SERVICE AND WIRING SHEET Amana Refrigerator 2265591 A
2012-10-25
: Pdf Amana Refrigerator 2265591-A Amana_Refrigerator_2265591-A Amana Appliances
Open the PDF directly: View PDF .
Page Count: 2
SERVICE AND WIRING SHEET
ELECTRICAL SHOCK
HAZARD
Disconnect electrical
power before servicing
Failure to do so can result
in death or electrical shock
PERFORMANCE DATA
*(NORMAL OPERATING CONDITIONS)
SYSTEM PRESURE
(PSIG)
AMB WATTS HIGH SIDE LOW SIDE
70°
°°
°160 ±
±±
± 20 95 ±
±±
± 20 -7 TO 3
90°
°°
°170 ±
±±
± 20 135 ±
±±
± 20 -4 TO 3
110°
°°
°190 ±
±±
± 20 185 ±
±±
± 20 -2 TO 4
SERVICE INFORMATION ( 2265592 REV.A)
1. COMPRESSOR SUCTION AND PROCESS STUBS MAY NOT BE INTERCHANGED UNLESS INDICATED BY **.
2. REFRIGERANT CHARGE MUST BE APPLIED TO HIGH SIDE ONLY.
3. ICE MAKER AND WATER VALVE NOT ORIGINAL EQUIPMENT ON ALL MODELS.
4. CAUTION: ICE MAKER CYCLE MUST BE INITIATED ELECTRICALLY. DO NOT TRY TO MANUALLY START CYCLE.
5. SERVICE DEFROST BIMETALS - 50°F OPEN.
6. DEFROST TIMER MAY CONTAIN A CAPACITOR IN SERIES WITH MOTOR. DO NOT CONTINUITY TEST WHEN
CHECKING FOR FAILED TIMER MOTOR. INSTEAD, ENERGIZE TIMER AND LISTEN FOR GEAR MOVEMENT.
7. PART NUMBER CAN BE FOUND ON THE COMPONENT.
CUBIC FEET
18’CD CB 18’ CD CB WATTAGE RESISTANCE
SERVICEABLE PARTS Embraco Matsushita 120V 120V
COMPRESSOR 2216049 2217634
RUN WINDINGS 1-6
START WINDINGS 3-11
PTC RELAY
OVERLOAD 2225930
(Combo Device) 2225929
(Combo Device)
RUN CAPACITOR See Note 7
THERMOSTAT 2201754
DEFROST TIMER ∗∗ 2288371
ADAPTIVE DEFROST ∗∗(OPT) 2288160
DEFROST HEATER 2176942 450-500 28-32
DEFROST BI-METAL 2183073
CONDENSER FAN 2188875
EVAPORATOR FAN 2201212/2262070 5-10
∗∗ PRIMARY SOURCE PART NUMBER
STEPS TO ENTER ELECTRONIC DEFROST CONTROL TEST MODE (IF APPLICABLE)
OPTION #1 (BI-METAL CLOSED) OPTION #2 (BI-METAL CLOSED)
STEPS STEPS
#1 - POWER OFF TO REFRIGERATOR FOR AT LEAST 30 SECONDS #1 - THERMOSTAT OFF 15 SECONDS
#2 - THERMOSTAT OFF #2 - THERMOSTAT ON 5 SECONDS
#3 - POWER ON TO REFRIGERATOR (REPEAT STEPS 1 & 2 TWO MORE TIMES)
#3 - THERMOSTAT OFF
ENTER TEST MODE
IN 3 - 8 SECONDS, CONTROL WILL TURN ON DEFROST HEATER. DEFROST HEATER WILL TURN ON FOR 21 MINUTES OR UNTIL BI-METAL OPENS. TO TERMINATE TEST EARLY, REMOVE
POWER FROM REFRIGERATOR.
NOTE: IF OPTION #2 DOES NOT WORK, TRY OPTION #1 BEFORE REPLACING CONTROL. ALWAYS CHECK CONNECTIONS BEFORE REPLACING CONTROL.
HELPFUL HINT: UPON ENTERING TEST MODE, A RELAY TURNS OFF THE COMPRESSOR AND TURNS ON THE DEFROST TIMER. LISTEN FOR THE RELAY TO CLICK. IF RELAY CLICKS
ONCE UPON ENTERING TEST MODE, CHECK FOR DEFROST HEAT. IF RELAY CLICKS TWICE, CHECK FOR BI-METAL OPEN.
IF BI-METAL IS BY-PASSED FOR TESTING (IF APPLICABLE), DO NOT OVERHEAT EVAPORATOR AREA.
SERVICE & WIRING
SHEET NO. SERVICE & WIRING
SHEET NO.
2265591-A 2265591-A
(OIL COOLER IS OPTIONAL)
EMBRACO
WARNING
2265591-
A
* Normal operating conditions are viewed when the air and
temperature controls are at mid-setting, freezer section 0 to -5°F and
unit is cycling.
NOTE: Watt and pressure readings will vary and are influenced by
the existing condition of the appliance, such as iced-up evaporator,
condition of condenser, defrost cycle, pull-down time and customer
use.
EGY SERIES OIL COOLER
DISCHARGE
SUCTION TUBE
PROCESS TUBE
WARNING
MATSUSHITA
D
G
S
ERIE
S
DISCHARGE
EMBRACO
EM
S
ERIE
S
SUCTION
TUBE
PROCESS
TUBE