Mechanical

BURNDY®

TABLE OF CONTENTS
Types KS, KS-3, SC

A-3

Type K2A-U

A-25

Type KSU

A-4

Types K3A-U, KK3A-U

A-26

Type KSA

A-5

Types KVS, KVSU

A-6

Types K4A-U, KK4A-U,
K11A-U, K21A-U, K22A-U

A-27

Types KVSW, KVS-A

A-1

UL Listed Distribution
Blocks

A-47
to
A-50

Power Distribution Blocks,
Splice/Reducer Blocks

A-51
to
A-55

Types BIT, BITO, BISR

A-56

A-7

Types K6A-U, K8A-U,
KK6A-U, KK8A-U

A-28

Type QPX

A-8

Type KAU-KIT

A-29

Type BIBS

A-57

Type QPX-Y

A-9

Type K-AG1

A-30

Type BIBD

A-58

Types KPA, KPA-UP

A-10

Type K-G1

A-31

Types BIBS-MT, BIBD-MT

A-59

Type KLU

A-11

Type AMS

A-32

Type 1PL

A-60

Types KA, EA

A-12

Types AGSKIT, UGSKIT

A-33

Type BWTE

A-61

Type BGBL

A-13

Type BIBS-DB

A-34

Type BPTE

A-62

Types UGSKIT8,
UGS350ULDB

A-35

Type BISR-DB

A-36

Types QGFL, FCB

A-37

Types KPU-AC, UCU-AC

A-38

Type BIPC

A-39

Terminal Blocks

A-40

U-BLOK and Platforms

A-41,
A-42

Types CL50-1, CL50-1TN, CL A-14
Types QA, QQA

A-15

Types Q2A, Q3A

A-16

Types QB, Q2B

A-17

Types QDA, QR

A-18

Types VT, E-C-G

A-19

Types VA, VVA

A-20

Type HFB-P1

A-21

Type HFB-N

A-22

Types KA-U, KKA-U

A-23

Type KA-UAR

A-24

™

SPEC-BLOK

™

A-43
to
A-46

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-2

BURNDY®

LIGHTNING PROTECTION INFO.
Basic rules for selection are:
1.	
2.	
3.	
4.	

Must be like material to the conductor.
Two bolts to ground rod - minimum.
Cable to cable connections can be anything,
one bolt, two bolt, compression, etc.
Cable to steel structure must have 8 square
inch contact with steel.

5.	
6.	

Heavy duty stacks - mechanical only.
On all connectors with heavy duty stack
rating, we must offer 1/16” thick lead plating
as an option. The reason for that is closest
25 ft. to stack opening must use lead coated
product.

SPECIAL FEATURES
Other features are also available for products
listed, such as undrilled or special drilling, 45° or
90° pad angles, belling for extra flexible cable,
smooth or special threaded studs, special label-

REVOLUTIONARY
BURNDY® DESIGN
MEETS STRICT UL486B
STANDARDS

ing or packaging, extra long braid, and nuclear
certification. Please contact BURNDY Customer
Service for any inquiries.

... and puts the bite on
aluminum connections
forever!

For use on all combinations
•	
•	
•	

Aluminum to aluminum
Aluminum to copper
Copper to copper

Complies with NFPA 78-86 Ordinary Structures.
Complies with NFPA 78-86 Heavy Duty
Stacks. (Order: LD for Lead Plating for Heavy
Duty Stack applications.)

ALL OTHER SPECIAL REQUESTS
PLEASE CONTACT
BURNDY CUSTOMER SERVICE
1-800-346-4175

Unique “bite and grip”
TRITAP™ SERVIT® contact
delivers safe, long-term
reliability — even without
scratch brushing ... without
oxide inhibiting compounds.†
† When used in NEC applications of insulated
cables only.

Patented

Available in sizes from #10 through 500 kcmil

Triangular edges bite into
cable to break through
surface oxides:
•	
provide low contact
resistance
•	
produces gas tight
seal

Spacer provides built-in
separation to retard
galvanic corrosion

Tin-plated contact
surface inhibits oxide
formation

Anti-galling, high
efficiency threaded
components result
in high contact force.
Easily installed using
standard, everyday
wrenches.

Special heat-treated hard,
aluminum alloy

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPES KS & KS-3

A-3

SERVIT®
For Copper, Copperweld
Compact, high strength, high copper alloy SERVIT®
split-bolt has free-running threads and easy to grip
wrench flats. Highly resistant to season cracking
and corrosion, the SERVIT® provides maximum
pressure and assures a secure connection on
all combinations of run and tap conductors. Type
KS-3 accommodates 3 maximum size conductors.

Catalog
Number

Cross
Flats

† KS90
† KS15
† KS17
* KS17-3
† KS20
* KS20-3
† KS22
* KS22-3
† KS23
† KS25
† KS26
† KS27
† KS29
† KS31
† KS34
KS39
KS44

L

0.50
0.50
0.63
0.62
0.69
0.68
0.75
0.74
0.82
0.94
1.05
1.36
1.36
1.70
1.82
2.31
2.56

0.85
0.85
1.14
0.98
1.20
1.17
1.50
1.33
1.54
1.77
1.94
1.86
2.07
2.51
2.79
3.29
3.73

W
0.38
0.38
0.45
0.70
0.51
0.78
0.60
0.84
0.62
0.73
0.82
1.17
1.17
1.41
1.48
1.94
2.19

Conductor

Copper

▲

Copperweld
Maximum Run and Tap

Equal Run & Tap

Min Tap with
Max Run

Sol.

Str.

Type A

Type D

Recommended
Tightening
Torque (in-lb)

12 - 10 Str.
10 - 8 Str.
8 Str. - 6 Sol.
8 Str. - 6 Sol.
8 Str. - 4 Sol.
8 Str. - 4 Sol.
6 Str. - 2 Sol.
6 Str. - 2 Sol.
6 Str. - 2 Str.
4 Str. - 1/0 Str.
2 Str. - 2/0 Str.
1 Str. - 3/0 Str.
1 Str. - 250
1/0 Str. - 350
2/0 Str. - 500
4/0 Str. - 750
300 - 1000

16 Str.
14 Str.
14 Str.
16 Str.
14 Str.
14 Str.
14 Str.
14 Str.
14 Str.
14 Str.
14 Str.
8 Sol.
8 Str.
1/0 Str.
2/0 Str.
4/0 Str.
4/0 Str.

#10
#8
#6
#6
#4
#4
#2
#2
#1
2/0
3/0
—
4/0
—
—
—
—

—
—
3 #12
3 #12
3 #10
3 #10
3 #8
3 #8
3 #7
3 #5
7 #7
—
7 #5
19 #8
19 #6
19 #5
—

—
—
8A
8A
6A
6A
4A
4A
3A
2A
—
—
—
—
—
—
—

—
—
9-1/2D
9-1/2D
8D
8D
6D
6D
5D
4D
—
—
—
—
—
—
—

80
80
165
165
165
165
275
275
275
385
385
500
650
650
825
1000
1100

▲ Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor combinations.
See note LIGHTNING PROTECTION INFO.
* Not UL Listed or CSA Certified.
† In addition to UL Listed for wire connectors and CSA Certified, these items are also UL rated for direct burial.

TYPE SC
SERVIT® COVER
HUG-A-BUG
Used indoors or outdoors, this compact, one-piece
plastic SERVIT® cover saves time and material,
eliminates costly taping of split-bolts. Positive latch
snaps easily and quickly over connector, ideal for
tight quarters. Self-positioning plastic fingers wrap
around wires fully insulating joint. UL Listed for 600
volt indoor application with type KS. Three covers
accommodate a range of 6 SERVIT® sizes through
2/0 Str.

Catalog
Number

For Use With

SC4

KS17, KS17-3, KS20, KSU17, KSU20

SC2

KS22, KS20-3, KS23, KS22-3, KSA6, KSA4,
KSU22, KSU23

SC2/0

KS25, KS26, KSA2, KSA1/0, KSU25, KSU26

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-4

BURNDY®

TYPE KSU
UNIVERSAL SERVIT®
For Use On All Combinations of
Copper, Aluminum, ACSR, AAAC,
5005, and Steel
Tin-plated, high strength, copper alloy SERVIT®
with spacer. Spacer separates dissimilar
conductors and provides long contact length that
prevents high pressure point contacts between run
and tap conductors.

Copper Only

486A
Copper Only

Use of PENETROX™ joint compound
recommended with Aluminum and ACSR.
Conductor

Catalog
Number

Cross
Flats

L

KSU17

0.62

0.92

KSU20

0.69

KSU22

Run

W

Steel
(Max Conductor)

Tap

Recommended
Tightening
Torque (in-lb)

Copper &
Aluminum

ACSR
AAAC
5005

Copper &
Aluminum

ACSR AAAC
5005

Sol.
BWG

3 Str.
BWG

Nom.
Dia.

0.42

12 Sol. - 6 Sol.

8 (6-1)

12 Sol. - 6 Sol.

8 (6-1)

8

—

5/32

165

1.05

0.48

10 Sol. - 4 Sol.

6 (6-1)

10 Sol. - 4 Sol.

6 (6-1)

6

8

7/32

165

0.74

1.25

0.57

10 Sol. - 2 Sol.

6 (6-1) 4 (7-1)

10 Sol. - 2 Sol.

6 (6-1) - 4 (7-1)

4

6

1/4

275

KSU23

0.81

1.48

0.59

8 Str. - 2 Str.

3 (6-1) 2 (6-1)

8 Sol. - 2 Str.

6 (6-1) - 2 (6-1)

—

4

5/16

275

KSU25

0.93

1.77

0.70

2 Str. - 1/0 Str.

3 (6-1) 1 (6-1)

10 Str. - 1/0 Str.

6 (6-1) - 1 (6-1)

—

—

3/8

385

KSU26

1.04

1.93

0.79

2 Str.-2/0 Str.

1 (6-1) 1/0 (6-1)

8 Str. - 2/0 Str.

6 (6-1) - 1/0 (6-1)

—

—

7/16

385

KSU27

1.38

2.34

1.12

1 Str. - 3/0 Str.

1 (6-1) 2/0 (6-1)

8 Sol. - 3/0 Str.

8 (6-1) - 2/0 (6-1)

—

—

1/2

500

KSU29

1.38

2.50

1.58

1Str. -250 kcmil

2/0 (6-1) 4/0 (6-1)

8 Str. - 250

6 (6-1) - 4/0 (6-1)

—

—

1/2

650

KSU31

1.69

2.88

1.36

1/0 Str. 350 kcmil

3/0 (6-1) 4/0 (6-1)

4 Str. - 350

4 (6-1) - 4/0 (6-1)

—

—

5/8

650

KSU34

2.00

3.12

1.47

400 - 500 kcmil

336 (30-7) 477 (18-1)

2 Str. - 500

2 (6-1) - 477
(18-1)

—

—

—

825

Accommodates compressed conductors within conductor ranges.
See note LIGHTNING PROTECTION INFO.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE KSA

A-5

TRITAP™ SERVIT®
For All Combinations of Aluminum to
Aluminum, Aluminum to Copper and
Copper to Copper, Aluminum Alloy Tin
Plated
PATENTED TRIANGULAR
PENETRATION TECHNOLOGY
CONTACT

Catalog
Number

Cross
Flats

L

W

KSA6

0.75

1.58

KSA4

0.81

KSA2

Features & Benefits
• No scratch brushing required.
• No oxide inhibitor required.
• Orients the conductor.
• Provides maximum pressure and
assures a secure connection of run and
tap conductors.
• Facilitates piercing the aluminum
conductor surface oxides.
• UL 486B listed, 90°C rated.
• Provides a low contact resistance.
• Provides equal coefficient of expansion
• Inhibits the reformation of oxides by
producing a gas-tight seal.
• Provides improved retention of minimum
to maximum conductor combinations.

Alum. to Alum., Alum. to Copper, Copper to Copper Conductors

Recommended
▲ Tightening
Torque (in-lb)

Max Run to Max Tap

Min Run to Min Tap

Max Run to Min Tap

0.56

#6 Str. (0.184) #6 Str. (0.184)

#10 Sol. (0.102) #10 Sol. (0.102)

#6 Str. (0.184) #10 Sol. (0.102)

165

1.38

0.62

#4 Str. (0.232) #4 Str. (0.232)

#8 Sol. (0.129) #10 Sol. (0.102)

#4 Str. (0.232) #10 Sol. (0.102)

165

0.94

1.58

0.69

#2 Str. (0.292) #2 Str. (0.292)

#6 Sol. (0.169) #8 Str. (0.146)

#2 Str. (0.292) #8 Sol. (0.146)

275

KSA1/0

1.00

1.92

0.75

#1/0 Str. (0.373) #1/0 Str. (0.373)

#2 Str. Compact (0.268) #8 Sol. (0.129)

#1/0 Str. (0.373) #8 Sol. (0.129)

385

KSA2/0

1.12

1.92

0.88

#2/0 Str. (0.418) #2/0 Str. (0.418)

#2 Str. Compact (0.268) #8 Str. (0.146)

#2/0 Str. (0.418) #8 Str. (0.146)

385

KSA4/0

1.49

2.54

1.13

#4/0 Str. (0.528) #4/0 Str. (0.528)

#2 Str. Compact (0.268) $6 Str. (0.184)

#4/0 Str. (0.528) $6 Str. (0.184)

500

KSA350

1.69

3.24

1.50

350 kcmil (0.681) 350 kcmil (0.681)

#1/0 Str. Compact (0.336) #4 Str. (0.232)

350 kcmil (0.681) #4 Str. (0.232)

650

KSA500

2.00

3.62

1.73

500 kcmil (0.813) 500 kcmil (0.813)

400 kcmil Compact (0.659) #2 Str. Compact (0.268)

500 kcmil (0.813) #2 Str. Compact (0.268)

825

▲ Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor combinations.
** No scratch brushing or oxide inhibiting compounds required for insulated 90° C max. rated conductor for N.E.C. applications.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-6

BURNDY®

TYPE KVS
OKLIP™
Copper & Copperweld
Compact, two-piece, high strength, high copper
alloy BURNDY® OKLIP™ recommended for heavy
duty connections. Neoprene rings hold DURIUM™
bolts in place during installation. Installed with
ordinary wrench.
Conductor
Catalog
Number

Copperweld
Max Run & Tap
Str.
7 #8
7 #6
19 #8
19 #6
19 #5
—

Copper
Run
2 Str. - 2/0 Str.
1/0 Str. - 4/0 Str.
250 - 350 kcmil
400 - 500 kcmil
400- 800 kcmil
500 - 1000 kcmil

KVS26
KVS28
KVS31
KVS34
KVS40
KVS44

Tap
6 Str. - 2/0 Str.
10 Str. - 4/0 Str.
10 Str. - 350 kcmil
10 Str. - 500 kcmil
3/0 Str. - 800 kcmil
3/0 Str. - 1000 kcmil

Sol.
3/0
4/0
—
—
—
—

▲
Recommended
Tightening
Torque (in-lb)

Type V
—
V3/0
V250
V350
—
—

180
250
325
375
500
500

▲ Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor combinations.
See note LIGHTNING PROTECTION INFO.

TYPE KVSU

UNIVERSAL OKLIP™
Mechanical Connector All
Combinations of Copper, Aluminum,
ACSR, AAAC & 5005
Compact, high strength, tin plated copper alloy twopiece connector with spacer and tin-plated silicon
bronze DURIUM™ hardware. Recommended
for heavy duty connections. Spacer separates

dissimilar conductors and provides long contact
length. Neoprene ring prevents loss of shorter
bolt during installation. Longer peened bolt

permits swivel action for easier installation. Use
of PENETROX™ joint compound recommended
with aluminum and ACSR.

Conductor

Catalog
Number

Run

Tap

Run

Tap
Steel
Nom.
Dia.

J

L

W

Rec.
Tightening
Torque
(in-lb)

Copper &
Alum

ACSR,
AAAC, &
5005

Copper & Alum

ACSR,
AAAC,
& 5005

KVSU26

2 Str. - 2/0 Str.

3 - 2/0

6 Str. - 2/0 Str.

6 - 2/0

1 - 3/0

5/16 7/16

#6 - 3/0

3/16 7/16

2

5/16

1

1-1/2

180

KVSU28

1/0 Str. - 4/0 Str.

1/0 - 4/0

6 Str. - 4/0 Str.

6 - 4/0

2/0 - 4/0

3/8 - 1/2

#6 - 4/0

5/32 - 1/2

2-3/8

3/8

1-1/8

1-3/4

250

KVSU31

250 - 350 kcmil

4/0 - 300

#6 - 350

6 - 300

-

9/16 - 5/8

#6 - 4/0

3/16 - 5/8

2-5/8

1/2

1-3/8

2-1/8

325

KVSU34

400 - 500 kcmil

336.4 - 397.5

#4 - 500

5 - 397.5

-

3/4 - 3/4

#4 - 4/0

7/32 - 3/4

3

1/2

1-1/2

2-1/4

375

KVSU40

400 - 800 kcmil

4/0 - 800

4/0 - 800

3/0 - 715.5

-

3/4 - 1

-

1/2 - 1

3-1/2

1/2

1-5/8

2-1/2

500

KVSU44

500 - 1000
kcmil

4/0 - 1000

4/0 - 1000 kcmil

4/0 - 900

-

7/8 - 1
1/8

-

1/2 - 1
1/8

4

3/8

2

3

500

Accomodates compressed conductors within diameter range.

Steel
Nom.
Dia.

Copper
Sol.,
Copperweld Sol.

H

Copper
Sol.,
Copperweld
Sol.

See note LIGHTNING PROTECTION INFO.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE KVSW

A-7

OKLIP™
Mechanical Connector
For Copper and Copperweld
Similiar to OKLIP™ Type KVS except for a high
copper alloy spacer that separates run and tap
conductors. Provides high contact pressure,
confines conductor strands, and assures vibrationproof connection. Longer peened bolt, permits
swivel action for easier installation. Silicon bronze
DURIUM™ hardware.
Catalog
Number
KVSW26
KVSW28
KVSW31
KVSW34
KVSW40
KVSW44

Conductor

Run
2 Str. - 2/0 Str.
1/0 Str. - 4/0 Str.
250 - 350 kcmil
400 - 500 kcmil
400 - 800 kcmil
500 - 1000 kcmil

Recommended Tightening
Torque (in-lb)
180
250
325
375
500
500

Tap
6 Sol. - 2/0 Str.
6 Sol. - 4/0 Str.
4 Sol. - 350 kcmil
4 Str. - 500 kcmil
AWG 4/0 - 800 kcmil
250 - 1000 kcmil

See note LIGHTNING PROTECTION INFO.

TYPE KVS-A
ALUMINUM OKLIP™
For Use On All Combinations of
Copper, Aluminum†, ACSR†, AAAC
and 5005
Three-piece, high-conductivity, non-copper
bearing aluminum alloy connector with thick spacer
and aluminum hardware. Hardware in KVS26A
and KVS28A is stainless steel. Recommended for
heavy duty dissimilar metal applications. Spacer
separates conductors and provides long contact

length. Belled entrances prevent chafing, permit
easier assembly of conductors. Longer peened
bolt permits swivel action for easier installation.
Neoprene ring prevents loss of shorter bolt.
PENETROX™ joint compound recommended
with aluminum and ACSR.

Run
Copper,
& Alum.†

ACSR†,
AAAC, & 5005

Tap
Copper,
& Alum.†

ACSR†,
AAAC & 5005

#4 - 2/0
10 Str. - 2/0 Str.
#6 - 2/0
KVS26A 2 Str. - 2/ 0 Str.
1/0 - 4/0
10 Str. - 4/0 Str.
#6 - 4/0
KVS28A 1/0 Str. - 4/0 Str.
250 - 350
4/0 - 336.4
6 Str. - 350 kcmil
#6 - 336.4 kcmil
KVS31A
400 - 500
336.4 - 397.5
4 Str. - 500 kcmil
#5 -397.5 kcmil
KVS34A
400 - 800
336.4 - 715.5 kcmil 3/0 Str. - 800 kcmil
#3/0 - 715.5
KVS40A
500 - 1000
397.5 - 900 kcmil 3/0 Str. - 1000 kcmil #3/0 - 900 kcmil
KVS44A
† Accommodates compressed conductors within diameter range.

APPLICATION OVER ARMOR ROD

Conductor Range by
Diameter

Conductor
Catalog
Number

THESE CONNECTORS CAN ACCOMMODATE
ACSR CONDUCTORS OVER ARMOR ROD
WITHIN THE DIAMETER RANGE INDICATED.

Rec.
Tightening
Torque (in-lb)

Min.
Run
Dia.

Min.
Tap
Dia.

Max.
Run &
Tap Dia.

H

J

L

W

180

0.28

0.12

0.45

2-1/4

5/16

1-1/4

1-5/8

1-5/8

2-1/16

240

0.36

0.12

0.56

3

3/8

300

0.57

0.18

0.68

3-1/16

1/2

1-15/16 2-7/16

300

0.73

0.22

0.81

3-9/16

1/2

2-5/16

2-5/8

300

0.73

0.47

1.04

4-1/16

1/2

2-7/16

2-7/8

480

0.80

0.47

1.16

4-7/8

5/8

2-1/2

3-1/8

See note LIGHTNING PROTECTION INFO.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-8

BURNDY®

TYPE QPX
VERSITAP™
Parallel Clamp For Copper,
Copperweld, Copperweld-Copper
The VERSITAP™ Type QPX is
recommended for Tee, Cross, Parallel,
Butt and Tap connections. Rangetaking, only 10 connectors required to
accommodate conductor sizes from #6
Str. to 1000 kcmil. Edges are rounded
for easy taping. Made of high strength,
high-conductivity copper alloy and silicon
bronze DURIUM™ hardware.

* For various configurations, see page
TYPE QPX-Y

Fig. 1

Fig. 2

Copper Conductor

Dimensions

Catalog
Number

Run

Tap

QPX2C2C

6 Str. - 2 Str.

6 Str. - 2 Str.

1-1/2

QPX282C

1 Str. - 4/0 Str.

6 Str. - 2 Str.

2-1/16

QPX2828

1 Str. - 4/0 Str.

1 Str. - 4/0 Str.

QPX342C

250 - 500 kcmil

6 Str. - 2 Str.

QPX3428

250 - 500 kcmil

1 Str. - 4/0 Str.

QPX3434

250 - 500 kcmil 250 - 500 kcmil

QPX442C
QPX4428
QPX4434
QPX4444

500 - 1000
kcmil
500 - 1000
kcmil
500 - 1000
kcmil
500 - 1000
kcmil

6 Str. - 2 Str.
1 Str. - 4/0 Str.
250 - 500 kcmil
500 - 1000
kcmil

Fig.
No.

1

H

2-3/8
2-3/4

2
1

2

3

J

L

5/16

1-5/16

3/8

1-13/16 1-13/16

5/16
3/8

2-11/16 5/16
2-7/8
3-1/16
3-7/16

▲ Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
conductor combinations.

1-3/8
1-9/16

150

5 Sol. - 3 #7

8A - 4A

250

7 #9 - 7 #5

3A - 3/0V

5 Sol. - 3 #7

8A - 4A

7 #9 - 7 #5

3A - 3/0V

5 Sol. - 3 #7

8A - 4A

7 #9 - 7 #5

3A - 3/0 V

1-3/8

1-7/8

1-3/4

2-1/16

2-1/16

2-3/16

19 #19 - 19 #6

4/0 EK

1-3/8

2-1/4

5 Sol. - 3 #7

8A - 4A

7 #9 - 7 #5

3A - 3/0V

19 #19 - 19 #6

4/0 EK

19 #6

—

1-13/16
3/8

W

Conductor
Rec.
Tightening
Run
Tap
Torque
Copperweld
Copperweld
in-lb ▲ Copperweld
Copperweld
- Copper
- Copper

2-1/16
2-5/8

2-7/16

375

19 #19 - 19 #6

500

19 #6

2-9/16

4/0 EK

—

See note LIGHTNING PROTECTION INFO.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE QPX-Y

A-9

UNIVERSAL VERSITAP™
Universal Parallel Clamp For Copper
and Aluminum
High copper alloy cast connector, tin-plated for use
with copper or aluminum cable. Makes parallel,
tap, tee, cross or end-to-end connections. Edges
rounded for easy taping. PENETROX™ joint
compound recommended.

Fig. 1
Catalog
Number
QPX2C2C-Y

Fig. 2

H

J

L

W

Recommended
Tightening
Torque in-lb ▲
150

Run

Tap

Fig.
No.

6 Str.-2 Str.

6 Str.-2 Str.

1

1-5/8

5/16

1-1/2

1-5/8

QPX282C-Y

1 Str. - 4/0 Str.

6 Str.-2 Str.

1

1-7/8

5/16

1-1/2

1-7/8

150

QPX2828-Y

1 Str. - 4/0 Str.

1 Str. - 4/0 Str.

1

2

3/8

2

2-1/8

250

QPX342C-Y

250 - 500 kcmil

6 Str.-2 Str.

1

2-1/4

5/16

1-1/2

2-1/8

375

QPX3428-Y

250 - 500 kcmil

1 Str. - 4/0 Str.

1

2-1/2

3/8

2

2-1/2

375

QPX3434-Y

250 - 500 kcmil

200 - 500 kcmil

2

2-7/8

3/8

2-1/2

2-5/8

375

QPX4444-Y

750 - 1000 kcmil

750 - 1000 kcmil

2

3-7/8

1/2

3-1/2

3-1/2

500

▲ Listed torque values are for maximum conductor
combinations accommodated. Consult UL486 Tables
7-4, 7-5 7-6 for smaller conductor combinations.

See note LIGHTNING PROTECTION INFO.

APPLICATION
VARIATIONS
PARALLEL

TAP

CROSS

TEE

SPLICE

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-10

BURNDY®

TYPE KPA
SCRULUG™
For Copper Cable
High copper alloy tin-plated terminal for joining
a wide range of cable to equipment pads or
terminal blocks. Especially good in light industrial
applications. The tongue and body are a one-piece
design. The pressure bar equalizes pressure over
the conductor and prevents the screw from cutting
into the cable.
Fig. 1
Wire Range

Fig.
No.

C

KPA8C

14 Sol. - 8 Str.

1

0.38

0.47

KPA4C

14 Sol. - 4 Str.

1

0.50

0.59

KPA25

4 Str. - 1/0 Str.

2

0.75

0.81

KPA28

1/0 Str. - 4/0 Str.

2

0.97

1.12

KPA34

4/0 Str. - 500 kcmil

2

1.38

1.38

Catalog
Number

Fig. 2
K

Stud
Hole Size

0.72

0.21

0.94

0.27

1.25

0.33

5/16

1.66

0.39

3/8

2.44

0.54

1/2

3.32

D

H

Recommended
Tightening
Torque (in-lb)

L

N

T

#10

0.97

0.22

0.06

25

1/4

1.22

0.30

0.06

35

1.82

0.41

0.10

180

2.40

0.53

0.13

250

0.75

0.20

375

NOTE: For unplated version add “UNPL” suffix.

TYPE KPA-UP
SCRULUG™
For Copper Cable
High copper alloy terminal for joining a wide range
of cable to equipment pads or terminal blocks.
Plain copper finish.

Fig. 1

Features & Benefits

• High conductivity copper alloy.
◊ Long lasting, reliable contact.
• Compact design.
◊ Easy to use.
• Slot Robertson screw, hex head, hex
socket bolt.
◊ No special installation tools required.
Eliminates over-torquing/potential
conductor damage.

• One piece design.
◊ Superior torque and pull out
performance.
• Convenient range taking design.
◊ Reduces catalog numbers. One
catalog number accommodates several
conductor sizes.

Catalog
Number

Wire Range

KPA8CUP

14 Sol. - 6 Str.

KPA4CUP

14 Sol. - 4 Str.

Fig.
No.
1

C

D

H

K

Stud Hole
Size

0.38

0.56

0.81

0.20

#10

1.04

0.22

0.50

0.71

1.00

0.28

1/4

1.28

0.33

NOTE: For tin plating drop “-UP” suffix and add “-TP” suffix
(example: KPA4CTP).

L

N

T
0.07

Hardware

Recommended
Tightening
Torque (in-lb)

# 12-24 SLOT

35

5/16 DIA.SLOT
ROBERTSON

45

For use in grounding applications with a green screw, contact
factory. Listed for grounding per UL467.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE KLU

A-11

SCRULUG™
FOR COPPER CABLE OFFSET TONGUE - NON-PLATED
High copper alloy terminal with offset tongue for
joining a wide range of cable to equipment pads
or bar. Easy to install with screwdriver or wrench.
Connector is reusable. Plain copper finish.

Features & Benefits
• Convenient range-taking design.
◊ Reduces catalog numbers.
One conductor accommodates several
conductor sizes.
• High conductivity copper alloy
◊ Long lasting reliable contact.

1

Catalog
Number
KLU25
KLU25TP
KLU35
KLU35TP
KLU70
KLU70TP
KLU125
KLU125TP
KLU175
KLU175TP
KLU225
KLU225TP
KLU300
KLU300TP
KLU400
KLU400TP

• Compact design
◊ Easy to use. Reduces labor time.
• Slot Robertson screw, hex head/hex
socket bolt
◊ No special installation tools required.
eliminates over-torquing/potential
conductor damage.

Rec.
Tightening
Torque
(in-lb)

Stud
Hole
Size

Strip
Length
(in)

No. 8-32 Slotted Round
Machine Screw

#6

7/16

35

1/4 UNF Slotted Set
Screw

#10

5/8

2.00
0.08

40

5/16 UNF Slotted Set
Screw

1/4

3/4

11.0
0.42

3.00
0.11

50

3/8 UNF Slotted Set
Screw

1/4

15/16

56.0
2.20

11.0
0.43

4.00
0.16

250

3/8 UNF Socket/Hex
Screw

3/8

1

9.00
0.34

65.0
2.55

13.0
0.51

3.00
0.12

250

7/16 UNF Socket/Hex
Screw

5/16

1-5/16

25.0
0.99

10.0
0.39

72.0
2.83

13.0
0.52

3.00
0.12

325

5/8 UNF Socket/Hex
Screw

3/8

1-5/8

38.0
1.50

10.0
0.39

104.0
4.09

23.0
0.91

5.00
0.18

375

5/8 UNF Socket/Hex
Screw

3/8

1-5/32

Fig.
No.

B
(MM/IN)

C
(MM/IN)

K
(MM/IN)

L
(MM/IN)

N
(MM/IN)

T
(MM/IN)

14 Sol. .064 Dia.to
10 Sol. .102 Dia. CU

3

7.00
0.28

8.00
0.31

4.00
0.14

26.0
1.02

5.00
0.21

2.00
0.07

20

14 Sol. .0641 Dia.to
6 Str. .184 Dia. CU

2

11.0
0.43

10.0
0.39

5.00
0.20

31.0
1.24

6.00
0.22

2.00
0.07

8 Sol. .129 Dia. to
2 Str. .292 Dia. CU

2

13.0
0.50

12.0
0.47

7.00
0.26

39.0
1.55

6.00
0.25

2 Str. .292 Dia. to
1/0 Str. .372 Dia. CU

2

15.0
0.61

16.0
0.62

7.00
0.26

50.0
1.98

4 Str. .232 Dia. to
3/0 Str. .470 Dia. CU

1

18.0
0.72

19.0
0.75

10.0
0.39

2 Str. .292 Dia. to
4/0 Str. .528 Dia. CU

1

24.0
0.94

25.0
0.99

1/0 Str. .372 Dia. to
350 kcmil .681 Dia. CU

1

31.0
1.22

1/0 Str. .372 Dia. to
500 kcmil .813 Dia. CU

1

36.0
1.42

Conductor

Hardware

NOTES:
1 Suffix “-TP” on catalog number denotes tin plate (example: KLU400TP).

2 Material: Copper alloy.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-12

BURNDY®

TYPE KA
KA-LUG™
For Copper Cable
Compact, economical, high copper alloy terminal
for joining a wide range of cable to equipment pads
or terminal blocks.

Fig. 1

Catalog
Number

Conductor

KA4C
KA25
KA25-2TC38
KA28
KA34

Fig. 3

Fig.
No.

C

H

J

K

Stud
Hole
Size

L

N

T

Recommended
Tightening
Torque (in-lb)

1

3/8

5/8

#12

7/32

#10

13/16

3/16

3/32

25

1

9/16

3/4

5/16"

9/32

1/4

1-1/8

1/4

7/64

45

2

3/4

15/16

1/2"

27/64

3/8

1-11/16

3/8

1/8

200

3

3/4

15/16

1/2"

27/64

3/8

2-13/16

3/8

1/8

200

2

15/16

1-1/4

5/8"

27/64

3/8

1-15/16

7/16

3/16

275

2

1-3/8

2-3/32

13 /16"

9/16

1/2

2-9/16

9/16

9/32

375

# 14 Sol. (0.064 Dia.) 8 Str. (0.416 Dia.)
# 14 Sol. (0.064 Dia.) 4 Str. (0.232 Dia.)
# 4 Str. (0.232 Dia.) 1/0 Str. (0.373 Dia.)
# 4 Str. (0.232 Dia.) 1/0 Str. (0.373 Dia.)
# 1 Str. (0.332 Dia.) 4/0 Str. (0.528 Dia.)
4/0 Str. (0.528 Dia.) 500 kcmil (0.814 Dia.)

KA8C

Fig. 2

▲ Listed torque values are for maximum conductor sizes
accommodated.

Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes.

TYPE EA
VERSILUG™
For Copper Cable
Compact, high copper alloy terminal for joining
a wide range of cable to equipment pads or bar.
Clamping element adjustable to several angles.
One-wrench installation.
Catalog
Number

Wire Range

EA2C
EA25
EA28
EA28-2N
EA34
EA34-2N

8 AWG-2 AWG
2 AWG-1/0
1/0 -4/0 AWG
1/0 -4/0 AWG
250 kcmil-500 kcmil
250 kcmil-500 kcmil

No. of
holes in
pad
1
1
1
2
1
2

* “N” indicates NEMA standard stud holes.
▲ Listed torque values are for maximum conductor sizes
accommodated.

C

D

E

H

K

13/16
7/8
1-1/16
1-1/16
1-3/8
1-3/8

1-1/16
1-1/8
1-3/8
3-5/8
1-5/8
3-5/8

—
—
—
1-3/4
—
1-3/4

1-3/8
1-7/16
1-3/4
1-3/4
2-1/4
2-1/4

7/16
7/16
7/16
9/16
9/16
9/16

Stud
Hole
Size
3/8
3/8
3/8
1/2
1/2
1/2

L

N

T

2-1/2
2-11/16
3-3/16
5-1/8
4
5-5/8

13/32
7/16
17/32
5/8
13/16
5/8

1/4
1/4
5/16
5/16
3/8
3/8

Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes.

Rec.
Tightening
Torque (in-lb)
150
180
250
250
375
375

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE BGBL

A-13

LAY-IN QIKLUG™
UL LISTED 90° C, 600 V
The Lay-In QIKLUG™, Type BGBL is
manufactured from high strength 6061-T6
aluminum, and is ideally suited for grounding and
bonding applications accommodating both copper
and aluminum conductor sizes #14 AWG to 250
kcmil. The BGBL4SS with Stainless Steel screw is
UL 467 Listed for grounding and bonding.

H
REF
N

Features & Benefits

T

• UL 486B listed, AL9CU rated
◊ For copper and aluminum conductor
combinations up to 90° C, 600 Volt
applications.
• UL Recognized for grounding and
bonding
◊ Ensures reliability.
• Electro-tin plated
◊ Provides low contact resistance.
• Lay-in feature
◊ Eases installation.

L

C

K DIA.

J

Conductor Range

C

H

J

K

L

N

T

Hex
Size

BGBL-4

14 - 4

0.38
[10]

0.78
[20]

1/4 - 28

0.22
[6]

1.07
[27]

0.19
[5]

0.15
[4]

Slot

BGBL4SS*

14 - 4

0.38
[10]

0.78
[20]

1/4 - 28

0.22
[6]

1.07
[27]

0.19
[5]

0.15
[4]

Slot

BGBL-1/0

14 - 1/0

0.60
[15]

1.17
[30]

3/8 - 24

0.27
[7]

1.50
[38]

0.30
[8]

0.22
[6]

Slot

BGBL-250

6 - 250
kcmil

0.80
[20]

1.79
[45]

9/16 - 18

0.33
[8]

2.20
[56]

0.40
[10]

0.30
[8]

5/16

Catalog
Number

* Suitable for copper conductors only.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-14

BURNDY®

TYPE CL50-1 & CL50-1TN
COPPER LAY-IN QIKLUG™
For Copper
The Lay-In QIKLUG™ is manufactured from
high strength pure electrolytic copper to ensure
maximum strength and conductivity. UL467
Listed for direct burial in earth or concrete. The
open-faced design allows for fast lay-in of the
conductor without the need for cutting or breaking.
Stainless steel screws used for excellent corrosion
resistance.

Catalog
Number

Conductor
Range

Stud
Hole

CL50-1

14 AWG-4 AWG

#10

CL50-1TN

14 AWG-4 AWG

#10

Photo above shows a typical solar panel installation using CL50-1 connectors.

TYPE CL
COPPER LAY-IN QIKLUG™
For Copper
Manufactured for maximum strength and
conductivity, these lay-in lugs allow for continuous
runs of conductor and are well suited as
terminations as well. Tin-plated, set screw style
connectors, three sizes cover a range from
#14AWG to 250 kcmil. CL3/0-516TN and CL250516TN are UL Listed and CSA certified. CL1/014TN UL Listed for grounding and CSA certified.
90° C rated. Suitable for copper conductors only.

Catalog
Number

Wire Range
Copper

H

W

L

T

K
Dia

Hex Size

CL1/0-14TN

#14 - 1/0 AWG

1.17

0.60

1.50

0.22

0.27

7/16-20 (Slotted)

CL3/0-516TN

#6 - 3/0 AWG

1.56

0.80

2.00

0.30

0.33

9/16-18 (0.25 Hex)

CL250-516TN

#6 AWG - 250 kcmil

1.79

0.80

2.20

0.30

0.33

9/16-18 (0.25 Hex)

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPES QA, QQA

A-15

QIKLUG™
Copper Cable
Type QA heavy duty, compact, high copper
alloy terminal for joining a wide range of cable
to equipment pads or bar. Fast one-wrench
installation. Type QQA heavy duty, high copper
alloy terminal for joining cable to equipment
pads or bar. Twin clamping elements secure joint
vibration and flexing. One-wrench installation.

Type QA

Catalog Number*
Type QA
QA8C-B
QA8C-2B
QA4C-B
QA4C-2B
QA1C-B
QA1C-2B
QA26-B
QA26-2B
QA28-B
QA28-2B
QA28-2N*
QA31-B
QA31-2B
QA31-2N
QA34-B
QA34-2B
QA34-4B
QA34-2N*
QA40-B
QA40-2N*
QQA40-4N*
QA44-B
QA44-2N*
QA44-4N*
QA46-2N*
QA46-B

Type QQA

Conductor
Commercial

14 Sol. - 8 Str.
QQA8C
14 Sol. - 8 Str.
QQA8C-2
8 Str. - 4 Str.
QQA4C
8 Str. - 4 Str.
QQA4C-2
4 Str. - 1 Str.
QQA1C
4 Str. - 1 Str.
QQA1C-2
1/0
Str. - 2/0 Str.
QQA26
1/0 Str. - 2/0 Str.
QQA26-2
3/0 Str. - 4/0 Str.
QQA28
3/0 Str. - 4/0 Str.
—
QQA28-2N* 3/0 Str. - 4/0 Str.
250 - 350 kcmil
QQA31
250 - 350 kcmil
—
QQA31-2N* 250 - 350 kcmil
400 - 500 kcmil
—
400 - 500 kcmil
—
400 - 500 kcmil
QQA34
QQA34-2N* 400 - 500 kcmil
600 - 800 kcmi
—
QQA40-2N* 600 - 800 kcmi
600 - 800 kcmi
—
850 - 1000 kcmil
—
QQA44-2N* 850 - 1000 kcmil
QQA44-4N* 850 - 1000 kcmil
1100 - 1500 kcmil
—
1100 - 1500 kcmil
—

Type QQA

Navy

Holes
in Pad

C

D

E&F

H

K

Stud
Hole
Size

L

LL

N

T

Torque
(in-lb)

4-14

1

9/16

9/16

—

11/16

7/32

#10

1-3/8

2-5/16

9/32

5/32

75

4-14

2

9/16

1-1/14

5/8

11/16

7/32

#10

2

3

5/16

5/32

75

23-40

1

5/8

5/8

—

3/4

9/32

1/4

1-7/16

2-3/8

5/16

3/16

110

23-40

2

5/8

1-3/16

5/8

3/4

9/32

1/4

2

2-15/16

5/16

3/16

110

50-75

1

5/8

3/4

—

1

9/32

1/4

1-3/4

2-13/16

11/32

7/32

150

50-75

2

5/8

1-9/16

7/8

1

11/32

5/16

2-9/16

3-5/8

11/32

7/32

150

100-125

1

13/16

1

—

1-3/16

13/32

3/8

2

3-3/16

7/16

7/32

180

100-125

2

13/16

1-15/16

1

1-3/16

13/32

3/8

3

4-3/16

7/16

7/32

180

150-200

1

1

1-1/16

—

1-5/16

13/32

3/8

2-1/4

3-9/16

17/32

1/4

250

—

2

1

2

1

1-9/29

13/32

3/8

3-1/5

—

7/16

1/4

250

150-200

2

1

3-1/8

1-3/4

1-5/16

9/16

1/2

4-5/16

5-5/8

5/8

1/4

250

250-350

1

1-3/16

1-3/8

—

1-11/16

17/32

1/2

2-11/36

4-1/8

11/16

5/16

325

250-350

2

1-3/16

1-31/32

1

1-11/16

7/16

3/8

3-3/8

—

7/16

5/16

325

5/8

5/16

325

250-350

2

1-3/16

3

1-3/4

1-11/16

9/16

1/2

4-7/16

5-7/8

400-500

1

1-3/8

1-5/8

—

2

17/32

1/2

3-3/16

4-7/8

400-500

2

1-3/8

2

1

2

13/32

3/8

3-9/16

400-500

4

1-7/8

1-15/16

1

2

7/16

3/8

400-500

2

1-3/8

3-3/32

1-3/4

2

9/16

1/2

650-800

1

1-5/8

1-7/8

—

2-7/16

11/16

5/8

650-800

2

1-5/8

3

1-3/4

2-7/16

9/16

650-800

4

3

3

1-3/4

2-7/16

9/16

1000

1

1-7/8

2

—

2-3/4

1000

2

1-7/8

3

1-3/4

2-3/4

13/16 5/16

375

—

7/16

375

3-1/2

—

7/16

5/16

375

4-11/16

6-9/32

5/8

5/16

375

3-11/16

—

27/32

3/8

500

1/2

4-14/16

7-3/32

5/8

3/8

500

1/2

—

7-3/32

5/8

3/8

500

11/16

5/8

3-15/16

—

1

1/2

500

9/16

1/2

5

7-1/8

5/8

1/2

500

5/16

1000

4

3

3-1/16

1-3/4

2-3/4

9/16

1/2

5

7-1/8

5/8

1/2

500

1300

2

2-1/8

3

1-3/4

3-1/8

9/16

1/2

5-1/4

—

5/8

9/16

600

1300

1

2-1/8

2-1/8

—

3-1/8

13/16

3/4

4-3/8

—

1-1/16 9/16

600

* ‘‘N’’ indicates NEMA standard stud holes.

All 4N items see note LIGHTNING PROTECTION INFO.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-16

BURNDY®

TYPE Q2A
QIKLUG™
For Copper Cable
Compact, high copper alloy terminal for joining two
cables to equipment pads or bars. Each element
accommodates a wide range of cable. Onewrench installation.

Catalog
Number*
Q2A1C-2
Q2A26-2N
Q2A28-2N
Q2A28-4N
Q2A31-2N
Q2A31-4N
Q2A34-2N
Q2A34-4N
Q2A40-2N
Q2A40-4N
Q2A44-4N
Q2A46-4N

Conductor
4 Str. - 1 Str.
1/0 Str. - 2/0 Str.
3/0 Str. - 4/0 Str.
250 - 350 kcmil
400 - 500 kcmil
600 - 800 kcmil
850 - 1000 kcmil
1100 - 1500 kcmil

No. of
Holes in
Pad
2
4
2
4
2
4
2
4

C

D

E&F

H

K

1-1/2
1-5/8
1-7/8
3
2-3/8
3
2-1/2

1-7/8

1
3/4

1-1/16
1-3/16

7/16

Stud
Hole
Size
3/8

1-3/8

N

2-7/8
4-3/16
4-3/8

7/16

1-3/4

3
3-1/4
3-1/2 3-1/4

9/16

2

T

1/2

W
1-13/16

7/32

1-15/16

1/4

4-1/2

1-11/16

3-1/8

* ‘‘N’’ indicates NEMA standard stud holes.

L

2-1/8

5/16
5/8

4-11/16

3

3/8

3-3/4

2-7/16

5

7/16

2-3/4
3-1/8

5-1/4
5-1/2

1/2
11/16

4-11/32
5

Recommended
Tightening
Torque in-lb
150
180
250
325
375
500
600

All 4N items see note LIGHTNING PROTECTION INFO.

TYPE Q3A
QIKLUG™
For Copper Cable
Compact, high copper alloy terminal for joining
three cables to equipment pads or bar. Each
element accommodates a wide range of cable.
One-wrench installation.
Catalog
Number*
Q3A28-2N
Q3A28-4N
Q3A31-2N
Q3A31-4N
Q3A34-2N
Q3A34-4N
Q3A40-4N
Q3A44-4N
Q3A46-4N

Conductor
3/0 Str. - 4/0 Str.
3/0 - 4/0 Str.
250 - 350 kcmil
400 - 500 kcmil
600 - 800 kcmil
850 - 1000 kcmil
1100 - 1500 kcmil

No. of
Holes in
Pad
2
4
2
4
2
4

C
1-7/8
3
2-3/8
3
2-1/2

D

3-1/8

3
3-1/4
3-1/2 3-1/4

E&F

1-3/4

H

K

Stud
Hole
Size

L

N

T

W

Recommended
Tightening
Torque in lb

1-3/8

4-5/16
4-3/8

1/4

3-3/16

250

1-11/16

4-7/16

5/16

4-1/16

325

3/8

4-9/16

375

7/16
1/2
11/16

5-13/16
6-5/8
7-7/8

1-15/16

9/16

1/2

2-7/16
2-3/4
3-1/8

4-3/4
5
5-1/4
5-1/2

5/8

500
600

* ‘‘N’’ indicates NEMA standard stud holes.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE QB

A-17

QIKLUG™
For Copper Cable
Compact, high copper alloy side entrance terminal
for joining a range of cable at right angles to
terminal blocks. One-wrench installation.

Catalog
Number*

Conductor

No. of
Holes in
Pad

C

D

E

H

K

Stud
Hole
Size

L

N

T

Recommended
Tightening
Torque in-lb

QB8C

14 Sol. - 8 Str.

1

9/16

9/16

—

7/8

7/32

#10

1-1/8

9/32

5/32

75

QB4C

8 Str. - 4 Str.

1

11/16

27/32

—

13/16

9/32

1/4

1-3/8

11/32

1/4

110

QB1C

4 Str. - 1 Str.

1

11/16

13/16

—

1

9/32

1/4

1-1/2

11/32

7/32

150

QB26

1/0 Str. - 2/0 Str.

1

13/16

1

—

1-1/32

13/32

3/8

1-13/16

7/16

7/32

180

QB28

3/0 Str. - 4/0 Str.

1

1

1-1/16

—

1-5/16

13/32

3/8

2-1/16

17/32

1/4

250

QB31-2N

250 - 350 kcmil

2

13/16

3-1/4

1-3/4

1-11/16

9/16

1/2

4-1/2

5/8

5/16

325

* ‘‘N’’ indicates NEMA standard stud holes.

TYPE Q2B
QIKLUG™
For Copper Cable
Compact, high copper alloy terminal for joining two
cables at right angles to a single terminal block.
Each element accommodates a range of cable.
One-wrench installation.

No. of
Holes in
Pad

Stud
Hole
Size

L

9/16

1/2

5-3/16

9/16

9/16

5-7/8

3/4

6-11/16

5/8

Catalog
Number*

Conductor

Q2B28-2N

3/0 Str. - 4/0 Str.

2

1-7/8

3-1/8

1-3/4

1-3/8

Q2B31-2N

250 - 350 kcmil

2

2-3/8

3-3/16

1-11/16

1-3/8

Q2B40-4N

600 - 800 kcmil

4

3

3-1/16

1-3/8

2-5/16

9/16

C

D

* ‘‘N’’ indicates NEMA standard stud holes.

E& F

H

K

T

Recommended
Tightening
Torque in-lb

5/8

1/4

250

5/8

5/16

325

7/16

500

N

All 4N items see note LIGHTNING PROTECTION INFO.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-18

BURNDY®

TYPE QDA
QIKLUG™
For Copper Cable
Compact, high copper alloy terminal for joining a
wide range of cable to equipment studs. Provides
low contact resistance when gripped between two
contact nuts. One wrench installation.

Conductor

C

H

K

Stud
Hole
Size

L

T

Recommended
Tightening
Torque in-lb

3 - 14

1

11/16

7/16

3/8

1-7/8

3/16

75

8 Str. - 4 Str.

23 - 40

1

3/4

7/16

3/8

1-7/8

7/32

110

4 Str. - 1 Str.

50 - 75

1

1

7/16

3/8

2-3/16

9/32

150

QDA26

1/0 Str. - 2/0 Str.

100 - 125

1-1/4

1-3/16

9/16

1/2

2-1/2

5/16

180

QDA28

3/0 Str. - 4/0 Str.

150 - 200

1-1/4

1-5/16

9/16

1/2

2-5/8

5/16

250

QDA31

250 - 350 kcmil

250 - 350

1-1/2

1-11/16

11/16

5/8

3

5/16

325

QDA34

400 - 500 kcmil

400 - 500

1-7/8

2

13/16

3/4

3-5/8

5/16

375

QDA40

600 - 800 kcmil

650 - 800

2-1/8

2-5/16

1-1/16

1

4-3/16

3/8

500

Catalog
Number

Commercial

Navy

QDA8C

14 Sol. - 8 Str.

QDA4C
QDA1C

TYPE QR
QIKLINK™ SPLICE OR REDUCER
For Copper Cable to Cable
High copper alloy splicer/reducer for joining a
range of cable end to end. Neat, compact easy to
tape installation. One-wrench installation.

Catalog Number

Conductor
Either Side

H

L

W

Recommended
Tightening
Torque in-lb

QR4C

6 Sol. - 4 Str.

3/4

1-11/16

5/8

110

QR1C

4 Str. - 1 Str.

1-1/16

1-15/16

11/16

150

QR26

1/0 Str. - 2/0 Str.

1-3/16

2-1/8

13/16

180

QR28

3/0 Str. - 4/0 Str.

1-3/8

2-3/8

1

250

QR31

250 - 350 kcmil

1-11/16

2-5/8

1-1/4

325

QR34

400 - 500 kcmil

1-15/16

3-1/16

1-7/16

375

QR40

600 - 800 kcmil

2-7/16

3-5/8

1-7/8

500

See note LIGHTNING PROTECTION INFO.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE VT

A-19

VARITAP™ T-CONNECTOR
For Copper Cable to Cable
High copper alloy T-connector for cable run, cable
tap. V-bolt clamping elements accommodate large
range of cable and are particularly suited for extra
flexible cable. One-wrench installation.

Conductor

Catalog
Number

H

L

W

Recommended
Tightening Torque

Run (A)

Tap (AA)

Run

Tap

VT2C2C

8 AWG-2 AWG

8 AWG-2 AWG

1-5/16

2-5/16

1-5/16

275

275

VT2525

6 AWG-1/0

6 AWG-1/0

1-5/8

2-5/8

1-7/16

385

385

VT2825

1/0 -4/0 AWG

6 AWG-1/0

1-5/8

3-1/8

1-1/4

250

385

VT2828

1/0 -4/0 AWG

1/0 -4/0 AWG

1-5/8

3-1/16

1-11/16

250

250

VT3025

1/0 -300 kcmil

6 AWG-1/0

1-7/8

3-3/8

1-3/8

325

385

VT3030

1/0 -300 kcmil

1/0 -300 kcmil

1-7/8

3-5/16

1-15/16

325

325

VT3425

300 kcmil-500 kcmil

6 AWG-1/0

3-11/32

3-11/16

1-1/2

375

385

VT3428

300 kcmil-500 kcmil

1/0 -4/0 AWG

3-11/32

3-1/2

1-11/16

375

250

VT3430

300 kcmil-500 kcmil

1/0 -300 kcmil

3-11/32

3-5/8

1-15/16

375

325

VT3434

300 kcmil-500 kcmil

300 kcmil-500 kcmil

3-11/32

3-3/4

2-1/4

375

375

VT4040

500 kcmil-800 kcmil

500 kcmil-800 kcmil

2-9/16

4-1/2

2-5/8

500

500

VT4425

750 kcmil-1000 kcmil

6 AWG-1/0

2-7/8

4-5/16

1-3/16

500

385

VT4428

750 kcmil-1000 kcmil

1/0 -4/0 AWG

2-7/8

4-1/8

1-11/16

500

250

VT4834

1500 kcmil-2000 kcmil

300 kcmil-500 kcmil

4-1/4

5-1/4

2-1/4

600

375

See note LIGHTNING PROTECTION INFO.

TYPE E-C-G
TRANSFORMER TAP ADAPTER
For Copper
Multi-tap, range-taking cast copper alloy connector
designed to take 2, 3 or 4 conductors from a single
secondary transformer outlet.

Catalog Number

Number of
Conductors

E2C34G1

2

E3C34G1

3

E4C34G1

4

Conductor
Size

A dia

H

J

L

W

Recommended
Tightening
Torque

3-1/2
1/0 Sol. - 500 kcmil

0.78

2-7/8

1/2"-13

6-1/4

5-1/4

480

6-7/8

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-20

BURNDY®

TYPES VA, VVA
VARILUG™
For Copper Cable
High copper alloy terminal for joining a wide range
of cable to equipment pads or bar. Particularly
suitable for use on extra flexible cable. Onewrench installation. Type VVA, twin elements
secure joint against vibration and flexing.
Particularly recommended for use on extra flexible
cables. One-wrench installation.

Type VA

Catalog Number*
Type VA

Type VVA

VA2C

VVA2C

Type VVA

Conductor

No. of
Holes
in Pad

C

D

E&F

H

K

Stud
Hole
Size

L

LL

N

T

Rec.
Tightening
Torque

8 AWG-2 AWG

1

13/16

1-1/4

—

1-1/2

7/16

3/8

2-3/4

4-1/16

13/32

1/4

275

VA25

VVA25

6 AWG-1/0

1

7/8

1-5/16

—

1-7/8

7/16

3/8

2-7/8

4-5/16

7/16

1/4

385

VA28

VVA28

1/0 -4/0 AWG

1

1-1/16

1-1/2

—

2-1/4

7/16

3/8

2-7/8

4-1/8

17/32

5/16

250

VA28-2N

VVA28-2N

1/0 -4/0 AWG

2

1-1/16

3-1/2

1-3/4

2-1/4

9/16

1/2

4-15/16

6-1/5

5/8

5/16

250

VA30

VVA30

1/0 -300 kcmil

1

1-1/8

1-5/8

—

2-3/16

7/16

3/8

3-1/4

4-5/8

5/8

5/16

325

VA30-2N

VVA30-2N

1/0 -300 kcmil

2

1-1/8

3-9/16

1-3/4

2-3/16

9/16

1/2

5-3/16

6-9/16

5/8

5/16

325

—

VA34

VVA34

300 kcmil-500 kcmil

1

1-3/8

2

3-11/32

9/16

1/2

3-13/16

5-5/16

13/16

3/8

375

VA34-2N

VVA34-2N

300 kcmil-500 kcmil

2

1-3/8

3-5/8

1-3/4 3-11/32

9/16

1/2

5-3/8

6-7/8

5/8

3/8

375

VA34-4N VVA34-4N 300 kcmil-500 kcmil

4

3

3-5/8

1-3/4 3-11/32

9/16

1/2

5-3/8

6-7/8

5/8

3/8

375

VA40

VVA40

500 kcmil-800 kcmil

1

1-5/8

2-5/16

—

2-7/8

11/16

5/8

4-1/2

6-3/8

15/16

3/8

500

VA40-2N

VVA40-2N

500 kcmil-800 kcmil

2

1-5/8

3-5/8

1-3/4

2-7/8

9/16

1/2

5-13/16

7-11/16

5/8

3/8

500

VA40-4N VVA40-4N 500 kcmil-800 kcmil

4

3

2-5/8

1-3/4

2-7/8

9/16

1/2

5-13/16

7-11/16

5/8

3/8

500

* “N” indicates NEMA standard stud holes.

All 4N items see note LIGHTNING PROTECTION INFO.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE HFB-P1

A-21

BAR CLAMP ASSEMBLY
COMPONENTS
For Copper Bar
To build your own high strength clamp assembly
for multiple flat bar using type HFB-P1 bar clamps
and clamping hardware, the following tables have
been provided. The clamp assembly eliminates the
need for drilling the flat bar and is used in indoor
and outdoor applications.

One Clamp Half
Bar Clamp Bar
Tap ‘AA’

“J” Bolt
Dia.

L

W

Z

Recommended
Tightening
Torque in-lb

2

2

3/8

4.38

4.38

*

240

Catalog
Number

Run ‘A’

HFB22P1
HFB33P1

3

3

3/8

4.38

4.38

*

240

HFB42P1

4

2

3/8

5.75

5.75

*

240

HFB44P1

4

4

1/2

5.75

5.75

*

480

HFB63P1

6

3

1/2

7.75

4.75

*

480

HFB66P1

6

6

5/8

8.12

8.12

*

660

HFB88P1

8

8

3/4

10.50

10.50

*

1990

*Z=Space between the bar clamp contact surfaces

Bar Clamp Assembly Components †
Copper Bus Bar Width (in)

Silicon Bronze Clamping Hardware

Bar Clamp

Bolts

Nuts

Split Lock Washers

Run-A

Tap-AA

Qty

Cat. No.

Qty

Cat. No.

Qty

Cat. No.

Qty

Cat. No.

2

2

2

HFB22P1

4

38 X (*) HEB

4

38CHEN

4

38SW

3

3

2

HFB33P1

4

38 X (*) HEB

4

38CHEN

4

38SW

4

2

2

HFB42P1

4

38 X (*) HEB

4

38CHEN

4

38SW

4

4

2

HFB44P1

4

50 X (*) HEB

4

50CHEN

4

50SW

6

3

2

HFB63P1

4

50 X (*) HEB

4

50CHEN

4

50SW

6

6

2

HFB66P1

4

62 X (*) HEB

4

62CHEN

4

62SW

8

8

2

HFB88P1

4

75 X (*) HEB

4

75CHEN

4

75SW

† Ordered separately from BURNDY®.
* See table below when ordering assembly clamping
bolts to specify correct bolt length in Cat. #.

Bolt Length
Clamp
Number

“J”
Bolt Dia.

When
Z = 1.25

When
Z = 1.50

When
Z = 1.75

When
Z = 2.00

When
Z = 2.25

When
Z = 2.50

When
Z = 2.75

When
Z = 3.00

HFB22P1

3/8

3.00

3.25

3.50

4.00

4.00

4.50

4.50

5.00

HFB33P1

3/8

3.00

3.25

3.50

4.00

4.00

4.50

4.50

5.00

HFB42P1

3/8

3.00

3.25

3.50

4.00

4.00

4.50

4.50

5.00

HFB44P1

1/2

3.25

3.50

3.75

4.00

4.50

4.50

5.00

5.00

HFB63P1

1/2

3.25

3.50

3.75

4.00

4.50

4.50

5.00

5.00

HFB66P1

5/8

3.50

4.00

4.00

4.50

4.50

5.00

5.00

5.50

HFB88P1

3/4

3.75

4.00

4.50

4.50

5.00

5.00

5.50

5.50

NOTE: When ordering assembly bolts specify correct bolt
length in catalog number as indicated in table.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-22

BURNDY®

TYPE HFB-N
BAR CLAMP TAP PAD ADAPTER
For Copper Bar
High conductivity copper, tap pad adapter provides
a NEMA drilled contact pad when assembled to the
HFB-P1 clamps. Tap connections can be made
from copper bus bar(s) without drilling, by bolting
standard mechanical or compression terminal
pads directly to the pre-drilled tap pad adapter.

Catalog
Number

Fig. #

A&C

E&F

L

N

Use with ‘H’ Clamp
Catalog Number 1

HFB33-4N

1

3.00

1.75

7.00

0.62

HFB33P1

HFB44-4N

1

4.00

1.75

9.12

1.12

HFB44P1

HFB66-6N

2

6.00

1.75

11.31

1.12

HFB66P1

1 ‘H’ Clamp (two required per assembly) and hardware

(as shown) not included with bar clamp tap pad, order
separately.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPES KA-U, KKA-U

A-23

UNIVERSAL TERMINAL
For Aluminum and Copper
Conductors

Fig. 1

Fig. 2

Fig. 3

Fig. 4

These dual-rated one-conductor lugs are
constructed from high strength aluminum alloy
and electro tin-plated to provide low contact
resistance.

AL9CU

Fig. 5
Catalog
Number*

Fig.
No.

Wire Range
Aluminum or Copper

Stud
Hole
Size

D

L

N

**
W

E

T

**
H

Recommended
Tightening ▲
Torque (in-lb)

KA6U

1

14 AWG-6 AWG

1/4

0.63

1.06

0.25

0.50

—

0.09

0.51

45

KA2U

1

14-2

1/4

0.63

1.16

0.31

0.50

—

0.10

0.56

50

KA25U

1

14 AWG-1/0

1/4

0.81

1.50

0.44

0.63

—

0.19

0.92

50

KA26U

2

6-2/0

1/4

0.81

1.47

0.45

0.63

—

0.19

0.80

120

KA29U

2

6-250

5/16

0.94

2.00

0.47

1.00

—

0.25

1.14

275

KA30U

2

6 AWG-300 kcmil

5/16

0.94

2.00

0.45

1.00

—

0.25

1.14

275

KA31U

2

6 AWG-350 kcmil

3/8

1.03

2.25

0.52

1.13

—

0.25

1.27

275

KA34U

2

4 AWG-500 kcmil

3/8

1.50

2.81

0.88

1.51

—

0.31

1.58

500

KA36U

2

2 AWG-600 kcmil

3/8

1.72

3.19

0.78

1.50

—

0.44

1.58

500

KA40U

2

300 kcmil-800 kcmil

1/2

1.85

3.50

0.81

1.75

—

0.50

1.95

550

KA44U

2

500 kcmil-1000 kcmil

1/2

1.69

3.50

0.88

1.75

—

0.50

1.95

550

KKA31U-2N

3

6 AWG-350 kcmil

1/2

3.16

5.50

0.63

1.25

1.75

0.38

1.52

275

KA36U-2N

4

2 AWG-600 kcmil

1/2

3.22

4.69

0.63

1.50

1.75

0.44

1.57

500

KA40U-2N

4

300 kcmil-800 kcmil

1/2

3.03

4.75

0.63

1.75

1.75

0.50

1.95

500

KA44U-2N

4

500 kcmil-1000 kcmil

1/2

3.03

4.75

0.63

1.75

1.75

0.50

1.95

550

KA30226U

5

2 Str. - 300 kcmil or
(2) 4 Str. - 2/0 Str.

5/16

1.31

2.31

2.00

0.86

–

0.25

1.50

275

KA36229U

5

4 Str. - 600 kcmil or
(2) 250 kcmil - 1/0 Str.

5/8

1.50

2.81

1.00

1.38

–

0.31

1.81

375

KA39229U

5

1/0 Str. - 750 kcmil or
(2) 1/0 Str. - 250 kcmil

1/2

1.50

2.81

1.00

1.38

–

0.31

1.81

375

* “N” indicates NEMA standard stud holes.
▲ Listed torque values are for maximum conductor sizes accommodated.

Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes.
** Maximum dimension.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-24

BURNDY®

TYPES KA-UAR
UNIVERSAL ANTI-ROTATE
TERMINALS
(One Conductor)
For Aluminum and Copper
Conductors
These dual-rated one-conductor lugs are
constructed from high strength aluminum alloy and
electro tin-plated to provide low contact resistance.
These lugs also contain a bottom anti-turn tab.

AL9CU

Wire Range
Aluminum or Copper

Stud
Hole
Size

Depth

Width

Height

Recommended
Tightening ▲
Torque (in-lb)

KA4UAR

14 - 4

1/4

1.16

0.50

0.55

45

KA25UAR

14 - 1/0

1/4

1.47

0.63

0.81

50

KA26UAR

14 - 2/0

1/4

1.47

0.63

0.81

120

KA30UAR

6 - 300

1/4

1.56

0.94

1.13

275

KA31UAR

6 - 350

5/16

1.19

1.00

1.13

275

KA36UAR

4 - 600

3/8

2.75

1.38

1.57

375

Catalog
Number

Listed torque values are for maximum conductor sizes
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for
smaller conductor sizes.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE K2A-U

A-25

UNIVERSAL TERMINAL
(Two Conductor)
For Aluminum and Copper
Conductors

Fig. 1

Fig. 2

These dual-rated two-conductor lugs are
constructed from high strength aluminum alloy and
electro tin-plated to provide low contact resistance.

AL9CU

Fig. 3

Catalog
Number*

Fig.
No.

TWO: Wire Range
(Aluminum or Copper)

Stud
Hole
Size

D

L

N

**
W

E

T

**
H

Recommended
Tightening ▲
Torque (in-lb)

K2A25U

1

14 AWG-1/0

1/4

0.81

1.47

0.44

1.13

—

0.19

0.79

50

K2A26U

2

14 AWG-2/0 AWG

1/4

0.81

1.47

0.44

1.25

—

0.19

0.80

120

K2A29U

2

6 AWG-250 kcmil

3/8

1.50

2.56

0.50

1.66

—

0.25

1.20

275

K2A31U

2

6 AWG-350 kcmil

1/2

1.69

2.88

0.88

1.94

—

0.25

1.26

275

K2A36U

2

2 AWG-600 kcmil

1/2

1.75

3.20

0.63

2.41

—

0.44

1.58

375

K2A40U

2

300 kcmil-800 kcmil

5/8

1.66

3.38

0.88

3.19

—

0.50

1.95

500

K2A44U

2

500 kcmil-1000 kcmil

5/8

1.66

3.50

0.88

3.52

—

0.50

1.95

500

K2A31U-2N

3

6 AWG-350 kcmil

1/2

3.00

4.50

0.63

2.31

1.75

0.31

1.39

275

K2A36U-2N

3

2 AWG-600 kcmil

1/2

3.22

4.69

0.63

2.41

1.75

0.44

1.39

375

K2A40U-2N

3

300 kcmil-800 kcmil

1/2

3.03

4.75

0.63

3.19

1.75

0.50

1.95

375

K2A44U-2N

3

500 kcmil-1000 kcmil

1/2

3.03

4.75

0.63

3.19

1.75

0.50

1.95

375

* “N” indicates NEMA standard stud holes.
▲ Listed torque values are for maximum conductor sizes
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for
smaller conductor sizes.
** Maximum dimension.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-26

BURNDY®

TYPES K3A-U, KK3A-U
UNIVERSAL TERMINAL
(Three Conductor)
For Aluminum and Copper Conductors

Fig. 1

Fig. 2

Dual-rated three-conductor lugs are constructed
from high strength aluminum alloy and electro tinplated to provide low contact resistance.

Fig. 3

AL9CU

Fig. 4

Fig. 5
Catalog
Number**

Fig.
No.

THREE: Wire Range
(Aluminum or Copper)

K

K3A2U-2*
K3A25U-2*
K3A26U-2N
K3A27U-2N
K3A29U-2N
K3A31U-2N
K3A36U-2N
KK3A36U-2N
KK3A40U-2N
KK3A44U-2N
K3A2U-4*
K3A25U-4*
K3A27U-4N
K3A29U-4N
K3A31U-4N
K3A36U-4N
K3A40U-4N
KK3A36U-4N
KK3A40U-4N
KK3A44U-4N

1
1
3
3
3
3
3
2
2
2
4
4
4
4
4
4
4
5
5
5

14 AWG-2 AWG
14 AWG-1/0
14 AWG-2/0 AWG
6 AWG-3/0 AWG
6 AWG-250 kcmil
6 AWG-350 kcmil
2 AWG-600 kcmil
2 AWG-600 kcmil
300 kcmil-800 kcmil
500 kcmil-1000 kcmil
14 AWG-2 AWG
14 AWG-1/0
6 AWG-3/0 AWG
6 AWG-250 kcmil
6 AWG-350 kcmil
2 AWG-600 kcmil
300 kcmil-800 kcmil
2 AWG-600 kcmil
300 kcmil-800 kcmil
500 kcmil-1000 kcmil

11/32
7/16
9/16
9/16
9/16
9/16
9/16
9/16
9/16
9/16
11/32
7/16
9/16
9/16
9/16
9/16
9/16
9/16
9/16
9/16

* Slotted screw.
** ‘‘N” indicates NEMA standard stud holes.

Stud
Hole
Size
5/16
3/8
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
5/16
3/8
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2

Dimensions
D

L

N

W

E

T

H

1.63
2.09
3.06
3.00
3.16
3.16
3.22
3.00
3.34
3.34
1.63
2.09
3.00
3.00
3.00
3.22
3.03
3.00
3.34
3.34

2.19
2.91
3.75
3.88
4.00
4.31
4.69
5.50
6.19
6.19
2.19
2.91
3.88
4.00
4.31
4.69
4.75
5.50
6.19
6.19

0.34
0.34
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.34
0.34
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63

1.59
1.94
1.95
2.81
2.81
3.52
3.63
4.22
4.81
4.75
1.59
1.94
2.81
2.81
3.00
3.63
4.81
4.22
5.34
4.75

0.88
1.00
1.75
1.75
1.75
1.75
1.75
1.75
1.75
1.75
0.88
1.00
1.75
1.75
1.75
1.75
1.75
1.75
1.75
1.75

0.19
0.25
0.19
0.31
0.31
0.31
0.44
0.38
0.56
0.56
0.19
0.25
0.31
0.31
0.31
0.44
0.50
0.38
0.56
0.56

0.62
0.88
1.79
1.12
1.19
1.38
1.56
1.52
1.89
1.90
0.62
0.88
1.12
1.19
1.38
1.56
1.94
1.52
1.89
1.90

Rec.
Tightening ▲
Torque (in-lb)
50
50
50
275
275
275
375
375
375
500
50
50
275
275
275
375
375
375
500
500

▲ Listed torque values are for maximum conductor sizes
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for
smaller conductor sizes.
All 4N items see note LIGHTNING PROTECTION INFO.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPES K4A-U, KK4A-U

A-27

UNIVERSAL TERMINAL
(Four Conductor)
For Aluminum and Copper Conductors

Fig. 1

Fig. 2

These dual-rated four conductor lugs are
constructed from high strength aluminum alloy and
electro tin-plated to provide low contact resistance.

AL9CU
Catalog
Number*

Fig.
No.

FOUR: Wire Range
(Aluminum or Copper)

Stud
Hole
Size

Dimensions
D

L

N

W

E

T

H

Recommended
Tightening
Torque (in-lb)

K4A29U-4N

1

6 AWG-250 kcmil

1/2

3.16

4.25

0.63

3.69

1.75

0.31

1.19

275

K4A31U-4N

1

6 AWG-350 kcmil

1/2

3.00

4.50

0.63

5.04

1.75

0.31

1.38

275

KK4A36U-4N

2

2 AWG-600 kcmil

1/2

3.34

5.63

0.63

5.00

1.75

0.44

1.51

375

KK4A40U-4N

2

300 kcmil-800 kcmil

1/2

3.41

6.19

0.63

6.00

1.75

0.56

1.88

375

* ‘‘N” indicates NEMA standard stud holes.

All 4N items see note LIGHTNING PROTECTION INFO.

TYPES K11A-U, K21A-U,
K22A-U

Fig. 2

Fig. 3

Fig. 1

UNIVERSAL TERMINAL
For Aluminum and Copper Conductors
Dual-rated panelboard lugs are constructed from
high strength extruded aluminum alloy and electro
tin-plated to provide low contact resistance.

Fig. 5

Fig. 4

AL9CU
Wire Range
(Aluminum or Copper)

Stud
Hole
Size

D

L

2

6 AWG-300 kcmil

5/16

0.94

2

4/0 AWG-500 kcmil

1/4

2.31

3

2

2 AWG-600 kcmil

3/8

K21A36U-2

4

3

2 AWG-600 kcmil

K22A36U-2

5

4

2 AWG-600 kcmil

K11A39U-2

3

2

K22A39U-2

5

4

Catalog
Number

Fig.
No.

# of
Conductors

K11A30U

1

K11A34U-2

2

K11A36U-2

H

Recommended
Tightening ▲
Torque (in-lb)

0.50

2.03

275

0.63

2.40

375

1.38

0.75

3.02

375

2.50

1.38

0.75

3.03

375

2.50

1.38

0.75

3.03

375

0.38

1.69

1.38

0.75

3.02

375

0.38

3.06

1.38

0.75

3.02

375

N

W

E

T

3.00

0.47

2.91

0.25

1.00

—

1.44

0.69

2.31

4.91

0.38

1.50

3/8

2.31

3/8

2.31

4.91

0.38

4.91

0.38

1/0 -750 kcmil

3/8

1/0 -750 kcmil

3/8

2.31

4.91

2.31

4.91

▲ Listed torque values are for maximum conductor sizes accommodated. Consult UL486
Tables 7-4, 7-5, 7-6 for smaller conductor sizes.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-28

BURNDY®

TYPES K6A-U, K8A-U,
KK6A-U, KK8A-U
UNIVERSAL TERMINALS
(Six and Eight Conductor)
For Aluminum and
Copper Conductors
Fig. 1

These dual-rated six and eight conductor lugs are
constructed from high strength aluminum alloy and
electro tin-plated to provide low contact resistance.

Fig. 2

Catalog
Number

Fig.
No.

No. of
Conductors

No. of
Mtg
Holes

Wire Range
Aluminum
or Copper

Stud
Hole
Size

Depth

Width

Height

Rec.
Tightening
Torque
in-lb ♦

K6A34U-8

1

6

8

2 AWG - 500 kcmil

9/16

4.63

6.75

1.56

375

K8A34U-10

1

8

10

2 AWG - 500 kcmil

9/16

4.63

8.75

1.56

375

KK6A31U-8

2

6

8

6 AWG - 350 kcmil

9/16

5.31

6.38

1.50

275

KK8A31U-10

2

8

10

6 AWG - 350 kcmil

9/16

5.31

8.13

1.50

275

KK6A34U-8

2

6

8

2 AWG - 500 kcmil

9/16

5.50

6.75

1.50

375

KK8A34U-10

2

8

10

2 AWG - 500 kcmil

9/16

5.50

8.75

1.50

375

KK8A39U-10

2

6

10

2 AWG - 750 kcmil

9/16

6.19

8.25

1.88

550

KK8A39U-12

2

8

12

2 AWG - 750 kcmil

9/16

6.19

10.25

1.88

550

KK6A44U-12

2

6

12

350 kcmil - 1000 kcmil

9/16

6.19

10.00

1.88

550

KK8A44U-14

2

8

14

350 kcmil - 1000 kcmil

9/16

6.19

12.12

1.88

550

♦ Listed torque values are for maximum conductor sizes
accommodated. Consult UL486 Tables 7-4, 7-5, & 7-6
for smaller conductor sizes

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE KAU-KIT

A-29

TRANSFORMER LUG KIT
These dual-rated lugs are constructed from
high strength aluminum alloy and electro tinplated to provide low contact resistance. Lugs and
mounting hardware packaged together in these
kits.

Features & Benefits

• Hardware packed in plastic bag
◊ No lost hardware prior to installation.
• Larger 800 kcmil lugs in KIT3 and KIT4
◊ Accommodates common 750 kcmil tap
conductors in larger transformers.

• UL Listed AL9CU dual rated set screw
terminals and CSA Certified
◊ Ensure the transformer feeders and
taps are terminated properly.
• Plated steel cap screws and hex nuts
with captive conical washers or individual
Belleville washers
◊ Terminal to bus connections are made
using proper hardware resulting in true
torque to pressure performance compensates for dissimilar metal
expansion and contraction.

Terminals

Catalog
Number

Transformer
KVA Rating

Qty

Catalog
Number

Wire Range
Aluminum
or Copper

KAU-KIT1

15 - 37.5 1Ø
15 - 45 3Ø

8
4

KA2U
KA29U

KAU-KIT2

50 - 75 1Ø
75 - 112.5 3Ø

12

KAU-KIT3

100 - 167 1Ø
150 - 300 3Ø

KAU-KIT4

400 - 500 3Ø

Hardware
Qty

Bolt Size

Qty

Nut

Qty

Washer

14 AWG-250
kcmil

8

1/4-20 X 3/4 HH

8

1/4 X 20 HN

-

Captive to Nut

KA29U

6 AWG-250
kcmil

8
8

1/4-20 X 3/4 HH
1/4-20 X 2 HH

16

1/4 X 20 HN

-

Captive to Nut

6
7

K2A31U
K2A40U

6 AWG-800
kcmil

5
6

1/2-13 X 3 HH
1/2-13 X 2-1/2 HH

11

1/2-13 HN

22
11

1/2 FW
1/2 Belleville

15

K2A40U

300 kcmil-800
kcmil

7
4

1/2-13 X 2 HH
1/2-13 X 2-1/2 HH

11

1/2-13 HN

22
11

1/2 FW
1/2 Belleville

HH = Hex Head
HN = Hex Nut
FW = Flat Washer

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-30

BURNDY®

TYPES K-AG1
ALUMINUM NEUTRAL BAR
These aluminum neutral bars are dual rated
for copper and aluminum conductors, and
are manufactured from high strength 6061-T6
aluminum alloy and are electro tin plated to provide
low contact resistance and protection against
corrosion.

Fig. 2

Fig. 1

AL9CU

Fig. 3
Catalog
Number

Fig.

Wire Range
Aluminum or Copper

Total Number
of Holes

Total Number
of Circuits

Mount Hole
Locations

Height

Width

Length

K2P4CAG1

1

14 - 4

3

2

2

0.44

0.31

1.09

K3P4CAG1

1

14 - 4

5

3

1, 5

0.44

0.31

1.67

K9P4CAG1

1

14 - 4

11

9

4, 8

0.44

0.31

3.53

K13P4CAG1

1

14 - 4

15

13

6, 12

0.44

0.31

4.77

K15P4CAG1

1

14 - 4

17

15

6, 14

0.44

0.31

6.01

K5P6C2P1/0CAG1

2

14 - 1/0
14 - 6

7

(5) 14 - 6
(2) 14 - 1/0

–

0.62

0.38

2.26

K12P6C3P1/0CAG1

2

14 - 1/0
14 - 6

15

(12) 14 - 6
(3) 14 - 1/0

–

0.62

0.38

4.34

K14P6C5P1/0CAG1

2

14 - 1/0
14 - 6

19

(14) 14 - 6
(5) 14 - 1/0

–

0.62

0.38

5.77

K16P6C5P1/0CAG1

2

14 - 1/0
14 - 6

23

(16) 14 - 6
(5) 14 - 1/0

–

0.62

0.38

6.97

KAG1MTGBRKT ♦

3

–

–

–

–

–

–

♦ (2) KAG1MTGBRKT are necessary to mount neutral bars into enclosure

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPES K-G1

A-31

COPPER NEUTRAL BAR
These copper neutral bars are manufactured from
high strength pure electrolytic copper to insure
maximum strength and conductivity.

AL9CU

Catalog
Number

Number of
Outlets

K6P4CG1

Conductor Range

Mounting
Holes

Dimensions

Width

Length

Line

Circuit

6

14 - 4

6 - 14

0.20

0.23

0.34

3.56

K8P4CG1

8

14 - 4

6 - 14

0.20

0.47

0.34

4.37

K10P4CG1

10

14 - 4

6 - 14

0.20

0.75

0.34

5.15

K12P4CG1

12

14 - 4

6 - 14

0.20

0.75

0.34

5.94

K14P4CG1

14

14 - 4

6 - 14

0.20

0.75

0.34

6.75

K174P4CG1

174

14 - 4

6 - 14

none

0.47

0.34

69.00

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-32

BURNDY®

TYPE AMS
DUAL RATED SPLICER/REDUCER
For Copper and Aluminum Cable
All splicer/reducers are dual rated for use
with aluminum and copper conductors and
are constructed from high strength, tin plated
aluminum. PENETROX™ oxide inhibiting joint
compounds are recommended for all aluminum
applications.

Features & Benefits
• Large screw diameters
◊ Ensures greater surface contact with
wires for maximum pullout force
• Large cable ranges
◊ Each splice is also an effective
reducing connector

• All connectors are tin-plated
◊ Provide low contact resistance and
prevents galvanic corrosion
• Connectors feature rounded bottoms
◊ Facilitates taping
• Solid center barrier
◊ Prevents contact of dissimilar metals

Catalog
Number

Wire Range
Aluminum & Copper

L

W

H1

H2 Max

Number of
Screws

Screw
Diameter

Hex
Size

AMS-2*

14 AWG-2 AWG

1-19/32

9/16

9/16

0.79

2

3/8

Slot

AMS-0*

14 AWG-1/0

1-29/32

3/4

3/4

0.86

2

7/16

Slot

AMS-4/0

6 AWG-4/0 AWG

2-5/16

1

1-3/32

1.28

2

9/16

5/16

AMS-250

6 AWG-250 kcmil

4-3/32

1

1-3/32

1.29

4

5/8

5/16

AMS-350

6 AWG-350 kcmil

4-11/32

1

1-3/32

1.3

4

11/16

5/16

AMS-500

3/0 AWG-500 kcmil

4-25/32

1-1/4

1-3/8

1.48

4

13/16

3/8

AMS-750

250 kcmil-750 kcmil

6-1/6

1-7/16

1-5/8

1.98

4

15/16

1/2

AMS-1000

500 kcmil-1000 kcmil

8-11/16

1-21/32

1-7/8

2.34

6

1-1/8

9/16

* Slotted Screws. H2 measured with maximum conductors,
reference only.

Complies with NFPA 78-86.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE AGSKIT

A-33

ABOVE GRADE SPLICE KITS
For all Aluminum or Copper/Aluminum
Combinations
Type AGS Above Grade Splice Kit consists of a
standard AMS splice/reducer and a heavy wall
heat-shrink sleeve. The AMS Splice is dual rated
for use with aluminum and copper conductors
and are constructed from high strength, tin plated
aluminum that provides low contact resistance
and reduces the effects of galvanic corrosion.
Connector is installed with common installation
tools. The heavy wall heat shrink sleeve is lined
with adhesive material, providing a positive seal
against moisture egress. Heat shrink sleeve is
installed with standard propane torch, or electric
heat gun.

Fig. 2

Fig. 1

Catalog
Number

Figure
Number

Wire Range

AGSKIT2

1

8 AWG-2 AWG

AGSKIT250

2

1 AWG-250 kcmil

TYPE UGSKIT
WATERTIGHT/
UNDERGROUND SPLICE KITS
For all Aluminum or Copper/Aluminum
Combinations
Type UGS Watertight Underground Splice Kit
consists of a standard AMS splice/reducer and
two heavy wall heat-shrink sleeves. The AMS
Splice is dual rated for use with aluminum and
copper conductors and are constructed from
high strength, tin plated aluminum that provides
low contact resistance and reduces the effects
of galvanic corrosion. Connector installed with
common installation tools. Both heavy wall heat
shrink sleeves are lined with adhesive material,
providing a watertight splice that can withstand
abrasions that may occur during direct burial
applications. Heat shrink sleeve installed with
standard propane torch, or electric heat gun.

Fig. 2

Fig. 1

Catalog
Number

Figure
Number

Wire Range

UGSKIT2*

1

8 AWG-2 AWG

UGSKIT250*

2

1 AWG-250 kcmil

*UL486D Listed for Direct Burial

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-34

BURNDY®

Direct Burial UNITAP™
Connectors
UNITAP™
Dual Rated Multiple Tap Connector
These rubber insulated, dual rated connectors are
for use in networks up to 600V. Suitable in light
fixture pole bases in commercial, industrial, or
residential markets. Distribution within strip malls,
for use in any multi-tenant facility. No taping or
heat shrink required.

Features & Benefits
•	

Dual rated for aluminum or copper
conductors
Each unit is individually marked for
ease of identification
Supplied with aluminum set-screws
Covering is the highest quality
EPDM rubber
Supplied with oxide inhibitor preinstalled

•	
•	
•	
•	

•	
•	
•	
•	
•	

Suitable for direct burial
Meets ANSI C119.1 and C119.4
requirements
Rated 600V and 90° C; UL Listed
and CSA Certified
For use in wet or damp locations
Silicone provided for conductor
insertion

L

W

H

Wire Strip Length
(in)

12 AWG-350 kcmil

2.61

4.06

2.46

1.125

12 AWG-350 kcmil

3.82

4.06

2.46

1.125

Catalog Number

# of Ports

Wire Range
(AWG/kcmil)

BIBS3502DB

2

BIBS3503DB

3

BIBS3504DB

4

12 AWG-350 kcmil

5.03

4.06

2.46

1.125

BIBS3505DB

5

12 AWG-350 kcmil

6.24

4.06

2.46

1.125

BIBS3506DB

6

12 AWG-350 kcmil

7.45

4.06

2.46

1.125

BIBS5003DB

3

10 AWG-500 kcmil

4.31

4.58

3.13

1.50

BIBS5004DB

4

10 AWG-500 kcmil

5.69

4.58

3.13

1.50

BIBS5005DB

5

10 AWG-500 kcmil

7.06

4.58

3.13

1.50

BIBS5006DB

6

10 AWG-500 kcmil

8.44

4.58

3.13

1.50

Recommended Torque Values for Direct Burial UNITAP™

Recommended BURNDY®
Torque Wrench

Conductor Size

Recommended Torque Range

#12 - #6 AWG

125 - 150 in-lbs

BTW30150

#4 - 3/0 AWG

180 - 240 in-lbs

BTW150750

4/0 - 350 AWG

275 - 450 in-lbs

BTW150750

400 - 1000 AWG

475 - 550 in-lbs

BTW150750

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE UGSKIT8

A-35

UF DIRECT BURIAL
SPLICE KIT
Type UGS UF Splice Kit consists of a UF splice
connector and a heavy wall heat-shrink sleeve.
The UF splice connector can accommodate up to
four UF conductors and is installed with common
installation tools. The heavy wall heat shrink
sleeve is lined with an adhesive material, providing
a water-tight splice that can withstand abrasions
that may occur during direct burial applications.
Heat shrink sleeve installed with standard propane
torch, or electric heat gun.
Catalog
Number

Wire Range

UGSKIT8*

14 AWG-8 AWG

Copper

*UL486D Listed for Direct Burial

TYPE UGS350ULDB
IN-LINE SPLICE/REDUCER
For Direct Burial

Features & Benefits
• EPDM rubber covered 6061-T6
aluminum connector
• Dual rated AL9CU for copper or
aluminum conductor
• UL Listed and CSA Certified for Direct
Burial
• Broad range taking capability
• Low installation cost

Catalog Number

Wire Range

Length

Height

Hex Size

Torque (In. Lbs.)

UGS350ULDB

12 AWG-350 kcmil

8.50

2.81

5/16

350

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-36

BURNDY®

BURNDY UNITAP™
THE MOLE™
For Direct Burial
600V, 90° C
Designed specifically for direct burial applications,
the MOLE™ in-line splice/reducer is made with a
specialized plastisol material that forms a rugged
weathertight connection.

Features & Benefits
• UL486D Listed for direct burial.
• AL9CU Dual-rated for copper and
aluminum applications. 600V 90°C.
• Plastisol covered AL6061-T6 aluminum
body saves time by eliminating the need
for heat shrink.
• Oxide inhibitor pre-installed preventing
moisture and contaminants from entering
contact area.
• Range-taking capability reduces the
number of connectors carried in inventory.

Catalog
Number

Number of
Ports

Wire Range (AWG/
kcmil)

L

W

H

Hex Key

Torque
(In.-lbs.)

Wire Strip
Length

BISR4-DB

2

#6 AWG-#4 AWG

4.30

0.68

1.39

1/8

50

7/8"

BISR1-DB

2

#2 AWG-#1 AWG

6.30

0.88

1.75

5/32

130

1-3/32"

BISR3/0-DB

2

1/0 -3/0 AWG

6.25

0.99

1.96

3/16

220

1-3/32"

BISR250-DB

2

4/0 AWG-250 kcmil

6.70

1.18

2.17

5/16

360

1-5/16"

BISR-DB = BURNDY Inline Splice/Reducer Direct Burial.
UNITAP™ rated for code conductor only.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
QGFL

A-37

BARTAP™
For Copper Cable to Flat Bar or
Pad
High copper alloy BARTAP™ for joining a range
of cable to bar or pad. One-wrench installation.
DURIUM™ nut and lockwasher.
Catalog
Number

QGFL1CB1
QGFL1CB1T6
QGFL26B1
QGFL26B1T6
QGFL26B2*
QGFL26B2T6*
QGFL29B1*
QGFL29B1T6*
QGFL31B1*
QGFL31B1T6*
QGFL34B1
QGFL34B1T6
QGFL39B1
QGFL39B1T6
QGFL44B1
QGFL44B1T6
QGFL46B1
QGFL46B1T6
QGFL48B1

Copper
Conductor

#10 Sol-#1 Str
#10 Sol-#1 Str
#8 Sol-#2/0 Str
#8 Sol-#2/0 Str
#8 Sol-#2/0 Str
#8 Sol-#2/0 Str
#6 Str-250 kcmil
#6 Str-250 kcmil
2 AWG-350 kcmil
2 AWG-350 kcmil
1/0 -500 kcmil
1/0 -500 kcmil
350 kcmil-750 kcmil
350 kcmil-750 kcmil
750 kcmil-1000 kcmil
750 kcmil-1000 kcmil
1000 kcmil-1500 kcmil
1000 kcmil-1500 kcmil
1500 kcmil-2000 kcmil

B

H

J

1-1/8
1-1/8
1-1/4
1-1/4
1-1/4
1-1/2
1-2/5
1-5/8
1-3/4
1-3/4
2
2
2-1/4
2-1/4
2-1/4
2-1/4
2-1/4
2-1/4
2-1/4

1-7/8
2-3/8
2-1/8
2-5/8
2-8/25
2-40/50
2-5/8
3-1/8
2-7/8
3-1/4
3-1/8
3-5/8
3-1/4
3-5/8
3-3/8
4-1/8
4
4-1/2
4-3/4

3/8
3/8
3/8
3/8
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2

T
(Max)
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4

W
1
1
1-1/8
1-1/8
1-1/8
1-1/8
1-3/8
1-3/8
1-5/8
1-5/8
1-3/4
1-3/4
1-3/4
1-3/4
2-1/8
2-1/8
2-1/2
2-1/2
3

* Can be installed side by side or in-line on NEMA drilled bar.

FCB
TRANSFORMER TAP ADAPTER
Copper and Aluminum
Cast in one piece from copper alloy. Transformer
tap adapter designed to accommodate from 1
to 6 NEMA drilled copper or aluminum terminal
taps from a single secondary transformer outlet.
Tin-plated. Order mounting hardware and tap
terminals separately.
Catalog
Number
FCB63-4N
FCB63-6N
FCB64-4N
FCB64-6N
FCB65-4N
FCB63-2NP300
FCB64-44NP50

Fig.
No.
1
2
1
2
1
Not Shown
Not Shown

A
Diameter
0.50
0.50
0.75
0.75
1.00
0.50
0.75

Fig. 1
H
Ref.
5.25
5.25
5.75
5.75
7.00
5.00
9.00

L
3.75
5.50
4.00
5.75
4.25
3.50
5.00

P
2.25
2.25
2.75
2.75
4.00
3.00
5.00

Fig. 2

NOTE: All pads are NEMA drilled.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-38

BURNDY®

TYPE KPU-AC
POLYTAP™
Insulated Gutter Tap for All Copper
and Aluminum Combinations
Wide range-taking tin-plated aluminum parallel
clamp and insulating cover assembly for industrial
and multiple story structure applications. Only
six connectors cover the entire 14 Sol.-750 kcmil
range. Covers having flexible fingers that conform
to conductor, fully insulating the connection.
UL486B Listed for 600 volts maximum 90° C
service. Cover and connector are packaged
together. No taping required.
600 Volt Max. 90° C

Conductor
Copper or Aluminum

Catalog
Number

W

H

L

Rec.
Tightening
▲ Torque in-lb

Run

Tap

KPU29A26AC

1/0 -250 kcmil

14 AWG-2/0 AWG

3-1/8

3-3/8

4.24

375

KPU29A29AC

1/0 -250 kcmil

6 AWG-250 kcmil

3-1/8

3-3/8

4.24

375

KPU34A26AC

4/0 AWG-500 kcmil

14 AWG-2/0 AWG

3-1/2

3-1/2

4.58

450

KPU34A34AC

4/0 AWG-500 kcmil

6 AWG-500 kcmil

3-1/2

3-1/2

4.58

450

KPU39A26AC

500 kcmil-750 kcmil

14 AWG-2/0 AWG

3-1/2

3-83/100

5.06

600

KPU39A39AC

500 kcmil-750 kcmil

1/0 -750 kcmil

3-1/2

3-83/100

5.06

600

▲ Listed torque values are for maximum conductor
combinations accommodated. Consult UL486 Tables
7-4, 7-5, 7-6 for smaller combinations.

See note LIGHTNING PROTECTION INFO.

TYPE UCU-AC
RISER TAP
600 VOLT MAX. 90° C MAX.
Parallel-groove riser tap and insulation cover for
copper and aluminum. Wide range-taking assembly
for apartment house and light industrial applications.
Cover and connector are packaged together. Covers
having insulating fingers that conform to conductors,
fully insulating the connection. UL486B Listed for 600
volts max. 90° C service.

Catalog
Number
UCU28AC

Conductor
Copper or Aluminum
Run

Tap

#2 Str.- 4/0 Str.

#10 Sol. - #2 Str.

W

H

L

Recommended
Tightening ▲
Torque in-lb

2-1/4

1-13/16

2-5/8

120

▲ Listed torque values are for maximum conductor
combinations accommodated. Consult UL486 Tables
7-4, 7-5, 7-6 for smaller combinations.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE BIPC

A-39

UL Listed 90° C, *600 Volt
The Type BIPC, BURNDY® Insulation Piercing
Connector is ideally suited for splicing and tapping
aluminum and copper conductor wire sizes: #10
AWG to 500 kcmil.

Features & Benefits
• Insulation piercing capability
◊ Eliminates the need for conductor
insulation stripping.
• UL486B Listed, AL9CU rated
◊ For copper and aluminum conductor
combinations up to 90° *600 Volt
applications.
• Insulation piercing design
◊ For use on hot-line applications eliminates the need for taping.
• Easy snap-out tabs
◊ Eases installation, protects connection
from dirt and debris.
• Simple bolt-on connection
◊ Eases installation.

Fig. 2

Fig. 1

Bolt Size

Socket
Size

H

L

W

Recommended
Tightening
Torque

Max.
Voltage
Rating

2 - 8 AWG

5/16

1/2

2.00

1.53

1.53

180

600 V

4/0 - 1/0 AWG

1/0 - 6 AWG

5/16

1/2

2.50

2.12

2.00

250

300 V

BIPC4/0-1/0

4/0 - 1/0 AWG

4/0 - 1/0 AWG

5/16

1/2

2.50

2.12

2.06

250

300 V

BIPC350-4/0

350 - 4/0 AWG

4/0 - 10 AWG

3/8

9/16

3.00

1.59

2.50

375

300 V

BIPC350-350

350 - 4/0 AWG

350 - 4/0 AWG

3/8

9/16

3.00

2.62

2.75

300

300 V

BIPC500-4/0*

500 - 350 kcmil

4/0 - 4 AWG

3/8

9/16

3.25

1.80

2.62

400

600 V

Conductor Range

Catalog
Number

Run

Tap

BIPC1/0-2*

1/0 - 8 AWG

BIPC4/0-6

* 600 Volt

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-40

BURNDY®

MISCELLANEOUS
ACCESSORIES
TERMINAL BLOCKS
Molded General Purpose Phenolic Base 30
amps,
#10 studs, 1 piece per card, 300-volt rating
Meets UL component requirements
CLASS B:
Commercial Equipment
CLASS C:
General Industrial

300 V RMS
300 V RMS

Withstands volts, Vdc
Steel nickel plated screws

10,500

Catalog
Number

Number of Circuits

General Description

Overall Length

RK149-2

2

2-3/32"

RK150-2

4

3-7/32"

RK225-2

6

RK151-2

8

RK152-2

10

RK226-2

12

Molded General Purpose
Phenolic Base 30 amps, #10 studs
1 piece, per card 300-volt rating

4-11/32"
5-15/32"
6-19/32"
7-23/32"

RK153-2

14

8-27/32"

RK227-2

16

9-31/32"

For bulk pack contact factory.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
POWER DISTRIBUTION
BLOCKS

A-41

U-BLOK™
For Junction Box Applications
FT4B500

The U-BLOK™ system is a modern, state-ofthe-art approach to multi-load power distribution
applications. Among typical uses are multi-story
or multi-unit buildings, HVAC, refrigeration,
control panels, motor control, switch gear, elevator
systems and materials handling equipment.
U-BLOK™ is UL Listed for Copper or Aluminum
conductors and rated for 600-volt applications.
U-BLOK™ can be mounted on bases for use in
troughs or bolted directly to junction boxes. AL9CU
rated.

FT3B4/0

3S

Features & Benefits

3U

raised platforms
◊ Passage of cables under block means
through-cables need not be terminated
• Insulating covers and mounting blocks
rated 94-VO
◊ Saves costly taping, time and material.
Conforms to or exceeds building codes.
• Connectors accommodate a wide range
of wire sizes
◊ Reduces parts inventory requirements.
• Feeder conductors can be cut or fed
through on a continuous run
◊ Ease of installation.

• Connector top slides OFF/ON for quick
cable lay-in
◊ Labor savings. Easy access for
installation, modifications or retrofit.
• Electro-tin plated connectors in each
pole
◊ Durability. High-conductivity and
resistance to corrosion.
• Compact size
◊ Requires less space than traditional
connection methods.
• Trough installations can be mounted on

3 WIRE POWER DISTRIBUTION BLOCKS
Catalog
Number

Max. Number of
Wires per Phase

FT3B4/0
FT3B500
3S

2
2
2

3U

1 Run / 8 Tap

Conductor
Copper or Aluminum*
Run
Tap
3/0 - 4/0
6 - 4/0
400 - 500
6 - 500
250 - 350
6 - 350
3/0 - 500

6 - 1/0

W

L

H

Weight
Each

3-7/8
3-7/8
3-5/8

5-7/8
5-7/8
9-3/4

4-1/8
4-1/8
4-7/8

1-1/4
2-1/8
3

Allen
Wrench
Size
1/4
3/8
1/4

4-3/4

9-3/4

5-1/2

3

5/32

Recommended
Tightening
Strip Length
Torque
200
1-1/2
375
2-5/16
200
1-3/4
2-5/16 (Run);
110
1-5/32 (Tap)

4 WIRE POWER DISTRIBUTION BLOCKS
Catalog
Number

Max. Number of
Wires per Phase

FT4B4/0
FT4B500
4S

2
2
2

4U

1 Run / 8 Tap

Conductor
Copper or Aluminum*
Run
Tap
3/0 - 4/0
6 - 4/0
400 - 500
6 - 500
250 - 350
6 - 350

W

L

H

Weight
Each

3-7/8
3-7/8
3-5/8

7-7/8
7-7/8
11-3/4

4-1/8
4-1/8
4-7/8

3/0 - 500

4-3/4

11-3/4

5-1/2

6 - 1/0

PENETROX™ inhibitor is recommended for all aluminum
wire connections.
For two wire tap range is 8 through 1/0.

2
2-3/4
3-1/2

Allen
Wrench
Size
1/4
3/8
1/4

Recommended
Tightening
Torque
200
375
200

3-1/2

5/32

110

Strip
Length
1-1/2
2-5/16
1-3/4
2-5/16 (Run);
1-5/32 (Tap)

* Aluminum and copper conductors cannot be assembled
under the same pressure plate or t-bar.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-42

BURNDY®

U-BLOK™ MOUNTING
PLATFORMS
For Trough Applications

Gutter
Size

Catalog
Number

W

L

TBPT6*

4-1/4

5-7/8

1-1/2

6'

3/4

TBPT8

4-1/4

7-7/8

3-1/2

8"

1-1/4

TBPT10

4-1/4

9-7/8

4

10"

1-1/2

TBPT12

4-1/4

11-7/8

4

12"

1-3/4

H

Weight Each (lb)

Hole pattern shown is for reference only.
* Supercedes TBPT4/0-6 and TBPT350/500-6.

FLEXI-TAP™
ALLOWABLE AMPACITIES OF INSULATED CONDUCTOR, 60° TO 90° C **
Copper

Al or Copper Clad Al

Size AWG
kcmil

60 deg. C

75 deg. C

90 deg. C

60 deg. C

75 deg. C

90 deg. C

12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750

25
30
40
55
70
85
95
110
125
145
165
195
215
240
260
280
320
355
385
400

25
35
50
65
85
100
115
130
150
175
200
230
255
285
310
335
380
420
460
475

30
40
55
75
95
110
130
150
170
195
225
260
290
320
350
380
430
475
520
535

20
25
30
40
55
65
75
85
100
115
130
150
170
190
210
225
260
285
310
320

20
30
40
50
65
75
90
100
120
135
155
180
205
230
250
270
310
340
375
385

25
35
45
60
75
85
100
115
135
150
175
205
230
255
280
305
350
385
420
435

** NOTE: Values referenced from Article 310 of the National Electric Code, Table 310-16, 1996. The above
chart is to be used for REFERENCE ONLY. Please consult Table 310-16 of the National Electric Code (latest revision) for information regarding insulation type, voltage range, and conductor housings/surroundings.
U-TAP™, U-BLOK™, and SPEC-BLOK™ connectors are rated for 90 deg. C by Underwriters’ Laboratories.
Use of 60 deg. C and 75 deg. C conductor(s) is valid, though only as determined by the National Electric
Code.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
SPEC-BLOK™
POWER DISTRIBUTION
CONNECTORS

A-43

Unique, modular, made-to-order, power distribution
assemblies accommodate any number of supply
and load conductors in any number of poles.
Capacity matches the conductors accommodated
and SPEC-BLOK™ assures uniform loading.
Adjacent poles are separated by easy-to handle,
wrap-around insulating covers which eliminate
taping and reduce heat build-up by allowing air to
flow freely around connectors. SPEC-BLOK™ is
UL Listed for copper or aluminum conductors for
600 volts. (AL9CU) Assemblies are mounted on
platforms suitable for easy installation in wireway
or junction box.

Features & Benefits
• Accommodate unlimited conductors
◊ Fits wide range of applications.
Eliminates need for non-UL-Listed
improvisation.
• Connector elements tin-plated
◊ Provides high reliability,
low-resistance connections.
• User friendly, space-saving design
◊ Easy to install - saves labor.
• 94-VO rated insulation folds into
place insulating the components
◊ Saves time and material. Allows
easy installation.
• Connector caps removable for easy
cable lay-in
◊ Saves labor. Makes installation
easier - allows installation of
straight-through conductors.
Eases retrofit.
• Belleville washers built-in on

pressure screw assemblies, except
in assemblies installed with a 5/32"
Allen wrench
◊ Provides high-integrity connections.
• Conductors can be cut or fed straight
through
◊ Straight through installation ideal
for riser applications.

Contact BURNDY® or Technical Services: 1-800-451-4956,
or BURNDY® Customer Service: 1-800-346-4175

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-44

BURNDY®

SPEC-BLOK™

Features & Benefits
• 2 Wire (series), 4 (parallel), and
Multi-Tap versions available
◊ Nearly any conductor combination can
be terminated
• Tin-plated Aluminum Alloy Construction
◊ High-strength, corrosion-resistant
connector elements
• All SPEC-BLOK™ connectors are
custom made for nearly any Power
Distribution system requirement
◊ Time savings — pre-assembled in our
factory for immediate installation!

• The SPEC-BLOK™ system includes
12 connector elements
◊ A wide variety of conductor sizes can
be accommodated
• Each element can be bolted together
in parallel
◊ Provides an efficient flow of current
from one element to another
• AL9CU rated for Copper or Aluminum
conductors
◊ Dual-rated system, with UL486B’s
highest temperature rating

A

E

W

D

S

SPEC-BLOK™ CONNECTORS

C

B

T

Catalog Designation
(Maximum
Conductor)

R

Number of
Conductors
Accommodated

Q
(2/0)

B

R
(250)

C

S
(350)

D

1 to 4
(0, 1 or 2
per cap)

P

Dimensions
Length Without Insulator

Second
Conductor
(if required)
May Be

Height On
Max
Conductors

Width

4
Conductor

2
Conductor

1/0 - 2/0

#12 - 2/0

2-9/16"

1-1/2"

2-1/8"

7/8"

3/0 - 250

#6 - 250

3-1/8"

1-11/16"

4-1/4"

1-3/8"

Allen
Wrench
Size

5/32"

1/4"

1 or 2
per cap

T
(500)

E

U

AL or CU
Wire Range Under
Each Cap

First
4
2
4
2
Conductors
Conductor Conductor Conductor Conductor
MUST Be
A

Q

250 - 350

#6 - 350

3-5/16"

1-13/16"

4-5/8"

1-1/2"

400 - 500

#6 - 500

4-1/16"

2"

5-5/8"

1-3/4"
3/8"

W

600 - 750

(750)

3/0 - 750

4-7/8"

2-1/4"

7-1/4"

Catalog Designation
(Maximum Conductor)

Number of Conductors
Accommodated

Large
Groove

Small
Grooves**

Height On
Maximum
Conductors

Width

P (1/0)

1 to 8 (0, 1 or 2 under each screw)

__

6 - 1/0

3-1/2"

2"

U (1/0 & 500)

2 to 9 (0, 1 or 2 under each screw
plus one large conductor)

3/0 - 500

6 - 1/0

4-1/8"

2"

2-5/8"

Length
Without
Insulator

Allen
Wrench
Size

1-3/4"

5/32"

** This range may be expanded to include #8 provided two conductors are being installed in that particular element.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
SPEC-BLOK™

A-45

MOUNTING PLATFORMS
SPEC-BLOK™ Mounting Platforms
are rigid steel construction with a
black finish.
They can be supplied for junction box mounting or
wireway construction allowing trough conductors
to pass underneath the assemblies.

(CPB-)

(CPT-)

Catalog
Number
CPB6
CPB8
CPB10
CPB12
CPB14
CPB16-5/8
CPB21-1/4

L
(Nominal)
6
8
10
12
14
16-5/8
21-1/4

Catalog
Number
CPT6
CPT8
CPT10
CPT12
CPT16

L
(Nominal)
5-7/8
7-7/8
9-7/8
11-7/8
15-7/8

SPEC-BLOK™ catalog numbers describe exactly how
the distribution block is assembled:

L
(Overall)
7-3/4
9-3/4
11-3/4
13-3/4
15-3/4
18-3/8
23
H
2-1/4
3
3-1/2
4
4

W
(Overall)
2-1/2
2-1/2
2-1/2
3-1/2
3-1/2
3-1/2
3-1/2
W
(Overall)
2-1/2
3-1/2
3-1/2
3-1/2
3-1/2

5DR-NDST-GQP-12 (assembly pictured)

Total number of poles in the
completed assembly

5
DR

One ‘D’ unit and one ‘R’ unit, bolted in parallel,
forming each phase pole (3 phase poles)

N

Denotes the beginning of the neutral pole (where
required)

DST

One ‘D’ unit, one ‘S’ unit, and one ‘T’ unit, bolted
in parallel, forming the neutral pole

G

Denotes the beginning of the ground pole
description (where required)

QP

One ‘Q’ unit and one ‘P’ unit,
bolted in parallel, forming the ground pole

12

Size (inches) of the wireway or trough that is needed to enclose the assembly. If a junction box enclosure is used, no number is used to denote the
size of the enclosure

SPEC-BLOK™ IS A SYSTEM THAT CAN SOLVE MOST POWER DISTRIBUTION APPLICATIONS!
Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-46

BURNDY®

Questionnaire

For spec-blok™ Applications

How many poles in the system? (3-wire, 4-wire, single phase, etc.)?___________ poles
Are neutral conductors (when required) different sizes (AWG/kcmil) than the phase conductors?
___________ same size	 ___________ different size
Is a ground connection required?

□ Yes □ No

What are the quantities, sizes (AWG/kcmil) and material (AI/Cu) of the incoming line conductors
and outgoing load conductors?
QUANTITY

PER PHASE

PER PHASE

SIZE

CONDUCTOR TYPE

LINE
LOAD
LINE
LOAD

PER PHASE

LINE
LOAD

Are any conductors continuous?

□ Yes □ No

If yes, which ones? ______________________________________________________________________________________
_______________________________________________________________________________________________________
What kind of enclosure is the connection assembly being mounted in and what are the inside space dimensions?
Wireway/trough size _______________________________________________________________________________________
Box, panel, cabinet, other size _______________________________________________________________________________
When is a quotation required? Date ___________________ When is the material required? Date __________________
Name of requestor __________________________________ Job name/reference ________________________________
Is there a preference for a particular BURNDY distributor?

□ Yes □ No

If yes, please give the name, location and telephone number
Name ________________________________________________________________ Phone______________________________
Address ________________________________________________________________________________________________
________________________________________________________________________________________________

Questions?items
Call BURNDY
Technical
at frequently
800-451-4956.
Blue highlighted
are industry
standardServices
and most
ordered.
®

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
UL LISTED
POWER DISTRIBUTION
BLOCKS

A-47

VERSIPOLE™

These Power Distribution Blocks are Listed to the
Power Distribution Block Standard UL 1953. They
contain the same features and characteristics
as the non-Listed blocks however, these have
spacings that are suitable for installations in
most industrial control panel feeder and branch
circuits, HVAC systems, and Wireways (with
optional cover; sold separately). They are
available in one, two, or three pole configurations.
An “Adder” is also available with optional End
Barrier (sold separately), to allow user customized
configurations.

Features & Benefits
•	
•	
•	
•	
•	
•	
•	

•	

Single or dual run connections allow the
user to minimize the number of connections
required
Suitable for use with aluminum or copper
conductors providing maximum versatility
Available in 3 sizes for optimization of space
600V, ALCU Rated; meets or exceeds
industry standard requirements
Range taking designs to accommodate wire
sizes up to 600 kcmil
High Short-Circuit Rating up to 100kA with
proper fusing
Meets spacing requirements of Industrial
Control Panel Standard UL 508A (spacing
of 1” through air and 2” over surface)

•	

1

Adders and End Barriers available separately for all 3 sizes providing capability to
create as many poles as required
Hinged Covers available separately to cover
3 sizes providing user protection and easy
access to connector terminal block

Short-Circuit Current Rating with proper fusing

Small Series:
Connector

Run

Tap

Number
of Run(s)

Number
of Tap(s)

Wire
Range
AL9CU

Wire
Range
AL9CU

Width

Height

Depth

Ampere
Rating per
Pole

Number
of Poles

SCCR1

BDCSHC142/01

1

4

14-2/0

14-4

1.05

2.81

3.08

175

1

100kA

BDASHC142/01

1

4

14-2/0

14-4

0.93

2.81

3.08

175

Adder

100kA

BDCSHC112/01

1

1

14-2/0

14-2/0

1.05

2.81

3.08

175

1

100kA

BDASHC112/01

1

1

14-2/0

14-2/0

0.93

2.81

3.08

175

Adder

100kA

Catalog Number

Small Series Hinged Cover and End Barrier:
Catalog Number

Description

BDASHCEB

End Barrier for Small Series Adder Distribution Blocks

BDBSHCCOVER

Hinged Cover for use with Small Series Distribution Blocks and Adders (use of End Barrier necessary with Adders to attach
cover). Order 1 cover per pole

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-48

BURNDY®

UL LISTED
POWER DISTRIBUTION
BLOCKS
VERSIPOLE™
Medium Series:
Catalog Number

Connector

Run

Tap

Number Number
of Run(s) of Tap(s)

Wire
Range
AL9CU

Wire
Range
AL9CU

Width

Height

Depth

Ampere
Rating per
Pole

Number of
Poles

SCCR1

BDBMHC162/01

1

6

14-2/0

14-2

1.85

3.25

5

175

1

100kA

BDBMHC162/02

1

6

14-2/0

14-2

3.57

3.25

5

175

2

100kA

BDBMHC162/03

1

6

14-2/0

14-2

5.28

3.25

5

175

3

100kA

BDAMHC162/0

1

6

14-2/0

14-2

1.72

3.25

5

175

Adder

100kA

BDBMHC112/01

1

1

14-2/0

14-2/0

1.85

3.25

5

175

1

100kA

BDBMHC112/02

1

1

14-2/0

14-2/0

3.57

3.25

5

175

2

100kA

BDBMHC112/03

1

1

14-2/0

14-2/0

5.28

3.25

5

175

3

100kA

BDAMHC112/0

1

1

14-2/0

14-2/0

1.72

3.25

5

175

Adder

100kA

BDBMHC113501

1

1

6-350

6-350

1.85

3.25

5

310

1

100kA

BDBMHC113502

1

1

6-350

6-350

3.57

3.25

5

310

2

100kA

BDBMHC113503

1

1

6-350

6-350

5.28

3.25

5

310

3

100kA

BDAMHC11350

1

1

6-350

6-350

1.72

3.25

5

310

Adder

100kA

BDBMHC262/01

2

6

14-2/0

14-2

1.85

3.25

5

350

1

100kA

BDBMHC262/02

2

6

14-2/0

14-2

3.57

3.25

5

350

2

100kA

BDBMHC262/03

2

6

14-2/0

14-2

5.28

3.25

5

350

3

100kA

BDAMHC262/0

2

6

14-2/0

14-2

1.72

3.25

5

350

Adder

100kA

BDBMHC222/01

2

2

14-2/0

14-2/0

1.85

3.25

5

350

1

100kA

BDBMHC222/02

2

2

14-2/0

14-2/0

3.57

3.25

5

350

2

100kA

BDBMHC222/03

2

2

14-2/0

14-2/0

5.28

3.25

5

350

3

100kA

BDAMHC222/0

2

2

14-2/0

14-2/0

1.72

3.25

5

350

Adder

100kA

BDBMHC145001

1

4

4-500

14-2/0

1.85

3.25

5

380

1

100kA

BDBMHC145002

1

4

4-500

14-2/0

3.57

3.25

5

380

2

100kA

BDBMHC145003

1

4

4-500

14-2/0

5.28

3.25

5

380

3

100kA

BDAMHC14500

1

4

4-500

14-2/0

1.72

3.25

5

380

Adder

100kA

BDBMHC1625001

1

6

4-500

14-2

1.85

3.25

5

380

1

100kA

BDBMHC1625002

1

6

4-500

14-2

3.57

3.25

5

380

2

100kA

BDBMHC1625003

1

6

4-500

14-2

5.28

3.25

5

380

3

100kA

BDAMHC162500

1

6

4-500

14-2

1.72

3.25

5

380

Adder

100kA

Medium Series Hinged Cover and End Barrier:
Catalog Number

Description

BDAMHCEB

End Barrier for Medium Series Adder Distribution Blocks

BDBMHCCOVER

Hinged Cover for use with Medium Series Distribution Blocks and Adders (use of End Barrier necessary with Adders to attach
cover). Order 1 cover per pole

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
UL LISTED
POWER DISTRIBUTION
BLOCKS

A-49

VERSIPOLE™
Large Series:
Connector

Run

Tap
Width

Height

Depth

Ampere
Rating per
Pole

Number
of Poles

SCCR1

14-4

2.73

3.55

5.7

310

1

100kA

14-4

5.31

3.55

5.7

310

2

100kA

14-4

7.89

3.55

5.7

310

3

100kA

6-350

14-4

2.58

3.55

5.7

310

Adder

100kA

6-350

4-2/0

2.73

3.55

5.7

310

1

100kA

6

6-350

4-2/0

5.31

3.55

5.7

310

2

100kA

1

6

6-350

4-2/0

7.89

3.55

5.7

310

3

100kA

1

6

6-350

4-2/0

2.58

3.55

5.7

310

Adder

100kA

BDBLHC115001

1

1

4-500

4-500

2.73

3.55

5.7

380

1

100kA

BDBLHC115002

1

1

4-500

4-500

5.31

3.55

5.7

380

2

100kA

BDBLHC115003

1

1

4-500

4-500

7.89

3.55

5.7

380

3

100kA

BDALHC11500

1

1

4-500

4-500

2.58

3.55

5.7

380

Adder

100kA

BDBLHC165001

1

6

4-500

4-2/0

2.73

3.55

5.7

380

1

100kA

BDBLHC165002

1

6

4-500

4-2/0

5.31

3.55

5.7

380

2

100kA

BDBLHC165003

1

6

4-500

4-2/0

7.89

3.55

5.7

380

3

100kA

BDALHC16500

1

6

4-500

4-2/0

2.58

3.55

5.7

380

Adder

100kA

BDBLHC2125001

2

12

4-500

14-4

2.73

3.55

5.7

760

1

100kA

Catalog Number

Number
of Run(s)

Number
of Tap(s)

Wire
Range
AL9CU

Wire
Range
AL9CU

BDBLHC1123501

1

12

6-350

BDBLHC1123502

1

12

6-350

BDBLHC1123503

1

12

6-350

BDALHC112350

1

12

BDBLHC163501

1

6

BDBLHC163502

1

BDBLHC163503
BDALHC16350

BDBLHC2125002

2

12

4-500

14-4

5.31

3.55

5.7

760

2

100kA

BDBLHC2125003

2

12

4-500

14-4

7.89

3.55

5.7

760

3

100kA

BDALHC212500

2

12

4-500

14-4

2.58

3.55

5.7

760

Adder

100kA

BDBLHC263501

2

6

6-350

14-2/0

2.73

3.55

5.7

620

1

100kA

BDBLHC263502

2

6

6-350

14-2/0

5.31

3.55

5.7

620

2

100kA

BDBLHC263503

2

6

6-350

14-2/0

7.89

3.55

5.7

620

3

100kA

BDALHC26350

2

6

6-350

14-2/0

2.58

3.55

5.7

620

Adder

100kA

BDBLHC223501

2

2

6-350

6-350

2.73

3.55

5.7

620

1

100kA

BDBLHC223502

2

2

6-350

6-350

5.31

3.55

5.7

620

2

100kA

BDBLHC223503

2

2

6-350

6-350

7.89

3.55

5.7

620

3

100kA

BDALHC22350

2

2

6-350

6-350

2.58

3.55

5.7

620

Adder

100kA

BDBLHC225001

2

2

4-500

4-500

2.73

3.55

5.7

760

1

100kA

BDBLHC225002

2

2

4-500

4-500

5.31

3.55

5.7

760

2

100kA

BDBLHC225003

2

2

4-500

4-500

7.89

3.55

5.7

760

3

100kA

BDALHC22500

2

2

4-500

4-500

2.58

3.55

5.7

760

Adder

100kA

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-50

BURNDY®

UL LISTED
POWER DISTRIBUTION
BLOCKS
VERSIPOLE™

Large Series (continued):
Connector

Run

Tap

Catalog Number

Number
of Run(s)

Number
of Tap(s)

Wire
Range
AL9CU

Wire
Range
AL9CU

Width

Height

Depth

Ampere
Rating per
Pole

Number of
Poles

SCCR1

BDBLHC265001

2

6

4-500

14-2/0

2.73

3.55

5.7

760

1

100kA

BDBLHC265002

2

6

4-500

14-2/0

5.31

3.55

5.7

760

2

100kA

BDBLHC265003

2

6

4-500

14-2/0

7.89

3.55

5.7

760

3

100kA

BDALHC26500

2

6

4-500

14-2/0

2.58

3.55

5.7

760

Adder

100kA

BDBLHC245001

2

4

4-500

6-4/0

2.73

3.55

5.7

760

1

100kA

BDBLHC245002

2

4

4-500

6-4/0

5.31

3.55

5.7

760

2

100kA

BDBLHC245003

2

4

4-500

6-4/0

7.89

3.55

5.7

760

3

100kA

BDALHC24500

2

4

4-500

6-4/0

2.58

3.55

5.7

760

Adder

100kA

BDBLHC226001

2

2

2-600

2-600

2.73

3.55

5.7

840

1

100kA

BDBLHC226002

2

2

2-600

2-600

5.31

3.55

5.7

840

2

100kA

BDBLHC226003

2

2

2-600

2-600

2.73

3.55

5.7

840

3

100kA

BDALHC22600

2

2

2-600

2-600

2.58

3.55

5.7

840

Adder

100kA

Large Series Hinged Cover and End Barrier:
Catalog Number

Description

BDALHCEB

End Barrier for Large Series Adder Distribution Blocks

BDBLHCCOVER

Hinged Cover for use with Large Series Distribution Blocks and Adders (use of End Barrier necessary with Adders to attach cover).
Order 1 cover per pole

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
VERSIPOLE™

A-51

POWER DISTRIBUTION
BLOCKS
VERSIPOLE™ Power Distribution Blocks are
designed to provide modular solutions to power
distribution applications. Each connector element
is made from a high conductivity aluminum alloy
which is insulated with a high strength polymer
housing. One, two, and three pole versions
available. “Add” a pole (snap-together) blocks are
also available for wire sizes up to 500 kcmil. For
use with Cu or Al. 600 V, AL9CU rated.

VERSIPOLE™
Snap-Together Blocks

Features and Benefits
• “Add” a pole feature available
◊ Provides capability to create as many
poles as required
• Up to 30 tap conductors accommodated
◊ Ideal for current distribution to multiple
locations
• Single or dual run connections
◊ Allows user to minimize the number of
connectors needed to do the job
• Suitable for use with aluminum or copper
conductors

◊ Provides maximum versatility
• 600 V, AL9CU rated*
◊ Meets or exceeds industry standard
requirements
• Dead-front covers available
◊ Provides user protection – one cover
per pole
* BDB-430-500-1 not CSA certified

Run

Tap

Wire Range
AL9CU

Wire Range
AL9CU

Ampere
Rating per
Pole

Number of
Poles

BDA-112-350

AWG 6 - 350 kcmil

AWG 14 - 4

310

ADDER

BDA-16-350

AWG 6 - 350 kcmil

AWG 14 - 2/0

310

ADDER

BDA-16-500

AWG 4 - 500 kcmil

AWG 4 - 2/0

380

ADDER

BDA-26-350

AWG 6 - 350 kcmil

AWG 14 - 2/0

620

ADDER

BDA-212-500

AWG 4 - 500 kcmil

AWG 14 - 4

760

ADDER

BDA-26-500

AWG 4 - 500 kcmil

AWG 14 - 2/0

760

ADDER

BDA-24-500

AWG 4 - 500 kcmil

AWG 6 - 4/0

760

ADDER

BDA-11-500

AWG 4 - 500 kcmil

AWG 4 - 500 kcmil

380

ADDER

BDA-22-350

AWG 6 - 350 kcmil

AWG 6 - 350 kcmil

620

ADDER

BDA-22-500

AWG 4 - 500 kcmil

AWG 4 - 500 kcmil

760

ADDER

Catalog
Number

Connector
Run

Tap

NOTES:
1. Order Optional BDB COVER1 per pole if desired.
2. Snap-together blocks can also be assembled to 1, 2, 3
pole blocks to create multi-pole distribution blocks.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-52

BURNDY®

VERSIPOLE™
VERSIPOLE™ 1, 2, 3 Pole
Distribution Blocks

Run

Tap

Wire Range
AL9CU

Wire Range
AL9CU

Ampere
Rating per
Pole

Number
of
Poles

Optional
Cover Order
1 per Pole

BDB-16-2/0-1
BDB-16-2/0-2
BDB-16-2/0-3

AWG 12 - 2/0

AWG 14 - 4

175

1
2
3

BDBCOVER2

BDB-26-2/0-1
BDB-26-2/0-2
BDB-26-2/0-3

AWG 14 - 2/0

AWG 14 - 2

350

1
2
3

BDBCOVER2

BDB-112-350-1
BDB-112-350-2
BDB-112-350-3

AWG 6 - 350 kcmil

AWG 14 - 4

310

1
2
3

BDBCOVER1

BDB-16-350-1
BDB-16-350-2
BDB-16-350-3

AWG 6 - 350 kcmil

AWG 14 - 2/0

310

1
2
3

BDBCOVER1

BDB-14-500-1
BDB-14-500-2
BDB-14-500-3

AWG 4 - 500 kcmil

AWG 14 - 2/0

380

1
2
3

BDBCOVER2

BDB-16-500-1
BDB-16-500-2
BDB-16-500-3

AWG 4 - 500 kcmil

AWG 14 - 2/0

380

1
2
3

BDBCOVER1

BDB-162-500-1
BDB-162-500-2
BDB-162-500-3

AWG 4 - 500 kcmil

AWG 14 - 2

380

1
2
3

BDBCOVER2

BDB-26-350-1
BDB-26-350-2
BDB-26-350-3

AWG 6 - 350 kcmil

AWG 14 - 2/0

620

1
2
3

BDBCOVER1

BDB-212-500-1
BDB-212-500-2
BDB-212-500-3

AWG 4 - 500 kcmil

AWG 14 - 4

760

1
2
3

BDBCOVER1

BDB-26-500-1
BDB-26-500-2
BDB-26-500-3

AWG 4 - 500 kcmil

AWG 14 - 2/0

760

1
2
3

BDBCOVER1

BDB-24-500-1
BDB-24-500-2
BDB-24-500-3

AWG 4 - 500 kcmil

AWG 6 - 4/0

760

1
2
3

BDBCOVER1

Connector
Catalog
Number

Run

Tap

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
VERSIPOLE™

A-53

VERSIPOLE™ 1, 2, 3
Splice/Reducer Blocks
Run

Tap

Wire Range
AL9CU

Wire Range
AL9CU

Ampere
Rating per
Pole

BDB-11-2/0-1
BDB-11-2/0-2
BDB-11-2/0-3

AWG 14 - 2/0

AWG 14 - 2/0

175

1
2
3

BDBCOVER2

BDB-11-350-1
BDB-11-350-2
BDB-11-350-3

AWG 6 - 350 kcmil

AWG 6 - 350 kcmil

310

1
2
3

BDBCOVER2

BDB-11-500-1
BDB-11-500-2
BDB-11-500-3

AWG 6 - 500 kcmil

AWG 6 - 500 kcmil

380

1
2
3

BDBCOVER1

BDB-22-2/0-1
BDB-22-2/0-2
BDB-22-2/0-3

AWG 14 - 2/0

AWG 14 - 2/0

350

1
2
3

BDBCOVER2

BDB-22-350-1
BDB-22-350-2
BDB-22-350-3

AWG 6 - 350 kcmil

AWG 6 - 350 kcmil

620

1
2
3

BDBCOVER1

BDB-22-500-1
BDB-22-500-2
BDB-22-500-3

AWG 4 - 500 kcmil

AWG 4 - 500 kcmil

760

1
2
3

BDBCOVER1

Run

Tap

Wire Range
AL9CU

Wire Range
AL9CU

Ampere
Rating per
Pole

Number of
Poles

Optional
Cover Order
1 per Pole

BDC-14-2/0-1

AWG 14 - 2/0

AWG 14 - 4

175

1

BDBCOVER3

BDA-14-2/0-1

AWG 14 - 2/0

AWG 14 - 4

175

ADDER

BDBCOVER3

BDC-11-2/0-1

AWG 14 - 2/0

AWG 14 - 2/0

175

1

BDBCOVER3

BDA-11-2/0-1

AWG 14 - 2/0

AWG 14 - 2/0

175

ADDER

BDBCOVER3

Connector
Catalog
Number

Run

Tap

Number of
Poles

Optional
Cover Order
1 per Pole

SNAP TOGETHER
SPLICE/REDUCER
BLOCKS
Connector
Catalog
Number

Run

Tap

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-54

BURNDY®

VERSIPOLE™
(Continued)

These tables and illustrations refer to the specific
VERSIPOLE™ Power Distribution Blocks listed.

VERSIPOLE™ 1, 2, 3
Splice/Reducer Blocks

The Figure to the Lower Right is Applicable to the Following:
Number of Poles

Catalog Number

Number of Poles

BDA-11-500

Catalog Number

1 (adder)

BDB-16-500-3

3

BDA-112-350

1 (adder)

BDB-212-500-1

1

BDA-16-350

1 (adder)

BDB-212-500-2

2

BDA-16-500

1 (adder)

BDB-212-500-3

3

BDA-212-500

1 (adder)

BDB-22-350-1

1

BDA-22-350

1 (adder)

BDB-22-350-2

2

BDA-22-500

1 (adder)

BDB-22-350-3

3

BDA-24-500

1 (adder)

BDB-22-500-1

1

BDA-26-350

1 (adder)

BDB-22-500-2

2

BDA-26-500

1 (adder)

BDB-22-500-3

3

BDB-11-500-1

1

BDB-24-500-1

1

BDB-11-500-2

2

BDB-24-500-2

2

BDB-11-500-3

3

BDB-24-500-3

3

BDB-112-350-1

1

BDB-26-350-1

1

BDB-112-350-2

2

BDB-26-350-2

2

BDB-112-350-3

3

BDB-26-350-3

3

BDB-16-350-1

1

BDB-26-500-1

1

BDB-16-350-2

2

BDB-26-500-2

2

BDB-16-350-3

3

BDB-26-500-3

3

BDB-16-500-1

1

BDB-430-500-1*

1

BDB-16-500-2

2

* BDB-430-500-1 not CSA certified

No. of
Poles

Dimensions A
Inches

Adder
1
2
3
N

2.50
2.81
5.31
7.81
(2.50 X N) + 0.31

Example for 10 poles:
A = (2.50 X 10) + 0.31 = 25

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
VERSIPOLE™

A-55

(Continued)

VERSIPOLE™ 1, 2, 3
Splice/Reducer Blocks
These tables and illustrations refer to the specific
VERSIPOLE™ Power Distribution Blocks listed.

The Figure to the Lower Right is
Applicable to the Following:
Catalog Number
Number of Poles

BDB-11-2/0-1
BDB-11-2/0-2
BDB-11-2/0-3
BDB-11-350-1
BDB-11-350-2
BDB-11-350-3
BDB-14-500-1
BDB-14-500-2
BDB-14-500-3
BDB-16-2/0-1
BDB-16-2/0-2
BDB-16-2/0-3
BDB-162-500-1
BDB-162-500-2
BDB-162-500-3
BDB-22-2/0-1
BDB-22-2/0-2
BDB-22-2/0-3
BDB-26-2/0-1
BDB-26-2/0-2
BDB-26-2/0-3

1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

No. of
Poles

Dimensions A
Inches

Adder
1
2
3
N

1.64
1.94
3.57
5.20
(1.64 X N) + 0.30

Example for 10 poles:
A = (1.64 X 10) + 0.30 = 16.20

Applicable VERSI-POLETM Items
Catalog Number
Number of Poles

BDA-14-2/0-1
BDC-14-2/0-1
BDA-11-2/0-1
BDC-11-2/0-1

1 (adder)
1
1 (adder)
1

No. of
Poles

Dimensions A
Inches

Adder
1
2
3
N

0.81
1.08
1.89
2.70
(0.81 X N) + 0.27

Example for 10 poles:
A = (.81 X 10) + 0.30 = 8.37

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-56

BURNDY®

TYPES BIT, BITO, BISR
UNITAP™
Clear Insulated Multiple Tap
Connectors

Fig. 1

Tap connections and in-line splice/reductions are
made quickly and easily with the UNITAP™ line
of connectors. UL486B Listed. Dual-rated AL9CU
for any stranded copper or stranded aluminum
applications. 600 Volt, 90° C.

2 Port, 1 or 2 Sided Entry
Catalog
Number
BIT4
BITO4
BIT2/0
BITO2/0
BIT250
BITO250
BIT350
BITO350
BIT600
BITO600
BIT750 *
BITO750 *

# of
Ports
2
2
2
2
2
2
2
2
2
2
2
2

Fig. 2

Features & Benefits
• Clear Plastisol covered AL6061-T6
aluminum body
◊ Saves time, lowers installation
costs, eliminates taping.
• Clear Plastisol
◊ Allows visual confirmation that
conductor is properly inserted.
• Oxide inhibitor pre-installed
◊ Inhibits moisture and contaminants
from entering the contact area.
• Range-taking
◊ Reduces number of connectors
carried in inventory.

Wire Range
(AWG/kcmil)

L

14 AWG-4 AWG

1.16

14 AWG-2/0 AWG

1.52

10 AWG-250 kcmil

2.03

10 AWG-350 kcmil

2.22

4 AWG-600 kcmil

2.72

2 AWG-750 kcmil

2.87

W
1.16
1.50
1.40
1.56
2.07
2.64
2.32
3.00
2.38
3.00
2.70
3.38

H

Hex
Key

1.25

1/8

1.38

3/16

2.13

5/16
3/16
5/16
3/16
3/8
3/16
3/8

2.50
2.75
3.00

Figure
Number
1
2
1
2
1
2
1
2
1
2
1
2

* BIT750 and BITO750 are not UL Listed.
UNITAP™ rated for code conductor only.

In-Line Splicer/Reducer
Catalog
Number

Wire Range
(AWG/kcmil)

L

W

H

Hex Key

BISR2

#14-2

2.38

0.75

1.22

5/32

BISR1/0

#14-1/0

2.91

0.91

1.38

3/16

BISR250

#10-250

4.01

1.19

2.10

5/16

BISR350

#10-350

4.63

1.34

2.35

5/16

BISR500

#6-500

5.00

1.62

2.62

3/8

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE BIBS

A-57

UNITAP™
Clear Insulated Multiple Tap
Connectors
Tap connections and in-line splice/reductions are
made quickly and easily with the UNITAP™ line
of connectors. UL486B Listed. Dual-rated AL9CU
for any stranded copper or stranded aluminum
applications. 600 Volt, 90° C.

Features & Benefits
• Clear Plastisol covered AL6061-T6
aluminum body
◊ Saves time, lowers installation
costs, eliminates taping
• Clear Plastisol
◊ Allows visual confirmation that
conductor is properly inserted

• Oxide inhibitor pre-installed
◊ Inhibits moisture and contaminants
from entering the contact area
• Range-taking
◊ Reduces number of connectors
carried in inventory

MULTI-PORT
Single-Sided Entry
Catalog
Number
BIBS4-3
BIBS4-4
BIBS4-5
BIBS4-6
BIBS4-8
BIBS2/0-3
BIBS2/0-4
BIBS2/0-5
BIBS2/0-6
BIBS2/0-8
BIBS2/0-10
BIBS2/0-12
BIBS2/0-14
BIBS250-3
BIBS250-4
BIBS250-5
BIBS250-6
BIBS250-8
BIBS250-10
BIBS250-12
BIBS250-14
BIBS350-3
BIBS350-4
BIBS350-5
BIBS350-6
BIBS350-8
BIBS350-10

# of
Ports

Wire Range
(AWG/kcmil)

L

W

H

Hex
Key

3

14 AWG-4 AWG

1.51

1.25

1.25

1/8

4

14 AWG-4 AWG

1.95

1.25

1.25

1/8

5

14 AWG-4 AWG

2.39

1.25

1.25

1/8

6

14 AWG-4 AWG

2.83

1.25

1.25

1/8

8

14 AWG-4 AWG

3.71

1.25

1.25

1/8

3

14 AWG-2/0 Str

2.19

1.31

1.38

3/16

4

14 AWG-2/0 Str

2.86

1.31

1.38

3/16

5

14 AWG-2/0 Str

3.53

1.31

1.38

3/16

6

14 AWG-2/0 Str

4.20

1.31

1.38

3/16

8

14 AWG-2/0 Str

5.55

1.31

1.38

3/16

10

14 AWG-2/0 Str

6.89

1.31

1.38

3/16

12

14 AWG-2/0 Str

8.24

1.31

1.38

3/16

14

14 AWG-2/0 Str

9.58

1.31

1.38

3/16

3

10 AWG-250 kcmil

2.97

2.07

2.13

5/16

4

10 AWG-250 kcmil

3.91

2.07

2.13

5/16

5

10 AWG-250 kcmil

4.84

2.07

2.13

5/16

6

10 AWG-250 kcmil

5.78

2.07

2.13

5/16

8

10 AWG-250 kcmil

7.66

2.07

2.13

5/16

10

10 AWG-250 kcmil

9.53

2.07

2.13

5/16

12

10 AWG-250 kcmil 11.41

2.07

2.13

5/16

14

10 AWG-250 kcmil 13.29

2.07

2.13

5/16

3

10 AWG-350 kcmil

3.13

2.32

2.50

5/16

4

10 AWG-350 kcmil

4.04

2.32

2.50

5/16

5

10 AWG-350 kcmil

4.95

2.32

2.50

5/16

6

10 AWG-350 kcmil

5.86

2.32

2.50

5/16

8

10 AWG-350 kcmil

7.68

2.32

2.50

5/16

10

10 AWG-350 kcmil

9.50

2.32

2.50

5/16

Catalog
Number
BIBS350-12
BIBS350-14
BIBS600-3
BIBS600-4
BIBS600-5
BIBS600-6
BIBS600-8
BIBS600-10
BIBS600-12
BIBS600-14
BIBS750-3*
BIBS750-4*
BIBS750-6*
BIBS750-8*
BIBS750-10*
BIBS750-12*
BIBS750-14*

# of
Ports

Wire Range
(AWG/kcmil)

L

W

H

Hex
Key

12

10 AWG-350 kcmil 11.32

2.32

2.50

5/16

14

10 AWG-350 kcmil 13.14

2.32

2.50

5/16

3

4 AWG-600 kcmil

4.00

2.38

2.75

3/8

4

4 AWG-600 kcmil

5.28

2.38

2.75

3/8

5

4 AWG-600 kcmil

6.56

2.38

2.75

3/8

6

4 AWG-600 kcmil

7.84

2.38

2.75

3/8

8

4 AWG-600 kcmil

10.41

2.38

2.75

3/8

10

4 AWG-600 kcmil

12.97

2.38

2.75

3/8

12

4 AWG-600 kcmil

15.53

2.38

2.75

3/8

14

4 AWG-600 kcmil

18.09

2.38

2.75

3/8

3

2 AWG-750 kcmil

4.00

2.70

3.00

3/8

4

2 AWG-750 kcmil

5.38

2.70

3.00

3/8

6

2 AWG-750 kcmil

8.13

2.70

3.00

3/8

8

2 AWG-750 kcmil

10.88

2.70

3.00

3/8

10

2 AWG-750 kcmil

13.63

2.70

3.00

3/8

12

2 AWG-750 kcmil

16.38

2.70

3.00

3/8

14

2 AWG-750 kcmil

19.13

2.70

3.00

3/8

NOTE: Only 1 conductor per port allowed.
* Not UL Listed.
UNITAP™ rated for code conductor only.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-58

BURNDY®

TYPE BIBD
UNITAP™
Clear Insulated Multiple Tap
Connectors
Tap connections and in-line splice/reductions are
made quickly and easily with the UNITAP™ line
of connectors. UL486B Listed. Dual-rated AL9CU
for any stranded copper or stranded aluminum
applications. 600 Volt, 90° C.

Features & Benefits
• Oxide inhibitor pre-installed
◊ Inhibits moisture and contaminants
from entering the contact area
• Range-taking
◊ Reduces number of connectors
carried in inventory

• Clear Plastisol covered AL6061-T6
aluminum body
◊ Saves time, lowers installation costs,
eliminates taping
• Clear Plastisol
◊ Allows visual confirmation that
conductor is properly inserted

MULTI-PORT
Double-Sided Entry
Catalog
Number
BIBD4-2
BIBD4-3
BIBD4-4
BIBD4-5
BIBD4-6
BIBD4-8
BIBD2/0-2
BIBD2/0-3
BIBD2/0-4
BIBD2/0-5
BIBD2/0-6
BIBD2/0-8
BIBD2/0-10
BIBD2/0-12
BIBD2/0-14
BIBD250-2
BIBD250-3
BIBD250-4
BIBD250-5
BIBD250-6
BIBD250-8
BIBD250-10
BIBD250-12
BIBD250-14
BIBD350-2
BIBD350-3

# of
Ports

Wire Range
(AWG/kcmil)

W

L

H

Hex
Key

2

14 AWG-4 Str

1.50

1.08

1.25

1/8

3

14 AWG-4 Str

1.50

1.51

1.25

1/8

4

14 AWG-4 str

1.50

1.95

1.25

1/8

5

14 AWG-4 Str

1.50

2.39

1.25

1/8

6

14 AWG-4 Str

1.50

2.83

1.25

1/8

8

14 AWG-4 str

1.50

3.71

1.25

1/8

2

14 AWG-2/0 Str

1.56

1.52

1.38

3/16

3

14 AWG-2/0 Str

1.56

2.19

1.38

3/16

4

#14-2/0 Str

1.56

2.86

1.38

3/16

5

#14-2/0 Str

1.56

3.53

1.38

3/16

6

14 AWG-2/0 Str

1.56

4.20

1.38

3/16

8

14 AWG-2/0 Str

1.56

5.55

1.38

3/16

10

14 AWG-2/0 Str

1.56

6.89

1.38

3/16

12

14 AWG-2/0 Str

1.56

8.24

1.38

3/16

14

14 AWG-2/0 Str

1.56

9.58

1.38

3/16

2

10 AWG-250 kcmil

2.64

2.03

2.13

5/16

3

10 AWG-250 kcmil

2.64

2.97

2.13

5/16

4

10 AWG-250 kcmil

2.64

3.91

2.13

5/16

5

10 AWG-250 kcmil

2.64

4.84

2.13

5/16

6

10 AWG-250 kcmil

2.64

5.78

2.13

5/16

8

10 AWG-250 kcmil

2.64

7.66

2.13

5/16

10

10 AWG-250 kcmil

2.64

9.53

2.13

5/16

12

10 AWG-250 kcmil

2.64

11.41

2.13

5/16

14

10 AWG-250 kcmil

2.64

13.29

2.13

5/16

2

10 AWG-350 kcmil

3.00

2.22

2.50

5/16

3

10 AWG-350 kcmil

3.00

3.13

2.50

5/16

Catalog
Number
BIBD350-4
BIBD350-5
BIBD350-6
BIBD350-8
BIBD350-10
BIBD350-12
BIBD350-14
BIBD600-2
BIBD600-3
BIBD600-4
BIBD600-5
BIBD600-6
BIBD600-8
BIBD600-10
BIBD600-12
BIBD600-14
BIBD750-2*
BIBD750-3*
BIBD750-4*
BIBD750-6*
BIBD750-8*
BIBD750-10*
BIBD750-12*
BIBD750-14*

# of
Ports

Wire Range
(AWG/kcmil)

W

L

H

Hex
Key

4

10 AWG-350 kcmil

3.00

4.04

2.50

5/16

5

10 AWG-350 kcmil

3.00

4.95

2.50

5/16

6

10 AWG-350 kcmil

3.00

5.86

2.50

5/16

8

10 AWG-350 kcmil

3.00

7.68

2.50

5/16

10

10 AWG-350 kcmil

3.00

9.50

2.50

5/16

12

10 AWG-350 kcmil

3.00

11.32

2.50

5/16

14

10 AWG-350 kcmil

3.00

13.14

2.50

5/16

2

4 AWG-600 kcmil

3.00

2.56

2.75

3/8

3

4 AWG-600 kcmil

3.00

3.77

2.75

3/8

4

4 AWG-600 kcmil

3.00

4.97

2.75

3/8

5

4 AWG-600 kcmil

3.00

6.17

2.75

3/8

6

4 AWG-600 kcmil

3.00

7.37

2.75

3/8

8

4 AWG-600 kcmil

3.00

9.78

2.75

3/8

10

4 AWG-600 kcmil

3.00

12.97

2.75

3/8

12

4 AWG-600 kcmil

3.00

15.53

2.75

3/8

14

4 AWG-600 kcmil

3.00

18.09

2.75

3/8

2

2 AWG-750 kcmil

3.38

2.87

3.00

3/8

3

2 AWG-750 kcmil

3.38

4.25

3.00

3/8

4

2 AWG-750 kcmil

3.38

5.63

3.00

3/8

6

2 AWG-750 kcmil

3.38

8.37

3.00

3/8

8

2 AWG-750 kcmil

3.38

11.13

3.00

3/8

10

2 AWG-750 kcmil

3.38

13.87

3.00

3/8

12

2 AWG-750 kcmil

3.38

16.63

3.00

3/8

14

2 AWG-750 kcmil

3.38

19.37

3.00

3/8

NOTE: Only 1 conductor per port allowed.
* Not UL Listed.
UNITAP™ rated for code conductor only.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE BIBS-MT, BIBD-MT

A-59

UNITAP™
Clear Insulated Multiple Tap
Connectors Mounting Version

Fig. 1

The BIBS-MT and BIBD-MT series UNITAP™
offer the same multi-port capabilities as the
standard UNITAP™ connectors except these -MT
types are provided with two isolated mounting
holes at both ends of the connector for direct
mounting to a trough, gutter or wireway. They will
accommodate up to standard 1/4" hardware.

Fig. 2

MULTI-PORT
Single-Sided Entry
Catalog
Number

Fig.
#

# of
Ports

MULTI-PORT
Double-Sided Entry
Wire Range
(AWG/kcmil)

L

W

H

Hex
Key

Catalog
Number

Fig.
#

# of
Ports

Wire Range
(AWG/kcmil)

L

W

H

Hex
Key

BIBS2/04MT

1

4

#14 -2/0 Str

4.20

1.25

1.50

3/16

BIBD2/04MT

2

4

14 AWG-2/0 AWG

4.20

1.56

1.50

3/16

BIBS2/06MT

1

6

#14 -2/0 Str

5.54

1.25

1.50

3/16

BIBD2/06MT

2

6

14 AWG-2/0 AWG

5.54

1.56

1.50

3/16

BIBS2/08MT

1

8

14 AWG-2/0 Str

6.89

1.25

1.50

3/16

BIBD2/08MT

2

8

14 AWG-2/0 AWG

6.89

1.56

1.50

3/16

BIBS2/010MT

1

10

14 AWG-2/0 Str

8.23

1.25

1.50

3/16

BIBD2/010MT

2

10

14 AWG-2/0 AWG

8.23

1.56

1.50

3/16

BIBS2/012MT

1

12

14 AWG-2/0 Str

9.58

1.25

1.50

3/16

BIBD2/012MT

2

12

14 AWG-2/0 AWG

9.58

1.56

1.50

3/16

BIBS2504MT

1

4

10 AWG-250 kcmil

5.78

1.95

2.63

5/16

BIBD2504MT

2

4

10 AWG-250 kcmil

5.78

2.64

2.26

5/16

BIBS2506MT

1

6

10 AWG-250 kcmil

7.65

1.95

2.63

5/16

BIBD2506MT

2

6

10 AWG-250 kcmil

7.65

2.64

2.26

5/16

BIBS2508MT

1

8

10 AWG-250 kcmil

9.53

1.95

2.63

5/16

BIBD2508MT

2

8

10 AWG-250 kcmil

9.53

2.64

2.26

5/16

BIBS25010MT

1

10

10 AWG-250 kcmil

11.41

1.95

2.63

5/16

BIBD25010MT

2

10

10 AWG-250 kcmil

11.41

2.64

2.26

5/16

BIBS25012MT

1

12

10 AWG-250 kcmil

13.28

1.95

2.63

5/16

BIBD25012MT

2

12

10 AWG-250 kcmil

13.28

2.64

2.26

5/16

BIBS3504MT

1

4

10 AWG-350 kcmil

5.86

2.19

2.63

5/16

BIBD3504MT

2

4

10 AWG-350 kcmil

5.86

3.00

2.63

5/16

BIBS3506MT

1

6

10 AWG-350 kcmil

7.68

2.19

2.63

5/16

BIBD3506MT

2

6

10 AWG-350 kcmil

7.68

3.00

2.63

5/16

BIBS3508MT

1

8

10 AWG-350 kcmil

9.50

2.19

2.63

5/16

BIBD3508MT

2

8

10 AWG-350 kcmil

9.50

3.00

2.63

5/16

BIBS35010MT

1

10

10 AWG-350 kcmil

11.32

2.19

2.63

5/16

BIBD35010MT

2

10

10 AWG-350 kcmil

11.32

3.00

2.63

5/16

BIBS35012MT

1

12

10 AWG-350 kcmil

13.41

2.19

2.63

5/16

BIBD35012MT

2

12

10 AWG-350 kcmil

13.41

3.00

2.63

5/16

BIBS6004MT

1

4

4 AWG-600 kcmil

7.84

2.25

2.88

3/8

BIBD6004MT

2

4

4 AWG-600 kcmil

7.84

3.00

2.88

3/8

BIBS6006MT

1

6

4 AWG-600 kcmil

10.41

2.25

2.88

3/8

BIBD6006MT

2

6

4 AWG-600 kcmil

10.41

3.00

2.88

3/8

BIBS6008MT

1

8

4 AWG-600 kcmil

12.97

2.25

2.88

3/8

BIBD6008MT

2

8

4 AWG-600 kcmil

12.97

3.00

2.88

3/8

BIBS60010MT

1

10

4 AWG-600 kcmil

15.53

2.25

2.88

3/8

BIBD60010MT

2

10

4 AWG-600 kcmil

15.53

3.00

2.88

3/8

BIBS60012MT

1

12

4 AWG-600 kcmil

18.09

2.25

2.88

3/8

BIBD60012MT

2

12

4 AWG-600 kcmil

18.09

3.00

2.88

3/8

UNITAP™ rated for code conductor only.

UNITAP™ rated for code conductor only.

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-60

BURNDY®

UV RATED
BLACK UNITAP™

Features & Benefits
• UV Rated Plastisol covered AL6061-T6
aluminum body saves time by eliminating
the need for taping.
• Oxide inhibitor pre-installed inhibits
moisture and contaminants from entering
the contact area.
• Range-taking capability reduces the
number of connectors carried in inventory.
• UL486B Listed, AL9CU, 600V 90°C.

UNITAP™
600V, 90°C

Catalog Number
1PL42
1PLO42
1PL2/02
1PLO2/02
1PL2502
1PLO2502
1PL3502
1PLO3502
1PL6002
1PLO6002
1PBS2

# of
Ports

Wire Range
(AWG/kcmil)

L

W

H

Hex Key

Torque

2
2
2
2
2
2
2
2
2
2
2

14 AWG-4 AWG
14 AWG-4 AWG
14 AWG-2/0 AWG
14 AWG-2/0 AWG
10 AWG-250 kcmil
10 AWG-250 kcmil
10 AWG-350 kcmil
#10-350 kcmil
10 AWG-600 kcmil
4 AWG-600 kcmil
14 AWG-2 AWG

1.08
1.08
1.52
1.52
2.03
2.03
2.22
2.22
2.72
2.72
2.38

1.16
1.50
1.40
1.56
2.07
2.64
2.32
3.00
2.38
3.00
0.75

1.25
1.25
1.38
1.38
2.13
2.13
2.50
2.50
2.75
2.75
1.22

1/8
1/8
3/16
3/16
5/16
5/16
5/16
5/16
3/8
3/8
5/32

45
45
120
120
275
275
275
275
375
375
45

1PBS1/0

2

14 AWG-1/0

2.91

0.91

1.38

3/16

120

1PBS250
1PBS350
1PBS500
1PL43
1PL44
1PL2/03
1PL2503
1PLD43
1PLD44
1PLD2/02
1PLD2/03
1PLD2/04
1PLD2/06
1PLD2502
1PLD2503
1PLD2504
1PLD2506
1PLD3502
1PLD3503
1PLD3504
1PLD3506
1PLD3508
1PLD6002
1PLD6003
1PLD6004
1PLD6005
1PLD6006
1PLD6008

2
2
2
3
4
3
3
3
4
2
3
4
6
2
3
4
6
2
3
4
6
8
2
3
4
5
6
8

10 AWG-250 kcmil
10 AWG-350 kcmil
6 AWG-500 kcmil
14 AWG-4 AWG
14 AWG-4 AWG
14 AWG-2/0 AWG
10 AWG-250 kcmil
14 AWG-4 AWG
14 AWG-4 AWG
14 AWG-2/0 AWG
14 AWG-2/0 AWG
14 AWG-2/0 AWG
14 AWG-2/0 AWG
10 AWG-250 kcmil
10 AWG-250 kcmil
10 AWG-250 kcmil
10 AWG-250 kcmil
10 AWG-350 kcmil
10 AWG-350 kcmil
10 AWG-350 kcmil
10 AWG-350 kcmil
10 AWG-350 kcmil
4 AWG-600 kcmil
4 AWG-600 kcmil
4 AWG-600 kcmil
4 AWG-600 kcmil
4 AWG-600 kcmil
4 AWG-600 kcmil

4.01
4.63
5.00
1.51
1.95
2.19
2.97
1.51
1.95
1.52
2.19
2.86
4.20
2.03
2.97
3.91
5.78
2.22
3.13
4.04
5.86
7.68
2.72
4.00
5.28
6.56
7.84
10.40

1.19
1.34
1.62
1.25
1.25
1.31
2.07
1.50
1.50
1.56
1.56
1.56
1.56
2.64
2.64
2.64
2.64
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00

2.10
2.35
2.62
1.25
1.25
1.38
2.13
1.25
1.25
1.38
1.38
1.38
1.38
2.13
2.13
2.13
2.13
2.50
2.50
2.50
2.50
2.50
2.75
2.75
2.75
2.75
2.75
2.75

5/16
1/3
3/8
1/8
1/8
3/16
1/3
1/8
1/8
1/5
3/16
3/16
3/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
3/8
3/8
3/8
3/8
3/8
3/8

120
275
375
45
45
120
275
45
45
120
120
120
120
275
275
275
275
375
375
375
375
375
375
375
375
375
375
375

1PL = 2 Port Single Sided Entry
1PLO = 2 Port Offset Entry

1PBS = In-line Splice/Reducer
1PL = Multi-Port Single Sided Entry

1PLD = Multi-Port Double Sided Entry
UNITAP™ rated for code conductor only.

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487

Mechanical

BURNDY®
TYPE BWTE

A-61

WALL-MOUNTED TERMINATION
ENCLOSURES
These are three-phase, NEMA 3R
(rain-proof), 600 Volt Rated wall
mounted termination enclosures.

AL9CU

Features and Benefits

• Manufactured to meet or exceed ANSI
C57-12.28 for wall-mounted equipment
enclosure integrity
• Three-point positive latch mechanism
(secured and operated by a half-turn,
captive and recessed penta-head bolt)
and shielded padlock shackle
• Finish meets or exceeds proposed EEI
paint specification
• Finish is gray, oven cured powder coat
• All mounting hardware is 18-8 stainless
steel

• Aluminum mechanical bar connectors
eliminates need for compressions tools,
lugs, and bolt assemblies
• Aluminum enclosure is lightweight, low
maintenance and has excellent corrosion
resistance
• Ample working space, allowing for easier
termination with a removeable swinging
door
• All-welded construction: welds and
seams are ground smooth
Dimensions

UL Listed Amp Rating

Catalog
Number

Conductor
Range (AWG)

Number of
Conductors
per phase

W

D

H

Door
Opening

Copper

Aluminum

BWTE21-500

10 - 500 kcmil

21

32.00

16.00

51.00

28.00

3800

3100

BWTE21-750

2 - 750 kcmil

14

32.00

16.00

51.00

28.00

3325

2695

BWTE21-1000

1/0 - 1000 kcmil

14

32.00

16.00

51.00

28.00

3815

3115

Blue highlighted items are industry standard and most frequently ordered.

Canada: 1-800-387-6487			

www.burndy.com	

	

US: 1-800-346-4175

Mechanical
A-62

BURNDY®

TYPE BPTE
PAD-MOUNTED TERMINATION
ENCLOSURES
These are three-phase, NEMA 3R
(rain-proof), 600 Volt Rated pad
mounted termination enclosures.

Features and Benefits

• Manufactured to meet or exceed ANSI
C57-12.28 for wall-mounted equipment
enclosure integrity
• Removable swinging doors - doors have
stainless steel lift off hinges with
stainless steel three point locking
handles and recessed stainless steel
penta-head bolts for security
• Finish is Munsell green, oven cured
powder coat
• All mounting hardware is 18-8 stainless
steel

• Aluminum mechanical bar connectors
eliminates need for compressions tools,
lugs and bolt assemblies
• Aluminum enclosure is lightweight, low
maintenance and has excellent corrosion
resistance
• Ample working space, allowing for easier
termination with a removeable swinging
door
• All-welded construction: welds and
seams are ground smooth
Dimensions

UL Listed Amp Rating

Catalog
Number

Conductor
Range (AWG)

Number of
Conductors
per phase

W

D

H

Door
Opening

Copper

Aluminum

BPTE26-500

10 - 500 kcmil

26

36.00

30.00

44.00

30.00

4560

3720

BPTE22-750

2 - 750 kcmil

22

36.00

30.00

44.00

30.00

5225

4235

BPTE20-1000

350 - 1000 kcmil

20

36.00

30.00

44.00

30.00

4905

4005

BPTE14-750

2 - 750 kcmil

14

25.00

24.00

44.00

19.00

3800

3100

Blue highlighted items are industry standard and most frequently ordered.

US: 1-800-346-4175		

www.burndy.com	

	

Canada: 1-800-387-6487



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2014:01:15 16:16:44-05:00
Creator                         : Adobe Acrobat 9.2.0
Modify Date                     : 2014:01:18 13:04:02-05:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2014:01:18 13:04:02-05:00
Creator Tool                    : Adobe Acrobat 9.2.0
Format                          : application/pdf
Document ID                     : uuid:129b0d41-a186-4731-8455-e6815ce5c933
Instance ID                     : uuid:9736ef48-858f-47c2-a9b5-a5532ae5e0c2
Producer                        : Adobe Acrobat 9.2.0
Page Count                      : 62
EXIF Metadata provided by EXIF.tools

Navigation menu