LAMP & BALLAST CATALOG
Halco Lighting Technologies is a leader of lamp and ballast solutions
for commercial, industrial, residential and specialty lighting applications.
Established in 1974, Halco is headquartered in Atlanta with distribution
centers in Carlstadt, Cleveland, Houston, Los Angeles and Phoenix.
43
77 LINEAR FLUORESCENT LAMPS
COMPACT FLUORESCENT
LAMPS
LED LAMPS
93 HID LAMPS
117 HALOGEN LAMPS
CONTENTS
57
155 SPECIALTY LAMPS
135 INCANDESCENT LAMPS
171 ELECTRONIC FLUORESCENT
BALLASTS
207 ELECTRONIC SIGN BALLASTS
250 APPENDIX
ELECTROMAGNETIC HID
BALLASTS
233
213 COMPACT FLUORESCENT
BALLASTS
227 ELECTRONIC HID BALLASTS
This catalog has been hyperlinked for your convenience.
Click on an image to navigate to each section.
Halco Lighting Laboratories, located at our Atlanta
headquarters, is our state of the art NVLAP-
accredited facility utilized for quality control and
product development.
Halco Lighting Technologies offers one of the most comprehensive product lines in the industry, including
the proprietary brands ProLED®, ProLume®, HaloXen®, Prism® and CoverShield®. Our manufacturing
expertise is put to the test in our state-of-the-art, in-house NVLAP-accredited laboratory.
In addition to superior quality products, Halco contributes to the vibrant and responsible lighting industry
through association membership and knowledge sharing. Together, we focus on key industry issues
including legislation, environmental impact, energy-efciency and process standards.
Halco focuses on being easy to do business with; illustrated by our knowledgeable and empowered
customer service representatives and online support tools. As your partner, Halco strives to be your only
choice for lamp and ballast products.
LED Product Partner
Knowledgeable, empowered customer service representatives serve as your dedicated in-house
contact. Our representatives receive continuous product and industry training. They are your resource
for product availability, pricing, order fulllment and technical support.
In addition to our personalized service, Halco’s offers 24/7 electronic support at halcolighting.com, which
is operated by our advanced enterprise software. Halco’s full-feature e-commerce website provides
access to in stock availability, order entry, delivery status and order history for our distributor partners.
You can also locate product information quickly with our online product search or category drill down.
For a comprehensive directory of product literature, compatibility and application information as well as
white papers, visit our online literature library.
Halco’s strategically located, fully stocked regional warehouses provide you maximum service with
minimum transportation time and costs. Halco’s deep inventory levels of lamp and ballast SKUs increases
your ability to service your customers. Every Halco distribution center adheres to our aggressive service
policy to ship orders received by 2:00PM local warehouse time the same day. Will-call service is also
available for your convenience. With distribution centers in Atlanta, Carlstadt, Cleveland, Houston, Los
Angeles and Phoenix, we are able to deliver to over 85% of United States same day or next day.
SERVICE
QUALITY
As part of our commitment to quality and innovation, we operate our own state-of-the-art NVLAP-
accredited testing laboratory at our headquarters in Atlanta. Based on a quality management system
outlined in ISO 17025, Halco Lighting Laboratories features a goniophotometer for photometric testing
as well as a temperature-controlled integrating sphere that tests environmentally sensitive products.
We conduct a number of tests according to IESNA standards, including photometric distribution, light
output, color and electrical properties. The Halco Lighting Laboratories product testing facility ensures
continuous quality control and outstanding product performance.
At Halco Lighting Technologies, we are committed to quality and service. We measure our success
by one standard, customer satisfaction. With this in mind, we offer you the following:
Should you encounter any product from Halco Lighting Technologies that fails to perform
according to specifications, contact your account representative immediately. If our
product is found to be defective in either material or workmanship, we will credit your
account or replace the product at no charge. In order to better maintain our standard of
quality, we reserve the right to inspect any defective product.
We make this assurance to clearly demonstrate our commitment to your satisfaction.
Lumens: 260 Beam Spread: 32°
PAR36/6WW/WFL/LED2
Coverage
20'
18'
16'
14'
12'
10'
8'
6'
4'
2'
2.20
2.72
3.44
4.49
6.12
8.81
13.76
24.46
55.00
220.10
FC
0' 2' 4' 6' 8 ' 10' 12'
Throughout the years we’ve continued to invest in our partnership by growing our product offering,
leveraging global manufacturing resources and developing a knowledgeable service team. As we look
to the future, Halco remains committed to providing you innovative lamp and ballast products with
unparalleled service.
When you think lamps and ballasts, think Halco.
PRODUCT
Solid State Lighting Compact Fluorescent,
Linear Fluorescent & HID
Lamps and Ballasts
High Performance,
Extended Life and Energy
Saving Halogen-Xenon
Halogen and Value Added
Incandescents
Safety Coated Lamps
Incandescent and Photo/
Projection Lamps
®
LED LAMPS
Halco has one of the most comprehensive LED lamp offerings available in the industry, boasting impressive
savings of up-to 88% in energy costs. Our award-winning LED product line features an unrivaled combination
of efciency, long life and light output, providing the best overall performance in LED technology. ProLED®
products utilize the highest quality components, including USA and Japanese chips, precision manufactured
optics, optimally engineered drivers and special heat sinks for superior thermal management.
High Power LED Lamps
All high power ProLED® products are specied at 40,000 hours rated life to L70, meaning the lamp will provide
70% of its initial specied lumens at rated life. Backed by a 5-year warranty, these lamps provide consistent
lamp-to-lamp color, precise beam control and reduced maintenance. Our MR, Reector and PAR lamps are
available in multiple beam spreads, wattages and colors.
JC Type Lamps
Halco’s ProLED® JC lamps are rated up-to 40,000 hours and backed by a 5-year warranty on IP65 Rated and
2-years on standard JC lamps. Available with bi-pin and bayonet base types, these lamps offer reduced
maintenance and do not project heat. ProLED® JC Lamps are available with bi-pin and bayonet base types, in
3000K and multiple colors, 10-18V input voltage range and IP65 rated options for outdoor use.
Energy Efcient Alternatives
Halco’s ProLED® offering features a wide variety of energy efcient alternatives to traditional lamp types. Ideal
for replacement and retrot, ProLED® lamps include the award-winning Elevator lamps, Chandelier lamps with
cream, chrome and brass base options, Decorative B10 and CA10 lamps, clear and color Sign lamps, colorful
C7 & C9 lamps, Decorative Globe and Linear T8 lamps.
Environmentally Responsible
Halco’s offering of ProLED® lamps contain no mercury or lead (RoHS compliant) and emit no ultraviolet and
infrared radiation.
ENERGY STAR® Rating
Halco’s ENERGY STAR products deliver exceptional features while generating savings for
consumers. For our most current ENERGY STAR products, please visit our literature library at
www.halcolighting.com/download.
COMPACT FLUORESCENT LAMPS
Compact Fluorescent lamps are specied for a growing number of applications, especially where the objectives
are energy savings and reduced maintenance costs. In fact, they save up-to 80% in energy costs and last up-to
ten times longer than standard Incandescent lamps. ProLume® has become a popular choice due to our wide
range of high performing, reliable products.
ENERGY STAR® Rating
Halco’s ENERGY STAR products deliver exceptional features while generating savings for consumers.
For our most current ENERGY STAR products, please visit our literature library at www.halcolighting.
com/download.
Eco-Shield®
The Eco-Shield mark indicates TCLP compliant
lamps, a smart choice for environmental responsibility.
Plug-In Lamps
Halco’s TCLP compliant lamps ensure energy
efciency and light levels. These lamps are available in
2700K, 3000K, 3500K, 4100K and 5000K. Common
applications include wallwash units, ood lighting,
low bays and desk lamps. Our lamps offer up-to
20,000 hours average rated life and are available in
5 to 57 watts.
High-Lumen Long
Flicker-free performance, increased optical control
and up-to 85 lumens per watt make these lamps an
economical alternative to T8 and T12 U-Bend lamps.
Offering up-to 20,000 hours average rated life, our
high-lumen lamps are TCLP compliant and are backed
by a 1-year warranty.
Self-Ballasted CFLs
Instant-start electronic ballast technology gives these
lamps reliable starts even in cold applications. Available
in a wide variety of lamp types including dimmable,
reectors, decorative and bare spirals to meet almost
any need.
LINEAR FLUORESCENT LAMPS
Eco-Shield®
The Eco-Shield mark indicates TCLP compliant lamps,
a smart choice for environmental responsibility.
CEE
Halco is proud to offer one of the largest listings of
CEE lamps in the industry, dening efciency and
high-performance lighting products and encouraging
the use of energy-efcient products.
Participating utilities across the U.S. commonly
offer signicant rebates to commercial and industrial
customers that utilize CEE qualied high performance
and reduced wattage ballasts and lamps in new
construction, replacement and retrot projects. For
an up-to-date list of our CEE listed items, please visit
www.halcolighting.com/download.
Lamp and Ballast Systems
Imagine increasing lumens per watt performance
while reducing total power consumption.
ProLume reduced wattage T8 lamps are perfect in
applications that require near equivalent or slightly
less light than standard 32W T8 lamps. ProLume
lamps feature a performance-enhancing tri-phosphor
coating that improves both the light quality (CRI) and
efciency of the lamps.
System Warranty
Halco’s Linear Fluorescent lamps are engineered to
provide optimum performance when operated by a
ProLume ballast. In fact, Halco extends the warranty
of its Linear Fluorescent lamps when installed with a
new ProLume ballast for a maximum of three years
from date of original installation. See warranty for
details at www.halcolighting.com/download.
Advancing technologies and environmental focus have changed the face of Linear Fluorescent lighting. From
ultra thin and efcient to specialized applications, Halco has your lighting needs covered with an assortment of
reliable ProLume® Linear Fluorescent lamps and ballasts.
LINEAR FLUORESCENT LAMPS
LINEAR FLUORESCENT LAMPS
HID LAMPS
Utilizing the latest technologies, Halco offers a broad selection of Metal Halide, High Pressure Sodium
and Mercury Vapor lamps that cover a wide range of common and specialty applications.
Ceramic Discharge Metal Halide
Halco’s Ceramic Discharge Metal Halide (CDM)
lamps offer an array of benets including excellent
color rendering, energy efciency and long life. They
offer up-to 16,000 hours average rated life and
feature a single piece arc tube design for a more
dened white light.
Pulse Start Metal Halide
Pulse Start lamps provide a quick re-strike, up-
to 110 lumens per watt and 20% higher lumen
maintenance than standard Metal Halide lamps.
ProLume Pulse Start lamps are available in 50 to
1000 watts.
Protected Metal Halide
Designed for operation in open xtures, these
shrouded MP lamps are available in both Pulse
Start and Standard Metal Halide. The protective
quartz shroud surrounds the arc tube, providing
both safety and UV ltering.
Specialty Metal Halide
ProLume aquarium, color and safety coated Metal
Halide lamps are available in a variety of lamp types
to t your special application needs.
High Pressure Sodium
ProLume offers a complete line of High Pressure
Sodium (HPS) lamps for general lighting applications.
These lamps are extremely energy efcient and are
a good choice for lighting large areas where color
rendering is not crucial and long life is desired.
Mercury Vapor
Mercury Vapor lamps produce an efcient white
light and are a cost effective light source for general
and security lighting. Prolume Mercury Vapor lamps
range from 50 to 1000 watts and are available in
traditional HID lamp shapes as well as A23 and R40
shapes.
HALOGEN LAMPS
Replacements for Legislated Halogen PAR Lamps
Halco has developed three unique options for replacing 45 to 120 watt Halogen PAR lamps affected by DOE energy
conservation standards. Our three solutions address various marketplace performance and value considerations
so you can match each customer with the right lamp:
Halco offers a broad selection of Halogen lamp types, wattages and bases to meet lighting needs for general,
display/accent, and retail applications. HaloXen® lamp technology utilizes a mix of Halogen and Xenon gas that
improves efciency and lamp life over standard Halogen lamps. HaloXen® lamps provide integrated UV protection,
elevated color temperature and a crisp, white light throughout the life of the lamp.
HALOGEN LAMPS
1HaloXen® PAR Reector Series
An economic and energy efcient
alternative to legislated PAR20,
PAR30, PAR30L and PAR38
Halogen lamps. HaloXen® PAR
Reector 130V options are available
for customers with voltage spike
concerns.
2 HaloXen Silver PAR Series
Pair a Xenon burner with a silver
reector to improve efcacy by up-
to 30% over standard Halogen.
PAR30, PAR30L and PAR38 Silver
PAR lamps that offer up to 19.75
lumens per watt.
3 XIR Infrared PAR Series
Utilize an infrared capsule to
achieve up-to 30% higher lumens
per watt than standard Halogen
lamps and have an average rated
life of 3,500 hours. XIR Infrared
PAR lamps replace standard 75W
PAR30, PAR30L and PAR38 lamps.
Replacements for Legislated Incandescent A19 Lamps
PRISM® Halogen A19 lamps are the ideal replacements for Incandescent A19 lamps affected by the standards
enacted by the Energy Independence and Security Act (EISA). These lamps deliver the same light quality as
Incandescent lamps while using 28% less power. Clear and soft white Incandescent replacements are available.
INCANDESCENT LAMPS
®
Our General Service and Decorative Incandescent lamp offering is one of the most comprehensive product
assortments available from a single source. Halco’s extensive global manufacturing capabilities ensure both
selection and quality in our Incandescent lamp family.
Halco® and PRISM® brands each represent specic product segments targeted to t various needs from industrial,
commercial, or residential markets. Residential products are identied with the Halco brand and are packaged
for retail presentation. PRISM® branded products signify long life, value-added lamps for industrial/commercial
applications. With so many options, there is a Halco lamp for every need.
PRISM® Long Life Plus
Constructed using a heavy-duty staggered support C-9M lament, these 5,000 hour 130 Volt lamps provide long
life and are suitable for rough service applications. Halco offers a large assortment of lamp types and wattages
sure to meet all industrial/commercial applications.
PRISM® Ultralife
Designed using the same heavy-duty lament as our Long Life Plus lamps, these industrial/commercial
lamps utilize a krypton gas ll to maximize lamp life up-to 20,000 hours. Ideal for hard-to-reach or high ceiling
applications, UltraLife lamps are available in a variety of wattages and lamp types.
SPECIALTY LAMPS
Photo/Projection/SSTV
Halco offers an array of ANSI-coded Photo, Projection and SSTV lamps that are precision built to maximize light
quality, control and stability in order to meet the needs of various specialty applications.
Miniatures
Miniature lamps are designed for applications which include aircraft, auto, marine, railway indicator and truck, as
well as emergency, garden, indicator, instrument, microscope, radio and telephone indicator products.
Sealed Beam
These ANSI-coded PAR lamps are available in a number of wattages that feature beam spreads and sizes to meet
an assortment of lighting needs. Halco sealed beam lamps are manufactured to the highest quality standards and
comply with strict ANSI specications.
Halco offers a wide variety of Specialty lamp types and lamp accessories to meet diverse application needs,
including Photo/Projection/SSTV lamps, Miniature lamps, Safety Coated lamps, Sealed Beam lamps, Socket
Adapters and Tube Guards.
®
COVERSHIELD LAMPS
Shatter Resistant Lighting
CoverShield®, Halco’s safety coated product line, features a comprehensive offering of shatter-resistant
lamps and coatings designed to meet a variety of application requirements. Types of coatings vary
depending on the lamp application. In high heat environments, for example, PFA is used while other
industry leading materials are applied elsewhere. The CoverShield product line includes Compact
Fluorescent, Linear Fluorescent, Incandescent, Halogen and Metal Halide lamp categories.
COVERSHIELD LAMPS
Halco’s ProLume® Electronic Fluorescent ballasts are designed with energy efciency, reliability, ease-of-use and reduced
maintenance costs in mind.
ProFormance® Ballasts
Halco’s exclusive ProLume ProFormance Electronic ballasts, identiable by the “EP” product code prex, feature high power
factor, less than 10% THD, and are available in both multi-volt and dedicated voltage models. ProLume ProFormance ballasts
are renowned for their guaranteed versatility, efciency and minimal power loss.
Multi-Volt
Operating on a universal input voltage between 108 and 305 volts, ProLume ProFormance Multi-Volt ballasts utilize a single
power lead that doesn’t require special wiring. This feature simplies ordering, reduces inventory costs and provides peace-of-
mind that one ballast can be used in multiple applications.
Electronic Upgrades from Magnetic T12 Ballasts
Halco offers a number of electronic solutions for replacing magnetic T12 ballasts. ProLume Electronic ballasts provide more
than 20% energy savings compared to their magnetic counterparts. Furthermore, ProLume Electronic ballasts are quieter,
provide icker-free operation and are easier to handle due to their reduced weight and size. Backed by a 5-year warranty,
ProLume Electronic Fluorescent ballasts are an efcient, convenient and long-life upgrade from traditional ballasts.
ProLume® High Efciency T8 Ballasts
All Halco ProLume High Efciency ballasts are NEMA Premium designated and CEE qualied high performance or reduced
wattage ballasts, signifying that they meet or exceed the stringent performance requirements set by NEMA and CEE. ProLume
High Efciency ballasts are eligible for many utility rebates that often cover a signicant portion of the product’s upfront costs.
Certication
All ProLume Electronic ballasts are certied by Underwriters Laboratories for use in the United States and are certied by either
Underwriters Laboratories or Canadian Standards Association (CSA) for use in Canada and backed by a 5-year warranty.
ELECTRONIC FLUORESCENT BALLASTS
ELECTRONIC FLUORESCENT BALLASTS
APP SHOT
Halco’s ProLume® Electronic Sign ballasts are energy efcient, user-friendly alternatives to magnetic sign ballasts.
Energy Efcient
ProLume Electronic Sign ballasts consume up-to 25% less energy than magnetic sign ballasts. Savings are quickly realized,
particularly in applications where signs are operated for an extended period of time.
Versatile Replacement For Magnetic Sign Ballasts
Operating cooler and quieter than magnetic sign ballasts, ProLume Electronic Sign ballasts cover all signage applications
that require one to six T8/HO and T12/HO lamps that have a total length between 2 and 48 feet. They are much lighter and
have fewer wires than their magnetic counterparts, easing installation and maintenance. With their multi-volt capability (120-
277V), ProLume Electronic Sign ballasts address more applications with fewer SKUs than standard magnetic sign ballast
lines, reducing distributors’ inventory costs.
Parallel Lamp Operation
The parallel lamp operation ensures that if a lamp fails, the remaining lamps will continue operating, keeping the sign lit.
These instant start ballasts provide reliable starting in temperatures as low as -20°F.
Certications
ProLume’s electronic sign ballasts are UL listed and backed by a 3-year warranty.
ELECTRONIC SIGN BALLASTS
Halco’s ProLume® Compact Fluorescent (CFL) ballasts offer a broad assortment of options for lighting applications that require
4-pin Compact Fluorescent lamps. Look for the ProFormance (EP) mark, which identies ProLume CFL ballasts that feature high
power factor operation and less than 10% THD.
Programmed Start
ProLume ProFormance® CFL ballasts feature programmed start circuitry, which surpasses standard rapid start technology.
Programmed start ballasts precisely heat the lamp lament and tightly control the duration of preheating before applying the
starting voltage to the lamp. The result is improved performance of both the lamp and ballast and extended life of the lamp.
Quick-Connect
Our Quick-Connect technology simplies installation and maintenance of ProLume ProFormance CFL ballasts. Under this color-
coded system, wire installation is easy and the need to cap off unused leads is eliminated. The wire-removal tool included with
the kit allows for quick and easy wire disconnecting.
Distributor Kits
ProLume ProFormance CFL ballasts are ideal for replacement applications due to their multi-volt capability and Dual Connection
feature, which provides side and bottom lead exits utilizing Quick-Connect technology. Distributor Kits include everything that is
necessary for ballast replacement including a mounting plate, lead-wire set, wire-removal tool and mounting hardware.
End-of-Life Protection
ProLume ProFormance CFL ballasts are equipped with end-of-life protection. This technology safely removes power supplied
to the lamp during failure. After a failed lamp has been replaced, the ballast auto-resets and provides power to the new lamp.
Certications
All ProLume Compact Fluorescent ballasts are certied by Underwriters Laboratories for use in the United States and Canada
and backed by a 5-year warranty.
COMPACT FLUORESCENT BALLASTS
Halco’s Electronic HID (eHID) ballasts are designed to meet a variety of application needs for low wattage Metal Halide
lamps. These eHID ballasts are compact and provide distinct advantages over magnetic versions. Key benets of Halco eHID
ballasts include enhanced light quality, increased versatility, greater savings and improved safety.
Superior Light Output
Halco eHID ballasts are microprocessor controlled, which allows for constant monitoring and regulation of wattage delivered
to the lamp. This feature, combined with a virtually icker-free design, results in greater lumen maintenance, precise beam
control and a more uniform light appearance.
Flexible Voltage and Mounting
Our eHID ballasts are compatible with both 120 and 277 voltages and operate metal halide lamp wattages of 20W, 35/39W
and 70W. Each ballast and wattage is available with either side or bottom lead exits and mounts for versatility. In addition,
Halco’s eHID ballasts are lightweight, easy to install and reduce shipping expenses.
Savings
In addition to improved light quality, eHID ballasts provide lamps with higher efcacy and longer life compared to magnetic
ballasts. Increased efcacy through reduced ballast losses allows for less power consumption while maintaining light levels,
resulting in energy savings. Plus, longer lamp life on eHID ballasts decreases costs associated with frequent lamp replacement.
Safety Features
Our eHID ballasts provide protection against no-lamp and end of life operation. Continuous striking without a lamp, or with a
failed lamp present, could damage circuits. Halco’s eHID ballasts prevent these scenarios. Additional protection is provided
through integrated thermal and over-voltage circuits designed to shut down the ballast if operating conditions exceed those
specied for use.
Certications
ProLume eHID Ballasts are backed with a 3-year warranty.
ELECTRONIC HID BALLASTS
ProLume® Core and Coil HID ballasts operate a wide variety of Standard and Pulse Start Metal Halide and High Pressure
Sodium lamp types.
Multi-Tap
ProLume HID ballasts provide a wide range of multi-tap ballast options. 4-Tap ballasts are offered throughout the line, while
5-Tap ballasts are available for higher wattages. Multi-tap engineering means one ballast for applications with 120V, 208V,
240V, 277V and 480V (5-tap models).
Distributor Kits
ProLume HID ballasts come in complete distributor replacement kits. Kits include an Ignitor when applicable, a Capacitor
when required, as well as mounting brackets and hardware.
Capacitors and Ignitors
For your convenience, Capacitors and Ignitors can be purchased individually. ProLume Ignitors are manufactured using only
the highest quality components. Replacement Dry Film and Oil-Filled Capacitors are also available for all ProLume ballasts.
Oil-Filled Capacitors are provided with ballasts 1000 watts and above.
Certications
All ProLume Electromagnetic HID ballasts, Ignitors and included Capacitors are certied by Underwriters Laboratories for
use in the United States and Canada and backed with a 2-year warranty.
HID ELECTROMAGNETIC BALLASTS
®
LED LAMPS
CONTENTS
44
45
45
45
47
48
50
50
51
51
52
52
52
53
54
How to Read a Table
JC Type Lamps
Elevator Lamps
Decorative Lamps
MR11 & MR16 Lamps
PAR Lamps
Linear Lamps
Sign Lamps
Reector Lamps
Pool Bright Lamps
Miniature Lamps
C7 and C9 Lamps
Headlamps
Bulb and Base Identication
Symbols, Footnotes and Abbreviations
main
TOC
BULB
Designations indicate shape and size.
Illustrations can be found on page 53
and at the top of each page.
BASE
Indicates base type.
Full base descriptions and
illustrations can be found
on page 53.
PACKAGE
QUANTITY
Indicates minimum sell
quantity and smallest
shipping carton.
PRODUCT
CODE
Abbreviated product description
can also be used for ordering.
A key to abbreviations can be
found on page 55.
WATTS
Indicates the
power consumed
by the lamp during
operation.
PRODUCT
NUMBER
Use this number when
placing an order.
FOOTNOTES &
SYMBOLS
Related footnotes can
be found on page 54.
LUMENS
Represents
average
light output.
DESCRIPTION
Bulb nish and other
important information.
MOL
Indicates
maximum
overall
length in
inches.
LIFE
Rated at L70.
COLOR
TEMP.
A term used to
describe the
color of a light
source and is
expressed in
degrees
“Kelvin” (K).
BEAM
SPREAD
Indicates the
beam angle or
beam spread
of a bulb,
measured in
degrees.
JC Type Lamps
1.5 WATT
JC10 G4 80693 $ 1,4,5,6 JC10/1WW/LED 10-18 82 3000 120 20000 1/40 - 1.21”
80776 $ 1,4,6,10 JC10/1WW/LED2 IP65 Rated 10-18 82 3000 100 40000 1/10 - 1.75”
BA15s 80692 $ N,1,4,5,6 JC10/1WW/BA15S/LED 10-18 82 3000 120 20000 1/40 - 2.01”
80810 $ N,1,4,6,10 JC10/1WW/BA15S/LED2 IP65 Rated 10-18 82 3000 100 40000 1/10 - 1.93”
Bulb Base Product
Number Footnotes Product
Code Description Volts CRI Color
Temp. Lumens Life Pkg.
Qty.
Beam
Spread MOL
VOLTS
Indicates the
product’s design
voltage of operation.
CRI
An international scale from
0 to 100 that indicates the
relative color rendering value
of a light source. The color
rendering index expresses the
degree to which colors will
look “natural” under a given
light source.
HOW TO READ A LED LAMP TABLE
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Solid State Lighting
45
LED LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Volts CRI Color
Temp. Lumens Life Pkg.
Qty.
Beam
Spread MOL
JC Type Lamps
1.5 WATT
JC10 G4 80693 $ 1,4,5,6 JC10/1WW/LED 10-18 82 3000 120 20000 1/40 - 1.21”
80776 $ 1,4,6,10 JC10/1WW/LED2 IP65 Rated 10-18 82 3000 100 40000 1/10 - 1.75”
BA15s 80692 $ N,1,4,5,6 JC10/1WW/BA15S/LED 10-18 82 3000 120 20000 1/40 - 1.70”
80810 $ N,1,4,6,10 JC10/1WW/BA15S/LED2 IP65 Rated 10-18 82 3000 100 40000 1/10 - 1.93”
1.8 WATT
JC20 G4 80782 $ 1,4,5,6 JC20/2AMB/LED Amber 10-18 - - - 20000 1/40 - 1.81”
80780 $ 1,4,5,6 JC20/2BLU/LED Blue 10-18 - - - 20000 1/40 - 1.81”
80779 $ 1,4,5,6 JC20/2GRN/LED Green 10-18 - - - 20000 1/40 - 1.81”
80781 $ 1,4,5,6 JC20/2RED/LED Red 10-18 - - - 20000 1/40 - 1.81”
2.4 WATT
JC20 G4 80690 $ 1,4,5,6 JC20/2WW/LED 10-18 82 3000 200 20000 1/40 - 1.81”
80815 $ 1,4,5,6 JC20/2NW/LED 10-18 72 5000 230 20000 1/40 - 1.81”
BA15s 80691 $ N,1,4,5,6 JC20/2WW/BA15S/LED 10-18 82 3000 200 20000 1/40 - 2.01”
2.5 WATT
JC20 G4 80774 $ 1,4,6,10 JC20/2WW/LED2 IP65 Rated 10-18 82 3000 140 40000 1/10 - 1.75”
BA15s 80775 $ N,1,4,6,10 JC20/2WW/BA15S/LED2 IP65 Rated 10-18 82 3000 140 40000 1/10 - 2.25”
4.5 WATT
JC35 G4 80830 $ 1,4,5,6 JC35/4WW/LED 10-18 82 3000 450 20000 1/30 - 2.03”
Elevator Lamps
2.6 WATT
R12 BA15d 80756 $ N,1,4,5,7 GBF/3WW/LED 10-18 82 2700 145 40000 1/10 31° 2.52”
BA15s 80701 $ N,1,4,5,7 1383/3WW/LED 10-18 82 2700 145 40000 1/10 31° 2.52”
Decorative Lamps
1 WATT
B10 Cand. 80172 3,4,5,7,8 B10CL1/827/LED Clear 120 82 2700 25 25000 1/25 - 3.77”
80173 3,4,5,7,8 B10CL1/724/LED Clear 120 72 2400 20 25000 1/25 - 3.77”
CA10 Cand. 80174 3,4,5,7,8 CA10CL1/827/LED Clear 120 82 2700 25 25000 1/25 - 4.00”
80175 3,4,5,7,8 CA10CL1/724/LED Clear 120 72 2400 20 25000 1/25 - 4.00”
2 WATT
B11 Cand. 80014 $ N,2,4,5,7,15 B11/2WW/LED Non-Dimmable 120 82 3000 65 40000 1/10 - 3.94”
3 WATT
B11 Cand. 80094 $ N,4,5,7,8,15 B11CL3/827/LED Cream Finish 120 82 2700 180 25000 1/10 - 3.78”
80789 $ N,4,5,7,8,15 B11CL3/827/BR/LED Brass Finish 120 82 2700 180 25000 1/10 - 3.78”
80790 $ N,4,5,7,8,15 B11CL3/827/CHR/LED Chrome Finish 120 82 2700 180 25000 1/10 - 3.78”
B10 B11
JC20
G4
B11
JC10
G4
JC20
BA15s
JC10
BA15s
JC
BA15S
IP65
JC
G4
IP65
JC35
G4
R12
BA15s
R12
BA15d CA10
LED lamp symbols, footnotes and abbreviations are located on page 54-55.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Solid State Lighting
46
LED LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Volts CRI Color
Temp. Lumens Life Pkg.
Qty.
Beam
Spread MOL
Decorative Lamps continued
4 WATT
A19 Med. 80149 $ N,3,4,5,7,8,15 A19FR4/827/LED A-Shape 120 82 2700 250 40000 1/6 - 4.25”
80150 $ N,3,4,5,7,8,15 A19FR4/830/LED A-Shape 120 82 3000 260 40000 1/6 - 4.25”
5 WATT
B11 Cand. 80820 $ N,3,4,5,7,8,15 B11CL5/827/LED Cream Finish 120 82 2700 300 25000 1/10 - 3.78”
Med. 80168 $ N,3,4,5,7,8,15 B11CL5/827/E26/LED Cream Finish 120 82 2700 300 25000 1/10 - 3.78”
A19 Med. 80020 $ N,3,4,5,7,8,15 A19FR5/830/LED A-Shape 120 82 3000 260 25000 1/6 - 4.25”
6 WATT
A19 GU24 80151 $ N,3,4,5,7,8,15 A19FR6/827/GU24/LED A-Shape 120 82 2700 450 40000 1/6 - 4.25”
Med. 80152 $ N,3,4,5,7,8,15 A19FR6/827/LED A-Shape 120 82 2700 450 40000 1/6 - 4.25”
80153 $ N,3,4,5,7,8,15 A19FR6/830/LED A-Shape 120 82 3000 470 40000 1/6 - 4.25”
80817 $ N,3,4,5,7,8,15 A19FR6/840/LED A-Shape 120 82 4000 490 40000 1/6 - 4.25”
80816 $ N,3,4,5,7,8,15 A19FR6/850/LED A-Shape 120 82 5000 510 40000 1/6 - 4.25”
8 WATT
A19 Med. 80022 $ N,3,4,5,7,8,15 A19FR8/830/LED A-Shape 120 82 3000 450 35000 1/6 - 4.25”
G25 Med. 80018 $ N,3,4,5,7,8,15 G25/8WW/LED Globe 120 82 3000 430 25000 1/6 - 4.25”
10 WATT
A19 Med. 80146 $ N,3,4,5,7,8,15 A19FR10/827/LED A-Shape 120 82 2700 800 25000 1/6 - 4.41”
80132 $ N,3,4,5,7,8,15 A19FR10/830/LED A-Shape 120 82 3000 830 40000 1/6 - 4.41”
A19 A19 B11
A19
GU24 G25
B11
E26
LED lamp symbols, footnotes and abbreviations are located on pages 54-55.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 47
Solid State Lighting
LED LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Volts CRI Color
Temp. Lumens CBCP Life Pkg.
Qty.
Beam
Spread MOL
MR16
GU10
MR11
MR11 and MR16 Lamps
2.2 WATT
MR11 GU4 80703 $ 1,4,5,6,7,8 MR11/2NW/FL/LED Flood 10-18 72 5000 150 420 40000 1/10 30° 1.42”
80705 $ 1,4,5,6,7,8 MR11/2WW/FL/LED Flood 10-18 82 2700 110 330 40000 1/10 30° 1.42”
80704 $ 1,4,5,6,7,8 MR11/2WW/NFL/LED Narrow Flood 10-18 82 2700 110 860 40000 1/10 18° 1.42”
3 WATT
MR16 GU5.3 80807 $ 1,4,5,6,7,8 MR16SP10/827/LED Spot 10-15 82 2700 140 1180 40000 1/10 15° 2.02”
80806 $ 1,4,5,6,7,8 MR16NFL10/827/LED Narrow Flood 10-15 82 2700 150 480 40000 1/10 25° 2.02”
80801 $ 1,4,5,6,7,8 MR16FL10/827/LED Flood 10-15 82 2700 150 300 40000 1/10 40° 2.02”
80808 $ 1,4,5,6,7,8 MR16WFL/827/LED Wide Flood 10-15 82 2700 140 170 40000 1/10 50° 2.02”
80813 $ 1,4,5,6,7,8 MR16FL10/750/LED Flood 10-15 72 5000 160 360 40000 1/10 40° 2.02”
80000 $ 1,4,5,6,7,8 MR16/3WW/FL/LED2 Flood 12 82 3000 150 360 40000 1/10 38° 1.97”
3.3 WATT
MR16 GU5.3 80709 $ 1,4,5,6,7,8 MR16/3WW/FL/LED Flood 10-18 82 2700 150 380 40000 1/10 34° 2.20”
3.5 WATT
MR11 BA15d 80169 $ 1,4,5,6,7,8 MR11FTD/827/LED Flood 10-15 82 2700 300 1135 40000 1/10 30° 1.89”
MR16 GU10 80742 $ 3,4,5,7,8 MR16/4NW/FL/GU10/LED Flood 120 72 5000 190 490 40000 1/10 29° 2.17”
80743 $ 3,4,5,7,8 MR16/4WW/FL/GU10/LED Flood 120 82 2700 140 370 40000 1/10 30° 2.17”
4 WATT
MR16 GU10 80819 $ 3,4,5,7,8 MR16FL4/830/GU10/LED Flood 120 82 3000 220 480 40000 1/10 40° 2.17”
GU5.3 80728 $ 1,4,5,6,7 MR16/5RGB/FL/LED Color Changing
Red, Green, Blue 10-18 - - - - 40000 1/10 31° 2.17”
80649 RGB/REMOTE Remote Control for Color Changing Lamps
4.5 WATT
MR16 GU5.3 80795 $ 1,4,5,6,7,8 MR16ESX/827/LED Spot 10-15 82 2700 200 1260 40000 1/10 15° 2.02”
80793 $ 1,4,5,6,7,8 MR16BBF/827/LED Narrow Flood 10-15 82 2700 220 750 40000 1/10 25° 2.02”
80792 $ 1,4,5,6,7,8 MR16BAB/827/LED Flood 10-15 82 2700 220 400 40000 1/10 40° 2.02”
80794 $ 1,4,5,6,7,8 MR16WFL20/827/LED Wide Flood 10-15 82 2700 200 240 40000 1/10 60° 2.02”
80811 $ 1,4,5,6,7,8 MR16BAB/750/LED Flood 10-15 72 5000 250 480 40000 1/10 40° 2.02”
80702 $ 1,4,5,6,7,8 MR16/3M4WW/FL/LED Flood 10-18 82 2700 220 560 40000 1/10 34° 2.20”
80724 $ 1,4,5,6,7 MR16/3M4AMB/NFL/LED Narrow Flood Amber 10-18 - - - - 40000 1/10 22° 2.20”
80727 $ 1,4,5,6,7 MR16/3M4BLU/NFL/LED Narrow Flood Blue 10-18 - - - - 40000 1/10 22° 2.20”
80726 $ 1,4,5,6,7 MR16/3M4GRN/NFL/LED Narrow Flood Green 10-18 - - - - 40000 1/10 22° 2.20”
80725 $ 1,4,5,6,7 MR16/3M4RED/NFL/LED Narrow Flood Red 10-18 - - - - 40000 1/10 22° 2.20”
MR16
MR11
BA15d
LED lamp symbols, footnotes and abbreviations are located on page 54-55.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
48
Solid State Lighting
LED LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Volts CRI Color
Temp. Lumens CBCP Life Pkg.
Qty.
Beam
Spread MOL
MR16 Lamps continued
6 WATT
MR16 GU5.3 80805 $ 1,4,5,6,7,8 MR16FRB/827/LED Spot 10-15 82 2700 320 1650 40000 1/10 18° 2.02”
80804 $ 1,4,5,6,7,8 MR16FRA/827/LED Narrow Flood 10-15 82 2700 350 1500 40000 1/10 25° 2.02”
80802 $ 1,4,5,6,7,8 MR16FMW/827/LED Flood 10-15 82 2700 350 600 40000 1/10 40° 2.02”
80809 $ 1,4,5,6,7,8 MR16WFL35/827/LED Wide Flood 10-15 82 2700 320 250 40000 1/10 60° 2.02”
80814 $ 1,4,5,6,7,8 MR16FMW/750/LED Flood 10-15 72 5000 410 720 40000 1/10 40° 2.02”
80016 $ 1,4,5,6,7,8 MR16FL6/830/LED Flood 10-15 82 3000 370 620 40000 1/10 40° 2.13”
GU10 80084 $ 1,4,5,6,7,8 MR16FL6/830/GU10/LED Flood 120 82 3000 370 620 40000 1/10 40° 3.11”
7 WATT
MR16 GU10 80167 $ 1,4,5,6,7,8 M16FL7/830/GU10/LED Flood 120 82 3000 520 1100 25000 1/10 40° 2.17”
8 WATT
MR16 GU5.3 80799 $ 1,4,5,6,7,8 MR16EXT/827/LED Spot 10-15 82 2700 450 2000 40000 1/10 18° 2.02”
80800 $ 1,4,5,6,7,8 MR16EXZ/827/LED Narrow Flood 10-15 82 2700 500 1700 40000 1/10 25° 2.02”
80798 $ 1,4,5,6,7,8 MR16EXN/827/LED Flood 10-15 82 2700 500 850 40000 1/10 40° 2.02”
80803 $ 1,4,5,6,7,8 MR16FNV/827/LED Wide Flood 10-15 82 2700 450 390 40000 1/10 60° 2.02”
80812 $ 1,4,5,6,7,8 MR16EXN/750/LED Flood 10-15 72 5000 580 1020 40000 1/10 40° 2.02”
PAR Lamps
3.3 WATT
PAR16 Med. 80748 $ N,3,4,5,7,8 PAR16/3NW/NFL/LED Narrow Flood 120 72 5000 160 460 40000 1/6 28° 2.99”
80749 $ N,3,4,5,7,8 PAR16/3WW/NFL/LED Narrow Flood 120 82 2700 145 370 40000 1/6 27° 2.99”
3.6 WATT
PAR16 Med. 80732 $ N,2,4,5,7 PAR16/4AMB/NFL/LED Narrow Flood Amber 120 - - - - 40000 1/6 22° 2.99”
80729 $ N,2,4,5,7 PAR16/4RED/NFL/LED Narrow Flood Red 120 - - - - 40000 1/6 22° 2.99”
4.5 WATT
PAR16 Med. 80731 $ N,2,4,5,7 PAR16/4GRN/NFL/LED Narrow Flood Green 120 - - - - 40000 1/6 22° 2.99”
6 WATT
PAR16 Med. 80078 $ 3,4,5,8,14,15 PAR16FL6/827/LED Flood 120 82 2700 360 670 40000 1/10 40° 3.27”
80080 $ 3,4,5,8,14,15 PAR16FL6/830/LED Flood 120 82 3000 370 690 40000 1/10 40° 3.27”
80082 $ 3,4,5,8,14,15 PAR16FL6/850/LED Flood 120 82 5000 400 750 40000 1/10 40° 3.27”
80698 $ N,3,4,5,7,8 PAR16/6NW/FL/LED2 Flood 120 72 5000 385 610 40000 1/10 40° 3.35”
80697 $ N,3,4,5,7,8 PAR16/6WW/FL/LED2 Flood 120 82 2700 310 530 40000 1/10 40° 3.35”
80720 $ N,3,4,5,7,8 PAR16/6WW/SP/LED2 Spot 120 82 2700 310 2370 40000 1/10 14° 3.35”
6.5 WATT
PAR36 MP
Term
80106 $ 1,4,7,13,16 PAR36/6WW/SP/LED Spot IP67 Rated 10-15 82 2700 260 1820 40000 1/6 15° 2.40”
80768 $ 1,4,7,13,16 PAR36/6WW/WFL/LED2 Wide Flood IP67
Rated 10-15 82 2700 260 680 40000 1/6 32° 2.40”
PAR16PAR16
PAR36
IP67
MR16
GU10MR16
LED lamp symbols, footnotes and abbreviations are located on pages 54-55.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 49
Solid State Lighting
LED LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Volts CRI Color
Temp. Lumens CBCP Life Pkg.
Qty.
Beam
Spread MOL
PAR30
Short Neck PAR30 PAR36
RGB
PAR20 PAR20 PAR20
PAR Lamps continued
7.2 WATT
PAR20 Med. 80736 $ N,2,4,5,7 PAR20/7AMB/NFL/LED Narrow Flood Amber 120 - - - - 40000 1/6 25° 3.43”
8 WATT
PAR20 Med. 80072 $ 3,4,5,8,14,15 PAR20FL8/830/LED Flood 120 82 3000 380 600 40000 1/6 40° 3.43”
80070 $ 3,4,5,8,14,15 PAR20NFL8/827/LED Narrow Flood 120 82 2700 365 1250 40000 1/6 25° 3.43”
80024 $ 3,4,5,8,14,15 PAR20NFL8/830/LED Narrow Flood 120 82 3000 380 1300 25000 1/6 25° 3.43”
80074 $ 3,4,5,8,14,15 PAR20NFL8/840/LED Narrow Flood 120 82 4000 395 1350 40000 1/6 25° 3.43”
80076 $ 3,4,5,8,14,15 PAR20NFL8/850/LED Narrow Flood 120 82 5000 410 1400 40000 1/6 25° 3.43”
80638 $ N,2,4,5,7 PAR20/8RGB/NFL/LED Color Changing
Red, Green, Blue 120 - - - - 40000 1/6 25° 3.50”
80649 PAR20/8RGB/REMOTE Remote Control for Color Changing Lamps
10 WATT
PAR36 MP
Term
80783 $ 1,4,7,13,16 PAR36/10WW/SP/LED Spot IP67 Rated 10-15 82 2700 420 4200 40000 1/6 15° 2.40”
80769 $ 1,4,7,13,16 PAR36/10WW/WFL/LED2 Wide Flood,
Amber IP67 Rated 10-15 82 2700 420 920 40000 1/6 32° 2.40”
80784 $ 1,4,7,13,16 PAR36/10AMB/WFL/LED Wide Flood,
Amber IP67 Rated 10-15 - - - - 40000 1/6 32° 2.40”
80786 $ 1,4,7,13,16 PAR36/10BLU/WFL/LED Wide Flood,
Blue IP67 Rated 10-15 - - - - 40000 1/6 32° 2.40”
80785 $ 1,4,7,13,16 PAR36/10GRN/WFL/LED Wide Flood,
Green IP67 Rated 10-15 - - - - 40000 1/6 32° 2.40”
80787 $ 1,4,7,13,16 PAR36/10RED/WFL/LED Wide Flood,
Red IP67 Rated 10-15 - - - - 40000 1/6 32° 2.40”
13 WATT
PAR30 Med. 80066 $ 3,4,5,8,14,15 PAR30FL13/827/LED Flood 120 82 2700 680 1250 40000 1/6 40° 4.49”
80026 $ 3,4,5,8,14,15 PAR30FL13/830/LED Flood 120 82 3000 700 1280 25000 1/6 40° 4.49”
80068 $ 3,4,5,8,14,15 PAR30FL13/840/LED Flood 120 82 4000 730 1340 40000 1/6 40° 4.49”
80030 $ 3,4,5,8,14,15 PAR30FL13/850/LED Flood 120 82 5000 760 1360 40000 1/6 40° 4.49”
80096 $ 3,4,5,8,14,15 PAR30NFL13/827/LED Narrow Flood 120 82 2700 680 2910 40000 1/6 25° 4.49”
80028 $ 3,4,5,8,14,15 PAR30NFL13/830/LED Narrow Flood 120 82 3000 700 3000 40000 1/6 25° 4.49”
80038 $ 3,4,5,8,14,15 PAR30NFL13/850/LED Narrow Flood 120 82 5000 760 3250 40000 1/6 25° 4.49”
80102 $ 3,4,5,8,14,15 PAR30SP13/827/LED Spot 120 82 2700 680 4900 40000 1/6 15° 4.49”
80098 $ 3,4,5,8,14,15 PAR30SP13/830/LED Spot 120 82 3000 700 5100 40000 1/6 15° 4.49”
80100 $ 3,4,5,8,14,15 PAR30SP13/850/LED Spot 120 82 5000 760 5500 40000 1/6 15° 4.49”
14 WATT
PAR36 MP
Term 80165 $ 1,4,5,6,7,8,17 PAR36FL14/827/LED Flood 12 82 2700 870 1830 40000 1/6 32° 2.40”
15 WATT
PAR30
Short
Med. 80142 $ 3,4,8,14,15 PAR30FL15S/827/LED Flood 120 82 2700 770 1500 40000 1/6 40° 3.75”
80138 $ 3,4,8,14,15 PAR30FL15S/830/LED Flood 120 82 3000 800 1600 25000 1/6 40° 3.75”
PAR36
IP67
LED lamp symbols, footnotes and abbreviations are located on page 54-55.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T8 Med
Bi-Pin
S14
S14 Clear
50
Solid State Lighting
LED LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Volts CRI Color
Temp. Lumens CBCP Life Pkg.
Qty.
Beam
Spread MOL
PAR Lamps continued
16 WATT
PAR38 Med. 80040 $ 3,4,5,8,14,15 PAR38FL16/827/LED Flood 120 82 2700 920 1700 40000 1/6 40° 5.00”
80032 $ 3,4,5,8,14,15 PAR38FL16/830/LED Flood 120 82 3000 950 1770 25000 1/6 40° 5.00”
80044 $ 3,4,5,8,14,15 PAR38FL16/840/LED Flood 120 82 4000 990 1850 40000 1/6 40° 5.00”
80036 $ 3,4,5,8,14,15 PAR38FL16/850/LED Flood 120 82 5000 1020 1930 40000 1/6 40° 5.00”
80034 $ 3,4,5,8,14,15 PAR38NFL16/830/LED Narrow Flood 120 82 3000 950 4000 40000 1/6 25° 5.00”
80042 $ 3,4,5,8,14,15 PAR38SP16/830/LED Spot 120 82 3000 950 6700 40000 1/6 15° 5.00”
18 WATT
PAR36 MP
Term
80788 $ 1,4,7,13,16 PAR36/18WW/SP/LED2 Spot IP67 Rated 10-15 82 2700 720 3000 40000 1/6 20° 2.40”
80770 $ 1,4,7,13,16 PAR36/18WW/WFL/LED2 Wide Flood IP67
Rated 10-15 82 2700 720 1800 40000 1/6 32° 2.40”
20 WATT
PAR38 Med. 80050 $ 3,4,5,8,14,15 PAR38FL20/827/LED Flood 120 82 2700 1150 1970 40000 1/6 40° 5.00”
80056 $ 3,4,5,8,14,15 PAR38FL20/830/LED Flood 120 82 3000 1200 2050 25000 1/6 40° 5.00”
80058 $ 3,4,5,8,14,15 PAR38FL20/840/LED Flood 120 82 4000 1250 2150 40000 1/6 40° 5.00”
80064 $ 3,4,5,8,14,15 PAR38FL20/850/LED Flood 120 82 5000 1300 2200 40000 1/6 40° 5.00”
80048 $ 3,4,5,8,14,15 PAR38NFL20/827/LED Narrow Flood 120 82 2700 1150 4850 40000 1/6 25° 5.00”
80054 $ 3,4,5,8,14,15 PAR38NFL20/830/LED Narrow Flood 120 82 3000 1200 5000 40000 1/6 25° 5.00”
80062 $ 3,4,5,8,14,15 PAR38NFL20/850/LED Narrow Flood 120 82 5000 1300 5400 40000 1/6 25° 5.00”
80046 $ 3,4,5,8,14,15 PAR38SP20/827/LED Spot 120 82 2700 1150 7700 40000 1/6 15° 5.00”
80052 $ 3,4,5,8,14,15 PAR38SP20/830/LED Spot 120 82 3000 1200 8100 40000 1/6 15° 5.00”
80060 $ 3,4,5,8,14,15 PAR38SP20/850/LED Spot 120 82 5000 1300 8700 40000 1/6 15° 5.00”
Linear Lamps
18 WATT
T8 Bi-Pin 80170 $ 2,4,5 T8FR18/840/LED Linear T8 Tube 120-
277 82 4000 1800 - 40000 1/12 120° 48”
80171 $ 2,4,5 T8FR18/850/LED Linear T8 Tube 120-
277 82 5000 1800 - 40000 1/12 120° 48”
Sign Lamps
1.4 WATT
S14 Med. 80517 3,4,7,8,10 S14RED1C/LED Red IP65 Rated 120 - - - - 40000 1/25 - 3.35”
80518 3,4,7,8,10 S14BLU1C/LED Blue IP65 Rated 120 - - - - 40000 1/25 - 3.35”
80519 3,4,7,8,10 S14GRN1C/LED Green IP65 Rated 120 - - - - 40000 1/25 - 3.35”
80520 3,4,7,8,10 S14YEL1C/LED Yellow IP65 Rated 120 - - - - 40000 1/25 - 3.35”
80521 3,4,7,8,10 S14WH1C/LED White IP65 Rated 120 - - - - 40000 1/25 - 3.35”
80522 3,4,7,8,10 S14CL1/827/LED Clear IP65 Rated 120 82 2700 35 - 40000 1/25 - 3.35”
PAR36PAR38
LED lamp symbols, footnotes and abbreviations are located on pages 54-55.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Solid State Lighting
51
LED LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Volts CRI Color
Temp. Lumens Life Pkg.
Qty.
Beam
Spread MOL
BR40 BR30 BR30 R20
Reector Lamps
5 WATT
R20 Med. 80108 $ 3,4,5,8,14,15 R20FL5/830/LED Flood 120 82 3000 310 40000 1/6 - 3.94”
80110 $ 3,4,5,8,14,15 R20FL5/850/LED Flood 120 82 5000 335 40000 1/6 - 3.94”
8 WATT
R20 Med. 80818 $ 3,4,5,8,14,15 R20FL8/827/LED Flood 120 82 2700 500 25000 1/6 - 3.94”
80112 $ 3,4,5,8,14,15 R20FL8/830/LED Flood 120 82 3000 520 25000 1/6 - 3.94”
80114 $ 3,4,5,8,14,15 R20FL8/850/LED Flood 120 82 5000 560 40000 1/6 - 3.94”
9 WATT
BR30 GU24 80158 $ 3,4,5,8,14,15 BR30FL9/827/GU24/LED Flood 120 82 2700 650 40000 1/6 - 5.12”
Med. 80159 $ 3,4,5,8,14,15 BR30FL9/827/LED Flood 120 82 2700 650 25000 1/6 - 5.12”
80160 $ 3,4,5,8,14,15 BR30FL9/830/LED Flood 120 82 3000 670 40000 1/6 - 5.12”
80161 $ 3,4,5,8,14,15 BR30FL9/840/LED Flood 120 82 4000 700 40000 1/6 - 5.12”
80162 $ 3,4,5,8,14,15 BR30FL9/850/LED Flood 120 82 5000 730 40000 1/6 - 5.12”
80166 $ 3,4,5,8,14,15 BR0FL9/PNK/LED Flood Pink 120 - - - 40000 1/6 - 5.12”
11 WATT
BR30 Med. 80086 $ 3,4,5,8,14,15 BR30FL11/827/LED Flood 120 82 2700 730 25000 1/6 - 5.12”
80088 $ 3,4,5,8,14,15 BR30FL11/830/LED Flood 120 82 3000 750 25000 1/6 - 5.12”
80090 $ 3,4,5,8,14,15 BR30FL11/840/LED Flood 120 82 4000 780 40000 1/6 - 5.12”
80092 $ 3,4,5,8,14,15 BR30FL11/850/LED Flood 120 82 5000 810 40000 1/6 - 5.12”
13 WATT
BR40 Med. 80116 $ 3,4,5,8,14,15 BR40FL13/827/LED Flood 120 82 2700 850 25000 1/6 - 6.46”
80118 $ 3,4,5,8,14,15 BR40FL13/830/LED Flood 120 82 3000 880 25000 1/6 - 6.46”
80120 $ 3,4,5,8,14,15 BR40FL13/840/LED Flood 120 82 4000 920 40000 1/6 - 6.46”
80122 $ 3,4,5,8,14,15 BR40FL13/850/LED Flood 120 82 5000 950 40000 1/6 - 6.46”
15 WATT
BR30 Med. 80778 $ 3,4,5,8,14,15 BR30/15WW/FL/LED Flood 120 82 3000 860 25000 1/6 - 5.28”
18 WATT
BR40 Med. 80124 $ 3,4,5,8,14,15 BR40FL18/827/LED Flood 120 82 2700 1200 40000 1/6 - 6.46”
80126 $ 3,4,5,8,14,15 BR40FL18/830/LED Flood 120 82 3000 1230 25000 1/6 - 6.46”
80128 $ 3,4,5,8,14,15 BR40FL18/840/LED Flood 120 82 4000 1280 40000 1/6 - 6.46”
80130 $ 3,4,5,8,14,15 BR40FL18/850/LED Flood 120 82 5000 1320 40000 1/6 - 6.46”
Pool Bright
8 WATT
R20 Med. 80822 $ 3,4,5,11 R20FL8/POOL/12V/LED Pool Bright 12 82 6500 1000* 40000 6/24 - 3.94”
80821 $ 3,4,5,11 R20FL8/POOL/LED Pool Bright 120 82 6500 1000* 40000 6/24 - 3.94”
BR30
GU24
*Scotopic Lumens
LED lamp symbols, footnotes and abbreviations are located on page 54-55. TOC
Solid State Lighting
52
LED LAMPS
Pool Bright continued
18 WATT
R40 Med. 80136 $ 3,4,5,11 R40FL18/POOL/12V/LED Pool Bright 12 82 6500 3150* 40000 6/24 - 6.46”
80134 $ 3,4,5,11 R40FL18/POOL/LED Pool Bright 120 82 6500 3150* 40000 6/24 - 6.46”
Miniatures
1 WATT
Mini
Wedge
80791 $ 1,4,5,6 912/1WW/LED 10-18 82 3000 50 20000 1/50 - 1.18”
2.5 WATT
Plastic
Wedge 80777 $ 1,4,5,6,10 3155/2WW/LED IP65 Rated 10-18 82 3000 140 40000 1/10 - 2.40”
Watts Product
Number Footnotes Product
Code Description Color
Temp.
Pkg.
Qty.
Headlamp
0.75 80920 12 HL/18LED 18 LED Water Resistant Headlamp - Requires 3 AAA Batteries 6000 50/200
C7 C9 3155 912
Bulb Base Product
Number Footnotes Product
Code Description Volts CRI Color
Temp. Lumens Life Pkg.
Qty.
Beam
Spread MOL
BR40
R40
C7 and C9 Lamps
0.96 WATT
C7 Cand. 80510 $ N,2,4,7,10 C7NW/FC/LED Clear Faceted 120 6000 60000 10/200 1.30”
80516 $ N,2,4,7,10 C7WW/FC/LED Clear Faceted 120 2700 60000 10/200 1.30”
80508 $ N,2,4,7,10 C7BLU/FC/LED Blue Faceted 120 - 60000 10/200 1.30”
80509 $ N,2,4,7,10 C7GRN/FC/LED Green Faceted 120 - 60000 10/200 1.30”
80506 $ N,2,4,7,10 C7RED/FC/LED Red Faceted 120 - 60000 10/200 1.30”
80507 $ N,2,4,7,10 C7YEL/FC/LED Yellow Faceted 120 - 60000 10/200 1.30”
C9 Int. 80515 $ N,2,4,7,10 C9CL/FC/LED Clear Faceted 120 6000 60000 10/200 1.60”
80513 $ N,2,4,7,10 C9BLU/FC/LED Blue Faceted 120 - 60000 10/200 1.60”
80514 $ N,2,4,7,10 C9GRN/FC/LED Green Faceted 120 - 60000 10/200 1.60”
80511 $ N,2,4,7,10 C9RED/FC/LED Red Faceted 120 - 60000 10/200 1.60”
80512 $ N,2,4,7,10 C9YEL/FC/LED Yellow Faceted 120 - 60000 10/200 1.60”
Bulb Base Product
Number Footnotes Product
Code Description Volts Color
Temp. Life Pkg.
Qty. MOL
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
LED lamp symbols, footnotes and abbreviations are located on page 54-55.
*Scotopic Lumens
TOCTOC
PAR20
(RGB Only)
C7 R12
BA15s
PAR36
IP67
PAR36
B10
Medium
E26
G4 SC Bayonet
BA15s
DC Bayonet
BA15d
A19
R12
BA15d
GU10
PAR20
Candelabra
E12
Intermediate
E17
MP-Term
C9
PAR16
(Colors Only)
MR11 MR16
GU10
A19 B11
PAR20PAR16 PAR30
Short Neck
PAR30 PAR38
JC20
BA15s
JC10JC20
Globe
S14 Clear
JC10
BA15s
JC G4
IP65
JC
BA15s
IP65
Plastic
Wedge
Wedge
BR40/R40 BR30 BR30 R20 Plastic
Wedge
Mini
Wedge
A19
GU24
BR30
GU24
B11
GU5.3
MR16
Medium
Bi-Pin
G13
JC35
T8 Medium
Bi-Pin
GU24
Bulb Shapes
Base Types
Bulb and Base Identication Guide
CA10
S14
53
LED LAMPS
MR11
BA15d
Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOCTOC
54
Symbols, Footnotes and Abbreviations
LED LAMPS
SYMBOLS
New product introduced within the past year.
NNickel-plated brass base.
$Energy saving product.
XProduct will be discontinued when inventory is depleted.
FOOTNOTES
1
This device is intended for use on Class 2 circuits only. Use only on low voltage circuits with output
ranges identied in specications. These lamps may be dimmed using analog dimmers and magnetic
transformers. May not be compatible with all dimmers and/or transformers and should be tested in
application for compatibility prior to full installations on circuits using such devices. Not for use on timing
devices, photo sensors or occupancy sensors.
2Non-Dimmable 120V lamps should only be used on 120V circuits. Not for use on dimmers, timing devices,
photo sensors or occupancy sensors.
3
Dimmable 120V lamps should only be used on 120V circuits. Lamps are designed for use with an analog
dimmer and these products may not be compatible with all dimming devices. Lamps should be tested in
the application prior to full installations on circuits using such devices. Not for use on timing devices, photo-
sensors, digital dimmers or occupancy sensors. Ensure minimum dimmer load is met for best performance.
4
Caution: Risk of electric shock. Never disassemble or modify the bulb, no user serviceable parts inside.
To avoid burns, do not touch the bulb during operation and allow to cool completely after switching off.
This device is not intended for use in emergency exit xtures. This device complies with Part 18 of the FCC
rules. This product may cause interference with other devices. If interference occurs, change the location
of the products involved.
5Do not use where directly exposed to water.
6Approved for use in sealed metal landscape xtures.
7Do not use in totally enclosed xtures or IC or ICAT rated recessed cans.
8Dimmable lamps dim down to 5%, but are limited by the dimming device range.
9Base down operation only.
10 IP65 Rated – this lamp is rated for use outdoors where exposed directly to water from rain or irrigation.
The lamp is not submersible, not for enclosed xtures.
11 This product is designed to allow operation in metal construction pool xtures and is
allowed in this type of enclosed xture.
12 Batteries not included.
13 IP67 Rated - This lamp is rated for use outdoors where exposed directly to water and protected
from the effects of temporary immersion in water to depth between 5.9” (15cm) and 39.37” (1m).
14 Not for use in totally enclosed xtures.
Acceptable for use in insulated contact airtight (ICAT) rated xtures
15 Lamp is UL approved for damp locations.
16 Rated for outdoor use only.
17 Rated for indoor use only.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
55
LED LAMPS
Symbols, Footnotes and Abbreviations
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
ABBREVIATIONS
724 Refers to a color temperature of 2400K and 72CRI.
750 Refers to a color temperature of 5000K and 72CRI.
827 Refers to a color temperature of 2700K and 82CRI.
830 Refers to a color temperature of 3000K and 82CRI.
840 Refers to a color temperature of 4000K and 82CRI.
850 Refers to a color temperature of 5000K and 82CRI.
AMB Code abbreviation for an Amber lamp.
BA15S Code abbreviation for a lamp with a BA15s base.
BLU Code abbreviation for a Blue lamp.
BR Code abbreviation for a lamp with a Brass base.
CCode abbreviation for lamp with Ceramic Paint Color.
CHR Code abbreviation for a lamp with a Chrome base.
CL Code abbreviation for a Clear lamp.
E26 Code abbreviation for a lamp with a E26 base.
FL Code abbreviation for Flood lamps.
FR Code abbreviation for a Frosted lamp.
GRN Code abbreviation for a Green lamp.
GU10 Code abbreviation for a lamp with a GU10 base.
GU24 Code abbreviation for a lamp with a GU24 base.
NFL Code abbreviation for Narrow Flood lamps.
NW Code abbreviation for a lamp with a color temperature of 5000K.
POOL Code abbreviation for a Pool Bright lamp.
RED Code abbreviation for a Red lamp.
RGB Code abbreviation for a Color Changing Red, Green and Blue lamp.
SCode abbreviation for short neck PAR30 lamp.
SP Code abbreviation for Spot lamps.
WFL Code abbreviation for Wide Flood lamps.
WH Code abbreviation for a White lamp.
WW Code abbreviation for a lamp with a color temperature of 2700K.
YEL Code abbreviation for a Yellow lamp.
TOC
®
COMPACT FLUORESCENT LAMPS
How to Read a Table
Bare Spiral Lamps
Reector Lamps
Decorative Lamps
Single Tube 2-Pin Lamps
Single Tube 4-Pin Lamps
Double Tube 2-Pin Lamps
Double Tube 4-Pin Electronic Lamps
Triple Tube 4-Pin Electronic Lamps
High Lumen Long 4-Pin Lamps
Flat Quad 4-Pin Electronic Lamps
Bulb and Base Identication
Cross Reference Guide
Symbols, Footnotes and Abbreviations
CONTENTS
58
59
63
64
65
65
65
66
66
68
68
69
70
73
TOC
HOW TO READ A COMPACT FLUORESCENT
LAMP TABLE
BULB
Designations indicate shape and size.
Illustrations can be found on page 69
and at the top of each page.
BASE
Indicates base type.
Full base descriptions
and illustrations can
be found on page 69.
PACKAGE QUANTITY
Indicates minimum sell quantity
and smallest shipping carton.
PRODUCT CODE
Abbreviated product description
can also be used for ordering.
A key to abbreviations can be
found on page 74.
WATTS
Indicates the
power consumed
by the lamp during
operation.
PRODUCT
NUMBER
Use this number when
placing an order.
MOD
Indicates
maximum
overall
diameter
in inches.
FOOTNOTES &
SYMBOLS
Related footnotes can
be found on page 73.
LUMENS
Represents
average
light output.
DESCRIPTION
Bulb nish and other
important information.
MOL
Indicates
maximum
overall length
in inches.
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Lumens Avg.
Life MOL MOD
CFL Reector
11 WATT
PAR20 Med. 46005 $ 2,4,8 CFL11/27/PAR20 Warm White Flood 6/24 2700 82 380 10000 3.86” 2.48”
46006 $ 2,4,8 CFL11/35/PAR20 White Flood 6/24 3500 82 380 10000 3.86” 2.48”
46007 $ 2,4,8 CFL11/41/PAR20 Cool White Flood 6/24 4100 82 380 10000 3.86” 2.48”
46008 $ 2,4,8 CFL11/50/PAR20 Natural White Flood 6/24 5000 82 380 10000 3.86” 2.48”
R20 GU24 46542 $ 2,4,8 CFL11/27/R20/GU24 Warm White Flood 6/24 2700 82 340 10000 4.02” 2.50”
AVERAGE
LIFE
Average rated life
expressed in hours.
COLOR
TEMP.
A term used to
describe the
color of a light
source and is
expressed in
degrees
“Kelvin” (K).
CRI
An international
scale from 0 to 100
that indicates the
relative color rendering
value of a light source.
The color rendering
index expresses the
degree to which colors
will look “natural” under
a given light source.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 59
COMPACT FLUORESCENT LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Lumens Avg.
Life MOL MOD
CFL Bare Spiral
5 WATT
T2 Cand. 45011 $,1,3,4 CFL5/27/E12 Warm White 10/50 2700 82 250 10000 3.50” 1.38”
45015 X $ 1,3,4 CFL5/35/E12 White 10/50 3500 82 250 10000 3.50” 1.38”
45017 X $ 1,3,4 CFL5/41/E12 Cool White 10/50 4100 82 250 10000 3.50” 1.38”
45019 X $ 1,3,4 CFL5/50/E12 Natural White 10/50 5000 82 250 10000 3.50” 1.38”
Med. 45010 $ 1,3,4 CFL5/27 Warm White 10/50 2700 82 250 10000 3.56” 1.38”
46600 X $ 1,3,4 CFL5/27/FS Warm White Full Spiral 10/50 2700 82 300 12000 2.98” 1.93”
45014 X $ 1,3,4 CFL5/35 White 10/50 3500 82 250 10000 3.56” 1.38”
45016 $ 1,3,4 CFL5/41 Cool White 10/50 4100 82 250 10000 3.56” 1.38”
45018 $ 1,3,4 CFL5/50 Natural White 10/50 5000 82 250 10000 3.56” 1.38”
9 WATT
T2 Cand. 45031 $ 1,3,4 CFL9/27/E12 Warm White 10/50 2700 82 500 10000 4.00” 1.57”
45035 X $ 1,3,4 CFL9/35/E12 White 10/50 3500 82 500 10000 4.00” 1.57”
45037 X $ 1,3,4 CFL9/41/E12 Cool White 10/50 4100 82 500 10000 4.00” 1.57”
45039 X $ 1,3,4 CFL9/50/E12 Natural White 10/50 5000 82 500 10000 4.00” 1.57”
Med. 45030 $ 1,3,4 CFL9/27 Warm White 10/50 2700 82 500 10000 4.06” 1.57”
46605 X $ 1,3,4 CFL9/27/FS Warm White Full Spiral 10/50 2700 82 500 12000 3.41” 1.93”
45034 $ 1,3,4 CFL9/35 White 10/50 3500 82 500 10000 4.06” 1.57”
45036 $ 1,3,4 CFL9/41 Cool White 10/50 4100 82 500 10000 4.06” 1.57”
45038 X $ 1,3,4 CFL9/50 Natural White 10/50 5000 82 500 10000 4.06” 1.57”
11 WATT
T3 Med. 109240 $ 1,3,4 CFL11/27 Warm White 10/50 2700 82 700 12000 4.29” 1.85”
109242 $ 1,3,4 CFL11/41 Cool White 10/50 4100 82 700 12000 4.29” 1.85”
109244 $ 1,3,4 CFL11/50 Natural White 10/50 5000 82 700 12000 4.29” 1.85”
109224 $ 1,3,4 CFL11/BLU Blue 10/50 - - - 8000 4.29” 1.85”
109226 X $ 1,3,4 CFL11/GRN Green 10/50 - - - 8000 4.29” 1.85”
109220 $ 1,3,4 CFL11/RED Red 10/50 - - - 8000 4.29” 1.85”
109222 $ 1,3,4 CFL11/YEL Yellow 10/50 - - - 8000 4.29” 1.85”
13 WATT
T2 Cand. 45052 $ 1,3,4 CFL13/27/T2/E12 Warm White 10/50 2700 82 900 10000 4.19” 1.81”
45055 $ 1,3,4 CFL13/35/T2/E12 White 10/50 3500 82 900 10000 4.19” 1.81”
45057 $ 1,3,4 CFL13/41/T2/E12 Cool White 10/50 4100 82 850 10000 4.19” 1.81”
45059 $ 1,3,4 CFL13/50/T2/E12 Natural White 10/50 5000 82 900 10000 4.19” 1.81”
Med. 45049 $ 1,3,4 CFL13/27/T2 Warm White 10/50 2700 82 900 12000 4.19” 1.81”
45071 $ 1,3,4 CFL13/27/T2/4PK Warm White 4-Pack 20/60 2700 82 900 12000 4.19” 1.81”
Self-Ballasted
®
Spiral
Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
60
COMPACT FLUORESCENT LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Lumens Avg.
Life MOL MOD
®
CFL Bare Spiral continued
13 WATT continued
T2 Med. 46610 $ 1,3,4 CFL13/27/FS Warm White Full Spiral 10/50 2700 82 840 12000 3.84” 1.93”
45054 $ 1,3,4 CFL13/35/T2 White 10/50 3500 82 900 10000 4.19” 1.81”
45056 $ 1,3,4 CFL13/41/T2 Cool White 10/50 4100 82 850 10000 4.19” 1.81”
45073 $ 1,3,4 CFL13/41/T2/4PK Cool White 4-Pack 20/60 4100 82 850 10000 4.19” 1.81”
45058 $ 1,3,4 CFL13/50/T2 Natural White 10/50 5000 82 900 10000 4.19” 1.81”
GU24 46506 $ 1,3,4 CFL13/27/GU24 Warm White 10/50 2700 82 800 10000 3.63” 1.81”
46525 $ 1,3,4 CFL13/35/GU24 White 10/50 3500 82 800 10000 3.63” 1.81”
46526 $ 1,3,4 CFL13/41/GU24 Cool White 10/50 4100 82 800 10000 3.63” 1.81”
46527 $ 1,3,4 CFL13/50/GU24 Natural White 10/50 5000 82 800 10000 3.63” 1.81”
T3 Med. 45101 $ 1,3,4 CFL13/27 Warm White 10/50 2700 82 900 10000 4.41” 1.97”
45103 $ 1,3,4 CFL13/35 White 10/50 3500 82 900 10000 4.41” 1.97”
45104 $ 1,3,4 CFL13/41 Cool White 10/50 4100 82 900 10000 4.41” 1.97”
45105 $ 1,3,4 CFL13/50 Natural White 10/50 5000 82 900 10000 4.41” 1.97”
45107 $ 1,3,4 CFL13/65 Daylight 10/50 6500 82 850 10000 4.41” 1.97”
GU24 46544 $ 3,5,6 CFL13/27/GU24/DIM Warm White Dimmable 10/50 2700 82 800 10000 4.00” 1.81”
13/20/25 WATT
T3 Med. 45720 $ 4,5,8 CFL25/27/3WAY Warm White 3-Way 10/50 2700 82
900/
1200/
1600 8000 6.13” 2.36”
45721 $ 4,5,8 CFL25/41/3WAY Cool White 3-Way 10/50 4100 82
900/
1200/
1600 8000 6.13” 2.36”
15 WATT
T3 Med. 109252 $ 4,5,8 CFL15/27 Warm White 10/50 2700 82 950 10000 4.94” 1.85”
109330 $ 4,5,8 CFL15/35 White 10/50 3500 82 950 10000 4.94” 1.85”
109261 $ 4,5,8 CFL15/41 Cool White 10/50 4100 82 950 10000 4.94” 1.85”
109272 $ 4,5,8 CFL15/50 Natural White 10/50 5000 82 950 10000 4.94” 1.85”
109270 $ 4,5,8 CFL15/BLB Blacklight-Blue 1/20 - - - 12000 4.94” 1.85”
109288 $ 4,5,8 CFL15/YEL Yellow 1/50 - - - 12000 4.94” 1.85”
46330 $ 1,3,6 CFL15/27/DIM Warm White Dimmable 10/50 2700 82 900 10000 4.92” 1.81”
18 WATT
T2 Med. 45062 $ 1,3,4 CFL18/27/T2 Warm White 10/50 2700 82 1100 10000 4.56” 2.13”
45064 $ 1,3,4 CFL18/35/T2 White 10/50 3500 82 1100 10000 4.56” 2.13”
45065 $ 1,3,4 CFL18/41/T2 Cool White 10/50 4100 82 1100 10000 4.56” 2.13”
45066 $ 1,3,4 CFL18/50/T2 Natural White 10/50 5000 82 1100 10000 4.56” 2.13”
GU24 46512 $ 1,3,4 CFL18/27/GU24 Warm White 10/50 2700 82 1200 10000 3.90” 2.13”
46519 $ 1,3,4 CFL18/35/GU24 White 10/50 3500 82 1200 10000 3.90” 2.13”
46520 $ 1,3,4 CFL18/41/GU24 Cool White 10/50 4100 82 1200 10000 3.90” 2.13”
46521 $ 1,3,4 CFL18/50/GU24 Natural White 10/50 5000 82 1200 10000 3.90” 2.13”
®
Spiral
GU24 Spiral
Self-Ballasted
Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 61
COMPACT FLUORESCENT LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Lumens Avg.
Life MOL MOD
CFL Bare Spiral continued
18 WATT continued
T3 Med. 45120 $ 1,3,4 CFL18/27 Warm White 10/50 2700 82 1200 12000 5.24” 2.05”
45122 $ 1,3,4 CFL18/35 White 10/50 3500 82 1200 12000 5.24” 2.05”
45123 $ 1,3,4 CFL18/41 Cool White 10/50 4100 82 1200 12000 5.24” 2.05”
45124 $ 1,3,4 CFL18/50 Natural White 10/50 5000 82 1200 12000 5.24” 2.05”
GU24 46546 $ 3,5,6 CFL18/27/GU24/DIM Warm White Dimmable 10/50 2700 82 1200 10000 4.40”” 2.05”
20 WATT
T3 Med. 109254 $ 1,3,4 CFL20/27 Warm White 10/50 2700 82 1250 12000 5.25” 2.05”
109263 $ 1,3,4 CFL20/41 Cool White 10/50 4100 82 1250 12000 5.25” 2.05”
109274 $ 1,3,4 CFL20/50 Natural White 10/50 5000 82 1250 12000 5.25” 2.05”
23 WATT
T2 Med. 45075 $ 1,3,4 CFL23/27/T2 Warm White 10/50 2700 82 1600 10000 4.92” 2.13”
46620 X $ 1,3,4 CFL23/27/FS Warm White 10/50 2700 82 1600 12000 4.65” 2.28”
45077 $ 1,3,4 CFL23/41/T2 Cool White 10/50 4100 82 1600 10000 4.92” 2.13”
45079 $ 1,3,4 CFL23/50/T2 Natural White 10/50 5000 82 1600 10000 4.92” 2.13”
GU24 46518 $ 1,3,4 CFL23/27/GU24 Warm White 10/50 2700 82 1600 10000 4.41” 2.13”
46522 $ 1,3,4 CFL23/35/GU24 White 10/50 3500 82 1600 10000 4.41” 2.13”
46523 $ 1,3,4 CFL23/41/GU24 Cool White 10/50 4100 82 1600 10000 4.41” 2.13”
46524 $ 1,3,4 CFL23/50/GU24 Natural White 10/50 5000 82 1600 10000 4.41” 2.13”
T3 Med. 45250 $ 1,3,4 CFL23/27 Warm White 10/50 2700 82 1600 10000 5.04” 2.05”
46334 $ 4.5,6,8 CFL23/27/DIM Warm White Dimmable 10/50 2700 82 1600 10000 5.59” 2.13”
45252 $ 1,3,4 CFL23/35 White 10/50 3500 82 1600 10000 5.04” 2.05”
45253 $ 1,3,4 CFL23/41 Cool White 10/50 4100 82 1600 10000 5.04” 2.05”
45254 $ 1,3,4 CFL23/50 Natural White 10/50 5000 82 1600 10000 5.04” 2.05”
GU24 46548 $ 3,5,6 CFL23/27/GU24/DIM Warm White Dimmable 10/50 2700 82 1600 10000 4.73” 2.36”
26 WATT
T3 GU24 46528 $ 1,3,4 CFL26/27/GU24 Warm White 10/50 2700 82 1750 10000 5.20” 2.13”
46531 $ 1,3,4 CFL26/35/GU24 White 10/50 3500 82 1750 10000 5.20” 2.13”
46529 $ 1,3,4 CFL26/41/GU24 Cool White 10/50 4100 82 1750 10000 5.20” 2.13”
46530 $ 1,3,4 CFL26/50/GU24 Natural White 10/50 5000 82 1750 10000 5.20” 2.13”
27 WATT
T3 Med. 109310 $ 3,4,5 CFL27/27 Warm White 10/50 2700 82 1900 10000 5.44” 2.44”
45255 $ 3,4,5 CFL27/35 White 10/50 3500 82 1850 10000 5.44” 2.44”
109312 $ 3,4,5 CFL27/41 Cool White 10/50 4100 82 1850 10000 5.44” 2.44”
109314 $ 3,4,5 CFL27/50 Natural White 10/50 5000 82 1750 10000 5.44” 2.44”
Self-Ballasted
®
Spiral
GU24
®
Spiral
Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
62
COMPACT FLUORESCENT LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Lumens Avg.
Life MOL MOD
®
CFL Bare Spiral continued
32 WATT
T3 Med. 109316 $ 4,5,8 CFL32/27 Warm White 10/50 2700 82 2250 8000 5.56” 2.76”
109318 $ 4,5,8 CFL32/41 Cool White 10/50 4100 82 2200 8000 5.56” 2.76”
109306 $ 4,5,8 CFL32/50 Natural White 10/50 5000 82 2200 8000 5.56” 2.76”
42 WATT
T3 Med. 109328 $ 4,5,8 CFL42/27 Warm White 6/24 2700 82 2900 12000 7.06” 2.83”
109336 $ 4,5,8 CFL42/41 Cool White 6/24 4100 82 2800 12000 7.06” 2.83”
109338 $ 4,5,8 CFL42/50 Natural White 6/24 5000 82 2800 12000 7.06” 2.83”
65 WATT
T5 Med. 45600 $ 4,5,7 CFL65/27 Warm White 1/6 2700 82 4300 10000 9.50” 3.54”
45604 $ 4,5,7 CFL65/50 Natural White 1/6 5000 82 4300 10000 9.50” 3.54”
85 WATT
T5 Med. 45606 $ 4,5,7 CFL85/27 Warm White 1/6 2700 82 5700 10000 10.00” 4.02”
45610 $ 4,5,7 CFL85/50 Natural White 1/6 5000 82 5700 10000 10.00” 4.02”
Mog. 45500 $ 4,5,7 CFL85/50/E39 Natural White 1/6 5000 82 5700 10000 10.50” 4.02”
105 WATT
T5 Med. 45618 $ 4,5,7 CFL105/50 Natural White 1/6 5000 82 7000 10000 10.75” 4.02”
45502 $ 4,5,7,9 CFL105/50/277V Natural White 277V 1/6 5000 82 7000 10000 10.75” 4.02”
Mog. 45614 $ 4,5,7 CFL105/50/E39 Natural White 1/6 5000 82 7000 10000 11.25” 4.02”
45504 $ 4,5,7,9 CFL105/50/E39/277V Natural White 277V 1/6 5000 82 7000 10000 11.25” 4.02”
150 WATT
T6 EX39 47000 $ 4,5,7 CFL150/50/EX39 Natural White 1/6 5000 82 8800 10000 13.03” 4.72”
180 WATT
T6 EX39 47001 $ 4,5,7 CFL180/50/EX39 Natural White 1/6 5000 82 11100 10000 14.33” 4.72”
Spiral
Self-Ballasted
T6 EX39
Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 63
COMPACT FLUORESCENT LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Lumens Avg.
Life MOL MOD
CFL Reector
11 WATT
PAR20 Med. 46005 $ 2,4,8 CFL11/27/PAR20 Warm White Flood 6/24 2700 82 380 10000 3.86” 2.48”
46006 $ 2,4,8 CFL11/35/PAR20 White Flood 6/24 3500 82 380 10000 3.86” 2.48”
46007 $ 2,4,8 CFL11/41/PAR20 Cool White Flood 6/24 4100 82 380 10000 3.86” 2.48”
46008 $ 2,4,8 CFL11/50/PAR20 Natural White Flood 6/24 5000 82 380 10000 3.86” 2.48”
R20 GU24 46542 $ 2,4,8 CFL11/27/R20/GU24 Warm White Flood 6/24 2700 82 340 10000 4.02” 2.50”
14 WATT
R20 Med. 46011 $ 4,5,8 CFL14/30/R20 Soft White Flood 6/24 3000 82 500 8000 4.94” 2.52”
46014 $ 4,5,8 CFL14/50/R20 Natural White Flood 6/24 5000 82 500 8000 4.94” 2.52”
15 WATT
PAR30 Med. 46550 $ 2,6,8 CFL15/27/PAR30/DIM Warm White Dimmable Flood 6/24 2700 82 700 10000 4.60” 3.74”
46001 $ 2,4,8 CFL15/27/PAR30 Warm White Flood 6/24 2700 82 750 10000 4.60” 3.74”
46002 $ 2,4,8 CFL15/35/PAR30 White Flood 6/24 3500 82 750 10000 4.60” 3.74”
46003 $ 2,4,8 CFL15/41/PAR30 Cool White Flood 6/24 4100 82 750 10000 4.60” 3.74”
46004 $ 2,4,8 CFL15/50/PAR30 Natural White Flood 6/24 5000 82 750 10000 4.60” 3.74”
R30 Med. 46328 $ 5,6,8 CFL15/27/R30/DIM Warm White Dimmable Flood 6/24 2700 82 680 8000 6.01” 3.74”
109056 X $ 1,4 CFL15/BLU/R30 Blue Flood 6/24 - 82 720 8000 5.10” 3.78”
109058 X $ 1,4 CFL15/GRN/R30 Green Flood 6/24 - 82 720 8000 5.10” 3.78”
109054 X $ 1,4 CFL15/PNK/R30 Pink Flood 6/24 - 82 720 8000 5.10” 3.78”
109062 X $ 1,4 CFL15/YEL/R30 Yellow Flood 6/24 - 82 720 8000 5.10” 3.78”
GU24 46538 $ 1,4,8 CFL15/27/R30/GU24 Warm White 6/24 2700 82 750 10000 4.76” 3.74”
16 WATT
R30 Med. 46101 $ 4,5,8 CFL16/30/R30/ES Soft White, Energy Saver 6/24 3000 82 750 10000 5.60” 3.78”
46104 $ 4,5,8 CFL16/41/R30 Cool White Flood 6/24 4100 82 750 10000 5.60” 3.78”
46105 $ 4,5,8 CFL16/50/R30 Natural White Flood 6/24 5000 82 750 10000 5.60” 3.78”
23 WATT
BR38 Med. 109216 $ 2,4,8 CFL23/30/BR38 Soft White Flood 6/24 3000 82 1300 10000 6.40” 4.72”
PAR38 Med. 46201 $ 2,4,8 CFL23/27/PAR38 Warm White Flood 6/24 2700 82 1100 10000 5.06” 4.76”
46202 $ 2,4,8 CFL23/35/PAR38 White Flood 6/24 3500 82 1100 10000 5.06” 4.76”
46203 $ 2,4,8 CFL23/41/PAR38 Cool White Flood 6/24 4100 82 1100 10000 5.06” 4.76”
46204 $ 2,4,8 CFL23/50/PAR38 Natural White Flood 6/24 5000 82 1100 10000 5.06” 4.76”
R40 Med. 46329 $ 5,6,8 CFL23/27/R40/DIM Warm White Dimmable Flood 6/24 2700 82 1090 10000 6.97” 5.00”
46210 $ 4,5,8 CFL23/27/R40 Warm White Flood 6/24 2700 82 1090 10000 6.50” 5.00”
109286 $ 4,5,8 CFL23/30/R40 Soft White Flood 6/24 3000 82 1090 10000 6.50” 5.00”
46206 $ 4,5,8 CFL23/50/R40 Natural White Flood 6/24 5000 82 1090 10000 6.50” 5.00”
46208 $ 4,5,8 CFL23/PB/R40 Pool Bright Flood 6/24 6500 82 1000* 10000 6.50” 5.00”
®
®
R30
R40BR38PAR38
Self-Ballasted
®
PAR20
®
PAR30
®
R20
*Scotopic Lumens
Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
64
COMPACT FLUORESCENT LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Lumens Avg.
Life MOL MOD
®
CFL Decorative
5 WATT
A16 Med. 45730 X $ 1,3,4 CFL5/27/A16 Warm White 10/50 2700 82 250 8000 4.07” 2.13”
45732 X $ 1,3,4 CFL5/41/A16 Cool White 10/50 4100 82 250 8000 4.07” 2.13”
B13 Med. 45761 X $ 1,4,8 CFL5/30/B13 Soft White 10/50 3000 82 200 8000 4.57” 1.57”
Cand. 45762 X $ 1,4,8 CFL5/30/B13/E12 Soft White 10/50 3000 82 200 8000 3.86” 1.57”
9 WATT
A16 Med. 45734 $ 1,3,4 CFL9/27/A16 Warm White 10/50 2700 82 470 8000 4.50” 2.20”
B13 Med. 45763 $ 1,4,8 CFL9/30/B13 Soft White 10/50 3000 82 470 8000 4.92” 1.61”
Cand. 45764 $ 1,4,8 CFL9/30/B13/E12 Soft White 10/50 3000 82 470 8000 4.43” 1.61”
G25 Med. 45703 $ 1,3,4 CFL9/27/G25/ES Warm White 6/24 2700 82 500 10000 4.33” 3.11”
45705 $ 1,3,4 CFL9/50/G25 Natural White 6/24 5000 82 500 10000 4.33” 3.11”
14 WATT
A19 Med. 45738 $ 1,3,4 CFL14/27/A19 Warm White 10/50 2700 82 800 10000 4.63” 2.28”
45739 $ 1,3,4 CFL14/35/A19 White 10/50 3500 82 800 10000 4.63” 2.28”
45740 $ 1,3,4 CFL14/41/A19 Cool White 10/50 4100 82 800 10000 4.63” 2.28”
45741 $ 1,3,4 CFL14/50/A19 Natural White 10/50 5000 82 800 10000 4.63” 2.28”
T20 Med. 45755 X $ 4,5,8 CFL14/27/T20 Warm White 6/24 2700 82 800 8000 5.44” 2.48”
45758 $ 4,5,8 CFL14/50/T20 Natural White 6/24 5000 82 800 8000 5.44” 2.48”
15 WATT
A19 GU24 46540 X $ 4,5,8 CFL15/27/A19/GU24 Warm White 6/24 2700 82 800 10000 4.82” 2.64”
G25 GU24 46536 X $ 1,4,8 CFL15/27/G25/GU24 Warm White 6/24 2700 82 750 10000 4.80” 3.31”
G28 Med. 45713 $ 1,3,4 CFL15/27/G28 Warm White 6/24 2700 82 850 10000 4.73” 3.73”
45717 $ 1,3,4 CFL15/50/G28 Natural White 6/24 5000 82 850 10000 4.73” 3.73”
16 WATT
G30 Med. 45725 $ 4,5,8 CFL16/27/G30 Warm White 6/24 2700 82 900 10000 5.07” 3.70”
46533 $ 4,5,8 CFL16/50/G30 Natural White 6/24 5000 82 900 10000 5.07” 3.70”
20 WATT
A20 Med. 45743 $ 1,4,8 CFL20/27/A20 Warm White 6/24 2700 82 1100 8000 5.56” 2.80”
®
®
A16
A19
A20 T20
G25
G28
G30
Self-Ballasted
®
B13
Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 65
COMPACT FLUORESCENT LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Lumens Avg.
Life MOL MOD
Single Tube 2-Pin Eco-Shield®
5 WATT
T4 G23 109100 $ 10,11 PL5S/27/ECO Warm White 1/50 2700 82 250 12000 4.25” -
109102 $ 10,11 PL5S/41/ECO Cool White 1/50 4100 82 250 12000 4.25” -
7 WATT
T4 G23 109106 $ 11 PL7S/27/ECO Warm White 1/50 2700 82 400 12000 5.43” -
109107 $ 11 PL7S/35/ECO White 1/50 3500 82 400 12000 5.43” -
109108 $ 11 PL7S/41/ECO Cool White 1/50 4100 82 400 12000 5.43” -
9 WATT
T4 G23 109112 $ 11 PL9S/27/ECO Warm White 1/50 2700 82 600 12000 6.61” -
109144 $ 11 PL9S/35/ECO White 1/50 3500 82 600 12000 6.61” -
109116 $ 11 PL9S/41/ECO Cool White 1/50 4100 82 600 12000 6.61” -
109118 $ 11 PL9S/50/ECO Natural White 1/50 5000 82 600 12000 6.61” -
13 WATT
T4 GX23 109126 $ 11 PL13S/27/ECO Warm White 1/50 2700 82 825 12000 7.20” -
109128 $ 11 PL13S/35/ECO White 1/50 3500 82 825 12000 7.20” -
109130 $ 11 PL13S/41/ECO Cool White 1/50 4100 82 825 12000 7.20” -
109132 $ 11 PL13S/50/ECO Natural White 1/50 5000 82 825 12000 7.20” -
Single Tube 4-Pin Eco-Shield®
13 WATT
T4 2GX7 109134 $ 12,13 PL13S/E/27/ECO Warm White 1/50 2700 82 825 12000 6.30” -
109136 $ 12,13 PL13S/E/35/ECO White 1/50 3500 82 825 12000 6.30” -
109138 $ 12,13 PL13S/E/41/ECO Cool White 1/50 4100 82 825 12000 6.30” -
109140 $ 12,13 PL13S/E/50/ECO Natural White 1/50 5000 82 825 12000 6.30” -
Double Tube 2-Pin Eco-Shield®
9 WATT
T4 G23-2 109110 $ 11 PL9D/27/ECO Warm White 1/50 2700 82 525 12000 4.25” -
109120 $ 11 PL9D/41/ECO Cool White 1/50 4100 82 525 12000 4.25” -
13 WATT
T4 GX23-2 109146 $ 11 PL13D/27/ECO Warm White 1/50 2700 82 900 12000 4.65” -
109148 $ 11 PL13D/35/ECO White 1/50 3500 82 900 12000 4.65” -
109150 $ 11 PL13D/41/ECO Cool White 1/50 4100 82 900 12000 4.65” -
109149 $ 11 PL13D/50/ECO Natural White 1/50 5000 82 900 12000 4.65” -
18 WATT
T4 G24d-2 109152 $ 11 PL18D/27/ECO Warm White 1/50 2700 82 1200 12000 6.02” -
109154 $ 11 PL18D/35/ECO White 1/50 3500 82 1200 12000 6.02” -
109156 $ 11 PL18D/41/ECO Cool White 1/50 4100 82 1200 12000 6.02” -
109159 X $ 11 PL18D/50/ECO Natural White 1/50 5000 82 1200 12000 6.02” -
Single Tube
4-Pin
Single Tube
2-Pin
Double Tube
2-Pin
Plug-In
Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
66
COMPACT FLUORESCENT LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Lumens Avg.
Life MOL MOD
Double Tube 2-Pin continued
22 WATT
T5 GX32d-2 109862 $ 11 PL22D/28 Warm White 15mm Cluster 1/50 2800 82 1200 10000 6.15” -
109864 $ 11 PL22D/50 Natural White 15mm Cluster 1/50 5000 82 1200 10000 6.15” -
26 WATT
T5 G24d-3 109158 $ 11 PL26D/27/ECO Warm White 1/50 2700 82 1800 12000 6.77” -
109160 $ 11 PL26D/35/ECO White 1/50 3500 82 1800 12000 6.77” -
109162 $ 11 PL26D/41/ECO Cool White 1/50 4100 82 1800 12000 6.77” -
109163 $ 11 PL26D/50/ECO Natural White 1/50 5000 82 1800 12000 6.77” -
28 WATT
T5 GX32d-3 109870 $ 11 PL28D/28 Warm White 15mm Cluster 1/50 2800 82 1800 12000 6.60” -
109868 $ 11 PL28D/50 Natural White 15mm Cluster 1/50 5000 82 1800 12000 6.60” -
Double Tube 4-Pin Electronic Eco-Shield®
13 WATT
T4 G24q-1 109037 $ 12,13 PL13D/E/27/ECO Warm White 1/50 2700 82 900 15000 5.16” -
109035 $ 12,13 PL13D/E/30/ECO Soft White 1/50 3000 82 900 15000 5.16” -
109038 $ 12,13 PL13D/E/35/ECO White 1/50 3500 82 900 15000 5.16” -
109039 $ 12,13 PL13D/E/41/ECO Cool White 1/50 4100 82 900 15000 5.16” -
109122 $ 12,13 PL13D/E/50/ECO Natural White 1/50 5000 82 900 15000 5.16” -
18 WATT
T4 G24q-2 109010 $ 12,13 PL18D/E/27/ECO Warm White 1/50 2700 82 1200 15000 5.75” -
109012 $ 12,13 PL18D/E/35/ECO White 1/50 3500 82 1200 15000 5.75” -
109013 $ 12,13 PL18D/E/41/ECO Cool White 1/50 4100 82 1200 15000 5.75” -
109074 $ 12,13 PL18D/E/50/ECO Natural White 1/50 5000 82 1200 15000 5.75” -
26 WATT
T4 G24q-3 109090 $ 12,13 PL26D/E/27/ECO Warm White 1/50 2700 82 1800 15000 6.57” -
109092 $ 12,13 PL26D/E/35/ECO White 1/50 3500 82 1800 15000 6.57” -
109094 $ 12,13 PL26D/E/41/ECO Cool White 1/50 4100 82 1800 15000 6.57” -
109096 $ 12,13 PL26D/E/50/ECO Natural White 1/50 5000 82 1800 15000 6.57” -
Triple Tube 4-Pin Electronic Eco-Shield®
18 WATT
T4 GX24q-2 44800 $ 12,13 PL18T/E/27/ECO Warm White 1/50 2700 82 1200 15000 4.57” -
44801 $ 12,13 PL18T/E/35/ECO White 1/50 3500 82 1200 15000 4.57” -
44803 $ 12,13 PL18T/E/41/ECO Cool White 1/50 4100 82 1200 15000 4.57” -
44804 X $ 12,13 PL18T/E/50/ECO Natural White 1/50 5000 82 1200 15000 4.57” -
Double Tube
2-Pin/4-Pin
Triple Tube
4-Pin
Plug-In
Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 67
COMPACT FLUORESCENT LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Lumens Avg.
Life MOL MOD
Triple Tube 4-Pin Electronic Eco-Shield® continued
26 WATT
T4 GX24q-3 109020 $ 12,13 PL26T/E/27/ECO Warm White 1/50 2700 82 1800 15000 5.28” -
109022 $ 12,13 PL26T/E/35/ECO White 1/50 3500 82 1800 15000 5.28” -
109024 $ 12,13 PL26T/E/41/ECO Cool White 1/50 4100 82 1800 15000 5.28” -
109076 $ 12,13 PL26T/E/50/ECO Natural White 1/50 5000 82 1800 15000 5.28” -
32 WATT
T4 GX24q-3 109026 $ 12,13 PL32T/E/27/ECO Warm White 1/50 2700 82 2400 15000 5.79” -
109028 $ 12,13 PL32T/E/35/ECO White 1/50 3500 82 2400 15000 5.79” -
109030 $ 12,13 PL32T/E/41/ECO Cool White 1/50 4100 82 2400 15000 5.79” -
109070 $ 12,13 PL32T/E/50/ECO Natural White 1/50 5000 82 2400 15000 5.79” -
42 WATT
T4 GX24q-4 109032 $ 12,13 PL42T/E/27/ECO Warm White 1/50 2700 82 3200 15000 6.61” -
109034 $ 12,13 PL42T/E/35/ECO White 1/50 3500 82 3200 15000 6.61” -
109036 $ 12,13 PL42T/E/41/ECO Cool White 1/50 4100 82 3200 15000 6.61” -
109072 $ 12,13 PL42T/E/50/ECO Natural White 1/50 5000 82 3200 15000 6.61” -
57 WATT
T4 GX24q-5 44806 X $ 12,13 PL57T/E/27/ECO Warm White 1/50 2700 82 4200 12000 7.57” -
44807 $ 12,13 PL57T/E/41/ECO Cool White 1/50 4100 82 4200 12000 7.57” -
44808 $ 12,13 PL57T/E/50/ECO Natural White 1/50 5000 82 4200 12000 7.57” -
Triple Tube
4-Pin
Plug-In
Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
68
COMPACT FLUORESCENT LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Lumens Avg.
Life MOL MOD
High Lumen Long 4-Pin
18 WATT
T5 2G11 109700 $ 13 PLL18/835/ECO White 10/40 3500 82 1250 12000 8.94” -
109702 $ 13 PLL18/841/ECO Cool White 10/40 4100 82 1250 12000 8.94” -
24 WATT
T5 2G11 109704 $ 13 PLL24/835/ECO White 10/40 3500 82 1800 12000 12.70” -
109706 $ 13 PLL24/841/ECO Cool White 10/40 4100 82 1800 12000 12.70” -
36 WATT
T5 2G11 109708 $ 13 PLL36/835/ECO White 10/40 3500 82 2800 12000 16.45” -
109710 $ 13 PLL36/841/ECO Cool White 10/40 4100 82 2800 12000 16.45” -
40 WATT
T5 2G11 109712 $ 13 PLL40/830/RS/ECO Soft White 10/40 3000 82 3150 20000 22.50” -
109714 $ 13 PLL40/835/RS/ECO White 10/40 3500 82 3150 20000 22.50” -
109716 $ 13 PLL40/841/RS/ECO Cool White 10/40 4100 82 3150 20000 22.50” -
44900 $ 13 PLL40/850/RS/ECO Natural White 10/40 5000 82 3150 20000 22.50” -
55 WATT
T5 2G11 109718 $ 13 PLL55/835/ECO White 10/40 3500 82 4700 12000 21.20” -
109720 $ 13 PLL55/841/ECO Cool White 10/40 4100 82 4700 12000 21.20” -
Flat Quad 4-Pin Electronic
27 WATT
T5 GX10q-2 109238 $ 13 FML27/NDL Natural White 1/50 5000 82 1700 10000 5.90” 3.23”
Flat
Quad PLL
Plug-In
Compact Fluorescent lamp symbols, footnotes and abbreviations are located on pages 73-74.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 69
COMPACT FLUORESCENT LAMPS
Single Tube
2-Pin
Single Tube
4-Pin
Double Tube
2-Pin/4-Pin
Triple Tube
4-Pin
Flat Quad
4-Pin
PLL
4-Pin
®
R30/R40 A-Shape
®
Spiral
GU24
Plug-In R40
GX23-2GX23G23 G24q-1 G24q-2 G24q-3 G24d-2
GX24q-3 GX24q-4 GX24q-5 GX24d-3 2G11 2GX7 Medium
E26/27
E12
Double
15mm
R20
®
BR38
G
Globe
®
B13
Torpedo
®
Spiral
®
T20
Tubular
®
®
PAR20 PAR38
®
PAR30
®
GU24
Bulb and Base Identication Guide
Bulb Shapes
Base Types
TS EX39
EX39
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
70
Cross Reference Guide
COMPACT FLUORESCENT LAMPS
HALCO G.E. PHILIPS OSRAM/SYLVANIA
Single Tube 2-Pin
PL5S/27/ECO F5BX/827/ECO PL-S 5W/827/2P/ALTO CF5DS/827
PL5S/41/ECO F5BX/841/ECO PL-S 5W/841/2P/ALTO CF5DS/841
PL7S/27/ECO F7BX/827/ECO PL-S 7W/827/2P/ALTO CF7DS/827
PL7S/35/ECO F7BX/835/ECO PL-S 7W/835/2P/ALTO CF7DS/835
PL7S/41/ECO F7BX/841/ECO PL-S 7W/841/2P/ALTO CF7DS/841
PL9S/27/ECO F9BX/827/ECO PL-S 9W/827/2P/ALTO CF9DS/827
PL9S/35/ECO F9BX/835/ECO PL-S 9W/835/2P/ALTO CF9DS/835
PL9S/41/ECO F9BX/841/ECO PL-S 9W/841/2P/ALTO CF9DS/841
PL9S/50/ECO -PL-S 9W/850/2P/ALTO CF9DS/850
PL13S/27/ECO F13BX/827/ECO PL-S 13W/827/2P/ALTO CF13DS/827
PL13S/35/ECO F13BX/835/ECO PL-S 13W/835/2P/ALTO CF13DS/835
PL13S/41/ECO F13BX/841/ECO PL-S 13W/841/2P/ALTO CF13DS/841
PL13S/50/ECO F13BX/850/ECO PL-S 13W/850/2P/ALTO CF13DS/850
Double Tube 2-Pin
PL9D/27/ECO F9DBX23/827/ECO -CF9DD/827
PL9D/41/ECO F9DBX23/841/ECO -CF9DD/841
PL13D/27/ECO F13DBX23/827/ECO PL-C 13W/827/USA/ALTO CF13DD/827
PL13D/35/ECO F13DBX23/835/ECO PL-C 13W/835/USA/ALTO CF13DD/835
PL13D/41/ECO F13DBX23/841/ECO PL-C 13W/841/USA/ALTO CF13DD/841
PL13D/50/ECO ---
PL18D/27/ECO F18DBX/827/ECO PL-C 18W/827/ALTO CF18DD/827
PL18D/35/ECO F18DBX/835/ECO PL-C 18W/835/ALTO CF18DD/835
PL18D/41/ECO F18DBX/841/ECO PL-C 18W/841/ALTO CF18DD/841
PL18D/50/ECO ---
PL26D/27/ECO F26DBX/827/ECO PL-C 26W/827/ALTO CF26DD/827
PL26D/35/ECO F26DBX/835/ECO PL-C 26W/835/ALTO CF26DD/835
PL26D/41/ECO F26DBX/841/ECO PL-C 26W/841/ALTO CF26DD/841
PL26D/50/ECO ---
PL22D/28 -PL-C 15MM/22W/827 -
PL22D/50 ---
PL28D/28 -PL-C 15MM/28W/827 -
PL28D/50 ---
Single Tube 4-Pin Electronic
PL13S/E/27/ECO --CF13DS/E/827
PL13S/E/35/ECO ---
PL13S/E/41/ECO --CF13DS/E/841
PL13S/E/50/ECO ---
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 71
Cross Reference Guide
COMPACT FLUORESCENT LAMPS
HALCO G.E. PHILIPS OSRAM/SYLVANIA
Double Tube 4-Pin Electronic
PL13D/E/27/ECO F13DBX/827/ECO4P PL-C 13W/827/4P/ALTO CF13DD/E/827
PL13D/E/30/ECO F13DBX/830/ECO4P PL-C 13W/830/4P/ALTO CF13DD/E/830
PL13D/E/35/ECO F13DBX/835/ECO4P PL-C 13W/835/4P/ALTO CF13DD/E/835
PL13D/E/41/ECO F13DBX/841/ECO4P PL-C 13W/841/4P/ALTO CF13DD/E/841
PL13D/E/50/ECO ---
PL18D/E/27/ECO F18DBX/827/ECO4P PL-C 18W/827/4P/ALTO CF18DD/E/827
PL18D/E/35/ECO F18DBX/835/ECO4P PL-C 18W/835/4P/ALTO CF18DD/E/835
PL18D/E/41/ECO F18DBX/841/ECO4P PL-C 18W/841/4P/ALTO CF18DD/E/841
PL18D/E/50/ECO ---
PL26D/E/27/ECO F26DBX/827/ECO4P PL-C 26W/827/4P/ALTO CF26DD/E/827
PL26D/E/35/ECO F26DBX/835/ECO4P PL-C 26W/835/4P/ALTO CF26DD/E/835
PL26D/E/41/ECO F26DBX/841/ECO4P PL-C 26W/841/4P/ALTO CF26DD/E/841
PL26D/E/50/ECO ---
Triple Tube 4-Pin Electronic
PL18T/E/27/ECO F18TBX/827/A/ECO PL-T 18W/827/4P/ALTO CF18DT/E/IN/827
PL18T/E/35/ECO F18TBX/835/A/ECO PL-T 18W/835/4P/ALTO CF18DT/E/IN/835
PL18T/E/41/ECO F18TBX/841/A/ECO PL-T 18W/841/4P/ALTO CF18DT/E/IN/841
PL18T/E/50/ECO ---
PL26T/E/27/ECO F26TBX/827/A/ECO PL-T 26W/827/4P/ALTO CF26DT/E/IN/827
PL26T/E/35/ECO F26TBX/835/A/ECO PL-T 26W/835/4P/ALTO CF26DT/E/IN/835
PL26T/E/41/ECO F26TBX/841/A/ECO FL-T 26W/841/4P/ALTO CF26DT/E/IN/841
PL26T/E/50/ECO ---
PL32T/E/27/ECO F32TBX/827/A/ECO PL-T 32W/827/4P/ALTO CF32DT/E/IN/827
PL32T/E/35/ECO F32TBX/835/A/ECO PL-T 32W/835/4P/ALTO CF32DT/E/IN/835
PL32T/E/41/ECO F32TBX/841/A/ECO PL-T 32W/841/4P/ALTO CF32DT/E/IN/841
PL32T/E/50/ECO ---
PL42T/E/27/ECO F42TBX/827/A/ECO PL-T 42W/827/4P/ALTO CF42DT/E/IN/827
PL42T/E/35/ECO F42TBX/835/A/ECO PL-T 42W/835/4P/ALTO CF42DT/E/IN/835
PL42T/E/41/ECO F42TBX/841/A/ECO PL-T 42W/841/4P/ALTO CF42DT/E/IN/841
PL42T/E/50/ECO ---
PL57T/E/27/ECO F57QBX/827/A/ECO -CF57DT/E/IN/827
PL57T/E/41/ECO F57QBX/841/A/ECO PL-T 57W/841/4P/A CF57DT/E/IN/841
PL57T/E/50/ECO F57QBX/850/A/ECO -CF57DT/E/IN/850
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
72
Cross Reference Guide
COMPACT FLUORESCENT LAMPS
HALCO G.E. PHILIPS OSRAM/SYLVANIA
High Lumen Long 4-Pin
PLL18/835/ECO F18BX/SPX35 PL-L 18W/835/4P FT18DL/835/RS
PLL18/841/ECO F18BX/SPX41 PL-L 18W/841/4P FT18DL/841/RS
PLL24/835/ECO F27BX/SPX35/RS PL-L 24W/835/4P FT24DL/835
PLL24/841/ECO F27BX/SPX41/RS PL-L 24W/841/4P FT24DL/841
PLL36/835/ECO F39BX/SPX35/RS PL-L 36W/835/4P FT36DL/835
PLL36/841/ECO F39BX/SPX41/RS PL-L 36W/841/4P FT36DL/841
PLL40/830/RS/ECO F40/30BX/SPX30 PL-L 40W/830/4P/RS/IS FT40DL/830/RS
PLL40/835/RS/ECO F40/30BX/SPX35 PL-L 40W/835/4P/RS/IS FT40DL/835/RS
PLL40/841/RS/ECO F40/30BX/SPX41 PL-L 40W/841/4P/RS/IS FT40DL/841/RS
PLL40/850/RS/ECO F40/30BX/SPX50 -FT40DL/850/RS
PLL55/835/ECO F55BX/835 PL-L 50W/835/4P/RS FT55DL/835
PLL55/841/ECO F55BX/840 PL-L 50W/841/4P/RS FT55DL/841
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 73
COMPACT FLUORESCENT LAMPS
Symbols, Footnotes and Abbreviations
SYMBOLS
$Energy saving product.
ProLume® Eco-Shield® Low-Mercury Fluorescent lamps pass the Federal TCLP for hazardous wastes.
New product introduced within the past year.
XProduct will be discontinued when inventory is depleted.
FOOTNOTES
1UL approved for damp location in base-up position only. All other base positions must be in a dry
environment or in a weatherproof xture.
2UL approved for wet location in base-up position only. All other base positions must be in a dry
environment or in a weatherproof xture.
3UL approved for totally enclosed xtures with a max ballast case temperature of 90°C for GU24 base,
75°C for medium base lamps.
4Not intended for use with emergency exit xtures, dimmers, timing devices, photo sensors or
occupancy sensors.
5Do not use where lamp is exposed to moisture.
6For use on analog dimmers only - may not be compatible with all dimmers.
7Do not use in totally enclosed xtures or in recessed xtures.
8Do not use in totally enclosed xtures or insulated contact air tight (ICAT) rated xtures.
9Use only on 277 Volts, 60-hertz frequency.
10 PL 5 watt lamps should not be used in socket or adapters rated for 7 or 9 watt lamps.
11 Total wattage consumption for adapter systems is higher than lamp wattage due to ballast losses.
Total system wattage equals lamp wattage plus 2 ballast watts.
12 This 4-Pin Electronic lamp has an internal end-of-life (EOL) mechanism that shuts the lamp down
to prevent abnormal end-of-life failure.
13 Operate this lamp on a high-frequency Compact Fluorescent ballast with an end-of-life shut
down circuit.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
COMPACT FLUORESCENT LAMPS
74
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
/27 Sufx used to indicate color temperature of 2700K.
/30 Sufx used to indicate color temperature of 3000K.
/35 Sufx used to indicate color temperature of 3500K.
/3WAY Sufx used to indicate 3-Way lamps.
/41 Sufx used to indicate color temperature of 4100K.
/4PK Sufx used to indicate a package of (4) Compact Fluorescent lamps.
/50 Sufx used to indicate color temperature of 5000K.
/65 Sufx used to indicate color temperature of 6500K.
BLB Code abbreviation for Blacklight-Blue lamps.
CFL Code abbreviation for ProLume® Self-Ballasted Compact Fluorescent lamps.
BLU Code abbreviation for Blue lamps.
/CS Sufx used to indicate CoverShield® safety coated lamps.
DCode abbreviation for Double Tube lamps.
/DIM Sufx used to indicate Dimmable lamps.
/E Sufx used to indicate Electronic 4-Pin Plug-In lamps.
/ECO Sufx used to indicate Eco-Shield® TCLP compliant lamps.
GRN Code abbreviation for Green lamps.
/PB Sufx used to indicate Pool Bright pool lamps color temperature of 6450K.
PL Code abbreviation for ProLume® Plug-In Compact Fluorescent lamps.
PLL Code abbreviation for ProLume® Plug-In High Lumen long lamps.
PNK Code abbreviation for Pink lamps.
SCode abbreviation for Single Tube Plug-In lamps.
SP Code abbreviation for Spiral Tube Plug-In lamps.
TCode abbreviation for Triple Tube Plug-In lamps.
YEL Code abbreviation for Yellow lamps.
TOC
®
LINEAR FLUORESCENT LAMPS
CONTENTS
How to Read a Table
T5, T8, T12 Preheat Lamps
T5 Programmed Start Lamps
T8 Rapid Start Lamps
T12 Rapid Start Lamps
T6, T12 Slimline Instant Start Lamps
T8, T12 High Output Lamps
T8, T12 Very High Output Lamps
T8, T12 U-Bend Lamps
T5, T9 Circline Lamps
T8, T12 Appliance Lamps
T5, T8, T12 Blacklight & Blacklight-Blue
Base and Bulb Identication
Cross Reference Guide
Symbols, Footnotes and Abbreviations
78
79
79
80
82
82
83
83
83
84
84
84
85
86
90
main
TOC
HOW TO READ A LINEAR FLUORESCENT
LAMP TABLE
BULB
Designations indicate shape and size.
Illustrations can be found on page 85.
and at the top of each page.
PACKAGE QUANTITY
Indicates minimum sell quantity
and smallest shipping carton.
PRODUCT CODE
Abbreviated product description
can also be used for ordering.
A key to abbreviations can be
found on page 91.
Preheat - Medium Bi-Pin
T8 14 109370 1 F14T8CW Cool White 25 4100 62 650 585 8000 14”
15 9202 1 F15T8CW Cool White 30 4100 62 770 690 8000 17”
15 109212 1 F15T8DL Daylight 30 6500 74 770 690 8000 17”
15 109208 1 F15T8WW Warm White 30 3000 53 845 750 8000 17”
30 9225 1 F30T8CW Cool White 30 4100 62 2100 1900 9000 35”
Bulb Watts Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Initial
Lumens
Mean
Lumens
Avg.
Life
Nom.
Length
COLOR
TEMP.
A term used to
describe the color
of a light source
and is expressed
in degrees
“Kelvin”(K).
INITIAL
LUMENS
The lamp’s
average light
output after
the initial
100 hours of
operation.
MEAN
LUMENS
The lamp’s average
light output at 40%
of rated life.
NOM.
LENGTH
A measurement for
uorescent lamp
length based on the
length of the lamp
plus an allowance
for the luminaire’s
lamp holders.
CRI
An international
scale from 0 to 100 that
indicates the relative color
rendering value of a light
source. The color rendering
index expresses the degree
to which colors will look
“natural” under a given light
source.
PRODUCT
NUMBER
Use this number when
placing an order.
FOOTNOTES &
SYMBOLS
Related footnotes can
be found on page 90.
DESCRIPTION
Bulb nish and other
important information.
AVERAGE
LIFE
Average rated
life expressed
in hours.
WATTS
Indicates the
power consumed
by the lamp during
operation.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 79
LINEAR FLUORESCENT LAMPS
Bulb Watts Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Initial
Lumens
Mean
Lumens
Avg.
Life
Nom.
Length
Preheat - Miniature Bi-Pin
T5 4 9213 1,7 F4T5CW Cool White 10/1000 4100 65 130 117 6000 6”
6 9200 1,7 F6T5CW Cool White 10/500 4100 65 240 216 6000 9”
8 9206 1,7 F8T5BLB Blacklight-Blue 10/500 - - - - 6000 12”
8 9201 1,7 F8T5CW Cool White 10/500 4100 65 350 315 6000 12”
8 9215 1,7 F8T5DL Daylight 10/500 6500 75 350 279 6000 12”
8 9210 1,7 F8T5WW Warm White 10/500 3000 53 400 380 6000 12”
13 9231 1,7 F13T5CW Cool White 10/200 4100 65 740 666 6000 21”
13 9232 1,7 F13T5WW Warm White 10/200 3000 53 870 825 6000 21”
Preheat - Medium Bi-Pin
T8 14 109370 1 F14T8CW Cool White 25 4100 62 650 585 8000 14”
15 9202 1 F15T8CW Cool White 30 4100 62 770 690 8000 17”
15 109212 1 F15T8DL Daylight 30 6500 74 770 690 8000 17”
15 109208 1 F15T8WW Warm White 30 3000 53 845 750 8000 17”
30 9225 1 F30T8CW Cool White 30 4100 62 2100 1900 9000 35”
T12 14 9228 1 F14T12CW Cool White 30 4100 62 480 432 9000 14”
15 9212 1 F15T12CW Cool White 30 4100 62 650 570 9000 17”
20 9203 1 F20T12CW Cool White 30 4100 62 1150 1000 8000 24”
20 9235 1 F20T12DL Daylight 30 6500 74 1100 960 8000 24”
20 9227 1 F20T12WW Warm White 30 3000 52 1200 1080 8000 24”
T-5 Programmed Start - Miniature Bi-Pin Eco-Shield®
T5 14 30117 1,7 F14T5/830/ECO/IC 830 Phosphor 25 3000 86 1350 1270 24000 22”
14 30118 1,7 F14T5/835/ECO/IC 835 Phosphor 25 3500 86 1350 1270 24000 22”
14 30119 1,7 F14T5/841/ECO/IC 841 Phosphor 25 4100 86 1350 1270 24000 22”
21 30125 1,7 F21T5/830/ECO/IC 830 Phosphor 25 3000 86 2100 1990 24000 34”
21 30126 1,7 F21T5/835/ECO/IC 835 Phosphor 25 3500 86 2100 1990 24000 34”
21 30127 1,7 F21T5/841/ECO/IC 841 Phosphor 25 4100 86 2100 1990 24000 34”
24 30134 1,7 F24T5/835/HO/ECO/IC 835 Phosphor High Output 25 3500 86 2000 1900 20000 22”
24 30135 1,7 F24T5/841/HO/ECO/IC 841 Phosphor High Output 25 4100 86 2000 1900 20000 22”
28 35041 E 1,7 F28T5/830/ECO/IC 830 Phosphor 25 3000 86 2900 2750 24000 46”
28 35042 E 1,7 F28T5/835/ECO/IC 835 Phosphor 25 3500 86 2900 2750 24000 46”
28 35046 E X 1,7 F28T5/835/ECO/XL 835 Phosphor 25 3500 86 2800 2660 40000 46”
28 35043 E 1,7 F28T5/841/ECO/IC 841 Phosphor 25 4100 86 2900 2750 24000 46”
28 90016 E X 1,7 F28T5/841/ECO/IC/CS 841 Phosphor, CoverShield®25 4100 86 2900 2750 24000 46”
28 35044 E 1,7 F28T5/850/ECO/IC 850 Phosphor 25 5000 86 2900 2750 24000 46”
T12 Med.
Bi-Pin
T5
Miniature Bi-Pin
T8 Med.
Bi-Pin
E Means this lamp meets Federal Minimum Efciency standards.
Linear Fluorescent lamp symbols, footnotes and abbreviations are located on pages 90-91.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Bulb Watts Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Initial
Lumens
Mean
Lumens
Avg.
Life
Nom.
Length
80
LINEAR FLUORESCENT LAMPS
T-5 Programmed Start - Miniature Bi-Pin Eco-Shield® continued
T5 35 35049 1,7 F35T5/835/ECO/IC 835 Phosphor 25 3500 86 3650 3450 24000 58”
35 35050 1,7 F35T5/841/ECO/IC 841 Phosphor 25 4100 86 3650 3450 24000 58”
39 35060 X 1,7 F39T5/830/HO/ECO/IC 830 Phosphor High Output 25 3000 86 3500 3320 24000 34”
39 35061 1,7 F39T5/835/HO/ECO/IC 835 Phosphor High Output 25 3500 86 3500 3320 24000 34”
39 35062 1,7 F39T5/841/HO/ECO/IC 841 Phosphor High Output 25 4100 86 3500 3320 24000 34”
49 35085 E $ 1,7 F49T5/835/HO/ECO 835 Phosphor High Output,
Energy Saver 25 3500 86 4900 4700 24000 46”
49 35088 E $ 1,7 F49T5/841/HO/ECO 841 Phosphor High Output,
Energy Saver 25 4100 86 4900 4700 24000 46”
49 35089 E $ 1,7 F49T5/850/HO/ECO 850 Phosphor High Output,
Energy Saver 25 5000 86 4900 4700 24000 46”
54 35081 E 1,7 F54T5/830/HO/ECO/IC 830 Phosphor High Output 25 3000 86 5000 4850 24000 46”
54 35082 E 1,7 F54T5/835/HO/ECO/IC 835 Phosphor High Output 25 3500 86 5000 4850 24000 46”
54 90051 E 1,7 F54T5/835/HO/ECO/IC/CS 835 Phosphor High Output,
CoverShield®25 3500 86 5000 4850 24000 46”
54 35070 E X 1,7 F54T5/835/HO/ECO/XL 835 Phosphor High Output,
Extended Life 25 3500 86 5000 4790 40000 46”
54 105680 E 1,7 F54T5/841/HO/ECO 841 Phosphor High Output 25 4100 86 5000 4850 24000 46”
54 35083 E 1,7 F54T5/841/HO/ECO/IC 841 Phosphor High Output 25 4100 86 5000 4850 24000 46”
54 90052 E 1,7 F54T5/841/HO/ECO/IC/CS 841 Phosphor High Output,
CoverShield®25 4100 86 5000 4850 24000 46”
54 35071 E X 1,7 F54T5/841/HO/ECO/XL 841 Phosphor High Output,
Extended Life 25 4100 86 5000 4790 40000 46”
54 35084 E 1,7 F54T5/850/HO/ECO/IC 850 Phosphor High Output 25 5000 86 5000 4850 24000 46”
54 90053 E 1,7 F54T5/850/HO/ECO/IC/CS 850 Phosphor High Output,
CoverShield®25 5000 86 5000 4850 24000 46”
54 35072 E X 1,7 F54T5/850/HO/ECO/XL 850 Phosphor High Output,
Extended Life 25 5000 86 5000 4790 40000 46”
54 35086 E 1,7 F54T5/865/HO/ECO/IC 865 Phosphor High Output 25 6500 86 5000 4850 24000 46”
80 35087 1,7 F80T5/835/HO/ECO 835 Phosphor High Output 25 3500 86 7000 6650 24000 57.1”
80 35090 1,7 F80T5/841/HO/ECO 841 Phosphor High Output 25 4100 86 7000 6650 24000 57.1”
T- 8 Rapid Start - Medium Bi-Pin Eco-Shield®
T8 17 109320 1 F17T8/730/ECO 730 Phosphor 25 3000 78 1350 1280 24000 24”
17 109322 1 F17T8/735/ECO 735 Phosphor 25 3500 78 1350 1280 24000 24”
17 109324 1 F17T8/741/ECO 741 Phosphor 25 4100 78 1350 1280 24000 24”
17 109326 1 F17T8/750/ECO 750 Phosphor 25 5000 78 1350 1280 24000 24”
17 35170 1 F17T8/830/ECO 830 Phosphor 25 3000 86 1400 1330 24000 24”
17 109802 1 F17T8/835/ECO 835 Phosphor 25 3500 86 1400 1330 24000 24”
17 109804 1 F17T8/841/ECO 841 Phosphor 25 4100 86 1400 1330 24000 24”
17 35180 1 F17T8/850/ECO 850 Phosphor 25 5000 86 1400 1330 24000 24”
T5
Miniature Bi-Pin
T8 Med.
Bi-Pin
E Means this lamp meets Federal Minimum Efciency standards.
Linear Fluorescent lamp symbols, footnotes and abbreviations are located on pages 90-91.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 81
LINEAR FLUORESCENT LAMPS
Bulb Watts Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Initial
Lumens
Mean
Lumens
Avg.
Life
Nom.
Length
T-8 Rapid Start - Medium Bi-Pin continued
T8 25 109340 1 F25T8/730/ECO 730 Phosphor 25 3000 78 2150 2050 24000 36”
25 109342 1 F25T8/735/ECO 735 Phosphor 25 3500 78 2150 2050 24000 36”
25 109344 1 F25T8/741/ECO 741 Phosphor 25 4100 78 2150 2050 24000 36”
25 109346 1 F25T8/750/ECO 750 Phosphor 25 5000 78 2150 2050 24000 36”
25 109806 1 F25T8/830/ECO 830 Phosphor 25 3000 86 2250 2140 24000 36”
25 109808 1 F25T8/835/ECO 835 Phosphor 25 3500 86 2250 2140 24000 36”
25 109810 1 F25T8/841/ECO 841 Phosphor 25 4100 86 2250 2140 24000 36”
25 35162 E $ 1,8 F25T8ES/830/ECO 830 Phosphor, Energy Saver 25 3000 86 2500 2380 24000 48”
25 35172 E $ 1,8 F25T8ES/835/ECO 835 Phosphor, Energy Saver 25 3500 86 2500 2380 24000 48”
25 35173 E $ 1,8 F25T8ES/841/ECO 841 Phosphor, Energy Saver 25 4100 86 2500 2380 24000 48”
25 35174 E $ 1,8 F25T8ES/850/ECO 850 Phosphor, Energy Saver 25 5000 86 2500 2380 24000 48”
28 35175 E $ 1 F28T8/830/ECO 830 Phosphor 25 3000 86 2800 2660 24000 48”
28 109364 E $ 1 F28T8/835/ECO 835 Phosphor 25 3500 86 2800 2660 24000 48”
28 90081 E X $ 1 F28T8/835/ECO/IC/CS 835 Phosphor, CoverShield®25 3500 86 2800 2660 24000 48”
28 109366 E $ 1 F28T8/841/ECO 841 Phosphor 25 4100 86 2800 2660 24000 48”
28 109368 E $ 1 F28T8/850/ECO 850 Phosphor 25 5000 86 2800 2660 24000 48”
32 109412 E L,1 F32T8/730/ECO 730 Phosphor 25 3000 78 2850 2700 24000 48”
32 109414 E L,1 F32T8/735/ECO 735 Phosphor 25 3500 78 2850 2700 24000 48”
32 90084 E 1F32T8/735/ECO/CS 735 Phosphor, CoverShield®25 3500 78 2850 2700 24000 48”
32 109416 E L,1 F32T8/741/ECO 741 Phosphor 25 4100 78 2850 2700 24000 48”
32 90085 E 1F32T8/741/ECO/CS 741 Phosphor, CoverShield®25 4100 78 2850 2700 24000 48”
32 109418 E L,1 F32T8/750/ECO 750 Phosphor 25 5000 78 2850 2700 24000 48”
32 90089 E 1F32T8/750/ECO/CS 750 Phosphor, CoverShield®25 5000 78 2850 2700 24000 48”
32 30170 E L,1 F32T8/765/ECO 765 Phosphor 25 6500 78 2850 2700 24000 48”
32 109398 E 1F32T8/830/ECO 830 Phosphor 25 3000 86 3050 2900 24000 48”
32 109400 E 1F32T8/835/ECO 835 Phosphor 25 3500 86 3050 2900 24000 48”
32 35176 E 1F32T8/835/ECO/HL 835 Phosphor High Lumen 25 3500 86 3150 3000 24000 48”
32 90094 E 1F32T8/835/ECO/CS 835 Phosphor, CoverShield®25 3500 86 3050 2900 24000 48”
32 109402 E 1F32T8/841/ECO 841 Phosphor 25 4100 86 3050 2900 24000 48”
32 35177 E 1F32T8/841/ECO/HL 841 Phosphor High Lumen 25 4100 86 3150 3000 24000 48”
32 90095 E 1F32T8/841/ECO/CS 841 Phosphor, CoverShield®25 4100 86 3050 2900 24000 48”
32 109404 E 1F32T8/850/ECO 850 Phosphor 25 5000 86 3050 2900 24000 48”
32 35178 E 1F32T8/850/ECO/HL 850 Phosphor High Lumen 25 5000 86 3150 3000 24000 48”
32 90096 E 1F32T8/850/ECO/CS 850 Phosphor, CoverShield®25 5000 86 3050 2900 24000 48”
32 109428 E 1F32T8/865/ECO 865 Phosphor 25 6500 86 3050 2900 24000 48”
Eco-Shield®
T8 Med.
Bi-Pin
E Means this lamp meets Federal Minimum Efciency standards.
Linear Fluorescent lamp symbols, footnotes and abbreviations are located on pages 90-91.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Bulb Watts Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Initial
Lumens
Mean
Lumens
Avg.
Life
Nom.
Length
82
LINEAR FLUORESCENT LAMPS
T-8 Rapid Start - Medium Bi-Pin continued
T8 32 37200 1 F32T8BLB Blacklight-Blue 12 - - - - 20000 48”
40 30171 1F40T8/735/ECO 735 Phosphor 30 3500 78 3600 3450 24000 60”
40 30172 1F40T8/741/ECO 741 Phosphor 30 4100 78 3600 3450 24000 60”
58 35179 1F58T8/840 840 Phosphor 25 4000 86 5300 5000 24000 60”
70 39452 1 F70T8/840/M 840 Phosphor Major 25 4000 85 6000 5985 20000 70”
T-8 Rapid Start - Single Pin
T8 59 23411 E $ 1 F96T8/735/M 735 Phosphor Major 24 3500 75 5700 5130 15000 96”
59 23412 E $ 1 F96T8/741/M 741 Phosphor Major 24 4100 72 5700 5130 15000 96”
59 205773 E $ 1 F96T8/850/M 850 Phosphor Major 24 5000 80 5900 5428 15000 96”
T-12 Rapid Start - Medium Bi-Pin
T12 30 9204 1 F30T12CW Cool White 30 4100 62 2100 1830 8000 36”
30 9236 1 F30T12DL Daylight 30 6500 74 1900 1650 8000 36”
30 313742 1 F30T12WW Warm White Major 30 3000 53 2300 2000 18000 36”
34 24588 1 F34CWX/SS/M Cool White Deluxe Major 30 4100 87 1925 1656 20000 48”
40 423889 1 F40CWS/ECO/M Cool White Supreme Major 30 4100 89 2600 2250 20000 48”
40 109480 1 F40/350BL Blacklight 6 - - - - 20000 48”
40 109490 1 F40BLB Blacklight-Blue 6 - - - - 20000 48”
Slimline Instant Start - Single Pin
T6 25 24266 1 F42T6CW/M Cool White Major 24 4100 60 1750 1540 7500 42”
T12 39 363218 1 F48CW/M Cool White Low Mercury Major 15 4100 62 2950 2600 9000 48”
39 387019 1 F48DL/M Daylight Low Mercury Major 15 6500 79 2500 2375 9000 48”
50 26001 1 F60CW/M Cool White Major 30 4100 60 3700 3256 12000 60”
50 23076 1 F60DL/M Daylight Major 30 6500 76 3000 2640 12000 60”
50 355768 1 F64CW/M Cool White Major 30 4100 60 3900 3432 12000 64”
50 355776 1 F64DL/M Daylight Major 30 6500 76 3300 2904 12000 64”
56 369892 1 F72CW/M Cool White Low Mercury Major 15 4100 59 4450 3900 12000 72”
56 369850 1 F72DL/M Daylight Low Mercury Major 15 6500 79 3800 3350 12000 72”
70 13764 1 F84CW/M Cool White Major 15 4100 60 5300 4664 12000 84”
75 423194 1 F96CWS/ECO/M Cool White Supreme Major 15 4100 89 5000 4250 12000 96”
75 14067 E 1 F96/735/M 735 Phosphor Major 15 3500 70 6420 5906 12000 96”
Eco-Shield®
T12
Single Pin
T6
Single Pin
T8
Single Pin
T12 Med.
Bi-Pin
T8 Med.
Bi-Pin
E Means this lamp meets Federal Minimum Efciency standards.
Linear Fluorescent lamp symbols, footnotes and abbreviations are located on pages 90-91.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 83
LINEAR FLUORESCENT LAMPS
Bulb Watts Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Initial
Lumens
Mean
Lumens
Avg.
Life
Nom.
Length
High Output (800mA) - Recessed DC Base
T8 86 12537 E 1,4,5 F96T8/735HO/M 735 Phosphor High Output Major 24 3500 78 8000 7520 18000 96”
86 12538 E 1,4,5 F96T8/741HO/M 741 Phosphor High Output Major 24 4100 78 8000 7520 18000 96”
T12 35 262790 1,4,5 F24T12CWHO/M Cool White High Output Major 30 4100 60 1650 1337 9000 24”
35 262741 1,4,5 F24T12DLHO/M Daylight High Output Major 30 6500 76 1400 1134 9000 24”
42 226464 1,4,5 F30T12CWHO/M Cool White High Output Major 30 4100 60 2250 1825 9000 30”
45 262865 1,4,5 F36T12CWHO/M Cool White High Output Major 30 4100 60 2850 2309 9000 36”
45 262907 1,4,5 F36T12DLHO/M Daylight High Output Major 30 6500 76 2500 2025 9000 36”
55 10559 1,4,5 F42CWHO/M Cool White High Output Major 30 4100 60 3400 2754 9000 42”
55 10560 1,4,5 F42DLHO/M Daylight High Output Major 30 6500 76 3050 2471 9000 42”
60 369785 1,4,5 F48CWHO/M Cool White High Output
Low Mercury Major 15 4100 59 4050 3500 12000 48”
60 369843 1,4,5 F48DLHO/M Daylight High Output
Low Mercury Major 15 6500 73 3400 3000 12000 48”
75 251260 1,4,5 F60CWHO/M Cool White High Output Major 30 4100 60 5200 4212 12000 60”
75 25120 1,4,5 F60DLHO/M Daylight High Output Major 30 6500 76 4600 3826 12000 60”
85 366518 1,4,5 F72CWHO/M Cool White High Output
Low Mercury Major 15 4100 62 6350 5500 12000 72”
85 366534 1,4,5 F72DLHO/M Daylight High Output
Low Mercury Major 15 6500 79 5600 4850 12000 72”
100 13766 1,4,5 F84CWHO/M Cool White High Output Major 15 4100 62 7490 6800 12000 84”
100 13767 1,4,5 F84DLHO/M Daylight High Output Major 15 6500 76 6700 5427 12000 84”
110 381774 1,4,5,6 F96DLHOO/A Daylight High Output
Low Mercury Major 15 6500 79 7800 6800 12000 96”
Very High Output (1500mA) - Recessed DC Base
T12 110 25248 1,4,5 F48CWVHO/M Cool White Very High Output Major 24 4100 60 6200 4620 10000 48”
160 13760 1,4,5 F72CWVHO/M Cool White Very High Output Major 15 4100 60 10600 7420 10000 72”
215 342345 1,4,5 F96CWVHO/M Cool White Very High Output Major 15 4100 60 14000 9800 10000 96”
U-Bend Rapid Start - Medium Bi-Pin Base Eco-Shield®
T8 28 35307 E $,1,3 FB28/835/6/ECO/IC 835 Phosphor 6” 20 3500 86 2650 2450 24000 22.6”
28 35311 E $,1,3 FB28/841/6/ECO/IC 841 Phosphor 6” 20 4100 86 2650 2450 24000 22.6”
31 30301 E 1,3 FB31/830/ECO 830 Phosphor 1-5/8” 12 3000 86 2750 2600 24000 22.6”
31 30302 E 1,3 FB31/835/ECO 835 Phosphor 1-5/8” 12 3500 86 2750 2600 24000 22.6”
31 30303 E 1,3 FB31/841/ECO 841 Phosphor 1-5/8” 12 4100 86 2750 2600 24000 22.6”
31 30304 E 1,3 FB31/850/ECO 850 Phosphor 1-5/8” 12 5000 86 2750 2600 24000 22.6”
T12
Recessed DC
T8
Recessed DC
T8
U-Bend
E Means this lamp meets Federal Minimum Efciency standards.
Linear Fluorescent lamp symbols, footnotes and abbreviations are located on pages 90-91.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Bulb Watts Product
Number Footnotes Product
Code Description Pkg.
Qty.
Color
Temp. CRI Initial
Lumens
Mean
Lumens
Avg.
Life
Nom.
Length
84
LINEAR FLUORESCENT LAMPS
U-Bend Rapid Start - Medium Bi-Pin Base Eco-Shield® continued
T8 32 109500 E L,1,3 FB32/730/6/ECO 730 Phosphor 6” 20 3000 78 2750 2400 24000 22.6”
32 109502 E L,1,3 FB32/735/6/ECO 735 Phosphor 6” 20 3500 78 2750 2400 24000 22.6”
32 109504 E L,1,3 FB32/741/6/ECO 741 Phosphor 6” 20 4100 78 2750 2400 24000 22.6”
32 109506 E L,1,3 FB32/750/6/ECO 750 Phosphor 6” 20 5000 78 2750 2400 24000 22.6”
32 35313 E X 1,3 FB32/830/6/ECO/IC 830 Phosphor 6” 20 3000 86 2900 2750 24000 22.6”
32 109814 E 1,3 FB32/835/6/ECO 835 Phosphor 6” 20 3500 86 2900 2750 24000 22.6”
32 109816 E 1,3 FB32/841/6/ECO 841 Phosphor 6” 20 4100 86 2900 2750 24000 22.6”
32 109818 E 1,3 FB32/850/6/ECO 850 Phosphor 6” 20 5000 86 2900 2750 24000 22.6”
T12 40 219931 1,3 FB40DX/6/M Daylight 6” Major 12 6500 84 2250 2125 18000 22.5”
40 24004 1,3 FB40CWXU6 Cool White 6” Major 12 4100 87 2100 1806 18000 22.5”
Circline T5 Programmed Start - 2GX13 Base
T5 22 109080 2,7 FC22T5/835 835 Phosphor 20 3500 82 1900 1800 10000 9”
22 109082 2,7 FC22T5/841 841 Phosphor 20 4100 82 1900 1800 10000 9”
40 109084 2,7 FC40T5/835 835 Phosphor 20 3500 82 3350 3150 10000 12”
40 109086 2,7 FC40T5/841 841 Phosphor 20 4100 82 3350 3150 10000 12”
Circline T9 Rapid Start - G10q Base
T9 22 37501 1 FC8T9CW Cool White 12 4100 62 1150 1050 10000 8”
22 37503 1 FC8T9DL Daylight 12 6500 75 1150 1050 10000 8”
30 37504 1 FC9T9/830 830 Phosphor 12 3000 86 1800 1700 10000 9”
32 37507 1 FC12T9CW Cool White 12 4100 62 2100 2000 10000 12”
40 37510 1 FC16T9CW Cool White 12 4100 62 2900 2700 10000 16”
Appliance - Medium Bi-Pin Base
T8 18 109234 1 F18T8CW/K24 Cool White 24” 25 4100 62 1175 1025 7500 24”
18 23027 1 F18T8CW/K26 Cool White 26” Major 24 4100 62 1280 1080 7500 26”
18 23028 1 F18T8CW/K28 Cool White 28” Major 24 4100 62 1360 1130 7500 28”
18 23030 1 F18T8CW/K30 Cool White 30” Major 24 4100 62 1400 1200 7500 30”
T12 25 22527 1 F25T12CW/28 Cool White 28” Major 30 4100 62 1670 1450 7500 28”
25 22529 1 F25T12CW/33 Cool White 33” Major 30 4100 62 1850 1200 7500 33”
Blacklight & Blacklight-Blue
T5 8 9206 1 F8T5BLB Blacklight-Blue 10/500 - - - - 5000 12”
T8 32 37200 1 F32T8BLB Blacklight-Blue 12 - - - - 20000 48”
T12 40 109490 1 F40BLB Blacklight-Blue 6 - - - - 20000 48”
40 109480 1 F40/350BL Blacklight 6 - - - - 20000 48”
T9 Circline
T5 Circline U-Bend
T5
T12 Med.
Bi-Pin
T8 Med.
Bi-Pin
E Means this lamp meets Federal Minimum Efciency standards.
Linear Fluorescent lamp symbols, footnotes and abbreviations are located on pages 90-91.
TOC
85
Circline T5 T6 T8 T12 U-Bend
Miniature
Bi-Pin
Medium
Bi-Pin
Recessed DC Single Pin
Bulb and Base Identication Guide
Bulb Shapes
Base Types
LINEAR FLUORESCENT LAMPS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Cross Reference Guide
86
LINEAR FLUORESCENT LAMPS
HALCO G.E. PHILIPS OSRAM/SYLVANIA
Preheat Lamps
F18T8CW/K24 F24”T8CW/4 F18T8/CW/24 F18T8CW/K24
F18T8CW/K26 F26”T8CW/4 F16T8/CW/26 F18T8CW/K26
F18T8CW/K28 F28”T8CW/4 F17T8/CW/28 F18T8CW/K28
F18T8CW/K30 F30”T8CW/4 F18T8/CW/30/ALTO F18T8CW/K30
F25T12CW/28 F25T12/CW/28 - F25T12/CW/28
F25T12CW/33 F25T12/CW/33 F25T12/CW F25T12/CW/33
Ultra Efcient T-5
F14T5/830/ECO/IC F14W/T5/830/ECO F14T5/830/ALTO FP14/830/ECO
F14T5/835/ECO/IC F14W/T5/835/ECO F14T5/835/ALTO FP14/835/ECO
F14T5/841/ECO/IC F14W/T5/841/ECO F14T5/841/ALTO FP14/841/ECO
F21T5/830/ECO/IC F21W/T5/830/ECO F21T5/830/ALTO FP21/830/ECO
F21T5/835/ECO/IC F21W/T5/835/ECO F21T5/835/ALTO FP21/835/ECO
F21T5/841/ECO/IC F21W/T5/841/ECO F21T5/841/ALTO FP21/841/ECO
F28T5/830/ECO/IC F28W/T5/830/ECO F28T5/830/ALTO FP28/830/ECO
F28T5/835/ECO/IC F28W/T5/835/ECO F28T5/835/ALTO FP28/835/ECO
F28T5/841/ECO/IC F28W/T5/841/ECO F28T5/841/ALTO FP28/841/ECO
F28T5/850/ECO/IC F28W/T5/850/ECO - FP28/850/ECO
F28T5/835/ECO/XL - - -
F28T5/841/ECO/XL - - -
F35T5/835/ECO/IC F35W/T5/835/ECO F35T5/835/ALTO FP35/835/ECO
F35T5/841/ECO/IC F35W/T5/841/ECO F35T5/841/ALTO FP35/841/ECO
Ultra Efcient T-5 High Output
F24T5/835/HO/ECO/IC F24W/T5/835/ECO F24T5/835/HO/ALTO FP24/835/HO/ECO
F24T5/841/HO/ECO/IC F24W/T5/841/ECO F24T5/841/HO/ALTO FP24/841/HO/ECO
F39T5/830/HO/ECO/IC F39W/T5/830/ECO F39T5/830/HO/ALTO FP39/830/HO/ECO
F39T5/835/HO/ECO/IC F39W/T5/835/ECO F39T5/835/HO/ALTO FP39/835/HO/ECO
F39T5/841/HO/ECO/IC F39W/T5/841/ECO F39T5/841/HO/ALTO FP39/841/HO/ECO
F49T5/835/HO/ECO/IC F54T5/835/WM/ECO F54T5/835/HO/EA/ALTO 49W -
F49T5/841/HO/ECO/IC F54T5/841/WM/ECO F54T5/841/HO/EA/ALTO 49W -
F49T5/850/HO/ECO/IC F54T5/850/WM/ECO F54T5/850/HO/EA/ALTO 49W -
F54T5/830/HO/ECO/IC F54W/T5/830/ECO F54T5/830/HO/ALTO FP54/830/HO/ECO
F54T5/835/HO/ECO/IC F54W/T5/835/ECO F54T5/835/HO/ALTO FP54/835/HO/ECO
F54T5/841/HO/ECO/IC F54W/T5/841/ECO F54T5/841/HO/ALTO FP54/841/HO/ECO
F54T5/850/HO/ECO/IC F54W/T5/850/ECO F54T5/850/HO/ALTO FP54/850/HO/ECO
F54T5/865/HO/ECO/IC F54W/T5/865/ECO F54T5/865/HO/ALTO FP54/865/HO/ECO
F54T5/835/HO/ECO/XL - - -
F54T5/850/HO/ECO/XL - - -
F80T5/835/HO/ECO/IC F80W/T5/835/ECO F80T5/835/HO FP80/835/HO/ECO
F80T5/841/HO/ECO/IC F80W/T5/841/ECO F80T5/841/HO FP80/841/HO/ECO
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 87
LINEAR FLUORESCENT LAMPS
Cross Reference Guide
HALCO G.E. PHILIPS OSRAM/SYLVANIA
T-5 Ultra Efcient Circline
FC22T5/835 - TL5C 22W/835 FPC22/835
FC22T5/841 - TL5C 22W/840 FPC22/841
FC40T5/835 - TL5C 40W/835 FPC40/835
FC40T5/841 - TL5C 40W/840 FPC40/841
T-8 Rapid Start
F17T8/730/ECO F17T8/SP30/ECO F17T8/TL730/ALTO FO17/730/ECO
F17T8/735/ECO F17T8/SP35/ECO F17T8/TL735/ALTO FO17/735/ECO
F17T8/741/ECO F17T8/SP41/ECO F17T8/TL741/ALTO FO17/741/ECO
F17T8/750/ECO - - -
F17T8/830/ECO F17T8/SPX30/ECO F17T8/TL830/ALTO FO17/830/ECO
F17T8/835/ECO F17T8/SPX35/ECO F17T8/TL835/ALTO FO17/835/ECO
F17T8/841/ECO F17T8/SPX41/ECO F17T8/TL841/ALTO FO17/841/ECO
F17T8/850/ECO - F17T8/TL850/ALTO -
F25T8/730/ECO F25T8/SP30/ECO F25T8/TL730/ALTO FO25/730/ECO
F25T8/735/ECO F25T8/SP35/ECO F25T8/TL735/ALTO FO25/735/ECO
F25T8/741/ECO F25T8/SP41/ECO F25T8/TL741/ALTO FO25/741/ECO
F25T8/750/ECO F25T8/SP50/ECO F25T8/TL750/ALTO -
F25T8/830/ECO F25T8/SPX30/ECO F25T8/TL830/ALTO FO25/830/ECO
F25T8/835/ECO F25T8/SPX35/ECO F25T8/TL835/ALTO FO25/835/ECO
F25T8/841/ECO F25T8/SPX41/ECO F25T8/TL841/ALTO FO25/841/ECO
F25T8ES/830/ECO F32T8/25W/SPX30/ECO F32T8/ADV830/XEW/ALTO 25 WATT FO32/25W/830/XP/SS/ECO
F25T8ES/835/ECO F32T8/25W/SPX35/ECO F32T8/ADV835/XEW/ALTO 25 WATT FO32/25W/835/XP/SS/ECO
F25T8ES/841/ECO F32T8/25W/SPX41/ECO F32T8/ADV841/XEW/ALTO 25 WATT FO32/25W/841/XP/SS/ECO
F25T8ES/850/ECO F32T8/25W/SPX50/ECO F32T8/ADV850/XEW/ALTO 25 WATT FO32/25W/850/XP/SS/ECO
F28T8/830/ECO F28T8/XL/SPX30/ECO F32T8/ADV830/EW/ALTO 28 WATT FO28/830/XP/SS/ECO
F28T8/835/ECO F28T8/XL/SPX35/ECO F32T8/ADV835/EW/ALTO 28 WATT FO28/835/XP/SS/ECO
F28T8/841/ECO F28T8/XL/SPX41/ECO F32T8/ADV841/EW/ALTO 28 WATT FO28/841/XP/SS/ECO
F28T8/850/ECO F28T8/XL/SPX50/ECO F32T8/ADV850/EW/ALTO 28 WATT -
F32T8/730/ECO F32T8/SP30/ECO F32T8/TL730/ALTO FO32/730/ECO
F32T8/735/ECO F32T8/SP35/ECO F32T8/TL735/ALTO FO32/735/ECO
F32T8/741/ECO F32T8/SP41/ECO F32T8/TL741/ALTO FO32/741/ECO
F32T8/750/ECO F32T9/SP50/ECO F32T8/TL750/ALTO FO32/750/ECO
F32T8/765/ECO F32T8/SP65/ECO F32T8/TL765/ALTO FO32/765/ECO
F32T8/830/ECO F32T8/SPX30/ECO F32T8/TL830/ALTO FO32/830/ECO
F32T8/835/ECO F32T8/SPX35/ECO F32T8/TL835/ALTO FO32/835/ECO
F32T8/841/ECO F32T8/SPX41/ECO F32T8/TL841/ALTO FO32/841/ECO
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Cross Reference Guide
88
LINEAR FLUORESCENT LAMPS
HALCO G.E. PHILIPS OSRAM/SYLVANIA
T-8 Rapid Start continued
F32T8/841/ECO/HL F32T8/XL/SPX41/HL/ECO F32T8/ADV841/ALTO -
F32T8/850/ECO F32T8/SPX50/ECO F32T8/TL850/ALTO FO32/850/ECO
F32T8/850/ECO/HL F32T8/XL/SPX50/HL/ECO F32T8/ADV850/ALTO -
F32T8/865/ECO - - -
F32T8BLB - - -
F40T8/735/ECO F40T8/SP35 F40T8/TL735/ALTO FO40/735/ECO
F40T8/741/ECO F40T8/SP41 F40T8/TL741/ALTO FO40/741/ECO
F58T8/840 F58T8/841PLYXLR - -
F70T8/840/M F70T8/840PLYXLR - -
T-12 Rapid Start
F40DX/A F40/DX/ECO F40/DX/ALTO F40/DX
F40/350BL F40BL F40T12/Blacklight F40/350BL
F40BLB F40BLB - F40/BLB/RP
Instant Start - Slimline
F64DL/M F64T12/D F64T12/D F64T12/D
F96T8/735/M F96T8/SP35 F96T8/TL735/PLUS/ALTO FO96/735/ECO
F96T8/741/M F96T8/SP41 F96T8/TL741/PLUS/ALTO FO96/741/ECO
F96T8/850/M F96T8/SPX50 F96T8/TL850/PLUS/ALTO FO96/850/ECO
F96DX/A F96T12/DX F96T12/DX/ALTO F96T12/DX/SS
Rapid Start High Output & Very High Output
F96CWHOES/A F96T12/CW/HO/WM/ECO F96T12/CW/HO/EW/ALTO F96T12/CW/HO/SS/ECO
F96CWHOO/A - F96T12/CW/HO-O/ALTO F96T12/CW/HO/CT/ECO
F96CWVHO/M F96T12/CW/1500 F96T12/CW/VHO-O F96T12/CW/VHO
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 89
LINEAR FLUORESCENT LAMPS
Cross Reference Guide
HALCO G.E. PHILIPS OSRAM/SYLVANIA
U-Bend Fluorescent
FB28/830/6/ECO - - -
FB28/835/6/ECO - - -
FB28/841/6/ECO - - -
FB32/735/6/ECO F32T8/SP35/U/6 FB32T8/TL735/6/ALTO FBO32/735/6/ECO
FB32/741/6/ECO F32T8/SP41/U/6 FB32T8/TL741/6/ALTO FBO32/741/6/ECO
FB32/750/6/ECO - FB32T8/TL750/6/ALTO FBO32/750/6/ECO
FB32/830/6/ECO F32T8/SPX30/U/6 FB32T8/TL830/6/ALTO FBO32/830/6/ECO
FB32/835/6/ECO F32T8/SPX35/U/6 FB32T8/TL835/6/ALTO FBO32/835/6/ECO
FB32/841/6/ECO F32T8/SPX41/U/6 FB32T8/TL841/6/ALTO FBO32/841/6/ECO
FB32/850/6/ECO F32T8/SPX50/U/6 FB32T8/TL850/6/ALTO -
FB31/830/ECO F31T8/SPX30/U - FBO31/830
FB31/835/ECO F31T8/SPX35/U - FBO31/835
FB31/841/ECO F31T8/SPX41/U - FBO31/841
FB31/850/ECO - - -
FB40DX/6/M - FB40/DX/6 -
Brand Name Cross Reference
T5 T5 SilhouettePentron®
T8 T8 TL70/TL80 Octron®
730 SP30 SPEC30 or 730 D30 or 730
830 SPX30 30U or 830 D830
950 C50 C50 DSGN50
ES (Energy Saver) WM (Watt-Miser®) EW (Econo-Watt®) SS (Supersaver®)
Eco-Shield®ECOLUX®ALTO®ECOLOGIC®
ULTRA50 SPX50 50U 850
U-Bend Mod-U-Line®U-Bent Curvalume®
Watt-Miser, ECOLUX and Mod-U-Line are registered trademarks of General Electric. – Silhouette, Econo-Watt and ALTO are registered trademarks of Philips.
– Pentron, Octron, Supersaver, ECOLOGIC and Curvalume are registered trademarks of Osram/Sylvania.
TOC
Symbols, Footnotes and Abbreviations
SYMBOLS
$Energy saving product.
EThis lamp meets Federal Minimum Efciency standards.
ProLume® Eco-Shield® Low-Mercury Fluorescent lamps pass the Federal TCLP for hazardous wastes.
XProduct will be discontinued when inventory is depleted.
LLegislated lamp will not be manufactured after July 14, 2014.
FOOTNOTES
1Average life under specied test conditions with lamps turned off and restarted every three hours.
Lamp life is longer if lamps are started less frequently.
2Commercial average rated life under specied test conditions with lamps turned off and restarted every twelve hours.
Lamp life is longer if lamps are started less frequently.
3
Nominal length is measured from face of base to maximum distant outside point of U-Bend.
Leg spacing measured center to center is approximately 6” for /6 product, 3-5/8” for /3 product
and 1-5/8” for FB31 product.
4Initial lumens are based on 800-mA. operation. For 1000mA. operation, lumens are approximately 10% higher and
wattage approximately 15% higher.
5
This energy saving lamp is only recommended for use on high power factor lead, indoor ballasts that meet ANSI standards.
The lamp is not recommended for use in drafty areas or locations where the ambient temperature drops below 60°F, except as
noted. Do not operate on low power factor ballasts, reduced light or reduced current ballasts, dimming ballasts or emergency
system inverter ballasts.
6Meets the National Energy Policy Act (EPACT) of 1992 exemption for outdoor or cold temperature applications only.
7Lamp designed for use with Programmed Start ballast.
8This lamp should only be operated on high efciency or anti-striation type ballasts.
LINEAR FLUORESCENT
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 90 TOC
ABBREVIATIONS
3Code abbreviation for 3-5/8” U-Bend lamps.
6Code abbreviation for 6” U-Bend lamps.
/730 Sufx used to indicate lamps with CRI of 70+ and color temperature of 3000K.
/735 Sufx used to indicate lamps with CRI of 70+ and color temperature of 3500K.
/741 Sufx used to indicate lamps with CRI of 70+ and color temperature of 4100K.
/750 Sufx used to indicate lamps with CRI of 70+ and color temperature of 5000K.
/765 Sufx used to indicate lamps with CRI of 70+ and color temperature of 6500K.
/830 Sufx used to indicate lamps with CRI of 80+ and color temperature of 3000K.
/835 Sufx used to indicate lamps with CRI of 80+ and color temperature of 3500K.
/841 Sufx used to indicate lamps with CRI of 80+ and color temperature of 4100K.
/850 Sufx used to indicate lamps with CRI of 80+ and color temperature of 5000K.
/865 Sufx used to indicate lamps with CRI of 80+ and color temperature of 6500K.
BL Code abbreviation for Blacklight lamps.
BLB Code abbreviation for Blacklight-Blue lamps.
/CS Sufx used to indicate CoverShield® safety coated lamps.
CW Code abbreviation for Cool White lamps.
CWS Code abbreviation for Cool White Supreme lamps.
CWX Code abbreviation for ProLume® Cool White Deluxe lamps.
DL Code abbreviation for Daylight lamps.
DX Code abbreviation for Daylight lamps.
/ECO Sufx used to indicate Eco-Shield® TCLP compliant lamps.
/ES Sufx used to indicate Energy Saving Fluorescent lamps.
FB Prex used to indicate for Fluorescent U-Bend lamps.
FC Prex used to indicate for Fluorescent Circline lamps.
/HL Sufx used to indicate High Lumen lamps.
/HO Sufx used to indicate High Output lamps.
HOES Code abbreviation to indicate High Output Energy Saver lamps.
HOO Code abbreviation to indicate High Output lamps for outdoor or low temperature operation.
/IC Sufx used to indicate ProLume® Industrial/Commercial service lamps.
/M Sufx used to indicate Major brand Fluorescent lamps (GE, Philips, Osram/Sylvania).
/VHO Sufx used to indicate Very High Output lamps.
WW Code abbreviation for Warm White lamps.
/XL Sufx used to indicate Extended Life lamps.
Symbols, Footnotes and Abbreviations
LINEAR FLUORESCENT
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 91
TOC
®
HIGH INTENSITY DISCHARGE LAMPS
CONTENTS
94
95
96
97
99
100
100
100
100
101
102
102
103
104
105
110
111
How to Read a Table
Ceramic Discharge Metal Halide Lamps
Pulse Start Metal Halide Lamps
Protected Metal Halide Lamps
Standard Metal Halide Lamps
Single Ended Metal Halide Lamps
Double Ended Metal Halide Lamps
Color Metal Halide Lamps
Aquarium Metal Halide Lamps
High Pressure Sodium Lamps
High Pressure Sodium Non-Cycling Lamps
High Pressure Sodium Stand-By Lamps
Mercury Vapor Lamps
Bulb and Base Identication
Cross Reference Guide
General Information and Warning Notices
Symbols, Footnotes and Abbreviations
main
TOC
BULB
Designations indicate shape and size.
Illustrations can be found on page 104
and at the top of each page.
BASE
Indicates base type.
Full base descriptions and
illustrations can be found
on page 104.
PACKAGE QUANTITY
Indicates minimum sell quantity
and smallest shipping carton.
ANSI
CODE
The specic
electrical
characteristics
of a lamp.
PRODUCT CODE
Abbreviated product description
can also be used for ordering.
A key to abbreviations can be
found on page 113.
WATTS
Indicates the
power consumed
by the lamp during
operation.
PRODUCT
NUMBER
Use this number when
placing an order.
INITIAL
LUMENS
The lamp’s
average light
output after the
initial 100 hours
of operation.
CRI
An international
scale from 0 to 100
that indicates the
relative color rendering
value of a light source.
The color rendering
index expresses the
degree to which colors
will look “natural” under
a given light source.
FOOTNOTES &
SYMBOLS
Related footnotes can
be found on page 111.
DESCRIPTION
Bulb nish and other
important information.
MOL
Indicates
maximum
overall length
in inches.
MEAN
LUMENS
The lamp’s
average light
output at 40%
of rated life.
Protected Metal Halide
50 WATT
ED17 Med. 108266 3,13,14,19 MP50/U/MED/PS Clear 1/12 M110/O 3300 2100 10000 5.45” 4000 65
60505 3,13,14,19 MP50/C/U/MED/PS Coated 1/12 M110/O 3200 2000 10000 5.45” 3700 70
70 WATT
ED17 Med. 108268 3,13,14,19 MP70/U/MED/PS Clear 1/12 M98/O 5300 3400 12000 5.45” 4000 65
60508 3,13,14,19 MP70/C/U/MED/PS Coated 1/12 M98/O 5000 3300 12000 5.45” 3700 70
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. ANSI Initial
Lumens
Mean
Lumens
Avg.
Life MOL Color
Temp. CRI
AVERAGE
LIFE
Average rated life
expressed in hours.
COLOR
TEMP.
A term used to
describe the
color of a light
source and is
expressed in
degrees
“Kelvin” (K).
HOW TO READ AN HID LAMP TABLE
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 95
HID LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. ANSI Initial
Lumens
Mean
Lumens
Avg.
Life MOL Color
Temp. CRI
Ceramic Discharge Metal Halide
20 WATT
T4 GU6.5 67010 1,11,18
CDM20/TC/830/GU6.5
Clear 1/24 C156/E 1750 1320 12000 2.44” 3000 85+
G8.5 67012 1,11,18
CDM20/TC/830
Clear 1/24 C156/E 1750 1320 12000 3.35” 3000 85+
T6 G12 67013 1,11,18
CDM20/T6/830
Clear 1/12 C156/E 1750 1320 12000 3.98” 3000 85+
MR16 GX10 67020 3,11,18
CDM20/MR16NFL/830/GX10
Narrow Flood 1/12 C156/O 1200 780 12000 2.56” 3000 85+
PAR20 Med. 67021 3,11,18
CDM20/P20/SP/830
Spot 1/24 C156/O 1200 900 10000 3.74” 3000 85+
67022 3,11,18
CDM20/P20/FL /830
Flood 1/24 C156/O 1200 900 10000 3.74” 3000 85+
39 WATT
T4 GU6.5 67011 1,11,18
CDM35/TC/830/GU6.5
Clear 1/24 C130/E
M130/E 3100 2325 12000 2.44” 3000 80+
G8.5 67006 1,11,18
CDM35/TC/830
Clear 1/24 C130/E
M130/E 3300 2550 12000 3.35” 3000 80+
T6 G12 67002 1,11,18
CDM35/T6/830
Clear 1/12 C130/E
M130/E 3400 2550 12000 3.94” 3000 80+
Rx7S 67016 X 1,11,18
CDM35/TD/830
Clear 1/12 C130/E
M130/E 3100 2350 12000 4.69” 3000 80+
PAR20 Med. 67023 3,11,18
CDM35/P20/SP/830
Spot 1/24 C130/O
M130/O 2100 1575 10000 3.74” 3000 80+
67000 3,11,18
CDM35/P20/FL/830
Flood 1/24 C130/O
M130/O 2100 1575 10000 3.74” 3000 80+
PAR30L Med. 67001 3,11,18
CDM35/P30L/FL/830
Flood 1/6 C130/O
M130/O 2200 1650 10000 4.88” 3000 80+
70 WATT
ED17 Med. 281295 X 1,6,11 MHC70UMED/4K/M Clear Major 1/12 M98/E
M143/E 5900 4130 20000 5.44” 4000 92
T4 G8.5 67007 1,11,18 CDM70/TC/830 Clear 1/24 C/M98/E
C/M139/E 6700 5200 12000 3.35” 3000 85+
T6 G12 67004 1,11,18 CDM70/T6/830 Clear 1/12 C/M98/E
C/M139/E 6700 5300 12000 3.94” 3000 85+
67014 1,11,18 CDM70/T6/942 Clear 1/12 C/M98/E
C/M139/E 6600 5100 12000 3.94” 4200 90+
Rx7S 67017 1,11,18 CDM70/TD/830 Clear 1/12 M85/E
C/M139/E 6500 4875 12000 4.33” 3000 85+
PAR30L Med. 67003 1,11,18 CDM70/P30L/FL/830 Flood 1/6 C/M98/E
C/M139/E 4850 3640 10000 4.88” 3000 85+
67024 1,11,18 CDM70/P30L/SP/830 Spot 1/6 C/M98/E
C/M139/E 4850 3640 10000 4.88” 3000 85+
67026 1,11,18 CDM70/P30L/FL/942 Flood 1/6 C/M98/E
C/M139/E 4300 3225 10000 4.88” 4200 90+
67025 X 1,11,18 CDM70/P30L/SP/942 Spot 1/6 C/M98/E
C/M139/E 4300 3200 10000 4.88” 4200 90+
PAR38 Med. 67028 1,11,18 CDM70/P38/FL/830 Flood 1/6 C/M98/E
C/M139/E 4800 3600 10000 5.64” 3000 85+
67027 1,11,18 CDM70/P38/SP/830 Spot 1/6 C/M98/E
C/M139/E 4800 3600 10000 5.64” 3000 85+
67029 1,11,18 CDM70/P38/FL/942 Flood 1/12 C/M98/E
C/M139/E 4500 3375 10000 5.64” 4200 90+
ED17 Med. 67008 3,11,18 CDM70/U/830/MED Clear 1/12 C/M98/O
C/M139/O 6200 4960 16000 5.64” 3000 85+
Metal Halide
T6
G12
T4
G8.5
T4
GU6.5
MR16
GX10 PAR38T6 Rx7S PAR20 ED17
PAR30L
HID lamp symbols, footnotes and abbreviations are located on pages 111-114.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
96
HID LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. ANSI Initial
Lumens
Mean
Lumens
Avg.
Life MOL Color
Temp. CRI
Ceramic Discharge Metal Halide continued
100 WATT
ED17 Med. 281352 1,6,11 MHC100UMED/4K/M Clear Major 1/12 M90/E
M140/E 9000 6750 20000 5.44” 4000 92
PAR38 Med. 45681 3,11 CDM100/P38/FL/830/M Flood Major 1/6 M90/O
M140/O 6500 4550 10000 5.31” 3000 81
45680 3,11 CDM100/P38/SP/830/M Spot Major 1/6 M90/O
M140/O 6500 4550 10000 5.31” 3000 81
150 WATT
ED17 Med. 67009 1,11,18 CDM150/U/830/MED Clear 1/12 C/M102/E
C/M142/E 14000 11200 16000 5.31” 3000 85+
T6 G12 67005 1,11,26,18 CDM150/T6/830 Clear 1/60 C/M102/E
C/M142/E 14000 10500 12000 3.94” 3000 85+
67015 1,11,26,18 CDM150/T6/942 Clear 1/60 C/M102/E
C/M142/E 13000 9750 12000 3.94” 4200 93+
Pulse Start Metal Halide
50 WATT
ED17 Med. 108228 1,12,13,18 MH50/U/MED/PS Clear 1/12 M110/E 3400 2200 10000 5.45” 4000 65
108232 X 1,12,13,18 MH50/C/U/MED/PS Coated 1/12 M110/E 3300 2100 10000 5.45” 3700 70
70 WATT
ED17 Med. 108246 1,12,13,18 MH70/U/MED/PS Clear 1/12 M98/E 5600 3700 15000 5.45” 4000 65
108248 1,12,13,18 MH70/C/U/MED/PS Coated 1/12 M98/E 5300 3400 15000 5.45” 3700 70
100 WATT
ED17 Med. 108254 1,12,13,18 MH100/U/MED/PS Clear 1/12 M90/E 9000 5900 15000 5.45” 4000 65
108256 1,12,13,18 MH100/C/U/MED/PS Coated 1/12 M90/E 8500 5500 15000 5.45” 3700 70
ED28 Mog. 60003 1,12,13,18 MH100/U/MOG/PS Clear 1/12 M90/E 9000 5900 15000 8.25” 4000 65
125 WATT
ED17 Med. 60007 1,12,13,14,18 MH125/HBU/MED/PS Horizontal
Base Up 1/12 M150/E 12000 8400 15000 5.45” 4000 65
150 WATT
ED17 Med. 108258 1,12,13,18 MH150/U/MED/PS Clear 1/12 M102/E 14000 10500 15000 5.45” 4000 65
ED28 Mog. 108305 1,4,12,13,14,18 MH150/U/PS Clear 1/12 M102/E 14000 10500 15000 8.25” 4000 65
175 WATT
ED17 Med. 60002 1,4,12,13,14,18 MH175/BU/MED/PS Clear Base Up 1/12 M152/E
M137/E 17500 14000 15000 5.45” 4000 65
ED28 Mog. 108274 1,4,12,13,16,18 MH175/BU/PS Clear Base Up 1/12 M152/E
M137/E 17500 14000 15000 8.25” 4000 65
60008 1,12,13,14,18 MH175/HBU/PS Horizontal
Base Up 1/12 M152/E
M137/E 15000 10700 15000 8.25” 4000 65
200 WATT
ED28 Mog. 108284 1,4,12,13,14,18 MH200/BU/PS Clear Base Up 1/12 M136/E 21000 16800 15000 8.25” 4000 65
60006 X 1,4,12,13,14,18 MH200/C/BU/PS Coated Base Up 1/12 M136/E 20000 16000 15000 8.25” 3700 70
Metal Halide
PAR38
T6
G12 ED28ED17 T7 Rx7S
HID lamp symbols, footnotes and abbreviations are located on pages 111-114.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 97
HID LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. ANSI Initial
Lumens
Mean
Lumens
Avg.
Life MOL Color
Temp. CRI
Pulse Start Metal Halide continued
250 WATT
ED28 Mog. 108276 1,4,12,13,14,18 MH250/BU/PS Clear Base Up 1/12 M153/E
M138/E 25000 20000 15000 8.25” 4000 65
60005 1,4,12,13,14,18 MH250/C/BU/PS Coated Base Up 1/12 M153/E
M138/E 23800 19000 15000 8.25” 3700 70
60009 1,12,13,14,18 MH250/HBU/PS Horizontal
Base Up 1/12 M153/E
M138/E 21000 15000 15000 8.25” 4000 65
320 WATT
ED28 Mog. 108278 1,4,6,12,13,14,18 MH320/BU/PS Clear Base Up 1/12 M154/E
M132/E 33000 26000 20000 8.25” 4000 65
60004 X 1,4,6,12,13,14,18 MH320/C/BU/PS Coated Base Up 1/12 M154/E
M132/E 31000 25000 20000 8.25” 3700 70
60010 1,12,13,14,18 MH320/HBU/PS Clear Horizontal
Base Up 1/12 M154/E
M132/E 31000 23000 15000 8.25” 4000 65
350 WATT
ED37 Mog. 108291 1,4,6,12,13,14,18 MH350/BU/PS Clear Base Up 1/6 M131/E 37000 29000 20000 11.50” 4000 65
400 WATT
ED28 Mog. 60012 1,6,12,13,18 MH400/U/ED28/PS Clear 1/12 M155/E
M135/E 39000 33000 20000 8.25” 4000 65
ED37 Mog. 60011 1,6,12,13,18 MH400/U/PS Clear 1/6 M155/E
M135/E 39000 35000 20000 11.50” 4000 65
108280 1,4,5,6,12,13,14,18 MH400/BU/PS Clear Base Up 1/6 M155/E
M135/E 44000 35000 20000 11.50” 4000 65
750 WATT
ED37 Mog. 60016 1,12,13,18 MH750/HBU/PS Clear Horizonal
Base Up 1/6 M149/E 75000 55000 10000 11.50” 4000 65
875 WATT
BT37 Mog. 60014 1,12,13,18 MH875/U/PS Clear 1/6 M166/E 96000 82500 15000 11.50” 4000 65
1000 WATT
BT37 Mog. 60015 1,12,13,18 MH1000/U/PS Clear 1/6 M141/E 110000 96000 15000 11.50” 4000 65
Protected Metal Halide
50 WATT
ED17 Med. 108266 3,12,13,18 MP50/U/MED/PS Clear 1/12 M110/O 3300 2100 10000 5.45” 4000 65
60505 3,12,13,18 MP50/C/U/MED/PS Coated 1/12 M110/O 3200 2000 10000 5.45” 3700 70
70 WATT
ED17 Med. 108268 3,12,13,18 MP70/U/MED/PS Clear 1/12 M98/O 5300 3400 12000 5.45” 4000 65
60508 3,12,13,18 MP70/C/U/MED/PS Coated 1/12 M98/O 5000 3300 12000 5.45” 3700 70
100 WATT
ED17 Med. 108270 3,12,13,18 MP100/U/MED/PS Clear 1/12 M90/O 8500 5500 15000 5.45” 4000 65
60507 3,12,13,18 MP100/C/U/MED/PS Coated 1/12 M90/O 8100 5300 15000 5.45” 3700 70
150 WATT
ED17 Med. 108272 3,12,13,18 MP150/U/MED/PS Clear 1/12 M102/O 13300 10000 15000 5.45” 4000 65
60503 3,12,13,18 MP150/C/U/MED/PS Coated 1/12 M102/O 12600 9500 15000 5.45” 3700 70
Metal Halide
BT37ED37 ED17ED28
HID lamp symbols, footnotes and abbreviations are located on pages 111-114.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Protected Metal Halide continued
175 WATT
ED17 Med. 108282 3,12,13 MP175/U/MED Clear 1/12 M57/O 14000 9100 10000 5.45” 4000 65
90402 X 3,12,13,14,25 MP175/U/MED/CSTF Clear CoverShield®1/12 M57/O 14000 9100 10000 5.45” 4000 65
ED28 EX39 108286 3,12,14,16 MP175/BU Clear Base Up 1/12 M57/O 14000 9100 10000 8.25” 4000 65
90400 X 3,12,13,14,25 MP175/BU/CSTF Clear Base Up
CoverShield®1/12 M57/O 14000 9100 10000 8.25” 4000 65
200 WATT
ED28 EX39 60511 3,12,13,14,16,18 MP200/BU/PS Clear Base Up 1/12 M136/O 20000 16000 15000 8.25” 4000 65
60509 X 3,12,13,14,16,18 MP200/C/BU/PS Coated Base Up 1/12 M136/O 19000 15200 15000 8.25” 3700 70
250 WATT
ED28 EX39 108288 3,12,14,16 MP250/BU Clear Base Up 1/12 M58/O 21800 14200 10000 8.25” 4000 65
60710 3,12,14,16 MP250/C/BU Coated Base Up 1/12 M58/O 20000 13000 10000 8.25” 3700 70
108298 3,12,13,14,16,18 MP250/BU/PS Clear Base Up 1/12 M153/O
M138/O 23800 19000 15000 8.25” 4000 65
60510 3,12,13,14,16,18 MP250/C/BU/PS Coated Base Up 1/12 M153/O
M138/O 22600 17600 15000 8.25” 3700 70
90401 X 3,12,13,14,25 MP250/BU/CSTF Clear Base Up
CoverShield®1/12 M58/O 21800 14200 10000 8.25” 4000 65
320 WATT
ED28 EX39 108290 3,4,6,12,13,14,18 MP320/BU/PS Clear Base Up 1/12 M154/O
M132/O 31000 25000 20000 8.25” 4000 65
360 WATT
ED37 EX39 108292 $ 3,6,7,12,14,16,24 MP360/BU/ES Clear Base Up
Energy Saver 1/6 M165/O
M59/O 36000 23500 20000 11.50” 4000 65
400 WATT
ED37 EX39 108294 3,6,12,14,16 MP400/BU Clear Base Up 1/6 M59/O 36000 23500 20000 11.50” 4000 65
60700 3,6,12,14,16 MP400/C/BU Coated Base Up 1/6 M59/O 34000 22000 20000 11.50” 3700 70
108296 3,4,5,6,12,13,14,18 MP400/BU/PS Clear Base Up 1/6 M155/O
M135/O 41000 33000 20000 11.50” 4000 65
60502 3,6,12,14,16,25 MP400/BU/CSTF Clear Base Up
CoverShield®1/6 M59/O 36000 23500 20000 11.50” 4000 65
450 WATT
ED37 EX39 60512 X 3,6,12,13,14,18 MP450/BU/PS Clear Base Up 1/6 M144/O 47000 35000 20000 11.50” 4000 65
575 WATT
BT37 EX39 60513 X 3,6,12,13,14,18 MP575/BU/PS Clear Base Up 1/6 M178/O 60000 45000 20000 11.50” 4000 65
750 WATT
BT37 EX39 60501 3,4,12,14,18 MP750/BU/PS Clear Base Up 1/6 M149/O 72000 52000 10000 11.50” 4000 65
875 WATT
BT37 EX39 60514 3,6,12,13,14,18 MP875/BU/PS Clear Base Up 1/6 M166/O 95000 72000 20000 11.50” 4000 65
1000 WATT
BT56 EX39 60720 3,12,13,14,18 MP1000/BU Clear Base Up 1/6 M47/O 110000 88000 10000 15.40” 4000 65
Metal Halide
ED37 BT37ED28ED17 BT56
98
HID LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. ANSI Initial
Lumens
Mean
Lumens
Avg.
Life MOL Color
Temp. CRI
HID lamp symbols, footnotes and abbreviations are located on pages 111-114.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T15
Metal Halide
Standard Metal Halide
100 WATT
ED17 Med. 64818 1,12,16,20,21 MH100UMED/M Clear Major 1/20 M90/E 8500 4675 12000 5.43” 4000 65
175 WATT
ED17 Med. 108262 1,12,16,20,21 MH175/U/MED Clear 1/12 M57/E 15000 9100 10000 5.45” 4000 65
108264 1,12,16,20,21 MH175/C/U/MED Coated 1/12 M57/E 14800 8600 10000 5.45” 3700 70
ED28 Mog. 108200 1,12,16,20,21 MH175/U Clear 1/12 M57/E 15200 9100 10000 8.25” 4000 65
108202 1,12,16,20,21 MH175/C/U Coated 1/12 M57/E 14800 8600 10000 8.25” 3700 70
250 WATT
ED28 Mog. 108204 1,12,16,20,21 MH250/U Clear 1/12 M58/E 21000 13700 10000 8.25” 4000 65
108206 1,12,16,20,21 MH250/C/U Coated 1/12 M58/E 20000 13000 10000 8.25” 3700 70
ED28 Mog. 108604 1,12,16,20,21,25 MH250/U/CSTF Clear
CoverShield®1/12 M58/E 21000 13700 10000 8.25” 4000 65
POMB 60303 X 1,8,12,16,18 MH250/HOR Clear Horizontal 1/12 M58/E 23000 15000 10000 8.25” 4000 65
60302 X 1,8,12,16,18 MH250/C/HOR Coated Horizontal 1/12 M58/E 22000 14300 10000 8.25” 3700 70
T15 Mog. 108220 1,12,16,20,21 MH250/HBU/T15 Clear Horizontal
Base Up 1/12 M58/E 21000 14500 10000 8.30” 4000 65
360 WATT
ED37 Mog. 108212 $ 1,6,7,8,12,14,16,24 MH360/BU/ES Clear Base Up
Energy Saver 1/6 M165/E
M59/E 36000 23000 20000 11.50” 4000 65
400 WATT
BT37 Mog. 64450 1,6,12,15 MS400/BU Clear Base Up
Major 1/6 M59/E 42000 27000 20000 11.50” 4000 65
ED18 Mog. 108218 1,6,12,15 MH400/HBU/ED18 Clear Horizontal
Base Up 1/12 M59/E 36000 23000 20000 9.75” 4000 65
ED28 Mog. 108216 1,6,12,16,20,21 MH400/U/ED28 Clear 1/12 M59/E 36000 23000 20000 8.25” 4000 65
60201 1,6,12,16,20,21 MH400/C/U/ED28 Coated 1/12 M59/E 34000 22000 20000 8.25” 3700 70
ED37 Mog. 108208 1,6,12,16,20,21 MH400/U Clear 1/6 M59/E 36000 23000 20000 11.50” 4000 65
108210 1,6,12,16,20,21 MH400/C/U Coated 1/6 M59/E 34000 22000 20000 11.50” 3700 70
108600 1,6,12,16,20,21,25 MH400/U/CSTF Clear
CoverShield®1/6 M59/E 36000 23000 20000 11.50” 4000 65
POMB 60301 X 1,6,8,12,16,18 MH400/C/HOR Coated Horizontal 1/6 M59/E 36800 23900 20000 11.50” 3700 70
1000 WATT
BT37 Mog. 108226 1,12,16,20,21,18 MH1000/U/BT37 Clear 1/6 M47/E 110000 71000 12000 11.50” 4000 65
BT56 Mog. 108222 1,12,16,20,21,18 MH1000/U Clear 1/6 M47/E 110000 71000 12000 15.40” 4000 65
1500 WATT
BT56 Mog. 837405 1,12,15 MH1500/HBU Clear Base Up/
Horizontal Major 1/6 M48/E 165000 140000 3000 15.40” 3900 65
108214 1,12,14,18 MH1500/BU Clear Base Up 1/6 M48/E 161000 136000 3000 15.40” 3400 65
ED37BT56BT37ED28ED17 ED18
99
HID LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. ANSI Initial
Lumens
Mean
Lumens
Avg.
Life MOL Color
Temp. CRI
HID lamp symbols, footnotes and abbreviations are located on pages 111-114.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Single Ended Metal Halide
70 WATT
T6 G12 108434 1,2,11,12,18,23 MH70SE/UVS/3K Clear UV-Stop 1/24 M85/E 5600 3600 10000 4.30” 3200 70
108428 1,2,11,12,18,23 MH70SE/UVS/4K Clear UV-Stop 1/24 M85/E 5600 3600 10000 4.30” 4200 70
150 WATT
T7 G12 108430 1,2,11,12,18,23 MH150SE/UVS/3K Clear UV-Stop 1/24 M81/E 14000 10500 10000 4.30” 3200 65
108432 1,2,11,12,18,23 MH150SE/UVS/4K Clear UV-Stop 1/24 M81/E 14000 10500 10000 4.30” 4200 65
Double Ended Metal Halide
70 WATT
T6 R7S 108402 1,2,12,18,23 MH70DE/UVS/3K Clear UV-Stop 1/24 M85/E 5600 3400 10000 4.65” 3000 70
108400 1,2,12,18,23 MH70DE/UVS/4K Clear UV-Stop 1/24 M85/E 5600 3600 10000 4.65” 4000 70
100 WATT
T7 R7S 108408 X 1,2,12,18,23 MH100DE/UVS/3K Clear UV-Stop 1/24 M91/E 8000 4680 10000 4.65” 3000 70
108406 X 1,2,12,18,23 MH100DE/UVS/4K Clear UV-Stop 1/24 M91/E 8000 5200 10000 4.65” 4000 70
150 WATT
T7 R7S 108412 X 1,2,12,18,23 MH150DE/UVS/3K Clear UV-Stop 1/24 M81/E 12000 8400 10000 5.37” 3000 70
250 WATT
T8 FC2 108414 1,12,18,23 MH250DE/4K Clear 1/24 M80/E 20000 13000 8000 6.42” 4200 70
Color Metal Halide
150 WATT
T7 R7S 108422 X 1,2,12,18,23 MH150DE/UVS/BDX Blue UV-Stop 1/24 M81/E - - 8000 3.37” - -
108424 X 1,2,12,18,23 MH150DE/UVS/GDX Green UV-Stop 1/24 M81/E - - 8000 3.37” - -
108426 X 1,2,12,18,23 MH150DE/UVS/MDX Magenta UV-Stop 1/24 M81/E - - 8000 3.37” - -
400 WATT
BT37 Mog. 61001 X 1,13,17,21,19 MH400/BU/BDX Blue 1/6 M59/E - - 5000 11.50” - -
61002 X 1,13,17,21,19 MH400/BU/GDX Green 1/6 M59/E - - 5000 11.50” - -
1000 WATT
BT56 Mog. 61004 X 1,12,16,20,18 MH1000/BU/BDX Blue 1/6 M47/E - - 5000 15.37” - -
Aquarium Metal Halide
150 WATT
T7 R7S 108420 X 1,2,12,18 MH150DE/UVS/10K Clear UV-Stop 1/24 M81/E 9000 - 8000 5.37” 10000 80
400 WATT
T15 Mog. 108416 1,12,18 MH400/U/T15/10K Clear 1/12 M59/E 25000 - 10000 9.76” 10000 90
T6/T7
G12 BT56
T6/T7
R7S
Metal Halide
BT37
T15/T16
T8
FC2
100
HID LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. ANSI Initial
Lumens
Mean
Lumens
Avg.
Life MOL Color
Temp. CRI
HID lamp symbols, footnotes and abbreviations are located on pages 111-114.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
High Pressure Sodium
High Pressure Sodium
35 WATT
ED17 Med. 108102 10,13,15 LU35/MED/ECO Clear 1/12 S76 2200 1980 24000 5.45” 2000 20
108103 X 10,13,15 LU35/MED/D Diffused 1/12 S76 2000 1800 24000 5.45” 2000 20
50 WATT
ED17 Med. 108104 10,13,15 LU50/MED/ECO Clear 1/12 S68 3800 3420 24000 5.45” 2000 20
108105 X 10,13,15 LU50/MED/D Diffused 1/12 S68 3400 3060 24000 5.45” 2000 20
ED23.5 Mog. 208120 10,13,15 LU50/ECO Clear 1/12 S68 3800 3420 24000 7.75” 2000 20
208121 X 10,13,15 LU50/D Diffused 1/12 S68 3400 3060 24000 7.75” 2000 20
70 WATT
ED17 Med. 108106 10,13,15 LU70/MED/ECO Clear 1/12 S62 6000 5400 24000 5.45” 2000 20
ED23.5 Mog. 208122 10,13,15 LU70/ECO Clear 1/12 S62 6000 5400 24000 7.75” 2000 20
208123 X 10,13,15 LU70/D Diffused 1/12 S62 5500 4950 24000 7.75” 2000 20
100 WATT
ED17 Med. 108108 10,13,15 LU100/MED/ECO Clear 1/12 S54 9000 8100 24000 5.45” 2000 20
108109 X 10,13,15 LU100/MED/D Diffused 1/12 S54 8100 7290 24000 5.45” 2000 20
ED23.5 Mog. 208124 10,13,15 LU100/ECO Clear 1/12 S54 9000 8100 24000 7.75” 2000 20
208125 X 10,13,15 LU100/D Diffused 1/12 S54 8100 7290 24000 7.75” 2000 20
150 WATT
ED17 Med. 108110 10,13,15 LU150/MED/ECO Clear 1/12 S55 15000 13500 24000 5.45” 2000 20
108111 X 10,13,15 LU150/MED/D Diffused 1/12 S55 13500 12150 24000 5.45” 2000 20
ED23.5 Mog. 208126 10,13,15 LU150/ECO Clear 1/12 S55 15000 13500 24000 7.75” 2000 20
ED28 Mog. 64002 10,13,15 LU150/100/ECO Clear 1/12 S55 15000 13500 24000 8.98” 2000 20
200 WATT
ED18 Mog. 208128 10,13,15 LU200/S66/ECO Clear 1/12 S66 22000 19800 24000 9.75” 2000 20
250 WATT
ED18 Mog. 208130 10,13,15 LU250/ECO Clear 1/12 S50 28000 25200 24000 9.75” 2000 20
400 WATT
ED18 Mog. 208132 10,13,15 LU400/ECO Clear 1/12 S51 48000 43200 24000 9.75” 2000 20
1000 WATT
ED25 Mog. 279547 10,13,15 LU1000/ECO Clear 1/6 S52 130000 117000 24000 15.08” 2000 20
ED17 ED23.5 ED18 ED28
101
HID LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. ANSI Initial
Lumens
Mean
Lumens
Avg.
Life MOL Color
Temp. CRI
ED25
HID lamp symbols, footnotes and abbreviations are located on pages 111-114.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
High Pressure Sodium Non-Cycling
70 WATT
ED23.5 Mog. 64500 10,13,15 LU70/NC Clear Non-Cycling 1/12 S62 6300 5670 20000 7.75” 2000 >20
100 WATT
ED23.5 Mog. 64502 10,13,15 LU100/NC Clear Non-Cycling 1/12 S54 10500 9500 20000 7.75” 2000 >20
150 WATT
ED23.5 Mog. 64504 10,13,15 LU150/NC Clear Non-Cycling 1/12 S55 16000 14400 20000 7.75” 2000 >20
250 WATT
ED23.5 Mog. 64506 10,13,15 LU250/NC Clear Non-Cycling 1/12 S50 32000 28800 20000 9.75” 2000 >20
High Pressure Sodium Stand-By
70 WATT
ED23.5 Mog. 64501 10,13,15 LU70/SBY/LL Clear Stand-by
Twin Arc Tube 1/12 S62 6000 5670 48000 7.75” 2000 >20
100 WATT
ED23.5 Mog. 64503 10,13,15 LU100/SBY/LL Clear Stand-by
Twin Arc Tube 1/12 S54 9600 8600 48000 7.75” 2000 >20
150 WATT
ED23.5 Mog. 208402 10,13,15 LU150/SBY/LL Clear Stand-by
Twin Arc Tube 1/12 S55 15000 13500 48000 7.75” 2000 20
200 WATT
ED23.5 Mog. 64505 10,13,15 LU200/SBY/LL Clear Stand-by
Twin Arc Tube 1/12 S66 22000 19800 48000 9.75” 2100 >20
250 WATT
ED23.5 Mog. 64507 10,13,15 LU250/SBY/LL Clear Stand-by
Twin Arc Tube 1/12 S50 28000 25200 48000 9.75” 2000 >20
400 WATT
ED23.5 Mog 208400 10,13,15 LU400/SBY/LL Clear Stand-by
Twin Arc Tube 1/12 S51 48000 43200 48000 9.75” 2000 20
64508 10,13,15 LU400/NC Clear Stand-by
Twin Arc Tube 1/12 S51 53500 48000 20000 9.75” 2000 >20
High Pressure Sodium
102
HID LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. ANSI Initial
Lumens
Mean
Lumens
Avg.
Life MOL Color
Temp. CRI
ED23.5
HID lamp symbols, footnotes and abbreviations are located on pages 111-114.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 103
HID LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. ANSI Initial
Lumens
Mean
Lumens
Avg.
Life MOL Color
Temp. CRI
Mercury Vapor
Mercury Vapor
50 WATT
ED17 Med. 108302 17,19,21 MV50DX Deluxe White 1/12 H46 1600 1280 6000 5.45” 4000 45
75 WATT
ED17 Med. 108304 17,21 MV75DX Deluxe White 1/12 H43 2700 2250 12000 5.45” 4000 45
100 WATT
ED17 Med. 108306 17,21 MV100DX Deluxe White 1/12 H38 4600 3600 24000 5.45” 4000 45
ED23.5Mog. 108308 17,21 MV100DXMOG Deluxe White 1/12 H38 4600 3600 24000 7.50” 4000 45
175 WATT
ED28 Mog. 108332 21 MV175CL Clear 1/12 H39 7800 7250 24000 8.50” 5800 25
108310 17,21 MV175DX Deluxe White 1/12 H39 8500 6900 24000 8.50” 4000 45
250 WATT
ED28 Mog. 108334 21 MV250CL Clear 1/12 H37 12800 10535 24000 8.50” 5800 25
108312 17,21 MV250DX Deluxe White 1/12 H37 13500 11100 24000 8.50” 4000 45
400 WATT
ED37 Mog. 108336 21 MV400CL Clear 1/6 H33 22000 18900 24000 10.38” 5800 25
108314 17,21 MV400DX Deluxe White 1/6 H33 23000 19100 24000 10.38” 4000 45
1000 WATT
BT56 Mog. 869331 9,17,21 MV1000DX Deluxe White
Major 1/6 H36 58000 48500 24000 15.38” 4000 45
Mercury Vapor Reector
100 WATT
R40 Med. 108350 17 MV100DX/R40 Deluxe White
Reector 1/12 H38 2450 2000 16000 6.89” 5800 45
175 WATT
R40 Med. 108356 17 MV175DX/R40 Deluxe White
Reector 1/12 H39 6200 4900 24000 6.89” 5800 45
ED17 ED28ED23.5 BT56 R40ED37
HID lamp symbols, footnotes and abbreviations are located on pages 111-114.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
104
Bulb and Base Identication Guide
Bulb Shapes
Base Types
BT37 BT56 ED17 ED18 ED23.5 ED25 ED37
PAR20/PAR30L PAR38 R40 T6/T7/T8
Double
Ended
Rx7S
T6/T7
Single
Ended
G12
T15/
T16
FC2 G12
Medium
Bi-Bin
R7S/Rx7s
Recessed
Single Contact
POMB
Position Oriented
Mogul Base
EX39
Exclusionary
Mogul Base
E39
Mogul
E26/27
Medium
MR16
GX10
T4
G8.5
T4
GU6.5
GX10
GU6.5 G8.5
ED28
HID LAMPS
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Cross Reference Guide
105
HID LAMPS
HALCO G.E. PHILIPS OSRAM/SYLVANIA ANSI
CDM CMH®MasterColor®Powerball®
CDM20/MR16NFL/830/GX10 CMH20/MR16/830/FL - - C156
CDM20/P20/FL/830 CMH20/PAR20/FL - - C156
CDM20/P20/SP/830 CMH20/PAR20/SP - - C156
CDM20/T6/830 CMH20/T/U/G12 - - C156/E
CDM20/TC/830 CMH20/TC/U/830/G8.5 - MC20TC/U/G8.5/830 C156/E
CDM20/TC/830/GU6.5 CMH20/TC/U/830/GU6.5 - - C/M-130/E
CDM35/P20/SP/830 CMH39/PAR20/830/SP10 CDM35/PAR20/M/SP3K MCP39PAR20/U/830/SP C/M-130/O
CDM35/P20/FL/830 CMH39/PAR20/830/FL30 CDM35/PAR20/M/FL3K MCP39PAR20/U/830/FL C/M-130/O
CDM35/P30L/SP/830/M CMH39/PAR30L/830/SP10 CDM35/PAR30L/M/SP MCP39PAR30LN/U/830/SP C/M-130/O
CDM35/P30L/FL/830 CMH39/PAR30L/830/FL25 CDM35/PAR30L/M/FL MCP39PAR30LN/U/830/FL C/M-130/O
CDM35/T6/830 CMH39/T/U/830/G12 CDM35/T6/830 MC39T6/U/G12/830 C/M-130/E
CDM35/TC/830 CMH39/TC/U/830/G8.5 CDM35/TC/830 MC39TC/U/G8.5/830 C/M-130/E
CDM35/TC/830/GU6.5 - CDM35/TC/830/GU6.5 - C/M-130/E
CDM35/TD/830 - CDM70/TD/830 - C/M-130/E
CDM70/P30L/SP/830 CMH70/PAR30L/830/SP15 CDM70/PAR30L/M/SP MCP70PAR30LN/U/830/SP C/M-98/O | C/M-139/O
CDM70/P30L/FL/830 CMH70/PAR30L/830/FL40 CDM70/PAR30L/M/FL MCP70PAR30LN/U/830/FL C/M-98/O |C/M-139/O
CDM70/P30L/SP/942 - CDM70/PAR30L/M/SP/4K - C/M-98/O | C/M-139/O
CDM70/P30L/FL/942 - CDM70/PAR30L/M/FL/4K - C/M-98/O | C/M-139/O
CDM70/P38/SP/830 CMH70/PAR38/830/SP15 CDM70/PAR38/M/SP - C/M-98/O | C/M-139/O
CDM70/P38/FL/830 CMH70/PAR38/830/FL25 CDM70/PAR38/M/FL - C/M-98/O | C/M-139/O
CDM70/P38/FL/942 - CDM70/PAR38/M/FL/4K - C/M-98/O | C/M-139/O
CDM70/T6/830 - CDM70/T6/830 - C/M-98/E | C/M-139/E
CDM70/T6/942 - CDM70/T6/942 - C/M-98/E | C/M-139/E
CDM70/TC/830 CMH70/TC/U/830/G8.5 CDM70/TC/830 MC70TC/U/G8.5/830 C/M-98/E | C/M-139/E
CDM70/TD/830 CMH70/TD/830/RX7s CDM70/TD/830 MC70T6/DE/830 M85/E | C/M-139/E
CDM70/U/830/MED CMH70/C/U/830/MED/O MHC70/C/U/M/3K/ALTO MCP70/C/U/MED/830 C/M-98/E | C/M-139/E
CDM100/P38/FL/830/M CMH100/PAR38/830/FL25 CDM100/PAR38/FL/3K/ALTO MCP100PAR38/U/FL/830/ECO M90/O | M140/O
CDM100/P38/SP/830/M CMH100/PAR38/830/SP15 CDM100/PAR38/SP/3K/ALTO MCP100PAR38/U/SP/830/ECO M90/O | M140/O
CDM150/T6/830 CMH150/T/U/830/G12 CDM150/T6/830 MC150T6/U/G12/830 C/M-102/E | C/M-142/E
CDM150/T6/942 CMH150/T/U/942/G12 CDM150/T6/942 MC150T6/U/G12/942 C/M-102/E | C/M-142/E
CDM150/TD/830 CMH150/TD/830/Rs7s CDM150/TD/830 MC150T6/DE/830 M81/E | C/M-102/E | C/M-142/E
CDM150/U/830/MED CHM150/U/830/MED/O MHC150/U/MP/3K/ALTO MCP150/U/MED/830 C/M-102/E | C/M-142/E
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Cross Reference Guide
106
HID LAMPS
HALCO G.E. PHILIPS OSRAM/SYLVANIA ANSI
Metal Halide Multi-Vapor®Metal Halide Metalarc®
MH50/U/MED/PS MXR50/U/MED/O MH50/U/M MP50/U/MED M110/E
MH50/C/U/MED/PS MXR50/C/U/MED MH50/C/U/M MP50/C/U/MED M110/E
MH70/U/MED/PS MXR70/U/MED - MP70/U/MED M98/E
MH70/C/U/MED/PS MXR70/C/U/MED - MP70/C/U/MED M98/E
MH70DE/UVS/3K ARC70/TD/UVC/730 CDM70/TD/830 HQI-DE70/WDX M85/E
MH70DE/UVS/4K ARC70/TD/UVC/743 MHN70/TD/840 HQI-DE70/NDX M85/E
MH70SE/UVS/3K CMH70/T/U/830/G12 CDM70/T6/830 - M85/E
MH70SE/UVS/4K CMH70/T/U/943/G12 CDM70/T6/942 - M85/E
MH100/U/MED/PS MXR100/U/MED - MP100/U/MED M90/E
MH100/C/U/MED/PS MXR100/C/U/MED - MP100/C/U/MED M90/E
MH100/U/MOG/PS - - - M90/E
MH125/HBU/MED/PS - - - M150/E
MH150/U/MED/PS MXR150/U/MED MP150/U/MED - M102/E
MH150/U/PS - - - M102/E
MH150DE/UVS/10K - - - M81/E
MH150DE/UVS/3K ARC150/TD/UVC/730 MHN150/TD/840 HQI-DE150/WDX M81/E
MH150DE/UVS/4K ARC150/TD/UVC/742 - HQI-DE150/NDX M81/E
MH150DE/UVS/BDX - - - M81/E
MH150DE/UVS/GDX - - - M81/E
MH150SE/UVS/3K ARC150T/U/830G12 - - M81/E
MH150SE/UVS/4K ARC150T/U/840G12 - HQI-SE150/NDX M81/E
MH175/BU/PS MVR175/VBU/PA MS175/BU/PS MS175/PS/BU-ONLY M152/E-M137/E
MH175/BU/MED/PS MVR175/VBU/MED/PA MS175/BU/PS MS175/PS/BU M152/E-M137/E
MH175/HBU/PS MVR175/VBU/PA - - M152/E-M137/E
MH175/U MVR175/U MH175/U M175/U M57/E
MH175/U/MED MVR175/U/MED MH175/U/M M175/U/MED M57/E
MH175/C/U MVR175/C/U MH175/C/U M175/C/U M57/E
MH175/C/U/MED MVR175/C/U/MED MH175/C/U/M M175/C/U/MED M57/E
MH200/BU/PS - - MS200/PS/BU-ONLY/BT28 M136/E
MH200/C/BU/PS - - MS200/C/PS/BU/BU-ONLY/BT28 M136/E
MH250/HBU/T15 - - - M58/E
MH250/HBU/PS MVR250/VBU/PA MS250/BU/PS MP250/PS/BU-ONLY M153/E-M138/E
MH250/BU/PS MVR250/VBU/PA MS250/BU/PS MP250/PS/BU-ONLY M153/E-M138/E
MH250/C/BU/PS MVR250/C/VBU/PA - MP250/C/PS/BU-ONLY M153/E-M138/E
MH250/C/U MVR250/C/U MS250/C/U M250/C/U M58/E
MH250/U MVR250/U MH250/U M250/U M58/E
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Cross Reference Guide
107
HID LAMPS
HALCO G.E. PHILIPS OSRAM/SYLVANIA ANSI
Metal Halide Multi-Vapor®Metal Halide Metalarc®
MH250DE/4K - - - M80/E
MH320/VBU/PS MVR320/VBU/HO/PA MS320/BU/PS MS320/PS/BU M154/E-M132/E
MH320/HBU/PS MVR320/HOR/PA MS320/PS/U M320/PS/BU-HOR M154/E-M132/E
MH320/BU/PS MVR320/VBU/XHO/PS MS320/U/PS MP320/350/PS/BU-ONLY/BT28 M154/E-M132/E
MH320/C/BU/PS MVR320/C/VBU/XHO/PS MS320/C/U/PS MS320/C/PS/BU-HOR M154/E-M132/E
MH350/BU/PS MVR350/VBU/XHO/PA MS350/BU/PS MP350/400/PS/BU-ONLY M131/E
MH360/BU/ES MVR360/VBU/WM/HO - - M165/E-M59/E
MH400/BU/PS MVR400/VBU/HO/PA MS400/BU/PS MS400/PS/BU-ONLY M155/E-M135/E
MH400/BU/LU MVR400/VBR/R - - S51/E
MH400/HBU/ED18 - - - M59/E
MH400/U MVR400/U MH400/U M400/U M59/E
MH400/U/ED28 MVR400/U/ED28 MH400/U/ED28 M400/U/BT28 M59/E
MH400/U/ED28/PS MVR400/HOR/ED28/PA - M400/PS/U/BT28 M155/E-M135/E
MH400/U/PS MVR400/HOR/PA MS400/HOR/PS M400/PS/U M155/E-M135/E
MH400/U/T15/10K - - - M59/E
MH400/C/U MVR400/C/U MH400/C/U M400/C/U M59/E
MH400/C/U/ED28 MVR400/C/U/ED28 MH400/U/ED28 M400/C/U/BT28 M59/E
MH450/BU/PS - - - M144/E
MH875/U/PS - - - M166/E
MH1000/U MVR1000/U MH1000/U M1000/U M47/E
MH1000/U/PS MVR1000/U/BT37/PA M1000/PS/U/BT37 MS1000/BU/BT37/PS M141/E
MH1000/U/BT37 MVR1000/U/BT37 M1000/U/BT37 MH1000/U/BT37 M47/E
MH1500/BU MVR1500/HBU MH1500/U M1500/BU-HOR M48/E
MP50/C/U/MED/PS MXR50/C/U/MED/O - MP50/C/U/MED M110/O
MP50/U/MED/PS MXR50/U/MED/O - MP50/U/MED M110/O
MP70/C/U/MED/PS MXR70/C/U/MED/O - MP70/C/U/MED M98/O
MP100/U/MED/PS MXR100/U/MED/O - MP100/U/MED M90/O
MP150/U/MED/PS MXR150/U/MED/O - MP150/U/MED M102/O
MP150/C/U/MED/PS MXR150/C/U/MED/O MP150/C/U/MED - M102/O
MP175/BU MPR175/VBU/O MP175/BU MP175/BU-ONLY M57/O
MP175/BU/PS MPR175/VBU/O MP175/BU MP175/BU-ONLY M152/O-M137/O
MP175/U/MED - - MP175/BU-ONLY/MED M57/O
MP200/BU/PS - - - M136/O
MP200/C/BU/PS - - - M136/O
MP250/BU MPR250/VBU/O MP250/BU MP250/BU-ONLY M58/O
MP250/BU/PS - - MP250/PS/BU-ONLY M153/O-M138/O
MP250/C/BU MPR250/C/VBU/O - MP250/C/BU-ONLY M58/O
MP250/C/BU/PS - MP250/C/PS/BU-ONLY M153/O-M138/O
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Cross Reference Guide
108
HID LAMPS
HALCO G.E. PHILIPS OSRAM/SYLVANIA ANSI
Metal Halide Multi-Vapor®Metal Halide Metalarc®
MP320/BU/PS MPR320/VBU/XHO/PA MP320/BU/PS MP320/350/PS/BU-ONLY/BT28 M154/O-M132/O
MP320/C/BU/PS MPR320/C/VBU/XHO/PA MP320/C/BU/PS MP320/350/C/PS/BU-ONLY/BT28 M154/O-M132/O
MP360/BU/ES MPR360/VBU/WM/HO/O MP360/BU/EW MSP360/SS/BU-ONLY M59/O or M165/O
MP400/BU MVT400/VBU MHT400/U MPT400/BU M59/O
MP400/BU/PS - - - M155/O-M135/O
MP400/C/BU MVT400/C/VBU MHT400/C/U MPT400/C/BU M155/O-M135/O
MP450/BU/PS - - - M144/O
MP575/BU/PS - - - M178/O
MP750/BU/PS - - MP750/BU/PS M149/O
MP875/BU/PS - - - M166/O
MP1000/BU MPR1000/VBU/O MP1000/BU MP100/BU-ONLY M47/O
H.P.S. LucaloxCeramalux®Lumalux®
LU35/MED/ECO LU35/MED C35S76/M LU35/MED S76
LU50/ECO LU50 C50S68/ALTO LU50/ECO S68
LU50/MED/ECO LU50/MED C50S68/M LU50/MED S68
LU70/ECO LU70 C70S62/ALTO LU70/D S62
LU70/MED/ECO LU70/MED C70S62/M LU70/MED S62
LU100/ECO LU100/D C100S54/ALTO LU100/D S54
LU100/MED/ECO LU100/MED C100S54/M LU100/MED S54
LU150/ECO LU150/55/D C150S55/M LU150/55/D S55
LU150/100/ECO LU150/100 C150S56/ALTO LU150/100 S56
LU150/MED/ECO LU150/MED C150S55/D/M LU150/55/MED S55
LU150/SBY/LL LU150/55/SBY/XL C150S55/2 LU150/55/SBY S55
LU200/S66/EC0 LU200 C200S66/ALTO LU200/ECO S66
LU250/ECO LU250/D C200S50/ALTO LU250/D S50
LU400/ECO LU400/D C400S51/D/ALTO LU400/D S51
LU400/SBY/LL LU400/SBY/XL C400S51/2 LU400/SBY S51
LU1000/ECO LU1000 C1000S52/ALTO LU1000 S52
Mercury Vapor
MV1000DX HR1000DX36 M36GW-1OOO/DX H36GW-1000/DX H36
MV100DX HM100DX38/MED H38MP-100/DX H38AV-100/DX H38
MV100DX/R40 HR100RDXFL38 H38BP-100/DX H38BP-100/DX H38
MV100DXMOG HR100DX38 H38JA-100/DX H38JA-100/DX H38
MV175CL HR174A39 H39KB-175 H39KB-175 H39
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Cross Reference Guide
109
HID LAMPS
HALCO G.E. PHILIPS OSRAM/SYLVANIA ANSI
Mercury Vapor
MV175DX HR175DX39 H39KC-175/DX H39KC-175/DX H39
MV175DX/R40 HR175RDXFL39 H39BP-175/DX H39BP-175/DX H39
MV250CL HR250A37 H37KB-250 H37KB-250 H37
MV250DX HR250DX37 H37KC250/DX H37KC-250/DX H37
MV400CL HR400A33 H33CD-400 H33CD-400 H33
MV400DX HR400DX33 H33GL-400/DX H33GL-400/DX H33
MV50DX HR40/50DX45-46 H46DL-40-50/DX H45/46DL-40/50/DX H46
MV75DX HR75DX43 H43AV-75/DX H43AV-75/DX H43
– CMH, Multi-Vapor and Lucalox are registered trademarks of General Electric.
– MasterColor and Ceramalux registered trademarks of Philips.
– PowerBall, Metalarc, and Lumalux are registered trademarks of Osram/Sylvania.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
110
General Information and Warning Notices
Metal Halide and Mercury Vapor Lamp Warning:
R WARNING: This lamp can cause serious skin burn and eye inammation from shortwave ultraviolet radiation if outer envelope of the lamp is broken or
punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used.
Lamps that will automatically extinguish when the envelope is broken or punctured are commercially available.
Fixture Requirements-Lamp Enclosure Type
HID lamps have xture requirements that have to be followed. The following codes identify the appropriate xture for a particular lamp.
O = Open or Enclosed Fixtures E = Enclosed Fixtures Only
Use in Enclosed Fixtures
“Enclosed” xture means a xture properly enclosed and designed to contain fragments of hot glass (up to 1100°C) per UL Standard #1598.
If uncertain, contact the xture manufacturer for more details.
Use in Open Fixtures
For lamps operated in the vertical position ±15° that are not designed for “Enclosed Fixtures Only” may be used in either open or enclosed xtures
depending on the environment and application. For instance, if the lamp is positioned by ammable material or in an unoccupied area for extended periods,
an enclosed xture which can contain fragments of hot quartz or glass is recommended.
Protection of Bulbs from Moisture
The outer glass envelope of HID lamps are made of heat-resistant glass, designed to have both strength and thermal-shock-resistant characteristics
appropriate for standard applications in typical luminaries. Nevertheless, it is necessity to provide shielding for lamps to avoid bulb breakage that may
result from direct contact with liquids during operation.
Metal Halide Lamps
Fixture lens/diffuser material must be able to hold fragments of hot glass (up to 1100°C). If you do not know whether or not the xture can safely
withstand an arc tube rupture, contact xture manufacturer. In continuously operating systems (24/7), turn lamps off once per week for 15 minutes.
FAILURE TO DO SO INCREASES THE RISK OF RUPTURE. Fixture should be relamped at or before the lamp’s end of rated life. Light output diminishes
while energy consumption and risk of rupture increase.
High Pressure Sodium Lamps
This is a vacuum jacket and may implode if broken. As a safety measure, wear safety glasses and gloves when installing or removing lamps.
High Pressure Sodium lamps are not position-sensitive and can be operated in any burning position.
Mercury Lamps
Fixture lens/diffuser material must be capable of containing fragments of hot glass (up to 1100°C). If you do not know whether your xture can withstand an
arc tube rupture, contact your xture manufacturer. Relamp xtures at or before the end of rated life; beyond rated life, light output diminishes while energy
consumption and risk of rupture increases. Mercury lamps are not position-sensitive and may be operated in any burning position.
Starting Characteristics
When power is applied, full light does not occur instantaneously, there is a time delay for the lamp to reach 90% total light output.
The delay time for Metal Halide is approximately 2-5 minutes, 3-4 minutes for High Pressure Sodium and 5-7 minutes for Mercury Vapor.
Lumens Listed are Reference Lumens
The rated average lamp lumen is obtained under controlled laboratory conditions in a set burning position.Initial Reference Lumens refer to the lamp lumen
output after burning for 100 hours. Mean Reference Lumens refer to the lamp lumen output at the mean lumen point during lamp life. The mean lumen point
occurs at 50% rated life for HPS and Mercury Vapor lamps, and at 40% rated life for Metal Halide lamps.
Rated Life
Values based on laboratory tests of a large quantity of representative lamps under controlled conditions, including operation at 10 hours per start on ballasts
having specic electrical characteristics. Individual or groups of lamps may vary from the Rated Life given. Lamp operating conditions may also inuence life.
Where Rated Life is less than 24,000 hours, it is a MEDIAN value or life expectancy; the total operating time at which, under normal operating conditions, 50%
of any group of originally installed lamps is expected to be still burning. At burning cycles shorter than 10 hours per start, the median life will shorten as follows:
5 hours start- approximate life of 75% of rating
2 ½ hours start - approximate life of 56% of rating
1 ¼ hours start - approximate life of 42% of rating
HID Color
The color temperature and CRI listed in the tables are for reference purposes only. All HID lamps display some amount of lamp-to-lamp color variation
and shift over life. These characteristics may increase depending on choice of xture, ballast, burning position and ambient conditions. Color difference
may be greater than normal during the rst 100 hours of burning.
HID LAMPS
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 111
Symbols, Footnotes and Abbreviations
HID LAMPS
SYMBOLS
New product introduced within the past year.
$Energy saving product.
XProduct will be discontinued when inventory is depleted.
FOOTNOTES
1Lamps classied as E-type are used ONLY in suitably enclosed luminaries. See lamp warning.
2UV-Stop Quartz ltered design.
3Lamps classied as O-type comply with ANSI standard C78.387 for containment testing and may be used in open luminaries.
See lamp warning.
4When operated on ballasts having a sustaining voltage less than 270 Volts, lamp life may be signicantly reduced.
5Lamps may be operated on ANSI M135 (400W) compliant ballasts.
620,000 average rated life based on 10 hrs/start. 30,000 average rated life based on 12 hrs/start.
7Operates at 360 watts on 400 watt M59 ballast or M165 ballast.
8Horizontally oriented lamps require a position oriented mogul (POM) socket to accept position oriented mogul base.
9H34 and H36 lamps are not interchangeable.
10 Follow xture manufacturer’s recommendations regarding proximity of ballast to lamp.
11 Supply voltage must be held to ±5 volts of rated supply voltage.
12
Color characteristics may vary somewhat from one lamp to another. Time should be allowed for lamp to stabilize in color when
it is turned on for the rst time or if for any reason its operating position is changed. This may require several hours of operation,
with more than one start. Lamp color and output may change temporarily if the lamp is subjected to excess vibration or shock.
Lamp color characteristics may change after long accumulated operating time.
13 Use with 4000 Volt pulse-rated sockets only.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
112
Symbols, Footnotes and Abbreviations
HID LAMPS
FOOTNOTES
14 Performance may not be satisfactory unless operated within specied operating positions.
15 For use in xtures that do not redirect a substantial portion of the energy toward the arc tube; otherwise very early failure
is anticipated.
16
Requires ballast that is designed to operate all popular brands of Metal Halide lamps. 1000W types will operate from H36
conventional lag type ballast for Mercury Vapor lamps at ambient temperatures of 50°F or higher. 1000W types must not
be operated at 1500W or higher.
17 It is a characteristic of phosphor-coated vapor lamps to require a few hundred hours of operation to gradually reach normal
characteristic color. New lamps may have a slight pink appearance during this initial operation period.
18 This product contains less than 120 nCi of Kr-85.
19 For 40W operation use H45 ballast.
20 Rated average life: vertical ±15°. Other positions 75% of rated life.
21 In general, horizontal lumens will be 5-10% lower than the vertical lumen values.
22 Use electrical ballast, peak lead ballast or system that can shut itself off if ballast overheating occurs.
23 Lamp will operate at 400 watts when used on a linear reactor ballast.
24 Do not operate in aviaries or around fowl or small animals.
25
This lamp meets ANSI specications for T6 tube size as dened by ANSI C78.43-2007; nominal diameter for this item
is 0.75” with a maximum diameter of 1”. Halco 150W lamps have an outer glass diameter of 0.87” to increase arc tube
reliability. Please ensure xture dimensions prior to ordering.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 113
Symbols, Footnotes and Abbreviations
HID LAMPS
ABBREVIATIONS
/3K Sufx used to indicate Color Temperature of 3500K.
/4K Sufx used to indicate Color Temperature of 4000K or 4200K.
/10K Sufx used to indicate Color Temperature of 10,000K.
/BDX Sufx used to indicate a Blue ProLume® Metal Halide lamp.
BU Code abbreviation for Base Up Operating lamps.
CCode abbreviation for lamps with a Coated nish.
CDM Code abbreviation for Ceramic Metal Halide.
CL Code abbreviation for lamps with a Clear nish.
/CS Sufx used to indicate CoverShield® safety coated lamps.
/CSTF Sufx used to indicate CoverShield® safety coated lamps.
/D Sufx used to indicate Diffused lamps.
DE Code abbreviation for Double Ended Metal Halide lamps.
DX Code abbreviation for ProLume® Deluxe White Mercury Vapor lamps.
/ES Sufx used to indicate an Energy Saving Metal Halide lamp.
/FL Sufx used to indicate Flood lamps.
/GDX Sufx used to indicate a Green ProLume® Metal Halide lamp.
/HBU Sufx used to indicate Horizontal to Base Up Metal Halide lamps.
/HOR Sufx used to indicate Horizontal Metal Halide lamps.
/LL Sufx used to indicate lamps with a Long Life.
LU Code abbreviation for High Pressure Sodium lamps.
/LU Sufx used to indicate High Pressure Sodium to Metal Halide retrot lamp.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
114
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
/M Sufx used to indicate Major brand HID lamps (GE, Philips, Osram/Sylvania).
/MDX Sufx used to indicate a Magenta ProLume® Metal Halide lamp.
MED Code abbreviation for Medium base type (E26/27).
MH Code abbreviation for Metal Halide lamps.
MHC Code abbreviation for Ceramic Metal Halide lamps.
MV Code abbreviation for Mercury Vapor lamps.
/MOG Sufx used to indicate a Mogul base lamp.
MP Code abbreviation for Protected Metal Halide lamps suitable for open xture applications.
NC Sufx used to indicate Non-Cycling High Pressure Sodium lamps.
NFL Code abbreviation for Narrow Flood lamps.
/SBY Sufx used to indicate Stand-By Twin Arc Tube lamps.
SE Code abbreviation for Single Ended Metal Halide lamps.
/SP Sufx used to indicate Spot lamps.
TC Code abbreviation for T4 CDM lamps.
UCode abbreviation for Universal Metal Halide lamps.
/UVS Sufx used to indicate UV-Stop lamps.
HID LAMPS
TOC
HALOGEN LAMPS
CONTENTS
118
119
121
121
121
122
126
127
128
130
131
How to Read a Table
PAR Lamps
A19 Lamps
Aluminum Reector Lamps
Double Envelope Lamps
MR8, MR11, MR16 Lamps
JC Type Lamps
J Type Double Ended Lamps
JD Type Single Ended Lamps
Bulb, Base and Filament Identication
Symbols, Footnotes and Abbreviations
®
main
TOC
HOW TO READ A HALOGEN LAMP TABLE
BULB
Designations indicate shape and size.
Illustrations can be found on page 130
and at the top of each page.
BASE
Indicates base type.
Full base descriptions
and illustrations can be
found on page 130.
PACKAGE QUANTITY
Indicates minimum sell quantity
and smallest shipping carton.
VOLTS
Indicate the
product’s
design voltage
of operation.
DESIGN
FILAMENT
Filament types are
illustrated on
page 130.
PRODUCT CODE
Abbreviated product description
can also be used for ordering.
A key to abbreviations can be
found on page 132.
WATTS
Indicates the
power consumed
by the lamp during
operation.
PRODUCT
NUMBER
Use this number when
placing an order. BEAM
SPREAD
Indicates the
beam angle or
beam spread
of a bulb,
measured in
degrees.
FOOTNOTES &
SYMBOLS
Related footnotes can
be found on page 131.
LUMENS
Represents
the average
light output.
DESCRIPTION
Bulb nish and other
important information.
MOL
Indicates
maximum
overall length
in inches.
& JC Type
5 WATT
T3 G4 107006 3 JC5 Clear 10/1000 12 60 2800 3000 C-8 1.18” -
10 WATT
T3 BA15s 147008 3 JC10/BA15S Clear 10/1000 12 120 2800 3000 C-8 1.50” -
107944 2,3 JC10/BA15S/HX Clear HaloXen®10/1000 12 120 2850 10000 C-8 1.50” -
G4 107008 3 JC10 Clear 10/1000 12 120 2800 3000 C-8 1.18” -
107710 2,3 JC10/HX Clear HaloXen®10/1000 12 120 2850 10000 C-8 1.18” -
90002 3 JC10/X Clear Xenon 10/500 12 120 2700 20000 C-8 1.18” -
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. Volts Lumens CBCP Avg.
Life
Design
Filament MOL Beam
Spread
AVERAGE
LIFE
Average rated life
expressed in hours.
CBCP
The luminous
intensity at the center
of the beam of a
reector lamp.
TOC
119
HALOGEN LAMPS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Means this lamp meets Federal Minimum Efciency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.
E
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. Volts Lumens CBCP Avg.
Life
Design
Filament MOL Beam
Spread
PAR36 PAR20PAR38 PAR16
PAR30
PAR30L
, , & PAR Lamps
20 WATT
PAR36 MP-
Term.
70304 X $ 1,7 HP36WFL20/24V Wide Flood 1/12 24 240 480 5000 CC-6 2.75” 32°
107788 $ 1,2,7 HP36NSP20/HX Narrow Spot HaloXen®1/12 12 260 1900 5000 C-6 2.75” 12°
107790 $ 1,2,7 HP36VNSP20/HX Very Narrow Spot
HaloXen®1/12 12 260 9000 5000 C-6 2.75” 5°
107792 $ 1,2,7 HP36WFL20/HX Wide Flood HaloXen®1/12 12 260 530 5000 C-6 2.75” 32°
35 WATT
PAR20 Med. 107610 N $ 1,7,8 HP20NFL35 Narrow Flood 15 130 450 700 3000 CC-8 3.07” 30°
PAR36 MP-
Term.
107794 $ 1,2,7 HP36NSP35/HX Narrow Spot HaloXen®1/12 12 540 3500 5000 C-6 2.75” 12°
107796 $ 1,2,7 HP36VNSP35/HX Very Narrow Spot
HaloXen®1/12 12 540 17000 5000 C-6 2.75” 5°
107798 $ 1,2,7 HP36WFL35/HX Wide Flood HaloXen®1/12 12 540 1000 5000 C-6 2.75” 32°
70306 $ 1,2,7 HP36WFL35/24V Wide Flood 1/12 24 500 960 5000 CC-6 2.75” 32°
39 WATT
PAR20 Med. 70343 $ 1,2,7 HP20NFL39/HX Narrow Flood HaloXen®1/15 120 530 900 2000 CC-8 3.23" 30°
70354 $ 1,2,7 HP20NFL39/HX/130 Narrow Flood HaloXen®1/15 130 530 900 2000 CC-8 3.23” 30°
PAR30 Med. 70347 $ 1,2,7 HP30FL39/HX Flood HaloXen®1/15 120 530 1100 2000 CC-8 3.62" 30°
70353 $ 1,2,7 HP30FL39/HX/130 Flood HaloXen®1/15 130 530 1100 2000 CC-8 3.62” 30°
PAR30L Med. 70344 $ 1,2,7 HP30FL39L/HX Flood HaloXen®1/15 120 530 1000 2000 CC-8 4.75" 36°
70204 $ 1,2,7 HP30WFL39L/HX Wide Flood HaloXen®1/15 120 530 650 2000 CC-8 4.75" 50°
70203 $ 1,2,7 HP30SP39L/HX Spot HaloXen®1/15 120 530 4000 2000 CC-8 4.75" 15°
70356 $ 1,2,7 HP30FL39L/HX/130 Flood HaloXen®1/15 130 530 4000 2000 CC-8 4.75” 36°
PAR38 Med. 70340 $ 1,2,7 HP38FL39/HX Flood HaloXen®1/15 120 530 1000 2000 CC-8 5.31” 30°
70404 $ 1,2,7 HP38SP39/HX Spot HaloXen®1/15 120 530 5000 2000 CC-8 5.31" 10°
70355 $ 1,2,7 HP38FL39/HX/130 Flood HaloXen®1/15 130 530 1100 2000 CC-8 5.31” 30°
45 WATT
PAR16 Med. 107502 N $ 1,7,8 HP16NFL45 Narrow Flood 15 130 450 850 3000 CC-2V 3.07” 30°
50 WATT
PAR36 MP-
Term.
107782 1,2,7 HP36NSP50/HX Narrow Spot HaloXen®1/12 12 910 5000 5000 C-6 2.75” 12°
107784 1,2,7 HP36VNSP50/HX Very Narrow Spot
HaloXen®1/12 12 910 25000 5000 C-6 2.75” 5°
107786 1,2,7 HP36WFL50/HX Wide Flood HaloXen®1/12 12 910 1500 5000 C-6 2.75” 32°
PAR38 Med. 70350 1,2,7 HP38FL50/S/HX Silver PAR Flood HaloXen®1/15 120 920 1300 1500 CC-8 5.31” 30°
53 WATT
PAR30 Med. 70310 $ 1,2,7 HP30FL53/XIR Flood XIR® 1/15 120 1050 2500 3500 CC-8 3.62” 30°
PAR30L Med. 70311 $ 1,2,7 HP30FL53L/XIR Flood XIR® 1/15 120 930 2500 3500 CC-8 4.75” 30°
PAR38 Med. 70312 $ 1,2,7 HP38FL53/XIR Flood XIR® 1/15 120 960 4100 3500 CC-8 5.31” 25°
E
E
E
E
TOC
120
HALOGEN LAMPS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. Volts Lumens CBCP Avg.
Life
Design
Filament MOL Beam
Spread
PAR56
PAR64
PAR38
PAR30
PAR30L
PAR16
BR30
BR38
BR40
, , & PAR Lamps continued
60 WATT
PAR16 Med. 107616 N $1,7,8 HP16NFL60 Narrow Flood 15 130 550 1500 3000 CC-8 3.07” 30°
107850 N $1,7,8 HP16NFL60/120 Narrow Flood 15 120 550 1500 3000 CC-8 3.07” 30°
107504 N $1,7,8 HP16NSP60 Narrow Spot 15 130 550 4000 3000 CC-8 3.07” 10°
PAR30 Med. 70345 $ 1,2,7 HP30FL60/S/HX Silver PAR Flood HaloXen®1/15 120 1090 2300 1500 CC-8 3.62” 30°
PAR30L Med. 70342 $ 1,2,7 HP30FL60L/S/HX Silver PAR Flood HaloXen®1/15 120 1090 1900 1500 CC-8 4.75” 36°
70349 $ 1,2,7 HP30WFL60L/S/HX Silver PAR Wide
Flood HaloXen®1/15 120 1090 1200 1500 CC-8 4.75” 50°
70348 $ 1,2,7 HP30SP60L/S/HX Silver PAR Spot HaloXen®1/15 120 1090 5800 1500 CC-8 4.75” 15°
PAR38 Med. 70341 $ 1,2,7 HP38FL60/S/HX Silver PAR Flood HaloXen®1/15 120 1090 2000 1500 CC-8 5.31” 30°
65 WATT
BR30 Med. 75009 1,7 BR30FL65/H Flood 24 120 750 -2500 CC-8 5.37” -
BR40 Med. 75010 1,7 BR40FL65/H Flood 24 120 750 -2500 CC-8 6.56” -
70 WATT
PAR38 Med. 70346 $ 1,2,7 HP38FL70/S/HX Silver PAR Flood HaloXen®1/15 120 1350 2800 1500 CC-8 5.31” 30°
70352 $ 1,2,7 HP38SP70/S/HX Silver PAR Spot HaloXen®1/15 120 1350 7200 1500 CC-8 5.31” 10°
80 WATT
PAR38 Med. 70351 $ 1,2,7 HP38FL80/S/HX Silver PAR Flood HaloXen®1/15 120 1580 3000 1500 CC-8 5.31” 30°
250 WATT
PAR38 Med. 15558 N 1,5,7 Q250PAR/FL Flood Major 1/6 120 3600 9000 4500 CC-8 5.32” 30°
15526 N 1,5,7 Q250PAR/SP Spot Major 1/6 120 3600 40000 4500 CC-8 5.32” 10°
500 WATT
PAR56 End
Prg.
65044 1,5,6,7 PAR56MFL500Q Medium Flood 1/12 120 8000 43000 3000 CC-6 5.00” 30x11
65043 1,5,6,7 PAR56NSP500Q Narrow Spot 1/12 120 8000 73500 3000 CC-6 5.00” 15x8
65045 1,5,6,7 PAR56WFL500Q Wide Flood 1/12 120 8000 19000 3000 CC-6 5.00” 45x20
E
E
E
E
E
E
E
E
Means this lamp meets Federal Minimum Efciency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.
E
TOC
121
HALOGEN LAMPS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. Volts Lumens CBCP Avg.
Life
Design
Filament MOL Beam
Spread
AR111A19 BT15
A19 Lamps
29 WATT
A19 Med. 76005 $ A19CL29/H Clear 12/120 120 430 -1000 CC-8 4.25” -
76001 $ A19SW29/H Soft White 12/120 120 430 -1000 CC-8 4.25” -
43 WATT
A19 Med. 76006 $ A19CL43/H Clear 12/120 120 750 -1000 CC-8 4.25” -
76004 $ A19SW43/H Soft White 12/120 120 750 -1000 CC-8 4.25” -
53 WATT
A19 Med. 76007 $ A19CL53/H Clear 12/120 120 1050 -1000 CC-8 4.25” -
76002 $ A19SW53/H Soft White 12/120 120 1050 -1000 CC-8 4.25” -
72 WATT
A19 Med. 76000 $ A19CL72/H Clear 12/120 120 1490 -1000 CC-8 4.25” -
76003 $ A19SW72/H Soft White 12/120 120 1490 -1000 CC-8 4.25” -
Aluminum Reector
50 WATT
AR111 G53 104150 3 AR111FL50 Flood 1/6 12 -4100 3000 C-8 2.64” 24°
104154 3 AR111SP50 Spot 1/6 12 -23000 3000 C-8 2.64” 8°
104158 3 AR111WFL50 Wide Flood 1/6 12 -1200 3000 C-8 2.64” 45°
75 WATT
AR111 G53 104152 3 AR111FL75 Flood 1/6 12 -5300 3000 C-8 2.64” 24°
104156 3 AR111SP75 Spot 1/6 12 -30000 3000 C-8 2.64” 8°
104160 3 AR111WFL75 Wide Flood 1/6 12 -1700 3000 C-8 2.64” 45°
Double Envelope
60 WATT
BT15 Med. 107052 N, 4 JTT60/SW Soft White 10/200 120 820 -2500 CC-8 4.61” -
75 WATT
BT15 Med. 107048 N, 4 JTT75/SW Soft White 10/200 120 1000 -2500 CC-8 4.61” -
E
E
E
E
E
E
E
E
Means this lamp meets Federal Minimum Efciency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.
E
TOC
122
HALOGEN LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. Volts CBCP Color
Temp
Avg.
Life
Design
Filament MOL Beam
Spread
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Means this lamp meets Federal Minimum Efciency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.
E
MR16
GU5.3
MR11
BA15d
MR11
GU4
MR8
GU4
MR11
GU10
& MR8, MR11 & MR16
5 WATT
MR11 GU4 107516 3 MR11FL5/L Flood w/Lens 10/200 12 80 2950 2000 C-6 1.38” 30°
10 WATT
MR8 GU4 107488 3 MR8W10/L Wide Flood w/Lens 10/200 12 300 3000 2000 C-8 1.30” 20°
MR11 GU4 107940 3 MR11FL10/L Flood w/Lens 10/200 12 300 2900 2000 C-6 1.38” 30°
107114 3 MR11SP10/L Spot w/Lens 10/200 12 2500 2900 2000 C-6 1.38” 10°
MR16 GU5.3 107098 3 MR16FL10 Flood 10/100 12 340 2900 3000 C-6 1.77” 36°
107097 3 MR16FL10/L Flood w/Lens 10/100 12 200 2900 2000 C-6 1.77” 36°
107094 3 MR16SP10/L Spot w/Lens 10/100 12 2000 2900 2000 C-6 1.77” 12°
16 WATT
MR16 GU5.3 70754 X $ 2,3 MR16SP20/L/16HX Spot w/Lens HaloXen®10/100 12 3600 3100 5000 C-8 1.77” 10°
70753 X $ 2,3 MR16NFL20/L/16HX Narrow Flood w/Lens
HaloXen®10/100 12 1100 3100 5000 C-8 1.77” 25°
70752 $ 2,3 MR16FL20/L/16HX Flood w/Lens HaloXen®10/100 12 650 3100 5000 C-8 1.87” 36°
70755 X $ 2,3 MR16WFL20/L/16HX Wide Flood w/Lens
HaloXen®10/100 12 400 3100 5000 C-8 1.77” 60°
20 WATT
MR8 GU4 107466 3 MR8N20/L Narrow Flood w/Lens 10/200 12 1750 3000 2000 C-8 1.30” 10°
108610 3 MR8W20/L Wide Flood w/Lens 10/200 12 900 3000 2000 C-8 1.30” 20°
MR11 BA15d 107101 3 MR11FTB/L/TL Narrow Spot w/Lens
Twist Lock 10/200 12 5500 2900 3000 C-6 1.77” 10°
107103 3 MR11FTC/L/TL Medium Flood w/Lens
Twist Lock 10/200 12 1750 2900 3000 C-6 1.77” 20°
107105 3 MR11FTD/L/TL Flood w/Lens Twist Lock 10/200 12 700 2900 3000 C-6 1.77” 30°
GU4 107100 3 MR11FTB/L Narrow Spot w/Lens 10/200 12 5500 2900 3000 C-6 1.38” 10°
107922 X 2,3 MR11FTB/L/HX Narrow Flood w/Lens
HaloXen®10/200 12 4100 3100 10000 C-8 1.38” 10°
107472 X 3 MR11FTB/L/24V Narrow Spot w/Lens 10/200 24 2800 2900 3000 CC-6 1.38” 10°
107102 3 MR11FTC/L Medium Flood w/Lens 10/200 12 1750 2900 3000 C-6 1.38” 20°
107924 X 2,3 MR11FTC/L/HX Medium Flood w/Lens
HaloXen®10/200 12 1750 3100 10000 C-8 1.38” 20°
107474 X,3 MR11FTC/L/24V Medium Flood w/Lens 10/200 24 1000 2900 3000 CC-6 1.38” 20°
107104 3 MR11FTD/L Flood w/Lens 10/200 12 700 2900 3000 C-6 1.38” 30°
107926 2,3 MR11FTD/L/HX Flood w/Lens HaloXen®10/200 12 700 3100 10000 C-8 1.38” 30°
GU10 107544 3 MR11FL20/L/GU10 Flood w/Lens 10/200 120 220 3000 2000 CC-2V 1.38” 30°
MR16 GU5.3 107480 3 MR16BAB Flood 10/100 12 460 2900 3000 C-8 1.77” 38°
107120 3 MR16BAB/SC Flood SureColor®10/100 12 700 2950 5000 C-8 1.77” 38°
107494 3 MR16BAB/L Flood w/Lens 10/100 12 450 2900 3000 C-8 1.77” 38°
107121 3 MR16BAB/L/SC Flood w/Lens SureColor®10/100 12 700 2950 5000 C-8 1.77” 38°
107526 2,3 MR16BAB/L/HX Flood w/Lens HaloXen®10/100 12 700 3100 10000 C-8 1.87” 36°
TOC
123
HALOGEN LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. Volts CBCP Color
Temp
Avg.
Life
Design
Filament MOL Beam
Spread
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Means this lamp meets Federal Minimum Efciency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.
E
MR16
GU5.3
MR11
GU4
MR16
GU10
& MR8, MR11 & MR16 continued
20 WATT continued
MR16 GU5.3 70700 3MR16BAB/L/AL Flood w/Lens 10/100 12 650 2950 5000 C-8 1.77” 36°
70710 3MR16BAB/L/AL/24V Flood w/Lens 10/100 24 650 2950 5000 CC-8 1.77” 38°
107300 X 3 MR16BAB/FR/SC Frosted Flood w/Lens
SureColor®10/100 12 450 2950 5000 C-8 1.77” 38°
107350 3 MR16BAB/BLK/L Flood Black Back w/Lens 10/100 12 900 2950 5000 C-8 1.87” 38°
107115 3 MR16BAB/BLU Blue Flood 10/100 12 850 -3000 C-6 1.77” 38°
107116 3 MR16BAB/GRN Green Flood 10/100 12 850 -3000 C-6 1.77” 38°
107118 3 MR16BAB/RED Red Flood 10/100 12 850 -3000 C-6 1.77” 38°
107440 3 MR16BBF/L/SC Medium Flood w/Lens
SureColor®10/100 12 1500 2950 5000 C-8 1.77” 20°
107482 3 MR16ESX Narrow Spot 10/100 12 3350 2900 3000 C-8 1.77” 12°
107122 3 MR16ESX/SC Narrow Spot SureColor®10/100 12 4000 2950 5000 C-8 1.77” 10°
107496 3 MR16ESX/L Narrow Spot w/Lens 10/100 12 3280 2900 3000 C-8 1.77” 12°
107123 3 MR16ESX/L/SC Narrow Spot w/Lens
SureColor®10/100 12 4000 2950 5000 C-8 1.87” 10°
107932 X 2,3 MR16ESX/L/HX Narrow Spot w/Lens
HaloXen®10/100 12 4100 3100 10000 C-8 1.77” 10°
107090 3 MR16WFL20/SC Wide Flood SureColor®10/100 12 450 2950 5000 C-8 1.77” 60°
107400 3 MR16WFL20/L/SC Wide Flood w/Lens
SureColor®10/100 12 450 2950 5000 C-8 1.77” 60°
107942 2,3 MR16WFL20/L/HX Wide Flood w/Lens
HaloXen®10/100 12 400 3100 10000 C-8 1.77” 60°
70702 3MR16WFL20/L/AL Wide Flood w/Lens 10/100 12 400 2950 5000 C-8 1.77” 60°
70716 X 3 MR16WFL20/L/AL/24V Wide Flood w/Lens 10/100 24 400 2950 5000 CC-8 1.77” 60°
GU10 107152 3 MR16FL20/L/GU10 Flood w/Lens 10/200 120 170 2800 2000 CC-2V 2.16” 30°
26 WATT
MR16 GU5.3 70758 X $ 2,3 MR16SP35/L/26HX Spot w/Lens HaloXen®10/100 12 6500 3100 5000 C-8 1.77” 10°
70757 X $ 2,3 MR16NFL35/L/26HX Narrow Flood w/Lens
HaloXen®10/100 12 3150 3100 5000 C-8 1.77” 25°
70756 $ 2,3 MR16FL35/L/26HX Flood w/Lens HaloXen®10/100 12 1250 3100 5000 C-8 1.77” 36°
70759 X $ 2,3 MR16WFL35/L/26HX Wide Flood w/Lens
HaloXen®10/100 12 800 3100 5000 C-8 1.77” 60°
35 WATT
MR11 BA15d 107454 X 3 MR11FTE/L/TL Narrow Spot w/Lens
Twist Lock 10/200 12 4600 2900 3000 C-6 1.77” 10°
107456 3 MR11FTF/L/TL Medium Flood w/Lens
Twist Lock 10/200 12 2400 2900 3000 C-6 1.65” 20°
GU4 107106 3 MR11FTE/L Narrow Spot w/Lens 10/200 12 4600 2900 3000 C-6 1.38” 10°
107108 3 MR11FTF/L Medium Flood w/Lens 10/200 12 2400 2900 3000 C-6 1.38” 20°
107928 X 2,3 MR11FTF/L/HX Medium Flood w/Lens
HaloXen®10/200 12 3000 3100 10000 C-8 1.38” 20°
TOC
124
HALOGEN LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. Volts CBCP Color
Temp
Avg.
Life
Design
Filament MOL Beam
Spread
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Means this lamp meets Federal Minimum Efciency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.
E
MR16
GU5.3
MR11
GU10
MR11
GU4
& MR8, MR11 & MR16 continued
35 WATT continued
MR11 GU4 107110 3 MR11FTH/L Flood w/Lens 10/200 12 1500 2900 3000 C-6 1.38” 30°
GU10 107546 3 MR11FL35/L/GU10 Flood w/Lens 10/100 120 560 2850 2000 CC-2V 1.38” 30°
MR16 GU5.3 107141 3 MR16FRA/L/SC Narrow Flood w/Lens
SureColor®10/100 12 3000 3000 5000 C-8 1.77” 20°
107938 2,3 MR16FRA/L/HX Narrow Flood w/Lens
HaloXen®10/100 12 3500 3100 10000 C-8 1.87” 20°
107136 3 MR16FRB/SC Spot SureColor®10/100 12 8000 3000 5000 C-8 1.77” 10°
107420 3 MR16FRB/L/SC Spot w/Lens SureColor®10/100 12 8000 3000 5000 C-8 1.77” 10°
107446 X 3 MR16FRB/24V Spot 10/100 24 5000 3000 4000 CC-6 1.77” 12°
107492 3 MR16FMW Flood 10/100 12 950 3000 3000 C-8 1.77” 36°
107138 3 MR16FMW/SC Flood SureColor®10/100 12 1500 3000 5000 C-8 1.77” 38°
107508 3 MR16FMW/L Flood w/Lens 10/100 12 880 3000 3000 C-8 1.77” 36°
107139 3 MR16FMW/L/SC Flood w/Lens SureColor®10/100 12 1500 3000 5000 C-8 1.77” 38°
107518 2,3 MR16FMW/L/HX Flood w/Lens HaloXen®10/100 12 1250 3100 10000 C-8 1.77” 38°
70704 3MR16FMW/L/AL Flood w/Lens 10/100 12 1300 3000 5000 C-8 1.77” 36°
70714 3MR16FMW/L/AL/24V Flood w/Lens 10/100 24 1300 3000 5000 CC-8 1.77” 38°
107362 3 MR16FMW/BLK/L Flood Black Back w/Lens 10/100 12 1700 3000 5000 C-6 1.77” 36°
107092 3 MR16WFL35/SC Wide Flood SureColor®10/100 12 800 3000 5000 C-8 1.77” 60°
107430 3 MR16WFL35/L/SC Wide Flood w/Lens
SureColor®10/100 12 800 3000 5000 C-8 1.77” 60°
70720 2,3 MR16WFL35/L/HX Wide Flood w/Lens
HaloXen®10/100 12 750 3100 10000 C-8 1.77” 60°
70706 3MR16WFL35/L/AL Wide Flood w/Lens 10/100 12 700 3000 5000 C-8 1.77” 60°
70718 3MR16WFL35/L/AL/24V Wide Flood w/Lens 10/100 24 700 3000 5000 CC-8 1.77” 60°
GU10 107154 3 MR16FL35/L/GU10 Flood w/Lens 10/100 120 900 2800 2000 CC-2V 2.16” 30°
37 WATT
MR16 GU5.3 70737 $ 2,3 MR16NFL50/L/37HX Narrow Flood w/Lens
HaloXen®10/100 12 4400 3100 5000 C-8 1.87” 25°
70736 $ 2,3 MR16FL50/L/37HX Flood w/Lens HaloXen®10/100 12 2200 3100 5000 C-8 1.87” 36°
50 WATT
MR16 GU5.3 107484 3 MR16EXN Flood 10/100 12 1350 2900 3000 C-8 1.77” 36°
107124 3 MR16EXN/SC Flood SureColor®10/100 12 2000 3050 5000 C-8 1.77” 38°
107498 3 MR16EXN/L Flood w/Lens 10/100 12 1350 2900 3000 C-8 1.77” 36°
107125 3 MR16EXN/L/SC Flood w/Lens SureColor®10/100 12 2000 3050 5000 C-8 1.77” 38°
107514 2,3 MR16EXN/L/HX Flood w/Lens HaloXen®10/100 12 1700 3150 10000 C-8 1.87” 38°
70708 3MR16EXN/L/AL Flood w/Lens 10/100 12 1900 2900 5000 C-8 1.77” 36°
107304 X,3 MR16EXN/FR/SC Flood Frost w/Lens
SureColor®10/100 12 1050 3050 5000 C-8 1.77” 38°
107452 3 MR16EXN/24V Flood 10/100 24 1600 2900 4000 CC-6 1.77” 36°
107356 3 MR16EXN/BLK/L Flood Black Back w/Lens 10/100 12 2200 3050 5000 C-8 1.77” 36°
107358 3 MR16EXN/SIL/L Flood Silver Back w/Lens 10/100 12 2200 3050 5000 C-8 1.77” 36°
TOC
125
HALOGEN LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. Volts CBCP Color
Temp
Avg.
Life
Design
Filament MOL Beam
Spread
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Means this lamp meets Federal Minimum Efciency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.
E
JDR
Med.
MR16
GU10
& MR8, MR11 & MR16 continued
50 WATT continued
MR16 GU5.3 107172 3 MR16EXN/BLU Blue Flood 10/100 12 1350 -3000 C-8 1.77” 36°
107174 3 MR16EXN/GRN Green Flood 10/100 12 1350 -3000 C-8 1.77” 36°
107170 3 MR16EXN/RED Red Flood 10/100 12 1350 -3000 C-8 1.77” 36°
107176 3 MR16EXN/YEL Yellow Flood 10/100 12 1350 -3000 C-8 1.77” 36°
107486 3 MR16EXT Spot 10/100 12 11000 2900 3000 C-8 1.77” 12°
107126 3 MR16EXT/SC Spot SureColor®10/100 12 10000 3050 5000 C-8 1.77” 10°
107500 3 MR16EXT/L Spot w/Lens 10/100 12 10700 2900 3000 C-8 1.77” 12°
107127 3 MR16EXT/L/SC Spot w/Lens SureColor®10/100 12 10000 3050 5000 C-8 1.77” 10°
107934 2,3 MR16EXT/L/HX Spot w/Lens HaloXen®10/100 12 10000 3150 10000 C-8 1.77” 12°
107490 3 MR16EXZ Narrow Flood 10/100 12 3000 2900 3000 C-8 1.77” 24°
107128 3 MR16EXZ/SC Narrow Flood SureColor®10/100 12 4000 3050 5000 C-8 1.77” 20°
107464 X,3 MR16EXZ/U Narrow Flood 10/100 12 3500 3150 12000 C-8 1.77” 20°
107506 3 MR16EXZ/L Narrow Flood w/Lens 10/100 12 2940 2900 3000 C-8 1.77” 24°
107129 3 MR16EXZ/L/SC Narrow Flood w/Lens
SureColor®10/100 12 4000 3050 5000 C-8 1.77” 20°
107936 2,3 MR16EXZ/L/HX Narrow Flood w/Lens
HaloXen®10/100 12 4400 3150 10000 C-8 1.87” 24°
107146 3 MR16FNV/SC Wide Flood SureColor®10/100 12 1050 3050 5000 C-8 1.77” 60°
107462 X,3 MR16FNV/U Wide Flood 10/100 12 750 3050 12000 C-8 1.77” 60°
107410 3 MR16FNV/L/SC Wide Flood w/Lens
SureColor®10/100 12 1050 3050 5000 C-8 1.77” 60°
107524 2,3 MR16FNV/L/HX Wide Flood w/Lens
HaloXen®10/100 12 1000 3150 10000 C-8 1.87” 60°
G8 108510 3 MR16EXN/G8 Flood 10/100 120 1350 2900 2000 CC-2V 1.77” 36°
GU10 107180 3 MR16FL50/L/GU10 Flood w/Lens 10/100 120 1500 2900 2000 CC-2V 2.16” 30°
57 WATT
MR16 GU5.3 70760 $ 2,3 MR16FL75/L/57HX Flood w/Lens HaloXen®10/100 12 2400 3100 5000 C-8 1.87” 36°
75 WATT
MR16 GU5.3 107130 3 MR16EYC/SC Flood SureColor®10/100 12 2750 3100 5000 C-8 1.77” 38°
107132 3 MR16EYF/SC Spot SureColor®10/100 12 13000 3100 5000 C-8 1.77” 10°
107134 3 MR16EYJ/SC Narrow Flood
SureColor®10/100 12 6000 3100 5000 C-8 1.77” 20°
107312 3 MR16WFL75/SC Wide Flood SureColor®10/100 12 1400 3100 5000 C-8 1.77” 60°
107314 3 MR16WFL75/L/SC Wide Flood w/Lens
SureColor®10/100 12 1400 3100 5000 C-8 1.77” 60°
JDR Int. 107056 N,3 JDR75INT/L Wide Flood w/Lens 10/200 130 1600 2950 2000 CC-2V 3.15” 30°
Med. 107054 N,3 JDR75/L Wide Flood w/Lens 10/200 130 1600 2950 2000 CC-2V 3.15” 30°
MR16
GU5.3/G8
JDR
Int.
TOC
126
HALOGEN LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. Volts Lumens Color
Temp
Avg.
Life
Design
Filament MOL Beam
Spread
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Means this lamp meets Federal Minimum Efciency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.
E
JC
G4
GY6.35
G8
JC
BA15d
JC/
JCD
G6.35
JC
G9
& JC Type
5 WATT
T3 G4 107006 3 JC5 Clear 10/1000 12 60 2800 3000 C-8 1.18” -
10 WATT
T3 BA15s 147008 3 JC10/BA15S Clear 10/1000 12 120 2800 3000 C-8 1.50” -
107944 2,3 JC10/BA15S/HX Clear HaloXen®10/1000 12 120 2850 10000 C-8 1.50” -
G4 107008 3 JC10 Clear 10/1000 12 120 2800 3000 C-8 1.18” -
107710 2,3 JC10/HX Clear HaloXen®10/1000 12 120 2850 10000 C-8 1.18” -
90002 3 JC10/X Clear Xenon 10/500 12 120 2700 20000 C-8 1.18” -
20 WATT
T3 BA15s 147010 3 JC20/BA15S Clear 10/1000 12 300 2800 3000 C-8 1.50” -
107718 2,3 JC20/BA15S/HX Clear HaloXen®10/1000 12 350 2900 10000 C-8 1.50” -
G4 107010 3 JC20 Clear 10/1000 12 300 2800 3000 C-8 1.18” -
107712 2,3 JC20/HX Clear HaloXen®10/1000 12 350 2900 10000 C-8 1.18” -
70922 2,3 JC20/24V/HX Clear HaloXen®10/1000 24 350 4100 5000 CC-6 1.25” -
90003 3 JC20/X Clear Xenon 10/500 12 250 2700 10000 C-8 1.18” -
T4 G6.35 107009 3 JC20/6.35 Clear 10/1000 12 300 2800 3000 C-8 1.65” -
GY6.35 107036 3 JCD20 Clear 10/500 130 180 2750 2000 CC-2 1.69” -
G8 107076 3 JCD20/G8 Clear 10/500 130 180 2750 2000 CC-2 1.69” -
25 WATT
T4 G9 71001 3 JCD25/G9 Clear 10/500 130 280 2650 2000 CC-2V 1.69” -
107902 3 JCD25FR/G9 Frost 10/500 130 280 2650 2000 CC-2V 1.69” -
35 WATT
T4 BA15d 147012 3 JC35/BA15D Clear 10/1000 12 600 2850 3000 C-8 1.65” -
107720 X 3 JC35/BA15D/HX Clear HaloXen®10/1000 12 600 2900 10000 C-8 1.50” -
G4 107000 3 JC35/G4 Clear 10/1000 12 600 2850 3000 C-8 1.58” -
G6.35 107012 3 JC35 Clear 10/1000 12 600 2850 3000 C-8 1.58” -
107714 2,3 JC35/HX Clear HaloXen®10/1000 12 600 2900 10000 C-8 1.60” -
GY6.35 107011 3 JCD35 Clear 10/500 130 350 2800 2000 CC-2V 1.81” -
G8 107072 3 JCD35/G8 Clear 10/500 130 350 2800 2000 CC-2V 1.69” -
40 WATT
T4 G9 107906 3 JCD40/G9 Clear 10/500 130 480 2750 2000 CC-2V 1.69” -
107908 3 JCD40/FR/G9 Frost 10/500 130 450 2750 2000 CC-2V 1.69” -
107310 3 JCD40/FR/G9/120 Frost 10/1000 120 450 2800 2000 CC-2V 1.69” -
JC
BA15s
TOC
127
HALOGEN LAMPS
Bulb Base Product
Number Footnotes Product
Code Description Pkg.
Qty. Volts Lumens Color
Temp
Avg.
Life
Design
Filament MOL Beam
Spread
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Means this lamp meets Federal Minimum Efciency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.
E
& JC Type continued
50 WATT
T4 G6.35 107014 3 JC50 Clear 10/1000 12 900 2950 3000 C-8 1.65” -
107716 2,3 JC50/HX Clear HaloXen®10/1000 12 900 3000 10000 C-8 1.60” -
GY6.35 107015 3 JCD50 Clear 10/500 130 600 2900 2000 CC-2 1.69” -
G8 107074 3 JCD50/G8 Clear 10/500 130 600 2900 2000 CC-2 1.69” -
60 WATT
T4 G9 71002 3 JCD60/G9 Clear 10/500 130 780 2950 2000 CC-2V 1.69” -
107904 3 JCD60FR/G9 Frost 10/500 130 750 2950 2000 CC-2V 1.69” -
75 WATT
T4 GY6.35 107002 3 JC75 Clear 10/1000 12 1350 3000 3000 C-8 1.69” -
107001 3 JCD75 Clear 10/500 130 980 2950 2000 CC-2V 1.69” -
100 WATT
T4 GY6.35 107004 3 JC100 Clear 10/1000 12 2100 3100 3000 C-8 1.69” -
107003 3 JCD100 Clear 10/500 130 1400 3050 2000 CC-2V 1.69” -
G8 107070 3 JCD100/G8 Clear 10/500 130 1400 3050 2000 CC-2V 1.69” -
JC/
JCD
G6.35
JC
G4
G8
JC
G9
JC
GY6.35
T3
JD
R7s
Bulb Base Product
Number Footnotes Product
Code ANSI Description Pkg.
Qty. Volts Lumens Color
Temp
Avg.
Life
Design
Filament MOL Beam
Spread
J Type Double Ended
75 WATT
T3 R7s 107210 3,8,9 Q75T3C/S - Clear 78mm 10/500 130 1250 2850 2000 C-8 3.07” -
100 WATT
T3 R7s 107182 3,8,9 Q100T3C -Clear 118mm 10/500 130 1400 2950 2000 C-8 4.68” -
107184 3,8,9 Q100T3C/S -Clear 78mm 10/500 130 1400 2950 2000 C-8 3.11” -
150 WATT
T3 R7s 107186 3,8,9 Q150T3C -Clear 118mm 10/500 130 2250 2950 2000 C-8 4.68” -
107188 3,8,9 Q150T3C/S -Clear 78mm 10/500 130 2400 2950 2000 C-8 3.07” -
107214 3,8,9 Q150T3C/12V -Clear 83mm Pool 10/500 12 2500 2950 2000 C-8 3.27” -
200 WATT
T3 R7s 107190 3,8,9 Q200T3C -Clear 118mm 10/500 130 3200 2950 2000 C-8 4.68” -
107192 3,8,9 Q200T3C/S -Clear 78mm 10/500 130 3200 2950 2000 C-8 3.11” -
250 WATT
T3 R7s 107208 3,8,9 Q250T3C/S -Clear 78mm 10/500 130 4000 2950 2000 C-8 3.11” -
107216 3,8,9 Q250T3C/83MM -Clear 83mm Pool 10/500 130 4000 2950 2000 C-8 3.27” -
300 WATT
T3 R7s 107194 3,8,9 Q300T3C -Clear 118mm 10/500 130 5000 2950 2000 C-8 4.68” -
127194 3,8,9 Q300T3C/120 EHM Clear 118mm 10/500 120 5000 2950 2000 C-8 4.68” -
TOC
128
HALOGEN LAMPS
Bulb Base Product
Number Footnotes Product
Code ANSI Description Pkg.
Qty. Volts Lumens Color
Temp
Avg.
Life
Design
Filament MOL Beam
Spread
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T3
R7s
T4
JD
E11
T4
JD
BA15d
J Type Double Ended continued
500 WATT
T3 R7s 107196 3,8,9 Q500T3C DVS Clear 118mm 10/500 130 9500 3000 2000 C-8 4.65” -
127196 3,8,9 Q500T3C/120 FCL Clear 118mm 10/500 120 9500 3000 2000 C-8 4.65” -
1000 WATT
T3 R7s 107198 3,8,9 Q1000T3C -Clear 254mm 10/500 240 22000 3050 2000 C-8 10.00” -
1500 WATT
T3 R7s 107200 3,8,9 Q1500T3C -Clear 254mm 10/500 240 33000 3050 2000 C-8 10.00” -
107202 3,8,9 Q1500T3C/277 -Clear 254mm 10/500 277 33000 3050 2000 C-8 10.00” -
JD Type Single Ended
35 WATT
T4 BA15d 107035 3 Q35CL/DC -Clear 10/400 130 380 2700 2000 CC-2V 1.97” -
E11 107034 3 Q35CL/MC -Clear 10/400 130 380 2700 2000 CC-2V 1.97” -
50 WATT
T4 BA15d 107018 3 Q50CL/DC -Clear 10/400 130 750 2800 2000 CC-2V 1.97” -
E11 107019 3 Q50CL/MC -Clear 10/400 130 750 2800 2000 CC-2V 1.97” -
75 WATT
T4 BA15d 107021 3 Q75CL/DC -Clear 10/400 130 1250 2850 2000 CC-8 2.40” -
E11 107020 3 Q75CL/MC -Clear 10/400 130 1250 2850 2000 CC-8 2.68” -
127020 3 Q75CL/MC/120 -Clear 10/400 120 1250 2850 2000 CC-8 2.68” -
100 WATT
T4 BA15d 107025 3 Q100CL/DC -Clear 10/400 130 1700 2950 2000 CC-8 2.40” -
127025 3 Q100CL/DC/120 ESR Clear 10/400 120 1700 2950 2000 CC-8 2.40” -
E11 107024 3 Q100CL/MC -Clear 10/400 130 1700 2950 2000 CC-8 2.68” -
127024 3 Q100CL/MC/120 ESN Clear 10/400 120 1700 2950 2000 CC-8 2.68” -
150 WATT
T4 BA15d 107029 3 Q150CL/DC -Clear 10/400 130 2400 2950 2000 CC-8 2.40” -
71102 3 Q150CL/DC/120 ETC Clear 10/200 120 2400 2950 2000 CC-8 2.40” -
107027 X 3 Q150DC -Frost 10/400 130 2280 2950 2000 CC-8 2.40” -
E11 107028 3 Q150CL/MC -Clear 10/400 130 2400 2950 2000 CC-8 2.72” -
127028 X Q150CL/MC/120 -Clear 10/400 120 2400 2950 2000 CC-8 2.72” -
107026 3 Q150MC -Frost 10/400 130 2280 2950 2000 CC-8 2.72” -
71100 3 Q150MC/120 ETH Frost 10/200 120 2280 2950 2000 CC-8 2.72” -
Means this lamp meets Federal Minimum Efciency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.
E
TOC
129
HALOGEN LAMPS
Bulb Base Product
Number Footnotes Product
Code ANSI Description Pkg.
Qty. Volts Lumens Color
Temp
Avg.
Life
Design
Filament MOL Beam
Spread
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T4
JD
E11
T4
JD
BA15d
JD Type Single Ended continued
250 WATT
T4 BA15d 107033 3 Q250CL/DC -Clear 10/400 130 4500 2950 2000 CC-8 3.12” -
127033 3 Q250CL/DC/120 ESS Clear 10/400 120 4500 2950 2000 CC-8 3.12” -
71103 X 3 Q250DC/120 ETB Frost 10/200 120 4200 2950 2000 CC-8 2.76” -
107032 3 Q250CL/MC -Clear 10/400 130 4500 2950 2000 CC-8 3.15” -
127032 3 Q250CL/MC/120 EHT Clear 10/400 120 4500 2950 2000 CC-8 3.15” -
107030 3 Q250MC -Frost 10/400 130 4200 2950 2000 CC-8 3.15” -
400 WATT
T4 E11 107037 3 Q400CL/MC -Clear 10/400 130 7400 2950 2000 CC-8 3.27” -
500 WATT
T4 BA15d 107041 X 3 Q500CL/DC -Clear 10/400 130 8500 3000 2000 CC-8 3.98” -
E11 107040 3 Q500CL/MC EYW Clear 10/400 130 8500 3000 2000 CC-8 3.75” -
127040 3 Q500CL/MC/120 EVR Clear 10/400 120 8500 3000 2000 CC-8 3.75” -
107038 3 Q500MC EYV Frost 10/400 130 8075 3000 2000 CC-8 3.75” -
Means this lamp meets Federal Minimum Efciency standards.
Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133.
E
TOC
130
HALOGEN LAMPS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Filament Types
CC-2 CC-6 CC-8
CC indicates coiled-coil lament.
AR111A19 BR BT15 J Type
Tubular
JC JD T10
JDR
Int.
JDR
Med.
MR MR-DC MR-GU10
PAR16 PAR20 PAR30
PAR30L
PAR36 PAR38 PAR46/56/64
Screw
Terminals
Up-term
DC
Bayonet
BA15d
G53 G6.35 or
GY6.35
G8 G9 G4
GU4.
GU5.3
GU10 Intermediate
E17
Medium
E26/27
Mini-Can
E-11
Mogul
End Prong
GX16d
Recessed
Single Contact
R7S
SC
Bayonet
BA15s
Bulb Shapes
Base Types
Bulb, Base and Filament Identication Guide
TOC
131
HALOGEN LAMPS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Symbols, Footnotes and Abbreviations
SYMBOLS
New product introduced within the past year.
NNickel-plated brass base.
$Energy saving product.
This lamp meets Federal Minimum Efciency standards.
XProduct will be discontinued when inventory is depleted.
FOOTNOTES
1
Halogen PAR Caution: Before using bulb, see operating instructions on package. Adhering to these operating
instructions will greatly reduce the risk of personal injury or re. The halogen capsule contained inside this glass
bulb operates under pressure, at high temperatures and could unexpectedly shatter. Should the outer bulb break,
particles of extremely hot glass could be discharged into the xture and/or surrounding area, creating a risk of
personal injury or re. Operating Instructions: Turn power off and let lamp cool before replacing or inspecting
to avoid electrical shock or burn. For indoor and outdoor use. A weather-protected xture is recommended for
wet locations. Suitable for use in open xtures. Do not exceed the xture maximum wattage rating. Do not use
if outer glass is scratched or broken. Lamp may continue to operate if outer glass breaks, however immediately
discontinue use. Do not use in close proximity to combustible materials.
2
HaloXen® lamps operate under high temperatures. To avoid personal injury, turn power off and allow bulb to
cool before attempting to handle. Do not use if the glass is scratched or broken. Do not use near ammable or
combustible materials.
3
Do not touch capsule with bare hands. Oil from the skin may reduce performance unless wiped clean with alcohol
and a soft cloth. CAUTION: THIS LAMP OPERATES UNDER PRESSURE AND COULD SHATTER. To avoid injury
and to avoid exposure to ultraviolet radiation, this lamp should be used in a xture with a protective shield or
tempered glass. Provide adequate ventilation to avoid overheating and use in only xtures rated for wattage stated
on the package. To avoid risks of burns or other injury, turn power off and allow lamp to cool before replacing.
Socket condition may affect lamp life. Inspect and replace socket if deterioration occurs.
4Socket condition may affect lamp life. Inspect and replace socket if deterioration occurs.
5This lamp should be shielded from moisture to prevent breakage.
6Use only with heat-resistant connector and with lamp supported by bulb rim.
7Use only in heat-resistant lamp holders and xtures rated for reector or PAR lamps.
8Use outdoors only in enclosed xtures or where lamp is protected from exposure to water.
Use only in xtures rated for this product.
9Operate in a horizontal position only.
E
TOC
132
HALOGEN LAMPS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
/12V Sufx used to indicate 12 Volt lamps.
/24V Sufx used to indicate 24 Volt lamps.
/83mm Sufx used to indicate lamps with MOL of 83mm.
/120 Sufx used to indicate 120 Volt lamps.
/130 Sufx used to indicate 130 Volt lamps.
/277V Sufx used to indicate 277 Volt lamps.
/AL Sufx used to indicate lamps with an Aluminum Back reector.
/BA9s Sufx used to indicate lamps with a BA9s base.
/BA15d Sufx used to indicate lamps with a BA15d base.
/BA15s Sufx used to indicate lamps with a BA15s base.
/BLK Sufx used to indicate lamps with a Black Back, coated reector.
/BLU Sufx used to indicate lamps with a Blue lens.
CL Code abbreviation for lamps with a Clear nish.
/CS Sufx used to indicate CoverShield® Safety Coated lamps.
/DC Sufx used to indicate lamps with a DC (BA15d) base.
FL Code abbreviation for Flood lamps.
/FR Sufx used to indicate lamps with a Frost Finish.
/G4 Sufx used to indicate lamps with a G4 base.
/G8 Sufx used to indicate lamps with a G8 base.
/G9 Sufx used to indicate lamps with a G9 base.
/GU10 Sufx used to indicate lamps with a GU10 base.
/GRN Sufx used to indicate lamps with a Green lens.
/H Sufx used to indicate Halogen lamps.
HP Code abbreviation for Halogen PAR lamps.
/HX Sufx used to indicate HaloXen® lamps.
TOC
133
HALOGEN LAMPS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
INT Code abbreviation for Intermediate (E17) base.
LCode abbreviation for PAR30 lamps with a long neck.
/L Sufx used to indicate lamps with a lens.
LM Code abbreviation for lumens.
/MC Sufx used to indicate lamps Mini-Candelabra (E11) base.
NFL Code abbreviation for Narrow Flood lamps.
/M Sufx used to indicate Major brand lamps (GE, Philips, Osram/Sylvania).
MED Code abbreviation for lamps with a Medium (E26/27) base.
NSP Code abbreviation for Narrow Spot lamps.
QCode abbreviation to indicate Quartz Halogen.
/RED Sufx used to indicate lamps with a Red lens.
/S Sufx used to indicate Silver PAR HaloXen® lamps.
/SC Sufx used to indicate Prism® SureColor® lamps.
/SIL Sufx used to indicate lamps with a Silver Back, coated reector.
SP Code abbreviation for Spot lamps.
/SW Sufx used to indicate lamps with a Soft White nish.
/TL Sufx used to indicate lamps with a Twist Lock base (BA15d).
/U Sufx used to indicate Prism® Ultra Life® 12,000 hour lamps.
VNSP Code abbreviation fro Very Narrow Spot lamps.
WCode abbreviation for Wide Flood lamps.
WFL Code abbreviation for Wide Flood lamps.
/X Sufx used to indicate Xenon lamps.
/YEL Sufx used to indicate lamps with a Yellow nish.
/XIR Sufx used to indicate Halogen Infrared lamps.
TOC
How to Read a Table
General Service Lamps
Decorative Lamps
Bulb, Base and Filament Identication
Symbols, Footnotes and Abbreviations
136
137
147
150
151
CONTENTS
INCANDESCENT LAMPS
®
main
TOC
7.5 WATT
S11 Med. 7017 S11CL7.5 Clear 25/500 130 45 1500 C-7A 2.25” -
7024 S11GRN7.5C Ceramic Green 25/500 130 - 1500 C-7A 2.25” -
7026 S11ORG7.5C Ceramic Orange 25/500 130 - 1500 C-7A 2.25” -
7019 S11RED7.5C Ceramic Red 25/500 130 - 1500 C-7A 2.25” -
7020 S11WH7.5C Ceramic White 25/500 130 - 1500 C-7A 2.25” -
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
HOW TO READ AN INCANDESCENT LAMP TABLE
BULB
Designations indicate shape and
size. Illustrations can be found on
page 150 and at the top of each
page.
BASE
Indicates base type.
Full base descriptions
and illustrations can be
found on page 150.
PACKAGE QUANTITY
Indicates minimum sell quantity
and smallest shipping carton.
VOLTS
Indicate the
product’s
design voltage
of operation.
DESIGN
FILAMENT
Filament types are
illustrated on page
150.
PRODUCT CODE
Abbreviated product description
can also be used for ordering.
A key to abbreviations can be
found on page 152.
WATTS
Indicates the
power consumed
by the lamp during
operation.
PRODUCT
NUMBER
Use this number
when placing an
order.
AVERAGE
LIFE
Average rated life
expressed in hours.
BEAM
SPREAD
Indicates the
beam angle or
beam spread
of a bulb,
measured in
degrees.
FOOTNOTES &
SYMBOLS
Related footnotes can
be found on page 151.
LUMENS
Represents average
light output.
DESCRIPTION
Bulb nish and other
important information.
MOL
Indicates
maximum
overall length
in inches.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
4 WATT
C7 Cand. 7014 C7CL4 Clear 25/1000 130 16 1000 C-3A 2.12” -
5 WATT
C7 Cand. 7102 C7AMB5T Transparent Amber 25/1000 130 - 1000 C-3A 2.12” -
7104 C7BLU5C Ceramic Blue 25/1000 130 - 1000 C-3A 2.12” -
7106 C7BLU5T Transparent Blue 25/1000 130 - 1000 C-3A 2.12” -
7108 C7GRN5C Ceramic Green 25/1000 130 - 1000 C-3A 2.12” -
7110 C7GRN5T Transparent Green 25/1000 130 - 1000 C-3A 2.12” -
7112 C7ORG5C Ceramic Orange 25/1000 130 - 1000 C-3A 2.12” -
7114 C7RED5C Ceramic Red 25/1000 130 - 1000 C-3A 2.12” -
7116 C7RED5T Transparent Red 25/1000 130 - 1000 C-3A 2.12” -
7118 C7WH5C Ceramic White 25/1000 130 - 1000 C-3A 2.12” -
6 WATT
S6 Cand. 9042 S6CL6 Clear 25/2000 130 30 1500 C-7A 1.87” -
9043 S6CL6/145V Clear 25/2000 145 30 1500 C-7A 1.87” -
7 WATT
C7 Cand. 7016 C7CL7 Clear 25/1000 130 40 1000 C-3A 2.12” -
105204 C7WH7/NL White Night Light 25/2000 130 - 1000 C-3A 2.12” -
C9 Int. 7050 C9CL7 Clear 25/1000 130 40 3000 C-3A 3.00” -
7120 C9AMB7T Transparent Amber 25/1000 130 - 3000 C-3A 3.00” -
7122 C9BLU7C Ceramic Blue 25/1000 130 - 3000 C-3A 3.00” -
7124 C9BLU7T Transparent Blue 25/1000 130 - 3000 C-3A 3.00” -
7126 C9GRN7C Ceramic Green 25/1000 130 - 3000 C-3A 3.00” -
7128 C9GRN7T Transparent Green 25/1000 130 - 3000 C-3A 3.00” -
7130 C9ORG7C Ceramic Orange 25/1000 130 - 3000 C-3A 3.00” -
7132 C9RED7C Ceramic Red 25/1000 130 - 3000 C-3A 3.00” -
7134 C9RED7T Transparent Red 25/1000 130 - 3000 C-3A 3.00” -
7.5 WATT
S11 Med. 7017 S11CL7.5 Clear 25/500 130 45 1500 C-7A 2.25” -
7024 S11GRN7.5C Ceramic Green 25/500 130 - 1500 C-7A 2.25” -
7026 S11ORG7.5C Ceramic Orange 25/500 130 - 1500 C-7A 2.25” -
7019 S11RED7.5C Ceramic Red 25/500 130 - 1500 C-7A 2.25” -
7020 S11WH7.5C Ceramic White 25/500 130 - 1500 C-7A 2.25” -
7028 S11YEL7.5C Ceramic Yellow 25/500 130 - 1500 C-7A 2.25” -
10 WATT
S11 Int. 9045 S11CL10 Clear 25/500 130 80 1500 C-7A 2.48” -
S6
S11
Cand.
C7/C9
Cand.
137
General Service
INCANDESCENT LAMPS
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
E Means this lamp meets Federal Minimum Efciency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
11 WATT
S14 Med. 9051 S14CL11 Clear 25/250 130 80 5000 C-9 3.50” -
9057 S14FR11 Frost 25/250 130 75 3000 C-9 3.50” -
9056 S14AMB11T Transparent Amber 25/250 130 - 3000 C-9 3.50” -
9076 S14BLU11C Ceramic Blue 25/250 130 - 3000 C-9 3.50” -
9055 S14BLU11T Transparent Blue 25/250 130 - 3000 C-9 3.50” -
9070 S14GRN11C Ceramic Green 25/250 130 - 3000 C-9 3.50” -
9054 S14GRN11T Transparent Green 25/250 130 - 3000 C-9 3.50” -
105334 S14RED11C Ceramic Red 25/250 130 - 3000 C-9 3.50” -
9052 S14RED11T Transparent Red 25/250 130 - 3000 C-9 3.50” -
9058 S14WH11C Ceramic White 25/250 130 - 3000 C-9 3.50” -
105336 S14YEL11C Ceramic Yellow 25/250 130 - 3000 C-9 3.50” -
9053 S14YEL11T Transparent Yellow 25/250 130 - 3000 C-9 3.50” -
15 WATT
A15 Med. 6013 A15CL15 Clear 20/120 130 95 3000 C-9 3.50” -
6014 A15FR15 Frost 20/120 130 90 3000 C-9 3.50” -
T6 Cand. 9030 T6CL15/CAN Clear 25/500 130 90 2000 C-5A 3.06” -
9021 T6CL15/145V Clear 25/500 145 80 2000 C-5A 3.06” -
T7 Cand. 9039 T7CL15CAN Clear 25/1000 120 100 2000 C-5A 2.25” -
BA15d 9038 T7CL15DC Clear 25/1000 120 100 2000 C-5A 2.35” -
Int. 9037 T7CL15INT Clear 25/1000 120 100 2000 C-5A 2.35” -
20 WATT
PAR36 Screw
Term.
107788 $,17 HP36NSP20/HX Narrow Spot HaloXen® 12 12 260 5000 C-6 2.75” 12°
107790 $,17 HP36VNSP20/HX Very Narrow Spot HaloXen®12 12 260 5000 C-6 2.75” 5°
107792 $,17 HP36WFL20/HX Wide Flood HaloXen® 12 12 260 5000 C-6 2.75” 32°
T6.5 BA15d 9022 T6.5CL20DC Clear 25/500 130 150 2500 C-8 5.56” -
9023 T6.5FR20DC Frost 25/500 130 150 2500 C-8 5.56” -
Int. 9019 T6.5CL20INT Clear 25/500 130 150 2500 C-8 5.50” -
9028 T6.5FR20INT Frost 25/500 130 150 2500 C-8 5.50” -
25 WATT
A15 Med. 6016 A15CL25 Clear 20/120 130 130 3000 C-9 3.50” -
6015 A15FR25 Frost 20/120 130 120 3000 C-9 3.50” -
A19 Med. 6318 A19CL25/5 Clear 120 130 175 5000 C-9 4.25” -
103700 Al A19FR25 Frost 120 130 160 1500 C-9 4.25” -
6319 A19FR25/5 Frost 120 130 150 5000 C-9 4.25” -
101159 10 A19FR25/12V Frost 12/240 12 240 2000 C-6 4.25” -
101150 A19BLU25T Transparent Blue 12/120 130 - 2000 C-9 4.25” -
T6.5
A15
A19 S14
T6PAR36T7
General Service
138
INCANDESCENT LAMPS
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
E Means this lamp meets Federal Minimum Efciency standards.
Incandescent lamp symbols, footnotes and abbreviations are located on pages 151-153.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
25 WATT continued
A19 Med. 101152 A19GRN25T Transparent Green 12/120 130 - 2000 C-9 4.25” -
6335 A19RED25C Ceramic Red 12/120 130 - 2000 C-9 4.25” -
101154 A19RED25T Transparent Red 12/120 130 - 2000 C-9 4.25” -
101124 A19RS25/CS CoverShield®20/120 130 - 2000 C-9 4.25” -
6338 A19YEL25C Ceramic Yellow 12/120 130 - 2000 C-9 4.25” -
101156 A19YEL25T Transparent Yellow 12/120 130 - 2000 C-9 4.25” -
C11 Cad. 20003 C11ANT25 Antique Oil-Rubbed nish 10/100 120 120 3000 Z-Shape 4.00” -
PAR36 Screw
Term.
14554 10 PAR36NSP25/M Narrow Spot Major 1/12 12 150 2000 C-6 2.75”
14556 10 PAR36VWFL25/M Very Wide Flood Major 1/12 12 150 2000 C-6 2.75” 55°
65205 10 PAR36WFL25 Wide Flood 1/12 12 150 2000 C-6 2.75” 25x37
R14 Int. 9104 R14INT25 Flood 25/250 130 150 1500 CC-2V 2.64” -
Med. 9103 R14MED25 Flood 25/250 130 150 1500 CC-2V 2.64” -
S11 Int. 9048 S11N25 Clear High-Intensity 25/500 130 200 1500 CC-2V 2.48” -
T6.5 BA15d 9025 T6.5CL25DC Clear 25/500 130 180 2500 C-8 5.56” -
Int. 9018 T6.5CL25INT Clear 25/500 130 180 2500 C-8 5.50” -
T8 BA15d 9034 T8CL25DC Clear 25/500 130 180 2500 C-8 2.63” -
Int. 9032 T8CL25INT Clear 25/500 130 180 2500 C-8 2.63” -
T10 Med. 9012 T10CL25 Clear 25/200 130 180 2500 C-5V 5.00” -
9013 T10FR25 Frost 25/200 130 180 2500 C-5V 5.00” -
29 WATT
A19 Med. 76005 $ A19CL29/H Clear 12/120 120 430 1000 CC-8 4.25” -
76001 $ A19SW29/H Soft White 12/120 120 430 1000 CC-8 4.25” -
30 WATT
R20 Med. 9110 6 R20FL30 Flood 10/100 130 140 3000 C-9 3.93” -
10102 R20FL30/CS Flood CoverShield®10/100 130 140 3000 C-9 3.93” -
30/70/100 WATT
A21 Med. 8009 1 A21SW3W100 Soft White 3-Way 30/70/100 12/60 130 260/
650/940 2500 CC-8 5.25” -
35 WATT
PAR20 Med. 107610 N,$,18 HP20NFL35 Narrow Flood Prism®15 130 450 3000 CC-8 3.07” 30°
PAR36 Screw
Term.
107794 $,17 HP36NSP35/HX Narrow Spot HaloXen®1/12 12 540 5000 C-6 2.75” 12°
107796 $,17 HP36VNSP35/HX Very Narrow Spot HaloXen®1/12 12 540 5000 C-6 2.75” 5°
107798 $,17 HP36WFL35/HX Wide Flood HaloXen®1/12 12 540 5000 C-6 2.75” 32°
70306 $,17 HP36WFL35/24V Wide Flood 1/12 24 500 5000 CC-6 2.75” 32°
E
E
PAR20 PAR36 R14 S11T6.5
T8
T10 R20
A19
A21
PAR30
PAR30L C11
139
General Service
INCANDESCENT LAMPS
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
E Means this lamp meets Federal Minimum Efciency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
General Service
140
INCANDESCENT LAMPS
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
39 WATT
PAR20 Med. 70343 $,,17 HP20NFL39/HX Narrow Flood HaloXen®1/15 120 530 2000 CC-8 3.23” 30°
70354 $,,17 HP20NFL39/HX/130 Narrow Flood HaloXen®1/15 130 530 2000 CC-8 3.23” 30°
PAR30 Med. 70347 $,,17 HP30FL39/HX Flood HaloXen®1/15 120 530 2000 CC-8 3.62” 30°
70353 $,,17 HP30FL39/HX/130 Flood HaloXen®1/15 130 530 2000 CC-8 3.62” 30°
PAR30L Med. 70344 $,,17 HP30FL39L/HX Flood HaloXen®1/15 120 530 2000 CC-8 4.75” 36°
70204 $,,17 HP30WFL39L/HX Wide Flood HaloXen®1/15 120 530 2000 CC-8 4.75” 50°
70203 $,,17 HP30SP39L/HX Spot HaloXen®1/15 120 530 2000 CC-8 4.75” 15°
70356 $,,17 HP30FL39L/HX/130 Flood HaloXen®1/15 130 530 2000 CC-8 4.75” 36°
PAR38 Med. 70340 $,,17 HP38FL39/HX Flood HaloXen®1/15 120 530 2000 CC-8 5.31” 30°
70404 $,,17 HP38SP39/HX Spot HaloXen®1/15 120 530 2000 CC-8 5.31” 10°
70355 $,,17 HP38FL39/HX/130 Flood HaloXen®1/15 130 530 2000 CC-8 5.31” 30°
40 WATT
A15 Cand. 10005 A15CL40/E12 Clear 20/120 120 350 2000 C-9 3.50” -
10006 X A15WH40/E12 White 20/120 120 310 2000 C-9 3.50” -
Int. 10009 X A15CL40/E17 Clear 20/120 120 350 2000 C-9 3.50” -
Med. 6017 A15CL40 Clear 20/120 130 300 3000 C-9 3.50” -
90300 A15CL40/CSTF Clear CoverShield® PFA 20/120 130 300 3000 C-9 3.50” -
6018 A15FR40 Frost 20/120 130 290 3000 C-9 3.50” -
6146 A15RS40/CS CoverShield®20/120 130 - 1500 C-9 3.50” -
A19 Med. 103710 L, Al A19CL40 Clear 120 130 340 1500 C-9 4.25” -
6324 A19CL40/5 Clear 120 130 320 5000 C-9 4.25” -
103702 L, Al A19FR40 Frost 120 130 325 1500 C-9 4.25” -
6320 A19FR40/5 Frost 120 130 275 5000 C-9 4.25” -
6220 A19SW40/120 Soft White 120 120 300 1500 CC-6 4.25” -
8013 A19BG40 Yellow Bug 20/120 130 - 2000 C-9 4.25” -
101151 X A19BLU40T Transparent Blue 12/120 130 - 2000 C-9 4.25” -
101153 X A19GRN40T Transparent Green 12/120 130 - 2000 C-9 4.25” -
101155 A19RED40T Transparent Red 12/120 130 - 2000 C-9 4.25” -
101125 A19RS40/CS CoverShield®20/120 130 - 2000 C-9 4.25” -
6354 X A19YEL40C Ceramic Yellow 12/120 130 - 2000 C-9 4.25” -
A21 Med. 20002 A21ANT40 Antique Oil-Rubbed nish 6/48 120 130 3000 Quad
Loop 5.00” -
R14 Int. 9101 R14INT40 Flood 25/250 130 260 1500 CC-2V 2.64” -
Med. 9100 R14MED40 Flood 25/250 130 260 1500 CC-2V 2.64” -
R16 Med. 9127 R16MED40 Flood 25/500 130 235 3000 C-9 3.66” -
129127 R16MED40/120 Flood 25/500 120 235 3000 C-9 3.66” -
104106 R16SP40 Spot 25/500 130 235 3000 CC-2V 3.66” -
R14
R16
A15
A19
A21
PAR20
PAR30
PAR30L PAR38
E Means this lamp meets Federal Minimum Efciency standards.
Incandescent lamp symbols, footnotes and abbreviations are located on pages 151-153.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 141
General Service
INCANDESCENT LAMPS
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
40 WATT continued
T6.5 Int. 106111 T6.5CL40INT Clear 25/500 130 350 2500 C-8 5.50” -
T10 Med. 9014 T10CL40 Clear 25/200 130 280 2500 C-5V 5.00” -
9015 T10FR40 Frost 25/200 130 280 2500 C-5V 5.00” -
106228 T10CL40/CS CoverShield®25/200 130 - - C-5V 5.00” -
G30 Med. 20004 G30ANT40 Antique Oil-Rubbed nish 50 120 140 3000 Squirrel
Cage 5.13” -
G40 Med. 20005 G40ANT40 Antique Oil-Rubbed nish 12 120 140 3000 Squirrel
Cage 6.75” -
S11 Int. 9050 S11N40 Clear High-Intensity 25/500 130 370 1500 CC-2V 2.48” -
ST18 Med. 20006 ST18ANT40 Antique Oil-Rubbed nish 10/100 120 135 3000 Squirrel
Cage 5.16” -
T14 Med. 20007 T14ANT40 Antique Oil-Rubbed nish 10/100 120 135 3000 Squirrel
Cage 4.25” -
43 WATT
A19 Med. 76006 $ A19CL43/H Clear 12/120 120 750 1000 CC-8 4.25” -
76004 $ A19SW43/H Soft White 12/120 120 750 1000 CC-8 4.25” -
45 WATT
PAR16 Med. 107502 N, $,18 HP16NFL45 Narrow Flood Prism®15 130 500 3000 CC-2V 3.07” 30°
R20 Med. 10100 6 R20FL45 Flood 10/100 130 450 3000 C-9 3.93” -
50 WATT
A19 Med. 101160 10 A19FR50/12V Frost 12/240 12 580 1500 C-6 4.25” -
101123 A19RS50 Rough Service 20/120 130 580 2500 C-9 4.25” -
BR30 Med. 104058 6 BR30FL50 Flood 24 130 300 5000 C-9 5.37” -
ER30 Med. 9113 5,7 ER30FL50/P5 Flood Prism® Long Life Plus12/60 130 360 5000 C-9M 6.25” -
PAR36 Screw
Term.
107782 17 HP36NSP50/HX Narrow Spot HaloXen® 1/12 12 910 5000 C-6 2.75” 12°
107784 17 HP36VNSP50/HX Very Narrow Spot HaloXen®1/12 12 910 5000 C-6 2.75” 5°
107786 17 HP36WFL50/HX Wide Flood HaloXen® 1/12 12 910 5000 C-6 2.75” 32°
65210 10 PAR36WFL50 Wide Flood 1/12 12 330 2000 C-6 2.75” 39x27
PAR38 Med. 70350 ,17 HP38FL50/S/HX Silver PAR Flood HaloXen®1/15 120 920 1500 CC-8 5.31” 30°
R20 Med. 104200 6 R20AMB50 Amber 10/100 130 - 2500 C-9 3.93” -
9146 6 R20BLU50 Blue 10/100 130 - 2500 C-9 3.93” -
9150 6 R20DPNK50 Dawn Pink 10/100 130 - 2500 C-9 3.93” -
9141 6 R20GRN50 Green 10/100 130 - 2500 C-9 3.93” -
9108 6 R20PNK50 Pink 10/100 130 - 2500 C-9 3.93” -
9142 6 R20RED50 Red 10/100 130 - 2500 C-9 3.93” -
104016 6 R20FL50/CS CoverShield®10/100 130 - 2000 C-9 3.93” -
E
E
E
T10
T14 S11
T6.5 R20
PAR30
PAR30L BR30
A19
A21 PAR16
ER30 PAR38 PAR36
ST18 G30
E Means this lamp meets Federal Minimum Efciency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
General Service
142
INCANDESCENT LAMPS
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
50/100/150 WATT
A21 Med. 8010 1 A21SW3W150 Soft White 3-Way
50/100/150 12/60 130
560/
1200/
1760
2500 CC-8 5.25” -
101240 X,N,1 A21FR50/150/ND Frost 3-Way 50/100/150
Neodymium PureLite®12/60 120
380/
1000/
1380
5000 CC-8 5.25” -
53 WATT
A19 Med. 76007 $ A19CL53/H Clear 12/120 120 1050 1000 CC-8 4.25” -
76002 $ A19SW53/H Soft White 12/120 120 1050 1000 CC-8 4.25” -
PAR30 Med. 70310 ,17 HP30FL53/XIR Flood XIR® 1/15 120 1050 3500 CC-8 3.62” 30°
PAR30L Med. 70311 ,17 HP30FL53L/XIR Flood XIR®1/15 120 930 3500 CC-8 4.75” 30°
PAR38 Med. 70312 ,17 HP38FL53/XIR Flood XIR®1/15 120 960 3500 CC-8 5.31” 25°
54 WATT
A19 Med. 288584 $ A19FR54/10 Frost Prism® Ultra Life®20/120 130 450 10000 C-9M 4.25” -
60 WATT
A15 Cand. 10007 A15CL60/E12 Clear 20/120 120 530 2000 C-9 3.50” -
10008 A15WH60/E12 White 20/120 120 520 2000 C-9 3.50” -
Med. 6117 A15CL60 Clear 20/120 130 530 3000 C-9 3.50” -
126117 A15CL60/120 Clear 20/120 120 620 3000 C-9 3.50” -
101234 X, N A15CL60/ND Clear Neodymium PureLite®10/50 120 530 5000 CC-9 3.50” -
6118 A15FR60 Frost 20/120 130 520 3000 C-9 3.50” -
6147 A15RS60/CS CoverShield®20/120 130 - 1500 C-9 3.50” -
A19 Med. 103712 L, Al A19CL60 Clear 120 130 620 1500 C-9 4.25” -
6225 L A19CL60/120 Clear 120 120 590 1500 CC-6 4.25” -
6325 L A19CL60/5 Clear 120 130 545 5000 C-9 4.25” -
103010 L A19CL60/P10 Clear Prism® Ultra Life®20/120 120 480 10000 C-9M 4.25” -
101242 N A19CL60/ND Clear Neodymium PureLite®20/120 120 600 5000 CC-6 4.25” -
101180 3 A19CL60/SB Clear Silver Bowl Prism®12/120 130 - 2500 C-9 4.25” -
103704 L, Al A19FR60 Frost 120 130 590 1500 C-9 4.25” -
6321 L A19FR60/5 Frost 120 130 510 5000 C-9 4.25” -
103024 L A19FR60/P10 Frost Prism® Ultra Life®20/120 120 480 10000 C-9M 4.25” -
101194 N A19FR60/ND Frost Neodymium PureLite®20/120 120 600 5000 CC-6 4.25” -
101184 3 A19FR60/SB Inside Frost Silver Bowl Prism®12/120 130 - 5000 C-9 4.25” -
6221 L A19SW60/120 Soft White 120 120 530 1500 C-9 4.25” -
8011 A19BG60 Yellow Bug 20/120 130 - 2000 C-9 4.25” -
101196 X A19GRO60 Plant Grow 12/120 120 480 2000 C-9 4.25” -
6352 A19RED60C Ceramic Red 12/120 130 - 2000 C-9 4.25” -
E
E
E
E
E
PAR30
PAR30L
A15
A19
A21 PAR38
E Means this lamp meets Federal Minimum Efciency standards.
Incandescent lamp symbols, footnotes and abbreviations are located on pages 151-153.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 143
General Service
INCANDESCENT LAMPS
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
60 WATT continued
A19 Med. 6151 A19RS60 Rough Service 20/120 130 780 2500 C-9 4.25” -
6141 A19RS60/CS CoverShield®20/120 130 - 2000 C-9 4.25” -
6356 A19YEL60C Ceramic Yellow 12/120 130 - 2000 C-9 4.25” -
PAR16 Med. 107616 N,$,18 HP16NFL60 Narrow Flood Prism®15 130 550 3000 CC-8 3.07” 30°
107850 N,$,18 HP16NFL60/120 Narrow Flood Prism®15 120 550 3000 CC-8 3.07” 30°
107504 N,$,18 HP16NSP60 Narrow Spot Prism®15 130 550 3000 CC-8 3.07” 10°
T10 Med. 9016 T10CL60 Clear 25/200 130 420 2500 C-5V 5.00” -
9017 T10FR60 Frost 25/200 130 420 2500 C-5V 5.00” -
PAR30 Med. 70345 $,17 HP30FL60/S/HX Silver PAR Flood HaloXen®1/15 120 1090 1500 CC-8 3.62” 30°
PAR30L Med. 70342 $,17 HP30FL60L/S/HX Silver PAR Flood HaloXen®1/15 120 1090 1500 CC-8 4.75” 36°
70349 $,17 HP30WFL60L/S/HX
Silver PAR Wide Flood HaloXen
®
1/15 120 1090 1500 CC-8 4.75” 50°
70348 $,17 HP30SP60L/S/HX Silver PAR Spot HaloXen®1/15 120 1090 1500 CC-8 4.75” 15°
PAR38 Med. 70341 $,17 HP38FL60/S/HX Siver PAR Flood HaloXen®1/15 120 1090 1500 CC-8 5.31” 30°
65 WATT
BR30 Med. 104070 6 BR30FL65 Flood 24 130 580 5000 C-9 5.37” -
124070 6 BR30FL65/120 Flood 24 120 510 5000 C-9 5.37” -
75009 ,19 BR30FL65/H Flood 24 120 750 2500 CC-8 5.37” -
103620 6 BR30FL65/P5 Flood Prism® Long Life Plus 24 130 480 5000 C-9M 5.37” -
103110 6 BR30FL65/P10 Flood Prism® Ultra Life®24 120 420 10000 C-9M 5.37” -
103528 N, 6 BR30FL65/20 Flood Prism® Ultra Life®24 120 480 20000 C-9M 5.37” -
404014 6 BR30SP65/5 Spot 24 130 - 5000 C-9 5.37” -
404028 6 BR30AMB65/5 Amber Prism®12/24 130 - 5000 C-9 5.37” -
404030 6 BR30BLU65/5 Blue Prism®12/24 130 - 5000 C-9 5.37” -
404031 6 BR30DPNK65/5 Dawn Pink Prism®12/24 130 - 5000 C-9 5.37” -
404039 6 BR30GRN65/5 Green Prism®12/24 130 - 5000 C-9 5.37” -
404046 6 BR30PNK65/5 Pink Prism®12/24 130 - 5000 C-9 5.37” -
404049 6 BR30RED65/5 Red Prism®12/24 130 - 5000 C-9 5.37” -
404051 6 BR30FL65/CS CoverShield® Prism®1/24 130 - 5000 C-9 5.37” -
404053 6 BR30YEL65/5 Yellow Prism®12/24 130 - 5000 C-9 5.37” -
BR40 Med. 404076 6 BR40FL65/P5 Flood Prism® Long Life Plus 24 130 550 5000 C-9M 6.56” -
75010 ,19 BR40FL65/H Flood 24 120 750 2500 CC-8 6.56” -
68 WATT
A19 Med. 288580 11 A19FR68/10 Frost Prism® Ultra Life®20/120 130 630 10000 C-9M 4.25” -
E
E
E
E
E
T10PAR16A19
PAR30
PAR30L PAR38
BR30
BR40
E Means this lamp meets Federal Minimum Efciency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
General Service
144
INCANDESCENT LAMPS
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
70 WATT
PAR38 Med. 70346 $,17 HP38FL70/S/HX Silver PAR Flood HaloXen®1/15 120 1350 1500 CC-8 5.31” 30°
70352 $,17 HP38SP70/S/HX Silver PAR Spot HaloXen®1/15 120 1350 1500 CC-8 5.31” 10°
72 WATT
A19 Med. 76000 $ A19CL72/H Clear 12/120 120 1490 1000 CC-8 4.25” -
76003 $ A19SW72/H Soft White 12/120 120 1490 1000 CC-8 4.25” -
75 WATT
A19 Med. 103714 L, Al A19CL75 Clear 120 130 860 1500 C-9 4.25” -
6326 L A19CL75/5 Clear 120 130 700 5000 C-9 4.25” -
103706 L, Al A19FR75 Frost 120 130 820 1500 C-9 4.25” -
6322 L A19FR75/5 Frost 120 130 680 5000 C-9 4.25” -
6222 L A19SW75/120 Soft White 120 120 780 1500 CC-6 4.25” -
6152 A19RS75 Rough Service 20/120 130 1100 2500 C-9 4.25” -
6142 A19RS75/CS CoverShield®20/120 130 - 2000 C-9 4.25” -
A21 Med. 101248 N A21FR75/ND Frost Neodymium PureLite®12/60 120 710 5000 CC-6 5.00” -
80 WATT
PAR38 Med. 70351 $,17 HP38FL80/S/HX Silver PAR Flood HaloXen®1/15 120 1580 1500 CC-8 5.31” 30°
100 WATT
A19 Med. 6327 L A19CL100/5 Clear 120 130 1000 5000 C-9 4.25” -
101182 3,8 A19CL100/SB Clear Silver Bowl Prism®12/120 130 830 5000 C-9 4.25” -
6323 L A19FR100/5 Frost 120 130 980 5000 C-9 4.25” -
103028 L A19FR100/P10 Frost Prism® Ultra Life®20/120 120 870 10000 C-9M 4.25” -
6223 X A19SW100/120 Soft White 120 120 1050 1500 CC-6 4.25” -
6153 A19RS100 Rough Service 20/120 130 1150 2500 C-9 4.25” -
6143 A19RS100/CS CoverShield®20/120 130 - 2500 C-9 4.25” -
A21 Med. 101246 N A21CL100/ND Clear Neodymium PureLite®12/60 120 1050 5000 CC-6 5.00” -
103576 X A21FR100/P5 Frost Prism® Long Life Plus™ 12/60 130 1050 5000 C-9M 5.00” -
101197 N A21FR100/ND Frost Neodymium PureLite®12/60 120 1050 5000 CC-6 5.00” -
101190 3,8 A21FR100/SB Inside Frost Silver Bowl Prism®12/60 130 800 5000 C-9 5.00” -
6041 A21RS100/P5/CS CoverShield® Prism®12/60 130 - 5000 C-9M 5.00” -
E
E
E
E
E
A19
A21
PAR38
E Means this lamp meets Federal Minimum Efciency standards.
Incandescent lamp symbols, footnotes and abbreviations are located on pages 151-153.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 145
General Service
INCANDESCENT LAMPS
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
100 WATT continued
BR30 Med. 104026 6,10 BR30CL100/12V Clear Pool Lamp 12/24 12 1200 2000 C-6 5.37” -
BR38 Med. 404112 9 BR38AMB100 Amber Flood 12/24 130 - 5000 C-9 5.50” -
404113 9 BR38BLU100 Blue Flood 12/24 130 - 5000 C-9 5.50” -
404114 9 BR38GRN100 Green Flood 12/24 130 - 5000 C-9 5.50” -
404116 9 BR38RED100 Red Flood 12/24 130 - 5000 C-9 5.50” -
404119 9 BR38YEL100 Yellow Flood 12/24 130 - 5000 C-9 5.50” -
R20 Med. 104020 2,6,10 R20CL100/12V Clear Pool Lamp 10/100 12 950 2000 C-6 3.55” -
100/200/300 WATT
PS25 Mog. 8005 1 PS25SW3W300 Soft White 3-Way
100/200/300 Prism®12/60 120
1200/
2600/
3800
1200 CC-6 6.93” -
120 WATT
BR40 Med. 404065 6 BR40FL120/5/CS CoverShield®1/24 120 - 5000 C-9 6.56” -
PAR38 Side
Prong
65058 X,4,13 PAR38/3SP120 Spot 1/12 120 1370 2000 CC-6 4.30” 18°
65059 X,4,13 PAR38/3FL120 Flood 1/12 120 1370 2000 CC-6 4.30” 30°
125 WATT
BR40 Med. 204035 6,11 BR40CL125/1 Clear Infrared Prism®12 120 - 6000 C-9 6.56” -
150 WATT
A21 Med 6043 A21RS150/P5/CS CoverShield®1/60 130 - 5000 C-9M 5.00” -
PS25 Med. 401345 3 PS25CL150/P5/CS CoverShield® Prism®
Long Life Plus™ 1/60 130 - 5000 C-9M 6.93” -
104012 X R40GRO150 Plant Grow 12 120 - 5000 C-9 6.56” -
200 WATT
PAR46 Side
Prong
65064 4,13 PAR46/3MFL200 Medium Flood 1/12 120 2270 2000 CC-13 4.00” 25x15
65065 4,13 PAR46/3NSP200 Narrow Spot 1/12 120 2270 2000 CC-13 4.00” 12x8
PS25 Med. 401347 3 PS25CL200/P5/CS CoverShield® Prism®
Long Life Plus™ 1/60 130 - 5000 C-9M 6.93” -
250 WATT
BR40 Med. 404068 6,11 BR40CL250/1 Clear Heat Prism®12 120 - 5000 C-9 6.56” -
404066 6,11,16 BR40CL250/1/CSTF Clear CoverShield® PFA Prism®1/12 120 - 5000 C-9 6.56” -
PAR38 Med. 15558 Q250PAR/FL Flood Major 1/6 120 3600 4200 CC-8 5.31” 30°
15526 Q250PAR/SP Spot Major 1/6 120 3600 4200 CC-8 5.31” 10°
R40 Med. 104044 6,11 R40RED250/10 Red Heat Prism®12 120 - 5000 C-9 6.56” -
404071 6,11,16 R40RED250/10/CSTF Red CoverShield® PFA Prism®1/12 120 - 5000 C-9 6.56” -
PAR38A21
BR30
BR38
BR40
PAR38
PAR46
Side
Prong PS25 R20
E Means this lamp meets Federal Minimum Efciency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
General Service
146
INCANDESCENT LAMPS
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
300 WATT
PAR56 Mog.
End
Prong
65220 4,13 PAR56MFL300 Medium Flood 1/12 120 3840 2000 CC-13 5.00” 25x11
65042 4,13 PAR56NSP300 Narrow Spot 1/12 120 3840 2000 CC-13 5.00” 10x8
65230 4,13 PAR56WFL300 Wide Flood 1/12 120 3840 2000 CC-13 5.00” 35x20
Screw
Term. 65225 4,10,13 PAR56WFL300/12 Wide Flood 1/12 12 6000 1000 C-6 4.50” 35x20
PS25 Med. 401305 PS25CL300/P5 Clear Prism® Long Life Plus™ 12/60 130 3600 5000 C-9M 6.93” -
401306 PS25FR300/P5 Frost Prism® Long Life Plus™ 12/60 130 3600 5000 C-9M 6.93” -
PS30 Med. 401308 PS30CL300/P5 Clear Prism® Long Life Plus™ 12/60 130 3600 5000 C-9M 8.06” -
401310 PS30FR300/P5 Frost Prism® Long Life Plus™ 12/60 130 3600 5000 C-9M 8.06” -
PS35 Mog. 401316 PS35CL300/P5 Clear Prism® Long Life Plus™ 6/24 130 3600 5000 C-9M 9.37” -
401318 PS35FR300/P5 Frost Prism® Long Life Plus™ 6/24 130 3600 5000 C-9M 9.37” -
R40 Med. 104040 5,7,10,12,14 R40FL300/12V Flood Pool Lamp 12/24 12 3000 2000 C-6 6.56” -
104035 5,7,12,14 R40FL300/HG Flood Hard Glass 12/24 130 3000 3000 C-6 6.56” -
375 WATT
R40 Med. 104048 6,7,11,14 R40CL375 Clear Infrared Prism®12/24 120 - 5000 C-9 6.56” -
104050 6,7,11,14,16 R40CL375/CSTF CoverShield® PFA Prism®1/12 120 - 5000 C-9 6.56” -
400 WATT
G30 Med. 5508 15 400G/FL Clear 1/100 120 6800 800 C-5 5.10” -
R40 Med. 104038 5,12,14 R40FL400/HG Flood Hard Glass 12/24 120 4150 2000 CC-9 6.56” -
500 WATT
PAR56 Mog.
End
Prong
843494 X 4,13 PAR56Q500NSP Narrow Spot 1/6 120 8000 4000 CC-6 5.00” 13x8
PAR64 Mog.
End
Prong
839409 13 PAR64MFL500 Medium Flood Major 1/12 120 6500 2000 CC-13 6.00” 23x11
14938 13 PAR64NSP500 Narrow Spot Major 1/12 120 6500 2000 CC-13 6.00” 12x7
R40 Med. 104042 5,12,14 R40FL500/HG Flood Hard Glass 12/24 120 5400 2000 CC-9 6.56” -
Mog. 821734 5,12,14 R40FL500/3FL Flood Major 1/24 120 6500 2000 C-2V 7.25” -
R40
PS25
PS30
PS35
PAR56/64
End Prong G30 BR40
E Means this lamp meets Federal Minimum Efciency standards.
Incandescent lamp symbols, footnotes and abbreviations are located on pages 151-153.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 147
Decorative
INCANDESCENT LAMPS
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
3 WATT
CA5 Cand. 2502 2 CFTC3 Clear Flicker Flame 25/500 130 - 1500 - 2.88” -
CA10 Cand. 2008 2 CFC3 Clear Flicker Flame 25/500 130 - 1500 - 4.12” -
Med. 2510 2 EFC3 Clear Flicker Flame 25/500 130 - 1500 - 4.12” -
7.5 WATT
CA5 Cand. 2005 2 CFTC7.5 Clear 50/1000 130 40 1500 C-7A 2.88” -
CA8 Cand. 2000 2 CFCP7.5 Clear 25mm 25/500 130 35 2000 C-7A 3.58” -
15 WATT
B8 Cand. 1020 2 CTCP15 Clear 25mm 25/500 130 95 3000 C-7A 3.15” -
B10 Cand. 1001 2 CTC15 Clear 32mm 25/500 130 95 3000 C-7A 3.87” -
CA8 Cand. 2020 2 CFCP15 Clear 25mm 25/500 130 95 3000 C-7A 3.58” -
CA10 Cand. 2001 2 CFC15 Clear 32mm 25/500 130 95 3000 C-7A 4.12” -
G16.5 Cand. 4001 2 G16CL15 Clear 25/500 130 95 3000 C-7A 3.00” -
4015 2 G16WH15 White 25/500 130 80 3000 C-7A 3.00” -
25 WATT
B8 Cand. 1021 2 CTCP25 Clear 25mm 25/500 130 220 3000 CC-2V 3.15” -
B10 Cand. 1003 2 CTC25 Clear 32mm 25/500 130 220 3000 CC-2V 3.87” -
101280 X,N,2 CTC25/ND Clear Neodymium PureLite®10/50 120 140 5000 CC-2V 3.87” -
100192 2 CTF25 Frost 32mm 25/500 130 220 3000 CC-2V 3.87” -
E14 121023 CTC25/E14 Clear 32mm 25/500 120 220 3000 CC-2V 3.87” -
Med. 1012 2 ETC25 Clear 32mm 25/500 130 220 3000 CC-2V 3.87” -
1013 2 ETF25 Frost 32mm 25/500 130 220 3000 CC-2V 3.87” -
CA8 Cand. 2021 2 CFCP25 Clear 25mm 25/500 130 220 3000 CC-2V 3.58” -
CA10 Cand. 2003 2 CFC25 Clear 32mm 25/500 130 220 3000 CC-2V 4.12” -
2040 2,10 CFC25/12V Clear 32mm 25/500 12 200 2000 C-6 4.12” -
2004 2 CFF25 Frost 32mm 25/500 130 220 3000 CC-2V 4.12” -
Med. 2012 2 EFC25 Clear 32mm 25/500 130 220 3000 CC-2V 4.12” -
2013 2 EFF25 Frost 32mm 25/500 130 220 3000 CC-2V 4.12” -
C11 Cand. 100210 2 C11SG25 Clear Spun Glow 25/500 130 - 1500 CC-2V 4.02” -
C15 Med. 100214 2 C15SG25 Clear Spun Glow 25/500 130 - 1500 CC-2V 4.49” -
F15 Med. 3001 2 F15CL25 Clear 25/250 130 140 3000 C-9 4.50” -
3003 2 F15AMB25 Amber 25/250 130 - 3000 C-9 4.50” -
G16.5 Cand. 4002 2 G16CL25 Clear 25/500 130 220 3000 CC-2V 3.00” -
101270 X,N,2 G16CL25/ND Clear Neodymium PureLite®10/50 120 140 5000 CC-2V 3.00” -
4016 2 G16WH25 White 25/500 130 170 3000 CC-2V 3.00” -
G25 Med. 5001 G25CL25 Clear 10/100 130 150 3500 C-9 4.50” -
5002 G25WH25 White 10/100 130 140 3500 C-9 4.50” -
B10
G16.5
G19.5
G25F15
C11
C15
CA8
CA10
B8
CA5
E Means this lamp meets Federal Minimum Efciency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
148
Decorative
INCANDESCENT LAMPS
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
40 WATT
B8 Cand. 1023 2 CTCP40 Clear 25mm 25/500 130 370 3000 CC-2V 3.15” -
B10 Cand. 1006 2 CTC40 Clear 32mm 25/500 130 370 3000 CC-2V 3.87” -
1007 2 CTF40 Frost 32mm 25/500 130 370 3000 CC-2V 3.87” -
E14 121025 X, 2 CTC40/E14 Clear 32mm 25/500 130 370 3000 CC-2V 3.87” -
Med. 1015 2 ETC40 Clear 32mm 25/500 130 370 3000 CC-2V 3.87” -
102148 2 ETC40/CS Clear CoverShield®25/500 130 - 3000 CC-2V 3.87” -
1016 2 ETF40 Frost 32mm 25/500 130 370 3000 CC-2V 3.87” -
CA8 Cand. 2023 2 CFCP40 Clear 25mm 25/500 130 370 3000 CC-2V 3.58” -
CA10 Cand. 2006 2 CFC40 Clear 32mm 25/500 130 370 3000 CC-2V 4.12” -
2007 2 CFF40 Frost 32mm 25/500 130 370 3000 CC-2V 4.12” -
Med. 2015 2 EFC40 Clear 32mm 25/500 130 370 3000 CC-2V 4.12” -
2016 2 EFF40 Frost 32mm 25/500 130 370 3000 CC-2V 4.12” -
C11 Cand. 100212 2 C11SG40 Clear Spun Glow 25/500 130 - 1500 CC-2V 4.02” -
C15 Med. 100216 2 C15SG40 Clear Spun Glow 25/500 130 - 1500 CC-2V 4.49” -
100224 X, 2 C15SG40/AMB Amber Spun Glow 25/500 130 - 2000 C-9 4.49” -
F15 Med. 3004 2 F15CL40 Clear 25/250 130 300 3000 C-9 4.50” -
3006 2 F15AMB40 Amber 25/250 130 - 3000 C-9 4.50” -
G16.5 Cand. 4003 2 G16CL40 Clear 25/500 130 370 3000 CC-2V 3.00” -
4017 2 G16WH40 White 25/500 130 320 3000 CC-2V 3.00” -
G19.5 Med. 104504 X, 2 G19WH40 White 25/500 130 340 2000 C-9 3.50” -
G25 Med. 5003 G25CL40 Clear 10/100 130 300 3500 C-9 4.50” -
125003 G25CL40/120 Clear 10/100 120 300 3500 C-9 4.50” -
102380 G25CL40/SB Clear Silver Bowl Prism®10/100 130 - 3500 C-9 4.50” -
5004 G25WH40 White 10/100 130 270 3500 C-9 4.50” -
125004 X G25WH40/120 White 10/100 120 280 3500 C-9 4.50” -
G40 Med. 5203 G40CL40 Clear 6/24 130 260 5000 C-9 6.93” -
5202 G40WH40 White 6/24 130 240 5000 C-9 6.93” -
B10
G16.5
G19.5
G25
G40 F15
C11
C15
CA8
CA10 B8
E Means this lamp meets Federal Minimum Efciency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 149
Decorative
INCANDESCENT LAMPS
Bulb Base Product
Number Footnotes Product Code Description Pkg.
Qty. Volts Lumens Avg.
Life
Design
Filament MOL Beam
Spread
60 WATT
B10 Cand. 1009 2CTC60 Clear 32mm 25/500 130 650 3000 CC-2V 3.87” -
101284 X,N,2 CTC60/ND Clear Neodymium PureLite®10/50 120 500 5000 CC-2V 3.87” -
1010 2CTF60 Frost 32mm 25/500 130 640 3000 CC-2V 3.87” -
E14 121027 XCTC60/E14 Clear 32mm 25/500 120 650 3000 CC-2V 3.87” -
Med. 1018 2ETC60 Clear 32mm 25/500 130 650 3000 CC-2V 3.87” -
102146 2ETC60/CS Clear CoverShield®25/500 130 - 3000 CC-2V 3.87” -
1019 2ETF60 Frost 32mm 25/500 130 640 3000 CC-2V 3.87” -
CA10 Cand. 2009 2CFC60 Clear 32mm 25/500 130 650 3000 CC-2V 4.12” -
2010 2CFF60 Frost 32mm 25/500 130 640 3000 CC-2V 4.12” -
Med. 2018 2EFC60 Clear 32mm 25/500 130 650 3000 CC-2V 4.12” -
2019 2EFF60 Frost 32mm 25/500 130 640 3000 CC-2V 4.12” -
C11 Cand. 100213 2C11SG60 Clear Spun Glow 25/500 130 - 1500 CC-2V 4.02” -
100228 XC11SG60/AMB Amber Spun Glow 25/500 130 - 2000 CC-2V 4.02” -
C15 Med. 100218 2C15SG60 Clear Spun Glow 25/500 130 - 1500 CC-2V 4.49” -
100226 XC15SG60/AMB Amber Spun Glow 25/500 130 - 2000 C-9 4.49” -
G16.5 Cand. 4004 2G16CL60 Clear 25/500 130 650 3000 CC-2V 3.00” -
4018 2G16WH60 White 25/500 130 560 3000 CC-2V 3.00” -
G19.5 Med. 104506 2G19WH60 White 25/500 130 550 1500 C-9 3.50” -
G25 Med. 5005 G25CL60 Clear 10/100 130 550 3500 C-9 4.50” -
102382 G25CL60/SB Clear Silver Bowl 10/100 130 - 3500 C-9 4.50” -
5006 G25WH60 White 10/100 130 480 3500 C-9 4.50” -
G30 Med. 5506 G30WH60 White 10/100 130 480 5000 C-9 5.00” -
G40 Med. 5205 G40CL60 Clear 6/24 130 520 5000 C-9 6.93” -
5204 G40WH60 White 6/24 130 450 5000 C-9 6.93” -
100 WATT
G25 Med. 5007 G25CL100 Clear 10/100 130 1100 3500 C-9 4.50” -
G40 Med. 5207 G40CL100 Clear 6/24 130 1100 5000 C-9 6.93” -
5206 G40WH100 White 6/24 130 950 5000 C-9 6.93” -
G16.5
G19.5
G25
G30
G40
C11
C15CA10
B10
E Means this lamp meets Federal Minimum Efciency standards.
Incandescent lamps symbols, footnotes and abbreviations are located on pages 151-153.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
150
A
A-Shape
BR
Bulge Neck
Reector
C
Cylindrical
CA8-CA10
Candelabra
Base
B8-B10
Candelabra
Base
CA8-CA10
Edison
Base
F
Flame
B8-B10
Edison
Base
ER
Elliptical
Reector
CA5
Candelabra
Base
G
Globe
Candelabra
G
Globe
Medium
PAR36
Parabolic
Reector
PAR
Parabolic
Reector
PS
Pear
Straight
Neck
R
Reector
S
Straight
Side
T
Tubular
Screw
Terminals
Candelabra
E12
E14DC
Bayonet
BA15d
CC-2V C3-A C-5
CC indicates coiled-coil lament.
CC-6 C-7A CC-8 CC-9 C-9M CC-13
Intermediate
E17
Medium
E26
Medium
Side Prong
Mog.
E39
Mog. End
Prong
INCANDESCENT LAMPS
Bulb, Base and Filament Identication Guide
Bulb Shapes
Base Types
Filament Designations
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com 151
INCANDESCENT LAMPS
Symbols, Footnotes and Abbreviations
SYMBOLS
New product introduced within the past year.
Al Aluminum base.
NNickel-plated brass base.
rHeat-resistant glass.
$Energy saving product.
This lamp meets Federal Minimum Efciency standards.
XProduct will be discontinued when inventory is depleted.
LLegislated lamp will not be manufactured after January 1, 2014.
FOOTNOTES
1Operate base down.
2Operate base down to horizontal.
3Operate base up.
4This lamp should be shielded from moisture to prevent breakage.
5May not give satisfactory performance if accessory equipment is attached to or touches bulb.
6Do not allow hot bulb to come in contact with liquid or metal parts of the xture, as glass may shatter.
Do not use outdoors or operate near ammable materials. Operate in heat-resistant sockets.
7Do not use in equipment where base temperature will exceed 500°F.
8Use only in equipment specially designed to maintain bulb and base temperatures within safe limits.
9May be used for indoor and outdoor applications.
10 Use only in circuits supplying the voltage indicated on the lamp. Not for use in household sockets.
11
CAUTION: Do not operate near ammable material. Operate only in heat-resistant sockets.
WARNING: Use with care. May cause serious burns. The unattended use of infrared heat by children
or incapacitated persons is dangerous. Do not place closer than 18” to surface area. Do not use for
therapeutic applications unless recommended by a physician. For food warming, use only lamps with
heat-resistant glass and/or heat-resistant coating.
12 Although this bulb is made of heat-resistant glass, it may break if moisture falls on it.
Not recommended for use in enclosed and/or close-tting housing.
13 Use only with heat-resistant connector and with lamp supported by bulb rim.
14 Operate only in porcelain sockets.
15 Unsatisfactory operation if operated in positions between horizontal and base up, particularly between
45° from base up and base down.
16 Do not operate in aviaries or around fowl or small animals.
17 See Halogen footnotes 1, 2 and 7 on page 131.
18 See Halogen footnotes 1, 7 and 8 on page 131.
19 See Halogen footnotes 1 and 7 on page 131.
E
TOC
152
ABBREVIATIONS
/1 Sufx used to indicate a Clear Faceted Infrared lamp.
3W Code abbreviation for Three Way lamps.
/5 Sufx used to indicate 5,000 hour lamps.
/10 Sufx used to indicate Red-Faced Heat lamps.
/12V Sufx used to indicate 12 Volt lamps.
/20 Sufx used to indicate Prism® UltraLife® 20,000 hour lamps.
/39 Sufx used to indicate 39 Watt HaloXen® PAR lamps.
/120 Sufx used to indicate 120 Volt lamps.
/130 Sufx used to indicate 130 Volt HaloXen® PAR lamps.
/145V Sufx used to indicate 145 Volt lamps.
/1750 Sufx used to indicate lamps that produce 1750 lumens.
/CAN Sufx used to indicate lamps with Candelabra (E12) base.
/E12 Sufx used to indicate lamps with an E12 (candleabra) base.
/E14 Sufx used to indicate lamps with an E14 base.
/E17 Sufx used to indicate lamps with an E17 (intermediate) base.
/E26 Sufx used to indicate lamps with an E26 (medium) base.
AMB Code abbreviation for lamps with an Amber nish.
BG Code abbreviation for Bug Light lamps.
BLU Code abbreviation for lamps with a Blue nish.
CCode abbreviation for lamps with a Ceramic color nish.
CL Code abbreviation for lamps with a Clear nish.
/CS Sufx used to indicate CoverShield® safety coated lamps.
/CSTF Sufx used to indicate CoverShield® PFA safety coated lamps.
DC Code abbreviation for lamps with a Double Contact Bayonet base (BA15d).
DPNK Code abbreviation for lamps with a Dawn Pink nish.
FL Code abbreviation for Flood lamps.
FR Code abbreviation for lamps with a Frost nish.
GRN Code abbreviation for lamps with a Green nish.
GRO Code abbreviation for Plant Grow lamps.
/HG Sufx used to indicate Hard Glass lamps.
HP Code abbreviation for Halogen PAR lamps.
INCANDESCENT LAMPS
Symbols, Footnotes and Abbreviations
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
153
INCANDESCENT LAMPS
Symbols, Footnotes and Abbreviations
ABBREVIATIONS
/HX Sufx used to indicate HaloXen® lamps.
INT Code abbreviation for lamps with an Intermediate (E17) base.
LCode abbreviation for Long Neck Halogen PAR30 lamps.
/M Sufx used to indicate Major brand lamps (GE, Philips, Osram/Sylvania).
MED Code abbreviation for lamps with a Medium (E26/27) base.
MFL Code abbreviation for Medium Flood lamps.
NCode abbreviation for High-Intensity lamps.
/ND Sufx used to indicate PureLite® Natural Daylight lamps.
NFL Code abbreviation for Narrow Flood lamps.
/NL Sufx used to indicate Night Light.
NSP Code abbreviation for Narrow Spot lamps.
ORG Code abbreviation for lamps with an Orange nish.
/P5 Sufx used to indicate Prism® Long Life Plus® 5,000 Hour staggered support C-9M lament lamps.
/P10 Sufx used to indicate Prism® Ultra Life® 10,000 Hour staggered support C-9M lament lamps.
PNK Code abbreviation for lamps with a Pink nish.
PUR Code abbreviation for lamps with a Purple nish.
QCode abbreviation for Quartz Halogen lamps.
RED Code abbreviation for lamps with a Red nish.
RS Code abbreviation for Rough Service lamps.
/S Code abbreviation for HaloXen® Silver PAR lamps.
/SB Sufx used to indicate Silver Bowl.
SG Code abbreviation for Spun Glow decorative lamps.
SP Code abbreviation for Spot lamps.
SW Code abbreviation for lamps with a Soft White nish.
/T Sufx used for colored Incandescent lamps with a Transparent nish.
VNSP Code abbreviation for Very Narrow Spot lamps.
VWFL Code abbreviation for Very Wide Flood lamps.
WFL Code abbreviation for Wide Flood lamps.
WH Code abbreviation for lamps with a White nish.
XIR Sufx used to indicate Halogen Infrared lamps.
YEL Code abbreviation for lamps with a Yellow nish.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOC
CONTENTS
156
157
157
157
158
158
159
161
164
165
166
167
How to Read a Table
Safety Coated Metal Halide Lamps
Safety Coated Incandescent Lamps
Safety Coated Halogen Lamps
Safety Coated Compact Fluorescent Lamps
Safety Coated Linear Fluorescent Lamps
Photo/Projection/SSTV Lamps
Miniature Lamps
Sealed Beam Lamps
Accessories
Bulb, Base and Filament Identication
Symbols, Footnotes and Abbreviation
SPECIALTY LAMPS
®
main
TOC
BULB
Designations indicate shape
and size. Illustrations can
be found on page 166 and
at the top of each page.
BASE
Indicates base type.
Full base descriptions
and illustrations can be
found on page 166.
PACKAGE QUANTITY
Indicates minimum sell quantity
and smallest shipping carton.
ANSI
CODE
The specic
electrical
characteristics
of a lamp.
PRODUCT
CODE
Abbreviated product
description can also
be used for ordering.
A key to abbreviations
can be found on
page 168.
PRODUCT
NUMBER
Use this product
number when
placing an order.
FILAMENT
Filament types
are illustrated
on page 166.
FOOTNOTES &
SYMBOLS
Related footnotes can
be found on page 167.
VOLTS
Indicates the
product’s design
voltage of operation.
MOL
Indicates
maximum
overall
length in
inches.
LUMENS
The lamp’s average
light output at 40%
of rated life.
AVERAGE
LIFE
Average rated
life expressed
in hours.
COLOR
TEMP.
A term used to
describe the
color of a light
source and is
expressed in
degrees
“Kelvin” (K).
HOW TO READ A SPECIALTY LAMP TABLE
Bulb Base Watts Product
Number Footnotes Product
Code Description Pkg.
Qty. ANSI Color
Temp. Lumens Avg.
Life MOL
Metal Halide
ED28 Mog. 250 108604 6,9,12,13,14,15 MH250/U/CSTF Clear PFA 1/12 M58/E 4000 21800 10000 8.25”
ED37 Mog. 400 108600 6,8,9,12,13,14,15 MH400/U/CSTF Clear PFA 1/6 M59/E 4000 36000 20000 11.50”
EX39 400 60502 7,8,9,10,11,15 MP400/BU/CSTF Clear Base Up PFA 1/6 M59/O 4000 36000 20000 11.50”
Photo/Projection/SSTV
ETH Frosted/T4 E11 150 120 1/10 2000 CC-8 2700 2900 U
*EVW MR16 GY5.3 250 82 1/10 50 CC-8 - 3300 BDTH
*EXR MR13 GX5.3 300 82 1/10 35 CC-8 - 3350 BDTH
®
ANSI
Code Bulb Base Watts Volts Pkg.
Qty.
Avg.
Life Filament Lumens Color
Temp.
Operating
Position
DESCRIPTION
Bulb nish and other
important information.
OPERATING
POSITION
Indicates the
approved
operating positon
of a lamp.
TOC
157
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.
SPECIALTY LAMPS
Incandescent
A15 Med. 40 90300 A15CL40/CSTF Clear PFA 20/120 300 3000 3.50”
40 6146 A15RS40/CS Clear 20/120 300 1500 3.50”
60 6147 A15RS60/CS Clear 20/120 500 1500 3.50”
A19 Med. 25 101124 A19RS25/CS Clear 20/120 160 2000 4.25”
40 101125 A19RS40/CS Clear 20/120 300 2000 4.25”
60 6141 A19RS60/CS Clear 20/120 500 2500 4.25”
75 6142 A19RS75/CS Clear 20/120 680 2000 4.25”
100 6143 A19RS100/CS Clear 20/120 960 2500 4.25”
A21 Med. 100 6041 A21RS100/P5/CS Clear 12/60 800 5000 5.00”
150 6043 A21RS150/P5/CS Clear 1/60 1300 5000 5.00”
B10 Med. 40 102148 16 ETC40/CS Clear 25/500 370 3000 3.87”
60 102146 16 ETC60/CS Clear 25/500 650 3000 3.87”
BR30 Med. 65 404051 18 BR30FL65/CS Flood 1/24 580 5000 5.37”
BR40 Med. 120 404065 18 BR40FL120/5/CS Flood 1/24 1200 5000 6.56”
125 90320 BR40CL125/1/CSTF Clear Heat PFA 1/12 - 6000 6.56”
250 404066 18,20,22 BR40CL250/1/CSTF Clear Heat PFA 1/12 - 5000 6.56”
PS25 Med. 150 401345 17 PS25CL150/P5/CS Clear 1/60 1300 5000 6.93”
200 401347 17 PS25CL200/P5/CS Clear 1/60 2000 5000 6.93”
R12 BA15s 20 1383/CS 1383/CS S.C. Bayonet 13V 10/1000 - 300 2.60”
R20 Med. 30 10102 R20FL30/CS Flood 10/100 140 3000 3.93”
50 104016 R20FL50/CS Flood 10/100 210 2000 4.80”
R40 Med. 250 404071 18,20,21 R40RED250/10/CSTF Red Heat PFA 1/12 - 5000 6.56”
375 104050 15,18,19,20,21 R40CL375/CSTF Clear Heat PFA 1/12 - 5000 6.56”
T10 Med. 40 106228 T10CL40/CS Clear 25/200 280 2500 5.00”
Halogen
ALR BA15d 20 90351 GBF/CS Flood Frosted 12V 1/50 750cp 2000 1.46”
Bulb Base Watts Product
Number Footnotes Product
Code Description Pkg.
Qty. ANSI Color
Temp. Lumens Avg.
Life MOL
Metal Halide
ED28 Mog. 250 108604 6,9,12,13,14,15 MH250/U/CSTF Clear PFA 1/12 M58/E 4000 21800 10000 8.25”
ED37 Mog. 400 108600 6,8,9,12,13,14,15 MH400/U/CSTF Clear PFA 1/6 M59/E 4000 36000 20000 11.50”
EX39 400 60502 7,8,9,10,11,15 MP400/BU/CSTF Clear Base Up PFA 1/6 M59/O 4000 36000 20000 11.50”
A15
A19
A21 B10
BR30
BR40 PS
R12
R20 R40 ALRT10
ED37
ED28
Bulb Base Watts Product
Number Footnotes Product
Code Description Pkg.
Qty. Lumens Avg.
Life MOL
Safety Coated
TOC
Safety Coated
158
Bulb Base Watts Product
Number Footnotes Product
Code Description Pkg.
Qty. ANSI Color
Temp. Lumens Avg.
Life MOL
SPECIALTY LAMPS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
®
R30 T5
Miniature Bi-Pin
T8/T12
Medium Bi-Pin
Compact Fluorescent
R30 Med. 16 46106 X 1,2,4 CFL16/50/R30/CS Natural White Flood 6/24 5000 82 750 8000 5.56”
Linear Fluorescent
T5 Min.
Bi-Pin
28 90015 X E 4,5 F28T5/835/ECO/IC/CS 835 Phosphor 25 3500 86 2900 24000 46”
28 90016 X E 4,5 F28T5/841/ECO/IC/CS 841 Phosphor 25 4100 86 2900 24000 46”
54 90051 E 4,5 F54T5/835/HO/ECO/IC/CS 835 Phosphor High Output 25 3500 86 5000 24000 46”
54 90052 E 4,5 F54T5/841/HO/ECO/IC/CS 841 Phosphor High Output 25 4100 86 5000 24000 46”
54 90053 E 4,5 F54T5/850/HO/ECO/IC/CS 850 Phosphor High Output 25 5000 86 5000 24000 46”
T8 Med.
Bi-Pin
28 90081 X E 4 F28T8/835/ECO/IC/CS 835 Phosphor 25 3500 86 2800 24000 48”
32 90084 E 4 F32T8/735/ECO/CS 735 Phosphor 25 3500 78 2850 24000 48”
32 90085 E 4 F32T8/741/ECO/CS 741 Phosphor 25 4100 78 2850 24000 48”
32 90089 E 4 F32T8/750/ECO/CS 750 Phosphor 25 5000 78 2850 24000 48”
32 90094 E 4 F32T8/835/ECO/CS 835 Phosphor 25 3500 86 3050 24000 48”
32 90095 E 4 F32T8/841/ECO/CS 841 Phosphor 25 4100 86 3050 24000 48”
32 90096 E 4 F32T8/850/ECO/CS 850 Phosphor 25 5000 86 3050 24000 48”
Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.
TOC
Photo/Projection/SSTV
159
Specialty laMpS
ANSI
Code Bulb Base Watts Volts Pkg.
Qty.
Avg.
Life Filament Lumens Color
Temp.
Operating
Position
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Photo/Projection/SSTV
DVS T3 R7s 500 130 1/10 2000 C-8 9500 3000 HOR
*DWE PAR36 Screw Terminals 650 120 1/12 100 C-6 24000 3200 U
*DYS/DYV/BHC/5 G7 GZ9.5 600 125 1/10 150 CC-6 17000 3200 HOR
*EGE T4.25 P28s 500 120 1/10 2000 CC-8 10450 2950 U
EHM T3 R7s 300 120 1/10 2000 C-8 5000 2950 HOR
EHT T4 E11 250 120 1/10 2000 CC-8 4500 2950 U
*EHV T4 E11 325 120 1/10 500 CC-8 7800 3000 U
EJA MR16 GX5.3 150 21 1/10 40 CC-6 - 3400 BDTH
*EJL MR16 GX5.3 200 24 1/10 50 CC-6 - 3400 BDTH
*EJM MR16 GX5.3 150 21 1/10 40 CC-6 - 3350 BDTH
EJV MR16 GX5.3 150 21 1/10 40 CC-8 - 3350 BDTH
EKE MR16 GX5.3 150 21 1/10 200 CC-6 - 3250 BDTH
ELC MR16 GX5.3 250 24 1/10 50 CC-6 - 3400 BDTH
*ENH MR16 GY5.3 250 120 1/10 175 CC-8 - 3250 BDTH
*ENX MR16 GY5.3 360 82 1/10 75 CC-8 - 3300 BDTH
*ENX/5 MR16 GY5.3 360 86 1/10 100 CC-8 - 3300 BDTH
*ESD MR16 GY5.3 150 120 1/10 12 CC-8 - 3350 BDTH
*ESL T4 E11 150 120 1/10 1000 CC-2V 2800 2900 U
*ESM Frosted/T4 E11 250 120 1/10 2000 CC-8 4850 2950 U
*ESN T4 E11 100 120 1/10 750 CC-2V 1900 2850 U
*ESP T4 BA15d 150 120 1/10 1000 CC-2V 2400 2950 U
*ESR T4 BA15d 100 120 1/10 1000 CC-2V 1900 3000 U
*ESS T4 BA15d 250 120 1/10 2000 CC-8 5000 3000 U
*ETB Frosted/T4 BA15d 250 120 1/10 2000 CC-8 4700 2950 U
ETC T4 BA15d 150 20 1/10 2000 CC-8 2800 2900 U
*ETD Frosted/T4 BA15d 100 120 1/10 750 CC-2V 1750 2900 U
*ETE Frosted/T4 E11 100 120 1/10 750 CC-2V 1750 2900 U
ETF Frosted/T4 BA15d 150 120 1/10 2000 CC-8 2700 2900 U
*ETG T4 E11 150 120 1/10 2000 CC-8 2400 2950 U
®
T7 T4.25
T4
BA15d
T4
E11 G7 T3
MR16
GY5.3
PAR36
* Item will be discontinued when inventory is depleted.
Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.
TOC
Photo/Projection/SSTV
160
SPECIALTY LAMPS
ANSI
Code Bulb Base Watts Volts Pkg.
Qty.
Avg.
Life Filament Lumens Color
Temp.
Operating
Position
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Photo/Projection/SSTV continued
ETH Frosted/T4 E11 150 120 1/10 2000 CC-8 2700 2900 U
*EVW MR16 GY5.3 250 82 1/10 50 CC-8 - 3300 BDTH
*EXR MR13 GX5.3 300 82 1/10 35 CC-8 - 3350 BDTH
*EXR/5 MR13 GX5.3 300 86 1/10 70 CC-8 - 3350 BDTH
*EXY MR13 GX5.3 250 82 1/10 200 CC-8 - 3200 BDTH
*EYA MR16 GY5.3 200 82 1/10 50 CC-8 - 3300 BDTH
*EYB T3.5 G5.3 360 82 1/10 75 CC-8 10000 3300 BDTH
*EYB/5 T3.5 G5.3 360 86 1/10 150 CC-8 10000 3300 BDTH
EYV Frosted/T4 E11 500 130 1/10 2000 CC-8 8075 3000 U
EYW T4 E11 500 130 1/10 2000 CC-8 8500 3000 U
*FAL T4 R7s 420 120 1/10 90 CC-8 11000 3200 U
*FBO PAR36 Screw Terminals 650 120 1/12 100 C-6 38000 3400 U
*FCL T3 R7s 500 120 1/10 2000 C-8 9500 3000 HOR
*FCM T3 R7s 1000 120 1/10 300 C-8 27000 3200 HOR
*FCR T3.5 GY6.35 100 12 1/10 50 C-6F 2900 3250 BDTH
FCS T4 G6.35 150 24 1/10 50 C-6F 4500 3400 ANY
*FEL T6 G9.5 1000 120 1/10 300 CC-8 27000 3200 BDTH
*FHM Frosted/T3 R7s 1000 120 1/10 300 C-8 26000 3200 HOR
*FHS MR13 GX5.3 300 82 1/10 70 CC-8 - 3300 BDTH
*FHS/5 MR13 GX5.3 300 86 1/10 140 CC-8 - 3300 BDTH
FLK T6 G9.5 575 115 1/10 300 CC-8 16000 3200 U
*GBE ALR12 BA15d 20 12 1/10 2000 CC-8 1500cp 3000 U
GBF ALR12 BA15d 20 12 1/10 2000 CC-8 750cp 3000 U
GBF/CS ALR12 BA15d 20 12 1/10 2000 CC-8 750cp 3000 U
H111 MR16 GX5.3 200 19.7 1/100 500 CC-8 - 3000 BDTH
®
ALR
MR16
MR13
GY5.3
T6
G9.5
PAR36 T3.5
T4
E11
T3
* Item will be discontinued when inventory is depleted.
Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Miniatures
161
Specialty laMpS
Product
Code Bulb Base Primary
Application Volts Amps or
Watts
Pkg.
Qty. MSCP Avg.
Life
Design
Filament MOL
T1.75
S.C. Midget
Flanged
T2.5
BA9s
T3.25
BA9s
Miniatures
55 G4.5 BA9s Indicator 7 0.41 10/2000 2 500 C-2R 1.07”
*57 G4.5 BA9s Auto, Instrument 14 0.24 10/2000 2 500 C-2V 1.07”
73 T1.75 Wedge Indicator 14 0.08 10/2000 0.3 15000 C-2V 0.80”
*74 T1.75 Wedge Auto 14 0.10 10/2000 0.7 1000 C-2V 0.80”
85 T1.75 Wedge Indicator 28 0.04 10/2000 0.3 7000 C-2F 0.80”
*86 T1.75 Wedge Indicator 6.3 0.20 10/2000 0.4 20000 C-2V 0.80”
*89 G6 BA15s Auto 13 0.58 10/2000 6 750 C-2R 1.40”
93 S8 BA15s Auto 12.8 1.04 10/2000 15 700 C-6 2.00”
94 S8 BA15d Auto, Marine 12.8 1.04 10/2000 15 700 C-6 2.00”
120MB/M T2.5 BA9s Tel. Indicator 120 0.025 10/100 0.36 10000 CC-3A 1.20”
130MB T2.5 BA9s Indicator 130 0.025 10/2000 0.36 10000 CC-3A 1.19”
*159 T3.25 Wedge Indicator 6.3 0.15 10/2000 0.34 5000 C-2R 1.06”
161 T3.25 Wedge Auto, Instrument 14 0.19 10/2000 1 4000 C-2F 1.06”
194 T3.25 Wedge Auto 14 0.27 10/2000 2 2500 C-2F 1.10”
*259 T3.25 Wedge Radio 6.3 0.25 10/2000 0.65 5000 C-2R 1.06”
*313 T3.25 BA9s Aircraft 28 0.17 10/2000 3.5 500 C-2F 1.19”
*316 T3.25 BA9s Aircraft 6 0.70 10/2000 3.4 500 C-2R 1.19”
*400 T3.25 Wedge Aircraft 28 0.10 10/2000 1.6 1000 C-2F 1.06”
*456 G4.5 BA9s Instrument 28 0.17 10/2000 2 5000 C-2F 1.07”
464 T3.25 Wedge Aircraft 28 0.17 10/2000 3 1500 C-2F 1.06”
555 T3.25 Wedge Pinball 6.3 0.25 10/2000 0.9 3000 C-2R 1.06”
590 T3.25 Wedge Strip Lighting 13.5 0.37 10/2000 4 300 C-2V 1.06”
656 T3.25 Wedge Indicator 28 0.06 10/2000 0.62 2500 C-2F 1.06”
657 T3.25 Wedge Indicator 28 0.08 10/2000 0.62 15000 C-2F 1.06”
658 T3.25 Wedge Indicator 14 0.08 10/2000 0.31 15000 C-2F 1.06”
755 T3.25 BA9s Indicator 6.3 0.15 10/2000 0.33 20000 C-2R 1.20”
756 T3.25 BA9s Indicator 14 0.08 10/2000 0.31 15000 C-2F 1.19”
757 T3.25 BA9s Indicator 28 0.08 10/2000 0.62 15000 C-2F 1.19”
904 T5 Wedge Auto 13.5 0.69 10/2000 4 5000 C-2F 1.50”
906 T5 Wedge Auto 13.0 0.69 10/2000 6 1000 C-2F 1.50”
909 T5 Wedge Emergency Lighting 6.0 0.62 10/2000 3 50 C-2R 1.50”
912 T5 Wedge Auto 12.8 1.00 10/2000 12 1000 C-2R 1.50”
T3.25
T5
Wedge
* Item will be discontinued when inventory is depleted.
Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Miniatures
162
Specialty laMpS
Product
Code Bulb Base Primary
Application Volts Amps or
Watts
Pkg.
Qty. MSCP Avg.
Life
Design
Filament MOL
S8
BA15dT2.5T2T1.75T3.25
RP11
BA15s
Miniatures continued
912x Xenon T3.25 Wedge Garden 12.8 1.00 10/600 12 10000 C-2R 1.50”
918 T5 Wedge Garden 12.8 0.56 10/2000 6.5 500 C-2R 1.50”
918x Xenon T3.25 Wedge Garden 12.8 0.56 10/600 6.5 10000 C-2R 1.50”
921 T5 Wedge Auto 12.8 1.40 10/2000 21 500 C-2R 1.50”
921x Xenon T3.25 Wedge Auto 12.8 1.4 10/600 21 10000 C-2R 1.50”
1141 S8 BA15s Auto 12.8 1.44 10/2000 21 1000 C-6 2.00”
1142 S8 BA15d Auto 12.8 1.44 10/2000 21 1000 C-6 2.00”
1156 S8 BA15s Auto, Stop 12.8 2.10 10/2000 32 1200 C-6 2.00”
1195 RP11 BA15s Auto 12.5 3.00 10/500 50 300 C-2V 2.30”
*1196 RP11 BA15d Auto 12.5 3 10/500 50 300 C-2R 2.25”
*1229 S8 BA15d Emergency Lighting 40 0.38 10/1000 15 400 C-2V 2.00”
*1317 B6 BA15s Aircraft, Emergency 6 0.51 10/1000 3.4 100 C-6 1.75”
1383 R12 BA15s Aircraft, Reading 13 20 10/1000 - 300 C-8 2.60”
1383/CS R12 BA15s Aircraft, Reading 13 20 10/1000 - - C-8 2.60”
*1460X S8 D.C. Pre-Focus Microscope 6.5 2.75 10/500 23 100 C-6 2.00”
*1493 S8 BA15d Microscope 6.5 2.75 10/1000 23 100 C-6 2.00”
*1495 T4.5 BA9s Aircraft 28 0.30 10/1000 6 500 C-2F 1.38”
*1591 S8 BA15s Aircraft 25 0.61 10/1000 15 1000 C-2V 2.00”
1612 S8 BA15d Instrument 5.4 1.9 10/1000 10 1000 C-6 2.00”
*1619 S8 BA15s Instrument 6.7 1.90 10/1000 15 500 C-6 2.00”
1630 S8 D.C. Pre-Focus Instrument 6.5 2.75 10/500 23 100 C-6 2.00”
*1638 S8 BA15d Marine 28 1.02 10/1000 32 500 2C-6 2.00”
*1680 S8 BA15s Aircraft 6 4.10 10/1000 32 300 C-6 2.00”
*1680X S8 BA15s Aircraft 6 4.10 10/1000 32 300 C-6 2.00”
*1691AF S8 BA15s Aircraft, Frosted 28 0.61 10/1000 - 1000 2C-2R 2.00”
*1777 S8 BA15s Aircraft 12.8 1.52 10/1000 26 400 C-2R 2.00”
*1813 T3.25 BA9s Radio 14.4 0.10 10/2000 0.86 1000 C-2V 1.20”
1818 T3.25 BA9s Aircraft 24 0.17 10/2000 3.3 250 C-2F 1.20”
1819 T3.25 BA9s Indicator 28 0.04 10/2000 0.34 2500 C-2F 1.20”
1820 T3.25 BA9s Indicator 28 0.10 10/2000 1.6 1000 C-2F 1.20”
*1822 T3.25 BA9s Inidcator 36 0.10 10/2000 2.1 1000 C-2F 1.20”
*1828 T3.25 BA9s Indicator 37.5 0.05 10/2000 0.65 3000 C-2F 1.20”
R12
T5
Wedge
* Item will be discontinued when inventory is depleted.
Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Miniatures
163
Specialty laMpS
Product
Code Bulb Base Primary
Application Volts Amps or
Watts
Pkg.
Qty. MSCP Avg.
Life
Design
Filament MOL
S11
S8
Wedge T3.25
Miniatures continued
1829 T3.25 BA9s Indicator 28 0.07 10/2000 1 1000 C-2F 1.20”
1835 T3.25 BA9s Indicator 55 0.05 10/2000 1.1 5000 C-2F 1.20”
*1864 T3.25 BA9s Aircraft 28 0.17 10/2000 3 1500 C-2F 1.20”
*1866 T3.25 BA9s Radio 6.3 0.25 10/2000 0.65 5000 C-2R 1.20”
*2232 S8 BA15s Aircraft 28 0.64 10/1000 18 2000 CC-8 2.00”
*2233 S8 BA15s Aircraft 28 0.77 10/1000 21 2000 CC-8 2.00”
*3011 S11 BA15s Aircraft 28 1.29 10/500 44 1000 C-2V 2.38”
3156 S8 Plastic Wedge Auto, Stop 12.8 2.10 10/2000 32 1200 C-6 2.10”
3155K S8 Plastic Wedge Auto, Signal 12.8 1.60 10/2000 21 5000 C-6 2.10”
3156K S8 Plastic Wedge Auto, Stop 12.8 2.10 10/2000 32 5000 C-6 2.10”
*18S11/1SC S11 BA15s Railway Signal 10 18W 10/500 360lm 2000 CC-6 2.37”
*25S11/4SC S11 BA15s Railway Signal 10 25W 10/500 200lm 1000 CC-6 2.37”
S8
BA15s
* Item will be discontinued when inventory is depleted.
Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.
TOC
Sealed Beam
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
164
Specialty laMpS
Product
Code Bulb Base Volts Watts Pkg.
Qty. CBCP Avg.
Life
Design
Filament
Beam
Spread MOL
Sealed Beam
*4405 PAR36 Screw Terminals 12.8 30 1/12 50000 100 C-6 6 2.75”
4406 PAR36 Screw Terminals 12.8 35 1/12 600 300 C-6 80 2.75”
4411 PAR36 Screw Terminals 12.8 35 1/12 3000 300 C-6 - 2.75”
4414 PAR36 Screw Terminals 12.8 18 1/12 1500 300 C-6 50 2.75”
4415 PAR36 Screw Terminals 12.8 35 1/12 9000 300 C-6 40 2.75”
4446 PAR36 Screw Terminals 12.8 25 1/12 400 300 C-6 80 2.75”
4505 PAR36 Screw Terminals 28 50 1/12 45000 400 C-6 5 2.75”
*4509 PAR36 Screw Terminals 13 100 1/12 110000 25 C-6 12x6 2.75”
4515 PAR36 Screw Terminals 6.4 30 1/12 55000 100 C-6 7x6 2.75”
H4515 PAR36 Screw Terminals 6.4 30 1/12 65000 100 C-6 7x6 2.75”
*4535 PAR46 Screw Terminals 6.4 30 1/12 95000 100 C-6 5.5 4.00”
4545 PAR56 Screw Terminals 12 100 1/12 225000 100 C-6 9 5.00”
*4552 PAR64 Screw Terminals 28 250 1/6 500000 25 CC-8 7x8 6.00”
*4553 PAR46 Screw Terminals 28 250 1/12 300000 25 CC-8 11x12 4.00”
*4559 PAR64 Screw Terminals 28 600 1/6 600000 25 C-6 11x12 6.00”
*4587 PAR36 Screw Terminals 28 250 1/12 40000 25 CC-8 40 2.75”
*4596 PAR36 Screw Terminals 28 250 1/12 150000 25 CC-8 11x12 2.75”
7613 PAR36 Screw Terminals 6 8 1/12 400 50 C-6 30 2.75”
7613-1 PAR36 Slip-on Terminals 6 8 1/6 400 50 C-6 30 2.75”
PAR46/56/64
PAR36
Sealed Beam
* Item will be discontinued when inventory is depleted.
Specialty lamp symbols, footnotes and abbreviations are located on pages 167-168.
TOC
165
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Specialty laMpS
Product
Number
Product
Code Description Terminal Pkg.
Qty. Lead Length
Tube Guards
91020 TG32T8CL 4’ T8 Clear Tube Guard with Endcap - 48 -
91021 TG40T12CL 4’ T12 Clear Tube Guard with Endcap - 24 -
91022 TG96T8CL 8’ T8 Clear Tube Guard with Endcap - 48 -
91023 TG96T12CL 8’ T12 Clear Tube Guard with Endcap - 24
Adapters
91001 ADP/E26/GU24 Locking Adapter E26 to GU24 - 1/200 -
91002 ADP/E39/E26 Porcelain Adapter E39 to E26 - 1/200 -
Extenders
91000 ADP/E26/E26 Porcelain Extender E26 - 1/200 -
Sockets
91010 SKT/E39/4KV Mog. Base Porcelain Pulse Rated HID Socket 4KV Screw 1/100 10”
91011 SKT/E26/4KV Medium Base Porcelain Pulse Rated HID Socket 4KV Screw 25/200 18”
Accessories
TOC
166 Halco Lighting Technologies | 800.677.3334 | halcolighting.com
SPECIALTY LAMPS
Bulb, Base and Filament Identication Guide
Bulb Shapes
Base Types
Filament Designations
G6ALR G7 PAR36 PAR64 PAR46/56/64 MR16 RP11
S8
BA15d T1.75 T2 T2.5 T3.25 T3.25/T5
T4
E11 T4 T4.25 T5/T6 T6 T7T3
E11
Mini-Can
E12 E17 E26
Medium
G4 G6.35
G5.3/GX5.3 G9.5/GZ9.5 P28s
Medium
Prefocus
R7s SC Bayonet
BA15s
DC Bayonet
BA15d
CC indicates coiled-coil lament.
C-2F C-2R C-2V
CC-2V
C-6
CC-6
CC-7A C-8
CC-8
SC Midget
Flanged
SC Miniature
Bayonet BA9s
Screw
Terminals
Slip
Terminals
Slide #5 Plastic
Wedge
Wedge
R12
S8
BA15s
TOC
167
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Specialty laMpS
Symbols, Footnotes and Abbreviations
SYMBOLS
EThis lamp meets Federal Minimum Efciency standards.
ProLume® Eco-Shield® Low-Mercury Fluorescent lamps pass the Federal TCLP for hazardous wastes.
X Product will be discontinued when inventory is depleted.
FOOTNOTES
1
Indoor use only. Outdoor use requires weather-protected xture. All self-ballasted lamps meet part 18 of the FCC rules.
These products may cause interference with AM radios, cordless telephones and remote control devices. If interference
continues, move the lamp away from the device or plug into a different outlet.
2
ProLume® lamps with an integrated electronic ballast designed for 120-volt operation. Lamps operated at a higher voltage
or in recessed or enclosed xtures will have reduced life. Do not use with dimmers. Before using with photocell or
electronic timing devices, check device for compatibility with compact uorescent lamps. Use with incompatible devices
will result in premature lamp failure. These products are UL listed.
3UL approved for totally enclosed xtures with a maximum ballast case temperature of 90°C for GU24 base lamps, 75°C
for medium base lamps.
4Average life under specied test conditions with lamps turned off and restarted every three hours.
Lamp life is longer if lamps are started less frequently.
5Lamp designed for use with Programmed Start ballast. Lamp operates at 170mA.
Minimum starting temperature is -15°F, with peak operating temperature at 95°F.
6Lamps classied as E-type are used ONLY in suitably enclosed luminaries. See lamp warning.
7Lamps classied as O-type comply with ANSI standard C78.387 for containment testing and may be used in open
luminaries. See lamp warning.
820,000 average rated life based on 10hrs/start. 30,000 average rated life based on 120 hrs/start.
9
Color characteristics may vary somewhat from one lamp to another. Time should be allowed for lamp to stabilize in color
when it is turned on for the rst time or if for any reason its operating position is changed. This may require several hours
of operation, with more than one start. Lamp color and output may change temporarily if the lamp is subjected to excess
vibration or shock. Lamp color characteristics may change after long accumulated operating time.
10 Use with 4000 Volt pulse-rated sockets only.
11 Performance may not be satisfactory unless operated within specied operating positions.
12
Requires ballast that is designed to operate all popular brands of metal halide lamps.
1000W types will operate from H36 conventional lag type ballast for Mercury Vapor lamps at ambient
temperatures of 50°F or higher. 1000W types must not be operated at 1500W or higher.
13 Rated average life: vertical ±15°. Other positions 75% of rated life.
14 In general, horizontal lumens will be 5-10% lower than the vertical lumen values.
15 Do not operate in aviaries or around fowl or small animals.
TOC
168 Halco Lighting Technologies | 800.677.3334 | halcolighting.com
SPECIALTY LAMPS
Symbols, Footnotes and Abbreviations
FOOTNOTES
16 Operate base down to horizontal.
17 Operate base up.
18 Do not allow hot bulb to come in contact with liquid or metal parts of the xture, as glass may shatter.
Do not use outdoors or operate near ammable materials. Operate in heat-resistant sockets.
19 Do not use in equipment where base temperature will exceed 500°F.
20
CAUTION: Do not operate near ammable material. Operate only in heat-resistant sockets.
WARNING: Use with care. May cause serious burns. The unattended use of infrared heat by children
or incapacitated persons is dangerous. Do not place closer than 18” to surface area. Do not use for
therapeutic applications unless recommended by a physician. For food warming, use only lamps with
heat-resistant glass and/or heat-resistant coating.
22 Operate only in porcelain sockets.
ABBREVIATIONS
/735 Sufx used to indicate lamps with CRI of 70+ and color temperature of 3500K.
/741 Sufx used to indicate lamps with CRI of 70+ and color temperature of 4100K.
/750 Sufx used to indicate lamps with CRI of 70+ and color temperature of 5000K.
/835 Sufx used to indicate lamps with CRI of 80+ and color temperature of 3500K.
/841 Sufx used to indicate lamps with CRI of 80+ and color temperature of 4100K.
/850 Sufx used to indicate lamps with CRI of 80+ and color temperature of 5000K.
/BA15s Sufx used to indicate lamps with a BA15s (Single Contact) base.
BU Code abbreviation for Base Up Operating lamps.
CL Code abbreviation for a Clear lamp.
/CS Sufx used to indicate CoverShield® safety coated lamps.
/CSTF Suffix used to indicate CoverShield® PFA safety coated lamps.
CW Code abbreviation for Cool White lamps.
DX Code abbreviation for Daylight lamps.
/ECO Suffix used to indicate Eco-Shield® TCLP compliant lamps.
/ES Suffix used to indicate Energy Saving Fluorescent lamps.
/FL Suffix used to indicate Flood lamps.
/HO Suffix used to indicate High Output lamps.
/IC Suffix used to indicate ProLume® Industrial/Commercial service lamps.
/P5 Suffix used to indicate Prism® Long Life Plus® 5,000 Hour staggered support C-9M filament lamps.
RED Code abbreviation for a Red Heat lamp.
UCode abbreviation for Universal Metal Halide lamps.
TOC
ELECTRONIC FLUORESCENT BALLASTS
CONTENTS
172
173
178
180
193
195
200
201
202
How to Read a Table
T5 Ballasts
T5 Circline Ballasts
T8 Ballasts
T9 Circline Ballasts
T12 Ballasts
Cross Reference Guide
®
main
TOC
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp.
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
F28T5
1
28 PS 120 50166 EP228PS/MV 0.28 33 0.98 1.05 <10 0°F 1-10 J 16.90” 16.00” 1.20” 1.00”
28 PS 277 50166 EP228PS/MV 0.13 33 0.98 1.05 <10 0°F 1-24 J 16.90” 16.00” 1.20” 1.00”
28 PS 120 52112 EP228PS/MV/MC 0.29 31 0.98 1.05 <10 0°F 1-24 F 9.50” 8.90” 1.30” 1.10”
28 PS 277 52112 EP228PS/MV/MC 0.12 31 0.98 1.05 <10 0°F 1-10 F 9.50” 8.90” 1.30” 1.10”
HOW TO READ AN ELECTRONIC FLUORESCENT
BALLAST TABLE
BALLAST
FACTOR
Ratio of the lamp’s lumen
output on the specied
ballast to the lamp’s lumen
output when operated by a
reference ballast.
WIRING
DIAGRAM
References the
wiring diagram
to use.
INPUT
POWER
Total power
input to the
ballast which
includes lamp
watts and
ballast losses.
PRODUCT CODE
Abbreviated product description
can also be used for ordering.
INPUT
VOLTS
Voltage required
from a power
supply for
proper ballast
operation.
THD%
Indicates
percentage of
Total Harmonic
Distortion.
POWER
FACTOR
Watts to volt
amps ratio,
which measures
efciency of a
ballast’s power
usage.
LINE
CURRENT
The current that
results when the
line voltage is
applied to a load. MIN. START TEMP.
References minimum ambient
temperature that the ballast will
reliably start a lamp.
CASE
DIMENSIONS
Species ballast
overall length,
mounting length,
width, and height.
PRODUCT
NUMBER
Use this number when
placing an order.
LAMP TYPE
Indicates the type
of lamp that the
ballast will operate.
CASE
References the ballast’s
case shape.
TOC
ElEctronic FluorEscEnt Ballasts
173
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
F6T5
26 RS 120 50104 E114RS/120 0.23 14 0.53 1.00 <150 0°F 2-7 K 5.90” 5.60” 0.91” 0.76”
F8T5
28 RS 120 50104 E114RS/120 0.25 16 0.53 0.95 <150 0°F 2-7 K 5.90” 5.60” 0.91” 0.76”
F13T5
113 RS 120 50104 E114RS/120 0.22 14 0.53 0.95 <130 0°F 1-7 K 5.90” 5.60” 0.91” 0.76”
F14T5
1
14 RS 120 50104 E114RS/120 0.23 15 0.54 0.95 <130 0°F 1-7 K 5.90” 5.60” 0.91” 0.76”
14 PS 120 52112 EP228PS/MV/MC 0.14 17 0.98 1.07 <10 0°F 1-24 F 9.50” 8.90” 1.30” 1.00”
14 PS 277 52112 EP228PS/MV/MC 0.07 17 0.98 1.07 <10 0°F 1-24 F 9.50” 8.90” 1.30” 1.00”
214 PS 120 52112 EP228PS/MV/MC 0.28 33 0.98 1.04 <10 0°F 2-9 F 9.50” 8.90” 1.30” 1.00”
14 PS 277 52112 EP228PS/MV/MC 0.13 33 0.98 1.04 <10 0°F 2-9 F 9.50” 8.90” 1.30” 1.00”
F21T5
1
21 RS 120 50104 E114RS/120 0.30 21 0.57 0.80 <150 0°F 1-7 K 5.90” 5.60” 0.91” 0.76”
21 PS 120 52112 EP228PS/MV/MC 0.22 25 0.98 1.06 <10 0°F 1-24 F 9.50” 8.90” 1.30” 1.00”
21 PS 277 52112 EP228PS/MV/MC 0.10 25 0.98 1.06 <10 0°F 1-24 F 9.50” 8.90” 1.30” 1.00”
221 PS 120 52112 EP228PS/MV/MC 0.39 49 0.98 1.02 <10 0°F 2-9 F 9.50” 8.90” 1.30” 1.00”
21 PS 277 52112 EP228PS/MV/MC 0.17 49 0.98 1.02 <10 0°F 2-9 F 9.50” 8.90” 1.30” 1.10”
F24T5/HO
1
24 PS 120 50142 EP239HO/PS/MV 0.24 29 0.98 1.10 <12 0°F 1-10 J 16.90” 16.00” 1.20” 1.00”
24 PS 277 50142 EP239HO/PS/MV 0.12 29 0.98 1.12 <12 0°F 1-10 J 16.90” 16.00” 1.20” 1.00”
224 PS 120 50142 EP239HO/PS/MV 0.44 52 0.98 1.00 <12 0°F 2-8 J 16.90” 16.00” 1.20” 1.00”
24 PS 277 50142 EP239HO/PS/MV 0.20 52 0.98 1.00 <12 0°F 2-8 J 16.90” 16.00” 1.20” 1.00”
F28T5
128 PS 120 52112 EP228PS/MV/MC 0.29 31 0.98 1.05 <10 0°F 1-24 F 9.50” 8.90” 1.30” 1.00”
28 PS 277 52112 EP228PS/MV/MC 0.12 31 0.98 1.05 <10 0°F 1-24 F 9.50” 8.90” 1.30” 1.00”
228 PS 120 52112 EP228PS/MV/MC 0.53 62 0.98 1.00 <10 0°F 2-9 F 9.50” 8.90” 1.30” 1.00”
28 PS 277 52112 EP228PS/MV/MC 0.23 61 0.98 1.00 <10 0°F 2-9 F 9.50” 8.90” 1.30” 1.10”
F35T5
135 PS 120 52112 EP228PS/MV/MC 0.34 40 0.98 1.01 <10 0°F 1-24 F 9.50” 8.90” 1.30” 1.00”
35 PS 277 52112 EP228PS/MV/MC 0.15 40 0.98 1.01 <10 0°F 1-24 F 9.50” 8.90” 1.30” 1.00”
F39T5/HO
1
39 PS 120 50142 EP239HO/PS/MV 0.40 48 0.98 1.15 <12 0°F 1-10 J 16.90” 16.00” 1.20” 1.00”
39 PS 277 50142 EP239HO/PS/MV 0.18 48 0.98 1.15 <12 0°F 1-10 J 16.90” 16.00” 1.20” 1.00”
239 PS 120 50142 EP239HO/PS/MV 0.78 94 0.98 1.12 <10 0°F 2-8 J 16.90” 16.00” 1.20” 1.00”
39 PS 277 50142 EP239HO/PS/MV 0.34 94 0.98 1.12 <10 0°F 2-8 J 16.90” 16.00” 1.20” 1.00”
T5
Case diagrams and wiring diagrams can be found on pages 175-177.
TOC
ElEctronic FluorEscEnt Ballasts
174
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T5
T5
F49T5/HO
1
49 PS 120 50144 EP254HO/PS/MV 0.50 59 0.99 1.00 <10 0°F 1-10 J 16.90” 16.00” 1.20” 1.00”
49 PS 277 50144 EP254HO/PS/MV 0.22 57 0.92 1.00 <10 0°F 1-10 J 16.90” 16.00” 1.20” 1.00”
49 PS 120 52114 EP254HO/PS/MV/MC 0.44 53 0.99 0.90 <10 0°F 1-24 F 9.50” 8.90” 1.30” 1.00”
49 PS 277 52114 EP254HO/PS/MV/MC 0.21 58 0.90 1.04 <10 0°F 1-24 F 9.50” 8.90” 1.30” 1.00”
2
49 PS 120 50144 EP254HO/PS/MV 0.94 112 0.99 0.96 <10 0°F 2-8 J 16.90” 16.00” 1.20” 1.00”
49 PS 277 50144 EP254HO/PS/MV 0.41 111 0.98 0.96 <10 0°F 2-8 J 16.90” 16.00” 1.20” 1.00”
49 PS 120 52114 EP254HO/PS/MV/MC 0.88 106 0.98 0.99 <10 0°F 2-9 F 9.50” 8.90” 1.30” 1.00”
49 PS 277 52114 EP254HO/PS/MV/MC 0.38 105 0.97 0.98 <10 0°F 2-9 F 9.50” 8.90” 1.30” 1.00”
49 PS 120 50186 EP454HO/PS/MV 0.88 106 0.98 0.97 <10 -20°F 2-22 J 16.90” 16.30” 1.80” 1.20”
49 PS 277 50186 EP454HO/PS/MV 0.39 104 0.96 0.97 <10 -20°F 2-22 J 16.90” 16.30” 1.80” 1.20”
349 PS 120 50186 EP454HO/PS/MV 1.34 162 0.98 0.97 <10 -20°F 3-10 J 16.90” 16.30” 1.80” 1.20”
49 PS 277 50186 EP454HO/PS/MV 0.61 159 0.93 0.97 <10 -20°F 3-10 J 16.90” 16.30” 1.80” 1.20”
449 PS 120 50186 EP454HO/PS/MV 1.78 214 0.98 0.97 <10 -20°F 4-7 J 16.90” 16.30” 1.80” 1.20”
49 PS 277 50186 EP454HO/PS/MV 0.78 209 0.96 0.97 <10 -20°F 4-7 J 16.90” 16.30” 1.80” 1.20”
F54T5/HO
1
54 RS 120 50140 E154HO/RS/120 0.75 51 0.50 0.95 <140 0°F 1-7 G 9.10” 8.75” 0.95” 0.95”
54 PS 120 50144 EP254HO/PS/MV 0.51 61 0.98 1.02 <10 0°F 1-10 J 16.90” 16.00” 1.20” 1.00”
54 PS 277 50144 EP254HO/PS/MV 0.23 61 0.98 1.02 <10 0°F 1-10 J 16.90” 16.00” 1.20” 1.00”
54 PS 120 52114 EP254HO/PS/MV/MC 0.52 62 0.98 1.03 <10 0°F 1-24 F 9.50” 8.90” 1.30” 1.00”
54 PS 277 52114 EP254HO/PS/MV/MC 0.23 62 0.90 1.03 <20 0°F 1-24 F 9.50” 8.90” 1.30” 1.00”
2
54 PS 120 52114 EP254HO/PS/MV/MC 1.00 120 0.98 1.00 <10 0°F 2-9 F 9.50” 8.90” 1.30” 1.00”
54 PS 277 52114 EP254HO/PS/MV/MC 0.43 117 0.97 1.00 <10 0°F 2-9 F 9.50” 8.90” 1.30” 1.00”
54 PS 120 50144 EP254HO/PS/MV 0.98 117 0.98 1.00 <10 0°F 2-8 J 16.90” 16.00” 1.20” 1.00”
54 PS 277 50144 EP254HO/PS/MV 0.42 117 0.98 1.00 <10 0°F 2-8 J 16.90” 16.00” 1.20” 1.00”
54 PS 120 50186 EP454HO/PS/MV 1.00 120 0.98 1.00 <10 -20°F 2-22 J 16.75” 16.30” 1.80” 1.20”
54 PS 277 50186 EP454HO/PS/MV 0.43 117 0.98 1.00 <10 -20°F 2-22 J 16.75” 16.30” 1.80” 1.20”
354 PS 120 50186 EP454HO/PS/MV 1.50 176 0.98 1.03 <10 -20°F 3-10 J 16.75” 16.30” 1.80” 1.20”
54 PS 277 50186 EP454HO/PS/MV 0.65 173 0.92 1.03 <10 -20°F 3-10 J 16.75” 16.30” 1.80” 1.20”
454 PS 120 50186 EP454HO/PS/MV 2.00 231 0.98 1.00 <10 -20°F 4-7 J 16.75” 16.30” 1.80” 1.20”
54 PS 277 50186 EP454HO/PS/MV 0.86 228 0.98 1.00 <10 -20°F 4-7 J 16.75” 16.30” 1.80” 1.20”
Case diagrams and wiring diagrams can be found on pages 175-177.
TOC
ELECTRONIC FLUORESCENT BALLASTS
175
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
H
W
M
L
M
K
H
W
M
L
G
L
M
H
W
F
H
W
M
L
J
T5
Case Diagrams
TOC
ELECTRONIC FLUORESCENT BALLASTS
176 Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T5
Wiring Diagrams
1-10
BLACK
WHITE
GREEN
RED
BLUE
YELLOW
LAMP
RED
BLUE
YELLOW
BALLAST
BALLAST
BLUE
BLUE
BLACK
WHITE
LINE
RED
RED
LAMP
1-7
LAMP
BALLAST
1-24
BLACK
WHITE
GREEN
BALLAST
BLUE
YEL.
RED
BLUE
YEL.
RED
LAMP 2
LAMP 1
2-8
LAMP 2
LAMP 1
BLUE
BLUE
BLACK
WHITE
LINE
RED
RED
BALLAST
2-7
TOC
ELECTRONIC FLUORESCENT BALLASTS
177
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T5
Wiring Diagrams
LAMP 1
LAMP 2
BALLAST
2-9
4-7
Neutral
or
Any Hot
SW Lamps
Closed 4 Lamps On
Open 2 Lamps On
LAMP 3
LAMP 2
LAMP 1
BALLAST
3-10
Neutral
or
Any Hot
SW Lamps
Closed 3 Lamps On
Open 2 Lamps On
2-22
SW Lamps
Closed 2 Lamps On
Open
Neutral
or
Any Hot
TOC
ElEctronic FluorEscEnt Ballasts
178
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
FC22T5
1
22 PS 120 50142 EP239HO/PS/MV 0.27 33 0.98 1.12 <15 0°F 1-13 J 16.90” 16.00” 1.20” 1.00”
22 PS 277 50142 EP239HO/PS/MV 0.12 33 0.95 1.12 <15 0°F 1-13 J 16.90” 16.00” 1.20” 1.00”
22 PS 120 52108 EP2CF42PS/MV/DC/K 0.27 31 0.93 1.20 <15 0°F 1-13 L 5.00” 4.63” 3.00” 1.38”
22 PS 277 52108 EP2CF42PS/MV/DC/K 0.13 31 0.93 1.20 <15 0°F 1-13 L 5.00” 4.63” 3.00” 1.38”
2
22 PS 120 50142 EP239HO/PS/MV 0.52 63 0.99 1.10 <10 0°F 2-13 J 16.90” 16.00” 1.20” 1.00”
22 PS 277 50142 EP239HO/PS/MV 0.23 63 0.99 1.10 <10 0°F 2-13 J 16.90” 16.00” 1.20” 1.00”
22 PS 120 52108 EP2CF42PS/MV/DC/K 0.49 59 0.97 1.10 <12 0°F 2-13 L 5.00” 4.63” 3.00” 1.38”
22 PS 277 52108 EP2CF42PS/MV/DC/K 0.22 52 0.97 1.10 <12 0°F 2-13 L 5.00” 4.63” 3.00” 1.38”
FC22T5 + FC40T5
2
22+40 PS 120 50142 *EP239HO/PS/MV 0.58 68 0.98 1.00 <12 0°F 2-13 J 16.90” 16.00” 1.20” 1.00”
22+40 PS 277 50142 *EP239HO/PS/MV 0.25 68 0.98 1.00 <12 0°F 2-13 J 16.90” 16.00” 1.20” 1.00”
22+40 PS 120 52108 *EP2CF42PS/MV/DC/K 0.55 67 0.99 0.90 <10 0°F 2-13 L 5.00” 4.63” 3.00” 1.38”
22+40 PS 277 52108 *EP2CF42PS/MV/DC/K 0.25 67 0.98 0.90 <10 0°F 2-13 L 5.00” 4.63” 3.00” 1.38”
FC40T5
1
40 PS 120 50142 EP239HO/PS/MV 0.40 48 0.98 0.92 <12 0°F 1-13 J 16.90” 16.00” 1.20” 1.00”
40 PS 277 50142 EP239HO/PS/MV 0.18 48 0.98 0.92 <12 0°F 1-13 J 16.90” 16.00” 1.20” 1.00”
40 PS 120 52106 EP2CF26PS/MV/DC/K 0.36 42 0.99 1.00 <12 0°F 1-13 L 5.00” 4.63” 2.40” 1.00”
40 PS 277 52106 EP2CF26PS/MV/DC/K 0.16 42 0.99 1.00 <12 0°F 1-13 L 5.00” 4.63” 2.40” 1.00”
40 PS 120 52108 EP2CF42PS/MV/DC/K 0.37 45 0.99 1.00 <15 0°F 1-13 L 5.00” 4.63” 3.00” 1.38”
40 PS 277 52108 EP2CF42PS/MV/DC/K 0.17 45 0.99 1.00 <15 0°F 1-13 L 5.00” 4.63” 3.00” 1.38”
2
40 PS 120 50142 EP239HO/PS/MV 0.77 92 0.98 0.90 <12 0°F 2-13 J 16.90” 16.00” 1.20” 1.00”
40 PS 277 50142 EP239HO/PS/MV 0.33 92 0.98 0.90 <12 0°F 2-13 J 16.90” 16.00” 1.20” 1.00”
40 PS 120 52108 EP2CF42PS/MV/DC/K 0.69 82 0.99 0.95 <12 0°F 2-13 L 5.00” 4.63” 3.00” 1.38”
40 PS 277 52108 EP2CF42PS/MV/DC/K 0.30 82 0.99 0.95 <12 0°F 2-13 L 5.00” 4.63” 3.00” 1.38”
FC55T5/HO
155 PS 120 50144 EP254HO/PS/MV 0.46 55 0.96 0.81 <15 0°F 1-13 J 16.90” 16.00” 1.20” 1.00”
55 PS 277 50144 EP254HO/PS/MV 0.21 55 0.96 0.81 <15 0°F 1-13 J 16.90” 16.00” 1.20” 1.00”
255 PS 120 50144 EP254HO/PS/MV 0.89 106 0.98 0.85 <10 0°F 2-13 J 16.90” 16.00” 1.20” 1.00”
55 PS 277 50144 EP254HO/PS/MV 0.38 103 0.98 0.85 <10 0°F 2-13 J 16.90” 16.00” 1.20” 1.00”
T5 Circline
*Ballast operates two different lamps together.
Case diagrams and wiring diagrams can be found on page 179.
TOC
ELECTRONIC FLUORESCENT BALLASTS
179
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T5 Circline
BLACK
WHITE
GREEN
BALLAST
BLUE
BLUE
RED
RED
YEL
YEL
1-13
BLACK
WHITE
GREEN
BALLAST
BLUE
BLUE
RED
RED
YEL
YEL
2-13
H
WL
M
L
H
W
M
L
J
Case Diagrams
Wiring Diagrams
TOC
ElEctronic FluorEscEnt Ballasts
180
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
F14T8
114 RS 120 50108 VE120RS/120 0.24 15.5 0.54 1.00 <150 0°F 1-18 F 6.46” 6.00” 1.37” 1.00”
214 RS 120 50110 E220RS/120 0.44 29 0.54 0.88 <130 0°F 2-12 F 6.46” 6.00” 1.37” 1.00”
F15T8
115 RS 120 50108 VE120RS/120 0.25 16 0.55 1.00 <140 0°F 1-18 F 6.46” 6.00” 1.37” 1.00”
215 RS 120 50110 E220RS/120 0.49 32 0.56 1.00 <130 0°F 2-12 F 6.46” 6.00” 1.37” 1.00”
F17T8, FB16
1
17 RS 120 50108 VE120RS/120 0.27 18.5 0.56 1.00 <140 0°F 1-18 F 6.46” 6.00” 1.37” 1.00”
17 IS 120 50118 E232IS/120/R/MC 0.35 20 0.45 1.05 <150 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
17 IS 120 50112 EP132IS/MV/MC 0.15 17 0.99 0.91 <10 0°F 1-3 F 9.50” 8.90” 1.30” 1.00”
17 IS 277 50112 EP132IS/MV/MC 0.07 17 0.95 0.91 <15 0°F 1-3 F 9.50” 8.90” 1.30” 1.00”
17 IS 120 50115 EP232IS/H/MV/HE 0.22 25 0.95 1.42 <10 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50115 EP232IS/H/MV/HE 0.11 25 0.95 1.42 <15 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
17 IS 120 50119 EP232IS/L/MV/HE 0.14 17 0.98 0.96 <10 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50119 EP232IS/L/MV/HE 0.08 16 0.80 0.96 <20 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
17 IS 120 50123 EP232IS/MV/HE 0.16 21 0.98 1.10 <10 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50123 EP232IS/MV/HE 0.09 21 0.95 1.10 <15 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
17 IS 120 50116 EP232IS/MV/MC 0.18 22 0.98 1.10 <10 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50116 EP232IS/MV/MC 0.08 21 0.95 1.10 <15 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
17 PS 120 50180 EP232PS/MV/HE 0.20 23 0.98 1.03 <10 0°F 1-11 F 9.50” 8.90” 1.38” 1.18”
17 PS 277 50180 EP232PS/MV/HE 0.09 24 0.93 1.03 <12 0°F 1-11 F 9.50” 8.90” 1.38” 1.18”
17 PS 120 50178 EP232PS/L/MV/HE 0.28 33 0.99 0.86 <10 0°F 1-11 F 9.50” 8.90” 1.38” 1.18”
17 PS 277 50178 EP232PS/L/MV/HE 0.12 33 0.98 0.86 <10 0°F 1-11 F 9.50” 8.90” 1.38” 1.18”
2
17 RS 120 50110 E220RS/120 0.54 36 0.58 1.00 <130 0°F 2-12 F 6.46” 6.00” 1.37” 1.00”
17 IS 120 50118 E232IS/120/R/MC 0.52 31 0.52 0.86 <160 0°F 2-17 F 9.50” 8.90” 1.30” 1.00”
17 IS 120 50176 EP232IS/120/MC 0.31 33 0.90 0.86 <35 0°F 2-17 F 9.50” 8.90” 1.30” 1.00”
17 IS 120 50115 EP232IS/H/MV/HE 0.33 39 0.98 1.23 <10 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50115 EP232IS/H/MV/HE 0.15 39 0.96 1.23 <10 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
17 IS 120 50119 EP232IS/L/MV/HE 0.21 25 0.98 0.80 <10 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50119 EP232IS/L/MV/HE 0.09 23 0.85 0.80 <20 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
17 IS 120 50123 EP232IS/MV/HE 0.25 28 0.98 0.91 <10 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50123 EP232IS/MV/HE 0.11 28 0.97 0.91 <15 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
17 IS 120 50116 EP232IS/MV/MC 0.26 31 0.98 0.91 <10 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50116 EP232IS/MV/MC 0.12 31 0.97 0.91 <15 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
17 PS 120 50180 EP232PS/MV/HE 0.30 34 0.98 0.90 <10 0°F 2-24 F 9.50” 8.90” 1.38” 1.18”
17 PS 277 50180 EP232PS/MV/HE 0.13 35 0.96 0.90 <10 0°F 2-24 F 9.50” 8.90” 1.38” 1.18”
17 PS 120 50178 EP232PS/L/MV/HE 0.44 52 0.99 0.77 <10 0°F 2-24 F 9.50” 8.90” 1.38” 1.18”
17 PS 277 50178 EP232PS/L/MV/HE 0.19 52 0.98 0.77 <10 0°F 2-24 F 9.50” 8.90” 1.38” 1.18”
V Item will be discontinued when inventory is depleted.
T8
Case diagrams and wiring diagrams can be found on pages 190-192.
TOC
ElEctronic FluorEscEnt Ballasts
181
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
F17T8, FB16
continued
3
17 IS 120 50121 EP332IS/H/MV/HE 0.49 58 0.99 1.23 <10 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50121 EP332IS/H/MV/HE 0.22 57 0.96 1.23 <10 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
17 IS 120 50168 EP332IS/L/MV/HE 0.37 43 0.98 0.86 <10 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50168 EP332IS/L/MV/HE 0.16 43 0.95 0.86 <15 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
17 IS 120 50170 EP332IS/MV/HE 0.38 45 0.98 0.92 <10 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50170 EP332IS/MV/HE 0.17 45 0.96 0.92 <15 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
17 IS 120 50122 EP332IS/MV/MC 0.38 45 0.98 0.90 <10 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50122 EP332IS/MV/MC 0.17 45 0.96 0.90 <15 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
17 PS 120 50184 EP432PS/MV/HE 0.45 53 0.98 0.94 <10 0°F 3-8 F 9.50” 8.90” 1.65” 1.18”
17 PS 277 50184 EP432PS/MV/HE 0.21 53 0.95 0.94 <15 0°F 3-8 F 9.50” 8.90” 1.65” 1.18”
17 PS 120 50182 EP432PS/L/MV/HE 0.40 48 0.99 0.81 <10 0°F 3-8 F 9.50” 8.90” 1.65” 1.18”
17 PS 277 50182 EP432PS/L/MV/HE 0.18 49 0.96 0.82 <12 0°F 3-8 F 9.50” 8.90” 1.65” 1.18”
4
17 IS 120 50158 E432IS/120/R/MC 0.97 67 0.50 0.95 <175 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
17 IS 120 50124 EP432IS/120/MC 0.51 61 0.98 0.96 <20 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
17 IS 120 50172 EP432IS/L/MV/HE 0.46 54 0.98 0.79 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.18”
17 IS 277 50172 EP432IS/L/MV/HE 0.19 52 0.98 0.79 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.18”
17 IS 120 50174 EP432IS/MV/HE 0.49 59 0.98 0.93 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50174 EP432IS/MV/HE 0.22 58 0.98 0.93 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
17 IS 120 50126 EP432IS/MV/MC 0.49 59 0.98 0.90 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
17 IS 277 50126 EP432IS/MV/MC 0.22 58 0.98 0.90 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
17 PS 120 50184 EP432PS/MV/HE 0.52 63 0.98 0.87 <10 0°F 4-5 F 9.50” 8.90” 1.65” 1.18”
17 PS 277 50184 EP432PS/MV/HE 0.24 63 0.97 0.89 <12 0°F 4-5 F 9.50” 8.90” 1.65” 1.18”
17 PS 120 50182 EP432PS/L/MV/HE 0.46 55 0.99 0.73 <10 0°F 4-5 F 9.50” 8.90” 1.65” 1.18”
17 PS 277 50182 EP432PS/L/MV/HE 0.21 56 0.97 0.74 <12 0°F 4-5 F 9.50” 8.90” 1.65” 1.18”
F18T8 24”
118 RS 120 50108 E120RS/120 0.26 17.5 0.55 0.95 <140 0°F 1-18 F 6.46” 6.00” 1.37” 1.00”
218 RS 120 50110 E220RS/120 0.50 34 0.57 0.92 <150 0°F 2-12 F 6.46” 6.00” 1.37” 1.00”
F20T8
120 RS 120 50108 E120RS/120 0.26 18 0.56 0.90 <130 0°F 1-18 F 6.46” 6.00” 1.37” 1.00”
T8
Case diagrams and wiring diagrams can be found on pages 190-192.
TOC
ElEctronic FluorEscEnt Ballasts
182
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
F25T8/ES (F32T8 25W)
1
25 IS 120 50119
EP232IS/L/MV/HE
0.21 25 0.98 0.93 <10
60°F
1-3 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50119
EP232IS/L/MV/HE
0.10 23 0.80 0.93 <20
60°F
1-3 F
9.50” 8.90” 1.30” 1.10”
25 IS 120 50123
EP232IS/MV/HE
0.24 29 0.98 1.08 <10
60°F
1-3 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50123
EP232IS/MV/HE
0.11 29 0.97 1.08 <15
60°F
1-3 F
9.50” 8.90” 1.30” 1.10”
25 PS 120 50180
EP232PS/MV/HE
0.27 33 0.99 1.05 <10
60°F
1-11 F
9.50” 8.90” 1.38” 1.18”
25 PS 277 50180
EP232PS/MV/HE
0.12 33 0.95 1.05 <12
60°F
1-11 F
9.50” 8.90” 1.38” 1.18”
25
PS 120 50178
EP232PS/L/MV/HE
0.24 28 0.99 0.92 <10
60°F
1-11 F
9.50” 8.90” 1.38” 1.18”
25 PS 277 50178
EP232PS/L/MV/HE
0.11 29 0.97 0.92 <12
60°F
1-11 F
9.50” 8.90” 1.38” 1.18”
2
25 IS 120 50119
EP232IS/L/MV/HE
0.31 37 0.98 0.79 <10
60°F
2-17 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50119
EP232IS/L/MV/HE
0.13 35 0.95 0.79 <15
60°F
2-17 F
9.50” 8.90” 1.30” 1.10”
25 IS 120 50123
EP232IS/MV/HE
0.39 46 0.98 0.89 <10
60°F
2-17 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50123
EP232IS/MV/HE
0.17 45 0.97 0.89 <15
60°F
2-17 F
9.50” 8.90” 1.30” 1.10”
25 PS 120 50178 EP232PS/L/MV/HE 0.37 44 0.99 0.79 <10 60°F 2-24 F 9.50” 8.90” 1.38” 1.18”
25 PS 277 50178 EP232PS/L/MV/HE 0.16 44 0.98 0.79 <10 60°F 2-24 F 9.50” 8.90” 1.38” 1.18”
25 PS 120 50180
EP232PS/MV/HE
0.42 50 0.99 0.92 <10
60°F
2-24 F
9.50” 8.90” 1.38” 1.18”
25 PS 277 50180
EP232PS/MV/HE
0.19 50 0.97 0.92 <10
60°F
2-24 F
9.50” 8.90” 1.38” 1.18”
25 IS 120 50168
EP332IS/L/MV/HE
0.41 48 0.98 0.95 <10
60°F
2-11 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50168
EP332IS/L/MV/HE
0.18 47 0.95 0.92 <15
60°F
2-11 F
9.50” 8.90” 1.30” 1.10”
25 IS 120 50170
EP332IS/MV/HE
0.43 51 0.98 1.00 <10
60°F
2-11 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50170
EP332IS/MV/HE
0.19 51 0.97 1.00 <15
60°F
2-11 F
9.50” 8.90” 1.30” 1.10”
3
25 IS 120 50168 EP332IS/L/MV/HE 0.53 63 0.98 0.85 <10 60°F 3-7 F 9.50” 8.90” 1.30” 1.10”
25 IS 277 50168 EP332IS/L/MV/HE 0.23 61 0.95 0.85 <15 60°F 3-7 F 9.50” 8.90” 1.30” 1.10”
25 IS 120 50170 EP332IS/MV/HE 0.56 68 0.98 0.90 <10 60°F 3-7 F 9.50” 8.90” 1.30” 1.10”
25 IS 277 50170 EP332IS/MV/HE 0.25 68 0.97 0.90 <15 60°F 3-7 F 9.50” 8.90” 1.30” 1.10”
25 IS 120 50172 EP432IS/L/MV/HE 0.57 68 0.98 0.84 <10 60°F 3-9 F 9.50” 8.90” 1.30” 1.18”
25 IS 277 50172 EP432IS/L/MV/HE 0.25 68 0.95 0.84 <15 60°F 3-9 F 9.50” 8.90” 1.30” 1.18”
25 IS 120 50174 EP432IS/MV/HE 0.62 74 0.98 0.96 <10 60°F 3-9 F 9.50” 8.90” 1.30” 1.18”
25 IS 277 50174 EP432IS/MV/HE 0.27 73 0.98 0.96 <10 60°F 3-9 F 9.50” 8.90” 1.30” 1.18”
25 PS 120 50184 EP432PS/MV/HE 0.64 76 0.99 0.94 <10 60°F 3-8 F 9.50” 8.90” 1.65” 1.18”
25 PS 277 50184 EP432PS/MV/HE 0.28 76 0.98 0.94 <10 60°F 3-8 F 9.50” 8.90” 1.65” 1.18”
25 PS 120 50182 EP432PS/L/MV/HE 0.56 67 0.99 0.81 <10 60°F 3-8 F 9.50” 8.90” 1.65” 1.18”
25 PS 277 50182 EP432PS/L/MV/HE 0.25 68 0.98 0.82 <10 60°F 3-8 F 9.50” 8.90” 1.65” 1.18”
T8
Case diagrams and wiring diagrams can be found on pages 190-192.
TOC
ElEctronic FluorEscEnt Ballasts
183
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
F25T8/ES (F32T8 25W) continued
4
25 IS 120 50172 EP432IS/L/MV/HE 0.69 82 0.98 0.78 <10 60°F 4-6 F 9.50” 8.90” 1.30” 1.18”
25 IS 277 50172 EP432IS/L/MV/HE 0.30 81 0.98 0.78 <10 60°F 4-6 F 9.50” 8.90” 1.30” 1.18”
25 IS 120 50174 EP432IS/MV/HE 0.74 88 0.98 0.88 <10 60°F 4-6 F 9.50” 8.90” 1.30” 1.18”
25 IS 277 50174 EP432IS/MV/HE 0.32 88 0.98 0.88 <10 60°F 4-6 F 9.50” 8.90” 1.30” 1.18”
25 PS 120 50184 EP432PS/MV/HE 0.77 93 0.99 0.89 <10 60°F 4-5 F 9.50” 8.90” 1.65” 1.18”
25 PS 277 50184 EP432PS/MV/HE 0.34 93 0.98 0.89 <10 60°F 4-5 F 9.50” 8.90” 1.65” 1.18”
25 PS 120 50182 EP432PS/L/MV/HE 0.67 80 0.99 0.75 <10 60°F 4-5 F 9.50” 8.90” 1.65” 1.18”
25 PS 277 50182 EP432PS/L/MV/HE 0.30 81 0.98 0.76 <10 60°F 4-5 F 9.50” 8.90” 1.65” 1.18”
F25T8, FB24
1
25 IS 120 50118
E232IS/120/R/MC
0.46 27 0.50 1.01 <170 0°F 1-3 F
9.50” 8.90” 1.30” 1.10”
25 IS 120 50112
EP132IS/MV/MC
0.21 24 0.99 0.92 <10 0°F 1-23 F
9.50” 8.90” 1.30” 1.00”
25 IS 277 50112
EP132IS/MV/MC
0.10 24 0.97 0.92 <10 0°F 1-23 F
9.50” 8.90” 1.30” 1.00”
25 IS 120 50115
EP232IS/H/MV/HE
0.28 33 0.98 1.40 <10 0°F 1-3 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50115
EP232IS/H/MV/HE
0.13 33 0.96 1.40 <15 0°F 1-3 F
9.50” 8.90” 1.30” 1.10”
25 IS 120 50119
EP232IS/L/MV/HE
0.20 24 0.98 0.95 <10 0°F 1-3 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50119
EP232IS/L/MV/HE
0.09 22 0.80 0.95 <20 0°F 1-3 F
9.50” 8.90” 1.30” 1.10”
25 IS 120 50123
EP232IS/MV/HE
0.23 26 0.98 1.08 <10 0°F 1-3 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50123
EP232IS/MV/HE
0.10 26 0.96 1.08 <15 0°F 1-3 F
9.50” 8.90” 1.30” 1.10”
25 IS 120 50116
EP232IS/MV/MC
0.24 29 0.98 1.08 <10 0°F 1-3 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50116
EP232IS/MV/MC
0.11 28 0.96 1.08 <15 0°F 1-3 F
9.50” 8.90” 1.30” 1.10”
25 PS 120 50180
EP232PS/MV/HE
0.26 31 0.98 1.01 <10 0°F 1-11 F
9.50” 8.90” 1.38” 1.18”
25 PS 277 50180
EP232PS/MV/HE
0.12 32 0.95 1.01 <12 0°F 1-11 F
9.50” 8.90” 1.38” 1.18”
25 PS 120 50178
EP232PS/L/MV/HE
0.23 27 0.99 0.88 <10 0°F 1-11 F
9.50” 8.90” 1.38” 1.18”
25 PS 277 50178
EP232PS/L/MV/HE
0.10 28 0.97 0.88 <12 0°F 1-11 F
9.50” 8.90” 1.38” 1.18”
2
25 IS 120 50118
E232IS/120/R/MC
0.65 43 0.54 0.84 <140 0°F 2-17 F
9.50” 8.90” 1.30” 1.10”
25 IS 120 50176
EP232IS/120/MC
0.41 47 0.96 0.85 <30 0°F 2-17 F
9.50” 8.90” 1.30” 1.00”
25 IS 120 50115
EP232IS/H/MV/ME
0.45 54 0.98 1.20 <10 0°F 2-17 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50115
EP232IS/H/MV/ME
0.20 54 0.97 1.20 <15 0°F 2-17 F
9.50” 8.90” 1.30” 1.10”
25 IS 120 50119
EP232IS/L/MV/HE
0.31 37 0.98 0.79 <10 0°F 2-17 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50119
EP232IS/L/MV/HE
0.13 35 0.95 0.79 <15 0°F 2-17 F
9.50” 8.90” 1.30” 1.10”
25 IS 120 50123
EP232IS/MV/HE
0.36 42 0.98 0.89 <10 0°F 2-17 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50123
EP232IS/MV/HE
0.16 41 0.98 0.89 <15 0°F 2-17 F
9.50” 8.90” 1.30” 1.10”
25 IS 120 50116
EP232IS/MV/MC
0.38 46 0.98 0.89 <10 0°F 2-17 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50116
EP232IS/MV/MC
0.17 46 0.97 0.89 <15 0°F 2-17 F
9.50” 8.90” 1.30” 1.10”
25 PS 120 50180
EP232PS/MV/HE
0.40 47 0.99 0.83 <10 0°F 2-24 F
9.50” 8.90” 1.38” 1.18”
T8
Case diagrams and wiring diagrams can be found on pages 190-192.
TOC
ElEctronic FluorEscEnt Ballasts
184
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
F25T8, FB24
continued
2
25 PS 277 50180
EP232PS/MV/HE
0.18 47 0.95 0.88 <10 0°F 2-24 F
9.50” 8.90” 1.38” 1.18”
25 PS 120 50178
EP232PS/L/MV/HE
0.35 41 0.99 0.74 <10 0°F 2-24 F
9.50” 8.90” 1.38” 1.18”
25 PS 277 50178
EP232PS/L/MV/HE
0.15 41 0.98 0.74 <10 0°F 2-24 F
9.50” 8.90” 1.38” 1.18”
25 IS 120 50121
EP332IS/H/MV/HE
0.55 65 0.98 1.28 <10 0°F 2-11 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50121
EP332IS/H/MV/HE
0.25 65 0.97 1.28 <15 0°F 2-11 F
9.50” 8.90” 1.30” 1.10”
25 IS 120 50170
EP332IS/MV/HE
0.42 50 0.98 1.00 <10 0°F 2-11 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50170
EP332IS/MV/HE
0.18 50 0.96 1.00 <15 0°F 2-11 F
9.50” 8.90” 1.30” 1.10”
25 IS 120 50122
EP332IS/MV/MC
0.42 50 0.98 0.98 <10 0°F 2-11 F
9.50” 8.90” 1.30” 1.10”
25 IS 277 50122
EP332IS/MV/MC
0.18 50 0.96 0.98 <15 0°F 2-11 F
9.50” 8.90” 1.30” 1.10”
3
25 IS 120 50121 EP332IS/H/MV/HE 0.39 81 0.98 1.20 <10
0°F
3-7 F 9.50” 8.90” 1.30” 1.10”
25 IS 277 50121 EP332IS/H/MV/HE 0.30 81 0.98 1.20 <10
0°F
3-7 F 9.50” 8.90” 1.30” 1.10”
25 IS 120 50168 EP332IS/L/MV/HE 0.51 60 0.98 0.82 <10
0°F
3-7 F 9.50” 8.90” 1.30” 1.10”
25 IS 277 50168 EP332IS/L/MV/HE 0.22 58 0.95 0.82 <15
0°F
3-7 F 9.50” 8.90” 1.30” 1.10”
25 IS 120 50170 EP332IS/MV/HE 0.56 68 0.98 0.90 <10
0°F
3-7 F 9.50” 8.90” 1.30” 1.10”
25 IS 277 50170 EP332IS/MV/HE 0.24 68 0.97 0.90 <15
0°F
3-7 F 9.50” 8.90” 1.30” 1.10”
25 IS 120 50122 EP332IS/MV/MC 0.56 68 0.98 0.88 <10
0°F
3-7 F 9.50” 8.90” 1.30” 1.10”
25 IS 277 50122 EP332IS/MV/MC 0.24 66 0.97 0.88 <15
0°F
3-7 F 9.50” 8.90” 1.30” 1.10”
25 IS 120 50158 E432IS/120/R/MC 1.12 77 0.50 1.00 <175
0°F
3-9 F 9.50” 8.90” 1.30” 1.10”
25 IS 120 50124 EP432IS/120/MC 0.62 74 0.98 1.04 <20
0°F
3-9 F 9.50” 8.90” 1.30” 1.10”
25 IS 120 50172 EP432IS/L/MV/HE 0.53 62 0.98 0.84 <10
0°F
3-9 F 9.50” 8.90” 1.30” 1.10”
25 IS 277 50172 EP432IS/L/MV/HE 0.23 61 0.95 0.84 <15
0°F
3-9 F 9.50” 8.90” 1.30” 1.10”
25 PS 120 50184 EP432PS/MV/HE 0.62 74 0.98 0.90 <10
0°F
3-8 F 9.50” 8.90” 1.65” 1.18”
25 PS 277 50184 EP432PS/MV/HE 0.28 74 0.97 0.90 <12
0°F
3-8 F 9.50” 8.90” 1.65” 1.18”
25 PS 120 50182 EP432PS/L/MV/HE 0.55 65 0.99 0.80 <10
0°F
3-8 F 9.50” 8.90” 1.65” 1.18”
25 PS 277 50182 EP432PS/L/MV/HE 0.24 66 0.98 0.80 <10
0°F
3-8 F 9.50” 8.90” 1.65” 1.18”
4
25 IS 120 50158 E432IS/R/120/MC 1.25 86 0.50 0.86 <170 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
25 IS 120 50124 EP432IS/120/MC 0.74 89 0.98 0.94 <20 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
25 IS 120 50172 EP432IS/L/MV/HE 0.64 76 0.98 0.78 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
25 IS 277 50172 EP432IS/L/MV/HE 0.27 74 0.98 0.78 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
25 IS 120 50174 EP432IS/MV/HE 0.73 87 0.98 0.89 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
25 IS 277 50174 EP432IS/MV/HE 0.32 85 0.98 0.89 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
25 IS 120 50126 EP432IS/MV/MC 0.72 87 0.98 0.86 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
25 IS 277 50126 EP432IS/MV/MC 0.32 85 0.98 0.86 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
25 PS 120 50184 EP432PS/MV/HE 0.74 88 0.99 0.84 <10 0°F 4-5 F 9.50” 8.90” 1.65” 1.18”
25 PS 277 50184 EP432PS/MV/HE 0.33 88 0.98 0.85 <10 0°F 4-5 F 9.50” 8.90” 1.65” 1.18”
25 PS 120 50182 EP432PS/L/MV/HE 0.65 77 0.99 0.73 <10 0°F 4-5 F 9.50” 8.90” 1.65” 1.18”
25 PS 277 50182 EP432PS/L/MV/HE 0.29 78 0.98 0.73 <10 0°F 4-5 F 9.50” 8.90” 1.65” 1.18”
T8
Case diagrams and wiring diagrams can be found on pages 190-192.
TOC
ElEctronic FluorEscEnt Ballasts
185
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
F28T8
1
28 IS 120 50115 EP232IS/H/MV/HE 0.33 39 0.98 1.38 <10 60°F 1-3 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50115 EP232IS/H/MV/HE 0.15 39 0.97 1.38 <15 60°F 1-3 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50119 EP232IS/L/MV/HE 0.22 26 0.98 0.93 <10 60°F 1-3 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50119 EP232IS/L/MV/HE 0.10 24 0.85 0.93 <20 60°F 1-3 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50123 EP232IS/MV/HE 0.25 30 0.98 1.08 <10 60°F 1-3 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50123 EP232IS/MV/HE 0.11 29 0.97 1.08 <15 60°F 1-3 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50116 EP232IS/MV/MC 0.26 31 0.98 1.08 <10 60°F 1-3 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50116 EP232IS/MV/MC 0.12 31 0.97 1.08 <10 60°F 1-3 F 9.50” 8.90” 1.30” 1.10”
28 PS 120 50180 EP232PS/MV/HE 0.29 35 0.99 1.06 <10 60°F 1-11 F 9.50” 8.90” 1.38” 1.18”
28 PS 277 50180 EP232PS/MV/HE 0.13 35 0.96 1.06 <10 60°F 1-11 F 9.50” 8.90” 1.38” 1.18”
28 PS 120 50178 EP232PS/L/MV/HE 0.25 30 0.99 0.86 <10 60°F 1-11 F 9.50” 8.90” 1.38” 1.18”
28 PS 277 50178 EP232PS/L/MV/HE 0.11 30 0.97 0.86 <12 60°F 1-11 F 9.50” 8.90” 1.38” 1.18”
2
28 IS 120 50115 EP232IS/H/MV/HE 0.54 64 0.98 1.18 <10 60°F 2-17 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50115 EP232IS/H/MV/HE 0.24 63 0.98 1.18 <15 60°F 2-17 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50119 EP232IS/L/MV/HE 0.35 41 0.98 0.78 <10 60°F 2-17 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50119 EP232IS/L/MV/HE 0.15 41 0.97 0.78 <15 60°F 2-17 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50123 EP232IS/MV/HE 0.41 49 0.98 0.89 <10 60°F 2-17 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50123 EP232IS/MV/HE 0.18 47 0.97 0.89 <15 60°F 2-17 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50116 EP232IS/MV/MC 0.41 49 0.98 0.89 <10 60°F 2-17 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50116 EP232IS/MV/MC 0.18 48 0.97 0.89 <15 60°F 2-17 F 9.50” 8.90” 1.30” 1.10”
28 PS 120 50180 EP232PS/MV/HE 0.45 54 0.99 0.90 <10 60°F 2-24 F 9.50” 8.90” 1.38” 1.18”
28 PS 277 50180 EP232PS/MV/HE 0.20 54 0.98 0.90 <10 60°F 2-24 F 9.50” 8.90” 1.38” 1.18”
28 PS 120 50178 EP232PS/L/MV/HE 0.39 46 0.99 0.75 <10 60°F 2-24 F 9.50” 8.90” 1.38” 1.18”
28 PS 277 50178 EP232PS/L/MV/HE 0.17 47 0.98 0.75 <10 60°F 2-24 F 9.50” 8.90” 1.38” 1.18”
28 IS 120 50121 EP332IS/H/MV/HE 0.59 70 0.98 1.27 <10 60°F 2-11 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50121 EP332IS/H/MVHE 0.26 69 0.97 1.27 <15 60°F 2-11 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50168 EP332IS/L/MV/HE 0.42 49 0.98 0.92 <10 60°F 2-11 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50168 EP332IS/L/MV/HE 0.19 48 0.95 0.92 <15 60°F 2-11 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50170 EP332IS/MV/HE 0.45 54 0.98 0.99 <10 60°F 2-11 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50170 EP332IS/MV/HE 0.20 53 0.97 0.99 <15 60°F 2-11 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50122 EP332IS/MV/MC 0.45 54 0.98 0.97 <10 60°F 2-11 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50122 EP332IS/MV/MC 0.20 53 0.97 0.97 <15 60°F 2-11 F 9.50” 8.90” 1.30” 1.10”
T8
Case diagrams and wiring diagrams can be found on pages 190-192.
TOC
ElEctronic FluorEscEnt Ballasts
186
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
F28T8
continued
3
28 IS 120 50121 EP332IS/H/MV/HE 0.78 93 0.98 1.18 <10 60°F 3-7 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50121 EP332IS/H/MV/HE 0.34 92 0.98 1.18 <10 60°F 3-7 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50168 EP332IS/L/MV/HE 0.55 64 0.98 0.81 <10 60°F 3-7 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50168 EP332IS/L/MV/HE 0.24 63 0.95 0.81 <15 60°F 3-7 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50170 EP332IS/MV/HE 0.60 72 0.98 0.88 <10 60°F 3-7 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50170 EP332IS/MV/HE 0.26 70 0.98 0.88 <15 60°F 3-7 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50122 EP332IS/MV/MC 0.60 72 0.98 0.86 <10 60°F 3-7 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50122 EP332IS/MV/MC 0.26 70 0.98 0.86 <15 60°F 3-7 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50172 EP432IS/L/MV/HE 0.59 70 0.98 0.82 <10 60°F 3-9 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50172 EP432IS/L/MV/HE 0.26 70 0.97 0.82 <10 60°F 3-9 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50174 EP432IS/MV/HE 0.65 77 0.96 0.98 <10 60°F 3-9 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50174 EP432IS/MV/HE 0.29 77 0.96 0.98 <10 60°F 3-9 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50126 EP432IS/MV/MC 0.65 77 0.98 0.92 <10 60°F 3-9 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50126 EP432IS/MV/MC 0.29 77 0.97 0.92 <10 60°F 3-9 F 9.50” 8.90” 1.30” 1.10”
28 PS 120 50184 EP432PS/MV/HE 0.70 83 0.99 0.92 <10 60°F 3-8 F 9.50” 8.90” 1.65” 1.18”
28 PS 277 50184 EP432PS/MV/HE 0.31 83 0.97 0.93 <12 60°F 3-8 F 9.50” 8.90” 1.65” 1.18”
28 PS 120 50182 VEP432PS/L/MV/HE 0.61 72 0.99 0.80 <10 60°F 3-8 F 9.50” 8.90” 1.65” 1.18”
28 PS 277 50182 VEP432PS/L/MV/HE 0.27 73 0.98 0.82 <10 60°F 3-8 F 9.50” 8.90” 1.65” 1.18”
4
28 IS 120 50172 EP432IS/L/MV/HE 0.71 84 0.98 0.77 <10 60°F 4-6 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50172 EP432IS/L/MV/HE 0.31 84 0.98 0.77 <10 60°F 4-6 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50174 EP432IS/MV/HE 0.79 94 0.98 0.88 <10 60°F 4-6 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50174 EP432IS/MV/HE 0.35 94 0.98 0.88 <10 60°F 4-6 F 9.50” 8.90” 1.30” 1.10”
28 IS 120 50126 EP432IS/MV/MC 0.79 94 0.98 0.85 <10 60°F 4-6 F 9.50” 8.90” 1.30” 1.10”
28 IS 277 50126 EP432IS/MV/MC 0.35 94 0.98 0.85 <10 60°F 4-6 F 9.50” 8.90” 1.30” 1.10”
28 PS 120 50184 EP432PS/MV/HE 0.84 100 0.99 0.85 <10 60°F 4-5 F 9.50” 8.90” 1.65” 1.18”
28 PS 277 50184 EP432PS/MV/HE 0.37 100 0.98 0.86 <10 60°F 4-5 F 9.50” 8.90” 1.65” 1.18”
28 PS 120 50182 VEP432PS/L/MV/HE 0.73 87 0.99 0.73 <10 60°F 4-5 F 9.50” 8.90” 1.65” 1.18”
28 PS 277 50182 VEP432PS/L/MV/HE 0.32 88 0.98 0.75 <10 60°F 4-5 F 9.50” 8.90” 1.65” 1.18”
V Item will be discontinued when inventory is depleted.
T8
Case diagrams and wiring diagrams can be found on pages 190-192.
TOC
ElEctronic FluorEscEnt Ballasts
187
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
F32T8, FB32, FB31
1
32 IS 120 50118 E232IS/120/R/MC 0.55 34 0.52 1.03 <155 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50112 EP132IS/MV/MC 0.26 31 0.99 0.88 <10 0°F 1-23 F 9.50” 8.90” 1.30” 1.00”
32 IS 277 50112 EP132IS/MV/MC 0.12 31 0.98 0.88 <10 0°F 1-23 F 9.50” 8.90” 1.30” 1.00”
32 IS 120 50176 EP232IS/120/MC 0.34 38 0.94 1.01 <32 0°F 1-3 F 9.50” 8.90” 1.30” 1.00”
32 IS 120 50115 EP232IS/H/MV/HE 0.37 45 0.98 1.38 <10 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50115 EP232IS/H/MV/HE 0.17 45 0.97 1.38 <15 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50119 EP232IS/L/MV/HE 0.26 31 0.98 0.93 <10 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50119 EP232IS/L/MV/HE 0.12 30 0.95 0.93 <15 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50123 EP232IS/MV/HE 0.29 35 0.98 1.08 <10 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50123 EP232IS/MV/HE 0.13 34 0.97 1.08 <15 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50116 EP232IS/MV/MC 0.32 39 0.98 1.08 <12 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50116 EP232IS/MV/MC 0.14 38 0.97 1.08 <15 0°F 1-3 F 9.50” 8.90” 1.30” 1.10”
32 PS 120 50180 EP232PS/MV/HE 0.31 37 0.98 0.99 <10 0°F 1-11 F 9.50” 8.90” 1.38” 1.18”
32 PS 277 50180 EP232PS/MV/HE 0.14 37 0.93 0.99 <10 0°F 1-11 F 9.50” 8.90” 1.38” 1.18”
32 PS 120 50178 EP232PS/L/MV/HE 0.28 33 0.99 0.86 <10 0°F 1-11 F 9.50” 8.90” 1.38” 1.18”
32 PS 277 50178 EP232PS/L/MV/HE 0.12 33 0.98 0.86 <10 0°F 1-11 F 9.50” 8.90” 1.38” 1.18”
2
32 IS 120 50118 E232IS/120/R/MC 0.80 54 0.56 0.85 <130 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50176 EP232IS/120/MC 0.49 59 0.97 0.87 <30 0°F 2-17 F 9.50” 8.90” 1.30” 1.00”
32 IS 120 50115 EP232IS/H/MV/HE 0.62 74 0.98 1.18 <10 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50115 EP232IS/H/MV/HE 0.27 73 0.98 1.18 <10 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50119 EP232IS/L/MV/HE 0.40 49 0.98 0.78 <10 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50119 EP232IS/L/MV/HE 0.18 48 0.97 0.78 <15 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50123 EP232IS/MV/HE 0.46 56 0.98 0.89 <10 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50123 EP232IS/MV/HE 0.20 55 0.97 0.89 <10 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50116 EP232IS/MV/MC 0.50 59 0.98 0.89 <10 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50116 EP232IS/MV/MC 0.21 57 0.98 0.89 <10 0°F 2-17 F 9.50” 8.90” 1.30” 1.10”
32 PS 120 50180 EP232PS/MV/HE 0.50 60 0.99 0.88 <10 0°F 2-24 F 9.50” 8.90” 1.38” 1.18”
32 PS 277 50180 EP232PS/MV/HE 0.22 60 0.98 0.88 <10 0°F 2-24 F 9.50” 8.90” 1.38” 1.18”
32 PS 120 50178 EP232PS/L/MV/HE 0.44 52 0.99 0.77 <10 0°F 2-24 F 9.50” 8.90” 1.38” 1.18”
32 PS 277 50178 EP232PS/L/MV/HE 0.19 52 0.98 0.77 <10 0°F 2-24 F 9.50” 8.90” 1.38” 1.18”
32 IS 120 50121 EP332IS/H/MV/HE 0.69 81 0.98 1.27 <10 0°F 2-11 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50121 EP332IS/H/MV/HE 0.30 80 0.98 1.27 <10 0°F 2-11 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50168 EP332IS/L/MV/HE 0.49 58 0.98 0.92 <10 0°F 2-11 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50168 EP332IS/L/MV/HE 0.21 57 0.95 0.92 <15 0°F 2-11 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50170 EP332IS/MV/HE 0.53 63 0.98 0.99 <10 0°F 2-11 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50170 EP332IS/MV/HE 0.24 63 0.97 0.99 <15 0°F 2-11 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50122 EP332IS/MV/MC 0.53 63 0.98 0.97 <10 0°F 2-11 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50122 EP332IS/MV/MC 0.24 63 0.97 0.97 <15 0°F 2-11 F 9.50” 8.90” 1.30” 1.10”
T8
Case diagrams and wiring diagrams can be found on pages 190-192.
TOC
ElEctronic FluorEscEnt Ballasts
188
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Case diagrams and wiring diagrams can be found on pages 190-192.
F32T8, FB32, FB31
continued
3
32 IS 120 50158 E432IS/R/120/MC 1.35 86 0.50 0.90 <170 0°F 3-9 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50121 EP332IS/H/MV/HE 0.91 108 0.98 1.18 <10 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50121 EP332IS/H/MV/HE 0.39 106 0.98 1.18 <10 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50168 EP332IS/L/MV/HE 0.64 76 0.98 0.78 <10 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50168 EP332IS/L/MV/HE 0.27 74 0.98 0.78 <10 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50170 EP332IS/MV/HE 0.71 84 0.98 0.88 <10 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50170 EP332IS/MV/HE 0.31 83 0.98 0.88 <10 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50122 EP332IS/MV/MC 0.71 84 0.98 0.86 <10 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50122 EP332IS/MV/MC 0.31 83 0.98 0.86 <10 0°F 3-7 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50124 EP432IS/120/MC 0.79 94 0.98 1.00 <20 0°F 3-9 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50172 EP432IS/L/MV/HE 0.68 81 0.98 0.82 <10 0°F 3-9 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50172 EP432IS/L/MV/HE 0.29 80 0.98 0.82 <10 0°F 3-9 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50174 EP432IS/MV/HE 0.77 92 0.98 0.96 <10 0°F 3-9 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50174 EP432IS/MV/HE 0.34 89 0.98 0.96 <10 0°F 3-9 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50126 EP432IS/MV/MC 0.77 92 0.98 0.92 <10 0°F 3-9 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50126 EP432IS/MV/MC 0.34 89 0.98 0.92 <10 0°F 3-9 F 9.50” 8.90” 1.30” 1.10”
32 PS 120 50184 EP432PS/MV/HE 0.79 95 0.99 0.92 <10 0°F 3-8 F 9.50” 8.90” 1.65” 1.18”
32 PS 277 50184 EP432PS/MV/HE 0.35 95 0.98 0.93 <10 0°F 3-8 F 9.50” 8.90” 1.65” 1.18”
32 PS 120 50182 VEP432PS/L/MV/HE 0.66 78 0.99 0.78 <10 0°F 3-8 F 9.50” 8.90” 1.65” 1.18”
32 PS 277 50182 VEP432PS/L/MV/HE 0.29 78 0.98 0.79 <10 0°F 3-8 F 9.50” 8.90” 1.65” 1.18”
4
32 IS 120 50158 E432IS/120/R/MC 1.62 103 0.50 0.82 <165 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50124 EP432IS/120/MC 0.93 110 0.98 0.88 <20 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50172 EP432IS/L/MV/HE 0.82 98 0.98 0.77 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50172 EP432IS/L/MV/HE 0.35 96 0.98 0.77 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50174 EP432IS/MV/HE 0.93 112 0.99 0.88 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50174 EP432IS/MV/HE 0.40 109 0.99 0.88 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
32 IS 120 50126 EP432IS/MV/MC 0.93 112 0.98 0.85 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
32 IS 277 50126 EP432IS/MV/MC 0.40 108 0.98 0.85 <10 0°F 4-6 F 9.50” 8.90” 1.30” 1.10”
32 PS 120 50184 EP432PS/MV/HE 0.95 114 0.99 0.86 <10 0°F 4-5 F 9.50” 8.90” 1.65” 1.18”
32 PS 277 50184 EP432PS/MV/HE 0.42 114 0.98 0.86 <10 0°F 4-5 F 9.50” 8.90” 1.65” 1.18”
32 PS 120 50182 VEP432PS/L/MV/HE 0.82 97 0.99 0.74 <10 0°F 4-5 F 9.50” 8.90” 1.65” 1.18”
32 PS 277 50182 VEP432PS/L/MV/HE 0.35 97 0.99 0.74 <10 0°F 4-5 F 9.50” 8.90” 1.65” 1.18”
V Item will be discontinued when inventory is depleted.
T8
TOC
ElEctronic FluorEscEnt Ballasts
189
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Case diagrams and wiring diagrams can be found on pages 190-192.
V Item will be discontinued when inventory is depleted.
F40T8
1
40 IS 120 50176 EP232IS/120/MC 0.39 45 0.96 1.00 <30 32°F 1-3 F 9.50” 8.90” 1.30” 1.00”
40 IS 120 50115 EP232IS/H/MV/HE 0.45 54 0.98 1.35 <10 32°F 1-3 F 9.50” 8.90” 1.30” 1.10”
40 IS 277 50115 EP232IS/H/MV/HE 0.20 54 0.97 1.35 <15 32°F 1-3 F 9.50” 8.90” 1.30” 1.10”
40 IS 120 50119 EP232IS/L/MV/HE 0.30 35 0.98 0.90 <10 32°F 1-3 F 9.50” 8.90” 1.30” 1.10”
40 IS 277 50119 EP232IS/L/MV/HE 0.13 35 0.95 0.90 <15 32°F 1-3 F 9.50” 8.90” 1.30” 1.10”
40 IS 120 50123 EP232IS/MV/HE 0.35 44 0.98 1.00 <10 32°F 1-3 F 9.50” 8.90” 1.30” 1.10”
40 IS 277 50123 EP232IS/MV/HE 0.16 43 0.97 1.00 <15 32°F 1-3 F 9.50” 8.90” 1.30” 1.10”
40 IS 120 50116 EP232IS/MV/MC 0.38 46 0.98 1.00 <10 32°F 1-3 F 9.50” 8.90” 1.30” 1.10”
40 IS 277 50116 EP232IS/MV/MC 0.16 45 0.97 1.00 <15 32°F 1-3 F 9.50” 8.90” 1.30” 1.10”
40 PS 120 50180 EP232PS/MV/HE 0.38 45 0.98 0.99 <10 0°F 1-11 F 9.50” 8.90” 1.38” 1.18”
40 PS 277 50180 EP232PS/MV/HE 0.17 45 0.97 1.01 <10 0°F 1-11 F 9.50” 8.90” 1.38” 1.18”
40
PS 120 50178 EP232PS/L/MV/HE 0.32 38 0.99 0.82 <10 0°F 1-11 F 9.50” 8.90” 1.38” 1.18”
40
PS 277 50178 EP232PS/L/MV/HE 0.14 39 0.98 0.82 <10 0°F 1-11 F 9.50” 8.90” 1.38” 1.18”
2
40 IS 120 50121 EP332IS/H/MV/HE 0.84 100 0.98 1.26 <10 0°F 2-11 F 9.50” 8.90” 1.30” 1.10”
40 IS 277 50121 EP332IS/H/MV/HE 0.37 98 0.98 1.26 <10 0°F 2-11 F 9.50” 8.90” 1.30” 1.10”
40 IS 120 50168 EP332IS/L/MV/HE 0.60 71 0.98 0.87 <10 32°F 2-11 F 9.50” 8.90” 1.30” 1.10”
40 IS 277 50168 EP332IS/L/MV/HE 0.26 70 0.98 0.87 <15 32°F 2-11 F 9.50” 8.90” 1.30” 1.10”
40 IS 120 50170 EP332IS/MV/HE 0.65 78 0.98 0.95 <10 32°F 2-11 F 9.50” 8.90” 1.30” 1.10”
40 IS 277 50170 EP332IS/MV/HE 0.29 77 0.97 0.95 <15 32°F 2-11 F 9.50” 8.90” 1.30” 1.10”
3
40 IS 120 50124 EP432IS/120/MC 0.93 112 0.98 0.88 <20 32°F 3-9 F 9.50” 8.90” 1.30” 1.10”
40 IS 120 50172 EP432IS/L/MV/HE 0.82 98 0.98 0.82 <10 32°F 3-9 F 9.50” 8.90” 1.30” 1.10”
40 IS 277 50172 EP432IS/L/MV/HE 0.35 96 0.98 0.82 <10 32°F 3-9 F 9.50” 8.90” 1.30” 1.10”
40 IS 120 50174 EP432IS/MV/HE 0.95 114 0.98 0.96 <10 32°F 3-9 F 9.50” 8.90” 1.30” 1.10”
40 IS 277 50174 EP432IS/MV/HE 0.41 109 0.98 0.96 <10 32°F 3-9 F 9.50” 8.90” 1.30” 1.10”
40 IS 120 50126 EP432IS/MV/MC 0.95 114 0.98 0.92 <10 32°F 3-9 F 9.50” 8.90” 1.30” 1.10”
40 IS 277 50126 EP432IS/MV/MC 0.41 109 0.98 0.92 <10 32°F 3-9 F 9.50” 8.90” 1.30” 1.10”
40 PS 120 50184 EP432PS/MV/HE 0.93 111 0.99 0.88 <10 0°F 3-8 F 9.50” 8.90” 1.65” 1.18”
40 PS 277 50184 EP432PS/MV/HE 0.41 111 0.98 0.89 <10 0°F 3-8 F 9.50” 8.90” 1.65” 1.18”
40 PS 120 50182 VEP432PS/L/MV/HE 0.83 99 0.99 0.77 <10 0°F 3-8 F 9.50” 8.90” 1.65” 1.18”
40 PS 277 50182 VEP432PS/L/MV/HE 0.36 99 0.99 0.79 <10 0°F 3-8 F 9.50” 8.90” 1.65” 1.18”
F96T8
159 IS 120 50136 EP259IS/MV 0.57 68 0.98 1.04 <10 32°F 1-3 F 9.50” 8.90” 1.30” 1.10”
59 IS 277 50136 EP259IS/MV 0.25 67 0.98 1.04 <10 32°F 1-3 F 9.50” 8.90” 1.30” 1.10”
259 IS 120 50136 EP259IS/MV 0.92 108 0.98 0.83 <10 32°F 2-17 F 9.50” 8.90” 1.30” 1.10”
59 IS 277 50136 EP259IS/MV 0.40 106 0.98 0.83 <10 32°F 2-17 F 9.50” 8.90” 1.30” 1.10”
T8
TOC
ELECTRONIC FLUORESCENT BALLASTS
190 Halco Lighting Technologies | 800.677.3334 | halcolighting.com
L
M
H
W
F
LAMP
BALLAST
BLUE
BLUE
BLACK
WHITE
RED
1-3 1-11
1-12
LAMP
RED
BLACK
WHITE
LINE
BALLAST
1-18
BALLAST
RED
RED
BLACK
WHITE
LINE
BLUE
BLUE
LAMP
T8
Wiring Diagrams
Case Diagram
TOC
ElEctronic FluorEscEnt Ballasts
191
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
2-11
LAMP 2
LAMP 1
BALLAST
BLUE
BLUE
RED
BLACK
WHITE
LINE
BLUE
2-12
LAMP 2
BALLAST
BLUE
BLUE RED
BLACK
WHITE
LINE
RED
LAMP 1
RED
RED
BLUE
BLUE
LAMP 1
LAMP 2
BALLAST
BLUE
BLUE
BLACK
WHITE
RED
2-17
2-24
LAMP 2
LAMP 1
1-23
LAMP
BALLAST
BLUE
BLACK
WHITE
RED
LAMP 2
LAMP 1
LAMP 3
BLACK
WHITE
BLUE
RED
BLUE
BLUE
LAMP 2
LAMP 1
LAMP 3
BALLAST
BLACK
WHITE
BLUE
RED
BLUE
BLUE
3-7
T8
Wiring Diagrams
TOC
ELECTRONIC FLUORESCENT BALLASTS
192 Halco Lighting Technologies | 800.677.3334 | halcolighting.com
LAMP 3
LAMP 4
LAMP 1
LAMP 2
BALLAST
RED
RED
BLUE
BLUE
BLACK
WHITE
YELLOW
YELLOW
LAMP 2
LAMP 1
LAMP 3
BALLAST
BLACK
WHITE
RED
RED
BLUE
BLUE
YELLOW
YELLOW
LINE
3-8
BALLAST
RED/WHITE
RED
YELLOW
BLACK
WHITE
LINE
LAMP 2
RED/WHITE
LAMP 1
YELLOW
BLUE
RED
BLUE
BLUE/WHITE
BLUE/WHITE
LAMP 3
3-9
4-5
LAMP 4
LAMP 3
BALLAST
RED/WHITE
RED
YELLOW
BLACK
WHITE
LINE
LAMP 2
RED/WHITE
LAMP 1
YELLOW
BLUE
RED
BLUE
BLUE/WHITE
BLUE/WHITE
4-6
T8
Wiring Diagrams
TOC
ElEctronic FluorEscEnt Ballasts
193
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
FC8T9
122 RS 120 50150 E1CR22RS/120/PT 0.33 21 0.52 0.90 <150 0°F 1-4 H 3.45” 3.12” 1.81” 1.21”
FC16T9
140 PS 120 52106 EP2CF26PS/MV/DC/K 0.34 43 0.99 1.00 <10 0°F 1-13 L 5.00” 4.63” 2.40” 1.00”
40 PS 277 52106 EP2CF26PS/MV/DC/K 0.15 43 0.99 1.00 <10 0°F 1-13 L 5.00” 4.63” 2.40” 1.00”
FC8T9 + FC12T9
222+32 RS 120 50148 *E2CR72RS/120/PT 0.60 40 0.54 0.76 <150 0°F 2-3 F 6.46” 6.00” 1.89” 1.00”
FC12T9 + FC16T9
232+40 RS 120 50148 *E2CR72RS/120/PT 0.75 50 0.53 0.70 <150 0°F 2-3 F 6.46” 6.00” 1.89” 1.00”
*Ballast operates two different lamps together.
T9 Circline
Case diagrams and wiring diagrams can be found on pages 193-194.
H
WL
M
L
H
W
M
L
H
L
M
H
W
F
Case Diagrams
TOC
ELECTRONIC FLUORESCENT BALLASTS
194 Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T9 Circline
BLUE
BLUE
RED
RED
BALLAST
BLACK
WHITE
LINE
FOR POSITIVE STARTING,
SPACE 3 METAL CLIPS 120º
APART AS ILLUSTRATED.
BALLAST
BLACK
WHITE
LINE
BLUE
BLUE
RED
RED
FOR POSITIVE STARTING,
SPACE 3 METAL CLIPS 120º
APARTAS ILLUSTRATED.
RED
RED
BLUE
BLUE
2-3
1-4
1-13
BLACK
WHITE
GREEN
BALLAST
BLUE
BLUE
RED
RED
YEL
YEL
Wiring Diagrams
TOC
ElEctronic FluorEscEnt Ballasts
195
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T12
F14T12
114 RS 120 50108 VE120RS/120 0.24 15.5 0.54 1.00 <150 0°F 1-18 F 6.46” 6.00” 1.37” 1.00”
214 RS 120 50110 E220RS/120 0.42 27 0.54 0.85 <150 0°F 2-12 F 6.46” 6.00” 1.37” 1.00”
F15T12
115 RS 120 50108 VE120RS/120 0.25 16 0.54 1.00 <140 0°F 1-18 F 6.46” 6.00” 1.37” 1.00”
215 RS 120 50110 E220RS/120 0.48 32 0.56 1.02 <150 0°F 2-12 F 6.46” 6.00” 1.37” 1.00”
F20T12
120 RS 120 50108 VE120RS/120 0.26 18 0.56 0.90 <130 0°F 1-18 F 6.46” 6.00” 1.37” 1.00”
220 RS 120 50110 E220RS/120 0.52 36 0.57 0.87 <130 0°F 2-12 F 6.46” 6.00” 1.37” 1.00”
F25T12/48”
1
25 RS 120 50128 EP240RS/120 0.43 51 0.99 1.70 <10 0°F 1-11 F 9.50” 8.90” 1.70” 1.15”
25 RS 120 50160 EP240RS/MV 0.43 51 0.99 1.70 <10 0°F 1-11 F 9.50” 8.90” 1.70” 1.15”
25 RS 277 50160 EP240RS/MV 0.19 51 0.99 1.70 <10 0°F 1-11 F 9.50” 8.90” 1.70” 1.15”
2
25 RS 120 50128 EP240RS/120 0.66 78 0.99 1.40 <10 0°F 2-1 F 9.50” 8.90” 1.70” 1.15”
25 RS 120 50160 EP240RS/MV 0.66 78 0.99 1.40 <10 0°F 2-1 F 9.50” 8.90” 1.70” 1.15”
25 RS 277 50160 EP240RS/MV 0.28 78 0.98 1.40 <10 0°F 2-1 F 9.50” 8.90” 1.70” 1.15”
F30T12
1
30 RS 120 50128 EP240RS/120 0.32 38 0.98 1.00 <10 0°F 1-11 F 9.50” 8.90” 1.70” 1.15”
30 RS 120 50160 EP240RS/MV 0.32 38 0.99 1.00 <10 0°F 1-11 F 9.50” 8.90” 1.70” 1.15”
30 RS 277 50160 EP240RS/MV 0.14 38 0.99 1.00 <10 0°F 1-11 F 9.50” 8.90” 1.70” 1.15”
2
30 RS 120 50128 EP240RS/120 0.49 58 0.99 0.88 <10 0°F 2-1 F 9.50” 8.90” 1.70” 1.15”
30 RS 120 50160 EP240RS/MV 0.49 58 0.99 0.88 <10 0°F 2-1 F 9.50” 8.90” 1.70” 1.15”
30 RS 277 50160 EP240RS/MV 0.22 58 0.97 0.88 <10 0°F 2-1 F 9.50” 8.90” 1.70” 1.15”
F34T12, FB34
1
34 RS 120 50128 EP240RS/120 0.34 40 0.98 1.10 <10 0°F 1-11 F 9.50” 8.90” 1.70” 1.15”
34 RS 120 50160 EP240RS/MV 0.34 40 0.98 1.10 <10 0°F 1-11 F 9.50” 8.90” 1.70” 1.15”
34 RS 277 50160 EP240RS/MV 0.15 40 0.98 1.10 <10 0°F 1-11 F 9.50” 8.90” 1.70” 1.15”
2
34 RS 120 50128 EP240RS/120 0.53 63 0.98 0.85 <10 0°F 2-1 F 9.50” 8.90” 1.70” 1.15”
34 RS 120 50160 EP240RS/MV 0.53 63 0.98 0.85 <10 0°F 2-1 F 9.50” 8.90” 1.70” 1.15”
34 RS 277 50160 EP240RS/MV 0.23 63 0.98 0.85 <10 0°F 2-1 F 9.50” 8.90” 1.70” 1.15”
F40T12, FB40
1
40 RS 120 50128 EP240RS/120 0.40 47 0.99 1.10 <10 0°F 1-11 F 9.50” 8.90” 1.70” 1.15”
40 RS 120 50160 EP240RS/MV 0.40 47 0.99 1.10 <10 0°F 1-11 F 9.50” 8.90” 1.70” 1.15”
40 RS 277 50160 EP240RS/MV 0.17 47 0.99 1.10 <10 0°F 1-11 F 9.50” 8.90” 1.70” 1.15”
2
40 RS 120 50128 EP240RS/120 0.62 74 0.99 0.88 <10 0°F 2-1 F 9.50” 8.90” 1.70” 1.15”
40 RS 120 50160 EP240RS/MV 0.62 74 0.99 0.88 <10 0°F 2-1 F 9.50” 8.90” 1.70” 1.15”
40 RS 277 50160 EP240RS/MV 0.27 74 0.99 0.88 <10 0°F 2-1 F 9.50” 8.90” 1.70” 1.15”
Case diagrams and wiring diagrams can be found on pages 197-199.
V Item will be discontinued when inventory is depleted.
TOC
ElEctronic FluorEscEnt Ballasts
196
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T12
F48T12/ES
230 IS 120 50130 EP275IS/MV 0.60 64 0.95 0.92 <12 60°F 2-4 D 11.70” 11.00” 3.15” 1.85”
30 IS 277 50130 EP275IS/MV 0.26 64 0.95 0.92 <12 60°F 2-4 D 11.70” 11.00” 3.15” 1.85”
F48T12
2
40 IS 120 50132 EP260IS/120 0.62 74 0.98 0.92 <12 0°F 2-4 F 9.50” 8.90” 1.70” 1.15”
40 IS 277 50134 EP260IS/277 0.27 74 0.98 0.92 <12 0°F 2-4 F 9.50” 8.90” 1.70” 1.15”
40 IS 120 50130 EP275IS/MV 0.68 76 0.95 0.92 <10 0°F 2-4 D 11.70” 11.00” 3.15” 1.85”
40 IS 277 50130 EP275IS/MV 0.30 76 0.95 0.92 <10 0°F 2-4 D 11.70” 11.00” 3.15” 1.85”
F48T12/HO
2
60 RS 120 50162 EP2110RS/120 0.88 104 0.99 0.90 <10 -20°F 2-1 A 11.80” 11.00” 2.15” 1.61”
60 RS 120 50164 EP2110RS/MV 0.88 104 0.99 0.90 <20 -20°F 2-1 A 11.80” 11.00” 2.15” 1.61”
60 RS 277 50164 EP2110RS/MV 0.38 104 0.95 0.90 <20 -20°F 2-1 A 11.80” 11.00” 2.15” 1.61”
F60T12/HO
2
75 RS 120 50162 EP2110RS/120 1.10 132 0.99 0.90 <10 -20°F 2-1 A 11.80” 11.00” 2.15” 1.61”
75 RS 120 50164 EP2110RS/MV 1.10 132 0.99 0.90 <10 -20°F 2-1 A 11.80” 11.00” 2.15” 1.61”
75 RS 277 50164 EP2110RS/MV 0.48 132 0.96 0.90 <10 -20°F 2-1 A 11.80” 11.00” 2.15” 1.61”
F72T12
157 IS 120 50130 EP275IS/MV 0.60 67 0.95 1.05 <12 0°F 1-12 D 11.70” 11.00” 3.15” 1.85”
57 IS 277 50130 EP275IS/MV 0.26 67 0.95 1.05 <12 0°F 1-12 D 11.70” 11.00” 3.15” 1.85”
2
57 IS 120 50132 EP260IS/120 0.90 106 0.98 0.95 <12 0°F 2-4 F 9.50” 8.90” 1.70” 1.15”
57 IS 277 50134 EP260IS/277 0.39 106 0.98 0.95 <12 0°F 2-4 F 9.50” 8.90” 1.70” 1.15”
57 IS 120 50130 EP275IS/MV 0.92 107 0.95 0.95 <12 0°F 2-4 D 11.70” 11.00” 3.15” 1.85”
57 IS 277 50130 EP275IS/MV 0.40 107 0.95 0.95 <12 0°F 2-4 D 11.70” 11.00” 3.15” 1.85”
F72T12/HO
2
85 RS 120 50162 EP2110RS/120 1.30 154 0.99 0.90 <10 -20°F 2-1 A 11.80” 11.00” 2.15” 1.61”
85 RS 120 50164 EP2110RS/MV 1.30 154 0.99 0.90 <20 -20°F 2-1 A 11.80” 11.00” 2.15” 1.61”
85 RS 277 50164 EP2110RS/MV 0.56 154 0.97 0.90 <20 -20°F 2-1 A 11.80” 11.00” 2.15” 1.61”
F96T12/ES
160 IS 120 50130 EP275IS/MV 0.60 71 0.98 1.12 <12 60°F 1-12 D 11.70” 11.00” 3.15” 1.85”
60 IS 277 50130 EP275IS/MV 0.27 72 0.98 1.12 <12 60°F 1-12 D 11.70” 11.00” 3.15” 1.85”
2
60 IS 120 50132 EP260IS/120 0.97 115 0.98 0.95 <12 60°F 2-4 F 9.50” 8.90” 1.70” 1.15”
60 IS 277 50134 EP260IS/277 0.42 115 0.98 0.95 <12 60°F 2-4 F 9.50” 8.90” 1.70” 1.15”
60 IS 120 50130 EP275IS/MV 0.97 115 0.99 0.95 <10 60°F 2-4 D 11.70” 11.00” 3.15” 1.85”
60 IS 277 50130 EP275IS/MV 0.42 115 0.98 0.95 <10 60°F 2-4 D 11.70” 11.00” 3.15” 1.85”
Case diagrams and wiring diagrams can be found on pages 197-199.
TOC
ELECTRONIC FLUORESCENT BALLASTS
197
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T12
F96T12
175 IS 120 50130 EP275IS/MV 0.69 83 0.99 1.05 <12 0°F 1-12 D 11.70” 11.00” 3.11” 1.85”
75 IS 277 50130 EP275IS/MV 0.31 83 0.98 1.05 <12 0°F 1-12 D 11.70” 11.00” 3.11” 1.85”
275 IS 120 50130 EP275IS/MV 1.15 133 0.99 0.86 <12 0°F 2-4 D 11.70” 11.00” 3.11” 1.85”
75 IS 277 50130 EP275IS/MV 0.49 133 0.99 0.86 <12 0°F 2-4 D 11.70” 11.00” 3.11” 1.85”
F96T12/HO/ES
2
95 RS 120 50162 EP2110RS/120 1.38 164 0.99 0.90 <10 60°F 2-1 A 11.80” 11.00” 2.15” 1.61”
95 RS 120 50164 EP2110RS/MV 1.38 164 0.98 0.90 <20 60°F 2-1 A 11.80” 11.00” 2.15” 1.61”
95 RS 277 50164 EP2110RS/MV 0.60 164 0.97 0.90 <20 60°F 2-1 A 11.80” 11.00” 2.15” 1.61”
F96T12/HO
1
110 RS 120 50162 EP2110RS/120 0.88 104 0.99 0.92 <15 -20°F 1-7 A 11.80” 11.00” 2.15” 1.61”
110 RS 120 50164 EP2110RS/MV 0.88 104 0.99 0.92 <20 -20°F 1-7 A 11.80” 11.00” 2.15” 1.61”
110 RS 277 50164 EP2110RS/MV 0.38 104 0.95 0.92 <20 -20°F 1-7 A 11.80” 11.00” 2.15” 1.61”
2
110 RS 120 50162 EP2110RS/120 1.65 196 0.99 0.90 <10 -20°F 2-1 A 11.80” 11.00” 2.15” 1.61”
110 RS 120 50164 EP2110RS/MV 1.65 196 0.99 0.90 <10 -20°F 2-1 A 11.80” 11.00” 2.15” 1.61”
110 RS 277 50164 EP2110RS/MV 0.71 196 0.98 0.90 <10 -20°F 2-1 A 11.80” 11.00” 2.15” 1.61”
Case diagrams and wiring diagrams can be found on pages 197-199.
W
H
L
M
D
A
L
M
H
W
F
Case Diagrams
TOC
ELECTRONIC FLUORESCENT BALLASTS
198 Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T12
Wiring Diagrams
BALLAST
BLUE
BLUE
BLACK
WHITE
LINE
RED
RED
LAMP
1-7 1-11
1-12
LAMP
RED
BLACK
WHITE
LINE
BALLAST
1-18
BALLAST
RED
RED
BLACK
WHITE
LINE
BLUE
BLUE
LAMP
TOC
ELECTRONIC FLUORESCENT BALLASTS
199
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T12
2-12
LAMP 2
BALLAST
BLUE
BLUE RED
BLACK
WHITE
LINE
RED
LAMP 1
RED
RED
BLUE
BLUE
LAMP 2
LAMP 1
2-1
LAMP 2
LAMP 1
BALLAST
BLUE
BLUE
RED
BLACK
WHITE
LINE
2-4
Wiring Diagrams
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Cross Reference Guide
200
ELECTRONIC FLUORESCENT BALLASTS
HALCO ADVANCE UNIVERSAL/
MAGNETEK HOWARD
E114RS/120 - - -
E120RS/120 - - -
E220RS/120 - - -
EP2110RS/120 - B295SR120HP E2/110RS-120
EP2110RS/MV ICN-2S110-SC B295SRUNVHP EP2/110RS-MV
EP228PS/MV/MC ICN-2S28-N B228PUNV-N EP2/28T5/PRS/MV
EP132IS/MV/MC ICN-1P32-N B132IUNVHP-N -
E232IS/120/R/MC REB-2P32-SC B232I120RES-G E2/32IS-120MC
EP232IS/120/MC - B232I120RH-A EP2/32IS-120MC
EP232IS/MV/MC ICN-2P32-N B232IUNVHP-N EP2/32IS/MV/MC
EP232IS/H/MV/HE IOPA-2P32-HL-N B232IUNVHEH-A EPH2/32IS/MV/MC/HE
EP232IS/L/MV/HE IOPA-2P32-LW-N B232IUNVEL-A EPL2/32IS/MV/MC/HE
EP232IS/MV/HE IOPA-2P32-N B232IUNVHE-A EP2/32IS/MV/MC/HE
EP232PS/MV/HE IOP-2PSP32-SC B232PUNVHE-B EP2/PRS/MV/MC/HE
EP232PS/L/MV/HE IOP-2PSP32-LW-SC B232PUNVEL-B -
EP239HO/PS/MV ICN-2S39 B239PUNV-D EP2/39HO/PRS/MV
EP240RS/120 RELB-2S40-N B240R120HP E2/40RS-120MC
EP240RS/MV ICN-2S40-N - EP2/40RS/MV/MC
EP254HO/PS/MV ICN-2S54 B254PUNV-D EP2/54HO/PRS/MV/90CW
EP254HO/PS/MV/MC ICN-2S54-N - EP2/54HO/PRS/MV/W/MC
EP259IS/MV IOP-2P59-SC B259IUNVHP-A EP2/59IS/MV/MC
EP260IS/120 - B260I120M-A -
EP260IS/277 - - -
EP275IS/MV ICN-2P60-SC B260IUNVHP EP2/75IS/MV/SC
EP332IS/MV/MC ICN-3P32-N B332IUNVHP-A -
EP332IS/H/MV/HE IOPA-3P32-HL-N B332IUNVHEH-A -
EP332IS/L/MV/HE IOPA-3P32-LW-N B332IUNVEL-A EPL3/32IS/MV/SC/HE
EP332IS/MV/HE IOPA-3P32-N B332IUNVHE-A EP3/32IS/MV/MC/HE
E432IS/120/R/SL REB-4P32-SC B432I120RES-A -
EP432IS/120/SL - B432I120RH-A -
EP432IS/MV/MC ICN-4P32-N B432IUNVHP-A -
EP432IS/L/MV/HE IOPA-4P32-LW-N B432IUNVEL-A EPL4/32IS/MV/MC/HE
EP432IS/MV/HE IOPA-4P32-N B432IUNVHE-A EP4/32IS/MV/MC/HE
EP432PS/MV/HE IOP-4PSP32-SC B432PUNVHE-A EP4/32PPRS/MV/SC/HE
EP432PS/L/MV/HE IOP-4PSP32LW-SC B432PUNVEL-A -
EP454HO/PS/MV IOP-4PSP54-2LS-G B454PUNV-E -
E1CR22RS/120/PT - - -
E2CR72RS/120/PT - - -
TOC
ElEctronic FluorEscEnt Ballasts
201
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Specications
SPECIFICATIONS
Ballast shall have a Lamp Current Crest Factor of <1.7 in accordance with ANSI C82.1.
Ballast shall withstand line voltage transients and surges as specied in ANSI standard
C62.41-1991.
Ballast shall have an Underwriters Laboratories certication for operation in the US and
either an Underwriters Laboratories or Canadian Standards Association certication for
operation in Canada.
Ballast shall comply with the EMI and RFI limits of the code of Federal Regulations, Title 47,
Part 18C for Non-Consumer equipment.
Ballast shall operate in the range of 50-60Hz input frequency.
Ballast shall operate at a maximum of 18 feet remote mounting distance for primary lamp.
For energy saving reduced wattages lamps, remote mounting distances will be shorter.
Ballast shall operate at a frequency of 20-40 kHz.
Ballast shall contain potting compound in order to protect from moisture, dissipate heat and
provide stability.
All ProFormance ballasts shall have a power factor of 0.98 or better on the primary lamp
conguration.
Ballast shall be sound rated Class A.
Ballast shall have a minimum starting temperature of 0˚F standard lamps and 60°F on
Energy Saving lamps.
Ballast shall tolerate sustained variations of +/-10% of supply voltage with
no damage to the ballast.
Ballast shall not contain PCBs.
Manufacturer shall provide written warranty against defects in material or workmanship
for 5 years from date of manufacture.
TOC
ELECTRONIC FLUORESCENT BALLAST
202
E114RS/120
50104
Lamp Type # of
Lamps
F14T5 1
F6T5 2
F8T5 2
F13T5 1
F21T5 1
PL13D/E/G24q 1
PL13T/E/G24q 1
E120RS/120
50108
Lamp Type # of
Lamps
F20T12 1
F20T8 1
F18T8 24" 1
F17T8 1
F15T12 1
F15T8 1
F14T12 1
F14T8 1
E154HO/RS/120
50140
Lamp Type # of
Lamps
F54T5/HO 1
PLL55/RS/2G11 1
E220RS/120
50110
Lamp Type # of
Lamps
F20T12 2
F20T8 2
F18T8 24" 2
F17T8 2
F15T12 2
F15T8 2
F14T12 2
F14T8 2
E232IS/120/R/MC
50118
Lamp Type # of
Lamps
F32T8 1, 2
F25T8 1, 2
F17T8 1, 2
F40T8 1
E432IS/120/R/SL
50158
Lamp Type # of
Lamps
F32T8 3, 4
F28T8 3, 4
F25T8 3, 4
F17T8 3, 4
EP132IS/MV/MC
50112
Lamp Type # of
Lamps
F32T8 1
F28T8 1
F25T8 1
F17T8 1
F40T8 1
EP2110RS/120
50162
Lamp Type # of
Lamps
F96T12/HO 1, 2
F96T12/HO/ES 2
F72T12/HO 2
F60T12/HO 2
F48T12/HO 2
EP2110RS/MV
50164
Lamp Type # of
Lamps
F96T12/HO 1, 2
F96T12/HO/ES 2
F72T12/HO 2
F60T12/HO 2
F48T12/HO 2
EP228PS/MV/MC
52112
Lamp Type # of
Lamps
F35T5 1, 2
F28T5 1, 2
F21T5 1, 2
F14T5 1, 2
EP232IS/120/MC
50176
Lamp Type # of
Lamps
F32T8 1, 2
F25T8 1, 2
F17T8 1, 2
F40T8 1
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Lamp Compatibility Specications
TOC
ELECTRONIC FLUORESCENT BALLAST
Lamp Compatibility Specications
203
EP232IS/L/MV/HE
50119
Lamp Type # of
Lamps
F32T8 1, 2
F28T8 1, 2
F25T8/ES 1, 2
F25T8 1, 2
F17T8 1, 2
F40T8 1
EP232IS/MV/HE
50123
Lamp Type # of
Lamps
F32T8 1, 2
F28T8 1, 2
F25T8/ES 1, 2
F25T8 1, 2
F17T8 1, 2
F40T8 1
EP232IS/MV/MC
50116
Lamp Type # of
Lamps
F32T8 1, 2
F28T8 1, 2
F25T8 1, 2
F17T8 1, 2
F40T8 1
EP232IS/H/MV/HE
50115
Lamp Type # of
Lamps
F32T8 1, 2
F28T8 1, 2
F28T8/ES 1,2
F25T8 1, 2
F17T8 1, 2
F40T8 1
EP232PS/L/MV/HE
50178
Lamp Type # of
Lamps
F32T8 1, 2
F28T8 1, 2
F25T8/ES 1, 2
F25T8 1, 2
F17T8 1, 2
F40T8 1
EP232PS/MV/HE
50180
Lamp Type # of
Lamps
F32T8 1, 2
F28T8 1, 2
F25T8/ES 1, 2
F25T8 1, 2
F17T8 1, 2
F40T8 1
EP239HO/PS/MV
50142
Lamp Type # of
Lamps
F39T5/HO 1, 2
F24T5/HO 1, 2
PLL40/2G11 1, 2
PLL36/2G11 1, 2
PLL24/2G11 1, 2
FC40T5 1, 2
FC22T5 1, 2
FC22T5 + FC40T5 2
EP240RS/120
50128
Lamp Type # of
Lamps
F40T12 1, 2
F34T12 1, 2
F25T12/48" 1, 2
F30T12 1, 2
EP240RS/MV
50160
Lamp Type # of
Lamps
F40T12 1, 2
F34T12 1, 2
F25T12/48” 1, 2
F30T12 1, 2
EP254HO/PS/MV
50144
Lamp Type # of
Lamps
F54T5/HO 1, 2
PLL55/2G11 1, 2
PLL50/2G11 1, 2
FC55T5/HO 1, 2
EP259IS/MV
50136
Lamp Type # of
Lamps
F96T8 1, 2
EP254HO/PS/MV/MC
52114
Lamp Type # of
Lamps
F54T5/HO 1, 2
F49T5/HO 1, 2
PLL55/2611 1, 2
PLL50/2611 1, 2
Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOC
ELECTRONIC FLUORESCENT BALLAST
Lamp Compatibility Specications
204
EP260IS/277
50134
Lamp Type # of
Lamps
F96T12/ES 2
F72T12 2
F48T12 2
F96T12/HO 1
EP275IS/MV
50130
Lamp Type # of
Lamps
F96T12 1, 2
F96T12/ES 1, 2
F72T12 1, 2
F48T12 1, 2
F48T12/ES 1, 2
EP332IS/H/MV/SL
50121
Lamp Type # of
Lamps
F32T8 2, 3
F28T8 2, 3
F25T8/ES 2, 3
F25T8 2, 3
F17T8 2, 3
F40T8 2
EP332IS/L/MV/HE
50168
Lamp Type # of
Lamps
F32T8 2, 3
F28T8 2, 3
F25T8/ES 2, 3
F25T8 2, 3
F17T8 2, 3
F40T8 2
EP332IS/MV/HE
50170
Lamp Type # of
Lamps
F32T8 2, 3
F28T8 2, 3
F25T8/ES 2, 3
F25T8 2, 3
F17T8 2, 3
F40T8 2
EP332IS/MV/MC
50122
Lamp Type # of
Lamps
F32T8 2, 3
F28T8 2, 3
F25T8 2, 3
F17T8 2, 3
F40T8 2, 3
EP260IS/120
50132
Lamp Type # of
Lamps
F96T12/ES 2
F72T12 2
F48T12 2
F96T12/HO 1
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
ELECTRONIC FLUORESCENT BALLAST
Lamp Compatibility Specications
205
EP432IS/MV/HE
50174
Lamp Type # of
Lamps
F32T8 3, 4
F28T8 3, 4
F25T8/ES 3, 4
F25T8 3, 4
F17T8 3, 4
F40T8 3
EP432IS/MV/MC
50126
Lamp Type # of
Lamps
F32T8 3, 4
F28T8 3, 4
F25T8 3, 4
F17T8 3, 4
F40T8 3
PLL40/2G11 3
EP432PS/L/MV/HE
50182
Lamp Type # of
Lamps
F32T8 3, 4
F28T8 3, 4
F25T8/ES 3, 4
F25T8 3, 4
F17T8 3, 4
F40T8 3
EP432PS/MV/HE
50184
Lamp Type # of
Lamps
F32T8 3, 4
F28T8 3, 4
F25T8/ES 3, 4
F25T8 3, 4
F17T8 3, 4
F40T8 3
E1CR22RS/120/PT
50150
Lamp Type # of
Lamps
FC8T9 1
EP454HO/PS/MV
50186
Lamp Type # of
Lamps
F54T5/HO 1, 2, 3, 4
F49T5/HO 2, 3, 4
PLL50/2G11 3, 4
E1CR32RS/120/PT
50146
Lamp Type # of
Lamps
FC12T9 1
FC9T9/30W 1
E2CR72RS/120/PT
50148
Lamp Type # of
Lamps
FC12T9 + FC16T9 2
FC8T9 + FC12T9 2
EP432IS/120/SL
50124
Lamp Type # of
Lamps
F32T8 3, 4
F28T8 3, 4
F25T8 3, 4
F17T8 3, 4
F40T8 3
PLL40/2G11 3
EP432IS/L/MV/HE
50172
Lamp Type # of
Lamps
F32T8 3, 4
F28T8 3, 4
F25T8/ES 3, 4
F25T8 3, 4
F17T8 3, 4
F40T8 3
Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOC
ELECTRONIC SIGN BALLASTS
How To Read a Table
T8/HO Sign Ballasts
T12/HO Sign Ballasts
Case Dimensions and Wiring Diagrams
Cross Reference Guide
Lamp Compatibility Specications
208
209
209
210
211
211
CONTENTS
®
main
TOC
HOW TO READ AN ELECTRONIC SIGN
BALLAST TABLE
Lamp Data
Input Volts Product
Number Product Code Max Line
Current (Amps)
Max Input
Power (Watts)
Open
Circuit Volts
Min Starting
Temp Wiring Diag. Case
Diagram
Weight
(Ibs.)
Number of
lamps
Lamp
Footage
Min Max
T8/HO
1, 2 4’ 12’ 120 57114 ESB/0216/12 1.10 122 800 -20°F 1-3, 2-17 D2 2.88
1, 2 4’ 12’ 277 57114 ESB/0216/12 0.45 121 800 -20°F 1-3, 2-17 D2 2.88
1, 2, 3, 4 4’ 24’ 120 57116 ESB/0432/14 2.20 244 800 -20°F 1-17, 2-19, 3-6, 4-3 D3 4.46
1, 2, 3, 4 4’ 24’ 277 57116 ESB/0432/14 0.90 242 800 -20°F 1-17, 2-19, 3-6, 4-3 D3 4.46
NUMBER OF LAMPS
Species the number of lamps the
ballast will operate.
INPUT
VOLTS
Voltage required
from a power
supply for
proper ballast
operation.
OPEN
CIRCUIT
VOLTS
The voltage required
to start a lamp, which
is provided by a
ballast to the lamp’s
electrodes.
PRODUCT CODE
Abbreviated product description
can also be used for ordering.
LAMP TYPE
Indicates the type
of lamp that the
ballast will operate.
PRODUCT
NUMBER
Use this number when
placing an order.
CASE
DIAGRAM
Representation
of the ballast‘s
case.
WIRING
DIAGRAM
References the wiring
diagram to use.
MIN STARTING TEMP.
References minimum ambient
temperature that the ballast will
reliably start a lamp.
LAMP
FOOTAGE
(Min/Max)
Species the
minimum and
maximum total
lamp length per
ballast.
MAX LINE
CURRENT
The current that
results when the
line voltage is
applied to a load.
MAX INPUT
POWER
Total power input
to the ballast
which includes
lamp watts and
ballast losses.
WEIGHT
(lbs.)
Indicates the
ballast’s weight.
TOC
209
ELECTRONIC SIGN BALLASTS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T8/T12 High Output
Lamp Data
Input
Volts
Product
Number Product Code Max Line
Current (Amps)
Max Input
Power (Watts)
Open
Circuit Volts
Min Starting
Temp Wiring Diagrams Case
Diagram
Weight
(Ibs.)
Number of
lamps
Lamp
Footage
Min Max
T8/HO
1, 2 4’ 12’ 120 57114 ESB/0216/12 1.10 122 800 -20°F 1-3, 2-17 D2 2.88
1, 2 4’ 12’ 277 57114 ESB/0216/12 0.45 121 800 -20°F 1-3, 2-17 D2 2.88
1, 2, 3, 4 4’ 24’ 120 57116 ESB/0432/14 2.20 244 800 -20°F 1-17, 2-19, 3-6, 4-3 D3 4.46
1, 2, 3, 4 4’ 24’ 277 57116 ESB/0432/14 0.90 242 800 -20°F 1-17, 2-19, 3-6, 4-3 D3 4.46
1, 2, 3, 4 8’ 32’ 120 57118 ESB/1040/14 2.80 330 1000 -20°F 1-16, 2-18, 3-5, 4-2 D4 7.00
1, 2, 3, 4 8’ 32’ 277 57118 ESB/1040/14 1.25 325 1000 -20°F 1-16, 2-18, 3-5, 4-2 D4 7.00
4, 5, 6 16’ 36’ 120 57120 ESB/0848/46 3.30 370 860 -20°F 4-4, 5-1, 6-1 D4 7.02
4, 5, 6 16’ 36’ 277 57120 ESB/0848/46 1.36 365 860 -20°F 4-4, 5-1, 6-1 D4 7.02
T12/HO
1, 2
2’ 16’ 120 57114
ESB/0216/12
1.20 131 800
-20°
F
1-3, 2-17
D2 2.88
1, 2
2’ 16’ 277 57114
ESB/0216/12
0.50 132 800
-20°
F
1-3, 2-17
D2 2.88
1, 2, 3, 4
4’ 32’ 120 57116
ESB/0432/14
2.40 267 800
-20°
F
1-17, 2-19, 3-6, 4-3
D3 4.46
1, 2, 3, 4
4’ 32’ 277 57116
ESB/0432/14
1.00 267 800
-20°
F
1-17, 2-19, 3-6, 4-3
D3 4.46
1, 2, 3, 4
10’ 40’ 120 57118
ESB/1040/14
3.00 352 1000
-20°
F
1-16, 2-18, 3-5, 4-2
D4 7.00
1, 2, 3, 4
10’ 40’ 277 57118
ESB/1040/14
1.30 349 1000
-20°
F
1-16, 2-18, 3-5, 4-2
D4 7.00
4, 5, 6
8’ 48’ 120 57120
ESB/0848/46
3.50 410 860
-20°
F
4-4, 5-1, 6-1
D4 7.02
4, 5, 6
8’ 48’ 277 57120
ESB/0848/46
1.50 405 860
-20°
F
4-4, 5-1, 6-1
D4 7.02
Total Lamp Footage
Number of Lamps Per
Ballast
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
1, 2
ESB/0216/12
1, 2, 3, 4
ESB/0432/14
1, 2, 3, 4
ESB/1040/14
4, 5, 6
ESB/0848/46
T8 FooTage CharT
Total Lamp Footage
Number of Lamps Per
Ballast
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
1, 2
ESB/0216/12
1, 2, 3, 4
ESB/0432/14
1, 2, 3, 4
ESB/1040/14
4, 5, 6
ESB/0848/46
T12 FooTage CharT
See following page for case dimensions and wiring diagrams.
TOC
210
ELECTRONIC SIGN BALLASTS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
T8/T12 High Output
LAMP
BALLAST
RED
RED
BLUE
BLUE
BLACK
WHITE
YELLOW
/ BLACK
YELLOW
1-16
LAMP 2
LAMP 1
BALLAST
RED
RED
BLUE
BLUE
BLACK
WHITE
YELLOW
/ BLACK
YELLOW
2-18
BALLAST
RED
RED
BLUE
BLUE
BLACK
WHITE
YELLOW
YELLOW
/ BLACK
LAMP 2
LAMP 1
LAMP 3
3-6
BALLAST
RED
RED
BLUE
BLUE
BLACK
WHITE
YELLOW
/ BLACK
YELLOW
BLUE
RED
LAMP 3
LAMP 4
LAMP 1
LAMP 2
4-4
LAMP
BALLAST
BLUE
BLUE
BLACK
WHITE
RED
1-3
LAMP 1
LAMP 2
BALLAST
BLUE
BLUE
BLACK
WHITE
RED
2-17
LAMP 2
LAMP 1
LAMP 3
BALLAST
BLACK
WHITE
RED
RED
BLUE
BLUE
YELLOW
/ BLACK
YELLOW
3-5
BALLAST
RED
RED
BLUE
BLUE
BLACK
WHITE
YELLOW
YELLOW
/ BLACK
LAMP 3
LAMP 4
LAMP 1
LAMP 2
4-3
LAMP 2
LAMP 1
LAMP 3
BALLAST
RED
RED
BLUE
BLUE
BLUE
RED
BLACK
WHITE
LAMP 5
LAMP 4
LAMP 6
YELLOW
/ BLACK
YELLOW
6-1
Drawing # Overall (L) Width (W) Height (H) Mounting (M)
D2 9.50” 2.36” 1.70” 8.90”
D3 11.65” 3.15” 1.85” 11.00”
D4 14.45” 3.23” 2.20” 13.75”
Case Dimensions Case Diagram
W
H
L
M
Wiring Diagrams
BALLAST
RED
RED
BLUE
BLUE
BLACK
WHITE
YELLOW
YELLOW
/ BLACK
LAMP 2
LAMP 1
2-19
LAMP 3
LAMP 4
LAMP 1
LAMP 2
BALLAST
RED
RED
BLUE
BLUE
BLACK
WHITE
YELLOW
/ BLACK
YELLOW
4-2
BALLAST
RED
RED
BLUE
BLUE
BLUE
BLACK
WHITE
YELLOW
/ BLACK
YELLOW
RED
LAMP 4
LAMP 5
LAMP 3
LAMP 2
LAMP 1
5-1
BALLAST
RED
RED
BLUE
BLUE
BLACK
WHITE
YELLOW
YELLOW
/ BLACK
LAMP
1-17
TOC
211
ELECTRONIC SIGN BALLASTS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
ELECTRONIC SIGN BALLASTS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
ESB/0216/12 ASB-0412-12-E ESB216-12 -
ESB/0432/14 ASB-1232-24-E ESB432-14 -
ESB/0848/46 ASB-2048-46-E ESB848-46 EBO-6-8-48
ESB/1040/14 - ESB1040-14 EBO-4-10-40
HALCO ADVANCE UNIVERSAL/
MAGNETEK HOWARD
Cross Reference Guide and
Lamp Compatibility Specications
ESB/0216/12
57114
Lamp Type
# of Lamps Lamp Footage
Min Max Min Max
T12/HO 1 2 2' 16'
T8/HO 1 2 2' 12'
ESB/0432/14
57116
Lamp Type
# of Lamps Lamp Footage
Min Max Min Max
T12/HO 1 4 4' 32'
T8/HO 1 4 4' 24'
ESB/0848/46
57120
Lamp Type
# of Lamps Lamp Footage
Min Max Min Max
T12/HO 4 6 8' 48'
T8/HO 4 6 16' 36'
ESB/1040/14
57118
Lamp Type
# of Lamps Lamp Footage
Min Max Min Max
T12HO 1 4 10' 40'
T8HO 1 4 8' 32'
TOC
COMPACT FLUORESCENT BALLASTS
How to Read a Table
PL Single Tube Ballasts
PL Double Tube Ballasts
PL Triple Tube Ballasts
PLL High Lumen Ballasts
Cross Reference Guide
Specications
Lamp Compatibility Specications
214
215
216
218
220
223
223
224
CONTENTS
®
main
TOC
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
PL5S/E/2G7
15 PS 120 52102 EP2CF13PS/MV/DC/K 0.06 8 0.98 1.10 <10 0°F 1-9 L 5.00” 4.63” 2.40” 1.00”
5 PS 277 52102 EP2CF13PS/MV/DC/K 0.03 9 0.89 1.10 <15 0°F 1-9 L 5.00” 4.63” 2.40” 1.00”
25 PS 120 52102 EP2CF13PS/MV/DC/K 0.11 14 0.99 1.05 <10 0°F 2-6 L 5.00” 4.63” 2.40” 1.00”
5 PS 277 52102 EP2CF13PS/MV/DC/K 0.05 14 0.99 1.05 <10 0°F 2-6 L 5.00” 4.63” 2.40” 1.00”
HOW TO READ A COMPACT FLUORESCENT
BALLAST TABLE
BALLAST
FACTOR
Ratio of the lamp’s lumen
output on the specied
ballast to the lamp’s lumen
output when operated by a
reference ballast.
WIRING
DIAGRAM
References the wiring
diagram to use.
INPUT
POWER
Total power
input to the
ballast which
includes lamp
watts and
ballast losses.
PRODUCT CODE
Abbreviated product description
can also be used for ordering.
INPUT
VOLTS
Voltage required
from a power
supply for
proper ballast
operation.
THD%
Indicates
percentage of
Total Harmonic
Distortion.
POWER
FACTOR
Watts to volt
amps ratio,
which measures
efciency of a
ballast’s power
usage.
LINE
CURRENT
The current that
results when the
line voltage is
applied to a load. MIN STARTING
TEMP.
References minimum
ambient temperature that
the ballast will reliably
start a lamp.
PRODUCT
NUMBER
Use this number when
placing an order.
LAMP TYPE
Indicates the type
of lamp that the
ballast will operate.
CASE
DIMENSIONS
Species ballast
overall length,
mounting length,
width, and height.
CASE
References the
ballast’s case shape.
TOC
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
PL5S/E/2G7
15 PS 120 52102 EP2CF13PS/MV/DC/K 0.06 8 0.98 1.10 <10 0°F 1-9 L 5.00” 4.63” 2.40” 1.00”
5 PS 277 52102 EP2CF13PS/MV/DC/K 0.03 9 0.89 1.10 <15 0°F 1-9 L 5.00” 4.63” 2.40” 1.00”
25 PS 120 52102 EP2CF13PS/MV/DC/K 0.11 14 0.99 1.05 <10 0°F 2-6 L 5.00” 4.63” 2.40” 1.00”
5 PS 277 52102 EP2CF13PS/MV/DC/K 0.05 14 0.99 1.05 <10 0°F 2-6 L 5.00” 4.63” 2.40” 1.00”
PL7S/E/2G7
17 PS 120 52102 EP2CF13PS/MV/DC/K 0.08 11 0.98 1.07 <10 0°F 1-9 L 5.00” 4.63” 2.40” 1.00”
7 PS 277 52102 EP2CF13PS/MV/DC/K 0.04 11 0.91 1.07 <15 0°F 1-9 L 5.00” 4.63” 2.40” 1.00”
27 PS 120 52102 EP2CF13PS/MV/DC/K 0.14 20 0.99 1.03 <10 0°F 2-6 L 5.00” 4.63” 2.40” 1.00”
7 PS 277 52102 EP2CF13PS/MV/DC/K 0.06 16 0.97 1.03 <12 0°F 2-6 L 5.00” 4.63” 2.40” 1.00”
PL9S/E/2G7
19 PS 120 52102 EP2CF13PS/MV/DC/K 0.10 12 0.99 1.05 <10 0°F 1-9 L 5.00” 4.63” 2.40” 1.00”
9 PS 277 52102 EP2CF13PS/MV/DC/K 0.05 13 0.94 1.05 <15 0°F 1-9 L 5.00” 4.63” 2.40” 1.00”
2
9 PS 120 52102 EP2CF13PS/MV/DC/K 0.18 22 0.99 1.02 <10 0°F 2-6 L 5.00” 4.63” 2.40” 1.00”
9 PS 277 52102 EP2CF13PS/MV/DC/K 0.08 21 0.97 1.02 <12 0°F 2-6 L 5.00” 4.63” 2.40” 1.00”
PL Single Tube
Wiring Diagrams
Case Diagram
H
WL
M
L
BLACK
WHITE LAMP 2
GREEN
BALLAST
LAMP 1
BLUE
YEL.
RED
BLUE
YEL.
RED
2-6
BLACK
WHITE
LAMP
GREEN
BALLAST
BLUE
YEL.
RED
RED
YEL.
BLUE
1-9
215
CompaCt FluoresCent Ballasts
TOC
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
H
W
M
L
M
K
PL13D/E/G24q
1
13 RS 120 50104 E114RS/120 0.22 14 0.53 0.95 <130 0°F 1-5 K 5.90” 5.60” 0.91” 0.76”
13 PS 120 52102 EP2CF13PS/MV/DC/K 0.16 16 0.96 1.00 <10 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
13 PS 277 52102 EP2CF13PS/MV/DC/K 0.07 16 0.96 1.00 <10 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
13 RS 120 52200 E1CF13RS/120/GU24 0.22 14 0.54 1.02 <150 0°F - C 2.32” 1.54” 0.90” 1.97”
2
13 PS 120 52102 EP2CF13PS/MV/DC/K 0.27 29 0.99 1.00 <10 0°F 2-6 L 5.00” 4.63” 2.41” 1.00”
13 PS 277 52102 EP2CF13PS/MV/DC/K 0.12 29 0.99 1.00 <10 0°F 2-6 L 5.00” 4.63” 2.41” 1.00”
PL18D/E/G24q
1
18 PS 120 52102 EP2CF13PS/MV/DC/K 0.17 20 0.99 1.00 <12 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
18 PS 277 52102 EP2CF13PS/MV/DC/K 0.07 20 0.99 1.00 <12 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
18 PS 120 52104 EP2CF18PS/MV/DC/K 0.16 19 0.97 1.00 <10 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
18 PS 277 52104 EP2CF18PS/MV/DC/K 0.07 19 0.97 1.00 <10 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
2
18 PS 120 52104 EP2CF18PS/MV/DC/K 0.30 35 0.99 0.95 <10 0°F 2-6 L 5.00” 4.63” 2.41” 1.00”
18 PS 277 52104 EP2CF18PS/MV/DC/K 0.13 35 0.99 0.95 <10 0°F 2-6 L 5.00” 4.63” 2.41” 1.00”
PL Double Tube
Wiring Diagrams
Case Diagrams
H
WL
M
L
M
H
D
L
C
BALLAST
BLACK
WHITE
LINE
LAMP
RED
RED
BLUE
BLUE
1-5
BLACK
WHITE
LAMP 2
GREEN
BALLAST
LAMP 1
BLUE
YEL.
RED
BLUE
YEL.
RED
2-6
BLACK
WHITE
LAMP
GREEN
BALLAST
BLUE
YEL.
RED
RED
YEL.
BLUE
1-9
COMPACT FLUORESCENT BALLASTS
216 TOC
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
PL26D/E/G24q
1
26 PS 120 52104 EP2CF18PS/MV/DC/K 0.24 28 0.99 1.00 <12 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
26 PS 277 52104 EP2CF18PS/MV/DC/K 0.10 28 0.99 1.00 <12 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
26 PS 120 52106 EP2CF26PS/MV/DC/K 0.24 27 0.98 1.00 <10 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
26 PS 277 52106 EP2CF26PS/MV/DC/K 0.11 27 0.98 1.00 <10 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
26 PS 120 52108 EP2CF42PS/MV/DC/K 0.27 32 0.99 1.00 <10 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
26 PS 277 52108 EP2CF42PS/MV/DC/K 0.13 32 0.95 1.00 <12 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
26 RS 120 52202 E1CF26RS/120/GU24 0.32 22 0.57 0.80 <150 0°F - C
2.32”
0.95” 1.54” 1.97”
2
26 PS 120 52106 EP2CF26PS/MV/DC/K 0.45 51 0.99 1.00 <10 0°F 2-6 L 5.00” 4.63” 2.41” 1.00”
26 PS 277 52106 EP2CF26PS/MV/DC/K 0.19 51 0.99 1.00 <10 0°F 2-6 L 5.00” 4.63” 2.41” 1.00”
26 PS 120 52108 EP2CF42PS/MV/DC/K 0.45 54 0.99 0.90 <10 0°F 2-6 L 5.00” 4.63” 3.00” 1.38”
26 PS 277 52108 EP2CF42PS/MV/DC/K 0.21 54 0.97 0.90 <12 0°F 2-6 L 5.00” 4.63” 3.00” 1.38”
PL Double Tube
Wiring Diagrams
Case Diagrams
BLACK
WHITE LAMP 2
GREEN
BALLAST
LAMP 1
BLUE
YEL.
RED
BLUE
YEL.
RED
2-6
BLACK
WHITE
LAMP
GREEN
BALLAST
BLUE
YEL.
RED
RED
YEL.
BLUE
1-9
H
WL
M
L
M
H
D
L
C
217
CompaCt FluoresCent Ballasts
TOC
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
PL Triple Tube
PL18T/E/GX24q
1
18 PS 120 52102 EP2CF13PS/MV/DC/K
0.17 17 0.99 1.00 <12 0°F 1-9 L
5.00” 4.63” 2.41” 1.00”
18 PS 277 52102 EP2CF13PS/MV/DC/K
0.07 17 0.99 1.00 <12 0°F 1-9 L
5.00” 4.63” 2.41” 1.00”
18 PS 120 52104 EP2CF18PS/MV/DC/K
0.17 20 0.97 1.05 <10 0°F 1-9 L
5.00” 4.63” 2.41” 1.00”
18 PS 277 52104 EP2CF18PS/MV/DC/K
0.08 20 0.97 1.05 <10 0°F 1-9 L
5.00” 4.63” 2.41” 1.00”
2
18 PS 120 52104 EP2CF18PS/MV/DC/K
0.33 39 0.99 1.00 <10 0°F 2-6 L
5.00” 4.63” 2.41” 1.00”
18 PS 277 52104 EP2CF18PS/MV/DC/K
0.14 39 0.99 1.00 <10 0°F 2-6 L
5.00” 4.63” 2.41” 1.00”
PL26T/E/GX24q
1
26 PS 120 52104 EP2CF18PS/MV/DC/K
0.24 28 0.99 1.00 < 12 0°F 1-9 L
5.00” 4.63” 2.41” 1.00”
26 PS 277 52104 EP2CF18PS/MV/DC/K
0.10 28 0.99 1.00 <12 0°F 1-9 L
5.00” 4.63” 2.41” 1.00”
26 PS 120 52106 EP2CF26PS/MV/DC/K
0.23 29 0.98 1.00 <10 0°F 1-9 L
5.00” 4.63” 2.41” 1.00”
26 PS 277 52106 EP2CF26PS/MV/DC/K
0.10 29 0.98 1.00 <10 0°F 1-9 L
5.00” 4.63” 2.41” 1.00”
26 PS 120 52108 EP2CF42PS/MV/DC/K
0.27 32 0.99 1.00 <10 0°F 1-9 L
5.00” 4.63” 3.00” 1.38”
26 PS 277 52108 EP2CF42PS/MV/DC/K
0.13 32 0.95 1.00 <12 0°F 1-9 L
5.00” 4.63” 3.00” 1.38”
26 RS 120 52202 E1CF26RS/120/GU24
0.32 22 0.57 0.80 <150 0°F - C
2.32”
0.95” 1.54” 1.97”
2
26 PS 120 52106 EP2CF26PS/MV/DC/K
0.45 54 0.99 1.00 <10 0°F 2-6 L
5.00” 4.63” 2.41” 1.00”
26 PS 277 52106 EP2CF26PS/MV/DC/K
0.19 54 0.99 1.00 <10 0°F 2-6 L
5.00” 4.63” 2.41” 1.00”
26 PS 120 52108 EP2CF42PS/MV/DC/K
0.45 54 0.99 0.90 <10 0°F 2-6 L
5.00” 4.63” 3.00” 1.38”
26 PS 277 52108 EP2CF42PS/MV/DC/K
0.21 54 0.97 0.90 <12 0°F 2-6 L
5.00” 4.63” 3.00” 1.38”
Wiring Diagrams
Case Diagrams
BLACK
WHITE LAMP 2
GREEN
BALLAST
LAMP 1
BLUE
YEL.
RED
BLUE
YEL.
RED
2-6
BLACK
WHITE
LAMP
GREEN
BALLAST
BLUE
YEL.
RED
RED
YEL.
BLUE
1-9
H
WL
M
L
M
H
D
L
C
CompaCt FluoresCent Ballasts
218 TOC
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
PL Triple Tube
PL32T/E/GX24q
1
32 PS 120 52106 EP2CF26PS/MV/DC/K 0.26 36 0.98 0.98 <10 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
32 PS 277 52106 EP2CF26PS/MV/DC/K 0.13 36 0.98 0.98 <10 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
32 PS 120 52108 EP2CF42PS/MV/DC/K 0.35 42 0.99 0.96 <10 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
32 PS 277 52108 EP2CF42PS/MV/DC/K 0.13 42 0.96 0.96 <12 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
2
32 PS 120 52108 EP2CF42PS/MV/DC/K 0.53 63 0.99 0.95 <10 0°F 2-6 L 5.00” 4.63” 3.00” 1.38”
32 PS 277 52108 EP2CF42PS/MV/DC/K 0.23 63 0.98 0.95 <12 0°F 2-6 L 5.00” 4.63” 3.00” 1.38”
PL42T/E/GX24q
1
42 PS 120 52106 EP2CF26PS/MV/DC/K 0.38 46 0.98 0.98 <10 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
42 PS 277 52106 EP2CF26PS/MV/DC/K 0.17 46 0.98 0.98 <10 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
42 PS 120 52108 EP2CF42PS/MV/DC/K 0.40 47 0.99 1.00 <10 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
42 PS 277 52108 EP2CF42PS/MV/DC/K 0.18 47 0.96 1.00 <10 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
2
42 PS 120 52108 EP2CF42PS/MV/DC/K 0.77 94 0.99 1.00 <10 0°F 2-6 L 5.00” 4.63” 3.00” 1.38”
42 PS 277 52108 EP2CF42PS/MV/DC/K 0.38 93 0.98 1.00 <10 0°F 2-6 L 5.00” 4.63” 3.00” 1.38”
PL57T/E/GX24q
1
57 PS 120 52106 EP2CF26PS/MV/DC/K 0.43 56 0.99 0.85 <10 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
57 PS 277 52106 EP2CF26PS/MV/DC/K 0.19 56 0.99 0.85 <10 0°F 1-9 L 5.00” 4.63” 2.41” 1.00”
57 PS 120 52108 EP2CF42PS/MV/DC/K 0.49 58 0.99 1.00 <10 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
57 PS 277 52108 EP2CF42PS/MV/DC/K 0.22 58 0.97 1.00 <12 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
Wiring Diagrams
Case Diagram
BLACK
WHITE LAMP 2
GREEN
BALLAST
LAMP 1
BLUE
YEL.
RED
BLUE
YEL.
RED
2-6
BLACK
WHITE
LAMP
GREEN
BALLAST
BLUE
YEL.
RED
RED
YEL.
BLUE
1-9
H
WL
M
L
219
CompaCt FluoresCent Ballasts
TOC
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
PLL18/2G11
2
18 PS 120 52106 EP2CF26PS/MV/DC/K 0.31 35 0.99 0.92 <10 0°F 2-6 L 5.00” 4.63” 2.41” 1.00”
18 PS 277 52106 EP2CF26PS/MV/DC/K 0.14 35 0.99 0.92 <10 0°F 2-6 L 5.00” 4.63” 2.41” 1.00”
PLL24/2G11
1
24 PS 120 50142 EP239HO/PS/MV 0.24 29 0.98 1.12 <20 0°F 1-9 J 16.90” 16.00” 1.20” 1.00”
24 PS 277 50142 EP239HO/PS/MV 0.12 29 0.98 1.12 <20 0°F 1-9 J 16.90” 16.00” 1.20” 1.00”
24 PS 120 52108 EP2CF42PS/MV/DC/K 0.22 27 0.99 1.00 <10 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
24 PS 277 52108 EP2CF42PS/MV/DC/K 0.11 28 0.92 1.00 <15 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
2
24 PS 120 50142 EP239HO/PS/MV 0.46 54 0.98 1.10 <10 0°F 2-6 J 16.90” 16.00” 1.20” 1.00”
24 PS 277 50142 EP239HO/PS/MV 0.20 54 0.98 1.10 <10 0°F 2-6 J 16.90” 16.00” 1.20” 1.00”
24 PS 120 52106 EP2CF26PS/MV/DC/K 0.43 48 0.99 0.93 <10 0°F 2-6 L 5.00” 4.63” 2.41” 1.00”
24 PS 277 52106 EP2CF26PS/MV/DC/K 0.18 48 0.99 0.93 <10 0°F 2-6 L 5.00” 4.63” 2.41” 1.00”
24 PS 120 52108 EP2CF42PS/MV/DC/K 0.45 54 0.99 1.00 <10 0°F 2-6 L 5.00” 4.63” 3.00” 1.38”
24 PS 277 52108 EP2CF42PS/MV/DC/K 0.20 54 0.97 1.00 <10 0°F 2-6 L 5.00” 4.63” 3.00” 1.38”
PLL High Lumen
Wiring Diagrams
Case Diagrams
H
W
M
L
J
BLACK
WHITE LAMP 2
GREEN
BALLAST
LAMP 1
BLUE
YEL.
RED
BLUE
YEL.
RED
2-6
BLACK
WHITE
LAMP
GREEN
BALLAST
BLUE
YEL.
RED
RED
YEL.
BLUE
1-9
H
WL
M
L
CompaCt FluoresCent Ballasts
220 TOC
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
PLL36/2G11
1
36 PS 120 50142 EP239HO/PS/MV 0.30 36 0.98 0.96 <15 0°F 1-9 J 16.90” 16.00” 1.20” 1.00”
36 PS 277 50142 EP239HO/PS/MV 0.20 36 0.98 0.96 <15 0°F 1-9 J 16.90” 16.00” 1.20” 1.00”
36 PS 120 52108 EP2CF42PS/MV/DC/K 0.31 37 0.99 0.88 <10 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
36 PS 277 52108 EP2CF42PS/MV/DC/K 0.14 37 0.95 0.88 <12 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
2
36 PS 120 50142 EP239HO/PS/MV 0.59 69 0.94 0.94 <10 0°F 2-6 J 16.90” 16.00” 1.20” 1.00”
36 PS 277 50142 EP239HO/PS/MV 0.25 69 0.98 0.94 <10 0°F 2-6 J 16.90” 16.00” 1.20” 1.00”
36 PS 120 52108 EP2CF42PS/MV/DC/K 0.55 66 0.99 0.80 <10 0°F 2-6 L 5.00” 4.63” 3.00” 1.38”
36 PS 277 52108 EP2CF42PS/MV/DC/K 0.24 65 0.98 0.80 <10 0°F 2-6 L 5.00” 4.63” 3.00” 1.38”
H
W
M
L
J
Case Diagrams
Wiring Diagrams
PLL High Lumen
BLACK
WHITE LAMP 2
GREEN
BALLAST
LAMP 1
BLUE
YEL.
RED
BLUE
YEL.
RED
2-6
BLACK
WHITE
LAMP
GREEN
BALLAST
BLUE
YEL.
RED
RED
YEL.
BLUE
1-9
H
WL
M
L
221
CompaCt FluoresCent Ballasts
TOC
Lamp Type
Input
Volts
Product
Number Product Code
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
Ballast
Factor THD %
Min.
Start
Temp
Wire
Diag. Case
Case Dimensions
Qty. Watts Start
Type Length Mounting Width Height
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
PLL High Lumen
PLL40/2G11
1
40 PS 120 50142 EP239HO/PS/MV 0.42 50 0.98 1.10 <10 0°F 1-9 J 16.90” 16.00” 1.20” 1.00”
40 PS 277 50142 EP239HO/PS/MV 0.19 50 0.98 1.10 <10 0°F 1-9 J 16.90” 16.00” 1.20” 1.00”
40 PS 120 52108 EP2CF42PS/MV/DC/K 0.37 45 0.99 1.00 <10 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
40 PS 277 52108 EP2CF42PS/MV/DC/K 0.17 45 0.96 1.00 <12 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
2
40 PS 120 52108 EP2CF42PS/MV/DC/K 0.69 82 0.99 0.95 <10 0°F 2-6 L 5.00” 4.63” 3.00” 1.38”
40 PS 277 52108 EP2CF42PS/MV/DC/K 0.30 82 0.98 0.95 <10 0°F 2-6 L 5.00” 4.63” 3.00” 1.38”
3
40 IS 120 50124 EP432IS/120/SL 0.82 107 0.99 0.88 <10 0°F 3-4 F
9.50” 8.82” 1.70” 1.15”
PLL55/2G11
1
55 PS 120 50144 EP254HO/PS/MV 0.49 58 0.96 0.92 <15 0°F 1-9 J 16.90” 16.00” 1.20” 1.00”
55 PS 277 50144 EP254HO/PS/MV 0.22 58 0.96 0.92 <15 0°F 1-9 J 16.90” 16.00” 1.20” 1.00”
55 PS 120 52108 EP2CF42PS/MV/DC/K 0.37 44 0.99 0.70 <10 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
55 PS 277 52108 EP2CF42PS/MV/DC/K 0.17 44 0.96 0.70 <12 0°F 1-9 L 5.00” 4.63” 3.00” 1.38”
2
55 PS 120 50144 EP254HO/PS/MV 0.94 112 0.98 0.90 <10 0°F 2-6 J 16.90” 16.00” 1.20” 1.00”
55 PS 277 50144 EP254HO/PS/MV 0.41 112 0.98 0.90 <10 0°F 2-6 J 16.90” 16.00” 1.20” 1.00”
BALLAST
RED
RED
YEL
BLACK
WHITE
LINE
BLUE
BLUE
YEL
LAMP 3
LAMP 2
LAMP 1
3-4
Wiring Diagrams
Case Diagrams
H
W
L
M
F
BLACK
WHITE
LAMP 2
GREEN
BALLAST
LAMP 1
BLUE
YEL.
RED
BLUE
YEL.
RED
2-6
BLACK
WHITE
LAMP
GREEN
BALLAST
BLUE
YEL.
RED
RED
YEL.
BLUE
1-9
H
WL
M
L
H
W
M
L
J
COMPACT FLUORESCENT BALLASTS
222 TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
EP2CF13PS/MV/DC/K ICF-2S13-H1-LD C213UNV EP2/13CF/MV/K
EP2CF18PS/MV/DC/K ICF-2S18-H1-LD C218UNV EP2/18CF/MV/K
EP2CF26PS/MV/DC/K ICF-2S26-H1-LD C2642UNV EP2/26CF/MV/K2
EP2CF42PS/MV/DC/K ICF-2S42-M2-LD C242UNV EP2/42CF/MV/K2
HALCO ADVANCE UNIVERSAL/
MAGNETEK HOWARD
Cross Reference Guide and Specications
SPECIFICATIONS
Ballast shall have a Lamp Current Crest Factor of <1.7 in accordance with ANSI C82.1.
Ballast shall withstand line voltage transients and surges as specied in ANSI standard
C62.41-1991.
Ballast shall have an Underwriters Laboratories certication for operation in the US and
either an Underwriters Laboratories or Canadian Standards Association certication for
operation in Canada.
Ballast shall comply with the EMI and RFI limits of the code of Federal Regulations, Title 47,
Part 18C for Non-Consumer equipment.
Ballast shall operate in the range of 50-60Hz input frequency.
Ballast shall operate at a maximum of 18 feet remote mounting distance for primary lamp.
For energy saving reduced wattages lamps, remote mounting distances will be shorter.
Ballast shall operate at a frequency of 20-40 kHz.
Ballast shall contain potting compound in order to protect from moisture, dissipate heat and
provide stability.
All ProFormance ballasts shall have a power factor of 0.98 or better on the primary lamp
conguration.
Ballast shall be sound rated Class A.
Ballast shall have a minimum starting temperature of 0˚F standard lamps and 60°F on
Energy Saving lamps.
Ballast shall tolerate sustained variations of +/-10% of supply voltage with
no damage to the ballast.
Ballast shall not contain PCBs.
Manufacturer shall provide written warranty against defects in material or workmanship
for 5 years from date of manufacture.
COMPACT FLUORESCENT BALLASTS
223
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Lamp Compatibility Specications
COMPACT FLUORESCENT BALLASTS
224
E1CF13RS/120/GU24
52200
Lamp Type # of
Lamps
PL13D/E/G24q 1
PL13T/E/GX24q 1
EP2CF13PS/MV/DC/K
52102
Lamp Type # of
Lamps
PL13D/E/G24q 1, 2
PL13T/E/GX24q 1, 2
PL18T/E/GX24q 1, 2
PL10/2D/GR10q 1, 2
PL16/2D/GR10q 1, 2
F14T5 1, 2
F13T5 1, 2
PL5/S/E/2G7 1, 2
PL7/S/E/2G7 1, 2
PL9/S/E/2G7 1, 2
E1CF26RS/120/GU24
52202
Lamp Type # of
Lamps
PL26D/E/G24q 1
PL26T/E/GX24q 1
EP2CF18PS/MV/DC/K
52104
Lamp Type # of
Lamps
PL18D/E/G24q 1, 2
PL18T/E/GX24q 1, 2
PL26D/E/G24q 1, 2
PL16/2D/GR10q 1, 2
PL21/2D/GR10q 1, 2
PL28/2D/GR10q 1
EP2CF26PS/MV/DC/K
52106
Lamp Type # of
Lamps
PL26D/E/G24q 1, 2
PL57D/E/G24q 1
PL26T/E/GX24q 1, 2
PL32T/E/GX24q 1
PL42T/E/GX24q 1
PL57T/E/GX24q 1
PLL18/2G11 2
PLL24/2G11 1, 2
PLL36/2G11 1
PLL40/2G11 1
PL21/2D/GR10q 2
PL28/2D/GR10q 1
FC40T5 1
FC22T5 1
FC16T9 1
EP2CF42PS/MV/DC/K
52108
Lamp Type # of
Lamps
PL42T/E/GX24q 1, 2
PL32T/E/GX24q 1, 2
PL26D/E/G24q 1, 2
PL26T/E/GX24q 1, 2
PLL39/2G11 1, 2
PLL40/2G11 1, 2
PLL36/2G11 1, 2
PLL24/2G11 1, 2
PL57T/E/GX24q 1
PL28/2D/GR10q 2
PL28/2D/GR10q 1
FC22T5 + FC40T5 2
FC22T5 2
FC22T5 1
FC40T5 2
FC40T5 1
TOC
ELECTRONIC HID BALLASTS
How to Read a Table
Ceramic Discharge Metal Halide Ballasts
Case Dimensions and Wiring Diagrams
Cross Reference Guide
Specications
228
229
229
230
231
CONTENTS
®
main
TOC
No. of
Lamps
Input
Volts
Product
Number Product Code
Input
Power
(Watts)
Nominal
Line
Amps
Max
Ignition
Pulse
Power
Factor
Ballast
Factor Fig
Ballast Dimensions Total Ballast
Case Weight
(lbs)
Wiring
Diagram
Overall
Length Width Height
20 Watt CDM Lamp, ANSI Code C156 or M156
1120 55504 C156/20E/MV/BE 23 0.19 3.5 kV 0.96 1.00 N1 3.69” 2.59” 1.18” 0.57 1-22
277 0.09
1120 55502 C156/20E/MV/SE 23 0.19 3.5 kV 0.96 1.00 E1 4.43” 2.59” 1.18” 0.57 1-22
277 0.09
HOW TO READ AN ELECTRONIC HID
BALLAST TABLE
INPUT
POWER
Total power
input to the
ballast which
includes lamp
watts and
ballast losses.
LAMP TYPE
Indicates the type
of lamp that the
ballast will operate.
PRODUCT
NUMBER
Use this number when
placing an order.
POWER
FACTOR
Watts to volt amps
ratio, which measures
efciency of a ballast’s
power usage.
NOMINAL
LINE AMPS
Ballast’s rated line
current. Typically
the middle of an
acceptable range.
TOTAL BALLAST
CASE WEIGHT
Total weight of ballast
to include case.
MAX
IGNITION
PULSE
Maximum voltage
pulse provided
by the ignitor to
initiate an electrical
discharge in a gas
lled tube.
PRODUCT
CODE
Abbreviated product
description can also be
used for ordering.
INPUT
VOLTS
Voltage required
from a power
supply for
proper ballast
operation.
NUMBER
OF LAMPS
Indicates the number
of lamps the ballast
will operate.
BALLAST
FACTOR
Ratio of the lamp’s
lumen output
on the specied
ballast to the lamp’s
lumen output when
operated by a
reference ballast.
WIRING
DIAGRAM
References the
wiring diagram
to use.
BALLAST
DIMENSIONS
Species ballast
overall length,
width, and height.
FIGURE
Representation
of the ballast.
TOC
229
ELECTRONIC HID BALLASTS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
No. of
Lamps
Input
Volts
Product
Number Product Code
Input
Power
(Watts)
Nominal
Line
Amps
Max
Ignition
Pulse
Power
Factor
Ballast
Factor Fig
Ballast Dimensions Total Ballast
Case Weight
(lbs)
Wiring
Diagram
Overall
Length Width Height
20 Watt CDM Lamp, ANSI Code C156 or M156
1120 55504 C156/20E/MV/BE 23 0.19 3.5 kV 0.96 1.00 N1 3.69” 2.59” 1.18” 0.57 1-22
277 0.09
1120 55502 C156/20E/MV/SE 23 0.19 3.5 kV 0.96 1.00 E1 4.43” 2.59” 1.18” 0.57 1-22
277 0.09
39 Watt CDM Lamp, ANSI Code C130 or M130
1120 55508 C130/35E/MV/BE 43 0.32 3.8 kV 0.96 1.00 N1 3.69” 2.59” 1.18” 0.57 1-22
277 0.14
1120 55506 C130/35E/MV/SE 43 0.32 3.8 kV 0.96 1.00 E1 4.43” 2.59” 1.18” 0.57 1-22
277 0.14
70 Watt CDM Lamp, ANSI Code C143 or M143; C139 or M139; C98 or M98
1120 55512 C139/70E/MV/BE 77 0.65 4.0 kV 0.98 1.00 N2 4.15” 3.10” 1.16” 1.06 1-22
277 0.29
1120 55510 C139/70E/MV/SE 77 0.65 4.0 kV 0.98 1.00 E2 4.83” 3.10” 1.15” 1.06 1-22
277 0.29
Wiring Diagram
Ballast Dimensions
BLACK
WHITE
GREEN BROWN
ORANGE LAMP
BALLAST
1-22
E
L
H
W
M1
N
L
W
H
M1
Drawing #
Overall
Length
Case
Length (L)
Case
Width (W)
Case
Height(H)
Mounting
Length (M1)
Mounting
Length (M2)
E1 4.43” 3.69” 2.59” 1.18” 4.13” 1.89"
E2 4.83” 4.15” 3.10” 1.15” 4.52” 2.45”
N1 3.69” 3.69” 2.59” 1.18” 2.00” 0.26"
N2 4.15" 4.15" 3.10" 1.16" 2.00" 0.26"
Ceramic Discharge Metal Halide
TOC
ElEctronic HiD Ballasts
230 Halco Lighting Technologies | 800.677.3334 | halcolighting.com
M102/150HX/4T/K 71A5492-001D M150MLTLC3M500K M0150-71C-512-K
M110/50HX/4T/K 71A5191-001D M50MLTLC3M500K M0050-23C-511-K
M141/1000CWA/4T/K 71A6593-001 P1000MLTAC5M500K M1000-71C-612-K
M141/1000CWA/5T/K 71A6552-001D P1000ML5AC5M500K M1000-81C-611-K
M149/750CWA/4T/K 71A64F2-001D P750MLTAC5M500K M0750-71C-612-K
M149/750CWA/5T/K 71A6452-001D P750ML5AC5M500K M0750-81C-612-K
M131/350CWA/4T/K 71A5993-001D P350MLTAC4M500K M0350-71C-6E4-K
M131/350CWA/5T/K 71A5953-001D P350ML5AC4M500K -
M132/320CWA/4T/K 71A5892-001D P320MLTAC4O500K M0320-71C-6E4-K
M132/320CWA/5T/K 71A5852-001D P320ML5AC4L500K -
M135/400CWA/4T/K 71A6092-001D P400MLTAC4L500K M0400-71C-6E3-K
M135/400CWA/5T/K - P400ML5AC4M500K -
M138/250CWA/4T/K 71A5792-001D P250MLTAC4L500K M0250-71C-611-K
M138/250CWA/5T/K - P250ML5AC4M500K -
M150/125CWA/4T/K - - -
M90/100HX/4T/K 71A5390-001D M100MLTLC3M500K M0100-71C-512-K
M98/70HX/4T/K 71A5292-001D M70MLTLC3M500K M0070-71C-511-K
HALCO ADVANCE UNIVERSAL/
MAGNETEK HOWARD
Cross Reference Guide
TOC
231
ELECTRONIC HID BALLASTS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
SPECIFICATIONS
Ballast shall be furnished with integral, color-coded leads.
Ballast shall tolerate sustained variations of +/- 10% of supply voltage with no
damage to the ballast.
Ballast shall operate in the range of 50-60Hz input frequency.
Ballast shall operate at a maximum of 6 feet remote mounting distance.
Ballast shall be microprocessor controlled.
Ballast shall have integrated thermal, transient and end-of-life protection.
Ballast shall be thermally protected to shut off when operating temperatures
reach unacceptable levels.
Ballast shall have an Underwriters Laboratories certication for operation in the US and
either an Underwriters Laboratories or Canadian Standards Association certication for
operation in Canada.
Ballast shall comply with EMI and RFI limits of the code of Federal Regulations, Title 47,
Part 18C for Non-Consumer equipment.
Ballast shall have a Lamp Current Crest Factor of <1.7.
Ballast shall provide the lamp with a low frequency square wave form to minimize visible
icker and increase lamp life.
Ballast shall be Sound Rated Class A.
Ballast input current shall have a Total Harmonic Distortion of <15%.
Ballast shall have a Power Factor greater than 90%.
Ballast shall have a lamp end-of-life detection and shut down circuit.
Ballast shall not contain PCBs.
Manufacturer shall provide written warranty against defects in material or workmanship
for 3 years from date of manufacture.
TOC
Specications
®
ELECTROMAGNETIC HID BALLASTS
How to Read a Table
Pulse Start Metal Halide Ballasts
Standard Metal Halide Ballasts
High Pressure Sodium Ballasts
Capacitor Guide
Ignitor Guide
Cross Reference Guide
Specications
234
235
239
242
245
246
247
249
CONTENTS
main
TOC
TOC
50 Watt Pulse Start MH Lamp, ANSI Code M110
120
55192
M110/50HX/4T/K HX-HPF 65
0.60
258
5
E 1.05 2.48 6 280 MH1 4.92 3.10
A
208
0.40 3 A
240
0.30 3 A
277
0.30 2 A
Input
Volts
Product
Number Product Code Circuit
Type
Input
Power
(Watts)
Max Input
Current
(Amps
)
Nom.
Open
Circuit
Volts
Fuse
Rating
(Amps)
Dimensions Capacitor
Ignitor
(IGN/)
Kit Weight (lbs)
UL Bench
Top Rise
Fig A Max B Max Mfd Volts Total
Weight
Ballast
Weight
INPUT
POWER
Total power
input to the
ballast which
includes lamp
watts and
ballast losses.
LAMP TYPE
Indicates the type
of lamp that the
ballast will operate.
PRODUCT
NUMBER
Use this number when
placing an order.
MAX INPUT
CURRENT (Amps)
For HX and R circuits, value is
the highest of starting operating
or open circuit current. For CWA
or Super CWA circuits, value is
the operating current.
CIRCUIT
TYPE
Indicates the ballast
circuit type.
KIT
WEIGHT
Total weight
of ballast to
include case.
CAPACITOR (Mfd, volts)
Species the electrical characteristics
of the capacitor.
PRODUCT
CODE
Abbreviated product
description can also be
used for ordering.
INPUT
VOLTS
Voltage required
from a power
supply for
proper ballast
operation.
FUSE RATING
Ballast’s maximum
fuse rating.
UL BENCH
TOP RISE
To facilitate UL
inspection, the
UL Bench Top
Rise Temperature
Code is shown
on the Halco Core
& Coil Ballast
label as 1029X.
BALLAST
DIMENSIONS
Indicates
ballast’s size.
NOMINAL
OPEN
CIRCUIT
VOLTS
Typically the
middle of a ballast’s
acceptable Open
Circuit Voltage range.
IGNITOR
Identies the
Halco ignitor
product code
to be used with
the ballast.
HOW TO READ AN ELECTROMAGNETIC HID
BALLAST TABLE
ELECTROMAGNETIC HID BALLASTS
235
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Input
Volts
Product
Number Product Code Circuit
Type
Input
Power
(Watts)
Max Input
Current
(Amps
)
Nom.
Open
Circuit
Volts
Fuse
Rating
(Amps)
Dimensions Capacitor
Ignitor
(IGN/)
Kit Weight (lbs)
UL Bench
Top Rise
Fig A Max B Max Mfd Volts Total
Weight
Ballast
Weight
TOC
50 Watt Pulse Start MH Lamp, ANSI Code M110
120
55192
M110/50HX/4T/K HX-HPF 65
0.60
258
5
E 1.05 2.48 6 280 MH1 4.92 3.10
A
208
0.40 3 A
240
0.30 3 A
277
0.30 2 A
70 Watt Pulse Start MH Lamp, ANSI Code M98
120
55134
M98/70HX/4T/K HX-HPF 85
1.60
252
4
E 1.47 2.90 8 280 MH1 6.75 4.50
A
208
0.90 3 A
240
0.80 3 A
277
0.70 2 A
100 Watt Pulse Start MH Lamp, ANSI Code M90
120
55136 M90/100HX/4T/K HX-HPF 120
2.40
276
8
E 1.58 2.96 12 280 MH1 6.28 4.80
A
208 1.40 6 A
240 1.20 4 A
277 1.10 4 A
125 Watt Pulse Start MH Lamp, ANSI Code M150
120
55170
M150/125CWA/4T/K Super
CWA 150
1.25
228
4
E 1.70 3.10 12 280 MH1 6.00 5.80
A
208
0.75 3 A
240
0.65 2 A
277
0.55 2 A
150 Watt Pulse Start MH Lamp, ANSI Code M102
120
55138 M102/150HX/4T/K HX-HPF 182
1.60
255
10
E 2.28 3.80 16 280 MH1 9.06 6.80
A
208 1.00 5 A
240 0.90 5 A
277 0.80 4 A
3
15/16
"
2
7/16
"
2
13/16
"
4 Holes >= 0.25"
Cleared for #10 bolts
A max
B max
3
1/2
"
Figure E
Ballast Dimensions
Pulse Start Metal Halide
ELECTROMAGNETIC HID BALLASTS
236
Input
Volts
Product
Number Product Code Circuit
Type
Input
Power
(Watts)
Max Input
Current
(Amps
)
Nom.
Open
Circuit
Volts
Fuse
Rating
(Amps)
Dimensions Capacitor
Ignitor
(IGN/)
Kit Weight (lbs)
UL Bench
Top Rise
Fig A Max B Max Mfd Volts Total
Weight
Ballast
Weight
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
Ballast Dimensions
250 Watt Pulse Start MH Lamp, ANSI Code M138 or M153
120
55160
M138/250CWA/4T/K
Super
CWA 278
2.45
274
10
I 1.85 3.78 15 400 MH2 11.79 9.80
A
208 1.40 6 A
240 1.25 6 A
277 1.10 5 A
120
55174
M138/250CWA/5T/K
Super
CWA 282
2.45
286
12
I 1.99 3.90 15 400 MH2 10.30 11.50
A
208 1.40 6 A
240 1.25 6 A
277 1.10 5 A
480 0.65 3 A
320 Watt Pulse Start MH Lamp, ANSI Code M132 or M154
120
55148 M132/320CWA/4T/K Super
CWA 361
3.10
279
10
I 2.18 4.40 21 360 MH2 12.20 11.00
B
208 1.80 6 B
240 1.55 6 B
277 1.35 5 B
120
55176 M132/320CWA/5T/K Super
CWA 355
3.10
276
12
I 2.18 4.40 21 345 MH2 11.88 11.50
C
208 1.80 8 C
240 1.55 6 C
277 1.35 5 C
480 0.78 3 C
350 Watt Pulse Start MH Lamp, ANSI Code M131
120
55150
M131/350CWA/4T/K Super
CWA 400
3.30
257
12
I 2.32 4.40 24 400 MH2 12.50 11.80
A
208
1.90 6 A
240
1.60 6 A
277
1.40 5 A
120
55172 M131/350CWA/5T/K Super
CWA 410
3.40
265
10
I 2.32 4.40 24 330 MH2 12.80 12.20
A
208 2.00 7 A
240 1.70 5 A
277 1.50 5 A
480 0.90 3 A
3
7/8
"
4 Holes >= 0.25"
Cleared for #10 bolts
4
3/8
"
4
3/4
"
A max
B max
4
1/4
"
Figure
I
Pulse Start Metal Halide
ELECTROMAGNETIC HID BALLASTS
237
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Input
Volts
Product
Number Product Code Circuit
Type
Input
Power
(Watts)
Max Input
Current
(Amps
)
Nom.
Open
Circuit
Volts
Fuse
Rating
(Amps)
Dimensions Capacitor
Ignitor
(IGN/)
Kit Weight (lbs)
UL Bench
Top Rise
Fig A Max B Max Mfd Volts Total
Weight
Ballast
Weight
TOC
3
7/8
"
4 Holes >= 0.25"
Cleared for #10 bolts
4
3/8
"
4
3/4
"
A max
B max
4
1/4
"
Figure I
Ballast Dimensions
400 Watt Pulse Start MH Lamp, ANSI Code M135 or M155
120
55162 M135/400CWA/4T/K Super
CWA 460
4.00
282
12
I 2.32 4.30 26 400 MH2 11.50 11.20
B
208 2.30 6 C
240 2.00 6 D
277 1.75 5 D
120
55178 M135/400CWA/5T/K Super
CWA 458
3.81
268
12
I 2.32 4.25 26 400 MH2 16.98 12.20
A
208 2.15 6 A
240 1.92 6 A
277 1.67 5 A
480 0.93 3 A
750 Watt Pulse Start MH Lamp, ANSI Code M149 or M181
120
55188 M149/750CWA/4T/K Super
CWA 842
7.23
370
20
O 2.62 4.80 24 480 - 20.28 17.00
A
208 4.05 10 A
240 3.64 10 A
277 3.13 8 A
120
55190 M149/750CWA/5T/K Super
CWA 810
7.20
371
20
O 2.84 4.80 24 480 - 20.28 18.80
A
208 4.10 10 A
240 3.60 10 A
277 3.13 8 A
480 1.80 6 A
A max
3
7/8
"
4
1/4
"
8 Holes >= 0.25"
Cleared for #10 bolts
4
3/8
"
6"
5
3/8
"
B max
Figure
O
Pulse Start Metal Halide
ElEctromagnEtic hid ballasts
238
Input
Volts
Product
Number Product Code Circuit
Type
Input
Power
(Watts)
Max Input
Current
(Amps
)
Nom.
Open
Circuit
Volts
Fuse
Rating
(Amps)
Dimensions Capacitor
Ignitor
(IGN/)
Kit Weight (lbs)
UL Bench
Top Rise
Fig A Max B Max Mfd Volts Total
Weight
Ballast
Weight
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
875 Watt Pulse Start MH Lamp, ANSI Code M166
120
55194 M166/875CWA/4T/K Super
CWA 930
8.10
400
20
O 3.01 4.92 22 480 - 23.39 19.40
A
208 4.70 15 A
240 4.10 10 A
277 3.60 10 A
120
55196 M166/875CWA/5T/K Super
CWA 930
8.20
400
20
O 3.01 4.92 22 480 - 22.68 19.40
A
208 4.80 12 A
240 4.30 10 A
277 3.60 10 A
480 2.10 8 A
1000 Watt Pulse Start MH Lamp, ANSI Code M141
120
55184 M141/1000CWA/4T/K Super
CWA 1090
9.20
404
20
O 3.01 5.05 24 480 - 20.24 20.10
A
208 5.30 15 A
240 4.60 10 A
277 4.00 10 A
120
55186 M141/100CWA/5T/K Super
CWA 1070
8.80
413
20
O 3.25 5.22 21.4 480 - 21.40 21.40
A
208 5.10 15 A
240 4.50 10 A
277 3.90 10 A
480 2.30 8 A
A max
3
7/8
"
4
1/4
"
8 Holes >= 0.25"
Cleared for #10 bolts
4
3/8
"
6"
5
3/8
"
B max
Figure
O
Ballast Dimensions
Pulse Start Metal Halide
ELECTROMAGNETIC HID BALLASTS
239
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Input
Volts
Product
Number Product Code Circuit
Type
Input
Power
(Watts)
Max Input
Current
(Amps
)
Nom.
Open
Circuit
Volts
Fuse
Rating
(Amps)
Dimensions Capacitor
Ignitor
(IGN/)
Kit Weight (lbs)
UL Bench
Top Rise
Fig A Max B Max Mfd Volts Total
Weight
Ballast
Weight
TOC
Standard Metal Halide
175 Watt MH Lamp, ANSI Code M57
120
55140 M57/175CWA/4T/K CWA 202
1.80
282
10
E 2.60 4.02 10 400 - 8.90 6.90
A
208 1.00 5 A
240 0.90 4 A
277 0.80 3 A
120
55142 M57/175CWA/5T/K CWA 210
1.90
302
10
E 2.44 4.10 10 400 - 8.90 6.90
A
208 1.10 5 A
240 0.90 5 A
277 0.80 3 A
480 0.50 2 A
250 Watt MH Lamp, ANSI Code M58
120
55144 M58/250CWA/4T/K CWA 295
2.60
304
10
I 1.61 3.54 15 400 - 10.20 8.00
A
208 1.50 6 A
240 1.30 5 A
277 1.15 5 A
120
55146 M58/250CWA/5T/K CWA 289
2.50
307
10
I 1.85 3.70 15 400 - 12.60 10.40
A
208 1.45 6 A
240 1.25 5 A
277 1.50 5 A
480 0.65 3 A
3
7/8
"
4 Holes >= 0.25"
Cleared for #10 bolts
4
3/8
"
4
3/4
"
A max
B max
4
1/4
"
3
15/16
"
2
7/16
"
2
13/16
"
4 Holes >= 0.25"
Cleared for #10 bolts
A max
B max
3
1/2
"
Figure
I
Figure E
Ballast Dimensions
ELECTROMAGNETIC HID BALLASTS
240
Input
Volts
Product
Number Product Code Circuit
Type
Input
Power
(Watts)
Max Input
Current
(Amps
)
Nom.
Open
Circuit
Volts
Fuse
Rating
(Amps)
Dimensions Capacitor
Ignitor
(IGN/)
Kit Weight (lbs)
UL Bench
Top Rise
Fig A Max B Max Mfd Volts Total
Weight
Ballast
Weight
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
A max
3
7/8
"
4
1/4
"
8 Holes >= 0.25"
Cleared for #10 bolts
4
3/8
"
6"
5
3/8
"
B max
3
7/8
"
4 Holes >= 0.25"
Cleared for #10 bolts
4
3/8
"
4
3/4
"
A max
B max
4
1/4
"
400 Watt MH Lamp, ANSI Code M59
120
55152 M59/400CWA/4T/K
CWA 458
4.00
300
12
I 2.16 4.30 24 360 - 13.32 11.04
B
208
2.30 8 C
240
2.00 6 C
277
1.80 6 D
120
55154 M59/400CWA/5T/K
CWA 452
4.00
300
12
I 2.32 4.34 24 400 - 14.64 11.40
B
208
2.30 8 B
240
2.00 6 C
277
1.80 6 C
480
1.00 4 C
1000 Watt MH Lamp, ANSI Code M47
120
55156 M47/1000CWA/4T/K CWA 1076
9.20
411
20
O 3.01 4.92 24 480 - 22.52 18.90
A
208 5.30 15 A
240 4.60 10 A
277 4.00 10 A
120
55158 M47/1000CWA/5T/K CWA 1087
9.20
420
20
O 3.25 5.20 24 480 - 24.06 19.90
A
208 5.30 15 A
240 4.60 10 A
277 4.00 10 A
480 2.30 6 A
Figure
O
Figure
I
Ballast Dimensions
Standard Metal Halide
electromagnetic hid Ballasts
241
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Input
Volts
Product
Number Product Code Circuit
Type
Input
Power
(Watts)
Max Input
Current
(Amps
)
Nom.
Open
Circuit
Volts
Fuse
Rating
(Amps)
Dimensions Capacitor
Ignitor
(IGN/)
Kit Weight (lbs)
UL Bench
Top Rise
Fig A Max B Max Mfd Volts Total
Weight
Ballast
Weight
TOC
1500 Watt MH Lamp, ANSI Code M48
120
55180 M48/1500CWA/4T/K
CWA 1542
13.20
430
30
O 4.49 6.85 32 525 - 32.34 28.00
B
208
7.60 25 A
240
6.70 20 A
277
5.80 15 A
120
55182 M48/1500CWA/5T/K
CWA 1550
13.00
430
44
O 4.49 6.90 32 525 - 32.34 29.00
C
208
7.50 22 C
240
6.50 20 B
277
5.70 17 B
480
3.30 10 A
Ballast Dimensions
Standard Metal Halide
A max
3
7/8
"
4
1/4
"
8 Holes >= 0.25"
Cleared for #10 bolts
4
3/8
"
6"
5
3/8
"
B max
Figure
O
ELECTROMAGNETIC HID BALLASTS
242
Input
Volts
Product
Number Product Code Circuit
Type
Input
Power
(Watts)
Max Input
Current
(Amps
)
Nom.
Open
Circuit
Volts
Fuse
Rating
(Amps)
Dimensions Capacitor
Ignitor
(IGN/)
Kit Weight (lbs)
UL Bench
Top Rise
Fig A Max B Max Mfd Volts Total
Weight
Ballast
Weight
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
35 Watt HPS Lamp, ANSI Code S76
120 55102 S76/35R/120/K *R-HPF 54 0.80 120 3 A 0.61 1.80 14 120 HPS1 1.97 1.10 A
50 Watt HPS Lamp, ANSI Code S68
120 55104 S68/50R/120/K *R-HPF 61 1.20 120 4 A 0.83 2.00 20 120 HPS1 2.40 1.70 A
70 Watt HPS Lamp, ANSI Code S62
120 55106 S62/70R/120/K *R-HPF 83 1.65 120 4 A 1.30 2.50 28 120 HPS1 3.22 2.00 A
120
55108 S62/70HX/4T/K HX-HPF 95
1.40
125
3
E 1.54 2.95 7 280 HPS1 6.79 4.60
A
208 0.80 2 A
240 0.70 2 A
277 0.60 2 A
100 Watt HPS Lamp, ANSI Code S54
120 55110 S54/100R/120/K *R-HPF 116 2.10 120 5 A 1.77 2.95 36 120 HPS1 3.63 2.50 A
120
55112 S54/100HX/4T/K HX-HPF 130
2.20
118
4
E 1.97 3.35 10 280 HPS1 8.26 6.00
A
208 1.30 3 A
240 1.10 2 A
277 1.00 2 A
150 Watt HPS Lamp, ANSI Code S55
120 55114 S55/150R/120/K *R-HPF 168 3.10 120 6 A 2.36 3.54 55 120 HPS1 5.46 3.25 A
120
55116 S55/150HX/4T/K HX-HPF 182
3.00
121
5
E 2.56 4.05 14 280 HPS1 8.73 7.40
A
208 1.70 3 A
240 1.50 3 A
277 1.30 3 A
3
15/16
"
2
7/16
"
2
13/16
"
4 Holes >= 0.25"
Cleared for #10 bolts
A max
B max
3
1/2
"
1
25/32
"
2
7/32
"
4 Holes >= 0.195"
Cleared for #6 bolts
2
3/16
"
2
5/8
"
B max
A max
Figure A Figure E
Ballast Dimensions
*Ballast operates at High Power Factor when capacitor (not included with kit) is installed. If the capacitor is omitted, ballast will operate at Normal Power Factor.
High Pressure Sodium
electromagnetic hid Ballasts
243
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Input
Volts
Product
Number Product Code Circuit
Type
Input
Power
(Watts)
Max Input
Current
(Amps
)
Nom.
Open
Circuit
Volts
Fuse
Rating
(Amps)
Dimensions Capacitor
Ignitor
(IGN/)
Kit Weight (lbs)
UL Bench
Top Rise
Fig A Max B Max Mfd Volts Total
Weight
Ballast
Weight
TOC
200 Watt HPS Lamp, ANSI Code S66
120
55118
S66/200CWA/4T/K
CWA 240
2.10
178
6
I 1.22 3.05 28 250 HPS2 9.21 7.60
A
208 1.20 4 A
240 1.10 3 A
277 0.90 3 A
250 Watt HPS Lamp, ANSI Code S50
120
55120 S50/250CWA/4T/K CWA 300
2.50
185
7
I 1.85 3.50 35 240 HPS2 12.62 9.93
A
208 1.50 4 A
240 1.30 4 A
277 1.10 3 A
120
55122 S50/250CWA/5T/K CWA 298
2.60
185
7
I 1.97 3.90 35 240 HPS2 13.60 10.70
A
208 1.50 4 A
240 1.30 4 A
277 1.10 3 A
480 0.60 2 A
400 Watt HPS Lamp, ANSI Code S51
120
55124 S51/400CWA/4T/K CWA 453
3.80
182
10
I 2.32 4.18 55 240 HPS2 14.82 12.60
A
208 2.20 7 A
240 1.90 5 A
277 1.70 5 A
120
55126 S51/400CWA/5T/K CWA 450
3.80
185
10
I 2.56 4.70 55 240 HPS2 17.37 13.70
A
208 2.20 7 A
240 1.90 5 A
277 1.60 5 A
480 0.90 3 A
3
7/8
"
4 Holes >= 0.25"
Cleared for #10 bolts
4
3/8
"
4
3/4
"
A max
B max
4
1/4
"
Figure
I
Ballast Dimensions
High Pressure Sodium
ElEctromagnEtic hid ballasts
244
Input
Volts
Product
Number Product Code Circuit
Type
Input
Power
(Watts)
Max Input
Current
(Amps
)
Nom.
Open
Circuit
Volts
Fuse
Rating
(Amps)
Dimensions Capacitor
Ignitor
(IGN/)
Kit Weight (lbs)
UL Bench
Top Rise
Fig A Max B Max Mfd Volts Total
Weight
Ballast
Weight
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
1000 Watt HPS Lamp, ANSI Code S52
120
55128 S52/1000CWA/4T/K CWA 1030
8.80
430
25
O 4.33 6.40 26 525 HPS3 30.50 26.00
A
208 5.10 15 A
240 4.40 10 A
277 3.90 10 A
120
55130 S52/1000CWA/5T/K CWA 1070
9.70
430
25
O 4.1 6.10 26 525 HPS3 32.00 26.00
A
208 5.60 15 A
240 4.90 12 A
277 4.20 10 A
480 2.40 6 A
A max
3
7/8
"
4
1/4
"
8 Holes >= 0.25"
Cleared for #10 bolts
4
3/8
"
6"
5
3/8
"
B max
Figure O
Ballast Dimensions
High Pressure Sodium
Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOC 245
Capacitor Guide
DRY FILM
55851 *CAP/MH50 M110/50HX/2T/K 6 280 35 1.38 48 1.89
55853 CAP/MH70 M98/70HX/4T/K 8 280 30 1.19 68 2.68
55855 CAP/MH100 M90/100HX/4T/K 12 280 30 1.19 78 3.08
55857 CAP/MH150 M102/150HX/4T/K 16 280 35 1.38 78 3.08
55859 CAP/MH175 M57/175CWA/4T/K 10 400 35 1.38 78 3.08
M57/175CWA/5T/K
55861 CAP/MH250 M58/250CWA/4T/K 15 400 40 1.58 78 3.08
M58/250CWA/5T/K
55871 CAP/MH250PS M138/250CWA/4T/K 18.5 330 35 1.38 78 3.08
55863 CAP/MH320PS M132/320CWA/4T/K 21 345 40 1.58 79 3.08
M132/320CWA/5T/K
55865 CAP/MH350PS M131/350CWA/4T/K 22.5 345 40 1.58 78 3.08
M131/350CWA/5T/K
55873 CAP/MH400PS M135/400CWA/4T/K 26 330 40 1.58 93 3.66
M135/400CWA/5T/K
55868 CAP/MH400/DRY M59/400/CWA/4T/K 24 400 45 1.77 93 3.66
55801 *CAP/HPS50/120 S76/35R/120/K 20 120 30 1.19 68 2.68
S68/50R/120/K
55803 CAP/HPS70/120 S62/70R/120/K 28 120 30 1.19 78 3.08
55805 *CAP/HPS70 S62/70HX/4T/K 7 300 30 1.19 68 2.68
55807 *CAP/HPS100/120 S54/100R/120/K 46 120 40 1.58 68 2.68
55809 CAP/HPS100 S54/100HX/4T/K 10 280 30 1.19 78 3.08
55811 CAP/HPS150/120 S55/150R/120/K 55 120 40 1.58 78 3.08
55813 CAP/HPS150 S55/150HX/4T/K 14 280 35 1.38 78 3.08
55815 *CAP/HPS200 S66/200CWA/4T/K 28 240 40 1.58 68 2.68
55817 CAP/HPS250 S50/250CWA/4T/K 35 280 40 1.58 78 3.08
S50/250CWA/5T/K
OIL-FILLED
55867 CAP/MH400/OIL M59/400CWA/4T/K 24 400 45 1.78 83 3.27
M59/400CWA/5T/K
55869 CAP/MH1000 M47/1000CWA/4T/K 24 480 50 1.97 103 4.06
M47/1000CWA/5T/K
55819 CAP/HPS400 S51/400CWA/4T/K 55 240 50 1.97 103 4.06
S51/400CWA/5T/K
55821 CAP/HPS1000 S52/1000CWA/4T/K 26 525 50 1.97 104 5.63
S52/1000CWA/5T/K
Product
Number Product Code Halco Ballast Code Mfd Volts Diam. (mm) Diam. (in) Height
(mm) Height (in)
* Product will be discontinued when inventory is depleted
ELECTROMAGNETIC HID BALLASTS
TOC
246
Ignitor Guide
55907 IGN/MH1 35W - 150W PS MH
35.6 1.4 66.0 2.6
55909 IGN/MH2 175W-450W PS MH
55901 IGN/HPS1 35W - 150W HPS
55903 IGN/HPS2 200W - 400W HPS
55905 IGN/HPS3 1000W HPS
Product Number Product Code Ballast Diam. (mm) Diam. (in) Height (mm) Height (in)
ELECTROMAGNETIC HID BALLASTS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
Cross Reference Guide
HALCO ADVANCE UNIVERSAL/
MAGNETEK HOWARD
Pulse Start Metal Halide
M102/150HX/4T/K 71A5492-001D M150MLTLC3M500K M0150-71C-512-K
M110/50HX/4T/K 71A5191-001D M50MLTLC3M500K M0050-23C-511-K
M141/1000CWA/4T/K 71A6593-001 P1000MLTAC5M500K M1000-71C-612-K
M141/1000CWA/5T/K 71A6552-001D P1000ML5AC5M500K M1000-81C-611-K
M149/750CWA/4T/K 71A64F2-001D P750MLTAC5M500K M0750-71C-612-K
M149/750CWA/5T/K 71A6452-001D P750ML5AC5M500K M0750-81C-612-K
M131/350CWA/4T/K 71A5993-001D P350MLTAC4M500K M0350-71C-6E4-K
M131/350CWA/5T/K 71A5953-001D P350ML5AC4M500K -
M132/320CWA/4T/K 71A5892-001D P320MLTAC4O500K M0320-71C-6E4-K
M132/320CWA/5T/K 71A5852-001D P320ML5AC4L500K -
M135/400CWA/4T/K 71A6092-001D P400MLTAC4L500K M0400-71C-6E3-K
M135/400CWA/5T/K - P400ML5AC4M500K -
M138/250CWA/4T/K 71A5792-001D P250MLTAC4L500K M0250-71C-611-K
M138/250CWA/5T/K - P250ML5AC4M500K -
M150/125CWA/4T/K - - -
M90/100HX/4T/K 71A5390-001D M100MLTLC3M500K M0100-71C-512-K
M98/70HX/4T/K 71A5292-001D M70MLTLC3M500K M0070-71C-511-K
Standard Metal Halide
M48/1500CWA/4T/K 71A6772-001D M1500MLTAC5M500K M1500-71C-214-K
M48/1500CWA/5T/K - - -
M47/1000CWA/4T/K 71A6572-001 M1000MLTAC5M500K M1000-71C-214-K
M47/1000CWA/5T/K 71A6552-001 M1000ML5AC5M500K M1000-81C-213-K
M57/175CWA/4T/K 71A5570-001D M175MLTAC3M500K M0175-71C-214-K
M57/175CWA/5T/K - M175ML5AC3M500K M0175-81C-214-K
M58/250CWA/4T/K 71A5771-001D M250MLTAC3M500K M0250-71C-215-K
M58/250CWA/5T/K 71A5750-001D M250ML5AC3M500K M0250-81C-215-K
M59/400CWA/4T/K 71A6071-001D M400MLTAC4M500K M0400-71C-213-K
M59/400CWA/5T/K 71A6051-001D M400ML5AC4M500K M0400-81C-212-K
TOC 247
ELECTROMAGNETIC HID BALLASTS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
248
Cross Reference Guide
ELECTROMAGNETIC HID BALLASTS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
High Pressure Sodium
S50/250CWA/4T/K 71A8271-001D S250MLTAC4M500K S0250-71C-214-K
S50/250CWA/5T/K 71A8251-001D S250ML5AC4M500K S0250-81C-212-K
S51/400CWA/4T/K 71A8473-001D S400MLTAC5M500K S0400-71C-212-K
S51/400CWA/5T/K 71A8453-001D S400ML5AC5M500K S0400-81C-212-K
S52/1000CWA/4T/K 71A8773-001 S1000MLTAC5M500K S1000-71C-212-K
S52/1000CWA/5T/K 71A8753-001 S1000ML5AC5M500K S1000-81C-212-K
S54/100HX/4T/K 71A8071-001D S100MLTLC3M500K S0100-71C-512-K
S54/100R/120/K 71A8007-001DB - S0100-02C-111-K
S55/150HX/4T/K 71A8172-001D S150MLTLC3M500K S0150-71C-512-K
S55/150R/120/K 71A8107-001DB - S0150-02C-111-K
S62/70HX/4T/K 71A7971-001D S70MLTLC3M500K S0070-71C-512-K
S62/70R/120/K 71A7907-001DB - S0070-02C-111-K
S66/200CWA/4T/K 71A8970-001D S200MLTAC4M500K S0200-71U-211-K
S68/50R/120/K 71A7807-001DB - S0050-02C-111-K
S76/35R/120/K 71A7707-001DB - S0035-02C-111-K
HALCO ADVANCE UNIVERSAL/
MAGNETEK HOWARD
SPECIFICATIONS
Ballast shall be designed in accordance with all applicable ANSI specications including
ANSI C82.4.
Ballast shall be designed with Class “H” (180°C) or higher insulation system.
All coils shall be precision wound.
Ballast shall operate for at least 180 cycles of 12 hours on and 12 hours off, when the lamp
circuit is in a short-circuited or open condition. This operation should cause no reduction in
ballast life.
Ballast and starter combinations shall operate reliably at starting temperatures of -40°C for
High Pressure Sodium ballasts and -30°C for Metal Halide ballasts.
Ballast shall not contain PCBs.
Manufacturer shall provide written warranty against defects in material or workmanship
for 2 years from date of manufacture.
Capacitors
All capacitors provided shall have a self-contained internal bleeder resistor.
All oil-lled capacitors shall have 0.25” quick disconnect terminals and be housed in
corrosion-resistant steel cans.
All required capacitors will be provided by the ballast manufacturer.
Ignitors
All ignitors will be epoxy-lled with a plastic external housing.
All ignitors shall be designed to provide six months of open circuit operation without failure.
Ballast shall have a lamp end-of-life detection and shut down circuit.
Ballast shall not contain PCBs.
Manufacturer shall provide written warranty against defects in material or workmanship
for 3 years from date of manufacture.
TOC 249
Specications
ELECTROMAGNETIC HID BALLASTS
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
APPENDIX
How to Measure a Lamp
Filament Lamp Construction
Glossary of Terms
Lamp Warranty
Ballast Warranty
251
251
252
265
266
CONTENTS
main
TOC
Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOC
How To Measure A Lamp
DIA: The diameter of a bulb at its widest point,
measured in eighths of an inch.
MOL: Maximum Overall Length from the top of
the bulb to the bottom of the base, measured
in inches.
LCL: Distance from the center of the light
source to the bottom of the base, measured
in inches.
MOL
DIA.
DIA.
LCL
MOL
B
D
E
C
FG
H
A
Long life lamps utilize long,
thick coiled laments.
Lamp bases made with brass
or nickel-plated brass do not
freeze or corrode in the socket.
Argon and Nitrogen gases are
used for washing and lling lamps.
Special chemicals are applied
inside lamp and on the lament to
protect against premature failure.
Filament Lamp Construction
Long life lamps utilize ve lament
supports to enhance longevity and
guard against lament sagging and
breakage.
Stem type is matched to lamp
type to enable exact position-
ing of lament.
Tempered glass stem provides
strength and durability.
Fused lead - wire carries electricity
from the base to the lament and
guards against potential re hazards.
251
APPENDIX
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
252
APPENDIX
2-Tap: HID ballast that operates at two input voltages:
120, 277.
4-Tap: HID ballast that operates at four input voltages:
120, 208, 240, 277.
5-Tap: HID ballast that operates at ve input voltages:
120, 208, 240, 277, 480.
Accent Lighting: Directional lighting used to highlight a
particular object or area.
Acoustic Resonance: A phenomenon that can occur when
using electronic ballast that operates at a high frequency
with a high intensity discharge lamp. What can happen is the
frequency of the ballast creates a harmonic in the lamp, causing
distortion of the arc and subsequent vibration of the arc tube.
This is most common in metal halide and ceramic discharge
metal halide lamps, and is less of a problem for high pressure
sodium. It is for this reason most electronic metal halide ballasts
are low frequency square wave ballasts as the lower frequency
avoids this problem.
Alternating Current (AC): Electron flow that periodically
reverses polarity and direction of travel through a circuit.
Ambient Lighting: The overall general lighting in an area or
room.
Ambient Temperature: Refers to the temperature of the air
around the device specied.
Ampere (amp): A standard unit of measurement of electrical
current. Amps = Watts / Voltage
ANSI (American National Standards Institute): The
organization that develops voluntary guidelines and product
performance standards for the electrical and other industries.
ANSI Ballast Type: A reference to the ANSI document which
describes the lamp and lists the characteristics of the ballast
required to operate the lamp. For HID lamps this is a code
with a letter prex followed by numbers. The following naming
system is used:
H – mercury lamps; M – metal halide lamps; S high pressure
sodium lamps; L – low pressure sodium lamps. ANSI codes
must match for a lamp and ballast to be compatible.
ANSI Lamp Codes: These are 3-letter codes assigned by the
American National Standards Institute. They provide a system
of assuring mechanical and electrical interchangeability among
similarly coded lamps from various manufacturers. Often found
in halogen lamps.
Arc: Intense luminous discharge formed by the passage of
electric current across a distance between electrodes.
Arc Tube: A completely sealed quartz or ceramic tube where
an electrical arc occurs and generates light.
Argon: Inert gas used in incandescent and uorescent lamp
types. In incandescent light sources, argon retards evaporation
of the lament.
Auto-Transformer: A type of transformer that electrically
connects the primary and secondary coils. This type of circuit
is used to make many ballasts smaller and more efcient.
Average Rated Life: An average rating, in hours, indicating
when 50% of a large group of lamps have failed, when operated
at nominal lamp voltage and current. Manufacturers use 3
hours per start for uorescent lamps and 10 hours per start
for HID lamps when performing lamp life testing procedures.
Every lamp type has a unique mortality curve that depicts its
average rated life.
Ballast: A device used to obtain the necessary circuit conditions
(voltage, current and waveform) for starting and operating an
electric-discharge lamp. All uorescent and HID light sources
require a ballast for proper operation.
Ballast Case Temperature: Used as a reference point in
design, temperature of ballast in situation when measured at
the ballast hot spot. See Maximum Case
Temperature.
Ballast Cycling: Intermittent operation due to high temperature
condition of the ballast or ambient temperature, which causes
the thermal protector to open and turn off the ballast. After
cooling down, the thermal protector closes, turning on the
ballast and starts the heating cycle over again. This is different
from lamp cycling, which is caused by voltage rise in a lamp-
reaching end of life.
Ballast Efcacy Factor (BEF): The ratio of a ballasts’ light
output to input power. Useful for comparing the efciency of two
different ballasts on a light output to power consumption basis.
BEF =% Ballast Factor/Input Power (Watts)
Ballast Factor (BF): The measured ability of a particular ballast
to produce light from the lamp(s) it powers. Ballast factor is
derived by dividing the lumen output of a particular lamp/
ballast combination by the lumen output of the same lamp(s)
on a reference ballast.
Ballast Hot Spot: The measurement point on a ballast that is
the highest temperature point during normal operation, and is
used in design when referencing the ballast case temperature
and maximum case temperature.
Ballast Kit: A kit developed to include all necessary parts for
the installation of a new ballast. For HID ballast kits this includes:
ballast, capacitor, ignitor (if used) and all necessary mounting
hardware. For CFL kits this includes: ballast, mounting plate,
lead wire set, wire-removal tool and mounting hardware.
Glossary of Terms
Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOC 253
APPENDIX
Ballast Loss: The total power lost in the operation of the ballast
measured in watts. This power is given off as heat energy. It is
equivalent to the difference between the input power and the
lamp wattage.
Base: The base holds the lamp in place in the xture and
conducts electricity from the circuit to the lamp. It can be
designed to dissipate heat.
Beam Angle: The angle of the cone of light emitted from a
light source or luminaire. This is often used to describe the light
distribution of a reectorized lamp (such as R and PAR types)
or an LED replacement product and encompasses the central
part of the beam out to the angle where the intensity is 50% of
the maximum. This is referred to in degrees. The beam angle
(sometimes called “beam spread”) is often part of the ordering
code for reectorized lamps. See also eld angle.
Beam Spread: See Beam Angle.
Binning: A systematic process of dividing LEDs into smaller
subgroups with a similar brightness and chromaticity
distributions. Halco minimizes color variation by utilizing binning
for LEDs used in ProLED lamps at +/- 200K.
Bi-Pin Fluorescent: A lamp design utilizing two pins on
each end of a uorescent lamp tube. This is crucial to provide
cathode heating voltage between the two pins for rapid start
and programmed start operations. These lamp can also be used
on instant start ballasts that are rated to run them.
Bi-Pin-Halogen or Incandescent: A lamp design using two
pins rather than a screw in or twist lock base to provide power
to heat the lament. Most often used in low voltage lighting
for JC halogen capsules and MR-type lamps, there are line
voltage versions.
Black Body (Planckian radiator): A theoretical ideal thermal
radiator whose SPD curve is dened by its temperature in Kelvin
and whose color coordinates lie exactly on the Planckian curve.
Tungsten lamps (both incandescent and halogen) are close
enough to be considered blackbodies for the purpose of SPD.
Bottom Exit: A conguration with leads or a wire-trap on the
bottom or base of the ballast.
BR Lamp: BR is a term for Bulged Reector, and refers to a
shape of blown glass reector lamps with a “stepped” reector
for better light extraction.
Canadian Energy Standards: Note on label that indicates that
the ballast complies with the Canadian Energy Standards and
meets the requirements of CAN/CSA-C654-M91.
Canadian Standards Association (CSA): An association that
generates product performance and safety standards for many
Canadian industries.
Candela: The measure of luminous intensity of a source
in a given direction. The term has been retained from early
lighting sciences when a standard candle of a xed size and
composition was dened as producing one candela in every
direction. A plot of intensity versus direction is called a candela
distribution curve and is often provided for directional lamps
and luminaires with a lamp operating in them.
Candelabra base: Small screw base for lamps, also known
as an E12 base.
Candlepower: Obsolete term for luminous intensity,
see Candela.
Candlepower Distribution: The candlepower at various angles
from a light source show in a numerical table and in a graph
known as the luminous intensity distribution curve. This data
can be found in photometric reports and is used to understand
how the light source will illuminate the area being lit.
Capacitor: A device that can be used to store energy in an
electric circuit. This is done via an electric eld between two
closely spaced conductors.
Cathode: Tungsten laments that emit electrons in a uorescent
lamp, and are often coated in an emissive material to assist
in starting. Negatively charged free electrons emitted by the
cathode are attracted to the positive electrode (anode), creating
an electric current between the two electrodes, generating the
UV that is converted into visible light by the phosphor.
Cathode Guard: Metal band encircling the cathode of a
uorescent lamp, used to collect the evaporating particles from
the cathode, greatly reducing end-blackening.
CDM: See Ceramic Discharge Metal Halide.
CDMH: See Ceramic Discharge Metal Halide.
Center Beam Candlepower (CBCP): Refers to the luminous
intensity at the center of the beam of a reector lamp; measured
in candelas.
Ceramic Discharge Metal Halide: A type of metal halide
discharge lamp that uses a translucent alumina (ceramic)
material for the arc tube instead of glass quartz. This material
is stronger and has higher heat and chemical tolerances than
quartz, allowing a different chemical mix to be used which
results in better color rendering (>80 CRI) and improved
lumen maintenance without sacricing efcacy. Halco ceramic
discharge metal halide lamps feature a 1-piece arc tube design
that delivers excellent color consistency and lamp reliability.
Also known as Ceramic Metal Halide, CDM, CMH or CDMH.
Glossary of Terms
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
254
APPENDIX
Ceramic Metal Halide: See Ceramic Discharge Metal Halide.
Chip: A very small square of semi-conducting material that is the
active light-emitting component of an LED. Also known as a die.
Chromaticity: The aspect of color that includes consideration
of its dominant wavelength and purity and is typically described
as a pair of coordinates on a color space.
CIE: Commission Internationale De L’Eclairage (International
Commission on Illumination): abbreviated as CIE from its French
title, is an organization devoted to international all matters
relating to the science and art of lighting.
Class H: An operating temperature classication for electrical
components established by Underwriters Laboratories. Allows
operation up to 180°C.
Class P: A classification for thermally protected ballasts
established by Underwriters Laboratories. In Class P ballasts,
internal thermal cutoff removes the input power when the
specied temperature limits are exceeded.
CMH: See Ceramic Discharge Metal Halide.
Coefcient of Utilization (CU): The fraction of initial lamp
lumens that reach the work plane. It is a function of luminaire
efciency, room surface reectance, and room shape.
Coil: Windings of copper or aluminum wire around the core in
electromagnetic ballast that transforms the voltage from input
to output.
Color Corrected: Refers to a lamp with a special phosphor
or coating to give it a color rendering prole similar to natural
daylight.
Color Rendering Index (CRI): A measurement to rate a lamp’s
ability to render an object’s color on a scale of 0-100, the higher
the CRI, the more true to life colors appear, as they would in
natural daylight.
Color Spectrum: The visible light spectrum, ranging between
380 (violet) and 770 (red) nanometers in the electromagnetic
spectrum.
Color Temperature: The actual color of a light source, also
referred to as Correlated Color Temperature (CCT), measured
in degrees Kelvin (K). Typical color temperature is:
2700K Incandescent/Fluorescent - Warm White
3000K Halogen/Fluorescent - Soft White
3500K Fluorescent - White
4100K Fluorescent - Cool White
5000K Fluorescent - Natural White
6500K Fluorescent - Daylight
Compact Fluorescent Lamp: A small, uorescent lamp, often
used as an alternative to incandescent lighting, that utilizes
small diameter tubes that are bent so that they begin and end
in a single base. The lamp life is about 10 times longer than
incandescent lamps and is 3-4 times more efcacious.
Consortium for Energy Efciency (CEE): An organization that
qualies and promotes energy efciency products including high
performance and reduced wattage linear uorescent lamps
and ballasts. A growing number of utility programs across the
U.S. offer rebates for commercial and industrial customers that
purchase and install CEE listed T8 lamps and ballasts in new
construction, replacement and retrot projects.
Constant Current Driver: A current and voltage regulating
power supply often used to power LEDs. This methodology
produces more consistent color and helps maintain the life and
light of LEDs when used in a lighting device.
Constant Voltage Driver: A power supply that provides a
constant voltage (usually DC) to a device, and is often used to
power LED devices. This is more commonly used in LED string
or strip type devices.
Constant Wattage Auto-Transformer (CWA): A type of HID
ballast reactor that applies a constant wattage to the lamp and
uses an auto-transformer to step-up the voltage.
Cool White: A term commercially used to describe a color
temperature of around 4100K generated by a halophosphor
type uorescent lamp. The Cool White(CW) designation is used
most often for T12 lamps but also for other uorescent lamps
using halophosphors and having a CRI of approximately 62.
These types of lamp are falling out of favor for more efcient
Tri-Phosphor lamps. Cool White is also used to describe self-
ballasted CFLs with a color temperature of 4100K.
Core: A component of an electromagnetic ballast, which is
surrounded by the coil. Core is composed of steel laminations
or a solid ferrite material.
Core and Coil Ballast: Another term for an electromagnetic
ballast.
Cove Lighting: Refers to light sources mounted above a ledge
or in a recess that distribute light upward for ambient lighting.
CoverShield: A safety coated Halco lamp that is protected
against rupture if it is dropped, struck or experiences thermal
shock. Often used for food service, daycare and medical
facilities.
Crest Factor (Lamp Current Crest Factor): The ratio of the
peak lamp current to RMS or average lamp operating current.
High current crest factors are detrimental to lamp life and
performance. ANSI standard for lamp current crest factor is
<1.7.
Glossary of Terms
Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOC 255
APPENDIX
CSA: Canadian Standards Association. An association that
generates product performance and safety standards for many
Canadian industries.
cUL: Approval from Underwriters Laboratories for use in
Canada.
Current: A measure of the rate of ow of electricity, expressed
in amperes (A).
Cycling: This is used to describe a condition where a lamp will
turn on for a short period, then turn off for a period of time, and
then restart (starting the cycle over again). This is a common
end-of-life occurrence in High Pressure Sodium lamps, but
can be present in other types of HID lamps. For HID lamps this
occurs when the operating voltage of the lamp rises beyond
the ballast’s ability during warm-up, which causes the lamp to
shut down, and restart after it has cooled. In other situations, it
can be caused by an overheating situation where a temperature
sensor in either a lamp or xture shuts off power when the
ambient temperature gets too hot.
Daylight: A term used to describe a high correlated color
temperature light that has an appearance roughly equal to that
of midday sun, having a CCT of approximately 6500K. This type
of light typically provides very good contrast, but is considered
to have a “cold” and sometimes “harsh” feel.
Dedicated Voltage: A ballast designed to work on one specic
input voltage.
Design Amperes: The approximate current that the lamp will
draw at design voltage.
Design Lumens: Lumen value at 40% of rated average life.
Also called Mean Lumens.
Dichroic: A type of reector that is designed to allow infrared
waves to pass but reect the visible spectrum of light. Often
used on MR lamps, this is designed to provide a “cooler” beam
and have less direct infrared hitting the illuminated surface.
Die: See Chip.
Diffusion: The even redirection or spreading of light by a lens
or diffuser.
Diode: Typically a semiconductor that is a two-electrode device
with an anode and a cathode that passes current in only one
direction. It may be designed as an electron tube.
Directional Lighting: Illumination on the workplane or on an
object predominantly from a single direction.
Discharge Lamp: A light source that produces light by passing
a current between electrodes through a vapor or gas. Includes
uorescent and high intensity discharge lamps.
Double-Ended Lamp: Lamps that have two bases or points
of electrical connection that provide extra stability in rough
service applications.
Down Lighting: A direct lighting unit, usually small, that aims
the light downward. Can be recessed, surface mounted or
suspended.
Driver: A power supply that is used to power LEDs in a device.
Essentially serves the same purpose as a ballast, but for LEDs.
Dual Connection: A CFL ballast with both side and bottom
exits for the lead wires, allowing use for multiple applications
.
Dual Inline Package: Also known as DIP, this is a packaging
method for LEDs that the LED is located in a small reector,
and then totally encased in a transparent or colored plastic.
The heat is dissipated through the electrical pins, but is far less
effective at heat dissipation than an SMD package, limiting total
power dissipation potential and increasing lumen depreciation
rates signicantly.
Eco-Shield: Halco brand linear uorescent lamps that are
TCLP compliant due to their low mercury content and other
design features intended to prevent mercury from escaping
disposed of lamps.
Efcacy: The measure of lumen output per unit power supplied
to the product. Useful as a measurement of how effective the
light source is in converting electrical energy to lumens of
visible light. Expressed in lumens-per-watt (LPW), this measure
gives more weight to the yellow region of the spectrum and
less weight to the blue and red regions where the eye is not as
sensitive (also known as the photopic response curve).
Efciency: The efciency of a light source is simply the fraction
of electrical energy converted to light, i.e. watts of visible light
produced for each watt of electrical power with no concern
about the wavelength where the energy is being radiated.
For example, a 100-watt incandescent lamp converts 7% of
the electrical energy into light; discharge lamps convert 25%
to 40% into light. The efciency of a luminaire or xture is the
percentage of the lamp lumens that actually comes out of the
xture. Efciency can also refer to a ballast or driver, and refers
to the ratio of power supplied to the lamp or LED to the input
power of the ballast or driver.
Electrical Discharge: A gas electrically conducting and
transmitting current, usually accompanied by the emission
of visible and other radiation. This is a principle behind many
energy saving technologies.
Electrode: An electrical conductor through which current enters
or leaves a medium such as an arc tube or gas lled lamp.
Electromagnetic Ballast: A low-frequency ballast that
operates through the use of current carrying coils assembled
on a magnetic core.
Glossary of Terms
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
256
APPENDIX
Electromagnetic Spectrum: A continuum of electric and
magnetic radiation that can be characterized by wavelength or
frequency, encompassing a wide range of energies from infrared
to visible to gamma rays. Visible light encompasses a small part
of the electromagnetic spectrum in the region from about 380
nanometers (violet) to 770 nanometers (red) by wavelength.
Electronic Ballast: A ballast that uses semiconductor
components to increase the frequency of uorescent lamp
operation (typically in the 20-40 kHz range). Smaller inductive
components provide the lamp current control. Fluorescent
system efciency is increased due to high frequency lamp
operation. Results are increased lamp efcacy, reduced ballast
losses and lighter, smaller ballasts compared to electromagnetic
ballasts. Electronic ballasts may also be used with HID (high
intensity discharge) lamps.
Electronic Component: A device or part employed in an
electronic circuit to obtain some desired electronic action.
Electronic Transformer: A device for converting electricity from
one voltage to another voltage that is comprised of electrical
components. This type of transformer changes the frequency
of power to the lamp, and often operates at over 20kHz. These
devices tend to be smaller and more efcient than magnetic
transformers but often have minimum load ratings that must
be met for use. These can have compatibility issues with other
electrical devices such as LED lamps.
Elliptical Reector: Incandescent lamp with a reector shell
that is elliptically shaped. Focuses light immediately in front of
the lamp, which reduces absorption and increases efciency.
EMI/RFI: Electromagnetic Interference or Radio Frequency
Interference. Unintentionally generated power during the
operation of a ballast that is capable of interfering with other
electrical devices operating at high frequencies.
End Blackening: Darkening around the ends of a uorescent
tube caused by particles evaporating from the cathode and
adhering to the glass. Lamps made with cathode guards greatly
reduce this occurrence.
End-of-Life (EOL) Protection: Circuit in a compact uorescent
ballast that removes power supply to the lamp during abnormal
lamp end-of-life. Ballast will reset when a new lamp is installed.
Energy: A measure of work done by an electrical system over
a given period of time; measured in kilowatt-hours (kWh).
Energy Policy Act (EPACT): Energy legislation originally passed
by Congress in 1992, and updated periodically, mandating
labeling and minimum energy efciency requirements for many
commonly used incandescent and uorescent lamps.
Energy Star®: U.S. Department of Energy (DOE) and
Environmental Protection Agency (EPA) administered program
that provides designation for certain products meeting energy
efciency and performance standards.
Energy Survey: Systematic cost comparison of an existing
system to a proposed system, accounting for electrical,
material, maintenance and labor costs.
EOL Protection Circuit: For all T5 and smaller lamps, there is a
circuit that monitors the operating parameters within the ballast
that, when normal operations are exceeded, will shutdown the
ballast.
Etch: Markings on the glass envelope or shell of a lamp
designating product description, logo and/or brand name.
Exclusionary Mogul Base: A variant of a mogul base designed
to prevent enclosed rated lamps from being used in an open
rated xture, which is also known as an EX39 base. This base
is only used in open-rated metal halide lamps and has the
bottom electrical contact protruding that allows the lamp to
make contact with the recessed electrical contact within the
exclusionary socket. The socket is pink in color to denote the
difference and help prevent confusion, as enclosed rated metal
halide lamps will not operate in this socket.
Exitance: The total light that comes off of a surface. Exitance
is dependent upon the illuminance on and reectance off the
surface.
Extended Life (XL): Sufx for ProLume T5 and T8 lamps
with special cathode design and phosphors that provide
40,000 hours average rated life when operated with an instant
start ballast and up-to 46,000 hours when operated with a
programmed start ballast.
Eyeball: Fixture, usually recessed, which can be rotated to
point in a desired direction.
Field Angle: The light distribution cone from directional light
sources encompassing the central part of the beam out to the
angle where the intensity is 10% of maximum. See also Beam
Angle.
Filament: Wire used in incandescent lamps, usually made of
tungsten and often coiled, that emits light when heated by an
electrical current.
Fixture: Luminaire without lamps.
Floodlight: A reector lamp designed to produce a broad,
relatively diffused beam of light.
Glossary of Terms
Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOC 257
APPENDIX
Fluorescence: The emission of electromagnetic radiation light by
a substance that has absorbed radiation of a different wavelength.
In most cases, absorption of light of a certain wavelength induces
the emission of light with a larger wavelength (and lower energy).
Fluorescence can be either wide-band (emitting a wide range
of wavelengths such as halophosphors or LED phosphors) or
very narrow (such as those used in a tri-phosphor lamp).
Fluorescent Lamp: A glass tube coated on the inside with
a uorescent substance that gives off light when a stream of
electrons from the cathode excites mercury vapor in the tube.
Flux: The basic measure of light ow that includes only visible
light and is weighted to match the response of the human eye;
measured in lumens.
Footcandle (fc): A unit measurement of direct illumination.
One footcandle is equal to one lumen per square foot.
Frequency: A measurement of the number of cycles per
second; the SI base unit is Hertz (Hz).
Full Spectrum: Broad spectrum light source capable of
producing colors throughout the entire range of the visible
spectrum, simulating actual sunlight.
General Lighting: Uniform light throughout an area, with no
special provisions for task lighting or accent lighting.
Glare: An interference with visual perception caused by an
uncomfortably bright light source or reection within one’s
eld of view.
Grounded Plane: Linear uorescent lamps must be within
a certain distance of a grounded metal plane with a width at
least the diameter of the lamp or 1 inch, whichever is greater.
This plane acts as a starting aid to the lamps and is important
to starting operations. The maximum distance between the
bulb wall and the starting aid (grounded plane) is as follows
per ANSI C78.81-2010:
Type of Fluorescent Lamp Maximum Distance
Inch mm
T5 Linear Lamps ¼ (0.25) 6
T8 Linear Lamps ¾ (0.75) 19
Other 500mA or less ½ (0.5) 13
Other greater than 500mA 1 25
Grounding: The connection of an electrical component that is
a conductor to “ground” or earth so that the electrical current
can pass off to it. A ballast or power supply with a ground input
or a metal housing should always be grounded. The grounding
helps assure safety and acceptable EMI/RFI performance.
Halogen Cycle: A regenerative cycle of tungsten and halogen
atoms, which prevents blackening of the lamp envelope during
the life of the lamp.
Halogen Lamp: An incandescent lamp with a lament that
is surrounded by halogen gases. Halogen gases allow the
laments to be operated at higher temperatures and higher
efcacies.
HaloXen: A Halco product line utilizing a halogen/xenon gas
mixture and specially designed laments that produces a
higher degree of energy efciency than standard incandescent
and halogen lamps. The heavier xenon gas reduces lament
evaporation and increases light output, while the halogen gas
maintains a clear glass wall and redeposits evaporated tungsten
back onto the lament, extending the lamp life and allowing
greater energy efciency.
Harmonic Distortion: Distortion of an AC waveform caused
by multiples of the fundamental frequency.
Head: Luminaire for a track-lighting system.
Hertz: A unit of frequency denoted as Hz. One Hz is equivalent
to one cycle per second. Can also be measured in kHz, or one
thousand cycles per second.
High Ballast Factor: Ballast with a nominal ballast factor of
above 1.0, and typically ends up approximately 1.18 for T8
lamps.
High Intensity Discharge (HID) Lamp: Metal Halide, High
Pressure Sodium, Low Pressure Sodium and Mercury Vapor
lamp types.
High Lumen (HL): Suffix for ProLume F32T8 lamps that
produce more light than standard lamps without consuming
additional power through the use of special phosphors. Often
used in conjunction with a low ballast factor ballast to provide
energy savings with minimal light loss.
High Output Fluorescent (HO): Fluorescent lamps designed to
be used with an 800 milliampere ballast. Able to operate at low
temperatures (down to 0°F) and still produce high light levels.
High Power Factor: A power factor above 0.90 or 90%.
High Power LED: Generally dened as a packaged light
emitting diode that consumes 1W or greater. See Light Emitting
Diode.
Glossary of Terms
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
258
APPENDIX
High Pressure Sodium (HPS) Lamp: High intensity discharge
light sources which produce light by an electrical discharge
through sodium vapor operating at relatively high pressures
and temperatures.
High Voltage: Voltages of 208 or higher.
High Wattage CFLs (or Spirals): Higher power compact
fluorescent lamps (65, 85, 105, 150 and 180 watts are
common power levels) which are used to replace high wattage
incandescent lamps or low wattage metal halide lamps (by
removing the ballast). These lamps are found in mogul and
medium base and typically have a long life.
HO (High Output): A lamp or ballast that operates at 800mA
is considered high output.
Hot Restrike Time: If there is a momentary power interruption
or the lights are turned off causing the HID lamp goes out, there
will be a delay of 3 to 15 minutes (depending on lamp type)
before the lamp has cooled down sufciently to start again.
HX-HPF: A high reactance auto-transformer that operates at a
high power factor. A type of circuit used in HID ballasts.
HX-NPF: A high reactance auto-transformer that operates at
a normal power factor. A type of circuit used in HID ballasts.
Ignitor: An electronic device providing a high voltage pulse
from 3000V to 6000V (depending on the ballast) to initiate an
electrical discharge in a gas lled tube. Typically, the ignitor is
paired with or is a part of the ballast. See also starter.
Illuminance: Light arriving at a surface, expressed in lumens
per unit area; 1 lumen per square foot equals 1 footcandle,
while 1 lumen per square meter equals 1 lux.
Illumination: The result of the use of light.
Incandescent Lamp: A light source that produces light by the
heating of a lament by an electric current.
Inches to Millimeters Conversion: To calculate the metric
equivalent of inches in millimeters (mm), multiply inches by 25.4.
Indirect Lighting: Luminaires that distribute 90 - 100 percent
of their light upward to be reected by the ceiling.
Induction Lighting: A means of lighting, which uses
RF induction of radio waves or microwaves to produce
luminescence. Induction lamps have no electrodes inside the
chamber and generally, therefore, have longer life than standard
incandescent lamps.
Infrared: Radiant energy in the wavelength range of about 770
to 1100 nanometers (nm). Energy in this range is not visible
to the naked eye, but can be sensed by the skin. Applications
include heat lamps, photography, medical therapy and industry.
InGaN: The main LED semiconductor technology containing
Indium, Gallium and Nitrogen to produce green, blue and
white-colored (with the help of phosphors) LED light sources.
Initial Lumens: The measured luminous output of a new light
source.
Input Voltage: Voltage required from a power supply for proper
operation of a ballast.
Input Watts: The total power input to the ballast which includes
lamp watts and ballast losses.
Instant Start: A type of uorescent lamp-ballast circuit designed
to start uorescent lamps as soon as the power is applied.
Originally, instant-start circuits were developed to eliminate
separate mechanical starter devices. Slimline uorescent lamps
operate only on instant start circuits.
Integrated Lamp: Generally refers to a non-incandescent
lamp with the ballast or driver integrated into the lamp shape
and capable of running on line or low voltage. A screw-based
compact uorescent lamp is an example of this.
Intensity: The light emitted from a source. Intensity varies given
the direction at which one views the source. Intensity does not
vary with distance.
Intermediate Base: Small screw base for lamps, also known
as an E17 base.
Kelvin Temperature: See Color Temperature.
Kelvins: Base unit for measuring color temperature, used in
lighting to describe appearance of light. See Color Temperature.
Kilowatt (kw): A measure of electrical power equal to 1000
watts.
Kilowatt Hour (kwh): The standard measurement of electrical
energy consumption. One kilowatt hour is equal to one kilowatt
of electricity used over the period of one hour. Also the typical
billing unit used by electrical utilities.
Krypton: A heavy inert gas used in incandescent lamps which
allows the lament to glow hotter and brighter and last longer.
L70 rating: The point at which a light source has depreciated
to 70% of the initial light output. This is commonly used as a
lifetime reference in LED lamps and xtures.
Lamp: Lighting industry term used for a light bulb.
Lamp Dimensions: Bulb designations consist of a letter(s)
to indicate shape and a number to indicate the diameter in
eighths of an inch.
Glossary of Terms
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
260
APPENDIX
Luminaire: A complete lighting unit including lamps, housing,
lens and ballast if required. All the necessary components to
make what we commonly refer to as a “xture”.
Luminaire Efciency: The ratio of total lumens exiting a luminaire
to those emitted by the lamp (or lamps) used in that luminaire.
Luminaire Efciency: The ratio of total lumens exiting a
luminaire to those emitted by the lamp (or lamps) used in that
luminaire.
Luminance (L): Light reected in a particular direction; the
photometric quantity most closely associated with brightness
perception, measured in units of luminous intensity (candelas)
per unit area (square feet or square meters).
Luminous Efcacy: The light output of a light source divided
by total input power of the source. See Lumens per Watt.
Lux (lx): A unit of illuminance equal to 1 lumen per square meter.
Magnetic Ballast: A ballast used with discharge lamps
consisting of conductive windings of copper or aluminum
around a steel or iron core. This type of ballast is similar in
construction to magnetic transformers, and does not have
any impact on the frequency of the lamp. In general these
ballasts are less efcient but more tolerant of temperatures than
electronic ballasts. See also Electromagnetic Ballasts.
Magnetic Transformer: A device for converting electricity from
one voltage to another voltage that is comprised of conductive
windings of copper or aluminum around a steel or iron core. This
type of transformer does not change the frequency of power
to the lamp. In general these transformers are less efcient but
more tolerant of temperatures than electronic transformers.
Maximum Case Temperature: This is the maximum
temperature when measured at the ballast “hot spot” that
can be maintained and not impact the life or performance
of a ballast negatively. Beyond this point the ballast will be
signicantly impacted and can have a short life and impact
lamp performance.
Maximum Overall Diameter (MOD): Maximum width or
diameter of a lamp taken on a plant perpendicular to the base
of the lamp. For most lamps this is referred to in a lamp’s
shape in 1/8” increments (ex. An A19 lamp is 19/8 inches in
diameter, or 2.375” diameter, and a T8 lamp is 8/8 inches in
diameter, or 1” in diameter). This measure becomes helpful in
determining t for CFL spirals, which do not typically follow this
naming convention.
Maximum Overall Length (MOL): The overall length of a lamp,
from the top of the shell to the bottom of the base.
Mean Lumens: The measured output of a light source at 40%
of lamp life. Also called design lumens.
Mean Spherical Candlepower (MSCP): The method of
rating the total light output of miniature lamps and the average
luminous intensity of an incandescent lamp in all directions.
MSCP can be converted to lumens by multiplying the MSCP
x 12.57.
Medium Base: The common term for an E26 screw base for
a lamp.
Mercury Vapor Lamp: A high intensity discharge light source
operating at a relatively high pressure (about 1 atmosphere) and
temperature in which most of the light is produced by radiation
from excited mercury vapor. Phosphor coatings on some lamp
types add additional light and improve color rendering.
Metal Halide Lamp: A high intensity light source in which the
light is produced by the radiation from mercury, plus halides
or metals such as sodium, scandium, indium and dysprosium.
Some lamp types may also utilize phosphor coatings.
Miniature Candelabra Base: Small screw base for lamps also
known as an E11 base.
Mini-Can: Usually refers to a line voltage halogen lamp with a
miniature candelabra base. See Miniature Candelabra Base.
Minimum Starting Temperature: References the minimum
ambient temperature that the ballast will reliably start a lamp.
Mogul Base: Large lamp base typically used for high power
incandescent, compact fluorescent, and high intensity
discharge type lights, also known as an E39 base.
Multi-Volt: A uorescent electronic ballast that has a universal
input voltage; typically these ballasts have an acceptable input
voltage range of 108V to 305V.
Nanometer: A unit of length equal to 10-9 meters; commonly
used as a unit of wavelength.
National Electric Code (NEC): A nationally accepted electrical
installation code to reduce the risk of re, developed by the
National Fire Protection Association.
National Electrical Manufacturers Association (NEMA):
Trade organization represented by around 450 manufacturers
of electrical supplies. NEMA develops product design,
manufacturing and performance standards that are designed
to benet manufacturers and consumers alike.
Natural White: A term to describe uorescent lamp that has
a high correlated color temperature, typically around 5000K.
This color temperature tends to be perceived as brighter but
somewhat harsher.
NEMA Premium Ballast: Designation that recognizes the
lighting industry’s most energy efcient T8 ballasts available.
Qualifying ballasts carry the NEMA Premium mark on the label.
Glossary of Terms
Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOC 261
APPENDIX
Neodymium: A rare earth element used to produce full
spectrum incandescent lamps; also know as daylight or natural
light. They use a colored glass shell to lter out the yellow light
produced by standard incandescent lamps.
Nominal Input Voltage: The input voltage at which the ballast
is designed to operate. The nominal voltage allows for normal
levels of variation without affecting ballast operation.
Nominal Length: A measurement for Fluorescent lamp length
based on the length of the lamp plus an allowance for the
luminaire’s lamp holders.
Nominal Open Circuit Voltage (OCV): The rated open circuit
voltage for a ballast, typically at the center of an acceptable
range for this ballast.
Normal Ballast Factor: Ballast with a nominal ballast factor of
between 0.80 and 1.00, and typically ends up approximately
0.88 for T8 lamps.
Normal Power Factor: A power factor below 0.90 or 90%.
Typically low power factor ballasts operate at <0.50 or <50%.
Ohm’s Law: A scientific law which states that current
(amperes) in a circuit depends on resistance (ohms) and
applied electromotive force (volts). Current (I) = Voltage (E) /
Resistance (R)
Open Circuit Voltage (OCV): Open Circuit Voltage measured
across the socket the lamp screws into, with the ballast powered
on. This can be difcult to measure in modern products with end
of life protection, and is often dangerous to measure without
appropriate knowledge of the ballast. Exceedingly high voltages
could be present in certain types of lighting products.
Operating Position: Lamps may be operated in any position
unless otherwise noted.
Operating Voltage: For electrical discharge lamps, this is
the voltage measured across the discharge when the lamp is
operating. It is governed by the contents of the chamber and is
somewhat independent of the ballast and other external factors
but still must fall within predetermined characteristics in order
to be compatible with the ballast.
PAR Lamp: PAR is an acronym for parabolic aluminized
reector. A PAR lamp, which may utilize either an incandescent
lament, a halogen lament tube or an HID arc tube, is a
precision pressed-glass reector lamp. PAR lamps rely on both
the internal reector and prisms in the lens for the control of
the light beam.
Parallel: A type of circuit in which the electrical pathway splits
and ows to each lamp simultaneously. In this type of circuit
each lamp is operated independently and therefore will continue
to operate even if the other lamp fails.
PCB (Polychlorinated Biphenyls): Chemical pollutant formerly
used in ballast capacitors that were part of ballasts. It is now
illegal to use PCBs and most such ballasts have been replaced
over time. No Halco ballasts have ever been produced with
PCBs.
Phosphor: A chemical compound typically found as a
powder that is deposited inside of the glass of a lamp, into the
encapsulent of a white LED, or applied over the emitting surface
of an LED. Phosphors are designed to absorb a specic type of
light (UV for discharge lamps, or blue light for LEDs) and re-emit
it as a longer wavelength with the purpose of providing visible
light or altering the characteristics of a visible light.
Photometry: The science of measuring visible light in units that
are weighted according to the sensitivity of the human eye to
certain wavelengths of light.
Photopic Vision: Refers to vision involving the cones of the eye;
used in reference to the adaptation of the eye to illuminance of
more than 3.4 candelas per square meter.
Pigtail: An adaptation to a uorescent ballast that connects
multiple wires together into one convenient socket. Most often
used for Circline lamps.
POMB: See Position Oriented Mogul Base.
Position Oriented Mogul Base: Mogul base lamp that has two
pins near the base of the threads. These pins follow a groove
in a Position Oriented Mogul Base Socket that ensures that a
horizontal-operation lamp is used in the correct position within
a xture. This base type is also referred to as a POMB.
Potting: A compound, typically made of asphalt and silica, that
is used to ll the inside of a ballast.
Power Factor: A measurement indicating how efficiently
a lighting system is using the power it is drawing. The ratio
between power used (watts) and power being drawn from the
line (volts-amperes). Expressed as a percent or a range from
0 to 1.0. The higher the percent the more efciently the power
is being used. High power factors are ratings of 0.9 (90%) or
higher. Incandescent lamps are close to 1.0, magnetic ballasts
can be as low as 0.5.
Power Factor Corrected: Ballasts that incorporate a means
of Power Factor Correction but whose power factor is <90%
and >50%.
Preheat Start: A uorescent lamp-ballast circuit where the
electrodes are heated or warmed by an auxiliary switch or
starter before the lamps light up.
Probe Start: A starting method for HID lamps that involves
the use of a probe to start the lamp. A large surge of voltage
is applied to the probe in order to assist in starting the lamp.
Glossary of Terms
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
262
APPENDIX
Programmed Rapid Start: See Programmed Start.
Programmed Start: A uorescent lamp-ballast circuit that uses
a custom integrated circuit (IC), which monitors lamp and ballast
conditions to ensure optimal system lighting performance. PS
ballasts heat the lamp cathodes to 700°C prior to lamp ignition.
This puts the least amount of stress on the lamp electrodes,
resulting in maximum lamp life regardless of the number of lamp
starts. Programmed-start ballasts are typically wired in series.
ProLED: Halco’s high performance, energy efcient LED line,
which features lamps designed to provide long life, precise
beam control, solid state construction and tightly controlled
color temperatures.
Pulse Start: A uorescent lamp-ballast circuit that is designed
with an ignitor to ignite the arc tube. Due to this, bulbs have no
need for the starter electrode. Pulse start lamps are typically
more efcient than standard counterparts.
Quartz: The commonly used name for fused silica which is
used to make high strength and high temperature tubes and
lamps in the lighting industry. Commonly used in Halogen
capsules, Metal Halide arc tubes, mercury vapor arc tubes
and the protective shroud in open-rated metal halide lamps.
Quartz-Halogen Lamp: See Halogen Lamp.
Radiation: A general term for energy released as a wave or ray.
Includes all forms of visible light, UV, IR, radio, heat waves, etc.
Radiometry: The science of measuring radiant energy, especially
radiant energy in that portion of the total electromagnetic
spectrum lying adjacent to the visible region.
Rapid Start: A uorescent lamp-ballast circuit which utilizes
continuous cathode heating, while the system is energized, to
start and maintain lamp light output at efcient levels. Rapid
start ballasts may be either electromagnetic, electronic or of
hybrid designs. Full-range uorescent lamp dimming is only
possible with rapid start systems.
Rated Lamp Life: See Average Rated Life.
Reactor: The most basic circuit type for an HID ballast, made
of a single coil, which acts as an inductor.
Reference Ballast: Laboratory device used to provide ANSI-
specied measurements of initial and mean lamp lumens.
Reflector Lamp: An incandescent, halogen compact
uorescent or HID lamp with a built-in reecting surface.
Incandescent and HID versions are made from a single piece
of blow-molded soft or hard glass.
Reector Optic: A reective secondary optic that is used to
convert wide-emitted light into a different shape and light ray
distribution pattern.
Refraction: The bending of light rays.
Refractor: A translucent xture covering, such as a lens or
diffuser that refracts or bends light rays.
Resistance: A measure of resistance to ow of electrical
current, expressed in ohms.
RFI: See EMI/RFI.
RGB – also Colormixing: Red, green and blue colors can be
added and mixed to generate a wide range of colors. RGB
control schemes typically employ pulse width modulation to dim
one or more of the primary colors to generate the desired effect.
Scotopic/Photopic (S/P) Ratio: This measurement is a
reference to account for the fact that of the two light sensors
in the retina, rods are more sensitive to blue light (scotopic
vision) and cones to yellow-green light (photopic vision). S/P is
calculated as the ratio of scotopic lumens to photopic lumens
for the light source on an ANSI reference ballast (if applicable).
Higher-color temperature lamps tend to have higher values of
the S/P Ratio compared to lower CCT sources. It is important to
note that many situations will not fall purely into either photopic
or scotopic vision.
Scotopic Vision: Sight involving the eye’s rods, which respond
to low levels of lighting, below .034 candelas per square meter.
Secondary Optic: A glass, metal or plastic element used in
LEDs and luminaires to change the direction and control the
distribution of light rays.
Self-Ballasted Lamps: See Integrated Lamp.
Series: A type of circuit in which the current ows through
the lamps in sequence. The failure of one lamp results in the
stoppage of current ow.
Shimmer: Changes to the intensity of a lamp that are not visible
from looking directly at the lamp or lit area, but are noticeable
in the peripheral vision.
Shroud: A glass cylinder surrounding the arc tube in metal
halide lamps to protect against the hot arc tube from breaking
the glass bulb if an arc tube rupture occurs. It reduces the risk
of using metal halide lamps in open xtures.
Single-Ended Lamp: Lamps that have one base or point of
electrical connection.
SI: International System of Units. Most widely used standards
for measurement.
Slim Case: A reduced size case for uorescent ballasts to allow
for more versatile applications.
SMD: See Surface Mount Diode.
Glossary of Terms
Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOC 263
APPENDIX
Glossary of Terms
Surface Mount Diode: A type of LED package for mounting
to the surface of a circuit board. This format allows for better
thermal dissipation for the diodes and helps maintain the long
life of LEDs. See LED Package.
Task Lighting: Lighting directed to a specic surface or area
that provides illumination for specic tasks.
TCLP Test: The Toxicity Characteristic Leaching Procedure
(TCLP) test, specified in the Resource Conservation and
Recovery Act (RCRA) of 1990, is used to characterize
uorescent lamp waste as hazardous or non-hazardous waste.
The TCLP test measures the ability of the mercury in a lamp to
leach from a landll into ground water under very aggressive
and reactive conditions.
Thermal Protector: A device used in a ballast to detect when
the maximum temperature of the ballast has been exceeded
and when to remove input power. Thermally protected ballasts
that meet UL certications are classied as “Class P.”
Total Internal Reflection Optic: A glass or transparent
plastic secondary optic that uses the principle of Total Internal
Reection (TIR) to efciently direct the light rays of an LED from
the wide emitting pattern into a different beam distribution. Most
commonly composed of PMMA plastic.
Total Harmonic Distortion (THD): A measure of the distortion
of an electrical wave form. Excessive THD may cause adverse
effects to the electrical system.
Transient Protection: See TVSS.
Transients: High voltage surge through an electrical system
that can lead to premature ballast or integrated lamp failure.
A transient may be caused by lightning strikes to nearby
transformers, lines or ground, or by switching of motors or
compressors (via inductive kick), as well as by circuit shorts.
Tri-Phosphor: Term used to describe fluorescent lamps,
including most compact fluorescent lamps, which use a
combination of at three phosphors (red, green and blue) to
generate white light efciently and with good color rendering.
Trigger Start: A circuit that eliminates the starter and allows
for instant starting of preheat lamps.
Troffer: A long recessed lighting xture, usually installed ush
with the ceiling.
Tungsten Halogen Lamp: See Halogen Lamp.
TVSS: Transient Voltage Surge Suppressors. These are devices
that are installed to protect ballasts and other electronic
equipment from transients that may occur in the power line.
Soft White (uorescent): A term to describe a uorescent
lamp that has a low correlated color temperature, typically
around 3000K.
Soft White (incandescent): A lamp with a silica coating on the
inside of the bulb to provide very diffuse light and completely
conceal the lament.
Solid State Lighting: Lighting based on the use of
semiconductors, see Light Emitting Diode.
Sound Rating: A rating of the amount of sound produced in
the normal operation of a ballast. “A” is the normal favorable
rating, producing the lowest amount of sound, while “E” is
the least favorable rating, producing the greatest amount of
audible noise.
SOX: Low Pressure Sodium abbreviation term.
Spectral Power Distribution: Distribution of spectral emissions
from a lamp, in either relative terms or absolute terms, used
to determine CCT and chromaticity of a light source. Often
accompanied by a visual representation of the radiant energy
emitted by a light source as a function of wavelength. SPDs
provide a visual prole or “ngerprint” of the color characteristics
of the source throughout the visible part of the spectrum. Also
called “spectral curve” or “spectrum”.
Spiral Lamp: A helical-shaped long life compact uorescent
lamp.
Spotlight: A lamp designed to produce a narrow beam angle
to illuminate a specically dened area.
SSL: See Solid State Lighting.
Starter (Ignitor): A device used in conjunction with a ballast to
start preheat uorescent lamps.
Striation: Describes a condition in a uorescent lamp where
a series of bright and dim areas are exhibited, and sometimes
move down the length of the lamp. These are common in
reduced wattage lamps, which use heavy ll gasses such as
Krypton. It is not an indication of a ballast or lamp problem and
will not impact the lamp or ballast, and are most often seen
during lamp warm-up or when the temperature on the outside
wall of the lamp is too low.
Super CWA: Constant wattage, Auto-Transformer for use with
Pulse Start Metal Halide Lamps.
SureColor: Prism MR16 lamps that feature a UV-stop quartz
capsule, titanium coated dichroic reector for consistent color,
and an axial lament for precise beam control.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
264
APPENDIX
Glossary of Terms
Warm White: Refers to a low color temperature of light,
nominally refers to light with a correlated color temperature of
3000K or 2700K, resulting in a yellow-white light. Typically refers
to discharge or LED products, as halogen and incandescent
light tend to fall in this category naturally.
Watt: A unit of electrical power. One watt is equal to one ampere
of current owing through one ohm of resistance.
Wavelength: Distance between two successive points of
a periodic wave; the wavelengths of light are expressed in
nanometers (nm).
Two-Pin Compact Fluorescent Lamps: Type of lamps that
have a starter integrated into the base of the lamp. Traditionally
2-pin lamps are designed to work with magnetic ballasts.
UL: Underwriters Laboratories. Laboratory that sets safety
standards for building materials, electrical appliances and
other products.
Ultraviolet: Radiant energy in the wavelength range of about
100 to 380 nanometers (nm). This light is invisible to the naked
eye and is also known as black light. Applications include:
Blacklight 320-400 nm
Germicidal 220-300 nm
Ozone-producing 180-220 nm
Very High Output (VHO) Lamps: Fluorescent lamps designed
to be used with a 1500 milliampere ballast.
Visible Spectrum: Radiant energy in the wavelength range of
about 380 to 770 nanometers (nm). The light that can be seen
by the human eye and produces what we also call the “color
spectrum.”
Volt: The unit of electromotive force (emf). The difference in
electrical potential that will cause a current of one ampere to
ow through a resistance of one ohm.
Voltage Rating: The recommended operating voltage for a
lamp.
Voltage Sag: Drop in voltage levels of electrical distribution
system or electrical circuit that interferes with the operation
of electrical and electronic equipment. Commonly called a
“Brownout”. Results when demand for electricity exceeds
capacity of the distribution system, and is more common in
some areas of the country.
Voltage Surge: See Transient.
Warm-Up Time: The time it takes a lamp to get to full
brightness. Incandescent, Halogen and LED lamps have
effectively no warm up time. Discharge lamps do not come on
at full brightness upon startup and:
· Most uorescent lamps come on at 80% or greater
brightness and warm up the rest of the way very
quickly.
· Covered compact fluorescent and amalgam
uorescent lamps start at a lower brightness and can
take up to 3 minutes to reach full brightness.
· HID lamps take 3-10 minutes to warm up to full
brightness after starting and typically start at a very
low proportion of brightness.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOC 265
APPENDIX
Lamp Warranty
HALCO LIGHTING TECHNOLOGIES LAMP LIMITED WARRANTY
Halco Lighting Technologies (hereinafter called “Halco”), 2940 Pacific Drive, Norcross, GA 30071, warrants to the
purchaser that Halco lamps will be free from defect in the material and workmanship from the date of manufacture for
the following time periods:
Lamp Category Warranty
Self-Ballasted CFL 42 watts or less: 2 years
Self-Ballasted CFL greater than 42 watts: 1 years
Plug-in Compact Fluorescent: 1 years
High Power LED: 5 years
IP65 Rated JC LED (40,000 hour rated life): 5 years
Standard JC LED (20,000 hour rated life), C7 and C9 LED: 2 years
Linear Fluorescent, non-pre-heat > 14 watts: 2 years
ProLume Linear Fluorescent, non-pre-heat > 14 watts
operated on a ProLume Ballast: 3 years
Explicit Operating Conditions:
Self-Ballasted and Plug-In Compact Fluorescent Lamps: Based on maximum of 10 hours use per day.
Should any product fail to meet the warranty specified above, Halco, at its option, shall correct any defect by issuing a credit for the product or providing a free
replacement lamp. This warranty is conditioned upon proper storage, installation, use and maintenance. Remedy is expressly limited to credit or replacement only.
This warranty is not applicable to any lamp, which is not installed and operated in accordance with the current edition of the National Electric Code (NEC), the
Standards for Safety of Underwriters Laboratory, Inc. (UL), the Standards for the American National Standards Institute (ANSI), and with Halco instructions and
guidelines for the lamp. This warranty is not applicable to any lamp subjected to abnormal stresses and operating conditions. Use of occupancy sensors, dimmers
or programmable systems with some lamp types may void the warranty.
Halco reserves the right to examine all lamps prior to the determination of warranty status. All lamps must be retained for warranty claims. The warranty period
starts on the date of installation. If the date of installation cannot be determined or is unknown, the warranty period will start with the date of the original purchase
from Halco.
Warranty Exclusion Clause for Products Exported:
This warranty shall be void for products that are exported outside of the U.S. and its territories. The distributor, private labeler or OEM assumes all responsibility
imposed by statue, regulation or law on products sold into these markets.
NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY BEYOND
THE AFOREMENTIONED WARRANTY PERIOD.
The foregoing warranty is exclusive of all other statutory, written or oral warranties, and no other warranties of any kind, statutory or otherwise, are given or herein
expressed. The warranty sets forth Halco’s responsibilities regarding the ballast and claimant’s exclusive remedy.
Warranty claims are to be made in accordance with Halco’s published Warranty Program, made available upon request.
LIMITATION OF LIABILITY. Halco will not under any circumstances, whether as a result of breach of contract, breach of warranty, tort, strict liability or otherwise,
be liable for consequential, incidental, special or exemplary damages including, but not limited to, loss of profits or revenues, loss of use of lamp or any other goods
or associated equipment or damage to any associated equipment, cost of capital, cost of substitute products, facilities of service, down time cost, or claims of
claimant’s customers. Halco’s liability on any claim of any kind for any loss of damages arising out of, resulting from or concerning any aspect of this agreement
from the products or services furnished hereunder shall not exceed the price of the specific lamp or lamps which gives rise to the claim.
Some states do not allow the exclusion of limitation of damages or the length of time for an implied warranty. Therefore, the limitations or exclusions of consequen-
tial or incidental damages and implied warranties may not apply to certain claimants. This warranty gives the claimant specific legal rights. The claimant may also
have other rights, which vary from state to state.
Quality Assurance Guarantee
At Halco Lighting Technologies, we are committed to quality and service. We measure our success by one standard, customer satisfaction. With this in mind, we
offer you the following: Should you encounter any product from Halco Lighting Technologies that fails to perform according to specifications, contact your account
representative immediately. If our product is found to be defective in either material or workmanship, we will credit your account or replace the product at no
charge. In order to better maintain our standard of quality, we reserve the right to inspect any defective products. We make this assurance to clearly demonstrate
our commitment to your satisfaction.
All other lamps are covered under our Quality Assurance noted below.
Halco Lighting Technologies | 800.677.3334 | halcolighting.com
TOC
266
APPENDIX
Ballast Warranty
HALCO LIGHTING TECHNOLOGIES LAMP BALLAST LIMITED WARRANTY
Halco Lighting Technologies (hereinafter called “Halco”), 2940 Pacific Drive, Norcross, GA 30071, warrants to the
purchaser that its ballasts will be free from defect in the material and workmanship from the date of manufacture for the
following time periods:
Ballast Category Warranty
Electronic Fluorescent: 5 years
ProFormance Electronic Fluorescent: 5 years
ProFormance Electronic Compact Fluorescent: 5 years
Electronic Residential: 5 years
Electromagnetic Compact Fluorescent: 3 years
Electronic Sign: 3 years
Electronic HID: 3 years
Core & Coil HID: 2 years
Should any product not meet the warranty specified above, Halco, at its option, shall correct any defect, by either repairing any defective part of
parts or by replacing any defective part or parts or by making available a new replacement ballast. This warranty is conditioned upon proper
storage, installation, use and maintenance.
This warranty is not applicable to any ballast, which is not installed and operated in accordance with the current edition of the National Electric
Code (NEC), the Standards for Safety of Underwriters Laboratory, Inc. (UL), the Standards for the American National Standards Institute (ANSI),
and with Halco instructions and guidelines for the ballast. This warranty is not applicable to any ballast subjected to abnormal stresses and
operating conditions.
The conditions of any tests [to be] performed on Ballast Products, which are claimed to have not performed in accordance with the terms of this
warranty, shall be mutually agreed upon in writing and Halco shall be notified of, and may be represented at such tests. Halco extends this express
limited warranty to the original purchaser.
NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY BEYOND
THE AFOREMENTIONED WARRANTY PERIOD.
The foregoing warranty is exclusive of all other statutory, written or oral warranties, and no other warranties of any kind, statutory or otherwise, are
given or herein expressed. The warranty sets forth Halco’s responsibilities regarding the ballast and claimant’s exclusive remedy.
Warranty claims are to be made in accordance with Halco’s published Warranty Program, made available upon request.
LIMITATION OF LIABILITY. Halco will not under any circumstances, whether as a result of breach of contract, breach of warranty, tort, strict
liability or otherwise, be liable for consequential, incidental, special or exemplary damagees including, but not limited to, loss of profits or revenues,
loss of use of ballast or any other goods or associated equipment or damage to any associated equipment, cost of capital, cost of substitute
products, facilities of service, down time cost, or claims of claimant’s customers. Halco’s liabitlity on any claim of any kind for any loss of damages
arising out of, resulting from or concerning any aspect of this agreement from the products or services furnished hereunder shall not exceed the
price of the specific ballast or ballasts which gives rise to the claim. Per the Halco Warranty Service Program, Halco will provide a maximum labor
allowance of ten dollars ($10.00) per ballast for Electronic Ballasts only.
Some states do not allow the exclusion of limitation of damages or the length of time for an implied warranty. Therefore, the limitations or exclusions
of consequential or incidental damages and implied warranties may not apply to certain claimants. This warranty gives the claimant specific legal
rights. The claimant may also have other rights, which vary from state to state.
Warranty Exclusion Clause for Products Exported:
This warranty shall be void for products that are exported outside of the U.S. and its territories. The distributor, private labeler or OEM assumes all
responsibility imposed by statue, regulation or law on products sold into these markets.

Navigation menu