ANNEX A - PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (NORMATIVE) (This annex is part of this Standard and is required for its use.) BACnet Protocol Implementation Conformance Statement Date: December 1, 2014 Vendor Name: Electro Industries / GaugeTech Product Name: Shark 50B, Shark 100B Product Model Number: E170102, E141102 Application Software Version: v6.01 Firmware Revision: v2.02 BACnet Protocol Revision: 9 Product Description: The Shark 50B/100B is an electric meter compatible with an existing BACnet Compliant Building Automation System. The Ethernet connection conforms to the BACnet/IP standard which is complemented by many network friendly features such as password-protected web-server browser-accessible based setup screens. Once a user is logged in configuration is easy. Defaults are well vetted. Once connected to the Building Automation Network, a BACnet client like the Cimetrics BACnet Explorer or OPC server, can look at the Shark 50B/100B meters as BACnet Devices. Meter data exposed to the BACnet network includes Power, Energy, Demand, MaxDemand, Power_Factor, Flow, Consumption, Current, Voltage, and Phase. BACnet Standardized Device Profile (Annex L): BACnet Operator Workstation (B-OWS) BACnet Advanced Operator Workstation (B-AWS) BACnet Operator Display (B-OD) BACnet Building Controller (B-BC) BACnet Advanced Application Controller (B-AAC) BACnet Application Specific Controller (B-ASC) BACnet Smart Sensor (B-SS) BACnet Smart Actuator (B-SA) List all BACnet Interoperability Building Blocks Supported (Annex K): DS-RP-B, DS-RPM-B, DS-WP-B, DM-DDB-B Segmentation Capability: Able to transmit segmented messages Able to receive segmented messages Window Size Window Size Standard Object Types Supported: An object type is supported if it may be present in the device. For each standard Object Type supported provide the following data: 1) Whether objects of this type are dynamically creatable using the CreateObject service - NO 2) Whether objects of this type are dynamically deletable using the DeleteObject service - NO 3) List of the optional properties supported – see below E141741 Rev A 12/17/14 Page 1 of 3 4) List of all properties that are writable where not otherwise required by this standard – n/a 5) List of all properties that are conditionally writable where not otherwise required by this standard –n/a 6) List of proprietary properties and for each its property identifier, datatype, and meaning –n/a 7) List of any property range restrictions – n/a Object Type Analog Input Optional Properties Supported Description, Device_Type, Reliability, Min_Pres_Value Analog Value Description Binary Input Device Description, Device_Type, Reliability, Inactive_Text, Active_Text, Change_of_State_Time, Change_of_State_Count, Time_of_State_Count_Reset, Description Data Link Layer Options: BACnet IP, (Annex J) BACnet IP, (Annex J), Foreign Device ISO 8802-3, Ethernet (Clause 7) ATA 878.1, 2.5 Mb. ARCNET (Clause 8) ATA 878.1, EIA-485 ARCNET (Clause 8), baud rate(s) ____________ MS/TP master (Clause 9), baud rate(s): MS/TP slave (Clause 9), baud rate(s): Point-To-Point, EIA 232 (Clause 10), baud rate(s): Point-To-Point, modem, (Clause 10), baud rate(s): LonTalk, (Clause 11), medium: __________ BACnet/ZigBee (ANNEX O) Other: Device Address Binding: Is static device binding supported? (This is currently necessary for two-way communication with MS/TP slaves and certain other devices.) Yes No Networking Options: Router, Clause 6 - List all routing configurations, e.g., ARCNET-Ethernet, Ethernet-MS/TP, etc. Annex H, BACnet Tunneling Router over IP E141741 Rev A 12/17/14 Page 2 of 3 BACnet/IP Broadcast Management Device (BBMD) Does the BBMD support registrations by Foreign Devices? Does the BBMD support network address translation? Yes No Yes No Character Sets Supported: Indicating support for multiple character sets does not imply that they can all be supported simultaneously. ISO 10646 (UTF-8) ISO 10646 (UCS-2) IBM/MicrosoftDBCS ISO 10646 (UCS-4) ISO 8859-1 JIS X 0208 If this product is a communication gateway, describe the types of non-BACnet equipment/networks(s) that the gateway supports: Modbus/RTU internally - direct internal communication only. Network Security Options: Non-secure Device - is capable of operating without BACnet Network Security Secure Device - is capable of using BACnet Network Security (NS-SD BIBB) Multiple Application-Specific Keys Supports encryption (NS-ED BIBB) E141741 Rev A 12/17/14 Page 3 of 3
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Dave Robin Company : Automated Logic Corporation Create Date : 2014:12:17 07:56:33-05:00 Modify Date : 2014:12:17 07:56:36-05:00 Source Modified : D:20141217125528 Subject : Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2014:12:17 07:56:36-05:00 Creator Tool : Acrobat PDFMaker 10.0 for Word Document ID : uuid:1a078dce-0ebd-432e-91d3-ee185052927b Instance ID : uuid:c4f18b34-d5a5-4666-bf7b-2c5f84468361 Format : application/pdf Title : Description : Creator : Dave Robin Producer : Adobe PDF Library 10.0 Keywords : Page Layout : OneColumn Page Count : 3EXIF Metadata provided by EXIF.tools