B7210 Report(FCC Part 15B)

2016-04-12

: Pdf B7210 Report(Fcc Part 15B) B7210_Report(FCC_Part_15B) CertsReports 551069 ProductFiles

Open the PDF directly: View PDF PDF.
Page Count: 25

DownloadB7210 Report(FCC Part 15B)
Open PDF In BrowserView PDF
Report No.:T111221S01-D

FCC 47 CFR PART 15 SUBPART B AND ANSI C63.4:2003
IC ICES-003 Issue 4
TEST REPORT
For
IP Cam
Model : B7210
Trade Name : ZAVIO
Issued for

ZAVIO Inc.
2F, No.13, R&D Rd.II, Science Based Industrial Park,
Hsinchu, Taiwan
Issued by

Compliance Certification Services Inc.
Hsinchu Lab.
NO. 989-1 Wen Shan Rd., Shang Shan Village,
Qionglin Shiang Hsinchu County 30741, Taiwan, R.O.C
TEL: +886-3-5921698
FAX: +886-3-5921108
http://www.ccsrf.com
E-Mail : service@ccsrf.com
Issued Date: January 03, 2012

Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification
Services Inc. This document may be altered or revised by Compliance Certification Services Inc. personnel only,
and shall be noted in the revision section of the document. The client should not use it to claim product
endorsement by TAF or any government agencies. The test results of this report relate only to the tested sample
identified in this report.

Page 1 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

Revision History
Rev.

Issue Date

Revisions

Effect Page

Revised By

00

01/03/2012

Initial Issue

All Page 25

Cindy Pon

Page 2 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

TABLE OF CONTENTS
TITLE

PAGE NO.

1. TEST REPORT CERTIFICATION ................................................................................4
2. EUT DESCRIPTION .....................................................................................................5
3. DESCRIPTION OF TEST MODES ...............................................................................5
4. TEST METHODOLOGY ...............................................................................................6
5. FACILITIES AND ACCREDITATION ...........................................................................6
5.1 FACILITIES ............................................................................................................6
5.2 ACCREDITATIONS................................................................................................6
5.3 MEASUREMENT UNCERTAINTY .........................................................................7
6. SETUP OF EQUIPMENT UNDER TEST......................................................................8
7. EMISSION TEST ..........................................................................................................9
7.1 RADIATED EMISSION...........................................................................................9-16
7.2 CONDUCTED EMISSION ......................................................................................17-20
APPENDIX SETUP PHOTOS ..........................................................................................21-25

Page 3 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

1. TEST REPORT CERTIFICATION
: ZAVIO Inc.
: 2F, No.13, R&D Rd.II, Science Based Industrial Park,

Applicant
Address

Hsinchu, Taiwan
Equipment Under Test: IP Cam
: B7210
Model
Trade Name
Tested Date

: ZAVIO
: December 21, 2011 ~ January 02, 2012

APPLICABLE STANDARD
Standard

Item

Test Result

FCC Part 15 Subpart B, CLASS A
AND

Radiated Emission

PASS

Conducted Emission

PASS

ANSI C63.4:2003
IC ICES-003 Issue 4

WE HEREBY CERTIFY THAT: The above equipment has been tested by Compliance
Certification Services Inc., and found compliance with the requirements set forth in the
technical standards mentioned above. The results of testing in this report apply only to the
product/system, which was tested. Other similar equipment will not necessarily produce the
same results due to production tolerance and measurement uncertainties.

Approved by:

Reviewed by:

Sb. Lu
Sr. Engineer

Gundam Lin
Sr. Engineer

Page 4 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

2. EUT DESCRIPTION
Product Name

IP Cam

Model Number

B7210

Identify Number

T111221S01

Received Date

December 21, 2011

Power Rating

12Vdc

Test Voltage

120Vac, 60Hz

DC Power Cable Type Non-shielded cable, 1.5m (Non-detachable)
Power Port × 1, Video Out Port × 1, RJ-45 Port × 1, Micro SD
Port × 1, DI/DO Port × 2

I/O Port
Power Adapter :
No. Manufacturer
1

DVE

Model No.

Power Input

Power Output

DSA-20CA-12
120150

100-240Vac, 50/60Hz,
0.8A

12Vdc, 1.5A

Remark : For more details, please refer to the User’s manual of the EUT.

3. DESCRIPTION OF TEST MODES
1. The following test modes were scanned during the preliminary test:
No. Pre-Test Mode
1

Normal Operating / Power Adapter

2

Normal Operating / PoE Mode

2. After the preliminary scan, the following test mode was found to produce the highest
emission level.
Final Test Mode
Emission

Radiated Emission
Conducted Emission

Normal Operating / Power Adapter
Normal Operating / PoE Mode
Normal Operating / Power Adapter

Remark : Then, the above highest emission mode of the configuration of the EUT and cable was
chosen for all final test items.

Page 5 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

4. TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.4:2003
and FCC CFR 47 Part 15 Subpart B, IC ICES-003 Issue 4.

5. FACILITIES AND ACCREDITATION
5.1 FACILITIES
All measurement facilities used to collect the measurement data are located at
NO. 989-1 Wen Shan Rd., Shang Shan Village,
Qionglin Shiang Hsinchu County 30741, Taiwan, R.O.C
The sites are constructed in conformance with the requirements of ANSI C63.4:2003 and
CISPR 22. All receiving equipment conforms to CISPR 16-1-1, CISPR 16-1-2, CISPR
16-1-3, CISPR 16-1-4, CISPR 16-1-5.

5.2 ACCREDITATIONS
Our laboratories are accredited and approved by the following approval agencies
according to ISO/IEC 17025.
Taiwan

TAF

The measuring facility of laboratories has been authorized or registered by the following
approval agencies.
Canada
Japan
Taiwan
USA

INDUSTRY CANADA
VCCI
BSMI
FCC MRA

Copies of granted accreditation certificates are available for downloading from our web
site, http:///www.ccsrf.com

Page 6 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

5.3 MEASUREMENT UNCERTAINTY
The following table is for the measurement uncertainty, which is calculated as per the
document CISPR 16-4-2.
PARAMETER

UNCERTAINTY

Open Area Test Site (OATS No.3) /
Radiated Emission, 30 to 1000 MHz
Semi Anechoic Chamber (966 Chamber_B) /
Radiated Emission, 30 to 1000 MHz

+/- 3.7199
+/- 3.5189

Semi Anechoic Chamber (966 Chamber_B) /
Radiated Emission, 1 to 18GHz

+/- 2.5164

Semi Anechoic Chamber (966 Chamber_B) /
Radiated Emission, 18 to 26 GHz

+/- 2.4967

Semi Anechoic Chamber (966 Chamber_B) /
Radiated Emission, 26 to 40 GHz
Conducted Emission (Mains Terminals),
9kHz to 30MHz

+/- 2.7655
+/- 1.5923

This uncertainty represents an expanded uncertainty expressed at approximately the
95% confidence level using a coverage factor of k=2.
Consistent with industry standard (e.g. CISPR 22: 2006, clause 11, Measurement
Uncertainty) determining compliance with the limits shall be base on the results of the
compliance measurement. Consequently the measure emissions being less than the
maximum allowed emission result in this be a compliant test or passing test.
The acceptable measurement uncertainty value without requiring revision of the
compliance statement is base on conducted and radiated emissions being less than
UCISPR which is 3.6dB and 5.2dB respectively. CCS values (called ULab in CISPR 16-4-2)
is less than UCISPR as shown in the table above. Therefore, MU need not be considered
for compliance.

Page 7 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

6. SETUP OF EQUIPMENT UNDER TEST
SUPPORT EQUIPMENT
No.

Product

Manufacturer

Model No.

Serial No.

FCC ID

1

Notebook PC

HP

ProBook 4421s

CNF03242PM

-----

2

LCD Monitor

DELL

2407WFPb

CN-0FC255-466336CP-06JS

-----

3

LCD Monitor

ViewSonic

VS10563-1M

PQ3053205218

DoC

4

8-poer fast
Ethernet PoE
Switch

Air Live

POE-FSH804

POEF80411700328

-----

5

Micro SD Card

SanDisk

2GB

-----

-----

No. Signal Cable Description
1

Non-shielded RJ45 cable, 10m × 1

2

Non-shielded Video cable, 3m × 1

SETUP DIAGRAM FOR TESTS
EUT & peripherals setup diagram is shown in appendix setup photos.
EUT OPERATING CONDITION
All the equipment/cables were placed in the worst-case configuration to maximize the
emission during the test. Grounding was established in accordance with the manufacturer’s
requirements and conditions for the intended use.
Normal Operating
Power Adapter:
1. Setup whole system for test as shown on diagram
2. Notebook PC ping 192.168.1.149 to EUT
3. Video output to LCD MONITOR.
4. All of the functions are under run.
5. Start test.
PoE Mode:
1. Remove AC power adapter from EUT.
2. RJ-45 cable linking to PoE ethernet switch.
3. Notebook PC ping 192.168.1.149 to EUT with PoE ethernet switch.
4. Video output to LCD monitor.
5. All of the functions are under run.
6. Start test.
Page 8 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

7. EMISSION TEST
7.1 RADIATED EMISSION
LIMITS
(1) For Frequency Below 1GHz
47 CFR Part 15 Subpart B Section 15.109 (a) (b)
Class A
Frequency
Field
Field
Field
Distance
(MHz)
Strength
Strength
Strength
(meters)
(µV/m)
(µV/m)
(dBµV/m)
30 - 88
90
39.1
10
100

Class B
Field
Strength
(dBµV/m)
40.0

Distance
(meters)
3

88 - 216

150

43.5

10

150

43.5

3

216 - 960

210

46.4

10

200

46.0

3

Above 960

300

49.5

10

500

54.0

3

CISPR 22 (According to 47 CFR Part 15 Subpart B Section 15.109 (g))
Frequency
Distance
Field Strengths (dBµV/m)
(MHz)
(meters)
Class A
Class B
30 - 230
40
30
10
230 - 1000

47

37

10

(2) For Frequency Above 1GHz (According to 47 CFR Part 15 Subpart B Section 15.109)
Field Strength (dBµV/m)
Distance
Frequency
Class A
Class B
(meters)
(GHz)
Peak
Average
Peak
Average
Above 1GHz

80

60

74

54

3

(3) Frequency Range of Radiated Measurement (For unintentional radiators)
Highest frequency generated or Upper
frequency of measurement used in the device
Range (MHz)
or on which the device operates or tunes (MHz)
Below 1.705
30
1.705 – 108

1000

108 – 500

2000

500 – 1000

5000

Above 1000

5th harmonic of the highest frequency
or 40GHz, whichever is lower

Page 9 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

TEST EQUIPMENT
Radiated Emission below 1GHz / OATS3
Name of Equipment

Manufacturer

Model

Serial Number

Calibration
Due

Bi-log Antenna

SCHAFFER

CBL6112B

2696

10/03/2012

EMI Test Receiver

ROHDE & SCHWARZ

ESCI

101131

01/13/2012

Serial Number

Calibration
Due

Remark: Each piece of equipment is scheduled for calibration once a year.

Radiated Emission above 1GHz / 966Chamber_B
Name of Equipment

Manufacture

Model

Spectrum Analyzer

Agilent

E4446A

EMI Receiver

ROHDE & SCHWARZ

ESCS 30

826547/004

10/27/2012

Broadband Hybrid
Bi-Log Antenna

Sunol Sciences

JB1

A100209-4

10/05/2012

Double-Ridged
Waveguide Horn

ETS-LINDGREN

3117

00078733

12/06/2012

Pre-Amplifier

Agilent

8447D

2944A10052 07/19/2012

Pre-Amplifier

Agilent

8449B

3008A01916 09/18/2012

Notch Filters Band
Reject

Micro-Tronics

BRM05702-01

MY43360132 06/19/2012

026

N.C.R

Remark: 1. Each piece of equipment is scheduled for calibration once a year.
2. N.C.R = No Calibration Request.

Page 10 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

TEST SETUP
The diagram below shows the test setup that is utilized to make the measurements for
emission from below 1GHz.
Antenna
Tower

10m

Bi-log
Antenna

EUT
1~4m

EMI Test
Receiver
Turntable

1m

0.8m

Coaxial Cable

Reference ground plane

The diagram below shows the test setup that is utilized to make the measurements for
emission above 1GHz.
Antenna
Tower

Horn
Antenna

3m
EUT
1~4m

Spectrum
Analyzer
Turntable

Coaxial Cable
0.8m

1m
Pre-amp

Reference ground plane

Page 11 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

TEST PROCEDURE
The basic test procedure was in accordance with ANSI C63.4:2003.
The devices under test were placed on a rotatable table top 0.8 meter above ground. The
table was rotated 360 degrees to determine the position of the highest radiation. EUT is
set 3 or 10m meters from the interference receiving antenna which is mounted on the top
of a variable height mast. The antenna height is varied between one meter and four
meters above ground to find the maximum value of the field strength both horizontal
polarization and vertical polarization of the antenna are set to make the measurement.
Note:
1. The bandwidth setting on the E.M.I. meter (EMI TEST RECEIVER) is 120 KHz. The levels are
Quasi-Peak value readings. The frequency spectrum from 30MHz to 1000MHz was
investigated.
2. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 1 MHz for
Peak detection and frequency above 1GHz.
3. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth
is 10 Hz for Average detection (AV) at frequency above 1GHz.

Page 12 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

TEST RESULTS
Below 1 GHz
Product Name

IP Cam

Test By

Tom Deng

Test Model

B7210
Normal Operating /
Power Adapter

Test Date

2011/12/27

Temp. & Humidity

17°C, 65%

Test Mode

OATS3 at 10Meter / Horizontal
Frequency
(MHz)

Antenna Cable
Meter
Emission Margin
Limits
Azimuth Height
Factor
Loss Reading
Level
Limit
Remark
(dBµV/m)
(°)
(cm)
(dB/m)
(dB)
(dBµV)
(dBµV/m) (dB)

125.11

11.82

2.08

2.95

40.00

16.85

-23.15

130

400

QP

160.03

9.94

2.50

5.12

40.00

17.56

-22.44

146

150

QP

250.65

12.77

3.45

1.41

47.00

17.63

-29.37

139

150

QP

335.48

14.09

4.11

6.14

47.00

24.34

-22.66

290

250

QP

398.26

15.64

4.68

11.78

47.00

32.10

-14.90

223

200

QP

975.36

21.41

9.20

1.32

47.00

31.93

-15.07

84

200

QP

OATS3 at 10Meter / Vertical
Frequency
(MHz)

Antenna Cable
Meter
Emission Margin
Limits
Azimuth Height
Factor
Loss Reading
Level
Limit
Remark
(dBµV/m)
(°)
(cm)
(dB/m)
(dB)
(dBµV)
(dBµV/m) (dB)

32.81

15.85

0.96

10.16

40.00

26.97

-13.03

30

100

QP

125.11

11.82

2.08

8.90

40.00

22.80

-17.20

360

100

QP

160.03

9.94

2.50

12.59

40.00

25.03

-14.97

188

100

QP

398.26

15.64

4.68

12.43

47.00

32.75

-14.25

107

100

QP

875.56

20.19

8.60

2.25

47.00

31.04

-15.96

34

200

QP

975.36

21.41

9.20

1.71

47.00

32.32

-14.68

67

150

QP

Remark:
1. Quasi-peak test would be performed if the peak result were greater than the quasi-peak limit.
2. Data of measurement within this frequency range shown " --- " in the table above means the reading of
emissions are attenuated more than 20dB below the permissible limits or the field strength is too small
to be measured.
3. Emission Level (dBµV/m) = Antenna Factor (dB/m) + Cable Loss (dB) + Meter Reading (dBµV)
4. Margin (dB) = Emission Level (dBuV/m) - Quasi-peak limit (dBuV/m)

Page 13 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

Product Name

IP Cam

Test By

Tom Deng

Test Model

B7210
Normal Operating /
PoE Mode

Test Date

2011/12/27

Temp. & Humidity

17°C, 65%

Test Mode

OATS3 at 10Meter / Horizontal
Frequency
(MHz)

Antenna Cable
Meter
Emission Margin
Limits
Azimuth Height
Factor
Loss Reading
Level
Limit
Remark
(dBµV/m)
(°)
(cm)
(dB/m)
(dB)
(dBµV)
(dBµV/m) (dB)

75.31

6.93

1.51

7.40

40.00

15.83

-24.17

130

300

QP

125.11

11.82

2.08

8.56

40.00

22.46

-17.54

146

100

QP

151.49

10.69

2.41

15.38

40.00

28.49

-11.51

139

150

QP

398.26

15.64

4.68

19.56

47.00

39.88

-7.12

290

200

QP

485.30

17.28

5.48

2.21

47.00

24.97

-22.03

223

100

QP

534.03

18.24

5.94

1.18

47.00

25.36

-21.64

84

200

QP

OATS3 at 10Meter / Vertical
Frequency
(MHz)

Emission Margin
Antenna Cable
Meter
Azimuth Height
Limits
Level
Limit
Factor
Loss Reading
Remark
(°)
(cm)
(dBµV/m)
(dBµV/m) (dB)
(dB/m)
(dB)
(dBµV)

39.25

14.48

1.09

13.68

40.00

29.24

-10.76

236

100

QP

75.19

6.92

1.50

26.85

40.00

35.27

-4.73

160

100

QP

125.11

11.82

2.08

18.70

40.00

32.60

-7.40

32

100

QP

150.81

10.75

2.41

20.63

40.00

33.79

-6.21

68

100

QP

398.26

15.64

4.68

18.44

47.00

38.76

-8.24

65

150

QP

521.28

17.96

5.81

3.38

47.00

27.15

-19.85

73

150

QP

Remark:
1. Quasi-peak test would be performed if the peak result were greater than the quasi-peak limit.
2. Data of measurement within this frequency range shown " --- " in the table above means the reading of
emissions are attenuated more than 20dB below the permissible limits or the field strength is too small
to be measured.
3. Emission Level (dBµV/m) = Antenna Factor (dB/m) + Cable Loss (dB) + Meter Reading (dBµV)
4. Margin (dB) = Emission Level (dBuV/m) - Quasi-peak limit (dBuV/m)

Page 14 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

Above 1 GHz
Product Name

IP Cam

Test By

Tom Deng

Test Model

B7210
Normal Operating /
Power Adapter

Test Date

2011/12/26

Temp. & Humidity

17°C, 61%

Test Mode

966 Chamber_B at 3Meter / Horizontal
Frequency
(MHz)

Reading- Reading- Correction
Result-PK Result-AV Limit-PK Limit-AV Margin Azimuth Height
Remark
Factor
AV
PK
(dBuV/m) (dBuV/m) (dBuV/m) (dBuV/m) (dB)
(°)
(cm)
(dB/m)
(dBuV) (dBuV)

1070.00

49.45

---

-3.65

45.79

---

80.00

60.00

-14.21

139.80 100.00

Peak

1175.00

48.20

---

-3.32

44.89

---

80.00

60.00

-15.11

25.00

100.00

Peak

1600.00

45.09

---

-1.37

43.72

---

80.00

60.00

-16.28

11.20

200.00

Peak

2645.00

43.27

---

4.31

47.58

---

80.00

60.00

-12.42

342.00 200.00

Peak

4205.00

40.94

---

7.69

48.63

---

80.00

60.00

-11.37

153.60 200.00

Peak

4835.00

40.95

---

9.51

50.46

---

80.00

60.00

-9.54

342.00 100.00

Peak

966 Chamber_B at 3Meter / Vertical
Frequency
(MHz)

Reading- Reading- Correction
Result-PK Result-AV Limit-PK Limit-AV Margin Azimuth Height
Remark
Factor
AV
PK
(dBuV/m) (dBuV/m) (dBuV/m) (dBuV/m) (dB)
(°)
(cm)
(dB/m)
(dBuV) (dBuV)

1050.00

49.88

---

-3.72

46.16

---

80.00

60.00

-13.84

222.40 100.00

Peak

1175.00

48.07

---

-3.32

44.75

---

80.00

60.00

-15.25

206.30 100.00

Peak

1600.00

45.01

---

-1.37

43.64

---

80.00

60.00

-16.36

315.90 100.00

Peak

2760.00

42.78

---

4.67

47.45

---

80.00

60.00

-12.55

263.80 200.00

Peak

3075.00

42.65

---

5.49

48.14

---

80.00

60.00

-11.86

206.10 200.00

Peak

5855.00

39.30

---

11.50

50.80

---

80.00

60.00

-9.20

263.10 100.00

Peak

Remark:
1. Average test would be performed if the peak result were greater than the average limit.
2. Data of measurement within this frequency range shown “ --- ” in the table above means the reading of emissions
are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured.
3. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with “ N/A ” remark, if no
specific emissions from the EUT are recorded (ie: margin>20dB from the applicable limit) and considered that's
already beyond the background noise floor.
4. Result = Reading + Correction Factor
Margin = Result – Limit
Remark Peak = Result(PK) – Limit(AV)
Remark AVG = Result(AV) – Limit(AV)

Page 15 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

Product Name

IP Cam

Test By

Tom Deng

Test Model

B7210
Normal Operating /
PoE Mode

Test Date

2011/12/26

Temp. & Humidity

17°C, 61%

Test Mode

966 Chamber_B at 3Meter / Horizontal
Frequency
(MHz)

Reading- Reading- Correction
Result-PK Result-AV Limit-PK Limit-AV Margin Azimuth Height
Remark
Factor
AV
PK
(dBuV/m) (dBuV/m) (dBuV/m) (dBuV/m) (dB)
(°)
(cm)
(dB/m)
(dBuV) (dBuV)

1060.00

49.30

---

-3.69

45.61

---

80.00

60.00

-14.39

146.60 200.00

Peak

1175.00

46.56

---

-3.32

43.24

---

80.00

60.00

-16.76

263.80 100.00

Peak

1875.00

44.32

---

1.10

45.41

---

80.00

60.00

-14.59

351.30 100.00

Peak

2240.00

43.62

---

3.01

46.63

---

80.00

60.00

-13.37

91.60

100.00

Peak

2970.00

42.47

---

5.32

47.79

---

80.00

60.00

-12.21

54.80

200.00

Peak

4130.00

41.54

---

7.44

48.98

---

80.00

60.00

-11.02

224.90 100.00

Peak

5960.00

40.41

---

11.73

52.14

---

80.00

60.00

-7.86

31.80

Peak

200.00

966 Chamber_B at 3Meter / Vertical
Frequency
(MHz)

Reading- Reading- Correction
Result-PK Result-AV Limit-PK Limit-AV Margin Azimuth Height
Remark
Factor
AV
PK
(dBuV/m) (dBuV/m) (dBuV/m) (dBuV/m) (dB)
(°)
(cm)
(dB/m)
(dBuV) (dBuV)

1060.00

52.18

---

-3.69

48.49

---

80.00

60.00

-11.51

149.10 200.00

Peak

1175.00

46.93

---

-3.32

43.61

---

80.00

60.00

-16.39

128.40 100.00

Peak

1600.00

45.82

---

-1.37

44.45

---

80.00

60.00

-15.55

18.20

100.00

Peak

2145.00

43.51

---

2.70

46.21

---

80.00

60.00

-13.79

247.70 200.00

Peak

3130.00

42.60

---

5.55

48.16

---

80.00

60.00

-11.84

5550.00

40.30

---

10.86

51.15

---

80.00

60.00

-8.85

1.30

200.00

Peak

229.40 100.00

Peak

Remark:
1. Average test would be performed if the peak result were greater than the average limit.
2. Data of measurement within this frequency range shown “ --- ” in the table above means the reading of emissions
are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured.
3. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with “ N/A ” remark, if no
specific emissions from the EUT are recorded (ie: margin>20dB from the applicable limit) and considered that's
already beyond the background noise floor.
4. Result = Reading + Correction Factor
Margin = Result – Limit
Remark Peak = Result(PK) – Limit(AV)
Remark AVG = Result(AV) – Limit(AV)

Page 16 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

7.2 CONDUCTED EMISSION
LIMITS
Voltage Limits (dBµV)

Frequency Range
(MHz)

Class A

Class B

Quasi-peak

Average

Quasi-peak

Average

0.15 - 0.50

79

66

66 - 56*

56 - 46*

0.50 - 5.00

73

60

56

46

5.00 - 30.0

73

60

60

50

Remark: (1) The limit decreases linearly with logarithm of the frequency in the range 0.15 MHz to
0.50 MHz.
(2) The lower limit shall apply at the transition frequency.
(3) * Decreasing linearly with the logarithm of the frequency.

TEST EQUIPMENT
Name of Equipment

Manufacturer

Model

Serial Number

Calibration
Due

L.I.S.N

SCHWARZBECK

NSLK 8127

8127-465

08/09/2012

L.I.S.N

SCHWARZBECK

NSLK 8127

8127-473

03/14/2012

EMI Receiver

ROHDE & SCHWARZ

ESCS 30

835418/008

10/20/2012

Pulse Limiter

ROHDE & SCHWARZ

ESH3-Z2

100117

09/14/2012

Remark: Each piece of equipment is scheduled for calibration once a year.

TEST SETUP

Page 17 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

Powerline of
Peripherals
120VAC
/ 60Hz

Powerline of
EUT

L.I.S.N.

L.I.S.N.

120VAC
/ 60Hz

EUT & Peripherals
120VAC
/ 60Hz

Isolate Transformer

EMI Test Receiver

TEST PROCEDURE
The basic test procedure was in accordance with ANSI C63.4:2003.
The test procedure is performed in a 4m × 3m × 2.4m (L×W×H) shielded room.
The EUT along with its peripherals were placed on a 1.0m (W) × 1.5m (L) and 0.8m in
height wooden table and the EUT was adjusted to maintain a 0.4 meter space from a
vertical reference plane.
The EUT was connected to power mains through a line impedance stabilization network
(LISN) which provides 50 ohm coupling impedance for measuring instrument and the
chassis ground was bounded to the horizontal ground plane of shielded room. All
peripherals were connected to the second LISN and the chassis ground also bounded to
the horizontal ground plane of shielded room.
The EUT was located so that the distance between the boundary of the EUT and the
closest surface of the LISN is 0.8 m. Where a mains flexible cord was provided by the
manufacturer shall be 1 m long, or if in excess of 1 m, the excess cable was folded back
and forth as far as possible so as to form a bundle not exceeding 0.4 m in length.

Page 18 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

TEST RESULTS
Product Name

IP Cam

Test By

Tom Deng

Test Model

B7210
Normal Operating /
Power Adapter

Test Date

2011/12/12

Temp. & Humidity

24°C, 65%

Test Mode
LINE

Remark:
1. Correction Factor = Insertion loss + Cable loss
2. Emission level = Reading Value + Correction factor
3. Margin value = Emission level – Limit value

Page 19 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

Product Name

IP Cam

Test By

Tom Deng

Test Model

B7210
Normal Operating /
Power Adapter

Test Date

2011/12/12

Temp. & Humidity

24°C, 65%

Test Mode
NEUTRAL

Remark:
1. Correction Factor = Insertion loss + Cable loss
2. Emission level = Reading Value + Correction factor
3. Margin value = Emission level – Limit value

Page 20 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

APPENDIX SETUP PHOTOS
RADIATED EMISSION SETUP
Below 1 GHz
Power Adapter

Page 21 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

PoE Mode

Page 22 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

Above 1 GHz
Power Adapter

Page 23 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

PoE Mode

Page 24 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.

Report No.:T111221S01-D

CONDUCTED EMISSION SETUP

Page 25 / 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
Page Count                      : 25
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:27aba77f-8766-42ff-90af-92c3ba4f14a2
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Modify Date                     : 2012:01:10 14:37:58+08:00
Create Date                     : 2012:01:10 14:33:56+08:00
Metadata Date                   : 2012:01:10 14:37:58+08:00
Document ID                     : uuid:b3d5fdd1-6096-4699-a5c0-6b89c0827b2d
Format                          : application/pdf
Title                           : untitled
EXIF Metadata provided by EXIF.tools

Navigation menu