94543 Catalog

2014-09-27

: Pdf 94543-Catalog 94543-Catalog 785901 Batch8 unilog

Open the PDF directly: View PDF PDF.
Page Count: 83

Download94543-Catalog
Open PDF In BrowserView PDF
AC Drives & Soft Starts
Pricing Guide
8800PL9701R01/12

2012
Class 8800

Altivar 61

Altivar 312

Altistart 48

Altivar 71

E-Flex

Altivar 12

S-Flex 212

Altistart 22

Altistart 01

M-Flex

PowerGard

Altivar 32

CONTENTS
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page
AC Drives for Centrifugal Pumps and Fans
(Variable Torque Applications)
Altivar™ 212 drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Altivar 61 drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
S-Flex™ 212 enclosed drives with keypad . . . . . . . . . . . . . . . . . . . . . . 10
E-Flex™ enclosed drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
M-Flex™ enclosed drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
PowerGard™ Type CPD drives. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
AC Drives for Conveyors, Mixers, Extruders and Material Handling
(Constant Torque Applications)
Altivar 12 drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Altivar 312 drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Altivar 32 drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Altivar 71 drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
M-Flex™ enclosed drive controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
PowerGard™ Type CPD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
AC Soft Start for Reduced Voltage Control
(Variable Torque or Constant Torque Applications)
Altistart™ 01 soft start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Altistart 22 soft start. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Enclosed Altistart 22 soft start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Altistart 48 soft start. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Enclosed Altistart 48 soft start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Line Reactors and Motor Protection Output Filters. . . . . . . . . . . . . . . . . . 64
Spare Parts
Altivar 61/71 drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Altistart 48 soft start. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Altivar 58 drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Altivar 21 drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Auxiliary Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

™

Pricing Guide

AC Drives and Soft Starts
Altivar™ 212 Drives

The Altivar 212 drive is for use with three-phase asynchronous motors for variable torque pump and fan applications.
Select the Altivar 212 drive from Table 1 using the motor nameplate voltage and full load ampere ratings.
The Altivar 212 drive includes 3 logic inputs, 2 analog inputs, 1 analog output, and 2 relay outputs (with 1 NO and 1
NO/NC contacts). The Altivar 212 drive includes an integrated 4 digit, 7 segment LED display with a 7 button keypad
and includes an RJ45 Modbus port plus a four-screw terminal block for BACnet, Modbus, Metasys N2, and Apogee P1
communication protocols. LonWorks® is available in an option card.
ATV212HU15N4

Table 1:

AC Input Line
Voltage

ATV212W075N4

200/240 Vac
-15%, +10%
Three-Phase

ATV212HU30M3X
with Type 1 Conduit Kit
380/480 Vac
-15%, +10%
Three-Phase

Altivar™ 212 Selection and Pricing
Three-Phase
Motor Powera

Enclosure Rating

Continuous
Output
Current

IP 20b
Open Style Product

HP

kW

Aa

Catalog Number

1
2
3
4
5
7.5
10
15
20
25
30
40
1
2
3
4
5
7.5
10
15
20
25
30
30
40
50
60
75
100

0.75
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
0.75
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
22
30
37
45
55
75

4.6
7.5
10.6
13.7
18.7
24.2
32
46.2
61
74.8
88
117
2.2
3.7
5.1
7.2
9.1
12
16
22.5
30.5
37
43.5
43.5
58.5
79
94
116
160

ATV212H075M3X
ATV212HU15M3X
ATV212HU22M3X
ATV212HU30M3X
ATV212HU40M3X
ATV212HU55M3X
ATV212HU75M3X
ATV212HD11M3X
ATV212HD15M3X
ATV212HD18M3X
ATV212HD22M3X
ATV212HD30M3X
ATV212H075N4
ATV212HU15N4
ATV212HU22N4
ATV212HU30N4
ATV212HU40N4
ATV212HU55N4
ATV212HU75N4
ATV212HD11N4
ATV212HD15N4
ATV212HD18N4
ATV212HD22N4S
ATV212HD22N4
ATV212HD30N4
ATV212HD37N4
ATV212HD45N4
ATV212HD55N4
ATV212HD75N4

$ Price

Type 1 Conduit Kit
Purchase ATV212 and Conduit
Kit for Type 1 Installation
Catalog Number

309.00
400.00
454.00
555.00
618.00
799.00
963.00
1225.00
1532.00
1795.00
2188.00
2806.00
400.00
472.00
545.00
618.00
654.00
798.00
946.00
1145.00
1425.00
1705.00
1780.00
1856.00
2284.00
2686.00
3372.00
3883.00
4433.00

$ Price

VW3A31814
VW3A31814
VW3A31814
VW3A31815
VW3A31815
VW3A31816
VW3A31816
VW3A31817
VW3A31817
VW3A31817
VW3A9206
VW3A9208
VW3A31814
VW3A31814
VW3A31814
VW3A31815
VW3A31815
VW3A31815
VW3A31816
VW3A31816
VW3A31817
VW3A31817
VW3A31817
VW3A9206
VW3A9206
VW3A9207
VW3A9207
VW3A9208
VW3A9208

45.00
45.00
45.00
45.00
45.00
45.00
45.00
45.00
45.00
45.00
65.00
135.00
45.00
45.00
45.00
45.00
45.00
45.00
45.00
45.00
45.00
45.00
45.00
65.00
65.00
65.00
65.00
135.00
135.00

Type 12 / IP54c
Catalog Number

$ Price

—
—
—
—
—
—
—
—
—
—
—
—
ATV212W075N4
ATV212WU15N4
ATV212WU22N4
ATV212WU30N4
ATV212WU40N4
ATV212WU55N4
ATV212WU75N4
ATV212WD11N4
ATV212WD15N4
ATV212WD18N4
—
ATV212WD22N4
ATV212WD30N4
ATV212WD37N4
ATV212WD45N4
ATV212WD55N4
ATV212WD75N4

—
—
—
—
—
—
—
—
—
—
—
—
500.00
590.00
681.00
772.00
817.00
998.00
1183.00
1489.00
1853.00
2131.00
—
2412.00
2855.00
3358.00
4215.00
4853.00
5541.00

UL File E116875, CSA 2278406, Plenum rated per UL 508C for UL 1995 installations. NOM, CE
a

ATV212HD37N4
with Type 1 Conduit Kit

b
c

These horsepower, wattage and continuous ampere ratings apply to the default switching frequency and maximum 40 °C ambient. Refer to the
installation manual for derating curves as a function of switching frequency, ambient temperature, and mounting conditions.
IP20 Altivar 212 drives can be installed as UL Type 1 with an optional conduit box by following the instructions in the Installation Manual.
For ATV212W... drives with Class B EMC filter, add the letter “C” to the end of the standard catalog number and multiply $ Price by 1.3.

Table 2:

Altivar 212 Options and Accessories
Description

For Use on Drives

Catalog Number

$ Price

Altivar 212, 312, 32
Altivar 61 & 71
VW3A1101
VW3A1102
VW3A1101

VW3A1101b

115.00

VW3A1102b
VW3A1103b
VW3A1105b

55.00
35.00
35.00

VW3A1104R10c
VW3A1104R30c
VW3A1104R50c
VW3A1104R100c

35.00
35.00
35.00
35.00

VW3A8121

350.00

ATVPOT25K

69.00

User Interface Options
Remote LCD
Display Keypad

VW3A1101

8 line, 24 characters per line, plain text, 8 keys, rotary wheel, 60 °C IP54 rated

IP54 rated kit for remote mounting LCD keypad on enclosure door.
Clear plastic door for use with VW3A1102 for IP65 rating and tamper resistant.
Female / Female right angle RJ45 adaptor, to connect cable and keypad.a
Remote LCD
Keypad Mounting Remote LCD Keypad Mounting Cables —Equipped with two RJ45 connectors
1 meter length
Accessories
3 meter length
5 meter length
10 meter length
Use to copy configurations between like drives, PC Soft, or
Multi-loader
SoMove PC Software
Potentiometer
Operator, mounting collar, 2.5 kilohm, 1⁄2 watt potentiometer

VW3A1101
VW3A1101
VW3A1101
VW3A1101
Altivar 12, 212, 312
32, 61, 71, & Altistart 22
Altivar 212

Software

VW3A1101
VW3A1102
VW3A1103
VW3A1104R10

PC software configuring, monitoring and trouble shooting Altivar 212 drives.
Requires one of two cables (noted below) to connect a PC to the RJ45 Modbus
port on the drive

Altivar 212

PCSoft

Universal
Bluetooth
Interface

USB/RS485 cable: equipped with USB connector and RJ45 connector
RS 232-RS485 converter with SUB-D & RJ45 port, cable with two RJ45
connectors
Bluetooth connectivity to devices through serial RS-485, RJ45 Modbus port. For
permanent installation, to be used during commissioning, maintenance and
troubleshooting of equipment.

Altivar & Altistart

Download at
http://products.schneiderelectric.us/productsservices/products/ac-drives-andsoft-starts/
TCSMCNAM3M002Pc 52.00

Altivar 212

VW3A8106b

75.00

Altivar 12, 212, 312, 61, 71,
Altistart 22

TCSWAAC13FBd

180.00

Altivar 212

VW3A21212

375.00

Altivar 212H075M3X...U22M3X
Altivar 212H075N4...U22N4

VW3A31852

375.00

Communication Option

VW3A8121

LonWorks
Communication
Card Option

Provides a four-screw terminal block for connection to LonWorks network. Install
in place of standard control board that comes mounted in the Altivar 212 drive.
The I/O count is reduced to 3LI, 1 AI and 1 NO/NC relay

Mounting Kit
DIN Rail Mounting For installation on 35 mm wide DIN rail
Kit
a
b
c
d

Not required if using VW3A1102.
Discount Schedule for this product is CP4C.
Discount Schedule for this product is CP1G.
Discount Schedule for this product is PC41.

LonWorks Option Card
VW3A21212
© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP1Gc CP4B CP4Cb PC41d Discount
Schedule

3

Pricing Guide

AC Drives and Soft StartSoft Starts
Altivar™ 61 Drives

Altivar™ 61 Single-Phase Drives
In an application where it is necessary to use a 240 V single-phase input for a 3-phase motor, the drive must be derated;
therefore, the power listed on the drive nameplate will be higher than the power rating on the motor nameplate.
For more information on wire and line reactor sizing, refer to Altivar 61 and 71 Supplementary Ratings (30072-451-38) and
page 64 for line reactor selection and pricing.
Table 3:

Altivar 61 Selection and Pricing
With a 5% Line
Reactor

Motor
Power

Continuous
Output
Current

Without a Line Reactor
Motor
Power

Continuous
Output
Current

Input
Line
Voltage

List
Price $

a

b

4

Catalog Number
with LCD Keypad

List
Price $

List
Price $
Catalog Number
with LED
Keypad
(Non-stocked)

HP kW

A

HP

kW

—

—

—

0.5

0.37

3

ATV61H075M3a

639.00

ATV61H075M3T1

684.00

ATV61H075M3Za

544.00

—

—

—

1

0.75

4.8

ATV61HU15M3a

663.00

ATV61HU15M3T1

708.00

ATV61HU15M3Za

568.00

—

—

—

2

1.5

8

ATV61HU22M3a

764.00

ATV61HU22M3T1

809.00

ATV61HU22M3Za

669.00

—

—

—

3

2.2

11

ATV61HU30M3a

925.00

ATV61HU30M3T1

970.00

ATV61HU30M3Za

830.00

—

3

13.7

—

—

—

ATV61HU40M3a

1035.00

ATV61HU40M3T1

1080.00

ATV61HU40M3Za

940.00

17.5

—

—

—

ATV61HU55M3a

1292.00

ATV61HU55M3T1

1337.00

ATV61HU55M3Za

1197.00

ATV61HU75M3a

1586.00

ATV61HU75M3T1

1631.00

ATV61HU75M3Za

1491.00

5
4
208/
240 Vac
Single 7.5 5.5
Phase 10 7.5

A

Catalog Number
for ATV61 drive and
Type 1 conduit entry
kit shipped as
one line item. Field
installation required
(packaged as kit at
warehouse).

27.5

5

4

17.5

33

7.5

5.5

27.5

ATV61HD15M3Xab 2525.00

ATV61HD15M3XT1b 2570.00

ATV61HD15M3XZab 2430.00

—

—

—

10

7.5

33

ATV61HD18M3Xab 2943.00

ATV61HD18M3XT1b 3008.00

—

—

15

11

54

—

—

—

ATV61HD22M3Xab 3586.00

ATV61HD22M3XT1b 3651.00

—

—

20

15

66

15

11

54

ATV61HD30M3Xab 4599.00

ATV61HD30M3XT1b 4684.00

—

—

25

18

75

20

15

66

ATV61HD37M3Xab 5342.00

ATV61HD37M3XT1b 5427.00

—

—

30

22

88

25

18

75

ATV61HD45M3Xab 6326.00

ATV61HD45M3XT1b 6411.00

—

—

Option to have product treated for increased protection for dusty and corrosive environments. This product is not stocked. On 0.5 hp to 5 hp at 230 Vac
single phase, add “S337” to the end of the catalog number. On 7.5 hp to 25 hp at 230 Vac single phase, add “337” to the end of the catalog number. In both
cases multiply price by 1.2 to obtain the new price. With this option, exposed copper is tinned, circuit boards are conformal coated in critical areas and
plastics are treated to better withstand the corrosive nature of certain oils.
Product does not contain an EMC filter.

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61 Drives

Altivar™ 61 Three-Phase Drives
Table 4:

Altivar 61 Selection and Pricing
Variable Torque
Three-Phase Continuous
Output
Motor Power
Current

Input
Line
Voltage

$ Price

$ Price
Catalog Number
to have ATV61 and Type 1
conduit \entry kit shipped
as one line item.
Field installation required
(Packaged as kit at
warehouse).

$ Price

HP

kW

A

208/240 Vac
Three
Phase

1
2
3
4
5
7.5
10
15
20
25
30
40
50
60
75
100
125

0.75
1.5
2.2
3
4
5.5
7.5
11
15
18
22
30
37
45
55
75
90

4.8
8
11
13.7
17.5
27.5
33
54
66
75
88
120
144
176
221
285
359

ATV61H075M3ad
ATV61HU15M3ad
ATV61HU22M3ad
ATV61HU30M3ad
ATV61HU40M3ad
ATV61HU55M3ad
ATV61HU75M3ad
ATV61HD11M3Xabd
ATV61HD15M3Xabd
ATV61HD18M3Xabd
ATV61HD22M3Xabd
ATV61HD30M3Xabd
ATV61HD37M3Xabd
ATV61HD45M3Xabd
ATV61HD55M3Xbcd
ATV61HD75M3Xbcd
ATV61HD90M3Xbcd

639.
663.
764.
925.
1035.
1292.
1586.
2011.
2525.
2943.
3586.
4599.
5342.
6326.
7806.
9379.
11954.

ATV61H075M3T1d
ATV61HU15M3T1d
ATV61HU22M3T1d
ATV61HU30M3T1d
ATV61HU40M3T1d
ATV61HU55M3T1d
ATV61HU75M3T1d
ATV61HD11M3XT1bd
ATV61HD15M3XT1bd
ATV61HD18M3XT1bd
ATV61HD22M3XT1bd
ATV61HD30M3XT1bd
ATV61HD37M3XT1bd
ATV61HD45M3XT1bd
ATV61HD55M3XT1bd
ATV61HD75M3XT1bd
ATV61HD90M3XT1bd

684.
708.
809.
970.
1080.
1337.
1631.
2056.
2570.
3008.
3651.
4684.
5427.
6411.
8266.
9839.
12507.

ATV61H075M3Z
ATV61HU15M3Z
ATV61HU22M3Z
ATV61HU30M3Z
ATV61HU40M3Z
ATV61HU55M3Z
ATV61HU75M3Z
ATV61HD11M3XZb
ATV61HD15M3XZb
—
—
—
—
—
—
—
—

544.
568.
669.
830.
940.
1197.
1491.
1916.
2430.
—
—
—
—
—
—
—
—

400/480 Vac
Three
Phase

1
2
3
4
5
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
250
350
400
500
600
700
900

0.75
1.5
2.2
3
4
5.5
7.5
11
15
18
22
30
37
45
55
75
90
110
130
160
220
250
315
400
500
630

2.3
4.1
5.8
7.8
10.5
14.3
17.6
27.7
33
41
48
66
79
94
116
160
179
215
259
314
427
481
616
759
941
1188

ATV61H075N4ad
ATV61HU15N4ad
ATV61HU22N4ad
ATV61HU30N4ad
ATV61HU40N4ad
ATV61HU55N4ad
ATV61HU75N4ad
ATV61HD11N4ad
ATV61HD15N4ad
ATV61HD18N4ad
ATV61HD22N4ad
ATV61HD30N4ad
ATV61HD37N4ad
ATV61HD45N4ad
ATV61HD55N4ad
ATV61HD75N4ad
ATV61HD90N4cd
ATV61HC11N4cd
ATV61HC13N4cd
ATV61HC16N4cd
ATV61HC22N4cd
ATV61HC25N4cde
ATV61HC31N4ce
ATV61HC40N4ce
ATV61HC50N4ce
ATV61HC63N4ce

754.
857.
999.
1125.
1158.
1299.
1578.
1868.
2322.
2795.
3042.
3744.
4403.
5528.
6365.
7267.
7988.
9022.
10366.
11711.
13993.
16475.
23734.
31783.
44235.
63935.

ATV61H075N4T1d
ATV61HU15N4T1d
ATV61HU22N4T1d
ATV61HU30N4T1d
ATV61HU40N4T1d
ATV61HU55N4T1d
ATV61HU75N4T1d
ATV61HD11N4T1d
ATV61HD15N4T1d
ATV61HD18N4T1d
ATV61HD22N4T1d
ATV61HD30N4T1d
ATV61HD37N4T1d
ATV61HD45N4T1d
ATV61HD55N4T1d
ATV61HD75N4T1d
ATV61HD90N4T1d
ATV61HC11N4T1d
ATV61HC13N4T1d
ATV61HC16N4T1d
ATV61HC22N4T1d
ATV61HC25N4T1d
—
—
—
—

799.
902.
1044.
1170.
1203.
1344.
1623.
1913.
2367.
2840.
3107.
3809.
4468.
5563.
6500.
7402.
8448.
9575.
10939.
12299.
14581.
17079.
—
—
—
—

ATV61H075N4Z
ATV61HU15N4Z
ATV61HU22N4Z
ATV61HU30N4Z
ATV61HU40N4Z
ATV61HU55N4Z
ATV61HU75N4Z
ATV61HD11N4Z
ATV61HD15N4Z
ATV61HD18N4Z
ATV61HD22N4Z
ATV61HD30N4Z
ATV61HD37N4Z
ATV61HD45N4Z
ATV61HD55N4Z
ATV61HD75N4Z
—
—
—
—
—
—
—
—
—
—

659.
762.
904.
1030.
1063.
1204.
1483.
1773.
2227.
2700.
2947.
3649.
4308.
5433.
6270.
7172.
—
—
—
—
—
—
—
—
—
—

a

b
c
d
e
f

Catalog Number
with LCD Keypad
(Stocked)f

Catalog Number
with LED
Keypad
(Non-stocked)

Option to have product treated for increased protection for dusty and corrosive environments. This product is not stocked. On 1 hp to 10 hp at 230 Vac
3 phase and up to 100 hp at 460 V, add “S337” to the end of the catalog number. On 15 hp to 60 hp at 230 Vac 3 phase, add “337” to the end of the
catalog number. In both cases multiply price by 1.2 to obtain new price. With this option, exposed copper is tinned, circuit boards are conformal coated
in critical areas and plastics are treated to better withstand the corrosive nature of certain oils. This option is standard on 55 kW/75 hp @ 230 Vac
3 phase and higher and 90 kW/125 hp @ 460 Vac and higher.
Product does not contain an EMC filter.
Product ships with a DC choke that must be field mounted. A 5% line reactor may be purchased and installed in place of the DC choke. Add “D” to the
end of the catalog number to receive just the AC drive and multiply the listed price by 0.96 to obtain new price.
These products can be ordered with LonWorks® or BACnet communication option card shipped as one line item. Field installation required. Add “LW”
to the end of the part number to receive a LonWorks option card. Add $550 to the price. Add “BN” to the end of the part number to receive a BACnet
option card. Add $225 to the price.
These products do not contain a dynamic braking transistor. A separate transistor must be added for applications requiring dynamic braking.
When ordering replacements for Square D™ brand E-Flex™, MCC and M-Flex™ enclosed drive controllers containing the Altivar 61 drive, identify the
replacement catalog number by referring to the applicable instruction manual, the side nameplate on power converter, or using the graphic keypad (menu
1.11 identification).

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

5

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61 Drives
Altivar™ 61 Selection and Pricing (continued)
Variable Torque
Three-Phase Motor Power

Continuous Output Current

Input Line Voltage

$ Price
HP

kW

A
Catalog Number with LCD Keypad
(Stocked)

3
4
5
7.5
10
15
20
25
30
40
50
60
75
100
125
150
—
200
250
350
450
550
700
800

575/690 Vac
Three Phase

a
b
c

3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
400
500
630
800

3.9
5.8
6.1
9
11
17
22
27
32
41
52
62
77
99
125
150
180
220
290
355
420
543
675
840

1889.00
1990.00
2099.00
2380.00
2799.00
3380.00
3979.00
4790.00
5780.00
6999.00
8579.00
10379.00
12199.00
14399.00
16899.00
19179.00
20795.00
24290.00
28950.00
35950.00
46750.00
59590.00
78490.00
103390.00

Conformal coating is standard.
An AC 5% line reactor is mandatory.
These products do not contain a dynamic braking transistor. A separate transistor must be added for applications requiring dynamic braking.

Table 5:

Altivar 61 UL Type 12 / IP54 Selection and Pricing
Three-Phase Motor Power

400/480 Vac
Three-Phase
UL Type 12/IP54

6

ATV61HU30Ya
ATV61HU40Ya
ATV61HU55Ya
ATV61HU75Ya
ATV61HD11Ya
ATV61HD15Ya
ATV61HD18Ya
ATV61HD22Ya
ATV61HD30Ya
ATV61HD37Ya
ATV61HD45Ya
ATV61HD55Ya
ATV61HD75Ya
ATV61HD90Ya
ATV61HC11Yab
ATV61HC13Yab
ATV61HC16Yab
ATV61HC20Yab
ATV61HC25Yabc
ATV61HC31Yabc
ATV61HC40Yabc
ATV61HC50Yabc
ATV61HC63Yabc
ATV61HC80Yabc

Continuous
Output Current

Catalog Number

$ Price

Horsepower

kW

A

1

0.75

2.3

ATV61W075N4U

943.00

2

1.5

4.1

ATV61WU15N4U

1072.00

3

2.2

5.8

ATV61WU22N4U

1249.00

—

3

7.8

ATV61WU30N4U

1406.00

5

4

10.5

ATV61WU40N4U

1448.00

7.5

5.5

14.3

ATV61WU55N4U

1624.00

10

7.5

17.6

ATV61WU75N4U

1972.00

15

11

27.7

ATV61WD11N4U

2335.00

20

15

33

ATV61WD15N4U

2903.00

25

18

41

ATV61WD18N4U

3493.00

30

22

48

ATV61WD22N4U

3803.00

40

30

66

ATV61WD30N4U

4680.00

50

37

79

ATV61WD37N4U

5504.00

60

45

94

ATV61WD45N4U

6911.00

75

55

116

ATV61WD55N4U

7956.00

100

75

160

ATV61WD75N4U

9084.00

125

90

179

ATV61WD90N4U

9986.00

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61 and Altivar 71 Drives

2

Table 6:

3

Options—Field Installed
Description

1

For Use on Drives

Operator
Interface

LCD Keypad
Mounting Kits

115.00

Remote mounting kit: includes bezel and mounting hardware

VW3A1102

55.00

Door for use with remote mount kit for IP65 rating

VW3A1103

45.00

VW3A1104R10

35.00

Cable for remote mounting LCD graphic
keypad
RJ-45 connector on each end

3 meters

I/O Option Card

any ATV61
any ATV71

VW3A1104R30

35.00

5 meters

VW3A1104R50

35.00

10 meters

VW3A1104R100

45.00

VW3A1105

35.00

RJ-45 female—female adaptor to connect LCD keypad and cable. Not
required if using VW3A1102.
Operator, mounting collar, 2.5 kilohm, 1⁄2 watt potentiometer

Option Card Assembly

PowerSuite software on CD for PC

PowerSuite™
Software Options

USB/RS485 cord set (equipped with RJ45 socket)

Universal
Bluetooth
Interface

Bluetooth connectivity to devices through serial RS-485, RJ45 Modbus
port. For permanent installation, to be used during commissioning,
maintenance and troubleshooting of equipment.

I/O Adaptor

115 Vac logic input adaptor adapts 7 logic inputs for use with
user supplied 115 Vac signals

I/O Extension
Option Cards

Basic I/O option card—4 logic inputs, 2 logic outputs, 1 Form C relay
output, an input for PTC motor probes, a 24 Vdc output, and a 10 Vdc
output
Extended I/O option card—contains all the I/O on the Basic I/O option card
plus 2 analog inputs, 2 analog outputs, 1 pulse input

Altivar 61

ATVPOT25K

69.00

Altivar AC drives
Altistart™ 48
TeSys™ U-line

VW3A8104

150.00

TCSMCNAM3M002P

52.00

Altivar 12, 212, 312, 61, 71,
and Altistart 22

TCSWAAC13FBd

180.00

any ATV61
any ATV71

VW3A3101

195.00

VW3A3201

165.00

VW3A3202

195.00

any ATV61
any ATV71

CANopen
Adapter

This adaptor connects to the RJ-45 port and provides a 9–pin male
SUB–D connector conforming to the CANopen standard
(CIA DRP 303–1)

any ATV61
any ATV71

VW3CANA71

45.00

CANopen
Connector

9-pin female SUB–D with line terminator (can be disabled). 180º cable
outlet CAN–H, CAN–L, CAN–GND connection

any ATV61
any ATV71

Incremental
Encoder
Interface
Option Cards

VW3CANKCDF180T

45.00

with RS-422 outputs, 5 Vdc

VW3A3401

85.00

with RS-422 outputs, 15 Vdc

VW3A3402

85.00

with open collector outputs, 12 Vdc

VW3A3403

85.00

with open collector outputs, 15 Vdc

VW3A3404

85.00

VW3A3405

85.00

VW3A3406

85.00

VW3A3407

85.00

with push–pull outputs, 12 Vdc
with push–pull outputs, 15 Vdc

any ATV71

with push–pull outputs, 24 Vdc
Resolver

VW3A3408a

85.00

Universal with SinCos, SinCos Hiperface®, SinCos EnDat® or SSI output

VW3A3409a

85.00

Incremental with RS422 outputs and encoder emulation

VW3A3411a

85.00

VW3A3302

550.00

Modbus Plus card (limited availability)
Modbus / Uni-Telway™ card

VW3A3303

225.00

Modbus TCP/IP daisy chain

VW3A3310D

275.00

Interbus® S card
any ATV61
any ATV71

Profibus DP card
Profibus DPv1 card
Communication
Option Cards

Communication
Option Card

VW3A3304

550.00

VW3A3307

550.00

VW3A3307S371

550.00

DeviceNet™ card

VW3A3309

225.00

Ethernet/IP™ card

VW3A3316

275.00

FIPIO™ card (limited availability)

VW3A3311

550.00

LonWorks® card

VW3A3312

550.00

Metasys® N2 card

VW3A3313

225.00

VW3A3314

225.00

BACnet card with female sub D 9 pin connector (limited availability)

VW3A3315

225.00

BACnet card with removable 4 position screw terminal connector

VW3A3319

225.00

VW3A3521S0d

755.00

Apogee® FLN P1 card

Incremental
Encoder Interface
Option Card

$ Price

VW3A1101

1 meter
4

Catalog No.

LCD graphic keypad: IP54 rating

any ATV61

IMC Option Card

ATV IMC drive controller cardc

Controller Inside
Option Card

Programmable option card, conforms with IEC61131–3 programming
standard. (Software for this option card is available after completing training
class offered by Schneider Electric Services.)

any ATV61
any ATV71

VW3A3501b

550.00

Water Solutions
Control Card

This option card contains a variety of pre-programmed functions and
features to manage multi–pump installations.

any ATV61
any ATV71

VW3A3503b

650.00

Simple Loader

Using RJ45 port connections, the configurations of a drive can be
downloaded then uploaded to compatible drive.

ATV31, ATV61, and ATV71

VW3A8120

175.00

a
b
c
d

For use with the ATV71H...383 drive ONLY.
The drive cannot support the VW3A3503 water solutions card and the VW3A3501 controller inside option card simultaneously.
SoMachine is required to use this product.
Discount Schedule for this product is PC41.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C PC41d Discount
Schedule

7

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61 and Altivar 71 Drives
Table 6:

Options—Field Installed (continued)
Description

Fan Kit

Installation of the fan kit enables the drive to operate in higher ambient
temperatures. The fan mounts on the drive. Consult the product catalog
for more information.

For Use on Drives

Fan Kit Catalog No.

ATV61/71HD18M3X...HD22M3X,
ATV61/71HD22N4
ATV61/71HD30N4...HD37N4

VW3A9404

$ Price
135.00

VW3A9405

145.00

ATV61/71HD30M3X...HD45M3X
ATV61/71HD45N4...HD75N4

VW3A9406
VW3A9407

165.00
195.00

ATV61: Options and Accessories — Variable Torque Applications
Description

ATV58 Drive

Replaced by

Mounting Plate
Catalog No.

$ Price

Single-phase supply voltage: 200…240 V 50/60 Hz
ATV58HU09M2ZU
ATV58HU18M2ZU
ATV58HU29M2ZU
ATV58HU41M2ZU
ATV58HU72M2ZU
ATV58HU90M2ZU
ATV58HD12M2ZU

ATV61H075M3
ATV61HU15M3
ATV61HU22M3
ATV61HU30M3
ATV61HU40M3
ATV61HU55M3
ATV61HU75M3

VW3A9301
VW3A9301
VW3A9303
VW3A9303
VW3A9304
VW3A9306
VW3A9307

83.00
83.00
83.00
83.00
93.00
133.00
133.00

VW3A9302
VW3A9303
VW3A9304
VW3A9304
VW3A9306
VW3A9307
VW3A9309
VW3A9309
VW3A9310
VW3A9312
VW3A9312
VW3A9312

83.00
83.00
93.00
93.00
133.00
133.00
170.00
170.00
170.00
337.00
337.00
337.00

VW3A9302
VW3A9302
VW3A9302
VW3A9304
VW3A9305
VW3A9305
VW3A9307
not available
VW3A9308
VW3A9310
VW3A9310
VW3A9310
VW3A9312
VW3A9312
VW3A9312

83.00
83.00
83.00
93.00
93.00
93.00
133.00
—
138.00
170.00
170.00
170.00
337.00
337.00
337.00

Three-phase supply voltage: 200…240 V 50/60 Hz
ATV58HU29M2ZU
ATV58HU41M2ZU
ATV58HU54M2ZU
ATV58HU72M2ZU
ATV58HU90M2ZU
ATV58HD12M2ZU
ATV58HD16M2XZU
ATV58HD16M2XZU
ATV58HD23M2XZU
ATV58HD28M2XZU
ATV58HD33M2XZU
ATV58HD46M2XZU

ATV61HU15M3
ATV61HU22M3
ATV61HU30M3
ATV61HU40M3
ATV61HU55M3
ATV61HU75M3
ATV61HD11M3X
ATV61HD15M3X
ATV61HD18M3X
ATV61HD22M3X
ATV61HD30M3X
ATV61HD37M3X

Three-phase supply voltage: 380…480 V 50/60 Hz

Mounting
Plate Kit

Kit includes: Mechanical adaptors required
for mounting an Altivar™ 61/71 drive in the
place of an Altivar 58 or Altivar 58F drive
using the same holes.

ATV58HU18N4ZU
ATV58HU29N4ZU
ATV58HU41N4ZU
ATV58HU54N4XZU
ATV58HU72N4XZU
ATV58HU90N4XZU
ATV58HD12N4XZU
ATV58HD16N4XZU
ATV58HD23N4XZU
ATV58HD28N4XZU
ATV58HD33N4XZU
ATV58HD46N4XZU
ATV58HD54N4XZU
ATV58HD64N4XZU
ATV58HD79N4XZU

ATV61H075N4
ATV61HU15N4
ATV61HU22N4
ATV61HU40N4
ATV61HU55N4
ATV61HU75N4
ATV61HD11N4
ATV61HD15N4
ATV61HD18N4
ATV61HD22N4
ATV61HD30N4
ATV61HD37N4
ATV61HD45N4
ATV61HD55N4
ATV61HD75N4

ATV71: Options and Accessories—Constant Torque Applications
ATV58 Drive

Replaced by

Mounting Plate
Catalog No.

$ Price

Single-phase supply voltage: 200…240 V 50/60 Hz
ATV58HU09M2ZU
ATV58HU18M2ZU
ATV58HU29M2ZU
ATV58HU41M2ZU
ATV58HU72M2ZU
ATV58HU90M2ZU
ATV58HD12M2ZU

ATV71H075M3
ATV71HU15M3
ATV71HU22M3
ATV71HU30M3
ATV71HU40M3
ATV71HU55M3
ATV71HU75M3

VW3A9301
VW3A9301
VW3A9303
VW3A9303
VW3A9304
VW3A9306
VW3A9307

83.00
83.00
83.00
83.00
93.00
133.00
133.00

VW3A9302
VW3A9303
VW3A9304
VW3A9304
VW3A9306
VW3A9307
VW3A9309
VW3A9309
VW3A9312
VW3A9312
VW3A9312

83.00
83.00
93.00
93.00
133.00
133.00
170.00
170.00
337.00
337.00
337.00

VW3A9302
VW3A9302
VW3A9302
VW3A9304
VW3A9304
VW3A9305
VW3A9306
VW3A9307
VW3A9308
VW3A9309
VW3A9310
VW3A9310
VW3A9312
VW3A9312
VW3A9312

83.00
83.00
83.00
93.00
93.00
93.00
133.00
133.00
138.00
170.00
170.00
170.00
337.00
337.00
337.00

Three-phase supply voltage: 200…240 V 50/60 Hz
ATV58HU29M2ZU
ATV58HU41M2ZU
ATV58HU54M2ZU
ATV58HU72M2ZU
ATV58HU90M2ZU
ATV58HD12M2ZU
ATV58HD16M2XZU
ATV58HD23M2XZU
ATV58HD28M2XZU
ATV58HD33M2XZU
ATV58HD46M2XZU

ATV71HU15M3
ATV71HU22M3
ATV71HU30M3
ATV71HU40M3
ATV71HU55M3
ATV71HU75M3
ATV71HD11M3X
ATV71HD15M3X
ATV71HD18M3X
ATV71HD22M3X
ATV71HD30M3X

Three-phase supply voltage: 380…480 V 50/60 Hz
ATV58HU18N4ZU
ATV58HU29N4ZU
ATV58HU41N4ZU
ATV58HU54N4ZU
ATV58HU72N4ZU
ATV58HU90N4ZU
ATV58HD12N4ZU
ATV58HD16N4ZU
ATV58HD23N4ZU
ATV58HD28N4ZU
ATV58HD33N4ZU
ATV58HD46N4ZU
ATV58HD54N4ZU
ATV58HD64N4ZU
ATV58HD79N4ZU

8

CP4C

Discount
Schedule

ATV71H075N4
ATV71HU15N4
ATV71HU22N4
ATV71HU30N4
ATV71HU40N4
ATV71HU55N4
ATV71HU75N4
ATV71HD11N4
ATV71HD15N4
ATV71HD18N4
ATV71HD22N4
ATV71HD30N4
ATV71HD37N4
ATV71HD45N4
ATV71HD55N4

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61 and Altivar 71 Drives

Table 6:
3

Options—Field Installed (continued)
Description

1

For Use on Drives

3
1

4

2

6

5

Flange Kit VW3A9506
Flange Kit

Kit includes:
a metal frame, seals, mounting hardware, and a
bracket to mount the fan kit so the fan can be
accessed from the front of the drive template.
Kit used to mount the heatsink of the drive
outside of an enclosure.

Type 1
Conduit Kit

Kit includes:
a metal box with conduit knockouts.
The kit provides conduit landing when wall
mounting the drive.

ATV61/71H037M3...HU15M3
ATV61/71H075N4...HU22N4
ATV61/71HU22M3...HU40M3
ATV61/71HU30N4...HU40N4
ATV61/71HU55M3
ATV61/71HU55N4, HU75N4
ATV61/71HU75M3
ATV61/71HD11N4
ATV61/71HD11M3X..HD15M3X
ATV61/71HD15N4, HD18N4
ATV61/71HD18M3X..HD22M3X
ATV61/71HD22N4, ATV61/71HU30Y...HD30Y
ATV61/71HD30N4, HD37N4
ATV61/71HD30M3X..HD45M3X
ATV61/71HD45N4...HD75N4, ATV61/71HD37Y...HD90Y
ATV61HD55M3X...HD75M3X
ATV61HD90N4...HC11N4
ATV71HD55M3X, ATV71HD90N4
ATV61HD90M3X, ATV61HC13N4
ATV71HD75M3X, ATV71HC11N4
ATV61HC16N4, ATV61HC20Y, ATV61/71HC11Y...HC16Y,
ATV71HC13N4
ATV61HC22N4, ATV71HC16N4
ATV61HC25N4…HC31N4
ATV61HC40Y
ATV61/71HC25Y, HC31Y
ATV71HC20N4...HC28N4
ATV71HC20Y
ATV61HC25N4…HC31N4 with VW3A7101 braking transistor
ATV61HC40Y
ATV61/71HC25Y, HC31Y
ATV71HC20N4...HC28N4 with VW3A7101 braking transistor
ATV71HC20Y
ATV61/71H037M3...HU15M3
ATV61/71H075N4...HU22N4
ATV61/71HU22M3...HU40M3
ATV61/71HU30N4...HU40N4
ATV61/71HU55M3
ATV61/71HU55N4, HU75N4
ATV61/71HU75M3
ATV61/71HD11N4
ATV61/71HD11M3X..HD15M3X
ATV61/71HD15N4, HD18N4
ATV61/71HD18M3X..HD22M3X
ATV61/71HD22N4
ATV61/71HU30Y...HD30Y
ATV61/71HD30N4, HD37N4
ATV61/71HD30M3X..HD45M3X
ATV61/71HD45N4..HD75N4
ATV61/71HD37Y...HD90Y
ATV61HD55M3X...HD75M3X
ATV61HD90N4...HC11N4
ATV71HD55M3X, ATV71HD90N4, ATV61HC11N4
ATV61HD90M3X, ATV61HC13N4
ATV71HD75M3X, ATV71HC11N4
ATV61HC16N4, ATV71HC13N4
ATV61/71HC11Y...HC16Y
ATV61HC20Y
ATV61HC22N4, ATV71HC16N4
ATV61HC25N4...HC31N4
ATV71HC20N4...HC28N4
ATV71HC20Y
ATV61/71HC25Y, HC31Y
ATV61HC40Y
ATV61HC25N4...HC31N4 with VW3A7101 braking transistor
ATV71HC20N4...HC28N4 with VW3A7101 braking transistor
ATV71HC20Y
ATV61/71HC25Y, HC31Y
ATV61HC40Y
230 V Drive controllers

Profibus
Option Card
Cover

a

Type 1 cover for Profibus Option Card

Catalog No.

$ Price

VW3A9501

255.00

VW3A9502

279.00

VW3A9503

325.00

VW3A9504

358.00

VW3A9505

419.00

VW3A9506

438.00

VW3A9507
VW3A9508
VW3A9509

469.00
469.00
477.00

VW3A9510

500.00

VW3A9511

667.00

VW3A9512

1053.00

VW3A9513

1053.00

VW3A9514

1053.00

VW3A9515

1062.00

VW3A9201

45.00

VW3A9202

45.00

VW3A9203

45.00

VW3A9204

45.00

VW3A9205

45.00

VW3A9206

65.00

VW3A9207
VW3A9217

65.00
85.00

VW3A9208

135.00

VW3A9209

460.00

VW3A9210

553.00

VW3A9211

573.00

VW3A9212

588.00

VW3A9213

604.00

VW3A9214

604.00

VW3A9201PF

101.00

VW3A9292PF

102.00

480 V Drive controllers

ATV61H••••a

ATV71H••••a

ATV61H••••a

ATV71H••••a

075M3
U15M3
—
U22M3
U30M3
U40M3
U55M3
—
U75M3
D11M3X
D15M3X

037M3
075M3
U15M3
U22M3
U30M3
U40M3
U55M3
—
U75M3
D11M3X
D15M3X

075N4
U15N4
U22N4
U30N4
U40N4
—
U55N4
U75N4
D11N4
D15N4
D18N4

075N4
U15N4
U22N4
U30N4
U40N4
—
U55N4
U75N4
D11N4
D15N4
D18N4

VW3A9203PF

104.00

VW3A9204PF

107.00

VW3A9205PF

112.00

The symbol “•” indicates the part of the number that varies with controller size or rating.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

9

Pricing Guide

AC Drives and Soft Starts
S-Flex™ 212 Enclosed Drive Controllers

Variable Torque AC Drive—208 V, 230 V, and 460 V Ratings
Table 7:

S-Flex™ 212 Enclosed Drive Controller Selection and Pricing
Options
Output Current

Input Line
Voltage

HP

Standard
Product List
$ Price

Catalog
Number

kW
A

208 Vac
Three-phase

230 Vac
Three-phase

S-Flex 212 Enclosed
Drive Controller Type 1
Rated +14 to +140 °F
(-10 to +40 °C)
460 Vac
Three-phase

a
b
AFC

AFC

Power
Circuit W

Power
Circuit Y

MOD B07
Price $b

SFD212CG2Y
SFD212DG2Y
SFD212EG2Y
SFD212FG2Y

1402.00
1501.00
1593.00
1789.00

1048.00
1123.00
1193.00
1342.00

1584.00
1689.00
1784.00
1992.00

1480.00
1585.00
1682.00
1889.00

7.5
10
15
20
25
30
40

5.5
7.5
11
15
18.5
22
30

25.3
32.2
48.3
62.1
78.2
92
120

SFD212GG2Y
SFD212HG2Y
SFD212JG2Y
SFD212KG2Y
SFD212LG2Y
SFD212MG2Y
SFD212NG2Y

1957.00
2253.00
2758.00
3169.00
3865.00
4705.00
5920.00

1468.00
1700.00
2089.00
2389.00
2910.00
3542.00
4911.00

2177.00
2478.00
3023.00
3476.00
4240.00
5171.00
6370.00

2066.00
2378.00
2886.00
3316.00
4044.00
4950.00
6294.00

1
2
3
5

0.75
1.5
2.2
4

4.2
6.8
9.6
15.2

SFD212CG3Y
SFD212DG3Y
SFD212EG3Y
SFD212FG3Y

1402.00
1501.00
1593.00
1789.00

1048.00
1123.00
1193.00
1342.00

1584.00
1689.00
1784.00
1992.00

1480.00
1585.00
1682.00
1889.00

7.5
10
15
20
25
30
40

5.5
7.5
11
15
18.5
22
30

22
28
42
54
68
80
104

SFD212GG3Y
SFD212HG3Y
SFD212JG3Y
SFD212KG3Y
SFD212LG3Y
SFD212MG3Y
SFD212NG3Y

1957.00
2253.00
2758.00
3169.00
3865.00
4705.00
5920.00

1468.00
1700.00
2089.00
2389.00
2910.00
3542.00
4911.00

2177.00
2478.00
3023.00
3476.00
4240.00
5171.00
6370.00

2066.00
2378.00
2886.00
3316.00
4044.00
4950.00
6294.00

1
2
3
5

0.75
1.5
2.2
4

2.1
3.4
4.8
7.6

SFD212CG4Y
SFD212DG4Y
SFD212EG4Y
SFD212FG4Y

1250.00
1317.00
1419.00
1554.00

880.00
928.00
1000.00
1095.00

1314.00
1384.00
1491.00
1633.00

1289.00
1358.00
1463.00
1602.00

7.5
10
15
20
25
30
40

5.5
7.5
11
15
18.5
22
30

11
14
21
27
34
40
52

SFD212GG4Y
SFD212HG4Y
SFD212JG4Y
SFD212KG4Y
SFD212LG4Y
SFD212MG4Y
SFD212NG4Y

1690.00
1892.00
2227.00
2709.00
3229.00
3749.00
4359.00

1190.00
1333.00
1624.00
2060.00
2455.00
3037.00
3641.00

1776.00
1988.00
2361.00
2909.00
3467.00
3956.00
4600.00

1742.00
1950.00
2296.00
2864.00
3409.00
3903.00
4538.00

50
60
75
100

37
45
55
75

65
77
96
124

SFD212PG4Y
SFD212QG4Y
SFD212RG4Y
SFD212SG4Y

5347.00
6257.00
7102.00
8097.00

4545.00
5444.00
6392.00
7293.00

5643.00
6603.00
7527.00
8581.00

5567.00
6514.00
7379.00
8413.00

Miscellaneous Optionsa

Table 9:

Option Number

$ Price

A06

50.00

LonWorks® Communication Card

B06

375.00

Metasys® N2 Factory Set Up

C06

50.00

Apogee® FLN P1 Factory Set Up

D06

50.00

LCD Text Keypad

D07

250.00

Seismic Qualification

S07

215.00

Catalog Number

$ Price

Altivar 212
PCSoft Test and Commissioning Software.
For use with Microsoft Windows™ 95, 98, NT,
XP, and Vista operating systems for PCs only.
(Cable not included.)
Download from www.schneider-electric.us.

VW3A2104c

N/C

VW3A8106

75.00

USB to RJ45 Adaptor Kit
For use in connecting to a PC with a USB port TCSMCNAM3M002P

52.00

EZ-M Mounting Channel, 72 in. length

42.00

c

All S-Flex 212 Enclosed Drives are supplied with:
Altivar™ 212 power converter
Square D™ circuit breaker disconnect (Power Fuses for 460 V
version only)
UL 508C coordinated short circuit rating for 100,000 A
Adjustable Frequency Controller-Off-Bypass selector switch
Local/Remote configurable on controller
Power On red LED
Bypass Run green LED
Fire/Freezestat interlock for Adjustable Frequency Drive and
Bypass mode

CP4D

Discount
Schedule

Accessories
Description

PC Cable for Test and Commissioning
Software
Includes 3-meter (9.8 ft.) cable,
RS-485/RS-232C adaptor, and connectors

Miscellaneous Options A06, B06, C06, and D06 are mutually
exclusive. Add Misc. Option number to S-Flex 212 catalog number
when ordering communications factory installed.
b
For Modbus control, see the Instruction Manual.
Note: See the Instruction Bulletin for set up instructions.

10

MOD A07
Price $b

4.8
7.8
11
17.5

a

•
•
•
•
•
•

MOD W
Price $a

0.75
1.5
2.2
4

BACnet Factory Set Up

•
•

Line
Contactor

1
2
3
5

Description
M

Disc Switch

When ordering a unit without bypass, insert a “W” in place of the “Y” in the Catalog Number.
Options A07 Disconnect Switch and B07 Line Contactor are available only when a full voltage bypass standard “Y” product is selected. Options A07 and
B07 are mutually exclusive.

Table 8:
M

Without
Bypass

•
•
•
•
•
•
•

EZM72MC

Can be downloaded from the internet at http://products.schneiderelectric.us/products-services/products/ac-drives-and-soft-starts/.

Form C Adjustable Frequency Controller fault auxiliary contact
Modbus RJ-45 communication port
Smoke Purge Function
Bypass Run Auxiliary Contact
Drive Run Auxiliary Contact
Full Voltage Bypass Power Circuit with overload relay
120 Vac fused control power transformer

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drives and Soft Starts
E-Flex™ Enclosed Drive Controllers – Class 8839

Variable Torque AC Drive—208, 230 V, and 460 V Ratings
Output Amperes

HP

AFC

AFC

M

M

Power
Circuit W

Power
Circuit Y

Type 3R
Type 1
Drive Controller
Drive Controller
Rated -10 to 40 °C Rated -10 to 50 °C

Class

Type

8839

EFD
1

1
2
3
5
7.5
10
15
20
25
30
40
50
60
75

208 V
4.6
7.5
10.6
16.7
24.2
30.8
46.2
59.4
74.8
88
114
143
—
—

230 V
4.2
6.8
9.6
15.2
22
28
42
54
68
80
104
130
—
—

460 V
2.1
3.4
4.8
7.6
11
14
21
27
34
40
52
65
77
96

100

—

—

124

Modifications
Control Lights Misc
A07

V
2

3

4

5

6

7

8

9

Note: Standard packages are rated 100 k AIC
Table 10:

E-Flex™ Selection and Pricing
3 Enclosure Type
208/230 V

2
HP
Code
G=
Type 1

A=
Type
12K

H=
Type 3R

6 Device Type
5
W—Without
Y—Bypass
Application
460 V
4
Bypass Package
Packageg
Type
Voltage (Applied
A=
Code
H=
Rating
Type Type 3R
208/230 V 460 V 208/230 V
460 V
Code)
12K

G=
Type 1
$ Price
$ Price
C=1
155.00 1500.00
155.00 1500.00
D=2
155.00 1500.00
155.00 1500.00
E=3
155.00 1500.00
155.00 1500.00
F=5
155.00 1500.00
155.00 1500.00
G = 7.5
155.00 1700.00
155.00 1500.00
H = 10
155.00 1700.00
155.00 1700.00
J = 15
362.00 2625.00
155.00 1700.00 2 = 208 V V=Variable
K = 20 Included 362.00 2625.00 Included 155.00 1700.00 3 = 230 V
Torque
L = 25
362.00 2625.00
155.00 1700.00 4 = 460 V
M = 30
362.00 3750.00
362.00 2625.00
N = 40
362.00 3750.00
362.00 2625.00
P = 50
362.00 3750.00
516.00 2625.00
Q = 60
—
—
516.00 3750.00
R = 75
—
—
516.00 3750.00
S = 100
—
—
516.00 3750.00

7 Control Options
A07fn
B07f
C07a
D07fh
E07fh
N07
a
b
c
d
e
f
g
h
i

j

Hand-Off—Auto, Speed Pot.
Included
Hand-Off—Auto, Start-Stop, Speed Pot.
100.00
Start-Stop, Speed Pot.
75.00
Hand-Off-Comm, Speed Pot.
N/C
Hand-Off-Comm, Start-Stop, Speed Pot. 100.00
No operators; wired for remote operation -100.00

Control Option C07 (Start-Stop, Speed Potentiometer)
is not compatible with Power Circuit Y Bypass or Light
Option A08 or B08.
Light Options A08, B08 and C08 cannot be selected
together. Select only one.
Light Option B08 (Power On, Run, Fault, Bypass) is not
compatible with Power Circuit W Without Bypass.
Misc. Option B09 Line Contactor is not compatible with
Power Circuit W (Without Bypass).
Misc. Option E09 Smoke Purge (Fireman’s Override)
permits motor to run at full speed.
Hand–Off—Auto switch must be placed in off position
for AFC fault reset.
When Power Circuit Y Bypass selected, AFC–Off–
Bypass switch and Test–Normal switch is supplied.
When communication options are selected, Control
Option D07 or E07 must be selected for control.
Misc. Option C09 3–15 PSI Transducer is not
compatible with Control Options C07, D07 or E07, J09
0–10 Vdc Auto Speed Reference Option, H09 I/O
Extension Card, F09, L09, M09, O09, P09, Q09, R09
Serial Communication Cards.
Misc. Option H09 I/O Extension Card is not compatible
with C09 3–15 PSI Transducer.

$ Price
1561.00 1530.00
1561.00 1653.00
1561.00 1791.00
1766.00 1928.00
1887.00 2044.00
2183.00 2226.00
2838.00 2479.00
3621.00 2892.00
3694.00 3083.00
4635.00 3686.00
5850.00 4424.00
7316.00 5222.00
—
6604.00
—
7372.00
8908.00
—

k

l
m

n
o
p
q
r

208/230 V

$ Price
1773.00 1739.00
1773.00 1878.00
1773.00 2036.00
2007.00 2191.00
2144.00 2323.00
2480.00 2578.00
3225.00 2817.00
4115.00 3286.00
4198.00 3503.00
5267.00 4189.00
6647.00 4800.00
8314.00 5934.00
—
7505.00
—
8378.00
—
10122.00

8 Light Options
A08bn
B08bc
C08b

9 Miscellaneous Options
Mod X09
3% Line Reactor

80.00
80.00
65.00

Misc. Option J09 input programmed for 0–10 Vdc is not
compatible with Control Options C07, D07 or E07
Control Options or Misc. Option C09 3–15 PSI
Transducer.
Omit the Keypad Option D09 from Enclosure Door. User
must buy a separate device to program the controller
inside.
Serial Communication Options F09, L09, M09, O09,
P09, Q09, R09 cannot be selected together. Select only
one. Control Option D07 or E07 must be selected for
monitoring and control with Serial Communication
Options.
Light Option A08 is compatible with Control Options
A07, B07, D07 and E07.
Misc. Option S09 End Damper Control is not compatible
with Control Options D07 Hand–Off–Comm, Speed Pot.
Or E07 Hand–Off–Comm, Start–Stop, Speed Pot.
Misc. Option B09 Line Contactor is not compatible with
Type 3R Enclosure.
Option T09 service entrance rating and K09 (cUL) are
mutually exclusive. T09 only available in Type 3R
enclosures.
T09 not available on 460 V (1–7.5 hp) and 208/230 V
(1–5 hp).

A09
B09dp
C09i
D09l
E09e
F09m
H09j
J09k
K09
L09m
M09m
O09m
P09m
Q09m
R09m
S09o
T09qr
U09
V09
X09

460 V

$ Price
216.00 216.00
235.00 235.00
235.00 235.00
253.00 253.00
298.00 298.00
382.00 382.00
394.00 394.00
478.00 478.00
478.00 478.00
497.00 497.00
560.00 560.00
729.00 729.00
—
729.00
—
811.00
—
971.00

208/230 V

460 V

$ Price
50.00 50.00
50.00 50.00
60.00 50.00
70.00 50.00
70.00 60.00
90.00 70.00
120.00 78.00
168.00 90.00
195.00 120.00
195.00 120.00
252.00 168.00
364.00 195.00
—
195.00
—
252.00
—
364.00

•
•
•
•
•

•
Discount
Schedule

5% Line Reactor option
Line Contactor
3–15 PSI Transducer
Omit Keypad
Smoke Purge (Fireman’s Override)
Profibus DP
I/O Extension Card, 0–20 mA Output
Input programmed for 0–10 Vdc
cUL Listing Certification
LonWorks® Card
Modbus™ / Uni-Telway™ Card
Apogee® P1 Card
Metasys® N2 Card
Ethernet TCP/IP
BACnet Card
End Damper Control
Service entrance rating
Seismic Qualification
Ethernet/IP™ Card
3% Line Reactor option

See Above
See Above
180.00
-40.00
80.00
400.00
150.00
N/C
140.00
400.00
165.00
165.00
165.00
165.00
165.00
115.00
185.00
215.00
275.00
See Above

E-Flex devices are supplied with:

•

•
NOTE: Order part numbers by using the
Product Selectors.

CP4C

208/230 V

Mod B09
Line Contactor

9 Miscellaneous Options

Power On, Run, Fault, Auto Lights
Power On, Run, Fault, Bypass Lights
Power On, Run, Fault Lights

•

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

460 V

$ Price
173.00 173.00
188.00 188.00
188.00 188.00
202.00 202.00
238.00 238.00
306.00 306.00
315.00 315.00
382.00 382.00
382.00 382.00
398.00 398.00
448.00 448.00
583.00 583.00
—
583.00
—
649.00
—
777.00

Mod A09
5% Line Reactor

Circuit breaker as the overcurrent protective
device (OCPD) and have a coordinated short
circuit current rating of 100,000 A symmetrical.
Equivalent 3% DC choke is standard. Option A09
replaces DC choke with 5% line reactor.
Fire/Freezestats interlock locations wired to
customer terminal strip
One Form C AFC run mode contact
One Form C AFC fault contact
Circuit Breaker Disconnect
Analog Output terminals on terminal strip (A01
and COM)
Modbus and CANopen communications built into
Drive. Modbus Uni-Telway card option provides
Modbus ASCII and 4 wire RS485 functions.
Speed Potentiometer as part of keypad or
separately mounted on the enclosure door.

11

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers

General Information
M-Flex™ enclosed adjustable frequency AC drive controllers are designed for industrial, commercial and municipal
process applications, where high functionality of features is required. Each M-Flex enclosed drive offers a platform of
standard, engineered and special features to meet the most demanding application and specification requirements.
M-Flex enclosed drive controllers are low voltage products in the following ratings:
Constant torque (Heavy duty ratings—150% current limit)

•
•
•

Altivar™ 71 power converter
1 to 450 hp, 460 V
1 to 40 hp, 208/230 V

Variable torque (Light duty ratings—110% current limit)

•
•
•

Altivar 61 power converter
1 to 500 hp, 460 V
1 to 50 hp, 208/230 V

Application Data
The table below outlines typical application characteristics with load requirements and should be used as a guideline
only. This information should be confirmed by the responsible system designer for a designated installation.
Breakaway Torque

Machines
Boring
Bottling
Milling

Constant Torque
Constant Torque
Constant Horsepowera

Moderatec
Moderatec
Moderatec

Mills
Rolling
Rubber

Constant Torquea
Constant Torquea

Moderatec
Moderatec

Mixers
Chemical
Dough
Slurry

Constant Torque
Constant Torque
Constant Torque

Highb
Highb
Highb

Planers

Constant Torque

Moderatec

Plows-Conveyor

Constant Torque

Moderatec

Constant Torque
Constant Torquea

Moderatec
Moderatec

Pullers-Car

Constant Torque

Moderatec

Pumps
Centrifugal
Positive Displacement
Slurry

Variable Torque
Constant Torque
Constant Torque

Lowd
Moderatec
Highb

Roll Benders

Constant Torque

Moderatec

Sanders

Constant Torque

Lowd

Constant Torquea

Moderatec
Highb

Breakaway Torque

Agitators
Liquid
Slurry

Variable Torquea
Variable Torquea

Moderatec
Moderatec

Blowers
Centrifugal
Positive Displacement

Variable Torque
Constant Torque

Lowd
Low (Unloaded)d

Calendars

Constant Torque

Lowd

Card Machines

Constant Torque

Moderatec

Centrifuges

Constant Torque

Moderatec

Chippers

Constant Torquea

Highb

Compressors
Axial-Centrifugal
Reciprocating
Rotary

Variable Torque
Constant Torquea
Constant Torque

Lowd
Moderatec
Moderatec

Conveyors
Belt
Screw
Shaker

Constant Torque
Constant Torquea
Constant Torquea

Moderatec
Highb
Moderatec

Cranes
Bridge
Trolley
Hoist

Constant Torque
Constant Torque
Constant Torque

Moderatec
Moderatec
Moderatec

Crushers

Constant Torquea

Highb

Constant Horsepower

Moderatec

Saws

Drill Presses

Application

Presses
Printing
Punch

Elevators

Constant Torque

Moderatec

Shakers

Constant Torquea

Extruders

Constant Torque

Moderatec

Shears

Constant Torquea

Lowd

Fans-Centrifugal

Variable Torque

Lowd

Tension Drives

Constant Horsepower

Moderatec

Frames-Spinning

Constant Horsepower

Lowd

Tool Machines

Constant Horsepower

Moderatec

Grinders

Constant Horsepower

Moderatec

Constant Torque

Kiln

Walkways

Constant Torque

Lowd

Highb

Winches

Constant Torque

Moderatec

Looms

Constant Torque

Moderatec

Winders

Constant Horsepower

Moderatec

Lathes

Constant Horsepowera

Moderatec

Washers

Constant Torque

Moderatec

a
b
c
d

12

Speed-Torque
Relationship

Speed-Torque
Relationship

Application

Potential impact load.
> 150% torque.
100 to 150% torque.
< 100% torque.

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers

Product Selection
To select an M-Flex™ enclosed drive controller, identify the basic drive and optional devices by Class, Type,
Modifications (MODS, E-MODS) and Special Features as required to create the catalog number shown below. In all
cases, Q2C/Product Selectors are preferred to price enclosed drives.
Contact Seneca TAG for pricing assistance with special features if required. Features highlighted in gray within this
selection are ENGINEERED and require special handling by factory personnel in lieu of system supported features.
CLASS

8839

TYPE

MFD

N

G

4

V

W

MODS

A07, H10, E301, SPL

SERIES

A

Series Designation
A = Altivar™ 61/71
Power converter platform

Combination Device
8839 = Circuit Breaker Type

Modifications (120+ Options)
A07 = Hand-Off-Auto selector switch
with manual speed potentiometer
H10 = Seismic qualified
E301 = ANSI #61 enclosure paint
SPL = Special features (specified)

Product Code (Prefix)
MFD = M-Flex Controller

Horsepower Rating
C = 1 hp
Q = 60 hp
D = 2 hp
R = 75 hp
E = 3 hp
S = 100 hp
F = 5 hp
T = 125 hp
G = 7.5 hp U = 150 hp
H = 10 hp
W = 200 hp
J = 15 hp
X = 250 hp
K = 20 hp
Y = 300 hp
L = 25 hp
Z = 350 hp
M = 30 hp 4 = 400 hp
N = 40 hp
5 = 450 hp
P = 50 hp
6 = 500 hp

Power Circuit Type
R = Barriered Bypass – RVAT
S = Barriered Bypass – Soft Start
T = Isolation & transfer
W = Combination device (Drive only)
Y = Integrated bypass (IEC)
Z = Barriered bypass – Full Voltage
Application Type
C = Constant torque
(Heavy duty – 150% current limit)
V = Variable torque
(Light duty – 110% current limit)

Enclosure Environmental Rating
G = Type 1 general purpose
A = Type 12/12K dust/drip proof
B = Type 1 Filtered

Voltage Code
2 = 208 V, 60 Hz
3 = 230/240 V, 60 Hz
4 = 460/480 V, 60 Hz

NOTE: Type 12/12K pending UL approval of new UL 508C Section 9.6 testing requirements for insulation materials
and is subject to availability and Q2C/Product Selector support.

Standard M-Flex Features

•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

Type 12/12K dust/drip proof enclosure ratings
Circuit Breaker Disconnect
3% AC line reactor
UL listed to UL 508C Power Conversion Equipment
100,000 A symmetrical short circuit rating
Heavy duty industrial disconnect handle with lockout/tag-out
provisions
Hand-Off-Auto selector switch and manual speed
potentiometer
0–10 Vdc and 4–20 mAdc speed reference input
0–10 Vdc or x-y mAdc programmable output
Door mounted graphic display terminal
Auto Start Relay (120 Vac control)
One Form ‘C’ AFC Run mode contact
One Form ‘C’ AFC Fault contact
Remote fault condition reset in AUTO mode with transition of
auto start contact
Manual fault condition reset in OFF position of H-O-A selector
switch
Safety interlock/Run permissive wired to customer terminal
strip
Permanent wire markings
White component mounting plate

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

•
•
•
•
•

Conduit knockouts on top and bottom for wall mounted
enclosures
Removable conduit entry plates on top and bottom for floor
mount enclosures
ANSI #49 gray enclosure
Class 10 electronic overload protection
Custom wiring diagrams

Isolation/Bypass Standard Features

•
•
•
•
•
•
•

Class 20 overload protection with door mounted reset
AFC-Off-Bypass selector switch
Test-Normal selector switch
AC3 duty rated isolation and bypass contactors
(with mechanical and electrical interlocking)
Bypass and isolation contactor sequencing provides true motor
isolation
Remote automatic bypass operation using Auto Start Relay
Custom wiring diagrams

13

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers
Table 11:

Pricing – Constant Torque
Price—Power Circuits (Type 1 General Purpose Enclosures)

Constant Torque—Heavy Duty Rating (150% Current Limit)
HP
Controller Enclosure
HP
Power
Power
Power
Power
Power
Reference Ratings
Output Frame Size Circuit
Power
W:
Circuit Y:
Circuit S:
Circuit Z:
Circuit T:
Code
Current
Circuit R:
Combination IEC Integrated
Soft Start
Full Voltage
Separate
RVAT
DIsconnect
Isolation/
Isolation/
Barriered
Starter
(Drive Only)
Bypass
Bypassa
Isolation/Bypass Isolation/Transfera Isolation/Bypassa
$
Price
$ Price
$ Price
$ Price
$ Price
$ Price
208/230 V
C
D
E
F

1
2
3
5

4.6 A
7.5 A
10.6 A
16.7 A

C

4163.00
4189.00
4498.00
4891.00

4730.00
4760.00
5111.00
5218.00

N/A
N/A
N/A
N/A

5760.00
5790.00
6141.00
6248.00

4730.00
4760.00
5111.00
5218.00

N/A
N/A
N/A
N/A

G
H

7.5
10

24.2 A
30.8 A

D

5598.00
6078.00

6247.00
6906.00

N/A
N/A

7277.00
7936.00

6247.00
6906.00

N/A
N/A

J
K
L

15
20
25

46.2 A
59.4 A
74.8 A

E

6799.00
8270.00
9342.00

7725.00
10175.00
12932.00

N/A
N/A
N/A

8965.00
11415.00
14682.00

7725.00
10175.00
12932.00

N/A
N/A
N/A

M
N

30
40

88 A
114 A

F

11129.00
14379.00

14895.00
16339.00

N/A
N/A

16645.00
18799.00

14895.00
16339.00

N/A
N/A

C
D
E
F
G
H
J
K
L

1
2
3
5
7.5
10
15
20
25

2.1 A
3.4 A
4.8 A
7.6 A
11 A
14A
21 A
27 A
34 A

C

3753.00
3985.00
4343.00
4829.00
5778.00
6465.00
7053.00
8140.00
9594.00

4909.00
5120.00
5557.00
6037.00
6767.00
7333.00
8416.00
9250.00
11441.00

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

5939.00
6150.00
6587.00
7067.00
7797.00
8363.00
9656.00
10490.00
13191.00

4909.00
5120.00
5557.00
6037.00
6767.00
7333.00
8416.00
9250.00
11441.00

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

M
N
P

30
40
50

40 A
52 A
65 A

E

11228.00
13071.00
15326.00

13351.00
14854.00
17416.00

N/A
20594.00
24566.00

15101.00
17314.00
22086.00

13351.00
14854.00
17416.00

N/A
21194.00
25656.00

Q
R
S

60
75
100

77 A
96 A
124 A

F

17344.00
20130.00
24200.00

19709.00
22875.00
31540.00

27659.00
31325.00
40540.00

24379.00
27545.00
34180.00

19709.00
22875.00
31540.00

32009.00
35175.00
43840.00

460 V

a

14

T

125

156 A

H

28400.00

36050.00

46500.00

38740.00

36050.00

56250.00

U
W
X

150
200
250

180 A
240 A
302 A

I

34000.00
39200.00
46000.00

41990.00
53590.00
N/A

53790.00
66740.00
76130.00

44740.00
56430.00
64190.00

41990.00
53590.00
61230.00

62190.00
73790.00
81430.00

Y
Z
4
5

300
350
400
450

361 A
414 A
477 A
515 A

J

52000.00
59200.00
67600.00
76390.00

83800.00
94920.00
108130.00
121880.00

71560.00
80480.00
91710.00
102010.00

68450.00
77170.00
88030.00
98080.00

106150.00
114870.00
125730.00
135780.00

N/A
N/A
N/A
N/A

Factory engineered products—dimensions subject to design
modifications.

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers

Table 12:

Pricing – Variable Torque
Price—Power Circuits (Type 1 General Purpose Enclosures)

HP
Reference
Code

Variable Torque—Light Duty Ratings (110% Current Limit)
Enclosure
Power
Power
Power
Power
Power
Frame
Power
Circuit W:
Circuit Y:
Circuit S:
Circuit Z:
Circuit T:
Size
Circuit R:
Combination IEC Integrated
Soft Start
Full Voltage
Separate
RVAT
DIsconnect
Isolation/
Isolation/
Barriered
Starter
(Drive Only)
Bypass
Bypassa
Isolation/Bypass Isolation/Transfera Isolation/Bypassa
$
Price
$ Price
$ Price
$ Price
$ Price
$ Price

HP
Ratings

Controller
Output
Current

C
D
E
F

1
2
3
5

4.6 A
7.5 A
10.6 A
16.7 A

C

4068.00
4163.00
4189.00
4498.00

4623.00
4730.00
4760.00
5111.00

N/A
N/A
N/A
N/A

5653.00
5760.00
5790.00
6141.00

4623.00
4730.00
4760.00
5111.00

N/A
N/A
N/A
N/A

G
H

7.5
10

24.2 A
30.8 A

D

4891.00
5598.00

5218.00
6247.00

N/A
N/A

6248.00
7277.00

5218.00
6247.00

N/A
N/A

J
K
L

15
20
25

46.2 A
59.4 A
74.8 A

E

6078.00
6799.00
8270.00

6906.00
7725.00
10175.00

N/A
N/A
N/A

7936.00
8965.00
11415.00

6906.00
7725.00
10175.00

N/A
N/A
N/A

M
N

30
40

88 A
114 A

F

9342.00
11129.00

12932.00
14895.00

N/A
N/A

14682.00
16645.00

12932.00
14895.00

N/A
N/A

C
D
E
F
G
H
J
K
L

1
2
3
5
7.5
10
15
20
25

2.1 A
3.4 A
4.8 A
7.6 A
11 A
14 A
21 A
27 A
34 A

C

3528.00
3753.00
3985.00
4343.00
4829.00
5778.00
6465.00
7053.00
8140.00

4646.00
4909.00
5120.00
5557.00
6037.00
6767.00
7333.00
8416.00
9250.00

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

5676.00
5939.00
6150.00
6587.00
7067.00
7797.00
8363.00
9656.00
10490.00

4646.00
4909.00
5120.00
5557.00
6037.00
6767.00
7333.00
8416.00
9250.00

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

M
N
P

30
40
50

40 A
52 A
65 A

E

9594.00
11228.00
13071.00

11441.00
13351.00
14854.00

N/A
19091.00
22004. 00

13191.00
15101.00
17314.00

11441.00
13351.00
14854.00

N/A
19781.00
23094.00

Q
R
S

60
75
100

77 A
96 A
124 A

F

15326.00
17344.00
20130.00

17416.00
19709.00
22875.00

25366.00
28159.00
31875.00

22086.00
24379.00
27545.00

17416.00
19709.00
22875.00

29716.00
32009.00
35175.00

208/230 V

460 V

a

T

125

156 A

H

24200.00

31540.00

41990.00

34180.00

31540.00

51740.00

U
W
X

150
200
250

180 A
240 A
302 A

I

28400.00
34000.00
39200.00

36050.00
41990.00
N/A

47850.00
55140.00
68490.00

38740.00
44740.00
56430.00

36050.00
41990.00
53590.00

56250.00
62190.00
91290.00

Y
Z
4
5
6

300
350
400
450
500

361 A
414 A
477 A
515 A
590 A

J

46000.00
52000.00
59200.00
67600.00
76390.00

76580.00
86200.00
97270.00
111830.00
121880.00

64190.00
71560.00
80480.00
91710.00
102010.00

61230.00
68450.00
77170.00
88030.00
98080.00

98930.00
106150.00
114870.00
125730.00
162580.00

N/A
N/A
N/A
N/A
N/A

Factory engineered products – dimensions subject to design modifications.

Table 13:
Constant Torque

Type 12 & 1G Environment Adders
Variable Torque

A = Type 12
(Dust/Drip)
$ Price

B = Type 1 G
(Gasket)
$ Price

HP @ 208/230 V
1–10 hp

1–10 hp

349.00

N/A

15–40 hp

15–50 hp

749.00

N/A

HP @ 460 V
1–20 hp

1–25 hp

349.00

N/A

25–40 hp

30–50 hp

749.00

N/A

50–75 hp

60–100 hp

949.00

N/A

100–450 hp

125–500 hp

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

N/A

CP4C

557.00

Discount
Schedule

15

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers
Table 14:

Dimensions

M-Flex™ Enclosed AC Drives Class 8839 Type MFD – With or Without Options
HP/Voltage (VT)

Weights

Construction Data

Height Width Depth
(In)
(In)
(In)

lbs.

Wall or Environment Operating
Floor
Rating
Handle
Mount

C

49.00

20

14.81

175

Wall

D

63.00

25

14.81

243

Wall

E

93.87

20

20.38

170.5

F

93.87

25

20.38

249.1

Barriered C/D

93.87

20

20.38

379

Barriered E

93.87

25

20.38

512

Barriered F

93.87

30

20.38

684

Power Circuit Wa

25" Wide
Relay Section

94.58

25

20

489

125–200 hp @ 460 V

Power Circuit
Wbc

30" Wide
Relay Section

94.58

30

20

657

250–450 hp @ 460 V

Power Circuit
Wde

35" Wide
Relay Section

94.58

35

20

969

HP/Voltage (CT)

1–25 hp @ 460 V

1–20 hp @ 460 V

1–5 hp @ 208/230 V

1–5 hp @ 208/230 V

Power Circuit
Configuration

Enclosure
Size

Power Circuit W
Combination
Device or Power
25–40 hp @ 460 V
Circuit &
15–20 hp @ 208/230 V Integrated Bypass
50–75 hp @460 V

7.5–10 hp @ 208/230 V 7.5–10 hp @ 208/230 V
30–50 hp @ 460 V
15–25 hp @ 208/230 V
60–100 hp @460 V
30–50 hp @ 208/230 V

25–40 hp @ 208/230 V

1–25 hp @ 460 V

1–20 hp @ 460 V

1–10 hp @ 208/230 V

1–10 hp @ 208/230 V

60–100 hp @ 460 V

Power Circuits
Z, S, T or R
25–40 hp @ 460 V
Barriered Designs
15–20 hp @ 208/230 V
with 2
Disconnects
50–75 hp @ 460 V

30–50 hp @ 208/230 V

25–40 hp @ 208/230 V

125 hp @ 460 V

100 hp @ 460 V

30–50 hp @ 460 V
15–25 hp @ 208/230 V

150–250 hp @ 460 V
300–500 hp @ 460 V
a
b
c
d
e

Dimensions

3" Metal
Rotary

6" Metal
Rotary
Type1orType
12/12K
3" Metal
Rotary
Floor
Mount

6" Metal
Rotary

Type1orType
1G Filtered

Flange

Integrated bypass for 125 hp offered in 20" wide section adder (45" total width). Barriered bypass offered in 25" wide section adder (50" total width)—
standard product configuration
Integrated bypass for 150–200 hp offered in 20" wide section adder (50" total width). Barriered bypass offered in 25" wide section adder (55" total width)—
standard configuration
Integrated bypass for 250 hp offered in 20" wide section adder (50" total width). Barriered bypass offered in 30" wide section adder (60" total width)—
factory engineered configuration
Integrated bypass for 300–400 hp not available. Barriered bypass offered in 30" wide section adder (65" total width)—factory engineered configuration
Integrated bypass for 450–500 hp not available. Barriered bypass offered in 35" wide section adder (70" total width)—factory engineered configuration

Operator Control Device Options
Door mounted operator controls provide dedicated control for commanding operation of the power converter functions.
Select only one.
MOD

Description

$ Price

Hand-Off-Auto selector switch with manual speed potentiometera
A07

Provides a three position selector switch and manual speed potentiometer door mounted. The Hand-Off-Auto selector switch is used to select
between the AI1 and AI2 analog inputs. In the Auto position the motor may be started and stopped by a user supplied remote contact. The
speed may be adjusted by a 4–20 mAdc signal to analog input reference AI2 or the door mounted manual speed
potentiometer. The Off position will stop the motor. The Off position is also used to reset drive controller faults.

—

Hand-Off-Auto selector switch, Start/Stop push-buttons with manual speed potentiometer

B07

Provides a three-position selector switch and manual speed potentiometer door mounted. The Hand-Off-Auto selector switch is used to select
between the AI1 and AI2 analog inputs. In the Auto position the motor may be started and stopped by a user supplied remote contact. The
speed may be adjusted by a 4–20 mAdc signal to analog input reference AI2 or the door mounted manual speed
potentiometer. In the Hand position, Start/Stop push-buttons are use to start and stop the motor using a “three-wire” control strategy. The Off
position will also stop the motor. The Off position is also used to reset drive controller faults

100.00

Start/Stop push-buttons with manual speed potentiometerb
C07

Provides Start/Stop pushbuttons to start and stop the motor using a “three-wire” control strategy. The speed is adjusted by a door mounted
manual speed potentiometer. The drive disconnect is used to reset drive controller faults unless “Fault Reset” (P10) is ordered.

75.00

Start/Stop push-buttons, Forward-Reverse selector switch with manual speed potentiometerb
D07

Provides Start/Stop push-buttons to start and stop the motor using a “three-wire” control strategy. The speed is adjusted by a door mounted
manual speed potentiometer. Motor direction is controlled with a forward –reverse selector switch. The drive disconnect is used to reset drive
controller faults unless “Fault Reset” (P10) is ordered.

200.00

Hand-Off-Auto selector, Local-Remote selector switch with manual speed potentiometer
E07

Provides a three-position selector switch and manual speed potentiometer door mounted. The Hand-Off-Auto selector switch is used to select
between the AI1 and AI2 analog inputs. In the Auto position the motor may be started and stopped by a user supplied remote contact. The
speed may be adjusted by a 4–20 mAdc signal to analog input reference AI2 or the door mounted manual speed
potentiometer. The Off position will stop the motor. The Off position is also used to reset drive controller faults.

100.00

Communication-Hand-Off-Auto selector switch with manual speed potentiometerc
F07

Provides a four-position selector switch and manual speed potentiometer door mounted. The Communication-Hand-Off-Auto selector switch
is used to select between the AI1 and AI2 analog inputs. In the Auto position the motor may be started and stopped by a user supplied remote
contact. The speed may be adjusted by a 4–20 mAdc signal to analog input reference AI2 or the door mounted manual speed potentiometer.
The Off position will stop the motor. The Off position is also used to reset drive controller faults.

250.00

No Door Mounted Operators (wired for remote operation)
N07
a
b
c

16

No operators are provided on the enclosure door. The customer must provide remote mounted operator controls. Drive controllers are factory
programmed and configured for remote mounted Hand-Off-Auto operation.

Deduct
100.00

Control option defined by default.
Available only with Power Circuit W.
Provides control and monitoring capabilities when supplied with any communication card.

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers

Pilot Light Combination Options
Pilot lights are ordered in light groups and door mounted. Pilot light groups are selected with compatible control
options. Pilot lights are all 22 mm long life LED type. Select only one.
MOD

Description

$ Price

Power On, Fault, AFC Run, Auto pilot lightsa
Provides a combination of (4) pilot lights for visual indication of protective functions and circuit status; power on (red), fault (yellow), AFC run
(green) and auto (yellow).

A08

245.00

Power On, Fault, AFC Run, Bypass pilot lightsb
Provides a combination of (4) pilot lights for visual indication of protective functions and circuit status; power on (red), fault (yellow), AFC run
(green) and bypass (yellow).

B08

245.00

Power On, Fault, AFC Run pilot lights
Provides a combination of (3) pilot lights for visual indication of protective functions and circuit status; power on (red), fault (yellow) and AFC
run (green).

C08

185.00

Power On, Fault, AFC Forward, AFC Reverse pilot lightscd
Provides a combination of (4) pilot lights for visual indication of protective functions and circuit status; power on (red), fault (yellow), forward
(green) and reverse (green).

D08

245.00

Power On, Fault, AFC Run, Hand, Auto pilot lightsef
Provides a combination of (5) pilot lights for visual indication of protective functions and circuit status; power on (red), fault (yellow), AFC run
(green), hand (blue) and auto (yellow).

E08

305.00

Power On, Fault, AFC Run, Communication pilot lightsg
Provides a combination of (4) pilot lights for visual indication of protective functions and circuit status; power on (red), fault (yellow), AFC run
(green) and communication (yellow).

F08
a
b
c
d
e
f
g

245.00

Not available with C07 or D07.
Not available with Power Circuit W.
Available only with D07 or N07.
Available only with Power Circuit W.
Available only with A07, B07, E07 or N07.
Supplied with AMR relay.
Available only with F07 or N07.

Option Cards
All communication cards are provided without factory programming. Select only one.
MOD

Description

$ Price

Modbus™ Plus communication card
A09

Provides a factory installed plug-in Modbus Plus card, VW3A3302. This interface device connects to a Modbus Plus tap.

795.00

Modbus/Uni-Telway™ communication card
B09

Provides a factory installed plug-in Modbus/Uni-Telway card, VW3A3303.

476.00

Johnson Controls Metasys® N2 communication card
C09

Provides a factory installed plug-in Johnson Controls Metasys N2 card, VW3A3313.

476.00

Ethernet TCP/IP communication card
D09

Provides a factory installed plug-in Ethernet TCP/IP card, VW3A3310, with user termination to RJ45 plug-in interface connector.

476.00

LonWorks® communication card
E09

Provides a factory installed LonWorks card, VW3A3312.

795.00

DeviceNet™ communication card
F09

Provides a factory installed DeviceNet card, VW3A3309.

476.00

Profibus DP communication card
G09

Provides a factory installed Profibus DP card, VW3A3307.

795.00

I/O Extension card
H09

Provides a factory installed I/O Extension card, VW3A3202. Adds (2) analog outputs, 4 logic inputs, 2 logic outputs and 1 differential analog
input.

275.00

Siemens Apogee® FLN / P1 communication card
J09

Provides a factory installed Siemens Building Automation Apogee FLN / P1 card, VW3A3314.

476.00

BACnet communication card
K09

Provides a factory installed BACnet card, VW3A3315.

476.00

Interbus® S communication card
L09

Provides a factory installed Interbus S card, VW3A3304.

795.00

FIPIO™ communication card
M09

Provides a factory installed FIPIO card, VW3A3311 (limited availability)

795.00

R09

Ethernet/IP™ Option Card, provides a factory installed Ethernet/IP Card VW3A3316.

476.00

D09

Ethernet TCP/IP Daisy Chain Card, provides a factory installed Ethernet TCP/IP Daisy Chain Card VW3A3310D.

476.00

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

17

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers

Miscellaneous Options
Additional system supported features that provide miscellaneous product modifications.
$ Price
MOD

Description
208/230 V

460 V

5% AC line reactora

A10

Provides an integrally mounted, 5% AC line reactor factory-installed and wired between the circuit breaker
disconnect means and the power converter for harmonic mitigation.

1–3 hp

823.00

5–7.5 hp

949.00

823.00
949.00

10–15 hp

1054.00

1000.00

20 hp

1481.00

1000.00

25 hp

1481.00

1518.00

30–40 hp

1761.00

1518.00

50 hp

1938.00

1714.00

60 hp

—

1714.00

75 hp

—

1839.00

100 hp

—

2000.00

125 hp

—

2078.00

150 hp

—

2291.00

200 hp

—

3303.00

250 hp

—

3697.00

300 hp

—

3806.00

350–400 hp

—

4988.00

450–500 hp

—

5261.00

Line contactorbc
1–5 hp

120.00

120.00

7.5–10 hp

197.00

157.00

15 hp

287.00

187.00

20 hp

402.00

213.00

25–30 hp

466.00

287.00

40 hp

601.00

402.00

50 hp

868.00

60 hp
B10

a
b
c

18

A line contactor is added between the circuit breaker disconnect (or line reactor or harmonic filter when
provided) and the power converter for bypass configured Power Circuits. With the line contactor, the AFC Fault
light illuminates when the AFC-Off-Bypass selector switch is in the Off or Bypass position to indicate that the
power converter is not running. When the line contactor is open, serial communication is disabled.

466.00

—

466.00
601.00

75 hp

—

100 hp

—

868.00

125 hp

—

1065.00

150 hp

—

1275.00

200 hp

—

1750.00

250 hp

—

2150.00

300 hp

—

2750.00

350 hp

—

3250.00

400 hp

—

3680.00

450 hp

—

4185.00

500 hp

—

4695.00

All M-Flex™ enclosed drive controllers include a 3% AC line reactor as standard. The selection of A10 substitutes a 5% line reactor in place of the 3%
AC line reactor.
Available only with Power Circuit Y, unless factory engineered.
Factory engineered for 125–500 hp ratings.

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers

Miscellaneous Options (continued)
MOD

Description

$ Price

3–15 PSI transducerabc
C10

Allows the controller to follow a user supplied 3–15 PSI input.

450.00

Omit door mounted graphic display terminal
The graphic display terminal is not supplied. To alter the programming of the power converter, the user must buy a graphic display terminal
or PowerSuite™ software to program the drive controller.

D10

Deduct
100.00

Smoke purge relay
Provides a smoke purge operating mode controlled by a user-supplied 120 Vac signal wired to terminal block TB1. Smoke purge operation
is full speed bypass (when provided) or High Speed in the drive controller. This operation is designed run the motor from any operator control
setting except emergency stop or open safety interlocks

E10

225.00

Additional control power VAc
Provides additional control power VA using a larger control transformer (120 Vac) connected to terminal block TB1for customer use.
1–50 hp @ 208/230 V / 1–100 hp @ 460 V—50 VA
125–500 hp @ 460 V—50 VA

F10

290.00
380.00

CSA / cUL certification
G10

Provides a Canadian cUL (or CSA) certification when required by local code requirements.

335.00

Seismic qualified
Supplies a certification label and hardware qualified to seismic rating ICC ES AC156 acceptance criteria test protocol with an importance
factor of 1.5.

H10

425.00

Permanent wire markers (sleeve type)d
I10

Provides permanent wire sleeve type markers on control wiring.

1750.00

0–10 Vdc Auto speed reference (programming)e
Provides a controller interface for 0–10 Vdc user supplied auto speed reference signal to the AI2 input, on terminal block TB2.
The 0–10 V analog input is not isolated, but it does contain noise suppression circuitry and a programmable electronic filter.

J10

N/C

1 Additional N.O. auxiliary drive run contactc
K10

Provides 1 additional N.O. contact for drive run indication wired to TB1.

185.00

1 Additional N.C. auxiliary drive fault contactd
L10

Provides 1 additional N.C. contact for drive fault indication wired to TB1.

185.00

1 N.O. Auxiliary bypass run contactcf
M10

Provides 1 additional N.O. contact for bypass run indication wired to TB1.

185.00

1 N.O. Auxiliary auto mode contactac
O10

Provides 1 additional N.O. contact for auto mode indication wired to TB1.

185.00

AFC Fault reset push-button acg
Provides factory installed door-mounted push button to fault reset LI4 on the power converter at terminal TB2 when Hand-Off-Auto is not
supplied.

P10

100.00

Push-to-Test pilot lightsh
Q10

Provides push-to-test function on all pilot lights except Power On.

210.00

Auto transfer to bypassfi
Provides an automatic transfer (time adjustable 0.1–10 s) to bypass in the event that the drive controller faults. A selector switch is provided
inside the enclosure to enable or disable this function. Longer transfer time requirements are available by replacing the plug-in adjustable
timer.

R10

270.00

Motor elapsed time meterc
S10

Provides a dedicated non-resettable elapsed time meter to record the motor run time. Runs whenever the motor is running.

270.00

Emergency stop mushroom head push-button ac
T10

Provides door mounted maintained off emergency stop red mushroom pushbutton with turn-to-reset feature.

127.00

Motor space heater sequencing circuit (light duty)jk
U10

Provides 50 VA/120 V to terminal block TB1 for motor space heater whenever the motor is not running.

400.00

Seal water solenoidcl
V10

Provides 50 VA/120 V to terminal block TB1 for seal water solenoid whenever the motor is running.

400.00

Check valve sequencing circuit (gravity type)c
W10

Provides an automatic shutdown of the drive controller when the user supplied N.C. contact from the check valve limit switch does not open
within 5 seconds after the motor starts. The user limit switch contact connects to terminal block TB1. Circuit provides reset function with an
illuminated (blue) push-button.

520.00

ID engraved nameplates
X10
a
b
c
d
e
f
g
h
i
j
k
l

Provides an engraved laminated nameplate attached to the front door of the enclosure (engraved per user request at time of order).

100.00

Not available with C07 or D07.
Mutually exclusive with J09.
Factory engineered for 125–500 hp ratings.
Permanent wire marking is provided as standard.
Not available with C07, D07 or C10.
Available only with Power Circuits Y, S, Z, R and T.
Available only with Power Circuit W.
Not available on Fault pilot light if P10 is selected.
Not available with B07, C07 or D07.
Mutually exclusive with V10 unless F10 is also selected.
For 125–500 hp, select E217.
Exclusive with U10 unless F10 is also selected.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

19

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers

Miscellaneous Options (continued)
MOD

Description

$ Price

Harmonic filter provisionsabc
Provides fused output terminals with return terminals for connection of an externally mounted harmonic filter
(provided separately). Class J fuses are provided.
CT
Y10

a
b
c

For 125–500 hp VT units, the standard 3% line reactor is removed due to the line impedance of the
harmonic filter.

208/230 V

460 V

VT

5–10 hp

5–10 hp

740.00

740.00

15–20 hp

15–25 hp

850.00

850.00

25–40 hp

30–50 hp

960.00

50–200 hp

60–250 hp

N/A

1070.00

250–450 hp 300–500 hp

N/A

1515.00

960.00

Not available with 1–3 hp controllers.
Mutually exclusive with A10
Factory engineered for 125–500 hp

MOD

Description

$ Price

24 Vdc power supply
Z10

Provides a 24 Vdc, 300 mA power supply at terminal block TB2.

370.00

RFI/EMI suppressor
Provides radio frequency interference suppression with ferrite cores which are factory supplied on the power wires ahead of the power
converter.

410

MOD
610
a

20

Description
100k Circuit Breaker Ratinga

250.00

$ Price
2000.00

Only available: 460 V—Constant Torque 300–450 hp. 460 V—Variable Torque 300–500 hp.

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers

Engineered Features
Factory orders with engineered features (E-MOD, SPL, etc.) are subject to review by factory personnel and have
longer lead-time availability. Standard M-Flex™ enclosure dimensions may no longer apply to orders containing any
combination of engineered features. In addition, factory orders containing engineered features may carry a UL 508A
(Industrial Control Equipment) label in lieu of a UL 508C (Power Conversion Equipment) label depending on
configuration.

Control Options
The E200 series features cover control circuit option configurations for M-Flex enclosed drive controllers.
E-MOD

Description

$ Price

Door mounted meters (dedicated displays)ab
Provides a dedicated door mounted meter display, analog or digital
E201
Analog percent speed meter scaled 0 to 120% base speed.
E202
Analog percent current scaled 0 to 100% of rated output current.
E203
Digital ammeter (amperes) scaled 0 to 2 times rated output amperes.
E204
Digital speed meter (frequency) scaled 0 to 72 Hz output frequency.
E205
Digital percent speed meter scaled 0 to 120% base speed.
E206
Digital percent current scaled 0 to 100% of rated output current.

540.00
540.00
630.00
630.00
630.00
630.00

Door mounted RJ45 port
E211

Provides (1) Sixnet RJ45 door mounted 30 mm bulk head connector and internal CAT5 cabling for access via PC with PowerSuite™
software. The RJ45 (Modbus/CANopen) drive port provides customer access through the enclosure door.

325.00

Auxiliary drive run contactscde
E212

Provides (3) Form ‘C’ contacts rated 5 A @ 120 Vac wired to terminal blocks for customer use.

310.00

Auxiliary bypass run contactsfgh
E213

Provides (3) Form ‘C’ contacts rated 5 A @ 120 Vac wired to terminal blocks for customer use.

310.00

Auxiliary drive fault contactsci
E214

Provides (3) Form ‘C’ contacts rated 5 A @ 120 Vac wired to terminal blocks for customer use.

310.00

Auxiliary auto mode contactsjk
E215

Provides (3) Form ‘C’ contacts rated 5 A @ 120 Vac wired to terminal blocks for customer use.

310.00

Adjustable restart delay timer
E216

Provides an adjustable On Time Delay Relay for power up restart function, mounted and wired for AFC mode (hand or auto) mode
and/or in the bypass mode (hand/auto).

240.00

Motor space heater (heavy duty)
E217

Provides control circuit contacts, 120 Vac, 500 VA supply and fusing wired to terminals for customer use.

1000.00

Signal loss follower alarm relayl
E218

Provides (1) Form ‘C’ contact rated 5 A @ 120 Vac wired to terminal blocks for customer use. Intended for 4–20 mAdc control loop
applications where upon the loss of input signal it is desired to retain the output signal at the last input signal level. The relay provides an
alarm relay contact for signal loss alert.

360.00

Inhibit/shutdown sequence (timed operation)
E219

Provides a relay circuit operating in the fail safe mode where a remote initiating contact opens the relay, de-energizes and after a specified
time shuts the drive controller down in the AFC mode (hand or auto) and/or in the bypass mode (hand or auto).

580.00

Check valve sequence (motorized type)
E220

Provides relay circuitry sequenced from a check valve limit switch. A valve closed position limit switch will energize relays that will initiate a
remote valve operating solenoid limited to 50 VA and give a run permissive to the drive controller in the AFC mode (hand or auto) and/or in
the bypass mode (hand or auto). A valve closed position limit switch will de-energize a timer relay such that if this relay is not de-energized
within a specified time period, the drive controller will shut down in the AFC mode (hand or auto) and/or in the bypass mode (hand or auto).

710.00

Seal water solenoid—with pressure switch feedback
E221

Provides relay, which will energize a remote seal water solenoid limited to 50 VA during drive controller operation. Additionally, the remote
initiating contact will open the relay, de-energizing and after a specified time shuts the drive controller down in the AFC mode (hand or auto)
and/or in the bypass mode (hand or auto).

1220.00

Moisture detection relay circuit (without relay)m
E222

Provides 24 V or 120 V control power to a customer supplied moisture detection relay device, either electronic or electro-mechanical.
Factory provides pre-wired socket or mounting space only.

350.00

Moisture detection relay circuit (with relay options)n
Relay option: Provides 24 V or 120 V control power to a moisture detection relay device, either electronic or electro-mechanical.
The moisture detection relay is mounted and wired by the factory.
Relay and Pilot Light indication option: Provides 24 V or 120 V control power to a customer supplied moisture detection relay device, either
E223B
electronic or electro-mechanical. Includes a pilot light for discrete input(s). The customer supplied moisture detection relay is mounted and
wired by the factory.
a
Limited to one meter selection unless H09 is selected.
b
If H09 is selected, (1) additional meter can be selected.
c
One (1) Form ‘C’ contact for drive run indication is supplied as standard.
d
Available only if K10 is selected.
e
Available without K10 for 125–500 hp.
f
One (1) N.O. contact for bypass run indication is supplied as standard when bypass is provided.
g
Available only if M10 is selected.
h
Available without M10 for 125–500 hp.
i
Available only if L10 is selected.
j
One (1) N.O. contact for auto mode indication is supplied as standard when auto mod operation is provided.
k
Available only if O10 is selected.
l
Requires use of logic output LO1.
m
Customer supplies relay. Details concerning type must also be provided at time of order entry in “Engineering Notes” within Q2C.
n
Details concerning type must be provided at time of order entry in “Engineering Notes” within Q2C.
E223A

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

1220.00
1395.00

21

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers
E-MOD

Description

$ Price

Substitute Type K operators
E224

Provides Class 9001 Type K 30 mm heavy duty multi-function operators in lieu of standard 22 mm pilot devices.

410.00

Spare control relays (for customer use)
E225

150.00
each

Provides control relays mounted and unwired for customer use. Up to (3) are available.

Substitute pilot light lens color(s)a
E226

Provides the flexibility to configure lens cap colors to contract equipment designations.

—

Blown fuse indicators on control fuses
E227

Provides blown circuit fuse indicators on control circuit fuses in lieu of standard fuses.

750.00

Motor over temperature logic input
E228

Provides dedicated terminals using an external motor over temperature input (N.C. contact) factory wired and programmed.

186.00

RTD inputs (motor protection alarm)b
E229

Provides capability for accepting RTD inputs using an RTD limit alarm, factory mounted and wired. Limited to three (3) RTD inputs.

4122.00

Motor management relay optionc
Provides motor protection and metering functions using a selection of motor management relays. This relay provides protection for motor and load conditions:
overload, differential, stator temperature, high inertia loads, undercurrent, under power, jam and bearing over temperature. The motor management relay is factory
mounted and wired. Includes PT’s and CT’s.
E230A
E230B
E230C
E230D

Schneider Electric Sepam™ Series 20 motor protective relay
Schneider Electric Sepam Series 41 motor protective relay
GE Multilin® 269+ motor management relay
GE Multilin 469 motor management relay

2850.00
3975.00
13995.00
14750.00

PowerLogic™ power meter display option
Provides a Class 3020 PM800 series power module true rms meter display with basic instrumentation, demand, THD, date/time stamping, neutral current,
min/max, alarms, event and data storage factory mounted and wired.
E231A
E231B
E231C

PM820 power module
PM850 power module
PM870 power module

1400.00
1550.00
1995.00

PowerLogic circuit monitor option
Provides a Class 3020 CM3000 or CM4000 series circuit monitor display with instrumentation, 0.2% accuracy, data logging and waveform capture, factory mounted
and wired. Includes PT’s and CT’s.
E232A
E232B
E232C
E232D

CM3250 circuit monitor
CM3350 circuit monitor
CM4000T circuit monitor
CM4250 circuit monitor

2415.00
2415.00
4275.00
4275.00

Spare terminal blocks (unwired)
E234

Provides (10) spare terminal blocks 'unwired' for customer use using the Class 9080 Type G series terminals.

120.00

End damper control circuit
E235

Provides a damper control circuit to coordinate starting of the drive controller or the bypass with the position of the damper. Requires
connection to customer damper limit switch.

240.00

Emergency power off push-button
E236

Provides a shunt trip modified molded case switch or circuit breaker where a push-pull maintained mushroom head push-button energizes
the shunt trip coil and instantaneously opens to shut down power supplied to the drive controller in the AFC mode and/or bypass mode,
coasting to an uncontrolled stop.

540.00

Audible alarm horn with silencer
E238

Provides an audible alarm horn, timer to annunciate a user defined conditions with a silencer push-button, factory assembled and wired for
customer use.

625.00

Three-phase ammeter with selector switch
Provides 3 CT's with 3-position selector switch to indicate Phase A, B or C connected on the motor leads to monitor full load amps.
E239A
E239B

Monitor input full load amps
Monitor output full load amps

1575.00
1575.00

Basin high level alarm indication option
Alarm with pilot light: Provides relay circuit and pilot light indicator alarm for high level alarm limit switch via contact closure. Includes master
reset push-button and (1) Form 'C' contact for customer use.
Command to run and alarm with pilot light indication: Provides relay circuit, timer and pilot light indicator sequenced for high level alarm limit
E240B
switch via contact closure, energizing the drive controller and/or bypass to run full speed. Includes master reset push-button and (1) Form
'C' contact for customer use
a
Specify lens cap colors desired at time of order in “Engineering Notes” field within Q2C.
b
Specify RTD values at time of order entry in “Engineering Notes” within Q2C.
c
Available for 125–500 hp only.
E240A

22

CP4C

Discount
Schedule

795.00
895.00

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers

E-MOD

Description

$ Price

Basin low-level stop with pilot light indication
E241

Provides relay circuit and pilot light indicator sequenced for low level alarm limit switch via N.O./N.C.contact closure, causing the drive
controller to stop. Includes master reset push-button and (1) Form 'C' contact for customer use.

795.00

Enclosure ventilation fan shutdown
E242

Provides interlocking and timer functions of enclosure ventilation fans to shutdown during drive controller idle conditions.

795.00

High discharge pressure with pilot light indication
E243

Provides relay circuitry with pilot light indicator sequenced from a pressure switch input, causing the drive controller to stop. Includes master
reset push-button and (1) Form 'C' contact for customer use.

795.00

Low discharge pressure with pilot light indication
E244

Provides relay circuit, timer with pilot light sequenced from a pressure switch input when low discharge condition. Includes master reset
push-button and (1) Form 'C' contact for customer use.

795.00

Low seal water shutdown with pilot light indicationa
E245

Provides relay circuitry, timer with pilot light sequenced from a pressure switch input when not enough seal water is supplied. Includes
master reset push-button and (1) Form 'C' contact for customer use.

795.00

Motor over temperature shutdown with pilot lightb
E246

Provides dedicated terminals using an external motor over temperature input (Form 'C' contact) and a pilot light indicator factory wired and
programmed.

380.00

Phase failure relayc
E247

Provides a phase failure relay (Tele RM4T series) mounted and wired to indicate phase reversal, phase loss and imbalance operating
conditions.

725.00

Single test pilot light push-buttond
E248

Provides a dedicated 30 mm push-to-test button for indication of operable pilot lights.

130.00

Substitute TeSys™ 600 V relay(s)
E249
a
b
c
d

Substitutes TeSys Type NEMA® rated relays rated 600 V, 10A.

985.00

Mutually exclusive to E221.
Mutually exclusive to E228.
Available with Power Circuits Y, Z, S, T, or R only.
Must also select E224.

Enclosure & Miscellaneous Modifications
The E300 series features cover enclosure and miscellaneous option configurations for the M-Flex™ enclosed drive
controller.
E-MOD

Description

$ Price

ANSI #61 enclosure paint
E301

Provides option to configure enclosure paint to industry standard ANSI #61 light gray paint in lieu of ANSI #49 gray.

526.00

Free standing enclosurea
E302

Converts all standard wall mounted enclosure configurations to a floor mounted 90” high enclosure.

925.00

Enclosure expansionb
E303

Converts all standard wall and floor mounted enclosures up one enclosure size.

925.00

Barriered enclosure expansionc
E304

Uses Barriered enclosure for non-bypass drives controllers. Bypass space is configured with circuit breaker disconnect and handle only.

1450.00

Enclosure space heater option
E305A

Space heater only; provides a Hoffman type enclosure strip heater and thermostat to maintain internal low temperature ambient ratings.

1500.00

E305B

Space heater with storage operation provision; provides a Hoffman type enclosure strip heater and thermostat to maintain internal low
temperature ambient ratings. Includes 120 V remote source input terminals for operation during storage conditions.

1800.00

a
b
c

Available on configurations 1–20 hp CT or 1–25 hp VT only.
Available on configurations 1–50 hp CT or 1–60 hp VT only.
Available on configurations 1–75 hp CT or 1–100 hp VT only.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

23

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers

Power Options
The E400 series features cover engineered power option configurations for M-Flex™ enclosed drive controllers.
E-MOD

Description

208/230V
Rating

$ Price

460 V
Rating

$ Price

Dynamic braking resistors

E401

Provides dynamic braking resistor top mounted on the enclosure. Resistors are 10% duty cycle
constant torque (CT) applications. Overload protection for externally mounted dynamic braking
resistor is mounted inside the drive controller enclosure.

1 hp

1035.00

1–3 hp

1415.00

2–5 hp

1245.00

5 hp

1595.00

7.5 hp

1595.00

7.5 hp

1775.00

10–15 hp

2015.00

10–20 hp

2545.00

20–25 hp

2525.00

25–40 hp

2725.00

30–40 hp

3515.00

50 hp

4015.00

—

—

60–75 hp

5335.00

1 hp

1120.00

2 hp

1120.00

3 hp

1145.00

5 hp

1165.00

7.5 hp

1215.00

10 hp

1222.00

15 hp

1530.00

20 hp

1695.00

25 hp

1770.00

30 hp

1840.00

40 hp

1895.00

50–60 hp

2675.00

75 hp

3145.00

100 hp

3675.00

125 hp

5025.00

150 hp

5230.00

200 hp

5330.00

250 hp

5365.00

300 hp

5645.00

350 hp

6540.00

400 hp

6980.00

450–500 hp

7310.00

Motor protection filter

E402

Provides a factory mounted and wired dV/dt filter on the drive output for long motor lead lengths considerations in excess of
published guidelines.

NEMA® rated contactorsa

E403

a

24

Provides NEMA rated contactors for isolation and bypass configuration in lieu of the IEC rated
contactors.

1–3 hp

1725.00

1–3 hp

1152.00

5–7.5 hp

2013.00

5–10 hp

1259.00

10–15 hp

2415.00

15–20 hp

2013.00

20–25 hp

2875.00

25–30 hp

2415.00

30 hp

3450.00

40–50 hp

2875.00

40–50 hp

4830.00

60 hp

3450.00

—

—

75–100 hp

4830.00

—

—

125 hp

5290.00

—

—

150 hp

6240.00

—

—

200 hp

7610.00

—

—

250 hp

8870.00

—

—

300 hp

8980.00

—

—

350 hp

9450.00

—

—

400 hp

11280.00

—

—

450 hp

12260.00

—

—

500 hp

12580.00

Available for Barriered design configurations only; requires selection of Power Circuit S, Z, T, or R.

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drive Products
M-Flex™ Enclosed Drive Controllers

E-MOD

Description

$ Price

Transient voltage surge suppressor
E405

Provides supplementary surge protection using a Class 1310 TVSS XWF Series Transient Voltage Surge Suppressor
hard-wired and factory mounted. 100,000 peak volts of surge protection.

1885.00

E405

Note: Service connection type (Delta or Wye) must be specified in “Engineering Notes” within Q2C.
Dual motor overloads and branch short circuit protectiona

E406

Provides short circuit and overload protection for (2) motors connected to the output of the drive controller. Includes
thermal overload modules for each motor.

1–10 hp

720.00

15–25 hp

790.00

30–50 hp

880.00

60–100 hp

1250.00

125–200 hp

3650.00

Motor A or B contactor alternation schemeb

E407

Provides a contactor interlocked for the selection of one motor for load share via a selector switch or rotation timer
scheme.

1–10 hp

1310.00

15–25 hp

1950.00

30–50 hp

2450.00

60–100 hp

5520.00

125–200 hp

11450.00

250–500 hp

24950.00

Line contactor (without bypass)

E409

Provides a line contactor between the circuit breaker disconnect (or line reactor or harmonic filter where provided) and
the power converter. When the line contactor is open, serial communications is disabled.

1–10 hp

1169.00

15–25 hp

1675.00

30–50 hp

2176.00

60–100 hp

4891.00

125–200 hp

10862.00

Secondary surge arrestor
E413

Provides a secondary surge arrester Class 6671 SDSA3650 mounted and wired.

485.00

3% output reactorc
1–5 hp

E414

a
b
c

Provides a 3% rated output reactor to address long lead considerations, mounted and wired.

750.00

7.5–25 hp

850.00

30–40 hp

1450.00

50–60 hp

1650.00

75–100 hp

1750.00

125 hp

1850.00

150 hp

2050.00

200 hp

3150.00

250 hp

3450.00

300–350 hp

4350.00

400–450 hp CT /
400–500 hp VT

4850.00

The sum of the total connected motors must not exceed the drive controller FLA rating. Specify motor FLA values at time of order entry in “Engineering
Notes” within Q2C.
Specify mode of operation via “Motor A-Off-Motor B” selector switch, remote contact closure or rotation timer scheme at time of order entry in
“Engineering Notes” within Q2C.
Available for 460/480 V rated devices only.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

25

Pricing Guide

Enclosed AC Drives
PowerGard™ Series C Enclosed Drive Controllers — Class 8839

PowerGard™ Series CPD—18-Pulse Drives
Class 8839 Type CPD family of drive controllers now features the Altivar™ 61/71 platform in an integrated 18-Pulse AC
drive solution designed for the construction and industrial markets. An 18-Pulse converter design provides near linear
load performance for adjustable frequency controllers rated 40 hp and above. This product is strategically designed to
help the user comply with IEEE 519 guidelines.
Each PowerGard 18-Pulse enclosed drive offers a feature-rich platform of standard, engineered and user-configurable
options to meet the most demanding application and specification requirements with availability in the following ratings:
Constant torque (Heavy duty ratings—150% current limit)

•
•

Altivar 71 power converter platform
40 to 450 hp, 460 V

Variable torque (Normal duty ratings—110% current limit)

•
•

Altivar 61 power converter platform
50 to 500 hp, 460 V

Selection
To select a PowerGard 18-Pulse enclosed drive controller, identify the basic drive and optional devices by Class, Type,
Options (MODS, E-MODS,) and Special Features (if required) to create the catalog number as shown below. This
catalog number is used to identify the features of the product. In all cases, Q2C/Product Selectors must be used to price
enclosed drives.
CLASS

8839

TYPE

CPD

T

G

4

V

W

MODS

A07, etc.

SERIES

Series Designation
C = Altivar 61/71
Power converter platform

Combination Device
8839 = Circuit Breaker
Disconnect
Design
CPD = PowerGard
18-Pulse Controller

Modifications
(120+ Options are available)
A07 = Hand-Off-Auto selector switch with
manual speed potentiometer

Horsepower Rating
N = 40 hp W = 200 hp
P = 50 hp
X = 250 hp
Q = 60 hp Y = 300 hp
R = 75 hp Z = 350 hp
S = 100 hp 4 = 400 hp
T = 125 hp 5 = 450 hp
U = 150 hp 6 = 500 hp

Power Circuit Type
R = Barriered Bypass—RVAT
S = Barriered Bypass—Soft Start
T = Isolation & transfer
W = Combination device (Drive only)
Y = Integrated bypass (IEC)a
Z = Barriered bypass—Full Voltage
Application Type
C = Constant torque (150% current limit)
V = Variable torque (110% current limit)

Enclosure Environmental
Rating
G = Type 1 general purpose
B = Type 1 Filtered
a

C

Voltage Code
4 = 460/480 V, 60 Hz

VT 75 hp and below.

Standard PowerGard Features

•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

Circuit Breaker Disconnect
UL listed to UL 508
100,000 A symmetrical short circuit rating
Heavy duty industrial disconnect handle with lockout/tag-out
provisions
18-Pulse transformer/reactor assembly
18-Pulse bridge rectifier assembly
Altivar 61/71 power converter
120 V fused control transformer
Hand-Off-Auto selector switch and manual speed
potentiometer
Door mounted graphic display terminal
Auto Start Relay (120 V control)
One Form “C” AFC Run mode contact
One Form “C” AFC Fault contact
Remote fault condition reset in AUTO mode with transition of
auto start contact
Manual fault condition reset in OFF position of H-O-A selector
switch

•
•
•
•
•
•
•
•

Typical Isolation/Bypass Features
(when provided)

•
•
•
•
•
•
•
•

26

Safety interlock (e.g., run permissive) wired to user terminal
block TB1
Permanent wire markings
White component mounting plate
Top and bottom conduit access
ANSI #49 gray enclosure
Class 10 electronic overload protection
Optional equipment as specified
Customized wiring diagrams

Class 20 overload protection with door mounted reset
120 V fused control transformer
AFC-Off-Bypass selector switch
Test-Normal selector switch
AC3 duty rated isolation and bypass contactors (with
mechanical and electrical interlocking)
Bypass and isolation contactor sequencing provides true motor
isolation
Overload relay reset push button
Customized wiring diagrams

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

Enclosed AC Drives
PowerGard™ Series C Enclosed Drive Controllers — Class 8839

Table 15:

Selection and Pricing
Power Circuit Configurations (Type 1 General Purpose Enclosures)

Horsepower
HP @ 460 V

HP Code

Output
Current
(A)

Combination Integrated Bypass Barriered Bypass Barriered Bypass Isolation & Transfer Barriered Bypass
Drive Only
Full Voltage
Full Voltage
Soft Start
Separate Starter
RVAT
W
Y
Z
S
T
R
$ Price
$ Price
$ Price
$ Price
$ Price
$ Price

Constant Torque—Heavy Duty Ratings (150% Current Limit)
40
50
60
75
100

N
P
Q
R
S

52
65
77
96
124

53059.00
54032.00
54347.00
55685.00
65632.00

57486.00
60035.00
61224.00
63057.00
—

57935.00
61806.00
62443.00
64218.00
77960.00

65709.00
69177.00
70941.00
73407.00
86941.00

57141.00
59690.00
60879.00
62712.00
74579.00

66817.00
73835.00
75024.00
76857.00
97809.00

125
150
200
250
300

T
U
W
X
Y

156
180
240
302
361

70980.00
75730.00
79874.00
98342.00
120928.00

—
—
—
—
—

86172.00
94601.00
99689.00
119261.00
143422.00

96648.00
106561.00
113558.00
133509.00
160258.00

82848.00
91094.00
94928.00
115512.00
139501.00

106078.00
114324.00
127933.00
154267.00
182856.00

350
400
450

Z
4
5

414
477
515

129253.00
136845.00
138523.00

—
—
—

153725.00
164572.00
167986.00

173034.00
187710.00
190837.00

149574.00
159995.00
163122.00

195229.00
212550.00
237297.00

Variable Torque—Light Duty Ratings (110% Current Limit)
50
60
75
100
125

P
Q
R
S
T

65
77
96
124
156

53059.00
54032.00
54347.00
55685.00
65632.00

57486.00
60035.00
61224.00
—
—

57935.00
61806.00
62443.00
64218.00
77960.00

65709.00
69177.00
70941.00
73407.00
86941.00

57141.00
59690.00
60879.00
62712.00
74579.00

66617.00
73835.00
75024.00
76857.00
97809.00

150
200
250
300
350

U
W
X
Y
Z

180
240
302
361
414

70980.00
75730.00
79874.00
98342.00
120928.00

—
—
—
—
—

86172.00
94601.00
99689.00
119261.00
143422.00

96648.00
106561.00
113558.00
133509.00
160258.00

82848.00
91094.00
94928.00
115512.00
139501.00

106078.00
114324.00
127933.00
154267.00
182856.00

400
450
500

4
5
6

477
515
590

129253.00
136845.00
138523.00

—
—
—

153725.00
164572.00
167986.00

173034.00
187710.00
190837.00

149574.00
159995.00
163122.00

195229.00
212550.00
237297.00

Notes:
For Type 1B enclosures with fan filter option, add $550.
The listings define the available factory modifications. Modifications in gray shaded areas require order engineering support. All modifications follow specific
interoperability rules for selection and configuration. Modification selection can be validated at the time of quotation or order entry by the Q2C/Product Selector
process. Contact your nearest Schneider Electric sales office for details.
When options with an “E” and/or “SPL” prefix appear on the name plate, engineered-to-order options are provided.

Table 16:

Dimensions
PowerGard™ Series C enclosure width dimensions

HP @ 480 V

Combination
Drive only
W

Integrated Bypass
Full Voltage
Y

Barriered Bypass
Full Voltage / Separate Starter
Z or T

Barriered Bypass
Soft Start
S

Barriered Bypass
RVAT
R

Total

Extender

Total

Extender

Total

Extender

Total

Extender

Total

50 to 75
100
125
150
200

36”
36”
36”
42”
42”

—
—
20”
20”
20”

36”
36”
56”
62”
62”

20”
20”
20”
20”
20”

56”
56”
56”
62”
62”

20”
36”
36”
36”
36”

56”
72”
72”
78”
78”

42”
42”
42”
48”
48”

78”
78”
78”
90”
90”

250
300
350
400
450
500

42”
48”
48”
48”
48” or 54”
48” or 54”

20”
25”
25”
25”
36”
36”

62”
73”
73”
73”
84”
84”

20”
25”
25”
25”
36”
36”

62”
73”
73”
73”
84”
84”

42”
42”
42”
42”
48”
48”

84”
90”
90”
90”
96”
96”

54”
54”
54”
54”
54”
54”

90”
102”
102”
102”
102”
102”

Note:
All enclosures are 94.65” height and 24” depth standard switchboard enclosures.

Table 17:

Weights and Heat Loss Data
PowerGard Series C—Power Circuit W
Estimated Heat Loss

Estimated Heat Loss

Weight
lbs.

Watts Loss

BTU/Hour

40
50
60
75
100

1603
1603
1603
1603
1703

2478
2674
2838
3027
4776

8457
9126
9686
10331
16300

—
50
60
75
100

125
150
200
250
300

2070
2070
2086
2682
2682

6333
6637
7074
9582
11216

21615
22652
24144
32703
38280

350
400
450
—

2682
2682
3148
—

11684
12894
13793
—

39877
44007
47076
—

HP @ CT rating

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

HP @ VT rating

CP4C

Discount
Schedule

Weight
Watts Loss

BTU/Hour

—
1603
1603
1603
1703

—
2674
2838
3027
3756

—
9126
9686
10331
12819

125
150
200
250
300

1703
2070
2086
2086
1682

4843
6637
7074
9582
11216

16529
22652
24144
32703
38280

350
400
450
500

2682
2682
3148
3148

11684
12894
13793
14691

39877
44007
47076
50140

27

Pricing Guide

Enclosed AC Drives
PowerGard™ Series C Enclosed Drive Controllers — Class 8839

Operator Control Device Options
Door mounted operator controls provide dedicated control for commanding power converter speed and start/stop
functions. Select only one.
MOD

Description

$ Price

Hand-Off-Auto selector switch with manual speed potentiometer
Provides a three position selector switch and manual speed potentiometer door mounted. The Hand-Off-Auto selector switch is used to select
between the AI1 and AI2 analog inputs. In the Auto position the motor may be started and stopped by a user supplied remote contact. The speed
may be adjusted by a 4–20 mAdc signal to analog input reference AI2 or the door mounted manual speed potentiometer. The Off position will stop
the motor. The Off position is also used to reset drive controller faults.
Rules: Control option defined by default.
A07

—

Hand-Off-Auto selector switch, Start/Stop push-buttons with manual speed potentiometer

B07

Provides a three-position selector switch and manual speed potentiometer door mounted. The Hand-Off-Auto selector switch is used to select
between the AI1 and AI2 analog inputs. In the Auto position the motor may be started and stopped by a user supplied remote contact. The speed
may be adjusted by a 4–20 mAdc signal to analog input reference AI2 or the door mounted manual speed potentiometer. In the Hand position,
Start/Stop push-buttons are use to start and stop the motor using a “three-wire” control strategy. The Off position will also stop the motor. The Off
position is also used to reset drive controller faults.

100.00

Start/Stop push-buttons with manual speed potentiometer
Provides Start/Stop pushbuttons to start and stop the motor using a “three-wire” control strategy. The speed is adjusted by a door mounted manual
speed potentiometer. The drive disconnect is used to reset drive controller faults unless “Fault Reset” (MOD P10) is ordered.
Rules: Available only with Power Circuit W.
C07

75.00

Start/Stop push-buttons, Forward-Reverse selector switch with manual speed potentiometer
Provides Start/Stop push-buttons to start and stop the motor using a “three-wire” control strategy. The speed is adjusted by a door mounted manual
speed potentiometer. Motor direction is controlled with a forward -reverse selector switch. The drive disconnect is used to reset drive controller
faults unless “Fault Reset” (Option P10) is ordered.
Rules: Available only with Power Circuit W.
D07

200.00

Hand-Off-Auto selector, Local-Remote selector switch with manual speed potentiometer

E07

Provides a three-position selector switch and manual speed potentiometer door mounted. The Hand-Off-Auto selector switch is used to select
between the AI1 and AI2 analog inputs. In the Auto position the motor may be started and stopped by a user supplied remote contact. The speed
may be adjusted by a 4–20 mAdc signal to analog input reference AI2 or the door mounted manual speed potentiometer. The Off position will stop
the motor. The Off position is also used to reset drive controller faults. The Local-Remote switch selects whether speed control is sent by a signal
into terminal AI1 (local) or AI2 (remote) on terminal block TB2, when the Hand-Off-Auto switch is in Auto mode.

100.00

Communication-Hand-Off-Auto selector switch with manual speed potentiometer
Provides a four-position selector switch and manual speed potentiometer door mounted. The Communication-Hand-Off-Auto selector switch is
used to select between the AI1 and AI2 analog inputs. The communication position is for communication option card control of the drive controller.
In the Auto position the motor may be started and stopped by a user supplied remote contact. The speed may be adjusted by a
4–20 mAdc signal to analog input reference AI2 or the door mounted manual speed potentiometer. The Off position will stop the motor. The Off
position is also used to reset drive controller faults.
Rules: Provides control and monitoring capabilities when supplied with any communication card.
F07

250.00

No Door Mounted Operators (wired for remote operation)
N07

No operators are provided on the enclosure door. The customer must provide remote mounted operator controls. Drive controllers are factory
programmed and configured for remote mounted Hand-Off-Auto operation.

Deduct
$100.00

Pilot Light Options
Pilot lights are ordered in light groups and door mounted. Pilot light groups are selected with compatible control
options. Pilot lights are all 22 mm, long-life LED type. Select only one.
MOD

Description

$ Price

Power On, Fault, AFC Run, Auto pilot lights
a combination of (4) pilot lights for visual indication of protective functions and circuit status; power on (red), fault (yellow), AFC run (green)
A08 Provides
and auto (yellow).
Rules: Not available with C07 or D07.

245.00

Power On, Fault, AFC Run, Bypass pilot lights
Provides a combination of (4) pilot lights for visual indication of protective functions and circuit status; power on (red), fault (yellow), AFC run (green)
and bypass (yellow).
Rules: Not available with Power Circuit W.
B08

245.00

Power On, Fault, AFC Run pilot lights
C08

Provides a combination of (3) pilot lights for visual indication of protective functions and circuit status; power on (red), fault (yellow) and AFC run
(green).

185.00

Power On, Fault, AFC Forward, AFC Reverse pilot lights
a combination of (4) pilot lights for visual indication of protective functions and circuit status; power on (red), fault (yellow), forward (green)
D08 Provides
and reverse (green).
Rules: 1. Available only with D07 or N07.
2. Available only with Power Circuit W.

245.00

Power On, Fault, AFC Run, Hand, Auto pilot lights
Provides a combination of (5) pilot lights for visual indication of protective functions and circuit status; power on (red), fault (yellow), AFC run
(green), hand (blue) and auto (yellow).
Rules: 1. Available only with A07, B07, E07 or N07.
2. Supplied with AMR relay.
E08

305.00

Power On, Fault, AFC Run, Communication pilot lights
Provides a combination of (4) pilot lights for visual indication of protective functions and circuit status; power on (red), fault (yellow), AFC run (green)
and communication (yellow).
Rules: Available only with F07 or N07.
F08

28

CP4C

Discount
Schedule

245.00

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

Enclosed AC Drives
PowerGard™ Series C Enclosed Drive Controllers — Class 8839

Option Cards
All communication cards are provided without factory programming. Select only one.
MOD

Description

$ Price

Modbus™ Plus communication card
A09

Provides a factory installed plug-in Modbus Plus card, VW3A3302. This interface device connects to a Modbus Plus tap.

795.00

Modbus/Uni-Telway™ communication card
B09

Provides a factory installed plug-in Modbus/Uni-Telway card, VW3A3303.

476.00

Johnson Controls Metasys® N2 communication card
C09

Provides a factory installed plug-in Metasys N2 card, VW3A3313.

476.00

Ethernet TCP/IP communication carD
D09

Provides a factory installed plug-in Ethernet TCP/IP card, VW3A3310, with user termination to RJ45 plug-in interface connector.

476.00

LonWorks® communication card
E09

Provides a factory installed LonWorks card, VW3A3312.

795.00

DeviceNet™ communication card
F09

Provides a factory installed DeviceNet card, VW3A3309.

476.00

Profibus DP communication card
G09

Provides a factory installed Profibus DP card, VW3A3307.

795.00

I/O Extension card
H09

Provides a factory installed I/O extension card, VW3A3202. Adds (2) analog outputs, 4 logic inputs, 2 logic outputs and 1 differential analog input.

275.00

Siemens Apogee® FLN / P1 communication card
J09

Provides a factory installed Apogee P1 card, VW3A3314.

476.00

BACnet communication card
K09

Provides a factory installed BACnet card, VW3A3315.

476.00

Interbus® S communication card
L09

Provides a factory installed Interbus card, VW3A3304.

795.00

FIPIO™ communication card
M09

Provides a factory installed FIPIO card, VW3A3311 (limited availability).

795.00

Bluetooth® Modbus
P09

Provides a Bluetooth Modbus adapter, TCSWAAC13FB.

125.00

FIPIO communication card
R09

Ethernet/IP™ Option Card, Provides a factory installed Ethernet/IP Card VW3A3316

476.00

D09

Ethernet TCP/IP Daisy Chain Card, Provides a factory installed Ethernet TCP/IP Daisy Chain Card VW3A3310D

476.00

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

29

Pricing Guide

Enclosed AC Drives
PowerGard™ Series C Enclosed Drive Controllers — Class 8839

Miscellaneous Options
Pre-engineered and system supported options to provide miscellaneous product modifications.
MOD

Description

$ Price

3–15 PSI Transducer
C10

Allows the controller to follow a user supplied 3–15 PSI input.

450.00

Rules: 1. Not available with C07 or D07.
2. Mutually exclusive with J09.
Omit Door mounted graphic display terminal
D10

The graphic display terminal is not supplied. To alter the programming of the power converter, the user must buy a graphic display terminal or
PowerSuite™ software to program the drive controller.

Deduct
100.00

Smoke Purge Relay
E10

Provides a smoke purge operating mode controlled by a user-supplied 120 Vac signal wired to terminal block TB1. Smoke purge operation is full
speed bypass (when provided) or High Speed in the drive controller. This operation is designed run the motor from any operator control setting
except emergency stop or open safety interlocks.

225.00

Additional 200 VA Control Power
F10

Provides additional control power 200 VA using a larger 120 V control transformer connected to terminal block TB1 for customer use.

380.00

cUL Certification
G10

Provides a Canadian cUL certification when required by local code requirements.

335.00

Seismic Qualified
H10

Supplies a certification label and hardware qualified to seismic rating ICC ES AC156 acceptance criteria test protocol with an importance
factor of 1.5.

425.00

Permanent Wire Marker (Sleeve Type)
I10

Provides permanent wire sleeve type markers on control wiring.

1750.00

Note: Permanent wire markings are provided as standard.
Input programmed for 0–10 Vdc AI2 input
J10

Provides programming for 0–10 Vdc user supplied auto speed reference signal to the AI2 input, on terminal block TB2. The 0–10 Vdc analog input
is not isolated, but it does contain noise suppression circuitry and a programmable electronic filter. using a 0–10 V / 4–20 mA converter
(P/n# 31158-297-50). Source impedance: Z=40k Ω .

—

Rules: Not available with C07, D07 or C10.
1 Additional N.O. Auxiliary Drive Run Contact
K10

Provides 1 additional N.O. contact for drive run indication wired to TB1.

185.00

1 Additional N.C. Auxiliary Drive Fault Contact
L10

Provides 1 additional N.C. contact for drive fault indication wired to TB1.

185.00

1 N.O. Auxiliary Bypass Run Contact
M10

Provides 1 additional N.O. contact for bypass run indication wired to TB1.

185.00

Rules: Available only with Power Circuits Y, S, Z, R and T.
1 N.O. Auxiliary Auto Mode Contact
O10

Provides 1 additional N.O. contact for auto mode indication wired to TB1.

185.00

Rules: Not available with C07 or D07.
AFC Fault Reset Push-button
P10

Provides factory installed door-mounted push button to fault reset LI4 on the power converter at terminal TB1 when Hand-Off-Auto is not supplied.

100.00

Rules: 1. Available only with C07 or D07.
2. Available only with Power Circuit W.
Push-to-Test Pilot Lights
Q10

Provides push-to-test function on all pilot lights except Power On pilot light.

210.00

Rules: Not available on Fault pilot light if P10 is selected.
Auto Transfer to Bypass
R10

Provides an automatic transfer (time adjustable 0.1–10 s) to bypass in the event that the drive controller faults. A selector switch is provided inside
the enclosure to enable or disable this function. Longer transfer time requirements are available by replacing the plug-in adjustable timer.

270.00

Rules: 1. Available only with Power Circuits Y, S, Z, T or R.
2. Not available with B07, C07 or D07.
Motor Elapsed Time Meter
S10

Provides a dedicated elapsed time meter to record the motor run time. Runs whenever the motor is running. The motor elapsed time meter is
non-resettable.

270.00

Emergency Stop Mushroom Head Push-button
T10

Provides door mounted maintained off emergency stop red mushroom pushbutton with turn-to-reset feature.

127.00

Rules: Not available with C07 or D07.
Motor Space Heater Sequencing Circuit—Light Duty
U10

Provides 50 VA/120 V to terminal block TB1 for motor space heater whenever the motor is not running.

400.00

Rules: Mutually exclusive with V10 unless F10 is also selected.

30

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

Enclosed AC Drives
PowerGard™ Series C Enclosed Drive Controllers — Class 8839

MOD

Description

$ Price

Seal Water Solenoid
V10

Provides 50 VA/120 V to terminal block TB1 for seal water solenoid whenever the motor is running.

400.00

Rules: Exclusive with U10 unless F10 is also selected.
Check Valve Sequencing Circuit (Gravity Type)
Provides an automatic shutdown of the drive controller when the user supplied N.C. contact from the check valve limit switch does not open within
W10 5 seconds after the motor starts. The user limit switch contact connects to terminal block TB1. Circuit provides reset function with an illuminated
(blue) push-button.

520.00

54 inch wide enclosure
Y10

Provides a 54 inch wide switchboard enclosure for bottom conduit entry space provisions.

275.00

Rules: Available for 450–500 hp ratings only.
24 Vdc Power Supply
Z10

Provides a 24 Vdc, 300 mA power supply at terminal block TB1.

370.00

ID Engraved Nameplates
610

Provides an engraved laminated nameplate attached to the front door of the enclosure (engraved per user request at time of order).

100.00

Engineered Features
Factory orders with engineered features (E-MOD, SPL, etc.) are subject to review by factory personnel and have
longer lead-time availability. Standard PowerGard™ enclosure dimensions may no longer apply to orders containing
any combination of engineered features. In addition, factory orders containing engineered features may carry a
UL 508A (Industrial Control Equipment) label in lieu of a UL 508C (Power Conversion Equipment) label depending on
configuration.

Control Options
The E200 series features cover control circuit option configurations for PowerGard enclosed drive controllers.
E-MOD

Description

$ Price

Door mounted meters (dedicated displays)
Provides a dedicated door mounted meter display, analog or digital.
E201 Analog percent speed meter scaled 0 to 120% base speed.

540.00

E202 Analog percent current scaled 0 to 100% of rated output current.

540.00

E203 Digital ammeter (amperes) scaled 0 to 2 times rated output amperes.

630.00

E204 Digital speed meter (frequency) scaled 0 to 72 Hz output frequency.

630.00

E205 Digital percent speed meter scaled 0 to 120% base speed.

630.00

E206 Digital percent current scaled 0 to 100% of rated output current.

630.00

Rules: 1. Limited to one meter selection unless H09 is selected.
2. If H09 is selected, (1) additional meter can be selected.
Door mounted RJ45 port
(1) Sixnet RJ45 door mounted 30 mm bulk head connector and internal CAT5 cabling for access via PC with PowerSuite™ software.
E211 Provides
The RJ45 (Modbus™/CANopen) drive port provides customer access through the enclosure door.

325.00

Auxiliary drive run contacts
E212 Provides (3) Form 'C' contacts rated 5 A @ 120 V wired to terminal blocks for customer use.

310.00

Note: One (1) Form 'C' contact for drive run indication is supplied as standard.
Rules: 1. Available only if K10 is selected.
2. Available without K10 for 100–450 hp CT /125–500 hp VT.
Auxiliary bypass run contacts
E213 Provides (3) Form 'C' contacts rated 5 A @ 120 V wired to terminal blocks for customer use.

310.00

Note: One (1) N.O. contact for bypass run indication is supplied as standard when bypass is provided.
Rules: 1. Available only if M10 is selected.
2. Available without M10 for 100–450 hp CT / 125–500 hp VT.
Auxiliary drive fault contacts
E214 Provides (3) Form 'C' contacts rated 5 A @ 120 V wired to terminal blocks for customer use.

310.00

Note: One (1) Form 'C' contact for drive fault indication is supplied as standard.
Rules: Available only if L10 is selected.
Auxiliary auto mode contacts
E215 Provides (3) Form 'C' contacts rated 5 A @ 120 V wired to terminal blocks for customer use.

310.00

Note: One (1) N.O. contact for auto mode indication is supplied as standard when auto mod operation is provided.
Rules: Available only if O10 is selected.
Adjustable restart delay timer
an adjustable On Time Delay Relay for power up restart function, mounted and wired for AFC mode (hand or auto) mode and/or in the
E216 Provides
bypass mode (hand/auto).

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

240.00

31

Pricing Guide

Enclosed AC Drives
PowerGard™ Series C Enclosed Drive Controllers — Class 8839
E-MOD

Description

$ Price

Motor space heater (heavy duty)
E217 Provides control circuit contacts, 120 V, 500 VA supply and fusing wired to terminals for customer use.

1000.00

Signal loss follower alarm relay
Provides (1) Form 'C' contact rated 5 A @ 120 V wired to terminal blocks for customer use. Intended for 4–20 mAdc control loop applications
E218 where upon the loss of input signal it is desired to retain the output signal at the last input signal level. The relay provides an alarm relay contact
for signal loss alert.

360.00

Note: Requires use of logic output LO1.
Inhibit/shutdown sequence (timed operation)
a relay circuit operating in the fail safe mode where a remote initiating contact opens the relay, de-energizes and after a specified time
E219 Provides
shuts the drive controller down in the AFC mode (hand or auto) and/or in the bypass mode (hand or auto).

580.00

Check valve sequence (motorized type)
Provides relay circuitry sequenced from a check valve limit switch. A valve closed position limit switch will energize relays that will initiate a remote
operating solenoid limited to 50 VA and give a run permissive to the drive controller in the AFC mode (hand or auto) and/or in the bypass
E220 valve
mode (hand or auto). A valve closed position limit switch will de-energize a timer relay such that if this relay is not de-energized within a specified
time period, the drive controller will shut down in the AFC mode (hand or auto) and/or in the bypass mode (hand or auto).

710.00

Seal water solenoid—with pressure switch feedback
Provides relay, which will energize a remote seal water solenoid limited to 50 VA during drive controller operation. Additionally, the remote initiating
E221 contact will open the relay, de-energizing and after a specified time shuts the drive controller down in the AFC mode (hand or auto) and/or in the
bypass mode (hand or auto).

1220.00

Moisture detection relay circuit (without relay)
24 V or 120 V control power to a customer supplied moisture detection relay device, either electronic or electro-mechanical. Factory
E222 Provides
provides pre-wired socket or mounting space only.

350.00

Note: Customer supplies relay. Details concerning type must also be provided at time of order entry in “Engineering Notes” within Q2C.
Moisture detection relay circuit (with relay options)
option: Provides 24 V or 120 V control power to a moisture detection relay device, either electronic or electro-mechanical. The moisture
E223A Relay
detection relay is mounted and wired by the factory.

1220.00

Relay and Pilot Light indication option: Provides 24 V or 120 V control power to a customer supplied moisture detection relay device, either
E223B electronic or electro-mechanical. Includes a pilot light for discrete input(s). The customer supplied moisture detection relay is mounted and wired
by the factory.

1395.00

Note: Details concerning type must be provided at time of order entry in “Engineering Notes” within Q2C.
Substitute Type K operators
E224 Provides Class 9001 Type K 30 mm heavy duty multi-function operators in lieu of standard 22 mm pilot devices.

410.00

Spare control relays (for customer use)
150.00
each

E225 Provides control relays mounted and unwired for customer use. Up to (3) are available.
Substitute pilot light lens color(s)
E226 Provides the flexibility to configure lens cap colors to contract equipment designations.

—

Notes: Specify lens cap colors desired at time of order entry in “Engineering Notes” field within Q2C.
Blown fuse indicators on control fuses
E227 Provides blown circuit fuse indicators on control circuit fuses in lieu of standard fuses.

750.00

Motor over temperature logic input
E228 Provides dedicated terminals using an external motor over temperature input (N.C. contact) factory wired and programmed.

186.00

RTD inputs (motor protection alarm)
E229 Provides capability for accepting RTD inputs using an RTD limit alarm, factory mounted and wired. Limited to three (3) RTD inputs.

4122.00

Note: Specify RTD values at time of order entry in 'Engineering Notes' within Q2C.
Motor management relay option
Provides motor protection and metering functions using a selection of motor management relays. This relay provides protection for motor and load conditions:
overload, differential, stator temperature, high inertia loads, undercurrent, under power, jam and bearing over temperature. The motor management relay is factory
mounted and wired. Includes PT's and CT's.
E230A Schneider Electric Sepam™ Series 20 motor protective relay
E230B Schneider Electric Sepam Series 41 motor protective relay

2850.00
3975.00

E230C GE Multilin® 269+ motor management relay

13995.00

E230D GE Multilin 469 motor management relay

14750.00

PowerLogic™ power meter display option
Provides a Class 3020 PM800 series power module true rms meter display with basic instrumentation, demand, THD, date/time stamping, neutral current, min/max,
alarms, event and data storage factory mounted and wired.

32

E231A PM820 power module

1400.00

E231B PM850 power module

1550.00

E231C PM870 power module

1995.00

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

Enclosed AC Drives
PowerGard™ Series C Enclosed Drive Controllers — Class 8839

E-MOD

Description

$ Price

PowerLogic™ circuit monitor option
Provides a Class 3020 CM3000/CM4000 series circuit monitor display with instrumentation, 0.2% accuracy, data logging and waveform capture, factory mounted
and wired. Includes PT's and CT's.
E232A CM3250 circuit monitor

2415.00

E232B CM3350 circuit monito

2415.00

E232C CM4000T circuit monitor

4275.00

E232D CM4250 circuit monitor

4275.00

Spare terminal blocks (unwired)
E234 Provides (10) spare terminal blocks 'unwired' for customer use using the Class 9080 Type G series terminals.

120.00

End damper control circuit
a damper control circuit to coordinate starting of the drive controller or the bypass with the position of the damper. Requires
E235 Provides
connection to customer damper limit switch.

240.00

Emergency power off push-button
Provides a shunt trip modified molded case switch or circuit breaker where a push-pull maintained mushroom head push-button energizes the
E236 shunt trip coil and instantaneously opens to shut down power supplied to the drive controller in the AFC mode and/or bypass mode, coasting to
an uncontrolled stop.

540.00

Audible alarm horn with silence
an audible alarm horn, timer to annunciate a user defined conditions with a silencer push-button, factory assembled and wired for
E238 Provides
customer use.

625.00

Three-phase ammeter with selector switch
Provides 3 CT's with 3-position selector switch to indicate Phase A, B or C connected on the motor leads to monitor full load amps.
E239A Monitor input full load amps

1575.00

E239B Monitor output full load amps

1575.00

Basin high level alarm indication option
with pilot light: Provides relay circuit and pilot light indicator alarm for high level alarm limit switch via contact closure. Includes master reset
E240A Alarm
push-button and (1) Form 'C' contact for customer use.

795.00

Command to run and alarm with pilot light indication: Provides relay circuit, timer and pilot light indicator sequenced for high level alarm limit switch
E240B via contact closure, energizing the drive controller and/or bypass to run full speed. Includes master reset push-button and (1) Form 'C' contact for
customer use.

895.00

Basin low level stop with pilot light indication
relay circuit and pilot light indicator sequenced for low level alarm limit switch via N.O./N.C. contact closure, causing the drive controller
E241 Provides
to stop. Includes master reset push-button and (1) Form 'C' contact for customer use.

795.00

Enclosure ventilation fan shutdown
E242 Provides interlocking and timer functions of enclosure ventilation fans to shutdown during drive controller idle conditions.

795.00

High discharge pressure with pilot light indication
relay circuitry with pilot light indicator sequenced from a pressure switch input, causing the drive controller to stop. Includes master reset
E243 Provides
push-button and (1) Form 'C' contact for customer use.

795.00

Low discharge pressure with pilot light indication
relay circuit, timer with pilot light sequenced from a pressure switch input when low discharge condition. Includes master reset
E244 Provides
push-button and (1) Form 'C' contact for customer use.

795.00

Low seal water shutdown with pilot light indication
relay circuitry, timer with pilot light sequenced from a pressure switch input when not enough seal water is supplied. Includes master reset
E245 Provides
push-button and (1) Form 'C' contact for customer use.

795.00

Rules: Mutually exclusive to E221.
Motor over temperature shutdown with pilot light
dedicated terminals using an external motor over temperature input (Form 'C' contact) and a pilot light indicator factory wired and
E246 Provides
programmed.

380.00

Rules: Mutually exclusive to E228.
Phase failure relay
a phase failure relay (Tele RM4T series) mounted and wired to indicate phase reversal, phase loss and imbalance operating
E247 Provides
conditions.

725.00

Rules: Available with Power Circuits Y, Z, S, T, or R only.
Single test pilot light push-button
E248 Provides a dedicated 30 mm push-to-test button for indication of operable pilot lights.

130.00

Rules: Must also select E224.
Substitute TeSys™ 600 V relay(s)
E249 Substitutes TeSys Type NEMA® rated relays rated 600 V, 10 A.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

985.00

33

Pricing Guide

Enclosed AC Drives
PowerGard™ Series C Enclosed Drive Controllers — Class 8839

Enclosure & Miscellaneous Modifications
The E300 series features cover enclosure and miscellaneous option configurations for the PowerGard™ enclosed
drive controller.
E-MOD

Description

$ Price

ANSI #61 enclosure paint
E301 Provides option to configure enclosure paint to industry standard ANSI #61 light gray paint in lieu of ANSI #49 gray.

526.00

Enclosure space heater option
E305A Space heater only: Provides a Hoffman type enclosure strip heater and thermostat to maintain internal low temperature ambient ratings.

1500.00

heater with storage operation provision: Provides a Hoffman type enclosure strip heater and thermostat to maintain internal low
E305B Space
temperature ambient ratings. Includes 120 V remote source input terminals for operation during storage conditions.

1800.00

Power Options
The E400 series features cover engineered power option configurations for PowerGard enclosed drive controllers.
E-MOD

Description

$ Price

Motor protection filter
Provides a factory mounted and wired dV/dt filter on the drive output for long motor lead lengths considerations in excess of our published guidelines, up to 1000 feet.
40 hp CT 1895.00
50–60 hp 2675.00
75 hp 3145.00
100 hp 3675.00
125 hp 5025.00
150 hp 5230.00

E402

200 hp 5330.00
250 hp 5365.00
300 hp 5645.00
350 hp 6540.00
400hp 6980.00
450–500 hp 7310.00

Transient voltage surge suppressor
supplementary surge protection using a Class 1310 TVSS XWF Series Transient Voltage Surge Suppressor hard-wired and factory
E405 Provides
mounted. 100,000 peak volts of surge protection.

1885.00

Note: Service connection type (Delta or Wye) must be specified in “Engineering Notes” within Q2C.
Secondary surge arrestor
E413 Provides a secondary surge arrester Class 6671 SDSA3650 mounted and wired.

485.00

3% output reactor
Provides a 3% rated output reactor to address long lead considerations, mounted and wired.
40 hp CT 1450.00
50–60 hp 1650.00
75–100 hp 1750.00
125 hp 1850.00
E414

150 hp 2050.00
200 hp 3150.00
250 hp 3450.00
300–350 hp 4350.00
400–450 hp CT / 400–500 hp VT 4850.00

34

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drive Products
Altivar™ 12 Drives

Table 18:

Selection and Pricing
Voltage + 10% -15% 50/60 Hz

a
b
c
d

Input

Output

Horsepower

Motor Powera
kW

Nominal
Current Rating
A

Catalog
Numberb

115 V
single-phase

230 V
three-phase

230 V
single-phase

230 V
three-phase

230 V
three-phase

230 V
three-phase

0.25
0.5
1
0.25
0.5
0.75
1
2
3
0.25
0.5
1
2
3
—
5

0.18
0.37
0.75
0.18
0.37
0.55
0.75
1.5
2.2
0.18
0.37
0.75
1.5
2.2
3
3.7

1.4
2.4
4.2
1.4
2.4
3.5
4.2
7.5
10
1.4
2.4
4.2
7.5
10
12.2
16.7

ATV12H018F1
ATV12•037F1
ATV12H075F1
ATV12H018M2c
ATV12•037M2c
ATV12•055M2c
ATV12•075M2c
ATV12HU15M2d
ATV12HU22M2d
ATV12H018M3
ATV12•037M3
ATV12•075M3
ATV12•U15M3
ATV12•U22M3
ATV12•U30M3
ATV12•U40M3

$ Price

These power ratings are for use as switching frequency of 4 kHz, in continuous operation.
The ATV12 part numbers with the • are available as H or P version (reference installation manual BBV28587 for heatsink version). Replace the • with H for drives
with standard heatsink on the back of the drive. Example: ATV12H037M2 has a heatsink. Replace the • with P for drives without a heatsink. These drives do not
have a heatsink but have a smooth back that can be mounted to a thermally conductive machined surface. Example: ATV12P037M2 does not have a heatsink.
Available in lots of 14 by adding TQ to the end of the reference number.
Available in lots of 7 by adding TQ to the end of the reference number.

Table 19:

Options and Accessories
Description

Part Number

For Use on Drives

$ Price

Software
SoMove™ Lite
This software enables the user to configure, set, debug and organize maintenance task for the Altivar 12 drive.
It can also be used to customize the integrated display terminal menus. It can be used with a direct connection or a Bluetooth® wireless connection.
Free download at http://products.schneider-electric.us/products-services/products/ac-drives-and-soft-starts/
USB to RJ45 adaptor: for use in
device families: Advantys™ OTB, Altistart™ motor starters, Altivar series including
TCSMCNAM3M002P Compatible
connecting to a PC with a USB port
HMI, Altivar controller
User Interface Options
Remote Keypad Display for ATV12 (IP54)
VW3A1006
ATV12 and ATV312
Remote Keypad Display for ATV12 (IP65)
VW3A1007
ATV12 and ATV312
Cable for remote mounting LCD graphic keypad RJ-45 connector on each end
1 meter
VW3A1104R10
3 meters
VW3A1104R30
any Altivar drive
5 meters
VW3A1104R50
10 meters
VW3A1104R100
Operator, mounting collar, 2.5 kilohm, 1⁄2
ATVPOT25K
any Altivar drive
watt potentiometer
Conformity Kits
ATV12H018F1, H037F1, ATV12H018M2…H075M2, ATV12H018M3…H075M3, ATV12P037F1,
EMC Conformity Kit
VW3A9523
ATV12P037M2…P075M2, ATV12P037M3...P075M3
EMC Conformity Kit
VW3A9524
ATV12H075F1, ATV12HU15M2, HU22M2, ATV12HU15M3,HU22M3, ATV12PU15M3, PU22M3
EMC Conformity Kit
VW3A9525
ATV12HU30M3, ATV12HU40M3
Filters
EMC Filters for C1, C2, C3
VW3A4416
ATV12H018F1, H037F1, ATV12H018M2…H075M2, ATV12P037F1, ATV12P037M2…P075M2
EMC Filters for C1, C2, C3
VW3A4417
ATV12H075F1, ATV12HU15M2, HU22M2
EMC Filters for C1, C2, C3
VW3A4418
ATV12H018M3…H075M3, ATV12P037M3…P075M3
EMC Filters for C1, C2, C3
VW3A4419
ATV12HU15M3, HU22M3, ATV12PU15M3,PU22M3
Converters
15 / 24 voltage converter
VW3A9317
All ATV12 ranges
Mounting Kits
Mounting Plate for 35 mm DIN rail
VW3A9804
ATV12H018F1, H037F1, ATV12H018M2…H075M2, ATV12H018M3…H075M3
Mounting Plate for 35 mm DIN rail
VW3A9805
ATV12H075F1, ATV12HU15M2, HU22M2, ATV12HU15M3,HU22M3

Table 20:

Description

56.00
56.00
35.00
35.00
35.00
45.00
69.00

25.00
25.00
25.00
130.00
125.00
219.00
233.00
88.00
64.00
72.00

Part Number
VZ3V1301
VZ3V1302
VY1A12A01

For Use on Drives

$ Price
a
a
a

ATV12H075F1, ATV12U15M2, HU22M2
ATV12HU15M3...HU40M3
All ATV12 ranges

Available 4th Qtr 2011.

Table 21:

Configuration Tools
Description

Universal Bluetooth Interface: Bluetooth connectivity to devices through serial RS-485, RJ45 Modbus
port. For permanent installation, to be used during commissioning, maintenance and troubleshooting
of equipment.
Simple Loader: to transfer configuration between like drives. For use with the Altivar product line.
Multi-loader: to copy a configuration from a drive or from SoMove via an SD card, and transferring to
another drive or to a PC
Guiding tool cable: for connection between the MultiLoader and an ATV12 that is in its packaging
b

52.00

Replacement Parts

Replacement Fan
Replacement Fan
Plastic part kit: door, upper and lower wire cover
a

181.00
188.00
220.00
181.00
188.00
201.00
220.00
285.00
342.00
166.00
173.00
202.00
262.00
314.00
364.00
427.00

Part Number
TCSWAAC13FBb
VW3A8120
VW3A8121
VW3A8126

For Use on Drives
Altivar 12, 212, 312, 61, 71,
and Altistart 22

$ Price
180.00

ATV12,ATV312,ATV32,ATV61,ATV71 175.00
ATV12, ATV312, ATV212, ATV32,
350.00
ATV61, ATV71, ATS22
ATV12, ATV32, Lexium 32
30.00

Discount Schedule for this product is PC41.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4B PC41b Discount
Schedule

35

Pricing Guide

AC Drive Products
Altivar™ 312 / 31C Drives

Selection and Pricing
Table 22:

Altivar™ 312 Selection and Pricing
Three-Phase Motor Powera

Open Drivesb
Continuous
Output Current

Input Line Voltage
HP

kW

Catalog Number

$ Price

A

a
b
c

208/230 Vac
Single-Phase

0.25
0.5
0.75
1
1.5
2
3

0.18
0.37
0.55
0.75
1.1
1.5
2.2

1.5
3.3
3.7
4.6
6.9
8
11

ATV312H018M2
ATV312H037M2
ATV312H055M2
ATV312H075M2
ATV312HU11M2
ATV312HU15M2
ATV312HU22M2

268.00
287.00
306.00
335.00
363.00
402.00
468.00

208/230 Vac
Three-Phase

0.25
0.5
0.75
1
1.5
2
3
4
5
7.5
10
15
20

0.18
0.37
0.55
0.75
1.1
1.5
2.2
3
—
5.5
7.5
11
15

1.5
3.3
3.7
4.8
6.9
8
11
13.7
17.5
27.5
33
54
66

ATV312H018M3
ATV312H037M3
ATV312H055M3
ATV312H075M3
ATV312HU11M3
ATV312HU15M3
ATV312HU22M3
ATV312HU30M3
ATV312HU40M3
ATV312HU55M3
ATV312HU75M3
ATV312HD11M3
ATV312HD15M3

258.00
287.00
306.00
325.00
363.00
421.00
478.00
554.00
650.00
841.00
1013.00
1338.00
1721.00

400/480 Vac
Three-Phase

0.5
0.75
1
1.5
2
3
4
5
7.5
10
15
20

0.37
0.55
0.75
1.1
1.5
2.2
3
—
5.5
7.5
11
15

1.5
1.9
2.3
3
4.1
5.5
7.1
9.5
14.3
17
27.7
33

ATV312H037N4
ATV312H055N4
ATV312H075N4
ATV312HU11N4
ATV312HU15N4
ATV312HU22N4
ATV312HU30N4
ATV312HU40N4
ATV312HU55N4
ATV312HU75N4
ATV312HD11N4
ATV312HD15N4

363.00
392.00
421.00
449.00
497.00
574.00
650.00
688.00
860.00
1052.00
1386.00
1721.00

575/600 Vac
Three-Phasec

1
2
3
5
7.5
10
15
20

0.75
1.5
2.2
3.7/4.0
5.5
7.5
11
15

1.7
2.7
3.9
6.1
9
11
17
22

ATV312H075S6
ATV312HU15S6
ATV312HU22S6
ATV312HU40S6
ATV312HU55S6
ATV312HU75S6
ATV312HD11S6
ATV312HD15S6

484.00
572.00
660.00
792.00
989.00
1209.00
1594.00
1979.00

These horsepower, wattage, and continuous ampere ratings apply to 4 kHz switching frequency and maximum 50 °C ambient. Refer to the installation
manual for derating curves as a function of switching frequency, ambient temperature, and mounting conditions.
Open type Altivar 312 Drives can be installed as UL Type 1 with optional conduit box when following instructions in the installation manual.
A minimum 3% line reactor is required on all 575 V drive installations.

Selection and Pricing
Table 23:

Altivar 31 UL Type 12 / IP54 Selection and Pricing
Three-Phase Motor Powera

Input Line
Voltage

IP54 / UL Type 12 Enclosed
Standard
$ Price

kW

HP

Aa

Catalog Number

208/230 Vac
Single-Phase

0.18
0.37
0.55
0.75
1.1
1.5
2.2

0.25
0.5
0.75
1
1.5
2
3

1.5
3.3
3.7
4.6
6.9
8
11

ATV31C018M2
ATV31C037M2
ATV31C055M2
ATV31C075M2
ATV31CU11M2
ATV31CU15M2
ATV31CU22M2

362.00
387.00
413.00
452.00
490.00
543.00
632.00

400/480 Vac
Three-Phase

0.37
0.55
0.75
1.1
1.5
2.2
3
—
5.5
7.5
11
15

0.5
0.75
1
1.5
2
3
4
5
7.5
10
15
20

1.5
1.9
2.3
3
4.1
5.5
7.1
9.5
14.3
17
27.7
33

ATV31C037N4
ATV31C055N4
ATV31C075N4
ATV31CU11N4
ATV31CU15N4
ATV31CU22N4
ATV31CU30N4
ATV31CU40N4
ATV31CU55N4
ATV31CU75N4
ATV31CD11N4
ATV31CD15N4

490.00
529.00
568.00
606.00
671.00
774.00
878.00
929.00
1162.00
1420.00
1733.00
2151.00

ATV31C
IP54 / UL Type 12
a

36

Open
Drivesb

These horsepower, wattage, and continuous ampere ratings apply to 4 kHz switching frequency and maximum 50 °C ambient. Refer to the installation
manual for derating curves as a function of switching frequency, ambient temperature, and mounting conditions.

CP4B

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drive Products
Altivar™ 312 Drives

Table 24:

Altivar™ 312 Options and Accessories
Description

For Use on Drives

Catalog Number

$ Price

Software
SoMove™ Lite
This software enables the user to configure, set, debug and organize maintenance task for the Altivar 312 drive.
It can also be used to customize the integrated display terminal menus. It can be used with a direct connection or a Bluetooth® wireless connection.
Free download at http://products.schneider-electric.us/products-services/products/ac-drives-and-soft-starts/
Powersuite™ Test and
Software on CD-ROM. For use with Microsoft Windows™ 95, 98, NT,
ATV312 all ranges
VW3A8104
Commissioning Software Kit and XP operating systems for PCs

150.00

User Interface Kits
USB to RJ45 Adaptor Kit

For use in connecting to a PC with a USB port

Remote
Keypad Options and
Accessories

Remote Keypad Display (IP54)
Remote Keypad Display (IP65)
Remote Keypad Display and Mounting Kit
Remote Keypad Display
1 meter
3 meters
5 meters
10 meters
Profibus
CANopen Daisy Chain
DeviceNet
Operator, mounting collar, 2.5 kilohm, 1⁄2 watt potentiometer

Cable for remote mounting
LCD graphic keypad. RJ-45
connector on each end.
Communication
Options
Potentiometer

Advantys™ OTB, Altistart™
motor starters, Altivar series TCSMCNAM3M002P 52.00
incl. HMI, Altivar controller
ATV312, ATV12
VW3A1006
56.00
ATV312, ATV12
VW3A1007
56.00
ATV312
VW3A31101
175.00
ATV312, ATV61, ATV71
VW3A1101
115.00
Any ATV61, Any ATV71
VW3A1104R10
35.00
Any ATV61, Any ATV71
VW3A1104R30
35.00
Any ATV61, Any ATV71
VW3A1104R50
35.00
Any ATV61, Any ATV71
VW3A1104R100
45.00
ATV312
VW3A31207
185.00
ATV312
VW3A31208
185.00
ATV312
VW3A31209
185.00
Altivar 312

ATVPOT25K

69.00

NOTE: Reference Catalog #8800CT0401 for communication cables.
Table 25:

Configuration Tools
Description

Part Number

For Use on Drives

$ Price

Universal Bluetooth Interface: Bluetooth connectivity to devices through serial RS-485, RJ45
12, 212, 312, 61, 71, and
Modbus port. For permanent installation, to be used during commissioning, maintenance and TCSWAAC13FBb Altivar
180.00
Altistart 22
troubleshooting of equipment.
Simple Loader: to transfer configuration between like drives. For use with the Altivar product
ATV12, ATV312, ATV32, ATV61 175.00
VW3A8120
line.
and ATV71
Multi-loader: to copy a configuration from a drive or from SoMove via an SD card, and
ATV12, ATV312, ATV212, ATV32, 350.00
VW3A8121
transferring to another drive or to a PC
ATV61, ATV71 and ATS22
b

Discount Schedule for this product is PC41.

Table 26:

Options—Field Installed Kits
Description

DIN Rail
Mount Kit

Conduit
Entrance Kit

ATV28
Replacement
Kit

Dynamic
Braking
Resistor Kit

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

For Use on Drives

ATV312H018M2, ATV312H037M2,
ATV312H055M2, ATV312H075M2,
ATV312H018M3, ATV312H037M3,
ATV312H055M3, ATV312H075M3
ATV312HU11M2, ATV312HU15M2,
DIN Rail Mounting Plate for 35 mm wide DIN rail
ATV312HU11M3, ATV312HU15M3,
ATV312HU22M3, ATV312H037N4,
ATV312H055N4, ATV312H075N4,
ATV312HU11N4, ATV312HU15N4,
ATV312H075S6, ATV312HU15S6
ATV312H018M2, ATV312H037M2,
ATV312H055M2, ATV312H075M2
ATV312H018M3, ATV312H037M3,
ATV312H055M3, ATV312H075M3
ATV312HU11M3, ATV312HU15M3
ATV312HU11M2, ATV312HU15M2,
ATV312HU22M3, ATV312H037N4,
ATV312H055N4, ATV312H075N4,
ATV312HU11N4, ATV312HU15N4,
Multiple knockout sizes
Installation of conduit entrance kit and retention of vent cover on ATV312H075S6, ATV312HU15S6
top of drive controller provides the ATV31 with UL Type 1 rating. ATV312HU22M2, ATV312HU30M3,
ATV312HU40M3, ATV312HU22N4,
ATV312HU30N4, ATV312HU40N4,
ATV312HU22S6, ATV312HU40S6
ATV312HU55M3, ATV312HU75M3,
ATV312HU55N4, ATV312HU75N4,
ATV312HU55S6, ATV312HU75S6
ATV312HD11M3, ATV312HD15M3,
ATV312HD11N4, ATV312HD15N4,
ATV312HD11S6, ATV312HD15S6
ATV312H018M2, ATV312H037M2,
ATV312H055M2, ATV312H075M2
ATV312H018M3, ATV312H037M3,
This kit contains brackets that adapt the spacing of the ATV312 ATV312H055M3, ATV312H075M3
mounting holes to be equivalent to that of an ATV28 with the
ATV312HU11M2, ATV312HU15M2,
same rating. This will permit the ATV312 to be secured to the
ATV312HU11M3, ATV312HU15M3,
panel holes and mounting hardware already in place for the
ATV312HU22M3, ATV312H075S6,
ATV28.
ATV312HU15S6
ATV312HU55M3, ATV312HU75M3,
ATV312HU55N4, ATV312HU75N4,
ATV312HU55S6, ATV312HU75S6
ATV312H018M2–037M2
ATV312H018M3–037M3
ATV312H037N4–U40N4
ATV312H055M2–U22M2
ATV312H055M3–U22M3
DB resistors are provided in a Type 1 enclosure and are
ATV312HU55N4–U75N4
thermally protected.
ATV312HU30M3–U40M3
ATV312HD11N4–D15N4
ATV312HU55M3–U75M3
ATV312HD11M3–D15M3

CP4B PC41b Discount
Schedule

Catalog Number

$ Price

VW3A9804

72.00

VW3A9805

72.00

VW3A31812

45.00

VW3A31811

45.00

VW3A31813

45.00

VW3A31814

45.00

VW3A31815

45.00

VW3A31816

45.00

VW3A31817

45.00

VW3A31821

25.00

VW3A31822

25.00

VW3A31823

25.00

VW3A66711

422.00

VW3A66712

633.00

VW3A66713

950.00

VW3A66714
VW3A66715

1266.00
1846.00

37

Pricing Guide

AC Drive Products
Altivar™ 312 Drives
Options—Field Installed Kits (Continued)
Description

For Use on Drives

230/460 V

ATV312H075S6

Open Style

Line Reactors

575 V

Enclosed (Type 1)

Single-phase
supply voltage:
200–240 V 50/60 Hz

RFI Input Filter

For compliance with European
(CE) conducted emissions
standard 55022 Class B
(Class A filter built into
230/460 V ATV31 drives)

3 phase supply
voltage: 200–240 V
50/60 Hz

3 phase supply
voltage: 380–500 V
50/60 Hz

38

Catalog Number

$ Price

See page 56 of this Price Guide.

CP4B

Discount
Schedule

RL00202

158.00

ATV312HU15S6
ATV312HU22S6

RL00403

163.00

ATV312HU40S6
ATV312HU55S6
ATV312HU75S6
ATV312HD11S6
ATV312HD15S6

RL00803
RL00802
RL01202
RL01802
RL02502

245.00
179.00
200.00
253.00
291.00

ATV312H075S6

RL00212

289.00

ATV312HU15S6
ATV312HU22S6

RL00413

294.00

ATV312HU40S6
ATV312HU55S6
ATV312HU75S6
ATV312HD11S6
ATV312HD15S6

RL00813
RL00812
RL01212
RL01812
RL02512

379.00
310.00
332.00
388.00
507.00

ATV312H037M2 ATV312H055M2
ATV312H075M2

VW3A31401

58.00

ATV312HU11M2 ATV312HU15M2

VW3A31403

79.00

ATV312HU22M2

VW3A31405

108.00

ATV312H018M3 ATV312H037M3
ATV312H055M3 ATV312H075M3

VW3A31402

72.00

ATV312HU11M3 ATV312HU15M3
ATV312HU22M3

VW3A31404

90.00

ATV312HU30M3 ATV312HU40M3

VW3A31406

133.00

ATV312HU55M3 ATV312HU75M3

VW3A31407

189.00

ATV312HD11M3 ATV312HD15M3

VW3A31408

297.00

ATV312HD11N4 ATV312HD15N4

VW3A31409

243.00

ATV312H037N4 ATV312H055N4
ATV312H075N4 ATV312HU11N4
ATV312HU15N4

VW3A31404

90.00

ATV312HU22N4 ATV312HU30N4
ATV312HU40N4

VW3A31406

133.00

ATV312HU55N4 ATV312HU75N4

VW3A31407

189.00

ATV312HD11N4 ATV312HD15N4

VW3A31409

243.00

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drive Products
Altivar™ 32 Drives

Selection and Pricing
The Altivar™ 32 is intended for use with three-phase asynchronous and synchronous motors.
Select the Altivar 32 using the nameplate voltage and full load ampere rating of the motor and the table below. The
horsepower ratings are for reference only.
Table 27:
Size A

Size B
Input Line
Voltage

Altivar 32 Selection and Pricing
Three-Phase Continuous
Output
Motor Power
Current
HP

kW

A

200–240 Vac
Single-Phase
Input

0.25
0.50
0.75
1
1.5
2
3

0.18
0.37
0.55
0.75
1.10
1.50
2.20

1.5
3.3
3.7
4.8
6.9
8
11

380–480 Vac
Three-Phase
Input

0.50
0.75
1
1.5
2
3
4
5
7.5
10
15
20

0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15

1.5
1.9
2.3
3
4.1
5.5
7.1
9.5
14.3
17
27.7
33

Size C

Size D

Dimensions
Catalog Number

W

H

Frame
Size

D

$ Price

IN

mm

IN

mm

IN

mm

ATV32H018M2
ATV32H037M2
ATV32H055M2
ATV32H075M2
ATV32HU11M2
ATV32HU15M2
ATV32HU22M2

1.77
1.77
1.77
1.77
2.36
2.36
2.36

45
45
45
45
60
60
60

12.8
12.8
12.8
12.8
12.8
12.8
12.8

325
325
325
325
325
325
325

9.65
9.65
9.65
9.65
9.65
9.65
9.65

245
245
245
245
245
245
245

A
A
A
A
B
B
B

335.00
365.00
395.00
420.00
475.00
525.00
620.00

ATV32H037N4
ATV32H055N4
ATV32H075N4
ATV32HU11N4
ATV32HU15N4
ATV32HU22N4
ATV32HU30N4
ATV32HU40N4
ATV32HU55N4
ATV32HU75N4
ATV32HD11N4
ATV32HD15N4

1.77
1.77
1.77
1.77
1.77
2.36
2.36
2.36
5.90
5.90
7.08
7.08

45
45
45
45
45
60
60
60
150
150
180
180

12.8
12.8
12.8
12.8
12.8
12.8
12.8
12.8
9.25
9.25
13
13

325
325
325
325
325
325
325
325
235
235
330
330

9.65
9.65
9.65
9.65
9.65
9.65
9.65
9.65
9.13
9.13
9.13
9.13

245
245
245
245
245
245
245
245
232
232
232
232

A
A
A
A
A
B
B
B
C
C
D
D

490.00
525.00
550.00
602.00
665.00
751.00
852.00
980.00
1191.00
1455.00
1825.00
2325.00

Network Communication Option Cards
The Altivar 32 can accept one of the following network communication option cards. The card slides into the Altivar 32
without taking up addition panel space, CANopen from the embedded port is disabled when an option card is
installed.
VW3 A3 608

Table 28:

Network Communication Option Card Selection and Pricing
Description

Catalog Number

CANopen daisy chain option card, two RJ45 ports

VW3 A3 628

130.00

VW3CANCARR03

25.00

1 meter CANopen cable with two RJ45 connectors

VW3CANCARR1

25.00

CANopen end of line terminator with RJ45 connector

TCSCAR013M120b

IP20 CANopen junction box with:
2 screw terminal blocks for trunk cable tap connection
2 RJ45 connectors for connection to drives
1 RJ45 connector for connecting a PC

VW3CANTAP2

130.00

VW3A3618b

149.00

VW3A3628

130.00

VW3A3607b

281.00

VW3A3609

185.00

CANopen single port option card, 9 pin male SUB-D connector
Profibus DP V1 single port option card, 9 pin male SUB-D connector
Supports CiA 402 drive profile and Profidrive profile, Offers several message handling modes based on DP V1
DeviceNet™ single port option card, removable 5 position screw connector
Supports CIP AC drive profile and CiA 402 drive profile.

2

20.00

Ethernet IP—Modbus™ TCP/IP daisy chain option card, two RJ45 ports
10/100 Mbps, half duplex and full duplex, embedded web server,

VW3A3616b

250.00

EtherCAT daisy chain option card, two RJ45 ports

VW3A3601b

300.00

b

Discount Schedule for this product is PC51.

Table 29:

Mounting Accessories
Description

Mounting using VW3A9920

$ Price

0.3 meter CANopen cable with two RJ45 connectors

CANopen single port option card, removable 5 position screw connector

VW3 A3 616

Qty.

VW3A3608b

Catalog Number

Qty.

Adaptor to mount the ATV32 control module rotated 90°
to
Use this adaptor to mount the ATV32 control module rotated 90°, allowing the ATV32H…M2
ATV32H037N4…U40N4
ATV32 to be mounted in a shallow enclosure.

VW3A9920

1

45.00

Bracket for mounting GV2 manual protector on an ATV 32
Metal bracket mounts to the ATV32 and holds a GV2. Requires a GV2AF4
adaptor for electrical connections. Must order in sets of 10.

ATV32H…M2 to
ATV32H037N4…U40N4

VW3A9921

1

4.50

Adaptor for use with mounting a GV2 on an ATV 32
Provides electrical power connections between GV2 and ATV32. Requires a
VW39921 bracket to mount the GV2. Must order in sets of 10.

ATV32H…M2 to
ATV32H037N4…U40N4

GV2AF4a

1

3.20

a

For Use On

$ Price

Discount Schedule for this product is I11.

DC Bus Connectors
GV mounted using
VW3A9921 and GV 2AF4

Use these connectors to daisy chain multiple Altivar 32 drives together to balance acceleration and decelerating
loads. (Use in addition to dynamic braking resistors in this type of application.) Or use these connectors when the
drives are powered at the DC bus only.
Table 30:

Mounting Accessories
Description

Use To Connect

Catalog Number

Daisy chain DC bus cord with two connectors

ATV32H…M2
ATV32H037N4…U40N4

VW3M7101R01b

Daisy chain DC bus cord with one connector and flying leads at one end

ATV32H037N4…U40N4
to ATV32HU55N4…D15N4

VW3M7102R150b

Daisy chain DC bus cord with two connectors

ATV32H037N4…U40N4
to ATV32HU55N4…D15N4

VW3M2207b

b

Qty. $ Price
5

83.00
115.00

10

115.00

Discount Schedule for this product is PC51.

Mounting using
VW3M7101R01
© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

I11a

PC51b

CP4B

Discount
Schedule

39

Pricing Guide

AC Drive Products
Altivar™ 32 Drives

Options and Accessories
IP 65 Rated Dynamic Braking Resistors for the Altivar™ 32
For use with high inertia motor loads, generating motor mode loads and machines with fast cycle times.
See Altivar 32 Installation Manual for sizing information
Table 31:

Altivar 32 Options and Accessories

For Use On

VW3 A7 608 R••

Resistor Description
Ohmic Value: Average Power
Available at 50 °C

Minimum Resistor Value to
Connect to the Drive: ohms

ohms

watts

100

100

Catalog Number

Cable
Length:
m

VW3A7608R07a

0.75

305.00

$ Price

ATV32H018M2…H075M2
ATV32H037N4…H075N4

40
80

ATV32HU11N4…HU22N4

54

VW3A7608R30a

3

413.00

ATV32HU11M2…HU15M2

27

72

100

VW3A7605R07a
VW3A7605R30a

0.75
3

180.00
243.00

ATV32HU22M2

25

27

200

VW3A7603R07a
VW3A7603R30a

0.75
3

203.00
261.00

ATV32HU30N4
ATV32HU40N4

54
36

72

200

VW3A7606R07a
VW3A7606R30a

0.75
3

203.00
261.00

ATV32HU55N4…HU75N4

27

27

400

VW3A7604R07a
VW3A7604R30a

0.75
3

270.00
333.00

a

Discount Schedule for this product is PC51.

IP 20 Rated Dynamic Braking Resistors for the Altivar 32
For use with high inertia motor loads, generating motor mode loads and machines with fast cycle times. See Altivar 32
Installation Manual for sizing information
Table 32:

Altivar 32 IP 20 Rated Dynamic Breaking Resistors

For Use On

VW3 A7 701

Resistor Description
Ohmic Value: Average Power
Available at 50 °C

Minimum Resistor Value to
Connect to the Drive: ohms

ohms

watts

Catalog Number

$ Price

ATV32H018M2…H075M2
ATV32HU11M2…HU15M2
ATV32H037N4…H075N4
ATV32HU11N4…HU30N4
ATV32HU40N4

40
27
80
54
36

100

50

VW3A7701

ATV32HU22M2
ATV32HU55N4…HU75N4

25
27

60

100

VW3A7702

785.00

ATV32HD11N4…HD15N4

18

28

200

VW3A7703

1165.00

575.00

EMC Input Filters for the Altivar 32
Maximum length in meter of shielded cable between drive and motor in reference to IEC 61800-3.
Category 1 (C1) is for residential limits Category 2 (C2) is for industrial limit
Table 33:

Altivar 32 EMC Input Filters
Filter Mounts

Heat Loss
Watts

Nominal
Current Amps

Category C1
m

Category C2
m

Catalog Number

ATV32H018M2
ATV32H037M2
ATV32H055M2
ATV32H075M2

on side of drive

3.7

10.1

20

50

VW3A4420

ATV32HU11M2
ATV32HU15M2

on side of drive

6.9

17.6

20

50

VW3A4421

95.00

ATV32HU22M2

on side of drive

7.5

23.9

20

50

VW3A4426

120.00

ATV32H037N4
ATV32H055N4
ATV32H075N4
ATV32HU11N4
ATV32HU15N4

on side of drive

9.5

15

20

50

VW3A4422

79.00

ATV32HU22N4
ATV32HU30N4
ATV32HU40N4

on side of drive

15.8

25

20

50

VW3A4423

120.00

ATV32HU55N4
ATV32HU75N4

underneath drive

19.3

47

20

50

VW3A4424

145.00

ATV32HD11N4
ATV32HD15N4

underneath drive

27.4

49

20

50

VW3A4425

175.00

For Use On

VW3A4422

VW3A4424

$ Price

79.00

Output Motor Filters for the Altivar 32
Motor filters can be installed between the Altivar 32 and the motor to: • limit the dV/dt at the motor terminals • filter
interference • reduce leakage current • filter the current wave form to create a smoother wave form to reduce motor
noise. This listing is a global offer. See page 64 of this document for additional filters available in the USA.
Table 34:

Altivar 32 Output Motor Filters
For Use On

ATV32HU22M2
ATV32HU22N4…HU40N4
ATV32HU55N4
ATV32HU75N4…HD11N4
ATV32HD15N4
a

40

Heat Loss
Watts

Nominal
Current Amps

75
65
75
90
80

16
10
16
30
60

Cable Length
Shielded
m

<100

Unshielded
m

<200

Catalog Number
VW3A4553a
VW3A4552a
VW3A4553a
VW3A4554a
VW3A4555a

$ Price
1489.00
1379.00
1489.00
1720.00
2085.00

Discount Schedule for this product is PC51.

CP4B PC51a Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drive Products
Altivar™ 32 Drives

Table 35:

Altivar™ 32 Options and Accessories
Description

For Use On

Catalog Number

$ Price

Software
SoMove™ PC software enables the user to configure, set, diagnose and maintain the Altivar 32 drive. The ATV Logic and Safety functions embedded in the Altivar
32 drive must be configured with this software. The software can also be used to customize the integrated display terminal menus. It can be used with a direct
connection or a Bluetooth® wireless connection. Free download www.schneider-electric.us
Cable to connect PC to Altivar 32
USB/RS485 cord set (equipped with RJ45 socket)

TCSMCNAM3M002P

52.00

VW3A1006b
VW3A1007b

65.00
65.00

Remote Display Keypad and cables
Remote LED Display Keypad Description: 4 digit, 8 keys, 50 °C rated
IP54 keypad, also select remote keypad cable below
IP65 keypad, also select remote keypad cable below

Altivar 12 & Altivar 32

Remote Keypad Cables—Equipped with 2 RJ45 Connectors
1 meter length

VW3A1006

Altivar & Altistart™ motor
starters

VW3A1104R10

35.00

VW3A1104R30

35.00

Altivar 212, 312, 32, 61, & 71

VW3A1101

115.00

IP54 rated kit for remote mounting LCD Graphical keypad on enclosure door

VW3A1101

VW3A1102

55.00

Clear plastic door for use with kit VbW3A1102 for IP65 rating and tamper resistance

VW3A1102

VW3A1103

35.00

Female / Female right angle RJ45 adaptor, to connect cable and keypad.a

VW3A1101

VW3A1105

35.00

3 meter length
Remote LCD Graphic Display Keypad, cables and accessories
Remote LCD Graphical Display Keypad Description:
8 line, 24 characters per line, plain text, 8 keys, rotary wheel, 600 °C IP54 rated
Remote LCD Graphical Keypad Mounting accessories

VW3A1101

Remote Keypad Cables—Equipped with 2 RJ45 Connectors
1 meter length

VW3A1101

VW3A1104R10

35.00

3 meter length

VW3A1101

VW3A1104R30

35.00

5 meter length

VW3A1101

VW3A1104R50

35.00

10 meter length

VW3A1101

VW3A1104R100

35.00

Modbus™ Serial Link—Connection via splitter box and RJ45 connectors
Length
Modbus splitter box (with 10 RJ45 Connectors)

VW3A1102
VW3A1103
VW3A1101
VW3A1104R10

Cordsets for Modbus serial link (with 2 RJ45 connectors

Modbus T-junction boxes (with integrated cables)
RJ45 Line Terminators (Sold in lots of 2)

—

LU9GC3a

312.00

.3 m

LU9GC3

VW3A8306R03b

20.00

1m

LU9GC3

VW3A8306R10b

25.00

3m

LU9GC3

VW3A8306R30b

30.00

.3 m

LU9GC3

VW3A8306TF03b

75.00

1m

LU9GC3

VW3A8306TF10b

85.00

—

LU9GC3

VW3A8306RCb

6.00

Altivar 12, 312, 32, 61, 71

Configuration Loaders—Use to Upload Download and store drive configuration settings
Simple Loader—Using RJ45 port on product, one product configuration can be downloaded from
a product, stored & uploaded to similar products. Cable included.

VW3A8120

175.00

Multi-Loader—Multiple product configurations can be downloaded from a PC or drive, stored on Altivar 12, 212, 312, 32, 61, 71
an SD card and uploaded to similar products.
Altistart 22

VW3A8121

350.00

Multi-loader Cable. Fitted with non-locking RJ45 connector and handle to reach into Altivar 12 &
Altivar 32 packaging.

VW3A8121

VW3A8126

30.00

Altivar 32

ATVPOT25K

69.00

Operator Interface

Multi-loader

Operator, mounting collar, 2.5 kilohm, 1⁄2 watt potentiometer
a
b

Not required if using VW3A1102.
Discount Schedule for this product is CP4B.

Table 36:
Altivar 32 Replacement Cooling Fans
These replacement cooling fans have a quick connect connector and snap into the Altivar 32.
Description

For Use On
ATV32H018M2...075M2
ATV32H037N4...HU15N4

Replacement Cooling Fansc

c

Reference Number
VZ3V32A100

$ Price
75.00

ATV32HU11M2...U22M2
ATV32HU22N4...HU40N4

VZ3V32B100

85.00

ATV32HU55N4...ATV32U75N4

VZ3V32C100

105.00

ATV32HD11N4...HD15N4

VZ3V32D100

135.00

Available 2nd Quarter 2012.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

PC51 CP4Bb CP1G

CP4C

Discount
Schedule

41

Pricing Guide

AC Drive Products
Altivar™ 71 Drives

Altivar™ 71 Single-Phase
In an application where it is necessary to use a 240 V single-phase input for a 3-phase motor, the drive must be derated;
therefore, the power listed on the drive nameplate will be higher than the power rating on the motor nameplate.
For more information on wire and line reactor sizing, refer to Altivar 61 and 71 Supplementary Ratings (30072-451-38).
Table 37:

Altivar 71 Selection and Pricing
With a 5% Line
Reactor

Motor
Power

Continuous
Output
Current

Without a Line Reactor
Motor
Power

Continuous
Output
Current

Input
Line
Voltage

Price $

a

b
c

Catalog Number
with LCD Keypadb

Price $

Price $
Catalog Number
with LED
Keypad
(Non-stocked)

HP kW

A

HP

kW

—

—

—

0.5

0.37

3

ATV71H075M3a

652.00

ATV71H075M3T1

697.00

ATV71H075M3Za

557.00

—

—

—

1

0.75

4.8

ATV71HU15M3a

694.00

ATV71HU15M3T1

729.00

ATV71HU15M3Za

589.00

—

—

—

2

1.5

8

ATV71HU22M3a

796.00

ATV71HU22M3T1

841.00

ATV71HU22M3Za

701.00

—

—

—

3

2.2

11

ATV71HU30M3a

984.00

ATV71HU30M3T1

1029.00

ATV71HU30M3Za

889.00

—

3

13.7

—

—

—

ATV71HU40M3a

1150.00

ATV71HU40M3T1

1195.00

ATV71HU40M3Za

1055.00

17.5

—

—

—

ATV71HU55M3a

1458.00

ATV71HU55M3T1

1503.00

ATV71HU55M3Za

1363.00

27.5

5

4

17.5

ATV71HU75M3a

1790.00

ATV71HU75M3T1

1835.00

ATV71HU75M3Za

1695.00

5
4
208/
240 Vac 7.5 5.5
Single
Phase 10 7.5

A

Catalog Number
to have ATV71 and
Type 1 conduit entry
kit shipped as
one line item. Field
installation required
(Packaged as kit at
warehouse).

33

7.5

5.5

27.5

ATV71HD15M3Xac 2850.00

ATV71HD15M3XT1c

2895.00

—

—

—

10

7.5

33

ATV71HD18M3Xac 3422.00

ATV71HD18M3XT1c

3487.00

—

—

15

11

54

—

—

—

ATV71HD22M3Xac 4170.00

ATV71HD22M3XT1c

4253.00

—

—

ATV71HD15M3XZa 2755.00

20

15

66

15

11

54

ATV71HD30M3Xac 5348.00

ATV71HD30M3XT1c

5433.00

—

—

25

18

75

20

15

66

ATV71HD37M3Xac 6212.00

ATV71HD37M3XT1c

6297.00

—

—

30

22

88

25

18

75

ATV71HD45M3Xac 7356.00

ATV71HD45M3XT1c

7491.00

—

—

Option to have product treated for increased protection for dusty and corrosive environments. This product is not stocked. On 0.5 hp to 5 hp at 230 Vac
single-phase, add “S337” to the end of the catalog number. On 7.5 hp to 25 hp at 230 Vac single-phase, add “337” to the end of the catalog number. In
both cases multiply price by 1.2 to obtain new price. With this option, exposed copper is tinned, circuit boards are conformal coated in critical areas and
plastics are treated to better withstand the corrosive nature of certain oils.
These products can be ordered with LonWorks® or BACnet communication option card shipped as one line item. Field installation required. Add “LW” to
the end of the part number to receive a LonWorks option card. Add $550 to the price. Add “BN” to the end of the part number to receive a BACnet option
card. Add $225 to the price.
Product does not contain an EMC filter.

Altivar 71 Three-Phase
Table 38:

Altivar 71 Selection and Pricing
Constant Torque

Input
Line
Voltage

LCD Keypad
208/240 Vac
Three
Phase

a

b
c
d

Three-Phase
Motor Power

Continuous
Output
Current
$ Price

HP

kW

A

0.5
1
2
3
4
5
7.5
10
15
20
25
30
40
50
60
75
100

0.37
0.75
1.5
2.2
3
4
5.5
7.5
11
15
18
22
30
37
45
55
75

3
4.8
8
11
13.7
17.5
27.5
33
54
66
75
88
120
144
176
221
285

$ Price
Catalog Number
ATV71 drive and Type 1
conduit entry kit

ATV71H037M3a
ATV71H075M3a
ATV71HU15M3a
ATV71HU22M3a
ATV71HU30M3a
ATV71HU40M3a
ATV71HU55M3a
ATV71HU75M3a
ATV71HD11M3Xab
ATV71HD15M3Xab
ATV71HD18M3Xab
ATV71HD22M3Xab
ATV71HD30M3Xab
ATV71HD37M3Xab
ATV71HD45M3Xab
ATV71HD55M3Xbcd
ATV71HD75M3Xbcd

616.00
652.00
684.00
796.00
984.00
1150.00
1458.00
1790.00
2270.00
2850.00
3422.00
4170.00
5348.00
6212.00
7356.00
8870.00
10658.00

ATV71H037M3T1
ATV71H075M3T1
ATV71HU15M3T1
ATV71HU22M3T1
ATV71HU30M3T1
ATV71HU40M3T1
ATV71HU55M3T1
ATV71HU75M3T1
ATV71HD11M3XT1b
ATV71HD15M3XT1b
ATV71HD18M3XT1b
ATV71HD22M3XT1b
ATV71HD30M3XT1b
ATV71HD37M3XT1b
ATV71HD45M3XT1b
ATV71HD55M3XT1b
ATV71HD75M3XT1b

$ Price
Catalog Number
with LED Keypad
(Non-stocked)

661.00
697.00
729.00
841.00
1029.00
1195.00
1503.00
1835.00
2315.00
2895.00
3487.00
4235.00
5433.00
6297.00
7491.00
9330.00
11211.00

ATV71H037M3Za
ATV71H075M3Za
ATV71HU15M3Za
ATV71HU22M3Za
ATV71HU30M3Za
ATV71HU40M3Za
ATV71HU55M3Za
ATV71HU75M3Za
ATV71HD11M3XZab
ATV71HD15M3XZab
—
—
—
—
—
—
—

521.00
557.00
589.00
701.00
889.00
1055.00
1363.00
1695.00
2175.00
2755.00
—
—
—
—
—
—
—

Option to have product treated for increased protection for dusty and corrosive environments. This product is not stocked. On 0.5 hp to 10 hp at 230 Vac
3 phase and up to 100 hp at 460 V, add “S337” to the end of the catalog number. On 15 hp to 60 hp at 230 Vac 3 phase, add “337” to the end of the
catalog number. In both cases multiply price by 1.2 to obtain new price. With this option, exposed copper is tinned, circuit boards are conformal coated
in critical areas and plastics are treated to better withstand the corrosive nature of certain oils. This option is standard on 55 kW/75 hp @ 230 Vac 3 phase
and higher & 90 kW/125 hp @ 460 Vac and higher.
Product does not contain an EMC filter.
Product ships with a DC choke that must be field mounted. A 5% line reactor may be purchased and installed in place of the DC choke. Add “D” to the
end of the catalog number to receive just the AC drive and multiply the listed price by.96 to obtain new price.
Conformal coating is standard.

LED Keypad

42

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drive Products
Altivar™ 71 Drives

Altivar™ 71 Selection and Pricing (continued)
Constant Torque
Three-Phase Continuous
Output
Motor Power
Current
Input
Line
Voltage

$ Price

$ Price
Catalog Number
to have ATV71 drive and
Type 1 conduit entry kit
shipped as one line item.
Field installation required
(Packaged as kit at
warehouse).

$ Price
Catalog Number
with LED Keypad
(Non-stocked)

HP

kW

A

Catalog Number
with LCD Keypad
(Stocked)

400/480 Vac
Three
Phase

1
2
3
4
5
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
400
450
500
600
700

0.75
1.5
2.2
3
4
5.5
7.5
11
15
18
22
30
37
45
55
75
90
110
130
160
200
250
280
310
400
500

2.3
4.1
5.8
7.8
10.5
14.3
17.6
27.7
33
41
48
66
79
94
116
160
179
215
259
314
387
481
550
616
759
941

ATV71H075N4ac
ATV71HU15N4ac
ATV71HU22N4ac
ATV71HU30N4ac
ATV71HU40N4ac
ATV71HU55N4ac
ATV71HU75N4ac
ATV71HD11N4ac
ATV71HD15N4ac
ATV71HD18N4ac
ATV71HD22N4ac
ATV71HD30N4ac
ATV71HD37N4ac
ATV71HD45N4ac
ATV71HD55N4ac
ATV71HD75N4ac
ATV71HD90N4bc
ATV71HC11N4bc
ATV71HC13N4bc
ATV71HC16N4bc
ATV71HC20N4bcf
ATV71HC25N4bcf
ATV71HC28N4bcf
ATV71HC31N4bcf
ATV71HC40N4bcf
ATV71HC50N4bcf

794.00
912.00
1110.00
1250.00
1316.00
1584.00
1924.00
2278.00
2832.00
3408.00
3710.00
4566.00
5370.00
6742.00
7762.00
8862.00
9742.00
11002.00
12642.00
14282.00
16462.00
19382.00
23002.00
27922.00
37392.00
52041.00

ATV71H075N4T1
ATV71HU15N4T1
ATV71HU22N4T1
ATV71HU30N4T1
ATV71HU40N4T1
ATV71HU55N4T1
ATV71HU75N4T1
ATV71HD11N4T1
ATV71HD15N4T1
ATV71HD18N4T1
ATV71HD22N4T1
ATV71HD30N4T1
ATV71HD37N4T1
ATV71HD45N4T1
ATV71HD55N4T1
ATV71HD71N4T1
ATV71HD90N4T1
—
—
—
—
—
—
—
—
—

839.00
957.00
1155.00
1295.00
1361.00
1629.00
1969.00
2323.00
2877.00
3453.00
3775.00
4631.00
5435.00
6877.00
7897.00
8997.00
10202.00
—
—
—
—
—
—
—
—
—

ATV71H075N4Za
ATV71HU15N4Za
ATV71HU22N4Za
ATV71HU30N4Za
ATV71HU40N4Za
ATV71HU55N4Za
ATV71HU75N4Za
ATV71HD11N4Za
ATV71HD15N4Za
ATV71HD18N4Za
ATV71HD22N4Za
ATV71HD30N4Za
ATV71HD37N4Za
ATV71HD45N4Za
ATV71HD55N4Za
ATV71HD75N4Za
—
—
—
—
—
—
—
—
—
—

699.00
817.00
1015.00
1155.00
1221.00
1489.00
1829.00
2183.00
2737.00
3313.00
3615.00
4471.00
5275.00
6647.00
7667.00
8767.00
—
—
—
—
—
—
—
—
—
—

575/690 Vac
Three
Phase

2
3
4
5
7.5
10
15
20
25
30
40
50
60
75
100
125
150
175
200
250
350
450
550
700

2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
400
500
630

2.7
3.9
5.8
6.1
9
11
17
22
27
32
41
52
62
77
99
125
150
180
220
290
355
420
543
675

ATV71HU22Yd
ATV71HU30Yd
ATV71HU40Yd
ATV71HU55Yd
ATV71HU75Yd
ATV71HD11Yd
ATV71HD15Yd
ATV71HD18Yd
ATV71HD22Yd
ATV71HD30Yd
ATV71HD37Yd
ATV71HD45Yd
ATV71HD55Yd
ATV71HD75Yd
ATV71HD90Yd
ATV71HC11Yde
ATV71HC13Yde
ATV71HC16Yde
ATV71HC20Ydef
ATV71HC25Ydef
ATV71HC31Ydef
ATV71HC40Ydef
ATV71HC50Ydef
ATV71HC63Ydef

1889.00
1990.00
2009.00
2380.00
2799.00
3380.00
3979.00
4790.00
5780.00
6999.00
8579.00
10379.00
12199.00
14399.00
16899.00
19179.00
23795.00
24290.00
28950.00
35950.00
46750.00
59590.00
78490.00
103390.00

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

ATV71HC28N4

ATV71HC31Y
a

b
c
d
e
f

Option to have product treated for increased protection for dusty and corrosive environments. This product is not stocked. Up to 100 hp at 460 V, add
“S337” to the end of the catalog number and multiply price by 1.2 to obtain new price. With this option, exposed copper is tinned, circuit boards are
conformal coated in critical areas and plastics are treated to better withstand the corrosive nature of certain oils. This option is standard on
90 kW/125 hp @ 460 Vac and higher.
Product ships with a DC choke that must be field mounted. A 5% line reactor may be purchased and installed in place of the DC choke. Add “D” to the
end of the catalog number to receive just the AC drive and multiply the listed price by.96 to obtain new price.
Also possible for use with a synchronous motor. Add “383” to the end of the catalog number and multiply the listed price by 1.2 to obtain new price.
Conformal coating is standard.
An AC 5% line reactor is mandatory.
These products do not contain a dynamic braking transistor. A separate transistor must be added for applications requiring dynamic braking.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

43

Pricing Guide

AC Drive Products
Altivar™ 61 and Altivar 71 Drives
Table 39:

2
3

Options—Field Installed
Description

1

4

Operator
Interface

LCD Keypad
Mounting Kits
PowerSuite™
Software
Options
Universal
Bluetooth
Interfacec
PC Cable for
Test and
Commissioning
I/O Adaptor

Option Card Assembly

I/O Extension
Option Cards

CANopen
Adapter
CANopen
Connector

Incremental
Encoder
Interface
Option Cards

I/O Option Card

Communication
Option Cards

Communication
Option Card
IMC Option
Card
Controller
Inside
Option Card
Water Solutions
Control Card

Incremental
Encoder Interface
Option Card

44

LCD graphic keypad: IP54 rating
Remote mounting kit: includes bezel and mounting hardware
Door for use with remote mount kit for IP65 rating
1 meter
Cable for remote mounting LCD graphic
3 meters
keypad
5 meter
RJ-45 connector on each end
10 meters
RJ-45 female—female adaptor to connect LCD keypad and cable. Not
required if using VW3A1102.
Operator, mounting collar, 2.5 kilohm, 1⁄2 watt potentiometer
PowerSuite software on CD for PC
USB to RJ45 adaptor: for use in connecting to a PC with a USB port
Bluetooth connectivity to devices through serial RS-485, RJ45 Modbus
port. For permanent installation, to be used during commissioning,
maintenance and troubleshooting of equipment.
Software Includes 3-meter (9.8 ft.) cable,
RS-485/RS-232C adaptor and connectors
115 Vac logic input adaptor adapts 7 logic inputs for use with
user supplied 115 Vac signals
Basic I/O option card—4 logic inputs, 2 logic outputs, 1 Form C relay
output, an input for PTC motor probes, a 24 Vdc output, a—10 Vdc
output
Extended I/O option card—contains all the I/O on the Basic I/O option
card plus 2 analog inputs, 2 analog outputs, 1 pulse input
This adaptor connects to the RJ-45 port and provides a 9–pin male
SUB–D connector conforming to the CANopen standard
(CIA DRP 303–1)
9-pin female SUB–D with line terminator (can be disabled). 180º cable
outlet CAN–H, CAN–L, CAN–GND connection
with RS-422 outputs, 5 Vdc
with RS-422 outputs, 15 Vdc
with open collector outputs, 12 Vdc
with open collector outputs, 15 Vdc
with push–pull outputs, 12 Vdc
with push–pull outputs, 15 Vdc
with push–pull outputs, 24 Vdc
Resolver
Universal with SinCos, SinCos Hiperface®, SinCos EnDat® or SSI output
incremental with RS422 outputs and encoder emulation
Modbus Plus card (limited availability)
Modbus / Uni-Telway™ card
Modbus TCP/IP Daisy Chain
Interbus® S card
Profibus DP card
Profibus DPv1 card
DeviceNet™ card
Ethernet/IP™ card
FIPIO™ card (limited availability)
LonWorks® card
Metasys® N2 card
Apogee® FLN P1 card
BACnet card with female sub D 9 pin connector (limited availability)
BACnet card with removable 4 position screw terminal connector
ATV IMC drive controller cardc

For Use on Drives

any ATV61
any ATV71

Catalog No.

$ Price

VW3A1101
VW3A1102
VW3A1103
VW3A1104R10
VW3A1104R30
VW3A1104R50
VW3A1104R100

115.00
55.00
45.00
35.00
35.00
35.00
45.00

VW3A1105

35.00

Altivar 71
Altivar™ AC drives
Altistart™ 48
TeSys™ U-line

ATVPOT25K
VW3A8104

69.00
150.00

TCSMCNAM3M002P

52.00

Altivar 12, 212, 312, 61, 71
Altistart 22

TCSWAAC13FB

180.00

ATV58 all types

VW3A8106

75.00

any ATV61
any ATV71

VW3A3101

195.00

VW3A3201

165.00

VW3A3202

195.00

any ATV61
any ATV71

VW3CANA71

45.00

any ATV61
any ATV71

VW3CANKCDF180T

45.00

VW3A3401
VW3A3402
VW3A3403
VW3A3404
VW3A3405
VW3A3406
VW3A3407
VW3A3408a
VW3A3409a
VW3A3411a
VW3A3302
VW3A3303
VW3A3310D
VW3A3304
VW3A3307
VW3A3307S371
VW3A3309
VW3A3316
VW3A3311
VW3A3312
VW3A3313
VW3A3314
VW3A3315
VW3A3319

85.00
85.00
85.00
85.00
85.00
85.00
85.00
85.00
85.00
85.00
550.00
225.00
275.00
550.00
550.00
550.00
225.00
275.00
550.00
550.00
225.00
225.00
225.00
225.00

VW3A3521S0d

755.00

any ATV61
any ATV71

any ATV71

any ATV61
any ATV71

any ATV61

Programmable option card, conforms with IEC61131–3 programming
any ATV61
standard. (Software for this option card is available after completing
VW3A3501b
any ATV71
training class offered by Schneider Electric Services.)
This option card contains a variety of pre-programmed functions and
any ATV61
VW3A3503b
features to manage multi–pump installations.
any ATV71
Using RJ45 port connections, the configurations of a drive can be
Simple Loader
ATV31,
ATV61
and
ATV71
VW3A8120
downloaded then uploaded to compatible drive.
a
For use with the ATV71H...383 drive ONLY.
b
The drive cannot support the VW3A3503 water solutions card and the VW3A3501 controller inside option card simultaneously.
c
SoMachine is required to use this product.
d
Discount Schedule for this product is PC41.
a

CP4C PC41d Discount
Schedule

550.00
650.00
175.00

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drive Products
Altivar™ 61 and Altivar 71 Drives

Table 39:

Options—Field Installed (continued)
Description

Fan Kit

Installation of kit enables the drive to operate in higher ambient
temperatures. Fan mounts on drive. Consult the product catalog for
more information.

For Use on Drives

Catalog No.

ATV61/71HD18M3X...HD22M3X,
ATV61/71HD22N4
ATV61/71HD30N4...HD37N4

VW3A9404

$ Price
135.00

VW3A9405

145.00

ATV61/71HD30M3X...HD45M3X
ATV61/71HD45N4...HD75N4

VW3A9406
VW3A9407

165.00
195.00

ATV61: Options and Accessories—Variable Torque Applications
Description

ATV58 Drive

Replaced by

ReferenceMounting
Plate

$ Price

Single-phase supply voltage: 200…240 V 50/60 Hz
ATV58HU09M2ZU
ATV58HU18M2ZU
ATV58HU29M2ZU
ATV58HU41M2ZU
ATV58HU72M2ZU
ATV58HU90M2ZU
ATV58HD12M2ZU

ATV61H075M3
ATV61HU15M3
ATV61HU22M3
ATV61HU30M3
ATV61HU40M3
ATV61HU55M3
ATV61HU75M3

VW3A9301
VW3A9301
VW3A9303
VW3A9303
VW3A9304
VW3A9306
VW3A9307

83.00
83.00
83.00
83.00
93.00
133.00
133.00

VW3A9302
VW3A9303
VW3A9304
VW3A9304
VW3A9306
VW3A9307
VW3A9309
VW3A9309
VW3A9310
VW3A9312
VW3A9312
VW3A9312

83.00
83.00
93.00
93.00
133.00
133.00
170.00
170.00
170.00
337.00
337.00
337.00

VW3A9302
VW3A9302
VW3A9302
VW3A9304
VW3A9305
VW3A9305
VW3A9307
not available
VW3A9308
VW3A9310
VW3A9310
VW3A9310
VW3A9312
VW3A9312
VW3A9312

83.00
83.00
83.00
93.00
93.00
93.00
133.00
—
138.00
170.00
170.00
170.00
337.00
337.00
337.00

Three-phase supply voltage: 200…240 V 50/60 Hz
ATV58HU29M2ZU
ATV58HU41M2ZU
ATV58HU54M2ZU
ATV58HU72M2ZU
ATV58HU90M2ZU
ATV58HD12M2ZU
ATV58HD16M2XZU
ATV58HD16M2XZU
ATV58HD23M2XZU
ATV58HD28M2XZU
ATV58HD33M2XZU
ATV58HD46M2XZU

ATV61HU15M3
ATV61HU22M3
ATV61HU30M3
ATV61HU40M3
ATV61HU55M3
ATV61HU75M3
ATV61HD11M3X
ATV61HD15M3X
ATV61HD18M3X
ATV61HD22M3X
ATV61HD30M3X
ATV61HD37M3X

Three-phase supply voltage: 380…480 V 50/60 Hz

Mounting
Plate Kit

Kit includes: Mechanical adaptors required
for mounting and Altivar™ 61/71 drive in the
place of an Altivar 58 or Altivar 58F drive
using same holes.

ATV58HU18N4ZU
ATV58HU29N4ZU
ATV58HU41N4ZU
ATV58HU54N4XZU
ATV58HU72N4XZU
ATV58HU90N4XZU
ATV58HD12N4XZU
ATV58HD16N4XZU
ATV58HD23N4XZU
ATV58HD28N4XZU
ATV58HD33N4XZU
ATV58HD46N4XZU
ATV58HD54N4XZU
ATV58HD64N4XZU
ATV58HD79N4XZU

ATV61H075N4
ATV61HU15N4
ATV61HU22N4
ATV61HU40N4
ATV61HU55N4
ATV61HU75N4
ATV61HD11N4
ATV61HD15N4
ATV61HD18N4
ATV61HD22N4
ATV61HD30N4
ATV61HD37N4
ATV61HD45N4
ATV61HD55N4
ATV61HD75N4

ATV71: Options and Accessories—Constant Torque Applications
ATV58 Drive

Replaced by

ReferenceMounting
Plate

$ Price

Single-phase supply voltage: 200…240 V 50/60 Hz
ATV58HU09M2ZU
ATV58HU18M2ZU
ATV58HU29M2ZU
ATV58HU41M2ZU
ATV58HU72M2ZU
ATV58HU90M2ZU
ATV58HD12M2ZU

ATV71H075M3
ATV71HU15M3
ATV71HU22M3
ATV71HU30M3
ATV71HU40M3
ATV71HU55M3
ATV71HU75M3

VW3A9301
VW3A9301
VW3A9303
VW3A9303
VW3A9304
VW3A9306
VW3A9307

83.00
83.00
83.00
83.00
93.00
133.00
133.00

VW3A9302
VW3A9303
VW3A9304
VW3A9304
VW3A9306
VW3A9307
VW3A9309
VW3A9309
VW3A9312
VW3A9312
VW3A9312

83.00
83.00
93.00
93.00
133.00
133.00
170.00
170.00
337.00
337.00
337.00

VW3A9302
VW3A9302
VW3A9302
VW3A9304
VW3A9304
VW3A9305
VW3A9306
VW3A9307
VW3A9308
VW3A9309
VW3A9310
VW3A9310
VW3A9312
VW3A9312
VW3A9312

83.00
83.00
83.00
93.00
93.00
93.00
133.00
133.00
138.00
170.00
170.00
170.00
337.00
337.00
337.00

Three-phase supply voltage: 200…240 V 50/60 Hz
ATV58HU29M2ZU
ATV58HU41M2ZU
ATV58HU54M2ZU
ATV58HU72M2ZU
ATV58HU90M2ZU
ATV58HD12M2ZU
ATV58HD16M2XZU
ATV58HD23M2XZU
ATV58HD28M2XZU
ATV58HD33M2XZU
ATV58HD46M2XZU

ATV71HU15M3
ATV71HU22M3
ATV71HU30M3
ATV71HU40M3
ATV71HU55M3
ATV71HU75M3
ATV71HD11M3X
ATV71HD15M3X
ATV71HD18M3X
ATV71HD22M3X
ATV71HD30M3X

Three-phase supply voltage 380…480 V 50/60 Hz

a
b

ATV58HU18N4ZU
ATV58HU29N4ZU
ATV58HU41N4ZU
ATV58HU54N4ZU
ATV58HU72N4ZU
ATV58HU90N4ZU
ATV58HD12N4ZU
ATV58HD16N4ZU
ATV58HD23N4ZU
ATV58HD28N4ZU
ATV58HD33N4ZU
ATV58HD46N4ZU
ATV58HD54N4ZU
ATV58HD64N4ZU
ATV58HD79N4ZU
Verify motor/drive ratings and application for proper replacement selections.
Catalog number may or may not contain an “X” in this position.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

ATV71H075N4
ATV71HU15N4
ATV71HU22N4
ATV71HU30N4
ATV71HU40N4
ATV71HU55N4
ATV71HU75N4
ATV71HD11N4
ATV71HD15N4
ATV71HD18N4
ATV71HD22N4
ATV71HD30N4
ATV71HD37N4
ATV71HD45N4
ATV71HD55N4

45

Pricing Guide

AC Drive Products
Altivar™ 61 and Altivar 71 Drives
Table 39:

3

Options—Field Installed (continued)
Description

1
3
1

4

2

6

5

Flange Kit VW3A9506
Flange Kit

Kit includes:
a metal frame, seals, mounting hardware, and
bracket to mount fan kit so fan can be accessed
from the front of the drive template.
Kit used to mount the heatsink of the drive outside
of an enclosure.

Type 1
Conduit Kit

Profibus
Option Card
Cover

a

46

Kit includes:
a metal box, with conduit knockouts
Kit provides conduit landing when wall mounting
the drive

For Use on Drives
ATV61/71H037M3...HU15M3
ATV61/71H075N4...HU22N4
ATV61/71HU22M3...HU40M3
ATV61/71HU30N4...HU40N4
ATV61/71HU55M3
ATV61/71HU55N4, HU75N4
ATV61/71HU75M3
ATV61/71HD11N4
ATV61/71HD11M3X..HD15M3X
ATV61/71HD15N4, HD18N4
ATV61/71HD18M3X..HD22M3X
ATV61/71HD22N4, ATV61/71HU30Y...HD30Y
ATV61/71HD30N4, HD37N4
ATV61/71HD30M3X..HD45M3X
ATV61/71HD45N4...HD75N4, ATV61/71HD37Y...HD90Y
ATV61HD55M3X...HD75M3X
ATV61HD90N4...HC11N4
ATV71HD55M3X, ATV71HD90N4
ATV61HD90M3X, ATV61HC13N4
ATV71HD75M3X, ATV71HC11N4
ATV61HC16N4, ATV61HC20Y, ATV61/71HC11Y...HC16Y,
ATV71HC13N4
ATV61HC22N4, ATV71HC16N4
ATV61HC25N4…HC31N4
ATV61HC40Y
ATV61/71HC25Y, HC31Y
ATV71HC20N4...HC28N4
ATV71HC20Y
ATV61HC25N4…HC31N4 with VW3A7101 braking transistor
ATV61HC40Y
ATV61/71HC25Y, HC31Y
ATV71HC20N4...HC28N4 with VW3A7101 braking transistor
ATV71HC20Y
ATV61/71H037M3...HU15M3
ATV61/71H075N4...HU22N4
ATV61/71HU22M3...HU40M3
ATV61/71HU30N4...HU40N4
ATV61/71HU55M3
ATV61/71HU55N4, HU75N4
ATV61/71HU75M3
ATV61/71HD11N4
ATV61/71HD11M3X..HD15M3X
ATV61/71HD15N4, HD18N4
ATV61/71HD18M3X..HD22M3X
ATV61/71HD22N4
ATV61/71HU30Y...HD30Y
ATV61/71HD30N4, HD37N4
ATV61/71HD30M3X..HD45M3X
ATV61/71HD45N4..HD75N4
ATV61/71HD37Y...HD90Y
ATV61HD55M3X...HD75M3X
ATV61HD90N4...HC11N4
ATV71HD55M3X, ATV71HD90N4, ATV61HC11N4
ATV61HD90M3X, ATV61HC13N4
ATV71HD75M3X, ATV71HC11N4
ATV61HC16N4, ATV71HC13N4
ATV61/71HC11Y...HC16Y
ATV61HC20Y
ATV61HC22N4, ATV71HC16N4
ATV61HC25N4...ATV61HC31N4
ATV71HC20N4...HC28N4
ATV71HC20Y
ATV61/71HC25Y, HC31Y
ATV61HC40Y
ATV61HC25N4...HC31N4 with VW3A7101 braking transistor
ATV71HC20N4...HC28N4 with VW3A7101 braking transistor
ATV71HC20Y
ATV61/71HC25Y, HC31Y
ATV61HC40Y
230V Drive controllers
480V Drive controllers
ATV61H••••a
075M3
U15M3
—
U22M3
U30M3
U40M3
U55M3
—
U75M3
D11M3X
D15M3X

Type 1 cover for Profibus Option Card

ATV71H••••
037M3
075M3
U15M3
U22M3
U30M3
U40M3
U55M3
—
U75M3
D11M3X
D15M3X

ATV61H••••
075N4
U15N4
U22N4
U30N4
U40N4
—
U55N4
U75N4
D11N4
D15N4
D18N4

ATV71H••••
075N4
U15N4
U22N4
U30N4
U40N4
—
U55N4
U75N4
D11N4
D15N4
D18N4

Catalog No.

$ Price

VW3A9501

255.00

VW3A9502

279.00

VW3A9503

325.00

VW3A9504

358.00

VW3A9505

419.00

VW3A9506

438.00

VW3A9507
VW3A9508
VW3A9509

469.00
469.00
477.00

VW3A9510

500.00

VW3A9511

667.00

VW3A9512

1053.00

VW3A9513

1053.00

VW3A9514

1053.00

VW3A9515

1062.00

VW3A9201

45.00

VW3A9202

45.00

VW3A9203

45.00

VW3A9204

45.00

VW3A9205

45.00

VW3A9206

65.00

VW3A9207
VW3A9217

65.00
85.00

VW3A9208

135.00

VW3A9209

460.00

VW3A9210

553.00

VW3A9211

573.00

VW3A9212

588.00

VW3A9213

604.00

VW3A9214

604.00

VW3A9201PF

101.00

VW3A9292PF

102.00

VW3A9203PF

104.00

VW3A9204PF

107.00

VW3A9205PF

112.00

The symbol “•” indicates the part of the number that varies with controller size or rating.

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Soft Start Products
Altistart™ 01 Soft Starts

Altistart™ ATS•01N2 Soft Starts
Three-phase motors rated for 6 to 32 A at 230, 400, and 460 volts.
TeSys™ U-line compatible Full motor control solution
Soft start and soft stop

1–10 second ramp

Motor voltage

230, 400, 460

Three-phase motor

1 to 20 hp, 0.75–15 kW

Internal shorting contactor Cool, reliable operation
Application

Derate for high duty cycle, temperature > 40 °C, altitude > 1000 m
(see ATS01 Catalog 8637CT0401 for more detail)

Adjustments

Start and stop times (1–10 s) and initial (starting) voltage (30–80%)

Voltage boost (Kickstart)

Activated by BOOST logic input—full voltage for first 12 cycles of motor starting
(200 ms)

LED display

Two: “Power ON” and “Full Voltage” (up to speed)

Control inputs and outputs 2 or 3 wire control, fault relay (also for isolation contactor control), “up to speed” logic
output
Plug-in control terminals

Table 40:

Ease of wiring

ATSU01N2 Family Selection and Pricing
For use with TeSys U-line motor starter (24 Vdc control power)
Three-Phase Motor Power

A

Catalog Number

$ Price
230 V

6
9
12
22
32

ATSU01N206LT
ATSU01N209LT
ATSU01N212LT
ATSU01N222LT
ATSU01N232LT

0.75–1.1 kW
1.5 kW
2.2–3 kW
4–5.5 kW
7.5 kW

1–1.5 hp
2 hp
3 hp
5–7.5 hp
10 hp

400 V

460 V

1.5–2.2 kW
3–4 kW
5.5 kW
7.5–11 kW
15 kW

2–3 hp
5 hp
7.5 hp
10–15 hp
20 hp

133.00
152.00
175.00
219.00
300.00

NOTE: The ATSU01N2 soft start must be externally supplied with 24 Vdc control power. If this is not available,
select from the ATS01N2 table below.
The ATSU01N2 soft start is shipped with a custom ATSU01N2 to TeSys U-line power connector.
Table 41:

ATS01N2 Family Selection and Pricing
For use with TeSys U-linea, GV2, GV3, and other motor starters
Three-Phase Motor Power

A

Catalog Number

$ Price
230 V

a

400 V

460 V

6
9
12
22
32

ATS01N206LU
ATS01N209LU
ATS01N212LU
ATS01N222LU
ATS01N232LU

0.75 / 1.1 kW
1.5 kW
2.2 / 3 kW
4 / 5.5 kW
7.5 kW

1 / 1.5 hp
2 hp
3 hp
5 / 7.5 hp
10 hp

—
—
—
—
—

—
—
—
—
—

133.00
152.00
175.00
219.00
300.00

6
9
12
22
32

ATS01N206QN
ATS01N209QN
ATS01N212QN
ATS01N222QN
ATS01N232QN

—
—
—
—
—

—
—
—
—
—

1.5 / 2.2 kW
3 / 4 kW
5.5 kW
7.5 / 11 kW
15 kW

—
—
—
—
—

133.00
152.00
175.00
219.00
300.00

6
9
12
22
32

ATS01N206RT
ATS01N209RT
ATS01N212RT
ATS01N222RT
ATS01N232RT

—
—
—
—
—

—
—
—
—
—

—
—
—
—
—

2 / 3 hp
5 hp
7.5 hp
10 / 15 hp
20 hp

133.00
152.00
175.00
219.00
300.00

No separate control voltage is needed.

Table 42:

Accessory
Description

Custom power connector (between ATS01N2 and TeSys U-line motor starter)

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP1G

Discount
Schedule

Catalog No.
VW3G4104

$ Price
10.00

47

Pricing Guide

AC Soft Start Products
Altistart™ 01 Soft Starts

Altistart™ ATS01N1 Soft Starts
Single or three-phase motors rated for 3 to 12 A at 110, 208, 230, 400 and 460 volts
Soft Start (no soft stop)
Motor voltage
Three-phase motor
Single-phase motor
External control power
Internal shorting contactor
Application
Adjustments
LED display
Plug-in control terminals
Table 43:

1–5 second ramp
110, 208, 230, 400, 460
1/2 to 7.5 hp
1/4 to 2 hp
24 Vac/dc or 110–230 Vac
9 and 12 A models—cool, reliable operation
Derate for temperature > 40 °C, altitude > 1000 m
(see ATS01 Catalog 8637CT0401 for more detail)
Start time (1–5 s) and initial (starting) voltage (30–80%)
Two: “Power ON” and “Full Voltage” (up to speed)
9 and 12 A models—ease of wiring

ATS01N1 Selection and Pricing
Motor Power

A

Catalog Number

3
6
9
12
25

ATS01N103FT
ATS01N106FT
ATS01N109FT
ATS01N112FT
ATS01N125FT

Table 44:

Single-Phase
110 V

208 V

—
1/4 hp
1/3 hp
1/2 hp
—

1/4 hp
1/2 hp
1 hp
1.5 hp
—

Three-Phase
230 V

0.37 kW
0.75 kW
1.1 kW
1.5 kW
—

230 V
1/4 hp
1/2 hp
1 hp
2 hp
—

0.37–0.55 kW
0.75–1.1 kW
1.5 kW
2.2 kW
3, 4, 5.5 kW

400 kW

a

460 V

1/2 hp
1.1 kW
1–1.5 hp
2.2 kW
2 hp
4 kW
3 hp
5.5 kW
3, 4, 5.5 kW 7.5, 9, 11 kW

1–1.5 hp
2–3 hp
5 hp
7.5 hp
10–15 hp

100.00
115.00
130. 00
145. 00
240.00

Accessory
Description

DZ5 MB DIN rail (

$ Price

Catalog No.

) adaptor for 3 and 6 A models (sold only in packages of 10)

$ Price

RHZ66a

3.60

Discount Schedule I.

Altistart ATS01 Higher Horsepower Soft Starts
Three-phase motors rated for 32 to 85 A at 230, 400, 460, 575, and 690 volts.

D
2
Y
E
2
T
C
t
L
r
I
U
t
a
B
t
D
n
s
A
e
E
i
t
R AIL Al em
c
V
o
A r t pla
e
e
f
r
e
R for

Soft start and soft stop

1–25 second ramp

Motor voltage

230, 400, 460, 575, 690

Three-phase motor

10 to 75 hp, 7.5–85 kW

External control power

110 Vac

Internal shorting contactor

Cool, reliable operation

Application

Derate for high duty cycle and altitude > 2000 m.
(see ATS01 Catalog 8637CT0401 for more detail). Maximum temperature = 55 °C

Adjustments

Start and stop times (1–25 s) and initial (starting) voltage (30–80%)

LED display

“Power ON” and “Full Voltage” (up to speed)

Control inputs and outputs

2 or 3 wire control, fault relay (also for isolation contactor control),
“Up to Speed” auxiliary relay (accessory: LAD8N11)

Table 45:

ATS01N2 Selection and Pricing

Three-Phase Motor Power

A

Catalog Number

$ Price

230 V

32
44
72
85

Table 46:

ATS01N230LY
ATS01N244LY
ATS01N272LY
ATS01N285LY

7.5 kW
11 kW
18.5 kW
22 kW

460 V

575 V

690 V

15 kW
22 kW
37 kW
45 kW

20 hp
30 hp
50 hp
60 hp

30 hp
40 hp
60 hp
75 hp

30 kW
37 kW
55 kW
85 kW

613.00
799.00
1013.00
1227.00

Accessories

Description

Catalog No.

$ Price

“Up to Speed” auxiliary relay contact (attaches to side of ATS01)

LAD8N11a

20.70

DIN rail adaptor (32 and 44 A models)

VY1H4101

25.00

a

48

10 hp
15 hp
25 hp
30 hp

400 V

Discount Schedule I12.

I11

CP1G

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Soft Start Products
Altistart™ 22 Soft Starts

Altistart™ 22 Open Style Soft Starter
The Altistart 22 unit uses both voltage and torque control to provide a soft start and soft stop for three-phase
asynchronous motors between 17 and 590 amps.
Table 47:
ATS22 Selection and Pricing
Select the Altistart 22 soft start using the nameplate full-load ampere rating of the motor and the table below. The
horsepower ratings are for reference only.
Dimensions (inches)
208 V

230 V

400 kW

460 V

575 V

Rated
A

Soft Start Reference
b or c
W

H

D

Frame
Size

$ Price

3

5

5.5

10

15

17

ATS22D17S6,S6U

5.1

9.8

6.6

A

613.00

7.5

10

11

20

25

32

ATS22D32S6,S6U

5.1

9.8

6.6

A

654.00

—a

15

18.5

30

40

47

ATS22D47S6,S6U

5.1

9.8

6.6

A

786.00

15

20

22

40

50

63

ATS22D62S6,S6U

5.7

10.9

8.1

B

945.00

20

25

30

50

60

75

ATS22D75S6,S6U

5.7

10.9

8.1

B

1083.00

25

30

37

60

75

88

ATS22D88S6,S6U

5.7

10.9

8.1

B

1266.00

30

40

45

75

100

110

ATS22C11S6,S6U

5.9

13

9

C

1468.00

40

50

55

100

125

140

ATS22C14S6,S6U

5.9

13

9

C

1792.00

50

60

75

125

150

170

ATS22C17S6,S6U

5.9

13

9

C

2056.00

60

75

90

150

200

210

ATS22C21S6,S6U

8.1

15.6

11.8

D

2383.00

75

100

110

200

250

250

ATS22C25S6,S6U

8.1

15.6

11.8

D

2714.00

100

125

132

250

300

320

ATS22C32S6,S6U

8.1

15.6

11.8

D

3083.00

125

150

160

300

350

410

ATS22C41S6,S6U

8.1

15.6

11.8

D

3573.00

150

—

220

350

400

480

ATS22C48S6,S6U

11.9

16.8

13.4

E

4263.00

—

200

250

400

500

590

ATS22C59S6,S6U

11.9

16.8

13.4

E

4862.00

a
b
c

Value not indicated when there is no corresponding standardized motor.
S6 = 208–600 line voltage, 220 V control voltage
S6U = 208–600 line voltage, 110 V control voltage

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP1G

Discount
Schedule

49

Pricing Guide

AC Soft Start Products
Altistart™ 22 Soft Starts

Altistart™ Options: Fans and Accessories
Table 48:

Accessories Selection and Pricing
Description

Length

Catalog Number

$ Price

SoMove™ Lite This software enables the user to configure, set, debug and organize maintenance task for the Altistart 22 soft
starter. It can also be used to customize the integrated display terminal menus. It can be used with a direct connection or a
Bluetooth® wireless connection. Free download www.schneider-electric.us

Software
Cable

USB/RS485 cord set (equipped with RJ45 socket)

Remote
Keypada
Remote Keypad Cords
Equipped with 2 RJ45
Connectors

TCSMCNAM3M002Pb

52.00

IP54/NEMA® 12 keypad

VW3G22101b

65.00

IP65 keypad

VW3G22102b

65.00

3 FT length

VW3A1104R10b

35.00

9 FT length

VW3A1104R30b

35.00

LU9GC3c

312.00

.3 m

VW3A8306R03b

20.00

1m

VW3A8306R10b

25.00

3m

VW3A8306R30b

30.00

.3 m

VW3A8306TF03b

75.00

1m

VW3A8306TF10b

85.00

VW3A8306RCb

6.00

Modbus™ splitter box (with 10 RJ45 Connectors)

Cordsets for Modbus serial link (with 2 RJ45 connectors
Modbus Serial Link
Connection via splitter box and
RJ45 connectors
Modbus T-junction boxes (with integrated cables)
RJ45 Line Terminators (Sold in lots of 2)
a
b
c

A remote keypad cord set is required.
Discount Schedule for this product is CP1C.
Discount Schedule for this product is I11.

Table 49:

Fans Selection and Pricing

Power Supply Voltage For Control

For Use On Altistart

Catalog Number

$ Price

The ATS22C21S6,S6U..C59S6,S6U units come with an integrated fan. The ATS22D17S6,S6U..C17S6,S6U units are ventilated by means of natural ventilation.
For more demanding applications, such as those with a greater number of starts, the Altistart 22 range offers fans as an option. The fans are powered by the Altistart
22 unit and attach to the back of the device. The fan's noise level is less than 60 dBA.

220 V

110 V

Table 50:

ATS22D17..D47S6

VW3G22400

65.00

ATS22D62..D88S6

VW3G22401

65.00

ATS22C11..C17S6

VW3G22402

75.00

ATS22D17..D47S6U

VW3G22U400

65.00

ATS22D62..D88S6U

VW3G22U401

65.00

ATS22C11..C17S6U

VW3G22U402

75.00

Protection Shrouds for Power Terminals
Description

For Use On Altistart

Set of 6 power terminal protection
shrouds
d

$ Price

ATS22C11S6,S6U ..C17S6,S6U

LA9F702d

61.00

ATS22C21S6,S6U ..C59S6,S6U

LA9F703d

82.00

Discount Schedule for this product is I12.

Table 51:

50

Catalog Number

Multi-Loader Configuration Tools
Description

Catalog Number

The Multi-Loader tool enables multiple configurations from a PC (with SoMove software) or drive/soft
starter to be copied and uploaded to another drive/soft starter.

VW3A8121

CP1Cb

I11c

I12d

CP1G

Discount
Schedule

$ Price
350.00

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Soft Start Products
Enclosed Altistart™ 22 Motor Controllers

Enclosed Altistart™ 22 Motor Controllers
Enclosed Altistart 22 (ATS22) solid-state combination motor
controllers are a pre-engineered, integrated solution for
reduced voltage starting and soft stopping of standard
three-phase asynchronous induction (squirrel cage) motors.
The Enclosed 22 controllers consist of a disconnect means
and an ATS22 soft starter in a stand-alone enclosure.
Enclosed 22 controllers integrate the ATS22 soft start
technology into a combination package for application
requirements up to 125 hp at 480 V.

•
•
•

3–50 hp, 208 V
5–60 hp, 230 V
10–125 hp, 460 V

Table 52:
Field
—

01

02

Catalog Number Description

Horsepower

03

5

Enclosure
Type

04

6

Voltage

05

7

06

8–10

Control
Optionsde

07

11–13

Pilot Device
Optionsde

08

09

a
b

c
d
e
f
g
h
i
j
k

Power Circuit

A = 3 hp
B = 5 hp
C = 7.5 hp
D = 10 hp
E = 15 hp
F = 20 hp
G = 25 hp
H = 30 hp
J = 40 hp
K = 50 hp
R = 200 hp
L = 60 hp
S = 250 hp
M = 75 hp
T = 300 hp
N = 100 hp
U = 350 hp
P = 125 hp
W = 400 hp
Q = 150 hp
X = 500 hp
G = UL Type 1 General Purpose
A = UL Type 12K Industrial Use, Dust-Tight/DripTight
H = UL Type 3R Outdoor Use
2 = 208 Vac
3 = 230 Vac
4 = 460 Vac
5 = 575 Vac
B = Basic Shunt Trip
S = Full-Featured Shunt Trip
N = Non-Reversing Isolation
R = Reversing Isolation
Y = Integral Full-Voltage Bypass
A06 = Start-Stop Pushbuttons
B06 = Forward-Off-Reverse
C06 = Hand-Off-Auto (HOA) Selector Switch
D06 = Stop-Run Selector Switch
E06 = Hand-Auto Selector Switch/Start-Stop
Pushbuttons
A07 = Run Light (Red), Off Light (Green)
B07 = Push-to-Test Run Light (Red), Push-to-Test
Off Light (Green)
C07 = Run Light (Red), Off Light (Green), Tripped
Light/Reset (Yellow)
D07 = PTT Run Light (Red), PTT Off Light
(Green), Tripped Light/Reset (Yellow)

14–16

Metering
Options

17–19

A10 = Floor Mounting Kitf
B10 = Additional 150 VAg
C10 = Power-Up On Delay Relayh
D10 = Emergency Stop Pushbuttong
E10 = cUL Labela
F10 = Auxiliary Run Mode Contacts
G10 = Auxiliary FB Bypass Contactsi
H10 = Auxiliary Auto Mode Contactsj
Miscellaneous J10 = Auxiliary Trip Indication Contacts
Options
L10 = ID Engraved Nameplateg
M10 = 10 Spare Terminal Blocksg
P10 = Permanent Wire Markersg
R10 = MOV-Surge Arrestorg
U10 = Omit Door-Mounted Keypad Displayb
X10 = 50 °C Operation
Z10 = Service Entrance Ratingak
910 = American Recovery and Reinvestment Act
(ARRA) Option

Field
—
8639

1
22U
PowerPact™
Controller
ThermalClass
Magnetic
Circuit Breaker

2
C
7.5
hp

3
G

4
4

5
B

6
A06

7
A07
Type 1 460 Basic Start-Stop RunLight
(Red),
General Vac
Shunt Pushbutton Off
Light
Purpose
Trip
(Green

Option Pricing—
Phase 2 Options highlighted in green

Mod
A06

Mod
B06

Mod
C06

Mod
D06

Mod
E06

CP1G

Discount
Schedule

Start/Stop push buttons

$ Price

Provides black start and red stop push buttons
(3-wire control scheme).

132.00

Forward-Off-Reverse selector switch

$ Price

Provides three-position selector switch to select between
forward, off and reverse. Uses 2-wire control.

240.00

Hand-Off-Auto selector switch

$ Price

Provides a three-position selector switch, 2-wire control
scheme.

132.00

Stop-Run selector switch

$ Price

Provides a two-position selector switch.

132.00

Hand-Auto selector switch and Start/Stop push buttons $ Price
Provides a two-position selector switch and start/stop push
buttons (3-wire control).

264.00

Pilot Light Cluster Options (pick one)
Pilot light cluster #1
Mod
A07

Mod
C07

Mod
D07

$ Price

Consists of red “RUN” and green “OFF” pilot lights. Provides
standard red “RUN (ON)” and green “OFF” pilot lights for status 180.00
annunciation.

Pilot light cluster #2
Mod
B07

B08 = Elapsed Run Time Metere

Options E10 and Z10 cannot be used together.
If you select option U10, you must separately order the remote keypad
(VW3G22101) and cable (VW3A1104R30) to commission the soft starter.
Refer to the ATS22 User Manual, BBV51330, for serial communication
programming and control capabilities.
This option is not selectable with power circuit option B05.
Select only one option.
To omit, do not include a selection in the catalog number.
This option is available only for enclosure size D.
This option is not selectable with power circuit option B05
This option is not selectable with power circuit option B05. This option is valid
only with the following control options: C06, D06, or E06.
This option is not selectable with power circuit option B05. The contacts are
available only when power circuit option Y05 is selected.
The contacts are not available when power circuit option R05 is selected.
This option is valid only with the following control options: C06, D06, or E06.
Options E10 and Z10 cannot be ordered together.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Catalog Number Example:
863922UCG4BA06A07

Control Options (pick one)

Digit Characteristic
Description
Controller
8638 = Fused Disconnectc
—
Class
8639 = Circuit Breaker Disconnect
22F = Altistart 22 with Class J Fuse Clips and
Molded Case Switchc
Controller
22T = Altistart 22 with PowerPact Motor Circuit
1–3
Style
Protector
22U = Altistart 22 with PowerPact Thermal-

4

Table 53:

$ Price

Consists of red “RUN” (push-to-test) and green “OFF” (push-totest) pilot lights. Provides push-to-test type red “RUN (ON)” and 360.00
standard green “OFF” pilot lights for status annunciation.

Pilot light cluster #3

$ Price

Consists of red “RUN”, green “OFF” and yellow “FAULT” pilot
lights. Provides standard red “RUN (ON)” green “OFF” and
yellow “FAULT” pilot lights for status annunciation.

270.00

Pilot light cluster #4

$ Price

Consists of red “RUN (ON)” (push-to-test), green “OFF” (pushto-test) and yellow “FAULT” (push-to-reset) pilot lights. Provides 540.00
push-to-test type red “RUN (ON)” standard green “OFF”, and
push-to-reset type yellow “FAULT” for status annunciation.

Meter Display Options (pick one)
Mod
BO8

Elapsed time meter

$ Price

Provides a seven-digit analog, non-resettable elapsed run time 348.00
meter. Not available on Type 3R Enclosures

Miscellaneous Options
(multiple compatible options may be selected)
Mod
A10

Floor mounting kit

$ Price

Only available for size D enclosures.

105.00

Rules: Available for power options S05, N05, R05, Y05.
Mod
B10

150 VA additional control power capacity

$ Price

Provides 150 VA additional control VA capacity for customer
use.

150.00

51

Pricing Guide

AC Soft Start Products
Enclosed Altistart™ 22 Motor Controllers
Power up on delay (start relay)

$ Price

Mod
C10

Provides an electronic time delay relay adjustable from 0.1 to
60 seconds. Relay is pre-wired to inhibit start for users set 150.00
delay time upon power-up of control.

Mod
D10

Emergency stop push button

Mod
L10

“cUL” label

Mod
M10

$ Price

Provides a Canadian Underwriters Laboratories label when 200.00
required by local code requirements.
Auxiliary contacts for run mode

$ Price

Provides one Form A, normally open (N.O.) contact rated 5 A
at 120 Vac to the terminal blocks for customer use. The
contact closes when the controller is applying power to the 550.00
motor.

Mod
F10

Mod
G10

Auxiliary contacts for full voltage bypass run mode

$ Price

Provides 1 Form C contact rated 5 A @ 120 Vac
(8501 Type R relay or equivalent) wired to terminal blocks
for customer use. Contacts change state when motor is
operated across the line with full voltage by bypass starter.

550.00

Auxiliary contacts for auto mode

Mod
P10

Mod
R10

Mod
U10

Rules: Full Voltage Bypass must be selected. Must use Power Circuit N or R
(line isolation) contactor combination. Not compatible with Power
Circuit S (Shunt Trip)

Mod
H10

$ Price

Provides a lamacold nameplate, engraved with equipment
designation.

50.00

Spare terminal blocks

$ Price

Provides a push-button for immediate removal of all power. 140.00

Mod
E10

ID engraved nameplates

$ Price

Provides up to 10 spare terminal blocks unwired for customer
use. Since Phoenix style terminal blocks will be used, extra
terminal points will be provided as standard 20 terminal
340.00
points are available as standard for all control wiring
(including any additional customer spare terminal points).
Permanent wire markers

$ Price

Provides a permanent sleeve type wire marker on control
wiring assemblies

1400.00

MOV/Surge arrestor (custom engineered option)

$ Price

Provides supplementary MOV protection using a Class 6671
SDSA3650 Surgebreaker Secondary Surge Arrester hardwired and factory mounted.

450.00

Omit door mounted keypad display

$ Price

Omits the door-mounted keypad display. A keypad closing
plate and gasket are provided on the door.

(50.00)

Rules: To program or control the ATS22 soft starter with Modbus communication,
refer to the ATS22 User Manual, BBV51330.
Seismic qualification label

$ Price

Provides one Form A, normally open (N.O.) contact rated 5 A
@ 120 Vac to the terminal blocks for user use. The contact 550.00
closes when the controller is placed in Auto (remote) mode.

Mod
Y10

Rules:MOD C06 (Hand-Off-Auto selector switch) or E06 (Hand-Auto selector
switch) must be specified.

$ Price

Provides a self-certified identification label with compliance to
2000 IBC, NFPA 5000, 2001 CBC, 1997 UBC, 1999 NBC,
1999SBC, ASCE-7 02 seismic qualification certification. The 450.00
label criteria will be uniform for all enclosed products.
Enclosures shall contain additional bracing as defined by the
seismic qualification certification criteria.

Rules: Not available for wall mounted enclosures.
Auxiliary contacts for trip status
Mod
J10

$ Price

Provides one Form A, normally open (N.O.) contact rated 5 A
@ 120 Vac to the terminal blocks for user use. The contact 650.00
closes when the controller has tripped.

Service Entrance Rating
Mod
Z10

$ Price

Provides a UL869A approved insulated ground neutral lug
assembly, mounting bracket with bonded enclosure ground 185.00
wire suitable for use as service entrance equipment.

Rules: Service Entrance Rating is not available wit the Mod E10 (cUL Label).

Table 54:

Enclosed Altistart 22 Motor Controllers
with Circuit Breaker—60 Hz, Three-Phase, 208/230/460/575 Volts—Standard Duty (40 °C)
Circuit Breaker Power Option—Type 1 Enclosure
Maximum Horsepower

208 V

230 V

460 V

575 V

3
5
7.5
10
—
15
20
25
30
40
50
60
75
100
125
150l
—

5
7.5
10
—
15
20
25
30
40
50
60
75
100
125
150
—
200

10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400

15
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400
500

l

ShuntTrip Shunt Trip
B
S

Non-Rev
N

Reversing
Isolation
R

1400.00
1600.00
1800.00
1962.00
2124.00
2450.00
3226.00
3645.00
3944.00
4815.00
5673.00
6530.00
7387.00
8336.00
8878.00
9498.00
10740.00

1822.00
2102.00
2336.00
2563.00
2753.00
3154.00
4061.00
4557.00
4938.00
5942.00
6990.00
7937.00
8927.00
10192.00
11181.00
12170.00
13863.00

2100.00
2400.00
2677.00
2930.00
3130.00
3640.00
4624.00
5189.00
5623.00
6710.00
7895.00
8933.00
10047.00
11470.00
12563.00
13656.00
15602.00

1628.00
1870.00
2090.00
2286.00
2464.00
2832.00
3683.00
4146.00
4489.00
5438.00
6400.00
7391.00
8361.00
9310.00
10030.00
10751.00
12157.00

add
160.00
160.00
160.00
160.00
160.00
240.00
240.00
240.00
360.00
360.00
360.00
510.00
510.00
510.00
735.00
735.00
735.00

add
450.00
450.00
450.00
450.00
550.00
550.00
550.00
1000.00
1000.00
1000.00
1000.00
1450.00
1450.00
1450.00
1900.00
1900.00
—

Type 3R
add
650.00
650.00
650.00
650.00
750.00
750.00
750.00
1200.00
1200.00
1200.00
1200.00
1650.00
1650.00
1650.00
2350.00
2350.00
—

Enclosed Altistart 22 Motor Controllers
with Fusible Disconnect—60 Hz, Three-Phase, 208/230/460/575 Volts—Standard Duty (40 °C)
Fusible Power Option—Type 1 Enclosure
Maximum Horsepower

52

2190.00
2490.00
2780.00
3030.00
3280.00
3750.00
4825.00
5400.00
5888.00
7000.00
8150.00
9203.00
10337.00
11775.00
12880.00
13986.00
15947.00

40 °C Rated 50 °C Rated
Type 12
Type 1/12

50 °C Operation and Type 3R Enclosure not available.

Table 55:

208 V

230 V

460 V

575 V

3
5
7.5
10
—
15
20
25
30
40
50
60
75
100
125
150m
—

5
7.5
10
—
15
20
25
30
40
50
60
75
100
125
150
—
200

10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400

15
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400
500

m

Enclosure Rating Modifiers

Emergency
Bypass
Y

Emergency
Shunt Trip Non-Rev Reversing
Isolation
Bypass
S
N
R
Y
1705.00
1950.00
2178.00
2380.00
2558.00
2940.00
3826.00
4307.00
4663.00
5624.00
6619.00
7620.00
8620.00
9598.00
10340.00
11083.00
12532.00

1899.00
2182.00
2424.00
2657.00
2847.00
3262.00
4204.00
4718.00
5112.00
6128.00
7209.00
8183.00
9203.00
10507.00
11508.00
12509.00
14292.00

2177.00
2480.00
2765.00
3024.00
3224.00
3748.00
4767.00
5350.00
5797.00
6896.00
8114.00
9210.00
10358.00
11825.00
12952.00
14078.00
16085.00

2267.00
2570.00
2868.00
3124.00
3374.00
3858.00
4968.00
5561.00
6062.00
7186.00
8369.00
9480.00
10628.00
12095.00
13222.00
14348.00
16355.00

Enclosure Rating Modifiers
40 °C Rated
Type 12

50 °C Rated
Type 1/12

add

add

160.00
160.00
160.00
160.00
160.00
240.00
240.00
240.00
360.00
360.00
360.00
510.00
510.00
510.00
735.00
735.00
735.00

450.00
450.00
450.00
450.00
550.00
550.00
550.00
1000.00
1000.00
1000.00
1450.00
1450.00
1450.00
1450.00
1900.00
1900.00
—

Type 3R
add
650.00
650.00
650.00
650.00
750.00
750.00
750.00
1200.00
1200.00
1200.00
1650.00
1650.00
1650.00
1650.00
2350.00
2350.00
—

50 °C Operation and Type 3R Enclosure not available.

CP1G

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Soft Start Products
Altistart™ 48 Soft Starts

Altistart™ 48 Soft Starts
The Altistart 48 soft start combines ease of selection with
simple installation and high motor control performance.
With its exclusive motor Torque Control System, the
Altistart 48 helps eliminate uncontrolled motor
acceleration and deceleration, a problem inherent with
standard voltage—ramp soft starts. The Altistart 48
includes features to help with motor and machine
protection and is available for motors ranging from 208 to
575 volts. In addition to a built-in display and
programming terminal, a remote keypad option and
programming software is available to ease integration
Table 56:
Altistart 48 Selection and Pricinga

and commissioning. The Altistart 48 has a built-in
Modbus™ port and is offered with serial communication
gateways to such popular networks as Ethernet and
DeviceNet™.

Open Style Soft Starts 50–60 Hz, Three-Phase,
690 V Maximum—AC3 Duty
The Altistart 48 soft start must be selected using the table
below, based on nameplate full load ampere rating of the
motor. The horsepower ratings shown in table are for
reference only.

Standard Duty (Low Inertia Loads)b Maximum Horsepower

a
b

Altistart Soft Starts

208 V

230 V

400 kW

460 V

575 V

Rated
A

Catalog
Number

3
5
7.5
10
—
15
20
25
30
40
50
60
75
100
125
150
—
200
250
350
400

5
7.5
10
—
15
20
25
30
40
50
60
75
100
125
150
—
200
250
300
350
450

5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
220
250
315
355
400
500

10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400
500
600
800
1000

15
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400
500
600
800
1000
1200

17
22
32
38
47
62
75
88
110
140
170
210
250
320
410
480
590
660
790
1000
1200

ATS48D17Y
ATS48D22Y
ATS48D32Y
ATS48D38Y
ATS48D47Y
ATS48D62Y
ATS48D75Y
ATS48D88Y
ATS48C11Y
ATS48C14Y
ATS48C17Y
ATS48C21Y
ATS48C25Y
ATS48C32Y
ATS48C41Y
ATS48C48Y
ATS48C59Y
ATS48C66Y
ATS48C79Y
ATS48M10Y
ATS48M12Y

Motor full load amperage (FLA) must not exceed the ampere rating of
the soft start.
Low Inertia—Connected motor load inertia equal or less than 10 times
motor rotor inertia.
High Inertia—Connected motor load inertia greater than 10 times
motor rotor inertia.

Table 57:

$ Price
780.00
810.00
840.00
900.00
950.00
1200.00
1280.00
1500.00
1700.00
2100.00
2300.00
2600.00
2900.00
3300.00
3900.00
4700.00
5400.00
6200.00
7200.00
8600.00
10600.00

NOTE: For severe duty or high inertia loads, derate
by 1 hp size.

Altistart 48 Options
Description

Catalog Number

Remote Keypad Display Mounting Kit, including:
Keypad with 3–character 7–segment display
IP65 cover and seal, mounting screws, and 3 meter cable to connect keypad display to Altistart 48

$ Price

VW3G48101

165.00

Cover for power terminals—Set of 6 for ATS48C14Y and ATS48C17Y

LA9F702d

61.00

Cover for power terminals—Set of 6 for ATS48C21Y, ATS48C25Y, and ATS48C32Y

LA9F703d

Modbus Ethernet Gateway

82.00

TSXETG100e

1027.00

DeviceNet Gateway

LUFP9f

495.00

Profibus DP Gateway

LUFP7f

495.00

FIPIO™ Gateway

LUFP1f

495.00

1/3 meter connection cable (RJ–45 to RJ–45)

VW3A8306R03

20.00

1 meter connection cable (RJ–45 to RJ–45)

VW3A8306R10

25.00

3 meter connection cable (RJ–45 to RJ–45)

VW3A8306R30

30.00

1/3 meter splitter cable (For RJ—45 daisy chain connection)

VW3A8306TF03

75.00

1 meter splitter cable (For RJ–45 daisy chain connection)

VW3A8306TF10

85.00

RJ45 terminator (2 per package)

VW3A8306RC

Modbus hub (Eight RJ–45 ports)

LU9GC3f

208.00

PowerSuite™ commissioning software on CDc

VW3A8104g

150.00

PowerSuite upgrade CD from most recent to new versionc

VW3A8105g

98.00

PC connection kit. To connect PC to Altistart 48 soft startc

VW3A8106g

75.00

TCSMCNAM3M002P

52.00

VW3A8111g

95.00

USB to RJ45 Adaptor Kit
For use in connecting to a PC with a USB port
Pocket PC connection kit. To connect JORNADA™ or iPAQ™ PPC to Altistart soft startc

6.00

Size M10 Bolt Kit

W808780210111

8.00

Size M12 Bolt Kit

W808780220111

10.00

c
d
e
f
g

For more information, see Data Bulletin 8806DB0001.
Discount Schedule for this product is I12.
Discount Schedule for this product is PC41.
Discount Schedule for this product is I11.
Discount Schedule for this product is CP4C.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP1G

I12d

PC41e

I11f

For additional information on Altistart 48, reference
Catalog #8636CT0201.

CP4Cg Discount
Schedule

53

Pricing Guide

AC Soft Start Products
Enclosed Altistart 48 Soft Starts

General Information
Enclosed Altistart™ 48 Soft Starts (Enclosed 48) are available from 11 to 604 amperes in Type 1, 12 and 3R
enclosures. The Enclosed 48 soft startsoft start can provide soft startsoft starting (reduced voltage) and stopping with
deceleration control with machine and motor protection of standard NEMA® Design B squirrel cage asynchronous
motors in the following ranges:

•
•
•
•

3–200 hp, 208 V
5–250 hp, 230 V
10–500 hp, 460 V
15–600 hp, 575 V

Selection
The Enclosed 48 controller must be selected based on three main criteria:

•

AC mains voltage supply (distribution voltage):
Three-phase AC voltage: 208, 240, 480 or 600 V.
The power and the nominal motor current (FLA) indicated on the motor nameplate.
The type of application and the operating cycle. To simplify selection, applications are categorized as either standard duty or severe
duty applications. Standard or severe duty applications define the limiting values of the current and the duty cycle ratings. If severe

•
•

duty is required, select the next higher horsepower device.
Depending on the type of machine, the applications are categorized as standard or severe duty based on the starting
characteristics, which are given by example are illustrated within the table below.

Type of Machine

54

Application

Functions performed by the ATS48

Starting
Current
(% In)

Starting
Time
(secs)

Centrifugal pump

Standard

Deceleration (reduction in pressure surges)
Protection against underloads or inversion of the phase rotation direction

300

5 to 15

Piston pump

Standard

Control of running dry and direction of rotation of the pump

350

5 to 10

Fan

Standard
Detection of overloads caused by clogging or underloads (motor fan transmission
Severe if > 30 s broken) Braking torque on stopping

300

10 to 40

Cold compressor

Standard

Protection, even for special motors

300

5 to 10

Screw compressor

Standard

Protection against inversion of direction of phase rotation Contact for automatic
draining on stopping

300

3 to 20

Centrifugal compressor

Standard
Protection against inversion of direction of phase rotation Contact for automatic
Severe if > 30 s emptying on stopping

350

10 to 40

350

5 to 10

Piston compressor

Standard

Protection against inversion of direction of phase rotation Contact for automatic
emptying on stopping

Conveyor, transporter

Standard

Overload control for detecting faults or underload control for detecting breaks

300

3 to 10

Lifting screw

Standard

Overload control for detecting hard spots or underload control for detecting breaks

300

3 to 10

Drag lift

Standard

Overload control for detecting jamming or underload control for detecting breaks

400

2 to 10

Lift

Standard

Overload control for detecting jamming or underload control for detecting breaks
Constant starting with variable load

350

5 to 10

Circular saw, band saw

Standard
Severe if > 30 s Braking for fast stop

300

10 to 60

Pulper, butchery knife

Severe

Torque control on starting

400

3 to 10

Agitator

Standard

The current display indicates the density of the product

350

5 to 20

Mixer

Standard

The current display indicates the density of the product

350

5 to 10

Grinder

Severe

Braking to limit vibrations during stopping, overload control to detect jamming

450

5 to 60

Crusher

Severe

Braking to limit vibrations during stopping, overload control to detect jamming

400

10 to 40

Refiner

Standard

Torque control on starting and stopping

300

5 to 30

Press

Severe

Braking to increase the number of cycles

400

20 to 60

CP1G

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Soft Start Products
Enclosed Altistart 48 Soft Starts

Special Applications
Contact Seneca Enclosed Drives TAG for additional application information and pricing for those applications requiring:

•
•
•
•
•
•
•
•
•
•
•

Two-speed or delta-wye motors. The ATS48 soft start can operate with a 2-speed motor. A motor demagnetizing period must elapse
before changing from low speed to high speed in order to avoid anti-phase between the line supply and the motor, which would
generate very high currents.
Motors other than NEMA® Design B.
High efficiency motors.
Low slip motors.
Power factor correction capacitors. Do not connect power factor correction capacitors to the terminals of a motor controlled by an
ATS48 soft start. The power factor capacitors must be controlled and connected to a line side contactor sequenced by the ATS48 at
end of starting.
Controller oversizing of more than 50%.
Non-standard trip characteristics.
Modifications not listed in this pricing guide.
Horsepower greater than those listed in this pricing guide.
Long motor cable lengths. Very long motor cables cause voltage drops due to the resistance of the cable. If the voltage drop is
significant, it could affect the current consumption and the torque available. This criterion must be taken into account when selecting
the motor and the starter.
Miscellaneous application precautions. Do not use the ATS48 controller upstream of loads other than motors (i.e., transformers and
resistance type loads)

Pricing and Special Feature Assistance
Schneider Electric personnel are to use the Q2C computer-based pricing system to determine Enclosed 48 controller
pricing. For pricing and delivery assistance on equipment and options not listed in Q2C or this pricing guide, contact the
Seneca Enclosed Drives Technical Applications Group (TAG) located in the Seneca plant for further assistance.

Enclosed 48 Catalog Number Identification
Class
8639

Type
48U

K

A

Modifications
4

N

C06, A07

Combination Device
8638 = Fusible Disconnect
8639 = Circuit Breaker

Factory Modifications (MODS)
C06 =Hand-Off-Auto selector switch
A07 =Run (Red) and Off (Green) lights

Soft Start Device
48U = Enclosed Altistart™ 48 Soft Start

Power Circuit Type
N=Non-reversing with isolation contactor
R=Reversing with isolation contactor
S=Shunt trip coil

Horsepower Rating
A = 3 hp
J = 40 hp
B = 5 hp
K = 50 hp
C = 7.5 hp L = 60 hp
D = 10 hp
M = 75 hp
E = 15 hp
N = 100 hp
F = 20 hp
P = 125 hp
G = 25 hp Q = 150 hp
H = 30 hp
R = 200 hp

Voltage Code (utilization)
2=208 V, 60 Hz
3=230 V, 60 Hz
4=460 V, 60 Hz
5=575 V, 60 Hz

S = 250 hp
T = 300 hp
U = 350 hp
W = 400 hp
X = 500 hp
Z = 600 hp

Enclosure Environment Rating
G=Type 1
A=Type 12
H=Type 3R

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP1G

Discount
Schedule

55

Pricing Guide

AC Soft Start Products
Enclosed Altistart 48 Soft Starts
Table 58:

Combination Controller—Enclosed 48 Soft Starts (Fusible Disconnect)
60Hz, Three-Phase, 208/230/460/575 Volts—AC3 Duty
8638 Power Circuit Type (Type 1 Enclosure)
(See page 58 for description)

Class 8638 Enclosed 48—FUSIBLE Disconnect

Size

A

B

C

D

E

Table 59:

Power Circuit
N
$ Price

Power Circuit
R
$ Price

Power Circuit
S
$ Price

15

2944.00

3327.00

2576.00

200.00

750.00

20

3128.00

3535.00

2668.00

200.00

750.00

25

3404.00

3847.00

2944.00

200.00

750.00

25

30

3662.00

4138.00

3128.00

200.00

750.00

15

30

40

3662.00

4138.00

3128.00

200.00

750.00

15

20

40

50

4180.00

4723.00

3608.00

300.00

1200.00

D75

20

25

50

60

5315.00

6006.00

4752.00

300.00

1200.00

D88

25

30

60

75

5940.00

6712.00

5368.00

300.00

1200.00

C11

30

40

75

100

6442.00

7279.00

5808.00

300.00

1200.00

C14

40

50

100

125

6800.00

7684.00

6205.00

450.00

1750.00

C17

50

60

125

150

7990.00

9029.00

7310.00

450.00

1750.00

C21

60

75

150

200

9070.00

10249.00

8415.00

600.00

2200.00

C25

75

100

200

250

10200.00

11526.00

9520.00

600.00

2200.00

C32

100

125

250

300

11645.00

13159.00

10600.00

600.00

2200.00

C41

125

150

300

350

11880.00

13424.00

10925.00

825.00

2900.00

C48

150

—

350

400

13864.00

15666.00

12240.00

825.00

2900.00

C59

—

200

400

500

15840.00

17899.00

13840.00

825.00

2900.00

C66

200

250

500

600

18920.00

21380.00

16480.00

825.00

2900.00

ATS48_YU

208 V

230 V

460 V

D17

3

5

10

D22

5

7.5

15

D32

7.5

10

20

D38

10

—

D47

—

D62

575 V

A

B

C

D

E

a

56

Type 12
$ Price

Type 3R
$ Price

Combination Controller—Enclosed 48 Soft Starts (Circuit Breaker Disconnect)
60Hz, Three-Phase, 208/230/460 Volts—AC3 Duty
8639 Power Circuit Type (Type 1 Enclosure)
(See page 58 for description)

Class 8639 Enclosed 48—CIRCUIT BREAKER Disconnect

Size

Enclosure Type
Adders

ATS48_YU

208 V

230 V

460 V

575 V

Power Circuit Power Circuit Power Circuit
N
R
S
$ Price
$ Price
$ Price

Enclosure Type
Adders
Type 12
$ Price

Type 3R
$ Price

D17

3

5

10

2856.00

3227.00

2499.00

200.00

750.00

D22

5

7.5

15

3034.00

3429.00

2588.00

200.00

750.00

D32

7.5

10

20

3302.00

3731.00

2856.00

200.00

750.00

D38

10

—

25

3552.00

4013.00

3034.00

200.00

750.00

D47

—

15

30

3552.00

4013.00

3034.00

200.00

750.00

D62

15

20

40

4055.00

4582.00

3500.00

300.00

1200.00

D75

20

25

50

5156.00

5826.00

4609.00

300.00

1200.00

D88

25

30

60

5762.00

6511.00

5207.00

300.00

1200.00

C11

30

40

75

6248.00

7061.00

5634.00

300.00

1200.00

C14

40

50

100

6596.00

7453.00

6019.00

450.00

1750.00

C17

50

60

125

7750.00

8758.00

7091.00

450.00

1750.00

C21

60

75

150

8797.00

9941.00

8163.00

600.00

2200.00

C25

75

100

200

9894.00

11180.00

9234.00

600.00

2200.00

C32

100

125

250

11296.00

12764.00

10282.00

600.00

2200.00

C41

125

150

300

11524.00

13022.00

10597.00

825.00

2900.00

C48

150

—

350

13448.00

15196.00

11873.00

825.00

2900.00

C59

—

200

400

15365.00

17362.00

13425.00

825.00

2900.00

C66

200

250

500

18352.00

20738.00

15986.00

825.00

2900.00

a

Not available in 575 V ratings.

CP1G

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Soft Start Products
Enclosed Altistart 48 Soft Starts

Configuration & Factory Modifications

Altistart™ 48 Soft Start Device Features

The Enclosed 48 combination controllers can be
configured with pre-engineered features and functions
identified below. Factory modifications (MODS) identified
by “custom engineered option” has extended lead times
and will be handled by a factory order engineer for
processing.

Enclosed 48 Features

•

Class 8638 fusible disconnect version with provisions for Class
J or L fuses are provided. Fuses are not installed at the factory.
Class 8639 circuit breaker version provided with MAG-GARD
or thermal-magnetic circuit breaker as OCPD.
Three power circuit configurations—shunt trip, non-reversing
and reversing options.
Industrial rated flange disconnect operating handle and
mechanism.
Shorting contactors (AC1 duty) provided on all Enclosed 48
soft starts.
Input isolation contactor option.
Full voltage bypass (AC3 duty) option.
Transient suppression modules on all contactors.
Agency listing to UL 508 Industrial Control Equipment. cUL
and/or CSA label available as an option.
Coordinated short circuit ratings:

•
•
•
•
•
•
•
•

Enclosure
Size

•

A–C

•
•
•
•
•
•
•
•
•
•

Horsepower Rating
@ 208 V

@ 230 V

@ 460 V

@ 575 V

8638
Fusible
Disconnect

8639
Circuit
Breaker

3–50

5–60

10–125

15–150

100k

25k

D

60–100

75–125

150–250

200–300

100k

30k

E

125–200

150–250

300–500

350–600

65k

30k

Type 1, 12 or 3R enclosure environmental ratings.
22 mm LED long life pilot light clusters with option for push-totest configurations.
120 Vac control power transformers, with or without an
additional 150 VA for customer use.
Top and bottom conduit knockouts on wall-mounted
enclosures
Removable conduit entry plates on floor mounted enclosures.
Cabinet component identification.
ANSI #49 gray enclosure paint.
Door mounted keypad on Type 1 and 12 units.
Wire marking identification.
Factory specific drawings.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP1G

Discount
Schedule

TCS™ Torque Control System
The Atlistart 48 soft start uses TCS ramping to accelerate
the motor to full voltage. Basing the acceleration ramp on
the motor torque rather than current or voltage, as used in
traditional soft starts, provides a linear speed ramp
independent of the motor loading without tachometer
feedback. The TCS ramp is also used for improved control
of deceleration independent of motor loading. When used
in pumping applications, TCS ramping can eliminate water
hammer problems and provide an alternative to expensive
motorized control values.

Starting and Stopping
Four types of starting are available:

•
•
•
•

TCS soft start—adjustable from 1 to 60 seconds
TCS with “boost”—adjustable 50 to 100% of mains voltage
Current limit—adjustable from 150 to 500% of controller rating
Voltage ramping

Modes of stopping

•
•

Freewheel or coast to stop
TCS soft stop—adjustable from 1 to 60 seconds

Device Protective Features

•
•
•
•
•
•
•
•

Solid State motor thermal overload protection—programmable
from Class 10 through 30
Soft start thermal protection
Motor phase loss protection
Line supply failure
Overcurrent fault
Locked rotor fault
Line frequency outside limits ±5% or ±20%—EGSA
compliance with Class 3 application (droop operation)
generators.
Selectable protection, including:
—
—
—
—
—

Phase reversal
Stall and jam
Thermal overload pre-alarm
Current threshold alarm
Underload fault

57

Pricing Guide

AC Soft Start Products
Enclosed Altistart 48 Soft Starts

Device Monitoring and Indication

Power Circuit Descriptions (pick one)

Door mounted keypad:

Power Circuit N—
Non-Reversing with Isolation Contactor

•
•
•

Displays setup parameters and fault codes.
Factory presets for most common adjustments.
Security to avoid accidental controller modifications is
provided by dipswitches on the back of the keypad, which
must be adjusted to provide access to three programming
levels.

Real time indication via the digital keypad of:

•
•
•
•
•

Motor current
Load Torque
Motor thermal state
Power factor
Fault status

Two logic outputs:

•
•
•

Motor thermal overload or indication of motor current present
Current threshold alarm
Motor underload alarm

One analog output for 4 to 20 or 0 to 20 mA indication of
motor current, torque, thermal state, active power or
power factor.
Two logic inputs, which are configurable for force to
freewheel, thermal overload reset or indication of external
fault.
Refer to the Altistart™ 48 product catalog (8636CT0201)
for additional information.

A contactor ahead of the soft start is coordinated to
automatically disconnect the motor from the ac line in the
conditions of a fault. In addition, the isolation contactor is
coordinated to open when the motor is not running. This
provides protection from voltage transients when the
electronics are most susceptible to damage. The isolation
contactor operation shall be coordinated via the R1 relay
in isolation contactor control mode. The control scheme
and contactor sequencing shall maintain the control power
and remove the main power to the soft start after a fault or
normal stop. Not available with shunt trip option, and is
required with full voltage bypass option.

Power Circuit R—
Reversing with Isolation Contactor
The reversing combination starter is configured for
forward and reverse operation through a reversing
contactor and appropriate logic control. The reversing
contactor also provides isolation for the motor from the
line supply power following a stop command (and
deceleration period, if selected) or in the condition of a
fault. Control of the forward and reverse contactors shall
use time delay relays (time set for 2 seconds) and the R1
fault relay in fault configuration. Not available with NEMA®
contactors or full voltage bypass.

Power Circuit S—
Shunt Trip Coil
If a fault is detected, a shunt trip coil on the disconnect
means removes all power on the load side of the
disconnect. The disconnect must be reset before
restarting is permitted after all fault conditions. The shunt
trip function shall be coordinated via a time delay relay
(time set for 2 seconds) signaled from the R1 relay in fault
configuration. Shunt trip coils shall be standard for MCC &
option S for enclosed, and available on both circuit
breaker & molded case switch versions. Not available with
input isolation contactor option (Power Circuit N).

58

CP1G

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Soft Start Products
Enclosed Altistart 48 Soft Starts

Control Options (pick one)
Mod
A06

Meter Display Options (pick one)

Start/Stop push buttons

$ Price

Provides black start and red stop push buttons
(3 wire control scheme).

132.00

Rules:Not available on Power Circuit R (Reversing).

Mod
B06

Forward-Off-Reverse selector switch

$ Price

Provides three-position selector switch to select between
forward, off and reverse. Uses 2-wire control.

240.00

Hand-Off-Auto selector switch

$ Price

Provides a three-position selector switch, 2-wire control
scheme.

132.00

Stop-Run selector switch

$ Price

Provides a two-position selector switch.

132.00

Rules:Not available on Power Circuit R (Reversing).

Mod
E06

Hand-Auto selector switch and Start/Stop push buttons $ Price
Provides a two-position selector switch and start/stop push
buttons (3-wire control).

264.00

Rules:Not available on Power Circuit R (Reversing).

Pilot Light Cluster Options (pick one)
Pilot light cluster #1
Mod
A07

$ Price

Consists of red “RUN” and green “OFF” pilot lights. Provides
standard red “RUN (ON)” and green “OFF” pilot lights for status 180.00
annunciation.

Pilot light cluster #2
Mod
B07

Mod
B08

Elapsed Time Meter

$ Price

Provides a seven-digit analog, non-resettable elapsed run time 348.00
meter.

Communications/Gateway Options
(pick one)
Factory installed communication features shall be available
as a custom engineered option utilizing the RJ45
communications port for control and annunciation of the
soft start in “link” mode.
Mod
A09

Modbus™

$ Price

Provides Modbus communications (native protocol)

850.00

Mod
B09

Modbus Plus

$ Price

Provides Modbus communications.

950.00

Mod
C09

Ethernet

$ Price

Provides Ethernet gateway communications protocol.

950.00

Mod
D09

DeviceNet™

$ Price

Provides DeviceNet gateway communications protocol.

950.00

$ Price

Consists of red “RUN” (push-to-test) and green “OFF” (push-totest) pilot lights. Provides push-to-test type red “RUN (ON)” and 360.00
standard green “OFF” pilot lights for status annunciation.
Pilot Light Cluster #3

Mod
C07

$ Price

Rules:Not available on Type 3R Enclosed.

Rules:Not available on Power Circuit R (Reversing).
Mod
D06

Ammeter

Provides a single-phase ammeter fed from the ATS48 analog 1188.00
output. Dial is in percent of device rated current.

Rules:Not available on Type 3R Enclosed.

Rules:Available for Power Circuit R (Reversing) configurations only.

Mod
C06

Mod
A08

$ Price

Consists of red “RUN”, green “OFF” and yellow “FAULT” pilot
lights. Provides standard red “RUN (ON)”, green “OFF”, and
yellow “FAULT” pilot lights for status annunciation.

270.

Rules: Not available with Power Circuit S (Shunt Trip).
Pilot light cluster #4
Mod
D07

$ Price

Consists of red “RUN (ON)” (push-to-test), green “OFF” (pushto-test) and yellow “FAULT” (push-to-reset) pilot lights. Provides
push-to-test type red “RUN (ON)”, standard green “OFF”, and 540.00
push-to-reset type yellow “FAULT” for status annunciation.

Rules:Not available on Power Circuit S (Shunt Trip).

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP1G

Discount
Schedule

59

Pricing Guide

AC Soft Start Products
Enclosed Altistart 48 Soft Starts

Miscellaneous Options (multiple compatible options may be selected)
Full voltage bypass

Mod
A10

$ Price

Provides an AC3 duty rated bypass/shorting contactor,
normal/bypass selector switch, Class 20 bi-metal motor OL
relay, door mounted OL reset push-button for across the line
starting capability.
Enclosure Size A adder:
Enclosure Size B adder:
Enclosure Size C adder:
Enclosure Size D adder:
Enclosure Size E adder:

Mod
M10
500.00
600.00
700.00
750.00
900.00

Rules:Only available for Power Circuit N (Non-Reversing). Not available with
Power Circuit S (Shunt Trip) SCR fault isolation scheme.

Mod
B10

150 VA additional control power capacity

$ Price

Provides 150 VA additional control VA capacity for customer 150.00
use.

Power Up ON delay (start relay)
Mod
C10

Mod
P10

Mod
Q10

Mod
R10

Mod
F10

1400.00

$ Price

Provides the option to configure the enclosure paint scheme to 375.00
standard ANSI #61 paint instead of ANSI #49 paint.

MOV / Surge arrestor (custom engineered option)

$ Price

Provides supplementary MOV protection using a
Class 6671 SDSA3650 Surgebreaker™ secondary surge
arrester hard-wired and factory mounted.

450.00

$ Price

Dual motor overloads and branch circuit protection
(custom engineered option)

“cUL” Label

$ Price

Provides a Canadian Underwriters Laboratories label when
required by local code requirements.

200.00

Provides dual-rated motor OLs rated equally, one-half
the hp of the selected starter. Motor branch short circuit
protection is provided per NEC™. Maximum total current
rating of the combined motors not to exceed the continuous
current rating of the starter package.

Auxiliary contacts for run mode

$ Price

Provides 1 Form 'C' contact rated 5 A @ 120 Vac
(8501 Type R relay or equivalent) wired to terminal blocks for
customer use. Contacts change state when soft start is
550.00
sending current to the motor. Controlled by the R3 relay
programmed for “rnl”.

Mod
S10

Enclosure Size A adder:
Enclosure Size B adder:
Enclosure Size C adder:
Enclosure Size D adder:
Enclosure Size E adder:

Omit door mounted keypad display
Mod
U10

Auxiliary contacts for fault mode

Rules: Only for Type 3R size D and E enclosures.
NEMA® style contactors (custom engineered option)

Mod
W10

Motor space heater provisions
(custom engineered option)

$ Price

$ Price

Provides horsepower rated NEMA rated contactors instead
of AC3 rated IEC TeSys™ or F-line contactors.
Enclosure Size A adder: 400.00
Enclosure Size B adder: 600.00
Enclosure Size C adder: 700.00
Enclosure Size D adder: 2000.00
Enclosure Size E adder: 4500.00

Rules:Not available with Power Circuit R (Reversing) or MOD A10 (Full voltage
bypass.
50 Degrees C operation
Mod
X10

$ Price

Provides an auxiliary starter mode (auto) contact that
will energize a relay with 1 Form 'C' contact rated 5 A @ 120
Vac (8501 Type R relay or equivalent) wired to terminal blocks 650.00
for customer use.

$ Price

Removes the keypad display from outside the enclosure door.
The keypad on the ATS48 soft start can be used for
(50.00)
programming and commissioning.

$ Price

Provides an auxiliary starter mode (auto) contact that
will energize a relay with 1 Form 'C' contact rated 5 A @ 120
Vac (8501 Type R relay or equivalent) wired to terminal blocks 550.00
for customer use.

820.00
1874.00
2645.00
3160.00
6570.00

Rules:Available on Class 8639 circuit breaker disconnect configurations only.

$ Price

Provides 1 Form 'C' contact rated 5 A @ 120 Vac
(8501 Type R relay or equivalent) wired to terminal blocks for 550.00
customer use. Contacts change state when motor is operated
across the line with full voltage bypass starter.

Rules:MOD C06 (Hand-Off-Auto selector switch) or E06 (Hand-Auto selector
switch) must be specified.

Mod
K10

ANSI #61 painted enclosure
(custom engineered option)

$ Price

Auxiliary contacts for auto mode

Mod
J10

$ Price

Provides permanent sleeve type wire markers on control
wiring assemblies.

140.00

Rules:MOD A10 (Full Voltage Bypass) must be selected. Must use Power Circuit
N or R (line isolation contactor combination). Not compatible with Power
Circuit S (Shunt Trip).

Mod
H10

Permanent wire markers

Provides a push-button for immediate removal of all power.

Auxiliary contacts for full voltage bypass run mode
Mod
G10

340.00

Emergency Stop push button

Rules:Requires Power Circuit S (Shunt Trip).

Mod
E10

$ Price

Provides up to (10) spare terminal blocks 'unwired' for
customer use. Since Phoenix style terminal blocks will be
used, extra terminal points will be provided as standard.
20 terminal points are available as standard for all control
wiring (including any additional customer spare terminal
points).

$ Price

Provides an electronic time delay relay adjustable from 0.1 to
60 seconds. Relay is pre-wired to inhibit start for users set
150.00
delay time upon power-up of control power circuit.

Rules:Only available on 2-wire control circuits.
Mod
D10

Spare terminal blocks

$ Price

Provides extended range high ambient equipment rating
above 40 °C (104 °F) to a maximum of 50 °C (122 °F) without 125.00
de-rating.

Rules:Standard on Type 3R enclosures.
Seismic Qualification label
Mod
Y10

Provides control circuit contacts, 120 V, 150–500 kW supply 640.00
and fusing, wired to terminals (9080 GM6) for customer use.

$ Price

Provides a self-certified identification label with compliance to
2000 IBC, NFPA™ 5000, 2001 CBC, 1997 UBC, 1999 NBC,
1999SBC, ASCE-7 02 seismic qualification/certification. The 450.00
label criteria will be uniform for all enclosed products.
Enclosures shall contain additional bracing as defined by the
seismic qualification/certification criteria.

Rules:Not available for Enclosure Sizes A–C (wall mounted enclosures).
Mod
L10

ID engraved nameplates

$ Price

Provides a lamacoid nameplate, engraved with equipment
designation.

50.00

Mod
Z10

Mod
610

60

CP1G

Discount
Schedule

Service Entrance Rating

$ Price

Provides a UL869A approved insulated ground neutral lug
assembly, mounting bracket with bonded enclosure ground
wire suitable for use as service entrance equipment.

185.00

100 k Circuit Breaker Rating

$ Price

Only available:
208 V, 125–200 hp
230 V, 150–250 hp
460 V, 300–500 hp

2000.00

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Soft Start Products
Enclosed Altistart 48 Soft Starts — Class 8636, 8638, and 8639

Table 60:

Renewal Parts
Class 8636 Controllers

Description

Line
Voltage

Standard
Duty

Heavy
Duty

460 V

10–20 hp a

10–20 hp

7.5–15 hp

208 V

3–7.5 hp a

3–7.5 hp

2–5 hp

230 V
460 V

Control Power
Primary Fuse
FU8
Standard VA

30–60 hp

2543020020

11.00

2543020050

11.00

15–40 hp

15–40 hp

10–30 hp

100–125 hp

100–125 hp

75–100 hp

2543020100

11.00

208 V

10–25 hp

10–30 hp

10–30 hp

7.5–25 hp

2543020112

11.00

460 V

125 hp

150 hp

150 hp

125 hp

2543020125

14.76

460 V

250–400 hp

300–500 hp

300–500 hp

150–400 hp

2543020150

11.00

460 V

150–200 hp

200–250 hp

200–250 hp

150–200 hp

150 hp

2543020180

11.00

230 V

40–50 hp

50–60 hp

50– 60 hp

40–50 hp

40 hp

2543020200

11.00

208 V

30–40 hp

40–50 hp

40–50 hp

30–40 hp

30 hp

230 V

60 hp

75 hp

75 hp

60 hp

2543020250

13.68

2543020300

11.00

2543020350

11.00

75 hp

125 hp

208 V

50 hp

60 hp

60 hp

50 hp

230 V

125–200 hp

150–250 hp

150–250 hp

125– 200 hp

208 V

100–150 hp

125–200 hp

125–200 hp

100–150 hp

230 V

75–100 hp

100–125 hp

100–125 hp

75–100 hp

75 hp

60 hp

208 V

60–75 hp

60 hp

50 hp

30–60 hp
75–100 hp

208 V

75–100 hp

75–100 hp

60–75 hp

2543020400

11.00

10–20 hp a

10–20 hp

7.5–15 hp

2543020060

11.00

30–75 hp

30–75 hp

20–60 hp

2543020100

11.00

5–10 hp a

5–10 hp

3–7.5 hp

100–125 hp

100–125 hp

75–100 hp

2543020150

11.00

3–7.5 hp a

3 –7.5 hp

2 –5 hp

2543020160

14.76

75 hp

460 V

125 hp

150 hp

150 hp

125 hp

2543020180

11.00

230 V

15–30 hp

15–40 hp

15–40 hp

10–30 hp

2543020200

11.00

208 V

10–25 hp

10–30 hp

10 –30 hp

7.5–25 hp

460 V

150–400 hp

200–500 hp

200–500 hp

150–400 hp

150 hp

2543020250

13.68

2543020300

11.00

2543020320

11.00

2543020350

11.00

230 V

40–50 hp

50–60 hp

50–60 hp

40–50 hp

40 hp

230 V

75–200 hp

100–250 hp

100–250 hp

75–200 hp

75 hp

208 V

30–40 hp

40–50 hp

40–50 hp

30– 40 hp

30 hp

230 V

60 hp

75 hp

75 hp

60 hp

208 V

50–150 hp

460 V
460 V

30–60 hp

230 V

a

20–60 hp

$ Price

15–30 hp

460 V

Form T42
200 Additional VA

3–7.5 hp

30–75 hp

Catalog Number

75–100 hp

230 V

Control Power
Primary Fuse
FU8

5–10 hp

30–75 hp

Heavy
W/Bypass

460 V

460 V

Form T41
100 Additional VA

5–10 hp a

Standard
W/Bypass

230 V

460 V

Control Power
Primary Fuse
FU8

Class 8638/8639 Combination Controllers

Type
1 and 12
W/Shorting

Type 1
No Shorting

60–200 hp

60–200 hp

50–150 hp

2543020400

11.00

10–20 hp

7.5–15 hp

2543020125

14.67

30–75 hp

30–75 hp

20–60 hp

2543020150

11.00

5–10 hp a

5–10 hp

3–7.5 hp
2543020250

13.68

2543020300

11.00

2543020320

11.00

2543020350

11.00

2543020400

11.00

75–125 hp

100–150 hp

100–150 hp

75–125 hp

460 V

250–400 hp

300–500 hp

300–500 hp

250–400 hp

208 V
230 V

15–30 hp

60 hp

10–20 hp a

460 V

3–7.5 hp a

3–7.5 hp

2–5 hp

15–40 hp

15–40 hp

10–30 hp

230 V

40–60 hp

50–75 hp

50–75 hp

40–60 hp

230 V

125–200 hp

150–250 hp

150–250 hp

125–200 hp

60 hp

125 hp

50 hp

75 hp

40 hp

208 V

10–25 hp

10–30 hp

10–30 hp

7.5–25 hp

460 V

150–200 hp

200–250 hp

200–250 hp

150–200 hp

150 hp
30 hp

125 hp

208 V

30–50 hp

40–60 hp

40– 60 hp

30–50 hp

208 V

100–150 hp

125–200 hp

125–200 hp

100–150 hp

230 V

75–100 hp

100–125 hp

100–125 hp

75–100 hp

75 hp

60 hp

2543020500

11.00

208 V

60–75 hp

75–100 hp

75–100 hp

60–75 hp

60 hp

50 hp

2543020600

11.00

These Type 1 and 12 units are not shipped with a shorting contactor installed.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

PE4

Discount
Schedule

61

Pricing Guide

AC Soft Start Products
Enclosed Altistart 48 Soft Starts — Class 8636, 8638, and 8639

Table 61:

Renewal Parts
Class 8636 Controllers

Description

Control Power
Secondary Fuse
FU6 & 7
Standard VA

Control Power
Secondary Fuse
FU6 & 7
Form T41
100 Additional VA

Control Power
Secondary Fuse
FU6 & 7
Form T42
200 Additional VA

a
b

62

Line
Voltage

Class 8638/8639 Combination Controllers

Type
1 & 12
W/Shorting

Standard
Duty

208 V

3–7.5 hp a

3–7.5 hp

2–5 hp

230 V

5–10 hp a

5–10 hp

3–7.5 hp

460 V

10–20 hpa

10–20 hp

7.5 –15 hp
7.5–25 hp

Type 1
No Shorting

Heavy
Duty

Standard
W/Bypass

208 V

10–25 hp

10–30 hp

10–30 hp

230 V

15–30 hp

15– 40 hp

15–40 hp

10–30 hp

460 V

30–60 hp

30–75 hp

30–75 hp

20–60 hp

208 V

30–40 hp

40–50 hp

40–50 hp

30–40 hp

30 hp

230 V

40–50 hp

50–60 hp

50–60 hp

40–50 hp

40 hp

460 V

75–100 hp

100–125 hp

100–125 hp

75–100 hp

75 hp

208 V

50 hp

60 hp

60 hp

50 hp

230 V

60 hp

75 hp

75 hp

60 hp

460 V

125 hp

150 hp

150 hp

125 hp

208 V

100–150 hp

125–200 hp

125–200 hp

100–150 hp

230 V

125–200 hp

150–250 hp

150–250 hp

125–200 hp

460 V

250–400 hp

300–500 hp

300–500 hp

250–400 hp

Heavy
W/Bypass

208 V

60–75 hp

75–100 hp

75–100 hp

60–75 hp

60 hp

230 V

75–100 hp

100–125 hp

100–125 hp

75–100 hp

75 hp

60 hp

460 V

150–200 hp

200–250 hp

200–250 hp

150–200 hp

150 hp

125 hp

208 V

3–7.5 hp a

3–7.5 hp

2–5 hp

230 V

5–10 hp a

5–10 hp

3–7.5 hp

460 V

10–20 hp a

10–20 hp

7.5–15 hp
7.5–25 hp

10–25 hp

10–30 hp

10–30 hp

230 V

15–30 hp

15– 40 hp

15–40 hp

10–30 hp

460 V

30–60 hp

30–75 hp

30–75 hp

20–60 hp

208 V

30–40 hp

40–50 hp

40–50 hp

30–40 hp

30 hp

230 V

40–50 hp

50–60 hp

50–60 hp

40–50 hp

40 hp

460 V

75–100 hp

100–125 hp

100–125 hp

75–100 hp

75 hp

208 V

50 hp

60 hp

60 hp

50 hp

230 V

60 hp

75 hp

75 hp

60 hp

460 V

125 hp

150 hp

150 hp

125 hp

208 V

60–150 hp

75–200 hp

75–200 hp

60–150 hp

60 hp

230 V

75–200 hp

100–250 hp

100–250 hp

75–200 hp

75 hp

60 hp

460 V

150–400 hp

200–500 hp

200–500 hp

150–400 hp

150 hp

125 hp

208 V

3–7.5 hp a

3–7.5 hp

2–5 hp

230 V

5–10 hp a

5–10 hp

3–7.5 hp

460 V

10–20 hp a

10–20 hp

7.5–15 hp

10–25 hp

10–30 hp

10–30 hp

7.5–25 hp

230 V

15–30 hp

15–40 hp

15–40 hp

10–30 hp

460 V

30–60 hp

30–75 hp

30–75 hp

20–60 hp

208 V

30–50 hp

40–60 hp

40–60 hp

30–50 hp

208 V

100–150 hp

125–200 hp

125–200 hp

100–150 hp

230 V

40–60 hp

50–75 hp

50–75 hp

40–60 hp

230 V

125–200 hp

150–250 hp

150–250 hp

125–200 hp

460 V

75–125 hp

100–150 hp

100–150 hp

75–125 hp

460 V

250–400 hp

300–500 hp

300–500 hp

250–400 hp

$ Price

2543020060

11.00

2543020125b

14.76

2543020250b

13.68

2543020300

11.00

2543020400

11.00

2543020500

11.00

2543020200

11.00

2543020250b

13.68

2543020400

11.00

2543020500

11.00

2543020700

11.00

2543020300

11.00

2543020400

11.00

2543020700

11.00

2543021000

11.00

50 hp

208 V

208 V

Catalog Number

50 hp

30 hp
40 hp
75 hp

208 V

60–75 hp

75–100 hp

75–100 hp

60–75 hp

60 hp

230 V

75–100 hp

100–125 hp

100–125 hp

75–100 hp

75 hp

50 hp
60 hp

460 V

150–200 hp

200–250 hp

200–250 hp

150–200 hp

150 hp

125 hp

These Type 1 & 12 units are not shipped with a shorting contactor installed.
Discount Schedule for this product is PE4.

CP4C

PE4b

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Soft Start Products
Enclosed Altistart 48 Soft Starts — Class 8636, 8638, and 8639
Class 8636 Controllers

Description

Altistart™
CL1-CL2
Control Power Fuse
FU4 & 5

Auxiliary CPT
Primary Fuses
FU9 & 10

1.2 VA / 6 V Bulb
for Pilot Lights
a
b

Line
Voltage

Type 1
No Shorting

8638/8639 Combination Controllers

Type 1 & 12
W/Shorting

Standard
Duty

Heavy
Duty
2–7.5 hp

208 V

3–7.5 hp

3–10 hp a

3–10 hp

230 V

5–10 hp

5–15 hp a

5–15 hp

3–10 hp

460 V

10–75 hp

10–100 hp a

10–100 hp

7.5–75 hp

208 V

10–30 hp

15–40 hp

15–40 hp

10–30 hp

230 V

15–40 hp

20–50 hp

20–50 hp

15–40 hp

460 V

100–200 hp

125–250 hp

125–250 hp

460 V

250–400 hp

300–500 hp

300–500 hp

208 V

40–75 hp

50–100 hp

50–100 hp

40–75 hp

230 V

50–100 hp

60–125 hp

60–125 hp

50–100 hp

208 V

100–150 hp

125–200 hp

125–200 hp

100–150 hp

230 V

125–200 hp

150–250 hp

150–250 hp

125–200 hp

208 V

10–150 hp

10–200 hp

10–200 hp

7.5–150 hp

230 V

15–200 hp

15–250 hp

15–250 hp

10–200 hp

460 V

30–400 hp

30–500 hp

30–500 hp

20–500 hp

208 V

ALL

ALL

ALL

ALL

230 V

ALL

ALL

ALL

ALL

460 V

ALL

ALL

ALL

ALL

Catalog Number

$ Price

2543020025

11.00

2543020050

11.00

100–200 hp

2543020080

11.00

250–400 hp

2543020100

11.00

2543020160b

14.76

2543020200

11.00

2543021500

11.00

DL1CB006b

5.30

Units with the following hp ratings are not shipped with shorting contactors: 3–7.5 hp (208 V), 5–10 hp (230 V) and 10–20 hp (460 V)
Discount Schedule for this product is PE4.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

PE4b

Discount
Schedule

63

Pricing Guide

Line Reactors and Motor Protection Output Filters
Options

Options—Field Installed
Table 62:

Line Reactors—480 V Rated Three-Phase
460 V Drive Rating

Approx.
Wt.
(Lbs.)

Enclosure
Dimensions
HxWxD (In.)

169.00
174.00
262.00
308.00
357.00

RL00212a
RL00413a
RL00813a
RL01213
RL01813

11
12
18
25
49

8x8x6
8x8x6
15x13x13
15x13x13
15x13x13

310.00
315.00
405.00
455.00
590.00

RL02503
RL03503
RL04503
RL05503
RL08003

368.00
487.00
571.00
578.00
939.00

RL02513
RL03513
RL04513
RL05513
RL08013

49
61
70
72
86

15x13x13
15x13x13
15x13x13
15x13x13
15x13x13

602.00
727.00
816.00
822.00
1200.00

—
—
—
—
—

RL10003
RL13003
RL16003
RL20003
RL25003

1096.00
1120.00
1260.00
1539.00
2727.00

RL10013
RL13013
RL16013
RL20013
RL25013

105
105
105
131
185

15x13x13
15x13x13
15x13x13
15x13x13
24x17x17

1366.00
1392.00
1539.00
1831.00
3447.00

—
—
—
—

RL32003
RL40003
RL50003
RL60003

2915.00
3576.00
4150.00
5740.00

RL32013
RL40013
RL50013
RL60013

235
245
335
335

24x17x17
24x17x17
24x17x17
24x17x17

3646.00
4338.00
5761.00
7431.00

Enclosed
Part Number
(Type 1)

Approx.
Wt.
(Lbs.)

Enclosure
Dimensions
HxWxD (In.)

$ Price

Open Style
Part Number

1
2–3
5
7.5
10

—
—
—
—
—

RL00202a
RL00403a
RL00803a
RL01203
RL01803

15
20–25
30
40
50–60

—
—
—
—
—

75
100
125
150
200
250
300
350–400
450–500

Table 63:

$ Price

$ Price

Line Reactors—208/230 V Rated Three-Phase

208 V Drive Rating

230 V Drive Rating

Horsepower

kW

Horsepower

kW

Open Style
Part Number

1
1.5–2
3
5

—
—
—
—

1
1.5–2
3
5

—
—
—
—

RL00402
RL00802a
RL01202a
RL01802a

168.00
192.00
214.00
270.00

RL00412
RL00812a
RL01212a
RL01812a

11
15
17
19

8x8x6
8x8x6
8x8x6
8x8x6

308.00
332.00
356.00
416.00

7.5
10
15
20

—
—
—
—

7.5
10
15
20

—
—
—
—

RL02502a
RL03502
RL04502
RL05502

311.00
327.00
431.00
455.00

RL02512a
RL03512
RL04512
RL05512

45
47
59
59

15x13x13
15x13x13
15x13x13
15x13x13

542.00
559.00
669.00
693.00

25
30
40
50

—
—
—
—

25–30
40
50
—

—
—
—
—

RL08002
RL10002
RL13002
RL16002

534.00
746.00
848.00
1048.00

RL08012
RL10012
RL13012
RL16012

82
82
88
88

15x13x13
15x13x13
15x13x13
15x13x13

776.00
999.00
1106.00
1317.00

Enclosed
Part Number
(Type 1)

Approx.
Wt.
(Lbs.)

Enclosure
Dimensions
HxWxD (In.)

$ Price

Table 64:

a

Enclosed
Part Number
(Type 1)

kW

Horsepower

$ Price

Line Reactors—208/230 V Rated Single-Phase

208 V Drive Rating

230 V Drive Rating

Horsepower

kW

Horsepower

kW

Open Style
Part Number

.5
1
2
3

—
—
—
—

.5–1
2
3
—

—
—
—
—

RL00801
RL01201
RL01801
RL02501

171.00
202.00
263.00
275.00

RL00811
RL01211
RL01811
RL02511

15
17
19
45

8x8x6
8x8x6
8x8x6
15x13x13

311.00
344.00
407.00
504.00

—
5
7.5

3
—
—

—
5
7.5

3
—
—

RL01801
RL03501
RL04501

246.00
311.00
410.00

RL01811
RL03511
RL04511

47
59
82

15x13x13
15x13x13
15x13x13

380.00
542.00
646.00

$ Price

Suitable for use with ATV 312 drives, 575 V. See Altivar™ 31 Options for selection.

Table 65:

Motor Protecting Output Filters—480 V Rated Type 1 Enclosed Motor Protection Output Filters
(UL 508A)

Horsepower

Enclosure Dimensions
Amperes

Drive 460 V Rating

KLCUL Filter Enclosed
Part Number

$ Price

Approximate
Weight (lbs)

H

W

D

IN

mm

IN

mm

IN

mm

1–2
3
5
7.5
10

4
6
8
12
16

KLCUL4A1
KLCUL6A1
KLCUL8A1
KLCUL12A1
KLCUL16A1

1126.00
1148.00
1171.00
1224.00
1249.00

15
15
15
15
17

12.25
12.25
12.25
12.25
12.25

311
311
311
311
311

12.50
12.50
12.50
12.50
12.50

318
318
318
318
318

6.75
6.75
6.75
6.75
6.75

171
171
171
171
171

15
20–25
30
40
50–60

25
35
45
55
80

KLCUL25A1
KLCUL35A1
KLCUL45A1
KLCUL55A1
KLCUL80A2

1355.00
1485.00
1535.00
1672.00
2178.00

20
20
20
20
56

12.25
12.25
12.25
12.25
19.13

311
311
311
311
486

12.50
12.50
12.50
12.50
15.50

318
318
318
318
394

6.75
6.75
6.75
6.75
15.50

171
171
171
171
394

75
100
125
150
200

110
130
160
200
250

KLCUL110A2
KLCUL130A2
KLCUL160A2
KLCUL200A3
KLCUL250A3

3005.00
3368.00
3617.00
3766.00
3841.00

60
66
80
102
110

19.13
19.13
19.13
22.13
22.13

486
486
486
562
562

15.50
15.50
15.50
20.50
20.50

394
394
394
521
521

15.50
15.50
15.50
24.37
24.37

394
394
394
619
619

250
300
350
400
450–500

300
360
420
480
600

KLCUL300A3
KLCUL360A3
KLCUL420A3
KLCUL480A3
KLCUL600A3

3863.00
4300.00
4659.00
5221.00
5393.00

115
125
145
150
167

22.13
22.13
22.13
22.13
22.13

562
562
562
562
562

20.50
20.50
20.50
20.50
20.50

521
521
521
521
521

24.37
24.37
24.37
24.37
24.37

619
619
619
619
619

NOTE: Line reactors and filters are intended for separate mounting and wiring by the user.
Based on NEC™ (NFPA™ 70) 430–150 current ratings. If drive has higher FLA rating, use the
“amperes” rating to select the appropriate filter.

64

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61/71 Spare Parts Kits and Required Documentation

Table 66:

Kit Contents and Required Documentation

1—Identify Your Spare Parts Kit:
Kit Catalog Number
VX4A1103

Qty

Kit Contents

Frame Size

Catalog Number

3—$ Price

Control front cover with 4x7 Segments

1

Front cover assembly

All ATV61/ATV71

All ATV61/ATV71

144.00

VX4A1104

Control terminal board kit

1
2
1
1

Terminal PCBA
Insulated jumpers
Terminal PCBA lower cap
Terminal PCBA upper cap

All ATV61/ATV71

All ATV61/ATV71

142.00

VX4A1106

Filter board

1

Filter board

6

ATV61HD18M3X
ATV61HD22M3X
ATV71HD18M3X
ATV71HD22M3X

46.00

VX4A1107

Filter board

1

Filter board

6

ATV61HD22N4
ATV71HD22N4

260.00

VX4A1108

Filter board

1

Filter board

7A

ATV61HD30N4
ATV61HD37N4
ATV71HD30N4
ATV71HD37N4

149.00

VX4A1109

Filter board

1

Filter board

7B

ATV61HD30M3X
ATV61HD37M3X
ATV61HD45M3X
ATV71HD30M3X
ATV71HD37M3X
ATV71HD45M3X

84. 00

VX4A1110

Filter board

1

Filter board

8

ATV61HD45N4
ATV61HD55N4
ATV61HD75N4
ATV71HD45N4
ATV71HD55N4
ATV71HD75N4

130.00

VX4A1113

Filter board

1

Filter board

11

ATV61HC16N4
ATV71HC13N4

294.00

VX4A1114

Filter board

1

Filter board

12

ATV71HC16N4
ATV61HC22N4

382.00

VX4A1115

Filter board

1

Filter board

13

ATV61HC25N4
ATV61HC31N4
ATV71HC20N4
ATV71HC25N4
ATV71HC28N4

412.00

151.00

VX4A1116

VX4A1117

VX4A1118

VX4A1200

a

2—Identify Your Drive:
Description

1

Filter board

9

ATV61HD75M3X
ATV61HD90N4
ATV61HD55M3X
ATV61HC11N4
ATV71HD90N4
ATV71HD55M3X

1

Filter board

10

ATV61HC13N4
ATV61HD90M3X
ATV71HC11N4
ATV71HD75M3X

244.00

14B
Filter board

ATV61HC50N4
ATV71HC40N4

333.00

1

15

ATV61HC63N4
ATV71HC50N4

294.00

14A

ATV61HC40N4
ATV71HC31N4

144.00

11

ATV61HC16N4
ATV71HC13N4

142.00

12

ATV71HC16N4
ATV61HC22N4

46.00

13

ATV61HC25N4
ATV61HC31N4
ATV71HC20N4
ATV71HC25N4
ATV71HC28N4

260.00

14A

ATV61HC40N4
ATV71HC31N4

149.00

14B

ATV61HC50N4
ATV71HC40N4

84. 00

15

ATV61HC63N4
ATV71HC50N4

130.00

Filter board

Filter board

Filter board

SCRa Snubber Board

1

1

Filter board

SCR snubber board

SCR: Silicon controlled rectifier.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

65

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61/71 Spare Parts Kits and Required Documentation

Kit Contents and Required Documentation (Continued)
1—Identify Your Spare Parts Kit:
Kit Catalog Number

2—Identify Your Drive:
Description

Qty
1

1
9

Spring, 5 mm x 14 mm
Screws, M3 x 8, thread
forming
Motor control PCBA
Interface PCBA
Application/interface PCBA
cable
Application PCBA insulate
sheet
Flat washer, M4
Screw, captive washer,
M4 x 20
Control ground bar
Terminal PCBA lower cap
Control support
Display support
Control trap
Terminal PCBA upper cap
Keyboard
Application PCBA
Display PCBA
Terminal PCBA
Application PCBA / motor
control
Spacing assembly
Control trap label kit
Option LED label
Brand marking label
Relay label
AI label
LI label
Control switch label
Modbus label

ATV61HD75M3X HD90N4,
HD55M3X HC11N4,
HC13N4 HD90M3X
HC16N4
HC22N4, HC25N4 HC31N4,
9, 10, 11, 12, 13, 14, 15
HC40N4
HC50N4, HC63N4
HC11Y, HC13Y HC16Y,
HC20Y HC25Y, HC31Y
HC40Y, HC50Y HC63Y
HC80Y

375.00

Screw, captive washer,
M4 x 8
Screw, captive washer,
M4 x 10
Screws with washers,
M3 x 8
Spring, 5 mm x 14 mm
Screws, M3 x 8, thread
forming
Application PCBA insulate
sheet
Flat washer, M4
Screw, M4 x 20
Control ground bar
Terminal PCBA lower cap
Control support
Display support
Terminal PCBA upper cap
Keyboard
Application PCBA
Motor control PCBA
Display PCBA
Terminal PCBA
Application PCBA / motor
control
Option LED label
Brand marking label
Relay label
AI label
LI label
Control switch label
Modbus label
Motor control insulate sheet

ATV71H037M3, H075M3,
H075N4 HU15M3, HU15N4
HU22N4, HU22M3 HU30M3,
HU30N4 HU40M3, HU40N4
HU55M3, HU55N4 HU75N4,
HD11N4 HU75M3,
HD11M3X HD15M3X
HD15N4 HD18N4,
HD18M3X HD22M3X,
HD22N4
HU22Y, HU30Y
HU40Y, HU55Y
HU75Y, HD11Y
HD15Y, HD18Y
HD22Y, HD30Y HD30N4,
HD37N4 HD30M3X
HD37M3X
HD45M3X HD45N4
HD55N4, HD75N4
HD37Y, HD45Y
HD55Y, HD75Y
HD90Y

325.00

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
9
1

VX4A71100Y

ATV71 control board kit, <90 kW

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

66

325.00

Option LED label
Brand marking label
Relay label
AI label
LI label
Control switch label
Modbus™ label
Motor control insulate sheet

1

ATV61 Control board kit, ≥ 90 kW

2, 3, 4, 5A, 5B, 6, 7A,
7B, 8

ATV61H075M3 H075N4,
HU15N4
HU22N4, HU22M3 HU15M3,
HU30M3 HU30N4, HU40M3
HU40N4, HU55M3 HU55N4,
HU75N4 HD11N4, HU75M3
HD11M3X, HD15M3X,
HD15N4
HD18N4, HD18M3X
HD22M3X, HD22N4
HU30Y, HU40Y
HU55Y, HU75Y
HD11Y, HD15Y
HD18Y, HD22Y
HD30Y, HD30N4
HD37N4, HD30M3X
HD37M3X
HD45M3X,HD45N4
HD55N4, HD75N4 HD37Y,
HD45Y HD55Y, HD75Y
HD90Y,

1
1
1
1
1
1
1
1

1
9

VX4A61101Y

Catalog Number

1
1
1
1
1
1
1
1
1
1
1
1
1

4

ATV61 Control board kit, <90 kW

3—$ Price

Frame Size

Screw, captive washer,
M4 x 8
Screw, captive washer,
M4 x 10
Screws with washers,
M3 x 8
Spring, 5 mm x 14 mm
Screws, M3 x 8, thread
forming
Application PCBA insulate
sheet
Flat washer, M4
Screw, M4 x 20
Control ground bar
Terminal PCBA lower cap
Control support
Display support
Terminal PCBA upper cap
Keyboard
Application PCBA
Motor control PCBA
Display PCBA
Terminal PCBA
Application PCBA / motor control

1

VX4A61100Y

Kit Contents

CP4C

Discount
Schedule

2, 3, 4, 5A, 5B, 6, 7A,
7B, 8

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61/71 Spare Parts Kits and Required Documentation

Kit Contents and Required Documentation (Continued)
1—Identify Your Spare Parts Kit:
Kit Catalog Number

2—Identify Your Drive:
Description

Qty
1
9

1
1
1
1
1
1
1
1
1

Spring, 5 mm x 14 mm
Screws, M3 x 8, thread
forming
Motor control PCBA
Interface PCBA
Application/interface PCBA
cable
Application PCBA insulate
sheet
Flat washer, M4
Screw, captive washer,
M4 x 20
Control ground bar
Terminal PCBA lower cap
Control support
Display support
Control trap
Terminal PCBA upper cap
Keyboard
Application PCBA
Display PCBA
Terminal PCBA
Application PCBA / motor
control
Spacing assembly
Control trap label kit
Option LED label
Brand marking label
Relay Label
AI label
LI label
Control switch label
Modbus™ label

1
6

Gate driver PCBA
Plastic supports

1
2

1
1
1
1
1
1

VX4A71101Y

VX5A1200

VX5A1201

ATV71 control board kit, >=90 kW

Gate driver board

Gate driver board

VX5A1202

Gate driver board

VX5A1203

Gate driver board

VX5A1204

Gate driver board

1
1
1
1
1
1
1
1
1
1
1

Soft charge board

Fan control board

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

ATV71HC11N4, HD75M3X,
HD55M3X, HD90N4
HC13N4, HC16N4 HC11Y,
HC13Y HC16Y, HC20Y
9, 10, 11, 12, 13, 14, 15
HC20N4, HC28N4
HC25N4, HC25Y HC31Y,
HC40Y HC50N4, HC31N4
HC40N4, HC50Y HC63Y

Gate driver PCBA
Cable clamps

12

ATV71HC16N4
ATV61HC22N4

1
2

Gate driver PCBA
Cable clamps

13

ATV61HC25N4
ATV71HC20N4

1
2

Gate driver PCBA
Cable clamps

13

ATV61HC31N4
ATV71HC25N4
ATV71HC28N4

1
7

Gate driver PCBA
Cable clamps

14A

ATV61HC40N4
ATV71HC31N4

1
7

Gate driver PCBA
Cable clamps

14B

ATV61HC50N4
ATV71HC40N4

1
8

Gate driver PCBA
Cable clamps

15

ATV61HC63N4
ATV71HC50N4

9

ATV61HD75M3X
ATV61HD90N4
ATV61HD55M3X
ATV61HC11N4
ATV71HD90N4
ATV71HD55M3X

10

ATV61HC13N4
ATV61HD90M3X
ATV71HC11N4
ATV71HD75M3X

11

ATV61HC16N4
ATV71HC13N4

12

ATV71HC16N4
ATV61HC22N4

13

ATV61HC25N4
ATV61HC31N4
ATV71HC20N4
ATV71HC25N4
ATV71HC28N4

14A

ATV61HC40N4
ATV71HC31N4

14B

ATV61HC50N4
ATV71HC40N4

15

ATV61HC63N4
ATV71HC50N4

10

ATV61HC13N4
ATV61HD90M3X
ATV71HC11N4
ATV71HD75M3X

11

ATV61HC16N4
ATV71HC13N4

12

ATV71HC16N4
ATV61HC22N4

13

ATV61HC25N4
ATV61HC31N4
ATV71HC20N4
ATV71HC25N4
ATV71HC28N4

14A

ATV61HC40N4
ATV71HC31N4

14B

ATV61HC50N4
ATV71HC40N4

15

ATV61HC63N4
ATV71HC50N4

4

1

Soft charge board
Mounting standoffs,
8/18/BM4/SNAP4
Mounting standoffs,
8/22.2/BM4/SNAP4
Mounting standoffs

Fan control board

CP4C

Discount
Schedule

3—$ Price

Catalog Number

ATV61HC16N4
ATV71HC13N4

4

VX5A1400

Frame Size

11

1
4
VX5A1300

Kit Contents

375.00

1294.00

647.00

647.00

1084.00

1220.00

126.00

160.00

67

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61/71 Spare Parts Kits and Required Documentation

Kit Contents and Required Documentation (Continued)
1—Identify Your Spare Parts Kit:
Kit Catalog Number

Kit Contents

Frame Size

Catalog Number

3—$ Price

1

Power board

10

ATV61HC13N4
ATV71HC11N4

737.00

VX5A1HC1316

Power board

1
5
4

Power board
PCBA mounting standoffs
Cable clamps

11

ATV61HC16N4
ATV71HC13N4

1235.00

VX5A1HC1622

Power board

1
5
4

Power board
PCBA mounting standoffs
Cable clamps

12

ATV71HC16N4
ATV61HC22N4

1824.00

VX5A1HC2025

Power board

1
5
5

Power board
PCBA mounting standoffs
Cable clamps

13

ATV61HC25N4
ATV71HC20N4

1824.00

VX5A1HC2531

Power board

1
5
5

Power board
PCBA mounting standoffs
Cable clamps

13

ATV71HC25N4
ATV61HC31N4

1824.00

VX5A1HC3140

Power board

1
7
1

Power board
PCBA mounting standoffs
Cable clamp

14A

ATV61HC40N4
ATV71HC31N4

2792.00

VX5A1HC4050

Power board

1
8
1

Power board
PCBA mounting standoffs
Cable clamp

14B

ATV61HC50N4
ATV71HC40N4

2846.00

VX5A1HC5063

Power board

1
8
1

Power board
PCBA mounting standoffs
Cable clamp

15

ATV61HC63N4
ATV71HC50N4

2846.00

VX5A1HD18M3X

Power board

5
4
1
1
1

Lock spacers
Screws, M4 x 10
Power board
Fan control cable
Power supply cable

6

ATV61HD18M3X
ATV71HD18M3X

486.00

Power board

5
4
1
1
1
1

Lock spacers
Screws, M4 x 10
Power board
Fan control cable
Power supply cable
Power insulate sheet

6

ATV61HD22M3X
ATV71HD22M3X

486.00

VX5A1HD22N4

Power board

5
4
1
1
1
1

Lock spacers
Screws, M4 x 10
Power board
Fan control cable
Power supply cable
Power insulate sheet

6

ATV61HD22N4
ATV71HD22N4

475.00

VX5A1HD30M3X

Power board

6
3
1
1
1

Lock spacers
Screws, M4 x 10
Power board
Fan control cable
Power insulate sheet

7B

ATV61HD30M3X
ATV71HD30M3X

459.00

VX5A1HD37M3X

Power board

6
3
1
1
1

Lock spacers
Screws, M4 x 10
Power board
Fan control cable
Power insulate sheet

7B

ATV61HD37M3X
ATV71HD37M3X

459.00

VX5A1HD45M3X

Power board

6
3
1
1
1

Lock spacers
Screws, M4 x 10
Power board
Fan control cable
Power insulate sheet

7B

ATV61HD45M3X
ATV71HD45M3X

459.00

VX5A1HD5575

Power board

1

Power board

9

ATV61HD55M3X
ATV71HD55M3X

459.00

9

ATV61HD75M3X

956.00

10

ATV61HD90M3X
ATV71HD75M3X

956.00
737.00

VX5A1HD22M3X

VX5A1HD7590

Power board

1

Power board

Power board

1

Power board

9

ATV61HD90N4
ATV61HC11N4
ATV71HD90N4

VX5A71HC13N4

Measuring board

1
5
7

Measuring board
PCBA mounting standoffs
Cable clamps

11

ATV61HC16N4
ATV71HC13N4

1147.00

VX5A71HC28N4

Power board

1
5
5

Power board
PCBA mounting standoffs
Cable clamps

13

ATV71HC28N4

1904.00

VX5IM2145M1271

Power board and power IGBTa modules

3
1
1

IGBT 1200 V, 220 A modules
Power board 30 kW, 480 V
Thermal compound

7A

ATV61HD30N4
ATV71HD30N4

1139.00

VX5IM2195M1271

Power board and power IGBT modules

3
1
1

IGBT 1200 V, 220 A modules
Power board 37 kW, 480 V
Thermal compound

7A

ATV61HD37N4
ATV71HD37N4

1139.00

VX5IM2200M1271

Power board and power IGBT modules

3
1
1

IGBT 1200 V, 300 A modules
Power board 45 kW, 480 V
Thermal compound

8

ATV61HD45N4
ATV71HD45N4

1379.00

VX5IM2300M1271

Power board and power IGBT modules

3
1
1

IGBT 1200 V, 300 A modules
Power board
Thermal compound

8

ATV61HD55N4
ATV71HD55N4

1252.00

VX5IM2400M1271

Power board and power IGBT modules

3
1
1

IGBT 1200 V, 400 A modules
Power board 75 kW, 480 V
Thermal compound

8

ATV61HD75N4
ATV71HD75N4

992.00

VX5A1HD9011

68

Qty

Power board

VX5A1HC1113

a

2—Identify Your Drive:
Description

IGBT: Insulated-gate bipolar transistor

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61/71 Spare Parts Kits and Required Documentation

Kit Contents and Required Documentation (Continued)
1—Identify Your Spare Parts Kit:
Kit Catalog Number

VY1A1105

VY1A1107

VY1A1108

VY1A1109

VY1A1202

VY1A1203

VY1A1204

VY1A1205

2—Identify Your Drive:
Description

Current sensor

Current sensor

Current sensor

Current sensor

Qty

3

1

1

1

Kit Contents

Catalog Number

9

ATV61HD75M3X
ATV61HD90N4
ATV61HD55M3X
ATV61HC11N4
ATV71HD90N4
ATV71HD55M3X

10

ATV61HC13N4
ATV61HD90M3X
ATV71HC11N4
ATV71HD75M3X

11

ATV61HC16N4
ATV71HC13N4

12

ATV71HC16N4
ATV61HC22N4

13

ATV61HC25N4
ATV61HC31N4
ATV71HC20N4
ATV71HC25N4
ATV71HC28N4

14A

ATV61HC40N4
ATV71HC31N4

14B

ATV61HC50N4
ATV71HC40N4

15

ATV61HC63N4
ATV71HC50N4

2

ATV61H075M3
ATV61HU15M3
ATV61H075N4
ATV61HU15N4
ATV61HU22N4
ATV71H075M3
ATV71HU15M3
ATV71H037M3
ATV71H075N4
ATV71HU15N4
ATV71HU22N4

33.00

3

ATV61HU22M3
ATV61HU30M3
ATV61HU40M3
ATV61HU30N4
ATV61HU40N4
ATV71HU22M3
ATV71HU30M3
ATV71HU40M3
ATV71HU30N4
ATV71HU40N4

33.00

4

ATV61HU55M3
ATV61HU55N4
ATV61HU75N4
ATV71HU55M3
ATV71HU55N4
ATV71HU75N4

52.00

5B

ATV61HD11M3X
ATV61HD15M3X
ATV61HD15N4
ATV61HD18N4
ATV71HD11M3X
ATV71HD15M3X
ATV71HD15N4
ATV71HD18N4

56.00

283.00

Motor current sensors, 314 A

Motor current sensor, 366 A

Motor current sensor, 622 A

Motor current sensor, 1188 A

Plastic parts

1
1
1
2
1
1

IP4X top cover
Wiring trap cover
Power trap cover
Side caps
Top cap
Danger label

Plastic parts

1
1
1
2
1
1
1

Front cap
Wiring trap cover
Power trap cover
Side caps
Top cap
IP4X top cover
Danger label

Plastic parts

1
1
1
1
1
2
1

Top cap
IP4X top cover
Front cap
Wiring trap cover
Power trap cover
Side caps
Danger label

Plastic parts

1
1
1
1
1
2
1

Top cap
IP4X top cover
Front cap
Wiring trap cover
Power trap cover
Side caps
Danger label

3—$ Price

Frame Size

106.00

118.00

176.00

190.00

VY1A1210

Front cover and I/O terminal cover

1

Front cover assembly

9

ATV61HD75M3X
ATV61HD90N4
ATV61HD55M3X
ATV61HC11N4
ATV71HD90N4
ATV71HD55M3X

VY1A1211

Front cover and I/O terminal cover

1

Front cover assembly

10

ATV61HC13N4
ATV61HD90M3X
ATV71HC11N4
ATV71HD75M3X

283.00

VY1A1212

Front cover assembly

1

Front cover assembly

11

ATV61HC16N4
ATV71HC13N4

441.00

12

ATV71HC16N4
ATV61HC22N4

500.00

529.00

58.00

VY1A1213

Front cover assembly

1

Front cover assembly

Front cover assembly

1

Front cover assembly

13

ATV61HC25N4
ATV61HC31N4
ATV71HC20N4
ATV71HC25N4
ATV71HC28N4

VY1A1215

Plastic parts kit

1
1
1
2
1
1
1

IP4X top cover
Front cap
Power trap cover
Side caps
Top cap
Wiring trap cover
Danger label

5A

ATV61HU75M3
ATV61HD11N4
ATV71HU75M3
ATV71HD11N4

14A
VY1A1216

Front cover assembly

1

Front cover assembly

ATV61HC40N4
ATV71HC31N4

14B

ATV61HC50N4
ATV71HC40N4

VY1A1214

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

813.00

69

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61/71 Spare Parts Kits and Required Documentation

Kit Contents and Required Documentation (Continued)
1—Identify Your Spare Parts Kit:
Kit Catalog Number

2—Identify Your Drive:
Description

Qty

Frame Size

Catalog Number

3—$ Price

Front cover assembly

1

Front cover assembly

15

ATV61HC63N4
ATV71HC50N4

1111.00

Plastic parts kit

1
1
1
1
1
1
1
1
1

EMC tray
Conduit tray
Power terminal shield
Soft charge board tray
Fan control board plate
DC reactor terminal shield
Filter board shield
Labels size 11
Danger label

11

ATV61HC16N4
ATV71HC13N4

882.00

Plastic parts kit

1
1
1
1
1
1
1

EMC tray
Conduit tray
Power terminal shield
SCR snubber board shield
Filter board shield
IT jumper warning label
Danger label

12

ATV61HC22N4
ATV71HC16N4

618.00

Plastic parts kit

1
1
1
1
1
1
1

EMC tray
Conduit tray
Power terminal shield
SCR assembly shield
Filter board shield
IT jumper warning label
Danger label

13

ATV61HC25N4
ATV61HC31N4
ATV71HC20N4
ATV71HC25N4
ATV71HC28N4

706.00

VY1A1404

EMC tray and power terminal shield

1
1

Control channel box
Terminal cover with lid

9

ATV61HD75M3X
ATV61HD90N4
ATV61HD55M3X
ATV61HC11N4
ATV71HD90N4
ATV71HD55M3X

131.00

VY1A1405

EMC tray and power terminal shield

1
1

Control channel box
Terminal cover with lid

10

ATV61HC13N4
ATV61HD90M3X
ATV71HC11N4
ATV71HD75M3X

134.00

4
6

Bus bar brackets
Insulation tubes for bus bar
brackets
Rectifier shield
Conduit tray
Right terminal shield
Left terminal shield
EMC tray
Motor control board insulator
Brake board insulator
Power board insulator
Bus plate shield
IT jumper warning label
Danger label

14A

ATV61HC40N4
ATV71HC31N4

14B

ATV61HC50N4
ATV71HC40N4

1
1
1
1
1
1
1
1
1
1
1

Bus bar brackets
Insulation tubes for bus bar
brackets
Rectifier shield
Conduit tray
Right terminal shield
Left terminal shield
EMC tray
Motor control board insulator
Brake board insulator
Power board insulator
Bus plate shield
IT jumper warning label
Danger label

15

ATV61HC63N4
ATV71HC50N4

1274.00

VY1A1217

VY1A1401

VY1A1402

VY1A1403

VY1A1406

Plastic parts kit

1
1
1
1
1
1
1
1
1
1
1
4
6

VY1A1407

Plastic parts kit

1111.00

VY1ADC1110

Capacitor assembly

1

4-capacitor assembly

9

ATV61HD90N4
ATV61HC11N4
ATV71HD90N4

628.00

VY1ADC1111

Capacitor assembly

1

6-capacitor assembly

10

ATV61HC13N4
ATV71HC11N4

910.00

11

ATV61HC16N4
ATV71HC13N4

13

ATV61HC31N4
ATV71HC25N4
ATV71HC28N4

14B

ATV61HC50N4
ATV71HC40N4

15

ATV61HC63N4
ATV71HC50N4

12

ATV71HC16N4
ATV61HC22N4

13

ATV61HC25N4
ATV71HC20N4

14A

ATV61HC40N4
ATV71HC31N4

VY1ADC1112

VY1ADC1113

VY1ADC1114

70

Kit Contents

Capacitors

Capacitors

Capacitors

6
6

8
8

Capacitors
Gaskets

Capacitors, 5200 μF / 400 V
Gaskets

6
6

Capacitors, 3600 μF / 400 V
Gaskets

1088.00

1441.00

794.00

VY1ADC1115

Capacitor assembly

1

3-capacitor assembly

9

ATV61HD75M3X
ATV61HD55M3X
ATV71HD55M3X

693.00

VY1ADC1116

Capacitor assembly

1

4-capacitor assembly

10

ATV61HD90M3X
ATV71HD75M3X

453.00

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61/71 Spare Parts Kits and Required Documentation

Kit Contents and Required Documentation (Continued)
1—Identify Your Spare Parts Kit:
Kit Catalog Number

2—Identify Your Drive:
Description

Qty

Kit Contents

3—$ Price

Frame Size

Catalog Number

107.00

Set of screws, bolts, and nuts used in the drive

9

ATV61HD75M3X
ATV61HD90N4
ATV61HD55M3X
ATV61HC11N4
ATV71HD90N4
ATV71HD55M3X

VY1ADV1105

Screw kit

1

VY1ADV1106

Screw kit

1

Set of screws, bolts, and nuts used in the drive

10

ATV61HC13N4
ATV61HD90M3X
ATV71HC11N4
ATV71HD75M3X

109.00

VY1ADV1107

Screw kit

1

Set of screws, bolts, and nuts used in the drive

11

ATV61HC16N4
ATV71HC13N4

76.00

Screw kit

1

12

ATV71HC16N4
ATV61HC22N4

76.00

13

ATV61HC25N4
ATV61HC31N4
ATV71HC20N4
ATV71HC25N4
ATV71HC28N4

76.00

14A

ATV61HC40N4
ATV71HC31N4

14B

ATV61HC50N4
ATV71HC40N4

15

ATV61HC63N4
ATV71HC50N4

13

ATV61HC25N4
ATV61HC31N4
ATV71HC20N4
ATV71HC25N4
ATV71HC28N4

14A

ATV61HC40N4
ATV71HC31N4

14B

ATV61HC50N4
ATV71HC40N4

15

ATV61HC63N4
ATV71HC50N4

11

ATV61HC16N4
ATV71HC13N4

12

ATV71HC16N4
ATV61HC22N4

14A

ATV61HC40N4
ATV71HC31N4

14B

ATV61HC50N4
ATV71HC40N4

15

ATV61HC63N4
ATV71HC50N4

9

ATV61HD75M3X
ATV61HD90N4
ATV61HD55M3X
ATV61HC11N4
ATV71HD90N4
ATV71HD55M3X

10

ATV61HC13N4
ATV61HD90M3X
ATV71HC11N4
ATV71HD75M3X

11

ATV61HC16N4
ATV71HC13N4

12

ATV71HC16N4
ATV61HC22N4

13

ATV61HC25N4
ATV61HC31N4
ATV71HC20N4
ATV71HC25N4
ATV71HC28N4

VY1ADV1108

Set of screws, bolts, and nuts used in the drive

VY1ADV1109

Screw kit

1

Set of screws, bolts, and nuts used in the drive

VY1ADV1110

Screw kit

1

Set of screws, bolts, and nuts used in the drive

VY1ADV1111

VZ3DM1600M1671

VZ3F1110

VZ3F1113

VZ3G1102

VZ3G1104

Screw kit

Diode module

Dynamic braking kit

Dynamic braking kit

Temperature sensor wire

Temperature sensor wire

1

1
1

1
1
2
2
1
1
1
1

1
6

1

2

Set of screws, bolts, and nuts used in the drive

Diode module, 600A, 1600V
Thermal compound

Braking control PCBA
Diode module, 75 A, 1200 V
Brackets
Bus bars
Input PA bus bar
Input PB bus bar
IGBT module, 600 A, 1200 V
Thermal compound

Brake board
PCB standoffs

Temperature sensor

Temperature sensors
14A

ATV61HC40N4
ATV71HC31N4

14B

ATV61HC50N4
ATV71HC40N4

15

ATV61HC63N4
ATV71HC50N4

70.00

70.00

412.00

1030.00

413.00

41.00

71.00

VZ3IM1145M1271

Braking IGBT module

1
1

IGBT module, 1200 V, 175 A
Thermal compound

7A

ATV61HD30N4
ATV61HD37N4
ATV71HD30N4
ATV71HD37N4

160.00

VZ3IM1195M0671

Braking IGBT module

1
1

IGBT module, 600 V, 250 A
Thermal compound

7B

ATV61HD30M3X
ATV71HD30M3X

154.00

7B

ATV61HD37M3X
ATV61HD45M3X
ATV71HD37M3X
ATV71HD45M3X

211.00

VZ3IM1300M0671

Braking IGBT module

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

1
1

IGBT module, 600 V, 400 A
Thermal compound

CP4C

Discount
Schedule

71

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61/71 Spare Parts Kits and Required Documentation

Kit Contents and Required Documentation (Continued)
1—Identify Your Spare Parts Kit:
Kit Catalog Number

VZ3IM1300M1271

VZ3IM1400M1271

VZ3IM1402M1271

VZ3IM1600M1271

Kit Contents

Braking IGBT module

1
1

IGBT module, 1200 V, 345 A
Thermal compound

Power IGBT module

1
1

IGBT module, 1200 V, 400 A
Thermal compound

Power IGBT module

Power IGBT module

1
1

IGBT module, 1200 V, 400 A
Thermal compound

1
1

IGBT module, 1200 V, 600 A
Thermal compound

Power IGBT module

2
1

IGBT modules, 1200 V, 600 A
Thermal compound

VZ3IM1603M1271

Power IGBT module

3
2

IGBT modules, 1200 V, 600 A
Thermal compound

Power IGBT module

4
2

IGBT modules, 1200 V, 600 A
Thermal compound

Power IGBT modules

3
1

IGBT modules, 1200 V, 220 A
Thermal compound

Power IGBT modules

3
1

IGBT modules, 600 V, 200 A
Thermal compound

Power IGBT modules

3
1

IGBT modules, 600 V, 300 A
Thermal compound

Power IGBT modules

3
1

IGBT modules, 600 V, 400 A
Thermal compound

VZ3IM2195M1271
VZ3IM2201M1271
VZ3IM2301M1271
VZ3IM2401M1271

VZ3N1205

VZ3N1206

VZ3N1207

VZ3N1301

VZ3N1302

VZ3N1307

72

Qty

VZ3IM1602M1271

VZ3IM1604M1271

a

2—Identify Your Drive:
Description

3—$ Price

Frame Size

Catalog Number

8

ATV61HD45N4
ATV61HD55N4
ATV61HD75N4
ATV71HD45N4
ATV71HD55N4
ATV71HD75N4

9

ATV61HD90N4
ATV61HC11N4
ATV71HD90N4

10

ATV61HC13N4
ATV61HC11N4

12

ATV71HC16N4
ATV61HC22N4

13

ATV61HC25N4
ATV71HC20N4

11

ATV61HC16N4
ATV71HC13N4

529.00

13

ATV61HC31N4
ATV71HC25N4
ATV71HC28N4

1059.00

14A

ATV61HC40N4
ATV71HC31N4

14B

ATV61HC50N4
ATV71HC40N4

15

ATV61HC63N4
ATV71HC50N4

1952.00

7A

ATV61HD37N4
ATV71HD37N4

223.00

7B

ATV61HD30M3X
ATV71HD30M3X

487.00

7B

ATV61HD37M3X
ATV71HD37M3X

625.00

7B

ATV61HD45M3X
ATV71HD45M3X

798.00

5B

ATV61HD11M3X
ATV61HD15M3X
ATV61HD15N4
ATV61HD18N4
ATV71HD11M3X
ATV71HD15M3X
ATV71HD15N4
ATV71HD18N4

65.00

229.00

212.00

606.00

794.00

1491.00

Power terminal block

1
1
1
1
1

Power terminal
DC warning label
Motor warning label
Input warning label (240 V)
Input warning label (480 V)

Power terminal block

1
1
1
1
1
1
1

Bottom power terminal block
Top power terminal block
DC warning label A#1
DC warning label A#2
Motor warning label
Input warning label (240 V)
Input warning label (480 V)

6

ATV61HD18M3X
ATV61HD22M3X
ATV71HD18M3X
ATV71HD22M3X
ATV61HD22N4
ATV71HD22N4

Power terminal block

1
1
1
1
1
1

Bottom power terminal block
Top power terminal block
DC warning label A#1
DC warning label A#2
Motor warning label
Input warning label

7A

ATV61HD30N4
ATV61HD37N4
ATV71HD30N4
ATV71HD37N4

229.00

Wire kita

1
1
1
1
1
1
1
1
1

Brake cable
DCCT cable
LR cable
Charge LED
Fan control cable
DR cable
Fan supply cable
PSU cable
SCR cable

6

ATV61HD18M3X
ATV61HD22M3X
ATV71HD18M3X
ATV71HD22M3X

89.00

Wire kita

1
1
1
1
1
1
1
1
1

Brake cable
DCCT cable
LR cable
Charge LED
Fan control cable
DR cable
Fan supply cable
PSU cable
SCR cable

6

ATV61HD22N4
ATV71HD22N4

86.00

Wire kita

1
3
1
1
1
1
1
1
1
1

Fan supply cable
IGBT cables
PSU cable
SCR cable
LR cable
Charge LED
DCCT cable
Brake cable
Fan control cable
DR cable

7A

ATV61HD30N4
ATV61HD37N4
ATV71HD30N4
ATV71HD37N4

179.00

Letter designations in the wire kit contents correspond to component and terminal designations on the wiring diagrams in the associated document.

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61/71 Spare Parts Kits and Required Documentation

Kit Contents and Required Documentation (Continued)
1—Identify Your Spare Parts Kit:
Kit Catalog Number

VZ3N1310

VZ3N1313

VZ3N1316

VZ3N1317

VZ3N1318

a

2—Identify Your Drive:
Description

Qty

Kit Contents

3—$ Price

Frame Size

Catalog Number

7B

ATV61HD30M3X
ATV61HD37M3X
ATV61HD45M3X
ATV71HD30M3X
ATV71HD37M3X
ATV71HD45M3X

138.00

138.00

Wire kita

1
3
1
1
1
1
1
1
1
1

Fan supply cable
IGBT cables
SCR cable
DCCT cable
LR cable
Charge LED
PSU cable
Brake cable
Fan control cable
DR cable

Wire kita

1
1
1
1
1
1
1
1
1
1

Fan supply cable
IGBT cables
SCR cable
DCCT cable
LR cable
Charge LED
PSU cable
Brake cable
Fan control cable
DR cable

8

ATV61HD45N4
ATV61HD55N4
ATV61HD75N4
ATV71HD45N4
ATV71HD55N4
ATV71HD75N4

Wire kita

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Flat cable A1:X3-A4:X31
Cable A2:X81-A4:X81
Cable A1:X8-A2:X82
Cable A4:X21/22/23-A1:X5
SCR 1 gate cable (CNL1G)
SCR 2 gate cable (CNL2G)
SCR 3 gate cable (CNL3G)
Cable RFS board X1 (Green)
Cable RFS board X4 (Red)
Cable RFS board X5 (Black)
Cable UD0-A2 X50(Blue)
Cable UD0-A4 X51 (Blue)
Cable UD(+)-A2:UD+1 Red
Cable A30:X1/2/3-A7:X1
Cable A30:X11/12/13-A2:X7
Cable A2:X10 -A31:X10/X11
Cable A6:CN2A-A1:X30/A2:X20
Cable A1:X31-A6:CN7A Cable
T1,T2,T3-A1:X11
Cable A1:X21-X31 (internal fan)
Cable A7:X2-A1:X14
Cable A1:X6
Flat cable A10:X3-A3:X3
Flat cable A1:X4-A10:X4
Flat cable A1:X2-A2:X2
Cable X3-A7:X4
DBB A20 X6 (Red)

11

ATV61HC16N4
ATV71HC13N4

382.00

Wire kita

1
1
1
2
1
1
1
1
3
2
2
1
1
1
1
1
1
1
1
1
1
1
1

Flat cable A3:X32-A4:X31
Flat cable A4:X32-A5:X31-A1:X3
Flat cable A1:X8-A3:X81
Flat cables A3/A4:X82-A4/A5:X81
SCR 1 gate cable (CNL1G)
SCR 2 gate cable (CNL2G)
SCR 3 gate cable (CNL3G)
Cable A3/A4/A5:X2-A1:X5
Cables RFS board
Cables UD0-A1/A5
Cables UD0-A3/A4/A5
Cable A1:X21-X31
Cable A30-A1/A7
Cable A7:X2-A1:X14
Cable A1:X30-A6:CN2A
Cable A1:X31-A6:CN7A
Cable T1/T2/T3-A1:X11
Cable A1:X6
Flat cable A10:X3-A3:X3
Flat cable A1:X4-A10:X4
Flat cable A1:X2-A2:X2
Cable X3-A7:X4
Connector, fan feed through

12

ATV71HC16N4
ATV61HC22N4

471.00

Wire Kita

1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2

Flat cable A3:X32-A4:X31
Flat cable A4:X32 -A5:X31- A1:X3
Flat cable A3:X82-A4:X81-A1:X8
Flat cable A4:X82-A5:X81
Cable A3/A4/A5:X2-A1:X5
SCR 1 gate cable (CNL1G)
SCR 2 gate cable (CNL2G)
SCR 3 gate cable (CNL3G)
Cable RFS board
Cables UD0-A1/ A5
Cables UD0 A3/A4/A5
Cable BU-preparation
Cable A1:X21/X22-X31/X32
Cable loom A30-A1/A7
Cable A31:X10/X11-A1
Cable T1,T2,T3-A1:X11
Cable X10-X11-X12
Cable UD0
Cable A7:X2-A1:X14
Cable A1:X30-A6:CN2A
Cable A1:X31-A6:CN7A
Cable A1:X6
Flat cable A10:X3-A2:X3
Flat cable A1:X4-A10:X4
Flat cable A1:X2-A2:X2
Cable X3-A7:X4
Connectors, fan feed through

13

ATV61HC31N4
ATV61HC25N4
ATV71HC25N4
ATV71HC28N4
ATV71HC20N4

2765.00

Letter designations in the wire kit contents correspond to component and terminal designations on the wiring diagrams in the associated document.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

73

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61/71 Spare Parts Kits and Required Documentation

Kit Contents and Required Documentation (Continued)
1—Identify Your Spare Parts Kit:
Kit Catalog Number

VZ3N1323

VZ3N1324

VZ3N1333

a

74

2—Identify Your Drive:
Description

3—
$ Price

Qty

Kit Contents

Frame Size

Catalog Number

Wire kita

4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Relay connectors
Charge LED cable w/ LED
Wire power for motor control board (CNX2)
IGBT U gate cable (CNU)
IGBT X gate cable (CNX)
IGBT V gate cable (CNV)
IGBT Y gate cable (CNY)
IGBT W gate cable (CNW)
IGBT Z gate cable (CNZ)
Thyristor R gate cable (blue wire with 2 connectors)
Braking IGBT (CNPB)
SCR1 gate cable (CNL1G)
SCR2 gate cable (CNL2G)
SCR3 gate cable (CNL3G)
Cable red sleeve (CN7)
Line sense (CN5)
SCR control cable (CN2)
Jumper (CNX5-CNX6)
Bus sense (CN6)
Current sense (red)
Current sense (white)
Current sense (blue)
Internal fan cable (CN12)
Heatsink fan cable (CN25)
Control module cable, 10 position (CNX2)
Control module cable, 26 position (CNX1)
PA power cable (red)
PB power cable (white)
Braking IGBT cable white (TAB1)
Snubber cap cable, 400 V

9

ATV61HD75M3X
ATV61HD90N4
ATV61HD55M3X
ATV61HC11N4
ATV71HD90N4
ATV71HD55M3X

244.00

Wire kita

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Relay connector
Charge LED cable w/ LED
Wire power for motor control board (CNX2)
IGBT U gate cable (CNU)
IGBT X gate cable (CNX)
IGBT V gate cable (CNV)
IGBT Y gate cable (CNY)
IGBT W gate cable (CNW)
IGBT Z gate cable (CNZ)
Thyristor R gate cable (blue wire with 2 connectors)
Braking IGBT (CNPB)
SCR1 gate cable (CNL1G)
SCR2 gate cable (CNL2G)
SCR3 gate cable (CNL3G)
Cable red sleeve (CN7)
Line sense (CN5)
SCR control cable (CN2)
Jumper (CNX5-CNX6)
Bus sense (CN6)
Current sense (red)
Current sense (white)
Current sense (blue)
Internal fan cable (CN12)
Internal fan cable (INT)
Internal fan cable (EXT)
Control module cable, 26 position (CNX1)
PA power cable (red)
PB power cable (white)
Braking IGBT cable (white) (TAB1)
Snubber cap cable, 400 V
CN13 X2 cable

10

ATV61HC13N4
ATV61HD90M3X
ATV71HC11N4
ATV71HD75M3X

242.00

Wire kita

1
1
1
1
1
1
1
1
2
1
2
1
1
1
1
1
1
2
1
2
1
1
2
1
1
1
1
1
1
1
2

Cable A30-A70-A1
Cable SCB-V31/33/35
Cable L1,L2,L3-A31
Cable A30-A70-A71
Cable A70-A71-X3
Cable A1:X7-A30/A40
Cable SCB-V31/33/35
Cable L1,L2,L3-A31,A32
Cable UD(+)-A31:X4
Cable UD(+)-A32:X11
Cable UD(-)-A31:X5
Cable A5:X62-A41:X10
Cable A70/A71-X11,X12,X13
Flat Cable A10:X3-A3:X3
Flat Cable A1:X4-A10:X4
Flat Cable A4:X82-A5:X81
Flat Cable A1:X8-A4:X81-A3:X82
Flat Cable A4:X31-A3:X32
Flat Cable A1:X3-A5:X31
Cable UD0 connectors
Cable UD0-A1:UD0
Cable UD0-A4:X52
Cable gate drive UD0 connectors
Cable A5:X53-test connector
Cable motor voltage measurement A1:X5
Cable A1:X30-A60:CN2A
Cable A1:X31-A6:CN7A
Cable A1:X30-A6:CN2A
Cable A1:X31-A6:CN7A
Cable A1:X21/X22-X30,31,32
Flat Cable A1:X2-A2:X2

14A

ATV61HC40N4
ATV71HC31N4

1135.00

Letter designations in the wire kit contents correspond to component and terminal designations on the wiring diagrams in the associated document.

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61/71 Spare Parts Kits and Required Documentation

Kit Contents and Required Documentation (Continued)
1—Identify Your Spare Parts Kit:
Kit Catalog Number

Qty

Kit Contents

Frame Size

Catalog Number

3—$ Price

Wire kita

1
1
1
1
1
3
2
1
1
1
1
1
1
2
1
2
1
1
2
1
1
1
1
1
1
1
1
2
1
1

Cable A30-A70-A71
Cable A70-A71-X3
Cable A1:X7-A30/A40
Cable SCB-V31/33/35
Cable L1,L2,L3-A31,A32
Cable UD(+)-A31/A32:X4-A32:X11
Cable UD(-)-A31:X5
Cable A5:X62-A41:X10
Cable A70/A71-X11-X14
Flat cable A10:X3-A3:X3
Flat cable A1:X4-A10:X4
Flat cable A4:X82-A5:X81
Flat cable A4:X81-A1:X8-A3:X82
Flat cable A4:X31-A3:X32
Flat cable A1:X3-A5:X31
Cable UD0 connectors
Cable UD0-A1:UD0
Cable UD0-A4:X52
Cable gate drive UD0 connectors
Cable A5:X53-test connector
Cable motor voltage measurement
Cable A1:X30-A60:CN2A
Cable A1:X31-A6:CN7A
Cable A1:X30-A6:CN2A
Cable A1:X31-A6:CN7A
Cable A1:X21/X22-X30-33
Flat cable A1:X2-A2:X2
Cable A7:X2-A1:X14
Cable A1:X6
Cable T1/T2/T3-A1:X11

15

ATV61HC63N4
ATV71HC50N4

894.00

VZ3S1910

Snubber capacitor kit

1
1
1
3
2
2
1

Snubber board
Negative DC link bus bar
Positive DC link bus bar
Snubber capacitors (1200 V-0.47 μF)
Hexagonal metal supports, M4, 20 mm length
Torx™ screws w/ captive washers, M4 x 10
Wire

9

ATV61HD90N4
ATV61HC11N4
ATV71HD90N4

407.00

Snubber capacitor kit

1
3
1
1

Snubber board
Capacitors
Snubber capacitor (1200 V-0.47 μF)
Plastic nylon tie

9

VZ3S1911

ATV61HD75M3X
ATV61HD55M3X
ATV71HD55M3X

10

ATV61HD90M3X
ATV71HD75M3X

Snubber capacitor kit

1
1
1
3
2
2
1

Snubber board
Link N thyristor
Link P thyristor
Snubber capacitors (1200 V-0.47 μF)
Hexagonal metal supports, M4, 20 mm length
Torx screws w/ captive washers, M4 x 10
Wire

10

ATV61HC13N4
ATV71HC11N4

102.00

SCR modules

3
1

Thyristor/diode modules, 1600 V, 55 A
Thermal compound

7A

ATV61HD30N4
ATV71HD30N4

44.00

7A

ATV61HD37N4
ATV71HD37N4

8

ATV61HD45N4
ATV71HD45N4

7B

ATV61HD30M3X
ATV71HD30M3X

8

ATV61HD55N4
ATV71HD55N4

7B

ATV61HD37M3X
ATV71HD37M3X

8

ATV61HD75N4
ATV71HD75N4

7B

ATV61HD45M3X
ATV71HD45M3X

309.00

9

ATV61HD90N4
ATV61HC11N4
ATV71HD90N4

310.00

10

ATV61HC13N4
ATV71HC11N4

11

ATV61HC16N4
ATV71HC13N4

VZ3N1334

VZ3S1912

VZ3TD1057M1671

VZ3TD1072M1671

VZ3TD1092M1671

VZ3TD1132M1671

VZ3TD1162M1671

a

2—Identify Your Drive:
Description

SCR modules

SCR modules

SCR modules

SCR modules

3
1

Thyristor/diode modules, 1600 V, 72 A
Thermal compound

3
1

Thyristor/diode modules, 1600 V, 92 A
Thermal compound

3
1

Thyristor/diode modules, 1600 V, 132 A
Thermal compound

3
1

Thyristor/diode modules, 1600 V, 162 A
Thermal compound

VZ3TD1250M1671

SCR module

1
1

Thyristor/diode module,1600 V, 250 A
Thermal compound

VZ3TD1285M1671

SCR module

1
1

Thyristor/diode module,1600 V, 285 A
Thermal compound

68.00

156.

155.00

290.00

353.00

Letter designations in the wire kit contents correspond to component and terminal designations on the wiring diagrams in the associated document.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

75

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61/71 Spare Parts Kits and Required Documentation

Kit Contents and Required Documentation (Continued)
1—Identify Your Spare Parts Kit:
Kit Catalog Number

2—Identify Your Drive:
Description

Qty

1
VZ3TD1330M1601

SCR module
1

VZ3TM1400M0671

VZ3TM1400M1271

VZ3TM1425M1671

VZ3TM1600M1671

VZ3V1203

VZ3V1204

Thyristor/diode module,
1200 V, 330 A
Thermal compound

Braking IGBT module

1
1

IGBT module, 600 V, 400 A
Thermal compound

Braking IGBT module

1
1

IGBT module, 1200 V, 400 A
Thermal compound

SCR module

SCR module

1
1

1
1

SCR module, 425 A, 1600 V
Thermal compound

SCR module, 600 A, 1200 V
Thermal compound

Fan kit

1
1

Fan support
Fan, 50x50x10 mm, 24 Vdc, IP21

Fan kit

1
1

Fan support
Fan, 60x60x25 mm, 24 Vdc,
IP55

3—$ Price

Frame Size

Catalog Number

9

ATV61HD75M3X
ATV61HD55M3X
ATV71HD55M3X

10

ATV61HC13N4
ATV61HD90M3X
ATV71HC11N4
ATV71HD75M3X

12

ATV71HC16N4
ATV61HC22N4

9

ATV61HD75M3X
ATV61HD55M3X
ATV71HD55M3X

9

ATV61HD90N4
ATV61HC11N4
ATV71HD90N4

10

ATV61HC13N4
ATV71HC11N4

13

ATV61HC25N4
ATV71HC20N4

14B

ATV61HC50N4
ATV71HC40N4

13

ATV61HC31N4
ATV71HC25N4
ATV71HC28N4

14A

ATV61HC40N4
ATV71HC31N4

15

ATV61HC63N4
ATV71HC50N4

2

ATV61H075M3
ATV61HU15M3
ATV61H075N4
ATV61HU15N4
ATV61HU22N4
ATV71H075M3
ATV71HU15M3
ATV71H037M3
ATV71H075N4
ATV71HU15N4
ATV71HU22N4

44.00

4

ATV61HU55M3
ATV61HU55N4
ATV61HU75N4
ATV71HU55M3
ATV71HU55N4
ATV71HU75N4

61.00

98.00

412.00

370.00

407.00

382.00

407.00

VZ3V1205

Fan kit

1
1

Fan support
Fan assembled, 80x38 mm

5B

ATV61HD11M3X
ATV61HD15M3X
ATV61HD15N4
ATV61HD18N4
ATV71HD11M3X
ATV71HD15M3X
ATV71HD15N4
ATV71HD18N4

VZ3V1206

Fan kit

2
2
4

Fans, 92x92x38 mm, 24 Vdc IP55
Fan supports
Screws with washers, M4x16

7A

ATV61HD30N4
ATV61HD37N4
ATV71HD30N4
ATV71HD37N4

104.00

Fan kit

4
1
2

Screws with washers, M4x16
Fan support
Fans, 92x92x38 mm, 24 Vdc, IP55

7B

ATV61HD30M3X
ATV61HD37M3X
ATV61HD45M3X
ATV71HD30M3X
ATV71HD37M3X
ATV71HD45M3X

137.00

Fan kit

4
1
2

Screws with washers, M4x16
Fan support
Fans, IP55

8

ATV61HD45N4
ATV61HD55N4
ATV61HD75N4
ATV71HD45N4
ATV71HD55N4
ATV71HD75N4

137.00

3

ATV61HU22M3
ATV61HU30M3
ATV61HU40M3
ATV61HU30N4
ATV61HU40N4
ATV71HU22M3
ATV71HU30M3
ATV71HU40M3
ATV71HU30N4
ATV71HU40N4

55.00

5A

ATV61HU75M3
ATV61HD11N4
ATV71HU75M3
ATV71HD11N4

78.00

6

ATV61HD18M3X
ATV61HD22M3X
ATV61HD22N4
ATV71HD18M3X
ATV71HD22M3X
ATV71HD22N4

104.00

VZ3V1207

VZ3V1208

VZ3V1209

Fan kit

1
2

Fan Support
Fans, 60x60x25 mm, 24 Vdc, IP55

VZ3V1210

Fan kit

1
1
1

Fan support
Fan, 60x25 mm
Fan, 80x38 mm

Fan kit

2
1
1

Screws with washers, M4X16
Fan support
Fan, 92x92x38 mm, 24 Vdc, IP55

VZ3V1211

76

Kit Contents

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

AC Drives and Soft Starts
Altivar™ 61/71 Spare Parts Kits and Required Documentation

Kit Contents and Required Documentation (Continued)
1—Identify Your Spare Parts Kit:
Kit Catalog Number

VZ3V1212

VZ3V1213

VZ3V1214

2—Identify Your Drive:
Description

Heatsink fan kit

Internal fan

Internal fan

Qty

1

1

1
1

VZ3V1215

Fan kit

3
1
6

VZ3V1216

Heatsink fan kit

1

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Kit Contents

Blower, 400 V

Catalog Number

10

ATV61HC13N4
ATV71HC11N4

11

ATV61HC16N4
ATV71HC13N4

12

ATV61HC22N4
ATV71HC16N4

13

ATV61HC25N4
ATV61HC31N4
ATV71HC20N4
ATV71HC25N4
ATV71HC28N4

14A

ATV61HC40N4
ATV71HC31N4

14B

ATV61HC50N4
ATV71HC40N4

15

ATV61HC63N4
ATV71HC50N4

11

ATV61HC16N4
ATV71HC13N4

12

ATV71HC16N4
ATV61HC22N4

13

ATV61HC25N4
ATV61HC31N4
ATV71HC20N4
ATV71HC25N4
ATV71HC28N4

14A

ATV61HC40N4
ATV71HC31N4

14B

ATV61HC50N4
ATV71HC40N4

15

ATV61HC63N4
ATV71HC50N4

9

ATV61HD75M3X
ATV61HD90N4
ATV61HD55M3X
ATV61HC11N4
ATV71HD90N4
ATV71HD55M3X

10

ATV61HC13N4
ATV61HD90M3X
ATV71HC11N4
ATV71HD75M3X

199.00

1278.00

Fan, 24 Vdc

Fan, 80x80
Finger guard

Fans, 92x92
Fan Support
Screws with captive washers, M4x10

9

ATV61HD75M3X
ATV61HD90N4
ATV61HD55M3X
ATV61HC11N4
ATV71HD90N4
ATV71HD55M3X

Blower, 200 V

10

ATV61HD90M3X
ATV71HD75M3X

CP4C

Discount
Schedule

3—$ Price

Frame Size

578.00

47.00

42.00

77

Pricing Guide

Renewal Parts List
Altistart™ 48 Motor Controls
Description
Control Board

Catalog Number

$ Price

VX4G481

530.00

ATS48D17Y
ATS48D22Y
ATS48D32Y
ATS48D38Y
ATS48D47Y

VX5G48D17Y
VX5G48D22Y
VX5G48D32Y
VX5G48D38Y
VX5G48D47Y

625.00
635.00
650.00
675.00
715.00

ATS48D62Y
ATS48D75Y
ATS48D88Y
ATS48C11Y
ATS48C14Y

VX5G48D62Y
VX5G48D75Y
VX5G48D88Y
VX5G48C11Y
VX5G48C14Y

840.00
900.00
1050.00
1110.00
1260.00

ATS48C17Y
ATS48C21Y
ATS48C25Y
ATS48C32Y
ATS48C41Y

VX5G48C17Y
VX5G48C21Y
VX5G48C25Y
VX5G48C32Y
VX5G48C41Y

1315.00
1425.00
1515.00
1650.00
1795.00

ATS48C48Y
ATS48C59Y
ATS48C66Y
ATS48C79Y
ATS48M10Y

VX5G48C48Y
VX5G48C59Y
VX5G48C66Y
VX5G48C79Y
VX5G48M10Y

1880.00
1975.00
2070.00
2180.00
2330.00

ATS48M12Y

VX5G48M12Y

2650.00

Filter Board

ATS48D17, D22, D32, D38, D47Y
ATS48D62, D75, D88, C11Y
ATS48C14, C17Y
ATS48C21, C25, C32Y

VX4G48161Y
VX4G48162Y
VX4G48163Y
VX4G48164Y

175.00
215.00
330.00
435.00

Firing Board

ATS48C41-C79, M10-M12Y

VX4G48165Y

340.00

SCR Power Module

ATS48D17, D22, D32Y
ATS48D38, D47Y
ATS48D62, D75Y
ATS48D88, C11Y
ATS48C14, C17Y

VZ3TM2056M18
VZ3TM2091M18
VZ3TM2132M18
VZ3TM2162M18
VZ3TM2250M18

243.00
277.00
372.00
478.00
658.00

ATS48C21, C25, C32Y
ATS48C41, C79Y
ATSC48-C66Y, M10-M12Y

VZ3TM2500M18
VZ3TP2600M18
VZ3TP2M12M18

872.00
1125.00
1495.00

Power Board

78

For Soft Start:
All ATS48 soft starts

Temperature Sensor

ATS48D17-D88Y, C11-C32Y
ATS48C41-C79Y, M10-M12Y

VZ3G001
VZ3G002

25.00
19.00

Fan

ATS48D32, D38Y
ATS48D47Y
ATS48D62-D88, C11Y
ATS48C14, C17Y
ATS48C21, C25, C32Y
ATS48C41-C79Y, M10-M12Y

VZ3V481
VZ3V4811
VZ3V482
VZ3V483
VZ3V484
VZ3V485

65.00
71.00
105.00
165.00
218.00
293.00

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

Reduced Availability
Altivar™ 58 TRX AC Drives
Description

For Use on Drives

Catalog Number

$ Price

ATV58 TRX Control Board Kit

ATV58 Type E, F, H and N

VX4A581U

625.00

ATV58 Flux Vector Control Board

FVC only

VX4A58F1

1195.00

Removable ATV58 Control Board Terminal Strips
(Includes relay terminal strip and both 9 pin and
10 pin terminal strips)

ATV58 Type E, F, H and N

VZ3N581U

25.00

Internal Fan Kit for ATV58 Frame 2 and Frame 3
(2 Fans)

ATV58..U29M2, U41M2a, U54M2, U72M2 and
ATV58..U18N4, U29N4, U41N4, U54N4,
U72N4, U90N4

VZ3V58223U

125.00

Internal Fan Kit for ATV58 Frame 4 and Frame 5
(3 Fans)

ATV58..U90M2, D12M2 and
ATV58..D12N4, D16N4, D23N4

VZ3V58245U

158.00

D
Y
E
T
C
L
I
U
B
D
A
E
R AIL
V
A
Internal Fan Kit for ATV58 Frame 6 (4 Fans)

ATV58..D16M2, D23M2 and
ATV58..D28N4, D33N4, D46N4

VZ3V58260U

198.00

Internal Fan Kit for ATV58 Frame 7 (4 Fans)

ATV58..D28M2, D33M2, D46M2 and
ATV58..D54N4, D64N4, D79N4

VZ3V58270U

235.00

Power Terminal Block for ATV58 Frame 6

ATV58..D16M2 and
ATV58..D28N4, D33N4

VZ3N58160U

155.00

Power Terminal Block for ATV58 Frame 6

ATV58..D23M2 and
ATV58..D46N4

VZ3N58165U

165.00

Power Terminal Block for ATV58 Frame 7

ATV58..D28M2, D33M2, D46M2 and
ATV58..D54N4, D64N4, D79N4

VZ3N58170U

175.00

Internal EMC Filter Kit

ATV58 ..D28N4
ATV58 ..D33N4
ATV58 ..D46N4
ATV58 ..D54N4
ATV58 ..D64N4
ATV58 ..D79N4

VX4A58861U
VX4A58862U
VX4A58863U
VX4A58871U
VX4A58872U
VX4A58873U

325.00
475.00
485.00
547.00
634.00
883.00

ATV58 ..D16M2
ATV58 ..D23M2
ATV58 ..D28M2
ATV58 ..D33M2
ATV58 ..D46M2

VX5A58D16M2U
VX5A58D23M2U
VX5A58D28M2U
VX5A58D33M2U
VX5A58D46M2U

1138.00
1138.00
1510.00
1595.00
1595.00

ATV58 ..D28N4
ATV58 ..D33N4
ATV58 ..D46N4
ATV58 ..D54N4
ATV58 ..D64N4

VX5A58D28N4U
VX5A58D33N4U
VX5A58D46N4U
VX5A58D54N4U
VX5A58D64N4U

1138.00
1138.00
1138.00
1510.00
1595.00

Replacement
Parts

Power Board

ATV58 ..D79N4

VX5A58D79N4U

1595.00

Output Transistor Kit
[Six (6) transistors included per kit]

ATV58 ..D28N4
ATV58 ..D16M2 & D33N4
ATV58 ..D23M2, D28M2 & D46N4, D54N4
ATV58 ..D33M2, D46M2 & D64N4, D79N4

VZ3IM6075M1258U
VZ3IM6100M1258U
VZ3IM6150M1258U
VZ3IM2200M1258U

740.00
905.00
1036.00
1308.00

Dynamic Braking Transistor

ATV58 ..D16M2, D23M2, & D28N4, D33N4, D46N4 VZ3IM1050M1258U
ATV58 ..D28M2 & D54N4
VZ3IM1100M1258U
ATV58 ..D33M2, D46M2 & D64N4, D79N4
VZ3IM1150M1258U

310.00
340.00
380.00

Input Diode/Thyristor Bridge Kit for all three (3) phases

ATV58 ..D16M2, & D28N4, D33N4
ATV58 ..D23M2, D28M2 & D46N4, D54N4
ATV58 ..D33M2, D46M2 & D64N4, D79N4

410.00
456.00
520.00

VZ3TD1055M1658U
VZ3TD1090M1658U
VZ3TD1130M1658U

a
This kit can be used on ATV58..U41M2 product with a date code of 0126 or later. ATV58..U41M2 product manufactured prior to this date had the fan
leads soldered to the power board and should be sent to the factory for repair or exchange.
Note: We anticipate offering renewal parts for 5 years through 2012. The ATV61 and ATV71 AC drive should be used in new applications.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

79

Pricing Guide

Renewal Parts List
Altivar™ 58 TRX AC Drives
Description

For Use on Drives

Catalog Number
VX4A381

$ Price

Control Board

ATV58H..C10N4–C33N4

Interface Board

ATV58H.. C10N4–C33N4

VX4A382a

680.00
300.00

Gate Drive Board

ATV58H.. C10N4–C33N4

VX5A38C10N4a

820.00

Gate Board

ATV58H.. C10N4

VX5A38C11a

180.00

Current Gait Board

ATV58H.. C10N4
ATV58H..C13N4–C15N4 and C25N4
ATV58H.. C19N4
ATV58H.. C23N4 and C28N4
ATV58H.. C31N4
ATV58H.. C33N4

VX5A38C12a
VX5A38C13N4a
VX5A38C14a
VX5A38C15N4a
VX5A38C16a
VX5A38C17a

400.00
400.00
400.00
400.00
400.00
400.00

D
Y
E
T
C
L
I
U
B
D
A
E
R AIL
V
A
Pre-Charge Contactor Kit

ATV58H.. C10N4
ATV58H.. C13N4
ATV58H.. C15N4–C19N4
ATV58H.. C23N4–C33N4

VY1A38101a
VY1A38102a
VY1A38103a
VY1A38104a

360.00
370.00
890.00
1565.00

Current Transformer

ATV58H.. C10N4
ATV58H.. C13N4
ATV58H.. C15N4–C19N4
ATV58H.. C23N4–C25N4
ATV58H.. C28N4–C33N4

VY1A38111a
VY1A38112a
VY1A38113a
VY1A38114a
VY1A38115a

100.00
100.00
100.00
260.00
260.00

Power Supply Board

ATV58H.. C10N4–C33N4

VY1A38120a

820.00

Insulating Sheets

ATV58H.. C10N4
ATV58H.. C13N4–C19N4
ATV58H.. C23N4–C33N4

VY1A38210a
VY1A38211a
VY1A38212a

120.00
240.00
320.00

VY1A58856a

80.00

Screw Kit

ATV58H.. C10N4
ATV58H.. C13N4
ATV58H.. C15N4
ATV58H.. C19N4
ATV58H.. C23N4–C25N4
ATV58H.. C28N4–C33N4

VY1ADV384a
VY1ADV385a
VY1ADV386a
VY1ADV387a
VY1ADV388a
VY1ADV389a

85.00
100.00
100.00
100.00
150.00
160.00

Capacitor Kit

ATV58H.. C10N4
ATV58H.. C13N4–C19N4
ATV58H.. C23N4–25
ATV58H.. C28N4–C33N4

VZ3C3810a
VZ3C3811a
VZ3C3812a
VZ3C3813a

2455.00
3560.00
6230.00
7350.00

Input Diode Bridge

ATV58H.. C10N4–C33N4

VZ3D381a

345.00

Input Filter

ATV58H.. C10N4–C33N4

VZ3D382a

145.00

Power Fuse

ATV58H.. C10N4
ATV58H.. C13N4–C19N4
ATV58H.. C23N4–25
ATV58H.. C28N4–C33N4

VZ3F3801a
VZ3F3802a
VZ3F3804a
VZ3F3803a

305.00
320.00
565.00
565.00

Thermal Sensor

ATV58H.. C10N4–C33N4

VZ3G381a

180.00

Output Transistor

ATV58H.. C10N4

VZ3I381a

1120.00

Output Transistor Kit

ATV58H.. C13N4–C19N4
ATV58H.. C23N4–C25N4
ATV58H.. C28N4–C33N4

VZ3I382a
VZ3I383a
VZ3I384a

2225.00
4305.00
5340.00

Internal Cable Kit

ATV58H.. C10N4
ATV58H.. C13N4–C19N4
ATV58H.. C23N4–C33N4

VZ3N3808a
VZ3N3809a
VZ3N3810a

455.00
475.00
1040.00

Pre-Charge Resistor

ATV58H.. C10N4
ATV58H.. C13N4–C19N4
ATV58H.. C23N4–C33N4

VZ3R3810a
VZ3R3811a
VZ3R3812a

335.00
195.00
240.00

Control Transformer

ATV58H.. C10N4
ATV58H.. C13N4–C19N4
ATV58H.. C23N4–C33N4

VZ3TR381a
VZ3TR382a
VZ3TR383a

180.00
305.00
350.00

Heatsink Fans

ATV58H.. C10N4
ATV58H.. C13N4–C19N4
ATV58H.. C23N4–C33N4

VZ3V3808a
VZ3V3809a
VZ3V3810a

675.00
970.00
1780.00

Internal Fan Kit

ATV58H.. C10N4–C19N4
ATV58H.. C19N4
ATV58H.. C23N4–C33N4

VZ3V3818a
VZ3V3819a
VZ3V3820a

120.00
60.00
225.00

Thermal Grease

Replacement
Parts
(For ATV58
Type H 125 hp
to 500 hp VT)

Note: We anticipate offering renewal parts for 5 years through 2012. The ATV61 and ATV71 AC drive should be used in new applications.
a
Must contact Schneider Electric Services Division for replacement.

80

CP4C

Discount
Schedule

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Pricing Guide

Renewal Parts List
Altivar™ 58 TRX AC Drives

Table 67:

Options—Field Installed
Description

For Use on Drives

Keypad
Keypad Remote Mount Kit (IP65 rating)
Power Suite test & commissioning software for PC & PPC on CD
PowerSuite™ upgrade CD from most recent to new version
PC Cable connection kit to connect to PC to drive
Operator
Interface

Operator Interface Options

Application
Option Cards

Communication

Communication Options

Fan Kit

Pocket PC connection kit to connect hp Jornada to drive
Closing Plate Kit
Keypad Mount Kit
Operator, mounting collar, 2.5 kilohm, 1⁄2 watt potentiometer
Analog I/O Option Card
Provides 2 Logic Inputs, 1 Logic Output, 1 Analog Output, and
1 Bi-polar Analog Input
Digital I/O Option Card
Provides 2 Logic Inputs, 1 Logic Output, 1 Analog Output, and
A,A-,B,B- Logic Inputs for
Encoder Speed Feedback.
General Purpose Option Card
Provides 1 Form C Relay Output and 3 Analog Outputs
Pump Switching Card
Sequences up to five pumps with one ATV58
115 Vac ATV58 Logic Input Module
Provides 115 Vac conversion for logic inputs LI1,LI2, LI3 & LI4
0–10 volt to 4–20 mA Adapter Card
FIPIO™ Communication Card
Modbus™ + Communication Card
Modbus/Uni-Telway™ Communication Card
Interbus™ S Communication Card
RS485 Cable w/ Modbus Mapping Guide
Profibus DP Communication Card
Device Net Communication Card
Ethernet Modbus TCP/IP Communication Card
FIPIO Communication Card
LonWorks® to Modbus DIN Rail Mount Gateway
Johnson Controls N2 Communication Card

Ventilation Fan Kit
These kits mount directly to the top of the
ATV58 Type H and Type FVC products.
They are powered from the drive.

DB Transistor

Ventilation Fan Kits

Catalog Number

$ Price

VW3A58101U
VW3A58103
VW3A8104
VW3A8105
VW3A8106

115.00
125.00
150.00
98.00
75.00

TCSMCNAM3M002P

52.00

ATV58 Type N
ATV58 Type N
All Altivar drives

VW3A58836
VW3A58837
ATVPOT25K

25.00
55.00
69.00

ATV58 Type E, F, H, N and FVC

VW3A58201U

200.00

ATV58 Type E, F, H, N and FVC

VW3A58202U

200.00

ATV58 Type E, F, H and N

VW3A58253U

350.00

D
Y
E
T
C
L
I
U
B
D
A
E
R AIL
V
A

I/O Extension
Cards

I/O Extension Cards

USB to RJ45 Adaptor Kit
For use in connecting to a PC with a USB port

ATV58 Type E, F, H, N and FVC
ATV58 Type H and FVC
ATV58 all types
ATV58 all types
ATV58 all types
Advantys™ OTB, Altistart™ motor
starters, Altivar™ series incl. HMI,

Braking
Components

Protected DB Resistors in Type 1 Enclosure.
For use with ATV58 Type E, F, FVC, H and N.

Line Reactor for Single-Phase Input
IP00 Rating for use with ATV58 Type E, F, H and N

Conduit Entrance Kits

EMC Wiring Plate
Assist in compliance with Level A EMC directive.
These plates are used to land the shield of shielded
motor cables. For use with ATV58 Type FVC and Type H.
Hardware

Conduit Entrance Kit
These kits have various sized knockouts to land
conduit and provide wire bending space to wire line
and load cables. For use with ATV58 Type FVC and Type H.

ATV58 Type E, F, H and N

VW3A58210U

550.00

ATV58 Type H and N

VW3A58275U

195.00

3115829750
VW3A58301U
VW3A58302U
VW3A58303U
VW3A58304EU
VW3A58306U
VW3A58307U
VW3A58309U
VW3A58310U
VW3A58311U
VW3A58312PU
VW3A58354U
VW3A58821

175.00
550.00
550.00
300.00
550.00
50.00
550.00
550.00
550.00
550.00
495.00
300.00
100.00

VW3A58822

100.00

VW3A58823

150.00

VW3A58824

175.00

VW3A58825

195.00

VW3A58826

225.00

VW3A58701

280.00

VW3A66711

422.00

VW3A66712

633.00

ATV58 all types
ATV58 Type E, F, Ha and N
ATV58 Type E, F, H, N and FVC
ATV58 Type E, F, H, N and FVC
ATV58 Type E, F, H, N and FVC
ATV58 Type E, F, H, N and FVC
ATV58 Type E, F, H, N and FVC
ATV58 Type E, F, H, N and FVC
ATV58 Type E, F, H, N and FVC
ATV58 Type H 125–500 hp and FVC
ATV58 Type E, F, H and N
ATV58 Type E, F, H and N
ATV58..U09M2, U18M2
ATV58..U29M2, U41M2 and
ATV58..U18N4, U29N4, U41N4
ATV58..U54M2, U72M2 and
ATV58..U54N4, U72N4, U90N4
ATV58..U90M2, D12M2 and
ATV58..D12N4, D16N4, D23N4
ATV58..D16M2, D23M2 and
ATV58..D28N4, D33N4, D46N4
ATV58..D28M2, D33M2, D46M2 and
ATV58..D54N4, D64N4, D79N4
ATV58..U09M2, U18M2
ATV58..U09M2, U18M2: U18N4,
U29N4, U41N4, U54N4, U72N4
ATV58..U29M2, U41M2: U90N4,
D12N4
ATV58..U54M2, U72M2: D16N4,
D23N4
ATV58..U90M2, D12M2 and
ATV58..D28N4, D33N4, D46N4
ATV58..D16M2, D23M2 and
ATV58..D54N4
ATV58..D28M2, D33M2, D46M2 and
ATV58..D64N4, D79N4
ATV58..U09M2, U18M2, U29M2,
U41M2, U72M2
ATV58..U90M2, D12M2
ATV58..U09M2, U18M2
ATV58..U29M2, U41M2 and
ATV58..U18N4, U29N4, U41N4
ATV58..U54M2, U72M2 and
ATV58..U54N4, U72N4, U90N4
ATV58..U90M2, D12M2 and
ATV58..D12N4, D16N4, D23N4
ATV58..U09M2, U18M2
ATV58..U29M2, U41M2 and
ATV58..U18N4, U29N4, U41N4
ATV58..U54M2, U72M2 and
ATV58..U54N4, U72N4, U90N4
ATV58..U90M2, D12M2 and
ATV58..D12N4, D16N4, D23N4
ATV58..D16M2, D23M2 and
ATV58..D28N4, D33N4, D46N4
ATV58..D28M2, D33M2, D46M2 and
ATV58..D54N4, D64N4, D79N4

VW3A66713

950.00

VW3A66714

1266.00

VW3A66715

1846.00

VW3A66716

2321.00

VW3A58501

350.00

VW3A58502
VW3A58831

380.00
25.00

VW3A58832

25.00

VW3A58833

25.00

VW3A58834

25.00

VW3A58842

45.00

VW3A58843

45.00

VW3A58844

45.00

VW3A58845

45.00

VW3A58846

65.00

VW3A58847

65.00

1

a
PL7 Software provides pre-defined configuration selections for /2 to 100 hp Type H products.
Note: Note: We anticipate offering renewal parts for 5 years through 2012. The ATV61 and ATV71 AC drive should be used in new applications.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

CP4C

Discount
Schedule

81

Pricing Guide

AC Drives and Soft Starts
Auxiliary Services

Drive Product Support Group

Approval Drawings

For support and assistance, contact the Drive Product Support Group.
The Drive Product Support Group is staffed from 8:00 am until 6:00 pm
Eastern time to assist with product selection, start-up, and diagnosis of
product or application problems.
EMERGENCY Technical phone support is available 24 hours a day, 365
days a year.
Toll Free:
1-888-778-2733
E-mail:
drive.products.support@us.schneider-electric.com
Fax:
919-217-6508

Standard approval drawings are available for the enclosed drives and
soft starts. The price adder for custom approval drawings are listed in
the table below.
NOTE: Before manufacturing of the enclosed drive/soft start can
begin, the approving parties must stamp and sign the
transmittal forms that accompany the drawings. In the unlikely
event that approval drawings are not approved and must be
resubmitted, the approving parties must mark up, stamp and
sign the drawings before a second set of approval drawings
can be submitted.

Schneider Electric Service (On-Site)
The Schneider Electric Services division is committed to providing
quality on-site service that consistently meets customer expectations.
Services responds to your requests, seven days a week, 24 hours a
day. Phone: 1-888-778-2733

Schneider Electric Customer Training
Schneider Electric offers a variety of instructor-led skill enhancing and
technical product training programs for customers. For a complete list of
drives/soft start training with dates, locations and pricing please call:
Phone:
978-975-9306
Fax:
978-975-2821

Record Drawings
Record drawings are available for the enclosed drives and soft starts.
The price adders for record drawings are listed in the table below.
Table 63: Pricing a
Approval Drawings b
Drawing Size

One set per drive
c
$ Price

DVD d
$ Price

Record Drawings
One set per drive
c
$ Price

DVD d
$ Price

A

8.5 x 11

250.00 net

350.00 net

175.00 net

270.00 net

Customer Care Center

B

11 x 17

250.00 net

350.00 net

175.00 net

270.00 net

(Assist with stock checks, assist with claims, and assist with order
management issues)

C

17 x 22

250.00 net

350.00 net

175.00 net

270.00 net

To provide additional support, Schneider Electric has rolled out new
Technical Service Representatives in local offices which have the
strongest needs.
Due to time zone changes and different time operation requirements,
business operation times vary.
Phone:
888-778-2733
Fax:
888-329-9773
Web Address: http://www.schneider-electric.us

a
b
c
d

Table 64: Schneider Electric Services Drives Start-up Pricing
Schneider Electric Service offers standard pricing for start-up under
conditions as described below. The pricing is for Drives and Soft Starts
located within the U.S., excluding Alaska and Hawaii.
Call 1-888-Square D for scheduling.

Literature Fulfillment Center
To obtain support literature for your product or application needs,
contact the Schneider Electric Literature Fulfillment Center.
Phone:
800-888-2448
Fax:
920-766-6675
E-mail:
SquareD@banta.com

Documentation, Start-up and Training
Standard Documentation
Each AC Drive or Soft Start shipped includes one set of instruction
bulletins. Additional instruction bulletins are available for $30.00 net
each. Each set of instruction bulletins includes installation, start-up,
trouble shooting and wiring diagram information. Separate Approval
and/or Record Drawings are not included.

82

Enter drawing requirement as a separate line item on purchase order.
Pricing for Approval Drawings include pricing for Record Drawings
One set equals a maximum of 8 copies. Additional copies are available at $75.00 net
each.
The drawings are available in several formats. They are. DWG; .DXF; .IGS; and Microcad.

Service

Standard Price
(Work Performed on weekdays
during normal business hours)
$ Price

On Site Labor
Traveland Expense

$165.00/Drive
See Below

Premium Price
(Work performed outside of
normal business hours, Saturday,
Sunday or Holidays)
$ Price
$300.00/Drive
See Below

Notes:

•
•

Maximum of six drives or soft starts can be tested per day.
When less than three days (72 hours) notice of start-up date is provided, the
premium rate will be charged.

Travel Time and Expenses
Travel time and expenses will be calculated based on actual “round trip”
mileage traveling from the Schneider Electric Sales Office to the job site
and return.
Travel and living expenses will be billed at cost plus an administrative
charge.
Travel and expense pricing will be based on actual number of trips with
travel charges applied to each separate trip Schneider Electric Service
makes to the job site.

© 2012 Schneider Electric All Rights Reserved
Prices subject to change without notice.
01/2012

Schneider Electric USA, Inc.
8001 Knightdale Blvd.
Knightdale, NC 27545
1-888-778-2733
www.schneider-electric.us

Advantys™, Altistart™, Altivar™, E-Flex™, FIPIO™, M-Flex™, Modbus™, PowerGard™,
PowerLogic™, PowerSuite™, Sepam™, S-Flex™, SoMove™, Square D™, TCS™, TeSys™,
and Uni-Telway™ are trademarks or registered tradmarks of Schneider Electric or its affiliates in
the United States and other countries. Other trademarks used herein are the property of their
respective owners.
8800PL9701R01/12 © 2012 Schneider Electric All Rights Reserved
Replaces 8800PL9701R11/11 dated 11/2011
01/2012



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Create Date                     : 2012:02:23 12:32:00-05:00
Creator                         : FrameMaker 9.0
Modify Date                     : 2012:06:10 11:16:00-05:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : FrameMaker 9.0
Metadata Date                   : 2012:06:10 11:16-05:00
Producer                        : www.adlibsoftware.com:EXS41012-Windows 2008 R2:TNG
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:88425cd0-b714-4ac3-87cd-6f3678c105b7
Instance ID                     : uuid:0c81f5d3-3a5c-48bf-8b39-26df26cd63ac
Page Layout                     : SinglePage
Page Mode                       : UseNone
Page Count                      : 83
EXIF Metadata provided by EXIF.tools

Navigation menu