A+CLASS™ OCCUPANCY SENSOR WITH INTELLiDAPT DUAL TECH: PASSIVE INFRARED AND ULTRASONIC Project Information Features • Occupancy Sensor (OS) for A+CLASS™ energy management lighting and control system • IntelliDAPT self-adaptive technology—no manual adjustment required • All-digital dual technology (ultrasonic [US] and passive infrared [PIR]) sensor • Non-volatile memory for sensor settings • Ceiling Mount • 500–2,000 square-foot approximate coverage area • One Occupancy Sensor supplied standard, two optional • A+CLASS™ Plug-and-Play Quick to Install™ (QTI) connector standard • Includes 50’ of low voltage, color coded plug-and-play CAT5 cable • UL and cUL listed when ordered as part of a complete A+Class™ System. • 5-year warranty when ordered as part of the complete A+CLASS™ lighting and controls energy management system Project Name Type Catalog No. Date OVERVIEW The A+CLASS™ APCS-OS occupancy sensor ships standard, one per classroom, as part of the A+CLASS™ energy management lighting and control system. APCS-OS combines ultrasonic (US) and passive infrared (PIR) technologies to turn lighting on and off based on occupancy. This dual technology provides accurate turn-ons while virtually eliminating false-offs. This sensor features patented IntelliDAPT technology, which makes all the sensor adjustments automatically. Throughout the product’s lifespan, smart software analyzes the controlled area and makes digital adjustments to sensitivity and timer settings. Occupancy sensors with IntelliDAPT provide a maintenance-free “Install and Forget” operation. FEATURES and BENEFITS IntelliDAPT technology — Sensor automatically determines the ideal setting for an area — E xcellent false trip immunity (for improved accuracy) — No manual sensitivity and timer adjustments required All-digital dual technology (ultrasonic [US] and passive infrared — S uperior US minor-motion detection with excellent PIR long [PIR]) sensor range majormotion detection — Non-volatile memory for sensor settings — Learned and adjusted settings will not be lost during power outages — Optional RP flying leads (RP) for connection to HVAC if desired Plug & Play Quick to Install™ (QTI) connector — Dramatically reduces installation costs by removing the time consuming process of manually wiring a sensor to a power pack — Easy to install; fast and efficient; no cutting, stripping, or wire nuts required A+CLASS™ System Component When ordered as part of the A+CLASS™ system, 50’ of low voltage, color coded CAT5 plugand-play cable is provided for return to the Classroom Control Module (CCM). — Provides a maintenance-free “Install and Forget” operation. Example: APCS-2-277-TLC1-02-DDZ2 A+CLASS™ SYSTEM Ordering Information APCS — — No. of ROWS 2 Two 3 Three 4 Four — VOLTAGE 120 120V 277 277V SYSTEM APCS A+CLASS TEACHER STATION TLC General, AV, Study Time AVD General, AV Dimming, Study Time1, 2, 3 GDM General (manually dimmed), AV, Study Time1, 2, 3 AGD General (manually dimmed), AV (manually dimmed), Study Time1, 2, 3 TCU Custom Teacher Station (contact factory to specify switches) — NO. OF TEACHER STATIONS 1 One (Std.) 2 Two WHITEBOARD Blank No whiteboard lighting control WT Whiteboard lighting switch included with Teacher Station4 WS Independent whiteboard lighting switch (not in teacher station) WCU Custom Whiteboard Station Requires 0-10V dimming ballast in lighting fixture. Includes additional plug & play cable. Adds Raise/Lower dimming switch to TLC. 3-gang switch station consists of General/ A/V switch, Raise/Lower switch, Study Time switch. 4 WT when used with 2 Teacher Stations will control one whiteboard from 2 locations. 1 2 3 Page 1/2 Rev. 07/31/13 US Patent #8,436,542 — MANUAL CONTROL AT ENTRY Blank One master on/off switch control for all rows and whiteboard NA No master or row controls supplied MC01 One master on/off switch control for all rows and whiteboard MC02 Two master on/off switch controls for all rows and whiteboard (for dual entry/exit points)2 RC One set of on/off independent row switch controls (one switch per row) RC2 Two sets of on/off independent row switch controls (one switch per row) (for dual entry/exit points)2 MRC One master on/off switch control for all rows and white board and one set of on/off independent row switch controls (one switch per row) MRC2 Two master on/off switch controls for all rows and whiteboard and two sets of on/off independent row switch controls (one switch per row) (for dual entry/exit points)2 MCU Custom Master/Row Control Station MCU2 Two Identical Custom Master/Row Control Stations — — DAYLIGHT SENSOR and COntrol Blank None DD Daylight Dimming: Daylight sensor for dimming general mode1, 2 DS Daylight Switching: Daylight sensor for switching general mode off when daylight is sufficient2 OCCUPANCY SENSOR Blank One Occupancy Sensor O2 Two Occupancy Sensors2 RP One Ceiling Mount Occupancy Sensor with RP flying leads RP02 Two Ceiling Mount Occupancy Sensors with RP flying leads OCU Custom Selected Occupancy Sensor (specify) ROOM NO. _ Type Mark (Max 10 characters. Will appear on separate line of order and label.) DAYLIGHT Zones Blank None Z1 Row nearest the window2 Z2 2 Rows nearest the window2 Z3 3 Rows nearest the window2 Z4 4 Rows nearest the window2 OCCUPANCY SENSOR - APCS © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com A+CLASS™ OCCUPANCY SENSOR WITH INTELLiDAPT DUAL TECH: PASSIVE INFRARED AND ULTRASONIC ORDERING When ordered as part of the APCS system, the APCS-OS will ship with one 50’ CAT5 color coded low voltage plug-and-play cable per occupancy sensor (one Occupancy Sensor supplied standard, two optional). The full APCS system includes lighting and controls for a typical classroom application. See the ordering guide for APCS control; lighting selections are found at www.aleralighting.com and are ordered as a separate line item as part of the APCS package. IntelliDAPT Dual Technology with LED Indicator Auto reset from test setting. Self-adjusting timer. Self-adjusting ultrasonic and passive infrared thresholds. Automatic false-on/false-off corrections. Ultrasonic (US) output of 32kHz.Passive infrared (PIR) dual element pyrometer and 12-element cylindrical rugged lens. LED lamp colors provide visual cues indicating occupancy detection method. Red indicates infrared detection. Green indicates ultrasonic motion. Timer timeout Automatic mode: 8–30 min. (self-adjusts based on occupancy) — Test mode: 8 seconds (for an easy check at installation) Coverage, Power and Signal Coverage area of approximately 2,000 square feet. Power input 24 VDC, 33 mA . Power is provided through A+CLASS™ low voltage color coded plug-and-play cable; no line or low voltage additional wiring is required for standard classroom applications. Certifications and Warranty UL and cUL listed with 5 year warranty when purchased as part of the A+CLASS™ energy management classroom lighting and control system Output is 24 VDC active high-logic control signal with short circuit protection Operation APCS-OS is for Indoor use only. Operating temperature: 32o–104o F (0o–40o C). Relative humidity (non-condensing): 0%–95% Recommended MAX mounting height of 12ft. Construction 4.5” diameter, 1.5” height (114 mm diameter, 38mm height). 5.0 oz (142g) weight. Attractive, neutral off white color. Rugged casing, high-impact, injection-molded plastic KJB ABS Cycolac (UL-945VA) flame class rating, UV inhibitors. Mounting base provided. — Quick-To-Install TM wiring standard. Ships with all required components when ordered as part of the A+CLASS™ system, including but not limited to 50’ of color coded, low voltage, plug and play CAT5 cable for return to the A+CLASS™ CCM (Classroom Control Module) Test Date 7/14/00 Page 2/2 Rev. 07/31/13 US Patent #8,436,542 OCCUPANCY SENSOR - APCS © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Instance ID : uuid:373e8c48-db18-324d-ab5e-a5ca9752fa77 Original Document ID : adobe:docid:indd:55caf04d-e579-11de-b3e6-f7083bf19c5f Document ID : xmp.id:C39660E1E0276811822A990F9E94F35A Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:C19660E1E0276811822A990F9E94F35A Derived From Document ID : adobe:docid:indd:55caf04d-e579-11de-b3e6-f7083bf19c5f Derived From Original Document ID: adobe:docid:indd:55caf04d-e579-11de-b3e6-f7083bf19c5f Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2013:07:31 23:55:30-04:00 Create Date : 2013:07:31 23:55:30-04:00 Modify Date : 2013:08:01 23:50:09-04:00 Metadata Date : 2013:08:01 23:50:09-04:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False State : 1 Version : 1.1 Page Count : 2 Creator : Adobe InDesign CS6 (Macintosh) Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools