T&B Fittings Catalog 93457

83012-Catalog- 1 83012-Catalog-_1 83012-Catalog-_1 786209 Batch2_1 unilog cesco-content

83012-Catalog 1 83012-Catalog_1 83012-Catalog_1 786209 Batch2_1 unilog cesco-content

2014-05-16

: Pdf 93457-Catalog 93457-Catalog 786209 Batch2_1 unilog

Open the PDF directly: View PDF PDF.
Page Count: 178

DownloadT&B Fittings Catalog  93457-Catalog
Open PDF In BrowserView PDF
412031.A01 FIT 3/12

3/20/03

3:02 PM

Page 1

A
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2
Tables and Specifications . . . . . . . . . . . . . . . . . . . . . . A3
Rigid Metal Conduit/Intermediate
Metal Conduit Fittings . . . . . . . . . . . . . . . . . . . A4-A38
Conduit Outlet Bodies . . . . . . . . . . . . . . . . . . . . A39-A40
Form 7, Form 8, and Red•Dot®
Conduit Outlet Bodies . . . . . . . . . . . . . . . . . . A41-A49
Mogul Conduit Outlet Bodies . . . . . . . . . . . . . . A50-A51
Aluminum Mogul Conduit Outlet Bodies . . . . . . A52-A53
FS/FD Cast Device Boxes and Covers. . . . . . . A54-A56
FS/FD Aluminum Device Boxes and Covers . . A57-A65
Conduit Expansion Coupling. . . . . . . . . . . . . . . A66-A67
Conduit Outlet Boxes
Explosion-Proof,
Dust-Ignition-Proof . . . . . . . . . . . . . . . . . . . . . A68-A69
Aluminum Conduit Outlet Boxes
Explosion-Proof, Dust-Ignition-Proof . . . . . . . A70-A79
Conduit Outlet Bodies
Explosion-Proof,
Dust-Ignition-Proof . . . . . . . . . . . . . . . . . . . . . A80-A81
Conduit Outlet Elbows
Explosion-Proof, Dust-Ignition-Proof . . . . . . . . . . . A82
RE, PLG, REC Reducers,
Plugs and Adapters
Explosion-Proof, Dust-Ignition-Proof . . . . . . . . . . . A83
Three-Piece Couplings
Explosion-Proof, Dust-Ignition-Proof . . . . . . . A84-A85
Aluminum Three-Piece Couplings
Explosion-Proof, Dust-Ignition-Proof . . . . . . . A86-A87
Elbows
Explosion-Proof, Dust-Ignition-Proof . . . . . . . . . . . A88
Flexible Couplings
Explosion-Proof, Dust-Ignition-Proof . . . . . . . . . . . A89
Sealing Fittings
Explosion-Proof,
Dust-Ignition-Proof . . . . . . . . . . . . . . . . . . . . . A90-A92
Aluminum Sealing Fittings
Explosion-Proof, Dust-Ignition-Proof . . . . . . . A93-A96
Kopr Shield™ Compound. . . . . . . . . . . . . . . . . . . . . . A97
Metal Clad Cable Termination Fittings . . . . . . A98-A108
Electrical Metallic Tubing (EMT) Fittings . . . . A109-A114
Liquidtight Flexible Metal
Conduit Fittings . . . . . . . . . . . . . . . . . . . . . A115-A131
XTRAFLEX® System – Conduit,
Tubing, Fittings for Nonmetallic
Liquidtight Conduit
Material – PVC. . . . . . . . . . . . . . . . . . . . . . A132-A139
Flexible Cords and Cable Fittings . . . . . . . . . A140-A151
Flexible Cords and Cable Fittings
Non-Metallic . . . . . . . . . . . . . . . . . . . . . . . A152-A153
WireMesh Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . A154
Non-Metallic Cable Glands. . . . . . . . . . . . . . . . . . . A155
Service Entrance Cable Fittings . . . . . . . . . . A156-A160
Armored Cable and Flexible Metal
Fittings Conduit . . . . . . . . . . . . . . . . . . . . . A161-A169
Non-Metallic Sheathed Cable Fittings. . . . . . A170-A175
Conduit Dimensional Data . . . . . . . . . . . . . . A176-A178

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 2

Introduction
Thomas & Betts … The Complete Product Line

A

®
T&B ® T&B
Fittings
Fittings

A

Since the turn of the century, Thomas & Betts has been a recognized
leader in electrical fittings. Industry standards such as Chase®
Nipples and Erickson® Couplings were introduced by Thomas &
Betts and are still registered trademarks. This leadership continues. Here’s why.
Innovative Designs
The real test of product design of electrical fittings lies in
two areas: Job-suited installation and life of the job reliability. Thomas & Betts Fittings provide both because
we listen. We listen to problems and suggestions
from the field. Most of the products in this section
result from the good suggestions of knowledgeable
electrical people. Many were customer specials to
solve particular installation and performance problems. You can benefit from their experience.
Approvals and Listings
Electrical raceways require accessory fittings that
provide the mechanical strength, ground continuity, and environmental integrity of the system. As
new raceways have been introduced, Thomas &
Betts engineers have designed fittings which
meet the requirements of the National Electrical
Code as well as the listing requirements of the
Underwriters’ Laboratories and the Canadian
Standards Association. You can use Thomas &
Betts Fittings with confidence.
High Performance Products
Quality and performance result when engineering
design skills are combined with the manufacturing
technologies required to produce them. The Thomas
& Betts Fittings in this section are produced from many
materials and by many manufacturing methods, each
carefully selected for its end use suitability. This combination gives you the reliable performance you expect from
Thomas & Betts Raceway Fittings.
Lower Installed Cost
It is a function of purchase cost, availability, installation advantage, and
performance. Lower installed cost comes in every carton of Thomas &
Betts Raceway Fittings.

A2

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 3

A
T&B ® Fittings

Tables and Specifications – Rigid Metal Conduit/Intermediate Metal Conduit Fittings
DURA-PLATE™ Finish – Corrosion Resistant Finish Protects
Fittings in Harsh Environments
Comparative Resistance to Salt Spray per ASTM B-117
500
450
DURA–PLATE™
Corrosion Resistant Fittings

HOURS OF SALT SPRAY

400
350

Mechanical
Galvanize

293

300
250
Standard
Zinc Plating

150
130

100
50

411

130
75

48

0
Indicates hours to white corrosion
Indicates hours to first apperance of red rust

DURA-PLATE™ Corrosion Resistant
Fittings have a T&B plating process
that provides excellent corrosion resistance on threaded steel and malleable
iron fittings for use in harsh environments.
DURA-PLATE™ Corrosion Resistant
Fittings utilize an electro-plating
process which insures a uniform thickness of protective material over the
entire part. Conventional hot dip coatings deposit an uncontrolled build-up
of material on the part, especially in
threaded areas. This excess build-up
must be removed to allow mating parts
to function.
The process of removing this build-up
in the threads in turn damages the
coating and compromises the effectiveness of the protection.
An additional drawback of hot dip
coating is the lower ductility of the
alloyed interface layer which is formed
during the hot dip process which can
cause spalling if the item is deformed
after coating.
In addition to the uniformity of the coat-

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

ing, the distinctive gold color of the
plating allows immediate recognition
that the part has been prepared for
exposure to harsh environments and
confirms the extra protection by visual
inspection.
DURA-PLATE™ Corrosion Resistant
Fittings have been subjected to salt
spray tests conducted according to
ASTM Specification B-117. The results
of Corrosion Resistant Fittings tests,
along with galvanized parts, appears
below:
Ordering Information
• Add the prefix “040-” to the standard
catalog number; for example a 5332
with DURA-PLATE™ Corrosion
Resistant Fittings protection would be
ordered as “040-5332”.
• Check for catalog numbers in stock.
• Allow 6-8 weeks for delivery, on nonstock items.
• Add 20% to price of standard item.
• Minimum order is standard package
quantity.

A3

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 4

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
Locknuts

140 Series
141AL Series

106 Series

Application
• To connect externally threaded conduit or connector to a threadless
opening in a box or enclosure.
• To effectively bond conduit or connector to box or enclosure.
Features
• Hardened Steel/Malleable
Iron/Copper free Aluminum
construction.
• Tightens without deformation.
• Locknuts specially designed to:
(i) Provide extended reach for
clamping on thin boxes and
enclosures.
(ii) Cut through protective coating on
box and enclosure thereby insuring ground continuity.
(iii) Permit tightening from outside.
(iv) Prevent loosening under vibration
• 106 Series provided with a hardened
cone point screw.
Standard Material
140 Series & 106 Series
c" thru 2" steel (hardened)
2d" thru 6" Malleable Iron
All screws steel
141AL Series
All copper-free aluminum
Standard Finish
All Steel and Malleable Iron locknuts
including
Electro Zinc Plated bonding screws
& Chromate Coated
All Aluminum locknuts . . . . degreased

A4

Range
⁄8" through 6" conduit (All threads
straight pipe [NPS]) (140 Series)
1
⁄2" through 4" conduit (106 Series &
141AL Series)
3

Listed/Certified by:
U.L. (U.L. File No. E-23018)
CSA [catalog numbers 108, 109 & 111.
All 140 Series except catalog number
140.] (LR-2884, LR-4484)
Conforms to:
U.L. 514B
CSA C22.2 No. 18
NEMA FB1
NFPA 70-1999 (ANSI)
Federal Specification replaced by
A-A-50553
Federal Standard H-28 (Threads)
“Case Hardened Locknuts”
Case hardened locknuts make fittings faster and easier to install. Case
hardened locknuts do not slip or turn
thereby protecting the biting edge.
Case hardened locknuts bite through
paint into the enclosure providing
excellent continuity of ground (typical
T&B/Thomas & Betts fitting with case
hardened locknuts successfully passed
minimum fault current of 10,000 amps
RMS). Case hardened locknuts when
assembled in the intended manner will
not vibrate loose thereby insuring excellent ground continuity.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 5

A
®
®

Locknuts
Cat. No.

(B) Thickness

Steel or malleable iron (steel thru 2") or
Aluminum 624.

Dimensions (in.)

Stl. or M.I.

Alum.

Size

A

B

139*
140*
141**
142**
143
144
145
146
147
148
149
150
151
152
153

–
–
141AL
142AL
143AL
144AL
145AL
146AL
147AL
148AL
149AL
150AL
151AL
152AL
153AL

b"
c"
d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
4d"
5"
6"

f
n
1ƒ
1c
1L
2q
2d
3
3l
4i
4m
5j
5n
6d
7f

!
!
q
i
$
$
$
r
u
u
v
v
w
w
x

* Hex shape
** Case hardened locknuts
Aluminum locknuts comply with federal standard of copper free aluminum; less than .5% copper.
Available with DURA-PLATE® Finish.
U.L. File E-23018
CSA File No. 2884
®
®

A

(B) Thickness

Steel or malleable iron (steel thru 2").
Use anywhere an ordinary locknut is installed
to insure positive bonding of conduit to box and
prevent loosening due to vibration. Also can be
used for Service Entrance applications in conformance with Code. T&B rigid conduit and
E.M.T. (thinwall) fittings comply with Federal
Specification WF 408c.

Bonding Locknuts
Dimensions (in.)

Cat.
No.

Size

A

B

106†
107†
108
109
110
111
112†
113†
114†
115†

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

1c
1e
1n
2q
2d
3
3u
4m
4C
5r

.125
.140
.170
.170
.170
.187
.375
.375
.438
.438

† Not CSA certified.
Available with DURA-PLATE ® Finish.
U.L. File No. E-3060
CSA File No. 638

®
®

Sealing Locknuts
A

Cat.
No.

B
C
Molded Santoprene Seal
Color: Blue

Provides positive seal against water and oil.
For use with rigid and intermediate metal
conduits, or fittings to provide watertight or
rain tight seal at all enclosures.

141SL
142SL
143SL
144SL
145SL
146SL

Dimensions (in.)
Size

A

B

C

d
f

1.140
1.420
1.770
2.281
2.598
3.175

a
q
™
™
™
i

b
s
s
j
s
∫

1
1b
1d
2

U.L. File No. E-23018
CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A5

T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 6

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
Bonding & Grounding Wedges
Application
To effectively bond terminating fitting
or conduit to a box or enclosure.

Series 3650

Series 3651

Features
• Sizes f" thru 6" equipped with an
additional bonding screw to install
bonding jumper where required.
• Can be added to an existing installation without disconnecting conductors.
Standard Material/Finish
d" size Steel/Electro Zinc Plated
f" thru 6" size
Bronze/Tin Plated

Range
d" thru 6" conduit
Listed/Certified by:
U.L File #E3060
CSA File #638
Conforms to:
U.L. 467
CSA C22.2 No. 41
NFPA-70 1999 (ANSI)
Federal Specification W-F-406

®

Grounding Wedges

Especially suited for grounding old work, but
equally convenient for new, grounding wedges
provide grounding without a jumper except in
concentric knockouts. When a jumper is
required, it fits under a set screw in the
grounding wedge.
Update existing installations to meet code
requirements for bonding (NEC Sect. 250-72e)
without disconnecting wiring. Use on new
wiring also.
1. Loosen bushing … position wedge.
2. Tighten bushing and bonding screw.

Cat.
No.

Size

3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3661
3662

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
5"
6"

U.L. File No. E-3060

®
®

Sealing Rings with Stainless Steel Retainer
B

A

Sealing Ring – Santoprene
Thermoplastic Rubber

These sealing rings provide a liquid tight, dust
tight, seal of fitting at enclosures.

Dimensions (in.)

Cat.
No.

Conduit
Size

A

B ± 1/ 64

5302
5303
5304
5305
5306
5307
5308
5309
5311

d"
f"
1"
1b"
1d"
2"
2d"
3"
4"

1™
1d
1f
2!
2&
2∂
3k
4Z
5s

f
n
1™
1d
1f
2%
2H
3∫
4∫

NEMA 3R, 4, 6 & 13
U.L. File No. E-13938
CSA File No. 2884

A6

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 7

A
Mounting
screw with
nylon locking
patch has a
cone point to
lock bushing
securely in
place.

Integral grounding
lug enhances
ground continuity.
Added ground
wire range taking
reduces inventory.
Accepts copper or
aluminum ground
wires.

Insulating nylon
surface is 150°C
rated and covers top
of bushing, including
lug corners.
Angle of lug
screw improves
accessibility
when securing
grounding wire.

Blackjack ® – Grounding Bushing
Innovative design makes installation
quicker, easier.
The Blackjack® Grounding Bushing
never has to be threaded onto a
conduit. It is simply placed in position
on either a threaded or non-threaded
rigid or IMC conduit, with the grounding lug in perfect position to accept the
grounding wire. Even in tight installations.
It’s as simple as one, two, three.
Compare the installation with conventional bushings that must be threaded
onto the conduit. In tight areas, you

Innovative design improves
performance.
The Blackjack® bushing provides
superior ground continuity.
Insulator surface
features a rounded
design to reduce
drag and prevent
abrasion during
wire pulling.

Cast “threads”
opposite the
mounting screw
tighten the fit during installation.

The design of the Blackjack bushing
has an integral, cast-on grounding lug
for better ground continuity. This
means that the Blackjack bushing
stands up to
intense loads.
Secure grip
forms lasting
bond.

may have to remove the grounding lug,
keep up with the loose parts, and then
reattach the lug. Then you still have to
twist and turn the bushing to get the
lug in position to accept the grounding
wire.
The Blackjack bushing does away with
these needless delays for good, making it the ideal grounding bushing. And
the only logical choice for small
spaces, corners, and multiple conduit
runs. And, because the grounding lug
is an integral part of the bushing, it is
designed not to fall off or get lost.

threaded and non-threaded rigid conduits. And the Blackjack bushing’s
nylon locking patch is designed to prevent the screw from loosening due to
vibration.
Reduce inventory.
Because the Blackjack Grounding
Bushing is designed for threaded and
non-threaded conduits, and the
ground lugs are designed to handle an
extended range, the number of parts in
inventory is reduced by up to twothirds without losing any application
coverage.

The Blackjack
bushing’s conepoint mounting
screw bites
securely into both

Blackjack ® – Conduit Grounding Bushing
Lug Screw:
14-4: Slotted
14-2/0: Slotted
6-4/0: Internal Hex Drive
Standard Material/Finish
Body: Malleable Iron or Aluminum
Mounting Screw: (1/ 2"-2") Stainless Steel,
(2 1/ 2"-6") Brass
Lug Screw: Stainless Steel
Finish: Zinc Plated or Mechanical Galvanized

Range
Conduit: d" thru 6" threaded or threadless rigid/IMC
Wire Range: #14 AWG to 4/0 AWG
CU/AL
Listed/Certified by:
U.L File #E3060
CSA File #LR2884
Conforms to:
U.L. 514B & U.L. 467
CSA C22.2 No. 18 &
CSA C22.2 No. 41

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A7

T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 8

Rigid and Intermediate Metal Conduit Fittings
Blackjack ™ Grounding Bushing technical information
Nylon Insulator (150oC)

Mounting Screw

Lug Screw
14-4: Slotted
14-2/0: Slotted
6-4/0: Internal hex drive

▼

▼
▼

▼
C
ØA

E

▼

▼

ØB
Throat I.D.

▼

Zinc
Plated
Malleable Iron
BG050-14-20
BG050-14-4
BG075-14-20
BG075-14-4
BG100-14-20
BG100-14-4
BG125-14-20
BG150-14-20
BG200-14-20
BG250-14-20
BG250-6-40
BG300-14-20
BG300-6-40
BG350-14-20
BG350-6-40
BG400-14-20
BG400-6-40
BG500-14-20
BG500-6-40
BG600-14-20
BG600-6-40

Aluminum
BGA050-14-20
BGA050-14-4
BGA075-14-20
BGA075-14-4
BGA100-14-20
BGA100-14-4
BGA125-14-20
BGA150-14-20
BGA200-14-20
BGA250-14-20
BGA250-6-40
BGA300-14-20
BGA300-6-40
BGA350-14-20
BGA350-6-40
BGA400-14-20
BGA400-6-40
BGA500-14-20
BGA500-6-40
BGA600-14-20
BGAT600-6-40

Conduit
Size

ØA
Max.

d"
d"
f"
f"
1"
1"
1b"
1d"
2"
2d"
2d"
3"
3"
3d"
3d"
4"
4"
5"
5"
6"
6"

1.251
1.251
1.533
1.533
1.783
1.783
2.220
2.470
2.830
3.418
3.418
4.042
4.042
4.542
4.542
5.042
5.042
6.136
6.136
7.199
7.199

▼

D

▼

▼

T&B ® Fittings

A

For Threaded & Threadless Rigid & IMC Conduit.

ØB
Min.
Throat I.D.
.569
.569
.772
.772
.993
.993
1.319
1.553
2.010
2.412
2.412
3.022
3.022
3.491
3.491
3.975
3.975
4.991
4.991
6.009
6.009

C
Max.

D
Max.

E
Max.

Wire
Range

1.181
1.027
1.221
1.030
1.181
1.027
1.181
1.181
1.181
1.181
1.524
1.181
1.524
1.181
1.524
1.181
1.524
1.181
1.524
1.181
1.524

2.134
1.940
2.414
2.168
2.581
2.368
2.987
3.236
3.766
4.341
4.526
4.966
5.139
5.467
5.639
5.966
6.139
7.045
7.207
8.087
8.409

.696
.696
.696
.696
.696
.696
.759
.696
.696
.978
.978
.978
.978
.978
.978
.978
.978
.978
.978
.978
.978

14-2/0
14-4
14-2/0
14-4
14-2/0
14-4
14-2/0
14-2/0
14-2/0
14-2/0
6-4/0
14-2/0
6-4/0
14-2/0
6-4/0
14-2/0
6-4/0
14-2/0
6-4/0
14-2/0
6-4/0

Suggested Specifications
Insulated grounding and bonding bushing
(Series BG050-BG600)
Where code requires bonding and grounding of single or multiple metal conduits, or positive bonding and grounding of metal conduit to the box, enclosure or auxiliary gutter, the end of the conduit shall be
equipped with an insulated metallic grounding and bonding bushing series BG050-14-20 as manufactured by Thomas & Betts.
Grounding and bonding bushings used shall be approved for the purpose and
(i) Shall be of malleable iron/steel/aluminum construction adequately protected against corrosion.
(ii) Bushing insulator shall be listed or certified for 150°C/302°F application with a flammability rating of 94V-O. Insulator must be positively locked in place.
Please consult factory for mechanically galvanized.

A8

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 9

A
T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings
Threaded Insulated Grounding Bushing
Application
• For quick installation of bonding
jumper to multiple metal conduits
(Rigid and IMC).
• Designed to bush conductors and
prevent insulation damage.

Wire
Clamping Screw
Lay-In
Lug

Insulator

Set Screw
(one)

Bushing
Casting

3870 Series

Features
• Ease of installation, lay in lug design.
• Cast malleable iron body designed to
lock insulator in place within body
reducing common assembly problem
resulting in dislodging of insulator.

• Insulator rated for 150°C/302°F
application.
Standard Material/Finish:
Body
Electro zinc plated
Lay in lug Aluminum/tin plated
Insulator Thermoplastic
150°C/302°F
Application with 94V-0
flammability

®
®

Threaded Insulated Grounding Bushing
Cat.
No.
3870-TB
3861
3871-TB
3862
3872
3882
3873
3883
3874
3884
3875
3889
3876
3886
3993
3877
3887
3994
3878
3863
3995
3879
3864
3996
3880
3865
3998
3881
3866
3999

Conduit
Size

Bushing
Dia.

Throat
Dia.

Lug
Length

Swing
Radius

Bushing
Height

Wire
Range
AWG
CU/AL

d
d
f
f

1.125
1.125
1.420
1.420
1.770
1.770
2.190
2.190
2.468
2.468
3.031
3.031
3.516
3.516
3.516
4.234
4.234
4.234
4.781
4.781
4.781
5.328
5.328
5.328
6.328
6.328
6.328
7.406
7.406
7.406

.560
.560
.742
.742
.944
.944
1.242
1.242
1.449
1.449
1.860
1.860
2.222
2.222
2.222
2.761
2.761
2.761
3.193
3.193
3.193
3.623
3.623
3.623
4.542
4.542
4.542
5.458
5.458
5.458

1.310
1.675
1.310
1.675
1.310
1.675
1.310
1.675
1.310
1.675
1.310
1.675
1.310
1.675
2.230
1.310
1.675
2.230
1.310
1.675
2.230
1.310
1.675
2.230
1.310
1.675
2.230
1.310
1.675
2.230

1.212
1.402
1.360
1.550
1.535
1.725
1.745
1.935
1.884
2.074
2.165
2.355
2.408
2.598
2.928
2.767
2.957
3.287
3.040
3.230
3.560
3.314
3.504
3.834
3.814
4.000
4.334
4.353
4.543
4.875

.657
.657
.660
.660
.735
.735
.735
.735
.770
.770
.770
.770
.940
.940
.940
.975
.975
.975
.975
.975
.975
.980
.980
.980
.985
.985
.985
1.200
1.200
1.200

14-4
8-2/0
14-4
8-2/0
14-4
8-2/0
14-4
8-2/0
14-4
8-2/0
14-4
8-2/0
14-4
8-2/0
6-4/0
14-4
8-2/0
6-4/0
14-4
8-2/0
6-4/0
14-4
8-2/0
6-4/0
14-4
8-2/0
6-4/0
14-4
8-2/0
6-4/0

1
1
1b
1b
1d
1d
2
2
2d
2d
2d
3
3
3
3d
3d
3d
4
4
4
5
5
5
6
6
6

Temperature rating 150°C.
Meets Coast Guard Regulation CG293
Available with DURA-PLATE® Finish.
For mechanically galvanized iron, add suffix-MG.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A9

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 10

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
Insulated Throat Fittings

Nylon insulated
metallic bushings

Steel or malleable iron (Steel thru 1 1⁄ 2")
The National Electric Code paragraph 373-6C
calls for protection of ungrounded conductors
by means of smoothly rounded insulating surfaces at the entrance to raceways, pull boxes,
junction boxes, etc. T&B insulated throat fittings, recognizable by the distinctive trademarked blue insulating liner in the throat,
meet and surpass this Code requirement. In
addition, T&B insulated fittings also reduce
wire pulling effort by as much as 50%.
Temperature rating 105°C.

Dimensions (in.)

Cat.
No.

Alum.

Size

A

B

1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232†
586
587

1222AL
1223AL
1224AL
1225AL
1226AL
1227AL
1228AL
1229AL
1230AL
1231AL
1232AL†
586AL
587AL

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
4d"
5"
6"

1o
1s
1x
1n
2i
2L
3i
3B
4k
4g
–
5O
7i

S
M
X
y
z
g
O
n
1h
1p
–
1s
1X

† Not CSA Certified
Catalog series 1222 thru 1232, 586 and 587 are available in aluminum. Add suffix AL to Cat. No.
The aluminum series are not CSA certified.
®
®

Metallic Bushings
Cat. No.

Dimension (in.)
Alum.

Size

A

122AL
123AL*
124AL**
125AL
126AL
127AL
128AL
129AL
130AL
131AL
–
133AL
134AL

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
4d"
5"
6"

1o
1b
1l
1C
2q
2y
3i
3B
4c
4n
5k
6
7b

Stl. or M.I.

Aluminum, steel or malleable iron (steel
thru 1 1⁄ 2").
Smoothly rounded shoulder covers end of conduit: broad flange covers knockout hole. High
ribs make tightening easy with fingers or with
wrench. 1⁄ 2" - 1 1⁄ 2" size, formed in steel, have
extra smooth shoulders. Locknut-type base
gives improved bonding and resists loosening
under conditions of vibration.

122
123
124
125-TB
126
127
128
129
130-TB
131-TB
132-TB
133-TB
134-TB

B
u
k
d
l
x
e
f
m
n
1
1Z
1i
1b

* Not U.L. Listed or CSA Certified
** Not CSA Certified
Available with DURA-PLATE® Finish.
U.L. File No. E-23018
CSA File No. 2884

®
®

Plastic Insulating Bushings

All Plastic
Insulating
Bushings

Impact resistant plastic insulation. These
bushings have ribs for gripping when
installing. Perfect threads for easy thread
on. U.L. Listed 105°C.

Dimensions (in.)

Cat.
No.

Size

A

222-TB
223-TB
224
225-TB
226
227
228-TB
229-TB
230-TB
231
232
233
234

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
4d"
5"
6"

1h
1s
1l
1C
2r
2A
3c
4h
4e
5a
5L
6j
7k

B
c
u
l
l
l
e
f
f
g
g
1
1
1

Flame retardant. U.L. Rated 94V-1.

A10

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 11

A
T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings
Insulating Bushing
(For Threadless Rigid Conduit and Intermediate Metal Conduit)

TRIB50 Series

1. Cut conduit end squarely. Remove sharp
edges and burrs on inside and outside diameters by reaming or filing.
2. Slip the pop-on bushing over the end of the
conduit.

Standard Finish

Application
• When assembled to the end of a
threadless conduit, provides a well
rounded insulating surface over
which conductors may be pulled or
on which conductors may bear while
in service.

As molded.
Range
d" through 4" conduit
Listed by:
U.L. (U.L. File No. E-13938)
CSA (LR-2884, LR-4484)

Features
• Designed to be popped onto, and
bush, conduit end.
• Fast, easy installation without screws.
• High impact thermoplastic
construction.

Conforms to:
U.L. 514B
NFPA 70-1999 (ANSI)

Standard Material
High impact thermoplastic listed for
105°C (221°F) application.
Flammability Classification 94 V-1.
3. Using the flat surface of any standard utility
tool such as an electricians pliers (or a hammer with a block of wood for the larger
sizes), strike the bushing on its top surface
using a series of light blows until the end of
the conduit rests against the bushing throat
& conduit stop.
®
®

Insulated Metallic Bushing

Pop-on Bushing

Threadless Rigid (and IMC) Insulating
Bushings.

Dimensions (in.)

Cat.
No.

Size

A

TRIB-50
TRIB-75
TRIB-100
TRIB-125
TRIB-150
TRIB-200
TRIB-250
TRIB-300
TRIB-350
TRIB-400

d"
f"
1"
1b
1d"
2"
2d"
3"
3d"
4"

x
A

B
1s
1ç
1d
1e
1y
1m
2
2r
2j
2u

1
1j
1w
1O
2R
2∂
3c
3B

C
1h
1b
1l
1∂
2™
2L
3b
3C
4S
5

I.M.C. sizes d" thru 4"
U.L. Rated flame retardant 94V-1.
U.L. File No. E-13938
CSA File No. 2884
A

B

C

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A11

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 12

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
Knockout Bushings
Application
• To bush knockout openings in metal
boxes or enclosures.

3210 Series

Features
• One piece construction designed to
snap in place.
• High impact strength self extinguishing non-dripping (per U.L. 94) thermoplastic construction.
Standard Material
Thermoplastic rated for 105°C (221°F)
application.
Standard Finish
As molded.

Range
.875" through 2.469" nominal diameter
knockout opening (d" through 2" trade
size knockouts).
Wall thickness of box or enclosure
.095" max. up to 1" trade size.
.140" max. 1b" through 2" trade size.
Listed/Certified by:
U.L. (U.L. File No. E-3803)
CSA (LR-589, LR-4484)
Conforms to:
U.L. 514B
CSA C22.2 No. 18
NFPA 70-1999 (ANSI)

®
®

Knockout Bushing
One-piece knockout bushing quickly snaps into
outlet box, switch box, or other enclosure left
vacant by wiring modifications or maintenance
changes. Provides smooth, rounded insulation
surface for easy wire pulling. Easily installed
by hand, they are available to fit 1⁄ 2" through 2"
knockouts. U.L. Listed 105°C. High impact
thermoplastic.

Cat.
No.

For use in
KO Size*

Dimension (in.)

3210
3211
3212
3213
3214
3215

.875
1.109
1.375
1.734
1.984
2.469

.360
.360
.360
.400
.520
.520

B

* Per U.L. and NEMA standards. Refer to “KNOCKOUT” table on page A14.
Oxygen index >28°
U.L. 94V-1
U.L. File No. E-3803
CSA File No. 589

A12

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 13

A
®
®

Capped Bushings
Dimension (in.)

Cat.
No.

Size

A

B

1460
1461
1462
1463
1464
1465

d"
f"
1"
1b"
1d"
2"

1o
1b
1l
1C
2q
2y

u
k
d
l
x
e

U.L. File No. E-23018
CSA File No. 2884

Makes a workmanlike seal against grit, plaster,
and mischief. Removable with pliers. As shown
1
⁄ 2" through 11⁄ 2" in steel: 11⁄ 2" and 2" in malleable iron.

®
®

INSULINER® Sleeves

Slip over wires – insert
into bushing – snaps
into place

High dielectric nylon, 105°C.
An insuliner sleeve snapped into a regular
bushing makes a U.L. Listed insulated bushing.
For standard rigid conduit, E.M.T. (thinwall
conduit) or any standard bushed outlet.
Especially suitable for use with flexible metallic conduit.
Converts ordinary bushing to code approved
insulated bushing without disturbing wiring.

Dimension (in.)

Cat.
No.

Size

A

B

422
423
424
425
426
427
428
429
430
431
433
434

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
5"
6"

e
L
g

.025
.025
.025
.030
.030
.030
.040
.040
.055
.055
.070
.070

1
1
1a
1b
1d
1A
2o
2d
2d

Oxygen index >28°
U.L. File No. E-23018
CSA File No. 589

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A13

T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings

412031.A01 FIT 3/12

3/20/03

3:03 PM

Page 14

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
Knockout Plugs
Application
• To plug unused knockout openings in
a box or enclosure.

1451 Series

Features
• One piece construction designed to
snap in place.
• High impact strength self-extinguishing non-dripping (per U.L.-94) thermoplastic construction.

Range
.875" through 2.469" Nominal Diameter
Knockout opening (d" through 2" trade
size knockouts).
Wall thickness of box or enclosure
.095" max. up to 1" trade size
.140" max. through 2" trade size.
Listed/Certified by:

Standard Material

U.L. (U.L. FILE No. E13938)
CSA (LR589)

Thermoplastic rated for 105°C (221°F)
application.

Conforms to:

Standard Finish

U.L. 514B
NFPA 70-1999 (ANSI)

As molded.
®
®

Knock-out Plugs

105°C rated by U.L. Made from flame retardant,
non-dripping thermoplastic.

Dimensions (in.)

Cat.
No.

Size

A

B

1451
1452
1453
1454
1455
1456

d"
f"
1"
1b"
1d"
2"

1.060
1.300
1.590
1.860
2.240
2.740

.400
.400
.400
.450
.570
.570

Wall thickness of electrical box .095 max.
Meets Coast Guard Regulation CB293.
U.L. File No. E-13938
CSA File No. 4484

A14

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 15

A
T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings
Plug, Conduit, Connectors (Push Penny ® Plugs)
Application
• To plug open end of conduit or connector in order to prevent ingress of
trash, dirt or moisture during construction and remodeling.

Standard Material

Features
• Wide range of application; can be
used with rigid metal conduit, intermediate metal conduit, electrical
metallic tubing, all connnectors and
all bushings.
• Designed to stand up to normal
handling and is functionally unaffected
by moisture.

Listed/Certified by:

Polyethylene
Standard Finish
As molded
CSA (LR2884, LR4484)
Conforms to:
U.L. 514B
CSA C22.2 No. 18
NFPA 70-1999 (ANSI)
NEMA FB1

Push-Penny® Plugs

Economically seal out grout and plaster from
any fitting or raceway conforming to CSA
dimensional tolerances. Made of flexible plastic, they push into place and are held fast by
pressure against internal surface of fitting or
raceway. Eliminates need for separate capped
bushing or steel penny and bushing.

Cat.
No.

Size

1470
1471
1472
1473
1474
1475
1476*
1477*
1478*
1479*

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

* Not CSA Certified
CSA File No. 2884
UL not applicable

Pennies – Steel

A penny under a bushing will seal the end of
the conduit during construction. Made to fit any
bushing. Completely salvageable.

Cat.
No.

Size

815-TB
816
817
818
819
820
821
822
824
823

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

U.L. not applicable
CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A15

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 16

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
Nipple (CHASE ® Nipple)

1942 Series
842AL Series
(Non Insulated)

Application
• To effectively bush factory or fieldpunched, cut, or drilled holes in
metal boxes or enclosures.
• To couple boxes back-to-back.
Features
• Rugged construction.
• Insulator curled over to:
Bush conductors entering/leaving
at any angle.
Reduce wire pull effort.
Protect threads against damage
in handling.
Standard Material
1942 Series
Body.........................................d" Steel
f" through 6" Malleable Iron
Insulator ......................................Nylon
842AL Series
All Copper free Aluminum

A16

Standard Finish
1942 Series.............Electro Zinc Plated
& Chromate Coated
842AL Series.......................Degreased
Range
1942 & 842AL Series
d" through 6"
All hub threads straight pipe (NPS)
Listed/Certified by:
U.L. [All except for Catalog No. 842AL,
844AL & 845AL]
(U.L. File No. E-23018)
CSA (LR-2884, LR-4484)
Conforms to:
U.L. 514B
CSA C22.2 No. 18
Federal Specification W-F-408
NFPA 70-1999 (ANSI)
NEMA FB1
Federal Standard H-28 (Threads)

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 17

A
®
®

CHASE® Nipples
Cat. No.
Stl. or M.I.

Steel or malleable iron or aluminum.

841TB
842TB
843TB
844
845
846
847
848
849
850
851
853
854

Dimensions (in.)
Alum.

Size

A

B

–
842ALTB†
843ALTB
844AL†
845AL†
846AL
847AL
848AL
849AL
850AL
851AL
853AL
854AL

c"
d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
5"
6"

n
1a
1c
1L
2
2c
2n
3l
4c
5a
5
6d
7d

k
u
x
y
A
m
O
1h
1b
1j
1j
1j
1c

† Not UL Listed
Available with DURA-PLATE® Finish.
U.L. File No. E-23018
CSA File No. 2884

®
®

CHASE® Nipples – Nylon Insulated

Steel or malleable iron or aluminum.

Dimensions (in.)

Cat.
No.

Size

A

B

C

1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1953
1954

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
5"
6"

1p
1c
1L
2o
2c
2n
3l
4c
5a
5a
6c
7e

k
w
y
A
m
O
1h
1i
1j
1j
1j
1c

l
z
g
1o
1p
1X
1k
1x
1A
1m
1m
1g

U.L. File No. E-23018
CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A17

T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 18

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
(A)

Threaded Hubs (Bullet® Hubs)

Predetermined
Compression
(B)

Application
• To connect threaded metal conduit
(ferrous rigid/non-ferrous rigid/PVC
coated/or intermediate metal) to a
threadless opening in a box or enclosure in outdoors or indoor location
exposed to continuous or intermittent
moisture.
• To positively bond conduit to box or
enclosure.

(C)

(E)

(D)

370 Series
370AL Series

(G)

(A)
(F)

(B)
(G)
(C)
(D)
(E)

485 Series

A18

(For Threaded Rigid Metal Conduit/IMC/PVC Coated Rigid Metal Conduit)

Features
• Rugged steel/malleable iron/copper
free aluminum construction.
• Tapered internal threads for watertight/dust tight union (A).
• Threads relieved to prevent bottoming of conduit ensuring sound
assembly (B).
• Recessed sealing ring at box end.
Sealing ring captivated (C).
• Hardened steel/malleable iron/copper free aluminum locknuts designed
to provide high quality ground continuity; extended reach of locknut permits clamping on thin boxes and
enclosures (D).
• Insulated throat, insulates conductors,
prevents abrasion and thinning of
conductor insulation, reduces wire
pull effort (E).
• Suitable for hazardous location use
per following:
(i) Class I Division 2, Class II
Division 1 & 2, Class III Division
1 & 2 per N.E.C. 501-4 (b); 502-4
(a) and 503-3 (a).

(ii) Class II Groups E, F, G, & Class
III locations per CEC 18-202; 18252; 18-302; 18-352.
• PVC coated 485 Series
(i) Protects connector from
extremely corrosive surroundings
without affecting integrity of electrical grounding path (F).
(ii) Provided with overlapping sleeve
for additional seal (G).
National Electrical Code states that,
“Where practicable, dissimilar metals
in contact anywhere in the system shall
be avoided to eliminate the possibility
of galvanic action”, the only exceptions
Aluminum fittings and enclosures, are
permitted to be used with steel conduit.
Joint Industrial Council (JIC)
Electrical Standards also forbid dissimilar metals in contact for the same reason and require that the fittings for
metal conduit be of malleable iron or
ductile iron and have impact strength
comparable to that of the conduit.
“Copper Free Aluminum”
Copper free aluminum castings for
fittings have a maximum of 0.4% copper. The most detrimental effect of
higher percentage of copper on aluminum base alloy is its decrease in
corrosion resistance.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 19

A
T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings
Threaded Hubs (Bullet ® Hubs) – (Continued)
(For Threaded Rigid Metal Conduit/IMC/PVC Coated Rigid Metal Conduit)

Standard Material
370-485 Series
Body

⁄2" thru 1" Steel
11⁄4" thru 6" Malleable Iron
1
⁄2" thru 2" Steel (hardened)
21⁄2" thru 6" Malleable Iron
Steel (hardened)
Buna N
Nylon
PVC
1

Locknut
Screws
‘O’ Ring
Insulator
Coating

370AL
All Copper-Free Aluminum
⁄2" thru 2" Steel (hardened)
21⁄2" thru 4" Copper Free Aluminum

1

Standard Finish
370 Series
Hub
Locknuts
Screws

370AL Series

485 Series

Electro Zinc Plated
As Cast
PVC – Outside. Electro Zinc
Chromate Coated
Plated Chromate Coated Inside
All Ferrous Locknuts Electro Zinc Plated and Chromate Coated
All Electro Zinc Plated & Chromate Coated

Range
370 Series ..........................d" thru 6" Conduit
370AL & 485 Series ...........d" thru 4" Conduit
All hub threads – straight pipe
All female threads – taper pipe
(NPT)
Listed/Certified by:
U.L. (U.L. File No: E-23018)
CSA (LR-637, LR-23086)
Conforms To:
U.L. 514B
CSA C22.2 No. 18
NFPA 70-1999
NEMA FB-1
JIC EGP1; JIC EMP 1
Federal Specification W-F-408
Federal Standard H-28 (Threads)

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A19

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 20

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
®
®

Steel/Malleable Iron and Aluminum Hub Connectors*†
Cat. No.

Nylon insulated
Aluminum, steel, or malleable iron (steel
through 1"). With Neoprene “O” Ring provides
a watertight threaded hub on enclosures. U.L.
Listed 105°C.

Dimensions (in.)

Stl. or M.I.

Alum.**

Size

A

B

C

370
371
372
373
374
375
376
377
378
379
381
382

370AL
371AL
372AL
373AL
374AL
375AL
376AL
377AL
378AL
379AL
–
–

d"
f
1"
1a"
1d"
2"
2d"
3"
3d"
4"
5"
6"

1c
1e
2p
2l
3p
3e
4a
5
5l
6i
8
9i

1b
1b
1c
1e
1e
1e
1g
2d
2d
2d
3a
3a

f
f
g

Wall
Thk.
(max.)
j
j
j
j
j
j
c
d
d
d
d
d

1
1
1
1a
1d
1d
1d

* Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 2; Class III, Div. 1 and 2 where general purpose equipment is
specifically permitted per NEC Section 500-2(a).
** Aluminum not available with insulated throat.
† U.L. Listed rain tight and CSA Certified watertight and dust tight
Available with DURA-PLATE® Finish.
U.L. File No. E-23018
For Stl.: CSA File No. 2284
For AL.: CSA File No. 0637

PVC Coated Hub for Rigid Conduit

Steel or malleable iron (steel thru 11⁄ 4").

LOCKNUT
NFS THREAD

C

B

PLASTIC
COATING

A

Dimensions (in.)

Cat.
No.

Conduit Size

A

485
486
487
488
489
490
491
492
493
494

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

1Q
1x
1B
2v
2C
3c
3B
4y
5!
5f

B

C

2a
2a
2f
3c
3e
3f
4
4e
4m
4l

1g
2a
2c
3a
3d
4
4d
5e
5g
6k

Suitable for hazardous locations use per Class I, Div. 2; Class II, Div. 1 & 2; Class III, Div. 1 & 2 NEC 501-4(b); 502-4(a) (2); 503-3(a)
where general purpose equipment is specifically permitted per NEC Section 500-2(a).

INSULATOR
SEALING RING

A20

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 21

A
T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings
Spacing Chart for Bullet® Hubs
Center to Center Spacing

Min. Space from
Center of
Bullet® Hub to
4
Wall of Box

Conduit Sizes
3

1

⁄2

1

1

1

1

⁄4

1

1 ⁄4

1 ⁄2

2

2 ⁄2

3

3 ⁄2

KO
Diameters
(min.)

1

1k

1e

1f

2a

2c

2e

2g

3j

3d

3g

f

g

3

–

1f

1g

2b

2d

2f

3

3d

3f

4a

g

1a

⁄2
⁄4

1

–

–

2

2c

2e

2g

3a

3e

3g

4b

1a

1c

11⁄ 4

–

–

–

2L

2n

3b

3d

4

4b

4d

1c

1f

1

1 ⁄2

–

–

–

–

3a

3d

3f

4a

4c

4f

1e

2

2

–

–

–

–

–

3f

4

4d

4f

5

1g

2d

21⁄ 2

–

–

–

–

–

–

4b

4f

5

5c

2a

3

3

–

–

–

–

–

–

–

5a

5c

5f

2e

3e

31⁄ 2

–

–

–

–

–

–

–

–

5e

6

2g

4a

4

–

–

–

–

–

–

–

–

–

6b

3b

4e

®

BULLET® Hub Connectors – Nylon Insulated
Cat. No.

Size
(in.)

401
402
403
404-TB
405
406-TB
407
408
409
410-TB

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

Packaging
Description

Steel or malleable iron (steel through
1 inch). Used with a neoprene “O” ring
to provide a watertight* threaded hub
on enclosures. Supplied with 106 series
bonding locknut. Temperature rating: 105°C.

Carton

Std.

Wt.
per 100

25
25
5
5
2
1
1
1
–
–

100
50
25
25
10
5
5
5
1
1

20
26
44
75
100
138
200
375
425
500

*CSA LR2884. Certified watertight and dust tight.

Spacing Chart for Bullet® Sealing Hubs
Center to Center Spacing
Conduit Sizes
1

⁄2

3

⁄4

1

11⁄ 4

11⁄ 2

2

21⁄ 2

3

31⁄ 2

4

5

6

Min. Space from
Center of
Bullet® Hub to
Wall of Box

KO
Diameters
(min.)

1

1k

1e

1f

2a

2c

2e

2g

3j

3d

3g

4g

5j

f

g

3

⁄4

–

1f

1g

2b

2d

2f

3

3d

3f

4a

4m

5d

g

1a

1

–

–

2

2c

2e

2g

3a

3e

3g

4b

4n

5L

1a

1c

11⁄ 4

–

–

–

2L

2n

3b

3d

4

4b

4d

5j

5f

1c

1f

⁄2

1

1 ⁄2

–

–

–

–

3a

3d

3f

4a

4c

4f

7k

6i

1e

2

2

–

–

–

–

–

3f

4

4d

4f

5

5f

6d

1g

2d

21⁄ 2

–

–

–

–

–

–

4b

4f

5

5c

6

6f

2a

3

3

–

–

–

–

–

–

–

5a

5c

5f

6c

7a

2e

3e

31⁄ 2

–

–

–

–

–

–

–

–

5e

6

6f

7d

2g

4a

4

–

–

–

–

–

–

–

–

–

6b

7a

7g

3b

4e

5

–

–

–

–

–

–

–

–

–

–

8

8f

4

5d

6

–

–

–

–

–

–

–

–

–

–

8f

9d

4f

6d

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A21

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 22

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
2 Locknut Design with peripheral
slots and a hexagonal/angled spline
spaced every 30° enables easy
application of torque with wrench or
hammer and screwdriver. (See
Figures 2 & 3)

Never before has a single hub fit like this
one. Designed for unequalled performance. The innovative engineering of
the T&B® Hub will, quite simply, raise
your performance expectations for
threaded hubs.

4

5

1

3

2

6

Fig. 2

Fig. 3

3 Sharper and Deeper Teeth on locknut and body designed for a more
penetrating bite for improved bonding to the enclosure.
4 Hexagonal/Splined Body Design
for fast, easy installation with wrench
or hammer and screwdriver.
5 Precision Machined Tapered
Threads designed to create watertight union.
6 Insulated Throat molded from 105°
C rated thermoplastic with a flammability rating of 94 V-O.

1 Sealing Ring And Groove with innovative profile outperforms standard
‘O’ ring design. Sealing ring is captivated in place before installation and
resists buckling or slipping during
installation. The seal groove is
designed for optimum compression
of the sealing ring. The sealing ring is
designed to provide a complete 360°
seal, even when the conduit is not
perpendicular with the enclosure.
(See Figure 1)

®

Fig. 1

®

T&B Hub
A
Cat.
No.
H050-TB
H075-TB
H100-TB
H125-TB
H150-TB
H200-TB
H250-TB
H300-TB
H350-TB
H400-TB
H500-TB
H600-TB

Throat Dia. E

Material –

B
D

C

A

A22

Trade
Size

Dia.

d
f
1
1b
1d
2
2d
3
3d
4
5
6

1k
1y
2
2c
2f
3b
3f
4c
5
5d
6g
7L

B

C

D
Max. Panel
Thickness

1l
1x
1m
1g
1g
1n
2l
2y
2z
2z
3o
3q

g
C
1h
1h
1h
1q
1l
1x
1e
1e
1n
2

i
i
b
b
b
b
b
b
b
b
b
j

E
Throat
Dia.
x
A
1
1j
1w
1O
2u
2O
3u
3g
4n
6

Hub and Locknut:
Insulating Throat:

zinc or copper free aluminum
thermoplastic temp. rating – 105°C
Flammability Rating: – 94V-0
Sealing Ring
Nitrile (BUNA “N”)
For Aluminum Hubs add suffix A (i.e. H050A). For Chrome Plated Hubs add suffix CP (i.e. H050CP). For 316 Stainless Steel Hubs add
suffix GRSST (i.e. H050GRSST). (d" through 2" only.) Meets NEMA sealing requirements for NEMA 3R, 4 & 13 enclosures.
U.L. Listed and CSA Certified. CSA Certified for hazardous locations Class II Groups E.F.G. Class III.
U.L. File No. E-23018
CSA File No. 4484
Chrome Plated Hubs (suffix-“CP”) are rated NEMA 4X.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 23

A
T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings
T&B Grounding Hub
Cat.
No.
H050GR-TB
H075GR-TB
H100GR-TB
H125GR-TB
H150GR-TB
H200GR-TB
H250GR-TB
H300GR-TB
H350GR-TB
H400GR-TB
H500GR-TB
H600GR-TB

Throat Dia.

Material –

E

C

B
A

A
Dia.

Trade
Size
d
f

1k
1y
2
2c
2f
3b
3f
4c
5
5d
6g
7L

1
1b
1d
2
2d
3
3d
4
5
6

B

C

D
Max. Panel
Thickness

1l
1x
1m
1g
1g
1n
2l
2y
2z
2z
3o
3q

g
C
1h
1h
1h
1q
1l
1x
1e
1e
1n
2

i
i
b
b
b
b
b
b
b
b
b
j

E
Throat
Dia.
x
A
1
1j
1w
1O
2u
2O
3u
3g
4n
6

Hub and Locknut:
Insulating Throat:

zinc or copper free aluminum
thermoplastic temp. rating – 105°C
Flammability Rating: – 94V-0
Sealing Ring
Nitrile (BUNA “N”)
For Aluminum Hubs add suffix A (i.e. H050A). For Chrome Plated Hubs add suffix CP (i.e. H050CP). For 316 Stainless Steel Hubs add
suffix GRSST (i.e. H050GRSST). (d" through 2" only.) Meets NEMA sealing requirements for NEMA 3R, 4 & 13 enclosures.
U.L. Listed and CSA Certified. CSA Certified for hazardous locations Class II Groups E.F.G. Class III.
U.L. File No. E-23018
CSA File No. 4484
Chrome Plated Hubs (suffix-“CP”) are rated NEMA 4X.
®
®

T&B Grounding and Bonding Locknut

A

Cat.
No.

Trade
Size

A
Dia.

B
Height

Ground
Screw

Max. Conductor
Size

L050GR
L075GR
L100GR
L125GR
L150GR
L200GR
L250GR
L300GR
L350GR
L400GR
L500GR
L600GR

d
f

1d
1L
2
2c
2f
3b
3f
4c
5
5d
6e
7L

u
u
u
v
v
v
L
z
z
z
z
z

#10-32 x b"
#10-32 x b"
#10-32 x b"
b-20 x b"
b-20 x j"
b-20 x j"
b-20 x j"
b-20 x j"
b-20 x j"
b-20 x j"
c-16 x c"
c-16 x c"

#10
#10
#10
#10
#8
#8
#6
#6
#6
#4
#2
#1

1
1b
1d
2
2d
3
3d
4
5
6

Material – Locknut: zinc or copper free aluminum
U.L. File No. E-3060
For Aluminum Locknuts add suffix A. (i.e. L050GRA)
CSA File No. 4484
For Chrome Plated Locknuts add suffix CP. (i.e. L050CP). For 316 Stainless Steel Locknuts add suffix SST (d" through 2" only.)

T&B Hub Centerline Spacing Chart
Conduit
Trade Size
1

B

Grounding Locknut for Hubs

⁄ 2"
3
⁄ 4"

1"
11⁄ 4"
11⁄ 2"
2"
21⁄ 2"
3"
31⁄ 2"
4"
5"
6"
Nearest Obstruction
to Center of Hub

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

1

⁄ 2"

1l
1H
1B
2o
2r
2v
2z
3o
3X
3x
4s
4L
B

3

⁄ 4"

1"

11⁄ 4"

11⁄ 2"

2"

21⁄ 2"

3"

31⁄ 2"

4"

5"

6"

1A
1V
2!
2Q
2F
2K
3!
3Q
3}
3ç
4J
V

2a
2j
2d
2f
3
3j
3e
3g
4l
4O
1a

2d
2L
2n
3i
3d
3m
4h
4f
5q
1j

2g
3a
3c
3L
4
4b
4n
5X
1d

3c
3e
3n
4b
4d
5i
5x
1f

3g
4i
4d
4f
5k
5B
2

4d
4m
5h
5f
6q
2j

5a
5c
6h
6v
2e

5e
6j
6z
2g

7
7u
2l

7m
3O

www.tnb.com

A23

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 24

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
®
®

T&B Bulkhead Fittings
Across Flats

Bulkhead Fitting

Diameter

Thread

Nipple Nut
Included

Cat.
No.

Trade
Size

H050BHD
H075BHD
H100BHD
H125BHD
H150BHD
H200BHD
H250BHD
H300BHD
H350BHD
H400BHD
H500BHD
H600BHD

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
5"
6"

Thru Bulkhead Fitting
Height

Cat.
No.

Trade
Size

H050TBF
H075TBF
H100TBF
H125TBF
H150TBF
H200TBF

d
f"
1"
1b"
1d"
2"

Thru Bulkhead Hub
Cat.
No.

Trade
Size

H050TBH
H075TBH
H100TBH
H125TBH
H150TBH
H200TBH

d"
f"
1"
1b"
1d"
2"

Trade
Size

Thread

Height

Diameter

Across
Flats

A

B

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
5"
6"

d"-14
f"-14
1"-11d
1b"-11d
1d"-11d
2"-11d
2d"-8
3"-8
3d"-8
4"-8
5"-8
6"-8

1u
1v
1L
1A
1m
1B
2s
2l
2l
2l
2z
3

1k
1L
2
2c
2f
3b
3f
4c
5
5d
6e
7L

1
1b
1w
1B
1a
2e
3a
3A
4s
4B
5C
7o

f
A
C
C
C
n
1r
1j
1c
1c
1v
1d

d
w
x
y
y
y
g
C
g
g
g
O

Material –

Hub, Body and Locknut:
Insulating Throat:

zinc or copper free aluminum
Thermoplastic temp. rating – 105°C
Flammability Rating: – 94V-0
Nitrile (BUNA “N”)

Sealing Ring
For Aluminum Bulkheads add suffix A.
For Chrome Plated Bulkheads add suffix CP.
Meets NEMA sealing requirements for NEMA 3R. 4 & 13 enclosures.
CSA Certified for hazardous locations Class II Groups E.F.G. Class III.
U.L. File No. E-3060
CSA File No. 4484

A24

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 25

A
®
®

C

Offset Reducers
Trade
Size

Height

Dia. (Ø)

A
Dia.

B

C

D

E

1d"-f"
1s"-1"
1s"-1b"
2d"-2"

1y
1A
1A
2a

2f
2f
2f
3f

n
1h
1h
1i

z
z
z
n

1C
1C
1C
2C

1s
1l
1g
2y

X
r
o
p

B
Height

Cat. No.
H150-H075ORGR
H150-H100ORGR
H150-H125ORGR
H250-H200ORGR

A

Dia. (Ø)

Material – Offset Reducer and Locknut:
Insulating Throat:

Dia. (0)

Zinc or copper free aluminum
Thermoplastic Temp. Rating – 105°C
Flammability Rating – 94V-0
Nitrile (BUNA “N”)

Sealing Ring
For Aluminum Offset Reducer add suffix A.
For Chrome Plated Offset Reducer add suffix CP.
Meets NEMA sealing requirements for NEMA 3R. 4 & 13 enclosures.
CSA Certified for hazardous locations Class II Groups E.F.G. Class III.
U.L. File No. E-3060
CSA File No. 4484

E

®
®

Capoffs

B

A
C

Capoff

Dia.

Height

Cat.
No.

Trade
Size

Height

Diameter

A

B

C

H050CAP
H075CAP
H100CAP
H125CAP
H150CAP
H200CAP
H250CAP
H300CAP
H350CAP
H400CAP
H500CAP
H600CAP

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
5"
6"

1u
1v
1L
1A
1m
1B
2s
2l
2l
2l
2z
3

1k
1L
2
2c
2f
3b
3f
4c
5
5d
6e
7e

x
x
L
z
z
z
g
g
C
C
C
O

B
1h
1j
1y
1C
2c
2C
3o
4o
4d
5l
6e

i
i
b
b
b
b
b
X
X
X
X
X

Material – Capoff and Locknut:
Insulating Throat:

zinc or copper free aluminum
Thermoplastic temp. rating – 105°C
Flammability Rating – 94V-0
Nitrile (BUNA “N”)

Sealing Ring
For Aluminum Capoff add suffix A.
For Chrome Plated Capoff add suffix CP.
Meets NEMA sealing requirements for NEMA 3R. 4 & 13 enclosures.
CSA Certified for hazardous locations Class II Groups E.F.G. Class III.
U.L. File No. E-3060
CSA File No. 4484

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A25

T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 26

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
Threadless Connector/Coupling
(For Threadless Rigid Metal Conduit and Intermediate Metal Conduit)
8123 Series

8130 Series

8120 Series

Application
• To connect and effectively bond
threadless rigid metal conduit/intermediate metal conduit to a box or
enclosure, or to couple ends of
threadless conduit.
Features
• Steel/Malleable Iron Construction.
• Case hardened ring bites into conduit
for high quality continuity and grip.
• Nylon insulator firmly secured in
place protects conductors and
reduces wire pulling effort by as
much as 50%; prevents thread damage in handling.
• Case hardened steel locknut or malleable iron locknut designed to provide a positive bond.
• Suitable for concrete tight application.
• Capable of carrying ground fault currents up to 10,000 amps RMS (1⁄2"
through 11⁄2" size) and 20,000 amps
RMS (2" and above sizes). …duration
of current 3 cycles.
Listed/Certified by:
U.L. (U.L. File No: E-23018)
CSA (LR-2884, LR-4484)

A26

Standard Material
Nut, Gland. . . . d" to 1" Steel – 1b" to
4" Malleable Iron
Body . . . . . . . . . . . All Malleable Iron
Ring. . . . . . . . Steel (case hardened)
Insulator. . . . . . . . . . . . . . . . . . Nylon
Locknut . . . . . . . . . . . d" thru 2" Steel
(hardened) 2" thru
4" Malleable Iron
Standard Finish
Electro Zinc Plated & Chromate Coated
Range
8123 & 8120 Series . . . . . d" through
4" Size Conduit
8130 Series . . . . . . . . . . . d" through
2" Size Conduit
All hub threads . . . . . . . . . . . Straight
Pipe (NPS)
Conforms to:
U.L. 514B
CSA C22.2 No. 18
NFPA 70-1999 (ANSI)
NEMA FB1
Federal Specification W-F-408
Federal Standard H-28 (Threads)

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 27

A
®
®

Nylon Insulated Threadless Connectors

A split steel ring with diagonal serrations grips
the conduit and bites into it for positive ground.
Makes a permanent connection and eliminates
the need for cutting a thread on the conduit.
Insulation helps to guarantee continuity of service with protection of the conductor at the critical point – the connector bushing. Malleable
iron construction.

Cat. No.
Nylon
Insul.

NonInsul.

Conduit
Size

A

B

C

8123
8223
8323
8423
8523
8623
8723-TB
8823
8853
8973

8121
8221
8321
8421
8521
8621
8721
8821
8851
8971

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

1r
1w
1C
2c
2L
3b
4a
4g
5d
6o

1L
1f
2
2k
2e
2m
3m
4
4a
4g

1d
1d
l
L
f
B
1a
1r
1a
1a

Dimensions (in.)

Available with DURA-PLATE® Finish.
U.L. File No. E-23018
CSA File No. 2884

®
®

Threadless Couplings

Eliminate conduit threading. Tightened with
a wrench they make a U.L. Listed and CSA
Certified concrete-tight connection.
Malleable iron.

Dimensions (in.)

Cat.
No.

Size

A

B

8120
8220
8320
8420
8520
8620
8720
8820
8850
8970

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

1s
1x
1g
2c
2e
3b
3n
4L
5i
5L

2
2j
2L
2m
3e
3m
5c
5d
5d
5d

Available with DURA-PLATE® Finish.
U.L. File No. E-23018
CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A27

T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 28

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
®
®

Threadless Short Elbows – Nylon Insulated
Dimensions (in.)

Cat.
No.

Size

A

B

C

8130
8131

d"
f"

1X
1e

1d
1f

d
l

Available with DURA-PLATE® Finish.
U.L. File No. E-23018
CSA File No. 2884

Ideal for entering enclosure or conduit body
at right angles. Eliminates need to thread
conduit. As with straight couplings, this connector makes a concrete-tight connection.
Malleable iron.
®
®

Threadless Short Elbows

This elbow has all of the advantages of the
insulated short elbow except for the insulation.
Malleable iron.

A28

Dimensions (in.)

Cat.
No.

Size

A

B

C

8030
8031

d"
e"

1c
1L

1d
1f

k
d

Available with DURA-PLATE® Finish.
U.L. File No. E-23018
CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 29

A
T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings
Set Screw Connector/Coupling
(For Threadless Rigid Metal Conduit and Intermediate Metal Conduit)

8125 Series

8124 Series

Application
• To connect and effectively bond
threadless rigid metal conduit or
intermediate metal conduit to a box
or enclosure or to couple ends of
threadless conduit.
Features
• Thickwall steel or malleable iron
body.
• Hardened hex head cup point screw
to provide high quality bond.
• Screw captivated, will not vibrate
loose.
• Nylon insulated throat meets and
exceeds all code requirements for
bushing:
(i) Prevents thinning of insulation.
(ii) Reduces installation effort.
(iii) Prevents first thread damage.
• Coupling provided with positive center stop.
• Suitable for concrete tight application.
• Capable of carrying ground fault currents up to 10,000 amps RMS
(d" through 1d" size) and 20,000
amps RMS (2" and above sizes).

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

Standard Material
Body..............................d" thru 2" Steel
2d" thru 4" Malleable Iron
Locknut ......d" thru 2" Steel (hardened)
2d" thru 4" Malleable Iron
Screw .........................Steel (hardened)
Insulator .......................................Nylon
Standard Finish
Electro Zinc Plated & Chromate Coated
Listed/Certified by:
U.L. (U.L. File No: E-23018)
CSA (LR-2884, LR-4484)
Conforms to:
U.L. 514B
CSA C22.2 No. 18
NFPA 70-1999 (ANSI)
NEMA FB1
Federal Specification W-F-408
Federal Standard H-28 (Threads)

A29

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 30

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
Insulated Set-Screw Connector
Cat.
No.
8125
8225
8325
8425
8525
8625-TB
8725-TB
8825
8855
8975

Eliminate conduit threading with these set
screw connectors. Captive hex head screws
tighten down onto conduit for positive holding
strength and ground. The connectors are furnished with insulated throats reducing wire
pulling effort by as much as 50%. Approved
concrete tight.

Dimensions (in.)

Conduit
Size

A

B

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

1c
1d
1m
2
2j
2k
3c
3k
3g
4i

u
k
{
e
e
L
1
1
1h
1a

Sizes d"-2" made of steel. Sizes 2d"-4" are malleable iron.
Available with DURA-PLATE® Finish.
U.L. File No. E-23018
CSA File No. 2884

®
®

Set Screw Coupling
Cat.
No.
8124
8224
8324-TB
8424
8524
8624
8724
8824-TB
8854
8974

Eliminate the need for threading conduit ends
when joining rigid conduit with these set screw
couplings. Captive hex head screws provide
positive holding strength and ground continuity.
Approved concrete tight.

A30

Conduit
Size

Dimension (in.)

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

2d
2L
2B
3
3c
3e
3g
4b
4n
5c

A

Sizes d"-2" made of steel; sizes 2d"-4" are malleable iron.
Available with DURA-PLATE® Finish.
U.L. File No. E-23018
CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/20/03

3:03 PM

Page 31

A
®
®

Bushed Elbows

The non-insulated elbow has smoothly rounded
shoulders to protect conductor insulation.
Malleable iron.

Dimension (in.)

Cat.
No.

Size

A

B

C

460-TB
461TB
462
463

d"
f"
1"
1b"

1a
1d
1m
2b

1m
2b
2L
3a

e
e
f
f

Available with DURA-PLATE® Finish.
U.L. File No. E 23018
CSA File No. 2884
®
®

Short Elbows – Nylon Insulated

The integral insulation of the insulated elbow is
a guarantee that the bushing of every fitting
will be smooth. Malleable iron.

Dimension (in.)

Cat.
No.

Size

4290
4291
4292
4293
4294
4295

d"
f"
1"
1b"
1d"
2"

A

B

C

1r
1k
1z
2r
2v
3

1b
1j
1l
2h
2i
2l

d
l
L
m
m
m

Available with DURA-PLATE® Finish.
Not U.L. or CSA.
®
®

Short Elbows

When an insulated elbow is not desired, the
non-insulated short elbow should be used.
Malleable iron.

Dimension (in.)

Cat.
No.

Size

4250
4251
4252
4253
4254
4255

d"
f"
1"
1b"
1d"
2"

A

B

C

1j
1w
1m
2s
2l
3p

1b
1j
1l
2h
2i
2l

k
d
e
L
L
L

Available with DURA-PLATE® Finish.
U.L. File #E-23018
CSA File No. 589

Conduit Nipples – Die Cast Zinc 1" Long
A

B

Cat. No.

Size

A

B

HA-211
HA-212
HA-213

d"
f"
1"

1"
1"
1"

n"
1i"
1k"

U.L. File No. E-1275 d" & f" only

Offset Nipples – Die Cast Zinc
A

3/4"
B

Cat. No.

Size

A

B

HO-221
HO-222
HO-223
HO-224
HO-225
HO-226

d"
f"
1"
1b"
1d"
2"

2.60"
2.62"
2.68"
2.85"
2.88"
3.19"

1.00"
1.32"
1.51"
1.85"
2.08"
2.71"

f" offset.
U.L. File No. E-1275

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A31

T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 32

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
Threaded Coupling (Erickson ® Coupling)
(For Threaded Rigid Metal Conduit and Intermediate Metal Conduit)

674 Series
675AL Series

Application
• To couple and effectively bond
threaded ends of rigid metal
conduit/intermediate metal conduit
where neither length of conduit can
be rotated.

675AL Series
Bushing & Case ....................Aluminum
Ring ......................................Aluminum

Features
• Malleable Iron/Steel/Copper free
Aluminum Construction.
• Free fitting threads insure easy
assembly.
• Permits conduit coupling without
rotating either conduit.
• Provides rigid in-line coupling with
high quality grounding; will not loosen
under vibration.
• Suitable for concrete tight application.
• Capable of carrying ground fault currents up to 10,000 amps RMS (d"
through 1d" size) and up to 20,000
amps RMS (2" and above) (duration
of fault current 3 cycles) (674 series
tested).
Standard Material
674 Series
Bushing & Case .............Malleable Iron
Ring ...................Steel & Malleable Iron

Standard Finish
674 Series: Electro Zinc Plated &
Chromate Coated
675AL Series: Degreased
Range
c" thru 6" Conduit (malleable iron)
d" thru 6" Conduit (aluminum)
All straight pipe threads (NPS)
Listed/Certified by:
U.L. (U.L. File No. E-23018)
CSA (LR-2884, LR-4484)
Conforms to:
U.L. 514B
CSA C22.2 No. 18
NEMA FB1
NFPA 70-1999 (ANSI)
Federal Specification W-F-408
Federal Standard H-28 (Threads)

®
®

ERICKSON® Couplings

With an ERICKSON® coupling, a conduit run
may be completed when neither conduit can be
turned. A conduit run may also be broken without taking down the whole run. Conduit joined
with ERICKSON® Couplings is rigid and in line
and vibration will not loosen the connections.
Malleable iron.

Cat.
No.

Cat.
No.
Alum.*

Size

674
675
676
677
678
679
680TB
681
682
683
684
685
686
687

–
675AL
676AL
677AL
678AL
679AL
680AL
681AL
682AL
683AL
684AL
685AL
686AL
687AL

c"
d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
4d"
5"
6"

Dimensions (in.)
A
1a
1v
1l
1C
2c
2e
3r
3O
4k
5
5d
6b
6A
8

B
1a
1b
1u
1e
1m
1O
2r
2L
2C
3
3i
3v
3f
4o

* Copper Free Aluminum.
U.L. Listed and CSA Certified concrete-tight.
U.L. File No. E-23018
CSA File No. 2884

A32

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 33

A
®
®

Panel Connector Extensions

Ideal when longer thread length is needed.
Will combine with any fitting having a male
thread. Male thread of panel connector extension is 1" long. Malleable iron.

Cat.
No.
1440
1441
1442
1443

Dimensions (in.)
Size

A

B

C

d"
f"
1"
1b"

1b
1c
1b
1b

1p
1X
1x
1n

1g
2
1n
1j

U.L. File No. E-23018
CSA File No. 2884
®
®

Male Enlargers*
Cat.
No.
1245
1246
1244
1247

Adapt an outlet hole to the next larger size of
conduit. Rough ends of conduit carefully covered by built-in bushing. Malleable iron.

Dimensions (in.)
Size
d" to f"
f" to 1"
1" to 1b"
1b" to 1d"

A

B

C

1u
1L
2h
2j

1h
1b
1X
1c

d
v
d
l

* All items shown in this chart are suitable for use in hazardous locations where general purpose equipment is specifically permitted by
the NEC; Class I, Div. 2; Class II, Div. 1 & 2; Class III, Div. 1 & 2, NEC 501-4(b); 502-4(a)(b); 503-3(a)(b).
Available with DURA-PLATE® Finish.
U.L. File No. E-23018
CSA File No. 2884
®
®

Female Reducers*
Cat.
No.

Adapt any outlet to the next smaller size of conduit. Hex shoulder makes wrench tightening
convenient. Malleable iron.

1250
1261
1251
1262
1263
1252
1253
1254
1255
1256
1257
1258

Dimensions (in.)
Size
f" to d"
1" to d"
1" to f"
1b" to d"
1b" to f"
1b" to 1"
1d" to 1b"
2" to 1d"
2d" to 2"
3" to 2d"
3d" to 3"
4" to 3d"

A

B

C

1a
1k
1c
1m
1m
1f
2
2c
3
3e
4a
4e

e
y
L
z
z
A
m
1i
1b
1d
1l
1l

i
i
i
i
i
r
b
s
c
d
d
d

* All items shown in this chart are suitable for use in hazardous locations where general purpose equipment is specifically permitted by
the NEC; Class I, Div. 2; Class II, Div. 1 & 2; Class III, Div. 1 & 2, NEC 501-4(b); 502-4(a)(b); 503-3(a)(b).
Available with DURA-PLATE® Finish.
U.L. File No. E-23018
CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A33

T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings

412031.A01 FIT 3/12

3/13/03

4:45 PM

Page 34

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
®
®

Threaded Reducers*
Cat. No.
Stl. on MI

For reducing the threaded opening in conduit
bodies or any female threaded fitting. Smooth,
built-in bushing completely covers rough ends
of conduit. Iron or steel construction. Steel thru
606, also 614 & 615.

600TB
601TB
602TB
603TB
604TB
605
606
607
608
609
610
611
612
613
614
615

Dimension (in.)
Alum.

Size

A

600ALTB
601ALTB
602ALTB
603ALTB
604ALTB
605AL
606AL
607AL
608AL
609AL
610AL
611AL
612AL
613AL
614AL
615AL

d" to c"
f" to d"
1" to d"
1" to f"
1b" to d"
1b" to f"
1b" to 1"
1d" to d"
1d" to f"
1d" to 1"
1d" to 1b"
2" to d"
2" to f"
2" to 1"
2" to 1b"
2" to 1d"

l
l
e
e
m
g
n
m
m
n
f
n
n
n
n
g

U.L. File No. E-23018
CSA File No. 2884
®
®

Reducing Washers

Washers reduce knockout hole in outlet box.
Newly designed of galvanized steel. These
washers, used in pairs, interlock and form a
rib which centers the washers and conduit in
the knockout.

Dimensions (in.)

Cat.
No.

Size

A

B

3700
3701

f" to c"
f" to d"

1c
1c

}
g

3702
3703
3704

1" to c"
1" to d"
1" to f"

1e
1e
1e

}
g
1p

3705
3706
3707
3708

1b" to c"
1b" to d"
1b" to f"
1b" to 1"

2
2
2
2

}
g
1p
1R

3709
3710
3711
3712
3713

1d" to c"
1d" to d"
1d" to f"
1d" to 1"
1d" to 1b"

2b
2b
2b
2b
2b

}
g
1p
1R
1z

3714
3715
3716
3717
3718

2" to d"
2" to f"
2" to 1"
2" to 1b"
2" to 1d"

2f
2f
2f
2f
2f

g
1p
1R
1z
1O

U.L. File No. E-13938
CSA File No. 2884

A34

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 35

A
T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings
Conduit Straps
(For Rigid Metal Conduit and Intermediate Metal Conduit)

1275 Series
1276AL Series

Conduit Strap
Conduit
Conduit
Spacer
Supporting
Wall

Application
• To support and securely fasten rigid
metal conduit and intermediate metal
to the supporting surface.

Standard Finish

Features
• Rugged malleable iron/copper free
aluminum construction – snugly fits
on the conduit.
• Designed to prevent accumulation of
moisture and start of corrosion on
vertical run of conduit (A).
• Galvanized finish…1275 Series.
• Copper free aluminum…1276AL
Series.

Range

1275 Series . . . . . . . . . 1276AL Series
Hot Dipped . . . . . . . . . . . . . . . As Cast
Galvanized
1275 Series . . . . . . . . 1276AL Series
c" through . . . . . d" through 6" conduit
6" conduit
Listed/Certified by:
CSA (LR-2884, LR-4484)
Conforms to:
CSA C22.2 No. 18
NFPA 70-1999 (ANSI)

Standard Material
1275 Series . . . . . . . . . 1976AL Series
Malleable Iron . . . . . . . . All copper free
aluminum

®

B

Pipe Straps – Malleable Iron or Aluminum

A

Cat. No.
C

Designed to fit each size of conduit snugly.
High reinforcing ribs on each side increase
strength, reduce weight. Hot-dipped galvanized
finish. Malleable iron.

Mal. Iron
1275†
1276†
1277†
1278†
1279†
1280†
1281
1282*
1283*
1284
1285*
1286
1287
1288

Alum.

Size

1275AL
1276AL†
1277AL†
1278AL†
1279AL†
1280AL
1281AL
1282AL
1283AL
1284AL
1285AL
1286AL
1287AL
1288AL

c"
d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
4d"
5"
6"

A
1g"
2q"
2l"
3"
3f"
4i"
5i"
5n"
6L"
7x"
8j"
9i"
9n"
11d"

B
L"
y"
L"
f"
m"
n"
1a"
1d"
1e"
1f"
1g"
1n"
2"
2k"

C
f"
1o"
1r"
1w"
1g"
2a"
2å"
2f"
3X"
3C"
4u"
4n"
5v"
6w"

Screw
Size
#12
b"
b"
b"
j"
c"
k"
d"
d"
e"
e"
e"
e"
e"

* May be used with EMT of same size.
† Not snap on type.
U.L. not applicable.
CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A35

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 36

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
®

Pipe Straps – Steel

C

A
B

Elongated bolt hole makes alignment easy,
even when holes in mounting surface are off
center. Snap on features. Steel.

B
A
C

Malleable iron. Designed to fit each size of
conduit snugly. High reinforcing ribs on each
side increase strength, reduce weight.

Cat.
No.

Conduit
Size

A

1210†
1211
1212
1213

c"
d"
f"
1"

1v
2
2j
3m

1214
1215
1216

1b"
1d"
2"

2O
3z
4k

C

Screw
Size

f
f
3f
f

L
n
1"
1å

b"
b"
b"
b"

1l
1m
2j

1l
1m
2j

c"
c"
c"

B

† Not snap on type.
U.L. not applicable.
CSA File No. 2884

Corrosion Resistant PVC Coated Rigid Conduit Straps
Dimensions (in.)

Cat.
No.

Size

Bolt
Size

A

B

C

1275CR
1276CR
1277CR
1278CR
1279CR
1280CR
1281CR

c"
d"
f"
1"
1b"
1d"
2"

b"
b"
b"
b"
c"
c"
d"

1g
2q
2l
3
3f
4i
5i

L
y
L
f
m
n
1a

f
1o
1r
1w
1g
2a
2å

U.L. not applicable.

A36

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 37

A
T&B ® Fittings

Rigid and Intermediate Metal Conduit Fittings
Conduit Spacers
(For Rigid Metal Conduit, Intermediate Metal Conduit and Electrical
Metallic Tubing)
1350 Series
1350AL Series

Application
• Provides mounting surface for conduit where installation requires air
space between conduit and supporting surface.
Features
• Prevents conduit rusting from wall
condensation.
• Spacers can be stacked one atop
the other facilitating installation and
eliminating expensive conduit off setting (A).
• Designed to cover wide range;
marked with accurate size marking
for proper positioning (B).
• Galvanized finish on 1350 Series.
• Copper free aluminum alloy,
1350AL Series.

Standard Material
1350 Series . . . . . . . . 1350AL Series
Malleable Iron . Copper free aluminum
Standard Finish
1350 Series . . . . . . . . 1350AL Series
Hot Dipped . . . . . . . . . . . . . . As Cast
Galvanized
Range
d" through 6" conduit
Listed/Certified by:
CSA (LR-2884, LR-4484, LR-4484)
Conforms to:
CSA C22.2 No. 18
NFPA 70-1999 (ANSI)

®

Pipe Spacers
Cat. No.
Mal. Iron

Used with T&B conduit straps to permit space
between conduit and mounting surface.
Eliminates need for costly offset-bending conduit and possible corrosive moisture traps
when conduit is mounted directly to a surface.
Hot-dipped galvanized finish, premountable
and stackable to eliminate offsetting.
Malleable iron.

1350
1351
1352
1353
1354

Dimensions (in.)

Alum.

Size

Screw
Size

A

1350AL
1351AL
1352AL
1353AL
1354AL

d", f", 1"
1b"-1d"-2"
2d"-3"
3d"-4"
4d"-5"-6"

#7
#12
#12
#14
#16

3"
5"
9l"
7l"
10l"

B
g"
1i"
1f"
2"
2l"

Conforms to NEC SECT. 300-5-c
U.L. not applicable.
CSA File Nos. 2884 and 4484

Pipe Spacers – PVC coated
Cat.
No.

Corrosion-resistant, PVC-coated, malleable
iron. Pre-mountable, stackable to eliminate offsetting.
Spacers can be stacked for offsets on wall
or into outlet box. Prevents conduit rusting
from wall condensation. Eliminates offsetting of conduit.

1350CR
1351CR
1352CR
1353CR
1354CR

Conduit
Size
d"-f"-1"
1b"-1d"-2"
2d"-3"
3d"-4"
4d"-5"-6"

Dimensions (in.)

Screw
Size

A

#7
#12
#12
#14
#16

3
5
6l
7l
10l

B
g
c
1f
2
2l

U.L. not applicable.
Conforms to NEC SECT. 300-5-c.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A37

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 38

T&B ® Fittings

A
Rigid and Intermediate Metal Conduit Fittings
®
®

TITE-BITE® Combination Couplings –
Armored Cable for Threaded Rigid
Dimensions (in.)

Cat.
No.

Size

A

B

440
441
442

d"
f"
1"

1e
1f
2

1B
2a
2w

U.L. File No. E-23018
CSA File No. 2884

A one-piece fitting that couples armored cable
or flexible conduit to threaded rigid conduit.
Tite-Bite® wedge holds conduit securely with a
double grip. With a Chase ® nipple this fitting
will connect flexible conduit to outlet boxes,
allowing more wiring space in the box than the
usual connector. U.L. Listed as a grounding
means under NEC 350-5. Malleable iron.
®
®

Entrance Ells

T&B entrance ells mount flat against the wall
eliminating the need for offsetting the conduit.
Designed for a straight pull in either direction
and carefully bushed, these entrance ells make
it easy to pull heavy wires without damage to
the insulation. Made of copper free aluminum.

Dimensions (in.)

Cat.
No.

Conduit
Size

A

C

1490
1491
1492
1493
1494
1495
1496
1497
1498
1499

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

3™
3l
4b
5M
6b
6f
13!
13!
16S
16S

1x
1g
2r
2m
2g
3&
5g
6d
7w
7w

U.L. File No. E-23018
CSA File Nos. 2884 and 589

Beam Clamps Adjustable
Includes bolts. Steel

Cat.
No.

Description
Fits Flange 2f"-7c"
Fits Flange 7"-12"
Special Bolt and 3 Nuts

700TB
701
703
CSA File No. 2884.

®

Conduit Supports
Cat.
No.

These supports will fit any flange, tapered or
straight up to 5⁄8" thick. The broad hook holds
the conduit at any desired angle. Holds standard rigid conduit, E.M.T., or I.M.C.
Malleable iron.

A38

Size

690
691TB
692TB
693TB

d"
f"
1"
1b"

CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 39

A
T&B ® Fittings

Conduit Outlet Bodies
T&B Conduit Fittings for Ordinary and
Hazardous Locations
Thomas & Betts offers a broad range of conduit bodies, conduit boxes, conduit
fittings, unions, sealing fittings, drains and cable fittings for both ordinary and
hazardous locations. Complete information on applications, features, materials,
finishes, size range and certifications is provided in the following pages.

Conduit Bodies (for ordinary locations)
For raceway systems to provide pull outlets, 90° bends, splices, taps, mounting
outlets, etc.
FORM 7
For neat, compact installation of rigid threaded conduit.
FORM 8
For heavier conductors using rigid threaded conduit.
Red•Dot® Aluminum For rigid threaded conduit installation – copper-free
Die-Cast
aluminum.
Red•Dot® Thinwall
For set-screw installation using thinwall conduit.
(EMT)
(EMT) – copper-free aluminum.
Mogul
For larger conduits, spacious, accessible wiring chambers.
Conduit Fittings

Cast Device Boxes (for ordinary locations)
For raceway systems to accommodate wiring devices, serve as pull boxes, and
provide entrances for taps and splices.
FS/FD Single and Double Gang Cast Device Boxes

Cast Conduit Outlet Boxes (for hazardous locations)
Round cast outlet boxes used with rigid conduit to serve as pull and splice
boxes, easy access to wiring, act as a housing for instruments, apparatus, etc.
GUA Conduit Outlet Bodies

Reducers, Plugs, Unions (for ordinary and hazardous locations)
Includes reducers for connecting conduit of dissimilar dimensions, plugs for
unused conduit openings and hubs, and unions for threaded conduit systems.
RE, PLG REC Reducers, Plugs and Adapters, UNY/UNF Unions

Sealing Fittings and Drains (for ordinary and hazardous locations)
Cast fittings used with rigid conduit to seal sections from passage of vapors,
flame or gases or explosions. Drains provide ventilation as a breather and as a
drain in moist locations.
EYS/EYD Sealing Fittings & ECD Drains

Cable Fittings (for ordinary and hazardous locations)
For armored, metal clad, jacketed or unjacketed and unarmored cables through
a bulkhead or enclosure in ordinary or hazardous areas.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A39

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 40

T&B ® Fittings

A
Form 7, Form 8, and Red•Dot® Conduit Outlet Bodies
Conduit Outlet Bodies
Application
Conduit Bodies are installed in conduit systems to:
• Connect conduit sections.
• Act as pull outlets when conductors are being installed.
• Provide easy access for splices in branch conductors.
• Make 90-degree bends in conduit runs.
• Act as mounting outlets for wiring devices and lighting fixtures.
• Provide access to conductors for maintenance and future system changes.
Features
• Standard features include tapered (NPT) threads, integral bushings to protect
wire insulation.
• T&B Form 7 bodies and covers are interchangeable with other manufacturer’s
Form 7 bodies and covers.
• T&B Form 8 bodies and covers are interchangeable with other manufacturer’s
Form 8 bodies and covers.
Materials
• Conduit Bodies (Form 7 and Form 8) - Sand cast class 30 Gray iron alloy.
• Red•Dot® die cast aluminum, copper-free.
• Covers – Sand cast gray iron alloy, and stamped sheet steel-stainless steel
screws.
• Gaskets – Neoprene
Finish
• Conduit Bodies – zinc-plating with an aluminum acrylic coating.
• Covers – gray iron zinc-plating with an aluminum acrylic coating, and
stamped steel zinc-plating with a clear chromate coating.
Compliances
• UL Standard: 514A, 514B
• Fed. Spec: W-C-586D
• CSA Standard: C22.2 No. 18

A40

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 41

A
®

®
®

Threaded Rigid Bodies
Shape

Hub Size
1/2

3/4

1

1-1/4

1-1/2

2

2-1/2

3

3-1/2

4

LB

Form 7
Form 8
Threaded Aluminum
EMT Aluminum

LB17
LB18
ALB1
BLB1

LB27
LB28
ALB2
BLB2

LB37
LB38
ALB3
BLB3

LB47
LB448
ALB4
BLB4

LB57
LB58
ALB5
BLB5

LB67
LB68
ALB6
BLB6

LB77
LB78
ALB7
BLB7

LB87
LB888
ALB8
BLB8

LB97
LB98
ALB9
BLB9

LB107
LB108
ALB10
BLB10

T17
T18
AT1
BT1

T27
T28
AT2
BT2

T37
T38-TB
AT3
BT3

T47
T448
AT4
BT4

T57
T58
AT5
BT5

T67
T68
AT6
BT6

T77
T78
AT7

T87
T88-TB
AT8

T97

T107

T

Form 7
Form 8
Threaded Aluminum
EMT Aluminum

AT9

AT10

C

Form 7
Form 8
Threaded Aluminum
EMT Aluminum

C17
C18
AC1
BC1

C27
C28
AC2
BC2

C37
C38
AC3
BC3

C47
C448
AC4
BC4

C57
C58-TB
AC5
BC5

C67
C68
AC6
BC6

C77-TB
C78
AC7

C87
C88
AC8

AC9

AC10

LL17
LL18
ALL1
BLL1

LL27
LL28
ALL2
BLL2

LL37
LL38
ALL3
BLL3

LL47
LL448
ALL4
BLL4

LL57
LL58
ALL5
BLL5

LL67
LL68
ALL6
BLL6

LL77
LL78
ALL7

LL87
LL888
ALL8

LL97

LL107

LL

Form 7
Form 8
Threaded Aluminum
EMT Aluminum

ALL9

ALL10

LR17
LR18
ALR1
BLR1

LR27
LR28
ALR2
BLR2

LR37
LR38
ALR3
BLR3

LR47
LR448
ALR4
BLR4

LR57
LR58
ALR5
BLR5

LR67
LR68
ALR6
BLR6

LR77
LR78
ALR7

LR87
LR888
ALR8

LR97

LR107

LR

Form 7
Form 8
Threaded Aluminum
EMT Aluminum

ALR9

ALR10

X17
X18

X27
X28

X37
X38

X47
X448

X57
X58

X67
X68

L27-TB
ALRL2
BLRL2

L37-TB
ALRL3
BLRL3

L47-TB
ALRL4
BLRL4

L57-TB
ALRL5
BLRL5

L67-TB
ALRL6
BLRL6

X

Form 7
Form 8

*L

Form 7
L17-TB
Threaded Aluminum ALRL1
EMT Aluminum
BLRL1

E

Form 7
Threaded Aluminum

E17
AE1

E27
AE2

E27
AE3

TA

Form 7

TA17

TA27

TA37

TA47

TA57

TA67

TB

Form 7

TB17-TB
TB18

TB27
TB28

TB37
TB38

TB47
TB48

TB57
TB58

TB67
TB68

*Furnished with one stamped steel cover

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A41

T&B ® Fittings

Form 7, Form 8, and Red•Dot Conduit Outlet Bodies

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 42

T&B ® Fittings

A
Form 7, Form 8, and Red•Dot® Conduit Outlet Bodies
Covers and Gaskets
Shape

Stamped Steel

Gray Iron

Gasket

Hub Size
1/2

3/4

1

1-1/4

1-1/2

2

2-1/2

3

3-1/2

4

Form 7
Form 8
Red•Dot®

170S
180
SCV1

270S
280
SCV2

370S
380
SCV3

470S
480
SCV4

570S
580
SCV4

670S
680
SCV5

870S
880
CV6

870S
880
CV6

970S
980
CV7

970S
980
CV7

Form 7
Form 8

170F
180F

270F
280F

370F
380F

470F
480F

570F
580F

670F
680F

870F
880F

870F
880F

970F
980F

970F
980F

Form 7

GASK
571

GASK
572

GASK
573

GASK
574

GASK
575

GASK
576

GASK
578

GASK
578

GASK
579

GASK
579

Form 8

GASK
581N

GASK
582N

GASK
583N

GASK
584N

GASK
585N

GASK
586N

GASK
588N

GASK
588N

GASK
589N

GASK
589N

Red•Dot®

GKN1

GKN2

GKN3

GKN4

GKN4

GKN5

GKN6

GKN6

GKN7

GKN7

For ordering purposes please use GASK in the catalog number. (Example: GASK 571)

A42

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 43

A
®

®
®

LB Form 7

C

D
E

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

LB17
LB27
LB37
LB47
LB57
LB67
LB77
LB87
LB97
LB107

d
f
1
1b
1d
2
2d
3
3d
4

4.60
5.25
6.00
6.45
7.25
8.30
10.55
10.55
12.85
12.85

2.20
2.40
2.65
3.20
3.90
4.45
5.20
5.95
6.70
7.20

1.35
1.65
1.80
2.20
2.45
3.10
4.25
4.25
5.25
5.25

.95
1.15
1.35
1.80
2.05
2.45
3.60
3.60
4.55
4.55

3.20
3.80
4.55
5.00
5.45
6.40
8.40
8.40
10.25
10.25

CI
4.0
6.6
10.6
18.8
26.4
51.0
102.0
132.0
210.0
243.0

®
®

B

A
LB Form 7 and Form 8

LB Form 8
Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

CI

LB18
LB28
LB38
LB48
LB58
LB68
LB78
LB888
LB98
LB108

d
f
1
1b
1d
2
2d
3
3d
4

4n
5l
6d
7w
9a
11
13n
13n
16g
16g

2.219
2.438
2.813
3X
4o
4u
6a
6d
7l
7m

1c
1l
1f
2i
2f
3f
5
5
6b
6b

1
1i
1c
1f
2a
3
4b
4b
5k
5k

3j
3j
4l
5j
6d
8l
10g
10g
13k
13k

4.9
8.0
13.0
23.5
45.0
88.0
110.0
110.0
250.0
250.0

LB Threaded Aluminum
Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

F

CI

ALB1
ALB2
ALB3
ALB4
ALB5
ALB6
ALB7
ALB8
ALB9
ALB10

d
f
1
1b
1d
2
2d
3
3d
4

3g
4e
5c
7b
7b
9d
12b
12b
15
15

4s
5a
5n
7g
7g
9m
13
13
16j
16j

1j
1w
1f
2d
2d
3a
4d
4d
5d
5d

1k
1e
17g
2d
2f
3k
3g
4d
5l
5l

3d
4b
4n
6d
6j
8
10B
10d
13d
13d

2h
2k
2f
3l
3m
4d
5b
5g
6n
6n

4.3
7.3
11.8
32.0
32.0
69.5
190.0
190.0
366.0
366.0

LB EMT Aluminum

LB Threaded Aluminum
and EMT Aluminum

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

F

CI

BLB1
BLB2
BLB3
BLB4
BLB5
BLB6
BLB7
BLB8
BLB9
BLB10

d
f
1
1b
1d
2
2d
3
3d
4

3g
4e
5c
7b
7b
9d
12b
12b
15
15

4s
5a
5n
7g
7g
9m
13
13
16j
16j

1j
1w
1f
2d
2d
3a
4d
4d
5d
5d

1k
1e
17g
2d
2f
3k
3g
4d
5l
5l

3d
4b
4n
6d
6j
8
10B
10d
13d
13d

2h
2k
2f
3l
3m
4d
5b
5g
6n
6n

4.3
7.3
11.8
32.0
32.0
69.5
190.0
190.0
366.0
366.0

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A43

T&B ® Fittings

Form 7, Form 8, and Red•Dot Conduit Outlet Bodies

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 44

T&B ® Fittings

A
Form 7, Form 8, and Red•Dot® Conduit Outlet Bodies
®
®

T Form 7

C

D
E

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

CI

T17
T27
T37
T47
T57
T67
T77
T87
T97
T107

d
f
1
1b
1d
2
2d
3
3d
4

5.60
6.20
7.35
7.30
8.60
9.50
12.10
12.10
14.65
14.65

1.80
2.00
2.30
2.30
2.60
3.20
3.65
4.40
4.90
5.40

2.35
2.60
3.10
3.05
3.80
4.25
5.80
5.80
7.05
7.05

.95
1.15
1.35
1.80
2.05
2.45
3.60
3.60
4.55
4.55

3.20
3.80
4.55
5.00
5.45
6.40
8.40
8.40
10.25
10.25

6.0
9.1
16.9
19.3
27.5
50.0
102.0
132.0
210.0
243.0

®

B

®

T Form 8
A
T Form 7 and Form 8

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

T18
T28
T38-TB
T48
T58
T68
T78
T88-TB

d
f
1
1b
1d
2
2d
3

5W
6s
7j
8d
10c
12b
15e
15e

1f
2
2b
2e
2A
3l
4k
4m

2q
2j
2e
3q
4
5
6W
6W

1
1i
1c
1f
2a
3
4b
4b

3j
3n
4l
5j
6d
8l
10g
10g

CI
6.0
9.0
15.0
24.0
46.5
88.0
110.0
110.0

T Threaded Aluminum
Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

F

G

CI

AT1
AT2
AT3
AT4
AT5
AT6
AT7
AT8
AT9
AT10

d
f
1
1b
1d
2
2d
3
3d
4

3g
4e
5c
7b
7b
9d
12b
12b
15
15

4c
5a
5n
7g
7g
10i
13
13
16j
16j

1Q
1w
1f
2d
2d
3a
4d
4d
5d
5d

1c
1e
1g
2d
2f
3l
4d
4d
5l
5l

2u
2A
3b
4i
4i
5u
6g
6g
8m
8m

2h
2X
2e
3w
3w
4
5A
5A
6m
6m

m
n
1
1c
1d
1O
2k
2k
3
3

4.3
7.3
11.8
32.0
32.0
69.5
190.0
190.0
366.0
366.0

T EMT Aluminum

T Threaded Aluminum
and EMT Aluminum

A44

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

F

G

CI

BT1
BT2
BT3
BT4
BT5
BT6

d
f
1
1b
1d
2

3g
4e
5c
7b
7b
9d

4c
5a
5n
7g
7g
10i

1Q
1w
1f
2d
2d
3a

1c
1e
1g
2d
2f
3l

2u
2A
3b
4i
4i
5u

2h
2X
2e
3w
3w
4

m
n
1
1c
1d
1O

4.3
7.3
11.8
32.0
32.0
69.5

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 45

A
®

®
®

C Form 7

D

C
E

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

CI

C17
C27
C37
C47
C57
C67
C77-TB
C87

d
f
1
1b
1d
2
2d
3

5.45
6.05
6.75
7.30
8.60
9.50
12.10
12.10

1.40
1.60
1.90
2.30
2.60
3.20
3.65
4.40

1.45
1.65
1.80
2.20
2.45
3.05
4.25
4.25

.95
1.15
1.35
1.80
2.05
2.45
3.60
3.60

3.20
3.80
4.55
5.00
5.45
6.40
8.40
8.40

4.0
6.6
10.6
18.8
26.4
51.0
102.0
132.0

®

B

®

C Form 8
A
C Form 7 and Form 8

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

C18
C28
C38
C48
C58-TB
C68
C78
C88

d
f
1
1b
1d
2
2d
3

5W
6s
7j
8d
10c
12b
15e
15e

1k
1W
1n
2c
2A
3l
4k
4m

1c
1i
1f
2i
2f
3f
5
5

1
1i
1c
1f
2a
3
4b
4b

3j
3n
4l
5j
6d
8l
10g
10g

CI
4.9
8.0
13.0
23.5
45.0
88.0
110.0
110.0

C Threaded Aluminum
Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

F

G

CI

AC1
AC2
AC3
AC4
AC5
AC6
AC7
AC8
AC9
AC10

d
f
1
1b
1d
2
2d
3
3d
4

3g
4e
5c
7b
7b
9d
12b
12b
15
15

4c
5a
5n
7g
7g
10i
13
13
16j
16j

1Q
1w
1f
2d
2d
3a
4d
4d
5d
5d

1c
1e
1g
2d
2f
3l
4d
4d
5l
5l

2u
2A
3b
4i
4i
5u
6g
6g
8m
8m

2h
2X
2e
3w
3w
4
5A
5A
6m
6m

m
n
1
1c
1d
1O
2k
2k
3
3

4.3
7.3
11.8
32.0
32.0
69.5
190.0
190.0
366.0
366.0

C EMT Aluminum

T Threaded Aluminum
and EMT Aluminum

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

F

G

CI

BC1
BC2
BC3
BC4
BC5
BC6

d
f
1
1b
1d
2

3g
4e
5c
7b
7b
9d

4c
5a
5n
7g
7g
10i

1Q
1w
1f
2d
2d
3a

1c
1e
1g
2d
2f
3l

2u
2A
3b
4i
4i
5u

2h
2X
2e
3w
3w
4

m
n
1
1c
1d
1O

4.3
7.3
11.8
32.0
32.0
69.5

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A45

T&B ® Fittings

Form 7, Form 8, and Red•Dot Conduit Outlet Bodies

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 46

T&B ® Fittings

A
Form 7, Form 8, and Red•Dot® Conduit Outlet Bodies
®
®

LL Form 7

C

D
E

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

CI

LL17
LL27
LL37
LL47
LL57
LL67
LL77
LL87
LL97
LL107

d
f
1
1b
1d
2
2d
3
3d
4

4.60
5.25
6.00
6.45
7.90
8.30
10.55
10.55
12.85
12.85

1.40
1.60
1.90
2.30
2.60
3.20
3.65
4.40
4.90
5.40

1.45
1.65
2.60
3.05
3.80
4.25
5.80
5.80
7.03
7.03

.95
1.15
1.35
1.80
2.05
2.45
3.60
3.60
4.55
4.55

3.20
3.80
4.55
5.00
5.45
6.40
8.40
8.40
10.25
10.25

4.0
6.6
10.6
18.6
26.4
51.0
102.0
132.0
210.0
243.0

®
®

B
A
LL Form 7 and Form 8

LL Form 8
Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

CI

LL18
LL28
LL38
LL48
LL58
LL68
LL78
LL888

d
f
1
1b
1d
2
2d
3

4n
5l
6v
7w
9a
11
13n
13n

1k
1W
1n
2c
2A
3l
4k
4m

2q
2j
2e
3q
4
5
6W
6W

1
1i
1c
1f
2a
3
4b
4b

3j
3n
4l
5j
6d
8l
10g
10g

4.9
8.0
13.0
23.5
45.0
88.0
110.0
110.0

LL Threaded Aluminum
Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

F

G

H

CI

CI

ALL1
ALL2
ALL3
ALL4
ALL5
ALL6
ALL7
ALL8
ALL9
ALL10

d
f
1
1b
1d
2
2d
3
3d
4

3g
4e
5c
7b
7b
9d
12b
12b
15
15

3d
4a
4g
6d
6d
8l
11b
11b
14k
14k

4j
5a
5j
7g
7g
10i
13
13
16b
16b

1j
1w
1f
2d
2d
3a
4d
4d
5d
5d

1c
1e
1g
2f
2f
3k
4d
4d
5d
5d

3l
4a
4g
6j
6j
8i
10b
10b
12f
12f

2
2j
2d
3c
3c
3n
5d
5d
6d
6d

A
g
1
1d
1d
1n
2g
2g
3
3

4.3
7.3
11.8
32.0
32.0
69.5
190.0
190.0
366.0
366.0

4.8
7.5
12.5
36.5
36.5
73.8

LRL Style
Only

LL EMT Aluminum

LL Threaded Aluminum
and EMT Aluminum

A46

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

F

G

H

CI

BLL1
BLL2
BLL3
BLL4
BLL5
BLL6

d
f
1
1b
1d
2

3g
4e
5c
7b
7b
9d

3d
4a
4g
6d
6d
8l

4j
5a
5j
7g
7g
10i

1j
1w
1f
2d
2d
3a

1c
1e
1g
2f
2f
3k

3l
4a
4g
6j
6j
8i

2
2j
2d
3c
3c
3n

A
g
1
1d
1d
1n

4.3
7.3
11.8
32.0
32.0
69.5

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

Style
CI LRLOnly

4.8
7.5
12.5
36.5
36.5
73.8

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 47

A
®

®
®

LR Form 7

E
D

C

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

CI

LR17
LR27
LR37
LR47
LR57
LR67
LR77
LR87
LR97
LR107

d
f
1
1b
1d
2
2d
3
3d
4

4.60
5.25
6.00
6.45
7.90
8.30
10.55
10.55
12.85
12.85

1.40
1.60
1.90
2.30
2.60
3.20
3.65
4.40
4.90
5.40

1.45
1.65
2.60
3.05
3.80
4.25
5.80
5.80
7.03
7.03

.95
1.15
1.35
1.80
2.05
2.45
3.60
3.60
4.55
4.55

3.20
3.80
4.55
5.00
5.45
6.40
8.40
8.40
10.25
10.25

4.0
6.6
10.6
18.8
26.4
51.0
102.0
132.0
210.0
243.0

®
®

B

LR Form 8
A
LR Form 7 and Form 8

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

CI

LR18
LR28
LR38
LR48
LR58
LR68
LR78
LR888

d
f
1
1b
1d
2
2d
3

4n
5l
6v
7w
9a
11
13n
13n

1k
1W
1n
2c
2A
3l
4k
4m

2q
2j
2e
3q
4
5
6W
6W

1
1i
1c
1f
2a
3
4b
4b

3j
3n
4l
5j
6d
8l
10g
10g

4.4
8.0
13.0
23.6
45.0
88.0
110.0
110.0

LR Threaded Aluminum
Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

F

G

H

CI

CI

ALR1
ALR2
ALR3
ALR4
ALR5
ALR6
ALR7
ALR8
ALR9
ALR10

d
f
1
1b
1d
2
2d
3
3d
4

3g
4e
5c
7b
7b
9d
12b
12b
15
15

3d
4a
4g
6d
6d
8l
11b
11b
14k
14k

4j
5a
5j
7g
7g
10i
13
13
16b
16b

1j
1w
1f
2d
2d
3a
4d
4d
5d
5d

1c
1e
1g
2f
2f
3k
4d
4d
5d
5d

3l
4a
4g
6j
6j
8i
10b
10b
12f
12f

2
2j
2d
3c
3c
3n
5d
5d
6d
6d

A
g
1
1d
1d
1n
2g
2g
3
3

4.3
7.3
11.8
32.0
32.0
69.5
190.0
190.0
366.0
366.0

4.8
7.5
12.5
36.5
36.5
73.8

LRL Style
Only

LR EMT Aluminum

LR Threaded Aluminum
and EMT Aluminum

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

F

G

H

CI

BLR1
BLR2
BLR3
BLR4
BLR5
BLR6

d
f
1
1b
1d
2

3g
4e
5c
7b
7b
9d

3d
4a
4g
6d
6d
8l

4j
5a
5j
7g
7g
10i

1j
1w
1f
2d
2d
3a

1c
1e
1g
2f
2f
3k

3l
4a
4g
6j
6j
8i

2
2j
2d
3c
3c
3n

A
g
1
1d
1d
1n

4.3
7.3
11.8
32.0
32.0
69.5

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

Style
CI LRLOnly

4.8
7.5
12.5
36.5
36.5
73.8

A47

T&B ® Fittings

Form 7, Form 8, and Red•Dot Conduit Outlet Bodies

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 48

T&B ® Fittings

A
Form 7, Form 8, and Red•Dot® Conduit Outlet Bodies
®
®

X Form 7

D

C

E

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

CI

X17
X27
X37
X47
X57
X67

d
f
1
1b
1d
2

5.60
6.20
7.35
7.30
8.60
9.50

1.80
2.00
2.30
2.30
2.60
3.20

3.05
3.30
3.80
3.85
5.05
5.45

.95
1.15
1.35
1.80
2.05
2.45

3.20
3.80
4.55
5.00
5.45
6.40

6.0
9.1
16.9
19.3
27.5
52.8

®
®

B

X Form 8

A
X Form 7 and Form 8

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

CI

X18
X28
X38
X48
X58
X68

d
f
1
1b
1d
2

5L
6s
7j
8d
10c
12b

1f
2
2b
2e
2v
3l

2C
3h
3d
4a
5b
6b

1
1c
1c
1f
2a
3

3j
3n
4l
5j
6d
8l

6.0
9.0
15.0
24.0
46.5
88.0

®

C

D

®

L Form 7
E

B
A

Dimensions (in.)

Cat.
No.
L17-TB
L27-TB
L37-TB
L47-TB
L57-TB
L67-TB

Size

A

B

C

D

E

d
f
1
1b
1d
2

4.60
5.25
6.00
6.45
7.90
8.30

1.40
1.60
1.90
2.30
2.60
3.20

1.45
1.65
2.60
3.05
3.80
4.25

.95
1.15
1.35
1.80
2.05
2.45

3.20
3.80
4.55
5.00
5.45
6.40

L Form 7

L Threaded Aluminum
Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

F

G

H

CI

CI

ALRL1
ALRL2
ALRL3
ALRL4
ALRL5
ALRL6

d
f
1
1b
1d
2

3g
4e
5c
7b
7b
9d

3d
4a
4g
6d
6d
8l

4j
5a
5j
7g
7g
10i

1j
1w
1f
2d
2d
3a

1c
1e
1g
2f
2f
3k

3l
4a
4g
6j
6j
8i

2
2j
2d
3c
3c
3n

A
g
1
1d
1d
1n

4.3
7.3
11.8
32.0
32.0
69.5

4.8
7.5
12.5
36.5
36.5
73.8

LRL Style
Only

L EMT Aluminum
Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

F

G

H

CI

CI

BLRL1
BLRL2
BLRL3
BLRL4
BLRL5
BLRL6

d
f
1
1b
1d
2

3g
4e
5c
7b
7b
9d

3d
4a
4g
6d
6d
8l

4j
5a
5j
7g
7g
10i

1j
1w
1f
2d
2d
3a

1c
1e
1g
2f
2f
3k

3l
4a
4g
6j
6j
8i

2
2j
2d
3c
3c
3n

A
g
1
1d
1d
1n

4.3
7.3
11.8
32.0
32.0
69.5

4.8
7.5
12.5
36.5
36.5
73.8

LRL Style
Only

LRL Threaded Aluminum and
EMT Aluminum

A48

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 49

A
®

T&B ® Fittings

Form 7, Form 8, and Red•Dot Conduit Outlet Bodies
E Form 7
E
C

D

B
A

Size

A

B

C

D

E

CI

E17
E27
E37

d
f
1

4.60
5.25
6.00

1.40
1.60
1.90

1.45
1.65
1.80

.95
1.15
1.35

3.20
3.80
4.55

6.0
9.1
16.9

E Threaded Aluminum
Cat.
No.

E Form 7

Dimensions (in.)

Cat.
No.

AE-1
AE-2
AE-3

Dimensions (in.)
Size

A

B

C

D

E

F

G

CI

d
f
1

3g
4e
5c

4c
5a
5n

1Q
1w
1f

1c
1e
1g

2u
2A
3b

2h
2X
2e

m
n
1

4.3
7.3
11.8

®
®

B

A

C

D

TB Form 8
Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

CI

TB18
TB28
TB38
TB484
TB58
TB68

d
f
1
1b
1d
2

5W
6s
7j
8d
10c
12b

2e
2g
3b
3j
3W
4b

1c
1i
1f
2i
2f
3f

1
1i
1c
1f
2a
3

3j
3n
4l
5j
6d
8l

6.0
9.0
15.0
24.0
46.5
88.0

E
TB Form 8

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A49

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 50

T&B ® Fittings

A
Mogul Conduit Outlet Bodies
Application
Mogul bodies are installed in conduit systems to:
• Act as pull outlets for conductors that are stiff, due to large size or type of insulation.
• Provide the longer openings needed when pulling large conductors.
• Prevent sharp bends and kinks in large conductors (protects insulation during
installation.)
• Provide ample openings for splices and taps.
• Provide access to wiring for maintenance, and future system changes.
Features
Mogul bodies have:
• Long openings.
• Provision for easy bends.
• Tapered tapped hubs with integral bushings.
• Stainless Steel cover screws.
• Covers and gaskets included.
Standard Materials
• Class 30 Gray iron alloy.
Standard Finishes
• Electrogalvanized and aluminum acrylic paint.
Certifications and Compliances:
• UL Standard: 514B
• Fed. Spec.: W-C-586d
• CSA Standard: C22.2 No.18
• UL listed for wet locations.
®
®

BC Mogul Series

C

E
A

B

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

CI

BC3-TB
BC4-TB
BC5-TB
BC6-TB
BC7-TB
BC8-TB
BC9-TB
BC10-TB

1
1b
1d
2
2d
3
3d
4

9.56
9.56
13.75
13.75
18.38
18.38
23.75
23.75

1.88
2.31
2.56
3.31
3.63
4.38
4.88
5.38

2.25
2.25
3
3
4.25
4.25
5.25
5.25

7.84
7.84
11.45
11.45
15.61
15.82
20.50
20.50

6
6
10
10
15
15
20
20

20.0
25.0
60.0
78.0
180.0
225.0
410.0
460.0

SECTION A-A

D

BC
®
®

BLB† Mogul Series

E

C

A

Dimensions (in.)

Cat.
No.

Size

A

B

BLB3-TB
BLB4-TB
BLB5-TB
BLB6-TB
BLB7-TB
BLB8-TB
BLB9-TB
BLB10-TB

1
1b
1d
2
2d
3
3d
4

8.66
8.66
12.58
12.58
16.94
16.94
22.16
22.16

2.80
2.70
2.56
4.16
5.10
5.81
6.50
7.00

C
2.25
2.25
3
3
4.25
4.25
5.25
5.25

D

E

CI

6.92
6.70
10.36
10.13
13.89
13.59
18.32
18.06

6
6
10
10
15
15
20
20

20.0
25.0
62.0
78.0
170.0
210.0
410.0
460.0

B
D
SECTION A-A

D

BLB

A50

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 51

A
®
®

BUB Mogul Series

C

E
A

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

BUB3-TB
BUB4-TB
BUB5-TB
BUB6-TB
BUB7-TB
BUB8-TB
BUB9-TB
BUB10-TB

1
1b
1d
2
2d
3
3d
4

9.49
9.55
16.68
13.68
18.30
18.30
23.74
23.74

2.75
3.21
6.67
4.28
5.03
5.67
6.72
7.22

2.25
2.25
3
3
4.25
4.25
5.25
5.25

7.01
6.71
10.47
10.20
13.97
13.50
18.07
17.73

E

CI

6
6
10
10
15
15
20
20

20.0
25.0
62.0
78.0
170.0
210.0
385.0
430.0

B
SECTION A-A

D

BUB
®
®

BT Mogul Series

C

E
A

B

Dimensions (in.)

Cat.
No.

Size

A

B

C

D

E

CI

BT3-TB
BT4-TB
BT5-TB
BT6-TB
BT7-TB
BT8-TB
BT9-TB
BT10-TB

1
1b
1d
2
2d
3
3d
4

9.56
9.56
13.75
13.75
18.38
18.38
23.75
23.75

1.88
2.31
2.56
3.31
3.63
4.38
4.88
5.38

3.16
3.16
4.06
4.06
5.59
5.72
6.88
6.88

7.84
7.84
11.45
11.45
15.61
15.82
20.50
20.50

6
6
10
10
15
15
20
20

20.0
25.0
62.0
78.0
180.0
225.0
410.0
460.0

SECTION A-A

D

BT

®
®

BG Mogul Series Replacement Covers
Cat.
No.
BG48T-B
BG68-TB
BG88-TB
BG98-TB

A

Dimensions (in.)
Size

A

B

C

D

E

1 to 1b
1d to 2
2d to 3
3d to 4

8.27
12
16.22
21.21

6.62
10.62
12.44
16.63

2.77
3.60
4.97
5.96

.67
.82
.85
.87

–
–
2.75
3.75

B

C

D

SECTION A-A

BG

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A51

T&B ® Fittings

Mogul Conduit Outlet Bodies

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 52

T&B ® Fittings

A
Aluminum Mogul Conduit Outlet Bodies

Meets NEC Article 370-28,
6-1 Ratio
Suitable for use in
Wet Locations

NEMA 3R

®
®

Application
• Raintight junction for bringing electrical service into a location.
• Spacious, accessible wiring chamber provides a convenient
location to pull conductors and make splices.

MALB

Precision
machined
threads
Copper-free
aluminum

Standard Materials
• Mogul Pulling Elbows: Die cast aluminum alloy A360 with less
than .004 copper content (copper-free). Stainless steel screws.
• Gaskets: Composition
Standard Finish
• Aluminum lacquer finish

Clean
cover
edges

Deep
slotted
stainless
steel
screws

Strong
“I” beam
construction
®
®

Smooth
conduit
stops

Features/Benefits
• Copper-free* aluminum provides increased corrosion resistance.
• Precision cast and machined surfaces permit safer wire pulling.
• Clean cover edges provide good gasket sealing.
• Precision NPT threaded hubs allow trouble-free field installation
for rigid and IMC conduit.
• Deep slotted stainless steel cover screws for faster installation.
• Clear UL, CSA and cubic content markings speed approval by
inspectors.
• Dome style cover permits easy wire pulling.
• Meets NEC Article 370-28, 6-1 ratio.

Clear
markings

Compliances
• UL Listed
• CSA Certified
• Federal Spec. W-C-586
• NEC Article 370-28
Sample Specifications
• Mogul Pulling Elbows shall be die cast copper-free* aluminum
alloy A360. All conduit stops shall be coined and free of rough
edges. Mogul Pulling Elbows shall be finished with aluminum
lacquer.
Mogul Pulling Elbows shall be Red•Dot® Catalog No. __________
*Less than .004 copper content

Large
dome
cover

A52

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 53

Aluminum Mogul Conduit Outlet Bodies

NEMA 3R

A

Complete with Cover, Gasket and Screws – Raintight
Cat.
No.

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

MALB-3
MALB-4
MALB-5
MALB-6

1"
1b"
1d"
2"

1
2
1
1

10
10
1
1

174
160
400
375

Cat.
No.

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

MALB-7
MALB-8
MALB-9
MALB-10

2d'
3"
3d"
4"

1
1
1
1

1
1
1
1

1100
1060
1900
1800

Cat.
No.

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

1" or 1b"
1d" or 2"
2d" or 3"
3d" or 4"

1
1
1
1

5
5
5
5

3
4
5
5

MALB-3 through -6

MALB-7 through -10

MGKV-4
MGKV-5
MGKV-6
MGKV-7

MGKV-4 through -7

MALB

A
B
G

DE

C

Size

A

B

C

D

E

F

G

1"
1b"
1d"
2"
2d"
3"
3d"
4"

9e
9e
14w
14w
21W
21W
28e
28e

9h
9h
14b
14b
21u
21u
28W
28W

2d
2d
2f
2f
4d
4d
5d
5d

2f
2f
4
4
5e
5e
6d
6d

2h
2h
2m
2m
4c
4c
5c
5c

8d
8d
13
13
18
18
24
24

3e
3e
5r
5r
7z
7z
9z
9z

F
MALB

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A53

T&B ® Fittings

Meets NEC Article 370-28,
6-1 Ratio
Suitable for use in
Wet Locations

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 54

T&B ® Fittings

A
FS/FD Cast Device Boxes and Covers
®
®

Application
Cast device boxes are installed to:
• Accommodate wiring devices.
• Act as pull boxes for conductors in a threaded rigid conduit system, including
an internal ground screw.
• Provide openings to make splices and taps in conductors.
• Provide access to conductors for maintenance and future system changes.
• Connect conduit sections.

A

Dead-End
C

E

B

F

A
G

Features
All hubs have NPT Threads with a minimum of five full threads and integral
bushing. Internal grounding screw standard on boxes.
• Suitable for wet locations when used with gasketed covers.
• Available in shallow (FS) or deep (FD) boxes. Use FD if device to be enclosed
exceeds 1e" in depth.
• Use blank bodies where special arrangements of conduit hubs or entrances
are required.
• All cover holes are #6-32.
• Mounting lugs are standard on all FS and FD boxes.
Size Range
• Hubs - d" to 1" NPT
Materials
• Boxes: Class 30 Gray iron alloy
• Covers: Sand cast AL alloy and sheet steel
• Gaskets: Neoprene

B

Finish
• Zinc-plated with aluminum acrylic paint
Dead-End
D

Listing Certifications
• UL: 514A (wet locations when used with gasketed covers)
• CSA: C22.2 No.18

C

B

E

Shallow Single Gang Cast Device Boxes
Cat.
No.

A

Dead-End
FS019-TB
FS1-TB
FS2-TB
FS3-TB
Thru-Feed
FSC1-TB
FSC2-TB
FSC3-TB

C

Dimensions (Inches)

Throat Dia.

Fig.

Hub
Size

A

B

C

D

E

F

G

Min.

Max.

A
B
B
B

Blank
d
f
1

2
2
2
2

2f
2f
2f
2f

4s
4s
4s
4s

–
g
g
g

3c
2i
2i
2i

4z
–
–
–

g
–
–
–

N/A
0.570
0.755
0.935

N/A
0.610
0.810
1.035

C
C
C

d
f
1

2
2
2

2f
2f
2f

4s
4s
4s

g
g
g

2i
2i
2i

5c
5c
5c

–
–
–

0.570
0.755
0.935

0.610
0.810
1.035

Deep Single Gang Cast Device Boxes
Cat.
No.

Thru-Feed
D

C

E

B

F
A

A54

Dead-End
FD019-TB
FD1-TB
FD2-TB
FD3-TB
Thru-Feed
FDC1-TB
FDC2-TB
FDC3-TB

Dimensions (Inches)

Throat Dia.

Fig.

Hub
Size

A

B

C

D

E

F

G

Min.

Max.

A
B
B
B

Blank
d
f
1

2m
2m
2m
2m

2f
2f
2f
2f

4s
4s
4s
4s

–
g
g
g

3c
2i
2i
2i

4z
–
–
–

1c
–
–
–

N/A
0.570
0.755
0.935

N/A
0.610
0.810
1.035

C
C
C

d
f
1

2m
2m
2m

2f
2f
2f

4s
4s
4s

g
g
g

2i
2i
2i

5c
5c
5c

–
–
–

0.570
0.755
0.935

0.610
0.810
1.035

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 55

A

Shallow Double Gang Cast Device Boxes
A

Cat.
No.

Dead-End
C

B

E

Dimensions (Inches)

Throat Dia.

Fig.

Hub
Size

A

B

C

D

E

F

Min.

Max.

Dead-End
FS062-TB
FS12-TB
FS22-TB
FS32-TB

A
B
B
B

Blank
d
f
1

2
2
2
2

4e
4e
4e
4e

4s
4s
4s
4s

–
g
g
g

4a
2i
2i
2i

5d
–
–
–

N/A
0.570
0.755
0.935

N/A
0.610
0.810
1.035

Thru-Feed
FSC12-TB
FSC222-TB
FSC32-TB

C
C
C

d
f
1

2
2
2

4e
4e
4e

4s
4s
4s

g
g
g

2i
2i
2i

5c
5c
5c

0.570
0.755
0.935

0.610
0.810
1.035

Deep Double Gang Cast Device Boxes

F
A

Cat.
No.

B

Dimensions (Inches)

Throat Dia.

Fig.

Hub
Size

A

B

C

D

E

F

Min.

Max.

Dead-End
FD062-TB
FD12-TB
FD22-TB
FD32-TB

A
B
B
B

Blank
d
f
1

2m
2m
2m
2m

4e
4e
4e
4e

4s
4s
4s
4s

–
g
g
g

4a
2i
2i
2i

5d
–
–
–

N/A
0.570
0.755
0.935

N/A
0.610
0.810
1.035

Thru-Feed
FDC12-TB
FDC222-TB
FDC32-TB

C
C
C

d
f
1

2m
2m
2m

4e
4e
4e

4s
4s
4s

g
g
g

2i
2i
2i

5c
5c
5c

0.570
0.755
0.935

0.610
0.810
1.035

Dead-End
C

D

Double Gang Cast Device Boxes, Double Hub
E

B

A

Dimensions (Inches)

Throat Dia.

Cat.
No.

Fig.

Hub
Size

A

B

C

D

E

Min.

Max.

FSS222-TB

D

f

2

4e

4s

g

4h

0.755

0.810

FDS222-TB

D

f

2m

4e

4s

g

4h

0.755

0.810

D
C

Dead-End
Thru-Feed
D

D

C

B

E

C

E

B

F
A
A

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A55

T&B ® Fittings

FS/FD Cast Device Boxes and Covers

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 56

T&B ® Fittings

A
FS/FD Cast Device Boxes and Covers
1.405 dia. hole

Single Gang Covers

DSS100-TB

Cat. No.

Description

DSS100-TB
DS21-TB
DS23-TB
DS32-TB
DS100G-TB

Blank, Sheet Steel
Round Receptacle, Sheet Steel
Duplex Receptacle, Sheet Steel
Single Switch, Sheet Steel
Blank, Cast Aluminum

DS21-TB

Double Gang Covers

DS23-TB

Cat. No.

Description

S1002-TB
S32232-TB
S32212-TB
S232-TB
S322-TB
S1002GSA-TB

Blank, Sheet Steel
2 Receptacle/Switch, Sheet Steel
Single Receptacle/Switch, Sheet Steel
2 Dual Receptacle, Sheet Steel
2 Switch, Sheet steel
Blank, Cast Aluminum with Gasket

DS32-TB

1.405 dia. hole

S1002-TB

S32232-TB

S32212-TB

S232-TB

DS100G-TB

S322

A56

S1002GSA-TB

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 57

A

Application
• Industrial grade FS device boxes and raintight covers protect wiring devices,
switches, electronic components, and terminal blocks in Dry, Damp and Wet
Locations.
• Spacious, accessible wiring chamber provides a convenient location to maintain or change a system, pull conductors and make splices.
• Junction for branch conduits.
• Aluminum boxes can be used with steel rigid conduit.
AFS

2AFSC

CWP-G

Features/Benefits
• Copper-free* aluminum, stainless steel cover springs and hinge pins provide
increased corrosion resistance.
• Die cast construction, boxes with securely fastened mounting plates and
industrial designed covers combine to produce a rugged protective enclosure
for devices on industrial and OEM applications.
• Clean cover edges provide good gasket sealing.
• Precision NPT threaded hubs allow trouble-free field installation for rigid or
IMC conduit.
• Clear UL, CSA and cubic content markings speed approval by inspectors.
• Boxes - external hub design provides increased wiring room.

CDR

Standard Materials
• Die cast aluminum alloy A360 with less than .004 copper content (copper-free).
• Cover hinge pins and springs: Stainless steel.
Standard Finish
• Aluminum lacquer finish.
Compliances:
• UL Listed
• Boxes CSA Certified with factory installed ground screw **
• Covers CSA Certified
• Federal Spec. W-C-586

High
quality
gaskets

Stainless
steel
springs
Smooth
conduit
stops

Sample Specifications
• Industrial grade FS device boxes and covers shall be die
cast copper-free* aluminum alloy A360. All conduit stops
shall be coined and free of rough edges. Raintight covers
shall have stainless steel springs and hinge pins and are
suitable for use in wet locations with cover closed (CFSB,
CFST and CFSTF suitable for wet locations). Industrial grade
FS device boxes and covers shall be finished with aluminum
lacquer. Industrial grade FS device boxes and covers shall
be Red•Dot® Catalog No. _______
**Less than .004 copper content
**Consult factory for lead time and minimum quantity.

Precision
machined
threads

Copper-free*
aluminum

Clear
marking

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A57

T&B ® Fittings

FS/FD Aluminum Device Boxes and Covers

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 58

Suitable for use
in Wet Locations
NEMA 3R

T&B ® Fittings

A
FS/FD Aluminum Device Boxes and Covers
Single Gang Boxes *Raintight
Cat.
No.

AFS

AFSC

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

5
5
5

25
25
25

68
74
72

5
5
5

25
25
25

72
88
79

5
5

25
25

80
76

5
5

25
25

88
80

5
5
5

74
78
80

5
5
5

76
90
90

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

Standard, 1 Hole Box, Dead End
* 2AFS-1
d"
* 2AFS-2
f"
* 2AFS-3
1"

2
2
2

10
10
10

115
95
90

Standard, 2 Hole Box, Through Feed
* 2 AFSC-1
d"
* 2AFSC-2
f"

2
2

10
10

104
102

3
3
3

128
143
129

Standard, 1 Hole Box, Dead End
* AFS-1
d"
* AFS-2
f"
* AFS-3
1"
Standard, 2 Hole Box, Through Feed
* AFSC-1
d"
* AFSC-2
f"
* AFSC-3
1"
Standard, 2 Hole Box, Dead End
* AFSS-1
d"
* AFSS-2
f"
Standard, 3 Hole Box, Through Feed
* AFSCC-1
d"
* AFSCC-2
f"

AFSS

AFSCC

Deep, 1 Hole Box, Dead End
* ADFS-1
d"
* ADFS-2
f"
* ADFS-3
1"
Deep, 2 Hole Box, Through Feed
* ADFSC-1
d"
* ADFSC-2
f"
* ADFSC-3
1"
*Raintight when used with appropriate Red•Dot® covers.

Two Gang Boxes *Raintight
Cat.
No.

ADFS

ADFSC

Hub
Size

Deep, 1 Hole Box, Dead End
* 2ADFS-1
d"
* 2ADFS-2
f"
* 2ADFS-3
1"
*Raintight when used with appropriate Red•Dot® covers.
2AFS

2AFSC

Multi-Gang Boxes *Raintight
Cat.
No.
FSMG-TB

Hub
Size

Std.
Pkg.

Wt. lbs.
per 100

4" threadless Conduit

1

242

*Raintight when used with appropriate Red•Dot® covers.

2ADFS

A58

FSMG-TB

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 59

FS/FD Aluminum Device Boxes and Covers

Single Gang Covers Complete with Gasket and
Screws *Raintight
Cat.
No.
CWPDR

CWPDR-FS

CWPV-DR

CFSDR

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

For Duplex Receptacles, Horizontal
* CWPDR
Duplex receptacle cover with 2 spring doors, Device Mount
* CWPDR-FS
Box Mount

1
1

25
25

40
40

For Duplex Receptacles, Vertical
* CFSDR
Box Mount

1

25

38

For GFCI Receptacles Horizontal
* CFSH-G
Box Mount

1

25

40

1

25

40

1

25

40

Description

For GFCI Receptacles Vertical
* CWPV-G
GFCI receptacle cover 2y” x 1X” rectangular opening
Device Mount
* CFSR-G
Box Mount
*Raintight when used with appropriate Red•Dot boxes.
®

CWP-G

CFSH-G

CWPV-G

CFSR-G

Cat.
No.

CFSR Series

Nominal
Size

Max. Device
Face Dia.

For Single Receptacles Vertical (Box Mount Only)
* CFSR-L
1l"
1.600”
* CFSR-S
1c"
1.395”
* CFSR-X
1B"
1.865”
* CFSR-XL
2a"
2.145”
* CFSR-Y
1f"
1.750

Unit
Qty.

Std.
Pkg.

Wt. lbs
per 100

1
1
1
1
1

25
25
25
25
25

40
40
40
40
40

*Raintight when used with appropriate Red•Dot® boxes.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A59

A
T&B ® Fittings

Suitable for use in
Wet Locations with Cover
Closed NEMA 3R

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 60

T&B ® Fittings

A
FS/FD Aluminum Device Boxes and Covers
Single Gang Covers Complete with Gasket and Screws
*Raintight
Cat.
No.

CFSTF

CFST

Unit
Qty.

Description

Std.
Pkg.

Wt. lbs.
per 100

Switch Cover
* CFST

Plunger Style, Switch Cover, Box Mount NEMA 3R

1

25

40

Switch Cover
* CFSTF

Front Lever, Switch Cover, Box Mount NEMA 4

1

25

40

Blank Cover
* CFSB

Blank Cover, Box Mount, NEMA 3R

20

100

14

*Raintight when used with appropriate Red•Dot boxes.
®

CFSB

Suitable for use in
Wet Locations with Cover
Closed NEMA 3R

FS/FD Aluminum Device Boxes and Covers

Two Gang Covers Complete with Gasket and Screws
*Raintight
Cat.
No.

2CWPDR

2CWPR-M

2CWTDR

2CFSR-M

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

1

10

48

1

10

48

For Single Receptacle
* 2CWPR-M
Single Receptacle Cover, Hole Dia. 2b”, Device Mount
* 2CFSR-M
Single Receptacle Cover, Hole Dia. 2b”, Box Mount

1
1

10
10

48
48

For Two Switches
* 2CFST
Plunger Style Switch Cover, Box Mount

1

10

26

Blank
* 2CFSB

10

50

25

Description

For Two Duplex Receptacles
* 2CWPDR
Two Duplex Receptacle Cover with 2 Spring Doors,
Device Mount
For Switch and Duplex Receptacle
* 2CWTDR
Switch and Duplex Receptacle Cover, Box/Device Mount

Blank Cover, Box Mount

*Raintight when used with appropriate Red•Dot boxes.
®

2CFST

A60

2CFSB

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 61

A

Single Gang Covers Complete with Gasket and Screws
Cat.
No.

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

20

100

11

20

100

14

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

20
20
20

100
100
100

12
12
12

Description

Std.
Pkg.

Wt. lbs.
per 100

Composition Gasket

100

2

Description

For Duplex Receptacles
CDR
Duplex receptacle Cover, Box Mount
For Switches
CTS
Switch Cover, Box Mount

CDR

CTS

Cat.
No.

Nominal
Size

Max. Device
Face Dia.

For Single Receptacles (Box Mount Only)
CRL
1l"
1.600”
CRS
1c"
1.395”
CRX-L
2a"
2.145”
Cat.
No.
Gasket
FS-GKV

CR Series

FS-GKV

Two Gang Covers Complete with Gasket and Screws
Cat.
No.

2CDR

2CTDR

2CTS

Description

For Two Duplex Receptacles
2CDR
Two Duplex Receptacle Cover, Device Mount
For Two Switches
2CTS
Switch Cover, Device Mount
For Switch and Duplex Receptacles
2CTDR
Switch and Duplex Receptacle Cover, Device Mount
Gasket
2FS-GKV
Composition Gasket

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

10

50

24

10

50

24

10

50

24

50

3

2FS-GKV

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A61

T&B ® Fittings

FS/FD Aluminum Device Boxes and Covers

412031.A01 FIT 3/12

3/13/03

4:46 PM

Page 62

T&B ® Fittings

A
FS/FD Aluminum Device Boxes and Covers
Dimensions and Cubic Inches (CI) Single Gang Boxes

AFS

AFSC

AFSS

AFSCC

AFS, AFSC, AFSS, AFSCC

Cat.
No.
AFS-1
AFS-2
AFS-3
AFSC-1
AFSC-2
AFSC-3
AFSS-1
AFSS-2
AFSCC-1
AFSCC-2

Hub
Size

A

B

C

D

E

F

G

H

d"
f"
1”
d"
f"
1"
1d"
f"
d"
f"

4l
4l
4l
4l
4l
4l
4l
4l
4l
4l

2m
2m
2m
2m
2m
2m
2m
2m
2m
2m

m
m
m
m
m
m
m
m
m
m

2h
2h
2h
2h
2h
2h
2h
2h
2h
2h

1a
1L
1L
1a
1L
1L
1c
1c
1c
1c

2g
2g
2g
2g
2g
2g
2g
2g
2g
2g

2l
2l
2l
2l
2l
2l
2l
2l
2l
2l

1n
1n
1n
1n
1n
1n
1n
1n
1n
1n

ADFS

J

CI

1d
1d
1d
1d

21.6
21.6
21.6
21.6
21.6
21.6
21.6
21.6
21.6
21.6

ADFSC

ADFS, ADFSC

Cat.
No.
ADFS-1
ADFS-2
ADFS-3
ADFSC-1
ADFSC-2
ADFSC-3

A62

Hub
Size

A

B

C

D

E

F

G

H

CI

d"
f"
1"
1d"
f"
1"

4l
4l
4l
4l
4l
4l

2m
2m
2m
2m
2m
2m

g
g
g
g
g
g

3h
3h
3h
3h
3h
3h

1a
1L
1L
1a
1L
1L

2g
2g
2g
2g
2g
2g

2l
2l
2l
2l
2l
2l

2n
2n
2n
2n
2n
2n

31.3
31.3
31.3
31.3
31.3
31.3

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 63

A
T&B ® Fittings

FS/FD Aluminum Device Boxes and Covers
Dimensions and Cubic Inches (CI) Two Gang Boxes

2AFS

2AFSC

2AFS, 2AFSC

Cat.
No.
2AFS-1
2AFS-2
2AFS-3
2AFSC-1
2AFSC-2

Hub
Size

A

B

C

D

E

F

G

H

CI

d"
f"
1"
d"
f"

4l
4l
4l
4l
4l

4e
4e
4e
4e
4e

m
m
g
m
m

2h
2h
2h
2h
2h

1c
1c
1L
1c
1c

2g
2g
2g
2g
2g

4c
4c
4c
4c
4c

1n
1n
1n
1n
1n

36.0
36.0
36.0
36.0
36.0

2ADFS

2ADFSC
2ADFS, 2ADFSC

Cat.
No.
2ADFS-1
2ADFS-2
2ADFS-3
2ADFSC-2
2ADFSC-3

Hub
Size

A

B

C

D

E

F

G

H

CI

d"
f"
1”
f"
1"

4l
4l
4l
4l
4l

4e
4e
4e
4e
4e

m
m
g
m
g

3p
3p
3p
3p
3p

1c
1c
1L
1c
1L

2g
2g
2g
2g
2g

4c
4c
4c
4c
4c

2O
2O
2O
2O
2O

54.0
54.0
54.0
54.0
54.0

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A63

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 64

T&B ® Fittings

A
FS/FD Aluminum Device Boxes and Covers
Dimensions Single Gang Covers

CWPDR

CFSDR

CWPV-G

CFST

A64

CWPDR-FS

CDR

CFSR-G

CTS

CWPV-DR

CWP-G

CFSR Series

CFSTF

CFSH-G

CR Series

CFSB

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 65

A
T&B ® Fittings

FS/FD Aluminum Device Boxes and Covers
Dimensions Two Gang Covers

1m"

1m"

4e"

4e"

4e"

4l"

4l"

4l"

3L"

2CWPDR

2CDR

4e"

4e"

l"

2CTDR

4e"

3L"

4l"

2b"

2b"

Dia.

Dia.

4l"

2c"

3L"

1m"

3f"
2CWTDR

2CFSR-M

4e"

4e"

4l"

2CWPR-M

3L"

4l"

3f"
2CFST

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

4e"

3L"

4l"

3L"

3f"

3f"

2CTS

2CFSB

www.tnb.com

A65

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 66

T&B ® Fittings

A

New

Conduit Expansion Coupling

XJG-TB Rigid Conduit Expansion Coupling
No Disassembly Required.

8" Movement

Gland
Nut

Internal Bonding
Jumper

Whenever you install a rigid
expansion coupling in a long conduit run, you normally need three
hands, two strong backs and lots
of patience. Now you can relax.
T&B introduces the new, no-hassle Rigid Conduit Expansion
Coupling. Installation’s just a few
turns and you’re done. The T&B
Rigid Conduit Expansion Coupling
features innovations that provide
conveniences to the installer, saving time and money on the job.
There’s no disassembly needed
during the installation, requiring
fewer tools and less opportunities
for lost pieces.
The new XJG-TB Rigid Conduit
Expansion Coupling also packs an

added punch: It’s the only fitting of
its kind that features a true internal
bonding jumper. This eliminates
the need for additional external
bonding jumpers, so there’s fewer
parts to buy and install.
If you need a fitting that can give
and take without a lot of hassle,
reach for T&B’s new XJG-TB Rigid
Conduit Expansion Coupling. It’s
the latest breakthrough in the
industry’s leading line of conduit
fittings. Contact your local representative for more information
regarding the XJG-TB Rigid
Conduit Expansion Coupling and
the complete line of conduit fittings from the name you trust for
quality design and manufacturing,
Thomas & Betts.

Bonding
Bushing

Internal Sliding
Bushing (keyed)

4" Movement

1

Slide the fitting onto the conduit
until it stops at the internal sliding
bushing. Tighten and you’re
ready. No parts to reassemble!

Innovative Design Makes
Installations Easier.
• No disassembly necessary to install
• Fast, simple, and requires fewer steps
• True Internal Bonding Jumper - no
external grounding strap required
• Tamper-proof internal jumper protected
from the environment
• Exceeds code requirements for long
conduit runs to permit linear movement

A66

2
With a wrench, tighten the gland
nut to compress the Teflon packing, creating a rain-tight seal
around the conduit.

3
Thread the next length of conduit
into the other end of the fitting
and tighten. You’re done!

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/20/03

3:17 PM

Page 67

A
T&B ® Fittings

Conduit Expansion Coupling
B

C

A

XJG Conduit Expansion Coupling
Cat No.

Size

Movement

A
Diameter

XJG24-TB
XJG28-TB
XJG34-TB
XJG38-TB
XJG44-TB
XJG48-TB
XJG54-TB
XJG58-TB
XJG64-TB
XJG68-TB
XJG74-TB
XJG78-TB
XJG84-TB
XJG88-TB
XJG94-TB
XJG98-TB
XJG104-TB
XJG108-TB
XJG1208-TB

f"
f"
1"
1"
1b"
1b"
1d"
1d"
2"
2"
2d"
2d"
3"
3"
3d"
3d"
4"
4"
5"

4"
8"
4"
8"
4"
8"
4"
8"
4"
8"
4"
8"
4"
8"
4"
8"
4"
8"
8"

2.43
2.43
2.67
2.67
3.36
3.36
3.36
3.36
3.86
3.86
4.96
4.96
4.96
4.96
6.37
6.37
6.37
6.37
7.99

Suggested Specifications
B
Length

C
Height

10.00
14.00
10.00
14.00
10.56
14.56
10.56
14.56
11.25
15.25
12.12
16.12
12.12
16.12
12.87
16.87
12.87
16.87
18.87

2.75
2.75
2.99
2.99
3.68
3.68
3.68
3.68
4.18
4.18
5.25
5.25
5.25
5.25
6.75
6.75
6.75
6.75
8.56

Please consult Technical Services for special orders and availability of products not shown in
this list.

Listed / Certified By:
®
®

UL

(File E23018, Std. 514B)
Suitable for Wet Locations

CSA

(File LR2884, Std. C22.2 No. 18)

Expansion Fittings for Rigid Steel or Intermediate Metal Conduit
Where raceways require expansion fittings to compensate for
thermal expansion and contraction and where expansion fittings
and telescoping sections of metal raceway shall be made electrically continous by bonding jumpers or other means:
• Fitting will be constructed from malleable or ductile iron with
exterior and interior zinc plating for corrosion protection.
• The fitting shall be constructed so that disassembly is not
required during installation.
• Fitting shall be raintight after installation.
• The fitting shall have an internal bonding jumper constructed of
a tinned copper braid, sized to meet UL fault current test requirements and comply with bonding requirements - NEC article
250.98
• External bonding jumper shall not be required to comply with
NEC requirements.
• Accepted Manufacturers: Thomas & Betts - XJG-TB Series

Standard Materials / Finish
Body . . . . . . . . . . . . . . . . . Malleable or Ductile Iron,
available PVC Coated
Internal Bonding Jumper . . . Tinned Copper Braid
Exterior and Interior Finish . Zinc Plating, Aluminum Acrylic Paint
Packing . . . . . . . . . . . . . . . . PTFE/Synthetic Fiber Material
(Teflon®) Coated)

Our complete line makes specifying easy too.
Thomas & Betts offers a wide variety of quality fittings suitable
for outdoor use and hazardous locations.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A67

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 68

T&B ® Fittings

Conduit Outlet Boxes
Explosionproof, Dust-Ignitionproof

C

B
A

C

B
A

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

A

Application
GUA boxes can be used for hazardous location conduit runs for the
following:
• Allows for mounting of fixture outlets
(when used with appropriate covers).
• Provides easy access to wiring.
• Provides junction in conduit for wire
pulling and splices.
• Changes direction in rigid conduit
systems.
• Attaches two or more pieces of conduit in long runs.
• Guards against damage to wires in
rigid conduit.
Features
• All hubs have a minimum of five full
threads and integral bushing.
• All boxes are furnished with internal
grounding screw.
• Cover supplied with “O” ring gasket.

Size Range
• d" NPT to 2" NPT
• Access opening 2" to 5" diameter
Materials
• Bodies: Grade 60-45-10 Ductile Iron
(Complies with ASTM standard
A536)
• Covers: Die cast aluminum
Finish
• Boxes: Zinc-plated with aluminum
acrylic paint
• Covers: Natural
Listing Certifications
• UL514A (wet locations when used
with gasketed covers)
• UL886
• CSA: C22.2 No. 30
®
®

GUA Conduit Outlet Boxes

GUA

GUAB

GUAC

Dimensions (Inches)
B
C

Throat Dia.
Min.
Max.

Cat.
No.

Hub
Size

A

GUA14-TB
GUA16-TB
GUA24-TB
GUA26-TB
GUA36-TB
GUA47-TB
GUA59-TB

d
d
f
f
1
1b
1d

1m
2
2
2
2j
2W
3m

2d
3d
2d
3d
3d
4c
5f

g
g
g
g
g
1
1h

1W
2
1g
2
2j
2z
3J

.570
.570
.755
.755
.935
1.260
1.470

.610
.610
.810
.810
1.035
1.360
1.590

5.5
13.5
5.3
13.3
16.2
29
70

GUAB14-TB
GUAB16-TB
GUAB24-TB
GUAB26-TB
GUAB36-TB
GUAB47-TB
GUAB59-TB
GUAB69-TB
GUAB79-TB

d
d
f
f
1
1b
1d
2
2d

2b
2
2d
2
2j
2W
3m
4h
4h

2d
3d
2d
3d
3d
4c
5f
5f
5f

g
g
g
g
1
1
1h
1h
1a

2ƒ
2
2c
2
2n
2z
3J
4Y
4Y

.570
.570
.755
.755
.935
1.260
1.470
1.880
2.320

.610
.610
.810
.810
1.035
1.360
1.590
2.047
2.380

6.9
13.5
7.9
13.5
15.4
27.5
73.6
80
98

GUAC14-TB
GUAC16-TB
GUAC24-TB
GUAC26-TB
GUAC36-TB
GUAC47-TB
GUAC49-TB
GUAC59-TB
GUAC69-TB

d
d
f
f
1
1b
1b
1d
2

2b
2
2
2
2j
2W
3m
3m
4h

2d
3d
2d
3d
3d
4c
5f
5f
5f

g
g
g
g
g
1
1
1h
1h

2ƒ
2
1g
2
2j
2z
3m
3m
4Y

.570
.570
.755
.755
.935
1.260
1.260
1.470
1.880

.610
.610
.810
.810
1.035
1.360
1.360
1.590
2.047

6.8
13.1
5.3
13.3
16.2
29.3
73.6
74
77.8

GUAD14-TB
GUAD16-TB
GUAD24-TB
GUAD26-TB
GUAD36-TB
GUAD49-TB

d
d
f
f
1
1b

1m
2
2
2
2j
3m

2d
3d
2d
3d
3d
5f

g
g
g
g
g
1

1W
2
1g
2
2j
3m

.570
.570
.755
.755
.935
1.260

.610
.610
.810
.810
1.035
1.360

5.6
12.5
5.2
13.1
16
76

D

Cubic In.
Capacity

GUAD

A68

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 69

Conduit Outlet Boxes
Explosionproof, Dust-Ignitionproof

GUA Conduit Outlet Boxes (continued)

GUAL

GUAM

GUAN

GUAT

GUAW

Dimensions (Inches)
B
C

Throat Dia.
Min.
Max.

Cat.
No.

Hub
Size

A

GUAL14-TB
GUAL16-TB
GUAL24-TB
GUAL26-TB
GUAL36-TB
GUAL47-TB
GUAL49-TB
GUAL59-TB
GUAL69-TB

d
d
f
f
1
1b
1b
1d
2

2b
2
2
2
2j
2W
3m
3m
4h

2d
3d
2d
3d
3d
4c
5f
5f
5f

g
g
g
g
g
1
1
1h
1h

2ƒ
2
1g
2
2j
2z
3J
3J
4Y

.570
.570
.755
.755
.935
1.260
1.260
1.470
1.880

.610
.610
.810
.810
1.035
1.360
1.360
1.590
2.047

7.1
13.4
5.3
13.3
16.2
30
74.5
74
77.8

GUAM14-TB
GUAM16-TB
GUAM24-TB
GUAM26-TB
GUAM36-TB
GUAM47-TB
GUAM69-TB

d
d
f
f
1
1b
2

1m
2
2
2
2j
2W
4h

2d
3d
2d
3d
3d
4c
5f

g
g
g
g
g
1
1h

1W
2
1g
2
2j
2z
4Y

.570
.570
.755
.755
.935
1.260
1.880

.610
.610
.810
.810
1.035
1.360
2.047

5.6
12.5
6.2
12.5
14
29.2
80

GUAN14-TB
GUAN16-TB
GUAN24-TB
GUAN26-TB
GUAN36-TB
GUAN47-TB
GUAN59-TB
GUAN69-TB

d
d
f
f
1
1b
1d
2

2a
2
2j
2
2j
2W
4h
4h

2d
3d
2d
3d
3d
4c
5f
5f

g
g
g
g
g
1
1h
1h

2
2
2i
2
2j
2z
4Y
4Y

.570
.570
.755
.755
.935
1.260
1.470
1.880

.610
.610
.810
.810
1.035
1.360
1.590
2.047

6.8
13.5
7.7
14
16.9
31.5
84
84

GUAT14-TB
GUAT16-TB
GUAT24-TB
GUAT26-TB
GUAT36-TB
GUAT37-TB
GUAT47-TB
GUAT49-TB
GUAT59-TB
GUAT69-TB
GUAT79-TB

d
d
f
f
1
1
1b
1b
1d
2
2d

2b
2
2
2
2j
2j
2W
3m
3m
4h
4h

2d
3d
2d
3d
3d
3d
4c
5f
5f
5f
5f

g
g
g
g
1
g
1
1
1h
1h
1h

2ƒ
2
1g
2
2j
2j
2z
3J
3J
3J
4Y

.570
.570
.755
.755
.935
.935
1.260
1.260
1.470
1.880
2.320

.610
.610
.810
.810
1.035
1.035
1.360
1.360
1.590
2.047
2.380

7
13.5
5.3
13.3
15.9
23.3
29.3
77.2
77.7
77.8
95

GUAW14-TB
GUAW16-TB
GUAW24-TB
GUAW26-TB

d
d
f
f

1m
2
2
2

2d
3d
2d
3d

g
g
g
g

1W
2
1g
2

.570
.570
.755
.755

.610
.610
.810
.810

5.2
13
6.5
13

GUAX14-TB
GUAX16-TB
GUAX24-TB
GUAX26-TB
GUAX36-TB
GUAX37-TB
GUAX47-TB
GUAX49-TB
GUAX59-TB
GUAX69-TB

d
d
f
f
1
1
1b
1b
1d
2

1m
2
2
2
2j
2j
2W
3m
3m
4h

2d
3d
2d
3d
3d
3d
4c
5f
5f
5f

g
g
g
g
1
g
1
1
1h
1h

1W
2
1g
2
2j
2j
2I
3J
3J
4Y

.570
.570
.755
.755
.935
.935
1.260
1.260
1.470
1.880

.610
.610
.810
.810
1.035
1.035
1.360
1.360
1.590
2.047

5.2
13.5
5.3
13.3
16
23.3
30
72
71
77.8

D

Cubic In.
Capacity

GUA Conduit Device Box Replacement Covers
GUAX

Cat.
No.
GUA04-TB
GUA06-TB
GUA07-TB
GUA09-TB

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

Opening
Dia.
2
3
3e
5

www.tnb.com

A69

A
T&B ® Fittings

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 70

T&B ® Fittings

A
Aluminum Conduit Outlet Boxes
Explosion-Proof, Dust-Ignition-Proof

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations
®
®

Application
• Junction for branch conduits in hazardous locations.
• Accessible wiring chamber provides a convenient location to maintain
or change a system, pull conductors and make splices.
• Unique mounting pads and external hub design ideal for installations
of OEM devices or instruments.
GAX

Features/Benefits
• Copper-free* aluminum provides increased corrosion resistance.
• Precision cast and machined surfaces permit safer wire pulling.
• Precision NPT threaded hubs allow trouble-free field installation for
rigid or IMC conduit.
• Die cast construction and industrial design combine to produce a
rugged protective enclosure for devices on industrial and OEM
applications.
• Clear UL, CSA and cubic content markings speed approval by
inspectors.

GAFX

Standard Materials
• Die cast aluminum alloy A360 with less than .004 copper content
(copper-free).
Standard Finish
• Aluminum lacquer finish
Compliances
• UL Listed
• CSA Certified
• Suitable for hazardous locations
• NEMA 4 rated when ordered with O-ring installed
• Federal Spec W-C-586

GAJU

Copper-free
aluminum

Unique
mounting
pads

External
hub design

Sample Specifications
• Outlet boxes for hazardous locations shall be die cast copper- free*
aluminum alloy A360 and suitable for use in Class I, Groups C, D,
Class II, Groups E, F, G and Class III areas. All conduit stops shall be
coined and free of rough edges. Outlet boxes for hazardous locations
shall be finished with aluminum lacquer. Outlet boxes shall be
Red•Dot® Catalog No. __________
*Less than .004 copper content.

Internal
ground
boss and
screw

A70

Smooth
conduit
stops

Precision
machined
threads

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 71

Aluminum Conduit Outlet Boxes
Explosion-Proof, Dust-Ignition-Proof

External Hubs with Installed Green Ground Screw

Through Feed with Surface Cover

GAC

Cat.
No.

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

◗
◗
◗•
◗•
◗•
◗•

d"
f"
1"
1b"
1d"
2"

1
1
1
1
1
1

5
5
5
5
4
4

115
115
115
175
247
253

GAC-1
GAC-2
GAC-3
GAC-4
GAC-5
GAC-6

Dead End with Surface Cover
Cat.
No.
◗• GAE-1
◗• GAE-2
◗• GAE-3

GAE

GAL

GALB

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

d"
f"
1"

1
1
1

5
5
5

110
110
110

L Style with Surface Cover
Cat.
No.

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

◗
◗
◗•
◗•
◗•
◗•

d"
f"
1"
1b"
1d"
2"

1
1
1
1
1
1

5
5
5
5
4
4

115
115
115
175
247
253

GAL-1
GAL-2
GAL-3
GAL-4
GAL-5
GAL-6

LB Style with Surface Cover
Cat.
No.

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

◗
◗
◗
◗•
◗•
◗•

d"
f"
1"
1b"
1d"
2"

1
1
1
1
1
1

5
5
5
5
4
4

115
115
115
175
247
253

GALB-1
GALB-2
GALB-3
GALB-4
GALB-5
GALB-6

T Style with Surface Cover
Cat.
No.

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

◗
◗
◗
◗
◗
◗

d"
f"
1"
1b"
1d"
2"

1
1
1
1
1
1

5
5
5
5
4
4

120
120
120
180
48
406

GAT-1
GAT-2
GAT-3
GAT-4
GAT-5
GAT-6

• Made to order items. Consult factory for lead time and minimum quantities.
◗ Suffix-OR: O-ring available for NEMA 4 rating. Consult factory for lead time and price.
GAT

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A71

A
T&B ® Fittings

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 72

T&B ® Fittings

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

A
Aluminum Conduit Outlet Boxes
Explosion-Proof, Dust-Ignition-Proof

External Hubs with Installed Green Ground Screw and Covers

X Style with Surface Cover

GAX

Cat.
No.

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

†
†
†
†
†
†

d"
f"
1"
1b"
1d"
2"

1
1
1
1
1
1

5
5
5
5
4
4

125
125
125
210
257
413

GAX-1
GAX-2
GAX-3
• GAX-4
• GAX-5
• GAX-6

X Style with Flange and Surface Cover
Cat.
No.
† GAFX-1
† GAFX-2
† GAFX-3

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

d"
f"
1"

1
1
1

4
4
4

135
135
135

Cover
Opening

Fits
Boxes

Std.
Pkg.

Wt. lbs.
per 100

3W"
3C"
5i"

d", f", 1"
1b"
1d", 2"

1
1
1

36
52
69

GAFX

Surface Style Cover
Cat.
No.

GAS

• GAS-123
• GAS-4
• GAS-56

Dome Style Cover (Class I, Group D only)
Cat.
No.
• GAD-123

Cover
Opening

Fits
Boxes

Inside
Height

Std.
Pkg.

Wt. lbs.
per 100

3W"

d", f", 1"

2e"

1

71

• Made to order items. Consult factory for lead time and minimum quantities.
† Suffix-OR: O-ring available for NEMA 4 rating. Consult factory for lead time and price.
GAD

A72

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 73

Aluminum Conduit Outlet Boxes
Explosion-Proof, Dust-Ignition-Proof

External Hubs with Installed Green Ground Screw,
Covers and Plugs

U Style with Canopy Cover
Cat.
No.

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

• GAJU-1
• GAJU-2
GAJU-3
• GAJU-5
GAJU-6

d"
f"
1"
1d"
2"

1
1
1

5
5
5
1
1

130
130
130
267
273

GAJU

Canopy Style Cover
Cat.
No.
• GAJ-123
• GAJ-4
• GAJ-56
GAJ

Cover
Opening

Fits
Boxes

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

3W"
3C"
5i"

d", f", 1"
1b"
1d", 2"

1
1
1

10
5
5

44
61
78

• Made to order items. Consult factory for lead time and minimum quantities.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A73

A
T&B ® Fittings

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 74

T&B ® Fittings

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

A
Aluminum Conduit Outlet Boxes
Explosion-Proof, Dust-Ignition-Proof
Dimensions and Cubic Inches (CI)

G

A

J B

D

F

C

K

E

H

EXUN & EXUNL
Hub
Size

A

B

C

D

E

F

G

H

J

K

CI

d"
f"
1"

3 O"
3 O"
3 O"

3a"
3a"
3j"

2y"
2y"
f"

2h"
2h"
2b"

4
4
4

3c"
3c"
3l"

4b"
4b"
4b"

1b"
1b"
1h"

1l"
1l"
1l"

å"
å"
å"

20.3
20.3
20.0

H

J

C

K

B
E

A

D

F

G

Dimensions of all styles
when GAJ cover is used

L

GAC, GAE, GAL, GALB, GAT, GAX
Cover
Opening

Hub
Size

A

B

C

D

E

F

G

H

J

K

L

CI

3W"
3W"
3W"
3C"
5i"
5i"

d"
f"
1"
1b"
1d"
2"

4"
4"
4"
4j"
5f"
5f"

2b"
2b"
2b"
3"
4b"
4b"

2n"
2n"
2n"
3W"
5h"
5h"

1c"
1c"
1e"
2h"
2g"
2g"

W"
W"
m"
1o"
1k"
1k"

W"
W"
B"
g"
g"
g"

5i"
5i"
5d"
5W"
6e"
6e"

5l"
5l"
5l"
–
–
–

4i"
4i"
4i"
4l""
6k"
6k"

3j"
3j"
3j"
3n"
5v"
5v"

l"
l"
l"
e"
m"
m"

18.8
18.8
18.8
28.0
69.3
69.3

A74

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 75

Aluminum Conduit Outlet Boxes
Explosion-Proof, Dust-Ignition-Proof
Dimensions and Cubic Inches (CI)
F
G
DIA

D

C B
A
M

E

i

H

L

GAFX
Cover
Opening

Hub
Size

A

B

C

D

E

F

G

H

L

M

CI

d"
f"
1"

4"
4"
4"

2b"
2b"
2b"

2n"
2n"
2n"

5l"
5l"
5l"

W"
W"
m"

4d"
4d"
4f"

b"
b"
j"

1c"
1c"
1e"

l"
l"
l"

5i"
5i"
5d"

20.0
20.0
19.0

3W"
3W"
3W"

Note: All GAF units supplied as X configuration with proper number of
explosion-proof close-up plugs to make C, T or L.

J

K

D
F

A

E

G

GAJU
Cover
Opening

Hub
Size

A

D

E

F

G

J

K

CI

3W"
3W"
3W"
3C"
5i"
5i"

d"
f"
1"
1b"
1d"
2"

4"
4"
4"
4j"
5f"
5f"

m"
m"
m"
2h"
1k"
1k"

1d"
1d"
1d"
1o"
2h"
2h"

O"
O"
O"
g"
1d"
1d"

5i"
5i"
5i"
5W"
6e"
6e"

4i"
4i"
4i"
4f"
6k"
6k"

4"
4"
4"
3n"
6i"
6i"

23.8
23.8
23.8
33.3
82.8
82.8

Note: All GA & GAF series boxes are supplied with GAS or GAJ style covers.
To order these boxes with GAD dome cover, consult factory.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A75

A
T&B ® Fittings

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 76

T&B ® Fittings

A
Aluminum Conduit Outlet Boxes
Explosion-Proof, Dust-Ignition-Proof

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations
®
®

Application
• Junction for branch conduits in hazardous locations.
• Accessible wiring chamber provides a convenient location to maintain
or change a system, pull conductors and make splices.
• Internal hub design ideal for installation where space is limited.
Features/Benefits
• Copper-free* aluminum provides increased corrosion resistance.
• Precision cast and machined surfaces permit safer wire pulling.
• Precision NPT threaded hubs allow trouble-free field installation for
rigid or IMC conduit.
• Die cast construction and industrial design combine to produce a
rugged protective enclosure for devices on industrial and OEM
applications.
• Clear UL, CSA and cubic content markings speed approval by
inspectors.

EXUN

Standard Materials
• Die cast aluminum alloy A360 with less than .004 copper content
(copper-free).
Standard Finish
• Aluminum lacquer finish

EXUNL

Compliances
• UL Listed
• CSA Certified
• Suitable for hazardous locations
• Federal Spec W-C-586

Copper-free
aluminum
Internal hub
design

Sample Specifications
• Outlet boxes for hazardous locations shall be die cast copper-free*
aluminum alloy A360 and suitable for use in Class I, Groups C, D,
Class II, Groups E, F, G and Class III areas. All conduit stops shall be
coined and free of rough edges. Outlet boxes for hazardous locations
shall be finished with aluminum lacquer. Outlet boxes shall be
Red•Dot® Catalog No. __________
*Less than .004 copper content.

Smooth
conduit
stops

A76

Precision
machined
threads

Internal
ground
boss and
screw

Die cast
lugs

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 77

Aluminum Conduit Outlet Boxes
Explosion-Proof, Dust-Ignition-Proof

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations

Internal Hubs with Installed Green Ground Screw

5 Hole Box
Cat.
No.

Hub
Size

Description

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

d"
f"
1"

5 outlets
with 3 close-up plugs
with 3 close-up plugs

1
1
1

5
5
5

140
140
140

Hub
Size

Description

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

1
1

5
5

140
140

EXUN-1
EXUN-2
EXUN-3

EXUN-1

4 Hole Box
Cat.
No.
EXUN-11
EXUN-22

d"
f"

4 outlets
with 2 close-up plugs

EXUN-11

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A77

A
T&B ® Fittings

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

412031.A01 FIT 3/12

3/20/03

3:04 PM

Page 78

T&B ® Fittings

A
Aluminum Conduit Outlet Boxes
Explosion-Proof, Dust-Ignition-Proof

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations
®

Application
• Junction for branch conduits in hazardous locations.
• Accessible wiring chamber provides a convenient location to maintain
or change a system, pull conductors and make splices.
®

Features/Benefits
• Copper-free* aluminum alloy provides increased corrosion resistance.
• Extra wide 3f" opening provides more hand space for easy access to
the wiring chamber.
• Precision cast and machined surfaces permit safer wire pulling.
• Large capacity 31 cu. in. chamber provides more wiring space.
• Precision NPT threaded hubs allow trouble-free field installation for
rigid or IMC conduit.
• Sand cast construction and industrial design combine to produce a
rugged protective enclosure for devices on industrial and OEM
applications.
• Clear UL, CSA and cubic content markings speed approval by
inspectors.
• Hub spacing allows use of EXFU and EXMU unions.

GASS

Standard Materials
• Box - Sand Cast aluminum alloy A356. 2-T6
• Cover - Die Cast aluminum alloy A360 with less than .004 copper
content (copper-free)
Standard Finish
• Aluminum lacquer finish
Compliances
• UL Listed
• CSA Certified
• NEC

Clean
cover
edges

Sample Specifications
• Enclosure for hazardous locations. The box shall be cast copper-free*
aluminum alloy A356.2-T6 . Suitable for use in hazardous locations:
Suitable for use in Class I, Groups C, D; Class II, Groups E, F, G; and
Class III areas. Enclosures shall be finished with aluminum lacquer.
Outlet boxes shall be Red•Dot® Catalog No. ______

Heavy wall
construction

*Less than .004 copper content.

Internal
ground
boss and
screw

A78

Precision
machined
threads

Copper-free
aluminum

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 79

Aluminum Conduit Outlet Boxes
Explosion-Proof, Dust-Ignition-Proof

Internal Hubs with Installed Green Ground Screw,
Cover and Plugs

Cat.
No.
GASS-1
GASS-2
GASS-3

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

d"
f"
1"

1
1
1

5
5
5

282
278
274

GASS

GASS
Cover
Opening
4”
4”
4”

Hub
Size

A

B

C

D

E

F

G

H

J

CI

d"
f"
1"

4e
4e
4e

2c
2c
2c

3c
3c
3c

2i
2i
2i

1i
1i
1i

d
d
d

f
f
f

4
4
4

2e
2e
2e

31
31
31

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A79

A
T&B ® Fittings

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 80

T&B ® Fittings

Aluminum Conduit Outlet Bodies
Explosion-Proof, Dust-Ignition-Proof
Precision
machined
threads and
surfaces

Heavy wall
construction

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

A

Application
• Junction for branch conduits.
• Accessible wiring chamber provides a convenient location to pull conductors
and make splices.

®

®

Deep
slotted
screws

Features/Benefits
• Copper-free* aluminum provides increased corrosion resistance.
• Precision cast and machined surfaces permit safer wire pulling.
• Precision NPT threaded hubs allow trouble-free field installation for rigid or
IMC conduit.
• Deep slotted cover screws for faster installation.
• Clear UL, CSA and cubic content markings speed approval by inspectors.
Standard Materials
• Die cast aluminum alloy A360 with less than .004 copper content
(copper-free).

Smooth
conduit
stops

Standard Finish
• Aluminum lacquer finish
Compliances
• UL Listed
• CSA Certified
• Suitable for hazardous locations
Sample Specifications
• Conduit fittings for hazardous locations shall be die cast copper free* aluminum alloy A360. Suitable for use in hazardous locations: Class I, Groups C,
D; Class II, Groups E, F, G and Class III. All conduit stops shall be coined and
free of rough edges. Conduit fittings shall be finished with aluminum lacquer.
Conduit fittings shall be Red•Dot® Catalog No. __________

Copper-free
aluminum

*Less than .004 copper content.

LB Style Conduit Body – Aluminum
Cat.
No.
EXLB-1
EXLB-2
EXLB-3

Hub
Size

Std.
Pkg.

Wt. lbs.
per 100

d"
f"
1"

5
5
5

76
94
132

EXLB

T Style Conduit Body – Aluminum
Cat.
No.
EXT-1
EXT-2
EXT-3

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

d"
f"
1"

5
5

25
25
5

92
115
172

EXT

A80

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 81

Conduit Outlet Bodies
Explosionproof, Dust-Ignitionproof

Application
OE series are installed in conduit systems within hazardous areas to:
• Protect conductors in threaded rigid conduit.
• Act as pulling and splice fittings.
• Interconnect lengths of conduit.
• Change direction of conduit.
• Provide access for maintenance and future system changes.
Features
OE conduit bodies have:
• Tapered threaded hubs for ground continuity.
• Smooth integral hub bushings to protect conductor insulation when pulling.
• Five different hub arrangements.
• Accurately machined body with blind tapped screw holes.
• Most compact design of all hazardous area outlet bodies.
• Sizes up to 1".
Standard Materials
• Bodies: Grade 60-45-10 Ductile Iron (Complies with ASTM standard A536)
Standard Finish
• Electrogalvanized and aluminum acrylic paint.
Size Ranges
• Hub – d" and f"
Certifications and Compliances
• NEC/CEC:Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III

OE Series – Iron Conduit Outlet Bodies

D

Cat.
No.

E

A

E

D

Hub
Size

A

B

C

D

E

F

OEC1-TB
OEC2-TB

d"
f"

4.06
4.35

1.62
1.88

1.90
2.19

0.69
0.69

0.88
0.88

0.63
0.76

OET1-TB
OET2-TB

d"
f"

4.06
4.35

1.62
1.88

1.90
2.19

0.69
0.69

0.88
0.88

0.63
0.76

OELL1-TB
OELL2-TB

d"
f"

4.06
4.35

1.62
1.88

1.90
2.19

0.69
0.69

0.88
0.88

0.63
0.76

OELR1-TB
OELR2-TB

d"
f"

4.06
4.35

1.62
1.88

1.90
2.19

0.69
0.69

0.88
0.88

0.63
0.76

OELB1-TB
OELB2-TB

d"
f"

4.06
4.35

1.62.
1.88

1.90
2.19

0.69
0.69

0.88
0.88

0.63
0.76

B

C
F
E

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A81

A
T&B ® Fittings

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

412031.A01 FIT 3/12

3/13/03

4:47 PM

Page 82

T&B ® Fittings

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

A
Conduit Outlet Elbows
Explosionproof, Dust-Ignitionproof

Conduit Bodies and Capped Elbows
Application
LBY/GYF elbows are installed in conduit systems within hazardous areas to:
• Make 90° bends in conduit systems where space is limited.
• Act as pull outlets.
• Provide access to conductors for maintenance and future system changes.
Features
• Maximum volume for bends within a compact overall size.
• Screw on cover for ease of installation and removal.
• Cover opening on an angle, permitting conductors to be pulled straight
through either hub.
• Tapered threaded hubs and integral bushing for rigid threaded conduit.
LBY –
Class I, Division 1 & 2, Groups C,D
Class II, Division 1, Groups F,G
Class III
Class I, Division 1 & 2, Groups C,D
Class II, Division 1, Groups F,G
Class III

LBY

B

®

Capped Iron Elbow – Female to Female
Cat.
No.

A

LBY15-TB
LBY25-TB
LBY35-TB
LBY45-TB
LBY55-TB
LBY65-TB

Throat Dim.
Max

Hub
Size

A

B

Min

d
f
1
1b
1d
2

2l
2m
3p
3f
4b
5d

2
2b
2d
2n
3c
4

0.570
0.755
0.955
1.260
1.470
1.880

0.610
0.810
1.035
1.360
1.590
2.047

LBY Elbows have:
• Maximum volume for bends within a compact overall size.
• Screw on cover for ease of installation and removal.
• Cover opening on an angle, permitting conductors to
be pulled straight through either hub.
• Tapered threaded hubs and integral bushing for
rigid threaded conduit.

®

Capped Aluminum Elbow – Female to Female
Cat.
No.
GYF-1
GYF-2
GYF-3
• GYF-4
GYF-5

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

d"
f"
1"
1b"
1d"

10
5
5
2
2

50
25
25
10
10

23
40
60
80
95

• Made to order items. Consult factory for lead time and minimum quantities.
GYF

A82

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:48 PM

Page 83

Application
• RE and REC reducers are used in threaded heavy wall
conduit systems.
• RE reduces conduit hubs to a smaller size.
• REC connects two different sizes of conduit together or is
used to replace a coupling and reducer in an installation.
• PLG plugs are used for closing threaded conduit hubs.

• Funnel Reducers: Iron
• Recessed Plugs: Gray Iron
• red•dot® Recessed Plugs: Copper-free Aluminum

Materials
• Machined Reducers: Steel
• Cast Reducers: Gray Iron

Listing Certifications
• UL: 886
• CSA: C22.2 No.30
• NEC/CEC: CI.I, Div. 1 & 2, Groups A, B, C, D
CI.II, Div. 1, Groups E, F, G
CI.III
For hazardous and non-hazardous locations

Reducing Bushings

Recessed Plugs

Cat.
No.

Cat.
No.

A Male
(NPT)

B Female
(NPT)

RE21-TB
RE31-TB
RE32-TB
RE41-TB
RE42-TB
RE43-TB
RE51-TB
RE52-TB
RE53-TB
RE54-TB

f
1
1
1b
1b
1b
1d
1d
1d
1d

d
d
f
d
f
1
d
f
1
1b

RE61-TB
RE62-TB
RE63-TB
RE64-TB
RE65-TB
RE73-TB
RE74-TB
RE75-TB
RE76-TB

2
2
2
2
2
2d
2d
2d
2d

d
f
1
1b
1d
1
1b
1d
2

RE83-TB
RE84-TB
RE85-TB
RE86-TB
RE87-TB
RE96-TB
RE97-TB

3
3
3
3
3
3d
3d

1
1b
1d
2
2d
2
2d

RE98-TB
RE106-TB
RE107-TB
RE108-TB

4
4
4
4

3
2
2d
3

REC Series Reducers
B
(NPT)

C

Funnel Shaped Reducers for
Hazardous and Non-Hazardous
Locations

C

A

A
(NPT)

B

REC21-TB
REC31-TB
REC32-TB

f
1
1

d - 14
d - 14
f - 14

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

®
®

Standard Finishes
• Cast zinc-plated with aluminum acrylic paint
• Machine zinc-plated with clear chromate finish

Features
• All Hubs have NPT threads with a minimum of five full threads
and integral bushing for preventing damage to wires.

Cat.
No.

A

1g
2
2

www.tnb.com

Threads
(NPT)

With Flush Head for Hazardous and
Non-Hazardous Locations
PLG1-TB
PLG2-TB
PLG3-TB
PLG4-TB
PLG5-TB
PLG6-TB
PLG7-TB
PLG8-TB
PLG9-TB
PLG10-TB

d
f
1
1b
1d
2
2d
3
3d
4

Aluminum Recessed Plugs
Cat.
No.

Hub
Size

With Flush Head for Hazardous and
Non-Hazardous Locations
XPLG-1†
XPLG-2†
XPLG-3†
XPLG-4*
XPLG-5*
XPLG-6*
XPLG-7*
XPLG-8*
XPLG-9*
XPLG-10*

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

Made to order items. Consult factory for lead time and
minimum quantities.
† Not U.L. Listed
* U.L. Listed E 34438

A83

T&B ® Fittings

RE, PLG, REC Reducers, Plugs and Adapters
Explosionproof, Dust-Ignitionproof

CI.I, Div. 1 & 2, Groups A, B, C, D Explosionproof
Dust-Ignitionproof
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2

412031.A01 FIT 3/12

3/13/03

4:48 PM

Page 84

T&B ® Fittings

A
Three-Piece Couplings
Explosionproof, Dust-Ignitionproof

CI.I, Div. 1 & 2, Groups A,B,C,D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2

Explosionproof
Dust-Ignitionproof
®
®

Application
UNY and UNF unions are installed in threaded thickwall conduit systems:
• UNY – to connect conduit to a conduit fitting, junction box, or device enclosure.
• UNF – to connect conduit to conduit, or to provide a means for future modification of the conduit system.
Standard Finishes
• Steel – electrogalvanized with chromate treatment.
• Iron alloy, malleable iron – electrogalvanized and aluminum
acrylic paint

UNY

UNF

Certifications and Compliances*
• NEC/CEC
Class I, Division 1 & 2, Groups A,B,C,D
Class II, Division 1, Groups E,F,G
Class III
UNF, UNY d" – 1"
• UL – Conduit unions for use in Cat. Nos. UNF/UNY
followed by 105, 205, or 305; for use in:
Class I, Division 1 & 2, Groups A,B,C,D
Class II, Division 1, Groups E,F,G
Class III
UNF,UNY d", f", 1"
• CSA – Conduit unions for use in Cat. Nos. UNF/UNY
followed by 105, 205, 305, 405 or 505; for use in:
Class I, Division 1 & 2, Groups B,C,D
Class II, Division 1, Groups E,F,G
Class III
UNF,UNY d", f", 1", 1b", 1d"
• UL – Conduit unions for use in Cat. Nos. UNF/UNY
followed by 405 or 505; for use in:
Class I, Division 1 & 2, Groups B,C,D
Class II, Division 1, Groups E,F,G
Class III
UNF,UNY 1b", 1d"
• UL & CSA – Conduit unions for use in Cat. Nos. UNF/UNY, EL Series
followed by 605, 905, or 1005; for use in:
Class I, Division 1 & 2, Groups C,D
Class II, Division 1, Groups E,F,G
Class III
UNF,UNY 2", 2d", 3", 3d", 4"

A84

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:48 PM

Page 85

Three-Piece Couplings
Explosionproof, Dust-Ignitionproof

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

A
®

®

UNY Male Unions
Cat.
No.

TR Size

Overall
Length/Inches

Overall
Dia./Inches

2ç
2k
2f
3h
3e
3d
4m
5X
5d
5e

1d
1m
2
2f
3h
3m
4j
5h
5W
6i

Overall
Length/Inches

Overall
Dia./Inches

1g
2a
2q
2b
2f
2d
3d
4
4q
4b

1d
1m
2
2f
3h
3m
4j
5h
5W
6i

For Hazardous and Non-Hazardous Locations

UNY

UNY105-TB
UNY205-TB
UNY305-TB
UNY405-TB
UNY505-TB
UNY605-TB
UNY705-TB
UNY805-TB
UNY905-TB
UNY1005-TB

d
f
1
1b
1d
2
2d
3
3d
4

LENGTH

LENGTH

MAX. DIA.

MAX. DIA.

UNF Female Unions
Cat.
No.

TR Size

For Hazardous and Non-Hazardous Locations

UNF

UNF105-TB
UNF205-TB
UNF305-TB
UNF405-TB
UNF505-TB
UNF605-TB
UNF705-TB
UNF805-TB
UNF905-TB
UNF1005-TB

d
f
1
1f
1d
2
2d
3
3d
4

LENGTH

LENGTH

MAX. DIA.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

MAX. DIA.

A85

T&B ® Fittings

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

412031.A01 FIT 3/12

3/13/03

4:48 PM

Page 86

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

T&B ® Fittings

A
Aluminum Three-Piece Couplings
Explosion-Proof, Dust-Ignition-Proof

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations

®

®

Application
• Unions are used as connecting elements between enclosures, fittings or boxes which permit future changes to the system in both
hazardous and non-hazardous areas.
Features/Benefits
• Copper-free* aluminum provides increased corrosion resistance.
• Precision cast and machined surfaces permit safer wire pulling.
• Precision NPT threaded hubs allow trouble-free field installation for
rigid or IMC conduit.
• Clear UL, CSA and cubic content markings speed approval by
inspectors.
• Unique concentric ring design insures critical flame path control.

EXFU

Standard Materials
• Die cast aluminum alloy A360 with less than .004 copper content
(copper-free).
• EXMU nipples are galvanized steel.
Standard Finish
• Aluminum lacquer finish
Compliances
• UL Listed
• CSA Certified
• Suitable for hazardous locations
• Federal Spec W-C-586

EXMU

Precision
machined
threads
Unique concentric ring
design

Smooth
conduit
stops

Sample Specifications
• Conduit unions for hazardous locations shall be die cast copperfree* aluminum alloy A360. Suitable for use in hazardous locations: Class I, Groups C, D; Class II, Groups E, F, G and Class III.
All conduit stops shall be coined and free of rough edges. Conduit
unions shall be finished with aluminum lacquer. Conduit unions
shall be Red•Dot® Catalog No. __________
*Less than .004 copper content.

Copper-free
aluminum

A86

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:48 PM

Page 87

Male and Female Unions

®

Female to Female
Cat.
No.

EXFU

EXFU-1
EXFU-2
EXFU-3
EXFU-4
EXFU-5
• EXFU-6
• EXFU-7
• EXFU-8
• EXFU-9
• EXFU-10

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

d’
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

5
5
5
5
5
2
2
1
1

25
25
25
25
25
10
10
5
5
1

24
33
42
53
68
130
270
310
340
374

®

Male to Female
Cat.
No.

EXMU

EXMU-1
EXMU-2
EXMU-3
• EXMU-4
• EXMU-5
• EXMU-6
• EXMU-7
• EXMU-8
• EXMU-9
• EXMU-10

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

5
5
5
5
5
2
2
1
1

25
25
25
25
25
10
10
5
5
1

24
35
45
64
84
155
300
340
400
410

• Made to order items. Consult factory for lead time and minimum quantities.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A87

A
T&B ® Fittings

Aluminum Three-Piece Couplings
Explosion-Proof, Dust-Ignition-Proof

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

412031.A01 FIT 3/12

3/13/03

4:48 PM

Page 88

T&B ® Fittings

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

A
Elbows
Explosionproof, Dust-Ignitionproof

45° Female Elbow
in ounces per hub.
Cat.
No.

A

EL1-TB
EL2-TB
EL3-TB
EL4-TB
EL5-TB
EL6-TB
EL7-TB
EL8-TB
EL9-TB
EL10-TB

A

Hub
Size

A

d
f
1
1b
1d
2
2d
3
3d
4

1.268
1.402
1.643
1.846
2.14
2.326
2.848
3.149
3.533
3.975

Hub
Size

A

1d
f
1
1b
1d
2
2d

1.75
1.965
2.15
2.425
4.047
5.02
6.375

90° Female Elbow
in ounces per hub.
A

Cat.
No.
EL19-TB
EL29-TB
EL39-TB
EL49-TB
EL59-TB
EL69-TB
EL79-TB

A

A

90° Male Elbow
in ounces per hub.
Cat.
No.

A

EL195-TB
EL295-TB
EL395-TB

Hub
Size

A

d
f
1

1.422
1.625
1.875

B

90° Male & Female Elbow
in ounces per hub.
Cat.
No.
A

A88

EL196-TB
EL296-TB
EL396-TB
EL496-TB

Hub
Size

A

B

d
f
1
1b

1.695
1.933
2.085
2.46

1.675
1.813
2.17
2.281

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A01 FIT 3/12

3/13/03

4:48 PM

Page 89

Flexible Couplings
Explosionproof, Dust-Ignitionproof

NEMA7 ABCD
9EFG
12

Male to Male
Cat.
No.

EXFC Series

Conduit
Size

Flex
Length

Std.
Pkg.

Wt. lbs
per 100

• EXFC-104
EXFC-106
EXFC-108
EXFC-110
EXFC-112
EXFC-115
EXFC-118
• EXFC-121
EXFC-124
EXFC-127
• EXFC-130
• EXFC-133
EXFC-136

d"
d"
d"
d"
d"
d"
d"
d"
d"
d"
d"
d"
d"

4”
6”
8”
10”
12”
15”
18”
21”
24”
27”
30”
33”
36”

1
1
1
1
1
1
1
1
1
1
1
1
1

175
200
225
238
250
262
300
312
325
337
350
375
400

• EXFC-204
EXFC-206
EXFC-208
EXFC-210
EXFC-212
EXFC-215
EXFC-218
• EXFC-221
EXFC-224
• EXFC-227
• EXFC-230
• EXFC-233
EXFC-236

f"
f"
f"
f"
f"
f"
f"
f"
f"
f"
f"
f"
f"

4”
6”
8”
10”
12”
15”
18”
21”
24”
27”
30”
33”
36”

1
1
1
1
1
1
1
1
1
1
1
1
1

200
225
237
250
262
300
312
325
337
350
375
400
450

EXFC-306
EXFC-308
EXFC-310
• EXFC-312
• EXFC-315
• EXFC-318
EXFC-321
• EXFC-324
• EXFC-327
• EXFC-330
• EXFC-333
EXFC-336

1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"

6”
8”
10”
12”
15”
18”
21”
24”
27”
30”
33”
36”

1
1
1
1
1
1
1
1
1
1
1
1

225
250
262
275
300
325
350
375
412
450
487
525

• EXFC-412
• EXFC-415
• EXFC-418
• EXFC-421
• EXFC-424
• EXFC-427
• EXFC-430
• EXFC-433
• EXFC-436

1b"
1b"
1b"
1b"
1b"
1b"
1b"
1b"
1b"

12”
15”
18”
21”
24”
27”
30”
33”
36”

1
1
1
1
1
1
1
1
1

650
700
750
825
875
950
1025
1075
1125

• EXFC-512
• EXFC-515
• EXFC-518
• EXFC-521
• EXFC-524
• EXFC-527
• EXFC-530
• EXFC-533
• EXFC-536

1d"
1d"
1d"
1d"
1d"
1d"
1d"
1d"
1d"

12”
15”
18”
21”
24”
27”
30”
33”
36”

1
1
1
1
1
1
1
1
1

825
900
1000
1100
1200
1300
1400
1500
1600

• Made to order items. Consult factory for lead time and minimum quantities.
Unions are not supplied with flexible couplings as shown in photo.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A89

A
T&B ® Fittings

Cl. I, Div. 1 & 2, Groups A, B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. III, Div. 1 & 2

412031.A01 FIT 3/12

3/13/03

4:48 PM

Page 90

T&B ® Fittings

A
Sealing Fittings
Explosionproof, Dust-Ignitionproof
Application
EYD drain and inspection sealing fittings:
• Restrict the passage of gases, vapors or flames from one portion of
the electrical installation to another at atmospheric pressure and
normal ambient temperatures.
• Limit explosions to the sealed-off enclosure.
• Prevent precompression or “pressure piling” in conduit systems.
Drain sealing fittings are installed in vertical conduit runs and at low
points in conduit systems to prevent accumulation of condensate
above seal.
Features:
EYD drain sealing fittings include:
• Drain to provide continuous, automatic drainage of condensate.
• Large openings with threaded closures to provide easy access to
conduit hubs for making dams.
• Integral bushings to protect conductor insulation from damage.
• Tapered-tapped hubs to ensure ground continuity.
Standard Materials
• Bodies, and inspection or drain covers – Gray iron alloy and/or
ductile iron.
• Closure for drain – copper-free aluminum or ductile iron.
• Small closure plug – Gray iron alloy and/or steel.
• Drain – stainless steel.
• Removable nipples – steel.
Standard Finish
• Gray iron alloy and ductile iron – electrogalvanized and aluminum
acrylic paint.
• Copper-free aluminum – natural.
• Stainless steel – natural
• Steel – electrogalvanized.
Options
• Copper-free aluminum bodies, nipples and enclosures –
see listings
Size Ranges
• EYD – d" – 4"
Certifications and Compliances*
NEC/CEC:
• EYD11 – 31-TB
Class I, Division 1 & 2, Groups A,B,C,D.
Class II, Division 1, Groups E,F,G.
Class III.
• EYD41 – 101-TB
Class I, Division 1 & 2, Groups C,D.
Class II, Division 1, Groups E,F,G.
Class II, Division 2, Groups F,G.
Class III.
• UL Standard: 886
• CSA Standard: C22.2
• Seals are approved to be used with Crouse-Hinds® Sealing
Compound and Fiber.
Crouse-Hinds® is a trademark of Cooper Industries, Inc.

A90

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:55 PM

Page 91

Sealing Fittings
Explosionproof, Dust-Ignitionproof

NEMA7
9EFG
12

A
®

®

EYD Drain Seals
Cat.
No.

Size

A

B

Turning
Radius

EYD11-TB
EYD21-TB
EYD31-TB
EYD41-TB
EYD51-TB
EYD61-TB
EYD71-TB
EYD81-TB
EYD91-TB
EYD101-TB

d
f
1
1b
1d
2
2d
3
3d
4

3.81
4.08
4.85
5.00
5.44
6.25
7.50
8.50
9.19
9.75

1.50
1.75
2.19
2.25
2.44
3.00
3.50
4.25
4.75
5.25

1.75
1.98
2.19
1.80
2.00
2.32
2.69
3.15
3.38
3.64

T&B ® Fittings

Cl. I, Div. 1 & 2, Groups A, B, C, D*
Cl. II, Div. 1, Groups E, F, G
Cl. III, Div. 1 & 2

B

Turning
Radius

Turning
Radius

B

A

A
EYD d" - 1"

EYD d" - 1"

EYD 1b" - 4"

Drains/Breathers for Hazardous Locations
Cat.
No.
ECD15
ECD384
ECD284

Size

Dim. “D”

d
c
b

.975
.407
.327

Application
The Thomas & Betts Universal drain/breather fittings can be used as drains
or breathers depending on the installation.
• To use as a drain, the product must be installed in the bottom of the enclosure or the lowest point where an NPT threaded opening exists. It can also
be used in a seal fitting or a “T” conduit body. These must be in a lower section of the conduit system. This will allow moisture inside the conduit system
to drain out.
• To use as a breather, installation should be done at the top of an enclosure
or in upper sections of conduit systems. This will permit air exchange and
keep moisture accumulation inside the conduit system to a minimum,
Thomas & Betts recommends the use of at least 2 devices (one drain and
one breather) for maximum efficency.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A91

412031.A02 FIT 3/5

3/13/03

4:55 PM

Page 92

Cl. I, Div. 1 & 2, Groups A, B, C, D*
Cl. II, Div. 1, Groups E, F, G
Cl. III, Div. 1 & 2

T&B ® Fittings

A
Sealing Fittings
Explosionproof, Dust-Ignitionproof

Explosionproof
Dust-Ignitionproof

®

EYS Sealing Fittings

®

Application
EYS sealing fittings can be installed in either vertical or horizontal applications.
• Seals sections of conduit runs from passage of vapors, flame, or gases.
• Seals off sections of conduit system during explosion.
• Limits precompression or pressure piling in conduit system.
Features
• All hubs have a minimum of five full threads, integral bushings to protect conductor insulation from damage, and large access openings for easier packing
of sealing medium.
• Seals are approved to be used with Crouse-Hinds® Sealing Compound
and Fiber.
Size Range
• d" NPT to 4" NPT
Materials
• Bodies: Ductile Iron
• Plugs: Gray Iron
• Nipples: Steel, supplied with EYS fittings
Finish
• Bodies: Zinc-plated with aluminum acrylic paint
• Plugs: Zinc-plated with aluminum acrylic paint
• Nipples: Zinc-plated
Listing Certifications and Compliances
• UL886
• CSA: C22.2 No. 30
* EYS seals are approved to be used with Crouse-Hinds® Chico®A compound
and Chico®X fiber.
CHCHICO – X6 (8 oz. Chico X Fiber)
CHCHICO – A3 (1 lb. can Sealing Compound
CHCHICO – A4 (1 lb. can/1 oz. Chico X Fiber)

B

A

EYS11-TB – EYS101-TB

NEC/CEC:
EYS1-3TB*
Cl. I, Div. 1 & 2, Groups A, B, C, D
EYS4-5TB*
Cl. I, Div. 1 & 2, Groups C, D

EYS11-31TB*
Cl. I, Div. 1 & 2, Groups A, B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. III
EYS41-101TB*
Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. III

EYS Sealing Fittings

A

C

B

EYS1-TB – EYS5-TB

Dimensions (Inches)

Cat.
No.

Hub
Size

A

B

C

Turning
Radius

EYS1-TB*
EYS2-TB*
EYS3-TB*
EYS4-TB*
EYS5-TB*
EYS11-TB
EYS21-TB
EYS31-TB
EYS41-TB
EYS51-TB
EYS61-TB
EYS71-TB
EYS81-TB
EYS91-TB
EYS101-TB

d
f
1
1b
1d
d
f
1
1b
1d
2
2d
3
3d
4

3.31
3.65
4.25
5.00
5.69
3e
3y
4b
5
5k
6b
7d
8d
9i
9f

1.25
1.50
1.75
2.25
2.45
1b
1d
1f
2b
2k
3
3d
4b
4f
5b

1.50
1.75
2.19
2.45
3.00
–
–
–
–
–
–
–
–
–
–

1.66
1.96
2.40
3.11
3.62
1p
1b
1X
1m
2
2j
2L
3q
3c
3w

Crouse-Hinds® and Chico® are trademarks of Cooper Industries, Inc.
*Vertical Only

A92

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:55 PM

Page 93

Aluminum Sealing Fittings
Explosion-Proof, Dust-Ignition-Proof

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations
®
®

Application
• Limits flames and/or explosions to area within electrical system
where they originate.
• Limits pressure piling.
• Required by NEC for conduit systems in hazardous locations 18"
from an enclosure housing a heat producing or arcing device; on
2” and larger system which enters an enclosure containing splices;
wherever conduit leaves a Class I, Division I area and enters a nonhazardous area.

EYVF
EVHF

Features/Benefits
• Copper-free* aluminum provides increased corrosion resistance.
• Precision cast and machined surfaces permit safer wire pulling.
• Precision NPT threaded hubs allow trouble-free field installation for
rigid or IMC conduit.
• Large opening provides maximum working room for creating dam
and seal pouring to speed up installation.
• Compact design permits close construction of parallel conduit runs.

EVHF

Precision
machined
threads

Standard Materials
• Sealing Fittings: Die cast aluminum alloy A360 with less than .004
copper content (copper-free).
• Sealing Cement
• Fiber: Flame retardant Kaowool Type A fiber.
Standard Finish
• Aluminum lacquer finish
Compliances
• UL Listed
• CSA Certified
• Suitable for hazardous locations
• Federal Spec W-C-586

Large aperture for
easy installation

Smooth
conduit
stops

Sample Specifications
• Sealing fittings for hazardous locations shall be die cast copperfree* aluminum alloy A360. Suitable for use in hazardous locations:
Class I, Groups C, D; Class II, Groups E, F, G and Class III. All conduit stops shall be coined and free of rough edges. Sealing fittings
for hazardous locations shall be finished with aluminum lacquer.
Sealing fittings shall be Red•Dot® Catalog No. __________
*Less than .004 copper content.

Copper-free
aluminum

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A93

A
T&B ® Fittings

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

412031.A02 FIT 3/5

3/13/03

4:55 PM

Page 94

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

T&B ® Fittings

A
Aluminum Sealing Fittings
Explosion-Proof, Dust-Ignition-Proof

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations

Vertical and Horizontal

Vertical
Cat.
No.
† EYVF-1
† EYVF-2
† EYVF-3
EYVF-11
EYVF-22
EYVF-33

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

d"
f"
1"
d"
f"
1"

5
5
5
10
10
4

25
25
25
50
50
20

50
54
100
35
40
60

EYVF

Vertical/Horizontal
Cat.
No.

Hub
Size

Unit
Qty.

Std.
Pkg.

Wt. lbs.
per 100

EVHF-1
EVHF-2
EVHF-3
EVHF-4
EVHF-5
EVHF-6
• EVHF-7
• EVHF-8
• EVHF-9
• EVHF-10

d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

10
5
5
4
1
1
1
1
1
1

50
25
25
20
5
1
1
1
1
1

41
50
60
70
60
125
150
250
300
400

• Made to order items. Consult factory for lead time and minimum quantities.
† Packaged with an adequate amount of sealing compound and plugs installed.
EVHF-1 through -3

A94

EVHF-4 through -10

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:55 PM

Page 95

Aluminum Sealing Fittings
Explosion-Proof, Dust-Ignition-Proof

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations

Preparation
Applications
Red•Dot® sealing cement is used for making seals in sealing fittings.
The insulation in the conductors sealed in the cement may be approved
thermoplastic or rubber, with or without lead covering. The sealing cement
should not be used for insulating.
Characteristics
Red•Dot® sealing cement is not affected by gasoline, alcohol, acetone,
ether, naptha, petroleum, benzol or lacquer solvent.

Sealing Cement

Packing Fiber

Preparation
(1) Use a clean mixing vessel for each batch.
(2) Thoroughly mix powder before adding water.
(3) Do not use if temperature is below 40°F.
(4) Mix 1 part water to 2 parts cement.
(5) Allow cement to set for 72 hours before use.
Standard Dams
(1) Push the conductors away from the filling opening and force them apart
so that they do not touch each other or the walls of the fitting or conduit
along their length. If the conductors do touch, the sealing cement will
not form a closed path between them.
(2) Force the packing fiber between each conductor and the inside walls.
Be sure that the dam is strong enough and tight enough to prevent the
considerable weight of the fluid sealing cement from seeping out.
Pouring
(1) Pour the mixed cement into the fitting slowly so as not to trap air in the
seal.
(2) Replace the close-up plugs to insure that they engage not less than 5
full threads.

Vertical Installation
for EYVF or EVHF Fittings

Sealing
Cement

Packing Fiber
Horizontal EVF Installation

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A95

A
T&B ® Fittings

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

412031.A02 FIT 3/5

3/13/03

4:55 PM

Page 96

T&B ® Fittings

Explosionproof
Dust Ignition-proof
Raintight
Wet Locations

CI.I, Div. 1 & 2, Groups C, D
CI.II, Div. 1, Groups E, F, G
CI.III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG

A
Sealing Fittings
Explosion-Proof, Dust-Ignition-Proof

Sealing Cement and Fiber for Red•Dot ® Sealing Fittings

Sealing Cement • Can be used on Red•Dot

®

Cat.
No.
EXSC-2
EXSC-8
EXSC-16

Quantity

Volume
Cubic Inches

Std.
Pkg.

Wt. lbs
per 100

3.2 oz.
13 oz.
1 lb., 10 oz.

2.75”
11.50”
23.00”

25
15
10

20
81
163

Packing Fiber • Can be used on Red•Dot

®

EXSC

Cat.
No.

EYV, EVH series fittings only.

Volume
Cubic Inches

Quantity

EXPF-16

EYV, EVH series fittings only.

1 lb.

Std.
Pkg.

Wt. lbs
per 100

1

112

Approximate amount of cement and fiber required
in ounces per hub.
Cat.
No.

EXPF

A96

EYVF-11
EYVF-22
EYVF-33
EVHF-1
EVHF-2
EVHF-3
EVHF-4
EVHF-5
EVHF-6
EVHF-7
EVHF-8
EVHF-9
EVHF-10

Hub
Size

Cement
Quantity

Fiber
Quantity

d"
f"
1"
d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

2 oz.
3 oz.
4 oz.
2 oz.
2 oz.
4 oz.
4 oz.
6 oz.
12 oz.
15 oz.
40 oz.
45 oz.
50 oz.

o oz.
h oz.
a oz.
o oz.
o oz.
b oz.
b oz.
d oz.
1 oz.
1d oz.
2 oz.
3 oz.
4 oz.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:55 PM

Page 97

A
™

The Copper Colloidal Surface Treatment That Protects,
Lubricates and Enhances Conductivity Between All Electrical
Connections

Kopr-Shield™ by Thomas & Betts meets the
requirements of Section 300.6(A) in the
2002 NEC Code for Protection Against
Corrosion.
“Where corrosion protection is
necessary and the conduit is
threaded in the field, the threads
shall be coated with an
approved electrically conductive,
corrosion-resistant compound.”

Good connections are one of the most important aspects of electrical work.
Mechanics know how much down-time is caused when fluids or oils leak into the
raceway system or looking for a weak link in a ground system caused by a high
resistance connection. Mechanics also know how much time is spent keeping contacts, switches, lugs and other connectors clean or replacing parts because of
“green scourge” build-up. Thomas & Betts has the solution to improve connections
made in thousands of electrical and raceway installations made each day by electricians everywhere.
Kopr-Shield™ compound is a unique homogenized blend of pure, polished colloidal
copper, rust and corrosion inhibitors that simultaneously protects, lubricates and
enhances the conductivity of the mating surfaces to which it is applied. Extremely
adhesive, Kopr-Shield™ compound flows smoothly into uneven contours and voids,
making application easy, protection and lubrication complete and positive. A stable compound, it will not settle-out, thin, thicken, harden, or dry out under the most
severe environmental conditions.
Kopr-Shield™ Compound has excellent temperature characteristics – brushed on at
–50F to 250F (other compounds either turn solid or run like water at these
extremes). Even at 1800F, Kopr-Shield™ remains intact for short terms.
Kopr-Shield™ Compound may be used to advantage in all electrical installations.
When the environment is hostile to good electrical and mechanical connections,
Kopr-Shield™ Compound is a must!
Use Kopr-Shield™ Compound for Battery Lugs and Cables.
• Prevention of “Green Scourge” corrosion.
• Reduction of resistance.
• Ease of terminal installation and removal.
Use Kopr-Shield™ Compound for Raceways.
• Lubrication – Ease of assembly and disassembly.
• Grounding Continuity Improved – Exceeds code requirements.
Use Kopr-Shield™ Compound for Fuse Clips.
• Even Heat Distribution – Elimination of hot spots.
• Oxidation Prevention – Prevents carbon path formation.
• Lubrication – Easy installation and removal of fuses.
Use Kopr-Shield™ Compound for Wiping Contacts, Drum Switches and Slip
Rings.
• Prevention of galling, burning, pitting and discoloration.
• Suppression of arching and dissipation of coronas.
• Lubrication for ease of operation.

Kopr-Shield™
Cat. No.
201-31879
201-31879-1
CP8-TB
CP16
CP128

Description
1d oz. Container with brush
4 oz. Container with brush
8 oz. Container with brush
16 oz. Container with brush
1 Gallon Can

Std. Pkg.

Wt. Lbs./C

96
24
12
12
4

11.46
38.54
64.58
120.83
952.00

Kopr-Shield™ is a product of Jet Lube, Inc.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A97

T&B ® Fittings

Kopr-Shield Compound

412031.A02 FIT 3/5

3/13/03

4:55 PM

Page 98

T&B ® Fittings

A
Metal Clad Cable Termination Fittings
Metal Clad Cable Teck Cable Aluminum Sheathed Cable
Metal Clad Cable
(Type MC)
Ref. NEC Article 334*
“Metal Clad Cable Type MC is a factory
assembly of one or more conductors,
each individually insulated and enclosed
in a metallic sheath of interlocking tape,
or a smooth or corrugated tube.”
Metal Clad Cable Type MC is rated
for use up to 5,000 volts. The National
Electrical Code permits use of metallic
sheath as an equipment grounding
conductor.
Metal Clad Cables are available with
a variety of phase conductor insulations
such as crosslinked polyethylene, and
silicone rubber ethylene propylene,
depending on rated temperature of conductors and working potential. Metallic
sheath can be of galvanized steel, aluminum, copper or bronze. A special
outer covering such as PVC or
Neoprene over metallic sheath is usually provided for environmental protection.
Metal clad cable is not permitted in
locations where it could be subject to
physical damage. Metal clad cable
can be used exposed, concealed, in
cable tray, in any approved raceway,
and with minor exceptions in hazardous locations. Type MC cable can
also be used for services, feeders,
branch circuits, power, lighting, control
and signal circuits.
Use of metal clad cable is permitted
in wet locations, or where exposed to
destructive corrosive conditions or can

A98

be directly buried in earth, concrete or
exposed to cinder fills, strong chlorides, caustic alkalis, vapors, chlorine
or hydrochloric acids provided the
construction of cable, the conductors
within the metallic sheath, the metallic
sheath and protective cover over
metallic sheath comply with requirements enumerated in Sec. 334-3 of the
National Electrical Code.
Bend radius restrictions are dependent on the size of the cable and the
type of sheath, i.e. smooth, interlocked
armor, corrugated sheath or shielded
conductors and varies from 7 times to
15 times cable external diameter.
NEC Article 334 requires that
approved fittings be used for termination. Where single-conductor cables
carrying alternating current enter a ferrous metal box or enclosure, procedures described in NEC Section 30020 must be followed to reduce effects
of heating due to induced currents.
These procedures include recommended arrangements of conductors,
cutting of slots in metal between individual conductor holes, passing of
conductors through insulating walls, or
use of non-magnetic aluminum
sheathed cable and aluminum terminating fittings.
Portions of this section reprinted by
permission from NFPA 70-1999,
National Electrical Code®,
Copyright © 1977, National Fire
Protection Association, Boston, MA.

Please refer to the following for further
details and complete information:
1. NEC Article 334…Metal Clad
Cable (Type MC)
2. U.L. 4, ANSI C33.9…Safety
Standards for Type MC Metal Clad
Cable
3. U.L. 514B, Safety Standards for
Outlet Boxes & Fittings
4. W-F-406…Federal Specification.
Fittings for Cable, Power
Electrical & Conduit Metal, Flexible
5. NEMA FM-1…Standards
Publication. Fittings and Supports
for Conduit and Cable Assemblies
• In the 1978 National Electric Code,
Aluminum Sheathed Cable is classified as type MC metal clad cable
(NEC Article 334); however in 1975
National Electric Code Aluminum
Sheathed Cable was classified as
type ALS cable and covered under a
separate article (NEC Article 331)

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:55 PM

Page 99

A

Metal Clad Cable Teck Cable Aluminum Sheathed Cable – continued
Teck Cables
Teck cable derived its name from one
of its first users, the Teck-Hughes Gold
Mines in Kirkland Lake, Ontario. Teck
90 is CSA Type designation. Trade designation of this cable is Armored Cable.
Teck cables up to 5,000 volt working
potential are manufactured in accordance with CSA Standard C22.2 No.
131 and are provided with a bare
ground conductor and an optional
outer jacket. Depending on phase conductor insulation the cables are designated as Teck 90 (X-LINK) when insulation is cross-linked polyethylene and
Teck 90 (EP) when insulation is ethylene propylene. Both cables are rated
for 90°C service (dry location) and
75°C (wet locations). When Teck cable
is suitable for installation down to
minus 40°F the cables are marked
Teck 90 (X-LINK) minus 40 or Teck 90
(EP) minus 40.
Over 5,000 volts working potential
Teck cables are manufactured in accordance with IPCEA standards and are
certified by CSA. Cables are provided
with or without ground wire as required.
Teck cables with outer jacket may
be used for exposed or concealed

wiring in wet or dry locations,
indoors/outdoors and in corrosive environments. Teck cables are suitable for
use in ventilated, non-ventilated and
ladder type cable troughs, in ventilated
flexible cable ways in both dry and wet
locations. Teck cable with outer jacket
is suitable for direct earth burial and for
Class II Division 2, Class III Division 1
& 2 hazardous locations per Canadian
Electric Code.
Some of the features of Teck cable
are its flexibility and ease of installation. Absence of dead air space within
cable increases heat transfer and minimize condensation. Overall protective
covering provides good environmental
protection.
Bend radii for permanent training
during installation usually varies
between 7 times to 12 times the cable
diameter depending on cable construction and manufacturer’s recommendations. Larger radii bends are
required for other conditions.
Section 12-3028 of the Canadian
Electric Code requires that the terminating fittings used must provide adequate strain relief to terminal connections and ensure electrical continuity
without injury to non-metallic sheath.

Continuity is mandatory whether or not
the armour is used as a grounding
conductor. Except for dry locations free
from corrosive atmosphere, the nonmetallic jacket is not permitted to be
stripped back to a point where armour
is exposed after installation.
Where single conductor cables carrying 200 amps or more enter metal
boxes through separate openings certain precautions are required to prevent overheating of the metal by induction. Use of non-ferrous or non-metallic
box connectors, locknuts and bushings and installation of non-magnetic
panel inserts is suggested in the code.
Please refer to the following for further
details and complete information:
1. CEC Section 12…Wiring Methods
CEC Section 4…Conductors
2. CSA C22.2 No. 131 & 131S
(Supplement #1)…Safety
Standard for Type Teck Cable
3. CSA C22.2 No. 18…Safety
Standards for Outlet Boxes,
Conduit Boxes and Fittings

Please Note
The excerpts and other material herein, whether relating
to the National Electrical Code, the Underwriters
Laboratories, Inc. listing, to industry practice or otherwise, is
not intended to provide all relevant information required for
use and installation. Reference to original or primary source
material and data is mandatory before any application or
use is made of the product.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A99

T&B ® Fittings

Metal Clad Cable Termination Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 100

T&B ® Fittings

A
Metal Clad Cable Termination Fittings
The Star ® Teck Extreme™ STE/STEX Series Cable Fitting
The Star Teck STE cable fitting series is designed for optimum integrity
in ordinary applications. The STEX series is specially designed for
classified hazardous areas. Both are designed to stand up to the
harshest and most corrosive environment.
Application
• Provides means for passing armored, metal clad, jacketed or unjacketed
and unarmored cables through a bulkhead or enclosure in hazardous
areas. (These fittings are suitable for hazardous areas when used with
T&B sealing compound.)
• Forms a mechanical grip and water and/or oil-resistant termination.
• Provides grounding continuity of cable armor.
Features
• Removable armor-stop for greater cable ranges.
• Built-in sealing device.
• Patented Elastomeric collar ring/bushing.
• Built-in jacket stripping gauge.
• Patented powergrip grounding ring.
Range
• Star Teck Extreme fittings are designed to accommodate a broad range
of cables. Each hub range overlaps the adjacent hub range, thereby
minimizing the possibility of mismatched cables and fittings in the field.
They are available in hub sizes from d" to 4" and will handle outer jacket
diameters form 0.525" to 4.340".
Materials
• Aluminum is standard material.
Cord & Cable Type
• JMC, MC
Environment Classification
• STE* Series
–Ordinary Location
–Class I, Division 2†
• –NEMA 4, 4X, 6P
• –STE050 - STE200
NEMA 6P
• –STE250 - 400
NEMA 4
• –STE050 - 400
NEMA 4X
• STEX** Series
–Ordinary Location
–Class I, Division 1, Groups A,B,C,D
–Class II, Division 1, Groups E,F,G
–NEMA 4, 4X, 6P
* These fittings are suitable for Class I hazardous locations when used in combination with a certified Class I hazardous
location sealing fitting.
** May be used in hazardous areas approved MC type cable (or equal) when installed in accordance with NEC/CEC requirements.
Not applicable to all STEX series.

A100

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 101

A
®
®

Star® Teck Extreme™ Jacketed Metal-Clad Cable Fittings
Cat.
No.

Hub Strip
Gland
Size Length Torque
a.p.†
(lb.-In.)

Range Over Jacket

Range Over Armor

Min.

Max.

Min.

Max.

A1: Throat
A2: Throat
B*
Dia. Min.
Dia. Min. Overall
w/End Stop wo/End Stop

C
Max.
Alum.

Ordinary
ST050-462*
STE050*
STE075*
STE100*
STE125*
STE150*
STE200*
STE250
STE300
STE350
STE400

STE Series
Ordinary

d
d
f
1
1b
1d
2
2d
3
3d
4

1b
1b
1b
1b
1b
1f
1f
2d
2d
2d
2d

300
300
600
700
1000
1200
1600
1600
1600
1600
1600

.525
.600
.860
.950
1.150
1.440
1.825
2.265
2.670
3.220
3.665

.650
.985
1.205
1.375
1.625
1.965
2.375
2.840
3.270
3.870
4.340

.415
.520
.780
.870
.990
1.280
1.665
2.105
2.545
3.090
3.550

.570
.895
1.125
1.295
1.465
1.805
2.215
2.680
3.145
3.640
4.225

N/A*
.505
.655
.785
.970
1.260
1.645
2.075
2.531
3.065
3.525

.395
.612
.816
1.044
1.250
1.562
1.995
2.424
2.890
3.460
3.941

2.020
2.650
2.900
3.020
4.010
4.290
4.120
5.320
5.400
5.360
5.415

1.224
1.630
2.080
2.300
2.820
3.250
3.600
4.750
5.400
5.900
6.400

1b
1b
1b
1b
1b
1f
1f
2d
2d
2d
2d
–
–

300
300
600
700
1000
1200
1600
1600
1600
1600
1600
1600
1600

.525
.600
.600
.860
.950
1.150
1.440
1.825
2.265
2.670
3.220
3.810
3.965

.650
.760
.985
1.205
1.375
1.625
1.965
2.375
2.840
3.270
3.870
4.030
4.185

.415
.490
.520
.780
.870
.990
1.280
1.665
2.105
2.545
3.090
3.680
3.835

.570
.680
.895
1.125
1.295
1.465
1.805
2.215
2.680
3.145
3.640
3.870
4.025

N/A*
N/A*
.504
.650
.834
.958
1.250
1.640
2.075
2.531
3.055
–
–

.395
.485
.678
.833
1.065
1.273
1.560
1.995
2.461
2.864
3.461
–
–

2.500
2.530
3.400
3.580
3.920
5.020
5.120
5.170
6.610
7.380
7.650
–
–

1.630
1.630
1.820
2.300
2.510
3.260
3.620
4.580
5.100
5.790
6.190
–
–

Hazardous Locations
STEX Series
Hazardous Locations

C
Collar Ring
(elastomeric)
Bushing
(elastomeric)
Gland Nut
(aluminum)
Grounding Ring
(stainless steel or
bronze with nickel plate)

B

Body
(aluminum)
Sealing Ring
(elastomeric)
Removable
Armor-Stop
(nylon d"-1")
(aluminum 1b"-4")

A1
A2

STX050-462*
STX050-464*
STEX075*
STEX100*
STEX125*
STEX150*
STEX200*
STEX250†
STEX300†
STEX350†
STEX400†
STX400-484†
STX400-485†

d
d
f
1
1b
1d
2
2d
3
3d
4
4
4

To specify other material, add the appropriate suffix to the category number.

Desired Material
Aluminum fitting with ground lock nut
Steel with zinc plate
Brass with nickle plate
Aluminum with-pvc coating
Steel with pvc coating

Suffix
GR
S
BN
PVC
S-PVC

Example
STE-050GR
STE-050S
STE-050BN
STE-050PVC
STE-050S-PVC

UL Listed #84H3
* These products are UL Listed
Watertight NEMA Type 6P
* The 1/2 fittings do not have a removable armor stop.
† CSA approved for hazardous location.

Sealing Compounds – Used for Hazardous Locations
Cat. No.
SC4-KIT
SC65

Description
Liquid type sealing compound for use in control cable applications
Putty Type Sealing Compound

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

Volume
2.8 fl. oz.
60 grams

A101

T&B ® Fittings

Metal Clad Cable Termination Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 102

T&B ® Fittings

A
Metal Clad Cable Termination Fittings
®

Star ® Teck Jacketed Metal-Clad Cable Fittings

®

Overlapping range of sizes. Star® Teck jacketed metal-clad cable fittings are
designed to accommodate a broad range of cables, thereby minimizing the possibility of mismatched cables and fittings in the field.

Easy
Installation
Exclusive
power-grip.
Provides a grip
that’s high up
on the cable –
not on the first
convolution –
so strip length
and cutting of
cable are not
critical.

Dependable
Grounding
Power-Grip
grounding ring
is non-magnetic stainless
steel. Provides
360° long-term
dependable
grounding. It
makes immediate contact with
the cable.

Application
• Provide means for passing aarmored,
metal clad, jacketed or unjacketed
and unarmored cables through a
bulkhead or enclosure in hazardous
areas (These fittings are suitable for
hazardous areas when used with T&B
sealing compound.)
• Form a mechanical grip and water
and/or oil-resistant termination
• Provide grounding continuity of
cable armor
Cord & Cable Type
• JMC, MC
Features
• Easy Installation
Exclusive power-grip. Provides a grip
that’s high up on the cable—not on
the first convolution—so strip length
and cutting of cable are not critical.
• Dependable Service
Stainless steel retaining ring.
Withstands corrosive environments.
Non-magnetic.
• Dependable Grounding
Power-Grip grounding ring is nonmagnetic stainless steel. Provides
360° long-term dependable grounding. It makes immediate contact with
the cable.

Dependable
Service
Stainless steel
retaining ring.
Withstands corrosive environments. Nonmagnetic.

Watertight
Tapered bushing. Cone
shaped to provide a secure,
tight fit while
eliminating
cupping or
water in vertical installations.

Easy to Install in
Tight Spaces
Low profile
gland nut fits
tight spaces.
Has grooves for
screwdriver
installation, and
flats for a
wrench. Durable
and reusable
with funnel entry
for easy cable
insertion.

• Watertight
Tapered bushing. Cone shaped to
provide a secure, tight fit while eliminating cupping or water in vertical
installations.
• Easy to Install in Tight Spaces
Low profile gland nut fits tight spaces.
Has grooves for screwdriver installation, and flats for a wrench. Durable
and reusable with funnel entry for
easy cable insertion.
Materials
Aluminum is standard material. The
body and gland nut on hub sizes d" to
1" are made of steel and 1b" to 4" are
made of malleable iron.
Environment Classification
• Suitable for hazardous locations.
Class 1 Div. 2; Class II Div. 2; Class III.
Where explosion proof or dust proof
fittings are required by code use Star
Teck XP fittings (STX Series).
Range
• They are available in hub sizes from
d to 4 inches, and will handle outer
jacket diameters from 0.525 to
4.340 inches.

Installing the STAR® TECK Fitting

1. Prepare cable

2. Insert cable

3. Tighten gland nut

A102

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 103

A
®
®

Star® Teck Jacketed Metal-Clad Cable Fittings

C
Retaining ring
(stainless steel)
Bushing
(neoprene)
Gland nut
(aluminum)
B

Grounding ring
(stainless steel)

Body
(aluminum)

A

Overlapping range of sizes. Star® Teck jacketed
metal-clad cable fittings are designed to
accommodate a broad range of cables, thereby
minimizing the possibility of mismatched
cables and fittings in the field. They are available in hub sizes from 1⁄2 to 4 inches, and will
handle outer jacket diameters from 0.525 to
4.340 inches.
Suitable for hazardous locations. Class 1 Div.
2; Class II Div. 2; Class III. Where explosion
proof or dust proof boxes are required by code
use Star Teck XP fittings (STX050-462 Series).

Range Over
Jacket (in.)

Cat.
No.

Hub
Size
NPT

min.

max.

A

B*

C

ST050-462
ST050-464
ST050-465
ST050-466
ST075-467
ST075-468

d
d
d
d
f
f

0.525
0.600
0.725
0.825
0.880
1.025

0.650
0.760
0.885
0.985
1.065
1.205

0.395
0.485
0.612
0.612
0.819
0.819

2.020
2.020
2.133
2.133
2.450
2.450

1.224
1.363
1.633
1.633
2.080
2.080

ST100-469
ST125-470
ST125-550
ST125-471
ST150-472
ST150-473

1
1b
1b
1b
1d
1d

1.187
1.350
1.500
1.600
1.700
1.900

1.375
1.625
1.625
1.875
1.965
2.187

1.039
1.182
1.370
1.370
1.557
1.600

2.601
3.282
3.282
3.282
3.620
3.620

2.230
2.824
2.824
2.824
3.260
3.260

ST200-551
ST200-474
ST200-475
ST200-476
ST250-477
ST250-478

2
2
2
2
2d
2d

1.900
2.100
2.300
2.500
2.380
2.580

2.187
2.375
2.565
2.750
2.640
2.840

1.715
1.995
2.057
2.057
2.230
2.430

3.640
3.640
3.640
3.640
4.700
4.700

3.620
3.620
4.020
4.020
4.750
4.750

ST300-479
ST300-480
ST300-481
ST350-482
ST350-483

3
3
3
3d
3d

2.790
3.000
3.210
3.420
3.610

3.060
3.270
3.480
3.690
3.870

2.630
2.860
3.032
3.260
3.430

4.700
4.790
4.790
4.790
4.790

5.050
5.480
5.480
5.980
5.980

ST400-484
ST400-485
ST400-486

4
4
4

3.810
3.965
4.120

4.030
4.185
4.340

3.590
3.745
3.900

4.840
4.840
4.840

6.435
6.435
6.435

Dimensions (in.)

* Approximate dimension before installation.
U.L. File No. E 38947
CSA File No. LR 23086
Suggested specifications for metal-clad cable fitting.
1. All metal-clad cable fittings for jacketed interlocked armor cable or continuous corrugated cable shall be approved by a nationally recognized testing laboratory, inspection agency or product evaluation organization.
2. Where corrugated-jacketed metal-clad cable exposed to intermittent or continuous moisture is terminated into a threaded opening, the
fitting shall be watertight type furnished with:
a. An elastomeric beveled bushing.
b. A funnel entry, splined gland nut.
c. A non-magnetic stainless steel grounding device with dual grounding action.
d. A taper threaded hub.
e. A hexagonal body and gland nut as manufactured by Thomas & Betts (aluminum series
ST050-464).
3. Where cable is terminated into a threadless opening, a suitable moisture resistant elastomeric gasket as manufactured by Thomas &
Betts, series 5262, shall be provided between the outside of enclosure and fitting shoulder.
4. With single conductor cable and/or in corrosive environments, aluminum fittings such as Thomas & Betts series ST050-464 shall be
installed.
Class I Div 2; Class II Div. 2; Class III. Where explosion-proof or dust-ignition-proof boxes are required by Teck fitting must be used in
conjunction with an approved sealing fitting.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A103

T&B ® Fittings

Metal Clad Cable Termination Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 104

T&B ® Fittings

A
Metal Clad Cable Termination Fittings
Sealing chamber is easier to
fill, requires
less sealing
compound –
saves time,
material. Flame
path is optimally designed to
allow for easy
insertion into
hub. Quick-turn
lock secures
assembly during installation.

Exclusive
Power Grip.
Provides grip
that’s high up
on cable armor
– not on first
convolution –
so precise
cable preparation is not critical. Non-magnetic stainless
steel Power
Grip grounding
ring assures
360° long-term
dependable
grounding. It
provides phenomenal tensile pullout
resistance.

Hub has
hexagonal
shape for
dependable tool
grip.

Star ® Teck XP Jacketed Metal-Clad Cable Fittings
Application
• Provide means for passing
armored, metal clad, jacketed or
unjacketed and unarmored cables
through a bulkhead or enclosure in
hazardous areas (These fittings are
suitable for hazardous areas when
used with T&B sealing compound.)
• Form a mechanical grip and water
and/or oil-resistant termination.
• Provide grounding continuity of
cable armor.
Cord & Cable Type
• JMC, MC
Features
• Sealing chamber is easier to fill,
requires less sealing compound—
saves time, material. Flame path is
optimally designed to allow for
easy insertion into hub. Quickturn lock.
• Internal splines.
• Union features twist-on action; red
color for high visibility.

Low profile
gland nut fits
tightest spaces.
Has grooves for
hammer/screwdriver installation and flats for
wrench-gripping.
Durable and
reusable with
funnel entry for
easy cable
insertion.

Internal
splines
allow
installer
to tighten
gland nut
either on
or off
enclosure.

Union features
twist-on action
for easy connection and disconnection; red
color assures
high visibility,
easy recognition. Union also
serves as a
“puller” during
disassembly.

A104

Stainless
steel retaining ring.
Withstands
corrosive
environments. Nonmagnetic.

Copper-free
construction. All-aluminum body
and gland
nut resist
corrosion,
oxidation.

Tapered
bushing.
Cone-shaped
to provide
secure, tight
fit while eliminating cupping of water
in vertical
installations.

®
®

• Exclusive Power Grip. Provides
grip that’s high up on cable armor.
Non-magnetic stainless steel
Power Grip grounding ring.
• Low profile gland nut.
Materials
Aluminum is standard material. The
body and gland nut on hub sizes d"
to 1" are made of aluminum and 1b"
to 4" are made of aluminum.
Environment Classification
• Suitable for hazardous locations.
Class 1 Div. 2; Class II Div. 2;
Class III. Where explosion proof or
dust proof fittings are required by
code use Star Teck XP fittings
(STX Series).
Range
• They are available in hub sizes
from d to 4 inches, and will handle
outer jacket diameters from 0.525
to 4.185 inches.

Easy installation saves time, money!

1. Prepare cable

2. Install Star® Teck XP on cable

3. Tighten gland nut

4. Pot cable (using liquid
or putty)

5. Install hub on enclosure

6. Insert cable and tighten
red union

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 105

A
®
®

Star® Teck XP Jacketed Metal Clad Cable Fittings

B

Hub
Grounding Ring
(aluminum) (stainless steel)

Bushing
(elastomer)

Gland Nut
(aluminum)

STX050-462

d

STX050-464

d

STX075-465
STX075-466

Range Over
Jacket (in.)

Dimensions (in.)

max.

A
min.

B

C

0.525

0.650

0.395

2.50

1.63

7

4

0.600

0.760

0.485

2.50

1.63

7

4

f

0.725

0.885

0.612

2.62

1.82

14

7

f

0.825

0.985

0.720

2.62

1.82

14

7

min.

Putty
(grams)

Liquid
(cc)

STX100-467

1

0.880

1.065

0.755

2.83

2.30

30

16

STX100-468

1

1.025

1.205

0.900

2.83

2.30

30

16

STX125-469

1b

1.187

1.375

1.062

3.05

2.51

45

22

STX150-470

1d

1.357

1.625

1.182

3.76

3.26

80

43

STX150-550

1d

1.500

1.625

1.370

3.76

3.26

80

43

STX150-471

1d

1.600

1.875

1.470

3.76

3.26

80

43

STX200-472

2

1.700

1.965

1.557

4.05

3.62

125

66

2

1.900

2.187

1.757

4.05

3.62

125

66

STX200-474

2

2.100

2.375

1.995

4.15

4.02

150

80

STX250-475

2d

2.300

2.565

2.185

4.31

4.58

341

164

STX250-476

2d

2.500

2.750

2.365

4.31

4.58

341

164

STX300-478

3

2.580

2.840

2.460

5.64

5.10

497

239

STX300-479

3

2.790

3.060

2.660

5.80

5.33

609

293

STX350-480

3d

3.000

3.270

2.864

6.32

5.79

965

464

STX350-481

3d

3.210

3.480

3.062

6.32

5.79

965

464

STX400-482

4

3.420

3.690

3.290

6.63

6.19

1323

636

STX400-483

4

3.610

3.870

3.460

6.63

6.19

1323

636

STX400-484

4

3.810

4.030

3.630

7.09

6.90

1645

791

STX400-485

4

3.965

4.185

3.775

7.09

6.90

1645

791

Retaining Ring
(stainless steel) STX200-473

U.L.
Listed
For:

Connectors When Used With Putty Type
or Liquid Type Compound

⁄2 thru 3"

Class I

Div. 2

Class II
Div. 2
Class III
Enclosure Type 4

Groups A, B,
C, D
Groups F, G

Connectors When Used With Putty Type
or Liquid Type Compound
31⁄2" & 4"

Hub
Size
N.P.T.

C

A

1

Cat.
No.

Sealing Compound
Required
SC65** SCA-KIT**

Class I
Div. 2
Class II
Div. 2
Class III
Enclosure Type 4

Groups B, C, D
Groups F, G

CSA Certified For:
Class I

Division
Groups A, B,
1 and 2
C, D
Division
Groups E,
1 and 2
F, G
Class III, SL (Integral Seal)
Enclosure Type 4
Class II

* Approximate dimension before installation.
** 1 unit of SC65 putty type sealing compound contains 50 g. 1 unit of SC4-Kit liquid type sealing compound contains 66 cc. and
includes a dispensing syringe and fibre damming material.
U.L. File No. E-38947
CSA File No. LR 23086
CAUTION: Star® Teck XP fittings must be installed with Thomas & Betts catalog numbers SC4-Kit or SC65 sealing compound (purchase
separately). See installing instructions.

Sealing Compounds
Cat. No.

Description

Volume

SC4-KIT
SC65

Liquid type sealing compound for use in control cable applications
Putty Type Sealing Compound

2.8 fl. oz.
60 grams

U.L. File No. E-82038
CSA File No. LR 638

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A105

T&B ® Fittings

Metal Clad Cable Termination Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 106

T&B ® Fittings

A
Metal Clad Cable Termination Fittings
®
®

Spin-On® Series II Connectors and Accessories

Connector
Aluminum

In corrosive environments, the T&B neoprene
boot provides maximum corrosion protection to
the connector. Simply match the connector hub
size to the boot hub size to select the proper
boot.

Cat.
No.

Hub
Size
(in.)

Cable Range
Over Armor
(in.)

A
Dia.
(in.)

B
(in.)

Optional
Corrosion
Resistant Boot
Cat. No.

2-050-008
2-050-010
2-050-020
2-050-030
2-075-040
2-075-050
2-075-060

d
d
d
d
f
f
f

.380-.435
.436-.500
.501-.580
.581-.650
.651-.730
.731-.820
.821-.880

1b
1b
1b
1b
1e
1e
1e

1g
1g
1g
1g
2a
2a
2a

NB050
NB050
NB050
NB050
NB075
NB075
NB075

2-100-070
2-100-080
2-100-090
2-100-100
2-125-110
2-125-120
2-125-130
2-150-140
2-150-150
2-150-160

1
1
1
1
1b
1b
1b
1d
1d
1d

.881-0.960
.961-1.030
1.031-1.100
1.101-1.180
1.181-1.240
1.241-1.310
1.311-1.390
1.391-1.480
1.481-1.570
1.571-1.660

2
2
2
2
2b
2b
2b
2e
2e
2e

2a
2a
2a
2a
2d
2d
2d
2e
2e
2e

NB100
NB100
NB100
NB100
NB125
NB125
NB125
NB150
NB150
NB150

2-200-170
2-200-180
2-200-190
2-200-200
2-250-210
2-250-220
2-250-230
2-250-240

2
2
2
2
2d
2d
2d
2d

1.661-1.750
1.751-1.840
1.841-1.930
1.931-2.030
2.031-2.150
2.151-2.270
2.271-2.390
2.391-2.510

3
3
3
3
3g
3g
3g
3g

2g
2g
2g
2g
3c
3c
3c
3c

NB200
NB200
NB200
NB200
NB250
NB250
NB250
NB250

2-300-250
2-300-260
2-300-270
2-300-280
2-350-390
2-350-300
2-350-310
2-350-320

3
3
3
3
3d
3d
3d
3d

2.511-2.640
2.641-2.770
2.771-2.900
2.901-3.040
3.041-3.170
3.171-3.310
3.311-3.450
3.451-3.590

4d
4d
4d
4d
5
5
5
5

3c
3c
3c
3c
3g
3g
3g
3g

NB300
NB300
NB300
NB300
NB350
NB350
NB350
NB350

2-400-330
2-400-340
2-400-350

4
4
4

3.591-3.730
3.731-3.870
3.871-4.010

5c
5c
5c

3g
3g
3g

NB400
NB400
NB400

U.L. File No. E38947
CSA File No. LR 2884

A106

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 107

A
®
®

Spin-On® X Connectors for Hazardous Locations
Cat.
No.

Compound filled connector kit.
Each SPIN-ON ® X catalog number is a complete
kit. Used to install a complete gas blocked connector in a hazardous location.
• Red anodized gland identifies the hazardous
location fitting.
• Three-piece construction; Gland-Body-Insert
with O Ring.
• Overall length 2⁄3 less than conventional.
• Installation time 50% less than conventional.
• Full tapered hub threads – gas tight thread
engagement.
• Machined Aluminum Construction, good
looks – corrosion resistance.
• Furnished complete – includes compound.
• Factory-Packaged compound – no other onsite materials.
• Sealing Compound consistency pre-mixed –
no job site variations.
• Neoprene boots available; additional corrosion protection.
• For control cable applications order liquid
compound separately.

Hub
Size
(in.)

Cable Range
Over Armor
(in.)

A Dia.
(in.)

B
(in.)

4-075-008
4-075-010
4-075-020
4-075-030
4-075-040

f"
f"
f"
f"
f"

.380-.435
.436-.500
.501-.580
.581-.650
.651-.730

1e
1e
1e
1e
1e

2a
2a
2a
2a
2a

4-100-050
4-100-060
4-100-070
4-100-080
4-125-090
4-125-100
4-125-110
4-125-120
4-150-130
4-150-140
4-150-150

1"
1"
1"
1"
1b"
1b"
1b"
1b"
1d"
1d"
1b"

.731-820
.821-880
.881-960
.916-1.030
1.031-1.100
1.101-1.880
1.181-1.240
1.241-1.310
1.311-1.390
1.181-1.240
1.241-1.310

2
2
2
2
2b
2b
2b
2b
2e
2e
2e

2a
2a
2a
2a
2d
2d
2d
2d
2e
2e
2e

4-200-160
4-200-170
4-200-180
4-200-190
4-250-200
4-250-210
4-250-220
4-250-230

2"
2"
2"
2"
2d"
2d"
2d"
2d"

1.571-1.660
1.661-1.750
1.751-1.840
1.841-1.930
1.931-2.030
2.031-2.150
2.151-2.270
2.271-2.390

3
3
3
3
3g
3g
3g
3g

2g
2g
2g
2g
3c
3c
3c
3c

4-300-240
4-300-250
4-300-260
4-300-270
4-350-280
4-350-290
4-350-300
4-350-310

3"
3"
3"
3"
3d"
3d"
3d"
3d"

2.391-2.510
2.511-2.640
2.641-2.770
2.771-2.900
2.901-3.040
3.041-3.170
3.171-3.310
3.311-3.450

4d
4d
4d
4d
5
5
5
5

3c
3c
3c
3c
3g
3g
3g
3g

4-400-320
4-400-330
4-400-340
4-400-350

4"
4"
4"
4"

3.451-3.590
3.591-3.730
3.731-3.870
3.871-4.010

5c
5c
5c
5c

3g
3g
3g
3g

Kit contains: The SPIN-ON® X connector, and new Putty Type Compound.
Suffix Cat. No. with S for steel, B for brass.
SPIN-ON® X is U.L. Listed for: Class I, Div. 2, Groups A, B, C, & D in f", 1", 1b", 1d", 2", 2d" Hub sizes. Class I, Div. 2, Groups C & D
in 3", 3d", and 4" Hub sizes. The entire line is U.L. listed for Class II, Div. 2, Groups F & G and Class III. CSA certified through 4" Hub
size for Class I, Groups A, B, C, D; Class II, Groups E, F, G; and Class III.
U.L. File No. E 82038
CSA File No. LR 638

Liquid Type Sealing Compounds
Cat. No.
SC4-KIT
SC65

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

Description
Liquid type sealing compound for use in control cable applications
Putty Type Sealing Compound
Same as Spin-On® X Blue Compound

www.tnb.com

Volume
2.8 fl. oz.
60 grams

A107

T&B ® Fittings

Metal Clad Cable Termination Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 108

T&B ® Fittings

A
Metal Clad Cable Termination Fittings
The T&B TC Series Tray Cable Connector
The Thomas & Betts TC Series of connectors are designed specifically for transitioning tray cable from horizontal cable tray to terminations in enclosures. The
precision machined aluminum interiors are ideally suited for use with sunlight-oil
resistant cable.
Application

Materials

• Provides means for passing TC type
cable from cable tray installations
into an enclosure or threaded bulkhead

Body, gland nut and insert copper free
aluminum
Environment Classification
• Ordinary Locations
• Class I, Division 2†, Groups A, B, C,
D (f" - 2d")
• Class I, Division 2, Groups C, D (3" - 4")
• Class II, Division 2, Groups F, G

Cord & Cable Type
• TC (rated for 90°C cable)
Features
• Precision machined parts
• Full tapered hub threads
• Gas tight thread engagement

Range
.225" - 3.790"

®
®

Tray Cable Connectors
Cat.
No.
4-075TC
4-100TC
4-125TC
4-150TC
4-200TC
4-250TC
4-300TC
4-350TC
4-400TC

C

A

B

A108

Hub Size

A
±.062

B
±.062

Cable Range
Dia. (inches)

f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

1.72
2.10
2.35
2.78
3.16
4.00
4.69
5.22
5.63

2.10
2.33
2.70
2.87
3.17
3.80
3.86
4.10
4.00

.275-.600
.575-.900
.860-1.180
1.095-1.420
1.280-1.780
1.700-2.200
2.150-2.700
2.650-3.230
3.180-3.790

NOTE: When installed with the two part epoxy in the intended manner the fittings are suitable for the following hazardoud locations:
f" thru 2d" – Class I Div. 2, Groups A, B, C, D
Class II Div. 2, Groups F, G
3" thru 4" – Class I Div. 2, Groups C, D
Class II Div. 2, Groups F, G.
• Suitable for use with sunlight-oil resistant tray cable
• Suitable for 90° Cable
• CSA Certified – Class I Div. 2, Groups A, B, C, D
Class II Div. 2, Groups E, F, G
Class III
• “SL” Integral Seal

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/20/03

3:05 PM

Page 109

A
Electrical Metallic Tubing (EMT)
Ref. NEC Article 348
Electrical Metallic Tubing (EMT) is similar to rigid steel conduit but is much
lighter, weighing approximately 40 percent as much as rigid steel conduit of
the same nominal size. EMT can be
used for both exposed or concealed
work provided, where during installation or afterwards, it is not subjected to
severe physical damage. Use of EMT
is restricted to systems not exceeding
600 volts and to non-hazardous locations except (Class II Division 2 NEC
Section 502-4 (b).
Galvanized Steel EMT installed in
concrete on grade or above generally
requires no supplementary corrosion
protection. However, when installed in
concrete below grade level and in contact with soil or cinders supplementary
corrosion protection consisting of a
protective coating of bitumastic or
asphalt base paint or plastic is generally applied. According to NEC Section
348-1, EMT run in or under permanently moist cinder fill must be encased in
at least two inches of cinder free concrete unless the conduit is at least 18
inches below the fill.
Aluminum EMT cannot be directly
embedded in concrete containing soluble chlorides such as calcium chloride, unwashed beach sand, sea water
or coral bearing aggregates. When
adequately treated with a protective
coating of bitumastic or asphalt base
paint or plastic coating the raceway
can be installed in concrete containing
chlorides.
NEC Sections 384-4 and 300-6
require that in wet locations where
walls are frequently washed or where
there are surfaces of absorbent material the entire wiring system including
boxes, fittings, conduits and cables
must be supported such that there is at
least 1⁄4 inch air space between it and
the supporting surface.

Connectors and couplings are
required to be of concrete tight type
when embedded in masonry or concrete or in dry locations and of the rain
tight type when installed in wet locations (NEC Section 348-8).
According to NEC Section 373-6,
where No. 4 or larger underground
conductors enter or leave a conduit, an
insulating bushing with a smooth well
rounded insulating surface must be
provided to protect conductors, unless
the terminating fitting is equipped with
an insulated throat, firmly secured in
place providing equivalent protection.
The insulating bushing or insulating
material must have a temperature rating of not less than the insulation temperature rating of installed conductors.
NEC Section 300-10 requires that
the raceways be metallically joined
together into a continuous electric conductor and must be mechanically connected to all boxes, fittings and cabinets as to provide effective electrical
continuity.
EMT is not permitted to be threaded. Cut ends of tubing are required to
be reamed. Code requires that EMT be
adequately supported and restricts
bends in one run to the equivalent of
four quarters i.e. 360 degrees total.
Portions of this section reprinted by
permission from NFPA 70-1978,
National Electrical Code®, Copyright©
1977, National Fire Protection
Association, Boston, MA.

For further details and complete information please refer to the following:
1. NEC Article 348…Electrical
Metallic Tubing
2. ANSI C80.3…Electrical Metallic
Tubing, Zinc Coated,
Specifications for
3. ANSI C33.98, UL797…Standards
for Safety. Electrical Metallic
Tubing.
4. Fittings for Rigid Metal Conduit
and Electrical Metallic Tubing,
Specifications for
5. U.L. 514B, Standards for Safety,
Outlet Boxes and Fittings
6. WW-C-563…Conduit, Metal, Rigid,
and Bend and Elbow, Electrical
Conduit, Thin-wall Type (EMT)
7. W-F-408…Fittings for Conduit,
Metal, Rigid, (Thickwall & Thinwall
(EMT) Type)
8. NEMA FB-1…Standards
Publication. Fittings and Supports
for Conduit & Cable Assemblies.
9. CEC Section 12-1500…Electrical
Metallic Tubing
10. CSA C22.2 No. 83…Safety
Standards for Electrical Metallic
Tubing
11. CSA C22.2 No. 18…Safety
Standards for Outlet Boxes,
Conduit Boxes and Fittings

Please Note
The excerpts and other material herein, whether relating to the
National Electrical Code, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise, is not intended to provide all
relevant information required for use and installation. Reference to
original or primary source material and data is mandatory before
any application or use is made of the product.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A109

T&B ® Fittings

Electrical Metallic Tubing (EMT) Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 110

T&B ® Fittings

A
Electrical Metallic Tubing (EMT) Fittings
Suggested Specifications for Electrical Metallic Tubing
(EMT) Fittings
Series 5123 Insulated
EMT Connector (Rain tight)
(Compression Type)

Series 5120
EMT Coupling (Rain tight)
(Compression Type)

Series 530
Combination Coupling
(Rain tight)
Rigid/IMC to EMT

• Ferrous Electrical Metallic Tubing
(E.M.T.) shall be of the hot dipped
galvanized type conforming to applicable specifications WW-563/ANSI
C33.98/ANSI C80.3/U.L. 797/CSA
C22.2 No. 83. E.M.T. protected solely
by enamel shall not be used.
• Where lengths of EMT are coupled
together or connected to boxes or
enclosures or where EMT is coupled
to threaded rigid metal conduit or
IMC, fittings approved for intended
applications shall be used, and:
(1) Shall be of rugged steel/malleable
iron construction electro zinc plated inside/outside including
threads. Connector throat shall be
bushed with a nylon insulator.
(2) Shall be of rain tight type for installations exposed to weather or wet
locations such as Thomas & Betts
series 5123, 5120 and 530.
(3) Shall be of concrete tight type for
installations in poured concrete
such as Thomas & Betts series
TC121, TC721, or TK121.
Rain tight type fittings may be substituted for concrete tight application.
• Where electrical metallic tubing and
associated fittings are used as part of
equipment grounding system:

Series TC121-E or TC721-E
Insulated EMT Connector
(Concrete tight)
(Set Screw Type)

(1) A bonding type locknut such as
Thomas & Betts series 106 shall
be installed where hub type fitting
terminates into a threadless
opening.
(2) Compression ring type fittings
such as Thomas & Betts series
5123 and 5120 shall be used for
terminating and coupling.
• EMT shall be securely fastened in
place at intervals as specified by the
code using straps, hangers and other
supporting assemblies as indicated
on plans, and as manufactured by
Thomas & Betts, series 4176 straps.
In wet locations or where supporting
surfaces are of absorbent materials
vertical and horizontal runs of conduit
shall be firmly supported such that
there is at least b" air space between
conduit and supporting surface.
• Spacers and supporting straps shall
be of rugged malleable iron or steel
construction hot dipped galvanized
and conforming to requirements of
Canadian Standards Association
Standard C22.2 No. 18 as manufactured by Thomas & Betts, series 4176
straps and series 1350 spacers.

Series 106
Bonding Locknut
Series TK121-E
EMT Coupling (Concrete tight)
(Set Screw Type)

Series 1350
Pipe Spacers
Series 4176
Pipe Straps
Series HT-221
Combination Coupling
(Concrete tight)
Rigid/IMC to EMT
(Set Screw Type)
Zinc Die Cast

A110

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 111

A
T&B ® Fittings

Electrical Metallic Tubing (EMT) Fittings
Fittings for Electrical Metallic Tubing (EMT)
Compression Type, Rain tight

5123 Series*

5120 Series

* 4230 Series – 90° Connectors

Application
• To connect and effectively bond
electrical metallic tubing to a box or
an enclosure.
• To provide a rain tight connection
between tubing and the connector.
• To couple ends of tubing.
Features
• Rugged all steel construction.
• Rings designed to positively bond
conduit to fitting; unique locknut
design provides effective bond
between fitting and box or enclosure;
ground continuity is assured.
• Nylon insulator firmly secured in
place – protects conductors,
reduces wire pulling effort and prevents thread damage in handling.
• Locknuts are designed with extended reach to lock fitting on to a thin
box or an enclosure.
• Locknuts tighten without deformation; will not vibrate loose.

Standard Finish
All Steel Parts .........Electro Zinc Plated
& Chromate Coated
Insulator...............................As Molded
Range
Conduit Size… d" thru 2"
Hub Size… d" thru 2" NPS
Hubs provided with straight pipe
threads NPS.
Listed/Certified by:
U.L. (U.L. File No. E-16592)
CSA (LR-4484, LR-8994)
Conforms to:
U.L. 514B
CSA C22.2 No. 18
NFPA 70-1999 (ANSI)
NEMA FB1
Federal Specification W-F-408
Federal Standard H-28 (Threads)

Standard Material
All Steel except Insulator.
Insulator.................Thermoplastic, U.L.
Rated 105°C

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A111

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 112

T&B ® Fittings

A
Electrical Metallic Tubing (EMT) Fittings
®
®

EMT Connectors – Nylon Insulated
Across
Corners

Dimensions (in.)

Cat.
No.

Size

A

B

5123
5223
5323
5423
5523
5623

d"
f"
1"
1b"
1d"
2"

1Y
1Q
1L
2h
2j
2A

1y
1B
1g
2X
2z
2m

U.L. Listed and CSA Certified rain tight.
U.L. File No. E 9043
CSA File No. 8994
®
®

EMT Couplings
Dimensions (in.)

Cat.
No.

Size

A

5120
5220
5320
5420
5520
5620

d"
f"
1"
1b"
1d"
2"

1h
1j
1L
2h
2j
2f

B
1B
2a
2a
2C
3h
3r

U.L. Listed and CSA Certified rain tight.
U.L. File No. E 9043
CSA File No. 8994
®
®

EMT Connectors
Across
Corners

Dimensions (in.)

Cat.
No.

Size

A

5121
5221
5321
5421
5521
5621

d"
f"
1"
1b"
1d"
2"

1h
1j
1L
2h
2j
2f

B
1l
1y
1f
1X
2l
2f

U.L. Listed and CSA Certified rain tight.
T&B E.M.T. (thinwall) fittings comply with Federal Spec. WF408B.
U.L. File No. E 9043
CSA File No. 8994

A112

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 113

A
®
®

Short Elbows – Insulated*
Cat.
No.
4240
4241-TB
4242
4243
4244
4245

Ideal for cramped locations or tight corners
where large radius conduit elbows will not fit or
would appear unworkmanlike. Shoulders on
body of 1⁄2" size are hex-shaped to provide positive holding for standard installation tools. Use
insulated type for simple, and safe, installations. Malleable iron. U.L. rated 105°C.

Dimension (in.)
Size

A

B

d"
f"
1"
1b"
1d"
2"

1k
1L
1g
2f
3h
3c

1s
1x
1B
2v
2f
3j

C
k
d
e
L
L
L

U.L. Listed and CSA Certified rain tight.
U.L. File No. E 09043
CSA File No. 2884

®
®

Short Elbows Malleable Iron*

Ideal for cramped locations or tight corners
where large radius conduit elbows will not fit or
would appear unworkmanlike. Shoulders on
body of 1⁄2" size are hex-shaped to provide positive holding for standard installation tools.

Dimension (in.)

Cat.
No.

Size

A

4230
4231
4232
4233
4234
4235

d"
f"
1"
1b"
1d"
2"

1k
1L
1g
2f
3h
3c

B

C

1s
1x
1B
2v
2f
3j

k
d
e
L
L
L

U.L. Listed and CSA Certified rain tight.
U.L. File No. E 09043
CSA File No. 2884

®
®

Across
Corners

For connecting EMT to threaded rigid and intermediate metal conduit.

Combination Coupling – Steel*
Dimensions (in.)

Cat.
No.

Size

A

B

530-TB
531
532

d"
f"
1"

1c
1d
1x

1h
1X
1y

U.L. Listed and CSA Certified rain tight.
U.L. File No. E 09043
CSA File No. 2884
* All items shown on this page are suitable for use in hazardous locations where general purpose equipment is specifically permitted by
the NEC; Class I, Div. 2; Class II, Div. 1 & 2; Class III, Div. 1 & 2, 502-4(a)(b); 503-3(a)(b).

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A113

T&B ® Fittings

Electrical Metallic Tubing (EMT) Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 114

T&B ® Fittings

A
Electrical Metallic Tubing (EMT) Fittings
®

Pipe Straps – Steel
Oval Hole for
Screw Size (C)

Elongated bolt hole makes alignment easy, even
when holes in mounting surface are out of alignment. Snap on features hold strap in place.

Dimensions (in.)

Cat.
No.

Size

A

B

C (Bolt Hole)

4159
4160
4161
4162
4163
4164

d"
f"
1"
1b"
1d"
2"

1B
2o
2X
2g
3L
4h

f
f
f
f
1b
1a

b
b
b
b
X
u

Not U.L. Listed
CSA File No. 2884 and 4484

®

Pipe Straps – Malleable Iron

Oval Hole for Screw Size (C)

Designed to fit each size of conduit snugly. High
reinforcing ribs on each side increase strength,
reduce weight. Hot dipped galvanized finish.

Dimensions (in.)

Cat.
No.

Size

A

4176
4177
4178
4179
4180
4181
1282
1283
1284
1285

d"
f"
1"
1b"
1d"
2"
2d"
3
3d
4"

2q
2l
3
3f
4i
5i
5n
6L
7x
8j

B

C (Bolt Hole)

y
L
f
m
n
1a
1d
1e
1f
1g

b
b
b
j
c
k
d
d
e
e

Not U.L. Listed.
CSA File No. 2884 and 4484

®

Pipe Spacers

Used with T&B conduit straps to permit space
between conduit and mounting surface.
Eliminates need for costly offset-bending conduit
and possible corrosive moisture traps when conduit is mounted directly to a surface. Malleable
iron. Hot-dipped galvanized finish, pre-mountable and stackable to eliminate offsetting.

A114

Dimensions (in.)

Cat.
No.

Size

1350
1351
1352
1353
1354

d", f", 1"
1b"-1d"-2"
2d"-3"
3d"-4"
4d"-5"-6"

A
3"
5"
9l"
7l"
10l"

B
g
1i"
1f"
2"
2l"

Conforms to NEC 300-5-C.
CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 115

A
T&B ® Fittings

Liquidtight Flexible Metal Conduit Fittings
Our Liquidtight Line is the End-All for
Liquidtight Dust-Tight Connections.
All our high-performance products are designed to deliver
excellent reliability as well as ease of installation in virtually any
application. And you benefit from our expertise through our liquidtight and dust-tight connections available for a variety of
conduits as well as portable cord.
Thomas & Betts offers the largest and most technologically
advanced line of liquidtight fittings in the industry, including
connectors for highly-specialized applications such as power
and petrochemical plants, paper mills, robot manufacturers,
packaging equipment, machine tool building, and other OEM
and MRO applications. At Thomas & Betts, we integrate the
latest manufacturing technologies with the highest quality
materials available. So you can be assured of reliable, liquidtight products that offer improved on-the-job performance
and reduced installation time and costs.
The Revolver™ Grounding Fitting Is The Latest LaborSaving Innovation From Thomas & Betts.
The Revolver liquidtight grounding fitting is our latest breakthrough in convenience to save time and money on the job.
The grounding lug of the Revolver can be rotated in a full circle, for convenient positioning that doesn’t change when you
tighten it. It’s the newest innovation in Thomas & Betts’ versatile
line of Liquidtight Connectors– fittings you can count on for
liquidtight and dust-tight connections. Because all our products revolve around your needs.
Sure-Tight Gland Cone
deflects water away from
connector and prevents
“pooling” of moisture.
Self-Cleaning Threads
inside gland nut keep dirt
and grime out of fitting.

Double Beveled Sealing
Ring cannot be installed
backwards.

Safe Edge Ground Cone
provides superior boding,
stronger pullout, easy
threading, and protects
conductors.

Precision Rolled Threads
makes installation smooth
and much easier than cut
threads.

Heat Formed Insulator curled
inside body for excellent wire
protection; will not pull out of
fitting.

Revolver™
Grounding Fitting
saves time and
money with rotating ground lug

Double Plating for superior corrosion protection;
Zinc plating with clear
Chromate finish.

Case Hardened Locknut
with Teeth provides superior strength and electrical
bonding, and can be
installed without a wrench
in the enclosure.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A115

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 116

T&B ® Fittings

A
Liquidtight Flexible Metal Conduit Fittings
Liquidtight Connectors
Liquidtight Flexible Metal Conduit
Fittings
Thomas & Betts Liquidtight fittings for
flexible metal conduits are suitable for
a wide range of installations, including
heavy industrial applications. Our
Liquidtight fittings are designed to
stand up to demanding, wet or corrosive environments, including power
and petrochemical plants, paper mills,
and anywhere high performance is a
requirement.

accepts variations in raceway convolutions and provides a positive bond.
• Continuous sealing ring which completely surrounds the conduit to
ensure a liquid-tight seal.
• Zinc chromatic plating for longer life
and exceptional appearance.
• The broadest liquid-tight line in the
industry, including PVC coated, externally grounded, aluminum series,
Chase® style, non-metallic Bullet
series, wire mesh grips, and more.

Features of Thomas & Betts Liquidtight
fittings include:
• Safe EdgeTM ground cone design that

Liquidtight Fittings for Special
Applications
The Revolver™ Externally Grounded
Fitting
The grounding lug of the new Revolver
connector can be rotated in a full circle
for convenient positioning that doesn’t
change when you tighten it. Plus, it’s
available for the first time in aluminum.
It’s a major breakthrough in convenience that saves time and money on
the job while delivering a quality connection.
Chase-Style Fittings
Where space is tight, our Chase fittings
allow for compact connections within
an enclosure.

Liquidtight Flexible Non-Metallic
Conduit Fittings
When non-metallic, Type A or EFC conduits are called for, Thomas & Betts’
XTRAFLEX System has our outstanding
Bullet fittings and conduits for liquidand dust-tight connections.
Bullet fittings:
• Feature one piece construction and a
captive o-ring for ease of installation.
• Provide a positive seal between the
conduit and the connector.
• Have a tapered thread hub and sealing o-ring for a tight seal to the box or
other enclosure.

A116

PVC-Coated Connectors
When environmental conditions are
particularly harsh and corrosive, our
PVC-coated connectors are the best
choice for both indoor and outdoor
applications. The PVC coating protects
exposed surfaces for long-lasting, reliable connections.
Sealing Gaskets
Thomas & Betts sealing gaskets are
resistant to oil, coolants, and hydraulic
fluids as well as water, with a stainless
steel retaining clip that assures a quality seal. They’re the ideal match to our
Liquidtight connectors for a safe and
secure seal.

• Are constructed of non-burning, nondripping thermoplastic for high
strength chemical resistance.
• Feature a smooth insulated body for
maximum dielectric strength.
• Have a patented, serrated design
that provides high mechanical pullout
strength.
• Include a complete range of flexible,
non-metallic conduits – including both
smooth and corrugated varieties – to
complete our XTRAFLEX System.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 117

A
Liquidtight Flexible Metal Conduit Connectors

5331 Series*
5231 AL Series

5361 Series

5271 Series
* 5341 Series…
same as 5331, except 45° Connectors
5351 Series…
same as 5331, except 90° Connectors

Predetermined
Compression

5361 Series
Chase® Style

Application
• Used where flexible metal raceway is
installed in outdoor or indoor locations where exposed to continuous or
intermittent moisture.
• To positively bond conduit to box or
enclosure.
Features
• Ability to install quickly with low
torque effort.
• Ground cone design offers following
advantages:
(1) Compresses metallic convolutions; provides high quality
ground contact with low impedance and high raceway holding
power (A).
(2) Single helical thread on ground
cone is easy to install without
cross thread; accepts variations in
raceway diameters and convolution pitch (B).
(3) Rolled over edge protects conductors (C).
Sealing ring design has following
exclusive features:
(1) Grips and seals at leading and
trailing edge – will not abrade
raceway jacket (D).
(2) Provided with grooves on inside
diameter for anti-sleeving (E).
(3) Shoulders on both ends for extra
sealing (F).
(4) Symmetrical shape assures foolproof assembly.
• Can be disconnected and reused.
• Watertight/oil tight installation at box or
enclosure termination is assured by:
(1) External taper thread hub on 5331
series and use of sealing gasket
5262 series (G).
(2) Captivated sealing ‘O’ ring on
5361 series (H).
(3) Taper tapped hole on 5271 series.
• Suitable for use in Class I Division 2,
Class II Division 1 and 2 and Class III
Division 1 and 2 Hazardous
Locations per N.E.C. Section 500.
• Suitable as a grounding means per
N.E.C. Section 351-9 (up to 1b" trade
size on).
• d" & 1b" sizes Laboratory tested to
carry ground fault current of up to
1000 amps RMS with duration of fault
current 3 cycles.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

• Conforms with JIC requirements.
• Available with imperial, I.S.O. & PG
threaded hub.
Standard Material
5331-5361-5271 Series
Body, Gland, Locknut & Ground Cones:
All steel or malleable iron.
Sealing Ring and Insulator: All thermoplastic
Sealing Gasket: Stainless Steel and
Buna N
5231 AL Series
All Copper-free Aluminum (noninsulated)
5332SST Series
31L Stainless Steel insulated
5332B Series
Marine grade brass insulated avant
Standard Finish
5331-5361-5271 Series
Electro Zinc Plated & Chromate Coated
5231 AL Series
Copper-free Aluminum
Range
5331 Series ..............c" thru 6"* conduit
5341 Series................c" thru 4" conduit
5351 Series................c" thru 4" conduit
5361 Series................c" thru 4" conduit
5271 Series..............c" thru 11⁄4" conduit
5231 AL Series ..........c" thru 4" conduit
5332SST Series.............d" & f" conduit
5332B Series.................d" & f" conduit
All hubs provided with taper pipe
threads (NPT)
Listed/Certified by:
U.L.…(U.L. File No. E-23018)
CSA…(LR-2884, LR-4484, LR-9555)
Conforms to:
U.L. 514B
CSA C22.2 No. 18
NEMA FB-1
NFPA 70-1999 (ANSI)
JIC EGP1
JIC EMP1
Federal Specification W-F-406
Federal Standard H-28 (Threads)

A117

T&B ® Fittings

Liquidtight Flexible Metal Conduit Fittings

412031.A02 FIT 3/5

3/20/03

3:05 PM

Page 118

T&B ® Fittings

A
Liquidtight Flexible Metal Conduit Fittings
®
®

Straight Connectors*
Cat. No.
Insulated
Steel
‡

Steel malleable iron, or aluminum tapered hub
threads. With safe-edge ground thru 4" cone
and double bevel seating ring (through 2").

5229
5330‡
5331†**
5332†
5333†
5334†
5335†
5336
5337
5338
5339
5340
5385‡
5386‡

Dimensions (in.)

Aluminum

Non-Insulated
Steel

Stainless
Steel

Brass

Conduit
Size

A

B

C

–
–
5231AL
5232AL
5233AL
5234AL
5235AL
5236AL
5237AL
5238AL
5239AL
5240AL
–
–

–
–
5231†
5232†
5233†
5234†
5235†
5236
5237
5238
5239
5240
5285
–

–
–
–
5332SST
5333SST
–
–
–
–
–
–
–
–
–

–
–
–
5332B
5333B
–
–
–
–
–
–
–
–
–

b
j
c
d
f
1
1b
1d
2
2d
3
4
5
6

B
©
1q
1c
1y
1g
2s
2z
3b
3f
4d
5d
8f
8f

1c
1c
1d
1l
1e
2h
2d
2L
3h
4a
4b
4d
7
8d

v
v
l
l
l
f
m
m
g
1
1
1a
1g
2

®
®

45° Angle Connectors*
Cat. No.
Insulated
†

Malleable iron, tapered hub threads. With safeedge ground cone and double bevel sealing
ring (through 2").

5341 **
5342†
5343†
5344†
5345†
5346
5347
5348
5349
5350

Non-Insulated
†

5241
5242†
5243†
5244†
5245†
5246
5247
5248
5249
5250

Conduit
Size
c
d
f
1
1b
1d
2
2d
3
4

Dimensions (in.)
A
1q
1c
1y
1g
2s
2z
3b
3f
4d
5d

B

C

1l
1g
2a
2b
2f
3c
3g
4b
4b
4e

l
l
l
f
m
m
g
1
1
1a

* Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 1 and 2; Class III, Div. 1 and 2, where general purpose equipment is
specifically permitted per NEC Section 500-2(a).
** c" Conduit Fitting has d" hub.
†
U.L. Listed as grounding means under NEC 351-7.
‡
Not U.L. Listed.
Note: U.L. Listed liquidtight; and CSA Certified watertight.
Available with DURA-PLATE® Finish.
U.L. File No. E-23018
CSA File No. 2884

For Wiremesh Grips refer to pages A119, A154.

A118

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 119

A
®
®

Standard Liquid Tight – Female Hub Adapter
Cat. No.

†

5271
5272†
5273†
5274†
5275†
†

Dimensions (in.)

Conduit
Size

A

B

c
d
f
1
1b

1q
1c
1y
1g
2s

1l
1W
1f
2a
2d

U.L. Listed as grounding means under NEC 351-7.

®
®

90° Angle Connectors
Cat. No.
Insulated
5351
5352
5353
5354
5355
5356
5357
5358
5359
5360

Non-Insulated

Aluminum

Hub
Size

Conduit
Size

5251
5252
5253
5254
5255
5256
5257
5258
5259
5260

5251AL
5252AL
5253AL
5254AL
5255AL
5256AL
5257AL
–
–
–

d"
d"
f"
1"
1b"
1d"
2"
2d"
3"
4"

c"
d"
f"
1"
1b"
1d"
2"
2d"
3"
4"

Dimensions (in.)
A
1q
1c
1y
1g
2s
2z
3b
3f
4d
5d

B

C

1c
1l
1f
2i
2f
2n
3k
8g
10b
12e

l
l
l
f
m
m
g
1
1
1a

* Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 1 and 2; Class III, Div. 1 and 2, where general purpose equipment is
specifically permitted per NEC Section 500-2(a).
** c" Conduit Fitting has d" hub.
†
U.L. Listed as grounding means under NEC 351-7.
‡
Not U.L. Listed.
Note: U.L. Listed liquidtight; and CSA Certified watertight.
Available with DURA-PLATE® Finish.
U.L. File No. E-23018
CSA File No. 2884

For Wiremesh Grips refer to pages A119, A154.

®
®

Wiremesh Grips for Liquidtight Fittings
Cat.
No.

Prevents severe conduit bends and pullout.

Conduit
Size

Liquidtight Connectors
Straight

45°

90°

90°
Chase

Chase

Adapter

WMG-LT1
WMG-LT2
WMG-LT3

c"
d"
f"

5331
5332
5333

5341
5342
5343

5351
5352
5353

5361
5362
5363

5371
5372
5373

5271
5272
5273

WMG-LT4
WMG-LT5
WMG-LT6

1"
1b"
1d"

5334
5335
5336

5344
5345
5346

5354
5355
5356

5364
5365
5366

5374
–
–

5274
5275
5276

WMG-LT7
WMG-LT8
WMG-LT9
WMG-LT10

2"
2d"
3"
4"

5337
5338
5339
5340

5347
5348
5349
5350

5357
5358
5359
5360

5367
5368
5369
5370

–
–
–
–

5277
5278
5279
5282

Order wiremesh grip separately: no need to duplicate inventory.
U.L. File No. E23018
CSA File No. 2884 & 4484

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A119

T&B ® Fittings

Liquidtight Flexible Metal Conduit Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 120

T&B ® Fittings

A
Liquidtight Flexible Metal Conduit Fittings
External Bonding Liquidtight Flexible Metal Conduit Connectors

Series 5331GR

Sleeving
Raceway Jacket pulls off – exposing core and
affecting liquidtight termination. Feature (E) on
sealing ring helps overcome this problem.

A120

Application
• Used where external bonding jumper
is required around liquidtight flexible
metal conduit.
• To positively bond conduit to box or
enclosure.
• Used where flexible raceway is
installed in outdoor or indoors location where exposed to continuous or
intermittent moisture.
Features
• Designed with provision to install
bonding jumper in several positions.
• Designed to accept mechanical or
compression lug.
• Ability to install quickly with low
torque effort.
(i) Compressed metallic convolutions; assures ground contact with
low impedance and high raceway
holding power (A).
(ii) Single helical thread on ground
cone is easy to install without
cross thread; accepts variations in
raceway diameters and convolution pitch (B).
(iii) Rolled over edge protects conductors (C).
• Sealing ring design has following
exclusive features:
(i) Grips and seals at leading and
trailing edge – will not abrade
raceway jacket (D).
(ii) Provided with grooves on inside
diameter for anti-sleeving (E).
(iii) Shoulders on both ends for extra
sealing (F).
(iv) Symmetrical shape assures foolproof assembly.
• Can be disconnected and reused.
• Watertight/oil tight installation at box or
enclosure termination is assured by:
1. External taper thread hub on
5331GR series and use of sealing
gasket 5262 series (G).
2. Taper tapped hole on 5271 series.
• Suitable for use in Class I Division 2,
Class II Division 1 & 2 and Class III
Division 1 & 2 Hazardous Locations
per NEC Article 500.

• Suitable as a bonding means per
U.L. 467 and NEC Article 351-9.
• Conforms with JIC requirements.
Standard Material
Lugs: High conductivity copper (for
copper conductor only).
Body, Gland, Locknut & Ground Cones:
All steel or malleable iron.
Sealing Ring and Insulator: All thermoplastic.
Sealing Gasket: Stainless Steel and
Santoprene.
Strap: Steel.
Standard Finish
All Electro Zinc Plated and Chromate
Coated except lugs.
Lugs: Bright Dipped.
Range
5331GR Series (straight connectors
with male hub): c" thru 6" conduit.
5341GR Series (45°): c" thru 4" conduit.
5351GR Series (90°): c" thru 4" conduit.
5232ALGR Series: c" thru 1" conduit.
All hubs provided with taper pipe
threads (NPT).
Listed/Certified by:
U.L. File #E-23018
CSA
Conforms to:
U.L. 467
U.L. 514B
CSA C22.2 No. 18
CSA22.2 No. 41
NEMA FB-1
NFPA 70-1999 (ANSI)
JIC EGP1
JIC EMP1
Federal Specification W-F-406
Federal Standard H-28 (threads)
1

Per C.E. Code, this method
is not permissible.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 121

A
®
®

Straight Grounding Fittings*
Cat. No.
Steel
Insulated

A

C

B

Malleable iron, tapered hub threads.

Steel
Non-Insulated

Aluminum
Non-Insulated

5331GR**

5231GR

5231 ALGR

5332GR

5232GR

5232ALGR

5333GR

5233GR

5233ALGR

5334GR

5234GR

5234ALGR

5335GR
5336GR

A

B

C

Ground
Wire
D

c"

1q

1d

l

14-8

d"

1c

1l

l

14-8

f"

Dimensions (in.)

Conduit
Size

1y

1e

l

14-4

1"

1g

2h

f

14-4

5235GR

1b"

2b

2d

m

8-1/0

5236GR

1d"

3b

2L

m

4-2/0

5337GR

5237GR

2"

3m

3h

g

4-2/0

5338GR

5238GR

2d"

4k

4a

5339GR

5239GR

3"

5i

5340GR

5240GR

4"

6a

5385GR

5285GR

5"

8l

5386GR

–

6"

8w

1

2-4/0

4b

1

2-4/0

4d

1a

2-4/0

7

1g

2-4/0

8d

2

2-4/0
®
®

45° Angle Grounding Fittings
Cat. No.

Ground Wire

Insulated

Max. over Ribs

Malleable iron, tapered hub threads.

5341GR**
5342GR
5343GR
5344GR
5345GR
5346GR
5347GR
5348GR
5349GR
5350GR

Non-Insulated

Conduit
Size

5241GR**
5242GR
5243GR
5244GR
5245GR
5246GR
5247GR
5248GR
5249GR
5250GR

c"
d"
f"
1"
1b"
1d"
2"
2d"
3"
4"

Ground
Wire
D

Dimensions (in.)
A

B

C

1q
1c
1y
1g
2b
3b
3m
4k
5i
6a

1l
1g
2a
2b
2f
3c
3g
4b
4b
4e

l
l
l
f
m
m
g

14-8
14-8
14-4
14-4
8-1/0
4-2/0
4-2/0
2-4/0
2-4/0
2-4/0

1
1
1a

®
®

90° Angle Grounding Fittings
Cat. No.
Steel
Insulated

Ground Wire

Max. over Ribs

Malleable iron tapered hub threads.

5351GR**
5352GR
5353GR
5354GR
5355GR
5356GR
5357GR
5358GR
5359GR
5360GR

Steel
Non-Insulated

Aluminum
Non-Insulated

Conduit
Size

A

B

C

Ground
Wire
D

5251GR**
5252GR
5253GR
5254GR
5255GR
5256GR
5257GR
5258GR
5259GR
5260GR

5251ALGR
5252ALGR
5253ALGR
5254ALGR

c"
d"
f"
1"
1b"
1d"
2"
2d"
3"
4"

1q
1c
1y
1g
2b
3b
3m
4k
5i
6a

1b
1k
1m
2h
2d
2n
3k
8g
10b
12e

l
l
l
f
m
m
g
1
1
1a

14-8
14-8
14-4
14-4
8-1/0
4-2/0
4-2/0
2-4/0
2-4/0
2-4/0

Dimensions (in.)

** c" conduit fittings have d" trade size hub. With safe-edge ground cone (through 4") and double bevel sealing ring (through 2").
U.L. Listed liquidtight; and CSA Certified watertight. Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 1 and 2; Class
III, Div. 1 and 2, where general purpose equipment is specifically permitted per NEC Section 500-2(a). Available with DURA-PLATE® Finish.
U.L. File No. E 3060. CSA File No. 638
Note: c"-1" fittings include Revolver™ grounding device. For sizes 1b" and up, fittings are supplied with a copper mechanical lug.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A121

T&B ® Fittings

Liquidtight Flexible Metal Conduit Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 122

T&B ® Fittings

A
Liquidtight Flexible Metal Conduit Fittings
®
®

Swing
Radius

Bolt

External Grounding Strap
Cat.
No.
GR1W
GR2W
GR3W
GR4W
GR5W

For retrofit applications. Includes strap, nut
and bolt.

A122

Conduit
Size

A

B
Bolt Size

c"
d"
f"
1"
1b"

1
1h
1c
1d
1g

10-24
10-24
b-20
b-20
j-18

U.L. File No. E-3060
CSA File No. 638

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 123

A
Liquidtight Flexible Metal Conduit Connectors (PVC Coated)

3321 Series*
*3361 Series...
same as 3321, except 90°
3341 Series...
same as 3321, except 45°

Gland
(F)
Leading
Edge
Sealing Ring

Raceway Core
Convolutions
(E)
(B)
(C)

(G)
Ground Cone

(A)

(D)
(F)
(Trailing
Edge)

(B)
(A)
(B)

Body

(I)
Taper Threaded Hub

Sealing
Gasket

Locknut

(H)

3321 Series

Application
• Used where liquidtight flexible metal
conduit is installed in outdoor or
indoor locations where exposed to
environmental conditions that are
more than normally corrosive to
exposed surfaces.
• To positively bond conduit to box or
enclosure.

• Suitable for use in Class I Division 2,
Class II Division 1 & 2 and Class III
Division 1 & 2 Hazardous Locations
per N.E.C. Article 500.
• Suitable as a grounding means per
N.E.C. Section 351-9 (up to 1b"
trade size).
• Conforms with JIC requirements.

Features
• PVC coated to protect connector
from extremely corrosive surroundings without effecting integrity of
electrical grounding path (A).
• Provided with overlapping sleeve
for additional seal (B).
• Ability to install quickly with low
torque effort.
• Ground cone design offers following
advantages:
(1) Compresses metallic convolutions; provides high quality
ground contact with low impedance & high raceway holding
power (C).
(2) Single helical thread on ground
cone is easy to install without
cross threading; accepts variations in raceway diameters and
convolution pitch (D).
(3) Rolled over edge protects conductors (E).
• Sealing ring design has following
exclusive features:
(1) Grips and seals at leading and
trailing edge – will not abrade
raceway jacket (F).
(2) Provided with grooves on inside
diameter for anti-sleeving (G).
(3) Shoulders on both ends for extra
sealing.
(4) Symmetrical shape assures foolproof assembly.
• Hardened steel or malleable iron
locknut (H).
• Can be disconnected and reused.
• Watertight/oil tight installation at box
or enclosure termination is provided
by – external taper thread hub and
sealing gasket (I).

Body, Gland, Locknut & Ground
Cones: All steel or malleable iron.
Sealing Ring and Insulator: All thermoplastic.
Sealing Gasket, Retainer – Stainless
Steel: Resilient Seal: Santoprene.
Coating – PVC.
Outside of body & gland…PVC
Coated.
Inside of body & gland…Electro Zinc
Plated & Chromate Coated.
Locknut & Sealing Gasket,
Retainer…Electro Zinc Plated
& Chromate Coated.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

Standard Material

Range
3321, 3361 & 3341 Series…c" thru 4"
conduit.
All hubs provided with taper pipe
threads (NPT).
Listed/Certified by:
U.L.........................(U.L. File E23018)
CSA ....................(LR-2884, LR-4484)
Conforms to:
U.L. 514B
CSA C22.2 No. 18
NEMA FB-1
NFPA 70-1999 (ANSI)
JIC EGP1
JIC EMP1
Federal Specification W-F-406
Federal Standard H-28 (THREADS)

A123

T&B ® Fittings

Liquidtight Flexible Metal Conduit Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 124

T&B ® Fittings

A
Liquidtight Flexible Metal Conduit Fittings
®
®

Corrosion Resistant PVC Jacketed Liquidtight Connectors
Cat.
No.

Straight PVC Coated
Nylon Insulated
Steel or Malleable
NPT hub threads

45° PVC Coated
Nylon Insulated
NPT hub threads

90° PVC Coated
Nylon Insulated
NPT hub threads

A124

Conduit
Size

A

B

C

Straight PVC Coated
3321†
3322†
3323†
3324†
3325†
3326
3327
3328
3329
3331

c"
d"
f"
1"
1b"
1d"
2"
2d"
3"
4"

1v"
1e"
1n"
2b"
2L"
3a"
3e"
4c"
5i"
6k"

2j"
2d"
2A"
3v"
4b"
4L"
5j"
6c"
6d"
6f"

l"
l"
l"
f"
m"
m"
g"
1"
1"
1a"

45° PVC Coated
3341†
3342†
3343†
3344†
3345†
3346
3347
3348
3349
3352

c"
d"
f"
1"
1b"
1d"
2"
2d"
3"
4"

1v
1e"
1n"
2b"
2L"
3a"
3e"
4c"
5i"
6k"

1a"
1b"
1k"
1m"
2h"
2L"
3i"
3m"
4l"
5f"

l"
l"
l"
f"
m"
m"
g"
1"
1"
1a"

90° PVC Coated
3361†
3362†
3363†
3364†
3365†
3366
3367
3368
3369
3371

c"
d"
f"
1"
1b"
1d"
2"
2d"
3"
4"

1v"
1e"
1n"
2b"
2L"
3a"
3e"
4c"
5i"
6k"

2i"
2d"
2C"
3x"
4d"
4n"
5L"
11a"
12d"
14g"

l"
l"
l"
f"
m"
m"
g"
1"
1"
1a"

† U.L. Listed as grounding means per NEC. SECT. 351.7
Complies with J.I.C. standards and Federal Specs WF 406B, WF 408B
Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 1 and 2; Class III, Div. 1 and 2, where general purpose equipment is
specifically permitted per NEC Section 500-2(a).
Meets Coast Guard CG293
U.L. File No. E 23018
CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 125

A
T&B ® Fittings

Liquidtight Flexible Metal Conduit Fittings
Liquidtight Union for Threaded Hub
Application
• To couple threaded end of a fitting or
a pipe to a tapped opening in a box
or enclosure where rotation of fitting
or pipe is limited or restricted.

41 Series

(B)
Controlled Deformation
of Resilient Seal
(E)

(C)

(D)

Gland

Resilient Seal
(A)

Features
• Design provides high quality bond
between fitting or pipe to the union.
• Provided with resilient seal (A).
• Resilient seal subjected to controlled
deformation; positive seal and
reusability are assured (B).
• Unique design centralizes throat openings of threaded hub and union (C).
• Permits orientation of fitting in any
predetermined direction for a safe,
functional and neat assembly.
• Provided with taper threaded hub for
liquidtight assembly (D).
• Straight pipe threads on gland accept
a straight or taper threaded hub on fitting or pipe to be coupled (E).
• Suitable for hazardous location use
per NEC Article 501 Class I, Division
2, Article 502 Class II, Division 1 & 2
and Article III Division 1 & 2.

Standard Material/Finish
Gland…Steel/Electro Zinc Chromate
Coated
Body…Steel/Electro Zinc Chromate
Coated
‘O’ Ring…Buna N/As Molded
Range
Hub (External Thread)…d" & f" NPT
Gland (Internal Threads)…d" & f" NPS
Listed/Certified by:
U.L.…(U.L. File No. E-23018)
CSA…(LR-2884, LR-4484)
Conforms to:
U.L. 514B
CSA C22.2 No. 18
NEMA FB1
NFPA 70-1999 (ANSI)
Federal Standard W-F-408
Federal Standard W-F-406
Federal Standard H-28 (Threads)
Note: For additional product information
refer to Thomas & Betts publication 600.1

Body

®
®

Liquidtight Union for Threaded Hub

Steel, zinc plated and chromated. Ideal for
angle fittings where swing clearance is not
available.

Cat.
No.

Conduit
Size

A

B

41-TB
42-TB

d"
f"

1S"
1n"

1"
1b"

U.L. File No. E 23018
CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A125

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 126

T&B ® Fittings

A
Liquidtight Flexible Metal Conduit Fittings
Liquidtight Flexible Non-Metallic Liquidtight Type A
Conduit Connectors

Series 6302
Liquidtight Flexible Non-Metallic
Conduit Connectors

Series 6322
Liquidtight Flexible Non-Metallic
Conduit Connectors

Application
• To provide a liquidtight, dust tight
connection between flexible, nonmetallic conduit and a box or an
enclosure.

Standard Material

Features
• Serrated, design provides high
mechanical pullout strength (A).
• Unique component parts (body/gland) design insures positive seal
between conduit and connector (B).
• Tapered thread hub and sealing ‘O’
ring provide a liquidtight/dust tight
seal to a box or an enclosure (C).
• High strength, chemical resistant,
non-burning, non-dripping thermoplastic construction.
• Smooth insulated body throughout for
maximum dielectric strength.
• Captive ‘O’ ring and reduced number
of parts save installation time (D).

Standard Finish

Body…Thermoplastic
Gland…Thermoplastic
‘O’ Ring…Neoprene
Locknut…Steel (Case Hardened)
Body, Gland & ‘O’ Ring .......As Molded
Locknut ..............................Electro Zinc
Range
Conduit Size ........................d" thru 1b"
Hub Size ....................d" thru 1b" N.P.T.

®

Thermoplastic Fittings for Liquidtight Flexible
Non-Metallic Conduit Type A
Corrosion Resistant Applications
90° Angle Connector
Conduit
Size

A

B

C
Cross
Corners

Straight Connector
6302
6303
6304
6305

d"
f"
1"
1b"

.60"
.61"
.77"
.79"

1.68"
1.85"
1.89"
2.30"

1.48"
1.76"
2.10"
2.67"

90° Angle Connector
6322
6323
6324
6325

d"
f"
1"
1b"

.60"
.61"
.77"
.79"

1.56"
1.74"
1.78"
2.13"

1.48"
1.76"
2.10"
2.67"

Cat.
No.

Straight Connector

Designed especially for the Type A, all plastic
raceways now in use for dynamic machine tool
applications.
Fittings are constructed of a high-strength,
chemically resistant thermoplastic tougher than
the raceway itself.
Neoprene sealing ring is furnished with connector providing a liquidtight seal for knockout
applications.

A126

Meets Coast Guard CG293
U.L. File No. E 23018

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 127

A
®

Steel/Malleable Iron Liquidtight Flexible
Non-Metallic Conduit Type A
Cat.
No.

• Nylon insulated throat.
• T&B Sealing Ring to seal knockouts.
• Steel or malleable iron.
• U.L. Listed.
• NPT hub threads to seal in female threads.
• High mechanical pull-out strength.
• Provides positive seal against water, oil
and dust.

3720-TB*
3721-TB
3722-TB
3723
3724-TB
3725
3726

Conduit
Size

Hub Thread

c"
d"
f"
1"
1b"
1d"
2"

d – 14 NPT
d – 14 NPT
f – 14 NPT
1 – 11d NPT
1b – 11d NPT
1d – 11d NPT
2 – 11d NPT

A

B

1q"
1c"
1e"
1g"
2c"
2f"
3w"

2"
2a"
2b"
2d"
2"
3c"
3e"

* Not U.L. Listed
U.L. File No. E 23018
See charts below for 45 and 90 degree fittings for this series

®

45° Metallic Connector for Non-Metallic Conduit Type A
Cat.
No.
3730-TB*
3731-TB
3732
3733-TB
3734-TB
3735-TB
3736

Conduit
Size

Hub Thread

c"
d"
f"
1"
1b"
1d"
2"

d – 14 NPT
d – 14 NPT
f – 14 NPT
1 – 11d NPT
1b – 11d NPT
1d – 11d NPT
2 – 11d NPT

A

B

1q"
1c"
1e"
1g"
2c"
2f"
3w"

2u"
2l"
3"
3d"
4a"
4g"
5d"

* Not U.L. Listed
U.L. File No. E 23018
®

90° Metallic Connector for Non-Metallic Conduit Type A
Cat.
No.
3740*
3741
3742
3743-TB
3744-TB
3745
3746-TB

Conduit
Size
c"
d"
f"
1"
1b"
1d"
2"

Hub Thread

A

B

d – 14 NPT
d – 14 NPT
f – 14 NPT
1 – 11d NPT
1b – 11d NPT
1d – 11d NPT
2 – 11d NPT

1q"
1c"
1e"
1g"
2c"
2f"
2w"

1e"
1f"
2b"
2l"
3b"
3d"
4a"

* Not U.L. Listed
U.L. File No. E 23018

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A127

T&B ® Fittings

Liquidtight Flexible Metal Conduit Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 128

T&B ® Fittings

A
Liquidtight Flexible Metal Conduit Fittings
Liquidtight Sealing Gasket

5262 Series

Application
• When used with an externally threaded connector provides a tight seal
against oil, fumes or moisture at the
knockout opening.

Stainless Steel Retainer

Resilient Sealing
Material Locked in Steel Retainer

Features
• Design locks resilient sealing material in steel.
• Steel retainer protects seal from
extruding out under torque and limits compression to an optimum predetermined value; provides high
quality seal.
• Resilient material flows and seals
rough surfaces.
Standard Material
Retainer .........................Stainless Steel
Sealing Material..................Santoprene
Thermoplastic Rubber

Resilient Seal

Range
d" thru 4" Hub Size
®
®

Sealing Ring with Stainless Steel Retainer
Cat.
No.

B Thickness

NEMA 3R, 4, 6 & 13
For use with T&B Fittings. Sealing material
resists oil, coolants, and hydraulic fluids as
well as water.

Dimension (in.)

Conduit
Size

A

B

b"
c"
d"
f"
1"
1b"
1d"
2"
2d"
3"
4"

.80"
.95"
1.16"
1.49"
1.75"
2.15"
2.42"
2.92"
3.44"
4.08"
5.29"

.11"
.11"
.18"
.19"
.19"
.22"
.23"
.23"
.23"
.23"
.31"

5299**
5261**
5262
5263
5264
5265
5266
5267
5268
5269
5270
** U.L. not applicable
U.L. File No. E 13938
CSA File No. 2884

®
®

A

NEMA 3R, 4, 6 & 13
Made of flame retardant neoprene, these new
K.O. plugs meet U.L. 514 flammability test.
They provide a raintight, dust, and oil-tight reusable seal for electrical knockouts. NEMA 3R,
4, 6 & 13 boxes can be saved or re-used whenever a K.O. is no longer used. No tools needed
to install; just push into hole … they snap in.
Temperature range – 30°C to 105°C.

Liquidtight K.O. Plug
Cat.
No.

Size

5710
5711
5712
5713
5714
5715
5716
5717
5718

d"
f"
1"
1b"
1d"
2"
2d"
3"
4"

A
1s"
1d"
1B"
2r"
2d"
3p"
3y"
4∫"
5∫"

U.L. Listed raintight
CSA not applicable
Meets Coast Guard Regulation CG293
U.L. File No. E 13938
CSA File No. 2884

A128

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 129

A
®
®

ISO Metric Thread Liquidtight Fittings*
Cat.
No.

Flexible
Conduit
Size

Nylon insulated straight connectors
9330
b"
9331
b"
9306
j"
9360
3c"
9361
c"
9362
d"
9363
f"
9364
1"
Nylon insulated 45° angle connectors
9340
c"
9341
c"
9342
d"
9343TB
f"
9344
1"
Nylon insulated 90° angle connectors
9350
c"
9351
c"
9352TB
d"
9353TB
f"
9354TB
1"

Fittings for Liquidtight flexible metal conduit
with metric threads of ISO Form (BS-4568-SA
BS 162).

Metric
ISO
Thread

A
mm

B
mm

C
mm

16
20
16
16
20
20
25
32

36
36
36
40
40
42
45
54

21
21
26
29
29
35
42
47

12
12
12
16
16
16
16
23

16
20
20
25
32

27
27
27
31
34

29
29
35
42
47

16
16
16
16
23

16
20
20
25
32

35
35
39
43
48

29
29
35
42
47

16
16
16
16
23

U.L. Listed Liquidtight.
CSA certified watertight.
* All items shown on this page are suitable for use in hazardous location where general purpose equipment is specifically permitted by
the NEC; Class I Div. 2, Class II, Div. 1 & 2; Class III, Div. 1 & 2, NEC 501-4(b); 502-4(a)(b); 503-3(a)(b).
U.L. File No. E 23018
CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A129

T&B ® Fittings

Liquidtight Flexible Metal Conduit Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 130

T&B ® Fittings

A
Liquidtight Flexible Metal Conduit Fittings
®
®

PG Metric Thread Liquidtight Fittings*
Flexible
Conduit
Size

Cat.
No.

Fittings for Liquidtight flexible metal conduit
with metric threads of PG Form (DIN 40430).

Nylon insulated straight connectors
7330
b"
7331
b"
7360
j"
7361
c"†
7362
c"†
7363
1d"†
7364
f"†
7365
1"†
7366
1b"†
7367
1d"
7368
2"
Nylon insulated 45° angle connectors
7341
c"†
7342
c"†
7343
d"†
7344-TB
f"†
7345
1"
7346
1b"†
7347
1d"
7348-TB
2"
Nylon insulated 90° angle connectors
7351
c"†
7352
c"†
7353
d"†
7354
f"†
7355
1"†
7356
1b†
7357
1d"
7358
2"

Metric
PG
Thread

A
mm

B
mm

C
mm

9
11
9
11
13.5
16
21
29
36
42
48

36
36
36
40
40
41
43
56
67
72
81

21
21
26
29
29
35
42
47
58
69
83

12
12
12
14
14
14
14
19
21
21
21

11
13.5
16
21
29
36
42
48

27
27
30
34
44
51
60
73

29
29
35
42
47
58
69
76

14
14
14
14
19
19
21
24

11
13.5
16
21
29
36
42
48

37
37
40
44
56
70
75
87

29
29
35
42
47
58
69
83

14
14
14
14
21
21
21
24

* All items shown on this page are suitable for use in hazardous location where general purpose equipment is specifically permitted by
the NEC; Class I Div. 2, Class II, Div. 1 & 2; Class III, Div. 1 & 2, NEC 501-4(b); 502-4(a)(b); 503-3(a)(b).
U.L. Listed as grounding means under NEC 351-7.
U.L. Listed liquidtight.
CSA Certified watertight.
U.L. File No. E-23018
CSA File No. 2884
†

®
®

Liquidtight Flexible Metal/MS Connectors
Internal Thread
Cat.
No.

T&B Liquidtight flexible metal and Liquidtight
flexible nonmetallic fittings with internal
threads to accept AN-MS connector shells.
Material: Steel

Trade
Size

AN-MS Conn.
Shell Size

Dimensions (in.)
Thread Size

A

B

LTA03810

c"

10SL, 12, 12Se" – 24 UNEF-2B

1q

1

LTA05014
LTA05016
LTA05018

d"
d"
d"

14, 14Sf" – 20 UNEF-2B
16, 16Sg" – 20 UNEF-2B
18 1" – 20 UNEF-2B

1j
1j
1j

1b
1b
1b

LTA07520

f"

20, 221i" – 18 UNEF-2B

1k

1d

20, 221i" – 18 UNEF-2B
25, 281k" – 18 UNEF-2B

1f
1f

1z
1z

LTA10020
LTA10024

1"
1"

U.L. File No. E 23018
CSA File No. 2884

A130

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 131

A
T&B ® Fittings

Liquidtight Flexible Metal Conduit Fittings
NPT/MS Connector Adapters

A

B
Fig. 1

B

A

Fig. 2

Cat.
No.

N.P.T.
Thread

AN-MS
Connector
Shell Size

Thread
Size

Std.
Pkg.

A

Fig.

B

MSA05014
MSA05016
MSA05018

d"
d"
d"

14, 14S
16, 16S
18

f" – 20 UNEF-2B
g" – 20 UNEF-2B
1" – 20 UNEF-2B

10
10
10

1.000
1.000
1.125

1
2
3

1.175
1.175
1.175

MSA07516
MSA07518
MSA07520

f"
f"
f"

16, 16S
18
20, 22

g" – 20 UNEF-2B
1" – 20 UNEF-2B
1i" – 18 UNEF-2B

10
10
10

1.250
1.250
1.375

1
1
3

1.356
1.300
1.300

MSA10020
MSA10024
MSA10032
MSA10036

1"
1"
1"
1"

20, 22
24, 28
32
36

1i" – 18 UNEF-2B
1k" – 18 UNEF-2B
1f" – 18 UNS-2B
2" – 18 UNS-2B

10
10
10
10

1.500
1.625
2.000
2.250

1
3
3
3

1.431
1.313
1.576
1.738

Dimensions (in.)

All items shown on this page are suitable for use in hazardous location where general purpose equipment is specifically permitted by the
NEC; Class I Div. 2; Class II, Div. 1 & 2; Class III, Div. 1 & 2, NEC 501-4(b); 502-4(a)(b); 503-3(a)(b).

A

B
Fig. 3

Mechanical adapter with internal threads to
mate with NPT threaded fittings and MS type
connectors.
Material: aluminum

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A131

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 132

T&B ® Fittings

A
XTRAFLEX® System – Conduit, Tubing, Fittings for Nonmetallic Liquidtight Conduit
The BULLET® nonmetallic liquidtight fitting –
easy to use, built to take it.

• Clamping fingers. Outside surface has friction
reducing ridges; inner surface teeth bite into
conduit or tubing to enhance clamping and
sealing action.
• Fitting ferrule is designed to accept variations
in conduit sizes and field conduit cuts.
• Ferrule profile is smooth, reducing friction to
assure a tight conduit-to-fitting seal.
• Friction reducing ridges and teeth provide a
true double seal and high pullout resistance.
• Elongated gland nut provides additional strain
relief for 90° pull and easy hand grip.
• Rugged low-profile nonmetallic body and
gland construction provides space savings.
• Captivated sealing “O” ring features predetermined compression to provide a reliable seal
at enclosure.
• Steel locknut firmly secures fitting to box or
enclosure.

This engineering breakthrough meets
the demand for a tough, reusable, nonmetallic liquidtight fitting for use with
XTRAFLEX® Type B conduit or flexible
tubing.
The BULLET® nonmetallic fitting provides a reliable liquidtight seal that
combines high pullout resistance and
ease of installation.
Engineered to meet your needs.
The BULLET® nonmetallic fitting meets
your performance requirements when
terminating Type B liquidtight nonmetallic conduit or flexible nonmetallic tubing
to a box or enclosure with knockout
opening or threaded hub. Fittings meet
the watertight requirements for NEMA
type 4 and type 6 enclosures and conform to UL514B, and CSA No. 22.2
#227.2 specifications.
Ease of installation.
Installations can be performed quickly
and easily because BULLET® liquidtight fittings can be installed without

disassembly. BULLET® nonmetallic fittings are resistant to numerous caustics and solvents.
And the BULLET® fitting is economical
because it can be used over and over
again without sacrificing the quality of
the original seal. When used with the
XTRAFLEX® raceway system you can
meet most machine or industrial
requirements where liquidtight protection is needed.
Corrosion resistant. Built to take it.
The BULLET® liquidtight fitting is manufactured from weather resistant thermoplastic materials, and is suitable for
indoor or outdoor corrosive environments.
The BULLET® fitting is resistant to
detergents, cleaners, oils, sanitizers,
paints, cutting fluids and wiring pulling
compounds–just about any liquid usually found in industrial, plant or marine
environments. It also surpasses industry standards for cold impact and simulated hammer blows.
®
®

C

Plastic Bullet® Liquidtight Fittings for T&B LTC Nonmetallic
Liquidtight Conduit Type B and T&B EFC Flexible Tubing

B*

A

E
THREAD
D
FIGURE 1
(STRAIGHT)

F*
C

B*

A

E
THREAD
D
FIGURE 2
(45 DEGREE)

F*

C

B*

E
THREAD

A
D
FIGURE 3
(90 DEGREE)

A132

Trade A ±.015
Size
(.040)
(in) (in.) (mm)

*B ±.035 (0.90)
(in.) (mm)

C ±.015 (0.40)
Min.
Across
Throat
Corners
Dia. D
(in.) (mm)
(in.) (mm)

E
Thread
NPT
(in.)

F*
(in.) (mm)
Approx.

Cat.
No.

Fig.

LT38P
LT438P
LT938P

1
2
3

c

.570
(14.48)

1.595 (40.51)
2.012 (51.10)
1.380 (35.05)

1.354
(34.39)

.417
(10.59)

d-14

–
1.534 (38.95)
1.880 (47.75)

LT50P
LT450P
LT950P

1
2
3

d

.570
(14.48)

1.636 (41.55)
2.092 (53.14)
1.489 (37.82)

1.448
(36.78)

.550
(13.97)

d-14

–
1.590 (40.39)
1.986 (50.44)

LT75P
LT475P
LT975P

1
2
3

f

.582
(14.78)

1.757 (44.63)
2.452 (62.28)
1.790 (45.47)

1.740
(44.20)

.740
(18.80)

f-14

–
1.821 (46.25)
2.212 (56. )

LT100P
LT4100P
LT9100P

1
2
3

1

.726
(18.44)

1.923 (48.84)
2.684 (68.17)
2.104 (53.44)

2.068
(52.53)

.940
(23.88)

1-11d

–
2.034 (51.66)
2.508 (63.70)

LT125P
LT4125P
LT9125P

1
2
3

1b

.750
(19.05)

2.164 (54.97)
3.264 (82.91)
2.564 (65.13)

2.494
(63.35)

1.257
(31.93)

1b-11d

–
2.385 (60.58)
2.856 (72.54)

LT150P
LT4150P
LT9150P

1
2
3

1d

.767
(19.48)

2.353 (59.77)
3.605 (91.57)
2.854 (72.49)

2.784
(70.71)

1.453
(36.91)

1d-11d

–
2.604 (66.14)
3.144 (79.86)

LT200P
LT4200P
LT9200P

1
2
3

2

.794
(20.17)

2.605 (66.17)
4.210 (106.93)
3.432 (87.17)

3.362
(85.39)

1.883
(47.83)

2-8

–
3.050 (77.47)
3.675 (93.34)

* After Assembly
U.L. File No. E-23018
CSA File No. 52391

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 133

A
®

Specification Sheet – Bullet ® Liquidtight Fittings or Liquidtight
Flexible Nonmetallic Conduit and Tubing
Application

Box or
Enclosure
Wall

Conduit
or Tubing

A series of non-metallic connectors
designed to provide a liquidtight seal
when terminating liquidtight non-metallic conduit (U.L. Type B) or liquidtight
non-metallic tubing to a box or enclosure with knockout opening or a
threaded hub.
Plastic Bullet® Liquidtight Fittings Feature
• Connector assembles to conduit
without disassembly and is designed
to be installed with a positive installation criteria (gland bottoms on body
shoulder).
• Rugged low profile non-metallic body
and gland construction (1); the connector is equipped with a steel locknut
to firmly secure connector to box or an
enclosure and a sealing “O” ring.
• Captivated sealing “O” ring (2) with
predetermined compression for a reliable seal at enclosure.
• Connector ferrule designed to accept
variations in conduit inside diameter
and is tolerant of field conduit cuts (3).
• The profile of ferrule is designed to
reduce friction between conduit I.D.
and ferrule (4) allowing conduit to
seat properly for an effective seal.
• Outer surface of the clamping fingers
provided with friction reducing ridges
(5) for ease of installation; the inner
surface is designed with conduit biting teeth to enhance clamping and
sealing action (6).
• Performance of connectors tested to
simulate adverse installation conditions.

• Provides a double sealing action (7).
• Elongated gland nut profile (8) designed to provide additional strain relief
for 90° pull and an easy hand grip.
• Performance of connector unaffected
by exposure to detergents, cleaners,
and sanitizers commonly encountered in food processing plants and
typical industrial environment; also
unaffected by cutting fluids, wiring
pulling compounds and Marine environment. The connector meets industry standards for cold impact and
simulated hammer blow.
Standard Material/Finish
• Body Gland – weather stabilized thermoplastic (black).
• “O” Ring – nitrile (blue).
• Locknut – Steel/electro zinc plated.
• Material temperature rating – thermoplastic -40°C to 105°C.
• Material Flammability Rating:
U.L. 94-V2.
Listed/Certified by:
U.L. (File# E23018);
CSA (File# LR52391)
Conforms to:
• CSA 22.2 #227.2 & CSA 22.2 #227.3
• ANSI/U.L.514B-1988
• Watertight requirements of NEMA
Type 4 and NEMA Type 6 enclosures.
• Federal Standard H28 (NPT threads).
• Suitable for hazardous locations –
Class I Div. 2; Class II Div. 1 & 2;
Groups E,F, & G; Class III per N.E.C.;
Article 501-4, 502-4 and 503-3.

Suggested Specification:
Where liquidtight flexible nonmetallic conduit (U.L. Type B) or liquidtight flexible nonmetallic
tubing is terminated to a box or enclosure, the nonmetallic connectors used shall be able to
be installed without disassembly and provide a positive installation criteria. In the installed
condition, the connector must provide a seal meeting watertight requirements of NEMA Type
4 and Type 6 enclosures. The performance of connectors shall be unaffected by exposure to
detergents, sanitizers, cutting fluids, wire pulling compounds and oil base industrial paints.
The connector must also be capable of withstanding Marine environment and cold impact
simulating a hammer blow. Installed connectors shall be of the elongated gland type as
manufactured by Thomas & Betts LT38P series.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A133

T&B ® Fittings

XTRAFLEX System – Conduit, Tubing, Fittings for Nonmetallic Liquidtight Conduit

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 134

T&B ® Fittings

A
XTRAFLEX® System – Conduit, Tubing, Fittings for Nonmetallic Liquidtight Conduit
Table 1 – Behavior of EMS20-1B.1 IN: Aqueous Solutions of Inorganic Salts at Room Temperature
Salt Solutions
10% Ammonium Chloride
10% Aluminum Chloride
10% Sodium Hypochlorite (0.1% Cl2)
10% Calcium Chloride
10% Chrome Alum
10% Ferric Chloride
5% Potassuim Dichromate
10% Potassium Nitrate
1% Potassium Permanganate
10% Copper Sulfate
10% Magnesium Chloride
10% Magnanese Sulfate
10% Sodium Sulfate
10% Sodium Bisulfite
5% Mercuric Chloride
10% Zinc Chloride

Visual Change

Ratings*

Unchanged
Unchanged
White coating after 18 days
Unchanged
Unchanged
Unchanged yellowing
Unchanged yellowing
Unchanged
Decomposed
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Swelled
Unchanged

F
F
G
F
G
P
P
G
NR
G
G
G
G
G
P
F

* These abbreviations are used for the ratings:
E- Excellent
P- Poor
G- Good
NR- Not Recommended
F- Fair
S- Solvent

Table 2 – Behavior of EMS20-1B.1 IN: Acids,
Bases, Halogens, etc.
Reagent
Sulfuric Acid (Conc)
Sulfuric Acid (Dilute)
Hydrochloric Acid (Conc)
Hydrochloric Acid (Dilute)
Hydrochloric Acid (20-40%)
Phosphoric Acid (Conc)
Nitric Acid (Conc)
Acetic Acid (Conc)
Acetic Acid (Conc)
Acetic Acid (Dilute)
Formic Acid (Conc)
Formic Acid (Dilute)
Chlorine
Bromine
Phenol
O-Chlorophenol
m-Chlorophenol
p-Chlorophenol
Cresol
Dimethylformamide
gamma-Butyrolactone
Xylenols
Sodium Hydroxide (1%)
Sodium Hydroxide (5%)
Sodium Hydroxide (5%)
Sodium Hydroxide (10%)
Sodium Hydroxide (10%)
Potassium Hydroxide (5%)
Potassium Hydroxide (5%)
Potassium Hydroxide (10%)
Potassium Hydroxide (10%)
Hydrogen Peroxide (0.5%)
Hydrogen Peroxide (1%)
Hydrogen Peroxide (3%)
Hydrogen Peroxide (10%)
Hydrogen Peroxide (30%)

Temp °F

Visual Change

Ratings*

75
75
75
75
73
75
75
75
200
75
75
75
–
–
75
75
75
75
75
75
75
75
73
73
158
73
158
73
158
73
158
73
73
73
73
73

Dissolves
Partially dissolves
Dissolves
Partially dissolves
Etched after 1 sec.
Dissolves
Dissolves
Partially Dissolves
Dissolves
Etched
Dissolves
Partially Dissolves
Strong Attack
Strong Attack
Dissolves
Dissolves
Dissolves
Dissolves
Dissolves
Strong Attack
Strong Attack
Dissolves
Unchanged
Minimal effect
Minimal effect
Minimal effect
Some “crazing” after 30 days
Minimal effect
Minimal effect
Minimal effect
Some “crazing” after 30 days
Unchanged
Brittle after 54 days
Brittle after 54 days
Degrades
Degrades

S, NR
P, NR
S, NR
P, NR
P
S, NR
S, NR
P, NR
S, NR
F, NR
S, NR
P, NR
NR
NR
S, NR
S, NR
S, NR
S, NR
S, NR
NR
NR
S, NR
E
E
E
E
P
E
E
E
P
G
NR
NR
NR
NR

* These abbreviations are used for the ratings:
E- Excellent
P- Poor
G- Good
NR- Not Recommended
F- Fair
S- Solvent

A134

Table 3 – Behavior of EMS20-1B.1 IN:
Organic Solvents at Room Temperature
Reagent
Benzyl Alcohol
Butyl Alcohol
Ethyl Alcohol
Isopropyl Alcohol
Methyl Alcohol
Butyl Acetate
Ethyl Acetate
Methyl Acetate
Amyl Acetate
Ether (Diethyl)
Tetrahydrofuran
Acetone
Benzaldyhyde
Cyclohexanone
Dichlorethylene
Trichlorethylene
Perchlorethylene
Dichlormethane
Chloroform
Carbon Tetrachloride
Carbon Disulfide
Pyridine
Benzene
Monochlorbenzene
Toluene
Xylene
Kerosene
Turpentine
Tetralin
Decalin
Gasoline
Petroleum
Mineral Oil
Resorcinol

Visual Change

Ratings*

Coarse surface after 2 days
Temporary loss of stiffness
Temporary loss of stiffness
Temporary loss of stiffness
Temporary loss of stiffness
Temporary loss of stiffness
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Temporary loss of stiffness
Temporary loss of stiffness
Unchanged
Temporary loss of stiffness
Temporary loss of stiffness
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Unchanged
Dissolves

NR
G
G
G
G
G
E
E
E
E
E
E
E
E
E
G
G
E
G
G
E
E
E
E
E
E
E
E
E
E
E
E
E
NR

* These abbreviations are used for the ratings:
E- Excellent
P- Poor
G- Good
NR- Not Recommended
F- Fair
S- Solvent

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 135

A
®

®
®

Metallic Bullet® Liquidtight Connectors for T&B LTC Nonmetallic
Liquidtight Conduit Type B and T&B EFC Flexible Tubing

Figure 1

Figure 2

Trade
Size
(in.)

A ±.030
(.80)
(in.) (mm)

*B ±.060
(1.50)
(in.) (mm)

C ±.045
(1.15)
(in.) (mm)

1
2
3

c

1.156
(29.4)

1.500 (38.1)
1.962 (49.8)
1.312 (33.3)

0.562 (14.3)
0.562 (14.3)
0.625 (15.9)

LT50M
LT450M
LT950M

1
2
3

d

1.562 (39.7)
1.875 (47.6)
1.437 (36.5)

0.562 (14.3)
0.562 (14.3)
0.625 (15.9)

LT75M
LT475M
LT975M

1
2
3

f

1.625 (41.2)
2.125 (54.0)
1.750 (44.4)

0.625 (15.9)
0.562 (14.3)
0.625 (15.9)

LT100M
LT4100M
LT9100M

1
2
3

1

2.062 (52.4)
2.250 (57.1)
1.937 (49.2)

0.750 (19.0)
0.812 (20.6)
0.812 (20.6)

LT125M
LT4125M
LT9125M

1
2
3

1b

2.500 (63.5)
2.750 (69.8)
2.500 (63.5)

0.812 (20.6)
0.812 (20.6)
0.812 (20.6)

LT150M
LT4150M
LT9150M

1
2
3

1d

2.687 (68.2)
2.750 (69.8)
2.812 (71.4)

0.812 (20.6)
0.812 (20.6)
0.812 (20.6)

LT200M
LT4200M
LT9200M

1
2
3

2

3.062 (77.8)
3.875 (98.4)
3.500 (88.9)

0.812 (20.6)
0.875 (22.2)
0.875 (22.2)

Cat.
No.

Fig.

LT38M
LT438M
LT938M

1.375
(34.9)
1.656
(42.1)
1.875
(47.6)
2.375
(60.3)
2.750
(69.8)
3.468
(88.1)

D
(in.) (mm)

Thread
NPT
(in.)

–
d-14
1.375 (34.9)
–
d-14
1.562 (39.7)
–
f-14
1.750 (44.4)
–
1-11d
2.187 (55.5)
–
1b-11d
2.750 (69.8)
–
1d-11d
2.937 (74.6)
–
2-11d
3.437 (87.3)

* After Assembly
U.L. File No. E-23018
CSA File No. 52391

Suggested Specification:

NPT Thread
Figure 3

Where liquidtight flexible nonmetallic conduit (U.L. Type B) or liquidtight flexible nonmetallic
tubing is terminated to a box or enclosure, the metallic connectors used shall be able to be
installed without disassembly and provide a positive installation criteria. In the installed condition, the connector must provide a seal, meeting watertight requirements of NEMA Type 4 and
Type 6 enclosures with conduit and NEMA Type 4 enclosures with tubing. Installed connectors shall be as manufactured by Thomas & Betts LT38M series.
Material: Body/Gland–Steel/MI
Insert–Nylon

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A135

T&B ® Fittings

XTRAFLEX System – Conduit, Tubing, Fittings for Nonmetallic Liquidtight Conduit

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 136

T&B ® Fittings

A
XTRAFLEX® System – Conduit, Tubing, Fittings for Nonmetallic Liquidtight Conduit
Material – PVC
When you have a conduit application in a liquidtight environment, it's time to load up
the T&B Bullet®. Thomas & Betts introduces the ISO Metric Bullet® liquidtight fittings for
use with the c", d", and f" Xtraflex® EFC and LTC nonmetallic
liquidtight conduit series.
The T&B Bullet® liquidtight fitting and EFC non-metallic
conduit are suited for OEM applications as in the
machine tool industry where environments include
continuous motion, vibration, and exposure to moisture, oil, dirt and dust.
The T&B Bullet® liquidtight fitting and LTC nonmetallic conduit are also suitable for construction
applications where ISO metric threading and liquidtight systems are installed.
The Xtraflex® system offers a lightweight, liquidtight
flexible conduit solution for industrial applications. The
Xtraflex® system allows fast, easy installation and high performance in demanding industrial applications.

ISO Metric Bullet® Liquidtight Fitting
Cat.
No.
LT38M-ISO20
LT50M-ISO20
LT75M-ISO25
LT438M-ISO20
LT450M-ISO20
LT475M-ISO25
LT938M-ISO20
LT950M-ISO20
LT975M-ISO25

Angle
of Fitting

Conduit
Size

Knockout
Size

Unit
Package

Standard
Package

UPC
Number

Straight
Straight
Straight
45°
45°
45°
90°
90°
90°

c"
d"
f"
c"
d"
f"
c"
d"
f"

d"
d"
f"
d"
d"
f"
d"
d"
f"

25
25
25
25
25
10
25
25
10

100
100
50
50
50
50
50
50
50

786210-62281
786210-62282
786210-62283
786210-62284
786210-62285
786210-62286
786210-62288
786210-62289
786210-62290

*Meets watertight requirements of NEMA Type 4 enclosure or IP 56 rating with LTC conduit or EFC tubing with installed T&B Bullet liquidtight fittings. Connector Locknut not included.

ISO Metric Bullet® Liquidtight Fitting Non-Metallic
Cat.
No.
LT38P-ISO20
LT50P-ISO20
LT75P-ISO25
LT938P-ISO20
LT950P-ISO20
LT975M-ISO25

Angle
of Fitting

Conduit
Size

Knockout
Size

Unit
Package

Standard
Package

UPC
Number

Straight
Straight
Straight
90°
90°
90°

c"
d"
f"
c"
d"
f"

d"
d"
f"
d"
d"
f"

25
25
25
25
25
10

100
100
50
50
50
50

786210-66444
786210-66613
786210-66443
786210-66612
786210-66640
786210-66611

*Testing: UL and CSA listed; NEMA 4, 6, 6P; IP 67 when used with LTC conduit or EFC tubing with installed T&B Bullet liquidtight fitting.

A136

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 137

A
®

T&B ® Fittings

XTRAFLEX System – Conduit, Tubing, Fittings for Nonmetallic Liquidtight Conduit
Material – PVC
®
®

Corrugated Flexible Nonmetallic Tubing

OEM Grade U.L. Recognized
• Material – PVC.
• Black color standard.
• Maximum flexibility in tight applications.
• Extremely fast installation.
• Liquidtight with specified fittings.
• Good tensile strength provides excellent pullout
protection.
• Smooth inner diameter allows easy wire pulling.
• Broad operating temperature range – 18°C to
+60°C (-2°F to +140°F).
• Flammability Rating VW-1 (Vertical Wire) UL224.
Recommended industrial applications
• Protection of fiber optic cable.
• Installation of instrumentation and control
cable.
• Indoor/outdoor lighting.
• Packaging equipment.
• Marine and shipboard wiring.
• Flexing – component wiring protection on
robots, graphic arts equipment, etc.

I.D. (in.)

O.D. (in.)

Cat. No.

Conduit
Size

min.

max.

min.

max.

EFC025*
EFC038
EFC050
EFC075
EFC100
EFC125
EFC150
EFC200

b"
c"
d"
f"
1"
1b"
1d"
2"

.390
.484
.622
.820
1.041
1.380
1.575
2.020

.405
.504
.642
.840
1.066
1.410
1.600
2.045

.560
.690
.820
1.030
1.290
1.630
1.865
2.340

.575
.710
.840
1.050
1.315
1.660
1.900
2.375

Available Colors

* Not CSA Certified.
Underwriters Recognized
U.L. File No. 96548
CSA File No. 067241
See technical data next page.
Use with Bullet® Liquidtight Fittings.

Cat. No.
LTC –

Color of
Conduit

w/o suffix
-1
-2

Black
Orange
Blue

O.D

I.D.

®
®

Commercial Grade U.L./CSA Listed
• Gray color standard
• 80°C temperature rated
• UV resistant
• Material – PVC

Commercial Grade Type B Nonmetallic Liquidtight Conduit
I.D. (in.)

O.D. (in.)

Cat.
No.

Size

min.

max.

min.

max.

LTC038GY
LTC050GY
LTC075GY
LTC100GY
LTC125GY
LTC150GY
LTC200GY

c"
d"
f"
1"
1b"
1d"
2"

.484
.622
.820
1.041
1.380
1.575
2.020

.504
.642
.840
1.066
1.410
1.600
2.045

.690
.820
1.030
1.290
1.630
1.865
2.340

.710
.840
1.050
1.315
1.660
1.900
2.375

U.L. Listed, U.L. File No. 95745
CSA Certified, CSA File No. LL 80349
See technical tables on next page.

I.D.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

O.D.

A137

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 138

A
T&B ® Fittings

®

XTRAFLEX System – Conduit, Tubing, Fittings for Nonmetallic Liquidtight Conduit
Material – PVC
®
®

Smooth Liquidtight Nonmetallic Conduit Type B

Industrial Grade U.L./CSA Listed
• Material – PVC.
• Liquidtight nonmetallic conduit Type B.
• Black color standard.
• Fast installation – even in tight, cramped
spaces.
• Smooth inner diameter allows easy wire
pulling.
• Smooth outer jacket – uses material approved
for outdoor use, is sunlight resistant and oil
resistant.
• Tested to CSA and U.L. requirements.
• Lightweight and liquidtight.
• Temperature range of -18°C to +105°C
(-2°F to +221°F).
• Flammability Rating – UL1660.
• Marked at one-foot intervals for fast, easy
measuring and cutting.

I.D. (in.)

Cat. No.

Conduit
Size

min.

LTC038
LTC050
LTC075
LTC100
LTC125
LTC150
LTC200

c"
d"
f"
1"
1b"
1d"
2"

.484
.622
.820
1.041
1.380
1.575
2.020

O.D. (in.)
max.
.504
.642
.840
1.066
1.410
1.600
2.045

Rated at 600V
XTRAFLEX® Type B suitable for use in hazardous location (for LTC
Series only) where general purpose equipment is specifically permitted Cat. No.
LTC –
by the NEC; Class I Div. 2; Class II, Div. 1 & 2; Class III, Div. 1 & 2,
NEC 501-4(b); 502-4(a)(b); 503-3(a)(b).
w/o
suffix
U.L. Listed, U.L. File No. E95745
-1
CSA Certified, CSA File No. LL80349
-2
See technical data below.
®
Use with Bullet Liquidtight Fittings.

Recommended industrial applications
• Machine tools.
• Motor hookups.
• Food processing equipment.
• Extensions from wireways.
• Sensor and microswitch wiring found in
control consoles.

I.D.

min.

max.

.690
.820
1.030
1.290
1.630
1.865
2.340

.710
.840
1.050
1.315
1.660
1.900
2.375

Available Colors
Color of
Conduit

Color of
Marking

Black
Orange
Blue

Orange
Black
Black

O.D.

XTRAFLEX ® Conduit and Tubing Technical Data*
LTFNMC = Liquidtight flexible nonmetallic conduit.
LTFNMT = Liquidtight flexible nonmetallic tubing.
Xtraflex®
Conduit &
Tubing

Size
Range

U.L. Temp
Rating

CSA Temp
Rating

Voltage
Rating

U.L. Oil
Resistant

U.L.
Outdoor

U.L. Direct
Burial

Black
Black

c"-2"

75°C-18 C

600V

Yes

Yes

Yes

UL Type B
LTFNMC

Orange,
Blue

d"-1"

–

600V

Yes

No

Yes

LTC038GY
Series

UL Type B
LTFNMC

Grey

c"-2"

–

600V

Yes

Yes

Yes

EFC025 Series**
EFC025-1, -2**
Series

LTFNMT
LTFNMT

Black
Orange,
Blue

b"-2"
d"-1"

105°C Dry
60°C Wet
70°C Oil
105°C Dry
60°C Wet
70°C Oil
80°C Dry
60°C Wet
70°C Oil
105°C
105°C

75°C-18 C
–

300V
300V

Yes
Yes

Yes
No

No
No

Style

Color

LTC038 Series

UL Type B
LTFNMC

LTC038-1, -2
Series

* For a complete test report, contact Customer Service.
** U.L. Component Recognized

A138

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 139

A
®

T&B ® Fittings

XTRAFLEX System – Conduit, Tubing, Fittings for Nonmetallic Liquidtight Conduit
Material – PVC
XTRAFLEX ® Nonmetallic Conduit Type B and Flexible Tubing
A = Satisfactory
Chemical
Acetate Solvents . . . . . . . . . . . . . . . . . . . . . . . . C
Acetic Acid (10%). . . . . . . . . . . . . . . . . . . . . . . A
Acetic Acid (Glacial) . . . . . . . . . . . . . . . . . . . . . B
Acetone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Acrylonitrile . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Adipic Acid . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Alcohol Butyl . . . . . . . . . . . . . . . . . . . . . . . . . . A
Alcohol Ethyl . . . . . . . . . . . . . . . . . . . . . . . . . . A
Alcohol Isopropyl . . . . . . . . . . . . . . . . . . . . . . . A
Alcohol Methyl . . . . . . . . . . . . . . . . . . . . . . . . . A
Aluminum Acetate. . . . . . . . . . . . . . . . . . . . . . . A
Aluminum Chloride . . . . . . . . . . . . . . . . . . . . . A
Aluminum Hydroxide . . . . . . . . . . . . . . . . . . . . A
Aluminum Sulfate . . . . . . . . . . . . . . . . . . . . . . . A
Aliyl Chloride . . . . . . . . . . . . . . . . . . . . . . . . . . C
Ammonia (0.88S.G.Aqueous) . . . . . . . . . . . . . . A
Ammonia (Dry Gas) . . . . . . . . . . . . . . . . . . . . . A
Ammonia (Liquid) . . . . . . . . . . . . . . . . . . . . . . C
Ammonium Chloride . . . . . . . . . . . . . . . . . . . . A
Ammonium Hydroxide . . . . . . . . . . . . . . . . . . . A
Animal Oils . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Amyl Acetate. . . . . . . . . . . . . . . . . . . . . . . . . . . C
Aniline Oils . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
Aromatic Hydrocarbons . . . . . . . . . . . . . . . . . . C
Asphalt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
ASTM Fuel A . . . . . . . . . . . . . . . . . . . . . . . . . . B
ASTM Fuel B . . . . . . . . . . . . . . . . . . . . . . . . . . C
ASTM #1 Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . A
ASTM #3 Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . B
Barium Chloride . . . . . . . . . . . . . . . . . . . . . . . . A
Barium Hydroxide . . . . . . . . . . . . . . . . . . . . . . . A
Barium Sulfide . . . . . . . . . . . . . . . . . . . . . . . . . A
Benzene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Benzine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
Bordeaux Mixture . . . . . . . . . . . . . . . . . . . . . . . A
Borax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Boric Acid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Brine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Bromine Traces. . . . . . . . . . . . . . . . . . . . . . . . . C
Butyl Acetate. . . . . . . . . . . . . . . . . . . . . . . . . . . C
Calcium Hydroxide . . . . . . . . . . . . . . . . . . . . . . A
Calcium Hypochlorite . . . . . . . . . . . . . . . . . . . . A
Carbonic Acid . . . . . . . . . . . . . . . . . . . . . . . . . . B
Carbon Dioxide. . . . . . . . . . . . . . . . . . . . . . . . . A
Carbon Disulphite . . . . . . . . . . . . . . . . . . . . . . C
Carbon Monoxide . . . . . . . . . . . . . . . . . . . . . . . A
Carbon Tetrachloride . . . . . . . . . . . . . . . . . . . . C
Casein . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Chlorine (Dry). . . . . . . . . . . . . . . . . . . . . . . . . . A
Chlorine (Wet Gas) . . . . . . . . . . . . . . . . . . . . . . B
Chlorine (Water) . . . . . . . . . . . . . . . . . . . . . . . . C
Chlorobenzene . . . . . . . . . . . . . . . . . . . . . . . . . C
Chlorinated Hydrocarbons . . . . . . . . . . . . . . . . C
Chloroform . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Chromic Acid . . . . . . . . . . . . . . . . . . . . . . . . . . A
Citric Acid. . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Coal Tar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Copper Chloride . . . . . . . . . . . . . . . . . . . . . . . . A
Copper Nitrate . . . . . . . . . . . . . . . . . . . . . . . . . A
Copper Sulphate . . . . . . . . . . . . . . . . . . . . . . . . A

B = Be Expected to Change
Chemical
Cottonseed Oil . . . . . . . . . . . . . . . . . . . . . . . . . B
Creosote. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Cresol. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Cresylic Acid . . . . . . . . . . . . . . . . . . . . . . . . . . C
Cyclohexane . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Cyclohexanone. . . . . . . . . . . . . . . . . . . . . . . . . C
DDT Weed Killer . . . . . . . . . . . . . . . . . . . . . . . . A
Detergent Synthetic. . . . . . . . . . . . . . . . . . . . . . A
Developers Photographic . . . . . . . . . . . . . . . . . A
Dextrin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Dextrose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Dibutyle Phthalate . . . . . . . . . . . . . . . . . . . . . . C
Dichlorobenzene. . . . . . . . . . . . . . . . . . . . . . . . C
Diesel Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
Diethylene Glycol . . . . . . . . . . . . . . . . . . . . . . . A
Diethyl Ether. . . . . . . . . . . . . . . . . . . . . . . . . . . C
Di-isodecyl Phthalate . . . . . . . . . . . . . . . . . . . . C
Dioctyle Phthalate. . . . . . . . . . . . . . . . . . . . . . . C
Emulsifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Emulsions Photographic. . . . . . . . . . . . . . . . . . A
Ethyl Acetate. . . . . . . . . . . . . . . . . . . . . . . . . . . C
Ethylene Dichloride . . . . . . . . . . . . . . . . . . . . . C
Ethylene Glycol. . . . . . . . . . . . . . . . . . . . . . . . . A
Fatty Acid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Ferric Chloride . . . . . . . . . . . . . . . . . . . . . . . . . A
Ferric Sulphate . . . . . . . . . . . . . . . . . . . . . . . . . A
Ferrous Chloride. . . . . . . . . . . . . . . . . . . . . . . . A
Ferrous Sulphate . . . . . . . . . . . . . . . . . . . . . . . A
Fixing Solution Photographic . . . . . . . . . . . . . . A
Fluorine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Formaldehyde (40%) . . . . . . . . . . . . . . . . . . . . C
Formic Acid (40%) . . . . . . . . . . . . . . . . . . . . . . A
Formic Acid (50%) . . . . . . . . . . . . . . . . . . . . . . B
Formic Acid (100%). . . . . . . . . . . . . . . . . . . . . C
Fuel Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
Glacial Acetic Acid . . . . . . . . . . . . . . . . . . . . . . B
Glucose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Glycerine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Grape Sugar . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Grease . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Heptane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
Hexane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
Hydrobromic Acid. . . . . . . . . . . . . . . . . . . . . . . A
Hydrochloric Acid (10%) . . . . . . . . . . . . . . . . . A
Hydrochloric Acid (40%) . . . . . . . . . . . . . . . . . A
Hydrofluoric Acid (10%). . . . . . . . . . . . . . . . . . A
Hydrofluoric Acid (40%). . . . . . . . . . . . . . . . . . B
Hydrofluoboric Acid . . . . . . . . . . . . . . . . . . . . . A
Hydrofluosilicic Acid . . . . . . . . . . . . . . . . . . . . A
Hydrogen Peroxide . . . . . . . . . . . . . . . . . . . . . . A
Hydrogen Sulphide. . . . . . . . . . . . . . . . . . . . . . A
Iso-octan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Isopropyl Acetate . . . . . . . . . . . . . . . . . . . . . . . C
Kerosene. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
Ketones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Lactic Acid (10%). . . . . . . . . . . . . . . . . . . . . . . A
Lactic Acid (100%). . . . . . . . . . . . . . . . . . . . . . C
Lacquer Solvents . . . . . . . . . . . . . . . . . . . . . . . B
Linseed Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . A

C = Not Recommended
Chemical
Lubricating Oils . . . . . . . . . . . . . . . . . . . . . . . . . A
Magnesium Chloride . . . . . . . . . . . . . . . . . . . . . A
Magnesium Hydroxide. . . . . . . . . . . . . . . . . . . . A
Magnesium Sulphate. . . . . . . . . . . . . . . . . . . . . A
Malic Acid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Methyl Acetate. . . . . . . . . . . . . . . . . . . . . . . . . . C
Methyl Bromide. . . . . . . . . . . . . . . . . . . . . . . . . C
Methyl Ethyl Ketone. . . . . . . . . . . . . . . . . . . . . . C
Methylene Chloride . . . . . . . . . . . . . . . . . . . . . . C
Mineral Oils. . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Monochlorobenzene . . . . . . . . . . . . . . . . . . . . . C
Naphtha . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
Naphthalene . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Nitric Acid (10%). . . . . . . . . . . . . . . . . . . . . . . . A
Nitric Acid (40%). . . . . . . . . . . . . . . . . . . . . . . . A
Nitric Acid (70%) . . . . . . . . . . . . . . . . . . . . . . . C
Nitrobenzene . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Nitrogen Fertilizers . . . . . . . . . . . . . . . . . . . . . . A
Oleic Acid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Oxalic Acid . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Palmitic Acid . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Paraffin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Pentane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
Perchloroethylene . . . . . . . . . . . . . . . . . . . . . . . C
Phenol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
Phosphoric Acid . . . . . . . . . . . . . . . . . . . . . . . . A
Pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Potassium Hydroxide. . . . . . . . . . . . . . . . . . . . . A
Propane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Sea Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Sodium Hydroxide (10%) . . . . . . . . . . . . . . . . . A
Sodium Hydroxide (50%) . . . . . . . . . . . . . . . . . A
Sodium Cyanide . . . . . . . . . . . . . . . . . . . . . . . . A
Soybean Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Stearic Acid . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Styrene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Sulphur Dioxide (Dry) . . . . . . . . . . . . . . . . . . . . A
Sulphur Dioxide (Moist) . . . . . . . . . . . . . . . . . . B
Sulphur Dioxide (Liquid). . . . . . . . . . . . . . . . . . C
Sulphuric Acid (45%) . . . . . . . . . . . . . . . . . . . . A
Sulphuric Acid (60%) . . . . . . . . . . . . . . . . . . . . B
Sulphuric Acid (98%) . . . . . . . . . . . . . . . . . . . . C
Sulphurous Acid (30%). . . . . . . . . . . . . . . . . . . A
Tannic Acid . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Tartaric Acid. . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Tetrahydrofuran . . . . . . . . . . . . . . . . . . . . . . . . . C
Toluene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Trichlorethylene. . . . . . . . . . . . . . . . . . . . . . . . . C
Triethanolamine . . . . . . . . . . . . . . . . . . . . . . . . . A
Tricresyl Phosphate . . . . . . . . . . . . . . . . . . . . . . C
Turpentine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
Urea. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Vinegar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Vinyl Acetate . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Vinyl Chloride . . . . . . . . . . . . . . . . . . . . . . . . . . C
Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Xylene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Zinc Chloride. . . . . . . . . . . . . . . . . . . . . . . . . . . A
Zinc Sulphate. . . . . . . . . . . . . . . . . . . . . . . . . . . A

Note: These chemical resistance ratings are based upon information supplied by the raw material manufacturers. It is intended as a general guideline only. To determine specific suitability, samples should be
tested by user under actual conditions. Operating Condition: 70°F.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A139

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 140

T&B ® Fittings

A
Flexible Cords and Cable Fittings
Flexible Cord Connectors
The Ranger™ Series Cord Connector
Fittings
Our Ranger Liquidtight fittings are the
only connectors able to take a .250
inch cable range.
These unique connectors feature:
• Connectors which take twice the
cable range of ordinary strain relief
connectors.

A140

• Smaller overall size which makes it
easy to fit into tight spaces.
• Gland nut design that restricts cable
bending.
• Choice of aluminum, steel and nonmetallic materials.
• Straight, 45° and 90° designs.

Liquidtight Flexible Cord and Power
Cable Fittings

The advantages these fittings offer
include:

We also offer Liquidtight fittings
designed to handle the unique connection demands of flexible cords
and power cables applications, where
exceptional mechanical strain relief is
needed in addition to a dependable
seal against dust, oil, and other liquids.
The patented design of our flexible
cord and power cable fittings are ideal
for installations such as robot manufacturers, packaging equipment, machine
tool building and other industrial OEM
and MRO applications.

• Neoprene bushing to make liquidtight installations by applying pressure against the cable for the full
length of the bushing.
• CSA certified water tight, and U.L.
listed for liquid-tightness strain relief
and as an outlet bushing.
• Metal and plastic assemblies capable
of accepting a wide range of cords.
• Black Beauty™ non-metallic cord connector offers the convenience of toolfree installation, with a segmented
chuck for high mechanical pullout performance, and neo-prene bushings for
a secure, liquid-tight installation.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 141

A
Whatever the application. Whatever the size. Thomas & Betts
is your connection to tough, versatile cord and cable fittings.
Thomas & Betts offers a complete line of rugged, reliable cord and cable fittings. All fittings are produced to the highest standards, combining innovative
design and precision manufacturing methods to provide the products you need
for your specific applications. Combining proven performance, installation
advantages and availability of ranges, T&B is also your connection to lower
installed costs for the life of your cord and cable requirements.
Use this guide to help you specify the fitting you need for your cord and cable
requirements.
Cord and Cable Requirements
Cord and Cable Type

T&B Fitting

S, SO, SV, ST, STD, SJ,
SJO, SJT, SJTO, SVO

Ranger™ 2920NM# Series, 2920# Series
Liquidtight Strain Relief 2500# Series

TC

Tray Cable TC Series

JMC, MC

Star® Teck Extreme™ STE/STEX Series

S, SO, SV, ST, STD, SJ,
SJO, SJT, SJTO, SVO

Wire Mesh Grips WMG-PC Series
for Portable Cord

Considerations for Selection
• Selection of the proper device or fitting involves consideration of the type of
cable to be installed and the environment that will surround the cable
installation.
• A proper matching of the cable and its fitting is necessary to prevent
physical damage to the cable when installed.
Cord and Cable Descriptions
Type TC power and control tray cable is a factory assembly of two or more insulated conductors, with or without associated bare or covered grounding conductors
under a nonmetallic sheath, for installation in cable trays, in raceways, or where
supported by a messenger wire.
Type MC metal clad cable is a factory assembly of one or more insulated circuit conductors with or without optical-fiber members enclosed in a metallic
sheath of interlocking tape, or a smooth or corrugated tube.
Type SJ, tradename is Junior Hard Service Cord. The outer covering is
Thermoset and it is a pendant or portable cord used in damp locations for
hard usage.
Type SJO, tradename is Junior Hard Service Cord. The outer covering is
oil-resistant Thermoset.
Type SJT, tradename is Junior Hard Service Cord. The outer covering
is Thermoplastic.
Type SJTO, tradename is Junior Hard Service Cord. The outer covering is oil
resistant Thermoplastic.
Type SO, tradename is Hard Service Cord. The outer covering is oil-resistant
Thermoset and it is a pendant or portable cord used in damp locations for extra
hard usage.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A141

T&B ® Fittings

Flexible Cords and Cable Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 142

T&B ® Fittings

A
Flexible Cords and Cable Fittings
Liquidtight Flexible Cord and Cable Connectors
Application
• A liquidtight connector to connect
flexible cord or cable to an enclosure
and provide adequate strain relief
2920 Series

Features
• Liquidtight connection with enclosure
is assured by:
(A) Taper threaded hub on 2520
series for female hub application
(B) Using sealing ring series 5262
with 2520 series for knockout
application
(C) Captivated sealing ‘O’ ring on
2631 series
(D) Neoprene bushing makes liquidtight installation; applies pressure against cable the full length
of bushing
(E) Thermoplastic or stainless steel
retaining ring
(1) Will not abrade cord/cable
jacket
(2) Reduces installing torque
effort
• U.L. Listed liquidtight, strain relief
and as an outlet bushing; CSA certified watertight

2920AL Series

2516 Series

Retaining
Ring

(E)

Bushing
(D)

Gland, Body ..Steel/Malleable Iron/Zinc
Die Cast
Retaining Ring ..............Thermoplastic/
Stainless Steel
Bushing.................................Neoprene
‘O’ Ring .....................................Buna N
Standard Finish
Electro Zinc Plated & Chromate
Coated
Range
2520 Series, straight .........125" outside
diameter to 3.200"
outside diameter Cord or Cable
2200 Series, 45°................125" outside
diameter to 1.485"
outside diameter Cord or Cable
2267 Series, 90°................125" outside
diameter to 1.875"
outside diameter Cord or Cable
Cord/Cable Type.............S, SO, SV, ST,
STO, SJ, SJO, SJT,
SJTO, SVO & SVT
Listed/Certified by:
U.L....................(U.L. File No. E-13938)
CSA ...........................LR-589, LR-4484

Gland

Gland

Standard Material

Conforms to:

Retaining
Ring

(E)

Bushing

(D)

U.L. 514
CSA 22.2 No. 18
ANSI C33.84, NFPA 70-1978 (ANSI)

Body
Body

(C)

(A)

Sealing
Gasket

(B)

2520 Series

A142

Nipple

2631 Series

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 143

A
Suggested Specifications for Flexible Cord and Cable Fittings

2920 Series

2920NM Series

2920AL Series

• Flexible cord or cable and associated fittings shall be suitable for conditions of use and location and
approved for the purpose by a
nationally recognized testing laboratory, inspection agency or product
evaluation organization.
• Flexible cord or cable shall be so
connected to the device or fitting that
tension will not be transmitted to
joints or terminal screws. Sufficient
slack shall be provided to avoid
sharp flexing and straining. Cord or
cable shall be installed in such a
manner that liquid will tend to run off
the surface instead of draining
towards the fitting.

• Where flexible cord or cable exposed
to intermittent or constant moisture
and subjected to mechanical strain is
terminated into a threaded or threadless opening, terminating fittings
shall be of watertight strain relief type
such as Thomas & Betts series 2920,
2920AL, 2920NM, 2520, 2631 or
2672. Fittings shall be equipped with
a beveled moisture resistant/oil resistant synthetic rubber bushing.
• Where space is limited inside the
enclosure, a female hub type fitting
such as Thomas & Betts series 2631
shall be furnished. A captivated
resilient sealing ‘O’ ring shall be
included to positively protect against
damage from overtorquing.

2516 Series

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A143

T&B ® Fittings

Flexible Cords and Cable Fittings

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 144

Flexible Cords and Cable Fittings
The Ranger™ Series of Steel Liquidtight Cord Connectors
The Ranger Series Steel Liquidtight Connector takes twice the cable range of most
ordinary strain relief connectors. T&B’s Ranger Connectors allow you to reduce
your inventory and save time, with one connector that can do the work of two.
Application
• Provide means for passing a cord cable
(armored or unarmored) into an enclosure,
through a bulkhead or into a rigid conduit.
• Form a mechanical grip and water and/or oilresistant seal for cord and unarmored or jacketed armored round cables.
• Form a non-slip connection or termination for
flexible cord, cable (armored or unarmored).
• Provide grounding continuity of cable armor.
Cord & Cable Type
• S, SO, SV, ST, STD, SJ, SJO, SJT, SJTO, SVD
Features
• Extended range with superior strain relief.

• Reduced overall size, fits into tighter spaces.
• Gland nut designed to restrict cable bending.
Materials
Body: Steel-2920 series, Malleable Iron-4920 &
4960 series
Gland Nut, Grip: Steel-all series
Bushing: Rubber
Environment Classification
• Ordinary Locations
• Wet or dry locations
Range
Cord Range .125" to .950"
Hub Size Range d" to 1"
®
®

Steel Liquidtight Strain Relief Connectors – straight
Cat.
No.

Hub
Size

Throat
Dia.

Cord Range

A

2920
2921
2922
2930
2931
2932
2940
2941
2942

d
d
d
f
f
f
1
1
1

l
l
l
m
m
m
L
L
O

.125-.375
.310-.560
.500-.750
.125-.375
.310-.560
.500-.750
.310-.560
.500-.750
.700-.950

1a
1a
1c
1c
1c
1c
1c
1c
1e

Dimensions (in.)
B

C

C

A

B

1f
1f
1f
1A
1A
1A
1f
1f
1g

e
e
e
f
f
f
1h
1h
O

Steel Liquidtight Strain Relief Connectors – 45° angle

A

C

T&B ® Fittings

A

B

Cat.
No.

Hub
Size

4920
4921
4922
4930
4931
4932
4940

d
d
d
f
f
f
1

Throat
Dia.

Cord Range

A

Dimensions (in.)
B

F
F
F
A
A
A
n

.125-.375
.310-.560
.500-.750
.125-.375
.310-.560
.500-.750
.310-.560

1a
1a
1c
1c
1c
1c
1c

1j
1j
1k
1k
1k
1k
1w

C
l
l
l
e
e
e
A

Steel Liquidtight Strain Relief Connectors – 90° angle

B

A

C

Cat.
No.

Hub
Size

4960
4961
4962
4970
4971
4972
4980

d
d
d
f
f
f
1

Throat
Dia.

Cord Range

A

Dimensions (in.)
B

x
x
x
A
A
A
1

.125-.375
.310-.560
.500-.750
.125-.375
.310-.560
.500-.750
.310-.560

1a
1a
1c
1c
1c
1c
1c

1f
1f
1R
1A
1A
1A
2o

C
e
e
e
L
L
L
m

All items shown on this page are suitable for use in hazardous locations where general purpose equipment is specifically permitted by the NEC.
NEC 501-4(b).
U.L. File No. E-13938
CSA File No. 52391

For wire mesh grips refer to pages A119, A154.

A144

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:56 PM

Page 145

A
T&B ® Fittings

Flexible Cords and Cable Fittings
The Ranger™ Series of Nonmetallic Liquidtight
Cord Connectors
The Ranger Series Nonmetallic Liquidtight Cord Connector takes twice the cable
range of most ordinary strain relief connectors. T&B’s Ranger Connectors allow you
to reduce your inventory and save time, with one connector that can do the work of
two. The sturdy nylon material adds corrosion resistance to your installation.
Application
• Provide means for passing a cord
cable (armored or unarmored) into
an enclosure, through a bulkhead or
into a rigid conduit.
• Form a mechanical grip and water
and/or oil-resistant seal for cord and
unarmored or jacketed armored
round cables.
• Form a non-slip connection or termination for flexible cord, cable
(armored or unarmored).
• Provide grounding continuity of cable
armor.
Cord & Cable Type

• Reduced overall size, fits into tighter
spaces.
• Gland nut designed to restrict cable
bending.
Materials
Weather Stabilized Nylon, Temperature
rated -34°C to 105°C
Bushing: Rubber
Environment Classification
• Ordinary Locations
• Wet or dry locations
Range
Cord Range .Straight -.125" to .950"
90° -.125" to .750"
Hub Size Range Straight -d" to 1"
90° - d" to f"

• S, SO, SV, ST, STD, SJ, SJO, SJT,
SJTO, SVD
Features
• Extended range with superior strain relief.

®
®

Nonmetallic Liquidtight Strain Relief Connector – straight
Cat.
No.

Trade or
Hub Size

2920NM
2921NM
2922NM
2930NM
2931NM
2932NM
2940NM
2941NM
2942NM

d"
d"
d"
f"
f"
f"
1"
1"
1"

Throat
Dia.

Cord Range

A

Dimensions (in.)
B

C

.55
.55
.55
.79
.79
.79
.98
.98
.98

.125-.375
.310-.560
.500-.750
.125-.375
.310-.560
.500-.750
.310-.560
.500-.750
.700-.950

1r
1r
1u
1u
1u
1u
1u
1u
1H

2a
2a
2q
2i
2i
2i
2X
2X
2c

e
e
e
e
e
e
A
A
A

Nonmetallic Liquidtight Strain Relief Connector – 90° elbow
Cat.
No.

Trade or
Hub Size

4960NM
4961NM
4970NM
4971NM
4972NM

d"
d"
f"
f"
f"

Throat
Dia.

Cord Range

A

Dimensions (in.)
B

C

.55
.55
.79
.79
.79

.125-.375
.310-.560
.125-.375
.310-.560
.500-.750

1r
1r
1u
1u
1u

1b
1b
1c
1c
1c

e
e
e
e
e

U.L. File No. E 13938
CSA File No. 52391
Meets Coast Guard CG293

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A145

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 146

T&B ® Fittings

A
Flexible Cords and Cable Fittings
The Ranger™ Series of Aluminum Liquidtight Cord Connectors
The Ranger Series Aluminum Liquidtight Connector takes twice the cable range of
most ordinary strain relief connectors. T&B’s Ranger Connectors allow you to
reduce your inventory and save time, with one connector that can do the work of
two. The sturdy aluminum material adds corrosion resistance to your installation.
Application
• Provide means for passing a cord cable
(armored or unarmored) into an enclosure,
through a bulkhead or into a rigid conduit.
• Form a mechanical grip and water and/
or oil-resistant seal for cord and unarmored or jacketed armored round cables.
• Form a non-slip connection or termination for flexible cord, cable (armored or
unarmored).
• Provide grounding continuity of cable
armor.
Cord & Cable Type

• Reduced overall size, fits into tighter
spaces.
• Gland nut designed to restrict cable
bending.
Materials
Body: Aluminum
Gland Nut, Grip: Aluminum-all series
Bushing: Rubber
Environment Classification
• Ordinary Locations
• Wet or dry locations
Range

• S, SO, SV, ST, STD, SJ, SJO, SJT, SJTO,
SVD

Cord Range .125" to .950"
Hub Size Range d" to 1"

Features
• Extended range with superior strain relief.

®
®

Aluminum Liquidtight Strain Relief Connectors – straight
Cat.
No.

C

A

B

A146

2920AL
2921AL
2922AL*
2930AL
2931AL
2932AL
2940AL
2941AL
2942AL

Hub
Size

Throat
Dia.

Cord Range

A

Dimensions (in.)
B

C

d
d
d
f
f
f
1
1
1

l
l
l
m
m
m
L
L
O

.125-.375
.310-.560
.500-.750
.125-.375
.310-.560
.500-.750
.310-.560
.500-.750
.700-.950

1a
1a
1j
1j
1j
1j
1j
1j
1l

1f
1f
1f
1A
1A
1A
1f
1f
1g

e
e
e
c
f
f
1h
1h
O

For 1-2" Aluminum Strain Relief Connectors, see next page.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 147

A
®
®

Aluminum Liquidtight Strain Relief Connectors – straight
Cat.
No.
2541AL
2542AL
2544AL
2545AL
2546AL
2547AL
2548AL*
2549AL*
2558AL
2559AL
2556AL*
2557AL*
2562AL
2563AL
2564AL
2565AL*
2573AL
2574AL
2575AL
2576AL*
2577AL*

C

A

B

Hub
Size

Throat
Dia.

Cord Range

A

Dimensions (in.)
B

C

(.250-.375)
(.375-.500)
(.500-.625)
(.625-.750)
(.750-.880)
(.875-.985)
(.880-1.065)
(1.065-1.205)
(.880-1.065)
(1.065-1.205)
(1.187-1.375)
(1.375-1.485)
(.812-1.000)
(1.000-1.187)
(1.187-1.375)
(1.375-1.625)
(1.125-1.375)
(1.375-1.625)
(1.625-1.875)
(1.750-1.965)
(1.937-2.187)

1"
1"
1"
1"
1"
1"
1"
1"
1b"
1b"
1b"
1b"
1d"
1d"
1d"
1d"
2"
2"
2"
2"
2"

?"
?"
?"
?"
©"
©"
C"
C"
1å"
1å"
1b"
1b"
1k"
1k"
1k"
1S"
1g"
1g"
1g"
1C"
1C"

1L
1L
1L
1L
1L
1L
2h
2h
2a
2h
2j
2j
2j
2j
2b
2f
2f
2f
2f
3r
3r

1z
1z
1z
1z
1g
1g
2c
2c
2q
2q
2d
2d
2d
2k
2k
2e
2e
2e
3d
3d
3d

l
l
l
l
l
l
A
A
e
e
m
m
m
L
L
m
m
m
m
m
m

Aluminum Liquidtight Strain Relief Connectors – 90° elbow
Cat.
No.

Throat
Diam.

Cord Range

A

d
d
d
f
f
f
1
1
1

x
x
x
A
A
A
1
1
1

.125-.375
.360-.560
.500-.750
.125-.375
.310-.560
.500-.750
.310-.560
.500-.750
.700-.950

1a
1a
1j
1j
1j
1j
1j
1j
1l

4960AL
4961AL
4962AL*
4970AL
4971AL
4972AL
4980AL
4981AL
4982AL

B

A

D

Trade or
Hub Size

Dimensions (in.)
B
C
1f
1f
1R
1A
1A
1A
2o
2o
2L

e
e
e
L
L
L
m
m
m

D
1j
1j
1c
1v
1v
1v
1f
1f
2

* It may be necessary to remove sufficient outer covering of cable to permit conductors to pass through connector body.
All items shown on this page are suitable for use in hazardous locations where general purpose equipment is specifically permitted by
the NEC. NEC 501-4(b).
U.L. File No. E-13938
CSA File No. 52391
For wire mesh grips refer to pages A119, A154.

C

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A147

T&B ® Fittings

Flexible Cords and Cable Fittings

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 148

T&B ® Fittings

A
Flexible Cords and Cable Fittings
T&B Liquidtight Strain Relief Cord Connectors
The T&B Steel Liquidtight Strain Relief Cord Connector is suited for most general control
and power cable applications. This series features sturdy neoprene bushings and
tapered hub threads.
Application
• Provide means for passing a cord cable
(armored or unarmored) into an enclosure,
through a bulkhead or into a rigid conduit.
• Form a mechanical grip and water and/or oilresistant seal for cord and unarmored or jacketed armored round cables.
• Form a non-slip connection or termination for
flexible cord, cable (armored or unarmored).
• Provide grounding continuity of cable armor.
Cord & Cable Type
• S, SO, SV, ST, STD, SJ, SJO, SJT, SJTO, SVD
Features
• Extended range with superior strain relief.

• Reduced overall size, fits into tighter spaces.
• Gland nut designed to restrict cable bending.
Materials
Body: Steel-2920 series, Malleable Iron-4920 &
4960 series
Gland Nut, Grip: Steel-all series
Bushing: Rubber
Environment Classification
• Ordinary Locations
• Wet or dry locations
Range
Cord Range .125" to .950"
Hub Size Range d" to 1"
®
®

Liquidtight Strain Relief Connectors

C

A

B

Fig. 1

C

A

B

Fig. 2

Cat.
No.

Cable Size
Range
min.-max.

Throat
Dimensions (in.)
Hub Dia.
Size (min.) Fig. A
B
C

2516†
2517†
2518†
2519†
2520
2521
2522
2523
2524*
2525*
2530
2531
2532
2534
2535
2536*
2541
2542
2544
2545
2546
2547
2548*
2549*
2558
2559
2556*
2557*
2562
2563
2564
2565*
2573
2574
2575
2576*
2577*
2584
2585
2586*
2587*
2592
2593
2594
2595*
2596*

(.060-.125)
(.120-.250)
(.060-.150)
(.150-.300)
(.125-.250)
(.250-.375)
(.375-.500)
(.450-.560)
(.500-.625)
(.625-.750)
(.125-.250)
(.250-.375)
(.375-.500)
(.500-.625)
(.625-.750)
(.750-.880)
(.250-.375)
(.375-.500)
(.500-.625)
(.625-.750)
(.750-.880)
(.875-.985)
(.880-1.065)
(1.065-1.205)
(.880-1.065)
(1.065-1.205)
(1.187-1.375)
(1.375-1.485)
(.812-1.000)
(1.000-1.187)
(1.187-1.375)
(1.375-1.625)
(1.125-1.375)
(1.375-1.625)
(1.625-1.875)
(1.750-1.965)
(1.937-2.187)
(1.750-1.965)
(1.937-2.187)
(2.156-2.360)
(2.350-2.565)
(2.156-2.360)
(2.350-2.565)
(2.535-2.750)
(2.735-2.985)
(2.970-3.220)

b"
b"
c"
c"
d"
d"
d"
d"
d"
d"
f"
f"
f"
f"
f"
f"
1"
1"
1"
1"
1"
1"
1"
1"
1b"
1b"
1b"
1b"
1d"
1d"
1d"
1d"
2"
2"
2"
2"
2"
2d"
2d"
2d"
2d"
3"
3"
3"
3"
3"

R"
R"
S"
S"
l"
l"
l"
l"
e"
e"
m"
m"
m"
m"
m"
f"
?"
?"
?"
?"
©"
©"
C"
C"
1å"
1å"
1b"
1b"
1k"
1k"
1k"
1S"
1g"
1g"
1g"
1C"
1C"
2"
2"
2q"
2q"
2u"
2u"
2u"
2m"
2m"

2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

E
$
O
O
1a
1a
1a
1c
1c
1c
1c
1c
1c
1c
1c
1L
1L
1L
1L
1L
1L
2h
2h
2a
2h
2j
2j
2j
2j
2b
2f
2f
2f
2f
3r
3r
3r
3r
3n
3n
3n
3n
3n
4L
4L

1k
1k
1d
1d
1y
1y
1y
1y
1f
1f
1f
1f
1f
1f
1f
1n
1z
1z
1z
1z
1g
1g
2c
2c
2q
2q
2d
2d
2d
2k
2k
2e
2e
2e
3d
3d
3d
3f
3f
4b
4b
4b
4b
4b
4m
4m

v
v
v
v
e
e
e
e
e
e
l
l
l
l
l
e
l
l
l
l
l
l
A
A
e
e
m
m
m
L
L
m
m
m
m
m
m
1o
1o
1o
1o
1o
1o
1o
1a
1a

Bushing
Part
No.

Gland-Nut
Model
No.

Retainer
Model
No.

Body
Model
No.

035-73377-5
035-73377-6
035-73377-7
035-73377-8
053-71411-1
053-71411-2
053-71411-3
053-71411-4
053-71411-59
053-71411-60
033-72259-1
053-71411-5
053-71411-58
053-71411-59
053-71411-60
053-71411-61
053-71411-5
053-71411-58
053-71411-59
053-71411-60
053-71411-61
053-71411-62
053-71411-63
053-71411-64
053-71411-63
053-71411-64
053-71411-18
033-72259-2
033-72259-3
053-71411-17
053-71411-18
053-71411-65
053-71411-66
053-71411-65
053-71411-67
033-72259-5
033-72259-6
033-72259-5
033-72259-6
033-72259-7
033-72259-8
033-72259-7
033-72259-8
033-72259-9
033-72259-10
033-72259-11

035-73377-3
035-73377-3
035-73377-4
035-73377-4
053-71411-37
053-71411-37
053-71411-37
053-71411-37
053-71411-38
053-71411-38
053-71411-38
053-71411-38
053-71411-38
053-71411-38
053-71411-38
053-71411-39
053-71411-38
053-71411-38
053-71411-38
053-71411-38
053-71411-39
053-71411-39
053-71411-40
053-71411-40
053-71411-40
053-71411-40
053-71411-41
053-71411-41
053-71411-41
053-71411-41
053-71411-41
053-71411-42
053-71411-42
053-71411-42
053-71411-42
033-72259-17
033-72259-17
033-72259-17
033-72259-18
033-72259-19
033-72259-19
033-72259-19
033-72259-19
033-72259-19
033-72259-20
033-72259-20

035-73377-9
035-73377-9
035-73377-9
035-73377-9
035-72735-1
035-72735-1
035-72735-2
035-72735-2
035-72735-3
035-72735-3
035-72735-4
035-72735-4
035-72735-4
035-72735-3
035-72735-3
035-72735-5
035-72735-4
035-72735-4
035-72735-3
035-72735-3
035-72735-5
035-72735-5
035-72735-6
035-72735-6
035-72735-6
035-72735-6
035-72735-7
035-72735-7
035-72735-7
035-72735-7
035-72735-7
035-72735-8
035-72735-8
035-72735-8
035-72735-8
035-72735-9
035-72735-9
035-72259-14
033-72259-14
033-72259-15
033-72259-15
033-72259-15
033-72259-15
033-72259-15
033-72259-16
033-72259-16

035-73377-1
035-73377-1
035-73377-2
035-73377-2
053-71411-43
053-71411-43
053-71411-43
053-71411-43
033-72259-21
033-72259-21
053-71411-44
053-71411-44
053-71411-44
053-71411-44
053-71411-44
033-72259-22
053-71411-45
053-71411-45
053-71411-45
053-71411-45
053-71411-46
053-71411-46
033-72259-23
033-72259-23
053-71411-47
053-71411-47
033-72259-24
033-72259-24
053-71411-48
053-71411-48
053-71411-48
033-72259-25
053-71411-49
053-71411-49
053-71411-49
033-72259-26
033-72259-26
033-72259-27
033-72259-27
033-72259-28
033-72259-28
033-72259-29
033-72259-29
033-72259-29
033-72259-30
033-72259-30

For wire mesh grips refer to pages A119, A154.

A148

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 149

A

Liquidtight Strain Relief Connectors – 45°

C

A

B

Cat.
No.

Cable Size
min.-max.

Hub
Size

A

Dimensions (in.)
B

C

Throat
Dia.

2200
2201
2202
2203
2204*
2205*
2206
2207
2208
2209
2210
2211*
2213
2214
2215
2216
2217*
2218*
2219*
2220*
2221*
2222*
2223*

(.125-.250)
(.250-.375)
(.375-.500)
(.450-.560)
(.500-.625)
(.625-.750)
(.125-.250)
(.250-.375)
(.375-.500)
(.500-.625)
(.625-.750)
(.750-.880)
(.375-.500)
(.500-.625)
(.625-.750)
(.750-.875)
(.875-.985)
(.880-1.065)
(1.065-1.205)
(.880-1.065)
(1.065-1.205)
(1.187-1.375)
(1.375-1.485)

d"
d"
d"
d"
d"
d"
f"
f"
f"
f"
f"
f"
1"
1"
1"
1"
1"
1"
1"
1b"
1b"
1b"
1b"

1a
1a
1a
1a
1c
1c
1c
1c
1c
1c
1c
1L
1c
1c
1c
1L
1L
2h
2h
2h
2h
2h
2h

1s
1s
1s
1s
1u
1u
1u
1u
1u
1u
1u
1d
1d
1d
1d
1v
1v
1O
1O
1C
1C
2b
2b

l
l
l
l
l
l
e
e
e
e
e
1d
A
A
A
A
A
A
A
m
m
m
m

F
F
F
F
F
F
A
A
A
A
A
f
n
n
n
n
n
n
n
1j
1j
1Q
1Q

Liquidtight Strain Relief Connectors – 90°

B

A

C

For wire mesh grips refer to pages A119, A154.

Cat.
No.

Cable Size
min.-max.

Hub
Size

A

Dimensions (in.)
B

C

Throat
Dia.

2267
2268
2269
2270
2250*
2251*
2252
2271
2272
2273
2274*
2253*
2254
2255
2256*
2275
2276
2257*
2258*
2277
2278
2279*
2280*
2281
2282
2283*
2284
2285
2286

(.125-.250)
(.250-.375)
(.375-.500)
(.450-.560)
(.500-.625)
(.625-.750)
(.125-.250)
(.250-.375)
(.375-.500)
(.500-.625)
(.620-.750)
(.750-.880)
(.375-.500)
(.500-.625)
(.625-.750)
(.750-.875)
(.875-.985)
(.880-1.065)
(1.065-1.205)
(.880-1.065)
(1.065-1.205)
(1.187-1.375)
(1.375-1.485)
(.812-1.000)
(1.000-1.187)
(1.187-1.375)
(1.125-1.375)
(1.375-1.625)
(1.625-1.875)

d"
d"
d"
d"
d"
d"
f"
f"
f"
f"
f"
f"
1"
1"
1"
1"
1"
1"
1"
1b"
1b"
1b"
1b"
1d"
1d"
1d"
2"
2"
2"

1a
1a
1a
1a
1c
1c
1c
1c
1c
1c
1c
1L
1c
1c
1c
1L
1L
2h
2h
2h
2h
2j
2j
2j
2j
2j
2A
2A
2A

1z
1z
1z
1z
1L
1L
1f
1e
1e
1e
1e
1O
2
2
2
2
2
2y
2y
2g
2g
2m
2m
2g
2g
2g
3b
3b
3b

e
e
e
e
l
l
d
d
d
d
d
l
A
A
A
e
e
A
A
L
L
m
m
m
m
m
B
B
B

x
x
x
x
T
T
A
A
A
A
A
A
1
1
1
1
1
n
n
1j
1j
1X
1X
1v
1v
1v
1O
1O
1O

* Remove sufficient outer covering of cable to permit conductors to pass thru connector body.
† U.L. not applicable.
Complies with JIC standards.
U.L. Listed as liquidtight strain relief, and outlet bushing. CSA certified watertight.
Temperature rating 105°C.
Suitable for hazardous locations use where general purpose equipment is specifically permitted per NEC Section 501-4(b).
U.L. File No. E 13938
CSA File No. 589 & 4484

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A149

T&B ® Fittings

Flexible Cords and Cable Fittings

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 150

T&B ® Fittings

A
Flexible Cords and Cable Fittings
®
®

CHASE® Liquidtight Cord Connectors
Cat.
No.

Cable Size Range
Size (in.)

Throat
Dia.

2631
2632
2633
2634

(.125-.250)
(.250-.375)
(.375-.500)
(.450-.560)

d"
d"
d"
d"

2637
2638
2639
2640
2641

(.125-.250)
(.250-.375)
(.375-.500)
(.500-.625)
(.625-.750)

f"
f"
f"
f"
f"

2644
2645
2646
2647
2648
2649

(.250-.375)
(.375-.500)
(.500-.625)
(.625-.750)
(.750-.880)
(.885-.985)

1"
1"
1"
1"
1"
1"

Dimensions (in.)
Cord Range

B

C

l"
l"
l"
l"

1h
1h
1h
1h

1e
1e
1e
1e

A"
A"
A"
A"
A"

1j
1j
1j
1j
1j

1f
1f
1f
1f
1f

1e
1e
1e
1e
1e
1e

1m
1m
1m
1m
1m
1m

1"
1"
1"
1"
1"
1"

Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 1 and 2; Class III, Div. 1 and 2, where general purpose equipment is
specifically permitted per NEC Section 500-2(a).
Complete with “O” Ring seal and nylon insulated throat, and neoprene bushing.
U.L. Listed as liquidtight strain relief, and outlet bushing. CSA certified watertight.
Temperature Rating; 105°C.
U.L. File No. E 13938
CSA File No. 589
CHASE® Liquidtight Cord Connectors are ideal for installation where space is limited
inside the enclosure.

Multi-Hole Flexible Cord and Cable Connectors
Cat.
No.
2520-2
2530-2
2531-2
2531-3
2541-2
2542-2
2540-3
2541-3
2540-4
2555-2

Hub
Size, In.

Dia.
No.

Cord
Dia.

d"
f"
f"
1"
1"
1"
1"
1"
1"
1b"

2
2
2
3
2
2
3
3
4
2

.220
.220
.260
.260
.300
.375
.225
.300
.220
.500

Note: Range of cord dia. ± .010.
In many applications you have only room for one fitting but you need to run two cables, for example, proximity switches. Now you can
provide strain relief and liquidtight protection with T&B’s new multi-hole liquidtight strain relief connectors. With the ever increasing
number of signal cables, now you have a solution to the problem of how to strain relieve multiple cables in one fitting.

A150

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 151

A
®
®

Watertight Strain Relief Connectors (Straight)
B

Retaining Ring
Plastic (See Note 3)
A
Across
Corners

Cable
Size

Bushing
Neoprene

C

Hub TH'D Size
Taper Pipe Thread

Throat DIA

Cat.
No.

Hub
THD Size
(Taper
THD)

Cable Size
Min.
Max.

A

B
Max.

C

on
Bushing

Marking
Bushing
Part. No.

Throat
Dia.
(Min.)

2558AL
2559AL
2556AL
2557AL

1b
1b
1b
1b

.880
1.065
1.187
1.375

1.065
1.205
1.375
1.485

2p
2p
2X
2X

2q
2q
2d
2d

m
m
m
m

.880-1.065
1.065-1.205
2564
None

053-71411-63
053-71411-64
053-71411-18
033-72259-2

1å
1å
1b
1b

2562AL
2563AL
2564AL
2565AL

1d
1d
1d
1d

.812
1.000
1.187
1.375

1.000
1.187
1.375
1.625

2X
2X
2X
2m

2d
2k
2k
2e

L
L
L
m

None
2563
2564
1.375-1.625

033-72259-3
053-71411-17
053-71411-18
053-71411-65

1k
1k
1k
1S

2573AL
2574AL
2575AL
2576AL
2577AL

2
2
2
2
2

1.125
1.375
1.625
1.750
1.937

1.375
1.625
1.875
1.965
2.187

2m
2m
2m
3r
3r

2e
2e
2e
3d
3d

m
L
L
B
B

1.125-1.375
1.375-1.625
1.625-1.875
10412
10413

053-71411-66
053-71411-65
053-71411-67
033-72259-5
033-72259-6

1g
1g
1g
1C
1C

2584AL
2585AL
2586AL
2587AL

2d
2d
2d
2d

1.750
1.937
2.156
2.350

1.965
2.187
2.360
2.565

3r
3r
3n
3n

3f
3f
4b
4b

1o
1o
1o
1o

10412
10413
10414
10415

033-72259-5
033-72259-6
033-72259-7
033-72259-8

2
2
2q
2q

2592AL
2593AL
2594AL
2595AL
2596AL

3
3
3
3
3

2.156
2.350
2.535
2.735
2.990

2.360
2.565
2.750
2.985
3.220

3n
3n
3n
4L
4L

4b
4b
4b
4m
4m

1o
1o
1o
1a
1a

10414
10415
10416
None
None

033-72259-7
033-72259-8
033-72259-9
033-72259-10
033-72259-11

2u
2u
2u
2m
2m

Notes:
1. Cord or cable will not pass thru body without removing outer covering.
2. Listed under “UL” file No. E13938A and “CSA” file No. 589 except Cat. No.'s 2516, 2517, 2518, and 2519.
3. 2d" and 3" sizes have stainless steel retaining rings.
4. Cat. No. 2558AL through 2575AL have machined aluminum body with stamped sheet aluminum gland. All others have cast aluminum
body and gland. All bodies and glands are etched clean and wax coated for easy assembly.
5. Alumishield to be on gland to prevent galling of threads.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A151

T&B ® Fittings

Flexible Cords and Cable Fittings

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 152

T&B ® Fittings

A
Flexible Cords and Cable Fittings – Non-Metallic
Liquidtight Flexible Cord Connectors – Black Beauty™ Series
Listed/Certified by:

Application
• A liquidtight connector to connect
flexible cord to a box or enclosure
and provide adequate strain relief.

2672 Series

Gland

Segmented
Chuck

U.L....................(U.L. File No. E-23018)
CSA .........................LR-2884, LR-4484
Standard Material

Features
• Taper Thread hub seals in female hub
(A).
• Neoprene bushing provides liquidtight installation (B).
• Hand tightens – no tools needed for
assembly.
• Segmented chuck provides high
mechanical pullout performance –
will not cut or damage cord jacket
(C).
• Corrosion and weather resistant plastic is excellent for outdoor/indoor use.
• Plastic parts improve dielectric strength
and provide insulated throat (D).
• Wide range – reduces inventories.

Standard Finish
All parts as molded.
Range
.250 outside diameter
to 1.020 outside
diameter .......Type S, SO, SV, ST, STO,
SJ, SJO, SJT, SJTO,
SVTO, SVO, SVT Flexible
Cords & Cables
Conforms to:

(C)

Bushing

Body, Gland &
Segmented Chuck ..Weather stabilized
thermoplastic rated for -34°C (-29°F)
to 105°C (221°F) application.
Bushing.................................Neoprene

U.L. 514B
CSA C22.2 No. 18
NFPA 70-1999 (ANSI)
Federal Standard H-28 (Threads)
(B)

Body
Note:
Series 5262
Sealing Gasket
(Not provided
with connector)

2672 Series

(A)
(D)

Typical Installation

A152

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 153

A
®
®

Nonmetallic Liquidtight Strain Relief Connector – straight
Cat.
No.

• Weather Stabilized Nylon.
• U.L. 94-V2.
• Temperature Rating: -34˚C to +105˚C.
• Meets Coast Guard CG293.

Dimensions (in.)

Trade or
Hub Size

Throat
Diam. (in.)

Cord Range (in.)

A

B

C

c"
d"
d"
d"
d"
d"
f"
f"
f"
f"
f"
1"
1"
1"
1"
1b"
1b"
1b"
1d"
1d"
1d"
2"
2"
2"

0.33
0.33
0.55
0.55
0.54
0.54
0.55
0.55
0.79
0.79
0.76
0.98
0.98
0.98
0.98
1.25
1.25
1.25
1.47
1.47
1.47
1.89
1.89
1.89

.125-.275
.125-.275
.250-.400
.400-.560
.660-.780
.660-.780
.250-.400
.400-.560
.560-.690
.660-.780
.770-.895
.660-.780
.770-.895
.870-1.020
.890-1.090
.890-1.090
1.080-1.280
1.270-1.470
.890-1.150
1.140-1.400
1.390-1.650
1.190-1.530
1.520-1.860
1.850-2.190

2.0
2.3
2.6
2.6
3.0
3.0
2.7
2.7
3.0
3.0
3.2
3.3
3.3
3.3
4.2
4.2
4.0
4.0
4.2
4.3
4.3
5.1
4.9
4.9

.90
.90
1.27
1.27
1.57
1.57
1.27
1.27
1.57
1.57
1.89
1.89
1.89
1.89
2.58
2.58
2.58
2.58
2.95
2.95
2.95
3.50
3.50
3.50

.46
.60
.60
.60
.60
.60
.62
.62
.62
.62
.62
.77
.77
.77
.77
.80
.80
.80
.82
.82
.82
.84
.84
.84

2671
2690
2672
2673*
2691*
2692*
2693
2694*
2674
2675
2696*
2676
2677
2678*
2699
2702
2703
2704
2705-TB
2706
2707
2708
2709
2710*

* Remove sufficient outer covering of cable to permit conductors to pass thru connector body.
U.L. File No. E 13938
CSA File No. 52391
All items shown on this page are suitable for use in hazardous location where general purpose equipment is specifically permitted by the
NEC. Class I, Div. 2. Class II, Div. 1 & 2. Class III, Div. 1 & 2. NEC 501-4(b), 502-4(a)(b), 503-3(a)(b).

Nonmetallic Liquidtight Strain Relief Connector – 90° elbow
Cat.
No.

90° angle, standard size body.
• Weather Stabilized Nylon.
• U.L. 94-V2.
• Temperature Rating: -34˚C to +105˚C.
• Meets Coast Guard CG293.

Trade or
Hub Size

2680
2681
2682*
2683
2684
2688
2685
2686
2687*

Dimensions (in.)

Throat
Diam. (in.)

Cord Range (in.)

A

B

C

.33
.55
.55
.78
.78

.125-.275
.250-.400
.400-.560
.560-.690
.660-.780

C

1f

.460

.98
.98
.98
.98

.560-.690
.660-.780
.770-.895
.870-1.020

1B
1B
1B
1B

3b
3b
3i
3

.770
.770
.770
.770

c"
d"
d"
f"
f"
1"
1"
1"
1"

* Remove sufficient outer covering of cable to permit conductors to pass thru connector body. 90° angle, standard size body.
U.L. File No. E 13938
CSA File No. 52391
All items shown on this page are suitable for use in hazardous locations where general purpose equipment is specifically permitted by the
NEC. Class I, Div. 2. Class II, Div. 1 & 2. Class III, Div. 1 & 2. NEC 501-4(b), 502-4(a)(b), 503-3(a)(b).

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A153

T&B ® Fittings

Flexible Cords and Cable Fittings – Non-Metallic

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 154

T&B ® Fittings

A
Wiremesh Grips
The T&B WMG-PC Series Wiremesh Grips for Portable Cord
T&B Wiremesh grips are ordered separately and fit with your existing inventory of
Ranger™ connectors and liquidtight strain relief connectors. There’s no need to
duplicate inventory.
Wiremesh grips support the following
Liquidtight Cord Fittings Series.

2920 Series

2920AL Series

Application

Features

• Provides high gripping strength for adequate cable support and strain relief
without damage to the cable sheath
• Compression of a tapered neoprene
bushing, assures the watertight
integrity of the fittings
• To meet National Electric Code or
NEC requirements for electrical installations in hazardous atmospheres, a
sealing fitting may be required in conjunction with the cable and cord fitting

• Prevents severe cord bends and
pullouts
• Used in aluminum and/or steel fittings

Cord & Cable Type

Materials
Wiremesh made of stainless steel.
Retaining rings made of aluminum.
Environment Classification
• Ordinary Locations
Range
.187 – 3.220

• S, SO, SV, ST, STD, SJ, SJO, SJT,
SJTO, SVD

How to select proper wiremesh grip:
1. Determine O.D. of portable cord e.g. .200
2. Determine size of knockout or threaded hub e.g. d"
3. Select Cat. No. of strain relief connector e.g. 2520, 2920AL.
4. Match up O.D. with grip range and strain relief to determine Cat. No.
of Wiremesh Grip (e.g. .200 + 2520 = WMP-PC1)

2516 Series

®
®

Wiremesh Grips for Portable Cord
Strain Relief Connector
Straight
Cat.
No.

Grip
Range

Ranger™ Ranger™
Steel Aluminum

WMG-PC1
WMG-PC2

.187-.250
.250-.375

2920
2920

WMG-PC3

.375-.500

WMG-PC4

.500-.625

T&B
Steel

Ranger™
Steel

Ranger™
Aluminum

T&B
Steel

2920AL
2920AL

2520
2521

4920
4920

2200
2201

4960
4960

4960AL
4960AL

2267
2268

2921
2922
2932
2941

2921AL
2922AL
2932AL
2941AL

2522
2524
2534
2544

4921
4922
4932
4941

2202
2204
2209
2214

4961
4962
4972
4981

4961AL
4962AL
4972AL
4981AL

2269
2250
2273
2255

2922AL
2932AL
2941AL
2930AL

2525
2535
2545
2530

4922
4932
4941
4930

2205
2210
2215
2206

4962
4972
4981
4970

4962AL
4972AL
4981AL
4970AL

2251
2274
2256
2252

2531
2541
2532
2542

4930

2207

4970

4970AL

2271

4931
4940

2208
2213

4961
4980

4961AL
4980AL

2272
2254

4942

2211
2216
2217

4982

4982AL

2253
2275
2276

.625-.750

WMG-PC6

.187-.250

WMG-PC7

.250-.375

2930

2930AL

WMG-PC8

.375-.500

2931
2940

2931AL
2940AL

WMG-PC9

.750-.875
2942

2942AL

WMG-PC11

.875-1.000

WMG-PC12

1.000-1.125

WMG-PC13

1.125-1.250

2536
2546
2547
2548
2558
2548
2558
2549
2559

2257
2277
2257
2277
2258
2278

–
–

1.375-1.500

2256
2564
2557

2222
—
2223

2279
2283
2280

1.125-1.250

2573

–

2284

1.125-1.250

WMG-PC15

1.250-1.375

WMG-PC16*
WMG-PC17*

2549
2559
2556
2563
2564

2218
2220
2218
2220
2219
2221

2219
2278
2222
2282
2283

WMG-PC14

A154

90°

Ranger™
Steel

WMG-PC5

.875-1.000

45°
T&B
Steel

2922
2932
2941
2930

WMG-PC10

Strain Relief Connector

2258

2258

2279

2279

2221

Straight

90°

Grip
Range

T&B
Steel

T&B
Steel

WMG-PC18*
WMG-PC19*

1.250-1.375
1.375-1.500

2573
2565
2574

2284
2285

WMG-PC20*

1.500-1.625

2285

WMG-PC21*

1.625-1.750

2565
2574
2575

WMG-PC22*
WMG-PC23

1.750-1.875
1.750-1.875

2575
2576
2584

2286

WMG-PC24

1.875-2.000

WMG-PC25

1.937-2.062

2576
2584
2577
2585

WMG-PC26*

2.062-2.187

WMG-PC27

2.125-2.250

WMG-PC28

2.250-2.375

WMG-PC29

2.350-2.475

WMG-PC30

2.475-2.600

WMG-PC31*

2.625-2.750

2587
2593
2594
2594

WMG-PC32*
WMG-PC33*

2.735-2.860
2.860-2.985

2595
2595

WMG-PC34*
WMG-PC35*

2.970-3.095
3.095-3.220

2596
2596

Cat.
No.

2286

2577
2585
2586
2592
2586
2592
2587
2593

*Replacement Gland Nut Supplied With
These Cat alog Numbers Only

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 155

A
T&B ® Fittings

Non-Metallic Cable Glands
Low profile cable gland perfect for tight spots
T&B Nylon Cable Glands have a sturdy cable sealing mechanism which results in
superior strain relief. The compact size ensures quick and easy installation in
cramped spaces. The non-metallic construction provides excellent corrosion,
chemical and impact resistance. The glands have long threads and locknuts are
available.
• Halogen free
• Flame Retardant UL 94V0
• Rated IP 68 5 BAR, suitable for
NEMA 4 enclosures
• UL Listed*, CSA listed
for certain ranges of cable
• Working Temperatures -30˚C(-86F) to
+80˚C(176˚F)
Continuous, +150˚C(276˚F) Intermittent
• Meets VDE ratings
Sturdy Nylon 6 for strong, lightweight
construction. Gray color shown, also
available in black.
®
®

Non-Metallic Cable Glands
Catalog No.
Fittings

Cord Range

Length of Thread
In.
MM

Thread
Size

Color

In.

MM

NPT Threads
CC-NPT38-B
CC-NPT38-G
CC-NPT12-B
CC-NPT12-G
CC-NPT34-B
CC-NPT34-G
CC-NPT1-B
CC-NPT1-G

c"
c"
d"
d"
f"
f"
1"
1"

BLACK
GRAY
BLACK
GRAY
BLACK
GRAY
BLACK
GRAY

.197-.394
.197-.394
.394-.551
.394-.551
.512-.709
.512-.709
.709-.984
.709-.984

5-10mm
5-10mm
10-14mm
10-14mm
13-18mm
13-18mm
18-25mm
18-25mm

.590
.590
.590
.590
.590
.590
.709
.709

ISO/Metric Threads
CC-ISO16-G
CC-ISO20-G
CC-ISO25-G
CC-ISO32-G

16
20
25
32

GRAY
GRAY
GRAY
GRAY

.197-.394
.236-.473
.512-.709
.709-.984

5-10mm
6-12mm
13-18mm
18-25mm

7
9
11
13d
16
21
29
36

GRAY
GRAY
GRAY
GRAY
GRAY
GRAY
GRAY
GRAY

.118-.256
.157-.315
.197-.394
.236-.473
.394-.551
.512-.709
.709-.984
.867-1.26

3-6.5mm
4-8mm
5-10mm
6-12mm
10-14mm
13-18mm
18-25mm
22-32mm

PG Threads
CC-PG7-G
CC-PG9-G
CC-PG11-G
CC-PG135-G
CC-PG16-G
CC-PG21-G
CC-PG29-G
CC-PG36-G

Use T&B
Locknut Cat. No.

Unit
Pkg.

Std.
Pkg.

15mm
15mm
15mm
15mm
15mm
15mm
18mm
18mm

–
–
LN501
LN501
LN502
LN502
LN503
LN503

50
50
50
50
25
25
20
20

250
250
250
250
100
100
100
100

.394
.590
.590
.590

10mm
15mm
15mm
15mm

LN-ISO16-G
LN-ISO20-G
LN-ISO25-G
LN-ISO32-G

50
50
25
20

200
200
100
100

.315
.315
.315
.354
.394
.433
.433
.512

8mm
8mm
8mm
9mm
10mm
11mm
11mm
13mm

LN-PG7-G
LN-PG9-G
LN-PG11-G
LN-PG135-G
LN-PG16-G
LN-PG21-G
LN-PG29-G
LN-PG36-G

50
50
25
25
25
10
10
10

200
200
100
100
100
50
50
50

*Listed under UL file E13938, control #137B NPT and PG threaded Cable Glands are UL Listed, ISO/Metric Threaded Cable Glands are not UL Listed.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A155

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 156

T&B ® Fittings

A
Service Entrance Cable Fittings
Suggested Specifications for Service Entrance Fittings
Series 4175
Pipe Strap (EMT)

Series 1275/1275AL
Pipe Strap
(Rigid Metal Conduit & I.M.C.)

Series 1350/1350AL
Pipe Spacer
(Rigid Metal Conduit I.M.C. & EMT)

Series 1490
Entrance ELL

• All service fittings shall be approved for
the purpose by a nationally recognized
testing laboratory, inspection agency,
or product evaluation organization.
• Where service raceway consists of a
rigid metal conduit, intermediate
metal conduit, electrical metallic tubing or where service entrance cable
is used as service conductors, a suitable rain tight service head conforming to Federal Standard W-C-586
shall be provided.
• Service raceway shall be securely
fastened in place to the supporting
surface at intervals as specified by
the Code using suitable straps and
spacers; straps and spacers shall be
of malleable iron or steel construction,
hot dipped galvanized or electro zinc
plated conforming to Canadian
Standards Association Standard
C22.2 No. 18 and as manufactured
by Thomas & Betts: series 1275 or
4175 straps and series 1350 spacers;
aluminum straps or spacers such as
series 1275AL and series 1350AL
may be substituted when installed in
environmental conditions that are
more than normally corrosive.

• Where threaded rigid metal service
raceway enters the building the raceway shall be equipped with a cast
malleable iron/copper free aluminum
entrance ell suitably bushed with a
burr free end stop and taper tapped
holes as manufactured by Thomas &
Betts, series 1490.
• For grounding and bonding of service raceway, end of raceway or the
terminating fitting shall be equipped
with bonding locknuts and insulated
metallic grounding and bonding
bushing as required.
Bonding locknuts shall be of hardened steel or malleable iron construction, electro zinc plated, and provided with hardened bonding screws as
manufactured by Thomas & Betts,
series 106 bonding locknuts.
Insulated metallic grounding and
bonding bushing shall be of malleable
iron/steel construction, electro zinc
plated and assembled with an insulator listed or certified for 150°C/302°F
service as manufactured by Thomas
& Betts, series 3870.

Series 3870
Bonding & Grounding Bushing – Insulated

Series 106
Bonding Locknut

A156

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 157

A
T&B ® Fittings

Service Entrance Cable Fittings
Suggested Specifications for Service Entrance Fittings –
(Continued)

Series 2111
Service Entrance Cable Connector

Series 2116
Underground Feeder Cable Connector

Series 3302M
Two Screw Connector (Insulated)

Series 5262, 5302
Sealing Gasket

• Where service entrance cable is used
as overhead service conductors and
code requires use of a service head,
entrance caps shall be installed; caps
shall be cast metal type of suitable
ferrous or non ferrous metal equipped
with thermoset insulators and proper
knockout openings; caps when
installed with proper drip loop must
assure rain tight conditions.
• Terminating fittings for service
entrance cable (Type SE or USE) or
underground feeder and branch – circuit cable (Type UF) in locations
where exposed to intermittent or constant moisture or in dry locations and
subjected to mechanical strain shall
be of watertight strain relief type as
manufactured by Thomas & Betts,
series 2111 or 2116; fittings shall be
constructed of ferrous or non ferrous
metal and equipped with taper threaded hub, beveled moisture resistant/oil
resistant synthetic rubber bushing.
In dry locations nylon insulated two
screw type fittings of malleable
iron/steel construction electro zinc
plated inside outside including
threads such as series 3302M manufactured by Thomas & Betts may
be substituted.

•Where service entrance cable is terminated into a threadless opening
using hub type fittings, a gasket shall
be provided between the outside of
box or enclosure and fitting shoulder;
gasket shall be of moisture
resistant/oil resistant synthetic rubber
type adequately protected by and
permanently retained to a metallic
retainer as manufactured by Thomas
& Betts, series 5262 or 5302.
• Service entrance cable shall be adequately supported at intervals enumerated in code using cable straps
conforming to requirements of
Canadian Standards Association
Standard CSA 22.2 No. 18; cable
straps shall be of malleable iron/steel
construction, hot dipped galvanized
or electro zinc plated as manufactured
by Thomas & Betts, series 1341.
• At the point where the service cable
enters the building a suitable sill
plate shall be provided; sill/wall
plate shall be sealed to assure rain
tight conditions.

Series 1341
Cable Strap

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A157

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 158

T&B ® Fittings

A
Service Entrance Cable Fittings
Service Entrance Cable Connector
(Type SE/Type Use)
Range

(c)

Oval (Flat) Cable Size….260 x .500 thru 1.062 x 1.765
Type USE Cable Size…3 #12 thru 3-4/0 AWG Conductors
Hub Size…d" thru 2" NPT (taper pipe threads)
(d)
(a)

(b)
2111 Series

Application
• To connect service entrance cables to a meter box or an
enclosure.
Standard Material/Finish

Features
• Neoprene bushing, resists oil and water; grips cable the
full length of the bushing providing adequate strain relief
without damaging outer jacket (A).
• Taper threaded body (B).
• Stainless steel retaining ring protects cable jacket against
abrasion; reduces installing torque effort (C).
• Rugged ribbed steel gland construction (D).
• Suitable for Type SE & USE Service Entrance Cable.
Listed by:
U.L. (U.L. File No. E15170)
CSA (LR589, LR4484)
Conforms to:

Body…Zinc Die Cast/as cast
Gland…Steel/Electro Zinc Plated & Chromate Coated
Retaining Ring…Stainless Steel/Passivated
Bushing…Neoprene/as molded

UL514, NEMA FB1, Federal Standard
H-28 (Threads), NFPA70-1999 (ANSI)

Underground Feeder Cable Connectors
Range

(c)

Oval (Flat) Cable Size….235 x .500 thru .260 x .740
Hub Size…d" thru 1" NPT (tapered pipe threads)
(d)
(a)

(b)
2116 Series

Features
• Neoprene bushing resists oil and water; grips cable the full
length of the bushing providing adequate strain relief without damaging outer jacket (A).
• Taper threaded body (B).
• Stainless steel retaining ring protects cable jacket against
abrasion; reduces installing torque effort (C).
• Rugged ribbed steel gland construction (D).

Application
• To connect underground feeder cables to a box or an
enclosure.

Listed by:

Standard Material/Finish

Conforms to:

Body…Zinc Die Cast/as cast
Gland…Steel/Electro Zinc Plated & Chromate Coated
Retaining Ring…Stainless Steel/Passivated
Bushing…Neoprene/as molded

UL514B, NEMA FB1, Federal Standard
H-28 (Threads), NFPA70-1999 (ANSI)

A158

U.L.
CSA (LR2884)

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 159

A
®
®

Underground Liquidtight Feeder Cable Fittings
Dimensions (in.)

Oil and water resistant neoprene bushing is
especially designed for sealing around underground feeder cable. Stainless steel retaining
ring provides a bearing surface for the glandnut
and eliminates cable twist. Ribbed glandnut is
strong and easily tightened with a wrench to
make a connection of high strength.

Cat.
No.
2116-TB*
2237
2238
2239

Hub
Size

Cable
Opening

d"
f"
f"
f"

.235 x .500
.230 x .430
.235 x .465
.240 x .685

A

1L
1l
1l
1l

B

e
l
l
l

C

1
1r
1r
1r

D

E

min.

max.

min.

max

.060
.080
.050
.060

.235
.230
.235
.240

.350
.320
.340
.500

.500
.430
.465
.685

F

G

H

l
m
m
m

1a
1c
1c
1c

1a
1c
1c
1c

* Not CSA Certified.
U.L. File No. E-23017
CSA File No. 2884

®

Cable Straps
Dimensions (in.)

Cat.
No.

Each strap takes a wide range of sizes because
of the rocking action of the foot. Hole is for 1⁄4"
screw. Malleable iron, hot dipped galvanized
construction.

Wire Size

A

B

1341-TB
1344

2-#10
3-#6 or 3-#8

e
e

1a
1n

1345*
1346
1347

3-#4 or 3-#2
3-1/0
3-4/0

m
f
f

1∂
2k
2A

* Steel, hot dipped galvanized.
U.L. not applicable.
CSA Certified.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A159

T&B ® Fittings

Service Entrance Cable Fittings

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 160

T&B ® Fittings

A
Service Entrance Cable Fittings
®
®

Watertight Connectors for Oval Cable

A design with two tapers inside the body – a
slow one and a fast one – permits the stocking
of fewer connectors for varied cable sizes and
allows maximum take-up. The tapered neoprene bushings are resistant to oil, sunlight,
and water. Hex gland and body take the same
wrench opening and a stainless steel slip ring
prevents cable from twisting as gland ring is
being tightened. Threads on the body are
tapered for watersealing.

Dimensions (in.)

Oval Cable Range

Cat.
No.

Hub
Size

A

B

C

D

E

max.

2111

d"

1f

1b

e

1c

1c

.420 x .560

.380 x .520

2232
2233
2234

f"
f"
f"

1c

.385 x .600
.500 x .750
.555 x .800

.260 x .500
.375 x .625
.490 x .675

1f

.385 x .600
.500 x .750
.555 x .800

.260 x .500
.375 x .625
.430 x .675

.565 x .855
.635 x .975

.440 x .730
.510 x .850

.635 x .975
.640 x 1.050
.750 x 1.150

.510 x .850
.490 x .900
.565 x .965

.840 x 1.275
.880 x 1.425

.655 x 1.090
.695 x 1.240

.968 x 1.500
1.062 x 1.765
1.820 x 1.190

.790 x 1.390
.850 x 1.550
1.700 x 1.050

1L
2432
2433
2434

1"
1"
1"

2438
2439

1"
1"

2442
2443
2446

1b"
1b"
1b"

2454
2447

1d"
1d"

2448
2449
2450

2"
2"
2"

1b

l

min.

1c

1f

1d

A

1L

1f

2h

1n

e

2h

2a

2b

2a

2j

2j

2c

2e

2f

2u

L

U.L. File No. E-15170
CSA File No. 589
Note/Reminder: These may be obsoleted and replaced.

®
®

Nylon UF Cable Fittings for Corrosive Environments
• Tapered threaded hub.
• Liquidtight and Dust tight; hand tightens – no
tools required.
• Corrosive and weather resistant nylon for outdoor and indoor applications.

Cat.
No.

Hub
Size

A

B

C

max.

UF Cable Range
min.

max.

± .060

± .060

2827
2828
2829

d"
f"
f"

.550 x .280
.675 x .280
.775 x .280

.400 x .190
.525 x .190
.625 x .190

2.60
3.00
3.00

1.270
1.570
1.570

.600
.620
.620

U.L. File No. 15170
CSA File No. 589

A160

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 161

A
Armored Cable and Flexible Metal Conduit
Armored Cable (Type AC) – Ref. NEC
Article 333
National Electric Code defines type AC
armored cable as, “A fabricated
assembly of insulated conductors in a
flexible metallic enclosure.”
ACT
indicates an armored cable
employing conductors having
thermoplastic (Type T) insulation.
AC
indicates an armored cable
employing conductors having
rubber insulation of code
grade.
ACH
indicates an armored cable
employing conductors having
rubber insulation of the heat
resistant (75°C) grade.
ACHH indicates an armored cable
employing conductors having
rubber insulation of the heat
resistant (90°C) grade.
ACU
indicates an armored cable
employing conductors having
rubber insulation of latex grade.
‘L’
used as a suffix indicates
that a lead covering has
been applied over the conductor assembly.

All above cables may employ copper
or aluminum or copperclad aluminum
conductors with the following sizes and
are rated for 600 volts or less:
No. 14 AWG to No. 1 AWG Copper
No. 12 AWG to No. 1 AWG Aluminum
or Copperclad Aluminum
Type AC cables except ACL carry
an internal bonding strip of copper or
aluminum in intimate contact with the
armor for its entire length. Armored
cable can be used for both exposed or
concealed locations. With lead covered conductors (Type ACL) the cable
can be embedded in masonry or concrete and can be used in damp locations or where exposed to oil.
Armored cable is not permitted in
locations where it will be subjected to
physical damage or corrosive fumes.
Armored cable cannot be used for
direct burial in earth.
With minor exceptions armored
cable is also not permitted to be used
in hoists or elevators, storage battery
rooms, any hazardous locations, in
commercial garages and in theaters or
similar locations.
Codes require that cable shall be
supported with straps or staples without damaging conductors and also
limit the minimum bend radius to 5
times the diameter of type AC cable.
Certain precautions are prescribed in
code where cable is installed through
joist rafters or similar wood members.

Please Note
The excerpts and other material herein, whether relating
to the National Electrical Code, the Underwriters
Laboratories, Inc. listing, to industry practice or otherwise, is
not intended to provide all relevant information required for
use and installation. Reference to original or primary source
material and data is mandatory before any application or
use is made of the product.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

According to NEC 333-9 where
armored cable is terminated, a fitting
is required to protect conductors from
abrasion. In addition a bushing is
required between the conductors and
armor. Design of fitting has to be such
that the insulating bushing is visible for
inspection. Bushing is not required
with lead covered cables when properly installed.
Portions of this section reprinted by
permission from NFPA 70-1999,
National Electrical Code®, Copyright ©
1977, National Fire Protection
Association, Boston, MA.
Please refer to the following for further
details and complete information:
1. NEC Article 333…Armored Cable
(Type AC Cable)
2. U.L. 4, ANSI C33.9…Safety
Standards for Armored Cable
3. U.L. 514B, Safety Standards for
Outlet Boxes and Fittings
4. W-F-406…Federal Specification.
Fittings for Cable, Power,
Electrical and Conduit, Metal,
Flexible
5. NEMA FB-1…Standards
Publication. Fittings & Supports for
Conduit
and Cable Assemblies
6. CEC Section 12-700…Wiring
Methods (Armored Cable)
7. CSA C22.2 No. 51…Safety
Standards for Armored Cables
8. CSA C22.2 No. 18…Safety
Standards for Outlet Boxes,
Conduit Boxes and Fittings

A161

T&B ® Fittings

Armored Cable and Flexible Metal Conduit Fittings

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 162

T&B ® Fittings

A
Armored Cable and Flexible Metal Conduit Fittings
Armored Cable and Flexible Metal Conduit – continued
Flexible Metal Conduit – Ref. NEC Article 350
Flexible metal conduit can be used for
exposed or concealed work in dry
locations. It can be used for wet locations provided conductors within are
lead covered or other approved type.
Flexible metal conduit cannot be
used underground or embedded in
poured concrete or aggregate. With
rubber covered conductors the conduit
cannot be exposed to oil, gasoline or
other materials having a deteriorating
effect on rubber.
With minor exceptions use of flexible
metal conduit is not permitted in hoists,
in storage battery rooms and in any
hazardous locations. Use of flexible
metal conduit is restricted to systems
under 600 volts.
According to NEC Article 350-5, flexible metal conduit no longer than six feet
and containing circuit conductors protected by overcurrent device rated for
20 amps or less is suitable as a grounding means provided, it is terminated in
fittings approved for the purpose.

A162

Flexible metal conduit longer than
six feet is permitted to be used as a
grounding means provided the conduit
and the fitting are approved for the
purpose. To date there is no flexible
metal conduit approved for the purpose by the Underwriters Laboratories.
In Class I & II, Division 2 hazardous
areas, the conduit itself cannot be
used as the grounding means. A bonding jumper must be installed in accordance with NEC Section 250-79(e).
Flexible metal conduit is available with
steel or aluminum armor in trade size
j" to 4". With few exceptions where j"
and c" trade sizes are used, Code prohibits use of conduit less than d" trade
size. Bends in concealed work are
restricted to 360 degrees total. No
angle connectors are permitted in concealed raceway installations.
Portions of this section reprinted by
permission from NFPA 70-1999,
National Electrical Code®,
Copyright © 1977, National Fire
Protection Association, Boston, MA.

Please refer to the following for further
details and complete information:
1. NEC Article 350…Flexible Metal
Conduit
2. U.L. 1, ANSI C33.92…Safety
Standards for Flexible Metal
Conduit
3. U.L. 514B, Safety Standards for
Outlet Boxes and Fittings
4. W-F-406…Federal Specification.
Fittings for Cable, Power, Electrical
and Conduit, Metal Flexible
5. WW-C-566…Federal Specification.
Conduit, Metal, Flexible
6. NEMA FB1…Standards
Publication. Fittings and Supports
for Conduit and Cable Assemblies
7. CEC 12-1100…Wiring Method
(Rigid & Flexible Conduit)
8. CSA C22.2 No. 56…Safety
Standards for Flexible Metallic
Conduit and Liquid-Tight Flexible
Metal Conduit
9. CSA C22.2 No. 18…Safety
Standards for Outlet Boxes,
Conduit Boxes and Fittings

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 163

A
T&B ® Fittings

Armored Cable and Flexible Metal Conduit Fittings
Suggested Specifications for Armored Cable and
Flexible Metal Conduit Fittings

Series 3110
Armored Cable Connector &
Flexible Metal Conduit

• Armored cable (metal clad cable type
AC) and flexible metal conduit shall
conform to provisions of following
applicable standards:
Armored Cable…U.L. 4/ANSI
C33.9/CSA 22.2 No. 51
Flexible Metal Conduit…U.L. 1/ANSI
C33.92/WW-C-566/CSA 22.2 No. 56

Series 422
Insuliner® Sleeve

Type of cable used and conductors
within flexible metal conduit shall be
suitable for conditions of use and
location.
• Where armored cable or flexible
metal conduit terminates into a
threadless or threaded opening, it
shall be assembled with approved fittings; fittings shall be of malleable
iron/steel construction, electro zinc

plated inside outside, equipped with
nylon insulated throat and shall be of
angled saddle type as manufactured
by Thomas & Betts, series 3110.
Direct bearing screw type fittings
shall not be used.
Suitable bushing as manufactured by
Thomas & Betts, series 422 or 390,
shall be provided between the conductors and armor.
• Where approved armored cable or
flexible metal conduit is used as an
equipment grounding conductor terminating fitting used shall be of the
grounding type as manufactured by
Thomas & Betts, series 3110.

Series 390
Anti Short Bushing

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A163

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 164

T&B ® Fittings

A
Armored Cable and Flexible Metal Conduit Fittings
Armored Cable & Flexible Metal Conduit Connectors

3110 Series

Application
• To connect and effectively bond
armored cable or flexible metal conduit to a box or an enclosure.
Features
• Provided with a saddle designed to:
(1) Firmly secure conduit in place
without damaging cable armor
(Mechanical holding power of
angled wedge assembly increases with increased strain.).
(2) Provide high quality bond
between conduit or cable and is
unaffected by vibrations.
(3) Centralize conduit or cable with
respect to throat opening for
conductors.
• Insulated throat protects conductors
during and after installation, reduces
wire pull effort and prevents thread
damage in handling.
• Locknuts designed to provide effective bond between connector and box
or enclosure, will not vibrate loose.
• Designed with fewer screws –
reduces installation time and cost.

Range
3110 Series Straight Connectors
3130 Series 90° Connectors

• Rugged all steel or malleable iron
construction.
• Suitable as a grounding means per
N.E.C. Article 350-5 (thru 3" trade
size only).
• Suitable for hazardous location use per
Class 1 Division 2 N.E.C. 501-4 (b).
Standard Material/Finish
Body.................Steel or malleable iron/
Electro Zinc Plated &
Chromate Coated
Saddle ...........Steel/Electro Zinc Plated
& Chromate Coated
Screws .......Steel/Electro Zinc Plated &
Chromate Coated
Insulator.......Thermoplastic/As Molded
Conforms to:
U.L. 514B
CSA C22.2 No. 18
NEMA FB1
Listed/Certified by:
U.L.
CSA

(U.L. File No. 23018)
(LR-2884, LR-4484)

Hub Size

Conduit Size

Cable Opening

b" thru 5" NPS
b" thru 4" NPS

c" thru 5"
c" thru 4"

.437" to 5.500"
.437" to 4.560"

(All hubs provided with
straight pipe threads NPS.)

Saddle

Locknut

Body
Insulated Throat

A164

Typical
Installation

Box or Enclosure Wall

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 165

A
®
®

TITE-BITE® Connectors* – Nylon Insulated
Cat.
No.

Steel or malleable iron.
The tough lining of insulation and the Tite-Bite®
principles make these connectors a “must”
when conductors are subject to conditions of
vibration or strain.

3110**
3112
3115
3117
3118***
3119***
3120***
3121***
3122***
3123***††
3124***
3125†††

Cable
Opening

Dimensions (in.)

max.

min.

Trade
Size

K.O.
Size

A†

B

C

.656
.937
1.125
1.468
1.750
2.031
2.500
3.062
3.562
4.060
4.560
5.500

.437
.750
.906
1.250
1.562
1.812
2.312
2.812
3.312
3.620
4.120
4.600

c"
d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
5"

d"
d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"
5"

1b
1b
1A
2c
2f
3a
3f
4c
5
–
–
–

1a
1a
1f
1f
2
2e
2f
3b
3b
–
–
–

g
g
1r
1a
1b
1f
1m
2b
2b
–
–
–

* U.L. Listed as a grounding means under NEC 350-5.
** U.L. Listed for armored cable only.
*** U.L. Listed for flexible metal conduit only.
Material: Steel thru f" trade size.
†
Approximate dimension with screw at minimum height.
U.L. File No. E 23018
CSA File No. 2884
††
CSA not applicable.
†††
Not U.L. Listed or CSA Certified.
®
®

TITE-BITE® Connectors*
Cat.
No.

Steel or malleable iron.
Easy to install with double grip saddle. These
connectors are completely salvageable. The 2⁄3"
and 1⁄2" sizes are made of formed steel which
produce a uniform high quality and a smooth
throat that protects conductor insulation. 3⁄4"
and larger size are malleable iron.

300TB**
302
304
306
308***
310***
312***
314***
316***

Cable
Opening
max.

min.

Trade
Size

.656
.937
1.093
1.468
1.750
2.031
2.500
3.062
3.562

.437
.750
.906
1.250
1.562
1.812
2.312
2.812
3.312

c"
d"
f"
1"
1b"
1d"
2"
2d"
3"

Dimensions (in.)

K.O.
Size

A

d"
d"
f"
1"
1b"
1d"
2"
2d"
3"

1b
1e
1g
2h
2j
2e
3a
3d
4h

†

B
1j
1L
1L
1f
2o
2l
2m
3a
3i

C
k
1ƒ
1r
1a
1b
1f
1m
2b
2b

* U.L. Listed as a grounding means under NEC 350-5.
** U.L. Listed for armored cable only.
*** U.L. Listed for flexible metal conduit only.
†
Approximate dimension with screw at minimum height.
U.L. File No. E 23018
CSA File No. 2884
Material: Steel thru f" trade size.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A165

T&B ® Fittings

Armored Cable and Flexible Metal Conduit Fittings

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 166

T&B ® Fittings

A
Armored Cable and Flexible Metal Conduit Fittings
®
®

TITE-BITE® Connectors* – 90° angle nylon insulated
Cat.
No.

Steel or malleable iron.
Available with or without insulated throat, this
Tite-Bite® connector line is by far the easiest
and best to install when making sharp bends at
the enclosure or equipment. It has all of the
advantages of the straight connector with only
one screw to tighten, except in the larger sizes
where there are two. A peep hole on top provides for easy inspection of the ABC bushing.
Narrow design makes it easy to install connectors in adjacent knockouts.

3130*
3132*
3135*
3137
3138***
3139***
3140***
3141***
3142***
3143†††
3144***

Cable
Opening

Dimensions (in.)

max.

min.

Trade
Size

K.O.
Size

A†

.656
.937
1.093
1.468
1.750
2.031
2.500
3.062
3.562
4.060
4.560

.437
.750
.906
1.250
1.562
1.812
2.312
2.812
3.312
3.620
4.120

c"
d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

d"
d"
f"
1"
1b"
1d"
2"
2d"
3"
3d"
4"

1X
1g
2a
2y
3j
4
4n
6s
7X
–
–

B

C

1x
2j
2a
2a
3s
4a
5h
6
7h
–
–

n
n
l
d
l
L
L
f
f
–
–

* U.L. Listed as a grounding means under NEC 350-5.
*** U.L. Listed for flexible metal conduit only.
†
Approximate dimension with screw at minimum height.
†††
Not U.L. Listed or CSA Certified.
U.L. File No. E 23018
CSA File No. 2884
®
®

TITE-BITE® Connectors* – 90° angle

The angle clip gives secure mechanical grip
that tightens under tension or vibration.
Throat is long enough to install in cast housing knockouts. The 3⁄8" and 1⁄2" sizes are of
steel construction. The 3⁄4" and larger sizes
are malleable iron.

Cable
Opening

Dimensions (in.)

Cat.
No.

max.

min.

Trade
Size

K.O.
Size

A†

B

C

321
323
325
326TB
327***
328***
329***
330***
331***

.656
.937
1.093
1.468
1.750
2.031
2.500
3.062
3.562

.437
.750
.906
1.250
1.562
1.812
2.312
2.812
3.312

c"
d"
f"
1"
1b"
1d"
2"
2d"
3"

d"
d"
f"
1"
1b"
1d"
2"
2d"
3"

1X
1g
2a
2y
3a
4a
4c
6d
5A

1d
2c
2a
2a
3e
4a
4O
6
7

c
w
f
1
–
–
–
–
–

* U.L. Listed as a grounding means under NEC 350-5.
*** U.L. Listed for flexible metal conduit only.
†
Approximate dimension with screw at minimum height.
U.L. File No. E 23018
CSA File No. 2884

®
®

TITE-BITE® Aluminum Sheathed Cable Connectors
Cat. No.
2492

• Unique saddle design firmly secures cable in
place, provides holding power in excess of
listing agency requirements, and assures
high quality bonding.
• Removable bushing design covers wide
range, reduces inventories.
• Can be used on smooth or corrugated aluminum sheathed and steel MC cable.
• One screw provides quick installation.

A166

Dia. Range
Alum.
Sheath (in.)

Hub
Size

(.370-.500)

d"

U.L. Listed as a grounding means for steel MC cable and ALS. For dry location.
U.L. File No. E 36017
CSA File No. 589
Tite-Bite® Connectors are approved for continous sheathed corrugated MC cable.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 167

A
®
®

Squeeze Connectors*
Cat.
No.

T&B squeeze connectors will fit every size of
armored cable, leaded cable and flexible conduit. Malleable iron or steel construction. Part
No. 253 is steel.

252***
253TB**
254-TB
255
256
257***
258***
259***
249***
277***

Cable
Opening

Dimensions (in.)

max.

min.

Trade
Size

K.O.
Size

A†

.531
.585
.938
1.094
1.375
1.656
1.875
2.500
3.062
3.563

.437
.455
.812
.938
1.250
1.500
1.688
2.313
2.812
3.312

j"
c"
d"
f"
1"
1b"
1d"
2"
2d"
3"

c"
d"
d"
f"
1"
1b"
1d"
2"
2d"
3"

m
O
1r
1b
1x
1g
2b
2O
3j
3m

B

C

A
1$
1c
1w
1e
1z
1k
2e
2L
2g

X
e
u
k
d
w
l
L
f
f

* U.L. Listed as a grounding means under NEC 350-5.
** U.L. Listed for armored cable only. Fitting material steel.
*** U.L. Listed for flexible metal conduit only.
†
Approximate dimension with screw at minimum height.
U.L. File No. E 23018
CSA File No. 2884
®
®

Squeeze Connectors – 90° angle

3
⁄8" and 1⁄2" sizes made in steel. Cap lifts off by
simply loosening screws part way. Only two
screws to tighten. 3⁄4" size and larger made of
malleable iron.

Cable
Opening

Dimensions (in.)

Cat.
No.

max.

min.

Trade
Size

K.O.
Size

A

266-TB*
272**
268-TB
279
270
273TB
274***
275***
276***

.656
.812
.937
1.000
1.125
1.406
1.656
1.875
2.500

.406
.688
.813
.875
1.000
1.187
1.375
1.625
2.125

c"
c"
d"
f"
f"
1"
1b"
1d"
2"

d"
d"
d"
f"
f"
1"
1b"
1d"
2"

1d
1l
1L
1m
1g
2c
3
3c
4d

B

C

1u
100
1m
2h
1f
2r
3
3j
3m

1k
–
1g
1m
1m
2k
3
4
4g

* U.L. Listed as a grounding means under NEC350-5.
** U.L. Listed for armored cable only.
*** U.L. Listed for flexible metal conduit only.
U.L. File No. E23018
CSA File No. 2884

®
®

Squeeze Connector – 45° angle
⁄8" and 1⁄2" sizes made in steel. Cap lifts off by
simply loosening screws part way.
3

Cable
Opening

Cat.
No.

max.

min.

Trade
Size

265*
267
269

.656
.937
1.125

.406
.813
1.000

c"
d"
f"

K.O.
Size
d"
d"
f"

Dimensions (in.)
A

B

C

1w
1z
2

v
d
w

1a
1b
1l

* U.L. Listed as a grounding means under NEC350-5.
U.L. File No. E-23018
CSA File No. 2884

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A167

T&B ® Fittings

Armored Cable and Flexible Metal Conduit Fittings

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 168

T&B ® Fittings

A
Armored Cable and Flexible Metal Conduit Fittings
®
®

Two-Screw Connectors

Formed steel body with carefully round bushing. The armor gripping saddle stays open by
itself when cable is being inserted.

Cable
Opening

Dimensions (in.)

Cat.
No.

max.

min.

Trade
Size

K.O.
Size

A

B

C

3301-TB**
3312-TB

.656
.937

.250
.500

c"
d"

d"
d"

O
1p

1j
1e

1h
1c

** U.L. Listed for armored cable only.
U.L. File No. E 1383
CSA File No. 2884

Duplex Clamp Connector

A

Dimensions (in.)

Cat.
No.
B

K.O. Size

A

B

d"

1u"

1L"

291-TB

Malleable iron.
For non-metallic and armored cable.

* U.L. Listed as grounding means under NEC 350-5.
U.L. File No. E 1383
CSA File No. 2884

®
®

Adapter – EMT to Flex
Size

Cat.
No.
503TB
504
505-TB

A

Dimensions (in.)

Flex to EMT

A

B

d" - d"
f" -f"
1" - 1"

1y
1A
2o

1i
1k
2h

C
1g
2a
2e

CSA File No. 8994
U.L. File No. E-23018
C
(MAX)

B
®

TITE-BITE Connector design holds flexible
metal cable firmly in place with a single screw
rather than two screws.

A168

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 169

A
®
®

Combination Coupling

A
C

Cat.
No.
449-TB*

Size

Dimensions (in.)

Flex to EMT

A

B

C

c" - d"

1y

1X

n

B

A one piece fitting that couples 3⁄8" flexible
metal conduit to 1⁄2" electrical metallic tubing
(EMT).

* U.L. Listed as a grounding means under NEC 350-5.
Cable opening: max. .656, min. .250
U.L. File No. E-23018
CSA File No. 2884

®

Anti-Short Bushing

Anti-short bushings are made of smooth plastic, and designed to protect conductor insulation from rough edges of armored cable and
flexible metal conduit.

Cat.
No.

Size

390
391
392
393
394

14-2, 14-3, 12-2
14-4, 12-3, 6-1, and 4-1
12-4, 10-2, 10-3 and 2-1
10-4, 8-2, 8-3, and 1-1
8-4, 6-2, 6-3, 4-2, 4-3, and 6-4

Colorized
Temperature Rating: 240°F
CSA File No. 589
U.L. not applicable.
®

Strap
Elongated bolt hole makes alignment easy,
even when holes in mounting surface are off
center. Snap on features hold strap in place.

Cat.
No.

Size
c" Flex

65-TB

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A169

T&B ® Fittings

Armored Cable and Flexible Metal Conduit Fittings

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 170

T&B ® Fittings

A
Non-Metallic Sheathed Cable Fittings
Non-Metallic Sheathed Cable
Ref. NEC Article 336
Code defines Non-Metallic Sheathed
Cable as, “A factory assembly of two
or more insulated conductors having
an outer sheath of moisture resistant,
flame retardant, non-metallic material.”
Non-metallic sheathed cable is constructed of insulated conductors (14 to
2 AWG Copper or 12 to 2 AWG
Aluminum or Copperclad Aluminum),
and an outer non-metallic sheath classified as Type NM or Type NMC.
Non-metallic sheath cable is provided with or without a bare or insulated
equipment grounding conductor. Nonmetallic sheathed cable is rated for
60°C service with voltage limitation of
600 volts.
Type NM – has flame retardant
moisture resistant sheath.
Type NMC – has flame retardant
moisture resistant, fungus resistant –
and corrosion resistant sheath.
Non-metallic sheathed cable is permitted by code to be used exposed or
concealed in one, two or multifamily
dwellings or other structures not
exceeding three floors. Use of Type NM
cable is restricted to dry locations where
as Type NMC can be used in dry, moist,
damp or corrosive environments.

Non-metallic sheath cable (both
Type NM & NMC) is not permitted to
be used as a service conductor, in
commercial garages, in hoists or cannot be embedded in cement, concrete
or aggregate. With minor exceptions
use of non-metallic sheathed cable is
also prohibited in theaters or any hazardous locations.
NEC Section 336-5 requires that cable
be secured in place by suitable means
so as not to injure the cable. Adequate
protection for cable is also required when
run is exposed, through joists or rafters,
through floors, in unfinished basements
and accessible attics.
Cable bends are limited to a minimum
of five times the diameter of the cable.
NEC 300-4(b) requires that cable be
protected from physical damage when
it passes through factory or field
punched, cut or drilled holes in metal
members. A bushing or grommet firmly
secured in place is recommended.
Portions of this section reprinted by
permission from NFPA 70-1999,
National Electrical Code®,
Copyright © 1977, National Fire
Protection Association, Boston, MA.
Please refer to the following for further
details and complete information:

1.
2.
3.

4.
5.

6.

7.

8.

NEC Article 336…Non-Metallic
Sheathed Cable (Type NM & NMC)
NEC Article 300…Wiring Methods
U.L. 719, ANSI C33.56…Safety
Standards for Non-Metallic
Sheathed Cable
U.L. 514B, Safety Standards for
Outlet Boxes and Fittings
NEMA FB-1…Standards
Publication. Fittings and Supports
for Conduit and Cable Assemblies
CEC Section 12-600…Wiring
methods (Non-Metallic Sheathed
Cable)
CSA C22.2 No. 48…Safety
Standards for Non-Metallic
Sheathed Cable
CSA C22.2 No. 18…Safety
Standards for Outlet Boxes,
Conduit Boxes and Fittings

Please Note
The excerpts and other material herein, whether relating
to the National Electrical Code, the Underwriters
Laboratories, Inc. listing, to industry practice or otherwise, is
not intended to provide all relevant information required for
use and installation. Reference to original or primary source
material and data is mandatory before any application or
use is made of the product.

A170

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 171

A
Suggested Specifications for Non-Metallic Sheathed Cable

Series 3300
Non-Metallic Sheathed Cable
and Flexible Cord Connectors
(All Plastic)

• Where non-metallic sheathed cable or
flexible cord terminates into a threaded or threadless opening, terminating
fittings used shall be approved for the
purpose by nationally recognized laboratory, inspection agency or product
evaluation organization.
• Terminating fittings shall be of malleable iron, steel, or thermoplastic construction designed to provide adequate
strain relief and positively prevent damage to jacket or conductor insulation
such as series 3300 or 3302M manufactured by Thomas & Betts.
Ferrous metal fittings shall be electro
zinc plated inside/outside including
threads and bushed with a nylon
insulated throat.

Thermoplastic material used for connector construction shall be of high
impact strength suitable for
105°C/221°F service with a U.L. flammability rating of 94V-1.
• Where non-metallic sheathed cable
passes through either factory or field
punched, cut or drilled holes in
metallic members, the cable shall be
protected by thermoplastic bushing
such as series 3210 manufactured by
Thomas & Betts. Bushing shall be
firmly secured in opening. Nylon
bushed metallic fittings such as
Thomas & Betts series 1942 may be
substituted as required.

Series 3302M
Non-Metallic Sheathed Cable
and Flexible Cord Connectors
(Steel)

Series 3210
Knockout Bushings

Series 1942
Insulated Nipples

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A171

T&B ® Fittings

Non-Metallic Sheathed Cable Fittings

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 172

T&B ® Fittings

A
Non-Metallic Sheathed Cable Fittings
Non-Metallic Sheathed Cable & Flexible Cord Connectors (Steel)
Application
• To connect non-metallic sheathed
cable and flexible cord to a box or an
enclosure.
Features
• Rugged all steel/malleable iron construction (A).
• Rounded cable clamp grip provides
superior mechanical holding power
without damaging conductor insulation or outer jacket (B).
• Clamp designed to cover body opening for a neat and safe installation
• Screws thread into clamp and not
body; screw heads are snug with
body and ends of screws do not project beyond the body (C).

3302M Series
Non-Metallic Sheathed
Cable Connector

Typical Installation

(D)

• Insulator firmly secured in place protects conductors and reduces wire
pulling effort; protects threads from
damaging during handling (D).
• Locknut designed to secure connector to a box or enclosure; will not
vibrate loose.
Standard Material
Body ...............d" thru 1" Steel; 1b" thru
2" Malleable Iron
Clamp ...........d" thru 1b" Steel; 1b" thru
2" Malleable Iron
Locknut ....................................All Steel
Insulator .........................Thermoplastic
Standard Finish
All steel and malleable iron parts –
Electro Zinc Plated & Chromate
Coated
Range

Locknut

Hub Size .......................d" thru 2" Hubs
provided with straight
pipe threads (NPS.)
Cable.............2 #14 thru 4 #4 Type NM
Cable Outside Diameter ................250"
to 1.150"

Box or
Enclosure Wall

Typical Installation
(Flexible Cord)

Listed/Certified by:
U.L. (U.L. File No: E-23017)
CSA (LR-589, LR-2884)
Conforms to:
U.L. 514B
CSA C22.2 No. 18
NFPA 70-1999 (ANSI)
NEMA FB1
Federal Standard H-28 (Threads)

(A)

(B)

Typical Installation
(NM-Sheathed Cable)

(C)

A172

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/20/03

3:06 PM

Page 173

A
®
®

Two-screw Connectors
Steel or malleable iron.
Rounded cable grip and smooth bushing protect
the cable sheath and wire insulation. Since saddle is threaded, screws do not travel or extend
beyond the connector body as it is clamped to
the cable. An extra lip on the saddle closes the
unused part of the connector opening.

Non-Insulated
Cat.
No.

Insulated
Cat.
No.

K.O.
Size

U.L. Listed & CSA Certified
for the following Single (1)
and Pairs of (2) NM & NMC Cable

U.L. Listed & CSA
Certified for the following
Service Entrance Cables

A

B

C

max.

min.

3302-TB*

3302M-TB

d"

(1) 2#14, 2#12, 2#10, 3#14,
3#12, 3#10, (2) 2#14, 2#12

2#12 thru 2#4, 3#12, 3#10

O"

1c"

1"

.590

.250

3303-TB

3303M

f"

(1) 2#8, 2#6, 3#8
(2) 2#12, 2#10, 2#8, 3#14
(1) 3#8, 3#6, 3#4

2#8 thru 2#1/0, 3#8, 3#6,
2#6 + #8 GND
2#1, 2#1/0, 3#6 thru 3#2,

1b"

1e"

1i"

.750

.530

3304

3304M

1"

(2) 2#8, 3#10

2#4 + #6 GND, 2#3 + #5
GND, 2#2 + #4 GND
3#2 thru 3#2/0, 2#1 + #3

1v"

1g"

1b"

.990

.690

(1) 3#8, 3#6, 3#4

Cable Opening

3305

3305M

1b"

(2) 2#8, 2#6, 2#4, 3#8

GND, 2#1/0 + #2 GND,
2#2/0 + #1 GND

1n"

2r"

1s"

1.320

.850

3306

3306M

1d"

(1) 3#4

3#3/0, 3#4/0, 2#3/0 + #1/0
GND, 2#4/0 + #2/0 GND

2q"

2y"

1e"

1.515

.930

3307
3308†
3309†
3310†
3311†

3307M
–
–
–
–

2"
2d"
3"
3d"
4"

Max. 1.98", Min. 1.15"
Max. 2.38", Min. 1.5"
Max. 2.88", Min. 1.75"
Max. 3.38", Min. 2.25"
Max. 3.88", Min. 2.5"

–

2A"

3j"

1C"

1.980

1.150

* U.L. Listed for use with rubber and thermoplastic flexible cords (both single and multiple cords and 2 oval cables).
Not U.L. Listed or CSA certified.
U.L. Listed for multiple cords and cables.
CSA File No. 2884
U.L. File No. E-23013 – d" – 1d"; U.L. File No. E-15170 – 2"

†

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A173

T&B ® Fittings

Non-Metallic Sheathed Cable Fittings

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 174

T&B ® Fittings

A
Non-Metallic Sheathed Cable Fittings
Non-Metallic Sheathed Cable and Flexible Cord Connectors
(All Plastic)
Application
• To connect non-metallic sheathed
cable and flexible cord to a box or an
enclosure.
3300 Series

Box or
Enclosure Wall
(C)

Cable or Cord

(B)
(A)

Features
• Design provides strain relief by partially deflecting cable (A); therefore:
(1) Connector will not damage outer
covering or jacket of cable, or
conductor insulation; designed to
give safe trouble free installation.
(2) Holding power and cable strain
relief are not effected by surface
finish of outer covering or cable
jacket.
(3) Connector provides superior
holding power far in excess of
listing agency requirements.
• Snap-in one piece design; accommodates variation in knockout dimensions, saves installation time (B).
• All high impact thermoplastic construction provides:

Typical Installation

(1) Insulated throat; conductors are
protected from abrasion.
(2) Improved dielectric strength, and
eliminates potential shorts.
(3) Corrosion resistance.
• Wide range – reduces inventories.
• Connector may be pre-installed in
box K.O., or on cable.
Standard Material
All high impact thermoplastic – U.L.
Class 94V-1 suitable for 105°C application.
Standard Finish
As Molded
Listed/Certified by:
U.L. (U.L. File No: E-23017)
CSA (Cat. #3201, 3350) for factory
installation
(LR-589, LR-2884)
Conforms to:
U.L. 514B
CSA C22.2 #18 (Where applicable)
ANSI C33.84, NFPA 70-1999 (ANSI)
Range

1. Remove sheath from end of
cable (4" or more as
required). Insert cable
through connector as shown
(Cable under button).

2. Insert button into cavity.

3. With grooved pliers, or parallel jaw type pliers (commercially available) squeeze
button into cord or wires as
far into connector body as
possible.
Note: It may be necessary to
re-adjust pliers to insure
button is properly installed.

4. Snap connector into knockout 5. To remove from knockout box 6. To remove from cable cut
connector as shown.
box. If desired this step can
depress ears.
be done prior to Step 1.

A174

Cat.
No.

Knockout
Size

3300

d"

3201 &
3350

d"

3202

f"

Cable/
Cord
Range
10-2, 12-2 & 14-2 type
NM Cable.
.125" to .300" outside
diameter cord
10-3, 12-3, 14-3, 10-2,
12-2, 14-2 Type NM
Cable; also multiple
(2) 12-2 and 14-2 Type
NM Cable; .300" to .600"
outside diameter cord
8-3 and 6-3 type NM
cables; also Multiple (2)
14-3 and 10-2 Type NM
Cable; .500" to .850"
outside diameter cord

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 175

A
T&B ® Fittings

Non-Metallic Sheathed Cable Fittings
®
®

All Plastic Connector for NM Cable and Flexible Cord
Cat.
No.

Figure 2

Cat. No. 3201 is ideal for multiple flexible
cords and cable.

A

B

C

D

E

H

For use with 10-2, 12-2 and
14-2 NM cables; 18-2 and
18-3 SJ and SJO cords and
18-2 SV, SVO, SJT and SJTO
cords, single or multiple; cord
capacity .125-.300 diameter

d"

2

1o

n

c

.880

.795

.080

j" x l"

3201

For use with 10-3, 12-3, 14-3,
10-2, 12-2, 4-2 NM cables;
multiple (2) 12-2 and 14-2 NM
cables; single and multiple
flexible cords in wire
range .300 in. to .600 in.

d"

1

1X

1

k

.880

.795

.080

y dia.

3202

For use with 8-3 and 6-3 NM
cables; (2) 14-3, 14-2, 12-2
and 10-2 NM cables; single
and multiple flexible cords in
wire range .500 in. to .850 in.

f"

1

1d

1j

k

1.100

1.005

.090

g dia.

H
Hole Size

High impact thermoplastic. U.L. 94-V1.
Features push-in design. Captive locking wedge
secures cable with single squeeze of standard
electrician’s pliers. Provides excellent insulation, strain-relief and high pull-out value.

Fig.

F
Max. Thk.
Enclosure

Dimensions (in.)

3300

H
Hole
Size

Figure 1

Size Range

K.O.
Size

U.S. Pat. 3,493,205
Temperature Rating: 105°C
CSA File Nos. 584 and 2884
U.L. File No. E-23017

Snap captive locking wedge into connector’s
cavity.

Press locking wedge into cavity which locks
onto cable.

®

Snap-In Connector for Flexible Metal Conduit
Cat.
No.

No locknut required. No special tools required.
High impact thermoplastic with steel insert.

100-TB
100BP

Dimensions (in.)
Conduit Size

K.O. Size

A

B

C

Unit
Quan.

c"
c"

d"
d"

B
B

1u
1u

1O
1O

50
250

100BP sold in multiples of unit package.
Temperature Rating: 105°C
U.L. 94-V1
CSA File No. 0589

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A175

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 176

T&B ® Fittings

A
Conduit Dimensional Data
U.L. Recommended Dimensions and Weights of Rigid Metal Conduit

Trade
Size (in.)
b
c
d
f
1
1b
1d
2
2d
3
3d
4
4d
5
6

Thds.
per in.
18
18
14
14
11d
11d
11d
11d
8
8
8
8
8
8
8

I.D.
(in.)

O.D.
(in.)

Wall
Thickness
(in.)

Min. wt. at
100' Lengths
with One
Coupling
Attached
(lbs.)

0.364
0.493
0.622
0.824
1.049
1.380
1.610
2.067
2.469
3.068
3.548
4.026
4.506
5.047
6.065

.540
.675
.840
1.050
1.315
1.660
1.900
2.375
2.875
3.500
4.000
4.500
5.000
5.563
6.625

.088
.091
.109
.113
.133
.140
.145
.154
.203
.216
.226
.237
.247
.258
.280

38.5
51.5
79.0
105.0
153.0
201.0
249.0
332.0
527.0
682.6
831.0
972.3
1150.0
1313.6
1745.3

U.L. Dimensions for Intermediate Metallic Conduit† – Type I (10 ft. lgths.)
Trade
Size (in.)
d
f
1
1b
1d
2
2d
3
3d
4

min.

max.

Wall
Thickness
(in.)

.810
1.024
1.285
1.630
1.875
2.352
2.847
3.466
3.961
4.456

.820
1.034
1.295
1.645
1.890
2.367
2.867
3.486
3.981
4.476

.070*
.075*
.085*
.085*
.090*
.095*
.130**
.130**
.130**
.130**

O.D. (in.)

* (+.015. -.000)
** (+.020. -.000)
† IMC Threads are the same as Rigid Metal Conduit Threads.

U.L. Dimensions for Intermediate Metallic Conduit – Type II (10 ft. lgths.)
Trade
Size (in.)
d
f
1
1b
1d
2
2d
3
3d
4

min.

max.

Wall
Thickness
(in.)

.825
1.035
1.300
1.645
1.885
2.360
2.850
3.475
3.975
4.475

.840
1.050
1.315
1.660
1.900
2.375
2.875
3.500
4.000
4.500

.085*
.085*
.108*
.108*
.108*
.108*
.155**
.155**
.160**
.160**

O.D. (in.)

* (+.020. -.000)
** (+.025. -.000)

A176

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 177

A
T&B ® Fittings

Conduit Dimensional Data
Knockout (sliphole) Sizes for Electrical Conduits and Connectors
Trade
Size (in.)
b
c
d
f
1
1b
1d
2
2d
3
3d
4
4d
5
6

Knockout Diameter
nom.

min.

max.

.575
.718
.875
1.109
1.375
1.734
1.984
2.469
2.969
3.594
4.125
4.641
5.109
5.719
6.813

.559
.703
.859
1.094
1.359
1.719
1.958
2.433
2.938
3.563
4.063
4.563
5.063
5.625
6.700

.605
.734
.906
1.141
1.406
1.766
2.000
2.500
3.000
3.625
4.156
4.672
5.166
5.750
6.844

Sizes b" thru 1b" are per U.L. 514.
Sizes d" thru 6" per proposed revision to NEMA Engineering Bulletin No. 71, Aug. 1976.

U.L. Recommended Dimensions and Weight of Electrical Metallic Tubing (EMT)
Trade
Size (in.)
c
d
f
1
1b
1d
2
2d
3
3d
4

O.D.
(in.)
.577 ± .005
.706 ± .005
.922 ± .005
1.163 ± .005
1.510 ± .005
1.740 ± .005
2.197 ± .005
2.875 ± .010
3.500 ± .015
4.000 ± .020
4.500 ± .020

I.D.*
(in.)

Wall
Thickness
(in.)

Min. Accept
Wt. Ft.

.493
.622
.824
1.049
1.380
1.610
2.067
2.731
3.356
3.834
4.334

.042
.042
.049
.057
.065
.065
.065
.072
.072
.083
.083

.230
.285
.435
.640
.950
1.100
1.400
2.050
2.500
3.250
3.700

(lbs.)

* Not a requirement – included for information only.

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com

A177

412031.A02 FIT 3/5

3/13/03

4:57 PM

Page 178

T&B ® Fittings

A
Conduit Dimensional Data
U.L. Recommended Diameters for Flexible Metal Conduit (Greenfield)
Trade
Size (in.)
j
c
d
f
1
1b
1d
2
2d
3
3d
4

Max.
O.D.
(in.)

O.D. (in.)

.510
.610
.920
1.105
1.380
1.630
1.950
2.450
3.060
3.560
4.060
4.560

min.

max.

.312
.375
.625
.812
1.000
1.250
1.500
2.000
3.500
3.000
3.500
4.000

.393
.645
.835
–
–
–
–
–
–
–
–
–

U.L. Recommended Diameters for Liquidtight Flexible Metal Conduit
Trade
Size (in.)
c
d
f
1
1b
1d
2
2d
3
3d
4

I.D. (in.)

O.D. (in.)

min.

max.

min.

max.

.484
.622
.820
1.041
1.380
1.575
2.020
2.480
3.070
3.500
4.000

.504
.642
.840
1.066
1.410
1.600
2.045
2.505
3.100
3.540
4.040

.690
.820
1.030
1.290
1.630
1.865
2.340
2.840
3.460
3.960
4.460

.710
.840
1.050
1.315
1.660
1.900
2.375
2.875
3.500
4.000
4.500

Diameter of Liquidtight Non-Metallic Flexible Conduit
Trade
Size (in.)
c
d
f
1
1b
1d
2

A178

I.D. (in.)

O.D. (in.)

min.

max.

min.

max.

.485
.620
.815
1.030
1.370
1.585
2.045

.505
.640
.835
1.055
1.395
1.620
2.080

.755
.910
1.150
1.415
1.800
2.045
2.605

.775
.930
1.170
1.440
1.825
2.080
2.640

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

www.tnb.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 178
Page Mode                       : UseOutlines
Page Layout                     : SinglePage
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:2f96a8be-bd74-47ae-96d5-b5799be37a6a
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Create Date                     : 2003:04:29 17:14:12Z
Modify Date                     : 2003:07:07 18:56:47-05:00
Metadata Date                   : 2003:07:07 18:56:47-05:00
Creator Tool                    : QuarkXPress. 4.11: AdobePS 8.7.2 (104)
Document ID                     : uuid:726c92d3-4eec-47aa-b2f2-9cf6d311b6f1
Format                          : application/pdf
Title                           : T&B Fittings Catalog