Amana Refrigerator SCD22TB
2012-10-25
: Pdf Amana Refrigerator Scd22Tb Amana_Refrigerator_SCD22TB Amana Appliances
Open the PDF directly: View PDF .
Page Count: 6
Download | |
Open PDF In Browser | View PDF |
Amana Technical Information³Refrigerator SCD22TB P1303511W • Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this refrigerator. • Refer to Service Manual RS1000001 for installation, disassembly, ice maker, safety, testing, and troubleshooting information. ! CAUTION All safety information must be followed as provided in Service Manual RS1000001. ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to refrigerator before servicing, unless testing requires power. Wires removed during disassembly must be replaced on proper terminals to insure correct earthing and polarization. Model Capacity Electrical requirements separate circuit Refrigerant type Width without side extrusions Depth without handle includes door extrusions Height including top hinge cap SCD22TB 22.14 cu ft 115 VAC 60 Hz 15 amps R134a 35.75 29.75 68.5 No Load Performance Controls in Normal Position Ambient F 22 Cu Ft Kw/24hr 0.4 65 90 110 1. 2. 4. Percent Run Time 10% 65 90 110 37. 50. 100. Refrigerator Center Compartment Food Average Temperature 3 F 65 90 110 38. 40. 40. Cycles/24 hr 25% 65 90 110 37. 33. 0. Freezer Compartment Food Average Temperature 3 F 65 90 110 1. 2. 2. Temperature Relationship Test Chart T-1 Outlet 3 F Ambient F 65 22 Cu Ft -10. April 1997 T-2 Inlet 3 F 90 -11. 65 -13. 90 -12. T-3 Suction Line 7 F 65 90 Average Total Wattage 10% 65 90 67. 161. 90. 1 171. Suction Pressure 2 PSIG 65 90 Head Pressure 5 PSIG 65 110 1. 1. 85. 185. RT1300024 Rev0 Component Specifications Part Number A0282803 Component Name Bulb Test Procedure Volt Watt 115/125 VAC 40 watts M0360001 Bulb Volt Watt 115/125 VAC 6 watts C8931604 Capacitor, compressor run Volt Capacitance 220 VAC 15 Mfd +10% -5% C8931605 Capacitor, auger motor Volt Capacitance 220 VAC 17 Mfd +10% -5% 12049702 Compressor Type BTUH Volt Watt Current Lock rotor Full load Resistance Run Windings Start Windings Settings #1 #4 #7 Fan Cooled, R134a refrigerant 970 BTUH 115 VAC, 60 Hz 176 watts D7547412 Control, damper C3615024 Control, freezer temperature B2150504 Drier 21.3 amps 1.6 amps 2.60 ohms 4.35 ohms Closing temperatures 47F 40F 30F Temperatures Settings 21.0F #1²in 4.5F #1²out 13.3F #4²in -5.9F #4²out 9.8F #7²in -11.0F #7²out Drier must be changed every time the system is opened for testing or compressor replacement. Desiccant (20) 8 x 12 4AXH - 7 M>S> -Grams 10882105 Heater, cavity Volt Watt Resistance 115 VAC 5 7.5% watts 1.89 7.5% ohms 12049801 Heater, evaporator Volt Wattage Resistance 115 VAC 450 5% watts 29 5% ohms RT1300024 Rev. 0 2 April 1997 Component Specifications Part Number 10114804 Component Name Motor, auger Test Procedure Volt Rotation (facing shaft) RPM Watt Bimetal Cut-out Opens Closes Volt Rotation (facing end opposite shaft) RPM Watt Current Resistance 115 VAC, 60 Hz Power to blue and white leads is clockwise Power to white and orange leads is counterclockwise 13²17 RPM 165² watts 266 9C 1185 9C 115 VAC, 60 Hz Clockwise 1300 RPM 10.0 watts 0.15 amps 220 10% ohms 10884501 Motor, condenser 10513803 Motor, evaporator fan Volt Rotation (facing end opposite shaft) RPM Watt 115 VAC, 60 Hz Clockwise 2500 RPM 12 15% watts 10377015 Overload, 4TM Volt Ult. trip amps @ 158°F (70°C) Close temperature Open temperature Short time trip (seconds) Short time trip (amps @77°F 25°C)) 115 VAC 3.51 amps 142°F (61°C) ±9° 257°F (125°C) ±5° 10 seconds 5 14 amps Relay, ptc Resistance With power off check: Across terminals 2 & 3 Shorted Open 3²12 ohms 0 ohms Very high or infinite ohms 10097202 3 1 2 C3680306 Switch, auger motor interrupt Type Volt Current DPST, NO 125/250 VAC 5/2.5 amps 10166101 Switch, cavity light Type Volt Current SPDT 125 VAC 4 amps 10166103 Switch, crushed/cubed Type Volt Current SPST 250 VAC 6 amps C3680304 Switch, light Type Volt Current DPST 125/250 VAC 5/2.5 amps April 1997 3 RT1300024 Rev0 Component Specifications Part Number 10533001 10533002 10533003 Component Name Switch, limit and dispensing arms Test Procedure Type Volt Current 12017816 Thermostat Volt Watt Current Resistance across terminals Above 48° ±5°F Below 15° ±7°F Between 48° ±5°F and 15° ±7°F 120/240 VAC 1000 watts 10/5 amps SPSP, NO 125/250 VAC 10 amps Open Closed Will stay in current state (either open or closed) until either 48° ±6°F or 15° ±8°F is reached. 10530702 Timer, defrost Volt Defrost period (minutes) Defrost cycle (hours) 120 VAC, 60 Hz 33 3.6 8 D7742204 Valve, water Volt Watt Water pressure (inlet) Max Min Fill rate 120 VAC, 60 Hz 20 watts/per coil RT1300024 Rev. 0 4 120 PSI 20 PSI 140 ±10 CC's at 7.5 seconds April 1997 Schematic Diagram ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to refrigerator before servicing, unless testing requires power. Wires removed during disassembly must be replaced on proper terminals to insure correct earthing and polarization. ! DANGER High Voltage SCD22TB April 1997 P1303511W 5 RT1300024 Rev0 Wiring Diagram ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to refrigerator before servicing, unless testing requires power. Wires removed during disassembly must be replaced on proper terminals to insure correct earthing and polarization. SCD22TB RT1300024 Rev. 0 P1303511W 6 April 1997
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.1 Linearized : No Page Count : 6 Create Date : 1997:08:26 10:49:50 Producer : Acrobat Distiller 3.0 for WindowsEXIF Metadata provided by EXIF.tools