Amana Technical Information³Refrigerator
April 1997 1 RT1300024 Rev0
SCD22TB P1303511W
Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing
or repair of this refrigerator.
Refer to Service Manual RS1000001 for installation, disassembly, ice maker, safety, testing, and troubleshooting
information.
CAUTION
!
All safety information must be followed as provided in Service Manual RS1000001.
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to refrigerator before servicing, unless
testing requires power. Wires removed during disassembly must be replaced on proper terminals to insure correct
earthing and polarization.
Model SCD22TB
Capacity 22.14 cu ft
Electrical
requirements
separate circuit
115 VAC 60 Hz
15 amps
Refrigerant type R134a
Width
without side
extrusions
35.75
Depth
without handle
includes door
extrusions
29.75
Height
including top
hinge cap
68.5
No Load Performance Controls in Normal Position
Kw/24hr 0.4 Percent Run Time
10% Cycles/24 hr
25%
Refrigerator Center
Compartment Food
Average
Temperature 3 F
Freezer
Compartment Food
Average
Temperature 3 F
Ambient F65 90 110 65 90 110 65 90 110 65 90 110 65 90 110
22 Cu Ft 1. 2. 4. 37. 50. 100. 37. 33. 0. 38. 40. 40. 1. 2. 2.
Temperature Relationship Test Chart
T-1 Outlet
3 F T-2 Inlet
3 F T-3 Suction Line
7 F Average Total
Wattage 10%
Suction
Pressure
2 PSIG Head Pressure
5 PSIG
Ambient F 65 90 65 90 65 90 65 90 65 90 65 110
22 Cu Ft -10. -11. -13. -12. 67. 90. 161. 171. 1. 1. 85. 185.
Component Specifications
RT1300024 Rev. 0 2 April 1997
Part Number Component Name Test Procedure
A0282803
Bulb Volt
Watt 115/125 VAC
40 watts
M0360001 Bulb Volt
Watt 115/125 VAC
6 watts
C8931604
Capacitor, compressor run Volt
Capacitance 220 VAC
15 Mfd +10%
-5%
C8931605 Capacitor, auger motor Volt
Capacitance 220 VAC
17 Mfd +10%
-5%
12049702 Compressor Type
BTUH
Volt
Watt
Current
Lock rotor
Full load
Resistance
Run Windings
Start Windings
Fan Cooled, R134a refrigerant
970 BTUH
115 VAC, 60 Hz
176 watts
21.3 amps
1.6 amps
2.60 ohms
4.35 ohms
D7547412
Control, damper Settings
#1
#4
#7
Closing temperatures
47 F
40 F
30 F
C3615024
Control, freezer temperature Settings
#1 in
#1 out
#4 in
#4 out
#7 in
#7 out
Temperatures
21.0 F
4.5 F
13.3 F
-5.9 F
9.8 F
-11.0 F
B2150504
Drier Drier must be changed every time the system is opened for testing or compressor
replacement.
Desiccant (20) 8 x 12 4AXH - 7 M>S> -Grams
10882105 Heater, cavity Volt
Watt
Resistance
115 VAC
5 7.5% watts
1.89 7.5% ohms
12049801 Heater, evaporator Volt
Wattage
Resistance
115 VAC
450 5% watts
29 5% ohms
Component Specifications
April 1997 3 RT1300024 Rev0
Part Number Component Name Test Procedure
10114804
Motor, auger Volt
Rotation (facing shaft)
RPM
Watt
Bimetal Cut-out
Opens
Closes
115 VAC, 60 Hz
Power to blue and white leads is clockwise
Power to white and orange leads is
counterclockwise
13 17 RPM
165 watts
266 9 C
1185 9 C
10884501
Motor, condenser Volt
Rotation (facing end opposite shaft)
RPM
Watt
Current
Resistance
115 VAC, 60 Hz
Clockwise
1300 RPM
10.0 watts
0.15 amps
220 10% ohms
10513803
Motor, evaporator fan Volt
Rotation (facing end opposite shaft)
RPM
Watt
115 VAC, 60 Hz
Clockwise
2500 RPM
12 15% watts
10377015
Overload, 4TM Volt
Ult. trip amps @ 158°F (70°C)
Close temperature
Open temperature
Short time trip (seconds)
Short time trip (amps @77°F
25°C))
115 VAC
3.51 amps
142°F (61°C) ±9°
257°F (125°C) ±5°
10 seconds 5
14 amps
10097202
12
3Relay, ptc Resistance
With power off check:
Across terminals 2 & 3
Shorted
Open
312 ohms
0 ohms
Very high or infinite ohms
C3680306
Switch, auger motor interrupt Type
Volt
Current
DPST, NO
125/250 VAC
5/2.5 amps
10166101 Switch, cavity light Type
Volt
Current
SPDT
125 VAC
4 amps
10166103 Switch, crushed/cubed Type
Volt
Current
SPST
250 VAC
6 amps
C3680304
Switch, light Type
Volt
Current
DPST
125/250 VAC
5/2.5 amps
Component Specifications
RT1300024 Rev. 0 4 April 1997
Part Number Component Name Test Procedure
10533001
10533002
10533003
Switch, limit and dispensing arms Type
Volt
Current
SPSP, NO
125/250 VAC
10 amps
12017816
Thermostat Volt
Watt
Current
Resistance across terminals
Above 48° ±5°F
Below 15° ±7°F
Between 48° ±5°F and
15° ±7°F
120/240 VAC
1000 watts
10/5 amps
Open
Closed
Will stay in current state (either open or
closed) until either 48° ±6°F or 15° ±8°F is
reached.
10530702
Timer, defrost Volt
Defrost period (minutes)
Defrost cycle (hours)
120 VAC, 60 Hz
33 3.6
8
D7742204
Valve, water Volt
Watt
Water pressure (inlet)
Max
Min
Fill rate
120 VAC, 60 Hz
20 watts/per coil
120 PSI
20 PSI
140 ±10 CC's at 7.5 seconds
Schematic Diagram
April 1997 5 RT1300024 Rev0
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to refrigerator before servicing, unless
testing requires power. Wires removed during disassembly must be replaced on proper terminals to insure correct
earthing and polarization.
DANGER
High Voltage
!
SCD22TB P1303511W
Wiring Diagram
RT1300024 Rev. 0 6 April 1997
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to refrigerator before servicing, unless
testing requires power. Wires removed during disassembly must be replaced on proper terminals to insure correct
earthing and polarization.