input voltages:
120, 208, 240, 277, 480.
Accent Lighting: Directional lighting used to highlight a
particular object or area.
Acoustic Resonance: A phenomenon that can occur when
using electronic ballast that operates at a high frequency
with a high intensity discharge lamp. What can happen is the
frequency of the ballast creates a harmonic in the lamp, causing
distortion of the arc and subsequent vibration of the arc tube.
This is most common in metal halide and ceramic discharge
metal halide lamps, and is less of a problem for high pressure
sodium. It is for this reason most electronic metal halide ballasts
are low frequency square wave ballasts as the lower frequency
avoids this problem.
Alternating Current (AC): Electron flow that periodically
reverses polarity and direction of travel through a circuit.
Ambient Lighting: The overall general lighting in an area or
room.
Ambient Temperature: Refers to the temperature of the air
around the device specified.
Ampere (amp): A standard unit of measurement of electrical
current. Amps = Watts / Voltage
ANSI (American National Standards Institute): The
organization that develops voluntary guidelines and product
performance standards for the electrical and other industries.
ANSI Ballast Type: A reference to the ANSI document which
describes the lamp and lists the characteristics of the ballast
required to operate the lamp. For HID lamps this is a code
with a letter prefix followed by numbers. The following naming
system is used:
H – mercury lamps; M – metal halide lamps; S – high pressure
sodium lamps; L – low pressure sodium lamps. ANSI codes
must match for a lamp and ballast to be compatible.
ANSI Lamp Codes: These are 3-letter codes assigned by the
American National Standards Institute. They provide a system
of assuring mechanical and electrical interchangeability among
similarly coded lamps from various manufacturers. Often found
in halogen lamps.
Arc: Intense luminous discharge formed by the passage of
electric current across a distance between electrodes.

252

TOC

Arc Tube: A completely sealed quartz or ceramic tube where
an electrical arc occurs and generates light.
Argon: Inert gas used in incandescent and fluorescent lamp
types. In incandescent light sources, argon retards evaporation
of the filament.
Auto-Transformer: A type of transformer that electrically
connects the primary and secondary coils. This type of circuit
is used to make many ballasts smaller and more efficient.
Average Rated Life: An average rating, in hours, indicating
when 50% of a large group of lamps have failed, when operated
at nominal lamp voltage and current. Manufacturers use 3
hours per start for fluorescent lamps and 10 hours per start
for HID lamps when performing lamp life testing procedures.
Every lamp type has a unique mortality curve that depicts its
average rated life.
Ballast: A device used to obtain the necessary circuit conditions
(voltage, current and waveform) for starting and operating an
electric-discharge lamp. All fluorescent and HID light sources
require a ballast for proper operation.
Ballast Case Temperature: Used as a reference point in
design, temperature of ballast in situation when measured at
the ballast hot spot. See Maximum Case
Temperature.
Ballast Cycling: Intermittent operation due to high temperature
condition of the ballast or ambient temperature, which causes
the thermal protector to open and turn off the ballast. After
cooling down, the thermal protector closes, turning on the
ballast and starts the heating cycle over again. This is different
from lamp cycling, which is caused by voltage rise in a lampreaching end of life.
Ballast Efficacy Factor (BEF): The ratio of a ballasts’ light
output to input power. Useful for comparing the efficiency of two
different ballasts on a light output to power consumption basis.
BEF =% Ballast Factor/Input Power (Watts)
Ballast Factor (BF): The measured ability of a particular ballast
to produce light from the lamp(s) it powers. Ballast factor is
derived by dividing the lumen output of a particular lamp/
ballast combination by the lumen output of the same lamp(s)
on a reference ballast.
Ballast Hot Spot: The measurement point on a ballast that is
the highest temperature point during normal operation, and is
used in design when referencing the ballast case temperature
and maximum case temperature.
Ballast Kit: A kit developed to include all necessary parts for
the installation of a new ballast. For HID ballast kits this includes:
ballast, capacitor, ignitor (if used) and all necessary mounting
hardware. For CFL kits this includes: ballast, mounting plate,
lead wire set, wire-removal tool and mounting hardware.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com

APPENDIX
Glossary of Terms
Ballast Loss: The total power lost in the operation of the ballast
measured in watts. This power is given off as heat energy. It is
equivalent to the difference between the input power and the
lamp wattage.
Base: The base holds the lamp in place in the fixture and
conducts electricity from the circuit to the lamp. It can be
designed to dissipate heat.
Beam Angle: The angle of the cone of light emitted from a
light source or luminaire. This is often used to describe the light
distribution of a reflectorized lamp (such as R and PAR types)
or an LED replacement product and encompasses the central
part of the beam out to the angle where the intensity is 50% of
the maximum. This is referred to in degrees. The beam angle
(sometimes called “beam spread”) is often part of the ordering
code for reflectorized lamps. See also field angle.
Beam Spread: See Beam Angle.
Binning: A systematic process of dividing LEDs into smaller
subgroups with a similar brightness and chromaticity
distributions. Halco minimizes color variation by utilizing binning
for LEDs used in ProLED lamps at +/- 200K.
Bi-Pin – Fluorescent: A lamp design utilizing two pins on
each end of a fluorescent lamp tube. This is crucial to provide
cathode heating voltage between the two pins for rapid start
and programmed start operations. These lamp can also be used
on instant start ballasts that are rated to run them.

Candela: The measure of luminous intensity of a source
in a given direction. The term has been retained from early
lighting sciences when a standard candle of a fixed size and
composition was defined as producing one candela in every
direction. A plot of intensity versus direction is called a candela
distribution curve and is often provided for directional lamps
and luminaires with a lamp operating in them.
Candelabra base: Small screw base for lamps, also known
as an E12 base.
Candlepower: Obsolete term for luminous intensity,
see Candela.
Candlepower Distribution: The candlepower at various angles
from a light source show in a numerical table and in a graph
known as the luminous intensity distribution curve. This data
can be found in photometric reports and is used to understand
how the light source will illuminate the area being lit.
Capacitor: A device that can be used to store energy in an
electric circuit. This is done via an electric field between two
closely spaced conductors.
Cathode: Tungsten filaments that emit electrons in a fluorescent
lamp, and are often coated in an emissive material to assist
in starting. Negatively charged free electrons emitted by the
cathode are attracted to the positive electrode (anode), creating
an electric current between the two electrodes, generating the
UV that is converted into visible light by the phosphor.

Bi-Pin-Halogen or Incandescent: A lamp design using two
pins rather than a screw in or twist lock base to provide power
to heat the filament. Most often used in low voltage lighting
for JC halogen capsules and MR-type lamps, there are line
voltage versions.

Cathode Guard: Metal band encircling the cathode of a
fluorescent lamp, used to collect the evaporating particles from
the cathode, greatly reducing end-blackening.

Black Body (Planckian radiator): A theoretical ideal thermal
radiator whose SPD curve is defined by its temperature in Kelvin
and whose color coordinates lie exactly on the Planckian curve.
Tungsten lamps (both incandescent and halogen) are close
enough to be considered blackbodies for the purpose of SPD.

CDMH: See Ceramic Discharge Metal Halide.

Bottom Exit: A configuration with leads or a wire-trap on the
bottom or base of the ballast.

Ceramic Discharge Metal Halide: A type of metal halide
discharge lamp that uses a translucent alumina (ceramic)
material for the arc tube instead of glass quartz. This material
is stronger and has higher heat and chemical tolerances than
quartz, allowing a different chemical mix to be used which
results in better color rendering (>80 CRI) and improved
lumen maintenance without sacrificing efficacy. Halco ceramic
discharge metal halide lamps feature a 1-piece arc tube design
that delivers excellent color consistency and lamp reliability.
Also known as Ceramic Metal Halide, CDM, CMH or CDMH.

BR Lamp: BR is a term for Bulged Reflector, and refers to a
shape of blown glass reflector lamps with a “stepped” reflector
for better light extraction.
Canadian Energy Standards: Note on label that indicates that
the ballast complies with the Canadian Energy Standards and
meets the requirements of CAN/CSA-C654-M91.

CDM: See Ceramic Discharge Metal Halide.

Center Beam Candlepower (CBCP): Refers to the luminous
intensity at the center of the beam of a reflector lamp; measured
in candelas.

Canadian Standards Association (CSA): An association that
generates product performance and safety standards for many
Canadian industries.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 253

APPENDIX
Glossary of Terms
Ceramic Metal Halide: See Ceramic Discharge Metal Halide.
Chip: A very small square of semi-conducting material that is the
active light-emitting component of an LED. Also known as a die.
Chromaticity: The aspect of color that includes consideration
of its dominant wavelength and purity and is typically described
as a pair of coordinates on a color space.
CIE: Commission Internationale De L’Eclairage (International
Commission on Illumination): abbreviated as CIE from its French
title, is an organization devoted to international all matters
relating to the science and art of lighting.
Class H: An operating temperature classification for electrical
components established by Underwriters Laboratories. Allows
operation up to 180°C.
Class P: A classification for thermally protected ballasts
established by Underwriters Laboratories. In Class P ballasts,
internal thermal cutoff removes the input power when the
specified temperature limits are exceeded.
CMH: See Ceramic Discharge Metal Halide.
Coefficient of Utilization (CU): The fraction of initial lamp
lumens that reach the work plane. It is a function of luminaire
efficiency, room surface reflectance, and room shape.
Coil: Windings of copper or aluminum wire around the core in
electromagnetic ballast that transforms the voltage from input
to output.
Color Corrected: Refers to a lamp with a special phosphor
or coating to give it a color rendering profile similar to natural
daylight.
Color Rendering Index (CRI): A measurement to rate a lamp’s
ability to render an object’s color on a scale of 0-100, the higher
the CRI, the more true to life colors appear, as they would in
natural daylight.
Color Spectrum: The visible light spectrum, ranging between
380 (violet) and 770 (red) nanometers in the electromagnetic
spectrum.
Color Temperature: The actual color of a light source, also
referred to as Correlated Color Temperature (CCT), measured
in degrees Kelvin (K). Typical color temperature is:
2700K Incandescent/Fluorescent - Warm White
3000K Halogen/Fluorescent - Soft White
3500K Fluorescent - White
4100K Fluorescent - Cool White
5000K Fluorescent - Natural White
6500K Fluorescent - Daylight

254

TOC

Compact Fluorescent Lamp: A small, fluorescent lamp, often
used as an alternative to incandescent lighting, that utilizes
small diameter tubes that are bent so that they begin and end
in a single base. The lamp life is about 10 times longer than
incandescent lamps and is 3-4 times more efficacious.
Consortium for Energy Efficiency (CEE): An organization that
qualifies and promotes energy efficiency products including high
performance and reduced wattage linear fluorescent lamps
and ballasts. A growing number of utility programs across the
U.S. offer rebates for commercial and industrial customers that
purchase and install CEE listed T8 lamps and ballasts in new
construction, replacement and retrofit projects.
Constant Current Driver: A current and voltage regulating
power supply often used to power LEDs. This methodology
produces more consistent color and helps maintain the life and
light of LEDs when used in a lighting device.
Constant Voltage Driver: A power supply that provides a
constant voltage (usually DC) to a device, and is often used to
power LED devices. This is more commonly used in LED string
or strip type devices.
Constant Wattage Auto-Transformer (CWA): A type of HID
ballast reactor that applies a constant wattage to the lamp and
uses an auto-transformer to step-up the voltage.
Cool White: A term commercially used to describe a color
temperature of around 4100K generated by a halophosphor
type fluorescent lamp. The Cool White(CW) designation is used
most often for T12 lamps but also for other fluorescent lamps
using halophosphors and having a CRI of approximately 62.
These types of lamp are falling out of favor for more efficient
Tri-Phosphor lamps. Cool White is also used to describe selfballasted CFLs with a color temperature of 4100K.
Core: A component of an electromagnetic ballast, which is
surrounded by the coil. Core is composed of steel laminations
or a solid ferrite material.
Core and Coil Ballast: Another term for an electromagnetic
ballast.
Cove Lighting: Refers to light sources mounted above a ledge
or in a recess that distribute light upward for ambient lighting.
CoverShield: A safety coated Halco lamp that is protected
against rupture if it is dropped, struck or experiences thermal
shock. Often used for food service, daycare and medical
facilities.
Crest Factor (Lamp Current Crest Factor): The ratio of the
peak lamp current to RMS or average lamp operating current.
High current crest factors are detrimental to lamp life and
performance. ANSI standard for lamp current crest factor is
<1.7.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com

APPENDIX
Glossary of Terms
CSA: Canadian Standards Association. An association that
generates product performance and safety standards for many
Canadian industries.

Double-Ended Lamp: Lamps that have two bases or points
of electrical connection that provide extra stability in rough
service applications.

cUL: Approval from Underwriters Laboratories for use in
Canada.

Down Lighting: A direct lighting unit, usually small, that aims
the light downward. Can be recessed, surface mounted or
suspended.

Current: A measure of the rate of flow of electricity, expressed
in amperes (A).
Cycling: This is used to describe a condition where a lamp will
turn on for a short period, then turn off for a period of time, and
then restart (starting the cycle over again). This is a common
end-of-life occurrence in High Pressure Sodium lamps, but
can be present in other types of HID lamps. For HID lamps this
occurs when the operating voltage of the lamp rises beyond
the ballast’s ability during warm-up, which causes the lamp to
shut down, and restart after it has cooled. In other situations, it
can be caused by an overheating situation where a temperature
sensor in either a lamp or fixture shuts off power when the
ambient temperature gets too hot.
Daylight: A term used to describe a high correlated color
temperature light that has an appearance roughly equal to that
of midday sun, having a CCT of approximately 6500K. This type
of light typically provides very good contrast, but is considered
to have a “cold” and sometimes “harsh” feel.
Dedicated Voltage: A ballast designed to work on one specific
input voltage.
Design Amperes: The approximate current that the lamp will
draw at design voltage.
Design Lumens: Lumen value at 40% of rated average life.
Also called Mean Lumens.
Dichroic: A type of reflector that is designed to allow infrared
waves to pass but reflect the visible spectrum of light. Often
used on MR lamps, this is designed to provide a “cooler” beam
and have less direct infrared hitting the illuminated surface.
Die: See Chip.
Diffusion: The even redirection or spreading of light by a lens
or diffuser.
Diode: Typically a semiconductor that is a two-electrode device
with an anode and a cathode that passes current in only one
direction. It may be designed as an electron tube.
Directional Lighting: Illumination on the workplane or on an
object predominantly from a single direction.
Discharge Lamp: A light source that produces light by passing
a current between electrodes through a vapor or gas. Includes
fluorescent and high intensity discharge lamps.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Driver: A power supply that is used to power LEDs in a device.
Essentially serves the same purpose as a ballast, but for LEDs.
Dual Connection: A CFL ballast with both side and bottom
exits for the lead wires, allowing use for multiple applications
.
Dual Inline Package: Also known as DIP, this is a packaging
method for LEDs that the LED is located in a small reflector,
and then totally encased in a transparent or colored plastic.
The heat is dissipated through the electrical pins, but is far less
effective at heat dissipation than an SMD package, limiting total
power dissipation potential and increasing lumen depreciation
rates significantly.
Eco-Shield: Halco brand linear fluorescent lamps that are
TCLP compliant due to their low mercury content and other
design features intended to prevent mercury from escaping
disposed of lamps.
Efficacy: The measure of lumen output per unit power supplied
to the product. Useful as a measurement of how effective the
light source is in converting electrical energy to lumens of
visible light. Expressed in lumens-per-watt (LPW), this measure
gives more weight to the yellow region of the spectrum and
less weight to the blue and red regions where the eye is not as
sensitive (also known as the photopic response curve).
Efficiency: The efficiency of a light source is simply the fraction
of electrical energy converted to light, i.e. watts of visible light
produced for each watt of electrical power with no concern
about the wavelength where the energy is being radiated.
For example, a 100-watt incandescent lamp converts 7% of
the electrical energy into light; discharge lamps convert 25%
to 40% into light. The efficiency of a luminaire or fixture is the
percentage of the lamp lumens that actually comes out of the
fixture. Efficiency can also refer to a ballast or driver, and refers
to the ratio of power supplied to the lamp or LED to the input
power of the ballast or driver.
Electrical Discharge: A gas electrically conducting and
transmitting current, usually accompanied by the emission
of visible and other radiation. This is a principle behind many
energy saving technologies.
Electrode: An electrical conductor through which current enters
or leaves a medium such as an arc tube or gas filled lamp.
Electromagnetic Ballast: A low-frequency ballast that
operates through the use of current carrying coils assembled
on a magnetic core.
TOC 255

APPENDIX
Glossary of Terms
Electromagnetic Spectrum: A continuum of electric and
magnetic radiation that can be characterized by wavelength or
frequency, encompassing a wide range of energies from infrared
to visible to gamma rays. Visible light encompasses a small part
of the electromagnetic spectrum in the region from about 380
nanometers (violet) to 770 nanometers (red) by wavelength.
Electronic Ballast: A ballast that uses semiconductor
components to increase the frequency of fluorescent lamp
operation (typically in the 20-40 kHz range). Smaller inductive
components provide the lamp current control. Fluorescent
system efficiency is increased due to high frequency lamp
operation. Results are increased lamp efficacy, reduced ballast
losses and lighter, smaller ballasts compared to electromagnetic
ballasts. Electronic ballasts may also be used with HID (high
intensity discharge) lamps.
Electronic Component: A device or part employed in an
electronic circuit to obtain some desired electronic action.
Electronic Transformer: A device for converting electricity from
one voltage to another voltage that is comprised of electrical
components. This type of transformer changes the frequency
of power to the lamp, and often operates at over 20kHz. These
devices tend to be smaller and more efficient than magnetic
transformers but often have minimum load ratings that must
be met for use. These can have compatibility issues with other
electrical devices such as LED lamps.
Elliptical Reflector: Incandescent lamp with a reflector shell
that is elliptically shaped. Focuses light immediately in front of
the lamp, which reduces absorption and increases efficiency.
EMI/RFI: Electromagnetic Interference or Radio Frequency
Interference. Unintentionally generated power during the
operation of a ballast that is capable of interfering with other
electrical devices operating at high frequencies.
End Blackening: Darkening around the ends of a fluorescent
tube caused by particles evaporating from the cathode and
adhering to the glass. Lamps made with cathode guards greatly
reduce this occurrence.
End-of-Life (EOL) Protection: Circuit in a compact fluorescent
ballast that removes power supply to the lamp during abnormal
lamp end-of-life. Ballast will reset when a new lamp is installed.
Energy: A measure of work done by an electrical system over
a given period of time; measured in kilowatt-hours (kWh).
Energy Policy Act (EPACT): Energy legislation originally passed
by Congress in 1992, and updated periodically, mandating
labeling and minimum energy efficiency requirements for many
commonly used incandescent and fluorescent lamps.

256

TOC

Energy Star ® : U.S. Department of Energy (DOE) and
Environmental Protection Agency (EPA) administered program
that provides designation for certain products meeting energy
efficiency and performance standards.
Energy Survey: Systematic cost comparison of an existing
system to a proposed system, accounting for electrical,
material, maintenance and labor costs.
EOL Protection Circuit: For all T5 and smaller lamps, there is a
circuit that monitors the operating parameters within the ballast
that, when normal operations are exceeded, will shutdown the
ballast.
Etch: Markings on the glass envelope or shell of a lamp
designating product description, logo and/or brand name.
Exclusionary Mogul Base: A variant of a mogul base designed
to prevent enclosed rated lamps from being used in an open
rated fixture, which is also known as an EX39 base. This base
is only used in open-rated metal halide lamps and has the
bottom electrical contact protruding that allows the lamp to
make contact with the recessed electrical contact within the
exclusionary socket. The socket is pink in color to denote the
difference and help prevent confusion, as enclosed rated metal
halide lamps will not operate in this socket.
Exitance: The total light that comes off of a surface. Exitance
is dependent upon the illuminance on and reflectance off the
surface.
Extended Life (XL): Suffix for ProLume T5 and T8 lamps
with special cathode design and phosphors that provide
40,000 hours average rated life when operated with an instant
start ballast and up-to 46,000 hours when operated with a
programmed start ballast.
Eyeball: Fixture, usually recessed, which can be rotated to
point in a desired direction.
Field Angle: The light distribution cone from directional light
sources encompassing the central part of the beam out to the
angle where the intensity is 10% of maximum. See also Beam
Angle.
Filament: Wire used in incandescent lamps, usually made of
tungsten and often coiled, that emits light when heated by an
electrical current.
Fixture: Luminaire without lamps.
Floodlight: A reflector lamp designed to produce a broad,
relatively diffused beam of light.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

APPENDIX
Glossary of Terms
Fluorescence: The emission of electromagnetic radiation light by
a substance that has absorbed radiation of a different wavelength.
In most cases, absorption of light of a certain wavelength induces
the emission of light with a larger wavelength (and lower energy).
Fluorescence can be either wide-band (emitting a wide range
of wavelengths such as halophosphors or LED phosphors) or
very narrow (such as those used in a tri-phosphor lamp).
Fluorescent Lamp: A glass tube coated on the inside with
a fluorescent substance that gives off light when a stream of
electrons from the cathode excites mercury vapor in the tube.
Flux: The basic measure of light flow that includes only visible
light and is weighted to match the response of the human eye;
measured in lumens.
Footcandle (fc): A unit measurement of direct illumination.
One footcandle is equal to one lumen per square foot.
Frequency: A measurement of the number of cycles per
second; the SI base unit is Hertz (Hz).
Full Spectrum: Broad spectrum light source capable of
producing colors throughout the entire range of the visible
spectrum, simulating actual sunlight.
General Lighting: Uniform light throughout an area, with no
special provisions for task lighting or accent lighting.

Grounding: The connection of an electrical component that is
a conductor to “ground” or earth so that the electrical current
can pass off to it. A ballast or power supply with a ground input
or a metal housing should always be grounded. The grounding
helps assure safety and acceptable EMI/RFI performance.
Halogen Cycle: A regenerative cycle of tungsten and halogen
atoms, which prevents blackening of the lamp envelope during
the life of the lamp.
Halogen Lamp: An incandescent lamp with a filament that
is surrounded by halogen gases. Halogen gases allow the
filaments to be operated at higher temperatures and higher
efficacies.
HaloXen: A Halco product line utilizing a halogen/xenon gas
mixture and specially designed filaments that produces a
higher degree of energy efficiency than standard incandescent
and halogen lamps. The heavier xenon gas reduces filament
evaporation and increases light output, while the halogen gas
maintains a clear glass wall and redeposits evaporated tungsten
back onto the filament, extending the lamp life and allowing
greater energy efficiency.
Harmonic Distortion: Distortion of an AC waveform caused
by multiples of the fundamental frequency.
Head: Luminaire for a track-lighting system.

Glare: An interference with visual perception caused by an
uncomfortably bright light source or reflection within one’s
field of view.

Hertz: A unit of frequency denoted as Hz. One Hz is equivalent
to one cycle per second. Can also be measured in kHz, or one
thousand cycles per second.

Grounded Plane: Linear fluorescent lamps must be within
a certain distance of a grounded metal plane with a width at
least the diameter of the lamp or 1 inch, whichever is greater.
This plane acts as a starting aid to the lamps and is important
to starting operations. The maximum distance between the
bulb wall and the starting aid (grounded plane) is as follows
per ANSI C78.81-2010:

High Ballast Factor: Ballast with a nominal ballast factor of
above 1.0, and typically ends up approximately 1.18 for T8
lamps.

Type of Fluorescent Lamp

High Lumen (HL): Suffix for ProLume F32T8 lamps that
produce more light than standard lamps without consuming
additional power through the use of special phosphors. Often
used in conjunction with a low ballast factor ballast to provide
energy savings with minimal light loss.

T5 Linear Lamps

Maximum Distance
Inch
mm
¼ (0.25)
6

T8 Linear Lamps

¾ (0.75)

19

Other 500mA or less

½ (0.5)

13

1

25

Other greater than 500mA

High Intensity Discharge (HID) Lamp: Metal Halide, High
Pressure Sodium, Low Pressure Sodium and Mercury Vapor
lamp types.

High Output Fluorescent (HO): Fluorescent lamps designed to
be used with an 800 milliampere ballast. Able to operate at low
temperatures (down to 0°F) and still produce high light levels.
High Power Factor: A power factor above 0.90 or 90%.
High Power LED: Generally defined as a packaged light
emitting diode that consumes 1W or greater. See Light Emitting
Diode.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 257

APPENDIX
Glossary of Terms
High Pressure Sodium (HPS) Lamp: High intensity discharge
light sources which produce light by an electrical discharge
through sodium vapor operating at relatively high pressures
and temperatures.
High Voltage: Voltages of 208 or higher.
High Wattage CFLs (or Spirals): Higher power compact
fluorescent lamps (65, 85, 105, 150 and 180 watts are
common power levels) which are used to replace high wattage
incandescent lamps or low wattage metal halide lamps (by
removing the ballast). These lamps are found in mogul and
medium base and typically have a long life.
HO (High Output): A lamp or ballast that operates at 800mA
is considered high output.
Hot Restrike Time: If there is a momentary power interruption
or the lights are turned off causing the HID lamp goes out, there
will be a delay of 3 to 15 minutes (depending on lamp type)
before the lamp has cooled down sufficiently to start again.
HX-HPF: A high reactance auto-transformer that operates at a
high power factor. A type of circuit used in HID ballasts.
HX-NPF: A high reactance auto-transformer that operates at
a normal power factor. A type of circuit used in HID ballasts.

InGaN: The main LED semiconductor technology containing
Indium, Gallium and Nitrogen to produce green, blue and
white-colored (with the help of phosphors) LED light sources.
Initial Lumens: The measured luminous output of a new light
source.
Input Voltage: Voltage required from a power supply for proper
operation of a ballast.
Input Watts: The total power input to the ballast which includes
lamp watts and ballast losses.
Instant Start: A type of fluorescent lamp-ballast circuit designed
to start fluorescent lamps as soon as the power is applied.
Originally, instant-start circuits were developed to eliminate
separate mechanical starter devices. Slimline fluorescent lamps
operate only on instant start circuits.
Integrated Lamp: Generally refers to a non-incandescent
lamp with the ballast or driver integrated into the lamp shape
and capable of running on line or low voltage. A screw-based
compact fluorescent lamp is an example of this.
Intensity: The light emitted from a source. Intensity varies given
the direction at which one views the source. Intensity does not
vary with distance.

Ignitor: An electronic device providing a high voltage pulse
from 3000V to 6000V (depending on the ballast) to initiate an
electrical discharge in a gas filled tube. Typically, the ignitor is
paired with or is a part of the ballast. See also starter.

Intermediate Base: Small screw base for lamps, also known
as an E17 base.

Illuminance: Light arriving at a surface, expressed in lumens
per unit area; 1 lumen per square foot equals 1 footcandle,
while 1 lumen per square meter equals 1 lux.

Kelvins: Base unit for measuring color temperature, used in
lighting to describe appearance of light. See Color Temperature.

Illumination: The result of the use of light.
Incandescent Lamp: A light source that produces light by the
heating of a filament by an electric current.
Inches to Millimeters Conversion: To calculate the metric
equivalent of inches in millimeters (mm), multiply inches by 25.4.
Indirect Lighting: Luminaires that distribute 90 - 100 percent
of their light upward to be reflected by the ceiling.
Induction Lighting: A means of lighting, which uses
RF induction of radio waves or microwaves to produce
luminescence. Induction lamps have no electrodes inside the
chamber and generally, therefore, have longer life than standard
incandescent lamps.
Infrared: Radiant energy in the wavelength range of about 770
to 1100 nanometers (nm). Energy in this range is not visible
to the naked eye, but can be sensed by the skin. Applications
include heat lamps, photography, medical therapy and industry.
258

TOC

Kelvin Temperature: See Color Temperature.

Kilowatt (kw): A measure of electrical power equal to 1000
watts.
Kilowatt Hour (kwh): The standard measurement of electrical
energy consumption. One kilowatt hour is equal to one kilowatt
of electricity used over the period of one hour. Also the typical
billing unit used by electrical utilities.
Krypton: A heavy inert gas used in incandescent lamps which
allows the filament to glow hotter and brighter and last longer.
L70 rating: The point at which a light source has depreciated
to 70% of the initial light output. This is commonly used as a
lifetime reference in LED lamps and fixtures.
Lamp: Lighting industry term used for a light bulb.
Lamp Dimensions: Bulb designations consist of a letter(s)
to indicate shape and a number to indicate the diameter in
eighths of an inch.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

APPENDIX
Glossary of Terms
Luminaire: A complete lighting unit including lamps, housing,
lens and ballast if required. All the necessary components to
make what we commonly refer to as a “fixture”.
Luminaire Efficiency: The ratio of total lumens exiting a luminaire
to those emitted by the lamp (or lamps) used in that luminaire.

Mean Spherical Candlepower (MSCP): The method of
rating the total light output of miniature lamps and the average
luminous intensity of an incandescent lamp in all directions.
MSCP can be converted to lumens by multiplying the MSCP
x 12.57.

Luminaire Efficiency: The ratio of total lumens exiting a
luminaire to those emitted by the lamp (or lamps) used in that
luminaire.

Medium Base: The common term for an E26 screw base for
a lamp.

Luminance (L): Light reflected in a particular direction; the
photometric quantity most closely associated with brightness
perception, measured in units of luminous intensity (candelas)
per unit area (square feet or square meters).
Luminous Efficacy: The light output of a light source divided
by total input power of the source. See Lumens per Watt.
Lux (lx): A unit of illuminance equal to 1 lumen per square meter.
Magnetic Ballast: A ballast used with discharge lamps
consisting of conductive windings of copper or aluminum
around a steel or iron core. This type of ballast is similar in
construction to magnetic transformers, and does not have
any impact on the frequency of the lamp. In general these
ballasts are less efficient but more tolerant of temperatures than
electronic ballasts. See also Electromagnetic Ballasts.
Magnetic Transformer: A device for converting electricity from
one voltage to another voltage that is comprised of conductive
windings of copper or aluminum around a steel or iron core. This
type of transformer does not change the frequency of power
to the lamp. In general these transformers are less efficient but
more tolerant of temperatures than electronic transformers.
Maximum Case Temperature: This is the maximum
temperature when measured at the ballast “hot spot” that
can be maintained and not impact the life or performance
of a ballast negatively. Beyond this point the ballast will be
significantly impacted and can have a short life and impact
lamp performance.
Maximum Overall Diameter (MOD): Maximum width or
diameter of a lamp taken on a plant perpendicular to the base
of the lamp. For most lamps this is referred to in a lamp’s
shape in 1/8” increments (ex. An A19 lamp is 19/8 inches in
diameter, or 2.375” diameter, and a T8 lamp is 8/8 inches in
diameter, or 1” in diameter). This measure becomes helpful in
determining fit for CFL spirals, which do not typically follow this
naming convention.
Maximum Overall Length (MOL): The overall length of a lamp,
from the top of the shell to the bottom of the base.
Mean Lumens: The measured output of a light source at 40%
of lamp life. Also called design lumens.

260

TOC

Mercury Vapor Lamp: A high intensity discharge light source
operating at a relatively high pressure (about 1 atmosphere) and
temperature in which most of the light is produced by radiation
from excited mercury vapor. Phosphor coatings on some lamp
types add additional light and improve color rendering.
Metal Halide Lamp: A high intensity light source in which the
light is produced by the radiation from mercury, plus halides
or metals such as sodium, scandium, indium and dysprosium.
Some lamp types may also utilize phosphor coatings.
Miniature Candelabra Base: Small screw base for lamps also
known as an E11 base.
Mini-Can: Usually refers to a line voltage halogen lamp with a
miniature candelabra base. See Miniature Candelabra Base.
Minimum Starting Temperature: References the minimum
ambient temperature that the ballast will reliably start a lamp.
Mogul Base: Large lamp base typically used for high power
incandescent, compact fluorescent, and high intensity
discharge type lights, also known as an E39 base.
Multi-Volt: A fluorescent electronic ballast that has a universal
input voltage; typically these ballasts have an acceptable input
voltage range of 108V to 305V.
Nanometer: A unit of length equal to 10-9 meters; commonly
used as a unit of wavelength.
National Electric Code (NEC): A nationally accepted electrical
installation code to reduce the risk of fire, developed by the
National Fire Protection Association.
National Electrical Manufacturers Association (NEMA):
Trade organization represented by around 450 manufacturers
of electrical supplies. NEMA develops product design,
manufacturing and performance standards that are designed
to benefit manufacturers and consumers alike.
Natural White: A term to describe fluorescent lamp that has
a high correlated color temperature, typically around 5000K.
This color temperature tends to be perceived as brighter but
somewhat harsher.
NEMA Premium Ballast: Designation that recognizes the
lighting industry’s most energy efficient T8 ballasts available.
Qualifying ballasts carry the NEMA Premium mark on the label.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com

APPENDIX
Glossary of Terms
Neodymium: A rare earth element used to produce full
spectrum incandescent lamps; also know as daylight or natural
light. They use a colored glass shell to filter out the yellow light
produced by standard incandescent lamps.
Nominal Input Voltage: The input voltage at which the ballast
is designed to operate. The nominal voltage allows for normal
levels of variation without affecting ballast operation.
Nominal Length: A measurement for Fluorescent lamp length
based on the length of the lamp plus an allowance for the
luminaire’s lamp holders.
Nominal Open Circuit Voltage (OCV): The rated open circuit
voltage for a ballast, typically at the center of an acceptable
range for this ballast.
Normal Ballast Factor: Ballast with a nominal ballast factor of
between 0.80 and 1.00, and typically ends up approximately
0.88 for T8 lamps.
Normal Power Factor: A power factor below 0.90 or 90%.
Typically low power factor ballasts operate at <0.50 or <50%.
Ohm’s Law: A scientific law which states that current
(amperes) in a circuit depends on resistance (ohms) and
applied electromotive force (volts). Current (I) = Voltage (E) /
Resistance (R)
Open Circuit Voltage (OCV): Open Circuit Voltage measured
across the socket the lamp screws into, with the ballast powered
on. This can be difficult to measure in modern products with end
of life protection, and is often dangerous to measure without
appropriate knowledge of the ballast. Exceedingly high voltages
could be present in certain types of lighting products.
Operating Position: Lamps may be operated in any position
unless otherwise noted.
Operating Voltage: For electrical discharge lamps, this is
the voltage measured across the discharge when the lamp is
operating. It is governed by the contents of the chamber and is
somewhat independent of the ballast and other external factors
but still must fall within predetermined characteristics in order
to be compatible with the ballast.
PAR Lamp: PAR is an acronym for parabolic aluminized
reflector. A PAR lamp, which may utilize either an incandescent
filament, a halogen filament tube or an HID arc tube, is a
precision pressed-glass reflector lamp. PAR lamps rely on both
the internal reflector and prisms in the lens for the control of
the light beam.
Parallel: A type of circuit in which the electrical pathway splits
and flows to each lamp simultaneously. In this type of circuit
each lamp is operated independently and therefore will continue
to operate even if the other lamp fails.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com

PCB (Polychlorinated Biphenyls): Chemical pollutant formerly
used in ballast capacitors that were part of ballasts. It is now
illegal to use PCBs and most such ballasts have been replaced
over time. No Halco ballasts have ever been produced with
PCBs.
Phosphor: A chemical compound typically found as a
powder that is deposited inside of the glass of a lamp, into the
encapsulent of a white LED, or applied over the emitting surface
of an LED. Phosphors are designed to absorb a specific type of
light (UV for discharge lamps, or blue light for LEDs) and re-emit
it as a longer wavelength with the purpose of providing visible
light or altering the characteristics of a visible light.
Photometry: The science of measuring visible light in units that
are weighted according to the sensitivity of the human eye to
certain wavelengths of light.
Photopic Vision: Refers to vision involving the cones of the eye;
used in reference to the adaptation of the eye to illuminance of
more than 3.4 candelas per square meter.
Pigtail: An adaptation to a fluorescent ballast that connects
multiple wires together into one convenient socket. Most often
used for Circline lamps.
POMB: See Position Oriented Mogul Base.
Position Oriented Mogul Base: Mogul base lamp that has two
pins near the base of the threads. These pins follow a groove
in a Position Oriented Mogul Base Socket that ensures that a
horizontal-operation lamp is used in the correct position within
a fixture. This base type is also referred to as a POMB.
Potting: A compound, typically made of asphalt and silica, that
is used to fill the inside of a ballast.
Power Factor: A measurement indicating how efficiently
a lighting system is using the power it is drawing. The ratio
between power used (watts) and power being drawn from the
line (volts-amperes). Expressed as a percent or a range from
0 to 1.0. The higher the percent the more efficiently the power
is being used. High power factors are ratings of 0.9 (90%) or
higher. Incandescent lamps are close to 1.0, magnetic ballasts
can be as low as 0.5.
Power Factor Corrected: Ballasts that incorporate a means
of Power Factor Correction but whose power factor is <90%
and >50%.
Preheat Start: A fluorescent lamp-ballast circuit where the
electrodes are heated or warmed by an auxiliary switch or
starter before the lamps light up.
Probe Start: A starting method for HID lamps that involves
the use of a probe to start the lamp. A large surge of voltage
is applied to the probe in order to assist in starting the lamp.
TOC 261

APPENDIX
Glossary of Terms
Programmed Rapid Start: See Programmed Start.

Refraction: The bending of light rays.

Programmed Start: A fluorescent lamp-ballast circuit that uses
a custom integrated circuit (IC), which monitors lamp and ballast
conditions to ensure optimal system lighting performance. PS
ballasts heat the lamp cathodes to 700°C prior to lamp ignition.
This puts the least amount of stress on the lamp electrodes,
resulting in maximum lamp life regardless of the number of lamp
starts. Programmed-start ballasts are typically wired in series.

Refractor: A translucent fixture covering, such as a lens or
diffuser that refracts or bends light rays.

ProLED: Halco’s high performance, energy efficient LED line,
which features lamps designed to provide long life, precise
beam control, solid state construction and tightly controlled
color temperatures.

RGB – also Colormixing: Red, green and blue colors can be
added and mixed to generate a wide range of colors. RGB
control schemes typically employ pulse width modulation to dim
one or more of the primary colors to generate the desired effect.

Pulse Start: A fluorescent lamp-ballast circuit that is designed
with an ignitor to ignite the arc tube. Due to this, bulbs have no
need for the starter electrode. Pulse start lamps are typically
more efficient than standard counterparts.

Scotopic/Photopic (S/P) Ratio: This measurement is a
reference to account for the fact that of the two light sensors
in the retina, rods are more sensitive to blue light (scotopic
vision) and cones to yellow-green light (photopic vision). S/P is
calculated as the ratio of scotopic lumens to photopic lumens
for the light source on an ANSI reference ballast (if applicable).
Higher-color temperature lamps tend to have higher values of
the S/P Ratio compared to lower CCT sources. It is important to
note that many situations will not fall purely into either photopic
or scotopic vision.

Quartz: The commonly used name for fused silica which is
used to make high strength and high temperature tubes and
lamps in the lighting industry. Commonly used in Halogen
capsules, Metal Halide arc tubes, mercury vapor arc tubes
and the protective shroud in open-rated metal halide lamps.
Quartz-Halogen Lamp: See Halogen Lamp.
Radiation: A general term for energy released as a wave or ray.
Includes all forms of visible light, UV, IR, radio, heat waves, etc.
Radiometry: The science of measuring radiant energy, especially
radiant energy in that portion of the total electromagnetic
spectrum lying adjacent to the visible region.
Rapid Start: A fluorescent lamp-ballast circuit which utilizes
continuous cathode heating, while the system is energized, to
start and maintain lamp light output at efficient levels. Rapid
start ballasts may be either electromagnetic, electronic or of
hybrid designs. Full-range fluorescent lamp dimming is only
possible with rapid start systems.
Rated Lamp Life: See Average Rated Life.
Reactor: The most basic circuit type for an HID ballast, made
of a single coil, which acts as an inductor.
Reference Ballast: Laboratory device used to provide ANSIspecified measurements of initial and mean lamp lumens.
Reflector Lamp: An incandescent, halogen compact
fluorescent or HID lamp with a built-in reflecting surface.
Incandescent and HID versions are made from a single piece
of blow-molded soft or hard glass.
Reflector Optic: A reflective secondary optic that is used to
convert wide-emitted light into a different shape and light ray
distribution pattern.
262

TOC

Resistance: A measure of resistance to flow of electrical
current, expressed in ohms.
RFI: See EMI/RFI.

Scotopic Vision: Sight involving the eye’s rods, which respond
to low levels of lighting, below .034 candelas per square meter.
Secondary Optic: A glass, metal or plastic element used in
LEDs and luminaires to change the direction and control the
distribution of light rays.
Self-Ballasted Lamps: See Integrated Lamp.
Series: A type of circuit in which the current flows through
the lamps in sequence. The failure of one lamp results in the
stoppage of current flow.
Shimmer: Changes to the intensity of a lamp that are not visible
from looking directly at the lamp or lit area, but are noticeable
in the peripheral vision.
Shroud: A glass cylinder surrounding the arc tube in metal
halide lamps to protect against the hot arc tube from breaking
the glass bulb if an arc tube rupture occurs. It reduces the risk
of using metal halide lamps in open fixtures.
Single-Ended Lamp: Lamps that have one base or point of
electrical connection.
SI: International System of Units. Most widely used standards
for measurement.
Slim Case: A reduced size case for fluorescent ballasts to allow
for more versatile applications.
SMD: See Surface Mount Diode.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com

APPENDIX
Glossary of Terms
Soft White (fluorescent): A term to describe a fluorescent
lamp that has a low correlated color temperature, typically
around 3000K.
Soft White (incandescent): A lamp with a silica coating on the
inside of the bulb to provide very diffuse light and completely
conceal the filament.
Solid State Lighting: Lighting based on the use of
semiconductors, see Light Emitting Diode.
Sound Rating: A rating of the amount of sound produced in
the normal operation of a ballast. “A” is the normal favorable
rating, producing the lowest amount of sound, while “E” is
the least favorable rating, producing the greatest amount of
audible noise.
SOX: Low Pressure Sodium abbreviation term.
Spectral Power Distribution: Distribution of spectral emissions
from a lamp, in either relative terms or absolute terms, used
to determine CCT and chromaticity of a light source. Often
accompanied by a visual representation of the radiant energy
emitted by a light source as a function of wavelength. SPDs
provide a visual profile or “fingerprint” of the color characteristics
of the source throughout the visible part of the spectrum. Also
called “spectral curve” or “spectrum”.
Spiral Lamp: A helical-shaped long life compact fluorescent
lamp.
Spotlight: A lamp designed to produce a narrow beam angle
to illuminate a specifically defined area.
SSL: See Solid State Lighting.
Starter (Ignitor): A device used in conjunction with a ballast to
start preheat fluorescent lamps.
Striation: Describes a condition in a fluorescent lamp where
a series of bright and dim areas are exhibited, and sometimes
move down the length of the lamp. These are common in
reduced wattage lamps, which use heavy fill gasses such as
Krypton. It is not an indication of a ballast or lamp problem and
will not impact the lamp or ballast, and are most often seen
during lamp warm-up or when the temperature on the outside
wall of the lamp is too low.
Super CWA: Constant wattage, Auto-Transformer for use with
Pulse Start Metal Halide Lamps.
SureColor: Prism MR16 lamps that feature a UV-stop quartz
capsule, titanium coated dichroic reflector for consistent color,
and an axial filament for precise beam control.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

Surface Mount Diode: A type of LED package for mounting
to the surface of a circuit board. This format allows for better
thermal dissipation for the diodes and helps maintain the long
life of LEDs. See LED Package.
Task Lighting: Lighting directed to a specific surface or area
that provides illumination for specific tasks.
TCLP Test: The Toxicity Characteristic Leaching Procedure
(TCLP) test, specified in the Resource Conservation and
Recovery Act (RCRA) of 1990, is used to characterize
fluorescent lamp waste as hazardous or non-hazardous waste.
The TCLP test measures the ability of the mercury in a lamp to
leach from a landfill into ground water under very aggressive
and reactive conditions.
Thermal Protector: A device used in a ballast to detect when
the maximum temperature of the ballast has been exceeded
and when to remove input power. Thermally protected ballasts
that meet UL certifications are classified as “Class P.”
Total Internal Reflection Optic: A glass or transparent
plastic secondary optic that uses the principle of Total Internal
Reflection (TIR) to efficiently direct the light rays of an LED from
the wide emitting pattern into a different beam distribution. Most
commonly composed of PMMA plastic.
Total Harmonic Distortion (THD): A measure of the distortion
of an electrical wave form. Excessive THD may cause adverse
effects to the electrical system.
Transient Protection: See TVSS.
Transients: High voltage surge through an electrical system
that can lead to premature ballast or integrated lamp failure.
A transient may be caused by lightning strikes to nearby
transformers, lines or ground, or by switching of motors or
compressors (via inductive kick), as well as by circuit shorts.
Tri-Phosphor: Term used to describe fluorescent lamps,
including most compact fluorescent lamps, which use a
combination of at three phosphors (red, green and blue) to
generate white light efficiently and with good color rendering.
Trigger Start: A circuit that eliminates the starter and allows
for instant starting of preheat lamps.
Troffer: A long recessed lighting fixture, usually installed flush
with the ceiling.
Tungsten Halogen Lamp: See Halogen Lamp.
TVSS: Transient Voltage Surge Suppressors. These are devices
that are installed to protect ballasts and other electronic
equipment from transients that may occur in the power line.

TOC 263

APPENDIX
Glossary of Terms
Two-Pin Compact Fluorescent Lamps: Type of lamps that
have a starter integrated into the base of the lamp. Traditionally
2-pin lamps are designed to work with magnetic ballasts.
UL: Underwriters Laboratories. Laboratory that sets safety
standards for building materials, electrical appliances and
other products.
Ultraviolet: Radiant energy in the wavelength range of about
100 to 380 nanometers (nm). This light is invisible to the naked
eye and is also known as black light. Applications include:
Blacklight 320-400 nm
Germicidal 220-300 nm
Ozone-producing 180-220 nm

Warm White: Refers to a low color temperature of light,
nominally refers to light with a correlated color temperature of
3000K or 2700K, resulting in a yellow-white light. Typically refers
to discharge or LED products, as halogen and incandescent
light tend to fall in this category naturally.
Watt: A unit of electrical power. One watt is equal to one ampere
of current flowing through one ohm of resistance.
Wavelength: Distance between two successive points of
a periodic wave; the wavelengths of light are expressed in
nanometers (nm).

Very High Output (VHO) Lamps: Fluorescent lamps designed
to be used with a 1500 milliampere ballast.
Visible Spectrum: Radiant energy in the wavelength range of
about 380 to 770 nanometers (nm). The light that can be seen
by the human eye and produces what we also call the “color
spectrum.”
Volt: The unit of electromotive force (emf). The difference in
electrical potential that will cause a current of one ampere to
flow through a resistance of one ohm.
Voltage Rating: The recommended operating voltage for a
lamp.
Voltage Sag: Drop in voltage levels of electrical distribution
system or electrical circuit that interferes with the operation
of electrical and electronic equipment. Commonly called a
“Brownout”. Results when demand for electricity exceeds
capacity of the distribution system, and is more common in
some areas of the country.
Voltage Surge: See Transient.
Warm-Up Time: The time it takes a lamp to get to full
brightness. Incandescent, Halogen and LED lamps have
effectively no warm up time. Discharge lamps do not come on
at full brightness upon startup and:
· Most fluorescent lamps come on at 80% or greater
brightness and warm up the rest of the way very
quickly.
· Covered compact fluorescent and amalgam
fluorescent lamps start at a lower brightness and can
take up to 3 minutes to reach full brightness.
· HID lamps take 3-10 minutes to warm up to full
brightness after starting and typically start at a very
low proportion of brightness.

264

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

APPENDIX
Lamp Warranty

HALCO LIGHTING TECHNOLOGIES LAMP LIMITED WARRANTY
Halco Lighting Technologies (hereinafter called “Halco”), 2940 Pacific Drive, Norcross, GA 30071, warrants to the
purchaser that Halco lamps will be free from defect in the material and workmanship from the date of manufacture for
the following time periods:
Lamp Category

Warranty

Self-Ballasted CFL 42 watts or less:

2 years

Self-Ballasted CFL greater than 42 watts:

1 years

Plug-in Compact Fluorescent:

1 years

High Power LED:

5 years

IP65 Rated JC LED (40,000 hour rated life):

5 years

Standard JC LED (20,000 hour rated life), C7 and C9 LED:

2 years

Linear Fluorescent, non-pre-heat > 14 watts:

2 years

ProLume Linear Fluorescent, non-pre-heat > 14 watts
operated on a ProLume Ballast:

3 years

All other lamps are covered under our Quality Assurance noted below.
Explicit Operating Conditions:
Self-Ballasted and Plug-In Compact Fluorescent Lamps: Based on maximum of 10 hours use per day.
Should any product fail to meet the warranty specified above, Halco, at its option, shall correct any defect by issuing a credit for the product or providing a free
replacement lamp. This warranty is conditioned upon proper storage, installation, use and maintenance. Remedy is expressly limited to credit or replacement only.
This warranty is not applicable to any lamp, which is not installed and operated in accordance with the current edition of the National Electric Code (NEC), the
Standards for Safety of Underwriters Laboratory, Inc. (UL), the Standards for the American National Standards Institute (ANSI), and with Halco instructions and
guidelines for the lamp. This warranty is not applicable to any lamp subjected to abnormal stresses and operating conditions. Use of occupancy sensors, dimmers
or programmable systems with some lamp types may void the warranty.
Halco reserves the right to examine all lamps prior to the determination of warranty status. All lamps must be retained for warranty claims. The warranty period
starts on the date of installation. If the date of installation cannot be determined or is unknown, the warranty period will start with the date of the original purchase
from Halco.
Warranty Exclusion Clause for Products Exported:
This warranty shall be void for products that are exported outside of the U.S. and its territories. The distributor, private labeler or OEM assumes all responsibility
imposed by statue, regulation or law on products sold into these markets.
NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY BEYOND
THE AFOREMENTIONED WARRANTY PERIOD.
The foregoing warranty is exclusive of all other statutory, written or oral warranties, and no other warranties of any kind, statutory or otherwise, are given or herein
expressed. The warranty sets forth Halco’s responsibilities regarding the ballast and claimant’s exclusive remedy.
Warranty claims are to be made in accordance with Halco’s published Warranty Program, made available upon request.
LIMITATION OF LIABILITY. Halco will not under any circumstances, whether as a result of breach of contract, breach of warranty, tort, strict liability or otherwise,
be liable for consequential, incidental, special or exemplary damages including, but not limited to, loss of profits or revenues, loss of use of lamp or any other goods
or associated equipment or damage to any associated equipment, cost of capital, cost of substitute products, facilities of service, down time cost, or claims of
claimant’s customers. Halco’s liability on any claim of any kind for any loss of damages arising out of, resulting from or concerning any aspect of this agreement
from the products or services furnished hereunder shall not exceed the price of the specific lamp or lamps which gives rise to the claim.
Some states do not allow the exclusion of limitation of damages or the length of time for an implied warranty. Therefore, the limitations or exclusions of consequential or incidental damages and implied warranties may not apply to certain claimants. This warranty gives the claimant specific legal rights. The claimant may also
have other rights, which vary from state to state.
Quality Assurance Guarantee
At Halco Lighting Technologies, we are committed to quality and service. We measure our success by one standard, customer satisfaction. With this in mind, we
offer you the following: Should you encounter any product from Halco Lighting Technologies that fails to perform according to specifications, contact your account
representative immediately. If our product is found to be defective in either material or workmanship, we will credit your account or replace the product at no
charge. In order to better maintain our standard of quality, we reserve the right to inspect any defective products. We make this assurance to clearly demonstrate
our commitment to your satisfaction.

Halco Lighting Technologies | 800.677.3334 | halcolighting.com

TOC 265

APPENDIX
Ballast Warranty

HALCO LIGHTING TECHNOLOGIES LAMP BALLAST LIMITED WARRANTY
Halco Lighting Technologies (hereinafter called “Halco”), 2940 Pacific Drive, Norcross, GA 30071, warrants to the
purchaser that its ballasts will be free from defect in the material and workmanship from the date of manufacture for the
following time periods:
Ballast Category

Warranty

Electronic Fluorescent:

5 years

ProFormance Electronic Fluorescent:

5 years

ProFormance Electronic Compact Fluorescent:

5 years

Electronic Residential:

5 years

Electromagnetic Compact Fluorescent:

3 years

Electronic Sign:

3 years

Electronic HID:

3 years

Core & Coil HID:

2 years

Should any product not meet the warranty specified above, Halco, at its option, shall correct any defect, by either repairing any defective part of
parts or by replacing any defective part or parts or by making available a new replacement ballast. This warranty is conditioned upon proper
storage, installation, use and maintenance.
This warranty is not applicable to any ballast, which is not installed and operated in accordance with the current edition of the National Electric
Code (NEC), the Standards for Safety of Underwriters Laboratory, Inc. (UL), the Standards for the American National Standards Institute (ANSI),
and with Halco instructions and guidelines for the ballast. This warranty is not applicable to any ballast subjected to abnormal stresses and
operating conditions.
The conditions of any tests [to be] performed on Ballast Products, which are claimed to have not performed in accordance with the terms of this
warranty, shall be mutually agreed upon in writing and Halco shall be notified of, and may be represented at such tests. Halco extends this express
limited warranty to the original purchaser.
NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY BEYOND
THE AFOREMENTIONED WARRANTY PERIOD.
The foregoing warranty is exclusive of all other statutory, written or oral warranties, and no other warranties of any kind, statutory or otherwise, are
given or herein expressed. The warranty sets forth Halco’s responsibilities regarding the ballast and claimant’s exclusive remedy.
Warranty claims are to be made in accordance with Halco’s published Warranty Program, made available upon request.
LIMITATION OF LIABILITY. Halco will not under any circumstances, whether as a result of breach of contract, breach of warranty, tort, strict
liability or otherwise, be liable for consequential, incidental, special or exemplary damagees including, but not limited to, loss of profits or revenues,
loss of use of ballast or any other goods or associated equipment or damage to any associated equipment, cost of capital, cost of substitute
products, facilities of service, down time cost, or claims of claimant’s customers. Halco’s liabitlity on any claim of any kind for any loss of damages
arising out of, resulting from or concerning any aspect of this agreement from the products or services furnished hereunder shall not exceed the
price of the specific ballast or ballasts which gives rise to the claim. Per the Halco Warranty Service Program, Halco will provide a maximum labor
allowance of ten dollars ($10.00) per ballast for Electronic Ballasts only.
Some states do not allow the exclusion of limitation of damages or the length of time for an implied warranty. Therefore, the limitations or exclusions
of consequential or incidental damages and implied warranties may not apply to certain claimants. This warranty gives the claimant specific legal
rights. The claimant may also have other rights, which vary from state to state.
Warranty Exclusion Clause for Products Exported:
This warranty shall be void for products that are exported outside of the U.S. and its territories. The distributor, private labeler or OEM assumes all
responsibility imposed by statue, regulation or law on products sold into these markets.

266

TOC

Halco Lighting Technologies | 800.677.3334 | halcolighting.com



Navigation menu