2598 8/16-Point AC Discrete Output Module Specifications Outputs per Module: 8 or 16 Isolation: 2100 VAC channel-to-backplane 3000 VAC group-to-group Output Voltage: 11 VAC to 240 VAC The 2598 was designed to be primarily a 16pt module. However, in order to provide maximum flexibility for the user, it may also be configured as an 8 point module. Some details are listed below to help the user better understand the jumper settings and PCB labeling discrepancies for the 8 point setting. 8 Point Mode: Move jumper in “Login” box to location JP3 to choose 8pt mode. Ensure the Isolation jumpers J2,4,5, & 6 are in ‘8 Common’ positions to correspond to the Siemens® counterpart 8 point modules (2 inputs/ common). Also, note that many of the printed channels (CH 1-CH 32) on the PC board are no longer valid, nor are the front panel connector labels. (You may find it helpful to utilize the appropriate 8 pt. connector labels shipped with the product.) If 8 Point is enabled, the following table’s 8pt. row is the new correlation of PC board printing and front panel label’s LED area printing. For example, in 8 Point Login Configuration, the board marking for channel 10 (CH 10) would be the input channel 6. Likewise, the PC board marking for CH 13 would correlate to input channel 7. Login Mode Channel/Fuse Labeling 32 pt: 1 2 16 pt: 1 2 8 pt: 1 2 3 4 5 6 3 4 - - - - - - 7 - 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 - 5 6 7 8 - - 3 4 - - - - - - 9 10 11 12 - - - - - - 5 - - - 6 - - - 13 14 15 16 7 8 - - - - - - - - - Note: For CTI Limited Product Warranty and RMA procedures please go to www.controltechnology.com/support.htm. for Class 1 Div 2 locations: 2A per point @ 50C 1.5A per point @ 60C Maximum Surge Current: 3 Amps for 15 Sec “ON” State Voltage Drop: 1.0 V @ 1.0 Amp Product Bulletin 8/16 Point Configuration Explanation 2500 Series PLC System Maximum Output Current: 2A per point 8A per group 32A per module (16pt login) Description “OFF” State Leakage Current: 1 mA @ 120 VAC The 2598 8/16-Point AC Discrete Output Module provides eight or sixteen outputs from CTI 2500 Series or Simatic® 505 I/O bases. The module utilizes solid-state output circuits to switch on or off external devices such as pilot lamps, motor starters, or solenoids. The 2598 is designed to switch externally supplied 11 to 240 VAC. The internal logic signals are isolated from the external outputs to 2100 VDC. Turn On Time: 1 AC cycle Turn Off Time: 1 AC cycle Fuses: 16, 2.5 amp, 250V, Type Littlefuse #21602.5, Bussman GDA-2.5, (Field replaceable) Connector: Removable Wire Gauge: 14 - 22 AWG Backplane Power: 1.25 Watts max. Features 8 or 16 AC output points Replaces Siemens® 505-4608, -4616, -4808, -4816 3000 VDC group-to-group isolation 2100 VDC channel-to-backplane isolation Isolation in groups of four (16pt. login) or in groups of two (8pt. login) Wide 11-240 VAC output range 2.0 Amps per output Individually fused outputs Sourcing outputs Single-wide module Module Size: Single-wide Operating Temperature: 0o to 60oC (32o to 140oF) Storage Temperature: -40o to 85oC (-40o to 185oF) Relative Humidity: 5% to 95% (non-condensing) Agency Approvals: UL, UL-Canada, Class 1, Div 2, CE Shipping Weight: 1.5 lb. (0.68 Kg) Control Technology Inc. Copyright© 2006 Control Technology Inc. All Rights Reserved 5734 Middlebrook Pike, Knoxville, TN 37921-5962 Phone: 865/584-0440 Fax: 865/584-5720 www.controltechnology.com AC AC AR AR A5 A5 A1 A1 A6 A6 A2 A2 A7 A7 A3 A3 A8 A8 A4 A4 BC BC BR BR B5 B5 B1 B1 B6 B6 B2 B2 B7 B7 B3 Not Applicable: See explanation in section on back page B3 Not Applicable: See explanation in section on back page B8 B8 B4 B4 CC CC CR CR C5 C5 C1 C1 C6 C6 C2 C2 C7 C7 C3 C3 C8 C8 C4 C4 DC DC DR DR D5 D5 D1 D1 D6 D6 D2 D2 D7 D7 D3 D3 D8 D8 D4 D4 8 Pt Login Selection Jumper in 4 Common Position AC Not Used Channel 1 Channel 2 Not Used Not Used Not Used Channel 3 Channel 4 Not Used Not Used Not Used Channel 5 Channel 6 Not Used Not Used Not Used Channel 7 AR A5 A1 A6 A2 A7 A3 A8 A4 BC BR B5 B1 B6 B2 B7 B3 B8 B4 CC CR C5 C1 C6 C2 C7 C3 C8 C4 DC DR D5 D1 D6 D2 Channel 8 Not Used Not Used D7 D3 D8 D4 User Pwr AC(+) Channels 1-2 Not Used Not Used Not Used Not Used User Pwr AC(+) Channels 3-4 Not Used Not Used Not Used Not Used User Pwr AC(+) Channels 5-6 Not Used Not Not Used Not Used User Pwr AC(+) Channels 7-8 Not Used Not Used Not Used Not Used 8 Pt Login Selection Jumper in 8 Common Position Figure 3. Jumper and Fuse Configuration (see chart on back for actual channel correlations) 16 Pt Login Selection Jumper in 4 Common Position AC Not Used Channel 1 Channel 2 Channel 3 Channel 4 Not Used Channel 5 Channel 6 Channel 7 Channel 8 Not Used Channel 9 Channel 10 Channel 11 Channel 12 Not Used Channel 13 Channel 14 Channel 15 Channel 16 AR A5 A1 A6 A2 A7 A3 A8 A4 BC BR B5 B1 B6 B2 B7 B3 B8 B4 CC CR C5 C1 C6 C2 C7 C3 C8 C4 DC DR D5 D1 D6 D2 D7 D3 D8 D4 User Pwr AC (+) Channels 1-4 Not Used Standard Shipping Configuration Jumper Not Used Not Used Not Used User Pwr AC (+) Channels 5-8 Not Used Not Used User Pwr AC (+) Channels 9-12 Not Used J2, J4, J5, J6 8 Common JP 2, 3 JP2 - 16 pt. Login Table 1. Jumper Configuration Table Not Used Not Used Jumper Configuration Selection WARNING: Do not alter ‘8 COMMON’ jumper J2, 4, 5, and 6 settings. The module is configured as needed for proper wiring compatibility with its Siemens® counterpart. Remove the module from the 505 base before changing LOGIN jumper JP2 and 3 settings. Not Used Not Used Not Used User Pwr AC (+) Channels 13-16 Not Used Not Used Not Used Not Used 16 Pt Login Selection Jumper in 8 Common Position* *Note: Due to a new rev ‘C’ 2598/99 PCB, the 16pt login above differs from the former ‘B’ rev PCB. The one above is 100% Siemens® compatible Grouping Configuration The 2598 is shipped to allow four channels to be grouped and share a common field user power, thereby allowing a different user power supply voltage to be used by each grouping. Jumpers J2, J4, J5, and J6 come set in the “8 Common” selection from the factory and should not be altered for proper module operaton. This setting allows for 4 points per common operation. For example, Channels 1-4 will share a common user power and Channels 5-8 will share another common user power. In this example each group of four channels is isolated from the other group of four channels. Because each group of four is isolated, the user may also change the supply voltage for each group. So, in this example, Channels 1-4 could be 240VAC outputs and Channels 5-8 could be 120VAC outputs.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Modify Date : 2007:01:10 10:41:23-05:00 Create Date : 2007:01:10 10:41:19-05:00 Author : rpeck559 Subject : 06200335_011 Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:36f7d66e-8888-4523-ad1f-4ee3e6abfe8c Producer : Acrobat Distiller 6.0.1 (Windows) Keywords : Creator Tool : Adobe PageMaker 7.0 Document ID : uuid:316a93ce-3518-4edb-a315-fb67a778ff6f Format : application/pdf Title : 06200335_011 Creator : rpeck559 Description : 06200335_011EXIF Metadata provided by EXIF.tools