Lay In NEMA Type 12 Wireway

2014-10-22

: Pdf 88801-Attachment 1 88801-Attachment_1 Batch9 unilog

Open the PDF directly: View PDF PDF.
Page Count: 3

DownloadLay-In NEMA Type 12 Wireway
Open PDF In BrowserView PDF
L ay-In Wireway

Lay-In NEMA Type 12 Wireway

Bulletin

f10

NEMA Type 12 Nipple
Available in lengths of 1.00 in.
(25mm), 2.00 in. (51mm) and
3.00 in. (76mm).

Catalog Number

A x B x C in. (mm)

F22LN1

2.50 x 2.50 x 1.00
(64 x 64 x 25)
2.50 x 2.50 x 2.00
(64 x 64 x 51)
2.50 x 2.50 x 3.00
(64 x 64 x 76)
4.00 x 4.00 x 1.00
(102 x 102 x 25)
4.00 x 4.00 x 2.00
(102 x 102 x 51)
4.00 x 4.00 x 3.00
(102 x 102 x 76)
6.00 x 6.00 x 1.00
(152 x 152 x 25)
6.00 x 6.00 x 2.00
(152 x 152 x 51)
6.00 x 6.00 x 3.00
(152 x 152 x 76)

F22LN2
F22LN3
F44LN1
F44LN2
F44LN3
F66LN1
F66LN2
F66LN3

NEMA Type 12 Drop Hanger
Hangers are used to support a
wireway run. The drop hanger is
normally attached to an overhead
beam or ceiling.

Sealing Plates,
Type

Sealing Plates,
Qty.

Special

1

Special

1

Special

1

Special

1

Special

1

Special

1

Special

1

Special

1

Special

1

Catalog
Number

S
(in.)

S
(mm)

T
(in.)

T
(mm)

F22HD
F44HD
F66HD
F88HD

9.25
11.75
15.25
20.56

235
298
387
522

4.50
6.00
8.12
12.12

114
152
206
308

Wireway and
Trough

NEMA Type 12 Bracket Hanger
Hangers are used to support a
wireway run. The bracket hanger
can be used for wall, floor, or ceiling
installations.

Subject to change without notice	

Catalog
Number

P (in.)

P (mm)

R (in.)

R (mm)

U (in.)

U(mm)

F22HB
F44HB
F66HB
F88HB

4.62
6.12
8.25
10.25

117
155
210
260

3.62
3.62
3.62
3.62

92
92
92
92

4.38
5.88
7.88
11.25

111
149
200
286

PH 763 422 2211 • FX 763 422 2600 • hoffmanonline.com	

© 2008 Hoffman Enclosures Inc.

9

L ay-In Wireway

Lay-In NEMA Type 12 Wireway

Bulletin

f10

Application

Finish

Designed to protect electrical wiring from dust, dirt, oil, and water.
All straight sections and fittings are completely open on one side,
so wires and cables can be laid in along an entire wireway run. No
“pulling-through” of wires or cables is required with this design. A
complete selection of sections and fittings is available in five sizes:
2.50 in. x 2.50 in. (64mm x 64mm)
4.00 in. x 4.00 in. (102mm x 102mm)
6.00 in. x 6.00 in. (152mm x 152mm)
8.00 in. x 8.00 in. (203mm x 203mm)
12.00 in. x 6.00 in. (305mm x 152mm)

ANSI 61 gray polyester powder finish inside and out over
phosphatized surfaces. Box connector is gray ANSI 61 and “LSGQR”
sealing plate and quick-release latches are plated.

UL 870, File No. E27524
NEMA/EEMAC Type 12
JIC standards EGP-1-1967 and EMP-1-1967
CSA, File No. 42184, Type 1
IEC 60529, IP54

Accessories

Construction

Touch-Up Paint (ATPPY61)

Wireway and
Trough

•	 14 gauge steel covers and bodies
•	 10 gauge steel end flanges
•	 Seams continuously welded and ground smooth; no holes or
knockouts
•	 Smooth, rounded edges on all sections and fittings prevent damage
to insulation
•	 Heavy butt hinges and strong latches assure complete seal
between covers and bodies
•	 Quick-release cover latches permit immediate access to wireway
interior
•	 Oil-resistant gasket and adhesive
•	 Solid oil-resistant gasket positioned between flanges when sections
and fittings are bolted together
•	 Gasketed quick-release sealing plate provides complete sealing at
each joint

Subject to change without notice	

Industry Standards

Modification Services Program
You can customize this product to your unique requirements by
specifying from these options:
•	 Over 100 standard finish colors and textures
To order, contact your local Hoffman sales representative.
NOTE: For information about modifications outside the scope of the
Modification Services program, contact your Hoffman sales representative.

PH 763 422 2211 • FX 763 422 2600 • hoffmanonline.com	

© 2008 Hoffman Enclosures Inc.

1

L ay-In Wireway

Lay-In NEMA Type 12 Wireway

Bulletin

f10

Catalog Number Selection Matrix Lay-In NEMA Type 12 Wireway
Description

Sealing Platesa
Type
Qty.

6.00 inch (152mm) Straight Section

Flat

1

12.00 inch (305mm) Straight Section

Flat

1

24.00 inch (610mm) Straight Section

Flat

1

36.00 inch (914mm) Straight Section

Flat

1

48.00 inch (1219mm) Straight Section

Flat

1

60.00 inch (1524mm) Straight Section

Flat

1

120.00 inch (3048mm) Straight Section

Flat

1

Cutoff Fitting, Lay-In

Flat

1

Cutoff Fitting, Not Lay-In

90° Angle 1

Telescope Fitting, Lay-In

Special

1

Cross Fitting

Flat

3

90° Elbow, top opening

Flat

1

90° Elbow, inside opening

Flat

1

90° Elbow, outside opening

Flat

1

90° Elbow, outside top opening

Flat

2

45° Elbow, top opening

Flat

1

45° Elbow, inside opening

Flat

1

45° Elbow, outside opening

Flat

1

Tee Fitting, top opening

Flat

2

Tee Fitting, outside top opening

Flat

2

Junction Box

Flat

1

Closure Plate

90°

1

Box Connector

90°

1

Reducer 4.00 x 4.00 to 2.50 x 2.50 (102 x 102) to (64 x 64)

None

0

6.00 x 6.00 to 4.00 x 4.00 (152 x 152) to (102 x 102)

None

0

8.00 x 8.00 to 6.00 x 6.00 (203 x 203) to (152 x 152)

None

0

12.00 x 6.00 to 6.00 x 6.00 (305 x 152) to (152 x 152) None

0

12.00 x 6.00 to 4.00 x 4.00 (305 x 152) to (102 x 102) None

0

2.50 x 2.50
64 x 64
F22L06 c, d
F22L12c, d
F22L24c, d
F22L36 c, d
F22L48c, d
F22L60c, d
F22L120c, d
F22LXL
F22LX
F22LA
F22LCc, d
F22LE9Ac, d
F22LE9Bc, d
F22LE9Cc, d
—
F22LE45Ac, d
F22LE45Bc, d

4.00 x 4.00
102 x 102
F44L06 c, d
F44L12c, d
F44L24 c, d
F44L36 c, d
F44L48 c, d
F44L60c, d
F44L120c, d
F44LXL
F44LX
F44LA
F44LCc, d
F44LE9Ac, d
F44LE9Bc, d
F44LE9Cc, d
F44LE9ACd
F44LE45Ac, d
F44LE45Bc, d

6.00 x 6.00
152 x 152
F66L06 c, d
F66L12c, d
F66L24 c, d
F66L36 c, d
F66L48c, d
F66L60c, d
F66L120c, d
F66LXL
F66LX
F66LA
F66LCc, d
F66LE9Ac, d
F66LE9Bc, d
F66LE9Cc, d
F66LE9ACd
F66LE45Ac, d
F66LE45Bc, d

8.00 x 8.00
203 x 203
F88L06 c, d
F88L12c, d
F88L24 c, d
F88L36 c, d
F88L48c, d
F88L60c, d
F88L120c, d
F88LXL
F88LX
F88LA
F88LCc, d
F88LE9Ac, d
F88LE9Bc, d
F88LE9Cc, d
F88LE9ACd, d
F88LE45Ac, d
F88LE45Bc, d

12.00 x 6.00
305 x 152
F126L06 c, d
F126L12c, d
F126L24 c, d
F126L36 c, d
F126L48 c, d
F126L60c, d
F126L120c, d
F126LXL
F126LX
F126LA
F126LCc, d
F126LE9Ac, d
F126LE9Bc, d
F126LE9Cc, d
—
F126LE45Ac, d
—

F22LE45Cc, d
F22LTAc, d
F22LTCc, d
F22LJc, d
F22LP
F22LB
—
—
—
—
—
F22LN1c, d
F22LN2c, d
F22LN3c, d
F22HD
F22HB
F22LKTc, d
F22LKOKTc, d
F22LE9KTc, d
F22LE9KOKTc, d
—
—

F44LE45Cc, d
F44LTAc, d
F44LTCc, d
F44LJc, d
F44LP
F44LB
F44LRE22c, d
—
—
—
—
F44LN1c, d
F44LN2c, d
F44LN3c, d
F44HD
F44HB
F44LKTc, d
F44LKOKTc, d
F44LE9KTc, d
F44LE9KOKTc, d
F44BK60
F44B360

F66LE45Cc, d
F66LTAc, d
F66LTCc, d
F66LJc, d
F66LP
F66LB
—
F66LRE44 c, d
—
—
—
F66LN1c, d
F66LN2c, d
F66LN3c, d
F66HD
F66HB
F66LKTc, d
F66LKOKTc, d
F66LE9KTc, d
F66LE9KOKTc, d
F66BK60
F66B560

F88LE45Cc, d
F88LTAc, d
F88LTCc, d
F88LJc, d
F88LP
F88LB
—
—
F88LRE66 d
—
—
—
—
—
F88HD
F88HB
—
—
F88LE9KTc, d
F88LE9KOKTc, d
F88BK60
—

—
F126LTAc, d
—
—
F126LP
F126LB
—
—
—
F126LRE66 c, d
F126LRE44 c, d
—
—
—
—
—
—
—
—
—
F66BK60
—

1.00” (25mm) Nipple

Special

1

2.00” (51mm) Nipple

Special

1

3.00” (76mm) Nipple

Special

1

Drop Hanger

None

0

Bracket Hanger

None

0

Clockwise Transposition Section

Flat

1

Counterclockwise Transposition Section

Flat

1

90° Elbow, Clockwise Transposition

Flat

1

90° Elbow, Counterclockwise Transposition

Flat

1

Barrier Kit, bolt-on Each barrier 60.00” (1524mm)

None

0

Barrier, bracket-mountedb
Each barrier 60.00” (1524mm)

—

1 pkg.
(5 pcs.)

Barrier Brackets, 2 compartmentb

—

1 pkg. —
(5 pcs.)

F44BB2C

F66BB2C

—

—

Barrier Brackets, 3 compartmentb

—

1 pkg. —
(5 pcs.)

F44BB3C

F66BB3C

—

—

Flat Sealing Platea

—

—

F44LSGQR
F44LSAG

F66LSGQR
F66LSAG

F88LSGQR
F88LSAG

F126LSGQR
F126LSAG

90° Angle Sealing Platea
—
—
a
Each sealing plate also includes one gasket and one set of screws to join sections.
b
Package consists of five barriers or five brackets. Each barrier is 60 inches long.
c
Certified by Canadian Standards Association.
d
UL 870

F22LSGQR
F22LSAG

See Technical Information chapter or www.hoffmanonline.com for Wireway Fill Table

2

Subject to change without notice	

PH 763 422 2211 • FX 763 422 2600 • hoffmanonline.com	

© 2008 Hoffman Enclosures Inc.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Modify Date                     : 2009:06:22 09:42:33+05:30
Create Date                     : 2009:06:22 09:42:19+05:30
Title                           : Lay-In NEMA Type 12 Wireway
Author                          : Hoffman
Page Count                      : 3
EXIF Metadata provided by EXIF.tools

Navigation menu