SERVICE AND WIRING SHEET Amana Refrigerator 2265591 A
2012-10-25
: Pdf Amana Refrigerator 2265591-A Amana_Refrigerator_2265591-A Amana Appliances
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
SERVICE AND WIRING SHEET 2265591-A Failure to do so can result ELECTRICAL SHOCK Disconnect electrical HAZARD power before servicing in death or electrical shock WARNING PERFORMANCE DATA *(NORMAL OPERATING CONDITIONS) SYSTEM PRESURE (PSIG) AMB WATTS HIGH SIDE LOW SIDE -7 TO 3 70°° 160 ± 20 95 ± 20 -4 TO 3 90°° 170 ± 20 135 ± 20 -2 TO 4 110°° 190 ± 20 185 ± 20 * Normal operating conditions are viewed when the air and temperature controls are at mid-setting, freezer section 0 to -5°F and unit is cycling. NOTE: Watt and pressure readings will vary and are influenced by the existing condition of the appliance, such as iced-up evaporator, condition of condenser, defrost cycle, pull-down time and customer use. (OIL COOLER IS OPTIONAL) EMBRACO SUCTION TUBE PROCESS TUBE SERVICE INFORMATION ( 2265592 REV.A) 1. 2. 3. 4. 5. 6. COMPRESSOR SUCTION AND PROCESS STUBS MAY NOT BE INTERCHANGED UNLESS INDICATED BY **. REFRIGERANT CHARGE MUST BE APPLIED TO HIGH SIDE ONLY. ICE MAKER AND WATER VALVE NOT ORIGINAL EQUIPMENT ON ALL MODELS. CAUTION: ICE MAKER CYCLE MUST BE INITIATED ELECTRICALLY. DO NOT TRY TO MANUALLY START CYCLE. SERVICE DEFROST BIMETALS - 50°F OPEN. DEFROST TIMER MAY CONTAIN A CAPACITOR IN SERIES WITH MOTOR. DO NOT CONTINUITY TEST WHEN CHECKING FOR FAILED TIMER MOTOR. INSTEAD, ENERGIZE TIMER AND LISTEN FOR GEAR MOVEMENT. 7. PART NUMBER CAN BE FOUND ON THE COMPONENT. DISCHARGE EGY SERIES OIL COOLER CUBIC FEET 18’CD CB SERVICEABLE PARTS Embraco COMPRESSOR RUN WINDINGS START WINDINGS PTC RELAY OVERLOAD RUN CAPACITOR THERMOSTAT DEFROST TIMER ∗∗ ADAPTIVE DEFROST ∗∗(OPT) DEFROST HEATER DEFROST BI-METAL CONDENSER FAN EVAPORATOR FAN ∗∗ PRIMARY SOURCE PART NUMBER 2216049 18’ CD CB WATTAGE RESISTANCE Matsushita 120V 120V 2217634 1-6 3-11 2225930 2225929 (Combo Device) (Combo Device) See Note 7 2201754 2288371 2288160 2176942 2183073 2188875 2201212/2262070 450-500 28-32 5-10 STEPS TO ENTER ELECTRONIC DEFROST CONTROL TEST MODE (IF APPLICABLE) OPTION #1 (BI-METAL CLOSED) STEPS #1 - POWER OFF TO REFRIGERATOR FOR AT LEAST 30 SECONDS #2 - THERMOSTAT OFF #3 - POWER ON TO REFRIGERATOR OPTION #2 (BI-METAL CLOSED) STEPS #1 - THERMOSTAT OFF 15 SECONDS #2 - THERMOSTAT ON 5 SECONDS (REPEAT STEPS 1 & 2 TWO MORE TIMES) #3 - THERMOSTAT OFF ENTER TEST MODE IN 3 - 8 SECONDS, CONTROL WILL TURN ON DEFROST HEATER. DEFROST HEATER WILL TURN ON FOR 21 MINUTES OR UNTIL BI-METAL OPENS. TO TERMINATE TEST EARLY, REMOVE POWER FROM REFRIGERATOR. NOTE: IF OPTION #2 DOES NOT WORK, TRY OPTION #1 BEFORE REPLACING CONTROL. ALWAYS CHECK CONNECTIONS BEFORE REPLACING CONTROL. HELPFUL HINT: UPON ENTERING TEST MODE, A RELAY TURNS OFF THE COMPRESSOR AND TURNS ON THE DEFROST TIMER. LISTEN FOR THE RELAY TO CLICK. IF RELAY CLICKS ONCE UPON ENTERING TEST MODE, CHECK FOR DEFROST HEAT. IF RELAY CLICKS TWICE, CHECK FOR BI-METAL OPEN. WARNING IF BI-METAL IS BY-PASSED FOR TESTING (IF APPLICABLE), DO NOT OVERHEAT EVAPORATOR AREA. MATSUSHITA PROCESS TUBE DG SERIES EMBRACO SUCTION TUBE DISCHARGE EM SERIES SERVICE & WIRING SHEET NO. SERVICE & WIRING SHEET NO. 2265591-A 2265591-A 18-Mar-2005 11:35:34
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Producer : Acrobat Distiller 4.0 for Windows Creator : Microsoft Word 8.0 Modify Date : 2005:12:21 08:36:49 Author : Refrigeration Technology Title : SERVICE AND WIRING SHEET Create Date : 2005:12:21 08:24:09 Page Count : 2 Page Mode : UseNoneEXIF Metadata provided by EXIF.tools