A+CLASS OCCUPANCY SENSOR WITH INTELLiDAPT
DUAL TECH: PASSIVE INFRARED AND ULTRASONIC
Page 1/2 Rev. 07/31/13
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
US Patent #8,436,542
Catalog No.
Project Name Type
Date
PROJECT INFORMATION
OCCUPANCY SENSOR - APCS
OVERVIEW
The A+CLASS™ APCS-OS occupancy sensor
ships standard, one per classroom, as part of the
A+CLASS™ energy management lighting and
control system. APCS-OS combines ultrasonic
(US) and passive infrared (PIR) technologies to
turn lighting on and o based on occupancy.
This dual technology provides accurate turn-ons
while virtually eliminating false-os. This sensor
features patented IntelliDAPT technology, which
makes all the sensor adjustments automatically.
Throughout the product’s lifespan, smart
software analyzes the controlled area and makes
digital adjustments to sensitivity and timer
settings. Occupancy sensors with IntelliDAPT
provide a maintenance-free “Install and Forget
operation.
FEATURES AND BENEFITS
IntelliDAPT technology
Sensor automatically determines the ideal
setting for an area
Excellent false trip immunity (for improved
accuracy)
No manual sensitivity and timer adjustments
required
Provides a maintenance-free “Install and
Forget” operation.
All-digital dual technology (ultrasonic
[US] and passive infrared
Superior US minor-motion detection with
excellent PIR long [PIR]) sensor range major-
motion detection
— Non-volatile memory for sensor settings
Learned and adjusted settings will not be lost
during power outages
— Optional RP ying leads (RP) for connection
to HVAC if desired
Plug & Play Quick to Install (QTI)
connector
Dramatically reduces installation costs by
removing the time consuming process of
manually wiring a sensor to a power pack
Easy to install; fast and ecient; no cutting,
stripping, or wire nuts required
A+CLASS™ System Component
When ordered as part of the A+CLASS™ system,
50’ of low voltage, color coded CAT5 plug-
and-play cable is provided for return to the
Classroom Control Module (CCM).
FEATURES
Occupancy Sensor (OS) for A+CLASS™ energy
management lighting and control system
IntelliDAPT self-adaptive technology—no manual
adjustment required
All-digital dual technology (ultrasonic [US] and
passive infrared [PIR]) sensor
• Non-volatile memory for sensor settings
• Ceiling Mount
• 500–2,000 square-foot approximate coverage area
One Occupancy Sensor supplied standard, two
optional
A+CLASS™ Plug-and-Play Quick to Install™ (QTI)
connector standard
Includes 50’ of low voltage, color coded
plug-and-play CAT5 cable
UL and cUL listed when ordered as part of a
complete A+Class™ System.
5-year warranty when ordered as part of the
complete A+CLASS™ lighting and controls energy
management system
A+CLASS™ SYSTEM ORDERING INFORMATION
TEACHER STATION
TLC General, AV, Study Time
AVD General, AV Dimming, Study
Time1, 2, 3
GDM General (manually dimmed), AV,
Study Time1, 2, 3
AGD General (manually dimmed),
AV (manually dimmed), Study
Time1, 2, 3
TCU Custom Teacher Station (contact
factory to specify switches)
WHITEBOARD
Blank No whiteboard
lighting control
WT Whiteboard
lighting switch
included with
Teacher Station4
WS Independent
whiteboard
lighting switch
(not in teacher
station)
WCU Custom
Whiteboard
Station
— —
VOLTAGE
120 120V
277 277V
NO. Of ROWS
2Two
3Three
4Four
OCCUPANCY SENSOR
Blank One Occupancy Sensor
O2 Two Occupancy Sensors2
RP One Ceiling Mount
Occupancy Sensor with RP
flying leads
RP02 Two Ceiling Mount
Occupancy Sensors with RP
flying leads
OCU Custom Selected Occupancy
Sensor (specify)
DAYLIGHT SENSOR AND CONTROL
Blank None
DD Daylight Dimming:
Daylight sensor for
dimming general
mode1, 2
DS Daylight Switching:
Daylight sensor for
switching general
mode off when
daylight is sufficient2
ROOM NO.
_Type Mark (Max
10 characters.
Will appear on
separate line of
order and label.)
MANUAL CONTROL AT ENTRY
Blank One master on/off switch control
for all rows and whiteboard
NA No master or row controls supplied
MC01 One master on/off switch control
for all rows and whiteboard
MC02 Two master on/off switch controls
for all rows and whiteboard (for
dual entry/exit points)2
RC One set of on/off independent
row switch controls (one switch
per row)
RC2 Two sets of on/off independent row
switch controls (one switch per
row) (for dual entry/exit points)2
MRC One master on/off switch control
for all rows and white board and
one set of on/off independent
row switch controls (one switch
per row)
MRC2 Two master on/off switch controls
for all rows and whiteboard and
two sets of on/off independent row
switch controls (one switch per
row) (for dual entry/exit points)2
MCU Custom Master/Row Control
Station
MCU2 Two Identical Custom Master/Row
Control Stations
APCS
SYSTEM
APCS A+CLASS
NO. Of TEACHER STATIONS
1One (Std.)
2Two
— —
1 Requires 0-10V dimming ballast in lighting xture.
2 Includes additional plug & play cable.
3 Adds Raise/Lower dimming switch to TLC. 3-gang switch station
consists of General/ A/V switch, Raise/Lower switch, Study Time switch.
4 WT when used with 2 Teacher Stations will control one whiteboard
from 2 locations.
DAYLIGHT ZONES
Blank None
Z1 Row nearest the
window2
Z2 2 Rows nearest
the window2
Z3 3 Rows nearest
the window2
Z4 4 Rows nearest
the window2
EXAMPLE: APCS-2-277-TLC1-02-DDZ2
A+CLASS OCCUPANCY SENSOR WITH INTELLiDAPT
DUAL TECH: PASSIVE INFRARED AND ULTRASONIC
Page 2/2 Rev. 07/31/13
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
US Patent #8,436,542 OCCUPANCY SENSOR - APCS
Test Date 7/14/00
ORDERING
When ordered as part of the APCS system, the
APCS-OS will ship with one 50’ CAT5 color coded
low voltage plug-and-play cable per occupancy
sensor (one Occupancy Sensor supplied standard,
two optional).
The full APCS system includes lighting and controls
for a typical classroom application. See the ordering
guide for APCS control; lighting selections are found
at www.aleralighting.com and are ordered as a
separate line item as part of the APCS package.
IntelliDAPT Dual Technology with
LED Indicator
Auto reset from test setting. Self-adjusting timer.
Self-adjusting ultrasonic and passive infrared
thresholds. Automatic false-on/false-o corrections.
Ultrasonic (US) output of 32kHz.Passive infrared
(PIR) dual element pyrometer and 12-element
cylindrical rugged lens. LED lamp colors provide
visual cues indicating occupancy detection method.
Red indicates infrared detection. Green indicates
ultrasonic motion.
Timer timeout
Automatic mode: 8–30 min. (self-adjusts based on
occupancy)
Test mode: 8 seconds (for an easy check at
installation)
Coverage, Power and Signal
Coverage area of approximately 2,000 square
feet. Power input 24 VDC, 33 mA . Power is
provided through A+CLASS™ low voltage color
coded plug-and-play cable; no line or low voltage
additional wiring is required for standard classroom
applications.
Output is 24 VDC active high-logic control signal
with short circuit protection
Operation
APCS-OS is for Indoor use only. Operating
temperature: 32o–104o F (0o–40o C). Relative
humidity (non-condensing): 0%–95%
Recommended MAX mounting height of 12ft.
Construction
4.5” diameter, 1.5” height (114 mm diameter, 38mm
height). 5.0 oz (142g) weight. Attractive, neutral o
white color.
Rugged casing, high-impact, injection-molded
plastic KJB ABS Cycolac (UL-945VA) ame class
rating, UV inhibitors. Mounting base provided.
Quick-To-Install TM wiring standard. Ships with
all required components when ordered as part of
the A+CLASS™ system, including but not limited
to 50’ of color coded, low voltage, plug and play
CAT5 cable for return to the A+CLASS™ CCM
(Classroom Control Module)
Certifications and Warranty
UL and cUL listed with 5 year warranty when
purchased as part of the A+CLASS™ energy
management classroom lighting and control system