94641 Catalog
137889-Attachment 137889-Attachment 137889-Attachment Batch10 unilog cesco-content
2014-05-17
: Pdf 94641-Catalog 94641-Catalog 781810 batch2_2 unilog
Open the PDF directly: View PDF .
Page Count: 62
Download | |
Open PDF In Browser | View PDF |
Mechanical BURNDY® TABLE OF CONTENTS Types KS, KS-3, SC A-3 Type K2A-U A-25 Type KSU A-4 Types K3A-U, KK3A-U A-26 Type KSA A-5 Types KVS, KVSU A-6 Types K4A-U, KK4A-U, K11A-U, K21A-U, K22A-U A-27 Types KVSW, KVS-A A-1 UL Listed Distribution Blocks A-47 to A-50 Power Distribution Blocks, Splice/Reducer Blocks A-51 to A-55 Types BIT, BITO, BISR A-56 A-7 Types K6A-U, K8A-U, KK6A-U, KK8A-U A-28 Type QPX A-8 Type KAU-KIT A-29 Type BIBS A-57 Type QPX-Y A-9 Type K-AG1 A-30 Type BIBD A-58 Types KPA, KPA-UP A-10 Type K-G1 A-31 Types BIBS-MT, BIBD-MT A-59 Type KLU A-11 Type AMS A-32 Type 1PL A-60 Types KA, EA A-12 Types AGSKIT, UGSKIT A-33 Type BWTE A-61 Type BGBL A-13 Type BIBS-DB A-34 Type BPTE A-62 Types UGSKIT8, UGS350ULDB A-35 Type BISR-DB A-36 Types QGFL, FCB A-37 Types KPU-AC, UCU-AC A-38 Type BIPC A-39 Terminal Blocks A-40 U-BLOK and Platforms A-41, A-42 Types CL50-1, CL50-1TN, CL A-14 Types QA, QQA A-15 Types Q2A, Q3A A-16 Types QB, Q2B A-17 Types QDA, QR A-18 Types VT, E-C-G A-19 Types VA, VVA A-20 Type HFB-P1 A-21 Type HFB-N A-22 Types KA-U, KKA-U A-23 Type KA-UAR A-24 ™ SPEC-BLOK ™ A-43 to A-46 Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-2 BURNDY® LIGHTNING PROTECTION INFO. Basic rules for selection are: 1. 2. 3. 4. Must be like material to the conductor. Two bolts to ground rod - minimum. Cable to cable connections can be anything, one bolt, two bolt, compression, etc. Cable to steel structure must have 8 square inch contact with steel. 5. 6. Heavy duty stacks - mechanical only. On all connectors with heavy duty stack rating, we must offer 1/16” thick lead plating as an option. The reason for that is closest 25 ft. to stack opening must use lead coated product. SPECIAL FEATURES Other features are also available for products listed, such as undrilled or special drilling, 45° or 90° pad angles, belling for extra flexible cable, smooth or special threaded studs, special label- REVOLUTIONARY BURNDY® DESIGN MEETS STRICT UL486B STANDARDS ing or packaging, extra long braid, and nuclear certification. Please contact BURNDY Customer Service for any inquiries. ... and puts the bite on aluminum connections forever! For use on all combinations • • • Aluminum to aluminum Aluminum to copper Copper to copper Complies with NFPA 78-86 Ordinary Structures. Complies with NFPA 78-86 Heavy Duty Stacks. (Order: LD for Lead Plating for Heavy Duty Stack applications.) ALL OTHER SPECIAL REQUESTS PLEASE CONTACT BURNDY CUSTOMER SERVICE 1-800-346-4175 Unique “bite and grip” TRITAP™ SERVIT® contact delivers safe, long-term reliability — even without scratch brushing ... without oxide inhibiting compounds.† † When used in NEC applications of insulated cables only. Patented Available in sizes from #10 through 500 kcmil Triangular edges bite into cable to break through surface oxides: • provide low contact resistance • produces gas tight seal Spacer provides built-in separation to retard galvanic corrosion Tin-plated contact surface inhibits oxide formation Anti-galling, high efficiency threaded components result in high contact force. Easily installed using standard, everyday wrenches. Special heat-treated hard, aluminum alloy Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPES KS & KS-3 A-3 SERVIT® For Copper, Copperweld Compact, high strength, high copper alloy SERVIT® split-bolt has free-running threads and easy to grip wrench flats. Highly resistant to season cracking and corrosion, the SERVIT® provides maximum pressure and assures a secure connection on all combinations of run and tap conductors. Type KS-3 accommodates 3 maximum size conductors. Catalog Number Cross Flats † KS90 † KS15 † KS17 * KS17-3 † KS20 * KS20-3 † KS22 * KS22-3 † KS23 † KS25 † KS26 † KS27 † KS29 † KS31 † KS34 KS39 KS44 L 0.50 0.50 0.63 0.62 0.69 0.68 0.75 0.74 0.82 0.94 1.05 1.36 1.36 1.70 1.82 2.31 2.56 0.85 0.85 1.14 0.98 1.20 1.17 1.50 1.33 1.54 1.77 1.94 1.86 2.07 2.51 2.79 3.29 3.73 W 0.38 0.38 0.45 0.70 0.51 0.78 0.60 0.84 0.62 0.73 0.82 1.17 1.17 1.41 1.48 1.94 2.19 Conductor Copper ▲ Copperweld Maximum Run and Tap Equal Run & Tap Min Tap with Max Run Sol. Str. Type A Type D Recommended Tightening Torque (in-lb) 12 - 10 Str. 10 - 8 Str. 8 Str. - 6 Sol. 8 Str. - 6 Sol. 8 Str. - 4 Sol. 8 Str. - 4 Sol. 6 Str. - 2 Sol. 6 Str. - 2 Sol. 6 Str. - 2 Str. 4 Str. - 1/0 Str. 2 Str. - 2/0 Str. 1 Str. - 3/0 Str. 1 Str. - 250 1/0 Str. - 350 2/0 Str. - 500 4/0 Str. - 750 300 - 1000 16 Str. 14 Str. 14 Str. 16 Str. 14 Str. 14 Str. 14 Str. 14 Str. 14 Str. 14 Str. 14 Str. 8 Sol. 8 Str. 1/0 Str. 2/0 Str. 4/0 Str. 4/0 Str. #10 #8 #6 #6 #4 #4 #2 #2 #1 2/0 3/0 — 4/0 — — — — — — 3 #12 3 #12 3 #10 3 #10 3 #8 3 #8 3 #7 3 #5 7 #7 — 7 #5 19 #8 19 #6 19 #5 — — — 8A 8A 6A 6A 4A 4A 3A 2A — — — — — — — — — 9-1/2D 9-1/2D 8D 8D 6D 6D 5D 4D — — — — — — — 80 80 165 165 165 165 275 275 275 385 385 500 650 650 825 1000 1100 ▲ Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor combinations. See note LIGHTNING PROTECTION INFO. * Not UL Listed or CSA Certified. † In addition to UL Listed for wire connectors and CSA Certified, these items are also UL rated for direct burial. TYPE SC SERVIT® COVER HUG-A-BUG Used indoors or outdoors, this compact, one-piece plastic SERVIT® cover saves time and material, eliminates costly taping of split-bolts. Positive latch snaps easily and quickly over connector, ideal for tight quarters. Self-positioning plastic fingers wrap around wires fully insulating joint. UL Listed for 600 volt indoor application with type KS. Three covers accommodate a range of 6 SERVIT® sizes through 2/0 Str. Catalog Number For Use With SC4 KS17, KS17-3, KS20, KSU17, KSU20 SC2 KS22, KS20-3, KS23, KS22-3, KSA6, KSA4, KSU22, KSU23 SC2/0 KS25, KS26, KSA2, KSA1/0, KSU25, KSU26 Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-4 BURNDY® TYPE KSU UNIVERSAL SERVIT® For Use On All Combinations of Copper, Aluminum, ACSR, AAAC, 5005, and Steel Tin-plated, high strength, copper alloy SERVIT® with spacer. Spacer separates dissimilar conductors and provides long contact length that prevents high pressure point contacts between run and tap conductors. Copper Only 486A Copper Only Use of PENETROX™ joint compound recommended with Aluminum and ACSR. Conductor Catalog Number Cross Flats L KSU17 0.62 0.92 KSU20 0.69 KSU22 Run W Steel (Max Conductor) Tap Recommended Tightening Torque (in-lb) Copper & Aluminum ACSR AAAC 5005 Copper & Aluminum ACSR AAAC 5005 Sol. BWG 3 Str. BWG Nom. Dia. 0.42 12 Sol. - 6 Sol. 8 (6-1) 12 Sol. - 6 Sol. 8 (6-1) 8 — 5/32 165 1.05 0.48 10 Sol. - 4 Sol. 6 (6-1) 10 Sol. - 4 Sol. 6 (6-1) 6 8 7/32 165 0.74 1.25 0.57 10 Sol. - 2 Sol. 6 (6-1) 4 (7-1) 10 Sol. - 2 Sol. 6 (6-1) - 4 (7-1) 4 6 1/4 275 KSU23 0.81 1.48 0.59 8 Str. - 2 Str. 3 (6-1) 2 (6-1) 8 Sol. - 2 Str. 6 (6-1) - 2 (6-1) — 4 5/16 275 KSU25 0.93 1.77 0.70 2 Str. - 1/0 Str. 3 (6-1) 1 (6-1) 10 Str. - 1/0 Str. 6 (6-1) - 1 (6-1) — — 3/8 385 KSU26 1.04 1.93 0.79 2 Str.-2/0 Str. 1 (6-1) 1/0 (6-1) 8 Str. - 2/0 Str. 6 (6-1) - 1/0 (6-1) — — 7/16 385 KSU27 1.38 2.34 1.12 1 Str. - 3/0 Str. 1 (6-1) 2/0 (6-1) 8 Sol. - 3/0 Str. 8 (6-1) - 2/0 (6-1) — — 1/2 500 KSU29 1.38 2.50 1.58 1Str. -250 kcmil 2/0 (6-1) 4/0 (6-1) 8 Str. - 250 6 (6-1) - 4/0 (6-1) — — 1/2 650 KSU31 1.69 2.88 1.36 1/0 Str. 350 kcmil 3/0 (6-1) 4/0 (6-1) 4 Str. - 350 4 (6-1) - 4/0 (6-1) — — 5/8 650 KSU34 2.00 3.12 1.47 400 - 500 kcmil 336 (30-7) 477 (18-1) 2 Str. - 500 2 (6-1) - 477 (18-1) — — — 825 Accommodates compressed conductors within conductor ranges. See note LIGHTNING PROTECTION INFO. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE KSA A-5 TRITAP™ SERVIT® For All Combinations of Aluminum to Aluminum, Aluminum to Copper and Copper to Copper, Aluminum Alloy Tin Plated PATENTED TRIANGULAR PENETRATION TECHNOLOGY CONTACT Catalog Number Cross Flats L W KSA6 0.75 1.58 KSA4 0.81 KSA2 Features & Benefits • No scratch brushing required. • No oxide inhibitor required. • Orients the conductor. • Provides maximum pressure and assures a secure connection of run and tap conductors. • Facilitates piercing the aluminum conductor surface oxides. • UL 486B listed, 90°C rated. • Provides a low contact resistance. • Provides equal coefficient of expansion • Inhibits the reformation of oxides by producing a gas-tight seal. • Provides improved retention of minimum to maximum conductor combinations. Alum. to Alum., Alum. to Copper, Copper to Copper Conductors Recommended ▲ Tightening Torque (in-lb) Max Run to Max Tap Min Run to Min Tap Max Run to Min Tap 0.56 #6 Str. (0.184) #6 Str. (0.184) #10 Sol. (0.102) #10 Sol. (0.102) #6 Str. (0.184) #10 Sol. (0.102) 165 1.38 0.62 #4 Str. (0.232) #4 Str. (0.232) #8 Sol. (0.129) #10 Sol. (0.102) #4 Str. (0.232) #10 Sol. (0.102) 165 0.94 1.58 0.69 #2 Str. (0.292) #2 Str. (0.292) #6 Sol. (0.169) #8 Str. (0.146) #2 Str. (0.292) #8 Sol. (0.146) 275 KSA1/0 1.00 1.92 0.75 #1/0 Str. (0.373) #1/0 Str. (0.373) #2 Str. Compact (0.268) #8 Sol. (0.129) #1/0 Str. (0.373) #8 Sol. (0.129) 385 KSA2/0 1.12 1.92 0.88 #2/0 Str. (0.418) #2/0 Str. (0.418) #2 Str. Compact (0.268) #8 Str. (0.146) #2/0 Str. (0.418) #8 Str. (0.146) 385 KSA4/0 1.49 2.54 1.13 #4/0 Str. (0.528) #4/0 Str. (0.528) #2 Str. Compact (0.268) $6 Str. (0.184) #4/0 Str. (0.528) $6 Str. (0.184) 500 KSA350 1.69 3.24 1.50 350 kcmil (0.681) 350 kcmil (0.681) #1/0 Str. Compact (0.336) #4 Str. (0.232) 350 kcmil (0.681) #4 Str. (0.232) 650 KSA500 2.00 3.62 1.73 500 kcmil (0.813) 500 kcmil (0.813) 400 kcmil Compact (0.659) #2 Str. Compact (0.268) 500 kcmil (0.813) #2 Str. Compact (0.268) 825 ▲ Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor combinations. ** No scratch brushing or oxide inhibiting compounds required for insulated 90° C max. rated conductor for N.E.C. applications. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-6 BURNDY® TYPE KVS OKLIP™ Copper & Copperweld Compact, two-piece, high strength, high copper alloy BURNDY® OKLIP™ recommended for heavy duty connections. Neoprene rings hold DURIUM™ bolts in place during installation. Installed with ordinary wrench. Conductor Catalog Number Copperweld Max Run & Tap Str. 7 #8 7 #6 19 #8 19 #6 19 #5 — Copper Run 2 Str. - 2/0 Str. 1/0 Str. - 4/0 Str. 250 - 350 kcmil 400 - 500 kcmil 400- 800 kcmil 500 - 1000 kcmil KVS26 KVS28 KVS31 KVS34 KVS40 KVS44 Tap 6 Str. - 2/0 Str. 10 Str. - 4/0 Str. 10 Str. - 350 kcmil 10 Str. - 500 kcmil 3/0 Str. - 800 kcmil 3/0 Str. - 1000 kcmil Sol. 3/0 4/0 — — — — ▲ Recommended Tightening Torque (in-lb) Type V — V3/0 V250 V350 — — 180 250 325 375 500 500 ▲ Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor combinations. See note LIGHTNING PROTECTION INFO. TYPE KVSU UNIVERSAL OKLIP™ Mechanical Connector All Combinations of Copper, Aluminum, ACSR, AAAC & 5005 Compact, high strength, tin plated copper alloy twopiece connector with spacer and tin-plated silicon bronze DURIUM™ hardware. Recommended for heavy duty connections. Spacer separates dissimilar conductors and provides long contact length. Neoprene ring prevents loss of shorter bolt during installation. Longer peened bolt permits swivel action for easier installation. Use of PENETROX™ joint compound recommended with aluminum and ACSR. Conductor Catalog Number Run Tap Run Tap Steel Nom. Dia. J L W Rec. Tightening Torque (in-lb) Copper & Alum ACSR, AAAC, & 5005 Copper & Alum ACSR, AAAC, & 5005 KVSU26 2 Str. - 2/0 Str. 3 - 2/0 6 Str. - 2/0 Str. 6 - 2/0 1 - 3/0 5/16 7/16 #6 - 3/0 3/16 7/16 2 5/16 1 1-1/2 180 KVSU28 1/0 Str. - 4/0 Str. 1/0 - 4/0 6 Str. - 4/0 Str. 6 - 4/0 2/0 - 4/0 3/8 - 1/2 #6 - 4/0 5/32 - 1/2 2-3/8 3/8 1-1/8 1-3/4 250 KVSU31 250 - 350 kcmil 4/0 - 300 #6 - 350 6 - 300 - 9/16 - 5/8 #6 - 4/0 3/16 - 5/8 2-5/8 1/2 1-3/8 2-1/8 325 KVSU34 400 - 500 kcmil 336.4 - 397.5 #4 - 500 5 - 397.5 - 3/4 - 3/4 #4 - 4/0 7/32 - 3/4 3 1/2 1-1/2 2-1/4 375 KVSU40 400 - 800 kcmil 4/0 - 800 4/0 - 800 3/0 - 715.5 - 3/4 - 1 - 1/2 - 1 3-1/2 1/2 1-5/8 2-1/2 500 KVSU44 500 - 1000 kcmil 4/0 - 1000 4/0 - 1000 kcmil 4/0 - 900 - 7/8 - 1 1/8 - 1/2 - 1 1/8 4 3/8 2 3 500 Accomodates compressed conductors within diameter range. Steel Nom. Dia. Copper Sol., Copperweld Sol. H Copper Sol., Copperweld Sol. See note LIGHTNING PROTECTION INFO. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE KVSW A-7 OKLIP™ Mechanical Connector For Copper and Copperweld Similiar to OKLIP™ Type KVS except for a high copper alloy spacer that separates run and tap conductors. Provides high contact pressure, confines conductor strands, and assures vibrationproof connection. Longer peened bolt, permits swivel action for easier installation. Silicon bronze DURIUM™ hardware. Catalog Number KVSW26 KVSW28 KVSW31 KVSW34 KVSW40 KVSW44 Conductor Run 2 Str. - 2/0 Str. 1/0 Str. - 4/0 Str. 250 - 350 kcmil 400 - 500 kcmil 400 - 800 kcmil 500 - 1000 kcmil Recommended Tightening Torque (in-lb) 180 250 325 375 500 500 Tap 6 Sol. - 2/0 Str. 6 Sol. - 4/0 Str. 4 Sol. - 350 kcmil 4 Str. - 500 kcmil AWG 4/0 - 800 kcmil 250 - 1000 kcmil See note LIGHTNING PROTECTION INFO. TYPE KVS-A ALUMINUM OKLIP™ For Use On All Combinations of Copper, Aluminum†, ACSR†, AAAC and 5005 Three-piece, high-conductivity, non-copper bearing aluminum alloy connector with thick spacer and aluminum hardware. Hardware in KVS26A and KVS28A is stainless steel. Recommended for heavy duty dissimilar metal applications. Spacer separates conductors and provides long contact length. Belled entrances prevent chafing, permit easier assembly of conductors. Longer peened bolt permits swivel action for easier installation. Neoprene ring prevents loss of shorter bolt. PENETROX™ joint compound recommended with aluminum and ACSR. Run Copper, & Alum.† ACSR†, AAAC, & 5005 Tap Copper, & Alum.† ACSR†, AAAC & 5005 #4 - 2/0 10 Str. - 2/0 Str. #6 - 2/0 KVS26A 2 Str. - 2/ 0 Str. 1/0 - 4/0 10 Str. - 4/0 Str. #6 - 4/0 KVS28A 1/0 Str. - 4/0 Str. 250 - 350 4/0 - 336.4 6 Str. - 350 kcmil #6 - 336.4 kcmil KVS31A 400 - 500 336.4 - 397.5 4 Str. - 500 kcmil #5 -397.5 kcmil KVS34A 400 - 800 336.4 - 715.5 kcmil 3/0 Str. - 800 kcmil #3/0 - 715.5 KVS40A 500 - 1000 397.5 - 900 kcmil 3/0 Str. - 1000 kcmil #3/0 - 900 kcmil KVS44A † Accommodates compressed conductors within diameter range. APPLICATION OVER ARMOR ROD Conductor Range by Diameter Conductor Catalog Number THESE CONNECTORS CAN ACCOMMODATE ACSR CONDUCTORS OVER ARMOR ROD WITHIN THE DIAMETER RANGE INDICATED. Rec. Tightening Torque (in-lb) Min. Run Dia. Min. Tap Dia. Max. Run & Tap Dia. H J L W 180 0.28 0.12 0.45 2-1/4 5/16 1-1/4 1-5/8 1-5/8 2-1/16 240 0.36 0.12 0.56 3 3/8 300 0.57 0.18 0.68 3-1/16 1/2 1-15/16 2-7/16 300 0.73 0.22 0.81 3-9/16 1/2 2-5/16 2-5/8 300 0.73 0.47 1.04 4-1/16 1/2 2-7/16 2-7/8 480 0.80 0.47 1.16 4-7/8 5/8 2-1/2 3-1/8 See note LIGHTNING PROTECTION INFO. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-8 BURNDY® TYPE QPX VERSITAP™ Parallel Clamp For Copper, Copperweld, Copperweld-Copper The VERSITAP™ Type QPX is recommended for Tee, Cross, Parallel, Butt and Tap connections. Rangetaking, only 10 connectors required to accommodate conductor sizes from #6 Str. to 1000 kcmil. Edges are rounded for easy taping. Made of high strength, high-conductivity copper alloy and silicon bronze DURIUM™ hardware. * For various configurations, see page TYPE QPX-Y Fig. 1 Fig. 2 Copper Conductor Dimensions Catalog Number Run Tap QPX2C2C 6 Str. - 2 Str. 6 Str. - 2 Str. 1-1/2 QPX282C 1 Str. - 4/0 Str. 6 Str. - 2 Str. 2-1/16 QPX2828 1 Str. - 4/0 Str. 1 Str. - 4/0 Str. QPX342C 250 - 500 kcmil 6 Str. - 2 Str. QPX3428 250 - 500 kcmil 1 Str. - 4/0 Str. QPX3434 250 - 500 kcmil 250 - 500 kcmil QPX442C QPX4428 QPX4434 QPX4444 500 - 1000 kcmil 500 - 1000 kcmil 500 - 1000 kcmil 500 - 1000 kcmil 6 Str. - 2 Str. 1 Str. - 4/0 Str. 250 - 500 kcmil 500 - 1000 kcmil Fig. No. 1 H 2-3/8 2-3/4 2 1 2 3 J L 5/16 1-5/16 3/8 1-13/16 1-13/16 5/16 3/8 2-11/16 5/16 2-7/8 3-1/16 3-7/16 ▲ Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor combinations. 1-3/8 1-9/16 150 5 Sol. - 3 #7 8A - 4A 250 7 #9 - 7 #5 3A - 3/0V 5 Sol. - 3 #7 8A - 4A 7 #9 - 7 #5 3A - 3/0V 5 Sol. - 3 #7 8A - 4A 7 #9 - 7 #5 3A - 3/0 V 1-3/8 1-7/8 1-3/4 2-1/16 2-1/16 2-3/16 19 #19 - 19 #6 4/0 EK 1-3/8 2-1/4 5 Sol. - 3 #7 8A - 4A 7 #9 - 7 #5 3A - 3/0V 19 #19 - 19 #6 4/0 EK 19 #6 — 1-13/16 3/8 W Conductor Rec. Tightening Run Tap Torque Copperweld Copperweld in-lb ▲ Copperweld Copperweld - Copper - Copper 2-1/16 2-5/8 2-7/16 375 19 #19 - 19 #6 500 19 #6 2-9/16 4/0 EK — See note LIGHTNING PROTECTION INFO. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE QPX-Y A-9 UNIVERSAL VERSITAP™ Universal Parallel Clamp For Copper and Aluminum High copper alloy cast connector, tin-plated for use with copper or aluminum cable. Makes parallel, tap, tee, cross or end-to-end connections. Edges rounded for easy taping. PENETROX™ joint compound recommended. Fig. 1 Catalog Number QPX2C2C-Y Fig. 2 H J L W Recommended Tightening Torque in-lb ▲ 150 Run Tap Fig. No. 6 Str.-2 Str. 6 Str.-2 Str. 1 1-5/8 5/16 1-1/2 1-5/8 QPX282C-Y 1 Str. - 4/0 Str. 6 Str.-2 Str. 1 1-7/8 5/16 1-1/2 1-7/8 150 QPX2828-Y 1 Str. - 4/0 Str. 1 Str. - 4/0 Str. 1 2 3/8 2 2-1/8 250 QPX342C-Y 250 - 500 kcmil 6 Str.-2 Str. 1 2-1/4 5/16 1-1/2 2-1/8 375 QPX3428-Y 250 - 500 kcmil 1 Str. - 4/0 Str. 1 2-1/2 3/8 2 2-1/2 375 QPX3434-Y 250 - 500 kcmil 200 - 500 kcmil 2 2-7/8 3/8 2-1/2 2-5/8 375 QPX4444-Y 750 - 1000 kcmil 750 - 1000 kcmil 2 3-7/8 1/2 3-1/2 3-1/2 500 ▲ Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5 7-6 for smaller conductor combinations. See note LIGHTNING PROTECTION INFO. APPLICATION VARIATIONS PARALLEL TAP CROSS TEE SPLICE Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-10 BURNDY® TYPE KPA SCRULUG™ For Copper Cable High copper alloy tin-plated terminal for joining a wide range of cable to equipment pads or terminal blocks. Especially good in light industrial applications. The tongue and body are a one-piece design. The pressure bar equalizes pressure over the conductor and prevents the screw from cutting into the cable. Fig. 1 Wire Range Fig. No. C KPA8C 14 Sol. - 8 Str. 1 0.38 0.47 KPA4C 14 Sol. - 4 Str. 1 0.50 0.59 KPA25 4 Str. - 1/0 Str. 2 0.75 0.81 KPA28 1/0 Str. - 4/0 Str. 2 0.97 1.12 KPA34 4/0 Str. - 500 kcmil 2 1.38 1.38 Catalog Number Fig. 2 K Stud Hole Size 0.72 0.21 0.94 0.27 1.25 0.33 5/16 1.66 0.39 3/8 2.44 0.54 1/2 3.32 D H Recommended Tightening Torque (in-lb) L N T #10 0.97 0.22 0.06 25 1/4 1.22 0.30 0.06 35 1.82 0.41 0.10 180 2.40 0.53 0.13 250 0.75 0.20 375 NOTE: For unplated version add “UNPL” suffix. TYPE KPA-UP SCRULUG™ For Copper Cable High copper alloy terminal for joining a wide range of cable to equipment pads or terminal blocks. Plain copper finish. Fig. 1 Features & Benefits • High conductivity copper alloy. ◊ Long lasting, reliable contact. • Compact design. ◊ Easy to use. • Slot Robertson screw, hex head, hex socket bolt. ◊ No special installation tools required. Eliminates over-torquing/potential conductor damage. • One piece design. ◊ Superior torque and pull out performance. • Convenient range taking design. ◊ Reduces catalog numbers. One catalog number accommodates several conductor sizes. Catalog Number Wire Range KPA8CUP 14 Sol. - 6 Str. KPA4CUP 14 Sol. - 4 Str. Fig. No. 1 C D H K Stud Hole Size 0.38 0.56 0.81 0.20 #10 1.04 0.22 0.50 0.71 1.00 0.28 1/4 1.28 0.33 NOTE: For tin plating drop “-UP” suffix and add “-TP” suffix (example: KPA4CTP). L N T 0.07 Hardware Recommended Tightening Torque (in-lb) # 12-24 SLOT 35 5/16 DIA.SLOT ROBERTSON 45 For use in grounding applications with a green screw, contact factory. Listed for grounding per UL467. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE KLU A-11 SCRULUG™ FOR COPPER CABLE OFFSET TONGUE - NON-PLATED High copper alloy terminal with offset tongue for joining a wide range of cable to equipment pads or bar. Easy to install with screwdriver or wrench. Connector is reusable. Plain copper finish. Features & Benefits • Convenient range-taking design. ◊ Reduces catalog numbers. One conductor accommodates several conductor sizes. • High conductivity copper alloy ◊ Long lasting reliable contact. 1 Catalog Number KLU25 KLU25TP KLU35 KLU35TP KLU70 KLU70TP KLU125 KLU125TP KLU175 KLU175TP KLU225 KLU225TP KLU300 KLU300TP KLU400 KLU400TP • Compact design ◊ Easy to use. Reduces labor time. • Slot Robertson screw, hex head/hex socket bolt ◊ No special installation tools required. eliminates over-torquing/potential conductor damage. Rec. Tightening Torque (in-lb) Stud Hole Size Strip Length (in) No. 8-32 Slotted Round Machine Screw #6 7/16 35 1/4 UNF Slotted Set Screw #10 5/8 2.00 0.08 40 5/16 UNF Slotted Set Screw 1/4 3/4 11.0 0.42 3.00 0.11 50 3/8 UNF Slotted Set Screw 1/4 15/16 56.0 2.20 11.0 0.43 4.00 0.16 250 3/8 UNF Socket/Hex Screw 3/8 1 9.00 0.34 65.0 2.55 13.0 0.51 3.00 0.12 250 7/16 UNF Socket/Hex Screw 5/16 1-5/16 25.0 0.99 10.0 0.39 72.0 2.83 13.0 0.52 3.00 0.12 325 5/8 UNF Socket/Hex Screw 3/8 1-5/8 38.0 1.50 10.0 0.39 104.0 4.09 23.0 0.91 5.00 0.18 375 5/8 UNF Socket/Hex Screw 3/8 1-5/32 Fig. No. B (MM/IN) C (MM/IN) K (MM/IN) L (MM/IN) N (MM/IN) T (MM/IN) 14 Sol. .064 Dia.to 10 Sol. .102 Dia. CU 3 7.00 0.28 8.00 0.31 4.00 0.14 26.0 1.02 5.00 0.21 2.00 0.07 20 14 Sol. .0641 Dia.to 6 Str. .184 Dia. CU 2 11.0 0.43 10.0 0.39 5.00 0.20 31.0 1.24 6.00 0.22 2.00 0.07 8 Sol. .129 Dia. to 2 Str. .292 Dia. CU 2 13.0 0.50 12.0 0.47 7.00 0.26 39.0 1.55 6.00 0.25 2 Str. .292 Dia. to 1/0 Str. .372 Dia. CU 2 15.0 0.61 16.0 0.62 7.00 0.26 50.0 1.98 4 Str. .232 Dia. to 3/0 Str. .470 Dia. CU 1 18.0 0.72 19.0 0.75 10.0 0.39 2 Str. .292 Dia. to 4/0 Str. .528 Dia. CU 1 24.0 0.94 25.0 0.99 1/0 Str. .372 Dia. to 350 kcmil .681 Dia. CU 1 31.0 1.22 1/0 Str. .372 Dia. to 500 kcmil .813 Dia. CU 1 36.0 1.42 Conductor Hardware NOTES: 1 Suffix “-TP” on catalog number denotes tin plate (example: KLU400TP). 2 Material: Copper alloy. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-12 BURNDY® TYPE KA KA-LUG™ For Copper Cable Compact, economical, high copper alloy terminal for joining a wide range of cable to equipment pads or terminal blocks. Fig. 1 Catalog Number Conductor KA4C KA25 KA25-2TC38 KA28 KA34 Fig. 3 Fig. No. C H J K Stud Hole Size L N T Recommended Tightening Torque (in-lb) 1 3/8 5/8 #12 7/32 #10 13/16 3/16 3/32 25 1 9/16 3/4 5/16" 9/32 1/4 1-1/8 1/4 7/64 45 2 3/4 15/16 1/2" 27/64 3/8 1-11/16 3/8 1/8 200 3 3/4 15/16 1/2" 27/64 3/8 2-13/16 3/8 1/8 200 2 15/16 1-1/4 5/8" 27/64 3/8 1-15/16 7/16 3/16 275 2 1-3/8 2-3/32 13 /16" 9/16 1/2 2-9/16 9/16 9/32 375 # 14 Sol. (0.064 Dia.) 8 Str. (0.416 Dia.) # 14 Sol. (0.064 Dia.) 4 Str. (0.232 Dia.) # 4 Str. (0.232 Dia.) 1/0 Str. (0.373 Dia.) # 4 Str. (0.232 Dia.) 1/0 Str. (0.373 Dia.) # 1 Str. (0.332 Dia.) 4/0 Str. (0.528 Dia.) 4/0 Str. (0.528 Dia.) 500 kcmil (0.814 Dia.) KA8C Fig. 2 ▲ Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. TYPE EA VERSILUG™ For Copper Cable Compact, high copper alloy terminal for joining a wide range of cable to equipment pads or bar. Clamping element adjustable to several angles. One-wrench installation. Catalog Number Wire Range EA2C EA25 EA28 EA28-2N EA34 EA34-2N 8 AWG-2 AWG 2 AWG-1/0 1/0 -4/0 AWG 1/0 -4/0 AWG 250 kcmil-500 kcmil 250 kcmil-500 kcmil No. of holes in pad 1 1 1 2 1 2 * “N” indicates NEMA standard stud holes. ▲ Listed torque values are for maximum conductor sizes accommodated. C D E H K 13/16 7/8 1-1/16 1-1/16 1-3/8 1-3/8 1-1/16 1-1/8 1-3/8 3-5/8 1-5/8 3-5/8 — — — 1-3/4 — 1-3/4 1-3/8 1-7/16 1-3/4 1-3/4 2-1/4 2-1/4 7/16 7/16 7/16 9/16 9/16 9/16 Stud Hole Size 3/8 3/8 3/8 1/2 1/2 1/2 L N T 2-1/2 2-11/16 3-3/16 5-1/8 4 5-5/8 13/32 7/16 17/32 5/8 13/16 5/8 1/4 1/4 5/16 5/16 3/8 3/8 Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. Rec. Tightening Torque (in-lb) 150 180 250 250 375 375 Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE BGBL A-13 LAY-IN QIKLUG™ UL LISTED 90° C, 600 V The Lay-In QIKLUG™, Type BGBL is manufactured from high strength 6061-T6 aluminum, and is ideally suited for grounding and bonding applications accommodating both copper and aluminum conductor sizes #14 AWG to 250 kcmil. The BGBL4SS with Stainless Steel screw is UL 467 Listed for grounding and bonding. H REF N Features & Benefits T • UL 486B listed, AL9CU rated ◊ For copper and aluminum conductor combinations up to 90° C, 600 Volt applications. • UL Recognized for grounding and bonding ◊ Ensures reliability. • Electro-tin plated ◊ Provides low contact resistance. • Lay-in feature ◊ Eases installation. L C K DIA. J Conductor Range C H J K L N T Hex Size BGBL-4 14 - 4 0.38 [10] 0.78 [20] 1/4 - 28 0.22 [6] 1.07 [27] 0.19 [5] 0.15 [4] Slot BGBL4SS* 14 - 4 0.38 [10] 0.78 [20] 1/4 - 28 0.22 [6] 1.07 [27] 0.19 [5] 0.15 [4] Slot BGBL-1/0 14 - 1/0 0.60 [15] 1.17 [30] 3/8 - 24 0.27 [7] 1.50 [38] 0.30 [8] 0.22 [6] Slot BGBL-250 6 - 250 kcmil 0.80 [20] 1.79 [45] 9/16 - 18 0.33 [8] 2.20 [56] 0.40 [10] 0.30 [8] 5/16 Catalog Number * Suitable for copper conductors only. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-14 BURNDY® TYPE CL50-1 & CL50-1TN COPPER LAY-IN QIKLUG™ For Copper The Lay-In QIKLUG™ is manufactured from high strength pure electrolytic copper to ensure maximum strength and conductivity. UL467 Listed for direct burial in earth or concrete. The open-faced design allows for fast lay-in of the conductor without the need for cutting or breaking. Stainless steel screws used for excellent corrosion resistance. Catalog Number Conductor Range Stud Hole CL50-1 14 AWG-4 AWG #10 CL50-1TN 14 AWG-4 AWG #10 Photo above shows a typical solar panel installation using CL50-1 connectors. TYPE CL COPPER LAY-IN QIKLUG™ For Copper Manufactured for maximum strength and conductivity, these lay-in lugs allow for continuous runs of conductor and are well suited as terminations as well. Tin-plated, set screw style connectors, three sizes cover a range from #14AWG to 250 kcmil. CL3/0-516TN and CL250516TN are UL Listed and CSA certified. CL1/014TN UL Listed for grounding and CSA certified. 90° C rated. Suitable for copper conductors only. Catalog Number Wire Range Copper H W L T K Dia Hex Size CL1/0-14TN #14 - 1/0 AWG 1.17 0.60 1.50 0.22 0.27 7/16-20 (Slotted) CL3/0-516TN #6 - 3/0 AWG 1.56 0.80 2.00 0.30 0.33 9/16-18 (0.25 Hex) CL250-516TN #6 AWG - 250 kcmil 1.79 0.80 2.20 0.30 0.33 9/16-18 (0.25 Hex) Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPES QA, QQA A-15 QIKLUG™ Copper Cable Type QA heavy duty, compact, high copper alloy terminal for joining a wide range of cable to equipment pads or bar. Fast one-wrench installation. Type QQA heavy duty, high copper alloy terminal for joining cable to equipment pads or bar. Twin clamping elements secure joint vibration and flexing. One-wrench installation. Type QA Catalog Number* Type QA QA8C-B QA8C-2B QA4C-B QA4C-2B QA1C-B QA1C-2B QA26-B QA26-2B QA28-B QA28-2B QA28-2N* QA31-B QA31-2B QA31-2N QA34-B QA34-2B QA34-4B QA34-2N* QA40-B QA40-2N* QQA40-4N* QA44-B QA44-2N* QA44-4N* QA46-2N* QA46-B Type QQA Conductor Commercial 14 Sol. - 8 Str. QQA8C 14 Sol. - 8 Str. QQA8C-2 8 Str. - 4 Str. QQA4C 8 Str. - 4 Str. QQA4C-2 4 Str. - 1 Str. QQA1C 4 Str. - 1 Str. QQA1C-2 1/0 Str. - 2/0 Str. QQA26 1/0 Str. - 2/0 Str. QQA26-2 3/0 Str. - 4/0 Str. QQA28 3/0 Str. - 4/0 Str. — QQA28-2N* 3/0 Str. - 4/0 Str. 250 - 350 kcmil QQA31 250 - 350 kcmil — QQA31-2N* 250 - 350 kcmil 400 - 500 kcmil — 400 - 500 kcmil — 400 - 500 kcmil QQA34 QQA34-2N* 400 - 500 kcmil 600 - 800 kcmi — QQA40-2N* 600 - 800 kcmi 600 - 800 kcmi — 850 - 1000 kcmil — QQA44-2N* 850 - 1000 kcmil QQA44-4N* 850 - 1000 kcmil 1100 - 1500 kcmil — 1100 - 1500 kcmil — Type QQA Navy Holes in Pad C D E&F H K Stud Hole Size L LL N T Torque (in-lb) 4-14 1 9/16 9/16 — 11/16 7/32 #10 1-3/8 2-5/16 9/32 5/32 75 4-14 2 9/16 1-1/14 5/8 11/16 7/32 #10 2 3 5/16 5/32 75 23-40 1 5/8 5/8 — 3/4 9/32 1/4 1-7/16 2-3/8 5/16 3/16 110 23-40 2 5/8 1-3/16 5/8 3/4 9/32 1/4 2 2-15/16 5/16 3/16 110 50-75 1 5/8 3/4 — 1 9/32 1/4 1-3/4 2-13/16 11/32 7/32 150 50-75 2 5/8 1-9/16 7/8 1 11/32 5/16 2-9/16 3-5/8 11/32 7/32 150 100-125 1 13/16 1 — 1-3/16 13/32 3/8 2 3-3/16 7/16 7/32 180 100-125 2 13/16 1-15/16 1 1-3/16 13/32 3/8 3 4-3/16 7/16 7/32 180 150-200 1 1 1-1/16 — 1-5/16 13/32 3/8 2-1/4 3-9/16 17/32 1/4 250 — 2 1 2 1 1-9/29 13/32 3/8 3-1/5 — 7/16 1/4 250 150-200 2 1 3-1/8 1-3/4 1-5/16 9/16 1/2 4-5/16 5-5/8 5/8 1/4 250 250-350 1 1-3/16 1-3/8 — 1-11/16 17/32 1/2 2-11/36 4-1/8 11/16 5/16 325 250-350 2 1-3/16 1-31/32 1 1-11/16 7/16 3/8 3-3/8 — 7/16 5/16 325 5/8 5/16 325 250-350 2 1-3/16 3 1-3/4 1-11/16 9/16 1/2 4-7/16 5-7/8 400-500 1 1-3/8 1-5/8 — 2 17/32 1/2 3-3/16 4-7/8 400-500 2 1-3/8 2 1 2 13/32 3/8 3-9/16 400-500 4 1-7/8 1-15/16 1 2 7/16 3/8 400-500 2 1-3/8 3-3/32 1-3/4 2 9/16 1/2 650-800 1 1-5/8 1-7/8 — 2-7/16 11/16 5/8 650-800 2 1-5/8 3 1-3/4 2-7/16 9/16 650-800 4 3 3 1-3/4 2-7/16 9/16 1000 1 1-7/8 2 — 2-3/4 1000 2 1-7/8 3 1-3/4 2-3/4 13/16 5/16 375 — 7/16 375 3-1/2 — 7/16 5/16 375 4-11/16 6-9/32 5/8 5/16 375 3-11/16 — 27/32 3/8 500 1/2 4-14/16 7-3/32 5/8 3/8 500 1/2 — 7-3/32 5/8 3/8 500 11/16 5/8 3-15/16 — 1 1/2 500 9/16 1/2 5 7-1/8 5/8 1/2 500 5/16 1000 4 3 3-1/16 1-3/4 2-3/4 9/16 1/2 5 7-1/8 5/8 1/2 500 1300 2 2-1/8 3 1-3/4 3-1/8 9/16 1/2 5-1/4 — 5/8 9/16 600 1300 1 2-1/8 2-1/8 — 3-1/8 13/16 3/4 4-3/8 — 1-1/16 9/16 600 * ‘‘N’’ indicates NEMA standard stud holes. All 4N items see note LIGHTNING PROTECTION INFO. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-16 BURNDY® TYPE Q2A QIKLUG™ For Copper Cable Compact, high copper alloy terminal for joining two cables to equipment pads or bars. Each element accommodates a wide range of cable. Onewrench installation. Catalog Number* Q2A1C-2 Q2A26-2N Q2A28-2N Q2A28-4N Q2A31-2N Q2A31-4N Q2A34-2N Q2A34-4N Q2A40-2N Q2A40-4N Q2A44-4N Q2A46-4N Conductor 4 Str. - 1 Str. 1/0 Str. - 2/0 Str. 3/0 Str. - 4/0 Str. 250 - 350 kcmil 400 - 500 kcmil 600 - 800 kcmil 850 - 1000 kcmil 1100 - 1500 kcmil No. of Holes in Pad 2 4 2 4 2 4 2 4 C D E&F H K 1-1/2 1-5/8 1-7/8 3 2-3/8 3 2-1/2 1-7/8 1 3/4 1-1/16 1-3/16 7/16 Stud Hole Size 3/8 1-3/8 N 2-7/8 4-3/16 4-3/8 7/16 1-3/4 3 3-1/4 3-1/2 3-1/4 9/16 2 T 1/2 W 1-13/16 7/32 1-15/16 1/4 4-1/2 1-11/16 3-1/8 * ‘‘N’’ indicates NEMA standard stud holes. L 2-1/8 5/16 5/8 4-11/16 3 3/8 3-3/4 2-7/16 5 7/16 2-3/4 3-1/8 5-1/4 5-1/2 1/2 11/16 4-11/32 5 Recommended Tightening Torque in-lb 150 180 250 325 375 500 600 All 4N items see note LIGHTNING PROTECTION INFO. TYPE Q3A QIKLUG™ For Copper Cable Compact, high copper alloy terminal for joining three cables to equipment pads or bar. Each element accommodates a wide range of cable. One-wrench installation. Catalog Number* Q3A28-2N Q3A28-4N Q3A31-2N Q3A31-4N Q3A34-2N Q3A34-4N Q3A40-4N Q3A44-4N Q3A46-4N Conductor 3/0 Str. - 4/0 Str. 3/0 - 4/0 Str. 250 - 350 kcmil 400 - 500 kcmil 600 - 800 kcmil 850 - 1000 kcmil 1100 - 1500 kcmil No. of Holes in Pad 2 4 2 4 2 4 C 1-7/8 3 2-3/8 3 2-1/2 D 3-1/8 3 3-1/4 3-1/2 3-1/4 E&F 1-3/4 H K Stud Hole Size L N T W Recommended Tightening Torque in lb 1-3/8 4-5/16 4-3/8 1/4 3-3/16 250 1-11/16 4-7/16 5/16 4-1/16 325 3/8 4-9/16 375 7/16 1/2 11/16 5-13/16 6-5/8 7-7/8 1-15/16 9/16 1/2 2-7/16 2-3/4 3-1/8 4-3/4 5 5-1/4 5-1/2 5/8 500 600 * ‘‘N’’ indicates NEMA standard stud holes. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE QB A-17 QIKLUG™ For Copper Cable Compact, high copper alloy side entrance terminal for joining a range of cable at right angles to terminal blocks. One-wrench installation. Catalog Number* Conductor No. of Holes in Pad C D E H K Stud Hole Size L N T Recommended Tightening Torque in-lb QB8C 14 Sol. - 8 Str. 1 9/16 9/16 — 7/8 7/32 #10 1-1/8 9/32 5/32 75 QB4C 8 Str. - 4 Str. 1 11/16 27/32 — 13/16 9/32 1/4 1-3/8 11/32 1/4 110 QB1C 4 Str. - 1 Str. 1 11/16 13/16 — 1 9/32 1/4 1-1/2 11/32 7/32 150 QB26 1/0 Str. - 2/0 Str. 1 13/16 1 — 1-1/32 13/32 3/8 1-13/16 7/16 7/32 180 QB28 3/0 Str. - 4/0 Str. 1 1 1-1/16 — 1-5/16 13/32 3/8 2-1/16 17/32 1/4 250 QB31-2N 250 - 350 kcmil 2 13/16 3-1/4 1-3/4 1-11/16 9/16 1/2 4-1/2 5/8 5/16 325 * ‘‘N’’ indicates NEMA standard stud holes. TYPE Q2B QIKLUG™ For Copper Cable Compact, high copper alloy terminal for joining two cables at right angles to a single terminal block. Each element accommodates a range of cable. One-wrench installation. No. of Holes in Pad Stud Hole Size L 9/16 1/2 5-3/16 9/16 9/16 5-7/8 3/4 6-11/16 5/8 Catalog Number* Conductor Q2B28-2N 3/0 Str. - 4/0 Str. 2 1-7/8 3-1/8 1-3/4 1-3/8 Q2B31-2N 250 - 350 kcmil 2 2-3/8 3-3/16 1-11/16 1-3/8 Q2B40-4N 600 - 800 kcmil 4 3 3-1/16 1-3/8 2-5/16 9/16 C D * ‘‘N’’ indicates NEMA standard stud holes. E& F H K T Recommended Tightening Torque in-lb 5/8 1/4 250 5/8 5/16 325 7/16 500 N All 4N items see note LIGHTNING PROTECTION INFO. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-18 BURNDY® TYPE QDA QIKLUG™ For Copper Cable Compact, high copper alloy terminal for joining a wide range of cable to equipment studs. Provides low contact resistance when gripped between two contact nuts. One wrench installation. Conductor C H K Stud Hole Size L T Recommended Tightening Torque in-lb 3 - 14 1 11/16 7/16 3/8 1-7/8 3/16 75 8 Str. - 4 Str. 23 - 40 1 3/4 7/16 3/8 1-7/8 7/32 110 4 Str. - 1 Str. 50 - 75 1 1 7/16 3/8 2-3/16 9/32 150 QDA26 1/0 Str. - 2/0 Str. 100 - 125 1-1/4 1-3/16 9/16 1/2 2-1/2 5/16 180 QDA28 3/0 Str. - 4/0 Str. 150 - 200 1-1/4 1-5/16 9/16 1/2 2-5/8 5/16 250 QDA31 250 - 350 kcmil 250 - 350 1-1/2 1-11/16 11/16 5/8 3 5/16 325 QDA34 400 - 500 kcmil 400 - 500 1-7/8 2 13/16 3/4 3-5/8 5/16 375 QDA40 600 - 800 kcmil 650 - 800 2-1/8 2-5/16 1-1/16 1 4-3/16 3/8 500 Catalog Number Commercial Navy QDA8C 14 Sol. - 8 Str. QDA4C QDA1C TYPE QR QIKLINK™ SPLICE OR REDUCER For Copper Cable to Cable High copper alloy splicer/reducer for joining a range of cable end to end. Neat, compact easy to tape installation. One-wrench installation. Catalog Number Conductor Either Side H L W Recommended Tightening Torque in-lb QR4C 6 Sol. - 4 Str. 3/4 1-11/16 5/8 110 QR1C 4 Str. - 1 Str. 1-1/16 1-15/16 11/16 150 QR26 1/0 Str. - 2/0 Str. 1-3/16 2-1/8 13/16 180 QR28 3/0 Str. - 4/0 Str. 1-3/8 2-3/8 1 250 QR31 250 - 350 kcmil 1-11/16 2-5/8 1-1/4 325 QR34 400 - 500 kcmil 1-15/16 3-1/16 1-7/16 375 QR40 600 - 800 kcmil 2-7/16 3-5/8 1-7/8 500 See note LIGHTNING PROTECTION INFO. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE VT A-19 VARITAP™ T-CONNECTOR For Copper Cable to Cable High copper alloy T-connector for cable run, cable tap. V-bolt clamping elements accommodate large range of cable and are particularly suited for extra flexible cable. One-wrench installation. Conductor Catalog Number H L W Recommended Tightening Torque Run (A) Tap (AA) Run Tap VT2C2C 8 AWG-2 AWG 8 AWG-2 AWG 1-5/16 2-5/16 1-5/16 275 275 VT2525 6 AWG-1/0 6 AWG-1/0 1-5/8 2-5/8 1-7/16 385 385 VT2825 1/0 -4/0 AWG 6 AWG-1/0 1-5/8 3-1/8 1-1/4 250 385 VT2828 1/0 -4/0 AWG 1/0 -4/0 AWG 1-5/8 3-1/16 1-11/16 250 250 VT3025 1/0 -300 kcmil 6 AWG-1/0 1-7/8 3-3/8 1-3/8 325 385 VT3030 1/0 -300 kcmil 1/0 -300 kcmil 1-7/8 3-5/16 1-15/16 325 325 VT3425 300 kcmil-500 kcmil 6 AWG-1/0 3-11/32 3-11/16 1-1/2 375 385 VT3428 300 kcmil-500 kcmil 1/0 -4/0 AWG 3-11/32 3-1/2 1-11/16 375 250 VT3430 300 kcmil-500 kcmil 1/0 -300 kcmil 3-11/32 3-5/8 1-15/16 375 325 VT3434 300 kcmil-500 kcmil 300 kcmil-500 kcmil 3-11/32 3-3/4 2-1/4 375 375 VT4040 500 kcmil-800 kcmil 500 kcmil-800 kcmil 2-9/16 4-1/2 2-5/8 500 500 VT4425 750 kcmil-1000 kcmil 6 AWG-1/0 2-7/8 4-5/16 1-3/16 500 385 VT4428 750 kcmil-1000 kcmil 1/0 -4/0 AWG 2-7/8 4-1/8 1-11/16 500 250 VT4834 1500 kcmil-2000 kcmil 300 kcmil-500 kcmil 4-1/4 5-1/4 2-1/4 600 375 See note LIGHTNING PROTECTION INFO. TYPE E-C-G TRANSFORMER TAP ADAPTER For Copper Multi-tap, range-taking cast copper alloy connector designed to take 2, 3 or 4 conductors from a single secondary transformer outlet. Catalog Number Number of Conductors E2C34G1 2 E3C34G1 3 E4C34G1 4 Conductor Size A dia H J L W Recommended Tightening Torque 3-1/2 1/0 Sol. - 500 kcmil 0.78 2-7/8 1/2"-13 6-1/4 5-1/4 480 6-7/8 Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-20 BURNDY® TYPES VA, VVA VARILUG™ For Copper Cable High copper alloy terminal for joining a wide range of cable to equipment pads or bar. Particularly suitable for use on extra flexible cable. Onewrench installation. Type VVA, twin elements secure joint against vibration and flexing. Particularly recommended for use on extra flexible cables. One-wrench installation. Type VA Catalog Number* Type VA Type VVA VA2C VVA2C Type VVA Conductor No. of Holes in Pad C D E&F H K Stud Hole Size L LL N T Rec. Tightening Torque 8 AWG-2 AWG 1 13/16 1-1/4 — 1-1/2 7/16 3/8 2-3/4 4-1/16 13/32 1/4 275 VA25 VVA25 6 AWG-1/0 1 7/8 1-5/16 — 1-7/8 7/16 3/8 2-7/8 4-5/16 7/16 1/4 385 VA28 VVA28 1/0 -4/0 AWG 1 1-1/16 1-1/2 — 2-1/4 7/16 3/8 2-7/8 4-1/8 17/32 5/16 250 VA28-2N VVA28-2N 1/0 -4/0 AWG 2 1-1/16 3-1/2 1-3/4 2-1/4 9/16 1/2 4-15/16 6-1/5 5/8 5/16 250 VA30 VVA30 1/0 -300 kcmil 1 1-1/8 1-5/8 — 2-3/16 7/16 3/8 3-1/4 4-5/8 5/8 5/16 325 VA30-2N VVA30-2N 1/0 -300 kcmil 2 1-1/8 3-9/16 1-3/4 2-3/16 9/16 1/2 5-3/16 6-9/16 5/8 5/16 325 — VA34 VVA34 300 kcmil-500 kcmil 1 1-3/8 2 3-11/32 9/16 1/2 3-13/16 5-5/16 13/16 3/8 375 VA34-2N VVA34-2N 300 kcmil-500 kcmil 2 1-3/8 3-5/8 1-3/4 3-11/32 9/16 1/2 5-3/8 6-7/8 5/8 3/8 375 VA34-4N VVA34-4N 300 kcmil-500 kcmil 4 3 3-5/8 1-3/4 3-11/32 9/16 1/2 5-3/8 6-7/8 5/8 3/8 375 VA40 VVA40 500 kcmil-800 kcmil 1 1-5/8 2-5/16 — 2-7/8 11/16 5/8 4-1/2 6-3/8 15/16 3/8 500 VA40-2N VVA40-2N 500 kcmil-800 kcmil 2 1-5/8 3-5/8 1-3/4 2-7/8 9/16 1/2 5-13/16 7-11/16 5/8 3/8 500 VA40-4N VVA40-4N 500 kcmil-800 kcmil 4 3 2-5/8 1-3/4 2-7/8 9/16 1/2 5-13/16 7-11/16 5/8 3/8 500 * “N” indicates NEMA standard stud holes. All 4N items see note LIGHTNING PROTECTION INFO. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE HFB-P1 A-21 BAR CLAMP ASSEMBLY COMPONENTS For Copper Bar To build your own high strength clamp assembly for multiple flat bar using type HFB-P1 bar clamps and clamping hardware, the following tables have been provided. The clamp assembly eliminates the need for drilling the flat bar and is used in indoor and outdoor applications. One Clamp Half Bar Clamp Bar Tap ‘AA’ “J” Bolt Dia. L W Z Recommended Tightening Torque in-lb 2 2 3/8 4.38 4.38 * 240 Catalog Number Run ‘A’ HFB22P1 HFB33P1 3 3 3/8 4.38 4.38 * 240 HFB42P1 4 2 3/8 5.75 5.75 * 240 HFB44P1 4 4 1/2 5.75 5.75 * 480 HFB63P1 6 3 1/2 7.75 4.75 * 480 HFB66P1 6 6 5/8 8.12 8.12 * 660 HFB88P1 8 8 3/4 10.50 10.50 * 1990 *Z=Space between the bar clamp contact surfaces Bar Clamp Assembly Components † Copper Bus Bar Width (in) Silicon Bronze Clamping Hardware Bar Clamp Bolts Nuts Split Lock Washers Run-A Tap-AA Qty Cat. No. Qty Cat. No. Qty Cat. No. Qty Cat. No. 2 2 2 HFB22P1 4 38 X (*) HEB 4 38CHEN 4 38SW 3 3 2 HFB33P1 4 38 X (*) HEB 4 38CHEN 4 38SW 4 2 2 HFB42P1 4 38 X (*) HEB 4 38CHEN 4 38SW 4 4 2 HFB44P1 4 50 X (*) HEB 4 50CHEN 4 50SW 6 3 2 HFB63P1 4 50 X (*) HEB 4 50CHEN 4 50SW 6 6 2 HFB66P1 4 62 X (*) HEB 4 62CHEN 4 62SW 8 8 2 HFB88P1 4 75 X (*) HEB 4 75CHEN 4 75SW † Ordered separately from BURNDY®. * See table below when ordering assembly clamping bolts to specify correct bolt length in Cat. #. Bolt Length Clamp Number “J” Bolt Dia. When Z = 1.25 When Z = 1.50 When Z = 1.75 When Z = 2.00 When Z = 2.25 When Z = 2.50 When Z = 2.75 When Z = 3.00 HFB22P1 3/8 3.00 3.25 3.50 4.00 4.00 4.50 4.50 5.00 HFB33P1 3/8 3.00 3.25 3.50 4.00 4.00 4.50 4.50 5.00 HFB42P1 3/8 3.00 3.25 3.50 4.00 4.00 4.50 4.50 5.00 HFB44P1 1/2 3.25 3.50 3.75 4.00 4.50 4.50 5.00 5.00 HFB63P1 1/2 3.25 3.50 3.75 4.00 4.50 4.50 5.00 5.00 HFB66P1 5/8 3.50 4.00 4.00 4.50 4.50 5.00 5.00 5.50 HFB88P1 3/4 3.75 4.00 4.50 4.50 5.00 5.00 5.50 5.50 NOTE: When ordering assembly bolts specify correct bolt length in catalog number as indicated in table. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-22 BURNDY® TYPE HFB-N BAR CLAMP TAP PAD ADAPTER For Copper Bar High conductivity copper, tap pad adapter provides a NEMA drilled contact pad when assembled to the HFB-P1 clamps. Tap connections can be made from copper bus bar(s) without drilling, by bolting standard mechanical or compression terminal pads directly to the pre-drilled tap pad adapter. Catalog Number Fig. # A&C E&F L N Use with ‘H’ Clamp Catalog Number 1 HFB33-4N 1 3.00 1.75 7.00 0.62 HFB33P1 HFB44-4N 1 4.00 1.75 9.12 1.12 HFB44P1 HFB66-6N 2 6.00 1.75 11.31 1.12 HFB66P1 1 ‘H’ Clamp (two required per assembly) and hardware (as shown) not included with bar clamp tap pad, order separately. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPES KA-U, KKA-U A-23 UNIVERSAL TERMINAL For Aluminum and Copper Conductors Fig. 1 Fig. 2 Fig. 3 Fig. 4 These dual-rated one-conductor lugs are constructed from high strength aluminum alloy and electro tin-plated to provide low contact resistance. AL9CU Fig. 5 Catalog Number* Fig. No. Wire Range Aluminum or Copper Stud Hole Size D L N ** W E T ** H Recommended Tightening ▲ Torque (in-lb) KA6U 1 14 AWG-6 AWG 1/4 0.63 1.06 0.25 0.50 — 0.09 0.51 45 KA2U 1 14-2 1/4 0.63 1.16 0.31 0.50 — 0.10 0.56 50 KA25U 1 14 AWG-1/0 1/4 0.81 1.50 0.44 0.63 — 0.19 0.92 50 KA26U 2 6-2/0 1/4 0.81 1.47 0.45 0.63 — 0.19 0.80 120 KA29U 2 6-250 5/16 0.94 2.00 0.47 1.00 — 0.25 1.14 275 KA30U 2 6 AWG-300 kcmil 5/16 0.94 2.00 0.45 1.00 — 0.25 1.14 275 KA31U 2 6 AWG-350 kcmil 3/8 1.03 2.25 0.52 1.13 — 0.25 1.27 275 KA34U 2 4 AWG-500 kcmil 3/8 1.50 2.81 0.88 1.51 — 0.31 1.58 500 KA36U 2 2 AWG-600 kcmil 3/8 1.72 3.19 0.78 1.50 — 0.44 1.58 500 KA40U 2 300 kcmil-800 kcmil 1/2 1.85 3.50 0.81 1.75 — 0.50 1.95 550 KA44U 2 500 kcmil-1000 kcmil 1/2 1.69 3.50 0.88 1.75 — 0.50 1.95 550 KKA31U-2N 3 6 AWG-350 kcmil 1/2 3.16 5.50 0.63 1.25 1.75 0.38 1.52 275 KA36U-2N 4 2 AWG-600 kcmil 1/2 3.22 4.69 0.63 1.50 1.75 0.44 1.57 500 KA40U-2N 4 300 kcmil-800 kcmil 1/2 3.03 4.75 0.63 1.75 1.75 0.50 1.95 500 KA44U-2N 4 500 kcmil-1000 kcmil 1/2 3.03 4.75 0.63 1.75 1.75 0.50 1.95 550 KA30226U 5 2 Str. - 300 kcmil or (2) 4 Str. - 2/0 Str. 5/16 1.31 2.31 2.00 0.86 – 0.25 1.50 275 KA36229U 5 4 Str. - 600 kcmil or (2) 250 kcmil - 1/0 Str. 5/8 1.50 2.81 1.00 1.38 – 0.31 1.81 375 KA39229U 5 1/0 Str. - 750 kcmil or (2) 1/0 Str. - 250 kcmil 1/2 1.50 2.81 1.00 1.38 – 0.31 1.81 375 * “N” indicates NEMA standard stud holes. ▲ Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. ** Maximum dimension. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-24 BURNDY® TYPES KA-UAR UNIVERSAL ANTI-ROTATE TERMINALS (One Conductor) For Aluminum and Copper Conductors These dual-rated one-conductor lugs are constructed from high strength aluminum alloy and electro tin-plated to provide low contact resistance. These lugs also contain a bottom anti-turn tab. AL9CU Wire Range Aluminum or Copper Stud Hole Size Depth Width Height Recommended Tightening ▲ Torque (in-lb) KA4UAR 14 - 4 1/4 1.16 0.50 0.55 45 KA25UAR 14 - 1/0 1/4 1.47 0.63 0.81 50 KA26UAR 14 - 2/0 1/4 1.47 0.63 0.81 120 KA30UAR 6 - 300 1/4 1.56 0.94 1.13 275 KA31UAR 6 - 350 5/16 1.19 1.00 1.13 275 KA36UAR 4 - 600 3/8 2.75 1.38 1.57 375 Catalog Number Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE K2A-U A-25 UNIVERSAL TERMINAL (Two Conductor) For Aluminum and Copper Conductors Fig. 1 Fig. 2 These dual-rated two-conductor lugs are constructed from high strength aluminum alloy and electro tin-plated to provide low contact resistance. AL9CU Fig. 3 Catalog Number* Fig. No. TWO: Wire Range (Aluminum or Copper) Stud Hole Size D L N ** W E T ** H Recommended Tightening ▲ Torque (in-lb) K2A25U 1 14 AWG-1/0 1/4 0.81 1.47 0.44 1.13 — 0.19 0.79 50 K2A26U 2 14 AWG-2/0 AWG 1/4 0.81 1.47 0.44 1.25 — 0.19 0.80 120 K2A29U 2 6 AWG-250 kcmil 3/8 1.50 2.56 0.50 1.66 — 0.25 1.20 275 K2A31U 2 6 AWG-350 kcmil 1/2 1.69 2.88 0.88 1.94 — 0.25 1.26 275 K2A36U 2 2 AWG-600 kcmil 1/2 1.75 3.20 0.63 2.41 — 0.44 1.58 375 K2A40U 2 300 kcmil-800 kcmil 5/8 1.66 3.38 0.88 3.19 — 0.50 1.95 500 K2A44U 2 500 kcmil-1000 kcmil 5/8 1.66 3.50 0.88 3.52 — 0.50 1.95 500 K2A31U-2N 3 6 AWG-350 kcmil 1/2 3.00 4.50 0.63 2.31 1.75 0.31 1.39 275 K2A36U-2N 3 2 AWG-600 kcmil 1/2 3.22 4.69 0.63 2.41 1.75 0.44 1.39 375 K2A40U-2N 3 300 kcmil-800 kcmil 1/2 3.03 4.75 0.63 3.19 1.75 0.50 1.95 375 K2A44U-2N 3 500 kcmil-1000 kcmil 1/2 3.03 4.75 0.63 3.19 1.75 0.50 1.95 375 * “N” indicates NEMA standard stud holes. ▲ Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. ** Maximum dimension. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-26 BURNDY® TYPES K3A-U, KK3A-U UNIVERSAL TERMINAL (Three Conductor) For Aluminum and Copper Conductors Fig. 1 Fig. 2 Dual-rated three-conductor lugs are constructed from high strength aluminum alloy and electro tinplated to provide low contact resistance. Fig. 3 AL9CU Fig. 4 Fig. 5 Catalog Number** Fig. No. THREE: Wire Range (Aluminum or Copper) K K3A2U-2* K3A25U-2* K3A26U-2N K3A27U-2N K3A29U-2N K3A31U-2N K3A36U-2N KK3A36U-2N KK3A40U-2N KK3A44U-2N K3A2U-4* K3A25U-4* K3A27U-4N K3A29U-4N K3A31U-4N K3A36U-4N K3A40U-4N KK3A36U-4N KK3A40U-4N KK3A44U-4N 1 1 3 3 3 3 3 2 2 2 4 4 4 4 4 4 4 5 5 5 14 AWG-2 AWG 14 AWG-1/0 14 AWG-2/0 AWG 6 AWG-3/0 AWG 6 AWG-250 kcmil 6 AWG-350 kcmil 2 AWG-600 kcmil 2 AWG-600 kcmil 300 kcmil-800 kcmil 500 kcmil-1000 kcmil 14 AWG-2 AWG 14 AWG-1/0 6 AWG-3/0 AWG 6 AWG-250 kcmil 6 AWG-350 kcmil 2 AWG-600 kcmil 300 kcmil-800 kcmil 2 AWG-600 kcmil 300 kcmil-800 kcmil 500 kcmil-1000 kcmil 11/32 7/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 11/32 7/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 * Slotted screw. ** ‘‘N” indicates NEMA standard stud holes. Stud Hole Size 5/16 3/8 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 5/16 3/8 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 Dimensions D L N W E T H 1.63 2.09 3.06 3.00 3.16 3.16 3.22 3.00 3.34 3.34 1.63 2.09 3.00 3.00 3.00 3.22 3.03 3.00 3.34 3.34 2.19 2.91 3.75 3.88 4.00 4.31 4.69 5.50 6.19 6.19 2.19 2.91 3.88 4.00 4.31 4.69 4.75 5.50 6.19 6.19 0.34 0.34 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.34 0.34 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 1.59 1.94 1.95 2.81 2.81 3.52 3.63 4.22 4.81 4.75 1.59 1.94 2.81 2.81 3.00 3.63 4.81 4.22 5.34 4.75 0.88 1.00 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 0.88 1.00 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 0.19 0.25 0.19 0.31 0.31 0.31 0.44 0.38 0.56 0.56 0.19 0.25 0.31 0.31 0.31 0.44 0.50 0.38 0.56 0.56 0.62 0.88 1.79 1.12 1.19 1.38 1.56 1.52 1.89 1.90 0.62 0.88 1.12 1.19 1.38 1.56 1.94 1.52 1.89 1.90 Rec. Tightening ▲ Torque (in-lb) 50 50 50 275 275 275 375 375 375 500 50 50 275 275 275 375 375 375 500 500 ▲ Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. All 4N items see note LIGHTNING PROTECTION INFO. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPES K4A-U, KK4A-U A-27 UNIVERSAL TERMINAL (Four Conductor) For Aluminum and Copper Conductors Fig. 1 Fig. 2 These dual-rated four conductor lugs are constructed from high strength aluminum alloy and electro tin-plated to provide low contact resistance. AL9CU Catalog Number* Fig. No. FOUR: Wire Range (Aluminum or Copper) Stud Hole Size Dimensions D L N W E T H Recommended Tightening Torque (in-lb) K4A29U-4N 1 6 AWG-250 kcmil 1/2 3.16 4.25 0.63 3.69 1.75 0.31 1.19 275 K4A31U-4N 1 6 AWG-350 kcmil 1/2 3.00 4.50 0.63 5.04 1.75 0.31 1.38 275 KK4A36U-4N 2 2 AWG-600 kcmil 1/2 3.34 5.63 0.63 5.00 1.75 0.44 1.51 375 KK4A40U-4N 2 300 kcmil-800 kcmil 1/2 3.41 6.19 0.63 6.00 1.75 0.56 1.88 375 * ‘‘N” indicates NEMA standard stud holes. All 4N items see note LIGHTNING PROTECTION INFO. TYPES K11A-U, K21A-U, K22A-U Fig. 2 Fig. 3 Fig. 1 UNIVERSAL TERMINAL For Aluminum and Copper Conductors Dual-rated panelboard lugs are constructed from high strength extruded aluminum alloy and electro tin-plated to provide low contact resistance. Fig. 5 Fig. 4 AL9CU Wire Range (Aluminum or Copper) Stud Hole Size D L 2 6 AWG-300 kcmil 5/16 0.94 2 4/0 AWG-500 kcmil 1/4 2.31 3 2 2 AWG-600 kcmil 3/8 K21A36U-2 4 3 2 AWG-600 kcmil K22A36U-2 5 4 2 AWG-600 kcmil K11A39U-2 3 2 K22A39U-2 5 4 Catalog Number Fig. No. # of Conductors K11A30U 1 K11A34U-2 2 K11A36U-2 H Recommended Tightening ▲ Torque (in-lb) 0.50 2.03 275 0.63 2.40 375 1.38 0.75 3.02 375 2.50 1.38 0.75 3.03 375 2.50 1.38 0.75 3.03 375 0.38 1.69 1.38 0.75 3.02 375 0.38 3.06 1.38 0.75 3.02 375 N W E T 3.00 0.47 2.91 0.25 1.00 — 1.44 0.69 2.31 4.91 0.38 1.50 3/8 2.31 3/8 2.31 4.91 0.38 4.91 0.38 1/0 -750 kcmil 3/8 1/0 -750 kcmil 3/8 2.31 4.91 2.31 4.91 ▲ Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-28 BURNDY® TYPES K6A-U, K8A-U, KK6A-U, KK8A-U UNIVERSAL TERMINALS (Six and Eight Conductor) For Aluminum and Copper Conductors Fig. 1 These dual-rated six and eight conductor lugs are constructed from high strength aluminum alloy and electro tin-plated to provide low contact resistance. Fig. 2 Catalog Number Fig. No. No. of Conductors No. of Mtg Holes Wire Range Aluminum or Copper Stud Hole Size Depth Width Height Rec. Tightening Torque in-lb ♦ K6A34U-8 1 6 8 2 AWG - 500 kcmil 9/16 4.63 6.75 1.56 375 K8A34U-10 1 8 10 2 AWG - 500 kcmil 9/16 4.63 8.75 1.56 375 KK6A31U-8 2 6 8 6 AWG - 350 kcmil 9/16 5.31 6.38 1.50 275 KK8A31U-10 2 8 10 6 AWG - 350 kcmil 9/16 5.31 8.13 1.50 275 KK6A34U-8 2 6 8 2 AWG - 500 kcmil 9/16 5.50 6.75 1.50 375 KK8A34U-10 2 8 10 2 AWG - 500 kcmil 9/16 5.50 8.75 1.50 375 KK8A39U-10 2 6 10 2 AWG - 750 kcmil 9/16 6.19 8.25 1.88 550 KK8A39U-12 2 8 12 2 AWG - 750 kcmil 9/16 6.19 10.25 1.88 550 KK6A44U-12 2 6 12 350 kcmil - 1000 kcmil 9/16 6.19 10.00 1.88 550 KK8A44U-14 2 8 14 350 kcmil - 1000 kcmil 9/16 6.19 12.12 1.88 550 ♦ Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, & 7-6 for smaller conductor sizes Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE KAU-KIT A-29 TRANSFORMER LUG KIT These dual-rated lugs are constructed from high strength aluminum alloy and electro tinplated to provide low contact resistance. Lugs and mounting hardware packaged together in these kits. Features & Benefits • Hardware packed in plastic bag ◊ No lost hardware prior to installation. • Larger 800 kcmil lugs in KIT3 and KIT4 ◊ Accommodates common 750 kcmil tap conductors in larger transformers. • UL Listed AL9CU dual rated set screw terminals and CSA Certified ◊ Ensure the transformer feeders and taps are terminated properly. • Plated steel cap screws and hex nuts with captive conical washers or individual Belleville washers ◊ Terminal to bus connections are made using proper hardware resulting in true torque to pressure performance compensates for dissimilar metal expansion and contraction. Terminals Catalog Number Transformer KVA Rating Qty Catalog Number Wire Range Aluminum or Copper KAU-KIT1 15 - 37.5 1Ø 15 - 45 3Ø 8 4 KA2U KA29U KAU-KIT2 50 - 75 1Ø 75 - 112.5 3Ø 12 KAU-KIT3 100 - 167 1Ø 150 - 300 3Ø KAU-KIT4 400 - 500 3Ø Hardware Qty Bolt Size Qty Nut Qty Washer 14 AWG-250 kcmil 8 1/4-20 X 3/4 HH 8 1/4 X 20 HN - Captive to Nut KA29U 6 AWG-250 kcmil 8 8 1/4-20 X 3/4 HH 1/4-20 X 2 HH 16 1/4 X 20 HN - Captive to Nut 6 7 K2A31U K2A40U 6 AWG-800 kcmil 5 6 1/2-13 X 3 HH 1/2-13 X 2-1/2 HH 11 1/2-13 HN 22 11 1/2 FW 1/2 Belleville 15 K2A40U 300 kcmil-800 kcmil 7 4 1/2-13 X 2 HH 1/2-13 X 2-1/2 HH 11 1/2-13 HN 22 11 1/2 FW 1/2 Belleville HH = Hex Head HN = Hex Nut FW = Flat Washer Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-30 BURNDY® TYPES K-AG1 ALUMINUM NEUTRAL BAR These aluminum neutral bars are dual rated for copper and aluminum conductors, and are manufactured from high strength 6061-T6 aluminum alloy and are electro tin plated to provide low contact resistance and protection against corrosion. Fig. 2 Fig. 1 AL9CU Fig. 3 Catalog Number Fig. Wire Range Aluminum or Copper Total Number of Holes Total Number of Circuits Mount Hole Locations Height Width Length K2P4CAG1 1 14 - 4 3 2 2 0.44 0.31 1.09 K3P4CAG1 1 14 - 4 5 3 1, 5 0.44 0.31 1.67 K9P4CAG1 1 14 - 4 11 9 4, 8 0.44 0.31 3.53 K13P4CAG1 1 14 - 4 15 13 6, 12 0.44 0.31 4.77 K15P4CAG1 1 14 - 4 17 15 6, 14 0.44 0.31 6.01 K5P6C2P1/0CAG1 2 14 - 1/0 14 - 6 7 (5) 14 - 6 (2) 14 - 1/0 – 0.62 0.38 2.26 K12P6C3P1/0CAG1 2 14 - 1/0 14 - 6 15 (12) 14 - 6 (3) 14 - 1/0 – 0.62 0.38 4.34 K14P6C5P1/0CAG1 2 14 - 1/0 14 - 6 19 (14) 14 - 6 (5) 14 - 1/0 – 0.62 0.38 5.77 K16P6C5P1/0CAG1 2 14 - 1/0 14 - 6 23 (16) 14 - 6 (5) 14 - 1/0 – 0.62 0.38 6.97 KAG1MTGBRKT ♦ 3 – – – – – – ♦ (2) KAG1MTGBRKT are necessary to mount neutral bars into enclosure Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPES K-G1 A-31 COPPER NEUTRAL BAR These copper neutral bars are manufactured from high strength pure electrolytic copper to insure maximum strength and conductivity. AL9CU Catalog Number Number of Outlets K6P4CG1 Conductor Range Mounting Holes Dimensions Width Length Line Circuit 6 14 - 4 6 - 14 0.20 0.23 0.34 3.56 K8P4CG1 8 14 - 4 6 - 14 0.20 0.47 0.34 4.37 K10P4CG1 10 14 - 4 6 - 14 0.20 0.75 0.34 5.15 K12P4CG1 12 14 - 4 6 - 14 0.20 0.75 0.34 5.94 K14P4CG1 14 14 - 4 6 - 14 0.20 0.75 0.34 6.75 K174P4CG1 174 14 - 4 6 - 14 none 0.47 0.34 69.00 Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-32 BURNDY® TYPE AMS DUAL RATED SPLICER/REDUCER For Copper and Aluminum Cable All splicer/reducers are dual rated for use with aluminum and copper conductors and are constructed from high strength, tin plated aluminum. PENETROX™ oxide inhibiting joint compounds are recommended for all aluminum applications. Features & Benefits • Large screw diameters ◊ Ensures greater surface contact with wires for maximum pullout force • Large cable ranges ◊ Each splice is also an effective reducing connector • All connectors are tin-plated ◊ Provide low contact resistance and prevents galvanic corrosion • Connectors feature rounded bottoms ◊ Facilitates taping • Solid center barrier ◊ Prevents contact of dissimilar metals Catalog Number Wire Range Aluminum & Copper L W H1 H2 Max Number of Screws Screw Diameter Hex Size AMS-2* 14 AWG-2 AWG 1-19/32 9/16 9/16 0.79 2 3/8 Slot AMS-0* 14 AWG-1/0 1-29/32 3/4 3/4 0.86 2 7/16 Slot AMS-4/0 6 AWG-4/0 AWG 2-5/16 1 1-3/32 1.28 2 9/16 5/16 AMS-250 6 AWG-250 kcmil 4-3/32 1 1-3/32 1.29 4 5/8 5/16 AMS-350 6 AWG-350 kcmil 4-11/32 1 1-3/32 1.3 4 11/16 5/16 AMS-500 3/0 AWG-500 kcmil 4-25/32 1-1/4 1-3/8 1.48 4 13/16 3/8 AMS-750 250 kcmil-750 kcmil 6-1/6 1-7/16 1-5/8 1.98 4 15/16 1/2 AMS-1000 500 kcmil-1000 kcmil 8-11/16 1-21/32 1-7/8 2.34 6 1-1/8 9/16 * Slotted Screws. H2 measured with maximum conductors, reference only. Complies with NFPA 78-86. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE AGSKIT A-33 ABOVE GRADE SPLICE KITS For all Aluminum or Copper/Aluminum Combinations Type AGS Above Grade Splice Kit consists of a standard AMS splice/reducer and a heavy wall heat-shrink sleeve. The AMS Splice is dual rated for use with aluminum and copper conductors and are constructed from high strength, tin plated aluminum that provides low contact resistance and reduces the effects of galvanic corrosion. Connector is installed with common installation tools. The heavy wall heat shrink sleeve is lined with adhesive material, providing a positive seal against moisture egress. Heat shrink sleeve is installed with standard propane torch, or electric heat gun. Fig. 2 Fig. 1 Catalog Number Figure Number Wire Range AGSKIT2 1 8 AWG-2 AWG AGSKIT250 2 1 AWG-250 kcmil TYPE UGSKIT WATERTIGHT/ UNDERGROUND SPLICE KITS For all Aluminum or Copper/Aluminum Combinations Type UGS Watertight Underground Splice Kit consists of a standard AMS splice/reducer and two heavy wall heat-shrink sleeves. The AMS Splice is dual rated for use with aluminum and copper conductors and are constructed from high strength, tin plated aluminum that provides low contact resistance and reduces the effects of galvanic corrosion. Connector installed with common installation tools. Both heavy wall heat shrink sleeves are lined with adhesive material, providing a watertight splice that can withstand abrasions that may occur during direct burial applications. Heat shrink sleeve installed with standard propane torch, or electric heat gun. Fig. 2 Fig. 1 Catalog Number Figure Number Wire Range UGSKIT2* 1 8 AWG-2 AWG UGSKIT250* 2 1 AWG-250 kcmil *UL486D Listed for Direct Burial Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-34 BURNDY® Direct Burial UNITAP™ Connectors UNITAP™ Dual Rated Multiple Tap Connector These rubber insulated, dual rated connectors are for use in networks up to 600V. Suitable in light fixture pole bases in commercial, industrial, or residential markets. Distribution within strip malls, for use in any multi-tenant facility. No taping or heat shrink required. Features & Benefits • Dual rated for aluminum or copper conductors Each unit is individually marked for ease of identification Supplied with aluminum set-screws Covering is the highest quality EPDM rubber Supplied with oxide inhibitor preinstalled • • • • • • • • • Suitable for direct burial Meets ANSI C119.1 and C119.4 requirements Rated 600V and 90° C; UL Listed and CSA Certified For use in wet or damp locations Silicone provided for conductor insertion L W H Wire Strip Length (in) 12 AWG-350 kcmil 2.61 4.06 2.46 1.125 12 AWG-350 kcmil 3.82 4.06 2.46 1.125 Catalog Number # of Ports Wire Range (AWG/kcmil) BIBS3502DB 2 BIBS3503DB 3 BIBS3504DB 4 12 AWG-350 kcmil 5.03 4.06 2.46 1.125 BIBS3505DB 5 12 AWG-350 kcmil 6.24 4.06 2.46 1.125 BIBS3506DB 6 12 AWG-350 kcmil 7.45 4.06 2.46 1.125 BIBS5003DB 3 10 AWG-500 kcmil 4.31 4.58 3.13 1.50 BIBS5004DB 4 10 AWG-500 kcmil 5.69 4.58 3.13 1.50 BIBS5005DB 5 10 AWG-500 kcmil 7.06 4.58 3.13 1.50 BIBS5006DB 6 10 AWG-500 kcmil 8.44 4.58 3.13 1.50 Recommended Torque Values for Direct Burial UNITAP™ Recommended BURNDY® Torque Wrench Conductor Size Recommended Torque Range #12 - #6 AWG 125 - 150 in-lbs BTW30150 #4 - 3/0 AWG 180 - 240 in-lbs BTW150750 4/0 - 350 AWG 275 - 450 in-lbs BTW150750 400 - 1000 AWG 475 - 550 in-lbs BTW150750 Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE UGSKIT8 A-35 UF DIRECT BURIAL SPLICE KIT Type UGS UF Splice Kit consists of a UF splice connector and a heavy wall heat-shrink sleeve. The UF splice connector can accommodate up to four UF conductors and is installed with common installation tools. The heavy wall heat shrink sleeve is lined with an adhesive material, providing a water-tight splice that can withstand abrasions that may occur during direct burial applications. Heat shrink sleeve installed with standard propane torch, or electric heat gun. Catalog Number Wire Range UGSKIT8* 14 AWG-8 AWG Copper *UL486D Listed for Direct Burial TYPE UGS350ULDB IN-LINE SPLICE/REDUCER For Direct Burial Features & Benefits • EPDM rubber covered 6061-T6 aluminum connector • Dual rated AL9CU for copper or aluminum conductor • UL Listed and CSA Certified for Direct Burial • Broad range taking capability • Low installation cost Catalog Number Wire Range Length Height Hex Size Torque (In. Lbs.) UGS350ULDB 12 AWG-350 kcmil 8.50 2.81 5/16 350 Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-36 BURNDY® BURNDY UNITAP™ THE MOLE™ For Direct Burial 600V, 90° C Designed specifically for direct burial applications, the MOLE™ in-line splice/reducer is made with a specialized plastisol material that forms a rugged weathertight connection. Features & Benefits • UL486D Listed for direct burial. • AL9CU Dual-rated for copper and aluminum applications. 600V 90°C. • Plastisol covered AL6061-T6 aluminum body saves time by eliminating the need for heat shrink. • Oxide inhibitor pre-installed preventing moisture and contaminants from entering contact area. • Range-taking capability reduces the number of connectors carried in inventory. Catalog Number Number of Ports Wire Range (AWG/ kcmil) L W H Hex Key Torque (In.-lbs.) Wire Strip Length BISR4-DB 2 #6 AWG-#4 AWG 4.30 0.68 1.39 1/8 50 7/8" BISR1-DB 2 #2 AWG-#1 AWG 6.30 0.88 1.75 5/32 130 1-3/32" BISR3/0-DB 2 1/0 -3/0 AWG 6.25 0.99 1.96 3/16 220 1-3/32" BISR250-DB 2 4/0 AWG-250 kcmil 6.70 1.18 2.17 5/16 360 1-5/16" BISR-DB = BURNDY Inline Splice/Reducer Direct Burial. UNITAP™ rated for code conductor only. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® QGFL A-37 BARTAP™ For Copper Cable to Flat Bar or Pad High copper alloy BARTAP™ for joining a range of cable to bar or pad. One-wrench installation. DURIUM™ nut and lockwasher. Catalog Number QGFL1CB1 QGFL1CB1T6 QGFL26B1 QGFL26B1T6 QGFL26B2* QGFL26B2T6* QGFL29B1* QGFL29B1T6* QGFL31B1* QGFL31B1T6* QGFL34B1 QGFL34B1T6 QGFL39B1 QGFL39B1T6 QGFL44B1 QGFL44B1T6 QGFL46B1 QGFL46B1T6 QGFL48B1 Copper Conductor #10 Sol-#1 Str #10 Sol-#1 Str #8 Sol-#2/0 Str #8 Sol-#2/0 Str #8 Sol-#2/0 Str #8 Sol-#2/0 Str #6 Str-250 kcmil #6 Str-250 kcmil 2 AWG-350 kcmil 2 AWG-350 kcmil 1/0 -500 kcmil 1/0 -500 kcmil 350 kcmil-750 kcmil 350 kcmil-750 kcmil 750 kcmil-1000 kcmil 750 kcmil-1000 kcmil 1000 kcmil-1500 kcmil 1000 kcmil-1500 kcmil 1500 kcmil-2000 kcmil B H J 1-1/8 1-1/8 1-1/4 1-1/4 1-1/4 1-1/2 1-2/5 1-5/8 1-3/4 1-3/4 2 2 2-1/4 2-1/4 2-1/4 2-1/4 2-1/4 2-1/4 2-1/4 1-7/8 2-3/8 2-1/8 2-5/8 2-8/25 2-40/50 2-5/8 3-1/8 2-7/8 3-1/4 3-1/8 3-5/8 3-1/4 3-5/8 3-3/8 4-1/8 4 4-1/2 4-3/4 3/8 3/8 3/8 3/8 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 T (Max) 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 W 1 1 1-1/8 1-1/8 1-1/8 1-1/8 1-3/8 1-3/8 1-5/8 1-5/8 1-3/4 1-3/4 1-3/4 1-3/4 2-1/8 2-1/8 2-1/2 2-1/2 3 * Can be installed side by side or in-line on NEMA drilled bar. FCB TRANSFORMER TAP ADAPTER Copper and Aluminum Cast in one piece from copper alloy. Transformer tap adapter designed to accommodate from 1 to 6 NEMA drilled copper or aluminum terminal taps from a single secondary transformer outlet. Tin-plated. Order mounting hardware and tap terminals separately. Catalog Number FCB63-4N FCB63-6N FCB64-4N FCB64-6N FCB65-4N FCB63-2NP300 FCB64-44NP50 Fig. No. 1 2 1 2 1 Not Shown Not Shown A Diameter 0.50 0.50 0.75 0.75 1.00 0.50 0.75 Fig. 1 H Ref. 5.25 5.25 5.75 5.75 7.00 5.00 9.00 L 3.75 5.50 4.00 5.75 4.25 3.50 5.00 P 2.25 2.25 2.75 2.75 4.00 3.00 5.00 Fig. 2 NOTE: All pads are NEMA drilled. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-38 BURNDY® TYPE KPU-AC POLYTAP™ Insulated Gutter Tap for All Copper and Aluminum Combinations Wide range-taking tin-plated aluminum parallel clamp and insulating cover assembly for industrial and multiple story structure applications. Only six connectors cover the entire 14 Sol.-750 kcmil range. Covers having flexible fingers that conform to conductor, fully insulating the connection. UL486B Listed for 600 volts maximum 90° C service. Cover and connector are packaged together. No taping required. 600 Volt Max. 90° C Conductor Copper or Aluminum Catalog Number W H L Rec. Tightening ▲ Torque in-lb Run Tap KPU29A26AC 1/0 -250 kcmil 14 AWG-2/0 AWG 3-1/8 3-3/8 4.24 375 KPU29A29AC 1/0 -250 kcmil 6 AWG-250 kcmil 3-1/8 3-3/8 4.24 375 KPU34A26AC 4/0 AWG-500 kcmil 14 AWG-2/0 AWG 3-1/2 3-1/2 4.58 450 KPU34A34AC 4/0 AWG-500 kcmil 6 AWG-500 kcmil 3-1/2 3-1/2 4.58 450 KPU39A26AC 500 kcmil-750 kcmil 14 AWG-2/0 AWG 3-1/2 3-83/100 5.06 600 KPU39A39AC 500 kcmil-750 kcmil 1/0 -750 kcmil 3-1/2 3-83/100 5.06 600 ▲ Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller combinations. See note LIGHTNING PROTECTION INFO. TYPE UCU-AC RISER TAP 600 VOLT MAX. 90° C MAX. Parallel-groove riser tap and insulation cover for copper and aluminum. Wide range-taking assembly for apartment house and light industrial applications. Cover and connector are packaged together. Covers having insulating fingers that conform to conductors, fully insulating the connection. UL486B Listed for 600 volts max. 90° C service. Catalog Number UCU28AC Conductor Copper or Aluminum Run Tap #2 Str.- 4/0 Str. #10 Sol. - #2 Str. W H L Recommended Tightening ▲ Torque in-lb 2-1/4 1-13/16 2-5/8 120 ▲ Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller combinations. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE BIPC A-39 UL Listed 90° C, *600 Volt The Type BIPC, BURNDY® Insulation Piercing Connector is ideally suited for splicing and tapping aluminum and copper conductor wire sizes: #10 AWG to 500 kcmil. Features & Benefits • Insulation piercing capability ◊ Eliminates the need for conductor insulation stripping. • UL486B Listed, AL9CU rated ◊ For copper and aluminum conductor combinations up to 90° *600 Volt applications. • Insulation piercing design ◊ For use on hot-line applications eliminates the need for taping. • Easy snap-out tabs ◊ Eases installation, protects connection from dirt and debris. • Simple bolt-on connection ◊ Eases installation. Fig. 2 Fig. 1 Bolt Size Socket Size H L W Recommended Tightening Torque Max. Voltage Rating 2 - 8 AWG 5/16 1/2 2.00 1.53 1.53 180 600 V 4/0 - 1/0 AWG 1/0 - 6 AWG 5/16 1/2 2.50 2.12 2.00 250 300 V BIPC4/0-1/0 4/0 - 1/0 AWG 4/0 - 1/0 AWG 5/16 1/2 2.50 2.12 2.06 250 300 V BIPC350-4/0 350 - 4/0 AWG 4/0 - 10 AWG 3/8 9/16 3.00 1.59 2.50 375 300 V BIPC350-350 350 - 4/0 AWG 350 - 4/0 AWG 3/8 9/16 3.00 2.62 2.75 300 300 V BIPC500-4/0* 500 - 350 kcmil 4/0 - 4 AWG 3/8 9/16 3.25 1.80 2.62 400 600 V Conductor Range Catalog Number Run Tap BIPC1/0-2* 1/0 - 8 AWG BIPC4/0-6 * 600 Volt Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-40 BURNDY® MISCELLANEOUS ACCESSORIES TERMINAL BLOCKS Molded General Purpose Phenolic Base 30 amps, #10 studs, 1 piece per card, 300-volt rating Meets UL component requirements CLASS B: Commercial Equipment CLASS C: General Industrial 300 V RMS 300 V RMS Withstands volts, Vdc Steel nickel plated screws 10,500 Catalog Number Number of Circuits General Description Overall Length RK149-2 2 2-3/32" RK150-2 4 3-7/32" RK225-2 6 RK151-2 8 RK152-2 10 RK226-2 12 Molded General Purpose Phenolic Base 30 amps, #10 studs 1 piece, per card 300-volt rating 4-11/32" 5-15/32" 6-19/32" 7-23/32" RK153-2 14 8-27/32" RK227-2 16 9-31/32" For bulk pack contact factory. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® POWER DISTRIBUTION BLOCKS A-41 U-BLOK™ For Junction Box Applications FT4B500 The U-BLOK™ system is a modern, state-ofthe-art approach to multi-load power distribution applications. Among typical uses are multi-story or multi-unit buildings, HVAC, refrigeration, control panels, motor control, switch gear, elevator systems and materials handling equipment. U-BLOK™ is UL Listed for Copper or Aluminum conductors and rated for 600-volt applications. U-BLOK™ can be mounted on bases for use in troughs or bolted directly to junction boxes. AL9CU rated. FT3B4/0 3S Features & Benefits 3U raised platforms ◊ Passage of cables under block means through-cables need not be terminated • Insulating covers and mounting blocks rated 94-VO ◊ Saves costly taping, time and material. Conforms to or exceeds building codes. • Connectors accommodate a wide range of wire sizes ◊ Reduces parts inventory requirements. • Feeder conductors can be cut or fed through on a continuous run ◊ Ease of installation. • Connector top slides OFF/ON for quick cable lay-in ◊ Labor savings. Easy access for installation, modifications or retrofit. • Electro-tin plated connectors in each pole ◊ Durability. High-conductivity and resistance to corrosion. • Compact size ◊ Requires less space than traditional connection methods. • Trough installations can be mounted on 3 WIRE POWER DISTRIBUTION BLOCKS Catalog Number Max. Number of Wires per Phase FT3B4/0 FT3B500 3S 2 2 2 3U 1 Run / 8 Tap Conductor Copper or Aluminum* Run Tap 3/0 - 4/0 6 - 4/0 400 - 500 6 - 500 250 - 350 6 - 350 3/0 - 500 6 - 1/0 W L H Weight Each 3-7/8 3-7/8 3-5/8 5-7/8 5-7/8 9-3/4 4-1/8 4-1/8 4-7/8 1-1/4 2-1/8 3 Allen Wrench Size 1/4 3/8 1/4 4-3/4 9-3/4 5-1/2 3 5/32 Recommended Tightening Strip Length Torque 200 1-1/2 375 2-5/16 200 1-3/4 2-5/16 (Run); 110 1-5/32 (Tap) 4 WIRE POWER DISTRIBUTION BLOCKS Catalog Number Max. Number of Wires per Phase FT4B4/0 FT4B500 4S 2 2 2 4U 1 Run / 8 Tap Conductor Copper or Aluminum* Run Tap 3/0 - 4/0 6 - 4/0 400 - 500 6 - 500 250 - 350 6 - 350 W L H Weight Each 3-7/8 3-7/8 3-5/8 7-7/8 7-7/8 11-3/4 4-1/8 4-1/8 4-7/8 3/0 - 500 4-3/4 11-3/4 5-1/2 6 - 1/0 PENETROX™ inhibitor is recommended for all aluminum wire connections. For two wire tap range is 8 through 1/0. 2 2-3/4 3-1/2 Allen Wrench Size 1/4 3/8 1/4 Recommended Tightening Torque 200 375 200 3-1/2 5/32 110 Strip Length 1-1/2 2-5/16 1-3/4 2-5/16 (Run); 1-5/32 (Tap) * Aluminum and copper conductors cannot be assembled under the same pressure plate or t-bar. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-42 BURNDY® U-BLOK™ MOUNTING PLATFORMS For Trough Applications Gutter Size Catalog Number W L TBPT6* 4-1/4 5-7/8 1-1/2 6' 3/4 TBPT8 4-1/4 7-7/8 3-1/2 8" 1-1/4 TBPT10 4-1/4 9-7/8 4 10" 1-1/2 TBPT12 4-1/4 11-7/8 4 12" 1-3/4 H Weight Each (lb) Hole pattern shown is for reference only. * Supercedes TBPT4/0-6 and TBPT350/500-6. FLEXI-TAP™ ALLOWABLE AMPACITIES OF INSULATED CONDUCTOR, 60° TO 90° C ** Copper Al or Copper Clad Al Size AWG kcmil 60 deg. C 75 deg. C 90 deg. C 60 deg. C 75 deg. C 90 deg. C 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750 25 30 40 55 70 85 95 110 125 145 165 195 215 240 260 280 320 355 385 400 25 35 50 65 85 100 115 130 150 175 200 230 255 285 310 335 380 420 460 475 30 40 55 75 95 110 130 150 170 195 225 260 290 320 350 380 430 475 520 535 20 25 30 40 55 65 75 85 100 115 130 150 170 190 210 225 260 285 310 320 20 30 40 50 65 75 90 100 120 135 155 180 205 230 250 270 310 340 375 385 25 35 45 60 75 85 100 115 135 150 175 205 230 255 280 305 350 385 420 435 ** NOTE: Values referenced from Article 310 of the National Electric Code, Table 310-16, 1996. The above chart is to be used for REFERENCE ONLY. Please consult Table 310-16 of the National Electric Code (latest revision) for information regarding insulation type, voltage range, and conductor housings/surroundings. U-TAP™, U-BLOK™, and SPEC-BLOK™ connectors are rated for 90 deg. C by Underwriters’ Laboratories. Use of 60 deg. C and 75 deg. C conductor(s) is valid, though only as determined by the National Electric Code. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® SPEC-BLOK™ POWER DISTRIBUTION CONNECTORS A-43 Unique, modular, made-to-order, power distribution assemblies accommodate any number of supply and load conductors in any number of poles. Capacity matches the conductors accommodated and SPEC-BLOK™ assures uniform loading. Adjacent poles are separated by easy-to handle, wrap-around insulating covers which eliminate taping and reduce heat build-up by allowing air to flow freely around connectors. SPEC-BLOK™ is UL Listed for copper or aluminum conductors for 600 volts. (AL9CU) Assemblies are mounted on platforms suitable for easy installation in wireway or junction box. Features & Benefits • Accommodate unlimited conductors ◊ Fits wide range of applications. Eliminates need for non-UL-Listed improvisation. • Connector elements tin-plated ◊ Provides high reliability, low-resistance connections. • User friendly, space-saving design ◊ Easy to install - saves labor. • 94-VO rated insulation folds into place insulating the components ◊ Saves time and material. Allows easy installation. • Connector caps removable for easy cable lay-in ◊ Saves labor. Makes installation easier - allows installation of straight-through conductors. Eases retrofit. • Belleville washers built-in on pressure screw assemblies, except in assemblies installed with a 5/32" Allen wrench ◊ Provides high-integrity connections. • Conductors can be cut or fed straight through ◊ Straight through installation ideal for riser applications. Contact BURNDY® or Technical Services: 1-800-451-4956, or BURNDY® Customer Service: 1-800-346-4175 Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-44 BURNDY® SPEC-BLOK™ Features & Benefits • 2 Wire (series), 4 (parallel), and Multi-Tap versions available ◊ Nearly any conductor combination can be terminated • Tin-plated Aluminum Alloy Construction ◊ High-strength, corrosion-resistant connector elements • All SPEC-BLOK™ connectors are custom made for nearly any Power Distribution system requirement ◊ Time savings — pre-assembled in our factory for immediate installation! • The SPEC-BLOK™ system includes 12 connector elements ◊ A wide variety of conductor sizes can be accommodated • Each element can be bolted together in parallel ◊ Provides an efficient flow of current from one element to another • AL9CU rated for Copper or Aluminum conductors ◊ Dual-rated system, with UL486B’s highest temperature rating A E W D S SPEC-BLOK™ CONNECTORS C B T Catalog Designation (Maximum Conductor) R Number of Conductors Accommodated Q (2/0) B R (250) C S (350) D 1 to 4 (0, 1 or 2 per cap) P Dimensions Length Without Insulator Second Conductor (if required) May Be Height On Max Conductors Width 4 Conductor 2 Conductor 1/0 - 2/0 #12 - 2/0 2-9/16" 1-1/2" 2-1/8" 7/8" 3/0 - 250 #6 - 250 3-1/8" 1-11/16" 4-1/4" 1-3/8" Allen Wrench Size 5/32" 1/4" 1 or 2 per cap T (500) E U AL or CU Wire Range Under Each Cap First 4 2 4 2 Conductors Conductor Conductor Conductor Conductor MUST Be A Q 250 - 350 #6 - 350 3-5/16" 1-13/16" 4-5/8" 1-1/2" 400 - 500 #6 - 500 4-1/16" 2" 5-5/8" 1-3/4" 3/8" W 600 - 750 (750) 3/0 - 750 4-7/8" 2-1/4" 7-1/4" Catalog Designation (Maximum Conductor) Number of Conductors Accommodated Large Groove Small Grooves** Height On Maximum Conductors Width P (1/0) 1 to 8 (0, 1 or 2 under each screw) __ 6 - 1/0 3-1/2" 2" U (1/0 & 500) 2 to 9 (0, 1 or 2 under each screw plus one large conductor) 3/0 - 500 6 - 1/0 4-1/8" 2" 2-5/8" Length Without Insulator Allen Wrench Size 1-3/4" 5/32" ** This range may be expanded to include #8 provided two conductors are being installed in that particular element. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® SPEC-BLOK™ A-45 MOUNTING PLATFORMS SPEC-BLOK™ Mounting Platforms are rigid steel construction with a black finish. They can be supplied for junction box mounting or wireway construction allowing trough conductors to pass underneath the assemblies. (CPB-) (CPT-) Catalog Number CPB6 CPB8 CPB10 CPB12 CPB14 CPB16-5/8 CPB21-1/4 L (Nominal) 6 8 10 12 14 16-5/8 21-1/4 Catalog Number CPT6 CPT8 CPT10 CPT12 CPT16 L (Nominal) 5-7/8 7-7/8 9-7/8 11-7/8 15-7/8 SPEC-BLOK™ catalog numbers describe exactly how the distribution block is assembled: L (Overall) 7-3/4 9-3/4 11-3/4 13-3/4 15-3/4 18-3/8 23 H 2-1/4 3 3-1/2 4 4 W (Overall) 2-1/2 2-1/2 2-1/2 3-1/2 3-1/2 3-1/2 3-1/2 W (Overall) 2-1/2 3-1/2 3-1/2 3-1/2 3-1/2 5DR-NDST-GQP-12 (assembly pictured) Total number of poles in the completed assembly 5 DR One ‘D’ unit and one ‘R’ unit, bolted in parallel, forming each phase pole (3 phase poles) N Denotes the beginning of the neutral pole (where required) DST One ‘D’ unit, one ‘S’ unit, and one ‘T’ unit, bolted in parallel, forming the neutral pole G Denotes the beginning of the ground pole description (where required) QP One ‘Q’ unit and one ‘P’ unit, bolted in parallel, forming the ground pole 12 Size (inches) of the wireway or trough that is needed to enclose the assembly. If a junction box enclosure is used, no number is used to denote the size of the enclosure SPEC-BLOK™ IS A SYSTEM THAT CAN SOLVE MOST POWER DISTRIBUTION APPLICATIONS! Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-46 BURNDY® Questionnaire For spec-blok™ Applications How many poles in the system? (3-wire, 4-wire, single phase, etc.)?___________ poles Are neutral conductors (when required) different sizes (AWG/kcmil) than the phase conductors? ___________ same size ___________ different size Is a ground connection required? □ Yes □ No What are the quantities, sizes (AWG/kcmil) and material (AI/Cu) of the incoming line conductors and outgoing load conductors? QUANTITY PER PHASE PER PHASE SIZE CONDUCTOR TYPE LINE LOAD LINE LOAD PER PHASE LINE LOAD Are any conductors continuous? □ Yes □ No If yes, which ones? ______________________________________________________________________________________ _______________________________________________________________________________________________________ What kind of enclosure is the connection assembly being mounted in and what are the inside space dimensions? Wireway/trough size _______________________________________________________________________________________ Box, panel, cabinet, other size _______________________________________________________________________________ When is a quotation required? Date ___________________ When is the material required? Date __________________ Name of requestor __________________________________ Job name/reference ________________________________ Is there a preference for a particular BURNDY distributor? □ Yes □ No If yes, please give the name, location and telephone number Name ________________________________________________________________ Phone______________________________ Address ________________________________________________________________________________________________ ________________________________________________________________________________________________ Questions?items Call BURNDY Technical at frequently 800-451-4956. Blue highlighted are industry standardServices and most ordered. ® US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® UL LISTED POWER DISTRIBUTION BLOCKS A-47 VERSIPOLE™ These Power Distribution Blocks are Listed to the Power Distribution Block Standard UL 1953. They contain the same features and characteristics as the non-Listed blocks however, these have spacings that are suitable for installations in most industrial control panel feeder and branch circuits, HVAC systems, and Wireways (with optional cover; sold separately). They are available in one, two, or three pole configurations. An “Adder” is also available with optional End Barrier (sold separately), to allow user customized configurations. Features & Benefits • • • • • • • • Single or dual run connections allow the user to minimize the number of connections required Suitable for use with aluminum or copper conductors providing maximum versatility Available in 3 sizes for optimization of space 600V, ALCU Rated; meets or exceeds industry standard requirements Range taking designs to accommodate wire sizes up to 600 kcmil High Short-Circuit Rating up to 100kA with proper fusing Meets spacing requirements of Industrial Control Panel Standard UL 508A (spacing of 1” through air and 2” over surface) • 1 Adders and End Barriers available separately for all 3 sizes providing capability to create as many poles as required Hinged Covers available separately to cover 3 sizes providing user protection and easy access to connector terminal block Short-Circuit Current Rating with proper fusing Small Series: Connector Run Tap Number of Run(s) Number of Tap(s) Wire Range AL9CU Wire Range AL9CU Width Height Depth Ampere Rating per Pole Number of Poles SCCR1 BDCSHC142/01 1 4 14-2/0 14-4 1.05 2.81 3.08 175 1 100kA BDASHC142/01 1 4 14-2/0 14-4 0.93 2.81 3.08 175 Adder 100kA BDCSHC112/01 1 1 14-2/0 14-2/0 1.05 2.81 3.08 175 1 100kA BDASHC112/01 1 1 14-2/0 14-2/0 0.93 2.81 3.08 175 Adder 100kA Catalog Number Small Series Hinged Cover and End Barrier: Catalog Number Description BDASHCEB End Barrier for Small Series Adder Distribution Blocks BDBSHCCOVER Hinged Cover for use with Small Series Distribution Blocks and Adders (use of End Barrier necessary with Adders to attach cover). Order 1 cover per pole Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-48 BURNDY® UL LISTED POWER DISTRIBUTION BLOCKS VERSIPOLE™ Medium Series: Catalog Number Connector Run Tap Number Number of Run(s) of Tap(s) Wire Range AL9CU Wire Range AL9CU Width Height Depth Ampere Rating per Pole Number of Poles SCCR1 BDBMHC162/01 1 6 14-2/0 14-2 1.85 3.25 5 175 1 100kA BDBMHC162/02 1 6 14-2/0 14-2 3.57 3.25 5 175 2 100kA BDBMHC162/03 1 6 14-2/0 14-2 5.28 3.25 5 175 3 100kA BDAMHC162/0 1 6 14-2/0 14-2 1.72 3.25 5 175 Adder 100kA BDBMHC112/01 1 1 14-2/0 14-2/0 1.85 3.25 5 175 1 100kA BDBMHC112/02 1 1 14-2/0 14-2/0 3.57 3.25 5 175 2 100kA BDBMHC112/03 1 1 14-2/0 14-2/0 5.28 3.25 5 175 3 100kA BDAMHC112/0 1 1 14-2/0 14-2/0 1.72 3.25 5 175 Adder 100kA BDBMHC113501 1 1 6-350 6-350 1.85 3.25 5 310 1 100kA BDBMHC113502 1 1 6-350 6-350 3.57 3.25 5 310 2 100kA BDBMHC113503 1 1 6-350 6-350 5.28 3.25 5 310 3 100kA BDAMHC11350 1 1 6-350 6-350 1.72 3.25 5 310 Adder 100kA BDBMHC262/01 2 6 14-2/0 14-2 1.85 3.25 5 350 1 100kA BDBMHC262/02 2 6 14-2/0 14-2 3.57 3.25 5 350 2 100kA BDBMHC262/03 2 6 14-2/0 14-2 5.28 3.25 5 350 3 100kA BDAMHC262/0 2 6 14-2/0 14-2 1.72 3.25 5 350 Adder 100kA BDBMHC222/01 2 2 14-2/0 14-2/0 1.85 3.25 5 350 1 100kA BDBMHC222/02 2 2 14-2/0 14-2/0 3.57 3.25 5 350 2 100kA BDBMHC222/03 2 2 14-2/0 14-2/0 5.28 3.25 5 350 3 100kA BDAMHC222/0 2 2 14-2/0 14-2/0 1.72 3.25 5 350 Adder 100kA BDBMHC145001 1 4 4-500 14-2/0 1.85 3.25 5 380 1 100kA BDBMHC145002 1 4 4-500 14-2/0 3.57 3.25 5 380 2 100kA BDBMHC145003 1 4 4-500 14-2/0 5.28 3.25 5 380 3 100kA BDAMHC14500 1 4 4-500 14-2/0 1.72 3.25 5 380 Adder 100kA BDBMHC1625001 1 6 4-500 14-2 1.85 3.25 5 380 1 100kA BDBMHC1625002 1 6 4-500 14-2 3.57 3.25 5 380 2 100kA BDBMHC1625003 1 6 4-500 14-2 5.28 3.25 5 380 3 100kA BDAMHC162500 1 6 4-500 14-2 1.72 3.25 5 380 Adder 100kA Medium Series Hinged Cover and End Barrier: Catalog Number Description BDAMHCEB End Barrier for Medium Series Adder Distribution Blocks BDBMHCCOVER Hinged Cover for use with Medium Series Distribution Blocks and Adders (use of End Barrier necessary with Adders to attach cover). Order 1 cover per pole Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® UL LISTED POWER DISTRIBUTION BLOCKS A-49 VERSIPOLE™ Large Series: Connector Run Tap Width Height Depth Ampere Rating per Pole Number of Poles SCCR1 14-4 2.73 3.55 5.7 310 1 100kA 14-4 5.31 3.55 5.7 310 2 100kA 14-4 7.89 3.55 5.7 310 3 100kA 6-350 14-4 2.58 3.55 5.7 310 Adder 100kA 6-350 4-2/0 2.73 3.55 5.7 310 1 100kA 6 6-350 4-2/0 5.31 3.55 5.7 310 2 100kA 1 6 6-350 4-2/0 7.89 3.55 5.7 310 3 100kA 1 6 6-350 4-2/0 2.58 3.55 5.7 310 Adder 100kA BDBLHC115001 1 1 4-500 4-500 2.73 3.55 5.7 380 1 100kA BDBLHC115002 1 1 4-500 4-500 5.31 3.55 5.7 380 2 100kA BDBLHC115003 1 1 4-500 4-500 7.89 3.55 5.7 380 3 100kA BDALHC11500 1 1 4-500 4-500 2.58 3.55 5.7 380 Adder 100kA BDBLHC165001 1 6 4-500 4-2/0 2.73 3.55 5.7 380 1 100kA BDBLHC165002 1 6 4-500 4-2/0 5.31 3.55 5.7 380 2 100kA BDBLHC165003 1 6 4-500 4-2/0 7.89 3.55 5.7 380 3 100kA BDALHC16500 1 6 4-500 4-2/0 2.58 3.55 5.7 380 Adder 100kA BDBLHC2125001 2 12 4-500 14-4 2.73 3.55 5.7 760 1 100kA Catalog Number Number of Run(s) Number of Tap(s) Wire Range AL9CU Wire Range AL9CU BDBLHC1123501 1 12 6-350 BDBLHC1123502 1 12 6-350 BDBLHC1123503 1 12 6-350 BDALHC112350 1 12 BDBLHC163501 1 6 BDBLHC163502 1 BDBLHC163503 BDALHC16350 BDBLHC2125002 2 12 4-500 14-4 5.31 3.55 5.7 760 2 100kA BDBLHC2125003 2 12 4-500 14-4 7.89 3.55 5.7 760 3 100kA BDALHC212500 2 12 4-500 14-4 2.58 3.55 5.7 760 Adder 100kA BDBLHC263501 2 6 6-350 14-2/0 2.73 3.55 5.7 620 1 100kA BDBLHC263502 2 6 6-350 14-2/0 5.31 3.55 5.7 620 2 100kA BDBLHC263503 2 6 6-350 14-2/0 7.89 3.55 5.7 620 3 100kA BDALHC26350 2 6 6-350 14-2/0 2.58 3.55 5.7 620 Adder 100kA BDBLHC223501 2 2 6-350 6-350 2.73 3.55 5.7 620 1 100kA BDBLHC223502 2 2 6-350 6-350 5.31 3.55 5.7 620 2 100kA BDBLHC223503 2 2 6-350 6-350 7.89 3.55 5.7 620 3 100kA BDALHC22350 2 2 6-350 6-350 2.58 3.55 5.7 620 Adder 100kA BDBLHC225001 2 2 4-500 4-500 2.73 3.55 5.7 760 1 100kA BDBLHC225002 2 2 4-500 4-500 5.31 3.55 5.7 760 2 100kA BDBLHC225003 2 2 4-500 4-500 7.89 3.55 5.7 760 3 100kA BDALHC22500 2 2 4-500 4-500 2.58 3.55 5.7 760 Adder 100kA Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-50 BURNDY® UL LISTED POWER DISTRIBUTION BLOCKS VERSIPOLE™ Large Series (continued): Connector Run Tap Catalog Number Number of Run(s) Number of Tap(s) Wire Range AL9CU Wire Range AL9CU Width Height Depth Ampere Rating per Pole Number of Poles SCCR1 BDBLHC265001 2 6 4-500 14-2/0 2.73 3.55 5.7 760 1 100kA BDBLHC265002 2 6 4-500 14-2/0 5.31 3.55 5.7 760 2 100kA BDBLHC265003 2 6 4-500 14-2/0 7.89 3.55 5.7 760 3 100kA BDALHC26500 2 6 4-500 14-2/0 2.58 3.55 5.7 760 Adder 100kA BDBLHC245001 2 4 4-500 6-4/0 2.73 3.55 5.7 760 1 100kA BDBLHC245002 2 4 4-500 6-4/0 5.31 3.55 5.7 760 2 100kA BDBLHC245003 2 4 4-500 6-4/0 7.89 3.55 5.7 760 3 100kA BDALHC24500 2 4 4-500 6-4/0 2.58 3.55 5.7 760 Adder 100kA BDBLHC226001 2 2 2-600 2-600 2.73 3.55 5.7 840 1 100kA BDBLHC226002 2 2 2-600 2-600 5.31 3.55 5.7 840 2 100kA BDBLHC226003 2 2 2-600 2-600 2.73 3.55 5.7 840 3 100kA BDALHC22600 2 2 2-600 2-600 2.58 3.55 5.7 840 Adder 100kA Large Series Hinged Cover and End Barrier: Catalog Number Description BDALHCEB End Barrier for Large Series Adder Distribution Blocks BDBLHCCOVER Hinged Cover for use with Large Series Distribution Blocks and Adders (use of End Barrier necessary with Adders to attach cover). Order 1 cover per pole Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® VERSIPOLE™ A-51 POWER DISTRIBUTION BLOCKS VERSIPOLE™ Power Distribution Blocks are designed to provide modular solutions to power distribution applications. Each connector element is made from a high conductivity aluminum alloy which is insulated with a high strength polymer housing. One, two, and three pole versions available. “Add” a pole (snap-together) blocks are also available for wire sizes up to 500 kcmil. For use with Cu or Al. 600 V, AL9CU rated. VERSIPOLE™ Snap-Together Blocks Features and Benefits • “Add” a pole feature available ◊ Provides capability to create as many poles as required • Up to 30 tap conductors accommodated ◊ Ideal for current distribution to multiple locations • Single or dual run connections ◊ Allows user to minimize the number of connectors needed to do the job • Suitable for use with aluminum or copper conductors ◊ Provides maximum versatility • 600 V, AL9CU rated* ◊ Meets or exceeds industry standard requirements • Dead-front covers available ◊ Provides user protection – one cover per pole * BDB-430-500-1 not CSA certified Run Tap Wire Range AL9CU Wire Range AL9CU Ampere Rating per Pole Number of Poles BDA-112-350 AWG 6 - 350 kcmil AWG 14 - 4 310 ADDER BDA-16-350 AWG 6 - 350 kcmil AWG 14 - 2/0 310 ADDER BDA-16-500 AWG 4 - 500 kcmil AWG 4 - 2/0 380 ADDER BDA-26-350 AWG 6 - 350 kcmil AWG 14 - 2/0 620 ADDER BDA-212-500 AWG 4 - 500 kcmil AWG 14 - 4 760 ADDER BDA-26-500 AWG 4 - 500 kcmil AWG 14 - 2/0 760 ADDER BDA-24-500 AWG 4 - 500 kcmil AWG 6 - 4/0 760 ADDER BDA-11-500 AWG 4 - 500 kcmil AWG 4 - 500 kcmil 380 ADDER BDA-22-350 AWG 6 - 350 kcmil AWG 6 - 350 kcmil 620 ADDER BDA-22-500 AWG 4 - 500 kcmil AWG 4 - 500 kcmil 760 ADDER Catalog Number Connector Run Tap NOTES: 1. Order Optional BDB COVER1 per pole if desired. 2. Snap-together blocks can also be assembled to 1, 2, 3 pole blocks to create multi-pole distribution blocks. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-52 BURNDY® VERSIPOLE™ VERSIPOLE™ 1, 2, 3 Pole Distribution Blocks Run Tap Wire Range AL9CU Wire Range AL9CU Ampere Rating per Pole Number of Poles Optional Cover Order 1 per Pole BDB-16-2/0-1 BDB-16-2/0-2 BDB-16-2/0-3 AWG 12 - 2/0 AWG 14 - 4 175 1 2 3 BDBCOVER2 BDB-26-2/0-1 BDB-26-2/0-2 BDB-26-2/0-3 AWG 14 - 2/0 AWG 14 - 2 350 1 2 3 BDBCOVER2 BDB-112-350-1 BDB-112-350-2 BDB-112-350-3 AWG 6 - 350 kcmil AWG 14 - 4 310 1 2 3 BDBCOVER1 BDB-16-350-1 BDB-16-350-2 BDB-16-350-3 AWG 6 - 350 kcmil AWG 14 - 2/0 310 1 2 3 BDBCOVER1 BDB-14-500-1 BDB-14-500-2 BDB-14-500-3 AWG 4 - 500 kcmil AWG 14 - 2/0 380 1 2 3 BDBCOVER2 BDB-16-500-1 BDB-16-500-2 BDB-16-500-3 AWG 4 - 500 kcmil AWG 14 - 2/0 380 1 2 3 BDBCOVER1 BDB-162-500-1 BDB-162-500-2 BDB-162-500-3 AWG 4 - 500 kcmil AWG 14 - 2 380 1 2 3 BDBCOVER2 BDB-26-350-1 BDB-26-350-2 BDB-26-350-3 AWG 6 - 350 kcmil AWG 14 - 2/0 620 1 2 3 BDBCOVER1 BDB-212-500-1 BDB-212-500-2 BDB-212-500-3 AWG 4 - 500 kcmil AWG 14 - 4 760 1 2 3 BDBCOVER1 BDB-26-500-1 BDB-26-500-2 BDB-26-500-3 AWG 4 - 500 kcmil AWG 14 - 2/0 760 1 2 3 BDBCOVER1 BDB-24-500-1 BDB-24-500-2 BDB-24-500-3 AWG 4 - 500 kcmil AWG 6 - 4/0 760 1 2 3 BDBCOVER1 Connector Catalog Number Run Tap Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® VERSIPOLE™ A-53 VERSIPOLE™ 1, 2, 3 Splice/Reducer Blocks Run Tap Wire Range AL9CU Wire Range AL9CU Ampere Rating per Pole BDB-11-2/0-1 BDB-11-2/0-2 BDB-11-2/0-3 AWG 14 - 2/0 AWG 14 - 2/0 175 1 2 3 BDBCOVER2 BDB-11-350-1 BDB-11-350-2 BDB-11-350-3 AWG 6 - 350 kcmil AWG 6 - 350 kcmil 310 1 2 3 BDBCOVER2 BDB-11-500-1 BDB-11-500-2 BDB-11-500-3 AWG 6 - 500 kcmil AWG 6 - 500 kcmil 380 1 2 3 BDBCOVER1 BDB-22-2/0-1 BDB-22-2/0-2 BDB-22-2/0-3 AWG 14 - 2/0 AWG 14 - 2/0 350 1 2 3 BDBCOVER2 BDB-22-350-1 BDB-22-350-2 BDB-22-350-3 AWG 6 - 350 kcmil AWG 6 - 350 kcmil 620 1 2 3 BDBCOVER1 BDB-22-500-1 BDB-22-500-2 BDB-22-500-3 AWG 4 - 500 kcmil AWG 4 - 500 kcmil 760 1 2 3 BDBCOVER1 Run Tap Wire Range AL9CU Wire Range AL9CU Ampere Rating per Pole Number of Poles Optional Cover Order 1 per Pole BDC-14-2/0-1 AWG 14 - 2/0 AWG 14 - 4 175 1 BDBCOVER3 BDA-14-2/0-1 AWG 14 - 2/0 AWG 14 - 4 175 ADDER BDBCOVER3 BDC-11-2/0-1 AWG 14 - 2/0 AWG 14 - 2/0 175 1 BDBCOVER3 BDA-11-2/0-1 AWG 14 - 2/0 AWG 14 - 2/0 175 ADDER BDBCOVER3 Connector Catalog Number Run Tap Number of Poles Optional Cover Order 1 per Pole SNAP TOGETHER SPLICE/REDUCER BLOCKS Connector Catalog Number Run Tap Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-54 BURNDY® VERSIPOLE™ (Continued) These tables and illustrations refer to the specific VERSIPOLE™ Power Distribution Blocks listed. VERSIPOLE™ 1, 2, 3 Splice/Reducer Blocks The Figure to the Lower Right is Applicable to the Following: Number of Poles Catalog Number Number of Poles BDA-11-500 Catalog Number 1 (adder) BDB-16-500-3 3 BDA-112-350 1 (adder) BDB-212-500-1 1 BDA-16-350 1 (adder) BDB-212-500-2 2 BDA-16-500 1 (adder) BDB-212-500-3 3 BDA-212-500 1 (adder) BDB-22-350-1 1 BDA-22-350 1 (adder) BDB-22-350-2 2 BDA-22-500 1 (adder) BDB-22-350-3 3 BDA-24-500 1 (adder) BDB-22-500-1 1 BDA-26-350 1 (adder) BDB-22-500-2 2 BDA-26-500 1 (adder) BDB-22-500-3 3 BDB-11-500-1 1 BDB-24-500-1 1 BDB-11-500-2 2 BDB-24-500-2 2 BDB-11-500-3 3 BDB-24-500-3 3 BDB-112-350-1 1 BDB-26-350-1 1 BDB-112-350-2 2 BDB-26-350-2 2 BDB-112-350-3 3 BDB-26-350-3 3 BDB-16-350-1 1 BDB-26-500-1 1 BDB-16-350-2 2 BDB-26-500-2 2 BDB-16-350-3 3 BDB-26-500-3 3 BDB-16-500-1 1 BDB-430-500-1* 1 BDB-16-500-2 2 * BDB-430-500-1 not CSA certified No. of Poles Dimensions A Inches Adder 1 2 3 N 2.50 2.81 5.31 7.81 (2.50 X N) + 0.31 Example for 10 poles: A = (2.50 X 10) + 0.31 = 25 Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® VERSIPOLE™ A-55 (Continued) VERSIPOLE™ 1, 2, 3 Splice/Reducer Blocks These tables and illustrations refer to the specific VERSIPOLE™ Power Distribution Blocks listed. The Figure to the Lower Right is Applicable to the Following: Catalog Number Number of Poles BDB-11-2/0-1 BDB-11-2/0-2 BDB-11-2/0-3 BDB-11-350-1 BDB-11-350-2 BDB-11-350-3 BDB-14-500-1 BDB-14-500-2 BDB-14-500-3 BDB-16-2/0-1 BDB-16-2/0-2 BDB-16-2/0-3 BDB-162-500-1 BDB-162-500-2 BDB-162-500-3 BDB-22-2/0-1 BDB-22-2/0-2 BDB-22-2/0-3 BDB-26-2/0-1 BDB-26-2/0-2 BDB-26-2/0-3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 No. of Poles Dimensions A Inches Adder 1 2 3 N 1.64 1.94 3.57 5.20 (1.64 X N) + 0.30 Example for 10 poles: A = (1.64 X 10) + 0.30 = 16.20 Applicable VERSI-POLETM Items Catalog Number Number of Poles BDA-14-2/0-1 BDC-14-2/0-1 BDA-11-2/0-1 BDC-11-2/0-1 1 (adder) 1 1 (adder) 1 No. of Poles Dimensions A Inches Adder 1 2 3 N 0.81 1.08 1.89 2.70 (0.81 X N) + 0.27 Example for 10 poles: A = (.81 X 10) + 0.30 = 8.37 Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-56 BURNDY® TYPES BIT, BITO, BISR UNITAP™ Clear Insulated Multiple Tap Connectors Fig. 1 Tap connections and in-line splice/reductions are made quickly and easily with the UNITAP™ line of connectors. UL486B Listed. Dual-rated AL9CU for any stranded copper or stranded aluminum applications. 600 Volt, 90° C. 2 Port, 1 or 2 Sided Entry Catalog Number BIT4 BITO4 BIT2/0 BITO2/0 BIT250 BITO250 BIT350 BITO350 BIT600 BITO600 BIT750 * BITO750 * # of Ports 2 2 2 2 2 2 2 2 2 2 2 2 Fig. 2 Features & Benefits • Clear Plastisol covered AL6061-T6 aluminum body ◊ Saves time, lowers installation costs, eliminates taping. • Clear Plastisol ◊ Allows visual confirmation that conductor is properly inserted. • Oxide inhibitor pre-installed ◊ Inhibits moisture and contaminants from entering the contact area. • Range-taking ◊ Reduces number of connectors carried in inventory. Wire Range (AWG/kcmil) L 14 AWG-4 AWG 1.16 14 AWG-2/0 AWG 1.52 10 AWG-250 kcmil 2.03 10 AWG-350 kcmil 2.22 4 AWG-600 kcmil 2.72 2 AWG-750 kcmil 2.87 W 1.16 1.50 1.40 1.56 2.07 2.64 2.32 3.00 2.38 3.00 2.70 3.38 H Hex Key 1.25 1/8 1.38 3/16 2.13 5/16 3/16 5/16 3/16 3/8 3/16 3/8 2.50 2.75 3.00 Figure Number 1 2 1 2 1 2 1 2 1 2 1 2 * BIT750 and BITO750 are not UL Listed. UNITAP™ rated for code conductor only. In-Line Splicer/Reducer Catalog Number Wire Range (AWG/kcmil) L W H Hex Key BISR2 #14-2 2.38 0.75 1.22 5/32 BISR1/0 #14-1/0 2.91 0.91 1.38 3/16 BISR250 #10-250 4.01 1.19 2.10 5/16 BISR350 #10-350 4.63 1.34 2.35 5/16 BISR500 #6-500 5.00 1.62 2.62 3/8 Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE BIBS A-57 UNITAP™ Clear Insulated Multiple Tap Connectors Tap connections and in-line splice/reductions are made quickly and easily with the UNITAP™ line of connectors. UL486B Listed. Dual-rated AL9CU for any stranded copper or stranded aluminum applications. 600 Volt, 90° C. Features & Benefits • Clear Plastisol covered AL6061-T6 aluminum body ◊ Saves time, lowers installation costs, eliminates taping • Clear Plastisol ◊ Allows visual confirmation that conductor is properly inserted • Oxide inhibitor pre-installed ◊ Inhibits moisture and contaminants from entering the contact area • Range-taking ◊ Reduces number of connectors carried in inventory MULTI-PORT Single-Sided Entry Catalog Number BIBS4-3 BIBS4-4 BIBS4-5 BIBS4-6 BIBS4-8 BIBS2/0-3 BIBS2/0-4 BIBS2/0-5 BIBS2/0-6 BIBS2/0-8 BIBS2/0-10 BIBS2/0-12 BIBS2/0-14 BIBS250-3 BIBS250-4 BIBS250-5 BIBS250-6 BIBS250-8 BIBS250-10 BIBS250-12 BIBS250-14 BIBS350-3 BIBS350-4 BIBS350-5 BIBS350-6 BIBS350-8 BIBS350-10 # of Ports Wire Range (AWG/kcmil) L W H Hex Key 3 14 AWG-4 AWG 1.51 1.25 1.25 1/8 4 14 AWG-4 AWG 1.95 1.25 1.25 1/8 5 14 AWG-4 AWG 2.39 1.25 1.25 1/8 6 14 AWG-4 AWG 2.83 1.25 1.25 1/8 8 14 AWG-4 AWG 3.71 1.25 1.25 1/8 3 14 AWG-2/0 Str 2.19 1.31 1.38 3/16 4 14 AWG-2/0 Str 2.86 1.31 1.38 3/16 5 14 AWG-2/0 Str 3.53 1.31 1.38 3/16 6 14 AWG-2/0 Str 4.20 1.31 1.38 3/16 8 14 AWG-2/0 Str 5.55 1.31 1.38 3/16 10 14 AWG-2/0 Str 6.89 1.31 1.38 3/16 12 14 AWG-2/0 Str 8.24 1.31 1.38 3/16 14 14 AWG-2/0 Str 9.58 1.31 1.38 3/16 3 10 AWG-250 kcmil 2.97 2.07 2.13 5/16 4 10 AWG-250 kcmil 3.91 2.07 2.13 5/16 5 10 AWG-250 kcmil 4.84 2.07 2.13 5/16 6 10 AWG-250 kcmil 5.78 2.07 2.13 5/16 8 10 AWG-250 kcmil 7.66 2.07 2.13 5/16 10 10 AWG-250 kcmil 9.53 2.07 2.13 5/16 12 10 AWG-250 kcmil 11.41 2.07 2.13 5/16 14 10 AWG-250 kcmil 13.29 2.07 2.13 5/16 3 10 AWG-350 kcmil 3.13 2.32 2.50 5/16 4 10 AWG-350 kcmil 4.04 2.32 2.50 5/16 5 10 AWG-350 kcmil 4.95 2.32 2.50 5/16 6 10 AWG-350 kcmil 5.86 2.32 2.50 5/16 8 10 AWG-350 kcmil 7.68 2.32 2.50 5/16 10 10 AWG-350 kcmil 9.50 2.32 2.50 5/16 Catalog Number BIBS350-12 BIBS350-14 BIBS600-3 BIBS600-4 BIBS600-5 BIBS600-6 BIBS600-8 BIBS600-10 BIBS600-12 BIBS600-14 BIBS750-3* BIBS750-4* BIBS750-6* BIBS750-8* BIBS750-10* BIBS750-12* BIBS750-14* # of Ports Wire Range (AWG/kcmil) L W H Hex Key 12 10 AWG-350 kcmil 11.32 2.32 2.50 5/16 14 10 AWG-350 kcmil 13.14 2.32 2.50 5/16 3 4 AWG-600 kcmil 4.00 2.38 2.75 3/8 4 4 AWG-600 kcmil 5.28 2.38 2.75 3/8 5 4 AWG-600 kcmil 6.56 2.38 2.75 3/8 6 4 AWG-600 kcmil 7.84 2.38 2.75 3/8 8 4 AWG-600 kcmil 10.41 2.38 2.75 3/8 10 4 AWG-600 kcmil 12.97 2.38 2.75 3/8 12 4 AWG-600 kcmil 15.53 2.38 2.75 3/8 14 4 AWG-600 kcmil 18.09 2.38 2.75 3/8 3 2 AWG-750 kcmil 4.00 2.70 3.00 3/8 4 2 AWG-750 kcmil 5.38 2.70 3.00 3/8 6 2 AWG-750 kcmil 8.13 2.70 3.00 3/8 8 2 AWG-750 kcmil 10.88 2.70 3.00 3/8 10 2 AWG-750 kcmil 13.63 2.70 3.00 3/8 12 2 AWG-750 kcmil 16.38 2.70 3.00 3/8 14 2 AWG-750 kcmil 19.13 2.70 3.00 3/8 NOTE: Only 1 conductor per port allowed. * Not UL Listed. UNITAP™ rated for code conductor only. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-58 BURNDY® TYPE BIBD UNITAP™ Clear Insulated Multiple Tap Connectors Tap connections and in-line splice/reductions are made quickly and easily with the UNITAP™ line of connectors. UL486B Listed. Dual-rated AL9CU for any stranded copper or stranded aluminum applications. 600 Volt, 90° C. Features & Benefits • Oxide inhibitor pre-installed ◊ Inhibits moisture and contaminants from entering the contact area • Range-taking ◊ Reduces number of connectors carried in inventory • Clear Plastisol covered AL6061-T6 aluminum body ◊ Saves time, lowers installation costs, eliminates taping • Clear Plastisol ◊ Allows visual confirmation that conductor is properly inserted MULTI-PORT Double-Sided Entry Catalog Number BIBD4-2 BIBD4-3 BIBD4-4 BIBD4-5 BIBD4-6 BIBD4-8 BIBD2/0-2 BIBD2/0-3 BIBD2/0-4 BIBD2/0-5 BIBD2/0-6 BIBD2/0-8 BIBD2/0-10 BIBD2/0-12 BIBD2/0-14 BIBD250-2 BIBD250-3 BIBD250-4 BIBD250-5 BIBD250-6 BIBD250-8 BIBD250-10 BIBD250-12 BIBD250-14 BIBD350-2 BIBD350-3 # of Ports Wire Range (AWG/kcmil) W L H Hex Key 2 14 AWG-4 Str 1.50 1.08 1.25 1/8 3 14 AWG-4 Str 1.50 1.51 1.25 1/8 4 14 AWG-4 str 1.50 1.95 1.25 1/8 5 14 AWG-4 Str 1.50 2.39 1.25 1/8 6 14 AWG-4 Str 1.50 2.83 1.25 1/8 8 14 AWG-4 str 1.50 3.71 1.25 1/8 2 14 AWG-2/0 Str 1.56 1.52 1.38 3/16 3 14 AWG-2/0 Str 1.56 2.19 1.38 3/16 4 #14-2/0 Str 1.56 2.86 1.38 3/16 5 #14-2/0 Str 1.56 3.53 1.38 3/16 6 14 AWG-2/0 Str 1.56 4.20 1.38 3/16 8 14 AWG-2/0 Str 1.56 5.55 1.38 3/16 10 14 AWG-2/0 Str 1.56 6.89 1.38 3/16 12 14 AWG-2/0 Str 1.56 8.24 1.38 3/16 14 14 AWG-2/0 Str 1.56 9.58 1.38 3/16 2 10 AWG-250 kcmil 2.64 2.03 2.13 5/16 3 10 AWG-250 kcmil 2.64 2.97 2.13 5/16 4 10 AWG-250 kcmil 2.64 3.91 2.13 5/16 5 10 AWG-250 kcmil 2.64 4.84 2.13 5/16 6 10 AWG-250 kcmil 2.64 5.78 2.13 5/16 8 10 AWG-250 kcmil 2.64 7.66 2.13 5/16 10 10 AWG-250 kcmil 2.64 9.53 2.13 5/16 12 10 AWG-250 kcmil 2.64 11.41 2.13 5/16 14 10 AWG-250 kcmil 2.64 13.29 2.13 5/16 2 10 AWG-350 kcmil 3.00 2.22 2.50 5/16 3 10 AWG-350 kcmil 3.00 3.13 2.50 5/16 Catalog Number BIBD350-4 BIBD350-5 BIBD350-6 BIBD350-8 BIBD350-10 BIBD350-12 BIBD350-14 BIBD600-2 BIBD600-3 BIBD600-4 BIBD600-5 BIBD600-6 BIBD600-8 BIBD600-10 BIBD600-12 BIBD600-14 BIBD750-2* BIBD750-3* BIBD750-4* BIBD750-6* BIBD750-8* BIBD750-10* BIBD750-12* BIBD750-14* # of Ports Wire Range (AWG/kcmil) W L H Hex Key 4 10 AWG-350 kcmil 3.00 4.04 2.50 5/16 5 10 AWG-350 kcmil 3.00 4.95 2.50 5/16 6 10 AWG-350 kcmil 3.00 5.86 2.50 5/16 8 10 AWG-350 kcmil 3.00 7.68 2.50 5/16 10 10 AWG-350 kcmil 3.00 9.50 2.50 5/16 12 10 AWG-350 kcmil 3.00 11.32 2.50 5/16 14 10 AWG-350 kcmil 3.00 13.14 2.50 5/16 2 4 AWG-600 kcmil 3.00 2.56 2.75 3/8 3 4 AWG-600 kcmil 3.00 3.77 2.75 3/8 4 4 AWG-600 kcmil 3.00 4.97 2.75 3/8 5 4 AWG-600 kcmil 3.00 6.17 2.75 3/8 6 4 AWG-600 kcmil 3.00 7.37 2.75 3/8 8 4 AWG-600 kcmil 3.00 9.78 2.75 3/8 10 4 AWG-600 kcmil 3.00 12.97 2.75 3/8 12 4 AWG-600 kcmil 3.00 15.53 2.75 3/8 14 4 AWG-600 kcmil 3.00 18.09 2.75 3/8 2 2 AWG-750 kcmil 3.38 2.87 3.00 3/8 3 2 AWG-750 kcmil 3.38 4.25 3.00 3/8 4 2 AWG-750 kcmil 3.38 5.63 3.00 3/8 6 2 AWG-750 kcmil 3.38 8.37 3.00 3/8 8 2 AWG-750 kcmil 3.38 11.13 3.00 3/8 10 2 AWG-750 kcmil 3.38 13.87 3.00 3/8 12 2 AWG-750 kcmil 3.38 16.63 3.00 3/8 14 2 AWG-750 kcmil 3.38 19.37 3.00 3/8 NOTE: Only 1 conductor per port allowed. * Not UL Listed. UNITAP™ rated for code conductor only. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE BIBS-MT, BIBD-MT A-59 UNITAP™ Clear Insulated Multiple Tap Connectors Mounting Version Fig. 1 The BIBS-MT and BIBD-MT series UNITAP™ offer the same multi-port capabilities as the standard UNITAP™ connectors except these -MT types are provided with two isolated mounting holes at both ends of the connector for direct mounting to a trough, gutter or wireway. They will accommodate up to standard 1/4" hardware. Fig. 2 MULTI-PORT Single-Sided Entry Catalog Number Fig. # # of Ports MULTI-PORT Double-Sided Entry Wire Range (AWG/kcmil) L W H Hex Key Catalog Number Fig. # # of Ports Wire Range (AWG/kcmil) L W H Hex Key BIBS2/04MT 1 4 #14 -2/0 Str 4.20 1.25 1.50 3/16 BIBD2/04MT 2 4 14 AWG-2/0 AWG 4.20 1.56 1.50 3/16 BIBS2/06MT 1 6 #14 -2/0 Str 5.54 1.25 1.50 3/16 BIBD2/06MT 2 6 14 AWG-2/0 AWG 5.54 1.56 1.50 3/16 BIBS2/08MT 1 8 14 AWG-2/0 Str 6.89 1.25 1.50 3/16 BIBD2/08MT 2 8 14 AWG-2/0 AWG 6.89 1.56 1.50 3/16 BIBS2/010MT 1 10 14 AWG-2/0 Str 8.23 1.25 1.50 3/16 BIBD2/010MT 2 10 14 AWG-2/0 AWG 8.23 1.56 1.50 3/16 BIBS2/012MT 1 12 14 AWG-2/0 Str 9.58 1.25 1.50 3/16 BIBD2/012MT 2 12 14 AWG-2/0 AWG 9.58 1.56 1.50 3/16 BIBS2504MT 1 4 10 AWG-250 kcmil 5.78 1.95 2.63 5/16 BIBD2504MT 2 4 10 AWG-250 kcmil 5.78 2.64 2.26 5/16 BIBS2506MT 1 6 10 AWG-250 kcmil 7.65 1.95 2.63 5/16 BIBD2506MT 2 6 10 AWG-250 kcmil 7.65 2.64 2.26 5/16 BIBS2508MT 1 8 10 AWG-250 kcmil 9.53 1.95 2.63 5/16 BIBD2508MT 2 8 10 AWG-250 kcmil 9.53 2.64 2.26 5/16 BIBS25010MT 1 10 10 AWG-250 kcmil 11.41 1.95 2.63 5/16 BIBD25010MT 2 10 10 AWG-250 kcmil 11.41 2.64 2.26 5/16 BIBS25012MT 1 12 10 AWG-250 kcmil 13.28 1.95 2.63 5/16 BIBD25012MT 2 12 10 AWG-250 kcmil 13.28 2.64 2.26 5/16 BIBS3504MT 1 4 10 AWG-350 kcmil 5.86 2.19 2.63 5/16 BIBD3504MT 2 4 10 AWG-350 kcmil 5.86 3.00 2.63 5/16 BIBS3506MT 1 6 10 AWG-350 kcmil 7.68 2.19 2.63 5/16 BIBD3506MT 2 6 10 AWG-350 kcmil 7.68 3.00 2.63 5/16 BIBS3508MT 1 8 10 AWG-350 kcmil 9.50 2.19 2.63 5/16 BIBD3508MT 2 8 10 AWG-350 kcmil 9.50 3.00 2.63 5/16 BIBS35010MT 1 10 10 AWG-350 kcmil 11.32 2.19 2.63 5/16 BIBD35010MT 2 10 10 AWG-350 kcmil 11.32 3.00 2.63 5/16 BIBS35012MT 1 12 10 AWG-350 kcmil 13.41 2.19 2.63 5/16 BIBD35012MT 2 12 10 AWG-350 kcmil 13.41 3.00 2.63 5/16 BIBS6004MT 1 4 4 AWG-600 kcmil 7.84 2.25 2.88 3/8 BIBD6004MT 2 4 4 AWG-600 kcmil 7.84 3.00 2.88 3/8 BIBS6006MT 1 6 4 AWG-600 kcmil 10.41 2.25 2.88 3/8 BIBD6006MT 2 6 4 AWG-600 kcmil 10.41 3.00 2.88 3/8 BIBS6008MT 1 8 4 AWG-600 kcmil 12.97 2.25 2.88 3/8 BIBD6008MT 2 8 4 AWG-600 kcmil 12.97 3.00 2.88 3/8 BIBS60010MT 1 10 4 AWG-600 kcmil 15.53 2.25 2.88 3/8 BIBD60010MT 2 10 4 AWG-600 kcmil 15.53 3.00 2.88 3/8 BIBS60012MT 1 12 4 AWG-600 kcmil 18.09 2.25 2.88 3/8 BIBD60012MT 2 12 4 AWG-600 kcmil 18.09 3.00 2.88 3/8 UNITAP™ rated for code conductor only. UNITAP™ rated for code conductor only. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-60 BURNDY® UV RATED BLACK UNITAP™ Features & Benefits • UV Rated Plastisol covered AL6061-T6 aluminum body saves time by eliminating the need for taping. • Oxide inhibitor pre-installed inhibits moisture and contaminants from entering the contact area. • Range-taking capability reduces the number of connectors carried in inventory. • UL486B Listed, AL9CU, 600V 90°C. UNITAP™ 600V, 90°C Catalog Number 1PL42 1PLO42 1PL2/02 1PLO2/02 1PL2502 1PLO2502 1PL3502 1PLO3502 1PL6002 1PLO6002 1PBS2 # of Ports Wire Range (AWG/kcmil) L W H Hex Key Torque 2 2 2 2 2 2 2 2 2 2 2 14 AWG-4 AWG 14 AWG-4 AWG 14 AWG-2/0 AWG 14 AWG-2/0 AWG 10 AWG-250 kcmil 10 AWG-250 kcmil 10 AWG-350 kcmil #10-350 kcmil 10 AWG-600 kcmil 4 AWG-600 kcmil 14 AWG-2 AWG 1.08 1.08 1.52 1.52 2.03 2.03 2.22 2.22 2.72 2.72 2.38 1.16 1.50 1.40 1.56 2.07 2.64 2.32 3.00 2.38 3.00 0.75 1.25 1.25 1.38 1.38 2.13 2.13 2.50 2.50 2.75 2.75 1.22 1/8 1/8 3/16 3/16 5/16 5/16 5/16 5/16 3/8 3/8 5/32 45 45 120 120 275 275 275 275 375 375 45 1PBS1/0 2 14 AWG-1/0 2.91 0.91 1.38 3/16 120 1PBS250 1PBS350 1PBS500 1PL43 1PL44 1PL2/03 1PL2503 1PLD43 1PLD44 1PLD2/02 1PLD2/03 1PLD2/04 1PLD2/06 1PLD2502 1PLD2503 1PLD2504 1PLD2506 1PLD3502 1PLD3503 1PLD3504 1PLD3506 1PLD3508 1PLD6002 1PLD6003 1PLD6004 1PLD6005 1PLD6006 1PLD6008 2 2 2 3 4 3 3 3 4 2 3 4 6 2 3 4 6 2 3 4 6 8 2 3 4 5 6 8 10 AWG-250 kcmil 10 AWG-350 kcmil 6 AWG-500 kcmil 14 AWG-4 AWG 14 AWG-4 AWG 14 AWG-2/0 AWG 10 AWG-250 kcmil 14 AWG-4 AWG 14 AWG-4 AWG 14 AWG-2/0 AWG 14 AWG-2/0 AWG 14 AWG-2/0 AWG 14 AWG-2/0 AWG 10 AWG-250 kcmil 10 AWG-250 kcmil 10 AWG-250 kcmil 10 AWG-250 kcmil 10 AWG-350 kcmil 10 AWG-350 kcmil 10 AWG-350 kcmil 10 AWG-350 kcmil 10 AWG-350 kcmil 4 AWG-600 kcmil 4 AWG-600 kcmil 4 AWG-600 kcmil 4 AWG-600 kcmil 4 AWG-600 kcmil 4 AWG-600 kcmil 4.01 4.63 5.00 1.51 1.95 2.19 2.97 1.51 1.95 1.52 2.19 2.86 4.20 2.03 2.97 3.91 5.78 2.22 3.13 4.04 5.86 7.68 2.72 4.00 5.28 6.56 7.84 10.40 1.19 1.34 1.62 1.25 1.25 1.31 2.07 1.50 1.50 1.56 1.56 1.56 1.56 2.64 2.64 2.64 2.64 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 2.10 2.35 2.62 1.25 1.25 1.38 2.13 1.25 1.25 1.38 1.38 1.38 1.38 2.13 2.13 2.13 2.13 2.50 2.50 2.50 2.50 2.50 2.75 2.75 2.75 2.75 2.75 2.75 5/16 1/3 3/8 1/8 1/8 3/16 1/3 1/8 1/8 1/5 3/16 3/16 3/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 3/8 3/8 3/8 3/8 3/8 3/8 120 275 375 45 45 120 275 45 45 120 120 120 120 275 275 275 275 375 375 375 375 375 375 375 375 375 375 375 1PL = 2 Port Single Sided Entry 1PLO = 2 Port Offset Entry 1PBS = In-line Splice/Reducer 1PL = Multi-Port Single Sided Entry 1PLD = Multi-Port Double Sided Entry UNITAP™ rated for code conductor only. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Mechanical BURNDY® TYPE BWTE A-61 WALL-MOUNTED TERMINATION ENCLOSURES These are three-phase, NEMA 3R (rain-proof), 600 Volt Rated wall mounted termination enclosures. AL9CU Features and Benefits • Manufactured to meet or exceed ANSI C57-12.28 for wall-mounted equipment enclosure integrity • Three-point positive latch mechanism (secured and operated by a half-turn, captive and recessed penta-head bolt) and shielded padlock shackle • Finish meets or exceeds proposed EEI paint specification • Finish is gray, oven cured powder coat • All mounting hardware is 18-8 stainless steel • Aluminum mechanical bar connectors eliminates need for compressions tools, lugs, and bolt assemblies • Aluminum enclosure is lightweight, low maintenance and has excellent corrosion resistance • Ample working space, allowing for easier termination with a removeable swinging door • All-welded construction: welds and seams are ground smooth Dimensions UL Listed Amp Rating Catalog Number Conductor Range (AWG) Number of Conductors per phase W D H Door Opening Copper Aluminum BWTE21-500 10 - 500 kcmil 21 32.00 16.00 51.00 28.00 3800 3100 BWTE21-750 2 - 750 kcmil 14 32.00 16.00 51.00 28.00 3325 2695 BWTE21-1000 1/0 - 1000 kcmil 14 32.00 16.00 51.00 28.00 3815 3115 Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175 Mechanical A-62 BURNDY® TYPE BPTE PAD-MOUNTED TERMINATION ENCLOSURES These are three-phase, NEMA 3R (rain-proof), 600 Volt Rated pad mounted termination enclosures. Features and Benefits • Manufactured to meet or exceed ANSI C57-12.28 for wall-mounted equipment enclosure integrity • Removable swinging doors - doors have stainless steel lift off hinges with stainless steel three point locking handles and recessed stainless steel penta-head bolts for security • Finish is Munsell green, oven cured powder coat • All mounting hardware is 18-8 stainless steel • Aluminum mechanical bar connectors eliminates need for compressions tools, lugs and bolt assemblies • Aluminum enclosure is lightweight, low maintenance and has excellent corrosion resistance • Ample working space, allowing for easier termination with a removeable swinging door • All-welded construction: welds and seams are ground smooth Dimensions UL Listed Amp Rating Catalog Number Conductor Range (AWG) Number of Conductors per phase W D H Door Opening Copper Aluminum BPTE26-500 10 - 500 kcmil 26 36.00 30.00 44.00 30.00 4560 3720 BPTE22-750 2 - 750 kcmil 22 36.00 30.00 44.00 30.00 5225 4235 BPTE20-1000 350 - 1000 kcmil 20 36.00 30.00 44.00 30.00 4905 4005 BPTE14-750 2 - 750 kcmil 14 25.00 24.00 44.00 19.00 3800 3100 Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2014:01:15 16:16:44-05:00 Creator : Adobe Acrobat 9.2.0 Modify Date : 2014:01:18 13:04:02-05:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2014:01:18 13:04:02-05:00 Creator Tool : Adobe Acrobat 9.2.0 Format : application/pdf Document ID : uuid:129b0d41-a186-4731-8455-e6815ce5c933 Instance ID : uuid:9736ef48-858f-47c2-a9b5-a5532ae5e0c2 Producer : Adobe Acrobat 9.2.0 Page Count : 62EXIF Metadata provided by EXIF.tools